Project InformationPlot Plan
c COPYRIGHT; Oldham Architects expresslyreserves all rights to these plans by commoncopyright privileges. These plans may not bereproduced, changed, or copied in any manneror turned over to a third party without theexpressed written consent of Ryan E. Oldham. architectsoldham architects680 Langsdorf Drive, Suite 202Bfullerton, california 92831714.482.8296 | oldham-architects.com oldham
ISSUE:CHECK:DRAWN:PROJECT No.:
2221 Heliotrope2221 Heliotrope Drive, Santa Ana, CA 92706

07.12.24 PLANNING SUBMITTALRODM23081
2221 HELIOTROPE ADU NEW GAZEBO PAVILION
PROPOSEDPAVILLION205 SFSANTA CLARA AVENUE
HELIOTROPE DRIVESite Plan 1Scale: 116" = 1'-0"
(E) 1 STORYADU - NOT IN SCOPE
(E) 2 STORYSINGLE FAMILYRESIDENCE -NOT IN SCOPE
(E) 1 STORYGARDEN ROOM -NOT IN SCOPE
Project Data
Vicinity Map
A0.0
SCOPE OF WORK:INSTALLATION OF A PRE-FABRICATED, 205 SFFREESTANDING, UNENCLOSED, NON-HABITABLE , GARDEN PAVILIONIN BACKYARD OF PROPERTY. NO CHANGE TO (E) HOME OROTHER (E) STRUCTURES ON THE PROPERTY.APPLICANTS / OWNERS:DR.CHAN KIEU & DR. QUYNH KIEU2221 N. HELIOTROPE DR., SANTA ANA, CA 92706(714) 724-0855 [email protected] ADDRESS: 2221 N. HELIOTROPE DR.,SANTA ANA, CA 92706ASSESSORS PARCEL NUMBERS: 002-081-45 & 002-081-46LEGAL DESCRIPTION: TR 1035 LOT 17, LOT 18 AND LOT 19GENERAL PLAN LAND USE DESIGNATION: LR 7.0ZONING DISTRICT: R1TOTAL LOT SIZE: 39,547 SF (0.908 ACRES)HISTORIC PROPERTY: YESHISTORIC DISTRICT: NOTYPE OF CONSTRUCTION: V-B (NON-SPRINKLED)PROPOSED NUMBER OF STORIES: 1PROPOSED STRUCTURE HEIGHT: 21' - 4"OCCUPANCY OF PROPOSED BUILDING: U (ACCESSORY STRUCTURE)OCCUPANCY OF EXISTING STRUCTURES: R-3PROPOSED EXTERIOR WALL AND ROOF MATERIALS:STRUCTURE:WOODROOF:CLAY TILEEXISTING BUILDINGS EXTERIOR WALL AND ROOF MATERIALS:WALL:STUCCOROOF:BUILT UP ROLL ROOFINGGOVERNING CODES:2022 CALIFORNIA RESIDENTIAL CODE (CRC)2022 CALIFORNIA MECHANICAL CODE (CMC)2022 CALIFORNIA ELECTRICAL CODE (CEC)2022 CALIFORNIA PLUMBING CODE (CPC)2022 CALIFORNIA GREEN BUILDING CODE (CALGREEN)AHJ AND LOCAL CODES AND NFPA A2.0Floor PlanElevations
c COPYRIGHT; Oldham Architects expresslyreserves all rights to these plans by commoncopyright privileges. These plans may not bereproduced, changed, or copied in any manneror turned over to a third party without theexpressed written consent of Ryan E. Oldham. architectsoldham architects680 Langsdorf Drive, Suite 202Bfullerton, california 92831714.482.8296 | oldham-architects.com oldham
ISSUE:CHECK:DRAWN:PROJECT No.:
2221 Heliotrope2221 Heliotrope Drive, Santa Ana, CA 92706

07.12.24 PLANNING SUBMITTALRODM23081
2221 HELIOTROPE ADU NEW GAZEBO PAVILION
Ground Floor Plan1Scale: 316" = 1'-0"
Main Floor Plan2Scale: 316" = 1'-0"
Roof Floor Plan3Scale: 316" = 1'-0"
AA
AA
AA
4Scale: 316" = 1'-0"
5Scale: 316" = 1'-0"
6Scale:18" = 1'-0"
South ElevationWest Elevation7Scale: 316" = 1'-0"10Scale: 316" = 1'-0"Section AA North ElevationEast Elevation8Scale: 316" = 1'-0"
Composite Elevation