MASTER SIGN PROGRAM JULY 18, 2025
Attachment 4
SIGN MATRIX
SIGN TYPE
1 MONUMENT SIGN
TOTAL SIGN AREA ALLOWED BY CITY SIGN CODE, FOR OVERALL PROJECT
SIGN AREA PER SIGN TYPE SIGN CODE DEVIATION
TO EXCEED THE MAXIMUM ALLOWED SIGN AREA
FOR ALL BUILDINGS AND PROJECT SITE AS A WHOLE.
3,044 SQUARE FEET
BUILDING BUSINESS FACADE (FRONTAGE PER BUILDING) TOTAL ALLOWED SIGN AREA PER BUILDING* ONE
2 ENTRY PORTAL SIGNAGE
3 VEHICULAR DIRECTIONAL SIGN
QUANTITY SIGN AREA (PER SIGN)
-
4 BUILDING ADDRESS SIGN
5 TENANT CANOPY SIGN
6 TENANT ON-BUILDING SIGN
7 TENANT GRAPHIC AREA
UNIT IDENTIFICATION SIGN
TWO
NINE
TWO PER BUILDING (OR AS REQUIRED)
ONE SIGN PER UNIT ENTRY
MAXIMUM OF TWO SIGNS PER ELEVATION
MAXIMUM FOUR SIGNS PER BUILDING
ONE SIGN PER UNIT ENTRY
ONE SIGN PER UNIT ENTRY
180 SQUARE FEET
64 SQUARE FEET
12.5 SQUARE FEET
10 SQUARE FEET OR AS REQUIRED
25 SQUARE FEET MAX
75 SQUARE FEET MAX
9 SQUARE FEET TOTAL
8 5 SQUARE FEET TOTAL
LUMINAR BUSINESS PARK - MASTER SIGN PROGRAM PAGE 1
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
266'
324'
168'
333'
331'
318'
456'
178'
247'
169'
254'
266 SQUARE FEET
324 SQUARE FEET
168 SQUARE FEET
333 SQUARE FEET
331 SQUARE FEET
318 SQUARE FEET
456 SQUARE FEET
178 SQUARE FEET
247 SQUARE FEET
169 SQUARE FEET
254 SQUARE FEET
*1 SQ.FT. OF SIGN ALLOWED FOR EACH LINEAL
FOOT OF ALL BUSINESS FAÇADE
REQUESTED BUILDING SIGNAGE = 5,407.5 SF
REQUESTED SITE SIGNAGE = 412.5 SF
TOTAL REQUESTED PROJECT SIGNAGE = 5,819.5 SF
SITE SIGNAGE PLAN
LEGEND QTY.
KEY
SIGN TYPE 1.1 LOCATION
1 2
3 MONUMENT SIGN
ENTRY PORTAL SIGNAGE
VEHICULAR DIRECTIONAL SIGN
1 2
9 1.1
2.1 3.1
3.2 3.3
3.4 3.9
3.8 3.5
3.6 3.7
2.2 A
PLAN
NOT TO SCALE
LUMINAR BUSINESS PARK - MASTER SIGN PROGRAM PAGE 2
MURAL WALL LOCATION
MURAL OPPORTUNITIES
PLAN
NOT TO SCALE
LUMINAR BUSINESS PARK - MASTER SIGN PROGRAM PAGE 4
*MAXIMUM (2) MURALS PER BUILDING
SATIN PAINTED FABRICATED ALUMINUM
SIGN STRUCTURE WITH INTERNAL FRAMING
AND CONCRETE FOOTING BELOW GRADE
PER SIGN CONTRACTOR’S STRUCTURAL
ENGINEERING CALCULATIONS.
DESIGN NOTES
1 LUMINAR BUSINESS PARK - MASTER SIGN PROGRAM PAGE 5
SIGN TYPE 1 - MONUMENT SIGN
SIGNS TO BE ILLUMINATED WITH LOW PROFILE
LED LIGHT FIXTURES CONCEALED IN
LANDSCAPE AREA.
ILLUMINATION
SIGN TO BE INSTALLED IN LANDSCAPE AREA
ON PRIVATE PROPERTY AND SHALL BE SETBACK
A MINIMUM OF 10 FEET FROM PUBLIC STREET
CURB, 2 FEET FROM BACK OF SIDEWALK,
OUTSIDE ANY REQUIRED SITE DISTANCE
TRIANGLES, AND A MINIMUM OF 100 FEET
AWAY FROM ANOTHER GROUND SIGN.
LOCATION
1 QUANTITY
64 SQARE FEET
MAXIMUM SQUARE FOOTAGE
1-11 Via Farrona
ELEVATION VIEWS
SCALE: 3/8”=1’-0”
6'-0" MAX.
10'-8"
20" 5" 8"
FRONT VIEW END VIEW
LUMINAR BUSINESS PARK - MASTER SIGN PROGRAM PAGE 6
END VIEW FRONT VIEW
SATIN PAINTED FABRICATED ALUMINUM
SYMBOL AND LTTERS PIN MOUNTED 1/4”
OFF WALL SURFACE WITH STAINLESS STEEL
HARDWARE PER SIGN CONTRACTOR’S
STRUCTURAL ENGINEERING CALCULATIONS.
DESIGN NOTES
2 SIGN TYPE 2 - ENTRY PORTAL SIGNAGE
LETTERS TO BE HALO-ILLUMINATED AND
SYMBOL TO INTERNALLY FACE ILLUMINATED
WITH LED LIGHTING.
ALTERNATE: LETTERING AND SYMBOL TO BE
SPOT ILLUMINATED WITH LOW PROFILE LED
LIGHT FIXTURES CONCEALED IN LANDSCAPE
AREA.
ILLUMINATION
SIGNAGE TO BE INSTALLED ON LANDSCAPE
WALL (BY OTHERS) AS SHOWN.
LOCATION
2 - ONE PER ENTRY
QUANTITY
104 SQARE FEET
MAXIMUM SQUARE FOOTAGE
TYPICAL ELEVATION VIEWS
SCALE: 1/4”=1’-0”
PORTAL WALL - RENDERING VIEW
15'-6"+/-
8'-8"
20"
5"
3'-8" MAX
LUMINAR BUSINESS PARK - MASTER SIGN PROGRAM PAGE 7
1-4
5-11
5'-0"
2'-6"
SATIN PAINTED FABRICATED ALUMINUM
SIGN STRUCTURE WITH INTERNAL FRAMING
AND CONCRETE FOOTING BELOW GRADE
PER SIGN CONTRACTOR’S STRUCTURAL
ENGINEERING CALCULATIONS.
DESIGN NOTES
SIGN TYPE 3 - VEHICULAR DIRECTIONAL
SIGNS TO BE ILLUMINATED WITH LOW PROFILE
LED LIGHT FIXTURES CONCEALED IN
LANDSCAPE AREA.
ILLUMINATION
SIGN TO BE INSTALLED IN LANDSCAPE AREA
ON PRIVATE PROPERTY AND SHALL BE SETBACK
A MINIMUM OF 10 FEET FROM PUBLIC STREET
CURB, 2 FEET FROM BACK OF SIDEWALK,
OUTSIDE ANY REQUIRED SITE DISTANCE
TRIANGLES, AND A MINIMUM OF 100 FEET
AWAY FROM ANOTHER GROUND SIGN.
LOCATION
9 QUANTITY
12.5 SQARE FEET
MAXIMUM SQUARE FOOTAGE
FRONT (TYPICAL) RIGHT SIDE
3 ELEVATION VIEWS
SCALE: 3/8”=1’-0”
LEFT SIDE
TENANT NAME TENANT NAME TENANT NAME TENANT NAME TENANT NAME TENANT NAME TENANT NAME 2 TENANT NAME
TYPICAL BUILDING SIGNAGE
SCALE: NTS
TENANT NAME
TENANT NAME
TYPICALMURAL OPPORTUNITY
LUMINAR BUSINESS PARK - MASTER SIGN PROGRAM PAGE 8
TYPICAL BUILDING ELEVATIONS W/ SIGNAGE
TENANT NAME
BUILDING ADDRESS
MINIMUM 2 PER BUILDING OR AS REQUIRED
10 SQUARE FEET OR AS REQUIRED
4 TENANT GRAPHIC AREA
ONE SIGN PER UNIT ENTRY
9 SQUARE FEET TOTAL
7 TYPICAL BUILDING SIGNAGE - PARTIAL ELEVATION VIEW
SCALE: 3/16”=1’-0”
TENANT NAME
2 F
2 TENANT CANOPY SIGNAGE
ONE SIGN PER UNIT ENTRY - 18” MAX LETTER HEIGHT
25 SQUARE FEET MAX.
5 3 FT SQ
TENANT
GRAPHIC
AREA
G
2 TENANT NAME
8 UNIT IDENTIFICATION
ONE SIGN PER UNIT ENTRY
5 SQUARE FEET TOTAL
LUMINAR BUSINESS PARK - MASTER SIGN PROGRAM PAGE 9
TYPICAL BUILDING SIGNAGE
6 TENANT ON-BUILDING SIGN
(RESERVED FOR MAJOR TENANTS THAT OCCUPY LARGE SIZE / CORNER UNITS.
SIGN TO BE USED IN LIEU OF CANOPY SIGN, SUBJECT TO OWNERSHIP APPROVAL)
MAXIMUM OF TWO SIGNS PER ELEVATION
MAXIMUM FOUR SIGNS PER BUILDING
32” MAX LETTER HEIGHT
75 SQUARE FEET MAX.
DESIGN ALL BUILDING SIGNAGE TO BE NON
ILLUMINATED SATIN PAINTED FLAT CUT OUT 1/2”
THICK ALUMINUM LETTERS/NUMBERS PIN OR BASE
MOUNTED AS SHOWN WITH STAINLESS STEEL
HARDWARE PER SIGN CONTRACTOR’S STRUCTURAL
ENGINEERING CALCULATIONS.
DESIGN NOTES
SIGNS TO BE NON-ILLUMINATED.
ILLUMINATION