Pre-Qualification CIP Rebate Application Submitted By A. Meyer; Reviewed By T. Myers; Requested Rebate Amount: $111,076.75
ATTACHMENT B
APPROVED
By Tammie Myers at 2:06 pm, 8/1/23
ATTACHMENT B
$111,076.75
26,225,720 Annual 262,257,200 Lifetime $1.60 $111,076.75
ATTACHMENT B
ATTACHMENT B
ATTACHMENT B
26,225,720 Annual 1 $111,076.75 90 days/signed contract
ATTACHMENT B
ATTACHMENT B
ATTACHMENT B
Stockton Fire Dept. Projected Training Water Flow Report Average
Flow
GPM
Time
(Minutes) Gallons per Evolution
Reps Per
year Per
Engine
Total Gallons Per Year Per
One Engine Company
1 Standard Fire attack 1 3/4" 185 5 925 108 99,900
2 Defensive Fire attack 2 1/2" with Fog Nozzle 250 10 2,500 6 15,000 3 Offensive Fire attack 2 1/2" with Smooth Bore 266 10 2,660 12 31,920 4 Lead Line Hose Pack 1 3/4" (Above Ground or Extending) 185 5 925 36 33,300 5 High Rise Pack Hose Evolutions 2.5" Hose 266 5 1,330 12 15,960 6 Standard Fire Attack 1 1/2" Hose 160 5 800 108 86,400 7 Deck Gun Drill (Multiple Tip Sizes) 1,000 5 5,000 6 30,000 8 Ground Monitor Drill 2" Tip 1,000 5 5,000 6 30,000
9 Multiple Hose Line Drill 435 10 4,350 6 26,100
10 Wildland progressive hoselay extension 85 15 1,275 3 3,825 11 Aerial Master Stream Drill 1,000 5 5,000 3 15,000
12 Total Flow Per Type 1 Engine & Quint 24,765 387,405
13 Total Flow x 13 Engine Companies 5,036,265
Average
Flow
GPM
Time
(Minutes) Gallons per Evolution
Reps
Per
Year
Total
Gallons
per Year
25 Residential structure fire - Offensive mode 650 10 6,500 6 39,000 26 Residential structure fire - Defensive mode 1,000 5 5,000 6 30,000 27 Residential structure fire - High Rise 300 10 3,000 6 18,000 30 Total Flows by Type I & Quints During Battalion Level Training 14,500 87,000 Average
Flow
GPM
Time
(Minutes) Gallons per Evolution
Reps Per
year
(Total)
Total
Gallons
per Year
33 Supply engine 1000 gpm dual intake 1,000 15 15,000 1 15,000 34 Pumping a Truck hose tower elevated master stream 1,000 5 5,000 1 5,000 37 Supply engine 1000 gpm dual intake for master stream 1,000 10 10,000 1 10,000 38 Mulitple Hose Line Drill 451 10 4,510 4 18,040
39 Max water flow from tank 1,200 5 6,000 1 6,000
40 Large Water Flow Drill 1,050 6 6,300 4 25,200
41 High Rise Structure Fire Drill 435 7 3,045 3 9,135
Deck Gun - 1 3/8" tip (Race For Water) 500 5 2,500 2 5,000 45 Relay pumping 1,000 10 10,000 1 10,000
46 Drafting w/ Multiple Lines 451 10 4,510 2 9,020
Sabotage Drills 951 10 9,510 1 9,510
47 Pumping a Truck hose tower elevated master stream 1,000 5 5,000 1 5,000 48 Total Flow During Engineer Task Book Training 81,375 126,905 49 Avg # of Engineer Candidates Per Year = 27
50 Total Engineer Task Book Training Annual Gallons = 3,426,435 51 Firefighter Recruit Academies (Avg. # Reruits = 18 ) Estimated 80 day Academy 2 4,568,580 52 Annual NFPA Pump Testing ( See Pump Testing Flow Sheet) 1,110,000 56 14,228,280
Type 1 Engine Detail
Initial Attack Standards and Other Engine Company Level Training Evolution Name
Combined Total of Annual Flows - Projected & Actual Training and Pump Testing Evolution Name
Engineer Task Book Training and Engineer Academy
Evolution Name
Battalion Level Multi - Company Training
55, 500 Gallons Flowed per Engine Test of 20 Engines
ATTACHMENT B
www.PumpPodUSA.com
June 20, 2023
Stockton Fire Department Quote #: 23-0620SFDMDU-01
Mobile DRAFTS UNIT Proposal
Dear Deputy Chief Brandon Doolan,
Thank you for your interest in our PumpPodUSA DRAFTS UNITS. We are pleased to present the following information per your request for a Mobile DRAFTS Unit (exceeds 2,100 USG). The PumpPodUSA - Direct Recirculating Apparatus Firefighting Training & Sustainability (DRAFTS) Unit apparatus is specifically designed to be the ultimate training tool to develop, maintain and test your Engineers and Firefighters. This Unit will enhance the safety, training and practice for candidates specifically while providing needed additional training opportunities to ensure that your department has the most prepared and qualified workforce today.
The DRAFTS Unit will provide and allow your department to train with Full Flow Water for your Firefighters and Engineers. When deployed out into the Battalions the Engine Companies can train WITHOUT having to call “Out of Service” thus significantly increasing the hours of training but reducing time and costs related to these exercises.
Another benefit to the DRAFTS Units is that they are self-contained and re-circulate the water required for a wide variety of training evolutions as well as a host of NFPA testing requirements and water conservation mandated compliance.
Each DRAFTS Unit will allow approximately (2,100 USG) amount of water to be pump continually, literally saving millions of gallons each year using the DRAFTS Units innovative design and construction.
General Construction Notes:
x This apparatus is constructed are custom fabricated from scatch and are reinforced in a variety of ways in order to provide long term reliability and durable service. x A custom bulkhead is constructed and welded into the container. This bulkhead is placed back from the access doors. The design also allows a safe flat deck to safely access to the nozzle mounting system. This system is customizable to suit your Training & Testing needs. variety of straight nozzle styles as well as custom additions.
x The DRAFTS UNIT is fitted with Drafting and Pressure Pipes, NH Fittings of various sizes ranging from:
1 1/2” - 6” and is available in several configurations based on your department needs. x The Diffuser Screen is mounted to a frame at an angle to divert the incoming stream downward into the reservoir. The optional hanging targets on the deflector shield are to help train nozzle operators. x All Apparatus will be coated internally with Rhino protective coatings for containment and durability. x Photographs and illustrations are included on the following pages to help illustrate the design items mentioned herein.
x 10 Year Limited Warranty
Thank you again for your interest, after your review please feel free to contact me with any questions or comments.
Sincerely,
Bill Ward
Executive Director Cell: (949)246 6999 Email: [email protected]
ATTACHMENT B
www.PumpPodUSA.com
Mobile DRAFTS Unit on 24’ Trailer Capacity: 2,100 Gallons Approx. Gross Weight (Empty): 9,700 lbs. Example: How Artwork has been applied on previous Units.
ATTACHMENT B
www.PumpPodUSA.com
DIRECT RECIRUCLING APPARATUS FIREFIGHTER
TRAINING & SUSTAINABILITY UNIT
Rear Bulkhead Wall & Interior Features:
1 G a l v a n i z e d D i f f u s e r S creen mounted to Aluminum Frame (Optional Target can be mounted) 1 S t e p w e l d e d t o I n s i d e and outside of the Bulkhead Wall 6 Welded Fire Hose & Nozzle Plates in 2.5” Ss Ni pples Capped with 2.5” NH Fittings (Aluminum) 1 200 PSI Pressure Relief Valve for FDC Plumbing (Red)
1 1 ½” Valve, the same as if they were opening of Interior Standpipe on 3 rd floor (Red) (Connected to 3 Port FDC with In-line 900 Fittings to provide for the equivalent of 150’of resistance/ friction loss)
ATTACHMENT B
www.PumpPodUSA.com
Front:
1 Safety Rail with folding Aluminum Step at front of Deck 1 6” Horizontal Draft Port (Blue) with Butter fly Valve and 6” FNH Double Swivel Fitting (Alum.) 1 6” Vertical Riser Draft Training Riser per our discussion, (for a portion of annual pump testing) 1 1 ½” Make-up Water (using an Auto-Fill with Floa t) Ball Valve with NH fitting - - Right side 1 Powder Coated Blue Parts Box
1 12 Volt Electromechanical Water Meter with Tota lizer with 12 Battery & Conditioner w/ Plugin. 1 Portable Hydrant with Stainless Steel deck plate to secure to unit to the deck during transport. 1 (3) Port FDC with 2 ½”Clap pered Snoots w/ working 3rd Story Standpipe valve with 200 PSI PRV. (Plumbed to series of 90 degree fittings Providing for 150’ of Line Restriction / friction loss.
ATTACHMENT B
www.PumpPodUSA.com
Standard Items & Features Included:
(1) Portable Wet Barrel (DB) Customized Hyd rant 6” Supply (4”, 4 ½” or 5” reducer NH Fitting) in 2 or 3 Ports Multi-layer Galvanized Expanded Steel Deflector Screen secured to Aluminum Frame. (3) Port FDC Connections – Plumbed with (3) 2 ½” Brass Clappered Snoots 5’ x 5’ Galvanized Roof Target
Swinging Nozzle Target Plate Powder coated Yellow and bolted to Diffuser Screen Non-skid flooring welded on Rear deck level with Pod Floor with aluminum heavy duty non-skid decking.
Non-skid flooring welded on Front End Deck with expanded & raised Galvanized steel.
Powder Coated Front End Safety Rail with Aluminum Folding Step Rear Stairs – Folding Aluminum with Web Strap Set for transport. Upper Handles coated with Rhino Liner.
Powder Coated Rear Deck Safety Railing -
3” Floor Drain – Nylon Ball valve with Cam Fitting and 25’ of Lay Flat Drain Hose Interior of Apparatus sprayed with watertight Rhino Liner protective coating for containment and durability.
Exterior Powder Coated Panel Siding with aluminum diamond plate trim. Artwork / Signage using a UV Wrap.
All Ball Valve Handles coated with Black Rhino Liner protective coating Custom Heavy-Duty 12” I-Beam with dual axle Trailer for PumpPod DRAFTS Unit(Painted Black with Clear Coat) Optional Items & Features
Additional - Portable Wet Barrel Customized Jones Hydrant (DB 4” x 2 1/2”, DB 4” x 2 ½” x 2 ½”) Pump Testing Manifold (5) 3” Clappered Snoots for up to 2,000 GPM Customized 3 Port Portable (DB 4” x 2 ½” x 2 ½”) Wet Barrel Jones Hydrant Fire Hose Roller (Inserted when needed into Hitch Receiver – welded on either side of Rear Portion of Trailer Warranty
10 Year Limited Warranty (See Warranty Document)
Repairs and Service of Units
Any Warranted Repairs or Non-Preventive Maintenance Service items covered by the warranty, will be performed by PumpPodUSA personnel or designated vendor. Written Notice with photographs documenting the Repair / Service Item in question shall be sent to PumpPodUSA in a timely manner from the Fire Department Fleet Services. Once PumpPodUSA reviews the issue they will decide on the course of action:
1. Local Vendor - Dispatched by PumpPodUSA… (If Item is not completed by Vendor - Refer to Option #2)
2. PumpPodUSA personnel will be dispatched to inspect and perform Repairs or Service on-site.
3. If Repair & Service Item(s) can’t be completed on-site the Unit will be transported to the factory at the manufactures time and expense. Once Repair / Service are completed it will be returned back to Fire Department at manufactures expense.
4. Fire Department Fleet representative will confirm Item in question was completed to Departments satisfaction must be signed off at time of delivery.
ATTACHMENT B
www.PumpPodUSA.com
Price Quote Da t e : J u n e 2 0 , 2 0 2 3
St
ockton Fire Department Quote #: 23-0620SFDMDU-01
Pump-Pod / DRAFTS Unit Specifications: Descriptions Unit Price:
(1) Mobile –
Approx. 2,100 Gallons
See the Following List:
Mobile Base Model
Mobile DRAFTS Unit
(see specifications above)
$96,775.00
Stenciling & Artwork Signage
Wrap
Seals, Shields & Logos -
Digital files provided by Cust.
Wrap Designed, Printed and Applied
by PumpPodUSA
Included
Diffuser Screen Layered Expanded Galvanized Secured to Aluminum Frame Included Bulkhead Inside Rear Door (1) Weld ed Step on Outside (1) Weld ed Step to Inside of Bulkhead Included (6) – 2.5” Ss Pipe Nipples
Weld
ed on Nozzle Plates
2.5” NST Fittings on each nipple Included
Front Deck 6” Butterfly Valve on Primary
Horizontal D
rafting Connection
6” FNPT to 6” FNH Dbl. Swivel Fitting
W /6” MNST x 4” FNST Swivel reducer
Included
On vertical Draft Riser –
Material Sch
ed. 80 PVC
6” FNPT to 6” MNH Fitting
Convert from Pipe to Fire Hose Threads
1” Bleeder Valve on Riser
Included
Front - Left Hand Side Make-Up Water – 1.5” Ball
Valve under Left Front Deck
(1) x 1.5” stand ard valve w/ auto-refill
flo
at inside
Included
3 Port FDC with (3) 2.5” Brass
Clappered Snoots with
Pressure Relief Valve
Plumbed to fittings inside providing
150’ of Line Restriction & Friction loss
and simulated Standpipe Hydrant
Included
Flexible Suction Hoses (2) - 6” Hoses 10’ in Length 6” Diameter with NH Threaded Fittings Included 1 Custom Portable Hydrant DB 4” x 2 ½” 6” Intake reduced to 4” FNH Swivel Included Electro-mechanical Water Meter 12 Volt with Battery Conditioner Plum bed on 6” Blue Suction Pipe -Front Included Roof Target 5’ x 5’ Galvanized Inset into Roof top for Drainage Mult i-Layer Galvanized Steel - Strength Included Swinging Nozzle Flow Targets Powder coated Stainless Steel Mounted to Diffuser Screen Included Tool/ Parts Box Blue Powder coat Included
Base Model Total: $96,775.00
Accessories / Options:
Pump Testing Manifold Manifold mounted on Left
Side (4) 2 ½” Fittings with
Caps connected to flanged
flow assembly.
Dept. will attach their Stream
Straightener fitting and Pitot
Gauge, water flows into open Tank.
$3,800.00
Add-on & Options Sub-Total: $3,800.00
Sub-Total before Sales Tax: $100,575.00
Sales Tax: Zip Code: 95020 9.0 % Sales Tax $9,051.75
Total after Sales Tax: $109,626.75
On-Site Training & Delivery: Provided by PumpPodUSA Training & Delivery $1,450.00 Grand Total: $111,076.75
Payment Installments: Please make the checks payable to:
Initial 50% Payment Due with Issued P.O. PumpPodUSA
Remaining 50% upon Delivery 3850 Royal Ave., Suite B
Simi Valley – CA – 93063
ATTACHMENT B
www.PumpPodUSA.com
June 20, 2023
Stockton Fire Department Quote #: 23-0620SFDMDU-01
Mobile DRAFTS UNIT Proposal
Dear Deputy Chief Brandon Doolan,
Thank you for your interest in our PumpPodUSA DRAFTS UNITS. We are pleased to present the following information per your request for a Mobile DRAFTS Unit (exceeds 2,100 USG). The PumpPodUSA - Direct Recirculating Apparatus Firefighting Training & Sustainability (DRAFTS) Unit apparatus is specifically designed to be the ultimate training tool to develop, maintain and test your Engineers and Firefighters. This Unit will enhance the safety, training and practice for candidates specifically while providing needed additional training opportunities to ensure that your department has the most prepared and qualified workforce today.
The DRAFTS Unit will provide and allow your department to train with Full Flow Water for your Firefighters and Engineers. When deployed out into the Battalions the Engine Companies can train WITHOUT having to call “Out of Service” thus significantly increasing the hours of training but reducing time and costs related to these exercises.
Another benefit to the DRAFTS Units is that they are self-contained and re-circulate the water required for a wide variety of training evolutions as well as a host of NFPA testing requirements and water conservation mandated compliance.
Each DRAFTS Unit will allow approximately (2,100 USG) amount of water to be pump continually, literally saving millions of gallons each year using the DRAFTS Units innovative design and construction.
General Construction Notes:
x This apparatus is constructed are custom fabricated from scatch and are reinforced in a variety of ways in order to provide long term reliability and durable service. x A custom bulkhead is constructed and welded into the container. This bulkhead is placed back from the access doors. The design also allows a safe flat deck to safely access to the nozzle mounting system. This system is customizable to suit your Training & Testing needs. variety of straight nozzle styles as well as custom additions.
x The DRAFTS UNIT is fitted with Drafting and Pressure Pipes, NH Fittings of various sizes ranging from:
1 1/2” - 6” and is available in several configurations based on your department needs. x The Diffuser Screen is mounted to a frame at an angle to divert the incoming stream downward into the reservoir. The optional hanging targets on the deflector shield are to help train nozzle operators. x All Apparatus will be coated internally with Rhino protective coatings for containment and durability. x Photographs and illustrations are included on the following pages to help illustrate the design items mentioned herein.
x 10 Year Limited Warranty
Thank you again for your interest, after your review please feel free to contact me with any questions or comments.
Sincerely,
Bill Ward
Executive Director Cell: (949)246 6999 Email: [email protected]
ATTACHMENT B
www.PumpPodUSA.com
Mobile DRAFTS Unit on 24’ Trailer Capacity: 2,100 Gallons Approx. Gross Weight (Empty): 9,700 lbs. Example: How Artwork has been applied on previous Units.
ATTACHMENT B
www.PumpPodUSA.com
DIRECT RECIRUCLING APPARATUS FIREFIGHTER
TRAINING & SUSTAINABILITY UNIT
Rear Bulkhead Wall & Interior Features:
1 G a l v a n i z e d D i f f u s e r S creen mounted to Aluminum Frame (Optional Target can be mounted) 1 S t e p w e l d e d t o I n s i d e and outside of the Bulkhead Wall 6 Welded Fire Hose & Nozzle Plates in 2.5” Ss Ni pples Capped with 2.5” NH Fittings (Aluminum) 1 200 PSI Pressure Relief Valve for FDC Plumbing (Red)
1 1 ½” Valve, the same as if they were opening of Interior Standpipe on 3 rd floor (Red) (Connected to 3 Port FDC with In-line 900 Fittings to provide for the equivalent of 150’of resistance/ friction loss)
ATTACHMENT B
www.PumpPodUSA.com
Front:
1 Safety Rail with folding Aluminum Step at front of Deck 1 6” Horizontal Draft Port (Blue) with Butter fly Valve and 6” FNH Double Swivel Fitting (Alum.) 1 6” Vertical Riser Draft Training Riser per our discussion, (for a portion of annual pump testing) 1 1 ½” Make-up Water (using an Auto-Fill with Floa t) Ball Valve with NH fitting - - Right side 1 Powder Coated Blue Parts Box
1 12 Volt Electromechanical Water Meter with Tota lizer with 12 Battery & Conditioner w/ Plugin. 1 Portable Hydrant with Stainless Steel deck plate to secure to unit to the deck during transport. 1 (3) Port FDC with 2 ½”Clap pered Snoots w/ working 3rd Story Standpipe valve with 200 PSI PRV. (Plumbed to series of 90 degree fittings Providing for 150’ of Line Restriction / friction loss.
ATTACHMENT B
www.PumpPodUSA.com
Standard Items & Features Included:
(1) Portable Wet Barrel (DB) Customized Hyd rant 6” Supply (4”, 4 ½” or 5” reducer NH Fitting) in 2 or 3 Ports Multi-layer Galvanized Expanded Steel Deflector Screen secured to Aluminum Frame. (3) Port FDC Connections – Plumbed with (3) 2 ½” Brass Clappered Snoots 5’ x 5’ Galvanized Roof Target
Swinging Nozzle Target Plate Powder coated Yellow and bolted to Diffuser Screen Non-skid flooring welded on Rear deck level with Pod Floor with aluminum heavy duty non-skid decking.
Non-skid flooring welded on Front End Deck with expanded & raised Galvanized steel.
Powder Coated Front End Safety Rail with Aluminum Folding Step Rear Stairs – Folding Aluminum with Web Strap Set for transport. Upper Handles coated with Rhino Liner.
Powder Coated Rear Deck Safety Railing -
3” Floor Drain – Nylon Ball valve with Cam Fitting and 25’ of Lay Flat Drain Hose Interior of Apparatus sprayed with watertight Rhino Liner protective coating for containment and durability.
Exterior Powder Coated Panel Siding with aluminum diamond plate trim. Artwork / Signage using a UV Wrap.
All Ball Valve Handles coated with Black Rhino Liner protective coating Custom Heavy-Duty 12” I-Beam with dual axle Trailer for PumpPod DRAFTS Unit(Painted Black with Clear Coat) Optional Items & Features
Additional - Portable Wet Barrel Customized Jones Hydrant (DB 4” x 2 1/2”, DB 4” x 2 ½” x 2 ½”) Pump Testing Manifold (5) 3” Clappered Snoots for up to 2,000 GPM Customized 3 Port Portable (DB 4” x 2 ½” x 2 ½”) Wet Barrel Jones Hydrant Fire Hose Roller (Inserted when needed into Hitch Receiver – welded on either side of Rear Portion of Trailer Warranty
10 Year Limited Warranty (See Warranty Document)
Repairs and Service of Units
Any Warranted Repairs or Non-Preventive Maintenance Service items covered by the warranty, will be performed by PumpPodUSA personnel or designated vendor. Written Notice with photographs documenting the Repair / Service Item in question shall be sent to PumpPodUSA in a timely manner from the Fire Department Fleet Services. Once PumpPodUSA reviews the issue they will decide on the course of action:
1. Local Vendor - Dispatched by PumpPodUSA… (If Item is not completed by Vendor - Refer to Option #2)
2. PumpPodUSA personnel will be dispatched to inspect and perform Repairs or Service on-site.
3. If Repair & Service Item(s) can’t be completed on-site the Unit will be transported to the factory at the manufactures time and expense. Once Repair / Service are completed it will be returned back to Fire Department at manufactures expense.
4. Fire Department Fleet representative will confirm Item in question was completed to Departments satisfaction must be signed off at time of delivery.
ATTACHMENT B
www.PumpPodUSA.com
Price Quote Da t e : J u n e 2 0 , 2 0 2 3
St
ockton Fire Department Quote #: 23-0620SFDMDU-01
Pump-Pod / DRAFTS Unit Specifications: Descriptions Unit Price:
(1) Mobile –
Approx. 2,100 Gallons
See the Following List:
Mobile Base Model
Mobile DRAFTS Unit
(see specifications above)
$96,775.00
Stenciling & Artwork Signage
Wrap
Seals, Shields & Logos -
Digital files provided by Cust.
Wrap Designed, Printed and Applied
by PumpPodUSA
Included
Diffuser Screen Layered Expanded Galvanized Secured to Aluminum Frame Included Bulkhead Inside Rear Door (1) Weld ed Step on Outside (1) Weld ed Step to Inside of Bulkhead Included (6) – 2.5” Ss Pipe Nipples
Weld
ed on Nozzle Plates
2.5” NST Fittings on each nipple Included
Front Deck 6” Butterfly Valve on Primary
Horizontal D
rafting Connection
6” FNPT to 6” FNH Dbl. Swivel Fitting
W /6” MNST x 4” FNST Swivel reducer
Included
On vertical Draft Riser –
Material Sch
ed. 80 PVC
6” FNPT to 6” MNH Fitting
Convert from Pipe to Fire Hose Threads
1” Bleeder Valve on Riser
Included
Front - Left Hand Side Make-Up Water – 1.5” Ball
Valve under Left Front Deck
(1) x 1.5” stand ard valve w/ auto-refill
flo
at inside
Included
3 Port FDC with (3) 2.5” Brass
Clappered Snoots with
Pressure Relief Valve
Plumbed to fittings inside providing
150’ of Line Restriction & Friction loss
and simulated Standpipe Hydrant
Included
Flexible Suction Hoses (2) - 6” Hoses 10’ in Length 6” Diameter with NH Threaded Fittings Included 1 Custom Portable Hydrant DB 4” x 2 ½” 6” Intake reduced to 4” FNH Swivel Included Electro-mechanical Water Meter 12 Volt with Battery Conditioner Plum bed on 6” Blue Suction Pipe -Front Included Roof Target 5’ x 5’ Galvanized Inset into Roof top for Drainage Mult i-Layer Galvanized Steel - Strength Included Swinging Nozzle Flow Targets Powder coated Stainless Steel Mounted to Diffuser Screen Included Tool/ Parts Box Blue Powder coat Included
Base Model Total: $96,775.00
Accessories / Options:
Pump Testing Manifold Manifold mounted on Left
Side (4) 2 ½” Fittings with
Caps connected to flanged
flow assembly.
Dept. will attach their Stream
Straightener fitting and Pitot
Gauge, water flows into open Tank.
$3,800.00
Add-on & Options Sub-Total: $3,800.00
Sub-Total before Sales Tax: $100,575.00
Sales Tax: Zip Code: 95020 9.0 % Sales Tax $9,051.75
Total after Sales Tax: $109,626.75
On-Site Training & Delivery: Provided by PumpPodUSA Training & Delivery $1,450.00 Grand Total: $111,076.75
Payment Installments: Please make the checks payable to:
Initial 50% Payment Due with Issued P.O. PumpPodUSA
Remaining 50% upon Delivery 3850 Royal Ave., Suite B
Simi Valley – CA – 93063
ATTACHMENT B
YR JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC ANNUAL 1 2023 53 50 56 64 60 125 0 0 0 0 0 0 408
22 0 2 2 63 52 47 75 95 166 180 150 175 139 134 58 1334 32 0 2 1 50 96 98 98 141 201 170 169 136 139 123 57 1478 42 0 2 0 41 45 42 51 78 150 191 93 112 207 117 50 1177
5 2019 45 49 48 45 69 76 126 107 196 105 61 55 982
5 Year 5379
ATTACHMENT B