69 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
08.05. 2022
# REVISION LIST
ANDREA COCHRAN
LANDSCAPE ARCHITEC
2325 Third Street #210
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
1/16" = 1'-0"
IRRIGATION DETAILS
Irrigation Consultant:
2760 Camino Diablo
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
REFER TO
IRRIGATION
LEGEND
4"
1 FINISH GRADE
3 4
5 8
7 6
9 2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
1 8
2 3
6 TORO TRI-LOC ELBOW
(TL-E)
5 7
4 DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
21 SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 7
9 2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
5 7
DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
LANDSCAPE - IRRIGATION
NOTES & DETAILS - L509
Attachment 5
70 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
WATER TYPE POTABLE
SITE ETO= 45.5
9/29/2022
HYDROZONE # HYDROZONE NAME PLANT WATER
USE TYPE
PLANT
FACTOR (PF)
IRRIGATION
METHOD
IRRIGATION
EFFICIENCY ETAF (PF/IE) AREA (SQ. FT)
(HA) ETAF X AREA (HA) ETWU
(GAL/YR)
ACRE FEET/
YEAR HCF/ YEAR PERCENTAGE OF
LANDSCAPE
1 GROUNDCOVER LOW 0.3 DRIP 0.81 0.37 4,689 1,737 48,991 0.15 65.50 15% 2 SHRUBS MOD 0.5 DRIP 0.81 0.62 2,276 1,405 39,633 0.12 52.99 7% 2 SHRUBS LOW 0.3 DRIP 0.81 0.37 5,008 1,855 52,324 0.16 69.95 16% 3 TREES LOW 0.3 RINGS 0.81 0.37 2,200 815 22,986 0.07 30.73 7% 4 TREES MOD 0.5 RINGS 0.81 0.62 2,200 1,358 38,310 0.12 51.22 7% 5 STORMWATER MOD 0.5 SPRAY 0.75 0.67 2,666 1,777 50,139 0.15 67.03 8% 6 VINE MOD 0.5 BUBBLER 0.81 0.62 126 78 2,194 0.01 2.93 0% 7 GRASS PLUGS HIGH 0.7 SPRAY 0.75 0.93 2,101 1,961 55,318 0.17 73.95 7% 8 PLANTING AREA 1 MOD 0.5 DRIP 0.81 0.62 6,269 3,870 109,166 0.34 145.94 20% 9 PLANTING AREA 2 LOW 0.3 DRIP 0.81 0.37 3,228 1,196 33,727 0.10 45.09 10% 10 POOL/SPA HIGH 0.7 1 1,025 3%
31,788 16,051 452,788 1.39 605.33 100%
HYDROZONE # HYDROZONE NAME
1 0%
TOTALS 0 0%
493,207
1.51 659.37
452,788 ETo = REFERENCE EVAPOTRANSPIRATION ETo = REFERENCE EVAPOTRANSPIRATION
1.39 0.45= ET ADJUSTMENT FACTOR PF = PLANT FACTOR FOR HYDROZONES 605.33 LA=LANDSCAPED AREA (SQUARE FEET) HA = HYDROZONE AREA (SQ.FT)
SITE IRRIGATION
EFFICIENCY SITE PLANT FACT0R
MAWA
COMPLIANT IE = IRRIGATION EFFICIENCY (0.81)-BUBBLER/DRIP
80.7% 0.42 YES IE = IRRIGATION EFFICIENCY (0.75)-ROTORS/SPRAY TOTAL ETAF x AREA 16,051
TOTAL AREA 31,788
AVG. ETAF 50.49%
REGULAR LANDSCAPE AREAS
GALLONS/YR
ETWU
ETAF Calculations
WATER USE ESTIMATION-Kifer Development -Ground, 4th and 8th Floor LVL-Sunnyvale
SPECIAL LANDSCAPE AREAS
REGULAR LANDSCAPE AREAS
ACRE FEET/YR
HCF/YR
MAWA
ETWU= ((ETO)(.62)(ETAF x LA))MAWA = (ETo)(0.62)[(LA x 0.55) + (0.45 x SLA)]
ETWU FORMULA
TOTALS
MAXIMUM APPLIED WATER ALLOWANCE (MAWA)
GALLONS PER YEAR
0.62 = CONVERSION FACTOR (GALLONS/SQ.FT/YR)0.62 = CONVERSION FACTOR (GALLONS/SQ.FT/YR)
ACRE FEET/YR
HCF/YR
MAWA FORMULA
GALLONS/YR
ESTIMATED TOTAL WATER USE (ETWU) GALLONS PER
YEAR
SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 7
9 2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
5 7
DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
LANDSCAPE - IRRIGATION
WATER CALCULATIONS - L510
Attachment 5
71 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE - WATER EFFICIENT CHECKLIST
PROPOSED LOT 2 OFFICE L.O.W.
Attachment 5
72 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE - WATER EFFICIENT CHECKLIST
PROPOSED LOT 1 RESIDENTIAL
Attachment 5
73 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE SITE PLAN
1/32” = 1’-0”
HYDROZONE PLAN 1 OF 2
LOW 4,501 SF
-
MEDIUM 4,291 SF
-
CONCEPT PLANT SCHEDULE OFFICE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 20
# REVIS
KIFER DEVELOPMENT
NOT FOR
1/16" = 1
HYDROZONE
SHEET L601 SHEET L601
SEE SHEET 2 OF 2 SEE SHEET 2 OF 2
LOW 4,501 SF
-
MEDIUM 4,291 SF
-
CONCEPT PLANT SCHEDULE OFFICE
SHEET N
SHEET T
ISSUES
PROJECT
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
#
HYD
SHEET L601 SHEET L601
Attachment 5
74 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE SITE PLAN
1/32” = 1’-0”
HYDROZONE PLAN 2 OF 2
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
DN
UP
UP
DN
DN
UP
UP
UP
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
LOW 6,647 SF
-
HIGH 2,218 SF
-
MEDIUM 2,844 SF
-
CONCEPT PLANT SCHEDULE PROJECT SITE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
HYDROZONE P
SHEET L600 SHEET L600
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
DN
UP
UP
DN
DN
UP
UP
UP
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
LOW 6,647 SF
-
HIGH 2,218 SF
-
MEDIUM 2,844 SF
-
CONCEPT PLANT SCHEDULE PROJECT SITE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
#
N
1 HYDROZ
Attachment 5
75 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLAN LEVEL 4
1/32” = 1’-0”
HYDROZONE PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
2 A300
1 A300
1 A400
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
LOW 3,530 SF
-
MEDIUM 1,466 SF
-
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
HYDROZONE P
LEVEL 4
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
2 A300
1 A300
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
LOW 3,530 SF
-
MEDIUM 1,466 SF
-
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
# REVISION L
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
HYDROZONE P
LEVEL 4
Attachment 5
76 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLAN LEVEL 8
1/32” = 1’-0”
HYDROZONE PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
2 A300
1 A300
1 A400
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
LOW 220 SF
-
MEDIUM 65 SF
-
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
HYDROZONE P
LEVEL 8
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
2 A300
1 A300
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
LOW 220 SF
-
MEDIUM 65 SF
-
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
# REVISION
KIFER DEVELOPMENT
NOT FOR CO
1/16" = 1'-0"
HYDROZONE P
LEVEL 8
Attachment 5
77 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
TREE #709
TREE #705
TREE #560
TREE #656
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702
TREE #697
TREE #704
TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
TREE #561
TREE #562
NO TAG
TREE - MEDIUM - 36" BOX 1
NYSSA SYLVATICA `WILDFIRE`
ACER CIRCINATUM
TREE - LOW - 36" BOX 5
AESCULUS CALIFORNICA
CERCIS OCCIDENTALIS `ALBA`
EXISTING TREE 16
VINE - MEDIUM - 5 GAL. - TRAINED ON STAKE 16
FICUS PUMILA
CONCEPT PLANT SCHEDULE OFFICE
GROUND COVER - 1 GAL. 1,916 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
PLANTING AREA - MEDIUM - 5 GAL. 4,291 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 2,585 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT` - LOW
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 20
# REVIS
KIFER DEVELOPMENT
NOT FOR
1/16" = 1
PLANTING P
SHEET L601 SHEET L601
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
TREES ARE 36" BOX.
SEE SHEET 2 OF 2 SEE SHEET 2 OF 2
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
TREE #709
TREE #705
TREE #560
TREE #656
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702
TREE #697
TREE #704
TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
TREE #561
TREE #562
NO TAG
TREE - MEDIUM - 36" BOX 1
NYSSA SYLVATICA `WILDFIRE`
ACER CIRCINATUM
TREE - LOW - 36" BOX 5
AESCULUS CALIFORNICA
CERCIS OCCIDENTALIS `ALBA`
EXISTING TREE 16
VINE - MEDIUM - 5 GAL. - TRAINED ON STAKE 16
FICUS PUMILA
CONCEPT PLANT SCHEDULE OFFICE
GROUND COVER - 1 GAL. 1,916 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
PLANTING AREA - MEDIUM - 5 GAL. 4,291 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 2,585 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT` - LOW
SHEET N
SHEET T
ISSUES
PROJECT
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
#
PLAN
SHEET L601 SHEET L601
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
TREES ARE 36" BOX.
LANDSCAPE SITE PLAN
1/32” = 1’-0”
PLANTING PLAN 1 OF 2
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
TREE #709
TREE #705
TREE #560
TREE #656
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702
TREE #697
TREE #704
TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
TREE #561
TREE #562
NO TAG
1 `
5 `
16 NED ON STAKE 16
GROUND COVER - 1 GAL. 1,916 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
PLANTING AREA - MEDIUM - 5 GAL. 4,291 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 2,585 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT` - LOW
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L600
1/16" = 1'-0"
PLANTING PLAN
SHEET L601
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
TREES ARE 36" BOX.
Attachment 5
78 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLANT IMAGES
GROUND LEVEL OFFICE PROPOSED PLANTING SHEET 1 OF 2
Tree Medium - 36” BOX
Nyssa sylvatica ‘Wildfire’
Tree Medium - 36” BOX
Acer circinatum
Tree Low - 36” BOX
Aesculus californica
Tree Low - 36” BOX
Cercis occidentalis ‘Alba’
Vine - Medium - 5 Gal
Trained on Stake
Ficus pumila
Ground Cover - 1 Gal.
Fragaria vesca - Medium
Ground Cover - 1 Gal.
Rhamnus Californica ‘Eve
Case’ - Low
Ground Cover - 1 Gal.
Arctostaphylos ‘Pacific Mist’
- Low
Ground Cover - 1 Gal.
Dymondia margaretae - Low
Plant Area - Medium - 5 Gal.
Pittosporum tenuifolium
‘Silver Sheen’
Plant Area - Low - 5 Gal.
Ceanothus griseus var. hori-
zontalis ‘Yankee Point’
Plant Area - Low - 5 Gal.
Olea europaea Little Olle -
Very Low
Attachment 5
79 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
Plant Area - Low - 5 Gal
Muhlenbergia dubia
Plant Area - Low - 5 Gal
Achillea millefolium
Plant Area - Low - 5 Gal
Lomandra longifolia Breeze
Plant Area - Low - 5 Gal
Agave ‘Blue Flame’
Plant Area - Low - 5 Gal
Melianthus major ‘Antanow’s
Blue’
Plant Area - Low - 5 Gal
Lomandra ’Platinum beauty’
Plant Area - Low - 5 Gal
Acacia cognata ‘Cousin Itt’
LANDSCAPE PLANT IMAGES
GROUND LEVEL OFFICE PROPOSED PLANTING SHEET 2 OF 2
Attachment 5
80 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 37
LANDSCAPE SITE PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
DN
UP
UP
DN
DN
UP
UP
UP
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
TREE #560
TREE
#539
TREE
#552
TREE
#553
TREE
#554
TREE
#555
TREE
#556
TREE
#557
TREE
#558
15'-0"
LANDSCAPE
FRONTAGE STRIP
SHADE TREE - 36" BOX 8
GINKGO BILOBA COLUMNAR
ACER X FREEMANII
TREE - MEDIUM - 36" BOX 14
NYSSA SYLVATICA `WILDFIRE`
ACER CIRCINATUM
TREE - LOW - 36" BOX 20
AESCULUS CALIFORNICA
CERCIS OCCIDENTALIS `ALBA`
EXISTING TREE 8
CONCEPT PLANT SCHEDULE PROJECT SITE
SHRUB - MEDIUM - 5 GAL. 138
BUXUS SEMPERVIRENS `MONRUE` TM
SHRUB - LOW - 5 GAL. 152
RHAMNUS ALATERNUS `JOHN EDWARDS`
VINE - MEDIUM - 5 GAL. - TRAINED ON STAKE 26
FICUS PUMILA
GRASSES - LOW - 5 GAL. 107
DIETES GRANDIFLORA
LOMANDRA `PLATINUM BEAUTY`
STORMWATER 2,645 SF
CERCIS CANADENSIS - MEDIUM 36" BOX
CHRONDROPETALUM TECTORUM - LOW TO MEDIUM 5 GAL.
CORNUS SERICEA - HIGH 5 GAL.
CALYCANTHUS OCCIDENTALIS - MEDIUM 5 GAL.
JUNCUS PATENS `ELK BLUE` - LOW 5 GAL.
GROUND COVER - 1 GAL. 2,732 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
GRASSCRETE 2,115 SF
NATIVE GRASS PLUGS - HIGH
PLANTING AREA - MEDIUM - 5 GAL. 1,920 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 646 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT`
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
PLANTING PLAN
SHEET L600 SHEET L600
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
1/32” = 1’-0”
PLANTING PLAN 2 OF 2
SEE SHEET
1 OF 2
SEE SHEET
1 OF 2
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
DN
UP
UP
DN
DN
UP
UP
UP
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
TREE
#539
TREE
#552
TREE
#553
TREE
#554
TREE
#555
TREE
#556
TREE
#557
TREE
#558
15'-0"
LANDSCAPE
FRONTAGE STRIP
SHADE TREE - 36" BOX 8
GINKGO BILOBA COLUMNAR
ACER X FREEMANII
TREE - MEDIUM - 36" BOX 14
NYSSA SYLVATICA `WILDFIRE`
ACER CIRCINATUM
TREE - LOW - 36" BOX 20
AESCULUS CALIFORNICA
CERCIS OCCIDENTALIS `ALBA`
EXISTING TREE 8
CONCEPT PLANT SCHEDULE PROJECT SITE
SHRUB - MEDIUM - 5 GAL. 138
BUXUS SEMPERVIRENS `MONRUE` TM
SHRUB - LOW - 5 GAL. 152
RHAMNUS ALATERNUS `JOHN EDWARDS`
VINE - MEDIUM - 5 GAL. - TRAINED ON STAKE 26
FICUS PUMILA
GRASSES - LOW - 5 GAL. 107
DIETES GRANDIFLORA
LOMANDRA `PLATINUM BEAUTY`
STORMWATER 2,645 SF
CERCIS CANADENSIS - MEDIUM 36" BOX
CHRONDROPETALUM TECTORUM - LOW TO MEDIUM 5 GAL.
CORNUS SERICEA - HIGH 5 GAL.
CALYCANTHUS OCCIDENTALIS - MEDIUM 5 GAL.
JUNCUS PATENS `ELK BLUE` - LOW 5 GAL.
GROUND COVER - 1 GAL. 2,732 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
GRASSCRETE 2,115 SF
NATIVE GRASS PLUGS - HIGH
PLANTING AREA - MEDIUM - 5 GAL. 1,920 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 646 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT`
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
#
N
1 PLANTIN
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
TREES ARE 36" BOX.
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
TREE #709
TREE #705
TREE #560
TREE #656
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702
TREE #697
TREE #704
TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
TREE #561
TREE #562
NO TAG
1 `
5 `
16 NED ON STAKE 16
GROUND COVER - 1 GAL. 1,916 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
PLANTING AREA - MEDIUM - 5 GAL. 4,291 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 2,585 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT` - LOW
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L600
1/16" = 1'-0"
PLANTING PLAN
SHEET L601
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
TREES ARE 36" BOX.
Attachment 5
81 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLANT IMAGES
GROUND LEVEL SITE PROPOSED PLANTING SHEET 1 OF 2
Shade Tree - 36” BOX
Ginkgo Biloba Columnar
Shade Tree - 36” BOX
Acer x Freemanii
Tree Medium - 36” BOX
Nyssa Sylvatica ‘ Wildfire’
Tree Medium - 36” BOX
Acer Circinatum
Tree Low - 36” BOX
Aesculus californica
Tree Low - 36” BOX
Cercis occidentalis ‘Alba’
Shrub - Medium - 5 Gal
Buxus sempervirens ‘Monrue’
Grasses - Low - 5 Gal
Dietes grandiflora
Shrub - Low - 5 Gal
Rhamnus alaternus
‘John Edwards’
Vine - Medium - 5 Gal
Trained on Stake
Ficus pumila
Grasses - Low - 5 Gal
Lomandra ‘Platinum Beauty’
Attachment 5
82 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLANT IMAGES
Stormwater
Cercis canadensis
Medium - 36” Box
Stormwater
Chrondropetalum tectorum
Low to Medium - 5 Gal
Stormwater
Cornus Sericea
High - 5 Gal
Stormwater
Calycanthus occidentalis
Medium - 5 Gal
Stormwater
Juncus patens ‘Elk Blue’
Low - 5 Gal
Ground Cover - 1 Gal.
Fragaria Vesca - Medium
Grasscrete
Native Grass Plugs - High
Ground Cover - 1 Gal.
Arctostaphylos ‘Pacific Mist’
Low
Ground Cover - 1 Gal.
Rhamnus californica ‘ Eve
Case’ - Low
Ground Cover - 1 Gal.
Dymondia margaretae - Low
GROUND LEVEL SITE PROPOSED PLANTING SHEET 2 OF 2
Attachment 5
83 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 38
LANDSCAPE PLAN LEVEL 4
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
EASEMENTS SEE CIVIL PLANS
4TH LVL TREE - MEDIUM 23
BETULA NIGRA - MEDIUM TO HIGH
ACER CIRCINATUM - MEDIUM
AESCULUS X CARNEA - MEDIUM
4TH LVL TREE - LOW 24
LAURUS NOBILIS `SARATOGA` - LOW
OLEA EUROPAEA ‘SWAN HILL’ - LOW
4TH LVL PLANTING AREA - MEDIUM 1,466 SF
SESLERIA AUTUMNALIS - MEDIUM
4TH LVL PLANTING AREA - LOW 3,530 SF
LAURUS NOBILIS - LOW
OLEA EUROPAEA `LITTLE OLLIE` - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
PLANTING PLAN
1/32” = 1’-0”
PLANTING PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
EASEMENTS SEE CIVIL PLANS
4TH LVL TREE - MEDIUM 23
BETULA NIGRA - MEDIUM TO HIGH
ACER CIRCINATUM - MEDIUM
AESCULUS X CARNEA - MEDIUM
4TH LVL TREE - LOW 24
LAURUS NOBILIS `SARATOGA` - LOW
OLEA EUROPAEA ‘SWAN HILL’ - LOW
4TH LVL PLANTING AREA - MEDIUM 1,466 SF
SESLERIA AUTUMNALIS - MEDIUM
4TH LVL PLANTING AREA - LOW 3,530 SF
LAURUS NOBILIS - LOW
OLEA EUROPAEA `LITTLE OLLIE` - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
# REVISION L
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
PLANTING PLAN
Attachment 5
84 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLANT IMAGES
4TH LEVEL PROPOSED PLANTING
4th Lvl Tree - Medium
Betula nigra
4th Lvl Tree - Medium
Acer circinatum
4th Lvl Tree - Medium
Aesculus x carnea
4th Lvl Tree - Low
Laurus nobilis ‘Saratoga’
4th Lvl Tree - Low
Olea europaea ‘Swan Hill’
4th Lvl Plant Area - Medium
Sesleria autumnalis
4th Lvl Plant Area - Low
Laurus nobilis - Low
4th Lvl Plant Area - Low
Olea europaea ‘Little Ollie’
4th Lvl Plant Area - Low
Muhlenbergia dubia
4th Lvl Plant Area - Low
Achillea millenfolium
Attachment 5
85 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 39
LANDSCAPE PLAN LEVEL 8
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
EASEMENTS SEE CIVIL PLANS
8TH LVL PLANTING AREA - LOW - 5 GAL. 220 SF
LAURUS NOBILIS - LOW
OLEA EUROPAEA `LITTLE OLLIE` - VERY LOW
AGAVE `BLUE FLAME` - LOW
8TH LVL PLANTING AREA - MEDIUM - 5 GAL. 65 SF
SESLERIA AUTUMNALIS - MEDIUM
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
PLANTING PLAN
1/32” = 1’-0”
PLANTING PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
EASEMENTS SEE CIVIL PLANS
8TH LVL PLANTING AREA - LOW - 5 GAL. 220 SF
LAURUS NOBILIS - LOW
OLEA EUROPAEA `LITTLE OLLIE` - VERY LOW
AGAVE `BLUE FLAME` - LOW
8TH LVL PLANTING AREA - MEDIUM - 5 GAL. 65 SF
SESLERIA AUTUMNALIS - MEDIUM
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
# REVISION
KIFER DEVELOPMENT
NOT FOR CO
1/16" = 1'-0"
PLANTING PLA
Attachment 5
86 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLANT IMAGES
8TH LEVEL PROPOSED PLANTING
8th Lvl Planting Area - Low
Laurus nobilis
8th Lvl Planting Area - Low
Olea europaea ‘Little Ollie’
8th Lvl Planting Area - Low
Agave ‘Blue Flame’
8th Lvl Planting Area - Medium
Sesleria autumnalis
Attachment 5
87 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 37
LANDSCAPE SITE PLAN
1/32” = 1’-0”
DN
UP
UP
DN
DN
UP
UP
UP
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 27
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 20
# REVIS
AND
LAN
2325
San
415.
KIFER DEVELOPMENT
NOT FOR
1/16" = 1
LIGHTING PL
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
DN
UP
UP
DN
DN
UP
UP
UP
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 27
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2
# REV
KIFER DEVELOPMENT
NOT FO
1/16" =
LIGHTING P
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
DN
UP
UP
DN
DN
UP
UP
UP
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 27
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L801
1/16" = 1'-0"
LIGHTING PLAN
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
LIGHTING PLAN
Attachment 5
88 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 40
SCALE: 3/16” = 1’-0”
SECTION 1: NORTH TOWN HOUSE APPROACH
LANDSCAPE SECTIONS
SECTION 2: NORTH TOWN HOUSE APPROACH - STORMWATER
BUILDING
2'-0"
4'-6"
SIDEWALK
7'-11"
STORMWATERROADWAY
5'-8"
STORMWATER
VARIES 6'-0" TO
8'-0"
TOWNHOUSE
PORCH
NORTH BUILDING
FACADE
12" TO 28"
10'-4"
STORMWATER
4'-6"
SIDEWALK
11'-7"
LOADING ZONE
BUILDING
2'-0"
PROPERTY LINE
Attachment 5
89 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 41
SECTION 3: SHARED USE PATH SECTION 4: SAN ZENO PLAZA
LANDSCAPE SECTIONS
SCALE: 3/16” = 1’-0”
VINES AT SOUTH
BUILDING FACADE
9'-0"
PLANTING AREA
14'-0"
PERMEABLE
CONCRETE PAVING
SHARED USE PATHWAY
2'-0"
PLANTING
SOUTH PROPERTY
LINE
POLE LIGHT
PL
6'-0"
SIDEWALK
VARIES: 9' TO 19'
ENTRY PLAZA PERMEABLE
UNIT PAVERS
VARIES: 20' TO 27'
EXISTING REDWOOD BERM
SAN ZENO
WAY
PL
EAST PROPERTY
LINE
EAST FACE OF
BUILDING BEYOND
EAST FACE OF
BUILDING
Attachment 5
90 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
SECTION 6: BACKFLOW SCREENINGSECTION 5: TRANSFORMER SCREENING FENCE WITH VINES
PROPERTY LINE
10'-3"
GRASSCRETE
20'-0"
CONCRETE PAD
VINES TRAINED ON
U-SHAPE SLAT LOUVER
VERTICAL FENCE
1'-5"
PLANTING
STRIP
4'-6"
SIDEWALK
BUILDING
PAD MOUNT
TRANSFORMER 6'-0"
BUILDING
PROPERTY LINE
BFP - RPDA
HEDGE U-SHAPE SCREEN
29'-3"
PLANTING STRIP
4'-6"
SIDEWALK
9'-8" GROUND COVER
AROUND UTILITIES
2'-10"
HEDGE
SCREENING
16'-9"
GROUND COVER
6'-7"
SIDEWALK
SAN
ZENO
WAY
6'-0"
VISION TRIANGLE
WM
LANDSCAPE SECTIONS
SCALE: 3/16” = 1’-0”
Attachment 5
91 LU SUBMITTAL 05 JULY 05, 2023
ARCHITECTURE
Attachment 5
92 LU SUBMITTAL 05 JULY 05, 2023
10’ 20’ 40’ 80’
SCALE : 1” = 40’
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
EXISITING FIRE
HYDRANT
CL R.O.W.
CL R.O.W.
EXISITING TREES
TRANSFORMERS
PER CIVIL
15' - 0"
10' - 0"
12' - 5" 29' - 5"
10' - 0" SETBACK
15' - 0" SETBACK
SAN
ZEN
O WAY
AMENITY DECK AMENITY DECK
PRIMARY RESIDENTIAL
ENTRY
AMENITY DECK
AMENITY POOL DECKAMENITY COURTYARD
SECONDARY SHARED-USE PATH
397.9'
298.6'
212.3'
NEW TRASH
ENCLOSURE
133.5'
182.6'
40' CORNER VISION TRIANGLE
14' - 0"
SETB
ACK
17' - 11" PRO
POSED
8' - 0"
LOADING SPACE
SITE PLAN 1/20 SCALE
1" = 20'-0"LU36
1 SITE PLAN
N
CB
24" RC
P
24" RC
P
EASEMENTS SEE CIVIL PLANS
CB
24" RC
P
24" RC
P
EASEMENTS SEE CIVIL PLANS
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
EXISITING FIRE
HYDRANT
CL R.O.W.
CL R.O.W.
EXISITING TREES
TRANSFORMERS
PER CIVIL
15' - 0"
10' - 0"
12' - 5" 29' - 5"
10' - 0" SETBACK 26' - 3"
15' - 0" SETBACK
SAN
ZEN
O WAY
AMENITY DECK AMENITY DECK
PRIMARY RESIDENTIAL
ENTRY
AMENITY DECK
AMENITY POOL DECKAMENITY COURTYARD
SECONDARY SHARED-USE PATH
397.9'
298.6'
212.3'
NEW TRASH
ENCLOSURE
133.5'
182.6'
40' CORNER VISION TRIANGLE
14' - 0"
SETB
ACK
17' - 10" PROPOSED
TYP.
1' - 4"
8' - 0"
50' - 0"
LOADING SPACE
TRASH STAGING ZONE
36' - 0"
10' - 0"
(6) 3-YARD
TRASH/RECYCLING BINS
SHOWN
SITE PLAN 1/20 SCALE
1" = 20'-0"LU87
1 SITE PLAN
N
SITE PLAN
AMENITY COURTYARD AMENITY POOL DECK
RESIDENTIAL WASTE
STAGING AREA
VISUAL FENCE SCREENING
ON SIDES
TRASH STAGING ZONE
10'-0"
20'-0"
27'-0"
Attachment 5
93 LU SUBMITTAL 05 JULY 05, 2023
SCALE : 1/32” = 1’-0”
DN
ELEV 1 & 2
OFFICE PARKING
ELEV 3
UTILITY
1122 SF
MAINTENANCE
486 SF
ELECTRICAL
TRASH
85 STALLS
RAMP
LOBBY
ELEV 4
RR
OFFICE
BOH
PACKAGE
LOBBY
MAIL
PARLOR
BOILER
5' - 9"
70' - 4" 49' - 7" 70' - 4"
3 BED TOWNHOME 3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
70' - 3" 41' - 0" 48' - 8" 11' - 0" 28' - 0" 48' - 10"
LOADING ZONE
OFFICE PARKING
ENTRY
15' - 0" SETBACK
63' - 0"20' - 0"
3' - 8"
24' - 0" 24' - 0"
RAMP
648 SF
TRANSFORMERS
396 SF
ELECTRICAL
UP
137 SF
WATER
397 SF
FIRE PUMP
20' - 0"
526 SF
ELECTRICAL
123 4 5 67 89 10 11 12 13 14 15 16 17
18 19
20 21
22 23 2425 26 2728 2930 3132 33 3435 36 3738 39 40
41 42
43 44
45 54 53 5251 50 4948 47 46 63 62 6160 59 5857 56 55 65 64 77 78 7980 81 8283 84 85 68 69 7071 72 7374 75 76 66 67 15' - 10"66' - 10"
50' - 7" 47' - 1" 62' - 0"
349' - 11"
ELEC
ELEC
24' - 0" 18' - 0" 18' - 0" 24' - 0" 18' - 0"
22' - 8" 20' - 0"
3' - 7"
14' - 1"
18' - 0"
8' - 6"
RESIDENTIAL PARKING
ENTRY
247' - 9"
SETB
ACK
10' - 0"
GATE
60' - 4"
165' - 8"
3' - 8"
3' - 8"
3' - 9"
94' - 4"
26' - 3"
120' - 7"
79' - 3"
GROUND STORY
MARCH 02, 2023 LU88
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU88
1 GROUND STORY
N
GROUND STORY PLAN
8’ 16’ 32’ 64’
1.89 2.89
Attachment 5
94 LU SUBMITTAL 05 JULY 05, 2023
2ND STORY PLANSCALE : 1/32” = 1’-0”
94 STALLS
RAMP
RAMP
WATER ROOM
STORAGE
3 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME
BIKE PARKING
BIKE PARKING
WATER RM
42 UNITS
84 BIKES
128 BIKES
RESIDENTIAL PARKING
12 UNITS
5' - 9"
ELEV 3ELEV 4
ELEV 1 & 2
70' - 3" 41' - 0" 48' - 8" 11' - 0" 28' - 0" 48' - 10"
ACCESS CONTROL
GATE
18' - 0" 24' - 0" 18' - 0" 18' - 0" 24' - 0" 18' - 0"
24' - 0"
BICYCLE REPAIR
65 SF
8' - 6"
ACCESS CONTROL GATE
26' - 3"
94' - 4"
79' - 3"
46' - 3" 14' - 1"
60' - 4"
70' - 4" 49' - 7" 70' - 4" 97' - 8" 62' - 0"
349' - 11"
61' - 9"103' - 4"
165' - 0"
247' - 9"
120' - 7"
STORAGE
2ND STORY
MARCH 02, 2023 LU89
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU89
1 2ND STORY
N
8’ 16’ 32’ 64’
1.89 2.89
Attachment 5
95 LU SUBMITTAL 05 JULY 05, 2023
3RD STORY PLANSCALE : 1/32” = 1’-0”
DOG WASH
STORAGE
STORAGE
(47) 200 CUFT UNITS
(4) 300 CUFT UNITS
(6) 300 CUFT UNITS
RAMP
UTILITY
(16) 200 CUFT UNITS
TRASH
1 BED F 1 BED A1 BED F1 BED F
TRASH
70' - 4" 49' - 7" 70' - 4" 97' - 8" 62' - 0"
ELEV 3ELEV 4
ELEV 1 & 2
2 BED C- 1 BED A 1 BED A2 BED B2 BED B
1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
STUDIO C
123' - 8"
24' - 6"24' - 0"
349' - 11"
62' - 8"102' - 8"
18' - 0" 24' - 0" 18' - 0" 18' - 0" 18' - 0"24' - 0"
165' - 4"
69' - 7" 41' - 9" 87' - 0" 49' - 7"
8' - 6"
90 STALLS
STORAGE
BIKE PARKING
152 BICYCLE STALLS
PARKING
82' - 1"14' - 0"46' - 3"
247' - 11"
60' - 3"
3RD STORY
MAY 24, 2023 LU90
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU90
1 3RD STORY
N
8’ 16’ 32’ 64’
1.89 2.89
Attachment 5
96 LU SUBMITTAL 05 JULY 05, 2023
4TH STORY PLANSCALE : 1/32” = 1’-0”
1619 SF
FITNESS
STUDIO A+
1448 SF
CLUB HOUSE
STUDIO DSTUDIO D
STUDIO A+
1 BED A 1 BED A 1 BED D
STUDIO A+
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
2 BED B
STUDIO C
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
ELEV 3
ELEV 1 & 2
TRASHTRASH
4TH STORY
MARCH 02, 2023 LU91
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU91
1 4TH STORY
N
1619 SF
FITNESS
STUDIO A+
1448 SF
CLUB HOUSE
69' - 8" 41' - 8" 87' - 0" 47' - 5"
STUDIO DSTUDIO D
STUDIO A+
1 BED A 1 BED A 1 BED D
STUDIO A+
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
2 BED B
STUDIO C
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
245' - 9"
ELEV 3
ELEV 1 & 2
19' - 2"
10' - 0"
10' - 0"
13' - 0"
123' - 8"
62' - 4"36' - 7"65' - 9"
69' - 8" 50' - 4" 69' - 8" 98' - 4"
349' - 8"
90' - 9"
164' - 8"
94' - 10"
14' - 0"46' - 0"
60' - 0"
TRASHTRASH
82' - 1"
61' - 9"
4TH STORY
MARCH 02, 2023 LU91
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU91
1 4TH STORY
N
8’ 16’ 32’ 64’
1.89 2.89
Attachment 5
97 LU SUBMITTAL 05 JULY 05, 2023
SCALE : 1/32” = 1’-0”
2 BED D
STUDIO A
SHAFT TRASH TRASHSHAFT ELEV 3
ELEV 1 & 2
1 BED A
2 BED B
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
1 BED A
5TH STORY
JULY 20, 2022 LU41
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU41
1 5TH STORY
N
69' - 8" 41' - 8" 87' - 0" 47' - 5"
94' - 10"
2 BED D
STUDIO A
SHAFT SHAFT ELEV 3
ELEV 1 & 2
1 BED A
2 BED B
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
1 BED A
10' - 0"
10' - 0"
4' - 6"
13' - 0"
5' - 10"
123' - 8"
69' - 8" 50' - 4" 69' - 8"
349' - 8"
98' - 4" 61' - 9"
90' - 9"
62' - 8"36' - 7"65' - 9"
14' - 0"46' - 0"
60' - 0"
165' - 0"
TRASHTRASH
245' - 9"
82' - 1"
5TH STORY
MARCH 02, 2023 LU92
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU92
1 5TH STORY
N
5TH STORY PLAN
8’ 16’ 32’ 64’
1.89 2.89
Attachment 5
98 LU SUBMITTAL 05 JULY 05, 2023
SCALE : 1/32” = 1’-0”
SHAFT TRASH TRASHSHAFT ELEV 3
ELEV 1 & 2
2 BED D
STUDIO A
1 BED A
2 BED F
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED E
2 BED A
2 BED A 2 BED A
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
1 BED A
2 BED G
STUDIO D
2 BED A
6TH STORY
JULY 20, 2022 LU42
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU42
1 6TH STORY
N
69' - 8" 41' - 8" 87' - 0" 47' - 5"
94' - 10"
SHAFT SHAFT ELEV 3
ELEV 1 & 2
2 BED D
STUDIO A
1 BED A
2 BED F
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED E
2 BED A
2 BED A 2 BED A
2 BED C
1 BED B
1 BED A 1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED C 1 BED C+
1 BED A
2 BED G
STUDIO D
2 BED A
10' - 0"
10' - 0"
90' - 9"
65' - 9"
165' - 0"
69' - 8" 50' - 4" 69' - 8" 98' - 3" 61' - 9"
349' - 8"
TRASHTRASH
123' - 8"
14' - 0"46' - 0"
60' - 0"
245' - 9"
82' - 1"
6TH STORY
MARCH 02, 2023 LU93
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU93
1 6TH STORY
N
6TH STORY PLAN
8’ 16’ 32’ 64’
1.89 2.89
Attachment 5
99 LU SUBMITTAL 05 JULY 05, 2023
SHAFT TRASH TRASHSHAFT ELEV 3
ELEV 1 & 2
2 BED D
STUDIO A
1 BED A
2 BED B
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A 1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
1 BED A
2 BED G
STUDIO D
2 BED E
7TH STORY
JULY 20, 2022 LU43
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU43
1 7TH STORY
N
94' - 10"
SHAFT SHAFT ELEV 3
ELEV 1 & 2
2 BED D
STUDIO A
1 BED A
2 BED B
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A
2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A 1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
1 BED A
2 BED G
STUDIO D
2 BED E
10' - 0"
10' - 0"
4' - 5"
90' - 9"
246' - 9"
121' - 11"
69' - 8" 41' - 8" 87' - 0" 48' - 5"
5' - 6"
TRASHTRASH
14' - 5"46' - 0"
60' - 5"
69' - 8" 50' - 4" 69' - 8" 98' - 3" 61' - 9"
349' - 8"
36' - 7"65' - 9"
165' - 0"
81' - 11"
62' - 8"
7TH STORY
MARCH 02, 2023 LU94
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU94
1 7TH STORY
N
7TH STORY PLAN
1.89 2.89
Attachment 5
100
LU SUBMITTAL 05 JULY 05, 2023
CLUB HOUSE
SHAFT TRASH TRASHSHAFT ELEV 3
ELEV 1 & 2
STUDIO A
1 BED A
2 BED B
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A
2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED A
STUDIO D
2 BED E
1 BED A
8TH STORY
JULY 20, 2022 LU44
170 SAN ZENO WAY
SUNNYVALE, CA 94086
SCALE : 1/32” = 1’-0”
CLUB HOUSE
94' - 0"
68' - 6" 43' - 1" 85' - 6" 46' - 6"
243' - 6"
ELEV 1 & 2
STUDIO A
1 BED A
2 BED B
STUDIO C
STUDIO D
STUDIO D
1 BED A
1 BED A
1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B
1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED A
STUDIO D
2 BED E
68' - 3" 52' - 1" 68' - 0" 112' - 10" 36' - 9"
9' - 4"10' - 9"
1 BED A
9' - 4"
10' - 9"
90' - 9"
740 SF
75' - 4"9' - 0"79' - 0"
TRASHTRASH
163' - 4"
12' - 10"
337' - 10"
35' - 7" 18' - 2"
53' - 9"
121' - 11"
81' - 0"
8TH STORY
MARCH 02, 2023 LU95
170 SAN ZENO WAY
SUNNYVALE, CA 94086
8TH STORY PLAN
8’ 16’ 32’ 64’
1.89 2.89
Attachment 5
101
LU SUBMITTAL 05 JULY 05, 2023
163' - 8"
94' - 0"
68' - 8" 43' - 0" 85' - 9" 46' - 4"
68' - 5" 52' - 1" 68' - 0" 112' - 10" 36' - 9"
20' - 1"
243' - 8"
35' - 7" 18' - 2"
53' - 9"
ELEV /
STAIR
OVERRUN
STAIR STAIR
ELEV
RIDGE
RIDGE
RIDGE
HATCH
HATCH
RIDGE
STAIR
RIDGE
RIDGE
RIDGE
RIDGE
RIDGE
RIDGE
RIDGE
RIDGE
90' - 9"
PV PANELS
PV PANELS
PV PANELSPV PANELS
PV PANELS
PV PANELS
PV PANELS
PV PANELS
PV PANELS PV PANELS
PV PANELS PV PANELS
PV PANELS
PV PANELS PV PANELS
MECHANICAL UNITS MECHANICAL UNITS MECHANICAL UNITS MECHANICAL UNITS
MECHANICAL UNITSMECHANICAL UNITS
MECHANICAL UNITS MECHANICAL UNITS
MECHANICAL UNITS
EXHAUST FAN (4FT)
GARAGE EXHAUST
FAN (9FT)
SUPPLY FAN (6FT)
SUPPLY FAN (6FT)
EXHAUST FAN (4FT)
EXHAUST FAN, (4FT)
338' - 1"
77' - 8" 10' - 4" 75' - 8"
5' - 10"
12' - 10" 10' - 7"
20' - 3"
SUPPLY FAN (6FT)
EXHAUST FAN (4FT)
T.O. PARAPET
(2.75FT) TYP.
T.O. PARAPET
(3.5FT) TYP.
UNIT HEAT PUMPS, TYP (2.5FT)
LOUVER SCREEN
(TO MATCH UNIT HEIGHT)
81' - 4"
122' - 11"
ROOF PLAN
MAY 24, 2023 LU96
170 SAN ZENO WAY
SUNNYVALE, CA 94086
SCALE : 1/32” = 1’-0”
SCALE 1/32" = 1'-0"
0 32
KIFER DEVELOPME
PLAN - 4TH LEVEL
ACLA
10.12.2022 ROOF PLAN
8’ 16’ 32’ 64’
1.89 2.89
Attachment 5
102
LU SUBMITTAL 05 JULY 05, 2023
GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
3' - 6"13' - 0"10' - 3"10' - 3"10' - 3"10' - 3"11' - 2"10' - 6"9' - 4" 1' - 2"
88' - 6"
GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
1' - 2" 9' - 4" 10' - 6" 11' - 2" 10' - 3" 10' - 3" 10' - 3" 10' - 3" 13' - 0" 3' - 6" 88' - 6"
BUILDING ELEVATIONS
AUGUST 21, 2022 LU61
170 SAN ZENO WAY
SUNNYVALE, CA 94086
GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
3' - 6"13' - 0"10' - 3"10' - 3"10' - 3"10' - 3"11' - 2"10' - 6"9' - 4"1' - 2" 88' - 6"
GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
88' - 6"
3' - 6"13' - 0"10' - 3"10' - 3"10' - 3"10' - 3"11' - 2"10' - 6"9' - 4"1' - 2"
BUILDING ELEVATIONS
AUGUST 21, 2022 LU60
170 SAN ZENO WAY
SUNNYVALE, CA 94086
BUILDING ELEVATIONS
NORTH ELEVATION
SCALE : 1/32” = 1’-0”
SCALE : 1/32” = 1’-0”
EAST ELEVATION
8’ 16’ 32’ 64’
METAL CANOPIES
SPANDREL PANEL
METAL PANEL
TEXTURED BRICK CLADDING 1 SPANDREL PANEL
STUCCO 2 METAL CANOPY
CEMENT PANEL 3 CEMENT PANEL 1
1.89 METAL PANEL
VINYL WINDOW
BRICK CLADDING 1
GLASS GUARDRAIL
METAL SCREEN
GREENWALL
CEMENT PANEL 2
STEEL RAILING
STOREFRONT
BRICK CLADDING 2
2.89 Attachment 5
103
LU SUBMITTAL 05 JULY 05, 2023
GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
88' - 6"
3' - 6"13' - 0"10' - 3"10' - 3"10' - 3"10' - 3"11' - 2"10' - 6"9' - 4"1' - 2"
BUILDING ELEVATIONS
AUGUST 21, 2022 LU60
170 SAN ZENO WAY
SUNNYVALE, CA 94086
METAL SCREEN
GREENWALL
42 INCH PARAPET
1.89 GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
3' - 6"13' - 0"10' - 3"10' - 3"10' - 3"10' - 3"11' - 2"10' - 6"9' - 4" 1' - 2"
88' - 6"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
" 13' - 0" 3' - 6"
CEMENT PANEL 1
BUILDING ELEVATIONS
SCALE : 1/32” = 1’-0”
SOUTH ELEVATION
WEST ELEVATION
SCALE : 1/32” = 1’-0”
8’ 16’ 32’ 64’
ROLL-UP DOOR
2.89 CEMENT PANEL 1
Attachment 5
104
LU SUBMITTAL 05 JULY 05, 2023
SCALE : 1/32” = 1’-0”
BUILDING SECTION N-S
BUILDING SECTIONS
1. 2.
SCALE : 1/32” = 1’-0”
BUILDING SECTION E-W
8’ 16’ 32’ 64’ Attachment 5
105
LU SUBMITTAL 05 JULY 05, 2023
ELEVATION DIAGRA
AUGUST 21, 2022 LU1
170 SAN ZENO WAY
SUNNYVALE, CA 94086
MATERIAL PALETTE - NORTH
BRICK CLADDING 2
BRICK CLADDING 2
BRICK CLADDING 1
BRICK CLADDING 1
CEMENT PANEL 1CEMENT PANEL 2STUCCO 2
STUCCO 2METAL CANOPIES METAL CANOPIES
CEMENT PANEL 3 GLASS RAILING
WOOD
STOREFRONT SPANDREL PANEL
STEEL RAILING
METAL PANEL
Attachment 5
106
LU SUBMITTAL 05 JULY 05, 2023
ELEVATION DIAGRAMS
AUGUST 21, 2022 LU20
170 SAN ZENO WAY
SUNNYVALE, CA 94086
STUCCO 2
MATERIAL PALETTE - SOUTH
* WIRE CABLE FOR
* SEE METAL SCREEN GREENWALL FOR ADDITIONAL DETAILS
* WIRE MESH * SEMI-TRANSLUCENT
BRICK CLADDING 1
CLIMBING PLANTSON STEEL FRAME WOVEN WIRE MESH
CEMENT PANEL 3 CEMENT PANEL 2SPANDREL PANEL STEEL RAILINGGLASS RAILINGCEMENT PANEL 1 BRICK CLADDING 1*SPANDREL PANEL
Attachment 5
107
LU SUBMITTAL 05 JULY 05, 2023
MATERIAL BOARD
METAL PANEL - BOX RIB
MATTE BLACK
STUCCO 2- SMOOTH
COLOR TERRACOTTA
SPANDREL PANEL
CHARCOAL
STOREFRONT
BLACK
WINDOWS
BLACK EXTERIOR
CEMENT PANEL
TERRACOTTA
BRICK CLADDING 1
ARCTIC WHITE
CEMENT PANEL
CHARCOAL
BRICK CLADDING 2
CHARCOAL
CEMENT PANEL
COLOR TO MATCH ARCTIC WHITE
UPPER STORIES
LOWER STORIES
Attachment 5
108
LU SUBMITTAL 05 JULY 05, 2023
BEDROOM
LIVING
DINING
KITCHEN
BATH
BALCONY
W/D
CLOSET
24' - 10" 5' - 0"
30' - 9"
10' - 5" 12' - 11"
24' - 2"
BEDROOM 1
BATH 1
STORAGE
BEDROOM 2
LIVING
DINING
KITCHEN
BALCONY
BATH 2
CLOSET
5' - 0"24' - 11"
30' - 8"
10' - 6" 24' - 3"
35' - 7"
5' - 10"
7' - 10"
CLOSET
W/D
BATH
KITCHEN
LIVING
30' - 9"
16' - 8"
DINING
BEDROOM
W/D
BALCONY
UNITS
MARCH 02, 2023 LU103
170 SAN ZENO WAY
SUNNYVALE, CA 94086
UNIT LAYOUT EXAMPLES
STUDIO UNIT 1 BEDROOM UNIT 2 BEDROOM UNIT
SCALE : 1/8” = 1’-0” SCALE : 1/8” = 1’-0” SCALE : 1/8” = 1’-0” Attachment 5
109
LU SUBMITTAL 05 JULY 05, 2023
W
M
W
M
W
M
W
M
TREE #696
TREE #706
TREE #696
TREE #706
RAMP
RAMP
OVERALL SITE PARKING
MARCH 02, 2023 LU104
170 SAN ZENO WAY
SUNNYVALE, CA 94086
OVERALL SITE PARKING
SEE GROUND STORY PARKING SHEET FOR
PARKING IN PROPOSED BUILDING
16 CAR SHARE SPACES (5%) OF NONRESIDENTIAL AND MIXED-USE PARKING 305 STALLS, TO BE IDENTIFIED WITH MARKINGS, SIGNS AS
NECESSARY
EXISTING EV PARKING CHARGING STATIONS, TO REMAIN
15 CLASS II OFFICE BICYCLE PARKING SPACES
29 TOTAL CLASS I OFFICE BICYCLE PARKING SPACES
OFFICE TENANT CURCULATION ROUTE
148 EXISTING STALLS TO REMAIN ON OFFICE PARCEL
Attachment 5
110
LU SUBMITTAL 05 JULY 05, 2023
SCALE : 1/32” = 1’-0”
DN
ELEV 1 & 2
OFFICE PARKING
ELEV 3
UTILITY
MAINTENANCE
ELECTRICAL
TRASH
85 STALLS
RAMP
LOBBY
ELEV 4
RR
OFFICE
BOH
PACKAGE
LOBBY
MAIL
PARLOR
BOILER
TRASH
3 BED TOWNHOME 3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
OFFICE PARKING
ENTRY
RAMP
TRANSFORMERS ELECTRICAL
UP
WATERFIRE PUMP ELECTRICAL
123 4 5 67 89 10 11 12 13 14 15 16 17
18 19
20 21
22 23 2425 26 2728 2930 3132 33 3435 36 3738 39 40
41 42
43 44
45 54 53 5251 50 4948 47 46 63 62 6160 59 5857 56 55 65 64 77 78 7980 81 8283 84 85 68 69 7071 72 7374 75 76 66 67 ELEC
ELEC
24' - 0"18' - 0"8' - 6"
18' - 0" 24' - 0"8' - 6"
24' - 0"
24' - 0"
RESIDENTIAL PARKING
ENTRY
GROUND STORY PARKING
MARCH 02, 2023 LU105
170 SAN ZENO WAY
SUNNYVALE, CA 94086
GROUND STORY PARKING
8’ 16’ 32’ 64’ LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1 LEVEL 2 LEVEL 2
LEVEL 2LEVEL 2
LEVEL 2
LEVEL 2
LEVEL 2
LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2
LEVEL 2 LEVEL 2LEVEL 2
LEVEL 2
LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2LEVEL 2
LEVEL 2
LEVEL 2 LEVEL 2
CLASS 1 BICYCLE PARKING USER ROUTE35% (30) LEVEL 2 - EVCS 65% (55) LEVEL 1 - EV READY SPACE
REACH CODE REQUIREMENTS FOR OFFICE PARKING EV PARKING SPACES, SMC TITLE 16, REACH CODES 85 SHARED PARKING SPACES AT GROUND STORY
*SEE OVERALL PARKING SHEET 109 FOR EXISTING ONSITE PARKING SPACES
OFFICE TENANT CURCULATION ROUTE
OFFICE TENANT CURCULATION ROUTE
OFFICE PARKING / SHARED PARKING
Attachment 5
111
LU SUBMITTAL 05 JULY 05, 2023
94 STALLS
RAMP
RAMP
WATER ROOM
STORAGE
3 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME
BIKE PARKING
BIKE PARKING
WATER RM
(39) 200 CUFT UNITS
(3) 300 CUFT UNITS
79 BIKES
126 BIKES
RESIDENTIAL PARKING
11 200 CUFT UNITS
1 300 CUFT UNITS
ELEV 3ELEV 4
ELEV 1 & 2
ACCESS CONTROL
GATE
BICYCLE REPAIR
65 SF
12 345 67 8 13 14 15 16 17 18 19 21 20 23
25 26
27 29 30 3132 3334 3536 37 3839 40 4142 43 44
45 54
53 52
6362 61 6059 58 575655 65 64
77 78 798081 8283 84 85
74 75
9 10 11 12 22
24 46
47 48
49 50
51 66 67 68 69 70 71 72 73
86 878889 90 9192
28 93
9' - 0"
18' - 0"
8' - 6"
24' - 0"18' - 0"
24' - 0" 24' - 0"
24' - 0"
76 94
ACCESS CONTROL
GATE
STORAGE
2ND STORY PARKING
MARCH 02, 2023 LU106
170 SAN ZENO WAY
SUNNYVALE, CA 94086
SCALE : 1/32” = 1’-0”
2ND STORY PARKING
8’ 16’ 32’ 64’ CALGREEN EV SPACES (9X18)
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2
LEVEL 2LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2
LEVEL 2LEVEL 2
LEVEL 2LEVEL 2
LEVEL 2LEVEL 2LEVEL 2
LEVEL 2 LEVEL 2
LEVEL 2LEVEL 2 LEVEL 2LEVEL 2
LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2
LEVEL 1 LEVEL 1
LEVEL2 LEVEL 2
CLASS I
CLASS I
CLASS I
REPAIR
REPAIR
CLASS 1 BICYCLE PARKING USER ROUTE
35% (25) LEVEL 2 - EVCS 35% (8) LEVEL 2 - EVCS
205 CLASS I BICYCLE PARKING SPACES
65 SF BICYCLE REPAIR STATION
65% (46) LEVEL 1 - EV READY SPACE 65% (15) LEVEL 1 - EV READY SPACE REACH CODE REQUIREMENTS FOR EV PARKING SPACES, SMC TITLE 16, REACH CODES
OFFICE PARKING / SHARED PARKING RESIDENTIAL PARKING
71 SHARED PARKING SPACES AT SECOND STORY 23 RESIDENTIAL PARKING Attachment 5
112
LU SUBMITTAL 05 JULY 05, 2023
3RD STORY PARKING
DOG WASH
90 STALLS
RAMP
UTILITY
TRASH
1 BED F 1 BED A1 BED F1 BED F
ELEV 3ELEV 4
ELEV 1 & 2
2 BED C- 1 BED A 1 BED A2 BED B2 BED B
1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
STUDIO C
1 2 3 4 56 7 8 13 14 15 16 17 18 19
21 20
23 25
26 27
3032 3334 35 3637 38 394042
43 44
45 54 53 52 63 62 6160 59 5857 56 55 65 64
77 7879 808182 83 8485 7576
9 10 11 12
22 24
46 47
48 49
50 66 67 68 69 70 71 72
86 8788
29 28
3141
51 73
89 9' - 0" 8' - 6"
24' - 0"18' - 0"24' - 0"
18' - 0" 24' - 0"
24' - 6"
74 90
ACCESS CONTROL GATE
TRASH
(6) 300 CUFT UNITS
STORAGE
STORAGE
(16) 200 CUFT UNITS
STORAGE
(16) 200 CUFT UNITS
(46) 200 CUFT UNITS
(4) 300 CUFT UNITS
STORAGE
BIKE PARKING
152 BIKE PARKING
3RD STORY PARKING
MARCH 02, 2023 LU107
170 SAN ZENO WAY
SUNNYVALE, CA 94086
SCALE : 1/32” = 1’-0”
8’ 16’ 32’ 64’ CALGREEN EV SPACES (9X18)
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 RC LEVEL 1 RCLEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1 RC LEVEL 1 RCLEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 RC LEVEL 1 RC
LEVEL 1LEVEL 1LEVEL 1LEVEL 1 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2LEVEL 2LEVEL 2LEVEL 2 LEVEL 2LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 1
LEVEL 2 35% (32) LEVEL 2 - EVCS
65% (58) LEVEL 1 - EV READY SPACE
LEVEL 2LEVEL 2 LEVEL 2LEVEL 2LEVEL 2LEVEL 2LEVEL 2 LEVEL 2LEVEL 2
CLASS I
REACH CODE REQUIREMENTS FOR EV PARKING SPACES, SMC TITLE 16, REACH CODES 152 CLASS I BICYCLE PARKING SPACES
Attachment 5
113
LU SUBMITTAL 05 JULY 05, 2023
METAL SCREEN GREENWALL
LINE OF SIGHT
6’-0”
Attachment 5
114
LU SUBMITTAL 05 JULY 05, 2023
METAL SCREEN GREENWALL
WIRE MESH BETWEEN PILASTERS BRICK ON STEEL FRAME
WIRE CABLE FOR CLIMBING PLANTS
SEMI-TRANSLUCENT WOVEN WIRE MESH TO PROVIDE
DAYLIGHT WHILE OBSCURING VIEWS INTO THE PARKING LEVEL
Attachment 5
115
LU SUBMITTAL 05 JULY 05, 2023
ARCHITECTURAL & LANDSCAPE LIGHTING PLAN
LU SUBMITTAL 02 AUGUST 5TH, 202
DRAFT
LANDSCAPE SITE P
1/32” =
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8 " x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
10.06. 2022
DATE# REVISION LIST
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L801
1/16" = 1'-0"
LIGHTING PLAN
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
LIGHTING
LU SUBMITTAL 02 AUGUST 5TH, 2022 37
DRAFT
LANDSCAPE SITE PLAN
1/32” = 1’-0”
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET TITL
ISSUES
PROJECT N
DATE:
SCALE:
KEYPLAN
#
LIGHT
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO
SHEET TI
ISSUES
PROJECT
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
#
LIGH
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
10.06. 2022
DATE# REVISION LIST
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L801
1/16" = 1'-0"
LIGHTING PLAN
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
LIGHTING PLAN
BEGA WALL LUMINAIRE
NARROW BEAM DOWNWARD
BEGA DOWNLIGHT
WALL SCONCE LIGHTS RECESSED LIGHT
Attachment 5
116
LU SUBMITTAL 05 JULY 05, 2023
ON-SITE LIGHTING SITE PLAN
Attachment 5
117
LU SUBMITTAL 05 JULY 05, 2023
ON-SITE PHOTOMETRIC PLAN
Attachment 5
118
LU SUBMITTAL 05 JULY 05, 2023
EV
EV
EV
AL
56 BIKES
DN
ELEV
OFFICE PARKING
ELEV
BIKE PARKING
UTILITY
MAINTENANCE
ELECTRICAL
TRASH
165' - 0"
85 STALLS
RAMP
RAMP
59'
58'
60'
58'
LOBBY
ELEV
ELECTRICAL TRANSFORMER
RR
OFFICE
BOH
PACKAGE
LOBBY
MAIL
PARLOR
FIRE CONTROL
BOILER
TOOLS
20' - 0"
5' - 6"
18' - 0" 24' - 0" 18' - 0"
1' - 6"
18' - 0" 24' - 0" 18' - 0"
24' - 0"
24' - 0"
57' - 0"
17' - 0" 20' - 0" 20' - 0"
69' - 6" 50' - 6" 69' - 6" 50' - 6" 109' - 6"
349' - 6"
3335 303132 28293637
8385 808182
4644 494847
41 40
777879
525150
747576
555453
26 585756 616059 6362
27 52 11 141312
717273 686970 6667
2425 23
42 10
43 17
18 1 674 9
22 21 20
16 19
39 38
84 45
34 15
64 65
3 TRASH
8 3 BED TOWNHOME 3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
160' - 0" 11' - 0" 77' - 6"
2' - 6"
2' - 6"
5' - 6"
9' -
6"
3' - 6"
UP
LOADING ZONE
OFFICE PARKING
ENTRY
RESIDENTIAL PARKING
ENTRY
10' - 0" SETBACK
10' - 0" SETBACK
22' - 0" SETBACK
10' - 0" SETBACK
15' - 0" SETBACK
120' - 0"
62' - 6"20' - 0"82' - 6"
248' - 0"
78 ' - 6"
GROUND STORY
MARCH 18, 2022 LU37
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU37
1 GROUND STORY
N
DAVIS DOOR VERTICAL LIFT GATE
Combines security and reliability in high-traffic environments. The gate’s aluminum panel can be a visual upgrade to any multi-family or commercial building. Designed for over 1 million cycle usage with a 5 year warranty.
Operator
Standard - Heavy duty gate operator with an opening speed of 12-inch per second.
Upgrade - Direct drive operator with an opening speed of 24-inch per second.
Safety Features
72-inch tall monitored light curtains revese the door when an oibject is detected.
Monitored contact sensing edge on the bottom of the gate.
Laser base curtain securely protects the outside of the door
2.2 ALUMINUM VERTICAL LIFT GATE
A. Aluminum Vertical Lift Gate: Davis Door DDS-WCVLG Units shall have the following characteristics:
1. Door Assembly: Fabricate vertical lift panels consisting of welded aluminum tube frame with overlay of ¾” x .125 expanded aluminum sheeting or .050 solid aluminum sheeting. a. Aluminum tube: ASTM B 221 6063-T52
b. Flattened expanded aluminum sheet, 5005-H34, ¾” x .125 or .050 solid aluminum sheeting c. Welded construction frame, mechanically attached expanded or solid sheet d. Mill finish on aluminum
e. Steel shapes, plates and bars: ASTM A 36
2. Counterbalance system: Counterbalance door by means of roller chains, sprockets, and steel counter- weights traveling in one common galvanized steel counterweight tower. This system uses heavy duty , 4 bolt
cast flange bearings and solid keyed stress proof shafts.
3. Steel structural towers: 14 gauge hot dipped galvanized ASTM A924
4. Bottom of door: Manufacturers standard design
a. Miller Edge, 2 wire, reversing electric sensing edge, bottom seal combination
5. Finish and Color:
a.
Aluminum to be natural mill finished
b. Powder Coating Finish: Color as selected by Architect from manufacturer’s standard colors.
6. Windload Design: Provide to meet the Design/Performance requirements specified.
7. Locking:
a. Panel locks to prevent lifting and bottom arrester/lifting catches.
8. Track: extruded aluminum to minimize contact with continuous UHMW guide strips, eliminating metal to metal contact, reducing noise and vibration. They will allow the door to breakaway in the event of impact with a vehicle.
9. Electric Motor Operation:
a. Industrial duty All-O-Matic SL100DC Motor System
- Opening speed: 12” per second with soft start and stop b. Micanan Titan Series Operator
- Opening speed: 24” per second with soft start and stop VIEW 2
IS SHOWN ABOVE
FASCIA PANEL
GATE PANEL
FLOOR
100"
(8' 4")
OPENING
HEIGHT
30"
(2' 6")
TBD
DAVIS DOOR
2021 Sou
Sea
9 1-800
FAX: 20
EMAIL: info@
280649
JOB #
HYDE SQUAR
JOB NAME
OWNER / PROPER
DAVIS DOOR SER
ARCHITECT
¾” : 1'- 0"
SCALE
JENSEN DAV
ORDERED BY
KEVIN PURDI
DRAWN BY
REVISED 5 / 1
DATE
HYDE SQUAR
GATE REV
COMPUTER FILE
DRAWING # 3
COPYRIGHT 2022 THE INFORMATION PROVIDED ON THIS DOCUMENT IS THE PROPERTY OF DAVIS DOOR SERVICE, INC., ANY REPRODUCTION OR USE OF THIS DESIGN OR CONCEPT WITHOUT WRITTEN PERMISSION IS PROHIBITED.
INSIDE LOOKING
OUT
VERTIC
GA
271 ¼”
(22' 7 ¼”)
OPENING WIDTH
293”
(24' 5”)
TOTAL WIDTH
17 ¾”4"
ALL DIMENSIONS WILL BE FIELD VERIFIED
PRIOR TO CONSTRUCTION
130"
(10' 10")
TOTAL
HEIGHT
130"
(10' 10")
TOTAL
HEIGHT
COLUMN
WALL
CEILING / INSULATION
THE BLUE DOTTED LINES REPRESENT
THE LOCATIONS OF THE #40 NP
LIFTING CHAINS
TYP.
NOTE : THE GREEN DOTTED LINE
REPRESENTS THE LOCATION OF THE GATE
PANELS IN THE OPEN POSITION
TYP.
SENSING
EDGE
NOTE : ¼” X 1" GR8 HEX
FLANGE BOLTS YELLOW
ZINC (FFS324) WILL BE
USED TO ATTACH THE
WEIGHT BOX COVERS TO
THE TOWER
TYP.
ALUMINUM WEIGHT BOX
COVER
(SAME BOTH SIDES)
TYP.
ALUMINUM
FLASHING
TYP.
100"
(8' 4")
OPENING
HEIGHT
DOOR SAFETY LOCK
(HVD470)
6 – ¼” X 1" KINNEAR
SCREWS PER LOCK
(FFS435)
TYP.
17 ¾”4"
WEIGHT
BOX
VIEW 1
IS SHOWN TO
THE RIGHT
271 ¼”
(22' 7 ¼”)
OPENING WIDTH
PANELFASCIA
GATE PANEL
GATE PANEL
GATE PANEL
GATE PANEL
GATE PANEL
DDS ALUMINUM
VERTICAL LIFT
GATE TRACK
TYP.
½” UHMW
GUIDE
TYP.
INSIDE
FACE
1 ½”
TYP.
25 ½”
3" X 4" X ¼”
ALUMINUM ANGLE
BRACKET
TYP.
ALUMINUM
FLASHING / COVER
WALL
COLUMN
EXISTING 6" X 6"
STEEL TUBE
TYP.
ALUMINUM
FLASHING
TYP.
6"
12"
4"
10"
INSIDE
FACE
2”
OVERLAP
TYP.
DOOR SAFETY LOCK
(HVD470)
6 – ¼” X 1" KINNEAR
SCREWS PER LOCK
(FFS435)
TYP.
CEILING / INSULATION
GATE PANEL
GATE PANEL
GATE PANEL
GATE PANEL
WALL
130"
(10' 10")
TOTAL
HEIGHT
EXISTING STEEL TUBE
NOTES:
__ 1 – BEA FALCON XL MOTION SENSOR
(OSE516)
__ 1 – RH NON-MONITORED ME-123
MILLER EDGE WITH A CA3 ALUMINUM
RETAINER AT 22' 6 ¼”
__ 1 – MULTI-CODE REVERSE EDGE
TRANSMITTER (ORC340)
__ 1 – MULTI-CODE RECEIVER 1099-50
(ORC315)
__ 1 – 3 BUTTON STATION 3-PBS
(OPB012)
1 2
FASCIA
PANEL
GATE
PANEL #5
GATE
PANEL #4
GATE
PANEL #3
GATE
PANEL #2
GATE
PANEL #1
NOTES:
* GATE WILL BE MIL
INCLUDE THE FOLLO
__ 1 – MICANAN TITA
OPERATOR (208 VAC
__ 1 – MICANAN TITA
230V / 460V PRIMAR
__ 1 – SET OF MILLE
MONITORED LIGHT
__ 1 – PR. LIGHT CU
BRACKETS (OPH178
__ 1 – BEA LZR-i30 L
(OSE525)
__ 1 – TRC / MEAN W
DIN RAIL POWER SU
MICANAN TITAN
SERIES OPERATOR
(208 VAC 1 PH)
TYP.
MICANAN TITAN
SERIES OPERATOR
(208 VAC 1 PH)
TYP.
*DIMENSIONS FOR REFERENCE ONLY. COORDINATE OPENINGS WITH ACTUAL PROJECT PARAMETERS
GARAGE DOOR DESIGN
Attachment 5
119
LU SUBMITTAL 05 JULY 05, 2023
BICYCLE RACKS
Attachment 5
120
LU SUBMITTAL 05 JULY 05, 2023
Benefits Of Cal Stor-N-Lock Storage Lockers
Security
Cal Stor-N-Lock storage lockers are the ideal solution to securing and organizing your valuable possessions. Wire mesh provides security, while permitting proper lighting and ventilation.
Simplicity
Cal Stor-N-Lock lockers can be erected easily with simple hand tools, along with our installation manual. Modular design makes future relocation or reconfiguration fast and efficient.
Cal Wire
Wire Mesh Products Since 1948
Cal Stor-N-Lock
Welded Wire Storage Lockers
Applications:
Personnel Storage Military Bases
Gym Equipment Retirement Communities
Post Offices Apartment Facilities
Parking Garages Schools
Colocation Areas Any Of Y our Ideas!
Also Available:
Special Finishes Custom Sizes
Ceiling Panels Headerless Gates
Double Doors Custom Colors
Handrail Infill Panels Window Guards
LOCKABLE STORAGE
UNIT TYPE 1 LOCKABLE STORAGE:
3’ x 8’ x 9’ = 216 CUFT - PRODUCT REFERENCED
IN-UNIT TYPE 1 STORAGE IN STUDIO/1BED UNITS
UNIT TYPE 2 LOCKABLE STORAGE:
4’-6” x 8’ x 9’ = 324 CUFT - PRODUCT REFERENCED
IN-UNIT TYPE 2 STORAGE IN 2BED & 3 BED UNITS
COUNT COUNT200 CUFT STORAGE UNITS
STORAGE UNIT SUMMARY
300 CUFT STORAGE UNITS
112
43 59
14 UNIT TYPE 1 & 2 LOCKABLE STORAGEUNIT TYPE 1 LOCKABLE STORAGE UNIT TYPE 2 LOCKABLE STORAGE
UNIT QTY
70 70
73 73
155 155
155
155STUDIOS & 1 BEDROOMS:
2 & 3 BEDROOMS:
200 CUFT PER STUDIO & 1 BEDROOM UNITS
TOTAL 200 CUFT MINIMUM PER STUDIO & 1 BEDROOM UNITS
300 CUFT PER UNIT FOR ALL OTHERS
TOTAL 300 CUFT PER UNIT FOR ALL OTHERS
REQUIRED STORAGE:STORAGE SIZE REQUIREMENTSUNIT TYPES PROVIDED STORAGE:
BEDRO
OM 1
BATH 1
STORAGE
BEDROOM
2 LIVING
DINING
KITCHEN
BALCO
NY
BATH 2
CLOSET
10' - 6" 24' - 4"
35' - 7"
6' - 4"
8' - 0"CLOSET
W/D
IN-UNIT STORAGE MINIMUM DIMENSIONS
3’ - 0”
9FT HEIGHT, TYP.
8’ - 0”
Attachment 5
121
LU SUBMITTAL 05 JULY 05, 2023
1" = 60'-0"LU116
1 GROUND STORY STORAGE UNIT KEY
1" = 60'-0"LU116
2 3RD STORY STORAGE UNIT KEY
1" = 60'-0"LU116
3 4TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
4 5TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
5 8TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
6 6TH & 7TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
1 GROUND STORY STORAGE UNIT KEY
1" = 60'-0"LU116
2 3RD STORY STORAGE UNIT KEY
1" = 60'-0"LU116
4 5TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
6 6TH & 7TH STORY STORAGE UNIT KEY
STORAGE IN UNIT PLANS
1" = 60'-0"LU116
1 GROUND STORY STORAGE UNIT KEY
1" = 60'-0"LU116
2 3RD STORY STORAGE UNIT KEY
1" = 60'-0"LU116
3 4TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
4 5TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
5 8TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
6 6TH & 7TH STORY STORAGE UNIT KEY
1" = 60'-0"16
GROUND STORY STORAGE UNIT KEY
1" = 60'-0"16
3RD STORY STORAGE UNIT KEY
1" = 60'-0"16
4TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
4 5TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
5 8TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
6 6TH & 7TH STORY STORAGE UNIT KEY
1" = 60'-0"16
GROUND STORY STORAGE UNIT KEY
1" = 60'-0"16
3RD STORY STORAGE UNIT KEY
1" = 60'-0"LU116
4 5TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
6 6TH & 7TH STORY STORAGE UNIT KEY
STORAGE IN UNIT PLANS
1" = 60'-0"16
GROUND STORY STORAGE UNIT KEY
1" = 60'-0"16
3RD STORY STORAGE UNIT KEY
1" = 60'-0"16
4TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
4 5TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
5 8TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
6 6TH & 7TH STORY STORAGE UNIT KEY
6TH & 7TH STORY
5TH STORYGROUND STORY
3RD STORY
TOTAL IN UNIT STORAGE COUNT
4TH STORY 8TH STORY
2 BED+ QTY: 11
2 BED+ QTY: 92 BED+ QTY: 5
2 BED+ QTY: 4
2 BED+ QTY: 9 2 BED+ QTY: 10
STUDIO/1 BED QTY: 9
STUDIO/1 BED QTY: 9STUDIO/1 BED QTY: 0
STUDIO/1 BED QTY: 0
STUDIO/1 BED QTY: 9 STUDIO/1 BED QTY: 7
IN-UNIT STORAGE STORY PLANS
IN-UNIT 300CUFT MIN STORAGE IN 2BED & 3 BED UNITS
TOTAL UNITS WITH IN-UNIT STORAGE
59 102
IN-UNIT 200 CUFT MIN STORAGE IN STUDIO/1BED UNITS43
Attachment 5
122
LU SUBMITTAL 05 JULY 05, 2023
DWREF
W/D
W/D
DW
W/D
DW
W/D
W/D
W/D
W/D
W/D
UP W/D
DNSTORAGE
8' - 0"
3' - 11"
STORAGE
6' - 0"
8' - 0"
STORAGE
6' - 5"
8' - 7"
STORAGE
12' - 5"
4' - 0"
STORAGE
4' - 0"
4' - 7"
3' - 0"
5' - 0"
3' - 1"
9' - 3"
5' - 4"
4' - 3"
STORAGE
STORAGE
5' - 8 1/2"8' - 1"
STORAGE
6' - 5"
9' - 8"
STORAGE UNIT KEY
MARCH 02, 2023 LU117
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/8" = 1'-0"LU117
2 UNIT - 1 BED B 282 CUFT
1/8" = 1'-0"LU117
3 UNIT - 1 BED C 432 CUFT
1/8" = 1'-0"LU117
4 UNIT - 1 BED E 495 CUFT
1/8" = 1'-0"LU117
5 UNIT - 2 BED A 447 CUFT
1/8" = 1'-0"LU117
7 UNIT - 2 BED C 300 CUFT
1/8" = 1'-0"LU117
8 UNIT - 2 BED D 342 CUFT
1/8" = 1'-0"LU117
9 UNIT - 2 BED E 415 CUFT
1/8" = 1'-0"LU117
6 TOWNHOME 3BED TYP KEY
1/8" = 1'-0"LU117
10 TOWNHOME 2BED TYP KEY 2ND STORY 557 CUFT
DWREF
W/D
W/D
DW
W/D
DW
W/D
W/D
W/D
W/D
W/D
UP W/D
DNSTORAGE
8' - 0"
3' - 11"
STORAGE
6' - 0"
8' - 0"
STORAGE
6' - 5"
8' - 7"
STORAGE
12' - 5"
4' - 0"
STORAGE
4' - 0"
4' - 7"
3' - 0"
5' - 0"
3' - 1"
9' - 3"
5' - 4"
4' - 3"
STORAGE
STORAGE
5' - 8 1/2"8' - 1"
STORAGE
6' - 5"
9' - 8"
STORAGE UNIT KEY
MARCH 02, 2023 LU117
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/8" = 1'-0"LU117
2 UNIT - 1 BED B 282 CUFT
1/8" = 1'-0"LU117
3 UNIT - 1 BED C 432 CUFT
1/8" = 1'-0"LU117
4 UNIT - 1 BED E 495 CUFT
1/8" = 1'-0"LU117
5 UNIT - 2 BED A 447 CUFT
1/8" = 1'-0"LU117
7 UNIT - 2 BED C 300 CUFT
1/8" = 1'-0"LU117
8 UNIT - 2 BED D 342 CUFT
1/8" = 1'-0"LU117
9 UNIT - 2 BED E 415 CUFT
1/8" = 1'-0"LU117
6 TOWNHOME 3BED TYP KEY
1/8" = 1'-0"LU117
10 TOWNHOME 2BED TYP KEY 2ND STORY 557 CUFT
DWREF
W/D
W/D
DW
W/D
DW
W/D
W/D
W/D
W/D
W/D
UP W/D
DNSTORAGE
8' - 0"
3' - 11"
STORAGE
6' - 0"
8' - 0"
STORAGE
6' - 5"
8' - 7"
STORAGE
12' - 5"
4' - 0"
STORAGE
4' - 0"
4' - 7"
3' - 0"
5' - 0"
3' - 1"
9' - 3"
5' - 4"
4' - 3"
STORAGE
STORAGE
5' - 8 1/2"8' - 1"
STORAGE
6' - 5"
9' - 8"
STORAGE UNIT KEY
MARCH 02, 2023 LU117
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/8" = 1'-0"LU117
2 UNIT - 1 BED B 282 CUFT
1/8" = 1'-0"LU117
3 UNIT - 1 BED C 432 CUFT
1/8" = 1'-0"LU117
4 UNIT - 1 BED E 495 CUFT
1/8" = 1'-0"LU117
5 UNIT - 2 BED A 447 CUFT
1/8" = 1'-0"LU117
7 UNIT - 2 BED C 300 CUFT
1/8" = 1'-0"LU117
8 UNIT - 2 BED D 342 CUFT
1/8" = 1'-0"LU117
9 UNIT - 2 BED E 415 CUFT
1/8" = 1'-0"LU117
6 TOWNHOME 3BED TYP KEY
1/8" = 1'-0"LU117
10 TOWNHOME 2BED TYP KEY 2ND STORY 557 CUFT
DWREF
W/D
W/D
DW
W/D
DW
W/D
W/D
W/D
W/D
W/D
UP W/D
DNSTORAGE
8' - 0"
3' - 11"
STORAGE
6' - 0"
8' - 0"
STORAGE
6' - 5"
8' - 7"
STORAGE
12' - 5"
4' - 0"
STORAGE
4' - 0"
4' - 7"
3' - 0"
5' - 0"
3' - 1"
9' - 3"
5' - 4"
4' - 3"
STORAGE
STORAGE
5' - 8 1/2"8' - 1"
STORAGE
6' - 5"
9' - 8"
STORAGE UNIT KEY
MARCH 02, 2023 LU117
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/8" = 1'-0"LU117
2 UNIT - 1 BED B 282 CUFT
1/8" = 1'-0"LU117
3 UNIT - 1 BED C 432 CUFT
1/8" = 1'-0"LU117
4 UNIT - 1 BED E 495 CUFT
1/8" = 1'-0"LU117
5 UNIT - 2 BED A 447 CUFT
1/8" = 1'-0"LU117
7 UNIT - 2 BED C 300 CUFT
1/8" = 1'-0"LU117
8 UNIT - 2 BED D 342 CUFT
1/8" = 1'-0"LU117
9 UNIT - 2 BED E 415 CUFT
1/8" = 1'-0"LU117
6 TOWNHOME 3BED TYP KEY
1/8" = 1'-0"LU117
10 TOWNHOME 2BED TYP KEY 2ND STORY 557 CUFT
DWREF
W/D
W/D
DW
W/D
DW
W/D
W/D
W/D
W/D
W/D
UP W/D
DNSTORAGE
8' - 0"
3' - 11"
STORAGE
6' - 0"
8' - 0"
STORAGE
6' - 5"
8' - 7"
STORAGE
12' - 5"
4' - 0"
STORAGE
4' - 0"
4' - 7"
3' - 0"
5' - 0"
3' - 1"
9' - 3"
5' - 4"
4' - 3"
STORAGE
STORAGE
5' - 8 1/2"8' - 1"
STORAGE
6' - 5"
9' - 8"
STORAGE UNIT KEY
MARCH 02, 2023 LU117
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/8" = 1'-0"LU117
2 UNIT - 1 BED B 282 CUFT
1/8" = 1'-0"LU117
3 UNIT - 1 BED C 432 CUFT
1/8" = 1'-0"LU117
4 UNIT - 1 BED E 495 CUFT
1/8" = 1'-0"LU117
5 UNIT - 2 BED A 447 CUFT
1/8" = 1'-0"LU117
7 UNIT - 2 BED C 300 CUFT
1/8" = 1'-0"LU117
8 UNIT - 2 BED D 342 CUFT
1/8" = 1'-0"LU117
9 UNIT - 2 BED E 415 CUFT
1/8" = 1'-0"LU117
6 TOWNHOME 3BED TYP KEY
1/8" = 1'-0"LU117
10 TOWNHOME 2BED TYP KEY 2ND STORY 557 CUFT
DWREF
W/D
W/D
DW
W/D
DW
W/D
W/D
W/D
W/D
W/D
UP W/D
DNSTORAGE
8' - 0"
3' - 11"
STORAGE
6' - 0"
8' - 0"
STORAGE
6' - 5"
8' - 7"
STORAGE
12' - 5"
4' - 0"
STORAGE
4' - 0"
4' - 7"
3' - 0"
5' - 0"
3' - 1"
9' - 3"
5' - 4"
4' - 3"
STORAGE
STORAGE
5' - 8 1/2"8' - 1"
STORAGE
6' - 5"
9' - 8"
STORAGE UNIT KEY
MARCH 02, 2023 LU117
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/8" = 1'-0"LU117
2 UNIT - 1 BED B 282 CUFT
1/8" = 1'-0"LU117
3 UNIT - 1 BED C 432 CUFT
1/8" = 1'-0"LU117
4 UNIT - 1 BED E 495 CUFT
1/8" = 1'-0"LU117
5 UNIT - 2 BED A 447 CUFT
1/8" = 1'-0"LU117
7 UNIT - 2 BED C 300 CUFT
1/8" = 1'-0"LU117
8 UNIT - 2 BED D 342 CUFT
1/8" = 1'-0"LU117
9 UNIT - 2 BED E 415 CUFT
1/8" = 1'-0"LU117
6 TOWNHOME 3BED TYP KEY
1/8" = 1'-0"LU117
10 TOWNHOME 2BED TYP KEY 2ND STORY 557 CUFT
IN-UNIT STORAGE TYPICAL FLOOR PLANS
2 BED UNIT
1 BED UNIT
1 BED UNIT
TYPICAL STORY
GROUND STORY
1 BED UNIT
2 BED UNIT
2 BED UNIT
2 BED UNIT
3 BED TOWNHOME UNIT
447 CUFT
495 CUFT
282 CUFT
432 CUFT 342 CUFT
557 CUFT415 CUFT
300 CUFT
STORAGE IN UNIT PLANS
MARCH 02, 2023 LU116
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1" = 60'-0"LU116
1 GROUND STORY STORAGE UNIT KEY
1" = 60'-0"LU116
2 3RD STORY STORAGE UNIT KEY
1" = 60'-0"LU116
3 4TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
4 5TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
5 8TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
6 6TH & 7TH STORY STORAGE UNIT KEY
1" = 60'-0"LU116
1 GROUND STORY STORAGE UNIT KEY
1" = 60'-0"LU116
2 3RD STORY STORAGE UNIT KEY
1" = 60'-0"LU116
3 4TH STORY STORAGE UNIT KEY
6TH & 7TH STORY
3 BED TOWNHOME
NG
NG
KITCHEN
3' - 3"
BEDRO
OM 1
BATH 1
STORAGE
BEDROOM
2 LIVING
DINING
KITCHEN
BALCO
NY
BATH 2
CLOSET
5' - 0"24' - 11"
30' - 8"
10' - 6" 24' - 4"
35' - 7"
6' - 4"
8' - 0"CLOSET
W/D
IN-UNIT STORAGE MINIMUM DIMENSIONS
3’ - 0”
9FT HEIGHT, TYP.
8’ - 0”
Attachment 5
123
LU SUBMITTAL 05 JULY 05, 2023
2' - 9"
1/4" / 1'-0"1/4" / 1'-0"
2' - 6"
5' - 10"
6' - 0"
9' - 0"
ROOF DIAGRAM
MAY 24, 2023 LU123
170 SAN ZENO WAY
SUNNYVALE, CA 94086
ROOFTOP VISIBLITY
NORTH - SOUTH LINE OF SITE
MECHANICAL EQUIPMENT HEIGHT
EAST - WEST LINE OF SITE
PARAPET
HEAT
PUMP
HEAT
PUMP
CORRIDOR
SUPPLY FAN
MECHANICAL EQUIPMENT ABOVE PARAPET TO BE
PAINTED TO MATCH PARAPET
LAWRENCE EXPY
KIFER RD
SAN ZENO WAY
SOLAR PANELS - 5 KW PV SYSTEM SOLAR PANELS - 5 KW PV SYSTEM
MECHANICAL EQUIPMENT ABOVE PARAPET TO BE
PAINTED TO MATCH PARAPET
MECHANICAL EQUIPMENT ABOVE PARAPET TO BE
PAINTED TO MATCH PARAPET
2 4
3 5
1 Attachment 5
124
LU SUBMITTAL 05 JULY 05, 2023
29 1/2"
8 1/2"5 1/2"8 1/2"
OFFSET
12"
5" 2" 2"
BUILDING CORNICE
CORNICE DETAIL AT WALL SHIFT
CORNICE DETAIL AT PARAPET1
2 2
1 Attachment 5
125
LU SUBMITTAL 05 JULY 05, 2023
0' - 8"
3' - 6"
3' - 6"
RAIL DETAILS
JUNE 30, 2022 LU48
170 SAN ZENO WAY
SUNNYVALE, CA 94086
0' - 8"
3' - 6"
3' - 6"
RAIL DETAILS
JUNE 30, 2022 LU48
170 SAN ZENO WAY
SUNNYVALE, CA 94086
0' - 8"
3' - 6"
RAIL DETAILS
JUNE 30, 2022 LU48
170 SAN ZENO WAY
SUNNYVALE, CA 94086
9"4 1/2"1 1/2"
9"4 1/2"1 1/2"
0' - 8"
3' - 6"
3' - 6"
RAIL DETAILS
JUNE 30, 2022 LU48
170 SAN ZENO WAY
SUNNYVALE, CA 94086
GUARDRAIL DETAILS
GUARD RAIL DETAIL1
CORNICE DETAIL AT WALL SHIFT2
STAINLESS STEEL
INFILL PANEL
STAINLESS STEEL
CHANNEL
STAINLESS STEEL
GUARDRAIL FRAME
CONCRETE PAVER
WITH PEDESTAL SYSTEM
CONCRETE PAVER
WITH PEDESTAL SYSTEM
THIN BRICK CORNICE
GUARDRAIL, RAIL SHOE
HSS BASE FRAME TO MOUNT
GUARDRAIL SYSTEM
GLASS GUARDRAIL
ALUMINUM GUARDRAIL
TOP CAP
KNIFE PLATE WITH
ANCHOR BOLTS
2 1
Attachment 5
126
LU SUBMITTAL 05 JULY 05, 2023
VISUAL VARIATION AT TEXTURED BRICK - BASE BRICK TEXTURE PROFILE
BRICK TEXTURE EXAMPLE
BASE - BRICK TEXTURE
2.89 BASE: FACE BRICK TEXTURE
WILL PROVIDE ADDITIONAL
VISUAL VARIATION CREATED BY
NATURAL LIGHT THROUGHOUT
THE DAY.
SOLDIER COURSE BRICK
CORNICE BETWEEN BASE &
MIDDLE ELEMENTS.
MIDDLE: THIN BRICK
Attachment 5
127
LU SUBMITTAL 05 JULY 05, 2023
1/2"
2 1/2"
MAX ALLOWABLE LENGTH 18'-0"
VARIES
STUCCO
JULY 20, 2022 LU49
170 SAN ZENO WAY
SUNNYVALE, CA 94086
STUCCO OVER METAL LATH
WATERPROOFING SYSTEM
STUCCO CONTROL JOINT
GYPSUM SHEATHING
CONTROL JOINT DETAIL
Attachment 5
128
LU SUBMITTAL 05 JULY 05, 2023
WND R.O.
WRB
THIN BRICK OVER SCR
BROWN COAT OVER M
(1) LAYER OF GLASS M
SHEATHING
NAIL FLANGE WINDOW
SEALANT
WINDOW SILL DETAIL, TYP
GRID
WND R.O.
WRB
22g FLASHING WITH HEMMED EDGE
NAIL FLANGE WINDOW
THIN BRICK OVER SCRATCH AND
BROWN COAT OVER METAL LATH
(1) LAYER OF GLASS MAT
SHEATHING
OPEN JOINT
WINDOW HEAD DETAIL, TYP
3" MIN
WND R.O.
WRB
THIN BRICK OVER SCRATCH AND
BROWN COAT OVER METAL LATH
(1) LAYER OF GLASS MAT
SHEATHING
NAIL FLANGE WINDOW
SEALANT
GRID
WND R.O.
3" MIN
NAIL FLANGE WINDOW
WRB
THIN BRICK OVER SCRATCH AND
BROWN COAT OVER METAL LATH
(1) LAYER OF GLASS MAT SHEATHING
WND R.O.
WRB
THIN BRICK OVER SCRATCH AND
BROWN COAT OVER METAL LATH
(1) LAYER OF GLASS MAT
SHEATHING
NAIL FLANGE WINDOW
SEALANT
GRID
WND R.O.
3" MIN
NAIL FLANGE WINDOW
WRB
THIN BRICK OVER SCRATCH AND
BROWN COAT OVER METAL LATH
(1) LAYER OF GLASS MAT SHEATHING
WINDOW DETAILS - THIN BRICK
Attachment 5
129
LU SUBMITTAL 05 JULY 05, 2023
EXHIBITS
Attachment 5
130
LU SUBMITTAL 05 JULY 05, 2023
SUNNYVALE GATEWAY SIGN - LAWRENCE STATION
9"
A1 - FRONT VIEW
SCALE: 3/8”=1’0”1 A1 - BACK VIEW
SCALE: 3/8”=1’0”2
A1 - TOP VIEW
SCALE: 3/8”=1’0”4
A1- SIDE VIEW
SCALE: 3/8”=1’0”3
Powder coated aluminum sign panel
Color to match to RGB Color (63,68,109)
1” thick push through frosted acrylic logo,
internally illuminated on face and returns
Green color to match Sunnyvale Green
1” thick push through frosted acrylic letters,
internally illuminated on face and returns
1” thick push through frosted acrylic letters,
internally illuminated on face and returns
Font: Avenir Medium
Brushed aluminum sign cabinet
M
//
COMMERCIAL
STREET
MATCHLINE ~SEE ABOVE
KIFER ROAD
KIFER ROAD - STA 24+00 TO STA 29+00
SCALE: 1" = 20'
3"
6"
8"8" 2'-8"
8"2'-5"1'-8"
1'-6"5"
4'-0"
3'-6"
8'-2"1'-8"
3"
14'-6"1'-0"
16'-0"
1'-0"
3"
4'-0"
3'-6"
3"
1'-0"
16'-0"
EXPERIENCE DESIGN
Co pyright © 2021 Hellmuth, Obata & Kassabaum, Inc. ORIGINAL DRAWING IS 11 X 17. DO NOT SCALE CONTENTS OF THIS DRAWING.
No.
1 2
3 DESCRIPTION DATEPROJECT INFORMATION
Scope: Signage
Phase: Schematic Design
Issued For: Client review
ISI INTUITIVE SURGICAL HQ
Intuitive Surgical - Sunnyvale
Project Number:
Date: 06/22/2022
SUNNYVALE GATEWAY SIGNSUNNYVALE DIRECTIONAL SIGN TYPE A Attachment 5
131
LU SUBMITTAL 05 JULY 05, 2023
TRASH EXHIBIT - TRASH ENCLOSURE
ROOF PLAN VIEW
EAST / WEST ELEVATIONSOUTH / FRONT ELEVATION
FRONT ELEVATION VIEW STREET VIEW
STEEL GATE WITH THERMORY
WOOD BOARDS
WIRE CABLE
FOR CLIMBING PLANTS
4X4 WOOD BOARDS OVER
STEEL STRUCTURE
CMU WALL W/ STUCCO FINISH COAT
9’- 2”
1’ - 0”
Attachment 5
132
LU SUBMITTAL 05 JULY 05, 2023
EV
EV
EV
SL
AL
EV
EV
EV
SL
AL
Sunnyvale Front Load Truck-32.3
6'-9"
3'-8"
1'
6'-9"
3'-8"
1'
6'-9"
1'
6'-9"
3'-8"
1'
6'-9"
3'-8"
1'
6'-9"
3'-8"
1' 6'-9"
3'-8"
16'
16'-11
2"
NEIGHBORING OFFICE
19'-10"
RESIDENTIAL
6'-9"
4'-6" 1'
6'-9"
4'-6"
6'-9"
4'-6"1'
6'-9"
4'-6"
5'
10'
3'-8"
DN
UP
UP
DN
DN
UP
UP
UP
x1
x7
15 15
2.14567891014
F
G
J
K
12 115'-10"
60'-0"18'-0"
RAMP UP
2'-5 1/4" 12'-0"
29'-11
1/4" 27'-6" 27'-6" 27'-6" 27'-6" 27'-6" 27'-6" 27'-6"
22'-0
3/4" 30'-2" 14'-4" 28'-7" 17'-6"
28'-5"
27'-7"
3 BED TOWNHOME 2 BED TOWNHOME
TRASH
3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME
TRASH
3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
THE SHOP
PACKAGE ROOM
BOH
PARLOR
THE POST
OFFICE
TRANSFORMER
1 24'-0"
DRIVE
AISLE
24'-0"
DRIVE AISLE
STAIR 2
STAIR 1
STAIR 3
STAIR 4
ELEV 4 ELEV 3
ELEV 1 & 2
90.00°
ELECTRICALUTILITY
RESIDENTIAL
PARKING
ELECTRICAL
ELECTRICAL
MECHANICAL
ELEC
ELEC
R.R.
13 3 BED TOWNHOME 2 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME xC
24'-0"
DRIVE
AISLE
211
H
x3
x4
x5
x6
3 x2
5.26.17.28.18.29.110.111.112.112.313.113.2
28'-6"25'-7"4'-11"14'-6"
18'-0"
18'-8
1/2"
25'-0"
25'-0"
17'-4 1/2"
11'-9"
73'-6"
xD
70'-4"
16 16
2'-5 1/4"
16'-4
1/4"
14'-2
1/2" 21'-0" 15'-6" 21'-0" 21'-0" 25'-0"
21'-8
1/2"
13'-10
3/4"
25'-10
3/4" 21'-0"
26'-5
1/4"
245'-5 1/4"
349'-6 1/4"
70'-4"
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
DRAWING TITLE
1150 - 1170 SAN ZENO WAY
SUNNYVALE, CA
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DATE
SCALE
DRAWING NO.
CONSULTANT
OVERALL SITE PLAN
TR0.1
ARCHITECT
OWNER / DEVELOPER
NO. DATE ISSUED BYISSUE / REVISION
BDE - JONES
PROMETHIUS
SS
02/27/23
PROPOSED TRASH
ENCLOSURE (COMMERCIAL)
MAIN RESIDENTIAL
INTERIOR TRASH
COLLECTION ROOM
SECONDARY TRASH COLLECTION ROOM
1 /32" = 1' - 0"PATH OF TRAVEL - TOWN HOUSES TO TRASH COLLECTION ROOMPATH OF TRAVEL - CONTAINERS
EXISTING OFFICE ENCLOSURES TO BE
REMOVED AND RELOCATED TO
PROPOSED CENTRAL ENCLOSURE
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
CONSULTANT
BDE - JONES
TRASH STAGING AREA MAIN TRASH COLLECTION ROOM SECONDARY TRASH COLLECTION ROOM
PATH OF TRAVEL FROM TOWN HOUSES TO TRASH
COLLECTION ROOM
TRASH EXHIBIT - SITE PLAN
RESIDENTIAL WASTE
STAGING AREA
(3 Parking Spaces -
Sides - visual fence screening)
Attachment 5
133
LU SUBMITTAL 05 JULY 05, 2023
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
CONSULTANT
BDE - JONES
TRASH STAGING AREA MAIN TRASH COLLECTION ROOM SECONDARY TRASH COLLECTION ROOM
PATH OF TRAVEL FROM TOWN HOUSES TO TRASH
COLLECTION ROOM
DN
UP
A
B.1
C.1
L
4.1 7.1
7.310.2
10.3 12.2 1
2 BED C
1 BED A
1 BED A
2 BED G
2 BED A
2 BED B
1 BED C
1 BED A 2 BED B 1 BED A
1 BED C+
1 BED B
1 BED B
1 BED D
1 BED B 1 BED B
1 BED B1 BED B
STUDIO A STUDIO A
STRENGTH STUDIO
2 BED A2 BED A
2 BED B
1 BED A
1 BED A
2 BED D
1 BED A
1 BED E
1 BED D
1 BED A1 BED A
STUDIO C
1 BED F
STUDIO D
DEN
STUDIO A
STUDIO A
STUDIO A
POOL
SPA
AMENITY POOL
DECK
AMENITY
COURTYARD
TRASH TRASH
STAIR 2
STAIR 1
STAIR 3
ELEV 3
ELEV 1 & 2
x2.5
11.2 x7.1
ELEC/IDF
5.1 16
16 AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
DRAWING TITLE
1150 - 1170 SAN ZENO WAY
SUNNYVALE, CA
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DATE
SCALE
DRAWING NO.
CONSULTANT
OVERALL PLAN - LEVEL 4
TR0.2
ARCHITECT
OWNER / DEVELOPER
NO. DATE ISSUED BYISSUE / REVISION
BDE - JONES
PROMETHIUS
SS
02/27/23
MAIN TRASH COLLECTION ROOM
SECONDARY CHUTE VESTIBULES
1 /32" = 1' - 0"
OVERALL PLAN - LEVEL 4
TRASH EXHIBIT - UPPER STORIES
97’-6”
95’-0”
78’-6”
27’-0”
45’-0”
71’-3” 46’-6”
Attachment 5
134
LU SUBMITTAL 05 JULY 05, 2023
WASTE
FOOD
SCRAPS
35 GAL.
REC PR
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
REC MC
3 FT
ACCESS
DOOR
96 GAL.
REC PR
WASTE
30"Ø CHUTE
HOPPER
96 GAL.
REC PR
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-1 SECTION B-2
HOPPER
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-3
24"Ø CHUTE
LEVEL 2
WASTE
MAX) AND FLOOR DRAIN. FLOOR LEVEL UNDER COMPACTOR.
3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIGH-GLOSS ENAMEL PAINT, 8'-0" AFF.
4. INSTALL WALL PROTECTION: 12"Wx5"H CONCRETE CURB AT BASE OF ALL NON-CONCRETE WALLS. DO NOT INSTALL THE CURB AROUND THE COMPACTORS/BISORTER OR POWER PACKS.
5. 10'-0" ROLL UP DOOR AND 3FT EXIT DOOR.
6. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/FT PER 2019 CBC.
7. (1) 30"Ø GRAVITY CHUTE FOR LOOSE WASTE & (2) 24"Ø GRAVITY CHUTES FOR PAPER & CONTAINER RECYCLING. CHUTES SHALL TERMINATE AT 5'-9" AFF.
8. MCP: CHUTE MASTER CONTROL PANEL SHALL BE WALL-MOUNTED 60" AFF. MUST ALLOW LOCK DOWN OF CHUTE INTAKES FOR EXCHANGING CONTAINERS AND WASHING CHUTES. REQUIRES 120V 15A DEDICATED SERVICE.
9. AC: 2HP CHUTE AIR COMPRESSOR SHALL BE MOUNTED72" AFF. REQUIRES 110V 15A SERVICE OUTLETS.
10. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. REQUIRES 120V 15A SERVICE OUTLETS.
11. HB: HOT AND COLD HOSE BIB SHALL BE WALL-MOUNTED 60" AFF.
12. PROVIDE ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. 4000lb CAPACITY; TURNING RADIUS: 45.5". REQUIRES 120V 15A SERVICE OUTLETS.
13. CHUTE DISCHARGE DOOR: TYPE-A, HORIZONTALLY INSULATED SLIDING-STEEL DOOR, HELD OPEN BY 165° F FUSIBLE LINK.
14. (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE.
CHUTE INTAKE VESTIBULES:
15. CHUTE INTAKE VESTIBULES SHALL BE 1HR FIRE-RATED WITH 1HR FIRE-RATED DOOR; 5'-0" MIN REQUIRED PER ADA STANDARDS - RESIDENTIAL ACCESS. PROVIDE (3) SELF CLOSING, 15x18 BOTTOM
HINGED, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING INTAKE DOORS TO DISPOSE TRASH AND RECYCLING PER CBC 713.13.1. POWER TO INTAKE DOORS SUPPLIED BY MCP. SEE DETAIL 1T2.0.
16. CHUTE SHAFT SHALL NOT BE ERECTED UNTIL CHUTE HAS BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, DOUBLE STUD-WALLS ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INTERIOR OF SHAFT SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES (BY OTHERS).
17. PROVIDE 18X18 SIDE HINGED, AUTOMATIC OPENING, ELECTRICALLY INTERLOCKED THRU-WALL INTAKE DOORS THAT DISPOSE INTO CONTAINERS PER CBC 713.13.1. SEE DETAILS 2/T2.0.
18. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND SQUARED FLOOR OPENINGS AT WOOD-FRAME CONSTRUCTION. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE CHUTE. SEE DETAIL 9/T2.0 FOR ANCHORING AND MASON BRA-RED SOUND ISOLATION PAD ASSEMBLY. POUR RINGS WILL VARY BASED ON THICKNESS OF FLOOR SLAB AND SHALL BE PROVIDED BY MANUFACTURER.
GENERAL NOTES:
1. ANY DESIGNS OR DESIGN SOLUTIONS PRESENTED IN THIS DRAWING OR SPECIFICATION, WHICH ARE
DIRECT OR IMPLIED, INCLUDING NARRATIVES, DRAWINGS, OR DIAGRAMS, ARE HEREBY CLARIFIED AS
EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS OR DESIGNS SUITABLE FOR CONSTRUCTION.
2. OMISSIONS FROM DRAWINGS OR SPECIFICATIONS, OR THE INACCURATE DESCRIPTION OF DETAILS OF
WORK, WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND
SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INACCURATELY DESCRIBED DETAILS OF THE WORK. WORK
SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ALL EXISTING FIELD CONDITIONS AND ANY DISCREPANCIES OR INCONSISTENCIES.
LEVEL 1.5
LEVEL 1
LEVEL 1.5
LEVEL 1
96 GAL.
REC PR
35 GAL FOOD SCRAP CART
35 GAL.
96 GAL CART
96 GAL.
HOPPER W/
THRU-WALL OPENING
HOPPER
TRASH COLLECTION ROOM- LOOSE
LEVEL3-8
TRASH
96 GAL.
REC MC
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
3 FT
ACCESS
DOOR
FOOD
SCRAPS
35 GAL.
3 CY
WASTE
CONTAINER
96 GAL.
REC PR
CHUTE
MASTER
CONTROL
SERVICE OUTLETS. (TYP)
AIR COMPRESSORS
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
ELECTRIC
PALLET JACK
F.D.
B-3
B-2
B-1
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
ODOR CONTROL
WHEEL STOP 12"W x 5"H
WASTE
E
11TRASH COLLECTION ROOM- LOOSE
LEVEL 1
HOT/COLD
HOSE BIB
HOT/COLD
HOSE BIB
AMERICAN TRASH MANAGEM
1900 POWELL STREET, SUITE
EMERYVILLE, CALIFORNIA 94
P: 415.292.5400
F: 415.292.5410
[email protected]
DRAWING TITLE
1150 - 1170 SAN
SUNNYVAL
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DATE
SCALE
DRAW
CONSULTANT
MAIN TRASH COLLE
ARCHITECT
OWNER / DEVELOPER
NO. DATE ISSUE /
BDE - JONES
PROMETHIUS
SS
02/27/23
3/16" = 1' - 0"
WASTE
FOOD
SCRAPS
35 GAL.
REC PR
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
REC MC
3 FT
ACCESS
DOOR
96 GAL.
REC PR
WASTE
30"Ø CHUTE
HOPPER
96 GAL.
REC PR
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-1 SECTION B-2
HOPPER
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-3
24"Ø CHUTE
LEVEL 2
WASTE
MAX) AND FLOOR DRAIN. FLOOR LEVEL UNDER COMPACTOR.
3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIG ENAMEL PAINT, 8'-0" AFF.
4. INSTALL WALL PROTECTION: 12"Wx5"H CONCRETE CURB AT BASE OF ALL NON-CONCRETE W NOT INSTALL THE CURB AROUND THE COMPACTORS/BISORTER OR POWER PACKS.
5. 10'-0" ROLL UP DOOR AND 3FT EXIT DOOR.
6. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/FT PER 2019 CBC.
7. (1) 30"Ø GRAVITY CHUTE FOR LOOSE WASTE & (2) 24"Ø GRAVITY CHUTES FOR PAPER & C RECYCLING. CHUTES SHALL TERMINATE AT 5'-9" AFF.
8. MCP: CHUTE MASTER CONTROL PANEL SHALL BE WALL-MOUNTED 60" AFF. MUST ALLOW LO OF CHUTE INTAKES FOR EXCHANGING CONTAINERS AND WASHING CHUTES. REQUIRES DEDICATED SERVICE.
9. AC: 2HP CHUTE AIR COMPRESSOR SHALL BE MOUNTED72" AFF. REQUIRES 110V 15A SERVICE O
10. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. REQUIRES 120V 15A SERVICE OU
11. HB: HOT AND COLD HOSE BIB SHALL BE WALL-MOUNTED 60" AFF.
12. PROVIDE ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. 4000lb CAPACITY; RADIUS: 45.5". REQUIRES 120V 15A SERVICE OUTLETS.
13. CHUTE DISCHARGE DOOR: TYPE-A, HORIZONTALLY INSULATED SLIDING-STEEL DOOR, HELD 165° F FUSIBLE LINK.
14. (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE.
CHUTE INTAKE VESTIBULES:
15. CHUTE INTAKE VESTIBULES SHALL BE 1HR FIRE-RATED WITH 1HR FIRE-RATED DOOR; REQUIRED PER ADA STANDARDS - RESIDENTIAL ACCESS. PROVIDE (3) SELF CLOSING, 15x18
HINGED, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING INTAKE DOORS TO DISPOSE TR RECYCLING PER CBC 713.13.1. POWER TO INTAKE DOORS SUPPLIED BY MCP. SEE DETAIL 1T2.
16. CHUTE SHAFT SHALL NOT BE ERECTED UNTIL CHUTE HAS BEEN INSTALLED. FOR SOUND P PURPOSES, DOUBLE STUD-WALLS ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INT
SHAFT SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES (BY OT
17. PROVIDE 18X18 SIDE HINGED, AUTOMATIC OPENING, ELECTRICALLY INTERLOCKED THRU-WA DOORS THAT DISPOSE INTO CONTAINERS PER CBC 713.13.1. SEE DETAILS 2/T2.0.
18. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND SQUARED FLOOR OPE WOOD-FRAME CONSTRUCTION. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETR SECURE CHUTE. SEE DETAIL 9/T2.0 FOR ANCHORING AND MASON BRA-RED SOUND ISOLA ASSEMBLY. POUR RINGS WILL VARY BASED ON THICKNESS OF FLOOR SLAB AND SHALL BE P BY MANUFACTURER.
GENERAL NOTES:
1. ANY DESIGNS OR DESIGN SOLUTIONS PRESENTED IN THIS DRAWING OR SPECIFICATION, W
DIRECT OR IMPLIED, INCLUDING NARRATIVES, DRAWINGS, OR DIAGRAMS, ARE HEREBY CLA
EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS OR DESIGNS SUITA CONSTRUCTION.
2. OMISSIONS FROM DRAWINGS OR SPECIFICATIONS, OR THE INACCURATE DESCRIPTION OF D
WORK, WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAW
SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CON
FROM PERFORMING SUCH OMITTED OR INACCURATELY DESCRIBED DETAILS OF THE WOR
SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE D AND SPECIFICATIONS.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO S CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ALL EXISTIN CONDITIONS AND ANY DISCREPANCIES OR INCONSISTENCIES.
LEVEL 1.5
LEVEL 1
LEVEL 1.5
LEVEL 1
96 GAL.
REC PR
35 GAL FOOD SCRAP CART
35 GAL.
96 GAL CART
96 GAL.
HOPPER W/
THRU-WALL OPENING
HOPPER
TRASH COLLECTION ROOM- LOOSE
LEVEL3-8
TRASH
96 GAL.
REC MC
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
3 FT
ACCESS
DOOR
FOOD
SCRAPS
35 GAL.
3 CY
WASTE
CONTAINER
96 GAL.
REC PR
CHUTE
MASTER
CONTROL
SERVICE OUTLETS. (TYP)
AIR COMPRESSORS
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
ELECTRIC
PALLET JACK
F.D.
B-3
B-2
B-1
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
ODOR CONTROL
WHEEL STOP 12"W x 5"H
WASTE
E
11TRASH COLLECTION ROOM- LOOSE
LEVEL 1
HOT/COLD
HOSE BIB
HOT/COLD
HOSE BIB
WASTE
FOOD
SCRAPS
35 GAL.
REC PR
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
REC MC
3 FT
ACCESS
DOOR
96 GAL.
REC PR
WASTE
30"Ø CHUTE
HOPPER
96 GAL.
REC PR
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-1 SECTION B-2
HOPPER
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-3
24"Ø CHUTE
LEVEL 2
WASTE
SHEET NOTES:
RESIDENTIAL TRASH TERMINATION ROOM
1. TRASH COLLECTION ROOM IS PART OF 2HR FIRE-RATED TRASH CHUTE SHAFT - RESTRICTED ACCESS.
2. FLOOR SHALL BE FINISHED WITH WATERPROOF DECK COATING. FLOOR TO HAVE MINIMAL SLOPE (1° MAX) AND FLOOR DRAIN. FLOOR LEVEL UNDER COMPACTOR.
3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIGH-GLOSS ENAMEL PAINT, 8'-0" AFF.
4. INSTALL WALL PROTECTION: 12"Wx5"H CONCRETE CURB AT BASE OF ALL NON-CONCRETE WALLS. DO NOT INSTALL THE CURB AROUND THE COMPACTORS/BISORTER OR POWER PACKS.
5. 10'-0" ROLL UP DOOR AND 3FT EXIT DOOR.
6. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/FT PER 2019 CBC.
7. (1) 30"Ø GRAVITY CHUTE FOR LOOSE WASTE & (2) 24"Ø GRAVITY CHUTES FOR PAPER & CONTAINER RECYCLING. CHUTES SHALL TERMINATE AT 5'-9" AFF.
8. MCP: CHUTE MASTER CONTROL PANEL SHALL BE WALL-MOUNTED 60" AFF. MUST ALLOW LOCK DOWN OF CHUTE INTAKES FOR EXCHANGING CONTAINERS AND WASHING CHUTES. REQUIRES 120V 15A DEDICATED SERVICE.
9. AC: 2HP CHUTE AIR COMPRESSOR SHALL BE MOUNTED72" AFF. REQUIRES 110V 15A SERVICE OUTLETS.
10. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. REQUIRES 120V 15A SERVICE OUTLETS.
11. HB: HOT AND COLD HOSE BIB SHALL BE WALL-MOUNTED 60" AFF.
12. PROVIDE ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. 4000lb CAPACITY; TURNING RADIUS: 45.5". REQUIRES 120V 15A SERVICE OUTLETS.
13. CHUTE DISCHARGE DOOR: TYPE-A, HORIZONTALLY INSULATED SLIDING-STEEL DOOR, HELD OPEN BY 165° F FUSIBLE LINK.
14. (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE.
CHUTE INTAKE VESTIBULES:
15. CHUTE INTAKE VESTIBULES SHALL BE 1HR FIRE-RATED WITH 1HR FIRE-RATED DOOR; 5'-0" MIN REQUIRED PER ADA STANDARDS - RESIDENTIAL ACCESS. PROVIDE (3) SELF CLOSING, 15x18 BOTTOM
HINGED, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING INTAKE DOORS TO DISPOSE TRASH AND RECYCLING PER CBC 713.13.1. POWER TO INTAKE DOORS SUPPLIED BY MCP. SEE DETAIL 1T2.0.
16. CHUTE SHAFT SHALL NOT BE ERECTED UNTIL CHUTE HAS BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, DOUBLE STUD-WALLS ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INTERIOR OF SHAFT SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES (BY OTHERS).
17. PROVIDE 18X18 SIDE HINGED, AUTOMATIC OPENING, ELECTRICALLY INTERLOCKED THRU-WALL INTAKE DOORS THAT DISPOSE INTO CONTAINERS PER CBC 713.13.1. SEE DETAILS 2/T2.0.
18. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND SQUARED FLOOR OPENINGS AT WOOD-FRAME CONSTRUCTION. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE CHUTE. SEE DETAIL 9/T2.0 FOR ANCHORING AND MASON BRA-RED SOUND ISOLATION PAD ASSEMBLY. POUR
RINGS WILL VARY BASED ON THICKNESS OF FLOOR SLAB AND SHALL BE PROVIDED BY MANUFACTURER.
GENERAL NOTES:
1. ANY DESIGNS OR DESIGN SOLUTIONS PRESENTED IN THIS DRAWING OR SPECIFICATION, WHICH ARE
DIRECT OR IMPLIED, INCLUDING NARRATIVES, DRAWINGS, OR DIAGRAMS, ARE HEREBY CLARIFIED AS
EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS OR DESIGNS SUITABLE FOR CONSTRUCTION.
2. OMISSIONS FROM DRAWINGS OR SPECIFICATIONS, OR THE INACCURATE DESCRIPTION OF DETAILS OF
WORK, WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND
SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INACCURATELY DESCRIBED DETAILS OF THE WORK. WORK
SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ALL EXISTING FIELD CONDITIONS AND ANY DISCREPANCIES OR INCONSISTENCIES.
LEVEL 1.5
LEVEL 1
LEVEL 1.5
LEVEL 1
96 GAL.
REC PR
35 GAL FOOD SCRAP CART
35 GAL.
96 GAL CART
96 GAL.
HOPPER W/
THRU-WALL OPENING
HOPPER
TRASH COLLECTION ROOM- LOOSE
LEVEL3-8
TRASH
96 GAL.
REC MC
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
3 FT
ACCESS
DOOR
FOOD
SCRAPS
35 GAL.
3 CY
WASTE
CONTAINER
96 GAL.
REC PR
CHUTE
MASTER
CONTROL
SERVICE OUTLETS. (TYP)
AIR COMPRESSORS
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
ELECTRIC
PALLET JACK
F.D.
B-3
B-2
B-1
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
ODOR CONTROL
WHEEL STOP 12"W x 5"H
WASTE
E
11TRASH COLLECTION ROOM- LOOSE
LEVEL 1
HOT/COLD
HOSE BIB
HOT/COLD
HOSE BIB
AMERIC
1900 PO
EMERYV
P: 415.2
F: 415.2
SBROWN
DRAWING TITLE
11 PROJECT NO.
PROJECT
DRAWN
APPROVED
DATE
SCALE
CONSULTANT
MAIN
ARCHITECT
OWNER / DEVELOP
NO. DA
BDE -
PROME
02 3/16"
WASTE
FOOD
SCRAPS
35 GAL.
REC PR
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
REC MC
3 FT
ACCESS
DOOR
96 GAL.
REC PR
WASTE
30"Ø CHUTE
HOPPER
96 GAL.
REC PR
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-1 SECTION B-2
HOPPER
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-3
24"Ø CHUTE
LEVEL 2
WASTE
SHEET NOTES:
RESIDENTIAL TRASH TERMINATION ROOM
1. TRASH COLLECTION ROOM IS PART OF 2HR FIRE-RATED TRASH CHUTE SHAFT - RESTRICTED ACCESS.
2. FLOOR SHALL BE FINISHED WITH WATERPROOF DECK COATING. FLOOR TO HAVE MINIMAL SLOPE (1° MAX) AND FLOOR DRAIN. FLOOR LEVEL UNDER COMPACTOR.
3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIGH-GLOSS ENAMEL PAINT, 8'-0" AFF.
4. INSTALL WALL PROTECTION: 12"Wx5"H CONCRETE CURB AT BASE OF ALL NON-CONCRETE WALLS. DO NOT INSTALL THE CURB AROUND THE COMPACTORS/BISORTER OR POWER PACKS.
5. 10'-0" ROLL UP DOOR AND 3FT EXIT DOOR.
6. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/FT PER 2019 CBC.
7. (1) 30"Ø GRAVITY CHUTE FOR LOOSE WASTE & (2) 24"Ø GRAVITY CHUTES FOR PAPER & CONTAINER RECYCLING. CHUTES SHALL TERMINATE AT 5'-9" AFF.
8. MCP: CHUTE MASTER CONTROL PANEL SHALL BE WALL-MOUNTED 60" AFF. MUST ALLOW LOCK DOWN OF CHUTE INTAKES FOR EXCHANGING CONTAINERS AND WASHING CHUTES. REQUIRES 120V 15A DEDICATED SERVICE.
9. AC: 2HP CHUTE AIR COMPRESSOR SHALL BE MOUNTED72" AFF. REQUIRES 110V 15A SERVICE OUTLETS.
10. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. REQUIRES 120V 15A SERVICE OUTLETS.
11. HB: HOT AND COLD HOSE BIB SHALL BE WALL-MOUNTED 60" AFF.
12. PROVIDE ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. 4000lb CAPACITY; TURNING RADIUS: 45.5". REQUIRES 120V 15A SERVICE OUTLETS.
13. CHUTE DISCHARGE DOOR: TYPE-A, HORIZONTALLY INSULATED SLIDING-STEEL DOOR, HELD OPEN BY 165° F FUSIBLE LINK.
14. (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE.
CHUTE INTAKE VESTIBULES:
15. CHUTE INTAKE VESTIBULES SHALL BE 1HR FIRE-RATED WITH 1HR FIRE-RATED DOOR; 5'-0" MIN REQUIRED PER ADA STANDARDS - RESIDENTIAL ACCESS. PROVIDE (3) SELF CLOSING, 15x18 BOTTOM
HINGED, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING INTAKE DOORS TO DISPOSE TRASH AND RECYCLING PER CBC 713.13.1. POWER TO INTAKE DOORS SUPPLIED BY MCP. SEE DETAIL 1T2.0.
16. CHUTE SHAFT SHALL NOT BE ERECTED UNTIL CHUTE HAS BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, DOUBLE STUD-WALLS ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INTERIOR OF SHAFT SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES (BY OTHERS).
17. PROVIDE 18X18 SIDE HINGED, AUTOMATIC OPENING, ELECTRICALLY INTERLOCKED THRU-WALL INTAKE DOORS THAT DISPOSE INTO CONTAINERS PER CBC 713.13.1. SEE DETAILS 2/T2.0.
18. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND SQUARED FLOOR OPENINGS AT WOOD-FRAME CONSTRUCTION. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE CHUTE. SEE DETAIL 9/T2.0 FOR ANCHORING AND MASON BRA-RED SOUND ISOLATION PAD ASSEMBLY. POUR RINGS WILL VARY BASED ON THICKNESS OF FLOOR SLAB AND SHALL BE PROVIDED BY MANUFACTURER.
GENERAL NOTES:
1. ANY DESIGNS OR DESIGN SOLUTIONS PRESENTED IN THIS DRAWING OR SPECIFICATION, WHICH ARE
DIRECT OR IMPLIED, INCLUDING NARRATIVES, DRAWINGS, OR DIAGRAMS, ARE HEREBY CLARIFIED AS
EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS OR DESIGNS SUITABLE FOR CONSTRUCTION.
2. OMISSIONS FROM DRAWINGS OR SPECIFICATIONS, OR THE INACCURATE DESCRIPTION OF DETAILS OF
WORK, WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND
SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INACCURATELY DESCRIBED DETAILS OF THE WORK. WORK
SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ALL EXISTING FIELD CONDITIONS AND ANY DISCREPANCIES OR INCONSISTENCIES.
LEVEL 1.5
LEVEL 1
LEVEL 1.5
LEVEL 1
96 GAL.
REC PR
35 GAL FOOD SCRAP CART
35 GAL.
96 GAL CART
96 GAL.
HOPPER W/
THRU-WALL OPENING
HOPPER
TRASH COLLECTION ROOM- LOOSE
LEVEL3-8
TRASH
96 GAL.
REC MC
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
3 FT
ACCESS
DOOR
FOOD
SCRAPS
35 GAL.
3 CY
WASTE
CONTAINER
96 GAL.
REC PR
CHUTE
MASTER
CONTROL
SERVICE OUTLETS. (TYP)
AIR COMPRESSORS
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
ELECTRIC
PALLET JACK
F.D.
B-3
B-2
B-1
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
ODOR CONTROL
WHEEL STOP 12"W x 5"H
WASTE
E
11TRASH COLLECTION ROOM- LOOSE
LEVEL 1
HOT/COLD
HOSE BIB
HOT/COLD
HOSE BIB
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
DRAWING TITLE
1150 - 1170 SAN ZENO W
SUNNYVALE, CA
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DATE
SCALE
DRAWING NO.
CONSULTANT
MAIN TRASH COLLECTION R
TR1
ARCHITECT
OWNER / DEVELOPER
NO. DATE ISSUE / REVISION
BDE - JONES
PROMETHIUS
SS
02/27/23
3/16" = 1' - 0"
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
CONSULTANT
BDE - JONES
TRASH STAGING AREA MAIN TRASH COLLECTION ROOM SECONDARY TRASH COLLECTION ROOM
PATH OF TRAVEL FROM TOWN HOUSES TO TRASH
COLLECTION ROOM
WASTE
FOOD
SCRAPS
35 GAL.
REC PR
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
REC MC
3 FT
ACCESS
DOOR
96 GAL.
REC PR
WASTE
30"Ø CHUTE
HOPPER
96 GAL.
REC PR
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-1 SECTION B-2
HOPPER
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-3
24"Ø CHUTE
LEVEL 2
WASTE
SHEET NOTES:
RESIDENTIAL TRASH TERMINATION ROOM
1. TRASH COLLECTION ROOM IS PART OF 2HR FIRE-RATED TRASH CHUTE SHAFT - RESTRICTED ACCESS.
2. FLOOR SHALL BE FINISHED WITH WATERPROOF DECK COATING. FLOOR TO HAVE MINIMAL SLOPE (1° MAX) AND FLOOR DRAIN. FLOOR LEVEL UNDER COMPACTOR.
3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIGH-GLOSS ENAMEL PAINT, 8'-0" AFF.
4. INSTALL WALL PROTECTION: 12"Wx5"H CONCRETE CURB AT BASE OF ALL NON-CONCRETE WALLS. DO NOT INSTALL THE CURB AROUND THE COMPACTORS/BISORTER OR POWER PACKS.
5. 10'-0" ROLL UP DOOR AND 3FT EXIT DOOR.
6. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/FT PER 2019 CBC.
7. (1) 30"Ø GRAVITY CHUTE FOR LOOSE WASTE & (2) 24"Ø GRAVITY CHUTES FOR PAPER & CONTAINER RECYCLING. CHUTES SHALL TERMINATE AT 5'-9" AFF.
8. MCP: CHUTE MASTER CONTROL PANEL SHALL BE WALL-MOUNTED 60" AFF. MUST ALLOW LOCK DOWN OF CHUTE INTAKES FOR EXCHANGING CONTAINERS AND WASHING CHUTES. REQUIRES 120V 15A DEDICATED SERVICE.
9. AC: 2HP CHUTE AIR COMPRESSOR SHALL BE MOUNTED72" AFF. REQUIRES 110V 15A SERVICE OUTLETS.
10. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. REQUIRES 120V 15A SERVICE OUTLETS.
11. HB: HOT AND COLD HOSE BIB SHALL BE WALL-MOUNTED 60" AFF.
12. PROVIDE ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. 4000lb CAPACITY; TURNING RADIUS: 45.5". REQUIRES 120V 15A SERVICE OUTLETS.
13. CHUTE DISCHARGE DOOR: TYPE-A, HORIZONTALLY INSULATED SLIDING-STEEL DOOR, HELD OPEN BY 165° F FUSIBLE LINK.
14. (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE.
CHUTE INTAKE VESTIBULES:
15. CHUTE INTAKE VESTIBULES SHALL BE 1HR FIRE-RATED WITH 1HR FIRE-RATED DOOR; 5'-0" MIN REQUIRED PER ADA STANDARDS - RESIDENTIAL ACCESS. PROVIDE (3) SELF CLOSING, 15x18 BOTTOM
HINGED, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING INTAKE DOORS TO DISPOSE TRASH AND RECYCLING PER CBC 713.13.1. POWER TO INTAKE DOORS SUPPLIED BY MCP. SEE DETAIL 1T2.0.
16. CHUTE SHAFT SHALL NOT BE ERECTED UNTIL CHUTE HAS BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, DOUBLE STUD-WALLS ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INTERIOR OF SHAFT SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES (BY OTHERS).
17. PROVIDE 18X18 SIDE HINGED, AUTOMATIC OPENING, ELECTRICALLY INTERLOCKED THRU-WALL INTAKE DOORS THAT DISPOSE INTO CONTAINERS PER CBC 713.13.1. SEE DETAILS 2/T2.0.
18. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND SQUARED FLOOR OPENINGS AT WOOD-FRAME CONSTRUCTION. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE CHUTE. SEE DETAIL 9/T2.0 FOR ANCHORING AND MASON BRA-RED SOUND ISOLATION PAD ASSEMBLY. POUR RINGS WILL VARY BASED ON THICKNESS OF FLOOR SLAB AND SHALL BE PROVIDED BY MANUFACTURER.
GENERAL NOTES:
1. ANY DESIGNS OR DESIGN SOLUTIONS PRESENTED IN THIS DRAWING OR SPECIFICATION, WHICH ARE
DIRECT OR IMPLIED, INCLUDING NARRATIVES, DRAWINGS, OR DIAGRAMS, ARE HEREBY CLARIFIED AS
EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS OR DESIGNS SUITABLE FOR CONSTRUCTION.
2. OMISSIONS FROM DRAWINGS OR SPECIFICATIONS, OR THE INACCURATE DESCRIPTION OF DETAILS OF
WORK, WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND
SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INACCURATELY DESCRIBED DETAILS OF THE WORK. WORK
SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ALL EXISTING FIELD CONDITIONS AND ANY DISCREPANCIES OR INCONSISTENCIES.
LEVEL 1.5
LEVEL 1
LEVEL 1.5
LEVEL 1
96 GAL.
REC PR
35 GAL FOOD SCRAP CART
35 GAL.
96 GAL CART
96 GAL.
HOPPER W/
THRU-WALL OPENING
HOPPER
TRASH COLLECTION ROOM- LOOSE
LEVEL3-8
TRASH
96 GAL.
REC MC
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
3 FT
ACCESS
DOOR
FOOD
SCRAPS
35 GAL.
3 CY
WASTE
CONTAINER
96 GAL.
REC PR
CHUTE
MASTER
CONTROL
SERVICE OUTLETS. (TYP)
AIR COMPRESSORS
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
ELECTRIC
PALLET JACK
F.D.
B-3
B-2
B-1
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
ODOR CONTROL
WHEEL STOP 12"W x 5"H
WASTE
E
11TRASH COLLECTION ROOM- LOOSE
LEVEL 1
HOT/COLD
HOSE BIB
HOT/COLD
HOSE BIB
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
DRAWING TITLE
1150 - 1170 SAN ZENO W
SUNNYVALE, CA
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DATE
SCALE
DRAWING NO.
CONSULTANT
MAIN TRASH COLLECTION R
TR1
ARCHITECT
OWNER / DEVELOPER
NO. DATE ISSUE / REVISION
BDE - JONES
PROMETHIUS
SS
02/27/23
WASTE
FOOD
SCRAPS
35 GAL.
REC PR
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
REC MC
3 FT
ACCESS
DOOR
96 GAL.
REC PR
WASTE
30"Ø CHUTE
HOPPER
96 GAL.
REC PR
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-1 SECTION B-2
HOPPER
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-3
24"Ø CHUTE
LEVEL 2
WASTE
SHEET NOTES:
RESIDENTIAL TRASH TERMINATION ROOM
1. TRASH COLLECTION ROOM IS PART OF 2HR FIRE-RATED TRASH CHUTE SHAFT - RESTRICTED ACCESS.
2. FLOOR SHALL BE FINISHED WITH WATERPROOF DECK COATING. FLOOR TO HAVE MINIMAL SLOPE (1° MAX) AND FLOOR DRAIN. FLOOR LEVEL UNDER COMPACTOR.
3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIGH-GLOSS ENAMEL PAINT, 8'-0" AFF.
4. INSTALL WALL PROTECTION: 12"Wx5"H CONCRETE CURB AT BASE OF ALL NON-CONCRETE WALLS. DO NOT INSTALL THE CURB AROUND THE COMPACTORS/BISORTER OR POWER PACKS.
5. 10'-0" ROLL UP DOOR AND 3FT EXIT DOOR.
6. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/FT PER 2019 CBC.
7. (1) 30"Ø GRAVITY CHUTE FOR LOOSE WASTE & (2) 24"Ø GRAVITY CHUTES FOR PAPER & CONTAINER RECYCLING. CHUTES SHALL TERMINATE AT 5'-9" AFF.
8. MCP: CHUTE MASTER CONTROL PANEL SHALL BE WALL-MOUNTED 60" AFF. MUST ALLOW LOCK DOWN OF CHUTE INTAKES FOR EXCHANGING CONTAINERS AND WASHING CHUTES. REQUIRES 120V 15A DEDICATED SERVICE.
9. AC: 2HP CHUTE AIR COMPRESSOR SHALL BE MOUNTED72" AFF. REQUIRES 110V 15A SERVICE OUTLETS.
10. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. REQUIRES 120V 15A SERVICE OUTLETS.
11. HB: HOT AND COLD HOSE BIB SHALL BE WALL-MOUNTED 60" AFF.
12. PROVIDE ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. 4000lb CAPACITY; TURNING RADIUS: 45.5". REQUIRES 120V 15A SERVICE OUTLETS.
13. CHUTE DISCHARGE DOOR: TYPE-A, HORIZONTALLY INSULATED SLIDING-STEEL DOOR, HELD OPEN BY 165° F FUSIBLE LINK.
14. (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE.
CHUTE INTAKE VESTIBULES:
15. CHUTE INTAKE VESTIBULES SHALL BE 1HR FIRE-RATED WITH 1HR FIRE-RATED DOOR; 5'-0" MIN REQUIRED PER ADA STANDARDS - RESIDENTIAL ACCESS. PROVIDE (3) SELF CLOSING, 15x18 BOTTOM
HINGED, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING INTAKE DOORS TO DISPOSE TRASH AND RECYCLING PER CBC 713.13.1. POWER TO INTAKE DOORS SUPPLIED BY MCP. SEE DETAIL 1T2.0.
16. CHUTE SHAFT SHALL NOT BE ERECTED UNTIL CHUTE HAS BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, DOUBLE STUD-WALLS ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INTERIOR OF SHAFT SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES (BY OTHERS).
17. PROVIDE 18X18 SIDE HINGED, AUTOMATIC OPENING, ELECTRICALLY INTERLOCKED THRU-WALL INTAKE DOORS THAT DISPOSE INTO CONTAINERS PER CBC 713.13.1. SEE DETAILS 2/T2.0.
18. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND SQUARED FLOOR OPENINGS AT WOOD-FRAME CONSTRUCTION. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE CHUTE. SEE DETAIL 9/T2.0 FOR ANCHORING AND MASON BRA-RED SOUND ISOLATION PAD ASSEMBLY. POUR RINGS WILL VARY BASED ON THICKNESS OF FLOOR SLAB AND SHALL BE PROVIDED BY MANUFACTURER.
GENERAL NOTES:
1. ANY DESIGNS OR DESIGN SOLUTIONS PRESENTED IN THIS DRAWING OR SPECIFICATION, WHICH ARE
DIRECT OR IMPLIED, INCLUDING NARRATIVES, DRAWINGS, OR DIAGRAMS, ARE HEREBY CLARIFIED AS
EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS OR DESIGNS SUITABLE FOR CONSTRUCTION.
2. OMISSIONS FROM DRAWINGS OR SPECIFICATIONS, OR THE INACCURATE DESCRIPTION OF DETAILS OF
WORK, WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND
SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INACCURATELY DESCRIBED DETAILS OF THE WORK. WORK
SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ALL EXISTING FIELD CONDITIONS AND ANY DISCREPANCIES OR INCONSISTENCIES.
LEVEL 1.5
LEVEL 1
LEVEL 1.5
LEVEL 1
96 GAL.
REC PR
35 GAL FOOD SCRAP CART
35 GAL.
96 GAL CART
96 GAL.
HOPPER W/
THRU-WALL OPENING
HOPPER
TRASH COLLECTION ROOM- LOOSE
LEVEL3-8
TRASH
96 GAL.
REC MC
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
3 FT
ACCESS
DOOR
FOOD
SCRAPS
35 GAL.
3 CY
WASTE
CONTAINER
96 GAL.
REC PR
CHUTE
MASTER
CONTROL
SERVICE OUTLETS. (TYP)
AIR COMPRESSORS
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
ELECTRIC
PALLET JACK
F.D.
B-3
B-2
B-1
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
ODOR CONTROL
WHEEL STOP 12"W x 5"H
WASTE
E
11TRASH COLLECTION ROOM- LOOSE
LEVEL 1
HOT/COLD
HOSE BIB
HOT/COLD
HOSE BIB
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
DRAWING TITLE
1150 - 1170 SAN ZENO W
SUNNYVALE, CA
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DRAWING NO.
CONSULTANT
MAIN TRASH COLLECTION R
TR1
ARCHITECT
OWNER / DEVELOPER
NO. DATE ISSUE / REVISION
BDE - JONES
PROMETHIUS
SS
15. LIGHTING TO BE MOTION-ACTIVATED.
16. 17.
18. 19.
ODOR CONTROL PROVIDED IN EACH TRASH DISPOSAL ROOM20.
TRASH EXHIBIT
MAIN TRASH COLLECTION ROOM
Attachment 5
135
LU SUBMITTAL 05 JULY 05, 2023
E
TRASH
D
5.2 3 CY
WASTE
CONTAINER
96 GAL.
REC MC
96 GAL.
REC PR
96 GAL.
REC MC
96 GAL.
REC PR
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
3 CY
CARDBOARD
CONTAINER
10'-0" ROLL-UP DOOR
96 GAL.
REC MC
96 GAL.
REC PR
3 FT
ACCESS
DOOR
HOT/COLD
HOSE BIB
SECONDARY TRASH COLLECTION ROOM- LOOSE
LEVEL 1
3 FT
ACCESS
DOOR
U-LINE
COLLAPSIBLE WIRE
CONTAINER
MODEL H-1731
FOOD
SCRAPS
35 GAL.
CHUTE MASTER CONTROL
120V 15A
SERVICE OUTLET. (TYP)
ODOR CONTROL
AIR COMPRESSOR
WHEEL STOP
12"W x 5"H
3 FT
ACCESS
DOOR
96 GAL.
REC PR
96 GAL.
REC MC
F.D.
3 FT
ACCESS
DOOR
U-LINE
COLLAPSIBLE WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
FOOD
SCRAPS
35 GAL.
REC
PR
REC
MC
W
CHUTE VESTIBULE
LEVEL 3-8
DRAWING TITLE
1150 - 1170 SAN ZENO WAY
SUNNYVALE, CA
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DATE
SCALE
DRAWING NO.
SECONDARY TRASH COLLECTION ROOM
TR1.1
NO. DATE ISSUED BYISSUE / REVISION
SS
02/27/23
1/4" = 1' - 0"
6. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/FT PER 2019 CBC.
7. (1) 30"Ø GRAVITY CHUTE FOR LOOSE WASTE & (2) 24"Ø GRAVITY CHUTES FOR PAPER & CONTAINER RECYCLING. CHUTES SHALL TERMINATE AT 5'-9" AFF.
8. MCP: CHUTE MASTER CONTROL PANEL SHALL BE WALL-MOUNTED 60" AFF. MUST ALLOW LOCK DOWN OF CHUTE INTAKES FOR EXCHANGING CONTAINERS AND WASHING CHUTES. REQUIRES 120V 15A DEDICATED SERVICE.
9. AC: 2HP CHUTE AIR COMPRESSOR SHALL BE MOUNTED72" AFF. REQUIRES 110V 15A SERVICE OUTLETS.
10. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. REQUIRES 120V 15A SERVICE OUTLETS.
11. HB: HOT AND COLD HOSE BIB SHALL BE WALL-MOUNTED 60" AFF.
12. PROVIDE ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. 4000lb CAPACITY; TURNING RADIUS: 45.5". REQUIRES 120V 15A SERVICE OUTLETS.
13. CHUTE DISCHARGE DOOR: TYPE-A, HORIZONTALLY INSULATED SLIDING-STEEL DOOR, HELD OPEN BY 165° F FUSIBLE LINK.
14. (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE.
CHUTE INTAKE VESTIBULES:
15. CHUTE INTAKE VESTIBULES SHALL BE 1HR FIRE-RATED WITH 1HR FIRE-RATED DOOR; 5'-0" MIN REQUIRED PER ADA STANDARDS - RESIDENTIAL ACCESS. PROVIDE (3) SELF CLOSING, 15x18 BOTTOM
HINGED, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING INTAKE DOORS TO DISPOSE TRASH AND RECYCLING INTO PER CBC 713.13.1. POWER TO INTAKE DOORS SUPPLIED BY MCP. SEE DETAIL 1T2.0.
16. CHUTE SHAFT SHALL NOT BE ERECTED UNTIL CHUTE HAS BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, DOUBLE STUD-WALLS ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INTERIOR OF SHAFT SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES (BY OTHERS).
17. PROVIDE 18X18 SIDE HINGED, AUTOMATIC OPENING, ELECTRICALLY INTERLOCKED THRU-WALL INTAKE DOORS THAT DISPOSE INTO CONTAINERS PER CBC 713.13.1. SEE DETAILS 2/T2.0.
18. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND SQUARED FLOOR OPENINGS AT WOOD-FRAME CONSTRUCTION. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE CHUTE. SEE DETAIL 9/T2.0 FOR ANCHORING AND MASON BRA-RED SOUND ISOLATION PAD ASSEMBLY. POUR RINGS WILL VARY BASED ON THICKNESS OF FLOOR SLAB AND SHALL BE PROVIDED BY MANUFACTURER.
GENERAL NOTES:
1. ANY DESIGNS OR DESIGN SOLUTIONS PRESENTED IN THIS DRAWING OR SPECIFICATION, WHICH ARE
DIRECT OR IMPLIED, INCLUDING NARRATIVES, DRAWINGS, OR DIAGRAMS, ARE HEREBY CLARIFIED AS
EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS OR DESIGNS SUITABLE FOR CONSTRUCTION.
2. OMISSIONS FROM DRAWINGS OR SPECIFICATIONS, OR THE INACCURATE DESCRIPTION OF DETAILS OF
WORK, WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND
SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INACCURATELY DESCRIBED DETAILS OF THE WORK. WORK
SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ALL EXISTING FIELD CONDITIONS AND ANY DISCREPANCIES OR INCONSISTENCIES.
E
TRASH
D
3 CY
WASTE
CONTAINER
96 GAL.
REC MC
96 GAL.
REC PR
96 GAL.
REC MC
96 GAL.
REC PR
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
3 CY
CARDBOARD
CONTAINER
10'-0" ROLL-UP DOOR
96 GAL.
REC MC
96 GAL.
REC PR
96 GAL.
REC MC
96 GAL.
REC PR
3 CY
WASTE
CONTAINER
SECTION C-1
3 FT
ACCESS
DOOR
HOT/COLD
HOSE BIB
SECONDARY TRASH COLLECTION ROOM- LOOSE
LEVEL 1
3 FT
ACCESS
DOOR
U-LINE
COLLAPSIBLE WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
FOOD
SCRAPS
35 GAL.
REC
PR
REC
MC
W
120V 15A
SERVICE OUTLET. (TYP)
CONTROL
AIR COMPRESSOR
WHEEL STOP
12"W x 5"H
3 FT
ACCESS
DOOR
CHUTE VESTIBULE
LEVEL 3-8
HOPPER W/
THRU-WALL
OPENING
96 GAL.
REC PR
96 GAL.
REC MC
F.D.
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
DRAWING TITLE
1150 - 1170 SAN ZENO WAY
SUNNYVALE, CA
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DATE
SCALE
DRAWING NO.
CONSULTANT
SECONDARY TRASH COLLECTION ROOM
TR1.1
ARCHITECT
OWNER / DEVELOPER
NO. DATE ISSUED BYISSUE / REVISION
BDE - JONES
PROMETHIUS
SS
02/27/23
1/4" = 1' - 0"
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
CONSULTANT
BDE - JONES
TRASH STAGING AREA MAIN TRASH COLLECTION ROOM SECONDARY TRASH COLLECTION ROOM
PATH OF TRAVEL FROM TOWN HOUSES TO TRASH
COLLECTION ROOM
WASTE
FOOD
SCRAPS
35 GAL.
REC PR
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
REC MC
3 FT
ACCESS
DOOR
96 GAL.
REC PR
WASTE
30"Ø CHUTE
HOPPER
96 GAL.
REC PR
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-1 SECTION B-2
HOPPER
18x18 SH AUTOMATIC OPENING
THRU-WALL INTAKE DOOR
SEE NOTE 17
SECTION B-3
24"Ø CHUTE
LEVEL 2
WASTE
SHEET NOTES:
RESIDENTIAL TRASH TERMINATION ROOM
1. TRASH COLLECTION ROOM IS PART OF 2HR FIRE-RATED TRASH CHUTE SHAFT - RESTRICTED ACCESS.
2. FLOOR SHALL BE FINISHED WITH WATERPROOF DECK COATING. FLOOR TO HAVE MINIMAL SLOPE (1° MAX) AND FLOOR DRAIN. FLOOR LEVEL UNDER COMPACTOR.
3. WALLS SHALL BE FINISHED WITH WASHABLE WATERPROOF SURFACE SUCH AS FRP OR HIGH-GLOSS ENAMEL PAINT, 8'-0" AFF.
4. INSTALL WALL PROTECTION: 12"Wx5"H CONCRETE CURB AT BASE OF ALL NON-CONCRETE WALLS. DO NOT INSTALL THE CURB AROUND THE COMPACTORS/BISORTER OR POWER PACKS.
5. 10'-0" ROLL UP DOOR AND 3FT EXIT DOOR.
6. ROOM SHALL BE MECHANICALLY VENTILATED WITH (1) CFM/FT PER 2019 CBC.
7. (1) 30"Ø GRAVITY CHUTE FOR LOOSE WASTE & (2) 24"Ø GRAVITY CHUTES FOR PAPER & CONTAINER RECYCLING. CHUTES SHALL TERMINATE AT 5'-9" AFF.
8. MCP: CHUTE MASTER CONTROL PANEL SHALL BE WALL-MOUNTED 60" AFF. MUST ALLOW LOCK DOWN OF CHUTE INTAKES FOR EXCHANGING CONTAINERS AND WASHING CHUTES. REQUIRES 120V 15A DEDICATED SERVICE.
9. AC: 2HP CHUTE AIR COMPRESSOR SHALL BE MOUNTED72" AFF. REQUIRES 110V 15A SERVICE OUTLETS.
10. OC: ODOR CONTROL UNIT SHALL BE WALL-MOUNTED 60" AFF. REQUIRES 120V 15A SERVICE OUTLETS.
11. HB: HOT AND COLD HOSE BIB SHALL BE WALL-MOUNTED 60" AFF.
12. PROVIDE ELECTRIC PALLET TRUCK FOR TRANSFERRING CONTAINERS. 4000lb CAPACITY; TURNING RADIUS: 45.5". REQUIRES 120V 15A SERVICE OUTLETS.
13. CHUTE DISCHARGE DOOR: TYPE-A, HORIZONTALLY INSULATED SLIDING-STEEL DOOR, HELD OPEN BY 165° F FUSIBLE LINK.
14. (1) UNDEDICATED 120V 15A SERVICE OUTLET REQUIRED FOR STAFF MAINTENANCE PURPOSE.
CHUTE INTAKE VESTIBULES:
15. CHUTE INTAKE VESTIBULES SHALL BE 1HR FIRE-RATED WITH 1HR FIRE-RATED DOOR; 5'-0" MIN REQUIRED PER ADA STANDARDS - RESIDENTIAL ACCESS. PROVIDE (3) SELF CLOSING, 15x18 BOTTOM
HINGED, ELECTRICALLY INTERLOCKED, AUTOMATIC OPENING INTAKE DOORS TO DISPOSE TRASH AND RECYCLING PER CBC 713.13.1. POWER TO INTAKE DOORS SUPPLIED BY MCP. SEE DETAIL 1T2.0.
16. CHUTE SHAFT SHALL NOT BE ERECTED UNTIL CHUTE HAS BEEN INSTALLED. FOR SOUND PROOFING PURPOSES, DOUBLE STUD-WALLS ARE REQUIRED ADJACENT TO OCCUPIED SPACES. INTERIOR OF SHAFT SHALL BE TAPED TO PREVENT ODOROUS AIR LEAKING INTO OCCUPIED SPACES (BY OTHERS).
17. PROVIDE 18X18 SIDE HINGED, AUTOMATIC OPENING, ELECTRICALLY INTERLOCKED THRU-WALL INTAKE DOORS THAT DISPOSE INTO CONTAINERS PER CBC 713.13.1. SEE DETAILS 2/T2.0.
18. PROVIDE ROUND FLOOR OPENINGS AT CONCRETE FLOORS AND SQUARED FLOOR OPENINGS AT WOOD-FRAME CONSTRUCTION. INSTALL FLOOR SUPPORT FRAME AT EACH FLOOR PENETRATION TO SECURE CHUTE. SEE DETAIL 9/T2.0 FOR ANCHORING AND MASON BRA-RED SOUND ISOLATION PAD ASSEMBLY. POUR
RINGS WILL VARY BASED ON THICKNESS OF FLOOR SLAB AND SHALL BE PROVIDED BY MANUFACTURER.
GENERAL NOTES:
1. ANY DESIGNS OR DESIGN SOLUTIONS PRESENTED IN THIS DRAWING OR SPECIFICATION, WHICH ARE
DIRECT OR IMPLIED, INCLUDING NARRATIVES, DRAWINGS, OR DIAGRAMS, ARE HEREBY CLARIFIED AS
EXAMPLES AND SHALL NOT BE CONSIDERED COMPLETE DESIGNS OR DESIGNS SUITABLE FOR CONSTRUCTION.
2. OMISSIONS FROM DRAWINGS OR SPECIFICATIONS, OR THE INACCURATE DESCRIPTION OF DETAILS OF
WORK, WHICH ARE MANIFESTLY NECESSARY TO CARRY OUT THE INTENT OF THE DRAWINGS AND
SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INACCURATELY DESCRIBED DETAILS OF THE WORK. WORK
SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ALL EXISTING FIELD CONDITIONS AND ANY DISCREPANCIES OR INCONSISTENCIES.
LEVEL 1.5
LEVEL 1
LEVEL 1.5
LEVEL 1
96 GAL.
REC PR
35 GAL FOOD SCRAP CART
35 GAL.
96 GAL CART
96 GAL.
HOPPER W/
THRU-WALL OPENING
HOPPER
TRASH COLLECTION ROOM- LOOSE
LEVEL3-8
TRASH
96 GAL.
REC MC
U-LINE
COLLAPSIBLE
WIRE
CONTAINER
MODEL H-1731
3412" HEIGHT
3 FT
ACCESS
DOOR
FOOD
SCRAPS
35 GAL.
3 CY
WASTE
CONTAINER
96 GAL.
REC PR
CHUTE
MASTER
CONTROL
SERVICE OUTLETS. (TYP)
AIR COMPRESSORS
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
3 CY
WASTE
CONTAINER
ELECTRIC
PALLET JACK
F.D.
B-3
B-2
B-1
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC PR
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
96 GAL.
REC MC
ODOR CONTROL
WHEEL STOP 12"W x 5"H
WASTE
E
11TRASH COLLECTION ROOM- LOOSE
LEVEL 1
HOT/COLD
HOSE BIB
HOT/COLD
HOSE BIB
AMERIC
1900 PO
EMERYV
P: 415.2
F: 415.2
SBROWN
DRAWING TITLE
11 PROJECT NO.
PROJECT
DRAWN
APPROVED
DATE
SCALE
CONSULTANT
MAIN
ARCHITECT
OWNER / DEVELOP
NO. DA
BDE -
PROME
02 3/16"
15. LIGHTING TO BE MOTION-ACTIVATED.
ODOR CONTROL PROVIDED IN EACH TRASH DISPOSAL ROOM
16. 17.
18. 19.
20. TRASH EXHIBIT
SECONDARY TRASH COLLECTION ROOM
Attachment 5
136
LU SUBMITTAL 05 JULY 05, 2023
6'-9"
3'-8"
1'
6'-9"
3'-8"
1'
6'-9"
1'
6'-9"
3'-8"
1'
6'-9"
3'-8"
1'
6'-9"
3'-8"
1' 6'-9"
3'-8"
WHEEL STOPS
12"W X 5"H
16'
16'-11
2"
COLLECTION AREA 1
19'-10"
6'-9"
4'-6" 1'
6'-9"
4'-6"
6'-9"
4'-6"1'
6'-9"
4'-6"
5'
10'
HOLD OPEN DOOR USING
CANE BOLT
HOLD OPEN DOOR
USING CANE BOLT
NEIGHBORING OFFICE AND
RESIDENTIAL TO BE BILLED
SEPARATELY. DESIGN BASED ON
CURRENT SITUATION
COLLECTION AREAS
SEPARATED BY
ENCLOSURE WALL
ENCLOSURE
USED FOR STAGING ONLY
(REDISTRICTED ACCESS
TO STAFF AND HAULER
ONLY)
3CY LOOSE
WASTE STAGED
CONTAINER
3CY LOOSE
WASTE STAGED
CONTAINER
3CY LOOSE
WASTE STAGED
CONTAINER
3CY LOOSE
WASTE STAGED
CONTAINER
3CY LOOSE
WASTE STAGED
CONTAINER
3CY LOOSE
WASTE STAGED
CONTAINER
3CY LOOSE
WASTE STAGED
CONTAINER
3'-8"
CENTRAL TRASH ENCLOSURE | EXISTING OFFICE BUILDINGS
FRONT-LOAD WASTE SERVICE
(7) LOOSE WASTE CONTAINERS STAGED 3X
WEEK, NOT DURING CART SERVICE DAYS
NOTES:
1. STRESS PAD MATERIAL: 5 INCH AGGREGATE BASE (CLASS II COMPACTED )WITH A 6 INCH PORTLAND CEMENT OVERLAY.
2. STAFF TO BE PRESENT AT THE TIME OF SERVICE TO ADJUST CONTAINERS OUT FOR STAGING. 6'-9"
3'-8"
WHEEL STOPS
12"W X 5"H
16'
16'-11
2" 19'-10"
6'-9"
4'-6" 1'
6'-9"
4'-6"
6'-9"
4'-6"1'
6'-9"
4'-6"
5'
10'
HOLD OPEN DOOR USING
CANE BOLT
HOLD OPEN DOOR
USING CANE BOLT
COLLECTION AREAS
SEPARATED BY
ENCLOSURE WALL
ENCLOSURE
USED FOR STAGING ONLY
(REDISTRICTED ACCESS
TO STAFF AND HAULER
ONLY)
NOTES:
1. STRESS PAD MATERIAL: 5 INCH AGGREGATE BASE (CLASS II COMPACTED )WITH A 6 INCH PORTLAND CEMENT OVERLAY.
2. STAFF TO BE PRESENT AT THE TIME OF SERVICE TO ADJUST CONTAINERS OUT FOR STAGING. 96 GAL.
REC
6"
96 GAL.
REC
6"
96 GAL.
REC
6"
96 GAL.
REC
96 GAL.
REC
6"
96 GAL.
REC
6"
96 GAL.
REC
6"
96 GAL.
REC
6"
96 GAL.
REC
6"
96 GAL.
REC
6"
96 GAL.
REC
6"
96 GAL.
REC
6"
96 GAL.
REC
6"
96 GAL.
REC
96 GAL.
REC
96 GAL.
REC
3CY LOOSE
CARDBOARD
STAGED CONTAINER
(16)
CARTS STAGED 2 x WEEK (RECYCLING 1
DAY, FOODSCRAPS 1 DAY) NOT DURING
WASTE SERVICE DAYS
CENTRAL TRASH ENCLOSURE | EXISTING OFFICE BUILDINGS
FRONT-LOAD CARDBOARD & SIDE-LOAD CART CONTAINER SERVICE
SPECIFICATIONS, OR WHICH ARE CUSTOMARILY PERFORMED, SHALL NOT RELIEVE THE CONTRACTOR FROM PERFORMING SUCH OMITTED OR INACCURATELY DESCRIBED DETAILS OF THE WORK. WORK
SHALL BE PERFORMED AS IF FULLY AND CORRECTLY SET FORTH AND DESCRIBED IN THE DRAWINGS AND SPECIFICATIONS.
3. CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO START OF CONSTRUCTION. THE ARCHITECT SHALL BE NOTIFIED IMMEDIATELY OF ALL EXISTING FIELD CONDITIONS AND ANY DISCREPANCIES OR INCONSISTENCIES.
AMERICAN TRASH MANAG
1900 POWELL STREET, SU
EMERYVILLE, CALIFORNIA
P: 415.292.5400
F: 415.292.5410
SBROWN@TRASHMANAGE
DRAWING TITLE
1150 - 1170 SA
SUNNYVA
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DATE
SCALE
CONSULTANT
TRASH STAGIN
ARCHITECT
OWNER / DEVELOPER
NO. DATE ISSU
BDE - JONES
PROMETHIUS
SS
02/27/23
1/32" = 1' - 0"CENTRAL TRASH ENCLOSURE |RESIDENTIAL BUILDING & EXISTING OFFICE BUILDINGS
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
CONSULTANT
BDE - JONES
TRASH STAGING AREA MAIN TRASH COLLECTION ROOM SECONDARY TRASH COLLECTION ROOM
PATH OF TRAVEL FROM TOWN HOUSES TO TRASH
COLLECTION ROOM
TRASH EXHIBIT
TRASH STAGING ENCLOSURE
COLLECTION AREA 2
COLLECTION AREA 1 COLLECTION AREA 2
NEIGHBORING OFFICE AND
RESIDENTIAL TO BE BILLED
SEPARATELY. DESIGN BASED ON
CURRENT SITUATION
Attachment 5
137
LU SUBMITTAL 05 JULY 05, 2023
Sunnyvale Front Load Truck-32.3 Sunnyvale Front Load Truck-32.3 6'-9"
3'-8"
1'
6'-9"
3'-8"
1'
6'-9"
1'
6'-9"
3'-8"
1'
6'-9"
3'-8"
1'
6'-9"
3'-8"
1' 6'-9"
3'-8"
16'
16'-11
2"
NEIGHBORING OFFICE
19'-10"
RESIDENTIAL
6'-9"
4'-6" 1'
6'-9"
4'-6"
6'-9"
4'-6"1'
6'-9"
4'-6"
5'
10'
3'-8"
DN
UP
UP
UP
UP
15 28'-7 5/8"3/8"29'-6"
3 BED TOWNHOME 2 BED TOWNHOME
TRASH
3 BED TOWNHOME 2 BED TOWNHOME
STAIR 4
ELEV 4 ELEV 3
MECHANICAL
ELEC
3 BED TOWNHOME 2 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME
7.28.18.29.110.111.112.112.313.113.216
2'-5 1/4"
16'-4
1/4"
14'-2
1/2" 21'-0" 15'-6" 21'-0" 21'-0" 25'-0"
21'-8
1/2"
13'-10
3/4"
25'-10
3/4" 21'-0"
245'-5 1/4"
SL
AL
SL
AL
Sunnyvale Front Load Truck-32.3
Sunnyvale Front Load Truck-32.3
x1
xA
F
G
J
115'-10"
xB
RAMP UP
28'-5"
27'-7"
3 BED TOWNHOME
3 BED TOWNHOME
PACKAGE ROOM
BOH
PARLOR
THE POST
OFFICE
STAIR 1
ELEV 1 & 2
90.00°
RESIDENTIAL
PARKING
R.R.
xC
H
x3
x4
x2
xA.1
28'-6"25'-7"4'-11"
25'-0"
25'-0"
17'-4 1/2"
11'-9"
56'-0"
73'-6"
xDEV
EV
EV
SL
AL
EV
EV
EV
SL
AL
Sunnyvale Front Load Truck-32.3
Sunnyvale Front Load Truck-32.3 Sunnyvale Front Load Truck-32.3
SOUTH PARCEL
2 ACRES
6'-9"
3'-8"
1'
6'-9"
3'-8"
1'
6'-9"
1'
6'-9"
3'-8"
1'
6'-9"
3'-8"
1'
6'-9"
3'-8"
1' 6'-9"
3'-8"
16'
16'-11
2"
NEIGHBORING OFFICE
19'-10"
RESIDENTIAL
6'-9"
4'-6" 1'
6'-9"
4'-6"
6'-9"
4'-6"1'
6'-9"
4'-6"
5'
10'
3'-8"
Sunnyvale Front Load Truck-32.3
DN
UP
UP
DN
DN
UP
UP
UP
x1
x7
xA
A
L
15 15
2.14567891014
B
E
F F
G G
J J
K K
12 115'-10"
60'-0"18'-0"
xB
RAMP UP
2'-5 1/4" 12'-0"
29'-11
1/4" 27'-6" 27'-6" 27'-6" 27'-6" 27'-6" 27'-6" 27'-6"
22'-0
3/4" 30'-2" 14'-4" 28'-7" 17'-6"
3'-6 1/4"
28'-7 5/8"
23'-4
3/8"29'-6"28'-6"30'-6"14'-6"
6'-4 1/4"
28'-5"
27'-7"
3 BED TOWNHOME 2 BED TOWNHOME
TRASH
3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME
TRASH
3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
THE SHOP
PACKAGE ROOM
BOH
PARLOR
THE POST
OFFICE
TRANSFORMER
1 24'-0"
DRIVE
AISLE
24'-0"
DRIVE AISLE
STAIR 2
STAIR 1
STAIR 3
STAIR 4
ELEV 4 ELEV 3
ELEV 1 & 2
164'-10
1/2"
90.00°
ELECTRICALUTILITY
RESIDENTIAL
PARKING
ELECTRICAL
ELECTRICAL
MECHANICAL
ELEC
ELEC
R.R.
C
13 3 BED TOWNHOME 2 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME xC
24'-0"
DRIVE
AISLE
211
D
H
x3
x4
x5
x6
3 x2
5.26.17.28.18.29.110.111.112.112.313.113.2
xA.1
28'-6"25'-7"4'-11"14'-6"
18'-0"
18'-8
1/2"
25'-0"
25'-0"
17'-4 1/2"
11'-9"
56'-0"
73'-6"
xD
70'-4"
16 16
2'-5 1/4"
16'-4
1/4"
14'-2
1/2" 21'-0" 15'-6" 21'-0" 21'-0" 25'-0"
21'-8
1/2"
13'-10
3/4"
25'-10
3/4" 21'-0"
26'-5
1/4"
245'-5 1/4"
349'-6 1/4"
70'-4"
AMERICAN TRASH MANAGEMEN
1900 POWELL STREET, SUITE 2
EMERYVILLE, CALIFORNIA 9460
P: 415.292.5400
F: 415.292.5410
[email protected]
DRAWING TITLE
1150 - 1170 SAN Z
SUNNYVALE,
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DATE
DRAWIN
CONSULTANT
TRASH PICKUP TRUCK
ARCHITECT
OWNER / DEVELOPER
NO. DATE ISSUE / REV
BDE - JONES
PROMETHIUS
SS
02/27/23
TRASH PICKUP TRUCK
ENTERING AND EXITING THE PROPERTY
STAGING LOCATION AND TURN STUDY
TRUCK DIMENSIONS
SCALE: 1/32" = 1' - 0"
SCALE: 1/32" = 1' - 0"
SCALE: 1/16" = 1' - 0"
Sunnyvale Front Load Truck-32.3 Sunnyvale Front Load Truck-32.3 DN
UP
UP
UP
UP
15 28'-7 5/8"3/8"29'-6"
3 BED TOWNHOME 2 BED TOWNHOME
TRASH
3 BED TOWNHOME 2 BED TOWNHOME
STAIR 4
ELEV 4 ELEV 3
MECHANICAL
ELEC
3 BED TOWNHOME 2 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME
7.28.18.29.110.111.112.112.313.113.216
2'-5 1/4"
16'-4
1/4"
14'-2
1/2" 21'-0" 15'-6" 21'-0" 21'-0" 25'-0"
21'-8
1/2"
13'-10
3/4"
25'-10
3/4" 21'-0"
SL
AL
SL
AL
Sunnyvale Front Load Truck-32.3
Sunnyvale Front Load Truck-32.3
x1
xA
F
G
J
115'-10"
xB
RAMP UP
28'-5"
27'-7"
3 BED TOWNHOME
3 BED TOWNHOME
PACKAGE ROOM
BOH
PARLOR
THE POST
OFFICE
STAIR 1
ELEV 1 & 2
90.00°
RESIDENTIAL
PARKING
R.R.
xC
H
x3
x4
x2
xA.1
28'-6"25'-7"4'-11"
25'-0"
25'-0"
17'-4 1/2"
11'-9"
56'-0"
73'-6"
xDEV
EV
EV
SL
AL
EV
EV
EV
SL
AL
Sunnyvale Front Load Truck-32.3
Sunnyvale Front Load Truck-32.3 Sunnyvale Front Load Truck-32.3
SOUTH PARCEL
2 ACRES
6'-9"
3'-8"
1'
6'-9"
3'-8"
1'
6'-9"
1'
6'-9"
3'-8"
1'
6'-9"
3'-8"
1'
6'-9"
3'-8"
1' 6'-9"
3'-8"
16'
16'-11
2"
NEIGHBORING OFFICE
19'-10"
RESIDENTIAL
6'-9"
4'-6" 1'
6'-9"
4'-6"
6'-9"
4'-6"1'
6'-9"
4'-6"
5'
10'
3'-8"
Sunnyvale Front Load Truck-32.3
DN
UP
UP
DN
DN
UP
UP
UP
x1
x7
xA
A
L
15 15
2.14567891014
B
E
F F
G G
J J
K K
12 115'-10"
60'-0"18'-0"
xB
RAMP UP
2'-5 1/4" 12'-0"
29'-11
1/4" 27'-6" 27'-6" 27'-6" 27'-6" 27'-6" 27'-6" 27'-6"
22'-0
3/4" 30'-2" 14'-4" 28'-7" 17'-6"
3'-6 1/4"
28'-7 5/8"
23'-4
3/8"29'-6"28'-6"30'-6"14'-6"
6'-4 1/4"
28'-5"
27'-7"
3 BED TOWNHOME 2 BED TOWNHOME
TRASH
3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME
TRASH
3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
THE SHOP
PACKAGE ROOM
BOH
PARLOR
THE POST
OFFICE
TRANSFORMER
1 24'-0"
DRIVE
AISLE
24'-0"
DRIVE AISLE
STAIR 2
STAIR 1
STAIR 3
STAIR 4
ELEV 4 ELEV 3
ELEV 1 & 2
164'-10
1/2"
90.00°
ELECTRICALUTILITY
RESIDENTIAL
PARKING
ELECTRICAL
ELECTRICAL
MECHANICAL
ELEC
ELEC
R.R.
C
13 3 BED TOWNHOME 2 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME xC
24'-0"
DRIVE
AISLE
211
D
H
x3
x4
x5
x6
3 x2
5.26.17.28.18.29.110.111.112.112.313.113.2
xA.1
28'-6"25'-7"4'-11"14'-6"
18'-0"
18'-8
1/2"
25'-0"
25'-0"
17'-4 1/2"
11'-9"
56'-0"
73'-6"
xD
70'-4"
16 16
2'-5 1/4"
16'-4
1/4"
14'-2
1/2" 21'-0" 15'-6" 21'-0" 21'-0" 25'-0"
21'-8
1/2"
13'-10
3/4"
25'-10
3/4" 21'-0"
26'-5
1/4"
245'-5 1/4"
349'-6 1/4"
70'-4"
EMERY
P: 415.
F: 415.
SBROW
DRAWING TITLE
1 PROJECT NO.
PROJECT
DRAWN
APPROVED
DATE
SCALE
CONSULTANT
TRA
ARCHITECT
OWNER / DEVEL
NO. D
BDE -
PROM
0 1/32
TRASH PICKUP TRUCK
ENTERING AND EXITING THE PROPERTY
STAGING LOCATION AND TURN STUDY
TRUCK DIMENSIONS
SCALE: 1/32" = 1' - 0"
SCALE: 1/32" = 1' - 0"
SCALE: 1/16" = 1' - 0"
ELEV 3
TRASH
58' 60'
60'
LOBBY
ELEV 4
3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 2 BED TOWNHOME2 BED TOWNHOME
STAIR CIRCULATION
CIRCULATION
1 2 3 4 5 6 7 8 9 10 11
3 BED TOWNHOME 2 BED TOWNHOME
ELEC
ELEV 1 & 2
59'
60'
57.6'
3 BED TOWNHOME
3 BED TOWNHOME
STAIR
CIRCULATION
RR
OFFICE
BOH
PACKAGE
LOBBY
MAIL
PARLOR
59.1'
18 19
20 21
ELEC
9' CLR
SL
AL
SL
AL
AMERICAN TRASH MANAGEMENT
1900 POWELL STREET, SUITE 220
EMERYVILLE, CALIFORNIA 94608
P: 415.292.5400
F: 415.292.5410
[email protected]
DRAWING TITLE
1150 - 1170 SAN ZENO WA
SUNNYVALE, CA
PROJECT NO.
PROJECT
PK
DRAWN
APPROVED
DATE
SCALE
DRAWING NO.
CONSULTANT
TRASH PICKUP TRUCK MANEU
TR2.
ARCHITECT
OWNER / DEVELOPER
NO. DATE ISSUE / REVISION
BDE - JONES
PROMETHIUS
SS
10/13/22
1/32" = 1' - 0"
TRASH PICKUP TRUCK
ENTERING AND EXITING THE PROPERTY
STAGING LOCATION AND TURN STUDY
TRUCK DIMENSIONS
SCALE: 1/32" = 1' - 0"
SCALE: 1/32" = 1' - 0"
SCALE: 1/16" = 1' - 0"
ELEV 3
TRASH
58' 60'
60'
LOBBY
ELEV 4
3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 2 BED TOWNHOME2 BED TOWNHOME
STAIR CIRCULATION
CIRCULATION
1 2 3 4 5 6 7 8 9 10 11
3 BED TOWNHOME 2 BED TOWNHOME
ELEC
ELEV 1 & 2
59'
60'
57.6'
3 BED TOWNHOME
3 BED TOWNHOME
STAIR
CIRCULATION
RR
OFFICE
BOH
PACKAGE
LOBBY
MAIL
PARLOR
59.1'
18 19
20 21
ELEC
9' CLR
SL
AL
SL
AL
TRASH PICKUP TRUCK
STAGING LOCATION AND TURN STUDY
TRUCK DIMENSIONS
SCALE: 1/32" = 1' - 0"
TRASH EXHIBIT
TRASH PICKUP TRUCK MANEUVER
Attachment 5
138
LU SUBMITTAL 05 JULY 05, 2023
GPR CHECKLIST
NEW HOME RATING SYSTEM, VERSION 8.2
94.5 Silver
Option 2: All Electric Compliance
0 %
Points
Targeted
Community
Energy
IAQ/Health
Resources
Water
CALGreen
Yes CALGreen (REQUIRED) 4 1 1 1 1
A. SITE
A2. Job Site Construction Waste Diversion
Yes A2.1 70% C&D Waste Diversion (Including Alternative Daily Cover) 2 2 A6. Stormwater Control: Prescriptive Path
Yes A6.2 Filtration and/or Bio-Retention Features 1 1 C. LANDSCAPE
35.31% Enter the landscape area percentage. Points capped at 3 for less than 15%.
Yes C1. Plants Grouped by Water Needs (Hydrozoning) 1 1 Yes C2. Three Inches of Mulch in Planting Beds 1 1
C3. Resource Efficient Landscapes
Yes C3.1 No Invasive Species According to Cal-IPC 1 1 Yes C3.2 Plants Chosen and Located to Grow to Natural Size 1 1 Yes C3.3 Drought Tolerant, Native, Mediterranean Species, or Other Appropriate Species 33
C4. Minimal Turf in Landscape
Yes C4.1 No Turf on Slopes Exceeding 10% and No Overhead Sprinklers Installed in Areas Less Than Eight Feet Wide 2 2
≤10% C4.2 Turf on a Small Percentage of Landscaped Area 2 2 Yes C7. One Inch of Compost in the Top Six to Twelve Inches of Soil 2 2 Yes C10. Submeter or Dedicated Meter for Landscape Irrigation 2 2 Yes C14. Large Stature Tree(s) 1 1
D3. Engineered Lumber
Yes D3.2 OSB for Subfloor 0.5 0.5
D9. Reduced Pollution Entering the Home from the Garage Yes D9.2 Mitigation Strategies for Attached Garage 1 1 D10. Structural Pest and Rot Controls
Yes D10.1 All Wood Located At Least 12 Inches Above the Soil 1 1 E. EXTERIOR
Yes E4. Durable and Non-Combustible Cladding Materials 1 1 E5. Durable Roofing Materials
N/A E5.2 Roofing Warranty for Shingle Roofing Y R R R R R F. INSULATION
F1. Insulation with 30% Post-Consumer or 60% Post-Industrial Recycled Content Yes F1.1 Walls and Floors 0.5 0.5
Yes F1.2 Ceilings 0.5 0.5
F2. Insulation that Meets the CDPH Standard Method—Residential for Low Emissions Yes F2.1 Walls and Floors 0.5 0.5
Yes F2.2 Ceilings 0.5 0.5
F3. Insulation That Does Not Contain Fire Retardants
Yes F3.1 Cavity Walls and Floors 1 1
Yes F3.2 Ceilings 1 1
G. PLUMBING
G2. Install Water-Efficient Fixtures
Yes G2.1 WaterSense Showerheads ≤ 1.8 gpm with Matching Compensation Valve 2 2
1.28 gpf G2.3 WaterSense Toilets with a Maximum Performance (MaP) Threshold of No Less Than 500 Grams ≤ 1.28 gpf OR ≤ 1.1 gpf 1 2
Yes G6. Submeter Water for Tenants 2 2
H1. Sealed Combustion Units
Yes H1.1 Sealed Combustion Furnace 1 1
Yes H1.2 Sealed Combustion Water Heater 2 2
H4. ENERGY STAR® Bathroom Fans
Yes H4.1 ENERGY STAR® Bathroom Fans Per HVI Standards 1 1 H6. Whole House Mechanical Ventilation Practices to Improve Indoor Air Quality Yes H6.1 Meet ASHRAE Standard 62.2-2016 Ventilation Residential Standards Y R R R R R Yes J4. All Electric or Combustion Appliance Safety Testing 1 1 J5. Building Energy Performance
Option 2: All Electric
Compliance J5.1 Home Outperforms Title 24 25.02 25+ Yes J6. Title 24 Prepared and Signed by a CABEC Certified Energy Analyst 1 1 K. FINISHES
K2. Low-VOC Interior Wall and Ceiling Paints
Yes K2.1 Zero-VOC Interior Wall and Ceiling Paints (< 5 gpl) 2 2 L. FLOORING
Yes L3. Durable Flooring 1 1
Yes M1. ENERGY STAR® Dishwasher 1 1
M2. Efficient Clothes Washing and Drying
Yes M2.2 ENERGY STAR® Dryer 1 1
<25 cubic feet M3. Size-Efficient ENERGY STAR® Refrigerator 1 2 Tier 2 Full Circuit M6. Electric Vehicle Charging Stations and Infrastructure 2 2 Yes M8. Gearless Elevator 1 1
N. COMMUNITY
N1. Smart Development
Yes N1.1 Infill Site 2 1 1
>35 N1.3 Conserve Resources by Increasing Density 4 2 2 N1.5 Home Size Efficiency 1 10
836 Enter the area of the home, in square feet 1 Enter the number of bedrooms
N2. Home(s)/Development Located Near Transit
Yes N2.2. Within 1/2 mile of a Major Transit Stop 2 2
M. APPLIANCES AND LIGHTING
D. STRUCTURAL FRAME AND BUILDING ENVELOPE
Blueprint Scoresh
San Zeno
Possible Points
H. HEATING, VENTILATION, AND AIR CONDITIONING
J. BUILDING PERFORMANCE AND TESTING
Points Targeted:
Certification Level Targeted:
Compliance Pathway Targeted:
T24 Compliance Targeted:
NEW HOME RATING SYSTEM, VERSION 8.2
94.5 Silver
Option 2: All Electric Compliance
0 %
Points
Targeted
Community
Energy
IAQ/Health
Resources
Water
CALGreen
Yes CALGreen (REQUIRED) 4 1 1 1 1
A. SITE
A2. Job Site Construction Waste Diversion
Yes A2.1 70% C&D Waste Diversion (Including Alternative Daily Cover) 2 2 A6. Stormwater Control: Prescriptive Path
Yes A6.2 Filtration and/or Bio-Retention Features 1 1 C. LANDSCAPE
35.31% Enter the landscape area percentage. Points capped at 3 for less than 15%.
Yes C1. Plants Grouped by Water Needs (Hydrozoning) 1 1 Yes C2. Three Inches of Mulch in Planting Beds 1 1
C3. Resource Efficient Landscapes
Yes C3.1 No Invasive Species According to Cal-IPC 1 1 Yes C3.2 Plants Chosen and Located to Grow to Natural Size 1 1 Yes C3.3 Drought Tolerant, Native, Mediterranean Species, or Other Appropriate Species 33
C4. Minimal Turf in Landscape
Yes C4.1 No Turf on Slopes Exceeding 10% and No Overhead Sprinklers Installed in Areas Less Than Eight Feet Wide 2 2
≤10% C4.2 Turf on a Small Percentage of Landscaped Area 2 2 Yes C7. One Inch of Compost in the Top Six to Twelve Inches of Soil 2 2 Yes C10. Submeter or Dedicated Meter for Landscape Irrigation 2 2 Yes C14. Large Stature Tree(s) 1 1
D3. Engineered Lumber
Yes D3.2 OSB for Subfloor 0.5 0.5
D9. Reduced Pollution Entering the Home from the Garage Yes D9.2 Mitigation Strategies for Attached Garage 1 1 D10. Structural Pest and Rot Controls
Yes D10.1 All Wood Located At Least 12 Inches Above the Soil 1 1 E. EXTERIOR
Yes E4. Durable and Non-Combustible Cladding Materials 1 1 E5. Durable Roofing Materials
N/A E5.2 Roofing Warranty for Shingle Roofing Y R R R R R F. INSULATION
F1. Insulation with 30% Post-Consumer or 60% Post-Industrial Recycled Content Yes F1.1 Walls and Floors 0.5 0.5
Yes F1.2 Ceilings 0.5 0.5
F2. Insulation that Meets the CDPH Standard Method—Residential for Low Emissions Yes F2.1 Walls and Floors 0.5 0.5
Yes F2.2 Ceilings 0.5 0.5
F3. Insulation That Does Not Contain Fire Retardants
Yes F3.1 Cavity Walls and Floors 1 1
Yes F3.2 Ceilings 1 1
G. PLUMBING
G2. Install Water-Efficient Fixtures
Yes G2.1 WaterSense Showerheads ≤ 1.8 gpm with Matching Compensation Valve 2 2
1.28 gpf G2.3 WaterSense Toilets with a Maximum Performance (MaP) Threshold of No Less Than 500 Grams ≤ 1.28 gpf OR ≤ 1.1 gpf 1 2
Yes G6. Submeter Water for Tenants 2 2
H1. Sealed Combustion Units
Yes H1.1 Sealed Combustion Furnace 1 1
Yes H1.2 Sealed Combustion Water Heater 2 2
H4. ENERGY STAR® Bathroom Fans
Yes H4.1 ENERGY STAR® Bathroom Fans Per HVI Standards 1 1 H6. Whole House Mechanical Ventilation Practices to Improve Indoor Air Quality Yes H6.1 Meet ASHRAE Standard 62.2-2016 Ventilation Residential Standards Y R R R R R Yes J4. All Electric or Combustion Appliance Safety Testing 1 1 J5. Building Energy Performance
Option 2: All Electric
Compliance J5.1 Home Outperforms Title 24 25.02 25+ Yes J6. Title 24 Prepared and Signed by a CABEC Certified Energy Analyst 1 1 K. FINISHES
K2. Low-VOC Interior Wall and Ceiling Paints
Yes K2.1 Zero-VOC Interior Wall and Ceiling Paints (< 5 gpl) 2 2 L. FLOORING
Yes L3. Durable Flooring 1 1
Yes M1. ENERGY STAR® Dishwasher 1 1
M2. Efficient Clothes Washing and Drying
Yes
M2.2 ENERGY STAR® Dryer 1 1
<25 cubic feet M3. Size-Efficient ENERGY STAR® Refrigerator 1 2 Tier 2 Full Circuit M6. Electric Vehicle Charging Stations and Infrastructure 2 2 Yes M8. Gearless Elevator 1 1
N. COMMUNITY
N1. Smart Development
Yes N1.1 Infill Site 2 1 1
>35 N1.3 Conserve Resources by Increasing Density 4 2 2 N1.5 Home Size Efficiency 1 10
836 Enter the area of the home, in square feet 1 Enter the number of bedrooms
N2. Home(s)/Development Located Near Transit
Yes N2.2. Within 1/2 mile of a Major Transit Stop 2 2
M. APPLIANCES AND LIGHTING
D. STRUCTURAL FRAME AND BUILDING ENVELOPE
Blueprint Scoresh
San Zeno
Possible Points
H. HEATING, VENTILATION, AND AIR CONDITIONING
J. BUILDING PERFORMANCE AND TESTING
Points Targeted:
Certification Level Targeted:
Compliance Pathway Targeted:
T24 Compliance Targeted:
N/A E5.2 Roofing Warranty for Shingle Roofing Y R R R R R F. INSULATION
F1. Insulation with 30% Post-Consumer or 60% Post-Industrial Recycled Content Yes F1.1 Walls and Floors 0.5 0.5
Yes F1.2 Ceilings 0.5 0.5
F2. Insulation that Meets the CDPH Standard Method—Residential for Low Emissions Yes F2.1 Walls and Floors 0.5 0.5
Yes F2.2 Ceilings 0.5 0.5
F3. Insulation That Does Not Contain Fire Retardants
Yes F3.1 Cavity Walls and Floors 1 1
Yes F3.2 Ceilings 1 1
G. PLUMBING
G2. Install Water-Efficient Fixtures
Yes G2.1 WaterSense Showerheads
≤ 1.8 gpm with Matching Compensation Valve 2 2
1.28 gpf G2.3 WaterSense Toilets with a Maximum Performance (MaP) Threshold of No Less Than 500 Grams ≤ 1.28 gpf OR ≤ 1.1 gpf 1 2
Yes G6. Submeter Water for Tenants 2 2
H1. Sealed Combustion Units
Yes H1.1 Sealed Combustion Furnace 1 1
Yes H1.2 Sealed Combustion Water Heater 2 2
H4. ENERGY STAR® Bathroom Fans
Yes H4.1 ENERGY STAR® Bathroom Fans Per HVI Standards 1 1 H6. Whole House Mechanical Ventilation Practices to Improve Indoor Air Quality Yes H6.1 Meet ASHRAE Standard 62.2-2016 Ventilation Residential Standards Y R R R R R Yes J4. All Electric or Combustion Appliance Safety Testing 1 1 J5. Building Energy Performance
Option 2: All Electric
Compliance J5.1 Home Outperforms Title 24 25.02 25+ Yes J6. Title 24 Prepared and Signed by a CABEC Certified Energy Analyst 1 1 K. FINISHES
K2. Low-VOC Interior Wall and Ceiling Paints
Yes K2.1 Zero-VOC Interior Wall and Ceiling Paints (< 5 gpl) 2 2 L. FLOORING
Yes L3. Durable Flooring 1 1
Yes M1. ENERGY STAR® Dishwasher 1 1
M2. Efficient Clothes Washing and Drying
Yes M2.2 ENERGY STAR® Dryer 1 1
<25 cubic feet M3. Size-Efficient ENERGY STAR® Refrigerator 1 2 Tier 2 Full Circuit M6. Electric Vehicle Charging Stations and Infrastructure 2 2 Yes M8. Gearless Elevator 1 1
N. COMMUNITY
N1. Smart Development
Yes N1.1 Infill Site 2 1 1
>35 N1.3 Conserve Resources by Increasing Density 4 2 2 N1.5 Home Size Efficiency 1 10
836 Enter the area of the home, in square feet 1 Enter the number of bedrooms
N2. Home(s)/Development Located Near Transit
Yes N2.2. Within 1/2 mile of a Major Transit Stop 2 2
N3. Pedestrian and Bicycle Access
N3.1 Pedestrian Access to Services Within 1/2 Mile of Community Services 1 2 4 Enter the number of Tier 1 services
5 Enter the number of Tier 2 services
Yes N3.5 Bicycle Storage for Residents 1 1
1 space per unit N3.7 Reduced Parking Capacity 2 2 N4. Outdoor Gathering Places
Yes N4.1 Public or Semi-Public Outdoor Gathering Places for Residents 1 1 N5. Social Interaction
Yes N5.2 Entrances Visible from Street and/or Other Front Doors 1 1 O. OTHER
Yes O1. GreenPoint Rated Checklist in Blueprints Y R R R R R Yes O2. Pre-Construction Kickoff Meeting with Rater and Subcontractors 2 0.5 1 0.5 Yes O7. Green Appraisal Addendum Y R R R R R
Summary Community Energy IAQ/Health Resources Water
Total Available Points in Specific Categories 404.5 47 135.5 73 91 58 Minimum Points Required in Specific Categories 50 2 25 6 6 6 Total Points Targeted 94.52 11 34.52 12 14.5 22.5
M. APPLIANCES AND LIGHTING
H. HEATING, VENTILATION, AND AIR CONDITIONING
J. BUILDING PERFORMANCE AND TESTING
NEW HOME RATING SYSTEM, VERSION 8.2
94.5 Silver
Option 2: All Electric Compliance
0 %
Points
Targeted
Community
Energy
IAQ/Health
Resources
Water
CALGreen (REQUIRED) 4 1 1 1 1
A2. Job Site Construction Waste Diversion
A2.1 70% C&D Waste Diversion (Including Alternative Daily Cover) 2 2 A6. Stormwater Control: Prescriptive Path
A6.2 Filtration and/or Bio-Retention Features 1 1
E
% Enter the landscape area percentage. Points capped at 3 for less than 15%.
C1. Plants Grouped by Water Needs (Hydrozoning) 1 1
C2. Three Inches of Mulch in Planting Beds 1 1
C3. Resource Efficient Landscapes
C3.1 No Invasive Species According to Cal-IPC 1 1
C3.2 Plants Chosen and Located to Grow to Natural Size 1 1 C3.3 Drought Tolerant, Native, Mediterranean Species, or O ther
Appropriate Species 33
C4. Minimal Turf in Landscape
C4.1 No Turf on Slopes Exceeding 10% and No Overhead Sprinklers Installed in Areas Less Than Eight Feet Wide 2 2
% C4.2 Turf on a Small Percentage of Landscaped Area 2 2 C7. One Inch of Compost in the Top Six to Twelve Inches of Soil 2 2 C10. Submeter or Dedicated Meter for Landscape Irrigation 2 2 C14. Large Stature Tree(s) 1 1
D3. Engineered Lumber
D3.2 OSB for Subfloor 0.5 0.5
D9. Reduced Pollution Entering the Home from the Garage D9.2 Mitigation Strategies for Attached Garage 1 1
D10. Structural Pest and Rot Controls
D10.1 All Wood Located At Least 12 Inches Above the Soil 1 1 E4. Durable and Non-Combustible Cladding Materials 1 1
E5. Durable Roofing Materials
E5.2 Roofing Warranty for Shingle Roofing Y R R R R R
F1. Insulation with 30% Post-Consumer or 60% Post-Industrial Recycled Content F1.1 Walls and Floors 0.5 0.5
F1.2 Ceilings 0.5 0.5
F2. Insulation that Meets the CDPH Standard Method—Residential for Low Emissions F2.1 Walls and Floors 0.5 0.5
F2.2 Ceilings 0.5 0.5
F3. Insulation That Does Not Contain Fire Retardants
F3.1 Cavity Walls and Floors 1 1
F3.2 Ceilings 1 1
G2. Install Water-Efficient Fixtures
G2.1 WaterSense Showerheads ≤ 1.8 gpm with Matching Compensation Valve 2 2 pf G2.3 WaterSense Toilets with a Maximum Performance (MaP) Threshold of No Less Than 500 Grams ≤ 1.28 gpf OR ≤ 1.1 gpf 1 2
G6. Submeter Water for Tenants 2 2
H1. Sealed Combustion Units
H1.1 Sealed Combustion Furnace 1 1
H1.2 Sealed Combustion Water Heater 2 2
H4. ENERGY STAR® Bathroom Fans
H4.1 ENERGY STAR® Bathroom Fans Per HVI Standards 1 1
H6. Whole House Mechanical Ventilation Practices to Improve Indoor Air Quality H6.1 Meet ASHRAE Standard 62.2-2016 Ventilation Residential Standards Y R R R R R J4. All Electric or Combustion Appliance Safety Testing 1 1 J5. Building Energy Performance
Electric
nce J5.1 Home Outperforms Title 24 25.02 25+
J6. Title 24 Prepared and Signed by a CABEC Certified Energy Analyst 1 1 K2. Low-VOC Interior Wall and Ceiling Paints
K2.1 Zero-VOC Interior Wall and Ceiling Paints (< 5 gpl) 2 2 L3. Durable Flooring 1 1
M1. ENERGY STAR® Dishwasher 1 1
M2. Efficient Clothes Washing and Drying
M2.2 ENERGY STAR® Dryer 1 1
c feet M3. Size-Efficient ENERGY STAR® Refrigerator 1 2 Circuit M6. Electric Vehicle Charging Stations and Infrastructure 2 2 M8. Gearless Elevator 1 1
Y
N1. Smart Development
N1.1 Infill Site 2 1 1
N1.3 Conserve Resources by Increasing Density 4 2 2
N1.5 Home Size Efficiency 1 10
Enter the area of the home, in square feet
Enter the number of bedrooms
N2. Home(s)/Development Located Near Transit
N2.2. Within 1/2 mile of a Major Transit Stop 2 2
S AND LIGHTING
AL FRAME AND BUILDING ENVELOPE
Blueprint Scoresh
eno
Possible Points
ENTILATION, AND AIR CONDITIONING
ERFORMANCE AND TESTING
Points Targeted:
Certification Level Targeted:
Compliance Pathway Targeted:
T24 Compliance Targeted:
NEW HOME RATING SYSTEM, VERSION 8.2
94.5 Silver
Option 2: All Electric Compliance
0 %
Points
Targeted
Community
Energy
IAQ/Health
Resources
Water
CALGreen
Yes CALGreen (REQUIRED) 4 1 1 1 1
A. SITE
A2. Job Site Construction Waste Diversion
Yes A2.1 70% C&D Waste Diversion (Including Alternative Daily Cover) 2 2 A6. Stormwater Control: Prescriptive Path
Yes A6.2 Filtration and/or Bio-Retention Features 1 1 C. LANDSCAPE
35.31% Enter the landscape area percentage. Points capped at 3 for less than 15%.
Yes C1. Plants Grouped by Water Needs (Hydrozoning) 1 1 Yes C2. Three Inches of Mulch in Planting Beds 1 1
C3. Resource Efficient Landscapes
Yes C3.1 No Invasive Species According to Cal-IPC 1 1 Yes C3.2 Plants Chosen and Located to Grow to Natural Size 1 1 Yes C3.3 Drought Tolerant, Native, Mediterranean Species, or Other Appropriate Species 33
C4. Minimal Turf in Landscape
Yes C4.1 No Turf on Slopes Exceeding 10% and No Overhead Sprinklers Installed in Areas Less Than Eight Feet Wide 2 2
≤10% C4.2 Turf on a Small Percentage of Landscaped Area 2 2 Yes C7. One Inch of Compost in the Top Six to Twelve Inches of Soil 2 2 Yes C10. Submeter or Dedicated Meter for Landscape Irrigation 2 2 Yes C14. Large Stature Tree(s) 1 1
D3. Engineered Lumber
Yes D3.2 OSB for Subfloor 0.5 0.5
D9. Reduced Pollution Entering the Home from the Garage Yes D9.2 Mitigation Strategies for Attached Garage 1 1 D10. Structural Pest and Rot Controls
Yes D10.1 All Wood Located At Least 12 Inches Above the Soil 1 1 E. EXTERIOR
Yes E4. Durable and Non-Combustible Cladding Materials 1 1 E5. Durable Roofing Materials
N/A E5.2 Roofing Warranty for Shingle Roofing Y R R R R R F. INSULATION
F1. Insulation with 30% Post-Consumer or 60% Post-Industrial Recycled Content Yes F1.1 Walls and Floors 0.5 0.5
Yes F1.2 Ceilings 0.5 0.5
F2. Insulation that Meets the CDPH Standard Method—Residential for Low Emissions Yes F2.1 Walls and Floors 0.5 0.5
Yes F2.2 Ceilings 0.5 0.5
F3. Insulation That Does Not Contain Fire Retardants
Yes F3.1 Cavity Walls and Floors 1 1
Yes F3.2 Ceilings 1 1
G. PLUMBING
G2. Install Water-Efficient Fixtures
Yes G2.1 WaterSense Showerheads ≤ 1.8 gpm with Matching Compensation Valve 2 2
1.28 gpf G2.3 WaterSense Toilets with a Maximum Performance (MaP) Threshold of No Less Than 500 Grams ≤ 1.28 gpf OR ≤ 1.1 gpf 1 2
Yes G6. Submeter Water for Tenants 2 2
H1. Sealed Combustion Units
Yes H1.1 Sealed Combustion Furnace 1 1
Yes H1.2 Sealed Combustion Water Heater 2 2
H4. ENERGY STAR® Bathroom Fans
Yes H4.1 ENERGY STAR® Bathroom Fans Per HVI Standards 1 1 H6. Whole House Mechanical Ventilation Practices to Improve Indoor Air Quality Yes H6.1 Meet ASHRAE Standard 62.2-2016 Ventilation Residential Standards Y R R R R R Yes J4. All Electric or Combustion Appliance Safety Testing 1 1 J5. Building Energy Performance
Option 2: All Electric
Compliance J5.1 Home Outperforms Title 24 25.02 25+ Yes J6. Title 24 Prepared and Signed by a CABEC Certified Energy Analyst 1 1 K. FINISHES
K2. Low-VOC Interior Wall and Ceiling Paints
Yes K2.1 Zero-VOC Interior Wall and Ceiling Paints (< 5 gpl) 2 2 L. FLOORING
Yes L3. Durable Flooring 1 1
Yes M1. ENERGY STAR® Dishwasher 1 1
M2. Efficient Clothes Washing and Drying
Yes
M2.2 ENERGY STAR® Dryer 1 1
<25 cubic feet M3. Size-Efficient ENERGY STAR® Refrigerator 1 2 Tier 2 Full Circuit M6. Electric Vehicle Charging Stations and Infrastructure 2 2 Yes M8. Gearless Elevator 1 1
N. COMMUNITY
N1. Smart Development
Yes N1.1 Infill Site 2 1 1
>35 N1.3 Conserve Resources by Increasing Density 4 2 2 N1.5 Home Size Efficiency 1 10
836 Enter the area of the home, in square feet 1 Enter the number of bedrooms
N2. Home(s)/Development Located Near Transit
Yes N2.2. Within 1/2 mile of a Major Transit Stop 2 2
M. APPLIANCES AND LIGHTING
D. STRUCTURAL FRAME AND BUILDING ENVELOPE
Blueprint Scoresh
San Zeno
Possible Points
H. HEATING, VENTILATION, AND AIR CONDITIONING
J. BUILDING PERFORMANCE AND TESTING
Points Targeted:
Certification Level Targeted:
Compliance Pathway Targeted:
T24 Compliance Targeted:
Attachment 5
139
LU SUBMITTAL 05 JULY 05, 2023
BB
BB
BB
BB
BB
BB
SS C O
SSCOSS C O
WM
FH
FDC
FH
WHARF
SAN ZENO WAY
BFP
CB
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
SAI
C1+P1
C1+P1C1+P1
C1+P1
0.73 0.42 0.29 0.25 0.28 0.39 0.60 0.99 1.58 2.17 2.50 2.31 1.79 1.17 0.73 0.48 0.36 0.31 0.36 0.49 0.75 1.22 1.90 2.45 2.59 2.24 1.58 0.98 0.65 0.50 0.50 0.62 0.90 1.32 1.80 2.22 2.24 1.85 1.36
2.29 2.39 1.99 1.44 0.92 0.59 0.41 0.34 0.36 0.46 0.64 0.89 1.14 1.37 1.52 1.44 1.19 0.96 0.71 0.52 0.41 0.37 0.41 0.54 0.76 1.04 1.32 1.61 1.69 1.50 1.24 0.97 0.72 0.58 0.55 0.63 0.78 0.94 1.09 1.24 1.26 1.11 0.95
1.35 1.40 1.24 1.04 0.82 0.60 0.45 0.37 0.35 0.40 0.47 0.55 0.62 0.66 0.70 0.67 0.61 0.55 0.47 0.40 0.35 0.34 0.37 0.43 0.52 0.62 0.70 0.78 0.81 0.78 0.73 0.65 0.57 0.49 0.45 0.45 0.47 0.50 0.51 0.53 0.54 0.51 0.48
0.60 0.62 0.59 0.56 0.49 0.42 0.35 0.30 0.26 0.25 0.24 0.25 0.25 0.24 0.25 0.24 0.23 0.22 0.22 0.21 0.20 0.20 0.21 0.23 0.25 0.27 0.28 0.29 0.30 0.31 0.31 0.31 0.29 0.27 0.25 0.23 0.22 0.19 0.18 0.17 0.17 0.17 0.17
2.63 2.59 2.55 2.62 2.50
2.05 1.38 0.88 0.56 0.37 0.25 0.18
0.17 0.18 0.15 0.14 0.14 0.15 0.18 0.22 0.28 0.37 0.51 0.70 1.00 1.43 1.99 2.46 2.63 2.56 2.56 2.64 2.50 2.08 1.55 1.12 0.82
0.55 0.38 0.30 0.24 0.20 0.18 0.17 0.17 0.18 0.21 0.25 0.31 0.40 0.56
0.84 1.17 1.65 2.18 2.56 2.63 2.55 2.59 2.64 2.40 1.91 1.38 1.00 0.74 0.57 0.47 0.40 0.37 0.37 0.40 0.46 0.55 0.68 0.87 1.12 1.46 1.87 2.21 2.47 2.62 2.65 2.61 2.49
2.22 1.76
1.23 0.81
0.53 0.37
C+P1
C+P1
C+P1
0.05 0.06 0.07
0.08 0.10 0.12
0.12 0.16 0.18
0.18 0.24 0.27
0.37 0.38 0.32
0.59 0.53 0.41
0.96 0.78 0.56
1.56 1.15 0.75
2.14 1.58 0.94
1.76 1.03
1.48 0.94
1.11 0.76 0.49
0.75 0.58 0.42
0.46 0.42 0.35
0.28 0.26
0.18 0.18 0.16
0.12 0.13 0.12
0.08 0.10 0.10
0.09 0.11
0.11 0.14 0.15
0.15 0.19 0.21
0.22 0.29 0.30
0.35 0.43 0.41
0.66 0.58 0.44
1.08 0.87 0.61
1.71 1.28 0.83
2.27 1.73 1.02
1.75 1.08
1.45 0.93 0.56
1.00 0.71 0.49
0.60 0.52 0.40
0.34 0.35 0.31
0.22 0.22
0.13 0.14 0.13
0.08 0.09 0.09
0.06 0.07 0.06
0.05 0.06 0.07 0.05
0.09 0.10 0.09 0.08
0.17 0.16 0.14
0.28 0.24 0.20
0.55 0.43 0.33 0.24
1.20 0.79 0.53 0.37 0.24
1.52 0.94 0.58 0.35
2.28 1.59 0.96 0.54 0.28
1.86 1.32 0.78 0.41
1.36 1.21 0.91 0.53 0.27
0.71 0.82 0.76 0.58 0.34
0.48 0.53 0.49 0.37 0.20
0.03 0.04
0.04 0.05
0.07 0.09
0.11 0.14
0.19 0.25
0.33 0.47
0.65 0.91
1.29 1.77
2.20 2.40
2.42 2.45
2.44 2.33
2.01 1.58
1.18 0.88
0.65 0.48
0.36 0.27
0.21 0.16
0.13 0.11
0.09 0.07
0.06 0.06
0.06 0.06
0.07 0.08
0.10 0.13
0.17 0.22
0.30 0.40
0.55 0.77
1.10 1.53
2.00 2.32
2.39 2.40
2.39 2.36
2.13 1.69
1.23 0.88
0.62 0.44
0.32 0.23
0.17 0.12
0.09 0.07
0.05 0.04
0.03 0.03
0.04 0.05
0.07 0.09
0.13 0.18
0.26 0.36
0.50 0.70
0.99 1.41
1.91 2.30
2.38 2.30
2.33 2.39
2.23 1.80
1.32 0.94
0.68 0.50
0.39 0.32
0.28 0.27
0.30 MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE
AA AAAD
AD AD
SSCO
WM
FH
RPDA
FDC
SAN ZENO WAY
(46' ROW)
BFP
BFP
BFP
LOW
C+P1
0.66 0.39 0.17
0.82 0.34 0.10
0.21 0.09 0.04
0.05 0.03
0.04 0.03
0.03 0.03
0.03 0.04 0.04
0.05 0.06 0.07
0.08 0.10 0.12
0.12 0.16 0.18
0.18 0.24 0.27
0.37 0.38 0.32
0.59 0.53 0.41
0.96 0.78 0.56
1.56 1.15 0.75
2.14 1.58 0.94
1.76 1.03
1.48 0.94
0.54 0.88
1.19 0.94
0.47 0.23
0.15 0.11
0.08 0.06
0.04 0.04
0.03 0.03
0.03 0.04
0.04 0.05
0.07 0.09
0.11 0.14
0.19 0.25
0.33 0.47
0.65 0.91
1.29 1.77
2.20 2.40
2.42 2.45
2.44 MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE
BB
BB
AA AA AA AA AA
BB
BB
BB
BB
ADAD AD AD
SS C O
SS C OSS C O
WM
FH
FH
RPDA
FDC
FH
WHARF
SAN ZENO WAY
(46' ROW)
BFP
BFP
BFP
CB
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
SAI
C1+P1
C1+P1C1+P1
C1+P1
0.73 0.42 0.29 0.25 0.28 0.39 0.60 0.99 1.58 2.17 2.50 2.31 1.79 1.17 0.73 0.48 0.36 0.31 0.36 0.49 0.75 1.22 1.90 2.45 2.59 2.24 1.58 0.98 0.65 0.50 0.50 0.62 0.90 1.32 1.80 2.22 2.24 1.85 1.36
2.29 2.39 1.99 1.44 0.92 0.59 0.41 0.34 0.36 0.46 0.64 0.89 1.14 1.37 1.52 1.44 1.19 0.96 0.71 0.52 0.41 0.37 0.41 0.54 0.76 1.04 1.32 1.61 1.69 1.50 1.24 0.97 0.72 0.58 0.55 0.63 0.78 0.94 1.09 1.24 1.26 1.11 0.95
1.35 1.40 1.24 1.04 0.82 0.60 0.45 0.37 0.35 0.40 0.47 0.55 0.62 0.66 0.70 0.67 0.61 0.55 0.47 0.40 0.35 0.34 0.37 0.43 0.52 0.62 0.70 0.78 0.81 0.78 0.73 0.65 0.57 0.49 0.45 0.45 0.47 0.50 0.51 0.53 0.54 0.51 0.48
0.60 0.62 0.59 0.56 0.49 0.42 0.35 0.30 0.26 0.25 0.24 0.25 0.25 0.24 0.25 0.24 0.23 0.22 0.22 0.21 0.20 0.20 0.21 0.23 0.25 0.27 0.28 0.29 0.30 0.31 0.31 0.31 0.29 0.27 0.25 0.23 0.22 0.19 0.18 0.17 0.17 0.17 0.17
2.63 2.59 2.55 2.62 2.50
2.05 1.38 0.88 0.56 0.37 0.25 0.18
0.17 0.18 0.15
0.14 0.14 0.15 0.18 0.22 0.28 0.37 0.51 0.70 1.00 1.43 1.99 2.46 2.63 2.56 2.56 2.64 2.50 2.08 1.55 1.12 0.82
0.55 0.38 0.30 0.24 0.20 0.18 0.17 0.17 0.18 0.21 0.25 0.31 0.40
0.56 0.84 1.17 1.65 2.18 2.56 2.63 2.55 2.59 2.64 2.40 1.91 1.38 1.00 0.74 0.57 0.47 0.40 0.37 0.37 0.40 0.46 0.55 0.68 0.87 1.12 1.46 1.87 2.21 2.47 2.62 2.65 2.61 2.49
2.22 1.76
1.23 0.81
0.53 0.37
C+P1
C+P1
C+P1
0.66 0.39 0.17
0.82 0.34 0.10
0.21 0.09 0.04
0.05 0.03
0.04 0.03
0.03 0.03
0.03 0.04 0.04
0.05 0.06 0.07
0.08 0.10 0.12
0.12 0.16 0.18
0.18 0.24 0.27
0.37 0.38 0.32
0.59 0.53 0.41
0.96 0.78 0.56
1.56 1.15 0.75
2.14 1.58 0.94
1.76 1.03
1.48 0.94
1.11 0.76 0.49
0.75 0.58 0.42
0.46 0.42 0.35
0.28 0.26
0.18 0.18 0.16
0.12 0.13 0.12
0.08 0.10 0.10
0.09 0.11
0.11 0.14 0.15
0.15 0.19 0.21
0.22 0.29 0.30
0.35 0.43 0.41
0.66 0.58 0.44
1.08 0.87 0.61
1.71 1.28 0.83
2.27 1.73 1.02
1.75 1.08
1.45 0.93 0.56
1.00 0.71 0.49
0.60 0.52 0.40
0.34 0.35 0.31
0.22 0.22
0.13 0.14 0.13
0.08 0.09 0.09
0.06 0.07 0.06
0.05 0.06 0.07 0.05
0.09 0.10 0.09 0.08
0.17 0.16 0.14
0.28 0.24 0.20
0.55 0.43 0.33 0.24
1.20 0.79 0.53 0.37 0.24
1.52 0.94 0.58 0.35
2.28 1.59 0.96 0.54 0.28
1.86 1.32 0.78 0.41
1.36 1.21 0.91 0.53 0.27
0.71 0.82 0.76 0.58 0.34
0.48 0.53 0.49 0.37 0.20
0.54 0.88
1.19 0.94
0.47 0.23
0.15 0.11
0.08 0.06
0.04 0.04
0.03 0.03
0.03 0.04
0.04 0.05
0.07 0.09
0.11 0.14
0.19 0.25
0.33 0.47
0.65 0.91
1.29 1.77
2.20 2.40
2.42 2.45
2.44 2.33
2.01 1.58
1.18 0.88
0.65 0.48
0.36 0.27
0.21 0.16
0.13 0.11
0.09 0.07
0.06 0.06
0.06 0.06
0.07 0.08
0.10 0.13
0.17 0.22
0.30 0.40
0.55 0.77
1.10 1.53
2.00 2.32
2.39 2.40
2.39 2.36
2.13 1.69
1.23 0.88
0.62 0.44
0.32 0.23
0.17 0.12
0.09 0.07
0.05 0.04
0.03 0.03
0.04 0.05
0.07 0.09
0.13 0.18
0.26 0.36
0.50 0.70
0.99 1.41
1.91 2.30
2.38 2.30
2.33 2.39
2.23 1.80
1.32 0.94
0.68 0.50
0.39 0.32
0.28 0.27
0.30 Luminaire Schedule - LED
Project: 170 SAN ZENO WAY - SUNNYVALE
Symbol Qty Label Arrangement LLF Luminaire Lumens Luminaire Watts Description 5 AA Single 0.900 2136 18 VISIONAIRE PRE-2-M-T2-16LC-3-3K - 15' POLE 6 BB Single 0.900 4171 35 VISIONAIRE PRE-2-L-T2-32LC-3-3K - 20' POLE Calculation Summary
Project: KIFER ROAD
Description CalcType Units Avg Max Min Avg/Min Max/Min
KIFER ROAD - PROJECT FRONTAGE Illuminance Fc 0.76 2.59 0.17 4.47 15.24 KIFER ROAD SIDEWALKS Illuminance Fc 1.21 2.65 0.14 8.64 18.93 Luminaire Schedule - LED
Project: SAN ZENO WAY
Label Symbol Qty ArrangementLLF Description
C+P1 3 GROUP0.950 LUMEC [MSC-002]-35W32LED4K-G3-LE3F @ 25' LC + 6' ARM + [MSC-C-001]-140L-450-NW-G1-2-UNV @ 14' LC + 2' ARM Luminaire Schedule - LED
Project: KIFER ROAD
Label Symbol Qty LLF Arrangement Description
C1+P1 4 0.950 GROUP LUMEC [MSC-002]-35W32LED4K-G3-LE2F @ 25' LC + 6' ARM + [MSC-C-001]-140L-450-NW-G1-2-UNV @ 14' LC + 2' ARM Calculation Summary
Project: SAN ZENO WAY
Description CalcType Units Avg Max Min Avg/Min Max/Min
SAN ZENO WAY Illuminance Fc 0.51 2.28 0.03 17.00 76.00
SAN ZENO WAY SIDEWALKS Illuminance Fc 0.76 2.45 0.03 25.33 81.67 AGI32 VERSION 20.1
AGI (C) 2021 LIGHTING ANALYSTS, INC.
10268 W. CENTENNIAL ROAD, SUITE 202
LITTLETON, CO 80127
* * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * SALES REPRESENTATIVE: ALR; KRISTIAN REYES
differences will occur between measured values and calculated values. lighting calculations. If the real environment conditions do not match the input data, dimensions, reflectances, furniture and architectural elements significantly affect the variations. Input data used to generate the attached calculations such as room measurement techniques and field conditions such as voltage and temperature tolerances in calculation methods, testing procedures, component performance, Some differences between measured values and calculated results may occur due to Calculations have been performed according to IES standards and good practice.
BY: APPLICATIONS ENGINEERING; RAMON ZAPATA
REPORT FOR: GIACALONE DESIGN SERVICES
PHONE: (510) 638-0158 - FAX (510) 638-2908
OAKLAND, CA 94621
P.O. BOX 2265
7777 PARDEE LANE
ASSOCIATED LIGHTING REPRESENTATIVES, INC
UES SHOWN ARE MAINTAINED HORIZONTAL FOOTCANDLES AT GRADE AMP, BALLAST, ELECTRICAL, AND SITE CHARACTERISTICS.
AMP, RATINGS, FIELD PERFORMANCE WILL DEPEND ON ACTUAL
S BASED ON ESTABLISHED IES PROCEDURES AND PUBLISHED
PHOTOMETRIC DATA USED AS INPUT FOR THESE CALCULATIONS
DATE REVSHEETSCALE
PROJECT DESCRIPTION
DRAWING NO. / INPUT FILE
170 SAN ZENO WAY
CITY OF SUNNYALE
21366REY-R4.DWG / 21366REY-R4.A32
BB
BB
SS C O
SSCO
WM
FH
FDC
ENO WAY
BFP
CB
LOW
LOW
LOW
LOW
LOW
LOW
LOW
SAI
C+P1
C+P1
C+P1
0.05 0.06 0.07
0.08 0.10 0.12
0.12 0.16 0.18
0.18 0.24 0.27
0.37 0.38 0.32
0.59 0.53 0.41
0.96 0.78 0.56
1.56 1.15 0.75
2.14 1.58 0.94
1.76 1.03
1.48 0.94
1.11 0.76 0.49
0.75 0.58 0.42
0.46 0.42 0.35
0.28 0.26
0.18 0.18 0.16
0.12 0.13 0.12
0.08 0.10 0.10
0.09 0.11
0.11 0.14 0.15
0.15 0.19 0.21
0.22 0.29 0.30
0.35 0.43 0.41
0.66 0.58 0.44
1.08 0.87 0.61
1.71 1.28 0.83
2.27 1.73 1.02
1.75 1.08
1.45 0.93 0.56
1.00 0.71 0.49
0.60 0.52 0.40
0.34 0.35 0.31
0.22 0.22
0.13 0.14 0.13
0.08 0.09 0.09
0.06 0.07 0.06
0.05 0.06 0.07 0.05
0.09 0.10 0.09 0.08
0.17 0.16 0.14
0.28 0.24 0.20
0.55 0.43 0.33 0.24
1.20 0.79 0.53 0.37 0.24
1.52 0.94 0.58 0.35
2.28 1.59 0.96 0.54 0.28
1.86 1.32 0.78 0.41
0.03 0.04
0.04 0.05
0.07 0.09
0.11 0.14
0.19 0.25
0.33 0.47
0.65 0.91
1.29 1.77
2.20 2.40
2.42 2.45
2.44 2.33
2.01 1.58
1.18 0.88
0.65 0.48
0.36 0.27
0.21 0.16
0.13 0.11
0.09 0.07
0.06 0.06
0.06 0.06
0.07 0.08
0.10 0.13
0.17 0.22
0.30 0.40
0.55 0.77
1.10 1.53
2.00 2.32
2.39 2.40
2.39 2.36
2.13 1.69
1.23 0.88
0.62 0.44
0.32 0.23
0.17 0.12
0.09 0.07
0.05 0.04
0.03 0.03
0.04 0.05
0.07 0.09
0.13 0.18
0.26 0.36
0.50 0.70
0.99 1.41
1.91 2.30
2.38 2.30
2.33 2.39
2.23 1.80
MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE
AA AAAD
AD AD
SSCO
WM
FH
RPDA
FDC
SAN ZENO WAY
(46' ROW)
BFP
BFP
BFP
LOW
C+P1
0.66 0.39 0.17
0.82 0.34 0.10
0.21 0.09 0.04
0.05 0.03
0.04 0.03
0.03 0.03
0.03 0.04 0.04
0.05 0.06 0.07
0.08 0.10 0.12
0.12 0.16 0.18
0.18 0.24 0.27
0.37 0.38 0.32
0.59 0.53 0.41
0.96 0.78 0.56
1.56 1.15 0.75
2.14 1.58 0.94
1.76 1.03
1.48 0.94
0.54 0.88
1.19 0.94
0.47 0.23
0.15 0.11
0.08 0.06
0.04 0.04
0.03 0.03
0.03 0.04
0.04 0.05
0.07 0.09
0.11 0.14
0.19 0.25
0.33 0.47
0.65 0.91
1.29 1.77
2.20 2.40
2.42 2.45
2.44 MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE
BB
BB
AA AA AA AA AA
BB
BB
BB
BB
ADAD AD AD
SS C O
SS C OSS C O
WM
FH
FH
RPDA
FDC
FH
WHARF
SAN ZENO WAY
(46' ROW)
BFP
BFP
BFP
CB
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
SAI
C1+P1
C1+P1C1+P1
C1+P1
0.73 0.42 0.29 0.25 0.28 0.39 0.60 0.99 1.58 2.17 2.50 2.31 1.79 1.17 0.73 0.48 0.36 0.31 0.36 0.49 0.75 1.22 1.90 2.45 2.59 2.24 1.58 0.98 0.65 0.50 0.50 0.62 0.90 1.32 1.80 2.22 2.24 1.85 1.36
2.29 2.39 1.99 1.44 0.92 0.59 0.41 0.34 0.36 0.46 0.64 0.89 1.14 1.37 1.52 1.44 1.19 0.96 0.71 0.52 0.41 0.37 0.41 0.54 0.76 1.04 1.32 1.61 1.69 1.50 1.24 0.97 0.72 0.58 0.55 0.63 0.78 0.94 1.09 1.24 1.26 1.11 0.95
1.35 1.40 1.24 1.04 0.82 0.60 0.45 0.37 0.35 0.40 0.47 0.55 0.62 0.66 0.70 0.67 0.61 0.55 0.47 0.40 0.35 0.34 0.37 0.43 0.52 0.62 0.70 0.78 0.81 0.78 0.73 0.65 0.57 0.49 0.45 0.45 0.47 0.50 0.51 0.53 0.54 0.51 0.48
0.60 0.62 0.59 0.56 0.49 0.42 0.35 0.30 0.26 0.25 0.24 0.25 0.25 0.24 0.25 0.24 0.23 0.22 0.22 0.21 0.20 0.20 0.21 0.23 0.25 0.27 0.28 0.29 0.30 0.31 0.31 0.31 0.29 0.27 0.25 0.23 0.22 0.19 0.18 0.17 0.17 0.17 0.17
2.63 2.59 2.55 2.62 2.50
2.05 1.38 0.88 0.56 0.37 0.25 0.18
0.17 0.18 0.15
0.14 0.14 0.15 0.18 0.22 0.28 0.37 0.51 0.70 1.00 1.43 1.99 2.46 2.63 2.56 2.56 2.64 2.50 2.08 1.55 1.12 0.82
0.55 0.38 0.30 0.24 0.20 0.18 0.17 0.17 0.18 0.21 0.25 0.31 0.40
0.56 0.84 1.17 1.65 2.18 2.56 2.63 2.55 2.59 2.64 2.40 1.91 1.38 1.00 0.74 0.57 0.47 0.40 0.37 0.37 0.40 0.46 0.55 0.68 0.87 1.12 1.46 1.87 2.21 2.47 2.62 2.65 2.61 2.49
2.22 1.76
1.23 0.81
0.53 0.37
C+P1
C+P1
C+P1
0.66 0.39 0.17
0.82 0.34 0.10
0.21 0.09 0.04
0.05 0.03
0.04 0.03
0.03 0.03
0.03 0.04 0.04
0.05 0.06 0.07
0.08 0.10 0.12
0.12 0.16 0.18
0.18 0.24 0.27
0.37 0.38 0.32
0.59 0.53 0.41
0.96 0.78 0.56
1.56 1.15 0.75
2.14 1.58 0.94
1.76 1.03
1.48 0.94
1.11 0.76 0.49
0.75 0.58 0.42
0.46 0.42 0.35
0.28 0.26
0.18 0.18 0.16
0.12 0.13 0.12
0.08 0.10 0.10
0.09 0.11
0.11 0.14 0.15
0.15 0.19 0.21
0.22 0.29 0.30
0.35 0.43 0.41
0.66 0.58 0.44
1.08 0.87 0.61
1.71 1.28 0.83
2.27 1.73 1.02
1.75 1.08
1.45 0.93 0.56
1.00 0.71 0.49
0.60 0.52 0.40
0.34 0.35 0.31
0.22 0.22
0.13 0.14 0.13
0.08 0.09 0.09
0.06 0.07 0.06
0.05 0.06 0.07 0.05
0.09 0.10 0.09 0.08
0.17 0.16 0.14
0.28 0.24 0.20
0.55 0.43 0.33 0.24
1.20 0.79 0.53 0.37 0.24
1.52 0.94 0.58 0.35
2.28 1.59 0.96 0.54 0.28
1.86 1.32 0.78 0.41
1.36 1.21 0.91 0.53 0.27
0.71 0.82 0.76 0.58 0.34
0.48 0.53 0.49 0.37 0.20
0.54 0.88
1.19 0.94
0.47 0.23
0.15 0.11
0.08 0.06
0.04 0.04
0.03 0.03
0.03 0.04
0.04 0.05
0.07 0.09
0.11 0.14
0.19 0.25
0.33 0.47
0.65 0.91
1.29 1.77
2.20 2.40
2.42 2.45
2.44 2.33
2.01 1.58
1.18 0.88
0.65 0.48
0.36 0.27
0.21 0.16
0.13 0.11
0.09 0.07
0.06 0.06
0.06 0.06
0.07 0.08
0.10 0.13
0.17 0.22
0.30 0.40
0.55 0.77
1.10 1.53
2.00 2.32
2.39 2.40
2.39 2.36
2.13 1.69
1.23 0.88
0.62 0.44
0.32 0.23
0.17 0.12
0.09 0.07
0.05 0.04
0.03 0.03
0.04 0.05
0.07 0.09
0.13 0.18
0.26 0.36
0.50 0.70
0.99 1.41
1.91 2.30
2.38 2.30
2.33 2.39
2.23 1.80
1.32 0.94
0.68 0.50
0.39 0.32
0.28 0.27
0.30 Luminaire Schedule - LED
Project: 170 SAN ZENO WAY - SUNNYVALE
Symbol Qty Label Arrangement LLF Luminaire Lumens Luminaire Watts Description 5 AA Single 0.900 2136 18 VISIONAIRE PRE-2-M-T2-16LC-3-3K - 15' POLE 6 BB Single 0.900 4171 35 VISIONAIRE PRE-2-L-T2-32LC-3-3K - 20' POLE SAN ZENO WAY SIDEWALKS Illuminance Fc 0.76 2.45 0.03 25.33 81.67 REPORT FOR: GIACALONE DESIGN SERVICES
PROJECT DESCRIPTION
170 SAN ZENO WAY
BB
BB
BB
SS C O
SSCOSS C O
WM
FH
BFP
CB
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
SAI
C1+P1
C1+P1C1+P1
0.39 0.60 0.99 1.58 2.17 2.50 2.31 1.79 1.17 0.73 0.48 0.36 0.31 0.36 0.49 0.75 1.22 1.90 2.45 2.59 2.24 1.58 0.98 0.65 0.50 0.50 0.62 0.90 1.32 1.80 2.22 2.24 1.85 1.36
0.46 0.64 0.89 1.14 1.37 1.52 1.44 1.19 0.96 0.71 0.52 0.41 0.37 0.41 0.54 0.76 1.04 1.32 1.61 1.69 1.50 1.24 0.97 0.72 0.58 0.55 0.63 0.78 0.94 1.09 1.24 1.26 1.11 0.95
0.40 0.47 0.55 0.62 0.66 0.70 0.67 0.61 0.55 0.47 0.40 0.35 0.34 0.37 0.43 0.52 0.62 0.70 0.78 0.81 0.78 0.73 0.65 0.57 0.49 0.45 0.45 0.47 0.50 0.51 0.53 0.54 0.51 0.48
0.25 0.24 0.25 0.25 0.24 0.25 0.24 0.23 0.22 0.22 0.21 0.20 0.20 0.21 0.23 0.25 0.27 0.28 0.29 0.30 0.31 0.31 0.31 0.29 0.27 0.25 0.23 0.22 0.19 0.18 0.17 0.17 0.17 0.17 2 0.28 0.37 0.51 0.70 1.00 1.43 1.99 2.46 2.63 2.56 2.56 2.64 2.50 2.08 1.55 1.12 0.82
0.55 0.38 0.30 0.24 0.20 0.18 0.17 0.17 0.18 0.21 0.25 0.31 0.40 0.56
0.84 1.17 1.65 2.18 2.56 2.63 2.55 2.59 2.64 2.40 1.91 1.38 1.00 0.74 0.57 0.47 0.40 0.37 0.37 0.40 0.46 0.55 0.68 0.87 1.12 1.46 1.87 2.21 2.47 2.62 2.65 2.61 2.49
2.22 1.76
1.23 0.81
0.53 0.37
C+P1
C+P1
C+P1
0.12 0.16 0.18
0.18 0.24 0.27
0.37 0.38 0.32
0.59 0.53 0.41
0.96 0.78 0.56
1.56 1.15 0.75
2.14 1.58 0.94
1.76 1.03
1.48 0.94
1.11 0.76 0.49
0.75 0.58 0.42
0.46 0.42 0.35
0.28 0.26
0.18 0.18 0.16
0.12 0.13 0.12
0.08 0.10 0.10
0.09 0.11
0.11 0.14 0.15
0.15 0.19 0.21
0.22 0.29 0.30
0.35 0.43 0.41
0.66 0.58 0.44
1.08 0.87 0.61
1.71 1.28 0.83
2.27 1.73 1.02
1.75 1.08
1.45 0.93 0.56
1.00 0.71 0.49
0.60 0.52 0.40
0.34 0.35 0.31
0.22 0.22
0.13 0.14 0.13
0.08 0.09 0.09
0.06 0.07 0.06
0.05 0.06 0.07 0.05
0.09 0.10 0.09 0.08
0.17 0.16 0.14
0.28 0.24 0.20
0.55 0.43 0.33 0.24
1.20 0.79 0.53 0.37 0.24
1.52 0.94 0.58 0.35
2.28 1.59 0.96 0.54 0.28
1.86 1.32 0.78 0.41
1.36 1.21 0.91 0.53 0.27
0.71 0.82 0.76 0.58 0.34
0.48 0.53 0.49 0.37 0.20
0.09 0.11
0.14 0.19
0.25 0.33
0.47 0.65
0.91 1.29
1.77 2.20
2.40 2.42
2.45 2.44
2.33 2.01
1.58 1.18
0.88 0.65
0.48 0.36
0.27 0.21
0.16 0.13
0.11 0.09
0.07 0.06
0.06 0.06
0.06 0.07
0.08 0.10
0.13 0.17
0.22 0.30
0.40 0.55
0.77 1.10
1.53 2.00
2.32 2.39
2.40 2.39
2.36 2.13
1.69 1.23
0.88 0.62
0.44 0.32
0.23 0.17
0.12 0.09
0.07 0.05
0.04 0.03
0.03 0.04
0.05 0.07
0.09 0.13
0.18 0.26
0.36 0.50
0.70 0.99
1.41 1.91
2.30 2.38
2.30 2.33
2.39 2.23
1.80 1.32
0.94 0.68
0.50 0.39
0.32 0.28
0.27 0.30
MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE
AA AAAD
AD AD
SSCO
WM
FH
RPDA
FDC
SAN ZENO WAY
(46' ROW)
BFP
BFP
BFP
LOW
C+P1
0.66 0.39 0.17
0.82 0.34 0.10
0.21 0.09 0.04
0.05 0.03
0.04 0.03
0.03 0.03
0.03 0.04 0.04
0.05 0.06 0.07
0.08 0.10 0.12
0.12 0.16 0.18
0.18 0.24 0.27
0.37 0.38 0.32
0.59 0.53 0.41
0.96 0.78 0.56
1.56 1.15 0.75
2.14 1.58 0.94
1.76 1.03
1.48 0.94
0.54 0.88
1.19 0.94
0.47 0.23
0.15 0.11
0.08 0.06
0.04 0.04
0.03 0.03
0.03 0.04
0.04 0.05
0.07 0.09
0.11 0.14
0.19 0.25
0.33 0.47
0.65 0.91
1.29 1.77
2.20 2.40
2.42 2.45
2.44 MATCHLINE MATCHLINE MATCHLINE MATCHLINE MATCHLINE
BB
BB
AA AA AA AA AA
BB
BB
BB
BB
ADAD AD AD
SS C O
SS C OSS C O
WM
FH
FH
RPDA
FDC
FH
WHARF
SAN ZENO WAY
(46' ROW)
BFP
BFP
BFP
CB
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
LOW
SAI
C1+P1
C1+P1C1+P1
C1+P1
0.73 0.42 0.29 0.25 0.28 0.39 0.60 0.99 1.58 2.17 2.50 2.31 1.79 1.17 0.73 0.48 0.36 0.31 0.36 0.49 0.75 1.22 1.90 2.45 2.59 2.24 1.58 0.98 0.65 0.50 0.50 0.62 0.90 1.32 1.80 2.22 2.24 1.85 1.36
2.29 2.39 1.99 1.44 0.92 0.59 0.41 0.34 0.36 0.46 0.64 0.89 1.14 1.37 1.52 1.44 1.19 0.96 0.71 0.52 0.41 0.37 0.41 0.54 0.76 1.04 1.32 1.61 1.69 1.50 1.24 0.97 0.72 0.58 0.55 0.63 0.78 0.94 1.09 1.24 1.26 1.11 0.95
1.35 1.40 1.24 1.04 0.82 0.60 0.45 0.37 0.35 0.40 0.47 0.55 0.62 0.66 0.70 0.67 0.61 0.55 0.47 0.40 0.35 0.34 0.37 0.43 0.52 0.62 0.70 0.78 0.81 0.78 0.73 0.65 0.57 0.49 0.45 0.45 0.47 0.50 0.51 0.53 0.54 0.51 0.48
0.60 0.62 0.59 0.56 0.49 0.42 0.35 0.30 0.26 0.25 0.24 0.25 0.25 0.24 0.25 0.24 0.23 0.22 0.22 0.21 0.20 0.20 0.21 0.23 0.25 0.27 0.28 0.29 0.30 0.31 0.31 0.31 0.29 0.27 0.25 0.23 0.22 0.19 0.18 0.17 0.17 0.17 0.17
2.63 2.59 2.55 2.62 2.50
2.05 1.38 0.88 0.56 0.37 0.25 0.18
0.17 0.18 0.15
0.14 0.14 0.15 0.18 0.22 0.28 0.37 0.51 0.70 1.00 1.43 1.99 2.46 2.63 2.56 2.56 2.64 2.50 2.08 1.55 1.12 0.82
0.55 0.38 0.30 0.24 0.20 0.18 0.17 0.17 0.18 0.21 0.25 0.31 0.40
0.56 0.84 1.17 1.65 2.18 2.56 2.63 2.55 2.59 2.64 2.40 1.91 1.38 1.00 0.74 0.57 0.47 0.40 0.37 0.37 0.40 0.46 0.55 0.68 0.87 1.12 1.46 1.87 2.21 2.47 2.62 2.65 2.61 2.49
2.22 1.76
1.23 0.81
0.53 0.37
C+P1
C+P1
C+P1
0.66 0.39 0.17
0.82 0.34 0.10
0.21 0.09 0.04
0.05 0.03
0.04 0.03
0.03 0.03
0.03 0.04 0.04
0.05 0.06 0.07
0.08 0.10 0.12
0.12 0.16 0.18
0.18 0.24 0.27
0.37 0.38 0.32
0.59 0.53 0.41
0.96 0.78 0.56
1.56 1.15 0.75
2.14 1.58 0.94
1.76 1.03
1.48 0.94
1.11 0.76 0.49
0.75 0.58 0.42
0.46 0.42 0.35
0.28 0.26
0.18 0.18 0.16
0.12 0.13 0.12
0.08 0.10 0.10
0.09 0.11
0.11 0.14 0.15
0.15 0.19 0.21
0.22 0.29 0.30
0.35 0.43 0.41
0.66 0.58 0.44
1.08 0.87 0.61
1.71 1.28 0.83
2.27 1.73 1.02
1.75 1.08
1.45 0.93 0.56
1.00 0.71 0.49
0.60 0.52 0.40
0.34 0.35 0.31
0.22 0.22
0.13 0.14 0.13
0.08 0.09 0.09
0.06 0.07 0.06
0.05 0.06 0.07 0.05
0.09 0.10 0.09 0.08
0.17 0.16 0.14
0.28 0.24 0.20
0.55 0.43 0.33 0.24
1.20 0.79 0.53 0.37 0.24
1.52 0.94 0.58 0.35
2.28 1.59 0.96 0.54 0.28
1.86 1.32 0.78 0.41
1.36 1.21 0.91 0.53 0.27
0.71 0.82 0.76 0.58 0.34
0.48 0.53 0.49 0.37 0.20
0.54 0.88
1.19 0.94
0.47 0.23
0.15 0.11
0.08 0.06
0.04 0.04
0.03 0.03
0.03 0.04
0.04 0.05
0.07 0.09
0.11 0.14
0.19 0.25
0.33 0.47
0.65 0.91
1.29 1.77
2.20 2.40
2.42 2.45
2.44 2.33
2.01 1.58
1.18 0.88
0.65 0.48
0.36 0.27
0.21 0.16
0.13 0.11
0.09 0.07
0.06 0.06
0.06 0.06
0.07 0.08
0.10 0.13
0.17 0.22
0.30 0.40
0.55 0.77
1.10 1.53
2.00 2.32
2.39 2.40
2.39 2.36
2.13 1.69
1.23 0.88
0.62 0.44
0.32 0.23
0.17 0.12
0.09 0.07
0.05 0.04
0.03 0.03
0.04 0.05
0.07 0.09
0.13 0.18
0.26 0.36
0.50 0.70
0.99 1.41
1.91 2.30
2.38 2.30
2.33 2.39
2.23 1.80
1.32 0.94
0.68 0.50
0.39 0.32
0.28 0.27
0.30 Luminaire Schedule - LED
Project: 170 SAN ZENO WAY - SUNNYVALE
Symbol Qty Label Arrangement LLF Luminaire LumensLuminaire WattsDescription 5 AA Single 0.900 2136 18 VISIONAIRE PRE-2-M-T2-16LC-3-3K - 15' POLE 6 BB Single 0.900 4171 35 VISIONAIRE PRE-2-L-T2-32LC-3-3K - 20' POLE Calculation Summary
Project: KIFER ROAD
Description CalcType Units Avg Max Min Avg/Min Max/Min
KIFER ROAD - PROJECT FRONTAGE Illuminance Fc 0.76 2.59 0.17 4.47 15.24 KIFER ROAD SIDEWALKS Illuminance Fc 1.21 2.65 0.14 8.64 18.93 Luminaire Schedule - LED
Project: SAN ZENO WAY
Label Symbol Qty ArrangementLLF Description
C+P1 3 GROUP0.950 LUMEC [MSC-002]-35W32LED4K-G3-LE3F @ 25' LC + 6' ARM + [MSC-C-001]-140L-450-NW-G1-2-UNV @ 14' LC + 2' ARM Project: KIFER ROAD
Label Symbol Qty LLF Arrangement Description
C1+P1 4 0.950 GROUP LUMEC [MSC-002]-35W32LED4K-G3-LE2F @ 25' LC + 6' ARM + [MSC-C-001]-140L-450-NW-G1-2-UNV @ 14' LC + 2' ARM Calculation Summary
Project: SAN ZENO WAY
Description CalcType Units Avg Max Min Avg/Min Max/Min
SAN ZENO WAY Illuminance Fc 0.51 2.28 0.03 17.00 76.00
SAN ZENO WAY SIDEWALKS Illuminance Fc 0.76 2.45 0.03 25.33 81.67 R.O.W. PHOTOMETRIC PLAN EXHIBIT
Attachment 5
140 L U SUBMITTAL 05 JULY 05, 2023
!
"#
"$
!
"# "$
%"#"$
&%#
'
"$
#
$
MECHANICAL EQUIPMENT HEIGHT
PARAPET
HEAT
PUMP
HEAT
PUMP
CORRIDOR
SUPPLY FAN
GARARGE
EXHAUST FAN
6FT MECHANICAL EQUIPMENT ABOVE PARAPET TO BE
PAINTED T
O MATCH PARAPET
9FT MECHANICAL EQUIPMENT ABOVE PARAPET TO BE SCREENED AS REQUIRED -
SUPPLEMENTARY STRUCTURAL FRAMING AS NEEDED
SOLAR PANELS - 5 KW PV SYSTEM SOLAR PANELS - 5 KW PV SYSTEM
ROOFTOP PUBLIC VIEW - LAWRENCE EXPY
ROOF PLAN LEGEND
ENLARGED ROOF PLAN - GARAGE EXHAUST FAN LOCA
TION
T.O. ROOF
T.O. PARAPET
ROOFTOP MECHANICAL UNIT BEYOND - GARAGE EXHAUST (9FT)
ROOFTOP MECHANICAL UNIT BEYOND - SUPPLY FAN (6FT)
T.O. ROOF
T.O.
PARAPET
SIGHT LINE EXHIBIT - LAWRENCE EXPY
Attachment 5
141 LU SUBMITTAL 05 JULY 05, 2023
%"#"$
''
#
'
"$%'
ROOFTOP MECHANICAL UNIT BEYOND - SUPPLY FAN (6FT)
ENLARGED ROOF PLAN - SUPPLY FAN
PARAPET
HEAT
PUMP
HEAT
PUMP
CORRIDOR
SUPPLY FAN 6FT MECHANICAL EQUIPMENT ABOVE PARAPET TO BE
PAINTED
TO MATCH PARAPET
SOLAR PANELS - 5 KW PV SYSTEM SOLAR PANELS - 5 KW PV SYSTEM
MECHANICAL EQUIPMENT HEIGHT ROOF PLAN LEGEND
ROOFTOP PUBLIC VIEW - SORONA CT
T.O. ROOF
T
.O. ROOF
T.O. PARAPET
T.O. PARAPET
SIGHT LINE EXHIBIT - SORONA CT
Attachment 5
142 LU SUBMITTAL 05 JULY 05, 2023
%"#"$
!
"#
"$
!
"#
"$
ROOFTOP MECHANICAL UNIT BEYOND - SUPPLY FAN (6FT)
ENLARGED ROOF PLAN - SUPPLY FAN
T.O. ROOF
T
.O. PARAPET
ROOF PLAN LEGEND
ROOFTOP PUBLIC VIEW - KIFER RD
MECHANICAL EQUIPMENT HEIGHT
PARAPET
HEAT
PUMP
HEAT
PUMP
CORRIDOR
SUPPLY FAN 6FT MECHANICAL EQUIPMENT ABOVE PARAPET TO BE
PAINTED
TO MATCH PARAPET
SOLAR PANELS - 5 KW PV SYSTEM SOLAR PANELS - 5 KW PV SYSTEM T.O. ROOF
T
.O. PARAPET
SIGHT LINE EXHIBIT - KIFER RD
Attachment 5
LU SUBMITTAL 05 JULY 05, 2023
THANK YOU
Attachment 5
Appendix B
Air Quality and Greenhouse Gas
Model Results
Attachment 5
1150-1170 Kifer Road
Bay Area AQMD Air District, Annual
Project Characteristics -
Land Use -
Construction Phase - Construction schedule provided by applicant.
Grading -
Demolition - Calculated 3,404 tons of asphalt removed based on size of existing parking: (400ft x 230 ft x 0.5ft) = 46,000 cubic feet --> multiplied by 148 lbs which is 1 cubic foot of asphalt, and then converted to tons.
Woodstoves - no wood stoves or fireplaces
Energy Use - Energy Use - 1 kBTU = 0.293014534 kWh -->
(5,226.68 KBTU) x (0.293014534 kWhr) = 1531.493202063 kWhr (Title-24) + 70.89 = 1602.38 and (3,155 KBTU) x (0.293014534 kWhr) = 912.740271917 kWhr (Nontitle-24) + 3,054.1 = 3,966.74 Mobile Land Use Mitigation - Incorporating project design features of site design/location features.
Construction Off-road Equipment Mitigation - Per BAAQMD requirements Mobile Land Use Mitigation - Density is 113 DU/Acre and 1 mile to downtwon, 0.14 miles to caltrain, 29% affordable units
1.1 Land Usage
Land Uses Size Metric Lot Acreage Floor Surface Area Population Apartments Mid Rise 225.00 Dwelling Unit 5.92 225,000.00 644 Enclosed Parking with Elevator 417.00 Space 3.75 166,800.00 0
1.2 Other Project Characteristics
Urbanization
Climate Zone
Urban
4 Wind Speed (m/s) Precipitation Freq (Days)2.2 64
1.3 User Entered Comments & Non-Default Data
1.0 Project Characteristics
Utility Company Pacific Gas and Electric Company
2027Operational Year
CO2 Intensity
(lb/MWhr)
203.98 0.033CH4 Intensity
(lb/MWhr)
0.004N2O Intensity
(lb/MWhr)
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 1 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
Table Name Column Name Default Value New Value
tblConstructionPhase NumDays 20.00 80.00
tblConstructionPhase NumDays 230.00 365.00
tblConstructionPhase NumDays 20.00 50.00
tblConstructionPhase NumDays 20.00 50.00
tblConstructionPhase NumDays 20.00 60.00
tblConstructionPhase NumDays 10.00 30.00
tblConstructionPhase NumDaysWeek 5.00 6.00
tblConstructionPhase NumDaysWeek 5.00 6.00
tblConstructionPhase NumDaysWeek 5.00 6.00
tblConstructionPhase NumDaysWeek 5.00 6.00
tblConstructionPhase NumDaysWeek 5.00 6.00
tblConstructionPhase NumDaysWeek 5.00 6.00
tblConstructionPhase PhaseEndDate 10/22/2026 8/10/2027
tblConstructionPhase PhaseEndDate 8/27/2026 2/27/2027
tblConstructionPhase PhaseEndDate 8/28/2025 9/27/2025
tblConstructionPhase PhaseEndDate 10/9/2025 12/29/2025
tblConstructionPhase PhaseEndDate 9/24/2026 5/8/2027
tblConstructionPhase PhaseEndDate 9/11/2025 10/31/2025
tblConstructionPhase PhaseStartDate 9/25/2026 5/9/2027
tblConstructionPhase PhaseStartDate 10/10/2025 12/30/2025 tblConstructionPhase PhaseStartDate 9/12/2025 11/1/2025 tblConstructionPhase PhaseStartDate 8/28/2026 2/28/2027 tblConstructionPhase PhaseStartDate 8/29/2025 9/27/2025 tblEnergyUse NT24E 3,054.10 3,966.74
tblEnergyUse NT24NG 3,155.00 0.00
tblEnergyUse T24E 70.89 1,602.38
tblEnergyUse T24NG 5,226.68 0.00
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 2 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
2.0 Emissions Summary
tblFireplaces FireplaceDayYear 11.14 0.00
tblFireplaces FireplaceHourDay 3.50 0.00
tblFireplaces FireplaceWoodMass 228.80 0.00
tblFireplaces NumberGas 33.75 0.00
tblFireplaces NumberNoFireplace 9.00 0.00
tblFireplaces NumberWood 38.25 0.00
tblWoodstoves NumberCatalytic 4.50 0.00
tblWoodstoves NumberNoncatalytic 4.50 0.00
tblWoodstoves WoodstoveDayYear 14.12 0.00
tblWoodstoves WoodstoveWoodMass 582.40 0.00
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 3 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
2.1 Overall Construction
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Year tons/yr MT/yr
2025 0.1321 1.2805 1.1640 2.5000e-
003
0.5214 0.0540 0.5754 0.2462 0.0499 0.2961 0.0000 220.5351 220.5351 0.0621 1.8700e- 003
222.6453
2026 0.2991 2.3496 3.2850 7.9500e-
003
0.3393 0.0859 0.4252 0.0915 0.0808 0.1723 0.0000 713.8253 713.8253 0.0934 0.0272 724.2613 2027 1.7047 0.6803 1.0686 2.1900e-
003
0.0723 0.0284 0.1007 0.0194 0.0266 0.0460 0.0000 195.2334 195.2334 0.0351 4.5400e- 003
197.4631
Maximum 1.7047 2.3496 3.2850 7.9500e-
003
0.5214 0.0859 0.5754 0.2462 0.0808 0.2961 0.0000 713.8253 713.8253 0.0934 0.0272 724.2613 Unmitigated Construction
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Year tons/yr MT/yr
2025 0.1321 1.2805 1.1640 2.5000e-
003
0.2418 0.0540 0.2958 0.1127 0.0499 0.1626 0.0000 220.5348 220.5348 0.0621 1.8700e- 003
222.6450
2026 0.2991 2.3496 3.2850 7.9500e-
003
0.3393 0.0859 0.4252 0.0915 0.0808 0.1723 0.0000 713.8248 713.8248 0.0934 0.0272 724.2609 2027 1.7047 0.6803 1.0686 2.1900e-
003
0.0723 0.0284 0.1007 0.0194 0.0266 0.0460 0.0000 195.2333 195.2333 0.0351 4.5400e- 003
197.4630
Maximum 1.7047 2.3496 3.2850 7.9500e-
003
0.3393 0.0859 0.4252 0.1127 0.0808 0.1723 0.0000 713.8248 713.8248 0.0934 0.0272 724.2609 Mitigated Construction
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 4 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio-CO2 Total CO2 CH4 N20 CO2e
Percent
Reduction
0.00 0.00 0.00 0.00 29.97 0.00 25.39 37.38 0.00 25.95 0.00 0.00 0.00 0.00 0.00 0.00 Quarter Start Date End Date Maximum Unmitigated ROG + NOX (tons/quarter) Maximum Mitigated ROG + NOX (tons/quarter) 1 8-1-2025 10-31-2025 0.9693 0.9693
2 11-1-2025 1-31-2026 0.6684 0.6684
3 2-1-2026 4-30-2026 0.6474 0.6474
4 5-1-2026 7-31-2026 0.6639 0.6639
5 8-1-2026 10-31-2026 0.6666 0.6666
6 11-1-2026 1-31-2027 0.6710 0.6710
7 2-1-2027 4-30-2027 0.4501 0.4501
8 5-1-2027 7-31-2027 1.5421 1.5421
9 8-1-2027 9-30-2027 0.1797 0.1797
Highest 1.5421 1.5421
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 5 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
2.2 Overall Operational
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Area 1.1019 0.0193 1.6729 9.0000e-
005
9.2700e-
003
9.2700e-
003
9.2700e-
003
9.2700e-
003
0.0000 2.7364 2.7364 2.6300e-
003
0.0000 2.8023
Energy 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 215.3276 215.3276 0.0348 4.2200e- 003
217.4568
Mobile 0.4293 0.4684 4.0058 8.4500e-
003
0.9906 6.0500e-
003
0.9967 0.2647 5.6400e-
003
0.2703 0.0000 780.0544 780.0544 0.0509 0.0379 792.6281
Waste 0.0000 0.0000 0.0000 0.0000 21.0096 0.0000 21.0096 1.2416 0.0000 52.0503 Water 0.0000 0.0000 0.0000 0.0000 4.6508 10.3322 14.9830 0.4794 0.0115 30.3885 Total 1.5311 0.4877 5.6787 8.5400e-
003
0.9906 0.0153 1.0060 0.2647 0.0149 0.2796 25.6604 1,008.450 6 1,034.111
0 1.8094 0.0536 1,095.325
9 Unmitigated Operational
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 6 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
2.2 Overall Operational
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Area 1.1019 0.0193 1.6729 9.0000e-
005
9.2700e-
003
9.2700e-
003
9.2700e-
003
9.2700e-
003
0.0000 2.7364 2.7364 2.6300e-
003
0.0000 2.8023
Energy 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 215.3276 215.3276 0.0348 4.2200e- 003
217.4568
Mobile 0.3196 0.2776 2.3983 3.9700e-
003
0.4484 3.1400e-
003
0.4515 0.1198 2.9200e-
003
0.1227 0.0000 366.7150 366.7150 0.0338 0.0226 374.2961
Waste 0.0000 0.0000 0.0000 0.0000 21.0096 0.0000 21.0096 1.2416 0.0000 52.0503 Water 0.0000 0.0000 0.0000 0.0000 4.6508 10.3322 14.9830 0.4794 0.0115 30.3885 Total 1.4215 0.2969 4.0712 4.0600e-
003
0.4484 0.0124 0.4608 0.1198 0.0122 0.1320 25.6604 595.1112 620.7716 1.7923 0.0383 676.9939 Mitigated Operational
3.0 Construction Detail
Construction Phase
Phase
Number
Phase Name Phase Type Start Date End Date Num Days
Week
Num Days Phase Description
1 Demolition Demolition 8/1/2025 9/27/2025 6 50
2 Site Preparation Site Preparation 9/27/2025 10/31/2025 6 30 3 Grading Grading 11/1/2025 12/29/2025 6 50
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio-CO2 Total CO2 CH4 N20 CO2e
Percent
Reduction
7.16 39.13 28.31 52.46 54.74 18.99 54.20 54.74 18.24 52.79 0.00 40.99 39.97 0.95 28.57 38.19 CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 7 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
4 Building Construction Building Construction 12/30/2025 2/27/2027 6 365 5 Paving Paving 2/28/2027 5/8/2027 6 60
6 Architectural Coating Architectural Coating 5/9/2027 8/10/2027 6 80 OffRoad Equipment
Phase Name Offroad Equipment Type Amount Usage Hours Horse Power Load Factor Architectural Coating Air Compressors 1 6.00 78 0.48
Demolition Concrete/Industrial Saws 1 8.00 81 0.73
Building Construction Cranes 1 7.00 231 0.29
Demolition Excavators 3 8.00 158 0.38
Grading Excavators 1 8.00 158 0.38
Building Construction Forklifts 3 8.00 89 0.20
Building Construction Generator Sets 1 8.00 84 0.74
Grading Graders 1 8.00 187 0.41
Paving Pavers 2 8.00 130 0.42
Paving Paving Equipment 2 8.00 132 0.36
Paving Rollers 2 8.00 80 0.38
Demolition Rubber Tired Dozers 2 8.00 247 0.40
Grading Rubber Tired Dozers 1 8.00 247 0.40
Site Preparation Rubber Tired Dozers 3 8.00 247 0.40
Building Construction Tractors/Loaders/Backhoes 3 7.00 97 0.37 Grading Tractors/Loaders/Backhoes 3 8.00 97 0.37
Site Preparation Tractors/Loaders/Backhoes 4 8.00 97 0.37 Residential Indoor: 455,625; Residential Outdoor: 151,875; Non-Residential Indoor: 0; Non-Residential Outdoor: 0; Striped Parking Area:
10,008 (Architectural Coating – sqft)
Acres of Grading (Site Preparation Phase): 45
Acres of Grading (Grading Phase): 50
Acres of Paving: 3.75
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 8 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.2 Demolition - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Fugitive Dust 0.0364 0.0000 0.0364 5.5100e-
003
0.0000 5.5100e-
003
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Off-Road 0.0523 0.4799 0.4855 9.7000e-
004
0.0213 0.0213 0.0198 0.0198 0.0000 84.9941 84.9941 0.0237 0.0000 85.5875 Total 0.0523 0.4799 0.4855 9.7000e-
004
0.0364 0.0213 0.0577 5.5100e-
003
0.0198 0.0253 0.0000 84.9941 84.9941 0.0237 0.0000 85.5875 Unmitigated Construction On-Site
3.1 Mitigation Measures Construction
Water Exposed Area
Building Construction Welders 1 8.00 46 0.45
Trips and VMT
Phase Name Offroad Equipment
Count
Worker Trip
Number
Vendor Trip
Number
Hauling Trip
Number
Worker Trip
Length
Vendor Trip
Length
Hauling Trip
Length
Worker Vehicle
Class
Vendor
Vehicle Class
Hauling
Vehicle Class
Demolition 6 15.00 0.00 337.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT Site Preparation 7 18.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT Grading 6 15.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT Building Construction 9 232.00 51.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT Paving 6 15.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT Architectural Coating 1 46.00 0.00 0.00 10.80 7.30 20.00 LD_Mix HDT_Mix HHDT CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 9 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.2 Demolition - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 3.5000e-
004
0.0227 5.4200e-
003
1.0000e-
004
2.8500e-
003
1.9000e-
004
3.0400e-
003
7.8000e-
004
1.8000e-
004
9.6000e-
004
0.0000 9.7115 9.7115 3.3000e-
004
1.5400e-
003
10.1785
Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Worker 8.4000e-
004
5.3000e-
004
7.2500e-
003
2.0000e-
005
2.9600e-
003
1.0000e-
005
2.9800e-
003
7.9000e-
004
1.0000e-
005
8.0000e-
004
0.0000 2.1451 2.1451 6.0000e-
005
6.0000e-
005
2.1631
Total 1.1900e-
003
0.0233 0.0127 1.2000e-
004
5.8100e-
003
2.0000e-
004
6.0200e-
003
1.5700e-
003
1.9000e-
004
1.7600e-
003
0.0000 11.8566 11.8566 3.9000e-
004
1.6000e-
003
12.3416
Unmitigated Construction Off-Site
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Fugitive Dust 0.0164 0.0000 0.0164 2.4800e-
003
0.0000 2.4800e-
003
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
Off-Road 0.0523 0.4799 0.4855 9.7000e-
004
0.0213 0.0213 0.0198 0.0198 0.0000 84.9940 84.9940 0.0237 0.0000 85.5874 Total 0.0523 0.4799 0.4855 9.7000e-
004
0.0164 0.0213 0.0377 2.4800e-
003
0.0198 0.0223 0.0000 84.9940 84.9940 0.0237 0.0000 85.5874 Mitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 10 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.2 Demolition - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 3.5000e-
004
0.0227 5.4200e-
003
1.0000e-
004
2.8500e-
003
1.9000e-
004
3.0400e-
003
7.8000e-
004
1.8000e-
004
9.6000e-
004
0.0000 9.7115 9.7115 3.3000e-
004
1.5400e-
003
10.1785
Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Worker 8.4000e-
004
5.3000e-
004
7.2500e-
003
2.0000e-
005
2.9600e-
003
1.0000e-
005
2.9800e-
003
7.9000e-
004
1.0000e-
005
8.0000e-
004
0.0000 2.1451 2.1451 6.0000e-
005
6.0000e-
005
2.1631
Total 1.1900e-
003
0.0233 0.0127 1.2000e-
004
5.8100e-
003
2.0000e-
004
6.0200e-
003
1.5700e-
003
1.9000e-
004
1.7600e-
003
0.0000 11.8566 11.8566 3.9000e-
004
1.6000e-
003
12.3416
Mitigated Construction Off-Site
3.3 Site Preparation - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Fugitive Dust 0.2949 0.0000 0.2949 0.1515 0.0000 0.1515 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Off-Road 0.0371 0.3785 0.2687 5.7000e-
004
0.0163 0.0163 0.0150 0.0150 0.0000 50.2005 50.2005 0.0162 0.0000 50.6064 Total 0.0371 0.3785 0.2687 5.7000e-
004
0.2949 0.0163 0.3112 0.1515 0.0150 0.1665 0.0000 50.2005 50.2005 0.0162 0.0000 50.6064 Unmitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 11 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.3 Site Preparation - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Worker 6.1000e-
004
3.8000e-
004
5.2200e-
003
2.0000e-
005
2.1300e-
003
1.0000e-
005
2.1400e-
003
5.7000e-
004
1.0000e-
005
5.8000e-
004
0.0000 1.5445 1.5445 4.0000e-
005
4.0000e-
005
1.5574
Total 6.1000e-
004
3.8000e-
004
5.2200e-
003
2.0000e-
005
2.1300e-
003
1.0000e-
005
2.1400e-
003
5.7000e-
004
1.0000e-
005
5.8000e-
004
0.0000 1.5445 1.5445 4.0000e-
005
4.0000e-
005
1.5574
Unmitigated Construction Off-Site
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Fugitive Dust 0.1327 0.0000 0.1327 0.0682 0.0000 0.0682 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Off-Road 0.0371 0.3785 0.2687 5.7000e-
004
0.0163 0.0163 0.0150 0.0150 0.0000 50.2004 50.2004 0.0162 0.0000 50.6063 Total 0.0371 0.3785 0.2687 5.7000e-
004
0.1327 0.0163 0.1490 0.0682 0.0150 0.0832 0.0000 50.2004 50.2004 0.0162 0.0000 50.6063 Mitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 12 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.3 Site Preparation - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Worker 6.1000e-
004
3.8000e-
004
5.2200e-
003
2.0000e-
005
2.1300e-
003
1.0000e-
005
2.1400e-
003
5.7000e-
004
1.0000e-
005
5.8000e-
004
0.0000 1.5445 1.5445 4.0000e-
005
4.0000e-
005
1.5574
Total 6.1000e-
004
3.8000e-
004
5.2200e-
003
2.0000e-
005
2.1300e-
003
1.0000e-
005
2.1400e-
003
5.7000e-
004
1.0000e-
005
5.8000e-
004
0.0000 1.5445 1.5445 4.0000e-
005
4.0000e-
005
1.5574
Mitigated Construction Off-Site
3.4 Grading - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Fugitive Dust 0.1771 0.0000 0.1771 0.0856 0.0000 0.0856 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Off-Road 0.0381 0.3829 0.3635 7.4000e-
004
0.0156 0.0156 0.0143 0.0143 0.0000 65.1745 65.1745 0.0211 0.0000 65.7015 Total 0.0381 0.3829 0.3635 7.4000e-
004
0.1771 0.0156 0.1927 0.0856 0.0143 0.1000 0.0000 65.1745 65.1745 0.0211 0.0000 65.7015 Unmitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 13 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.4 Grading - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Worker 8.4000e-
004
5.3000e-
004
7.2500e-
003
2.0000e-
005
2.9600e-
003
1.0000e-
005
2.9800e-
003
7.9000e-
004
1.0000e-
005
8.0000e-
004
0.0000 2.1451 2.1451 6.0000e-
005
6.0000e-
005
2.1631
Total 8.4000e-
004
5.3000e-
004
7.2500e-
003
2.0000e-
005
2.9600e-
003
1.0000e-
005
2.9800e-
003
7.9000e-
004
1.0000e-
005
8.0000e-
004
0.0000 2.1451 2.1451 6.0000e-
005
6.0000e-
005
2.1631
Unmitigated Construction Off-Site
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Fugitive Dust 0.0797 0.0000 0.0797 0.0385 0.0000 0.0385 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Off-Road 0.0381 0.3829 0.3635 7.4000e-
004
0.0156 0.0156 0.0143 0.0143 0.0000 65.1745 65.1745 0.0211 0.0000 65.7014 Total 0.0381 0.3829 0.3635 7.4000e-
004
0.0797 0.0156 0.0953 0.0385 0.0143 0.0529 0.0000 65.1745 65.1745 0.0211 0.0000 65.7014 Mitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 14 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.4 Grading - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Worker 8.4000e-
004
5.3000e-
004
7.2500e-
003
2.0000e-
005
2.9600e-
003
1.0000e-
005
2.9800e-
003
7.9000e-
004
1.0000e-
005
8.0000e-
004
0.0000 2.1451 2.1451 6.0000e-
005
6.0000e-
005
2.1631
Total 8.4000e-
004
5.3000e-
004
7.2500e-
003
2.0000e-
005
2.9600e-
003
1.0000e-
005
2.9800e-
003
7.9000e-
004
1.0000e-
005
8.0000e-
004
0.0000 2.1451 2.1451 6.0000e-
005
6.0000e-
005
2.1631
Mitigated Construction Off-Site
3.5 Building Construction - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Off-Road 1.3700e-
003
0.0125 0.0161 3.0000e-
005
5.3000e-
004
5.3000e-
004
5.0000e-
004
5.0000e-
004
0.0000 2.3192 2.3192 5.5000e-
004
0.0000 2.3328
Total 1.3700e-
003
0.0125 0.0161 3.0000e-
005
5.3000e-
004
5.3000e-
004
5.0000e-
004
5.0000e-
004
0.0000 2.3192 2.3192 5.5000e-
004
0.0000 2.3328
Unmitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 15 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.5 Building Construction - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 5.0000e-
005
2.2600e-
003
6.8000e-
004
1.0000e-
005
3.3000e-
004
1.0000e-
005
3.5000e-
004
1.0000e-
004
1.0000e-
005
1.1000e-
004
0.0000 0.9734 0.9734 2.0000e-
005
1.4000e-
004
1.0168
Worker 5.2000e-
004
3.3000e-
004
4.4800e-
003
1.0000e-
005
1.8300e-
003
1.0000e-
005
1.8400e-
003
4.9000e-
004
1.0000e-
005
5.0000e-
004
0.0000 1.3271 1.3271 3.0000e-
005
3.0000e-
005
1.3382
Total 5.7000e-
004
2.5900e-
003
5.1600e-
003
2.0000e-
005
2.1600e-
003
2.0000e-
005
2.1900e-
003
5.9000e-
004
2.0000e-
005
6.1000e-
004
0.0000 2.3005 2.3005 5.0000e-
005
1.7000e-
004
2.3550
Unmitigated Construction Off-Site
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Off-Road 1.3700e-
003
0.0125 0.0161 3.0000e-
005
5.3000e-
004
5.3000e-
004
5.0000e-
004
5.0000e-
004
0.0000 2.3192 2.3192 5.5000e-
004
0.0000 2.3328
Total 1.3700e-
003
0.0125 0.0161 3.0000e-
005
5.3000e-
004
5.3000e-
004
5.0000e-
004
5.0000e-
004
0.0000 2.3192 2.3192 5.5000e-
004
0.0000 2.3328
Mitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 16 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.5 Building Construction - 2025
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 5.0000e-
005
2.2600e-
003
6.8000e-
004
1.0000e-
005
3.3000e-
004
1.0000e-
005
3.5000e-
004
1.0000e-
004
1.0000e-
005
1.1000e-
004
0.0000 0.9734 0.9734 2.0000e-
005
1.4000e-
004
1.0168
Worker 5.2000e-
004
3.3000e-
004
4.4800e-
003
1.0000e-
005
1.8300e-
003
1.0000e-
005
1.8400e-
003
4.9000e-
004
1.0000e-
005
5.0000e-
004
0.0000 1.3271 1.3271 3.0000e-
005
3.0000e-
005
1.3382
Total 5.7000e-
004
2.5900e-
003
5.1600e-
003
2.0000e-
005
2.1600e-
003
2.0000e-
005
2.1900e-
003
5.9000e-
004
2.0000e-
005
6.1000e-
004
0.0000 2.3005 2.3005 5.0000e-
005
1.7000e-
004
2.3550
Mitigated Construction Off-Site
3.5 Building Construction - 2026
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Off-Road 0.2140 1.9515 2.5173 4.2200e-
003
0.0826 0.0826 0.0777 0.0777 0.0000 362.9539 362.9539 0.0853 0.0000 365.0869 Total 0.2140 1.9515 2.5173 4.2200e-
003
0.0826 0.0826 0.0777 0.0777 0.0000 362.9539 362.9539 0.0853 0.0000 365.0869 Unmitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 17 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.5 Building Construction - 2026
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 7.8800e-
003
0.3516 0.1053 1.5400e-
003
0.0524 2.0800e-
003
0.0545 0.0152 1.9900e-
003
0.0171 0.0000 149.5472 149.5472 3.1600e-
003
0.0221 156.2107
Worker 0.0772 0.0465 0.6625 2.2000e-
003
0.2869 1.2700e-
003
0.2882 0.0763 1.1700e-
003
0.0775 0.0000 201.3241 201.3241 4.8700e-
003
5.0900e-
003
202.9637
Total 0.0851 0.3981 0.7677 3.7400e-
003
0.3393 3.3500e-
003
0.3426 0.0915 3.1600e-
003
0.0946 0.0000 350.8713 350.8713 8.0300e-
003
0.0272 359.1744
Unmitigated Construction Off-Site
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Off-Road 0.2140 1.9515 2.5173 4.2200e-
003
0.0826 0.0826 0.0777 0.0777 0.0000 362.9535 362.9535 0.0853 0.0000 365.0865 Total 0.2140 1.9515 2.5173 4.2200e-
003
0.0826 0.0826 0.0777 0.0777 0.0000 362.9535 362.9535 0.0853 0.0000 365.0865 Mitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 18 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.5 Building Construction - 2026
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 7.8800e-
003
0.3516 0.1053 1.5400e-
003
0.0524 2.0800e-
003
0.0545 0.0152 1.9900e-
003
0.0171 0.0000 149.5472 149.5472 3.1600e-
003
0.0221 156.2107
Worker 0.0772 0.0465 0.6625 2.2000e-
003
0.2869 1.2700e-
003
0.2882 0.0763 1.1700e-
003
0.0775 0.0000 201.3241 201.3241 4.8700e-
003
5.0900e-
003
202.9637
Total 0.0851 0.3981 0.7677 3.7400e-
003
0.3393 3.3500e-
003
0.3426 0.0915 3.1600e-
003
0.0946 0.0000 350.8713 350.8713 8.0300e-
003
0.0272 359.1744
Mitigated Construction Off-Site
3.5 Building Construction - 2027
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Off-Road 0.0342 0.3117 0.4021 6.7000e-
004
0.0132 0.0132 0.0124 0.0124 0.0000 57.9799 57.9799 0.0136 0.0000 58.3206 Total 0.0342 0.3117 0.4021 6.7000e-
004
0.0132 0.0132 0.0124 0.0124 0.0000 57.9799 57.9799 0.0136 0.0000 58.3206 Unmitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 19 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.5 Building Construction - 2027
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 1.2300e-
003
0.0558 0.0166 2.4000e-
004
8.3700e-
003
3.3000e-
004
8.7000e-
003
2.4200e-
003
3.2000e-
004
2.7400e-
003
0.0000 23.4078 23.4078 5.0000e-
004
3.4600e-
003
24.4505
Worker 0.0117 6.8100e-
003
0.1005 3.4000e-
004
0.0458 1.9000e-
004
0.0460 0.0122 1.8000e-
004
0.0124 0.0000 31.2404 31.2404 7.1000e-
004
7.7000e-
004
31.4890
Total 0.0129 0.0626 0.1171 5.8000e-
004
0.0542 5.2000e-
004
0.0547 0.0146 5.0000e-
004
0.0151 0.0000 54.6482 54.6482 1.2100e-
003
4.2300e-
003
55.9395
Unmitigated Construction Off-Site
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Off-Road 0.0342 0.3117 0.4021 6.7000e-
004
0.0132 0.0132 0.0124 0.0124 0.0000 57.9798 57.9798 0.0136 0.0000 58.3205 Total 0.0342 0.3117 0.4021 6.7000e-
004
0.0132 0.0132 0.0124 0.0124 0.0000 57.9798 57.9798 0.0136 0.0000 58.3205 Mitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 20 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.5 Building Construction - 2027
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 1.2300e-
003
0.0558 0.0166 2.4000e-
004
8.3700e-
003
3.3000e-
004
8.7000e-
003
2.4200e-
003
3.2000e-
004
2.7400e-
003
0.0000 23.4078 23.4078 5.0000e-
004
3.4600e-
003
24.4505
Worker 0.0117 6.8100e-
003
0.1005 3.4000e-
004
0.0458 1.9000e-
004
0.0460 0.0122 1.8000e-
004
0.0124 0.0000 31.2404 31.2404 7.1000e-
004
7.7000e-
004
31.4890
Total 0.0129 0.0626 0.1171 5.8000e-
004
0.0542 5.2000e-
004
0.0547 0.0146 5.0000e-
004
0.0151 0.0000 54.6482 54.6482 1.2100e-
003
4.2300e-
003
55.9395
Mitigated Construction Off-Site
3.6 Paving - 2027
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Off-Road 0.0275 0.2575 0.4373 6.8000e-
004
0.0126 0.0126 0.0116 0.0116 0.0000 60.0578 60.0578 0.0194 0.0000 60.5434 Paving 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Total 0.0275 0.2575 0.4373 6.8000e-
004
0.0126 0.0126 0.0116 0.0116 0.0000 60.0578 60.0578 0.0194 0.0000 60.5434 Unmitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 21 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.6 Paving - 2027
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Worker 9.1000e-
004
5.3000e-
004
7.8000e-
003
3.0000e-
005
3.5600e-
003
1.0000e-
005
3.5700e-
003
9.5000e-
004
1.0000e-
005
9.6000e-
004
0.0000 2.4238 2.4238 6.0000e-
005
6.0000e-
005
2.4431
Total 9.1000e-
004
5.3000e-
004
7.8000e-
003
3.0000e-
005
3.5600e-
003
1.0000e-
005
3.5700e-
003
9.5000e-
004
1.0000e-
005
9.6000e-
004
0.0000 2.4238 2.4238 6.0000e-
005
6.0000e-
005
2.4431
Unmitigated Construction Off-Site
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Off-Road 0.0275 0.2575 0.4373 6.8000e-
004
0.0126 0.0126 0.0116 0.0116 0.0000 60.0577 60.0577 0.0194 0.0000 60.5433 Paving 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Total 0.0275 0.2575 0.4373 6.8000e-
004
0.0126 0.0126 0.0116 0.0116 0.0000 60.0577 60.0577 0.0194 0.0000 60.5433 Mitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 22 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.6 Paving - 2027
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Worker 9.1000e-
004
5.3000e-
004
7.8000e-
003
3.0000e-
005
3.5600e-
003
1.0000e-
005
3.5700e-
003
9.5000e-
004
1.0000e-
005
9.6000e-
004
0.0000 2.4238 2.4238 6.0000e-
005
6.0000e-
005
2.4431
Total 9.1000e-
004
5.3000e-
004
7.8000e-
003
3.0000e-
005
3.5600e-
003
1.0000e-
005
3.5700e-
003
9.5000e-
004
1.0000e-
005
9.6000e-
004
0.0000 2.4238 2.4238 6.0000e-
005
6.0000e-
005
2.4431
Mitigated Construction Off-Site
3.7 Architectural Coating - 2027
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Archit. Coating 1.6187 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Off-Road 6.8300e-
003
0.0458 0.0724 1.2000e-
004
2.0600e-
003
2.0600e-
003
2.0600e-
003
2.0600e-
003
0.0000 10.2130 10.2130 5.6000e-
004
0.0000 10.2269
Total 1.6255 0.0458 0.0724 1.2000e-
004
2.0600e-
003
2.0600e-
003
2.0600e-
003
2.0600e-
003
0.0000 10.2130 10.2130 5.6000e-
004
0.0000 10.2269
Unmitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 23 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.7 Architectural Coating - 2027
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Worker 3.7100e-
003
2.1600e-
003
0.0319 1.1000e-
004
0.0145 6.0000e-
005
0.0146 3.8700e-
003
6.0000e-
005
3.9200e-
003
0.0000 9.9108 9.9108 2.3000e-
004
2.5000e-
004
9.9896
Total 3.7100e-
003
2.1600e-
003
0.0319 1.1000e-
004
0.0145 6.0000e-
005
0.0146 3.8700e-
003
6.0000e-
005
3.9200e-
003
0.0000 9.9108 9.9108 2.3000e-
004
2.5000e-
004
9.9896
Unmitigated Construction Off-Site
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Archit. Coating 1.6187 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Off-Road 6.8300e-
003
0.0458 0.0724 1.2000e-
004
2.0600e-
003
2.0600e-
003
2.0600e-
003
2.0600e-
003
0.0000 10.2130 10.2130 5.6000e-
004
0.0000 10.2269
Total 1.6255 0.0458 0.0724 1.2000e-
004
2.0600e-
003
2.0600e-
003
2.0600e-
003
2.0600e-
003
0.0000 10.2130 10.2130 5.6000e-
004
0.0000 10.2269
Mitigated Construction On-Site
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 24 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
3.7 Architectural Coating - 2027
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Hauling 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Vendor 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Worker 3.7100e-
003
2.1600e-
003
0.0319 1.1000e-
004
0.0145 6.0000e-
005
0.0146 3.8700e-
003
6.0000e-
005
3.9200e-
003
0.0000 9.9108 9.9108 2.3000e-
004
2.5000e-
004
9.9896
Total 3.7100e-
003
2.1600e-
003
0.0319 1.1000e-
004
0.0145 6.0000e-
005
0.0146 3.8700e-
003
6.0000e-
005
3.9200e-
003
0.0000 9.9108 9.9108 2.3000e-
004
2.5000e-
004
9.9896
Mitigated Construction Off-Site
4.0 Operational Detail - Mobile
4.1 Mitigation Measures Mobile
Increase Density
Improve Destination Accessibility
Increase Transit Accessibility
Integrate Below Market Rate Housing
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 25 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Mitigated 0.3196 0.2776 2.3983 3.9700e-
003
0.4484 3.1400e-
003
0.4515 0.1198 2.9200e-
003
0.1227 0.0000 366.7150 366.7150 0.0338 0.0226 374.2961
Unmitigated 0.4293 0.4684 4.0058 8.4500e-
003
0.9906 6.0500e-
003
0.9967 0.2647 5.6400e-
003
0.2703 0.0000 780.0544 780.0544 0.0509 0.0379 792.6281
4.2 Trip Summary Information
4.3 Trip Type Information
Average Daily Trip Rate Unmitigated Mitigated
Land Use Weekday Saturday Sunday Annual VMT Annual VMT
Apartments Mid Rise 1,224.00 1,104.75 920.25 2,687,393 1,216,311 Enclosed Parking with Elevator 0.00 0.00 0.00
Total 1,224.00 1,104.75 920.25 2,687,393 1,216,311
Miles Trip % Trip Purpose %
Land Use H-W or C-W H-S or C-C H-O or C-NW H-W or C-W H-S or C-C H-O or C-NW Primary Diverted Pass-by Apartments Mid Rise 10.80 4.80 5.70 31.00 15.00 54.00 86 11 3 Enclosed Parking with Elevator 9.50 7.30 7.30 0.00 0.00 0.00 0 0 0
4.4 Fleet Mix
Land Use LDA LDT1 LDT2 MDV LHD1 LHD2 MHD HHD OBUS UBUS MCY SBUS MH Apartments Mid Rise 0.554639 0.059030 0.188043 0.120453 0.022437 0.005729 0.010970 0.007473 0.000973 0.000534 0.026133 0.000855 0.002730 Enclosed Parking with Elevator 0.554639 0.059030 0.188043 0.120453 0.022437 0.005729 0.010970 0.007473 0.000973 0.000534 0.026133 0.000855 0.002730
5.0 Energy Detail
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 26 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Electricity
Mitigated
0.0000 0.0000 0.0000 0.0000 0.0000 215.3276 215.3276 0.0348 4.2200e- 003
217.4568
Electricity
Unmitigated
0.0000 0.0000 0.0000 0.0000 0.0000 215.3276 215.3276 0.0348 4.2200e- 003
217.4568
NaturalGas
Mitigated
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 NaturalGas
Unmitigated
0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000
5.1 Mitigation Measures Energy
Historical Energy Use: N
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 27 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
5.2 Energy by Land Use - NaturalGas
NaturalGa
s Use
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Land Use kBTU/yr tons/yr MT/yr
Apartments Mid
Rise
0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Enclosed Parking
with Elevator
0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Total 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Unmitigated
NaturalGa
s Use
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Land Use kBTU/yr tons/yr MT/yr
Apartments Mid
Rise
0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Enclosed Parking
with Elevator
0 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Total 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 0.0000 Mitigated
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 28 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
6.0 Area Detail
5.3 Energy by Land Use - Electricity
Electricity
Use
Total CO2 CH4 N2O CO2e
Land Use kWh/yr MT/yr
Apartments Mid
Rise
1.41988e
+006
131.3723 0.0213 2.5800e-
003
132.6713
Enclosed Parking
with Elevator
907392 83.9553 0.0136 1.6500e-
003
84.7855
Total 215.3276 0.0348 4.2300e-
003
217.4568
Unmitigated
Electricity
Use
Total CO2 CH4 N2O CO2e
Land Use kWh/yr MT/yr
Apartments Mid
Rise
1.41988e
+006
131.3723 0.0213 2.5800e-
003
132.6713
Enclosed Parking
with Elevator
907392 83.9553 0.0136 1.6500e-
003
84.7855
Total 215.3276 0.0348 4.2300e-
003
217.4568
Mitigated
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 29 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5
6.1 Mitigation Measures Area
ROG NOx CO SO2 Fugitive
PM10
Exhaust
PM10
PM10
Total
Fugitive
PM2.5
Exhaust
PM2.5
PM2.5
Total
Bio- CO2 NBio- CO2 Total CO2 CH4 N2O CO2e
Category tons/yr MT/yr
Mitigated 1.1019 0.0193 1.6729 9.0000e-
005
9.2700e-
003
9.2700e-
003
9.2700e-
003
9.2700e-
003
0.0000 2.7364 2.7364 2.6300e-
003
0.0000 2.8023
Unmitigated 1.1019 0.0193 1.6729 9.0000e-
005
9.2700e-
003
9.2700e-
003
9.2700e-
003
9.2700e-
003
0.0000 2.7364 2.7364 2.6300e-
003
0.0000 2.8023
CalEEMod Version: CalEEMod.2020.4.0 Date: 10/12/2022 5:17 PMPage 30 of 36 1150-1170 Kifer Road - Bay Area AQMD Air District, Annual EMFAC Off-Model Adjustment Factors for Gasoline Light Duty Vehicle to Account for the SAFE Vehicle Rule Not Applied Attachment 5