Attachment B
Station Floor Layouts
USDD.CA_UNCTY.FS31.FSA.DWG design by

A B C D
4 3
2 1
4 2
1 A B C D
3 project building filename date

T H I S D O C U M E N T CONTAINS CONFIDENTIAL A N D P R O P R I E T A R Y

INFORMATION WHICH IS

THE EXCLUSIVE PROPERTY OF US DIGITAL DESIGNS,
I N C . R EP R O D U C T I O N , DISTRIBUTION OR USE BY OTHERS, IN WHOLE OR IN

PART, IS NOT PERMITTED WITHOUT THE WRITTEN
AUTHORIZATION FROM US DIGITAL DESIGNS, INC.

PoE = G2 ATX Power-over-Ethernet (PoE) ports 1...8 and G2 Expansion Module ports 1...12 A.n = G2 ATX Amplifier 1...4 EA.n = G2 External Amplifier 1...n CH.n = G2 Message Remote 2 Channel 1 or 2 2/15/2024 - 1:27PM

SYMBOL DESCRIPTION
G2 I/O REMOTE
PUSH BUTTON - RED G2 STROBE LIGHT

SPEAKER, WEATHER-PROOF SPEAKER, FLUSH MOUNT SPEAKER, METAL BOX G2 LED SPEAKER, FLUSH MOUNT G2 LED SPEAKER, METAL BOX OEM TRANSFORMER G2 HDTV REMOTE G2 COLOR

INDICATOR REMOTE
OEM FLAT PANEL MONITOR, XX", WITH MOUNT G2 MESSAGE SIGN (STANDARD 24") VOLUME CONTROL
(CUSTOMER SUPPLIED)
G2 ROOM REMOTE 2

ARTICULATING ARM

MOUNT - LONG

ADAPTER PLATE DOUBLE
PUSH BUTTON - BLACK G2 OMNIALERT STROBE SPEAKER
G2 MESSAGE SIGN
(MINI 12") G2 MESSAGE SIGN
(EXTENDED 36") ADAPTER PLATE
SINGLE
G2 MESSAGE REMOTE 2
G2 ATX
STATION CONTROLLER G2 EXPANSION MODULE G2-UNINTERRUPTIBLE

POWER SUPPLY OEM AMPLIFIER

SYMBOL DESCRIPTION
TVR
PB

BLACK PB

RED CIR
STR
ATX
I/O
T
UPS
AMP
MR2
EXP
RR2
S
S
S

ADS MSE
MSML
MSS
MSM
VC
S
S
ADP
MSML
S
LAR
G2 LOCAL AREA REMOTE
FPD MOUNT FPM - XX" address

END-USER APPROVES STATION
DESIGN FOR PURPOSES OF OBTAINING QUOTE.

INSTALLER CONFIRMS DESIGN
ALIGNS WITH SITE CONDITIONS. (SPEAKER MOUNTING TYPE, ATX LOCATION ETC.)

SIGNATURE REQUIRED
G2 VIDEO DOOR

STATION
VDS UNION CITY FD, CA (ALAMEDA COUNTY) FIRE STATION 31 33555 CENTRAL AVE, UNION CITY, CA DMG NOTES:

1. SEE ARCHITECTURAL SPECIFICATIONS FOR ALL ROUGH-IN AND INSTALLATION DETAILS.

2. US DIGITAL DESIGNS DOES NOT SUPPLY BACK BOXES, CONDUITS, OR MOUNTING FASTENERS.

3. PHOENIX G2 SYSTEM IS ABLE TO SIGNAL OWNER-FURBISHED SYSTEMS, (EXHAUST, LIGHT, GAS SHUT OFF, ETC.) BUT USDD DOES NOT SUPPLY THESE SYSTEMS AND CANNOT WARRANT OR SUPPORT ANY OF THEIR PERFORMANCE BEYOND THE TRANSMISSION OF RELAY SIGNAL TO THEM.

4. US DIGITAL DESIGNS FIRE STATION ALERTING PLANS ARE DIAGRAMMATIC AND FOR QUOTING PURPOSES ONLY. DRAWING MAY NOT BE TO SCALE.

INSTALLER NOTES:

1. INSTALLER TO VERIFY WALL AND CEILING TYPE TO DETERMINE NEED FOR FLUSH OR SURFACE MOUNT INSTALLATION OF EQUIPMENT SPECIFIED.

2. INSTALLER TO COORDINATE CONNECTION BETWEEN ATX STATION CONTROLLER’S LINE-LEVEL AUDIO OUTPUT AND (EXISTING) OWNER-FURBISHED HOUSE AUDIO SYSTEM (AMP). (IF APPLICABLE)

3. INSTALLER TO PROVIDE CAT6 & 18/4 CABLES FROM ATX CONTROLLER TO CUSTOMER'S STATION RADIO FOR BACKUP.

4. INSTALLER TO PROVIDE CAT6 CABLE FROM ATX CONTROLLER WAN OUTPUT TO CUSTOMER'S IN-STATION NETWORK.

5. INSTALLER TO COORDINATE CONNECTION BETWEEN EXISTING STATION LIGHTING CONTROL SYSTEM AND RELAY OUTPUT FROM ATX STATION CONTROLLER OR I/O REMOTE WITH OWNER. (IF APPLICABLE)

6. VOLUME CONTROL TO BE PROVIDED BY OWNER OR INSTALLER IF SHOWN ON DRAWING.

7. INSTALLER TO VERIFY AND CONSIDER LOCATION(S) OF NETWORK AND RADIO CONNECTIONS.

S
S
S
S
S S
S
S S
S
A.1RR2 PoE S

T TVR CIR
PoE

TO ATX SWITCH ONLY VDS
MR2
S
PB

RED ADP MSML MSS MSS
ATX
UPS
S
EMERGENCY ALERT PoE
TO MR2 BY ATX
PB
RED EMERGENCY ALERT PoE
A.2 S
S
Count Name
1 G2 ATX STATION CONTROLLER
1 G2 COLOR INDICATOR REMOTE
1 G2 HDTV REMOTE
13 G2 LED SPEAKER (G2-LVL-HC-70)
1 G2 MESSAGE REMOTE 2
2 G2 MESSAGE SIGN STANDARD (MS-G2-S)
1 G2 MS ADAPTOR PLATE DOUBLE (AP-D)
1 G2 OMNISTROBE SPEAKER
1 G2 UPS (G2-UPS)
1 MS-MNT-ART-L
2 PUSH BUTTON (RED)
1 ROOM REMOTE 2 (RR-2)
1 SPEAKER WEATHER-PROOF
1 TRANSFORMER
1 VIDEO DOOR STATION
Count Name
4 G2 PoE PORT REQUIRED
USDD.CA_UNCTY.FS32.FSA.DWG design by

A B C D
4 3
2 1
4 2
1 A B C D
3 project building filename date

T H I S D O C U M E N T CONTAINS CONFIDENTIAL A N D P R O P R I E T A R Y

INFORMATION WHICH IS

THE EXCLUSIVE PROPERTY OF US DIGITAL DESIGNS,
I N C . R EP R O D U C T I O N , DISTRIBUTION OR USE BY OTHERS, IN WHOLE OR IN

PART, IS NOT PERMITTED WITHOUT THE WRITTEN
AUTHORIZATION FROM US DIGITAL DESIGNS, INC.

PoE = G2 ATX Power-over-Ethernet (PoE) ports 1...8 and G2 Expansion Module ports 1...12 A.n = G2 ATX Amplifier 1...4 EA.n = G2 External Amplifier 1...n CH.n = G2 Message Remote 2 Channel 1 or 2 2/15/2024 - 1:59PM

SYMBOL DESCRIPTION
G2 I/O REMOTE
PUSH BUTTON - RED G2 STROBE LIGHT

SPEAKER, WEATHER-PROOF SPEAKER, FLUSH MOUNT SPEAKER, METAL BOX G2 LED SPEAKER, FLUSH MOUNT G2 LED SPEAKER, METAL BOX OEM TRANSFORMER G2 HDTV REMOTE G2 COLOR

INDICATOR REMOTE
OEM FLAT PANEL MONITOR, XX", WITH MOUNT G2 MESSAGE SIGN (STANDARD 24") VOLUME CONTROL
(CUSTOMER SUPPLIED)
G2 ROOM REMOTE 2

ARTICULATING ARM

MOUNT - LONG

ADAPTER PLATE DOUBLE
PUSH BUTTON - BLACK G2 OMNIALERT STROBE SPEAKER
G2 MESSAGE SIGN
(MINI 12") G2 MESSAGE SIGN
(EXTENDED 36") ADAPTER PLATE
SINGLE
G2 MESSAGE REMOTE 2
G2 ATX
STATION CONTROLLER G2 EXPANSION MODULE G2-UNINTERRUPTIBLE

POWER SUPPLY OEM AMPLIFIER

SYMBOL DESCRIPTION
TVR
PB

BLACK PB

RED CIR
STR
ATX
I/O
T
UPS
AMP
MR2
EXP
RR2
S
S
S

ADS MSE
MSML
MSS
MSM
VC
S
S
ADP
MSML
S
LAR
G2 LOCAL AREA REMOTE
FPD MOUNT FPM - XX" address

END-USER APPROVES STATION
DESIGN FOR PURPOSES OF OBTAINING QUOTE.

INSTALLER CONFIRMS DESIGN
ALIGNS WITH SITE CONDITIONS. (SPEAKER MOUNTING TYPE, ATX LOCATION ETC.)

SIGNATURE REQUIRED
G2 VIDEO DOOR

STATION
VDS UNION CITY FD, CA (ALAMEDA COUNTY) FIRE STATION 32 31600 ALVARADO BLVD, UNION CITY, CA DMG NOTES:

1. SEE ARCHITECTURAL SPECIFICATIONS FOR ALL ROUGH-IN AND INSTALLATION DETAILS.

2. US DIGITAL DESIGNS DOES NOT SUPPLY BACK BOXES, CONDUITS, OR MOUNTING FASTENERS.

3. PHOENIX G2 SYSTEM IS ABLE TO SIGNAL OWNER-FURBISHED SYSTEMS, (EXHAUST, LIGHT, GAS SHUT OFF, ETC.) BUT USDD DOES NOT SUPPLY THESE SYSTEMS AND CANNOT WARRANT OR SUPPORT ANY OF THEIR PERFORMANCE BEYOND THE TRANSMISSION OF RELAY SIGNAL TO THEM.

4. US DIGITAL DESIGNS FIRE STATION ALERTING PLANS ARE DIAGRAMMATIC AND FOR QUOTING PURPOSES ONLY. DRAWING MAY NOT BE TO SCALE.

INSTALLER NOTES:

1. INSTALLER TO VERIFY WALL AND CEILING TYPE TO DETERMINE NEED FOR FLUSH OR SURFACE MOUNT INSTALLATION OF EQUIPMENT SPECIFIED.

2. INSTALLER TO COORDINATE CONNECTION BETWEEN ATX STATION CONTROLLER’S LINE-LEVEL AUDIO OUTPUT AND (EXISTING) OWNER-FURBISHED HOUSE AUDIO SYSTEM (AMP). (IF APPLICABLE)

3. INSTALLER TO PROVIDE CAT6 & 18/4 CABLES FROM ATX CONTROLLER TO CUSTOMER'S STATION RADIO FOR BACKUP.

4. INSTALLER TO PROVIDE CAT6 CABLE FROM ATX CONTROLLER WAN OUTPUT TO CUSTOMER'S IN-STATION NETWORK.

5. INSTALLER TO COORDINATE CONNECTION BETWEEN EXISTING STATION LIGHTING CONTROL SYSTEM AND RELAY OUTPUT FROM ATX STATION CONTROLLER OR I/O REMOTE WITH OWNER. (IF APPLICABLE)

6. VOLUME CONTROL TO BE PROVIDED BY OWNER OR INSTALLER IF SHOWN ON DRAWING.

7. INSTALLER TO VERIFY AND CONSIDER LOCATION(S) OF NETWORK AND RADIO CONNECTIONS.

S
S
S
S
S S
S S
S

S S TVR

TO ATX SWITCH ONLY S
STR
A.1 A.3 TVR

TO ATX SWITCH ONLY
ADP

MSML MSS
MSS
MR2
S CIR
ATX
UPS
S
S
S
PoE
PoE
TO MR2 BY ATX
A.2 (TAP @ 8W)
A.2 (TAP @ 8W)
A.2 (TAP @ 4W)
VDS PB

RED EMERGENCY ALERT
PoE
Count Name
1 G2 ATX STATION CONTROLLER
1 G2 COLOR INDICATOR REMOTE
2 G2 HDTV REMOTE
12 G2 LED SPEAKER (G2-LVL-HC-70)
1 G2 MESSAGE REMOTE 2
2 G2 MESSAGE SIGN STANDARD (MS-G2-S)
1 G2 MS ADAPTOR PLATE DOUBLE (AP-D)
1 G2 OMNISTROBE SPEAKER
1 G2 STROBE LIGHT
1 G2 UPS (G2-UPS)
1 MS-MNT-ART-L
1 PUSH BUTTON (RED)
3 SPEAKER WEATHER-PROOF
1 VIDEO DOOR STATION
Count Name
3 G2 PoE PORT REQUIRED
USDD.CA_UNCTY.FS33.FSA.DWG design by

A B C D
4 3
2 1
4 2
1 A B C D
3 project building filename date

T H I S D O C U M E N T CONTAINS CONFIDENTIAL A N D P R O P R I E T A R Y

INFORMATION WHICH IS

THE EXCLUSIVE PROPERTY OF US DIGITAL DESIGNS,
I N C . R EP R O D U C T I O N , DISTRIBUTION OR USE BY OTHERS, IN WHOLE OR IN

PART, IS NOT PERMITTED WITHOUT THE WRITTEN
AUTHORIZATION FROM US DIGITAL DESIGNS, INC.

PoE = G2 ATX Power-over-Ethernet (PoE) ports 1...8 and G2 Expansion Module ports 1...12 A.n = G2 ATX Amplifier 1...4 EA.n = G2 External Amplifier 1...n CH.n = G2 Message Remote 2 Channel 1 or 2 2/15/2024 - 2:52PM

SYMBOL DESCRIPTION
G2 I/O REMOTE
PUSH BUTTON - RED G2 STROBE LIGHT

SPEAKER, WEATHER-PROOF SPEAKER, FLUSH MOUNT SPEAKER, METAL BOX G2 LED SPEAKER, FLUSH MOUNT G2 LED SPEAKER, METAL BOX OEM TRANSFORMER G2 HDTV REMOTE G2 COLOR

INDICATOR REMOTE
OEM FLAT PANEL MONITOR, XX", WITH MOUNT G2 MESSAGE SIGN (STANDARD 24") VOLUME CONTROL
(CUSTOMER SUPPLIED)
G2 ROOM REMOTE 2

ARTICULATING ARM

MOUNT - LONG

ADAPTER PLATE DOUBLE
PUSH BUTTON - BLACK G2 OMNIALERT STROBE SPEAKER
G2 MESSAGE SIGN
(MINI 12") G2 MESSAGE SIGN
(EXTENDED 36") ADAPTER PLATE
SINGLE
G2 MESSAGE REMOTE 2
G2 ATX
STATION CONTROLLER G2 EXPANSION MODULE G2-UNINTERRUPTIBLE

POWER SUPPLY OEM AMPLIFIER

SYMBOL DESCRIPTION
TVR
PB

BLACK PB

RED CIR
STR
ATX
I/O
T
UPS
AMP
MR2
EXP
RR2
S
S
S

ADS MSE
MSML
MSS
MSM
VC
S
S
ADP
MSML
S
LAR
G2 LOCAL AREA REMOTE
FPD MOUNT FPM - XX" address

END-USER APPROVES STATION
DESIGN FOR PURPOSES OF OBTAINING QUOTE.

INSTALLER CONFIRMS DESIGN
ALIGNS WITH SITE CONDITIONS. (SPEAKER MOUNTING TYPE, ATX LOCATION ETC.)

SIGNATURE REQUIRED
G2 VIDEO DOOR

STATION
VDS UNION CITY FD, CA (ALAMEDA COUNTY) FIRE STATION 33 33942 7TH ST, UNION CITY, CA DMG NOTES:

1. SEE ARCHITECTURAL SPECIFICATIONS FOR ALL ROUGH-IN AND INSTALLATION DETAILS.

2. US DIGITAL DESIGNS DOES NOT SUPPLY BACK BOXES, CONDUITS, OR MOUNTING FASTENERS.

3. PHOENIX G2 SYSTEM IS ABLE TO SIGNAL OWNER-FURBISHED SYSTEMS, (EXHAUST, LIGHT, GAS SHUT OFF, ETC.) BUT USDD DOES NOT SUPPLY THESE SYSTEMS AND CANNOT WARRANT OR SUPPORT ANY OF THEIR PERFORMANCE BEYOND THE TRANSMISSION OF RELAY SIGNAL TO THEM.

4. US DIGITAL DESIGNS FIRE STATION ALERTING PLANS ARE DIAGRAMMATIC AND FOR QUOTING PURPOSES ONLY. DRAWING MAY NOT BE TO SCALE.

INSTALLER NOTES:

1. INSTALLER TO VERIFY WALL AND CEILING TYPE TO DETERMINE NEED FOR FLUSH OR SURFACE MOUNT INSTALLATION OF EQUIPMENT SPECIFIED.

2. INSTALLER TO COORDINATE CONNECTION BETWEEN ATX STATION CONTROLLER’S LINE-LEVEL AUDIO OUTPUT AND (EXISTING) OWNER-FURBISHED HOUSE AUDIO SYSTEM (AMP). (IF APPLICABLE)

3. INSTALLER TO PROVIDE CAT6 & 18/4 CABLES FROM ATX CONTROLLER TO CUSTOMER'S STATION RADIO FOR BACKUP.

4. INSTALLER TO PROVIDE CAT6 CABLE FROM ATX CONTROLLER WAN OUTPUT TO CUSTOMER'S IN-STATION NETWORK.

5. INSTALLER TO COORDINATE CONNECTION BETWEEN EXISTING STATION LIGHTING CONTROL SYSTEM AND RELAY OUTPUT FROM ATX STATION CONTROLLER OR I/O REMOTE WITH OWNER. (IF APPLICABLE)

6. VOLUME CONTROL TO BE PROVIDED BY OWNER OR INSTALLER IF SHOWN ON DRAWING.

7. INSTALLER TO VERIFY AND CONSIDER LOCATION(S) OF NETWORK AND RADIO CONNECTIONS.

VDS
ADP

MSML MSS MSS
MR2
S TVR
PB

RED CIR

ATX UPS
S

EMERGENCY ALERT

TO ATX SWITCH ONLY
PoE
PoE
TO MR2-A BY ATX
TVR
TO ATX SWITCH ONLY RR2 PoE
PB
RED EMERGENCY ALERT A.1

S S S S
S
S
S
S
S
S
S
S
S
S
S
S S
S
S
S
S
S
STR
A.3
A.2 S
S
A.4 MR2-B CH.1 MR2-B CH.2 MR2-C CH.1 MR2-C CH.2
MR2-D CH.1 S
S
MR2-A PoE MR2
CH.1CH.2 MR2-B PoE MR2
CH.1CH.2 MR2-C PoE MR2
CH.1 MR2-D PoE
Count Name
1 G2 ATX STATION CONTROLLER
1 G2 COLOR INDICATOR REMOTE
2 G2 HDTV REMOTE
26 G2 LED SPEAKER (G2-LVL-HC-70)
4 G2 MESSAGE REMOTE 2
2 G2 MESSAGE SIGN STANDARD (MS-G2-S)
1 G2 MS ADAPTOR PLATE DOUBLE (AP-D)
1 G2 OMNISTROBE SPEAKER
1 G2 STROBE LIGHT
1 G2 UPS (G2-UPS)
1 MS-MNT-ART-L
2 PUSH BUTTON (RED)
1 ROOM REMOTE 2 (RR-2)
1 SPEAKER WEATHER-PROOF
1 VIDEO DOOR STATION
Count Name
7 G2 PoE PORT REQUIRED

← All documents from this meeting