01-GROUND FLOOR
0' - 0"
02 - SECOND FLOOR
16' - 0"
07-ROOF
67' - 3 5/8"
08-T.O. PARAPET
73' - 4 5/8"
03-THIRD FLOOR
26' - 1 5/8"
04 - FOURTH FLOOR
36' - 4 3/4"
05 - FIFTH FLOOR
46' - 7 7/8"
06 - SIXTH FLOOR
57' - 1 1/8"
01.1-GROUND FLOOR 2
0' - 6"
MAX HT PER CBC
85' - 0"
PENTHOUSE PLATE
77' - 4 5/8"
01.2-GROUND FLOOR 3
2' - 0"
rrmdesign.com | (805) 543-1794
CONSULTANT
AGENCY
NO. REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
NOT FO
R
CO
NS
TRUCTIO
N
NOT FO
R
CO
NS
TRUCTIO
N
RRM DESIGN GROUP COPYRIGHT 2024
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIGNS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FOR PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROUP'S RIGHTS.
Autodesk Docs://2121_SM Downtown REdev/2121-04-RS23_Alvin Newton Mixed-Use Building_V22.rvt 6/6/2024 2:35:48 PM
SOUTH ELEVATION
ALVIN NEWTON MIXED-USE
EAST MAIN ST & SOUTH BROADWAY,
SANTA MARIA, CA 93454
2121-04-RS23
A-1
MAY 30, 2024
DJC
JM
SCALE: 1/8" = 1'-0"A-1
SOUTH ELEVATION-DESIGN DEVELOPMENT1
SCALE: 1/8" = 1'-0"A-1
SOUTH ELEVATION-ENTITLEMENTS2
WINDOW
AWNINGS
STANDARDIZED FOR
DURABILITY AND
CONSTRUCTABILITY
CONCERNS
WINDOWS RESIZED,
ADDED, OR
REMOVED PER UNIT
LAYOUT
DEVELOPMENT
Attachment C
01 -GROUND FLOOR
0' - 0"
02 - SECOND FLOOR
16' - 0"
07 -ROOF
67' - 3 5/8"
08 -T.O. PARAPET
73' - 4 5/8"
03 -THIRD FLOOR
26' - 1 5/8"
04 - FOURTH FLOOR
36' - 4 3/4"
05 - FIFTH FLOOR
46' - 7 7/8"
06 - SIXTH FLOOR
57' - 1 1/8"
MAX HT PER CBC
85' - 0"
PENTHOUSE PLATE
77' - 4 5/8"
rrmdesign.com | (805) 543-1794
CONSULTANT
AGENCY
NO. REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
NOT FO
R
CO
NS
TRUCTIO
N
NOT FO
R
CO
NS
TRUCTIO
N
RRM DESIGN GROUP COPYRIGHT 2024
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIG NS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPER TY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSE D TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER T HAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVEL OPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDE NCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FO R PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROU P'S RIGHTS.
Autodesk Docs://2121_SM Downtown REdev/2121-04-RS23_Alvin Newton Mixed-Use Building_V22.rvt 6/6/2024 2:35:57 PM
NORTH ELEVATION
ALVIN NEWTON MIXED-USE
EAST MAIN ST & SOUTH BROADWAY,
SANTA MARIA, CA 93454
2121-04-RS23
A-2
MAY 30, 2024
DJC
JM
SCALE: 1/8" = 1'-0" A-2
NORTH ELEVATION-DESIGN DEVELOPMENT 1
SCALE: 1/8" = 1'-0" A-2
NORTH ELEVATION-ENTITLEMENTS2
WINDOWS RESIZED,
ADDED, OR
REMOVED PER UNIT
LAYOUT
DEVELOPMENT
RECESSES
INCORPORATED
FOR UNIT
BALCONIES
BALCONY RAILING
INCORPORATED
FOR UNIT
BALCONIES
MASSING PUSHED
BACK DUE TO TESLA
CHARGING
STATION CONFLICT
TESLA CHARGING
STATION LOCATION
01 -GROUND FLOOR
0' - 0"
02 - SECOND FLOOR
16' - 0"
07 -ROOF
67' - 3 5/8"
08 -T.O. PARAPET
73' - 4 5/8"
03 -THIRD FLOOR
26' - 1 5/8"
04 - FOURTH FLOOR
36' - 4 3/4"
05 - FIFTH FLOOR
46' - 7 7/8"
06 - SIXTH FLOOR
57' - 1 1/8"
MAX HT PER CBC
85' - 0"
PENTHOUSE PLATE
77' - 4 5/8"
01 -GROUND FLOOR
0' - 0"
02 - SECOND FLOOR
16' - 0"
07 -ROOF
67' - 3 5/8"
08 -T.O. PARAPET
73' - 4 5/8"
03 -THIRD FLOOR
26' - 1 5/8"
04 - FOURTH FLOOR
36' - 4 3/4"
05 - FIFTH FLOOR
46' - 7 7/8"
06 - SIXTH FLOOR
57' - 1 1/8"
MAX HT PER CBC
85' - 0"
PENTHOUSE PLATE
77' - 4 5/8"
rrmdesign.com | (805) 543-1794
CONSULTANT
AGENCY
NO. REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
NOT FO
R
CO
NS
TRUCTIO
N
NOT FO
R
CO
NS
TRUCTIO
N
RRM DESIGN GROUP COPYRIGHT 2024
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIG NS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPER TY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSE D TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER T HAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVEL OPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDE NCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FO R PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROU P'S RIGHTS.
Autodesk Docs://2121_SM Downtown REdev/2121-04-RS23_Alvin Newton Mixed-Use Building_V22.rvt 6/6/2024 2:36:11 PM
WEST AND EAST ELEVATION
ALVIN NEWTON MIXED-USE
EAST MAIN ST & SOUTH BROADWAY,
SANTA MARIA, CA 93454
2121-04-RS23
A-3
MAY 30, 2024
DJC
JM
SCALE: 1/8" = 1'-0" A-3
WEST ELEVATION-DESIGN DEVELOPMENT 1
SCALE: 1/8" = 1'-0" A-3
WEST ELEVATION-ENTITLEMENTS2
SCALE: 1/8" = 1'-0" A-3
EAST ELEVATION-DESIGN DEVELOPMENT 3
SCALE: 1/8" = 1'-0" A-3
EAST ELEVATION-ENTITLEMENTS4
MASSING PUSHED
BACK DUE TO TESLA
CHARGING
STATION CONFLICT
TESLA CHARGING
STATION LOCATION
OPENING AMOUNT
REDUCED FOR
CODE DUE TO
PROXIMITY TO
PROPERTY LINE
NEW OPENINGS
DUE TO MASSING
BEING PUSHED
BACK TO AVOID
CONFLICT WITH
TESLA CHARGING
STATION
WINDOWS RESIZED,
ADDED, OR
REMOVED PER UNIT
LAYOUT
DEVELOPMENT
WINDOWS RESIZED,
ADDED, OR
REMOVED PER UNIT
LAYOUT
DEVELOPMENT
rrmdesign.com | (805) 543-1794
CONSULTANT
AGENCY
NO. REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
NOT FO
R
CO
NS
TRUCTIO
N
NOT FO
R
CO
NS
TRUCTIO
N
RRM DESIGN GROUP COPYRIGHT 2024
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIG NS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPER TY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSE D TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER T HAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVEL OPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDE NCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FO R PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROU P'S RIGHTS.
Autodesk Docs://2121_SM Downtown REdev/2121-04-RS23_Alvin Newton Mixed-Use Building_V22.rvt 6/6/2024 2:36:18 PM
TYPICAL 2ND THROUGH 6TH
FLOOR
ALVIN NEWTON MIXED-USE
EAST MAIN ST & SOUTH BROADWAY,
SANTA MARIA, CA 93454
2121-04-RS23
A-4
MAY 30, 2024
DJC
JM
SCALE: 1/8" = 1'-0" 1
TYPICAL 2ND THROUGH 6TH FLOOR
PLAN-DESIGN DEVELOPMENT
THIS MASSING HAS
BEEN PUSHED BACK
TO AVOID
CONFLICT WITH
TESLA CHARGING
STATION
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
DS
OPEN ROOF
DECK BELOW
5" / 1'-0"
5" / 1'-0"
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
5" / 1'-0" 5" / 1'-0"
5" / 1'-0"
5" / 1'-0"
6" / 1'-0"
6" / 1'-0"
5" / 1'-0"
5" / 1'-0"
5" / 1'-0"
5" / 1'-0"
6" / 1'-0"
5" / 1'-0"
5" / 1'-0"
1/2" / 1'-0" 1/2" / 1'-0"
1/2" / 1'-0" 1/2" / 1'-0"
3 1/2" / 1'-0"
6" / 1'-0"
1/2" / 1'-0" 1/2" / 1'-0"
1/2" / 1'-0" 1/2" / 1'-0"
1/2" / 1'-0" 1/2" / 1'-0"
1/2" / 1'-0" 1/2" / 1'-0"
1/2" / 1'-0"
1/2" / 1'-0"
5" / 1'-0" 5" / 1'-0"
5" / 1'-0" 5" / 1'-0"
5" / 1'-0"
5" / 1'-0" 5" / 1'-0"
5" / 1'-0"
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
6" / 1'-0"
rrmdesign.com | (805) 543-1794
CONSULTANT
AGENCY
NO. REVISION DATE
PROJECT MANAGER
DRAWN BY CHECKED BY
DATE
PROJECT NUMBER
SHEET
NOT FO
R
CO
NS
TRUCTIO
N
NOT FO
R
CO
NS
TRUCTIO
N
RRM DESIGN GROUP COPYRIGHT 2024
RRM IS A CALIFORNIA CORPORATION
THE INCLUDED DRAWINGS, SPECIFICATIONS, IDEAS, DESIG NS AND ARRANGEMENTS
REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPER TY OF RRM DESIGN
GROUP AND NO PART THEREOF SHALL BE COPIED, DISCLOSE D TO OTHERS OR
USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER T HAN THE SPECIFIED
PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVEL OPED WITHOUT THE WRITTEN CONSENT OF RRM DESIGN GROUP. VISUAL CONTACT WITH THESE DRAWINGS
OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDE NCE OF ACCEPTANCE OF THESE RESTRICTIONS. SUBMITTAL OF THESE DOCUMENTS FO R PUBLIC AGENCY REVIEW SHALL NOT BE CONSIDERED A WAIVER OF RRM DESIGN GROU P'S RIGHTS.
Autodesk Docs://2121_SM Downtown REdev/2121-04-RS23_Alvin Newton Mixed-Use Building_V22.rvt 6/6/2024 2:36:20 PM
ROOF PLAN
ALVIN NEWTON MIXED-USE
EAST MAIN ST & SOUTH BROADWAY,
SANTA MARIA, CA 93454
2121-04-RS23
A-5
MAY 30, 2024
DJC
JM
SCALE: 1/8" = 1'-0" A-1 A-5
ROOF PLAN-ENTITLEMENTS2
SCALE: 1/8" = 1'-0" A-1 A-5
ROOF PLAN-DESIGN DEVELOPMENT 1