Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W
-
-
-
-
GREEN DESIGN
-
-
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
6/3/2025
PLACE
Project:
Consultants:
Owner:
19700 S VERMONT AVE, #100
TORRANCE, CA 90502
Plan Check Number: H24-057
VICINITY MAP PROJECT DATA
OVERALLL SITE PLAN
DAB-A1.1
SITE PLAN KEYNOTES SITE PLAN GENERAL NOTES
SITE PLAN GENERAL NOTES
Property owner
Assossor's Parcel Number
Applicant's respresentative
Zoning
SITE
BUILDING ADDRESS
CODE ANALYSIS
Exhibit D - Permit Plan Set Page 1
Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W
-
-
-
-
GREEN DESIGN
-
-
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
6/5/2025
PLACE
Project:
Consultants:
Owner:
Plan Check Number: H24-057
FIRE ACCESS SITE PLAN
DAB-A1.1F
6/3/2025
2334 Lundy Place LLC,
a Delaware limited liability company
Exhibit D - Permit Plan Set Page 2
Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W
-
-
-
-
GREEN DESIGN
-
-
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
6/5/2025
PLACE
Project:
Consultants:
Owner:
Plan Check Number: H24-057
OVERALL FLOOR PLAN
DAB-A2.1
KEYNOTES - FLOOR PLAN GENERAL NOTES - FLOOR PLAN
PAINT NOTES
FLOOR SLAB AND POUR STRIPS REQ. WALL LEGEND - ALL FLOOR PLANS 6/3/2025
2334 Lundy Place LLC,
a Delaware limited liability company
Exhibit D - Permit Plan Set Page 3
Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W
-
-
-
-
GREEN DESIGN
-
-
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
6/5/2025
PLACE
Project:
Consultants:
Owner:
Plan Check Number: H24-057
ENLARGED FLOOR PLAN
DAB-A2.2
KEYNOTES - FLOOR PLAN GENERAL NOTES - FLOOR PLAN
PAINT NOTES
FLOOR SLAB AND POUR STRIPS REQ. WALL LEGEND - ALL FLOOR PLANS 6/3/2025
2334 Lundy Place LLC,
a Delaware limited liability company
Exhibit D - Permit Plan Set Page 4
Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W
-
-
-
-
GREEN DESIGN
-
-
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
6/5/2025
PLACE
Project:
Consultants:
Owner:
Plan Check Number: H24-057
ELEVATION
DAB-A3.1
GLAZING LEGEND
KEYNOTES - ELEVATIONS GENERAL NOTES - ELEVATIONS ELEVATION COLOR LEGEND/SCHED.
WALL ARTICULATION
6/3/2025
2334 Lundy Place LLC,
a Delaware limited liability company
Exhibit D - Permit Plan Set Page 5
SECTION
DAB-A4.1
Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W
-
-
-
-
GREEN DESIGN
-
-
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
6/5/2025
PLACE
Project:
Consultants:
Owner:
Plan Check Number: H24-057
6/3/2025
2334 Lundy Place LLC,
a Delaware limited liability company
Exhibit D - Permit Plan Set Page 6
Exhibit D - Permit Plan Set Page 7
Exhibit D - Permit Plan Set Page 8
DRAWING NUMBER: PRELIMINARY GRADING PLANS
DRAWN BY: AMC CHECKED BY: DGR
SAN JOSE, CALIFORNIA
OF
FOR2334 LUNDY PLACE LLC, A DELAWARE
ORIGINAL ISSUE
DATE: 09.25.2024
CURRENT SET ISSUE
DATE: 7.15.2025
PERMIT SET / CONSTRUCTION ISSUE
DATE: TBD REVISIONS BY NO. 1st PLANNING SUBMITTAL 09.25.2024 DGR 1 KIER + WRIGHT PROJECT NUMBER: A24286
DEPARTMENT: CIVIL
8955 Research Drive
Irvine, CA 92618
Phone: (949) 508-0202
www.kierwright.com
Z:\2024\A24286\DWG\ENTITLEMENTS\A24286-PG.dwg [C1.0 TOPOGRAPHIC SURVEY] Plot: Tuesday, July 15, 2025 GARRETT READLER 3rd PLANNING SUBMITTAL 06.03.2025 DGR 3
OF __9_ SHEETS
2nd PLANNING SUBMITTAL 01.28.2025 DGR 2
LIMITED LIABILITY COMPANY
4th PLANNING SUBMITTAL 07.17.2025 3
NORTH
C1.0
TOPOGRAPHIC SURVEY
1 NOTE
SA
BBREVIATIONS
UTILITY NOTE: THIS SITE HAS FIBER OPTIC
LINES LOCATED ON OR ADJACENT TO IT.
LUNDY PLACE
TRADE ZONE BOULEVARD
TACOURT ROB
LEGEND
DEMOLITION NOTE: A DEMOLITION PLAN
SHALL BE PROVIDED UPON APPROVAL OF
THESE PRELIMINARY GRADING PLANS BY
THE PLANNING DEPARTMENT. A BUILDING
DEMOLITION PERMIT APPLICATION SHALL
BE FILED ALONG WITH A GRADING &
DRAINAGE PERMIT APPLICATION UPON
ENTITLEMENT APPROVAL.
2334 LUNDY PLACE
Exhibit D - Permit Plan Set Page 9
DRAWING NUMBER: PRELIMINARY GRADING PLANS
DRAWN BY: AMC CHECKED BY: DGR
SAN JOSE, CALIFORNIA
OF
FOR2334 LUNDY PLACE LLC, A DELAWARE
ORIGINAL ISSUE
DATE: 09.25.2024
CURRENT SET ISSUE
DATE: 7.15.2025
PERMIT SET / CONSTRUCTION ISSUE
DATE: TBD REVISIONS BY NO. 1st PLANNING SUBMITTAL 09.25.2024 DGR 1 KIER + WRIGHT PROJECT NUMBER: A24286
DEPARTMENT: CIVIL
8955 Research Drive
Irvine, CA 92618
Phone: (949) 508-0202
www.kierwright.com
Z:\2024\A24286\DWG\ENTITLEMENTS\A24286-PG.dwg [C1.1 DEMOLITION PLAN] Plot: Tuesday, July 15, 2025 GARRETT READLER 3rd PLANNING SUBMITTAL 06.03.2025 DGR 3
OF __9_ SHEETS
2nd PLANNING SUBMITTAL 01.28.2025 DGR 2
LIMITED LIABILITY COMPANY
4th PLANNING SUBMITTAL 07.17.2025 3
NORTH
C1.1
DEMOLITION PLAN
2 LUNDY PLACE
TRADE ZONE BOULEVARD
TACOURT ROB
LEGEND
PERMITTING NOTE:
CONSTRUCTION ACTIVITIES IN THE
PUBLIC RIGHT-OF-WAY MAY REQUIRE AN
ENCROACHMENT PERMIT. EXISTING VEGETATION NOTE:
REFER TO LANDSCAPE PLANS &
ARBORIST'S REPORT FOR FURTHER
INFORMATION ON EXISTING TREES &
VEGETATION TO BE PRESERVED OR
REMOVED AS PART OF THIS PROJECT. DEMOLITION NOTE:
THIS DEMOLITION PLAN IS PRELIMINARY
IN NATURE AND FURTHER DEMOLITION
RECOMMENDATIONS & NOTES MAY BE
PROPOSED UPON ENTITLEMENT
APPROVAL FROM THE CITY OF SAN JOSE.
FURTHER DETAIL PERTAINING TO THE
PROTECTION OR REMOVAL OF EXISTING
SITE FEATURES, STRUCTURES, UTILITIES
(ABOVE & BELOW GROUND) AND SO ON
MAY BE PROVIDED UPON SUBMITTAL OF
CONSTRUCTION DOCUMENTS FOR
BUILDING DEMOLITION & GRADING AND
DRAINAGE PERMIT APPROVALS. THE
CONTRACTOR SHALL BE RESPONSIBLE
FOR VERIFYING EXISTING SITE
CONDITIONS AND ADHERING TO THE
DEMOLITION & CONSTRUCTION NOTES &
RECOMMENDATIONS PROVIDED HEREON.
2334 LUNDY PLACE
Exhibit D - Permit Plan Set Page 10
NEW BUILDING
TOTAL AREA: 132,419 SF
FF 54.5
DRAWING NUMBER: PRELIMINARY GRADING PLANS
DRAWN BY: AMC CHECKED BY: DGR
SAN JOSE, CALIFORNIA
OF
FOR2334 LUNDY PLACE LLC, A DELAWARE
ORIGINAL ISSUE
DATE: 09.25.2024
CURRENT SET ISSUE
DATE: 7.15.2025
PERMIT SET / CONSTRUCTION ISSUE
DATE: TBD REVISIONS BY NO. 1st PLANNING SUBMITTAL 09.25.2024 DGR 1 KIER + WRIGHT PROJECT NUMBER: A24286
DEPARTMENT: CIVIL
8955 Research Drive
Irvine, CA 92618
Phone: (949) 508-0202
www.kierwright.com
Z:\2024\A24286\DWG\ENTITLEMENTS\A24286-PG-GP.dwg [C2.0 PRELIMINARY GRADING PLAN] Plot: Tuesday, July 15, 2025 GARRETT READLER 3rd PLANNING SUBMITTAL 06.03.2025 DGR 3
OF __9_ SHEETS
2nd PLANNING SUBMITTAL 01.28.2025 DGR 2
LIMITED LIABILITY COMPANY
4th PLANNING SUBMITTAL 07.17.2025 3
NORTH
C2.0
GRADING PLAN
TAROB COURT LUNDY PLACE
TRADE ZONE BOULEVARD
3 PROPOSED EXISTING DESCRIPTION
STORM DRAIN CATCH BASIN
STORM DRAIN JUNCTION BOX
STORM DRAIN MANHOLE
SPOT ELEVATION
STORM DRAIN LINE
OVERLAND RELEASE FLOW
GRADING LEGEND
PROPOSED EXISTING DESCRIPTION
BIOTREATMENT SOIL MIX
BOTTOM OF POND BSM
FINISHED FLOOR FLOW LINE PAVEMENT RIM ELEVATION STORM DRAIN STORM DRAIN MANHOLE TOP OF CURB TOP OF POND BSM TOP OF WALL TOP OF CURB
GRADING ABBREVIATIONS FLOW THROUGH PLANTER
AREA DRAIN CURB SLOT
TYPICAL SECTION AT
LOADING DOCK
2334 LUNDY PLACE
Exhibit D - Permit Plan Set Page 11
DRAWING NUMBER: PRELIMINARY GRADING PLANS
DRAWN BY: AMC CHECKED BY: DGR
SAN JOSE, CALIFORNIA
OF
FOR2334 LUNDY PLACE LLC, A DELAWARE
ORIGINAL ISSUE
DATE: 09.25.2024
CURRENT SET ISSUE
DATE: 7.15.2025
PERMIT SET / CONSTRUCTION ISSUE
DATE: TBD REVISIONS BY NO. 1st PLANNING SUBMITTAL 09.25.2024 DGR 1 KIER + WRIGHT PROJECT NUMBER: A24286
DEPARTMENT: CIVIL
8955 Research Drive
Irvine, CA 92618
Phone: (949) 508-0202
www.kierwright.com
Z:\2024\A24286\DWG\ENTITLEMENTS\A24286-PG-PUP.dwg [C3.0 UTILITY PLAN] Plot: Tuesday, July 15, 2025 GARRETT READLER 3rd PLANNING SUBMITTAL 06.03.2025 DGR 3
OF __9_ SHEETS
2nd PLANNING SUBMITTAL 01.28.2025 DGR 2
LIMITED LIABILITY COMPANY
4th PLANNING SUBMITTAL 07.17.2025 3
LEGEND
NORTH
C3.0
UTILITY PLAN
TAROB COURT LUNDY PLACE
TRADE ZONE BOULEVARD
4 2334 LUNDY PLACE
Exhibit D - Permit Plan Set Page 12
DRAWING NUMBER: PRELIMINARY GRADING PLANS
DRAWN BY: AMC CHECKED BY: DGR
SAN JOSE, CALIFORNIA
OF
FOR2334 LUNDY PLACE LLC, A DELAWARE
ORIGINAL ISSUE
DATE: 09.25.2024
CURRENT SET ISSUE
DATE: 7.15.2025
PERMIT SET / CONSTRUCTION ISSUE
DATE: TBD REVISIONS BY NO. 1st PLANNING SUBMITTAL 09.25.2024 DGR 1 KIER + WRIGHT PROJECT NUMBER: A24286
DEPARTMENT: CIVIL
8955 Research Drive
Irvine, CA 92618
Phone: (949) 508-0202
www.kierwright.com
Z:\2024\A24286\DWG\ENTITLEMENTS\A24286-PG-SWQ.dwg [C4.0 STORM WATER QUALITY CONTROL PLAN] Plot: Tuesday, July 15, 2025 GARRETT READLER 3rd PLANNING SUBMITTAL 06.03.2025 DGR 3
OF __9_ SHEETS
2nd PLANNING SUBMITTAL 01.28.2025 DGR 2
LIMITED LIABILITY COMPANY
4th PLANNING SUBMITTAL 07.17.2025 3
NORTH
C4.0
STORM WATER QUALITY CONTROL
PLAN
STORMWATER LEGEND
LUNDY PLACE
TRADE ZONE BOULEVARD
5 TACOURT ROB
DMA 1
DMA 2
DMA 3
DMA
DMA 5
DMA 4
DMA 7 6 TCM 1
TCM 2
TCM 3
DMA 8
DMA 9
DMA 10
DMA 11
TCM 10
TCM
5 TCM
4 TCM
7 TCM
6 TCM
8 TCM
9 DMA TCM
EQ
EQ
EQ
EQ
2334 LUNDY PLACE
Exhibit D - Permit Plan Set Page 13
DRAWING NUMBER: PRELIMINARY GRADING PLANS
DRAWN BY: AMC CHECKED BY: DGR
SAN JOSE, CALIFORNIA
OF
FOR2334 LUNDY PLACE LLC, A DELAWARE
ORIGINAL ISSUE
DATE: 09.25.2024
CURRENT SET ISSUE
DATE: 7.15.2025
PERMIT SET / CONSTRUCTION ISSUE
DATE: TBD REVISIONS BY NO. 1st PLANNING SUBMITTAL 09.25.2024 DGR 1 KIER + WRIGHT PROJECT NUMBER: A24286
DEPARTMENT: CIVIL
8955 Research Drive
Irvine, CA 92618
Phone: (949) 508-0202
www.kierwright.com
Z:\2024\A24286\DWG\ENTITLEMENTS\A24286-PG-SWQ.dwg [C4.1 STORM WATER QUALITY CONTROL CALCULATIONS] Plot: Tuesday, July 15, 2025 GARRETT READLER 3rd PLANNING SUBMITTAL 06.03.2025 DGR 3
OF __9_ SHEETS
2nd PLANNING SUBMITTAL 01.28.2025 DGR 2
LIMITED LIABILITY COMPANY
4th PLANNING SUBMITTAL 07.17.2025 3
C4.1
PRELIMINARY STORM WATER QUALITY
CONTROL CALCULATIONS AND NOTES
6 A. PROPERTY INFORMATION:
B. RESPONSIBLE PARTY FOR MAINTENANCE:
PROJECT SITE INFORMATION
1. SOILS TYPE: SITE CLASS D
2. GROUND WATER DEPTH: 8.5' BELOW GROUND SURFACE
3. NAME OF RECEIVING BODY: LOWER PENITENCIA CREEK TO LOWER COYOTE CREEK
4. FLOOD ZONE: AO .
5. FLOOD ELEVATION (IF APPLICABLE): N/A
OPERATION AND
MAINTENANCE INFORMATION
SOURCE CONTROL MEASURES:
SITE DESIGN MEASURES:
NOTES
CONTRACTOR SHALL INSTALL STORMWATER TREATMENT MEASURE SIGNAGE IN THE FORM OF A CITY APPROVED MEDALLION # STDM-19323-SSPS, OR EQUIVALENT. THE MEDALLION MUSTBE
COMMERCIAL GRADE STAINLESS-STEEL, ALUMINUM, BRASS OR BRONZE AND EITHER STAMPED FROM SHEET METAL OR CAST.
THE MEDALLION COLOR MUSTBE NONREFLECTIVE BLUE OR GREEN AND BE AFFIXED TO A
CLEAN, PREPARED SURFACE WITH ADHESIVES, FASTENERS OR HEAT AS RECOMMENDED BY THEMANUFACTURER. THE MEDALLION MUSTINCLUDE THE WORDS “STORMWATER TREATMENT MEASURE - DO NOT ALTER OR REMOVE” AND BE WEATHERPROOF.
MEDALLION SHALL BE INSTALLED ATEACH CURB OPENING LOCATION OR 10’ APART IF MULTIPLE CURB OPENINGS". IF THERE ARE NO CURB OPENING(S) THEN PLACE 10’ APART.
FOR INFORMATION ONLY: MEDALLION PART # STDM-19323-SSPS CAN BE PURCHASED THROUGH ALMETEK INDUSTRIES, INC.: WWW.ALMETEK.COM OR CALL (800) 248-2080. HOWEVER, THE CONTRACTOR MAY PURCHASE FROM ANY SOURCE SUBJECT TO REVIEW AND APPROVAL. CALL THECITY OF SAN JOSE ENVIRONMENTAL SERVICES DEPARTMENT AT (408) 945-3000 FOR MORE INFO.
ALL GREY COPY IS RAISED
UNLESS INDICATED OTHERWISE
EMBOSSING HEIGHT 0.040"
0.18" CORNER RADIUS
Ø 4.00"
SECTION VIEW
0.187"
BIOTREATMENT SOIL REQUIREMENTS: ··
BIORETENTION & FLOW-THROUGH
PLANTER NOTES:
2334 LUNDY PLACE
Exhibit D - Permit Plan Set Page 14
DRAWING NUMBER: PRELIMINARY GRADING PLANS
DRAWN BY: AMC CHECKED BY: DGR
SAN JOSE, CALIFORNIA
OF
FOR2334 LUNDY PLACE LLC, A DELAWARE
ORIGINAL ISSUE
DATE: 09.25.2024
CURRENT SET ISSUE
DATE: 7.15.2025
PERMIT SET / CONSTRUCTION ISSUE
DATE: TBD REVISIONS BY NO. 1st PLANNING SUBMITTAL 09.25.2024 DGR 1 KIER + WRIGHT PROJECT NUMBER: A24286
DEPARTMENT: CIVIL
8955 Research Drive
Irvine, CA 92618
Phone: (949) 508-0202
www.kierwright.com
Z:\2024\A24286\DWG\ENTITLEMENTS\A24286-PG-SWQ.dwg [C4.2 STORM WATER QUALITY CONTRO DETAILS] Plot: Tuesday, July 15, 2025 GARRETT READLER 3rd PLANNING SUBMITTAL 06.03.2025 DGR 3
OF __9_ SHEETS
2nd PLANNING SUBMITTAL 01.28.2025 DGR 2
LIMITED LIABILITY COMPANY
4th PLANNING SUBMITTAL 07.17.2025 3
C4.2
STORM WATER QUALITY CONTROL
DETAILS
7 2334 LUNDY PLACE
Exhibit D - Permit Plan Set Page 15
TRADE ZONE BOULEVARD
LUNDY PLACE
TAROB COURT
LUNDY PLACE
TAROB COURT
TRADE ZONE BOULEVARD
NORT
H
B LEFT TURN IN @ TRADE ZONE BLVD.
D
TRUCK LOADING DOCK EXIT MANEUVERS &
LEFT TURN OUT @ LUNDY PL.
C
TRUCK LOADING DOCK PARKING MANEUVERS &
RIGHT TURN IN @ LUNDY PL. A
INTERNAL TRUCK DRIVE AISLE MANEUVER &
RIGHT TURN IN @ TRADE ZONE BLVD.
DRAWING NUMBER: PRELIMINARY GRADING PLANS
DRAWN BY: AMC CHECKED BY: DGR
SAN JOSE, CALIFORNIA
OF
FOR2334 LUNDY PLACE LLC, A DELAWARE
ORIGINAL ISSUE
DATE: 09.25.2024
CURRENT SET ISSUE
DATE: 7.15.2025
PERMIT SET / CONSTRUCTION ISSUE
DATE: TBD REVISIONS BY NO. 1st PLANNING SUBMITTAL 09.25.2024 DGR 1 KIER + WRIGHT PROJECT NUMBER: A24286
DEPARTMENT: CIVIL
8955 Research Drive
Irvine, CA 92618
Phone: (949) 508-0202
www.kierwright.com
Z:\2024\A24286\DWG\ENTITLEMENTS\A24286-PG-TRUCK TURNING.dwg [C5.0 - TRUCK TURNING] Plot: Tuesday, July 15, 2025 GARRETT READLER 3rd PLANNING SUBMITTAL 06.03.2025 DGR 3
OF __9_ SHEETS
2nd PLANNING SUBMITTAL 01.28.2025 DGR 2
LIMITED LIABILITY COMPANY
4th PLANNING SUBMITTAL 07.17.2025 3
C5.0
TRUCK TURNING EXHIBIT
8 2334 LUNDY PLACE
Exhibit D - Permit Plan Set Page 16
NEW BUILDING
CONST. TYPE IIIB
TOTAL AREA: 132,419 SF
BASED ON 2022 CFC AND SJFD REQUIREMENTS:
R
EQUIRED FIRE FLOW "BEFORE" REDUCTION IS APPLIED 7,750 GPM REQUIRED FIRE FLOW "AFTER" REDUCTION IS APPLIED 5,813 GPM
TAROB COURT LUNDY PLACE
TRADE ZONE BOULEVARD
26' MIN. FIRE ACCESS LANE
LEGEND NORTH
FP-1
FIRE ACCESS PLAN
9 DRAWING NUMBER: PRELIMINARY GRADING PLANS
DRAWN BY: AMC CHECKED BY: DGR
SAN JOSE, CALIFORNIA
OF
FOR2334 LUNDY PLACE LLC, A DELAWARE
ORIGINAL ISSUE
DATE: 09.25.2024
CURRENT SET ISSUE
DATE: 7.15.2025
PERMIT SET / CONSTRUCTION ISSUE
DATE: TBD REVISIONS BY NO. 1st PLANNING SUBMITTAL 09.25.2024 DGR 1 KIER + WRIGHT PROJECT NUMBER: A24286
DEPARTMENT: CIVIL
8955 Research Drive
Irvine, CA 92618
Phone: (949) 508-0202
www.kierwright.com
Z:\2024\A24286\DWG\ENTITLEMENTS\A24286-PG-PUP-FIRE FLOW.dwg [FP-1 FIRE ACCESS PLAN] Plot: Tuesday, July 15, 2025 GARRETT READLER 3rd PLANNING SUBMITTAL 06.03.2025 DGR 3
OF __9_ SHEETS
2nd PLANNING SUBMITTAL 01.28.2025 DGR 2
LIMITED LIABILITY COMPANY
4th PLANNING SUBMITTAL 07.17.2025 3 2334 LUNDY PLACE
Exhibit D - Permit Plan Set Page 17
TRADE ZONE BOULEVARD
LUNDY PLACE
TRADE ZONE BOULEVARD
LUNDY PLACE
PARCEL 1
16.7'
15.6'
15.2'
15.0'
15.0'
11.0'
10.0'
35.0'
PRELIMINARY LANDSCAPE PLAN
SCALE: 1" = 40'-0"
LC1.1
PRELIMINARY
PLAN
LANDSCAPE
Bio-Swale Mix - Compact
Lbs./Ac. Species / Common Name -- 48 lbs per acre
28 Festuca rubra, Molate Fescue
9 Deschampsia ceaspitosa, Tufted Hairgrass
7 Carex divulsa, Berkeley Sedge
‘ ’
Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W
-
-
-
-
GREEN DESIGN
-
-
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
7/17/2025
PLACE
Project:
Consultants:
Owner:
2334 Lundy Place LLC,
a Delaware limited liability company
Plan Check Number: H24-057
1464 Popinjay Drive
Reno, NV.
email: [email protected]
p: 775 829 1364
1st Planning Submittal 9/25/2025
2nd Planning Submittal 1/28/2025
3rd Planning Submittal 6/03/2025
6/3/2025
Exhibit D - Permit Plan Set
EXIST. TREE REPORT & MITIGATION PLAN LC1.2
EXIST. TREE REPORT
& MITIGATION PLAN
Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W----
GREEN DESIGN--
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
7/17/2025
PLACE
Project:
Consultants:
Owner:
2334 Lundy Place LLC,
a Delaware limited liability company
Plan Check Number: H24-057
1464 Popinjay Drive
Reno, NV.
email: [email protected]
p: 775 829 1364
1st Planning Submittal 9/25/2025
2nd Planning Submittal 1/28/2025
3rd Planning Submittal 6/03/2025
6/3/2025
Exhibit D - Permit Plan Set
TRADE ZONE BOULEVARD
LUNDY PLACE
TRADE ZONE BOULEVARD
LUNDY PLACE
PARCEL 1 PARCEL 1
8 8
8 1
5 7
8 6
6 4
4 3
2 PRELIMINARY LANDSCAPE HYDROZONE PLAN
SCALE: 1" = 40'-0"
LC2.1
PRELIMINARY
HYDROZONE
PLAN
Water Efficient Landscape Budget Calculations
IRRIGATION HYDRO-ZONE LEGEND
Reference Evapotranspiration (ETo) 45.3
MAWA - Regular Landscape Areas
MAWA = (ETo) x (0.62) x ((ETAF x LA)+(1-ETAF x SLA))
landscape area 52,216 s.f.
SLA 0 s.f.
ETAF 0.45 average ETAF for regular landscape areas must be 0.55 residential areas, and 0.45 for non-residential areas total area with SLA 52,216
mawa total 659,942 gallons per year
ETWU - Regular Landscape Areas
ETWU = (ETo) x (0.62) x ((ETAF x LA)+SLA))
hydro-zone
number
plant water use plant factor (PF) irrigation method irrigation efficiency ETAF (PF/IE) hydro-zone area ETAF x Area ETWU 1 low 0.2 drip 0.81 0.247 2,563 632.8 17,774
2 low 0.2 drip 0.81 0.247 4,097 1,011.6 28,412
3 low 0.2 drip 0.81 0.247 3,389 837 23,502
4 low 0.2 drip 0.81 0.247 3,720 919 25,798
5 low 0.2 drip 0.81 0.247 2,056 508 14,258
6 low 0.2 drip 0.81 0.247 21,511 5,311 149,175
7 low 0.2 drip 0.81 0.247 6,738 1,664 46,727
8 low 0.2 overhead spray 0.75 0.267 8,142 2,171 60,980
SLA --- 1.0 --- 1.00 1.000 0 0 0
ETWU totals 52,216 13,053.7 366,625
Total area with all zones and SLA 52,216
ETAF calculations
total ETAF x area 13,053.7
total area 52,216 s.f.
average ETAF 0.250
Average ETAF for Regular Landscape Areas must be 0.55 or below for residential areas, and
0.45 or below for non-residential areas.
ETWU calculations
ETWU = (ETo) x (0.62) x [((PF x HA) / IE)) + SLA]
Eto conv. factor PF x Area/IE SLA
EWTU= 45.30 .62 13,053.7 0
EWTU (gallon per year)= 366,625
TOTALS
MAWA total 659,942 gallons per year
ETWU total 366,625 gallons per year
44.4 Percentage reduction of Potable Irrigation Water
Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W
-
-
-
-
GREEN DESIGN
-
-
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
7/17/2025
PLACE
Project:
Consultants:
Owner:
2334 Lundy Place LLC,
a Delaware limited liability company
Plan Check Number: H24-057
1464 Popinjay Drive
Reno, NV.
email: [email protected]
p: 775 829 1364
1st Planning Submittal 9/25/2025
2nd Planning Submittal 1/28/2025
3rd Planning Submittal 6/03/2025
6/3/2025
Exhibit D - Permit Plan Set
TRADE ZONE BOULEVARD
LUNDY PLACE
TRADE ZONE BOULEVARD
LUNDY PLACE
TAROB COURT
PARCEL 1 PARCEL 1
c
Irrigation Controller
Location
CONNECTION TO IRRIGATION WATER
METER. (WATER METER PROVIDED BY
OTHERS)
IRRIGATION R.P. DEVICE TO BE
LOCATED WITHIN AN ENCLOSURE AND
WITH A CONCRETE BASE
ENSURE DEVICE COMPLIES WITH ALL
LOCAL AND CITY CODES AND
ORDINANCE.
DRIP ZONE 1
DRIP ZONE 3
DRIP ZONE 2
DRIP ZONE 4
DRIP ZONE 6
DRIP ZONE 5
DRIP ZONE 8 DRIP ZONE 7
DRIP ZONE
9 DRIP ZONE 11
DRI
P ZONE 10
SPRAY ZONE 1
SPRAY ZONE 2
SPRAY ZONE 3
LOW
SHRUB
LOW
SHRUB
LOW
SHRUB
LOW
SHRUB
LOW
SPRAY
LOW
SPRAY
LOW
SPRAY
LOW
SHRUB
LOW
SHRUB
LOW
SHRUB
LOW
SHRUB
LOW
SHRUB
LOW
SHRUB
LOW
SHRUB
LOW
SPRAY
LOW
SPRAY
LOW
TREE
LOW
TREE
LOW
TREE
LOW
TREE
LOW
TREE
DRIP ZONE 4
LOW
SPRAY
Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W
-
-
-
-
GREEN DESIGN
-
-
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
7/17/2025
PLACE
Project:
Consultants:
Owner:
2334 Lundy Place LLC,
a Delaware limited liability company
Plan Check Number: H24-057
1464 Popinjay Drive
Reno, NV.
email: [email protected]
p: 775 829 1364
1st Planning Submittal 9/25/2025
2nd Planning Submittal 1/28/2025
3rd Planning Submittal 6/03/2025
LC2.2
PRELIMINARY
IRRIGATION
PLAN
PRELIMINARY IRRIGATION PLAN
SCALE: 1" = 40'-0"
IRRIGATION PIPE SIZE CHART
IRRIGATION LEGEND:
TCM #1
TCM #3
TCM #2
TCM #10
TCM #9
TCM #8 TCM #7 TCM #6 TCM #5 TCM #4
6/3/2025
Exhibit D - Permit Plan Set
E-S
SITE
PHOTOMETRIC
Project Number:
Revision:
Date:
Drawn by:
Title:
Sheet:
C I V I L
STRUCTURAL
MECHANICAL
PLUMBING
ELECTRICAL
LANDSCAPE
SOILS ENGINEER
FIRE PROTECTION
K&W
-
-
-
-
GREEN DESIGN
-
-
2334 LUNDY
SAN JOSE, CA
tel: 949 862 2113
email: [email protected]
94610
oakland, ca
600 grand ave, suite 302
hpa, inc.
23445
M.D.
6/3/2025
PLACE
Project:
Consultants:
Owner:
Plan Check Number: H24-057
2334 Lundy Place LLC,
a Delaware limited liability company
Exhibit D - Permit Plan Set