(ALL STYLES)
*OWNER/APPLICANT REQ. TO SELECT ONE OPTION FOR ALL OF THE FOLLOWING AND MARK THROUGH NON-APPLICABLE OPTIONS AND DETAILS THROUGHOUT SET:
WATER HEATER
(B) ALTERNATIVE WATER HEATER WITH STIPULATION THAT NEW T24 ENERGY REPORT IS PROVIDED. MFR. & MODEL:______________________________________ (A) NORTHWEST ENERGY EFFICIENCY ALLIANCE (NEEA) RATED HEAT PUMP WATER HEATER; SPECIFIC BRAND/MODEL MUST BE INSTALLED (PER TITLE 24). *OWNER OR APPLICANT TO SELECT (1) OF THE (3) FOLLOWING STYLES (BELOW) AND ONE OF EACH OF THE SUBSEQUENT OPTIONS THEREIN. FOR CLARITY, CROSS OUT OTHER STYLES AND STYLE OPTIONS THROUGHOUT THE ENTIRE DRAWING SET.
ELECTRICAL PANEL (SEE PLANS & SITE PLAN FOR LOCATION)
(B) A NEW ELEC. SUBPANEL CONNECTS TO THE ELEC. MAIN PANEL OF 220 AMP ON THE PRIMARY HOME WITH A 225 AMP MIN. BUSBAR RATING
(A) NEW ELEC. MAIN PANEL OF 200 AMP MIN. WITH 225 AMP MIN. BUSBAR RATING (C) NEW ELEC. MAIN PANEL MIN. 400 AMP DUAL METER AT PRIMARY HOUSE WITH A NEW ELEC. SUB-PANEL AT ADU THAT CONNECTS TO THE MAIN PANEL OPTIONAL SLIDING DOOR @ KITCHEN/LIVING
(B) NO; WINDOW 7 TO REMAIN
(A) YES; REPLACE W/ DOOR X7
(A) EXT. TOUNGE & GROOVE
(B) FIBER CEMENT
(C) EXT. GRADE PLYWOOD
EXTERIOR EAVES, RAKES, & SOFFITS MATERIAL SELECTION
HORIZONTAL SIDING
(A) FIBER CEMENT LAP SIDING (CRC R703.10.2)
(B) FIBER CEMENT PANEL SIDING (CRC R703.5)
STYLE-BASED OPTIONS
OPTION SELECTION
CRAFTSMAN
(C) EXT. GRADE WOOD; LAP SIDING (CRC R703.5)
SHINGLE SIDING
(A) FIBER CEMENT (CRC R703.6)
(B) EXT. GRADE WOOD (CRC R703.6)
EXTERIOR TRIM ELEMENTS
(A) FIBER CEMENT
(B) EXT. GRADE WOOD
BASE TRIM
(A) YES
(B) NO
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:45:14 PM
TITLE SHEET - PLAN 3 -
CRAFTSMAN
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
G-008
04/14/2026
RECORD SET
GENERAL
G-008 TITLE SHEET - PLAN 3 - CRAFTSMAN
G-101 GENERAL NOTES
G-102 GENERAL NOTES, ABBREVIATIONS, & SYMBOLS
G-201 CAL GREEN RESIDENTIAL MANDATORY MEASURES
G-202 CAL GREEN RESIDENTIAL MANDATORY MEASURES
ENERGY COMPLIANCE
T24-000 ENERGY MANDATORY REQUIREMENTS
T24-005 ENERGY COMPLIANCE REPORT - PLAN 3
T24-006 ENERGY COMPLIANCE REPORT - PLAN 3
ARCHITECTURAL SITE
AS-101 EXAMPLE SITE PLAN
AS-102 ARCHITECTURAL SITE PLAN
ARCHITECTURAL
A3-101 FLOOR PLANS
A3-112 ELECTRICAL & MECHANICAL PLANS
A3-122 ROOF PLANS & REFLECTED CEILING PLANS-CRAFTSMAN
A3-202 EXTERIOR ELEVATIONS & BUILDING SECTIONS-CRAFTSMAN A3-111 FINISH PLANS
ARCHITECTURAL DETAILS
AD-901 ARCHITECTURAL DETAILS - COMMON - FLASHING
AD-902 ARCHITECTURAL DETAILS - COMMON
AD-903 ARCHITECTURAL DETAILS - COMMON - ROOF
AD-904 ARCHITECTURAL DETAILS - AGING-IN-PLACE
AD-907 ARCHITECTURAL DETAILS - CRAFTSMAN
AD-908 ARCHITECTURAL DETAILS - CRAFTSMAN
AD-913W ARCHITECTURAL DETAILS - ASPHALT SHINGLE ROOF - WUI
STRUCTURAL
S-101 SHEET INDEX, ABBREVIATIONS, & SYMBOLS
S-102 GENERAL NOTES
S-103 GENERAL NOTES, SPECIAL INSPECTION & TESTS
S-201 PIER FOUNDATION & ROOF FRAMING PLANS - STICK
S-202 PIER FOUNDATION & ROOF FRAMING PLANS - TRUSS
S-301 TYPICAL CONCRETE DETAILS
S-302 TYPICAL CONCRETE DETAILS
S-311 CONCRETE DETAILS
S-401 TYPICAL WOOD DETAILS
S-402 TYPICAL WOOD DETAILS
S-403 TYPICAL WOOD DETAILS
S-404 TYPICAL WOOD DETAILS
S-421 ROOF FRAMING DETAILS
S-422 ROOF FRAMING DETAILS
S-431 ROOF FRAMING DETAILS
Grand total: 37
SAN RAMON PROTOTYPE ACCESSORY DWELLING UNIT - PLAN 3 - CRAFTSMAN SQUARE FOOTAGE CONDITIONED?
ADU-PLAN 3 720 SF CONDITIONED
COVERED PORCH-PLAN 3 183 SF UNCONDITIONED
STORAGE-PLAN 3 8 SF UNCONDITIONED
PROJECT DIRECTORY PROJECT INFORMATION
UTILITIES
SHEET INDEX
ADDRESS:
CONTACT:
EMAIL:
PHONE:
RRM DESIGN GROUP
3765 S HIGUERA ST, SUITE 102
SAN LUIS OBISPO, CA 93401
P:(805) 543-1794
ARCHITECT
RANDY RUSSOM
[email protected]
USER LICENSE AGREEMENT
SIGNATURE DATE
VICINITY MAP (TO BE PROVIDED BY OWNER OR APPLICANT)
WATER AND SEWER SERVICE _________________________________________
ELECTRICAL SERVICE
GAS SERVICE
SEWER SERVICE
GARBAGE SERVICE
CABLE SERVICE
_________________________________________
_________________________________________
_________________________________________
_________________________________________
_________________________________________
(TO BE PROVIDED BY APPLICANT OR OWNER)
*FOR BUILDING DEPARTMENT REVIEW, INITIAL WHEN SECTION HAS BEEN REVIEWED
1. ANY PROPOSED ENERGY STORAGE SYSTEM (ESS) SHALL FOLLOW SINGLE-FAMILY RESIDENTIAL MANDATORY REQ. SUMMARY SECTION 150.0(s) AND WILL REQUIRE A SEPARATE PERMIT TO BE PULLED BY APPLICANT.
2. VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION (VERIFICATION DETAILS FROM VCHP STAFF REPORT, APPENDIX B, AND RA3) (PER TITLE 24).
3. THIS PLAN IS INTENDED FOR FLAT LOTS (SLOPING LESS THAN 10" ACROSS THE
LONGEST BUILDING DIMENSION), WITHOUT HIGHLY EXPANSIVE OR LIQUEFIABLE
SOILS, WHERE THE MAIN DWELLING UNIT IS SUPPORTED IN SHALLOW FOOTINGS WITH SLABS ON GRADE CONSTRUCTION. IF THE PROJECT SITE DEVIATES FROM ANY
OF THE AFOREMENTIONED QUALITIES, AS DETERMINED BY THE BUILDING OFFICIAL,
THERE PRE-APPROVED ADU FOUNDATION PLANS AND DETAILS ARE NOT APPLICABLE.
ADDITIONAL INFORMATION:
IS THE ADU 5' - 0" OR LESS TO ANY PROPERTY LINE AND/OR IS THE ADU 10' - 0" OR LESS FROM ANY ADJACENT BUILDING OR STRUCTURE?
NO
SUPPORTING DOCUMENTS
PREPARED BY:
DATE PREPARED:
JOB NUMBER:
CARSTAIRS ENERGY
ENERGY COMPLIANCE
FEBRUARY 13, 2026
26-01086
PLEASE PROVIDE THE WASTE RECYCLE FORM FILLED OUT AND SIGNED PRIOR TO ISSUANCE. THE OWNER/APPLICANT/CONTRACTOR/PERSON DOING THE WORK IS REQUIRED TO RECYCLE 75% OF ALL PROJECT CONSTRUCTION AND DEMOLITION DEBRIS.
UTILITY, GRADING, AND DRAINAGE PLAN TO BE PROVIDED BY OTHERS.
HERS VCHP: HERS RATER WILL NEED TO FOLLOW THE VERIFICATION AND TESTING
PROTOCOL FOR THE VARIABLE CAPACITY HEAT PUMP CREDIT REQUIREMENTS,
INCLUDING BUT NOT LIMITED TO, VERIFIED REFRIGERANT CHARGE, VERIFIED MINIMUM HSPF AND EER/SEER, AND CAPACITY; DUCTLESS INDOOR UNITS AND THE COMPONENTS ARE WITHIN THE CONDITIONED ENVELOPE; AND AIRFLOW PROVIDED TO ALL HABITABLE SPACES (BEDROOMS AND LIVING SPACE).
THE FOLLOWING IS A SUMMARY OF THE FEATURES THAT MUST BE FIELD-VERIFIED BY
A CERTIFIED HERS RATER AS A CONDITION FOR MEETING THE MODELED ENERGY PERFORMANCE OF THIS COMPUTER ANALYSIS. REGISTERED CF2RS AND CF3RS ARE REQUIRED TO BE COMPLETED IN THE HERS REGISTRY.
• QUALITY INSULATION INSTALLATION (QII)
• INDOOR AIR QUALITY VENTILATION
• KITCHEN RANGE HOOD
• VERIFIED REFRIGERANT CHARGE
• AIRFLOW IN HABITABLE ROOMS (SC3.1.4.1.7)
• VERIFIED HEAT PUMP RATED HEATING CAPACITY
• WALL-MOUNTED THERMOSTAT IN ZONES GREATER THAN 150 FT2 (SC3.4.5) • DUCTLESS INDOOR UNITS LOCATED ENTIRELY IN CONDITIONED SPACE (SC3.1.4.1.8)
HERS QII REQUIRED
OWNER/APPLICANT HAS COMPLETED SPECIAL INSPECTION FORM
OWNER/APPLICANT SIGNATURE: _____________________________ SEE SHEET S-103 FOR REQUIRED SPECIAL INSPECTIONS
A REGISTERED DESIGN PROFESSIONAL SHALL COMPLETE THE CITY OF SAN RAMON STATEMENT OF REQUIRED SPECIAL INSPECTIONS CERTIFICATE (FORM PLG-240) PRIOR TO PERMIT ISSUANCE. IDENTIFY THE TYPE OF WORK REQUIRING SPECIAL
INSPECTIONS IN THE PLANS AND THE INDIVIDUALS OR FIRMS RESPONSIBLE FOR THE SPECIAL INSPECTION ELEMENT(S). FOR FURTHER INSTRUCTIONS SEE S-103.
SPECIAL INSPECTIONS REQ'D
OWNER/APPLICANT SIGNATURE:____________________________
OWNER/APPLICANT TO SIGN USER AGREEMENT BELOW:
BY USING THESE PERMIT READY ACCESSORY DWELLING UNIT CONSTRUCTION
DOCUMENTS, THE USER AGREES TO RELEASE, HOLD HARMLESS, AND INDEMNIFY
THE CITY OF SAN RAMON, ITS ELECTED OFFICIALS AND EMPLOYEES, RRM DESIGN
GROUP, AND THE ARCHITECT OR ENGINEER WHO PREPARED THESE
CONSTRUCTION DOCUMENTS FROM ANY AND ALL CLAIMS, LIABILITIES, SUITS AND
DEMANDS ON ACCOUNT OF ANY INJURY, DAMAGE OR LOSS TO PERSONS OR
PROPERTY, INCLUDING INJURY OR DEATH, OR ECONOMIC LOSSES, ARISING OUT OF THE USE OF THESE CONSTRUCTION DOCUMENTS.
THE PLANS ATTACHED HERE ARE APPROVED FOR ONLY USE IN CITY OF SAN RAMON. NO DEVIATIONS, ALTERATIONS, OR OPTIONS BEYOND THOSE
SPECIFICALLY INDICATED IN THE PLANS ARE ALLOWED WITHOUT PRIOR APPROVAL BY THE ISSUING JURISDICTION AND CHIEF BUILDING OFFICIAL. ANY
UNAPPROVED PLAN MODIFICATIONS MAY BE DEVELOPED THROUGH RRM DESIGN GROUP AND THE APPROVING JURISDICTION IF REQUIRED. THIS SET OF PLANS SHALL NOT BE USED FOR A PUBLIC HOUSING PROJECT.
YES; IF YES, FIRE RATED WALL, ROOF & PROJECTIONS REQUIRED PER 2025 CBC, CHAPTER 2. FIRE RATED WALL DETAIL: 54/A-902. FIRE RATED ROOF DETAIL: 22/A-903
IF YES, FIREBLOCKING IS REQUIRED IN PROJECTIONS, RAKES AND EAVES.
SEE DETAILS: 41/A-905, 42/A-905, 41/A-907, 42/A-907, 41/A-909, & 42/A-909 (TO BE PROVIDED BY
OWNER / APPLICANT)
APPLICANT:
ADDRESS:
CONTACT:
EMAIL:
PHONE:
OWNER:
ADDRESS:
CONTACT:
EMAIL:
PHONE:
SITE INFORMATION:
APN:
ZONING:
REAR: 4' - 0" (A.B. NO. 86)
FRONT:
SIDES: 4' - 0" (A.B. NO. 86)
SETBACKS
_____________
_____________
_____________
REQUIRED: PROPOSED:
SETBACK RESTRICTIONS - FIRE RATINGS:
WASTE WATER:
SEWER
*FOR BUILDING DEPARTMENT REVIEW, INITIAL WHEN SECTION HAS BEEN REVIEWED
STAFF INITIALS
BUILDING INFORMATION:
CONSTRUCTION TYPE: VB
MAX HEIGHT ALLOWED: 16' - 0"
ZONING:
SPRINKLERED: (SEE FIRE SPRINKLER
SECTION ON THIS SHEET)
MAX HEIGHT PROPOSED:
NUMBER OF STORIES: 1 OCCUPANCY GROUP: R-3
PROJECT ADDRESS: _________________________________________________________________________________
SEPARATE PERMITS DEFERRED SUBMITTAL
SOLAR PV SYSTEM TRUSS CALCULATIONS
PROJECT SCOPE:
1. 2.
CONSTRUCTION OF A NEW DETACHED 1 STORY 708 SF ACCESSORY DWELLING UNIT WITH 1 BEDROOMS AND 1 BATH.
ALL THE WORK SHOWN IN THE DRAWINGS AND SPECIFICATIONS.
YES, PV SYSTEM REQUIRED
NO, PV NOT REQUIRED (FOR ADUS 652 SF OR SMALLER) PER CALIFORNIA ENERGY CODE SECTION 150.1(C)14 EXCEPTION (IF NO, OWNER/APPLICANT REQ.
TO SELECT ONE):
1) FOR STEEP SLOPE ROOFS, WITH NORTHERLY AZIMUTH THAT LIES BETWEEN 300 DEGREES AND 90 DEGREES FROM TRUE NORTH. IF THE SARA IS LESS THAN 80 CONTIGUOUS SQUARE FEET.
2) PV SYSTEM SIZE SPECIFIED BY SECTION 150.1(C)14 IS LESS THAN 1.8 KWDC. 3) BUILDINGS W/ APPROVED ROOF DESIGNS, WHERE THE ENFORCEMENT
AUTHORITY DETERMINES IT IS NOT POSSIBLE FOR THE PV SYSTEM 4) FOR BUILDINGS THAT ARE APPROVED BY THE LOCAL PLANNING DEPARTMENT PRIOR TO JANUARY 1, 2020 WITH MANDATORY CONDITIONS FOR APPROVAL. 5) PV SYSTEM SIZES DETERMINED USING EQUATION 150.1-C MAY BE REDUCED BY 25 PERCENT IF INSTALLED IN CONJUNCTION WITH A QUALIFYING BATTERY STORAGE SYSTEM.
OTHER, (REQ. APPROVAL) SPECIFY:_________________________________________ SOLAR READY REQUIREMENTS SHALL BE IMPLEMENTED. FOR MORE INFORMATION SEE "SOLAR READY NOTES" ON SHEET G-102.
PHOTOVOLTAIC SYSTEM (PV)
*SEPARATE SUBIMTTAL
+/- 13'-3"
SIGNATURE DATE
1. DETAILED SPRINKLER PLANS SHALL BE SUBMITTED TO THE FIRE PREVENTION BUREAU AND APPROVED PRIOR TO INSTALLATION. PLANS AND INSTALLATION MUST BE BY A C16 LICENSED SPRINKLER CONTRACTOR.
2. SECTION 903.3.1.3 NFPA 13D SPRINKLER SYSTEMS AUTOMATIC FIRE SPRINKLER SYSTEMS INSTALLED IN ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3.
3. SECTION 903.2.8 GROUP R AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3 SHALL BE PROVIDED THROUGHOUT ALL BUILDINGS WITH A GROUP R FIRE AREA.
4. SECTION 903.2.8.1 GROUP R-3 AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.3 SHALL BE PERMITTED IN GROUP R-3 OCCUPANCIES.
5. LOCATION AND SIZE OF WATER SERVICE UNDERGROUND SHALL BE INSTALLED AS SHOWN ON APPROVED FIRE SPRINKLER PLANS. A MINIMUM 1 INCH WATER SHALL BE INSTALLED.
6. A FIRE UNDERGROUND FLUSH CERTIFICATION SHALL BE REQUIRED AT FINAL INSPECTION.
7. A HYDRO INSPECTION OF THE FIRE SPRINKLER SYSTEM IS REQUIRED PRIOR TO FRAME INSPECTION. ONLY THE NEW PIPING SHALL BE TESTED.
FIRE PROTECTION
FIRE SPRINKLERS (WHEN REQUIRED) NOTES:
DOES THE PRIMARY RESIDENCE HAVE NFPA 13D SPRINKLERS?
NO: THEREFORE, THE PROPOSED ADU IS NOT REQUIRED TO BE SPRINKLERED YES: THEREFORE, THE PROPOSED ADU IS REQUIRED TO BE SPRINKLERED (TO BE PROVIDED BY
OWNER / APPLICANT)
1. PORTIONS OF THE CITY OR COUNTY ARE LOCATED WITHIN THE WILDLANDURBAN INTERFACE. TO DETERMINE IF YOUR STRUCTURE IS LOCATED IN A WUI FIRE AREA PLEASE VISIT THE U.S. FIRE ADMINISTRATION WEBSITE:
HTTPS://SRVFIRE.MAPS.ARCGIS.COM/APPS/WEBAPPVIEWER/INDEX.HTML? ID=D55B2C2388A14733AD7FE72E86C0693E
IS YOUR STRUCTURE IN A WUI FIRE AREA?
YES NO
2. IF YOUR STRUCTURE IS LOCATED IN THE WUI FIRE AREA (EMBER ZONE OR
IGNITION ZONE), ALL CONSTRUCTION OF THE ADU STRUCTURE MUST COMPLY WITH THE CWUIC 504.
3. THIS PROTOTYPE PLAN PROVIDES DESIGNS THAT COMPLY WITH THE PROVISIONS REQUIRED BY THE CWUIC 504. PLEASE SEE APPLICABLE DETAIL SHEET(S): A-911
WILDLAND-URBAN INTERFACE FIRE AREA (WUI):
FIRE SPRINKLERS:
ADDRESS:
CONTACT:
EMAIL:
PHONE:
RRM DESIGN GROUP
3765 S HIGUERA ST, SUITE 102
SAN LUIS OBISPO, CA 93401
P:(805) 543-1794
STRUCTURAL
JESSICA MEADOWS
[email protected]
PUBLIC SET
FOR USE IN THE CITY OF SAN RAMON
SITE PLAN LEGEND
EASTMENT
SETBACK
PROPERTY LINE
(E) STREET NAME
OVERALL DIMENSION OF EXISTING RESIDENCE
XX' - XX"
4' - 0" MIN. SETBACK
XX' - XX" XX' - XX" XX' - XX"
OVERALL DIMENSION OF EXISTING RESIDENCE
XX' - XX" XX' - XX"
OVERALL DIMENSION OF NEW ADU
XX' - XX"
XX' - XX" FROM ADU TO (E) RESIDENCE
OVERALL DIMENSION OF EXISTING RESIDENCE
XX' - XX" XX' - XX"
XX'-XX" (DISTANCE)
(E) SINGLE FAMILY
RESIDENCE EXAMPLE
(ADDRESS)
(FOOTPRINT SF)
(N) ACCESSORY
DWELLING UNIT
EXAMPLE
SXX° XX'X"E
XX'-XX" (DISTANCE)
NXX° XX'X"W
NXX° XX'X"W (PROPERTY LINE BEARINGS)
XX'-XX" (DISTANCE)
SXX° XX'X"E
SETBACK
MIN 4'
MIN 4' - 0" SETBACK
XX' - XX"
MIN. 5' - 0" MIN. 5' - 0"
(E) PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
XX'-XX" (DISTANCE)
(E) SIDEWALK
EXAMPLE
(E) PROPERTY LINE
MIN. 4' - 0" SETBACK
XX' - XX"
(E) RETAINING WALL EXAMPLE
(DISTANCE FROM PROPERTY LINE TO (E) RESIDENCE
XX' - XX"
X XX X X X X X
(N) MECHANICAL EQUIPMENT LOCATION
EXAMPLE; NOT LESS THAN 30" OF
CLEARANCE IN WIDTH, DEPTH, & HEIGHT
SHALL BE PROVIDED TO ACCESS THE
EQUIPMENT. (2025 CMC SECTION 304.1)
(N) APPLICANT TO ILLUSTRATE AND
ANNOTATE PROPOSED APRONS,
LANDINGS, PORCHES, OVERHANGS, MECH.
/ ELEC. ITEMS AND PROPOSED ACCESS
POINTS
LOCATE ELECTRICAL (ALL) PANELS
SEE TITLE SHEET FOR PANEL OPTIONS AND
MAXIMUM AMPERAGE FOR THE PROPOSED ADU.
(E) EXISTING SWIMMING POOL
EXAMPLE (OWNER / APPLICANT
TO PROVIDE SF)
EASEMENT
EXAMPLE
(ANY/ALL
SHALL
BE
SHOWN)
SETBACK
XX' - XX"
XX' - XX"
MIN. 10'
(N) ASSUMED PROPERTY LINE
(E) SETBACK
(E) SETBACK
(E) SETBACK
XX'-XX" SETBACK
DISTANCE OF NEAREST POINT OF ADU TO CENTERLINE OF
IMAGINARY LINE BETWEEN THE TWO BUILDINGS (UNDER 5' - 0" 1- HOUR FIRE-RATED WALL AND 1-HOUR FIRE-RATED EAVE REQUIRED).
DISTANCE OF NEAREST POINT OF ADU TO
ADJACENT PROPERTY LINE (WHEN UNDER
5' - 0," 1-HOUR FIRE-RATED WALL AND 1-
HOUR FIRE-RATED RAKE/EAVE REQUIRED).
(FOOTPRINT SF)
PROVIDE ALL DIMENSIONS FOR
ALL (E) AND/OR (N) PAVED AREAS
PROVIDE ALL DIMENSIONS, OF (E) DRIVEWAY(S)
XX' - XX"
XX' - XX"
XX' - XX"
XX' - XX"
(E) FENCE EXAMPLE
(PROVIDE DIMENSIONS)
(E) FENCE EXAMPLE
(PROVIDE DIMENSIONS)
XX
(E) SIDEWALK
EXAMPLE
(CENTERLINE OF STREET)
OWNER/APPLICANT TO
INDICATE MAIN ENTRANCE
SITE PLAN CHECKLIST
DRAWING SCALE - SITE PLAN SHOULD BE DRAWN TO A MEASURABLE SCALE.
PROPERTY LINES
SHOW OUTLINE OF PROPERTY USING DASHED LINE IN LEGEND. INDICATE THE BEARING AND DISTANCE OF THE PROPERTY LINE.
LABEL YARDS
LABEL FRONT, REAR, SIDE YARDS, AS WELL AS DRIVEWAYS, PATHWAYS AND ANY OTHER HARDSCAPE.
SETBACKS
DIMENSION THE DISTANCE BETWEEN BUILDINGS AND PROPERTY LINES, AS WELL AS BUILDINGS TO OTHER STRUCTURES. SETBACKS TO SIDE AND REAR PROPERTY SIDE SHALL BE A MINIMUM OF (4' - 0").
EASEMENTS
REFER TO LEGEND. MUST INCLUDE ALL APPLICABLE EASEMENTS.
PROPOSED STRUCTURE SHALL COMPLY WITH EASEMENT REQUIREMENTS.
PROVIDE THE EXACT LOCATION AND LABEL ALL OF THE EXISTING & PROPOSED
UTILITIES ON THE SITE PLAN
A. THIS INCLUDES BUT IS NOT LIMITED TO UTILITIES, POLES, SEPTIC, SEWER, DRAINS, ELECTRICAL, GAS METERS, LINES, AND ANY PHOTOVOLTAIC.
B. INDICATE SEWER ELEVATION OF LATERAL AND MAIN CONNECTION.
IF ON SEPTIC SYSTEM, PROVIDE DEPARTMENT OF ENVIRONMENTAL
HEALTH (DEH) EXHIBIT WITH LEACH LINES SHOWN AND AREA FOR NEW LEACH LINES. SEWER MAIN EXTENSION MAY BE REQUIRED. INCLUDE
LOCATIONS AND ALL ELEVATIONS OF PROPOSED SEPTIC / SEWER / LEACH LINES. PROVIDE INVERT ELEVATIONS AT CLEANOUT, SEWER MAIN
CONNECTION, ADU CONNECTION, AND AT ANY OTHER CONNECTION POINTS.
C. PLEASE SPECIFY ON THE PLANS IF THE ADU WILL HAVE NEW
INDEPENDENT SERVICES DIRECTLY FROM THE PUBLIC RIGHT OF WAY
CONNECTION OR IF THE SERVICES WILL BE BRANCHED OFF THE EXISTING MAIN LINES ON THE PROPERTY.
D. JUSTIFY PIPE SIZES SHOWN ON THE PLAN ARE ADEQUATE FOR THE PROPOSED ADU SERVICES. IF THE SERVICES ARE CONNECTED TO THE
EXISTING MAIN SERVICES, THEN PROVIDE JUSTIFICATION THAT THE
EXISTING MAINS CAN HANDLE THE NEW INCREASED FLOWS OF THE ADU FOR WATER SUPPLY AND SANITARY SEWER SYSTEMS. PLEASE USE CPC TABLE 610.3, TABLE 610.4, AND SECTION 610.5 FOR JUSTIFICATION. NOTE,
IF USING APPENDIX A SIZING CRITERIA, PLEASE INCLUDE THE CPC APPENDIX A CHART ON THE PLAN.
LABEL STREETS & SIDEWALKS
FOOTPRINT OF PROPOSED ADU - REFER TO LEGEND FOR FOOTPRINT AT 10'=1" SCALE
DIMENSION BUILDING SEPARATION
DIMENSION THE DISTANCE BETWEEN THE PROPOSED ADU AND ANY
EXISTING STRUCTURES
AREA OF EXISTING BUILDING - INDICATE THE SQUARE FOOTAGE OF THE EXISTING HOUSE.
LOCATION OF RAIN WATER LEADERS - THE ROOF DRAINS SHOULD DRAIN AWAY FROM THE PROPERTY LINES AND INTO THE LANDSCAPE AREA.
SCALE:
1 EXAMPLE SITE PLAN /10" = 1' - 0"
SWIMMING POOLS - ALL EXISTING SWIMMING POOLS SHALL BE SHOWN ON THE SITE PLAN AND SHALL HAVE 10' MINIMUM SETBACK TO THE NEW ADU STRUCTURE.
FOOTPRINT OF ALL EXISTING AND PROPOSED BUILDINGS - PLOT THE
PROPOSED ADU BUILDING FOOTPRINT ALONG WITH ANY OTHER EXISTING BUILDINGS ONSITE. THIS INCLUDES ALL STRUCTURES / PORCHES / GAZEBOS.
PLOT ANY OPTIONAL COVERED PATIOS (WHEN SELECTED).
NORTH ARROW
PORCHES - THERE SHALL BE NO MORE THAN 30 INCHES MEASURED
VERTICALLY TO THE FLOOR OR GRADE BELOW (INCLUDING FLOORS, STAIRS, RAMPS, AND LANDINGS) ANYWHERE MEASURED LESS THAN 36 INCHES HORIZONTALLY TO THE EDGE OF THE PORCH/SLAB/SURFACE OF THE RAIL.
INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD.
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS
2. REFER TO STRUCTURAL PLANS FOR FURTHER INFORMATION
3. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY PER 2025 CRC, SECTION 308.1.
4. NOT LESS THAN 30" OF CLEARANCE IN WIDTH, DEPTH, & HEIGHT SHALL BE PROVIDED TO ACCESS EXTERIOR MECHANICAL EQUIPMENT. SHOW
LOCATION ON SITE PLAN & LABEL (2025 CMC SECTION 304.1 & 2025 CPC 504.3).
5. PROPOSED ADU IS TO BE FULLY ELECTRIC. INSTALLATION OF A GAS LINE TO THE PROPOSED ADU WILL NOT BE PERMITTED.
6. CALL BEFORE YOU DIG! CONTACT UNDERGROUND SERVICE ALERT (USA) AT 1-800-227-2600 AT LEAST 2 WORKING DAYS BEFORE EXCAVATING.
7. UNLESS OTHERWISE NOTED ON THE PLANS, FINISHED GROUND SURFACES SHALL BE GRADED TO DRAIN THE FINISHED SITE PROPERLY WITHIN 10-FEET OF ANY BUILDING FOUNDATION WITH A SLOPE OF 5% AWAY FROM ANY BUILDING OR STRUCTURE. ALL EXTERIOR HARDSCAPE WITHIN 10-FEET OF A BUILDING FOUNDATION SHALL BE INSTALLED WITH A 2% MINIMUM SLOPE AWAY FROM ANY BUILDING OR STRUCTURE. DRAINAGE SWALES SHALL BE A
1.5% MINIMUM SLOPE. ALL GRADED SLOPES SHALL HAVE A MAXIMUM SLOPE OF 3H TO 1V (33%), UNLESS SHOWN OTHERWISE ON THE PLANS.
8. LOT GRADING SHALL CONFORM AT THE PROPERTY LINES AND SHALL NOT
SLOPE TOWARD PROPERTY LINES IN A MANNER WHICH WOULD CAUSE STORM WATER TO FLOW ONTO NEIGHBORING PROPERTY. HISTORIC
DRAINAGE PATTERNS SHALL NOT BE ALTERED IN A MANNER TO CAUSE DRAINAGE PROBLEMS TO NEIGHBORING PROPERTY.
9. NEW RAINWATER DOWNSPOUTS SHALL BE DISCONNECTED AND DIRECT RUNOFF TO A LANDSCAPED AREA. DOWNSPOUTS MAY BE CONNECTED TO A
POP-UP DRAINAGE EMITTER IN THE LANDSCAPED AREA OR MAY DRAIN TO
SPLASH BLOCKS OR COBBLESTONES THAT DIRECT WATER AWAY FROM THE BUILDING.
10. CONTRACTOR TO FIELD VERIFY EXISTING DRAINAGE. IF THE EXISTING
DRAINAGE SYSTEM IS DAMAGED DURING EXCAVATION, CONTRACTOR SHALL
REPAIR AND/OR REROUTE DRAINAGE SYSTEM AND CONNECT TO EXISTING DRAINAGE FACILITY AS NECESSARY.
11. EXISTING PUBLIC IMPROVEMENTS THAT ARE DAMAGED BY THE PROJECT CONSTRUCTION SHALL BE REPAIRED OR REPLACED. EXISTING DAMAGED
PUBLIC IMPROVEMENTS WITHIN THE PROJECT LIMITS SHALL BE REPAIRED
OR REPLACED EVEN IF THE DAMAGE OCCURRED PRIOR TO THE START OF CONSTRUCTION.
12. EROSION AND SEDIMENT CONTROL FACILITIES SHALL BE INSTALLED PRIOR TO OCTOBER 1 AND SHALL BE MAINTAINED DAILY UNTIL APRIL 30. THESE
FACILITIES SHALL CONTROL AND CONTAIN EROSION-CAUSED SILT DEPOSITS
AND PROVIDE FOR THE SAFE DISCHARGE OF SILT-FREE STORM WATERS INTO EXISTING STORM DRAIN FACILITIES. EROSION AND SEDIMENT CONTROL
SUPPLIES MUST BE KEPT ON-SITE DURING THE DRY SEASON AND EMPLOYED, AS NECESSARY PRIOR TO AND DURING RAIN EVENTS.
13. SEASONALLY APPROPRIATE BEST MANAGEMENT PRACTICES FOR THE FOLLOWING SITE MANAGEMENT CATEGORIES MUST BE IMPLEMENTED YEARROUND: 1) EROSION CONTROL; 2) RUN-ON AND RUN-OFF CONTROL; 3) SEDIMENT CONTROL; 4) GOOD SITE MANAGEMENT; AND 5) NONSTORMWATER MANAGEMENT.
14. AN ENCROACHMENT PERMIT WILL BE REQUIRED FOR ANY CONSTRUCTION
ACTIVITY WITHIN A PUBLIC STREET RIGHT OF WAY THAT HAS BEEN ACCEPTED BY THE CITY.
SITE PLAN GENERAL NOTES
LOCATION OF ELECTRICAL PANEL
SEE COVER SHEET FOR PANEL OPTION AND MAXIMUM AMPERAGE FOR THE PROPOSED ADU. SEE TITLE SHEET UNDER OPTION SELECTIONS FOR REQ. ADDITIONAL CALCULATIONS BASED ON CHOSEN ELECTRICAL PANEL.
LOCATION OF FIRE HYDRANTS
INDICATE THE LOCATION OF ALL FIRE HYDRANTS WITHIN 500 FEET OF THE PROPERTY.
DRIVEWAY / PAVED ACCESS
SHOW THE PROPOSED (OR EXISTING) DRIVEWAY / PAVED ACCESS TO THE PROPOSED ADU.
TOPOGRAPHY - SHOW 1 FT CONTOURS ON SITE AND 20 FT OFFSITE. (REQUIREMENT MAY BE WAIVED AT BUILDING OFFICIALS DISCRETION.)
SHOW ALL EV CHARGING AND ALL ASSOCIATED CIRCUITS FOR NEW AND EXISTING LOCATIONS.
NOTE: THIS IS AN EXAMPLE SITE PLAN FOR AN INTERIOR
LOT. EXACT LAYOUT, DIMENSIONS, AND BEARINGS SHALL
BE PROVIDED BY OWNER/APPLICANT.
(E) EXISTING (N) NEW
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:45:21 PM
EXAMPLE SITE PLAN
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
AS-101
04/14/2026
RECORD SET
1-HR FIRE CONSTRUCTION
IS (N) ADU LESS THAN 5' - 0" TO ANY PROPERTY LINE AND/OR IS (N) ADU 10' - 0" OR LESS FROM ANY ADJACENT BUILDING OR STRUCTURE:
YES, IF YES, FIRE-RATED WALL REQUIRED PER 2025 CRC R302.1 AT LOCATIONS WHERE THE ADU IS LESS THAN 5' FROM THE PROPERTY LINE OR 10' FROM ANY ADJACENT BUILDING OR STRUCTURE.
FIRE RATED WALL DETAIL: 54/A-902
FIREBLOCKING IS REQUIRED IN PROJECTIONS, RAKES AND EAVES. SEE DETAILS: 41/A-905, 42/A-905, 41/A-907, 42/A-907, 41/A-909, 42/A-909, 44/A-906, 32/A-908, &44/A-910
THE FIRE-RESISTANCE RATING SHALL BE PERMITTED TO BE REDUCED TO 0 HOURS ON THE UNDERSIDE OF THE EAVE OVERHANG, IF
FIREBLOCKING IS PROVIDED FROM THE WALL TOP PLATE TO THE
UNDERSIDE OF THE ROOF SHEATHING IF ONE OF THE FOLLOWING SEPARATION DISTANCES ARE MET IN APPROPRIATE TABLE: TABLE 302.1(1) & TABLE 302.1(2).
A) NON-SPRINKLERED & FIRE SEPARATION DISTANCE PROJECTIONS ARE ≥ 2'-0" - < 5'-0"
B) SPRINKLERED & FIRE SEPARATION DISTANCE
PROJECTIONS ARE ≥ 2'
NO
DOES ANY ELEVATION ON SELECTED (N) ADU HAVE ≥ 25%
OPENINGS?
YES, THEN ARE ANY OF THOSE ELEVATIONS LESS THAN 5' FROM ANY PROPERTY LINE OR 10' OR LESS FROM ANY ADJACENT BUILDING OR STRUCTURE?
IF YES, THEN FIRE-RATED CONSTRUCTION IS REQUIRED PER 2025 CRC R302.1.
NO, NO ACTION NEEDED
PUBLIC SET
FOR USE IN THE CITY OF SAN RAMON
DW
A A
3 3
C C
1 1
28' - 0"
40' - 0"
28' - 0"
KITCHEN
6 A3-202
6 A3-202
5 A3-202
5 A3-202
2 2
B B
BATH
LIVING
W.I.C.
WH
BEDROOM
6 5
8 1 2
4 4
3 6
3 5
1 2
A3-202
3 A3-202
4 A3-202
1 A3-202
HALL
10' - 7" 5' - 5" 3' - 8" 5' - 5" 2' - 11"
3' - 5 1/2" 8' - 6 1/2" 28' - 0"
EQ EQ
4' - 3" 6' - 9" 9' - 0" 3' - 9" 4' - 3"
12' - 0" 28' - 0"
COVERED PORCH
STORAGE
B01 A04 A01
A05
B05 B04
B06
14' - 0" 14' - 0"
7-3/4" MAX.
C13 A03
TYP.
M02
C08
C10
X07 G02
C01
C12
EQ EQ
7 2' - 0"
40' - 0"
1' - 10"
B38
2' - 4"
7' - 10 1/2"
3' - 7" 3' - 0"
SEE AGING-IN-PLACE 5' - 0"
DETAILS: 51/ AD-904
A06
EQ 2' - 4" EQ
EXTERIOR - 5 1/2" WOOD STUD W/ PLYWOOD SHEATHING AND
STUCCO, ONE LAYER GYPSUM WALL BOARD INTERIOR.
INTERIOR - 5 1/2" WOOD STUD W/ONE LAYER GYPSUM WALL BOARD EACH SIDE.
INTERIOR - 3 1/2" WOOD STUD W/ONE LAYER GYPSUM WALL BOARD EACH SIDE.
REFER TO DETAIL ( ) FOR ADDITIONAL INFORMATION 54/ AD-902 A2.
SOLID CORE WOOD
EXTERIOR
B.
DOUBLE SLIDING
INTERIOR
C.
SLIDING GLASS
EXTERIOR.
D.
HOLLOW CORE
WOOD INTERIOR
T T
A1.
SOLID CORE WOOD
EXTERIOR ENTRY
T
T T
RANCH CRAFTSMAN MEDITERRANEAN
A.
SINGLE HUNG.
B.
SLIDER.
EQ EQ
PER SCHED.
PER SCHED. PER SCHED.
PER SCHED.
A
2 B
COVERED PORCH
X07
G02
20' - 0"
10" 6' - 8" 12' - 6"
10"
2' - 4" 11' - 8"
14' - 0"
7 1
1 A
2 B
COVERED PORCH
X07
G02
8' - 3" 11' - 9"
2' - 0" 5' - 0" 9' - 0"
20' - 0"
16' - 0"
7 1
1 A
2 B
1' - 0" 9' - 0" 5' - 0"
8' - 3" 11' - 9"
COVERED PORCH
12" 5' - 10" 1' - 5"
7' - 10" 1' - 6"
5 1/2"
8"
8" 9' - 10" 1' - 3"
X07
G02
4' - 0" 12"
20' - 0"
15' - 0"
7 1
1 A
2 7-3/4"
MAX.
X7
BEDROOM
5' - 6"
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:45:23 PM
FLOOR PLANS
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
A3-101
04/14/2026
RECORD SET
A1-201 A3-101 SCALE: 1/4" = 1'-0"
1 GROUND FLOOR PLAN
NO. TYPE
DOOR
WIDTH HEIGHT REMARKS
1 A1 3' - 0" 6' - 8" 1, 2
3 A3 2' - 8" 6' - 8" 1
4 A2 2' - 8" 6' - 8" 1
5 D 3' - 0" 6' - 8"
6 D 3' - 0" 6' - 8"
8 E 2' - 8" 6' - 8"
NO. TYPE
SIZE HEAD
WIDTH HEIGHT HEIGHT REMARKS
1 B 4' - 0" 4' - 0" 6' - 8"
2 B 4' - 0" 4' - 0" 6' - 8"
3 B 4' - 0" 4' - 0" 6' - 8"
4 B 3' - 0" 3' - 0" 6' - 8" 2
5 B 3' - 0" 2' - 0" 6' - 8" 2, 4
6 B 4' - 0" 4' - 0" 6' - 8"
1. REFER TO GENERAL NOTES SHEET G-101 AND G-102 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO STRUCTURAL PLANS FOR FURTHER INFORMATION.
3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION.
4. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
5. REFER TO PLUMBING PLANS FOR FURTHER INFORMATION.
6. ALL FURNITURE AND EQUIPMENT IS BY OWNER AND IS SHOWN FOR COORDINATION PURPOSES ONLY.
7. DIMENSIONS ARE TO FACE OF SHEATHING UNLESS SPECIFICALLY NOTED OTHERWISE.
8. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL
MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS, SHELVING AND BATHROOM FIXTURES.
9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS.
10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO ROUGH DOOR OPENING.
11. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL
ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE MAINTAINED.
12. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS,
PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY OF PARTITION RATING.
13. PER 2025 CRC R318.3 FLOORS OR LANDINGS AT EXTERIOR DOORS SHALL BE
AT LEAST AS WIDE AS DOOR SERVED AND SHALL PROVIDE A LENGTH IN THE DIRECTION OF TRAVEL EQUAL TO 36 INCHES MINIMUM. SLOPE OF EXTERIOR LANDINGS SHALL NOT EXCEED 1/4" PER FOOT (2% SLOPE).
14. PER 2025 CRC 328.1.1 REINFORCEMENT FOR GRAB BARS SHALL BE PROVIDED IN AT LEAST ONE BATHROOM. 1. REINFORCEMENT SHALL BE
SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2X8 INCH NOMINAL LUMBER OR OTHER MATERIAL PROVIDING EQ. HT. AND CAPACITY. REINFORCEMENT ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. 3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED
ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. 4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. 5. BATHTUB AND COMBINATION BATHTUB/SHOWER
REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A
LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. REFER TO SHEET A-903 FOR MORE INFORMATION.
FLOOR PLAN GENERAL NOTES
LEGEND
WINDOW SCHEDULE
DOOR SCHEDULE
KEYNOTES
1. REQUIRED EGRESS WINDOW. REFER TO WINDOW GENERAL NOTE #4 FOR ADDITIONAL INFORMATION.
2. WINDOW INCLUDES BOTH PANES TEMPERED GLAZING.
3. OPTIONAL WINDOW. SEE TITLE SHEET FOR SELECTIONS FOR MORE INFO. AT
LEAST ONE EGRESS OPENING REQUIRED AT ALL BEDROOMS, SEE GENERAL WINDOW NOTE #5 FOR EGRESS REQUIREMENTS.
4. REQUIRED TO PROVIDE OBSCURE / PRIVACY GLASS.
5. @ CASEMENT WINDOWS, INCLUDE BOTH PANES TEMPERED GLAZING.
6. MULLED WINDOW ASSEMBLY
WINDOW REMARKS
1. REFER TO PLANS FOR LOCATION OF DOORS.
2. CONTRACTOR TO VERIFY ROUGH OPENING SIZE WITH DOOR
MANUFACTURER SPECIFICATIONS PRIOR TO CONSTRUCTION.
3. CONTRACTOR TO VERIFY ACTUAL DOOR SIZE TO FIT FINISH OPENING PRIOR TO FABRICATION OF DOOR AND FINISH OPENING.
4. FIRE RATED DOORS SHALL BE SOLID WOOD OR SOLID HONEYCOMB CORE STEEL DOOR 1-3/8" THICK OR COMPLIANT WITH CRC 2025 SECTION R302.5.1.
DOORS SHALL BE SELF-CLOSING AND SELF-LATCHING WITH WEATHER STRIPPING TO BE TIGHT FITTING.
5. EXTERIOR DOORS SHALL EITHER HAVE A FIRE-RESISTANCE RATING OR MUST COMPLY WITH THE FOLLOWING REQUIREMENTS:
A. STILES AND RAILS SHALL NOT BE LESS THAN 1-3/8" THICK.
B. PANELS SHALL NOT BE LESS THAN 1-1/4" THICK, EXCEPT FOR THE
EXTERIOR PERIMETER OF THE PANEL SHALL BE PERMITTED TO TAPER TO A TONGUE OF NOT LESS THAN 3/8" THICK.
6. GLAZING IN DOORS SHALL BE TEMPERED PER CRC 2025 SECTION R324.4.1.
PANES INDICATED IN DOOR LEGEND WITH (T).
7. IF STRUCTURE, IS IN A WUI ZONE OR FHSZ, DOOR MUST COMPLY WITH CWUIC 2025 SEC. 504.9
DOOR GENERAL NOTES
DOOR LEGEND
WINDOW LEGEND
A01 30" WIDE FREE STANDING ELECTRIC RANGE OVEN. VENT TO EXTERIOR, STAINLESS STEEL.
A03 30" WIDE BUILT-IN MICROWAVE WITH RANGE VENT, STAINLESS STEEL.
A04 24" WIDE FRONT CONTROL UNDERCOUNTER DISHWASHER.
A05 REFRIGERATOR LOCATION. PROVIDE 36" SPACE WITH ROUGH PLUMBING FOR ICE MAKER (RECESS IN WALL) OR PER OWNER'S SPECIFICATIONS.
A06 STACKED WASHER/DRYER MACHINE LOCATION. PROVIDE WASTE AND WATER IN RECESSED WALL BOX. PROVIDE DRYER VENT. VENT TO OUTSIDE AIR.
B01 30" SINGLE COMPARTMENT UNDER-MOUNT KITCHEN SINK W/ GARBAGE DISPOSAL. REFER TO WATER EFFICIENCY REQUIREMENTS ON CALGREEN CODE NOTES SHEET.
B04 LAVATORY SINK. REFER TO WATER EFFICIENCY REQUIREMENTS ON CALGREEN CODE NOTES SHEETS.
B05 WATER CLOSET. REFER TO WATER EFFICIENCY REQUIREMENTS ON CALGREEN CODE NOTES SHEETS.
B06 32" x 60" x 72" TUB AND SHOWER COMBINATION. MODEL BY BUILDER.
PROVIDE SHOWER ROD.
B38 MULTI-ZONE HEAT PUMP CONDENSING UNIT. REFER TO PLANS FOR LOCATION OF INDOOR FAN FAN COIL UNITS. REFER TO TITLE 24 FOR ADDITIONAL INFORMATION. PROVIDE CONCRETE PAD MIN. 6" LARGER THAN UNIT IN EACH DIRECTION, 3" MIN. ABOVE GRADE.
C01 SINGLE WOOD SHELF AND POLE.
C08 12" DEEP UPPER CABINET
C10 24" DEEP UPPER CABINET.
C12 34 1/2" HIGH BASE CABINET AND COUNTERTOP.
C13 30" HIGH BASE CABINET AND COUNTERTOP.
G02 CONCRETE FLATWORK. 1/4"/FT SLOPE AWAY FROM BUILDING.
M02 DOWNSPOUT. CONNECT TO STORM DRAIN SYSTEM
X07 PORCH LAYOUT VARIES BY SELECTED STYLE. REFER TO STYLE SPECIFIC PORCH PLANS.
A1-201 A3-101 SCALE: 1/4" = 1'-0"
2 PORCH-SUBURBAN RANCH
A1-201 A3-101 SCALE: 1/4" = 1'-0"
3 PORCH-CRAFTSMAN
A1-201 A3-101 SCALE: 1/4" = 1'-0"
4 PORCH-MEDITERRANEAN
A1-201 A3-101 SCALE: 1/4" = 1'-0"
OPTIONAL SLIDING
5 DOOR @ BEDROOM
NO. TYPE
SIZE HEAD
WIDTH HEIGHT HEIGHT REMARKS
7 A 6' - 0" 5' - 0" 8' - 8" 1, 3
OPTIONAL WINDOWS
NO. TYPE
DOOR
WIDTH HEIGHT REMARKS
X7 C 5' - 0" 6' - 8" 1, 2, 4
OPTIONAL DOORS
1. EXTERIOR DOOR.
2. GLAZING PER DOOR TYPES. REFER TO GENERAL DOOR NOTE #6
3. REQUIRED OPENING OF NOT LESS THAN 100 IN2 FOR MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR BY APPROVED MEANS. [CMC SEC. R504.4.1]
4. VENT DOOR AS REQUIRED PER WATER HEATER MANUFACTURER
REQUIREMENTS / SPECIFICATIONS
5. OPTIONAL DOOR.
DOOR REMARKS
1. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS.
2. CONTRACTOR TO VERIFY EXACT ROUGH OPENING SIZES PRIOR TO FABRICATION OF ROUGH OPENINGS.
3. ALL GLAZING IS DOUBLE PANE UNLESS OTHERWISE NOTED.
4. EGRESS WINDOWS SHALL HAVE A CLEAR OPENING WITH THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44" AFF, MIN. NET CLEAR OPENING FOR EMERGENCY ESCAPE SHALL BE 5.7 S.F. EXCEPT: 5 S.F. MIN. AT GROUND FLOOR. MINIMUM NET CLEAR OPENING DIMENSIONS: HEIGHT: 24", WIDTH: 20". [CRC SEC. R310.2] EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY PER CRC 2025, SECTION 310.1.
5. GLAZING IN WALLS ADJACENT TO BATHTUB / SHOWER WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE SHALL BE SAFETY GLAZING. [CRC SEC. R324.4.5]
6. REFER TO WINDOW SCHEDULE AND WINDOW LEGEND FOR MORE
INFORMATION.
7. IF STRUCTURE IS IN A WUI ZONE OR FHSZ, WINDOW MUST COMPLY WITH CWUIC SECTION 504.8
WINDOW GENERAL NOTES
8. REFER TO ENERGY COMPLIANCE REPORTS TO VERIFY U-FACTOR, SHGC AND ADDITIONAL WINDOW REQUIREMENTS. ALL OPENINGS TO BE
U-FACTOR = (.3) , SHGC = (.23). BUG SCREEN REQUIRED (PER TITLE 24).
PUBLIC SET
FOR USE IN THE CITY OF SAN RAMON
DW
LUXURY VINYL PLANK
(LVT)
FINISH LEGEND
CARPET
(CPT)
CERAMIC TILE
(CT)
CONCRETE
(EC)
KITCHEN LIVING
BATH
HALL
WH
W.I.C.
BEDROOM
COVERED PORCH
STORAGE
A1-201 A3-111 SCALE: 1/4" = 1'-0" 1 GROUND FLOOR FINISH PLAN DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:45:23 PM
FINISH PLANS
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
A3-111
04/14/2026
RECORD SET
FINISH SCHEDULE
1. REFER TO GENERAL NOTES SHEET G-101 AND G-102 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
3. REFER TO PLUMBING PLANS FOR FURTHER INFORMATION.
4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES AND INTERIOR FINISH DETAILS.
5. ALL HARD SURFACE FLOORING SHALL BE SLIP RESISTANT AND MEET THE ANSI A326.3 STANDARD FOR MEASURING THE DYNAMIC COEFFICIENT OF FRICTION (DCOF).
6. ALL FLOORING MATERIALS SHALL COMPLY WITH 2025 CBC SEC. 804.1.
7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2025 CBC TABLE 803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
FINISH PLAN GENERAL NOTES
NAME FLOOR WALL CEILING NOTES
KITCHEN LVT GWB GWB WR GWB BEHIND COUNTER
LIVING LVT GWB GWB
BATH CT WR GWB WR GWB IF CERAMIC TILE IS PROVIDED IN
TUB/SHOWER AREAS, PROVIDE
BACKER BOARDS PER CRC R702.4.2
W.I.C. CPT GWB GWB
WH EC GWB GWB
BEDROOM CPT GWB GWB
HALL LVT GWB GWB
STORAGE EC GWB GWB
PUBLIC SET
FOR USE IN THE CITY OF SAN RAMON
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
C B A
S04
T02
S03
KITCHEN
ATTIC
COVERED PORCH
2' - 6"
ALLOW AIRFLOW
ATTIC ACCESS REQ.
PER CRC R807
OPTIONAL WINDOW
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
1 2 3
LIVING HALL WHW/D
T02
S04
T01
ATTIC
KITCHEN
G14
S03
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
C B A BOTT OF HDR 7' - 6"
K03 L04 K07 L15
M01
M02
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
3 2 1
K11 L15 K13 L15 K05
B38
B18
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
1 2 3 BOTT OF HDR 7' - 6"
L15 K13 K05 K11 L04 K07
H08
21 AD-907
44 AD-907
14 AD-907
± 13' - 3" AD-907
54 AD-907
51 01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
A B C
K05 L04 K07
M01
M02
AD-907
21 LEGEND
3-COAT CEMENT PLASTER
CEMENTITOUS LAP SIDING
CEMENTITOUS BOARD AND BATTEN SIDING
CEMENTITOUS SHINGLE SIDING
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:45:27 PM
EXTERIOR ELEVATIONS &
BUILDING SECTIONS-CRAFTSMAN
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
A3-202
04/14/2026
RECORD SET
KEYNOTES
A3-101 A3-202 SCALE: 1/4" = 1'-0"
6 PLAN 3 - CRAFTSMAN - SECTION 2
A3-101 A3-202 SCALE: 1/4" = 1'-0"
5 PLAN 3 - CRAFTSMAN - SECTION 1
A3-101 A3-202 SCALE: 1/4" = 1'-0"
2 PLAN 3 - CRAFTSMAN - RIGHT
A3-101 A3-202 SCALE: 1/4" = 1'-0"
1 PLAN 3 - CRAFTSMAN - REAR
A3-101 A3-202 SCALE: 1/4" = 1'-0"
3 PLAN 3 - CRAFTSMAN - FRONT
A3-101 A3-202 SCALE: 1/4" = 1'-0"
4 PLAN 3 - CRAFTSMAN - LEFT
B18 ELECTRIC PANEL TBD.
B38 MULTI-ZONE HEAT PUMP CONDENSING UNIT. REFER TO PLANS FOR LOCATION OF INDOOR FAN FAN COIL UNITS. REFER TO TITLE 24 FOR ADDITIONAL INFORMATION. PROVIDE CONCRETE PAD MIN. 6" LARGER THAN UNIT IN EACH DIRECTION, 3" MIN. ABOVE GRADE.
G14 4" CONCRETE SLAB ON GRADE, REFER TO STUCTURAL PLANS H08 ATTIC VENT. PAINT FINISH TO MATCH ROOF COLOR. REFER TO COLORS AND MATERIALS.
K03 ADHERED VENEER SIDING - REFER TO COLOR SCHEME ON COLOR MATERIALS BOARD FOR REFERENCE.
K05 CLASS A ASPHALT COMPOSITE ROOF SHINGLES. GAF TIMBERLINE HD OR APROVED EQUAL. THE USE OF CLASS A TILE ROOFING IS ALSO ALLOWED AND HAS BEEN ACCOUNTED FOR IN STRUCTURAL ROOF LOADS.
K07 FIBER CEMENT SHINGLE SIDING - REFER TO COLOR SCHEME ON COLOR MATERIALS BOARD ON SHEET G-110 & G-111.
K11 DOOR PER PLAN
K13 WINDOW PER PLAN
L04 2x12 FASCIA. PRIME ALL SIDES.
L15 WIN/DOOR SURROUNDS
M01 GUTTER. CONNECT TO DOWNSPOUT. PROVIDE MEANS TO PREVENT ACCUMULATION OF LEAVES AND DEBRIS IN GUTTER PER CRC R327.5.4 M02 DOWNSPOUT. CONNECT TO STORM DRAIN SYSTEM
S03 ROOF INSULATION. REFER TO TITLE 24 (R-38 MIN.).
S04 2X6 WALL INSULATION. REFER TO TITLE 24 (R-21 MIN.)
T01 2X4 WOOD STUD WALL. REFER TO STRUCTURAL.
T02 2X6 WOOD STUD WALL. REFER TO STRUCTURAL.
1. REFER TO GENERAL NOTES SHEET G-101 & G-102 FOR ADDITIONAL
REQUIREMENTS
2. SEE DETAILS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
3. REFER TO ROOF PLAN FOR OVERHANGS. FASCIA PER DETAILS. PROVIDE ALUMINUM GUTTER. SEE ROOF PLAN FOR APPROXIMATE DOWNSPOUT LOCATIONS, U.N.O.
4. REFER TO DOOR AND WINDOW SCHEDULES AND TYPES FOR DOOR AND WINDOW INFORMATION.
5. THE NOMINAL THICKNESS AND ATTACHMENT OF EXTERIOR WALL COVERINGS SHALL BE IN ACCORDANCE WITH 2025 CRC TABLE R703.3(1).
6. GYPSUM SHEATHING SHALL BE ATTACHED TO EXTERIOR WALLS IN ACCORDANCE WITH 2025 CRC TABLE R602.3 (1).
7. CLADDING ATTACHMENT OVER FOAM SHEATHING TO WOOD FRAMING IN ACCORDANCE WITH 2025 CRC R703.15. REFER TO 2025 CRC R703.8 FOR
ANCHORED MASONRY OR STONE VENEER INSTALLED OVER FOAM
SHEATHING.
ELEVATION GENERAL NOTES
1. THE PURPOSE OF THESE DRAWINGS IS TO SHOW CONSTRUCTION MATERIALS/ASSEMBLIES. FOR SPECIFIC SIZES AND DETAILS REFER TO ARCHITECTURAL PLANS, ELEVATIONS, DETAILS, AND STRUCTURAL PLANS. *KEYNOTES ONLY APPLY IF REFERENCED ON PLANS.
2. WALL ASSEMBLIES TO BE PER FLOOR PLAN.
3. DOORS AND WINDOWS TO BE PER APPLICABLE SCHEDULE. REFER TO FLOOR PLANS FOR IDENTIFICATION.
4. INSULATION: REFER TO TITLE 24 REPORT AND "INSULATION" NOTES ON SHEET FOR ADDITIONAL RATINGS, REQUIREMENTS, AND INFORMATION.
5. FIREBLOCKING TO BE LOCATED PER 2025 CRC SECTION R302.11:
A. SECTION R302.11 -
1. FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF
STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND
PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS:
1. VERTICALLY AT CEILING AND FLOOR LEVELS
2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET.
2. AT INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND
HORIZONTAL SPACES SUCH AS SOFFITS, DROP CEILINGS AND COVE CEILINGS.
3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS
SHALL COMPLY WITH 2025 CRC SECTION R302.7.
4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT
CEILINGS AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO
RESIST THE FREE PASSAGE OF FLAME PRODUCTS OF COMBUSTION.
THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE
REQUIRED TO MEET THE ASTM E136 REQUIREMENTS.
5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE 2025 CRC SECTION R1003.19.
6. FIREBLOCKING OF CORNICES OF A TWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING-UNIT SEPARATION.
B. SECTION R302.11.1 - FIREBLOCKING MATERIALS SHALL CONSIST OF FOLLOWING MATERIALS:
1. TWO-INCH NOMINAL LUMBER
2. TWO THICKNESSES OF ONE-INCH NOMINAL LUMBER WITH BROKEN
LAP JOINTS
3. THE THICKNESS OF 0.719-INCH WOOD STRUCTURAL PANELS WITH JOINTS BACKED BY 0.719-INCH WOOD STRUCTURAL PANELS
4. THE THICKNESS OF 0.75-INCH PARTICLE BOARD WITH JOINTS BACKED BY 0.75-INCH PARTICLE BOARD
5. ONE-HALF-INCH GYPSUM BOARD
6. ONE-FOURTH-INCH CEMENT-BASED MILLBOARD
7. BATTS OR BLANKETS OF MINERAL WOOL, MINERAL FIBER OR OTHER
APPROVED MATERIAL INSTALLED IN SUCH A MANNER AS TO BE
SECURELY RETAINED IN PLACE
8. CELLULOSE INSULATION INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263, FOR THE SPECIFIC APPLICATION.
6. PER 2025 CRC SECTION R304.1 SLEEPERS AND SILLS ON A CONCRETE OR
MASONRY SLAB THAT IS IN DIRECT CONTACT WITH GROUND, UNLESS
SEPARATED BY AN IMPERVIOUS MOISTURE BARRIER SHALL BE NATURALLY
DURABLE OR PRESERVATIVE-TREATED WOOD IN ACCORDANCE WITH AWPA U1.
7. REFER TO RCP'S FOR SOFFIT DIMENSIONS AND FURTHER INFORMATION.
8. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG EQUIPMENT AND FIXTURES OCCUR.
9. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2025 CRC 302.9 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
SECTIONS GENERAL NOTES
PUBLIC SET
FOR USE IN THE CITY OF SAN RAMON
(ALL STYLES)
*OWNER/APPLICANT REQ. TO SELECT ONE OPTION FOR ALL OF THE FOLLOWING AND MARK THROUGH NON-APPLICABLE OPTIONS AND DETAILS THROUGHOUT SET:
MEDITERRANEAN
WATER HEATER
(B) ALTERNATIVE WATER HEATER WITH STIPULATION THAT NEW T24 ENERGY REPORT IS PROVIDED. MFR. & MODEL:______________________________________ (A) NORTHWEST ENERGY EFFICIENCY ALLIANCE (NEEA) RATED HEAT PUMP WATER HEATER; SPECIFIC BRAND/MODEL MUST BE INSTALLED (PER TITLE 24). *OWNER OR APPLICANT TO SELECT (1) OF THE (3) FOLLOWING STYLES (BELOW) AND ONE OF EACH OF THE SUBSEQUENT OPTIONS THEREIN. FOR CLARITY, CROSS OUT OTHER STYLES AND STYLE OPTIONS THROUGHOUT THE ENTIRE DRAWING SET.
ELECTRICAL PANEL (SEE PLANS & SITE PLAN FOR LOCATION)
(B) A NEW ELEC. SUBPANEL CONNECTS TO THE ELEC. MAIN PANEL OF 220 AMP ON THE PRIMARY HOME WITH A 225 AMP MIN. BUSBAR RATING
(A) NEW ELEC. MAIN PANEL OF 200 AMP MIN. WITH 225 AMP MIN. BUSBAR RATING (C) NEW ELEC. MAIN PANEL MIN. 400 AMP DUAL METER AT PRIMARY HOUSE WITH A NEW ELEC. SUB-PANEL AT ADU THAT CONNECTS TO THE MAIN PANEL OPTIONAL SLIDING DOOR @ KITCHEN/LIVING
(B) NO; WINDOW 7 TO REMAIN
(A) YES; REPLACE W/ DOOR X7
(A) EXT. TOUNGE & GROOVE
(B) FIBER CEMENT
(C) EXT. GRADE PLYWOOD
EXTERIOR EAVES, RAKES, & SOFFITS MATERIAL SELECTION
STYLE-BASED OPTIONS
OPTION SELECTION
EXTERIOR TRIM ELEMENTS
(A) FIBER CEMENT
(B) EXT. GRADE WOOD
BASE TRIM
(A) YES
(B) NO
NO EXTRA STYLE-BASED OPTIONS TO SELECT FOR THIS STYLE
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt4/20/2026 11:15:48 AM TITLE SHEET - PLAN 3 -
MEDITERRANEAN
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
G-007
04/14/2026
PUBLIC SET
GENERAL
G-007 TITLE SHEET - PLAN 3 - MEDITERRANEAN
G-101 GENERAL NOTES
G-102 GENERAL NOTES, ABBREVIATIONS, & SYMBOLS
G-201 CAL GREEN RESIDENTIAL MANDATORY MEASURES
G-202 CAL GREEN RESIDENTIAL MANDATORY MEASURES
ENERGY COMPLIANCE
T24-000 ENERGY MANDATORY REQUIREMENTS
T24-005 ENERGY COMPLIANCE REPORT - PLAN 3
T24-006 ENERGY COMPLIANCE REPORT - PLAN 3
ARCHITECTURAL SITE
AS-101 EXAMPLE SITE PLAN
AS-102 ARCHITECTURAL SITE PLAN
ARCHITECTURAL
A3-101 FLOOR PLANS
A3-112 ELECTRICAL & MECHANICAL PLANS
A3-121 ROOF PLANS & REFLECTED CEILING PLANS-MEDITERRANEAN A3-201 EXTERIOR ELEVATIONS & BUILDING SECTIONS-MEDITERRANEAN A3-111 FINISH PLANS
ARCHITECTURAL DETAILS
AD-901 ARCHITECTURAL DETAILS - COMMON - FLASHING
AD-902 ARCHITECTURAL DETAILS - COMMON
AD-903 ARCHITECTURAL DETAILS - COMMON - ROOF
AD-904 ARCHITECTURAL DETAILS - AGING-IN-PLACE
AD-905 ARCHITECTURAL DETAILS - MEDITERRANEAN
AD-906 ARCHITECTURAL DETAILS - MEDITERRANEAN
AD-911W ARCHITECTURAL DETAILS - S-TILE ROOF - WUI
STRUCTURAL
S-101 SHEET INDEX, ABBREVIATIONS, & SYMBOLS
S-102 GENERAL NOTES
S-103 GENERAL NOTES, SPECIAL INSPECTION & TESTS
S-201 PIER FOUNDATION & ROOF FRAMING PLANS - STICK
S-202 PIER FOUNDATION & ROOF FRAMING PLANS - TRUSS
S-301 TYPICAL CONCRETE DETAILS
S-302 TYPICAL CONCRETE DETAILS
S-311 CONCRETE DETAILS
S-401 TYPICAL WOOD DETAILS
S-402 TYPICAL WOOD DETAILS
S-403 TYPICAL WOOD DETAILS
S-404 TYPICAL WOOD DETAILS
S-421 ROOF FRAMING DETAILS
S-422 ROOF FRAMING DETAILS
S-431 ROOF FRAMING DETAILS
Grand total: 37
SQUARE FOOTAGE CONDITIONED?
ADU-PLAN 3 720 SF CONDITIONED
COVERED PORCH-PLAN 3 183 SF UNCONDITIONED
STORAGE-PLAN 3 8 SF UNCONDITIONED
PROJECT DIRECTORY PROJECT INFORMATION
UTILITIES
SHEET INDEX
ADDRESS:
CONTACT:
EMAIL:
PHONE:
RRM DESIGN GROUP
3765 S HIGUERA ST, SUITE 102
SAN LUIS OBISPO, CA 93401
P:(805) 543-1794
ARCHITECT
RANDY RUSSOM
[email protected]
USER LICENSE AGREEMENT
SIGNATURE DATE
VICINITY MAP (TO BE PROVIDED BY OWNER OR APPLICANT)
WATER AND SEWER SERVICE _________________________________________
ELECTRICAL SERVICE
GAS SERVICE
SEWER SERVICE
GARBAGE SERVICE
CABLE SERVICE
_________________________________________
_________________________________________
_________________________________________
_________________________________________
_________________________________________
(TO BE PROVIDED BY APPLICANT OR OWNER)
*FOR BUILDING DEPARTMENT REVIEW, INITIAL WHEN SECTION HAS BEEN REVIEWED
1. 2.
3. ANY PROPOSED ENERGY STORAGE SYSTEM (ESS) SHALL FOLLOW SINGLE-FAMILY RESIDENTIAL MANDATORY REQ. SUMMARY SECTION 150.0(s) AND WILL REQUIRE A SEPARATE PERMIT TO BE PULLED BY APPLICANT.
VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION (VERIFICATION DETAILS FROM VCHP STAFF REPORT, APPENDIX B, AND RA3) (PER TITLE 24).
THIS PLAN IS INTENDED FOR FLAT LOTS (SLOPING LESS THAN 10" ACROSS THE
LONGEST BUILDING DIMENSION), WITHOUT HIGHLY EXPANSIVE OR LIQUEFIABLE
SOILS, WHERE THE MAIN DWELLING UNIT IS SUPPORTED IN SHALLOW FOOTINGS WITH SLABS ON GRADE CONSTRUCTION. IF THE PROJECT SITE DEVIATES FROM ANY
OF THE AFOREMENTIONED QUALITIES, AS DETERMINED BY THE BUILDING OFFICIAL,
THERE PRE-APPROVED ADU FOUNDATION PLANS AND DETAILS ARE NOT APPLICABLE.
ADDITIONAL INFORMATION:
IS THE ADU 5' - 0" OR LESS TO ANY PROPERTY LINE AND/OR IS THE ADU 10' - 0" OR LESS FROM ANY ADJACENT BUILDING OR STRUCTURE?
NO
SUPPORTING DOCUMENTS
PREPARED BY:
DATE PREPARED:
JOB NUMBER:
CARSTAIRS ENERGY
ENERGY COMPLIANCE
FEBRUARY 13, 2026
26-01086
PLEASE PROVIDE THE WASTE RECYCLE FORM FILLED OUT AND SIGNED PRIOR TO ISSUANCE. THE OWNER/APPLICANT/CONTRACTOR/PERSON DOING THE WORK IS REQUIRED TO RECYCLE 75% OF ALL PROJECT CONSTRUCTION AND DEMOLITION DEBRIS.
UTILITY, GRADING, AND DRAINAGE PLAN TO BE PROVIDED BY OTHERS. •
•
•
•
•
•
•
•
HERS VCHP: HERS RATER WILL NEED TO FOLLOW THE VERIFICATION AND TESTING
PROTOCOL FOR THE VARIABLE CAPACITY HEAT PUMP CREDIT REQUIREMENTS,
INCLUDING BUT NOT LIMITED TO, VERIFIED REFRIGERANT CHARGE, VERIFIED MINIMUM HSPF AND EER/SEER, AND CAPACITY; DUCTLESS INDOOR UNITS AND THE COMPONENTS ARE WITHIN THE CONDITIONED ENVELOPE; AND AIRFLOW PROVIDED TO ALL HABITABLE SPACES (BEDROOMS AND LIVING SPACE).
THE FOLLOWING IS A SUMMARY OF THE FEATURES THAT MUST BE FIELD-VERIFIED BY
A CERTIFIED HERS RATER AS A CONDITION FOR MEETING THE MODELED ENERGY PERFORMANCE OF THIS COMPUTER ANALYSIS. REGISTERED CF2RS AND CF3RS ARE REQUIRED TO BE COMPLETED IN THE HERS REGISTRY.
QUALITY INSULATION INSTALLATION (QII)
INDOOR AIR QUALITY VENTILATION
KITCHEN RANGE HOOD
VERIFIED REFRIGERANT CHARGE
AIRFLOW IN HABITABLE ROOMS (SC3.1.4.1.7)
VERIFIED HEAT PUMP RATED HEATING CAPACITY
WALL-MOUNTED THERMOSTAT IN ZONES GREATER THAN 150 FT2 (SC3.4.5)
DUCTLESS INDOOR UNITS LOCATED ENTIRELY IN CONDITIONED SPACE (SC3.1.4.1.8)
HERS QII REQUIRED
OWNER/APPLICANT HAS COMPLETED SPECIAL INSPECTION FORM
OWNER/APPLICANT SIGNATURE: _____________________________ SEE SHEET S-103 FOR REQUIRED SPECIAL INSPECTIONS
A REGISTERED DESIGN PROFESSIONAL SHALL COMPLETE THE CITY OF SAN RAMON STATEMENT OF REQUIRED SPECIAL INSPECTIONS CERTIFICATE (FORM PLG-240) PRIOR TO PERMIT ISSUANCE. IDENTIFY THE TYPE OF WORK REQUIRING SPECIAL
INSPECTIONS IN THE PLANS AND THE INDIVIDUALS OR FIRMS RESPONSIBLE FOR THE SPECIAL INSPECTION ELEMENT(S). FOR FURTHER INSTRUCTIONS SEE S-103.
SPECIAL INSPECTIONS REQ'D
OWNER/APPLICANT SIGNATURE:____________________________
OWNER/APPLICANT TO SIGN USER AGREEMENT BELOW:
BY USING THESE PERMIT READY ACCESSORY DWELLING UNIT CONSTRUCTION
DOCUMENTS, THE USER AGREES TO RELEASE, HOLD HARMLESS, AND INDEMNIFY
THE CITY OF SAN RAMON, ITS ELECTED OFFICIALS AND EMPLOYEES, RRM DESIGN
GROUP, AND THE ARCHITECT OR ENGINEER WHO PREPARED THESE
CONSTRUCTION DOCUMENTS FROM ANY AND ALL CLAIMS, LIABILITIES, SUITS AND
DEMANDS ON ACCOUNT OF ANY INJURY, DAMAGE OR LOSS TO PERSONS OR
PROPERTY, INCLUDING INJURY OR DEATH, OR ECONOMIC LOSSES, ARISING OUT OF THE USE OF THESE CONSTRUCTION DOCUMENTS.
THE PLANS ATTACHED HERE ARE APPROVED FOR ONLY USE IN CITY OF SAN RAMON. NO DEVIATIONS, ALTERATIONS, OR OPTIONS BEYOND THOSE
SPECIFICALLY INDICATED IN THE PLANS ARE ALLOWED WITHOUT PRIOR APPROVAL BY THE ISSUING JURISDICTION AND CHIEF BUILDING OFFICIAL. ANY
UNAPPROVED PLAN MODIFICATIONS MAY BE DEVELOPED THROUGH RRM DESIGN GROUP AND THE APPROVING JURISDICTION IF REQUIRED. THIS SET OF PLANS SHALL NOT BE USED FOR A PUBLIC HOUSING PROJECT.
YES; IF YES, FIRE RATED WALL, ROOF & PROJECTIONS REQUIRED PER 2025 CBC, CHAPTER 2. FIRE RATED WALL DETAIL: 54/A-902. FIRE RATED ROOF DETAIL: 22/A-903
IF YES, FIREBLOCKING IS REQUIRED IN PROJECTIONS, RAKES AND EAVES.
SEE DETAILS: 41/A-905, 42/A-905, 41/A-907, 42/A-907, 41/A-909, & 42/A-909 (TO BE PROVIDED BY
OWNER / APPLICANT)
APPLICANT:
ADDRESS:
CONTACT:
EMAIL:
PHONE:
OWNER:
ADDRESS:
CONTACT:
EMAIL:
PHONE:
SITE INFORMATION:
APN:
ZONING:
REAR: 4' - 0" (A.B. NO. 86)
FRONT:
SIDES: 4' - 0" (A.B. NO. 86)
SETBACKS
_____________
_____________
_____________
REQUIRED: PROPOSED:
SETBACK RESTRICTIONS - FIRE RATINGS:
WASTE WATER:
SEWER
*FOR BUILDING DEPARTMENT REVIEW, INITIAL WHEN SECTION HAS BEEN REVIEWED
STAFF INITIALS
BUILDING INFORMATION:
CONSTRUCTION TYPE: VB
MAX HEIGHT ALLOWED: 16' - 0"
ZONING:
SPRINKLERED: (SEE FIRE SPRINKLER
SECTION ON THIS SHEET)
MAX HEIGHT PROPOSED:
NUMBER OF STORIES: 1 OCCUPANCY GROUP: R-3
PROJECT ADDRESS: _________________________________________________________________________________
SEPARATE PERMITS DEFERRED SUBMITTAL
SOLAR PV SYSTEM TRUSS CALCULATIONS
PROJECT SCOPE:
1. 2.
CONSTRUCTION OF A NEW DETACHED 1 STORY 708 SF ACCESSORY DWELLING UNIT WITH 1 BEDROOMS AND 1 BATH.
ALL THE WORK SHOWN IN THE DRAWINGS AND SPECIFICATIONS.
YES, PV SYSTEM REQUIRED
NO, PV NOT REQUIRED (FOR ADUS 652 SF OR SMALLER) PER CALIFORNIA ENERGY CODE SECTION 150.1(C)14 EXCEPTION (IF NO, OWNER/APPLICANT REQ.
TO SELECT ONE):
1) FOR STEEP SLOPE ROOFS, WITH NORTHERLY AZIMUTH THAT LIES BETWEEN 300 DEGREES AND 90 DEGREES FROM TRUE NORTH. IF THE SARA IS LESS THAN 80 CONTIGUOUS SQUARE FEET.
2) PV SYSTEM SIZE SPECIFIED BY SECTION 150.1(C)14 IS LESS THAN 1.8 KWDC. 3) BUILDINGS W/ APPROVED ROOF DESIGNS, WHERE THE ENFORCEMENT
AUTHORITY DETERMINES IT IS NOT POSSIBLE FOR THE PV SYSTEM 4) FOR BUILDINGS THAT ARE APPROVED BY THE LOCAL PLANNING DEPARTMENT PRIOR TO JANUARY 1, 2020 WITH MANDATORY CONDITIONS FOR APPROVAL. 5) PV SYSTEM SIZES DETERMINED USING EQUATION 150.1-C MAY BE REDUCED BY 25 PERCENT IF INSTALLED IN CONJUNCTION WITH A QUALIFYING BATTERY STORAGE SYSTEM.
OTHER, (REQ. APPROVAL) SPECIFY:_________________________________________ SOLAR READY REQUIREMENTS SHALL BE IMPLEMENTED. FOR MORE INFORMATION SEE "SOLAR READY NOTES" ON SHEET G-102.
PHOTOVOLTAIC SYSTEM (PV)
*SEPARATE SUBIMTTAL
SAN RAMON PROTOTYPE ACCESSORY DWELLING UNIT - PLAN 3 - MEDITERRANEAN +/- 11'-4"
SIGNATURE DATE
1. 2.
3. 4.
5. 6.
7. DETAILED SPRINKLER PLANS SHALL BE SUBMITTED TO THE FIRE PREVENTION BUREAU AND APPROVED PRIOR TO INSTALLATION. PLANS AND INSTALLATION MUST BE BY A C16 LICENSED SPRINKLER CONTRACTOR.
SECTION 903.3.1.3 NFPA 13D SPRINKLER SYSTEMS AUTOMATIC FIRE SPRINKLER SYSTEMS INSTALLED IN ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3.
SECTION 903.2.8 GROUP R AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3 SHALL BE PROVIDED THROUGHOUT ALL BUILDINGS WITH A GROUP R FIRE AREA.
SECTION 903.2.8.1 GROUP R-3 AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.3 SHALL BE PERMITTED IN GROUP R-3 OCCUPANCIES.
LOCATION AND SIZE OF WATER SERVICE UNDERGROUND SHALL BE INSTALLED AS SHOWN ON APPROVED FIRE SPRINKLER PLANS. A MINIMUM 1 INCH WATER SHALL BE INSTALLED.
A FIRE UNDERGROUND FLUSH CERTIFICATION SHALL BE REQUIRED AT FINAL INSPECTION.
A HYDRO INSPECTION OF THE FIRE SPRINKLER SYSTEM IS REQUIRED PRIOR TO FRAME INSPECTION. ONLY THE NEW PIPING SHALL BE TESTED.
FIRE PROTECTION
FIRE SPRINKLERS (WHEN REQUIRED) NOTES:
DOES THE PRIMARY RESIDENCE HAVE NFPA 13D SPRINKLERS?
NO: THEREFORE, THE PROPOSED ADU IS NOT REQUIRED TO BE SPRINKLERED YES: THEREFORE, THE PROPOSED ADU IS REQUIRED TO BE SPRINKLERED (TO BE PROVIDED BY
OWNER / APPLICANT)
1. 2.
3. PORTIONS OF THE CITY OR COUNTY ARE LOCATED WITHIN THE WILDLANDURBAN INTERFACE. TO DETERMINE IF YOUR STRUCTURE IS LOCATED IN A WUI FIRE AREA PLEASE VISIT THE U.S. FIRE ADMINISTRATION WEBSITE:
HTTPS://SRVFIRE.MAPS.ARCGIS.COM/APPS/WEBAPPVIEWER/INDEX.HTML? ID=D55B2C2388A14733AD7FE72E86C0693E
IS YOUR STRUCTURE IN A WUI FIRE AREA?
YES NO
IF YOUR STRUCTURE IS LOCATED IN THE WUI FIRE AREA (EMBER ZONE OR
IGNITION ZONE), ALL CONSTRUCTION OF THE ADU STRUCTURE MUST COMPLY WITH THE CWUIC 504.
THIS PROTOTYPE PLAN PROVIDES DESIGNS THAT COMPLY WITH THE PROVISIONS REQUIRED BY THE CWUIC 504. PLEASE SEE APPLICABLE DETAIL SHEET(S): A-911
WILDLAND-URBAN INTERFACE FIRE AREA (WUI):
FIRE SPRINKLERS:
ADDRESS:
CONTACT:
EMAIL:
PHONE:
RRM DESIGN GROUP
3765 S HIGUERA ST, SUITE 102
SAN LUIS OBISPO, CA 93401
P:(805) 543-1794
STRUCTURAL
JESSICA MEADOWS
[email protected] FOR USE IN THE CITY OF SAN RAMON
SITE PLAN LEGEND
EASTMENT
SETBACK
PROPERTY LINE
(E) STREET NAME
OVERALL DIMENSION OF EXISTING RESIDENCE
XX' - XX"
4' - 0" MIN. SETBACK
XX' - XX" XX' - XX" XX' - XX"
OVERALL DIMENSION OF EXISTING RESIDENCE
XX' - XX" XX' - XX"
OVERALL DIMENSION OF NEW ADU
XX' - XX"
XX' - XX" FROM ADU TO (E) RESIDENCE
OVERALL DIMENSION OF EXISTING RESIDENCE
XX' - XX" XX' - XX"
XX'-XX" (DISTANCE)
(E) SINGLE FAMILY
RESIDENCE EXAMPLE
(ADDRESS)
(FOOTPRINT SF)
(N) ACCESSORY
DWELLING UNIT
EXAMPLE
SXX° XX'X"E
XX'-XX" (DISTANCE)
NXX° XX'X"W
NXX° XX'X"W (PROPERTY LINE BEARINGS)
XX'-XX" (DISTANCE)
SXX° XX'X"E
SETBACK
MIN 4'
MIN 4' - 0" SETBACK
XX' - XX"
MIN. 5' - 0" MIN. 5' - 0"
(E) PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
XX'-XX" (DISTANCE)
(E) SIDEWALK
EXAMPLE
(E) PROPERTY LINE
MIN. 4' - 0" SETBACK
XX' - XX"
(E) RETAINING WALL EXAMPLE
(DISTANCE FROM PROPERTY LINE TO (E) RESIDENCE
XX' - XX"
X XX X X X X X
(N) MECHANICAL EQUIPMENT LOCATION
EXAMPLE; NOT LESS THAN 30" OF
CLEARANCE IN WIDTH, DEPTH, & HEIGHT
SHALL BE PROVIDED TO ACCESS THE
EQUIPMENT. (2025 CMC SECTION 304.1)
(N) APPLICANT TO ILLUSTRATE AND
ANNOTATE PROPOSED APRONS,
LANDINGS, PORCHES, OVERHANGS, MECH.
/ ELEC. ITEMS AND PROPOSED ACCESS
POINTS
LOCATE ELECTRICAL (ALL) PANELS
SEE TITLE SHEET FOR PANEL OPTIONS AND
MAXIMUM AMPERAGE FOR THE PROPOSED ADU.
(E) EXISTING SWIMMING POOL
EXAMPLE (OWNER / APPLICANT
TO PROVIDE SF)
EASEMENT
EXAMPLE
(ANY/ALL
SHALL
BE
SHOWN)
SETBACK
XX' - XX"
XX' - XX"
MIN. 10'
(N) ASSUMED PROPERTY LINE
(E) SETBACK
(E) SETBACK
(E) SETBACK
XX'-XX" SETBACK
DISTANCE OF NEAREST POINT OF ADU TO CENTERLINE OF
IMAGINARY LINE BETWEEN THE TWO BUILDINGS (UNDER 5' - 0" 1- HOUR FIRE-RATED WALL AND 1-HOUR FIRE-RATED EAVE REQUIRED).
DISTANCE OF NEAREST POINT OF ADU TO
ADJACENT PROPERTY LINE (WHEN UNDER
5' - 0," 1-HOUR FIRE-RATED WALL AND 1-
HOUR FIRE-RATED RAKE/EAVE REQUIRED).
(FOOTPRINT SF)
PROVIDE ALL DIMENSIONS FOR
ALL (E) AND/OR (N) PAVED AREAS
PROVIDE ALL DIMENSIONS, OF (E) DRIVEWAY(S)
XX' - XX"
XX' - XX"
XX' - XX"
XX' - XX"
(E) FENCE EXAMPLE
(PROVIDE DIMENSIONS)
(E) FENCE EXAMPLE
(PROVIDE DIMENSIONS)
XX
(E) SIDEWALK
EXAMPLE
(CENTERLINE OF STREET)
OWNER/APPLICANT TO
INDICATE MAIN ENTRANCE
SITE PLAN CHECKLIST
DRAWING SCALE - SITE PLAN SHOULD BE DRAWN TO A MEASURABLE SCALE.
PROPERTY LINES
SHOW OUTLINE OF PROPERTY USING DASHED LINE IN LEGEND. INDICATE THE BEARING AND DISTANCE OF THE PROPERTY LINE.
LABEL YARDS
LABEL FRONT, REAR, SIDE YARDS, AS WELL AS DRIVEWAYS, PATHWAYS AND ANY OTHER HARDSCAPE.
SETBACKS
DIMENSION THE DISTANCE BETWEEN BUILDINGS AND PROPERTY LINES, AS WELL AS BUILDINGS TO OTHER STRUCTURES. SETBACKS TO SIDE AND REAR PROPERTY SIDE SHALL BE A MINIMUM OF (4' - 0").
EASEMENTS
REFER TO LEGEND. MUST INCLUDE ALL APPLICABLE EASEMENTS.
PROPOSED STRUCTURE SHALL COMPLY WITH EASEMENT REQUIREMENTS.
PROVIDE THE EXACT LOCATION AND LABEL ALL OF THE EXISTING & PROPOSED
UTILITIES ON THE SITE PLAN
A. THIS INCLUDES BUT IS NOT LIMITED TO UTILITIES, POLES, SEPTIC, SEWER, DRAINS, ELECTRICAL, GAS METERS, LINES, AND ANY PHOTOVOLTAIC.
B. INDICATE SEWER ELEVATION OF LATERAL AND MAIN CONNECTION.
IF ON SEPTIC SYSTEM, PROVIDE DEPARTMENT OF ENVIRONMENTAL
HEALTH (DEH) EXHIBIT WITH LEACH LINES SHOWN AND AREA FOR NEW LEACH LINES. SEWER MAIN EXTENSION MAY BE REQUIRED. INCLUDE
LOCATIONS AND ALL ELEVATIONS OF PROPOSED SEPTIC / SEWER / LEACH LINES. PROVIDE INVERT ELEVATIONS AT CLEANOUT, SEWER MAIN
CONNECTION, ADU CONNECTION, AND AT ANY OTHER CONNECTION POINTS.
C. PLEASE SPECIFY ON THE PLANS IF THE ADU WILL HAVE NEW
INDEPENDENT SERVICES DIRECTLY FROM THE PUBLIC RIGHT OF WAY
CONNECTION OR IF THE SERVICES WILL BE BRANCHED OFF THE EXISTING MAIN LINES ON THE PROPERTY.
D. JUSTIFY PIPE SIZES SHOWN ON THE PLAN ARE ADEQUATE FOR THE PROPOSED ADU SERVICES. IF THE SERVICES ARE CONNECTED TO THE
EXISTING MAIN SERVICES, THEN PROVIDE JUSTIFICATION THAT THE
EXISTING MAINS CAN HANDLE THE NEW INCREASED FLOWS OF THE ADU FOR WATER SUPPLY AND SANITARY SEWER SYSTEMS. PLEASE USE CPC TABLE 610.3, TABLE 610.4, AND SECTION 610.5 FOR JUSTIFICATION. NOTE,
IF USING APPENDIX A SIZING CRITERIA, PLEASE INCLUDE THE CPC APPENDIX A CHART ON THE PLAN.
LABEL STREETS & SIDEWALKS
FOOTPRINT OF PROPOSED ADU - REFER TO LEGEND FOR FOOTPRINT AT 10'=1" SCALE
DIMENSION BUILDING SEPARATION
DIMENSION THE DISTANCE BETWEEN THE PROPOSED ADU AND ANY
EXISTING STRUCTURES
AREA OF EXISTING BUILDING - INDICATE THE SQUARE FOOTAGE OF THE EXISTING HOUSE.
LOCATION OF RAIN WATER LEADERS - THE ROOF DRAINS SHOULD DRAIN AWAY FROM THE PROPERTY LINES AND INTO THE LANDSCAPE AREA.
SCALE:
1 EXAMPLE SITE PLAN /10" = 1' - 0"
SWIMMING POOLS - ALL EXISTING SWIMMING POOLS SHALL BE SHOWN ON THE SITE PLAN AND SHALL HAVE 10' MINIMUM SETBACK TO THE NEW ADU STRUCTURE.
FOOTPRINT OF ALL EXISTING AND PROPOSED BUILDINGS - PLOT THE
PROPOSED ADU BUILDING FOOTPRINT ALONG WITH ANY OTHER EXISTING BUILDINGS ONSITE. THIS INCLUDES ALL STRUCTURES / PORCHES / GAZEBOS.
PLOT ANY OPTIONAL COVERED PATIOS (WHEN SELECTED).
NORTH ARROW
PORCHES - THERE SHALL BE NO MORE THAN 30 INCHES MEASURED
VERTICALLY TO THE FLOOR OR GRADE BELOW (INCLUDING FLOORS, STAIRS, RAMPS, AND LANDINGS) ANYWHERE MEASURED LESS THAN 36 INCHES HORIZONTALLY TO THE EDGE OF THE PORCH/SLAB/SURFACE OF THE RAIL.
INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD.
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS
2. REFER TO STRUCTURAL PLANS FOR FURTHER INFORMATION
3. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY PER 2025 CRC, SECTION 308.1.
4. NOT LESS THAN 30" OF CLEARANCE IN WIDTH, DEPTH, & HEIGHT SHALL BE PROVIDED TO ACCESS EXTERIOR MECHANICAL EQUIPMENT. SHOW
LOCATION ON SITE PLAN & LABEL (2025 CMC SECTION 304.1 & 2025 CPC 504.3).
5. PROPOSED ADU IS TO BE FULLY ELECTRIC. INSTALLATION OF A GAS LINE TO THE PROPOSED ADU WILL NOT BE PERMITTED.
6. CALL BEFORE YOU DIG! CONTACT UNDERGROUND SERVICE ALERT (USA) AT 1-800-227-2600 AT LEAST 2 WORKING DAYS BEFORE EXCAVATING.
7. UNLESS OTHERWISE NOTED ON THE PLANS, FINISHED GROUND SURFACES SHALL BE GRADED TO DRAIN THE FINISHED SITE PROPERLY WITHIN 10-FEET OF ANY BUILDING FOUNDATION WITH A SLOPE OF 5% AWAY FROM ANY BUILDING OR STRUCTURE. ALL EXTERIOR HARDSCAPE WITHIN 10-FEET OF A BUILDING FOUNDATION SHALL BE INSTALLED WITH A 2% MINIMUM SLOPE AWAY FROM ANY BUILDING OR STRUCTURE. DRAINAGE SWALES SHALL BE A
1.5% MINIMUM SLOPE. ALL GRADED SLOPES SHALL HAVE A MAXIMUM SLOPE OF 3H TO 1V (33%), UNLESS SHOWN OTHERWISE ON THE PLANS.
8. LOT GRADING SHALL CONFORM AT THE PROPERTY LINES AND SHALL NOT
SLOPE TOWARD PROPERTY LINES IN A MANNER WHICH WOULD CAUSE STORM WATER TO FLOW ONTO NEIGHBORING PROPERTY. HISTORIC
DRAINAGE PATTERNS SHALL NOT BE ALTERED IN A MANNER TO CAUSE DRAINAGE PROBLEMS TO NEIGHBORING PROPERTY.
9. NEW RAINWATER DOWNSPOUTS SHALL BE DISCONNECTED AND DIRECT RUNOFF TO A LANDSCAPED AREA. DOWNSPOUTS MAY BE CONNECTED TO A
POP-UP DRAINAGE EMITTER IN THE LANDSCAPED AREA OR MAY DRAIN TO
SPLASH BLOCKS OR COBBLESTONES THAT DIRECT WATER AWAY FROM THE BUILDING.
10. CONTRACTOR TO FIELD VERIFY EXISTING DRAINAGE. IF THE EXISTING
DRAINAGE SYSTEM IS DAMAGED DURING EXCAVATION, CONTRACTOR SHALL
REPAIR AND/OR REROUTE DRAINAGE SYSTEM AND CONNECT TO EXISTING DRAINAGE FACILITY AS NECESSARY.
11. EXISTING PUBLIC IMPROVEMENTS THAT ARE DAMAGED BY THE PROJECT CONSTRUCTION SHALL BE REPAIRED OR REPLACED. EXISTING DAMAGED
PUBLIC IMPROVEMENTS WITHIN THE PROJECT LIMITS SHALL BE REPAIRED
OR REPLACED EVEN IF THE DAMAGE OCCURRED PRIOR TO THE START OF CONSTRUCTION.
12. EROSION AND SEDIMENT CONTROL FACILITIES SHALL BE INSTALLED PRIOR TO OCTOBER 1 AND SHALL BE MAINTAINED DAILY UNTIL APRIL 30. THESE
FACILITIES SHALL CONTROL AND CONTAIN EROSION-CAUSED SILT DEPOSITS
AND PROVIDE FOR THE SAFE DISCHARGE OF SILT-FREE STORM WATERS INTO EXISTING STORM DRAIN FACILITIES. EROSION AND SEDIMENT CONTROL
SUPPLIES MUST BE KEPT ON-SITE DURING THE DRY SEASON AND EMPLOYED, AS NECESSARY PRIOR TO AND DURING RAIN EVENTS.
13. SEASONALLY APPROPRIATE BEST MANAGEMENT PRACTICES FOR THE FOLLOWING SITE MANAGEMENT CATEGORIES MUST BE IMPLEMENTED YEARROUND: 1) EROSION CONTROL; 2) RUN-ON AND RUN-OFF CONTROL; 3) SEDIMENT CONTROL; 4) GOOD SITE MANAGEMENT; AND 5) NONSTORMWATER MANAGEMENT.
14. AN ENCROACHMENT PERMIT WILL BE REQUIRED FOR ANY CONSTRUCTION
ACTIVITY WITHIN A PUBLIC STREET RIGHT OF WAY THAT HAS BEEN ACCEPTED BY THE CITY.
SITE PLAN GENERAL NOTES
LOCATION OF ELECTRICAL PANEL
SEE COVER SHEET FOR PANEL OPTION AND MAXIMUM AMPERAGE FOR THE PROPOSED ADU. SEE TITLE SHEET UNDER OPTION SELECTIONS FOR REQ. ADDITIONAL CALCULATIONS BASED ON CHOSEN ELECTRICAL PANEL.
LOCATION OF FIRE HYDRANTS
INDICATE THE LOCATION OF ALL FIRE HYDRANTS WITHIN 500 FEET OF THE PROPERTY.
DRIVEWAY / PAVED ACCESS
SHOW THE PROPOSED (OR EXISTING) DRIVEWAY / PAVED ACCESS TO THE PROPOSED ADU.
TOPOGRAPHY - SHOW 1 FT CONTOURS ON SITE AND 20 FT OFFSITE. (REQUIREMENT MAY BE WAIVED AT BUILDING OFFICIALS DISCRETION.)
SHOW ALL EV CHARGING AND ALL ASSOCIATED CIRCUITS FOR NEW AND EXISTING LOCATIONS.
NOTE: THIS IS AN EXAMPLE SITE PLAN FOR AN INTERIOR
LOT. EXACT LAYOUT, DIMENSIONS, AND BEARINGS SHALL
BE PROVIDED BY OWNER/APPLICANT.
(E) EXISTING (N) NEW
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:48:56 PM
EXAMPLE SITE PLAN
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
AS-101
04/14/2026
RECORD SET
1-HR FIRE CONSTRUCTION
IS (N) ADU LESS THAN 5' - 0" TO ANY PROPERTY LINE AND/OR IS (N) ADU 10' - 0" OR LESS FROM ANY ADJACENT BUILDING OR STRUCTURE:
YES, IF YES, FIRE-RATED WALL REQUIRED PER 2025 CRC R302.1 AT LOCATIONS WHERE THE ADU IS LESS THAN 5' FROM THE PROPERTY LINE OR 10' FROM ANY ADJACENT BUILDING OR STRUCTURE.
FIRE RATED WALL DETAIL: 54/A-902
FIREBLOCKING IS REQUIRED IN PROJECTIONS, RAKES AND EAVES. SEE DETAILS: 41/A-905, 42/A-905, 41/A-907, 42/A-907, 41/A-909, 42/A-909, 44/A-906, 32/A-908, &44/A-910
THE FIRE-RESISTANCE RATING SHALL BE PERMITTED TO BE REDUCED TO 0 HOURS ON THE UNDERSIDE OF THE EAVE OVERHANG, IF
FIREBLOCKING IS PROVIDED FROM THE WALL TOP PLATE TO THE
UNDERSIDE OF THE ROOF SHEATHING IF ONE OF THE FOLLOWING SEPARATION DISTANCES ARE MET IN APPROPRIATE TABLE: TABLE 302.1(1) & TABLE 302.1(2).
A) NON-SPRINKLERED & FIRE SEPARATION DISTANCE PROJECTIONS ARE ≥ 2'-0" - < 5'-0"
B) SPRINKLERED & FIRE SEPARATION DISTANCE
PROJECTIONS ARE ≥ 2'
NO
DOES ANY ELEVATION ON SELECTED (N) ADU HAVE ≥ 25%
OPENINGS?
YES, THEN ARE ANY OF THOSE ELEVATIONS LESS THAN 5' FROM ANY PROPERTY LINE OR 10' OR LESS FROM ANY ADJACENT BUILDING OR STRUCTURE?
IF YES, THEN FIRE-RATED CONSTRUCTION IS REQUIRED PER 2025 CRC R302.1.
NO, NO ACTION NEEDED
PUBLIC SET
FOR USE IN THE CITY OF SAN RAMON
DW
A A
3 3
C C
1 1
28' - 0"
40' - 0"
28' - 0"
KITCHEN
6 A3-202
6 A3-202
5 A3-202
5 A3-202
2 2
B B
BATH
LIVING
W.I.C.
WH
BEDROOM
6 5
8 1 2
4 4
3 6
3 5
1 2
A3-202
3 A3-202
4 A3-202
1 A3-202
HALL
10' - 7" 5' - 5" 3' - 8" 5' - 5" 2' - 11"
3' - 5 1/2" 8' - 6 1/2" 28' - 0"
EQ EQ
4' - 3" 6' - 9" 9' - 0" 3' - 9" 4' - 3"
12' - 0" 28' - 0"
COVERED PORCH
STORAGE
B01 A04 A01
A05
B05 B04
B06
14' - 0" 14' - 0"
7-3/4" MAX.
C13 A03
TYP.
M02
C08
C10
X07 G02
C01
C12
EQ EQ
7 2' - 0"
40' - 0"
1' - 10"
B38
2' - 4"
7' - 10 1/2"
3' - 7" 3' - 0"
SEE AGING-IN-PLACE 5' - 0"
DETAILS: 51/ AD-904
A06
EQ 2' - 4" EQ
EXTERIOR - 5 1/2" WOOD STUD W/ PLYWOOD SHEATHING AND
STUCCO, ONE LAYER GYPSUM WALL BOARD INTERIOR.
INTERIOR - 5 1/2" WOOD STUD W/ONE LAYER GYPSUM WALL BOARD EACH SIDE.
INTERIOR - 3 1/2" WOOD STUD W/ONE LAYER GYPSUM WALL BOARD EACH SIDE.
REFER TO DETAIL ( ) FOR ADDITIONAL INFORMATION 54/ AD-902 A2.
SOLID CORE WOOD
EXTERIOR
B.
DOUBLE SLIDING
INTERIOR
C.
SLIDING GLASS
EXTERIOR.
D.
HOLLOW CORE
WOOD INTERIOR
T T
A1.
SOLID CORE WOOD
EXTERIOR ENTRY
T
T T
RANCH CRAFTSMAN MEDITERRANEAN
A.
SINGLE HUNG.
B.
SLIDER.
EQ EQ
PER SCHED.
PER SCHED. PER SCHED.
PER SCHED.
A
2 B
COVERED PORCH
X07
G02
20' - 0"
10" 6' - 8" 12' - 6"
10"
2' - 4" 11' - 8"
14' - 0"
7 1
1 A
2 B
COVERED PORCH
X07
G02
8' - 3" 11' - 9"
2' - 0" 5' - 0" 9' - 0"
20' - 0"
16' - 0"
7 1
1 A
2 B
1' - 0" 9' - 0" 5' - 0"
8' - 3" 11' - 9"
COVERED PORCH
12" 5' - 10" 1' - 5"
7' - 10" 1' - 6"
5 1/2"
8"
8" 9' - 10" 1' - 3"
X07
G02
4' - 0" 12"
20' - 0"
15' - 0"
7 1
1 A
2 7-3/4"
MAX.
X7
BEDROOM
5' - 6"
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:48:57 PM
FLOOR PLANS
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
A3-101
04/14/2026
RECORD SET
A1-201 A3-101 SCALE: 1/4" = 1'-0"
1 GROUND FLOOR PLAN
NO. TYPE
DOOR
WIDTH HEIGHT REMARKS
1 A1 3' - 0" 6' - 8" 1, 2
3 A3 2' - 8" 6' - 8" 1
4 A2 2' - 8" 6' - 8" 1
5 D 3' - 0" 6' - 8"
6 D 3' - 0" 6' - 8"
8 E 2' - 8" 6' - 8"
NO. TYPE
SIZE HEAD
WIDTH HEIGHT HEIGHT REMARKS
1 B 4' - 0" 4' - 0" 6' - 8"
2 B 4' - 0" 4' - 0" 6' - 8"
3 B 4' - 0" 4' - 0" 6' - 8"
4 B 3' - 0" 3' - 0" 6' - 8" 2
5 B 3' - 0" 2' - 0" 6' - 8" 2, 4
6 B 4' - 0" 4' - 0" 6' - 8"
1. REFER TO GENERAL NOTES SHEET G-101 AND G-102 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO STRUCTURAL PLANS FOR FURTHER INFORMATION.
3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION.
4. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
5. REFER TO PLUMBING PLANS FOR FURTHER INFORMATION.
6. ALL FURNITURE AND EQUIPMENT IS BY OWNER AND IS SHOWN FOR COORDINATION PURPOSES ONLY.
7. DIMENSIONS ARE TO FACE OF SHEATHING UNLESS SPECIFICALLY NOTED OTHERWISE.
8. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL
MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS, SHELVING AND BATHROOM FIXTURES.
9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS.
10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO ROUGH DOOR OPENING.
11. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL
ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE MAINTAINED.
12. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS,
PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY OF PARTITION RATING.
13. PER 2025 CRC R318.3 FLOORS OR LANDINGS AT EXTERIOR DOORS SHALL BE
AT LEAST AS WIDE AS DOOR SERVED AND SHALL PROVIDE A LENGTH IN THE DIRECTION OF TRAVEL EQUAL TO 36 INCHES MINIMUM. SLOPE OF EXTERIOR LANDINGS SHALL NOT EXCEED 1/4" PER FOOT (2% SLOPE).
14. PER 2025 CRC 328.1.1 REINFORCEMENT FOR GRAB BARS SHALL BE PROVIDED IN AT LEAST ONE BATHROOM. 1. REINFORCEMENT SHALL BE
SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2X8 INCH NOMINAL LUMBER OR OTHER MATERIAL PROVIDING EQ. HT. AND CAPACITY. REINFORCEMENT ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. 3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED
ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. 4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. 5. BATHTUB AND COMBINATION BATHTUB/SHOWER
REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A
LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. REFER TO SHEET A-903 FOR MORE INFORMATION.
FLOOR PLAN GENERAL NOTES
LEGEND
WINDOW SCHEDULE
DOOR SCHEDULE
KEYNOTES
1. REQUIRED EGRESS WINDOW. REFER TO WINDOW GENERAL NOTE #4 FOR ADDITIONAL INFORMATION.
2. WINDOW INCLUDES BOTH PANES TEMPERED GLAZING.
3. OPTIONAL WINDOW. SEE TITLE SHEET FOR SELECTIONS FOR MORE INFO. AT
LEAST ONE EGRESS OPENING REQUIRED AT ALL BEDROOMS, SEE GENERAL WINDOW NOTE #5 FOR EGRESS REQUIREMENTS.
4. REQUIRED TO PROVIDE OBSCURE / PRIVACY GLASS.
5. @ CASEMENT WINDOWS, INCLUDE BOTH PANES TEMPERED GLAZING.
6. MULLED WINDOW ASSEMBLY
WINDOW REMARKS
1. REFER TO PLANS FOR LOCATION OF DOORS.
2. CONTRACTOR TO VERIFY ROUGH OPENING SIZE WITH DOOR
MANUFACTURER SPECIFICATIONS PRIOR TO CONSTRUCTION.
3. CONTRACTOR TO VERIFY ACTUAL DOOR SIZE TO FIT FINISH OPENING PRIOR TO FABRICATION OF DOOR AND FINISH OPENING.
4. FIRE RATED DOORS SHALL BE SOLID WOOD OR SOLID HONEYCOMB CORE STEEL DOOR 1-3/8" THICK OR COMPLIANT WITH CRC 2025 SECTION R302.5.1.
DOORS SHALL BE SELF-CLOSING AND SELF-LATCHING WITH WEATHER STRIPPING TO BE TIGHT FITTING.
5. EXTERIOR DOORS SHALL EITHER HAVE A FIRE-RESISTANCE RATING OR MUST COMPLY WITH THE FOLLOWING REQUIREMENTS:
A. STILES AND RAILS SHALL NOT BE LESS THAN 1-3/8" THICK.
B. PANELS SHALL NOT BE LESS THAN 1-1/4" THICK, EXCEPT FOR THE
EXTERIOR PERIMETER OF THE PANEL SHALL BE PERMITTED TO TAPER TO A TONGUE OF NOT LESS THAN 3/8" THICK.
6. GLAZING IN DOORS SHALL BE TEMPERED PER CRC 2025 SECTION R324.4.1.
PANES INDICATED IN DOOR LEGEND WITH (T).
7. IF STRUCTURE, IS IN A WUI ZONE OR FHSZ, DOOR MUST COMPLY WITH CWUIC 2025 SEC. 504.9
DOOR GENERAL NOTES
DOOR LEGEND
WINDOW LEGEND
A01 30" WIDE FREE STANDING ELECTRIC RANGE OVEN. VENT TO EXTERIOR, STAINLESS STEEL.
A03 30" WIDE BUILT-IN MICROWAVE WITH RANGE VENT, STAINLESS STEEL.
A04 24" WIDE FRONT CONTROL UNDERCOUNTER DISHWASHER.
A05 REFRIGERATOR LOCATION. PROVIDE 36" SPACE WITH ROUGH PLUMBING FOR ICE MAKER (RECESS IN WALL) OR PER OWNER'S SPECIFICATIONS.
A06 STACKED WASHER/DRYER MACHINE LOCATION. PROVIDE WASTE AND WATER IN RECESSED WALL BOX. PROVIDE DRYER VENT. VENT TO OUTSIDE AIR.
B01 30" SINGLE COMPARTMENT UNDER-MOUNT KITCHEN SINK W/ GARBAGE DISPOSAL. REFER TO WATER EFFICIENCY REQUIREMENTS ON CALGREEN CODE NOTES SHEET.
B04 LAVATORY SINK. REFER TO WATER EFFICIENCY REQUIREMENTS ON CALGREEN CODE NOTES SHEETS.
B05 WATER CLOSET. REFER TO WATER EFFICIENCY REQUIREMENTS ON CALGREEN CODE NOTES SHEETS.
B06 32" x 60" x 72" TUB AND SHOWER COMBINATION. MODEL BY BUILDER.
PROVIDE SHOWER ROD.
B38 MULTI-ZONE HEAT PUMP CONDENSING UNIT. REFER TO PLANS FOR LOCATION OF INDOOR FAN FAN COIL UNITS. REFER TO TITLE 24 FOR ADDITIONAL INFORMATION. PROVIDE CONCRETE PAD MIN. 6" LARGER THAN UNIT IN EACH DIRECTION, 3" MIN. ABOVE GRADE.
C01 SINGLE WOOD SHELF AND POLE.
C08 12" DEEP UPPER CABINET
C10 24" DEEP UPPER CABINET.
C12 34 1/2" HIGH BASE CABINET AND COUNTERTOP.
C13 30" HIGH BASE CABINET AND COUNTERTOP.
G02 CONCRETE FLATWORK. 1/4"/FT SLOPE AWAY FROM BUILDING.
M02 DOWNSPOUT. CONNECT TO STORM DRAIN SYSTEM
X07 PORCH LAYOUT VARIES BY SELECTED STYLE. REFER TO STYLE SPECIFIC PORCH PLANS.
A1-201 A3-101 SCALE: 1/4" = 1'-0"
2 PORCH-SUBURBAN RANCH
A1-201 A3-101 SCALE: 1/4" = 1'-0"
3 PORCH-CRAFTSMAN
A1-201 A3-101 SCALE: 1/4" = 1'-0"
4 PORCH-MEDITERRANEAN
A1-201 A3-101 SCALE: 1/4" = 1'-0"
OPTIONAL SLIDING
5 DOOR @ BEDROOM
NO. TYPE
SIZE HEAD
WIDTH HEIGHT HEIGHT REMARKS
7 A 6' - 0" 5' - 0" 8' - 8" 1, 3
OPTIONAL WINDOWS
NO. TYPE
DOOR
WIDTH HEIGHT REMARKS
X7 C 5' - 0" 6' - 8" 1, 2, 4
OPTIONAL DOORS
1. EXTERIOR DOOR.
2. GLAZING PER DOOR TYPES. REFER TO GENERAL DOOR NOTE #6
3. REQUIRED OPENING OF NOT LESS THAN 100 IN2 FOR MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR BY APPROVED MEANS. [CMC SEC. R504.4.1]
4. VENT DOOR AS REQUIRED PER WATER HEATER MANUFACTURER
REQUIREMENTS / SPECIFICATIONS
5. OPTIONAL DOOR.
DOOR REMARKS
1. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS.
2. CONTRACTOR TO VERIFY EXACT ROUGH OPENING SIZES PRIOR TO FABRICATION OF ROUGH OPENINGS.
3. ALL GLAZING IS DOUBLE PANE UNLESS OTHERWISE NOTED.
4. EGRESS WINDOWS SHALL HAVE A CLEAR OPENING WITH THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44" AFF, MIN. NET CLEAR OPENING FOR EMERGENCY ESCAPE SHALL BE 5.7 S.F. EXCEPT: 5 S.F. MIN. AT GROUND FLOOR. MINIMUM NET CLEAR OPENING DIMENSIONS: HEIGHT: 24", WIDTH: 20". [CRC SEC. R310.2] EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY PER CRC 2025, SECTION 310.1.
5. GLAZING IN WALLS ADJACENT TO BATHTUB / SHOWER WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE SHALL BE SAFETY GLAZING. [CRC SEC. R324.4.5]
6. REFER TO WINDOW SCHEDULE AND WINDOW LEGEND FOR MORE
INFORMATION.
7. IF STRUCTURE IS IN A WUI ZONE OR FHSZ, WINDOW MUST COMPLY WITH CWUIC SECTION 504.8
WINDOW GENERAL NOTES
8. REFER TO ENERGY COMPLIANCE REPORTS TO VERIFY U-FACTOR, SHGC AND ADDITIONAL WINDOW REQUIREMENTS. ALL OPENINGS TO BE
U-FACTOR = (.3) , SHGC = (.23). BUG SCREEN REQUIRED (PER TITLE 24).
PUBLIC SET
FOR USE IN THE CITY OF SAN RAMON
DW
LUXURY VINYL PLANK
(LVT)
FINISH LEGEND
CARPET
(CPT)
CERAMIC TILE
(CT)
CONCRETE
(EC)
KITCHEN LIVING
BATH
HALL
WH
W.I.C.
BEDROOM
COVERED PORCH
STORAGE
A1-201 A3-111 SCALE: 1/4" = 1'-0" 1 GROUND FLOOR FINISH PLAN DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:48:58 PM
FINISH PLANS
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
A3-111
04/14/2026
RECORD SET
FINISH SCHEDULE
1. REFER TO GENERAL NOTES SHEET G-101 AND G-102 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
3. REFER TO PLUMBING PLANS FOR FURTHER INFORMATION.
4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES AND INTERIOR FINISH DETAILS.
5. ALL HARD SURFACE FLOORING SHALL BE SLIP RESISTANT AND MEET THE ANSI A326.3 STANDARD FOR MEASURING THE DYNAMIC COEFFICIENT OF FRICTION (DCOF).
6. ALL FLOORING MATERIALS SHALL COMPLY WITH 2025 CBC SEC. 804.1.
7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2025 CBC TABLE 803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
FINISH PLAN GENERAL NOTES
NAME FLOOR WALL CEILING NOTES
KITCHEN LVT GWB GWB WR GWB BEHIND COUNTER
LIVING LVT GWB GWB
BATH CT WR GWB WR GWB IF CERAMIC TILE IS PROVIDED IN
TUB/SHOWER AREAS, PROVIDE
BACKER BOARDS PER CRC R702.4.2
W.I.C. CPT GWB GWB
WH EC GWB GWB
BEDROOM CPT GWB GWB
HALL LVT GWB GWB
STORAGE EC GWB GWB
PUBLIC SET
FOR USE IN THE CITY OF SAN RAMON
LEGEND
3-COAT CEMENT PLASTER
CEMENTITOUS LAP SIDING
CEMENTITOUS BOARD AND BATTEN SIDING
CEMENTITOUS SHINGLE SIDING
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
C B A
T02
S04
KITCHEN
ATTIC
COVERED
PORCH
2' - 6"
ALLOW AIRFLOW
ATTIC ACCESS REQ.
PER CRC R807
OPTIONAL WINDOW
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
1 2 3
LIVING HALL WHW/D
T02
S04 KITCHEN
ATTIC
G14
S03
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
C B A 1' - 0" 6' - 3" (SPRING POINT)
1' - 0" 6' - 3" (SPRING POINT)
K10
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
3 2 1
K10 K13 L15 H08 K01
M01
M02
B14 B38
B18
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
A B C
K01 L15 K11
AD-905
21 01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
1 2 3
K01 H08 K10 K11 L09 L15 K13
M02
M01
21 AD-905
34 AD-905
14 AD-905
AD-905
11 6' - 3" (SPRING POINT)
1' - 0"
6' - 3" (SPRING POINT) 1' - 0"
AD-905
53 ± 11' - 5"
AD-905
51 DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:49:01 PM
EXTERIOR ELEVATIONS &
BUILDING
SECTIONS-MEDITERRANEAN
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
A3-201
04/14/2026
RECORD SET
A3-121 A3-201 SCALE: 1/4" = 1'-0"
6 PLAN 3 - MEDITERRANEAN DESIGN - SECTION 2
A3-121 A3-201 SCALE: 1/4" = 1'-0"
5 PLAN 3 - MEDITERRANEAN DESIGN - SECTION 1
A3-201 SCALE: 1/4" = 1'-0"
2 PLAN 3 - MEDITERRANEAN DESIGN - RIGHT
A3-201 SCALE: 1/4" = 1'-0"
1 PLAN 3 - MEDITERRANEAN DESIGN - REAR
A3-201 SCALE: 1/4" = 1'-0"
4 PLAN 3 - MEDITERRANEAN DESIGN - LEFT
A3-201 SCALE: 1/4" = 1'-0"
3 PLAN 3 - MEDITERRANEAN DESIGN - FRONT
KEYNOTES
B14 50 GALLON TANK TYPE ELECTRIC WATER HEATER. REFER TO TITLE 24 FOR ADDITIONAL INFORMATION. PROVIDE CONCRETE PAD MIN. 6" LARGER THAN UNIT IN EACH DIRECTION. 3" MIN. ABOVE GRADE. ENCLOSURE REQUIRED WHEN OUTDOORS.
B18 ELECTRIC PANEL TBD.
B38 MULTI-ZONE HEAT PUMP CONDENSING UNIT. REFER TO PLANS FOR LOCATION OF INDOOR FAN FAN COIL UNITS. REFER TO TITLE 24 FOR ADDITIONAL INFORMATION. PROVIDE CONCRETE PAD MIN. 6" LARGER THAN UNIT IN EACH DIRECTION, 3" MIN. ABOVE GRADE.
G14 4" CONCRETE SLAB ON GRADE, REFER TO STUCTURAL PLANS H08 ATTIC VENT. PAINT FINISH TO MATCH ROOF COLOR. REFER TO COLORS AND MATERIALS.
K01 CONCRETE S-TILE.
K10 3-COAT CEMENT PLASTER SYSTEM O/ LATH O/ WATER RESISTIVE BARRIER PER 2025 CRC 703.7.3. EXTERIOR BUILDING FINISH SHALL BE IN COMPLIANCE WITH 2025 CWUIC 504.
K11 DOOR PER PLAN
K13 WINDOW PER PLAN
L09 DECORATIVE GABLE VENT, ROUND 3-HOLE
L15 WIN/DOOR SURROUNDS
M01 GUTTER. CONNECT TO DOWNSPOUT. PROVIDE MEANS TO PREVENT ACCUMULATION OF LEAVES AND DEBRIS IN GUTTER PER CRC R327.5.4 M02 DOWNSPOUT. CONNECT TO STORM DRAIN SYSTEM
S03 ROOF INSULATION. REFER TO TITLE 24 (R-38 MIN.).
S04 2X6 WALL INSULATION. REFER TO TITLE 24 (R-21 MIN.)
T02 2X6 WOOD STUD WALL. REFER TO STRUCTURAL.
1. REFER TO GENERAL NOTES SHEET G-101 & G-102 FOR ADDITIONAL
REQUIREMENTS
2. SEE DETAILS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
3. REFER TO ROOF PLAN FOR OVERHANGS. FASCIA PER DETAILS. PROVIDE ALUMINUM GUTTER. SEE ROOF PLAN FOR APPROXIMATE DOWNSPOUT LOCATIONS, U.N.O.
4. REFER TO DOOR AND WINDOW SCHEDULES AND TYPES FOR DOOR AND WINDOW INFORMATION.
5. THE NOMINAL THICKNESS AND ATTACHMENT OF EXTERIOR WALL COVERINGS SHALL BE IN ACCORDANCE WITH 2025 CRC TABLE R703.3(1).
6. GYPSUM SHEATHING SHALL BE ATTACHED TO EXTERIOR WALLS IN ACCORDANCE WITH 2025 CRC TABLE R602.3 (1).
7. CLADDING ATTACHMENT OVER FOAM SHEATHING TO WOOD FRAMING IN ACCORDANCE WITH 2025 CRC R703.15. REFER TO 2025 CRC R703.8 FOR
ANCHORED MASONRY OR STONE VENEER INSTALLED OVER FOAM
SHEATHING.
ELEVATION GENERAL NOTES
1. THE PURPOSE OF THESE DRAWINGS IS TO SHOW CONSTRUCTION MATERIALS/ASSEMBLIES. FOR SPECIFIC SIZES AND DETAILS REFER TO ARCHITECTURAL PLANS, ELEVATIONS, DETAILS, AND STRUCTURAL PLANS. *KEYNOTES ONLY APPLY IF REFERENCED ON PLANS.
2. WALL ASSEMBLIES TO BE PER FLOOR PLAN.
3. DOORS AND WINDOWS TO BE PER APPLICABLE SCHEDULE. REFER TO FLOOR PLANS FOR IDENTIFICATION.
4. INSULATION: REFER TO TITLE 24 REPORT AND "INSULATION" NOTES ON SHEET FOR ADDITIONAL RATINGS, REQUIREMENTS, AND INFORMATION.
5. FIREBLOCKING TO BE LOCATED PER 2025 CRC SECTION R302.11:
A. SECTION R302.11 -
1. FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF
STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND
PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS:
1. VERTICALLY AT CEILING AND FLOOR LEVELS
2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET.
2. AT INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND
HORIZONTAL SPACES SUCH AS SOFFITS, DROP CEILINGS AND COVE CEILINGS.
3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS
SHALL COMPLY WITH 2025 CRC SECTION R302.7.
4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT
CEILINGS AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO
RESIST THE FREE PASSAGE OF FLAME PRODUCTS OF COMBUSTION.
THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE
REQUIRED TO MEET THE ASTM E136 REQUIREMENTS.
5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE 2025 CRC SECTION R1003.19.
6. FIREBLOCKING OF CORNICES OF A TWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING-UNIT SEPARATION.
B. SECTION R302.11.1 - FIREBLOCKING MATERIALS SHALL CONSIST OF FOLLOWING MATERIALS:
1. TWO-INCH NOMINAL LUMBER
2. TWO THICKNESSES OF ONE-INCH NOMINAL LUMBER WITH BROKEN
LAP JOINTS
3. THE THICKNESS OF 0.719-INCH WOOD STRUCTURAL PANELS WITH JOINTS BACKED BY 0.719-INCH WOOD STRUCTURAL PANELS
4. THE THICKNESS OF 0.75-INCH PARTICLE BOARD WITH JOINTS BACKED BY 0.75-INCH PARTICLE BOARD
5. ONE-HALF-INCH GYPSUM BOARD
6. ONE-FOURTH-INCH CEMENT-BASED MILLBOARD
7. BATTS OR BLANKETS OF MINERAL WOOL, MINERAL FIBER OR OTHER
APPROVED MATERIAL INSTALLED IN SUCH A MANNER AS TO BE
SECURELY RETAINED IN PLACE
8. CELLULOSE INSULATION INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263, FOR THE SPECIFIC APPLICATION.
6. PER 2025 CRC SECTION R304.1 SLEEPERS AND SILLS ON A CONCRETE OR
MASONRY SLAB THAT IS IN DIRECT CONTACT WITH GROUND, UNLESS
SEPARATED BY AN IMPERVIOUS MOISTURE BARRIER SHALL BE NATURALLY
DURABLE OR PRESERVATIVE-TREATED WOOD IN ACCORDANCE WITH AWPA U1.
7. REFER TO RCP'S FOR SOFFIT DIMENSIONS AND FURTHER INFORMATION.
8. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG EQUIPMENT AND FIXTURES OCCUR.
9. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2025 CRC 302.9 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
SECTIONS GENERAL NOTES
PUBLIC SET
FOR USE IN THE CITY OF SAN RAMON
(ALL STYLES)
*OWNER/APPLICANT REQ. TO SELECT ONE OPTION FOR ALL OF THE FOLLOWING AND MARK THROUGH NON-APPLICABLE OPTIONS AND DETAILS THROUGHOUT SET:
SUBURBAN RANCH
BOARD & BATTEN SIDING
(A) FIBER CEMENT BOARD & BATTEN (CRC R703.10.2)
(B) VERTICAL WOOD PANEL BOARD & BATTEN (CRC R703.5.1)
WATER HEATER
(B) ALTERNATIVE WATER HEATER WITH STIPULATION THAT NEW T24 ENERGY REPORT IS PROVIDED. MFR. & MODEL:______________________________________ (A) NORTHWEST ENERGY EFFICIENCY ALLIANCE (NEEA) RATED HEAT PUMP WATER HEATER; SPECIFIC BRAND/MODEL MUST BE INSTALLED (PER TITLE 24). *OWNER OR APPLICANT TO SELECT (1) OF THE (3) FOLLOWING STYLES (BELOW) AND ONE OF EACH OF THE SUBSEQUENT OPTIONS THEREIN. FOR CLARITY, CROSS OUT OTHER STYLES AND STYLE OPTIONS THROUGHOUT THE ENTIRE DRAWING SET.
ELECTRICAL PANEL (SEE PLANS & SITE PLAN FOR LOCATION)
(B) A NEW ELEC. SUBPANEL CONNECTS TO THE ELEC. MAIN PANEL OF 220 AMP ON THE PRIMARY HOME WITH A 225 AMP MIN. BUSBAR RATING
(A) NEW ELEC. MAIN PANEL OF 200 AMP MIN. WITH 225 AMP MIN. BUSBAR RATING (C) NEW ELEC. MAIN PANEL MIN. 400 AMP DUAL METER AT PRIMARY HOUSE WITH A NEW ELEC. SUB-PANEL AT ADU THAT CONNECTS TO THE MAIN PANEL OPTIONAL SLIDING DOOR @ KITCHEN/LIVING
(B) NO; WINDOW 7 TO REMAIN
(A) YES; REPLACE W/ DOOR X7
(A) EXT. TOUNGE & GROOVE
(B) FIBER CEMENT
(C) EXT. GRADE PLYWOOD
EXTERIOR EAVES, RAKES, & SOFFITS MATERIAL SELECTION
STYLE-BASED OPTIONS
OPTION SELECTION
EXTERIOR TRIM ELEMENTS
(A) FIBER CEMENT
(B) EXT. GRADE WOOD
BASE TRIM
(A) YES
(B) NO
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:51:48 PM
TITLE SHEET - PLAN 3 - SUBURBAN
RANCH
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
G-009
04/14/2026
PUBLIC SET
GENERAL
G-009 TITLE SHEET - PLAN 3 - SUBURBAN RANCH
G-101 GENERAL NOTES
G-102 GENERAL NOTES, ABBREVIATIONS, & SYMBOLS
G-201 CAL GREEN RESIDENTIAL MANDATORY MEASURES
G-202 CAL GREEN RESIDENTIAL MANDATORY MEASURES
ENERGY COMPLIANCE
T24-000 ENERGY MANDATORY REQUIREMENTS
T24-005 ENERGY COMPLIANCE REPORT - PLAN 3
T24-006 ENERGY COMPLIANCE REPORT - PLAN 3
ARCHITECTURAL SITE
AS-101 EXAMPLE SITE PLAN
AS-102 ARCHITECTURAL SITE PLAN
ARCHITECTURAL
A3-101 FLOOR PLANS
A3-112 ELECTRICAL & MECHANICAL PLANS
A3-123 ROOF PLANS & REFLECTED CEILING PLANS-SUBURBAN RANCH A3-203 EXTERIOR ELEVATIONS & BUILDING SECTIONS-SUBURBAN RANCH A3-111 FINISH PLANS
ARCHITECTURAL DETAILS
AD-901 ARCHITECTURAL DETAILS - COMMON - FLASHING
AD-902 ARCHITECTURAL DETAILS - COMMON
AD-903 ARCHITECTURAL DETAILS - COMMON - ROOF
AD-904 ARCHITECTURAL DETAILS - AGING-IN-PLACE
AD-909 ARCHITECTURAL DETAILS - SUBURBAN RANCH
AD-910 ARCHITECTURAL DETAILS - SUBURBAN RANCH
AD-913W ARCHITECTURAL DETAILS - ASPHALT SHINGLE ROOF - WUI
STRUCTURAL
S-101 SHEET INDEX, ABBREVIATIONS, & SYMBOLS
S-102 GENERAL NOTES
S-103 GENERAL NOTES, SPECIAL INSPECTION & TESTS
S-201 PIER FOUNDATION & ROOF FRAMING PLANS - STICK
S-202 PIER FOUNDATION & ROOF FRAMING PLANS - TRUSS
S-301 TYPICAL CONCRETE DETAILS
S-302 TYPICAL CONCRETE DETAILS
S-311 CONCRETE DETAILS
S-401 TYPICAL WOOD DETAILS
S-402 TYPICAL WOOD DETAILS
S-403 TYPICAL WOOD DETAILS
S-404 TYPICAL WOOD DETAILS
S-421 ROOF FRAMING DETAILS
S-422 ROOF FRAMING DETAILS
S-431 ROOF FRAMING DETAILS
Grand total: 37
SAN RAMON PROTOTYPE ACCESSORY DWELLING UNIT - PLAN 3 - SUBURBAN RANCH SQUARE FOOTAGE CONDITIONED?
ADU-PLAN 3 720 SF CONDITIONED
COVERED PORCH-PLAN 3 183 SF UNCONDITIONED
STORAGE-PLAN 3 8 SF UNCONDITIONED
PROJECT DIRECTORY PROJECT INFORMATION
UTILITIES
SHEET INDEX
ADDRESS:
CONTACT:
EMAIL:
PHONE:
RRM DESIGN GROUP
3765 S HIGUERA ST, SUITE 102
SAN LUIS OBISPO, CA 93401
P:(805) 543-1794
ARCHITECT
RANDY RUSSOM
[email protected]
USER LICENSE AGREEMENT
SIGNATURE DATE
VICINITY MAP (TO BE PROVIDED BY OWNER OR APPLICANT)
WATER AND SEWER SERVICE _________________________________________
ELECTRICAL SERVICE
GAS SERVICE
SEWER SERVICE
GARBAGE SERVICE
CABLE SERVICE
_________________________________________
_________________________________________
_________________________________________
_________________________________________
_________________________________________
(TO BE PROVIDED BY APPLICANT OR OWNER)
*FOR BUILDING DEPARTMENT REVIEW, INITIAL WHEN SECTION HAS BEEN REVIEWED
1. ANY PROPOSED ENERGY STORAGE SYSTEM (ESS) SHALL FOLLOW SINGLE-FAMILY RESIDENTIAL MANDATORY REQ. SUMMARY SECTION 150.0(s) AND WILL REQUIRE A SEPARATE PERMIT TO BE PULLED BY APPLICANT.
2. VARIABLE CAPACITY HEAT PUMP COMPLIANCE OPTION (VERIFICATION DETAILS FROM VCHP STAFF REPORT, APPENDIX B, AND RA3) (PER TITLE 24).
3. THIS PLAN IS INTENDED FOR FLAT LOTS (SLOPING LESS THAN 10" ACROSS THE
LONGEST BUILDING DIMENSION), WITHOUT HIGHLY EXPANSIVE OR LIQUEFIABLE
SOILS, WHERE THE MAIN DWELLING UNIT IS SUPPORTED IN SHALLOW FOOTINGS WITH SLABS ON GRADE CONSTRUCTION. IF THE PROJECT SITE DEVIATES FROM ANY
OF THE AFOREMENTIONED QUALITIES, AS DETERMINED BY THE BUILDING OFFICIAL,
THERE PRE-APPROVED ADU FOUNDATION PLANS AND DETAILS ARE NOT APPLICABLE.
ADDITIONAL INFORMATION:
IS THE ADU 5' - 0" OR LESS TO ANY PROPERTY LINE AND/OR IS THE ADU 10' - 0" OR LESS FROM ANY ADJACENT BUILDING OR STRUCTURE?
NO
SUPPORTING DOCUMENTS
PREPARED BY:
DATE PREPARED:
JOB NUMBER:
CARSTAIRS ENERGY
ENERGY COMPLIANCE
FEBRUARY 13, 2026
26-01086
PLEASE PROVIDE THE WASTE RECYCLE FORM FILLED OUT AND SIGNED PRIOR TO ISSUANCE. THE OWNER/APPLICANT/CONTRACTOR/PERSON DOING THE WORK IS REQUIRED TO RECYCLE 75% OF ALL PROJECT CONSTRUCTION AND DEMOLITION DEBRIS.
UTILITY, GRADING, AND DRAINAGE PLAN TO BE PROVIDED BY OTHERS.
HERS VCHP: HERS RATER WILL NEED TO FOLLOW THE VERIFICATION AND TESTING
PROTOCOL FOR THE VARIABLE CAPACITY HEAT PUMP CREDIT REQUIREMENTS,
INCLUDING BUT NOT LIMITED TO, VERIFIED REFRIGERANT CHARGE, VERIFIED MINIMUM HSPF AND EER/SEER, AND CAPACITY; DUCTLESS INDOOR UNITS AND THE COMPONENTS ARE WITHIN THE CONDITIONED ENVELOPE; AND AIRFLOW PROVIDED TO ALL HABITABLE SPACES (BEDROOMS AND LIVING SPACE).
THE FOLLOWING IS A SUMMARY OF THE FEATURES THAT MUST BE FIELD-VERIFIED BY
A CERTIFIED HERS RATER AS A CONDITION FOR MEETING THE MODELED ENERGY PERFORMANCE OF THIS COMPUTER ANALYSIS. REGISTERED CF2RS AND CF3RS ARE REQUIRED TO BE COMPLETED IN THE HERS REGISTRY.
• QUALITY INSULATION INSTALLATION (QII)
• INDOOR AIR QUALITY VENTILATION
• KITCHEN RANGE HOOD
• VERIFIED REFRIGERANT CHARGE
• AIRFLOW IN HABITABLE ROOMS (SC3.1.4.1.7)
• VERIFIED HEAT PUMP RATED HEATING CAPACITY
• WALL-MOUNTED THERMOSTAT IN ZONES GREATER THAN 150 FT2 (SC3.4.5) • DUCTLESS INDOOR UNITS LOCATED ENTIRELY IN CONDITIONED SPACE (SC3.1.4.1.8)
HERS QII REQUIRED
OWNER/APPLICANT HAS COMPLETED SPECIAL INSPECTION FORM
OWNER/APPLICANT SIGNATURE: _____________________________ SEE SHEET S-103 FOR REQUIRED SPECIAL INSPECTIONS
A REGISTERED DESIGN PROFESSIONAL SHALL COMPLETE THE CITY OF SAN RAMON STATEMENT OF REQUIRED SPECIAL INSPECTIONS CERTIFICATE (FORM PLG-240) PRIOR TO PERMIT ISSUANCE. IDENTIFY THE TYPE OF WORK REQUIRING SPECIAL
INSPECTIONS IN THE PLANS AND THE INDIVIDUALS OR FIRMS RESPONSIBLE FOR THE SPECIAL INSPECTION ELEMENT(S). FOR FURTHER INSTRUCTIONS SEE S-103.
SPECIAL INSPECTIONS REQ'D
OWNER/APPLICANT SIGNATURE:____________________________
OWNER/APPLICANT TO SIGN USER AGREEMENT BELOW:
BY USING THESE PERMIT READY ACCESSORY DWELLING UNIT CONSTRUCTION
DOCUMENTS, THE USER AGREES TO RELEASE, HOLD HARMLESS, AND INDEMNIFY
THE CITY OF SAN RAMON, ITS ELECTED OFFICIALS AND EMPLOYEES, RRM DESIGN
GROUP, AND THE ARCHITECT OR ENGINEER WHO PREPARED THESE
CONSTRUCTION DOCUMENTS FROM ANY AND ALL CLAIMS, LIABILITIES, SUITS AND
DEMANDS ON ACCOUNT OF ANY INJURY, DAMAGE OR LOSS TO PERSONS OR
PROPERTY, INCLUDING INJURY OR DEATH, OR ECONOMIC LOSSES, ARISING OUT OF THE USE OF THESE CONSTRUCTION DOCUMENTS.
THE PLANS ATTACHED HERE ARE APPROVED FOR ONLY USE IN CITY OF SAN RAMON. NO DEVIATIONS, ALTERATIONS, OR OPTIONS BEYOND THOSE
SPECIFICALLY INDICATED IN THE PLANS ARE ALLOWED WITHOUT PRIOR APPROVAL BY THE ISSUING JURISDICTION AND CHIEF BUILDING OFFICIAL. ANY
UNAPPROVED PLAN MODIFICATIONS MAY BE DEVELOPED THROUGH RRM DESIGN GROUP AND THE APPROVING JURISDICTION IF REQUIRED. THIS SET OF PLANS SHALL NOT BE USED FOR A PUBLIC HOUSING PROJECT.
YES; IF YES, FIRE RATED WALL, ROOF & PROJECTIONS REQUIRED PER 2025 CBC, CHAPTER 2. FIRE RATED WALL DETAIL: 54/A-902. FIRE RATED ROOF DETAIL: 22/A-903
IF YES, FIREBLOCKING IS REQUIRED IN PROJECTIONS, RAKES AND EAVES.
SEE DETAILS: 41/A-905, 42/A-905, 41/A-907, 42/A-907, 41/A-909, & 42/A-909 (TO BE PROVIDED BY
OWNER / APPLICANT)
APPLICANT:
ADDRESS:
CONTACT:
EMAIL:
PHONE:
OWNER:
ADDRESS:
CONTACT:
EMAIL:
PHONE:
SITE INFORMATION:
APN:
ZONING:
REAR: 4' - 0" (A.B. NO. 86)
FRONT:
SIDES: 4' - 0" (A.B. NO. 86)
SETBACKS
_____________
_____________
_____________
REQUIRED: PROPOSED:
SETBACK RESTRICTIONS - FIRE RATINGS:
WASTE WATER:
SEWER
*FOR BUILDING DEPARTMENT REVIEW, INITIAL WHEN SECTION HAS BEEN REVIEWED
STAFF INITIALS
BUILDING INFORMATION:
CONSTRUCTION TYPE: VB
MAX HEIGHT ALLOWED: 16' - 0"
ZONING:
SPRINKLERED: (SEE FIRE SPRINKLER
SECTION ON THIS SHEET)
MAX HEIGHT PROPOSED:
NUMBER OF STORIES: 1 OCCUPANCY GROUP: R-3
PROJECT ADDRESS: _________________________________________________________________________________
SEPARATE PERMITS DEFERRED SUBMITTAL
SOLAR PV SYSTEM TRUSS CALCULATIONS
PROJECT SCOPE:
1. 2.
CONSTRUCTION OF A NEW DETACHED 1 STORY 708 SF ACCESSORY DWELLING UNIT WITH 1 BEDROOMS AND 1 BATH.
ALL THE WORK SHOWN IN THE DRAWINGS AND SPECIFICATIONS.
YES, PV SYSTEM REQUIRED
NO, PV NOT REQUIRED (FOR ADUS 652 SF OR SMALLER) PER CALIFORNIA ENERGY CODE SECTION 150.1(C)14 EXCEPTION (IF NO, OWNER/APPLICANT REQ.
TO SELECT ONE):
1) FOR STEEP SLOPE ROOFS, WITH NORTHERLY AZIMUTH THAT LIES BETWEEN 300 DEGREES AND 90 DEGREES FROM TRUE NORTH. IF THE SARA IS LESS THAN 80 CONTIGUOUS SQUARE FEET.
2) PV SYSTEM SIZE SPECIFIED BY SECTION 150.1(C)14 IS LESS THAN 1.8 KWDC. 3) BUILDINGS W/ APPROVED ROOF DESIGNS, WHERE THE ENFORCEMENT
AUTHORITY DETERMINES IT IS NOT POSSIBLE FOR THE PV SYSTEM 4) FOR BUILDINGS THAT ARE APPROVED BY THE LOCAL PLANNING DEPARTMENT PRIOR TO JANUARY 1, 2020 WITH MANDATORY CONDITIONS FOR APPROVAL. 5) PV SYSTEM SIZES DETERMINED USING EQUATION 150.1-C MAY BE REDUCED BY 25 PERCENT IF INSTALLED IN CONJUNCTION WITH A QUALIFYING BATTERY STORAGE SYSTEM.
OTHER, (REQ. APPROVAL) SPECIFY:_________________________________________ SOLAR READY REQUIREMENTS SHALL BE IMPLEMENTED. FOR MORE INFORMATION SEE "SOLAR READY NOTES" ON SHEET G-102.
PHOTOVOLTAIC SYSTEM (PV)
*SEPARATE SUBIMTTAL
+/- 11'-5"
SIGNATURE DATE
1. DETAILED SPRINKLER PLANS SHALL BE SUBMITTED TO THE FIRE PREVENTION BUREAU AND APPROVED PRIOR TO INSTALLATION. PLANS AND INSTALLATION MUST BE BY A C16 LICENSED SPRINKLER CONTRACTOR.
2. SECTION 903.3.1.3 NFPA 13D SPRINKLER SYSTEMS AUTOMATIC FIRE SPRINKLER SYSTEMS INSTALLED IN ONE- AND TWO-FAMILY DWELLINGS, GROUP R-3.
3. SECTION 903.2.8 GROUP R AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3 SHALL BE PROVIDED THROUGHOUT ALL BUILDINGS WITH A GROUP R FIRE AREA.
4. SECTION 903.2.8.1 GROUP R-3 AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH SECTION 903.3.1.3 SHALL BE PERMITTED IN GROUP R-3 OCCUPANCIES.
5. LOCATION AND SIZE OF WATER SERVICE UNDERGROUND SHALL BE INSTALLED AS SHOWN ON APPROVED FIRE SPRINKLER PLANS. A MINIMUM 1 INCH WATER SHALL BE INSTALLED.
6. A FIRE UNDERGROUND FLUSH CERTIFICATION SHALL BE REQUIRED AT FINAL INSPECTION.
7. A HYDRO INSPECTION OF THE FIRE SPRINKLER SYSTEM IS REQUIRED PRIOR TO FRAME INSPECTION. ONLY THE NEW PIPING SHALL BE TESTED.
FIRE PROTECTION
FIRE SPRINKLERS (WHEN REQUIRED) NOTES:
DOES THE PRIMARY RESIDENCE HAVE NFPA 13D SPRINKLERS?
NO: THEREFORE, THE PROPOSED ADU IS NOT REQUIRED TO BE SPRINKLERED YES: THEREFORE, THE PROPOSED ADU IS REQUIRED TO BE SPRINKLERED (TO BE PROVIDED BY
OWNER / APPLICANT)
1. PORTIONS OF THE CITY OR COUNTY ARE LOCATED WITHIN THE WILDLANDURBAN INTERFACE. TO DETERMINE IF YOUR STRUCTURE IS LOCATED IN A WUI FIRE AREA PLEASE VISIT THE U.S. FIRE ADMINISTRATION WEBSITE:
HTTPS://SRVFIRE.MAPS.ARCGIS.COM/APPS/WEBAPPVIEWER/INDEX.HTML? ID=D55B2C2388A14733AD7FE72E86C0693E
IS YOUR STRUCTURE IN A WUI FIRE AREA?
YES NO
2. IF YOUR STRUCTURE IS LOCATED IN THE WUI FIRE AREA (EMBER ZONE OR
IGNITION ZONE), ALL CONSTRUCTION OF THE ADU STRUCTURE MUST COMPLY WITH THE CWUIC 504.
3. THIS PROTOTYPE PLAN PROVIDES DESIGNS THAT COMPLY WITH THE PROVISIONS REQUIRED BY THE CWUIC 504. PLEASE SEE APPLICABLE DETAIL SHEET(S): A-911
WILDLAND-URBAN INTERFACE FIRE AREA (WUI):
FIRE SPRINKLERS:
ADDRESS:
CONTACT:
EMAIL:
PHONE:
RRM DESIGN GROUP
3765 S HIGUERA ST, SUITE 102
SAN LUIS OBISPO, CA 93401
P:(805) 543-1794
STRUCTURAL
JESSICA MEADOWS
[email protected] FOR USE IN THE CITY OF SAN RAMON
SITE PLAN LEGEND
EASTMENT
SETBACK
PROPERTY LINE
(E) STREET NAME
OVERALL DIMENSION OF EXISTING RESIDENCE
XX' - XX"
4' - 0" MIN. SETBACK
XX' - XX" XX' - XX" XX' - XX"
OVERALL DIMENSION OF EXISTING RESIDENCE
XX' - XX" XX' - XX"
OVERALL DIMENSION OF NEW ADU
XX' - XX"
XX' - XX" FROM ADU TO (E) RESIDENCE
OVERALL DIMENSION OF EXISTING RESIDENCE
XX' - XX" XX' - XX"
XX'-XX" (DISTANCE)
(E) SINGLE FAMILY
RESIDENCE EXAMPLE
(ADDRESS)
(FOOTPRINT SF)
(N) ACCESSORY
DWELLING UNIT
EXAMPLE
SXX° XX'X"E
XX'-XX" (DISTANCE)
NXX° XX'X"W
NXX° XX'X"W (PROPERTY LINE BEARINGS)
XX'-XX" (DISTANCE)
SXX° XX'X"E
SETBACK
MIN 4'
MIN 4' - 0" SETBACK
XX' - XX"
MIN. 5' - 0" MIN. 5' - 0"
(E) PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
XX'-XX" (DISTANCE)
(E) SIDEWALK
EXAMPLE
(E) PROPERTY LINE
MIN. 4' - 0" SETBACK
XX' - XX"
(E) RETAINING WALL EXAMPLE
(DISTANCE FROM PROPERTY LINE TO (E) RESIDENCE
XX' - XX"
X XX X X X X X
(N) MECHANICAL EQUIPMENT LOCATION
EXAMPLE; NOT LESS THAN 30" OF
CLEARANCE IN WIDTH, DEPTH, & HEIGHT
SHALL BE PROVIDED TO ACCESS THE
EQUIPMENT. (2025 CMC SECTION 304.1)
(N) APPLICANT TO ILLUSTRATE AND
ANNOTATE PROPOSED APRONS,
LANDINGS, PORCHES, OVERHANGS, MECH.
/ ELEC. ITEMS AND PROPOSED ACCESS
POINTS
LOCATE ELECTRICAL (ALL) PANELS
SEE TITLE SHEET FOR PANEL OPTIONS AND
MAXIMUM AMPERAGE FOR THE PROPOSED ADU.
(E) EXISTING SWIMMING POOL
EXAMPLE (OWNER / APPLICANT
TO PROVIDE SF)
EASEMENT
EXAMPLE
(ANY/ALL
SHALL
BE
SHOWN)
SETBACK
XX' - XX"
XX' - XX"
MIN. 10'
(N) ASSUMED PROPERTY LINE
(E) SETBACK
(E) SETBACK
(E) SETBACK
XX'-XX" SETBACK
DISTANCE OF NEAREST POINT OF ADU TO CENTERLINE OF
IMAGINARY LINE BETWEEN THE TWO BUILDINGS (UNDER 5' - 0" 1- HOUR FIRE-RATED WALL AND 1-HOUR FIRE-RATED EAVE REQUIRED).
DISTANCE OF NEAREST POINT OF ADU TO
ADJACENT PROPERTY LINE (WHEN UNDER
5' - 0," 1-HOUR FIRE-RATED WALL AND 1-
HOUR FIRE-RATED RAKE/EAVE REQUIRED).
(FOOTPRINT SF)
PROVIDE ALL DIMENSIONS FOR
ALL (E) AND/OR (N) PAVED AREAS
PROVIDE ALL DIMENSIONS, OF (E) DRIVEWAY(S)
XX' - XX"
XX' - XX"
XX' - XX"
XX' - XX"
(E) FENCE EXAMPLE
(PROVIDE DIMENSIONS)
(E) FENCE EXAMPLE
(PROVIDE DIMENSIONS)
XX
(E) SIDEWALK
EXAMPLE
(CENTERLINE OF STREET)
OWNER/APPLICANT TO
INDICATE MAIN ENTRANCE
SITE PLAN CHECKLIST
DRAWING SCALE - SITE PLAN SHOULD BE DRAWN TO A MEASURABLE SCALE.
PROPERTY LINES
SHOW OUTLINE OF PROPERTY USING DASHED LINE IN LEGEND. INDICATE THE BEARING AND DISTANCE OF THE PROPERTY LINE.
LABEL YARDS
LABEL FRONT, REAR, SIDE YARDS, AS WELL AS DRIVEWAYS, PATHWAYS AND ANY OTHER HARDSCAPE.
SETBACKS
DIMENSION THE DISTANCE BETWEEN BUILDINGS AND PROPERTY LINES, AS WELL AS BUILDINGS TO OTHER STRUCTURES. SETBACKS TO SIDE AND REAR PROPERTY SIDE SHALL BE A MINIMUM OF (4' - 0").
EASEMENTS
REFER TO LEGEND. MUST INCLUDE ALL APPLICABLE EASEMENTS.
PROPOSED STRUCTURE SHALL COMPLY WITH EASEMENT REQUIREMENTS.
PROVIDE THE EXACT LOCATION AND LABEL ALL OF THE EXISTING & PROPOSED
UTILITIES ON THE SITE PLAN
A. THIS INCLUDES BUT IS NOT LIMITED TO UTILITIES, POLES, SEPTIC, SEWER, DRAINS, ELECTRICAL, GAS METERS, LINES, AND ANY PHOTOVOLTAIC.
B. INDICATE SEWER ELEVATION OF LATERAL AND MAIN CONNECTION.
IF ON SEPTIC SYSTEM, PROVIDE DEPARTMENT OF ENVIRONMENTAL
HEALTH (DEH) EXHIBIT WITH LEACH LINES SHOWN AND AREA FOR NEW LEACH LINES. SEWER MAIN EXTENSION MAY BE REQUIRED. INCLUDE
LOCATIONS AND ALL ELEVATIONS OF PROPOSED SEPTIC / SEWER / LEACH LINES. PROVIDE INVERT ELEVATIONS AT CLEANOUT, SEWER MAIN
CONNECTION, ADU CONNECTION, AND AT ANY OTHER CONNECTION POINTS.
C. PLEASE SPECIFY ON THE PLANS IF THE ADU WILL HAVE NEW
INDEPENDENT SERVICES DIRECTLY FROM THE PUBLIC RIGHT OF WAY
CONNECTION OR IF THE SERVICES WILL BE BRANCHED OFF THE EXISTING MAIN LINES ON THE PROPERTY.
D. JUSTIFY PIPE SIZES SHOWN ON THE PLAN ARE ADEQUATE FOR THE PROPOSED ADU SERVICES. IF THE SERVICES ARE CONNECTED TO THE
EXISTING MAIN SERVICES, THEN PROVIDE JUSTIFICATION THAT THE
EXISTING MAINS CAN HANDLE THE NEW INCREASED FLOWS OF THE ADU FOR WATER SUPPLY AND SANITARY SEWER SYSTEMS. PLEASE USE CPC TABLE 610.3, TABLE 610.4, AND SECTION 610.5 FOR JUSTIFICATION. NOTE,
IF USING APPENDIX A SIZING CRITERIA, PLEASE INCLUDE THE CPC APPENDIX A CHART ON THE PLAN.
LABEL STREETS & SIDEWALKS
FOOTPRINT OF PROPOSED ADU - REFER TO LEGEND FOR FOOTPRINT AT 10'=1" SCALE
DIMENSION BUILDING SEPARATION
DIMENSION THE DISTANCE BETWEEN THE PROPOSED ADU AND ANY
EXISTING STRUCTURES
AREA OF EXISTING BUILDING - INDICATE THE SQUARE FOOTAGE OF THE EXISTING HOUSE.
LOCATION OF RAIN WATER LEADERS - THE ROOF DRAINS SHOULD DRAIN AWAY FROM THE PROPERTY LINES AND INTO THE LANDSCAPE AREA.
SCALE:
1 EXAMPLE SITE PLAN /10" = 1' - 0"
SWIMMING POOLS - ALL EXISTING SWIMMING POOLS SHALL BE SHOWN ON THE SITE PLAN AND SHALL HAVE 10' MINIMUM SETBACK TO THE NEW ADU STRUCTURE.
FOOTPRINT OF ALL EXISTING AND PROPOSED BUILDINGS - PLOT THE
PROPOSED ADU BUILDING FOOTPRINT ALONG WITH ANY OTHER EXISTING BUILDINGS ONSITE. THIS INCLUDES ALL STRUCTURES / PORCHES / GAZEBOS.
PLOT ANY OPTIONAL COVERED PATIOS (WHEN SELECTED).
NORTH ARROW
PORCHES - THERE SHALL BE NO MORE THAN 30 INCHES MEASURED
VERTICALLY TO THE FLOOR OR GRADE BELOW (INCLUDING FLOORS, STAIRS, RAMPS, AND LANDINGS) ANYWHERE MEASURED LESS THAN 36 INCHES HORIZONTALLY TO THE EDGE OF THE PORCH/SLAB/SURFACE OF THE RAIL.
INSECT SCREENING SHALL NOT BE CONSIDERED AS A GUARD.
1. REFER TO GENERAL NOTES SHEET G-101 FOR ADDITIONAL REQUIREMENTS
2. REFER TO STRUCTURAL PLANS FOR FURTHER INFORMATION
3. EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY PER 2025 CRC, SECTION 308.1.
4. NOT LESS THAN 30" OF CLEARANCE IN WIDTH, DEPTH, & HEIGHT SHALL BE PROVIDED TO ACCESS EXTERIOR MECHANICAL EQUIPMENT. SHOW
LOCATION ON SITE PLAN & LABEL (2025 CMC SECTION 304.1 & 2025 CPC 504.3).
5. PROPOSED ADU IS TO BE FULLY ELECTRIC. INSTALLATION OF A GAS LINE TO THE PROPOSED ADU WILL NOT BE PERMITTED.
6. CALL BEFORE YOU DIG! CONTACT UNDERGROUND SERVICE ALERT (USA) AT 1-800-227-2600 AT LEAST 2 WORKING DAYS BEFORE EXCAVATING.
7. UNLESS OTHERWISE NOTED ON THE PLANS, FINISHED GROUND SURFACES SHALL BE GRADED TO DRAIN THE FINISHED SITE PROPERLY WITHIN 10-FEET OF ANY BUILDING FOUNDATION WITH A SLOPE OF 5% AWAY FROM ANY BUILDING OR STRUCTURE. ALL EXTERIOR HARDSCAPE WITHIN 10-FEET OF A BUILDING FOUNDATION SHALL BE INSTALLED WITH A 2% MINIMUM SLOPE AWAY FROM ANY BUILDING OR STRUCTURE. DRAINAGE SWALES SHALL BE A
1.5% MINIMUM SLOPE. ALL GRADED SLOPES SHALL HAVE A MAXIMUM SLOPE OF 3H TO 1V (33%), UNLESS SHOWN OTHERWISE ON THE PLANS.
8. LOT GRADING SHALL CONFORM AT THE PROPERTY LINES AND SHALL NOT
SLOPE TOWARD PROPERTY LINES IN A MANNER WHICH WOULD CAUSE STORM WATER TO FLOW ONTO NEIGHBORING PROPERTY. HISTORIC
DRAINAGE PATTERNS SHALL NOT BE ALTERED IN A MANNER TO CAUSE DRAINAGE PROBLEMS TO NEIGHBORING PROPERTY.
9. NEW RAINWATER DOWNSPOUTS SHALL BE DISCONNECTED AND DIRECT RUNOFF TO A LANDSCAPED AREA. DOWNSPOUTS MAY BE CONNECTED TO A
POP-UP DRAINAGE EMITTER IN THE LANDSCAPED AREA OR MAY DRAIN TO
SPLASH BLOCKS OR COBBLESTONES THAT DIRECT WATER AWAY FROM THE BUILDING.
10. CONTRACTOR TO FIELD VERIFY EXISTING DRAINAGE. IF THE EXISTING
DRAINAGE SYSTEM IS DAMAGED DURING EXCAVATION, CONTRACTOR SHALL
REPAIR AND/OR REROUTE DRAINAGE SYSTEM AND CONNECT TO EXISTING DRAINAGE FACILITY AS NECESSARY.
11. EXISTING PUBLIC IMPROVEMENTS THAT ARE DAMAGED BY THE PROJECT CONSTRUCTION SHALL BE REPAIRED OR REPLACED. EXISTING DAMAGED
PUBLIC IMPROVEMENTS WITHIN THE PROJECT LIMITS SHALL BE REPAIRED
OR REPLACED EVEN IF THE DAMAGE OCCURRED PRIOR TO THE START OF CONSTRUCTION.
12. EROSION AND SEDIMENT CONTROL FACILITIES SHALL BE INSTALLED PRIOR TO OCTOBER 1 AND SHALL BE MAINTAINED DAILY UNTIL APRIL 30. THESE
FACILITIES SHALL CONTROL AND CONTAIN EROSION-CAUSED SILT DEPOSITS
AND PROVIDE FOR THE SAFE DISCHARGE OF SILT-FREE STORM WATERS INTO EXISTING STORM DRAIN FACILITIES. EROSION AND SEDIMENT CONTROL
SUPPLIES MUST BE KEPT ON-SITE DURING THE DRY SEASON AND EMPLOYED, AS NECESSARY PRIOR TO AND DURING RAIN EVENTS.
13. SEASONALLY APPROPRIATE BEST MANAGEMENT PRACTICES FOR THE FOLLOWING SITE MANAGEMENT CATEGORIES MUST BE IMPLEMENTED YEARROUND: 1) EROSION CONTROL; 2) RUN-ON AND RUN-OFF CONTROL; 3) SEDIMENT CONTROL; 4) GOOD SITE MANAGEMENT; AND 5) NONSTORMWATER MANAGEMENT.
14. AN ENCROACHMENT PERMIT WILL BE REQUIRED FOR ANY CONSTRUCTION
ACTIVITY WITHIN A PUBLIC STREET RIGHT OF WAY THAT HAS BEEN ACCEPTED BY THE CITY.
SITE PLAN GENERAL NOTES
LOCATION OF ELECTRICAL PANEL
SEE COVER SHEET FOR PANEL OPTION AND MAXIMUM AMPERAGE FOR THE PROPOSED ADU. SEE TITLE SHEET UNDER OPTION SELECTIONS FOR REQ. ADDITIONAL CALCULATIONS BASED ON CHOSEN ELECTRICAL PANEL.
LOCATION OF FIRE HYDRANTS
INDICATE THE LOCATION OF ALL FIRE HYDRANTS WITHIN 500 FEET OF THE PROPERTY.
DRIVEWAY / PAVED ACCESS
SHOW THE PROPOSED (OR EXISTING) DRIVEWAY / PAVED ACCESS TO THE PROPOSED ADU.
TOPOGRAPHY - SHOW 1 FT CONTOURS ON SITE AND 20 FT OFFSITE. (REQUIREMENT MAY BE WAIVED AT BUILDING OFFICIALS DISCRETION.)
SHOW ALL EV CHARGING AND ALL ASSOCIATED CIRCUITS FOR NEW AND EXISTING LOCATIONS.
NOTE: THIS IS AN EXAMPLE SITE PLAN FOR AN INTERIOR
LOT. EXACT LAYOUT, DIMENSIONS, AND BEARINGS SHALL
BE PROVIDED BY OWNER/APPLICANT.
(E) EXISTING (N) NEW
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:51:52 PM
EXAMPLE SITE PLAN
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
AS-101
04/14/2026
PUBLIC SET
1-HR FIRE CONSTRUCTION
IS (N) ADU LESS THAN 5' - 0" TO ANY PROPERTY LINE AND/OR IS (N) ADU 10' - 0" OR LESS FROM ANY ADJACENT BUILDING OR STRUCTURE:
YES, IF YES, FIRE-RATED WALL REQUIRED PER 2025 CRC R302.1 AT LOCATIONS WHERE THE ADU IS LESS THAN 5' FROM THE PROPERTY LINE OR 10' FROM ANY ADJACENT BUILDING OR STRUCTURE.
FIRE RATED WALL DETAIL: 54/A-902
FIREBLOCKING IS REQUIRED IN PROJECTIONS, RAKES AND EAVES. SEE DETAILS: 41/A-905, 42/A-905, 41/A-907, 42/A-907, 41/A-909, 42/A-909, 44/A-906, 32/A-908, &44/A-910
THE FIRE-RESISTANCE RATING SHALL BE PERMITTED TO BE REDUCED TO 0 HOURS ON THE UNDERSIDE OF THE EAVE OVERHANG, IF
FIREBLOCKING IS PROVIDED FROM THE WALL TOP PLATE TO THE
UNDERSIDE OF THE ROOF SHEATHING IF ONE OF THE FOLLOWING SEPARATION DISTANCES ARE MET IN APPROPRIATE TABLE: TABLE 302.1(1) & TABLE 302.1(2).
A) NON-SPRINKLERED & FIRE SEPARATION DISTANCE PROJECTIONS ARE ≥ 2'-0" - < 5'-0"
B) SPRINKLERED & FIRE SEPARATION DISTANCE
PROJECTIONS ARE ≥ 2'
NO
DOES ANY ELEVATION ON SELECTED (N) ADU HAVE ≥ 25%
OPENINGS?
YES, THEN ARE ANY OF THOSE ELEVATIONS LESS THAN 5' FROM ANY PROPERTY LINE OR 10' OR LESS FROM ANY ADJACENT BUILDING OR STRUCTURE?
IF YES, THEN FIRE-RATED CONSTRUCTION IS REQUIRED PER 2025 CRC R302.1.
NO, NO ACTION NEEDED
FOR USE IN THE CITY OF SAN RAMON
DW
A A
3 3
C C
1 1
28' - 0"
40' - 0"
28' - 0"
KITCHEN
6 A3-202
6 A3-202
5 A3-202
5 A3-202
2 2
B B
BATH
LIVING
W.I.C.
WH
BEDROOM
6 5
8 1 2
4 4
3 6
3 5
1 2
A3-202
3 A3-202
4 A3-202
1 A3-202
HALL
10' - 7" 5' - 5" 3' - 8" 5' - 5" 2' - 11"
3' - 5 1/2" 8' - 6 1/2" 28' - 0"
EQ EQ
4' - 3" 6' - 9" 9' - 0" 3' - 9" 4' - 3"
12' - 0" 28' - 0"
COVERED PORCH
STORAGE
B01 A04 A01
A05
B05 B04
B06
14' - 0" 14' - 0"
7-3/4" MAX.
C13 A03
TYP.
M02
C08
C10
X07 G02
C01
C12
EQ EQ
7 2' - 0"
40' - 0"
1' - 10"
B38
2' - 4"
7' - 10 1/2"
3' - 7" 3' - 0"
SEE AGING-IN-PLACE 5' - 0"
DETAILS: 51/ AD-904
A06
EQ 2' - 4" EQ
EXTERIOR - 5 1/2" WOOD STUD W/ PLYWOOD SHEATHING AND
STUCCO, ONE LAYER GYPSUM WALL BOARD INTERIOR.
INTERIOR - 5 1/2" WOOD STUD W/ONE LAYER GYPSUM WALL BOARD EACH SIDE.
INTERIOR - 3 1/2" WOOD STUD W/ONE LAYER GYPSUM WALL BOARD EACH SIDE.
REFER TO DETAIL ( ) FOR ADDITIONAL INFORMATION 54/ AD-902 A2.
SOLID CORE WOOD
EXTERIOR
B.
DOUBLE SLIDING
INTERIOR
C.
SLIDING GLASS
EXTERIOR.
D.
HOLLOW CORE
WOOD INTERIOR
T T
A1.
SOLID CORE WOOD
EXTERIOR ENTRY
T
T T
RANCH CRAFTSMAN MEDITERRANEAN
A.
SINGLE HUNG.
B.
SLIDER.
EQ EQ
PER SCHED.
PER SCHED. PER SCHED.
PER SCHED.
A
2 B
COVERED PORCH
X07
G02
20' - 0"
10" 6' - 8" 12' - 6"
10"
2' - 4" 11' - 8"
14' - 0"
7 1
1 A
2 B
COVERED PORCH
X07
G02
8' - 3" 11' - 9"
2' - 0" 5' - 0" 9' - 0"
20' - 0"
16' - 0"
7 1
1 A
2 B
1' - 0" 9' - 0" 5' - 0"
8' - 3" 11' - 9"
COVERED PORCH
12" 5' - 10" 1' - 5"
7' - 10" 1' - 6"
5 1/2"
8"
8" 9' - 10" 1' - 3"
X07
G02
4' - 0" 12"
20' - 0"
15' - 0"
7 1
1 A
2 7-3/4"
MAX.
X7
BEDROOM
5' - 6"
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:51:54 PM
FLOOR PLANS
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
A3-101
04/14/2026
PUBLIC SET
A1-201 A3-101 SCALE: 1/4" = 1'-0"
1 GROUND FLOOR PLAN
NO. TYPE
DOOR
WIDTH HEIGHT REMARKS
1 A1 3' - 0" 6' - 8" 1, 2
3 A3 2' - 8" 6' - 8" 1
4 A2 2' - 8" 6' - 8" 1
5 D 3' - 0" 6' - 8"
6 D 3' - 0" 6' - 8"
8 E 2' - 8" 6' - 8"
NO. TYPE
SIZE HEAD
WIDTH HEIGHT HEIGHT REMARKS
1 B 4' - 0" 4' - 0" 6' - 8"
2 B 4' - 0" 4' - 0" 6' - 8"
3 B 4' - 0" 4' - 0" 6' - 8"
4 B 3' - 0" 3' - 0" 6' - 8" 2
5 B 3' - 0" 2' - 0" 6' - 8" 2, 4
6 B 4' - 0" 4' - 0" 6' - 8"
1. REFER TO GENERAL NOTES SHEET G-101 AND G-102 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO STRUCTURAL PLANS FOR FURTHER INFORMATION.
3. REFER TO MECHANICAL PLANS FOR FURTHER INFORMATION.
4. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
5. REFER TO PLUMBING PLANS FOR FURTHER INFORMATION.
6. ALL FURNITURE AND EQUIPMENT IS BY OWNER AND IS SHOWN FOR COORDINATION PURPOSES ONLY.
7. DIMENSIONS ARE TO FACE OF SHEATHING UNLESS SPECIFICALLY NOTED OTHERWISE.
8. PROVIDE ADEQUATE BLOCKING IN WALLS FOR CABINETS AND OTHER WALL
MOUNTED ACCESSORIES INCLUDING BUT NOT LIMITED TO HANDRAILS, SHELVING AND BATHROOM FIXTURES.
9. DOOR AND WINDOW DIMENSIONS ARE CENTERED AT OPENINGS.
10. WHERE DOOR IS LOCATED WITHOUT DIMENSION AT THE CORNER OF A ROOM IT SHALL BE 4" FROM FACE OF FRAMING OF ADJACENT WALL TO ROUGH DOOR OPENING.
11. WHERE RECESSED FIXTURES OCCUR IN WALLS OR HORIZONTAL
ASSEMBLIES, THE FIRE RATING OF THOSE ASSEMBLIES SHALL BE MAINTAINED.
12. AT ALL PENETRATIONS AND INTERSECTIONS OF FIRE-RATED PARTITIONS,
PROVIDE FIRE SEALANT AND/OR FIRE STOPPING TO MAINTAIN CONTINUITY OF PARTITION RATING.
13. PER 2025 CRC R318.3 FLOORS OR LANDINGS AT EXTERIOR DOORS SHALL BE
AT LEAST AS WIDE AS DOOR SERVED AND SHALL PROVIDE A LENGTH IN THE DIRECTION OF TRAVEL EQUAL TO 36 INCHES MINIMUM. SLOPE OF EXTERIOR LANDINGS SHALL NOT EXCEED 1/4" PER FOOT (2% SLOPE).
14. PER 2025 CRC 328.1.1 REINFORCEMENT FOR GRAB BARS SHALL BE PROVIDED IN AT LEAST ONE BATHROOM. 1. REINFORCEMENT SHALL BE
SOLID LUMBER OR OTHER CONSTRUCTION MATERIALS APPROVED BY THE ENFORCING AGENCY. 2. REINFORCEMENT SHALL NOT BE LESS THAN 2X8 INCH NOMINAL LUMBER OR OTHER MATERIAL PROVIDING EQ. HT. AND CAPACITY. REINFORCEMENT ABOVE THE FINISHED FLOOR FLUSH WITH THE WALL FRAMING. 3. WATER CLOSET REINFORCEMENT SHALL BE INSTALLED
ON BOTH SIDE WALLS OF THE FIXTURE, OR ONE SIDE WALL AND THE BACK WALL. 4. SHOWER REINFORCEMENT SHALL BE CONTINUOUS WHERE WALL FRAMING IS PROVIDED. 5. BATHTUB AND COMBINATION BATHTUB/SHOWER
REINFORCEMENT SHALL BE CONTINUOUS ON EACH END OF THE BATHTUB AND THE BACK WALL. ADDITIONALLY, BACK WALL REINFORCEMENT FOR A
LOWER GRAB BAR SHALL BE PROVIDED WITH THE BOTTOM EDGE LOCATED NO MORE THAN 6 INCHES ABOVE THE BATHTUB RIM. REFER TO SHEET A-903 FOR MORE INFORMATION.
FLOOR PLAN GENERAL NOTES
LEGEND
WINDOW SCHEDULE
DOOR SCHEDULE
KEYNOTES
1. REQUIRED EGRESS WINDOW. REFER TO WINDOW GENERAL NOTE #4 FOR ADDITIONAL INFORMATION.
2. WINDOW INCLUDES BOTH PANES TEMPERED GLAZING.
3. OPTIONAL WINDOW. SEE TITLE SHEET FOR SELECTIONS FOR MORE INFO. AT
LEAST ONE EGRESS OPENING REQUIRED AT ALL BEDROOMS, SEE GENERAL WINDOW NOTE #5 FOR EGRESS REQUIREMENTS.
4. REQUIRED TO PROVIDE OBSCURE / PRIVACY GLASS.
5. @ CASEMENT WINDOWS, INCLUDE BOTH PANES TEMPERED GLAZING.
6. MULLED WINDOW ASSEMBLY
WINDOW REMARKS
1. REFER TO PLANS FOR LOCATION OF DOORS.
2. CONTRACTOR TO VERIFY ROUGH OPENING SIZE WITH DOOR
MANUFACTURER SPECIFICATIONS PRIOR TO CONSTRUCTION.
3. CONTRACTOR TO VERIFY ACTUAL DOOR SIZE TO FIT FINISH OPENING PRIOR TO FABRICATION OF DOOR AND FINISH OPENING.
4. FIRE RATED DOORS SHALL BE SOLID WOOD OR SOLID HONEYCOMB CORE STEEL DOOR 1-3/8" THICK OR COMPLIANT WITH CRC 2025 SECTION R302.5.1.
DOORS SHALL BE SELF-CLOSING AND SELF-LATCHING WITH WEATHER STRIPPING TO BE TIGHT FITTING.
5. EXTERIOR DOORS SHALL EITHER HAVE A FIRE-RESISTANCE RATING OR MUST COMPLY WITH THE FOLLOWING REQUIREMENTS:
A. STILES AND RAILS SHALL NOT BE LESS THAN 1-3/8" THICK.
B. PANELS SHALL NOT BE LESS THAN 1-1/4" THICK, EXCEPT FOR THE
EXTERIOR PERIMETER OF THE PANEL SHALL BE PERMITTED TO TAPER TO A TONGUE OF NOT LESS THAN 3/8" THICK.
6. GLAZING IN DOORS SHALL BE TEMPERED PER CRC 2025 SECTION R324.4.1.
PANES INDICATED IN DOOR LEGEND WITH (T).
7. IF STRUCTURE, IS IN A WUI ZONE OR FHSZ, DOOR MUST COMPLY WITH CWUIC 2025 SEC. 504.9
DOOR GENERAL NOTES
DOOR LEGEND
WINDOW LEGEND
A01 30" WIDE FREE STANDING ELECTRIC RANGE OVEN. VENT TO EXTERIOR, STAINLESS STEEL.
A03 30" WIDE BUILT-IN MICROWAVE WITH RANGE VENT, STAINLESS STEEL.
A04 24" WIDE FRONT CONTROL UNDERCOUNTER DISHWASHER.
A05 REFRIGERATOR LOCATION. PROVIDE 36" SPACE WITH ROUGH PLUMBING FOR ICE MAKER (RECESS IN WALL) OR PER OWNER'S SPECIFICATIONS.
A06 STACKED WASHER/DRYER MACHINE LOCATION. PROVIDE WASTE AND WATER IN RECESSED WALL BOX. PROVIDE DRYER VENT. VENT TO OUTSIDE AIR.
B01 30" SINGLE COMPARTMENT UNDER-MOUNT KITCHEN SINK W/ GARBAGE DISPOSAL. REFER TO WATER EFFICIENCY REQUIREMENTS ON CALGREEN CODE NOTES SHEET.
B04 LAVATORY SINK. REFER TO WATER EFFICIENCY REQUIREMENTS ON CALGREEN CODE NOTES SHEETS.
B05 WATER CLOSET. REFER TO WATER EFFICIENCY REQUIREMENTS ON CALGREEN CODE NOTES SHEETS.
B06 32" x 60" x 72" TUB AND SHOWER COMBINATION. MODEL BY BUILDER.
PROVIDE SHOWER ROD.
B38 MULTI-ZONE HEAT PUMP CONDENSING UNIT. REFER TO PLANS FOR LOCATION OF INDOOR FAN FAN COIL UNITS. REFER TO TITLE 24 FOR ADDITIONAL INFORMATION. PROVIDE CONCRETE PAD MIN. 6" LARGER THAN UNIT IN EACH DIRECTION, 3" MIN. ABOVE GRADE.
C01 SINGLE WOOD SHELF AND POLE.
C08 12" DEEP UPPER CABINET
C10 24" DEEP UPPER CABINET.
C12 34 1/2" HIGH BASE CABINET AND COUNTERTOP.
C13 30" HIGH BASE CABINET AND COUNTERTOP.
G02 CONCRETE FLATWORK. 1/4"/FT SLOPE AWAY FROM BUILDING.
M02 DOWNSPOUT. CONNECT TO STORM DRAIN SYSTEM
X07 PORCH LAYOUT VARIES BY SELECTED STYLE. REFER TO STYLE SPECIFIC PORCH PLANS.
A1-201 A3-101 SCALE: 1/4" = 1'-0"
2 PORCH-SUBURBAN RANCH
A1-201 A3-101 SCALE: 1/4" = 1'-0"
3 PORCH-CRAFTSMAN
A1-201 A3-101 SCALE: 1/4" = 1'-0"
4 PORCH-MEDITERRANEAN
A1-201 A3-101 SCALE: 1/4" = 1'-0"
OPTIONAL SLIDING
5 DOOR @ BEDROOM
NO. TYPE
SIZE HEAD
WIDTH HEIGHT HEIGHT REMARKS
7 A 6' - 0" 5' - 0" 8' - 8" 1, 3
OPTIONAL WINDOWS
NO. TYPE
DOOR
WIDTH HEIGHT REMARKS
X7 C 5' - 0" 6' - 8" 1, 2, 4
OPTIONAL DOORS
1. EXTERIOR DOOR.
2. GLAZING PER DOOR TYPES. REFER TO GENERAL DOOR NOTE #6
3. REQUIRED OPENING OF NOT LESS THAN 100 IN2 FOR MAKEUP AIR SHALL BE PROVIDED IN THE DOOR OR BY APPROVED MEANS. [CMC SEC. R504.4.1]
4. VENT DOOR AS REQUIRED PER WATER HEATER MANUFACTURER
REQUIREMENTS / SPECIFICATIONS
5. OPTIONAL DOOR.
DOOR REMARKS
1. REFER TO FLOOR PLANS FOR WINDOW LOCATIONS.
2. CONTRACTOR TO VERIFY EXACT ROUGH OPENING SIZES PRIOR TO FABRICATION OF ROUGH OPENINGS.
3. ALL GLAZING IS DOUBLE PANE UNLESS OTHERWISE NOTED.
4. EGRESS WINDOWS SHALL HAVE A CLEAR OPENING WITH THE BOTTOM OF THE CLEAR OPENING NOT GREATER THAN 44" AFF, MIN. NET CLEAR OPENING FOR EMERGENCY ESCAPE SHALL BE 5.7 S.F. EXCEPT: 5 S.F. MIN. AT GROUND FLOOR. MINIMUM NET CLEAR OPENING DIMENSIONS: HEIGHT: 24", WIDTH: 20". [CRC SEC. R310.2] EMERGENCY ESCAPE AND RESCUE OPENINGS SHALL OPEN DIRECTLY INTO A PUBLIC WAY PER CRC 2025, SECTION 310.1.
5. GLAZING IN WALLS ADJACENT TO BATHTUB / SHOWER WHERE THE BOTTOM EXPOSED EDGE OF THE GLAZING IS LESS THAN 60" MEASURED VERTICALLY ABOVE ANY STANDING OR WALKING SURFACE SHALL BE SAFETY GLAZING. [CRC SEC. R324.4.5]
6. REFER TO WINDOW SCHEDULE AND WINDOW LEGEND FOR MORE
INFORMATION.
7. IF STRUCTURE IS IN A WUI ZONE OR FHSZ, WINDOW MUST COMPLY WITH CWUIC SECTION 504.8
WINDOW GENERAL NOTES
8. REFER TO ENERGY COMPLIANCE REPORTS TO VERIFY U-FACTOR, SHGC AND ADDITIONAL WINDOW REQUIREMENTS. ALL OPENINGS TO BE
U-FACTOR = (.3) , SHGC = (.23). BUG SCREEN REQUIRED (PER TITLE 24).
FOR USE IN THE CITY OF SAN RAMON
DW
LUXURY VINYL PLANK
(LVT)
FINISH LEGEND
CARPET
(CPT)
CERAMIC TILE
(CT)
CONCRETE
(EC)
KITCHEN LIVING
BATH
HALL
WH
W.I.C.
BEDROOM
COVERED PORCH
STORAGE
A1-201 A3-111 SCALE: 1/4" = 1'-0" 1 GROUND FLOOR FINISH PLAN DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:51:54 PM
FINISH PLANS
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
A3-111
04/14/2026
PUBLIC SET
FINISH SCHEDULE
1. REFER TO GENERAL NOTES SHEET G-101 AND G-102 FOR ADDITIONAL REQUIREMENTS.
2. REFER TO ELECTRICAL PLANS FOR FURTHER INFORMATION.
3. REFER TO PLUMBING PLANS FOR FURTHER INFORMATION.
4. REFER TO DETAILS FOR FLOOR/CEILING ASSEMBLIES AND INTERIOR FINISH DETAILS.
5. ALL HARD SURFACE FLOORING SHALL BE SLIP RESISTANT AND MEET THE ANSI A326.3 STANDARD FOR MEASURING THE DYNAMIC COEFFICIENT OF FRICTION (DCOF).
6. ALL FLOORING MATERIALS SHALL COMPLY WITH 2025 CBC SEC. 804.1.
7. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2025 CBC TABLE 803.13 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
FINISH PLAN GENERAL NOTES
NAME FLOOR WALL CEILING NOTES
KITCHEN LVT GWB GWB WR GWB BEHIND COUNTER
LIVING LVT GWB GWB
BATH CT WR GWB WR GWB IF CERAMIC TILE IS PROVIDED IN
TUB/SHOWER AREAS, PROVIDE
BACKER BOARDS PER CRC R702.4.2
W.I.C. CPT GWB GWB
WH EC GWB GWB
BEDROOM CPT GWB GWB
HALL LVT GWB GWB
STORAGE EC GWB GWB FOR USE IN THE CITY OF SAN RAMON
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
3 2 1
K11 K04 K03 L15 K13 K05
B14 B38
B18
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
C B A BOTT OF HDR 7' - 0"
54 AD-909
K05 H08
M01
M02
K03 L15
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
1 2 3 BOTT OF HDR 7' - 0"
K03 K05 L15 K13 K11
14 AD-909
21 AD-909
34 AD-909
54 AD-909
± 11' - 4"
AD-909
51 01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
A B C
M01
M02
K05 K03 K11 L15 K13
AD-909
21 01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
C B A
T02
S04
KITCHEN COVERED PORCH
ATTIC
2' - 6"
ALLOW AIRFLOW
ATTIC ACCESS REQ.
PER CRC R807
OPTIONAL WINDOW
01-GROUND FLOOR
0' - 0"
01-PLATE
8' - 1"
1 2 3
LIVING HALL W/D WH T02
S04
T01
ATTIC
KITCHEN
G14
S03
LEGEND
3-COAT CEMENT PLASTER
CEMENTITOUS LAP SIDING
CEMENTITOUS BOARD AND BATTEN SIDING
CEMENTITOUS SHINGLE SIDING
DATE
SHEET
THESE PLANS ARE PROVIDED BY THE CITY OF SAN RAMON
AS PART OF THE PRE-APPROVED ADU PROGRAM AND ARE
PUBLIC DOMAIN. THERE CANNOT BE A CHARGE TO
PROVIDE THESE PLANS. NO ALTERATIONS TO THESE PLANS
ARE ALLOWED. ALL ALTERATIONS MUST BE DONE UNDER A
SEPARATE PERMIT ONCE THE BUILDING PERMIT FOR THE
ADU HAS BEEN ISSUED AND FINAL INSPECTION
COMPLETED. IF YOU DO NOT HAVE THE CONSTRUCTION
KNOWLEDGE AND EXPERIENCE TO CONTRUCT THESE
PLANS WITHOUT FURTHER DETAILS, IT IS RECOMMENDED
YOU HIRE A CONTRACTOR TO DO THE CONSTRUCTION.
THE CITY WILL NOT PROVIDE FURTHER INFORMATION OR
DETAILS AND BUILDING INSPECTORS WILL NOT PROVIDE
STEP BY STEP INSTRUCTIONS IN THE FIELD.
NO. REVISION DATE
Autodesk Docs://2208-03_San Ramon ADU Code Update/2208-03_San Ramon ADU Code Update.rvt 4/15/2026 3:51:58 PM
EXTERIOR ELEVATIONS &
BUILDING SECTIONS-SUBURBAN
RANCH
SAN RAMON ADU PROTOTYPES
SAN RAMON, CA
A3-203
04/14/2026
PUBLIC SET
A3-203 SCALE: 1/4" = 1'-0"
1 PLAN 3 - SUBURBAN RANCH - REAR
A3-203 SCALE: 1/4" = 1'-0"
2 PLAN 3 - SUBURBAN RANCH - RIGHT
A3-203 SCALE: 1/4" = 1'-0"
3 PLAN 3 - SUBURBAN RANCH - FRONT
A3-203 SCALE: 1/4" = 1'-0"
4 PLAN 3 - SUBURBAN RANCH - LEFT
A3-123 A3-203 SCALE: 1/4" = 1'-0"
6 PLAN 3 - SUBURBAN RANCH- SECTION 2
A3-123 A3-203 SCALE: 1/4" = 1'-0"
5 PLAN 3 - SUBURBAN RANCH - SECTION 1
KEYNOTES
B14 50 GALLON TANK TYPE ELECTRIC WATER HEATER. REFER TO TITLE 24 FOR ADDITIONAL INFORMATION. PROVIDE CONCRETE PAD MIN. 6" LARGER THAN UNIT IN EACH DIRECTION. 3" MIN. ABOVE GRADE. ENCLOSURE REQUIRED WHEN OUTDOORS.
B18 ELECTRIC PANEL TBD.
B38 MULTI-ZONE HEAT PUMP CONDENSING UNIT. REFER TO PLANS FOR LOCATION OF INDOOR FAN FAN COIL UNITS. REFER TO TITLE 24 FOR ADDITIONAL INFORMATION. PROVIDE CONCRETE PAD MIN. 6" LARGER THAN UNIT IN EACH DIRECTION, 3" MIN. ABOVE GRADE.
G14 4" CONCRETE SLAB ON GRADE, REFER TO STUCTURAL PLANS H08 ATTIC VENT. PAINT FINISH TO MATCH ROOF COLOR. REFER TO COLORS AND MATERIALS.
K03 ADHERED VENEER SIDING - REFER TO COLOR SCHEME ON COLOR MATERIALS BOARD FOR REFERENCE.
K04 FIBER CEMENT BOARD AND BATTEN SIDING, IN COMPLIANCE WITH 2025 CWUIC 504
K05 CLASS A ASPHALT COMPOSITE ROOF SHINGLES. GAF TIMBERLINE HD OR APROVED EQUAL. THE USE OF CLASS A TILE ROOFING IS ALSO ALLOWED AND HAS BEEN ACCOUNTED FOR IN STRUCTURAL ROOF LOADS.
K11 DOOR PER PLAN
K13 WINDOW PER PLAN
L15 WIN/DOOR SURROUNDS
M01 GUTTER. CONNECT TO DOWNSPOUT. PROVIDE MEANS TO PREVENT ACCUMULATION OF LEAVES AND DEBRIS IN GUTTER PER CRC R327.5.4 M02 DOWNSPOUT. CONNECT TO STORM DRAIN SYSTEM
S03 ROOF INSULATION. REFER TO TITLE 24 (R-38 MIN.).
S04 2X6 WALL INSULATION. REFER TO TITLE 24 (R-21 MIN.)
T01 2X4 WOOD STUD WALL. REFER TO STRUCTURAL.
T02 2X6 WOOD STUD WALL. REFER TO STRUCTURAL.
1. REFER TO GENERAL NOTES SHEET G-101 & G-102 FOR ADDITIONAL
REQUIREMENTS
2. SEE DETAILS FOR ADDITIONAL INFORMATION AND REQUIREMENTS.
3. REFER TO ROOF PLAN FOR OVERHANGS. FASCIA PER DETAILS. PROVIDE ALUMINUM GUTTER. SEE ROOF PLAN FOR APPROXIMATE DOWNSPOUT LOCATIONS, U.N.O.
4. REFER TO DOOR AND WINDOW SCHEDULES AND TYPES FOR DOOR AND WINDOW INFORMATION.
5. THE NOMINAL THICKNESS AND ATTACHMENT OF EXTERIOR WALL COVERINGS SHALL BE IN ACCORDANCE WITH 2025 CRC TABLE R703.3(1).
6. GYPSUM SHEATHING SHALL BE ATTACHED TO EXTERIOR WALLS IN ACCORDANCE WITH 2025 CRC TABLE R602.3 (1).
7. CLADDING ATTACHMENT OVER FOAM SHEATHING TO WOOD FRAMING IN ACCORDANCE WITH 2025 CRC R703.15. REFER TO 2025 CRC R703.8 FOR
ANCHORED MASONRY OR STONE VENEER INSTALLED OVER FOAM
SHEATHING.
ELEVATION GENERAL NOTES
1. THE PURPOSE OF THESE DRAWINGS IS TO SHOW CONSTRUCTION MATERIALS/ASSEMBLIES. FOR SPECIFIC SIZES AND DETAILS REFER TO ARCHITECTURAL PLANS, ELEVATIONS, DETAILS, AND STRUCTURAL PLANS. *KEYNOTES ONLY APPLY IF REFERENCED ON PLANS.
2. WALL ASSEMBLIES TO BE PER FLOOR PLAN.
3. DOORS AND WINDOWS TO BE PER APPLICABLE SCHEDULE. REFER TO FLOOR PLANS FOR IDENTIFICATION.
4. INSULATION: REFER TO TITLE 24 REPORT AND "INSULATION" NOTES ON SHEET FOR ADDITIONAL RATINGS, REQUIREMENTS, AND INFORMATION.
5. FIREBLOCKING TO BE LOCATED PER 2025 CRC SECTION R302.11:
A. SECTION R302.11 -
1. FIREBLOCKING SHALL BE PROVIDED IN CONCEALED SPACES OF
STUD WALLS AND PARTITIONS, INCLUDING FURRED SPACES AND
PARALLEL ROWS OF STUDS OR STAGGERED STUDS, AS FOLLOWS:
1. VERTICALLY AT CEILING AND FLOOR LEVELS
2. HORIZONTALLY AT INTERVALS NOT EXCEEDING 10 FEET.
2. AT INTERCONNECTIONS BETWEEN CONCEALED VERTICAL AND
HORIZONTAL SPACES SUCH AS SOFFITS, DROP CEILINGS AND COVE CEILINGS.
3. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT THE TOP AND BOTTOM OF THE RUN. ENCLOSED SPACES UNDER STAIRS
SHALL COMPLY WITH 2025 CRC SECTION R302.7.
4. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES AND WIRES AT
CEILINGS AND FLOOR LEVEL, WITH AN APPROVED MATERIAL TO
RESIST THE FREE PASSAGE OF FLAME PRODUCTS OF COMBUSTION.
THE MATERIAL FILLING THIS ANNULAR SPACE SHALL NOT BE
REQUIRED TO MEET THE ASTM E136 REQUIREMENTS.
5. FOR THE FIREBLOCKING OF CHIMNEYS AND FIREPLACES, SEE 2025 CRC SECTION R1003.19.
6. FIREBLOCKING OF CORNICES OF A TWO-FAMILY DWELLING IS REQUIRED AT THE LINE OF DWELLING-UNIT SEPARATION.
B. SECTION R302.11.1 - FIREBLOCKING MATERIALS SHALL CONSIST OF FOLLOWING MATERIALS:
1. TWO-INCH NOMINAL LUMBER
2. TWO THICKNESSES OF ONE-INCH NOMINAL LUMBER WITH BROKEN
LAP JOINTS
3. THE THICKNESS OF 0.719-INCH WOOD STRUCTURAL PANELS WITH JOINTS BACKED BY 0.719-INCH WOOD STRUCTURAL PANELS
4. THE THICKNESS OF 0.75-INCH PARTICLE BOARD WITH JOINTS BACKED BY 0.75-INCH PARTICLE BOARD
5. ONE-HALF-INCH GYPSUM BOARD
6. ONE-FOURTH-INCH CEMENT-BASED MILLBOARD
7. BATTS OR BLANKETS OF MINERAL WOOL, MINERAL FIBER OR OTHER
APPROVED MATERIAL INSTALLED IN SUCH A MANNER AS TO BE
SECURELY RETAINED IN PLACE
8. CELLULOSE INSULATION INSTALLED AS TESTED IN ACCORDANCE WITH ASTM E119 OR UL 263, FOR THE SPECIFIC APPLICATION.
6. PER 2025 CRC SECTION R304.1 SLEEPERS AND SILLS ON A CONCRETE OR
MASONRY SLAB THAT IS IN DIRECT CONTACT WITH GROUND, UNLESS
SEPARATED BY AN IMPERVIOUS MOISTURE BARRIER SHALL BE NATURALLY
DURABLE OR PRESERVATIVE-TREATED WOOD IN ACCORDANCE WITH AWPA U1.
7. REFER TO RCP'S FOR SOFFIT DIMENSIONS AND FURTHER INFORMATION.
8. PROVIDE BLOCKING FOR ALL WALLS WHERE WALL HUNG EQUIPMENT AND FIXTURES OCCUR.
9. ALL WALL AND CEILING FINISHES SHALL COMPLY WITH 2025 CRC 302.9 FOR MAXIMUM FLAME SPREAD AND SMOKE DENSITY.
SECTIONS GENERAL NOTES
FOR USE IN THE CITY OF SAN RAMON
City Council Staff Report
Item No. 5.9.
Date: July 14, 2026
To: San Ramon City Council
From: Brian Bornstein, Department Director
Christopher Low, Associate Engineer
Subject: Resolution No. 2026-103 - Accepting Parcel C of Subdivision 9326 for Ownership and Maintenance of Park Acceptance 0018, Critter Crossroads Park, and Authorizing the City Manager to Execute All Necessary Documents to Effectuate the Transfer of Ownership (Shapell Industries, Inc./Toll Brothers)
Executive Summary:
The Dougherty Valley is a master-planned community located east of Alcosta Boulevard and includes the Gale Ranch and Windemere developments. Approved by Contra Costa County, the Dougherty Valley is developed under the terms of the Dougherty Valley Settlement Agreement and Dougherty Valley Memorandum of Understanding (MOU).
Park Acceptance (PA) 0018, Critter Crossroads Park, is an approximate 8.71-acre park located at the intersection of Main Branch Road and South Gale Ridge Road in Gale Ranch.
The Contra Costa County Board of Supervisors has adopted the resolution for the completion of improvements. Staff recommends execution of the property transfer documents from Shapell Industries, Inc. and acceptance of the improvements for ownership and maintenance as obligated by the Dougherty Valley MOU.
Recommendation:
The City Council’s role is to consider approval of this Resolution, accepting Parcel C of Subdivision 9326 for ownership and maintenance of PA 0018, Critter Crossroads Park, and authorizing the City Manager to execute all necessary documents to effectuate the transfer of ownership (Shapell Industries, Inc./Toll Brothers).
Background:
The Dougherty Valley is a master-planned community of approximately 11,000 units that was approved in 1994 by Contra Costa County. The community is developed under the terms of the Dougherty Valley Settlement Agreement and Dougherty Valley MOU. The Settlement Agreement and MOU establish the framework governing the planning, processing, and development of Dougherty Valley. The parties to these agreements include Contra Costa County (County), City of San Ramon (City), Town of Danville, and the Dougherty Valley developers, Windemere BLC and Shapell Homes.
The purpose of the MOU, executed in 1998, is to:
• outline the roles and responsibilities of the agencies involved in the processing, completion, operation, and maintenance of the Dougherty Valley Development (Project);
• detail procedures for distributing property taxes and special assessments collected; • ensure that the ownership of and responsibility for maintaining public improvements for the Project is efficiently and effectively transferred from the County to the City; and
• ensure that the annexation of property from County to City takes place in a cooperative manner.
The Settlement Agreement, executed in 1994, also memorializes provisions to ensure orderly development, annexation, operation, and maintenance of facilities and infrastructure, and delivery of public services in accordance with certain standards agreed to by all parties.
This Agreement resolves all previous claims between the City and Town of Danville and establishes a mutually agreed upon framework for the orderly development of Dougherty Valley.
Per the Settlement Agreement, Contra Costa County is the lead agency for processing the development approvals in Dougherty Valley. These development approvals lead to the construction of roadways and drainage improvements, landscape improvements, parks, trails, and community facilities. In accordance with the Settlement Agreement and MOU, the County distributes the development plans to the City for review and comment. The County approves the plans and determines when the public improvements are complete, authorizes bond reductions, and if applicable to the project, begins a warranty period. The City typically conducts periodic joint inspections with the County and gives its concurrence for acceptance prior to the County taking action. With the joint agreement that the improvements are acceptable, the County proceeds with acceptance through the County Board of Supervisors. Under notice that the County has accepted the improvements, and upon request of the developer, the City then proceeds with acceptance by the City Council.
For landscape improvements, City acceptance occurs after the completion of the warranty period, which is generally one year. Once the City Council has accepted the improvements and associated land dedications, the City takes full ownership and maintenance of the
improvements.
To date, the City has accepted for maintenance:
• Road and storm drain improvements for 76 subdivisions; • Road and storm drain improvements for 59 road acceptances; • Landscape improvements for 80 subdivisions;
• Landscape improvements for 47 road acceptances;
• 33 parks and school parks, including Rancho San Ramon Community Park, the Amador Rancho Center, and landscape at Dougherty Valley High School; • Site and landscape improvements at the Dougherty Station Community Center/Library;
• Site improvements at the Dougherty Valley Service Center and the Amador Rancho Center;
• West Alamo Creek Trail, Tassajara Ridge Trail, Windemere Ridge Trail, Live Oak Trail, Monarch Ridge Trail, Monarch Loop Trail, Star Jasmine Trail, Sycamore Grove Trail, Rolling Hills Trail, Basswood Trail, Old Dougherty Road Trail, a portion of the Alamo Creek Trail, Dougherty Valley Ridge Trail, Coyote Canyon Trail, Quail Run Trail, Jack Rabbit Ridge Trail, Overlook Park, and surrounding landscape improvements in Gale Ranch;
• The water fountain landscape entry feature on Bollinger Canyon Road; • Gale Ranch Community Identification Monument improvements on Bollinger Canyon Road;
• Windemere Tower improvements on Bollinger Canyon Road at Dougherty Valley High School;
• Windemere Entry Sign improvements on Bollinger Canyon Road near the Dougherty Station Community Center/Library;
• Creek improvements in portions of the Main Branch and West Branch of Alamo Creek, and designated mitigation creeks;
• Water Quality Ponds W3, W4, M1A and M2A, and Bioswales W1 and W2 in Gale Ranch;
• Water Quality Ponds 1-9, 11, and 14 plus Pond 14 Outfall, and detention basin DA 0005 in Windemere; and
• Miscellaneous storm drain improvements for four (4) drainage acceptances.
To date, the City has accepted approximately 75 miles of roadway, approximately 229 acres of public landscape, 128 acres of park area, and approximately 21.3 miles of trails.
Discussion:
Contra Costa County has designated Parcel C of Subdivision 9326 as PA 0018. On December 11, 2019, the City of San Ramon Parks and Community Services Commission adopted the name for PA 0018 as “Critter Crossroads Park.” Critter Crossroads Park is approximately
8.71-acres and is located at the intersection of Main Branch Road and South Gale Ridge Road (Attachment B).
Improvements at Critter Crossroads Park include a baseball/softball field; separate playgrounds for children ages 2–5 and 5–12 featuring critter-themed play equipment; game tables; exercise stations; a sand volleyball area; a multi-purpose lawn area; shade structures; BBQ and picnic areas; a decorative concrete labyrinth; restroom facilities; a parking lot; and landscaping. Photos of the park are included in Attachment C.
During the filing of the Final Map of Subdivision 9326, Parcel C was retained by the owner for park purposes; however, a formal dedication of the park for public purposes was not made on the map. Shapell Industries, Inc. will provide a Grant Deed to the City for the park parcel.
On July 7, 2026, the Contra Costa County Board of Supervisors adopted Resolution No. 2026/254 accepting completion of improvements for PA 0018 (Attachment D).
Fiscal Impact:
Upon acceptance, the City will incur certain maintenance responsibilities that are estimated to cost $87,122 annually. These estimated annual costs include: $47,122 for contracted maintenance services (landscape, janitorial, grub control), materials, and supplies; $39,000 for water utilities; and $1,000 for electrical utilities which have already been built into the FY27 Dougherty Valley Fund budget.
While funding for the annual maintenance costs is to be reimbursed by the County Service Area (CSA) M-29 assessment for Dougherty Valley, in FY27 the assessment is almost $5m short of covering the cost of services and the General Fund is required to subsidize operations. As a result, adding maintenance costs to the CSA M-29, increases costs to the General Fund.
The estimated total cost of park improvements is $4,117,000.
Alternative Option(s):
The City Council can choose to decline to approve the Resolution, and the project will remain private property. However, the City would be in violation of the Dougherty Valley Settlement Agreement and MOU.
Next Steps:
The executed copy of the City Council Resolution and the Grant Deed for the parcel will be recorded at the Contra Costa County Recorder’s Office. The Public Services Division within Public Works will coordinate with the developer to transfer the utility bills and begin maintenance of these park improvements on July 15, 2026.
Attachment(s):
A. Resolution 2026-103
B. Location Map
C. Project Photos
D. Contra Costa County Board of Supervisors Resolution No. 2026/254
ATTACHMENT A
RESOLUTION NO. 2026-103
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SAN RAMON ACCEPTING PARCEL C OF SUBDIVISION 9326 FOR OWNERSHIP AND MAINTENANCE OF PARK ACCEPTANCE 0018, CRITTER CROSSROADS PARK, AND AUTHORIZING THE
CITY MANAGER TO EXECUTE ALL NECESSARY DOCUMENTS TO EFFECTUATE THE TRANSFER OF OWNERSHIP (SHAPELL INDUSTRIES, INC./TOLL BROTHERS) WHEREAS, the Contra Costa County Board of Supervisors approved the Final Map for Subdivision 9326 containing certain road, storm drain, and park improvement requirements for this subdivision; and
WHEREAS, Contra Costa County, in coordination with the City of San Ramon, has designated Park Acceptance (PA) 0018 as Critter Crossroads Park; and WHEREAS, Critter Crossroads Park is approximately 8.71 acres and contained on Parcel C of Subdivision 9326; and
WHEREAS, Parcel C of Subdivision 9326 was retained by Shapell Industries, Inc. on the Final Map for Subdivision 9326 for the development of PA 0018; and WHEREAS, Shapell Industries, Inc. has provided the transfer of ownership documents to the City for Parcel C of Subdivision 9326; and WHEREAS, improvements at Critter Crossroads Park includes a softball field, playgrounds for children ages 2-5 and 5-12 featuring critter themed play equipment, game tables, exercise stations, a sand volleyball area, multi-purpose lawn area, shade structures, BBQ and picnic areas, a decorative concrete labyrinth, restroom facilities, parking lot, and landscape; and.
WHEREAS, the public park improvements have been constructed and inspected to be consistent with the provisions of the Memorandum of Understanding dated October 15, 1997 between Contra Costa County, the City of San Ramon, Shapell Industries, Inc., and Windemere Ranch Partners; and
WHEREAS, the Contra Costa County Public Works Department has determined that the park improvements have been completed by Shapell Industries, Inc./Toll Brothers and has recommended that the Contra Costa County Board of Supervisors accept the park improvements as complete; and
WHEREAS, the Board of Supervisors adopted Resolution No. 2026/254 on July 7, 2026 accepting the park improvements as complete and establishing the start of the oneyear warranty period for Critter Crossroads Park; and
Resolution No. 2026-103
WHEREAS, the City Engineer has determined that the public park improvements are complete and ready for acceptance by the City for ownership and maintenance; and WHEREAS, pursuant to the Memorandum of Understanding, the City of San Ramon is obligated to accept ownership of the public park improvements upon competition or initiation of the annexation process; and
WHEREAS, the annexation process for the area that contains PA 0018 (Critter Crossroads Park) was completed the Local Agency Formation Committee (LAFCO) on October 14, 2020 under LAFCO Resolution No. 2020-05.
NOW, THEREFORE, BE IT RESOLVED, that the City Council of the City of San Ramon hereby:
1. Accepts the park improvements as shown on the final As-Built drawings entitled “Improvement Plans, Park Acceptance 0018, Parcel C, Subdivision 9326, Critter Crossroads Park, City of San Ramon, Contra Costa County, California.”
2. Authorizes the City Manager to execute all necessary documents to effectuate the transfer of ownership.
PASSED, APPROVED, AND ADOPTED, at the meeting of July 14, 2026, by the following votes:
AYES:
NOES:
ABSENT:
ABSTAIN:
________________________________
Mark Armstrong, Mayor
ATTEST:
Joan Snashall, City Clerk
0 PARCEL C, SUBD 9326
I
I
I
I
I
I
I
/
/�
I
I
.,
LOCATION MAP
GALE RANCH
CRITTER CROSSROADS PARK (PA 0018)
PARK ACCEPTANCE IMPROVEMENTS
,.
o, I
�
San Ramon
PUBLIC WORKS
ATTACHMENT B
PA 0018 (CRITTER CROSSROADS PARK)
PROJECT PHOTOS
Photo 1
Fitness Area
Photo 2
BBQ Area with Shade Structure
Photo 3
Baseball Field
Photo 4
Sand Volleyball Court
ATTACHMENT C
PA 0018 (CRITTER CROSSROADS PARK)
PROJECT PHOTOS
Photo 5
Decorative Concrete Labyrinth
Photo 6
Table Tennis
Photo 7
Play Structure
Photo 8
Critter (Salamander) Play Equipment
CONTRA COSTA COUNTY
Legislation Text
1025 ESCOBAR STREET
MARTINEZ, CA 94553
To: Board of Supervisors
From: Warren Lai, Public Works Director/Chief Engineer
Report Title: Accepting completion of landscape improvements for the Subdivision Agreement for park acceptance PA04-00018 (cross-reference subdivision SD16-09326), San Ramon (Dougherty Valley) area. ☒Recommendation of the County Administrator ☐ Recommendation of Board Committee RECOMMENDATIONS:
ADOPT Resolution accepting completion of improvements for the Subdivision Agreement (Right-of-Way Landscaping) park acceptance PA04-00018 (cross-reference subdivision SD16-09326), for a project developed by Shapell Industries, Inc., as recommended by the Public Works Director, San Ramon (Dougherty Valley) area. (District II)
FISCAL IMPACT:
No fiscal impact.
BACKGROUND:
The developer has completed the landscape improvements per the Subdivision Agreement (Right-of-Way Landscaping), and in accordance with Title 9 of the County Ordinance Code.
CONSEQUENCE OF NEGATIVE ACTION:
The completion of improvements will not be accepted, and the maintenance/warranty period will not begin.
C: Alex Vazquez-Engineering Services, Jesse Ma-Engineering Services, Kellen O’Connor-Engineering Services, Paul Tehaney, Design/Construction, Chis Hallford-Mapping, Chris Low-City of San Ramon, Toll Brother, Inc, Fidelity and Deposit Company of Maryland, T-5/7/27 File #: RES 2026-254, Version: 1
CONTRA COSTA COUNTY Page 1 of 2 Printed on 7/2/2026
powered by Legistar™
ATTACHMENT D
File #: RES 2026-254, Version: 1
THE BOARD OF SUPERVISORS OF CONTRA COSTA COUNTY, CALIFORNIA and for Special Districts, Agencies and Authorities Governed by the Board IN THE MATTER OF: Accepting completion of improvements for the Subdivision Agreement (Right-of-Way Landscaping) park acceptance PA04-00018 (cross-reference subdivision SD16-09326), for a project developed by Shapell Industries, Inc., as recommended by the Public Works Director, San Ramon (Dougherty Valley) area. (District II)
WHEREAS, these improvements are approximately located near South Monarch Road and Main Branch Road.
WHEREAS, the Public Works Director has notified this Board that the Right of Way Landscaping Improvements for PA04-00018 (cross-reference subdivision SD 16-09326), have been completed as provided in the Subdivision Agreement (Right of Way Landscaping) with Shapell Industries, Inc., heretofore approved by this Board;
NOW, THEREFORE, BE IT RESOLVED that the landscape improvements have been COMPLETED as of July 7, 2026, thereby establishing the six-month terminal period for the filing of liens in case of action under said Subdivision Agreement (Right of Way Landscaping):
DATE OF AGREEMENT
September 7, 2021
NAME OF SURETY
Fidelity and Deposit Company of Maryland
BE IT FURTHER RESOLVED the payment (labor and materials) surety for $2,058,500, Bond No. 9304036 issued by the above surety be RETAINED for the six-month lien guarantee period until January 7, 23, 2027, at which time the Board AUTHORIZES the release of said surety less the amount of any claims on file.
BE IT FURTHER RESOLVED that upon acceptance by the Board of Supervisors, the San Ramon City Council shall accept the landscape improvements for maintenance in accordance with the Dougherty Valley Memorandum of Understanding.
BE IT FURTHER RESOLVED that the beginning of the warranty and maintenance period is hereby established, and the $41,170.00 cash deposit (Auditor's Deposit Permit No. 832928, dated July 29, 2021) submitted by Toll Brothers, Inc., and the performance/maintenance surety bond rider for $61,7550, Bond No. 9304036 issued by Fidelity and Deposit Company of Maryland be RETAINED pursuant to the requirements of Section 94-4.406 of the Ordinance Code until release by this Board.
CONTRA COSTA COUNTY Page 2 of 2 Printed on 7/2/2026
powered by Legistar™
City Council Staff Report
Item No. 5.10.
Date: July 14, 2026
To: San Ramon City Council
From: Brian Bornstein, Department Director
Andrew Stinnett, GIS Analyst
Subject: Resolution No. 2026-104 - Authorizing the Mayor to Execute an Agreement with Environmental Systems Research Institute (ESRI) for GIS Software Services for a Term Beginning July 1, 2026, and Ending June 30, 2029, in an Amount Not to Exceed $200,000
Executive Summary:
Environmental Systems Research Institute, Inc. (ESRI) has been the established vendor for Geographic Information Systems (GIS) with the City since 2013. The City has utilized ESRI’s desktop and server GIS software since that time to build out infrastructure required to support all aspects of city operations. The current contract expired on June 30, 2026. Due to the configuration of ESRI's product offerings which integrate relational database technology with desktop and web-enabled software, there are no comparable and costeffective alternatives. Staff recommends executing a three-year agreement with ESRI as the sole source provider of GIS software, effective July 1, 2026, through June 30, 2029. Staff anticipate that the execution of this Agreement will freeze price increases for the duration of the contract and position the City to maintain the level of service it has grown accustomed to for the next three years.
Recommendation:
The City Council’s role is to consider adopting this Resolution, authorizing the Mayor to execute an agreement with Environmental Systems Research Institute, Inc. (ESRI) for GIS software services for a term beginning July 1, 2026, and ending June 30, 2029, in an amount not to exceed $200,000.
Background:
ESRI has been the City of San Ramon's GIS software provider since 2013. When the original software agreement was signed, ESRI provided desktop and server software primarily used by the Engineering Department. Since 2013, GIS usage has spread from Engineering to other departments across the City, including Planning, Public Services, Police, and Parks & Community Services. The City GIS feeds data to other software essential for the City’s operation, such as Energov, EnCodePlus and Brightly. The agreement has been renewed on a yearly basis with small price increases each year.
The GIS acts as a repository for municipal spatial data. Data is sourced from many government agencies such as: Contra Costa County, East Bay Regional Park District, Dublin San Ramon Services District, City of Dublin and Central Contra Costa Sanitary District as well as data collected in the field by City staff. In addition to City staff, the GIS is also used by private organizations such as PG&E, cellular phone companies, cable providers and the City’s solid waste management company (Alameda County Industries) to provide services used by the residents of San Ramon. Behind all the computer information systems used by the City to make day-to-day government operations efficient is a GIS that integrates, analyzes and feeds data to them in real-time.
Discussion:
ESRI’s ArcGIS is widely considered the industry standard GIS platform for local government in the United States. An estimated 80%+ of US Cities, Counties, and Special Districts use ArcGIS in some form. Due to the configuration of ESRI's product, which integrates relational database technology with desktop and web-enabled software, there is no vendor offering similar solutions in a comprehensive package. Alternatively, staff could pursue a combination of other vendors’ software to approximate ESRI’s offerings, but the total software costs are likely to be much higher.
The proposed Agreement amount of $200,000 includes costs for the annual maintenance of desktop and server software, along with associated upgrades to keep pace with functionality and industry standard security practices. The execution of this Agreement will freeze price increases for the duration of the contract and position the City to maintain the level of service it has grown accustomed to for the next three years.
Fiscal Impact:
Funding for Year 1 of the proposed three-year agreement was approved through the City's FY 2026/27 Operating and Capital Improvement Program (CIP) previously adopted by the City Council. Funding has been appropriated from a combination of sources, including the General Fund and the GIS Fund, as appropriate and authorized, and no additional funds are being requested.
Funding for Years 2 and 3 of the proposed agreement will be included in future budget development processes until the contract has expired or all funds have been expended.
Alternative Option(s):
Should the City Council decline to approve the Resolution, it is likely that there will be standard annual price increases by ESRI in the coming years, and the annual GIS software expenses will increase.
Next Steps:
1. The City Attorney's Office will forward the Contract Agreement to ESRI for execution.
2. Upon receipt of the executed Agreement, the Engineering Division will continue to use the software and services provided by ESRI to maintain citywide operational continuity.
Attachment(s):
A. Resolution 2026-104
ATTACHMENT A
RESOLUTION NO. 2026-104
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SAN RAMON
AUTHORIZING THE MAYOR TO EXECUTE AN AGREEMENT WITH ENVIRONMENTAL SYSTEMS RESEARCH INSTITUTE, INC. (ESRI) FOR GIS SOFTWARE SERVICES FOR A TERM BEGINNING JULY 1, 2026, AND ENDING JUNE 30, 2029, IN AN AMOUNT NOT TO EXCEED $200,000
WHEREAS, Environmental Systems Research Institute, Inc. (ESRI) has been the established vendor providing Geographic Information Systems (GIS) software services to the City of San Ramon since 2013; and
WHEREAS, the City utilizes ESRI desktop and server software across multiple departments to maintain central data repositories and integrate critical real-time data with operational municipal software systems; and
WHEREAS, the current annual software agreement expired on June 30, 2026; and WHEREAS, there is no other single vendor capable of providing a similarly comprehensive package, thereby qualifying ESRI as a sole-source provider; and WHEREAS, executing a three-year agreement will effectively freeze standard software price increases for the duration of the contract, allowing the City to economically maintain its established level of service through June 30, 2029.
NOW, THEREFORE, BE IT RESOLVED, that the City Council of the City of San Ramon does hereby authorizes the Mayor to execute a three-year professional software agreement, in a form approved by the City Attorney, with ESRI for GIS Software Services for a term beginning July 1, 2026, and ending June 30, 2029, in an amount not to exceed $200,000.
PASSED, APPROVED, AND ADOPTED, at the meeting of July 14, 2026, by the following votes:
AYES:
NOES:
ABSENT:
ABSTAIN:
________________________________
Mark Armstrong, Mayor
ATTEST:
Joan Snashall, City Clerk
City Council Staff Report
Item No. 5.11.
Date: July 14, 2026
To: San Ramon City Council
From: Christina Franco, Deputy City Manager
Joan Snashall, City Clerk
Subject: Planning Commission Appointment
Executive Summary:
At the June 23, 2026, City Council meeting, the City Council directed staff to contact the designated Planning Commission waitlist candidate, Abhijit Banerjee, to determine whether he remained interested in serving on the Planning Commission. Staff contacted Mr. Banerjee, who confirmed his continued interest in serving.
In accordance with the City Council's direction, the appointment of Mr. Banerjee has been placed on the agenda for City Council consideration. If appointed, Mr. Banerjee will serve on the Planning Commission through the next regular recruitment cycle, with a term ending June 30, 2027.
Recommendation:
Staff recommends that the City Council appoint Abhijit Banerjee to the Planning Commission to fill the vacancy through the next regular recruitment cycle ending June 30, 2027.
Background:
The Planning Commission consists of five regular members serving staggered four-year terms. Recruitment for the Planning Commission is conducted every two years in oddnumbered years.
On August 14, 2025, the City Council conducted interviews for a Planning Commission vacancy and appointed Max Zhang to serve a term expiring June 30, 2029. At the same meeting, the City Council established a waitlist and designated Abhijit Banerjee as the waitlist candidate should a vacancy occur before the next regular Planning Commission recruitment in 2027.
On May 6, 2026, Commissioner Zhang resigned from the Planning Commission, creating a vacancy.
The vacancy was brought before the City Council for direction at the June 23, 2026, meeting. The City Council discussed the process for filling the vacancy and directed staff to contact the designated waitlist candidate to determine whether he remained interested in serving. The City Council further directed that, if the waitlist candidate confirmed his interest, staff should return with the appointment for City Council consideration at a subsequent meeting. If the candidate declined, the City Council directed staff to initiate a new recruitment process.
Staff contacted Mr. Banerjee following the meeting, and he confirmed that he remains interested in serving on the Planning Commission. Accordingly, this item has been brought forward for the City Council's consideration of his appointment to fill the vacancy through the next regular recruitment cycle ending June 30, 2027, consistent with the City Council's previous direction.
Fiscal Impact:
There is no fiscal impact associated with this item.
Alternative Option(s):
Direct staff to conduct a new recruitment process to solicit applications for the Planning Commission vacancy.
Next Steps:
The City Clerk's Office will complete the necessary administrative actions to finalize Mr.
Banerjee's appointment to the Planning Commission through June 30, 2027.
Attachment(s):
A. Application
From: [email protected]
To: Joan Snashall
Subject: Planning Commission Application 2025-07-31 04:10 PM(PST) Submission Notification Date: Thursday, July 31, 2025 4:10:46 PM
***| EXTERNAL EMAIL: Think before you click and do not open attachments unless you know they are safe. |***
Planning Commission Application 2025-07-31 04:10 PM(PST) was submitted by Guest on 7/31/2025 7:10:37 PM (GMT-08:00) US/Pacific
Name Value
fullname Abhijit Banerjee
cellphone
primaryphone cellprimary
firstname Abhijit
businessphone
middlename
homephone
lastname Banerjee
address1
email
address2 Enter Address Line 2
Gender male
city San Ramon
state CA
zip 94582
18years yes
policeacademy policeacademy
planacademy planacademy
gov101 gov101
none
residency 6 Years
experience
occupation Product & Engineering Leader
companyname Salesforce
position Product Leader
availability
Available Weekdays Evenings (and afternoons if needed) and Weekends to meet and discuss issues brought forth to Planning Commission for their inputs
My professional experience as a Product Leader provides a strong
ATTACHMENT A
edu-exp
foundation in strategic planning, data analysis, problem solving and effective stakeholder management - all skills essential for the Planning Commission. Beyond my career, I have actively sought to educate myself on local governance and planning by attending the City of San Ramon’s programs, including the Citizens Police Academy, Planning Academy, and San Ramon Government 101. This formal education has been supplemented by direct community leadership. As the President of my Homeowners Association (HOA), I have gained hands-on experience in community administration and the practical application of local regulations. My commitment to community service extends to various volunteer efforts, such as organizing events for National Night Out, teaching Hindi language at Chinmaya Mission, and participating in local park and beach cleanups. I am also a recognized proponent of renewable technology and have been commended by the "Save our Soil Foundation" for my commitment to zero green waste, which I believe could benefit our city's open spaces.
goodcandidate
My candidacy for the Planning Commission is rooted in a deep, longstanding appreciation for the City of San Ramon's unique character and a proven commitment to community service. Since my first professional interactions at Bishop Ranch in the late 1990s, I have been impressed by San Ramon’s thoughtful balance of economic growth and quality of life.
This led me to fulfill a dream of moving here in 2019, where I have since immersed myself in the community. My participation in the Citizens Police Academy, Planning Academy, and San Ramon Government 101 has provided me with a strong foundational knowledge of city governance.
This insight, combined with my professional experience as a Product Leader and my role as a Homeowners Association (HOA) President, gives me a unique perspective on both strategic, long-term planning and the practical, day-to-day needs of our residents. I am a dedicated community member who is eager to contribute my skills and passion to ensure San Ramon continues to thrive.
planning_zoning
My knowledge of planning and zoning is a blend of formal education and practical, hands-on experience. I have an expanded understanding of local city governance through my participation in the San Ramon Planning Academy and San Ramon Government 101. These programs provided me with a comprehensive overview of the city's master plan, zoning ordinances, and the processes by which they are administered. On a practical level, as the President of my Homeowners Association, I am directly involved in enforcing community standards and ensuring compliance with local regulations, which often involves interpreting and applying principles related to land use and community aesthetics. Prior to moving to San Ramon, I worked very closely with City of Fremont Planning Department, to design and build extension to my former home - giving me a first hand knowledge and understand of the various city and building codes. My experience also extends to a broader appreciation for infrastructure, traffic management, and the preservation of open spaces— all key components of effective planning and zoning.
My most important contribution as a member of the Planning Commission would be to bring a balanced, value-driven perspective that prioritizes
contribution
sustainable growth and community quality of life. I would be a vocal proponent for initiatives that align with my belief in responsible growth and environmental stewardship, such as promoting effective use of land and open spaces and bringing in ideas to have the least environmental footprint. My goal is to serve as a bridge between the city’s administrative vision and the concerns of its citizens, ensuring that new developments and policies not only support our city's economic vitality but also protect the small-town character, great schools, and community feel that draw people here. I would work tirelessly to ensure that our decisions are wellreasoned, transparent, and in the best long-term interest of all San Ramon residents.
growth
I have a very positive but measured attitude toward growth. I believe that thoughtful, well-managed growth is essential for a city's vibrancy and prosperity. San Ramon serves as a testament to this, as it has masterfully grown into a bustling corporate and residential hub without compromising its exceptional quality of life. In this context, I am keenly aware of the current housing shortage and the mandate of California's Regional Housing Needs Allocation (RHNA), which requires cities to comply with targeted housing numbers to avoid risking funding cuts. My priority is to support growth that is not just about expansion, but about enhancement—creating a more livable, sustainable, and inclusive city. I will be sensitive to this issue to ensure San Ramon can be more socio-economically inclusive and make housing more affordable, without compromising the growth and quality of life that our city is known for. I would approach each new planning decision with the mindset of building upon our existing strengths and ensuring that we continue to provide the unique combination of corporate opportunity, small-town charm, and community services that I was so impressed with 25 years ago and that still exists today.
To view this form submission online, please follow the link below:
https://www.sanramon.ca.gov/form/one.aspx?
objectId=20932787&contextId=15069077&returnto=submissions
City Council Staff Report
Item No. 9.1.
Date: July 14, 2026
To: San Ramon City Council
From: Martin Lysons, City Attorney
Brian Bornstein, Department Director
Subject: Resolution No. 2026-105 - Authorizing the Mayor to Approve an Amendment to the Southern Contra Costa Joint Exercise of Powers Agreement (SCC JEPA) Pertaining to Fees for Regional Traffic Mitigation Executive Summary:
The City of San Ramon (the “City”), Contra Costa County (the “County”), and the Town of Danville (the “Town”) are parties to the Joint Exercise of Powers Agreement pertaining to Southern Contra Costa Fees for Traffic Mitigation (the “SCC JEPA”). The SCC JEPA provides a funding mechanism to mitigate traffic impacts generated by development in the southern part of Contra Costa County, generally from Alamo south to the county line. The SCC JEPA includes a Regional Fee and a Sub-Regional Fee.The original purpose of the Regional Fee was to fund three projects: (1) Improvements to the I-680 ramps at Alcosta Boulevard; (2) the Auxiliary lane along I-680 from Diablo Road to Bollinger Canyon Road; and (3) Improvements to the I-680 ramps at Stone Valley Road. With the first two of these projects now complete, staff from all three parties to the SCC JEPA have met and determined that it is an appropriate time to discontinue the SCC Regional Fee. Remaining SCC Regional fees currently retained by the County will be directed toward the completion of the I-680/Stone Valley Road project, while remaining SCC Regional fees retained by the City and Town, if any, will be contributed to the Contra Costa Transportation's "Innovate 680" project list.
These new allocations will require an amendment to the SCC JEPA, including a change to the SCC Regional Fee project list.
The County Board of Supervisors and the Danville Town Council have each approved this amendment to the SCC JEPA.
Recommendation:
Adopt Resolution 2026-105 (Attachment A) approving an amendment to the Joint Exercise of Powers Agreement pertaining to Southern Contra Costa fees for Traffic Mitigation (SCC JEPA).
Background:
In 1996, Contra Costa County (the “County”), the City of San Ramon (the “City”) and the Town of Danville (the “Town”) entered into the Joint Exercise of Powers Agreement pertaining to Southern Contra Costa Fees for Traffic Mitigation (the “SCC JEPA” or Agreement,” Attachment B). The SCC JEPA provides a mechanism for the parties to mitigate collectively the impacts of additional traffic generated by development in the southern part of Contra Costa County, generally from Alamo south to the county line. The SCC JEPA was structured to address the findings of the August 1996 Development Program Report for the Southern Contra Costa Fee Areas (the “DPR,” Attachment C).
The SCC JEPA includes two fees that all three jurisdictions participate in: the SCC Regional Fee and the SCC Sub-Regional Fee. The SCC Regional fee is dedicated to area freeway improvement projects, benefiting the entire SCC area. The SCC JEPA included an initial list of three projects to be funded in part by the SCC Regional Fee:
(1) Improvements to the I-680 ramps at Alcosta Boulevard; (2) the Auxillary lane along I-680 from Diablo Road to Bollinger Canyon Road; and (3) Improvements to the I-680 ramps at Stone Valley Road.
The DPR anticipated that changes in circumstances would require periodic review and updates to the SCC fees to address changing impacts and mitigations. Because of this, the Agreement provides that the parties shall review and may update the list of projects. Now, with the first two SCC Regional projects listed above complete, the parties to the SCC JEPA have met and agreed that it is appropriate for the parties to discontinue collection of the SCC Regional Fee.
Once the SCC Regional Fee is discontinued, the County will use its collected SCC Regional Fee funds to complete the last remaining SCC Regional project (the I-680/Stone Valley Road improvements). The City and Town will contribute any excess funds toward freeway improvements to Interstate 680 planned for by the Contra Costa Transportation Authority (the “CCTA”). The improvements identified by CCTA are collectively described as “Innovate 680.” The regional impact of those improvements and their relation to planning documents for all three entities are addressed in a report prepared by Fehr & Peers, dated May 19, 2026, which is included herewith as Attachment D. Allocating the remaining SCC Regional funds in this manner will require an amendment to the SCC JEPA and its regional project list.
There is no change to the SCC Sub-Regional fees at this time. There are still outstanding San Ramon projects on the subregional list that have not been fully funded and completed, including the Crow Canyon Widening Phase 2 from St. George to Dougherty Road.
Fiscal Impact:
None. The SCC Regional fees are “pass-through” fees. They are collected by the City and passed on to the appropriate agency (in this case, CCTA), aggregated with funds from other sources, and used for projects of regional benefit.
Alternative Option(s):
If the Council elects not to execute this Amendment, the City, Town, and County will continue to collect SCC JEPA regional fee without unfunded projects on its list, in violation of AB 1600, which requires a nexus for any development fee collected.
Next Steps:
The City will transfer its SCC Regional Fee balance, if any, to contribute to the funding of Innovate 680 in accordance with the SCC JEPA Amendment and discontinue collection of the SCC Regional Fee.
Attachment(s):
A. Resolution No. 2026-105
B. SCC JEPA Agreement
C. Development Program Report for the SCC Area
D. Fehr & Peers Summary of SCC Regional Fees Program Memo
ATTACHMENT A
RESOLUTION NO. 2026-105
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF SAN RAMON
AUTHORIZING THE MAYOR TO APPROVE AN AMENDMENT TO THE SOUTHERN
CONTRA COSTA JOINT EXERCISE OF POWERS AGREEMENT (SCC JEPA) PERTAINING
TO FEES FOR REGIONAL TRAFFIC MITIGATION
WHEREAS, in 1996, Contra Costa County (the “County”), the City of San Ramon (the City”) and the Town of Danville (the “Town”) entered into the Joint Exercise of Powers Agreement pertaining to Southern Contra Costa Fees for Traffic Mitigation (the “SCC JEPA” or “Agreement”); and
WHEREAS, the SCC JEPA provides a mechanism to collectively mitigate the impacts of additional traffic generated by development in the southern part of Contra Costa County, generally from Alamo south to the county line; and
WHEREAS, the SCC JEPA includes the SCC Regional fee, which helps fund area freeway improvement projects, benefitting the entire SCC area. The original JEPA includes three regional freeway projects, only one of which remains uncompleted (the Stone Valley I-680 ramp project); and
WHEREAS, the SCC JEPA provides authority for the three parties to annually review and update the list of projects to be funded by the SCC Fees; and WHEREAS, the three parties have met and conferred and determined that it would be appropriate to add a fourth project to the SCC Regional list, specifically the Innovate 680 project being funded in part by the Contra Costa Transportation Authority (CCTA). A technical memo prepared by the firm of Fehr & Peers explains the connection between the Innovate 680 project and the General Plans of all three jurisdictions; and WHEREAS, the three parties agree that once the Amended SCC JEPA is approved, the Town and City shall transfer their fund balances of SCC Regional fees, if any, to CCTA for the Innovate 680 project, the County will place its current fund balance into a trust account to be spent on the I-680/ Stone Valley Road project and all three parties shall stop collection of the SCC Regional fee.
NOW, THEREFORE, BE IT RESOLVED, that the City Council of the City of San Ramon does hereby authorize the Mayor to execute the Amendment to the Joint Exercise of Powers Agreement Pertaining to Southern Contra Costa Fees for Traffic Mitigation (SCC JEPA).
PASSED, APPROVED, AND ADOPTED, at the meeting of July 14, 2026, by the following votes:
AYES:
Resolution No. 2026-105
NOES:
ABSENT:
ABSTAIN:
________________________________
Mark Armstrong, Mayor
ATTEST:
Joan Snashall, City Clerk
ATTACHMENT B
ATTACHMENT C
ATTACHMENT D
City Council Staff Report
Item No. 9.2.
Date: July 14, 2026
To: San Ramon City Council
From: Jennifer Wakeman, Department Director
Subject: Introduction to the Long-Term Financial Plan
Executive Summary:
The City's financial resiliency framework includes the establishment of a model for forecasting. Using financial tools to inform Council’s decision-making is part of the City’s effort to continuously work toward fiscal sustainability. The City’s new forecasting model was developed by Russ Branson Consulting and looks out 10 years to align with the expiration of Measure N and includes a baseline reflecting financial certainties known by the City today. Alternative forecasts may be developed with this model so that various scenarios may be tested and/or planned for.
Recommendation:
Council's role is to receive the information presented, then discuss the material and provide feedback on the recommendations outlined.
Background:
A long-term financial plan is a strategic document that helps the City plan its finances over several years to ensure that services can be sustainably provided, infrastructure maintained, and financial obligations met. It is also used to prepare for risks and uncertainties, which is why San Ramon's model has been designed to look out 10 years to FY35 when Measure N is set to expire. This add-on sales tax measure was passed in order to continue the current level of City services, subsidizing general operations in FY27 by about $14m.
Due to the important informational role of this model, the baseline forecast factors in only current and future financial impacts that are known in terms of timing and amount. This allows for reasonable projections upon which Council can rely. Some examples are historical growth rates in the largest revenue categories and specific details from employee agreements. Economic and financial impacts that are less certain in nature can be reflected in the model with the use of alternative forecasts and allow the City to “test” different
scenarios. Items that could be included here would be a potential recession, changes to CalPERS pension policies, or the receipt of development-related fees.
The model currently includes actual revenue and expenditure figures through FY25 and the FY26 projected actual and FY27 budget figures from the FY27 adopted budget. The resulting baseline forecast confirms the City’s financial situation; the City would have an operating deficit in the current and outlying years without Measure N. Further, it visibly shows the significant shortfalls the City will likely experience when Measure N expires in FY35.
Fiscal Impact:
There is no direct fiscal impact from the recommended action, however, this forecasting tool is anticipated to guide Council’s future financial discussions and decisions.
Alternative Option(s):
Provide direction for revised or different recommended next steps.
Next Steps:
With acceptance of this new long-term financial planning model, staff will receive training on the model for maintenance and updating and will begin work on the recommendations provided.
Attachment(s):
None