EXHIBIT 1
SANTA ANA PROJECT 22-1802 & 22-1382
Ip I CITY COUNCIL NEWHOPE LIBARY MODERNIZATION&
,. WA f AGENDA DATE: DELHI CENTER LIBRARY BRANCH PROJECT !1---- .... �PTEMBER 17, 20 4 LOCATION MAP le Li&IICY
SANTA ANA
<AU
PAGE 1 OF 2
EXHIBIT 1
PWA
SANTA ANA
PUBLIC WORKS AGENCY
EXHIBIT 2
PAGE 2 OF 2
LOCATION MAP
DELHI CENTER LIBRARY BRANCH PROJECT
NEWHOPE LIBARY MODERNIZATION&
PROJECT 22-1802 & 22-1382
SEPTEMBER 17, 2024
AGENDA DATE:
CITY COUNCIL
M
OBILE
M
OBILE
M
OBILE
MOBILE MOBILE
U.C.
Refr.
NEW METAL STUD WALL PER SHEET A61.1
EXISTING METAL STUD WALL
EXISTING CONCRETE WALL
NOT IN SCOPE
2-HR RATED FIRE BARRIER
1-HR RATED FIRE PARTITION
WALL TYPE ANNOTATIONS, SEE SHEET
A61.1 FOR DETAILS
1 101 NUMBER INDICATES DOOR PER SCHEDULE,
REFER TO SHEET A52.1
NUMBER INDICATED WINDOW PER SCHEDULE,
REFER TO SHEET A53.1
FIRE EXTINGUISHER CABINET PER DET. XX/XX
FLOOR PLAN GENERAL NOTES:
1. ALL DIMENSIONS ARE TO CENTERLINE OF THE GRID LINES AND/OR TO THE FACE OF STUDS, U.N.O.
2. UNLESS NOTED OTHERWISE, ALL WALLS ARE FULL HEIGHT.
3. REFER TO SHEET GEN-4 FOR TYPICAL ACCESSIBILTY REQUIREMENTS AND DIMENSIONS.
4. REFER TO ENLARGED PLANS FOR DIMENSIONS AND CALLOUTS NOT SHOWN HERE.
1i
60" MIN. ACCESSIBLE WHEELCHAIR
CLEAR TURNING SPACE
CLR. 60" MIN.
30"X48" MIN. ACCESSIBLE WHEELCHAIR
CLEAR FLOOR SPACE
30"X48"
CLR.
1-HR RATED FIRE BARRIER
504 SF
CHILDRENS
AREA
5 293 SF
TEEN
AREA
4 1080 SF
GENERAL
STACKS
3 57 SF
RESTROOM
2 275 SF
OFFICE
1 124000.D
E132
124000.M 124000.M 124000.M 124000.M
205 SF
READING
AREA
7 5' - 0"
1' - 0" 1' - 0" 1' - 0"
1 A22.1
2 A22.1
2' - 7"
107100.B
107100.B
064100.B
064100.B
064100.B
12' - 1"
12' - 1"
12' - 1"
124000.P
124000.P
124000.S
124000.T
124000.U
124000.V
30X48 CLEAR
3' - 9"
064100.I
124000.O
MOBILE
MOBILE
MOBILE
MOBILE
124000.O
064100.K
4' - 9"
THIS DOCUMENT CONTAINS INFORMATION PROPRIETARY TO SVA ARCHITECTS INC. AND IS FURNISHED IN CONFIDENCE FOR THE LIMITED PURPOSE OF EVALUATION, BIDDING OR REVIEW. THIS DOCUMENT OR ITS CONTENTS MAY
NOT BE USED FOR ANY OTHER PURPOSE AND MAY NOT BE REPRODUCED OR
DISCLOSED TO OTHERS WITHOUT THE PRIOR WRITTEN CONSENT OF SVA ARCHITECTS INC. ALL RIGHTS RESERVED, © COPYRIGHT 2018.
SCALE:
REVISIONS:
OWNER:
PROJECT NAME:
CLIENT ADDRESS:
6 HUTTON CENTRE DR, SUITE 1150 SANTA ANA, CA 92707
T 949.809.3380 WWW.SVA-ARC HITECTS.COM DATE ISSUED:
PROJECT NO:
1/4" = 1'-0"
Issue Date
A11.6
IMPROVEMENTS -
FURNITURE
PLAN
#2022-40198
CITY OF SANTA ANA
DELHI COMMUNITY CENTER
RENOVATION
505 E Central Ave, Unit B, Santa Ana, CA 92707
FLOOR PLAN LEGEND 1/4" = 1' -0" 1PROPOSED FURNITURE PLAN 064100.B WALL-MOUNTED COUNTERTOP, SEE DET. 03/A63.3
064100.I ONE SIDED LIBRARY SHELVING, OFCI
064100.K WALL-MOUNTED COUNTERTOP, SEE DET. 05/A63.3
107100.B (N) FLOOR MOUNTED DESIGNER CLEAR SECURITY G ATE LIB-180 RFID SCANNER, SEE SPECS FOR TYPE/SIZE, OFOI
124000.D 4 TOP CIRCULAR TABLE AND CHAIRS, TYP., OFOI
124000.M NEW RIVELI MODULAR FOLDING SHELVING SYSTEM, OFCI 124000.O MOBILE BOOK CARTS, OFOI
124000.P CHILDERENS FURNITURE, TYP., OFOI
124000.S 8 TOP WORKING TABLE WITH INDIVIDUAL SEAT DI VIDERS,
FLUSH MOUNTED POWER PROVIDED, OFOI
124000.T WORKSTATIONS, OFOI
124000.U MOBILE BOOK CARTS, OFOI
124000.V BOOK DROPOFF COLLECTION BIN, OFOI
E132 INKJET PRINTER, OFOI
KEYNOTES
DESCRIPTION DATE
N