PROJECT
10/31/2025 10:02:01 AM
A22-2164

SANTEE, CA
6TH PLANNING
SUBMITTAL10.31.25
A0

TITLE SHEET

PALISADE SANTEE COMMERCE CENTER

PALISADE SANTEE COMMERCE CENTER
10990 WOODSIDE AVE N.

SANTEE, CA 92071

12.10.2025

12.11.2025

FH FH FH FH FH
FH
FH
FH
FH
FH
FH
FH
FH
FH
FH

LANDSCAPE AREA

CONCRETE PAVING WHEN OCCURS
@ PARKING AREAS, DRIVE AISLES,
& OR TRUCK COURT. SEE CIVIL

DRAWINGS FOR PAVING SECTIONS
FIRE HYDRANT. PROVIDE PIPE

BOLLARD PROTECTION POSTS AS

REQUIRED BY THE FIRE
AUTHORITY. SEE 3/AD1.1

LIGHT POLE
INDICATES AN ACCESSIBLE ROUTE.

MUST COMPLY w/ SITE PLAN
GENERAL NOTE #6

PROPERTY LINE

PROPOSED OFFICE

DOCK HIGH TRUCK DOOR

GRADE LEVEL TRUCK DOOR
# PARKING STALL COUNT TOTAL

FIRE LANE PER DEPARTMENT

REQUIREMENT
NORTH

PROJECT

LOCATION

N WOODSIDE AVE

WHEATLANDS AVE WHEATLANDS CT

1. THE SITE PLAN SHALL MEET ALL ENGINEERING & NPDES
REQUIREMENTS.

2. GENERAL CONTRACTOR TO REVIEW THE SOILS REPORT

AND ALL AMMENDMENTS LISTED ON THE TITLE SHEET
AND FOLLOW ALL RECOMMENDATIONS.

3. U.O.N., ALL DIMENSIONS TO CONCRETE WALLS AND

CURBS ARE EITHER TO THE CENTER (SHOWN WITH A
CENTERLINE) OR FACE OF THE WALL OR CURB. ALL

DIMESIONS TO FRAMED WALLS ARE EITHER TO THE

CENTER LINE OF THE WALL FRAMING (SHOWN WITH A
CENTERLINE) OR THE FACE OF THE WALL FINISH.

4. REFER TO CIVIL, AND MEP PLANS TO CONFIRM UTILITY

INFORMATION SHOWN ON THE ARCHITECT'S SITE PLAN
AND FOR ADDITIONAL UTILITY INFORMATION. GENERAL

CONTRACTOR TO COORDINATE ALL POINTS OF
CONNECTION.

5. REFER TO CIVIL DRAWINGS FOR ALL FINISHED GRADES
AND SLOPES. ALL FINISHED GRADES TO PROVIDE
POSITIVE DRAINAGE AWAY FROM THE BUILDING.

GENERAL CONTRACTOR TO FIELD VERIFY.

6. ALL ACCESSIBLE ROUTES INDENTIFIED ON THE SITE PLAN
DRAWINGS SHALL CONFORM TO THE FOLLOWING:

A. SLOPES IN THE DIRECTION OF TRAVEL DO NOT
EXCEED 5%. CROSS SLOPES DO NOT EXCEED 2%.

B. THE CLEAR WIDTH OF ALL WALKWAYS IS 4'-0" MIN.

C. CHANGES IN LEVEL UP TO 1/2" COMPLY WITH
11/A0.2.1. CHANGES IN LEVEL GREATER THAN 1/2" IF
THEY OCCUR ARE RAMPED. SEE PLANS.

D. THE VERTICAL CLEARANCE ALONG THE ACCESSIBLE
ROUTE IS 80" MIN.

7. ALL PAVED AND LANDSCAPED AREAS TO BE BOUND BY A
MIN. 6" HIGH, 6" WIDE CONCRETE CURB U.O.N.

8. A CONCRETE MOW STRIP EXTENDING 12" BEYOND EA
END OF THE OPENING SHALL BE PROVIDED @ ALL
EXTERIOR GLAZING WHERE THE SILL IS WITHIN 3'
VERTICAL OF THE FINISHED GRADE. SEE 2/AD1.1

9. PROVIDE PIPE BOLLARD PROTECTION POSTS AS

REQUIRED BY UTILITY COMPANIES AND OR FIRE

AUTHORITIES AT ALL EXTERIOR ELECTRICAL EQUIPMENT
AND FIRE PREVENTION DEVICES. IF PIPE BOLLARD

PROTECTION POST DETAILS ARE NOT PROVIDED BY

UTILITY COMPANIES AND OR FIRE AUTHORITY SEE DETAIL
3/AD1.1

10. ALL EXPOSED BIORETENSION DEVICE COVERINGS SHALL
BE PAINTED FORREST GREEN.

11. WHERE OCCURS, GENERAL CONTRACTOR TO PROVIDE

FLUID APPLIED DAMP PROOFING AT ALL RETAINING AND

PLANTER WALLS WHERE THE SIDE OF THE WALL

OPPOSITE THE SOIL SIDE IS EXPOSED TO VIEW AND ALL

EXTERIOR WALLS WHERE THE ADJACENT FLOOR SLAB IS
BELOW GRADE. SEE 6/AD1.2

12. PROVIDE A HOSE BIB NEAR THE MAIN BUILDING
ENTRANCE THE . SEE PLAN FOR LOCATION.

13. AN ANTI-GRAFFITI COATING SHALL BE PROVIDE 10 FEET

ON ALL BLOCK WALLS AND STUCCO COVERED WALLS

AND WRITTEN VERIFICATION OF ITS APPLICATION FROM

THE DEVELOPER SHALL BE PROVIDED TO THE PLANNING
DIVISION. THE TYPE AND SPECIFICTION SHALL BE LISTED

WITH THE WALL PLAN DETAILS SUBMITTED TO THE

BUILDING AND SAFETY DIVISION DURING BUILDING PLAN
CHECK.
40' FIRE ACCESS LANE
2000 SF
OFFICE
2000 SF MEZZ
N. WOODSIDE AVE 64' - 0" 416' - 0" 60' - 0" 1500 SF
FUTURE
OFFICE
1500 SF
FUTURE
OFFICE
2000 SF

FUTURE OFFICE
2000 SF MEZZ
2000 SF
OFFICE
2000 SF MEZZ
2000 SF
OFFICE
2000 SF MEZZ
1500 SF

POTENTIAL
OFFICE
1500 SF

POTENTIAL
OFFICE
BUILDING 1
143,708 SF 25 DOCK-HI DOORS 25 DOCK-HI DOORS TYP, U.O.N 52' - 0" 60' - 0"

FIRE ACCESS LANE
38' - 0"
28' FIRE ACCESS LANE
28' FIRE ACCESS LANE 40' FIRE ACCESS LANE
R 68' - 0"
THIS ENTIRE WALL TO BE 3-HOUR FIRE RATED WITH 30" MIN. PARAPETS.

ALL PANEL JOINTS REQUIRE 3-HOUR CAULKING.

DOORS AND OPENINGS REQUIRE 3-HOUR RATING
150
116
111 111 111 111 111 111 111 111 111
111
116
116
115
116
111
111
111
111
111
111 111 111
115
111
116
111
140
140
140 540' - 0" 57' - 3" +/-
111 111
10 10
10 10
11 11 10 10
6 8
6 10 10 10 10 10 10 10 10
61' - 1" +/- 298' - 0" 380' - 0" 59' - 7" +/-
105
BUILDING 2
146,910 SF
151 TYP.
151 TYP.

T
109
1 A1_1
5 A1_2
104 TYP.
1 52' - 0"
A1_2
104
2 A1_1
104
66' - 0"
TYP.
60' - 0"
185
137
137
105 488' - 0"
150
150
150
137
137
137
137 NEIGHBOR'S FENCING 30' - 0" SECONDARY ACCESS GATE WITH KNOX ACCESS NEIGHBOR'S FENCING

NEIGHBOR'S FENCING
10 13
9 14
113
113
112
112
112 112

ADD BARBED WIRE TO

THIS FENCE SEGMENT

ELECTRICAL
ROOM

LONG-TERM

BIKE STORAGE
TYP.
60' - 0" 75' - 0" 19' - 0" 28' - 0" 5' - 7" +/- SETBACK 15' - 0" SETBACK 15' - 0" 75' - 2"

SIDEWALK TO

PUBLIC STREET
147
147
117
3 A1_1
4 A1_1
364' - 5" +/- 67' - 5" 366' - 7" +/-
185' - 0"
2' - 6"
111 TYP. 52' - 0" 64' - 0" 6' - 0" 28' - 0" 19' - 0" TYP. 52' - 0" 72' - 0" 6' - 0" 40' - 0" 19' - 0" 59' - 5" 67' - 0" 59' - 5"
T
11 11
11 11
12 MOTORCYCLE PARKING 3
4 5
2 POTENTIAL

DRIVE-THRU
RAMP

POTENTIAL

DRIVE-THRU
RAMP
28' - 0" 19' - 0" 7' - 6"
116
115
115
116
117
1 A1_3 THIS ENTIRE WALL TO BE 3-HOUR FIRE RATED WITH 30" MIN. PARAPETS. ALL PANEL JOINTS REQUIRE 3-HOUR CAULKING. DOORS AND OPENINGS REQUIRE 3-HOUR RATING 4' - 0"
5' - 6"
63' - 6" +/-
60' - 1" +/-
60' - 5" +/- 58' - 2" +/-

ELECTRICAL
ROOM

LONG-TERM

BIKE STORAGE
59' - 10" +/- 60' - 0"
4' - 0"
4' - 6"
4' - 0"
4' - 10"
4' - 0"

NORTH PROJECT
12/11/2025 1:55:55 PM
A22-2164 SANTEE, CA

12.11.2025
A1

SITE PLAN PALISADE SANTEE COMMERCE CENTER

KEYNOTES

SQUARE FOOTAGE ACRES
587877 SF 13.5

SPACE TYPE SPACES REQUIRED
STANDARD STALLS 226
STANDARD ACCESSIBLE STALLS 6
VAN ACCESSIBLE STALLS 2
EV CAPABLE STALL (w/o EVSE) 44
EVCS (EV CAPABLE STALL w/ EVSE) 13

STANDARD ACCESSIBLE EVCS (EV
CAPABLE STALL w/ EVSE)
1 VAN ACCESSIBLE EVCS (EV CAPABLE
STALL w/ EVSE)
1 TOTAL 293

SPACE TYPE SPACES PROVIDED
STANDARD STALLS 225
STANDARD ACCESSIBLE STALLS 4
VAN ACCESSIBLE STALLS 7
EV CAPABLE STALL (w/o EVSE) 43
EVCS (EV CAPABLE STALL w/ EVSE) 13

STANDARD ACCESSIBLE EVCS (EV
CAPABLE STALL w/ EVSE)
2 VAN ACCESSIBLE EVCS (EV CAPABLE
STALL w/ EVSE)
1 AMBULATORY ACCESSIBLE EVCS (EV
CAPABLE STALL w/ EVSE)
1 TOTAL 296
BUILDING USE BUILDING AREA PARKING RATIO 1/X REQ. PARKING OFFICE AREA 16000 SF 1000 17
WAREHOUSE 274618 SF 1000 275
TOTAL 290618 SF 292

SITE LEGEND

SITE PLAN GENERAL NOTES

SCOPE OF WORK
CONSTRUCT TWO NEW ONE STORY + MEZZANINE CONCRETE

TILT-UP WAREHOUSE/DISTRIBUTION FACILITIES WITH

ELECTRICAL AND PLUMBING SERVICES, EXTERIOR LIGHTING,

LANDSCAPING & IRRIGATION, TRASH ENCLOSURES, TUBE

STEEL PERIMETER FENCING, AND PRE-CAST CONCRETE WALL
BY OTHERS. FIRE SPRINKLER AND GRADING PLANS TO BE A

SEPARATE SUBMITTAL AND PERMIT

LEGAL DESCRIPTION & ZONING
LEGAL DESCRIPTION: SEE CIVIL
ASSESSOR'S PARCEL NO: 381-070-52-00
A0 TITLE SHEET
A1 SITE PLAN
A1_0 SITE UTILIZATION MAP
A1_1 ENLARGED PARTIAL SITE PLANS
A1_2 ENLARGED SITE DETAILS
A1_3 SOUND WALL PLAN & ELEVATIONS
A1_5 FIRE ACCESS PLAN
A2_1 BUILDING 1 GROUND LEVEL FLOOR PLAN
A2_2 BUILDING 2 GROUND LEVEL FLOOR PLAN
A4_1 BUILDING 1 EXTERIOR ELEVATIONS
A4_2 BUILDING 2 EXTERIOR ELEVATIONS
A5 EXTERIOR ELEVATION COLOR BOARD
AD1.1 SITE DETAILS
C1 CONCEPTUAL GRADING PLAN
C2 CONCEPTUAL UTILITY PLAN
FC-1.0 BUILDING 1 PHOTOMETRIC PLAN
FC-2.0 BUILDING 2 PHOTOMETRIC PLAN
L-1 CONCEPTUAL LANDSCAPE PLAN
L-2 LANDSCAPE SECTIONS
R-1 RENDERING
R-2 RENDERING
R-3 RENDERING
R-4 RENDERING
R-5 RENDERING

SHEET INDEX

NORTH PALISADE PARTNERS
1330 FACTORY PLACE #105, LOS ANGELES, CA 90013
CONTACT: BRIAN WONG
PHONE: 310.242.1612
EMAIL: [email protected]
WEBSITE: WWW.NORTHPALISADE.COM

DEVELOPER/OWNER
HERDMAN ARCHITECTURE & DESIGN, INC.
3800 EAST COAST HWY, STE. 6
CORONA DEL MAR, CA 92625
CONTACT: BRIDGET HERDMAN
PHONE: 714.389.2800
EMAIL: [email protected]

APPLICANT'S REPRESENTATIVE/ARCHITECT

VICINITY MAP

TOTAL PARKING REQUIRED

REQUIRED PARKING BREAKDOWN

PARKING PROVIDED

LANDSCAPE AREA SUMMARY

BUILDING AREA SUMMARY

FLOOR AREA RATIO

LOT AREA

BUILDING AREA SITE AREA FAR ALLOWABLE FAR PROVIDED
290618 SF 587877 SF 100% 49.4%
104 ASPHALT PAVING. SEE CIVIL DRAWINGS FOR ADDITIONAL
INFORMATION.
105 CONCRETE PAVING. SEE CIVIL DRAWINGS FOR ADITIONAL

INFORMATION (SEE STRUCTURAL DRAWINGS FOR TRUCK
APRON WHEN NOT COVERED BY CIVIL DRAWINGS).
109 (N) TRANSFORMER LOCATION. PROVIDE PIPE BOLLARD

PROTECTION POSTS PER UTILITY COMPANY
REQUIREMENTS. SEE ELECTRICAL DRAWINGS FOR
ADITIONAL INFORMATION.
111 TYP U.O.N., STANDARD PARKING STALL. SEE 1/A1.0.
112 EV (ELECTRIC VEHICLE) CAPABLE PARKING STALL. SEE
1/A1.0 AND ELECTRICAL DRAWINGS.
113 EVCS (ELECTRIC VEHICLE CHARGING STATION) PARKING
STALL. SEE 1/A1.0 AND ELECTRICAL DRAWINGS.
115 STANDARD ACCESSIBLE PARKING STALL. FOR DETAIL
SHOWN BUT NOT NOTED, SEE 1/A0.2.1.
116 VAN ACCESSIBLE PARKING STALL. FOR DETAIL SHOWN
BUT NOT NOTED, SEE 1/A0.2.1.
117 STANDARD ACCESSIBLE EVCS (ELECTRICAL VEHICLE
CHARGING STATION). SEE ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION. FOR DETAIL SHOWN BUT NOT
NOTED, SEE 2/A0.2.1.
137 TUBE STEEL FENCE. MIN HEIGHT 8' ABOVE HIGHEST
ADJACENT FINISHED GRADE. SEE 7/AD1.1.
140 TRASH ENCLOSURE w/ROOF COVERING AS REQUIRED BY
JURISDICTION. SEE CIVIL & STRUCTURAL DRAWINGS FOR
ADDITIONAL INFORMATION.
147 2 POSITION BIKE RACK. SEE 8/AD1.2.
150 CONCRETE TRUCK RAMP w/ 42" HIGH CONCRETE TILT-UP
GUARD ON OPEN SIDE(S). PAINT ALL SIDES OF GUARD
WALLS AND HANDRAILS.SEE ARCHITECTURAL DRAWINGS
FOR COLOR SCHEDULE. SEE STRUCTURAL DRAWINGS FOR
ADDITIONAL INFORMATION.
151 STEEL PIPE BOLLARD PROTECTION POST. SEE 3/AD1.1.
185 FIRE SPRINKLER RISER. PROVIDE PIPE BOLLARD
PROTECTION POSTS. SEE 7/AD5.0 AND FIRE PROTECTION
PLANS.

BUILDING ADDRESS: 10990 WOODSIDE AVE.

SANTEE, CA 92071
CONSTRUCTION TYPE: III-B
OCCUPANCY: B / S-1
FIRE SPRINKLER: YES (ESFR NFPA 72, NFPA 13 & NFPA 24)
CLEAR HEIGHT: 36'
ZONING:

GENERAL PLAN: G-I (GENERAL INDUSTRIAL)
SPECIFIC PLAN: N/A
FEMA FLOOD ZONE: NO FLOOD ZONE
BUILDING SETBACKS:

FRONT SETBACK: 15'
SIDE SETBACK: 5'
REAR SETBACK: NONE
ALLOWABLE AREA:

UNLIMITED AREA PER CBC 507 TABLE 506.2

PROJECT INFORMATION & AREA ANALYSIS
1" = 40'-0" 1 PROPOSED SITE PLAN
TOTAL BUILDING AREA 143708 SF

TOTAL AREA BY OCCUPANCY
WAREHOUSE 135708 SF
OFFICE AREA 8000 SF

FINISH FLOOR
WAREHOUSE BUILDING 1 135708 SF
OFFICE BUILDING 1 2000 SF
OFFICE BUILDING 1 2000 SF

MEZZANINE
OFFICE BUILDING 1 2000 SF
OFFICE BUILDING 1 2000 SF
TOTAL FINISH FLOOR AREA 139708 SF
TOTAL MEZZANINE AREA 4000 SF

FINISH FLOOR
WAREHOUSE BUILDING 2 138910 SF
OFFICE BUILDING 2 2000 SF
OFFICE BUILDING 2 2000 SF

MEZZANINE
OFFICE BUILDING 2 2000 SF
OFFICE BUILDING 2 2000 SF
TOTAL FINISH FLOOR AREA 142910 SF
TOTAL MEZZANINE AREA 4000 SF
TOTAL BUILDING AREA 146910 SF
BUILDING 2
BUILDING 1
*SEE LANDSCAPE PLAN
Accessible path shall connect to public sidewalk sheet A1

ACCESSIBLE PATH SHALL
CONNECT TO PUBLIC SIDEWALK.

FH FH
FH FH
FH
FH
FH
FH
FH
FH
FH
FH
2000 SF

FUTURE OFFICE
2000 SF MEZZ
2000 SF

FUTURE OFFICE
2000 SF MEZZ
2000 SF

FUTURE OFFICE
2000 SF MEZZ
2000 SF

FUTURE OFFICE
2000 SF MEZZ

PROPOSED
BUILDING 1

PROPOSED
BUILDING 2
28' FIRE ACCESS LANE
P
R
E
-
CAST
C
O
N
C
R
E
TE
F
E
N
C
E
28' FIRE ACCESS LANE
NORTH

PROJECT
10/31/2025 10:02:08 AM
A22-2164

SANTEE, CA
6TH PLANNING
SUBMITTAL10.31.25
A1_0
SITE

UTILIZATION
MAP

PALISADE SANTEE COMMERCE CENTER
1" = 80'-0"
1 SITE UTILIZATION MAP
FH
FH FH

LANDSCAPE AREA

CONCRETE PAVING WHEN OCCURS
@ PARKING AREAS, DRIVE AISLES,
& OR TRUCK COURT. SEE CIVIL

DRAWINGS FOR PAVING SECTIONS
FIRE HYDRANT. PROVIDE PIPE

BOLLARD PROTECTION POSTS AS

REQUIRED BY THE FIRE
AUTHORITY. SEE 3/AD1.1

LIGHT POLE
INDICATES AN ACCESSIBLE ROUTE.

MUST COMPLY w/ SITE PLAN
GENERAL NOTE #6

PROPERTY LINE

PROPOSED OFFICE

DOCK HIGH TRUCK DOOR
GRADE LEVEL TRUCK DOOR # PARKING STALL COUNT TOTAL

FIRE LANE PER DEPARTMENT

REQUIREMENT
NOTES:

1. ALL IMPERFECTIONS ON THE SURFACE OF THE CONCRETE

WALL PANELS SHALL BE PATCHED / SACKED / SANDED
SMOOTH PRIOR TO PAINTING.

2. ALL EXTERIOR FABRICATED STEEL SHALL BE SHOP PRIMED

WITH A GRAY, RUST INHIBITIVE PRIMER PRIOR TO DELIVERY
TO THE JOB SITE. ANY AND ALL DAMAGE TO THE PRIMER

COAT SHALL BE TOUCHED UP PRIOR TO ADDITIONAL FINAL
COLOR PAINTING OR COMPLETION OF THE PROJECT.

3. POWER WASH EXTERIOR CONCRETE WALLS PRIOR TO

PAINTING TO REMOVE ALL CHEMICALS AND DIRT THAT WILL

IMPEDE THE PRIMER COAT FROM ADHERING TO THE
WALLS.

4. PAINT EXTERIOR WALLS w/ 1- COAT SPRAYED AND BACK
ROLLED ACRYLIC FLAT PRIMER AND 2-COATS SPRAYED-ON
FLAT FINISH IN THE FINAL WALL COLOR. FINISHED JOB

SHALL BE SMOOTH AND FREE OF LAPPING AND OR
STREAKING, REGARDLESS OF THE COLOR.

5. EXCEPT WHERE NOTED OTHERWISE ON THE PLANS ALL
PANEL JOINTS SHALL BE CAULKED PER DETAIL 1/AD4.1.

6. PAINT CONCRETE BEHIND ANY OPEN TRELLIS WORK THE
COLOR OF THE TRELLIS.

7. PAINT ALL WALL REVEALS THE COLOR OF THE ADJACENT
WALL. WHEN THERE IS A COLOR CHANGE AT THE REVEAL,
SEE 2/AD4.1

8. U.O.N., PAINT THE SIDE OPPOSITE THE SIDE SHOWN OF
SCREEN WALLS THE SAME COLOR AS THE SIDE SHOWN. IF
THERE ARE TWO COLORS SHOWN, USE THE BASE COLOR.

9. ALL PAINTS USED SHALL BE AS SPECIFIED BY THE

MANUFACTURER FOR THE PROPOSED USE

10. PAINT COLOR FOR EXPOSED CANOPY FRAMING & WALL
BEHIND OPEN TRELLIS (KEY NOTE 428, OR 429) WHEN

OCCURS & TRASH ENCLOSURE METAL ROOF, ROOF BEAMS,
& SUPPORT COLUMNS PER COLOR LEGEND ON THIS
SHEET. LIGHT POLE BASES TO REMAIN UNPAINTED AND
SMOOTH FINISH CONCRETE.

11. REFER TO DIGITAL COPY OF PLANS FOR RENDERING AND
ELEVATIONS IN COLOR. HARD COPY PLANS WILL SHOWN
BLACK AND WHITE ONLY. A
EXTERIOR PAINT COLOR: SW 6995

SUPERWHITE B
EXTERIOR PAINT COLOR: SW 7666 FLEUR DE
SEL C
EXTERIOR PAINT COLOR: SW 7674

PEPPERCORN D

STOREFRONT MEDIUM PERFORMANCE BLUE

REFLECTED GLAZING BLACK ANODIZED

MULLION E METAL PANEL F BLACK ANODIZED METAL CANOPY/BROW

1. THE SITE PLAN SHALL MEET ALL ENGINEERING & NPDES
REQUIREMENTS.

2. GENERAL CONTRACTOR TO REVIEW THE SOILS REPORT

AND ALL AMMENDMENTS LISTED ON THE TITLE SHEET
AND FOLLOW ALL RECOMMENDATIONS.

3. U.O.N., ALL DIMENSIONS TO CONCRETE WALLS AND

CURBS ARE EITHER TO THE CENTER (SHOWN WITH A
CENTERLINE) OR FACE OF THE WALL OR CURB. ALL

DIMESIONS TO FRAMED WALLS ARE EITHER TO THE

CENTER LINE OF THE WALL FRAMING (SHOWN WITH A
CENTERLINE) OR THE FACE OF THE WALL FINISH.

4. REFER TO CIVIL, AND MEP PLANS TO CONFIRM UTILITY

INFORMATION SHOWN ON THE ARCHITECT'S SITE PLAN
AND FOR ADDITIONAL UTILITY INFORMATION. GENERAL

CONTRACTOR TO COORDINATE ALL POINTS OF
CONNECTION.

5. REFER TO CIVIL DRAWINGS FOR ALL FINISHED GRADES
AND SLOPES. ALL FINISHED GRADES TO PROVIDE
POSITIVE DRAINAGE AWAY FROM THE BUILDING.

GENERAL CONTRACTOR TO FIELD VERIFY.

6. ALL ACCESSIBLE ROUTES INDENTIFIED ON THE SITE PLAN
DRAWINGS SHALL CONFORM TO THE FOLLOWING:

A. SLOPES IN THE DIRECTION OF TRAVEL DO NOT
EXCEED 5%. CROSS SLOPES DO NOT EXCEED 2%.

B. THE CLEAR WIDTH OF ALL WALKWAYS IS 4'-0" MIN.

C. CHANGES IN LEVEL UP TO 1/2" COMPLY WITH
11/A0.2.1. CHANGES IN LEVEL GREATER THAN 1/2" IF
THEY OCCUR ARE RAMPED. SEE PLANS.

D. THE VERTICAL CLEARANCE ALONG THE ACCESSIBLE
ROUTE IS 80" MIN.

7. ALL PAVED AND LANDSCAPED AREAS TO BE BOUND BY A
MIN. 6" HIGH, 6" WIDE CONCRETE CURB U.O.N.

8. A CONCRETE MOW STRIP EXTENDING 12" BEYOND EA
END OF THE OPENING SHALL BE PROVIDED @ ALL
EXTERIOR GLAZING WHERE THE SILL IS WITHIN 3'
VERTICAL OF THE FINISHED GRADE. SEE 2/AD1.1

9. PROVIDE PIPE BOLLARD PROTECTION POSTS AS

REQUIRED BY UTILITY COMPANIES AND OR FIRE

AUTHORITIES AT ALL EXTERIOR ELECTRICAL EQUIPMENT
AND FIRE PREVENTION DEVICES. IF PIPE BOLLARD

PROTECTION POST DETAILS ARE NOT PROVIDED BY

UTILITY COMPANIES AND OR FIRE AUTHORITY SEE DETAIL
3/AD1.1

10. ALL EXPOSED BIORETENSION DEVICE COVERINGS SHALL
BE PAINTED FORREST GREEN.

11. WHERE OCCURS, GENERAL CONTRACTOR TO PROVIDE

FLUID APPLIED DAMP PROOFING AT ALL RETAINING AND

PLANTER WALLS WHERE THE SIDE OF THE WALL

OPPOSITE THE SOIL SIDE IS EXPOSED TO VIEW AND ALL

EXTERIOR WALLS WHERE THE ADJACENT FLOOR SLAB IS
BELOW GRADE. SEE 6/AD1.2

12. PROVIDE A HOSE BIB NEAR THE MAIN BUILDING
ENTRANCE THE . SEE PLAN FOR LOCATION.

13. AN ANTI-GRAFFITI COATING SHALL BE PROVIDE 10 FEET

ON ALL BLOCK WALLS AND STUCCO COVERED WALLS

AND WRITTEN VERIFICATION OF ITS APPLICATION FROM

THE DEVELOPER SHALL BE PROVIDED TO THE PLANNING
DIVISION. THE TYPE AND SPECIFICTION SHALL BE LISTED

WITH THE WALL PLAN DETAILS SUBMITTED TO THE

BUILDING AND SAFETY DIVISION DURING BUILDING PLAN
CHECK.
2000 SF

FUTURE OFFICE
2000 SF MEZZ
112
116
112
117
121
123
123 4' - 0"
120
120
121
147
122
122
4' - 10" 19' - 0" 9' - 0" 12' - 0"
110
2000 SF

FUTURE OFFICE
2000 SF MEZZ
112
117
116
146
105 9' - 0" 9' - 0"
3' - 0"
121
120
172
122
120
122
123
4' - 10"
105
116
110
123
121 4' - 0"
120 12' - 0"
148
147
122
2000 SF

FUTURE OFFICE
2000 SF MEZZ
123 9' - 0" TYP. CURB RAMP 6' - 0" 12' - 0"
123
115
116
105
148
TYP.
120
2000 SF

FUTURE OFFICE
2000 SF MEZZ 9' - 0" 5' - 0"
122
4' - 0"
147

NORTH PROJECT
12/11/2025 1:59:01 PM
A22-2164 SANTEE, CA

12.11.2025
A1_1

ENLARGED

SITE PLANS PALISADE SANTEE COMMERCE CENTER

KEYNOTES

EXTERIOR COLOR SCHEDULE
105 CONCRETE PAVING. SEE CIVIL DRAWINGS FOR ADITIONAL

INFORMATION (SEE STRUCTURAL DRAWINGS FOR TRUCK
APRON WHEN NOT COVERED BY CIVIL DRAWINGS).
110 ACCESS AISLE FOR ACCESSIBLE PARKING STALLS. SEE 1 & 2/A0.2.1.
112 EV (ELECTRIC VEHICLE) CAPABLE PARKING STALL. SEE
1/A1.0 AND ELECTRICAL DRAWINGS.
115 STANDARD ACCESSIBLE PARKING STALL. FOR DETAIL
SHOWN BUT NOT NOTED, SEE 1/A0.2.1.
116 VAN ACCESSIBLE PARKING STALL. FOR DETAIL SHOWN
BUT NOT NOTED, SEE 1/A0.2.1.
117 STANDARD ACCESSIBLE EVCS (ELECTRICAL VEHICLE
CHARGING STATION). SEE ELECTRICAL DRAWINGS FOR
ADDITIONAL INFORMATION. FOR DETAIL SHOWN BUT NOT
NOTED, SEE 2/A0.2.1.
120 TRUNCATED DOME DETECTABLE WARNING SURFACE. 3'-0"
DEEP IN THE DIRECTION OF TRAVEL. SEE 10/A0.2.1.
121 PRECAST CONCRETE WHEEL STOP. SEE 5/AD1.1.
122 ZERO CURB FACE. SEE CIVIL DRAWINGS FOR ADDITIONAL
INFORMATION.
123 CURB RAMP. 8.33% MAX SLOPE w/ 2% MAX CROSS SLOPE.

SEE CIVIL DRAWINGS FOR ADDITIONAL INFORMATION.
146 PAINTED STEEL SWINGING PEDESTRIAN GATE. WHEN
OCCURS IN TUBE STEEL FENCE, ALIGN TOP w/ FENCE
HEIGHT. WHEN OCCURS IN CONCRETE SCREEN WALL,
REFER TO SITE WALL ELEVATIONS. SEE 8/AD1.1. PROVIDE
KNOX BOX AS REQUIRED BY FIRE AUTHORITY.
147 2 POSITION BIKE RACK. SEE 8/AD1.2.
148 OUTDOOR EMPLOYEE BREAK AREA.
172 LOCATION OF FUTURE MEDIUM AND HEAVY DUTY ZEV

CHARGING CABINETS AND CHARGING DISPENSERS FOR
TRUCK CHARGING ONLY. SEE ELECTRICAL DRAWINGS.

SITE PLAN GENERAL NOTES

SITE LEGEND
1/8" = 1'-0" 1 ENLARGED SITE PLAN SOUTHEAST1/8" = 1'-0" 2 ENLARGED SITE PLAN SOUTHWEST 1/8" = 1'-0" 3 ENLARGED SITE PLAN - NORTHWEST OFFICE1/8" = 1'-0" 4 ENLARGED SITE PLAN - NORTHEAST CORNER FH
6' - 5"
MIN
. CLR
5'
- 0"
ø
15' - 0"
7' - 9"
142
A1_2 3
A1_2 4
A1_2
2 6 A1_2
2' - 6"
3' - 0"
AB
7' - 0"10' - 0"4' - 8"
6' - 6"
109

LANDSCAPE AREA

CONCRETE PAVING WHEN OCCURS
@ PARKING AREAS, DRIVE AISLES,
& OR TRUCK COURT. SEE CIVIL

DRAWINGS FOR PAVING SECTIONS
FIRE HYDRANT. PROVIDE PIPE

BOLLARD PROTECTION POSTS AS

REQUIRED BY THE FIRE
AUTHORITY. SEE 3/AD1.1

LIGHT POLE
INDICATES AN ACCESSIBLE ROUTE.

MUST COMPLY w/ SITE PLAN
GENERAL NOTE #6

PROPERTY LINE

PROPOSED OFFICE

DOCK HIGH TRUCK DOOR

GRADE LEVEL TRUCK DOOR
# PARKING STALL COUNT TOTAL

FIRE LANE PER DEPARTMENT

REQUIREMENT
NOTES:

1. ALL IMPERFECTIONS ON THE SURFACE OF THE CONCRETE

WALL PANELS SHALL BE PATCHED / SACKED / SANDED
SMOOTH PRIOR TO PAINTING.

2. ALL EXTERIOR FABRICATED STEEL SHALL BE SHOP PRIMED

WITH A GRAY, RUST INHIBITIVE PRIMER PRIOR TO DELIVERY
TO THE JOB SITE. ANY AND ALL DAMAGE TO THE PRIMER

COAT SHALL BE TOUCHED UP PRIOR TO ADDITIONAL FINAL
COLOR PAINTING OR COMPLETION OF THE PROJECT.

3. POWER WASH EXTERIOR CONCRETE WALLS PRIOR TO

PAINTING TO REMOVE ALL CHEMICALS AND DIRT THAT WILL

IMPEDE THE PRIMER COAT FROM ADHERING TO THE
WALLS.

4. PAINT EXTERIOR WALLS w/ 1- COAT SPRAYED AND BACK
ROLLED ACRYLIC FLAT PRIMER AND 2-COATS SPRAYED-ON
FLAT FINISH IN THE FINAL WALL COLOR. FINISHED JOB

SHALL BE SMOOTH AND FREE OF LAPPING AND OR
STREAKING, REGARDLESS OF THE COLOR.

5. EXCEPT WHERE NOTED OTHERWISE ON THE PLANS ALL
PANEL JOINTS SHALL BE CAULKED PER DETAIL 1/AD4.1.

6. PAINT CONCRETE BEHIND ANY OPEN TRELLIS WORK THE
COLOR OF THE TRELLIS.

7. PAINT ALL WALL REVEALS THE COLOR OF THE ADJACENT
WALL. WHEN THERE IS A COLOR CHANGE AT THE REVEAL,
SEE 2/AD4.1

8. U.O.N., PAINT THE SIDE OPPOSITE THE SIDE SHOWN OF
SCREEN WALLS THE SAME COLOR AS THE SIDE SHOWN. IF
THERE ARE TWO COLORS SHOWN, USE THE BASE COLOR.

9. ALL PAINTS USED SHALL BE AS SPECIFIED BY THE

MANUFACTURER FOR THE PROPOSED USE

10. PAINT COLOR FOR EXPOSED CANOPY FRAMING & WALL
BEHIND OPEN TRELLIS (KEY NOTE 428, OR 429) WHEN

OCCURS & TRASH ENCLOSURE METAL ROOF, ROOF BEAMS,
& SUPPORT COLUMNS PER COLOR LEGEND ON THIS
SHEET. LIGHT POLE BASES TO REMAIN UNPAINTED AND
SMOOTH FINISH CONCRETE.

11. REFER TO DIGITAL COPY OF PLANS FOR RENDERING AND
ELEVATIONS IN COLOR. HARD COPY PLANS WILL SHOWN
BLACK AND WHITE ONLY. A
EXTERIOR PAINT COLOR: SW 6995

SUPERWHITE
B
EXTERIOR PAINT COLOR: SW 7666 FLEUR DE
SEL
C
EXTERIOR PAINT COLOR: SW 7674

PEPPERCORN
D

STOREFRONT MEDIUM PERFORMANCE BLUE

REFLECTED GLAZING BLACK ANODIZED

MULLION

E METAL PANEL F BLACK ANODIZED METAL CANOPY/BROW

1. THE SITE PLAN SHALL MEET ALL ENGINEERING & NPDES
REQUIREMENTS.

2. GENERAL CONTRACTOR TO REVIEW THE SOILS REPORT

AND ALL AMMENDMENTS LISTED ON THE TITLE SHEET
AND FOLLOW ALL RECOMMENDATIONS.

3. U.O.N., ALL DIMENSIONS TO CONCRETE WALLS AND

CURBS ARE EITHER TO THE CENTER (SHOWN WITH A
CENTERLINE) OR FACE OF THE WALL OR CURB. ALL

DIMESIONS TO FRAMED WALLS ARE EITHER TO THE

CENTER LINE OF THE WALL FRAMING (SHOWN WITH A
CENTERLINE) OR THE FACE OF THE WALL FINISH.

4. REFER TO CIVIL, AND MEP PLANS TO CONFIRM UTILITY

INFORMATION SHOWN ON THE ARCHITECT'S SITE PLAN
AND FOR ADDITIONAL UTILITY INFORMATION. GENERAL

CONTRACTOR TO COORDINATE ALL POINTS OF
CONNECTION.

5. REFER TO CIVIL DRAWINGS FOR ALL FINISHED GRADES
AND SLOPES. ALL FINISHED GRADES TO PROVIDE
POSITIVE DRAINAGE AWAY FROM THE BUILDING.

GENERAL CONTRACTOR TO FIELD VERIFY.

6. ALL ACCESSIBLE ROUTES INDENTIFIED ON THE SITE PLAN
DRAWINGS SHALL CONFORM TO THE FOLLOWING:

A. SLOPES IN THE DIRECTION OF TRAVEL DO NOT
EXCEED 5%. CROSS SLOPES DO NOT EXCEED 2%.

B. THE CLEAR WIDTH OF ALL WALKWAYS IS 4'-0" MIN.

C. CHANGES IN LEVEL UP TO 1/2" COMPLY WITH
11/A0.2.1. CHANGES IN LEVEL GREATER THAN 1/2" IF
THEY OCCUR ARE RAMPED. SEE PLANS.

D. THE VERTICAL CLEARANCE ALONG THE ACCESSIBLE
ROUTE IS 80" MIN.

7. ALL PAVED AND LANDSCAPED AREAS TO BE BOUND BY A
MIN. 6" HIGH, 6" WIDE CONCRETE CURB U.O.N.

8. A CONCRETE MOW STRIP EXTENDING 12" BEYOND EA
END OF THE OPENING SHALL BE PROVIDED @ ALL
EXTERIOR GLAZING WHERE THE SILL IS WITHIN 3'
VERTICAL OF THE FINISHED GRADE. SEE 2/AD1.1

9. PROVIDE PIPE BOLLARD PROTECTION POSTS AS

REQUIRED BY UTILITY COMPANIES AND OR FIRE

AUTHORITIES AT ALL EXTERIOR ELECTRICAL EQUIPMENT
AND FIRE PREVENTION DEVICES. IF PIPE BOLLARD

PROTECTION POST DETAILS ARE NOT PROVIDED BY

UTILITY COMPANIES AND OR FIRE AUTHORITY SEE DETAIL
3/AD1.1

10. ALL EXPOSED BIORETENSION DEVICE COVERINGS SHALL
BE PAINTED FORREST GREEN.

11. WHERE OCCURS, GENERAL CONTRACTOR TO PROVIDE

FLUID APPLIED DAMP PROOFING AT ALL RETAINING AND

PLANTER WALLS WHERE THE SIDE OF THE WALL

OPPOSITE THE SOIL SIDE IS EXPOSED TO VIEW AND ALL

EXTERIOR WALLS WHERE THE ADJACENT FLOOR SLAB IS
BELOW GRADE. SEE 6/AD1.2

12. PROVIDE A HOSE BIB NEAR THE MAIN BUILDING
ENTRANCE THE . SEE PLAN FOR LOCATION.

13. AN ANTI-GRAFFITI COATING SHALL BE PROVIDE 10 FEET

ON ALL BLOCK WALLS AND STUCCO COVERED WALLS

AND WRITTEN VERIFICATION OF ITS APPLICATION FROM

THE DEVELOPER SHALL BE PROVIDED TO THE PLANNING
DIVISION. THE TYPE AND SPECIFICTION SHALL BE LISTED

WITH THE WALL PLAN DETAILS SUBMITTED TO THE

BUILDING AND SAFETY DIVISION DURING BUILDING PLAN
CHECK.

OPEN BEYOND
3' - 0"
151

HIGHEST ADJACENT GRADE
6' - 0" MIN. HEIGHT ABOVE
151
AB

ABOVE ADJACENT GRADE
6' - 0" MIN. HEIGHT 3' - 0"
NORTH

PROJECT
10/31/2025 10:02:16 AM
A22-2164

SANTEE, CA
6TH PLANNING
SUBMITTAL10.31.25
A1_2

ENLARGED

SITE PLANS II

PALISADE SANTEE COMMERCE CENTER
1/4" = 1'-0"
1 ENLARGED SITE PLAN - TRASH ENCLOSURE, TYP.
1/4" = 1'-0"
3 TRASH ENCLOSURE SOUTH ELEVATION
1/4" = 1'-0"
4 TRASH ENCLOSURE NORTH ELEVATION II
1/4" = 1'-0"
5 ENLARGED SITE PLAN - TRANSFORMER

KEYNOTES

EXTERIOR COLOR SCHEDULE
109 (N) TRANSFORMER LOCATION. SEE LANDSCAPE FOR

SCREENING
142 CONCRETE TILT-UP TRASH ENCLOSURE WALL. MIN HEIGHT
6'-0" ABOVE HIGHEST ADJACENT FINISHED GRADE. PAINT
BOTH SIDES AND TOP OF WALL. SEE PLANS FOR COLOR

SCHEDULE
151 STEEL PIPE BOLLARD PROTECTION POST

SITE PLAN GENERAL NOTES

SITE LEGEND
1/4" = 1'-0"
2 TRASH ENCLOSURE WEST ELEVATION
1/4" = 1'-0"
6 TRASH ENCLOSURE EAST ELEVATION
NOTES:

1. ALL IMPERFECTIONS ON THE SURFACE OF THE CONCRETE

WALL PANELS SHALL BE PATCHED / SACKED / SANDED
SMOOTH PRIOR TO PAINTING.

2. ALL EXTERIOR FABRICATED STEEL SHALL BE SHOP PRIMED

WITH A GRAY, RUST INHIBITIVE PRIMER PRIOR TO DELIVERY
TO THE JOB SITE. ANY AND ALL DAMAGE TO THE PRIMER

COAT SHALL BE TOUCHED UP PRIOR TO ADDITIONAL FINAL
COLOR PAINTING OR COMPLETION OF THE PROJECT.

3. POWER WASH EXTERIOR CONCRETE WALLS PRIOR TO

PAINTING TO REMOVE ALL CHEMICALS AND DIRT THAT WILL

IMPEDE THE PRIMER COAT FROM ADHERING TO THE
WALLS.

4. PAINT EXTERIOR WALLS w/ 1- COAT SPRAYED AND BACK
ROLLED ACRYLIC FLAT PRIMER AND 2-COATS SPRAYED-ON
FLAT FINISH IN THE FINAL WALL COLOR. FINISHED JOB

SHALL BE SMOOTH AND FREE OF LAPPING AND OR
STREAKING, REGARDLESS OF THE COLOR.

5. EXCEPT WHERE NOTED OTHERWISE ON THE PLANS ALL
PANEL JOINTS SHALL BE CAULKED PER DETAIL 1/AD4.1.

6. PAINT CONCRETE BEHIND ANY OPEN TRELLIS WORK THE
COLOR OF THE TRELLIS.

7. PAINT ALL WALL REVEALS THE COLOR OF THE ADJACENT
WALL. WHEN THERE IS A COLOR CHANGE AT THE REVEAL,
SEE 2/AD4.1

8. U.O.N., PAINT THE SIDE OPPOSITE THE SIDE SHOWN OF
SCREEN WALLS THE SAME COLOR AS THE SIDE SHOWN. IF
THERE ARE TWO COLORS SHOWN, USE THE BASE COLOR.

9. ALL PAINTS USED SHALL BE AS SPECIFIED BY THE

MANUFACTURER FOR THE PROPOSED USE

10. PAINT COLOR FOR EXPOSED CANOPY FRAMING & WALL
BEHIND OPEN TRELLIS (KEY NOTE 428, OR 429) WHEN

OCCURS & TRASH ENCLOSURE METAL ROOF, ROOF BEAMS,
& SUPPORT COLUMNS PER COLOR LEGEND ON THIS
SHEET. LIGHT POLE BASES TO REMAIN UNPAINTED AND
SMOOTH FINISH CONCRETE.

11. REFER TO DIGITAL COPY OF PLANS FOR RENDERING AND
ELEVATIONS IN COLOR. HARD COPY PLANS WILL SHOWN
BLACK AND WHITE ONLY. A
EXTERIOR PAINT COLOR: SW 6995

SUPERWHITE
B
EXTERIOR PAINT COLOR: SW 7666 FLEUR DE
SEL
C
EXTERIOR PAINT COLOR: SW 7674

PEPPERCORN
D

STOREFRONT MEDIUM PERFORMANCE BLUE

REFLECTED GLAZING BLACK ANODIZED

MULLION

E METAL PANEL F BLACK ANODIZED METAL CANOPY/BROW
A1_3 2

ABOVE GRADE
10' - 0"
3 A1_3
10' - 0"
STANDARD CMU BLOCKS, TYP.

NORTH

PROJECT
10/31/2025 10:02:17 AM
A22-2164

SANTEE, CA
6TH PLANNING
SUBMITTAL10.31.25
A1_3

SOUND WALL
PLAN &

ELEVATIONS

PALISADE SANTEE COMMERCE CENTER

EXTERIOR COLOR SCHEDULE

KEYNOTES
1/4" = 1'-0"
1 ENLARGED SOUND WALL PLAN
1/4" = 1'-0"
2 SOUND WALL NORTH ELEVATION
1" = 1'-0"
3 SOUND WALL SECTION
FH
FH FH
FH FH
FH
FH
FH
FH
FH
FH
FH
FH
FH
FH

LANDSCAPE AREA

CONCRETE PAVING WHEN OCCURS
@ PARKING AREAS, DRIVE AISLES,
& OR TRUCK COURT. SEE CIVIL

DRAWINGS FOR PAVING SECTIONS
FIRE HYDRANT. PROVIDE PIPE

BOLLARD PROTECTION POSTS AS

REQUIRED BY THE FIRE
AUTHORITY. SEE 3/AD1.1

LIGHT POLE
INDICATES AN ACCESSIBLE ROUTE.

MUST COMPLY w/ SITE PLAN
GENERAL NOTE #6

PROPERTY LINE

PROPOSED OFFICE

DOCK HIGH TRUCK DOOR

GRADE LEVEL TRUCK DOOR
# PARKING STALL COUNT TOTAL

FIRE LANE PER DEPARTMENT

REQUIREMENT
40' FIRE ACCESS LANE
2000 SF
OFFICE
2000 SF MEZZ
N. WOODSIDE AVE
1500 SF
FUTURE
OFFICE
1500 SF
FUTURE
OFFICE
2000 SF

FUTURE OFFICE
2000 SF MEZZ
2000 SF
OFFICE
2000 SF MEZZ
2000 SF
OFFICE
2000 SF MEZZ
1500 SF

POTENTIAL
OFFICE
1500 SF

POTENTIAL
OFFICE
BUILDING 1
143,708 SF
25 DOCK-HI DOORS
25 DOCK-HI DOORS
TYP, U.O.N
52' - 0" 60' - 0"
28' FIRE ACCESS LANE
28' FIRE ACCESS LANE
40' FIRE ACCESS LANE
R 68' - 0"
THIS ENTIRE WALL TO BE 3-HOUR FIRE RATED WITH 30" MIN. PARAPETS.

ALL PANEL JOINTS REQUIRE 3-HOUR CAULKING.

DOORS AND OPENINGS REQUIRE 3-HOUR RATING
540' - 0"
10 10
10 10
11 11 10 10
6 8
6 10 10 10 10 10 10 10 10
60' - 10" +/- 298' - 0" 380' - 0"
BUILDING 2
146,910 SF
T
TYP.
52' - 0"
66' - 0"
TYP.
60' - 0"
THIS ENTIRE WALL TO BE 3-HOUR FIRE RATED WITH 30" MIN.

PARAPETS. ALL PANEL JOINTS REQUIRE 3-HOUR CAULKING.

DOORS AND OPENINGS REQUIRE 3-HOUR RATING

NEIGHBOR'S FENCING
30' - 0"

SECONDARY

ACCESS GATE

WITH KNOX
ACCESS

NEIGHBOR'S FENCING

NEIGHBOR'S FENCING
10 13
9 14
ELECT.

ROOM

LONG-TERM

BIKE STORAGE
TYP.
60' - 0" 67' - 0"
8' - 0"
19' - 0" 28' - 0"

SETBACK
15' - 0"

SETBACK
15' - 0"
75' - 0"

SIDEWALK TO

PUBLIC STREET
58' - 2" +/-
62' - 3" +/- 302' - 2" +/- 67' - 5" 305' - 7" 61' - 2" +/- 246' - 0" 185' - 0" 247' - 0"
2' - 10"
TYP.
52' - 0"64' - 0"6' - 0"28' - 0"19' - 0"
TYP.
52' - 0"72' - 0"6' - 0"40' - 0"19' - 0"
59' - 0" 67' - 0" 59' - 0"
T
11 11
11 11
12 THIS ENTIRE WALL TO BE 3-HOUR FIRE RATED WITH 30" MIN. PARAPETS.

ALL PANEL JOINTS REQUIRE 3-HOUR CAULKING.

DOORS AND OPENINGS REQUIRE 3-HOUR RATING
MOTORCYCLE PARKING 3
4 5
2 28' - 0" 19' - 0"
7' - 6"
28' FIRE ACCESS LANE28' FIRE ACCESS LANE28' FIRE ACCESS LANE28' FIRE ACCESS LANE 651' - 7" 70' - 1" +/-
73' - 6" 38' - 0" 73' - 6"
40' FIRE ACCESS LANE
28' FIRE ACCESS LANE
38' FIRE ACCESS LANE38' FIRE ACCESS LANE
45' - 0"
17' x 45' FIRE

DEPLOYMENT AREA
17' x 45' FIRE

DEPLOYMENT AREA
17' x 45' FIRE

DEPLOYMENT AREA
17' x 45' FIRE

DEPLOYMENT AREA
17' x 45' FIRE

DEPLOYMENT AREA
17' x 45' FIRE

DEPLOYMENT AREA
134
130 TYP.
134
33' - 3" +/-
NORTH

PROJECT
10/31/2025 11:06:28 AM
A22-2164

SANTEE, CA
6TH PLANNING
SUBMITTAL10.31.25
A1_5

FIRE ACCESS
PLAN

PALISADE SANTEE COMMERCE CENTER

SITE LEGEND KEYNOTES
130 (N) FIRE HYDRANT
134 FIRE DEPARTMENT CONNECTION (FDC). REFER TO CIVIL
DWGS.
1" = 40'-0" 1

FIRE ACCESS PLAN

1. WHERE A MEZZANINE OCCURS AND A 1" TOPPING IS

CALLED OUT FOR IN THE STRUCTURAL DRAWINGS,
PROVIDE A 1" THICK TOPPING OF GYP-CRETE 2000 WITH A
MINIMUM STRENGTH OF 2,500 PSI.

2. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE FIRE
DEPARTMENT AND THE CBC/CFC. REQUIREMENTS AND

LOCATIONS TO BE DETERMINED IN THE FIELD BY THE FIRE
DEPARTMENT INSPECTOR.

3. ALL PENETRATIONS THROUGH FIRE RATED PARTITIONS
SHALL BE SEALED WITH APPROVED FIRE CAULKING. SEE
SHTS AD2.3, & AD2.4.

4. U.O.N., ALL DIMENSIONS TO CONCRETE WALLS ARE EITHER

TO THE CENTER (SHOWN WITH A CENTERLINE) OR FACE OF
THE WALL. ALL DIMENSIONS TO FRAMED WALLS ARE

EITHER TO THE CENTER OF THE WALL FRAMING (SHOWN
WITH A CENTERLINE) OR FACE OF THE WALL FINISH.

5. PROVIDE ILLUMINATED AND TACTILE EXIT SIGNAGE. SEE
EXITING & SIGNAGE PLANS.

6. SEE CIVIL DRAWINGS FOR ALL UTILITY POINTS OF
CONNECTION. GENERAL CONTRACTOR TO VERIFY
LOCATIONS.

7. PROVIDE PIPE BOLLARD PROTECTION POSTS @ FIRE

RISERS & ELECTRICAL GEAR AS REQUIRED BY THE
ELECTRICAL AND FIRE PROTECTION PLANS. SEE 7/AD5.0
FOR ADDITIONAL INFORMATION.

8. FOR REQUIRED LANDINGS @ ALL INTERIOR & EXTERIOR
DOORS, SEE 11/A0.2.1.

9. NO SMOKING IS ALLOWED WITHIN 25' OF ALL BUILDING

ENTRANCES, PER GREEN BUILDING STANDARD CODE
DIVISION 5.504.7. POST REQUIRED SIGNAGE.

10. U.O.N @ INTERIOR PARTITIONS, FINISHED HINGE SIDE OF JAMB TO BE 6" FROM FINISHED SURFACE OF INTERSECTING
WALL.

EXTERIOR CONCRETE TILT-UP WALL PANEL

OR INTERIOR CONCRETE TILT-UP MEZZANINE
SHEAR WALL PANEL. SEE STRUCTURAL

DRAWINGS FOR ADDITIONAL INFORMATION
STOREFRONT GLAZING SYSTEM. SEE

ENLARGED FLOOR PLANS AND EXTERIOR

ELEVATIONS FOR ADDITIONAL INFORMATION
METAL STUD NON BEARING PARTITION WALL.

SEE ENLARGED FLOOR PLANS & WALL TYPE

SCHEDULE FOR ADDITIONAL INFORMATION

STRUCTURAL BUILDING COLUMNS
WOOD STUD BEARING WALL. SEE ENLARGED

FLOOR PLANS & WALL TYPE SCHEDULE FOR
ADDITIONAL INFORMATION.

PROVIDE VAPOR BARRIER UNDER

PROPOSED AND OR FUTURE OFFICE AREA
FLOOR SLAB. EXTEND MIN 40'-0" BEYOND
T.I. AREA OR AS DIMENSIONED ON THE
FLOOR PLAN. SEE 4/AD1.0
FIRE SPRINKLER RISER. SEE FIRE
PROTECTION PLANS AND 7/AD5.0.

DOOR TAG. SEE SHEET A8.0 FOR DOOR

SCHEDULE
WINDOW TAG. SEE SHEET A8.0 FOR

WINDOW SCHEDULE

WALL TAG
0000 A
STOREFRONT TAG. SEE SHEETS A8.0.1 &
A8.0.2 FOR STOREFRONT SCHEDULE
00 000

1. THE FLOOR SLAB THICKNESS TO BE X". SEE STRUCTURAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS.

2. THE FLOOR SLAB TO BE CLASS V PER ACI 302-1R-04 TABLE 21.

3. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE

OWNER WHETHER OR NOT TO PROVIDE JOINT FILLER AT
FLOOR SLAB CONTROL AND CONSTRUCTION JOINTS.

4. SLOPE POUR STRIPS @ EXTERIOR PEDESTRIAN AND
OVERHEAD DOORS. SEE 5, 7, & 10/AD4.1.

5. CRANES, CONCRETE TRUCKS, AND SIMILAR HEAVY

EQUIPMENT ARE PROHIBITED ON THE FLOOR SLAB DURING
CONSTRUCTION.

6. BELOW FLOOR SLAB SOIL COMPACTION TO BE 95% MIN.

7. TRENCH SOIL COMPACTION TO BE 90% MIN.

8. SLAB FINISH TO BE STEEL FLOAT HARD TROWEL BURNISHED
FINISH.

9. THE GENERAL CONTRACTOR TO MAINTAIN A CLEAN FLOOR
SLAB. ALL TRUCKS AND EQUIPMENT TO BE DIAPERED.

10. ALL CONSTRUCTION MARKINGS SHALL BE REMOVED FROM
THE FLOOR SLAB PRIOR TO SEALING.

11. SEE 6/AD2.1 FOR SLAB PATCHING DETAIL.

12. PROVIDE 10'-0" WIDE PERIMETER FLOOR POUR-STRIPS AT
ALL TRUCK DOCK WALLS AND 5'-0" WIDE AT ALL OTHER

WALLS UNLESS NOTED OTHERWISE ON STRUCTURAL
DRAWINGS. NO UNDERGROUND PIPING, CONDUITS, ETC

ALLOWED IN POUR-STRIPS AT DOCK DOORS TO ALLOW FOR
CURRENT OR FUTURE RECESSED DOCK LEVELERS.

13. ALL FLOOR SLAB NAIL OR BRACE FRAME HOLES TO BE FILLED WITH APPROVED 2-PART EPOXY COMPOUND TO MATCH
CONCRETE COLOR. PEGA BOND LV 2000, BURKE EPOXY
INJECTION RESIN OR =.

14. ALL FLOOR SLAB PANEL FORM NAIL HOLES TO BE
PREDRILLED AND WOOD DOWELED PRIOR TO NAILING.

BRACE HOLES TO BE PREDRILLED.

15. CHAMFER AND REVEAL STRIPS ATTACHED TO THE FLOOR

SLAB MUST BE PROPERLY PATCHED PRIOR TO SEALING THE
FLOOR SLAB.
12345
ABCDE
6 FGHIJK
66' - 0" 60' - 0" 60' - 0" 60' - 0" 59' - 0"
305' - 0"
116' - 0" +/- 189' - 0" +/-
540' - 0"
64' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 60' - 0" 3' - 8" 25' - 4" 30' - 0" 37' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 29' - 0" 23' - 0" 298' - 0"
66' - 0" 60' - 0" 60' - 0" 60' - 0" 52' - 0"
24' - 0" 24' - 0" 16' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 4' - 0" 30' - 0" 60' - 0" 416' - 0" 64' - 0"
540' - 0"
64' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 60' - 0" 26' - 0"
138 135 134 133 132 131 130 127 126 125 124 123 122 121 120 119 118 117 116 115 114 113 112 111 110 109 187 97 95
216
218 217
214 215 213 212 195
207 208
201
30' - 0" 30' - 0" 30' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 30' - 0" 30' - 0" 2000 SF
OFFICE
2000 SF MEZZ
1500 SF
FUTURE
OFFICE
1500 SF
FUTURE
OFFICE
2000 SF

FUTURE OFFICE
2000 SF MEZZ
2 A2_1
THIS ENTIRE WALL TO BE 3-HOUR FIRE RATED WITH 30" MIN. PARAPETS.

ALL PANEL JOINTS REQUIRE 3-HOUR CAULKING.

DOORS AND OPENINGS REQUIRE 3-HOUR RATING
THIS ENTIRE WALL TO BE 3-HOUR FIRE RATED WITH 30" MIN.

PARAPETS. ALL PANEL JOINTS REQUIRE 3-HOUR CAULKING.

DOORS AND OPENINGS REQUIRE 3-HOUR RATING THIS ENTIRE WALL TO BE 3-HOUR FIRE RATED WITH 30" MIN. PARAPETS. ALL PANEL JOINTS REQUIRE 3-HOUR CAULKING.

DOORS AND OPENINGS REQUIRE 3-HOUR RATING
56 GHIJ

LANDING
6' - 6"
RAMP
58' - 6" 6' - 0"
3' - 0"
59' - 0"
52' - 0"
1' - 9"
3' - 0"
5' - 9" 12' - 0" 5' - 6" 9' - 0" 4' - 0" 9' - 0" 2' - 0"2' - 0" 3' - 0"
2' - 6" 7' - 6" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 3' - 0"4' - 0"3' - 0" 3' - 0"
2' - 0"
150
95 138 135 134
91 133 132
52' - 0" 52' - 0"
401
NORTH

PROJECT
10/30/2025 4:34:23 PM
5TH PLANNING SUBMITTAL

09.04.2025

SANTEE, CA
A2_1
BUILDING 1

OVERALL PLAN PALISADE SANTEE COMMERCE CENTER PROJECT
10/30/2025 4:34:23 PM
5TH PLANNING SUBMITTAL

09.04.2025

SANTEE, CA
A2_1
BUILDING 1

OVERALL PLAN PALISADE SANTEE COMMERCE CENTER

KEYNOTES

FLOOR PLAN LEGEND

FLOOR PLAN GENERAL NOTES

FLOOR SLAB GENERAL NOTES
150 CONCRETE TRUCK RAMP w/ 42" HIGH CONCRETE TILT-UP
GUARD ON OPEN SIDE(S). PAINT ALL SIDES OF GUARD
WALLS AND HANDRAILS.SEE ARCHITECTURAL DRAWINGS

FOR COLOR SCHEDULE
201 STRUCTURAL BUILDING COLUMN
401 PAINTED CONCRETE TILT-UP WALL PANEL
1" = 30'-0"
1 PROPOSED BUILDING 1 FLOOR PLAN
1" = 10'-0"
2 PROPOSED BUILDING FLOOR PLAN - ENLARGED DOCK DOOR PLAN A

1. WHERE A MEZZANINE OCCURS AND A 1" TOPPING IS

CALLED OUT FOR IN THE STRUCTURAL DRAWINGS,
PROVIDE A 1" THICK TOPPING OF GYP-CRETE 2000 WITH A
MINIMUM STRENGTH OF 2,500 PSI.

2. PROVIDE FIRE EXTINGUISHERS AS REQUIRED BY THE FIRE
DEPARTMENT AND THE CBC/CFC. REQUIREMENTS AND

LOCATIONS TO BE DETERMINED IN THE FIELD BY THE FIRE
DEPARTMENT INSPECTOR.

3. ALL PENETRATIONS THROUGH FIRE RATED PARTITIONS
SHALL BE SEALED WITH APPROVED FIRE CAULKING. SEE
SHTS AD2.3, & AD2.4.

4. U.O.N., ALL DIMENSIONS TO CONCRETE WALLS ARE EITHER

TO THE CENTER (SHOWN WITH A CENTERLINE) OR FACE OF
THE WALL. ALL DIMENSIONS TO FRAMED WALLS ARE

EITHER TO THE CENTER OF THE WALL FRAMING (SHOWN
WITH A CENTERLINE) OR FACE OF THE WALL FINISH.

5. PROVIDE ILLUMINATED AND TACTILE EXIT SIGNAGE. SEE
EXITING & SIGNAGE PLANS.

6. SEE CIVIL DRAWINGS FOR ALL UTILITY POINTS OF
CONNECTION. GENERAL CONTRACTOR TO VERIFY
LOCATIONS.

7. PROVIDE PIPE BOLLARD PROTECTION POSTS @ FIRE

RISERS & ELECTRICAL GEAR AS REQUIRED BY THE
ELECTRICAL AND FIRE PROTECTION PLANS. SEE 7/AD5.0
FOR ADDITIONAL INFORMATION.

8. FOR REQUIRED LANDINGS @ ALL INTERIOR & EXTERIOR
DOORS, SEE 11/A0.2.1.

9. NO SMOKING IS ALLOWED WITHIN 25' OF ALL BUILDING

ENTRANCES, PER GREEN BUILDING STANDARD CODE
DIVISION 5.504.7. POST REQUIRED SIGNAGE.

10. U.O.N @ INTERIOR PARTITIONS, FINISHED HINGE SIDE OF JAMB TO BE 6" FROM FINISHED SURFACE OF INTERSECTING
WALL.

EXTERIOR CONCRETE TILT-UP WALL PANEL

OR INTERIOR CONCRETE TILT-UP MEZZANINE
SHEAR WALL PANEL. SEE STRUCTURAL

DRAWINGS FOR ADDITIONAL INFORMATION
STOREFRONT GLAZING SYSTEM. SEE

ENLARGED FLOOR PLANS AND EXTERIOR

ELEVATIONS FOR ADDITIONAL INFORMATION
METAL STUD NON BEARING PARTITION WALL.

SEE ENLARGED FLOOR PLANS & WALL TYPE

SCHEDULE FOR ADDITIONAL INFORMATION

STRUCTURAL BUILDING COLUMNS
WOOD STUD BEARING WALL. SEE ENLARGED

FLOOR PLANS & WALL TYPE SCHEDULE FOR
ADDITIONAL INFORMATION.

PROVIDE VAPOR BARRIER UNDER

PROPOSED AND OR FUTURE OFFICE AREA
FLOOR SLAB. EXTEND MIN 40'-0" BEYOND
T.I. AREA OR AS DIMENSIONED ON THE
FLOOR PLAN. SEE 4/AD1.0
FIRE SPRINKLER RISER. SEE FIRE
PROTECTION PLANS AND 7/AD5.0.

DOOR TAG. SEE SHEET A8.0 FOR DOOR

SCHEDULE
WINDOW TAG. SEE SHEET A8.0 FOR

WINDOW SCHEDULE

WALL TAG
0000 A
STOREFRONT TAG. SEE SHEETS A8.0.1 &
A8.0.2 FOR STOREFRONT SCHEDULE
00 000

1. THE FLOOR SLAB THICKNESS TO BE X". SEE STRUCTURAL
DRAWINGS FOR ADDITIONAL REQUIREMENTS.

2. THE FLOOR SLAB TO BE CLASS V PER ACI 302-1R-04 TABLE 21.

3. THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE

OWNER WHETHER OR NOT TO PROVIDE JOINT FILLER AT
FLOOR SLAB CONTROL AND CONSTRUCTION JOINTS.

4. SLOPE POUR STRIPS @ EXTERIOR PEDESTRIAN AND
OVERHEAD DOORS. SEE 5, 7, & 10/AD4.1.

5. CRANES, CONCRETE TRUCKS, AND SIMILAR HEAVY

EQUIPMENT ARE PROHIBITED ON THE FLOOR SLAB DURING
CONSTRUCTION.

6. BELOW FLOOR SLAB SOIL COMPACTION TO BE 95% MIN.

7. TRENCH SOIL COMPACTION TO BE 90% MIN.

8. SLAB FINISH TO BE STEEL FLOAT HARD TROWEL BURNISHED
FINISH.

9. THE GENERAL CONTRACTOR TO MAINTAIN A CLEAN FLOOR
SLAB. ALL TRUCKS AND EQUIPMENT TO BE DIAPERED.

10. ALL CONSTRUCTION MARKINGS SHALL BE REMOVED FROM
THE FLOOR SLAB PRIOR TO SEALING.

11. SEE 6/AD2.1 FOR SLAB PATCHING DETAIL.

12. PROVIDE 10'-0" WIDE PERIMETER FLOOR POUR-STRIPS AT
ALL TRUCK DOCK WALLS AND 5'-0" WIDE AT ALL OTHER

WALLS UNLESS NOTED OTHERWISE ON STRUCTURAL
DRAWINGS. NO UNDERGROUND PIPING, CONDUITS, ETC

ALLOWED IN POUR-STRIPS AT DOCK DOORS TO ALLOW FOR
CURRENT OR FUTURE RECESSED DOCK LEVELERS.

13. ALL FLOOR SLAB NAIL OR BRACE FRAME HOLES TO BE FILLED WITH APPROVED 2-PART EPOXY COMPOUND TO MATCH
CONCRETE COLOR. PEGA BOND LV 2000, BURKE EPOXY
INJECTION RESIN OR =.

14. ALL FLOOR SLAB PANEL FORM NAIL HOLES TO BE
PREDRILLED AND WOOD DOWELED PRIOR TO NAILING.

BRACE HOLES TO BE PREDRILLED.

15. CHAMFER AND REVEAL STRIPS ATTACHED TO THE FLOOR

SLAB MUST BE PROPERLY PATCHED PRIOR TO SEALING THE
FLOOR SLAB.
789 10 11 12

LMNOPQSTVK
124' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 52' - 0" 72' - 0" 2' - 0" 43' - 2" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 24' - 0" 59' - 0" 60' - 0" 60' - 0" 60' - 0" 67' - 0"
189' - 0" 117' - 0"
30' - 0" 29' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 10' - 0" 10' - 0"
26' - 0" 26' - 0" 25' - 0" 27' - 2" 2' - 0"
20' - 0" 26' - 0" 26' - 0" 25' - 9" 26' - 3" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 26' - 0" 27' - 0" 27' - 0" 54' - 0"488' - 0"
560' - 0"
23' - 0" 29' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 30' - 0" 7' - 0" 30' - 0" 27' - 2" 2' - 0" 10"
18' - 0"
52' - 0" 60' - 0" 60' - 0" 60' - 0"
218
206 209 210
216 215 213 214
222
98 187 182 181 180 179 178 177 176
185
175 174 173 172 171 170 169 168
183
167 166 165 163 162 161 160 159
184
158 157 149
96 45' - 2" 2' - 0"
201
R
2000 SF
OFFICE
2000 SF MEZZ
2000 SF
OFFICE
2000 SF MEZZ
1500 SF

POTENTIAL
OFFICE
1500 SF

POTENTIAL
OFFICE
2 A2_2
78 QST
2' - 7" 3' - 0" 5' - 9" 12' - 0"
3' - 3"
2' - 3" 9' - 0" 4' - 0" 9' - 0" 4' - 0"3' - 0"3' - 0"4' - 0"3' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 4' - 0" 9' - 0" 3' - 0"4' - 0" 3' - 0" 3' - 0"
23' - 0" 29' - 0"
96 149 157 158
184
159 160
59' - 0"
401
161 162 163 165 166 167
183
R
52' - 0" 52' - 0" 52' - 0"
NORTH

PROJECT
10/30/2025 4:38:21 PM
5TH PLANNING SUBMITTAL
A22-2164

SANTEE, CA

09.04.2025
A2_2
BUILDING 2

OVERALL PLAN PALISADE SANTEE COMMERCE CENTER PROJECT
10/30/2025 4:38:21 PM
5TH PLANNING SUBMITTAL
A22-2164

SANTEE, CA

09.04.2025
A2_2
BUILDING 2

OVERALL PLAN PALISADE SANTEE COMMERCE CENTER

KEYNOTES

FLOOR PLAN LEGEND

FLOOR PLAN GENERAL NOTES

FLOOR SLAB GENERAL NOTES
201 STRUCTURAL BUILDING COLUMN
401 PAINTED CONCRETE TILT-UP WALL PANEL
1" = 30'-0"
1 PROPOSED BUILDING 2 FLOOR PLAN
1" = 10'-0"
2 PROPOSED BUILDING FLOOR PLAN - ENLARGED DOCK DOOR PLAN B

FINISH FLOOR
0"

MEZZANINE
15' - 0"

KJ I HGFEDCBA
50'-0" MAX HEIGHT

FINISH FLOOR
0"

MEZZANINE
15' - 0"
123456
50'-0" MAX HEIGHT.

FINISH FLOOR
0"

MEZZANINE
15' - 0"

ABCDEFGH I JK
50'-0" MAX HEIGHT

FINISH FLOOR
0"

MEZZANINE
15' - 0"
654321
404 402
50'-0" MAX HEIGHT
NOTES:

1. ALL IMPERFECTIONS ON THE SURFACE OF THE CONCRETE

WALL PANELS SHALL BE PATCHED / SACKED / SANDED

SMOOTH PRIOR TO PAINTING REGARDLESS IF COVERED BY
SPANDREL GLAZING.

2. ALL INTERIOR AND EXTERIOR FABRICATED STEEL SHALL BE

SHOP PRIMED WITH A GRAY, RUST INHIBITIVE PRIMER
PRIOR TO DELIVERY TO THE JOB SITE. ANY AND ALL

DAMAGE TO THE PRIMER COAT SHALL BE TOUCHED UP

PRIOR TO ADDITIONAL FINAL COLOR PAINTING OR
COMPLETION OF THE PROJECT.

3. PAINT MAN DOORS, STAIR & RAMP GUARD WALLS, GUARD

RAILS, DOWN SPOUTS, LOUVERS, & ROOF LEVEL WALL

PANEL RETURNS TO MATCH ADJACENT BUILDING WALL
COLOR, U.O.N.

4. U.O.N., EXTERIOR SIDE OF TRUCK DOORS TO MATCH
ADJACENT WALL COLOR.

5. POWER WASH EXTERIOR CONCRETE WALLS PRIOR TO

PAINTING TO REMOVE ALL CHEMICALS AND DIRT THAT WILL

IMPEDE THE PRIMER COAT FROM ADHERING TO THE
WALLS.

6. PAINT EXTERIOR WALLS w/ 1- COAT SPRAYED AND BACK
ROLLED ACRYLIC FLAT PRIMER AND 2-COATS SPRAYED-ON
FLAT FINISH IN THE FINAL WALL COLOR. FINISHED JOB

SHALL BE SMOOTH AND FREE OF LAPPING AND OR
STREAKING, REGARDLESS OF THE COLOR.

7. EXCEPT WHERE NOTED OTHERWISE ON THE PLANS ALL
PANEL JOINTS SHALL BE CAULKED PER DETAIL 1/AD4.1.

8. PAINT CONCRETE BEHIND ANY OPEN TRELLIS WORK THE
COLOR OF THE TRELLIS.

9. @ SOLID BROWS WITH GLAZING DIRECTLY ABOVE OR

BELOW, PAINT THE EXPOSED WALL CHAMFER JUST ABOVE
OR BELOW THE BROW TO MATCH THE BROW COLOR.

10. PAINT ALL WALL REVEALS THE COLOR OF THE ADJACENT
WALL. WHEN THERE IS A COLOR CHANGE AT THE REVEAL,
SEE 2/AD4.1

11. U.O.N., PAINT THE SIDE OPPOSITE THE SIDE SHOWN OF
SCREEN WALLS THE SAME COLOR AS THE SIDE SHOWN. IF
THERE ARE TWO COLORS SHOWN, USE THE BASE COLOR.

12. ALL PAINTS USED SHALL BE AS SPECIFIED BY THE

MANUFACTURER FOR THE PROPOSED USE

13. PAINT COLOR FOR EXPOSED STEEL BROW & CANOPY
FRAMING, WALL BEHIND OPEN TRELLIS (KEY NOTE 428, OR
429) WHEN OCCURS & TRASH ENCLOSURE METAL ROOF,

ROOF BEAMS, & SUPPORT COLUMNS TO MATCH
STOREFRONT FRAMING.

14. REFER TO DIGITAL COPY OF PLANS FOR RENDERING AND
ELEVATION IN COLOR. HARDCOPY PLANS WILL SHOW
BLACK AND WHITE ONLY. A
WHITE EXTERIOR PAINT COLOR:

SW 7005 PURE WHITE
B
LIGHT GRAY EXTERIOR PAINT COLOR:

SW 6233 SAMOVAR SILVER
C
MEDIUM GRAY EXTERIOR PAINT COLOR:

SW 9152 LET IT RAIN

E METAL PANEL DRI-DESIGN
D

STOREFRONT GLAZING COLOR
EXTERIOR LAYER: MEDIUM PERFORMANCE

BLUE REFLECTIVE GLAZING
F

CHARCOAL ANODIZED METAL

EYEBROW/CANOPY
NOTES:

1. FOR GLASS AND MULLION COLORS, SEE EXTERIOR
COLORS, LEGEND & NOTES, THIS SHEET.

2. PROVIDE TEMPERED GLASS @ ALL LOCATIONS.

3. @ SPANDREL SYSTEM GLAZING IN FRONT OF CONCRETE
WALL PANELS, PROVIDE 1" DIA. VENTILLATION HOLES IN
THE CONCRETE A MAX OF 5'-0" O.C. CONTRACTOR TO

PROVIDE A SMOOTH FINISH ON THE GLASS FACING

CONCRETE SURFACES AND TO PAINT THEM & ALL

STOREFRONT FRAMES AND CLIPS BEHIND THE GLASS
BLACK.

4. @ SPANDREL SYSTEM GLAZING NOT IN FRONT OF A
CONCRETE WALL PANEL, PROVIDE TENCATE MIRAFI 140N
FILTER FABRIC SHADE CLOTH.

STOREFRONT FRAMING:

U.O.N @ VISION SYSTEM, MIN 2"x4 1/2" OFFSET
SYSTEM. U.O.N. @ SPANDREL SYSTEM, 2"x1 3/4"
OFFSET SYSTEM. STOREFRONT SYSTEM TO BE
DESIGN BUILD BY THE GENERAL CONTRACTOR.

DESIGN SHALL COMPLY WITH ALL RELEVANT CODE
& WIND LOADING REQUIREMENTS.

VISION SYSTEM GLAZING:

FOR EXTERIOR VISION GLAZING USE 1" INSULATED
GLASS CONSISTING OF AN OUTER LAYER OF 1/4"
VISTACOOL AND AN INNER LAYER OF 1/4"
SOLARBAN 60. FOR INTERIOR GLAZING USE 1/2"
CLEAR GLASS.

SPANDREL SYSTEM GLAZING:

FOR EXTERIOR SPANDREL GLAZING USE 1/4"

GLASS TO MATCH EXTERIOR GLASS COLOR ON
COLOR LEGEND. IF SPANDREL COATING IS NOT

SPECIFIED, PROVIDE PHYSICAL SAMPLES FOR
ARCHITECT'S APPROVAL.

PROJECT
10/30/2025 4:34:32 PM
5TH PLANNING SUBMITTAL

09.04.2025

SANTEE, CA
A4_1
BUILDING 1

EXTERIOR

ELEVATIONS

PALISADE SANTEE COMMERCE CENTER
1" = 20'-0"
1 BUILDING 1 EAST ELEVATION
1" = 20'-0"
2 BUILDING 1 SOUTH ELEVATION
1" = 20'-0"
3 BUILDING 1 WEST ELEVATION
1" = 20'-0"
4 BUILDING 1 NORTH ELEVATION

KEYNOTES

GLAZING LEGEND & NOTES

EXTERIOR WALL COLOR LEGEND & NOTES
402 WALL REVEAL
404 PANEL JOINT

FINISH FLOOR
0"

MEZZANINE
15' - 0"

VRTSQPONMLK
50'-0" MAX HEIGHT

FINISH FLOOR
0"

MEZZANINE
15' - 0"
12 11 10987
50'-0" MAX HEIGHT

FINISH FLOOR
0"

MEZZANINE
15' - 0"

LMNOPQSTRV
50'-0" MAX HEIGHT

FINISH FLOOR
0"

MEZZANINE
15' - 0"
789 10 11 12
404 402
50'-0" MAX HEIGHT.

NOTES:

1. ALL IMPERFECTIONS ON THE SURFACE OF THE CONCRETE

WALL PANELS SHALL BE PATCHED / SACKED / SANDED

SMOOTH PRIOR TO PAINTING REGARDLESS IF COVERED BY
SPANDREL GLAZING.

2. ALL INTERIOR AND EXTERIOR FABRICATED STEEL SHALL BE

SHOP PRIMED WITH A GRAY, RUST INHIBITIVE PRIMER
PRIOR TO DELIVERY TO THE JOB SITE. ANY AND ALL

DAMAGE TO THE PRIMER COAT SHALL BE TOUCHED UP

PRIOR TO ADDITIONAL FINAL COLOR PAINTING OR
COMPLETION OF THE PROJECT.

3. PAINT MAN DOORS, STAIR & RAMP GUARD WALLS, GUARD

RAILS, DOWN SPOUTS, LOUVERS, & ROOF LEVEL WALL

PANEL RETURNS TO MATCH ADJACENT BUILDING WALL
COLOR, U.O.N.

4. U.O.N., EXTERIOR SIDE OF TRUCK DOORS TO MATCH
ADJACENT WALL COLOR.

5. POWER WASH EXTERIOR CONCRETE WALLS PRIOR TO

PAINTING TO REMOVE ALL CHEMICALS AND DIRT THAT WILL

IMPEDE THE PRIMER COAT FROM ADHERING TO THE
WALLS.

6. PAINT EXTERIOR WALLS w/ 1- COAT SPRAYED AND BACK
ROLLED ACRYLIC FLAT PRIMER AND 2-COATS SPRAYED-ON
FLAT FINISH IN THE FINAL WALL COLOR. FINISHED JOB

SHALL BE SMOOTH AND FREE OF LAPPING AND OR
STREAKING, REGARDLESS OF THE COLOR.

7. EXCEPT WHERE NOTED OTHERWISE ON THE PLANS ALL
PANEL JOINTS SHALL BE CAULKED PER DETAIL 1/AD4.1.

8. PAINT CONCRETE BEHIND ANY OPEN TRELLIS WORK THE
COLOR OF THE TRELLIS.

9. @ SOLID BROWS WITH GLAZING DIRECTLY ABOVE OR

BELOW, PAINT THE EXPOSED WALL CHAMFER JUST ABOVE
OR BELOW THE BROW TO MATCH THE BROW COLOR.

10. PAINT ALL WALL REVEALS THE COLOR OF THE ADJACENT
WALL. WHEN THERE IS A COLOR CHANGE AT THE REVEAL,
SEE 2/AD4.1

11. U.O.N., PAINT THE SIDE OPPOSITE THE SIDE SHOWN OF
SCREEN WALLS THE SAME COLOR AS THE SIDE SHOWN. IF
THERE ARE TWO COLORS SHOWN, USE THE BASE COLOR.

12. ALL PAINTS USED SHALL BE AS SPECIFIED BY THE

MANUFACTURER FOR THE PROPOSED USE

13. PAINT COLOR FOR EXPOSED STEEL BROW & CANOPY
FRAMING, WALL BEHIND OPEN TRELLIS (KEY NOTE 428, OR
429) WHEN OCCURS & TRASH ENCLOSURE METAL ROOF,

ROOF BEAMS, & SUPPORT COLUMNS TO MATCH
STOREFRONT FRAMING.

14. REFER TO DIGITAL COPY OF PLANS FOR RENDERING AND
ELEVATION IN COLOR. HARDCOPY PLANS WILL SHOW
BLACK AND WHITE ONLY. A
WHITE EXTERIOR PAINT COLOR:

SW 6995 SUPER WHITE
B
LIGHT GRAY EXTERIOR PAINT COLOR:

SW 7666 FLEUR DE SEL
C
MEDIUM GRAY EXTERIOR PAINT COLOR:

SW 7674 PEPPERCORN

E METAL PANEL DRI-DESIGN
D

STOREFRONT GLAZING COLOR
EXTERIOR LAYER: MEDIUM PERFORMANCE

BLUE REFLECTIVE GLAZING
F

CHARCOAL ANODIZED METAL

EYEBROW/CANOPY
NOTES:

1. FOR GLASS AND MULLION COLORS, SEE EXTERIOR
COLORS, LEGEND & NOTES, THIS SHEET.

2. PROVIDE TEMPERED GLASS @ ALL LOCATIONS.

3. @ SPANDREL SYSTEM GLAZING IN FRONT OF CONCRETE
WALL PANELS, PROVIDE 1" DIA. VENTILLATION HOLES IN
THE CONCRETE A MAX OF 5'-0" O.C. CONTRACTOR TO

PROVIDE A SMOOTH FINISH ON THE GLASS FACING

CONCRETE SURFACES AND TO PAINT THEM & ALL

STOREFRONT FRAMES AND CLIPS BEHIND THE GLASS
BLACK.

4. @ SPANDREL SYSTEM GLAZING NOT IN FRONT OF A
CONCRETE WALL PANEL, PROVIDE TENCATE MIRAFI 140N
FILTER FABRIC SHADE CLOTH.

STOREFRONT FRAMING:

U.O.N @ VISION SYSTEM, MIN 2"x4 1/2" OFFSET
SYSTEM. U.O.N. @ SPANDREL SYSTEM, 2"x1 3/4"
OFFSET SYSTEM. STOREFRONT SYSTEM TO BE
DESIGN BUILD BY THE GENERAL CONTRACTOR.

DESIGN SHALL COMPLY WITH ALL RELEVANT CODE
& WIND LOADING REQUIREMENTS.

VISION SYSTEM GLAZING:

FOR EXTERIOR VISION GLAZING USE 1" INSULATED
GLASS CONSISTING OF AN OUTER LAYER OF 1/4"
VISTACOOL AND AN INNER LAYER OF 1/4"
SOLARBAN 60. FOR INTERIOR GLAZING USE 1/2"
CLEAR GLASS.

SPANDREL SYSTEM GLAZING:

FOR EXTERIOR SPANDREL GLAZING USE 1/4"

GLASS TO MATCH EXTERIOR GLASS COLOR ON
COLOR LEGEND. IF SPANDREL COATING IS NOT

SPECIFIED, PROVIDE PHYSICAL SAMPLES FOR
ARCHITECT'S APPROVAL.

PROJECT
10/30/2025 4:38:33 PM
5TH PLANNING SUBMITTAL
A22-2164

SANTEE, CA

09.04.2025
A4_2

EXTERIOR

ELEVATIONS

PALISADE SANTEE COMMERCE CENTER
1" = 20'-0"
1 BUILDING 2 EAST ELEVATION
1" = 20'-0"
2 BUILDING 2 NORTH ELEVATION
1" = 20'-0"
3 BUILDING 2 WEST ELEVATION
1" = 20'-0"
4 BUILDING 2 SOUTH ELEVATION

KEYNOTES

GLAZING LEGEND & NOTES

EXTERIOR WALL COLOR LEGEND & NOTES
402 WALL REVEAL
404 PANEL JOINT
NORTH

PROJECT
10/30/2025 4:38:35 PM
5TH PLANNING SUBMITTAL
A22-2164

SANTEE, CA

09.04.2025
A5

COLOR BOARD PALISADE SANTEE COMMERCE CENTER
2" SQ STEEL

HORIZONTAL
1" SQ STEEL VERTICALS
@ 6" O.C. TYP.
4" SQ STEEL POSTS @ 8'-0"
O.C. MAX
CAP. MATCH FENCE

COLOR, TYP
2" SQ STEEL

HORIZONTAL
CONCRETE FOOTING 1"
ABOVE ADJACENT GRADE.

SLOPE TOP AWAY FROM
POST

SEE SITE PLAN
MAX
4".
6" 6"
NOTES:

1. MEMBER SIZES SHOWN ARE MINIMUM. ENTIRE FENCE ASSEMBLY TO BE DESIGN BUILD. MUST BE DESIGNED TO LOCAL JURISDICTION WIND LOADING REQUIREMENTS

2. ALL STEEL FENCE MATERIALS TO BE PRE GALVANIZED AND POWDER COATED BLACK
1' - 6" CENTERED ON GATE TRACK
2'-0".

SITE PAVING PER PLAN
2 x 2 x1/4 CONT STEEL ANGLE
TRACK w/ 5/8" x 6" STUD
ANCHORS @ 24" O.C. ADD

ADDITIONAL ANGLE TRACK
AND WIDEN FOOTING @
TELESCOPING GATES.

CONFIRM REQUIREMENTS w/
GATE FABRICATOR.

CONT CONCRETE FTNG w/ 6"
WIDE x DEPTH OF GATE

TRACK ANGLE RECESS

TOP RAIL

END POST

TRUSS ROD WHERE

REQUIRED

BOTTOM TENSION
WIRE
INTERMEDIATE POST.

SPACING / DESIGN

BUILD CONTRACTOR

FINISH GRADE OR

TOP OF PAVING

CONCRETE

FOOTING

SEE SITE PLAN
4" MAX
2" 9GA CHAIN LINK
FABRIC
NOTES:

1. ENTIRE FENCING ASSEMBLY TO BE DESIGN BUILD AND MUST BE DESIGNED TO LOCAL JURISDICTION WIND LOADING REQUIREMENTS.

2. ALL STEEL FENCE MATERIALS TO BE GALVANIZED U.N.O. ON SITE PLANS

FACE OF SCREEN WALL OR TUBE
STEEL FENCE. SEE SITE PLAN

ROLLER GUIDE ASSEMBLY

HSS SUPPORT FRAME WITH
FOOTING @ BOTT (NOT SHOWN)
& CONNECTION BACK TO

SCREEN WALL OR TUBE STEEL
FENCE @ TOP

ROLLING GATE
. .

MAINTAIN MIN 2 1/4" CLR BTWN

GATE FRAME AND SUPPORT

FRAME AND SCREEN WALL OR

TUBE STEEL FENCE

ADJACENT PAVING OR
LANDSCAPING. SEE SITE PLAN
12 AD1.1
GATE
TRACK

SEE SITE PLAN
NOTES:

1. ENTIRE GATE

SUPPORT FRAME

ASSEMBLY TO BE
DESIGN BUILD. MUST

BE DESIGNED TO

LOCAL JURISDICTION

WIND LOADING

REQUIREMENTS

2. GATE FRAME

SUPPORT ASSEMBLY

TO BE PAINTED TO

MATCH GATE

ROLLING GATE
1" SQUARE HSS
PICKETS @ 6" O.C.

SELF ADJUSTING
WHEEL ASSEMBLY w/
ROLLER COVERS, 2

PER GATE LEAF

HSS GATE
FRAME

GATE ELEVATION

CONCRETE SCREEN

WALL OR TUBE STEEL
FENCING. SEE PLAN

SUPPORT BRACKET,
TYP. SEE 15/AD1.1
@ OPPOSING DBLE

GATES - RECEIVER

GUIDE MOUNTED TO
ONE GATE PANEL.

CROSS SECTIONAL

AREA OF EACH

LEADING EDGE TO
BE MIN 9 SQUARE
INCHES
GATE NOTES:

1. THE GATES SHALL BE DESIGNED, CONSTRUCTED, AND

INSTALLED TO BE EITHER MOTORIZED AT THE TIME OF
INSTALLATION (CONFIRM w/ OWNER OR BUILDING

DEPARTMENT) OR TO BE CAPABLE OF BEING MOTORIZED AT A
FUTURE DATE. GATES SHALL COMPLY w/ ALL RELEVANT
REQUIREMENTS OF ASTM F2200 (CBC 3110.3). OMIT
PERFORATED STEEL COVERING (NOTE 6 BELOW) IF NOT

REQUIRED BY PLANNING AND IF OPERATORS ARE NOT BEING
INSTALLED AS PART OF THIS SCOPE. IF OPERATORS ARE
BEING INSTALLED THEY MUST COMPLY WITH UL 325

2. GATE ASSEMBLY TO BE FULLY WELDED & PREFINISHED,
COLOR BY ARCHITECT.

3. ENTIRE GATE ASSEMBLY TO BE DESIGN BUILD . MUST BE

DESIGNED TO LOCAL JURISDICTION WIND LOADING
REQUIREMENTS.

4. TOP OF GATE TO BE LEVEL IN CLOSED POSITION. SLOPE
BOTTOM AS REQUIRED.

5. PROVIDE CONT CONCRETE FOOTING WITH STEEL ANGLE
GATE TRACK. SEE 12/AD1.1

6. PROVIDE PAINTED 65% OPEN PERFORATED STEEL
COVERING OVER ENTIRE GATE.

7. GATES SHALL BE DESIGNED TO NOT BE MOVEABLE WHEN
DISCONNECTED FROM THE CURRENT OR FUTURE OPERATOR.

8. POSITIVE STOPS SHALL BE INSTALLED ON TOP OF GATE FOR BOTH FULLY OPEN AND FULLY CLOSED POSITIONS.

9. @ SINGLE OR TELESCOPING GATES, RECEIVER GUIDES
LESS THAN 8' ABOVE GRADE TO BE RECESSED BEHIND GATE
POSTS.

10. VEHICULAR GATES IF MOTORIZED SHALL HAVE A MINIMUM
OF TWO (2) EASILY VISIBLE WARNING SIGNS INSTALLED ON
EACH SIDE OF THE GATE MEETING WITH ANSI Z535. LAYOUT
TO COMPLY WITH UL 325 (CBC 3110.4)

11. GATES SHALL BE DESIGNED, CONSTRUCTED, AND

INSTALLED SUCH THAT THEIR MOVEMENT SHALL NOT BE

INITIATED BY GRAVITY WHEN DISCONNECTED FROM AN

AUTOMATIC OPERATOR & SHALL NOT FALL OVER MORE THAN
45 DEGREES FROM THE VERTICAL PLANE WHEN DETACHED
FROM SUPPORTING HARDWARE.
8" 4' - 0"

SUPPORT
BRACKET, TYP. SEE
15/AD1.1

GATE PLAN
12". SEE SITE PLAN FOR OPENING 12". 4'-0". 8"

SEE SITE PLAN
1' - 0"
1' - 0"
@ HANDRAIL - ALL MEMBERS TO BE PAINTED 1 1/2" STD PIPE.

ALL RADII SHOWN AT BENDS TO BE 3" OUTSIDE. PROVIDE

VERTICAL POSTS AT EA END AS SHOWN AND INTERMEDIATE
POSTS AS REQUIRED. INTERMEDIATE POSTS TO BE SPACED
EVENLY, MAX 4'-0" O.C. @ VERTICAL POSTS, DRILL HOLE @
CENTERLINE OF CURB, 1" LARGER THAN RAIL POST, 6" DEEP
AND INSERT POST. FILL w/ NON SHRINK GROUT. F'c 3500 PSI MIN

RAMP/SIDEWALK

SECTION PER
1/AD1.0 (OR
STRUCTURAL @

SOME CONDITIONS,

SEE PLAN)
1' - 3" 6" 6" 1'-3".
6" HIGH x 8" WIDE

CONT CONC CURB
POURED
MONOLITHICALLY w/
RAMP w/ (2) #4 BARS
CONT.
38" MAX
34" MIN
1/2". 1' - 0 3/256"
1".

MIN MIN
1" 3" MIN

STOREFRONT /PLAN
ROD & CAULK o/

COMPRESSIBLE MATERIAL
CONCRETE MOW STRIP.

SLOPE AWAY FROM
BUILDING @ 2%. EXTEND
12" BEYOND EA END OF
THE STOREFRONT. OMIT

WHERE THE SILL IS
MORE THAN 3' ABOVE
ADJACENT GRADE.

COMPACTED SUB

GRADE PER SOILS
REPORT
3/8" x 10" SQ STEEL BASE PL
6" Ø STANDARD STEEL PIPE SCHEDULE
40 PAINTED SAFETY YELLOW, FILLED w/
CONCRETE w/ ROUNDED TOP
18" DIA
6" 4'-0". 4'-0" U.O.N.

SLOPE TOP OF CONCRETE 1/2"
AWAY FROM POST. @ EXT.

CONDITIONS ONLY
T.O.PAVING @ EXTERIOR
CONDITIONS. T.O.SLAB @ INTERIOR

CONDITIONS

CONCRETE FOOTING
NOTES: 1/4"

1. PIPE FILLER AND FOOTING
CONCRETE TO BE 3000PSI w/
3/8" AGGREGATE

PLAN VIEW

SECTION
2' - 6"
6".

MIN
12". 4' - 0"
MIN
6".
5" MIN
6" MAX

FACE OF BUILDING, SITE

WALL, OR CURB

CENTER OF STALL

STRIPING

PRECAST CONCRETE
WHEEL STOP. MAY

OCCUR ON OPP SIDE OF
STALL. SEE SITE PLAN
3/4" DIA x 24" G.I. PIPE
STAKE

PRECAST

CONCRETE WHEEL
STOP
T.O.PAVING
3/4" DIA x 24" G.I.

PIPE STAKE
18 AD1.1

CONCRETE SCREEN WALL

ROLLING GATE
ASSEMBLY. SEE 13/AD1.1

TYP EA SIDE OF RAMP,

HANDRAIL MOUNTED ON
CONT CONCRETE CURB.

SEE 1/AD1.1
DRIVE-THRU RAMP.

SEE STRUCTURAL
FOR

REQUIREMENTS

SEE PLAN SEE PLAN
SITE

PAVING/
PLAN

ACCESSIBLE

PEDESTRIAN RAMP
6" 5' - 6"
MIN L3x3x1/4 FRAME

TRASH ENCLOSURE WALL
(STEEL POST @ SOME
CONDITIONS. SEE PLAN)
HEAVY DUTY BUTT HINGE.

MIN 3 PER GATE. SEE
11/AD1.1
1 1/2" x 22GA STEEL DECK

DIAGONAL BRACE ON BACK

SIDE OF GATE

TOP OF CONCRETE PAVING

SLIDE BOLT
NOTES:

1. ENTIRE GATE ASSEMBLY TO BE DESIGN BUILD . MUST BE DESIGNED

TO LOCAL JURISDICTION WIND LOADING REQUIREMENTS

2. ENTIRE GATE ASSEMBLY TO BE PAINTED. COLOR BY ARCHITECT.

SEE TRASH ENCLOSURE PLANS
3/4" DIA CANE BOLT w/ STEEL

SLEEVE INTO CONRETE
SLAB
STEEL L JAMB CAST INTO WALL.

SEE STRUCTURAL

HEAVY DUTY BUTT HINGE

STEEL DECKING

STEEL L GATE FRAME

DIAGONAL BRACING

TRASH ENCLOSURE WALL
SEESEE PLAN6"
PLAN
AD1.1
9 CONCRETE SCREEN WALL PANEL
HEIGHT OF GATE HSS 2"x4" JAMB EA SIDE

FASTENED TO CONCRETE WALL PANEL
TUBE STEEL GATE. HSS 2"x2" TOP &
SIDES & HSS 2"x4" BOTTOM FRAME w/
HSS 1"x1" PICKETS @ 6" O.C. PROVIDE
HINGES AS REQUIRED. GATE TO
PROVIDE MIN 32" CLR OPNG WHEN OPEN
90 DEGREES
NOTES:

1. ENTIRE GATE ASSEMBLY TO BE DESIGN
BUILD. MUST BE DESIGNED TO LOCAL

JURISDICTION WIND LOADING
REQUIREMENTS.

2. ENTIRE GATE ASSEMBLY TO BE
PAINTED. COLOR BY ARCHITECT.

3. PROVIDE KNOX BOX PER FIRE
DEPARTMENT REQUIREMENTS.

4. WHEN GATE IS ADJACENT TO

VEHICULAR GATES PROVIDE PAINTED

PERFORATED STEEL COVERING TO
MATCH.

GATE HARDWARE - GROUP 22 ON SHT
A8.0. HARDWARE SCHEDULE. MUST

COMPLY WITH THE DOOR NOTES ON
SHT A8.0.

FINISHED SURFACE

UNINTERRUPTED
10" SMOOTH &

SEE PLAN
34" MIN, 44" MAX

MOUNTING PLATE
EQ EQ

SEE PLAN

CONCRETE SCREEN

WALL PANEL
HSS 2"x4" JAMB EA SIDE OF

GATE FASTENED TO

CONCRETE SCREEN WALL
PANEL. TUBE STEEL
FENCE POST @ TUBE

STEEL FENCE CONDITION

STEEL HINGE
HSS 2"x2" GATE FRAME
HSS 1"x1" PICKET
18 AD1.1

BUILDING WALL

WALL MOUNTED
HANDRAIL. SEE 16/AD.1

ACCESSIBLE
PEDESTRIAN RAMP.

DRIVE-THRU RAMP.

SEE STRUCTURAL
FOR

REQUIREMENTS

HANDRAIL MOUNTED

ON CONT CONCRETE
CURB. SEE 1/AD1.1

BUILDING SLAB

SEE PLAN
PROVIDE 1/2" GAP. FILL w/
COMPRESSIBLE MATERIAL. ROD
& CAULK ON TOP
SIM
MIN
8"
MIN
6"
8" 8"
12" MIN
6" MIN
6" MIN
8"
6"
.

HANDRAIL. SEE 1/AD1.1
(2) #4 CONT.

PEDESTRIAN RAMP.

SEE 1/AD1.0 FOR

REQUIREMENTS

ALIGN TO THE

DEEPEST OF THE
TWO

TOP OF PAVING/PLAN

FINISH GRADE
TRUCK RAMP. SEE

STRUCTURAL FOR

REQUIREMENTS
6" MIN ABOVE

THE HIGHEST

ADJACENT
RAMP
HSS GATE FRAME w/ HEAVY

DUTY HINGES
HSS 1x1 PICKETS @ 6" O.C.

HSS GATE POST W/ ANGLE CLIPS TO

SCREEN WALL (WHERE OCCURS) &
EMBEDDED IN CONCRETE FOOTING.

SEE DETAIL ABOVE

SCREEN WALL WHERE
OCCURS

DIAGONAL BRACE ON BACK SIDE

OF GATE
6" MAX CLEARANCE
3/4" DIA CANE BOLTS IN STEEL SLEEVES.

OMIT IF GATE BEING MOTORIZED AS

PART OF THIS SCOPE
.

GATE NOTES:

1. THE GATES SHALL BE DESIGNED, CONSTRUCTED, AND

INSTALLED TO BE EITHER MOTORIZED AT THE TIME OF
INSTALLATION (CONFIRM w/ OWNER OR BUILDING

DEPARTMENT) OR TO BE CAPABLE OF BEING MOTORIZED AT A
FUTURE DATE. GATES SHALL COMPLY w/ ALL RELEVANT
REQUIREMENTS OF ASTM F2200 (CBC 3110.3). OMIT
PERFORATED STEEL COVERING (NOTE 6 BELOW) IF NOT

REQUIRED BY PLANNING AND IF OPERATORS ARE NOT BEING
INSTALLED AS PART OF THIS SCOPE. IF OPERATORS ARE
BEING INSTALLED THEY MUST COMPLY WITH UL 325

2. GATE ASSEMBLY TO BE FULLY WELDED & PREFINISHED,
COLOR BY ARCHITECT.

3. ENTIRE GATE ASSEMBLY TO BE DESIGN BUILD . MUST BE

DESIGNED TO LOCAL JURISDICTION WIND LOADING
REQUIREMENTS.

4. SLOPE BOTTOM OF GATE AS REQUIRED TO MAINTAIN MAX
CLEARANCE SHOWN.

5. PROVIDE PAINTED 65% OPEN PERFORATED STEEL
COVERING OVER ENTIRE GATE.

6. GATES SHALL BE DESIGNED TO NOT BE MOVEABLE WHEN
DISCONNECTED FROM THE CURRENT OR FUTURE OPERATOR.

7. VEHICULAR GATES IF MOTORIZED SHALL HAVE A MINIMUM
OF TWO (2) EASILY VISIBLE WARNING SIGNS INSTALLED ON
EACH SIDE OF THE GATE MEETING WITH ANSI Z535. LAYOUT
TO COMPLY WITH UL 325 (CBC 3110.4)

8. GATES SHALL BE DESIGNED, CONSTRUCTED, AND

INSTALLED SUCH THAT THEIR MOVEMENT SHALL NOT BE

INITIATED BY GRAVITY WHEN DISCONNECTED FROM AN

AUTOMATIC OPERATOR & SHALL NOT FALL OVER MORE THAN
45 DEGREES FROM THE VERTICAL PLANE WHEN DETACHED
FROM SUPPORTING HARDWARE.

9. THE GENERAL CONTRACTOR SHALL COORDINATE THE

REQUIRED FOOTING FOR THE GATE POST WITH ANY
ADJACENT SCREEN WALL OR PILASTER FOOTINGS.

SCREEN WALL WHERE OCCURS
GATE POST. ALIGN FACE w/
F.O. SCREEN WALL AS SHOWN
GATE HINGE. ALIGN w/ F.O.

GATE POST AS SHOWN

SWINGING GATE
?
?

STANDARD & EV

CAPABLE STALLS

EVCS STALLS

FACE OF BUILDING, SITE
1' - 6"
WALL, OR CURB.

EV

CHARGING
ONLY

PAINT THE TEXT SHOWN

BELOW IN THE SAME

COLOR AS THE STALL
STRIPING. ALIGN THE

LOWER EDGE OF THE

BOTTOM LINE OF TEXT

WITH THE END OF THE

STALL STRIPING SO THAT

IT IS VISABLE BENEATH A
PARKED VEHICLE.

PM CONFIRM SINGLE OR

HAIRPIN STRIPING AND

WIDTH OF STRIPES

MATCH STANDARD STALL

DIMENSIONS
MIN LEVEL 2 EV SUPPLY EQUIPMENT
(EVSE). CENTER ON STALL (OR
BETWEEN STALLS WHEN 2 STALLS
ARE SHARING). SEE SITE PLAN AND

ELCTRICAL DRAWINGS

PM CONFIRM
STALL

DIMENSIONS

AND ADD

COMPACT

STALL SIZE IF

APPLICABLE

PM CONFIRM IF YOU HAVE

STALL OVERHANG INTO

PLANTER & IF SO MODIFY
DETAIL

NOTE - ALL STALL

STRIPING AND TEXT TO

RECEIVE TWO COATS
OF PAINT.
12".

CLR.

PROVIDE FOR
FUTURE EVSE @ EV
CAPABLE STALLS.

SEE ELECTRICAL

DRAWINGS

PROVIDE EVCS STALL
SIGNAGE. SEE 6/A0.2.1
TUBULAR STEEL FENCING7 1/4" = 1'-0"
12 ROLLING GATE TRACK SCALE: N.T.S.

EXTERIOR CHAIN LINK FENCING6 1/4" = 1'-0"
15 ROLLING GATE SUPPORT 1/2" = 1'-0"
CHECKED BY:

H-A&D JOB NO:

DRAWING SCALE:

DRAWING INFO

MECHANICAL ENGINEER

PLUMBING ENGINEER

ELECTRICAL ENGINEER

STRUCTURAL ENGINEER

FIRE PROTECTION

PROJECT TEAM

GENERAL CONTRACTOR

PROJECT NAME
CLIENT
3800 EAST COAST HWY, STE. 6
CORONA DEL MAR, CA 92625
TEL. 714.389.2800
PROJECTADMIN@
HERDMAN-AD.COM
ISSUE DATE:

SHEET

AS NOTED

CIVIL ENGINEER
THESE DRAWINGS AND SPECIFICATIONS ARE THE PROPERTY AND COPYRIGHT OF HERDMAN A+D AND SHALL NOT BE USED ON ANY OTHER WORK EXCEPT BY AGREEMENT WITH HERDMAN A+D. WRITTEN DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS AND SHALL BE VERIFIED ON THE JOB SITE. ANY DISCREPANCY SHALL BE BROUGHT TO THE NOTICE OF HERDMAN A+D PRIOR TO THE COMMENCEMENT OF ANY WORK.

DRAWN BY:
10/31/2025 10:02:23 AM
C:\Users\sage\Documents\A22-2164 NPP 10990 Woodside Ave Santee_sageC774U.rvt AD1.1

SITE DETAILS
Checker
A22-2164

SANTEE, CA

PALISADE
SANTEE

COMMERCE
CENTER

COMPANY NAME

COMPANY NAME

COMPANY NAME

COMPANY NAME

COMPANY NAME

COMPANY NAME
6TH PLANNING
SUBMITTAL10.31.25
NORTH

PALISADE

PARTNERS

COMPANY NAME
Approver
13 ROLLING GATE 1/4" = 1'-0" HANDRAIL @ ACCESSIBLE RAMP1 1/2" = 1'-0" CONCRETE MOW STRIP2 3" = 1'-0"
3/4" = 1'-0"

PIPE BOLLARD PROTECTION
POST
3 3/4" = 1'-0"

PRECAST CONCRETE WHEEL
STOP
5 1/2" = 1'-0" ACCESSIBLE RAMP @ ROLLING
GATE RECESS 16
10 TRASH ENCLOSURE GATE 1/2" = 1'-0"
11 GATE HINGE 3" = 1'-0"
SHOWN @ BI-PARTING GATES CONDITION. SIMILAR @ TELESCOPING GATES 1/2" = 1'-0"
PEDESTRIAN GATE @ SCREEN
WALL. SIM @ TUBE STEEL FENCE
8 PEDESTRIAN GATE HINGE9 3" = 1'-0"
1/2" = 1'-0" ACCESSIBLE RAMP @ BLDG
WALL 18 RAMP DETAIL 1" = 1'-0" 17
14 SWINGING GATES 1/4" = 1'-0"

ID DATE DESCRIPTION
1 Date 1 Revision 1
3/16" = 1'-0"

NON ACCESSIBLE PARKING
STALLS
4 NOT FOR CONSTRUCTION

NOT FOR CONSTRUCTION

NOT FOR CONSTRUCTION
T

NOT FOR CONSTRUCTION

DIVERSION MANHOLE DETAIL
27 PLAN VIEW

SECTION VIEW

10 10 10 10 11
6 10 10 10 10 11111111
3 5
2 12 10 10 10 10 11 11 10 10
6 8
6 10 10 10 10 10 10 10 101013
914 11111111 12
3 4
5 2 FC-1.0 SITE PHOTOMETRIC PLAN BUILDING 1 ELECTRICAL SITE PHOTOMETRIC PLAN BUILDING 1 1 N

PROJECT
1ST ENTITLEMENT SUBMITTAL A21-2204SANTEE, CA XX.XX.2022

PALISADE SANTEE COMMERCE CENTER KEY PLAN
A FC1.0 FC2.0 BUILDING 1

WHEATLANDS CT WHEATLANDS AVE
10 12 11 11 10 10
6 8 10 10 10 10 10 101013
914 12
3 4
5 2 12 10 10 10 10 11 11 10 10
6 8
6 10 10 10 10 10 10 10 101013
914 11111111 12
3 4
5 2 FC-2.0 SITE PHOTOMETRIC PLAN BUILDING 2

PROJECT
1ST ENTITLEMENT SUBMITTAL A21-2204SANTEE, CA XX.XX.2022 PALISADE SANTEE COMMERCE CENTER ELECTRICAL SITE PHOTOMETRIC PLAN BUILDING 2 1 N KEY PLAN
A FC1.0 FC2.0 BUILDING 2 WHEATLANDS AVE

N WOODSIDE AVE
ENLARGEMENT 'A', THIS SHEET E A D 5 1 2 1 1 3 5 5 4 6 P.L. P.L. P.L. P.L. 3 A' 'A
B' 'B 8 A SECTION 'B-B', SHEET L-2 SECTION 'A-A', SHEET L-2 F E 2 D D GROUND COVERS SYMBOL NAME WUCOLS ACHILLEA 'MOONSHINE', MOONSHINE YARROW 1 GAL. SIZE @ 24" O.C. L LANTANA CAMARA 'DWARF GOLD', DWARF LANTANA 1 GAL. SIZE @ 30" O.C. L STIPA PULCHRA, PURPLE NEEDGRASS 1 GAL. SIZE @ 24" O.C. M SALVIA CLEVLANDII, CLEVLAND SAGE 5 GAL. SIZE @ 48" O.C. L DIANELLA TASMANICA 'VARIEGATA', WHITE STRIPED TASMAN FLAX LILY 1 GAL. SIZE @ 24" O.C. M MYOPORUM PARVIFOLIUM, CREEPING MYOPORUM 1 GAL. SIZE @ 24" O.C. L CARISSA MACROCARPA 'GREEN CARPET', NATAL PLUM 1 GAL. SIZE @ 30" O.C. M ENCELIA CALIFORNIA, 5 GAL. SIZE @ 36" O.C. L AGAVE 'BLUE FLAME', BLUE FLAME AGAVE 5 GAL. SIZE @ 36" O.C. L LEYMUS C. 'CANYON PRINCE', CANYON PRINCE WILD RYE 1 GAL. SIZE @ 36" O.C. L DIETES BICOLOR, FORTNIGHT LILY1 GAL. SIZE @ 24" O.C. M VERBENA 'DE LA MINA', DE LA MINA VERBENA1 GAL. SIZE @ 24" O.C. L ASCLEPIAS SUBULATA, DESERT MILKWEED1 GAL. SIZE @ 30" O.C. L HESPERALOE PARVIFLORA, RED YUCCA 5 GAL. SIZE @ 30" O.C. L YUCCA ROSTRATA, YUCCA5 GAL. SIZE @ 36" O.C. L TREES SYMBOL TREE NAME QTY. WUCOLS PRUNUS CAROLINIANA 'COMPACTA', CAROLINA LAUREL CHERRY 15 GAL. SIZE 60 L FLOWERING ACCENT TREE AT BLDG AND PROJECT ENTRIES CERCIDIUM FLORIDUM, BLUE PALO VERDE 36" BOX SIZE. MULTI-TRUNK 3 L EVERGREEN PARKING LOT SHADE TREE QUERCUS ILEX, HOLLY OAK 24" BOX SIZE [SEE PLAN FOR LOCATION OF (3) 36" BOX SIZE] 30 - 24" 3 - 36" L EVERGREEN SCREEN TREE SALIX SPP., WILLOW 24" BOX SIZE 40 L CALIFORNIA NATIVE SCREEN TREE QUERCUS AGRIFOLIA, COAST LIVE OAK 24" BOX SIZE [SEE PLAN FOR LOCATION OF (14) 36" BOX SIZE] 7 - 24" 14 - 36" L VERTICAL GROWING TREE ADJACENT TO BUILDING TRISTANIA CONFERTA, BRISBANE BOX 15 GAL. SIZE 8 M VERTICAL GROWING TREE ADJACENT TO BUILDING GEIJERIA PARVIFLORA, AUSTRALIAN WILLOW 15 GAL. SIZE 56 L CALIFORNIA NATIVE TREE PLATANUS RACEMOSA, WESTERN SYCAMORE 15 GAL. SIZE 7 M PLANTING LEGEND SHRUBS - SHRUBS SHALL BE CHOSEN FROM THE FOLLOWING: SYMBOL NAME WUCOLS SAMBUCUS NIGRA, ELDERBERRY 5 GAL. SIZE L SENNA ARTEMISIODES, FEATHERY CASSIA 5 GAL. SIZE L LEUCOPHYLLUM FRUTESCENS, TEXAS RANGER 5 GAL. SIZE L OLEA 'LITTLE OLLIE', DWARF OLIVE 5 GAL. SIZE L LIGUSTRUM TEXANUM, TEXAS PRIVET 5 GAL. SIZE L HETEROMELES ARBUTIFOLIA, TOYON 5 GAL. SIZE L HETEROMELES ARBUTIFOLIA, TOYON 15 GAL. SIZE L NOTE: APPLY A 3" MIN. LAYER OF MULCH TOP DRESSING WITHIN ALL PLANTING AREAS. A SAMPLE IS REQUIRED PRIOR TO APPLICATION. ACCENT SUCCULENTS SYMBOL SHRUB NAME QTY. WUCOLS AGAVE WEBERII, WEBER'S AGAVE 15 GAL. SIZE 2 VL AGAVE 'MEDIOPICTA ALBA', VARIEGATED AGAVE 5 GAL. SIZE @ 30" O.C. 4 VL AGAVE PARRYI VAR. 'TRUNCATA', ARTICHOKE AGAVE 5 GAL. SIZE @ 30" O.C. 4 VL DESIGN KEY NOTES: 1. SCREEN SHRUBS ALONG PROPERTY LINE PER PLANTING LEGEND. 2. SCREEN TREES ALONG PROPERTY LINE PER PLANTING LEGEND. 3. PARKING LOT SHADE TREE WITHIN 30' OF EACH CAR PARKING STALL, PER COUNTY OF SAN DIEGO LANDSCAPE REQUIREMENTS. 4. FLOWERING ACCENT TREES AT FOCAL AREAS PER PLANTING LEGEND. 5. VERTICAL TREE AT BUILDING PER PLANTING LEGEND. 6. RIVER ADJACENT CALIFORNIA NATIVE TREES PER PLANTING LEGEND. 7. SUCCULENT PLANTING AREA IN DECOMPOSED GRANITE AT BUILDING ENTRY. 8. ENHANCED PAVING AT BUIDLING ENTRY. INTEGRAL COLORED CONCRETE WITH MEDIUM ETCH FINISH. REFERENCE NOTES: A. CONCRETE WALKWAY PER CIVIL PLANS. B. GATE PER ARCH. PLANS. C. TRASH ENCLOSURE PER ARCH. PLANS. D. BIKE RACK PER ARCH. PLANS. E. ELEC. TRANSFORMER PER ARCH. PLANS. F. EMPLOYEED BREAK PER ARCH. PLANS. DATE: 11/12/25 PALISADE SANTEE BUSINESS CENTER SANTEE, CA CONCEPTUAL LANDSCAPE PLAN SCALE: 1" = 40'-0" 0 40' 80' 120' NORTH L-1 THIS IS A CONCEPTUAL LANDSCAPE PLAN. IT IS BASED ON PRELIMINARY INFORMATION WHICH IS NOT FULLY VERIFIED AND MAY BE INCOMPLETE. IT IS MEANT AS A COMPARATIVE AID IN EXAMINING ALTERNATE DEVELOPMENT STRATEGIES AND ANY QUANTITIES INDICATED ARE SUBJECT TO REVISION AS MORE RELIABLE INFORMATION BECOMES AVAILABLE. CONCEPTUAL PLAN NOTE: LANDSCAPE CALCULATIONS TOTAL SQ. FOOTAGE OF LANDSCAPE AREAS = 38,761 SQ FT TOTAL PARKING AREA = 45,621 SQ FT TOTAL PARKING AREA LANDSCAPED = 15,879 SQ FT (35% OF TOTAL PARKING AREA) TOTAL TREE COUNT = 217 TREES WUCOLS PLANT FACTOR THIS PROJECT IS LOCATED IN 'WUCOLS' REGION '3-SOUTH COASTAL. H = HIGH WATER NEEDS M = MODERATE WATER NEEDS L = LOW WATER NEEDS VL= VERY LOW WATER NEEDS PROPOSED BUILDING WOODSIDE AVENUE NORTH SAN DIEGO RIVER ENLARGEMENT KEY NOTES: 1. INTEGRAL COLORED CONCRETE WITH MEDIUM ETCH FINISH 2. DECORATIVE ROCK MULCH OR DECOMPOSED GRANITE AT BUILDING ENTRY AREA 3. ACCENT SHRUBS AND SUCCULENTS AT DECORATIVE NON-ORGANIC MULCH AREA 4. BIKE RACK PER ARCH. 5. DROUGHT TOLERANT SHRUBS AND GROUND COVER (REGULAR PLANTING AREAS, GREEN NON DG) 2 ENLARGEMENT 'A' - SOUTH EAST BUILDING ENTRY SCALE: 1"=20' BUILDING (3) 36" BOX SIZE QUERCUS TREES (4) 36" BOX SIZE QUERCUS TREES PRECAST CONCRETE WALL PER ARCH. PLANS FINAL LOCATION OF SCREEN TREES SHALL BE COORDINATED TO AVOID ANY POTENTIAL CONFLICTS WITH WALL FOOTING, TYP. (4) 36" BOX SIZE QUERCUS TREES (6) 36" BOX SIZE QUERCUS TREES (2) 36" BOX SIZE QUERCUS TREES PROPOSED BUILDING 143 5 A'
'A
B' 'B BUILDING PROP. CURB PROP. CURB & GUTTER PROP. FENCEPROPERTY LINE 4' DEEPENED FOOTING TRANSITION PROP. AC PAVEMENT EXIST. WATER-WAY EXIST. WATER-WAY EXIST. FENCE 594'-0" 68'-0" 8'-0" 640'-5" EXIST. FENCE EXIST. WATER-WAY EXIST. WATER-WAY BUILDING PROPERTY LINE 24'-0" 61'-0" 27'-0" PROP GB PROP. CURB & GUTTER PROP. FENCE PROP. AC PAVEMENT PROP. CURB 1.88' DEEP PROP. FOOTING T WALK PALISADE SANTEE BUSINESS CENTER SANTEE, CA LANDSCAPE SECTIONS SCALE: 1" = 90'-0" 0 90' 180' 270' NORTH L-2 PROPOSED BUILDING WOODSIDE AVENUE NORTH SAN DIEGO RIVER SECTION 'A-A' SCALE: 1" = 20'-0" SECTION 'B-B' SCALE: 1" = 20'-0" DATE: 10/31/25 NORTH

PROJECT
10/31/2025 10:02:23 AM
A22-2164

SANTEE, CA
6TH PLANNING
SUBMITTAL10.31.25
R-1

RENDERING

PALISADE SANTEE COMMERCE CENTER
NORTH

PROJECT
10/31/2025 10:02:24 AM
A22-2164

SANTEE, CA
6TH PLANNING
SUBMITTAL10.31.25
R-2

RENDERING

PALISADE SANTEE COMMERCE CENTER
NORTH

PROJECT
10/31/2025 10:02:24 AM
A22-2164

SANTEE, CA
6TH PLANNING
SUBMITTAL10.31.25
R-3

RENDERING

PALISADE SANTEE COMMERCE CENTER
NORTH

PROJECT
10/31/2025 10:02:24 AM
A22-2164

SANTEE, CA
6TH PLANNING
SUBMITTAL10.31.25
R-4

RENDERING

PALISADE SANTEE COMMERCE CENTER
NORTH

PROJECT
10/31/2025 10:02:24 AM
A22-2164

SANTEE, CA
6TH PLANNING
SUBMITTAL10.31.25
R-5

RENDERING

PALISADE SANTEE COMMERCE CENTER