Attachment D
Station Floor Layouts
USDD.CA_SNLO.FS09.FSA.DWG design by

A B C D
4 3
2 1
4 2
1 A B C D
3 project building filename date

T H I S D O C U M E N T CONTAINS CONFIDENTIAL A N D P R O P R I E T A R Y

INFORMATION WHICH IS

THE EXCLUSIVE PROPERTY OF US DIGITAL DESIGNS,
I N C . R EP R O D U C T I O N , DISTRIBUTION OR USE BY OTHERS, IN WHOLE OR IN

PART, IS NOT PERMITTED WITHOUT THE WRITTEN
AUTHORIZATION FROM US DIGITAL DESIGNS, INC.

PoE = G2 ATX Power-over-Ethernet (PoE) ports 1...8 and G2 Expansion Module ports 1...12 A.n = G2 ATX Amplifier 1...4 EA.n = G2 External Amplifier 1...n CH.n = G2 Message Remote 2 Channel 1 or 2 2/16/2024 - 10:03AM

SYMBOL DESCRIPTION
G2 I/O REMOTE

PUSH BUTTON - RED
G2 STROBE LIGHT

SPEAKER, WEATHER-PROOF SPEAKER, FLUSH MOUNT SPEAKER, METAL BOX G2 LED SPEAKER, FLUSH MOUNT G2 LED SPEAKER, METAL BOX

OEM TRANSFORMER
G2 HDTV REMOTE G2 COLOR

INDICATOR REMOTE
OEM FLAT PANEL MONITOR, XX", WITH MOUNT
G2 MESSAGE SIGN
(STANDARD 24")

VOLUME CONTROL
(CUSTOMER SUPPLIED)
G2 ROOM REMOTE 2

ARTICULATING ARM

MOUNT - LONG

ADAPTER PLATE DOUBLE

PUSH BUTTON - BLACK
G2 OMNIALERT STROBE SPEAKER
G2 MESSAGE SIGN
(MINI 12") G2 MESSAGE SIGN
(EXTENDED 36")

ADAPTER PLATE
SINGLE
G2 MESSAGE REMOTE 2
G2 ATX
STATION CONTROLLER G2 EXPANSION MODULE G2-UNINTERRUPTIBLE

POWER SUPPLY OEM AMPLIFIER

SYMBOL DESCRIPTION
TVR
PB

BLACK PB

RED CIR
STR
ATX
I/O
T
UPS
AMP
MR2
EXP
RR2
S
S
S
ADS
MSE
MSML
MSS
MSM
VC
S
S
ADP
MSML
S
LAR
G2 LOCAL AREA REMOTE
FPD MOUNT FPM - XX" address

END-USER APPROVES STATION
DESIGN FOR PURPOSES OF OBTAINING QUOTE.

INSTALLER CONFIRMS DESIGN
ALIGNS WITH SITE CONDITIONS. (SPEAKER MOUNTING TYPE, ATX LOCATION ETC.)

SIGNATURE REQUIRED
G2 VIDEO DOOR

STATION
VDS SAN LEANDRO FD, CA (ALAMEDA COUNTY) ACFFS09 450 ESTUDILLO AVE SAN LEANDRO DWK NOTES:

1. SEE ARCHITECTURAL SPECIFICATIONS FOR ALL ROUGH-IN AND INSTALLATION DETAILS.

2. US DIGITAL DESIGNS DOES NOT SUPPLY BACK BOXES, CONDUITS, OR MOUNTING FASTENERS.

3. PHOENIX G2 SYSTEM IS ABLE TO SIGNAL OWNER-FURBISHED SYSTEMS, (EXHAUST, LIGHT, GAS SHUT OFF, ETC.) BUT USDD DOES NOT SUPPLY THESE SYSTEMS AND CANNOT WARRANT OR SUPPORT ANY OF THEIR PERFORMANCE BEYOND THE TRANSMISSION OF RELAY SIGNAL TO THEM.

4. US DIGITAL DESIGNS FIRE STATION ALERTING PLANS ARE DIAGRAMMATIC AND FOR QUOTING PURPOSES ONLY. DRAWING MAY NOT BE TO SCALE.

INSTALLER NOTES:

1. INSTALLER TO VERIFY WALL AND CEILING TYPE TO DETERMINE NEED FOR FLUSH OR SURFACE MOUNT INSTALLATION OF EQUIPMENT SPECIFIED.

2. INSTALLER TO COORDINATE CONNECTION BETWEEN ATX STATION CONTROLLER’S LINE-LEVEL AUDIO OUTPUT AND (EXISTING) OWNER-FURBISHED HOUSE AUDIO SYSTEM (AMP). (IF APPLICABLE)

3. INSTALLER TO PROVIDE CAT6 & 18/4 CABLES FROM ATX CONTROLLER TO CUSTOMER'S STATION RADIO FOR BACKUP.

4. INSTALLER TO PROVIDE CAT6 CABLE FROM ATX CONTROLLER WAN OUTPUT TO CUSTOMER'S IN-STATION NETWORK.

5. INSTALLER TO COORDINATE CONNECTION BETWEEN EXISTING STATION LIGHTING CONTROL SYSTEM AND RELAY OUTPUT FROM ATX STATION CONTROLLER OR I/O REMOTE WITH OWNER. (IF APPLICABLE)

6. VOLUME CONTROL TO BE PROVIDED BY OWNER OR INSTALLER IF SHOWN ON DRAWING.

7. INSTALLER TO VERIFY AND CONSIDER LOCATION(S) OF NETWORK AND RADIO CONNECTIONS.

S
TO MR2 BY ATX
PB

RED EMERGENCY ALERT PB

RED EMERGENCY ALERT
PB

RED EMERGENCY ALERT PB

RED EMERGENCY ALERT ADP MSML MSS MSS
PoE TVR

TO ATX SWITCH ONLY CIR
PoE
STR

TO ATX SWITCH ONLY
TVR
RR2 PoE
RR2 PoE
A.2 A.1
A.1
A.3 S
S S
S S
S
S
S
S
S
S S
S
S
S
S
S
A.4

VDS VIDEO DOORBELL
ATX
UPS
MR2 MR2-A PoE
Count Name
1 G2 ATX STATION CONTROLLER
1 G2 COLOR INDICATOR REMOTE
2 G2 HDTV REMOTE
16 G2 LED SPEAKER (G2-LVL-HC-70)
1 G2 MESSAGE REMOTE 2
2 G2 MESSAGE SIGN STANDARD (MS-G2-S)
1 G2 MS ADAPTOR PLATE DOUBLE (AP-D)
1 G2 OMNISTROBE SPEAKER
1 G2 STROBE LIGHT
1 G2 UPS (G2-UPS)
1 MS-MNT-ART-L
4 PUSH BUTTON (RED)
2 ROOM REMOTE 2 (RR-2)
1 SPEAKER WEATHER-PROOF
1 VIDEO DOOR STATION
Count Name
5 G2 PoE PORT REQUIRED
USDD.CA_SNLO.FS10.FSA.DWG design by

A B C D
4 3
2 1
4 2
1 A B C D
3 project building filename date

T H I S D O C U M E N T CONTAINS CONFIDENTIAL A N D P R O P R I E T A R Y

INFORMATION WHICH IS

THE EXCLUSIVE PROPERTY OF US DIGITAL DESIGNS,
I N C . R EP R O D U C T I O N , DISTRIBUTION OR USE BY OTHERS, IN WHOLE OR IN

PART, IS NOT PERMITTED WITHOUT THE WRITTEN
AUTHORIZATION FROM US DIGITAL DESIGNS, INC.

PoE = G2 ATX Power-over-Ethernet (PoE) ports 1...8 and G2 Expansion Module ports 1...12 A.n = G2 ATX Amplifier 1...4 EA.n = G2 External Amplifier 1...n CH.n = G2 Message Remote 2 Channel 1 or 2 2/16/2024 - 10:03AM

SYMBOL DESCRIPTION
G2 I/O REMOTE

PUSH BUTTON - RED
G2 STROBE LIGHT

SPEAKER, WEATHER-PROOF SPEAKER, FLUSH MOUNT SPEAKER, METAL BOX G2 LED SPEAKER, FLUSH MOUNT G2 LED SPEAKER, METAL BOX

OEM TRANSFORMER
G2 HDTV REMOTE G2 COLOR

INDICATOR REMOTE
OEM FLAT PANEL MONITOR, XX", WITH MOUNT
G2 MESSAGE SIGN
(STANDARD 24")

VOLUME CONTROL
(CUSTOMER SUPPLIED)
G2 ROOM REMOTE 2

ARTICULATING ARM

MOUNT - LONG

ADAPTER PLATE DOUBLE

PUSH BUTTON - BLACK
G2 OMNIALERT STROBE SPEAKER
G2 MESSAGE SIGN
(MINI 12") G2 MESSAGE SIGN
(EXTENDED 36")

ADAPTER PLATE
SINGLE
G2 MESSAGE REMOTE 2
G2 ATX
STATION CONTROLLER G2 EXPANSION MODULE G2-UNINTERRUPTIBLE

POWER SUPPLY OEM AMPLIFIER

SYMBOL DESCRIPTION
TVR
PB

BLACK PB

RED CIR
STR
ATX
I/O
T
UPS
AMP
MR2
EXP
RR2
S
S
S
ADS
MSE
MSML
MSS
MSM
VC
S
S
ADP
MSML
S
LAR
G2 LOCAL AREA REMOTE
FPD MOUNT FPM - XX" address

END-USER APPROVES STATION
DESIGN FOR PURPOSES OF OBTAINING QUOTE.

INSTALLER CONFIRMS DESIGN
ALIGNS WITH SITE CONDITIONS. (SPEAKER MOUNTING TYPE, ATX LOCATION ETC.)

SIGNATURE REQUIRED
G2 VIDEO DOOR

STATION
VDS SAN LEANDRO FD, CA (ALAMEDA COUNTY) ACFFS10 2194 WILLIAMS ST. SAN LEANDRO DWK NOTES:

1. SEE ARCHITECTURAL SPECIFICATIONS FOR ALL ROUGH-IN AND INSTALLATION DETAILS.

2. US DIGITAL DESIGNS DOES NOT SUPPLY BACK BOXES, CONDUITS, OR MOUNTING FASTENERS.

3. PHOENIX G2 SYSTEM IS ABLE TO SIGNAL OWNER-FURBISHED SYSTEMS, (EXHAUST, LIGHT, GAS SHUT OFF, ETC.) BUT USDD DOES NOT SUPPLY THESE SYSTEMS AND CANNOT WARRANT OR SUPPORT ANY OF THEIR PERFORMANCE BEYOND THE TRANSMISSION OF RELAY SIGNAL TO THEM.

4. US DIGITAL DESIGNS FIRE STATION ALERTING PLANS ARE DIAGRAMMATIC AND FOR QUOTING PURPOSES ONLY. DRAWING MAY NOT BE TO SCALE.

INSTALLER NOTES:

1. INSTALLER TO VERIFY WALL AND CEILING TYPE TO DETERMINE NEED FOR FLUSH OR SURFACE MOUNT INSTALLATION OF EQUIPMENT SPECIFIED.

2. INSTALLER TO COORDINATE CONNECTION BETWEEN ATX STATION CONTROLLER’S LINE-LEVEL AUDIO OUTPUT AND (EXISTING) OWNER-FURBISHED HOUSE AUDIO SYSTEM (AMP). (IF APPLICABLE)

3. INSTALLER TO PROVIDE CAT6 & 18/4 CABLES FROM ATX CONTROLLER TO CUSTOMER'S STATION RADIO FOR BACKUP.

4. INSTALLER TO PROVIDE CAT6 CABLE FROM ATX CONTROLLER WAN OUTPUT TO CUSTOMER'S IN-STATION NETWORK.

5. INSTALLER TO COORDINATE CONNECTION BETWEEN EXISTING STATION LIGHTING CONTROL SYSTEM AND RELAY OUTPUT FROM ATX STATION CONTROLLER OR I/O REMOTE WITH OWNER. (IF APPLICABLE)

6. VOLUME CONTROL TO BE PROVIDED BY OWNER OR INSTALLER IF SHOWN ON DRAWING.

7. INSTALLER TO VERIFY AND CONSIDER LOCATION(S) OF NETWORK AND RADIO CONNECTIONS.

ADP

MSML MSS
MSS
PoE PB

RED EMERGENCY ALERT S
A.4
TVR

TO ATX SWITCH ONLY
PoE CIR

VDS VIDEO DOORBELL
PB

RED EMERGENCY ALERT

EMERGENCY ALERT PB
RED S
TO MR2 BY ATX RR2
PoE
PoE CIR TVR

TO ATX SWITCH ONLY STR
ATX
UPS
MR2 MR2-A PoE
A.3 A.2
A.1
S
S
S
S S S
S S
S
S S
S
S
S
S
S S
S
S S
S S S
S
S
A.1
Count Name
1 G2 ATX STATION CONTROLLER
2 G2 COLOR INDICATOR REMOTE
2 G2 HDTV REMOTE
25 G2 LED SPEAKER (G2-LVL-HC-70)
1 G2 MESSAGE REMOTE 2
2 G2 MESSAGE SIGN STANDARD (MS-G2-S)
1 G2 MS ADAPTOR PLATE DOUBLE (AP-D)
1 G2 OMNISTROBE SPEAKER
1 G2 STROBE LIGHT
1 G2 UPS (G2-UPS)
1 MS-MNT-ART-L
3 PUSH BUTTON (RED)
1 ROOM REMOTE 2 (RR-2)
1 SPEAKER WEATHER-PROOF
1 VIDEO DOOR STATION
Count Name
5 G2 PoE PORT REQUIRED
USDD.CA_SNLO.FS11.FSA.DWG design by

A B C D
4 3
2 1
4 2
1 A B C D
3 project building filename date

T H I S D O C U M E N T CONTAINS CONFIDENTIAL A N D P R O P R I E T A R Y

INFORMATION WHICH IS

THE EXCLUSIVE PROPERTY OF US DIGITAL DESIGNS,
I N C . R EP R O D U C T I O N , DISTRIBUTION OR USE BY OTHERS, IN WHOLE OR IN

PART, IS NOT PERMITTED WITHOUT THE WRITTEN
AUTHORIZATION FROM US DIGITAL DESIGNS, INC.

PoE = G2 ATX Power-over-Ethernet (PoE) ports 1...8 and G2 Expansion Module ports 1...12 A.n = G2 ATX Amplifier 1...4 EA.n = G2 External Amplifier 1...n CH.n = G2 Message Remote 2 Channel 1 or 2 2/16/2024 - 10:04AM

SYMBOL DESCRIPTION
G2 I/O REMOTE

PUSH BUTTON - RED
G2 STROBE LIGHT

SPEAKER, WEATHER-PROOF SPEAKER, FLUSH MOUNT SPEAKER, METAL BOX G2 LED SPEAKER, FLUSH MOUNT G2 LED SPEAKER, METAL BOX

OEM TRANSFORMER
G2 HDTV REMOTE G2 COLOR

INDICATOR REMOTE
OEM FLAT PANEL MONITOR, XX", WITH MOUNT
G2 MESSAGE SIGN
(STANDARD 24")

VOLUME CONTROL
(CUSTOMER SUPPLIED)
G2 ROOM REMOTE 2

ARTICULATING ARM

MOUNT - LONG

ADAPTER PLATE DOUBLE

PUSH BUTTON - BLACK
G2 OMNIALERT STROBE SPEAKER
G2 MESSAGE SIGN
(MINI 12") G2 MESSAGE SIGN
(EXTENDED 36")

ADAPTER PLATE
SINGLE
G2 MESSAGE REMOTE 2
G2 ATX
STATION CONTROLLER G2 EXPANSION MODULE G2-UNINTERRUPTIBLE

POWER SUPPLY OEM AMPLIFIER

SYMBOL DESCRIPTION
TVR
PB

BLACK PB

RED CIR
STR
ATX
I/O
T
UPS
AMP
MR2
EXP
RR2
S
S
S
ADS
MSE
MSML
MSS
MSM
VC
S
S
ADP
MSML
S
LAR
G2 LOCAL AREA REMOTE
FPD MOUNT FPM - XX" address

END-USER APPROVES STATION
DESIGN FOR PURPOSES OF OBTAINING QUOTE.

INSTALLER CONFIRMS DESIGN
ALIGNS WITH SITE CONDITIONS. (SPEAKER MOUNTING TYPE, ATX LOCATION ETC.)

SIGNATURE REQUIRED
G2 VIDEO DOOR

STATION
VDS SAN LEANDRO FD, CA (ALAMEDA COUNTY) ACFFS11 14903 CATALINA ST. LEANDRO DWK NOTES:

1. SEE ARCHITECTURAL SPECIFICATIONS FOR ALL ROUGH-IN AND INSTALLATION DETAILS.

2. US DIGITAL DESIGNS DOES NOT SUPPLY BACK BOXES, CONDUITS, OR MOUNTING FASTENERS.

3. PHOENIX G2 SYSTEM IS ABLE TO SIGNAL OWNER-FURBISHED SYSTEMS, (EXHAUST, LIGHT, GAS SHUT OFF, ETC.) BUT USDD DOES NOT SUPPLY THESE SYSTEMS AND CANNOT WARRANT OR SUPPORT ANY OF THEIR PERFORMANCE BEYOND THE TRANSMISSION OF RELAY SIGNAL TO THEM.

4. US DIGITAL DESIGNS FIRE STATION ALERTING PLANS ARE DIAGRAMMATIC AND FOR QUOTING PURPOSES ONLY. DRAWING MAY NOT BE TO SCALE.

INSTALLER NOTES:

1. INSTALLER TO VERIFY WALL AND CEILING TYPE TO DETERMINE NEED FOR FLUSH OR SURFACE MOUNT INSTALLATION OF EQUIPMENT SPECIFIED.

2. INSTALLER TO COORDINATE CONNECTION BETWEEN ATX STATION CONTROLLER’S LINE-LEVEL AUDIO OUTPUT AND (EXISTING) OWNER-FURBISHED HOUSE AUDIO SYSTEM (AMP). (IF APPLICABLE)

3. INSTALLER TO PROVIDE CAT6 & 18/4 CABLES FROM ATX CONTROLLER TO CUSTOMER'S STATION RADIO FOR BACKUP.

4. INSTALLER TO PROVIDE CAT6 CABLE FROM ATX CONTROLLER WAN OUTPUT TO CUSTOMER'S IN-STATION NETWORK.

5. INSTALLER TO COORDINATE CONNECTION BETWEEN EXISTING STATION LIGHTING CONTROL SYSTEM AND RELAY OUTPUT FROM ATX STATION CONTROLLER OR I/O REMOTE WITH OWNER. (IF APPLICABLE)

6. VOLUME CONTROL TO BE PROVIDED BY OWNER OR INSTALLER IF SHOWN ON DRAWING.

7. INSTALLER TO VERIFY AND CONSIDER LOCATION(S) OF NETWORK AND RADIO CONNECTIONS.

S
TO MR2 BY ATX
TVR

TO ATX SWITCH ONLY
ADP

MSML MSS
MSS
PoE TVR

TO ATX SWITCH ONLY
PoE CIR
RR2 PoE
PoE CIR

VDS VIDEO DOORBELL
S
A.4
A.1
A.1
A.3 A.2
S
S
S

S S S S
S
S
S
S
S S
S
S S
S
S
S
S S
STR
ATX
UPS
MR2 MR2-A PoE
Count Name
1 G2 ATX STATION CONTROLLER
2 G2 COLOR INDICATOR REMOTE
2 G2 HDTV REMOTE
21 G2 LED SPEAKER (G2-LVL-HC-70)
1 G2 MESSAGE REMOTE 2
2 G2 MESSAGE SIGN STANDARD (MS-G2-S)
1 G2 MS ADAPTOR PLATE DOUBLE (AP-D)
1 G2 OMNISTROBE SPEAKER
1 G2 STROBE LIGHT
1 G2 UPS (G2-UPS)
1 MS-MNT-ART-L
1 ROOM REMOTE 2 (RR-2)
1 SPEAKER WEATHER-PROOF
1 VIDEO DOOR STATION
Count Name
5 G2 PoE PORT REQUIRED
USDD.CA_SNLO.FS12.FSA.DWG design by

A B C D
4 3
2 1
4 2
1 A B C D
3 project building filename date

T H I S D O C U M E N T CONTAINS CONFIDENTIAL A N D P R O P R I E T A R Y

INFORMATION WHICH IS

THE EXCLUSIVE PROPERTY OF US DIGITAL DESIGNS,
I N C . R EP R O D U C T I O N , DISTRIBUTION OR USE BY OTHERS, IN WHOLE OR IN

PART, IS NOT PERMITTED WITHOUT THE WRITTEN
AUTHORIZATION FROM US DIGITAL DESIGNS, INC.

PoE = G2 ATX Power-over-Ethernet (PoE) ports 1...8 and G2 Expansion Module ports 1...12 A.n = G2 ATX Amplifier 1...4 EA.n = G2 External Amplifier 1...n CH.n = G2 Message Remote 2 Channel 1 or 2 2/16/2024 - 10:04AM

SYMBOL DESCRIPTION
G2 I/O REMOTE

PUSH BUTTON - RED
G2 STROBE LIGHT

SPEAKER, WEATHER-PROOF SPEAKER, FLUSH MOUNT SPEAKER, METAL BOX G2 LED SPEAKER, FLUSH MOUNT G2 LED SPEAKER, METAL BOX

OEM TRANSFORMER
G2 HDTV REMOTE G2 COLOR

INDICATOR REMOTE
OEM FLAT PANEL MONITOR, XX", WITH MOUNT
G2 MESSAGE SIGN
(STANDARD 24")

VOLUME CONTROL
(CUSTOMER SUPPLIED)
G2 ROOM REMOTE 2

ARTICULATING ARM

MOUNT - LONG

ADAPTER PLATE DOUBLE

PUSH BUTTON - BLACK
G2 OMNIALERT STROBE SPEAKER
G2 MESSAGE SIGN
(MINI 12") G2 MESSAGE SIGN
(EXTENDED 36")

ADAPTER PLATE
SINGLE
G2 MESSAGE REMOTE 2
G2 ATX
STATION CONTROLLER G2 EXPANSION MODULE G2-UNINTERRUPTIBLE

POWER SUPPLY OEM AMPLIFIER

SYMBOL DESCRIPTION
TVR
PB

BLACK PB

RED CIR
STR
ATX
I/O
T
UPS
AMP
MR2
EXP
RR2
S
S
S
ADS
MSE
MSML
MSS
MSM
VC
S
S
ADP
MSML
S
LAR
G2 LOCAL AREA REMOTE
FPD MOUNT FPM - XX" address

END-USER APPROVES STATION
DESIGN FOR PURPOSES OF OBTAINING QUOTE.

INSTALLER CONFIRMS DESIGN
ALIGNS WITH SITE CONDITIONS. (SPEAKER MOUNTING TYPE, ATX LOCATION ETC.)

SIGNATURE REQUIRED
G2 VIDEO DOOR

STATION
VDS SAN LEANDRO FD, CA (ALAMEDA COUNTY) ACFFS12 1065 143RD AVE SAN LEANDRO DWK NOTES:

1. SEE ARCHITECTURAL SPECIFICATIONS FOR ALL ROUGH-IN AND INSTALLATION DETAILS.

2. US DIGITAL DESIGNS DOES NOT SUPPLY BACK BOXES, CONDUITS, OR MOUNTING FASTENERS.

3. PHOENIX G2 SYSTEM IS ABLE TO SIGNAL OWNER-FURBISHED SYSTEMS, (EXHAUST, LIGHT, GAS SHUT OFF, ETC.) BUT USDD DOES NOT SUPPLY THESE SYSTEMS AND CANNOT WARRANT OR SUPPORT ANY OF THEIR PERFORMANCE BEYOND THE TRANSMISSION OF RELAY SIGNAL TO THEM.

4. US DIGITAL DESIGNS FIRE STATION ALERTING PLANS ARE DIAGRAMMATIC AND FOR QUOTING PURPOSES ONLY. DRAWING MAY NOT BE TO SCALE.

INSTALLER NOTES:

1. INSTALLER TO VERIFY WALL AND CEILING TYPE TO DETERMINE NEED FOR FLUSH OR SURFACE MOUNT INSTALLATION OF EQUIPMENT SPECIFIED.

2. INSTALLER TO COORDINATE CONNECTION BETWEEN ATX STATION CONTROLLER’S LINE-LEVEL AUDIO OUTPUT AND (EXISTING) OWNER-FURBISHED HOUSE AUDIO SYSTEM (AMP). (IF APPLICABLE)

3. INSTALLER TO PROVIDE CAT6 & 18/4 CABLES FROM ATX CONTROLLER TO CUSTOMER'S STATION RADIO FOR BACKUP.

4. INSTALLER TO PROVIDE CAT6 CABLE FROM ATX CONTROLLER WAN OUTPUT TO CUSTOMER'S IN-STATION NETWORK.

5. INSTALLER TO COORDINATE CONNECTION BETWEEN EXISTING STATION LIGHTING CONTROL SYSTEM AND RELAY OUTPUT FROM ATX STATION CONTROLLER OR I/O REMOTE WITH OWNER. (IF APPLICABLE)

6. VOLUME CONTROL TO BE PROVIDED BY OWNER OR INSTALLER IF SHOWN ON DRAWING.

7. INSTALLER TO VERIFY AND CONSIDER LOCATION(S) OF NETWORK AND RADIO CONNECTIONS.

S
TO MR2 BY ATX
ADP

MSML MSS
MSS
PoE
VDS VIDEO DOORBELL RR2 PoE
PB

RED EMERGENCY ALERT
PB

RED EMERGENCY ALERT
PB

RED EMERGENCY ALERT TVR

TO ATX SWITCH ONLY STR TVR

TO ATX SWITCH ONLY
PoE CIR RR2 PoE
S
A.4
A.3
A.3
A.2
A.1
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
S
A.1 S
S
S
ATX
UPS
MR2 MR2-A PoE
Count Name
1 G2 ATX STATION CONTROLLER
2 G2 COLOR INDICATOR REMOTE
2 G2 HDTV REMOTE
28 G2 LED SPEAKER (G2-LVL-HC-70)
1 G2 MESSAGE REMOTE 2
2 G2 MESSAGE SIGN STANDARD (MS-G2-S)
1 G2 MS ADAPTOR PLATE DOUBLE (AP-D)
1 G2 OMNISTROBE SPEAKER
1 G2 STROBE LIGHT
1 G2 UPS (G2-UPS)
1 MS-MNT-ART-L
3 PUSH BUTTON (RED)
2 ROOM REMOTE 2 (RR-2)
1 SPEAKER WEATHER-PROOF
1 VIDEO DOOR STATION
Count Name
6 G2 PoE PORT REQUIRED CIR
PoE
USDD.CA_SNLO.FS13.FSA.DWG design by

A B C D
4 3
2 1
4 2
1 A B C D
3 project building filename date

T H I S D O C U M E N T CONTAINS CONFIDENTIAL A N D P R O P R I E T A R Y

INFORMATION WHICH IS

THE EXCLUSIVE PROPERTY OF US DIGITAL DESIGNS,
I N C . R EP R O D U C T I O N , DISTRIBUTION OR USE BY OTHERS, IN WHOLE OR IN

PART, IS NOT PERMITTED WITHOUT THE WRITTEN
AUTHORIZATION FROM US DIGITAL DESIGNS, INC.

PoE = G2 ATX Power-over-Ethernet (PoE) ports 1...8 and G2 Expansion Module ports 1...12 A.n = G2 ATX Amplifier 1...4 EA.n = G2 External Amplifier 1...n CH.n = G2 Message Remote 2 Channel 1 or 2 2/16/2024 - 10:04AM

SYMBOL DESCRIPTION
G2 I/O REMOTE

PUSH BUTTON - RED
G2 STROBE LIGHT

SPEAKER, WEATHER-PROOF SPEAKER, FLUSH MOUNT SPEAKER, METAL BOX G2 LED SPEAKER, FLUSH MOUNT G2 LED SPEAKER, METAL BOX

OEM TRANSFORMER
G2 HDTV REMOTE G2 COLOR

INDICATOR REMOTE
OEM FLAT PANEL MONITOR, XX", WITH MOUNT
G2 MESSAGE SIGN
(STANDARD 24")

VOLUME CONTROL
(CUSTOMER SUPPLIED)
G2 ROOM REMOTE 2

ARTICULATING ARM

MOUNT - LONG

ADAPTER PLATE DOUBLE

PUSH BUTTON - BLACK
G2 OMNIALERT STROBE SPEAKER
G2 MESSAGE SIGN
(MINI 12") G2 MESSAGE SIGN
(EXTENDED 36")

ADAPTER PLATE
SINGLE
G2 MESSAGE REMOTE 2
G2 ATX
STATION CONTROLLER G2 EXPANSION MODULE G2-UNINTERRUPTIBLE

POWER SUPPLY OEM AMPLIFIER

SYMBOL DESCRIPTION
TVR
PB

BLACK PB

RED CIR
STR
ATX
I/O
T
UPS
AMP
MR2
EXP
RR2
S
S
S
ADS
MSE
MSML
MSS
MSM
VC
S
S
ADP
MSML
S
LAR
G2 LOCAL AREA REMOTE
FPD MOUNT FPM - XX" address

END-USER APPROVES STATION
DESIGN FOR PURPOSES OF OBTAINING QUOTE.

INSTALLER CONFIRMS DESIGN
ALIGNS WITH SITE CONDITIONS. (SPEAKER MOUNTING TYPE, ATX LOCATION ETC.)

SIGNATURE REQUIRED
G2 VIDEO DOOR

STATION
VDS SAN LEANDRO FD, CA (ALAMEDA COUNTY) ACFFS13 637 FARGO AVE SAN LEANDRO DWK NOTES:

1. SEE ARCHITECTURAL SPECIFICATIONS FOR ALL ROUGH-IN AND INSTALLATION DETAILS.

2. US DIGITAL DESIGNS DOES NOT SUPPLY BACK BOXES, CONDUITS, OR MOUNTING FASTENERS.

3. PHOENIX G2 SYSTEM IS ABLE TO SIGNAL OWNER-FURBISHED SYSTEMS, (EXHAUST, LIGHT, GAS SHUT OFF, ETC.) BUT USDD DOES NOT SUPPLY THESE SYSTEMS AND CANNOT WARRANT OR SUPPORT ANY OF THEIR PERFORMANCE BEYOND THE TRANSMISSION OF RELAY SIGNAL TO THEM.

4. US DIGITAL DESIGNS FIRE STATION ALERTING PLANS ARE DIAGRAMMATIC AND FOR QUOTING PURPOSES ONLY. DRAWING MAY NOT BE TO SCALE.

INSTALLER NOTES:

1. INSTALLER TO VERIFY WALL AND CEILING TYPE TO DETERMINE NEED FOR FLUSH OR SURFACE MOUNT INSTALLATION OF EQUIPMENT SPECIFIED.

2. INSTALLER TO COORDINATE CONNECTION BETWEEN ATX STATION CONTROLLER’S LINE-LEVEL AUDIO OUTPUT AND (EXISTING) OWNER-FURBISHED HOUSE AUDIO SYSTEM (AMP). (IF APPLICABLE)

3. INSTALLER TO PROVIDE CAT6 & 18/4 CABLES FROM ATX CONTROLLER TO CUSTOMER'S STATION RADIO FOR BACKUP.

4. INSTALLER TO PROVIDE CAT6 CABLE FROM ATX CONTROLLER WAN OUTPUT TO CUSTOMER'S IN-STATION NETWORK.

5. INSTALLER TO COORDINATE CONNECTION BETWEEN EXISTING STATION LIGHTING CONTROL SYSTEM AND RELAY OUTPUT FROM ATX STATION CONTROLLER OR I/O REMOTE WITH OWNER. (IF APPLICABLE)

6. VOLUME CONTROL TO BE PROVIDED BY OWNER OR INSTALLER IF SHOWN ON DRAWING.

7. INSTALLER TO VERIFY AND CONSIDER LOCATION(S) OF NETWORK AND RADIO CONNECTIONS.

S
TO MR2 BY ATX
ADP

MSML MSS
MSS
PoE
PB

RED EMERGENCY ALERT
PB

RED EMERGENCY ALERT
TVR

TO ATX SWITCH ONLY TVR

TO ATX SWITCH ONLY STR CIR
PoE
ATX
UPS
MR2 MR2-A PoE
S
A.4
A.1
A.3
A.1
A.2
S
S
S
S
S
S
S
S
S
PB

RED EMERGENCY ALERT
Count Name
1 G2 ATX STATION CONTROLLER
1 G2 COLOR INDICATOR REMOTE
2 G2 HDTV REMOTE
9 G2 LED SPEAKER (G2-LVL-HC-70)
1 G2 MESSAGE REMOTE 2
2 G2 MESSAGE SIGN STANDARD (MS-G2-S)
1 G2 MS ADAPTOR PLATE DOUBLE (AP-D)
1 G2 OMNISTROBE SPEAKER
1 G2 STROBE LIGHT
1 G2 UPS (G2-UPS)
1 MS-MNT-ART-L
3 PUSH BUTTON (RED)