Connors Park Quick Fit LED Retrofit
San Marcos,CA
Sales Representative: Karin Anderson · Designed By: D.Palmer · Design No.: 254513A · July 16, 2026 Not to be reproduced in whole or part without the written consent of Musco Lighting. ©1981, 2026 Musco Sports Lighting, LLC.

Sports Illustrated Stadium, Harrison, New Jersey, USA UBS Arena, Elmont, New York, USA Iowa Women of Achievement Bridge, Des Moines, Iowa, USA Tottenham Hotspur FC Training Ground, Tottenham, London, UK

PROJECT SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Palmer • File #254513A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Connors Park Quick Fit LED Retrofit
San Marcos,CA

LIGHTING SYSTEM
Structure/Fixture Summary
Structure ID Structure Height Fixt. Attachment Ht. Fixture Qty Fixture Type Load Circuit F1-F4 70' 70' 6 QF-900 5.49 kW A
16' 2 TLC-BT-575 1.15 kW A
T1-T4 50' 50' 1 QF-900 0.75 kW C
50' 2 QF-900 1.50 kW B
8 44 35.56 kW
Circuit Summary
Circuit Description Load Fixture Qty
A Football 26.56 kW 32
B Tennis Low 6.00 kW 8
C Tennis High 3.00 kW 4
Fixture Type Summary
Type Circuit Source Wattage Lumens L90 L80 L70 Quantity QF-900 A LED 5700K - 75 CRI 915W 117,000 -- -- -- 24
QF-900 B LED 5700K - 75 CRI 750W 89,000 -- -- -- 8
QF-900 C LED 5700K - 75 CRI 750W 89,000 -- -- -- 4
TLC-BT-575 A LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 8 Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage 208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
QF-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3
TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5
Light Level Summary
Calculation Grid Summary
Grid Name Calculation Metric Illumination Ave Circuits Fixture Qty Ave Min Max Max/Min Ave/Min Football Horizontal Illuminance 33.5 29 39 1.35 1.16 A 32 Project Spill @ 3ft. Horizontal Illuminance 0.008 0.00 0.04 - - A,B,C 44 Project Spill @ 5ft. Max Candela Metric 598.640 0.00 1848.78 - - A,B,C 44 Project Spill @ 5ft. Max Vertical Illuminance Metric 0.018 0.00 0.08 - - A,B,C 44 Project Spill @ 5ft. True Max Vert Illuminance Metric 0.017 0.00 0.08 - - A,B,C 44 Tennis Horizontal Illuminance 52.2 47 55 1.17 1.10 B,C 12 Tennis Eval Horizontal 0.0 0 0 - - B,C 12
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Palmer • File #254513A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC. 32 31
29 31
34 34
32 32
36 36
34 33
31 30
35 36
31 32
31 31
34 35
33 32
30 36
37 37
37 29
32 36
36 36
35 33
33 36
35 35
35 33
30 35
35 36
37 30
31 31
37 39
33 32
32 32
38 39
34 33
32 33
36 37
34 33
29 32
29 31
33 32
F1 F2
F4 F3
10 10
20 20
30 30
40 40
50 50
40 40
30 30
20 20
10 10
110'
105'
108'
106'
109'
107'
108'
107'
SCALE IN FEET 1 : 40
0' 40' 80'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 F1-F4 70' - 70' QF-900 6 6 0

15.5' TLC-BT-575 2 2 0
4 Totals 32 32 0
Above Field Level is height of fixtures above area shown Connors Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Football
Size: 360' x 160'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid
Guaranteed Average: 30
Scan Average: 33.5
Maximum: 39
Minimum: 29
Avg/Min: 1.16
Guaranteed Max/Min: 2.5
Max/Min: 1.35
UG (adjacent pts): 1.26
CU: 0.68
No. of Points: 72

FIXTURE INFORMATION
Fixture Type: QF-900/TLC-BT-575
Design Lumens: 114726 / 116296 / 52651
Avg Lamp Tilt Factor: 1.000
Add'l Non-Rec LLF: 1.000
Recoverable LLF: 1.000
Total LLF: 1.000
No. of Fixtures: 32
Avg KW: 26.56 (26.56 max)
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Palmer • File #254513A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

T3
T4 T1
T2
54 53 55 54 54
53 52 55 51 51
51 52 47 52 50 51 52 48 52 50
52 52 55 51 51
54 53 55 53 53
57'
56'
59'
56'
57'
55'
55'
56'
SCALE IN FEET 1 : 20
0' 20' 40'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 T1-T4 50' - 50' QF-900 3 3 0
4 Totals 12 12 0
Above Field Level is height of fixtures above area shown Connors Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Tennis
Size: 2 Court - 8' Spacing
Spacing: 20.0' x 20.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid
Guaranteed Average: 30
Scan Average: 52.2
Maximum: 55
Minimum: 47
Avg/Min: 1.10
Guaranteed Max/Min: 2
Max/Min: 1.17
UG (adjacent pts): 0.00
CU: 0.59
No. of Points: 30

FIXTURE INFORMATION
Fixture Type: QF-900
Design Lumens: 87297 / 88473
Avg Lamp Tilt Factor: 1.000
Add'l Non-Rec LLF: 1.000
Recoverable LLF: 1.000
Total LLF: 1.000
No. of Fixtures: 12
Avg KW: 9.00 (9.00 max)
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Palmer • File #254513A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

F1 F2
F4 F3
10 10
20 20
30 30
40 40
50 50
40 40
30 30
20 20
10 10
T3
T4 T1
T2
(299.08', 175.32', 0.00')

0.01 0.00

0.00 0.00

0.00 0.00

0.00 0.00 0.00 0.01 0.01 0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.01

0.01 0.01

0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.02 0.00

0.01 0.01

0.01 0.01

0.01 0.01

0.01 0.01

0.00 0.00 0.00 0.00 0.01 0.03 0.04 0.04 0.02 0.01 0.00 0.00 0.00 0.01 0.01

0.01 0.01

0.00 0.01

0.01 0.01

0.01 0.01

0.02 0.02

0.01 0.01

0.01 0.01

0.01 0.00

0.01 0.01

0.01 0.00 0.00 0.00 0.00 0.02 0.04 0.04 0.03 0.01
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 F1-F4 70' - 70' QF-900 6 6 0

15.5' TLC-BT-575 2 2 0
4 T1-T4 50' - 50' QF-900 3 3 0
8 Totals 44 44 0
Above Field Level is height of fixtures above area shown Connors Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill @ 3ft.

Spacing: 30.0'
Height: 3.0' above grade
Illumination Summary

INITIAL HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 0.008
Maximum: 0.04
Minimum: 0.00
CU: 0.00
No. of Points: 83

FIXTURE INFORMATION
Fixture Type: QF-900/TLC-BT-575
Design Lumens: 114726 / 116296 / 52651 / 87297 / 88473
Avg Lamp Tilt Factor: 1.000
Add'l Non-Rec LLF: 1.000
Recoverable LLF: 1.000
Total LLF: 1.000
No. of Fixtures: 44
Avg KW: 35.56 (35.56 max)
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Palmer • File #254513A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

F1 F2
F4 F3
10 10
20 20
30 30
40 40
50 50
40 40
30 30
20 20
10 10
T3
T4 T1
T2
(299.08', 175.32', 0.00')
423.15
134.84

30.17 90.96

78.91 176.20
158.39

52.13 260.43 437.92 431.26 138.43 50.16
149.21
173.54

77.34 65.34

4.82 20.16
392.32
465.87
433.08
528.09
209.84

0.00 1.12

45.06 107.60
112.90

59.04 1429.51 393.59
1498.20
1233.63
1526.92
1054.45
520.93
394.19
720.95
661.37
340.26 211.18 113.76 212.43 400.22 827.03 1315.02 1417.81 1484.93 1067.28 593.63 287.76 190.21 95.01 618.64
773.37
443.24
261.43
728.32
1416.80
1403.49
1386.50
1665.85
1848.78
1654.86
1087.05
981.76
1113.36
1110.63
621.57
210.85
561.77
751.54
516.24 75.30 81.12 171.28 476.77 960.83 1466.19 1624.53 1438.30 938.23 SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 F1-F4 70' - 70' QF-900 6 6 0

15.5' TLC-BT-575 2 2 0
4 T1-T4 50' - 50' QF-900 3 3 0
8 Totals 44 44 0
Above Field Level is height of fixtures above area shown Connors Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL CANDELA (PER FIXTURE)
Entire Grid
Scan Average: 598.640
Maximum: 1848.78
Minimum: 0.00
CU: 0.00
No. of Points: 83

FIXTURE INFORMATION
Fixture Type: QF-900/TLC-BT-575
Design Lumens: 114726 / 116296 / 52651 / 87297 / 88473
Avg Lamp Tilt Factor: 1.000
Add'l Non-Rec LLF: 1.000
Recoverable LLF: 1.000
Total LLF: 1.000
No. of Fixtures: 44
Avg KW: 35.56 (35.56 max)
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Palmer • File #254513A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

F1 F2
F4 F3
10 10
20 20
30 30
40 40
50 50
40 40
30 30
20 20
10 10
T3
T4 T1
T2
(299.08', 175.32', 0.00')

0.01 0.00

0.00 0.00

0.00 0.00

0.00 0.00 0.01 0.03 0.02 0.00 0.00

0.00 0.00

0.00 0.00

0.00 0.00

0.01 0.02

0.02 0.02

0.01 0.00

0.00 0.00

0.00 0.00

0.00 0.03 0.01

0.03 0.03

0.03 0.02

0.01 0.01

0.02 0.02

0.01 0.00 0.00 0.01 0.02 0.06 0.07 0.07 0.03 0.02 0.01 0.00 0.00 0.01 0.02

0.02 0.01

0.01 0.02

0.03 0.03

0.03 0.04

0.04 0.04

0.03 0.02

0.02 0.02

0.01 0.01

0.02 0.02

0.02 0.00 0.00 0.00 0.01 0.03 0.07 0.08 0.06 0.03
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 F1-F4 70' - 70' QF-900 6 6 0

15.5' TLC-BT-575 2 2 0
4 T1-T4 50' - 50' QF-900 3 3 0
8 Totals 44 44 0
Above Field Level is height of fixtures above area shown Connors Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL MAX VERTICAL FOOTCANDLES
Entire Grid
Scan Average: 0.018
Maximum: 0.08
Minimum: 0.00
CU: 0.00
No. of Points: 83

FIXTURE INFORMATION
Fixture Type: QF-900/TLC-BT-575
Design Lumens: 114726 / 116296 / 52651 / 87297 / 88473
Avg Lamp Tilt Factor: 1.000
Add'l Non-Rec LLF: 1.000
Recoverable LLF: 1.000
Total LLF: 1.000
No. of Fixtures: 44
Avg KW: 35.56 (35.56 max)
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

EQUIPMENT LAYOUT
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Palmer • File #254513A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Connors Park Quick Fit LED Retrofit
San Marcos,CA
F1 F2
F4 F3
10 10
20 20
30 30
40 40
50 50
40 40
30 30
20 20
10 10 110'
105'
108'
106'
109'
107'
108'
107'
Tennis
2 Court - 8' Spacing
T3
T4 T1
T2
57'
56'
59'
56'
57'
55'
55'
56'
(299.08', 175.32', 0.00')
(0.00', 0.00', 0.00')
SCALE IN FEET 1 : 100
0' 100' 200'
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Equipment Layout
INCLUDES:
· Football
· Tennis
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE
ID
SIZE
GLOBAL

ELEVATION

ABOVE GLOBAL LEVEL FIXTURE TYPE QTY/POLE
4 F1-F4 70' -
70'

15.5'
QF-900
TLC-BT-575
6 2
4 T1-T4 50' - 50' QF-900 3
8 Totals 44
Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage
208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
QF-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3
TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5
Above Global Level is height of fixtures above design (0,0,0) Hollandia Park Quick Fit LED Retrofit
San Marcos,CA
Sales Representative: Karin Anderson · Designed By: D.Lohman · Design No.: 254517A · July 17, 2026 Not to be reproduced in whole or part without the written consent of Musco Lighting. ©1981, 2026 Musco Sports Lighting, LLC.

Sports Illustrated Stadium, Harrison, New Jersey, USA UBS Arena, Elmont, New York, USA Iowa Women of Achievement Bridge, Des Moines, Iowa, USA Tottenham Hotspur FC Training Ground, Tottenham, London, UK

PROJECT SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254517A • 17-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Hollandia Park Quick Fit LED Retrofit
San Marcos,CA

LIGHTING SYSTEM
Structure/Fixture Summary
Structure ID Structure Height Fixt. Attachment Ht. Fixture Qty Fixture Type Design Load Circuit A1-A2 70' 70' 2 QF-900 1.83 kW C
70' 3 QF-900 2.75 kW A
16' 1 TLC-BT-575 0.57 kW A
A3 70' 70' 5 QF-900 4.58 kW B
16' 1 TLC-BT-575 0.57 kW B
A4 70' 70' 5 QF-900 4.57 kW B
16' 1 TLC-BT-575 0.57 kW B
B1-B2 70' 70' 1 QF-900 0.92 kW C
70' 6 QF-900 5.49 kW A
16' 1 TLC-BT-575 0.57 kW A
B3-B4 70' 70' 6 QF-900 5.49 kW B
16' 1 TLC-BT-575 0.57 kW B
C1-C2 70' 70' 5 QF-900 4.58 kW A
16' 2 TLC-BT-575 1.15 kW A
C3-C4 70' 70' 5 QF-900 4.58 kW B
16' 2 TLC-BT-575 1.15 kW B
S1 70' 70' 5 QF-900 4.58 kW D
S2 70' 70' 4 QF-900 3.66 kW D
S3-S4 70' 70' 5 QF-900 4.58 kW D
S5 70' 70' 4 QF-900 3.66 kW D
S6 70' 70' 5 QF-900 4.58 kW D
SK1-SK2 50' 50' 2 QF-900 1.83 kW E
20 114 98.87 kW
*Fixtures in this design have dimmed output values to meet design specific needs.

Circuit Summary
Circuit Description Design Load Fixture Qty
A West BB/SO 30.22 kW 36
B East BB 33.88 kW 40
C West BB 5.49 kW 6
D East SO 25.62 kW 28
E Skate Park 3.66 kW 4
Fixture Type Summary
Type Circuit Source Avg. Wattage Avg. Lumens L90 L80 L70 Quantity QF-900 A LED 5700K - 75 CRI 915W 117,000 -- -- -- 28
QF-900 B LED 5700K - 75 CRI 914W 116,928 -- -- -- 32
QF-900 C LED 5700K - 75 CRI 915W 117,000 -- -- -- 6
QF-900 D LED 5700K - 75 CRI 915W 117,000 -- -- -- 28
QF-900 E LED 5700K - 75 CRI 915W 117,000 -- -- -- 4
TLC-BT-575 A LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 8 TLC-BT-575 B LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 8 Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage 208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
QF-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3
TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5
*Amp draw based on 100% fixture output, consult design specific datasheet for adjusted amperage draw chart Light Level Summary
Calculation Grid Summary
Grid Name Calculation Metric Illumination Ave Circuits Fixture Qty Ave Min Max Max/Min Ave/Min Baseball East (Infield) Horizontal Illuminance 51.48 37 65 1.76 1.40 B 40 Baseball East (Outfield) Horizontal Illuminance 31.86 19 44 2.34 1.69 B 40 Baseball West (Infield) Horizontal Illuminance 53.27 37 65 1.77 1.45 A,C 42 Baseball West (Outfield) Horizontal Illuminance 31.40 19 44 2.25 1.62 A,C 42 Project Spill 150' Offset @ 3ft. Horizontal Illuminance 0.0285 0.00 0.15 526.131 101.731 A,B,C,D,E 114 Project Spill 150' Offset @ 5ft. Max Candela Metric 3176.0679 40.47 9931.24 245.371 78.471 A,B,C,D,E 114 Project Spill 150' Offset @ 5ft. Max Vertical Illuminance Metric 0.0764 0.00 0.35 694.785 151.212 A,B,C,D,E 114 Skate Park Horizontal Illuminance 34.48 22 46 2.12 1.59 E 4 Soccer East Horizontal Illuminance 30.62 22 36 1.59 1.36 D 28 Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254517A • 17-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

C1
A1
A2
C2
B2
B1
52 60
49 50
48 35
25 29
27 20
61 65
59 62
63 44
30 31
30 29
21 47
57 64
62 53
40 33
35 34
33 24
43 54
57 52
43 34
34 36
37 37
30 51
53 47
42 37
31 31
35 38
34 41
43 39
35 32
30 30
32 32
26 28
35 38
36 31
32 32
29 24
29 32
38 38
32 32
33 24
25 29
36 37
31 28
25 19
29 33
35 29
24 20
24 26
42'
185'
57'
49'
47'
56'
309'
166'
159'
285'
186'
42'
SCALE IN FEET 1 : 60
0' 60' 120'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A1-A2 70' - 70' QF-900 5 5 0

15.5' TLC-BT-575 1 1 0
2 B1-B2 70' - 70' QF-900 7 7 0

15.5' TLC-BT-575 1 1 0
2 C1-C2 70' - 70' QF-900 5 5 0

15.5' TLC-BT-575 2 2 0
6 Totals 42 42 0
Above Field Level is height of fixtures above area shown Hollandia Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Baseball West
Size: 300'/300'/300' - basepath 90'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 53.27 31.40
Maximum: 65 44
Minimum: 37 19
Avg/Min: 1.45 1.62
Max/Min: 1.77 2.25
UG (adjacent pts): 1.31 1.48
CU: 0.74
No. of Points: 25 71

FIXTURE INFORMATION
Applied Circuits: A,C
No. of Fixtures: 42
Total Load: 35.71 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254517A • 17-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

B3
B4
A3
A4
C3
C4
46 61
50 49
51 35
28 29
28 23
61 65
58 53
56 44
36 37
31 35
23 46
55 61
54 51
42 38
40 37
29 19
43 51
54 47
41 38
38 40
36 23
53 53
50 42
37 34
33 33
32 25
36 44
42 37
34 31
30 28
26 20
24 35
37 37
34 30
26 26
22 34
40 42
35 28
26 21
32 41
42 34
25 20
32 36
31 29
22 23
53'
27 58'
59'
55'
183'
42'
104'
287'
285'
97'
42'
183'
SCALE IN FEET 1 : 60
0' 60' 120'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A3-A4 70' - 70' QF-900 5 5 0

15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' QF-900 6 6 0

15.5' TLC-BT-575 1 1 0
2 C3-C4 70' - 70' QF-900 5 5 0

15.5' TLC-BT-575 2 2 0
6 Totals 40 40 0
Above Field Level is height of fixtures above area shown Hollandia Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Baseball East
Size: 300'/300'/300' - basepath 90'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 51.48 31.86
Maximum: 65 44
Minimum: 37 19
Avg/Min: 1.40 1.69
Max/Min: 1.76 2.34
UG (adjacent pts): 1.33 1.56
CU: 0.74
No. of Points: 25 66

FIXTURE INFORMATION
Applied Circuits: B
No. of Fixtures: 40
Total Load: 33.88 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254517A • 17-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC. 32 28
25 23
22 25
31 32
30 29
30 28
28 30
30 31
33 33
33 31
30 32
31 29
28 36
36 32
33 35
34 26
26 33
33 33
34 36
34 26
25 31
33 32
33 35
33 27
26 32
34 32
32 34
32 26
27 34
34 33
33 35
33 26
27 34
34 31
31 34
33 26
28 29
28 28
29 32
32 30
32 32
30 29
29 31
30 33
31 33
27 24
25 27
31 36
S5
S2
S3
S6
S1
S4
130'
1'
130'
121'
130'
1'
130'
121'
130'
121'
130'
121'
SCALE IN FEET 1 : 60
0' 60' 120'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 S1
S3-S4
S6
70' - 70' QF-900 5 5 0
2 S2
S5 70' - 70' QF-900 4 4 0
6 Totals 28 28 0
Above Field Level is height of fixtures above area shown Hollandia Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Soccer East
Size: 360' x 240'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 30.62
Maximum: 36
Minimum: 22
Avg/Min: 1.36
Max/Min: 1.59
UG (adjacent pts): 1.34
CU: 0.83
No. of Points: 96

FIXTURE INFORMATION
Applied Circuits: D
No. of Fixtures: 28
Total Load: 25.62 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254517A • 17-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

SK1
SK2
30 37
38 33
23 25
34 40
41 36
29 29
35 40
43 39
33 31
37 42
45 43
37 33
39 43
46 43
36 29
36 41
43 41
35 25
30 36
38 38
35 22
27 31
34 36
36 29
22 27
31 33
34 36
32 23
31 34
34 35
36 35
31 36
34 33
33 31
2'
82'
44'
40'
SCALE IN FEET 1 : 30
0' 30' 60'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 SK1-SK2 50' - 50' QF-900 2 2 0
2 Totals 4 4 0
Above Field Level is height of fixtures above area shown Hollandia Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Skate Park
Size: 150' x 70'
Spacing: 10.0' x 10.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 34.48
Maximum: 46
Minimum: 22
Avg/Min: 1.59
Max/Min: 2.12
UG (adjacent pts): 1.43
CU: 0.51
No. of Points: 68

FIXTURE INFORMATION
Applied Circuits: E
No. of Fixtures: 4
Total Load: 3.66 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254517A • 17-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

C1
A1
A2
C2
B2
B1
(18.19', -6.24', 0.00')
B3
B4
A3
A4
C3
C4
(472.49', -179.46', 0.00')
S5
S2
S3
S6
S1
S4
(1085.00', -5.23', 0.00')
SK1
SK2
(268.90', -349.86', 0.00')

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.1 0.1 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.1

0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.1 0.1 0.1 0.1

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0
SCALE IN FEET 1 : 200
0' 200' 400'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 A1-A4 70' - 70' QF-900 5 5 0

15.5' TLC-BT-575 1 1 0
2 B1-B2 70' - 70' QF-900 7 7 0

15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' QF-900 6 6 0

15.5' TLC-BT-575 1 1 0
4 C1-C4 70' - 70' QF-900 5 5 0

15.5' TLC-BT-575 2 2 0
4 S1
S3-S4
S6
70' - 70' QF-900 5 5 0
2 S2
S5 70' - 70' QF-900 4 4 0
2 SK1-SK2 50' - 50' QF-900 2 2 0
20 Totals 114 114 0
Above Field Level is height of fixtures above area shown Hollandia Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill 150' Offset @ 3ft.

Spacing: 30.0'
Height: 3.0' above grade
Illumination Summary

INITIAL HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 0.0285
Maximum: 0.15
Minimum: 0.00
CU: 0.00
No. of Points: 162

FIXTURE INFORMATION
Applied Circuits: A,B,C,D,E
No. of Fixtures: 114
Total Load: 98.87 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254517A • 17-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

C1
A1
A2
C2
B2
B1
(18.19', -6.24', 0.00')
B3
B4
A3
A4
C3
C4
(472.49', -179.46', 0.00')
S5
S2
S3
S6
S1
S4
(1085.00', -5.23', 0.00')
SK1
SK2
(268.90', -349.86', 0.00')
4558
1320
912
331
266 216 317 413 425 353 346 519 547 460 333 429 445 631 704 440
223
226
587
1519
2361
3800
4848
4927
4218
3295
2464
2670
1974
701
136
246
523
603
376
341 339 250 193 299 312 240 509 599 532 400 613 704 738 622 784
815
483
694 5100 4250 1550 1408 1466 1065 6625 3944 4871 5554
2850
789
887
2146
2487
2519
2655
2080
1611
1693
2530
2500
299 1251 61
62 40
142
231
552
236
167
100
63 56
71 71
608
1725
2547
3203
2829
6332
2517 5179 8671 9763 9560 7180 9931 8686 2590
1664
1661
1819
2037
2797
4213
6031
6529
8065
4972
3797
5570
7639
7678
8251
8813
8448
7704
6712
7294
8123
7347
7547
8181 7954 7426 7198 6534
7053
7060
7002
4167
6443
8560
8482
7643
6272
7756
6925 2678
1272 2236 4567 6464 5299
4205
4373
3432
4698
6506
7428
7571
SCALE IN FEET 1 : 200
0' 200' 400'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 A1-A4 70' - 70' QF-900 5 5 0

15.5' TLC-BT-575 1 1 0
2 B1-B2 70' - 70' QF-900 7 7 0

15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' QF-900 6 6 0

15.5' TLC-BT-575 1 1 0
4 C1-C4 70' - 70' QF-900 5 5 0

15.5' TLC-BT-575 2 2 0
4 S1
S3-S4
S6
70' - 70' QF-900 5 5 0
2 S2
S5 70' - 70' QF-900 4 4 0
2 SK1-SK2 50' - 50' QF-900 2 2 0
20 Totals 114 114 0
Above Field Level is height of fixtures above area shown Hollandia Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill 150' Offset @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL CANDELA (PER FIXTURE)
Entire Grid
Scan Average: 3176.0679
Maximum: 9931.24
Minimum: 40.47
CU: 0.00
No. of Points: 162

FIXTURE INFORMATION
Applied Circuits: A,B,C,D,E
No. of Fixtures: 114
Total Load: 98.87 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254517A • 17-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

C1
A1
A2
C2
B2
B1
(18.19', -6.24', 0.00')
B3
B4
A3
A4
C3
C4
(472.49', -179.46', 0.00')
S5
S2
S3
S6
S1
S4
(1085.00', -5.23', 0.00')
SK1
SK2
(268.90', -349.86', 0.00')

0.1 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.2 0.2 0.2

0.1 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.1 0.1

0.1 0.0

0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.2

0.1 0.2 0.3 0.2 0.2 0.2 0.2 0.2 0.1

0.1 0.1

0.1 0.1

0.2 0.2

0.2 0.3

0.4 0.2

0.2 0.2

0.1 0.2

0.2 0.2

0.2 0.1

0.1 0.1

0.1 0.1

0.1 0.1 0.2 0.2 0.2 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.0 0.1 0.1 0.1 0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.2
SCALE IN FEET 1 : 200
0' 200' 400'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 A1-A4 70' - 70' QF-900 5 5 0

15.5' TLC-BT-575 1 1 0
2 B1-B2 70' - 70' QF-900 7 7 0

15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' QF-900 6 6 0

15.5' TLC-BT-575 1 1 0
4 C1-C4 70' - 70' QF-900 5 5 0

15.5' TLC-BT-575 2 2 0
4 S1
S3-S4
S6
70' - 70' QF-900 5 5 0
2 S2
S5 70' - 70' QF-900 4 4 0
2 SK1-SK2 50' - 50' QF-900 2 2 0
20 Totals 114 114 0
Above Field Level is height of fixtures above area shown Hollandia Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill 150' Offset @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL MAX VERTICAL FOOTCANDLES
Entire Grid
Scan Average: 0.0764
Maximum: 0.35
Minimum: 0.00
CU: 0.00
No. of Points: 162

FIXTURE INFORMATION
Applied Circuits: A,B,C,D,E
No. of Fixtures: 114
Total Load: 98.87 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

EQUIPMENT LAYOUT
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254517A • 17-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Hollandia Park Quick Fit LED Retrofit
San Marcos,CA
C1
A1
A2
C2
B2
B1
(18.19', -6.24', 0.00')
B3
B4
A3
A4
C3
C4
(472.49', -179.46', 0.00')
S5
S2
S3
S6
S1
S4
(1085.00', -5.23', 0.00')
SK1
SK2
(268.90', -349.86', 0.00')
(0.00', 0.00', 0.00')
SCALE IN FEET 1 : 120
0' 120' 240'
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Equipment Layout
INCLUDES:
· Baseball East
· Baseball West
· Skate Park
· Soccer East
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE
ID
SIZE
GLOBAL

ELEVATION

ABOVE GLOBAL LEVEL FIXTURE TYPE QTY/POLE
4 A1-A4 70' -
70'

15.5'
QF-900
TLC-BT-575
5 1
2 B1-B2 70' -
70'

15.5'
QF-900
TLC-BT-575
7 1
2 B3-B4 70' -
70'

15.5'
QF-900
TLC-BT-575
6 1
4 C1-C4 70' -
70'

15.5'
QF-900
TLC-BT-575
5 2
4 S1
S3-S4
S6
70' - 70' QF-900 5
2 S2
S5
70' - 70' QF-900 4
2 SK1-SK2 50' - 50' QF-900 2
20 Totals 114
Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage
208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
QF-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3
TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5
*Amp draw based on 100% Įxture output, consult design speciĮc datasheet for adjusted amperage draw chart
Above Global Level is height of fixtures above design (0,0,0) Las Posas Community Park LED Relight
San Marcos,CA
Sales Representative: Karin Anderson · Designed By: D.Lohman · Design No.: 254512A · July 15, 2026 Not to be reproduced in whole or part without the written consent of Musco Lighting. ©1981, 2026 Musco Sports Lighting, LLC.

Sports Illustrated Stadium, Harrison, New Jersey, USA UBS Arena, Elmont, New York, USA Iowa Women of Achievement Bridge, Des Moines, Iowa, USA Tottenham Hotspur FC Training Ground, Tottenham, London, UK

PROJECT SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254512A • 15-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Las Posas Community Park LED Relight
San Marcos,CA

LIGHTING SYSTEM
Structure/Fixture Summary
Structure ID Structure Height Fixt. Attachment Ht. Fixture Qty Fixture Type Load Circuit S5-S8 60' 60' 1 TLC-LED-550 0.54 kW A
60' 1 TLC-LED-900 0.88 kW A
60' 2 TLC-LED-1200 2.34 kW A
4 16 15.04 kW
Circuit Summary
Circuit Description Load Fixture Qty
A Soccer 15.04 kW 16
Fixture Type Summary
Type Circuit Source Wattage Lumens L90 L80 L70 Quantity TLC-LED-1200 A LED 5700K - 75 CRI 1170W 150,000 >120,000 >120,000 >120,000 8 TLC-LED-550 A LED 5700K - 75 CRI 540W 67,000 >120,000 >120,000 >120,000 4 TLC-LED-900 A LED 5700K - 75 CRI 880W 104,000 >120,000 >120,000 >120,000 4 Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage 208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0
TLC-LED-900 5.2 4.9 4.5 3.9 3.1 2.9 2.3
TLC-LED-550 3.2 3.0 2.8 2.4 1.9 1.8 1.4
Light Level Summary
Calculation Grid Summary
Grid Name Calculation Metric Illumination Ave Circuits Fixture Qty Ave Min Max Max/Min Ave/Min Project Spill @ 3ft. Horizontal Illuminance 0.0014 0.00 0.02 - - A 16 Project Spill @ 5ft. Max Candela Metric 102.0546 0.00 847.31 - - A 16 Project Spill @ 5ft. Max Vertical Illuminance Metric 0.0029 0.00 0.03 - - A 16 Soccer Horizontal Illuminance 33.59 27 40 1.48 1.25 A 16 Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254512A • 15-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

S5
S6
S7
S8
32 36
29 38
28 37
38 36
36 35
32 35
37 38
35 37
32 31
37 36
33 29
29 35
34 30
30 28
34 31
40 34
27 38
36 36
34 32
35 40
37 35
28 31
34 31
33 27
33 29
98'
105'
84'
100'
90'
112'
93'
123'
SCALE IN FEET 1 : 50
0' 50' 100'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 S5-S8 60' - 60' TLC-LED-1200 2 2 0
60' TLC-LED-550 1 1 0
60' TLC-LED-900 1 1 0
4 Totals 16 16 0
Above Field Level is height of fixtures above area shown Las Posas Community Park LED Relight
San Marcos,CA
Grid Summary
Name: Soccer
Size: 300' x 150'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid
Guaranteed Average: 30
Scan Average: 33.59
Maximum: 40
Minimum: 27
Avg/Min: 1.25
Guaranteed Max/Min: 2.5
Max/Min: 1.48
UG (adjacent pts): 1.40
CU: 0.80
No. of Points: 50

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 16
Total Load: 15.04 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254512A • 15-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

S5 S6
S7 S8
(0.00', 0.00', -0.02')

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 S5-S8 60' - 60' TLC-LED-1200 2 2 0
60' TLC-LED-550 1 1 0
60' TLC-LED-900 1 1 0
4 Totals 16 16 0
Above Field Level is height of fixtures above area shown Las Posas Community Park LED Relight
San Marcos,CA
Grid Summary
Name: Project Spill @ 3ft.

Spacing: 30.0'
Height: 3.0' above grade
Illumination Summary

INITIAL HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 0.0014
Maximum: 0.02
Minimum: 0.00
CU: 0.00
No. of Points: 62

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 16
Total Load: 15.04 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254512A • 15-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

S5 S6
S7 S8
(0.00', 0.00', -0.02')
2 60 268 543 779 847 584 329 95 5 0
0 0
0 0
105
146
83 13
0 0
0 0
0 0
3 62
71 0
0 0 3 67 249 496 560 371 299 78 2 0 0
33 29
0 0
0 0
1 3
3 0
0 0
0 0
0 19
93 25
0 0
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 S5-S8 60' - 60' TLC-LED-1200 2 2 0
60' TLC-LED-550 1 1 0
60' TLC-LED-900 1 1 0
4 Totals 16 16 0
Above Field Level is height of fixtures above area shown Las Posas Community Park LED Relight
San Marcos,CA
Grid Summary
Name: Project Spill @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL CANDELA (PER FIXTURE)
Entire Grid
Scan Average: 102.0546
Maximum: 847.31
Minimum: 0.00
CU: 0.00
No. of Points: 62

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 16
Total Load: 15.04 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254512A • 15-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

S5 S6
S7 S8
(0.00', 0.00', -0.02')

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 S5-S8 60' - 60' TLC-LED-1200 2 2 0
60' TLC-LED-550 1 1 0
60' TLC-LED-900 1 1 0
4 Totals 16 16 0
Above Field Level is height of fixtures above area shown Las Posas Community Park LED Relight
San Marcos,CA
Grid Summary
Name: Project Spill @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL MAX VERTICAL FOOTCANDLES
Entire Grid
Scan Average: 0.0029
Maximum: 0.03
Minimum: 0.00
CU: 0.00
No. of Points: 62

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 16
Total Load: 15.04 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

EQUIPMENT LAYOUT
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254512A • 15-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Las Posas Community Park LED Relight
San Marcos,CA
Soccer
300' x 150'
S5
S6
S7
S8
(0.00', 0.00', 0.00') (0.00', 0.00', -0.02')
SCALE IN FEET 1 : 30
0' 30' 60'
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Equipment Layout
INCLUDES:
· Soccer
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE
ID
SIZE
GLOBAL

ELEVATION

ABOVE GLOBAL LEVEL FIXTURE TYPE QTY/POLE
4 S5-S8 60' -
60'
60'
60'
TLC-LED-1200
TLC-LED-550
TLC-LED-900
2 1
1 4 Totals 16
Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage
208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
TLC-LED-1200 6.9 6.5 6.0 5.2 4.2 3.8 3.0
TLC-LED-900 5.2 4.9 4.5 3.9 3.1 2.9 2.3
TLC-LED-550 3.2 3.0 2.8 2.4 1.9 1.8 1.4
Above Global Level is height of fixtures above design (0,0,0) Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Sales Representative: Karin Anderson · Designed By: D.Lohman · Design No.: 254515A · July 20, 2026 Not to be reproduced in whole or part without the written consent of Musco Lighting. ©1981, 2026 Musco Sports Lighting, LLC.

Sports Illustrated Stadium, Harrison, New Jersey, USA UBS Arena, Elmont, New York, USA Iowa Women of Achievement Bridge, Des Moines, Iowa, USA Tottenham Hotspur FC Training Ground, Tottenham, London, UK

PROJECT SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA

LIGHTING SYSTEM
Structure/Fixture Summary
Structure ID Structure Height Fixt. Attachment Ht. Fixture Qty Fixture Type Load Circuit A1 60' 60' 5 QF-700 3.35 kW C
60' 4 QF-700 2.68 kW D
18' 1 TLC-BT-575 0.57 kW D
16' 1 TLC-BT-575 0.57 kW C
A2 60' 60' 5 QF-700 3.35 kW C
60' 6 QF-700 4.02 kW B
19' 1 TLC-BT-575 0.57 kW B
16' 1 TLC-BT-575 0.57 kW C
A3 60' 60' 6 QF-700 4.02 kW A
60' 6 QF-700 4.02 kW B
19' 1 TLC-BT-575 0.57 kW A
16' 1 TLC-BT-575 0.57 kW B
A4 60' 60' 5 QF-700 3.35 kW A
60' 4 QF-700 2.68 kW D
18' 1 TLC-BT-575 0.57 kW D
16' 1 TLC-BT-575 0.57 kW A
A5-A6 60' 60' 4 QF-900 3.66 kW G
A13-A14 60' 60' 4 QF-900 3.66 kW F
B1-B2 60' 60' 11 QF-700 7.37 kW C
16' 1 TLC-BT-575 0.57 kW C
B3-B4 70' 70' 11 QF-700 7.37 kW B
16' 1 TLC-BT-575 0.57 kW B
B5-B6 70' 70' 9 QF-700 6.03 kW A
16' 1 TLC-BT-575 0.57 kW A
B7-B8 70' 70' 8 QF-700 5.36 kW D
16' 1 TLC-BT-575 0.57 kW D
C1 60' 60' 2 QF-900 1.50 kW C
C2 60' 60' 6 QF-700 4.02 kW E
C3 60' 60' 2 QF-900 1.50 kW C
C4 60' 60' 5 QF-700 3.35 kW A
16' 2 TLC-BT-575 1.15 kW A
C5 60' 60' 6 QF-700 4.02 kW E
C6 60' 60' 5 QF-700 3.35 kW A
16' 2 TLC-BT-575 1.15 kW A
22 181 123.61 kW
Circuit Summary
Circuit Description Load Fixture Qty
A Field 1 30.73 kW 47
B Field 2 25.08 kW 38
C Field 3 26.74 kW 40
D Field 4 18.38 kW 28
E Field 5 8.04 kW 12
F Field 6 7.32 kW 8
G Field 7 7.32 kW 8
Fixture Type Summary
Type Circuit Source Wattage Lumens L90 L80 L70 Quantity QF-700 A LED 5700K - 75 CRI 670W 87,000 -- -- -- 39
QF-700 B LED 5700K - 75 CRI 670W 87,000 -- -- -- 34
QF-700 C LED 5700K - 75 CRI 670W 87,000 -- -- -- 32
QF-700 D LED 5700K - 75 CRI 670W 87,000 -- -- -- 24
QF-700 E LED 5700K - 75 CRI 670W 87,000 -- -- -- 12
QF-900 C LED 5700K - 75 CRI 750W 89,000 -- -- -- 4
QF-900 F LED 5700K - 75 CRI 915W 117,000 -- -- -- 8
QF-900 G LED 5700K - 75 CRI 915W 117,000 -- -- -- 8
TLC-BT-575 A LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 8 TLC-BT-575 B LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 4 TLC-BT-575 C LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 4 TLC-BT-575 D LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 4 Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage 208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
QF-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3
QF-700 4.0 3.8 3.5 3.0 2.4 2.2 1.7
TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

PROJECT SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Light Level Summary
Calculation Grid Summary
Grid Name Calculation Metric Illumination Ave Circuits Fixture Qty Ave Min Max Max/Min Ave/Min Field 1 (Infield) Horizontal Illuminance 61.15 48 77 1.60 1.27 A 47 Field 1 (Outfield) Horizontal Illuminance 33.92 22 48 2.24 1.58 A 47 Field 2 (Infield) Horizontal Illuminance 60.79 47 74 1.57 1.28 B 38 Field 2 (Outfield) Horizontal Illuminance 39.11 22 49 2.24 1.79 B 38 Field 3 (Infield) Horizontal Illuminance 69.92 51 82 1.60 1.36 C 40 Field 3 (Outfield) Horizontal Illuminance 65.66 41 91 2.20 1.60 C 40 Field 4 (Infield) Horizontal Illuminance 57.71 44 73 1.66 1.31 D 28 Field 4 (Outfield) Horizontal Illuminance 38.75 26 54 2.05 1.47 D 28 Field 5 (Infield) Horizontal Illuminance 25.80 14 36 2.66 1.88 E 12 Field 5 (Outfield) Horizontal Illuminance 30.40 16 47 2.99 1.94 E 12 Field 6 (Infield) Horizontal Illuminance 34.93 28 43 1.51 1.24 F 8 Field 6 (Outfield) Horizontal Illuminance 26.44 20 33 1.66 1.32 F 8 Field 7 (Infield) Horizontal Illuminance 33.57 26 38 1.50 1.31 G 8 Field 7 (Outfield) Horizontal Illuminance 26.81 16 34 2.08 1.63 G 8 Project Spill 150' Offset @ 3ft. Horizontal Illuminance 0.0392 0.00 0.19 1273.267 263.346 A,B,C,D,E,F,G 181 Project Spill 150' Offset @ 5ft. Max Candela Metric 3706.9509 58.24 10714.23 183.965 63.649 A,B,C,D,E,F,G 181 Project Spill 150' Offset @ 5ft. Max Vertical Illuminance Metric 0.1075 0.00 0.42 890.025 228.156 A,B,C,D,E,F,G 181 Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

B6
B5
C6
C4
61 69
66 62
53 41
34 34
32 27
24 26
23 69
77 74
68 54
42 32
28 26
24 29
34 31
22 64
74 70
64 52
45 39
33 31
31 35
39 35
25 56
66 63
57 50
46 43
40 38
38 39
39 37
25 48
56 55
53 48
44 41
40 39
39 37
36 34
22 37
45 48
48 44
39 37
37 38
38 35
34 32
31 36
43 43
40 36
33 33
36 37
36 32
22 35
29 37
41 37
33 30
30 32
32 33
26 35
29 34
38 36
33 29
28 30
31 30
23 32
28 34
39 37
33 30
30 31
31 24
33 34
38 39
36 33
30 30
28 24
38 41
40 39
36 33
29 27
22 34
39 38
37 35
32 29
29 30
31 27
34'
152'
143'
30'
43'
50'
90'
266'
234'
131'
59'
45' A4
A3
SCALE IN FEET 1 : 50
0' 50' 100'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
1 A3 60' - 60' QF-700 6/6* 6 6
19' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 0 1
1 A4 60' - 60' QF-700 5/4* 5 4
18' TLC-BT-575 1 0 1

15.5' TLC-BT-575 1 1 0
2 B5-B6 70' - 70' QF-700 9 9 0

15.5' TLC-BT-575 1 1 0
2 C4
C6 60' - 60' QF-700 5 5 0

15.5' TLC-BT-575 2 2 0
6 Totals 59 47 12
*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Field 1
Size: 260'/265'/260' - basepath 70'
Spacing: 20.0' x 20.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 61.15 33.92
Maximum: 77 48
Minimum: 48 22
Avg/Min: 1.27 1.58
Max/Min: 1.60 2.24
UG (adjacent pts): 1.26 1.58
CU: 0.64
No. of Points: 25 135

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 47
Total Load: 30.73 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

B3
B4
66 69 60 55 47 36 32 32 34 33
72 74 68 64 58 45 39 40 44 44 39
61 69 68 63 58 46 40 43 47 48 44
57 66 64 58 52 44 39 41 46 48 45
51 61 59 53 48 41 37 38 41 44 41
41 49 49 46 43 38 34 33 35 36
38 44 43 41 38 34 31 29 28 26
39 45 46 42 38 33 29 25 22
41 48 49 46 40 33 27 22
37 46 48 46 41 33 25
41 42 42 37
50'
64'
62'
44'
251'
11'
14'
248'
A3
A2
SCALE IN FEET 1 : 50
0' 50' 100'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
1 A2 60' - 60' QF-700 5/6* 6 5
19' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 0 1
1 A3 60' - 60' QF-700 6/6* 6 6
19' TLC-BT-575 1 0 1

15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' QF-700 11 11 0

15.5' TLC-BT-575 1 1 0
4 Totals 51 38 13
*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Field 2
Size: 210'/210'/210' - basepath 70'
Spacing: 20.0' x 20.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 60.79 39.11
Maximum: 74 49
Minimum: 47 22
Avg/Min: 1.28 1.79
Max/Min: 1.57 2.24
UG (adjacent pts): 1.22 1.36
CU: 0.57
No. of Points: 25 77

FIXTURE INFORMATION
Applied Circuits: B
No. of Fixtures: 38
Total Load: 25.08 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

B2
B1
62 74
73 70
70 71
67 56
46 73
82 78
75 75
77 77
74 67
49 68
77 75
69 67
72 78
83 76
53 65
75 72
62 57
60 68
76 71
70 78
70 58
51 52
59 63
58 73
80 73
61 52
51 54
52 72
82 80
69 58
51 47
41 63
83 91
79 61
46 74
84 71
52 C1
C3
46'
54'
40'
153'
153'
40'
50'
61'
34'
176'
173'
62'
A1
A2
SCALE IN FEET 1 : 50
0' 50' 100'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
1 A1 60' - 60' QF-700 5/4* 5 4
18' TLC-BT-575 1 0 1

15.5' TLC-BT-575 1 1 0
1 A2 60' - 60' QF-700 5/6* 5 6
19' TLC-BT-575 1 0 1

15.5' TLC-BT-575 1 1 0
2 B1-B2 60' - 60' QF-700 11 11 0

15.5' TLC-BT-575 1 1 0
2 C1
C3 60' - 60' QF-900 2 2 0
6 Totals 52 40 12
*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Field 3
Size: 175'/170'/165' - basepath 60'
Spacing: 20.0' x 20.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 69.92 65.66
Maximum: 82 91
Minimum: 51 41
Avg/Min: 1.36 1.60
Max/Min: 1.60 2.20
UG (adjacent pts): 1.21 1.44
CU: 0.59
No. of Points: 25 48

FIXTURE INFORMATION
Applied Circuits: C
No. of Fixtures: 40
Total Load: 26.74 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

B7
B8
30 38 46 47 45 54 61 49
33 34 38 47 54 58 60 66 73 64
32 36 42 48 53 58 67 71 70 59
31 39 42 44 47 52 61 67 63 50
36 40 39 40 44 51 55 53 45
28 33 35 37 40 45 50 50 42
26 32 36 40 44 45 46 37
27 35 40 42 40 38
31 39 38 36 32
36 36 27
43'
54'
50'
47'
195'
17'
4'
197'
A1
A4
SCALE IN FEET 1 : 50
0' 50' 100'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A1
A4 60' - 60' QF-700 5/4* 4 5
18' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 0 1
2 B7-B8 70' - 70' QF-700 8 8 0

15.5' TLC-BT-575 1 1 0
4 Totals 40 28 12
*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Field 4
Size: 180'/180'/180' - basepath 60'
Spacing: 20.0' x 20.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 57.71 38.75
Maximum: 73 54
Minimum: 44 26
Avg/Min: 1.31 1.47
Max/Min: 1.66 2.05
UG (adjacent pts): 1.32 1.34
CU: 0.61
No. of Points: 25 53

FIXTURE INFORMATION
Applied Circuits: D
No. of Fixtures: 28
Total Load: 18.38 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

C5
C2
14 15
15 17
22 31
41 22
22 21
23 27
37 47
47 32
29 26
26 29
37 44
41 36
34 30
28 28
33 37
33 29
32 31
30 27
26 27
25 22
29 34
30 25
21 20
21 34
36 30
22 18
30 30
22 16
40'
115'
191'
19'
SCALE IN FEET 1 : 40
0' 40' 80'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 C2
C5 60' - 60' QF-700 6 6 0
2 Totals 12 12 0
Above Field Level is height of fixtures above area shown Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Field 5
Size: 150'/150'/150' - basepath 60'
Spacing: 20.0' x 20.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 25.80 30.40
Maximum: 36 47
Minimum: 14 16
Avg/Min: 1.88 1.94
Max/Min: 2.66 2.99
UG (adjacent pts): 1.58 1.59
CU: 0.61
No. of Points: 25 31

FIXTURE INFORMATION
Applied Circuits: E
No. of Fixtures: 12
Total Load: 8.04 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

A13
A14
42 41 34 34 38 32
40 41 31 30 32 33 32
40 33 29 33 33 30 25
43 36 35 37 35 28 20
28 34 34 34 30 22
21 32 31 28 22
23 24 20
66'
41'
38'
43'
SCALE IN FEET 1 : 40
0' 40' 80'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A13-A14 60' - 60' QF-900 4 4 0
2 Totals 8 8 0
Above Field Level is height of fixtures above area shown Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Field 6
Size: 125'/125'/125' - basepath 60'
Spacing: 20.0' x 20.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 34.93 26.44
Maximum: 43 33
Minimum: 28 20
Avg/Min: 1.24 1.32
Max/Min: 1.51 1.66
UG (adjacent pts): 1.51 1.55
CU: 0.56
No. of Points: 25 16

FIXTURE INFORMATION
Applied Circuits: F
No. of Fixtures: 8
Total Load: 7.32 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC. 32 38
34 31
26 25
26 38
38 33
34 34
33 34
33 35
36 37
37 30
27 29
25 34
35 37
36 29
27 21
32 31
32 33
29 25
16 32
32 31
30 25
21 27
30 29
23 18
26 22
A5
A6
85'
24'
38'
86'
SCALE IN FEET 1 : 40
0' 40' 80'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A5-A6 60' - 60' QF-900 4 4 0
2 Totals 8 8 0
Above Field Level is height of fixtures above area shown Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Field 7
Size: 140'/140'/140' - basepath 60'
Spacing: 20.0' x 20.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 33.57 26.81
Maximum: 38 34
Minimum: 26 16
Avg/Min: 1.31 1.63
Max/Min: 1.50 2.08
UG (adjacent pts): 1.32 1.55
CU: 0.65
No. of Points: 25 25

FIXTURE INFORMATION
Applied Circuits: G
No. of Fixtures: 8
Total Load: 7.32 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

B6
B5
C6
C4
A4
(-108.47', -110.06', -0.10')
B3
B4
A3
(3.93', -109.18', -0.08')
B2
B1
C1
C3
A2
A1
(0.00', 0.00', -0.04')
B7
B8(-103.81', -3.66', -0.06')
C5
C2
(227.04', 304.49', 0.00')
A13
A14
(378.68', 31.13', 0.00')
A5
A6 (193.21', -310.57', -0.02')

0.2 0.1

0.1 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.1 0.0 0.0 0.0

0.0 0.1

0.1 0.1

0.1 0.1

0.1 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.1

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0

0.0 0.0

0.0 0.1

0.2 SCALE IN FEET 1 : 200
0' 200' 400'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A1
A4 60' - 60' QF-700 5/4* 9 0
18' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 1 0
1 A2 60' - 60' QF-700 5/6* 11 0
19' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 1 0
1 A3 60' - 60' QF-700 6/6* 12 0
19' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 1 0
4 A5-A6
A13-A14 60' - 60' QF-900 4 4 0
2 B1-B2 60' - 60' QF-700 11 11 0

15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' QF-700 11 11 0

15.5' TLC-BT-575 1 1 0
2 B5-B6 70' - 70' QF-700 9 9 0

15.5' TLC-BT-575 1 1 0
2 B7-B8 70' - 70' QF-700 8 8 0

15.5' TLC-BT-575 1 1 0
2 C1
C3 60' - 60' QF-900 2 2 0
2 C2
C5 60' - 60' QF-700 6 6 0
2 C4
C6 60' - 60' QF-700 5 5 0

15.5' TLC-BT-575 2 2 0
22 Totals 181 181 0
*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill 150' Offset @ 3ft.

Spacing: 30.0'
Height: 3.0' above grade
Illumination Summary

INITIAL HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 0.0392
Maximum: 0.19
Minimum: 0.00
CU: 0.00
No. of Points: 115

FIXTURE INFORMATION
Applied Circuits: A,B,C,D,E,F,G
No. of Fixtures: 181
Total Load: 123.61 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

B6
B5
C6
C4
A4
(-108.47', -110.06', -0.10')
B3
B4
A3
(3.93', -109.18', -0.08')
B2
B1
C1
C3
A2
A1
(0.00', 0.00', -0.04')
B7
B8(-103.81', -3.66', -0.06')
C5
C2
(227.04', 304.49', 0.00')
A13
A14
(378.68', 31.13', 0.00')
A5
A6 (193.21', -310.57', -0.02')
10714
6408
3269
4474
4817
2521
468
303
258
200
68 58
78 119 379 867 779 1076
2146
2640
3027
4851
5897
5348
4811
2719 1597 3639 2123 5271
5575
6052
3500
2971
2828
2473
2905
2166
1620
528
4455
5644
5445
5541
4032
2727
1998
1337
1464
1404
1200
1079
1547
2474
3279
6326
7255
7947
6722
5496
4611
5622
8483
10513
10386
9175
8357
7474
4433 2762 1387 1242 4561
4347
2892
1749
2597
2437
903
3658
3389
2631
2647 2499
2568
3658
4146
5878
5698
5934
6459
5136
4224
3323
1997
1150
957
914
800
3294
7081
6230
3780
2396
1885
1456
1329
1059
2154 4255
7435
8200
7198
7590
10445
SCALE IN FEET 1 : 200
0' 200' 400'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A1
A4 60' - 60' QF-700 5/4* 9 0
18' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 1 0
1 A2 60' - 60' QF-700 5/6* 11 0
19' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 1 0
1 A3 60' - 60' QF-700 6/6* 12 0
19' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 1 0
4 A5-A6
A13-A14 60' - 60' QF-900 4 4 0
2 B1-B2 60' - 60' QF-700 11 11 0

15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' QF-700 11 11 0

15.5' TLC-BT-575 1 1 0
2 B5-B6 70' - 70' QF-700 9 9 0

15.5' TLC-BT-575 1 1 0
2 B7-B8 70' - 70' QF-700 8 8 0

15.5' TLC-BT-575 1 1 0
2 C1
C3 60' - 60' QF-900 2 2 0
2 C2
C5 60' - 60' QF-700 6 6 0
2 C4
C6 60' - 60' QF-700 5 5 0

15.5' TLC-BT-575 2 2 0
22 Totals 181 181 0
*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill 150' Offset @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL CANDELA (PER FIXTURE)
Entire Grid
Scan Average: 3706.9509
Maximum: 10714.23
Minimum: 58.24
CU: 0.00
No. of Points: 115

FIXTURE INFORMATION
Applied Circuits: A,B,C,D,E,F,G
No. of Fixtures: 181
Total Load: 123.61 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

B6
B5
C6
C4
A4
(-108.47', -110.06', -0.10')
B3
B4
A3
(3.93', -109.18', -0.08')
B2
B1
C1
C3
A2
A1
(0.00', 0.00', -0.04')
B7
B8(-103.81', -3.66', -0.06')
C5
C2
(227.04', 304.49', 0.00')
A13
A14
(378.68', 31.13', 0.00')
A5
A6 (193.21', -310.57', -0.02')

0.4 0.3

0.2 0.1

0.1 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1 0.1 0.1 0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.1 0.1

0.1 0.0

0.0 0.0

0.1 0.0

0.1 0.1

0.1 0.1

0.1 0.1

0.2 0.2

0.3 0.3

0.2 0.3

0.3 0.3

0.4 0.3

0.2 0.2 0.1 0.0 0.0 0.0 0.1

0.1 0.1

0.0 0.0

0.0 0.1

0.3 0.2

0.2 0.1 0.1 0.1

0.1 0.1

0.2 0.2

0.2 0.3

0.2 0.1

0.1 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.0 0.0 0.0

0.1 0.1

0.2 0.3

0.4 SCALE IN FEET 1 : 200
0' 200' 400'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A1
A4 60' - 60' QF-700 5/4* 9 0
18' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 1 0
1 A2 60' - 60' QF-700 5/6* 11 0
19' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 1 0
1 A3 60' - 60' QF-700 6/6* 12 0
19' TLC-BT-575 1 1 0

15.5' TLC-BT-575 1 1 0
4 A5-A6
A13-A14 60' - 60' QF-900 4 4 0
2 B1-B2 60' - 60' QF-700 11 11 0

15.5' TLC-BT-575 1 1 0
2 B3-B4 70' - 70' QF-700 11 11 0

15.5' TLC-BT-575 1 1 0
2 B5-B6 70' - 70' QF-700 9 9 0

15.5' TLC-BT-575 1 1 0
2 B7-B8 70' - 70' QF-700 8 8 0

15.5' TLC-BT-575 1 1 0
2 C1
C3 60' - 60' QF-900 2 2 0
2 C2
C5 60' - 60' QF-700 6 6 0
2 C4
C6 60' - 60' QF-700 5 5 0

15.5' TLC-BT-575 2 2 0
22 Totals 181 181 0
*This structure utilizes a back-to-back mounting configuration Above Field Level is height of fixtures above area shown Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill 150' Offset @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL MAX VERTICAL FOOTCANDLES
Entire Grid
Scan Average: 0.1075
Maximum: 0.42
Minimum: 0.00
CU: 0.00
No. of Points: 115

FIXTURE INFORMATION
Applied Circuits: A,B,C,D,E,F,G
No. of Fixtures: 181
Total Load: 123.61 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

EQUIPMENT LAYOUT
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254515A • 20-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Mission Sports Park Quick Fit LED Retrofit
San Marcos,CA
Field 1
260'/265'/260' - basepath 70'
B6
B5
C6
C4
A4
(-108.47', -110.06', -0.10')
Field 2
210'/210'/210' - basepath 70'
B3
B4
A3
(3.93', -109.18', -0.08')
Field 3
175'/170'/165' - basepath 60'
B2
B1
C1
C3
A2
A1
(0.00', 0.00', -0.04')
Field 4
180'/180'/180' - basepath 60'
B7
B8
(-103.81', -3.66', -0.06')
Field 5
150'/150'/150' - basepath 60'
C5
C2
(227.04', 304.49', 0.00')
Field 6
125'/125'/125' - basepath 60'
A13
A14
(378.68', 31.13', 0.00')
Field 7
140'/140'/140' - basepath 60' A5
A6
(193.21', -310.57', -0.02')
(0.00', 0.00', 0.00')
SCALE IN FEET 1 : 100
0' 100' 200'
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Equipment Layout
INCLUDES:
· Field 1
· Field 2
· Field 3
· Field 4
· Field 5
· Field 6
· Field 7
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE
ID
SIZE
GLOBAL

ELEVATION

ABOVE GLOBAL LEVEL FIXTURE TYPE QTY/POLE
2 A1
A4
60' -
60'
18'

15.5'
QF-700
TLC-BT-575
TLC-BT-575
5/4*
1 1
1 A2 60' -
60'
19'

15.5'
QF-700
TLC-BT-575
TLC-BT-575
5/6*
1 1
1 A3 60' -
60'
19'

15.5'
QF-700
TLC-BT-575
TLC-BT-575
6/6*
1 1
4 A5-A6
A13-A14
60' - 60' QF-900 4
2 B1-B2 60' -
60'

15.5'
QF-700
TLC-BT-575
11 1
2 B3-B4 70' -
70'

15.5'
QF-700
TLC-BT-575
11 1
2 B5-B6 70' -
70'

15.5'
QF-700
TLC-BT-575
9 1
2 B7-B8 70' -
70'

15.5'
QF-700
TLC-BT-575
8 1
2 C1
C3
60' - 60' QF-900 2
2 C2
C5
60' - 60' QF-700 6
2 C4
C6
60' -
60'

15.5'
QF-700
TLC-BT-575
5 2
22 Totals 181
Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage
208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
QF-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3
QF-700 4.0 3.8 3.5 3.0 2.4 2.2 1.7
TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5
*This structure utilizes a back-to-back mounting configuration Above Global Level is height of fixtures above design (0,0,0) San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Sales Representative: Karin Anderson · Designed By: D.Lohman · Design No.: 247745A · July 16, 2026 Not to be reproduced in whole or part without the written consent of Musco Lighting. ©1981, 2026 Musco Sports Lighting, LLC.

Sports Illustrated Stadium, Harrison, New Jersey, USA UBS Arena, Elmont, New York, USA Iowa Women of Achievement Bridge, Des Moines, Iowa, USA Tottenham Hotspur FC Training Ground, Tottenham, London, UK

PROJECT SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA

LIGHTING SYSTEM
Structure/Fixture Summary
Structure ID Structure Height Fixt. Attachment Ht. Fixture Qty Fixture Type Load Circuit A1 70' 70' 7 QF-700 4.69 kW A
21' 2 TLC-BT-575 1.15 kW A
A2 80' 80' 12 QF-700 8.04 kW A
22' 1 TLC-BT-575 0.57 kW A
A3-A4 80' 80' 7 QF-700 4.69 kW A
21' 1 TLC-BT-575 0.57 kW A
A5 80' 80' 12 QF-700 8.04 kW A
22' 1 TLC-BT-575 0.57 kW A
A6 70' 70' 7 QF-700 4.69 kW A
21' 2 TLC-BT-575 1.15 kW A
B1 70' 70' 7 QF-700 4.69 kW B
21' 2 TLC-BT-575 1.15 kW B
B2 80' 80' 12 QF-700 8.04 kW B
22' 1 TLC-BT-575 0.57 kW B
B3-B4 80' 80' 7 QF-700 4.69 kW B
21' 1 TLC-BT-575 0.57 kW B
B5 80' 80' 12 QF-700 8.04 kW B
22' 1 TLC-BT-575 0.57 kW B
B6 70' 70' 7 QF-700 4.69 kW B
21' 2 TLC-BT-575 1.15 kW B
C1-C4 70' 70' 9 QF-700 6.03 kW C
16 156 103.00 kW
Circuit Summary
Circuit Description Load Fixture Qty
A Baseball 1 39.44 kW 60
B Baseball 2 39.44 kW 60
C Soccer 24.12 kW 36
Fixture Type Summary
Type Circuit Source Wattage Lumens L90 L80 L70 Quantity QF-700 A LED 5700K - 75 CRI 670W 87,000 -- -- -- 52
QF-700 B LED 5700K - 75 CRI 670W 87,000 -- -- -- 52
QF-700 C LED 5700K - 75 CRI 670W 87,000 -- -- -- 36
TLC-BT-575 A LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 8 TLC-BT-575 B LED 5700K - 75 CRI 575W 52,000 >120,000 >120,000 >120,000 8 Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage 208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
QF-700 4.0 3.8 3.5 3.0 2.4 2.2 1.7
TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5
Light Level Summary
Calculation Grid Summary
Grid Name Calculation Metric Illumination Ave Circuits Fixture Qty Ave Min Max Max/Min Ave/Min Baseball 1 (Infield) Horizontal Illuminance 50.70 37 65 1.73 1.35 A 60 Baseball 1 (Outfield) Horizontal Illuminance 33.76 24 45 1.84 1.39 A 60 Baseball 2 (Infield) Horizontal Illuminance 50.64 38 65 1.72 1.34 B 60 Baseball 2 (Outfield) Horizontal Illuminance 34.62 23 41 1.79 1.51 B 60 Project Spill 150' Offset 1 @ 3ft. Horizontal Illuminance 0.0433 0.00 0.19 582.604 135.011 B,C 96 Project Spill 150' Offset 1 @ 5ft. Max Candela Metric 2227.1077 22.72 8034.25 353.610 98.021 B,C 96 Project Spill 150' Offset 1 @ 5ft. Max Vertical Illuminance Metric 0.0940 0.00 0.35 728.477 193.746 B,C 96 Project Spill 150' Offset 2 @ 3ft. Horizontal Illuminance 0.0660 0.02 0.15 8.503 3.821 A 60 Project Spill 150' Offset 2 @ 5ft. Max Candela Metric 2902.3213 806.94 6102.51 7.563 3.597 A 60 Project Spill 150' Offset 2 @ 5ft. Max Vertical Illuminance Metric 0.1452 0.05 0.29 5.387 2.708 A 60 Soccer Horizontal Illuminance 37.82 30 46 1.51 1.26 C 36 Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

A3
A4
A5
A2
A6
A1
54 55
50 47
45 41
35 30
27 26
56 65
58 52
50 43
42 36
34 38
29 48
58 60
56 49
43 36
36 39
40 31
41 50
54 53
48 43
39 37
36 32
32 37
44 48
46 41
36 33
32 30
28 30
39 44
43 45
37 31
27 27
28 27
28 37
44 37
41 36
30 28
30 32
27 32
37 34
41 36
32 31
33 32
26 29
34 39
34 31
35 36
27 24
34 37
32 30
30 31
28 32
28 30
31 310'
113'
32'
59'
170'
31'
47'
38'
24'
179'
131'
305'
SCALE IN FEET 1 : 60
0' 60' 120'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A1
A6 70' - 70' QF-700 7 7 0

20.5' TLC-BT-575 2 2 0
2 A2
A5 80' - 80' QF-700 12 12 0

21.5' TLC-BT-575 1 1 0
2 A3-A4 80' - 80' QF-700 7 7 0

20.5' TLC-BT-575 1 1 0
6 Totals 60 60 0
Above Field Level is height of fixtures above area shown San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Grid Summary
Name: Baseball 1
Size: 300'/320'/300' - basepath 90'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 50.70 33.76
Maximum: 65 45
Minimum: 37 24
Avg/Min: 1.35 1.39
Max/Min: 1.73 1.84
UG (adjacent pts): 1.21 1.46
CU: 0.72
No. of Points: 25 80

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 60
Total Load: 39.44 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports Ligh Ɵng, LLC.

B3
B4
B5
B2
B6
B1
42 56
54 47
39 39
40 38
34 31
49 65
63 55
47 40
41 40
35 40
34 48
58 62
59 50
41 37
38 36
36 27
43 54
56 51
46 40
38 40
37 30
23 38
52 52
44 39
34 36
38 32
31 37
41 41
37 32
29 31
36 34
31 39
40 33
34 31
29 33
37 37
38 40
34 36
33 31
33 35
34 30
35 38
40 33
32 34
32 29
39 40
38 29
29 31
25 32
32 28
28 29
277'
116'
35'
49'
31'
184'
182'
34'
122'
304'
54'
52'
SCALE IN FEET 1 : 60
0' 60' 120'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 B1
B6 70'
- 70' QF-700770

20.5' TLC-BT-575220
2 B2
B5 80'
- 80' QF-700 12 120

21.5' TLC-BT-575110
2 B3-B4 80'- 80' QF-700770

20.5' TLC-BT-575110
6 Totals 60 600
Above Field Level is height of fixtures above area shown San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Grid Summary
Name: Baseball 2
Size: Irregular 300'/300'/300'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Infield Outfield
Scan Average: 50.64 34.62
Maximum: 65 41
Minimum: 38 23
Avg/Min: 1.34 1.51
Max/Min: 1.72 1.79
UG (adjacent pts): 1.37 1.37
CU: 0.72
No. of Points: 25 77

FIXTURE INFORMATION
Applied Circuits:

B
No. of Fixtures: 60
Total Load: 39.44 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports Ligh Ɵng, LLC.

C3
C1
C4
C2
37 41
34 32
39 44
36 35
41 41
39 44
41 36
35 43
41 39
43 41
33 37
42 40
37 41
42 33
34 41
37 34
39 42
31 32
41 36
33 38
42 30
35 40
35 33
37 40
32 34
37 37
35 39
37 32
36 42
42 39
41 38
35 42
46 39
35 38
41 35
112'
101'
123'
106'
114'
100'
126'
99'
SCALE IN FEET 1 : 50
0' 50' 100'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 C1-C4 70'- 70' QF-700990
4 Totals 36 360
Above Field Level is height of fixtures above area shown San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Grid Summary
Name: Soccer
Size: 300' x 190'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 37.82
Maximum: 46
Minimum: 30
Avg/Min: 1.26
Max/Min: 1.51
UG (adjacent pts): 1.38
CU: 0.75
No. of Points: 70

FIXTURE INFORMATION
Applied Circuits:

C
No. of Fixtures: 36
Total Load: 24.12 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

A3
A4 A5
A2
A6
A1
(0.00', 0.00', -0.02')
B3
B4
B5
B2
B6
B1
(679.32', -197.91', 0.00')
C3
C1
C4
C2
(700.00', 394.21', 0.00')

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.1

0.1 0.1

0.1 0.0

0.0 0.1

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0

0.0 0.1

0.1 0.1

0.0 0.0

0.1 0.1

0.2 0.2

0.2 0.2

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.2

0.1 0.1

0.1 0.1

0.1 0.1

0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0
SCALE IN FEET 1 : 150
0' 150' 300'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 B1
B6 70' - 70' QF-700 7 7 0

20.5' TLC-BT-575 2 2 0
2 B2
B5 80' - 80' QF-700 12 12 0

21.5' TLC-BT-575 1 1 0
2 B3-B4 80' - 80' QF-700 7 7 0

20.5' TLC-BT-575 1 1 0
4 C1-C4 70' - 70' QF-700 9 9 0
10 Totals 96 96 0
Above Field Level is height of fixtures above area shown San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Grid Summary
Name: Project Spill 150' Offset 1 @ 3ft.

Spacing: 30.0'
Height: 3.0' above grade
Illumination Summary

INITIAL HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 0.0433
Maximum: 0.19
Minimum: 0.00
CU: 0.00
No. of Points: 114

FIXTURE INFORMATION
Applied Circuits: B,C
No. of Fixtures: 96
Total Load: 63.56 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

A3
A4 A5
A2
A6
A1
(0.00', 0.00', -0.02')
B3
B4
B5
B2
B6
B1
(679.32', -197.91', 0.00')
C3
C1
C4
C2
(700.00', 394.21', 0.00')
1486
2497
2685
4043
5486
6204
4528
5593
5246
3591
3680
3689
4339
4563
4381
4710
4437
6066
7154
8034
7172
5319
3334
2706
1731
1329
1134
1453
1021 1648 644
1947
1974
2223
1817
686
1207
1828
1880
4162
5856
5923
5291
4411
4587
4266
3573
3538
3502
3689
4150
4394
5865
4156
1713
1887
1519
3647
5939
1898 907 645 603 408
468
422
152
47 335
595
426
637
1124
1507
1353
917
721
408
363
106
135
580
558
212
23 335
641 734 885 1207 1507 1994 1847 1638 1234 956
830
473
97 400
628
389
42 158
321
466
808
1070
1004
672
408
272
559
1227
SCALE IN FEET 1 : 150
0' 150' 300'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 B1
B6 70' - 70' QF-700 7 7 0

20.5' TLC-BT-575 2 2 0
2 B2
B5 80' - 80' QF-700 12 12 0

21.5' TLC-BT-575 1 1 0
2 B3-B4 80' - 80' QF-700 7 7 0

20.5' TLC-BT-575 1 1 0
4 C1-C4 70' - 70' QF-700 9 9 0
10 Totals 96 96 0
Above Field Level is height of fixtures above area shown San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Grid Summary
Name: Project Spill 150' Offset 1 @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL CANDELA (PER FIXTURE)
Entire Grid
Scan Average: 2227.1077
Maximum: 8034.25
Minimum: 22.72
CU: 0.00
No. of Points: 114

FIXTURE INFORMATION
Applied Circuits: B,C
No. of Fixtures: 96
Total Load: 63.56 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

A3
A4 A5
A2
A6
A1
(0.00', 0.00', -0.02')
B3
B4
B5
B2
B6
B1
(679.32', -197.91', 0.00')
C3
C1
C4
C2
(700.00', 394.21', 0.00')

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.2

0.2 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.0

0.0 0.1 0.0

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.2

0.3 0.3

0.4 0.3

0.3 0.3

0.3 0.3

0.2 0.3

0.3 0.3

0.3 0.3

0.2 0.2

0.1 0.1

0.1 0.2

0.1 0.1 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.1

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.1 0.1 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.1 0.0

0.0 0.0

0.0 0.1
SCALE IN FEET 1 : 150
0' 150' 300'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 B1
B6 70' - 70' QF-700 7 7 0

20.5' TLC-BT-575 2 2 0
2 B2
B5 80' - 80' QF-700 12 12 0

21.5' TLC-BT-575 1 1 0
2 B3-B4 80' - 80' QF-700 7 7 0

20.5' TLC-BT-575 1 1 0
4 C1-C4 70' - 70' QF-700 9 9 0
10 Totals 96 96 0
Above Field Level is height of fixtures above area shown San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Grid Summary
Name: Project Spill 150' Offset 1 @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL MAX VERTICAL FOOTCANDLES
Entire Grid
Scan Average: 0.0940
Maximum: 0.35
Minimum: 0.00
CU: 0.00
No. of Points: 114

FIXTURE INFORMATION
Applied Circuits: B,C
No. of Fixtures: 96
Total Load: 63.56 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

A3
A4 A5
A2
A6
A1
(0.00', 0.00', -0.02')
B3
B4
B5
B2
B6
B1
(679.32', -197.91', 0.00')
C3
C1
C4
C2
(700.00', 394.21', 0.00')

0.1 0.1 0.1 0.1 0.1 0.1 0.0 0.1 0.1 0.1 0.1 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.1 0.1

0.1 0.1

0.0 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1
SCALE IN FEET 1 : 150
0' 150' 300'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A1
A6 70' - 70' QF-700 7 7 0

20.5' TLC-BT-575 2 2 0
2 A2
A5 80' - 80' QF-700 12 12 0

21.5' TLC-BT-575 1 1 0
2 A3-A4 80' - 80' QF-700 7 7 0

20.5' TLC-BT-575 1 1 0
6 Totals 60 60 0
Above Field Level is height of fixtures above area shown San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Grid Summary
Name: Project Spill 150' Offset 2 @ 3ft.

Spacing: 30.0'
Height: 3.0' above grade
Illumination Summary

INITIAL HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 0.0660
Maximum: 0.15
Minimum: 0.02
CU: 0.00
No. of Points: 68

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 60
Total Load: 39.44 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

A3
A4 A5
A2
A6
A1
(0.00', 0.00', -0.02')
B3
B4
B5
B2
B6
B1
(679.32', -197.91', 0.00')
C3
C1
C4
C2
(700.00', 394.21', 0.00')
3901 4132 5831 4043 1493 1391 807 815 2209 2889 2644 2360 2102
1480
1411
1323
1412
1541
3343
2011
1421
1647
1955
2066
1917
3567
4020
3865
3916
3804
2780
3462
3309
3293
2263
3369
4225
5282
4241 3130 2192 2284 2368 2342
1304
1369
1596
1992
2752
4387
5426
6103
3542
2219
3046
2303
1637
4199
5596
4460
4183
3410
2984
2882
2815
2899
3115
3287
SCALE IN FEET 1 : 150
0' 150' 300'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A1
A6 70' - 70' QF-700 7 7 0

20.5' TLC-BT-575 2 2 0
2 A2
A5 80' - 80' QF-700 12 12 0

21.5' TLC-BT-575 1 1 0
2 A3-A4 80' - 80' QF-700 7 7 0

20.5' TLC-BT-575 1 1 0
6 Totals 60 60 0
Above Field Level is height of fixtures above area shown San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Grid Summary
Name: Project Spill 150' Offset 2 @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL CANDELA (PER FIXTURE)
Entire Grid
Scan Average: 2902.3213
Maximum: 6102.51
Minimum: 806.94
CU: 0.00
No. of Points: 68

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 60
Total Load: 39.44 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

A3
A4 A5
A2
A6
A1
(0.00', 0.00', -0.02')
B3
B4
B5
B2
B6
B1
(679.32', -197.91', 0.00')
C3
C1
C4
C2
(700.00', 394.21', 0.00')

0.3 0.3 0.3 0.3 0.2 0.1 0.1 0.1 0.1 0.1 0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.2

0.3 0.3

0.2 0.2

0.2 0.2

0.1 0.1

0.1 0.1

0.1 0.1 0.1 0.1 0.1 0.1

0.1 0.1

0.1 0.1

0.1 0.1

0.2 0.2

0.2 0.1

0.1 0.1

0.2 0.3

0.3 0.2

0.2 0.2

0.2 0.2

0.2 0.2

0.2 0.3
SCALE IN FEET 1 : 150
0' 150' 300'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 A1
A6 70' - 70' QF-700 7 7 0

20.5' TLC-BT-575 2 2 0
2 A2
A5 80' - 80' QF-700 12 12 0

21.5' TLC-BT-575 1 1 0
2 A3-A4 80' - 80' QF-700 7 7 0

20.5' TLC-BT-575 1 1 0
6 Totals 60 60 0
Above Field Level is height of fixtures above area shown San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Grid Summary
Name: Project Spill 150' Offset 2 @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL MAX VERTICAL FOOTCANDLES
Entire Grid
Scan Average: 0.1452
Maximum: 0.29
Minimum: 0.05
CU: 0.00
No. of Points: 68

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 60
Total Load: 39.44 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

EQUIPMENT LAYOUT
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #247745A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

San Elijo Community Park Quick Fit LED Retrofit
San Marcos, CA
Baseball 1
300'/320'/300' - basepath 90'
A3
A4 A5
A2
A6
A1
(0.00', 0.00', -0.02')
Baseball 2
Irregular
B3
B4
B5
B2
B6
B1
(679.32', -197.91', 0.00')
Soccer
300' x 190'
C3
C1
C4
C2
(700.00', 394.21', 0.00')
(0.00', 0.00', 0.00')
SCALE IN FEET 1 : 110
0' 110' 220'
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Equipment Layout
INCLUDES:
· Baseball 1
· Baseball 2
· Soccer
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE
ID
SIZE
GLOBAL

ELEVATION

ABOVE GLOBAL LEVEL FIXTURE TYPE QTY/POLE
4 A1
A6
B1
B6
70' -
70'

20.5'
QF-700
TLC-BT-575
7 2
4 A2
A5
B2
B5
80' -
80'

21.5'
QF-700
TLC-BT-575
12 1
4 A3-A4
B3-B4
80' -
80'

20.5'
QF-700
TLC-BT-575
7 1
4 C1-C4 70' - 70' QF-700 9
16 Totals 156
Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage
208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
QF-700 4.0 3.8 3.5 3.0 2.4 2.2 1.7
TLC-BT-575 3.3 3.2 2.9 2.5 2.0 1.8 1.5
Above Global Level is height of fixtures above design (0,0,0) Sunset Park Quick Fit LED Retrofit
San Marcos,CA
Sales Representative: Karin Anderson · Designed By: D.Lohman · Design No.: 254514A · July 16, 2026 Not to be reproduced in whole or part without the written consent of Musco Lighting. ©1981, 2026 Musco Sports Lighting, LLC.

Sports Illustrated Stadium, Harrison, New Jersey, USA UBS Arena, Elmont, New York, USA Iowa Women of Achievement Bridge, Des Moines, Iowa, USA Tottenham Hotspur FC Training Ground, Tottenham, London, UK

PROJECT SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254514A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Sunset Park Quick Fit LED Retrofit
San Marcos,CA

LIGHTING SYSTEM
Structure/Fixture Summary
Structure ID Structure Height Fixt. Attachment Ht. Fixture Qty Fixture Type Design Load Circuit S1-S2 60' 60' 7 QF-900 6.24 kW A
S3-S4 70' 70' 7 QF-900 6.24 kW A
S5-S8 50' 50' 2 QF-900 1.62 kW B
8 36 31.42 kW
*Fixtures in this design have dimmed output values to meet design specific needs.

Circuit Summary
Circuit Description Design Load Fixture Qty
A Soccer 24.96 kW 28
B Arena Soccer 6.46 kW 8
Fixture Type Summary
Type Circuit Source Avg. Wattage Avg. Lumens L90 L80 L70 Quantity QF-900 A LED 5700K - 75 CRI 891W 113,000 -- -- -- 28
QF-900 B LED 5700K - 75 CRI 807W 105,356 -- -- -- 8
Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage 208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
QF-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3
*Amp draw based on 100% fixture output, consult design specific datasheet for adjusted amperage draw chart Light Level Summary
Calculation Grid Summary
Grid Name Calculation Metric Illumination Ave Circuits Fixture Qty Ave Min Max Max/Min Ave/Min Arena Soccer Horizontal Illuminance 30.85 22 41 1.86 1.39 B 8 Project Spill 150' Offset @ 3ft. Horizontal Illuminance 0.0110 0.00 0.06 - - A 28 Project Spill 150' Offset @ 5ft. Max Candela Metric 1441.4408 90.48 5770.80 63.783 15.932 A,B 36 Project Spill 150' Offset @ 5ft. Max Vertical Illuminance Metric 0.0404 0.00 0.15 73.477 19.189 A,B 36 Soccer Horizontal Illuminance 30.17 21 38 1.78 1.41 A 28 Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254514A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

S1 S2
S4 S3
30 34
27 24
29 37
30 37
37 31
26 30
36 38
36 35
32 27
31 33
34 31
32 31
27 29
31 30
25 33
31 29
28 29
26 23
31 30
27 26
25 22
22 30
30 26
26 25
21 24
31 30
28 29
29 26
29 32
33 29
30 31
29 34
35 33
28 32
32 34
36 36
31 27
31 35
36 31
34 26
25 29
36 30
119'
120'
120'
123'
111'
115'
111'
124'
SCALE IN FEET 1 : 50
0' 50' 100'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 S1-S2 60' 3' 63' QF-900 7 7 0
2 S3-S4 70' -5' 65' QF-900 7 7 0
4 Totals 28 28 0
Above Field Level is height of fixtures above area shown Sunset Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Soccer
Size: 340' x 200'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 30.17
Maximum: 38
Minimum: 21
Avg/Min: 1.41
Max/Min: 1.78
UG (adjacent pts): 1.32
CU: 0.78
No. of Points: 84

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 28
Total Load: 24.96 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254514A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC. 22 33
22 33
35 30
30 33
29 28
41 30
29 34
26 29
32 31
27 41
30 S5
S6
S7
S8
63'
56'
65'
43'
64'
74'
73'
64'
SCALE IN FEET 1 : 40
0' 40' 80'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
4 S5-S8 50' - 50' QF-900 2 2 0
4 Totals 8 8 0
Above Field Level is height of fixtures above area shown Sunset Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Arena Soccer
Size: 200' x 85'
Spacing: 30.0' x 30.0'
Height: 3.0' above grade
Illumination Summary

MAINTAINED HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 30.85
Maximum: 41
Minimum: 22
Avg/Min: 1.39
Max/Min: 1.86
UG (adjacent pts): 1.51
CU: 0.70
No. of Points: 21

FIXTURE INFORMATION
Applied Circuits: B
No. of Fixtures: 8
Total Load: 6.46 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254514A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

S1 S2
S4 S3
S5
S6
S7
S8
(103.79', -224.90', 0.00')

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.1

0.1 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 S1-S2 60' 3' 63' QF-900 7 7 0
2 S3-S4 70' -5' 65' QF-900 7 7 0
4 Totals 28 28 0
Above Field Level is height of fixtures above area shown Sunset Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill 150' Offset @ 3ft.

Spacing: 30.0'
Height: 3.0' above grade
Illumination Summary

INITIAL HORIZONTAL FOOTCANDLES
Entire Grid
Scan Average: 0.0110
Maximum: 0.06
Minimum: 0.00
CU: 0.00
No. of Points: 78

FIXTURE INFORMATION
Applied Circuits: A
No. of Fixtures: 28
Total Load: 24.96 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254514A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

S1 S2
S4 S3
S5
S6
S7
S8
(103.79', -224.90', 0.00')
2201
928
1027
1432
2160
2683
1968
1412
474
1468
1854
1369
1761
1053
329
536
173
711 645 266
623
470
494
678
1195
1919
2477
2730
2235
612 1191
472
421
275
136
327
974
2783
5101
5648
5074
5117
5771
5214
2727
1057
346
360
453
333
90 148 238 517 831 1059 1192 1336 1305 1106 929 658 383 267 188 238
531
583
429
304
915
2191
1804
2588
2636
2632
2853
2818
SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 S1-S2 60' 3' 63' QF-900 7 7 0
2 S3-S4 70' -5' 65' QF-900 7 7 0
4 S5-S8 50' - 50' QF-900 2 2 0
8 Totals 36 36 0
Above Field Level is height of fixtures above area shown Sunset Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill 150' Offset @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL CANDELA (PER FIXTURE)
Entire Grid
Scan Average: 1441.4408
Maximum: 5770.80
Minimum: 90.48
CU: 0.00
No. of Points: 78

FIXTURE INFORMATION
Applied Circuits: A,B
No. of Fixtures: 36
Total Load: 31.42 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

ILLUMINATION SUMMARY
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254514A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

S1 S2
S4 S3
S5
S6
S7
S8
(103.79', -224.90', 0.00')

0.1 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.0

0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.1 0.2

0.2 0.1

0.1 0.1

0.0 0.0

0.0 0.0

0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.1 0.1 0.1 0.1 0.0 0.0 0.0 0.0 0.0

0.0 0.0

0.0 0.0

0.0 0.0

0.1 0.1

0.1 0.1

0.1 0.1

0.1 SCALE IN FEET 1 : 100
0' 100' 200'
Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE ID SIZE GRADE

ELEVATION

ABOVE FIELD

LEVEL FIXTURE TYPE QTY/POLE THISGRID
OTHER
GRIDS
2 S1-S2 60' 3' 63' QF-900 7 7 0
2 S3-S4 70' -5' 65' QF-900 7 7 0
4 S5-S8 50' - 50' QF-900 2 2 0
8 Totals 36 36 0
Above Field Level is height of fixtures above area shown Sunset Park Quick Fit LED Retrofit
San Marcos,CA
Grid Summary
Name: Project Spill 150' Offset @ 5ft.

Spacing: 30.0'
Height: 5.0' above grade
Illumination Summary

INITIAL MAX VERTICAL FOOTCANDLES
Entire Grid
Scan Average: 0.0404
Maximum: 0.15
Minimum: 0.00
CU: 0.00
No. of Points: 78

FIXTURE INFORMATION
Applied Circuits: A,B
No. of Fixtures: 36
Total Load: 31.42 kW
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Guaranteed Performance: The ILLUMINATION described above is guaranteed per your Musco Warranty document.

Field Measurements: Individual field measurements may vary from computer-calculated predictions.

Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

EQUIPMENT LAYOUT
Not to be reproduced in whole or part without the wriƩen consent of Musco Sports LighƟng, LLC.

ENGINEERED DESIGN By: D.Lohman • File #254514A • 16-Jul-26 ©1981, 2026 Musco Sports LighƟng, LLC.

Sunset Park Quick Fit LED Retrofit
San Marcos,CA
S1 S2
S4 S3
S5
S6
S7
S8
(103.79', -224.90', 0.00')
(0.00', 0.00', 0.00')
SCALE IN FEET 1 : 60
0' 60' 120'
Pole location(s) dimensions are relative
to 0,0 reference point(s)
Equipment Layout
INCLUDES:
· Arena Soccer
· Soccer
Electrical System Requirements: Refer to Amperage
Draw Chart and/or the "Musco Control System Summary"
for electrical sizing.

Installation Requirements: Results assume ± 3%
nominal voltage at line side of the driver and structures located within 3 feet (1m) of design locations.

Equipment List For Areas Shown
Structure Fixtures

QTY STRUCTURE
ID
SIZE
GLOBAL

ELEVATION

ABOVE GLOBAL LEVEL FIXTURE TYPE QTY/POLE
2 S1-S2 60' 3' 63' QF-900 7
2 S3-S4 70' -5' 65' QF-900 7
4 S5-S8 50' - 50' QF-900 2
8 Totals 36
Single Fixture Amperage Draw Chart
Driver SpeciĮcaƟons
(.90 min power factor)
Line Amperage Per Fixture
(max draw)
Single Phase Voltage
208
(60)
220
(60)
240
(60)
277
(60)
347
(60)
380
(60)
480
(60)
QF-900 5.3 5.0 4.6 4.0 3.2 2.9 2.3
*Amp draw based on 100% Įxture output, consult design speciĮc datasheet for adjusted amperage draw chart