Radio Frequency Safety Survey Report Prediction (RFSSRP) Prepared For:

Site Name: CANC-SLEAN01
FA#: 15521709
USID: 314957
Site ID: CCL05539
Address: 440 Peralta Avenue
San Leandro, CA 94577
County: Alameda
Latitude: 37.7278430
Longitude: -122.1656600
PACE No(s): WSSFR0033466/ WSSFR0052295
Initiatives (s): C-Band/DoD
Additional Site Information
M-RFSC Name: Wesley Rumble
Site Structure Type: Stealth Pole – External Array
Report Information
Report Writer: Jassmine Aldrich Report Generated Date: September 10, 2024 Compliance Statement
AT&T Mobility will be compliant when the remediation recommended in Section 5 or other appropriate remediation determined by AT&T Mobility is implemented.

REGIST ERED

PROFESSIO NA L ENGINEE R
E L E

C T R I C A L
No. E18344

S T A T E O F C A L IFOR NIA
T IM
AL

EXANDER
E L E

C T R I C A L
S T A
NIA
Exp, 31 MAR 2026 SIGNED, 11 SEP 2024
Attachment E - EME Report
S-ORD107114 Page 2
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2024 AT&T Intellectual property. All rights reserved.

Table of Contents
1 General Summary ....................................................................................................... 3

1.1 Site Summary....................................................................................................... 3 2 Site Scale Map............................................................................................................ 4 3 Antenna Inventory ....................................................................................................... 7 4 Predicted Emission Levels and Discussion................................................................. 9

4.1 Predictive AT&T Mobility’s RF Contribution Only on the Site ............................. 10

4.2 Predictive RF Contribution from All Sources on the Site .................................... 14

4.3 Predictive RF Contribution from All Sources at Ground Level ............................ 17

4.4 Predictive RF Contribution from All Sources at 65ft Proposed Building.............. 18 5 Statement of Compliance.......................................................................................... 20

5.1 Statement of AT&T Mobility Compliance ............................................................ 20

5.2 Compliance Requirement Diagram (Access Location) ....................................... 21 6 Appendix A................................................................................................................ 22

6.1 Technical Framework ......................................................................................... 22 7 Appendix B................................................................................................................ 26

7.1 Qualifications of Waterford Consultants, LLC..................................................... 26 8 Appendix C................................................................................................................ 27

8.1 RoofMaster™ ..................................................................................................... 27 9 Appendix D................................................................................................................ 28

9.1 Statement of Limiting Conditions........................................................................ 28 Att E
S-ORD107114 Page 3
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2024 AT&T Intellectual property. All rights reserved. 1 General Summary

1.1 Site Summary
Existing RF Sign(s) at Access Point(s) None
Existing RF Sign(s) at AT&T Mobility Sectors Alpha: None Beta: None
Gamma: None
Existing Barriers at AT&T Mobility Sectors None
Max Predictive Spatial Average MPE% &
Location on Site (General Public) 11860.79% in front of AT&T Mobility Beta Sector Max Predictive Spatial Average MPE% at
Walkable Surface (General Public) 13.13% MPE at 35ft Ramp Level Max Predictive Spatial Average MPE% at
Ground (General Public) 5.58% MPE at 0ft Ground Level
Proposed Number of AT&T Antennas 12
The analysis presented herein is based on the following documents provided by the client:
- Snapshot-RF Issue Preliminary RFDS-1719607878632.pdf
- AE101_CCL05539_15521709_100ZDs_2023-04-25_RevH.pdf
Att E
S-ORD107114 Page 4
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2024 AT&T Intellectual property. All rights reserved. 2 Site Scale Map
Proposed Signs/Barriers Existing Signs/Barriers
Signs Required for Compliance Overall Site (AT&T Mobility Only) Att E
S-ORD107114 Page 5
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2024 AT&T Intellectual property. All rights reserved.

Image to show distance to surrounding buildings
Att E
S-ORD107114 Page 6
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2024 AT&T Intellectual property. All rights reserved.

Image to show Antenna Location
Att E
S-ORD107114 Page 7
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved. 3 Antenna Inventory
Ant # Operator Antenna Make Pattern: Type
Freq
(MHz) Block
Mech/
Elec Az
(deg)
Mech
downtilt
(deg)
Horizontal
Beam
Width
(deg)
Antenna
Length/
Aperture
(ft)
Antenna
Gain
(dBd)
Power
In
(Watts)
ERP
(Watts)
Antenna
Centerline
Ground
Level (0ft)
Bottom of
Antenna
Ground
Level (0ft)
1 AT&T QUINTEL QD6612-3D V1 Panel 700 B12 65 0 70 6 12.07 160 2577.03 71 68 1 AT&T QUINTEL QD6612-3D V1 Panel 850 B5 65 0 64 6 12.37 160 2761.34 71 68 1 AT&T QUINTEL QD6612-3D V1 Panel 1900 B2 65 0 65 6 15.24 160 5347.12 71 68 1 AT&T QUINTEL QD6612-3D V1 Panel 2100 B66 65 0 62 6 15.67 160 5903.64 71 68 2 AT&T ERICSSON SON_AIR6449 NR TB 05.17.22 3700 AT&T Panel 3700 N77D 65 0 11.7 2.8 23.45 108.4 23998.80 69 67.6 3 AT&T ERICSSON SON_AIR6419 NR TB 05.17.22 3700 AT&T Panel 3500 N77G 65 0 13 2.6 23.45 54.2 11999.40 73 71.8 4 AT&T QUINTEL QD6616-7 V1 Panel 700 B14 65 0 66 6 11.97 160 2518.37 71 68 4 AT&T QUINTEL QD6616-7 V1 Panel 700 B29 65 0 66 6 11.97 80 1259.19 71 688 4 AT&T QUINTEL QD6616-7 V2 Panel 2300 B30 65 0 58 6 16.34 100 4305.26 71 68 5 AT&T QUINTEL QD6612-3D V1 Panel 700 B12 270 0 70 6 12.07 160 2577.03 71 68 5 AT&T QUINTEL QD6612-3D V1 Panel 850 B5 270 0 64 6 12.37 160 2761.34 71 68 5 AT&T QUINTEL QD6612-3D V1 Panel 1900 B2 270 0 65 6 15.24 160 5347.12 71 68 5 AT&T QUINTEL QD6612-3D V1 Panel 2100 B66 270 0 62 6 15.67 160 5903.64 71 68 6 AT&T ERICSSON SON_AIR6449 NR TB 05.17.22 3700 AT&T Panel 3700 N77D 270 0 11.7 2.8 23.45 108.4 23998.80 69 67.6 7 AT&T ERICSSON SON_AIR6419 NR TB 05.17.22 3700 AT&T Panel 3500 N77G 270 0 13 2.6 23.45 54.2 11999.40 73 71.8 8 AT&T QUINTEL QD6616-7 V1 Panel 700 B14 270 0 66 6 11.97 160 2518.37 71 68 8 AT&T QUINTEL QD6616-7 V1 Panel 700 B29 270 0 66 6 11.97 80 1259.19 71 688 8 AT&T QUINTEL QD6616-7 V2 Panel 2300 B30 270 0 58 6 16.34 100 4305.26 71 68 9 AT&T QUINTEL QD6612-3D V1 Panel 700 B12 170 0 70 6 12.07 160 2577.03 71 68 9 AT&T QUINTEL QD6612-3D V1 Panel 850 B5 170 0 64 6 12.37 160 2761.34 71 68 9 AT&T QUINTEL QD6612-3D V1 Panel 1900 B2 170 0 65 6 15.24 160 5347.12 71 68 9 AT&T QUINTEL QD6612-3D V1 Panel 2100 B66 170 0 62 6 15.67 160 5903.64 71 68 10 AT&T ERICSSON SON_AIR6449 NR TB 05.17.22 3700 AT&T Panel 3700 N77D 170 0 11.7 2.8 23.45 108.4 23998.80 69 67.6 11 AT&T ERICSSON SON_AIR6419 NR TB 05.17.22 3700 AT&T Panel 3500 N77G 170 0 13 2.6 23.45 54.2 11999.40 73 71.8 12 AT&T QUINTEL QD6616-7 V1 Panel 700 B14 170 0 66 6 11.97 160 2518.37 71 68 12 AT&T QUINTEL QD6616-7 V1 Panel 700 B29 170 0 66 6 11.97 80 1259.19 71 688 12 AT&T QUINTEL QD6616-7 V2 Panel 2300 B30 170 0 58 6 16.34 100 4305.26 71 68 13 Unknown COMMSCOPE NHH-65B-R2B Panel 700 B13 0 0 65 6 12.3 160 2717 59 56 14 Unknown COMMSCOPE NHH-65B-R2B Panel 1900 B2 0 0 69 6 15.7 160 5945 59 56 15 Unknown COMMSCOPE NHH-65B-R2B Panel 2100 B66A 0 0 64 6 16.2 160 6670 59 56 16 Unknown COMMSCOPE NHH-65B-R2B Panel 700 B13 0 0 65 6 12.3 160 2717 59 56 17 Unknown COMMSCOPE NHH-65B-R2B Panel 700 B13 120 0 65 6 12.3 160 2717 59 56 18 Unknown COMMSCOPE NHH-65B-R2B Panel 1900 B2 120 0 69 6 15.7 160 5945 59 56 19 Unknown COMMSCOPE NHH-65B-R2B Panel 2100 B66A 120 0 64 6 16.2 160 6670 59 56 20 Unknown COMMSCOPE NHH-65B-R2B Panel 700 B13 120 0 65 6 12.3 160 2717 59 56 Att E
S-ORD107114 Page 8
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

Ant # Operator Antenna Make Pattern: Type
Freq
(MHz) Block
Mech/
Elec Az
(deg)
Mech
downtilt
(deg)
Horizontal
Beam
Width
(deg)
Antenna
Length/
Aperture
(ft)
Antenna
Gain
(dBd)
Power
In
(Watts)
ERP
(Watts)
Antenna
Centerline
Ground
Level (0ft)
Bottom of
Antenna
Ground
Level (0ft)
21 Unknown COMMSCOPE NHH-65B-R2B Panel 700 B13 240 0 65 6 12.3 160 2717 59 56 22 Unknown COMMSCOPE NHH-65B-R2B Panel 1900 B2 240 0 69 6 15.7 160 5945 59 56 23 Unknown COMMSCOPE NHH-65B-R2B Panel 2100 B66A 240 0 64 6 16.2 160 6670 59 56 24 Unknown COMMSCOPE NHH-65B-R2B Panel 700 B13 240 0 65 6 12.3 160 2717 59 56 25 Unknown RFS APXV9ERR18-C Panel 850 B5 0 0 80 6 11.9 100 1531 47 44 25 Unknown RFS APXV9ERR18-C Panel 190 B25 0 0 80 6 14.6 180 5132 47 44 26 Unknown RFS APXVTM14-ALU-I20 Panel 2500 B41 0 0 65 4.7 15.9 160 6153 47 44 27 Unknown RFS APXV9ERR18-C Panel 850 B5 0 0 80 6 11.9 100 1531 47 44 27 Unknown RFS APXV9ERR18-C Panel 190 B25 0 0 80 6 14.6 180 5132 47 44 28 Unknown RFS APXVTM14-ALU-I20 Panel 2500 B41 0 0 65 4.7 15.9 160 6153 47 44 29 Unknown RFS APXV9ERR18-C Panel 850 B5 120 0 80 6 11.9 100 1531 47 44 29 Unknown RFS APXV9ERR18-C Panel 190 B25 120 0 80 6 14.6 180 5132 47 44 30 Unknown RFS APXVTM14-ALU-I20 Panel 2500 B41 120 0 65 4.7 15.9 160 6153 47 44 31 Unknown RFS APXV9ERR18-C Panel 850 B5 120 0 80 6 11.9 100 1531 47 44 31 Unknown RFS APXV9ERR18-C Panel 190 B25 120 0 80 6 14.6 180 5132 47 44 32 Unknown RFS APXVTM14-ALU-I20 Panel 2500 B41 120 0 65 4.7 15.9 160 6153 47 44 33 Unknown RFS APXV9ERR18-C Panel 850 B5 120 0 80 6 11.9 100 1531 47 44 33 Unknown RFS APXV9ERR18-C Panel 190 B25 120 0 80 6 14.6 180 5132 47 44 34 Unknown RFS APXVTM14-ALU-I20 Panel 2500 B41 120 0 65 4.7 15.9 160 6153 47 44 35 Unknown RFS APXV9ERR18-C Panel 850 B5 120 0 80 6 11.9 100 1531 47 44 35 Unknown RFS APXV9ERR18-C Panel 190 B25 120 0 80 6 14.6 180 5132 47 44 36 Unknown RFS APXVTM14-ALU-I20 Panel 2500 B41 120 0 65 4.7 15.9 160 6153 47 44 37 Unknown ANDREW VHLP2-18 Microwave 18000 0 0 2.1 2 37 0.2 990 37 36 37 Unknown ANDREW VHLP2-18 Microwave 18000 180 0 2.1 2 37 0.2 990 37 36 Note: Waterford Consultants, LLC has assumed transmission parameters for Unknown RF emitters based on similar installations found at other radio communications sites. Generic antenna models have been used where existing antenna part numbers or radiation patterns are not available. The frequencies presented in this table may have been assumed in order to represent the approximate band of operation and to support a worst-case calculation of power density.

Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 9
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved. 4 Predicted Emission Levels and Discussion
The following plots show the spatial average predicted power density levels in the reference plane indicated as a percentage of the General Public Limits. Please note that 100% of the General Public Limits corresponds to 20% of the Occupational Limits.

The reference plane for the plot is the roof level, as indicated in the caption. For example, “Avg 10 to 16 Feet” refers to the spatial average predicted power density level between 10 and 16 feet above the main level. Plots are produced for each accessible level. Levels that are not accessible will not be shown. Only accessible areas in a plot are relevant. Areas not accessible or in free space, off the edge of a roof or equipment penthouse, do not affect compliance.

Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 10
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

4.1 Predictive AT&T Mobility’s RF Contribution Only on the Site Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 11
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 12
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 13
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved. 80ft 80ft
Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 14
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

4.2 Predictive RF Contribution from All Sources on the Site Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 15
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 16
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved. 80ft
80ft 80ft
80ft
65ft 65ft
Att D
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 17
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

4.3 Predictive RF Contribution from All Sources at Ground Level Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 18
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

4.4 Predictive RF Contribution from All Sources at 65ft Proposed Building 133t
100ft
Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 19
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 20
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved. 5 Statement of Compliance

5.1 Statement of AT&T Mobility Compliance
At the time of our assessment, AT&T Mobility is required to take action to comply with FCC Radiofrequency Radiation Exposure Limits.

Att E
Site Name: CANC-SLEAN01
Site FA: 15521709
S-ORD107114 Page 21
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

5.2 Compliance Requirement Diagram (Access Location)
Recommendations
AT&T Mobility Access Location
Caution 2B sign posted 9ft above
ground level at the base of the
tower
Materials –
[1] Caution 2B Sign
Proposed Signs/Barriers Existing Signs/Barriers
Att E
S-ORD107114 Page 22
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved. 6 Appendix A

6.1 Technical Framework
The FCC requires licensees to ensure that persons are not exposed to radiofrequency electromagnetic energy power densities in excess of the applicable MPE (Maximum Permissible Exposure) limits. These rules apply to both Occupational Personnel and the General Population. Applicable FCC rules are found at 47 C.F.R. § § 1.1307(b)(3) and 1.1310. The FCC rules define two tiers of permissible exposure differentiated by the situation in which the exposure takes place and/or the status of the individuals who are subject to exposure.

General Population / uncontrolled exposure limits apply to those situations in which persons may not be aware of the presence of electromagnetic energy, where exposure is not employment-related, or where persons cannot exercise control over their exposure.

Occupational / controlled exposure limits apply to situations in which persons are exposed as a consequence of their employment, have been made fully aware of the potential for exposure, and can exercise control over their exposure.

Maximum Permissible Exposure (“MPE”) is defined in OET 65 as being 100% of the exposure limits for the situation or tier of permissible exposure. These limits are listed as follows:

Limits for Occupational/Controlled Exposure
Frequency
Range (MHz)
Electric
Field
Strength (E)
(V/m)
Magnetic
Field (H)
(A/m)
Power
Density (S)
(mW/cm2)
Averaging Time
|E|2, |H|2 or S
(minutes)

0.3-3.0 614 1.63 (100)* 6

3.0-30 1842/f 4.89/f (900/f2)* 6
30-300 61.5 0.163 1.0 6
300-1500 -- f/300 6
1500-100,000 -- 5 6
Limits for General Population/Uncontrolled Exposure
Frequency
Range (MHz)
Electric
Field
Strength (E)
(V/m)
Magnetic
Field (H)
(A/m)
Power
Density (S)
(mW/cm2)
Averaging Time
|E|2, |H|2 or S
(minutes)

0.3-1.34 614 1.63 (100)* 30

1.34-30 842/f 2.19/f (180/f2)* 30
30-300 27.5 0.073 0.2 30
300-1500 -- f/1500 30
1500-100,000 -- 1.0 30
f = frequency in MHz *Plane-wave equivalent power density Att E
S-ORD107114 Page 23
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

FCC Limits for Maximum Permissible Exposure (MPE)
Plane-wave Equivalent Power Density
For any area in excess of 100% General Population MPE, access controls with appropriate RF alerting signage must be put in place and maintained to restrict access to authorized personnel. Subject to other site security requirements, Occupational Personnel trained in RF safety and equipped with personal protective equipment designed for safe work in the vicinity of RF may be granted access. Controls such as physical barriers to entry imposed by locked doors, locked passageways, or other access control mechanisms may be supplemented by alarms that alert the individual and notify site management of a breach in access control. Controls may include administrative policies and procedures requiring personal protective equipment (e.g.

RF personal monitor), proof of RF training to obtain site access cards, presentation of appropriate RF awareness training certifications to security personnel or other measures designed to prevent uncontrolled access.

Att E
S-ORD107114 Page 24
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

The signs below are examples of signs meeting FCC guidelines.

Att E
S-ORD107114 Page 25
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved.

FCC regulations regarding Radiofrequency radiation exposure, expressed in 47 CFR § 1.1310 are further clarified with respect to the value of 5% of exposure limits for the subject transmitters in the following section of 47 CFR § 1.1307 (b):
(3) In general, when the guidelines specified in § 1.1310 are exceeded in an accessible area due to the emissions from multiple fixed transmitters, actions necessary to bring the area into compliance are the shared responsibility of all licensees whose transmitters produce, at the area in question, power density levels that exceed 5% of the power density exposure limit applicable to their particular transmitter or field strength levels that, when squared, exceed 5% of the square of the electric or magnetic field strength limit applicable to their particular transmitter. Owners of transmitter sites are expected to allow applicants and licensees to take reasonable steps to comply with the requirements contained In § 1.1307(b) and, where feasible, should encourage co-location of transmitters and common solutions for controlling access to areas where the RF exposure limits contained in § 1.1310 might be exceeded.

Following these FCC requirements, predictive modeling has been performed to evaluate power density resulting from client transmitters as a percentage of the power density MPE limit applicable to their transmitters. These results are presented in Section 4.

The site should be routinely inspected and this or a similar report updated with any changes to the RF environment including:
• Adding new antennas
• Removing of any existing antennas
• Change in the radiating power or number of RF emitters Waterford Consultants, LLC recommends coordinating with all wireless tenants before performing services in front of or near any transmitting antennas. During these activities, it may be appropriate to utilize Lockout/Tagout Procedures as specified in ATT-002-290-078, “RF Exposure: Responsibilities, Procedures & Guidelines” for scheduled outages to eliminate RF hazards during these activities.

Att E
S-ORD107114 Page 26
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved. 7 Appendix B

7.1 Qualifications of Waterford Consultants, LLC
Waterford Consultants, LLC [Waterford] provides technical consulting services to clients in the Radio Communications and antenna locating industry. Waterford retains professional engineers who are placed in responsible charge of the processes for analysis.

Waterford is familiar with 47 C.F.R. § § 1.1307(b)(3) and 1.1310 along with the general Rules, Regulations and policies of the FCC. Waterford work processes incorporate all specifications of FCC Office of Engineering and Technology, Bulletin 65 (“OET65”), from the website: www.fcc.gov/oet/rfsafety and follow criteria detailed in 47 CFR §

1.1310 “Radiofrequency Radiation Exposure Limits”.

Within the technical and regulatory framework detailed above, Waterford developed tools according to recognized and generally accepted good engineering practices. Permissible exposure limits are band specific, and the Waterford computerized modeling tools correctly calculate permissible exposure based on the band(s) specified in the input data. Only clients and client representatives are authorized to provide input data through the Waterford web portal. In securing that authorization, clients and client representatives attest to the accuracy of all input data.

Waterford Consultants, LLC attests to the accuracy of the engineering calculations computed by those modeling tools. Furthermore, Waterford attests that the results of those engineering calculations are correctly summarized in this report.

Att E
S-ORD107114 Page 27
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved. 8 Appendix C

8.1 RoofMaster™
RoofMaster™ is the software package that Waterford Consultants, LLC created to model RF environments associated with multiple emitters where the potential exists for human exposure. Based on the computational guidelines set forth in OET Bulletin 65 from the Federal Communications Commission (FCC), RoofMaster™ considers the operating parameters of specified RF sources to predict the overall Maximum Permissible Exposure possible at a given location. These theoretical results represent worst-case predictions as emitters are assumed to be operating at 100% duty cycle.

From the FCC document:
“The revised OET Bulletin 65 has been prepared to provide assistance in determining whether proposed or existing transmitting facilities, operations or devices comply with limits for human exposure to radiofrequency (RF) fields adopted by the Federal Communications Commission (FCC). The bulletin offers guidelines and suggestions for evaluating compliance.” http://transition.fcc.gov/Bureaus/Engineering_Technology/Documents/bulletins/oet65/oet65.pdf Att E
S-ORD107114 Page 28
AT&T Proprietary (Internal use only). Not for use or disclosure outside the AT&T companies, except under written agreement. ©2023 AT&T Intellectual property. All rights reserved. 9 Appendix D

9.1 Statement of Limiting Conditions
Waterford Consultants, LLC has received data pertaining to RF environment provided by the client. Waterford Consultants, LLC will not be responsible for matters of a legal nature that affect the site or property. The property has been analyzed under the premise that it is under responsible ownership and management and our client has the legal right to conduct business at this facility.

Due to the complexity of some wireless sites, Waterford Consultants, LLC has created this report utilizing best industry practices and due diligence. Waterford Consultants, LLC cannot be held accountable or responsible for anomalies or discrepancies due to actual site conditions (i.e., mislabelling of antennas or equipment, inaccessible cable runs, inaccessible antennas or equipment, etc.) or information or data supplied by Wireless Carrier, the site manager, or their affiliates, subcontractors or assigns.

Waterford Consultants, LLC has provided the results of a computer generated model in this MPE Site Compliance Report to show approximate dimensions of the site, and the model results is included to assist the reader of the compliance report to visualize the site area, and to provide supporting documentation for Waterford Consultants, LLC recommendations.

Waterford Consultants, LLC will not be responsible for any existing conditions or for any engineering or testing that might be required to discover whether adverse safety conditions exist. Because Waterford Consultants, LLC is not an expert in the field of mechanical engineering or building maintenance, this MPE Site Compliance Report must not be considered a structural or physical engineering report.

Waterford Consultants, LLC obtained information used in this MPE Site Compliance Report from sources that Waterford Consultants, LLC considers reliable and believes them to be true and correct. Waterford Consultants, LLC does not assume any responsibility for the accuracy of such items that were furnished by other parties.

Att E