Summary of Compliance Requirements
Table 1. Summary of Requirements if Using a Heat Pump
Ducts State Code Requirements Additional Local Code
Requirements
Existing
Duct sealing (10% leakage)
Airflow efficiency (300 CFM/ton)
Refrigerant charge verification
None
New
Duct sealing (5% leakage)
Airflow efficiency (350 CFM/ton)
Fan efficacy (0.58 W/CFM)
Refrigerant charge verification
Attic insulation (R-49)
Air sealing
R-8 Duct insulation
None
T
able 2. Summary of Requirements if Using a Furnace
Ducts State Code Requirements Additional Local Code
Requirements
Existing Duct sealing (10% leakage)
Airflow efficiency (300 CFM/ton)
Fan efficacy (0.45
watts/CFM)
Attic insulation (R-49)
Air sealing
New
Duct sealing (5% leakage)
Airflow efficiency (350 CFM/ton)
Fan efficacy (0.45 W/CFM)
Attic Insulation (R-49)
Air sealing
R-8 Duct insulation
Fan efficacy (0.35
watts/CFM)