Cities Index.
Attachment 5 Updated Architectural Plans dated August 21 2026

Thousand Oaks City Council
October 13, 2026

Document
Attachment 5 Updated Architectural Plans dated August 21 2026
Meeting
October 13, 2026
Body
Thousand Oaks City Council
Original file
325.6 MB
Text extracted from the city's file for reading and search. Open the original on toaks.primegov.com. That file is the official record.

PROJECT NA ME
DRAWN
JOB No.

SHEET TITLE
SHEET No.

ARCHITECTURE, INC.
reserves their common law
copyright in these documents.
they are not to be
reproduced, copied,
changed, nor assigned to a
third party without the written
consent of
this drawing(s) not for
construction without
architect's stamp and
original signature

DELTA/DATE ISSUED FOR
SHEET DATE 9/11/26
NY
G.1
Cover
#Pln
7/1/21 Initial Submittal

DICECCO
ARCHITECTURE, INC.

DICECCO People's Self Help Housing 384 Erbes Road Thousand Oaks Hillcrest Ow ner s hi p Hous i ng OWNER/CLIENT:

People's Self-Help Housing
1060 Kendall Rd.

San Luis Obispo, CA 93401
Attn: Jimmy Summer (805)548-2348
OWNER/CLIENT CONSULTANTS:

ARCHITECT:

DiCecco Architecture Incorporated
887 Patriot Drive, Suite C
Moorpark, CA 93021
Attn: Mark DiCecco Ph: (805) 552-0088 [email protected] STRUCTURAL ENGINEER:

R G S E, Inc.
2720 Cochran Street, Suite 8B
Simi Valley, CA 93065
Attn: Jeff Lubberts Ph: (805) 522-3379
MECHANICAL / ELECTRICAL /PLUMBING ENGINEER:

Consulting West Engineers
31340 Via Colinas, Suite 102
Westlake Village, CA 91362
Attn: Rich Adams, PE Ph: (818) 889-3383
CIVIL ENGINEER:

Encompass Consulting Group (ECG)
333 Lantana Street, Suite 287
Camarillo, CA 93012
Attn: Tristan Santos, PE Ph: (805) 322-4443
LANDSCAPE ARCHITECT:

MJS Landscape Architecture
507 30th Street
Newport Beach, CA 92663
Attn: Mark Schattinger, ASLA Ph: (949) 675-9964
CASP Consultant:

Thomas Jacob Flitsch Architects PC
860 Hampshire Road, Suite D,
Westlake Village, CA 91361
Attn: Tom Flitschr, AIA Ph: (805) 371-8600

REVISION LOG

PROJECT TEAM

H I L L C R E S T O W N E R S H I P H O U S I N G
3 8 4 E r b e s R o a d
T h o u s a n d O a k s , C A 9 1 3 6 2

PROJECT NAME
DRAWN
JOB No.

SHEET TITLE
SHEET No.

ARCHITECTURE, INC.
reserves their common law
copyright in these documents.
they are not to be
reproduced, copied,
changed, nor assigned to a
third party without the written
consent of
this drawing(s) not for
construction without
architect's stamp and
original signature

DELTA/DATE ISSUED FOR
SHEET DATE 8/27/26
22206
08/05/24 1ST City Submittal

DICECCO
ARCHITECTURE, INC.

DICECCO

ARCHITECT
CONSULTANTHillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal
08/21/26 3RD City Submittal
08/21/26 Deck Removal
1 2
3 DELTA DATE ARCH. STRUCT MECH PLUMB ELEC CIVIL LANDSCAPE

SHEETS REVISED
OWNER
ARCH
CITY

REMARKS

COVER SHEET
A0.0

SHEET INDEX PROJECT SUMMARY AND ANALYSIS

1. PROJECT SUMMARY:

PROJECT DESCRIPTION
3 SITE WALL PLANS - FOR REFERENCE ONLY

LANDSCAPE PLANS - FOR REFERENCE ONLY
1 COVER SHEET
2 CMU WALL NOTES
3 CMU WALL NOTES
4 SHORING WALL NOTES
5 SHORING WALL NOTES
6 WALL 1 PLAN & PROFILE
7 WALL 2 PLAN & PROFILE
8 WALL 3 PLAN & PROFILE
9 WALL 3,2 PLAN & PROFILE
10 WALL 4 PLAN & PROFILE
11 WALL 5 PLAN & PROFILE
12 WALL 6,7 PLAN & PROFILE
13 CMU WALL DETAILS
14 CMU WALL DETAILS
15 SHORING DETAILS
16 CMU WALL SITE PLAN
17 SHORING WALL PLAN
18 SHORING WALL PROFILE WEST WALL
19 SHORING WALL PROFILE NORTH WALL
20 SHORING WALL PROFILE NORTH EAST WALL
21 SHORING WALL SECTIONS
22 SHORING WALL SECTIONS
23 SHORING WALL SECTIONS
LT.0 COVER SHEET
COA.1 CONDITIONS OF APPROVAL
LWF.1 WALL & FENCE PLAN
LC.A CONSTRUCTION NOTES & PAVING SCHEDULE
LC.B MATERIAL BOARD/LANDSCAPE CUT SHEETS
LC.1 thru LC.5 CONSTRUCTION PLAN
LD.1 thru LD.5 DIMENSION PLAN
LCD.1 CONSTRUCTION DETAILS
LCS.1 CONSTRUCTION SPECIFICATIONS
LI.1 thru LI.5 IRRIGATION PLAN
LI.6 IRRIGATION LEGEND
LI.7 IRRIGATION WATER USE DATA
LI.8 thru LI.9 IRRIGATION DETAILS
LI.10 IRRIGATION SPECIFICATIONS
LP.A SITE PLAN FUEL MODIFICATION
LPT.1 thru LPT.5 TREE & VINE PLAN
LPS.1 thru LPS.5 SHRUB PLAN
LPD.0 VCFD NOTES & DIAGRAMS
LPD.1 PLANTING DETAILS
LPD.2 PROTECTED TREE REPORT
LPD.3 PLANTING SPECIFICATIONS
LL.1 thru LL.5 LANDSCAPE LIGHTING PLAN (for COORDINATION ONLY) ATTACHMENT #5
PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 3/4/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 CONDITIONS OF APPROVAL CONDITIONS OF APPROVAL A0.1
1 23
4 5
6 789 1011 12 131415
PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 3/4/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 CONDITIONS OF APPROVAL CONDITIONS OF APPROVAL A0.1.1 1 23
4 5
6 789 1011 12 131415
PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 3/4/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 CONDITIONS OF APPROVAL CONDITIONS OF APPROVAL A0.1.2 1 23
4 5
6 789 1011 12 131415
PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 3/4/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 CONDITIONS OF APPROVAL CONDITIONS OF APPROVAL A0.1.3 1 23
4 5
6 789 1011 12 131415
CHAPTER 4 RESIDENTIAL MANDATORY MEASURES DIVISION 4.1 PLANNING AND DESIGN DIVISION 4.3 WATER EFFICIENCY AND CONSERVATION 4.406 ENHANCED DURABILITY AND REDUCED MAINTENANCE 4.406.1 RODENT PROOFING. Annular spaces around pipes, electric cables, conduits or other openings in sole/bottom plates at exterior walls shall be protected against the passage of rodents by closing such openings with cement mortar, concrete masonry or a similar method acceptable to the enforcing agency. 4.408 CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING 4.408.1 CONSTRUCTION WASTE MANAGEMENT. Recycle and/or salvage for reuse a minimum of 65 percent of the non-hazardous construction and demolition waste in accordance with either Section 4.408.2, 4.408.3 or 4.408.4, or meet a more stringent local construction and demolition waste management ordinance. Exceptions: 1. Excavated soil and land-clearing debris. 2. Alternate waste reduction methods developed by working with local agencies if diversion or recycle facilities capable of compliance with this item do not exist or are not located reasonably close to the jobsite. 3. The enforcing agency may make exceptions to the requirements of this section when isolated jobsites are located in areas beyond the haul boundaries of the diversion facility. 4.408.2 CONSTRUCTION WASTE MANAGEMENT PLAN. Submit a construction waste management plan in conformance with Items 1 through 5. The construction waste management plan shall be updated as necessary and shall be available during construction for examination by the enforcing agency. 1. Identify the construction and demolition waste materials to be diverted from disposal by recycling, reuse on the project or salvage for future use or sale. 2. Specify if construction and demolition waste materials will be sorted on-site (source separated) or bulk mixed (single stream). 3. Identify diversion facilities where the construction and demolition waste material collected will be taken. 4. Identify construction methods employed to reduce the amount of construction and demolition waste generated. 5. Specify that the amount of construction and demolition waste materials diverted shall be calculated by weight or volume, but not by both. 4.408.3 WASTE MANAGEMENT COMPANY. Utilize a waste management company, approved by the enforcing agency, which can provide verifiable documentation that the percentage of construction and demolition waste material diverted from the landfill complies with Section 4.408.1. Note: The owner or contractor may make the determination if the construction and demolition waste materials will be diverted by a waste management company. 4.408.4 WASTE STREAM REDUCTION ALTERNATIVE [LR]. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 3.4 lbs./sq.ft. of the building area shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.4.1 WASTE STREAM REDUCTION ALTERNATIVE. Projects that generate a total combined weight of construction and demolition waste disposed of in landfills, which do not exceed 2 pounds per square foot of the building area, shall meet the minimum 65% construction waste reduction requirement in Section 4.408.1 4.408.5 DOCUMENTATION. Documentation shall be provided to the enforcing agency which demonstrates compliance with Section 4.408.2, items 1 through 5, Section 4.408.3 or Section 4.408.4.. Notes:1. Sample forms found in "A Guide to the California Green Building Standards Code (Residential)" located at www.hcd.ca.gov/CALGreen.html may be used to assist in documenting compliance with this section.

2. Mixed construction and demolition debris (C & D) processors can be located at the California Department of Resources Recycling and Recovery (CalRecycle). 4.410 BUILDING MAINTENANCE AND OPERATION 4.410.1 OPERATION AND MAINTENANCE MANUAL. At the time of final inspection, a manual, compact disc, web-based reference or other media acceptable to the enforcing agency which includes all of the following shall be placed in the building:

1. Directions to the owner or occupant that the manual shall remain with the building throughout the life cycle of the structure.

2. Operation and maintenance instructions for the following:
a. Equipment and appliances, including water-saving devices and systems, HVAC systems, photovoltaic systems, electric vehicle chargers, water-heating systems and other major appliances and equipment. b. Roof and yard drainage, including gutters and downspouts. c. Space conditioning systems, including condensers and air filters.d. Landscape irrigation systems.e. Water reuse systems.

3. Information from local utility, water and waste recovery providers on methods to further reduce resource consumption, including recycle programs and locations.

4. Public transportation and/or carpool options available in the area.

5. Educational material on the positive impacts of an interior relative humidity between 30-60 percent and what methods an occupant may use to maintain the relative humidity level in that range.

6. Information about water-conserving landscape and irrigation design and controllers which conserve water. 7. Instructions for maintaining gutters and downspouts and the importance of diverting water at least 5 feet away from the foundation.

8. Information on required routine maintenance measures, including, but not limited to, caulking, painting, grading around the building, etc.

9. Information about state solar energy and incentive programs available.

10. A copy of all special inspections verifications required by the enforcing agency or this code.11. Information from the Department of Forestry and Fire Protection on maintenance of defensible space around residential structures.

12. Information and/or drawings identifying the location of grab bar reinforcements. 4.410.2 RECYCLING BY OCCUPANTS. Where 5 or more multifamily dwelling units are constructed on a building site, provide readily accessible area(s) that serves all buildings on the site and are identified for the depositing, storage and collection of non-hazardous materials for recycling, including (at a minimum) paper, corrugated cardboard, glass, plastics, organic waster, and metals, or meet a lawfully enacted local recycling ordinance, if more restrictive.

Exception: Rural jurisdictions that meet and apply for the exemption in Public Resources Code Section 42649.82 (a)(2)(A) et seq. are note required to comply with the organic waste portion of this section. DIVISION 4.4 MATERIAL CONSERVATION AND RESOURCE EFFICIENCY DIVISION 4.5 ENVIRONMENTAL QUALITY 4.303 INDOOR WATER USE 4.303.1 WATER CONSERVING PLUMBING FIXTURES AND FITTINGS. Plumbing fixtures (water closets and urinals) and fittings (faucets and showerheads) shall comply with the sections 4.303.1.1, 4.303.1.2, 4.303.1.3, and 4.303.4.4. Note: All noncompliant plumbing fixtures in any residential real property shall be replaced with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy, or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 4.303.1.1 Water Closets. The effective flush volume of all water closets shall not exceed 1.28 gallons per flush. Tank-type water closets shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Tank-type Toilets. Note: The effective flush volume of dual flush toilets is defined as the composite, average flush volume of two reduced flushes and one full flush. 4.303.1.2 Urinals. The effective flush volume of wall mounted urinals shall not exceed 0.125 gallons per flush. The effective flush volume of all other urinals shall not exceed 0.5 gallons per flush. 4.303.1.3 Showerheads. 4.303.1.3.1 Single Showerhead. Showerheads shall have a maximum flow rate of not more than 1.8 gallons per minute at 80 psi. Showerheads shall be certified to the performance criteria of the U.S. EPA WaterSense Specification for Showerheads. 4.303.1.3.2 Multiple showerheads serving one shower. When a shower is served by more than one showerhead, the combined flow rate of all the showerheads and/or other shower outlets controlled by a single valve shall not exceed 1.8 gallons per minute at 80 psi, or the shower shall be designed to only allow one shower outlet to be in operation at a time. Note: A hand-held shower shall be considered a showerhead. 4.303.1.4 Faucets. 4.303.1.4.1 Residential Lavatory Faucets. The maximum flow rate of residential lavatory faucets shall not exceed 1.2 gallons per minute at 60 psi. The minimum flow rate of residential lavatory faucets shall not be less than 0.8 gallons per minute at 20 psi. 4.303.1.4.2 Lavatory Faucets in Common and Public Use Areas. The maximum flow rate of lavatory faucets installed in common and public use areas (outside of dwellings or sleeping units) in residential buildings shall not exceed 0.5 gallons per minute at 60 psi. 4.303.1.4.3 Metering Faucets. Metering faucets when installed in residential buildings shall not deliver more than 0.2 gallons per cycle. 4.303.1.4.4 Kitchen Faucets. The maximum flow rate of kitchen faucets shall not exceed 1.8 gallons per minute at 60 psi. Kitchen faucets may temporarily increase the flow above the maximum rate, but not to exceed 2.2 gallons per minute at 60 psi, and must default to a maximum flow rate of 1.8 gallons per minute at 60 psi. Note: Where complying faucets are unavailable, aerators or other means may be used to achieve reduction. 4.303.1.4.5 Pre-rinse spray valves. When installed, shall meet the requirements in the California Code of Regulations, Title 20 (Appliance Efficiency Regulations), Sections 1605.1 (h)(4) Table H-2, Section 1605.3 (h)(4)(A), and Section 1607 (d)(7) and shall be equipped with an integral automatic shutoff. FOR REFERENCE ONLY: The following table and code section have been reprinted from the California Code of Regulations, Title 20 (Appliance Efficiency Regulations),Section 1605.1 (h)(4) and Section 1605.3 (h)(4)(A). Title 20 Section 1605.3 (h)(4)(A): Commercial prerinse spray values manufactured on or after January 1, 2006, shall have a minimum spray force of not less than 4.0 ounces-force (ozf)[113 grams-force(gf)] 4.303.2 Submeters for multifamily buildings and dwelling units in mixed-used residential/commercial buildings. Submeters shall be installed to measure water usage of individual rental dwelling units in accordance with the California Plumbing Code. 4.303.3 Standards for plumbing fixtures and fittings. Plumbing fixtures and fittings shall be installed in accordance with the California Plumbing Code, and shall meet the applicable standards referenced in Table 1701.1 of the California Plumbing Code. TABLE - MAXIMUM FIXTURE WATER USE FIXTURE TYPE FLOW RATE SHOWER HEADS (RESIDENTIAL) 1.8 GMP @ 80 PSI LAVATORY FAUCETS (RESIDENTIAL) MAX. 1.2 GPM @ 60 PSI MIN. 0.8 GPM @ 20 PSI LAVATORY FAUCETS IN COMMON & PUBLIC USE AREAS 0.5 GPM @ 60 PSI KITCHEN FAUCETS 1.8 GPM @ 60 PSI METERING FAUCETS 0.2 GAL/CYCLE WATER CLOSET 1.28 GAL/FLUSH URINALS 0.125 GAL/FLUSH 4.304 OUTDOOR WATER USE 4.304.1 OUTDOOR POTABLE WATER USE IN LANDSCAPE AREAS. Residential developments shall comply with a local water efficient landscape ordinance or the current California Department of Water Resources' Model Water Efficient Landscape Ordinance (MWELO), whichever is more stringent. NOTES: 1. The Model Water Efficient Landscape Ordinance (MWELO) is located in the California Code Regulations, Title 23, Chapter 2.7, Division 2. MWELO and supporting documents, including water budget calculator, are available at: https://www.water.ca.gov/ ABBREVIATION DEFINITIONS: HCD Department of Housing and Community Development BSC California Building Standards Commission DSA-SS Division of the State Architect, Structural Safety OSHPD Office of Statewide Health Planning and Development LR Low Rise HR High Rise AA Additions and Alterations N New NOTE: THIS TABLE COMPILES THE DATA IN SECTION 4.303.1, AND IS INCLUDED AS A CONVENIENCE FOR THE USER. SECTION 4.102 DEFINITIONS 4.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) FRENCH DRAIN. A trench, hole or other depressed area loosely filled with rock, gravel, fragments of brick or similar pervious material used to collect or channel drainage or runoff water. WATTLES. Wattles are used to reduce sediment in runoff. Wattles are often constructed of natural plant materials such as hay, straw or similar material shaped in the form of tubes and placed on a downflow slope. Wattles are also used for perimeter and inlet controls. 4.106 SITE DEVELOPMENT 4.106.1 GENERAL. Preservation and use of available natural resources shall be accomplished through evaluation and careful planning to minimize negative effects on the site and adjacent areas. Preservation of slopes, management of storm water drainage and erosion controls shall comply with this section. 4.106.2 STORM WATER DRAINAGE AND RETENTION DURING CONSTRUCTION. Projects which disturb less than one acre of soil and are not part of a larger common plan of development which in total disturbs one acre or more, shall manage storm water drainage during construction. In order to manage storm water drainage during construction, one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site. 1. Retention basins of sufficient size shall be utilized to retain storm water on the site. 2. Where storm water is conveyed to a public drainage system, collection point, gutter or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the enforcing agency. 3. Compliance with a lawfully enacted storm water management ordinance. Note: Refer to the State Water Resources Control Board for projects which disturb one acre or more of soil, or are part of a larger common plan of development which in total disturbs one acre or more of soil. (Website: https://www.waterboards.ca.gov/water_issues/programs/stormwater/construction.html) 4.106.3 GRADING AND PAVING. Construction plans shall indicate how the site grading or drainage system will manage all surface water flows to keep water from entering buildings. Examples of methods to manage surface water include, but are not limited to, the following: 1. Swales 2. Water collection and disposal systems 3. French drains 4. Water retention gardens

5. Other water measures which keep surface water away from buildings and aid in groundwater recharge.

Exception: Additions and alterations not altering the drainage path.

4.106.4 Electric vehicle (EV) charging for new construction. New construction shall comply with Section 4.106.4.1 or 4.106.4.2. Electric vehicle supply equipment (EVSE) shall comply with the California Electrical Code. Exceptions:

1. On a case-by-case basis, where the local enforcing agency has determined EV charging and infrastructure are not feasible based upon one or more of the following conditions:

1.1 Where there is no local utility power supply or the local utility is unable to supply adequate power. 1.2 Where there is evidence suitable to the local enforcing agency substantiating that additional local utility infrastructure design requirements, directly related to the implementation of Section

4.106.4, may adversely impact the construction cost of the project.

2. Accessory Dwelling Units (ADU) and Junior Accessory Dwelling Units (JADU) without additional parking facilities.

4.106.4.1 New one- and two-family dwellings and townhouses with attached private garages. For each dwelling unit, install a listed raceway to accommodate a dedicated 208/240-volt branch circuit. The raceway shall not be less than trade size 1 (nominal 1-inch inside diameter). The raceway shall originate at the main service or subpanel and shall terminate into a listed cabinet, box or other enclosure in close proximity to the proposed location of an EV charger. Raceways are required to be continuous at enclosed, inaccessible or concealed areas and spaces. The service panel and/or subpanel shall provide capacity to install a 40-ampere 208/240-volt minimum dedicated branch circuit and space(s) reserved to permit installation of a branch circuit overcurrent protective device.

Exemption: A raceway is not required if a minimum 40-ampere 208/240-volt dedicated EV branch circuit is installed in close proximity to the proposed location of an EV charger at the time of original construction in accordance with the California Electrical Code. 4.106.4.1.1 Identification. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging as "EV CAPABLE". The raceway terminationlocation shall be permanently and visibly marked as "EV CAPABLE". CHAPTER 3 GREEN BUILDING SECTION 301 GENERAL 301.1 SCOPE. Buildings shall be designed to include the green building measures specified as mandatory in the application checklists contained in this code. Voluntary green building measures are also included in the application checklists and may be included in the design and construction of structures covered by this code, but are not required unless adopted by a city, county, or city and county as specified in Section 101.7. 301.1.1 Additions and alterations. [HCD] The mandatory provisions of Chapter 4 shall be applied to additions or alterations of existing residential buildings where the addition or alteration increases the building's conditioned area, volume, or size. The requirements shall apply only to and/or within the specific area of the addition or alteration. The mandatory provision of Section 4.106.4.2 may apply to additions or alterations of existing parking facilities or the addition of new parking facilities serving existing multifamily buildings. See Section 4.106.4.3 for application. Note: Repairs including, but not limited to, resurfacing, restriping and repairing or maintaining existing lighting fixtures are not considered alterations for the purpose of this section. Note: On and after January 1, 2014, residential buildings undergoing permitted alterations, additions, or improvements shall replace noncompliant plumbing fixtures with water-conserving plumbing fixtures. Plumbing fixture replacement is required prior to issuance of a certificate of final completion, certificate of occupancy or final permit approval by the local building department. See Civil Code Section 1101.1, et seq., for the definition of a noncompliant plumbing fixture, types of residential buildings affected and other important enactment dates. 301.2 LOW-RISE AND HIGH-RISE RESIDENTIAL BUILDINGS. [HCD] The provisions of individual sections of CALGreen may apply to either low-rise residential buildings high-rise residential buildings, or both. Individual sections will be designated by banners to indicate where the section applies specifically to low-rise only (LR) or high-rise only (HR). When the section applies to both low-rise and high-rise buildings, no banner will be used. SECTION 302 MIXED OCCUPANCY BUILDINGS 302.1 MIXED OCCUPANCY BUILDINGS. In mixed occupancy buildings, each portion of a building shall comply with the specific green building measures applicable to each specific occupancy. Exceptions: 1. [HCD] Accessory structures and accessory occupancies serving residential buildings shall comply with Chapter 4 and Appendix A4, as applicable. 2. [HCD] For purposes of CALGreen, live/work units, complying with Section 419 of the California Building Code, shall not be considered mixed occupancies. Live/Work units shall comply with Chapter 4 and Appendix A4, as applicable. 4.106.4.2 New multifamily dwellings, hotels and motels and new residential parking facilities. When parking is provided, parking spaces for new multifamily dwellings, hotels and motels shall meet the requirements of Section 4.106.4.2.2. Calculations for spaces shall be rounded up to the nearest whole number. A parking space served by electric vehicle supply equipment or designed as an EV charging space shall count as at least one standard automobile parking space only for the purpose of complying with any applicable minimum parking space requirements established by a local jurisdiction. See Vehicle Code Section 22511.2 for further details. 4.106.4.2.1 Reserved. 4.106.4.2.2 Multifamily dwellings, hotels and motels 1. EV ready parking spaces with receptacles. a. Hotels and motels. Forty (40) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. b. Multifamily parking facilities. Forty (40) percent of the total number of parking spaces shall be equipped with low power Level 2 EV charging receptacles. EV charging receptacles required by this section shall be located in at least one assigned parking space per dwelling unit where assigned parking is provided but need not exceed forty (40) percent of the total number of assigned parking spaces provided on the site. Exception: Areas of parking facilities served by parking lifts, including but not limited to automated mechanical-access open parking garages as defined in the California Building Code; or parking facilities otherwise incapable of supporting electric vehicle charging. c. Receptacle power source. EV charging receptacles in multifamily parking facilities shall be provided with a dedicated branch circuit connected to the dwelling unit’s electrical panel, unless determined as infeasible by the project builder or designer and subject to concurrence of the local enforcing agency. Exception: Areas of parking facilities served by parking lifts, including but not limited to automated mechanical-access open parking garages as defined in the California Building Code; or parking facilities otherwise incapable of supporting electric vehicle charging. d. Receptacle configurations. 208/240V EV charging receptacles shall comply with one of the following configurations: 1. For 20-ampere receptacles, NEMA 6-20R 2. For 30-ampere receptacles, NEMA 14-30R 3. For 50-ampere receptacles, NEMA 14-50R 2. EV ready parking spaces with EV chargers. a. Hotels and motels. Ten (10) percent of the total number of parking spaces shall be equipped with Level 2 EV chargers. At least fifty (50) percent of the required EV chargers shall be equipped with J1772 connectors. b. Multifamily parking facilities. Ten (10) percent of the total number of parking spaces shall be equipped with Level 2 EV chargers. At least fifty (50) percent of the required EV chargers shall be equipped with J1772 connectors. Where common use parking or unassigned parking is provided, EV chargers shall be located in common use or unassigned parking areas and shall be available for use by all residents or guests. Where low power Level 2 EV charging receptacles or Level 2 EV chargers are installed beyond the minimum required, an automatic load management system (ALMS) may be used to reduce the maximum required electrical capacity to each space served by the ALMS. The electrical system and any on-site distribution transformers shall have sufficient capacity to deliver at least 3.3 kW simultaneously to each EV charging station (EVCS) served by the ALMS. The branch circuit shall have a minimum capacity of 40 amperes, and installed EV chargers shall have a capacity of not less than 30 amperes. 4.106.4.2.2.1 Electric vehicle charging stations (EVCS). Electric vehicle charging stations required by Section 4.106.4.2.2, Item 2, with EV chargers installed shall comply with Section 4.106.4.2.2.1.1. Exception: Electric vehicle charging stations serving public accommodations, public housing, motels and hotels shall not be required to comply with this section. See California Building Code, Chapter 11B, for applicable requirements. 4.106.4.2.2.1.1 Electric vehicle charging stations (EVCS) spaces with EV chargers installed; dimensions and location. EVCS spaces shall be designed to comply with the following: 1. The minimum length of each EVCS space shall be 18 feet (5486 mm). 2. The minimum width of each EVCS space shall be 9 feet (2743 mm). 3. One in every 25 EVCS spaces, but not less than one, shall also have an 8-foot (2438 mm) wide minimum aisle. A 5-foot (1524 mm) wide minimum aisle shall be permitted provided the minimum width of the EVCS space is 12 feet (3658 mm). Surface slope for this EVCS space and the aisle shall not exceed 1 unit vertical in 48 units horizontal (2.083 percent slope) in any direction. These EVCS spaces shall also comply with at least one of the following: a. The EVCS space shall be located adjacent to an accessible parking space meeting the requirements of the California Building Code, Chapter 11A, to allow use of the EV charger from the accessible parking space. b. The EVCS space shall be located on an accessible route, as defined in the California Building Code, Chapter 2, to the building. Exception: Electric vehicle charging stations designed and constructed in compliance with the California Building Code, Chapter 11B, are not required to comply with Section 4.106.4.2.2.1.1. 4.106.4.2.2.1.2 Accessible electric vehicle charging station spaces. In addition to the requirements in Section 4.106.4.2.2.1.1, all EV chargers, where installed, shall comply with the accessibility provisions for EV chargers in the California Building Code, Chapter 11B. EV ready spaces and EVCS in multifamily developments shall comply with California Building Code, Chapter 11A, Section 1109A. 4.106.4.2.3 Reserved. 4.106.4.2.4 Reserved. 4.106.4.2.5 Electric vehicle ready space signage. Electric vehicle ready spaces shall be identified by signage or pavement markings, in compliance with Caltrans Traffic Operations Policy Directive 13-01 (Zero Emission Vehicle Signs and Pavement Markings) or its successor(s). 4.106.4.3 Electric vehicle charging for additions and alterations of parking facilities serving existing multi-family buildings. Where new parking facilities are added, or electrical systems or lighting of existing parking facilities are added or altered and the work requires a building permit, ten (10) percent of the total number of parking spaces added or altered shall be EV capable spaces to support future Level 2 electric vehicle supply equipment. The service panel or subpanel circuit directory shall identify the overcurrent protective device space(s) reserved for future EV charging purposes as “EV CAPABLE.” Notes: 1.Construction documents are intended to demonstrate the project’s capability and capacity for facilitating future EV charging. 2.There is no requirement for EV spaces to be constructed or available until EV chargers are installed for use. SECTION 4.501 GENERAL 4.501.1 Scope The provisions of this chapter shall outline means of reducing the quality of air contaminants that are odorous, irritating and/or harmful to the comfort and well being of a building's installers, occupants and neighbors. SECTION 4.502 DEFINITIONS 5.102.1 DEFINITIONS The following terms are defined in Chapter 2 (and are included here for reference) AGRIFIBER PRODUCTS. Agrifiber products include wheatboard, strawboard, panel substrates and door cores, not including furniture, fixtures and equipment (FF&E) not considered base building elements. COMPOSITE WOOD PRODUCTS. Composite wood products include hardwood plywood, particleboard and medium density fiberboard. "Composite wood products" does not include hardboard, structural plywood, structural panels, structural composite lumber, oriented strand board, glued laminated timber, prefabricated wood I-joists or finger-jointed lumber, all as specified in California Code of regulations (CCR), title 17, Section 93120.1. DIRECT-VENT APPLIANCE. A fuel-burning appliance with a sealed combustion system that draws all air for combustion from the outside atmosphere and discharges all flue gases to the outside atmosphere. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE.

Y N/A RESPON.

Y N/A
Y N/A
Y N/A PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 1 (July 2024 Supplement) Y = YES N/A = NOT APPLICABLE RESPON. PARTY = RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) 4.201 GENERAL 4.201.1 SCOPE. For the purposes of mandatory energy efficiency standards in this code, the California Energy Commission will continue to adopt mandatory standards. DIVISION 4.2 ENERGY EFFICIENCY TABLE H-2 STANDARDS FOR COMMERCIAL PRE-RINSE SPRAY VALUES MANUFACTURED ON OR AFTER JANUARY 28, 2019 PRODUCT CLASS [spray force in ounce force (ozf)] MAXIMUM FLOW RATE (gpm) Product Class 1 (
≤ 1.00 Product Class 2 (> 5.0 ozf and
≤ 1.20 Product Class 3 (> 8.0 ozf) 1.28 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 3/4/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 CAL-GREEN RESIDENTIAL MEASURES CAL GREEN COMPLIANCE A0.3 MAXIMUM INCREMENTAL REACTIVITY (MIR). The maximum change in weight of ozone formed by adding a compound to the "Base Reactive Organic Gas (ROG) Mixture" per weight of compound added, expressed to hundredths of a gram (g O³/g ROC).

Note: MIR values for individual compounds and hydrocarbon solvents are specified in CCR, Title 17, Sections 94700 and 94701. MOISTURE CONTENT. The weight of the water in wood expressed in percentage of the weight of the oven-dry wood.PRODUCT-WEIGHTED MIR (PWMIR). The sum of all weighted-MIR for all ingredients in a product subject to this article. The PWMIR is the total product reactivity expressed to hundredths of a gram of ozone formed per gram of product (excluding container and packaging).

Note: PWMIR is calculated according to equations found in CCR, Title 17, Section 94521 (a).REACTIVE ORGANIC COMPOUND (ROC). Any compound that has the potential, once emitted, to contribute to ozone formation in the troposphere. VOC. A volatile organic compound (VOC) broadly defined as a chemical compound based on carbon chains or rings with vapor pressures greater than 0.1 millimeters of mercury at room temperature. These compounds typically contain hydrogen and may contain oxygen, nitrogen and other elements. See CCR Title 17, Section 94508(a). 4.503 FIREPLACES 4.503.1 GENERAL. Any installed gas fireplace shall be a direct-vent sealed-combustion type. Any installed woodstove or pellet stove shall comply with U.S. EPA New Source Performance Standards (NSPS) emission limits as applicable, and shall have a permanent label indicating they are certified to meet the emission limits. Woodstoves, pellet stoves and fireplaces shall also comply with applicable local ordinances. 4.504 POLLUTANT CONTROL 4.504.1 COVERING OF DUCT OPENINGS & PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. At the time of rough installation, during storage on the construction site and until final startup of the heating, cooling and ventilating equipment, all duct and other related air distribution component openings shall be covered with tape, plastic, sheet metal or other methods acceptable to the enforcing agency to reduce the amount of water, dust or debris which may enter the system. 4.504.2 FINISH MATERIAL POLLUTANT CONTROL. Finish materials shall comply with this section.

4.504.2.1 Adhesives, Sealants and Caulks. Adhesives, sealant and caulks used on the project shall meet the requirements of the following standards unless more stringent local or regional air pollution or air quality management district rules apply:

1. Adhesives, adhesive bonding primers, adhesive primers, sealants, sealant primers and caulks shall comply with local or regional air pollution control or air quality management district rules where applicable or SCAQMD Rule 1168 VOC limits, as shown in Table 4.504.1 or 4.504.2, as applicable. Such products also shall comply with the Rule 1168 prohibition on the use of certain toxic compounds (chloroform, ethylene dichloride, methylene chloride, perchloroethylene and tricloroethylene), except for aerosol products, as specified in Subsection 2 below.

2. Aerosol adhesives, and smaller unit sizes of adhesives, and sealant or caulking compounds (in units of product, less packaging, which do not weigh more than 1 pound and do not consist of more than 16 fluid ounces) shall comply with statewide VOC standards and other requirements, including prohibitions on use of certain toxic compounds, of California Code of Regulations, Title 17, commencing with section 94507.

4.504.2.2 Paints and Coatings. Architectural paints and coatings shall comply with VOC limits in Table 1 of the ARB Architectural Suggested Control Measure, as shown in Table 4.504.3, unless more stringent local limits apply. The VOC content limit for coatings that do not meet the definitions for the specialty coatings categories listed in Table 4.504.3 shall be determined by classifying the coating as a Flat, Nonflat or Nonflat-High Gloss coating, based on its gloss, as defined in subsections 4.21, 4.36, and 4.37 of the 2007 California Air Resources Board, Suggested Control Measure, and the corresponding Flat, Nonflat or Nonflat-High Gloss VOC limit in Table 4.504.3 shall apply.

4.504.2.3 Aerosol Paints and Coatings. Aerosol paints and coatings shall meet the Product-weighted MIR Limits for ROC in Section 94522(a)(2) and other requirements, including prohibitions on use of certain toxic compounds and ozone depleting substances, in Sections 94522(e)(1) and (f)(1) of California Code of Regulations, Title 17, commencing with Section 94520; and in areas under the jurisdiction of the Bay Area Air Quality Management District additionally comply with the percent VOC by weight of product limits of Regulation8, Rule 49. 4.504.2.4 Verification. Verification of compliance with this section shall be provided at the request of the enforcing agency. Documentation may include, but is not limited to, the following:

1. Manufacturer's product specification.

2. Field verification of on-site product containers. CHAPTER 7 INSTALLER & SPECIAL INSPECTOR QUALIFICATIONS 702 QUALIFICATIONS 702.1 INSTALLER TRAINING. HVAC system installers shall be trained and certified in the proper installation of HVAC systems including ducts and equipment by a nationally or regionally recognized training or certification program. Uncertified persons may perform HVAC installations when under the direct supervision and responsibility of a person trained and certified to install HVAC systems or contractor licensed to install HVAC systems. Examples of acceptable HVAC training and certification programs include but are not limited to the following: 1. State certified apprenticeship programs. 2. Public utility training programs. 3. Training programs sponsored by trade, labor or statewide energy consulting or verification organizations. 4. Programs sponsored by manufacturing organizations. 5. Other programs acceptable to the enforcing agency. 702.2 SPECIAL INSPECTION [HCD]. When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition to other certifications or qualifications acceptable to the enforcing agency, the following certifications or education may be considered by the enforcing agency when evaluating the qualifications of a special inspector: 1. Certification by a national or regional green building program or standard publisher. 2. Certification by a statewide energy consulting or verification organization, such as HERS raters, building performance contractors, and home energy auditors. 3. Successful completion of a third party apprentice training program in the appropriate trade. 4. Other programs acceptable to the enforcing agency. Notes:1. Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 2. HERS raters are special inspectors certified by the California Energy Commission (CEC) to rate homes in California according to the Home Energy Rating System (HERS). [BSC] When required by the enforcing agency, the owner or the responsible entity acting as the owner's agent shall employ one or more special inspectors to provide inspection or other duties necessary to substantiate compliance with this code. Special inspectors shall demonstrate competence to the satisfaction of the enforcing agency for the particular type of inspection or task to be performed. In addition, the special inspector shall have a certification from a recognized state, national or international association, as determined by the local agency. The area of certification shall be closely related to the primary job function, as determined by the local agency. Note: Special inspectors shall be independent entities with no financial interest in the materials or the project they are inspecting for compliance with this code. 703 VERIFICATIONS 703.1 DOCUMENTATION. Documentation used to show compliance with this code shall include but is not limited to, construction documents, plans, specifications, builder or installer certification, inspection reports, or other methods acceptable to the enforcing agency which demonstrate substantial conformance. When specific documentation or special inspection is necessary to verify compliance, that method of compliance will be specified in the appropriate section or identified applicable checklist. 4.505 INTERIOR MOISTURE CONTROL 4.505.1 General. Buildings shall meet or exceed the provisions of the California Building Standards Code. 4.505.2 CONCRETE SLAB FOUNDATIONS. Concrete slab foundations required to have a vapor retarder by California Building Code, Chapter 19, or concrete slab-on-ground floors required to have a vapor retarder by theCalifornia Residential Code, Chapter 5, shall also comply with this section.

4.505.2.1 Capillary break. A capillary break shall be installed in compliance with at least one of the following:

1. A 4-inch (101.6 mm) thick base of 1/2 inch (12.7mm) or larger clean aggregate shall be provided with a vapor barrier in direct contact with concrete and a concrete mix design, which will address bleeding, shrinkage, and curling, shall be used. For additional information, see American Concrete Institute, ACI 302.2R-06. 2. Other equivalent methods approved by the enforcing agency.

3. A slab design specified by a licensed design professional. 4.505.3 MOISTURE CONTENT OF BUILDING MATERIALS. Building materials with visible signs of water damage shall not be installed. Wall and floor framing shall not be enclosed when the framing members exceed 19 percent moisture content. Moisture content shall be verified in compliance with the following:

1. Moisture content shall be determined with either a probe-type or contact-type moisture meter.Equivalent moisture verification methods may be approved by the enforcing agency and shall satisfy requirements found in Section 101.8 of this code. 2. Moisture readings shall be taken at a point 2 feet (610 mm) to 4 feet (1219 mm) from the grade stamped end of each piece verified.

3. At least three random moisture readings shall be performed on wall and floor framing with documentation acceptable to the enforcing agency provided at the time of approval to enclose the wall and floor framing.

Insulation products which are visibly wet or have a high moisture content shall be replaced or allowed to dry prior to enclosure in wall or floor cavities. Wet-applied insulation products shall follow the manufacturers' drying recommendations prior to enclosure. 4.506 INDOOR AIR QUALITY AND EXHAUST 4.506.1 Bathroom exhaust fans. Each bathroom shall be mechanically ventilated and shall comply with the following:

1. Fans shall be ENERGY STAR compliant and be ducted to terminate outside the building.

2. Unless functioning as a component of a whole house ventilation system, fans must be controlled by a humidity control.
a. Humidity controls shall be capable of adjustment between a relative humidity range less than or equal to 50% to a maximum of 80%. A humidity control may utilize manual or automatic means of adjustment. b. A humidity control may be a separate component to the exhaust fan and is not required to be integral (i.e., built-in) Notes:1. For the purposes of this section, a bathroom is a room which contains a bathtub, shower or tub/shower combination. 2. Lighting integral to bathroom exhaust fans shall comply with the California Energy Code. 4.507 ENVIRONMENTAL COMFORT 4.507.2 HEATING AND AIR-CONDITIONING SYSTEM DESIGN. Heating and air conditioning systems shall be sized, designed and have their equipment selected using the following methods:

1. The heat loss and heat gain is established according to ANSI/ACCA 2 Manual J - 2011 (Residential Load Calculation), ASHRAE handbooks or other equivalent design software or methods.

2. Duct systems are sized according to ANSI/ACCA 1 Manual D - 2014 (Residential Duct Systems), ASHRAE handbooks or other equivalent design software or methods.

3. Select heating and cooling equipment according to ANSI/ACCA 3 Manual S - 2014 (Residential Equipment Selection), or other equivalent design software or methods.Exception: Use of alternate design temperatures necessary to ensure the system functions are acceptable. TABLE 4.504.1 - ADHESIVE VOC LIMIT1,2 (Less Water and Less Exempt Compounds in Grams per Liter) ARCHITECTURAL APPLICATIONS VOC LIMIT INDOOR CARPET ADHESIVES 50 CARPET PAD ADHESIVES 50 OUTDOOR CARPET ADHESIVES 150 WOOD FLOORING ADHESIVES 100 RUBBER FLOOR ADHESIVES 60 SUBFLOOR ADHESIVES 50 CERAMIC TILE ADHESIVES 65 VCT & ASPHALT TILE ADHESIVES 50 DRYWALL & PANEL ADHESIVES 50 COVE BASE ADHESIVES 50 MULTIPURPOSE CONSTRUCTION ADHESIVE 70 STRUCTURAL GLAZING ADHESIVES 100 SINGLE-PLY ROOF MEMBRANE ADHESIVES 250 OTHER ADHESIVES NOT LISTED 50 SPECIALTY APPLICATIONS PVC WELDING 510 CPVC WELDING 490 ABS WELDING 325 PLASTIC CEMENT WELDING 250 ADHESIVE PRIMER FOR PLASTIC 550 CONTACT ADHESIVE 80 SPECIAL PURPOSE CONTACT ADHESIVE 250 STRUCTURAL WOOD MEMBER ADHESIVE 140 TOP & TRIM ADHESIVE 250 SUBSTRATE SPECIFIC APPLICATIONS METAL TO METAL 30 PLASTIC FOAMS 50 POROUS MATERIAL (EXCEPT WOOD) 50 WOOD 30 FIBERGLASS 80 1. IF AN ADHESIVE IS USED TO BOND DISSIMILAR SUBSTRATES TOGETHER, THE ADHESIVE WITH THE HIGHEST VOC CONTENT SHALL BE ALLOWED. 2. FOR ADDITIONAL INFORMATION REGARDING METHODS TO MEASURE THE VOC CONTENT SPECIFIED IN THIS TABLE, SEE SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT RULE 1168. TABLE 4.504.2 - SEALANT VOC LIMIT (Less Water and Less Exempt Compounds in Grams per Liter) SEALANTS VOC LIMIT ARCHITECTURAL 250 MARINE DECK 760 NONMEMBRANE ROOF 300 ROADWAY 250 SINGLE-PLY ROOF MEMBRANE 450 OTHER 420 SEALANT PRIMERS ARCHITECTURAL NON-POROUS 250 POROUS 775 MODIFIED BITUMINOUS 500 MARINE DECK 760 OTHER 750 TABLE 4.504.5 - FORMALDEHYDE LIMITS1 MAXIMUM FORMALDEHYDE EMISSIONS IN PARTS PER MILLION PRODUCT CURRENT LIMIT HARDWOOD PLYWOOD VENEER CORE 0.05 HARDWOOD PLYWOOD COMPOSITE CORE 0.05 PARTICLE BOARD 0.09 MEDIUM DENSITY FIBERBOARD 0.11 THIN MEDIUM DENSITY FIBERBOARD2 0.13 1. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIF. AIR RESOURCES BOARD, AIR TOXICS CONTROL MEASURE FOR COMPOSITE WOOD AS TESTED IN ACCORDANCE WITH ASTM E 1333. FOR ADDITIONAL INFORMATION, SEE CALIF. CODE OF REGULATIONS, TITLE 17, SECTIONS 93120 THROUGH 93120.12. 2. THIN MEDIUM DENSITY FIBERBOARD HAS A MAXIMUM THICKNESS OF 5/16" (8 MM). TABLE 4.504.3 - VOC CONTENT LIMITS FOR ARCHITECTURAL COATINGS2,3 GRAMS OF VOC PER LITER OF COATING, LESS WATER & LESS EXEMPT COMPOUNDS COATING CATEGORY VOC LIMIT FLAT COATINGS 50 NON-FLAT COATINGS 100 NONFLAT-HIGH GLOSS COATINGS 150 SPECIALTY COATINGS ALUMINUM ROOF COATINGS 400 BASEMENT SPECIALTY COATINGS 400 BITUMINOUS ROOF COATINGS 50 BITUMINOUS ROOF PRIMERS 350 BOND BREAKERS 350 CONCRETE CURING COMPOUNDS 350 CONCRETE/MASONRY SEALERS 100 DRIVEWAY SEALERS 50 DRY FOG COATINGS 150 FAUX FINISHING COATINGS 350 FIRE RESISTIVE COATINGS 350 FLOOR COATINGS 100 FORM-RELEASE COMPOUNDS 250 GRAPHIC ARTS COATINGS (SIGN PAINTS) 500 HIGH TEMPERATURE COATINGS 420 INDUSTRIAL MAINTENANCE COATINGS 250 LOW SOLIDS COATINGS1 120 MAGNESITE CEMENT COATINGS 450 MASTIC TEXTURE COATINGS 100 METALLIC PIGMENTED COATINGS 500 MULTICOLOR COATINGS 250 PRETREATMENT WASH PRIMERS 420 PRIMERS, SEALERS, & UNDERCOATERS 100 REACTIVE PENETRATING SEALERS 350 RECYCLED COATINGS 250 ROOF COATINGS 50 RUST PREVENTATIVE COATINGS 250 SHELLACS CLEAR 730 OPAQUE 550 SPECIALTY PRIMERS, SEALERS & UNDERCOATERS 100 STAINS 250 STONE CONSOLIDANTS 450 SWIMMING POOL COATINGS 340 TRAFFIC MARKING COATINGS 100 TUB & TILE REFINISH COATINGS 420 WATERPROOFING MEMBRANES 250 WOOD COATINGS 275 WOOD PRESERVATIVES 350 ZINC-RICH PRIMERS 340 1. GRAMS OF VOC PER LITER OF COATING, INCLUDING WATER & EXEMPT COMPOUNDS 2. THE SPECIFIED LIMITS REMAIN IN EFFECT UNLESS REVISED LIMITS ARE LISTED IN SUBSEQUENT COLUMNS IN THE TABLE. 3. VALUES IN THIS TABLE ARE DERIVED FROM THOSE SPECIFIED BY THE CALIFORNIA AIR RESOURCES BOARD, ARCHITECTURAL COATINGS SUGGESTED CONTROL MEASURE, FEB. 1, 2008. MORE INFORMATION IS AVAILABLE FROM THE AIR RESOURCES BOARD. DIVISION 4.5 ENVIRONMENTAL QUALITY (continued) 4.504.3 CARPET SYSTEMS. All carpet installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.1 Carpet cushion. All carpet cushion installed in the building interior shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. https://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.3.2 Carpet adhesive. All carpet adhesive shall meet the requirements of Table 4.504.1. 4.504.4 RESILIENT FLOORING SYSTEMS. Where resilient flooring is installed , at least 80% of floor area receiving resilient flooring shall meet the requirements of the California Department of Public Health, "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers," Version 1.2, January 2017 (Emission testing method for California Specification 01350) See California Department of Public Health's website for certification programs and testing labs. hhtps://www.cdph.ca.gov/Programs/CCDPHP/DEODC/EHLB/IAQ/Pages/VOC.aspx. 4.504.5 COMPOSITE WOOD PRODUCTS. Hardwood plywood, particleboard and medium density fiberboard composite wood products used on the interior or exterior of the buildings shall meet the requirements for formaldehyde as specified in ARB's Air Toxics Control Measure for Composite Wood (17 CCR 93120 et seq.), by or before the dates specified in those sections, as shown in Table 4.504.5 4.504.5.1 Documentation. Verification of compliance with this section shall be provided as requested by the enforcing agency. Documentation shall include at least one of the following: 1. Product certifications and specifications. 2. Chain of custody certifications. 3. Product labeled and invoiced as meeting the Composite Wood Products regulation (see CCR, Title 17, Section 93120, et seq.). 4. Exterior grade products marked as meeting the PS-1 or PS-2 standards of the Engineered Wood Association, the Australian AS/NZS 2269, European 636 3S standards, and Canadian CSA 0121, CSA 0151, CSA 0153 and CSA 0325 standards. 5. Other methods acceptable to the enforcing agency. DISCLAIMER:THIS DOCUMENT IS PROVIDED AND INTENDED TO BE USED AS A MEANS TO INDICATE AREAS OF COMPLIANCE WITH THE CALIFORNIA GREEN BUILDING STANDARDS (CALGREEN) CODE. DUE TO THE VARIABLES BETWEEN BUILDING DEPARTMENT JURISDICTIONS, THIS CHECKLIST IS TO BE USED ON AN INDIVIDUAL PROJECT BASIS AND MAY BE MODIFIED BY THE END USER TO MEET THOSE INDIVIDUAL NEEDS. THE END USER ASSUMES ALL RESPONSIBILITY ASSOCIATED WITH THE USE OF THIS DOCUMENT, INCLUDING VERIFICATION WITH THE FULL CODE.

Y N/A RESPON.

Y N/A
Y N/A
Y N/A PARTY RESPON. PARTY RESPON. PARTY RESPON. PARTY 2022 CALIFORNIA GREEN BUILDING STANDARDS CODE RESIDENTIAL MANDATORY MEASURES, SHEET 2 (July 2024 Supplement) Y = YES N/A = NOT APPLICABLE RESPON. PARTY = RESPONSIBLE PARTY (ie: ARCHITECT, ENGINEER, OWNER, CONTRACTOR, INSPECTOR ETC.) PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 3/4/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 CAL-GREEN RESIDENTIAL MEASURES CAL GREEN COMPLIANCE A0.3.1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/8/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 ENERGY REPORTS - PLANS 1 AND 2 ENERGRY REPORTS - PLANS 1 AND 2 A0.9 1 243
5 68
91012 13141615 11
7 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/8/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 ENERGRY REPORTS - PLANS 3 AND 4 A0.9.1 ENERGY REPORTS - PLANS 3 AND 4 1 243
5 68
91012 13141615 11
7 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/8/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 ENERGRY REPORTS - PLANS 3 AND 4 A0.9.2 ENERGY REPORTS - PLANS 3 AND 417 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/8/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 ENERGRY REPORTS - PLANS 5 AND 6 A0.9.4 ENERGY REPORTS - PLANS 5 AND 617 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/8/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 ENERGRY REPORTS - PLAN 7 A0.9.5 ENERGY REPORTS - PLAN 7 1 243
5 68
91012 13141615 11
7 PROJECT TABULATIONS PROJECT DATA A1.1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 7/20/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 UNIT AREA BREAKDOWNS: UNIT MIX AND SQUARE FOOTAGE PER BUILDING TYPE UNIT PLAN BEDROOM COUNTS: BUILDING ALLOWABLE AREAS: C.B.C. TABLES (FOR REFERENCE) Note: UL= Unlimited; NP= Not Permited; NS= Building not equipped throughout with an automatic sprinkler system; S= Building equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1; S13R= Building equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2; S13D= Building equipped with an automatic sprinkler system installed in accordance with Section 903.3.1.3. a. See Chapter 4 and 5 for specific exceptions to the allowable height in this chapter. b. See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies. c; d; e; f; g. Information not included. h. New Group R occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6. i. In other than Group A, E, H, I, L, and R occupancies, high-rise buildings, and other applications listed in Section 1.11 regulated by the Office of the State Fire Marshal, the S increases for height and stories in Table 504.3 and 504.4 are permitted in addition to the S area increase in accordance with Table 506.2. 2022 CBC TABLE 504.3 ALLOWABLE BUILDING HEIGHT IN FEET ABOVE GRADE PLANE (EXCERPT) 2022 CBC TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES FOR SPRINKLERED BUILDINGS (HOURS) (EXCERPT) a. See Section 420. b. The required separation from areas used only for private or pleasure vehicles shall be reduced by 1 hour but to not less than 1 hour. c. See Sections 406.3.2 and 406.6.4. d. information not included. e. See Section 422.2 for ambulatory care facilities. f. [SFM] Group I and F1 occupancies and Group R-2.1 and F-1 occupancies shall have a 3 hour separation. h. [SFM] Commercial kitchens not associated with cafeterias and similar dining facilities in Group I-2 and Group R-2.1 shall have a 2-hour separation and shall be protected by an automatic sprinkler system.

Note: UL= Unlimited; NP= Not Permited; NS= Building not equipped throughout with an automatic sprinkler system; S= Building equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1; S13R= Building equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2; S13D= Building equipped with an automatic sprinkler system installed in accordance with Section 903.3.1.3. a. See Chapter 4 and 5 for specific exceptions to the allowable height in this chapter. b. See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies. c; d; e; f; g. Information not included.
h. New Group R occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6.i. See Section 408.1.2 for specific exceptions to construction type, allowable building areas and allowable heights. j. In other than Group A, E, H, I, L, and R occupancies, high-rise buildings, and other applications listed in Section 1.11 regulated by the Office of the State Fire Marshal, the S increases for height and stories in Table 504.3 and 504.4 are permitted in addition to the S area increase in accordance with Table 506.2. 2022 CBC TABLE 504.4 ALLOWABLE NUMBER OF STORIES ABOVE GRADE PLANE (EXCERPT) Note: UL= Unlimited; NP= Not Permited; NS= Building not equipped throughout with an automatic sprinkler system; S1= Buildings a maximum of one story above grade plane equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1; SM= Buildings two or more stories above grade plane equipped throughout with an automatic sprinkler system installed in accordance withSection 903.3.1.1; S13R= Building equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.2; S13D= Building equipped with an automatic sprinkler system installed in accordance with Section 903.3.1.3. a. See Chapter 4 and 5 for specific exceptions to the allowable height in this chapter. b. See Section 903.2 for the minimum thresholds for protection by an automatic sprinkler system for specific occupancies. c. Information not included. d. The NS value is only for use in evaluation of existing building height in accordance with the California Existing Building Code. e. Information not included. f. Information not included. g. Information not included.h. New Group R occupancies are required to be protected by an automatic sprinkler system in accordance with Section 903.2.6.i. In other than Group A, E, H, I, L, and R occupancies, high-rise buildings, and other applications listed in Section 1.11 regulated by the Office of the State Fire Marshal, the S increases for height and stories in Table 504.3 and 504.4 are permitted in addition to the S area increase in accordance with Table 506.2. j. Information not included. 2022 CBC TABLE 506.2 ALLOWABLE AREA FACTOR (At = NS, S1, S13R, or SM, as applicable) IN SQUARE FEET (EXCERPT) 2022 CBC TABLE 601 FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) (EXCERPT) a. a. Roof supports: Fire-resistance ratings of primary structural frame and bearing walls are permitted to be reduced by 1 hour where supporting a roof only. b. 1. Except in Group A, E, F-1, H, I, L, M, R-1, R-2, R-2.1 and S-1 occupancies, high-rise buildings, and other applications listed in Section 1.11 regulated by the Office of the State Fire Marshal, fire protection of structural members in roof construction shall not be required, including protection of primary structural frame members, roof framing and decking where every part of the roof constructionis 20 feet or more above any floor immediately below. Fire-retardant- treated wood members shall be allowed to be used for suchunprotected members.

2. For Group A, E, I, L, R-1, R-2 and R-2.1 occupancies, high-rise buildings, and other applications listed in Section 1.11 regulated by the Office of the State Fire Marshal, fire protection of members other than the primary structural frame shall not be required, including protection of roof framing and decking where every part of the roof construction is 20 feet or more above any floor immediately below.

Fire-retardant-treated wood members shall be allowed to be used for such unprotected members.

3. One-story portions of Group A and E assembly occupancies the roof-framing system of Type II A or Type III A construction may be of unprotected construction when such roof-framing system is open to the assembly area and does not contain concealed spaces. c. In all occupancies, heavy timber complying with Section 2304.11 shall be allowed for roof construction, including primary structural frame members, where a 1-hour or less fire-resistance rating is required. d. Not less than the fire-resistance rating required by other sections of this code. e. Not less than the fire-resistance rating based on fire separation distance (see Table 705.5). f. Not less than the fire-resistance rating as referenced in Section 704.10. 2022 CBC TABLE 1004.5 MAXIMUM FLOOR AREA ALLOWANCES PER OCCUPANT PROJECT SUMMARY AND ANALYSIS DEFERRED SUBMITTALS APPLICABLE CODES 1. PROJECT SUMMARY: 2. BUILDING ANALYSIS: ··· PARKING PROVIDED: NOTES: 1. PER C.B.C. 4.106.4.2.2, ITEM 2.b., 10% OF UNASSIGNED/ GUEST STALLS ARE REQUIRED TO BE EV. PROJECT IS PROVIDING (2) TWO EV STALLS (17 U/G STALLS x .10 = 1.7 OR (2) TWO). SEE SITE PLAN FOR LOCATIONS.

LEGEND H.C. ACCESSIBLE FEC FEC +XX.XX" T.O.S. T.O.P. T.O.C. XXX 159' SD S/CMD UNIT 101 FW #1 KB VBCR GA FIRE MANUAL ASSEMBLIES PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/7/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 LEGENDS A1.5 UNIT KEY NOTES - NON ACCESSIBLE U NITS KEY NOTES ARE FOR IDENTIFICATION PURPOSES ONLY. FOR MORE DETAILED INFORMATION PERTAINING TO ITEMS LISTED BELOW, SEE INTERIOR DESIGN DRAWINGS AND PROJECT SPECIFICATIONS. SEE "UNIT KEY NOTES - ACCESSIBLE UNITS (11A OR 11B)" FOR UNITS THAT ARE REQUIRED TO COMPLY WITH ACCESSIBILITY. SEE PLANS AND PROJECT DATA FOR LOCATIONS. KEY NOTES UNIT KEY NOTES - ACCESSIBLE UNITS (11B - MOBILITY) KEY NOTES ARE FOR IDENTIFICATION PURPOSES ONLY. FOR MORE DETAILED INFORMATION PERTAINING TO ITEMS LISTED BELOW, SEE INTERIOR DESIGN DRAWINGS AND PROJECT SPECIFICATIONS. SEE A0.2.10 SHEETS FOR DETAILED UNIT ACCESSIBILITY REQUIREMENTS FOR GROUND FLOOR UNITS THAT ARE DESIGNATED AS MOBILITY UNITS. SEE "UNIT KEY NOTES - NON ACCESSIBLE UNITS" FOR UNITS AND LEVELS THAT ARE NOT REQUIRED TO COMPLY WITH ACCESSIBILITY.

Joseph Montoya
Tuesday, September 08, 2026 10:41:28 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A1.6_KEYNOTES.DWG PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 ######## #### BUILDING COMPOSITE GENERAL NOTES ROOF GENERAL NOTES ” ” ” ” ” … … ” ” EXTERIOR ELEVATION GENERAL NOTES ” ” ” ” ” “ ” ” ” SECTION NOTES: SECTION GENERAL NOTES “ ” “ ” … ASSEMBLY NOTES ” “ ” ” … “ ” “ ” … ” PARTY WALL, FLOOR CEILING AND ROOF ASSEMBLY NOTES: MILDEW PREEMPTION: ” … … ” ” … … ” ” ” ” ” … PLUMBING INSTALLATION: PENETRATIONS: PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 4/7/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 NOTES A1.7 S S S
S S S
S S
HC
VAN

ERBES ROAD
E. HILLCREST DRIVE

PRIVATE DRIVEWAY D
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM
ELEC. ROOM

PRIVATE DRIVEWAY C

PRIVATE DRIVEWAY B
PRIVATE DRIVEWAY A BUILDING TYPE B BLDG. #4 BUILDING TYPE C BLDG. #3 BUILDING TYPE D BLDG. #2 BUILDING TYPE B BLDG. #1 BUILDING TYPE B BLDG. #8 BUILDING TYPE A BLDG. #7 BUILDING TYPE D BLDG. #6 BUILDING TYPE A BLDG. #5 ELEC. ROOM
HC
VAN PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 7/24/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 ARCHITECTURAL SITE PLAN
1 ARCHITECTURAL SITE PLAN A2.1
W.I.C. 9'-0" CLG. HT. W.I.C. 9'-0" CLG. HT. BEDROOM #1 9'-0" CLG. HT. BEDROOM #1 9'-0" CLG. HT. LAUNDRY 9'-0" CLG. HT. LAUNDRY 9'-0" CLG. HT. BATH #2 9'-0" CLG. HT. BATH #2 9'-0" CLG. HT. LIVING ROOM 9'-0" CLG. HT. BATH #1 7'-8" CLG. HT. BATH #1 9'-0" CLG. HT. KITCHEN 9'-0" CLG. HT. KITCHEN 9'-0" CLG. HT. LIVING ROOM 9'-0" CLG. HT. DINING 9'-0" CLG. HT. DINING 9'-0" CLG. HT. ENTRY 9'-0" CLG. HT. ENTRY 9'-0" CLG. HT. STORAGE 9'-0" CLG. HT. GARAGE +9'-0" CLG. HT. OR GREATER UNIT 02 UNIT 01 UNIT 01 UNIT 02 UNIT 02 UNIT 01 GARAGE +9'-0" CLG. HT. OR GREATER PORCH FLRG. LIVING ROOM FLRG. W.I.C. FLRG. W.I.C. FLRG. BEDROOM #1 FLRG. BEDROOM #1 FLRG. LAUNDRY FLRG. LAUNDRY FLRG. BATH #1 FLRG. BATH #1 FLRG. BATH #2 FLRG. BATH #2 FLRG. KITCHEN FLRG. KITCHEN FLRG. LIVING ROOM FLRG. DINING FLRG. DINING FLRG. GARAGE FLRG. ENTRY FLRG. ENTRY FLRG. STORAGE FLRG. GARAGE FLRG. UNIT 02 UNIT 01 UNIT 01 UNIT 02 UNIT 02 UNIT 01 PORCH FLRG.

Joseph Montoya
Tuesday, September 08, 2026 10:41:09 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.10_UNIT PLANS_01-02.DWG 2 UNITS 01 & 02 FLOOR PLANS - FIRST FLOOR 14 36 5 UNITS 01 & 02 FLOOR PLANS - THIRD FLOOR UNITS 01 & 02 FLOOR PLANS - SECOND FLOOR UNITS 01 & 02 REFLECTED CEILING PLANS - THIRD FLOOR UNITS 01 & 02 REFLECTED CEILING PLANS - SECOND FLOOR UNITS 01 & 02 REFLECTED CEILING PLANS - FIRST FLOOR GARAGE STORAGEHALL W.I.C. ENTRY GARAGE W.I.C. HALL BATH #1 GARAGE STAIR #1 STAIR #2 STAIR #1 Joseph Montoya
Tuesday, September 08, 2026 10:38:57 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.10_UNIT PLANS_01-02.DWG 2 UNIT 01 STAIR SECTION
1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 UNIT 02 STAIR SECTION UNIT PLANS 01 AND 02 STAIR SECTIONS A3.10.1 UNIT 02 STAIR SECTION 3 LIVING ROOM FLRG. W.I.C. FLRG. W.I.C. FLRG. LAUNDRY FLRG. LAUNDRY FLRG. BATH FLRG. BATH FLRG. BATH #2 FLRG. BATH #2 FLRG. DINING FLRG. DINING FLRG. LIVING ROOM FLRG. BEDROOM #2 FLRG. BEDROOM #1 FLRG. BEDROOM #1 FLRG. BEDROOM #2 FLRG. GARAGE FLRG. ENTRY FLRG. GARAGE FLRG. STORAGE FLRG. ENTRY FLRG. ELECTRICAL ROOM FLRG. W.I.C. FLRG. KITCHEN FLRG. KITCHEN FLRG. UNIT 04 UNIT 03 UNIT 04 UNIT 03 UNIT 04 UNIT 03 PORCH FLRG. LIVING ROOM 9'-0" CLG. HT. W.I.C. 9'-0" CLG. HT. W.I.C. 9'-0" CLG. HT. LAUNDRY 9'-0" CLG. HT.LAUNDRY 9'-0" CLG. HT. BATH #2 9'-0" CLG. HT. BATH #2 9'-0" CLG. HT. DINING 9'-0" CLG. HT. DINING 9'-0" CLG. HT. LIVING ROOM 9'-0" CLG. HT. BEDROOM #2 9'-0" CLG. HT. BEDROOM #1 9'-0" CLG. HT. BEDROOM #1 9'-0" CLG. HT. BEDROOM #2 9'-0" CLG. HT. ENTRY 9'-0" CLG. HT. STORAGE 9'-0" CLG. HT. ENTRY 9'-0" CLG. HT. ELECTRICAL ROOM 9'-0" CLG. HT. ROOF W.I.C. 9'-0" CLG. HT. KITCHEN 9'-0" CLG. HT. KITCHEN 9'-0" CLG. HT. UNIT 04 UNIT 03 UNIT 04 UNIT 03 UNIT 04 UNIT 03 BATH #1 7'-8" CLG. HT. BATH #1 7'-8" CLG. HT. GARAGE +9'-0" CLG. HT. OR GREATER GARAGE +9'-0" CLG. HT. OR GREATER ROOF Joseph Montoya
Tuesday, September 08, 2026 10:41:34 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.20_UNIT PLANS_03-04.DWG 2 UNITS 03 & 04 FLOOR PLANS - FIRST FLOOR 14 36 5 UNITS 03 & 04 FLOOR PLANS - THIRD FLOOR UNITS 03 & 04 FLOOR PLANS - SECOND FLOOR UNITS 03 & 04 REFLECTED CEILING PLANS - THIRD FLOOR UNITS 03 & 04 REFLECTED CEILING PLANS - SECOND FLOOR UNITS 03 & 04 REFLECTED CEILING PLANS - FIRST FLOOR LIVING ROOM FLRG. BATH FLRG. BEDROOM #1 FLRG. DECK FLRG. GARAGE HALL W.I.C. STAIR #2 ELECTRICAL ROOM STAIR #1 W.I.C. HALL UNIT 04 UNIT 03 UNIT 04 GARAGE STAIR #1 UNIT 03 Joseph Montoya
Tuesday, September 08, 2026 10:38:11 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.20_UNIT PLANS_03-04.DWG 2 UNIT 04 FLOOR PLAN (REV.) - BUILDING #5 SECOND FLOOR 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 3 UNIT 04, BLDG. 5 FLOOR PLAN, UNIT 03-04 STAIR SECTIONS A3.20.1 UNIT 04 FLOOR PLAN (REV.) - BUILDING #5 THIRD FLOOR UNIT 04 STAIR SECTION 6 UNIT 03 STAIR SECTION 5 UNIT 03 STAIR SECTION 4 GARAGE FLRG. ENTRY FLRG. GARAGE FLRG. FLEX FLRG. ENTRY FLRG. BATH #1 FLRG. BATH #1 FLRG. BATH #2 FLRG. BATH #3 FLRG. BATH #3 FLRG. BATH #2 BATH #3 FLRG. FLRG. LAUNDRY FLRG. LAUNDRY FLRG. BEDROOM #1 FLRG. BEDROOM #1 FLRG. BEDROOM #3 FLRG. BEDROOM #3 FLRG. BEDROOM #2 FLRG. BEDROOM #2 FLRG. W.I.C. FLRG. KITCHEN FLRG. KITCHEN FLRG. DINING FLRG. DINING FLRG. LIVING ROOM FLRG. LIVING ROOM FLRG. UNIT 05 UNIT 06 UNIT 05 UNIT 05 UNIT 06 UNIT 06 PORCH FLRG. PORCH FLRG. ENTRY 9'-0" CLG. HT. ENTRY 9'-0" CLG. HT. LAUNDRY 9'-0" CLG. HT. LAUNDRY 9'-0" CLG. HT. BATH #1 9'-0" CLG. HT. BATH #2 9'-0" CLG. HT. BATH #3 9'-0" CLG. HT. BATH #3 9'-0" CLG. HT. BATH #2 BATH #3 9'-0" CLG. HT. 9'-0" CLG. HT. FLEX 9'-0" CLG. HT. BATH #1 9'-0" CLG. HT. BEDROOM #1 9'-0" CLG. HT. BEDROOM #1 9'-0" CLG. HT. KITCHEN 9'-0" CLG. HT. KITCHEN 9'-0" CLG. HT. DINING 9'-0" CLG. HT. DINING 9'-0" CLG. HT. LIVING ROOM 9'-0" CLG. HT. LIVING ROOM 9'-0" CLG. HT. BEDROOM #3 9'-0" CLG. HT. BEDROOM #3 9'-0" CLG. HT. BEDROOM #2 9'-0" CLG. HT. BEDROOM #2 9'-0" CLG. HT. W.I.C. 9'-0" CLG. HT. UNIT 05 UNIT 06 UNIT 05 UNIT 06 UNIT 05 UNIT 06 GARAGE +9'-0" CLG. HT. OR GREATER GARAGE +9'-0" CLG. HT. OR GREATER ROOF ROOF PORCH FLRG. PORCH FLRG.

Joseph Montoya
Tuesday, September 08, 2026 10:41:32 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.30_UNIT PLANS_05-06.DWG 2 UNITS 05 & 06 FLOOR PLANS - FIRST FLOOR 14 36 5 UNITS 05 & 06 FLOOR PLANS - THIRD FLOOR UNITS 05 & 06 FLOOR PLANS - SECOND FLOOR UNITS 05 & 06 REFLECTED CEILING PLANS - THIRD FLOOR UNITS 05 & 06 REFLECTED CEILING PLANS - SECOND FLOOR UNITS 05 & 06 REFLECTED CEILING PLANS - FIRST FLOOR STAIR #1 GARAGE BEDROOM #2GARAGE BEDROOM #2 HALL LIVING ROOM HALL LIVING ROOM STAIR #1 Joseph Montoya
Tuesday, September 08, 2026 10:39:17 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.30_UNIT PLANS_05-06.DWG UNIT 05 STAR SECTION 12 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 08/25/23 24101 05/02/22 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
at Thousand Oaks
384 Erbes Road
Thousand Oaks, California UNIT 06 STAIR SECTION UNITS 05-06 STAIR SECTIONS A3.30.1 LAUNDRY FLRG. W.I.C. FLRG. BEDROOM #3 FLRG. GARAGE FLRG. ENTRY FLRG. BATH #1 FLRG. BEDROOM #4 FLRG. BEDROOM #2 FLRG. BEDROOM #1 FLRG. LIVING ROOM FLRG. KITCHEN FLRG.DINING FLRG. BATH #2 FLRG. BATH #4 FLRG. BATH #3 FLRG. W.I.C. FLRG. UNIT 07 UNIT 07 UNIT 07 PORCH FLRG. LAUNDRY 7'-8" CLG. HT. W.I.C. 9'-0" CLG. HT. BEDROOM #3 9'-0" CLG. HT. ENTRY 9'-0" CLG. HT. BATH #1 9'-0" CLG. HT. BEDROOM #4 9'-0" CLG. HT. BEDROOM #2 9'-0" CLG. HT. BEDROOM #1 9'-0" CLG. HT. LIVING ROOM 9'-0" CLG. HT. KITCHEN 9'-0" CLG. HT. DINING 9'-0" CLG. HT. BATH #2 7'-8" CLG. HT. BATH #4 9'-0" CLG. HT. BATH #3 9'-0" CLG. HT. W.I.C. 9'-0" CLG. HT. GARAGE +9'-0" CLG. HT. OR GREATER ROOF Joseph Montoya
Tuesday, September 08, 2026 10:40:47 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.40_UNIT PLAN_07.DWG 2 UNIT 07 FLOOR PLAN - FIRST FLOOR 14 36 5 UNIT 07 FLOOR PLAN - THIRD FLOOR UNIT 07 FLOOR PLAN - SECOND FLOOR UNIT 07 REFLECTED CEILING PLAN - THIRD FLOOR UNIT 07 REFLECTED CEILING PLAN - SECOND FLOOR UNIT 07 REFLECTED CEILING PLAN - FIRST FLOOR GARAGE HALL W.I.C. STAIR #1
Joseph Montoya
Tuesday, September 08, 2026 10:40:55 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.40_UNIT PLAN_07.DWG UNIT 07 STAIR SECTION 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 UNIT PLAN 07 STAIR SECTIONS A3.40.1 BATH #2
D
C
B BATH 1 KITCHEN
B
A
TOILET K3486
VITREOUS CHINA TOILET LEIGHTON K3486
A
TOILET K-3486
A BATH #2
D
C
B BATH 1 KITCHEN
A
C
A
TOILET LEIGHTON K-3486
TOILET K-3486
VITREOUS CHINA TOILET LEIGHTON K3486
C
B BATH 1 KITCHEN
B
VITREOUS CHINA TOILET LEIGHTON K-3486 A
A
C
A
VITREOUS CHINA TOILET LEIGHTON K3486 BATH #2
D
C
B
A
VITREOUS CHINA TOILET LEIGHTON K3486
Joseph Montoya
Tuesday, September 08, 2026 10:38:32 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.50_INTERIOR-ELEVS.DWG UNIT 01 INTERIOR ELEVATIONS 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 UNIT 02 INTERIOR ELEVATIONS UNIT 03 INTERIOR ELEVATIONS UNIT 01, 02 AND 03 INTERIOR ELEVATIONS A3.50 2 3
BATH #2
D
C
B
A
VITREOUS CHINA TOILET LEIGHTON K3486
VITREOUS CHINA TOILET LEIGHTON K3486
TOILET K3486 BATH 1 KITCHEN
D
C
B
A
TOILET LEIGHTON K-3486 C KITCHEN
C
B
A BATH #1
D
B
A
VITREOUS CHINA TOILET LEIGHTON K-3486
C
VITREOUS CHINA TOILET LEIGHTON K3486 BATH #2
D
C
B
A BATH #3
D
C
B
A
VITREOUS CHINA TOILET LEIGHTON K-3486
Joseph Montoya
Tuesday, September 08, 2026 10:40:06 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.50_INTERIOR-ELEVS.DWG UNIT 04 INTERIOR ELEVATIONS 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 UNIT 05 INTERIOR ELEVATIONS UNITS 04 AND 05 INTERIOR ELEVATIONS A3.50.1 2 K
3486 KITCHEN
C
B
A BATH #2 D
C
B
A BATH #1
TOILET LEIGHTON K-3486
TOILET K-3486
VITREOUS CHINA TOILET LEIGHTON K3486 BATH #4
D
C
B
A BATH #3
D
C
B
A
TOILET K-3486
TOILET K3486
TOILET K3486 BATH #2
C
B
A
VITREOUS CHINA TOILET LEIGHTON K3486
D BATH #3
C
B BATH #4
D
C
B
A
D
A
VITREOUS CHINA TOILET LEIGHTON K-3486
VITREOUS CHINA TOILET LEIGHTON K3486
TOILET K3486 BATH #1
D

B KITCHEN & ISLAND
C
B
D
A
C
A
VITREOUS CHINA TOILET LEIGHTON K3486
VITREOUS CHINA TOILET LEIGHTON K3486
A
Joseph Montoya
Tuesday, September 08, 2026 10:39:27 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A3.50_INTERIOR-ELEVS.DWG UNIT 06 INTERIOR ELEVATIONS 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 UNIT 07 INTERIOR ELEVATIONS UNITS 06 AND 07 INTERIOR ELEVATIONS A3.50.2 2 A
B
C
D D1
E
F
G
H H1
Joseph Montoya
Tuesday, September 08, 2026 10:37:55 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A4.1_DOOR SCHEDULE.DWG DOOR TYPES DOOR NOTES DOOR HARDWARE UNIT DOORS GENERAL NOTES: HARDWARE NOTES: DOOR SCHEDULE PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123
BUILDING DOORS DOOR SCHEDULE A4.1
1 2
3 Joseph Montoya
Tuesday, September 08, 2026 10:39:51 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A4.2_WINDOW SCHEDULE.DWG - WINDOW NOTES SAFETY GLAZING CODE REQUIREMENTS (C.B.C. 2406) WINDOW SCHEDULE UNIT WINDOWS PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 WINDOW TYPES MATERIAL & CONSTRUCTION METHODS FOR WILDFIRE EXPOSURE (C.B.C 708A) WINDOW SCHEDULE 3 2 1 A4.2
UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 7 UNIT PLAN 7 UNIT PLAN 4 UNIT PLAN 3 UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 7 UNIT PLAN 7 UNIT PLAN 4 UNIT PLAN 3 UNIT PLAN 3UNIT PLAN 4 UNIT PLAN 7 UNIT PLAN 7 UNIT PLAN 4UNIT PLAN 3 BUILDING-A SLAB PLAN 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 5/27/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-A SECOND FLOOR PLAN BUILDING-A THIRD FLOOR PLAN 4 2 3 BUILDING-A FIRST FLOOR PLAN BUILDING-A SLAB, FIRST, SECOND, THIRD FLOOR PLANS A5.10 ROOF AREA '7A' VENTILATION CALCULATIONS PLAN 7 * ROOF AREA '7B' ROOF AREA '7A' VENTILATION CALCULATIONS PLAN 7 * ROOF AREA '7B' ROOF AREA '3A' VENTILATION CALCULATIONS PLAN 3 * VENTILATION CALCULATIONS PLAN 3 ROOF AREA '3B' ROOF AREA '3C' VENTILATION CALCULATIONS PLAN 4 * VENTILATION CALCULATIONS PLAN 4 ROOF AREA '4A' ROOF AREA '4B' ROOF AREA '4C' ROOF AREA '3A' VENTILATION CALCULATIONS PLAN 3 * VENTILATION CALCULATIONS PLAN 3 ROOF AREA '3B' ROOF AREA '3C' VENTILATION CALCULATIONS PLAN 4 * VENTILATION CALCULATIONS PLAN 4 ROOF AREA '4A' ROOF AREA '4B' ROOF AREA '4C' BUILDING-7A ROOF PLAN 1 BUILDING-A ROOF PLAN BUILDING-5A ROOF PLAN 2 A5.11 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-7A (FRONT) EXTERIOR ELEVATION
1 BUILDING-7A (REAR) EXTERIOR ELEVATION
2 BUILDING-7A (LEFT SIDE) EXTERIOR ELEVATION
3 BUILDING-7A (RIGHT SIDE) EXTERIOR ELEVATION
4 BUILDING-A ELEVATIONS A5.12
BUILDING-5A (FRONT STEPPED) EXTERIOR ELEVATION
1 BUILDING-5A (REAR STEPPED) EXTERIOR ELEVATION
2 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-5A (LEFT SIDE STEPPED) EXTERIOR ELEVATION
3 BUILDING-5A (RIGHT SIDE STEPPED) EXTERIOR ELEVATION
4 BUILDING-A ELEVATIONS (STEPPED) A5.12.1
PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-7A SECTION 1 BUILDING-5A SECTION 2 BUILDING-A SECTIONS A5.13 UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 5 UNIT PLAN 6 UNIT PLAN 7 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 4 UNIT PLAN 3 BUILDING-B SLAB PLAN 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-B FIRST FLOOR PLAN
2 BUILDING-B SLAB, FIRST FLOOR PLANS A5.20
UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 5 UNIT PLAN 6 UNIT PLAN 7 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 5 UNIT PLAN 6 UNIT PLAN 7 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 3 UNIT PLAN 4 BUILDING-B SECOND FLOOR PLAN 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-B THIRD FLOOR PLAN
2 BUILDING-B SECOND, THIRD FLOOR PLANS A5.20.1
ROOF AREA '7A' VENTILATION CALCULATIONS PLAN 7 * ROOF AREA '7B' ROOF AREA '6A' VENTILATION CALCULATIONS PLAN 6 * ROOF AREA '7A' VENTILATION CALCULATIONS PLAN 7 * ROOF AREA '6A' ROOF AREA '7B' VENTILATION CALCULATIONS PLAN 6 * VENTILATION CALCULATIONS PLAN 4 * VENTILATION CALCULATIONS PLAN 4 ROOF AREA '4A' ROOF AREA '4B' ROOF AREA '4C' ROOF AREA '3A' VENTILATION CALCULATIONS PLAN 3 * VENTILATION CALCULATIONS PLAN 3 ROOF AREA '3B' ROOF AREA '3C' ROOF AREA '5A' VENTILATION CALCULATIONS PLAN 5 * VENTILATION CALCULATIONS PLAN 5 ROOF AREA '5B' VENTILATION CALCULATIONS PLAN 4 * VENTILATION CALCULATIONS PLAN 4 ROOF AREA '4A' ROOF AREA '4B' ROOF AREA '4C' ROOF AREA '3A' VENTILATION CALCULATIONS PLAN 3 * VENTILATION CALCULATIONS PLAN 3 ROOF AREA '3B' ROOF AREA '3C' ROOF AREA '5A' VENTILATION CALCULATIONS PLAN 5 * VENTILATION CALCULATIONS PLAN 5 ROOF AREA '5B' BUILDINGS-4B & 8B ROOF PLAN 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-1B ROOF PLAN 2 BUILDING-B ROOF PLAN A5.21 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-4B & 8B (FRONT) EXTERIOR ELEVATION 1 BUILDING-4B & 8B (REAR) EXTERIOR ELEVATION 2 BUILDING-B ELEVATIONS (FRONT & REAR) A5.22 12 - 3 - 4 BUILDING-4B & 8B (LEFT SIDE) EXTERIOR ELEVATION BUILDING-4B & 8B (RIGHT SIDE) EXTERIOR ELEVATION PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123BUILDING-B ELEVATIONS (LEFT & RIDE SIDE) A5.22.1 BUILDING-1B (FRONT STEPPED) EXTERIOR ELEVATION 1 BUILDING-1B (REAR STEPPED) EXTERIOR ELEVATION 2 BUILDING-B ELEVATIONS (FRONT & REAR)-STEPPED A5.22.2 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 12 - 3 - 4 BUILDING-1B (LEFT SIDE STEPPED) EXTERIOR ELEVATION BUILDING-1B (RIGHT SIDE STEPPED) EXTERIOR ELEVATION BUILDING-B ELEVATIONS (STEPPED) A5.22.3 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-4B & 8B SECTION 1 BUILDING-1B SECTION 2 BUILDING-B SECTIONS A5.23 UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 5 UNIT PLAN 6 UNIT PLAN 7 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 4 UNIT PLAN 3 UNIT PLAN 6 UNIT PLAN 5 BUILDING-3C SLAB PLAN 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-3C FIRST FLOOR PLAN
2 BUILDING-C SLAB, FIRST FLOOR PLANS A5.30
UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 5 UNIT PLAN 6 UNIT PLAN 7 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 4UNIT PLAN 3 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 5 UNIT PLAN 6 UNIT PLAN 7 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 4 UNIT PLAN 3 UNIT PLAN 6 UNIT PLAN 5 BUILDING-C SECOND FLOOR PLAN 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-C THIRD FLOOR PLAN
2 BUILDING-C SECOND, THIRD FLOOR PLANS A5.30.1
ROOF AREA '7A' VENTILATION CALCULATIONS PLAN 7 * ROOF AREA '7B' ROOF AREA '6A' VENTILATION CALCULATIONS PLAN 6 * VENTILATION CALCULATIONS PLAN 4 * VENTILATION CALCULATIONS PLAN 4 ROOF AREA '4A' ROOF AREA '4B' ROOF AREA '4C' ROOF AREA '3A' VENTILATION CALCULATIONS PLAN 3 * VENTILATION CALCULATIONS PLAN 3 ROOF AREA '3B' ROOF AREA '3C' ROOF AREA '5A' VENTILATION CALCULATIONS PLAN 5 * VENTILATION CALCULATIONS PLAN 5 ROOF AREA '5B' BUILDING-3C ROOF PLAN 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 - 2 BUILDING-C ROOF PLAN A5.31 BUILDING-3C (FRONT) EXTERIOR ELEVATION 1 BUILDING-3C (REAR) EXTERIOR ELEVATION 2 BUILDING-C ELEVATIONS (FRONT & REAR) A5.32 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 1 2
-
3 -
4 BUILDING-3C (LEFT SIDE) EXTERIOR ELEVATION BUILDING-3C (RIGHT SIDE) EXTERIOR ELEVATION BUILDING-C ELEVATIONS (LEFT & RIGHT SIDE) A5.32.1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123
PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-3C SECTION 1 BUILDING-C SECTIONS A5.33 UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 5 UNIT PLAN 6 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 4 UNIT PLAN 3 UNIT PLAN 1 UNIT PLAN 2 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 2 UNIT PLAN 1 Joseph Montoya
Tuesday, September 08, 2026 10:38:41 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A5.40_BLDG D FIRST-SECOND-THIRD-ROOF.DWG BUILDING-D SLAB PLAN 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-D FIRST FLOOR PLAN
2 BUILDING-D SLAB, FIRST FLOOR PLANS A5.40
UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 5 UNIT PLAN 6 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 4 UNIT PLAN 3 UNIT PLAN 1 UNIT PLAN 2 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 2 UNIT PLAN 1 UNIT PLAN 3 UNIT PLAN 4 UNIT PLAN 5 UNIT PLAN 6 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 4 UNIT PLAN 3 UNIT PLAN 1 UNIT PLAN 2 UNIT PLAN 6 UNIT PLAN 5 UNIT PLAN 2 UNIT PLAN 1 Joseph Montoya
Tuesday, September 08, 2026 10:41:25 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A5.40_BLDG D FIRST-SECOND-THIRD-ROOF.DWG BUILDING-D SECOND FLOOR PLAN 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-D THIRD FLOOR PLAN
2 BUILDING-D SECOND, THIRD FLOOR PLANS A5.40.1
ROOF AREA '1A' VENTILATION CALCULATIONS PLAN 1 * ROOF AREA '2A' ROOF AREA '6A' VENTILATION CALCULATIONS PLAN 6 * VENTILATION CALCULATIONS PLAN 2 * ROOF AREA '1A' VENTILATION CALCULATIONS PLAN 1 * ROOF AREA '2A' ROOF AREA '6A' VENTILATION CALCULATIONS PLAN 6 * VENTILATION CALCULATIONS PLAN 2 * ROOF AREA '5A' VENTILATION CALCULATIONS PLAN 5 * VENTILATION CALCULATIONS PLAN 5 ROOF AREA '5B' VENTILATION CALCULATIONS PLAN 4 * VENTILATION CALCULATIONS PLAN 4 ROOF AREA '4A' ROOF AREA '4B' ROOF AREA '4C' ROOF AREA '3A' VENTILATION CALCULATIONS PLAN 3 * VENTILATION CALCULATIONS PLAN 3 ROOF AREA '3B' ROOF AREA '3C' ROOF AREA '3A' VENTILATION CALCULATIONS PLAN 3 * VENTILATION CALCULATIONS PLAN 3 ROOF AREA '3B' ROOF AREA '3C' VENTILATION CALCULATIONS PLAN 4 * VENTILATION CALCULATIONS PLAN 4 ROOF AREA '4A' ROOF AREA '4B' ROOF AREA '4C' ROOF AREA '5A' VENTILATION CALCULATIONS PLAN 5 * VENTILATION CALCULATIONS PLAN 5 ROOF AREA '5B' Joseph Montoya
Tuesday, September 08, 2026 10:37:52 AM
L:\M3 PROJECTS\2024\24101 DICECCO HILLCREST TH\CD\01_CAD\SHEETS\24101-A5.41_BLDG D ROOF.DWG BUILDING-6D ROOF PLAN 1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-D ROOF PLAN BUILDING-2D ROOF PLAN 2 A5.41 BUILDING-6D (FRONT OVERALL) EXTERIOR ELEVATION 1 BUILDING-6D (FRONT SEGMENT 1) EXTERIOR ELEVATION 2 BUILDING-6D (FRONT SEGMENT 2) EXTERIOR ELEVATION 3 BUILDING-D ELEVATIONS (FRONT) A5.42 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-6D (REAR OVERALL) EXTERIOR ELEVATION 1 BUILDING-6D (REAR SEGMENT 1) EXTERIOR ELEVATION 2 BUILDING-6D (REAR SEGMENT 2) EXTERIOR ELEVATION 3 BUILDING-D ELEVATIONS (REAR) A5.42.1 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 1 2
-
3 -
4 BUILDING-6D (LEFT SIDE) EXTERIOR ELEVATION BUILDING-6D (RIGHT SIDE) EXTERIOR ELEVATION BUILDING-D ELEVATIONS (LEFT & RIGHT SIDE) A5.42.2 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123
BUILDING-2D (FRONT OVERALL) EXTERIOR ELEVATION 1 BUILDING-2D (FRONT SEGMENT 1) EXTERIOR ELEVATION 2 BUILDING-2D (FRONT SEGMENT 2) EXTERIOR ELEVATION 3 BUILDING-D ELEVATIONS (FRONT)-STEPPED A5.42.3 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-2D (REAR SEGMENT 1) EXTERIOR ELEVATION
2 BUILDING-2D (REAR SEGMENT 2) EXTERIOR ELEVATION
3 BUILDING-2D (REAR OVERALL) EXTERIOR ELEVATION
1 BUILDING-D ELEVATIONS (REAR)-STEPPED A5.42.4 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123
1 2
-
3 -
4 BUILDING-2D (LEFT SIDE) EXTERIOR ELEVATION BUILDING-2D (RIGHT SIDE) EXTERIOR ELEVATION BUILDING-D ELEVATIONS (LEFT & RIGHT SIDE)-STEPPED A5.42.5 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123
PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-6D (FRONT OVERALL) SECTION 1 BUILDING-6D (FRONT SEGMENT 1) SECTION 2 BUILDING-6D (FRONT SEGMENT 2) SECTION 3 BUILDING-D SECTIONS A5.43 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 BUILDING-2D (FRONT OVERALL) SECTION 1 BUILDING-2D (FRONT SEGMENT 1) SECTION 2 BUILDING-2D (FRONT SEGMENT 2) SECTION 3 BUILDING-D SECTIONS A5.43.1 PLANS 3 & 4 - BUILDING SECTIONS 1 PLANS 1 & 2 - BUILDING SECTIONS 2 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 UNIT SECTIONS A8.1.1 PLAN 7 - BUILDING SECTIONS 1 PLANS 5 & 6 - BUILDING SECTIONS 2 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 UNIT SECTIONS A8.1.2

WALL SECTION -
7 WALL SECTION -
5 WALL SECTION -
3 WALL SECTION -
1 WALL SECTION -
8 WALL SECTION -
6 WALL SECTION -
4 WALL SECTION -
2 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/13/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 UNIT WALL SECTIONS A8.2.1
ASSIGNED SPOT MARKING RESERVED ### ACCESSIBLE STALL STRIPING 14-4- 13-7- NO PARKING 9FT STALL STRIPING LOADING ZONE MARKINGS NO PARKING RESERVED PARKING VAN ACCESSIBLE MINIMUM FINE $250. ACCESSIBLE STALL SIGN GUEST SPOT MARKINGLINE #2 LINE #3 LINE #1 ASSIGNED EV MARKING CLEAN AIR / VAN POOL / EV AUTOMOBILE FUEL AND ITS BY-PRODUCTS CONTAIN CHEMICALS KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER OR BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM. WARNING HAZARD SIGNUnauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or special license plates issued for persons with disabilities will be towed away at the owner's expense. Towed vehicles may be reclaimed at __________________ __________________ by telephoning __________________ TOW-AWAY SIGNAGE WHEEL STOP BOLLARD - FILLED TYPICAL SECTION A-A TYPICAL PLAN DETECTABLE WARNING AT HAZARDOUS VEHICULAR AREAS TRUNCATED DOMES × DETECTABLE WARNINGS 678 15 10 1311 2016 1412 181917 2345 ACCESSIBLE STALL MARKING 9 2120 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 7/22/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 212121 NON-COMBUSTIBLE DETAILS AD.0.1 TUB TRAP PENETRATION ASSEMBLY 1 HOUR TUB ASSEMBLY TUB ASSEMBLIES & TRAP PENETRATION 15 5 11 6 20 2325 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/7/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 FIRE PROTECTION DETAILS AD.1.15 PIPE ISOLATION AT FLR/CLG JOISTS PIPE ISOLATION AT STUD WALLS PIPING ACOUSTIC ISOLATIONS ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC RATING: MODIFICATIONS: 1 HR EXT. WALL WOOD STUDS/PLASTER ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC RATING: MODIFICATIONS: ROOF/CEILING INTERSECTION PLAN DWELLING UNIT DWELLING UNIT DWELLING UNIT PLUMBING WALL AT UNIT DWELLING UNIT TYPICAL SLAB / FOOTINGS FLOOR/CEILING INTERSECTION UNIT UNIT UNIT UNIT UNIT UNIT ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC RATING: MODIFICATIONS: PLAN 1 HR FIRE PARTITION AT DOUBLE WALL ROOF/ CEILING INTERSECTION UNIT UNIT ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC RATING: MODIFICATIONS: 1 HR INTERIOR WALL FLOOR TO WALL TRANSITION DETAIL UNIT CEILING TO WALL ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC / IIC RATING: MODIFICATIONS: FINISH SURFACE TRANSITION DETAIL AT CARPET FINISH SURFACE TRANSITION DETAIL AT VINYL 1 HR FLOOR/CEILING ASSEMBLY AT UNIT/GARAGE ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC RATING: MODIFICATIONS: 1 HR EXT. WALL WOOD STUD / EXT. SIDING 10 TYP. RECESSED PANEL/CABINET AT INTERIOR WALL RECESSED CABINET 1 HR WALL 1 15 6 15 2423222125 20 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/7/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 FIRE PROTECTION DETAILS AD.1.16 12 16171819 PIPE PENETRATION - METALLIC PIPE PENETRATION - NONMETALLIC WIRE/CABLE PENETRATIONS PIPE PENETRATION - METALLIC PIPE PENETRATION - NONMETALLIC PIPE, WIRE & CABLE PENETRATIONS 1 HR PENETRATION AT OUTLET BOX 14 ALTERNATIVE: 1-HR FLOOR/CEILING AT DECK ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC / IIC RATING: MODIFICATIONS:

ASSEMBLY NOTES” “ ” ” … “ ” “ ” … ” FIREBLOCKING NOTES: PARTY WALL, FLOOR CEILING AND ROOF ASSEMBLY NOTES: MILDEW PREEMPTION: ” … … ” ” … … ” ” ” ” ” … PLUMBING INSTALLATION: PENETRATIONS: NON-RATED PLUMBING BOX AA SECTION A ELEVATION PLAN SECTION A SECTION B PLAN VIEW- CONDITION AT DROP SOFFIT FRAMINGATTIC ATTIC ATTIC ACCESS AT NON-RATED CEILING LIGHT OR DUCT AT ROOF / CEILING ASSEMBLY REGISTER THRU INTERIOR WALL CORRIDOR LIVING SPACE ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC / IIC RATING: MODIFICATIONS: NON-RATED ROOF/CEILING ASSEMBLY - TRUSSES AT INTERIOR ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC / IIC RATING: MODIFICATIONS: NON-RATED ROOF/CEILING ASSEMBLY - TRUSSES AT EXTERIOR 678 15 10 13 25 20 12 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 5/28/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 22232421 ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC RATING: MODIFICATIONS: NON-RATED INTERIOR WALL ASSEMBLY TYPE: CODE DESCRIPTION: FIRE RATING: LISTING: STC RATING: MODIFICATIONS: NON RATED EXTERIOR WALL WOOD STUDS NON-RATED DETAILS AD.1.20 19 14 18 10 5 14 17 15 1920 242225 3 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 5/28/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 EXTERIOR DOOR HEAD/JAMB FIBER CEMENT SIDING DOOR HEAD WHEN EXPOSED TO WEATHER DOOR JAMB EXTERIOR DOOR HEAD/JAMB STUCCO DOOR HEAD WHEN EXPOSED TO WEATHER DOOR JAMB X X X X X X X X X X X X X X X X X X X X X X X DOOR JAMB DOOR HEAD WHEN EXPOSED TO WEATHER H.M. DOOR - FLUSH AT STUCCO DOOR - THRESHOLD @ SLAB ON GRADE @ SLAB ON GRADE
DOOR - THRESHOLD @ DECK
@ EXTERIOR DECK FRAMING
DOOR - THRESHOLD @ CONC. FLOOR
@ CONCRETE SLAB DOOR JAMB DOOR HEAD INTERIOR DOOR HEAD/JAMB 21 11 6 1 23 18 8 ACCESSIBLE GARAGE DR. THRESHOLD STANDARD GARAGE DR. THRESHOLD GARAGE DOOR SLAB, JAMB & HEAD CURB DIMENSIONS JAMB HEAD 16 DOOR DETAILS AD.2.2 WINDOW TRIM DETAILS B. A. E. D. C. 5A AD.2.3 5B AD.2.3 5C AD.2.3 12 AD.2.3 15B AD.2.3 15A AD.2.3 15A AD.2.3 15B AD.2.3 15C AD.2.3 10A AD.2.3 10C AD.2.3 20A AD.2.3 20B AD.2.3 17 AD.2.3 10B AD.2.3 20C AD.2.3 NOT REQUIRED IF THE DOOR IS PROTECTED BY A MINIMUM 30" DEEP EAVE OR SOFFIT THAT IS WITHIN 24" OF THE DOOR HEAD, THE EAVE OR SOFFIT SHALL EXTEND 30" EACH SIDE OF DOOR. 4" 4" 2" S.A.F. REQUIRED ONLY WITH "HEAD FLASHING PROFILE". SECTION BB ROUGH OPENING WIDTH F.F. SECTION AA "L" FLASHING - SEE NOTE #1 AND #2. DOOR OPENING FLASHING INSTALLATION WINDOW - FLUSH @ FIBER CEMENT SIDING A. WINDOW SILL B. WINDOW JAMB C. WINDOW HEAD FLUSH OPENING HEAD FLASHING FLUSH CONDITION HEAD FLASHING PROFILE HEAD FLASHING "L" PROFILE AT STOREFRONT FLUSH CONDITION AT STOREFRONT B. WINDOW JAMB C. WINDOW HEAD WINDOW - DEEP RECESS AT BD. & BATTEN A. WINDOW SILL A WINDOW SILL B. WINDOW JAMB C. WINDOW HEAD WINDOW - FLUSH @ STUCCO TRIM A WINDOW SILL WINDOW - FLUSH @ 9" STUCCO TRIM WINDOW - FLUSH @ FIBER CEMENT BOARD & BATTEN A. WINDOW SILL B. WINDOW JAMB C. WINDOW HEAD WINDOW - FLUSH @ CORNER FIBER CEMENT SIDING A. WINDOW JAMB 15 5 11 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 5/28/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 10 2 WINDOW DETAILS AD.2.3 12 2017 21 16 25 GUARDRAIL TO WALL ATTACHMENT GUARDRAIL TO WALL ATTACHMENT (PLAN VIEW) JUILIETTE RAIL 3D. SECTION 3B- 3C. LEFT SIDE ELEV. 3B. FRONT ELEV. 3D- 3A. PLAN 3E. RIGHT SIDE ELEV. DRIP EDGE @ SOFFIT X X X X X X X X X STUCCO SCREEDS AT SIDEWALK AT GRADE X X X X X X X X X X X X X X X X X X X X X X X X X X X X X GENERAL NOTES: E.P.S. TRIM BAND AT MATERIAL TRANSITION TYPICAL CONTROL JOINT AT NON-FLOOR LINE CONDITION AT FLOOR LINE CONDITION X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X SEPARATE POUR SLAB @ UTILITY CLOSET GARAGE GARAGE 1 HR WALL @ GARAGE CURB (SINGLE & DBL.) GARAGE GARAGE FIBER CEMENT BD. & BATTEN TO FIBER CEMENT SIDING FIBER CEMENT SIDING TO PLASTER (INSIDE CORNERS) X X X X SCREED @ GARAGE SCREED @ DEEPENED FOOTING FIBER CEM SIDING AT SOFFIT VERTICAL BATTEN DETAIL INTERIOR EXTERIOR X X X X X X X X EYEBROW FRAMING OVER ENTRY ENTRY SCREEN FIBER CEMENT LAP SIDING MITERED CORNER VERTICAL FIBER CEM. BD. & BATTEN OUTSIDE CORNER 4325 7 15 17 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 14 86 EXTERIOR DETAILS AD.3.2 10 18161920 22 RAIL TO WALL CONNECTION 25 12 5 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 8/27/26 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123BOARD & BATTEN LAYOUT AD.3.3 BOARD & BATTEN LAYOUT INFORMATION & DETAILS 14 AD.3.2 19 AD.3.2 B. TOWN HOME UNITS 03/04 LEFT & RIGHT SIDE ELEVATIONS A. TOWN HOME UNIT 03 REAR ELEVATION 14 AD.3.2 19 AD.3.2 C. TOWN HOME UNIT 04 FRONT ELEVATION D. TOWN HOME UNIT 06 FRONT ELEVATION 14 AD.3.2 19 AD.3.2 E. TOWN HOME UNIT 07 REAR ELEVATION F. TOWN HOME UNIT 07 (SIDE BY SIDE) REAR ELEVATION 4 321
9710 12 25 20 15 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 4/7/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123
67 19 14 18 13 17 21 16
- 222324
5 STAIR DETAILS (WOOD) AD.4.2 GUARDWALL HANDRAIL AT UNIT WOOD STAIR @ CONC SLAB WOOD STAIR @ FLOOR WOOD STAIR @ LANDING WOOD STAIR @ SKIRT WOOD STAIR TO LANDING / FLOOR WALL PENETRATIONS SECTION PLAN DOWNSPOUT & SPLASH BLOCK VALLEY HIP RIDGE ROOF TO WALL AT SIDE ROOF TO WALL TOP SLOPE RAKE (1-HR RATED) EXTERIOR ALUMINUM GUTTER PIPE PENETRATION PANEL END LAP DETAIL TYPICAL EAVE OVERHANG (1-HR RATED) 52 13 8 1215 191720 2423222125 6 18 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 5/28/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 16 11 7 14 910 4 ROOF DETAILS AD.5.1 4315 1315 16 232125 SOFFIT ABOVE CABINET COUNTERTOP PLAN SECTION ELEVATION BATHROOM SIDE ELEVATION DETAIL 6BACK WALL SIDE WALL @ SHOWER HEAD SURROUND AT TUBSIDE WALL TUB SURROUND - TILE DETAILS SECTION A PLAN A- PLAN 18 PROJECT NAME DRAWN JOB No. SHEET TITLE SHEET No. ARCHITECTURE, INC. reserves their common law copyright in these documents. they are not to be reproduced, copied, changed, nor assigned to a third party without the written consent of this drawing(s) not for construction without architect's stamp and original signature DELTA/DATE ISSUED FOR SHEET DATE 4/7/25 22206 08/05/24 1ST City Submittal DICECCO ARCHITECTURE, INC. DICECCO ARCHITECT CONSULTANT Hillcrest Ownership Housing
384 Erbes Road
Thousand Oaks, California
05/20/25 2ND City Submittal08/21/26 3RD City Submittal08/21/26 Deck Removal 123 22 MISCELLANEOUS DETAILS AD.6.1 24 19 14 2017 12 CDD: 420-78/nk/H:COMMON/City Council/CC Agenda Items/2026/10132026/Amended 78-Unit For-Sale Affordable Housing Project – 384 Erbes Rd. Attach 5 Updated Architectural Plans..pdf

← All documents from this meeting