17 Attachment A
General Plan & Municipal Code Compliance Worksheet

ATTACHMENT A

GENERAL PLAN AND MUNICIPAL CODE COMPLIANCE WORKSHEET
Project Location and Permit Processing Time Limits
Project Address: 1029 26th Street
Application Filing Date: April 21, 2026
CEQA Deadline: DATE: July 15 with extension
PSA Deadline: DATE: July 20, 2026
Total Process Review
Time (Days):
71 days to July 1, 2026
General Plan and Municipal Code Compliance Worksheet

CATEGORY LAND
USE

ELEMENT

MUNICIPAL CODE PROJECT
Permitted Use Residential Childcare & Early Education
Facility Conditionally
Permitted Use in R1 zone
SMMC Table 9.07.020
CUP application
26ENT-0086
requested
Minimum Parcel Size --- 7,500 SF
SMMC Table 9.11.030
8,001 SF
Parking Access Alley
access is
encourage
d when
alley
exists.

Alley access is required when
alleys exist, with exceptions
per Sec. 9.28.120(B).
1 existing compliant
driveway space
accessed from 26th
Street
Parking location
standards
N/A 2 parking spaces restricted
use of front yard setback
1 space located in
driveway
Bicycle Parking N/A • Short term 1.5 spaces
per 20 children
40 children capacity=
3 short-term bike parking
spaces
• Long term bike
parking not required
4 short term bike
parking spaces

Attachment A
General Plan & Municipal Code Compliance Worksheet

18 for projects less than
2,500 SF
SMMC9.28.140
Early Education
Facility Parking
N/A 1 space/ 500 SF
SMMC 9.08.060
House 2,426 SF/ 500 SF = 5
spaces
No parking required
per State Law AB
2097.as site is within ½
mile of transit
Child Care Outdoor
Areas
NA CA State Law 75 SF per child
Staggered time outside for
children permitted
2,529 rear yard + 847=
3,376 SF front yard
outdoor play area
provides sufficient
outdoor play area
Trash Area N/A Trash enclosure with
minimum 5'- 8' solid wall and
gate is required
Shall comply with
standards provided by
Resource, Recovery,
Recycling (RRR)
Historic Resources
Inventory
N/A Existing structure is
more than 40 years old
and not a designated
landmark or listed on
the HRI nor
Standards for Specific Uses and Activities
SMMC 9.31.120, Child Care and Early Education Facilities Fence Walls N/A Allowed 4’ front fence/ 6’-8’
rear fence with controlled
entries
Complies: Existing 3.5’
front fence remains/ a
4’-0” hedge added/ 6’
rear fence with
controlled entries
Outdoor play area(s)
required by the State
for children 2 years
or older
N/A The State requires specific
indoor/outdoor play area SF
per child
Complies: 3,376 front
and rear yards SF
combined
Organized Outdoor
Activities-Hours in
residential zone
N/A 8 am-8 pm weekdays, 9 am-8
pm weekends;
Complies: 9:15 am-5:00 pm M-F
Passenger Loading N/A Mobility reviews the Parking
and Loading Operations Plan
SMMC 9.28.080.(C); one
street loading space at curb
frontage , one driveway
loading space
Complies: Mobility
approved the Parking
and Loading
Operations Plan June
30, 2026

Attachment A
General Plan & Municipal Code Compliance Worksheet

19 State and Other
Licensing
N/A Number of Children;
outdoor/indoor play area SF
/children to teacher ratio
Will Comply: State
License upgraded to
Childhood and Early
Education Facility;
local Ordinance will
require installation of a
sprinkler system
Neighborhood
Liaison
N/A On-site contact to address
neighborhood concerns
Director: Cassidy
Boesch