COUNCIL AGENDA:
FILE:
3/4/25
25-182
ITEM: 10.1(a)
CITY COUNCIL STAFF REPORT
File No. C23-115, CP24-001 & ER23-250
Applicant: Sunbelt Rentals, Inc
Location West corner of Hayes Avenue and Blossom Hill Road ramp (15 Cottle Road) (APN 690-02-003)
Existing Zoning IP Industrial Park
Proposed Zoning LI Light Industrial
General Plan Land Use
Designation
LI Light Industrial
Council District 2
Historic Resource None
Annexation Date: August 30,1970 (Oak Grove No. 36)
CEQA: Exemption per CEQA Guidelines Section 15303(c) for New Construction or Conversion of Small Structures
APPLICATION SUMMARY:
Conforming Rezoning of an approximately 0.94-gross-acre site from the IP Industrial Park to the LI Light Industrial Zoning District and a Conditional Use Permit to allow the demolition of an existing approximately 1,638-square-foot building for the construction of an approximately 5,000-square-foot building to support construction equipment sale and lease use on site, and the reconfiguration of the layout of the site.
RECOMMENDATION:
Staff recommends that the City Council:
1. Consider the exemption in accordance with the California Environmental Quality Act (CEQA) Guidelines Section 15303(c) for New Construction or Conversion of Small Structures.
2. Approve an ordinance rezoning the approximately 0.94-gross-acre site from the IP Industrial Park Zoning District to the LI Light Industrial Zoning District.
3. Adopt a resolution approving, subject to conditions, a Conditional Use Permit to allow the demolition of an existing approximately 1,638-square-foot building for the construction of an approximately 5,000-square-foot building to support construction equipment sale and lease use on site, and the reconfiguration of the layout of the approximately 0.94-gross-acre site.
__________________________________________________________________________
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
PROJECT DATA
GENERAL PLAN CONSISTENCY
General Plan Designation Light Industrial
Consistent Inconsistent
Consistent Policies General Plan Policies IP-1.7 and 8.2, IE-1.1, LU- 6, FS-2.3 and 4.5
SURROUNDING USES
General Plan Land
Use
Zoning Existing Use
North Residential
Neighborhood
R-1-8(PD), File No.
PDC75-058
Single-family Residential
and Railroad Track
South N/A (Public Right of
Way) & Mobile Home
Park
N/A (Public Right of
Way)
Mobile Home Park &
Public Right of Way
(ramp and landscape
areas)
East N/A (Public Right of
Way)
IP Industrial Park Railroad Track
West Mobile Home Park A(PD), File No.
PDC76-047
Mobile Home Park
PROJECT DESCRIPTION
Site Description and Surrounding Uses
As shown in the aerial map (Exhibit A), the subject 0.94-gross-acre site is located on the northwest corner of Hayes Avenue and Blossom Hill Road ramp. The site is currently developed with a small building for supporting the construction equipment sale/lease, the outdoor construction equipment storage area, parking, and circulation. The site is surrounded by a mobile home park to the west and the south, single-family residential to the north across Hayes Avenue, a railroad track to the east across Hayes Avenue, and the Blossom Hill Road ramp to the southeast.
Background
On October 30, 2023, Olivia Bergin from HMH Inc. on behalf of the applicant, Sunbelt Rentals, Inc., submitted a Conforming Rezoning application, File No. C23-115, and a Conditional Use Permit application, File No. CP24-001 for the approximately 0.94-acre site located on the northwest corner of Hayes Avenue and Blossom Hill Road ramp. The Conforming Rezoning is to rezone the site from the IP Industrial Park to the LI Light Industrial Zoning District. The Conditional Use Permit application is to allow the demolition of an existing 1,638-square-foot building and the construction of an approximately 5,000-square-foot building to support the construction equipment sale and lease use on site, and the reconfiguration of the site layout on this 0.94-gross-acre site.
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
The existing site is a construction equipment sale/lease facility. There are no Planning or Building Permit records for construction equipment sale/lease use on the subject site.
Construction equipment sale/lease is not allowed in the current IP Industrial Park Zoning District but is allowed in the LI Light Industrial Zoning District with a Conditional Use Permit. The rezoning to the LI Light Industrial Zoning District would bring the site into conformance with the General Plan Land Use/ Transportation Diagram land use designation of Light Industrial.
The Conditional Use Permit would allow the continued operation of the site as a construction equipment sale/lease facility, and the redevelopment of the site with a larger building and new site layout. The access to the site would remain from Hayes Avenue. The proposed building would be located along the western property line with a 15-foot-wide landscape buffer to the west, and the outdoor rental equipment storage/display area would be located to the east of the proposed building, closer to the roadways and train tracks. Parking would be provided to the east and south of the proposed building. An existing 6-foot-high masonry wall along the western and southern property lines separates the subject site and the mobile home park to the west and the south.
The normal business hours would be from 7:00 a.m. to 5:00 p.m. Monday to Friday and 8:00 a.m. to 4:00 p.m. on Saturdays. Customer’s pick up and drop off of construction equipment would occur during normal business hours.
ANALYSIS
The proposed project was analyzed for conformance with the following:
1. Envision San José 2040 General Plan
2. Zoning Code
3. Citywide Design Standards and Guidelines
4. Permit Findings
5. Senate Bill 330 Compliance
6. California Environmental Quality Act (CEQA)
7. Public Outreach
Envision San José 2040 General Plan Conformance
As shown in the General Plan Land Use Map (Exhibit B), the subject site has an Envision
San José 2040 General Plan l and use designation of LI Light Industrial. This designation is intended for a wide variety of industrial uses and excludes uses with unmitigated hazardous or nuisance effects. Warehousing, wholesaling, and light manufacturing are examples of typical uses in this designation. Office and higher-end industrial uses, such as research and development, are discouraged in order to preserve the scarce, lower cost land resources that are available for companies with limited operating history (startup companies) or lower cost industrial operations.
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
Analysis: The proposed LI Zoning district is a conforming zoning district to the LI land use designation. The sale/lease of construction equipment is permitted with a Conditional Use Permit in the LI Zoning District. Therefore, the proposed project is consistent with the LI General Plan land use designation.
The proposed rezoning is consistent with the following General Plan policies:
1. Implementation (Land Use/Transportation Diagram) Policy IP-1.7: Ensure proposals to rezone and pre-zone properties conform to the Land Use/Transportation Diagram, and advance Envision General Plan vision, goals, and policies.
Analysis: The LI Zoning District is a conforming district to the LI land use designation, pursuant to Section 20.120.110
of the San José Municipal Code.
2. Implementation (Zoning) Policy IP-8.2: Use the City’s conventional zoning districts, contained in its Zoning Ordinance, to implement the Envision General Plan Land Use/Transportation Diagram. These districts include a range of allowed land uses, development intensities, and standards within major land use categories (residential, commercial, and industrial) together with zoning districts for other land uses such as mixed-use and open space. The various ranges of allowed use and development intensity correspond generally to the respective Envision General Plan land use designations while providing greater detail as to the appropriate land uses and form of development.
Analysis: Any future use and development at the subject site would be required to conform with the development standards of the LI Zoning District. The allowed uses and development standards of the LI Zoning District generally correspond to the LI land use designation and would implement the Envision General Plan Land Use/Transportation Diagram.
The proposed Conditional Use Permit is consistent with the following General Plan policies:
3. Diverse and Innovative Economy Policy IE-1.1: To retain land capacity for employment uses in San José, protect and improve the quantity and quality of all lands designated exclusively for industrial uses, especially those that are vulnerable to conversion to non-employment uses.
4. Industrial Lands Goal LU-6 - Industrial Preservation: Preserve and protect industrial uses to sustain and develop the city’s economy and fiscal sustainability.
5. Fiscal Sustainability Policy FS-2.3: 3 Encourage development of industrial areas and redevelopment of existing older or marginal industrial areas (e.g. areas which could support intensified employment activity), particularly in locations that facilitate efficient commute patterns. The use of redevelopment tax increment
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
financing to provide necessary public improvements is one means of encouraging this economic development and revitalization.
6. Fiscal Sustainability Policy FS-4.5: Maintain and expand the total amount of land with either a Light Industrial or Heavy Industrial designation. Do not add overlays or other designations that would allow for non-industrial, employment uses.
Analysis for IE-1.1, LU-6, and FS-2.3 and 4.5: The project site is currently used for sale and lease of construction equipment. The proposed Conditional Use Permit would continue to allow this use with the construction of a larger building and site improvements to support this industrial business. The project would retain the industrial use on-site and generate jobs; therefore, the project would be consistent with all these policies.
Zoning Ordinance Conformance
The rezoning to the LI Light Industrial Zoning District (Exhibit D) conforms with Table 20-270 in Section 20.120.110
of the San José Zoning Code, which identifies the LI Light Industrial Zoning District as a conforming district to the General Plan Land Use/ Transportation Diagram land use designation of LI Light Industrial.
The project conforms with the LI Zoning District regulations as discussed below:
Use
The sale or lease of construction equipment requires a Conditional Use Permit pursuant to Table 20-110, Section 20.50.100
. Incidental office up to 5,000 square feet is allowed
per Section 20.50.125.A. The proposed building is to support the sale or lease of construction equipment and is 5,000 square feet. Therefore, the project complies with the requirements.
Development Standards
Setback
Per Notes 1 to 3 of Table 20-120 under Section 20.50.200, “front” refers to lot boundaries abutting streets, excluding freeways. “Side” refers to lot boundaries that do not abut streets or freeways. “Rear” refers to lot boundaries that do not abut streets or freeways. Hence, all the property lines along the public streets are the front lot lines and the two interior lot lines (western and southern lot lines) are either side or rear lot lines.
The project conforms with the following setback requirements in the LI Zoning District, except the building and parking side/rear setback requirement to the adjacent Mobile Home Park:
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
Setbacks in LI Zoning
District
Minimum
Required in feet
Proposed in feet
Front (to the street easement dedication lines)
Building 15 Minimum 60
Parking and circulation for
passenger vehicles
20 40
Interior Side/Rear (to the southern and western property lines) Building and structures
(adjacent to residential
district)
25 Building Setback:
• W estern Property Line: 15*
• Southern Property Line: 72
Structure Setback (Trash
Enclosure)
• W estern Property Line: 50
Southern Property Line: 50
Parking and circulation for
passenger vehicles/trucks
(adjacent to residential
district)
25 Western Property Line: 20*
Southern Property Line: 6.5*
*Per Zoning Code Section 20.50.240, the Director of Planning, Building and Code Enforcement may approve with a development permit, issued pursuant to Chapter
20.100, a side or rear setback of less than twenty-five feet in the LI or HI Zoning District, adjacent to a residence district, upon finding either that such a reduced setback will have no greater negative effect on the residential property than would the twenty-five- foot setback or that the reduced setback is not less than the setbacks required on the residential property.
The site is adjacent to a mobile home park to the west and the south. This mobile home park is located within a Planned Development Zoning District, File No. PDC76-047.
PDC76-047 only establishes a minimum front setback on public streets; however, there is no minimum side or rear setback requirement. The existing mobile homes to the west of the site are approximately 5 to 7.5 feet from the subject site’s western property line.
To the south of the project site is the garbage/storage area for the mobile home park.
There are no mobile homes immediately adjacent to this southern property line. The nearest mobile home is approximately 50 feet from the site’s southern property line.
The proposed 15-foot building and 20-foot parking setback to the western property line is greater than the zero side/rear setback in this Planned Development Zoning District. It is also greater than the existing 5 to 7.5-foot mobile home setback to this shared property line. In addition, the project would maintain the 6-foot-high masonry wall on this property line and a new 15-foot landscape buffer with trees along this property line to minimize the impact on the mobile homes. The noise analysis dated June 19, 2024, prepared by Illingworth & Rodkin, Inc. (Exhibit F) analyzes the noise impact and
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
concludes that with the 6-foot-high masonry wall, the predicted noise levels are expected to be below 55 dBA at the residential property line. This meets the Zoning Code performance standards requirement as discuss in the noise section below. The project would not cause a significant acoustical impact on the residences west of the site. Therefore, staff recommends granting this setback reduction.
The proposed parking setback of 6.5 feet from the southern property line is greater than the zero side/setback requirement in the PDC76-047 Zoning District. The existing 6- foot-high masonry wall would remain, and trees would be planted along this shared property line to provide a buffer between the site and the mobile home park. Given that the site immediately to the south of the project site is for garbage/storage, not for residence use, the project would not have a negative impact on the mobile home park.
Therefore, staff recommends granting this setback reduction.
Height
Pursuant to Table 20-120 under Section 20.50.200, the maximum building height is 50 feet in the LI district. The height of the proposed building is 25.5 feet. The project meets the height limit requirement.
Parking
• Vehicle Parking: The proposed use is an Other Use (OTH) and the building area is less than 30,000 square feet. Therefore, the project is exempt from the Transportation Demand Management Plan requirements per Section
20.90.900.B.2.d. The project would provide nine parking spaces. • Bicycle Parking: Bicycle parking requirement is one space per 10,000 square feet of net floor area per Table 20-190 of Section 20.90.060, or a minimum of two short-term and one long-term bicycle parking space per Section 20.90.060.A.3, whichever is greater. Therefore, a total of three bicycle parking spaces are required. The project would provide two short-term spaces and one long-term space near the building entrance. The project meets the bicycle parking space requirement.
• M otorcycle parking: Motorcycle parking shall be provided at a rate of 2.5% of the number of vehicle parking spaces provided, pursuant to Section 20.90.350. No two-wheeled motorized vehicle parking spaces are required if ten or less vehicle parking spaces are provided. With nine proposed parking spaces, the project is not required to provide motorcycle parking spaces.
Lighting
Section 20.50.250 requires light fixture heights not to exceed eight feet when adjacent to residential uses unless the setback of the fixture from the property line is twice the height of the fixture. No ground-mounted light fixture shall exceed twenty- five feet in height. All lights shall be directed downwards.
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
Residential use is to the west of the project site. The proposed 21-foot-high ground- mounted light is more than 53 feet to the western property line, more than twice the height of the lighting fixture. The 12-foot-high wall-mounted light on the north façade is setback from the western property line 25.5 feet, and the 10-foot-high wall- mounted lights on the south façade have a minimum 20 feet setback to the western property line. All the lighting fixtures are directed downwards. The photometric plan shows the proposed lighting will not result in light spillage to the adjacent mobile home park. Therefore, the project complies with Section 20.50.250.
Noise
Pursuant to Section 20.50.300, the project cannot exceed a maximum noise level of 55 dB at the property lines of the adjacent mobile home park to the west and south of the project site.
Per the noise analysis dated June 19, 2024, prepared by Illingworth & Rodkin, Inc., the predicted noise levels are expected to be below 55dBA at the residential property lines with the existing 6-foot-high masonry walls along these property lines.
The project meets this performance standard.
Citywide Design Standards and Guidelines
The project is subject to the San Jose Citywide Design Standards and Guidelines (CDSG). The CDSG includes an exception process for design standards that cannot be met and establish findings in Section 1.1.2 of the CDSG that are required to be made by decision-makers in order to grant the requested design standard exceptions. These findings include:
• There is a physical constraint or unique situation that:
o Is not created by the project applicant or property owner; and o Is not caused by financial or economic considerations. • Approving the waiver will not create a safety hazard or impair the integrity and character of the neighborhood in which the subject property is located. • The proposed project meets the intent of design standard under consideration to the extent feasible.
The project architecture, massing, materials, and site plan have been determined to be consistent with all the applicable standards, with the following two requested exceptions:
a. Section 2.3.8, S1: Select trees which at maturity create a tree canopy cover that shades a minimum of 50 percent of each on-site surface parking area, common open space at the ground floor, and POPOS (Privately Owned Public Open Spaces).
Analysis: This standard applies to the two proposed surface parking areas to the east and south of the proposed building. The proposed tree canopy coverage
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
would be approximately 18.6%. The project does not meet this standard. An exception is requested.
The project is a construction equipment sale/lease facility that requires a substantial amount of paving area for construction equipment storage/display, customer loading and delivery, parking, and truck movement. Due to the irregular shape of the site, the vehicular hardscape areas have to remain clear to accommodate vehicular turning movements and trash truck turning movements.
This limits areas for tree planting near the surface parking areas. This type of use and the lot shape are unique situations of the project that are not created by the project applicant or property owner and are not caused by financial or economic considerations. The project would still be fully landscaped with trees, plants, shrubs, and ground cover along the perimeter of the site. Approving the exception to this standard will not create a safety hazard or impair the integrity or character of the neighborhood. The proposed project also meets the intent of the design standard under consideration to the extent feasible.
All required findings can be made per the above analysis; therefore, this exception request is granted.
b. Section 2.3.8, S10: Provide a landscape buffer of at least 10 feet at the side and rear property lines and a five- to seven-foot-tall solid wall/concrete fence where Industrial General Plan land use designations abut Residential General Plan land use designations.
Analysis: The property to the west and south of the site is designated Mobile Home Park on the 2040 General Plan Land Use Map. The project includes a 6.5- foot-wide landscape buffer along the southern property line. The project does not meet this standard. An exception is requested.
This standard intends to provide sufficient buffer to the residential designated sites from industrial uses and minimize the impacts on residential use. Per the General Development Plan of PDC76-047, the area to the south of the subject site is mapped as the garbage area in the mobile home park due to its location (edge of the mobile home park), shape (triangular shape), and size (not large enough to accommodate a standard mobile home). The nearest mobile home is more than 50 feet from this shared property line. This is a unique situation of the project that is not created by the project applicant or property owner and is not caused by financial or economic considerations. The site will be fully landscaped with trees, plants, shrubs, and ground cover along the perimeter of the site.
Approving the exception to this standard will not create a safety hazard or impair the integrity or character of the neighborhood. The proposed project also meets the intent of the design standard under consideration to the extent feasible. The project would still maintain the existing 6-foot-high masonry wall on this property line, and trees will be planted within the proposed 6.5-foot landscape buffer.
All required findings can be made per the above analysis; therefore, this exception request is granted.
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
Permit Findings
Conditional Use Permit Findings
To make the Conditional Use Permit findings pursuant to San José Municipal Code Section 20.100.720, the Planning Commission must determine that:
1. The Conditional Use Permit, as approved, is consistent with and will further the policies of the general plan, applicable specific plans, and area development policies; and
Analysis: As explained in the General Plan Conformance section above, the project is consistent with the General Plan land use designation of LI Light Industrial and policies in that the project is an industrial project and continues to sustain industrial lands to develop the City’s economic base.
2. The Conditional Use Permit, as approved, conforms with the zoning code and all other provisions of the San José Municipal Code applicable to the project; and Analysis: As discussed in the San José Municipal Code Conformance section above, the project meets the height, setback, bicycle parking, and performance standards requirements in the Light Industrial Zoning District. The project is also exempt from the TDM plan requirement.
3. The Conditional Use Permit, as approved, is consistent with applicable city council policies, or counterbalancing considerations justify the inconsistency; and Analysis: Council Policy 6-30: Public Outreach Policy
was implemented to inform the
public of the project. Two on-site signs have been posted on the project frontages since January 24, 2024. A notice of the public hearing was distributed to the owners and tenants of all properties located within 500 feet of the project site and posted on the City’s website. Staff has also been available to respond to questions from the public.
4. The proposed use at the location requested will not:
a. Adversely affect the peace, health, safety, morals, or welfare of persons residing or working in the surrounding area; or
b. Impair the utility or value of property of other persons located in the vicinity of the site; or
c. Be detrimental to public health, safety, or general welfare; and Analysis: The project site is surrounded by public streets and a mobile home park to the west and the south. As discussed in the Zoning Code Conformance Section above, the site is separated from the mobile home park by a 6-foot-high perimeter wall and landscape buffers with trees along the shared property lines.
With the reconfiguration of the site operations, rental equipment will be relocated away from the western residential property line to the east side of the site, closer to the roadways to minimize impact on the mobile home residences. The equipment noise at nearby residences would be shielded by the new building and existing perimeter wall. The project would not cause a significant acoustical impact on the residences west of the site, per the noise report. In addition, the
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
site will be screened by new 6-foot-high metal fences and landscaping with a mix of grass and shrubs along street frontages. No late-night operation is allowed.
Customer’s pick-up and drop-off will occur during normal business hours.
Exterior lighting is designed to minimize glare on the neighboring properties. For the reasons above, the proposed use will not adversely affect the peace, health, safety, morals or welfare of persons residing or working in the surrounding area; or impair the utility or value of property in the vicinity of the site.
5. The proposed site is adequate in size and shape to accommodate the yards, walls, fences, loading facilities, landscaping and other development features prescribed in this title, or as is otherwise required in order to integrate said use with the uses in the surrounding area; and
Analysis: The 0.94-gross acre site is sufficient to accommodate the new 5,000- square-foot building with landscape buffers to the adjacent mobile home park, parking spaces and circulation, the outdoor equipment area, and the trash enclosure.
6. The proposed site is adequately served:
a. By highways or streets of sufficient width and improved as necessary to carry the kind and quantity of traffic such use will generate; or by other forms of transit adequate to carry the kind and quantity of individuals such use will generate; and
b. By other public or private service facilities as are required.
Analysis: The site is within a developed area that is currently served by the necessary private and public facilities. Access to the site would be from Hayes Avenue. The site is within 5 minutes of walking distance to the bus stop for Santa Clara Valley Transportation Authority (VTA) bus route 68 located at Endicott Boulevard.
7. The environmental impacts of the project, including but not limited to noise, vibration, dust, drainage, erosion, stormwater runoff, and odor which, even if insignificant for purposes of the California Environmental Quality Act (CEQA), will not have an unacceptable negative affect on adjacent property or properties.
Analysis: As stated above, the proposed development occurs in an urbanized area that is adequately serviced by all required utilities and public services, and the Stormwater Control Plan complies with the City’s stormwater policies that require low-impact development stormwater treatment measures to minimize stormwater pollutant discharges. The entire site will be fenced around with masonry walls abutting the mobile home park area and metal fences along public streets. The noise level generated by the project would not exceed the Zoning Code requirement with the existing masonry walls separating the mobile home park. A Construction Disturbance Coordinator shall be appointed to address any construction-related complaints. All construction activity will adhere to standard construction conditions, best management practices, and any regulatory agency requirements. The project would, therefore not have an unacceptable negative impact on adjacent properties.
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
Site Development Permit Findings
Chapter 20.100 of Title 20 of the San José Municipal Code establishes required findings for issuance of a Site Development Permit, which findings are made for the project based on the above-stated findings related to General Plan, Zoning and CEQA conformance and for the reasons stated below, and subject to the conditions set forth in this Permit.
1. The Site Development Permit, as approved, is consistent with and will further the policies of the General plan and applicable specific plans and area development policies.
Analysis: See Conditional Use Permit Finding No.1 above.
2. The site development permit, as approved, conforms with the zoning code and all other provisions of the San José Municipal Code applicable to the project.
Analysis: See Conditional Use Permit Finding No.2 above.
3. The site development permit, as approved, is consistent with applicable city council policies, or counterbalancing considerations justify the inconsistency.
Analysis: See Conditional Use Permit Finding No.3 above.
4. The interrelationship between the orientation, location, and elevations of proposed buildings and structures and other uses on-site are mutually compatible and aesthetically harmonious.
Analysis: The project would locate the noise-generated outdoor use in the east of the site, closer to roadways and away from mobile home residences to the west.
The building would be located along the western property line as a noise barrier to the mobile home park. The trash enclosure would be located to the south of the building and far from the public streets. In addition, the trash enclosure would be painted to match the primary building color. The building, the trash enclosure, and the outdoor construction equipment area are located in areas where they are functionally needed and are mutually compatible and aesthetically harmonious.
5. The orientation, location and elevation of the proposed buildings and structures and other uses on the site are compatible with and are aesthetically harmonious with adjacent development or the character of the neighborhood.
Analysis: The site is surrounded by mobile home park residences to the west, single-family residential to the north across Hayes Avenue, and a railroad track to the east across Hayes Avenue. All the surrounding buildings are one-story high. The proposed building is 25.5 feet high, which is compatible with the surrounding buildings. The proposed materials, such as brick veneer, can be found in nearby residential neighborhoods. The site will be enclosed by metal fences with ground cover and shrubs. The project would maintain the existing 6-foot masonry walls and
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
provide new landscape buffers with trees separating the adjacent mobile home park.
Therefore, the proposed building and its use on the site are compatible with and aesthetically harmonious with adjacent development or the character of the neighborhood.
6. The environmental impacts of the project, including but not limited to noise, vibration, dust, drainage, erosion, storm water runoff, and odor which, even if insignificant for purposes of the California Environmental Quality Act (CEQA), will not have an unacceptable negative affect on adjacent property or properties.
Analysis: See Conditional Use Permit Finding No.7 above.
7. Landscaping, irrigation systems, walls and fences, features to conceal outdoor activities, exterior heating, ventilating, plumbing, utility and trash facilities are sufficient to maintain or upgrade the appearance of the neighborhood.
Analysis: As shown on the plan sets, the landscaping, all walls and fences, utilities, and trash facilities are sufficient to maintain and upgrade the appearance of the neighborhood. The project would provide landscaping and metal fences along the streets.
8. Traffic access, pedestrian access and parking are adequate.
Analysis: The project site is accessible by a driveway along Hayes Avenue. The project would construct a standard 10- foot detached sidewalk with a minimum 4.5 - foot-wide park strip and a 5- foot-wide sidewalk along Hayes Avenue and Blossom Hill Road. A 5-foot-wide pedestrian path connects the sidewalk at Hayes Avenue and the building entrance. The project also meets the bicycle parking requirement as discussed in the Zoning Conformance section.
Evaluation Criteria for Demolition
Chapter 20.80.460 of the San José Municipal Code establishes evaluation criteria for issuance of a permit to allow for demolition. These criteria are made for the project based on the above-stated findings related to General Plan, Zoning and CEQA conformance, for the reasons stated below, and subject to the conditions set forth in this Permit.
1. The failure to approve the permit would result in the creation or continued existence of a nuisance, blight or dangerous condition;
2. The failure to approve the permit would jeopardize public health, safety or welfare;
3. The approval of the permit should facilitate a project which is compatible with the surrounding neighborhood;
4. The approval of the permit should maintain the supply of existing housing stock in the City of San Jose;
5. Both inventoried and non-inventoried buildings, sites and districts of historical significance should be preserved to the maximum extent feasible;
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
6. Rehabilitation or reuse of the existing building would not be feasible; and
7. The demolition, removal or relocation of the building without an approved replacement building should not have an adverse impact on the surrounding neighborhood.
Analysis: The existing building on-site was constructed between 1889 to 1900 and is not a building of historical significance per the review of the Department of Parks and Recreation (DPR) 523 form prepared by the historic consultant, GPA Consulting, dated April 23, 2024. The property is ineligible for listing on the National Register, California Register or City of San Jose Historic Resources Inventory. The demolition of the building would not affect the City’s housing stock since it is currently used to support construction equipment sale/lease. The demolition of the existing building would facilitate the construction of the project consistent with the General Plan and the Zoning District, as noted above, and is compatible with the surrounding uses as analyzed in the report. The demolition would not result in a nuisance, blight, or dangerous condition as the demolition would allow for the construction of the new building with the associated site improvements.
Senate Bill 330 Compliance (for Rezoning)
The Housing Crisis Act of 2019 (SB 330, 2019) limits the manner in which local governments may reduce the capacity for residential units that can be built on within the local agency’s jurisdiction, including actions such as downzoning, changing general or specific plan land use designations to a less intensive use, reductions in height, density or floor area ratio, or other types of increased requirements that work to reduce the amount of housing capacity in the jurisdiction. An exception to this limitation is that a property may be allowed to reduce the intensity of residential uses if changes in land use designations or zoning elsewhere in the jurisdiction ensure there is no net loss in residential capacity within the jurisdiction.
Analysis: The current IP Zoning District does not allow residential uses on the subject site. Therefore, the rezoning to the LI Zoning District would not reduce the capacity for residential units within the City.
CALIFORNIA ENVIRONMENTAL QUALITY ACT (CEQA)
Under the provisions of Section 15303 (c) New Construction or Conversion of Small Structures of the State Guidelines for Implementation of the California Environmental Quality Act (CEQA), the Site Development Permit is found to be exempt from the environmental review requirements of Title 21 of the San José Municipal Code, implementing the California Environmental Quality Act of 1970, as amended. CEQA Guidelines Section 15303 applies to projects that consist of small new construction, or the conversion of existing small structures from one use to another where only minor modifications are made to the exterior of the structure. CEQA Guidelines Section 15303 (c) includes the following criteria: A store, motel, office, restaurant or similar structure not involving the use of significant amounts of hazardous substances, and not
HONORABLE MAYOR AND CITY COUNCIL
February 10, 2025
Subject: C23-115, CP24-001 & ER23-250
exceeding 2500 square feet in floor area. In urbanized areas, the exemption also applies to up to four such commercial buildings not exceeding 10,000 square feet in floor area on sites zoned for such use if not involving the use of significant amounts of hazardous substances where all necessary public services and facilities are available and the surrounding area is not environmentally sensitive.
Analysis: The project site is within an urbanized area where all necessary public services and facilities are available. The project includes the demolition of an existing building that was built between 1889 to 1900. Per the review of the Department of Parks and Recreation (DPR) 523 form prepared by the historic consultant, GPA Consulting, dated April 23, 2024, this building is not a building of historical significance. The property is ineligible for listing on the National Register, California Register or City of San Jose Historic Resources Inventory. Therefore, the demolition of the building would not result in a significant cultural and resource impact. The proposed project includes one 5,000-square-foot building and will not involve the use of significant amounts of hazardous substances. The noise report concludes the project will not result in a significant noise impact on the adjacent mobile home park with the existing perimeter wall. Per the Public Works Final Memo dated October 28, 2024, the project will result in less-than-significant VMT impacts and the projected traffic for the project was found to be minimal. Therefore, CEQA Guidelines Section 15303(c) applies.
PUBLIC OUTREACH
Staff followed Council Policy 6-30: Public Outreach Policy to inform the public of the project. Two on-site signs have been posted on the project frontages since January 24, 2024. A notice of the public hearing was distributed to the owners and tenants of all properties located within 500 feet of the project site and posted on the City website. The staff report is also posted on the City’s website. Staff has been available to respond to questions from the public.
/s/
CHRISTOPHER BURTON, Director
Planning, Building and Code Enforcement
For questions, please contact John Tu, Division Manager, at (408) 535-6818.
Attachments:
Exhibit A – Aerial Map
Exhibit B – General Plan Map
Exhibit C – Existing Zoning Map
Exhibit D – Proposed Zoning Map
Exhibit E – Project Plans
Exhibit F – Noise Report
Exhibit A – Aerial Map
Exhibit B – General Plan Map
Exhibit C – Existing Zoning Map
Exhibit D – Proposed Zoning Map
PROJECT DATA
PLANNER/CIVIL ENGINEER: HMH ENGINEERS
CONTACT: OLIVIA BERGIN
1570 OAKLAND ROAD
SAN JOSE, CA 95131
(669)295- 2369
DEVELOPMENT TEAM
ARCHITECT: E2 ARCHITECTURE
CONTACT: JEFFREY EATON
1501 THE ALAMEDA, SUITE 105
SAN JOSE, CA 95126
(408)691-8998
LANDSCAPE ARCHITECT: HMH LANDSCAPE ARCHITECTURE
CONTACT: SHAWN TAYLOR
1570 OAKLAND ROAD
SAN JOSE, CA 95131
(669)295-2312
ENDICOTT BLVD/BLOSSOM HILL ROAD
SITE
ENDICOTT BLVD/BLOSSOM HILL ROAD
SITE
CONDITIONAL USE PERMIT
15 COTTLE ROAD
A DEVELOPMENT BY SUNBELT RENTALS, INC
TITLE SHEET
OB
NOT TO SCALE
OB
TABLE OF CONTENTS
PLANNING/CIVIL ENGINEERING
G1.0 TITLE SHEET
1.0 EXISTING CONDITIONS PLAN
2.0 SITE PLAN
3.0 GRADING AND DRAINAGE PLAN
4.0 UTILITY PLAN
5.0 STORMWATER CONTROL PLAN
5.1 STORMWATER CONTROL PLAN
NOTES AND DETAILS
5.2 STORMWATER CONTROL
CALCULATIONS
6.0 FIRE ACCESS PLAN
7.0 WASTE MANAGEMENT ACCESS PLAN
GOVERNMENT AGENCIES: CITY OF SAN JOSE
200 E SANTA CLARA ST
SAN JOSE, CA 95113
(408)535-3555
OWNER: SUNBELT RENTALS
CONTACT: DOUG HAYUNGS
1977 INNOVATION POINT
FORT MILL, SC 29715
(480)213-1206
PROJECT DESCRIPTION
DEVELOPER: SUNBELT RENTALS
CONTACT: DOUG HAYUNGS
1977 INNOVATION POINT
FORT MILL, SC 29715
(480)213-1206
PROPOSED PROJECT INCLUDES THE DEMOLITION OF THE EXISTING 1,638 SQUARE FEET SUNBELT RENTALS RETAIL BUILDING AND CONSTRUCTION OF A NEW 5,000 SQUARE FEET RETAIL BUILDING. RETAIL BUILDING WILL SUPPORT SUNBELT EQUIPMENT RENTALS. PROPOSED PROJECT ALSO INCLUDES 3 CUSTOMER PARKING SPACES, 6 EMPLOYEE PARKING SPACES, 1 MOTORCYCLE PARKING SPACE, AND 3 BIKE RACKS.
ARCHITECTURE
PA1 PROPOSED ARCHITECTURAL
SITE PLAN
PA2 SITE ACCESSIBILITY
PA3 PROPOSED LIGHTING PLAN
PA4 PROPOSED FLOOR PLAN
PA5 PROPOSED EAST & NORTH
EXTERIOR ELEVATIONS
PA6 PROPOSED WEST & SOUTH
EXTERIOR ELEVATIONS
PA7 SITE DETAILS
PA8 PROPOSED EXTERIOR RENDERING
LANDSCAPE
10.1 LANDSCAPE PLAN
10.2 PLANTING LEGEND, NOTES,
AND TREE MITIGATION TABLE
10.3 PLANTING DETAILS
10.4 HYDROZONE PLAN
10.5 IRRIGATION DETAILS
10.6 CONCEPT IMAGES
10.7 CONCEPT IMAGES
10.8 TREE CANOPY COVERAGE PLAN
10.9 FENCE AND GATE DETAILS
LIGHTING
P1 PHOTOMETRICS PLAN
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900TS.DWG
657900TS.DWG
G1.0
6579.00
NOV. 20, 2023
27 PLOTTED: 1/28/2025 2:06 PMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
HAYES AVENUEHAYES AVENUE
SOUTHERN PACIFIC TRANSPORTATION COMPANYSOUTHERN PACIFICTRANSPORTATION COMPANY ASSESSOR'S PARCEL NUMBER:
PROJECT ADDRESS/LOCATION:
EXISTING GENERAL PLAN DESIGNATION:
EXISTING ZONING DESIGNATION:
PROPOSED ZONING DESIGNATION:
PROPOSED USE:
GROSS SITE AREA:
RIGHT-OF-WAY DEDICATION:
NET SITE AREA:
PROPOSED SITE COVERAGE:
BUILDINGS:
PRIVATE CIRCULATION:
LANDSCAPE/HARDSCAPE:
ALLOWED HEIGHT:
690-02-003
15 COTTLE ROAD
LIGHT INDUSTRIAL (LI)
INDUSTRIAL PARK (IP)
LIGHT INDUSTRIAL
INDUSTRIAL/COMMERCIAL/RETAIL
±0.94 AC
±0.00 AC
±0.94 AC
±5,000 SF (12%)
±24,599 SF (60%)
±11,332 SF (28%)
±40,931 SF (100.0%)
MAX 50'
OB
28 Exhibit E - Project Plans
EX 6"SS
EX 8"SS
EX12"SS
EX12"SS
EX 15"SD
EX 12"SD
EX 12"SD
EX 12"SD
EX 12"SD
EX SSMH
RIM 189.0±
INV 182.17 ~6" IN (N)
INV 182.07 ~6" OUT (W)
EX 6"SS
EX SDMH
RIM 191.8±
INV 184.70~12" IN (NE)
INV 184.65~12" IN (SE)
INV 184.65~12" OUT (SW)
EX SSMH
RIM 191.8±
INV 185.00~NEW 6" IN (W)
INV 176.62~EX 12" IN (S)
INV 176.67~EX 8" IN (NW)
INV 176.57~12" OUT (NE)
EX SDMH
EX SDCI
RIM 191.3±
INV 187.31~12" OUT (SE)
EX SDJB
RIM 192.4±
INV 187.19~12" IN (NW)
INV 187.44~12" IN (NE)
INV 186.99~12 OUT (SW)
EX SDDI
RIM 191.7±
INV 188.35~12" OUT (SW)
EX 16"W
EX 12"W
HAYES AVE
ENDICOTT BLVD
SOUTHERN PACIFIC TRANSPORTATION COMPANY
Δ
Δ
EXISTING BUILDING
TO BE DEMOLISHED
±1,638 SF
EXISTING METAL
FENCE TO BE
REMOVED AND
REPLACED
EXISTING BUILDING
TO BE DEMOLISHED
±115 SF
EXISTING BUILDING
TO BE DEMOLISHED
±69 SF
EXISTING CONCRETE
TO BE DEMOLISHED
EXISTING DRIVEWAY TO
BE REMOVED/REPLACED
EXISTING
PARKING TO BE
REMOVED AND
REPLACED
EXISTING
PARKING TO BE
REMOVED AND
REPLACED
BLOSSOM HILL ROAD
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING 6'
MASONRY WALL
TO REMAIN
EXISTING
CONDITIONS PLAN
MKD
AS SHOWN
MKD
1 INCH = 20 FEET
4020 10 0
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900EX.DWG
657900EX.DWG
1.0 6579.00
NOV. 20, 2023
26 PLOTTED: 10/8/2024 12:34 PMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
1. EXISTING SURFACE FEATURES ARE PLOTTED BASED OFF THE FIELD SURVEY PERFORMED BY HMH ON OCTOBER 12,, 2023.
NOTES
LEGEND
WATER MAIN
WATER METER
WATER VALVE
ELECTROLIER
CITY STREETLIGHT CONDUIT
PROJECT BOUNDARY
CURB AND GUTTER
SANITARY SEWER
SANITARY SEWER MANHOLE
PROPERTY LINE
SIDEWALK
STORM DRAIN LINE
DRIVEWAY
SHOWN FOR INFORMATION ONLY. DESIGNED BY OTHERS
RIGHT OF WAY
FIRE HYDRANT
EXISTING
STORM DRAIN MANHOLE CSJ (SDMH)
PULL BOX
STREET SIGN
WHEELCHAIR RAMP
STORM DRAIN CURB INLET (SJDI)
STORM DRAIN FIELD INLET (SDFI)
CITY MONUMENT
FENCE
STREET SIGN
JOINT TRENCH LINE
EASEMENT LINE
ABBREVIATIONS
EX EXISTING
SPOT GRADES (AERIAL)
CONTOUR ELEVATION
141.2
RH
10/11/2024
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
NO
PARKING
VAN
ACCESSIBLE
HAYES AVE
ENDICOTT BLVD
SOUTHERN PACIFIC TRANSPORTATION COMPANY
N00°08'58"E 264.68'
S89°40'07"E 64.23'
S52°23'47"E 91.98'
L=85.77'
Δ=36°24'09"
S00°08'58"W 57.48'
L=107.02'
Δ=24°14'11"
N89°40'14"W 89.51'
EXISTING LANDS OF GBR MAGIC
SANDS MHP LLC
690-020-002
EXISTING LANDS OF SOUTHERN
PACIFIC TRANSPORTATION CO
690-020-002
PROPOSED BUILDING
±5,000 SF
15' LANDSCAPE
BUFFER
BLOSSOM HILL ROAD
CONSTRUCT NEW
ACCESSIBLE RAMP PER
CSJ STDS.
CONSTRUCT NEW 32.0' WIDE
DRIVEWAY PER CSJ STDS
NEW PUBLIC SIDEWALK TO CONFORM
WITH EXISTING SIDEWALK
CONSTRUCT NEW PUBLIC DETACHED
SIDEWALK, CURB AND GUTTER
PER CSJ STDS
15'
BUILDING
SETBACK
9'
TYP.
LOT 1
±40,931 SF
18'
TYP.
PROPOSED
EMPLOYEE
PARKING
28'
56'
PROPOSED SIDEWALK
EASEMENT
WIDTH VARIES
EXISTING LANDS OF LEE JAMES D
690-03-001
30'
36'
6'
LANDSCAPE
BUFFER
5' SIDEWALK
(P)
72'
91'
PROPOSED ADA ACCESS
(WITH MAN GATE) TO
PUBLIC RIGHT OF WAY PER
CSJ DESIGN GUIDELINES
PROPOSED TRASH
ENCLOSURE
13'
10'
6'
PED
STRIPING
PROPOSED BICYCLE
PARKING WITH
PROTECTIVE BOLLARDS
9'9'
9'
9'
9' 9'
LOCATE AND PROTECT SIGNAL INTERCONNECT
(SIC) COPPER CABLES (25 STRANDS RUNNING
ALONG ENDICOTT BLVD).
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
60'
7' WROUGHT IRON
SECURITY GATE
(TO REMAIN OPEN DURING
OPERATIONAL HOURS)
7'
WROUGHT
IRON
SECURITY
FENCE
EXISTING 6' TALL
MASONRY WALL
TO REMAIN
50'
6.5'
LANDSCAPE/SETBACK
BUFFER
2' BW
TO FENCE
1' B/W
TO FENCE
EXISTING 6' TALL
MASONRY WALL
TO REMAIN
CONSTRUCT NEW C3
BIORETENTION PLANTER
CONSTRUCT NEW C3
BIORETENTION PLANTER
SOUTHERN PACIFIC TRANSPORTATION
COMPANY
HAYES AVE
ENDICOTT BLVD
BLOSSOM HILL RD
BLOSSOMHILL RD
SITE
15.5'5'
LANDSCAPE
BUFFER
2.5'
±36'
CURB TO CURB
R/W
15.5'
SIDEWALK
PROPOSED
FENCE
SIDEWALK
ESMT
(P)
HAYES
AVENUE
TRAVEL
LANE
TRAVEL
LANE
1.5'
4'
BIOTREATMENT
5'
SIDEWALK EX.
SIDEWALK
6" CURB
TRAVEL
LANE
12.5'
3'
BIOTREATMENT
2.5'
±30'
CURB TO CURB
R/W
7.5'
EX.
SIDEWALK
PROPOSED
FENCE
SIDEWALK
ESMT
(P)
HAYES
AVENUE
TRAVEL
LANE
4.5' LANDSCAPE
5' SIDEWALK
5'
CL II
BIKE
LANE
TRAVEL
LANE
12'
3'
BIOTREATMENT
2.5'
±56'
CURB TO CURB
R/W
EX.
SIDEWALK
PROPOSED
FENCE
(P) SIDEWALK ESMT
BLOSSOM HILL
ROAD
5' SIDEWALK
TRAVEL
LANE
11'
LEFT TURN
LANE
11'12'
TRAVEL
LANE
6'
BIKE
LANE
6" CURB
SITE PLAN
OB
AS SHOWN
OB
1 INCH = 20 FEET
4020 10 0
B
C2.0
B
C2.0
SECTION 1
NTSA
VICINITY MAP
SCALE: 1" = 500'
PROJECT BOUNDARY
LEGEND
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900SP.DWG
657900SP.DWG
2.0 6579.00
NOV. 20, 2023
26 PLOTTED: 10/8/2024 12:30 PMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
PROPOSED BUILDING
EXISTING CURB AND GUTTER
PROPOSED PARKING
PROPOSED FACE OF CURB
EXISTING FENCE
BUILDING SETBACK
BIOTREATMENT AREA
PROPOSED SIDEWALK
PROPOSED FENCE
PROPOSED SIDEWALK EASEMENT
A C2.0
A C2.0
SECTION 2
NTSB
RH
CC2.0
CC2.0
SECTION 3
NTSC
10/11/2024
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
NO
PARKING
VAN
ACCESSIBLE
HAYES AVE
ENDICOTT BLVD
SOUTHERN PACIFIC TRANSPORTATION COMPANY
N00°08'58"E 264.68'
S89°40'07"E 64.23'
S52°23'47"E 91.98'
L=85.77'
Δ=36°24'09"
S00°08'58"W 57.48'
L=107.02'
Δ=24°14'11"
N89°40'14"W 89.51'
EXISTING LANDS OF GBR MAGIC
SANDS MHP LLC
690-020-002
EXISTING LANDS OF SOUTHERN
PACIFIC TRANSPORTATION CO
690-020-002
PROPOSED BUILDING
±5,000 SF
15' LANDSCAPE
BUFFER
BLOSSOM HILL ROAD
CONSTRUCT NEW
ACCESSIBLE RAMP PER
CSJ STDS.
NEW PUBLIC SIDEWALK TO CONFORM
WITH EXISTING SIDEWALK
CONSTRUCT NEW PUBLIC DETACHED
SIDEWALK, CURB AND GUTTER
PER CSJ STDS
15'
BUILDING
SETBACK
9'
TYP.
LOT 1
±40,931 SF
18'
TYP.
PROPOSED
EMPLOYEE
PARKING
28'
56'
PROPOSED SIDEWALK
EASEMENT
WIDTH VARIES
EXISTING LANDS OF LEE JAMES D
690-03-001
30'
36'
6'
LANDSCAPE
BUFFER
5' SIDEWALK
(P)
72'
91'
PROPOSED ADA ACCESS
(WITH MAN GATE) TO
PUBLIC RIGHT OF WAY PER
CSJ DESIGN GUIDELINES
PROPOSED TRASH
ENCLOSURE
13'
10'
6'
PED
STRIPING
PROPOSED BICYCLE
PARKING WITH
PROTECTIVE BOLLARDS
9'9'
9'
9'
9' 9'
LOCATE AND PROTECT SIGNAL INTERCONNECT
(SIC) COPPER CABLES (25 STRANDS RUNNING
ALONG ENDICOTT BLVD).
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
60'
6'
WROUGHT
IRON
SECURITY
FENCE
EXISTING 6' TALL
MASONRY WALL
TO REMAIN
50'
6.5'
LANDSCAPE/SETBACK
BUFFER
2' BW
TO FENCE
1' B/W
TO FENCE
EXISTING 6' TALL
MASONRY WALL
TO REMAIN
CONSTRUCT NEW C3
BIORETENTION PLANTER
CONSTRUCT NEW C3
BIORETENTION PLANTER
CONSTRUCT NEW 32.0' WIDE
DRIVEWAY PER CSJ STDS
6' WROUGHT IRON
SECURITY GATE
(TO REMAIN OPEN DURING
OPERATIONAL HOURS)
SOUTHERN PACIFIC TRANSPORTATION
COMPANY
HAYES AVE
ENDICOTT BLVD
BLOSSOM HILL RD
BLOSSOMHILL RD
SITE
15.5'5'
LANDSCAPE
BUFFER
2.5'
±36'
CURB TO CURB
R/W
15.5'
SIDEWALK
PROPOSED
FENCE
SIDEWALK
ESMT
(P)
HAYES
AVENUE
TRAVEL
LANE
TRAVEL
LANE
1.5'
4'
BIOTREATMENT
5'
SIDEWALK EX.
SIDEWALK
6" CURB
TRAVEL
LANE
12.5'
3'
BIOTREATMENT
2.5'
±30'
CURB TO CURB
R/W
7.5'
EX.
SIDEWALK
PROPOSED
FENCE
SIDEWALK
ESMT
(P)
HAYES
AVENUE
TRAVEL
LANE
4.5' LANDSCAPE
5' SIDEWALK
5'
CL II
BIKE
LANE
TRAVEL
LANE
12'
3'
BIOTREATMENT
2.5'
±56'
CURB TO CURB
R/W
EX.
SIDEWALK
PROPOSED
FENCE
(P) SIDEWALK ESMT
BLOSSOM HILL
ROAD
5' SIDEWALK
TRAVEL
LANE
11'
LEFT TURN
LANE
11'12'
TRAVEL
LANE
6'
BIKE
LANE
6" CURB
SITE PLAN
OB
AS SHOWN
OB
1 INCH = 20 FEET
4020 10 0
B
C2.0
B
C2.0
SECTION 1
NTSA
VICINITY MAP
SCALE: 1" = 500'
PROJECT BOUNDARY
LEGEND
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900SP.DWG
657900SP.DWG
2.0 6579.00
NOV. 20, 2023
28 PLOTTED: 2/4/2025 4:38 PMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
PROPOSED BUILDING
EXISTING CURB AND GUTTER
PROPOSED PARKING
PROPOSED FACE OF CURB
EXISTING FENCE
BUILDING SETBACK
BIOTREATMENT AREA
PROPOSED SIDEWALK
PROPOSED FENCE
PROPOSED SIDEWALK EASEMENT
A C2.0
A C2.0
SECTION 2
NTSB
RH
CC2.0
CC2.0
SECTION 3
NTSC
Exhibit E - Project Plans
NO
PARKING
VAN
ACCESSIBLE
EXISTING LANDS OF GBR MAGIC
SANDS MHP LLC
690-020-002
IC
EX TC 190.1±
EX TC 191.5±
EX FS 191.5±
3.0%
TC 190.7
TC 191.0
TC 191.4
TC 192.2 HP
TC 193.3
TC 193.0
TC 191.4
TC 192.6 HP
TC 192.0
FS 191.5
1.8%
TC 192.2
FS 191.7
TC 192.4 HP
TC 192.1
TC 192.1 LP
TC 192.0 HP
TC 191.8 LP
TC 191.8
0.5%
0.5%
0.9%
TC 191.5
TC 191.5 LP
TC 194.1
TC 193.7
TC 193.5
TC 193.7
EX FS 190.2±
FS 190.7
FF 193.7
TC 192.0
3.4%
3.9%
FS 193.7~GB
2.8%
1.5%
TC 191.9 LP
1.7%
TC 192.2
4.7%
0.5%
0.5%
0.7%
1.3%
0.6%
0.6%
0.5%
0.5%
TC 192.0
TC 191.7
0.5%
3.6%
1.7%
1.8%
TC 191.5
4.0%
1.3%
TC 191.3 LP
BG 190.6
EG 190.9±
EG 191.3±
EG 191.3±
EG 191.1±
EG 191.5±
EG 191.4±
EG 190.5± EG 189.5±
TC 190.4±
BG 190.7
BG 190.3
BG 189.8
BG 190.8
1.8%
1.8%
1.8%
9.5%
7:1
6:1
RIDGE
RIDGE
RIDGE
RIDGE
TC 189.9±
TC 189.2±
2.2%
7:1
HAYES AVENUE
ENDICOTT BLVD.
BLOSSOM HILL ROAD
15 COTTLE
(PROJECT SITE)
0.5%
0.5%
FF 193.7
BG 188.4
1.0%
FS 193.3
FF 193.7
FS 193.6
TC 193.6
TC 193.5
4.8%
1.7%
FS 190.8
1.4%
1.5%
2.2%
FF 193.7
3.6%
2.4%
1.4%
TC 190.6~GB
0.6%
1.0%
FS 193.2
5.0%
GB
GB
GB
GB
GB
TC 193.59~GB
FS 193.6~GB
FS 192.9~GB
FS 192.9~GB
FS 192.9~GB
FF 193.7
FS 193.4
FS 193.4
FS 193.4~GB
FS 193.4
FS 193.4~GB
1.9%
6.8%
FS 193.6~GB
GB
1.8%
RIDGE
1.5% (EX.)
GRADING AND
DRAINAGE PLAN
MKD/AV
AS SHOWN
MKD/AV
1 INCH = 20 FEET
4020100
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900GP.DWG
657900GP.DWG
3.0 6579.00
NOV. 20, 2023
26 PLOTTED: 10/8/2024 12:32 PMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
ABBREVIATIONS
L
LC / CL CENTERLINE
CMU CONCRETE MASONRY UNIT
EG EXISTING GROUND
EX EXISTING
FF FINISHED FLOOR
FG FINISHED GRADE
FS FINISHED SURFACE
GB GRADE BREAK
HP HIGH POINT
LP LOW POINT
NTS NOT TO SCALE
P / PL PROPERTY LINE
RW RIGHT OF WAY
DS RAIN WATER LEADER
TC TOP OF CURB
LEGEND PROPOSED EXISTING
DIRECTION OF SURFACE DRAINAGE
PROPERTY LINE
OVERLAND RELEASE PATH
RETAINING WALL (CMU)
BOUNDARY
CURB AND GUTTER
SIDEWALK
DRIVEWAY
DETAIL CALLOUT DETAIL
SHEET NUMBER
A
3 CURB CUT W/ 6" TAPER -
SEE DETAIL 4/C5.1
RH
BIORETENTION AREA
SEE SHEET C5.0
10/11/2024
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
EX 8"SS
EX12"SS
EX12"SS
EX 15"SD
EX 12"SD
EX 12"SD
EX 12"SD
EX 12"SD
INV 182.17 ~6" IN (N)
INV 182.07 ~6" OUT (W)
EX SDMH
RIM 191.8±
INV 184.70~12" IN (NE)
INV 184.65~12" IN (SE)
INV 184.65~12" OUT (SW)
EX SSMH
RIM 191.8±
INV 185.00~NEW 6" IN (W)
INV 176.62~EX 12" IN (S)
INV 176.67~EX 8" IN (NW)
INV 176.57~12" OUT (NE)
EX SDCI
RIM 191.3±
INV 187.31~12" OUT (SE)
EX SDJB
RIM 192.4±
INV 187.19~12" IN (NW)
INV 187.44~12" IN (NE)
INV 186.99~12 OUT (SW)
EX SDDI
RIM 191.7±
INV 188.35~12" OUT (SW)
EX 16"W
EX 12"W
NO
PARKING
VAN
ACCESSIBLE
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
W
W
W
2"W
SS
SS
SS
SS
F
FF
6"FW
6"SS
4"SS
4"SS
SS
SS
SS
6"SD
6"SD
6"SS
F
F
6"FW
F F
SD
SD
SD
SD
SD
SD
SD
6"SD
6"SD
12"SD
12"SD
12"SD
6"FW
6"SD
4"SS
IRR
SD
12"SD
6"SD
6"FW
SSMH
RIM 191.62
INV 186.96 ~6" THRU
SDCO
INV 189.00
106' ~ 6" SS (PVC) @ S=0.0242
SDDI
TG 190.30
INV 186.80 ~ 6" OUT (NW)
SDDI
TG 190.80
INV 187.30 ~ 6" OUT
SD BUBBLER
TG 190.90
INV 188.6 ~ 6" IN (N)
SDCO
INV 191.34
SD BUBBLER
TG 191.60
INV 189.96 ~ 6" IN (S)
SDDI
TG 191.10
INV 187.60 ~ 6" OUT (NE)
SDMH
RIM 190.3±
INV 182.12~12" IN (SE)
INV 179.2±~EX 15" OUT (W)
SDDI
TG 191.20
INV 187.70 ~ 6" OUT
4" SS STUB
INV 190.70
22'~4" SS (PVC)
42'~4" SS (PVC)
@S=0.0242
SSCO
INV 190.54
SSCO
INV 189.52
SDMH
RIM 191.2
INV 186.64~6" IN (SE)
INV 186.07~6" IN (W)
INV 185.59~6" OUT (NE)
98' ~ 6" SS @ S=0.02
SDMH
RIM 190.7
INV 182.62~12" IN (SE)
INV 187.36~6" IN (S)
INV 186.16~6" IN (E)
INV 182.62~12" OUT (NW
123' ~ 6" SD (PVC) @ S=0.01
24'~6" SD (PVC)
@S=0.01
4" SS STUB
INV 190.70
OWS
S=0.0079
16'~6" SD (PVC)
@S=0.01
25'~12" SD
@S=0.02
19'~6" SD
(PVC)
69'~6" SD (PVC)
@ S=0.02
HAYES AVENUE
HAYES AVENUE
ENDICOTT BLVD.
BLOSSOM HILL ROAD
SDDI
TG 191.00
INV 187.80 ~ 6" OUT (W)
16'~6" SD (PVC)
@S=0.01
87' ~ 6" SD (PVC) @ S=0.01
SDMH
RIM 191.4
INV 184.72~6" IN (SW)
INV 187.64~6" IN (E)
INV 184.62~12" OUT (NW)
200' ~ 12" SD (PVC) @ S=0.01
54'~6" SD (PVC)
@ S=0.02
SSAD
RIM 192.90
INV 190.90
15'~4" SS (PVC)
@S=0.0242
SDDI
RIM 188.9
INV 184.90 ~ 12" OUT (SE)
SDMH
RIM 190.0±
INV 184.14 ~ 12" IN (NW)
INV 184.00 ~ 12" THRU
38'~12" SD (PVC)
@S=0.02
SDDI
TG 189.82
INV 186.32 ~ 6" OUT (W)
16'~6" SD (PVC)
@S=0.01
SDCO
INV 189.68
CONNECT
DOWNSPOUT TO
SDCO
28.3'
28.9'
CONNECT
DOWNSPOUT TO
SDCO
UTILITY PLAN
MKD
AS SHOWN
MKD
1 INCH = 20 FEET
4020 10 0
PROJECT BOUNDARY
LEGEND
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900UT.DWG
657900UT.DWG
4.0 6579.00
NOV. 20, 2023
26 PLOTTED: 10/8/2024 11:59 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
LEGEND
WATER SERVICE AND METER
WATER VALVE
BUBBLER
CONDUIT
PROJECT BOUNDARY
CURB AND GUTTER
STREET MONUMENT
EASEMENT
SANITARY SEWER
SANITARY SEWER MANHOLE CSJ D-11
CENTERLINE
PROPERTY LINE
SIDEWALK
STORM DRAIN LINE
RIGHT OF WAY
FIRE HYDRANTS
TREE
PROPOSED EXISTING
STORM DRAIN MANHOLE CSJ D-11
PULL BOX
STREET SIGN
SANITARY LATERAL
SANITARY SEWER CLEAN OUT
STORM DRAIN CURB INLET
JOINT TRENCH
GAS
SS
SD
STORM DRAIN FIELD INLET (1X1)
STORM DRAIN FIELD INLET (2X2)
W
BACK FLOW VALVE
FIRE SERVICE CONNECTION
UTILITY POLE
CONCRETE VALLEY GUTTER
EP
WATER MAIN
RH
STORM DRAIN DOWNSPOUT
STORM DRAIN PLUG
STORM DRAIN PERFORATED PIPE
10/11/2024
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
SD
SD
SD
SD
SD
SD
SD
SD
SD
SD
6"SD
6"SD
SD
SD
SD
SD
SD
SD
SD
6"SD
6"SD
12"SD
12"SD
12"SD
6"SD
SD
12"SD
6"SD
EX 15"SD
EX 12"SD
EX 12"SD
EX 12"SD
EX 12"SD
EX SDMH
RIM 191.8±
INV 184.70~12" IN (NE)
INV 184.65~12" IN (SE)
INV 184.65~12" OUT (SW)
EX SDMH
RIM 188.9±
INV 183.07~12" IN (NE)
INV 182.92~6" IN (N)
INV 182.87~18" OUT (SW)
EX SDCI
RIM 191.3±
INV 187.31~12" OUT (SE)
EX SDJB
RIM 192.4±
INV 187.19~12" IN (NW)
INV 187.44~12" IN (NE)
INV 186.99~12 OUT (SW)
EX SDDI
RIM 191.7±
INV 188.35~12" OUT (SW)
NO
PARKING
VAN
ACCESSIBLE
TCM 1
(347 sf)
TCM 2
(126 sf)
TCM 3
(200 sf)
TCM 4
(217 sf)
TCM 5
(347 sf)
DMA 1
DMA 2
DMA 3
DMA 4
DMA 5
DMA 6
DMA 7
TCM 6
(302 sf)
TCM 7
(175 sf)
ROOF
DOWNSPOUT
CONNECTION
ROOF
DOWNSPOUT
CONNECTION
HAYES AVENUE
ENDICOTT BLVD.
BLOSSOM HILL ROAD
ROOF
DOWNSPOUT
CONNECTION
CITY OF SAN JOSE MAINTAINED
STORMWATER TREATMENT OPERATION
AND MAINTENANCE INFORMATION:
I. RESPONSIBLE PARTY FOR MAINTENANCE:
I.A. CONTACT:
CITY OF SAN JOSE
DEPARTMENT OF TRANSPORTATION
I.B. PHONE NUMBER OF CONTACT:
(408) 794-1900
I.C. EMAIL: [email protected]
I.D. ADDRESS:
1404 MABURY ROAD
SAN JOSE, CA 95133
STORMWATER
CONTROL PLAN
MKD
AS SHOWN
MKD
1 INCH = 20 FEET
4020 10 0
DMA#
LID TREATMENT DRAINAGE AREA
(SEE SIZING CALCULATIONS,
SHEET C5.1)
STORM DRAIN PIPE (EXISTING)
STORM DRAIN PIPE SD SD SD
CATCH BASIN
STORM DRAIN MANHOLE
CATCH BASIN (EXISTING)
CURB INLET (EXISTING)
STORM DRAIN MANHOLE (EXISTING)
PROJECT BOUNDARY
LEGEND
BIORETENTION AREA
FLOW DRAINAGE
CURB CUT W/ 6" TAPER - SEE DETAIL 2/C5.1
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900SW.DWG
657900SW.DWG
5.0 6579.00
NOV. 20, 2023
26 PLOTTED: 10/8/2024 12:26 PMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
PROJECT SITE INFORMATION:
1. SOILS TYPE: CLAY LOAM
2. GROUND WATER DEPTH: 20-30 FEET
3. NAME OF RECEIVING BODY: CANOAS CREEK
4. FLOOD ZONE: ZONE D
5. FLOOD ELEVATION (IF APPLICABLE): N/A
OPERATION AND MAINTENANCE
INFORMATION:
I. PROPERTY INFORMATION:
I.A. PROPERTY ADDRESS:
APN 690-02 -003
I.B. PROPERTY OWNER:
SUNBELT RENTALS
II. RESPONSIBLE PARTY FOR MAINTENANCE:
II.A. CONTACT:
DOUGLAS HAYUNGS
II.B. PHONE NUMBER OF CONTACT:
(480)-213-1206
II.C. EMAIL:
[email protected]
II.D. ADDRESS:
1799 Innovation Point
Fort Mill, SC 29715
RH
10/11/2024
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
12" MIN. OF CLASS II PERMEABLE ROCK
PER CALTRANS SPECS. ROCK SECTION
TO INCREASE IF PERFORATED PIPE
REACHES BOTTOM OF 12" SECTION.
BIO-TREATMENT
SOIL MIX (BSM)
PER SPECS.
VARIES VARIES
PERFORATED PIPE
(SLOPE AT 0.50% MIN)
W/ PERFORATIONS DOWN.
SEE PLAN FOR LENGTH
AND LOCATION.
CHRISTY V12
OR APPROVED EQUAL
OVERFLOW RISER
W/ GRATE
3:1 MAX
18"
CLEANOUT
W/ CAP AT
FINISH GRADE
6"
VARIES-SEE PLAN
VARIES-SEE PLAN
PLACE 4" MIN. DIA. APPROVED COBBLE 0.2'
BELOW CURB OPENINGS FOR DISTANCE
OF 2' EITHER SIDE OF CURB OPENINGS.
PLACE GEOTEXTILE BETWEEN COBBLES &
NATIVE SOIL FOR EROSION CONTROL.
SOLID OVERFLOW PIPE
CURB OPENING
(SEE DETAIL AND
PLAN FOR LOCATION)
BIORETENTION BASIN W/O LINER
SIZING METHOD:
4%
1 N.T.S.
2"
MIN.4"
RISER HEIGHT SEE TCM
SUMMARY TABLE
0.2"
PAVEMENT
SLOPE TO
DRAIN
18" MIN. 6" HIGH
CURB
6" HIGH
CURB
SECTION VIEW
1 6"
A
A
A-A
SEE
BIORETENTION
OR
FTP DETAILS
CURB OPENING4 N.T.S.
WARPED
GUTTER
CL
PLAN VIEW
3'-6" 12"
A
A
1'-6" MIN 6"
VARIES
SEE
PLAN
0.2'
MIN.6"
6"X"
3 MAX
PLACE 4" MIN. DIA. APPROVED
COBBLE 0.2' BELOW CURB
OPENINGS FOR DISTANCE OF 2'
EITHER SIDE OF CURB OPENINGS
DEPRESS 2"
AT OPENING
24" 24"
FLOWS TO
BIORETENTION AREA
SOURCE CONTROL MEASURES:
1. CONNECT THE FOLLOWING FEATURES TO SANITARY SEWER:
a. COVERED TRASH/ RECYCLING ENCLOSURES.
b. WASH AREA/ RACKS.
2. BENEFICIAL LANDSCAPING.
3. USE OF WATER EFFICIENT IRRIGATION SYSTEMS.
4. MAINTENANCE (PAVEMENT SWEEPING, CATCH BASIN CLEANING, GOOD HOUSEKEEPING).
5. STORM DRAIN LABELING.
SITE DESIGN MEASURES:
1. PROTECT EXISTING TREES, VEGETATION, AND SOIL.
2. CREATE NEW PERVIOUS AREAS:
a. LANDSCAPING
3. DIRECT RUNOFF FROM ROOFS, SIDEWALKS, PATIOS TO
LANDSCAPED AREAS.
4. REDUCE EXISTING IMPERVIOUS SURFACES
5. PLANT TREES ADJACENT TO AND IN PARKING AREAS AND
ADJACENT TO OTHER IMPERVIOUS AREAS.
6. PARKING:
a. NOT PROVIDED IN EXCESS OF CODE.
0.1 FT
12"
12"
3 MAX
1 24"
WATER STOP. SEE
CITY OF SAN JOSE
DETAIL D-19
3/4"
CRUSHED
DRAIN ROCK
VARIES SEE
TCM
SUMMARY
TABLE
BUBBLER BOX DETAIL3 N.T.S.N.T.S.
V 12 CHRISTY BOX
WITH OPEN GRATE
SEE PLAN FOR
RIM ELEVATION
INSTALL 24" WIDE APRON
OF 4" COBBLES AROUND
BUBBLER RIM
OVERFLOW
RISER
W/GRATE
IMPERMEABLE LINER
ALONG VERTICAL EDGE PLACE GEOTEXTILE
BETWEEN COBBLES &
NATIVE SOIL FOR
EROSION CONTROL
CONTRACTOR TO DRILL
2 ROWS OF (2)
2" DIA. WEEPHOLES
DRAIN ROCK TO BE LINED
WITH 20-MIL HDPE WATER
BARRIER ALONG VERTICAL
EDGE WITH A 2" WRAP
OPEN TO DRAIN
BIORETENTION POND
0.2'
VARIES PER
DESIGN
X** IF TOP OF WALL TO BOTTOM
OF FOOTING IS GREATER
THAN OR EQUAL TO 4' WALL
SHALL BE STRUCTURALLY
DESIGNED AND APPROVED
BY PUBLIC WORKS PRIOR TO
CONSTRUCTION.
SEE
BIORETENTION
OR
FTP DETAILS
5 N.T.S.CURB ADJACENT TO BIORETENTION
BOTTOM OF
BIORETENTION
BASIN
SET BOTTOM OF CURB PER
GEOTECHNICAL REPORT TO
FOR PAVEMENT STABILITY AND
TO AVOID WATER INFILTRATION
UNDER PAVEMENT
INSTALL 4" MIN DIA. APPROVED
COBBLE 0.2 FEET BELOW CURB
OPENINGS FOR DISTANCE OF 2'
EITHER SIDE OF CURB OPENINGS.
SEE PLAN VIEW FOR LOCATION
CURB & GUTTER
3:1
MAX
SIDE SLOPE1
3 MAX.
SLOPE VARIES
REV. DATE SEPTEMBER 2021
BIORETENTION BASIN W/O LINER2
SIZING METHOD:
FLOW-COMBO
N.T.S.
PERFORATED PIPE (SLOPE AT
0.50% MIN) W/ PERFORATIONS
DOWN. SEE PLAN FOR LENGTH
AND LOCATION.
SOLID OVERFLOW PIPE
NATIVE MATERIAL
PLACE GEOTEXTILE BETWEEN COBBLES &
NATIVE SOIL FOR EROSION CONTROL
CURB OPENING
(SEE DETAIL AND
PLAN FOR LOCATION)
PLACE 4" MIN. DIA. APPROVED COBBLE 0.2'
BELOW CURB OPENINGS FOR DISTANCE
OF 2' EITHER SIDE OF CURB OPENINGS
CHRISTY V12
OR APPROVED
EQUAL OVERFLOW
RISER W/ GRATE
CLEANOUT
W/ CAP AT
FINISH GRADE
RISER HEIGHT
SEE TCM
TABLE
12" MIN. OF CLASS II PERMEABLE
ROCK PER CALTRANS SPECS.
ROCK SECTION TO INCREASE IF
PERFORATED PIPE REACHES
BOTTOM OF 12" SECTION
IF NATIVE MATERIAL IS USED FOR
SIDESLOPE, RELATIVE COMPACTION OF
SUBGRADE TO BE SIMILAR TO ADJOINING
NATIVE SOILS
BIO-TREATMENT
SOIL MIX (BSM)
PER SPECS.
18"
(BSM)
12"
MIN.
SEE PLAN
6"
2"
MIN.4"
0.2'
1. SEE GRADING PLAN FOR BASIN FOOTPRINT AND DESIGN
ELEVATIONS.
2. PLACE 3 INCHES OF COMPOSTED, NON-FLOATABLE MULCH IN
AREAS BETWEEN STORMWATER PLANTINGS.
3. SEE LANDSCAPE PLAN FOR MULCH, PLANT MATERIALS AND
IRRIGATION REQUIREMENTS
4. CURB CUTS SHALL BE A MINIMUM 18" WIDE AND SPACED AT
MAXIMUM 10' O.C. INTERVALS AND SLOPED TO DIRECT
STORMWATER TO DRAIN INTO THE BASIN. CURB CUTS SHALL
ALSO NOT BE PLACED INLINE WITH OVERFLOW CATCH BASIN.
SEE GRADING PLAN FOR MORE DETAIL ON LOCATIONS OF CURB
CUTS.
5. A MINIMUM 0.2' DROP BETWEEN STORM WATER ENTRY POINT
(I.E. CURB OPENING, FLUSH CURB, ETC.) AND ADJACENT
LANDSCAPE FINISHED GRADE.
6. DO NOT COMPACT NATIVE SOIL / SUBGRADE AT BOTTOM OF
BASIN. LOOSEN SOIL TO 12" DEPTH.
BIORETENTION & FLOW-THROUGH PLANTER NOTES:BIOTREATMENT SOIL REQUIREMENTS · BIORETENTION SOIL MIX SHALL MEET THE
REQUIREMENTS AS OUTLINED IN APPENDIX C OF THE C.3
STORM WATER HANDBOOK AND SHALL BE A MIXTURE OF
FINE SAND AND COMPOST MEASURED ON A VOLUME
BASIS OF 60-70% SAND AND 30-40% COMPOST.
CONTRACTOR TO REFER TO APPENDIX C FOR SAND AND
COMPOST MATERIAL SPECIFICATIONS. CONTRACTOR
MAY OBTAIN A COPY OF THE C3 HANDBOOK AT :
HTTPS://CLEANWATER.SCCGOV.ORG/SITES/G/FILES/
EXJCPB461/FILES/SCVURPP_C.PDF
· PRIOR TO ORDERING THE BIOTREATMENT SOIL MIX OR
DELIVERY TO THE PROJECT SITE, CONTRACTOR SHALL
PROVIDE A BIOTREATMENT SOIL MIX SPECIFICATION
CHECKLIST, COMPLETED BY THE SOIL MIX SUPPLIER AND
CERTIFIED TESTING LAB.
TO
STORM
DRAIN
FLOW-THROUGH PLANTER (BELOW GRADE)6
SIZING METHOD:
4%
N.T.S.
* IF TOP OF WALL TO BOTTOM
OF FOOTING IS GREATER
THAN OR EQUAL TO 4' WALL
SHALL BE STRUCTURALLY
DESIGNED AND APPROVED
BY PUBLIC WORKS PRIOR TO
CONSTRUCTION.
DOWNSPOUT NOTE:
IN THE EVENT ONLY ONE
DOWNSPOUT IS LOCATED
WITHIN THE FLOW-THROUGH
PLANTER BOX, CONTRACTOR
SHALL INSTALL A FLOW
SPREADER AT THE
DOWNSPOUT TO ENSURE
PROPER DISTRIBUTION OF
STORMWATER OVER THE
ENTIRE PLANTER.
REINF. CONCRETE
PLANTER
PERFORATED PIPE (SLOPE AT 0.50% MIN)
W/ PERFORATIONS DOWN. SEE PLAN FOR
LENGTH AND LOCATION.
12" MIN. OF CLASS II PERMEABLE ROCKPER
CALTRANS SPECS. ROCK SECTION TO
INCREASE WITH SLOPE OF PIPE.
4" MIN. DIA. APPROVED
COBBLE 0.2' BELOW
DOWNSPOUTS FOR
DISTANCE OF 2' EITHER
SIDE OF DOWNSPOUT
CLEANOUT
W/ CAP AT
FINISH GRADE
PLACE 4" MIN. DIA. APPROVED COBBLE 0.2'
BELOW CURB OPENINGS FOR DISTANCE
OF 2' EITHER SIDE OF CURB OPENINGS
CURB OPENING
(SEE DETAIL AND
PLAN FOR LOCATION)
BIO-TREATMENT
SOIL MIX (BSM)
PER SPECS.
WATERPROOF MEMBRANE PER
STRUCTURAL PLANS.
X* 0.2'
18"
(BSM)12"
MIN.
RISER
HEIGHT
SEE TCM
TABLE
NOTE:
3" OF NON FLOATABLE MULCH
IS REQUIRED FOR THIS FLOW
THOUGH PLANTER
CURB OPENING
(SEE DETAIL AND
PLAN FOR LOCATION)
STORMWATER
CONTROL PLAN
NOTES & DETAILS
MKD
NOT TO SCALE
MKD
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900SW.DWG
657900SW.DWG
5.1 6579.00
NOV. 20, 2023
26 PLOTTED: 10/8/2024 12:27 PMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
RH
10/11/2024
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
TABLE 1
ROUTINE MAINTENANCE ACTIVITIES FOR BIORETENTION AREAS
NO. MAINTENANCE TASK FREQUENCY OF TASK
1 REMOVE OBSTRUCTIONS, WEEDS, DEBRIS AND TRASH FROM BIORETENTION AREA AND ITS INLETS AND OUTLETS; AND DISPOSE OF PROPERLY.
QUARTERLY, OR AS NEEDED
AFTER STORM EVENTS
2 INSPECT BIORETENTION AREA FOR STANDING WATER. IF STANDING WATER DOES NOT DRAIN WITHIN 2-3 DAYS, TILL AND REPLACE THE SURFACE BIOTREATMENT SOIL WITH THE APPROVED SOIL MIX AND REPLANT.
QUARTERLY, OR AS NEEDED
AFTER STORM EVENTS
3 CHECK UNDERDRAINS FOR CLOGGING. USE THE CLEANOUT RISER TO CLEAN ANY CLOGGED UNDERDRAINS.
QUARTERLY, OR AS NEEDED
AFTER STORM EVENTS
4 MAINTAIN THE IRRIGATION SYSTEM AND ENSURE THAT PLANTS ARE RECEIVING THE CORRECT AMOUNT OF WATER (IF APPLICABLE). QUARTERLY
5 ENSURE THAT THE VEGETATION IS HEALTHY AND DENSE ENOUGH TO PROVIDE FILTERING AND PROTECT SOILS FROM EROSION. PRUNE AND WEED THE BIORETENTION AREA. REMOVE AND/OR REPLACE ANY DEAD PLANTS.
ANNUALLY, BEFORE THE WET
SEASON BEGINS
6 USE COMPOST AND OTHER NATURAL SOIL AMENDMENTS AND FERTILIZERS
INSTEAD OF SYNTHETIC FERTILIZERS, ESPECIALLY IF THE SYSTEM USES AN UNDERDRAIN.
ANNUALLY, BEFORE THE WET
SEASON BEGINS
7 CHECK THAT MULCH IS AT APPROPRIATE DEPTH (2 - 3 INCHES PER SOIL SPECIFICATIONS) AND REPLENISH AS NECESSARY BEFORE WET SEASON BEGINS.
IT IS RECOMMENDED THAT 2” – 3” OF ARBOR MULCH BE REAPPLIED EVERY YEAR.
ANNUALLY, BEFORE THE WET
SEASON BEGINS
8 INSPECT THE ENERGY DISSIPATION AT THE INLET TO ENSURE IT IS FUNCTIONING ADEQUATELY, AND THAT THERE IS NO SCOUR OF THE SURFACE MULCH. REMOVE ACCUMULATED SEDIMENT.
ANNUALLY, BEFORE THE WET
SEASON BEGINS
9 INSPECT OVERFLOW PIPE TO ENSURE THAT IT CAN SAFELY CONVEY EXCESS FLOWS TO A STORM DRAIN. REPAIR OR REPLACE DAMAGED PIPING.
ANNUALLY, BEFORE THE WET
SEASON BEGINS
10 REPLACE BIOTREATMENT SOIL AND MULCH, IF NEEDED. CHECK FOR STANDING WATER, STRUCTURAL FAILURE AND CLOGGED OVERFLOWS. REMOVE TRASH AND DEBRIS. REPLACE DEAD PLANTS.
ANNUALLY AT THE END OF THE RAINY SEASON, AND/OR AFTER LARGE STORM EVENTS 11 INSPECT BIORETENTION AREA USING THE ATTACHED INSPECTION CHECKLIST. ANNUALLY, BEFORE THE WET SEASON
TABLE 1
ROUTINE MAINTENANCE ACTIVITIES FOR FLOW-THROUGH PLANTERS NO. MAINTENANCE TASK FREQUENCY OF TASK
1 INSPECT THE PLANTER SURFACE AREA, INLETS AND OUTLETS FOR OBSTRUCTIONS AND TRASH; CLEAR ANY OBSTRUCTIONS AND REMOVE TRASH. QUARTERLY 2 INSPECT PLANTER FOR STANDING WATER. IF STANDING WATER DOES NOT DRAIN WITHIN 2-3 DAYS, THE SURFACE BIOTREATMENT SOIL SHOULD BE TILLED OR REPLACED WITH THE APPROVED SOIL MIX AND REPLANTED. USE THE CLEANOUT RISER TO CLEAR ANY UNDERDRAINS OF OBSTRUCTIONS OR CLOGGING MATERIAL.
QUARTERLY
3 CHECK FOR ERODED OR SETTLED BIOTREATMENT SOIL MEDIA. LEVEL SOIL WITH RAKE AND REMOVE/REPLANT VEGETATION AS NECESSARY. QUARTERLY 4 MAINTAIN THE VEGETATION AND IRRIGATION SYSTEM. PRUNE AND WEED TO KEEP FLOW-THROUGH PLANTER NEAT AND ORDERLY IN APPEARANCE. QUARTERLY 5 EVALUATE HEALTH AND DENSITY OF VEGETATION. REMOVE AND REPLACE ALL DEAD AND DISEASED VEGETATION. REMOVE EXCESSIVE GROWTH OF PLANTS THAT ARE TOO CLOSE TOGETHER.
ANNUALLY, BEFORE THE RAINY
SEASON BEGINS
6 USE COMPOST AND OTHER NATURAL SOIL AMENDMENTS AND FERTILIZERS
INSTEAD OF SYNTHETIC FERTILIZERS, ESPECIALLY IF THE SYSTEM USES AN UNDERDRAIN.
ANNUALLY, BEFORE THE RAINY
SEASON BEGINS
7 INSPECT THE OVERFLOW PIPE TO MAKE SURE THAT IT CAN SAFELY CONVEY EXCESS FLOWS TO A STORM DRAIN. REPAIR OR REPLACE ANY DAMAGED OR DISCONNECTED PIPING. USE THE CLEANOUT RISER TO CLEAR UNDERDRAINS OF OBSTRUCTIONS OR CLOGGING MATERIAL.
ANNUALLY, BEFORE THE RAINY
SEASON BEGINS
8 INSPECT THE ENERGY DISSIPATOR AT THE INLET TO ENSURE IT IS FUNCTIONING ADEQUATELY, AND THAT THERE IS NO SCOUR OF THE SURFACE MULCH. REMOVE ANY ACCUMULATION OF SEDIMENT.
ANNUALLY, BEFORE THE RAINY
SEASON BEGINS
9 INSPECT AND, IF NEEDED, REPLACE WOOD MULCH. IT IS RECOMMENDED THAT 2" TO 3" OF COMPOSTED ARBOR MULCH BE APPLIED ONCE A YEAR.
ANNUALLY, BEFORE THE RAINY
SEASON BEGINS
10 INSPECT SYSTEM FOR EROSION OF BIOTREATMENT SOIL MEDIA, LOSS OF MULCH, STANDING WATER, CLOGGED OVERFLOWS, WEEDS, TRASH AND DEAD PLANTS. IF USING ROCK MULCH, CHECK FOR 3” OF COVERAGE.
ANNUALLY AT THE END OF THE
RAINY SEASON AND/OR AFTER
LARGE STORM EVENTS,
11 INSPECT SYSTEM FOR STRUCTURAL INTEGRITY OF WALLS, FLOW SPREADERS, ENERGY DISSIPATORS, CURB CUTS, OUTLETS AND FLOW SPLITTERS.
ANNUALLY AT THE END OF THE
RAINY SEASON AND/OR AFTER
LARGE STORM EVENTS,
STORMWATER
CONTROL
CALCULATIONS
MKD
NOT TO SCALE
MKD
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900SW.DWG
657900SW.DWG
5.2 6579.00
NOV. 20, 2023
26 PLOTTED: 10/8/2024 12:28 PMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
RH
10/11/2024
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
NO
PARKING
VAN
ACCESSIBLE
W
W
W
2"W
F
FF
6"FW
F
F
6"FW
F F
6"FW
6"FW
PROPOSED
FDC
EXISTING
PUBLIC
HYDRANT
EX 16"W
EX 12"W
HAYES AVE
ENDICOTT BLVD
SOUTHERN PACIFIC TRANSPORTATION COMPANY
EXISTING LANDS OF GBR MAGIC
SANDS MHP LLC
690-020-002
EXISTING LANDS OF SOUTHERN
PACIFIC TRANSPORTATION CO
690-020-002
PROPOSED BUILDING
±5,000 SF
BLOSSOM HILL ROAD
CONSTRUCT NEW
ACCESSIBLE RAMP PER
CSJ STDS.
CONSTRUCT NEW 32.0' WIDE
DRIVEWAY PER CSJ STDS
NEW PUBLIC SIDEWALK TO CONFORM
WITH EXISTING SIDEWALK
CONSTRUCT NEW PUBLIC DETACHED
SIDEWALK, CURB AND GUTTER
PER CSJ STDS
15'
BUILDING
SETBACK
LOT 1
±40,931 SF
PROPOSED
EMPLOYEE
PARKING
EXISTING LANDS OF LEE JAMES D
690-03-001
PROPOSED ADA ACCESS
(WITH MAN GATE) TO
PUBLIC RIGHT OF WAY PER
CSJ DESIGN GUIDELINES
PROPOSED TRASH
ENCLOSURE
LOCATE AND PROTECT SIGNAL INTERCONNECT
(SIC) COPPER CABLES (25 STRANDS RUNNING
ALONG ENDICOTT BLVD).
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
EXISTING
RESIDENTIAL
USE
7' WROUGHT IRON
SECURITY GATE
(TO REMAIN OPEN DURING
OPERATIONAL HOURS)
7'
WROUGHT
IRON
SECURITY
FENCE
EXISTING 6' TALL
MASONRY WALL
TO REMAIN
194'
111'
115'
147'
37'
77'
EXISTING 6' TALL
MASONRY WALL
TO REMAIN
CONSTRUCT NEW C3
BIORETENTION PLANTER
CONSTRUCT NEW C3
BIORETENTION PLANTER
NEW
PUBLIC
HYDRANT
FIRE ACCESS
PLAN
OB
AS SHOWN
OB
1 INCH = 20 FEET
4020 10 0
PROJECT BOUNDARY
LEGEND
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900FA.DWG
657900FA.DWG
6.0 6579.00
NOV. 20, 2023
26 PLOTTED: 10/8/2024 12:33 PMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
PROPOSED BUILDING
RH
30'/50' TURNING RADIUS
FIRE HYDRANT (E)
FIRE DEPARTMENT CONNECT (P)
EXISTING WATER LINE
FIRE DEPARTMENT LINE (PROPOSED)
EX 6"W
6"FW
150' HOSE PULL
BUILDING INFORMATION:
· BUILDING CONSTRUCTION TYPE: V-B
· BUILDING SF: 5,128 SF (MEASURED TO EXTERIOR WALL)
· HAZARD CLASSIFICATION: LIGHT HAZARD
· OCCUPANCY GROUPS: B , S-1
· BUILDING HEIGHT: 25' - 6”
10/11/2024
FH-1
FH-2
1. FLOW FH-1 AND FH-2 SIMULTENOUSLY FOR
1,500 GPM AT 20 PSI. EACH HYDRANT SHALL
FLOW MINIMUM 1,000 GPM IF FLOW INDIVIDUALLY.
SAN JOSE FIRE DEPARTMENT
REVIEWED
By: Date:
Kathy Tee
10/23/2024
CP24-001
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
EX 8"SS
EX12"SS
EX12"SS
EX 12"SD
EX 12"SD
EX 12"SD
EX 12"SD
EX 16"W
EX 12"W
N00°08'58"E 264.68'
S89°40'07"E 64.23'
S52°23'47"E 91.98'
L=85.77'
Δ=36°24'09"
S00°08'58"W 57.48'
L=107.02'
Δ=24°14'11"
N89°40'14"W 89.51'
EXISTING LANDS OF SOUTHERN
PACIFIC TRANSPORTATION CO
690-020-002
HAYES AVE
SOUTHERN PACIFIC TRANSPORTATION COMPANY
N00°08'58"E 264.68'
S89°40'07"E 64.23'
S52°23'47"E 91.98'
L=85.77'
Δ=36°24'09"
S00°08'58"W 57.48'
L=107.02'
Δ=24°14'11"
N89°40'14"W 89.51'
EXISTING LANDS OF SOUTHERN
PACIFIC TRANSPORTATION CO
690-020-002
PROPOSED BUILDING
±5,000 SF
NO
PARKING
VAN
ACCESSIBLE
BLOSSOM HILL ROAD
28'
30'
36'
PROPOSED TRASH
ENCLOSURE
50'
30'
R50'
R34'
SOUTHERN PACIFIC TRANSPORTATION
COMPANY
HAYES AVE
ENDICOTT BLVD
BLOSSOM HILL RD
BLOSSOMHILL RD
SITE
EX 8"SS
EX12"SS
EX12"SS
EX 12"SD
EX 12"SD
EX 12"SD
EX 12"SD
EX 16"W
EX 12"W
N00°08'58"E 264.68'
S89°40'07"E 64.23'
S52°23'47"E 91.98'
L=85.77'
Δ=36°24'09"
S00°08'58"W 57.48'
L=107.02'
Δ=24°14'11"
N89°40'14"W 89.51'
EXISTING LANDS OF SOUTHERN
PACIFIC TRANSPORTATION CO
690-020-002
HAYES AVE
SOUTHERN PACIFIC TRANSPORTATION COMPANY
N00°08'58"E 264.68'
S89°40'07"E 64.23'
S52°23'47"E 91.98'
L=85.77'
Δ=36°24'09"
S00°08'58"W 57.48'
L=107.02'
Δ=24°14'11"
N89°40'14"W 89.51'
EXISTING LANDS OF SOUTHERN
PACIFIC TRANSPORTATION CO
690-020-002
PROPOSED BUILDING
±5,000 SF
NO
PARKING
VAN
ACCESSIBLE
BLOSSOM HILL ROAD
28'
30'
36'
PROPOSED TRASH
ENCLOSURE
50'
30'
R50'
R34'
WASTE
MANAGEMENT
ACCESS PLAN
MKD
AS SHOWN
MKD
1 INCH = 20 FEET
4020 10 0
VICINITY MAP
SCALE: 1" = 500'
PROJECT BOUNDARY
LEGEND
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\PL\PERMIT\657900WM.DWG
657900WM.DWG
7.0 6579.00
NOV. 20, 2023
26 PLOTTED: 6/17/2024 2:57 PMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
PROPOSED BUILDING
EXISTING CURB AND GUTTER
PROPOSED PARKING
PROPOSED FACE OF CURB
EXISTING FENCE
BUILDING SETBACK
BIOTREATMENT AREA
PROPOSED SIDEWALK
PROPOSED FENCE
PROPOSED SIDEWALK EASEMENT
RH
WASTE MANAGEMENT-SITE ACCESS IN WASTE MANAGEMENT-SITE ACCESS OUT
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
NO PARKING
VAN ACCESSIBLE
PROPERTY LINE
ACCESSIBLE PATH OF TRAVEL:
48" MIN CLR. WIDTH, 5% MAX RUNNING
SLOPE, AND 2% MIN CROSS SLOPE
PER 2022 CBC 11B-403
# PARKING TOTAL
DS PROPOSED DOWNSPOUT
SETBACK
15' - 0"
HAYES AVE
ENDICOTT BLVD
DS
DS
PA5
1 PA6
2 PA5
2 PA6
1 PA2
11 (N) LANDSCAPE, SCD.
(N) SIDEWALK, SCD.
(N) LANDSCAPE, SCD.
(N) SIDEWALK, SCD.
50' - 3"
(N) FENCE, SCD.
(N) FENCE, SCD.
(N) ACCESS DOOR, SCD.
(N) ACCESSIBLE PATH
OF TRAVEL, SCD.
(N) GATE, SCD.
90' - 10"
PROPOSED
BUILDING
PA7
150' - 0" MIN.
DS
6 3
(N) LANDSCAPE, SCD.
(N) LANDSCAPE,
SCD.
(N) ACCESSIBLE
PATH OF TRAVEL,
SCD.
(N) BIKE
RACK, SCD.
(N) TREE, SCD.
(N) MECHANICAL
UNIT, SCD.
71' - 7"
LEGEND
DATE DESCRIPTIONNO
657800BR.DWG
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
CONDITIONAL USE PERMIT
XXOF
PA1
PROPOSED
SITE PLAN
10/19/2023
23064
EK
AE
15 COTTLE ROAD SAN JOSE
15 COTTLE ROAD
1/16" = 1'-0" 1
PROPOSED ARCHITECTURAL SITE PLAN
APPROVAL STAMPS
28 Exhibit E - Project Plans
OF PARKING STALL
ALIGN LOWER SIDE OF
SYMBOL W/ FRONT OF
PARKING STALL
PAINTED WHITE PROFILE
OVER BLUE BACKGROUND
1' - 6" 1' - 6"
3' - 0"
(2) #6 GALV. DOWELS 24"
LONG, 9" FROM EACH
END OF BUMPER
PRECAST CONC. WHEEL STOP
3'-0" LONG W/ (2) #3 BARS
ASPHALTIC CONC. PAVING
OVER AGGREGATE BASE
3" 2" 3"
3"3"
3' - 0" 1' - 0"
3" 2" 3"
2' - 6"
EDGE OF PARKING STALL
WHEEL STOP
2 PA2
SECTION
PLAN VIEW
TOP DIAMETER OF 0.45"-0.47"
BASE DIAMETER OF 0.9"-0.92"
2.3"-2.4"
2.3"-2.4"
0.65" MIN 0.18"-0.22"
NOTE: DETECTABLE
WARNING SURFACES SHALL
BE YELLOW AND
APPROXINATE FS 33,538 OF
FEDERAL STANDARD 595C
(CBC 11B-705.1.1.3)
CONC. FOOTING
THREADED PIPE CAP
2" ~ GALV. STL. PIPE - EMBED
18" MIN. INTO CONC. FOOTING
1' - 0"
17" MIN
22" MIN
MACHINE SCREWS T&B AND
WASHERS (TYP 4 PLACES)
ALUMINUM OR STEEL SIGN WITH 1 INCH HIGH
WHITE BEADED TEXT ON BLUE BACKGROUND:
"UNAUTHORIZED VEHICLES PARKED IN
DESIGNATED ACCESSIBLE SPACES NOT
DISPLAYING DISTINGUISHING PLACARDS OR
SPECIAL LICENSE PLATES ISSUED FOR
PERSONS WITH DISABILITIES WILL BE TOWED
AWAY AT THE OWNER'S EXPENSE. TOWED
VEHICLES MAY BE RECLAIMED AT: ___________
OR BY TELEPHONING___________"(NOTE:
BLANK SPACES SHALL BE FILLED IN WITH
APPROPRIATE INFORMATION PRIOR TO
FABRICATION)
2' - 0" 6' - 8"
CONC. FOOTING
THREADED PIPE CAP
INTERNATIONAL SYMBOL OF
ACCESSIBILITY
REFLECTORIZED SIGN -
WHITE ON DARK BLUE
BACKGROUND (70 SQ. IN. MIN.)
VAN ACCESSIBLE SIGN (AT
VAN ACCESSIBLE STALL)
2" ~ GALV. STL. PIPE - EMBED
18" MIN. INTO CONC. FOOTING
1' - 0"
12"
30"
MACHINE SCREWS T&B AND
WASHERS (TYP 4 PLACES)
"MINIMUM FINE $250" SIGN
BELOW INTERNATIONAL SIGN
OF ACCESSIBILITY PER CBC
11B-502.6.2
2' - 0"
PARKING
ONLY
MINIMUM
FINE $250
PARKING
ONLY
MINIMUM
FINE $250
VAN
ACCESSIBLE
12"
24"
60" MIN
60" MIN
NOTE: (PER CBC11B-502.6)
SIGNS SHALL BE 60 INCHES MIN. ABOVE THE
FINISH FLOOR OR GROUND SURFACE
MEASURED TO THE BOTTOM OF THE SIGN.
*EXCEPTION: SIGNS LOCATED WITHIN A
CIRCULATION PATH SHALL BE A MIN. OF 80
INCHES ABOVE THE FINISH FLOOR OR
GROUND SURFACE MEASURED TO THE
BOTTOM OF THE SIGN.
4" WIDE DIAGNOL STRIPING AT 3'-0"
O.C. MAX., TWO COATS (TYP) COLOR
TO BE WHITE OR BLUE REFLECTIVE
HIGHWAY PAINT
PERIMETER 4" WIDE STRIPING, TWO
COATS (TYP) COLOR TO BE BLUE
REFLECTIVE HIGHWA PAINT
NOTE:
ALL PRIMARY AND CROSS SLOPE CONDITIONS
SHALL COMPLY WITH ACCESSIBLE ROUTE TO
TRAVEL CRITERIA PER STATE OF CA TITLE 24
ACCESSIBILITY STANDARDS
TYP
4' - 0" MIN MAX
36"
NOTE - ACCESS AISLE SHALL COMPLY
WITH CBC 2019 REF. 11B-502.3
45°
CONCRETE SIDEWALK
BROOM FINISH CONCRETE
TAPER CURB ON
BOTH SIDES OF
ACCESSIBLE RAMP
4" WIDE STRIPING
TWO COATS (TYP.)
TO MATCH
EXISTING SITE
STRIPING COLOR
NO PARKING
PAINT "NO
PARKING", MIN. 12"
HIGH LETTERS W/
(2) COATS OF
TRAFFIC WHITE
5' - 0"
CURB
TOP OF EDGE OF
CURB AT ACCESSIBLE
RAMP SHALL BE
FLUSH WITH THE
DRIVEWAY PAVING
REFER TO
DETAIL FOR
ACCESS AISLE
REQUIREMENTS
NOTE:
• THE PARKING STALL AND ACCESS AISLE SHALL HAVE A MAXIMUM SLOPE OF 2% IN ANY DIRECTION
• PARKING STALLS SHALL COMPLY WITH CBC 2022 11B-208 AND 11B-502 6' - 0" TYP
ACCESSIBLE STALL
9' - 0" VAN
/10 PA2
PA2
1 PA2
8 PA2
14 EQ EQ
18' - 0" MIN
9'-0" STANDARD STALL
6' - 0" U.O.N.
U.O.N.
3' - 0"
THE CURB RAMP
LANDING WIDTH
AT LEAST AS WIDE AS
BROOM FINISH ACCESSIBLE
RAMP SURFACE AND SIDE
FLARES
THE SLOPE OF THE RAMP
LA
NDING IN ALL DIRECTIONS
SHALL BE 1:48 MAX
THE RAMP CROSS SLOPE SHALL
BE 1:48 MAX
12" MIN. BORDER
GROOVES PER DETAIL
DETECTABLE WARNING
SURFACE PER DETAIL
FOR THE FULL WIDTH OF
THE CURB RAMP
TOP OF EDGE OF THE CURB
AT ACCESSIBLE RAMP SHALL
BE FLUSH WITH THE
DRIVEWAY PAVING
AS OCCURS
AS OCCURS
4' - 0" MIN
WIDTH AS OCCURS
TAPER CURB ON
BOTH SIDES OF
ACCESSIBLE RAMP,
PAINT BLUE, TYP
ADJOINING
SLOPE
1:20 MAX.
WITHIN 20"
NOTE: CURB RAMPS SHALL COMPLY WITH CBC 2022 REFER TO 11B-406 /5 PA2
/- ---
RAMP
1:12 MAX
1:10 MAX1:10 MAX
1' - 6"
4" WIDE BAND OF
REFLECTORIZED TAPE
4" OUTSIDE DIA SCHEDULE 40 GALV
PI
PE FILLED W/ GROUT, PAINT,
SAFETY YELLOW
1" HIGH SLOPE AWAY FROM BOLLARD
CONCRETE FOOTING
6"
6" 7' - 6"
ADJACENT SURFACE
CONCRETE CROWN
4"
DATE DESCRIPTIONNO
657800BR.DWG
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
CONDITIONAL USE PERMIT
XXOF
PA2
SITE
AC
CESSIBILITY
10/19/2023
23064
EE
JE
15 COTTLE ROAD SAN JOSE
15 COTTLE ROAD
1" = 1'-0" 1
ACCESSIBLE SYMBOL
1 1/2" = 1'-0" 2
WHEEL STOP SECTION DETAIL
1" = 1'-0" 3
WHEEL STOP PLAN DETAIL
3" = 1'-0" 5
TRUNCATED DOME DETAILS
3/4" = 1'-0" 4
ENTRANCE ACCESSIBLE SIGNAGE
3/4" = 1'-0" 8
ACCESSIBLE PARKING SIGNAGE - POLE MOUNTED
NS 10
ADA PATH OF TRAVEL
NS 11
ACCESSIBLE PARKING STALLS
NS 14
ACCESSIBLE PERPENDICULAR CURB RAMP
1/2" = 1'-0" 15
BOLLARD
28 Exhibit E - Project Plans
7' - 9" 25' - 4" 11' - 8" 5' - 5"
3' - 0" 12' - 8" 23' - 7" 11' - 0"
23' - 9" 20' - 3" 18' - 2" 8' - 5" 5' - 11" 12' - 7" 3' - 0" R1
R1
R1R1R1R1
S1
S1S1S1
S1
S1
22' - 9"
35' - 11"
4' - 0".
4' - 0".
16.02 16.01
4' - 7" 4' - 7"
S1
DATE DESCRIPTIONNO
657800BR.DWG
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
CONDITIONAL USE PERMIT
XXOF
PA3
PROPOSED
LIGHTING
PLAN
10/19/2023
23064
EK
AE
15 COTTLE ROAD SAN JOSE
15 COTTLE ROAD
S1 LITHONIA TWR2-LED-1-50K-MVOLT-DDB LED WALL 69 0 DEGREE BALLAST, WALL PAK W/ GLASS REFLECTOR; CAST ALUM HOUSING 16'-0" AFF R1 LITHONIA OL CFM-15-WH LED RECESSED 16.6 SURFACE MOUNTED LED AND WET LABEL TYPE MANUF. DI FFUSER LAMPS MOUNTING WATTS REMARKS
LIGHTING FIXTURE SCHEDULE
APPROVAL STAMPS
KEYNOTES
16 .01 SIGNAGE UNDER SEPARATE PERMIT OWNER FURNISHED
SIGNAGE (GC TO COORDINATE AND PROVIDE ELEC.
REQUIREMENTS & 3/4" EXT. FT PLYWOOD SHEATHING
BEHIND PANELS @ SIGNAGE LOCATIONS)
16.02 SIGNAGE UNDER SEPARATE PERMIT, OWNER FURNISHED
SIGNAGE (GC TO COORDINATE AND PROVIDE ELEC.
REQUIREMENTS)
1/4" = 1'-0" 1
PROPOSED LIGHTING PLAN
28 Exhibit E - Project Plans
1 2 3 4 5 6
A
B
C
D
50' - 0"
102' - 0"
2' - 0"16' - 5"2' - 0"11' - 7"
12' - 1" 4' - 0" 8' - 3" 4' - 0" 3' - 8"
2' - 0"12' - 7"5' - 4"6' - 0"5' - 4"16' - 9"2' - 0"
STORAGE
123
BREAK ROOM
104
CONFERENCE
102
MEN'S
122
WOMEN'S
121
DISPLAY AREA
101
SHOP OFFICE
108
MANAGER
120
WAREHOUSE
110
PRESSURE
WASHER ROOM
112
LARGE WASH
BAY
111
EXISTING WALL
NEW WALL , REFER TO WALL LEGEND TYPE
EXISTING DOOR
PROPOSED WINDOW / STOREFRONT
PROPOSED DOOR
DATE DESCRIPTIONNO
657800BR.DWG
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
CONDITIONAL USE PERMIT
XXOF
PA4
PROPOSED
FLOOR
PLAN
10/19/2023
23064
EK
AE
15 COTTLE ROAD SAN JOSE
15 COTTLE ROAD
1/4" = 1'-0" 1
PROPOSED FLOOR PLAN
LEGEND APPROVAL STAMPS
28 Exhibit E - Project Plans
LEVEL 1
0' - 0"
1 2 3 4 5 6
T.O. PARAPET
24' - 0"
T.O. TOWER
25' - 6"
102' - 0"
11' - 7" 2' - 0"
BIRD SAFETY FILM APPLIED, SEE KEYNOTE 08.05
16' - 5" 2' - 0" 4' - 0"
8' - 0"
1' - 11"8' - 1"
7' - 0"
14' - 0"
A
12' - 0"
CD
B
EFG
H
16.01 N 08.02
21.01 08.03KJ
16' - 0"
16.03 08.05
32' - 0"50' - 4"19' - 9"
4' - 1"4' - 1"4' - 1"4' - 1"3' - 10"3' - 10"3' - 10"
T.O. PARAPET
22' - 2"
LEVEL 1
0' - 0"
ABCD
T.O. PARAPET
24' - 0"
T.O. TOWER
25' - 6"
50' - 0"
3' - 11" 2' - 0"
BIRD SAFETY FILM APPLIED, SEE KEYNOTE 08.05
16' - 9" 5' - 4" 6' - 0" 5' - 4"
BIRD SAFETY FILM APPLIED, SEE KEYNOTE 08.05
12' - 7" 2' - 0"
10' - 0"
8' - 0" 2' - 0"
A
BC C
E
F
A
G
H
12' - 0"
N08.01 N08.02
08.03 16.02
21.01 12' - 0"
16.03 08.05 08.05
T.O. PARAPET
22' - 2"
14' - 0" 8' - 2"
2' - 8" 2' - 8" 6' - 2" 2' - 8" 2' - 8"
18' - 9" 16' - 9" 14' - 7"
3' - 0" 3' - 0" 3' - 2" 3' - 2" 3' - 2" 3' - 2"
COLOR:
C STANDING SEAM METAL SIDING- ACCENT
NA22-0019 / SUNBELT RENTALS GREEN
MANUFACTURER: STO
PRODUCT#: 648 STOCOLOR ACRYL PLUS
COLOR:
E CANOPY FASCIA
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
F METAL WALL TRIM CAPS
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
A BRICK VENEER
BROWN
MANUFACTURER: TBD
SIZE: (4 X 4 H X 16)
COLOR:
B SPLIT FACE CMU VENEER W/ DRY BLOK ADDITIVE
GRAY
MANUFACTURER: TBD
SIZE: (12 X 8 H X16)
COLOR:
G METAL COPING
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
H ALUMINUM STOREFRONT MULLION
CLEAR ANODIZED
MANUFACTURER: TBD
SIZE: 4 1/2" X 2"
COLOR:
I LOUVERED VENTS
SW 7017 DORIAN GRAY
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
D STANDING SEAM METAL SIDING- WAREHOUSE
SW 7017 DORIAN GRAY
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
J HOLLOW METAL DOOR
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
K OVERHEAD DOOR
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
L PRE-FINISHED GALV. METAL GUTTER
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
M PRE-FINISHED GALV. METAL DOWNSPOUT
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
N CLEAR GLAZING
CLR
MANUFACTURER: TBD
X EXTERIOR FINISH TAG, REFER TO
MATERIAL LEGEND
SHADED AREA
C
A
B
N
NORTH ARTICULATION %
C
A
D
N
EAST ARTICULATION %
154 SF 13%
335 SF 28%
372 SF 31%
268 SF 22%
TOTAL: 1,204 SF TOTAL: 2,324 SF
212 SF 9%
282 SF 12%
849 SF 37%
280 SF 12%
K 532 SF 23%
J 25 SF 1%
DATE DESCRIPTIONNO
657800BR.DWG
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
CONDITIONAL USE PERMIT
XXOF
PA5
PROPOSED
EAST &
NORTH
EXTERIOR
ELEVATIONS
10/19/2023
23064
EK
AE
15 COTTLE ROAD SAN JOSE
15 COTTLE ROAD
1/4" = 1'-0" 1
PROPOSED EAST ELEVATION
1/4" = 1'-0" 2
PROPOSED NORTH ELEVATION
APPROVAL STAMPSMATERIAL LEGEND
KEYNOTES
08 .01 STOREFRONT DOOR, 1" CLEAR INSULATING GLASS (LOW "E" / TEMPER AS REQUIRED BY CODE), TYP.
08.02 STOREFRONT WINDOW SYSTEM, 1" CLEAR INSULATING
GLASS (LOW "E" / TEMPER AS REQUIRED BY CODE), TYP.
08.03 8" PREFIN. CONC. LINTEL BEARING ON STL ANGLE LINTEL, TYP. AT WINDOWS.
08.05 BIRD SAFETY WINDOW FILM APPLIED ON AREAS OF GLAZING WITHIN 10 FEET OF A BUILDING CORNER; SOLYX SX-BSFD
FROST DOT BIRD SAFETY FILM (NO MIRRORED GLASS OR
GLAZING WITH REFLECTIVE INDEX ABOVE 20% ALLOWED),
SEE LINK FOR DETAIL
https://www.decorativefilm.com/sx-bsfd-frost-dot-bird-safety-film
16.01 SIGNAGE UNDER SEPARATE PERMIT OWNER FURNISHED
SIGNAGE (GC TO COORDINATE AND PROVIDE ELEC.
REQUIREMENTS & 3/4" EXT. FT PLYWOOD SHEATHING
BEHIND PANELS @ SIGNAGE LOCATIONS)
16.02 SIGNAGE UNDER SEPARATE PERMIT, OWNER FURNISHED
SIGNAGE (GC TO COORDINATE AND PROVIDE ELEC.
REQUIREMENTS)
16.03 SURFACE MOUNTED EXTERIOR LIGHTING, TYP.
21.01 CANOPY, DARK GRAY METAL, TYP.
LEGEND
ARTICULATION
28 Exhibit E - Project Plans
LEVEL 1
0' - 0"
A B C D
LOW ROOF
19' - 6"
T.O. PARAPET
24' - 0"
T.O. TOWER
25' - 6"
8' - 0"
14' - 7"
B
D
G I F
10' - 0"
T.O. PARAPET
22' - 2"
4' - 0" 50' - 3" 4' - 0"
LEVEL 1
0' - 0"
123456
LOW ROOF
19' - 6"
T.O. PARAPET
24' - 0"
T.O. TOWER
25' - 6"
8' - 0"
12' - 1"4' - 0"8' - 3"4' - 0"3' - 8"4' - 0"
10' - 0"
A B
C D
E
F G
H
I
N 08.02
08.03 L
M
45°
4' - 0"
12' - 0"
24 SF GLAZING,
9 SF SHADED, OK.
24 SF GLAZING,
9 SF SHADED, OK.
08.05 BIRD SAFETY FILM APPLIED,
SEE KEYNOTE 08.05
T.O. PARAPET
22' - 2"
32' - 0" 50' - 3" 19' - 9"
102' - 0"
COLOR:
C STANDING SEAM METAL SIDING- ACCENT
NA22-0019 / SUNBELT RENTALS GREEN
MANUFACTURER: STO
PRODUCT#: 648 STOCOLOR ACRYL PLUS
COLOR:
E CANOPY FASCIA
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
F METAL WALL TRIM CAPS
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
A BRICK VENEER
BROWN
MANUFACTURER: TBD
SIZE: (4 X 4 H X 16)
COLOR:
B SPLIT FACE CMU VENEER W/ DRY BLOK ADDITIVE
GRAY
MANUFACTURER: TBD
SIZE: (12 X 8 H X16)
COLOR:
G METAL COPING
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
H ALUMINUM STOREFRONT MULLION
CLEAR ANODIZED
MANUFACTURER: TBD
SIZE: 4 1/2" X 2"
COLOR:
I LOUVERED VENTS
SW 7017 DORIAN GRAY
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
D STANDING SEAM METAL SIDING- WAREHOUSE
SW 7017 DORIAN GRAY
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
J HOLLOW METAL DOOR
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
K OVERHEAD DOOR
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
L PRE-FINISHED GALV. METAL GUTTER
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
M PRE-FINISHED GALV. METAL DOWNSPOUT
WEB GRAY SW 7075
MANUFACTURER: SHERWIN-WILLIAMS
COLOR:
N CLEAR GLAZING
CLR
MANUFACTURER: TBD
X EXTERIOR FINISH TAG, REFER TO
MATERIAL LEGEND
SHADED AREA
A
D
SOUTH ARTICULATION %
C
A
D
N
WEST ARTICULATION %
402 SF 39%
529 SF 51%
TOTAL: 1,032 SF TOTAL: 2,076 SF
544 SF 26%
223 SF 11%
1,080 SF 52%
56 SF 3%
DATE DESCRIPTIONNO
657800BR.DWG
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
CONDITIONAL USE PERMIT
XXOF
PA6
PROPOSED
WEST &
SOUTH
EXTERIOR
ELEVATIONS
10/19/2023
23064
EK
AE
15 COTTLE ROAD SAN JOSE
15 COTTLE ROAD
1/4" = 1'-0" 2
PROPOSED SOUTH ELEVATION
1/4" = 1'-0" 1
PROPOSED WEST ELEVATION
KEYNOTES
08 .02 STOREFRONT WINDOW SYSTEM, 1" CLEAR INSULATING
GLASS (LOW "E" / TEMPER AS REQUIRED BY CODE), TYP.
08.03 8" PREFIN. CONC. LINTEL BEARING ON STL ANGLE LINTEL, TYP. AT WINDOWS.
08.05 BIRD SAFETY WINDOW FILM APPLIED ON AREAS OF GLAZING WITHIN 10 FEET OF A BUILDING CORNER; SOLYX SX-BSFD
FROST DOT BIRD SAFETY FILM (NO MIRRORED GLASS OR
GLAZING WITH REFLECTIVE INDEX ABOVE 20% ALLOWED),
SEE LINK FOR DETAIL
https://www.decorativefilm.com/sx-bsfd-frost-dot-bird-safety-film LEGEND
APPROVAL STAMPSMATERIAL LEGEND
ARTICULATION
28 Exhibit E - Project Plans
LEVEL 1
0' - 0"
PEDESTRIAN ACCESS DOOR
PROVIDE INTERMED. 2x2 T.S.
SUPPORT (VERT/HORIZ)
9 PA7
8 PA7
LEVEL 1
0' - 0"
1/2" / 12"
9' - 8"
8' - 0"
CMU BLOCK WALL w/ PAINT
FINISH TO MATCH ADJ. BLDG.
CORRUGATED MTL. ROOF w/ GALV. SHT.
MTL. FLASHING w FASTENER &
NEOPRENE WASHER PRIME & PAINT ALL
MTL. TO MATCH CMU
H.S.S. FRAME w/ BASE PLATE
ATTACHED TP WALL w/ EXP/
BOLTS, PRIME & PAINT
1/2" / 12"
3/4" DIA. CANE BOLT
CORRUGATED MTL. DECKING
GATE, PRIME & PAINT
3/4" DIA. DROP BOLT
1X1 SQ. TUBING WELDING
DIAG. TO DOOR FRAME,
PRIME & PAINT
PA7
6 7
PA7
0' - 6"
0' - 6"
INTEGRALLY
COLORED SPLIT FACE
CMU WALL. S.S.D.
CONCRETE CURB S.S.D.
CONCRETE HATCH
FRAME DOOR. 4 SIDES W/L WELDED, S.S.D.
3 PR. OF HEAVY-DUTY BUTT HINGES
WELDED TO JAMB AND GATE FRAME
3/4" DIAMETER SLIDE BOLT W/RECEIVER
1" CORRUGATED STEEL DECKING,
WELD TO FRAME, S.S.D.
1" MIN. CLEAR (1/2" MAX.)
H.S.S. GATE COLUMN, S.S.D.
METAL L SECTION DIAGNAL BRACE, S.S.D.
INTEGRALLY COLORED SPLIT FACE CMU
3/4" DIAMETER CANE BOLT & GUIDES
INTEGRALLY COLORED SPLIT
FACE CMU WALL. S.S.D.
FLAT CMU CAP, INTEGRALLY COLORED
HSS COLUMN S.S.D.
0' - 8"
HSS BEAM S.S.D.
CORRUGATED METAL ROOF
W/
NEOPRENE WASHER AT FASTENERS
PRIME & PAINT, TYP. S.S.D.
1' - 0"
2/ PA7
3/ PA7
4/ PA7
5/ PA7
13' - 10"
10' - 9"
15' - 1"
12' - 0"
WASTE
DUMPSTER
RECYCLE
DUMPSTER
42"30"42"
SLOPE 2% MIN.
SLOPE 2% MIN.
SLOPE 2% MIN.
SLOPE 2% MIN.
3' - 11"
DATE DESCRIPTIONNO
657800BR.DWG
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
CONDITIONAL USE PERMIT
XXOF
PA7
SITE
DETAILS
10/19/2023
23064
EK
AE
15 COTTLE ROAD SAN JOSE
15 COTTLE ROAD
1/4" = 1'-0" 2
TRASH ENCLOSURE - EAST ELEVATION
1/4" = 1'-0" 3
TRASH ENCLOSURE - NORTH ELEVATION
1/4" = 1'-0" 4
TRASH ENCLOSURE - WEST ELEVATION
1/4" = 1'-0" 5
TRASH ENCLOSURE - SOUTH ELEVATION
1/4" = 1'-0" 6
HORIZ LATCH DETAIL
1" = 1'-0" 8
TRASH ENCL. WALL SECTION @ BASE
1" = 1'-0" 7
TRASH ENCL. GATE JAMB
1" = 1'-0" 9
TRASH ENCL. WALL SECTION @ TOP
1/4" = 1'-0" 1
TRASH ENCLOSURE ENLARGED PLAN
28 Exhibit E - Project Plans
DATE DESCRIPTIONNO
657800BR.DWG
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
CONDITIONAL USE PERMIT
XXOF
PA8
PROPOSED
EXTERIOR
RENDERING
10/19/2023
23064
EK
AE
15 COTTLE ROAD SAN JOSE
15 COTTLE ROAD
28 Exhibit E - Project Plans
IC
BLOSSOM HILL ROAD
HAYES AVE
EXISTING LANDS OF SOUTHERN
PACIFIC TRANSPORTATION CO
SOUTHERN PACIFIC TRANSPORTATION COMPANY
PROPOSED
BUILDING
OFFICES
WAREHOUSE
MAINTENANCE
PARKING
PARKING
TRASH
ENCLOSURE
9'-9"
7'-2"
15'-0" TYP.
17'-0" TYP.
25' MAX, TYP.
25' MAX, TYP.
5'-6"
1'-6"
14'-0"
5'-0"
20'-2"
24'-3"
21'-8"
22'-10"
25'-0"
8'-2"
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\LA\PLANNING\657900CL.DWG
657900CL.DWG
L10.1
6579.00
NOV. 20, 2023
27 PLOTTED: 2/4/2025 9:12 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
LANDSCAPE PLAN
NOTES:
1. SEE SHEET L10.1 FOR LANDSCAPE PLAN.
2. SEE SHEET L10.2 FOR PLANTING LEGEND, NOTES, AND TREE MITIGATION TABLE.
3. SEE SHEET L10.3 FOR PLANTING DETAILS.
4. SEE SHEET L10.4 FOR HYDROZONE PLAN.
5. SEE SHEET L10.5 FOR IRRIGATION DETAILS.
6. SEE SHEETS L10.6 - L10.7 FOR CONCEPT IMAGES.
7. SEE SHEET L10.8 FOR TREE CANOPY COVERAGE PLAN.
8. STREET TREES SHOWN CONCEPTUALLY. FINAL SELECTION TO BE COORDINATED WITH THE CITY ARBORIST.
9. STREET TREE TO BE APPROVED BY CITY ARBORIST. MAXIMUM DISTANCE FOR STREET TREES AS FOLLOWS:
20'-0" O.C. FOR SMALL STREET TREES
25'-0" O.C. FOR MEDIUM STREET TREES
35'-0" O.C. FOR LARGE STREET TREES
10.SITE TREE PLACEMENT MINIMUM DIMENSION REQUIREMENT:
5'-0" O.C. TO BUILDING STRUCTURE FOR SMALL STREET TREES 12'-0" O.C. TO BUILDING STRUCTURE FOR MEDIUM STREET TREES 20'-0" O.C. TO BUILDING STRUCTURE FOR LARGE STREET TREES
11.DESIGNATE 700 CUBIC FEET OF NON-COMPACTED SOIL FOR SMALL TREES, 1400 CUBIC FEET OF NON-COMPACTED SOIL FOR MEDIUM TREES, AND 2100 CUBIC FEET OF NON-COMPACTED SOIL FOR LARGE TREES TO ALLOW TREES TO REACH THEIR MATURITY. STRUCTURAL SOIL SYSTEMS,
SOIL CELLS, OR CONTINUOUS TRENCHES ARE EXAMPLE OF WAYS TO REACH TO THE ABOVE SOIL VOLUMES.
12.MINIMUM VERTICAL CLEARANCE FOR TREE CANOPIES AT MATURITY AS FOLLOWS:
14'-0" IN AND AROUND SERVICE AND LOADING AREAS AND DRIVEWAYS 12'-0" FOR PARKING LOTS
8'-0" FOR TREE CANOPIES IMMEDIATELY
PROPOSED PLANT PALETTE
LAURUS NOBILIS 'SARATOGA'
(SMALL TREE)
TREE LEGEND:
LAGERSTROEMIA INDICA 'NATCHEZ'
(SMALL TREE)
SHRUB LEGEND:
GROUNDCOVER LEGEND:
SCALE: 1" = 20'
ULMUS PARVIFOLIA
(MEDIUM TREE)
LOMANDRA LONGIFOLIA 'BREEZE'
JUNCUS PATENS
LOMANDRA HYSTRIX 'TROPICBELLE'
NEPETA X FAASSENII
CEANOTHUS 'CONCHA'
VERBENA LILACENA 'DE LA MINA'
SALVIA CLEVELANDII
BIOTREATMENT AREA LEGEND:
ERIGERON KARVINSKIANUS
ARCTOSTAPHYLOS 'EMERALD CARPET'
CHONDROPETALUM ELEPHANTINUM
CHONDROPETALUM TECTORUM
ACER RUBRUM 'ARMSTRONG'
(MEDIUM TREE)
PROPERTY LINE
DRIVEWAY
EXISTING OVERHEAD UTILITY LINE
TO BE REDIRECTED TO PROPOSED
BUILDING
PROPOSED CONCRETE PAVING,
TYPICAL
ON-GRADE STORMWATER
TREATMENT PLANTER, TCM 7
STORMWATER TREATMENT
PLANTER, TCM 3
ON-GRADE STORMWATER
TREATMENT PLANTER, TCM 2
STORMWATER TREATMENT
PLANTER, TCM 1
STORMWATER TREATMENT
PLANTER, TCM 5
ON-GRADE STORMWATER
TREATMENT PLANTER, TCM 6
EXISTING 6'-0" HIGH METAL FENCE,
TYPICAL. SEE SHEET L10.9 FOR
FENCE AND GATE DETAILS
EXISTING 6'-0" HIGH
MASONRY WALL TO REMAIN
PROPOSED IRRIGATION
CONTROLLER
PROPOSED ADA ACCESS GATE
PER CSJ DESIGN GUIDELINES. SEE
SHEET L10.9 FOR FENCE AND GATE
DETAILS
EXISTING 6'-0" HIGH MASONRY
WALL TO REMAIN
STORMWATER TREATMENT
PLANTER, TCM 4
( In Feet )
1 inch = 20 feet
GRAPHIC SCALE
80402010020
2 TOTAL BICYCLE RACKS
1 BICYCLE LOCKER
PROTECTIVE VEHICULAR BOLLARDS
1" = 20'
JN
ST
ST
MALUS 'PRAIRIFIRE'
(SMALL TREE)
PEDESTRIAN GATE. SEE SHEET
L10.9 FOR FENCE AND GATE
DETAILS
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\LA\PLANNING\657900CL.DWG
657900CL.DWG
L10.2
6579.00
NOV. 20, 2023
26 PLOTTED: 1/28/2025 10:52 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
PLANTING LEGEND,
NOTES, AND TREE
MITIGATION TABLE
SHRUBS
DWARF MAT RUSHLOMANDRA LONGIFOLIA 'BREEZE' 3' X 3'1 GALLON L
GROUNDCOVERS SPACING
ERIGERON KARVINSKIANUS SANTA BARBARA DAISY 1 GALLON L@ 24" O.C.
PROPOSED PLANT PALETTE
TREES
SYMBOL QTY. BOTANICAL NAME COMMON NAME
MINIMUM
CONTAINER SIZEHxW
WUCOLS
(L, M, H)
114
8 ULMUS PARVIFOLIA9
JUNCUS PATENS COMMON RUSH 2' X 2'1 GALLON L147
4 PLANTING PLAN NOTES
CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT NECESSARY TO FURNISH AND INSTALL PLANT MATERIAL AS SHOWN ON THE DRAWINGS AND AS DESCRIBED IN THE SPECIFICATIONS.
UNLESS DESIGNATED ON THE DRAWINGS OTHERWISE, STRUCTURAL IMPROVEMENTS AND HARDSCAPE SHALL BE INSTALLED PRIOR TO PLANTING OPERATIONS.
PLANT LIST ON THE DRAWINGS SHALL BE USED AS A GUIDE ONLY. CONTRACTOR SHALL TAKEOFF AND VERIFY SIZES AND QUANTITIES BY PLAN CHECK.
A SOIL MANAGEMENT REPORT SHALL BE PROVIDED BY LANDSCAPE CONTRACTOR AND SOIL AMENDMENTS SHALL BE FOLLOWED PER THE REPORT. PHYSICAL COPIES OF THE SOIL MANAGEMENT REPORT SHALL BE PROVIDED TO THE CLIENT, PROJECT LANDSCAPE ARCHITECT AND LOCAL AGENCY AS REQUIRED. THE SOIL MANAGEMENT REPORT SHALL CONFORM TO STATE AB1881 WATER EFFICIENT LANDSCAPE ORDINANCE (WELO) OR LOCAL AGENCY ADOPTED WELO. CONTRACTOR SHALL OBTAIN A SOILS MANAGEMENT REPORT AFTER GRADING OPERATIONS AND PRIOR TO PLANT INSTALLATION.
SAMPLES OF FERTILIZERS, ORGANIC AMENDMENT, SOIL CONDITIONERS, AND SEED SHALL BE SUBMITTED PRIOR TO INCORPORATION. CONTRACTOR SHALL FURNISH TO THE OWNER'S AUTHORIZED REPRESENTATIVE A CERTIFICATE OF COMPLIANCE FOR SUCH FURNISHED MATERIALS.
ALL WORK ON THE IRRIGATION SYSTEM, INCLUDING HYDROSTATIC, COVERAGE, AND OPERATIONAL TESTS AND THE BACKFILLING AND COMPACTION OF TRENCHES SHALL BE PERFORMED PRIOR TO PLANTING OPERATIONS.
LOCATIONS OF PLANT MATERIAL SHALL BE REVIEWED ON SITE BY THE OWNER'S AUTHORIZED REPRESENTATIVE PRIOR TO INSTALLATION.
TREES SHALL BE PLANTED NO CLOSER THAN TEN FEET (10') FROM UTILITIES.
TREES PLANTED WITHIN FIVE FEET (5') OF HARDSCAPE OR STRUCTURES SHALL BE INSTALLED WITH A ROOT BARRIER AS APPROVED BY THE OWNER'S AUTHORIZED REPRESENTATIVE.
CONTRACTOR MUST CONTACT THE CITY OF SAN JOSE ARBORIST AT 408-794-1924 TO VERIFY SPECIES (EVEN IF SHOWN ON THE PLANS), LOCATIONS, AND QUANTITIES OF ALL STREET TREES PRIOR TO ORDERING MATERIAL. IF STREET TREES ARE
TO BE PLANTED IN TREE WELLS, FINAL LOCATION OF TREE WELLS SHALL BE DETERMINED BY THE ARBORIST PRIOR TO INSTALLATION OF SIDEWALK.
ALL PLANTING AREAS TO RECEIVE 3" THICK BARK MULCH LAYER. CONTRACTOR SHALL PROVIDE SAMPLE OF PROPOSED BARK MULCH FOR APPROVAL. BARK MULCH SHALL BE LYNGSO SMALL FIR BARK (3/4" TO 1-1/2") OR APPROVED EQUAL.
ALL PLANT MATERIAL SHALL BE SELECTED IN ACCORDANCE WITH THE AMERICAN STANDARD FOR NURSERY STOCK (ANSI Z60.1)
FOR STANDARD FORM TREES, CALIPER SIZE SHALL BE MEASURED 6" ABOVE THE SOIL LINE FOR CALIPERS EQUAL TO OR LESS THAN 4" FOR CALIPERS GREATER THAN 4", CALIPER SHALL BE MEASURES 12" ABOVE THE SOIL LINE. FOR
MULTI-TRUNK TREES THE CALIPER SHALL BE ESTABLISHED BY TAKING THE AVERAGE OF THE CALIPER OF THE TWO LARGEST TRUNKS.
CALIPER IS MEASURED 6” ABOVE ORIGINATION POINT OF THE SECOND LARGEST TRUNK OR 6” ABOVE GROUND IF ALL TRUNKS ORIGINATE FROM THE SOIL.
CALIPER SIZES STANDARDS:
15 GALLON: 0.75-1.25"
24" BOX: 1.25-2"
36" BOX: 2-3.5"
48" BOX: 3.5-5"
60" BOX: 4-6"
WATER NEEDS CATEGORY BASED ON WUCOLS IV (JANUARY 2014) LANDSCAPE COEFFICIENT METHOD:
CATEGORY PERCENTAGE OF ETo
(H) HIGH: 0.7-0.9
(M) MEDIUM: 0.4-0.6
(L) LOW: 0.1-0.3
(VL) VERY LOW:<0.1
NOTES:
1. BARK MULCH: ALL PLANTING AREAS TO RECEIVE A 3" THICK LAYER OF BARK MULCH.
2. BARK MULCH: ALL BIOTREATMENT AREAS TO RECEIVE A 3" THICK LAYER OF NON-FLOATABLE BARK MULCH.
3. THE LOCATIONS OF THE STREET TREES WILL BE DETERMINED AT THE STREET IMPROVEMENT STAGE. CONTACT THE CITY ARBORIST AT (408) 794-1901 FOR THE DESIGNATED STREET TREE. INSTALL STREET TREES WITHIN PUBLIC RIGHT-OF-WAY ALONG ENTIRE PROJECT STREET FRONTAGE PER CITY STANDARDS; REFER TO THE CURRENT “GUIDELINES FOR PLANNING, DESIGN, AND CONSTRUCTION OF CITY STREETSCAPE PROJECTS”. STREET TREES SHALL BE INSTALLED IN PARK STRIP. OBTAIN A DOT STREET TREE PLANTING PERMIT FOR ANY PROPOSED STREET TREE PLANTINGS. STREET TREES SHOWN ON THIS PERMIT ARE CONCEPTUAL ONLY.
4. ADJACENT PROPERTY OWNER IS RESPONSIBLE FOR ALL MAINTENANCE, IRRIGATION, AND PLANTING ON PARK STRIPS PER SJ MUNICIPAL CODE. CSJ IS ONLY RESPONSIBLE FOR MAINTENANCE OF OFFSITE BIORETENTION AREAS.
BIOTREATMENT
ARCTOSTAPHYLOS 'EMERALD CARPET'CARPET MANZANITA 1 GALLON L@ 36" O.C.
NEPETA X FAASSENII CATMINT 1' X 2'1 GALLON L99
CEANOTHUS 'CONCHA' CONCHA CEANOTHUS 6' X 8'1 GALLON L
VERBENA LILACENA 'DE LA MINA' CEDROS ISLAND VERBENA 3' X 3'1 GALLON L 83 NATCHEZ CRAPE MYRTLE 25' X 15' L15 GALLONLAGERSTROEMIA INDICA 'NATCHEZ' CHINESE ELM 30' X 30' L15 GALLON
6 SALVIA CLEVELANDII CLEVELAND SAGE 4' X 5'1 GALLON L
TROPIC BELLE MAT RUSHLOMANDRA HYSTRIX 'TROPICBELLE' 3' X 3'1 GALLON L62 18 CHONDROPETALUM ELEPHANTINUMLARGE CAPE RUSH 5' X 6'1 GALLON L 16 CHONDROPETALUM TECTORUM CAPE RUSH 3' X 4'1 GALLON L
SARATOGA LAURELLAURUS NOBILIS 'SARATOGA' 25' X 25' L15 GALLON3 8 JAPANESE MAPLE 'ARMSTRONG' 30' X 25' M15 GALLONACER RUBRUM 'ARMSTRONG'
AS NOTED
JN
ST
ST
FLOWERING CRABAPPLEMALUS 'PRAIRIFIRE' 20' X 20' M15 GALLON4
TREE SIZE
(S, M, L)
S
S
S
M
S
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
D
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\LA\PLANNING\657900CL.DWG
657900CL.DWG
L10.3
6579.00
NOV. 20, 2023
26 PLOTTED: 1/28/2025 10:52 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
PLANTING DETAILS
A
C
B
SCALE: 1" = 1'-0"
2" DEEP BASIN AROUND
ROOT BALL, TREES PLANTED
IN TURF SHALL NOT HAVE
BASINS
NATIVE GRADE
CINCH TIE
TREE
1 9
8 FOOT TAMP BASE2
BACKFILL, PUDDLE AND
SETTLE PRIOR TO PLANTING
TREE
3 AGRIFORM PLANT TABLETS,
3 PER 15 GALLON, 6 PER 24"
BOX, AND 8 FOR 36" BOX
4 TREE5
ROOT BALL6
PINE LODGE POLE STAKE, 2"
DIAMETER, PLACED ON
WINDWARD SIDES OF TREE
AND OUTSIDE OF ROOT BALL
7 NOTES:
1. SEE PLANTING SPECIFICATIONS
PRIOR TO INSTALLATION OF
PLANT MATERIALS.
2. ROOT BALL CROWN SHALL
EXTEND 1" ABOVE FINNISH
GRADE.
3. TREE INSTALLED IN TURF
AREAS SHALL BE INSTALLED
WITH 'ARBOR-GUARD' AT BASE
OF TRUNK.
2x DIAMETER
OF ROOT BALL
SECTION
2 1
3 4
5 6
7 8
6"
9 SHRUB
SCALE: 1" = 1'-0"
NOTES:
1. SEE PLANTING SPECIFICATIONS
PRIOR TO INSTALLATION OF
PLANT MATERIALS.
2. ROOT BALL CROWN SHALL
EXTEND 1" ABOVE FINNISH
GRADE.
2x DIAMETER
OF ROOT BALLSECTION
2 1
3 4
5 6
6"
NATIVE GRADE
2 3
4 SHRUB5
6 7
AGRIFORM PLANT TABLETS,
3 PER SHRUB
2" DEEP BASIN AROUND
ROOT BALL
FOOT TAMP BASE
BACKFILL, PUDDLE AND
SETTLE PRIOR TO PLANTING
SHRUB
ROOT BALL
1 7
SCALE: 1" = 1'-0"
2 1
GROUNDCOVER
EDGE OF PLANTING AREA
PLANT, SPACING VARIES, SEE
PLANTING LEGEND
1 NOTES:
1. SEE PLANTING SPECIFICATIONS PRIOR TO INSTALLATION
OF PLANT MATERIALS.
2. SPACING SHALL BE TRIANGULATED UNLESS OTHERWISE
NOTED.
3. INFILL PLANTS AS REQUIRED TO MAINTAIN SPACING AT
IRREGULAR EDGES.
2 EQUAL EQUAL
1/2 PLANT
SPACING
PLUS 6"
EQUAL
EQUAL
PLAN VIEW
SCALE: 1" = 1'-0"
MULCHED SURFACE
TREE IN STRUCTURED SOIL
1 TOP OF VERTICAL CURB3
NOTES:
1. SEE PLANTING SPECIFICATIONS
PRIOR TO INSTALLATION OF
PLANT MATERIALS.
2. ROOT BALL CROWN SHALL
EXTEND 1" ABOVE FINNISH
GRADE.
3. TREE INSTALLED IN PARKING
LOT TO RECEIVE A MINIMUM
12'X12' LOAM/SAND
STRUCTURED SOIL PROFILE
(PER SHEET SPECIFICATIONS)
AT A DEPTH OF 36" MIN.
MINIMUM 12'-0" X 12'-0" PLANTING SECTION
CONTINUOUS ALONG PAVING EDGE
3' MIN
VARIES
(SEE PLAN)
VARIES
(SEE PLAN)
1 3 4
5 6
7 8
PAVING PER PLAN4
5 OPTIONAL GEOGRID
7 STRUCTURAL SOIL
8 TREE PIT DRAINAGE TO STORM SEWER
PERFORATED PIPE (SEE CIVIL PLANS)
GEOTEXTILE FABRIC
6 2
PLANTING SOIL MIX AS SPECIFIED2
AS NOTED
JN
ST
ST
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
IC
BLOSSOM HILL ROAD
HAYES AVE
EXISTING LANDS OF SOUTHERN
PACIFIC TRANSPORTATION CO
SOUTHERN PACIFIC TRANSPORTATION COMPANY
PROPOSED
BUILDING
OFFICES
WAREHOUSE
MAINTENANCE
PARKING
PARKING
TRASH
ENCLOSURE
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\LA\PLANNING\657900CL.DWG
657900CL.DWG
L10.4
6579.00
NOV. 20, 2023
26 PLOTTED: 1/28/2025 10:52 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
HYDROZONE PLAN
IRRIGATION ZONE LEGEND:
1. FINAL DESIGN SHALL CONFORM TO AB1881 OR CITY ADOPTED WATER EFFICIENT LANDSCAPE ORDINANCE.
2. ALL PLANTING AREAS SHOWN WILL BE COMMONLY MAINTAINED BY THE OWNER AND IRRIGATED BY AN AUTOMATIC IRRIGATION SYSTEM.
3. IRRIGATION SYSTEMS WILL BE PERMANENT BELOW GROUND AUTOMATED SYSTEMS ADEQUATE FOR THE ESTABLISHMENT AND MAINTENANCE OF ALL PLANT MATERIAL.
THESE SYSTEMS WILL BE INSTALLED AS SOON AS PRACTICAL AFTER GRADING AND PRIOR TO PLANT MATERIAL INSTALLATION AND HYDROSEEDING.
4. ALL TURF, TREE, SHRUB AND GROUNDCOVER AREAS WILL BE IRRIGATED BY A PERMANENT, AUTOMATIC, UNDERGROUND IRRIGATION SYSTEM. ALL SPRAY AREAS
WILL BE IRRIGATED BY HIGH EFFICIENCY MATCHED PRECIPITATION RATE POP-UP SPRAY HEADS. TURF, TREE, SHRUB, AND GROUND COVER AREAS SHALL BE ON SEPARATE VALVES ACCORDING TO PLANT WATER REQUIREMENTS AND EXPOSURE.
5. ALL IRRIGATION SYSTEMS SHALL BE DESIGNED, MAINTAINED AND MANAGED TO MEET OR EXCEED MINIMUM EFFICIENCY.
6. ALL IRRIGATION EQUIPMENT SHALL BE SCREENED APPROPRIATELY FROM VIEW IN PUBLIC AREAS TO THE MAXIMUM EXTENT POSSIBLE.
7. THE FINAL IRRIGATION PLAN SHALL ACCURATELY AND CLEARLY IDENTIFY:
A. LOCATIONS AND SIZES OF WATER POINTS OF CONNECTION.
B. LOCATION, TYPE AND SIZE OF ALL COMPONENTS OF THE IRRIGATION SYSTEM,
INCLUDING AUTOMATIC CONTROLLERS, MAIN AND LATERAL LINES, VALVES, SPRINKLER HEADS, RAIN SWITCHES, AND QUICK COUPLERS.
C. STATIC WATER PRESSURE AT THE POINTS OF CONNECTION.
D. FLOW RATE (GALLONS PER MINUTE), REMOTE CONTROL VALVE SIZE, AND DESIGN OPERATING PRESSURE (PSI) FOR EACH STATION.
E. HYDROZONE INFORMATION TABLE.
F. WATER USE CALCULATIONS.
8. A NEW IRRIGATION WATER METER SHALL BE INSTALLED AS PART OF LANDSCAPE IMPROVEMENTS, LOCATION TO BE DETERMINED.
9. THIS PROJECT IS NOT A PART OF THE SOUTH BAY WATER RECYCLING PROGRAM. POTABLE WATER WILL BE USED FOR IRRIGATION.
LOW WATER USE AREAS FOR DRIP
AND/OR BUBBLER IRRIGATION
LOW WATER USE AREAS FOR
BIOTREATMENT IRRIGATION
IRRIGATION DESIGN CRITERIA:
PROPERTY LINE
STORMWATER TREATMENT
PLANTER, TCM 1
STORMWATER TREATMENT
PLANTER, TCM 5
PROPOSED IRRIGATION
CONTROLLER
ON-GRADE STORMWATER
TREATMENT PLANTER, TCM 7
STORMWATER TREATMENT
PLANTER, TCM 3
ON-GRADE STORMWATER
TREATMENT PLANTER, TCM 2
ON-GRADE STORMWATER
TREATMENT PLANTER, TCM 6
STORMWATER TREATMENT
PLANTER, TCM 4
NOTES:
1. SEE SHEET L10.1 FOR LANDSCAPE PLAN.
2. SEE SHEET L10.2 FOR PLANTING LEGEND, NOTES, AND TREE MITIGATION TABLE.
3. SEE SHEET L10.3 FOR PLANTING DETAILS.
4. SEE SHEET L10.4 FOR HYDROZONE PLAN.
5. SEE SHEET L10.5 FOR IRRIGATION DETAILS.
6. SEE SHEETS L10.6 - L10.7 FOR CONCEPT IMAGES.
7. SEE SHEET L10.8 FOR TREE CANOPY COVERAGE PLAN.
8. STREET TREES SHOWN CONCEPTUALLY. FINAL SELECTION TO BE COORDINATED WITH THE CITY ARBORIST.
9. STREET TREE TO BE APPROVED BY CITY ARBORIST. MAXIMUM DISTANCE FOR STREET TREES AS FOLLOWS:
20'-0" O.C. FOR SMALL STREET TREES
25'-0" O.C. FOR MEDIUM STREET TREES
35'-0" O.C. FOR LARGE STREET TREES
10.SITE TREE PLACEMENT MINIMUM DIMENSION REQUIREMENT:
5'-0" O.C. TO BUILDING STRUCTURE FOR SMALL STREET TREES 12'-0" O.C. TO BUILDING STRUCTURE FOR MEDIUM STREET TREES 20'-0" O.C. TO BUILDING STRUCTURE FOR LARGE STREET TREES
11.DESIGNATE 700 CUBIC FEET OF NON-COMPACTED SOIL FOR SMALL TREES, 1400 CUBIC FEET OF NON-COMPACTED SOIL FOR MEDIUM TREES, AND 2100 CUBIC FEET OF NON-COMPACTED SOIL FOR LARGE TREES TO ALLOW TREES TO REACH THEIR MATURITY. STRUCTURAL SOIL SYSTEMS,
SOIL CELLS, OR CONTINUOUS TRENCHES ARE EXAMPLE OF WAYS TO REACH TO THE ABOVE SOIL VOLUMES.
12.MINIMUM VERTICAL CLEARANCE FOR TREE CANOPIES AT MATURITY AS FOLLOWS:
14'-0" IN AND AROUND SERVICE AND LOADING AREAS AND DRIVEWAYS 12'-0" FOR PARKING LOTS
8'-0" FOR TREE CANOPIES IMMEDIATELY
( In Feet )
1 inch = 20 feet
GRAPHIC SCALE
80402010020
1" = 20'
JN
ST
ST
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\LA\PLANNING\657900CL.DWG
657900CL.DWG
L10.5
6579.00
NOV. 20, 2023
26 PLOTTED: 1/28/2025 10:52 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
IRRIGATION DETAILS
I ACF
BDG
H E
SCALE: N.T.S.
REMOTE CONTROL VALVE
NOTES:
1. DO NOT LOCATE REMOTE CONTROL VALVE IN LAWN
2. COMPACT SOIL AROUND BOX TO SAME DENSITY AS
ADJACENT UNDISTURBED SOIL BUNDLE AND TAPE
CONTROL WIRE TO MAINLINE EVERY 10'
3. SPLICES IN CONTROL WIRE ARE NOT ALLOWED BETWEEN
CONTROLLER AND VALVE
4. SEE IRRIGATION LEGEND FOR EQUIPMENT SPECIFICATION
5. INSTALL ALL IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS
SCOTCH LOK #3577
CONNECTOR SEALING
PACK OR EQUAL
VALVE BOX: CARSON
SPECIFICATION GRADE,
NDS PRO SERIES, OR
EQUAL
REMOTE CONTROL VALVE:
SEE IRRIG. LEGEND
PEA GRAVEL SUMP, MIN. 6"
DEEP
ID TAG FOR VALVE
STATION NUMBER
PVC SCH 80 NIPPLE
(CLOSE)
TOP OF MULCH
LATERAL LINE
18" LENGTH EXPANSION
LOOP
PVC SCH 40 MIN 8" LONG
PVC 45 FITTING SCH 40
PVC SCH 40
S X S FITTING
PVC MAINLINE PIPE
BRICK SUPPORT-1 PER
CORNER
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 9
10 11
12 13
14 8
7 6
5 31
15 42
6"
3" MIN.
SCALE: N.T.S.
GATE VALVE
BRICK SUPPORT, 2 TOTAL
VALVE BOX (CARSON 910-12B) OR EQUAL
FINISHED GRADE/ BEFORE PLANTING
GATE VALVE: SEE LEGEND FOR MAKE
AND MODEL - LINE SIZE
SCH 40 PVC MALE ADAPTOR
PVC SCH 40 MIN 8" LONG
PVC SCH 40
PVC MAINLINE PIPE
PEA GRAVEL SUMP, MIN. 6" DEEP
NOTES:
1. PLACE AGGREGATE PRIOR TO
INSTALLATION OF VALVE BOX
2. INSTALL VALVE BOX SO TOP OF BOX IS
FLUSH WITH ADJACENT HARDSCAPE
PVC 45 FITTING SCH 40 (TYP.)
18" MIN.
10" MIN.
1 2
3 4
5 6
7 8
9 10
1 2
10 9
8 7
6 5
4 36"
SCALE: N.T.S.
NOTES:
1. NIPPLES AND FITTINGS TO BE SAME IPT
SIZE AS BACKFLOW ASSEMBLY.
2. INSTALL GREEN WEATHER GUARD
BACKFLOW BLANKET OR APPROVED
EQUAL.
3. DISSIMILAR METALS SHALL BE
SEPARATED BY AN APPROVED
DIELECTRIC FITTING.
4. ENCLOSURE SHALL BE STRONG BOX
LOW PROFILE SMOOTH TOUCH
SBBC-30CR OR SBBC-45CR, COLOR
DARK GREEN OR APPROVED EQUAL.
ENCLOSURE SHALL BE SIZED BASED
ON BACKFLOW DEVICE SIZE. CONTACT
MANUFACTUER V.I.T. PRODUCTS
1-800-729-1314.
SCH. 80 PVC COUPLING- 2 TOTAL
SCH. 80 PVC 90° ELBOW-2 TOTAL (TxT
CONNECTION)
PVC MAIN LINE TO POINT OF CONNECTION
BUSH AS NECESSARY FOR SIZE TRANSITION
PVC MAIN LINE TO IRRIGATION SYSTEM
SCH. 80 PVC NIPPLE-2 TOTAL
FINISHED GRADE
POURED CONCRETE BASE-6" MIN.
THICKNESS-EXTEND 4" BEYOND OUTSIDE
DIMENSIONS OF ENCLOSURE
CONCRETE SUPPORT BLOCK
SCH. 80 PVC MALE ADAPTER-2 TOTAL
SCH.40 GALVANIZED STEEL NIPPLES-2 TOTAL
REDUCED PRESSURE BACKFLOW DEVICE
ENCLOSURE AND BLANKET
BACKFLOW ENCLOSURE-SEE NOTE 4.
ANCHOR ROD (TYPICAL)
ENCLOSURE
2 3
4 5
6 7
8 10 9
14 15
9 10
11 12
13 14
13 REDUCED PRESSURE BACKFLOW ASSEMBLY
PER IRRIGATION LEGEND1
BACKFLOW BLANKET15
1 FLOW
SEE
IRRIGATION
LEGEND
BACKFLOW DEVICE
13 2
3 4
8 126
10 9
5 7
1 15
11 8"
MIN.
PER
CODE
SCALE: N.T.S.
QUICK COUPLING VALVE
10" ROUND PLASTIC VALVE
BOX WITH BOLT DOWN LID
1 1/4" x 1 1/4" x 3/16" ANGLE
IRON 30" LONG, 2 STAINLESS
STEEL STRAPS
3" LONG SCHEDULE 80 PVC
THREADED NIPPLE
NOTE:
1. NIPPLES AND FITTINGS
TO BE SAME SIZE AS
VALVE IPT INLET
THREAD SIZE
2. SEE IRRIGATION
LEGEND FOR
SPECIFICATION
3. INSTALL ALL IN
ACCORDANCE WITH
MANUFACTURER'S
RECOMMENDATIONS
10" LONG SCH 80 PVC
THREADED NIPPLE
SCH 80 PVC THREADED 90
DEGREE ELL
QUICK COUPLING VALVE
FINISHED GRADE
SEE
IRRIGATION
LEGEND
SIDE VIEW
TOP VIEW
1 114
10 2 9
5 1
2 3
PEA GRAVEL SUMP, MIN. 6"
DEPTH
3 4
5 6
MAINLINE FITTING7
7 9
10 11
2" MAX.
5 11
12 BRICK SUPPORTS, 2 TOTAL12
PVC MAINLINE6
DRIPLINE CENTER - FEED LAYOUT
SCALE: N.T.S.
FV
AV
FV
DRIPLINE AUTOMATIC FLUSH
VALVE PLUMBED TO FLUSH
MANIFOLD AT LOW POINT
PVC FLUSH MANIFOLD
DRIPLINE MANIFOLD-TO-ELBOW
CONNECTION
REMOTE CONTROL VALVE WITH
FILTER AND PRESSURE REGULATOR
PVC SUPPLY MANIFOLD
DRIPLINE MANIFOLD-TO-TEE
CONNECTION
DRIPLINE LATERAL
AIR/VACUUM RELIEF LATERAL
DRIPLINE BLANK TUBING
CENTERED ON MOUND OR BERM
DRIPLINE AIR / VACUUM RELIEF
VALVE PLUMBED TO DRIPLINE BLANK
TUBING AT EACH HIGH POINT
PERIMETER LATERALS 2" TO 4"
FROM EDGE
ZONE PERIMETER
DRIPLINE OPERATION INDICATOR
NOTE:
1. SEE IRRIGATION LEGEND FOR EQUIPMENT SPECIFICATION
2. INSTALL ALL IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS
3. THE TOTAL LENGTH OF ALL INTERCONNECTED DRIP LINE
SHALL NOT EXCEED THE MAXIMUM RUN LENGTH
PLAN
1 2
3 4
5 6
7 8
9 10
11 12
1 2
3 7
4 9
10 11
12 8
5 6
SCALE: N.T.S.
NOTES:
1. BUBBLER DISTANCE TO ROOT
BALL WILL VARY DEPENDING ON
THE CONTAINER SIZE OF THE
PLANT. ALLOW 6" BETWEEN
TRUNK AND BUBBLER.
2. PLACE ALL BUBBLERS ON
UPHILL SIDE OF SLOPE IF
APPLICABLE. CONCEAL ALL
EQUIPMENT UNDER MULCH.
3. SEE IRRIGATION LEGEND FOR
SPECIFICATION.
4. INSTALL ALL IN ACCORDANCE
WITH MANUFACTURER'S
RECOMMENDATIONS.
FINISHED GRADE
TUBING STAKES PVC
COATED 12 GAUGE WIRE
U STAKES QUANTITY AS
NEEDED TO SECURE
TUBING (2 MIN.) SALCO
OR EQUAL
MULCH PER
SPECIFICATIONS
POSITION BUBBLER
OVER ROOT BALL
PRESSURE
COMPENSATING DRIP
BUBBLER (SEE LEGEND
FOR MODEL)
SUPER FUNNY PIPE
850-35 ADAPTER
PVC LATERAL PIPE
PVC SCH 40 TEE OR ELL
1/2" (SLIP XSLIP X FIPT)
1/2" PVC SCH 40 (MIPT X
SLIP) MALE ADAPTER UV
RADIATION RESISTANT
ROOT BALL
PLANT CROWN
SUPER FUNNY PIPE 850
SOIL RING (SEE
PLANTING DETAILS)
ON GRADE TREE BUBBLER
1 2
3 4
5 6
7 8
9 10
11 12
13 1 2
3 4
5 6
7 8
9 10
13 12
11 3
SCALE: N.T.S.
24 VOLT CONTROL WIRING
FINISHED GRADE
PEDESTAL MOUNT CONTROLLER
2-1" PVC CONDUITS FOR 120
VOLT A.C. AND SIGNAL WIRE
CONCRETE PAD-6" THICK (MIN.)
EXTEND 6" BEYOND EACH SIDE
AND BACK AND 24" IN FRONT
PLASTIC VALVE BOX SEE
SPECIFICATIONS FOR TYPE
8' LONG COPPER GROUND ROD
4" PVC SWEEP ELL ROUND
IRRIGATION CONTROLLER-SEE
IRRIGATION LEGEND FOR
SPECIFICATION
GROUND WIRE
24"
11 2"
NOTE:
1. VERIFY POWER SOURCE WITH PROJECT
ELECTRICIAN.
2. ALL ELECTRICAL WORK MUST CONFORM TO
LOCAL CODES. REFER TO PRODUCT
LITERATURE FOR ADDITIONAL INSTALLATION
REQUIREMENTS. THIS DRAWING IS PROVIDED
FOR REFERENCE ONLY. INDIVIDUAL PROJECT
REQUIREMENTS AND LOCAL CODES MAY
DICTATE DIFFERENCES IN INSTALLATION
PROCEDURES THAT ARE NOT IDENTIFIED ON
THIS DETAIL.
1 2
3 4
5 6
7 8
9 3
4 6
5 8
92 1
7 PVC SCH 80 NIPPLE (LENGTH AS
REQUIRED)
PVC SCH 80 NIPPLE (LENGTH AS
REQUIRED)
POP-UP SPRAY SPRINKLER: SEE
LEGEND FOR MAKE, MODEL AND
NOZZLE TYPE
NOTE:
1. ALWAYS INSTALL SPRAY SPRINKLER
PERPENDICULAR TO FINISHED GRADE.
2. SEE IRRIGATION LEGEND FOR
EQUIPMENT SPECIFICATION.
3. INSTALL ALL IN ACCORDANCE WITH
MANUFACTURER'S RECOMMENDATIONS.
POP UP SPRINKLER
SCALE: N.T.S.
1/2" ABOVE FINISHED GRADE
FINISHED GRADE/TOP OF MULCH
MARLEX STREET ELL
PVC SCH 40 TEE OR ELL
PVC LATERAL PIPE
2"
1 2
3 4
5 6
7 8
1 2
3 4
7 5
6 5
7 8
2" FROM EDGE OF HARDSCAPE
MINIMUM
9 9
N.T.S.
MASTER VALVE
NOTES:
1. DO NOT LOCATE REMOTE VALVE IN TURF
2. COMPACT SOIL AROUND BOX TO SAME DENSITY AS
ADJACENT UNDISTURBED SOIL BUNDLE AND TAPE
CONTROL WIRE TO MAINLINE EVERY 10'
3. SPLICES IN CONTROL WIRE ARE NOT ALLOWED
BETWEEN CONTROLLER AND VALVE
4. SEE IRRIGATION LEGEND FOR EQUIPMENT
SPECIFICATION
5. INSTALL ALL IN ACCORDANCE WITH MANUFACTURER'S
RECOMMENDATIONS
1 MASTER VALVE-SEE LEGEND1
CARSON #1324 RECTANGULAR
VALVE BOX WITH BLACK BOLT
DOWN COVER, OR APPROVED
EQUAL. HEAT BRAND "MV" ON LID
IN 2" HIGH LETTERS
2 FINISHED GRADE3
FROM POINT OF CONNECTION-
ADAPT AS REQUIRED4
SCH. 80 TOE NIPPLE- LENGTH
AS REQUIRED5
PEA GRAVEL SUMP, MIN 6" DEEP6
3M DBY WIRE CONNECTOR7
CONTROL AND COMMON WIRE TO
DESIGNATED AUTOMATIC
CONTROLLER
8 FLOW SENSOR CABLE WITHIN
CONDUIT9
BRICK SUPPORT, 1 PER
CORNER10
6"
6"
23 4
5 6
7 8
9 10
TO FLOW
SENSOR
AS NOTED
JN
ST
ST
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\LA\PLANNING\657900CL.DWG
657900CL.DWG
L10.6
6579.00
NOV. 20, 2023
26 PLOTTED: 1/28/2025 10:53 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
CONCEPT IMAGES
TREES
SHRUBS AND GROUNDCOVERS
BIO TREATMENT SHRUBS
DWARF MAT RUSH
LOMANDRA LONGIFOLIA 'BREEZE' ERIGERON KARVINSKIANUS
SANTA BARBARA DAISY
ULMUS PARVIFOLIA
JUNCUS PATENS
COMMON RUSH
ARCTOSTAPHYLOS 'EMERALD CARPET'
CARPET MANZANITA
NEPETA X FAASSENII
CATMINT
CEANOTHUS 'CONCHA'
CONCHA CEANOTHUS
VERBENA LILACENA 'DE LA MINA'
CEDROS ISLAND VERBENA
NATCHEZ CRAPE MYRTLE
LAGERSTROEMIA INDICA 'NATCHEZ'
CHINESE ELM
SALVIA CLEVELANDII
CLEVELAND SAGETROPIC BELLE MAT RUSH
LOMANDRA HYSTRIX 'TROPICBELLE' CHONDROPETALUM ELEPHANTINUM
LARGE CAPE RUSH
SARATOGA LAUREL
LAURUS NOBILIS 'SARATOGA'
CHONDROPETALUM TECTORUM
CAPE RUSH
JAPANESE MAPLE 'ARMSTRONG'
ACER RUBRUM 'ARMSTRONG'
AS NOTED
JN
ST
ST
MALUS 'PRAIRIFIRE'
FLOWERING CRABAPPLE
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\LA\PLANNING\657900CL.DWG
657900CL.DWG
L10.7
6579.00
NOV. 20, 2023
26 PLOTTED: 1/28/2025 10:53 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
CONCEPT IMAGES
BIKE RACK
AS NOTED
JN
ST
ST
BIKE LOCKER
CAPITOL BIKE RACK BY FORMS+SURFACES
MODEL NUMBER: SKCAP
BIKE LOCKER SINGLE (D1) BY DERO
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
IC
194'
111'
115'
147'
37'
77'
BLOSSOM HILL ROAD
HAYES AVE
EXISTING LANDS OF SOUTHERN
PACIFIC TRANSPORTATION CO
SOUTHERN PACIFIC TRANSPORTATION COMPANY
PROPOSED
BUILDING
OFFICES
WAREHOUSE
MAINTENANCE
PARKING
PARKING
TRASH
ENCLOSURE
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMH C
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\LA\PLANNING\657900CL.DWG
657900CL.DWG
L10.8
6579.00
NOV. 20, 2023
26 PLOTTED: 1/28/2025 10:53 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/ /2024 PLANNING PC COMMENT
RESPONSE3
TREE CANOPY
COVERAGE PLAN
NOTES:
1. SEE SHEET L10.1 FOR LANDSCAPE PLAN.
2. SEE SHEET L10.2 FOR PLANTING LEGEND, NOTES, AND TREE MITIGATION TABLE.
3. SEE SHEET L10.3 FOR PLANTING DETAILS.
4. SEE SHEET L10.4 FOR HYDROZONE PLAN.
5. SEE SHEET L10.5 FOR IRRIGATION DETAILS.
6. SEE SHEETS L10.6 - L10.7 FOR CONCEPT IMAGES.
7. SEE SHEET L10.8 FOR TREE CANOPY COVERAGE PLAN.
8. STREET TREES SHOWN CONCEPTUALLY. FINAL SELECTION TO BE COORDINATED WITH THE CITY ARBORIST.
9. STREET TREE TO BE APPROVED BY CITY ARBORIST. MAXIMUM DISTANCE FOR STREET TREES AS FOLLOWS:
20'-0" O.C. FOR SMALL STREET TREES
25'-0" O.C. FOR MEDIUM STREET TREES
35'-0" O.C. FOR LARGE STREET TREES
10.SITE TREE PLACEMENT MINIMUM DIMENSION REQUIREMENT:
5'-0" O.C. TO BUILDING STRUCTURE FOR SMALL STREET TREES 12'-0" O.C. TO BUILDING STRUCTURE FOR MEDIUM STREET TREES 20'-0" O.C. TO BUILDING STRUCTURE FOR LARGE STREET TREES
11.DESIGNATE 700 CUBIC FEET OF NON-COMPACTED SOIL FOR SMALL TREES, 1400 CUBIC FEET OF NON-COMPACTED SOIL FOR MEDIUM TREES, AND 2100 CUBIC FEET OF NON-COMPACTED SOIL FOR LARGE TREES TO ALLOW TREES TO REACH THEIR MATURITY. STRUCTURAL SOIL SYSTEMS,
SOIL CELLS, OR CONTINUOUS TRENCHES ARE EXAMPLE OF WAYS TO REACH TO THE ABOVE SOIL VOLUMES.
12.MINIMUM VERTICAL CLEARANCE FOR TREE CANOPIES AT MATURITY AS FOLLOWS:
14'-0" IN AND AROUND SERVICE AND LOADING AREAS AND DRIVEWAYS 12'-0" FOR PARKING LOTS
8'-0" FOR TREE CANOPIES IMMEDIATELY
PROPOSED TREE CANOPY SHADE CALCULATION TABLE
SYMBOL BOTANICAL NAME /
COMMON NAME
QUANTITY @ 100%
SHADE / SQ. FT.
QUANTITY @ 75%
SHADE / SQ. FT.
QUANTITY @ 50%
SHADE / SQ. FT.TOTAL (SQ. FT.)
GENERAL LOCATION OF
QUALIFYING TREES
TOTAL TREE SHADE = 4,551
SURFACED AREA: PARKING LOT TOTAL SURFACE AREA = 24,395
12,197
4,551
SHADE AREA TARGET =
TOTAL SHADE PROVIDED =
18.6%PERCENT SHADE =
24,395
- -
3 @ 353 1,059- -
- -
- - - -
- - - -
*TREE PLACEMENT AND HEIGHT HAS BEEN COORDINATED WITH PG&E, TAKING INTO CONSIDERATION THE REQUIREMENTS
AND RECOMMENDATIONS MADE AS RELATED TO SAFETY, OPERATIONS AND MAINTENANCE
LAURUS NOBILIS 'SARATOGA'/
SARATOGA LAUREL
ULMUS PARVIFOLIA/
CHINESE ELM
LAGERSTOEMIA 'NATCHEZ'
CRAPE MYRTLE
- 11 @ 246 2,706
2,543
100%
( In Feet )
1 inch = 20 feet
GRAPHIC SCALE
80402010020
ACER RUBRUM 'ARMSTRONG'
JAPANESE MAPLE 'ARMSTRONG'
1" = 20'
JN
ST
ST
MALUS 'PRAIRIFIRE'/
FLOWERING CRABAPPLE
- 2 @ 236 2 @ 157 786
-
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\LA\PLANNING\657900CL.DWG
657900CL.DWG
L10.9
6579.00
NOV. 20, 2023
27 PLOTTED: 2/4/2025 9:12 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
FENCE AND GATE
DETAILS
AS NOTED
JN
ST
ST
A METAL FENCE
B PEDESTRIAN METAL GATE
C VEHICULAR SWING METAL GATE
NOTES:
1. SHALL BE METAL.
2. SHALL BE COLOR BLACK.
NOTES:
1. SHALL BE METAL.
2. SHALL BE COLOR BLACK.
6'-0"
NOTES:
1. SHALL BE METAL.
2. SHALL BE COLOR BLACK.
6'-0"
6'-0"
CONCEPT IMAGES
METAL FENCEPEDESTRIAN GATE VEHICULAR SWING GATE
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
1.2 1.5
1.6 1.6
1.7 1.8
2.1 2.6
3.5 4.5
5.2 4.8
4.1 2.4
2.9 2.8
2.3 1.8
1.5 1.3
1.2 1.2
1.3 1.4
1.4 1.3
1.1 1.7
2.0 2.0
1.9 1.9
2.0 2.3
2.9 3.8
5.0 5.8
5.3 4.3
2.2 2.7
3.0 2.5
2.0 1.6
1.4 1.4
1.4 1.5
1.6 1.8
1.8 1.5
0.6 2.3
2.6 2.5
2.3 2.2
2.2 2.5
3.1 4.0
5.2 6.1
5.6 4.6
2.3 2.8
3.1 2.6
2.0 1.7
1.5 1.5
1.6 1.7
1.9 2.2
2.4 2.1
0.8 2.7
2.9 2.7
2.5 2.3
2.4 2.6
3.1 4.0
5.2 6.0
5.6 4.8
3.0 3.4
3.3 2.7
2.1 1.7
1.6 1.6
1.7 1.9
2.2 2.5
2.8 2.6
1.0 2.7
2.9 2.8
2.6 2.4
2.4 2.6
3.1 4.0
5.1 6.0
5.9 5.1
4.0 4.0
3.4 2.6
2.1 1.7
1.6 1.6
1.7 2.0
2.3 2.6
2.7 2.6
1.0 3.0
3.1 3.0
2.7 2.2
2.0 2.1
2.3 2.8
4.8 5.8
6.0 5.3
5.7 4.9
3.6 2.6
2.0 1.7
1.6 1.6
1.7 2.0
2.4 2.8
2.9 2.9
3.5 3.5
3.2 2.8
2.2 2.0
2.0 2.1
2.3 2.7
5.4 5.5
4.8 8.1
6.2 3.8
2.6 2.0
1.8 1.7
1.7 1.8
2.1 2.5
3.0 3.3
3.3 3.8
3.4 3.2
2.8 2.2
2.0 1.9
1.9 4.1
3.6 7.6
5.9 3.7
2.6 2.1
1.8 1.7
1.8 1.9
2.1 2.6
3.0 3.3
3.8 3.4
3.4 3.2
2.8 2.2
1.9 1.8
1.1 3.4
3.1 6.0
5.0 3.8
2.7 2.1
1.9 1.8
1.8 2.0
2.2 2.6
3.1 3.4
3.4 3.0
3.1 2.9
2.6 2.2
1.9 1.5
1.2 3.4
2.9 7.1
7.0 4.2
2.8 2.2
2.0 1.9
1.9 2.1
2.3 2.6
2.9 3.0
2.8 2.9
2.8 2.7
2.2 2.0
1.9 1.8
1.9 2.2
4.8 5.6
5.7 3.2
3.2 3.8
4.8 5.1
4.6 4.4
4.8 5.2
4.6 4.1
4.6 6.6
10.0 12.7
14.2 12.4
11.6 13.3
12.6 7.9
4.5 3.0
2.4 2.2
2.1 2.1
2.2 2.4
2.6 2.7
2.7 3.0
2.8 2.6
2.5 2.4
2.5 2.7
3.1 3.8
4.8 5.6
5.8 3.9
3.9 4.5
5.3 5.5
5.1 4.9
5.3 5.6
5.1 4.6
4.9 6.0
7.7 9.1
9.9 10.0
8.9 8.5
9.1 8.5
5.8 3.8
2.8 2.5
2.3 2.3
2.4 2.4
2.5 2.6
2.7 2.3
2.7 2.6
2.5 2.4
2.5 2.5
2.7 3.0
3.5 4.3
4.7 5.0
3.8 4.1
4.4 4.7
4.9 4.9
4.9 5.0
5.0 4.8
4.5 4.5
4.6 5.0
5.4 5.6
5.5 5.1
5.0 4.9
4.7 3.8
3.0 2.7
2.5 2.5
2.5 2.6
2.6 2.5
2.5 2.1
2.3 2.3
2.3 2.4
2.6 2.7
2.9 3.1
3.6 3.9
4.0 3.2
3.3 3.5
3.7 3.8
3.8 3.8
3.9 3.8
3.7 3.5
3.4 3.3
3.4 3.4
3.3 3.3
3.1 3.0
3.0 3.0
2.7 2.6
2.5 2.6
2.7 2.8
2.8 2.7
2.4 1.9
2.2 2.3
2.5 2.6
2.7 2.8
2.9 3.1
3.2 3.2
2.5 2.6
2.7 2.8
2.8 2.8
2.8 2.8
2.8 2.7
2.6 2.5
2.4 2.4
2.3 2.3
2.3 2.2
2.2 2.2
2.3 2.3
2.4 2.5
2.7 2.9
3.1 3.1
2.8 2.3
2.0 2.3
2.5 2.7
2.7 2.7
2.8 2.7
2.6 2.6
2.0 2.1
2.1 2.1
2.1 2.1
2.1 2.0
2.0 2.0
1.9 1.9
1.9 1.8
1.8 1.8
1.8 1.8
1.8 1.9
2.0 2.2
2.3 2.6
2.9 3.1
3.3 3.4
2.8 1.7
2.3 2.7
2.9 2.9
2.8 2.7
2.5 2.3
2.2 1.8
1.7 1.7
1.7 1.6
1.6 1.6
1.5 1.5
1.5 1.5
1.5 1.5
1.5 1.6
1.6 1.6
1.6 1.7
1.8 2.0
2.2 2.5
2.8 3.1
3.2 3.3
3.3 2.3
3.0 3.2
3.0 2.9
2.6 2.4
2.2 2.0
1.6 1.5
1.5 1.4
1.4 1.3
1.3 1.3
1.2 1.2
1.3 1.3
1.3 1.4
1.5 1.6
1.6 1.7
1.7 1.9
2.1 2.3
2.6 3.1
3.4 3.4
3.2 3.0
3.3 3.1
3.0 2.8
2.4 2.2
2.0 1.6
1.5 1.4
1.3 1.2
1.2 1.1
1.1 1.1
1.1 1.1
1.2 1.3
1.4 1.5
1.6 1.7
1.8 1.9
2.0 2.3
2.6 3.0
3.3 3.6
3.7 3.2
3.2 3.2
3.0 2.6
2.3 2.0
1.7 1.5
1.3 1.3
1.2 1.1
1.1 1.1
1.0 1.1
1.1 1.2
1.3 1.4
1.5 1.7
1.8 2.0
2.1 2.2
2.5 2.8
3.2 3.5
3.7 3.9
3.0 3.5
3.6 3.3
2.9 2.4
2.1 1.7
1.6 1.4
1.3 1.2
1.2 1.1
1.1 1.1
1.1 1.1
1.2 1.3
1.4 1.6
1.8 1.9
2.1 2.3
2.5 2.7
2.9 3.1
3.3 3.5
3.8 3.7
3.5 3.2
2.7 2.3
1.9 1.7
1.5 1.4
1.3 1.3
1.2 1.1
1.1 1.1
1.1 1.2
1.3 1.5
1.6 1.8
2.0 2.2
2.4 2.6
2.9 3.1
3.1 3.1
3.9 3.7
3.3 2.9
2.5 2.1
1.9 1.7
1.6 1.5
1.4 1.3
1.2 1.2
1.2 1.2
1.3 1.4
1.5 1.7
1.9 2.1
2.3 2.5
2.7 3.0
3.3 3.2
3.4 3.2
3.0 2.7
2.3 2.1
1.8 1.7
1.6 1.5
1.4 1.3
1.3 1.3
1.3 1.4
1.4 1.6
1.7 2.0
2.2 2.4
2.5 2.7
2.9 2.9
2.6 3.2
3.4 3.2
2.9 2.4
2.1 1.9
1.8 1.7
1.6 1.5
1.4 1.4
1.4 1.4
1.5 1.5
1.6 1.8
2.1 2.3
2.4 2.5
2.6 2.6
2.3 3.4
3.3 2.9
2.5 2.2
2.0 1.8
1.7 1.7
1.6 1.6
1.6 1.5
1.6 1.6
1.7 1.8
2.0 2.2
2.4 2.5
2.6 2.5
2.3 2.7
2.9 2.7
2.4 2.2
2.0 1.9
1.8 1.8
1.7 1.7
1.7 1.7
1.8 1.8
1.9 2.0
2.2 2.4
2.6 2.7
2.7 2.5
2.3 2.3
2.2 2.1
2.0 1.9
1.9 1.8
1.9 1.9
2.0 2.0
2.0 2.1
2.2 2.3
2.5 2.7
2.8 2.8
2.9 1.9
2.1 2.0
2.0 2.0
1.9 1.9
2.0 2.0
2.1 2.2
2.3 2.3
2.4 2.6
2.8 3.0
3.1 3.0
2.9 1.6
1.9 2.0
2.0 2.0
2.0 2.0
2.1 2.2
2.4 2.5
2.6 2.7
2.8 2.9
3.2 3.3
3.5 3.2
1.9 2.1
2.1 2.1
2.2 2.2
2.3 2.4
2.6 2.7
2.8 3.0
3.0 3.2
3.4 3.6
3.7 2.2
2.3 2.4
2.4 2.5
2.5 2.6
2.7 2.8
2.9 3.0
3.2 3.3
3.2 3.3
2.6 2.8
2.9 3.0
2.9 2.9
3.0 3.0
3.1 3.2
3.4 3.5
2.8 3.2
3.2 3.3
3.2 3.1
3.1 3.2
3.1 3.0
3.4 3.5
3.5 3.2
3.1 0.4
14.6 R1 @ 11'
R1 @ 11'
R1 @ 11'
R1 @ 11'
R1 @ 11'
R1 @ 11'
S1 @ 12'
S1 @ 10' S1 @ 10' S1 @ 10'
S1 @ 16'
S1 @ 16'
S1 @ 16'
A @ 21'
A @ 21'
A @ 21'
A @ 21'
A @ 21'
A @ 21'
Statistics
Description Symbol
Calc Zone #1
Schedule
Symbol Label Image Quantity Manufacturer
R1
6 PRISMA LIGHTING
S1
7 INVUE LIGHTING
A
6 MCGRAW- EDISON
LIGHTING
BLOSSOM HILL ROAD
HAYES AVE
PROPOSED
BUILDING
PARKING
TRASH
ENCLOSURE
Statistics
Description Symbol Avg Max Min Max/Min Avg/Min
Calc Zone #1 2.8 fc 14.6 fc 0.4 fc 36.5:1 7.0:1
Schedule
Symbol Label Image Quantity Manufacturer Catalog Number Description Number Lamps
Lumens
Per Lamp
Light Loss
Factor Wattage
R1
6 PRISMA LIGHTING 071453 BLIZ ROUND 40 40W 830 S/EW 0-10V Iron gray
1 2739 0.9 40
S1
7 INVUE LIGHTING CCW-VA-4-727-U-T4W INVUE WALL PACK Wave Stream LUMINAIRE WITH T4W DISTRIBUTION
LENS
1 5789 0.9 57.6
A
6 MCGRAW- EDISON
LIGHTING
GALN-SA2C-727-U-SL4-
HSS
GALLEON AREA AND ROADWAY LUMINAIRE
(2) 70 CRI, 2700K, 1050mA
LIGHTSQUARES WITH 16 LEDS EACH AND
TYPE IV SPILL LIGHT ELIMINATOR OPTICS
WITH HOUSE SIDE SHIELD
32 304 0.9 108
DRAWN BY:
PROJECT NO:
CAD DWG FILE:
CHECKED BY:
DESIGNED BY:
DATE:
SCALE:
HMHC
DATE DESCRIPTIONNO
15 COTTLE ROAD
15 COTTLE ROAD SAN JOSE
CONDITIONAL USE PERMIT
CP24-001
S:\PROJECTS\657900\LA\PLANNING\657900CL.DWG
657900CL.DWG
P1
6579.00
NOV. 20, 2023
27 PLOTTED: 2/4/2025 9:13 AMOF
Land Use Entitlements
Land Planning
Landscape Architecture
Civil Engineering
Utility Design
Land Surveying
Stormwater Compliance
1570 Oakland Road (408) 487-2200
San Jose, CA 95131 HMHca.com
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
SITE
PHOTOMETRICS
NTS
JN
ST
ST
SITE LIGHTING REQUIREMENTS
ORIENT ALL SITE LIGHTING DIRECTLY DOWNWARDS TO PREVENT LIGHT POLLUTION AND EXCESS GLARE IN THE PUBLIC REALM.
ILLUMINATE A ZONE OF A MAXIMUM OF FIVE FEET IN FRONT OF THE GROUND FLOOR FACADE FOR ALL ACTIVE FRONTAGES SUCH AS RETAIL, OFFICES, AND COMMUNITY ROOMS.
AT LEAST ONE PEDESTRIAN AND BICYCLE CIRCULATION ROUTE MUST HAVE AN UNBROKEN LINE OF LIGHTING FROM SITE ENTRANCE TO THE BUILDING ENTRANCE.
FULLY ILLUMINATE ALL SERVICE YARDS AND ACCESS TO SERVICES AND UTILITIES.
ALL SITE LIGHTING FIXTURES MUST BE FULLY SHIELDED (FULL CUT-OFF) TO PREVENT LIGHT FROM AIMING SKYWARD AND LIGHT SPILLAGE AND GLARE THAT CAN BE SEEN FROM ABOVE.
KEEP THE MAXIMUM COLOR TEMPERATURE FOR OUTDOOR LIGHTING BELOW 2700 KELVIN, EXCEPT FOR OUTDOOR DECORATIVE LIGHTING FROM NOVEMBER 15 TO JANUARY 15.
WHEN ADJACENT TO A RESIDENTIAL DEVELOPMENT, LIGHTING FIXTURES FOR COMMERCIAL, INDUSTRIAL, OR QUASI-PUBLIC DEVELOPMENTS MUST BE LESS THAN 40-FEET TALL, IRRESPECTIVE OF THE DISTANCE FROM THE COMMON PROPERTY LINE.
A - MCGRAW - EDISON GALLEON AREA
AND ROADWAY LUMINAIRE
S1 - INVUE WALL MOUNT
SHALL BE 10', 12', or 16' TALL
SEE LOCATIONS ON PLAN
SHALL BE 21' TALL
25'-6"
( In Feet )
1 inch = 20 feet
GRAPHIC SCALE
80402010020
R1 - PRISMA LIGHTING
SHALL BE 11' TALL
53'-2"
53'-1"
20'-0"
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
DATE DESCRIPTIONNO
3/15/20241
6/21/2024 PLANNING PC COMMENT
RESPONSE2
PER CITY COMMENTS
10/11/2024 PLANNING PC COMMENT
RESPONSE3
1/28/2025 PLANNING PC COMMENT
RESPONSE4
28 Exhibit E - Project Plans
15 COTTLE ROAD – REZONING AND
CONDITIONAL USE PERMIT
ENVIRONMENTAL NOISE ASSESSMENT
San José, California
June 19, 2024
Prepared for:
Olivia Bergin
Assistant Planner
HMH
1570 Oakland Road
San José, CA 95131
Prepared by:
Micah Black
Michael S. Thill
429 East Cotati Avenue
Cotati, CA 94931
(707) 794-0400
I&R Job No.: 23-177
Exhibit F - Noise Report
1 INTRODUCTION
The project proposes the demolition of an existing 1,638-square-foot retail building, construction of a new 5,000-square-foot construction equipment sales building, and the reconfiguration of the site layout and locations of on-site noise-generating operations at 15 Cottle Road in the City of San José, California. Operations at the 0.94 -acre site will be comparable to previous conditions.
The same number of employees, customers, parking spaces, and deliveries are expected. The new building will be larger than the previous building and will be located closer to the western property line of the site, which will aid in reducing transportation noise levels and operational noise levels at the adjoining residential properties by acting as a noise barrier.
This report assesses the potential for the project to generate a substantial permanent increase in ambient noise levels at residential receptors in the project vicinity. The report is divided into two sections: 1) the Setting Section provides a brief description of the fundamentals of environmental noise, summarizes applicable regulatory criteria, and discusses ambient noise conditions in the project vicinity; and 2) the Impacts and Mitigation Measures Section describes the significance criteria used to evaluate project impacts and presents mitigation measures, where necessary, to mitigate project impacts to less-than-significant levels.
SETTING
Fundamentals of Environmental Noise
Noise may be defined as unwanted sound. Noise is usually objectionable because it is disturbing or annoying. The objectionable nature of sound could be caused by its pitch or its loudness. Pitch is the height or depth of a tone or sound, depending on the relative rapidity ( frequency) of the vibrations by which it is produced. Higher pitched signals sound louder to humans than sounds with a lower pitch. Loudness is the intensity of sound waves combined with the reception characteristics of the ear. Intensity may be compared with the height of an ocean wave in that it is a measure of the amplitude of the sound wave.
In addition to the concepts of pitch and loudness, there are several noise measurement scales which are used to describe noise in a particular location. A decibel (dB) is a unit of measurement which indicates the relative amplitude of a sound. The zero on the decibel scale is based on the lowest sound level that the healthy, unimpaired human ear can detect. Sound levels in decibels are calculated on a logarithmic basis. An increase of 10 decibels represents a ten -fold increase in acoustic energy, while 20 decibels is 100 times more intense, 30 decibels is 1,000 times more intense, etc. There is a relationship between the subjective noisiness or loudness of a sound and its intensity. Each 10 decibel increase in sound level is perceived as approximately a doubling of loudness over a fairly wide range of intensities. Technical terms are defined in Table 1.
There are several methods of characterizing sound. The most common in California is the A- weighted sound level (dBA). This scale gives greater weight to the frequencies of sound to which the human ear is most sensitive. Representative outdoor and indoor noise levels in units of dBA are shown in Table 2. Because sound levels can vary markedly over a short period of time, a method for describing either the average character of the sound or the statistical behavior of the Exhibit F - Noise Report
2 variations must be utilized. Most commonly, environmental sounds are described in terms of an average level that has the same acoustical energy as the summation of all the time-varying events.
This energy-equivalent sound/noise descriptor is called Leq. The most common averaging period is hourly, but Leq can describe any series of noise events of arbitrary duration.
The scientific instrument used to measure noise is the sound level meter. Sound level meters can accurately measure environmental noise levels to within plus or minus 1 dBA. Various computer models are used to predict environmental noise levels from sources, such as roadways and airports.
The accuracy of the predicted models depends upon the distance the receptor is from the noise source. Close to the noise source, the models are accurate to within about plus or minus 1 to 2 dBA.
Since the sensitivity to noise increases during the evening and at night -- because excessive noise interferes with the ability to sleep -- 24-hour descriptors have been developed that incorporate artificial noise penalties added to quiet-time noise events. The Community Noise Equivalent Level (CNEL) is a measure of the cumulative noise exposure in a community, with a 5 dB penalty added to evening (7:00 pm - 10:00 pm) and a 10 dB addition to nocturnal (10:00 pm - 7:00 am) noise levels. The Day/Night Average Sound Level (DNL or Ldn) is essentially the same as CNEL, with the exception that the evening time period is dropped and all occurrences during this three -hour period are grouped into the daytime period.
Effects of Noise
Sleep and Speech Interference
The thresholds for speech interference indoors are about 45 dBA if the noise is steady and above 55 dBA if the noise is fluctuating. Outdoors the thresholds are about 15 dBA higher. Steady noises of sufficient intensity (above 35 dBA) and fluctuating noise levels above about 45 dBA have been shown to affect sleep. Interior residential standards for multi-family dwellings are set by the State of California at 45 dBA DNL. Typically, the highest steady traffic noise level during the daytime is about equal to the D NL and nighttime levels are 10 dBA lower. The standard is designed for sleep and speech protection and most jurisdictions apply the same criterion for all residential uses.
Typical structural attenuation is 12 to 17 dBA with open windows. With closed windows in good condition, the noise attenuation factor is around 20 dBA for an older structure and 25 dBA for a newer dwelling. Sleep and speech interference is therefore possible when exterior noise levels are about 57 to 62 dBA DNL with open windows and 65 to 70 dBA DNL if the windows are closed.
Levels of 55 to 60 dBA are common along collector streets and secondary arterials, while 65 to 70 dBA is a typical value for a primary/major arterial. Levels of 75 to 80 dBA are normal noise levels at the first row of development outside a freeway right -of-way. In order to achieve an acceptable interior noise environment, bedrooms facing secondary roadways need to be able to have their windows closed, those facing major roadways and freeways typically need special glass windows.
Annoyance
Attitude surveys are used for measuring the annoyance felt in a community for noises intruding into homes or affecting outdoor activity areas. In these surveys, it was determined that the causes Exhibit F - Noise Report
3 for annoyance include interference with speech, radio and television, house vibrations, and interference with sleep and rest. The DNL as a measure of noise has been found to provide a valid correlation of noise level and the percentage of people annoyed. People have been asked to judge the annoyance caused by aircraft noise and ground transportation noise. There continues to be disagreement about the relative annoyance of these different sources. When measuring the percentage of the population highly annoye d, the threshold for ground vehicle noise is about 50 dBA DNL. At a DNL of about 60 dBA, approximately 12 percent of the population is highly annoyed. When the DNL increases to 70 dBA, the percentage of the population highly annoyed increases to about 25 to 30 percent of the population. There is, therefore, an increase of about 2 percent per dBA between a DNL of 60 to 70 dBA. Between a DNL of 70 to 80 dBA, each decibel increase increases by about 3 percent the percentage of the population highly annoyed. Pe ople appear to respond more adversely to aircraft noise. When the DNL is 60 dBA, approximately 30 to 35 percent of the population is believed to be highly annoyed. Each decibel increase to 70 dBA adds about 3 percentage points to the number of people highly annoyed. Above 70 dBA, each decibel increase results in about a 4 percent increase in the percentag e of the population highly annoyed.
Exhibit F - Noise Report
4 TABLE 1 Definition of Acoustical Terms Used in this Report Term Definition
Decibel, dB A unit describing the amplitude of sound, equal to 20 times the logarithm to the base 10 of the ratio of the pressure of the sound measured to the reference pressure. The reference pressure for air is 20 micro Pascals.
Sound Pressure Level Sound pressure is the sound force per unit area, usually expressed in micro Pascals (or 20 micro Newtons per square meter), where 1 Pascal is the pressure resulting from a force of 1 Newton exerted over an area of 1 square meter. The sound pressure level i s expressed in decibels as 20 times the logarithm to the base 10 of the ratio between the pressures exerted by the sound to a reference sound pressure (e. g., 20 micro Pascals). Sound pressure level is the quantity that is directly measured by a sound leve l meter.
Frequency, Hz The number of complete pressure fluctuations per second above and below atmospheric pressure. Normal human hearing is between 20 Hz and 20,000 Hz. Infrasonic sound are below 20 Hz and Ultrasonic sounds are above 20,000 Hz.
A-Weighted Sound
Level, dBA
The sound pressure level in decibels as measured on a sound level meter using the A-weighting filter network. The A-weighting filter de-emphasizes the very low and very high frequency components of the sound in a manner similar to the frequency response of the human ear and correlates well with subjective reactions to noise.
Equivalent Noise Level,
Leq
The average A-weighted noise level during the measurement period.
Lmax, Lmin The maximum and minimum A -weighted noise level during the measurement period.
L01, L10, L50, L90 The A-weighted noise levels that are exceeded 1%, 10%, 50%, and 90% of the time during the measurement period.
Day/Night Noise Level,
Ldn or DNL
The average A -weighted noise level during a 24 -hour day, obtained after addition of 10 decibels to levels measured in the night between 10:00 pm and 7:00 am.
Community Noise
Equivalent Level,
CNEL
The average A -weighted noise level during a 24 -hour day, obtained after addition of 5 decibels in the evening from 7:00 pm to 10:00 pm and after addition of 10 decibels to sound levels measured in the night between 10:00 pm and 7:00 am.
Ambient Noise Level The composite of noise from all sources near and far. The normal or existing level of environmental noise at a given location.
Intrusive That noise which intrudes over and above the existing ambient noise at a given location. The relative intrusiveness of a sound depends upon its amplitude, duration, frequency, and time of occurrence and tonal or informational content as well as the prevailing ambient noise level.
Source: Handbook of Acoustical Measurements and Noise Control, Harris, 1998.
Exhibit F - Noise Report
5 TABLE 2 Typical Noise Levels in the Environment
Common Outdoor Activities
Noise Level (dBA)
Common Indoor Activities
110 dBA Rock band
Jet fly-over at 1,000 feet
100 dBA
Gas lawn mower at 3 feet
90 dBA
Diesel truck at 50 feet at 50 mph Food blender at 3 feet 80 dBA Garbage disposal at 3 feet
Noisy urban area, daytime
Gas lawn mower, 100 feet 70 dBA Vacuum cleaner at 10 feet Commercial area Normal speech at 3 feet
Heavy traffic at 300 feet 60 dBA
Large business office
Quiet urban daytime 50 dBA Dishwasher in next room
Quiet urban nighttime 40 dBA Theater, large conference room Quiet suburban nighttime
30 dBA Library
Quiet rural nighttime Bedroom at night, concert hall
(background)
20 dBA
Broadcast/recording studio
10 dBA
0 dBA
Source: Technical Noise Supplement (TeNS), California Department of Transportation, September 2013.
Exhibit F - Noise Report
6 Regulatory Background
A summary of the applicable regulatory criteria is provided below.
City of San José
City of San José General Plan. The Environmental Leadership Chapter in the Envision San José 2040 General Plan sets forth policies with the goal of minimizing the impact of noise on people through noise reduction and suppression techniques, and through appropriate land use policies in the City of San José. The following policies are applicable to the proposed project:
EC-1.2 Minimize the noise impacts of new development on land uses sensitive to increased noise levels (Categories 1, 2, 3 and 6) by limiting noise generation and by requiring use of noise attenuation measures such as acoustical enclosures and sound barriers, where feasible. The City considers significant noise impacts to occur if a project would:
• Cause the DNL at noise sensitive receptors to increase by five dBA DNL or more where the noise levels would remain “Normally Acceptable;” or
• Cause the DNL at noise sensitive receptors to increase by three dBA DNL or more where noise levels would equal or exceed the “Normally Acceptable” level.
EC-1.3 Mitigate noise generation of new nonresidential land uses to 55 dBA DNL at the property line when located adjacent to existing or planned noise sensitive residential and public/quasi-public land uses.
EC-1.6 Regulate the effects of operational noise from existing and new industrial and commercial development on adjacent uses through noise standards in the City’s Municipal Code.
Exhibit F - Noise Report
7 Source: City of San José General Plan – Envision San José 2040
City of San José Municipal Code
Zoning Code 20.50.300.B.4
The sound pressure level generated by any use or combination of uses shall not exceed the decibel level at any property line as shown in Table 20-135, except upon issuance and in compliance with a Conditional Use Permit as provided in Chapter 20.100.
Exhibit F - Noise Report
8 Existing Noise Environment
The project site is located on the northwest corner of the intersection of Endicott Boulevard and Hayes Avenue, southwest of the Union Pacific Railroad (UPRR) tracks and Monterey Highway, in the City of San José. Single-family residences along Lily Ann Way adjoin the western property line of the site.
The noise environment at the site and in the surrounding area results from a combination of traffic noise from Monterey Highway, Hayes Avenue, Endicott Boulevard, and Blossom Hill Road, as well as UPRR train noise, and jet aircraft noise associated with San José Mineta International Airport. A portion of the site is located within the 70 to 75 dBA DNL San José General Plan 2035 Traffic Noise Contours, with the remaining portion of the site located within the 65 to 70 dBA DNL noise contours.
On-site operations currently include the use of a flatbed delivery truck, forklifts for moving equipment and materials around the site and loading/unloading deliveries, the testing and demonstration of operating rental equipment, and pressure washer cleaning of equipment.
A noise monitoring survey consisting of one long-term (LT-1) and three short-term (ST-1 through ST-3) noise measurements was made between Monday, January 8, 2024, and Thursday, January 11, 2024. All measurement locations are shown in Figure 1.
Long-term noise measurement LT -1 was made at the western property line of the site , approximately 180 feet southwest of the centerline of the UPRR tracks. Hourly average noise levels at LT-1 typically ranged from 59 to 73 dBA Leq during daytime hours (7:00 a.m. and 10:00 p.m.) and from 51 to 65 dBA Leq during nighttime hours (10:00 p.m. and 7:00 a.m.). The day-night average noise level was 67 dBA DNL on Tuesday, January 9, 2024 and on Wednesday , January 10, 2024. The daily trend in noise levels at LT-1 is shown in Figures A1 through A4 of Appendix A.
Short-term noise measurements ST -1 through ST -3 were made simultaneously with LT -1 on Monday, January 8, 2024 between 9:10 a.m. and 9:30 a.m. As shown in Figure 1, ST-1 was made Exhibit F - Noise Report
9 at the northwest corner of the site, approximately 45-feet south of the centerline of Hayes Avenue.
Traffic noise typically ranged from 54 to 72 dBA at this location. A freight train with two engines and 24 cars generated noise levels up to 82 dBA. Jet fly overs occurred every few minutes, and generated noise levels ranging from 63 to 66 dBA. The 10 -minute average noise levels measured at ST-1 were 67 dBA Leq between 9:10 and 9:20 a.m., and 60 dBA Leq between 9:20 and 9:30 a.m.
ST-2 was made at the east corner of the site, approximately 45 -feet north of the centerline of Endicott Boulevard. Traffic noise typically ranged from 56 to 73 dBA at this location. Jet flyovers were also a major noise source, ranging from 66 to 68 dBA. Th e 10-minute average noise level measured at ST-2 was 63 dBA Leq between 9:40 and 9:50 a.m..
ST-3 was made at the southwest corner of the site, approximately 100 -feet northwest of the centerline of Endicott Boulevard. Traffic noise typically ranged from 51 to 63 dBA at this location.
Jet flyovers were also a major noise source, ranging from 65 to 68 dBA. Brief forklift noise ranged from 58 to 79 dBA. The 10-minute average noise level measured at ST-3 was 60 dBA Leq between 10:00 and 10:10 a.m.. Table 3 shows the noise levels measured at ST-1 through ST-3.
TABLE 3 Summary of Short-Term Noise Measurements (dBA)
Noise Measurement
Location Date, Time Measured Noise Level, dBA
Lmax L(1) L(10) L(50) L(90) Leq
ST-1a: Northwest
corner of site
1/8/2024,
9:10-9:20 a.m. 82 80 66 59 56 67
ST-1b: Northwest
corner of site
1/8/2024,
9:20-9:30 a.m. 67 66 63 58 55 60
ST-2: East corner of
site
1/8/2024,
9:40-9:50 a.m. 73 70 66 62 59 63
ST-3: Southwest
corner of site
1/8/2024,
10:00-10:10 a.m. 79 68 63 56 53 60
In addition to the long -term and short -term noise measurements, additional on -site noise measurements were made for various types of noise generating equipment that may be used at the site. All equipment noise was measured at a distance of 25 -feet. The noise levels ranged from 58 to 89 dBA. Typically, only one piece of equipment would be operating at a time, and for a brief period. The noise levels of the equipment are listed below in Table 4.
Exhibit F - Noise Report
10 TABLE 4 Summary of Equipment Noise at 25-Feet (dBA)
Equipment Measured Noise Level, dBA
Flatbed Delivery Truck 75
Forklift (driving) 58 to 62
Forklift (back up alarm) 68 to 70
Forklift (moving materials) 80
Pressure Washer (large) 80 to 86
Pressure Washer (small) 76
Trencher 82 to 89
Skid Steer 75
Water Trailer 78 to 82
Sod Cutter 80 to 89
Scissor Lift (idle) 75
Scissor Lift (back up alarm) 79
Wood Chipper 86 to 87
Exhibit F - Noise Report
11 FIGURE 1 Aerial Image of the Project Site Plan, Surrounding Area, and Noise Measurement Locations
Source: Google Earth, 2024.
Exhibit F - Noise Report
12 NOISE IMPACTS AND MITIGATION MEASURES
This section describes the significance criteria used to evaluate project impacts and presents mitigation measures, where necessary, to reduce project impacts to less-than-significant levels.
Significance Criteria
According to Policy EC -1.2 of the City’s General Plan, a significant permanent noise increase would occur if the project would increase noise levels at noise-sensitive receptors by 3 dBA DNL or more where ambient noise levels exceed the “normally acceptable” noise level standard. Where ambient noise levels are at or below the “normally acceptable” noise level standard, noise level increases of 5 dBA DNL or more would be considered significant. The City’s General Plan defines the “normally acceptable” outdoo r noise level standard for the nearby residential land uses to be 60 dBA DNL. Existing ambient levels, based on the measurements made in the project vicinity, exceed 60 dBA DNL. Therefore, a significant impact would occur if noise due to the proposed project would permanently increase ambient levels by 3 dBA DNL.
Under the City’s Noise Element and the City’s Municipal Code , noise levels from new nonresidential building equipment shall not exceed a noise level of 55 dBA DNL at receiving residential land uses. Noise -sensitive receptors bordering the site would include the existing residences to the west and south of the project site.
Impact 1: Permanent Noise Level Increase/Exceed Applicable Standards. The proposed project would not result in a substantial permanent noise level increase at residential uses. This is a less than significant impact.
Rental Equipment
Construction equipment will occasionally be operated on site for maintenance purposes and for customer demonstrations. It is conservatively assumed that these operations would occur for approximately ten minutes of each hour from 7:00 a.m. to 5:00 p.m. On-site noise measurements were made for a variety of equipment (Table 4). Noise levels for the equipment ranged from 58 to 89 dBA at 25-feet. With the reconfiguration of the site operations, rental equipment will be relocated away from the western residential property line to the east side of the site, closer to the roadways and train tracks. The equipment noise at nearby residences will also be shielded by the new building and existing 6-foot perimeter wall. Operating a variety of equipment near the center of the equipment yard throughout the day would generate noise levels ranging from 41 to 51 dBA DNL at the nearest residences considering attenuation from the building and perimeter wall.
Project Traffic Increase
A traffic study was not prepared for the proposed project. The proposed project is not expected to increase traffic volumes and would not contribute to a traffic noise increase. For all surrounding receptors, project trips would not measurably contribute to ambient noise levels in the area (0 dBA DNL increase).
Exhibit F - Noise Report
13 Mechanical Equipment
Heating, ventilation, and air conditioning (HVAC) units are typically part of commercial buildings.
These types of units typically cycle on and off during daytime hours of operation. Details pertaining to the mechanical equipment planned at the proposed sales building, such as specific type of units, quantities of units, locations of units, and noise levels generated by the units are unknown at this time. The applicant has indicated th at the building would include ground mounted condensing units. Typical air handling units for buildings of this size typically generate noise levels up to 62 dBA at a distance of 20 feet. Assuming all equipment is running simultaneously, noise levels generated by the air handling units would be up to 48 dBA DNL at the nearest residences, considering attenuation from the perimeter wall. For all surrounding receptors, mechanical equipment noise would not measurably contribute to ambient noise levels in the area (0 dBA DNL increase).
Forklift and Maintenance
Forklifts would be used when loading and unloading trucks. One propane forklift would continue to be used intermittently throughout the daytime hours. With the reconfiguration of the site, forklift operations would now occur on the east side of the site and would be mostly shielded receptors located to the west . Factoring in the expected attenuation from the new building and the 6-foot- tall perimeter wall, forklift noise is expected to be up to 39 dBA DNL, and well below the existing DNL at the residential property lines. Therefore, thresholds in the General Plan and Municipal Code would not be exceeded, and forklift noise would not measurably contribute to ambient noise levels in the area (0 dBA DNL increase).
Parking Lot Noise
Small s urface parking lot s for passenger cars would be located in the northwestern and southwestern corners of the site. Noise sources associated with the use of the parking lots would include vehicular circulation, loud engines, door slams, and human voices. The maximum noise level of a passing car at 15 mph typically ranges from 45 to 55 dBA Lmax at a distance of 100 feet.
The noise generated during an engine start is similar. Door slams cause slightly lower noise levels.
The hourly average noise levels r esulting from all of these noise -generating activities in a busy parking lot typically ranges from 40 to 50 dBA Leq at a distance of 100 feet from the parking area.
Parking lot operation is only expected between 7:00 a.m. and 5:00 p.m. Typical hourly operations would include a few cars at any time, which would result in lower levels.
When the noise source is positioned at the center of the parking lot areas, noise levels generated at parking lots at the site would be up to 38 dBA DNL, well below the existing DNL at the residential property line. Attenuation from the perimeter wall is assumed. Noise levels resulting from parking activities would be well below ambient noise levels due existing transportation noise , and the proposed parking lot/parking activities would not measurably contribute to ambient noise levels in the area (0 dBA DNL increase).
Exhibit F - Noise Report
14 Truck Deliveries
Truck delivery noise would include maneuvering activities occurring at the loading zone , which would likely occur on the east side of the proposed building, on the eastern portion of the project site. All trucks would access the site from Hayes Avenue. On-site flatbed delivery truck noise was observed to be 75 dBA at 25-feet. The delivery truck would typically enter and exit the site a few times per day. The new building and perimeter wall would shield the nearby residences from much of the truck noise. Fla tbed truck noise is expected to be up to 40 dBA DNL, and well below the existing DNL at the residential property lines. Thresholds in the General Plan and Municipal Code would not be exceeded, and truck noise would not measurably contribute to ambient noise levels in the area (0 dBA DNL increase).
Wash Pad Operations
The project currently has a wash pad located on the project site, which would continue to be used under project conditions. However, since the wash pad is part of existing on -site operations, this is considered part of the existing ambient noise environmen t and would not be a new noise - generating source produced by the proposed project.
Total Combined Project-Generated Noise
The operational noise levels produced by the proposed project combined (i.e., rental equipment, traffic, mechanical equipment, forklift, parking lot, and truck loading/unloading activities) would generate noise levels up to 53 dBA DNL at the nearest residences, well below the existing ambient noise levels (65 to 67 dBA DNL), and would not exceed 55 dBA DNL at the land uses surrounding the site.
Mitigation Measure 1: None Required
Exhibit F - Noise Report
15 APPENDIX A
Exhibit F - Noise Report
16 Exhibit F - Noise Report
17 Exhibit F - Noise Report
18 Exhibit F - Noise Report