Cities Index.
B - Climatec Installation Agreement

San Leandro City Council
January 2, 2024

Document
B - Climatec Installation Agreement
Meeting
January 2, 2024
Body
San Leandro City Council
Pages
17
Original file
6.4 MB
Text extracted from the city's file for reading and search. Open the original on legistar1.granicus.com. That file is the official record.

Keystone Technologies • Philadelphia PA • Phone (800) 464-2680 • www.keystonetech.com Specifications subject to change. Last revised on 02.24.21 KT-FLED35-R1A-UNV-8CSB-VDIM
COMPACT 35W GENERAL-PURPOSE LED FLOOD LIGHT

DESCRIPTION
Compact 35W General-Purpose LED Flood Light | 120–277V
Input |
3000–5000K | Bronze Housing | Multiple Mounting Options

APPLICATION
Building Mount or Ground Mount for outdoor illumination (landscapes, display signage, loading docks,
building façades, pathways, parking areas, and
other general site lighting requirements)

ELECTRICAL SPECIFICATIONS
Catalog Number Wattage Lumens Dimming CCT* Efficacy CRI Housing Color Mounting Input Voltage Rated Life Legacy Equivalent KT-FLED35-R1A-UNV-8CSB-VDIM 35W
4480 lm
0–10V
3000K 128 lm/W
>80 Bronze
Universal:
1/2” Knuckle
or yoke
5075 lm 4000K 145 lm/W 120–277V 50,000 hrs 150–175W MH
4900 lm 5000K 140 lm/W
* Color Uniformity: CCT (Correlated Color Temperature) range as per guidelines outlined in ANSI C78.377-2017

PRODUCT FEATURES
• Uniform, wide flood design (NEMA 7h × 7w distribution pattern) • Heavy-duty, die cast aluminum housing featuring built-in glare visor and tempered glass lens • Powered by Keystone 0–10V dimming LED drivers
• Keystone Color Select Technology: Adjustable CCT (3000K, 4000K, or 5000K) • Built-in dusk-to-dawn photocell behind translucent 3/4” threaded plug with anti-yellowing agent • Heavy-duty 1/2” knuckle mount with 90º adjustment and yoke mount options included • Ambient operating temperature: −30ºC/−22ºF to 45ºC/113ºF • UL listed for wet locations, IP65
• 0–10V dimming, 10% min
• Power Factor: >0.95
• THD: <20%
• LED chip lifetime: L70 >100,000 hrs @ 25ºC/77ºF ambient fixture temp • Meets FCC Part 15, Part B, Class A standards for conducted and radiated emissions • 18" input cable, pre-stripped
• Fixture impact rating IK07
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 Keystone Technologies • Philadelphia PA • Phone (800) 464-2680 • www.keystonetech.com Specifications subject to change. Last revised on 02.24.21

Page 2 of 5 ends

KT-FLED35-R1A-UNV-8CSB-VDIM
COMPACT 35W GENERAL-PURPOSE LED FLOOD LIGHT

PHOTOMETRIC SPECIFICATIONS

FLUX DISTRIBUTION
Zone Lumens % Luminaire
Forward Light 2,527 lm 53.2%
0º–30º 675 lm 14.2%
30º–60º 1,366 lm 28.8%
60º–80º 471 lm 9.9%
80º–90º 15 lm 0.3%
Back Light 2,181 lm 46.0%
0º–30º 656 lm 13.8%
30º–60º 1,223 lm 25.8%
60º–80º 297 lm 6.3%
80º–90º 5 lm 0.1%
Up Light 39 lm 0.8%
90º–100º 2 lm 0.0%
100º–180º 36 lm 0.8%
BUG* Rating
Asymmetrical Luminare Types
Type I, II, III, IV B2 U2 G1
Quadrilateral Symmetrical Luminare Types
Type V, Area Light B2 U2 G1
* Backlight, Uplight, Glare

ISOCANDELA PLOT
Cd: 171 (10%)
Cd: 274 (16%)
Cd: 428 (25%)
Cd: 684 (40%)
Cd: 1077 (63%)
Cd: 1710 (100%)
80º
60º
40º
20º
0º
−20º
−40º
−60º
−80º
−80º −60º −40º −20º 0º 20º 40º 60º 80º

LUMINOUS INTENSITY DISTRIBUTION
Average diffuse angle (50%): 114.3º
1Violet C0–C180
2Green C90–C270
3Orange G3
Unit: cd
180º
−150º
−120º
150º
120º
−30º
−60º
−90º 90º
60º
30º
0º
1 2
3 LIGHT DISTRIBUTION PATTERNS (Isometric view from above) Building exterior mounted at
15', 30º below horizontal
Ground mounted at 6" above ground,
10º above horizontal, shining towards building exterior wall at 14' away

0.1 fc

0.2 fc

0.5 fc

1.0 fc

2.0 fc

5.0 fc

10.0 fc
10'
20'
30'
40'
50'
10'
0'
20'
30'
40'
50'
20'
30'
20'
30'
40'
50'
60'
70'
10'
10'
0 10'
20'
30'
40'
50'
10'
0'
20'
30'
40'
50'
20'
30'
40'
50'
20'
10'
10'
0 2137
427
855
1282
1710
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 Keystone Technologies • Philadelphia PA • Phone (800) 464-2680 • www.keystonetech.com Specifications subject to change. Last revised on 02.24.21

Page 3 of 5 ends

KT-FLED35-R1A-UNV-8CSB-VDIM
COMPACT 35W GENERAL-PURPOSE LED FLOOD LIGHT

PHYSICAL SPECIFICATIONS

5.51"

5.51"

8.98"

6.97"

7.40"

7.40"

2.75"

2.75"

KNUCKLE MOUNT

YOKE MOUNT
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 Keystone Technologies • Philadelphia PA • Phone (800) 464-2680 • www.keystonetech.com Specifications subject to change. Last revised on 02.24.21

Page 4 of 5 ends

KT-FLED35-R1A-UNV-8CSB-VDIM
COMPACT 35W GENERAL-PURPOSE LED FLOOD LIGHT
Caution: Before installing, make
certain that AC power to the
fixture is off.

Caution: The electrical rating
of this product is 120–277V.

Installer must confirm that there
is 120–277V at the fixture
before installation.

GENERAL SETUP INSTRUCTIONS

GENERAL WIRING DIAGRAM
120–277V Input
DC Output Pre-wired leads
to LED load
Dimming wires to 0–10V
IEC-compliant control
Black (Line)
White (Neutral)
Purple (Dim+)
Red (+)
Gray (Dim−)
Black (−)
Green (Ground) LED Driver

PHOTOCELL ENABLE/DISABLE
This fixture is equipped with a dusk-to-dawn photocell
behind the translucent knock-out (KO) cover. Adjust the dip switch to enable (ON) or disable (OFF) the photocell function (see illustrations to the right). Fixture comes preset with photocell enabled unless otherwise noted.

COLOR SELECT (CCT) ADJUSTMENT
This fixture is equipped with Color Select technology.

There is an adjustable dip switch behind the translucent knock-out (KO) cover to change CCT between 5000K,
4000K, and 3000K (see illustrations to the right). Fixture comes preset at 5000K unless otherwise noted.

Photocell Enable /Disable
Color Select (CCT) Adjustment

ACCESSORIES (SOLD SEPARATELY)
Catalog Number Description
KT-FLED-SM-1-KIT Flood Light Wall Mount Kit
KT-FLED-RC-4-W 4" Round Flood Light Junction Box Cover, White KT-FLED-RC-4 4" Round Flood Light Junction Box Cover, Bronze DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 11 Color Select Designation
A 3500K, 4000K, 5000K
B 3000K, 4000K, 5000K
C 3000K, 3500K, 4000K, 5000K
D TBD
7 Distribution
A Wide (7 × 7)
B Narrow
C Very Narrow
10 Color
40 4000K
50 5000K
CS Color Select
12 Dimming
VDIM 0–10V
13 Housing Color
Bronze
B Black
W White
5 Shape
R Rectangular
C Circular
6 Style
1 Non-Cutoff
2 Full-Cutoff
8 Mounting
UNV Universal
9 CRI
8 >80
9 >90
2 Fixture Type
F Flood
WP Wallpack
Keystone Technologies • Philadelphia PA • Phone (800) 464-2680 • www.keystonetech.com Specifications subject to change. Last revised on 02.24.21

Page 5 of 5 ends

KT-FLED35-R1A-UNV-8CSB-VDIM
COMPACT 35W GENERAL-PURPOSE LED FLOOD LIGHT
1 Keystone Technologies
2 Fixture Type
3 LED Lamp
4 Max Wattage
5 Shape
6 Style
7 Distribution
8 Mounting
9 CRI
10 Color
11 Color Select Designation
12 Dimming
13 Housing Color

CATALOG NUMBER BREAKDOWN
KT-FLED35-R1A-UNV-8CSB-VDIM
1 2 3 4 5 6 7 8 9 10 11 12 13

ORDERING INFORMATION
CATALOG NUMBER PACK QTY. EASY CODE UPC
KT-FLED35-R1A-UNV-8CSB-VDIM 1 DND-10 843654128962
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 4 Pin Universal PL Lamp Retrofits - Type A/B
MODEL VOLTAGE WATTAGE LUMENS* LPW* REPLACES BASE CCT CRI* THD* PF* R9* Duv* DIMMABLE LED-7324-27K-G2 1200 110 2700K >80 N/A >.9 10 0.0002
LED-7324-35K-G2 1200 110 3500K >80 N/A >.9 22 -0.002
LED-7324-40K-G2 1200 110 4000K >80 N/A >.9 25 0.0007
LED-7320-27K-G2 900 90 2700K >80 N/A >.9 19 -0.0007
LED-7320-35K-G2 1000 100 3500K >80 N/A >.9 6 0.0014
LED-7320-40K-G2 1000 100 4000K >80 N/A >.9 6 0.0005
LED-7318-27A 837 95 2700K >80 N/A >.9 8 N/A
LED-7318-35A 1157 95 3500K >80 N/A >.9 12 N/A
LED-7318-40A 1198 95 4000K >80 N/A >.9 12 N/A

MODEL CARTON

QUANTITY
LED-7324-G2 24
LED-7320-G2 24
LED-7318A 50
Width 6
Height 6 N/A
N/A
Product Specifications Sheet
TECHNICAL SPECIFICATIONS - 120-277V or Compatible Ballast - ALL MODELS cUlus

LIGHT DISTRIBUTION
Packaging
120-277V
11W
10W
12W
G24q
or
GX24q
26W 4 Pin
120°
Omni-Directional / 360°
120°
Yes - on a
dimmable ballast.

See Note *
Yes - on a
dimmable ballast.

See Note *
No

SHIPPER CTN WT

5.47 x 1.374 in. 0.4 Lbs. 0.3 lbs/.13 kg. 12.5 X 15.6 X 5.1 in./ 320 X 395 X 130 mm.
4 lbs./1.8 kg.

PRODUCT DIMENSION PRODUCT WEIGHT UNIT CARTON DIMENSION UNIT CTN WT SHIPPER CARTON DIMENSION 20 lb./9.1 kg.

6.97 x 1.374 in. 0.4 Lbs. 0.3 lbs/.13 kg. 10.5 X 7.25 X 7.25 in./ 266 X 184 X 184 mm.
4 lbs./1.8 kg.

3.78 X 2.99 in. 0.4 Lbs. 3.2 X 3.2 X 4.7 in./ 81 X 81 X 119 mm. 0.4 lbs./.18 kg. 18.1 X 9.44 X 6.88 in./ 460 X 240 X 175 mm.

ENERGY SAVINGS vs. HID Mounting Orientation
LED Lamp
Power (watts)
11 BASE DOWN BASE UP HORIZONTAL
Annual Energy Savings $10.62
IN-SITU TEMP MEASUREMENT/L70
LED TEMPERATURE*

18.9 OPERATING

TEMPERATURE
0°F to +85°F / -17°C to +30°C
PL Lamp
Power (watts)
26 PL Ballast
Power (watts)
4 APPROVED APPROVED APPROVED
Recommended
Mininum
Fixture Size

THERMAL SPECIFICATIONS
Total power
Savings (watts)
Lifetime Energy Savings over
50,000 hrs)
$103.95 Volume
(Cu. Cm.) 216
L70 LED LUMEN MAINTAINENCE*
* FROM ISTMT REPORT AT 25°C
Models
LED-7324-XXK-G2, 2700K, 3500K & 4000K CCT
LED-7320-XXK-G2, 2700K, 3500K & 4000K CCT
LED-7318-XXA, 2700K, 3500K & 4000K CCT
Description
Light Efficient Design's 4 Pin PL Lamp Retrofit Lamps replace CFL lamps up to 26W.

Unique lamp designs closely match existing PL lamp to deliver optimum light distribution.

Type A/B Universal Driver- Works on Electronic Ballast or 120-277V Line Voltage.

Features
• 10W - 12W LED Replaces up to 26W CFL Lamps
• Up to 1,200 lumen output and 106 LPW efficacy
• Compatible with G24q or GX24q PL/CFL sockets
• Suitable for damp environments and semi-enclosed recessed fixtures or equivalent • 50,000 hour rated LED life
• 5 Year Limited Warranty - see website for details
• Insect/dust resistant housing
LED-7318
LED-7320
LED-7324
Please see instruction sheet for a list of compatible ballasts.

LIGHT EFFICIENT DESIGN ■ 188 S. NORTHWEST HIGHWAY ■ CARY, IL 60013 ■ (847) 380-3540 ■ www.led-llc.com For use with the LED-7318-XXA,
the LED-7319 Socket extender will
add about 1.7" to the length of the lamp. This may
be useful to properly position the lamp in a deeper
fixture.
* When using dimmable PL lamps on dimmable ballasts, it is necessary for the installer to verify the proper operation of the lamps. Due to the interaction of the Electronic Ballasts and LED PL lamps, the response may be non-linear and the lamps may flash or flicker at medium to low dimming levels.

These lamps are NOT dimmable on line voltage. When operated on line voltage they will operate at full power only.
7/24/2018
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 SYLVANIA Luminaires
UltraLED™ Selectable Downlights
www.sylvania.com/luminaires
Application
The SYLVANIA UltraLED Selectable Downlights are offered in 5/6", 6", and 8" sizes and provide high performing light optimized for both new construction and retrofit applications where pin based compact fluorescent lamps have previously been used. The installation is done quickly and easily in most standard frames. The lumen and CCT selectable switches
allow for customizable light replacing up to two 26W compact fluorescent lamps and offering up to 52% energy savings when compared to traditional technologies.

Benefits and Features
— Lumen and CCT selectable light enabled through the two switches located on the base of the product
— This product is available in lumen selectable only versions – enabled through the one switch located on the base of the product
— ENERGY STAR® listed to maximize rebate opportunities
— Available in 5/6", 6" (lumen and lumen and CCT versions), and 8" sizes (lumen selectable versions only)
— Up to 93 LPW
— 2700K, 3000K, 3500K, 4000K, and 5000K and
selectable K color temperature
— CRI >90
— Lumen Selectable offered in 9 or 12 watt, 14.5 or 18 watt, and 17 or 25 watt versions
— Lumen and CCT Selectable offered in 9 or 12 watt or 14.5 or 18 watt versions
— CCT Selectable and EMBB Ready offered in 9, 12, 14, 18, 23, 32 or 57 watt versions
— Energy savings up to 52%
Electrical
— 120-277Vac
— Power Factor >90%
— THD <20%
— 0-10V dimmable
— Phase-cut dimmable (9W CCT Selectable/EMBB Ready only) Rated Life
— 50,000 hours (L70)
Warranty
— 5-year (please see LEDLUM001)
LEDLUM055R3 10-20
Item #
Type
Project
Notes
Date
C US

ETL CLASSIFIED
Wattage Comparison
Traditional LED System Energy
Source Wattage Savings
13 or 18W CFL 9 or 12W 30 or 33%
23 or 32W CFL 14.5 or 18W 37 or 44%
32W or 2x26W CFL 17 or 25W 47 or 52%
Certifications and Listings
— cETLus
— ENERGY STAR
— RoHS
— FCC
Installation
— Installation performed as a stand-alone kit (without frame) is recommended for hard ceiling. Installation of a recessed incandescent frame is recommended for tiled ceiling
application for proper support of the retrofit kit.

Ambient Operating Range
— -4°F to +104°F (-20°C to +40°C)
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 Ordering Guide
One Switch (Lumen Selectable)
RT SL XX R 1A XXXXXX U D 9 XX
RT =
Retrofit
Downlight
SL =
Selectable Lumen
Size
56 = 5/6"
6 = 6"
8 = 8"
Shape
R = Round
Generation Light Output
700900 = 700
or 900 lumens
12001500 = 1200
or 1500 lumens
15002000 = 1500
or 2000 lumens
Voltage
U = 120-277V
Dimming
D = 0-10V
CRI
9 = >90
CCT
27 = 2700K
30 = 3000K
35 = 3500K
40 = 4000K
50 = 5000K
Two Switch (Lumen and CCT Selectable)
RT SD XX 1A XXXX U D 9 303540
RT =
Retrofit
Downlight
SD =
Dual Selectable
(Lumen and CCT)
Size
56 = 5/6"
6 = 6"
Generation Light Output
79 = 700 or 900 lumens
1215 = 1200
or 1500 lumens
Voltage
U = 120-277V
Dimming
D = 0-10V
CRI
9 = >90
CCT
303540 = 3000K, 3500K
or 4000K
CCT Selectable and EMBB Ready
LED RT XX / R 3C / XXXX U D 9 SC8
LED RT =
Retrofit
Downlight
Size
56 = 5/6"
6 = 6"
8 = 8"
Shape
R = Round
Generation
3C = Generation 3C
Light Output
700 = 700 lumens
900 = 900 lumens
1200 = 1200 lumens
1500 = 1500 lumens
2000 = 2000 lumens
3000 = 3000 lumens
5000 = 5000 lumens
Voltage
U = 120-277V
Dimming
D = 0-10V
CRI
9 = >90
Selectable CCT
SC8 = 3000K,
3500K or 4000K
or 5000K
Ordering Information
Item
Number
Ordering
Abbreviation
Power
(W)
Input
Voltage Dimming CRI
Color
Temp
(CCT)
Total
Fixture
Lumens
Lumens
per Watt
ENERGY
STAR®
Listed MTO*
Lumen Selectable Only
60742 RTSL56R1A700900UD927 9 or 12 120-277 0-10V 90 2700K 700 or 900 75 Yes – 60743 RTSL56R1A700900UD930 9 or 12 120-277 0-10V 90 3000K 700 or 900 75 Yes – 60744 RTSL56R1A700900UD935 9 or 12 120-277 0-10V 90 3500K 700 or 900 75 Yes – 60745 RTSL56R1A700900UD940 9 or 12 120-277 0-10V 90 4000K 700 or 900 75 Yes – 60746 RTSL56R1A700900UD950 9 or 12 120-277 0-10V 90 5000K 700 or 900 75 Yes MTO 60747 RTSL6R1A12001500UD927 14.5 or 18 120-277 0-10V 90 2700K 1200 or 1500 83 Yes MTO 60748 RTSL6R1A12001500UD930 14.5 or 18 120-277 0-10V 90 3000K 1200 or 1500 83 Yes MTO 60749 RTSL6R1A12001500UD935 14.5 or 18 120-277 0-10V 90 3500K 1200 or 1500 83 Yes – 60750 RTSL6R1A12001500UD940 14.5 or 18 120-277 0-10V 90 4000K 1200 or 1500 83 Yes – 60751 RTSL6R1A12001500UD950 14.5 or 18 120-277 0-10V 90 5000K 1200 or 1500 83 Yes – 60752 RTSL8R1A15002000UD927 17 or 25 120-277 0-10V 90 2700K 1500 or 2000 80 Yes MTO 60753 RTSL8R1A15002000UD930 17 or 25 120-277 0-10V 90 3000K 1500 or 2000 80 Yes – 60754 RTSL8R1A15002000UD935 17 or 25 120-277 0-10V 90 3500K 1500 or 2000 80 Yes – 60755 RTSL8R1A15002000UD940 17 or 25 120-277 0-10V 90 4000K 1500 or 2000 80 Yes – 60756 RTSL8R1A15002000UD950 17 or 25 120-277 0-10V 90 5000K 1500 or 2000 80 Yes – Lumen and CCT Selectable
60814 RTSD561A79UD9303540 9 or 12 120-277 0-10V 90 3000, 3500 or 4000K 700 or 900 75 Yes – 60815 RTSD61A1215UD9303540 14.5 or 18 120-277 0-10V 90 3000, 3500 or 4000K 1200 or 1500 83 Yes – CCT Selectable and EMBB Ready
65472 LEDRT56/R3C/700ST/9SC8 9 120 Phase-cut 90 3000, 3500, 4000 or 5000K 700 77 Yes – 65473 LEDRT56/R3C/700UD/9SC8 9 120-277 0-10V 90 3000, 3500, 4000 or 5000K 700 77 Yes – 65474 LEDRT56/R3C/900UD/9SC8 12 120-277 0-10V 90 3000, 3500, 4000 or 5000K 900 75 Yes – 65475 LEDRT6/R3C/1200UD/9SC8 14 120-277 0-10V 90 3000, 3500, 4000 or 5000K 1200 88 Yes – 65476 LEDRT6/R3C/1500UD/9SC8 18 120-277 0-10V 90 3000, 3500, 4000 or 5000K 1500 88 Yes – 65477 LEDRT8/R3C/900UD/9SC8 12 120-277 0-10V 90 3000, 3500, 4000 or 5000K 900 86 Yes – 65478 LEDRT8/R3C/1500UD/9SC8 18 120-277 0-10V 90 3000, 3500, 4000 or 5000K 1500 86 Yes – 65479 LEDRT8/R3C/2000UD/9SC8 23 120-277 0-10V 90 3000, 3500, 4000 or 5000K 2000 86 Yes – 65480 LEDRT8/R3C/3000UD/9SC8 32 120-277 0-10V 90 3000, 3500, 4000 or 5000K 3000 93 Yes – 65481 LEDRT8/R3C/5000UD/9SC8 57 120-277 0-10V 90 3000, 3500, 4000 or 5000K 5000 87 Yes – *Made To Order
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 700/900lm 1500/2000lm One Switch 1200/1500lm Two Switch Spacing to Mounting Height Ratio
Spacing Criterion (0-180) 1.12
Spacing Criterion (90-270) 1.14
Spacing Criterion (Diagonal) 1.22
Spacing to Mounting Height Ratio
Spacing Criterion (0-180) 1.12
Spacing Criterion (90-270) 1.14
Spacing Criterion (Diagonal) 1.2
Spacing to Mounting Height Ratio
Spacing Criterion (0-180) 1.18
Spacing Criterion (90-270) 1.2
Spacing Criterion (Diagonal) 1.26
Illuminance at a Distance
Distance to
Illuminated
Plane (feet)
Footcandles
Beam Center
Footcandles
Beam Edge
Beam
Diameter
(feet)
2 119.7 fc 22.9 fc 3.8
4 29.9 fc 5.7 fc 7.6
6 13.3 fc 2.5 fc 11.4
8 7.5 fc 1.4 fc 15.2
10 4.8 fc 0.9 fc 19
12 3.3 fc 0.6 fc 22.8
Illuminance at a Distance
Distance to
Illuminated
Plane (feet)
Footcandles
Beam Center
Footcandles
Beam Edge
Beam
Diameter
(feet)
2 196.6 fc 38 fc 3.8
4 49.2 fc 9.5 fc 7.5
6 21.8 fc 4.2 fc 11.3
8 12.3 fc 2.4 fc 15.1
10 7.9 fc 1.5 fc 18.8
12 5.5 fc 1.1 fc 22.6
Illuminance at a Distance
Distance to
Illuminated
Plane (feet)
Footcandles
Beam Center
Footcandles
Beam Edge
Beam
Diameter
(feet)
2 250.5 fc 42 fc 4.1
4 62.6 fc 10.5 fc 8.3
6 27.8 fc 4.7 fc 12.4
8 15.7 fc 2.6 fc 16.6
10 10 fc 1.7 fc 20.7
12 7 fc 1.2 fc 24.9
Luminous Intensity Distribution Diagrams
Photometrics
Zonal Lumen Distribution
Zone Lumens % Retrofit Kit
0-20 170 18
0-30 350 38
0-40 549 59
0-60 838 91
0-80 919 99
0-90 925 100
10-90 880 95
20-40 379 41
20-50 551 60
40-70 348 38
60-80 81 9
70-80 22 2
80-90 6 1
0-180 925 100
Zonal Lumen Distribution
Zone Lumens % Retrofit Kit
0-20 279 18
0-30 572 38
0-40 894 59
0-60 1370 90
0-80 1508 99
0-90 1518 100
10-90 1444 95
20-40 615 41
20-50 897 59
40-70 577 38
60-80 138 9
70-80 37 2
80-90 10 1
0-180 1518 100
Zonal Lumen Distribution
Zone Lumens % Retrofit Kit
0-20 360 18
0-30 749 37
0-40 1198 59
0-60 1857 91
0-80 2020 99
0-90 2034 100
10-90 1940 95
20-40 838 41
20-50 1242 61
40-70 772 38
60-80 163 8
70-80 50 3
80-90 14 1
0-180 2034 100
0 30
60 90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cd
C0/180,85.4
C90/270,85.1
AVERAGE BEAM ANGLE(50%):85.3 DEG
0 80
160
240
320
0 30
60 90
120
150
-/+180
-150
-120
-90 -90
-60
-30
UNIT:cd
C0/180,89.4
C90/270,89.3
AVERAGE BEAM ANGLE(50%):89.3 DEG
0 160
320
480
640
0 30
60 90
120
150
-/+180
-150
-120
-60
-30
UNIT:cd
C0/180,85.1
C90/270,85.1
AVERAGE BEAM ANGLE(50%):85.1 DEG
0 130
260
390
520
400 800 650
0 30
60 90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cd
C0/180,85.4
C90/270,85.1
AVERAGE BEAM ANGLE(50%):85.3 DEG
0 80
160
240
320
0 30
60 90
120
150
-/+180
-150
-120
-90 -90
-60
-30
UNIT:cd
C0/180,89.4
C90/270,89.3
AVERAGE BEAM ANGLE(50%):89.3 DEG
0 160
320
480
640
0 30
60 90
120
150
-/+180
-150
-120
-60
-30
UNIT:cd
C0/180,85.1
C90/270,85.1
AVERAGE BEAM ANGLE(50%):85.1 DEG
0 130
260
390
520
400 800 650
0 30
60 90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cd
C0/180,85.4
C90/270,85.1
AVERAGE BEAM ANGLE(50%):85.3 DEG
0 80
160
240
320
0 30
60 90
120
150
-/+180
-150
-120
-90 -90
-60
-30
UNIT:cd
C0/180,89.4
C90/270,89.3
AVERAGE BEAM ANGLE(50%):89.3 DEG
0 160
320
480
640
0 30
60 90
120
150
-/+180
-150
-120
-60
-30
UNIT:cd
C0/180,85.1
C90/270,85.1
AVERAGE BEAM ANGLE(50%):85.1 DEG
0 130
260
390
520
400 800 650
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 Physical Information
RT6 700-900 One Switch
RT6 700-900 Two Switch
ø187.00 [7.37]

94.00 [3.70] 63.00
[2.48]
ø187.00 [7.37]

94.00 [3.70] 63.00
[2.48]
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 Physical Information (continued)
RT6 1200-1500 One Switch
RT6 1200-1500 Two Switch
ø187.00 [7.37]
109.48
[4.31] 77.48
[3.05]
ø187.00 [7.37]
109.48
[4.31] 77.48
[3.05]
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 ø240.00 [9.46]
127.97

95.97 [5.04]
[3.78]
Physical Information (continued)
RT6 1500-2000 One Switch
75082 71708
75095
Accessories
Item Number Ordering Abbreviation Item Decsription
Trim Rings
75095 RT/5/6/TRIM/DKBZ Dark bronze trim ring (5/6")
75097 RT/5/6/TRIM/BLK Black trim ring (5/6")
75098 RT/5/6/TRIM/ORBZ Bronze trim ring (5/6")
75099 RT/5/6/TRIM/SN Satin nickel trim ring (5/6")
Trim Ring Extender
75082 RT6/8/TRIMEXT Trim extender for 8" cans
Rough In Frame
71708 LED/RT6HO/FRAME 6" recessed rough-in frame
75097 75098

8.82”
(224mm)

6.73”
(171mm)
75099 and 75093
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 /sylvania /sylvania
© 2020 LEDVANCE LLC

LEDVANCE LLC
200 Ballardvale Street
Wilmington, MA 01887 USA
Phone 1-800-LIGHTBULB (1-800-544-4828)
www.sylvania.com
SYLVANIA and LEDVANCE are registered trademarks.

All other trademarks are those of their respective owners.

Licensee of product trademark SYLVANIA in general lighting.

Specifications subject to change without notice.

Name:

Email:

Phone:

Additional Specifications
— Compatible with 0-10V Dimmers.
— Suitable for dry, damp, and wet indoor or outdoor locations. — Not intended for use with emergency light fixtures or exit lights. — Standard 5-year luminaire warranty (LEDLUM001).

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 Copyright © 2014 ESPEN Technology Inc. All Rights Reserved Espen Technology Inc. | 12257 Florence Ave. | Santa Fe Springs, CA 90670 Toll Free: (866) 933-7736 | Tel.: (562) 529-2938 | Fax: (562) 529-2978 | Email: [email protected] Features & Benefits
Internal Driver
Smooth, Consistent Light
UL for Safety
No UV, No Mercury
Long Life
High CRI
Instant on, no delay or warm up time
Convenient and quick installation
Utilizes non-shunted(rapid start) sockets
Compatible with controls and sensors
Works in cold temperature applications
5 Year Warranty
Commercial Grade LED FT Lamp
Specification Data
Model No. Replace Lamp Wattage Input Voltage CCT Initial Lumens CRI Lamp Efficacy Life LT40W/835-ID FT40W/FT55W 18 120-277 3500 1800 83 100 50000 LT40W/840-ID FT40W/FT55W 18 120-277 4000 1800 83 100 50000 LT40W/850-ID FT40W/FT55W 18 120-277 5000 1800 83 100 50000 Wiring diagram
LT series Overall Length (cm) Base face to top
(cm)
LT40 54.00 49.30
LT36 42.10 37.40
LT24 32.60 27.80
LT18 23.10 18.30
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 60W
9W REPLACES
Inc.

TITANIUM LED SERIES TITANIUM LED SERIES 2.0
80% Energy Savings
$151 Savings
per lamp*
A19 9W DIM.

WARRANTY
YR
3 25,000 H
PRO
89 82
Exceptional efficacy 89 LPW in Soft White
40% more energy savings than CFL
Comfortable warm diffused light
Natural A-lamp shape fits all applications
Ideal for lamps with shades
Suitable for use in totally enclosed fixtures
www.greencreative.com / [email protected] - Tel / Fax: (866) 774-5433 - / GClightingLED / GREEN CREATIVE A19 PRODUCT FEATURES

ENCLOSED

DIMMABLE
60W Equivalent Efficacies
90 80
70 60
50 40
30 20
10 GREEN

CREATIVE
OTHER
TIER 1 LED
INC.

LPW

ENERGY CFL
STAR 2.0

ENCLOSED
This A19 is suitable for use in totally enclosed fixtures and capable of operating in a broad range of applications. Whether it is installed in fully enclosed flushmounts or sconces, this lamp’s advanced thermal design ensures optimal performance over the course of its lifetime.

Suitable for Enclosed Fixtures
TM 21 IES
At 89 LPW, this lamp’s efficacy is higher than the Tier 1 LED A19 60W replacement industry average and exceeds new ENERGY STAR 2.0 requirements. This energy-saving performance makes this lamp a smart retrofit choice for incandescent and CFL bulbs.

Exceptional Efficacy
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 General Lighting Downlighting Uplighting

APPLICATIONS
** Suitable for use in totally enclosed fixtures
*** Suitable for damp locations. Not for use where directly exposed to weather or water * Savings per lamp based on $0.11 / kw energy cost, 12 hrs / day lamp usage, $2 incandescent with 1000-hr lifetime, $16 LED with 25,000-hr lifetime

SPECIFICATIONS
Product
Model
Type
Base
Power (W)
Voltage - Frequency
Color Temp. (ANSI)
CRI (Ra) (typ.)
Typical lumens (lm)
Efficacy (LPW)
Beam Angle
Dimmable
Power Factor
Rated Lifetime - L70 (hrs.)
Dia. x MOL
Weight (lb. / g)
A19
E26
9 120V 60Hz
Soft White 2700K
82 800
89 240°
Yes**

0.9 25,000

2.36"x4.41" (60x112mm)

0.10lb. / 45g
A19
E26
9 120V 60Hz
Warm White 3000K
82 820
91 240°
Yes**

0.9 25,000

2.36"x4.41" (60x112mm)

0.10lb. / 45g
A19
E26
9 120V 60Hz
Cool White 4000K
82 860
96 240°
Yes**

0.9 25,000

2.36"x4.41" (60x112mm)

0.10lb. / 45g
97781
9A19DIM/830
97782
9A19DIM/840
97780
9A19DIM/827
A19 9W DIM. TITANIUM LED SERIES
Ref.#:DS170-A19-9W-230217
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 BR30 9W DIM.

FEATURES
ENERGY STAR certified
65W incandescent replacement
Energy efficient
Environmentally friendly
Providing a comfortable diffused level of light
Smooth dimming with existing installations
Suitable for use in totally enclosed fixtures
Suitable for use in damp locations
Operating temperature: -4°F / -20°C to +95°F / +35°C
Rated Lifetime (L70): 25,000hrs
3 years limited warranty
Shatterproof
•
•
•
•
•
•
•
•
•
•
•
•

SPECIFICATIONS
9BR30DIM/827
9BR30DIM/830
9BR30DIM/840
98461
98462
98463
* This lamp might not be compatible with all dimmers. Please visit www.greencreative.com for compatibility information. 2700K
3000K
4000K
E26
E26
E26

0.9 0.9

0.9 82
82 82
Yes*
Yes*
Yes*
25,000
25,000
25,000
120V 60Hz
120V 60Hz
120V 60Hz
650
650
650
72 72
72 120°
120°
120°

DIMENSION & WEIGHT
Base E26

5.27” (134mm)

3.74” (95mm)

0.19lb/87g
M.O.L
Dia.

Weight
www.greencreative.com / [email protected] - Tel / Fax: (866) 774-5433 - / GREENCREATIVELED / GClightingLED / GREEN CREATIVE DS375-BR30-9W-160119
Product Model CCT Base Lumens Power
Factor
Beam
Angle
Efficacy
(LPW) Input Voltage CRI Dim. Lifetime(L70)
Dia.

M.O.L
Project Name:

Part Number: Date:

Type:

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 KT-LED7T8-24GC-840-DX2
T8 LED LAMP
7W T8 LED | 4000K | >83 CRI | High Efficiency | Single or Double-ended Wiring

DESCRIPTION
• Replacement for Conventional Fluorescent Lamp
• Single or Double-Ended Wiring
• 50,000+ Hour Lifetime
• Approximately 40% More Energy Efficient that Standard F32T8 Lamps • Environmentally Friendly: No Mercury Used
• Instant Startup
• Frosted Lens Eliminates Pixelation
• UL Classified
• Operating Temperature: -20ºC/-4ºF to 45ºC/113ºF
• Integral Driver (Isolated), Eliminates the Need
for External Driver or Ballast
• 110+ Lumens per Watt
• Improved Lamp Durability with Shatterproof Coated Glass • ETL Sanitation Listed NSF/ANSI Standard 2 - Food Equipment

PRODUCT FEATURES
LAMP TYPE: Linear
BULB TYPE: T8 LED
BASE TYPE: G13 (Medium Bi-Pin)
WATTAGE: 7W
COLOR TEMPERATURE: 4000K
COLOR RENDERING INDEX (CRI): >83
WARRANTY: 5 Years

Page 1 of 3 ends

OPERATING SPECIFICATIONS

RATED LIFE
L70 (Hours) 50,000

PHOTOMETRIC CHARACTERISTICS
Color Temperature (CCT) 4000K
Luminous Flux 900 lm
Color Rendering Index (CRI) >83
Efficacy 129 lm/W
Beam Angle 240º
Visible Light Area 325º

ELECTRICAL CHARACTERISTICS
Input Voltage Power Consumption Power Factor Input Current 120-277Vac 7W >0.9 0.06A @ 120V

0.03A @ 277V

60.8 121.6
182.4
243.2
304.6
2 1

SPECTRAL DISTRIBUTION

POLAR CANDELA DISTRIBUTION
Maximum Candela = 1248.55
Located at Horizontal Angle = 0,
Vertical Angle 0

1. Violet Vertical Plane through Horizontal
Angles (90-270)

2. Green Vertical Plane through Horizontal
Angles (0-180)
Wavelength (nm)
Flux (W/nm)
350 425 500 575 650 725 800

1.0 0.8

0.6 0.4

0.2 0.0
Flux (W/nm)
Keystone Technologies • Philadelphia, PA • Phone (800) 464-2680 • www.keystonelamp.com Specifications subject to change. Last revised on November 15, 2019 1:50 PM DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 KT-LED7T8-24GC-840-DX2
T8 LED LAMP

Page 2 of 3 ends

Connect wires directly to these terminals
Typical Non-Shunted Lampholder
CAUTION: For Singleended wiring use only
non-shunted lampholders.

For Single-ended wiring, do not
install product in a fixture with
shunted lampholders (found in
all fixtures using instant start ballasts). If the current lampholders are shunted, remove them and
replace them with non-shunted
lampholders. Make new connections directly to terminals as indicated above.

Keystone can provide any style
replacement lampholders.

Call us at 800-464-2680.

SINGLE-ENDED WIRING DIAGRAM
Figure A Typical Ballast Configurations:

PROGAM START
LINE

NEUTRAL
YELLOW

YELLOW RED
RED
BLUE
BLUE
LAMP
LAMP

BALLAST

PREHEAT WITH STARTER

LINE BLACK

BALLAST
LAMP
S

INSTANT START
LINE

NEUTRAL
BLUE
BLUE
RED
LAMP
LAMP

BALLAST

2. Re-wire fixture as shown below.

1. Cut all existing connections to ballast as shown below and remove ballast. See Figure A for typical ballast configurations. Note: Single-ended wiring requires non-shunted lampholders.

CAUTION: INSTANT START BALLASTS
HAVE SHUNTED LAMPHOLDERS.

DOUBLE-ENDED WIRING DIAGRAM

POWER SOURCE

LINE NEUTRAL

NEUTRAL
LINE
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
No Live
Connection
Side A
Side B
Side A
Side B
Side A Side A
Side B Side B

1. Cut all existing connections to ballast as shown below and remove ballast. See Figure A above for typical ballast configurations.

LINE NEUTRAL
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Side A
Side B
Side A
Side B
Side A Side A
Side B Side B
Shunted Lampholders

LINE NEUTRAL
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Side A
Side B
Side A
Side B
Side A Side A
Side B Side B
Nonshunted Lampholders

2. Re-wire fixture as shown below. For Double-ended wiring, use either shunted or nonshunted lampholders.

Note: There should not be any exposed wires at the end of installation.

Keystone Technologies • Philadelphia, PA • Phone (800) 464-2680 • www.keystonelamp.com Specifications subject to change. Last revised on November 15, 2019 1:50 PM DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8

ORDERING INFORMATION
ORDER CODE PACKAGING STYLE PACK QTY. ITEM STATUS
KT-LED7T8-24GC-840-DX2-CP Carton Pack (Egg Crate Packaging) 25 Quick Ship KT-LED7T8-24GC-840-DX2
T8 LED LAMP

Page 3 of 3 ends

PHYSICAL CHARACTERISTICS

LAMP DIMENSIONS
A (Illuminated Length) 20.96”
B (Body Length) 23.19”
C (Diameter) 1.10”
NOMINAL LENGTH: 24” BASE TYPE: G13 (Medium Bi-Pin)
C
B
A
Keystone Technologies • Philadelphia, PA • Phone (800) 464-2680 • www.keystonelamp.com Specifications subject to change. Last revised on November 15, 2019 1:50 PM

CATALOG NUMBER BREAKDOWN
1 Keystone Technologies
2 LED Lamp
3 Wattage
4 Lamp Type
5 Nominal Length (Inches)
6 Shatter-Proof Coated Glass
7 800 Series
8 Color Temperature
9 Single or Double-Ended Wiring
10 Packaging Style
KT-LED7T8-24GC-840-DX2-CP
1 2 3 4 5 6 7 8 9 10
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8

DESCRIPTION
18W T8 U-Bend LED | 4000K | >80 CRI | High Efficiency
• Replacement for Conventional Fluorescent Lamp
• UL Classified; Listed on DLC Qualified Product List
• 50,000+ Hour Lifetime
• Approximately 40% More Energy Efficient than Standard F32T8 Lamps • Environmentally Friendly: No Mercury Used
• Integral Driver (Isolated) Eliminates the Need for an External Ballast or Driver • Instant Startup
• Frosted Lens Eliminates Pixelation
• Operating Temperature: -20ºC/-4ºF to 45ºC/113ºF
• 110+ Lumens per Watt (Bare Lamp Efficacy)
• Suitable for Dry and Damp Locations
• Improved Lamp Durability with Shatterproof Coated Glass • NSF Listed: NSF/ANSI Standard 2 - Food Equipment

PRODUCT FEATURES

Page 1 of 2 ends

Keystone Technologies • 1390 Welsh Road, North Wales, PA 19454 • Phone (800) 464-2680 • Fax (888) 966-0556 • www.keystonetech.com Specifications subject to change. Last revised on 9.12.16

POLAR CANDELA DISTRIBUTION
Located at Horizontal Angle = 0,
Vertical Angle 0

1. Violet Vertical Plane through Horizontal
Angles (90-270)

2. Green Vertical Plane through Horizontal
Angles (0-180)
LAMP TYPE: U-Bend
BULB TYPE: T8 LED
BASE TYPE: G13 (Medium Bi-Pin)
WATTAGE: 18W
COLOR TEMPERATURE: 4000K
COLOR RENDERING INDEX (CRI): >80
WARRANTY: 5 Years

OPERATING SPECIFICATIONS

RATED LIFE
L70 (Hours) 50,000

ELECTRICAL AND PERFORMANCE CHARACTERISTICS
Input Voltage CRI Bare Lamp Wattage Nominal Lamp Lumens Beam Angle Nominal Bare Lamp Efficacy Power Factor Max. THD 120-277V >80 18W 2150 220º 119 lm/W >0.9 20%
Beam Angle: 220º
Visible Light Area: 325º
KT-LED18T8-U6GC-840-D
U-BEND T8 LED LAMP
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8

ORDERING INFORMATION
ORDER CODE PACKAGING STYLE PACK QTY. ITEM STATUS
KT-LED18T8-U6GC-840-D-CP Carton Pack (Egg Crate Packaging) 12 Quick Ship Keystone Technologies • 1390 Welsh Road, North Wales, PA 19454 • Phone (800) 464-2680 • Fax (888) 966-0556 • www.keystonetech.com Specifications subject to change. Last revised on 9.12.16 KT-LED18T8-U6GC-840-D
U-BEND T8 LED LAMP

Page 2 of 2 ends

CATALOG NUMBER BREAKDOWN
KT-LED18T8-U6GC-840-D-CP
Keystone
Technologies
LED Lamp Nominal
Size
Lamp
Type
800
Series
Shatterproof
Coated Glass
Wattage Color
Temp.

Packaging
Style
Direct
Drive
Series

PHYSICAL CHARACTERISTICS

LAMP DIMENSIONS
A (Illuminated Length) 20.20”
B (Body Length) 22.25”
C (Diameter) 1.00”
D (Width) 6.00”
Nominal Length 6” U-Bend
Base Type G13 (Medium Bi-Pin)
C
D
B
A
LINE

NEUTRAL

NO LIVE

CONNECTION
Connect wires directly to these terminals
Typical Non-Shunted Lampholder
CAUTION:

Use only non-shunted lampholders.

Do not install product in a fixture with
shunted lampholders (found in all fixtures
using instant start ballasts). If the current
lampholders are shunted, remove them and
replace them with non-shunted lampholders.

Make new connections directly to terminals
as indicated above.

Keystone can provide any style replacement
lampholders. Call us at 800-464-2680.

WIRING
Re-wire fixture as show below.

POWER SOURCE

LINE NEUTRAL

NO LIVE

CONNECTION
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 KT-LED12T8-36GC-840-DX2
T8 LED LAMP
12W T8 LED | 4000K | >83 CRI | High Efficiency | Single or Double-ended Wiring

DESCRIPTION
• Replacement for Conventional Fluorescent Lamp
• Single or Double-Ended Wiring
• 50,000+ Hour Lifetime
• Approximately 40% More Energy Efficient that Standard F32T8 Lamps • Environmentally Friendly: No Mercury Used
• Instant Startup
• Frosted Lens Eliminates Pixelation
• UL Classified
• Operating Temperature: -20ºC/-4ºF to 45ºC/113ºF
• Integral Driver (Isolated), Eliminates the Need
for External Driver or Ballast
• 110+ Lumens per Watt
• Improved Lamp Durability with Shatterproof Coated Glass • ETL Sanitation Listed NSF/ANSI Standard 2 - Food Equipment

PRODUCT FEATURES
LAMP TYPE: Linear
BULB TYPE: T8 LED
BASE TYPE: G13 (Medium Bi-Pin)
WATTAGE: 12W
COLOR TEMPERATURE: 4000K
COLOR RENDERING INDEX (CRI): >83
WARRANTY: 5 Years

Page 1 of 3 ends

OPERATING SPECIFICATIONS

RATED LIFE
L70 (Hours) 50,000

PHOTOMETRIC CHARACTERISTICS
Color Temperature (CCT) 4000K
Luminous Flux 1400 lm
Color Rendering Index (CRI) >83
Efficacy 117 lm/W
Beam Angle 240º
Visible Light Area 325º

ELECTRICAL CHARACTERISTICS
Input Voltage Power Consumption Power Factor Input Current 120-277Vac 12W >0.9 0.10A @ 120V

0.04A @ 277V
243.2
304.6
2 1

60.8 121.6
182.4

POLAR CANDELA DISTRIBUTION
Maximum Candela = 1248.55
Located at Horizontal Angle = 0,
Vertical Angle 0

1. Violet Vertical Plane through Horizontal
Angles (90-270)

2. Green Vertical Plane through Horizontal
Angles (0-180)
Keystone Technologies • Philadelphia, PA • Phone (800) 464-2680 • www.keystonetech.com Specifications subject to change. Last revised on 12.12.19

SINGLE- OR DOUBLE-ENDED LINE VOLTAGE LED TUBES
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 KT-LED12T8-36GC-840-DX2
T8 LED LAMP

Page 2 of 3 ends

Connect wires directly to these terminals
Typical Non-Shunted Lampholder
CAUTION: For Singleended wiring use only
non-shunted lampholders.

For Single-ended wiring, do not
install product in a fixture with
shunted lampholders (found in
all fixtures using instant start ballasts). If the current lampholders are shunted, remove them and
replace them with non-shunted
lampholders. Make new connections directly to terminals as indicated above.

Keystone can provide any style
replacement lampholders.

Call us at 800-464-2680.

SINGLE-ENDED WIRING DIAGRAM
Figure A Typical Ballast Configurations:

PROGAM START
LINE

NEUTRAL
YELLOW

YELLOW RED
RED
BLUE
BLUE
LAMP
LAMP

BALLAST

PREHEAT WITH STARTER

LINE BLACK

BALLAST
LAMP
S

INSTANT START
LINE

NEUTRAL
BLUE
BLUE
RED
LAMP
LAMP

BALLAST

2. Re-wire fixture as shown below.

1. Cut all existing connections to ballast as shown below and remove ballast. See Figure A for typical ballast configurations. Note: Single-ended wiring requires non-shunted lampholders.

CAUTION: INSTANT START BALLASTS
HAVE SHUNTED LAMPHOLDERS.

DOUBLE-ENDED WIRING DIAGRAM

POWER SOURCE

LINE NEUTRAL

NEUTRAL
LINE
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
No Live
Connection
Side A
Side B
Side A
Side B
Side A Side A
Side B Side B

1. Cut all existing connections to ballast as shown below and remove ballast. See Figure A above for typical ballast configurations.

LINE NEUTRAL
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Side A
Side B
Side A
Side B
Side A Side A
Side B Side B
Shunted Lampholders

LINE NEUTRAL
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Side A
Side B
Side A
Side B
Side A Side A
Side B Side B
Nonshunted Lampholders

2. Re-wire fixture as shown below. For Double-ended wiring, use either shunted or nonshunted lampholders.

Note: There should not be any exposed wires at the end of installation.

Keystone Technologies • Philadelphia, PA • Phone (800) 464-2680 • www.keystonetech.com Specifications subject to change. Last revised on 12.12.19

SINGLE- OR DOUBLE-ENDED LINE VOLTAGE LED TUBES
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8

ORDERING INFORMATION
ORDER CODE PACKAGING STYLE PACK QTY. ITEM STATUS
KT-LED12T8-36GC-840-DX2-CP Carton Pack (Egg Crate Packaging) 25 Quick Ship

PHYSICAL CHARACTERISTICS

LAMP DIMENSIONS
A (Illuminated Length) 31.81”
B (Body Length) 35.19”
C (Diameter) 1.10”
NOMINAL LENGTH: 36” BASE TYPE: G13 (Medium Bi-Pin)
C
B
A
KT-LED12T8-36GC-840-DX2
T8 LED LAMP

Page 3 of 3 ends

CATALOG NUMBER BREAKDOWN
KT-LED12T8-36GC-840-DX2-CP
1 2 3 4 5 6 7 8 9 10
1 Keystone Technologies
2 LED Lamp
3 Wattage
4 Lamp Type
5 Nominal Length (Inches)
6 Glass Coated
7 800 Series
8 Color Temperature
9 Single- or Double-Ended Wiring
10 Packaging Style
Keystone Technologies • Philadelphia, PA • Phone (800) 464-2680 • www.keystonetech.com Specifications subject to change. Last revised on 12.12.19

SINGLE- OR DOUBLE-ENDED LINE VOLTAGE LED TUBES
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 KT-LED10.5T8-48G-840-D
T8 LED LAMP

10.5W T8 LED | 4000K | >83 CRI | High Efficiency

DESCRIPTION
LAMP TYPE: Linear
BULB TYPE: T8 LED
BASE TYPE: G13 (Medium Bi-Pin)
WATTAGE: 10.5W
COLOR TEMPERATURE: 4000K
COLOR RENDERING INDEX (CRI): >83
WARRANTY: 5 Years

Page 1 of 2 ends

Keystone Technologies • 1390 Welsh Road, North Wales, PA 19454 • Phone (800) 464-2680 • Fax (888) 966-0556 • www.keystonetech.com Specifications subject to change. Last revised on 1.23.18

OPERATING SPECIFICATIONS

RATED LIFE
L70 (Hours) 50,000

PHOTOMETRIC CHARACTERISTICS
Color Temperature (CCT) 4000K
Luminous Flux 1730 lm
Color Rendering Index (CRI) >83
Efficacy 160 lm/W
Beam Angle 240º
Visible Light Area 325º

ELECTRICAL CHARACTERISTICS
Input Voltage Power Consumption Power Factor Input Current 120-277Vac 10.5W >0.9 .094A @ 120V
.040A @ 277V

60.8 121.6
182.4
243.2
304.6
2 1

SPECTRAL DISTRIBUTION

POLAR CANDELA DISTRIBUTION
Maximum Candela = 1248.55
Located at Horizontal Angle = 0,
Vertical Angle 0

1. Violet Vertical Plane through Horizontal
Angles (90-270)

2. Green Vertical Plane through Horizontal
Angles (0-180)
Wavelength (nm)
Flux (W/nm)
350 425 500 575 650 725 800

1.0 0.8

0.6 0.4

0.2 0.0
Flux (W/nm)
• Replacement for Conventional Fluorescent Lamp
• 50,000+ Hour Lifetime
• Approximately 40% More Energy Efficient that Standard F32T8 Lamps • Environmentally Friendly: No Mercury Used
• UL Classified
• Operating Temperature: -20ºC/-4ºF to 45ºC/113ºF
• Listed on DLC Qualified Product List
• Integral Driver (Isolated), Eliminates the Need
for External Driver or Ballast
• 100+ Lumens per Watt
• Instant Startup
• Frosted Lens Eliminates Pixelation

PRODUCT FEATURES
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8

ORDERING INFORMATION
ORDER CODE PACKAGING STYLE PACK QTY. ITEM STATUS
KT-LED10.5T8-48G-840-D-CP Carton Pack (Egg Crate Packaging) 25 Quick Ship Keystone Technologies • 1390 Welsh Road, North Wales, PA 19454 • Phone (800) 464-2680 • Fax (888) 966-0556 • www.keystonetech.com Specifications subject to change. Last revised on 1.23.18 KT-LED10.5T8-48G-840-D
T8 LED LAMP

Page 2 of 2 ends

PHYSICAL CHARACTERISTICS

LAMP DIMENSIONS
A (Illuminated Length) 44.38”
B (Body Length) 47.15”
C (Diameter) 1.10”
NOMINAL LENGTH: 48” BASE TYPE: G13 (Medium Bi-Pin)
C
B
A
Connect wires directly to these terminals
Typical Non-Shunted Lampholder
CAUTION: Use only
non-shunted lampholders.

Do not install product in a fixture
with shunted lampholders (found
in all fixtures using instant start ballasts). If the current lampholders are shunted, remove them and
replace them with non-shunted
lampholders. Make new connections directly to terminals as indicated above.

Keystone can provide any style
replacement lampholders.

Call us at 800-464-2680.

WIRING DIAGRAMS

1. Cut all existing connections to ballast as shown below and remove ballast.

Typical Ballast Configurations:

PROGAM START
LINE

NEUTRAL
YELLOW

YELLOW RED
RED
BLUE
BLUE
LAMP
LAMP

BALLAST

PREHEAT WITH STARTER

LINE BLACK

BALLAST
LAMP
S
CAUTION: INSTANT START BALLAST
WITH SHUNTED SOCKETS.

INSTANT START
LINE

NEUTRAL
BLUE
BLUE
RED
LAMP
LAMP

BALLAST

NEUTRAL

POWER SOURCE
LINE

NEUTRAL
LINE
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
Direct Drive LED Tube
No Live
Connection

2. Re-wire fixture as shown below.

CATALOG NUMBER BREAKDOWN
KT-LED10.5T8-48G-840-D-CP
Keystone
Technologies
LED Lamp Nominal
Length
(Inches)
Lamp
Type
800
Series
Wattage Glass Color
Temp.

Packaging
Style
Direct
Drive
Series
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 1 Attachment “E”
Community Workforce Agreement
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 2 COMMUNITY WORKFORCE AGREEMENT
For the City of San Leandro
This Agreement is made and entered into this day of , by and between the City of San Leandro ("City") together with contractors and sub-contractors of all tiers, who shall become parties to this Agreement by signing the "Agreement to be Bound" (Attachment A), and the Alameda County Building & Construction Trades Council and its affiliated local Unions who have executed this Agreement.

PURPOSE
The purpose of this Agreement is to support the efforts of the City to increase employment opportunities for workers who reside in San Leandro, to help increase training and employment opportunities for the City's students in the construction trades through apprenticeship and pre-apprentice programs as the students graduate from the City's schools, to promote efficiency of construction operations performed for and within the City of San Leandro and to provide for peaceful settlement of labor disputes and grievances without strikes or lockouts, thereby promoting the public interest in assuring the timely and economical completion of the projects.

RECITALS
WHEREAS, the successful completion of the City's construction projects is of the utmost importance to the City of San Leandro; and
WHEREAS, the interests of the general public, the City, the Unions and Contractor(s) would be best served if the construction work proceeded in an orderly manner without disruption because of strikes, sympathy strikes, work stoppages, picketing, lockouts, slowdowns or other interferences with work; and
WHEREAS, the Contractor(s) and the Unions desire to mutually establish and stabilize wages, hours and working conditions for the workers employed on construction work for and within the City of San Leandro by the Contractor(s), and further, to encourage close cooperation among the Contractor(s) and the Union(s) to the end that a satisfactory, continuous and harmonious relationship will exist among the parties to this Agreement; and WHEREAS, the parties agree that one of the primary purposes of this Agreement is to avoid the tensions that might arise on the Project if Union and non-union workers of different employers were to work side by side on the Project, thereby leading to labor disputes that could delay completion of the Project; and
WHEREAS, this Agreement is not intended to replace, interfere with, abrogate, diminish or modify existing local or national collective bargaining agreements in effect during the duration of the Project, insofar as a legally binding agreement exists between the Contractor(s)/Employer(s) and the affected Union(s), except to the extent that the provisions of this Agreement are inconsistent with said collective bargaining agreements, in which event, the provisions of this Agreement shall prevail; and
06 December
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 3 WHEREAS, contracts for construction work within the City of San Leandro will be awarded in accordance with the applicable provisions of the Charter of the City of SanLeandro, the California State Public Contract Code and the Labor Code, including but not limited to competitive bidding and payment of prevailing wages; and WHEREAS, the City of San Leandro has the absolute right to select the lowest responsive and responsible bidder for the award of the construction contracts for the Projects; and
WHEREAS, the parties signatory to this Agreement pledge their full good faith and trust to work towards a mutually satisfactory completion of the Projects.

NOW, THEREFORE, IT IS AGREED BETWEEN AND AMONG THE PARTIES HERETO, AS FOLLOWS:

ARTICLE 1

DEFINITIONS

1.1 “Agreement” means this Community Workforce Agreement.

1.2 “Agreement to be Bound” means the agreement (attached hereto and incorporated herein as Exhibit A) which shall be executed by each and every Contractor(s)/Employer(s) as a condition of performing Project Work.

1.3 “Alameda County Residents” shall include any residents living in any city or unincorporated section of Alameda County six months prior to the award of a Project.

1.4 “San Leandro Resident” means any individual who six months prior to the award of a Project can certify through a utility bill, or other similar means acceptable to the parties to this Agreement that the individual resides within the boundaries of the San Leandro City Limits.

1.5 “City” means the City of San Leandro.

1.6 “Completion” means that point at which there is Final Acceptance by the City of a Construction Contract. For this definition of “Completion”, “Final Acceptance” shall mean that point in time at which the engineer for the City has determined upon final inspection that the work has been completed in all respects and all required contract documents, contract drawings, warranties, certificates, manuals and data have been submitted and training completed in accordance with the contract documents and the City Council has accepted the work.

1.7 “Contractor(s)” or “Contractor(s)/Employer(s)” means any individual, firm, partnership or corporation, or other business entity, or combination thereof, including joint ventures that is an independent business enterprise, and their successors and assigns that has entered into a contract with the City with respect to the construction work necessary for any part of a Project, under contract terms and conditions approved by the City and which incorporate this Agreement, and any of its contractors or subcontractors of any tier.

1.8 “Construction Contract(s)” means all of the contract(s) for construction of any Project.

1.9 “Council” means the Alameda County Building and Construction Trades Council, AFLCIO.

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 jurisdiction of one of the Unions and which is directly part of the Project, including, without 4 1.10 “New Apprentice” means a San Leandro Resident who is indentured in a State of California approved apprenticeship program that is a joint labor-management apprentice program for no more than twenty-four months.

1.11 “Project” means any construction project awarded by the City, by and through its City Council, and paid for in whole or in part out of City General Fund or City Enterprise Fund monies, the value of which, either estimated by the City or bid by the Contractor, exceeds $1,000,000.00. The City and the Council may mutually agree in writing to add additional components to a Project’s Scope of Work that is covered under this Community Workforce Agreement.

1.12 “Union” or “Unions” means the Council and any affiliated labor organization signatory to this Agreement, acting on their own behalf and on behalf of their respective affiliates and member organizations, whose names are subscribed hereto and who have through their officers executed this Agreement.

1.13 “Project Manager” means the person or persons or business entity designated by the City to oversee all phases of construction on the Projects.

1.14 “Schedule A Agreement” or “Master Labor Agreement” means the local master labor agreement of a Union signatory to this Agreement.

ARTICLE 2

SCOPE OF AGREEMENT

2.1 Parties: This Agreement shall apply and is limited to all Contractors/Employers (including subcontractors at any tier) performing work under Construction Contracts necessary for the Projects, the City, the Council and any affiliated labor organization signatory to this Agreement, acting in their own behalf and on behalf of their respective affiliates and member organizations, whose names are subscribed hereto and who have through their officers executed this Agreement.

2.2 Project Description: This Agreement shall apply to the award of all of the Construction Contracts identified by the City as part of the Projects. The City has the absolute right to combine, change, consolidate, suspend or cancel Construction Contract(s) or portions of Construction Contract(s) identified as part of the Projects. Should the City suspend or remove any individual project from the Projects and thereafter authorize that construction work be commenced on such project, then such project shall be performed under the terms of this Agreement. Once a Construction Contract is completed it is no longer covered by this Agreement except when a Contractor is directed to engage in repairs, warranty work or modifications required by its Construction Contract with the City.

2.3 Covered work:

2.3.1 This Agreement covers, without limitation, all on-site preparation, surveying, construction, alteration, demolition, installation, improvement, painting or repair of buildings, structures and other works, and related activities for the Project that is within the craft limitation to the following examples, geotechnical and exploratory drilling, temporary HVAC, landscaping and temporary fencing, pipelines (including those in linear corridors built to serve the project), DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 jurisdiction of one of the Unions and which is directly part of the Project, including, without 5 pumps, pump stations, and modular furniture installation. On-site work includes work done for the Project in temporary yards, dedicated sites, or areas adjacent to the Project, and at any onsite or off-site batch plant constructed solely to supply materials to the Project. Covered work includes all soils and materials testing and inspection where such testing and inspection is a classification in which a prevailing wage determination has been published.

2.3.2 This Agreement shall apply to any start-up, calibration, commissioning, performance testing, repair, maintenance, and operational revisions to systems and/or subsystems performed after Completion unless it is a new contract and falls below the threshold identified in section 1.11, or is performed by City Employees.

2.3.3 This Agreement covers all on-site fabrication work over which the City or Contractor(s)/ Employer(s) possess the right of control (including work done for the Project in any temporary yard or area established for the Project). Additionally, this Agreement covers any off-site work, including fabrication necessary for the Project defined herein, that is covered by a current Schedule A Agreement or local addenda to a National Agreement of the applicable Union(s) that is in effect as of the execution date of this Agreement.

2.3.2 The furnishing of supplies, equipment or materials which are stockpiled for later use shall not be covered by this Agreement. However, construction trucking work such as the delivery of ready-mix, asphalt, aggregate, sand or other fill material which are directly incorporated into the construction process as well as the off-hauling of debris and excess fill, material and/or mud, shall be covered by the terms and conditions of this Agreement. Employers, including brokers, of persons providing construction trucking work shall provide certified payroll records to the City within ten (10) days of written request or as required by bid specifications. 0 2.3.3 The on-site installation or application of all items shall be performed by the craft having jurisdiction over such work as set forth under the provisions of this Agreement; provided, however, it is recognized that installation of specialty items which may be furnished by the owner of the Project or a Contractor shall be performed by construction persons employed under this Agreement who may be directed by other personnel in a supervisory role; provided, however, in limited circumstances requiring special knowledge of the particular item(s), work may be performed by construction persons of the vendor or other companies where necessary to protect a manufacturer's warranty. The issue of whether it is necessary to use construction persons of the vendor or other companies to protect the manufacturer's warranty shall be subject to the grievance and arbitration clause of this Agreement.

2.4 Exclusions: The following shall be excluded from the scope of this Agreement:

2.4.1 This Agreement is not intended to, and shall not affect or govern the award of public works contracts by the City that are outside the identified scope of work of the Projects.

2.4.2 This Agreement shall not apply to a Contractor or subcontractor's non-craft executives, managerial employees, engineering employees, design employees, supervisors (except those DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 covered by existing building and construction trades collective bargaining agreements), office 6 and clerical employees.

2.4.3 This Agreement shall not apply to any work performed on or near or leading to the site of work covered by this Agreement that is undertaken by state, county or other governmental bodies or their contractors; or by public or private utilities or their contractors; or by the City or its contractors for work not part of the scope of the Projects. Further, this Agreement shall not be construed to prohibit or restrict the City or its employees from performing work on or around the Project construction sites or from entering Project sites for any purposes deemed necessary or appropriate by the City.

2.4.4 This Agreement shall not apply to the off-site maintenance of leased equipment or the on-site supervision of such work.

2.4.5 In the event that the City becomes aware or is made aware that this Agreement or portions thereof are inconsistent with the terms and conditions of any grant, loan, or contract with any Federal, State, or regional agency or with the instructions or directions of an authorized representative of a Federal, State or regional agency to which the City is applying for or has received grant funds, the City shall notify the Council. Within 24 hours of notification, the parties shall meet and confer to attempt to modify the Agreement to avoid the forfeiture of any funding or to otherwise resolve the issue. Should the parties be unable to come to an accord, this Agreement or any inconsistent provision shall be modified, subject to the approval of the City Council, to remain in compliance with the requirements of the applicable funding source.

2.5 Termination, Suspension and/or Delay of Work: It is understood and agreed that the City, at its sole option, may change, terminate, delay and/or suspend any and all portions of Covered Work at any time. Further, the City may prohibit some or all work on certain days or during certain hours of the day to comply with applicable codes, laws or regulations, permits or to accommodate the ongoing operations of the City's facilities and/or to mitigate the effects of the ongoing Projects' work on the businesses and residents in the neighborhoods of the Project sites; and/or require such other operational or schedule changes that may be deemed necessary, in its sole judgment, to effectively maintain the primary purpose of the City's facilities and to remain a good neighbor to the residents and businesses in the immediate area of any Projects. In order to permit the Contractors and Unions to make appropriate scheduling plans, the City will provide the affected Contractor with reasonable notice of any changes, beyond what was stated in the bid documents, that it requires pursuant to this Section.

2.6 Work covered by this Agreement within the following craft jurisdictions shall be performed under the terms of their National Agreements as follows: the NTL Articles of Agreement, the National Stack/Chimney Agreement, the National Cooling Tower Agreement, and the National Agreement of Elevator Constructors, and any instrument calibration work and loop checking shall be performed under the terms of the UA/IBEW Joint National Agreement for Instrument and Control Technicians, with the exception that Articles IV, XI and XII of this Agreement shall apply to such work.

2.7 The parties are hereby notified that any Projects funded in whole or in part by HUD Section 3 financial assistance must provide employment, registered apprenticeship, training, contracting, or other economic opportunities to Section 3 residents and businesses in a manner that is consistent with Section 3 of the Housing and Urban Development Act of 1968.

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 The parties shall meet and confer to modify this Agreement when and where necessary to 7 comply with HUD regulations.

ARTICLE 3

EFFECT OF AGREEMENT/SUBCONTRACTORS

3.1 By executing this Agreement, the Unions and the City agree to be bound by each and every provision of this Agreement.

3.2 By accepting the award of a Construction Contract for a Project, whether as contractor or subcontractor at any tier thereunder, the Contractor/Subcontractor agrees to be bound by each and every provision of this Agreement.

3.3 This Agreement shall only be binding on the signatory parties hereto, their successors and assigns, and shall not apply to the parents, affiliates, subsidiaries, or other ventures of any such party unless performing work within the scope of the Project(s).

3.4 The provisions of this Agreement, including the Schedule A agreements, which are incorporated herein by reference and which are the local Master Agreements of the Signatory Unions having jurisdiction over the work on the Project, shall apply to the work covered by this Agreement, notwithstanding the provisions of any other local, area and/or national agreements which may conflict with or differ from the terms of this Agreement. It is understood that this Agreement, together with the referenced Schedule A Agreements, constitute an integrated, selfcontained, stand-alone agreement, and that by virtue of having become bound to this Agreement, the Contractor will not be obligated to sign any other local, area, or national agreement as a condition of performing work within the scope of this Agreement. Where a subject covered by the provisions of this Agreement is also covered by a Schedule A, the provisions of this Agreement shall prevail. Where a subject is covered by the provisions of a Schedule A and is not covered by this Agreement, the provisions of the Schedule A shall prevail.

3.5 In addition, it is understood and agreed that all grievances and disputes involving the interpretation or application of this Agreement, including the Schedule A Agreements, shall be resolved according to the procedures set forth in Article 11 of this Agreement; provided, however, that should a dispute involve a single Schedule A Agreement and a Contractor signatory thereto, and not involve interpretation or application of this Agreement, then such dispute shall be processed and resolved pursuant to the grievance provisions of that Schedule A Agreement. Should there be a dispute in the first instance as to whether the provisions of Article 11 of this Agreement or the grievance procedures of a Schedule A Agreement apply, the dispute shall be presented initially to an arbitrator who shall be selected pursuant to the method described in Article 11. Such referral of a dispute as to the applicable procedures shall be done by an immediate conference call among the parties and the arbitrator, and be heard and decided within three (3) calendar days. Should the arbitrator hold that Article 11 applies, the parties may, by mutual agreement, submit the issue to the same arbitrator pursuant to the provisions of Article 11, or, absent mutual agreement, commence processing the dispute at Step 1 of that Article.

3.6 Subcontractors: At the time that any Contractor enters into a subcontract with any subcontractor of any tier for the performance of construction or construction trucking work DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 8 within the scope of this Agreement, the Contractor shall provide a copy of this Agreement, as it may from time to time be modified by the negotiating parties, to said subcontractor and shall require the subcontractor, as a part of accepting an award of a construction subcontract, to agree to be bound by each and every provision of the Agreement prior to the commencement of work.

3.6.1 Each Contractor and Subcontractor shall evidence their agreement to be bound to this Agreement by executing the Agreement To Be Bound form attached hereto as Exhibit A. A copy of the Agreement To Be Bound executed by the Contractors and Subcontractors shall be submitted to the Council and the Union(s) prior to both the commencement of work and the PreJob Conference and will be a required submittal within the City's bid packages. If the Contractor or Subcontractor refuses to execute the Agreement To Be Bound, then such Contractor or Subcontractor shall not be awarded a Construction Contract to perform work on the Projects. A Contractor or Subcontractor who executes the Agreement to Be Bound shall be considered a signatory party to this Agreement.

3.6.2 It is understood that the liability of each Contractor and Subcontractor and the liability of each Union under this Agreement shall be several and not joint. Any dispute between the Union(s) and the Contractor/Employer respecting compliance with the terms of the Agreement shall not affect the rights, liabilities, obligations and duties between the signatory Union(s) and other Contractor(s)/Employer(s) party to this Agreement. Any alleged breach of this Agreement by a signatory Union shall not affect the rights, liabilities, obligations and duties between the signatory Contractor(s)/Employer(s) and the other Union(s) party to this Agreement. The Unions agree that this Agreement does not have the effect of creating any joint employment status between or among the City and/or any Contractor orSubcontractor.

3.6.3 With regard to any Contractor or subcontractor that is independently signed to any Schedule A Agreement, this Agreement shall in no way supersede or prevent the enforcement of any subcontracting clause contained in such Schedule A Agreement. Any such subcontracting clause in a Schedule A Agreement shall remain and be fully enforceable between each craft union and its signatory employers and no provision of this Agreement shall be interpreted and/or applied in any manner that would give this Agreement precedence over subcontracting obligations and restrictions that exist between craft Unions and their respective signatory employers under a Schedule A Agreement. To the extent that the provisions of this Agreement are inconsistent with any other provisions contained in a Schedule A Agreement, the provisions of this Agreement shall prevail.

ARTICLE 4
WORK STOPPAGES. STRIKES, SYMPATHY STRIKES AND LOCKOUTS

4.1 The Unions, City and Contractor agree that for the duration of the Projects:

4.1.1 There shall be no strikes, sympathy strikes, work stoppages, picketing, hand billing or otherwise advising the public that a labor dispute exists, or slowdowns of any kind, for any reason, by the Unions or construction persons employed on the Projects, at a job site of the Projects or at any other facility of the City because of a dispute on the Projects. Nor shall the Unions or construction persons employed on the Projects participate in any strikes, sympathy strikes, work stoppages, picketing, hand billing, slowdowns, or otherwise advising the public that a labor dispute exists at a Project jobsite because of a dispute between Unions and Contractor(s) on any other project.

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 9 4.1.2 As to construction persons employed on the Projects, there shall be no lockout of any kind by a Contractor covered by this Agreement

4.1.3 If a Schedule A Agreement between a Contractor and the Union expires before the Contractor completes the performance of a Construction Contract and the Union or Contractor gives notice of demand for a new or modified Schedule A Agreement, the Union agrees that it will not strike, picket, hand-bill, slowdown or engage in any other disruptive activity against the Contractor and the Contractor will not lock out construction persons of the Union on said Construction Contract for work covered under this Agreement and the Union and the Contractor agree that the expired Schedule A Agreement shall continue in full force and effect for work covered under this Agreement until a new or modified Schedule A Agreement is reached. If the new or modified Schedule A Agreement provides that any terms of the new Schedule A Agreement shall be retroactive, the Contractor agrees to comply with any retroactive terms of the new or modified Schedule A Agreement applicable to construction persons employed on the Projects within seven (7) days.

4.1.4 It shall not be considered a violation of this article for a Union to withhold labor (but not picket) from any Contractor/Employer who fails to make its timely payment of Trust Fund contributions or fails to meet its weekly payroll. The affected Union shall give seventy-two (72) hours written notice to the City and to the Contractor/Employer prior to withholding labor due to a Contractor's failure to make timely payment of Trust Fund contributions and twenty-four (24) hours written notice to the City and to the Contractor/Employer when a Contractor/Employer fails to make weekly payroll or when paychecks are determined to be nonnegotiable by a financial institution normally recognized to honor such paychecks, during which time the Contractor/Employer shall have the opportunity to correct the default.

4.1.5 If the City contends that any Union has violated this Article, it will notify in writing (including email) the Secretary-Treasurer/Business Manager/Senior Executive of the Council and the Senior Executive of the Union, setting forth the facts alleged to violate the Article, prior to instituting the expedited arbitration procedure set forth below. The Council will immediately use its best efforts to cause the cessation of any violation of this Article. The leadership of the Union will immediately notify the membership of its obligations under this Article.

4.2 Expedited Arbitration: Any party to this Agreement shall institute the following procedure, in lieu of or prior to any other action at law or equity, when a breach of this Article 4 is alleged to have occurred:

4.2.1 A party invoking this procedure shall notify Robert Hirsch whom the parties agree shall be the permanent arbitrator under this procedure. In the event that the permanent arbitrator is unavailable at any time, William Riker shall be the alternate arbitrator. If neither is available, then the arbitrator shall be chosen from the list provided in Article XI. Notice to the arbitrator shall be by the most expeditious means available, with notices by facsimile, electronic mail or telephone to the party alleged to be in violation, to the City, to the Council and to the involved local Union if a Union is alleged to be in violation of thisAgreement.

4.2.2 Upon receipt of said notice, the arbitrator shall convene a hearing within twenty-four (24) hours if it is contended that the violation still exists.

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 10 4.2.3 The Arbitrator shall notify the parties by facsimile, electronic mail or telephone of the place and time for the hearing. Said arbitration shall be completed in one session, which, with appropriate recesses at the arbitrator's discretion, shall not exceed twenty-four (24) hours unless otherwise agreed upon by all parties. A failure of any party to attend said hearings shall not delay the hearing of evidence or the issuance of any award by the arbitrator.

4.2.4 The sole issue at the hearing shall be whether or not a violation of Article 4, Section

4.1 of this Agreement has occurred. The arbitrator’s decision shall be issued in writing within three (3) hours after the close of the hearing, and may be issued without a written opinion. If any party desires a written opinion, one shall be issued within fifteen (15) calendar days, but its issuance shall not delay compliance with or enforcement of the award. The arbitrator may order cessation of the violation of this Article 4 and other appropriate relief and such award shall be served on all parties by hand or the most expedient means allowed by law that meets the timelines set forth herein.

4.2.5 Such award may be enforced by any Court of competent jurisdiction upon the filing of this Agreement and all other relevant documents referred to above in the following manner:

Written notice of the filing of such enforcement proceedings shall be given to the other party. In the proceeding to obtain a temporary order enforcing the arbitrator's decision as issued under Section 4.2.4 of this Article 4, all parties waive the right to a hearing and agree that such proceedings may be ex parte. Such agreement does not waive any party's right to participate in a hearing for a final order of enforcement. The Court's order or orders enforcing the arbitrator's award shall be served on all parties by hand or the most expedient means allowed by law that meets the timelines set forth herein.

4.2.6 Any rights created by statute or law governing arbitration proceedings inconsistent with the above procedure or which interfere with compliance are waived by the parties.

4.2.7 The fees and expenses of the arbitrator shall be divided equally between the party instituting the arbitration proceedings provided in this Article and the party alleged to be in breach of its obligations under this article.

4.3 Liquidated Damages: If the arbitrator determines that a violation of Section 4.1 has occurred, the breaching party shall, within eight (8) hours of the issuance of the decision take all steps necessary to immediately cease such activities and return to work. If the breaching party involved does not cease such activities by the beginning of the next regularly scheduled shift following the expiration of the eight (8) hour period after the arbitrator’s issuance of the decision, then the breaching party shall pay the sum of ten thousand dollars ($10,000) as liquidated damages to the City per shift until the breach is remedied. The arbitrator shall retain jurisdiction for the sole purpose of determining compliance with this obligation and determining the amount of liquidated damages, if any; but such retention shall not prevent the moving party from seeking judicial enforcement of the initial decision.

ARTICLE 5

PRE-JOB CONFERENCE

5.1 A mandatory pre-job conference shall be held after the award of the Construction Contract and prior to the commencement of work. Such conference shall be attended by a DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 11 representative from the participating Contractor(s), including all sub-contractors, and Union(s) and the Project Manager. All efforts will be made to hold the pre-job conference in sufficient time to ensure all parties the ability to properly raise and resolve any issue that may arise out of such meeting, with a goal that such conferences will be held at least ten (10) days before the work commences. Unless otherwise agreed to by the parties, all pre-job conferences will be held at San Leandro City Hall.

ARTICLE 6

NO DISCRIMINATION

6.1 The Contractors and Unions agree not to engage in any form of discrimination based on any protected class, including but not limited to race, color, creed, religion, national origin, ancestry, age, sex, sexual orientation or disability against any person, or applicant for employment on the Projects.

ARTICLE 7

UNION SECURITY

7.1 The Contractors recognize the Union(s) as the sole bargaining representative of all construction persons working within the scope of this Agreement.

7.2 All construction persons who are employed by the Contractor(s) shall, as a condition of employment, on or before the eighth (8th) day of consecutive or cumulative employment on the Projects, be responsible for the payment of the applicable monthly working dues and any associated fees uniformly required for union membership in the applicable local union which is signatory to this Agreement. Further, there is nothing in this Agreement that would prevent nonunion construction persons from joining the local union.

7.3 Authorized representatives of the Unions shall have access to the Projectswhenever work covered by this Agreement is being performed on the Project.

ARTICLE 8

REFERRAL AND LOCAL HIRE PROGRAM

8.1 Referral:

8.1.1 Contractor(s) performing construction work on the Projects described in the Agreement shall, in filling craft job requirements, utilize and be bound by the registration facilities and referral systems established or authorized by the Unions signatory hereto ("Job Referral System"). Such Job Referral System will be operated in a non-discriminatory manner and in full compliance with all federal, state, and local laws and regulations, including those which require equal employment opportunities and nondiscrimination.

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 12 8.1.2 The Contractor(s) shall have the right to reject any applicant referred by the Union(s), in accordance with the applicable Master Agreement.

8.1.3 The Contractor(s) shall have the unqualified right to select and hire directly all supervisors above general foreman it considers necessary and desirable, without such persons being referred by the Unions(s).

8.1.4 In the event that referral facilities maintained by the Union(s) are unable to fill the requisition of a Contractor(s) for employees within a seventy-two (72) hour period after such requisition is made by the Contractor(s), the Contractor(s) shall be free to obtain employees from any source. Contactor(s) shall promptly notify the Union(s) of any applicants hired from other sources. This provision does NOT affect core employees as defined below.

8.1.5 Unions shall exert their utmost efforts to recruit sufficient numbers of skilled craft persons to fulfill the requirements of the Contractor(s).

8.2 Local Hire:

8.2.1 All parties agree to make a good faith effort to refer on a priority basis, consistent with the non-discriminatory referral procedures of the hall, qualified and available, and bona-fide San Leandro residents and if no San Leandro residents are available, then Alameda County Residents, for Project work.

8.2.2 The parties also recognize and support the City's commitment to provide opportunities for participation on the Projects to San Leandro businesses through the City’s Local Business Preference Ordinance. In furtherance of this commitment, the parties agree that such San Leandro contractors and subcontractors awarded work on the Projects may request by name, and the local will honor, referral of persons who have applied to the local union for Project work and who demonstrate the following qualifications:
(1) possess any license required by state or federal law for the Project work to be performed; (2) have worked a total of at least one thousand (1,000) hours in the construction craft during the prior three (3) years;
(3) were on the Contractor's active payroll for at least sixty (60) out of the one hundred and twenty (120) calendar days prior to the contract award; (4) have the ability to perform safely the basic functions of the applicable trade, and (5) are San Leandro residents.

The Union will refer to such Contractor one journeyman employee from the hiring hall out-ofwork list for the affected trade or craft, and will then refer one of such Contractor's "core" employees as a journeyman and shall repeat the process, one and one, until such Contractor's crew requirements are met or until such Contractor has hired five (5) "core" employees, whichever occurs first. Thereafter, all additional employees in the affected trade or craft shall be hired exclusively from the hiring hall out-of-work list(s). For the duration of the Contractor's work the ratio shall be maintained and when the Contractor's workforce is DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 13 reduced, employees shall be reduced in the same ratio of core employees to hiring hall referrals as was applied in the initial hiring.

8.2.3 The Contractor shall notify the appropriate Union of the name and social security number of each direct hire and each direct hire shall register with the Union's hiring hall before commencing Project work. If there is any question regarding an employee's eligibility under this Subsection, the City Representative, at a Union's request, shall obtain satisfactory proof of such from the Contractor.

8.2.4 To the extent allowed by law and consistent with the non-discriminatory referral procedures of the Union hiring halls, the Parties agree to a goal that San Leandro Residents shall perform a minimum of 30% of the hours worked, on a craft by craft basis, on the Projects.

In the event that no San Leandro residents are available to fulfill the 30% local hire requirement, the next tier of residents shall come from anywhere in Alameda County. The Contractor(s) shall make good faith efforts to reach this goal through the utilization of the Unions' hiring hall procedures. The Unions shall exercise their best efforts in their recruiting and training of San Leandro Resident workers and in their hiring hall procedures to facilitate this 30% goal.

8.2.5 Should any Contractor performing work on the Projects exceed the 30% local hire goal as set forth in this Agreement, they shall be acknowledged by the City Council for theirefforts.

8.3 Apprenticeship Provision:

8.3.1 Consistent with the requirements of California Labor Code §§ 1776, 1777.5 and 1777.6, Prime Contractor(s), and or their sub-contractors shall hire 1 San Leandro resident as a New Apprentice for the first 1 million dollars of the total bid amount. Thereafter, for every 5 million dollars of the total bid amount the Prime Contractor and their Sub-contractors will be required to hire one additional New Apprentice. The New Apprentice(s) must work a minimum of 10% of the project’s work hours. The contractor may employ the apprentice on a different concurrent project in order to meet the minimum hours, and those hours will be counted towards the total hours of the craft on the San Leandro project. Certified Payrolls must reflect the hours worked by persons that fall under this Subsection.

8.3.2 There shall be no more than 1 entry-level apprentice for each craft, provided said crafts have apprenticeship openings and the general contractor is able to include entry-level apprentices hired by their subcontractors to meet this requirement. The City, upon request, will refer names of graduates of workforce development programs to the Unions and Contractors and the Unions will agree to cooperate with Contractor(s) to furnish apprentices as requested.

The hiring of apprentices will be in accordance with the Apprenticeship provisions of the applicable Master Agreements and the standards and procedures of the applicable JATC program approved by the division of apprenticeship standards. Apprentices shall be properly supervised and paid in accordance with provisions contained within the MasterAgreements.

8.3.4 The intent of this provision is to utilize San Leandro Resident First Period Apprentices to the fullest extent permissible by state law and the Master Agreements. Failure of Contractor(s) and their subcontractors to maintain qualified apprentices on the job will be subject to Division of Apprenticeship Standards penalties, and further penalties as determined by the Joint Administrative Committee.

8.4 Should any of the contractors performing work on the Projects fail to meet this 30% local goal and the apprenticeship requirements set forth in this article or fail to demonstrate "good DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 14 faith" efforts to do so, through a specific submittal process to be included in their contractual requirements, the City reserves the right to withhold the 5% retention on current progress payments until such time that this failure is remedied, but not longer than ninety (90) days after the date of substantial completion of the Projects or as required by law. However, Enforcement of this Article will be through the Grievance Procedure set forth in Article 11.

ARTICLE 9

GRIEVANCE PROCEDURE

9.1 All disputes involving discipline and/or discharge of employees working on the Project shall be resolved through the grievance and arbitration provision contained in the Master Agreement for the craft of the affected employee. No employee working on the Project shall be disciplined or dismissed without just cause.

ARTICLE 10

JOINT ADMINISTRATIVE COMMITTEE

10.1 The parties to this Agreement shall establish a five (5) person Joint Administrative Committee. This Committee shall be comprised of two (2) representatives selected by the City; two (2) representatives of the signatory Unions and Alameda County Building and Construction Trades Council; and one (1) industry representative, mutually selected by the City and the Alameda County Building and Construction Trades Council. Each representative shall designate an alternate who shall serve in his or her absence for any purpose contemplated by this Agreement.

10.2 The Joint Administrative Committee shall meet as required, but not less than once each quarter, to review the implementation of the Agreement and the progress of the Projects including, but not limited to, compliance with Article 8, prevailing wage, safety, craft workforce levels and construction progress. Requests for certified payrolls from the Joint Labor/Management Committee to which the Union(s) signatory to this Agreement are a party shall be provided as required by law.

ARTICLE 11

GRIEVANCE ARBITRATION PROCEDURE

11.1 The parties understand and agree that in the event any dispute arises out of the meaning, interpretation or application of the provisions of this Agreement, the same shall be settled by means of the procedures set forth herein. No grievance shall be recognized unless the grieving party provides notice in writing to the signatory party with whom it has a dispute within seven (7) calendar days after becoming aware of the dispute, but in no event more than thirty (30) calendar days after it reasonably should have become aware of the event causing the dispute. The time limits in this Article 11 may be extended by mutual written agreement of the parties.

11.2 Grievances shall be settled according to the following procedures:

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 15 Step 1: Within seven (7) calendar days after the receipt of the written notice of grievance, the necessary parties to the grievance, including but not limited to the Business Representative of the involved Local Union, or the City's authorized representative or his/her designee, or the representative of the construction person, or the representative of the involved Contractor shall confer and attempt to resolve the grievance.

Step 2: In the event that the representatives are unable to resolve the dispute within seven (7) calendar days after its referral to Step 1, either involved party may submit the dispute within three (3) calendar days to a subcommittee of the Joint Administrative Committee consisting of one (1) person selected by the City and one (1) person selected by the Council, which shall meet within seven (7) calendar days after such referral (or such longer time as mutually agreed upon by all representatives of the subcommittee), to confer in an attempt to resolve the grievance. If there is a unanimous decision by the subcommittee, the decision will be binding on all parties. The Union(s) shall notify its International Union representative(s), which shall advise both parties if it intends on participating in a Step 2 meeting. If the dispute is not resolved within such time (seven (7) calendar days after its referral or such longer time as mutually agreed upon) it may be referred within seven (7) calendar days by either party to Step

3. Step 3: In the event the matter is not settled or otherwise resolved in a final and binding manner by the Committee, either party may demand arbitration. The parties shall provide a list to each other of their preferred arbitrators. The parties shall flip a coin to determine who shall strike the first name and shall then alternatively strike names from the list and the last remaining name shall be the neutral third party arbitrator who shall have the power to resolve the dispute in a final and binding manner. The costs of the arbitration shall be evenly split by the parties with each bearing the cost of their own legal counsel. Upon mutual agreement of the parties, the matter may be heard on an expedited basis, by telephone or other electronic means, and the arbitrator may render a "bench decision".

11.3 The Arbitrator shall arrange for a hearing no later than fourteen (14) calendar days after the matter has been submitted to arbitration. A decision shall be given to the parties within five (5) calendar days after completion of the hearing unless such time is extended by mutual agreement. A written opinion may be requested by a party from the Arbitrator. The time limits specified in any step of the Grievance Procedure set forth in Section 11.2 may be extended by mutual agreement of the parties initiated by the written request of one party to the other, at the appropriate step of the Grievance Procedure. However, failure to process a grievance, or failure to respond in writing within the time limits provided above, without the request for an extension of time, shall be deemed a waiver of such grievance without prejudice, or without precedent to the processing of and/or resolution of like or similar grievances or disputes.

11.4 The decision of the Arbitrator shall be binding upon all parties. The Arbitrator shall not have authority to change, amend, add, or detract from any of the provisions of the Agreement.

The expenses of the Arbitrator shall be borne equally by both parties.

11.5 In order to encourage the resolution of disputes and grievances at Step 1 and 2 of this Grievance Procedure, the parties agree that such settlements shall not be precedent setting.

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 16 11.6 Retention: At the time a grievance is submitted under this Agreement or any Master Agreement, the Union(s) may request that the City withhold and retain an amount from what is due and owing to the Contractor(s) against whom the grievance is filed, sufficient to cover the damages alleged in the grievance, should the Union(s) prevail. The amount shall be retained by the City until such time as the underlying grievance giving rise to the retention is withdrawn, settled, or otherwise resolved, and the retained amount shall be paid to whomever the parties to the grievance shall decide, or to whomever an Arbitrator shall so order.

ARTICLE 12

WORK ASSIGNMENTS AND JURISDICTIONAL DISPUTES

12.1 The assignment of Covered Work will be solely the responsibility of the Contractor/Employer(s) performing the work involved. However, such work assignments will be in accordance with the Plan for the Settlement of Jurisdictional Disputes in the Construction Industry (the “Plan”) or any successor Plan.

12.2 All jurisdictional disputes on the Projects between or among the Union(s) shall be settled and adjusted according to the present Plan established by the Building and Construction Trades Department, or any other plan or method of procedure that may be adopted in the future by the Building and Construction Trades Department. Decisions rendered shall be final, binding and conclusive on the Contractor/Employer(s) and Union(s) parties to this Agreement.

12.2.1 If a dispute arising under this Article involves the Northern California Carpenters Regional Council or any of its subordinate bodies, an Arbitrator shall be chosen by the procedures specified in Article V, Section 5, of the Plan from a list composed of John Kagel, Thomas Angelo, Robert Hirsch and Thomas Pagan and the Arbitrator’s hearing on the dispute shall be held at the offices of the California State Building and Construction Trades Council in Sacramento, California, within fourteen (14) calendar days of the selection of the Arbitrator. All other procedures shall be as specified in the Plan.

12.3 All jurisdictional disputes shall be resolved without the occurrence of any strike, work stoppage, or slow-down of any nature, and the Contractor/Employer(s)’ assignment shall be adhered to until the dispute is resolved. Individuals violating this Section shall be subject to immediate discharge.

12.4 Each Contractor/Employer(s) shall conduct a Pre-Job Conference with the Council prior to commencing Covered Work. Pre-job conferences for different Contractor(s) may be held together.

ARTICLE 13

APPRENTICES

13.1 Recognizing the need to develop adequate numbers of competent workers in the construction industry, the Contractor/Employer(s) shall employ apprentices from California Stateapproved Joint Apprenticeship Programs in the respective crafts to perform such work as is within their capabilities and which is customarily performed by the craft in which they are DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 17 indentured.

13.2 Contractors shall at all times comply with the applicable provisions of the California Labor Code, the payment of prevailing wages, the registration of contractors and subcontractors, and the hiring of apprentices, in addition to the requirements of Article 8.

13.3 The apprentice ratios will be in compliance with the applicable provisions of the California Labor Code and Prevailing Wage Rate Determinations.

13.4 HELMETS TO HARDHATS:

13.4.1 The Contractor(s)/Employer(s) and the Unions recognize a desire to facilitate the entry into the building and construction trades of veterans who are interested in careers in the building and construction industry. The Contractor(s)/ Employer(s) and Unions agree to utilize the services of the Center for Military Recruitment, Assessment and Veterans Employment (hereinafter “Center) and the Center’s “Helmets to Hardhats” program to serve as a resource for preliminary orientation, assessment of construction aptitude, referral to apprenticeship programs or hiring halls, counseling and mentoring, support network, employment opportunities and other needs as identified by the parties.

13.4.2 The Unions and Contractor(s)/Employer(s) agree to coordinate with the Center to participate in an integrated database of veterans interested in working on the Projects and of apprenticeship and employment opportunities for the Projects. To the extent permitted by law, the Unions will give credit to such veterans for bona fide, provable past experience.

ARTICLE 14

MANAGEMENT RIGHTS

14.1 The Contractor shall retain full and exclusive authority for the management of its operations, including the right to direct its work force in its sole discretion except as otherwise limited by the terms of this agreement and/or Schedule A Agreements. No roles, customs or practices shall be permitted or observed that limit or restrict production, or limit or restrict the working efforts of construction persons except that the lawful provisions of the Schedule A Agreements shall be recognized.

ARTICLE 15

WAGES/BENEFITS

15.1 All Contractor(s)/Employer(s) agree to pay contributions to the vacation, pension and other form of deferred compensation plan, apprenticeship, worker protection and assistance, and health benefit funds established by the applicable Master Agreement for each hour worked on the Project in the amounts designated in the Master Agreements of the appropriate local Unions.

15.2 By signing this Agreement, the Contractor(s)/Employer(s) adopt and agree to be bound by the written terms of the legally established trust agreements and which may from time to time be amended, specifying the detailed basis on which payments are to be made into, and benefits DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 18 paid out of, such Trust Funds. The Contractors authorize the parties to such local trust agreements to appoint trustees and successor trustees to administer the trust funds and hereby ratify and accept the trustees so appointed as if made by the Contractor(s). The Contractor(s) agrees to execute a separate Subscription Agreement(s) for Trust Funds when such Trust Fund(s) requires such document(s).

15.3 Wages, Hours, Terms and Conditions of Employment: The wages, hours and other terms and conditions of employment on the Project shall be governed by the Master Agreement of the respective crafts, to the extent such Master Agreement is not inconsistent with this Agreement.

Where a subject is covered by the Master Agreement and not covered by this Agreement, the Master Agreement will prevail. When a subject is covered by both the Master Agreement and this Agreement, to the extent there is any inconsistency, this Agreement will prevail.

15.4 Holidays: Holidays shall be established as set forth in the applicable Schedule A.

15.5 If a contractor fails to pay wages, the City agrees to honor a properly submitted, legally enforceable Stop Notice.

ARTICLE 16

MODIFIED SCHEDULE A AGREEMENTS

16.1 Certain Provisions Shall Not Apply. Provisions negotiated into the new or modified Schedule A Agreements which are less favorable to the Contractor than those uniformly required of employers for construction work normally covered by those agreements or which may be construed to apply exclusively or predominantly to work covered by this Agreement shall not apply to work covered by this Agreement. Any disagreement between the parties regarding the application of the provisions of any new or modified collective bargaining agreement to work covered by this Agreement shall be resolved under the dispute and grievance arbitration procedures set forth in Article 12 hereof.

ARTICLE 17

SAVINGS CLAUSE

17.1 The parties agree that in the event any article, provision, clause, sentence or word of this Agreement is determined to be illegal or void as being in contravention of any applicable law, by a court of competent jurisdiction, the remainder of the Agreement shall remain in full force and effect. The parties further agree that if any article, provision, clause, sentence or word of the Agreement is determined to be illegal or void, by a court of competent jurisdiction, the parties shall substitute, by mutual agreement, in its place and stead, an article, provision, clause, sentence or word which will meet the objections to its validity and which will be in accordance with the intent and purpose of the article, provision, clause, sentence or word in question.

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 19 17.2 The parties also agree that in the event that a decision of a court of competent jurisdiction materially alters the terms of this Agreement such that the intent of the parties is defeated, then the entire Agreement shall be null and void.

ARTICLE 18

ENTIRE AGREEMENT

18.1 This Agreement, together with the referenced Schedule A Agreements, represents the complete understanding of the parties: The provisions of this Agreement, including the Schedule A Agreements, shall apply to the work covered by this Agreement. Where a subject covered by the provisions of this Agreement is also covered by a Schedule A Agreement, the provisions of this Agreement shall prevail. Where a subject is covered by the provisions of a Schedule A Agreement and is not covered by this Agreement, the provisions of the Schedule A Agreement shall prevail. Nothing contained in a Schedule A Agreement, working rule, by- law, constitution or other similar document of the Unions shall in any way affect, modify or add to this Agreement unless otherwise specifically set forth in this Agreement or mutually agreed to in a writing executed by the parties.

18.2 The parties agree that this Agreement covers all matters affecting wages, hours, and other terms and conditions of employment and that during the term of this Agreement the parties will not be required to negotiate on any further matters affecting these or any other subjects not specifically set forth in this Agreement except by mutual agreement of theparties.

18.3 This Agreement may be executed in counterparts, such that original signatures may appear on separate pages and when bound together all necessary signatures shall constitute an original. Facsimile and PDF signature pages transmitted to the other parties to this Agreement shall be deemed the equivalent to original signatures.

ARTICLE 19
TERM

19.1 The Agreement shall be included as a condition of the award of the Construction Contracts.

19.2 The Agreement shall be effective as of January 1, 2016 (“Effective Date”).

19.3 The Agreement shall continue in full force and effect for a term of three years from the Effective Date and shall be applicable to all Projects bid during the term until completion.

ARTICLE 20

COMPLIANCE

20.1 It shall be the responsibility of the Contractor(s) and Unions to investigate and monitor compliance with the provisions of this agreement contained in Article 15. Nothing in this DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 20 agreement shall be construed to interfere with or supersede the usual and customary legal remedies available to the Unions and/or employee benefit Trust Funds to collect delinquent Trust Fund contributions from Contractors on the Project. The City shall monitor compliance with the prevailing wage requirements of the state, and the Contractors/Employers’ compliance with this Agreement.

20.2 DRUG & ALCOHOL TESTING:

20.2.1 The use, sale, transfer, purchase and/or possession of a controlled substance, alcohol and/or firearms at any time during the work day is prohibited.

20.2.2 Drug and alcohol testing shall be conducted in accordance with the Substance Abuse Prevention Policies set forth in each applicable Schedule A.

City of San Leandro
By: Date: _
Alameda County Building & Construction Trades Council, AFL-CIO By: Date:

Signatory Unions
Asbestos Workers, Local 16 Boilermakers, Local 549
By: By:

Bricklayers & Allied Craftsmen, Local 3 Cement Masons, Local 300 By: By:

Electrical Workers, Local 595 Elevator Constructors, Local 8 By: By:

Hod Carriers, Local 166 Iron Workers, Local 378
By: By:

Laborers, Local 67 Laborers, Local 304
By: By:

Operating Engineers, Local 3 Plasterers, Local 66
By: By:

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 December 21, 2021 | 4:56:26 PM PST
21 Roofers, Local 81 Sheet Metal Workers, Local 104
By: By:

Sign Display, Local 510 Sprinkler Fitters, Local 483
By: By:

Teamsters, Local 853 United Association of Journeymen and Apprentices Fitting Industry, Underground Utility & Landscape, Local 355
By: By:

United Association of Steamfitters, Plumbers, & Gas Fitters, Local 342 By:

Council No. 16 Northern California
By:

Painters & Allied Trades (On behalf
of Painters, Local 3; Carpet & Linoleum
Layers, Local 12; Glass Workers, Local
169; Auto& Marine Painters, Local 1176)
By:

Northern California Carpenters
Regional Council (on behalf of Carpenters,
Local 713; Carpenters, Local 2236; Lathers,
Local 68L; Millwrights, Local 102; Pile
Drivers, Local 34)
By:

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 22 EXHIBIT A
City of San Leandro Community Workforce Agreement

AGREEMENT TO BE BOUND
The undersigned, as a Contractor or Subcontractor ("Contractor") on a City Project (“Project”), for and in consideration of the award to it of a contract to perform work on said Project, and in further consideration of the mutual promises made in the Project’s Community Workforce Agreement ("Agreement"), a copy of which was received and is acknowledged, hereby:

1. Accepts and agrees to be bound by the terms and conditions of the Agreement, together with any and all amendments and supplements now existing or which are later made to said Agreement.

2. Certifies that it has no commitments or agreements which would preclude its full and complete compliance with the terms and conditions of said Agreement;

3. Agrees to secure from any Contractor (as defined in said Agreement) which is or becomes a subcontractor (of any tier) to it, and from any successors, a duly executed Agreement to be bound in form identical to this document.

4. Contractor agrees that it shall be bound by all applicable trust agreements and plans for the provision of such fringe benefits as accrue to the direct benefit of the construction persons, including Health and Welfare, Pension, Training, Vacation, and/or other direct benefits provided pursuant to the appropriate craft’s Schedule "A" Agreement as set forth in Article 15, as they may from time to time be amended, specifying the detailed basis upon which contributions are to be made into, and benefits made out of, such trust funds, and ratifies and accepts the trustees appointed by the parties to such trust funds. The undersigned party agrees to execute a separate Subscription Agreement(s) when such Trust Fund(s) requires such document(s).

This letter shall constitute a subscription agreement, to the extent of the terms of the letter.

Date:

Company Name:

Name of Prime Contractor or Higher Level Subcontractor:

Name of Project:

Signature:

Print Name:

Title:

Contractor’s License # or Motor Carrier (CA) Permit Number:
426806.1
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 991066
Climatec, LLC
Vice President
Steve Siverson
Energy Project
Climatec, LLC
December 20, 2021 | 9:57:30 AM PST
23 Attachment “F”
Insurance
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 24 NSURANCE REQUIREMENTS. Before fully executing this Agreement, Consultant, at its own cost and expense, unless otherwise specified below, shall procure the types and amounts of insurance listed below against claims for injuries to persons or damages to property that may arise from or in connection with the performance of the work hereunder by the Consultant and its agents, representatives, employees, and subcontractors. Consistent with the following provisions, Consultant shall provide proof satisfactory to City of such insurance that meets the requirements of this section and under forms of insurance satisfactory in all respects, and that such insurance is in effect prior to beginning work. Consultant shall maintain the insurance policies required by this section throughout the term of this Agreement. The cost of such insurance shall be included in the Consultant's bid or proposal. Consultant shall not allow any subcontractor to commence work on any subcontract until Consultant has obtained all insurance required herein for the subcontractor(s) and provided evidence to City that such insurance is in effect.

VERIFICATION OF THE REQUIRED INSURANCE SHALL BE SUBMITTED AND MADE PART OF THIS AGREEMENT PRIOR TO EXECUTION. Consultant shall maintain all required insurance listed herein for the duration of this Agreement.

1. Workers’ Compensation.

1.1. General Requirements. Consultant shall, at its sole cost and expense, maintain Statutory Workers’ Compensation Insurance and Employer’s Liability Insurance for any and all persons employed directly or indirectly by Consultant. The Statutory Workers’ Compensation Insurance and Employer’s Liability Insurance shall be provided with limits of not less than $1,000,000 per accident. In the alternative, Consultant may rely on a self-insurance program to meet these requirements, but only if the program of self-insurance complies fully with the provisions of the California Labor Code. Determination of whether a self-insurance program meets the standards of the California Labor Code shall be solely in the discretion of the Contract Administrator.

The Workers’ Compensation policy shall be endorsed with a waiver of subrogation in favor of the entity for all work performed by the Consultant, its employees, agents, and subcontractors.

1.2 Submittal Requirements. To comply with Subsection 4.1, Consultant shall submit the following:
a. Certificate of Liability Insurance in the amounts specified in the section; and
b. Waiver of Subrogation Endorsement as required by the section.

2. Commercial General and Automobile Liability Insurance.

2.1 General Requirements. Consultant, at its own cost and expense, shall maintain commercial general liability insurance for the term of this Agreement in an amount not less than $5,000,000 and automobile liability insurance for the term of this Agreement in an amount not less than $5,000,000 per occurrence, combined single limit coverage for risks associated with the work contemplated by this DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 25 Agreement. An umbrella policy in the amount of an additional $5,000,000 will supplement the policy coverage limits If a Commercial General Liability Insurance or an Automobile Liability form or other form with a general aggregate limit is used, either the general aggregate limit shall apply separately to the work to be performed under this Agreement or the general aggregate limit shall be at least twice the required occurrence limit. Such coverage shall include but shall not be limited to, protection against claims arising from bodily and personal injury, including death resulting therefrom, and damage to property resulting from activities contemplated under this Agreement, including the use of owned and non-owned automobiles.

2.2 Minimum Scope of Coverage. Commercial general coverage shall be at least as broad as Insurance Services Office Commercial General Liability occurrence form CG 0001 (most recent edition) covering comprehensive General Liability on an “occurrence” basis. Automobile coverage shall be at least as broad as Insurance Services Office Automobile Liability form CA 0001, Code 1 (any auto). No endorsement shall be attached limiting the coverage.

2.3 Additional Requirements. Each of the following shall be included in the insurance coverage or added as a certified endorsement to thepolicy:
a. The Insurance shall cover on an occurrence or an accident basis, and not on a claims-made basis.
b. City, its officers, officials, employees, and volunteers are to be covered asadditional insureds as respects: liability arising out of work or operations performed by or on behalf of the Consultant; or automobiles owned, leased, hired, or borrowed by the Consultant.
c. Consultant hereby agrees to waive subrogation which any insurer or contractor may require from vendor by virtue of the payment of any loss.

Consultant agrees to obtain any endorsements that may be necessary to effect this waiver of subrogation.
d. For any claims related to this Agreement or the work hereunder, the Consultant’s insurance coverage shall be primary insurance as respects the City, its officers, officials, employees, and volunteers. Any insurance or self-insurance maintained by the City, its officers, officials, employees, or volunteers shall be excess of the Consultant’s insurance and shall not contribute with it.

2.4 Submittal Requirements. To comply with Subsection 4.2, Consultant shall submit the following:

DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 26 a. Certificate of Liability Insurance in the amounts specified in thesection; b. Additional Insured Endorsement as required by the section; c. Waiver of Subrogation Endorsement as required by the section; and d. Primary Insurance Endorsement as required by the section.

3. Professional Liability Insurance.

3.1 General Requirements. Consultant, at its own cost and expense, shall maintain for the period covered by this Agreement professional liability insurance for licensed professionals performing work pursuant to this Agreement in an amount not less than $1,000,000 covering the licensed professionals’ errors and omissions. Any deductible or self-insured retention shall not exceed $150,000 per claim.

3.2 Claims-Made Limitations. The following provisions shall apply if the professional liability coverage is written on a claims-made form:
a. The retroactive date of the policy must be shown and must be before the date of the Agreement.
b. Insurance must be maintained and evidence of insurance must be provided for at least 5 years after completion of the Agreement or the work, so long as commercially available at reasonable rates. c. If coverage is canceled or not renewed and it is not replaced with another claims-made policy form with a retroactive date that precedes the date of this Agreement, Consultant shall purchase an extended period coverage for a minimum of 5 years after completion of work under thisAgreement. d. A copy of the claim reporting requirements must be submitted to the City for review prior to the commencement of any work under thisAgreement.

3.3 Additional Requirements. A certified endorsement to include contractual liability shall be included in the policy.

3.4 Submittal Requirements. To comply with Subsection 4.3, Consultant shall submit the Certificate of Liability Insurance in the amounts specified in the section.

4. Builders’ Risk Insurance.

4.1 General Requirements. Contractor will cause to be taken out and maintain in the name of the City and the Contractor until final completion and acceptance of the project: All Risk Builder’s Risk Insurance, including but not limited to coverage against DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 27 loss or damage to the project by fire and lightening, extended coverage, vandalism,malicious mischief, flood, earthquake, and collapse; said extended coverage shall cover loss or damage by explosion, windstorm, riot, aircraft, vehicle damage, smoke, and other such hazards as are normally covered by such coverage. Such insurance (except the earthquakeand flood coverage in the event that they are not fully or reasonably available) shall be in an amount equal to the replacement cost (without deduction for depreciation and subject to stipulated value in lieu of average clause) of all structures constituting any part of the work,excluding the cost of excavations, of grading, and of filling of the land, and except that suchinsurance (except earthquake and flood insurance) may be subject to deductible clauses notto exceed $10,000 for any one loss. Earthquake and flood insurance may be subject to deductible clauses not to exceed five percent (5%) of such replacement cost for any one loss. Such insurance will not cover loss or damage to the Contractor’s equipment, scaffolding, or other materials not to be consumed in the construction of the project. The Contractor shall obtain from the insurer a waiver of subrogation endorsement for losses caused by fire or other perils to the extent covered by this insurance. Contractor shall pay any extra premium required therefore.

5. Environmental Insurance.

5.1 General Requirements. Contractor shall purchase and maintain liability insurancewith coverage, as further specified below, for losses arising from or in any way related to pollution conditions, both sudden and non-sudden (gradual), which arise from or in connection with the Contractor’s transportation services and any disposal facilities used in connection with the underlying Agreement. The required insurance coverage shall be endorsed to cover Non-Owned Disposal Sites. The Contractor’s insurance shall include:

A. Contractors Pollution Liability - limit $3,000,000 per loss and $6,000,000 in the aggregate,
B. Environmental Transportation Liability insurance; provided, however, if the Contractor does not maintain a separate policy evidencing pollution liability coverage in relation to the Contractor’s transportation services, then the Contractor’s CPL insurance policy must be endorsed so as to satisfy the minimum scope of coverage related to the Contractor’s transportation services with limit $3,000,000 per lossand $6,000,000 in the aggregate

6. All Policies Requirements.

6.1 Acceptability of Insurers. All insurance required by this section is to be placed with insurers with a Bests' rating of no less than A:VII.

6.2 Verification of Coverage. Prior to beginning any work under this Agreement, Consultant shall furnish City with complete copies of all Certificates of Liability Insurance delivered to Consultant by the insurer, including complete copies of allendorsements attached to the policies. All copies of Certificates of Liability Insurance and certified endorsements shall show the signature of a person authorized by that insurer to bind coverage on its behalf. If the City does not receive the required insurance documents prior to the Consultant beginning work, DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8 28 it shall not waive the Consultant’s obligation to provide them. The City reserves theright to require complete copies of all required insurance policies at any time.

Deductibles and Self-Insured Retentions. Consultant shall provide a financial guarantee letter satisfactory tothe City guaranteeing payment of retentions and deductibles.

6.3 Wasting Policies. No policy required by this Section 4 shall include a “wasting” policy limit (i.e. limit that is eroded by the cost of defense) except for ProfessionalLiability.

6.4 Endorsement Requirements. Each insurance policy required by Section 4 shall be endorsed to state that coverage shall not be canceled by either party, except after 30 days’ prior written notice has been provided to the City.

6.5 Subcontractors. Consultant shall include all subcontractors as insureds under itspolicies or shall furnish separate certificates and certified endorsements for each subcontractor. All coverages for subcontractors shall be subject to all of the requirements stated herein.

7. Submittal of Proof of Insurance Coverage. All certificates of insurance and original endorsements effecting coverage required in this Section 4 must be electronically submittedthrough the City’s online insurance document management program, PINS Advantage. Contractor shall comply with all requirements provided by City related to the PINS Advantage program.

8. Remedies. In addition to any other remedies City may have if Consultant fails to provide or maintain any insurance policies or policy endorsements to the extent and within the time hereinrequired, City may, at its sole option exercise any of the following remedies, which are alternatives to other remedies City may have and are not the exclusive remedy for Consultant’s breach:
 Obtain such insurance and deduct and retain the amount of the premiums for such insurance from any sums due under the Agreement;
 Order Consultant to stop work under this Agreement or withhold any payment that becomes due to Consultant hereunder, or both stop work and withhold any payment,until Consultant demonstrates compliance with the requirements hereof; and/or
 Terminate this Agreement.
5017729.1
DocuSign Envelope ID: 64BB0189-33AC-48E9-B1D7-D912FB4998D8

← All documents from this meeting