ORDINANCE NO. O-25-1421

AN ORDINANCE OF THE CITY OF SAN MARINO ADOPTING BY
REFERENCE THE 2025 EDITIONS OF THE CALIFORNIA

ADMINISTRATIVE, BUILDING, MECHANICAL, PLUMBING,

ELECTRICAL, RESIDENTIAL, FIRE, ENERGY, GREEN BUILDING

STANDARDS, HISTORICAL BUILDING, EXISTING BUILDING,

APPENDIX J LOS ANGELES COUNTY GRADING STANDARDS AND

REFERENCED STANDARDS CODES, WITH CERTAIN AMENDMENTS,
DELETIONS AND ADDITIONS, AND AMENDING CHAPTER 25 OF THE

SAN MARINO MUNICIPAL CODE

THE CITY COUNCIL OF THE CITY OF SAN MARINO DOES ORDAIN
AS FOLLOWS:

SECTION 1. RECITALS
WHEREAS, the City Council of the City of San Marino does hereby find that there is a need to enforce the most current editions of the California Building Standards Code, with local amendments thereof, as recited herein for regulating and controlling the design, erection, construction, enlargement, installation, alteration, repair, relocation, removal, use and occupancy, demolition, conversion, height and area, location and maintenance, and quality of materials of all buildings and structures and plumbing, mechanical, electrical and fire suppression systems and certain equipment within the City; and
WHEREAS, The City of San Marino is located in an area subject to climatic conditions with long periods of low humidity and hot weather, combined with unpredictable seasonal Santa Ana high wind conditions resulting in increased exposure to fire risk; and WHEREAS, the City Council does hereby further find that in accordance with section 15061(b)(3) of the California Code of Regulations, the adoption of these local amendments to the California Building Standards Code, and amendments to the San Marino Municipal Code are exempt from the provisions of the California Environmental Quality Act because such actions are administrative in nature; and
WHEREAS, the City Council does hereby further find that in accordance with section15061 (b)(3) of the California Code of Regulations, the adoption of these local amendments to the California Building Standards Code, and amendments to the San Marino Municipal Code are exempt from the provisions of the California Environmental Quality Act because such actions are largely administrative in nature, are designed to improve and not degrade environmental quality, and the impacts of these local amendments to the building standards code will not adversely affect the environment in any manner that could be significant.

Section 1. Articles 02 through 06, 09, 10, 12, 13, and 14 of Chapter 25, the “Uniform Codes” of the San Marino City Code, adopting by reference the 2016 Editions of the California Building, Mechanical, Plumbing, Electrical, Energy, Green Building Standards, Appendix J Los Angeles County Grading Standards, Referenced Standards, and Fire Codes, and amendments thereto, are hereby repealed; provided, however, that such repeal shall not affect or excuse any violation of any of said codes occurring prior to the effective date of this ordinance.

Section 2. New Article 02 Building Code is hereby added to Chapter 25 of the San Marino City Code to read as follows with additions identified in red font:

CHAPTER XXV

UNIFORM CODES
ARTICLE 01

GENERAL PROVISIONS
SECTION:

25.01.01: Permits Required

25.01.02: Times Construction Prohibited

25.01.03: Work By Owner Permitted

25.01.04: Penalty For Violations

25.01.05: Property Owner Responsible

25.01.06: Property Maintenance Standards For Construction Projects

25.01.07: Expedited Electric Vehicle Charging Station Permitting

25.01.08: Definitions

25.01.09: Limitation On Authority - Board Of Appeals

25.01.10: Adoption Of Administrative Regulations

25.01.01: PERMITS REQUIRED:

It shall be unlawful for any person to begin or perform any construction work or construction activity or to cause or permit any construction work or construction activity, for which a permit is required by this chapter, to begin or perform on any residential or commercial parcel of property without having first obtained said permit. (Ord. 092-1015, 6-10-1992)

25.01.02: TIMES CONSTRUCTION PROHIBITED:

It shall be unlawful for any person to perform or to cause or permit to be performed any construction work or construction activity for which a permit is required by this chapter or for any person requiring a business license pursuant to chapter XI of this Code to perform or to cause or permit to be performed any construction work or construction activity on the following days: (Ord. 092-1015, 6-10-1992)
A. On Mondays through Fridays, before seven o'clock (7:00) A.M. and after six o'clock (6:00) P.M.; except, that the Director of Planning and BuildingCommunity Development Director may authorize, in connection with seismic upgrading or fire sprinkler installation, construction work or activity in the C-1 Zone to be performed outside between six o'clock (6:00) P.M. and nine o'clock (9:00) P.M. and inside an enclosed building after nine o'clock (9:00) P.M. Such construction work or activity shall be performed in compliance with any conditions the Director of Planning and BuildingCommunity Development Director shall impose to alleviate potential disturbance to surrounding properties.

B. On Saturdays, before nine o'clock (9:00) A.M. and after four o'clock (4:00) P.M.; except, that the Director of Planning and BuildingCommunity Development Director may authorize, in connection with seismic upgrading or fire sprinkler installation, construction work or activity in the C-1 Zone to be performed outside between four o'clock (4:00) P.M. and nine o'clock (9:00) P.M. and inside an enclosed building after nine o'clock (9:00) P.M. Such construction work or activity shall be performed in compliance with any conditions the Director of Planning and BuildingCommunity Development Director shall impose to alleviate potential disturbance to surrounding properties. (Ord. 092-1027U, 8-12-1992)
C. Sundays.

D. The following holidays:

New Year's Day
Presidents' Day
Memorial Day
Fourth of July
Labor Day
Veterans Day
Thanksgiving
The Friday after Thanksgiving
Christmas Eve
Christmas Day
New Year's Eve
If any of the above holidays fall on a Saturday, construction work and construction activity shall be prohibited on the preceding Friday. If any of the above holidays fall on a Sunday, construction work and construction activity shall be prohibited on the following Monday.

This section shall not apply to the emergency repairs necessary for health, safety or preservation of property. (Ord. 092-1015, 6-10-1992)

25.01.03: WORK BY OWNER PERMITTED:

The owner or occupant of property within the City may perform construction activity or construction work during the times described in section 25.01.02 of this article, provided that the property owner or occupant performs the work himself. (Ord. 092-1015, 6-10-1992)

25.01.04: PENALTY FOR VIOLATIONS:

Any person who violates or causes or permits any person to violate section 25.01.01 of this article shall be required, at the time of obtaining the permits required by this chapter, to pay a penalty equal to one hundred percent (100%) of the total amount of all permit fees assessed for the construction work or activity pursuant to this chapter in addition to the amount of the permit fees. (Ord. 092-1015, 6-10-1992; amd. Ord. 097-1107, 9-10-1997; Ord. 0-18-1335, 4-11-2018)

25.01.05: PROPERTY OWNER RESPONSIBLE:

The property owner or occupant of any property at which a violation of this chapter shall occur shall be responsible for and liable for charges provided for in section 25.01.04 of this article. (Ord. 092-1015, 6-10-1992; amd. Ord. 097-1107, 9-10-1997; Ord. 0-18-1335, 4-11-2018)

25.01.06: PROPERTY MAINTENANCE STANDARDS FOR CONSTRUCTION PROJECTS:

All projects, for which a valid building permit has been issued, with exception of interior remodels, shall be required to adhere to the following maintenance standards and no building or planning inspections shall be completed until all such applicable items are addressed:

A. One sign, visible from the street, must be posted, listing a contact name, company, and phone number. Said sign may be attached to a construction fence and must be six (6) square feet in area and no greater than thirty six inches (36") in length. No other signs shall be permitted in connection with the project.

B. Construction materials, equipment, storage bins, and portable facilities must be screened from public view.

C. Construction fencing must be installed on the site of any residential or commercial structure that is being, in whole or in part, demolished or reconstructed. Construction fencing must be installed in a manner that fully screens and secures the construction site. Construction fencing must include an opaque, dark-green screening material that is tightly secured to the fencing, free of holes and without advertising, except as allowed under subsection A of this section. The Director of Planning and BuildingCommunity Development Director, in his or her sole discretion, may require construction fencing on any other type of construction sites and may allow landscaping to substitute for some or all of the construction fencing. Construction fencing and any other approved screening material must be maintained in good condition.

D. A portable toilet shall be placed in the rear of the property with a minimum setback of ten feet (10') from side yard and rear yard property lines. If existing conditions prohibit access for the drop-off or the servicing of the portable toilet, the unit can be placed in the front yard provided the unit is placed no further than five feet (5') from the front of the house and ten feet (10') from any side property lines. The door opening shall not face either the street or an adjacent property and shall remain closed at all times. The portable toilet shall be screened from public view at all times.

No more than one toilet shall be used per property. The portable toilet shall be serviced a minimum of twice a week.

E. Roll-off containers shall be in good condition and appearance and emptied on a regular basis.

Containers shall be placed on private property unless an encroachment permit is obtained.

F. All construction equipment, storage bins and portable toilets shall be kept free of graffiti.

G. Construction materials, equipment, storage bins or debris shall not be placed on public property unless an encroachment permit has first been granted for such placement from Planning and Building and the Public Works Department. Conditions may be imposed to ensure appropriate safety signage, insurance and bonds.

H. Any dirt or debris tracked onto streets and sidewalks shall be removed immediately. All trash and litter on the job site shall be removed from public view on a daily basis.

I. Construction worker vehicles, equipment, and gate fencing shall not block public sidewalks.

J. Existing landscaping shall be maintained in good condition, including the City parkway area.

The property owner or contractor shall be responsible for mowing, trimming, weeding, and irrigating these areas as needed throughout the duration of the construction project.

K. A waste management form/plan shall be submitted at plan check and project final whenever the scope of work proposes a residential addition of one thousand (1,000) square feet or more; new construction of one thousand (1,000) square feet or more; a demolition project of one thousand (1,000) square feet or more, or tenant improvement projects of three thousand (3,000) square feet or more.

L. A tree protection plan shall be submitted at plan check where any construction activity takes place within the drip line of the canopy of any established tree or any tree in the City parkway. A separate cut sheet shall also be submitted identifying all established trees on the property. The tree protection plan must be prepared by either a registered consulting arborist or a certified arborist with the International Society of Arborists. Prior to any demolition or construction, a registered project arborist must provide the City with written certification of compliance with the tree protection plan. After any demolition or construction, a registered project arborist must provide the City a written inspection report regarding the effectiveness of the measures in the tree protection plan.

M. Sandbags, silt screens, or any similar methods are required to be installed on all projects during the rainy season (October - April) to prevent dirt, mud, and debris from flowing into the storm drain system. This shall be required only when the front yard landscaping is either removed or modified, regardless whether such removal or modification was intended as part of the construction project.

N. A Stormwater Pollution Prevention Plan (SWPPP) shall be submitted to the Planning and Building Department during the plan check process for all projects which disturb one or more acres of soil or whose projects disturb less than one acre but are part of a larger common plan of development that in total disturbs one or more acres. Projects include soil excavation, soil grading or other construction activities where soil may be displaced during weather events or landscape water run-off. (Ord. 0-18-1337, 10-10-2018)

25.01.07: EXPEDITED ELECTRIC VEHICLE CHARGING STATION PERMITTING:

A. Purpose: The purpose of this section is to provide for expedited processing of applications for electric vehicle charging stations in compliance with Government Code section 65850.7.

B. Definitions: The following definitions shall apply for purposes of this section:

ELECTRIC VEHICLE CHARGING STATION OR CHARGING STATION: Means any level of electric vehicle supply equipment station that is designed and built in compliance with article 625 of the California Electric Code, as it read on January 1, 2016, and delivers electricity from a source outside of an electric vehicle into a plug-in electric vehicle.

ELECTRONIC SUBMISSION: Means a submission of an application utilizing email, the internet, and/or facsimile transmission.

SPECIFIC, ADVERSE IMPACT: Means a significant, quantifiable, direct, and unavoidable impact, based on objective, identified, and written public health or safety standards, policies, or conditions as they existed on the date an application was deemed complete.

C. Expedited Review Process:

1. The building official shall adopt a checklist of all application requirements for expedited building permits for electric vehicle charging stations. The checklist shall substantially conform to the most current version of the "Plug-In Electric Vehicle Infrastructure Permitting Checklist" found in the "Zero-Emission Vehicles in California: Community Readiness Guidebook" published by the Governor's Office of Planning and Research. The checklist, application form, and any other documents required by the building official to process an application shall be published on the City's website.

2. Anyone seeking to install an electric vehicle charging station at any site within the City may apply to the building official for an expedited nondiscretionary building permit.

3. An application for an expedited building permit for an electric vehicle charging station and all associated documentation may be submitted to the building official in person, by mail, or by electronic submission. Electronic signatures may be used in lieu of wet signatures.

4. An application that, in the opinion of the building official, satisfies the information requirements of the checklist adopted by the City shall be deemed complete.

5. If an application for an expedited building permit is deemed incomplete, the building official shall provide a written correction notice of the deficiencies and the additional information required to complete the application.

6. If the building official determines that an application for an expedited building permit is complete, the building official shall process the application. If the building official determines that the proposed charging station meets all health and safety requirements of State and Federal law, and would not have a specific, adverse impact upon the public health or safety, the application shall be approved and a building permit shall be issued.

7. If the building official finds, based on substantial evidence, that a proposed charging station could have a specific, adverse impact upon the public health or safety, the applicant must apply for an electric vehicle charging station use permit in order to install the proposed charging station.

8. An application for an electric vehicle charging station use permit shall be reviewed by the building official. The building official shall not deny such an application without making written findings, based upon substantial evidence in the record, that the proposed charging station would have a specific, adverse impact upon the public health or safety which could not feasibly be satisfactorily mitigated or avoided. The written findings required for rejection of an electric vehicle charging station use permit application shall include the building official's basis for rejecting any potentially feasible alternatives that could mitigate or prevent the alleged adverse impact. Pursuant to Government Code section 65850.7, the building official's review shall be limited to health and safety issues. Aesthetic concerns, or other items not related to public health or safety shall not be considered.

9. A decision of the building official made pursuant to subsections C1 through C8 of this section may be appealed to the Planning Commission. The Planning Commission's review shall be subject to the same limitations as that of the building official, and only health and safety issues may be considered.

10. Any condition imposed on an application for an expedited building permit or electric vehicle charging station use permit shall be designed to mitigate the specific, adverse impact upon health and safety at the lowest possible cost.

D. No Requirement For Association Approval: Consistent with Government Code section 65850.7, the building official shall not condition the approval for any electric vehicle charging station permit on the approval of such a system by a homeowners association, as that term is defined by Civil Code section 4080. (Ord. 0-17-1329, 10-11-2017; amd. Ord. 0-18-1335, 4-11- 2018)

25.01.08: DEFINITIONS:

The following definitions shall apply to all structures that are regulated by this chapter. If in conflict with other provisions of this Code, these definitions shall control.

APPLICANT: Shall mean an owner or other responsible person who applies for a building or other permit under this chapter, or an extension thereof.

INCOMPLETE STRUCTURE: Shall mean a structure, or portion thereof, for which a building permit under article 2 of this chapter, or an extension thereof, has expired. "Incomplete structure" shall also include those structures for which issued permits under articles 3 through 6 and 12 of this chapter, and any extensions thereof, have expired.

JUSTIFIABLE CAUSE: As used in sections 105.5.1 and 105.5.4 of the Building Code, and sections R105.5.1 and R105.5.4 of the Residential Code, shall mean or refer to a delay in performance of work or installations under an active permit that is due to war, insurrection, floods, earthquakes, fires, casualties, epidemics, quarantine restrictions, unusually severe weather, strikes causing inability to secure necessary labor, materials or tools, acts of the City, or any other delays that are beyond the control and without the fault of the permit holder.

OWNER: Shall mean and include any person having legal title to, or who leases, rents, occupies or has charge, control or possession of, any real property in the City, including all persons shown as owners on the last equalized assessment roll of the Los Angeles County Assessor's Office.

Owners include persons with powers of attorney, executors of estates, trustees, or who are courtappointed administrators, conservators, guardians or receivers.

COMMUNITY DEVELOPMENT DIRECTOR AND/OR PLANNING AND BUILDING DIRECTOR: Shall mean the building official, or a designee thereof.

PROJECT: Shall mean an action or actions for which one or more permits are required by this chapter that concern a building or structure, or a portion thereof, with regard to construction, enlargement, alteration, repair, movement or demolition, and/or the erection, installation, enlargement, alteration, repair, removal, conversion or replacement of any electrical, fire- related, gas, mechanical or plumbing system, or portion thereof.

RESPONSIBLE PERSON: Shall mean any person, whether as an owner as defined in this section, or otherwise, who allows, causes, creates, maintains, suffers, or permits a public nuisance, or any violation of this chapter or other portion of this Code to exist or continue, by any act or the omission of any act or duty. A responsible person shall also include employees, principals, joint venturers, officers, agents, and/or other persons acting in concert with, or at the direction of, and/or with the knowledge and/or consent of the owner and/or occupant of the lot, building or structure on, or in which, a public nuisance or violation exists or existed. The actions or inactions of a responsible person's agent, employee, representative or contractor may be attributed to that responsible person.

STRUCTURE: Shall mean that which is built or constructed, an edifice, wall, fence, or building of any kind, or any piece of work artificially built up or composed of parts joined together in some definite manner.

SUCCESSFUL INSPECTION: Shall mean a required inspection (as set forth in section 110 of the Building Code or section 109 of the Residential Code) in which the work inspected was determined by the Planning and Building DirectorCommunity Development Director to meet all applicable minimum Building/Residential Code requirements and the inspection was approved and documented as successful. A successful inspection shall also mean approval of work inspected under an electrical, fire, plumbing or mechanical permit that meets all applicable minimum requirements of the Electrical, Fire, Plumbing or Mechanical Codes.

UNPERMITTED STRUCTURE: Shall mean any structure, or portion thereof, that was erected, constructed, enlarged, altered, repaired, moved, improved, removed, connected, converted, demolished or equipped with electrical, plumbing or mechanical installations, at any point in time, without the required approval(s) and permit(s) having first been obtained from the Planning and Building DirectorCommunity Development Director. Unpermitted structures shall include those structures for which an action that is regulated by the Fire Code has occurred without first obtaining the required permit. Unpermitted structures shall include an incomplete structure as defined in this section. (Ord. 0-18-1335, 4-11-2018)

25.01.09: LIMITATION ON AUTHORITY - BOARD OF APPEALS:

Notwithstanding any provision to the contrary in the most recent editions of the California Building, Electrical, Fire, Mechanical, Plumbing and Residential Codes (as adopted by the City), Boards of Appeal or similar reviewing authorities that are established by those codes shall not have the authority to consider determinations of the Planning and Building DirectorCommunity Development Director or other government officials, that a responsible person has violated this chapter. (Ord. 0-18-1335, 4-11-2018)

25.01.10: ADOPTION OF ADMINISTRATIVE REGULATIONS:

The chapters and article set forth below are hereby adopted by reference, subject to amendments thereto as set forth in this chapter. Those amendments shall control in the event of any conflict with adopted codes.

A. Chapter 1 of the 2016 California Building Code.

B. Chapter 1 of the 2016 California Residential Code.

C. Article 89 of the 2016 California Electrical Code.

D. Chapter 1 of the 2016 California Mechanical Code.

E. Chapter 1 of the 2016 California Plumbing Code.

F. Chapter 1 of the 2016 California Fire Code. (Ord. 0-18-1335, 4-11-2018) ARTICLE 02

BUILDING CODE
SECTION:

25.02.01: Building Code Adopted

25.02.02: Amendment Of Section 114.1

25.02.03: Amendment Of Section 113.1

25.02.04: Amendment Of Sections 109.2 And 109.6

25.02.05: Amendment Of Section 110.3.3.1, 110.3.9.1, 110.7

25.02.06: Amendment Of Section 111.1

25.02.07: Amendment Of Section 302.1

25.02.08: Amendment Of Section 312.2

25.02.09: Amendment Of Section 312.3 R317.1

25.02.10: Amendment Of Section 1505.1.1

25.02.11: Amendment Addition Of Section 1505.1.3

25.02.12: Amendment Of Section 1507.2.5.1

25.02.13: Amendment Of Section 1507.3.1

25.02.14: Amendment Of Section 1507.8.5

25.02.15: Amendment Of Section 1507.9.6

25.02.16: Amendment Addition Of Section 1613.51613.8

25.02.17: Amendment Addition Of Section 1613.61613.8

25.02.18: Amendment Addition Of Section 1613.71705.13.2

25.02.19: Amendment Addition Of Section 1613.8

25.02.20: Amendment Of Section 1705.3 And Table 1705.3

25.02.21: Amendment Of Section 1705.132

25.02.22: Amendment Addition Of Section 1710 And 1710.12304.10.4

25.02.23: Amendment Of Section 1807.1.4

25.02.24: Amendment Of Section 1807.1.6

25.02.25: Amendment Of Section 1809.3

25.02.26: Amendment Of Section 1809.7 And Table 1809.7

25.02.27: Amendment Of Section 1809.12

25.02.28: Amendment Of Section 1810.3.2.4

25.02.29: Amendment Of Section 1905.1.3

25.02.30: Amendment Of Section 1905.1.8

25.02.31: Amendment Of Section 1905.1 And Addition Of Sections 1905.1.9 And 1905.1.10

25.02.32: Amendment Of Section 2304.10.2

25.02.33: Amendment Of Section 2304.12.2.8

25.02.34: Amendment Of Section 2305.4

25.02.35: Amendment Of Section 2305.5

25.02.36: Amendment Of Section 2306.2

25.02.37: Amendment Of Section 2306.3 And Addition Of Section

25.02.38: Amendment Of Section 2308.3.2

25.02.39: Amendment Of Sections 2308.106.5 And 2308.6.5.1

25.02.40: Amendment Of Table 2308.6.12308.10.1

25.02.41: Amendment Of Section 2308.6.9

25.02.42: Amendment Of Section 3109.2.1

25.02.01: BUILDING CODE ADOPTED:

A. Code Adopted: The California Building Code, 20252 edition, based on the 20241 International Building Code as published by the International Code Council, including all appendices, is hereby adopted by reference, and together with certain amendments and deletions, shall constitute the Building Code of the City. A copy of said code shall be located in the Planning and Building Department and shall be, at all times, maintained for use and examination by the public.

B. Building Official Defined: For the purpose of this Code, the Planning and Building DirectorCommunity Development Director shall be the Building Official or his or her designee. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.02: AMENDMENT OF SECTION 114.1:

Notwithstanding the provisions of section 25.02.01 of this article, section 114.1 of the Building Code is amended to read as follows:
114.1 Unlawful acts. It shall be unlawful for any person, firm or corporation to erect, construct, enlarge, alter, repair, move, improve, remove, convert, demolish, equip, use, occupy, or maintain any building, structure or equipment or cause or permit the same to be done in violation of the Building Code.

It is hereby declared that any violation of the Building Code constitutes a public nuisance, and in addition to any other remedies provided by the Building Code for its enforcement, the City Council may bring civil suit to enjoin the violation of any provisions of this Building Code.

Any person, firm or corporation violating any of the provisions of the Building Code shall be deemed guilty of a misdemeanor and upon conviction thereof shall be punishable as provided in section 01.04.03A of this Code. Each separate day or any portion thereof during which violation of the Building Code occurs or continues shall be deemed to constitute a separate offense, and upon conviction thereof shall be punishable as herein provided. (Ord. 0-19-1357, 11-13-2019)

25.02.03: AMENDMENT OF SECTION 113.1:

Notwithstanding the provisions of section 25.02.01 of this article, section 113.1 of the Building Code is amended to read as follows:
113.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the Building Official relative to the application and interpretation of this Code, there shall be and is hereby created a Board of Appeals consisting of the members of the City Council. The Building Official shall be an ex officio member and shall act as Secretary to said Board but shall have no vote on any matter before the Board. The Board shall adopt rules of procedure for conducting its business, and shall render all decisions and findings, in writing, to the appellant with a duplicate copy to the Building Official. The Board may request the services of members of the community who are qualified by experience and training to interpret matters pertaining to the Building Code to act as technical assistants to the Board. Technical assistants shall have no vote on any matter before the Board.
(Ord. 0-19-1357, 11-13-2019)

25.02.04: AMENDMENT OF SECTIONS 109.2 AND 109.6:

Notwithstanding the provisions of section 25.02.01 of this article, sections 109.2 and 109.6 of the Building Code are amended to read as follows:
109.2 Schedule of permit fees. The fee for each permit shall be as periodically established by City Council resolution.
109.2.1 Plan review fees. When plans or other data are required pursuant Section 107.1, a plan review fee shall be paid at the time of submitting plans and specifications for review. Said plan review fee shall be 100 percent of the building permit fee established by resolution of the City Council.
109.2.2 Expiration of plan review. Applications for which no permit is issued within 180 days following the date the application or the date of final approval, if one exists, shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days on written request by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. No application shall be extended more than once. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee. 109.2.3 Expiration of building permits. Building permits will remain valid if the work on the site authorized by that permit is commenced within 12 months after its issuance, unless the permittee has abandoned the work authorized by the permit.

The Building Official may extend the permit expiration date for a period not exceeding 180 days on written request (submitted prior to the expiration date) by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. No application shall be extended more than once.

If an applicant wishes to renew a permit that has been expired for less than 6 months, 50% of the original fees paid shall be required to renew the permit. If an applicant wishes to renew a permit that has been expired for more than 6 months, 100% of the original fees paid shall be required to renew the permit.
109.6 Fee refunds. The Building Official may authorize refunding of any fee paid hereunder that was erroneously paid or collected.

The Building Official may authorize the refunding of not more than 80% of the permit fee paid when no work has been done under a permit in accordance with the Building code.

The Building Official shall not authorize refunding of any fee paid except on written application filed by the original permittee within 60 days of the date of fee payment. (Ord. 0-19-1357, 11-13-2019)

25.02.05: ADDITION OF SECTIONS 110.3.3.1, 110.3.9.1 AND 110.7:

Notwithstanding the provisions of section 25.02.01 of this article, new sections 110.3.3.1, 110.3.9.1, and 110.7 are added to the Building Code to read as follows:
110.3.3.1 Prior to frame approval, a rough zoning inspection is required in order to ensure compliance with the approved Development Plans.
110.3.9.1 Prior to final approval, a final zoning inspection is required in order to ensure final compliance with approved Development Plans.
110.7 Connections prohibited. Unless approval has been first obtained from the Building Official, the connection of gas or electrical utilities shall be prohibited until the final zoning, building, heating, air conditioning, electrical, plumbing and grading inspections, as required, are completed and approval has been granted on any building. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.06: AMENDMENT OF SECTION 111.1:

Notwithstanding the provisions of section 25.02.01 of this article, section 111.1 of the Building Code is amended to read as follows:
111.1 Use or Occupancy. No building or structure shall be used or occupied, and no change in the existing occupancy classification, tenancy, or change in proprietorship of a building or structure or portion thereof shall be made until the Building Official has issued a Certificate of Occupancy therefor as provided herein.

Exception: Group R, Division 3 and Group U occupancies.

Issuance of a Certificate of Occupancy shall not be construed as an approval of a violation of the provisions of the Building Code or of other ordinances of the City. Certificates presuming to give authority to violate or cancel the provisions of the Building Code or other ordinances of the City shall not be valid.
(Ord. 0-19-1357, 11-13-2019)

25.02.07: AMENDMENT OF SECTION 302.1:

Notwithstanding the provisions of section 25.02.01 of this article, section 302.1 of the Building Code is amended by adding a new paragraph to read as follows:

Any buildings or structures hereafter erected or constructed on C-l zoned property shall be constructed of one-hour fire resistive construction throughout.

This Section shall apply to:

1. Construction of any new building.

2. Addition, renovation or remodeling of any existing building when the value thereof is more than twenty percent (20%) of the estimated value of the existing building. The value of the proposed addition, renovation or remodeling shall be cumulative of all such renovation or remodeling over five (5) years.

The value of the proposed construction and of the existing building shall be determined by the Planning and Building Department based upon the latest edition of the Building Valuation Data as published by the International Code Council.
(Ord. 0-19-1357, 11-13-2019)

25.02.08: ADDITION OF SECTION 312.2:

Notwithstanding the provisions of section 25.02.01 of this article, section 312.2 is added to the Building Code to read as follows:
312.2 Garage access. To provide a secondary means of egress from a private garage, a door, minimum 2'6" x 6'8" dimensions, shall be provided in addition to the automobile access door or doors.
(Ord. 0-19-1357, 11-13-2019)

25.02.09: ADDITION AMENDMENT OF SECTION 312.3 R317.1:

Notwithstanding the provisions of section 25.02.01 of this article, section 312.3 317.1is added to the Building Code to read as follows:
312.3 Garage floor surfaces. In areas where motor vehicles are stored or operated, floor surface shall be concrete, and shall be a minimum 3-1/2 inches thick. No other floor coverings are permitted.

R317.1 Floor surface. Garage floor surfaces shall be of approved noncombustible material.

The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway. Combustible Finished Flooring shall be prohibited. (Underlined will be our amendment to the code). (Ord. 0-19-1357, 11-13-2019)

25.02.10: AMENDMENT OF SECTION 1505.1.1:

Notwithstanding the provisions of Section 25.02.01 of this Article, Section 1505.1.1 of the Building Code is amended by adding new paragraphs following the first sentence to read as follows:
1505.1.1 Roof CoveringsAssembly. Wood shakes and wood shingles for reroofing or repairs to an existing roof, or new construction of a roof are permitted provided they are Class A fire retardant roofing coverings.

Exception: Repairs to existing wood shake or wood shingle roof covering, which are considered minor (up to five percent (5%) of the roof area), may be allowed with Class B wood shingles or shakes.

Notwithstanding Section 1507.8.5, when more than thirty percent (30%) of the total roof area is replaced within any one (1) year period, the entire roof covering of every new structure and any roof covering applied in the alteration, repair or replacement of the roof of the existing structure shall be a fire-retardant roof covering that is at least Class A.

Reroofing over an existing Organic roof is not permitted unless the roofing is specifically approved in the classification required over existing substrate. Evidence of such approval must be submitted at the time of permit issuance. Fire severity zones are established by the Fire Department and the California Department of Forestry and Fire Protection. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-21-1380, 2-10-2021)

25.02.11: AMENDMENT ADDITION OF SECTION 1505.1.3:

Notwithstanding the provisions of section 25.02.01 of this article, section 1505.1.3 of the Building Code is amended by requiring minimum Class "BA" roofing for all types of construction for Group A-3, B, M and R-3 Occupancies.
(Ord. 0-19-1357, 11-13-2019)

25.02.12: ADDITION OF SECTION 1507.2.5.1:

Notwithstanding the provisions of section 25.02.01 of this article, section 1507.2.5.1 is added to the Building Code to read as follows:
1507.2.5.1 Not more than one overlay of asphalt shingles shall be applied over an existing asphalt or wood shingle roof. Asphalt shingles applied over wood shingles shall not have less than Type 30 nonperforated felt underlayment installed prior to reroofing. (Ord. 0-19-1357, 11-13-2019)

25.02.13: AMENDMENT OF SECTION 1507.3.1:

Notwithstanding the provisions of section 25.02.01 of this article, section 1507.3.1 of the Building Code is amended to read as follows:
1507.3.1 Deck requirements. Concrete and clay tile shall be installed only over solid structural sheathing boards.
(Ord. 0-19-1357, 11-13-2019)

25.02.14: AMENDMENT OF SECTION 1507.8.5:

Notwithstanding the provisions of Section 25.02.01 of this Article, Section 1507.8.5 of the Building Code is amended as follows:

Wood shingles shall be of naturally durable wood and comply with the requirements of Table 1507.8.5. If reroofing more than thirty percent (30%) of an existing roof within any one (1) year period, then the entire roof must comply with the current code. This means that all existing wood shingles must be removed and the new roof must be a code approved Class A roof covering as required by CBC Section 1505.1. If reroofing thirty percent (30%) or less of an existing roof within any one (1) year period, then only the area replaced needs to comply with the current code. This means that only the wood shingles in the area of replacement must be removed and the new roof material must be a code approved Class A roof covering as required by CBC Section 1505.1. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-21-1380, 2-10-2021)

25.02.15: AMENDMENT OF SECTION 1507.9.6:

Notwithstanding the provisions of Section 25.02.01 of this Article, Section 1507.9.6 of the Building Code is amended as follows:

Wood shake shall comply with the requirements of Table 1507.9.6. If reroofing more than thirty percent (30%) of an existing roof within any one (1) year period, then the entire roof must comply with the current code. This means that all existing wood shakes must be removed and the new roof must be a code approved Class A roof covering as required by CBC Section 1505.1.

If reroofing thirty percent (30%) or less of an existing roof within any one (1) year period, then only the area replaced needs to comply with current code. This means that only the wood shake in the area of replacement must be removed and the new roof material must be a code approved Class A roof covering as required by CBC Section 1505.1."
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-21-1380, 2-10-2021)

25.02.16: AMENDMENT ADDITION OF SECTION 1613.5 1613.8:

Notwithstanding the provisions of section 25.02.01 of this article, section 1613.5 is added to chapter 16 of the 2019 Edition of the California Building Code to read as follows:
1613.5 ASCE 7, 12.12.3 Modify ASCE 7 Equation 12.12-1 of Section 12.12.3 to read as follows:
(12 .12-1)
(Ord. 0-19-1357, 11-13-2019)

25.02.17: AMENDMENT ADDITION OF SECTION 1613.6 1613.8:

Notwithstanding the provisions of section 25.02.01 of this article, section 1613.6 1613.8 is added to chapter 16 of the 2019 Edition of the California Building Code to read as follows:
1613.6 1613.8 ASCE 7, 12.2.3.1, Exception 3. Modify ASCE 7 Section 12.2.3.1 Exception 3 to read as follows:

3. Detached one- and two-family dwellings up to two stories in height of light frame construction.
(Ord. 0-19-1357, 11-13-2019)

25.02.18: AMENDMENT ADDITION OF SECTION 1613.7 1705.13.2:

Notwithstanding the provisions of section 25.02.01 of this article, section 1613.7 is added to the Building Code to read as follows:
1613.7 1705.13.2 ASCE 7, Section 12.11.2.2.3. Modify ASCE 7, Section 12.11.2.2.3 to read as follows:

12.11.2.2.3 Wood Diaphragms. In wood diaphragms, the continuous ties shall be in addition to the diaphragm sheathing. Anchorage shall not be accomplished by use of toe nails or nails subject to withdrawal nor shall wood ledgers or framing be used in cross-grain bending or cross-grain tension. The diaphragm sheathing shall not be considered effective as providing ties or struts required by this section.

For structures assigned to Seismic Design Category D, E or F, wood diaphragms supporting concrete or masonry walls shall comply with the following:

1. The spacing of continuous ties shall not exceed 40 feet. Added chords of diaphragms may be used to form subdiaphragms to transmit the anchorage forces to the main continuous crossties.

2. The maximum diaphragm shear used to determine the depth of the subdiaphragm shall not exceed 75% of the maximum diaphragm shear.
(Ord. 0-19-1357, 11-13-2019)

25.02.19: ADDITIONAMENDMENT OF SECTION 1613.8:

Notwithstanding the provisions of section 25.02.01 of this article, section 1613.8 is added to the Building Code to read as follows:
1613.8 Suspended Ceilings. Minimum design and installation standards for suspended ceilings shall be determined in accordance with the requirements of Section 2506.2.1 of this Code and this section.
1613.8.1 Scope. This part contains special requirements for suspended ceilings and lighting systems. Provisions of Section 13.5.6 of ASCE 7-10 shall apply except as modified herein. 1613.8.2 General. The suspended ceilings and lighting systems shall be limited to 6 feet (1828 mm) below the structural deck unless the lateral bracing is designed by a licensed engineer or architect.
1613.8.3 Sprinkler Heads. All sprinkler heads (drops) except fire-resistance-rated floor/ceiling or roof/ceiling assemblies, shall be designed to allow for free movement of the sprinkler pipes with oversize rings, sleeves or adaptors through the ceiling tile. Sprinkler heads and other penetrations shall have a 2 in. (50mm) oversize ring, sleeve, or adapter through the ceiling tile to allow for free movement of at least 1 in. (25mm) in all horizontal directions. Alternatively, a swing joint that can accommodate 1 in. (25 mm) of ceiling movement in all horizontal directions is permitted to be provided at the top of the sprinkler head extension.

Sprinkler heads penetrating fire-resistance-rated floor/ceiling or roof/ceiling assemblies shall comply with Section 714 of this Code.
1613.8.4 Special Requirements for Means of Egress. Suspended ceiling assemblies located along means of egress serving an occupant load of 30 or more shall comply with the following provisions.
1613.8.4.1 General. Ceiling suspension systems shall be connected and braced with vertical hangers attached directly to the structural deck along the means of egress serving an occupant load of 30 or more and at lobbies accessory to Group A Occupancies. Spacing of vertical hangers shall not exceed 2 feet (610 mm) on center along the entire length of the suspended ceiling assembly located along the means of egress or at the lobby.
1613.8.4.2 Assembly Device. All lay-in panels shall be secured to the suspension ceiling assembly with two hold-down clips minimum for each tile within a 4-foot (1219 mm) radius of the exit lights and exit signs.
1613.8.4.3 Emergency Systems. Independent supports and braces shall be provided for light fixtures required for exit illumination. Power supply for exit illumination shall comply with the requirements of Section 1006.3 of this Code.
1613.8.4.4 Supports for Appendage. Separate support from the structural deck shall be provided for all appendages such as light fixtures, air diffusers, exit signs, and similar elements. (Ord. 0-19-1357, 11-13-2019)

25.02.20: AMENDMENT OF SECTIONS 1705.3 AND TABLE 1705.3:

Notwithstanding the provisions of section 25.02.01 of this article, section 1705.3 and table 1705.3 of the Building Code are amended to read as follows:
1705.3 Concrete Construction. The special inspections and verifications for concrete construction shall be as required by this section and Table 1705.3.

Exceptions: Special inspection shall not be required for:

Isolated spread concrete footings of buildings three stories or less above grade plane that are fully supported on earth or rock, where the structural design of the footing is based on a specified compressive strength, f c, no greater than 2,500 pounds per square inch (psi) (17.2 Mpa) regardless of the compressive strength specified in the construction documents or used in the footing construction.

2. Continuous concrete footings supporting walls of buildings three stories or less in height that are fully supported on earth or rock where:

2.1. The footings support walls of light-frame construction;

2.2. The footings are designed in accordance with Table 1805.4.2; or

2.3. The structural design of the footing is based on a specified compressive strength, f c, no greater than 2,500 pounds per square inch (psi) (17.2 Mpa), regardless of the compressive strength specified in the construction documents or used in the footing construction.

3. Nonstructural concrete slabs supported directly on the ground, including prestressed slabs on grade, where the effective prestress in the concrete is less than 150 psi (1.03 Mpa).

4. Concrete patios, driveways and sidewalks, on grade.

TABLE 1705.3

REQUIRED VERIFICATION AND INSPECTION OF CONCRETE CONSTRUCTION For SI: 1 inch = 25.4 mm.
a. Where applicable, see Section 1705.13.
b. Specific requirements for special inspection shall be included in the research report for the anchor issued by an approved source in accordance with 26.13 in ACI 318, or other qualification procedures. Where specific requirements are not provided, special instruction requirements shall be specified by the registered design professional and shall be approved by the building official prior to the commencement of the work. c. [OSHPD 1R, 2 & 5] Installation of all adhesive anchors in horizontal and upwardly inclined positions shall be performed by an ACI/CRSI Certified Adhesive Anchor Installer, except where the factored design tension on the anchor is less than 100 pounds and those anchors are clearly noted on the approved construction documents or where the anchors are shear dowels across cold joints in slabs on grade where the slab is not part of the lateral force-resisting system.
(Ord. 0-19-1357, 11-13-2019)

25.02.21: AMENDMENT OF SECTION 1705.123:

Notwithstanding the provisions of section 25.02.01 of this article, section 1705.13 of the Building Code is amended to read as follows:
1705.13 Special inspections for seismic resistance. Special inspections itemized in Sections 1705.13.1 through 1705.13.9, unless exempted by the exceptions of Section 1704.2, are required for the following:

1. The seismic force-resisting systems in structures assigned to Seismic Design Category C, D, E or F in accordance with Sections 1705.13.1.1 through 1705.13.1.2, as applicable.

2. Designated seismic systems in structures assigned to Seismic Design Category C, D, E or F in accordance with Section 1705.13.4.

3. Architectural, mechanical and electrical components in accordance with Sections 1705.13.5.

4. Storage racks in structures assigned to Seismic Design Category D, E or F in accordance with Section 1705.13.7.

5. Seismic isolation systems in accordance with Section 1705.13.8.

Exception: Special inspections itemized in Sections 1705.13.1 through 1705.13.9 are not required for structures designed and constructed in accordance with one of the following:

1. The structure consists of light-frame construction; the design spectral response acceleration at short periods, SDS, as determined in Section 1613.2.4, does not exceed 0.5; and the building height of the structure does not exceed 35 feet (10 668 mm).

2. The seismic force-resisting system of the structure consists of reinforced masonry or reinforced concrete; the design spectral response acceleration at short periods, SDS, as determined in Section 1613.2.4, does not exceed 0.5; and the building height of the structure does not exceed 25 feet (7620 mm).

3. The structure is a detached one- or two-family dwelling not exceeding two stories above grade plane, is not assigned to Seismic Design Category D, E or F and does not have any of the following horizontal or vertical irregularities in accordance with Section 12.3 of ASCE 7:

3.1 Torsional or extreme torsional irregularity.

3.2 Nonparallel systems irregularity.

3.3 Stiffness-soft story or stiffness-extreme soft story irregularity.

3.4 Discontinuity in lateral strength-weak story irregularity. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.22: ADDITION OF SECTIONS 1710 AND 1710.1 2304.10.4:

Notwithstanding the provisions of section 25.02.01 of this article, sections 1710 and 1710.1 2304.10.4 are added to, and chapter 35 of the Building Code is amended, to read as follows:
1710 General. The vertical load-bearing capacity, torsional moment capacity and deflection characteristics of joist hangers shall be determined in accordance with ASTM D 1761 and ASTM D 7147 as specified below using lumber having a specific gravity of 0.49 or greater, but not greater than 0.55, as determined in accordance with AF&PA AWC NDS for the joist and headers.

Exception: The joist length shall not be required to exceed 24 inches (610 mm). 1710.1 2304.10.4.1 Vertical load capacity for joist hangers. The vertical load-bearing capacity for the joist hanger shall be determined by testing a minimum of three joist hanger assemblies as specified in ASTM D 1761 or ASTM D 7147. If the ultimate vertical load for any one of the tests varies more than 20 percent from the average ultimate vertical load, at least three additional tests shall be conducted. The allowable vertical load-bearing of the joist hanger shall be the lowest value determined from the following:

1. The lowest ultimate vertical load for a single hanger from any test divided by three (where three tests are conducted and each ultimate vertical load does not vary more than 20 percent from the average ultimate vertical load).

2. The average ultimate vertical load for a single hanger from all tests divided by three (where six or more tests are conducted).

3. The average from all tests of the vertical loads that produce a vertical movement of the joist with respect to the header of 1/8 inch (3.2 mm).

4. The sum of the allowable design loads for nails or other fasteners utilized to secure the joist hanger to the wood members and allowable bearing loads that contribute to the capacity of the hanger.

5. The allowable design load for the wood members forming the connection.

Amend the Reference Standards in Chapter 35 for ASTM as follows:

(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.23: AMENDMENT OF SECTION 1807.1.4:

Notwithstanding the provisions of section 25.02.01 of this article, section 1807.1.4 of the Building Code is amended to read as follows:
1807.1.4 Permanent wood foundation systems. Permanent wood foundation systems shall be designed and installed in accordance with AF&PA PWF. Lumber and plywood shall be treated in accordance with AWPA Ul (Commodity Specification A, Use Category 4B and Section 5.2) and shall be identified in accordance with Section 2303.1.89.1. Permanent wood foundation systems shall not be used for structures assigned to Seismic Design Category D, E or F. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.24: AMENDMENT OF SECTION 1807.1.6:

Notwithstanding the provisions of section 25.02.01 of this article, section 1807.1.6 of the Building Code is amended to read as follows:
1807.1.6 Prescriptive design of concrete and masonry foundation walls. Concrete and masonry foundation walls that are laterally supported at the top and bottom shall be permitted to be designed and constructed in accordance with this section. Prescriptive design of foundation walls shall not be used for structures assigned to Seismic Design Category D, E or F. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.25: AMENDMENT OF SECTION 1809.3:

Notwithstanding the provisions of section 25.02.01 of this article, section 1809.3 of the Building Code is amended to read as follows:
1809.3 Stepped footings. The top surface of footings shall be level. The bottom surface of footings shall be permitted to have a slope not exceeding one unit vertical in 10 units horizontal (10-percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the surface of the ground slopes more than one unit vertical in 10 units horizontal (10-percent slope).

For structures assigned to Seismic Design Category D, E or F, the stepping requirement shall also apply to the top surface of grade beams supporting walls. Footings shall be reinforced with four No. 4 rebar. Two bars shall be place at the top and bottom of the footings as shown in Figure 1809.3.

FIGURE 1809.3

STEPPED FOOTING
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.26: AMENDMENT OF SECTION 1809.7 AND TABLE 1809.7:

Notwithstanding the provisions of section 25.02.01 of this article, section 1809.7 and table 1809.7 of the Building Code are amended to read as follows:
1809.7 Prescriptive footings for light-frame construction. Where a specific design is not provided, concrete or masonry-unit footings supporting walls of light-frame construction shall be permitted to be designed in accordance with Table 1809.7. Prescriptive footings in Table 1809.7 shall not exceed one story above grade plane for structures assigned to Seismic Design Category D, E or F.

TABLE 1809.7

PRESCRIPTIVE FOOTINGS SUPPORTING WALLS OF LIGHT-FRAME
CONSTRUCTION a, b, c, d, e
For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm
a. Depth of footings shall be in accordance with Section 1809.4. b. The ground under the floor shall be permitted to be excavated to the elevation of the top of the footing.
c. Not Adopted.
d. See Section 1908 for additional requirements for concrete footings of structures assigned to Seismic Design Category C, D, E or F.
e. For thickness of foundation walls, see Section 1807.1.6. f. Footings shall be permitted to support a roof addition to the stipulated number of floors.

Footings supporting roof only shall be as required for supporting one floor. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.27: AMENDMENT OF SECTION 1809.12:

Notwithstanding the provisions of section 25.02.01 of this article, section 1809.12 of the Building Code is amended to read as follows:
1809.12 Timber footings. Timber footings shall be permitted for buildings of Type V construction and as otherwise approved by the building official. Such footings shall be treated in accordance with AWPA Ul (Commodity Specification A, Use Category 4B). Treated timbers are not required where placed entirely below permanent water level, or where used as capping for wood piles that project above the water level over submerged or marsh lands. The compressive stresses perpendicular to grain in untreated timber footing supported upon treated piles shall not exceed 70 percent of the allowable stresses for the species and grade of timber as specified in the AF&PA NDS. Timber footings shall not be used in structures assigned to Seismic Design Category D, E or F.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.28: AMENDMENT OF SECTION 1810.3.2.4:

Notwithstanding the provisions of section 25.02.01 of this article, section 1810.3.2.4 of the Building Code is amended to read as follows:
1810.3.2.4 Timber. Timber deep foundation elements shall be designed as piles or poles in accordance with AF&PA NDS. Round timber elements shall conform to ASTM D 25. Sawn timber elements shall conform to DOC PS-20. Timber shall not be used in structures assigned to Seismic Design Category D, E or F.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.29: AMENDMENT OF SECTION 1905.1.3
Notwithstanding the provisions of section 25.02.01 of this article, section 1905.1.3 of the Building Code is amended to read as follows:
1905.1.3 ACI 318, Section 18.5. Modify ACI 318, Section 18.5, by renumbering Section 18.5.2.2 to become new Sections 18.5.2.2, 18.5.2.3, 18.5.2.4 and 18.5.2.5 to read as follows:

18.5.2.2 - Connections that are designed to yield shall be capable of maintaining 80 percent of their design strength at the deformation induced by the design displacement or shall use Type 2 mechanical splices.

18.5.2.3 - Elements of the connection that are not designed to yield shall develop at least 1.5 Sy.

18.5.2.4 - In structures assigned to Seismic Design Category D, E or F, intermediate precast wall panels and wall piers shall be designed in accordance with Section 21.9 or 21.13.

18.5.2.5 - Wall piers not designed as part of a moment frame in buildings assigned to Seismic Design Category C shall have transverse reinforcement designed to resist the shear forces determined from 21.3.3. Spacing of transverse reinforcement shall not exceed 8 inches (203 mm).

Transverse reinforcement shall be extended beyond the pier clear height for at least 12 inches (305 mm).

Exceptions:

1. Wall piers that satisfy 18.10.8 or 18.14.

2. Wall piers along a wall line within a story where other shear wall segments provide lateral support to the wall piers and such segments have a total stiffness of at least six times the sum of the stiffnesses of all the wall piers.

18.5.2.6 - Wall segments with a horizontal length-to-thickness ratio less than 2.5 shall be designed as columns.
(Ord. 0-19-1357, 11-13-2019)

25.02.30: AMENDMENT OF SECTION 1905.1.8:

Notwithstanding the provisions of section 25.02.01 of this article, section 1905.1.7 of the Building Code is amended to read as follows:
1905.1.7 ACI 318, Section 14.1.4. Delete ACI 318, Section 14.1.4, and replace with the following:

14.1.1 - Plain concrete in structures assigned to Seismic Design Category C, D, E or F.

14.1.4.1 - Structures assigned to Seismic Design Category C, D, E or F shall not have elements of structural plain concrete, except as follows:
(a) Concrete used for fill with a minimum cement content of two (2) sacks of Portland cement or cementious material per cubic yard.
(b) Isolated footings of plain concrete supporting pedestals or columns are permitted, provided the projection of the footing beyond the face of the supported member does not exceed the footing thickness.
(c) Plain concrete footings supporting walls are permitted provided the footings have at least two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall have a total area of not less than 0.002 times the gross cross-sectional area of the footing. A minimum of one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement shall be provided at corners and intersections.

In detached one- and two-family dwellings three stories or less in height and constructed with stud-bearing walls, are permitted to have plain concrete footings with at least two continuous longitudinal reinforcing bars not smaller than No. 4 are permitted to have a total area of less than

0.002 times the gross cross-sectional area of the footing. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.31: AMENDMENT OF SECTION 1905.1 AND ADDITION OF SECTIONS 1905.1.9 AND 1905.1.10:

Notwithstanding the provisions of section 25.02.01 of this article, section 1905.1 is amended and sections 1905.1.9 and 1905.1.10 are added to the Building Code to read as follows:
1905.1 General. The text of ACI 318 shall be modified as indicated in Sections 1905.1 through 1905.1.8
1905.1.9 ACI 318, Section 21.6.4. Modify ACI 318, Section 21.6.4, by adding Section 21.6.4.8 and 12.6.4.9 as follows:

21.6.4.8 Where the calculated point of contraflexure is not within the middle half of the member clear height, provide transverse reinforcement as specified in ACI 318 Sections 21.6.4.1, Items (a) through (c), over the full height of the member.

21.6.4.9 - At any section where the design strength, Pn, of the column is less than the sum of the shears Ve computed in accordance with ACI 318 Sections 21.5.4.1 and 21.6.5.1 for all the beams framing into the column above the level under consideration, transverse reinforcement as specified in ACI 318 Sections 21.6.4.1 through 21.6.4.3 shall be provided. For beams framing into opposite sides of the column, the moment components are permitted to be assumed to be of opposite sign. For the determination of the design strength, Pn, of the column, these moments are permitted to be assumed to result from the deformation of the frame in any one principal axis. 1905.1.10 ACI 318, Section 21.9.4. Modify ACI 318, Section 21.9.4, by adding Section 21.9.4.6 as follows:

21.9.4.6 - Walls and portions of walls with Pu > 0.35Po shall not be considered to contribute to the calculated shear strength of the structure for resisting earthquake-induced forces. Such walls shall conform to the requirements of ACI 318 Section 21.13. (Ord. 0-19-1357, 11-13-2019)

25.02.32: AMENDMENT OF SECTION 2304.10.2:

Notwithstanding the provisions of section 25.02.01 of this article, section 2304.10.1 of the Building Code is amended to read as follows:
2304.10.2 Fastener requirements. Connections for wood members shall be designed in accordance with the appropriate methodology in Section 2302.1. The number and size of fasteners connecting wood members shall not be less than that set forth in Table 2304.10.2. Staple fasteners in Table 2304.10.2 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.

Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.33: AMENDMENT OF SECTION 2304.12.2.8:

Notwithstanding the provisions of section 25.02.01 of this article, section 2304.12.5 of the Building Code is amended to read as follows:
2304.12.2.8 Wood used in retaining walls and cribs. Wood installed in retaining or crib walls shall be preservative treated in accordance with AWPA Ul (Commodity Specifications A or F) for soil and fresh water use. Wood shall not be used in retaining or crib walls for structures assigned to Seismic Design Category D, E or F.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.34: ADDITION OF SECTION 2305.4:

Notwithstanding the provisions of section 25.02.01 of this article, section 2305.4 is added to the Building Code to read as follows:
2305.4 Quality of Nails. I23n Seismic Design Category D, E or F, mechanically driven nails used in wood structural panel shear walls shall meet the same dimensions as that required for handdriven nails, including diameter, minimum length and minimum head diameter. Clipped head or box nails are not permitted in new construction. The allowable design value for clipped head nails in existing construction may be taken at no more than the nail-head-area ratio of that of the same size hand-driven nails.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.35: ADDITION OF SECTION 2305.5:

Notwithstanding the provisions of section 25.02.01 of this article, section 2305.5 is added to the Building Code to read as follows:
2305.5 Hold-down connectors. In Seismic Design Category D, E or F, hold-down connectors shall be designed to resist shear wall overturning moments using approved cyclic load values or 75 percent of the allowable seismic load values that do not consider cyclic loading of the product.

Connector bolts into wood framing shall require steel plate washers on the post on the opposite side of the anchorage device. Plate size shall be a minimum of 0.229 inch by 3 inches by 3 inches (5.82 mm by 76 mm by 76 mm) in size. Hold-down connectors shall be tightened to finger tight plus one half (1/2) wrench turn just prior to covering the wall framing. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.36: AMENDMENT OF SECTION 2306.2:

Notwithstanding the provisions of section 25.02.01 of this article, section 2306.2 of the Building Code is amended to read as follows:
2306.2 Wood-frame diaphragms. Wood-frame diaphragms shall be designed and constructed in accordance with AWCF&PA SDPWS. Where panels are fastened to framing members with staples, requirements and limitations of AF&PA SDPWS shall be met and the allowable shear values set forth in Table 2306.2(1) or 2306.2(2) shall only be permitted for structures assigned to Seismic Design Category A, B, or C.

Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official.

The allowable shear values in Tables 2306.2(1) and 2306.2(2) are permitted to be increased 40 percent for wind design.

Exception: [DSA-SS, DSA-SS/CC and OSHPD 1, 2 &4] Wood structural panel diaphragms using staples as fasteners are not permitted by DSA and OSHPD.

Wood structural panel diaphragms used to resist seismic forces in structures assigned to Seismic Design Category D, E or F shall be applied directly to the framing members.

Exception: Wood structural panel diaphragms are permitted to be fastened over solid lumber planking or laminated decking, provided the panel joints and lumber planking or laminated decking joints do not coincide.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.37: AMENDMENT OF SECTION 2306.3 AND ADDITION OF SECTION 2307.2:

Notwithstanding the provisions of section 25.02.01 of this article, section 2306.3 is amended and section 2307.2 is added to the Building Code to read as follows:
2306.3 Wood-frame shear walls. Wood-frame shear walls shall be designed and constructed in accordance with AF&PA AWC SDPWS. For structures assigned to Seismic Design Category D, E, or F, application of Tables 4.3A and 4.3B of AF&PA SDPWS shall include the following:

1. Wood structural panel thickness for shear walls shall not be less than 3/8 inch thick and studs shall not be spaced at more than 16 inches on center.

2. The maximum nominal unit shear capacities for 3/8 inch wood structural panels resisting seismic forces in structures assigned to Seismic Design Category D, E or F is 400 pounds per linear foot (plf).

Exception: Other nominal unit shear capacities may be permitted if such values are substantiated by cyclic testing and approved by the building official.

3. Where shear design values using allow stress design (ASD) exceed 350 plf or load and resistance factor design (LRFD) exceed 500 plf, all framing members receiving edge nailing from abutting panels shall not be less than a single 3-inch nominal member, or two 2-inch nominal members fastened together in accordance with Section 2306.1 to transfer the design shear value between framing members. Wood structural panel joint and sill plate nailing shall be staggered at all panel edges. See Section 4.3.6.1 and 4.3.6.4.3 of AF&PA SDPWS for sill plate size and anchorage requirements.

4. Nails shall be placed not less than 1/2 inch in from the panel edges and not less than 3/8 inch from the edge of the connecting members for shear greater than 350 plf using ASD or 500 plf using LRFD. Nails shall be placed not less than 3/8 inch from panel edges and not less than 1/4 inch from the edge of the connecting members for shears of 350 plf or less using ASD or 500 plf or less using LRFD.

5. Table 4.3B application is not allowed for structures assigned to Seismic Design Category D, E, or F.

For structures assigned to Seismic Design Category D, application of Table 4.3C of AF&PA SDPWS shall not be used below the top level in a multi-level building for structures.

Where panels are fastened to framing members with staples, requirements and limitations of AF&PA SDPWS shall be met and the allowable shear values set forth in Table 2306.3(1), 2306.3(2) or 2306.3(3) shall only be permitted for structures assigned to Seismic Design Category A, B, or C.

Exception: Allowable shear values where panels are fastened to framing members with staples may be used if such values are substantiated by cyclic testing and approved by the building official.

The allowable shear values in Tables 2306.3(1) and 2306.3(2) are permitted to be increased 40 percent for wind design. Panels complying with ANSI/APA PRP-210 shall be permitted to use design values for Plywood Siding in the AF&PA SDPWS.

Exception: [DSA-SS 7DSA-SS/CC and OSHPD 1, 2 &4] Wood structural panel shear walls using staples as fasteners are not permitted by DSA and OSHPD. 23067.32 Wood-frame shear walls. Wood-frame shear walls shall be designed and constructed in accordance with Section 2306.3 as applicable.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.38: ADDITION OF SECTION 2308.3.2:

Notwithstanding the provisions of Section 25.02.01 of this Article, Section 2308.3.2 is added to the Building Code to read as follows:
2308.3.2 Braced wall line support. Braced wall lines shall be supported by continuous foundations.

Exception: For structures with a maximum plan dimension not over 50 feet (15240 mm), continuous foundations are required at exterior walls only for structures assigned to Seismic Design Category A, B, or C.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.39: AMENDMENT OF SECTIONS 2308.106.5 AND 2308.6.5.1:

Notwithstanding the provisions of section 25.02.01 of this article, sections 2308.6.5 and 2308.6.5.1, of the Building Code are amended to read as follows:
2308.6.5 Alternative bracing. Any bracing required by Section 2308.6.5 is permitted to be replaced by the following:

1. In one-story buildings, each panel shall have a length of not less than 2 feet 8 inches (813 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with 3/8-inch-minimum-thickness (9.5 mm) wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Table 2304.10.1 and blocked at wood structural panel edges. For structures assigned to Seismic Design Category D or E, each panel shall be sheathed on one face with 15/32-inch-minimum-thickness (11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports. Two anchor bolts installed in accordance with Section 2308.3.1 shall be provided in each panel. Anchor bolts shall be placed at each panel outside quarter points. Each panel end stud shall have a tie-down device fastened to the foundation, capable of providing an approved uplift capacity of not less than 1,800 pounds (8006 N). The tie-down device shall be installed in accordance with the manufacturer's recommendations. The panels shall be supported directly on a foundation or on floor framing supported directly on a foundation that is continuous across the entire length of the braced wall line. This foundation shall be reinforced with not less than one No. 4 bar top and bottom.

Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12-inch by 12-inch (305 mm by 305 mm) continuous footing or turned down slab edge is permitted at door openings in the braced wall line. This continuous footing or turned down slab edge shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped 15 inches (381 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line.

2. In the first story of two-story buildings, each wall panel shall be braced in accordance with Section 2308.6.5.1, Item 1, except that the wood
structural panel sheathing shall be provided on both faces, three anchor bolts shall be placed at one-quarter points, and tie-down device uplift capacity shall not be less than 3,000 pounds (13 344 N).
2308.610.5.1 Alternate bracing wall panel adjacent to a door or window opening. Any bracing required by Section 2308.6.5 is permitted to be replaced by the following when used adjacent to a door or window opening with a full-length header:

1. In one-story buildings, each panel shall have a length of not less than 16 inches (406 mm) and a height of not more than 10 feet (3048 mm). Each panel shall be sheathed on one face with a single layer of 3/8 inch (9.5 mm) minimum thickness wood structural panel sheathing nailed with 8d common or galvanized box nails in accordance with Figure 2308.6.1. For structures assigned to Seismic Design Category D or E, each panel shall be sheathed on one face with 15/32-inchminimum-thickness (11.9 mm) wood structural panel sheathing nailed with 8d common nails spaced 3 inches on panel edges, 3 inches at intermediate supports and in accordance with Figure 2308.9.3.2. The wood structural panel sheathing shall extend up over the solid sawn or gluedlaminated header and shall be nailed in accordance with Figure 2308.8.3.1. A built-up header consisting of at least two 2 x 12s and fastened in accordance with Item 24 of Table 2304.9.1 shall be permitted to be used. A spacer, if used, shall be placed on the side of the built-up beam opposite the wood structural panel sheathing. The header shall extend between the inside faces of the first full-length outer studs of each panel. The clear span of the header between the inner studs of each panel shall be not less than 6 feet (1829 mm) and not more than 18 feet (5486 mm) in length. A strap with an uplift capacity of not less than 1,000 pounds (4,400 N) shall fasten the header to the inner studs opposite the sheathing. One anchor bolt not less than 5/8 inch (15.9 mm) diameter and installed in accordance with Section 2308.6 shall be provided in the center of each sill plate. The studs at each end of the panel shall have a tie-down device fastened to the foundation with an uplift capacity of not less than 4,200 pounds (18 480 N).

Where a panel is located on one side of the opening, the header shall extend between the inside face of the first full-length stud of the panel and the bearing studs at the other end of the opening.

A strap with an uplift capacity of not less than 1,000 pounds (4400 N) shall fasten the header to the bearing studs. The bearing studs shall also have a tie-down device fastened to the foundation with an uplift capacity of not less than 1,000 pounds (4400 N).

The tie-down devices shall be an embedded strap type, installed in accordance with the manufacturer's recommendations. The panels shall be supported directly on a foundation that is continuous across the entire length of the braced wall line. This foundation shall be reinforced with not less than one No. 4 bar top and bottom.

Where the continuous foundation is required to have a depth greater than 12 inches (305 mm), a minimum 12-inch by 12-inch (305 mm by 305 mm) continuous footing or turned down slab edge is permitted at door openings in the braced wall line. This continuous footing or turned down slab edge shall be reinforced with not less than one No. 4 bar top and bottom. This reinforcement shall be lapped not less than 15 inches (381 mm) with the reinforcement required in the continuous foundation located directly under the braced wall line.

2. In the first story of two-story buildings, each wall panel shall be braced in accordance with Item 1 above, except that each panel shall have a length of not less than 24 inches (610 mm). (Ord. 0-19-1357, 11-13-2019)

25.02.40: AMENDMENT OF TABLE 2308.6.1 2308.10.1:

Notwithstanding the provisions of section 25.02.01 of this article, table 2308.6.1 of the Building Code is amended to read as follows:

TABLE 2308.6.1 2308.10.1

WALL BRACING IN SEISMIC DESIGN CATEGORIES D AND E
(Minimum Percentage of Wall Bracing per each Braced Wall Linea) For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm.
a. Minimum length of panel bracing of one face of the wall for S-W sheathing shall be at least 4'-0" long or both faces of the wall for G-P sheathing shall be at least 8'-0" long; h/w ratio shall not exceed 2:1. For S-W panel bracing of the same material on two faces of the wall, the minimum length is permitted to be one-half the tabulated value but the h/w ratio shall not exceed 2:1 and design for uplift is required. The 2:1 h/w ratio limitation does not apply to alternate braced wall panels constructed in accordance with Section 2308.9.3.1 or 2308.9.3.2 2308.10.2. Wall framing to which sheathing used for bracing is applied shall be nominal 2 inch wide [actual 11/2 inch (38 mm)] or larger members and spaced a maximum of 16 inches on center. Braced wall panel construction types shall not be mixed within a braced wall line. b. G-P = gypsum board, portland cement plaster or gypsum sheathing boards; S-W = wood structural panels;
c. Nailing as specified below shall occur at all pane! edges at studs, at top and bottom plates and, where occurring, at blocking:

For 1/2-inch gypsum board, 5d (0.113 inch diameter) cooler nails at 7 inches on center; For 5/8- inch gypsum board, No. 11 gage (0.120 inch diameter) cooler nails at 7 inches on center; For gypsum sheathing board, 1-3/4 inches long by 7/16-inch head, diamond point galvanized nails at 4 inches on center;
For gypsum lath, No. 13 gage (0.092 inch) by 1-1/8 inches long, 19/64-inch head, plasterboard at 5 inches on center;
For Portland cement plaster, No. 11 gage (0.120 inch) by 11/2 inches long, 7/16- inch head at 6 inches on center;
d. S-W sheathing shall be a minimum of 15/32" thick nailed with 8d common placed 3/8 inches from panel edges and spaced not more than 6 inches on center and 12 inches on center along intermediate framing members.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.41: AMENDMENT OF SECTION 2308.6.9:

Notwithstanding the provisions of section 25.02.01 of this article, section 2308.6.9 of the Building Code is amended to read as follows:
2308.106.9 Attachment of sheathing. Fastening of braced wall panel sheathing shall not be less than that prescribed in Table 2308.6.1 and 2304.10.1. Wall sheathing shall not be attached to framing members by adhesives. Staple fasteners in Table 2304.10.1 shall not be used to resist or transfer seismic forces in structures assigned to Seismic Design Category D, E or F.

Exception: Staples may be used to resist or transfer seismic forces when the allowable shear values are substantiated by cyclic testing and approved by the building official.

All braced wall panels shall extend to the roof sheathing and shall be attached to parallel roof rafters or blocking above with framing clips (18 gauge minimum) spaced at maximum 24 inches (6096 mm) on center with four 8d nails per leg (total eight 8d nails per clip). Braced wall panels shall be laterally braced at each top corner and at maximum 24 inches (6096 mm) intervals along the top plate of discontinuous vertical framing.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.02.42: ADDITION OF SECTION 3109.2.1:

Notwithstanding the provisions of section 25.02.01 of this article, section 3109.2.1 is added to the Building Code to read as follows:
31109.2.1 Driveway Gates. Driveway gates serving as part of the required pool barrier shall comply with the following:

1. Driveway gates, if operated manually, shall have a spring-loaded, self-closing, self-latching mechanism installed in accordance with the same procedure required in the City Building Code for pedestrian gates.

2. Driveway gates may be equipped with an electric gate-operating device provided that it is approved by a recognized Electrical Testing Agency and contain a battery backup system.

3. Electric gate-operating devices shall be provided with a safety mechanism to interrupt and recycle the device, should the gate become blocked.

4. Electric gate-operating devices shall be provided with a time delay closing device, which is set and maintained to activate a maximum of 30 seconds after the gate has been opened. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023) Section 3. New Article 03 Residential Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 03

RESIDENTIAL CODE
SECTION:

25.03.01: Residential Code Adopted

25.03.02: Amendment Of Section R112.1

25.03.03: Addition Of Section R113.1

25.03.04: Amendment Of Sections R108.2 And R108.5

25.03.05: Addition of Sections R109.1.5.4, R109.1.5.5, And R109.1.6.3

25.03.06: Amendment Of Table R301.2.2.1.1 And Section R301.2.2.1.2

25.03.07: Amendment Of Section R301.2.2.6

25.03.08: Addition of Section R301.2.2.11

25.03.09: Addition of Section R337.1

25.03.0910: Amendment Of Section R401.1

25.03.101: Amendment Of Sections R403.1.2, R403.1.3 And R403.1.5

25.03.112: Amendment Of Section R404.2

25.03.123: Amendment Of Section R501.1

25.03.134: Amendment Of Section R503.2.4

25.03.145: Amendment Of Table R602.3(1)

25.03.156: Amendment Of Table R602.3(2)

25.03.167: Amendment Of Table R602.10.3(3)

25.03.178: Amendment Of Table R602.10.4

25.03.189: Amendment Of Figure R602.10.6.1

25.03.2019: Amendment Of Figure R602.10.6.2

25.03.201: Amendment Of Table R602.10.5

25.03.212: Amendment Of Section R602.10.2.3

25.03.223: Amendment Of Section R606.4.4

25.03.234: Amendment Of Section R606.12.2.2.3

25.03.245: Amendment Of Section R602.3.2

25.03.256: Amendment Of Section R803.2.4

25.03.267: Amendment Of Section R1001.3.1

25.03.01: RESIDENTIAL CODE ADOPTED:

Except as hereinafter provided, the California Residential Code, 20252 edition, based on the 20241 International Residential Code as published by the International Code Council, including all appendices, is hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the Residential Code of the City. A copy of such code shall be located in the Planning and Building Department and shall be, at all times, maintained for use and examination by the public. For the purposes of this code, the Building Official shall be the Building Official. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.03.02: AMENDMENT OF SECTION R112.1:

Notwithstanding the provisions of section 25.03.01 of this article, section R112 of the Residential Code is hereby amended to read as follows:

R112.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the Building Official relative to the application and interpretation of the Residential Code, there shall be and is hereby created a Board of Appeals consisting of the members of the City Council.

The Building Official shall be an ex officio member of and shall act as Secretary to said Board but shall have no vote on any matter before the Board. The Board shall adopt rules of procedures for conducting its business, and shall render all decisions and findings in writing to the appellant with a duplicate copy to the Building Official. The Board may request the services of members of the community who are qualified by experience and training to interpret matters pertaining to the Residential Code to act as technical assistants to the Board. Technical assistants shall have no vote on any matter before the Board.
(Ord. 0-19-1357, 11-13-2019)

25.03.03: AMENDMENT OF SECTION R113.1:

Notwithstanding the provisions of section 25.03.01 of this article, section R113.1 of the Residential Code is amended to read as follows:

R113.1 Unlawful acts. It shall be unlawful for any person, firm or corporation to erect, construct, enlarge, alter, repair, move, improve, remove, convert, demolish, equip, use, occupy, or maintain any building, structure or equipment or cause or permit the same to be done in violation of the Residential Code.

It is hereby declared that any violation of the Residential Code constitutes a public nuisance, and in addition to any other remedies provided by the Residential Code for its enforcement, the City Council may bring civil suit to enjoin the violation of any provisions of this Residential Code.

Any person, firm or corporation violating any of the provisions of the Residential Code shall be deemed guilty of a misdemeanor and upon conviction thereof shall be punishable as provided in section 01.04.03A of this Code. Each separate day or any portion thereof during which violation of the Residential Code occurs or continues shall be deemed to constitute a separate offense, and upon conviction thereof shall be punishable as herein provided. (Ord. 0-19-1357, 11-13-2019)

25.03.04: AMENDMENT OF SECTIONS RIl08.2 AND R108.5:

Notwithstanding the provisions of section 25.03.01 of this article, sections R108.2 and R108.5 of the Residential Code are amended to read as follows:

R108.2 Schedule of permit fees. The fee for each permit shall be as periodically established by City Council resolution.

R108.2.1 Plan review fees. When plans or other data are required pursuant to Section R106, a plan review fee shall be paid at the time of submitting plans and specifications for review. Said plan review fee shall be one-hundred percent (100%) of the building permit fee established by resolution of the City Council.

R108.2.2 Expiration of plan review. Applications for which no permit is issued within 180 days following the date the application or the date of final approval, if one exists, shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days on written request by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. No application shall be extended more than once. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee.

R108.2.3 Expiration of building permits. Building permits will remain valid if the work on the site authorized by that permit is commenced within 12 months after its issuance, unless the permittee has abandoned the work authorized by the permit.

The Building Official may extend the permit expiration date for a period not exceeding 180 days on written request (submitted prior to the expiration date) by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. No application shall be extended more than once.

If an applicant wishes to renew a permit that has been expired for less than 6 months, 50% of the original fees paid shall be required to renew the permit. If an applicant wishes to renew a permit that has been expired for more than 6 months, 100% of the original fees paid shall be required to renew the permit.

R108.5 Fee refunds. The Building Official may authorize refunding of any fee paid hereunder that was erroneously paid or collected.

The Building Official may authorize the refunding of not more than 80% of the permit fee paid when no work has been done under a permit in accordance with the Residential Code.

The Building Official shall not authorize refunding of any fee paid except on written application filed by the original permittee within 60 days of the date of fee payment. (Ord. 0-19-1357, 11-13-2019)

25.03.05: ADDITION OF SECTIONS Rl09.1.5.4, RIl09.1.5.5, and R109.1.6.3:

Notwithstanding the provisions of section 25.03.01 of this article, new sections R109.1.5.3, R109.1.5.3, and R109.1.6.3 are added to the Residential Code to read as follows:

R109.1.5.4 Prior to frame approval, a rough zoning inspection is required in order to ensure compliance with the approved Development Plans.

R109.1.5.5 Prior to final approval, a final zoning inspection by Planning Department staff is required in order to ensure final compliance with approved Development Plans.

R109.1.6.3 Connections prohibited. Unless approval has been first obtained from the Building Official, the connection of gas or electrical utilities shall be prohibited until the final building, heating, air conditioning, electrical, plumbing and grading inspections, as required, are completed and approval has been granted on any building.
(Ord. 0-19-1357, 11-13-2019)

25.03.06: AMENDMENT OF TABLE R301.2.2.1.1 AND SECTION R301.2.2.1.2:

Notwithstanding the provisions of section 25.03.01 of this article, table R301.2.2.1.1 and section R301.2.2.1.2 of the Residential Code are amended to read as follows:

TABLE R301.2.2.1.1

SEISMIC DESIGN CATEGORY DETERMINATION
R301.2.2.1.2 Alternative determination of Seismic Design Category E. Buildings located in Seismic Design Category E in accordance with Figure R301.2(2) are permitted to be reclassified as being in Seismic Design Category D2 provided one of the following is done:

1. A more detailed evaluation of the seismic design category is made in accordance with the provisions and maps of the California Building Code. Buildings located in Seismic Design Category E per Table R301.2.2.1.1, but located in Seismic Design Category D per the California Building Code, may be designed using the Seismic Design Category D2 requirements of this code.

2. Buildings located in Seismic Design Category E that conform to the following additional restrictions are permitted to be constructed in accordance with the provisions for Seismic Design Category D2 of this code:

2.1. All exterior shear wall lines or braced wall panels are in one plane vertically from the foundation to the uppermost story.

2.2. Floors shall not cantilever past the exterior walls.

2.3. The building is within all of the requirements of Section R301.2.2.5 for being considered as regular.

2.4. For buildings over one story in height, the calculated SDS shall not exceed l.25g. (Ord. 0-19-1357, 11-13-2019)

25.03.07: AMENDMENT OF SECTION R301.2.2.6:

Notwithstanding the provisions of section 25.03.01 of this article, items 1, 3 and 5 of section R301.2.2.6 of the Residential Code are amended to read as follows:

1. When exterior shear wall lines or braced wall panels are not in one plane vertically from the foundation to the uppermost story in which they are required.

3. When the end of a braced wall panel occurs over an opening in the wall.

5. When portions of a floor level are vertically offset. (Ord. 0-19-1357, 11-13-2019)

25.03.08: ADDITION OF SECTION R301.2.2.11:

Notwithstanding the provisions of section 25.03.01 of this article, section R301.2.2.11 is added to the Residential Code to read as follows:

R301.2.2.11 Anchorage of Mechanical, Electrical, or Plumbing Components and Equipment. Mechanical, electrical, or plumbing components and equipment shall be anchored to the structure. Anchorage of the components and equipment shall be designed to resist loads in accordance with the International Building Code and ASCE 7, except where the component is positively attached to the structure and flexible connections are provided between the component and associated ductwork, piping, and conduit; and either

1. The component weighs 400 lb (1,780 N) or less and has a center of mass located 4 ft (1.22 m) or less above the supporting structure; or

2. The component weighs 20 lb (89N) or less or, in the case of a distributed system, 5 lb/ft (73 N/m) or less.
(Ord. 0-19-1357, 11-13-2019)

25.03.09: ADDITION OF SECTION R337.1:

Notwithstanding the provisions of section 25.03.01 of this article, section R337 is added to the Residential Code to read as follows:

R337.1 Application-New Buildings. All new residential buildings of any occupancy that are located in the Very High Fire Hazard Severity Zone (VHFHSZ) as designated by the City of San Marino.

R337.2 Application-Additions & Remodels. The addition and remodeling areas of existing building of any occupancy that are located within the Very High Fire Hazard Severity Zone (VHFHSZ) as designated by the city of San Marino.
337.3 Protection of enclosed eaves. The exposed underside of enclosed roof eaves and soffits shall be protected on the exposed underside by one or more of the following:

1. Noncombustible materials.

2. Ignition-resistant building materials.

3. Materials approved for not less than 1-hour fire-resistance-rated construction on the exterior side, as tested in accordance with ASTM E119 or UL 263.

4. 2-inch (51 mm) nominal dimension lumber.

5. 1-inch (25 mm) nominal fire-retardant-treated lumber or 3/4-inch (19.1 mm) nominal fire-retardant-treated plywood, identified for exterior use and complying with Section 2303.2 of the California Building Code.

6. Boxed-in roof eave soffit assemblies with an underside that meets the performance criteria as determined by the Building Official when tested in accordance with the test procedures set forth in ASTM E2957.

7. Boxed-in roof eave soffit assemblies with an underside that meets the performance criteria in accordance with the test procedures set forth in SFM Standard 12-7A-3.

Facias are required and shall be ignition-resistant building materials, fire-retardanttreated wood labeled for exterior use and complying with Section 2303.2 of the California Building Code, materials approved for not less than 1-hour fire-resistance rated construction or 2-inch (51 mm) nominal dimension lumber. 337.3.1 Protection of open eaves. The exposed roof deck on the underside of unenclosed roof eaves shall consist of one or more of the following:

1. Noncombustible material.

2. Ignition-resistant building material.

3. Fire-retardant-treated wood labeled for exterior use and complying with Section 2303.2 of the California Building Code.

4. Materials approved for not less than 1-hour fire-resistance-rated construction on the exterior side, as tested in accordance with ASTM E119 or UL 263.

5. 2-inch (51 mm) nominal dimension lumber.

6. One layer of 5/8-inch (16 mm) Type X gypsum sheathing applied behind an exterior covering on the underside of the roof deck.

7. The exterior portion of a 1-hour fire-resistance-rated exterior assembly, as tested in accordance with ASTM E119 or UL 263, applied to the underside of the roof deck designed for exterior fire exposure, including assemblies using the gypsum panel and sheathing products listed in the Gypsum Association Fire Resistance Design Manual.

Facias, if provided, shall be of fire-retardant-treated wood labeled for exterior use and complying with Section 2303.2 of the California Building Code, ignition-resistant building materials, materials approved for not less than 1-hour fire-resistance-rated construction or 2-inch (51 mm) nominal dimension lumber. 337.10 Vents. Where provided, ventilation openings for enclosed attics, gable ends, ridge ends, under eaves and cornices, enclosed eave soffit spaces, enclosed rafter spaces formed where ceilings are applied directly to the underside of roof rafters, underfloor ventilation, foundations and crawl spaces, or any other opening intended to permit ventilation, either in a horizontal or vertical surface, shall be in accordance with Section 337.10.1 or Section 337.10.2 to resist building ignition from the intrusion of burning embers and flame through the ventilation openings. 337.10.1 Performance requirements. Ventilation openings shall be fully covered with Wildfire Flame and Ember Resistant vents approved and listed by the California State Fire Marshal, or WUI vents, tested in accordance with ASTM E2886, to demonstrate compliance with all the following requirements:

1. There shall be no flaming ignition of the cotton material during the Ember Intrusion Test.

2. There shall be no flaming ignition during the Integrity Test portion of the Flame Intrusion Test.

3. The maximum temperature of the unexposed side of the vent shall not exceed 662°F (350°C).
337.10.2 Off ridge and ridge vents. Vents that are installed on a sloped roof, such as dormer vents, shall comply with all of the following:

1. Vents shall be covered with a mesh where the dimensions of the mesh therein shall be a minimum of 1/16 inch (1.6 mm) and
shall not exceed 1/8 inch (3.2 mm) in diameter.

2. The vent and mesh material shall be noncombustible.

3. The vent and mesh material shall be corrosion resistant. 337.10.3 Vent locations. Gable-end and dormer vents shall be located not less than 10 feet (3048 mm) from lot lines. Underfloor ventilation openings shall be located as close to grade as practical

25.03.1009: AMENDMENT OF SECTION R401.1:

Notwithstanding the provisions of section 25.03.01 of this article, section R401.1 of the Residential Code is amended to read as follows:

R401.1 Application. The provisions of this chapter shall control the design and construction of the foundation and foundation spaces for all buildings. In addition to the provisions of this chapter, the design and construction of foundations in areas prone to flooding as established by Table R301.2(1) shall meet the provisions of Section R322. Wood foundations shall be designed and installed in accordance with AWCF&PA PWF.

Exception: The provisions of this chapter shall be permitted to be used for wood foundations only in the following situations:

1. In buildings that have no more than two floors and a roof.

2. When interior basement and foundation walls are constructed at intervals not exceeding 50 feet (15 240 mm).

Wood foundations in Seismic Design Category D0, D1 or D2 shall not be permitted.

Exception: In non-occupied, single-story, detached storage sheds and similar uses other than carport or garage, provided the gross floor area does not exceed 200 square feet, the plate height does not exceed 12 feet in height above the grade plane at any point, and the maximum roof projection does not exceed 24 inches.
(Ord. 0-19-1357, 11-13-2019)

25.03.101: AMENDMENT OF SECTIONS R403.1.2, R403.1.3 AND R403.1.5:

Notwithstanding the provisions of section 25.03.01 of this article, sections R403.1.2, R403.1.3 and R403.1.5 of the Residential Code are amended to read as follows:

R403.1.2 Continuous footing in Seismic Design Categories Do, D1i and D2. The braced wall panels at exterior walls of buildings located in Seismic Design Categories D0, D1 and D2 shall be supported by continuous footings. All required interior braced wall panels in buildings shall be supported by continuous footings.

R403.1.3 Seismic reinforcing. Concrete footings located in Seismic Design Categories D0, D1 and D2, as established in Table R301.2(1), shall have minimum reinforcement. Bottom reinforcement shall be located a minimum of 3 inches (76 mm) clear from the bottom of the footing.

In Seismic Design Categories D0, D1 and D2 where construction joint is created between a concrete footing and a stem wall, a minimum of one No. 4 bar shall be installed at not more than 4 feet (1219 mm) on center. The vertical bar shall extend to 3 inches (76 mm) clear of the bottom of the footing, have a standard hook and extend a minimum of 14 inches (357 mm) into the stem wall.

In Seismic Design Categories D0, D1 and D2 where a grouted masonry stem wall is supported on a concrete footing and stem wall, a minimum of one No. 4 bar shall be installed at not more than 4 feet (1219 mm) on center. The vertical bar shall extend to 3 inches (76 mm) clear of the bottom of the footing and have a standard hook.

In Seismic Design Categories D0, D1 and D2 masonry stem walls without solid grout and vertical reinforcing are not permitted.

Exception: In detached one- and two-family dwellings located in Seismic Design Category A, B or C which are three stories or less in height and constructed with stud bearing walls, isolated plain concrete footings, supporting columns or pedestals are permitted.

R403.1.5 Slope. The top surface of footings shall be level. The bottom surface of footings shall be permitted to have a slope not exceeding one unit vertical in 10 units horizontal (10-percent slope). Footings shall be stepped where it is necessary to change the elevation of the top surface of the footing or where the surface of the ground slopes more than one unit vertical in 10 units horizontal (10-percent slope).

For structures located in Seismic Design Categories D0, D1 or D2, stepped footings shall be reinforced with four No. 4 rebar. Two bars shall be place at the top and bottom of the footings as shown in Figure R403.1.5.

FIGURE R403.1.5

STEPPED FOOTING
(Ord. 0-19-1357, 11-13-2019)

25.03.121: AMENDMENT OF SECTION R404.2:

Notwithstanding the provisions of section 25.03.01 of this article, section R404.2 of the Residential Code is amended to read as follows:

R404.2 Wood foundation walls. Wood foundation walls shall be constructed in accordance with the provisions of Sections R404.2.1 through R404.2.6 and with the details shown in Figures R403.1(2) and R403.1(3). Wood foundation walls shall not be used for structures located in Seismic Design Category D0, D1 or D2.
(Ord. 0-19-1357, 11-13-2019)

25.03.132: AMENDMENT OF SECTION R501.1:

Notwithstanding the provisions of section 25.03.01 of this article, section R501.1 of the Residential Code is amended to read as follows:

R501.1 Application. The provisions of this chapter shall control the design and construction of the floors for all buildings including the floors of attic spaces used to house mechanical or plumbing fixtures and equipment. Mechanical or plumbing fixtures and equipment shall be attached (or anchored) to the structure in accordance with Section R301.2.2.11. (Ord. 0-19-1357, 11-13-2019)

25.03.143: ADDITION OF SECTION R503.2.4:

Notwithstanding the provisions of section 25.03.01 of this article, section R503.2.4 is added to the Residential Code to read as follows:

R503.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms with a dimension perpendicular to the joist that is greater than 4 feet (1.2 m) shall be constructed in accordance with Figure R503.2.4.
a. Blockings shall be provided beyond headers.
b. Metal ties not less than 0.058 inch [1.47 mm (16 galvanized gage)] by 1.5 inches (38 mm) wide with eight 16d common nails on each side of the header-joist intersection. The metal ties shall have a minimum yield of 33,000 psi (227 MPa).
c. Openings in diaphragms shall be further limited in accordance with Section R301.2.2.2.5.

FIGURE R503.2.4

OPENINGS IN HORIZONTAL DIAPHRAGMS
(Ord. 0-19-1357, 11-13-2019)

25.03.1514: AMENDMENT OF TABLE R602.3(1):

Notwithstanding the provisions of section 25.03.01 of this article, lines 37 and 38 of table R602.3(1) of the Residential Code are amended to read as follows:

TABLE R602.3(1)

FASTENER SCHEDULE FOR STRUCTURAL MEMBERS

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 mile per hour = 0.447 m/s; 1 Ksi = 6.895 MPa. a. All nails arc smooth-common, box or deformed shanks except where otherwise stated. Nails used for framing and sheathing connections shall have minimum average bending yield strengths as shown: 80 ksi for shank diameter of 0.192 inch (20d common nail), 90 ksi for shank diameters larger than 0.142 inch but not larger than 0.177 inch, and 100 ksi for shank diameters of 0.142 inch or less.
b. Staples are 16 gage wire and have a minimum 7/6-inch on diameter crown width. b. c. Nails shall be spaced at not more than 6 inches on center at all supports where spans are 48 inches or greater.
c.d. Four-foot by 8-fool or 4-foot by 9-foot panels shall be applied vertically. d.e. Spacing of fasteners not included in this table shall be based on Table R602.3(2). e.f. For regions having basic wind speed of 110 mph or greater, 8d deformed (2'/2"x 0.120) nails shall be used for attaching plywood and wood structural panel roof sheathing to framing within minimum 4S-inch distance from gable end walls, if mean roof height is more than 25 feet, up to 35 feet maximum.
f.g. For regions having bask wind speed of 100 mph or less, nails for attaching wood structural panel roof sheathing to gable end wall framing shall be spaced 6 inches on center. When basic wind speed is greater than 100 mph, nails for attaching panel roof sheathing to intermediate supports shall be spaced 6 inches on center for minimum 48-inch distance from ridges, eaves and gable end walls; and 4 inches on center to gable end wall framing. g.h. Gypsum sheathing shall conform to ASTM C 1396 and shall be installed in accordance with GA 253. Fiberboard sheathing shall conform to ASTM C 208. h.i. Spacing of fasteners on floor sheathing panel edges applies to panel edges supported by framing members and required blocking and at all floor perimeters only. Spacing of fasteners on roof sheathing panel edges applies to panel edges supported by framing members and required blocking. Blocking of roof or floor sheathing panel edges perpendicular to the framing members need not be provided except as required by other provisions of this code. Floor perimeter shall be supported by framing members or solid blocking.
i.j. Where a rafter is fastened to an adjacent parallel ceiling joist in accordance with this schedule, provide two toe nails on one side of the rafter and toe nails from the ceiling joist to top plate in accordance with this schedule. The toe nail on the opposite side of the rafter shall not be required.
j.K. Use of staples in braced wall panels shall be prohibited in Seismic Design Category D0, D1, or D2.
(Ord. 0-19-1357, 11-13-2019)

25.03.1516: AMENDMENT OF TABLE R602.3(2):

Notwithstanding the provisions of section 25.03.01 of this article, footnote "b" of table R602.3(2) of the Residential Code is amended to read as follows:
b. Staples shall have a minimum crown width of 7/16-inch on diameter except as noted. Use of staples in roof, floor, subfloor, and braced wall panels shall be prohibited in Seismic Design Category D0, D1, or D2.
(Ord. 0-19-1357, 11-13-2019)

25.03.176: AMENDMENT OF SECTION R602.10.3(3):

Notwithstanding the provisions of section 25.03.01 of this article, table R602.10.3(3) of the Residential Code is amended to read as follows:

(Ord. 0-19-1357, 11-13-2019)

25.03.187: AMENDMENT OF TABLE R602.10.4:

Notwithstanding the provisions of section 25.03.01 of this article, table R602.10.4 of the Residential Code is amended to read as follows:

(Ord. 0-19-1357, 11-13-2019)

25.03.198: AMENDMENT OF FIGURE R602.10.6.1:

Notwithstanding the provisions of section 25.03.01 of this article, figure R602.10.6.1 of the Residential Code is amended to read as follows:
(Ord. 0-19-1357, 11-13-2019)

25.03.2019: AMENDMENT OF FIGURE R602.10.6.2:

Notwithstanding the provisions of section 25.03.01 of this article, figure R602.10.6.2 of the Residential Code is amended to read as follows:

(Ord. 0-19-1357, 11-13-2019)

25.03.210: AMENDMENT OF TABLE R602.10.5:

Notwithstanding the provisions of section 25.03.01 of this article, table R602.10.5 of the Residential Code is amended to read as follows:

TABLE R602.10.5 602.10.6.5.4

MINIMUM LENGTH OF BRACED WALL PANELS

For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, I mile per hour=Q.447 m/s. NP = Not Permitted. a. Linear interpolation shall be permitted.
b. Use the actual length when it is greater than or equal lo the minimum length. c. Maximum header height for PFH is 10 feet in accordance with Figure R602.10.6.2, but wall height may be increased to 12 feet with pony wall.
d. Maximum opening height for PFG is 10 feet in accordance with Figure R602.10.6.3. but wall height maybe increased to 12 feet with pony wall,
e. Maximum opening height for CS-PF is 10 feet in accordance with Figure R602.10.6.4. but wall height may be increased to 12 feet with pony wall. (Ord. 0-19-1357, 11-13-2019)

25.03.221: AMENDMENT OF SECTION R602.10.2.3:

Notwithstanding the provisions of section 25.03.01 of this article, section R602.10.2.3 of the Residential Code is amended to read as follows:

R602.10.2.3 Minimum number of braced wall panels. Braced wall lines with a length of 16 feet (4877 mm) or less shall have a minimum of two braced wall panels of any length or one braced wall panel equal to 48 inches (1219 mm) or more. Braced wall lines greater than 16 feet (4877 mm) shall have a minimum of two braced wall panels. No braced wall panel shall be less than 48 inches in length in Seismic Design Category D0, D1, or D2. (Ord. 0-19-1357, 11-13-2019)

25.03.232: AMENDMENT OF SECTION R606.4.4:

Notwithstanding the provisions of section 25.03.01 of this article, section R606.4.4 of the Residential Code is amended to read as follows:

R606.4.4 Parapet walls. Unreinforced solid masonry parapet walls shall not be less than 8 inches (203 mm) thick and their height shall not exceed four times their thickness. Unreinforced hollow unit masonry parapet walls shall be not less than 8 inches (203 mm) thick, and their height shall not exceed three times their thickness. Masonry parapet walls in areas subject to wind loads of 30 pounds per square foot (1.44 kPa) or located in Seismic Design Category D0, DI or D2, or on townhouses in Seismic Design Category C shall be reinforced in accordance with Section R606.12.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.03.243: AMENDMENT OF SECTION R606.12.2.2.3:

Notwithstanding the provisions of Section 25.03.01 of this article, section R606.12.2.2.3 of the Residential Code is amended to read as follows:

R606.12.2.2.3 Reinforcement requirements for masonry elements. Masonry elements listed in Section R606.12.2.2.2 shall be reinforced in either the horizontal or vertical direction as shown in Figure R606.11(32) and in accordance with the following:

1. Horizontal reinforcement. Horizontal joint reinforcement shall consist of at least one No. 4 bar spaced not more than 48 inches (1219 mm). Horizontal reinforcement shall be provided within 16 inches (406 mm) of the top and bottom of these masonry elements.

2. Vertical reinforcement. Vertical reinforcement shall consist of at least one No. 4 bar spaced not more than 48 inches (1219 mm). Vertical reinforcement shall be within 8 inches (406mm) of the ends of masonry walls.
(Ord. 0-19-1357, 11-13-2019)

25.03.2524: AMENDMENT OF SECTION R602.3.2:

Notwithstanding the provisions of section 25.03.01 of this article, section R602.3.2, Exception, of the Residential Code is amended to read as follows:

Exception: In other than Seismic Design Category D0, D1 or D2, a single top plate may be installed in stud walls, provided the plate is adequately tied at joints, corners and interesting walls by a minimum 3-inch-by-6-inch by a 0.036-inch-thick (76 mm by 152 mm by 0.914 mm) galvanized steel plate that is nailed to each wall or segment of wall by six 8d nails on each side, provided the rafters or joists are centered over the studs with a tolerance of no more than 1 inch (25 mm). The top plate may be omitted over lintels that are adequately tied to adjacent wall sections with steel plates or equivalent as previously described. (Ord. 0-19-1357, 11-13-2019)

25.03.265: ADDITION OF SECTION R803.2.4:

Notwithstanding the provisions of section 25.03.01 of this article, section R803.2.4 is added to the Residential Code to read as follows:

R803.2.4 Openings in horizontal diaphragms. Openings in horizontal diaphragms shall conform with Section R503.2.4.
(Ord. 0-19-1357, 11-13-2019)

25.03.276: AMENDMENT OF SECTION R1001.3.1:

Notwithstanding the provisions of section 25.03.01 of this article, section R1001.3.1 of the Residential Code is amended to read as follows:

R1001.3.1Vertical reinforcing. For chimneys up to 40 inches (1016 mm) wide, four No. 4 continuous vertical bars adequately anchored into the concrete foundation shall be placed between wythes of solid masonry or within the cells of hollow unit masonry and grouted in accordance with Section R609. Grout shall be prevented from bonding with the flue liner so that the flue liner is free to move with thermal expansion. For chimneys more than 40 inches (1016 mm) wide, two additional No. 4 vertical bars adequately anchored into the concrete foundation shall be provided for each additional flue incorporated into the chimney or for each additional 40 inches (1016 mm) in width or fraction thereof.
(Ord. 0-19-1357, 11-13-2019)
Section 4. New Article 04 Plumbing Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 04

PLUMBING CODE
SECTION:

25.04.01: Plumbing Code Adopted

25.04.02: Amendment Of Section 103.3

25.04.03: Amendment Of Sections 104.3.2 And 104.3.3

25.04.04: Amendment Of Section 104.4.3

25.04.05: Amendment Of Section 104.4.5

25.04.06: Amendment Of Section 104.5

25.04.07: Amendment Of Section 105.2.6

25.04.08: Amendment Of Sections 106.1 And 106.3

25.04.09: Amendment Of Section 203.0

25.04.10: Addition Amendment Of Section 312.13

25.04.11: Addition Amendment Of Section 511.0

25.04.12: Addition Of Section 713.8

25.04.13: Addition Amendment Of Section 906.8

25.04.01: PLUMBING CODE ADOPTED:

Except as hereinafter provided, the California Plumbing Code, 20252 Edition, based on the 20241 Uniform Plumbing Code as published by the International Association of Plumbing and Mechanical Officials, including all appendices, is hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the Plumbing Code of the City. A copy of said Code has been deposited in the office of the City Clerk and shall be, at all times, maintained by the City Clerk for use and examination by the public. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.04.02: AMENDMENT OF SECTION 103.3:

Notwithstanding the provisions of section 25.04.01 of this article, the first paragraph of section 103.3 of the Plumbing Code is amended to read as follows:

Issuance. The Building Official or his/her designee shall review the application, plans and specifications and other data filed by an applicant for a permit. Other departments of this jurisdiction may also review plans. If the Building Official or his/her designee finds that the work described in an application for permit and the plans, specifications and other data filed therewith conform to the requirements of the Plumbing Code and other pertinent laws and ordinances, and that the fees established by resolution of the City Council have been paid, he/she shall issue a permit therefore to the applicant.
(Ord. 0-19-1357, 11-13-2019)

25.04.03: AMENDMENT OF SECTIONS 104.3.2 AND 104.3.3:

Notwithstanding the provisions of section 25.04.01 of this article, the first paragraph of section 104.3.2, and section 104.3.3, of the Plumbing Code are amended to read as follows:
104.3.2 Plan Review Fees. When a plan or other data are required to be submitted by Section 104.3.1, a plan review fee shall be paid at the time of submitting plans and specifications for review. The plan review fees for plumbing work shall be equal to 100 percent of the total permit fee as established by resolution of the City Council. When plans are incomplete or changed so as to require additional plan review, a fee shall be charged in the amount established by resolution of the City Council.
104.3.3 Expiration of Plan Review. Applications for which no permit is issued within 180 days following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon request by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. No application shall be extended more than once. In order to renew action on an application after expiration, the applicant shall resubmit plans and pay a new plan review fee.
(Ord. 0-19-1357, 11-13-2019)

25.04.04: AMENDMENT OF SECTION 104.4.3:

Notwithstanding the provisions of section 25.04.01 of this article, the first paragraph of section 104.4.3 of the Plumbing Code is amended to read as follows:

Expiration. Plumbing permits will remain valid if the work on the site authorized by that permit is commenced within 12 months after its issuance, unless the permittee has abandoned the work authorized by the permit. Before such work can be recommenced, the permit shall first be renewed, provided no changes have been made or will be made in the original plans and specifications for such work. If an applicant wishes to renew a permit that has been expired for less than 180 days, 50% of the original fees paid shall be required to renew the permit. If an applicant wishes to renew a permit that has been expired for more than 180 days, 100% of the original fees paid shall be required to renew the permit. The Building Official may extend the permit expiration date for a period not exceeding 180 days on written request (submitted prior to the expiration date) by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. No application shall be extended more than once. (Ord. 0-19-1357, 11-13-2019)

25.04.05: AMENDMENT OF SECTION 104.4.5:

Notwithstanding the provisions of section 25.04.01 of this article, section 104.4.5 of the Plumbing Code is amended to read as follows:

Suspension or Revocation. The Building Official or his/her designee may, in writing, suspend or revoke a permit issued under the provisions of this Code whenever the permit is issued in error or on the basis of incorrect information supplied or in violation of other ordinances or regulations of the City.
(Ord. 0-19-1357, 11-13-2019)

25.04.06: AMENDMENT OF SECTION 104.5:

Notwithstanding the provisions of section 25.04.01 of this article, section 104.5 of the Plumbing Code is amended to read as follows:
104.5 Permit Fees. All fees pursuant to the Plumbing Code as set forth in Table No. 104.5 shall be established by resolution of the City Council.
104.5.1 Whenever any work for which a permit is required by the Plumbing Code has been commenced without first obtaining said permit, a special investigation shall be made before a permit may be issued for such work.
104.5.2 An investigation fee, in addition to the permit fee, shall be collected whether or not a permit is then or subsequently issued. The investigation fee shall be equal to the amount of the permit fee that would be required by the Plumbing Code if a permit were to be issued. The payment of such investigation fee shall not exempt any person from compliance with all other provisions of the Plumbing Code nor from any penalty prescribed by law. 104.5.3 Fee Refunds.
104.5.3(1) The Building Official may authorize the refunding of any fee paid hereunder which was erroneously paid or collected.
104.5.3(2) The Building Official may authorize refunding of not more than 80 percent of the permit fee paid when no work has been done under a permit issued in accordance with the Plumbing Code.
104.5.3(3) The Building Official shall not authorize the refunding of any fee paid except upon written application filed by the original permittee not later than one hundred eighty (180) days after the date of fee payment.
(Ord. 0-19-1357, 11-13-2019)

25.04.07: AMENDMENT OF SECTION 105.2.6:

Notwithstanding the provisions of section 25.04.01 of this article, the fourth paragraph of section 105.2.6 of the Plumbing Code is amended to read as follows:

To obtain reinspection, the applicant shall file an application therefor in writing upon a form furnished for that purpose and pay the reinspection fee established by resolution of the City Council.
(Ord. 0-19-1357, 11-13-2019)

25.04.08: AMENDMENT OF SECTIONS 106.1 AND 106.3:

Notwithstanding the provisions of section 25.04.01 of this article, sections 106.1 and 160.3 of the Plumbing Code are amended to read as follows:
106.1 Violations. It shall be unlawful for any person, firm or corporation to erect, construct, enlarge, alter, repair, move, improve, remove, convert, demolish, equip, use, or maintain any plumbing or permit the same to be done in violation of the Plumbing Code. 106.3 Penalties. Any person, firm or corporation violating any provision of the Plumbing Code shall be deemed guilty of a misdemeanor, and, upon conviction thereof, shall be punishable as provided in Section 01.04.03 A of this Code. Each separate day or any portion thereof, during which any violation of this code occurs or continues, shall be deemed to constitute a separate offence.
(Ord. 0-19-1357, 11-13-2019)

25.04.09: AMENDMENT OF SECTION 203.0:

Notwithstanding the provisions of section 25.04.01 of this article, section 203.0 of the Plumbing Code is amended by revising the following definitions to read as follows:

Accessible. "Accessible," when applied to a fixture, connection, appliance, or equipment, shall mean having access thereto, but which first may require the removal of an access panel, door, or similar obstruction; "readily accessible" shall mean direct access without the necessity of removing any panel, door, or similar obstruction. Attic and underfloor areas are to be considered "accessible."
Authority Having Jurisdiction. Whenever the term "Authority Having Jurisdiction" is used in the Plumbing Code, it shall mean the Building Official or his/her authorized representative. (Ord. 0-19-1357, 11-13-2019)

25.04.10: ADDITION AMENDMENT OF SECTION 312.13:

Notwithstanding the provisions of section 25.04.01 of this article, section 312.13 is added to the Plumbing Code read as follows:
312.13 Soil, waste, water or other pipe or conduit, except downspouts, shall not be installed or permitted on the outside of a building unless the Building Official deems it necessary. (Ord. 0-19-1357, 11-13-2019)

25.04.11: ADDITION AMENDMENT OF SECTION 511.0:

Notwithstanding the provisions of section 25.04.01 of this article, section 511 is added to the Plumbing Code read as follows:
511.0 No vent shall terminate in a location that is visible from the parkway across the street from the subject property, or to the side elevation facing a side street on a corner lot unless the Building Official deems it necessary.
(Ord. 0-19-1357, 11-13-2019)

25.04.12: ADDITION OF SECTION 713.8:

Notwithstanding the provisions of section 25.04.01 of this article, section 713.8 is added to the Plumbing Code read as follows:
713.8 The City Engineer shall determine the availability of the sewer lines. No person shall construct, or enlarge a new or existing cesspool if a sewer line has been declared available. (Ord. 0-19-1357, 11-13-2019)

25.04.13: ADDITION AMENDMENT OF SECTION 906.8:

Notwithstanding the provisions of section 25.04.01 of this article, section 906.8 is added to the Plumbing Code to read as follows:
906.8 No vent shall terminate in a location that is visible from the parkway across the street from the subject property, or to the side elevation facing a side street on a corner lot unless the Building Official deems it necessary.
(Ord. 0-19-1357, 11-13-2019)
Section 5. New Article 05 Mechanical Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 05

MECHANICAL CODE
SECTION:

25.05.01: Mechanical Code Adopted

25.05.02: Amendment Of Section 1043.43

25.05.03: Amendment Of Sections 104.3.2 And 104.3.3

25.05.04: Amendment Of Sections 104.4.3 And 104.4.5

25.05.05: Amendment Of Section 104.5

25.05.06: Amendment Of Section 107.1

25.05.07: Amendment Of Section 106.0

25.05.01: MECHANICAL CODE ADOPTED:

Except as hereinafter provided, the California Mechanical Code, 20252 Edition, based on the 20241 Uniform Mechanical Code as published by the International Association of Plumbing and Mechanical Officials, including all appendices, is hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the Mechanical Code of the City. A copy of such Code shall be located in the office of the City Clerk and shall be, at all times, maintained by the Planning and Building Department for use and examination by the public. For the purposes of this Code, the Building Official shall be the Building Official. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.05.02: AMENDMENT OF SECTION 1043.3:4
Notwithstanding the provisions of section 25.05.01 of this article, section 103.3 of the Mechanical Code is amended to include an additional paragraph to read as follows:

The Building Official shall review applications, plans, specifications, computations and other data filed by an applicant for a permit. Such plans may be reviewed by other departments of this City to verify compliance with applicable laws under their jurisdiction. If the Building Official finds that the work described in an application for a permit and the plans, specifications and other data filed therewith conform to the requirements of the Mechanical Code and other pertinent laws and ordinances and that the fees established by Resolution of the City Council have been paid, the Building Official shall issue a permit therefor to the applicant. (Ord. 0-19-1357, 11-13-2019)

25.05.03: AMENDMENT OF SECTIONS 104.3.2 AND 104.3.3:

Notwithstanding the provisions of section 25.05.01 of this article, sections 104.3.2 and 104.3.3 of the Mechanical Code are amended to read as follows:
104.3.2 Plan Review Fees. When a plan or other data are required to be submitted by this code a plan review fee shall be paid at the time of submitting plans and specifications for review. The plan review fees for mechanical work shall be equal to 100 percent of the total permit fee as established by resolution of the City Council. The plan review fees specified in this subsection are separate fees from the permit fees specified in Section 104.5 and are in addition to the permit fees.

When plans are incomplete or changed so as to require additional plan review, a fee shall be charged in the amount established by resolution of the City Council. 104.3.3 Expiration of Plan Review. Applications for which no permit is issued within 180 days following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon request by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. No application shall be extended more than once. In order to renew action on an application after expiration the applicant shall resubmit plans and pay a new plan review fee.
(Ord. 0-19-1357, 11-13-2019)

25.05.04: AMENDMENT OF SECTIONS 104.4.3 AND 104.4.5:

Notwithstanding the provisions of section 25.05.01 of this article, sections 104.4.3 and 104.4.5 of the Mechanical Code are amended to read as follows:
104.4.3 Expiration. Mechanical permits will remain valid if the work on the site authorized by that permit is commenced within 12 months after its issuance, unless the permittee has abandoned the work authorized by the permit. Before such work can be recommenced, the permit shall first be renewed, provided no changes have been made or will be made in the original plans and specifications for such work. If an applicant wishes to renew a permit that has been expired for less than 180 days, 50% of the original fees paid shall be required to renew the permit. If an applicant wishes to renew a permit that has been expired for more than 180 days, 100% of the original fees paid shall be required to renew the permit. The Building Official may extend the permit expiration date for a period not exceeding 180 days on written request (submitted prior to the expiration date) by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. No application shall be extended more than once.
104.4.5 Suspension or Revocation. The Building Official may, in writing, suspend or revoke a permit issued under the provisions of the City Code whenever the permit is issued in error or on the basis of incorrect information supplied or in violation of other ordinances or regulations of the City.
(Ord. 0-19-1357, 11-13-2019)

25.05.05: AMENDMENT OF SECTION 104.5:

Notwithstanding the provisions of section 25.05.01 of this article, section 104.5 of the Mechanical Code is amended to read as follows:
104.5 FEES.

All fees pursuant to the Mechanical Code shall be as established by and set forth in a resolution of the City Council.
104.5.1 Permit Fees. All fees pursuant to the Mechanical Code shall be as amended and established by resolution of the City Council.
104.5.2 Investigation. Whenever any work which requires a permit pursuant to the Mechanical Code has been commenced without first obtaining said permit, a special Investigation shall be made before a permit may be issued for such work.
104.5.2.1 Fee. An investigation fee, in addition to the permit fee, shall be collected whether or not a permit fee is then or subsequently issued. The investigation fee shall be equal to the amount of the permit fee that would be required by the City Code if a permit were to be issued. The payment of such investigation fee shall not exempt any person from compliance with all other provisions of the Mechanical Code nor from any penalty prescribed by law. 104.5.3 Fee Refunds.
104.5.3(1) The Building Official may authorize the refunding of any fee paid hereunder that was erroneously paid or collected.
104.5.3(2) The Building Official may authorize the refunding of not more than 80 percent of the permit fee paid when no work has been done under a permit issued in accordance with the Mechanical Code.
104.5.3(3) The Planning and Building Department shall not authorize refunding of any fee paid except upon written application filed by the original permittee not later than one hundred eighty (180) days after the date of fee payment.
(Ord. 0-19-1357, 11-13-2019)

25.05.06: AMENDMENT OF SECTION 107.1:

Notwithstanding the provisions of section 25.05.01 of this article, section 107.1 of the Mechanical Code is hereby amended to read as follows:
107.1 General. In order to hear and decide appeals of orders, decisions or determinations made by the Building Official relative to the application and interpretation of the Mechanical Code, there shall be and is hereby created a Board of Appeals consisting of the members of the City Council.

The Building Official shall be an ex officio member of and shall act as Secretary to said Board but shall have no vote on any matter before the Board. The Board shall adopt rules of procedures for conducting its business, and shall render all decisions and findings in writing to the appellant with a duplicate copy to the Building Official. The Board may request the services of members of the community who are qualified by experience and training to interpret matters pertaining to the Mechanical Code to act as technical assistants to the Board. Technical assistants shall have no vote on any matter before the Board.
(Ord. 0-19-1357, 11-13-2019)

25.05.07: AMENDMENT OF SECTION 106.0:

Notwithstanding the provisions of section 25.05.01 of this article, section 106.0 of the Mechanical Code is amended to read as follows:
106.10 Violations. It shall be unlawful for any person, firm or corporation to erect, construct, enlarge, alter, repair, move, impound, remove, convert or demolish, equip, use or maintain mechanical systems or equipment or cause or permit the same to be done in violation of the Mechanical Code.

It is hereby declared that any violation of the Mechanical Code constitutes a public nuisance, and in addition to any other remedies provided by the Mechanical Code for its enforcement, the administrative authority may bring civil suit to enjoin the violation of any provisions of the Mechanical Code.

Any person, firm or corporation violating any of the provisions of the Mechanical Code shall be deemed guilty of a misdemeanor and upon conviction thereof shall be punishable as provided in Section 01.04.03 A of this Code. Each separate day or any portion thereof during which violation of the Mechanical Code occurs or continues shall be deemed to constitute a separate offense, and upon conviction thereof shall be punishable as herein provided. (Ord. 0-19-1357, 11-13-2019)
Section 6. New Article 06 Electrical Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 06

ELECTRICAL CODE
SECTION:

25.06.01: Electrical Code Adopted

25.06.02: Amendment Of Article 100

25.06.03: Fees And Expiration

25.06.04: Additions To Electrical Code

25.06.05: Service Entrance Panels

25.06.06: Grounding And Bonding Connections

25.06.07: Use Of Factory Assembled Conduits

25.06.08: Use Of Aluminum

25.06.09: Service Entrance - Services

25.06.10: Amendment To Section 250.50

25.06.11: Addition Of Section 690.19

25.06.12: Violations

25.06.01: ELECTRICAL CODE ADOPTED:

Except as hereinafter provided, the California Electrical Code, 20252 Edition, based on the 20241 National Electrical Code as published by the National Fire Protection Association, including all annexes, is hereby adopted by reference and incorporated herein as though set forth herein in full and shall constitute the Electrical Code of the City. A copy of such code shall be located in the Planning and Building Department and shall be, at all times, maintained by the Planning and Building Department for use and examination by the public. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.06.02: AMENDMENT OF ARTICLE 100:

Notwithstanding the provisions of section 25.06.01 of this article, article 100 of the Electrical Code is amended by amending the definition of "Accessible, Readily" to read as follows:

Accessible, Readily: (Readily Accessible.) Capable of being reached quickly for operation, renewal, or inspections, without requiring those to whom ready access is requisite to climb over or remove obstacles or to resort to portable ladders, chairs, etc. (See "Accessible.") Attic and crawl spaces are not considered readily accessible.
(Ord. 0-19-1357, 11-13-2019)

25.06.03: FEES AND EXPIRATION:

Notwithstanding the provisions of section 25.06.01 of this article, all fees pursuant to the Electrical Code shall be those amounts established by resolution of the City Council.

Plan Review Fees. When a plan or other data are required to be submitted by this code a plan review fee shall be paid at the time of submitting plans and specifications for review. The plan review fees for electrical work shall be equal to 100 percent of the total permit fee as established by resolution of the City Council. The plan review fees specified in this subsection are separate fees from the permit fees and are in addition to the permit fees. When plans are incomplete or changed so as to require additional plan review, a fee shall be charged in the amount established by resolution of the City Council.

Expiration of Plan Review. Applications for which no permit is issued within 180 days following the date of application shall expire by limitation, and plans and other data submitted for review may thereafter be returned to the applicant or destroyed by the Building Official. The Building Official may extend the time for action by the applicant for a period not exceeding 180 days upon request by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. No application shall be extended more than once. In order to renew action on an application after expiration the applicant shall resubmit plans and pay a new plan review fee.

Investigation. Whenever any work which requires a permit pursuant to the Electrical Code has been commenced without first obtaining said permit, a special Investigation shall be made before a permit may be issued for such work.

Investigation Fee. An investigation fee, in addition to the permit fee, shall be collected whether or not a permit fee is then or subsequently issued. The investigation fee shall be equal to the amount of the permit fee that would be required by the City Code if a permit were to be issued. The payment of such investigation fee shall not exempt any person from compliance with all other provisions of the Electrical Code nor from any penalty prescribed by law.

Fee Refunds. The Building Official may authorize the refunding of any fee paid hereunder that was erroneously paid or collected. The Building Official may authorize the refunding of not more than 80 percent of the permit fee paid when no work has been done under a permit issued in accordance with the Electrical Code. The Planning and Building Department shall not authorize refunding of any fee paid except upon written application filed by the original permittee not later than one hundred eighty (180) days after the date of fee payment.

Expiration. Electrical permits will remain valid if the work on the site authorized by that permit is commenced within 12 months after its issuance, unless the permittee has abandoned the work authorized by the permit. Before such work can be recommenced, the permit shall first be renewed, provided no changes have been made or will be made in the original plans and specifications for such work. If an applicant wishes to renew a permit that has been expired for less than 180 days, 50% of the original fees paid shall be required to renew the permit. If an applicant wishes to renew a permit that has been expired for more than 180 days, 100% of the original fees paid shall be required to renew the permit. The Building Official may extend the permit expiration date for a period not exceeding 180 days on written request (submitted prior to the expiration date) by the applicant showing that circumstances beyond the control of the applicant have prevented action from being taken. No application shall be extended more than once. (Ord. 0-19-1357, 11-13-2019)

25.06.04: ADDITIONS TO ELECTRICAL CODE:

Notwithstanding the provisions of section 25.06.01 of this article, the Electrical Code is amended by adding the sections as set forth in sections 25.06.05 through 25.06.11 of this article. (Ord. 0-19-1357, 11-13-2019)

25.06.05: SERVICE ENTRANCE PANELS:

A. All new residences shall be provided with a minimum service capacity of not less than two hundred (200) amperes main. Service conduit shall be two-inch (2") conduit.

B. On existing dwellings if the service is replaced, the minimum service shall be one hundred (100) amperes main. Service conduit shall be one and one-half inches (1-½").

C. Branch circuit panel shall contain space for a minimum of twenty (20) single pole overcurrent devices.
(Ord. 0-19-1357, 11-13-2019)

25.06.06: GROUNDING AND BONDING CONNECTIONS:

A. The connection of grounding conductor to grounding electrode shall be readily accessible.

B. The connection of the bond from the grounding conductor to the cold water and gas systems shall be readily accessible.

C. All conduit shall contain a green ground wire.
(Ord. 0-19-1357, 11-13-2019)

25.06.07: USE OF FACTORY ASSEMBLED CONDUITS:

Notwithstanding any provision of the Electrical Code to the contrary, the following is prohibited in new installations:

A. Factory assembled conduits, such as:

1. Mineral insulated sheathed cable.

2. Armored cable unless:
a. Factory assembled in an Underwriters Laboratory approved fixture; b. Green insulated copper grounding conductor; and
c. Is used for applications not to exceed nine feet (9') from a power source to a single fixture.

3. Extension of any knob and tube.
(Ord. 0-19-1357, 11-13-2019)

25.06.08: USE OF ALUMINUM:

Notwithstanding any provision of the Electrical Code to the contrary, the following are prohibited in new installations:

A. Aluminum wire is not permitted.

B. Aluminum conduit is not approved as a self-grounding conduit. (Ord. 0-19-1357, 11-13-2019)

25.06.09: SERVICE ENTRANCE - SERVICES:

A. New service entrance conductors on all commercial buildings shall be installed underground.

B. A contractor licensed C-10 or B-1 must apply for the permit for any new service or service change out.
(Ord. 0-19-1357, 11-13-2019)

25.06.10: AMENDMENT TO SECTION 250.50:

Notwithstanding the provisions of section 25.06.01 , an additional exception is added to section 250.50 to read as follows:

Exception: Grounding of electrical services replaced in existing residential buildings.

When an electrical service in an existing R1 or R3 occupancy is replaced or upgraded, and the material of the water pipe in direct contact with the earth is unknown, the connection of the grounding conductor to the interior metal water pipe may be made at any accessible point, provided that at least one grounding electrode of a type specified in Sections 250.50 or 250.52 is installed as close as possible to the service and connected directly to the service equipment with an independent grounding electrode conductor.
(Ord. 0-19-1357, 11-13-2019)

25.06.11: ADDITION OF SECTION 690.19:

Notwithstanding the provisions of Section 25.06.01 , Section 690.19 is added to the Electrical Code to read as follows:
690.19 Disconnecting Means for Multiple Arrays. Where more than one array is combined to form a single output rated more than 50 volts and/or 10 amperes, a disconnecting means rated for the output shall be installed immediately adjacent to the combiner box on the output side.

Exception: If the combiner box is located adjacent to the inverter(s), the disconnecting means as stated above shall not be required.
(Ord. 0-19-1357, 11-13-2019)

25.06.12: VIOLATIONS:

Any person, firm or corporation violating any of the provisions or failing to comply with any of the mandatory requirements of the Electrical Code shall be guilty of a misdemeanor and upon conviction thereof shall be punishable as provided in section 01.04.03 A of this Code. Each such person shall be guilty of a separate offense for each and every day during any portion of which any violation of any provision of the Electrical Code is committed, continued or permitted by any such person, and he/she shall be punishable as herein provided. (Ord. 0-19-1357, 11-13-2019)
Section 7. New Article 07 Seismic Retrofit Of Unreinforced Masonry Buildings is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 07

SEISMIC RETROFIT OF UNREINFORCED MASONRY BUILDINGS
SECTION:

25.07.01: Seismic Safety Commission Draft Model Ordinance Adopted

25.07.02: Copies Available

25.07.03: Penalties

25.07.01: SEISMIC SAFETY COMMISSION DRAFT MODEL ORDINANCE ADOPTED:

The State of California Seismic Safety Commission Draft Model Ordinance, February 1990 Edition, as amended and in effect on November 1, 1990, is hereby adopted by reference as the Seismic Safety Ordinance of the City. (Ord. 984, 2-13-91)

25.07.02: COPIES AVAILABLE:

A copy of the Seismic Safety Commission Draft Model Ordinance, February 1990 Edition, has been deposited in the office of the City Clerk and shall be, at all times, maintained by the Clerk for the public's use and examination. (Ord. 984, 2-13-91)

25.07.03: PENALTIES:

Any person who shall violate any of the provisions of this Article or fail to comply therewith or who shall violate or fail to comply with any order made thereunder or who shall build in violation of any detailed statement of specifications or plans submitted and approved thereunder or any certificate or permit issued thereunder, and from which no appeal has been taken, or who shall fail to comply with such an order as affirmed or modified by the Planning Commission, City Council or by a court of competent jurisdiction within the time fixed herein shall severally, on each and every such violation and noncompliance, respectively, be guilty of a misdemeanor and shall be punishable as provided in Section 01.04.03A of this Code. (Ord. 984, 2-13-91) Section 8. New Article 08 Miscellaneous is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 08

MISCELLANEOUS
SECTION:

25.08.01: Building Relocation Permit

25.08.02: Building Mover's Permit

25.08.03: General Liability Insurance Coverage

25.08.04: Street Address Numbers

25.08.01: BUILDING RELOCATION PERMIT:

A. Permit Required: No person may relocate a building or structure, or any portion thereof, onto or within a site within City limits unless the person who owns or has legal control of the site has first obtained a building relocation permit as provided in this Section.

B. Application for Permit: An applicant for a building relocation permit shall complete and submit to the City an application package consisting of the following documents:

1. An application form completed and signed by the person who owns or has legal control of the site. The completed application shall include the name of the owner, the type of structure, the value and approximate age of the building, description of any alteration, repair work or other work, if any, to be performed on the building after relocation and any other necessary information requested by City staff.

2. A set of working drawings, electrical and mechanical plans, complete specifications and any other documents requested by City staff which show, at a minimum, site preparation, floor plans, elevations and other construction details.

3. A set of photographs, not less than five inches by seven inches (5" x 7") in dimension, of all sides of the building showing its general architectural design and appearance.

4. An application fee in an amount set by the City Council to cover the cost to the City of issuing the permit and monitoring the relocation.

C. Hearing; Notice: Upon the filing of such application, a hearing shall be set before the Planning Commission. Notice of the time and place of such hearing and the purpose thereof shall be given by the mailing of notices to the owners of all property within three hundred feet (300') of the property to which the building or structure is to be moved. Such mailing of notices shall be completed at least ten (10) days before such hearing.

D. Findings: The Planning Commission shall not grant a building relocation permit if the Planning Commission finds that the building or structure is so old, dilapidated and in such a state of disrepair as to be unsanitary or otherwise unfit for human habitation, occupancy or use or would, by reason of its external appearance, not be compatible with the neighborhood in its new location.

Before granting approval of a proposed relocation, the applicant therefor shall affirmatively show or prove, and the Commission shall so find, that all the following conditions are met:

1. The structure is in conformity with the type and quality of buildings existing in the surrounding area of the proposed site.

2. The structure will constitute a beneficial addition to and contribute to the general development of the area.

3. The proposed relocation will not conflict with any of the property development standards of this Code.

4. The structure proposed to be relocated is completely free of pest infestation as certified by a qualified pest extermination firm.

5. The proposed relocation will in no way be detrimental to persons, to properties or to the living environment of the area.

6. That the proposed relocation will not adversely affect any streets, parkway trees or other improvements in the area.

7. The proposed relocation is consistent with the General Plan of the City.

E. Commission Action: The Commission may approve, conditionally approve or deny the request for relocation based on the evidence submitted and its own study and knowledge of the circumstances.

F. Conditions of Approval: The Commission may approve a proposed relocation subject to such conditions as the Commission may deem warranted by the circumstances involved. Such conditions may include, but are not limited to, any or all of the following:

1. Dedication and improvement of streets which may include curb, gutters, sidewalk and paving.

2. A faithful performance bond guaranteeing the applicant will complete the relocation and will meet all conditions prior to occupancy. Said deposit or bond shall also be sufficient to cover the costs of all matters involving the City, such as inspections, engineering, street and other improvements, and restoration of the vacated site if located within the City.

G. Time Limits: All work will be completed within one hundred eighty (180) days after approval is granted. The Planning Commission can grant one extension of ninety (90) days if the applicant shows that circumstances beyond the control of the applicant caused the delay.

H. Permit Supplemental to Other Laws: The permit required by the provisions of this Section shall be in addition to any other permit required by any other law of the City or any governmental agency having jurisdiction.

I. Inspections: All relocated buildings or structures shall be subject to inspection by the Building and Safety Department and shall conform to all the requirements of the Building Code 1 and other codes and laws relating to buildings and construction and the necessary installations incident thereto.

J. Appeals:

1. Filing: Any person aggrieved by the decision of the Planning Commission may file an appeal to the City Council within fifteen (15) days after the date such action is taken by the Planning Commission. Such appeal shall be in writing and shall be filed with the City Clerk.

2. Review: Upon the filing of any such appeal, the City Council may either affirm the action of the Planning Commission, set the matter for a hearing de novo or request a copy of the relevant information submitted to the Planning Commission and a copy of the minutes of the Planning Commission meeting and decide the matter on the record. If a hearing de novo is held, a hearing shall be set forth before the Council. Notice of the time and place of such hearing and the purpose thereof shall be given by the mailing of notices to the owners of all property contiguous to the property to which the building or structure is to be moved. Such mailing of notices shall be completed at least ten (10) days before such hearing.

3. Determinations: If the City Council holds a hearing de novo or considers the matter on the record before the Planning Commission, the City Council shall consider the application on the standards contained in subsection D hereof.

K. Exceptions: Upon a proper showing, the City Council may modify the requirements of this Section or may waive or reduce the permit application fees where the building or structure to be moved is owned or is to be used or occupied by another public agency and is already located within the City limits or where the building or structure is so small as to not have any negative impact on surrounding properties. (Ord. 992, 7-10-91)
Notes
1 1. See Article 02 of this Chapter.

25.08.02: BUILDING MOVER'S PERMIT:

A. Permit Required: No person shall move any building or structure or any portion thereof over, upon, along or across any street without first obtaining a building mover's permit.

B. Application for Permit: The applicant shall complete and submit to the Planning and Building Department an application package consisting of the following documents:

1. An application form completed and signed by the person who intends to move the building.

The completed application shall include the name of the owner, the type of structure, its present and proposed location, the fair value and approximate age of the building, the proposed route, the method of moving, impact on parkway trees, the time within which the work of moving shall be commenced and completed, proof that all the necessary authority and permits have been obtained from the public utilities which may be affected by such moving operations and any other necessary information requested by City staff.

2. That the contractor furnish the City with a policy or certificate of liability insurance in which the City is named insured. The minimum amount shall be two hundred fifty thousand dollars ($250,000.00) of property damage insurance and of personal liability insurance with a combined single amount of no less than one million dollars ($1,000,000.00). The policies shall otherwise be prepared in accordance with the latest edition of the Standard Specifications for Public Works Construction, section 7-3.

3. An application fee in an amount to be set by the City Council, from time to time, to cover the cost to the City of issuing the permit and monitoring the relocation.

4. Evidence of workers' compensation insurance.

C. Review of Application: The City Manager, the Director of Planning and BuildingCommunity Development Director and the Director of Public Works must review and approve the application. The application may be approved subject to conditions deemed necessary.

D. Permit Revocation: After the permit is issued, the Planning and Building Department shall monitor the relocation, and if any violations of the permit conditions are found, the City Manager may revoke the permit.

E. Expiration of Permit: Every building mover's permit issued pursuant to this Section shall contain each and every term and condition imposed by the City and shall be valid for a period of ninety (90) days after which it shall expire without further notice. (Ord. 992, 7-10-91)

25.08.03: GENERAL LIABILITY INSURANCE COVERAGE:

No individual or business employing any worker or possessing a State contractor's license shall be issued a building permit or an encroachment permit by the City for any building activity valued at more than two hundred dollars ($200.00) as provided for in this Code or for the encroachment upon any public right of way without having first provided written proof of possession of current general liability insurance coverage in an amount and form to be established by the City Engineer 1 . (Ord. 911, 1-14-87)
Notes
1 1. West's Ann.Cal.Stats.Gov. Code §53080.5.

25.08.04: STREET ADDRESS NUMBERS:

Assigned street address numbers shall be placed or displayed on or near the front of each home or building facing the public street or thoroughfare on which it is located. Said numbers shall be arabic numerals at least three inches (3"4) high and of corresponding width. All numbers shall be placed in a location clearly visible from the street or thoroughfare after the person owning or occupying the premises shall have been notified by the Planning and Building DirectorCommunity Development Director of the appropriate street address numbers. If a public alley or thoroughfare abuts the rear of a commercial building, the street address numbers shall also be placed at the rear of the building in such a manner that they are visible from the public alley or thoroughfare. (Ord. 917, 5-13-87)
Section 9. New Article 09 Energy Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 09

ENERGY CODE
SECTION:

25.09.01: Energy Code Adopted

25.09.02: Violations

25.09.01: ENERGY CODE ADOPTED:

Except as hereinafter provided, the California Energy Code, 20252 Edition, as published by the California Building Standards Commission, including all appendices, is hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the Energy Code of the City. A copy of said code shall be located in the Planning and Building Department and shall be, at all times, maintained by the Planning and Building Department for use and examination by the public.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.09.02: VIOLATIONS:

Any person, firm or corporation violating any of the provisions or failing to comply with any of the mandatory requirements of this article shall be guilty of a misdemeanor and upon conviction thereof shall be punishable as provided in section 01.04.03 A of this Code. Each such person shall be guilty of a separate offense for each and every day during any portion of which any violation of any provision of this article is committed, continued or permitted by any such person, and he/she shall be punishable as herein provided.
(Ord. 0-19-1357, 11-13-2019)
Section 10. New Article 10 Administrative Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 10

ADMINISTRATIVE CODE
SECTION:

25.10.01: Administrative Code Adopted

25.10.01: ADMINISTRATIVE CODE ADOPTED:

Except as hereinafter provided, the California Administrative Code, 20252 Edition, as published by the California Building Standards Commission, is hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the Administrative Code of the City. A copy of said code shall be located in the Planning and Building Department and shall be, at all times, maintained by the Planning and Building Department for use and examination by the public.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023) Section 11. New Article 11 Floodplain Management is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 11

FLOODPLAIN MANAGEMENT
SECTION:

25.11.01: Definitions

25.11.02: Lands To Which This Article Applies

25.11.03: Basis For Establishing Flood Prone Areas

25.11.04: Compliance

25.11.05: Abrogation And Greater Restrictions

25.11.06: Interpretation

25.11.07: Warning And Disclaimer Of Liability

25.11.08: Establishment Of Development Permit

25.11.09: Duties And Responsibilities Of The Floodplain Administrator

25.11.10: Standards Of Construction

25.11.11: Standards For Subdivisions Or Other Proposed New Development

25.11.12: Standards For Utilities

25.11.01: DEFINITIONS:

Unless specifically defined in this section, words or phrases used in this article shall be interpreted so as to give them the meaning they have in common usage and to give this article its most reasonable application.

AREA OF SPECIAL FLOOD HAZARD: The land in the floodplain within a community subject to a one percent (1%) or greater chance of flooding in any given year.

BASE FLOOD: A flood which has a one percent (1%) chance of being equaled or exceeded in any given year (also called the "100-year flood"). Base flood is the term used throughout this article.

BUILDING: Any structure.

DEVELOPMENT: Any manmade change to improved or unimproved real estate, including, but not limited to, buildings or other structures, mining, dredging, filling, grading, paving, excavation or drilling operations or storage of equipment or materials.

FLOOD OR FLOODING:

A. A general and temporary condition of partial or complete inundation of normally dry land areas from: the overflow of inland or tidal waters; the unusual and rapid accumulation or runoff of surface waters from any source; or mudslides (i.e., mudflows) which are proximately caused by flooding as defined herein and are akin to a river of liquid and flowing mud on the surfaces of normally dry land areas, as when earth is carried by a current of water and deposited along the path of the current; or
B. The collapse or subsidence of land along the shore of a lake or other body of water as a result of erosion or undermining caused by waves or currents of water exceeding anticipated cyclical levels or suddenly caused by an unusual and unforeseeable event which results in flooding as defined in this definition.

FLOODPLAIN ADMINISTRATOR: The planning and building directorCommunity Development Director, who is hereby appointed to administer, implement, and enforce this article by granting or denying development permits in accord with its provisions.

FLOODPLAIN MANAGEMENT: The operation of an overall program of corrective and preventive measures for reducing flood damage and preserving and enhancing, where possible, natural resources in the floodplain, including, but not limited to, emergency preparedness plans, flood control works, floodplain management regulations, and open space plans.

FLOODPLAIN MANAGEMENT REGULATIONS: This article and all other provisions of this code that control development in flood prone areas, and any other federal, state, or local regulations or combination thereof which provide standards for preventing and reducing flood loss and damage.

FLOODPLAIN OR FLOOD PRONE AREA: Any land area susceptible to being inundated by water from flooding.

HISTORIC STRUCTURE: Any structure that is:

A. Listed individually in the National Register of Historic Places (a listing maintained by the department of the interior) or preliminarily determined by the secretary of the interior as meeting the requirements for individual listing on the national register; B. Certified or preliminarily determined by the secretary of the interior as contributing to the historical significance of a registered historic district or a district preliminarily determined by the secretary of the interior to qualify as a registered historic district; C. Individually listed on a state inventory of historic places in states with historic preservation programs which have been approved by the secretary of the interior; or D. Individually listed on a local inventory of historic places in communities with historic preservation programs that have been certified either by an approved state program as determined by the secretary of the interior or directly by the secretary of the interior in states with approved programs.

NEW CONSTRUCTION: For floodplain management purposes, means structures for which the "start of construction" commenced on or after the effective date of floodplain management regulations adopted by this community, and includes any subsequent improvements to such structures.
100-YEAR FLOOD: See definition of Base Flood.

START OF CONSTRUCTION: Includes substantial improvement and other proposed new development and means the date the building permit was issued, provided the actual start of construction, repair, reconstruction, rehabilitation, addition, placement, or other improvement was within one hundred eighty (180) days from the date of the permit. The "actual start" means either the first placement of permanent construction of a structure on a site, such as the pouring of slab or footings, the installation of piles, the construction of columns, or any work beyond the stage of excavation. Permanent construction does not include land preparation, such as clearing, grading, and filling; nor does it include the installation of streets and/or walkways; nor does it include excavation for a basement, footings, piers, or foundations or the erection of temporary forms; nor does it include the installation on the property of accessory buildings, such as garages or sheds not occupied as dwelling units or not part of the main structure. For a substantial improvement, the "actual start of construction" means the first alteration of any wall, ceiling, floor, or other structural part of a building, whether or not that alteration affects the external dimensions of the building.

STRUCTURE: A walled and roofed building that is principally aboveground, or a gas or liquid storage tank.

SUBSTANTIAL DAMAGE: Damage of any origin sustained by a structure whereby the cost of restoring the structure to its before damaged condition would equal or exceed fifty percent (50%) of the market value of the structure before the damage occurred.

SUBSTANTIAL IMPROVEMENT: Any reconstruction, rehabilitation, addition, or other proposed new development of a structure, the cost of which equals or exceeds fifty percent (50%) of the market value of the structure before the "start of construction" of the improvement. This term includes structures which have incurred "substantial damage", regardless of the actual repair work performed. The term does not, however, include either:

A. Any project for improvement of a structure to correct existing violations of state or local health, sanitary, or safety code specifications which have been identified by the local code enforcement official and which are the minimum necessary to assure safe living conditions; or B. Any alteration of a "historic structure", provided that the alteration will not preclude the structure's continued designation as a "historic structure". (Ord. 0-06-1185, 7-12-2006)

25.11.02: LANDS TO WHICH THIS ARTICLE APPLIES:

This article shall apply to all areas identified as flood prone within the jurisdiction of the city of San Marino. (Ord. 0-06-1185, 7-12-2006)

25.11.03: BASIS FOR ESTABLISHING FLOOD PRONE AREAS:

The floodplain administrator shall obtain, review, and reasonably utilize any base flood data available from other federal or state agencies or other source to identify flood prone areas within the jurisdiction of the city of San Marino. This data will be on file at city hall, 2200 Huntington Drive, San Marino, California. (Ord. 0-06-1185, 7-12-2006)

25.11.04: COMPLIANCE:

No structure or land shall hereafter be constructed, located, extended, converted, or altered without full compliance with the terms of this article and other applicable regulations. Violation of the requirements of this article or any conditions and safeguards imposed pursuant to this article shall constitute a misdemeanor. Nothing herein shall prevent the city council from taking such lawful action as is necessary to prevent or remedy any violation of this article. (Ord. 0-06-1185, 7-12- 2006)

25.11.05: ABROGATION AND GREATER RESTRICTIONS:

This article is not intended to repeal, abrogate, or impair any existing easements, covenants, or deed restrictions. However, where this article and another ordinance, easement, covenant, or deed restriction conflict or overlap, whichever imposes the more stringent restriction shall prevail. (Ord. 0-06-1185, 7-12-2006)

25.11.06: INTERPRETATION:

In the interpretation and application of this article, all provisions shall be:

A. Considered as minimum requirements;
B. Liberally construed in favor of the city; and
C. Deemed neither to limit nor repeal any other powers granted under state statutes. (Ord. 0- 06-1185, 7-12-2006)

25.11.07: WARNING AND DISCLAIMER OF LIABILITY:

The degree of flood protection required by this article is considered reasonable for regulatory purposes and is based on scientific and engineering considerations. Larger floods can and will occur on rare occasions. Flood heights may be increased by manmade or natural causes. This article does not imply that land outside the areas of special flood hazards or uses permitted within such areas will be free from flooding or flood damages. This article shall not make the city of San Marino, the city council, or any officer or employee of the city, the state of California, or the federal insurance administration, federal emergency management agency, liable for any flood damages that result from reliance on this article or any administrative decision lawfully made hereunder. (Ord. 0-06-1185, 7-12-2006)

25.11.08: ESTABLISHMENT OF DEVELOPMENT PERMIT:

A development permit shall be obtained for all proposed construction or other development so that it may be determined whether such construction or other development is within flood prone areas. (Ord. 0-06-1185, 7-12-2006)

25.11.09: DUTIES AND RESPONSIBILITIES OF THE FLOODPLAIN ADMINISTRATOR:

The duties and responsibilities of the floodplain administrator shall include, but not be limited to, the following:

A. Permit Review: Review all development permit applications to determine whether:

1. The requirements of this article have been satisfied;

2. All other required state and federal permits have been obtained; and

3. The site is reasonably safe from flooding.

B. Review And Use Of Any Other Base Flood Data: The floodplain administrator shall obtain, review, and reasonably utilize any base flood data available from other federal or state agency or other source. (Ord. 0-06-1185, 7-12-2006)

25.11.10: STANDARDS OF CONSTRUCTION:

If a proposed building site is in a flood prone area, all new construction and substantial improvements shall:

A. Be designed (or modified) and adequately anchored to prevent flotation, collapse, or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy.

B. Be constructed:

1. With materials and utility equipment resistant to flood damage;

2. Using methods and practices that minimize flood damage;

3. With electrical, heating, ventilation, plumbing and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding. (Ord. 0-06-1185, 7-12-2006)

25.11.11: STANDARDS FOR SUBDIVISIONS OR OTHER PROPOSED NEW DEVELOPMENT:

Any application for a subdivision or parcel map or for any other development in a flood prone area shall be reviewed to assure that:

A. The development project is consistent with the need to minimize flood damage within the flood prone area;
B. All public utilities and facilities such as sewer, gas, electrical, and water systems are located and constructed to minimize or eliminate flood damage; and C. Adequate drainage is provided to reduce exposure to flood hazards. (Ord. 0-06-1185, 7-12- 2006)

25.11.12: STANDARDS FOR UTILITIES:

A. All new and replacement water supply and sanitary sewage systems shall be designed to minimize or eliminate:

1. Infiltration of floodwaters into the systems, and

2. Discharge from the systems into floodwaters.

B. On site waste disposal systems shall be located to avoid impairment to them, or contamination from them during flooding. (Ord. 0-06-1185, 7-12-2006) Section 12. New Article 12 Fire Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 12

FIRE CODE
SECTION:

25.12.01 Fire Code Adopted

25.12.02 Amendment of Section 107.2108.2

25.12.03 Addition of Section 107.2.3108.2.3

25.12.04 Deletion of Section 111.1 112.1 and Addition of Section 111.5112.5

25.12.05 Amendment of Section 112.4113.4

25.12.06 Addition of Section 304.1.2.1

25.12.0607 Addition of Section 307.6

25.12.0708 Addition of Section 308.1.4.1

25.12.0809 Addition of Section 506.1.3

25.12.0910 Amendment of Section 903.2

25.12.1011 Amendment of Section 903.2.8.1

25.12.1112 Amendment of Section 903.2.18

25.12.1213 Addition of Section 903.3.1.3.1

25.12.1314 Amendment of Section 903.4.1

25.12.1415 Addition of Section 906.1.1

25.12.1516 Addition of Section 907.2.A

25.12.17 Amendment of Section 907.2.9.1

25.12.1618 Deletion of Section 907.6.6, Exception 3

25.12.1719 Amendment of Section 912.2

25.12.18 20 Amendment of Section 3103.2

25.12.19 Addition of Section 4907.4

25.12.2021 Addition of Section 5608.2

25.12.01: FIRE CODE ADOPTED: Except as hereinafter provided, the 2022 2025 California Fire Code, including all appendices with errata, based on the 2021 2024 International Fire Code, is hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the Fire Code of the City. A copy of such code shall be located in the Planning and Building Department and shall be, at all times, maintained by the Planning and Building Department for use and examination by the public. For the purpose of this Code, the Planning and Building DirectorCommunity Development Director shall be the building official.

25.12.02: AMENDMENT OF SECTION 107.2108.2: Notwithstanding the provisions of Section

25.12.01 of this article, Section 107.2108.2 of the Fire Code is hereby amended to read as follows:
107.2108.2 Establishment of Fees. All fees pursuant to the fire code shall be established by resolution of the city council.

25.12.03: ADDITION OF SECTION 107.2.3108.2.3: Notwithstanding the provisions of Section

25.12.01 of this article, Section 107.2.3108.2.3 is added to the Fire Code to read as follows:
107.2.3108.2.3 Annual Inspection Required. All properties located in the high fire hazard severity zone as identified by the San Marino Fire Department shall be inspected as deemed necessary for compliance with state and local brush clearance requirements in Section

12.12.1912.12.06 by the fire official.

25.12.04: DELETION OF SECTION 111.1112.1 AND ADDITION OF SECTION 111.5112.5: Notwithstanding the provisions of section 25.12.01 of this article, Section 111.1 of the Fire Code is deleted and Section 111.5112.5 is added to the Fire Code to read as follows:
111.5112.5 Appeals. Whenever the fire chief disapproves an application or refuses to grant a permit applied for, or when it is claimed that the provisions of the fire code do not apply or that the true intent and meaning of the fire code have been misconstrued or wrongly interpreted, the applicant may appeal the fire chief's decision to the city manager within thirty (30) days from the date of the decision. If the city manager upholds the decision of the fire chief, the applicant may appeal the decision to the city council by filing a notice of appeal with the city clerk within ten (10) days from the date of the city manager's decision.

25.12.05: AMENDMENT OF SECTION 112.4113.4: Notwithstanding the provisions of Section

25.12.01 of this article, Section 112.4113.4 of the Fire Code is amended to read as follows:
112.4113.4 Violation Penalties. Persons who shall violate a provision of this code or shall fail to comply with any of the requirements thereof or who shall erect, install, alter, repair, or do work in violation of the approved construction document or directive of the fire code official, or of a permit or certificate used under provisions of this code, shall be guilty of a misdemeanor, punishable by a fine as established by the city council or by imprisonment, or both such fine and imprisonment.

Each day that a violation continues after due notice has been served shall be deemed a separate offense. The imposition of one penalty for any violation shall not excuse the violation or permit it to continue; and all such persons shall be required to correct or remedy such violations or defects in a timely manner as specified by the chief or authorized representative. The application of the above penalties shall not be held to prevent the enforced removal of prohibited conditions.

25.12.1925.12.06: ADDITION OF SECTION 4907.4304.1.2.1: Notwithstanding the provisions of Section 25.12.01 of this article, Section 4908304.1.2.1 is added to the Fire Code to read as follows:

Section 4907.4 304.1.2.1 Clearance of Hazardous Vegetation from Structures and Roads within the City of San Marino.
4907.4.1304.1.2.1.1 Statement of Legislative Intent and Purpose. It is the objective of this section to promote and protect the public health, safety and welfare by recognizing that there exists within the city of San Marino a potentially hazardous fire situation created by grass, weeds, shrubs, and trees which are in such condition and location as to provide a ready fuel supply to augment the spread or intensity of fire. It is the intent of this section to provide minimum standards to safeguard life, safety, property and the public welfare by insuring that hazardous vegetation or refuse is removed and that all grass, weeds, shrubs, and trees are properly maintained so as to not create a fire hazard within the community, while maintaining sufficient vegetation for aesthetic and soil erosion control purposes.

It is the further intent that this section apply on a year-round basis to insure the removal and/or proper maintenance of grass, weeds, shrubs, trees and refuse in order to prevent the spread or intensity of fire within the community. Of particular concern is the need to provide adequate defensible space in the urban/wildland interface area of the city, referred to as the high fire hazard severity zone. For purposes of this section, defensible space is that space within 100 feet (30.480 m) of a building or structure that is required for access by fire and other emergency personnel to defend the building or structure from the threat of fire. 4907.4.2 304.1.2.1.2 Prohibition. No person who has any ownership or possessory interest in, or control of a parcel of land shall allow to exist thereon any hazardous refuse or hazardous grass, weeds, shrubs, trees, or other vegetation, which, by reason of proximity to a building or structure, constitutes a fire hazard. For purposes of this section, hazardous grass, weeds, shrubs, trees, or other vegetation are defined as grass, weeds, shrubs, trees, or other vegetation which are in such condition and location, or by the unique characteristics of a species, as to provide a ready fuel supply to augment the spread or intensity of a fire.
4907.4.3.1304.1.2.1.3 Specific Requirements. In order to provide sufficient defensible space, each person who has any ownership or possessory interest in, or control of, a parcel of land shall:
4907.4.3.1304.1.2.1.3.1 General. Remove from the property all hazardous vegetation, except as otherwise provided herein, if such vegetation is within 100 feet (30.480 m) of a building, within ten (10) feet (3.048 m) of a combustible fence, or within ten (10) feet (3.048 m) of any portion of any highway, street, alley, or driveway improved or used for vehicular travel or other vehicular purposes. Distances up to 200 feet (60.960 m) or greater from a building or structure may be necessary as determined by the chief. This requirement does not apply to the maintenance of trees, ornamental shrubbery or plants which are used as ground cover, provided such are landscape materials that are properly irrigated and maintained and do not provide a ready fuel supply to augment the spread or intensity of a fire.
4907.4.3.2 304.1.2.1.3.2 Adjacent To Building. Keep all trees, shrubs, and other vegetation or portions thereof, adjacent to or overhanging any building or structure free of dead limbs, branches, and other combustible matter.
4907.4.3.3 304.1.2.1.3.3 Roof Clearance. Maintain 5 feet (1.524 m) of vertical clearance between roof surfaces and portions of trees or shrubs overhanging any building or structure. 4907.4.3.4 304.1.2.1.3.4 Chimney Clearance. Remove any portion of a tree or shrub which extends within 15 feet (4.572 m) of the outlet of a chimney or stovepipe. 4907.4.3.5 304.1.2.1.3.5 Roof Surface. Maintain the roofs of all buildings or structures free of leaves, needles, twigs, and other combustible matter.
4907.4.3.6 304.1.2.1.3.6 Building Clearance--30 Feet. Maintain all hazardous grass, weeds, and small shrubs within 30 feet (9.144 m) of any building or structure. Hazardous vegetation must be maintained less than 3 inches (76 mm) high; cut grass may be left on the slope to protect the soil if it lays down within 3 inches (76 mm) of the ground. Large native shrubs may be retained no closer than an average of 18 feet (5.486 m) apart, provided the lower branches have been trimmed a minimum of 3 feet (914 mm) above the ground, or at least thinned to reduce the available fuel volume.
4907.4.3.7 304.1.2.1.3.7 Roads. Maintain trees and shrubs within 10 feet of that portion of any highway, street, alley, or driveway which is improved or used for vehicle travel or other vehicular purposes (except for designated fire roads), so that no leafy foliage, twigs, or branches are within six (6) feet (1.828 m) of the ground (but no more than 1/3 of the crown). 4907.4.3.8 304.1.2.1.3.8 Combustible Fences. Maintain all hazardous grass, weeds and other vegetation located within 10 feet (3.048 m) of any combustible fence at a height of not more than 3 inches (76 mm). This shall not require the removal of trees, ornamental shrubbery or plants which are used as ground cover, provided such do not provide a ready fuel supply to augment the spread or intensity of a fire.
4907.4.3.9304.1.2.1.3.9 Building Clearance--100 Feet. Maintain all hazardous grass, weeds, shrubs and trees within 100 feet (30.480 m) of any building or structure. Grass and small shrubs may be retained on steep slopes to stabilize the soil and prevent erosion, but may not exceed a height of 18 inches (457 mm). Large native specimen shrubs should be retained where possible, but no closer than an average of 18 feet (5.486 m) apart. Remove all dead foliage, twigs or branches, or live branches within 3 feet (914 mm) of the ground, from mature trees and shrubs (but no more than 1/3 of the crown).
4907.4.3.10 304.1.2.1.3.10 Cut Vegetation and Refuse. Remove and/or safely dispose of all cut vegetation and hazardous refuse.
4907.4.3.11304.1.2.1.3.11 Soil Erosion Control. If the abatement of hazardous vegetation results in the exposure of bare mineral soil, or the soil is exposed to such an extent that increased soil erosion would be likely, or the chief or his designee determines that the abatement has been excessive and poses a threat to the public health, safety or welfare, irrigation and landscaping or a suitable erosion control structure must be provided to establish effective soil erosion control. 4907.4.3.12 304.1.2.1.3.12 Minimum Requirements. Nothing contained in this section shall be deemed to preclude the chief from requiring more than the minimum specific requirements set forth above when the chief determines that conditions exist which necessitate greater fire protection measures.
4907.5 304.1.2.1.5 Notice. The council finds that grass, weeds, shrubs, trees, or other vegetation prohibited under sec. 4908.3 increase the danger of fire and thus constitute a public nuisance. If such condition exists, the San Marino Fire Department shall give notice to the owner of record to abate the nuisance within 30 days. The notice shall state that the owner is required to abate the nuisance and that if the nuisance is not abated the city may take further action which can include, (1) the city, or its contractor, may enter upon the parcel of land and remove or otherwise eliminate or abate the nuisance, (2) that upon completion of such work the cost thereof, including administrative costs, shall become a special assessment against that parcel, and (3) that upon council confirmation of the assessment and recordation of that order, a lien shall attach to the parcel to be collected on the next regular property tax bill levied against the parcel.”

25.12.0625.12.07: ADDITION OF SECTION 307.6: Notwithstanding the provisions of Section

25.12.01 of this article, Section 307.6 is added to the Fire Code to read as follows:
307.6 Outdoor Fireplaces, Fire Pits, And Decorative Fire Features. Outdoor fireplaces, fire pits, and decorative fire features shall be installed and used in accordance with the manufacturer's instructions. Outdoor fireplaces, fire pits, and decorative fire features, as identified under this code section, shall be listed electric and/or gas fuel-fired.

25.12.0725.12.08: ADDITION OF SECTION 308.1.4.1: Notwithstanding the provisions of Section 25.12.01 of this article, Section 308.1.4.1 is added to the Fire Code to read as follows:
308.1.4.1 Open-Flame Cooking Devices. Solid fuel, gas fuel-fired barbeques and other openflame cooking devices shall be installed and used in accordance with the manufacturer's instructions. In the absence of manufacturer's instructions, the fire chief or designee has the ability to determine proper installation location clearances and area of operation.

25.12.0825.12.09: ADDITION OF SECTION 506.1.3: Notwithstanding the provisions of Section 25.12.01 of this article, Section 506.1.3 is added to the Fire Code to read as follows:
506.1.3 Key Boxes and Switches. An approved key box or switch shall be installed on all commercial properties and all residential properties where the street access to the site is gated.

25.12.0925.12.10: AMENDMENT OF SECTION 903.2: Notwithstanding the provisions of Section 25.12.01 of this article, Section 903.2 of the Fire Code is amended to read as follows:
903.2 Where Required – All Buildings Except R-3 and U Occupancies. a. An automatic fire sprinkler system shall be installed in every new building in the city, hereinafter constructed or moved into the city, regardless of an area separation or type of construction.

Exceptions:

1. New buildings less than 720 square feet may be exempt with the concurrence of the fire chief and building official.
b. Building Additions - An automatic fire sprinkler system shall be installed in the entire building when the addition, renovation, repair and/or remodeling of any existing building, when the value thereof exceeds more than fifty percent (50%) of the market value of the existing building. All such additions, renovations, repair or remodeling performed fewer than five (5) years prior to the effective date of this section shall be considered in determining the cumulative value under this section. The value of the proposed construction and of the existing building shall be determined by the building official based upon the latest edition of the "building valuation data" as published by the International Code Council (ICC).
c. Installation, approval and maintenance of automatic fire sprinkler systems shall be in compliance with the National Fire Protection Association Standards and the California Fire Code, as adopted and amended by the City. (Reference the California Fire Code chapter 80 for other adopted standards and California amendments).
d. Automatic fire and fire sprinkler systems shall be installed and maintained at the owner's expense.
e. If the fire chief and the building official determine access for fire apparatus and equipment to any building or structure, not otherwise required hereunder to install and maintain an automatic fire sprinkler system is unduly difficult, installation of an automatic fire-extinguishing system acceptable to the chief shall be required.

25.12.1025.12.11: AMENDMENT OF SECTION 903.2.8.1: Notwithstanding the provisions of Section 25.12.01 of this article, Section 903.2.8.1 of the Fire Code is amended to read as follows:
903.2.8.1 Group R-3.
a. A fire sprinkler system shall be installed in all new buildings in the City hereinafter constructed or moved into the City.

Exceptions:

1. R-3 Occupancy Accessory Dwelling Units (ADU’s) as defined by the Government Code Section 65852.2 shall not be required to install fire sprinklers, (pursuant to AB229 and/or SB 1069) when the existing main residence is not equipped with fire sprinklers and is not required to be equipped with automatic fire sprinklers. ADU’s greater than 1,200 square feet will require fire sprinklers.

2. New buildings less than 720 square feet may be exempted with the concurrence of the fire chief and building official.
b. Existing one- and two-family dwellings shall be required to install an automatic fire sprinkler system in the existing and new portions of the building when greater than 720 square feet is added or when additions, alterations, repairs, remodels or the combination thereof exceeds 40% of the existing square footage used for human occupancy. c. Installation, approval and maintenance of automatic fire sprinkler systems shall be in compliance with the National Fire Protection Association Standards and the California Fire Code, as adopted and amended by the City. (Reference the California Fire Code chapter 80 for other adopted standards and California amendments).
d. Automatic fire-extinguishing and fire sprinkler systems shall be installed and maintained at the owner's expense.
e. If the fire chief and the building official determine access for fire apparatus and equipment to any building or structure, not otherwise required hereunder to install and maintain an automatic fire sprinkler system is unduly difficult, installation of an automatic fire-extinguishing system acceptable to the chief shall be required.

25.12.1125.12.12: AMENDMENT OF SECTION 903.2.18: Notwithstanding the provisions of Section 25.12.01 of this article, Section 903.2.18 of the Fire Code is amended to read as follows:
903.2.18 Group U – Private Garages, Carports, Enclosed Patios and Storage Rooms. An automatic fire sprinkler system shall be installed in "U" occupancy whenever:
a. Any portion of said "U" occupancy is located beneath any portion of a building used for human occupancy.
b. The ceiling of said "U" occupancy is located fewer than seven (7) feet above the adjacent grade.
c. The "U" occupancy is located closer than 15' to an adjacent building on the same property used for human occupancy that is required to be equipped with fire sprinklers.

25.12.1225.12.13: ADDITION OF SECTION 903.3.1.3.1: Notwithstanding the provisions of Section 25.12.01 of this article, Section 903.3.1.3.1 is added to the Fire Code to read as follows:
903.3.1.3.1 NFPA 13D Fire Sprinkler System Design and Installation Specifications. The following additional features and/or devices shall be incorporated into the design and installation of fire sprinkler systems in R-3/U occupancies designed per NFPA 13D and the California Fire Code Amendments.

1. A listed water flow switch with a delay feature

2. A 6” exterior bell

3. Spare sprinklers, one of each type as installed in the systems must be placed in the spare head box. The spare head box must be attached to the interior of the building.

4. Special tools as required to remove any head in the system

5. A single check valve. The water district may require additional backflow preventors.

6. The design must include 5 gpm allowance for the domestic demand.

7. The design of a hydraulically calculated fire sprinkler system shall not exceed 90% of the available water supply capacity.

8. Attics used for storage and attics equipped with fuel-burning appliances must be equipped with a “pilot” sprinkler head above the equipment and/or storage.

9. A water gauge above the check valve

10. An inspectors test valve

11. Sprinklers shall be installed in any closet that contains heating and/or air conditioning equipment, a washer, a dryer and/or a water heater regardless if the equipment is electric or gas fired.

12. An “in the bucket” acceptance test must be performed flowing water in the most hydraulically demanding areas for one minute into a factory graduated container with the capacity of the anticipated flow. The discharge must flow through the orifice of the heads as installed in the compartment. The test must be conducted by the installing contractor in the presence of the fire chief or his appointee during the rough or final inspections.

13. A 200 psi hydrostatic test must be performed for two hours during the rough piping inspection. The system must be pressurized at least one hour before the scheduled time of the inspection.

14. All NFPA 13D systems must be “Looped Passive Purge Sprinkler Systems” or a listed and acceptable Back-Flow Preventer device must be installed to protect the public water supply system.

13.15. All piping materials installed in NFPA 13D sprinkler systems must be certified as meeting NSF/ANSI Standard 61.

25.12.1325.12.14: AMENDMENT OF SECTION 903.4.1: Notwithstanding the provisions of Section 25.12.01 of this article, Section 903.4.1 of the Fire Code is amended to read as follows:
903.4.1 All automatic sprinkler systems including those protecting single-family dwellings shall have the flow switch electrically supervised by a listed central station. Alarm, supervisory and trouble signals shall be distinctly different.

Exception: R3 Dwellings and their Accessory buildings equipped with NFPA 13D Sprinkler systems and a Household Fire Alarms System are permitted to be monitored by Remote Supervising Station, unless otherwise required by the fire chief.

25.12.1425.12.15: ADDITION OF SECTION 906.1.1: Notwithstanding the provisions of Section 25.12.01 of this article, Section 906.1.1 is added to the Fire Code to read as follows:
906.1.1 Minimum Requirement. Portable fire extinguishers of a 2A10BC type shall be installed in all occupancies and locations as set forth in the fire code and as required by the fire chief.

Exceptions:

1. Other portable fire extinguishers may be installed, if approved by the fire chief or designee.

3. Group R, division 3 and group U occupancies are exempt.

25.12.1525.12.16: ADDITION OF SECTION 907.2.A Notwithstanding the provisions of Section 25.12.01 of this article, Section 907.2.A is added to the Fire Code to read as follows:
907.2.A Household Fire Alarm Required. A monitored household fire alarm system is required in all new single-family residences and accessory dwelling units that are being required to be equipped with a sprinkler system.

This required household fire alarm system is in addition of the single station smoke and carbon monoxide alarms required by the California Residential Code. The household fire alarm system shall be designed and installed in accordance with the National Fire Protection Association Standard 72. The devices installed as components of the household fire alarm system shall be installed in the following prescriptive manner:

1. A minimum of one photoelectric smoke detector on each level of living space.

2. Photoelectric smoke detectors in the hallways outside all sleeping areas.

3. A rate of rise heat detector in each accessible attic, kitchen, wok room, basements and in all “U” occupancies that are located closer than 15' to an adjacent building on the same property used for human occupancy.

4. A combination fire/security panel is permitted in R-3 and/or U occupancies. The fire alarm plans must account for the current draw of all devices in the battery calculations.

5. The household fire alarm system shall be designed to provide a local and remote signal with the following specific information for each fire alarm detection device:

1. Room and floor location.

2. Type of signal.

3. Type of device.

4. Zone identification number.

6. A minimum of one horn to sound an interior distinct fire alarm. Additional horns may be required.

7. The owner of the premises is required to maintain and have the fire alarm system supervised for the perpetuity of the building regardless if occupied.

25.12.17: AMENDMENT OF SECTION 907.2.9.1: Notwithstanding the provision of section 25.12.01 of this article, section 907.2.9.1 is amended to read as follows:
907.2.9.1 Automatic Fire Alarm System. An automatic fire alarm system that activates the occupant notification circuit in accordance with section 907.5 shall be installed in all Group R-2 occupancies, the system shall be addressable with prescriptive initiation devices.

25.12.1625.12.18: DELETION OF SECTION 907.6.6, EXCEPTION 3: Notwithstanding the provisions of Section 25.12.01 of this article, Section 907.6.6, Exception 3, of the Fire Code is deleted.

25.12.1725.12.19: AMENDMENT OF SECTION 912.2: Notwithstanding the provisions of Section 25.12.01 of this article, Section 912.2 is amended to read as follows:
912.2 Fire Department connections shall be located within 150 feet of a public fire hydrant; the Fire Department connection and the fire hydrant must be located on the same side of the street of a divided road, unless otherwise approved by the fire chief.

25.12.1825.12.20: AMENDMENT OF SECTION 3103.2: Notwithstanding the provisions of Section 25.12.01 of this article, Section 3103.2 of the Fire Code is amended to read as follows:
3103.2 Approval Required. Tents and membrane structures having an area in excess of 250 square feet, shall not be erected, operated or maintained for any purpose without first obtaining a permit and approval from the fire chief.

Exceptions:

1. Tents used exclusively for recreational camping purposes.

25.12.19: ADDITION OF SECTION 4907.4: Notwithstanding the provisions of Section

25.12.01 of this article, Section 4908 is added to the Fire Code to read as follows:

Section 4907.4 Clearance of Hazardous Vegetation from Structures and Roads within the City of San Marino.
4907.4.1 Statement of Legislative Intent and Purpose. It is the objective of this section to promote and protect the public health, safety and welfare by recognizing that there exists within the city of San Marino a potentially hazardous fire situation created by grass, weeds, shrubs, and trees which are in such condition and location as to provide a ready fuel supply to augment the spread or intensity of fire. It is the intent of this section to provide minimum standards to safeguard life, safety, property and the public welfare by insuring that hazardous vegetation or refuse is removed and that all grass, weeds, shrubs, and trees are properly maintained so as to not create a fire hazard within the community, while maintaining sufficient vegetation for aesthetic and soil erosion control purposes.

It is the further intent that this section apply on a year-round basis to insure the removal and/or proper maintenance of grass, weeds, shrubs, trees and refuse in order to prevent the spread or intensity of fire within the community. Of particular concern is the need to provide adequate defensible space in the urban/wildland interface area of the city, referred to as the high fire hazard severity zone. For purposes of this section, defensible space is that space within 100 feet (30.480 m) of a building or structure that is required for access by fire and other emergency personnel to defend the building or structure from the threat of fire. 4907.4.2 Prohibition. No person who has any ownership or possessory interest in, or control of a parcel of land shall allow to exist thereon any hazardous refuse or hazardous grass, weeds, shrubs, trees, or other vegetation, which, by reason of proximity to a building or structure, constitutes a fire hazard. For purposes of this section, hazardous grass, weeds, shrubs, trees, or other vegetation are defined as grass, weeds, shrubs, trees, or other vegetation which are in such condition and location, or by the unique characteristics of a species, as to provide a ready fuel supply to augment the spread or intensity of a fire.
4907.4.3 Specific Requirements. In order to provide sufficient defensible space, each person who has any ownership or possessory interest in, or control of, a parcel of land shall:
4907.4.3.1 General. Remove from the property all hazardous vegetation, except as otherwise provided herein, if such vegetation is within 100 feet (30.480 m) of a building, within ten (10) feet (3.048 m) of a combustible fence, or within ten (10) feet (3.048 m) of any portion of any highway, street, alley, or driveway improved or used for vehicular travel or other vehicular purposes. Distances up to 200 feet (60.960 m) or greater from a building or structure may be necessary as determined by the chief. This requirement does not apply to the maintenance of trees, ornamental shrubbery or plants which are used as ground cover, provided such are landscape materials that are properly irrigated and maintained and do not provide a ready fuel supply to augment the spread or intensity of a fire.
4907.4.3.2 Adjacent To Building. Keep all trees, shrubs, and other vegetation or portions thereof, adjacent to or overhanging any building or structure free of dead limbs, branches, and other combustible matter.
4907.4.3.3 Roof Clearance. Maintain 5 feet (1.524 m) of vertical clearance between roof surfaces and portions of trees or shrubs overhanging any building or structure. 4907.4.3.4 Chimney Clearance. Remove any portion of a tree or shrub which extends within 15 feet (4.572 m) of the outlet of a chimney or stovepipe. 4907.4.3.5 Roof Surface. Maintain the roofs of all buildings or structures free of leaves, needles, twigs, and other combustible matter.
4907.4.3.6 Building Clearance--30 Feet. Maintain all hazardous grass, weeds, and small shrubs within 30 feet (9.144 m) of any building or structure. Hazardous vegetation must be maintained less than 3 inches (76 mm) high; cut grass may be left on the slope to protect the soil if it lays down within 3 inches (76 mm) of the ground. Large native shrubs may be retained no closer than an average of 18 feet (5.486 m) apart, provided the lower branches have been trimmed a minimum of 3 feet (914 mm) above the ground, or at least thinned to reduce the available fuel volume.
4907.4.3.7 Roads. Maintain trees and shrubs within 10 feet of that portion of any highway, street, alley, or driveway which is improved or used for vehicle travel or other vehicular purposes (except for designated fire roads), so that no leafy foliage, twigs, or branches are within six (6) feet (1.828 m) of the ground (but no more than 1/3 of the crown). 4907.4.3.8 Combustible Fences. Maintain all hazardous grass, weeds and other vegetation located within 10 feet (3.048 m) of any combustible fence at a height of not more than 3 inches (76 mm). This shall not require the removal of trees, ornamental shrubbery or plants which are used as ground cover, provided such do not provide a ready fuel supply to augment the spread or intensity of a fire.
4907.4.3.9 Building Clearance--100 Feet. Maintain all hazardous grass, weeds, shrubs and trees within 100 feet (30.480 m) of any building or structure. Grass and small shrubs may be retained on steep slopes to stabilize the soil and prevent erosion, but may not exceed a height of 18 inches (457 mm). Large native specimen shrubs should be retained where possible, but no closer than an average of 18 feet (5.486 m) apart. Remove all dead foliage, twigs or branches, or live branches within 3 feet (914 mm) of the ground, from mature trees and shrubs (but no more than 1/3 of the crown).
4907.4.3.10 Cut Vegetation and Refuse. Remove and/or safely dispose of all cut vegetation and hazardous refuse.
4907.4.3.11 Soil Erosion Control. If the abatement of hazardous vegetation results in the exposure of bare mineral soil, or the soil is exposed to such an extent that increased soil erosion would be likely, or the chief or his designee determines that the abatement has been excessive and poses a threat to the public health, safety or welfare, irrigation and landscaping or a suitable erosion control structure must be provided to establish effective soil erosion control. 4907.4.3.12 Minimum Requirements. Nothing contained in this section shall be deemed to preclude the chief from requiring more than the minimum specific requirements set forth above when the chief determines that conditions exist which necessitate greater fire protection measures. 4907.5 Notice. The council finds that grass, weeds, shrubs, trees, or other vegetation prohibited under sec. 4908.3 increase the danger of fire and thus constitute a public nuisance. If such condition exists, the San Marino Fire Department shall give notice to the owner of record to abate the nuisance within 30 days. The notice shall state that the owner is required to abate the nuisance and that if the nuisance is not abated the city may take further action which can include, (1) the city, or its contractor, may enter upon the parcel of land and remove or otherwise eliminate or abate the nuisance, (2) that upon completion of such work the cost thereof, including administrative costs, shall become a special assessment against that parcel, and (3) that upon council confirmation of the assessment and recordation of that order, a lien shall attach to the parcel to be collected on the next regular property tax bill levied against the parcel.”

25.12.2025.12.21: ADDITION OF SECTION 5608.2: Notwithstanding the provisions of Section

25.12.01 of this article, Section 5608.2 is added to the Fire Code to read as follows:
5608.2 The manufacturing, possession, storage, sale, use and handling of fireworks, other than "safe and sane" fireworks, is prohibited. The display, use or sale of fireworks described as "safe and sane" by the state fire marshal, is prohibited.

Exceptions:

1. Storage of fireworks is allowed in accordance with the requirements for low order explosives in title 19, California code of regulations, chapter 10.

2. Use and handling of fireworks for professional display by a state licensed pyrotechnician in accordance with title 19, California code of regulations, chapter 6, if permitted by the fire chief.

Section 13. New Article 13 Green Building Standards Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 13

GREEN BUILDING STANDARDS CODE
SECTION:

25.13.01: Green Building Standards Code Adopted

25.13.02: Addition Of Section 101.12

25.13.03: Amendment Of Section 202

25.13.04: Amendment Of Section 301.1

25.13.05: Amendment Of Section 301.1.1

25.13.06: Amendment Of Section 5.408.3

25.13.07: Amendment Of Section 601.1

25.13.08: Violations

25.13.01: GREEN BUILDING STANDARDS CODE ADOPTED:

Except as hereinafter provided, the mandatory measures of the California Green Building Standards Code, 20252 Edition, as published by the California Building Standards Commission, are hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the Green Building Standards Code of the City. A copy of said code shall be located in the Planning and Building Department and shall be, at all times, maintained by the Planning and Building Department for use and examination by the public. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023)

25.13.02: ADDITION OF SECTION 101.12:

Notwithstanding the provisions of section 25.13.01 of this article, section 101.12 is added to the Green Building Standards Code to read as follows.
101.12 Fee for Mandatory Measures. The fee for each plan check/permit shall be as periodically established by City Council resolution.
(Ord. 0-19-1357, 11-13-2019)

25.13.03: AMENDMENT OF SECTION 202:

Notwithstanding the provisions of section 25.13.01 of this article, section 202 of the Green Building Standards Code is amended by adding a definition to read as follows:

SUSTAINABILITY. Consideration of present development and construction impacts on the community, the economy, and the environment without compromising the needs of the future. (Ord. 0-19-1357, 11-13-2019)

25.13.04: AMENDMENT OF SECTION 301.1:

Notwithstanding the provisions of section 25.13.01 of this article, section 301.1 of the Green Building Standards Code is amended to read as follows:
301.1 Scope. Buildings shall be designed to include the green building measures specified as mandatory this code. Voluntary green building measures are also included in this code the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless they are adopted by a city or county as specified in Section 101.7.
(Ord. 0-19-1357, 11-13-2019)

25.13.05: AMENDMENT OF SECTION 301.1.1:

Notwithstanding the provisions of section 25.13.01 of this article, section 301.1.1 of the Green Building Standards Code is amended to read as follows:

Section 301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings. Code sections relevant to additions and alterations shall only apply to the portions of the building being added or altered within the scope of the permitted work.
(Ord. 0-19-1357, 11-13-2019)

25.13.06: AMENDMENT OF SECTION 5.408.3:

Notwithstanding the provisions of section 25.13.01 of this article, section 5.408.3 of the Green Building Standards Code is amended to read as follows:

5.408.3 Excavated soil and land clearing debris [BSC] 100 percent of trees, stumps, rocks and associated vegetation and soils resulting primarily from land clearing shall be reused or recycled.

For a phased project, such material may be stockpiled on site until the storage site is developed.

Exception: Reuse, either on-or off-site, of vegetation or soil contaminated by disease or pest infestation.

Notes:

1. If contamination by disease or pest infestation is suspected, contact the County Agricultural Commissioner and follow its direction for recycling or disposal of the material. (www.cdfa.ca.gov/exec/county/ county_contacts.html)

2. For a map of known pest and/or disease quarantine zones, consult with the California Department of Food and Agriculture. (www.cdfa.ca.gov)

3. Contaminated soil shall not be reused and shall be disposed of or remediated in accordance with relevant regulations.
(Ord. 0-19-1357, 11-13-2019)

25.13.07: AMENDMENT OF SECTION 601.1:

Notwithstanding the provisions of section 25.12.01 of this article, section 601.1 is added to the Green Building Standards Code to read as follows:
601.1. This section lists the organization and standards that are referenced in various sections of this document. The standards are listed herein by the promulgating agency of the standard. (Ord. 0-19-1357, 11-13-2019)

25.13.08: VIOLATIONS:

Any person, firm or corporation violating any of the provisions or failing to comply with any of the mandatory requirements of this article shall be guilty of a misdemeanor and upon conviction thereof shall be punishable as provided in section 01.04.03 A of this code. Each such person shall be guilty of a separate offense for each and every day during any portion of which any violation of any provision of this article is committed, continued or permitted by any such person, and he/she shall be punishable as herein provided.
(Ord. 0-19-1357, 11-13-2019)
Section 14. New Article 14 Reference Standards Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 14

REFERENCED STANDARDS CODE
SECTION:

25.14.01: Referenced Standards Code Adopted

25.14.01: REFERENCED STANDARDS CODE ADOPTED:

Except as hereinafter provided, the California Referenced Standards Code, 20252 Edition, as published by the California Building Standards Commission, is hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the Referenced Standards Code of the City. A copy of said code shall be located in the Planning and Building Department and shall be, at all times, maintained by the Planning and Building Department for use and examination by the public. (Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023) Section 15. New Article 15 Small Residential Rooftop Solar Energy Systems is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 15

SMALL RESIDENTIAL ROOFTOP SOLAR ENERGY SYSTEMS
SECTION:

25.15.01: Expedited Permitting Of Small Residential Rooftop Solar Energy Systems

25.15.01: EXPEDITED PERMITTING OF SMALL RESIDENTIAL ROOFTOP SOLAR ENERGY SYSTEMS:

A. Small Residential Rooftop Solar Energy System Defined: "Small residential rooftop solar energy system" shall have the same meaning as provided in the solar rights act, Government Code section 65850.5(j)(3), as the same may be amended from time to time.

B. Small Residential Rooftop Solar Energy System Standard Plan And Permit Application Checklist:

1. The city shall adopt standard plans and a checklist of all requirements with which small residential rooftop solar energy systems shall comply to be eligible for expedited review. The small residential rooftop solar energy system standard plans and checklist shall substantially conform to recommendations for expedited permitting, including the checklist and standard plans, contained in the most current version of the "California Solar Permitting Guidebook" adopted by the governor's office of planning and research.

2. All documents required for the submission of a small residential rooftop solar energy system permit application, the standard plan(s), and checklist shall be made available on the publicly accessible city website.

3. Electronic submittal of the required permit application and documents by e-mail or facsimile shall be available to all small residential rooftop solar energy system permit applicants.

An applicant's electronic signature shall be accepted on all forms, applications, and other documents in lieu of a wet signature. Electronic permit applications shall be submitted through the method of electronic submittal specified by the building official.

C. Permit Application Review:

1. An application that satisfies the information requirements in the checklist(s) and standard plans shall be deemed complete.

2. If an application is deemed incomplete, a written correction notice detailing all deficiencies in the application and any additional information or documentation required to be eligible for expedited permit issuance shall be sent to the applicant for resubmission.

3. The building official shall issue a building permit the same day for over the counter applications, or within one to three (3) business days for electronic applications, upon receipt of a complete application that meets the requirements of the city's standard checklist and plan(s), or as soon thereafter as may be practicable. Review of the application shall be limited to the building official's review of whether the application meets local, state, and federal health and safety requirements.

4. Any condition imposed on a permit shall be designed to mitigate the specific, adverse impact upon health and safety at the lowest possible cost.

D. Inspection Requirements:

1. Inspection requests may be submitted by e-mail or facsimile.

2. Only one inspection shall be required for small residential rooftop solar energy systems eligible for expedited review.

3. The inspection shall be done in a timely manner. The building official shall strive to schedule an inspection within two (2) business days of a request and provide a two (2) hour inspection window.

4. If a small residential rooftop solar energy system fails inspection, a subsequent inspection is authorized but need not conform to the requirements of this section. (Ord. 0-15-1298, 9-9-2015) Section 16. New Article 16 Appendix J Los Angeles County Grading Standards is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 16

APPENDIX J LOS ANGELES COUNTY GRADING STANDARDS
SECTION:

25.16.01: Appendix J Los Angeles County Grading Standards Code Adopted

25.16.01: APPENDIX J LOS ANGELES COUNTY GRADING STANDARDS CODE ADOPTED:

Except as hereinafter provided, the Los Angeles County Appendix J Standards Code, 2019 2022 Edition, as published by the Los Angeles County Department of Public Works, is hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the Los Angeles County Appendix J Grading Standards Code of the City. A copy of said Code shall be located in the Planning and Building Department and shall be, at all times, maintained by the Planning and Building Department for use and examination by the public. (Ord. 0-19-1357, 11-13-2019)
Section 17. New Article 17 Existing Building Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 17

EXISTING BUILDING CODE
SECTION:

25.17.01 Existing Building Code Adopted

25.17.01: EXISTING BUILDING CODE ADOPTED:

Except as hereinafter provided, the California Existing Building Code, 20252 edition, as published by the California Building Standards Commission, is hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the historic building code of the City. A copy of said code shall be located in the Planning and Building Department and shall be, at all times, maintained by the Planning and Building Department for use and examination by the public.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023) Section 18. New Article 18 Historical Building Code is hereby added to Chapter 25 of the San Marino City Code to read as follows:

ARTICLE 18

HISTORICAL BUILDING CODE
SECTION:

25.18.01 Historical Building Code Adopted

25.18.01: HISTORICAL BUILDING CODE ADOPTED:

Except as hereinafter provided, the California Historical Building Code, 20252 Edition, as published by the California Building Standards Commission, is hereby adopted by reference and incorporated herein as though fully set forth herein and shall constitute the Historical Building Code of the City. A copy of said code shall be located in the Planning and Building Department and shall be, at all times, maintained by the Planning and Building Department for use and examination by the public.
(Ord. 0-19-1357, 11-13-2019; amd. Ord. O-22-1400, 1-11-2023) SECTION 18. PUBLICATION
The Mayor shall sign and the City Clerk shall attest to the adoption of this Ordinance and shall cause the same to be published as required by law.

SECTION 19. EFFECTIVE DATE
This ordinance shall take effect 30 days following publication by title and summary.

PASSED, APPROVED, AND ADOPTED at a regular meeting of the City Council of the City of San Marino held on September 26, 2025.

_____________________________________

GRETCHEN SHEPHERD ROMEY,
MAYOR

ATTEST:
_________________________

CITY CLERK

ALISON WALKER
APPROVED AS TO FORM:
_________________________

JOSEPH MONTES

CITY ATTORNEY