PART 3 - 207
SPECIFICATIONS
e. D140/140M 2016 Standard Practice for Sampling Asphalt Materials f. D217 2017 Standard Test Methods for Cone Penetration of Lubricating Grease
g. D244 2009 Standard Test Methods and Practices for Emulsified Asphalts
h. D297 2015 Standard Test Methods for Rubber Products—Chemical Analysis
i. D445 2017 Standard Test Method for Kinematic Viscosity of Transparent and Opaque Liquids (and Calculation of Dynamic Viscosity) j. D562 2010 Standard Test Method for Consistency of Paints Measuring Krebs Unit (KU) Viscosity Using a Stormer-Type Viscometer k. D2007 2011 Standard Test Method for Characteristic Groups in Rubber Extender and Processing Oils and Other Petroleum-Derived Oils by the Clay-Gel Absorption Chromatographic Method
l. D2042 2015 Standard Test Method for Solubility of Asphalt Materials in Trichloroethylene or Toluene
m. D3111 2010 Standard Practice for Flexibility Determination of Hot-Melt Adhesives by Mandrel Bend Test
n. D3723 2005 Standard Test Method for Pigment Content of WaterEmulsion Paints by Low-Temperature Ashing o. D3910 2015 Standard Practices for Design, Testing, and Construction of Slurry Seal
p. D5329 2016 Standard Test Methods for Sealants and Fillers, HotApplied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements
q. D4791 2010 Standard Test Method for Flat Particles, Elongated Particles, or Flat and Elongated Particles in Coarse Aggregate r. D6943 2015 Standard Practice for Immersion Testing of Industrial Protective Coatings and Linings
s. D7428 2015 Standard Test Method for Resistance of Fine Aggregate to Degradation by Abrasion in the Micro-Deval Apparatus
t. D7741 2011 Standard Test Method for Measurement of Apparent Viscosity of Asphalt-Rubber or Other Asphalt Binders by Using a Rotational Hand Held Viscometer
u. E70 2007 Standard Test Method for pH of Aqueous Solutions With the Glass Electrode
3. CALIFORNIA TEST METHODS (CT)
a. CT 125 1998 Sampling Highway Materials and Products Used in the Roadway Structural Sections
b. CT 202 2002 Method for Test for Sieve Analysis of Fine and Coarse Aggregates c. CT 205 2010 Method of Test for Percentage of Crushed Particles d. CT 208 2011 Method of Test for Apparent Specific Gravity of Fine Aggregates e. CT 211 2010 Method of Test for Abrasion of Coarse Aggregate by Use of the Los Angeles Abrasion Testing Machine
f. CT 217 2011 Method of Test for Sand Equivalent
g. CT 227 2012 Method of Test for Evaluating Cleanness of Coarse Aggregate h. CT 229 2011 Method of Test for Durability Index
i. CT 302 2014 Method of Test for Film Stripping
j. CT 331 2017 Method of Test for Residue by Evaporation of Latex Modified Asphaltic Emulsion
k. CT 332 2017 Method of Test for Torsional Recovery of Polymer Modified Asphalt Emulsion Residue
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 208
SPECIFICATIONS
l. CT 339 2000 Method of Field Test for the Determination of Distributor Spread Rate
m. CT 385 2007 Method of Test for Crumb Rubber Modifier n. CT 388 2014 Method of Test for Sampling and Reheating Asphalt Rubber Binder Field Samples Prior to Viscosity Testing in Accordance to ASTM D 7741 o. CT 401 2012 Method of Test for Latex Concentration in Asphalt Emulsions p. CT 413 2012 Determination of Chloride Content in Organic Additives for Portland Cement Concrete
q.
4. State of California, Business and Transportation Agency, Department of Transportation (Caltrans), Standard Specifications, 2018 edition excluding measurement and payment items.
1.2 SUBMITTALS
A. At least 15 days before starting placement of a slurry seal or micro-surfacing, submit:
1. Asphaltic emulsion, polymer modified asphaltic emulsion, or micro-surfacing emulsion data as follows:
a. Supplier and Type/Grade of asphaltic emulsion;
b. Type of modifier polymer for polymer modified asphaltic emulsion or microsurfacing emulsion; and c. Copy of the specified test results for asphaltic emulsion, polymer modified asphaltic emulsion, or micro-surfacing emulsion.
2. Aggregate test results for the followings:
a. Gradation;
b. Los Angeles Rattler;
c. Percent of crushed particles;
d. Sand equivalent; and
e. Durability.
B. Submit a laboratory report of test results and the proposed mix design from an authorized laboratory. The authorized laboratory must sign the laboratory report and mix design. The report must include:
1. Test results used in the mix design compared with specification requirements
2. Proportions based on the dry weight of aggregate, including ranges, for:
a. Aggregate;
b. Water;
c. Additives;
d. Mineral filler; and
e. Slurry seal emulsion or micro-surfacing emulsion residual asphalt content.
3. Recommended changes to the proportions based on heating the mixture to 100 degrees F and mixing for 60 seconds, if atmospheric temperatures during application will be 90 degrees F or above, for:
a. Water;
b. Additives; and
c. Mineral filler.
4. Quantitative moisture effects on the aggregate's unit weight determined under ASTM C29M
C. If the mix design consists of the same materials covered by a previous laboratory report, you may submit the previous laboratory report that must include material testing data performed within the previous 12 months for authorization.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 209
SPECIFICATIONS
D. If you change any of the materials in the mix design, submit a new mix design and laboratory report at least 10 days before starting slurry seal or micro-surfacing work.
E. Submit a certificate of compliance as specified for asphaltic emulsion in section 94-1.01C of the Standard Specifications with each shipment of asphaltic emulsion, polymer modified asphaltic emulsion or micro-surfacing emulsion.
F. The Contractor shall furnish to the Engineer weight or load slips verifying the quantities of aggregate and asphaltic emulsion. Slips shall be provided to the Engineer on the day of the delivery.
1.3 ENGINEER’S ACCEPTANCE
A. Slurry seal acceptance is based on:
1. Visual inspection for the following:
a. Uniform surface texture throughout work limits.
b. Marks in the surface:
1) Up to 4 marks in the completed slurry seal that are up to 1 inch wide and up to 6 inches long per 1,000 square feet of slurry seal placed, at discretion of the Engineer.
2) No marks in the completed slurry seal that are over 1 inch wide or 6-inches long.
c. Excessive raveling consisting of the separation of the aggregate from the polymer modified asphaltic emulsion.
d. Bleeding consists of the occurrence of a film of asphalt material on the surface of the slurry seal or micro-surfacing.
e. Delaminating of slurry seal from the existing pavement f. Rutting or wash-boarding.
g. Any other visible defect in the quality of the work.
PART 49 PRODUCTS
1.1 AGGREGATE
A. Aggregate for slurry seal must comply with the gradations shown for Type II. Aggregate for slurry seal shall be black in color.
1.2 SLURRY SEAL
A. POLYMER MODIFIED ASPHALTIC EMULSIONS
1. Asphalt emulsion shall be polymer modified asphalt emulsion, grade PMCQS1h cationic conforming with the requirements of Section 2.2(A) “Polymer Modified Asphaltic Emulsions” and conform to the requirements in the Standard Specifications.
PART 50 EXECUTION
1.1 GENERAL
A. Prior to applying the slurry seal, loose materials, oil spots, dirt, pavement striping and markers, vegetation and other objectionable material that may compromise the slurry seal to be placed shall be removed from the existing surface and the pavement structural integrity shall be restored. The pavement surface shall be cleaned by sweeping, flushing or other means necessary to remove all extraneous material. The Engineer shall approve all surface preparation prior to the application of slurry seal.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 210
SPECIFICATIONS
B. Use grinding or other approved methods for striping, pavement marking or pavement marker removal, including removal of existing double-sided yield to pedestrian object marker.
C. Use grinding or other approved methods for striping, pavement marking or pavement marker removal, including removal of existing double-sided yield to pedestrian object marker.
D. All crack sealing work shall be completed prior to application of slurry seal.
E. Prior to commencing the slurry seal operation, all surface utility covers including but not limited to survey monuments, manholes, water valves, etc. shall be protected by thoroughly covering the surface with an appropriate adhesive and oiled or plastic paper. No adhesive material shall be permitted to cover, seal or fill the joint between the frame and cover of the structure.
Covers are to be uncovered and cleaned of slurry material by the end of the same work day.
The Contractor shall take precautions to remove any slurry that may cover these appurtenances.
F. Protection and maintenance of the street surface to the condition required for proper slurry application shall be the sole responsibility of the Contractor and no additional expense will be allowed. The Contractor shall, at the direction of the City, repair and reseal all areas of the street which have not been sealed properly and completely or have been damaged by traffic.
1.2 PROPORTIONING
A. Protection and maintenance of the street surface to the condition required for proper slurry application shall be the sole responsibility of the Contractor and no additional expense will be allowed. The Contractor shall, at the direction of the City, repair and reseal all areas of the street which have not been sealed properly and completely or have been damaged by traffic.
B. The delivery rate of aggregate and emulsion per revolution of the aggregate feeder shall be calibrated at the appropriate gate settings for each mixer-spreader truck used on the project.
The calibration shall demonstrate that delivery rates of dry aggregate and emulsion residue are within the recommended percentages stated in the laboratory mix design. The Contractor shall provide written calibration documentation for each application truck which has been performed within the last calendar year. The Contractor shall further provide a short calibration demonstrating gate settings and liquids are delivering job materials within the mix design recommended ranges.
1.3 MIXING AND SPREADING EQUIPMENT
A. All equipment, tools, and machines used in the application of slurry seal shall be maintained in satisfactory working condition at all times. A minimum of two (2) slurry seal machines shall be on the job and in good operating condition at all times.
B. The slurry seal shall be mixed in a self-propelled mixing machine equipped with a continuous flow pug mill, capable of accurately delivering and automatically proportioning the aggregate, emulsified asphalt, mineral filler, water and admixtures to a double shafted, multi-blade pug mill mixer capable of minimum speeds of 200 revolutions per minute. Mix retention time in the pug mill shall be less than three (3) seconds. The mixing machine shall have sufficient storage capacity of aggregate, emulsified asphalt, mineral filler and water to maintain an adequate supply to the proportioning controls and make fifteen (15) tons of emulsion mix.
C. The mixing machine shall be equipped with hydraulic controls for proportioning the material by volume to the mix. Each material control device shall be calibrated, properly marked, pre-set and lockable.
D. The mixing machine shall be equipped with a water pressure and nozzle type spray bars to provide a water spray immediately ahead of the spreader box. The mixing machine shall be equipped with an approved fines feeder that provides a uniform, positive, accurately metered, Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 211
SPECIFICATIONS
pre-determined amount of the mineral filler at the same time and location that the aggregate is fed.
E. A burlap drag or other approved flexible drag or screed shall be attached to the rear of the spreader box. A drag stiffened by hardened slurry is ineffective and is to be replaced immediately.
F. The slurry seal retention time in the pug mill shall be less than three seconds. No retention of mixed slurry seal shall be allowed within the pug mill by gate shut-off or other mechanical means. Transit mix trucks shall not be used.
1.4 PLACEMENT
A. The slurry seal (mixture) shall be spread per the application range requirements of Type II slurry seal per Section 3.4 “Placement,” of the Standard Specifications.
B. The slurry seal shall not be placed if either the temperature or the air temperature is below 55 degrees F and falling, but may be applied when both the air and pavement temperature is 45 degrees F or above and rising. The mixture shall not be applied if high relative humidity prolongs the curing beyond a reasonable time.
C. Longitudinal joints shall be butt jointed and should be located outside of the typical wheel paths, where possible.
D. Handwork shall be kept to a minimum. Areas which cannot be accessed by the mixing machine shall be surfaced using hand squeegees to provide complete and uniform coverage.
Handwork shall exhibit the same finish as that applied by the spreader box and shall be completed prior to final surfacing. Hand tools shall be available to remove spillage. Ridges or bumps in the finished surface will not be permitted. The mixture shall be uniform and homogeneous after spreading on the existing surface and shall not show separation of the emulsion and aggregate after setting.
E. The Contractor shall exercise care to prevent slurry from being deposited on concrete surfaces. The Contractor shall remove slurry from surfaces not designated to be sealed each day. No additional streets shall be slurry sealed until this clean-up has been performed. The method of slurry removal shall be approved by the City. All streets to be slurry sealed shall be sealed from edge of pavement to edge of pavement. The slurry shall fully extend up to the lip of gutter but shall not overlap the gutter by more than 1 inch. Excess overlay shall be removed by methods that shall not damage the remaining slurry seal. Spreaders to be used for this operation shall meet the approval of the City.
F. The sites for stockpiling and batching materials shall be clean and free from objectionable materials and shall be located outside the road right-of-way. Arrangements for these sites shall be the responsibility of the Contractor. The Contractor shall provide to the City an executed written agreement with the property owner prior to commencing operations.
G. Any areas of chatter (wash boarding), poor coating, delaminating, segregation, uneven surfaces or poor joints shall be corrected. If any of these conditions are observed, the placement of slurry seal shall be stopped until corrections are made to the equipment to prevent such defects. At the Contractor’s expense, the Contractor shall be responsible for correcting any slurry placement that exhibits poor quality or workmanship, whether these conditions were observed during placement or after the slurry seal mix has cured.
H. No loads may begin to be applied after 2:00 PM.
I. The Contractor will only be permitted to continue with production if the following conditions are met:
1. The pavement has been properly cleaned initially and thereafter as necessary; Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 212
SPECIFICATIONS
2. Delivery tickets, samples and certificates of compliance are delivered to the Engineer by the end of the day (5:00 PM latest);
3. Complete daily production records are delivered to the Engineer by the end of the day (5:00 PM latest); and
4. Workmanship is acceptable including cleaning up of edges.
J. After completing slurry seal application, the Contractor shall perform complete sweepings of the project and adjacent streets where any materials have been tracked.
K. Within 4 hours after placement, slurry seals must be set enough to allow traffic without pilot cars. Protect slurry seals from damage until it has set and will not adhere or be picked up by vehicle tires. Slurry seals must not exhibit distress from traffic such as bleeding, raveling, separation or other distresses.
END OF SECTION
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 213
SPECIFICATIONS
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 214
SPECIFICATIONS
SECTION 33 05 13
MANHOLES
PART 1 GENERAL
1.01. SUMMARY
A. Section Includes:
1. Monolithic concrete manholes and structures, including catch basin, and channel drains, with transition to cover frame, covers, anchorage, and accessories.
2. Modular precast concrete manhole and structures with tongue-and-groove joints, covers, anchorage, and accessories.
3. Bedding and cover materials.
B. Related Sections:
1. Section 03 30 00 - Cast-in-Place Concrete
2. Section 31 00 00 - Earthwork.
3. Section 31 23 00 – Trench Excavation Backfill
1.02. REFERENCES
A. American Concrete Institute:
1. ACI 318 - Building Code Requirements for Structural Concrete.
B. ASTM International:
1. ASTM A48/A48M - Standard Specification for Gray Iron Castings.
2. ASTM C1244-20 - Standard Test Method for Concrete Sewer Manholes by the Negative Air Pressure (Vacuum) Test Prior to Backfill
3. ASTM C478 - Standard Specification for Precast Reinforced Concrete Manhole Sections.
4. ASTM C497 - Standard Test Methods for Concrete Pipe, Manhole Sections, or Tile.
5. ASTM C913 - Standard Specification for Precast Concrete Water and Wastewater Structures.
6. ASTM C923 - Standard Specification for Resilient Connectors between Reinforced Concrete Manhole Structures, Pipes and Laterals.
1.03. DESIGN REQUIREMENTS
A. Equivalent strength: Based on structural design of reinforced concrete as outlined in ACI 318.
B. Design of Lifting Devices for Precast Components: In accordance with ASTM C913.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 215
SPECIFICATIONS
C. Design of Joints for Precast Components: In accordance with ASTM C913; maximum leakage of 0.025 gallons per hour per foot of joint at 3 feet of head.
1.04. SUBMITTALS
A. Section 01 33 00 - Submittals: Requirements for submittals.
B. Product Data: Submit cover and frame construction, features, configuration, and dimensions.
1.05. QUALITY ASSURANCE
A. Perform Work in accordance with City of Santa Rosa Sanitary Sewer Standard Specifications (Section 130).
1.06. QUALIFICATIONS
A. Manufacturer: Company specializing in manufacturing products specified in this Section with minimum three years documented experience.
1.07. DELIVERY, STORAGE AND HANDLING
A. Section 01 60 00 - Product Requirements: Product storage and handling requirements.
B. Comply with precast concrete manufacturer’s instructions for unloading, storing and moving precast manholes and structures.
C. Store precast concrete manholes and structures to prevent damage to Owner’s property or other public or private property. Repair property damaged from materials storage.
D. Mark each precast structure by indentation or waterproof paint showing date of manufacture, manufacturer, and identifying symbols and numbers shown on Drawings to indicate its intended use.
PART 2 PRODUCTS
2.01. MANHOLES
A. Manholes: Reinforced precast concrete in accordance with ASTM C478 with gaskets in accordance with ASTM C923.
B. Joint Seal:
1. RAM-NEK or approved equal will be allowed for jointing.
C. Pipe to Manhole Connectors:
1. Flexible couplings shall be as manufactured by Mission Rubber Company or equal.
2.02. FRAMES AND COVERS
A. Manufacturers:
1. D&L Supply A-1024
2. South Bay Foundry SBF 1900 CPH
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 216
SPECIFICATIONS
3. Substitutions: Section 01 60 00 - Product Requirements.
B. Product Description:
1. Casting shall be first-class grey iron, tough, and of even grain, and shall be dipped after they have been thoroughly cleaned in asphalt that has been heated to not less than 200 degrees F.
2. Ring and cover shall be Phoenix Iron Works P-1090 or approved equal with closed pick hole.
a. All material used in manufacturing shall conform to A.S.T.M A-48 Class 35 B or of United States Government Specifications QQ1-652b.
2.03. CONFIGURATION
A. Shaft Construction: Concentric with eccentric cone top section; lipped male/female joints; sleeved to receive pipe sections.
B. Shape: Cylindrical.
C. Clear Inside Dimensions: 48 inch diameter.
D. Design Depth: As indicated on Drawings.
E. Clear Cover Opening: As indicated on Drawings.
F. Pipe Entry: Furnish openings as indicated on Drawings.
2.04. BEDDING AND COVER MATERIALS
A. Bedding: Coarse Aggregate Subbase Fill as specified in Section 31 00 00.
B. Soil Backfill from Above Pipe to Finish Grade: Engineered Fill, as specified in Section 31 00
00. 2.05. INFLOW PROTECTION
A. Inflow Protector Insert: HDPE Syneco Systems PEACEMAKER Inflow Inserts, or approved equal. Size to match.
PART 3 EXECUTION
3.01. EXAMINATION
A. Section 01 30 00 - Administrative Requirements: Verification of existing conditions before starting work.
B. Verify items provided by other sections of Work are properly sized and located.
C. Verify built-in items are in proper location, and ready for roughing into Work.
D. Verify correct size of manhole and structure excavation.
3.02. PREPARATION
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 217
SPECIFICATIONS
A. Coordinate placement of inlet and outlet pipe or duct sleeves required by other sections.
B. Do not install structures where site conditions induce loads exceeding structural capacity of structures.
C. Inspect precast concrete structures immediately prior to placement in excavation to verify structures are internally clean and free from damage. Remove and replace damaged units.
3.03. INSTALLATION
A. Excavation and Backfill:
1. Excavate for manholes and structures in accordance with Section 31 23 00 in location and to depth shown. Provide clearance around sidewalls of structure for construction operations.
2. When groundwater is encountered, prevent accumulation of water in excavations.
Place manholes and structures in dry trench.
3. Where possibility exists of watertight structure becoming buoyant in flooded excavation, anchor structure to avoid flotation.
B. Place manhole base.
C. Place manhole and structure sections plumb and level, trim to correct elevations, anchor to base.
D. Backfill excavations for manholes and structures in accordance with Section 31 23 00.
E. Form and place manhole and structures cylinder plumb and level, to correct dimensions and elevations.
F. Cut and fit for pipe.
G. Grout base of shaft sections to achieve slope to exit piping. Trowel smooth. Contour to form continuous drainage channel.
1. The invert shall be shaped to provide an adequate channel between the inlet and outlet pipes. The channel and shelf shall be steel troweled to a smooth dense surface. Adequate care must be taken to prevent displacement of the sewer pipe from line or grade during construction of the base.
2. The Contractor shall have the option of laying pipe through the manhole, shaping the upper half of the channel and the shelf, and later breaking out the pipe above the spring line, in which case they will be required to patch and smooth up with mortar the broken edges of pipe, or they may stop the pipe at the inside face of the manhole and construct the channel to the shape and size of the pipe. The invert shall follow a straight line between the inlet and outlet pipe, or a smooth curve on an even grade, if changing direction.
H. Set cover frames and covers level without tipping, to correct elevations.
3.04. PRECAST CONCRETE MANHOLE INSTALLATION
A. Lift precast components at lifting points designated by manufacturer.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 218
SPECIFICATIONS
B. When lowering manholes and structures into excavations and joining pipe to units, take precautions to ensure interior of pipeline and structure remains clean.
C. Set precast structures bearing firmly and fully on crushed stone bedding, compacted in accordance with provisions of Section 31 23 00 or on other support system shown on Drawings.
D. Assemble multi-section structures by lowering each section into excavation. Lower, set level, and firmly position base section before placing additional sections.
E. Remove foreign materials from joint surfaces and verify sealing materials are placed properly.
Maintain alignment between sections by using guide devices affixed to lower section.
F. Joint sealing materials may be installed on site or at manufacturer’s plant. Joints shall be filled with mortar consisting of one (1) part cement to three (3) parts sand by volume before placing each section, and after the shaft is in place the joints inside and outside shall be neatly stuck and outside joints shall be banded to insure waterproofing the completed structure.
G. Verify manholes and structures installed satisfy required alignment and grade.
H. Remove knockouts or cut structure to receive piping without creating openings larger than required to receive pipe. Fill annular space with mortar.
I. Cut pipe to finish flush with interior of structure.
J. Shape inverts through manhole and structures as shown on Drawings.
3.05. FRAME AND COVER INSTALLATION
A. Set frames using mortar and masonry.
B. Set frame and cover 2 inches above finished grade for manholes with covers located within unpaved areas to allow area to be graded away from cover beginning 1 inch below top surface of frame.
C. Casting shall be first-class grey iron, tough, and of even grain, and shall be dipped after they have been thoroughly cleaned in asphalt that has been heated to not less than 200 degrees F. After castings have seasoned sufficiently so that there will be no further distortion due to temperature changes, the cover and ring seat shall be machined so that the tops are flush and the entire area of the seat is in contact with the cover in any position of the cover on the seat.
3.06. FIELD QUALITY CONTROL
A. Section 01 40 00 – Quality Control: Field inspecting, testing, adjusting, and balancing.
B. Test concrete manhole and structure sections in accordance with ASTM C-1244-20.
C. Each manhole shall be tested for leakage by plugging the sewer line between the manhole and the first joint. The manhole shall be filled with water to the rim of the frame casting and shall lose no more than 2 inches over a period of 30 minutes. In lieu of water testing, testing of sewer manholes may be done by vacuum testing per the City of Santa Rosa Sanitary Sewer Standard Specifications (Section 130) and ASTM C 1244-20.
END OF SECTION
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 219
SPECIFICATIONS
THIS PAGE LEFT BLANK INTENTIONALLY.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 220
SPECIFICATIONS
SECTION 33 11 00
WATER UTILITIES
13 GENERAL
1 DESCRIPTION
a Section includes: The Contractor shall provide all materials, equipment, and labor necessary to furnish and install all water pipe with all necessary fittings and coupling systems and all appurtenant work, complete and operable, including all connections as shown on the Drawings and as specified herein.
b All water piping materials, equipment and installation shall be in accordance with the AWWA Standards and be NSF-61 certified.
c Section includes:
i Water Main Piping.
ii Gate Valves.
iii Couplings.
iv Bolts and Nuts for Underground Piping and Valves.
v Restrained Joints.
vi Service Saddles.
vii Tapping Sleeves.
viii Corporation Stops.
ix Angle Meter Ball Valves/Curb Stops.
x Service Piping and Fittings.
xi Service Elbows.
xii Valve boxes.
xiii Tracer Wire.
2 RELATED WORK SPECIFIED ELSEWHERE
a Division 1 - General Requirements.
b Section 03 30 00 – Cast-In-Place Concrete.
c Section 31 01 40 - Shoring and Trench Safety.
d Section 31 23 00 - Trench Excavation and Backfill.
e Section 31 23 19 - Dewatering.
f Section 33 13 00 – Disinfecting of Water Utilities
3 REFERENCE SPECIFICATIONS, CODES, AND STANDARDS
a American Public Works Association (APWA)
i Uniform Color Code for Marking of Underground Utility Locations. b American Society of Testing and Materials (ASTM)
i ASTM A193 – Standard Specification for Alloy-Steel and Stainless Steel Bolting Materials for High Temperature or High Pressure Service and Other Special Purpose Applications
ii ASTM A194 – Standard Specification for Carbon and Alloy Steel Nuts for Bolts for High Pressure or High Temperature Service, or Both
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 221
SPECIFICATIONS
iii ASTM A536 – Standard Specification for Ductile Iron Castings iv ASTM D2737 – Standard Specification for Polyethylene (PE) Plastic Tubing v ASTM F477 – Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe
c American Water Works Association (AWWA)
i AWWA C104 – Standard for Cement–Mortar Lining for Ductile-Iron Pipe and Fittings
ii AWWA C105 – Polyethylene Encasement for Ductile-Iron Pipe Systems iii AWWA C110 – Standard for Ductile-Iron and Gray-Iron Fittings iv AWWA C111 – Rubber-Gasket Joints for Ductile-Iron Pressure Pipe and Fittings v AWWA C153 – Standard for Ductile-Iron Compact Fittings for Water Service vi AWWA C504 – Standard for Rubber-Seated Butterfly Valves. vii AWWA C509 – Resilient-Seated Gate Valves for Water Supply Service viii AWWA C550 – Protective Interior Coatings for Valves and Hydrants ix AWWA C600 – Installation of Ductile Iron Water Mains and their Appurtenances. x AWWA C901 – Standard for Polyethylene (PE) Pressure Pipe and Tubing, ½ In. (13 mm) through 3 In. (76 mm), for Water Service – PE material designations PE 2708, PE 3608, and PE 4710.
d National Fire Protection Association (NFPA):
i 24 95 Installation of Private Fire Service Mains and Their Appurtenances ii 291-01 Fire Flow Testing and Marking of Hydrants
e NSF International:
i 61-2022 Drinking Water System Components-Health Effects (Sections 1-9) f American Welding Society (AWS):
i A5.8 04Brazing Filler Metal
g Foundation for Cross-Connection Control and Hydraulic Research-2022 h Copper Development Association Copper Tube Handbook-2010 i City of Santa Rosa Water Standard Specifications (Section 132) 4 QUALITY ASSURANCE
a Standards: The materials and work performed in this Section shall conform to the applicable standards of:
i The American National Standards Institute (ANSI).
ii The American Society for Testing and Materials (ASTM). iii American Water Works Association Inc. (AWWA).
iv The National Sanitation Foundation (NSF).
v The American Society of Mechanical Engineers, Boiler and Pressure Vessel Code (ASME).
vi Plumbing and Drainage Institute (PDI).
vii Underwriters Laboratories Inc. (UL).
viii Uniform Plumbing Code (UPC).
ix National Fire Protection Association (NFPA).
x Factory Mutual Research Corporation (FMRC).
xi City of Santa Rosa Water Standard Specifications (Section 132). b Tests: All materials used in the manufacture of the pipe shall be tested in accordance with the requirements of AWWA and NSF-61, and the referenced standards, as applicable, in addition to national, local, and state codes.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 222
SPECIFICATIONS
c Contractor shall coordinate with and provide a minimum 48 hour notice to the City for all inspections.
d All costs of inspection and tests shall be borne by the Contractor. e The pipe shall be subjected to the specified hydrostatic strength tests, flexure tests, and crushing tests. Hydrostatic testing procedures shall be per City of Santa Rosa Water Distribution System Construction Standard Specifications - Section 132-1.18. The crushing tests shall be made on samples taken from the center of full-length sections of pipe. f The Contractor shall verify with the pipe manufacturer all connection details. g Qualification of manufacturers:
i The material shall be the product of a supplier regularly engaged in the manufacturing of pipe and plumbing products.
ii All materials shall be new and of current manufacture and shall be guaranteed against defects or workmanship in accordance with the General Conditions. h Qualification of installers:
i For the actual assembly, installation, and testing of the work in this Section, use only thoroughly trained and experienced personnel who are completely familiar with the requirements for this work and with the installation recommendations of the manufacturers of the specified items.
ii In acceptance or rejection of installed materials, no allowance will be made for lack of skill on the part of installers.
5 CONTRACTOR SUBMITTALS
a Submittals shall be in accordance with Section 01 33 00, “Submittal Procedures”. Submit complete shop drawings including layouts, elevations, and details to the Engineer. b Submit all product data, shop drawings, laboratory test results, hydrostatic testing procedures, material source information, and certificates of compliance listed in this Section under a single submittal cover for review. Incomplete submittals will not be reviewed. c Material List:
i In accordance with the provisions of Section 01 33 0 “Submittal Procedures” of the Specifications, submit with the shop drawings a complete list of all materials and equipment proposed to be furnished and installed under this portion of the work, giving manufacturer's name, catalog number, and catalog cuts for each item where applicable.
d Manufacturers' Literature and Data (Submit all items as one submittal package for review):
i Piping.
ii Gaskets.
iii Valves.
iv Service line products.
v Valve boxes.
vi Joint restraint.
vii Tapping sleeves.
viii Couplings.
ix Disinfection products.
x Tracing Wire.
e Testing Certifications:
i Hydrostatic Testing
ii Certification of Disinfection, including free chlorine residuals, and bacteriological examinations.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 223
SPECIFICATIONS
f Manufacturer's recommendations:
i Accompanying the materials list and shop drawings, submit four copies of the manufacturer's current recommended method of installation. g Certificates of Compliance: Certificates of Compliance shall be provided for all products and materials proposed to be used under this Section.
6 COORDINATION
a Section 01 30 00 - Administrative Requirements: Coordination and project conditions. 7 DELIVERY, STORAGE, AND HANDLING:
a Coated pipe shall be shipped on bunks, and secured with nylon belt tied down straps or padded banding located approximately over braces. Coated pipe shall be stored on padded skids, sand or dirt berms, sand bags, old tires or other suitable means so that coating will not be damaged. Coated pipe shall be handled with the wide belt slings, padded forks, or other means that will not damage the pipe or coating. Chains, cables or other equipment likely to cause damage to the pipe or coating shall not be used. Prior to shipment, the pipe shall be visually inspected for damage to the coating. Any damaged areas shall be repaired at the Contractor’s expense in accordance with the standard to which the coating was applied. b Deliver and store valves and other materials and appurtenances in shipping containers with labeling in place.
14 PRODUCTS
1 GENERAL
a These Specifications are intended to be standard specifications and they may therefore contain specifications for materials not required for this project or allowed on any or various parts of it. Certain materials, which are applicable for only one portion or a small portion, may be shown on the plans and not particularly specified herein.
b All materials shall conform to sizes, capacity, quality and quantities as shown on the drawings or described in these Specifications. Materials shall be from new stock, delivered in good condition. No damage to stock shall be used.
c Where no method of tests for materials is specified, the latest applicable test specified by ASTM or AWWA shall be followed.
d After delivery to the site, all materials shall be carefully unloaded, protected against breakage, rusting, accumulation of foreign matter, disintegration, and injury. The Contractor shall be responsible for all lost or damaged material supplied and work done under this contract. 2 WATER MAIN PIPING
a PVC Pipe
i Application: Below Grade Pipe Only.
ii The pipe shall be manufactured in strict compliance to AWWA Standard C900, consistently meeting and/or exceeding the Quality Assurance test requirements of this standard with regard to pressure rating, material, workmanship, burst pressure, flattening, impact resistance, and extrusion quality.
iii Pipe: C900 PVC (DR 18) ASTM D1784, Cell Classification of 12454 b Class: DR14 for all water main piping. Ductile Iron Fittings (below grade):
1 Ductile iron: ANSI/AWWA C110/A21.10.
2 Compact fittings ANSI/AWWA C153/A21.53.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 224
SPECIFICATIONS
3 Coating and Lining:
a Bituminous Coating: ANSI/AWWA C110/A21.10.
b Cement Mortar Lining: ANSI/AWWA C104/A21.4, double thickness. c Jackets: ANSI/AWWA C105/A21.5 polyethylene jacket.
3 GATE VALVES
a Size: 2-inch to 12-inch.
b City of Sebastopol Standard 877.
c Resilient Wedge Gate Valves: AWWA C509 and/or C515 of the latest versions. i Body Material: ductile iron.
ii Working Pressure: 250psig.
iii Seat: Resilient.
iv Stem: Non-rising bronze stem with O-ring stem seals. v Operating Nut: 2-inch square; open counterclockwise unless otherwise indicated. vi Ends: Flanged or mechanical joint end connections.
vii Coating: 12-mil holiday-free epoxy AWWA C550; interior/exterior. viii Bolting: Paragraph 2.5.
d Manufacturers:
i Mueller Company
ii Clow Eddy – Iowa
iii US Pipe
iv American Flow Control
v Substitutions: Section 01 60 00 - Product Requirements. 4 COUPLINGS
a Restrained Coupling
i Type: AWWA C219, NSF 61 listed.
ii Body: Ductile Iron; ASTM A536
iii Bolts: 316 stainless steel.
iv Coating: AWWA C550; interior/exterior.
v Pressure rating: meet or exceed adjacent piping system rating. vi System compatible with connecting pipe; verify connecting pipe O.D. b Restrained Flange Coupling Adaptor
i System: restrain plain end of pipe to a flange, conforming to AWWA C110. ii Body: Ductile Iron; ASTM A536
iii Bolts: 316 stainless steel,
iv Coating: AWWA C550; interior/exterior.
v Pressure rating: meet or exceed adjacent piping system rating. vi System compatible with connecting pipe; verify connecting pipe O.D. c Manufacturers:
i Ford - Ultra-Flex
ii Romac - XR501
iii Smith-Blair - Quantum Series
iv Hymax - 860 Series
v Substitutions: Section 01 60 00 - Product Requirements. 5 BOLTS FOR UNDERGROUND PIPING AND VALVES
a Bolts: ASTM A307, Grade B heavy hex head. External valve bolts and nuts shall be stainless steel Type 304 or better.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 225
SPECIFICATIONS
b Nuts: ASTM A563, heavy hex nuts. External valve bolts and nuts shall be stainless steel Type 304 or better.
c Plastic washers and sleeves for dielectric joints shall be provided. d All nuts and bolts shall have a fluoropolymer coating. Fluoropolymer coating for bolts and nuts shall be applied at a nominal thickness of 1 mil. and baked on. Coating shall have a minimum kinetic friction coefficient of 0.08. Coating shall be Tripac 2000 Blue Coating System, or approved equivalent.
6 RESTRAINED JOINTS
a Manufacturer:
i EBAA Iron - Series 2000PV Megalug.
ii Romac Industries, Inc. - Romagrip.
iii Substitutions: Section 01 60 00 - Product Requirements. b Materials: ductile iron, ASTM A536.
c Coating: Fusion bonded epoxy, MEGA-BOND or approved equivalent. d Pressure rating: minimum working pressure rating equivalent to the pipe. 7 SERVICE SADDLES
a City of Sebastopol Standard 864 & 863A.
b Materials: Bronze and stainless steel nylon coated of the double strap type. c Saddle shall be stamped for use with ductile iron pipe. d Manufacturer:
i Ford - 202BS, FC202, FS303
ii Jones - J 969 Series
iii McDonald – 3845, 3855
iv Mueller - DR 2 S Series, BR 2 S Series
v Romac - 202BS, 202NS
vi Smith-Blair 317, 393Substitutions: Section 01 60 00 - Product Requirements. 8 TAPPING SLEEVES
a Material: Cast Iron Stainless steel
b Sleeve must be compatible with pipe type.
c Manufacturers:
i Dresser: Style 630.
ii Ford: FTSS
iii JMC: 415
iv JCM: 432
v McDonald 3845, 3855
vi Mueller: H-304
vii Powerseal: 3490
viii Romac: SST111
ix Smith-Blair: 663, 664 & 665
x Substitutions: Section 01 60 00 - Product Requirements. 9 CORPORATION STOPS
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 226
SPECIFICATIONS
a Materials: Bronze no-lead alloy conforming to AWWA C800 and ASTM B62. b Manufacturer:
i Mueller: B-25008N
ii Ford: FB 1000-4-Q-NL - 1 ", FBl000-6-Q-NL - 1-1/2".
iii Jones: E -3401SG- 1", E19375SG - 1" & 1-1/2". .
iv McDonald: 74701BQ
v Substitutions: Section 01 60 00 - Product Requirements. 10 CURB STOPS
a Materials: Bronze no-lead alloy conforming to AWWA C800 and ASTM B62. b Manufacturer: Mueller B-24286.
c Substitutions: Section 01 60 00 - Product Requirements. 11 SERVICE PIPING AND FITTINGS
a Per City of Sebastopol Standard 864 & 863A.
b Piping Material (HDPE):
i Material: High Density Polyethylene per ANSI/AWWA C901 and ASTM D2737 -02 ii Size: Blue Copper Tubing Size (CTS) SDR 9
iii Pressure Class: PE3608 – 200 psi tubing or PE 4710 – 250 psi tubing c Piping Material (Copper)
i Type “K” hard temper copper
ii Materials: Per AWWA C800 and ASTMB88
d Size: ¾”, 1”. 1-1/2” Per Approved Plans.
12 SERVICE ELBOW
a Materials: Bronze no-lead alloy conforming to AWWA C800 and ASTM B62. b Manufacturer:
i Ford.
ii Jones
iii McDonald
iv Mueller H 15533.
v Substitutions: Section 01 60 00 - Product Requirements. 13 BLOW OFF - BALL VALVES
a Per City of Sebastopol Standards 861
b Manufacturer:
i Ford - B11-777W-NL
ii Jones - E-1900W
iii McDonald - 76101W
iv Mueller - B-20200N
v Substitutions: Section 01 60 00 - Product Requirements. 14 ANGLE BALL VALVES
a Per City of Sebastopol Standards 863-A and 864
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 227
SPECIFICATIONS
b Manufacturers:
i Ford - BA13-332W-NL, BA43-342W-Q-NL, BA43-444W-Q-NL-1” ii Jones - E-1966W, E-1963WSG
iii McDonald - 74604B, 74602BQ
iv Mueller - B-24265N, B-24258
v Substitutions: Section 01 60 00 - Product Requirements. 15 COMBINATION AIR VACUUM VALVE
a Manufacturer:
i APCO: 143C.
ii Crispin: UL10.
iii Valmatic: VM-201C
16 BUG SCREEN
a Manufacturer:
i Flow Ezy: “M8” Pipe mounted suction screen.
17 PIPE EMBEDMENT MATERIAL
a Unless otherwise specified or shown, all material used for pipe embedment shall be as specified in Section 31 23 00, “Trench Excavation and Backfill.” 18 VALVE BOXES
a Valve boxes:
i Manufacturer: Christy Model G5.
ii Substitutions: Section 01 60 00 - Product Requirements. 19 PIPE & JOINT SLEEVES
a Ductile iron or zinc coated steel.
b Mechanical Joint Solid Sleeve:
i Manufacturers:
1 Tyler Union
2 Star
3 Sigma
4 U.S. Pipe
20 TRACER WIRE
a Manufacturers:
i Pro-Line
ii Substitutions: Section 01600 - Product Requirements. b Characteristics:
i Type: THWN
ii Gage: No. 12
iii Materials: Copper conductor, PVC insulation, nylon jacket. 21 ACCESSORIES
a Non-shrink Grout: Specified in Section 03 30 00.
15 EXECUTION
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 228
SPECIFICATIONS
1 EXAMINATION
a Section 01 30 00 - Administrative Requirements: Verification of existing conditions before starting work.
b Verify existing utility water main size, location, and inverts are as indicated on Drawings. 2 PREPARATION
a Cut pipe ends square, ream pipe and tube ends to full pipe diameter, remove burrs. Use only equipment specifically designed for pipe cutting. Use of chisels or hand saws will not be permitted. Grind edges smooth with beveled end for push-on connections. b Remove scale and dirt on inside and outside before assembly. c Prepare pipe connections to equipment with flanges or unions. d Cutting of Asbestos Cement Pipe (ACP) shall be done utilizing a Pipe Cutter (snapper), of the proper type and size for intended use. A ratcheting hand snapper shall only be used on ACP sizes of 6 inch and smaller. The “snapper”, and all appurtenances shall have been inspected by the Contractor to ensure that it is in good working order prior to use. If field conditions require an alternative method for cutting of the ACP, the alternative method shall comply with all laws and requirements as specified by OSHA, the Contractor’s State Licensing Board, and any other governing body for this type of work. In all cases, cutting, handling, and disposal shall be done per the above stated governing bodies. Cut pipe shall be properly enclosed as soon as possible after removed from the trench.
3 BEDDING AND BACKFILL
a 2-inch to 12-inch Pipe
i Install bedding per plan.
ii Install backfill per plan.
4 INSTALLATION - PIPE
a Install pipe in accordance with manufacturer’s instructions and AWWA. b Maintain separation of water main from sewer piping in accordance with State of California Department of Public Health code or per the Plans.
c Install pipe to indicated elevation to within tolerance of 5/8 inches. d Route pipe in straight line.
e Install pipe with no high points. If field conditions arise which necessitate high points, install air release valves as directed by Engineer.
f Install pipe to have bearing along entire length of pipe. Excavate bell holes to permit proper joint installation. Do not lay pipe in wet or frozen trench. g Install pipe to allow for expansion and contraction without stressing pipe or joints. h Close pipe openings with watertight plugs during work stoppages. i Install access fittings to permit disinfection of water system. j Form and place concrete for thrust restraints at each elbow or change of direction of pipe main.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 229
SPECIFICATIONS
k Establish elevations of buried piping with not less than 4 feet of cover. Measure depth of cover from final surface grade to top of pipe barrel.
l Install pipe warning tape continuous over top of pipe buried 6 inches below finish grade, above pipe line.
5 INSTALLATION - VALVES
a Gate Valves: Install valves per Plan.
b Set valves on solid bearing compacted soil.
c Center and plumb valve box over valve. Set box cover flush with finished grade. 6 POLYETHYLENE ENCASEMENT
a Encase ductile iron fittings in polyethylene to prevent contact with surrounding backfill material.
b Install in accordance with AWWA C105.
c Terminate encasement 3 to 6 inches above ground where pipe is exposed. 7 PIPE SLEEVES:
a Install where water lines pass through retaining walls, building foundations and floors. Seal with modular mechanical type link seal. Install piping so that no joint occurs within a sleeve. Split sleeves may be installed where existing lines pass through new construction. 8 THRUST RESTRAINT
a Install clamps, set screw retainer glands, or restrained joints. Protect metal restrained joint components against corrosion by applying a bituminous coating, or by concrete mortar encasement of metal area. Do not encase pipe and fitting joints to flanges. 9 BACKFILLING
a Backfill around sides and to top of pipe per trench detail in the Plan. b Maintain optimum moisture content of bedding material to attain required compaction density.
10 DISINFECTION OF POTABLE WATER PIPING SYSTEM
a Flush and disinfect system in accordance with Section 33 13 00. 11 FIELD QUALITY CONTROL
a Section 01 40 00 - Quality Requirements: Field inspecting, testing, adjusting, and balancing. b Compaction Requirements: In accordance with Section 31 23 00. c When tests indicate Work does not meet specified requirements, remove Work, replace and retest at the Contractor’s expense.
12 PRESSURE TESTING
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 230
SPECIFICATIONS
a Prior to acceptance of the Work by the City, the Contractor shall perform pressure testing on potable water distribution systems in accordance with City Standards and:
i AWWA C600 for ductile iron pipe.
ii AWWA C605 for PVC pipe.
iii AWWA C901 for Polyethylene pressure pipe.
b When tests indicate Work does not meet specified requirements, remove Work, replace and retest at the Contractor’s expense.
END OF SECTION
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 231
SPECIFICATIONS
THIS PAGE LEFT INTENTIONALLY BLANK
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 232
SPECIFICATIONS
SECTION 33 13 00
DISINFECTING OF WATER UTILITIES
PART 51 GENERAL
1.1 SUMMARY
A. Section includes disinfection of potable water systems and tanks; and testing and reporting results.
B. Related Sections:
1. Section 33 11 00 – Water Utilities.
1.2 REFERENCES
A. City of Sebastopol Standards.
B. City of Santa Rosa Water Standard Specifications (Section 132).
C. American Water Works Association:
1. AWWA B301 - Liquid Chlorine.
2. AWWA C651 - Disinfecting Water Mains.
1.3 SUBMITTALS
A. Submit all product data, shop drawings, laboratory test results, material source information, and certificates of compliance listed in this Section under a single submittal cover for review.
Incomplete submittals will not be reviewed.
B. Section 01 33 00 - Submittal Procedures: Requirements for submittals.
C. Disinfection Procedure: Submit procedure description including type of disinfectant and calculations indicating quantities of disinfectants required to produce specified chlorine concentration in accordance with Section 4 of AWWA C651. Submit proposed water disposal and de-chlorination procedure.
D. Product Data: Submit procedures, proposed chemicals, and treatment levels for review.
E. Test Reports: Indicate results comparative to specified requirements.
F. Certificate: Certify cleanliness of water distribution and storage system meets or exceeds specified requirements.
1.4 CLOSEOUT SUBMITTALS
A. Section 01 70 00 - Execution and Closeout Requirements: Requirements for submittals.
B. City will collect samples for disinfection residual testing. Reporting may include:
1. Type and form of disinfectant used.
2. Date and time of disinfectant injection start and time of completion.
3. Test locations.
4. Name of person collecting samples.
5. Initial and 24-hour disinfectant residuals in treated water in ppm for each outlet tested.
6. Date and time of flushing start and completion.
7. Disinfectant residual after flushing in ppm for each outlet tested.
C. City will collect samples for bacteriological testing. Reporting may include:
1. Date issued, project name, and testing laboratory name, address, and telephone number.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 233
SPECIFICATIONS
2. Time and date of water sample collection.
3. Name of person collecting samples.
4. Test locations.
5. Initial and 24 hour disinfectant residuals in ppm for each outlet tested.
6. Coliform bacteria test results for each outlet tested.
7. Certify water conforms, or fails to conform, to bacterial standards of authority having jurisdiction.
D. Water Quality Certificate: City will verify water conforms to quality standards of authority having jurisdiction, suitable for human consumption.
1.5 QUALITY ASSURANCE
A. Perform Work in accordance with AWWA C651.
B. Neutralize disinfectant solution and chlorinated water before disposal.
C. Legally dispose of disinfection solution and chlorinated water .
D. Repair damage caused by disinfectant solution and disinfection procedures.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Section 01 60 00 - Product Requirements : Requirements for transporting, handling, storing, and protecting products.
B. Store disinfectants in cool, dry place away from combustibles such as wood, rags, oils and grease.
C. Handle disinfectants with caution; protect skin and eyes from contact; avoid breathing vapors; wear gloves, aprons, goggles, and vapor masks.
PART 52 - PRODUCTS
1.1 DISINFECTION CHEMICALS
A. Chlorine Forms: In accordance with AWWA C651, Section 4.
PART 53 - EXECUTION
1.1 EXAMINATION
A. Section 01 30 00 - Administrative Requirements: Verification of existing conditions before starting work.
B. Verify piping system has been cleaned, inspected, and pressure tested and accepted.
C. Perform scheduling and disinfecting activity with start-up, water pressure testing, adjusting and balancing, demonstration procedures, including coordination with related systems.
1.2 APPLICATION
A. Provide and attach required equipment to perform the Work of this section.
B. Comply with California Department of Public Health Disinfection Requirements.
C. Perform disinfection of water distribution system during installation of system and pressure testing.
Refer to Section 33 11 00.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 234
SPECIFICATIONS
D. Introduce treatment into piping system.
E. Maintain disinfectant in system for 24 hours.
F. Dechlorinate, flush, circulate, and clean until required cleanliness is achieved; use municipal domestic water.
G. Replace permanent system devices removed for disinfection.
1.3 FIELD QUALITY CONTROL
A. Section 01 40 00 - Quality Requirements: Field inspecting, testing, adjusting, and balancing.
B. Pipeline Disinfection, Flushing, and Sampling:
1. Disinfect pipeline installation in accordance with AWWA C651.
2. Upon completion of retention period required for disinfection, flush pipeline until chlorine concentration in water leaving pipeline is no higher than that generally prevailing in existing system or is acceptable for domestic use.
3. Legally dispose of chlorinated water. When chlorinated discharge may cause damage to environment, apply neutralizing chemical to chlorinated water to neutralize chlorine residual remaining in water.
4. After final flushing and before pipeline is connected to existing system, or placed in service, request City to sample, test and certify water quality suitable for human consumption. Do not proceed with pipeline connection work until test is certified and City authorizes work to proceed.
END OF SECTION
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 235
SPECIFICATIONS
THIS PAGE INTENTIONALLY LEFT BLANK
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 236
SPECIFICATIONS
SECTION 33 31 00
SANITARY UTILITY SEWERAGE PIPING
PART 4 GENERAL
4.01. SUMMARY
A. Section Includes:
1. PVC sanitary sewage pipe.
2. Underground pipe markers.
3. Bedding and cover materials.
B. Related Sections:
1. Section 31 00 00 - Earthwork.
2. Section 33 05 13 – Manholes
3. Division 2
4.02. REFERENCES
A. American Association of State Highway and Transportation Officials:
1. AASHTO T180 - Standard Specification for Moisture-Density Relations of Soils Using a 10-lb Rammer and a 18-in. Drop.
B. ASTM International:
1. ASTM D698 - Standard Test Method for Laboratory Compaction Characteristics of Soil Using Standard Effort (12,400 ft-lbf/ft3).
2. ASTM D1557 - Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56,000 ft-lbf/ft3).
3. ASTM D2321 - Standard Practice for Underground Installation of Thermoplastic Pipe for Sewers and Other Gravity-Flow Applications.
4. ASTM D2729 - Standard Specification for Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings.
5. ASTM D2751 - Standard Specification for Acrylonitrile-Butadiene-Styrene (ABS) Sewer Pipe and Fittings.
6. ASTM D2922 - Standard Test Method for Density of Soil and Soil-Aggregate in Place by Nuclear Methods (Shallow Depth).
7. ASTM D3017 - Standard Test Method for Water Content of Soil and Rock in Place by Nuclear Methods (Shallow Depth).
8. ASTM D3034 - Standard Specification for Type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings.
9. ASTM F477 - Standard Specification for Elastomeric Seals (Gaskets) for Joining Plastic Pipe.
C. Others specified
4.03. DEFINITIONS
A. Bedding: Fill placed under, beside and directly over pipe, prior to subsequent backfill operations.
4.04. SUBMITTALS
A. Section 01 33 00 - Submittals: Requirements for submittals.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 237
SPECIFICATIONS
B. Submit all product data, shop drawings, laboratory test results, leakage testing details including testing equipment, material source information, and certificates of compliance listed in this Section under a single submittal cover for review. Incomplete submittals will not be reviewed.
C. Materials List
1. In accordance with the provisions of Section 01 33 0 “Submittal Procedures” of the Specifications, submit with the shop drawings a complete list of all materials and equipment proposed to be furnished and installed under this portion of the work, giving manufacturer's name, catalog number, and catalog cuts for each item where applicable.
2. The Contractor shall use a single manufacturer for each of the following types of items unless otherwise approved by the Engineer.
• Pipe
• Fittings
• Lateral cleanout plug
D. Manufacturer's Installation Instructions: Indicate special procedures required to install Products specified.
E. Testing Certifications:
1. Leakage Testing
F. Bypass pumping and/or diversion system plan (if required). This shall include temporary documentation of pump and discharge line capacities, manufacturer, and age. Bypass pumping plan shall also include shop drawings that identify pumping locations and methods with sufficient detail to assure that the work can be accomplished without sewage spills. The plans shall include an emergency discharge response plan to be followed in the event of a failure of the bypass pumping system.
4.05. CLOSEOUT SUBMITTALS
A. Section 01 70 00 – Project Closeout: Requirements for submittals.
B. Project Record Documents: Record location of pipe runs, connections, manholes, cleanouts, and invert elevations.
C. Identify and describe unexpected variations to subsoil conditions or discovery of uncharted utilities.
4.06. QUALITY ASSURANCE
A. Perform Work in accordance with City Standard Plans.
B. Perform Work in accordance with City of Santa Rosa Sanitary Sewer Standard Specifications (Section 130).
4.07. FIELD MEASUREMENTS
A. Verify field measurements and elevations are as indicated.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 238
SPECIFICATIONS
4.08. COORDINATION
A. Section 01 30 00 - Administrative Requirements: Coordination and project conditions.
PART 5 PRODUCTS
5.01. SANITARY SEWAGE PIPE
A. Color: Green
B. Gravity PVC Laterals and Mains (size 4-inch and larger): ASTM D3034 and ASTM F-679, Poly (Vinyl Chloride) (PVC) material; inside nominal diameter as specified on the Drawings, bell and spigot style rubber ring sealed gasket joint.
1. Fittings: SDR 26 gasketed type. Flexible transition couplers shall have stainless steel shear bands. Lateral bends from cleanout to main shall be gasket x spigot long radius bends
2. Joints: ASTM F477 & ASTM D-3139, elastomeric gaskets.
3. Diameter ratio: SDR 26
4. Size: Per plans. All laterals shall be 6” unless otherwise specified.
C. Risers
1. (Size 4” and 6”) shall be SDR 35 or 26
D. Manufacturers:
1. JM Manufacturing Co. or JM Eagle is not acceptable.
5.02. RESTRAINED AND MECHANICAL JOINTS
A. Manufacturer:
1. For PVC Pipe:
a. Mechanical Joint Fittings: EBAA Iron, Inc., Series 2000PV or equivalent.
2. Substitutions: Section 01 60 00 - Product Requirements.
B. Materials: ASTM D-2241.
C. Joints: Gasketed, meeting ASTM D-3139 and ASTM F-477
5.03. COUPLINGS
A. Manufacturers
1. a. APAC - 300 Series
b. Dresser - Style 253
c. Ford - Ultra-Flex
d. Romac - 501 Series
e. Smith-Blair -Quantum Series
2. Substitutions: Section 01 60 00 - Product Requirements.
B. System compatible with connecting pipe; verify connecting pipe O.D.
5.04. CLEANOUT PLUGS
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 239
SPECIFICATIONS
A. Cleanout plugs shall be installed on all cleanouts and conform with City of Sebastopol Standard Detail 513 and 513A
B. Manufacturers:
1. IPS/Test-Tite Flush Mount T-Cone Plug - 4" - S 401, 6" - S 601
2. Cherne Industries "Original" End of Pipe Gripper
C. CLEANOUT BOX
1. Cleanout plugs shall be installed on all cleanouts and conform with City of Sebastopol Standard Detail 513 and 513A
2. Manufacturers:
Cleanout Box - 4” (Lid marked “SEWER”)
a. D & L Supply - M-8030
b. Geneco - CC4
c. South Bay Foundry - B5230
Cleanout Box - 6”
d. Genco – CC6
5.05. BEDDING AND COVER MATERIALS
A. Bedding: Fine Aggregate Fill as specified in Section 31 00 00.
B. Soil Backfill from Above Pipe to Finish Grade: Select Fill Soil Type, as specified in Section 31 00 00.
PART 6 EXECUTION
6.01. EXAMINATION
A. Section 01 30 00 - Administrative Requirements: Verification of existing conditions before starting work.
B. Verify trench cut is ready to receive work and excavations, dimensions, and elevations are as indicated on drawings.
6.02. PREPARATION
A. Correct over excavation with fine aggregate.
B. Remove large stones or other hard matter which could damage pipe or impede consistent backfilling or compaction.
C. Prior to the installation of each new individual sewer wye on the main, the Contractor shall determine the exact location of the existing sewer lateral at the back of sidewalk or PUE. Two acceptable methods of locating a sewer lateral at the back of sidewalk are.
1. Removing sidewalk and/or potholing by hand digging at the back of sidewalk to locate the existing lateral pipe a minimum of 24 hours prior to sewer main installation in that area.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 240
SPECIFICATIONS
2. Inserting a metallic electricians “fish tape” into the existing lateral pipe after the pipe is exposed during sewer main excavation and tracing the “fish tape” to the back of sidewalk using a pipe and cable metal locator. If this method does not locate the existing sewer lateral, method “1” shall be used.
D. All existing pipe impeding the construction of new laterals shall be removed per specification Section 02 41 10 and 02 01 10.
6.03. BEDDING
A. Excavate pipe trench in accordance with Section 31 23 00.
B. Place bedding material at trench bottom, level materials in continuous layer not exceeding 6 inches.
C. Maintain optimum moisture content of bedding material to attain required compaction density.
6.04. INSTALLATION - PIPE
A. Install pipe, fittings, and accessories in accordance with City of Sebastopol Standard Details and City of Santa Rosa Sewer Construction Specifications (Section 130). Seal joints watertight.
B. Lay pipe to slope gradients noted on drawings to meet join existing property side laterals; with maximum variation from indicated slope of 1/8 inch in 10 feet. Pipe shall be installed at continuous slope as shown on drawings.
C. Excavate bell holes to permit proper joint installation.
D. Install pipe to have bearing along entire length of pipe.
E. Install bedding at sides and over top of pipe to minimum compacted thickness of 6 inches.
F. Cover is the distance from the top of the pipe to the final finished grade measured directly over the pipe.
G. Minimum cover for all sewer mains and laterals shall be 36”. The Engineer may approve shallower installations but in no case shall cover be less than 24”.
H. Where cover is less than 36”, special construction techniques must be approved such as the use of ductile iron pipe, a concrete cap over the trench, or the use of control density backfill.
I. Refer to Section 31 23 00 for backfilling and compacting requirements. Do not displace or damage pipe when compacting.
J. Install all sewer laterals perpendicular to the curb unless otherwise shown per plan.
1. Any lateral not installed perpendicular to the curb shall installer tracer wire (material & type per Section 33 11 00) in the following manner, unless otherwise shown on drawings and details:
a. Wrap wire two times around wye connection at main and secure. b. Lay both ends on top of and along the lateral to the cleanout and up the cleanout riser. Both ends of the wire shall extend approximately 6 inches beyond riser.
c. Secure wire to top of lateral pipe at approximately 5 foot intervals. Ends of wire must be easily accessible inside the cleanout box.
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 241
SPECIFICATIONS
K. Install plastic ribbon tape continuous over top of pipe buried 12 inches below finish grade, above pipe line; coordinate with Section 31 23 00.
6.05. TESTING OF SEWERS
A. Test for leakage shall be performed for all portions of the sewer, including manholes, is required.
1. All testing required shall conform with the City of Santa Rosa Sewer Construction Specification 130-1.08
B. All new or rehabilitated sanitary sewer manholes shall be tested unless otherwise directed by the Engineer. If the manhole fails the test, the manhole shall be repaired and retested at the contractor’s expense. If manhole joint sealants are compromised during the vacuum test, the manhole must be disassembled and the joint sealants replaced. If there is reason to believe that the manhole has been disturbed after the initial vacuum test, additional tests may be requested by the Engineer and performed at the Contractor’s expense.
1. Leakage Testing:
a. Water Test: Manholes, after inlets and outlets have been plugged, shall be filled with water to the rim of the frame casting and shall lose no more than 2 inches over a period of 30 minutes.
b. Vacuum Testing shall be performed in accordance with ASTM C 1244-20.
Vacuum testing shall not take place until all permanent paving is complete. 1) All lift holes and joints shall be grouted and the entire manhole, including grade rings, sealed prior to testing.
2) All pipes entering the manhole shall be temporarily plugged, taking care to securely brace the pipes and plugs to prevent them from being drawn into the manhole.
3) The test head shall be placed in accordance with the manufacturer’s recommendations. The test unit shall be braced against the manhole frame and not the grade ring(s) or taper.
4) Vacuum test gauge and test equipment used for this test shall be supplied by the Contractor and shall be operated per manufacturer’s specifications by qualified personnel. Accuracy and calibration of the guage shall be certified by a reliable testing firm at 6 month intervals, or when requested by the Engineer.
5) A vacuum of 10 inches HG (4.91 PSI) of mercury shall be drawn on the manhole, the valve on the vacuum line of the test head closed, and the vacuum pump shut off. The time it takes the indicator gauge to drop from 10 inches HG (4.91) to 9 inches Hg (4.4 PSI) shall be measured. The manhole will pass the vacuum test if the time is greater than shown in the following table:
6) After the vacuum test, manholes shall be visually inspected for leaks and defects and repaired as required by the engineer
c. Exfiltration or Infiltration testing
Agenda Item Number 6
Agenda Item Number 6
City Council Meeting Packet for February 21, 2023
PART 3 - 242
SPECIFICATIONS
2. Installation of vacuum equipment and indicating devices must be in accordance with the manufacturer’s recommendations and performance specifications, which must be provided by the manufacturer and approved by the Engineer. The equipment must be capable of testing the entire manhole, including cast iron frame and grade adjustment rings.
6.06. BYPASS PUMPING AND/OR DIVERSION SYSTEM
A. Bypass pumping shall be performed per the City of Santa Rosa Sewer Specification 130-1.10 B. Contractor shall allow up to 10 working days for response from the City and Engineer for any request regarding sewer flows.
6.07. FIELD QUALITY CONTROL
A. Section 01 40 00 - Quality Requirements: Field inspecting, testing, adjusting, and balancing.
B. Compaction Requirements: In accordance with Section 31 23 00.
C. When tests indicate Work does not meet specified requirements, remove work, replace and retest.
6.08. PROTECTION OF FINISHED WORK
A. Section 01 70 00 -Project Closeout: Requirements for protecting finished Work.
B. Protect pipe and aggregate cover from damage or displacement until backfilling operation is in progress.
END OF SECTION