ATTACHMENT B6

LANDSCAPING PLANS - EAST-END
STREET SECTION: GRAND AVE EASTScale: 1/4" = 1'-0"1
VEHICLE LANE 5'-6"PLANTING AREA W/ DG6'-0"AC BIKE PATH 5'-0"DG WALKWAY

PROPERTY LINE
ROW
6" MIN

SIGNAGE PER PLAN
6" MIN
4' MAX

PLANTING AREA W/ DG
STREET SECTION: LINDA VISTA DRScale: 1/4" = 1'-0"1
4'-0" ROW
123 4
2' TYP6" MIN5'-0"DG WALKWAY3'-0"
6 6'-0"BIKE PATH1.2.3.

AC BIKE PATH(N) CONCRETE CURB AND GUTTER(N) PARALLEL PARKING SPACE

4.5.6. DG WALKWAYSIGNAGE PANEL PER PLANPLANTING AREA W/ DECOMPOSED GRANITE 5 #4 Rebar Stirrups & Horizontal Reinforcement 2'-0"
1'-9"
Embedmen SleeveHinging Lid

END VIEW - FOUNDATION
Dome
Customer Provided Lock
OPTIONSBollard Material (5" Nominal Size)PSS05000 Sch 10 Stainless SteelPSS05040 Sch 40 Stainless SteelPSS05080 Sch 80 Stainless SteelPCS05040 Sch 40 ASTM A-53 Carbon SteelPCS05080 Sch 80 ASTM A-53 Carbon Steel Bollard Cap StyleDomeStandard FlatRevealSloped
Carbon Steel Bollard FinishPowdercoal RAL #As Specified Stainless Steel Bollard FinishPolished #4 FinishAs Specified Stainless Steel Bollard MaterialType 304Type 316
Ø 5 1/2"

ELEVATION VIEW - FOUNDATION (CONCEPTUAL DESIGN ONLY)
1'-0" 3'-0"
Standard Flat Reveal Slope
#4 RebarStirrups
Plan View ofClosed Lid
Lid
Ø 10"

1 Series
BOL Bol
2 Shaft Shape
S Round Straight
T Round Tapered
RSQ Round to Square
3 Height (1)
8 8'
10 10'
12 12'
14 14'
16 16'
18 18'
20 20'
22 22'
24 24'
ORDERING GUIDE: EXAMPLE: BOL-S-12-55-55-S3-C6- T3124-STD BOL
1 2 3 4 5 6 7 8 9
4 Base Diameter(2)
55 5.5" – 20' Maximum Height
70 7.0" – 24' Maximum Height
5 Top Diameter
40 4.0"
55 5.5”
70 7.0”
6 Wood Finish
S* See color options on
finishes technical sheet
7 Metal Finish
C* See color options on
finishes technical sheet
CSM Custom Color
8 Fixture Mounting
Tenon
T2384 2 3/8" x 4" Tenon
T2784 2 7/8" x 4" Tenon
T3124 3 1/2" x 4" Tenon
T4004 4" x 4" Tenon
TXXX Specify diameter
and height
Drill
D1 1 @ 90deg
D2 2 @ 180deg
D3 2 @ 90deg
D4 3 @ 90deg
D5 4 @ 90deg

9 Special
STD Standard
MOD Modified

Bolt Circle

8.5" Dia.
11" Dia.

Conduit Opening
5" Dia.

6.5" Dia.

Pole Size

5.5"

7.0"
Base Height
(1)
32"/48"
32"/48"
Baseplate Dia.

10.5" Dia.

13.5" Dia.

Wire Void
2" Sq.
2" Sq.

Conduit
Opening
Bolt
Circle
Overall
Diameter
Wire
Void

1. Poles with a height 18' and over have a 48" tall base. Contact Structura for other base height options.

2. See wind loading tables for allowable EPA.
24'
20'
16'
12'
7"5.5"
8'
11 Product specification sheets subject to change. ©2021 STRUCTURA, INC.

Project Name:

FORM AND FUNCTION
• Sleek, low profile housing
• Spec grade performance
• Engineered for optimum thermal management
• Low depreciation rate
• Reduces energy consumption and costs up to 65%
• Exceeds IES foot candle levels utilizing the least number of poles and fixtures per project
• Optical system designed for:
- Parking Lots
- Auto Dealerships
- General Area Lighting
Type:

AREA LIGHTING
NV-1

CONSTRUCTION
• Die Cast Aluminum
• External cooling fins
• Corrosion resistant external hardware
• One-piece silicone gasket ensures IP-65 seal for electronics compartment
• One-piece Optics Plate™ mounting silicone Micro Optics • Two-piece silicone Micro Optic system ensures IP-67 level seal around each PCB
• Grade 2 Clear Anodized Optics Plate™ standard

WARRANTY
Five-year limited warranty for drivers and LEDs.

NV-1 with DPS3

LISTINGS
• Certified to UL 1598
• UL 8750
• CSA C22.2 No. 250.0
• DesignLights Consortium® (DLC)
• DesignLights Consortium Premium® (DLCP)
• IP65/ IP67 Rated
• 3G Vibration Rated per ANSI C136.31-2010
FINISH
• 3-5 mils electrostatic powder coat.
• NLS’ standard high-quality finishes prevent corrosion protects against and extreme environmental conditions
Cat# Light Dist. # of LEDs Milliamps Kelvin Volts Mounting Color Options 2700K, 80 CRI
(27K8)
3000K, 70 CRI
(30K7)
3000K, 80 CRI
(30K8)
3500K, 80 CRI
(35K8)
4000K, 70 CRI
(40K7)
4000K, 80 CRI
(40K8)
5000K, 70 CRI
(50K7)
5000K, 80 CRI
(50K8)
120-277
(UNV)
347-480
(HV)
Bronze Textured
(BRZ)
White Textured
(WHT)
Smooth White
Gloss
(SWT)
Silver
(SVR)
Black Textured
(BLK)
Smooth Black
Gloss
(SBK)
Graphite Textured
(GPH)
Grey Textured
(GRY)
Custom
(CS)
Notes:
1 3
5 2
2 1
1 1
1 2
3 4
5 Consult Factory for Lead Time. Consult Factory for 90 CRI Requests.

For Round Pole Specify RPA4 or RPA5
Standard finish is stainless steel. Can be painted to
match fixture
Universal Voltage 120-277
HSS not applicable with Nema 2 and Nema 3 Optics
Direct Pole 3” Arm
Single, D180
(DPS3)
Direct Pole 7” Arm
D180, D90, T90, T120, Quad
(DPS7)
Knuckle Mount
(KM)
Wall Mount
(WM)
Trunnion Mount
(TM)
Tennis Arm
(TA)
Mast Arm
(MA)
16 (16L)
32 (32L)
48 (48L)
64 (64L)
Type 2
(T2)
Type 3
(T3)
Type 4
(T4)
Type 5
(T5)
Nema 2
24° Narrow Beam
(N2)
Nema 3
30° Narrow Beam
(N3)
NV-1
(NV-1)
350
(35)
530
(53)
700
(7)
1050
(1)
Bird Spikes ( BS)
Marin e Grad e Finish (MGF)
Optic Plate Painted to Match F ixtur e (OPP)
Nema 7-Pin Recepta cle (PE7)
Photo cell + Recepta cle (PCR)
Recepta cle + Shor ting Cap (PER)
FSP-211 with Motion Sensor
(FSP- 20) 9'-20'' Heights
(FSP- 40) 21'-4 0' H eights
Quick Mount Brack et (QMB)
Retro fit Mount Brack et (RQMB)
Round Po le Adapto r 3"- 4" Po le (RPA4)
Round Po le Adapto r 5"- 6" Po le (RPA5)
Rotated Optic Left (ROL)
Rotated Optic Righ t (ROR)
Automo tive House Sid e Shield (AHS)
House Sid e Shield (HSS)
4 4

LED WATTAGE CHART
16L 32L 48L 64L
350 milliamps 18w - - -
530 milliamps 28w - - -
700 milliamps 36w 71w 104w 136w
1050 milliamps 56w 106w 156w 205w

SITE LIGHTING

VSR-S-YM

LISTINGS
• Certified to UL 1598
• CSA C22.2 No. 250.0
• DesignLights Consortium® (DLC)
• DesignLights Consortium Premium® (DLCP)
• IP65/ IP67 Rated

FORM AND FUNCTION
• Sleek, low profile housing
• Engineered for optimum thermal management
• Low depreciation rate
• Optical system designed for:
- Parking Lots
- Commercial Applications

CONSTRUCTION
• Spun Aluminum
• Corrosion resistant external hardware
• One-piece silicone gasket ensures IP-65 seal for
electronics compartment
• Two-piece silicone Micro Optic system ensures IP-67
level seal around each PCB

WARRANTY
Five-year limited warranty for drivers and LEDs.

FINISH
• 5 mils electrostatic powder coat.
• NLS’ standard high-quality finishes prevent corrosion protects against extreme environmental conditions

LED WATTAGE CHART
16L 32L
350 milliamps 16w -
530 milliamps 28w 56w
700 milliamps 36w 71w
1050 milliamps 56w 106w
Project Name: Type:

Color
Bronze
(BRZ)
White
(WHT)
Silver
(SVR)
Hunter
Green
(HGN)
Black
(BLK)
Graphite
(GPH)
Grey
(GRY)
Custom
(CS)
Value Series Round
S
(VSR-S)
Cat # Micro Optics
Type 2
(T2)
Type 3
(T3)
Type 4
(T4)
Type 5
(T5)
Nema 3
30° Narrow
Beam
(N3)
No. of LEDs
16 (16L)
32 (32L)
Kelvin
3000K
(30K)
4000K
(40K)
5000K
(50K)
Milliamps
350
(35)
530
(53)
700
(7)
1050
(1)
Volts
120-277
(UNV)
340-480
(HV)
Mounting
Yoke Mount (2-Bar)
Over 2⅜" Tenon (YM2)
Over 3” Tenon (YM3)
Options
Bird Spikes (BS)
Marine Grade Finish (MGF)
Surge Protector (10K)
Nema 7-Pin Receptacle (PE7)
Photocell (PC)
*Universal Voltage 120-277
Motion Sensor (MS)
FSP-211 with Motion Sensor
(UNV Voltage)
For 8' + Below (FSP-8)
For 9' to 20' (FSP-20)
For 21' to 40' (FSP-40)
* Motion Sensor and FSP-211 are integral to
the fixture
Quick Mount Bracket (QMB)
Retrofit Quick Mount Bracket (RQMB)
Rotate Optic Right (ROR)
Rotate Optic Left (ROL)
House Side Shields (HSS)
*HSS not applicable with N3 - NEMA 30° Optics
Automotive House Side Shields (AHS)
Acrylic Optics (AO)
Application
LED recessed ceiling luminaire with wide beam light distribution designed for downlighting atriums, canopies, passages and other interior and exterior locations.

Materials
Luminaire housing and faceplate constructed of die-cast marine grade, copper free (≤ 0.3% copper content) A360.0 aluminum alloy Clear safety glass
Silicone optical collimating lens
Reflector surface made of pure anodized aluminum
High temperature silicone gasket
Stainless steel screw clamps
Galvanized steep rough in ceiling pan with through wiring box NRTL listed to North American Standards, suitable for wet locations Protection class IP65
Weight: 3.1 lbs
Electrical
Operating voltage 120-277V AC
Minimum start temperature -20° C
LED module wattage 24.5 W
System wattage 28.5
W
Controlability 0-10V dimming down to 0.1%
Color rendering index Ra > 80
Luminaire lumens 2,948 lumens (3000K)
Lifetime at Ta=15°C 230,000 h (L70)
Lifetime at Ta=25°C 190,000 h (L70)
LED color temperature
4000K - Product number + K4
3500K - Product number + K35
3000K - Product number + K3
2700K - Product number + K27
BEGA can supply you with suitable LED replacement modules for up to 20 years after the purchase of LED luminaires - see website for details Finish
All BEGA standard finishes are matte, textured polyester powder coat with minimum 3 mil thickness.

Available colors Black (BLK) White (WHT) RAL:

Bronze (BRZ) Silver (SLV) CUS:

LED recessed ceiling downlights - wide beam
β = Beam angle
BEGA 1000 BEGA Way, Carpinteria, CA 93013 (805) 684-0533 [email protected] Due to the dynamic nature of lighting products and the associated technologies, luminaire data on this sheet is subject to change at the discretion of BEGA North America. For the most current technical data, please refer to bega-us .com © copyright BEGA 2018 Updated 01/25/18
Type:

BEGA Product:

Project:

Modified:

LED recessed ceiling downlights · wide beam
LED β A B C
24 827 24.5 W 29 ° 6 7⁄8 5 18
A
B
C

Description
Surface-mounted wall luminaire. IP66. Class I. IK07. Marine-grade, die-cast aluminum alloy. 5CE superior corrosion protection including PCS hardware.

Silicone CCG® Controlled Compression Gasket. Safety glass lens. Two cable entries. CAD-optimized optics for superior illumination and glare control.

Integral driver. OLC® One LED Concept. Factory-installed LED circuit board. 0- 10V Dimming comes standard with luminaire. Suitable for Up, Down, or Up/Down light distribution. Supplied with wall plate to fit over 4” recessed junction box. Specify product with 7 Digit product code – Finish Color.

Accessories, such as mounting, optical, and electrical, must be specified separately. Example: XXX-XXXX-9004 (Black) + XXX-XXXX (Accessory 1) SLS410 LED
Surface Mounted Wall Luminaires
1/6

WE-EF LIGHTING USA LLC
410-D Keystone Drive | Warrendale PA 15086 | U.S.A. | Tel +1 724 742 0030 | Fax +1 724 742 0035 | [email protected] | www.we-ef.com | 07-12-2021 05:44 Technical modifications and errors excepted
Spec Sheet | AJ100
1 Motive Path Light
Revised February 21, 2022 | Landscape Forms Inc. | 800.521.2546 | F 269.381.3455 | 7800 E. Michigan Ave., Kalamazoo, MI 49048 TV
Distributions
TIV
Motive is a sophisticated family of lights that blurs the line between indoor and outdoor lighting to create out-of-the-ordinary settings.

Designed by Justin Champaign, Motive celebrates the beauty of illumination and its interaction with architecture, objects, and space. The luminaires’ neutral sculptural form address an array of applications for buildings and grounds, pathways, social spaces, and high-profile areas such as art installations and entrances.

Warranty
LED lighting products are warranted for six years.
35 1/2"
905 mm
32 1/2"
825 mm
Ø 10 1/2"
265 mm
Housing & Materials
A UV stable, impact modified diffused acrylic lens seals to the cast aluminum round luminaire housing. Luminaire mounts via a cast aluminum hub bolted directly to the top of cast aluminum pole. The luminaire’s cast lid is secured with three socket head set screws. All hardware is magni-coated.

Electrical
Internally mounted surge protected 120V through 277V 50/60Hz electronic driver. -40°C start temperature., leading edge and trailing edge phase-cut dimmable. Motive path light ships prewired.

Light Engine
Cast aluminum light cartridge features high powered LEDs mounted to a RoHS compliant circuit board delivering indirect lighting in conjunction with semi-specular aluminum reflector. Motive Path Light can be configured with a Type IV or Type V distribution. The replaceable cartridge provides ease of installation and serviceability.

Available in 2700K, 3000K, 3500K, and 4000K. >80 CRI across all available color temperatures.

Weight: 16 lbs
TM21 L70(10k): 60,000 hrs
Protection Class: IP66
Certification
UL Listed for Wet Location, CE, International Dark Sky Approved, Buy America Compliant, RoHS Compliant
Designed by Justin Champaign
Click here for patent in formation related to this product.

Application
Recessed wall luminaire with asymmetric forward throw light distribution.

The specially designed optics in this luminaire allow for superior illumination of ground surfaces at an extremely low mounting height. Separate installation housing allows for seamless coordination into construction and easy maintenance.

Materials
Luminaire housing constructed of die-cast aluminum marine grade, copper free (≤ 0.3% copper content) A360.0 aluminum alloy Clear safety glass with optical texture
Reflector made of pure anodized aluminum
Silicone applied robotically to casting, plasma treated for increased adhesion
High temperature silicone gasket
Mechanically captive stainless steel fasteners
Stainless steel helicoils
Stainless steel screw clamps
Composite installation housing
NRTL listed to North American Standards, suitable for wet locations Protection class IP65
Weight: 1.7 lbs
Electrical
Operating voltage 120-277V AC
Minimum start temperature -30° C
LED module wattage 7.2 W
System wattage 8.8 W
Controlability 0-10V, TRIAC, and ELV dimmable
Color rendering index Ra > 80
Luminaire lumens 493 lumens (4000K)
LED service life (L70) 60,000 hours
LED color temperature
2700K - Product number + K27
3000K - Product number + K3 ( EXPRESS)
3500K - Product number + K35
4000K - Product number + K4 ( EXPRESS)
BEGA can supply you with suitable LED replacement modules for up to 20 years after the purchase of LED luminaires - see website for details Finish
All BEGA standard finishes are matte, textured polyester powder coat with minimum 3 mil thickness.

Available colors Black (BLK) White (WHT) RAL:

Bronze (BRZ) Silver (SLV) CUS:

Recessed wall luminaire - Extended throw
BEGA 1000 BEGA Way, Carpinteria, CA 93013 (805) 684-0533 [email protected] Due to the dynamic nature of lighting products and the associated technologies, luminaire data on this sheet is subject to change at the discretion of BEGA North America. For the most current technical data, please refer to bega-us .com © copyright BEGA 2019 Updated 09/27/19
Type:

BEGA Product:

Project:

Modified:

Available options
FSC Fusing
FFRO Factory fixed reduced output
See individual accessory spec sheet for details.

LED recessed wall luminaires · asym. forward throw

LED A B C
24 064 7.2 W 10 1⁄8 2 3⁄4 5
B
CA
B
C
Fully enclosed luminaire with
installation housing ensures
seamless integration and
weathertight operation.

STANDARD IRRIGATION & LANDSCAPE PLAN NOTES FOR

PRIVATELY CONSTRUCTED COMMUNITY FACILITIES DISTRICTS

NOTE TO DESIGNERS: The following standard notes shall be included on the respective irrigation and landscape plan sheets for all privately constructed Community Facilities Districts (CFD). Project -specific notes for items not covered by the City’s standard drawings Approved Materials List, and these standard notes are subject to Public Works Department approval.

Additionally, the following notes shall not be amended without written approval from the Public Works Department.

STANDARD IRRIGATION NOTES

1. The developer shall schedule a pre -construction meeting with the Public Works Department landscape inspector via the Development Services Department inspector prior to the commencement of irrigation work. The d eveloper, its landscape architect, and its landscape contractor shall attend the meeting. The meeting shall be at a time and place acceptable to the Public Works landscape inspector. The developer shall provide the landscape inspector with the contact information for its landscape architect, project manager, superintendent , and irrigation and landscape contractor at the meeting.

2. The developer shall submit a complete materials list and associated catalog cuts for all manufactured materials to be incorporated in the work to the Public Works Department prior to the start of construction.

3. The work shall be cons tructed in accordance with the developer ’s City-approved plans, the City’s irrigation and landscape standard drawings, the City’s Approved Materials List, the Standard Specifications for Public Works Construction, and these standard irrigation notes.

4. Review and approval of the d eveloper’s plans by the City does not warrant that the plans are accurate and complete. The responsibility for accuracy and co mpleteness of drawings lies solely with the developer.

5. Irrigation plans are diagrammatic. The actual location of irrigation improvements shall be in planted areas where possible. Locations of irrigation improvements are subject to the approval of the Public Works Department prior to installation. Irrigation controllers shall be installed “outside” of irrigation coverage.

6. All threaded fitting require Teflon tape.

7. Above ground irrigation systems are not permitted.

8. Control wiring shall be color-coded and labeled at the controller and all junction and valve boxes shall correspond to the appropriate station. Install three additional control sires from the controller to the end of each mainline run.

Rev. 5/15/18 Page 2

9. Dedicated water and electrical services shall be provided for all irrigation systems and controllers. Contractor shall verify and coordinate locations of irrigation water services and irrigation controller electrical service locations with other trades to ensure they correspond with irrigation water points of conne ction and controller locations.

Electrical and water feeds from private sources are not allowed.

10. Controller and communication wire splices shall only be made with Public Works Department approval and, when approved, shall only be made in an approved box w ith a minimum of three foot loop (six feet of wire).

11. Irrigation controllers shall be installed within the limits of the CF D at locations approved by the landscape inspector.

12. The developer shall submit the installation certification of the controller assembly fabricator to the Public Works Department prior to the coverage test inspection.

13. As-built drawings shall be kept on-site and up to date at all times.

14. As-built drawings shall show the locations of:
a. Water services and meter.
b. Electrical services and meter.
c. Backflow assemblies.
d. Controller assemblies.
e. Automatic control valves.
f. Remote control valves with station designation.
g. Isolation and quick coupler valves.
h. Pressure main lines.
i. Control and communication wires.
j. Lateral lines.
k. Sleeves.

15. Developer shall p rovide one set of full size (24 inches by 36 inches) redlined as -built drawings at the time of mainline pressure test inspection to facilitate the inspection.

16. Developer shall submit one set of redlined as -builts prepared by the landscape architect at the time of the coverage test inspection. Once the as-builts are approved by the landscape i nspector the l andscape architect shall prepare mylars. One set of mylars , and two sets of 24 inch by 36 inch, blue line as -builts shall be submitted to the Public Works Department prior to the commencement of the maintenance period.

17. Developer shall submit 11 inch by 17 inch, hermetically sealed , color irrigation station diagrams prior to coverage test inspection. Diagrams shall show the irrigation limits of each station indicated with separate, unique colors.

18. The Developer shall schedule inspections 48 hours in advance of the work being ready for inspection. Inspections shall be scheduled by calling (760) 752-7550 ext. 3550. If the work is not ready for inspection on the scheduled date and time , the developer shall reschedule the inspection as above. The City may charge the developer for resche duled inspections and withhold further inspections until such time as the developer pays the re-inspection fee.

19. Irrigation inspections are required for the following:
a. Pressure main layout including water service, electrical service, controller, and backflow preventer locations.

Rev. 5/15/18 Page 3

b. Excavation and bedding including control and communication wiring. c. Mainline pressure test (as-builts required).
d. Lateral lines and terminal appurtenances.
e. Preliminary coverage test prior to planting (see required submittals above).

20. The irrigation system shall hold 150psi for a mi nimum of four hours for the mainline pressure test.

21. Pressure mainlines shall be “center loaded” and not backfilled until such time as the pressures test has been completed and accepted.

22. Projects that are inac tive for one year or longer are subject to implementation of all irrigation standards changes that have been adopted by the City of San Marcos during the period of inactivity.

23. Excavation for new irrigation systems in existing landscaped areas shall be perf ormed by hand unless otherwise approved by the Public Works Department, and shall be outside of existing tree drip lines.

STANDARD PLANTING NOTES

1. The work shall be constructed and mai ntained in accordance with the developer’s City - approved plans, irrigation and landscape standard drawings, A pproved Materials List, as well as these standard planting notes.

2. Soil samples for amendment testing shall be taken after completion of grading and prior to weed control and soil preparation at a minimum of three locations approved by the Public Works Department. Tests shall be performed by an approved laboratory. Tests performed shall include , but are not limited to : organic matter content, N/P/K., Ph, electrical conductivity, and percent silt, sand, and clay. Test results and application recommendations shall be submitted to the Public Works Department prior to application of amendments. Amendments shall be applied pursuant to the laboratory and manufacturers recommendations.

3. Control weeds by watering for three wee ks to adequately germinate the seedbed and then apply a post -emergent herbicide by a licensed applicator and wait as directed by the manufacturer before planting.

4. Percolation tests shall be performed on all tree planting pits. Pits shall be filled with 18 inches of water and allowed to drain completely. Pits shall then be filled with 12 inches of water and allowed to drain. The second fill must drain at a minimum rate of one inch per hour, for a four-hour duration.

5. Tree well drain systems shall be installed pursuant to City of San Marcos Standard Drawings when percolation tests fail.

6. The developer shall provide positive drainage in all landscape areas.

7. The developer shall schedule inspections 48 hours in advance of the work being ready for inspection. In spections shall be scheduled by calling (760) 752-7550 ext. 3550. If the work is not ready for inspection on the scheduled date and time , the developer shall reschedule the inspection as a bove. The City may charge the d eveloper for rescheduled inspections and withhold further inspections until such time as the d eveloper pays the re-inspection fee.

← All documents from this meeting