PHASE 1 PRECISE PLAN PACKAGE - ALTERNATIVE D PUBLIC REVIEW DRAFT C 2022 RE- SUBMITTAL DATE 05.06.22 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 VICINITY MAPS SHEET INDEX PROJECT SITE HIGHWAY 101
INTERSTATE 380 INTERSTATE 280
DOLLAR AVE PROJECT SITE TANFORAN AVE MAPLE AVE HIGHWAY 101 INTERSTATE 380
Vicinity Maps & Sheet Index A1 PHASE 1 - PROJECT DATA – – –
TANFORAN AVENUE DOLLAR AVENUE
LINDEN AVENUE
MAPLE AVENUE
Existing
Building
Existing
Building
Existing
Building
Existing
Building
Existing
Building
Existing
Building
Existing
Building
Existing
Building
Existing
Building
Existing
Building
Existing
Building
Existing
Building SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 Existing Site Plan A2 UP Bldg 1 318,380 sf 6 stories +26 FF Bldg 7 296,620 sf 6 stories +24 FF Bldg 2 - Amenities 69,710 sf 1 story above 2 level parking +28 FF MOBILITY HUB RIDE SHARE PSD S+5 levels +23.5 FF FUTURE IMPROVEMENTS NEW ROAD
MAPLE AVE
LINDEN AVE TANFORAN AVE DOLLAR AVE COMMUNITY CENTER FOOD AND BEVERAGE L NEW ROAD L L GEN. PARKING 29'-4" 41'-4" 47'-3" 71'-1" 26'-0" 26'-0" 62'-2" 60'-10" 54'-0"
24'-2"
`25'-8"
30'-0" 30'-0" 30'-0"
39'-5"
99'-5" SERVICE YARD SCREEN WALL ENTRY PLAZA TERRACED PLAZA BIKE KIOSK TANFORAN PARKLET FIRE ACCESS LANE NEW SIDEWALK FIRE PUMP GEN. FUTURE EQPT. FUTURE STOR. B1 TRASH B2 TRASH FIRE B7 TRASH PUMP FUTURE STOR. FUTURE EQPT. TANFORAN PARKLET 4 RIDE SHARE STALLS 47'-3"
47'-5"
30'-6"
28'-6" FIRE ACCESS LANE EXISTING PROPERTY LINE AREA OF WORK PROPOSED PARCEL LINES Proposed Site Plan (Phase 1 Site Plan) A3 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 PRIMARY ACCESSIBLE FACADE (15'-0" to 30'-0") SECONDARY ACCESSIBLE FACADE FIRE TRUCK LANDING ZONE (26' WIDE MINIMUM) SOUTHLINE SITE PLAN FIRE COMMAND ROOM Bldg 1: 6 stories Bldg 7: 6 stories Bldg 2 -Amenities 1 Story above 2 level parking FUTURE IMPROVEMENTS NEW ROAD TANFORAN AVE DOLLAR AVE
LINDEN AVE
MAPLE AVE HUNTINGTON AVE NEW ROAD PSD: Surface + 5 Levels UP 26'-11" 30'-0" 47'-6"
47'-3" 41'-4" 8'-3" 29'-4" 28'-6"
24'-2"
30'-0"
47'-3"
47'-5"
25'-8" SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 Fire Access Site Plan A4 +28.0 B1 B2 B7 PS-D +26.0 +26.0 +24.0 +28.0 +26.0 +23.5 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 Conceptual Site Sections A5 North to South Section: Building 1 A Key Plan North to South Section: Amenities Building B West to East Section: Buildings 1 and 7 C West to East Section: Amenities Building, Building 1, and Parking Structure D D 16 17 18 19 20 KNPRT X16 X17 X17.8 X19 X20 XD XB XF XG XH JU 16.6 17.2 17.9 18.3 19.2 19.4 X16.3 X18.7 XB.2 X19.7 X18 L XG.2 XF.6 28'-0" 5'-0" 14'-8" 18'-4" 33'-0" 31'-0" 2'-0" FIRE COMMAND 21'-0" 27'-1" 15'-0" 23'-0" 7'-0" 30'-0" 30'-0" 8'-0" 161'-1" 132'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 16'-6"
214'-6"
26'-0" 12'-0"
5'-0 1/2"
30'-0"
1'-11 1/2"13'-0 1/2" 24'-11 1/2" 5'-0 1/2"17'-0 1/2" 26'-0" 161'-1" STAIR 1 VEST. ELEC IDF WOMEN MEN JAN STAIR 2 VEST. VEST. STAIR 3 IDF ELEC ELECTRICAL SUBSTATION AHU PGE EMERGENCY ELECTRICAL MPOE DW PUMP ROOM LOADING DOCK LOBBY TENANT SPACE ELEV. CONTROL FIRE WATER PUMP GENERATOR ENCLOSURE ENTRY CANOPY ABOVE CANOPY ABOVE FIRE TANK BELOW SERVICE ELEV. 16 17 18 19 20 KNPRT X16 X17 X17.8 X19 X20 XD XB XF XG XH JU 16.6 17.2 17.9 18.3 19.2 19.4 X16.3 X18.7 XB.2 X19.7 X18 L XG.2 XF.6 TENANT SPACESTAIR 1 VEST. ELEC IDF WOMEN MEN STAIR 2 VEST. VEST. STAIR 3 IDF ELEC SERVICE ELEV. SERVICE ELEV. VEST. JAN 28'-0" 5'-0" 14'-8" 18'-4" 33'-0" 31'-0" 2'-0" 21'-0" 27'-1" 15'-0" 23'-0" 7'-0" 30'-0" 30'-0" 8'-0" 161'-1" 132'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 16'-6"
214'-6" ENTRY CANOPY BELOW LINE OF FLOOR ABOVE 26'-0" 12'-0" 5'-0 1/2"
30'-0"
1'-11 1/2"13'-0 1/2" 24'-11 1/2" 5'-0 1/2"17'-0 1/2" 26'-0" 161'-1" B1 B2 B7 PSD Building 1 Floor Plans - Levels 1 and 2 A6 1 2 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" Building 1: Floor Plan Level 2 1" = 20'-0" Building 1: Floor Plan Level 1 16 17 18 19 20 KNPRT X16 X17 X17.8 X19 X20 XD XB XF XG XH JU 16.6 17.2 17.9 18.3 19.2 19.4 X16.3 X18.7 XB.2 X19.7 X18 L XG.2 XF.6 TENANT SPACESTAIR 1 VEST. ELEC IDF WOMEN MEN STAIR 2 VEST. VEST. STAIR 3 IDF ELEC SERVICE ELEV. SERVICE ELEV. VEST. JAN 28'-0" 5'-0" 14'-8" 18'-4" 33'-0" 31'-0" 2'-0" 21'-0" 27'-1" 15'-0" 23'-0" 7'-0" 30'-0" 30'-0" 8'-0" 161'-1" 132'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 16'-6"
214'-6" BALCONY BALCONY 26'-0" 12'-0"
5'-0 1/2"
30'-0"
1'-11 1/2"13'-0 1/2" 24'-11 1/2" 5'-0 1/2"17'-0 1/2" 26'-0" 161'-1" BALCONY 16 17 18 19 20 KNPRT X16 X17 X17.8 X19 X20 XD XB XF XG XH JU 16.6 17.2 17.9 18.3 19.2 19.4 X16.3 X18.7 XB.2 X19.7 X18 L XG.2 XF.6 TENANT SPACESTAIR 1 VEST. ELEC IDF WOMEN MEN STAIR 2 VEST. VEST. STAIR 3 IDF ELEC SERVICE ELEV. SERVICE ELEV. VEST. JAN 28'-0" 5'-0" 14'-8" 18'-4" 33'-0" 31'-0" 2'-0" 21'-0" 27'-1" 15'-0" 23'-0" 7'-0" 30'-0" 30'-0" 8'-0" 161'-1" 132'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 16'-6"
214'-6"
26'-0" 12'-0"
5'-0 1/2"
30'-0"
1'-11 1/2"13'-0 1/2" 24'-11 1/2" 5'-0 1/2"17'-0 1/2" 26'-0" 161'-1" B1 B2 B7 PSD 1 2 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Building 1 Floor Plans - Levels 3 and 4 Re-Submittal #5 05.06.2022 A6.1 1" = 20'-0" Building 1: Floor Plan Level 4 1" = 20'-0" Building 1: Floor Plan Level 3 16 17 18 19 20 KNPRT X16 X17 X17.8 X19 X20 XD XB XF XG XH JU 16.6 17.2 17.9 18.3 19.2 19.4 X16.3 X18.7 XB.2 X19.7 X18 L XG.2 XF.6 TENANT SPACESTAIR 1 VEST. ELEC IDF WOMEN MEN STAIR 2 VEST. VEST. STAIR 3 IDF ELEC SERVICE ELEV. SERVICE ELEV. VEST. JAN 28'-0" 5'-0" 14'-8" 18'-4" 33'-0" 31'-0" 2'-0" 21'-0" 27'-1" 15'-0" 23'-0" 7'-0" 30'-0" 30'-0" 8'-0" 161'-1" 132'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 16'-6"
214'-6"
26'-0" 12'-0"
5'-0 1/2"
30'-0"
1'-11 1/2"13'-0 1/2" 24'-11 1/2" 5'-0 1/2"17'-0 1/2" 26'-0" 161'-1" 16 17 18 19 20 KNPRT X16 X17 X17.8 X19 X20 XD XB XF XG XH JU 16.6 17.2 17.9 18.3 19.2 19.4 X16.3 X18.7 XB.2 X19.7 X18 L XG.2 XF.6 TENANT SPACESTAIR 1 VEST. ELEC IDF WOMEN MEN STAIR 2 VEST. VEST. STAIR 3 IDF ELEC SERVICE ELEV. SERVICE ELEV. VEST. JAN 28'-0" 5'-0" 14'-8" 18'-4" 33'-0" 31'-0" 2'-0" 21'-0" 27'-1" 15'-0" 23'-0" 7'-0" 30'-0" 30'-0" 8'-0" 161'-1" 132'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 16'-6"
214'-6"
26'-0" 12'-0"
5'-0 1/2"
30'-0"
1'-11 1/2"13'-0 1/2" 24'-11 1/2" 5'-0 1/2"17'-0 1/2" 26'-0" 161'-1" B1 B2 B7 PSD Building 1 Floor Plans - Levels 5 and 6 A6.2 1 2 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" Building 1: Floor Plan Level 6 1" = 20'-0" Building 1: Floor Plan Level 5 16 17 18 19 20 KNPRT X16 X17 X17.8 X19 X20 XD XB XF XG XH JU 16.6 17.2 17.9 18.3 19.2 19.4 X16.3 X18.7 XB.2 X19.7 X18 L XG.2 XF.6 28'-0" 5'-0" 14'-8" 18'-4" 33'-0" 31'-0" 2'-0" 21'-0" 27'-1" 15'-0" 23'-0" 7'-0" 30'-0" 30'-0" 8'-0" 161'-1" 132'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 16'-6"
214'-6" MECHANICAL PENTHOUSE MECHANICAL PENTHOUSE MECHANICAL EQUIPMENT AREA MECHANICAL EQUIPMENT AREA ROOF AREA 26'-0" 12'-0" 5'-0 1/2"
30'-0"
1'-11 1/2"13'-0 1/2" 24'-11 1/2" 5'-0 1/2"17'-0 1/2" 26'-0" 161'-1" EXHUAST STACKS - 4' DIAMETER, 3'-8" ABOVE MECH. SCREEN B1 B2 B7 PSD Building 1 Roof Plan A6.3 1 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" Building 1:Roof Plan L N P R T HIGH PERFORMANCE VISION GLASS W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE SPANDREL GLASS W/ ALUM. MULLION SYSTEM XB XB.2 XD XF XG METAL PANEL SUNSHADES TYPE 2 - BRONZE COLOR TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) TEXTURED ACCENT TERRA COTTA BAND METAL PANEL BRONZE COLOR VERTICAL METAL PANEL TRIM BRONZE COLOR RIBBED METAL PANEL TYPE 1 - BRONZE COLOR RIBBED METAL PANEL TYPE 2 - BRONZE COLOR FLAT BAR RAILING AT BALCONIES METAL LOUVERS TYPE 1 - BRONZE COLOR EXHAUST STACKS U SCREEN FOR COOLING TOWER SPANDREL GLASS W/ ALUM. MULLION SYSTEM TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) VERTICAL METAL PANEL TRIM BRONZE COLOR METAL PANEL CANOPY BRONZE COLOR HIGH PERFORMANCE VISION GLASS TYPE 1 W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE SPANDREL GLASS W/ ALUM. MULLION SYSTEM X20 X19 X18.7 X18 X17 X16.3 X16 HIGH PERFORMANCE VISION GLASS TYPE 2 W/ ALUM. MULLION SYSTEM METAL SUNSHADES TYPE 1 - BRONZE COLOR METAL PANEL BRONZE COLOR RIBBED METAL PANEL TYPE 1 - BRONZE COLOR RIBBED METAL PANEL TYPE 2 - BRONZE COLOR TEXTURED ACCENT TERRA COTTA BAND X19.7 X17.8 EXHAUST STACKS 1" = 20'-0" North Elevation 1 1" = 20'-0" West Elevation 2 1 2 Building 1 Exterior Elevations A7 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 HIGH PERFORMANCE VISION GLASS W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE SPANDREL GLASS W/ ALUM. MULLION SYSTEM 16 17 18 19 20 METAL PANEL SUNSHADES TYPE 2 - BRONZE COLOR 16.6 17.2 18.3 19.2 19.4 TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) TEXTURED ACCENT TERRA COTTA BAND METAL LOUVERS TYPE 1 - BRONZE COLOR RIBBED METAL PANEL TYPE 1 - BRONZE COLOR RIBBED METAL PANEL TYPE 2 - BRONZE COLOR 17.9 SPANDREL GLASS W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE VISION GLASS W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE SPANDREL GLASS W/ ALUM. MULLION SYSTEM METAL PANEL SUNSHADES TYPE 2 - BRONZE COLOR T R P N L K J XH XG XF XD XB.2 XB RIBBED METAL PANEL TYPE 1 - BRONZE COLOR METAL LOUVERS TYPE 2 - BRONZE COLOR TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) TEXTURED ACCENT TERRA COTTA BAND METAL PANEL BRONZE COLOR VERTICAL METAL PANEL TRIM BRONZE COLOR METAL PANEL CANOPY BRONZE COLOR METAL LOUVERS TYPE 1 - BRONZE COLOR RIBBED METAL PANEL TYPE 2 - BRONZE COLOR ROLL-UP DOOR FOR TRUCK LOADING U XG.2 XF.6 1" = 20'-0" South Elevation 1 1" = 20'-0" East Elevation 2 2 1 Building 1 Exterior Elevations A7.1 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 S 1 2 3 4 5 6 7 8 1010 1111 1212 MQ XC XE X1.4 X2 X3 X4 X5 X6 X7 X8 X9 X10 U X1 9 N 3'-0" COMMUNITY CENTER AGR ELEC. ROOM AGR BIKE KIOSK CONFERENCE DINING A.V. / STORAGE VEST. STAGING TRASH & WASH 32'-3" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 12'-4" 7'-10" 262'-5" 38'-0" 48'-6" 30'-0" 45'-6"
162'-0"
16'-8" 30'-0" 30'-0" 30'-0" 32'-6" 32'-6" 32'-6" 32'-6" 32'-6" 32'-6" 30'-0" 331'-8"
32'-6" 30'-0"
62'-6"
44'-0" ENTRY CANOPY ABOVE ENTRY CANOPY ABOVE MEN WOMEN STAIR 2 MPOE ENTRY CANOPY ABOVE FOOD AND BEVERAGE 25'-0" PARKING LEVEL 130'-6" UP STAIR 1 STAIR 4 STAIR 3 EMERGENCY POWER BIKE ENCLOSURE DOMESTIC WATER PUMP LOBBY B1 B7 PSD B2 A8 1 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" Building 2: Floor Plan Level 1 Building 2 Floor Plans - Level 1 S 1 2 3 4 5 6 7 8 1010 1111 1212 MQ XC XE X1.4 X2 X3 X4 X5 X6 X7 X8 X9 X10 U X1 9 N STAIR 1 STORAGE STORAGE LOBBY 38'-0" 48'-6" 30'-0" 45'-6"
162'-0"
32'-3"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
12'-4" 7'-10"
262'-5"
16'-8" 30'-0" 30'-0" 30'-0" 32'-6" 65'-0" 32'-6" 32'-6" 32'-6" 30'-0" 331'-8" ENTRY CANOPY BELOW OPEN TO BELOW OPEN TO BELOW PARKING LEVEL 2 DN. 25'-0"
25'-0"
30'-2" STAIR 4 STAIR 3 STAIR 2 B1 B7 PSD B2 Building 2 Floor Plans - Level 2 A8.1 1 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" Building 2: Floor Plan Level 2 UP S 1 2 3 4 5 6 7 8 1010 1111 1212 MQ XC XE X1.4 X2 X3 X4 X5 X6 X7 X8 X9 U X1 9 N MULTI-SPORT SIMULATOR BAR/ LOUNGE LOBBY STAIR 1 OFF 1 OFF 2 AGR STAIR 2 BREAK MENS LOCKERS STEAM LAUNDRY JAN. STEAM BAR LOUNGE BOH MEN WOMEN MANAGEMENT CONF BREAK WOMENS LOCKERS GROUP EXERCISE YOGA STORAGE YOGA FITNESS TERRACE BAR/LOUNGE TERRACE 162'-0"
38'-0" 48'-6" 30'-0" 45'-6"
16'-8" 30'-0" 30'-0" 30'-0" 32'-6" 32'-6" 32'-6" 32'-6" 32'-6" 32'-6" 30'-0" 331'-8"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
30'-0"
12'-4" 7'-10"
230'-2"
44'-0" YOGA TERRACE TURF FUNCTIONAL ZONE SEATING TRELLIS/CANOPY ABOVE FITNESS AREA EQUIP/ COPY MNGR OFFICE ASST MNGR TESTING JAN/ STOR STOR COPY STAIR 5 BI-FOLD OPERABLE DOOR STAIR 4 STAIR 3 YOGA FOYER IDF/ ELEC B1 B7 PSD B2 Building 2 Floor Plans - Level 3 A8.2 1 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" Building 2: Floor Plan Level 3 DN S 3 4 5 6 7 8 1010 1111 1212 MQ XE X2 X3 X4 X5 X6 X7 X8 X9 X10 U 9 N NORMAL POWER ELEC. RM ELEVATOR MECH MECHANICAL EQUIPMENT AREA ROOF AREA EXHAUST STACK EMERGENCY POWER MECHANICAL PENTHOUSE 242'-3" 32'-3" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 32'-6" 32'-6" 32'-6" 32'-6" 32'-6" 32'-6" 30'-0" 285'-0" 45'-6" 30'-0" 48'-6" 38'-0" STAIR 5
162'-0" LINE OF TERRACE BELOW WATER HEATER B1 B7 PSD B2 Building 2 Floor Plans - Roof Plan A8.3 1 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" Building 2: Roof Plan Q S U TEXTURED ACCENT TERRA COTTA BAND RIBBED METAL PANEL (RANDOM PATTERN OF 2 COLORS) HIGH PERFORMANCE VISION GLASS TYPE 1 W/ ALUM. MULLION SYSTEM RIBBED METAL PANEL TYPE 2 - BRONZE COLOR METAL PANEL TYPE 2 - GRAY COLOR TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) PAINTED STEEL CANOPY WITH STANDING SEAM ROOF HIGH PERFORMANCE VISION GLASS TYPE 1 W/ ALUM. MULLION SYSTEM TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) X1.4 X1 METAL LOUVERS TYPE 2 - BRONZE COLOR RIBBED METAL PANEL TYPE 2 - BRONZE COLOR PAINTED STEEL TRELLIS HIGH PERFORMANCE SPANDREL GLASS W/ ALUM. MULLION SYSTEM PAINTED STEEL CANOPY WITH STANDING SEAM ROOF RIBBED METAL PANEL TYPE 1 - BRONZE COLOR STEEL STRUCTURE WITH RETRACTIBLE FABRIC CANOPY TEXTURED ACCENT TERRA COTTA BAND METAL PANEL TYPE 2 - GRAY COLOR PAINTED STEEL CANOPY W/ STANDING SEAM ROOF HIGH PERFORMANCE VISION GLASS TYPE 2 W/ ALUM. MULLION SYSTEM X10 X9 X8 X7 X6 X5 X4 X3 X2 1 2 3 4 5 6 7 8 9 10 11 12 TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) METAL PANEL SUNSHADES TYPE 2 - BRONZE COLOR HIGH PERFORMANCE SPANDREL GLASS W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE VISION GLASS TYPE 1 W/ ALUM. MULLION SYSTEM RIBBED METAL PANEL TYPE 2 - BRONZE COLOR PERFORATED METAL PANEL (2 COLORS) TEXTURED ACCENT TERRA COTTA BAND RIBBED METAL PANEL (RANDOM PATTERN OF 2 COLORS) METAL PANEL TYPE 2 - GRAY COLOR METAL PANEL CANOPY TYPE 2 - BRONZE COLOR RIBBED METAL PANEL TYPE 1 - BRONZE COLOR U S Q M PERFORATED METAL PANEL (2 COLORS) TEXTURED ACCENT TERRA COTTA BAND RIBBED METAL PANEL TYPE 1 - BRONZE COLOR HIGH PERFORMANCE SPANDREL GLASS W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE VISION GLASS TYPE 1 W/ ALUM. MULLION SYSTEM TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) RIBBED METAL PANEL TYPE 2 - BRONZE COLOR RIBBED METAL PANEL (RANDOM PATTERN OF 2 COLORS) SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" North Elevation 1 1" = 20'-0" West Elevation 3 1" = 20'-0" South Elevation 2 1" = 20'-0" East Elevation 4 4 2 3 1 Building 2 Amenities Exterior Elevations A9 FE ACDEF Y1 Y2 Y2.9 Y4 2 3 4 5 6 7 8 9 CB CD CE CF B 1 CB.7 CA B.3 E.7 C.2 C.8 C.7 CA.1 1.1 Y3 35'-4" 30'-4" 6" 24'-2" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 12'-0" 30'-0" 30'-0" 9'-0"
6'-0"
21'-0" 9'-0" 30'-0" 12'-0" 2'-9"
2'-0"
31'-0" 19'-9 1/2"
30'-0"
15'-0"
30'-8"
41'-10"
2'-0" LOBBY FIRE COMMAND VEST. STAIR 2 ELEC WOMEN MEN IDF STAIR 1 VEST ELEC MPOE IDF VEST STAIR 3 ELEC GEN SWITCH BOARD RM LOADING DOCK ELEV. CONTROL WATER PUMP RM PG&E ELEC TRANSFORMER RM AHU TRASH ENCLOSURE GENERATOR FIRE WATER PUMP TENANT SPACE 90'-4" 198'-0"
139'-3 1/2"
161'-9" SERVICE ELEV. ENTRY CANOPY ABOVE JAN FIRE TANK BELOW B1 B2 B7 PSD Building 7 Floor Plans - Level 1 A10 1 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" Building 7: Floor Plan Level 1 FE
A
C
D
E
F
Y1
Y2
Y2.9
Y4
2 3 4 5 6 7 8 9
CB
CD
CE
CF
B
1 CB.7
CA
B.3
E.7
C.2
C.8
C.7
CA.1
1.1 Y3
30'-4"
24'-2" 6"
33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0"
12'-0" 30'-0" 30'-0" 9'-0"
6'-0"
21'-0" 9'-0" 30'-0" 12'-0" 2'-9"
2'-0"
31'-0"
19'-9 1/2"
30'-0"
15'-0"
30'-8"
41'-10"
2'-0"
90'-4"
198'-0"
139'-3 1/2"
161'-9"
VEST.
ELEC
WOMEN
MEN
IDF
STAIR 1 VEST
ELEC
IDF VEST
TENANT SPACE SERVICE
ELEV.
BALCONY
BALCONY
STAIR 3
35'-4"
JAN
SERVICE
ELEV. VEST.
STAIR 2
A
C
D
E
F
Y1
Y2
Y2.9
Y4
2 3 4 5 6 7 8 9
CB
CD
CE
CF
B
1 CB.7
CA
B.3
E.7
C.2
C.8
C.7
CA.1
1.1 Y3
35'-4"
30'-4"
6" 24'-2"
33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0"
12'-0" 30'-0" 30'-0" 9'-0"
6'-0"
21'-0" 9'-0" 30'-0" 12'-0" 2'-9"
2'-0"
31'-0"
19'-9 1/2"
30'-0"
15'-0"
30'-8"
41'-10"
2'-0"
90'-4"
198'-0"
139'-3 1/2"
161'-9"
VEST.
ELEC
WOMEN
MEN IDF
STAIR 1 VEST
ELEC
IDF VEST
TENANT SPACE
ENTRY CANOPY BELOW
STAIR 3
JAN
SERVICE
ELEV.
SERVICE
ELEV. VEST.
STAIR 2
B1
B2 PSD
B7
Building 7 Floor Plans - Levels 2 and 3 A10.1
2 1
SOUTHLINE
C 2022
Project Number: 10154.001
Phase 1 Precise Plan
Submittal #1 11.01.2019
Re-Submittal #2 05.18.2020
Re-Submittal #3 02.08.2021
Re-Submittal #4 03.01.2022
Re-Submittal #5 05.06.2022
1" = 20'-0"
Building 7: Floor Plan Level 3
1" = 20'-0"
Building 7: Floor Plan Level 2
A
C
D
E
F
Y1
Y2
Y2.9
Y4
2 3 4 5 6 7 8 9
CB
CD
CE
CF
B
1 CB.7
CA
B.3
E.7
C.2
C.8
C.7
CA.1
1.1 Y3
30'-4"
6" 24'-2"
33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0"
12'-0" 30'-0" 30'-0" 9'-0"
6'-0"
21'-0" 9'-0" 30'-0" 12'-0" 2'-9"
2'-0" 31'-0"
19'-9 1/2"
30'-0"
15'-0"
30'-8"
41'-10"
2'-0"
90'-4"
198'-0"
139'-3 1/2"
161'-9"
VEST.
ELEC
WOMEN
MEN
IDF
STAIR 1 VEST
ELEC
IDF VEST
TENANT SPACE
35'-4"
STAIR 3
JAN
SERVICE
ELEV.
SERVICE
ELEV. VEST.
STAIR 2
A
C
D
E
F
Y1
Y2
Y2.9
Y4
2 3 4 5 6 7 8 9
CB
CD
CE
CF
B
1 CB.7
CA
B.3
E.7
C.2
C.8
C.7
CA.1
1.1 Y3
30'-4"
6" 24'-2"
33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0"
12'-0" 30'-0" 30'-0" 9'-0"
6'-0"
21'-0" 9'-0" 30'-0" 12'-0" 2'-9"
2'-0" 31'-0"
19'-9 1/2"
30'-0"
15'-0"
30'-8"
41'-10"
2'-0"
90'-4"
198'-0"
139'-3 1/2"
161'-9"
VEST.
ELEC
WOMEN
MEN IDF
STAIR 1 VEST
ELEC
IDF VEST
TENANT SPACE
ELEV.
35'-4"
STAIR 3
SERVICE
ELEV.
SERVICE
ELEV. VEST.
STAIR 2
B1
B2
B7
PSD
Building 7 Floor Plans - Levels 4 and 5 A10.2
2 1
SOUTHLINE
C 2022
Project Number: 10154.001
Phase 1 Precise Plan
Submittal #1 11.01.2019
Re-Submittal #2 05.18.2020
Re-Submittal #3 02.08.2021
Re-Submittal #4 03.01.2022
Re-Submittal #5 05.06.2022
1" = 20'-0"
Building 7: Floor Plan Level 5
1" = 20'-0"
Building 7: Floor Plan Level 4
ACDEF Y1 Y2 Y2.9 Y4 2 3 4 5 6 7 8 9 CB CD CE CF B 1 CB.7 CA B.3 E.7 C.2 C.8 C.7 CA.1 1.1 Y3 30'-4" 6" 24'-2" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 12'-0" 30'-0" 30'-0" 9'-0"
6'-0"
21'-0" 9'-0" 30'-0" 12'-0" 2'-9"
2'-0" 31'-0" 19'-9 1/2"
30'-0"
15'-0"
30'-8"
41'-10"
2'-0"
90'-4"
198'-0"
139'-3 1/2"
161'-9" VEST. ELEC WOMEN MEN IDF STAIR 1 VEST ELECIDF VEST TENANT SPACE 35'-4" STAIR 3 SERVICE ELEV. SERVICE ELEV. VEST. STAIR 2 ACDEF Y1 Y2 Y2.9 Y4 2 3 4 5 6 7 8 9 CB CD CE CF B 1 CB.7 CA B.3 E.7 C.2 C.8 C.7 CA.1 1.1 Y3 30'-4" 6" 24'-2" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 33'-0" 12'-0" 30'-0" 30'-0" 9'-0"
6'-0"
21'-0" 9'-0" 30'-0" 12'-0" 2'-9"
2'-0" 31'-0" 19'-9 1/2"
30'-0"
15'-0"
30'-8"
41'-10"
2'-0"
90'-4"
198'-0"
139'-3 1/2"
161'-9"
35'-4" EXHAUST STACKS - 4' DIAMETER, 3'-8" ABOVE MECH. SCREEN MECHANICAL PENTHOUSE MECHANICAL EQUIPMENT AREA B1 B2 B7 PSD Building 7 Floor Plans - Level 6 and Roof Level A10.3 1 2 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" Building 7: Roof Plan 1" = 20'-0" Building 7: Floor Plan Level 6 SPANDREL GLASS W/ ALUM. MULLION SYSTEM CA.1 CB CB.7 CD CE CF METAL PANEL SUNSHADES TYPE 2 - BRONZE COLOR CA HIGH PERFORMANCE VISION GLASS TYPE 1 W/ ALUM. MULLION SYSTEM TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) METAL LOUVERS TYPE 1 - BRONZE COLOR TEXTURED ACCENT TERRA COTTA BAND METAL PANEL CANOPY BRONZE COLOR METAL LOUVERS TYPE 2 - BRONZE COLOR SPANDREL GLASS W/ ALUM. MULLION SYSTEM 9 METAL PANEL BRONZE COLOR VERTICAL METAL PANEL TRIM BRONZE COLOR METAL PANEL CANOPY BRONZE COLOR TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) TEXTURED ACCENT TERRA COTTA BAND METAL LOUVERS TYPE 1 - BRONZE COLOR METAL SUNSHADES TYPE 1 - BRONZE COLOR RIBBED METAL PANEL TYPE 1 - BRONZE COLOR RIBBED METAL PANEL TYPE 2 - BRONZE COLOR HIGH PERFORMANCE VISION GLASS TYPE 1 W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE SPANDREL GLASS W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE VISION GLASS TYPE 2 W/ ALUM. MULLION SYSTEM FLAT BAR RAILING AT BALCONY 8 7 6 5 4 3 Y4 Y3 Y2.9 Y2 Y1 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" North Elevation 2 1" = 20'-0" West Elevation 1 2 1 Building 7 Exterior Elevations A11 F E.7 E D C.8 C.2 C B.3 B A HIGH PERFORMANCE VISION GLASS TYPE 1 W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE SPANDREL GLASS W/ ALUM. MULLION SYSTEM RIBBED METAL PANEL TYPE 1 - BRONZE COLOR TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) TEXTURED ACCENT TERRA COTTA BAND METAL LOUVERS TYPE 1 - BRONZE COLOR RIBBED METAL PANEL TYPE 2 - BRONZE COLOR METAL PANEL SUNSHADES TYPE 2 - BRONZE COLOR EXHAUST STACKS C.7 METAL PANEL SUNSHADES TYPE 2 - BRONZE COLORSPANDREL GLASS W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE VISION GLASS TYPE 1 W/ ALUM. MULLION SYSTEM HIGH PERFORMANCE SPANDREL GLASS W/ ALUM. MULLION SYSTEM 6 7 8 9 RIBBED METAL PANEL TYPE 1 - BRONZE COLOR RIBBED METAL PANEL TYPE 2 - BRONZE COLOR METAL PANEL BRONZE COLOR TERRA COTTA TILE (PATTERN OF 3 TEXTURES) METAL LOUVERS TYPE 1 - BRONZE COLOR VERTICAL METAL PANEL TRIM BRONZE COLOR METAL ROLL-UP DOOR BRONZE COLOR TEXTURED ACCENT TERRA COTTA BAND EXHAUST STACKS 1 1.1 2 3 4 5 SCREEN FOR COOLING TOWER SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" South Elevation 2 1" = 20'-0" East Elevation 1 Building 7 Exterior Elevations A11.1 2 1 PS-D B1 B2 ELEC B7 STAIR 1 ELEV. STAIR 2 BIKE ENCLOSURE MPOE FIRE PUMP RM. STORAGE TRANSFORMER 63'-0" 63'-0" 67'-0"
193'-0"
18'-0" 29'-0" 18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0" 29'-0" 18'-0" 328'-0"
27'-0" 45'-0"18'-0" ELEC. RM. UP SLOPE 5.5% 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 162'-0" 2 STORY VOLUME LINE OF LEVEL 2 ABOVE 25'-0" 27'-0" 25'-0"
25'-0"
25'-0" B1 TRASH ENCLOSURE GA G1 GBGCGD G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G15 G16 G17 X2 X3 G18 XJ XI XH XG XF XE XD XC XB XA G14 X1 FIRE COMMAND RM. ELEV. CTRL. RM. SCREEN WALL 18'-0" 29'-0" 18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0" 29'-0" 18'-0" 328'-0" 18'-0" 29'-0" 18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0" 29'-0" 18'-0" 328'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 162'-0"ELEC STAIR 1 ELEV. STAIR 2 UP SLOPE 5.5% SLOPE 5.51% DOWN OPEN TO BELOW 25'-0" 25'-0"
25'-0"
25'-0"
25'-0"
15'-0" ONE WAY
63'-0" 63'-0" 67'-0"
193'-0" LINE OF LEVEL 2 ABOVE 27'-0" 45'-0"18'-0" GA G1 GBGCGD G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G15 G16 G17 X2 X3 G18 XJ XI XH XG XF XE XD XC XB XA G14 X1 LOCATION FOR GRAPHICS (LEVELS 2-6) LOCATION FOR GRAPHICS (LEVELS 2-6) 18'-0" 29'-0" 18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0" 29'-0" 18'-0" 328'-0"
18'-0" 29'-0" 18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0" 29'-0" 18'-0" 328'-0"
18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 162'-0" STAIR 1 ELEV. STAIR 2 UP SLOPE 5.5% SLOPE 5.5% DOWN 63'-0" 63'-0" 67'-0"
193'-0" 25'-0"
25'-0"
25'-0"
25'-0"
25'-0"
27'-0" 45'-0"18'-0" GA G1 GBGCGD G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G15 G16 G17 X2 X3 G18 XJ XI XH XG XF XE XD XC XB XA G14 X1 ELEC LINE OF LEVEL BELOW LOCATION FOR GRAPHICS (LEVELS 2-6) LOCATION FOR GRAPHICS (LEVELS 2-6) 18'-0" 29'-0" 18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0" 29'-0" 18'-0" 328'-0" 18'-0" 29'-0" 18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0" 29'-0" 18'-0" 328'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 162'-0" STAIR 1 ELEV. STAIR 2 UP SLOPE 5.5% SLOPE 5.5% DOWN 63'-0" 63'-0" 67'-0"
193'-0" 25'-0"
25'-0"
25'-0"
25'-0"
25'-0"
27'-0" 45'-0"18'-0" GA G1 GBGCGD G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G15 G16 G17 X2 X3 G18 XJ XI XH XG XF XE XD XC XB XA G14 X1 ELEC LOCATION FOR GRAPHICS (LEVELS 2-6) LOCATION FOR GRAPHICS (LEVELS 2-6) SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 3 Parking Structure D Floor Plans - Levels 1 to 4 A12 PS-D: Surface Level 1 PS-D: Level 2 2 PS-D: Level 3 PS-D: Level 4 4 PS-D B1 B2 B7 18'-0" 29'-0" 18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0" 29'-0" 18'-0" 328'-0"
18'-0" 29'-0" 18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0" 29'-0" 18'-0" 328'-0"
18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 162'-0" STAIR 1 ELEV. STAIR 2 UP SLOPE 5.5% SLOPE 5.5% DOWN 63'-0" 63'-0" 67'-0"
193'-0" 25'-0"
25'-0"
25'-0"
25'-0"
25'-0"
27'-0" 45'-0"18'-0" GA G1 GBGCGD G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G15 G16 G17 X2 X3 G18 XJ XI XH XG XF XE XD XC XB XA G14 X1 ELEC LOCATION FOR GRAPHICS (LEVELS 2-6) LOCATION FOR GRAPHICS (LEVELS 2-6) 18'-0" 29'-0" 18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0"18'-0" 29'-0" 18'-0" 328'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 18'-0" 162'-0" STAIR 2 63'-0" 63'-0" 67'-0"
193'-0"
25'-0"
25'-0"
25'-0" 26'-0" 25'-0"
27'-0" 45'-0"18'-0" GA G1 GBGCGD G2 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G15 G16 G17 X2 X3 G18 XJ XI XH XG XF XE XD XC XB XA G14 X1 SLOPE 5.5% DOWN LOCATION FOR GRAPHICS (LEVELS 2-6) LOCATION FOR GRAPHICS (LEVELS 2-6) STAIR 1 ELEV. PS-D: Level 5 1 SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 Parking Structure D Floor Plans - Levels 5 and 6 A12.1 PS-D: Level 6 2 G18 G17 G16 G15 G14 G13 G12 G11 G10 G9 G8 G7 G6 G5 G4 G3 G2 VISION AND SPANDREL GLASS IN CURTAIN WALL SYSTEM METAL ACCENT FINS TERRA COTTA TILE, (RANDOM PATTERN OF 3 TEXTURES) ACCENT TEXTURED PAINTED CONCRETE TO MATCH TERRA COTTA PANELS AT OFFICE BUILDINGS GARAGE ENTRANCE/ EXIT GARAGE ENTRANCE/ EXIT LIGHT GRAY TEXTURED PAINTED CONCRETE DARK GRAY TEXTURED PAINTED CONCRETE GREEN SCREEN GRAY TEXTURED PAINTED CONCRETE G1 TERRA COTTA TILE, (RANDOM PATTERN OF 3 TEXTURES) XJ XI XH XG XF XE XD XC XB XA ACCENT TEXTURED PAINTED CONCRETE TO MATCH TERRA COTTA PANELS AT OFFICE BUILDINGS PERFORATED METAL PANELS (COLOR TO MATCH PERFORATED PANELS AT AMENITIES BUILDING) CABLE RAIL RIBBED PERFORATED METAL PANEL (RANDOM PATTERN OF 2 COLORS) LIGHT GRAY TEXTURED PAINTED CONCRETE GREEN SCREEN GA GB GC GD TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) ACCENT TEXTURED PAINTED CONCRETE TO MATCH TERRA COTTA PANELS AT OFFICE BUILDINGS LIGHT GRAY TEXTURED PAINTED CONCRETE DARK GRAY TEXTURED PAINTED CONCRETE RIBBED PERFORATED METAL PANEL (RANDOM PATTERN OF 2 COLORS) CABLE RAIL PERFORATED METAL PANELS (COLOR TO MATCH PERFORATED PANELS AT AMENITIES BUILDING) CMU WALL (RANDOM PATTERN OF 3 TEXTURES) 2 STORY VOLUME FOR BUILDING 1 LOADING TRUCK TURNING GRAY TEXTURED PAINTED CONCRETE G1 G3 G4 G5 G6 G7 G8 G9 G10 G11 G12 G13 G14 G15 GRAY TEXTURED PAINTED CONCRETE ACCENT TEXTURED PAINTED CONCRETE TO MATCH TERRA COTTA PANELS AT OFFICE BUILDINGS CABLE RAIL RIBBED PERFORATED METAL PANEL (RANDOM PATTERN OF 2 COLORS) LIGHT GRAY TEXTURED PAINTED CONCRETE PERFORATED METAL PANELS (COLOR TO MATCH PERFORATED PANELS AT AMENITIES BUILDING) CMU WALL GREEN SCREEN (RANDOM PATTERN OF 3 TEXTURES) LOCATION FOR GRAPHICS DARK GRAY TEXTURED PAINTED CONCRETE G2 SERVICE SCREEN WALL SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 1" = 20'-0" North Elevation 1 1" = 20'-0" East Elevation 3 1 Parking Structure D Exterior Elevations A13 4 1" = 20'-0" South Elevation 2 1" = 20'-0" West Elevation 4 3 2 TYP. TYP. TYP. TYP. AA 1ST FLOOR 2ND FLOOR 3RD FLOOR 4TH FLOOR 5TH FLOOR 6TH FLOOR ROOF METAL TRIM AROUND WINDOW METAL PANEL SUNSHADES TYPE 2 - BRONZE COLOR 13' CEILING 11' CEILING, TYP. TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) BB LOBBY METAL PANEL CANOPY BRONZE COLOR 1ST FLOOR 3RD FLOOR 4TH FLOOR 5TH FLOOR 6TH FLOOR ROOF 11' CEILING, TYP. CC TYP. METAL PANEL HORIZONTAL TRIM TYPE 1 - BRONZE METAL METAL PANEL SUNSHADES TYPE 2 - BRONZE METALTYP. TYP. TYP. 1ST FLOOR 2ND FLOOR 3RD FLOOR 4TH FLOOR 5TH FLOOR 6TH FLOOR ROOF13' CEILING 11' CEILING, TYP.TYP. TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) RIBBED METAL PANEL TYPE 2 - BRONZE COLOR SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 Typical wall section A-A 1 Typical wall section B-B 2 Typical wall section C-C 3 Typical Wall Sections Buildings 1 and 7 A14A A B C B C B1 B7 AABB C C AA 2ND LEVEL 3RD LEVEL ROOF 1ST LEVEL METAL PANEL TYPE 2 - GRAY COLOR STEEL STRUCTURE W/ RETRACTIBLE FABRI CANOPY PAINTED STEEL CANOPY W/ STANDING SEAM ROOF 2ND LEVEL 3RD LEVEL ROOF 1ST LEVEL BB PAINTED STEEL CANOPY W/ STANDING SEAM ROOF METAL LOUVERS TYPE 2 - BRONZE COLOR TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) CC 2ND LEVEL 3RD LEVEL ROOF 1ST LEVEL TERRA COTTA TILE (RANDOM PATTERN OF 3 TEXTURES) RIBBED METAL PANEL (RANDOM PATTERN OF 2 COLORS) RIBBED METAL PANEL TYPE 1 - BRONZE COLOR RIBBED METAL PANEL TYPE 2 - BRONZE COLOR PERFORATED METAL PANEL (2 COLORS) SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 Typical wall section A-A 1 Typical wall section B-B 2 Typical wall section C-C 3 Typical Wall Sections Building 2 A14.1 A A CC BB
METAL PARAPET CAP CMU (RANDOM PATTERN
OF 3 TEXTURES) PS-D B1 B2 B7 METAL PARAPET CAP GREENSCREEN PANEL CMU (RANDOM PATTERN OF 3 TEXTURES) 2x METAL TUBE (BRONZE COLOR TO MATCH BLDG) BUILDING 1 FIRE PUMP GENERATOR ENCLOSURE BUILDING 1 METAL PARAPET CAP CMU (RANDOM PATTERN OF 3 TEXTURES) METAL LOUVERSCMU (RANDOM PATTERN OF 3 TEXTURES) METAL PARAPET CAP GREENSCREEN PANEL 2x METAL TUBE (BRONZE COLOR TO MATCH BLDG) METAL PARAPET CAP CMU (RANDOM PATTERN OF 3 TEXTURES) GREENSCREEN PANEL 2x METAL TUBE (BRONZE COLOR TO MATCH BLDG) BUILDING 1 TRASH ENCLOSURE PARKING STRUCTURE D SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 Building 1: Service Yard Enlarged Plan 1 Building 1 Service Yard Plan and Elevations A15 3 6 Building 1: Service Yard East Elevation 4 Building 1: Service Yard West Elevation 3 Building 1: Service Yard North Elevation 5 5 4 Building 1: Service Yard South Elevation 6 Building 1: Service Yard Section AA 7 A A Building 1: Trash Enclosure Enlarged Plan 2 PS-D B1 B2 B7 CMU (RANDOM PATTERN OF 3 TEXTURES) METAL PARAPET CAP 2x METAL TUBE METAL PARAPET CAP (BRONZE COLOR TO MATCH BLDG) GREENSCREEN PANEL LOUVERED GATE CMU (RANDOM PATTERN OF 3 TEXTURES) TRASH ENCLOSURE GENERATOR ENCLOSURE BUILDING 7 FIRE PUMP METAL PARAPET CAP METAL LOUVERS CMU (RANDOM PATTERN OF 3 TEXTURES) METAL PARAPET CAP GREENSCREEN PANEL CMU (RANDOM PATTERN OF 3 TEXTURES) BUILDING 7 CMU (RANDOM PATTERN OF GREENSCREEN PANEL 3 TEXTURES) 2x METAL TUBE (BRONZE COLOR TO MATCH BLDG) METAL PARAPET CAP SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 Building 7: Service Yard Enlarged Plan 1 Building 7 Service Yard Plan and Elevations A16 Building 7: Service Yard East Elevation 3 Building 7: Service Yard North Elevation 6 5 3 4 6A Building 7: Service Yard West Elevation 4 Building 7: Section AA 2A Building 7: Service Yard South Elevation 5 BALED BALED CARDBOARD CARDBOARD 2 CY COMPOST BIN LOOSE RECYCLE 4 CY BIN RECYCLE PAPER 4 CY BIN WASTE 4 CY BIN WASTE COMPACTOR COMPOST COMPACTOR CARDBOARD BALER RECYCLE PAPER COMPACTOR PS-D B1 B2 B7 BALED CARDBOARD RECYCLE 3 CY BIN RECYCLE COMPACTOR COMPOST 2 CY BIN CARDBOARD BALER WASTE 4 CY BIN RECYCLE PAPER 4 CY BIN RECYCLE COMPACTOR WASTE COMPACTOR BALED CARDBOARD RECYCLE PAPER 4 CY BIN WASTE 4 CY BIN 1/2 CY CART 1/2 CY CART CARDBOARD BALER COMPOST 3 CY BINRECYCLE 3 CY BIN RECYCLE COMPACTOR BALED CARDBOARD BALED CARDBOARD SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 Building 1: Trash Enclosure Plan 1 Enlarged Trash Enclosure Plans A17 Building 2: Trash Enclosure Plan 2 Building 7: Trash Enclosure Plan 3 3 1 2
MATCH LINE SEE SHEET C2.2
MATCH LINE SEE SHEET C2.1
MATCH LINE SEE SHEET C2.3
MATCH LINE SEE SHEET C2.2
MATCH LINE
SEE SHEET C4.2
MATCH LINE SEE SHEET C4.1
MATCH LINE
SEE SHEET C5.2
MATCH LINE SEE SHEET C5.1
TYPE 1 BIORETENTION AREA TYPE 2 BIORETENTION AREA
DRAINAGE AREA
DESIGNATION
PROPOSED IMPERVIOUS
DRAINAGE AREA
(SF)
TREATMENT
METHOD
PONDING
DEPTH
(INCHES)
REQUIRED
TREATMENT AREA
(SF)
PROVIDED
TREATMENT AREA
(SF)
EXCESS TREATMENT
AREA
(SF)
TREATMENT AREA
DESIGNATION
R-1 55,126 Bioretention Area 6 1,654 1,877 223 T2
P-1 8,352 Bioretention Area 6 251 687 436 T1
P-2 3,355 Bioretention Area 6 101 436 336 T1
R-2 27,020 Bioretention Area 6 811 918 107 T8
P-3 11,722 Bioretention Area 6 352 382 31 T3
R-3 33,775 Bioretention Area 6 1,013 1,071 58 T5
R-4 10,544 Bioretention Area 6 316 937 621 T10
P-4 4,858 Self-Retaining 6 2,429 - - -
R-5 15,831 Bioretention Area 6 475 621 146 T10
P-5 1,884 Self-Retaining 6 942 - - -
R-6 21,108 Bioretention Area 6 633 642 8 T11
P-6 1,813 Self-Retaining 6 906 - - -
R-7 13,576 Bioretention Area 6 407 438 31 T12
P-7 4,102 Self-Retaining N/A 2,051 - - -
R-8 6,788 Bioretention Area 6 204 239 35 T14
P-8 5,669 Self-Retaining N/A 2,835 - - -
R-9 40,730 Bioretention Area 6 1,222 1,803 581 T13
P-9 11,757 Bioretention Area 6 353 1,290 937 T10
P-10 10,956 Bioretention Area 6 329 330 1 T7
P-11 4,848 Self-Retaining N/A 2,424 - - -
P-12 346 Self-Retaining N/A 173 - - -
P-13 1,025 Self-Retaining N/A 513 - - -
R-14 5,531 Bioretention Area 6 166 262 96 T4
P-14 20,282 Bioretention Area 6 608 1,250 642 T11
P-15 8,026 Bioretention Area 6 241 679 438 T12
RW-1 29,691 Bioretention Area 6 1,188 1,347 159 T16
RW-2 115,656 Bioretention Area 6 4,626 4,668 42 T11
RW-3 21,223 In-lieu by RW-3 N/A 849 1,347 498 T16
STORMWATER TREATMENT TABLE
L L DN L Bldg 1
318,380 sf 6 stories +26 FF Bldg 7 296,620 sf 6 stories +24 FF Bldg 2 - Amenities 69,710 sf 1 story above 2 level parking +28 FF MOBILITY HUB RIDE SHARE PSD S+5 levels +23.5 FF SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 KEY NOTES: SOUTHLINE PLAZA LOBBY PLAZA GRAND STAIRS GENERAL NOTES: FIRE LANE SERVICE AREA COMMUNITY PICNIC AREA COMMUNITY KIDS PLAY AREA CONCEPTUAL LANDSCAPE PLAN L1 PROPOSED TREE LIST REFER TO GRAPHIC PACKAGE FOR ADDITIONAL IMAGERY AND ALL STREET SECTIONS. SHEET NOTES: DOLLAR AVENUE N. LINDEN AVENUE TANFORAN AVENUE MAPLE AVENUE STORMWATER DEMONSTRATION GARDEN BIORETENTION AREA BIORETENTION AREA NEW ROAD TANFORAN AVENUE GAMING AREA W/ SHADE SAIL STRUCTURE N. LINDEN AVENUE NEW ROAD HUNTINGTON AVE.
HUNTINGTON AVE.
UP SOUTHLINE C 2022 Project Number: 10154.001 Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 SOUTHLINE PLAZA AND PROJECT FRONTAGE ENLARGEMENT PLAN L2.2 KEY NOTES: GRAND STAIRS W/ BANDING EXTEND INTO LANDSCAPE SOUTHLINE PLAZA PUBLIC SIDEWALK BIKE LANE PUBLIC CROSSWALK OUTDOOR DINING, TYP. LANDSCAPE STRIPE NEW ROAD CONCRETE SEAT WALL W/ WOOD BENCH SHRUB & GROUNDCOVER SHEET NOTES: BLDG 2 - Amenities SERVICE AREA BIORETENTION AREA FUTURE MONUMENT SIGNAGE W/ ENHANCED LANDSCAPE PALETTE TREE GRATE, TYP. REFER TO GRAPHIC PACKAGE FOR ADDITIONAL IMAGERY AND ALL STREET SECTIONS. BIORETENTION AREA TANFORAN AVE HUNTINGTON AVE. MAPLE AVE.
ACER BUERGERIANUM
SUMMER
MAGNOLIA SOULANGEANA
ACCENT - SUMMER
MAGNOLIA SOULANGEANA
ACCENT - SPRING
CERCIS OCCIDENTALIS
ACCENT
ARBUTUS ‘MARINA’
EVERGREEN | ACCENT
GINKGO BILOBA ‘PRINCETON SENTRY’
SUMMER
GINKGO BILOBA ‘PRINCETON SENTRY’
FALL
LOPHOSTEMON CONFERTUS
STREET TREE | EVERGREEN | SCREEN
PINUS CANARIENSIS
EVERGREEN | SCREEN
ULMUS PARVIFOLIA
CANOPY | SEMI-EVERGREEN
POPULUS FREMONTII
CANOPY
EUCALYPTUS CITRIODORA
SCREEN
PHORMIUM ‘JUBILEE’ RHAMNUS CALIFORNICA RHAMNUS ALATERNUS ACHILLEA MILLEFOLIUM CEANOTHUS G. H. ‘DIAMOND HEIGHT’ CEANOTHUS G. H. ‘YANKEE POINT’ ROSA ‘FLOWER CARPET’ COLEONEMA PULCHRUM CORREA SPECIES DIETES BICOLOR HEMEROCALLIS SPECIES PHORMIUM ‘DARK DELIGHT’ CALAMAGROSTIS A. ‘KARL FOERSTER’ CALAMAGROSTIS BRACHYTRICHA CAREX TUMULICOLA CHONDROPETALUM TECTORUM JUNCUS PATENS LEYMUS C. ‘CANYON PRINCE’
BIORETENTION PLANTING
TREE PALETTE
SHRUB AND GROUNDCOVER PALETTE
MISCANTHUS S. ‘ADAGIO’ MUHLENBERGIA CAPILLARIS PENNISETUM RUBRUM DISTICTIS BUCCINATORIA TRACHELOSPERMUM JASMINOIDES OLEA EUROPAEA ‘SWAN HILL’
EVERGREEN | ACCENT
ACER BUERGERIANUM
FALL
CONCRETE PAVING
MOVABLE TABLES & CHAIRS OPTION
BENCH
MOVABLE TABLES & CHAIRS OPTION BIKE RACKS
PICNIC TABLE
CONCRETE UNIT PAVERS
DG PAVING
PAVING PALETTE
RETAIL AND LOBBY PLAZA FURNITURE
VEGGIE GARDEN COMMUNITY GARDEN FURNITURE
CONCRETE SEAT WALL W/ WOOD BENCH CONCRETE WALL W/ STAGGERED
BOARD FORM FINISH
PRE-FAB TRANSIT HUB SHELTER
RAISED PLANTER WIRE MESH FENCE
UP FOOD SERVICE STAIR 1 102 STAIR 1 VEST. 101 241 SF FC ROOM 123 WOMEN 105 MEN 106 STAIR 3 111 DW PUMP ROOM 116 OPEN OFFICE 124 STAIR 2 108 IDF 113 IDF 104 ELEC. RM 103 STAIR 3 VEST. 110 JANITOR 107 GENERATOR ENCLOSURE 1S102 ELEV. B ELEV. A LOBBY 100 ELEV. E ELEV. C ELEV. D ELECTRICAL SUBSTATION 120 PGE 119 EMERGENCY ELECTRICAL 118 MPOE 117 FIRE WATER PUMP 1S103 STAIR 2 VEST. 109 ELEC. RM 112 ELEVATOR CONTROL ROOM 114 LOADING DOCK 115 AHU 126 LOADING DOCK 125 ELEC TRANSFORMER RM123 PG&E ELEC RM104 WATER PUMP RM 108 ELEC GEN SWITCH BOARD RM 124 ELEC. 117 MPOE 112 ELEV CTR RM. 126 IDF116 STAIR 3 VEST 114 STAIR 3 113 STAIR 1 VEST 103 STAIR 1 102 LOBBY 100 ELEC 109 MEN'S RESTROOM 140 WOMEN'S RESTROOM 135 WOMEN'S SHOWER 131 MEN'S SHOWER 141 FIRE COMMAND RM107 STAIR 2 110 ELEV A ELEV B ELEV D ELEV C GENERATOR ENCLOSURE 120 FIRE PUMP ROOM 118 OPEN OFFICE 101 STAIR 2 VEST. 111 AHU ROOM 150 TRASH ENCLOSURE 121 FIRE TANK ROOM BELOW IDF 105 FUTURE GENERATOR ENCLOSURE 706E Bldg 1 318,380 sf 6 stories +26 FF Bldg 7 296,620 sf 6 stories +24 FF Bldg 2 - Amenities 69,710 sf 1 story above 2 level parking +28 FF MOBILITY HUB RIDE SHARE PSD S+5 levels +23.5 FF TANFORAN AVE. TANFORAN AVE. DOLLAR AVE.
DOLLAR AVE. NEW ROAD NEW ROAD
N. LINDEN AVE.
N. LINDEN AVE.
S. MAPLE AVE.
HUNTINGTON AVE.
HUNTINGTON AVE.
HUNTINGTON AVE. UP FOOD SERVICE STAIR 1 102 STAIR 1 VEST. 101 241 SF FC ROOM 123 WOMEN 105 MEN 106 STAIR 3 111 DW PUMP ROOM 116 OPEN OFFICE 124 STAIR 2 108 IDF 113 IDF 104 ELEC. RM 103 STAIR 3 VEST. 110 JANITOR 107 GENERATOR ENCLOSURE 1S102 ELEV. B ELEV. A LOBBY 100 ELEV. E ELEV. C ELEV. D ELECTRICAL SUBSTATION 120 PGE 119 EMERGENCY ELECTRICAL 118 MPOE 117 FIRE WATER PUMP 1S103 STAIR 2 VEST. 109 ELEC. RM 112 ELEVATOR CONTROL ROOM 114 LOADING DOCK 115 AHU 126 LOADING DOCK 125 ELEC TRANSFORMER RM123 PG&E ELEC RM104 WATER PUMP RM 108 ELEC GEN SWITCH BOARD RM 124 ELEC. 117 MPOE 112 ELEV CTR RM. 126 IDF116 STAIR 3 VEST 114 STAIR 3 113 STAIR 1 VEST 103 STAIR 1 102 LOBBY 100 ELEC 109 MEN'S RESTROOM 140 WOMEN'S RESTROOM 135 WOMEN'S SHOWER 131 MEN'S SHOWER 141 FIRE COMMAND RM107 STAIR 2 110 ELEV A ELEV B ELEV D ELEV C GENERATOR ENCLOSURE 120 FIRE PUMP ROOM 118 OPEN OFFICE 101 STAIR 2 VEST. 111 AHU ROOM 150 TRASH ENCLOSURE 121 FIRE TANK ROOM BELOW IDF 105 FUTURE GENERATOR ENCLOSURE 706E Bldg 1 318,380 sf 6 stories +26 FF Bldg 7 296,620 sf 6 stories +24 FF Bldg 2 - Amenities 69,710 sf 1 story above 2 level parking +28 FF MOBILITY HUB RIDE SHARE PSD S+5 levels +23.5 FF TANFORAN AVE. TANFORAN AVE. DOLLAR AVE.
DOLLAR AVE. NEW ROAD NEW ROAD
N. LINDEN AVE.
N. LINDEN AVE.
S. MAPLE AVE.
HUNTINGTON AVE.
HUNTINGTON AVE.
HUNTINGTON AVE. C 2022 Project Number: 10154.001 LIGHTING SHEET TILING PLAN E1.0 E1.1/ AREA 1 E1.2/ AREA 2 E1.3/ AREA 3 SOUTHLINE Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021 Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022 UP FOOD SERVICE GENERATOR ENCLOSURE 1S102 FIRE WATER PUMP 1S103 Bldg 2 - Amenities 69,710 sf 1 story above 2 level parking +28 FFTANFORAN AVE. NEW ROAD S. MAPLE AVE. HUNTINGTON AVE. HUNTINGTON AVE. UP FOOD SERVICE GENERATOR ENCLOSURE 1S102 FIRE WATER PUMP 1S103 Bldg 2 - Amenities 69,710 sf 1 story above 2 level parking +28 FFTANFORAN AVE. NEW ROAD S. MAPLE AVE. HUNTINGTON AVE. HUNTINGTON AVE. E13 E3 E3 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E1 E4 (x3) E13 E13E13 E13 E1 E1 E8E8E8 E8 E3 E3 E1 E1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 R1 E1 E1 E3 E3 E15 E15 E15 E15 E15 E15 E15 E15 E15 E15 E15 E15 E2 E11 (x10) E11(x4)E11(x4) E11 (x16) E2 E2E2E2E2E2 E2 E2 E2 E10E10 E10 E10E10 E10 E10 E10 E10 E10 E10 E10E10 E10 E10E10 E10E10E10 E10 E10 E10 E2 E2E2 E2 E2 E2 E10 E10 E10 E10 E10 E10 E10 E10 E10E10E10E10 E9 E9 E10 E10 E2 E2E2 E2E2E2 E2 E2 E2 E2 E2 E2 E2 E2 E9 E9 E9 E9 E13 E14E14 E14E14 E3 E8E8E8E8 C 2022 Project Number: 10154.001 SITE LIGHTING PLAN AREA 1 E1.1 SEE SHEET E1.2 SOUTHLINE Phase 1 Precise Plan Submittal #1 11.01.2019 Re-Submittal #2 05.18.2020 Re-Submittal #3 02.08.2021 Re-Submittal #4 03.01.2022 Re-Submittal #5 05.06.2022