Cities Index.
Attachment D - Conceptual Project Plans

City Council and Concurrent Authorities
November 4, 2025

Document
Attachment D - Conceptual Project Plans
Meeting
November 4, 2025
Body
City Council and Concurrent Authorities
Original file
10.4 MB
Text extracted from the city's file for reading and search. Open the original on legistar1.granicus.com. That file is the official record.

(209) 522-8031 - fax: (209) 522-4738 - www.odcengr.com
Oakdale, CA 95361
145 N. 2nd Street, Ste. 5
Owens Design Consultants

SITE PLAN
N
NORTH

PAVING SECTION THICKNESS

GENERAL CONDITIONS

GENERAL NOTES

PARKING REQUIREMENTS

SITE LEGEND KEY NOTES

BENCHMARKBASIS OF BEARING

LEGAL DESCRIPTION
’
’ ’
’ ’

SITE PLAN
SD1.0

THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO

PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES THAT MAY BE AT THE SITE. IT SHALL BE THE

CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED AND CALL USA ALERT 1-800-227-2600 BEFORE STARTING WORK. THE EXISTENCE AND APPROXIMATE LOCATION OF

UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS WERE DETERMINED FROM EXISTING RECORDS. HOWEVER, THERE MAY BE OTHER UTILITIES AND/OR STRUCTURES IN THE AREA.

ATTACHMENT D
(209) 522-8031 - fax: (209) 522-4738 - www.odcengr.com
Oakdale, CA 95361
145 N. 2nd Street, Ste. 5
Owens Design Consultants

OFF SITE IMPROVEMENT PLAN
N
NORTH

PAVING SECTION THICKNESS

GENERAL CONDITIONS

GENERAL NOTES

PARKING REQUIREMENTS

SITE LEGEND KEY NOTES

BENCHMARKBASIS OF BEARING

LEGAL DESCRIPTION
’
’ ’
’ ’

OFF SITE

IMPROVEMENT
PLAN
SD1.3

THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO

PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES THAT MAY BE AT THE SITE. IT SHALL BE THE

CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED AND CALL USA ALERT 1-800-227-2600 BEFORE STARTING WORK. THE EXISTENCE AND APPROXIMATE LOCATION OF

UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS WERE DETERMINED FROM EXISTING RECORDS. HOWEVER, THERE MAY BE OTHER UTILITIES AND/OR STRUCTURES IN THE AREA.

ATTACHMENT D
90°120°

49.023ftMin Radius
(Outer Wheel)

50.751ftMin Radius(Outer Body)

13.185ft
Max Kickout 0.042ft
60°
90°

49.023ftMin Radius
(Outer Wheel)

50.751ftMin Radius(Outer Body)

13.185ft
Max Kickout 0.042ft90°

49.023ftMin Radius(Outer Wheel)

50.751ftMin Radius
(Outer Body)

13.185ft
Max Kickout 0.042ft
(209) 522-8031 - fax: (209) 522-4738 - www.odcengr.com
Oakdale, CA 95361
145 N. 2nd Street, Ste. 5
Owens Design Consultants

TRAFFIC ANALYSIS PLAN
N
NORTH

PAVING SECTION THICKNESS

GENERAL CONDITIONS

GENERAL NOTES

PARKING REQUIREMENTS

SITE LEGEND

LEGAL DESCRIPTION
’
’ ’
’ ’

TRAFFIC

ANALYSIS
PLAN
SD1.4

THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO

PROTECT THE UTILITIES OR STRUCTURES SHOWN AND ANY OTHER UTILITIES OR STRUCTURES THAT MAY BE AT THE SITE. IT SHALL BE THE

CONTRACTOR'S RESPONSIBILITY TO NOTIFY THE OWNERS OF THE UTILITIES OR STRUCTURES CONCERNED AND CALL USA ALERT 1-800-227-2600 BEFORE STARTING WORK. THE EXISTENCE AND APPROXIMATE LOCATION OF

UNDERGROUND UTILITIES OR STRUCTURES SHOWN ON THESE PLANS WERE DETERMINED FROM EXISTING RECORDS. HOWEVER, THERE MAY BE OTHER UTILITIES AND/OR STRUCTURES IN THE AREA.

ATTACHMENT D

ATTACHMENT D
A101

ENLARGED TRASH

ENCLOSURE PLAN
AND ELEVATIONS 1SCALE: 1/4" = 1'-0"

ENLARGED TRASH ENCLOSURE PLAN
TRUE
NORTH
E. CASTILLO
D. BURKETT
1234
C
B
A
THIS SHEET INTENDED TO BE 24"x36". DO NOT SCALE DRAWING.

SHEET NUMBER

SHEET TITLE
CHECKED BY:

COPYRIGHT: © RED INC

PROJECT REVISIONS
AHJ:

RED PROJECT NO:

PROJECT DETAILS
1217 J STREET
MODESTO, CA 95354
209.522.8900
WWW.REDINCARCHITECTS.COM

CONSULTING ENGINEER

ARCHITECT OF RECORD

JACK IN THE BOX
9350 THORNTON RD.

CITY OF STOCKTON
25021
STOCKTON, CA. 95209
# DATE DESCRIPTION
PERMIT:XXXXX
APN:XXX-XXX-XXX
SUBMITTAL DATE:-
2025
P:\2025\25021 Jack in the Box Stockton\03 Design - CD's\02 Planning\A101 Enlarged stie plan.dwg 6-27-25 11:08:08 AM Edgar DRAWN BY:
12'-8"
10'-4"
6'-8"
2'-0"
19'-0"
2'-0" 8'-8" 2'-0"
8" SPLIT FACE CMU. SOLID

GROUT WALL
2SCALE: 1/2" = 1'-0"

TRASH ENCLOSURE ELEVATION - WEST
3SCALE: 1/2" = 1'-0"

TRASH ENCLOSURE ELEVATION - EAST
4SCALE: 1/2" = 1'-0"

TRASH ENCLOSURE ELEVATION - NORTH/SOUTH
GROUND
0'-0"
T.O. CMU WALL
6'-0"
GROUND
0'-0"
T.O. CMU WALL
6'-0"
GROUND
0'-0"
T.O. CMU WALL
6'-0"

PAINT EXTERIOR

TO MATCH SW
7005 "PURE
WHITE"
12'-8"
10'-4"
8" SPLIT FACE CMU. SOLID

GROUT WALL

PAINT EXTERIOR TO
MATCH SW 7005 "PURE
WHITE"
8" SPLIT FACE CMU. SOLID

GROUT WALL

PAINT EXTERIOR TO
MATCH SW 7005 "PURE
WHITE"
12'-8"
8" 11'-4" 8"

ATTACHMENT D
DARK BRONZE ANODIZED ALUMINUMPAINTED STUCCO ASSEMBLY:

SMOOTH STUCCO, COLOR TO MATCH -
SW 7588 "SHOW STOPPER"
PAINTED STUCCO ASSEMBLY:

SMOOTH STUCCO, COLOR TO MATCH -
SW 7005 "PURE WHITE"
THIN BRICK VENEER ASSEMBLY:

WIRE CUT -
"MIDNIGHT"
PAINTED STUCCO ASSEMBLY:

SMOOTH STUCCO, COLOR TO MATCH -
SW 6832 "IMPULSIVE PURPLE"
AC
JN
H

EXTERIOR FINISHES

MATERIAL BOARD
9350 THORNTON RD.

STOCKTON, CA 95209
APN: 072-450-26
WALL TILE 12"X35":

COLOR TO MATCH -
"JIB RED" CUSTOM COLOR PER TILE

MANUFACTURER
P
METAL CANOPY:

PRE FABRICATED, COLOR TO MATCH -
SW 6832 "IMPULSIVE PURPLE"
G

ATTACHMENT D

← All documents from this meeting