PREPARED ESPECIALLY FOR:
CITY OF VISALIA
FIRE DEPARTMENT
Two (2) Pierce Manufacturing, Inc.
Enforcer 1500 GPM Pumpers
Product Proposal
Standard Terms and Conditions (Exhibit A)
Product Specifications (Exhibit B)
▪ Supporting Documents (If Applicable)
◦ Electrical Analysis
◦ Turning Radius Report
Product Warranties (Exhibit C)
Dealer Supplied Products and/or Services (Exhibit D)
TABLE OF CONTENTS
1 2
3 4
5 goldenstatefire.com
JROGHQVWDWHĆUHFRP
PRODUCT
PROPOSAL1
goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
PRODUCT PROPOSAL FOR:
City of Visalia Fire Department
420 N. Burke Street
Visalia, CA 93292
Sales Consultant
Dewayne Young
[email protected]
Mobile: (209) 777-0650
Golden State Fire Apparatus, Inc. (“GSFA ”) is pleased to provide this proposal for the fire apparatus(es) and equipment identified below (the " Product”) to CITY OF VISALIA FIRE DEPARTMENT (“Customer ”) for consideration. This proposal (this “Product Proposal ”) includes the following exhibits attached hereto: the Standard Terms and Conditions attached as Exhibit A (the “Terms and Conditions ”); the Product Specifications attached as Exhibit B (the “Specifications ”); the Product Warranties attached as Exhibit C ; and the Dealer Supplied Products and/or Services attached as Exhibit D (the “Dealer Supplied Products/Services List”) (all of the foregoing, collectively, the “ Agreement”). Through its signature below or other Acceptance (as defined on page 2), Customer acknowledges having received and read, and agrees to be bound by, the Agreement. The Agreement shall be effective as of the latest date appearing in the signature blocks below (the “ Executed Date”).
PAYMENT TERMS – Customer shall pay the total purchase price set forth directly above (the “Grand Total Purchase Price”) to GSFA within thirty (30) calendar days of the Executed Date. If payment of the Grand Total Purchase Price is late, a late fee as sp ecified in section 6 of the Terms and Conditions may be applied, and the Prepayment Discount may be adjusted, and the Grand Total P urchase Price increased in accordance with section 2.c of the Terms and Conditions. Customer shall pay any balance due as a result of Change Orders to GSFA at the time of GSFA’s delivery of the applicable Product to Customer’s address listed above (or Cust omer’s pick up of such Product at GSFA’s facilities, as applicable and if approved by GSFA) .
MANUFACTURER – Customer acknowledges that GSFA is not an agent of the Product manufacturer identified above (“Manufacturer”) and is not capable of binding Manufacturer. Within five (5) business days of the Executed Date, GSFA shall submit an order form to the Manufacturer for the Product. GSFA’s further performance under the Agreement is contingent upon Manufacturer’s acceptance of such order form at the price and on the terms GSFA believed to be available when submitting this Product Proposal to Customer. If Manufacturer rejects such order as submitted or fails to respond to GSFA within a reasonable SUBMITTED DATE EXPIRATION DATE GSFA PROPOSAL # MANUFACTURER BID # MANUFACTURER CONSORTIUM 08/04/2023 08/31/2023 30804-23A 931 Pierce
Manufacturing Inc.
Sourcewell #113021,
ID #259 – Member
#84881
ITEM PRODUCT DESCRIPTION UNIT PRICE
A Two (2) Pierce Manufacturing Inc. Enforcer 1500 GPM Pumpers 2,073,677.36 B Pre-Payment Discount for 100% Payment at Time of Order (the “Prepayment Discount”) (323,379.08) C SUBTOTAL 1,750,298.28
D 8.50% State Sales Tax 148,775.36
E California Tire Fee 21.00
F 100% Performance Bond 4,056.00
G GRAND TOTAL PURCHASE PRICE 1,903,150.64
goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
amount of time, GSFA shall notify Customer in writing, and unless GSFA and Customer otherwise agree in writing, the Agreement shall then terminate and have no further force or effect.
PRODUCT COMPLETION – The Product shall be ready for final inspection by Customer at the manufacturing facility within approximately 43.5 to 46.5 MONTHS after the Executed Date. The foregoing estimate is provided as a good faith approximation as of the date of submission of this Product Proposal and is subject to the Terms and Conditions.
PREDELIVERY SERVICE – If applicable, after transportation from the manufacturing facility and prior to final delivery or pick up, the Product shall receive those additional Products and/or services identified on the Dealer Supplied Products/Services List. It is estimated that such a service will add approximately 0.5 to 1 MONTH(S) to the above Product completion estimate. The foregoing estimate is provided as a good faith approximation as of the date of submission of this Product Proposal and is subject to the Terms and Conditions.
PROPOSAL EXPIRATION – This Product Proposal supersedes any previous proposal(s) presented to Customer by GSFA and its employees and may be accepted by Customer on or before the Expiration Date identified above. Unless accepted by the Expiratio n Date, GSFA reserves the right to withdraw this Product Proposal or to alter its terms (including by providing updated Product pricing) prior to an order being accepted.
PURCHASE ORDER – If the Customer elects to issue a Purchase Order (PO) it shall be made out to: Golden State Fire Apparatus, Inc. – 7400 Reese Road – Sacramento, CA 95828.
ACCEPTANCE – ACCEPTANCE OF THIS PROPOSAL CREATES AN ENFORCEABLE BINDING AGREEMENT BETWEEN GSFA AND CUSTOMER. “ACCEPTANCE” MEANS THAT THE CUSTOMER DELIVERS TO GSFA: (A) A SIGNED COPY OF THIS PRODUCT PROPOSAL, OR (B) A SIGNED COPY OF A PURCHASE ORDER INCORPORATING THE AGREEMENT IN ITS ENTIRETY. ANY ADDITIONAL OR DIFFERENT TERMS, WHETHER CONTAINED IN CUSTOMER’S FORMS OR OTHERWISE PRESENTED BY CUSTOMER AT ANY TIME, ARE HEREBY REJECTED AND OF NO EFFECT UNLESS APPROVED IN WRITING SIGNED BY GSFA.
COUNTERPARTS - This Product Proposal may be executed in multiple counterparts, each of which shall be deemed an original (including copies sent to a party by electronic transmission) as against the party signing such counterpart, but which together shall constitute one and the same instrument. A signed copy of this Product Proposal delivered by facsimile, email or other means of electronic transmission will be deemed to have the same legal effect as delivery of an original signed copy of this Product P roposal.
If this Product Proposal is returned to GSFA with the signature of Customer’s authorized representative but without an attestation or co-signers signature, then absent Customer’s written notice to the contrary, GSFA shall be entitled to rely on such single signa ture as sufficient evidence of the signatory’s authority to execute the Agreement and bind Customer thereby.
[Signature Page Follows]
goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
INTENDING TO CREATE A BINDING AGREEMENT, Customer and GSFA have each caused this Product Proposal to be executed by their duly authorized representatives effective as of the Executed Date.
ACCEPTED AND AGREED TO BY CUSTOMER
AUTHORIZED CUSTOMER REPRESENTATIVE:
_______________________________________
Signature
_______________________________________
Print Name
_______________________________________
Title
_______________________________________
Date
ACCEPTED AND AGREED TO BY GSFA
AUTHORIZED GSFA REPRESENTATIVE:
_______________________________________
Signature
_______________________________________
Print Name
_______________________________________
Title
_______________________________________
Date
JROGHQVWDWHĆUHFRP
STANDARD TERMS
AND CONDITIONS
Exhibit “A”
2 1
STANDARD TERMS AND CONDITIONS
1. Definitions.
a. “Agreement” has the meaning given in the Product Proposal. b. “Customer” means the customer identified in the Product Proposal. c. “Dealer Preparation ,” if applicable, means additional product(s) and/or services added by GSFA after Manufacturer’s completion of the Product and prior to d elivery, in accordance with the Dealer Supplied Products/Services List.
d. “Dealer Supplied Products/Services List” means the Dealer Supplied Products and/or Services List attached to the Product Proposal as Exhibit D, which reflects all Dealer Pre paration under the Agreement absent a valid Change Order(s).
e. “Grand Total Purchase Price ” means the total purchase price for the Product identified in the Product Proposal (subject to any adjustments required or permitted by these Terms and Conditions, including by the execution of a valid Change Order(s).
f. “GSFA” means Golden State Fire Apparatus, Inc., a California corporation. g. “Manufacturer” means the person or persons, company, firm, corporation, partnership, or other organization identified in the Product Proposal as responsible for manufacturing the Product . h. “Party” or “Parties” means GSFA and/or Customer, as applicable. i. “Prepayment Discount” means a discount to the purchase price for the Product granted to Customer in connection with Customer’s advance payment of the Grand Total Purchase Price (or portion thereof, as specified in the Product Proposal).
j. “Product” means the fire apparatus(es) and any associated equipment listed in the Product Proposal and further described in the Specifications.
k. “Product Proposal” means the GSFA proposal executed by Customer to which these Terms and Conditions are attached.
l. “Product Warranties ” means the Manufacturer warranties for the Product attached to the Product Proposal as Exhibit C.
m. “Specifications” means the specifications for the Product attached to the Product Proposal as Exhibit B. n. “Terms and Conditions ” means these Standard Terms and Conditions , which are attached to the Product Proposal as Exhibit A.
2. Purchase and Payment.
a. Purchase. Customer agrees to purchase the Product a t the Grand Total Purchase Price (as such amount may be adjusted in accordance with these Terms and Conditions) , pursuant to the payment terms set forth in the Product Proposal. The Grand Total Purchase Price is payable in U.S. dollars.
b. Contingency Reserve Fund. The Grand Total Purchase Price may include an amount to be set aside for the purpose of funding any future costs or financial obligations incurred by Customer under the Product Proposal or any valid Change Order(s) (the “Contingency Reserve Fund”). If applicable, the amount of any required Contingency Reserve Fund will be set forth in either the Product Proposal or Exhibit D. The Contingency Reserve Fund may be withdrawn against by Customer or GSFA for the purpose of satisfying Customer’s payment obligations under the initial Product Proposal or any valid Change Order (s) (including, without limitation, a Change Order submitted by GSFA pursuant to Section 8.b). If a Contingency Reserve Fund is required under the Agreement, the amount of such fund is not intended as an estimate of the actual additional costs of contingencies, Change Orders, unforeseen items or other required work that may be incurred under the Agreement after submissi on of the Product Proposal to Customer, which amounts Customer acknowledges may exceed the Contingency Reserve Fund amount. The balance of any Contingency Reserve Fund will be credited against Customer’s payment obligations, or otherwise returned to Customer within thirty (30) calendar days of delivery of all Products under the Agreement (provided that Customer has paid all amounts owed under the Agreement as of such date).
2 c. Prepayment Discount . If GSFA has granted Customer a Prepayment Discount, Customer must provide each associated prepayment (each, a “ Prepayment”) within the time frame specified in the Product Proposal in order to receive such discount. Customer’s failure to timely make such Prepayment may result in: (i) GSFA’s termination of the Agreement; and/or (ii) Customer’s loss of the Prepayment Discount for the portion of the Grand Total Purchase Price represented by such outstanding Prepayment and the application of a late f ee as set forth in Section 6, in each case in GSFA’s sole discretion.
d. State Sales Tax. Customer shall be responsible for the cost of state sales tax associated with, or attributable to, the Product. The taxes stated in the Product Proposal are subject to adjustment for the applicable state sales tax rate in effect at the time of delivery. Therefore, the sales tax set forth on the Product Proposal is only an estimate of such taxes and will be increased or decreased at the time of d elivery if a c hange in the applicable sales tax rate has occurred, in which case Customer shall pay GSFA (or be refunded by GSFA) the difference in the applicable sales tax.
3. Product Completion Date . Within thirty (30) calendar days of the date on which the last required signatory executes the Product Proposal (such date, the “Executed Date”), GSFA shall submit to Customer a tentative Product completion date (which may differ from the Product completion estimate contained in the Product Proposal) . Due to global s upply chain constraints, any P roduct completion date contained herein, or in the Product Proposal , or otherwise provided to Customer , is a good faith estimate only as of the date provided to Customer, and merely an approximation based on current information available to GSFA and Manufacturer. Customer shall not be entitled to rely on any such estimate, and GSFA shall have no liability to Customer for a failure by GSFA or Manufacturer to meet any such estimate. All Product completion estimates are subject to modification and, if applicable, GSFA will provide updates to such estimates to Customer when available.
4. Stock / Demo Units. Notwithstanding any other provision contained in the Agreement (including Section 12 hereof concerning warranties), any Products constituting stock/demo unit(s) are sold to Customer on an as -is, first-come and first served-basis and GSFA makes no further representation or warranty to any customer with respect to such unit(s). Regardless of the terms of the Product Proposal, GSFA shall only be obligated to sell such stock/demo unit(s) to the first customer to enter into a purchase agreement with GSFA identifying such unit(s), and after the execution by GSFA of such agreement any subsequent purchase agreement (including the Agreement, as applicable) shall have no further force or effect with respect to such unit(s).
5. Multiple Unit Purchase. If the Grand Total Purchase Price includes pricing for multiple Products, the Product price stated in the Product Proposal shall only be valid if the quantity of Products being proposed are purchased at the same time, pursuant to the same Agreement. GSFA shall have no obligation to offer the same price for any Product if purchased by Customer pursuant to a later purchase agreement.
6. Late Fee; Storage Fee. A late fee equal to 0.033% of the outstanding portion of the Grand Total Purchase Price will be charged per calendar day for overdue payments beginning ten (1 0) calendar days after the payment is due and continuing for the first thirty (30) calendar days thereafter. After such thirty (30) calendar day period , the late fee shall increase to 0.044% per calendar day until payment of the outstanding portion of the Grand Total Purchase Price is received. If Customer is unable to satisfy the delivery requirements hereunder or is unwilling to take delivery of the Product, then GSFA shall be entitled to a storage charge running from the earlier of: (i) the date of d elivery agreed to between GSFA and Customer (provided GSFA is willing and able to deliver the Product on such date) , or (ii) twenty-one (21) calendar days after GSFA notifies Customer that the Product is available for delivery. The storage charge is equal to: (i) $175.00 per calendar day per apparatus stored, or (ii) the actual charges incurred by GSFA with a third party for storage of the Product, whichever is greater. Such storage charge shall continue until the actual time of delivery and Customer’s possession of the Product , and any such storage by GSFA or such third party shall be at the sole risk of Customer.
3 7. Delivery; Inspection and Acceptance.
a. Delivery. Subject to Section 5 hereof, the Product is scheduled to be delivered to the location and within the time period specified in the Product Proposal . Such delivery date is an estimate, and GSFA is , notwithstanding this Section 7.a, not bound to such date unless it otherwise agrees in a separate writing to complete delivery by a date certain. For the avoidance of doubt, GSFA is not responsible for delivery delays caused by or because of actions, omissions or conduct of Customer, the Manufacturer, or their respective employees, affiliates, suppliers, contractors, and carriers. Risk of loss for the Product shall pass to Customer at the point and time of delivery (which shall include an attempted delivery by GSFA which cannot be completed due to any act of Customer). However, title to the Product shall only pass to Customer upon d elivery if Customer has then fully paid GSFA all amounts due hereunder (including additional amounts due under any valid Change Order). Absent GSFA’s separate written agreement, which it may or may not provide in its sole and absolute discretion, delivery of the Product will not occur before Customer has fully paid all amounts due under the Agreement and provided proof of insurance reasonably satisfactory to GSFA . If GSFA permits Customer to take possession of the Product, Customer may not mount equipment, conduct training, or place the Product into service until all amounts due under the Agreement have been paid. If Cust omer has ordered multiple Products, GSFA reserves the right to deliver such Products in installments and to separately invoice Customer for such Products.
b. Inspection and Acceptance . Upon delivery, Customer shall have ten (10) calendar days within which to inspect the Product for substantial conformance to the Specifications, and in the event of substantial non- conformance to the Specifications to furnish GSFA with written notice sufficient to permit GSFA to evaluate such non-conformance (“ Notice of Nonconformance to Specifications ”). Contingent upon part availability and Customer’s cooperation, any Product not in substantial conformance to material Specifications shall be remedied by GSFA (by repair or replacement, at GSFA’s election) within thirty (30) calendar days from GSFA’s receipt of the Notice of Nonconformance to Specifications. In the event GSFA does not receive a Notice of Nonconformance to Specifications within ten (10) calendar days of d elivery, the Product will be d eemed to be in conformance with Specifications and accepted by Customer.
8. Changes to Agreement Terms.
a. Change Orders . The Customer may request that GSFA incorporate a change to the Product or the Specifications for the Product, or GSFA may submit changes to the Agreement required or permitted to be made by GSFA (pursuant to Section 8.b or otherwise) by delivering a written Change Order to the other party hereto , which shall include a description of the proposed change sufficient to permit the receiving party to evaluate the feasibility of such change ( either, a “Change Order”). For any Change Order submitted by Customer, GSFA will provide Customer a written response (a “Response”) stating (i) whether GSFA will accommodate such Change Order (which GSFA may decide in its sole and absolute discretion) ; and (ii) the terms of the modification to the order, including any increase or decrease in the Grand Total Purchase Price resulting from such Change Order, a date on which any increase in the Grand Total Purchase Price must be paid, and an estimate of any effect on production scheduling or delivery resulting from such Change Order. Customer shall have seven (7) calendar days after receipt of the Response to notify GSFA as to whether Customer desires to make the changes GSFA has approved in the Response. I n the event Customer countersigns GSFA’s Response, Customer shall pay the increase (or be refunded the decrease) in the Grand Total Purchase Price by the date specified in the Response. GSFA may also send Customer a Change Order to account for any changes to the Agreement required or permitted to be made by GSFA (including those changes required pursuant to Section 8.b hereof), and such Change Order shall be effective upon delivery to Customer unless Customer elects to terminate the applicable Product order under the Agreement in accordance with Section 9.
b. Additional Changes.
i. Component Price Volatility . GSFA shall not be responsible for any unforeseen price increase or surcharge enacted by suppliers of major components of the Product (including but not limited to commercial chassis, engine, transmission, and fire pump) after Customer becomes bound by the Agreement . Customer shall be responsible for all amounts arising from a ny price increas es for major components of the P roduct (including all 4 associated taxes and fees thereon) occurring after the execution of the Agreement which increases the cost of the Product to GSFA, and such amounts will be documented on a Change Order adjusting the Grand Total Purchase Price accordingly. Customer shall pay any such price increase prior to Product delivery.
ii. New Legal Standards. In the event the Product design, materials or specifications require an alteration arising from new regulations issued by any governmental entity or trade association, including, but not limited to, the NFPA, DOT, and EPA , and such alteration increases the cost of the Product to GSFA , Customer shall be responsible for changes to the Grand Total Purchase Price arising from such alteration. GSFA shall promptly notify Customer when it becomes aware of any potential or required change in regulations occurring prior to delivery that would impact the Product purchased.
iii. Change Orders. Customer shall execute any Change Order submitted by GSFA documenting any of the changes required or permitted by Sections 8.b.i and 8.b.ii above (which shall, to the extent practicable, itemize any increases in the Grant Total Purchase Price and specify a commercially reasonable date by which Customer must pay such increase), unless Customer instead elects to terminate the applicable Product order under the Agreement within fifteen (15 ) calendar days of Customer’s receipt of such Change Order and in accordance with Section 9.
Absent such a termination , failure to execute a Change Order does not alter Customer’s obligations under this Section 8.b.
c. Changes in Commercial Specifications . Specifications for all components of the Product manufactured by companies other than the Manufacturer are subject to change without notice. Specifications for such components will be as available at the time of manufacture of the Product. GSFA shall not be liable for any deviations in such specifications arising from a substitution of components or changes in the design of any component by their original manufacturer.
9. Termination.
a. By Customer. Customer may terminate a Product order identified in the Product Proposal or a Change Order by providing written notice to GSFA in accordance with Section 16 hereof. If Customer elects to terminate a Product order, Customer shall pay GSFA a cancellation fee as follows: (a) after the Product order is accepted and entered by GSFA , 10% of the porti on of the Grand Total Purchase Price applicable to such Product (including all associated taxes, fees and costs) (such amount, the “ Product Purchase Price ”); (b) after completion of the pre- construction phase of the order process , 20% of the Product Purcha se Price; and (c) after the requisition of any materials or commencement of any manufacturing or assembly of the Product by either GSFA or Manufacturer but before substantial completion of such Product, 50% of the Product Purchase Price. Customer shall not be permitted to terminate a Product order after substantial completion of manufacturing and assembly of such Product (excluding any Dealer Preparation or other pre -delivery services or untypical Product customization, if applicable).
Notwithstanding the foregoing, if the applicable tier of cancellation fee is not sufficient to cover all actual costs and fees incurred by GSFA with Manufacturer in connection with Customer’s termination of the Product order (“Manufacturer Termination Fees”), then in addition to such cancellation fee Customer shall pay the balance of all Manufacturer Termination Fees. If Customer received a Prepayment Discount, such discount shall not be considered for the purpose of calculating the above cancellation fee. The tier of cancellation fee applicable to any cancellation , as well as the determination of whether a Product has reached substantial completion, shall be in the sole and absolute discretion of GSFA. Customer may request a fee waiver, and GSFA, in its sole discretion, may agree to waive and/or adjust such fee . GSFA will return the balance of the Grand Total Purchase Price or Product Purchas e Price, as applicable, within thirty (30) calendar days of the effective date of the cancellation of the Product ord er or termination of the Agreement.
Customer may terminate the Agreement for an Event of Default by GSFA after providing GSFA with written notice in accordance with Section 16 (which notice shall describe with reasonably particularity the Event of Default justifying such termination) if such Event of Default remains uncured (if capable of cure) thirty (30) days following GSFA’s receipt of such notice; provided, however, that the foregoing cure period shall continue if and for so long as GSFA 5 has commenced and is continuing to undertake commercially reasonable efforts to cure such Event of Default as promptly as reasonably practicable.
b. By GSFA . GSFA may terminate the Agreement for an Event of Default by Customer after providing Customer with written notice in accordance with Section 16 (which notice shall describe with reasonably particularity the Event of Default justifying such termination) if such Event of Default remains uncured (if capable of cure) thirty (30) days following Customer’s receipt of such notice; provided, however, that the foregoing cure period shall continue if and for so long as Customer has commenced and is continuing to undertake commercially reasonable efforts to cure such Event of Default as promptly as reasonably practicable. Notwithstanding the foregoing, GSFA may terminate the Agreement effective immediately upon written notice to Customer for Customer’s failure to pay any amount owed under the Agreement when due .
Notwithstanding any other provision of this Agreement, if Customer terminates a Product order in accordance with Section 9.a above, GSFA may elect to instead terminate the Agreement upon notice to Customer in accordance with Section 16 hereof. If GSFA terminates the Agreement in accordance with this Section 9 .b, Customer shall pay the applicable tier of cancellation fee for all Products pursuant to Section 9.a above as if Customer had elected to terminate each applicable Product order.
c. Based on Discontinuation or Cancellation by Manufacturer . In the event t hat Manufacturer cancels a Product order (provided that such cancellation is not the result of an act by Customer in violation of the Agreement) or discontinues the manufacture of a Product prior to its completion and d elivery: (i) if such Product is the only Product contemplated under the Agreement, then the Agreement shall terminate; or (ii) if additional Products are contemplated under the Agreement, then only the Product order for the applicable cancelled or disconti nued Product shall be terminated . Such Agreement termination or Product termination , as applicable, shall be effective upon GSFA’s written notice to Customer of such cancellation or discontinuance in accordance with Section 16 hereof.
GSFA’s only obligat ion to Customer in such event shall be the return of any Prepayment paid by Customer for the cancelled or discontinued Product. For the avoidance of doubt, the cancellation fees contemplated in Section 9.a hereof shall not apply in the event of a termination pursuant to this Section 9.c .
10. Customer’s Obligations . Customer shall provide its timely and best efforts to cooperate with GSFA and Manufacturer during the Product manufacturing process. Reasonable and timely cooperation includes, without limitation, Customer’s providing timely information in response to any requests from Manufacturer or GSFA and the participation of Customer’s authorized representatives in traveling to Manufacturer’s facility for inspections and approval of the Product, including a final approval before the Product leaves Manufacturer’s fac ility.
11. Representations and Warranties . Customer hereby represents and warrants to GSFA as of the Executed Date that the execution of the Agreement and the purchase of the Product(s) and performance of the other obligations of Customer under the Agreement have been approved by Customer in accordance with applicable general laws and, as applicable, Customer’s charter, ordinances , purchasing policies, and other governing documents, and executed by the appropriate Customer employees, officials, and/or representatives , and fundi ng for Customer’s performance of its obligations under the Agreement has been duly budgeted and appropriated by Customer.
12. Standard Warranty . All applicable M anufacturer warranties are contained in the Product Warranties . Any additional warranties must be expressly approved in a writing signed by GSFA, and Customer acknowledges and agrees that Manufacturer will not be liable for any such additional warranties .
a. Disclaimer. OTHER THAN AS EXPRESSLY SET FORTH IN THE AGREEMENT, GSFA, ITS AFFILIATES, AND THEIR
RESPECTIVE OFFICERS, DIRECTORS, EMPLOYEES, SHAREHOLDERS, AGENTS, OR REPRESENTATIVES, DO NOT MAKE
ANY EXPRESS OR IMPLIED WARRANTIES WITH RESPECT TO THE PRODUCT (WHETHER RELATING TO THE CONDITION
OR QUALITY OF THE PRODUCT, OR OTHERWISE) PROVIDED HEREUNDER OR OTHERWISE REGARDING THE
AGREEMENT (INCLUDING, WITHOUT LIMITATION, WITH RESPECT TO ANY APPLICABLE DEALER PREPARATION) , WHETHER ORAL OR WRITTEN, EXPRESS, IMPLIED OR STATUTORY. WITHOUT LIMITING THE FOREGOING, ANY
IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY, THE IMPLIED WARRANTY AGAINST INFRINGEMENT, THE 6 IMPLIED WARRANTY OR CONDITION OF FITNESS FOR A PARTICULAR PURPOSE , AND ANY IMPLIED WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE ARE EXPRESSLY EXCLUDED AND DISCLAIMED.
STATEMENTS MADE BY SALES CONSULTANTS OR IN PROMOTIONAL MATERIALS DO NOT CONSTITUTE WARRANTIES.
b. Exclusions of Incidental and Consequentia l Damages. In no event shall GSFA be liable for consequential, incidental, or punitive damages incurred by Customer in connection with any matter arising out of or relating to the Agreement, or the breach thereof, even if GSFA has been advised of the possibility of such damages, and regardless of whether such damages arise out of breach of warranty, the Agreement , indemnity, whether resulting from non- delivery or from GSFA’s own negligence, or otherwise, except and solely to the extent such damages arise from the gross negligence or willful misconduct of GSFA.
13. Default. The occurrence of one or more of the following events (each, an “Event of Default”) shall constitute a default under the Agreement: (a) Customer’s failure t o pay any amounts due or to perform any of its obligations under the Agreement; (b) GSFA’s failure to perform any of its obligations under the Agreement; (c) either Party becoming insolvent or becoming subject to bankruptcy or insolvency proceedings; (d) any representation made by either Party under the Agreement which is false in any material respect; (e) any action by Customer to dissolve, merge, consolidate or transfer a substantial porti on of its property to another entity during the term of the Agreement; (f) any other material breach of the terms of the Agreement by a Party; or (g ) a default or breach by Customer under any other agreement with GSFA or its affiliates.
14. Indemnification of GSFA . Customer shall indemnify, defend, and hold harmless GSFA, its agents, servants, successors and assigns from and against all losses, damages, injuries, claims, demands and expenses, including attorneys’ fees and other legal expenses, of whatever nature (“Damages”), to the extent Damages arise out of or in connection with: (i) Customer’s breach of the Agreement, or (ii) Customer’s use, storage, or operation of the Product following delivery, regardless of where, how, and by whom opera ted (excluding any negligent operation by GSFA ).
The indemnification and assumptions of liability and obligation herein provided shall continue in full force and effect notwithstanding the termination of the Agreement, whether by expiration of time, by operation of law or otherwise.
This provision is not intended to and shall not constitute the exclusive remedy of the P arties under the Agreement; the Parties may seek indemnity from one another under other legal principles, whether based in equity or law, so long as they do not nullify or cancel the effects of this paragraph.
15. Force Majeure. GSFA shall not be responsible nor deemed to be in default of any provision of the Agreement on account of delays in performance due to causes which are beyond GSFA’s or Manufacturer’s control and which make GSFA’s performance impracticable, including but not limited to wars, insurrections, strikes or labor unrest, riots, fires, storms, floods, other acts of nature, explosions, earthquakes, accidents, any act of federal, state or local government, failure or delays in transportation, inability to obtain necessary labor , supplies or manufacturing facilities, supply chain issues, allocation regulations or orders affecting materials, equipment, facilities or completed products, failure to obtain any required license or certificates, acts of God or the public enemy or terrorism, failure of transportation, disease, pandemics or epidemics, quarantine restrictions, failure of vendors (due to causes similar to those within the scope of this clause) to perform their agreements or labor troubles causing cessation, slowdown, or interruption of work.
16. Notice. Any notices, requests, consents, claims, demands, waivers and other communications required or permitted to be given hereunder must be given in writing at the address of each Party set forth below, or t o such other address as either P arty may substitute by written notice to the other in accordance with this Section 16 , by one of the following methods: hand delivery; registered, express, or certified mail, return receipt requested, postage prepaid; or nationally recognized private express courier. All such communications will be deemed to have been given: (i) when delivered by hand (with written confirmation of receipt); (ii) on the third (3 rd) calendar day after the
date mailed, by registered, express or certified mail; or (iii) when delivered by the addressee if sent by a nationally recognized private express courier.
7 GSFA: CUSTOMER:
Golden State Fire Apparatus Inc. To the address listed in the Product Proposal 7400 Reese Road
Sacramento, CA 95828
17. Contradictions. In the event of a conflict between the Agreement and any Change Order, or between Change Orders, the terms of the latest executed Change Order shall control.
18. Manufacturer’s Statement of Origin . It is agreed that the manufacturer’s statement of origin (“ MSO”) for the Product covered by the Agreement, if applicable, shall be retained and remain in the possession of GSFA per California Department of Vehicles (DMV) directive s. Notwithstanding the for egoing, GSFA shall provide Customer with the original MSO if the Customer is self- registering, and Customer shall comply with all good-faith Process of Duty and other DMV requirements applicable to the Product and retain its own MSO.
19. Assignment. The relationship of the Parties established under the Agreement is that of independent contractors and neither Party is a partner, employee, agent, or joint venturer of or with the other. Neither Party may assign its rights and obligations under the Agreement unless it has obtained the prior written approval of the other P arty.
20. Governing Law; Jurisdiction; Disputes. Without regard to any conflict of laws provisions, the Agreement is to be governed by and under the laws of the state of California. Prior to taking any legal action that may and/or can arise out of the Agreement, the Parties shall first attempt mediation with an agreed upon mediator. If the Parties cannot agree upon a mediator within thirty (30) calendar days of the submission of written notice of a dispute in accordance with Section 16 hereof, if any disputed matter remain unresolved within thirty (30) calendar days of the commencement of discussions, or if any party refuses to meet, then either party may submit any remaining disputes concerning and/or claim regarding the Agreement and/or the terms and conditions herein to the Superior Court, County of Sacramento (and the parties expressly consent to exclusive personal jurisdiction and venue before such court).
21. Entire Agreement; Amendments. The Agreement, including the Product Proposal, its exhibits and all valid Change Orders, is the exclusive agreement between the Parties regarding the subject matter contained herein and therein.
No change in, modi fication of, or revision of the Agreement shall be valid unless in writing and signed by duly authorized representatives of both Parties with authority to sign such amendments to the Agreement.
END OF STANDARD TERMS AND CONDITIONS
JROGHQVWDWHĆUHFRP
PRODUCT
SPECIFICATIONS
Exhibit “B”
3 Proposal Details Report
OptionCode
Type
Option
ProposalText
0766611
Boiler Plates, Pumper
Golden State Fire Apparatus Inc.
is pleased to submit a proposal to
Visalia Fire Department
for a
Pierce® triple combination pumper
per your request for quotation. The following paragraphs will describe in detail the apparatus, construction methods, and equipment proposed. This proposal will indicate size, type, model and make of components parts and equipment, providing proof of compliance with each and every item (except where noted) in the departments advertised specifications.
PIERCE MANUFACTURING was founded in
1913
. Since then we have been building bodies with
one philosophy, "BUILD THE FINEST". Our skilled craftsmen take pride in their work, which is reflected, in the final product. We have been building fire apparatus since the early "forties" giving Pierce Manufacturing over
75 years of experience in the fire apparatus market. Pierce Manufacturing has built and put into service more than
62,500
apparatus, including more than
33,900
on Pierce custom chassis designed and built specifically for fire and emergency applications. Our Appleton, Wisconsin facility has over 870,000
total square feet of floor space
situated on approximately
105
acres of land. Our Bradenton, Florida facility has
300,000
square
feet of floor space situated on approximately
38 acres of land.
Our beliefs in high ethical standards are carried through in all of our commitments and to everyone with whom we do business. Honesty, Integrity, Accountability and Citizenship are global tenets by which we all live and work. Consequently, we neither engage in, nor have we ever been convicted of price fixing, bid rigging, or collusion in any domestic or international fire apparatus market.
Pierce has only one brand of fire apparatus "Pierce", ensuring you are receiving top of the line product that meets your specification.
In accordance with the current edition of NFPA
1901
standards, this proposal will specify whether
the fire department, manufacturer, or apparatus dealership will provide required loose equipment.
Images and illustrative material in this proposal are as accurate as known at the time of publication, but are subject to change without notice. Images and illustrative material is for reference only, and may include optional equipment and accessories and may not include all standard equipment.
GENERAL DESIGN AND CONSTRUCTION
To control quality, ensure compatibility, and provide a single source for service and warranty, the custom cab, chassis, pump module and body will be entirely designed, assembled/welded and painted in Pierce owned manufacturing facilities. This includes, but not limited to the cab weldment, the pumphouse module assembly, the chassis assembly, the body and the electrical system.
QUALITY AND WORKMANSHIP
Pierce has set the pace for quality and workmanship in the fire apparatus field. Our tradition of building the highest quality units with craftsmen second to none has been the rule right from the beginning and we demonstrate that ongoing commitment by: Ensuring all steel welding follows American Welding Society D
1.1-2004
recommendations for structural steel welding. All aluminum welding follows American Welding society and ANSI D
1.2-2003
requirements for structural
welding of aluminum. All sheet metal welding follows American welding Society B
2.1-2000
requirements for structural welding of sheet metal. Our flux core arc welding uses alloy rods, type 7000
and is performed to American Welding Society standards A
5.20 -E
70 T
1 . Furthermore, all
employees classified as welders are tested and certified to meet the American welding Society codes upon hire and every three (
3 ) years thereafter. Pierce also employs and American Welding Society certified welding inspector in plant during working hours to monitor weld quality.
Pierce Manufacturing operates a Quality Management System under the requirements of ISO 9001
. These standards sponsored by the International Organization for Standardization (ISO) specify the quality systems that are established by the manufacturer for design, manufacture, installation and service. A copy of the certificate of compliance is included with this proposal.
In addition to the Quality Management system, we also employ a Quality Achievement Supplier program to insure the vendors and suppliers that we utilize meet the high standards we demand.
That is just part of our overall "Quality at the Source" program at Pierce.
To demonstrate the quality of our products and services, a list of at least two (
2 )
fire
departments/municipalities that have purchased vehicles for a second time is provided.
DELIVERY
The apparatus will be delivered under its own power to insure proper break-in of all components while the apparatus is still under warranty.
A qualified delivery representative shall deliver the
apparatus and remain for a sufficient length of time to instruct personnel in proper operation, care and maintenance of the equipment delivered.
MANUAL AND SERVICE INFORMATION
At time of delivery, complete operation and maintenance manuals covering the apparatus will be provided. A permanent plate will be mounted in the driver's compartment specifying the quantity and type of fluids required including engine oil, engine coolant, transmission, pump transmission lubrication, pump primer and drive axle.
SAFETY VIDEO
At the time of delivery Pierce will also provide one (
1 )
39 -minute, professionally produced
apparatus safety video, in DVD format. This video will address key safety considerations for personnel to follow when they are driving, operating, and maintaining the apparatus, including the following: vehicle pre-trip inspection, chassis operation, pump operation, aerial operation, and safety during maintenance.
PERFORMANCE TESTS
A road test will be conducted with the apparatus fully loaded and a continuous run of no less than ten (
10 ) miles. During that time the apparatus will show no loss of power nor will it overheat. The 8/4/2023
Customer:
VISALIA FIRE DEPARTMENT
Bid Number:
931
Representative
Young, Dewayne
Job Number:
Requirements Manager:
Organization:
Golden State Fire Apparatus, Inc
Description:
Visalia Fire, Enforcer Type 1 Pu
Chassis:
Enforcer Chassis
Body:
Pumper, Medium, Galvanneal, 2nd Gen
1 931
Bid #:
transmission drive shaft or shafts and the axles will run quietly and be free of abnormal vibration or noise. The apparatus when fully loaded will not have less than 25 percent nor more than
50 percent on the front axle, and not less than
50 percent nor more than
75 percent on the rear axle.
The apparatus will meet NFPA
1901
acceleration and braking requirements.
SERVICE AND WARRANTY SUPPORT
Pierce dealership support will be provided by
Golden State Emergency Vehicle Service
by
operating
a Pierce authorized service center. The service center will have factory-trained mechanics on staff versed in Pierce fire apparatus. The service facility will be located within two
hundred fifty (
250
) miles
of the fire department.
In addition to the dealership, Pierce has service facilities located in both, Weyauwega, Wisconsin and Bradenton, Florida. Pierce also maintains a dedicated parts facility of over 100,000
square
feet in Appleton, Wisconsin. The parts facility stocks in excess of $5,000,000
in parts dedicated to
service and replacement parts. The parts facility employs a staff dedicated solely for the distribution and shipment of service and replacement parts.
Service parts for the apparatus being proposed can be found via Pierceparts.com which, is an interactive online tool that delivers information regarding your specific apparatus as well as the opportunity to register for training classes.
As a Pierce customer you have the ability to view the complete bill of materials for your specific apparatus, including assembly drawings, piece part drawings, and beneficial parts notations. You will also have the ability to search the complete Pierce item master through a parts search function which offers all Pierce SKU's and descriptions offered on all Pierce apparatus. Published component catalogs, which include proprietary systems along with an extensive operators manual library is available for easy reference.
Pierce Manufacturing maintains a dedicated service and warranty staff of over 35 personnel,
dedicated to customer support, which also maintains a
24 hour
7 day a week toll free hot line,
four (
4 ) on staff EVTs, and offers hands-on repair and maintenance training classes multiple times a year.
LIABILITY
The successful bidder will defend any and all suits and assume all liability for the use of any patented process including any device or article forming a part of the apparatus or any appliance furnished under the contract.
INSURANCE PROVIDED BY BIDDER
COMMERCIAL GENERAL LIABILITY INSURANCE
The successful bidder will, during the performance of the contract and for three ( 3 )
years following acceptance of the product, keep in force at least the following minimum limits of commercial general liability insurance:
Each Occurrence
$1,000,000
Products/Completed Operations Aggregate
$1,000,000
Personal and Advertising Injury
$1,000,000
General Aggregate
$2,000,000
Coverage will be written on a Commercial General Liability form. The policy will be written on an occurrence form and will include Contractual Liability coverage for bodily injury and property damage subject to the terms and conditions of the policy.
The policy will include Owner as an additional insured when required by written contract.
COMMERCIAL AUTOMOBILE LIABILITY INSURANCE
The successful bidder will, during the performance of the contract, keep in force at least the following minimum limits of commercial automobile liability insurance and coverage will be written on a Commercial Automobile liability form:
Each Accident Combined Single Limit:
$1,000,000
UMBRELLA/EXCESS LIABILITY INSURANCE
The successful bidder will, during the performance of the contract and for three ( 3 )
years following acceptance of the product, keep in force at least the following minimum limits of umbrella liability insurance:
Aggregate:
$3,000,000
Each Occurrence:
$3,000,000
The umbrella policy will be written on an occurrence basis and at a minimum provide excess to the bidder's General Liability and Automobile Liability policies.
The required limits can be provided by one (
1 ) or more policies provided all other
insurance requirements are met.
Coverage will be provided by a carrier(s) rated A- or better by A.M. Best.
All policies will provide a
30 -day notice of cancellation to the named insured. The Certificate of Insurance will provide the following cancellation clause: Should any of the above described polices be cancelled before the expiration date thereof, notice will be delivered in accordance with the policy provisions.
Bidder agrees to furnish owner with a current Certificate of Insurance with the coverages listed above along with the bid. The certificate will show the purchaser as certificate holder.
INSURANCE PROVIDED BY MANUFACTURER
PRODUCT LIABILITY INSURANCE
The manufacturer will, during the performance of the contract and for three ( 3 ) years
following acceptance of the product, keep in force at least the following minimum limits of Product Liability insurance:
Each Occurrence
$1,000,000
Products/Completed Operations Aggregate
$1,000,000
Coverage will be written on a Commercial General Liability form. The policy will be written on an occurrence form. The manufacturer's policy will include the owner as additional insured when required by written contract between the Owner and a Pierce authorized dealer.
UMBRELLA/EXCESS LIABILITY INSURANCE
The manufacturer will, during the performance of the contract and for three ( 3 ) years
following acceptance of the product, keep in force at least the following minimum limits of umbrella liability insurance:
2 931
Bid #:
Each Occurrence:
$25,000,000
Aggregate:
$25,000,000
The umbrella policy will be written on an occurrence basis and provide excess to the manufacturer's General Liability/Products policies.
The required limits can be provided by one (
1 ) or more policies provided all other
insurance requirements are met.
Coverage will be provided by a carrier(s) rated A- or better by A.M. Best.
All policies will provide a
30 -day notice of cancellation to the named insured. The Certificate of Insurance will provide the following cancellation clause: Should any of the above described polices be cancelled before the expiration date thereof, notice will be delivered in accordance with the policy provisions.
Manufacturer agrees to furnish owner with a current Certificate of Insurance with the coverages listed above along with the bid. The certificate will show the purchaser as the certificate holder.
0661794
Single Source Compliance
SINGLE SOURCE MANUFACTURER
Pierce Manufacturing, Inc. provides an integrated approach to the design and manufacture of our products that delivers superior apparatus and a dedicated support team. From our facilities, the chassis, cab weldment, cab, pumphouse (including the sheet metal enclosure, valve controls, piping and operators panel) and body will be entirely designed, tested, and hand assembled to the customer's exact specifications. The electrical system either hardwired or multiplexed, will be both designed and integrated by Pierce Manufacturing. The warranties relative to these major components (excluding component warranties such as engine, transmission, axles, pump, etc.) will be provided by Pierce as a single source manufacturer. Pierce's single source solution adds value by providing a fully engineered product that offers durability, reliability, maintainability, performance, and a high level of quality.
0584456
Manufacture Location, Appleton,
Wisconsin
Your apparatus will be manufactured in Appleton, Wisconsin. 0584452
RFP Location: Appleton, Wisconsin
0588609
Vehicle Destination, US
0670275
Unit to be Similar in some Aspects,
Excluding Pump Panel
SPECIAL INSTRUCTIONS
The apparatus being proposed will be designed and built to match the Customers previous Job #
33716
. However, some variation may be necessary due to changes in our manufacturing processes or our product offering. Revisions in NFPA guidelines and/or other regulations may also affect our ability to match the previous unit.
0610784
Comply NFPA 1901 Changes
Effective Jan 1, 2016, With
Exceptions
NFPA
2016
STANDARDS
This unit will comply with the NFPA standards effective January 1 ,
2016
, except for fire
department directed exceptions. These exceptions will be set forth in the Statement of Exceptions.
Certification of slip resistance of all stepping, standing and walking surfaces will be supplied with delivery of the apparatus.
All horizontal surfaces designated as a standing or walking surface that are greater than
48.00 "
above the ground must be defined by a
1.00 " wide line along its outside perimeter. Perimeter markings and designated access paths to destination points will be identified on the customer approval print and are shown as approximate. Actual location(s) will be determined based on materials used and actual conditions at final build. Access paths may pass through hose storage areas and opening or removal of covers or restraints may be required. Access paths may require the operation of devices and equipment such as the aerial device or ladder rack.
A plate that is highly visible to the driver while seated will be provided. This plate will show the overall height, length, and gross vehicle weight rating.
The manufacturer will have programs in place for training, proficiency testing and performance for any staff involved with certifications.
An official of the company will designate, in writing, who is qualified to witness and certify test results.
0533347
Pumper/Pumper with Aerial Device
Fire Apparatus
0588611
Vehicle Certification, Pumper
3 931
Bid #:
0661778
Agency, Apparatus Certification,
Pumper/Tanker, U.L.
NFPA COMPLIANCY
Apparatus proposed by the bidder will meet the applicable requirements of the National Fire Protection Association (NFPA) as stated in current edition at time of contract execution. Fire department's specifications that differ from NFPA specifications will be indicated in the proposal as "non-NFPA".
PUMP TEST
Underwriters Laboratory (UL) will test, approved, and certify the pump. The test results and the pump manufacturer's certification of hydrostatic test; the engine manufacturer's certified brake horsepower curve; and the pump manufacturer's record of pump construction details will be forwarded to the Fire Department.
GENERATOR TEST
If the unit has a generator, Underwriters Laboratory (UL) will test, approved, and certify the generator. The test results will be provided to the Fire Department at the time of delivery.
BREATHING AIR TEST
If the unit has breathing air, Pierce Manufacturing will draw an air sample from the air system and have the sample certified that the air quality meets the requirements of NFPA 1989
,
Standard
on
Breathing Air Quality for Fire and Emergency Services Respiratory Protection. 0891947
Certification, Vehicle Inspection
Program, NFPA 1901
VEHICLE INSPECTION PROGRAM CERTIFICATION
To assure the vehicle is built to current NFPA
1901
standards, the apparatus, in its entirety, will
be third-party, independent, audit-certified through Underwriters Laboratory (UL) that it is built and complies to all applicable standards in the current edition. The certification includes: all design, production, operational, and performance testing of not only the apparatus, but those components that are installed on the apparatus.
A placard will be affixed in the driver's side area stating the third party agency, the date, the standard and the certificate number of the whole vehicle audit. 0766110
Consortium, Sourcewell
0537375
Unit of Measure, US Gallons
0030006
Bid Bond Not Requested
BID BOND NOT REQUESTED
A bid bond will not be included. If requested, the following will apply:
All bidders will provide a bid bond as security for the bid in the form of a 5%
bid bond to
accompany their bid. This bid bond will be issued by a Surety Company who is listed on the U.S.
Treasury Departments list of acceptable sureties as published in Department Circular 570
. The
bid bond will be issued by an authorized representative of the Surety Company and will be accompanied by a certified power of attorney dated on or before the date of bid. The bid bond will include language, which assures that the bidder/principal will give a bond or bonds as may be specified in the bidding or contract documents, with good and sufficient surety for the faithful performance of the contract, including the Basic One (
1 ) Year Limited Warranty, and for the
prompt payment of labor and material furnished in the prosecution of the contract.
Notwithstanding any document or assertion to the contrary, any surety bond related to the sale of a vehicle will apply only to the Basic One (
1 ) Year Limited Warranty for such vehicle. Any surety
bond related to the sale of a vehicle will not apply to any other warranties that are included within this bid (OEM or otherwise) or to the warranties (if any) of any third party of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. In the event of any contradiction or inconsistency between this provision and any other document or assertion, this provision will prevail.
0807707
Performance Bond, 100% with
Warranty Bond, 1 Yr, and Payment
Bond
PERFORMANCE BOND,
1 YEAR
The successful bidder will furnish a Performance and Payment bond (Bond) equal to 100
percent
of the total contract amount within
30 days of the notice of award. Such Bond will be in a form acceptable to the Owner and issued by a surety company included within the Department of Treasury's Listing of Approved Sureties (Department Circular 570
) with a minimum A.M. Best
Financial Strength Rating of A and Size Category of XV. In the event of a bond issued by a surety of a lesser Size Category, a minimum Financial Strength rating of A+ is required.
Bidder and Bidder's surety agree that the Bond issued hereunder, whether expressly stated or not, also includes the surety's guarantee of the vehicle manufacturer's Basic One ( 1 ) Year Limited
Warranty period included within this proposal. Owner agrees that the penal amount of this bond will be simultaneously amended to
100
percent of the total contract amount upon satisfactory
acceptance and delivery of the vehicle(s) included herein. Notwithstanding anything contained within this contract to the contrary, the surety's liability for any warranties of any type will not exceed one (
1 ) year from the date of such satisfactory acceptance and delivery, or the actual Basic One (
1 ) Year Limited Warranty period, whichever is shorter.
Due to global supply chain constraints, any delivery date contained herein is a good faith estimate as of the date of this order/contract, and merely an approximation based on current information. Delivery updates will be made available, and a final firm delivery date will be provided as soon as possible.
4 931
Bid #:
0000007
Approval Drawing
APPROVAL DRAWING
A drawing of the proposed apparatus will be prepared and provided to the purchaser for approval before construction begins. The Pierce sales representative will also be provided with a copy of the same drawing. The finalized and approved drawing will become part of the contract documents. This drawing will indicate the chassis make and model, location of the lights, siren, horns, compartments, major components, etc.
A "revised" approval drawing of the apparatus will be prepared and submitted by Pierce to the purchaser showing any changes made to the approval drawing. 0002928
Electrical Diagrams
ELECTRICAL WIRING DIAGRAMS
Two (
2 ) electrical wiring diagrams, prepared for the model of chassis and body, will be provided. 0649754
Enforcer Chassis
ENFORCER CHASSIS
The Pierce Enforcer
™
is the custom chassis developed exclusively for the fire service. Chassis provided will be a new, tilt-type custom fire apparatus. The chassis will be manufactured in the apparatus body builder's facility eliminating any split responsibility. The chassis will be designed and manufactured for heavy-duty service, with adequate strength, capacity for the intended load to be sustained, and the type of service required. The chassis will be the manufacturer's first line tilt cab.
0021007
Maximum Overall Height
MAXIMUM OVERALL HEIGHT
The maximum overall height of the apparatus will be
116.00
inches
.
0021010
Maximum Overall Length
MAXIMUM OVERALL LENGTH
The maximum overall length of the apparatus will be
363.50
"
.
0000110
Wheelbase
WHEELBASE
The wheelbase of the vehicle will be
192.5
inches
.
0000070
GVW Rating
GVW RATING
The gross vehicle weight rating will be
43,500
pounds
.
0729280
Frame Rails, 13.38 x 3.50 x .375,
Enforcer
FRAME
The chassis frame will be built with two (
2 ) steel channels bolted to five (
5 ) cross members or
more, depending on other options of the apparatus. The side rails will have a
13.38 " tall web over
the front and mid sections of the chassis, with a continuous smooth taper to
10.75 " over the rear
axle. Each rail will have a section modulus of
25.992
cubic inches and a resisting bending
moment (rbm) of
3,119,040
in-lb over the critical regions of the frame assembly, with a section modulus of
18.96 cubic inches with an rbm of
2,275,200
in-lb over the rear axle. The frame rails
will be constructed of
120,000
psi yield strength heat-treated
0.38 " thick steel with
3.50 " wide
flanges.
0889469
Frame Liner, "C/Inv L" 12.50" x 3.00"
x .25", AXT/Vel/Imp/Enf, 56" QVal
FRAME REINFORCEMENT
In addition, a mainframe internal liner will be provided. The liner will be an internal "C" design that steps to an internal "L" design over the rear axle. It will be heat-treated steel measuring
12.50 " x
3.00 " x
0.25 " through the front portion of the liner, stepping to
9.38 " x
3.00 " x
0.25 " through the
rear portion of the liner. Each liner will have a section modulus of
13.58 cubic inches, yield
strength of
110,000
psi, and rbm of
1,494,042
in-lb. Total rbm at wheelbase center will be
4,391,869
in-lb.
The frame liner will be mounted inside of the chassis frame rail and extend the full length of the frame.
5 931
Bid #:
0630705
Axle, Front, Oshkosh TAK-4, Non
Drive, 19,500 lb, Enforcer
FRONT NON DRIVE AXLE
The Oshkosh TAK-
4 ® front axle will be of the independent suspension design with a ground rating of
19,500
lb.
Upper and lower control arms will be used on each side of the axle. Upper control arm castings will be made of
100,000
-psi yield strength
8630
steel and the lower control arm casting will be
made of
55,000
-psi yield ductile iron.
The center cross members and side plates will be constructed out of 80,000
-psi yield strength
steel.
Each control arm will be mounted to the center section using elastomer bushings. These rubber bushings will rotate on low friction plain bearings and be lubricated for life. Each bushing will also have a flange end to absorb longitudinal impact loads, reducing noise and vibrations.
There will be nine (
9 ) grease fittings supplied, one (
1 ) on each control arm pivot and one (
1 ) on
the steering gear extension.
The upper control arm will be shorter than the lower arm so that wheel end geometry provides positive camber when deflected below rated load and negative camber above rated load.
Camber at load will be zero degrees for optimum tire life.
The ball joint bearing will be of low friction design and be maintenance free.
Toe links that are adjustable for alignment of the wheel to the center of the chassis will be provided.
The wheel ends must have little to no bump steer when the chassis encounters a hole or obstacle.
The steering linkage will provide proper steering angles for the inside and outside wheel, based on the vehicle wheelbase.
The axle will have a turning angle of up to
45 degrees.
0030264
Suspension, Front TAK-4, 19,500 lb,
Qtm/AXT/Imp/Vel/Enf/SFR
FRONT SUSPENSION
Front Oshkosh TAK-
4 ™
independent suspension will be provided with a minimum ground rating of
19,500
lb.
The independent suspension system will be designed to provide maximum ride comfort. The design will allow the vehicle to travel at highway speeds over improved road surfaces and at moderate speeds over rough terrain with minimal transfer of road shock and vibration to the vehicle's crew compartment.
Each wheel will have torsion bar type spring. In addition, each front wheel end will also have energy absorbing jounce bumpers to prevent bottoming of the suspension.
The suspension design will be such that there is at least
10.00 " of total wheel travel and a
minimum of
3.75 " before suspension bottoms.
The torsion bar anchor lock system allows for simple lean adjustments, without the use of shims.
One can adjust for a lean within
15 minutes per side. Anchor adjustment design is such that it allows for ride height adjustment on each side.
The independent suspension was put through a durability test that simulated 140,000
miles of
inner city driving.
0087572
Shock Absorbers, KONI, TAK-4,
Qtm/AXT/Imp/Vel/DCF/Enf
FRONT SHOCK ABSORBERS
KONI heavy-duty telescoping shock absorbers will be provided on the front suspension. 0000322
Oil Seals, Front Axle
FRONT OIL SEALS
Oil seals with viewing window will be provided on the front axle. 0899288
Tires, Front, Goodyear, Armor MAX
MSA, 425/65R22.50, 20 ply, Fire
Service Speed
FRONT TIRES
Front tires will be Goodyear
425/65
R
22.50 radials,
20 ply Armor MAX MSA, rated for
22,800
lb
maximum axle load and
75 mph maximum speed.
0019611
Wheels, Front, Alcoa, 22.50" x
12.25", Aluminum, Hub Pilot
The tires will be mounted on Alcoa 22.50" x 12.25" polished aluminum disc type wheels with a ten (10)stud, 11.25" bolt circle.
0530458
Axle, Rear, Meritor RS24-160, 24,000
lb, Saber/Enforcer
REAR AXLE
The rear axle will be a Meritor
™,
Model RS-
24-160
, with a capacity of
24,000
lb.
6 931
Bid #:
0814705
Top Speed of Vehicle, 68 MPH/109
KPH, Non-NFPA 2016
TOP SPEED OF VEHICLE
NFPA
1901
,
2016
edition requires limits on the top speed of vehicles. NFPA
4.15.2 requires that
the maximum top speed of fire apparatus with a GVWR over 26,000
lb will not exceed either
68 mph /
109
kph or the manufacturer's maximum fire service speed rating for the tires installed on the apparatus, whichever is lower. NFPA
4.15.3 requires that if the combined water tank and
foam agent tank on the fire apparatus exceed
1250
gallons or the GVWR of the vehicle is over
50,000
lb, the maximum top speed of the apparatus will not exceed either 60 mph /
96 kph or the
manufacturer's maximum fire service speed rating for the tires installed on the apparatus, whichever is lower. It is the intention of the standard to improve safety by limiting the speed of all apparatus to
68 mph /
109
kph , and tankers or heavy apparatus to
60 mph /
96 kph. By
requesting an exception to this requirement, the purchasing authority is consciously choosing to operate their apparatus at speeds above the limits designated as safe speeds by the NFPA Technical Committee on Fire Department Apparatus.
The top sped of the apparatus as manufactured exceeds the NFPA requirements. Per fire department specification of a top speed that exceeds NFPA requirements, the apparatus will be non-compliant to NFPA
1901
standards at time of contract execution.
The rear tires being specified have a top speed limit of 68 mph /
109
kph from the tire
manufacturer.
0565380
Suspen, Rear, Single Slipper Spring,
27,000 lb, Saber/Enforcer
REAR SUSPENSION
The rear suspension will be Standens, semi-elliptical,
3.00 " wide x
53.00 " long,
12 -leaf pack with
a ground rating of
27,000
lb. The spring hangers will be castings.
The two (
2 ) top leaves will wrap the forward spring hanger pin, and the rear of the spring will be a slipper style end that will ride in a rear slipper hanger. To reduce bending stress due to acceleration and braking, the front eye will be a berlin eye that will place the front spring pin in the horizontal plane within the main leaf.
A steel encased rubber bushing will be used in the spring eye. The steel encased rubber bushing will be maintenance free and require no lubrication.
0000485
Oil Seals, Rear Axle
REAR OIL SEALS
Oil seals will be provided on the rear axle(s).
0782805
Tires, Rear, Goodyear, Armor Max
MSD, 12R22.50, LRH, Single
REAR TIRES
The rear tires will be four (
4 ) Goodyear Armor Max MSD,
12 R
22.50 radials, load range H, rated
for
27,120
lb maximum axle load and
68 mph maximum speed.
0019625
Wheels, Rear, Alcoa, 22.50" x 8.25",
Aluminum, Hub Pilot, Single
The tires will be mounted on Alcoa 22.50" x 8.25" polished aluminum disc wheels with a ten (10) stud 11.25" bolt circle.
0568081
Tire Balancing, Counteract Beads
TIRE BALANCE
All tires will be balanced with Counteract balancing beads. The beads will be inserted into the tire and eliminate the need for wheel weights.
0620570
Tire Pressure Monitoring,
RealWheels, AirSecure, Valve Cap,
Single Axle
TIRE PRESSURE MANAGEMENT
There will be a RealWheels LED AirSecure
™
tire alert pressure management system provided,
that will monitor each tire's pressure. A sensor will be provided on the valve stem of each tire for a total of
six (
6 ) tires
.
The sensor will calibrate to the tire pressure when installed on the valve stem for pressures between
10 and
200
psi. The sensor will activate an integral battery operated LED when the pressure of that tire drops
5 to
8 psi.
Removing the cap from the sensor will indicate the functionality of the sensor and battery. If the sensor and battery are in working condition, the LED will immediately start to flash. 0003245
Axle Hub Covers w/center hole, S/S,
Front Axle
FRONT HUB COVERS
Stainless steel hub covers will be provided on the front axle. An oil level viewing window will be provided.
0001960
Axle Hub Covers, Rear, S/S, High
Hat (Pair)
REAR HUB COVERS
A pair of stainless steel high hat hub covers will be provided on rear axle hubs. 0002045
Mud Flap, Front and Rear, Pierce
Logo
MUD FLAPS
Mud flaps with a Pierce logo will be installed behind the front and rear wheels. 0544802
Chocks, Wheel, SAC-44-E, Folding
WHEEL CHOCKS
There will be
one (
1 ) pair
of folding Ziamatic, Model SAC-
44 -E, aluminum alloy, Quick-Choc
wheel blocks, with easy-grip handle provided.
7 931
Bid #:
0544806
Mounting Brackets, Chocks, SAC-44-
E, Folding, Horizontal
Wheel Chock Brackets
There will be
one (
1 ) pair
of Zico, Model SQCH-
44 -H, horizontal mounting wheel chock brackets
provided for the Ziamatic, Model SAC-
44 -E, folding wheel chocks. The brackets will be made of aluminum and consist of a quick release spring loaded rod to hold the wheel chocks in place. The brackets will be mounted
one (
1 ) forward and one (
1 ) rearward of the left side rear tire
.
0010670
ABS Wabco Brake System, Single
rear axle
ANTI-LOCK BRAKE SYSTEM
The vehicle will be equipped with a Meritor WABCO
4 S
4 M, anti-lock braking system. The ABS
will provide a
4 -channel anti-lock braking control on both the front and rear wheels. A digitally controlled system that utilizes microprocessor technology will control the anti-lock braking system.
Each wheel will be monitored by the system. When any particular wheel begins to lockup, a signal will be sent to the control unit. This control unit then will reduce the braking of that wheel for a fraction of a second and then reapply the brake. This anti-lock brake system will eliminate the lockup of any wheel thus helping to prevent the apparatus from skidding out of control. 0030185
Brakes, Knorr/Bendix 17", Disc,
Front, TAK-4
BRAKES
The service brake system will be full air type.
The front brakes will be Knorr/Bendix disc type with a
17.00 " ventilated rotor for improved
stopping distance.
The brake system will be certified, third party inspected, for improved stopping distance. 0000740
Brakes, Meritor, Cam, Rear, 16.50 x
8.63"
The rear brakes will be Meritor
™ 16.50"
x 8.63" cam operated with automatic slack adjusters.
0735527
Air Compressor, Brake, Wabco 26.8
CI, Paccar
AIR COMPRESSOR, BRAKE SYSTEM
The air compressor will be a Wabco single piston compressor with a
26.8 CI displacement.
0644232
Brake Reservoirs, 4,272 Cubic Inch
Minimum Capacity, Saber
FR/Enforcer
BRAKE SYSTEM
The brake system will include:
Brake treadle valve
Heated automatic moisture ejector on air dryer
Total air system minimum capacity of
4,272
cubic inches
Two (
2 ) air pressure gauges with a red warning light and an audible alarm, that activates when air pressure falls below
60 psi
Spring set parking brake system
Parking brake operated by a push-pull style control valve A parking "brake on" indicator light on instrument panel Park brake relay/inversion and anti-compounding valve, in conjunction with a double check valve system, with an automatic spring brake application at
40 psi
A pressure protection valve to prevent all air operated accessories from drawing air from the air system when the system pressure drops below
80 psi (
550
kPa)
1/4
turn drain valves on each air tank
The air tank will be primed and painted to meet a minimum 750
hour salt spray test.
To reduce the effects of corrosion, the air tank will be mounted with stainless steel brackets. 0587034
Air Dryer, Bendix, AD-IP w/Heat,
2010
BRAKE SYSTEM AIR DRYER
The air dryer will be a Bendix AD-IP, with coalescing filter and heater. 0000790
Brake Lines, Nylon
BRAKE LINES
Color-coded nylon brake lines will be provided. The lines will be wrapped in a heat protective loom in the chassis areas that are subject to excessive heat. 0617799
Inlet/Outlet, Air, w/Disconnect Fitting,
1/4 Turn Valve, Location
AIR INLET/OUTLET
One (
1 ) air inlet/outlet
will be installed with the female coupling located
driver side pump panel
.
This system will tie into the "wet" tank of the brake system and include a check valve in the inlet line and an
85 psi pressure protection valve in the outlet line. The air outlet will be controlled by a 1/4
turn valve.
A mating male fitting will be provided with the loose equipment.
The air inlet will allow a shoreline air hose to be connected to the vehicle. This will allow station air to be supplied to the brake system of the vehicle to insure constant air pressure. 0004200
Hose, Air 25' length, w/air chuck
AIR HOSE
There will be
one (
1 )
25 ' length(s) of air hose furnished with fittings.
An air chuck will be provided with the air hose. The air chuck will fit the valve stems that are provided on the tires.
8 931
Bid #:
0000845
Air Tank, Additional for Extra
Capacity
ADDITIONAL AIR TANK
An additional air tank with
1454
cubic inch displacement will be provided to increase the capacity of the main air brake system. This tank will be plumbed into the rear half of the brake system.
The air tank will be primed and painted to meet a minimum 750
hour spray test. To reduce the
effects of corrosion, the air tank will be mounted with stainless steel brackets.
The output flow of the engine air compressor will vary with engine rpm. Full compressor output will only be achieved at governed engine speed. Engine speed will be limited by generators, pumps and other PTO driven options.
0808515
Engine, Paccar MX, 510HP, 1850 lb-
ftW/OBD, EPA 2027, Enforcer
ENGINE
The chassis will be powered by an electronically controlled engine as described below:
Make:
Paccar
Model:
MX
Power:
510
hp at
1600
rpm
Torque:
1850
lb-ft at
1000
rpm
Governed Speed:
1900
rpm
Emissions Certification:
EPA
2027
Fuel:
Diesel
Cylinders:
Six (
6 )
Displacement:
13.7 L
Starter:
DP
60 Fuel Filters:
Dual cartridge style with check valve, water separator, and water in fuel sensor The engine will include On-board diagnostics (OBD), which provides self diagnostic and reporting. The system will give the owner or repair technician access to state of health information for various vehicle sub systems. The system will monitor vehicle systems, engine and after treatment. The system will illuminate a malfunction indicator light on the dash console if a problem is detected.
0000000
STF
Engine Contingency Adjustment
0001244
High Idle w/Electronic Engine,
Custom
HIGH IDLE
A high idle switch will be provided, inside the cab, on the instrument panel, that will automatically maintain a preset engine rpm. A switch will be installed, at the cab instrument panel, for activation/deactivation.
The high idle will be operational only when the parking brake is on and the truck transmission is in neutral. A green indicator light will be provided, adjacent to the switch. The light will illuminate when the above conditions are met. The light will be labeled "OK to Engage High Idle." 0735687
Engine Brake, Fully Integrated,
Paccar MX13 Engine
ENGINE BRAKE
The compression release brake option is a fully integrated MX engine braking system. It utilizes the turbocharger and backpressure valve, but adds in a hydraulically operated compression brake to increase overall retarding power.
To maximize the effectiveness of the compression brake the MX engine brake system works in conjunction with the turbocharger and back pressure valve.
The driver will be able to turn the engine brake system on/off and have a high, medium and low
setting
0552334
Clutch, Fan, Air Actuated, Horton
Drive Master
CLUTCH FAN
A Horton® fan clutch will be provided. The fan clutch will be automatic when the pump transmission is in "Road" position, and fully engaged in "Pump" position. 0584898
Shutoff Valves, Cab & Crew Cab
Heater, w/Labels
HEATER SHUTOFF
The cab and crew cab heaters will be provided with a shut-off valve installed in the supply line. This valve will be in an accessible location.
Shut-off valve will be labeled for easy recognition.
0644573
Air Intake, Water & Ember Screen,
Saber FR/Enforcer
ENGINE AIR INTAKE
The engine air intake will be located above the engine cooling package. It will draw fresh air from the front of the apparatus through the radiator grille.
The ember separator is designed to prevent road dirt and recirculating hot air from entering the engine.
The ember separator will be easily accessible by tilting the cab. 9 931
Bid #:
0794743
Exhaust System, 5", X12/X15, MX13,
Engine, Horizontal, Right Side
EXHAUST SYSTEM
The exhaust system will include a Single Module
™
aftertreatment device to meet current EPA
standards. The exhaust system will be stainless steel from the turbo to the inlet of the aftertreatment device, and will be
5.00 " in diameter. An insulation wrap will be provided on all exhaust pipes between the turbo and aftertreatment device to minimize the heat loss to the aftertreatment device. The exhaust will terminate horizontally ahead of the right side rear wheels.
A tailpipe diffuser will be provided to reduce the temperature of the exhaust as it exits. Heat deflector shields will be provided to isolate chassis and body components from the heat of the tailpipe diffuser.
0775589
SP
Exhaust, Modified 20 Degree -
Approval Req'd
EXHAUST MODIFICATION
The exhaust pipe will be brought out from under the body at a 20 degree angle to the rear.
The diffuser will not be cut straight to the body, and the outer edge will extend slightly outside of the body. There will be a minimum of
2.50 " from the exhaust pipe to the under side of the body heat shield. The last
7.00 " of the exhaust will be free of hangers and/or clamps. 0788765
Radiator, Saber FR/Enforcer
RADIATOR
The radiator and the complete cooling system will meet or exceed NFPA and engine manufacturer cooling system standards.
For maximum corrosion resistance and cooling performance, the entire radiator core will be constructed using long life aluminum alloy. The radiator core will consist of aluminum fins, having a serpentine design, brazed to aluminum tubes.
The radiator core will have a minimum front area of
1060
square inches.
Supply tank will be made of heavy duty glass-reinforced nylon and the return tank will be mode of aluminum. Both tanks will be crimped onto the core assembly using header tabs and a compression gasket to complete the radiator core assembly. There will be a full steel frame around the inserts to enhance cooling system durability and reliability.
The radiator will be compatible with commercial antifreeze solutions.
The radiator assembly will be isolated from the chassis frame rails with rubber isolators to prevent the development of leaks caused by twisting or straining when the apparatus operates over uneven terrain.
The radiator will include a de-aeration/expansion tank. For visual coolant level inspection, the radiator will have a built-in sight glass. The radiator will be equipped with a 15 psi pressure relief
cap.
A drain port will be located at the lowest point of the cooling system and/or the bottom of the radiator to permit complete flushing of the coolant from the system.
Shields or baffles will be provided to prevent recirculation of hot air to the inlet side of the radiator. 0001090
Cooling Hoses, Rubber
COOLANT LINES
Gates, or Goodyear, rubber hose will be used for all engine coolant lines installed by Pierce Manufacturing.
Hose clamps will be stainless steel constant torque type to prevent coolant leakage. They will expand and contract according to coolant system temperature thereby keeping a constant clamping pressure on the hose.
0001125
Fuel Tank, 65 Gallon, Left Side Fill
FUEL TANK
A
65 gallon fuel tank will be provided and mounted at the rear of the chassis. The tank will be constructed of
12 -gauge, hot rolled steel. It will be equipped with swash partitions and a vent. To eliminate the effects of corrosion, the fuel tank will be mounted with stainless steel straps.
A
0.75 " drain plug will be located in a low point of the tank for drainage.
A fill inlet will be located on the left hand side of the body and is covered with a hinged, spring loaded, stainless steel door that is marked "Ultra Low Sulfur - Diesel Fuel Only." A
0.50 " diameter vent will be installed from tank top to just below fuel fill inlet.
The fuel tank will meet all FHWA
393.67
requirements including a fill capacity of
95 percent of
tank volume.
0001129
Lines, Fuel
All fuel lines will be provided as recommended by the engine manufacturer. 0734655
DEF Tank, 7.3 Gallon, LS Fill, Under
Cab, Paccar, Fill Dr, ENF
DIESEL EXHAUST FLUID TANK
A
7.3 gallon diesel exhaust fluid (DEF) tank will be provided and mounted under the cab on the driver's side.
A fill inlet will be provided on the driver's side of the cab. The door will be vertically hinged and secured by a
lift and turn latch
and be
painted
.
The tank will meet the engine manufacturers requirement for 10 percent expansion space in the
event of tank freezing.
The tank will include an integrated heater unit that utilizes engine coolant to thaw the DEF in the event of freezing.
0552793
Not Required, Fuel Priming Pump
0552712
Not Required, Shutoff Valve, Fuel
Line
10 931
Bid #:
0891206
SP
Cooler, Engine Fuel, Paccar MX13
FUEL COOLER
An air to fuel cooler will be installed in the engine fuel return line. 0690880
No Selection Required From This
Category
0887550
Trans, Allison 6th Gen, 4000 EVS P,
Imp/Vel/Enf
TRANSMISSION
An Allison
6 th generation, model EVS
4000
P, electronic, torque converting, automatic
transmission will be provided.
Two (
2 ) PTO openings will be located on left side and top of converter housing (positions 8 o'clock and
1 o'clock).
A transmission temperature gauge with amber light and buzzer will be installed on the cab instrument panel.
0510877
Transmission, Shifter, 6-Spd, Push
Button w/4+2 mode
TRANSMISSION SHIFTER
A six (
6 )-speed push button shift module with the
4 +
2 "Mode" button will be mounted to right of
driver on console. Shift position indicator will be indirectly lit for after dark operation.
The Allison shifter will be a "double-digit" display model.
The transmission ratio will be
1 st -
3.51 to
1.00 ,
2 nd -
1.91 to
1.00 ,
3 rd -
1.43 to
1.00 ,
4 th -
1.00 to
1.00 ,
5 th -
0.75 to
1.00 ,
6 th -
0.64 to
1.00 , R -
4.80 to
1.00 .
0684459
Transmission Oil Cooler, Modine,
External
TRANSMISSION COOLER
A Modine plate and fin transmission oil cooler will be provided using engine coolant to control the transmission oil temperature.
0001375
Driveline, Spicer 1810
DRIVELINE
Drivelines will be a heavy-duty metal tube and be equipped with Spicer® 1810
universal joints.
The shafts will be dynamically balanced before installation.
A splined slip joint will be provided in each driveshaft where the driveline design requires it. The slip joint will be coated with Glidecoat® or equivalent. 0734211
Steering, Sheppard M110 w/Tilt,
TAK-4, Paccar Pump, w/Cooler,
Paccar
STEERING
Dual Sheppard, Model M
110
, steering gears, with integral heavy-duty power steering, will be provided. For reduced system temperatures, the power steering will incorporate an air to oil cooler and Paccar hydraulic pump with integral pressure and flow control. All power steering lines will have wire braded lines with crimped fittings.
A tilt and telescopic steering column will be provided to improve fit for a broader range of driver configurations.
0803251
Steering Wheel, 4 Spoke w/Wiper
Control & RS Controls, Enforcer, Mux
STEERING WHEEL
The steering wheel will be
18.00 " in diameter, have tilting and telescoping capabilities, and a four (
4 )-spoke design.
There will be a switch pod provided on each side of the steering wheel between the spokes. The switch pods will be an integral part of the steering wheel. The following switches will be provided:
Left pod:
Windshield wash
Wiper intermittent speed increase
Wiper intermittent speed decrease
Hi/Lo wiper speed
Wiper off
Right pod:
Air horn
Area lighting
Front dome light
Rear dome light
0550144
Logo/Emblem, on Horn Button
LOGO AND CUSTOMER DESIGNATION ON HORN BUTTON
The steering wheel will have an emblem containing the Pierce logo and customer name. The emblem will have three (
3 ) rows of text for the customer's department name. There will be a maximum of eight (
8 ) characters in the first row,
11 characters in the second row and
11 characters in the third row.
The first row of text will be:
VISALIA
The second row of text will be:
FIRE
The third row of text will be:
DEPARTMENT
0606186
Bumper, Non-Extended, Saber
FR/Enforcer
BUMPER
A one (
1 ) piece, ten (
10 ) gauge
304-2
B polished stainless steel bumper, minimum of
10.00 " high,
will be attached to the front of the chassis frame.
A
9.00 " formed steel channel will be mounted directly behind bumper for additional strength.
Gravel Pan
A gravel pan, constructed of bright aluminum treadplate, will be furnished between the bumper and cab face.
11 931
Bid #:
0778092
Lift & Tow Package, Enforcer
LIFT AND TOW MOUNTS
Mounted to the frame extension will be lift and tow mounts. The lift and tow mounts will be designed and positioned to adapt to certain tow truck lift systems.
The lift and tow mounts with eyes will be painted the same color as the frame. 0522573
Tow Hooks Not Required, Due to Lift
and Tow Package
TOW HOOKS
No tow hooks are to be provided. This truck will be equipped with a lift and tow package with integral tow eyes.
0888084
SP
Lights, Fog, PIAA RF6 (07206) LED,
Rectangular, pair, Recessed into
Bumper
FOG LIGHTS
There will be two (
2 ) PIAA, Model RF
6 , Part
#07206
LED fog lamps provided, one (
1 ) on each
side recessed into the front bumper.
The fog lamp switch will include an internal indicator. The switch will be properly identified and installed on the switch panel within reach of the driver. The parking, tail, side marker and license plate lamps will be activated by the headlamp switch prior to the activation of these fog lights. The fog lights will be able to switch on or off independently of the low beam headlights. The front fog lights will be reset to an off position whenever the headlight switch or the vehicle ignition switch is set to the off position. The fog lights will be deactivated when the high beam headlights are activated, when the headlight switch is turned off or when the ignition switch is turned off. 12 931
Bid #:
0648332
Cab, Enforcer, 7010
CAB
The Enforcer cab will be designed specifically for the fire service and manufactured by the chassis builder.
The cab will be built by the apparatus manufacturer in a facility located on the manufacturer's premises.
For reasons of structural integrity and enhanced occupant protection, the cab will be a heavy duty design, constructed to the following minimal standards.
The cab will have
12 main vertical structural members located in the A-pillar (front cab corner posts), B-pillar (side center posts), C-pillar (rear corner posts), and rear wall areas. The A-pillar will be constructed of solid A
356
-T
5 aluminum castings. The B-pillar and C-pillar will be
constructed from
0.13 " wall extrusions. The rear wall will be constructed of two ( 2 )
2.00 " x
2.00 "
outer aluminum extrusions and two (
2 )
2.00 " x
1.00 " inner aluminum extrusions. All main vertical
structural members will run from the floor to
4.625
" x
3.864
" x
0.090
" thick roof extrusions to
provide a cage-like structure with the A-pillar and roof extrusions being welded into a
0.25 " thick
corner casting at each of the front corners of the roof assembly.
The front of the cab will be constructed of a
0.13 " firewall plate, covered with a
0.090
" front skin
(for a total thickness of
0.22 "), and reinforced with a full width x
0.50 " thick cross-cab support
located just below the windshield and fully welded to the engine tunnel. The cross-cab support will run the full width of the cab and weld to each A-pillar, the
0.13 " firewall plate, and the front
skin.
The cab floors will be constructed of
0.125
" thick aluminum plate and reinforced at the firewall
with an additional
0.25 " thick cross-floor support providing a total thickness of
0.375
" of structural
material at the front floor area. The front floor area will also be supported with two ( 2 ) triangular
0.30 " wall extrusions that also provides the mounting point for the cab lift. This tubing will run from the floor wireway of the cab to the engine tunnel side plates, creating the structure to support the forces created when lifting the cab.
The cab will be
96.00 " wide (outside door skin to outside door skin) to maintain maximum maneuverability.
The forward cab section will have an overall height (from the cab roof to the ground) of approximately
99.00 ". The crew cab section will have a
10.00 " raised roof, with an overall cab
height of approximately
109.00
". The overall height listed will be calculated based on a truck configuration with the lowest suspension weight rating, the smallest diameter tires for the suspension, no water weight, no loose equipment weight, and no personnel weight. Larger tires, wheels, and suspension will increase the overall height listed.
The floor to ceiling height inside the crew cab will be
64.50 " in the center and outboard positions.
The crew cab floor will measure
46.00 " from the rear wall to the back side of the rear facing seat risers.
The medium block engine tunnel, at the rearward highest point (knee level), will measure
61.50 "
to the rear wall. The big block engine tunnel will measure
51.50 " to the rear wall.
The crew cab will be a totally enclosed design with the interior area completely open to improve visibility and verbal communication between the occupants.
The cab will be a full tilt cab style.
A
3 -point cab mount system with rubber isolators will improve ride quality by isolating chassis vibrations from the cab.
CAB ROOF DRIP RAIL
For enhanced protection from inclement weather, a drip rail will be furnished on the sides of the cab. The drip rail will be painted to match the cab roof, and bonded to the sides of the cab. The drip rail will extend the full length of the cab roof.
INTERIOR CAB INSULATION
The cab will include
1.00 " insulation in the ceiling,
1.50 " insulation in the side walls, and
2.00 "
insulation in the rear wall to maximize acoustic absorption and thermal insulation.
FENDER LINERS
Full circular inner fender liners in the wheel wells will be provided.
PANORAMIC WINDSHIELD
A one (
1 )-piece safety glass windshield will be provided with over 2,775
square inches of clear
viewing area. The windshield will be full width and will provide the occupants with a panoramic view. The windshield will consist of three (
3 ) layers: outer light, middle safety laminate, and inner light. The outer light layer will provide superior chip resistance. The middle safety laminate layer will prevent the windshield glass pieces from detaching in the event of breakage. The inner light will provide yet another chip resistant layer. The cab windshield will be bonded to the aluminum windshield frame using a urethane adhesive. A custom frit pattern will be applied on the outside perimeter of the windshield for a finished automotive appearance.
WINDSHIELD WIPERS
Three (
3 ) electric windshield wipers with washer will be provided that meet FMVSS and SAE requirements.
The washer reservoir will be able to be filled without raising the cab. 0747442
Engine Tunnel, X12, MX13, Enforcer
ENGINE TUNNEL
Engine hood side walls will be constructed of
0.375
" aluminum. The top will be constructed of
0.125
" aluminum and will be tapered at the top to allow for more driver and passenger elbow room.
The engine hood will be insulated for protection from heat and sound. The noise insulation keeps the dBA level within the limits stated in the current NFPA 1901
standards.
The engine tunnel will be no higher than
17.00 " off the crew cab floor.
0633594
Rear Wall, Interior, Adjustable
Seating
INTERIOR CREW CAB REAR WALL ADJUSTABLE SEATING (PATENT PENDING) The interior rear wall of the crew cab will have mounting holes every
2.75 " to allow for
adjustability of the forward facing crew cab seating along the rear wall. Seats will be adjustable with use of simple hand tools allowing departments flexibility of their seating arrangement should their department needs change.
13 931
Bid #:
0632103
Rear Wall, Exterior, Cab, Saber
FR/Enforcer
CAB REAR WALL EXTERIOR COVERING
The exterior surface of the rear wall of the cab will be overlaid with bright aluminum treadplate
except for areas that are not typically visible when the cab is lowered .
0622582
Cab Lift, Elec/Hyd, Manual Override,
Control Loc Feature, Sab FR/Enf
CAB LIFT
A hydraulic cab lift system will be provided consisting of an electric powered hydraulic pump, dual lift cylinders, and necessary hoses and valves.
Hydraulic pump will have a manual override for backup in the event of electrical failure.
Lift controls will be located
Left Side Pump Panel (Match Job
33716
)
.
The cab will be capable of tilting
43 degrees to accommodate engine maintenance and removal.
The cab will be locked down by a
2 -point normally closed spring loaded hook type latch that fully engages after the cab has been lowered. The system will be hydraulically actuated to release the normally closed locks when the cab lift control is in the raised position and cab lift system is under pressure. When the cab is completely lowered and system pressure has been relieved, the spring loaded latch mechanisms will return to the normally closed and locked position.
The hydraulic cylinders will be equipped with a velocity fuse that protects the cab from accidentally descending when the control is located in the tilt position.
For increased safety, a redundant mechanical stay arm will be provided that must be manually put in place on the left side between the chassis and cab frame when the cab is in the raised position. This device will be manually stowed to its original position before the cab can be lowered.
Cab Lift Interlock
The cab lift system will be interlocked to the parking brake. The cab tilt mechanism will be active only when the parking brake is set and the ignition switch is in the on position. If the parking brake is released, the cab tilt mechanism will be disabled. 0695930
Grille, Bright Finished, Front of Cab,
Enforcer
GRILLE
A bright finished aluminum mesh grille screen, inserted behind a bright finished grille surround, will be provided on the front center of the cab.
0776102
SP
Scuffplates, Officers Cab Step Compt
STEP WELL COMPARTMENT SCUFFPLATE
The officer cab step well compartment will have
polished stainless steel
scuffplate around the
opening of the compartment.
0002224
Scuffplates, S/S At Cab Door Jambs,
4-Door Cab
DOOR JAMB SCUFFPLATES
All cab door jambs will be furnished with a
1.00 "
polished stainless steel
scuffplate, mounted on
the striker side of the jamb.
0721921
SP
Scuffplate, Top and Edge of Rear
Engine Tunnel, 1.50"
ENGINE TUNNEL SCUFFPLATE
A
bright aluminum treadplate
scuffplate will be installed along the top rear edge of engine tunnel, flanged down to protect the edge of the engine tunnel. The scuffplate will extend
1.50 " on the top
and rear of the engine tunnel.
0647932
Not Required, Trim, S/S Band,
Across Cab Face,
AXT/Saber/Enforcer
0015440
No Chrome Molding, On side of cab
0521669
Mirrors, Retrac, West Coast Style,
Htd/Rmt, w/Htd/Rmt Convex
MIRRORS
A Retrac, Model
613423
, dual vision, motorized, west coast style mirror, with chrome finish, will be mounted on each side of the front cab door with spring loaded retractable arms. The flat glass and convex glass will be heated and adjustable with remote control within reach of the driver. 14 931
Bid #:
0648172
Door, Full Height, Saber FR/Enforcer
4-Door Cab, Raised Roof
DOORS
To enhance entry and egress to the cab, the forward cab doors will be a minimum of
37.50 " wide
x
75.50 " high. The crew cab doors will be located on the sides of the cab and will be constructed in the same manner as the forward cab doors. The crew cab door openings will be a minimum of
34.30 " wide x
85.50 " high.
The forward cab and crew cab doors will be constructed of extruded aluminum with a nominal material thickness of
0.093
". The exterior door skins will be constructed from
0.090
" aluminum.
A customized, vertical, pull-down type door handle will be provided on the exterior of each cab door. The finish of the door handle will be
chrome/black
. The exterior handle will be designed
specifically for the fire service to prevent accidental activation, and will provide
4.00 " wide x
2.00 "
deep hand clearance for ease of use with heavy gloved hands.
Each door will also be provided with an interior flush, open style paddle handle that will be readily operable from fore and aft positions, and be designed to prevent accidental activation. The interior handles will provide
4.00 " wide x
1.25 " deep hand clearance for ease of use with heavy
gloved hands.
The cab doors will be provided with both interior (rotary knob) and exterior (keyed) locks exceeding FMVSS standards. The keys will be Model
751
. The locks will be capable of activating
when the doors are open or closed. The doors will remain locked if locks are activated when the doors are opened, then closed.
A full length, heavy duty, stainless steel, piano-type hinge with a
0.38 " pin and
11 gauge leaf will
be provided on all cab doors. There will be double automotive-type rubber seals around the perimeter of the door framing and door edges to ensure a weather-tight fit.
A chrome grab handle will be provided on the inside of each cab door for ease of entry.
A red webbed grab handle will be installed on the crew cab door stop strap. The grab handles will be securely mounted.
The cab steps at each cab door location will be located inside the cab doors to protect the steps from weather elements.
0655543
Door Panel, Brushed Stainless Steel,
Saber/Enforcer 4-Door Cab
Door Panels
The inner cab door panels will be constructed out of brushed stainless steel. 0630636
Controls, Electric Roll-Up Windows,
4dr, 4 Driver Controls, Saber
FR/Enforcer
ELECTRIC OPERATED CAB DOOR WINDOWS
All four (
4 ) cab doors will be equipped with electric operated windows with one ( 1 ) flush mounted
automotive style switch on each door. The driver's door will have four ( 4 ) switches, one (
1 ) to
control each door window.
Each switch will allow intermittent or auto down operation for ease of use. Auto down operation will be actuated by holding the window down switch for approximately 1 second.
0528251
Electric Door Locks, Cab Doors,
QXS, AXT, Sab, Enf, Dash CF
ELECTRIC CAB DOOR LOCKS
The front driver and officer doors will have a door lock master switch that will control all front and rear crew cab door locks. Each rear crew cab door will have its own lock control.
There will be one (
1 ) concealed switch located in an easily accessible chassis specific location that will unlock all the doors.
0633615
Steps, 4-Door Cab, Reduced Bottom
Step, Saber FR/Enforcer
CAB STEPS
The forward cab and crew cab access steps will be a full size two ( 2 ) step design to provide
largest possible stepping surfaces for safe ingress and egress. The bottom steps will be designed with a grip pattern punched into bright aluminum treadplate material to provide support, slip resistance, and drainage. The bottom steps will be a bolt-in design to minimize repair costs should they need to be replaced. The forward cab steps will be a minimum
25.00 " wide, and the
crew cab steps will be
21.65 " wide with an
8.00 " minimum depth. The inside cab steps will not
exceed
16.50 " in height.
The vertical surfaces of the step well will be
aluminum treadplate
.
0770194
Handrail, Exterior, Knurled, Alum, 4-
Door Cab
CAB EXTERIOR HANDRAILS
A
1.25 " diameter slip-resistant, knurled aluminum handrail will be provided adjacent to each cab and crew cab door opening to assist during cab ingress and egress. 0560452
Steps, Stirrup, Formed, Cab & Crew
Cab Doors, AXT/SFR/Enf
STIRRUP STEPS
A stirrup step will be provided below each cab and crew cab door. The steps will be designed with a grip pattern punched into bright aluminum treadplate material providing support, slip resistance, and drainage. The steps will be a bolt-on design and provide a
5.00 " deep stepping surface. Each
step will provide a step height of
8.25 " from the top of the stirrup step to the first step of the cab.
The stirrup step will be lit by
a white
12 volt DC LED light provided on the step.
The step light will be activated automatically when the battery switch is on and the exit doors are opened or by the same means as the body step lights.
15 931
Bid #:
0892638
Lights, Cab & Crw Cab Acs Stps,
P25, LED w/Bezel, 6lts
STEP LIGHTS
There will be six (
6 ) white LED step lights with
chrome housing
installed for cab and crew cab
access steps.
One (
1 ) light for the left access steps.
Two (
2 ) lights for the left side crew cab access steps.
Two (
2 ) lights for the right side crew cab access steps.
One (
1 ) light for the right side access step.
In order to ensure exceptional illumination, each light will provide a minimum of 25 foot-candles
(fc) covering an entire
15 " x
15 " square placed ten (
10 ) inches below the light and a minimum of
1.5 fc covering an entire
30 " x
30 " square at the same ten (
10 ) inch distance below the light.
The lights will be activated when the battery switch is on and the adjacent door is opened. 0005772
Fenders, S/S on cab, w/Radius
corner, 2.00" wide
FENDER CROWNS
Stainless steel fender crowns will be installed at the cab wheel openings. The fender crowns will have a radius outside corner that will allow the fender crown to extend out further than the standard width crown, thus extending beyond the sidewall of the front tires and allow the crew cab doors to open fully.
0042105
No Windows, Side of Crew Cab
0012090
Not Required, Windows, Front/Side
of raised roof
0779033
Not Required, Windows Rear of Crew
Cab, Saber FR/Enforcer
0786279
Window Tint, Crew Cab Door, Right
Side, Privacy Dark Gray
RIGHT SIDE ROLLUP CREW CAB DOOR WINDOW TINT
The rollup window in the right side crew cab door will be tinted privacy dark gray. 0786286
Window Tint, Upper Crew Cab Door,
Right Side, Privacy Dark Gray
RIGHT SIDE UPPER CREW CAB DOOR WINDOW TINT
The upper window in the right side crew cab door will be tinted privacy dark gray. 0786290
Window Tint, Crew Cab Door, Left
Side, Privacy Dark Gray
LEFT SIDE ROLLUP CREW CAB DOOR WINDOW TINT
The rollup window in the left side crew cab door will be tinted privacy dark gray. 0786294
Window Tint, Upper Crew Cab Door,
Left Side, Privacy Dark Gray
LEFT SIDE UPPER CREW CAB DOOR WINDOW TINT
The upper window in the left side crew cab door will be tinted privacy dark gray. 0809780
SP
Compt, 15 W x 14.5 LS/24.5 RS H x
15 D, Ea Side CC, Dbl Pan, DEF, 70"
Enf
STORAGE COMPARTMENTS
Provided on each side of the cab, to the rear of the crew cab access doors, will be a storage compartment.
The left side compartment will be
15.00 " wide x
14.50 " high x
15.00 " deep and located above the
DEF fill door.
The right side compartment will be
15.00 " wide x
24.50 " high x
15.00 " deep.
There will be
two (
2 ) double pan doors painted to match the cab exterior with a locking D-Ring latch with
#751
key, one (
1 ) on each side of the cab
. A
rubber bumper for each exterior door
will
be used as a doorstop.
The compartment interior will be
painted to match the cab interior
.
Compartment Lights
There will be
two (
2 ) white LED strip lights provided, one (
1 ) each hinged side of compartment
door openings
. Any lighting will be controlled by an automatic door switch. 0811700
SP
Compt, Officers Step, SFR/Enf
STORAGE COMPARTMENT
Provided on the officer's side of the cab, in the step area, will be a storage compartment. The compartment will be
11.50 " wide x
9.50 " high x
11.50 " deep. The compartment will have a drop
down hinged treadplate door with a D-ring handle. The compartment will be painted to match the
cab interior
.
0553057
Holder, Cup, Cab/Crewcab, Each
CUP HOLDER
There will be
two (
2 )
cup holder(s) provided. Each cup holder will have self-adjusting fingers that automatically grip beverage containers of various sizes. A recess in the cup holder will allow it to hold beverage containers with handles.
The cup holder(s) will be located at customer pick-up.
16 931
Bid #:
0894089
Dash, Heavy Duty Metal, Enforcer
CAB DASH
The driver side dash, switch panel located to the right of the driver, and center console will be constructed of aluminum and
painted fire smoke gray
.
The officer side dash will be a flat top design with an upper beveled edge to provide easy maintenance and will be constructed out of aluminum and painted to match the cab interior.
The instrument gauge cluster will be surrounded with a high impact ABS plastic contoured to the same shape of the instrument gauge cluster.
0657958
Bracket, Air Bottle, Zico, ULLH-EZO,
Load & Lock
AIR BOTTLE HOLDER(S)
There will be
one (
1 )
Ziamatic, Model ULLH-EZO, SCBA holder(s) with a LLS, collision restraint holding strap, provided in the crew cab. The bracket(s) will be located in the cab on the rear wall
and outboard on the driver side, match job
33716
.
0763603
SP
Computer Mount, Gamber Johnson
Mongoose, Toughbook 30
UNIVERSAL COMPUTER MOUNT
There will be
one (
1 )
universal computer mount(s) with a Mongoose
™
9 " locking slide arm and
Toughbook
30 mounting interface plate located
one (
1 ) in the recessed area of dash forward of
the officer seat
.
A
12 volt DC,
15 amp power point will be provided near the mount.
The following Gamber Johnson components will be provided:
One (
1 )
7160-0220
Mongoose
™
9 " locking slide arm
One (
1 )
7160-0043
Toughbook
30 mounting interface plate
0750824
Cab Interior, Vinyl Headliner, Saber
FR/Enforcer, CARE
CAB INTERIOR
The cab interior will be constructed of primarily metal (painted aluminum) to withstand the severe duty cycles of the fire service.
The engine tunnel will be
painted aluminum to match the cab interior
.
For durability and ease of maintenance, the cab interior side walls will be painted aluminum. The rear wall will be
painted aluminum
.
The headliner will be installed in both forward and rear cab sections. Headliner material will be vinyl. A sound barrier will be part of its composition. Material will be installed on an aluminum sheet and securely fastened to interior cab ceiling.
The forward portion of the cab headliner will permit easy access for service of electrical wiring or other maintenance needs.
All wiring will be placed in metal raceways.
CAB INTERIOR UPHOLSTERY
The cab interior upholstery will be
36 oz dark silver gray vinyl
.
0753903
Cab Interior, Paint Color, Saber
FR/Enforcer
CAB INTERIOR PAINT
The cab interior metal surfaces, excluding the rear heater panels, will be painted fire smoke gray,
vinyl texture paint
.
The rear heater panels will be painted black, vinyl textured paint. 0052100
Floor, Rubber Padded, Cab & Crew
Cab, Saber/Enforcer
CAB FLOOR
The cab and crew cab floor areas will be covered with Polydamp ™
acoustical floor mat consisting
of a black pyramid rubber facing and closed cell foam decoupler.
The top surface of the material has a series of raised pyramid shapes evenly spaced, which offer a superior grip surface. Additionally, the material has a
0.25 " thick closed cell foam (no water
absorption) which offers a sound dampening material for reducing sound levels. 17 931
Bid #:
0722696
HVAC, Enforcer, CARE
DEFROST/AIR CONDITIONING SYSTEM
A ceiling mounted combination heater, defroster and air conditioning system will be installed in the cab above the engine tunnel area.
Cab Defroster
A
54,000
BTU heater-defroster unit with
690
SCFM of air flow will be provided inside the cab. The
heater-defrost will be installed in the forward portion of the cab ceiling. Air outlets will be strategically located in the cab header extrusion per the following:
One (
1 ) adjustable will be directed towards the left side cab window One (
1 ) adjustable will be directed towards the right side cab window Six (
6 ) fixed outlets will be directed at the windshield
The defroster will be capable of clearing
98 percent of the windshield and side glass when tested under conditions where the cab has been cold soaked at
0 degrees Fahrenheit for
10 hours, and
a
2 ounce per square inch layer of frost/ice has been able to build up on the exterior windshield.
The defroster system will meet or exceed SAE J
382
requirements.
Cab/Crew Auxiliary Heater
There will be
one (
1 )
31,000
BTU auxiliary heater with
560
SCFM of air flow provided in each
outboard rear facing seat risers with a dual scroll blower. An aluminum plenum incorporated into the cab structure used to transfer heat to the forward positions .
Air Conditioning
A condenser will be a
59,644
BTU output that meets and exceeds the performance specification will be mounted on the radiator.
The air conditioning system will be capable of cooling the average cab temperature from 100
degrees Fahrenheit to
75 degrees Fahrenheit at
50 percent relative humidity within
30 minutes.
The cooling performance test will be run only after the cab has been heat soaked at 100
degrees
Fahrenheit for a minimum of
4 hours.
The evaporator unit will be installed in the rear portion of the cab ceiling over the engine tunnel.
The evaporator will include one (
1 ) high performance heating core, one (
1 ) high performance
cooling core with (
1 ) plenum directed to the front and one (
1 ) plenum directed to the rear of the
cab. The rear plenum will be covered with
a metal cover painted to match the cab interior
.
The evaporator unit will have a
52,000
BTU at
690
SCFM rating that meets and exceeds the
performance specifications.
Adjustable air outlets will be strategically located on the forward plenum cover per the following:
Four (
4 ) will be directed towards the seating position on the left side of the cab Four (
4 ) will be directed towards the seating position on the right side of the cab Adjustable air outlets will be strategically located on the rear plenum cover per the following:
Minimum of five (
5 ) will be directed towards crew cab area
A high efficiency particulate air (HEPA) filter will be included for the system. Access to the filter cover will be
secured with four (
4 ) screws
.
The air conditioner refrigerant will be R-
134
A and will be installed by a certified technician.
Climate Control
An automotive style controller will be provided to control the heat and air conditioning system within the cab. The controller will have three (
3 ) functional knobs for fan speed, temperature, and
air flow distribution (front to rear) control.
The system will control the temperature of the cab and crew cab automatically by pushing the center of the fan speed control knob. Rotate the center temperature control knob to set the cab and crew cab temperature.
The AC system will be manually activated by pushing the center of the temperature control knob.
Pushing the center of the air flow distribution knob will engage the AC for max defrost, setting the fan speeds to
100
percent and directing all air flow to the overhead forward position.
The system controller will be located
within panel position
#13
.
Gravity Drain Tubes
Two (
2 ) condensate drain tubes will be provided for the air conditioning evaporator. The drip pan will have two (
2 ) drain tubes plumbed separately to allow for the condensate to exit the drip pan.
No pumps will be provided.
0639675
Sun Visor, Smoked Lexan, AXT,
Imp/Vel, Saber FR/Enforcer
SUN VISORS
Two (
2 ) smoked Lexan
™
sun visors will be provided. The sun visors will be located above the windshield with one (
1 ) mounted on each side of the cab.
There will be
a black plastic thumb latch
provided to help secure each sun visor in the stowed
position.
0634328
Grab Handles, Driver and Officer
Door Posts, Saber FR/Enforcer
GRAB HANDLES
A black rubber covered grab handle will be mounted on the door post of the driver and officer's side cab door to assist in entering the cab. The grab handles will be securely mounted to the post area between the door and windshield.
0583938
Lights, Engine Compt, Custom, Auto
Sw, Wln 3SC0CDCR, 3" LED, Trim
ENGINE COMPARTMENT LIGHTS
There will be
one (
1 )
Whelen, Model
3 SC
0 CDCR,
12 volt DC,
3.00 " white LED light(s) with
Whelen, Model
3 FLANGEC, chrome flange kit(s) installed under the cab to be used as engine compartment illumination.
These light(s) will be activated automatically when the cab is raised. 0631830
Fluid Check Access, Saber
FR/Enforcer, Arrow XT
ACCESS TO ENGINE DIPSTICKS
For access to the engine oil and transmission fluid dipsticks, there will be a door on the engine tunnel, inside the crew cab. The door will be on the rear wall of the engine tunnel, on the vertical surface.
The engine oil dipstick will allow for checking only. The transmission dipstick will allow for both checking and filling.
The door will have a rubber seal for thermal and acoustic insulation. One ( 1 )
flush lift and turn
latch
will be provided on the access door.
18 931
Bid #:
0002505
Map box, 3 bin, Open from Top,
Custom Chassis
MAP BOX
There will be
one (
1 )
map box(es) with three (
3 ) bins, open at top, installed
installed at final
inspection
. The map box will be divided into three (
3 ) bins, each being
12.00 " wide x
4.00 " deep x
8.00 " high. The map box will be constructed of .
125
" aluminum and will be painted to match the
cab interior.
0583041
Side Roll Protection
SIDE ROLL PROTECTION
The cab will be provided with a side roll protection system and will include the following:
A supplemental restraint system (SRS) sensor will be installed on a structural cab member behind the instrument panel. The SRS sensor will perform real time diagnostics of all critical subsystems and will record sensory inputs immediately before and during a side roll event.
A slave SRS sensor will be installed in the cab to provide capacity for eight ( 8 ) crew cab seating
positions.
A fault-indicating light will be provided on the vehicle's instrument panel allowing the driver to monitor the operational status of the SRS system.
Air curtains will be provided in the outboard bolster of outboard seat backs to provide a cushion between occupant and the cab wall.
Suspension seats will be provided with devices to retract them to the lowest travel position during a side roll event.
Seat belts will be provided with pre-tensioners to remove slack from the seat belt during a side roll event.
The SRS system will provide protection during a fast or slow 90 -degree roll to the side, in which
the vehicle comes to rest on its side. The system will analyze the vehicle's angle and rate of roll to determine the optimal activation of the advanced occupant restraints.
The SRS system will deploy the following components in the event of a side roll:
Air curtains mounted in the outboard bolster of outboard seat backs.
Suspension seats will be retracted to the lowest travel position.
Seat belts will be pre-tensioned to firmly hold the occupant in place. 0622619
Seating Capacity, 4 Seats
SEATING CAPACITY
The seating capacity of the vehicle (including tiller cab and belted seat positions in the rescue body) will be four (
4 ).
0766159
Seat, Driver, USSC, Valor, P1A, Air
Ride, I-Back, Safety, Saber
FR/Enforcer
DRIVER SEAT
A USSC Valor air suspension I-back seat will be provided in the cab for the driver. For increased convenience, the seat will include a manual control to adjust the horizontal position (
6.00 " travel).
To provide flexibility for multiple driver configurations, the seat will have a reclining back, adjustable from
15 degrees back to
15 degrees forward.
The seat will include the following features incorporated into the side roll protection system:
Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position.
A suspension seat safety system will be included. When activated in the event of a side roll, this system will pretension the seat belt and retract the seat to its lowest travel position.
Shipped loose with the seat will be
no additional contaminant mitigation vinyl covers
.
The seat will be furnished with a
3 -point, shoulder type seat belt.
0795050
Seat, Officer, USSC, Valor, P1A, Air
Ride, SCBA, Safety, Saber
FR/Enforcer
OFFICER SEAT
A USSC, P
1 A, SCBA air suspension seat will be provided in the cab for the officer. For optimal comfort, the seat will be provided with
17.00 " deep cushion. For increased convenience, the seat will include a manual control to adjust the height (
3.00 " travel) and horizontal position (
4.25 "
travel).
The seat back will be an SCBA back style with
5 degree fixed recline angle. The SCBA cavity will
be adjustable from front to rear in
0.75 " increments, to accommodate different sized SCBA
cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location.
The seat will include the following features incorporated into the side roll protection system:
Side air curtain will be mounted integral to the outboard bolster of the seat back. The air curtain will be covered by a decorative panel when in the stowed position.
A suspension seat safety system will be included. When activated, this system will pretension the seat belt and then retract the seat to its lowest travel position.
The seat will be furnished with a
3 -point, shoulder type seat belt.
Shipped loose with the seat will be
no additional contaminant mitigation vinyl covers
.
0002517
Not Required, Radio Compartment
19 931
Bid #:
0896904
SP
Cabinet, Rear Facing, LS, 23.5 W x
30 H x 26.75 D, Roll, Ext Acc,
SFR/Enf
REAR FACING LEFT SIDE CABINET
A rear facing cabinet will be provided in the crew cab at the left side outboard position.
The cabinet will be
23.50 " wide x
30.00 " high x
26.75 " deep with
one (
1 ) Gortite rollup door with
satin anodized finish, non-locking
. The frame to frame opening will be
18.50 " wide x
24.75 " high.
The minimum clear door opening of the cabinet will be
15.25 " wide x
18.87 " high.
The cabinet will also provide access from outside the cab with one (
1 ) double pan door painted to
match the cab exterior with a locking D-ring latch with #751
key
. A
pneumatic stay arm
will be
provided as a door stop. The door will be located on the side of the cab over the wheelwell. The clear door opening will be
17.00 " wide x
26.00 " high.
The cabinet will include
one (
1 ) infinitely adjustable shelf with a
1.25 " up-turned lip
painted to
match the cab interior
.
The cabinet will include
no louvers
.
The exterior access will be provided with
a polished stainless steel scuffplate
on the lower door
frame.
The cabinet will be constructed of smooth aluminum and painted to match the cab interior.
Cabinet Light
There will be
one (
1 ) white Amdor LED strip light installed on the right side of the interior cabinet door opening
. The lights will be controlled by an automatic door switch. 0102783
Not Required, Seat, Rr Facing C/C,
Center
0896906
SP
Cabinet, Rear Facing, RS, 23.5 W x
30 H x 26.75 D, Roll, Ext Acc,
SFR/Enf
REAR FACING RIGHT SIDE CABINET
A rear facing cabinet will be provided in the crew cab at the right side outboard position.
The cabinet will be
23.50 " wide x
30.00 " high x
26.75 " deep with
one (
1 ) Gortite rollup door with
satin anodized finish, non-locking
. The frame to frame opening will be
18.50 " wide x
24.5 " high.
The minimum clear door opening of the cabinet will be
15.25 " wide x
18.87 " high.
The cabinet will include
one (
1 ) infinitely adjustable shelf with a
1.25 " up-turned lip
painted to
match the cab interior
.
The cabinet will include
no louvers
.
The cabinet will also provide access from outside the cab with one (
1 ) double pan door painted to
match the cab exterior with a locking D-ring latch with #751
key
. A
pneumatic stay arm
will be
provided as a door stop. The exterior clear door opening will be
17.00 " wide x
26.00 " high.The
exterior access will be provided with
a polished stainless steel scuffplate
on the lower door frame.
The cabinet will be constructed of smooth aluminum, and painted to match the cab interior.
Cabinet Light
There will be
one (
1 ) white Amdor LED strip light installed on the left side of the interior cabinet door opening
. The lights will be controlled by an automatic door switch. 0108189
Not Required, Seat, Forward Facing
C/C, DS Outboard
0734358
SP
Seat, Fwd Facing C/C, Ctr, (2) USSC,
Valor,SCBA,95 D,Safety,8.25"
Sp,SFR/Enf PUC
FORWARD FACING CENTER SEATS
There will be two (
2 ) forward facing, USSC Valor seats provided at the center position in the crew cab. The seats will be spaced an additional
8.25 " apart to provide more room for each occupant.
For optimal comfort, the seats will be provided with a
15.00 " deep foam cushion.
The seat backs will be an SCBA style with
95 degree back. The SCBA cavity will be adjustable
from front to rear in
0.75 " increments to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location.
The seat will include the following features incorporated into the side roll protection system:
A seat safety system will be included. When activated, this system will pretension the seat belt.
The seats will be furnished with a
3 -point, shoulder type seat belt.
0108190
Not Required, Seat, Forward Facing
C/C, PS Outboard
0752005
Lip, Top of Interior Cabinet, All Sides
LIP ON CABINET
There will be a
2.00 "
lip provided around the top perimeter of the cabinet. There will NOT be anything stored on the top portion without restraints
There will be
two (
2 )
cabinets(s) provided with the lip
REAR FACING EMS CABINETS
.
0749925
SP
Compt, Storage, (2) Rear Facing,
Overhead, 21 W x 10 H x 12 D,
Saber FR/Enforcer
REAR FACING OVERHEAD STORAGE CABINETS
There will be two (
2 ) overhead rear facing storage cabinets installed at the raised roof within the crew cab, on each side of the air conditioner. The cabinets will be approximately
21.00 " wide x
10.00 " high x
12.00 " deep at the bottom.
Each cabinet will include one (
1 ) liftup cabinet door.
Non-locking latch
, paddle handle, and gas
operated stay arms will be provided.
The cabinet will be constructed of smooth aluminum and painted to match the cab interior.
Cabinet Light
There will be
one (
1 ) white LED strip light installed horizontally above each compartment door opening
. The lights will be controlled by an automatic door switch. 20 931
Bid #:
0732620
SP
Cabinet, Rear Facing, Top Eng Tnl,
43 W x 18 H x 16 D, Web, Notch,
SFR/Enf
REAR FACING CENTER CABINET
A rear facing cabinet will be provided on the top rear of the engine tunnel.
The cabinet will be
43.00 " wide x
18.00 " high x
16.00 " deep. The back of the cabinet will taper to
match the angle of the tunnel so that the front of the cabinet is flush with the rear of the engine tunnel. The back corners of the cabinet will be notched around the gravity drains.
The interior door will be web netting. The netting will be made with
1.00 " wide nylon material with
2.00 " openings. The nylon webbing will be permanently fastened at the bottom
side of the cabinet
and have
spring clip and hook
fasteners on the opposite side to secure it. The clear door opening of the cabinet will be
40.50 " wide x
15.00 " high.
The cabinet will include
one (
1 ) infinitely adjustable shelf with a
1.25 " up-turned lip
painted to
match the cab interior
.
The cabinet will be constructed of smooth aluminum, and painted to match the cab interior.
Cabinet Light
There will be
one (
1 ) white Amdor LED strip light installed on the right side of the interior cabinet door opening and one (
1 ) white Amdor LED strip light installed on the left side of the interior cabinet door opening
. The light will be controlled by a rocker switch on the front of the cabinet. 0625186
Upholstery, Seats In Cab, All
ValorTechXD (Cordura), USSC,
CARE
SEAT UPHOLSTERY
All seat upholstery will be
gray, sewn with black stitching,
ValorTechXD anti-microbial material.
0543991
Bracket, Air Bottle, Hands-Free II,
Cab Seats
AIR BOTTLE HOLDERS
All SCBA type seats in the cab will have a "Hands-Free" auto clamp style bracket in its backrest.
For efficiency and convenience, the bracket will include an automatic spring clamp that allows the occupant to store the SCBA bottle by simply pushing it into the seat back. For protection of all occupants in the cab, in the event of an accident, the inertial components within the clamp will constrain the SCBA bottle in the seat and will exceed the NFPA standard of 9 G.
There will be a quantity of
three (
3 )
SCBA brackets.
0603866
Seat Belt, Dual Retractor,
ReadyReach, Saber FR/Enforcer
SEAT BELTS
All cab and tiller cab (if applicable) seating positions will have red
seat belts. To provide quick,
easy use for occupants wearing bunker gear, the female buckle and seat belt webbing length will meet or exceed the current edition of NFPA
1901
and CAN/ULC - S
515
standards.
The
3 -point shoulder type seat belts will include height adjustment. This adjustment will optimize the belts effectiveness and comfort for the seated firefighter. The 3 -point shoulder type seat belts
will be furnished with dual automatic retractors that will provide ease of operation in the normal seating position.
The
3 -point shoulder type belts will also include the ReadyReach D-loop assembly to the shoulder belt system. The ReadyReach feature adds an extender arm to the D-loop location placing the D-loop in a closer, easier to reach location.
Any flip up seats will include a
3 -point shoulder type belts only.
To ensure safe operation, the seats will be equipped with seat belt sensors in the seat cushion and belt receptacle that will activate an alarm indicating a seat is occupied but not buckled. 0543133
Bracket, Helmet Holder, Zico UHH-1
HELMET HOLDER
There will be a total of
four (
4 )
Zico, Model UHH-
1 , helmet holder bracket(s) provided in the cab.
The brackets will provide secure storage and quick access to each helmet. The location of the helmet holder bracket(s) will be determined at the time of final inspection. 0647638
Lights, Dome, Weldon Dual LED 4
Lts
CAB DOME LIGHTS
There will be four (
4 ) Weldon
808
* series, dual LED dome lights with
grey
bezels provided. Two
(
2 ) lights will be mounted above the inside shoulder of the driver and officer and two ( 2 ) lights will
be installed and located, one (
1 ) on each side of the crew cab.
The color of the LED's will be
red and white
.
The white LED's will be controlled by
the door switches and the lens switch
.
The color LED's will be controlled by
the lens switch
.
0896451
Enhanced Software for Cab and
Crew Cab Dome Lts
ENHANCED SOFTWARE FOR CAB AND CREW CAB DOME LIGHTS
The cab and crew cab dome lights will remain on for
10 seconds for improved visibility after the
doors are closed.
The dome lights will dim after
10 seconds or immediately if the vehicle's transmission is put into gear.
0614669
Light, Map, Overhead, Round, Add,
Sunnex SL9-200B25L LED Clr Lens,
Ceiling Mount
ADDITIONAL MAP LIGHT
There will be
one (
1 )
Sunnex Model SL
9-200
B
25 L LED additional map light(s) installed in the cab
and located
Please match Job #
33716
. On the ceiling to serve the officers side
.
The light will be controlled by the switch on the base. The light switch(es) will be connected directly to the battery power
.
0628471
Light, Map, Overhead, Peterson
M371S LED, Rectangula w/Switch
ADDITIONAL OVERHEAD MAP LIGHT
There will be
one (
1 )
additional rectangular based adjustable map light(s) with white LEDs installed in the cab and located
TBD at pre-construction
.
Each light will include a switch on the light housing.
The light switch(es) will be connected
directly to the battery power
.
21 931
Bid #:
0727913
Spotlight, Golight/RadioRay, Model
20**4GT, LED, 2 Lts
CAB SPOTLIGHT
There will be two (
2 ) Golight, Model
20 **
4 GT,
white
LED spotlights located on the cab roof,
one
(
1 ) each side of the cab roof as far to the outside as possible . The spotlights will be mounted
on
visor brackets
.
These lights may be load managed when the parking brake is applied. 0650030
Controller, Spotlight, Golight, Wired
Dash Mount, 2 Lts
Spotlight Controller
There will be one (
1 ) wired dash mounted remote provided for each spotlight. 0649967
Location, Spotlight Controller, Driver
and Officer, 2 Lts
Spotlight Controller Locations
The remotes to control the spotlights will be located one ( 1 ) within reach of the driver and one (
1 )
within reach of the officer.
0544484
Handlts, (4) Streamlight, UltraStinger
w/AC/DC Charger
HAND HELD LIGHT
There will be four (
4 ) Streamlight, Model UltraStinger
™
lights provided. Each light will include an
AC/DC charger.
The flashlights will be mounted
Two (
2 ) each on the inboard side of each EMS cabinet
.
0554191
Handlight, Streamlight, Fire Vulcan,
44451, C4 LED, Tail Lights, 12v,
Orange
ADDITIONAL HAND HELD LIGHT
There will be
two (
2 ) lights
additional
12 v Streamlight, Model
#44451
, Fire Vulcan LED light(s) will
be provided and mounted
each side of the rear crew cab wall under the seat belt retractors . Each
light will be provided with a
12 volt direct wire vehicle mounting rack.
Each light housing will be orange in color and be provided with a single C 4 LED bulb and two (
2 )
"ultra bright blue tail-light LEDs". The tail-light LEDs will have a dual mode of blinking or steady. 0603606
Cab Instruments, Ivory Gauges,
Chrome Bezels, Enf MUX
CAB INSTRUMENTATION
The cab instrument panel will include gauges, an LCD display, telltale indicator lamps, control switches, alarms, and a diagnostic panel. The function of the instrument panel controls and switches will be identified by a label adjacent to each item. Actuation of the headlight switch will illuminate the labels in low light conditions. Telltale indicator lamps will not be illuminated unless necessary. The cab instruments and controls will be conveniently located within the forward cab section, forward of the driver. The gauge assembly and switch panels are designed to be removable for ease of service and low cost of ownership.
Gauges
The gauge panel will include the following ten (
10 ) ivory faced gauges with chrome bezels to
monitor vehicle performance:
Voltmeter gauge (volts):
Low volts (
11.8 VDC)
Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
High volts (
15.5 VDC)
Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Very low volts (
11.3 VDC)
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Very high volts (
16.0 VDC)
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Engine Tachometer (RPM)
Speedometer MPH (Major Scale), KM/H (Minor Scale)
Fuel level gauge (Empty - Full in fractions):
Low fuel (
1/8
full)
Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Very low fuel (
1/32
full)
Red caution indicator on the information center with steady alarm Amber caution light on gauge assembly
Engine Oil pressure Gauge (PSI):
Low oil pressure to activate engine warning lights and alarms Red caution indicator on the information center with steady alarm Amber caution light on gauge assembly
Front Air Pressure Gauges (PSI):
Low air pressure to activate warning lights and alarm
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Rear Air Pressure Gauges (PSI):
Low air pressure to activate warning lights and alarm
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Transmission Oil Temperature Gauge (Fahrenheit):
High transmission oil temperature activates warning lights and alarm Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Engine Coolant Temperature Gauge (Fahrenheit):
High engine temperature activates an engine warning light and alarms Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Diesel Exhaust Fluid Level Gauge (Empty - Full in fractions):
Low fluid (
1/8
full)
22 931
Bid #:
Amber indicator light in gauge dial
All gauges will perform prove out at initial power-up to ensure proper performance.
Indicator Lamps
To promote safety, the following telltale indicator lamps will be located on the instrument panel in clear view of the driver. The indicator lamps will be "dead-front" design that is only visible when active. The colored indicator lights will have descriptive text or symbols.
The following amber telltale lamps will be present:
Low coolant
Trac cntl (traction control) (where applicable
Check engine
Check trans (check transmission
Aux brake overheat (Auxiliary brake overheat
Air rest (air restriction)
Caution (triangle symbol)
Water in fuel
DPF (engine diesel particulate filter regeneration)
Trailer ABS (where applicable)
Wait to start (where applicable)
HET (engine high exhaust temperature) (where applicable) ABS (antilock brake system)
MIL (engine emissions system malfunction indicator lamp) (where applicable) Side roll fault (where applicable)
Front air bag fault (where applicable)
The following red telltale lamps will be present:
Warning (stop sign symbol)
Seat belt
Parking brake
Stop engine
Rack down
The following green telltale lamps will be provided:
Left turn
Right turn
Battery on
The following blue telltale lamp will be provided:
High beam
Alarms
Audible steady tone warning alarm: A steady audible tone alarm will be provided whenever a warning message is present.
Audible pulsing tone caution alarm: A pulsing audible tone alarm (chime/chirp) will be provided whenever a caution message is present without a warning message being present.
Alarm silence: Any active audible alarm will be able to be silenced by holding the ignition switch at the top position for three (
3 ) to five (
5 ) seconds. For improved safety, silenced audible alarms will intermittently chirp every
30 seconds until the alarm condition no longer exists. The intermittent chirp will act as a reminder to the operator that a caution or warning condition still exists. Any new warning or caution condition will enable the steady or pulsing tones respectively.
Indicator Lamp and Alarm Prove-Out
A system will be provided which automatically tests telltale indicator lights and alarms located on the cab instrument panel. Telltale indicators and alarms will perform prove-out at initial power-up to ensure proper performance.
Control Switches
For ease of use, the following controls will be provided immediately adjacent to the cab instrument panel within easy reach of the driver. All switches will have backlit labels for low light applications.
Headlight/Parking light switch: A three (
3 )-position maintained rocker switch will be
provided. The first switch position will deactivate all parking and headlights. The second switch position will activate the parking lights. The third switch will activate the headlights.
Panel back lighting intensity control switch: A three ( 3 )-position momentary rocker switch
will be provided. Pressing the top half of the switch, "Panel Up" increases the panel back lighting intensity and pressing the bottom half of the switch, "Panel Down" decreases the panel back lighting intensity. Pressing the half or bottom half of the switch several times will allow back lighting intensity to be gradually varied from minimum to maximum intensity level for ease of use.
Ignition switch: A three (
3 )-position maintained/momentary rocker switch will be provided.
The first switch position will turn off and deactivate vehicle ignition. The second switch position will activate vehicle ignition and will perform prove-out on the telltale indicators and alarms for
3 to
5 seconds after the switch is turned on. A green indicator lamp is activated with vehicle ignition. The third momentary position will temporarily silence all active cab alarms. An alarm "chirp" may continue as long as alarm condition exists.
Switching ignition to off position will terminate the alarm silence feature and reset function of cab alarm system.
Engine start switch: A two (
2 )-position momentary rocker switch will be provided. The first switch position is the default switch position. The second switch position will activate the vehicle's engine. The switch actuator is designed to prevent accidental activation.
Hazard switch will be provided on the instrument panel or on the steering column.
Heater, defroster, and air conditioning control panel.
Windshield wiper control will include low, high and intermittent modes.
Turn signal arm: A self-canceling turn signal with high beam headlight will be provided.
Parking brake control: An air actuated push/pull park brake control valve will be provided.
Chassis horn control: Activation of the chassis horn control will be provided through the center of the steering wheel.
High idle engagement switch: A momentary rocker switch with integral indicator lamp will be provided. The switch will activate and deactivate the high idle function. The "OK To Engage High Idle" indicator lamp must be active for the high idle function to engage. A green indicator lamp integral to the high idle engagement switch will indicate when the high idle function is engaged.
"OK To Engage High Idle" indicator lamp: A green indicator light will be provided next to the high idle activation switch to indicate that the interlocks have been met to allow high 23 931
Bid #:
idle engagement.
Emergency switching will be controlled by
multiple individual warning light switches for
various groups or areas of emergency warning lights. An Emergency Master switch provided on the instrument panel that enables or disables all individual warning light switches is included
.
An additional "Emergency Master" button will be provided on the lower left hand corner of the gauge panel to allow convenient control of the "Emergency Master" system from inside the driver's door when standing on the ground.
Custom Switch Panels
The design of cab instrumentation will allow for emergency lighting and other switches to be placed within easy reach of the operator thus improving safety. There will be positions for up to four (
4 ) switch panels in the lower instrument console and up to six ( 6 ) switch
panels in the overhead visor console. All switches have backlit labels for low light conditions.
Diagnostic Panel
A diagnostic panel will be accessible while standing on the ground and located inside the driver's side door left of the steering column. The diagnostic panel will allow diagnostic tools such as computers to connect to various vehicle systems for improved troubleshooting providing a lower cost of ownership. Diagnostic switches will allow ABS systems to provide blink codes should a problem exist.
The diagnostic panel will include the following:
Engine diagnostic port
Transmission diagnostic port
ABS diagnostic port
Roll sensor diagnostic port
Command Zone USB diagnostic port
ABS diagnostic switch (blink codes flashed on ABS telltale indicator) Diesel particulate filter regeneration switch (where applicable) Diesel particulate filter regeneration inhibit switch (where applicable) Cab LCD Display
A digital four (
4 )-row by
20 -character dot matrix display will be integral to the gauge panel. The display will be capable of showing simple graphical images as well as text. The display will be split into three (
3 ) sections. Each section will have a
dedicated function. The upper left section will display the outside ambient temperature.
The upper right section will display the following, along with other configuration specific information:
Odometer
Trip mileage
PTO hours
Fuel consumption
Engine hours
The bottom section will display INFO, CAUTION, and WARNING messages. Text messages will automatically activate to describe the cause of an audible caution or warning alarm. The LCD will be capable of displaying multiple text messages should more than one caution or warning condition exist.
0509511
Air Restriction Indicator, Imp/Vel,
AXT, Dash CF, Enf MUX
AIR RESTRICTION INDICATOR
A high air restriction warning indicator light LCD message with amber warning indicator and audible alarm will be provided.
0543751
Light, Do Not Move Apparatus
"DO NOT MOVE APPARATUS" INDICATOR
A flashing red indicator light, located in the driving compartment, will be illuminated automatically per the current NFPA requirements. The light will be labeled "Do Not Move Apparatus If Light Is On."
The same circuit that activates the Do Not Move Apparatus indicator will activate a pulsing alarm
when the parking brake is released.
24 931
Bid #:
0509042
Messages, Open Dr/DNMT, Color
Dsply,
DO NOT MOVE TRUCK MESSAGES
Messages will be displayed on the Command Zone
™,
color display located within sight of the
driver whenever the Do Not Move Truck light is active. The messages will designate the item or items not in the stowed for vehicle travel position (parking brake disengaged).
The following messages will be displayed (where applicable):
Do Not Move Truck
DS Cab Door Open (Driver Side Cab Door Open)
PS Cab Door Open (Passenger's Side Cab Door Open)
DS Crew Cab Door Open (Driver Side Crew Cab Door Open)
PS Crew Cab Door Open (Passenger's Side Crew Cab Door Open) DS Body Door Open (Driver Side Body Door Open)
PS Body Door Open (Passenger's Side Body Door Open)
Rear Body Door Open
DS Ladder Rack Down (Driver Side Ladder Rack Down)
PS Ladder Rack Down (Passenger Side Ladder Rack Down)
Deck Gun Not Stowed
Lt Tower Not Stowed (Light Tower Not Stowed)
Fold Tank Not Stowed (Fold-A-Tank Not Stowed)
Aerial Not Stowed (Aerial Device Not Stowed)
Stabilizer Not Stowed
Steps Not Stowed
Handrail Not Stowed
Any other device that is opened, extended, or deployed that creates a hazard or is likely to cause major damage to the apparatus if the apparatus is moved will be displayed as a caution message after the parking brake is disengaged.
0611683
Switching, Cab Instrument Lower
Console & Overhead, Membrane,
Enforcer WiFi MUX
SWITCH PANELS
The emergency light switch panel will have a master switch for ease of use plus individual switches for selective control. Each switch panel will contain eight ( 8 ) membrane-type switches
each rated for one million (
1,000,000
) cycles. Panels containing less than eight (
8 ) switch
assignments will include non-functioning black appliqués. The built-in switch panels will be located in the lower console or overhead console of the cab.
Additional switch panel(s) will be located in the overhead position(s) above the windshield or in designated locations on the lower instrument panel layout.
The switches will be membrane-type and also act as an integral indicator light. For quick, visual indication the entire surface of the switch will be illuminated white whenever back lighting is activated and illuminated green whenever the switch is active. An active illuminated switch will flash when interlock requirements are not met or device is actively being load managed. For ease of use, a two (
2 )-ply, scratch resistant laser engraved Gravoply label indicating the use of each switch will be placed in the center of the switch. The label will allow light to pass through the letters for ease of use in low light conditions.
0802946
Wiper Control, 2-Speed
w/Intermittent, Steering Wheel, Left
Pod, SFR/Enf
WIPER CONTROL
Wiper control will consist of a two (
2 )-speed windshield wiper control with intermittent feature and windshield washer controls. The control will be located in the left hand pod of the steering wheel. 0547505
Wiring, Spare, 10 A 12V DC 1st
SPARE CIRCUIT
There will be
two (
2 )
pair of wires, including a positive and a negative, installed on the apparatus.
The above wires will have the following features:
The positive wire will be connected
directly to the battery switched power
.
The negative wire will be connected to ground.
Wires will be protected to
10 amps at
12 volts DC.
Power and ground will terminate
one to the DS cab door lower angled wire way and
1 to the PS
on the side of the froward engine tunnel as marked with blue tape. .
Termination will be
with heat shrinkable butt splicing
.
Wires will be sized to
125
percent of the protection.
This circuit(s) may be load managed when the parking brake is applied. 0548004
Wiring, Spare, 15 A 12V DC 1st
SPARE CIRCUIT
There will be
two (
2 )
pair of wires, including a positive and a negative, installed on the apparatus.
The above wires will have the following features:
The positive wire will be connected
directly to the battery power
The negative wire will be connected to ground
Wires will be protected to
15 amps at
12 volts DC
Power and ground will terminate
behind officer seat
Termination will be
with heat shrinkable butt splicing
Wires will be sized to
125
percent of the protection
The circuit(s) may be load managed when the parking brake is set. 25 931
Bid #:
0548006
Wiring, Spare, 15 A 12V DC 2nd
SPARE CIRCUIT
There will be
six (
6 )
pair of wires, including a positive and a negative, installed on the apparatus.
The above wires will have the following features:
The positive wire will be connected
directly to the battery power
.
The negative wire will be connected to ground.
Wires will be protected to
15 amps at
12 volts DC.
Power and ground will terminate
1 in each rear facing EMS mid height outboard
2 in the lower
switch assembly of the dash between the driver and officer positions (location #9
), and two (
2 ) in
compartment RS-
3 on the tank wall upper front and lower front corners. .
Termination will be
with
15 amp, power point plug with rubber cover
.
Wires will be sized to
125
percent of the protection.
This circuit(s) may be load managed when the parking brake is set. 0548009
Wiring, Spare, 20 A 12V DC 1st
SPARE CIRCUIT
There will be
one (
1 )
pair of wires, including a positive and a negative, installed on the apparatus.
The above wires will have the following features:
The positive wire will be connected
directly to the battery power
The negative wire will be connected to ground
Wires will be protected to
20 amps at
12 volts DC
Power and ground will terminate
recessed dash area in front of officer seat
Termination will be
with heat shrinkable butt splicing
Wires will be sized to
125%
of the protection
This circuit(s) may be load managed when the parking brake is set. 0803875
Radio, AM/FM/WB, Jensen, Frt,Rear
Aux In/Frt,Rear USB/Bluetooth
STEREO RADIO
A Jensen, heavy duty AM/FM / Bluetooth / Weatherband stereo radio, with front and rear auxiliary input will be installed
within reach of the officer
. There will be
5.25 " speakers installed
one (
1 ) pair
of
5.25 " speakers in the cab and one (
1 ) pair of
5.25 " speakers in the crew cab
. The antenna will
be
a side-mounted rubber antenna located on the right side of the cab .
The following features will be included:
-
180
watts max power output (
45 W x
4 )
- Bluetooth® streaming audio and controls
(A
2 DP/AVRCP) with hands-free calling (HFP)
- Electronic AM/FM tuner (US/Euro)
- iPod®/iPhone® ready via USB
- SiriusXM-Ready®
- Seven-channel NOAA weatherband with S.A.M.E. technology - USB
2.0 for playback of MP
3 & WMA audio files
- RBDS with PTY search
- Front and rear USB input
- Front and rear AUX input
0615386
Vehicle Information Center, 7" Color
Display, Touchscreen, MUX
INFORMATION CENTER
An information center employing a
7.00 " diagonal touch screen color LCD display will be encased in an ABS plastic housing.
The information center will have the following specifications:
Operate in temperatures from -
40 to
185
degrees Fahrenheit
An Optical Gel will be placed between the LCD and protective lens Five weather resistant user interface switches
Grey with black accents
Sunlight Readable
Linux operating system
Minimum of
1000
nits rated display
Display can be changed to an available foreign language A LCD display integral to the cab gauge panel will be included as outlined in the cab instrumentation area.
Programmed to read
US Customary
General Screen Design
Where possible, background colors will be used to provide "At a Glance" vehicle information. If information provided on a screen is within acceptable limits, a green background will be used.
If a caution or warning situation arises the following will occur:
An amber background/text color will indicate a caution condition A red background/text color will indicate a warning condition The information center will utilize an "Alert Center" to display text messages for audible alarm tones. The text messages will be written to identify the item(s) causing the audible alarm to sound. If more than one (
1 ) text message occurs, the messages will cycle every second until the problem(s) have been resolved. The background color for the "Alert Center" will change to indicate the severity of the "warning" message. If a warning and a caution condition occur simultaneously, the red background color will be shown for all alert center messages.
A label for each button will exist. The label will indicate the function for each active button for each screen. Buttons that are not utilized on specific screens will have a button label with no text or symbol.
Home/Transit Screen
This screen will display the following:
Vehicle Mitigation (if equipped)
Water Level (if the water level system includes compatible communications to the information center)
Foam Level (if the foam level system includes compatible communications to the information center)
Seat Belt Monitoring Screen Seat Belt Monitoring Screen Tire Pressure Monitoring (if equipped)
Digital Speedometer
Active Alarms
26 931
Bid #:
On Scene Screen
This screen will display the following and will be auto activated with pump engaged (if equipped):
Battery Voltage
Fuel
Oil Pressure
Coolant Temperature
RPM
Water Level (if equipped)
Foam Level (if equipped)
Foam Concentration (if equipped)
Water Flow Rate (if equipped)
Water Used (if equipped)
Active Alarms
Virtual Buttons
There will be four (
4 ) virtual switch panel screens that match the overhead and lower lighting and HVAC switch panels.
Page Screen
The page screen will display the following and allow the user to progress into other screens for further functionality:
Diagnostics
Faults
Listed by order of occurrence
Allows to sort by system
Interlock
Throttle Interlocks
Pump Interlocks (if equipped)
Aerial Interlocks (if equipped)
PTO Interlocks (if equipped)
Load Manager
A list of items to be load managed will be provided. The list will provide a description of the load.
The lower the priority numbers the earlier the device will be shed should a low voltage condition occur.
The screen will indicate if a load has been shed (disabled) or not shed. "At a glance" color features are utilized on this screen.
Systems
Command Zone
Module type and ID number
Module Version
Input or output number
Circuit number connected to that input or output
Status of the input or output
Power and Constant Current module diagnostic information Foam (if equipped)
Pressure Controller (if equipped)
Generator Frequency (if equipped)
Live Data
General Truck Data
Maintenance
Engine oil and filter
Transmission oil and filter
Pump oil (if equipped)
Foam (if equipped)
Aerial (if equipped)
Setup
Clock Setup
Date & Time
12 or
24 hour format
Set time and date
Backlight
Daytime
Night time
Sensitivity
Unit Selection
Home Screen
Virtual Button Setup
On Scene Screen Setup
Configure Video Mode
Set Video Contrast
Set Video Color
Set Video Tint
Do Not Move
The screen will indicate the approximate location and type of item that is open or is not stowed for travel. The actual status of the following devices will be indicated Driver Side Cab Door
Passenger's Side Cab Door
Driver Side Crew Cab Door
Passenger's Side Crew Cab Door
Driver Side Body Doors
Passenger's Side Body Doors
Rear Body Door(s)
Ladder Rack (if applicable)
Deck Gun (if applicable)
Light Tower (if applicable)
Hatch Door (if applicable)
Stabilizers (if applicable)
Steps (if applicable)
Notifications
View Active Alarms
27 931
Bid #:
Shows a list of all active alarms including date and time of the occurrence is shown with each alarm
Silence Alarms - All alarms are silenced
Timer Screen
HVAC (if equipped)
Tire Information (if equipped)
Ascendant Set Up Confirmation (if equipped)
Button functions and button labels may change with each screen. 0734857
Collision Mitigation, HAAS Alert
(R2V), HA5
COLLISION MITIGATION
There will be a HAAS Alert®, Model HA
5 Responder-to-Vehicle (R
2 V) collision avoidance system
provided on the apparatus. The HA
5 cellular transponder module will be installed behind the cab windshield, as high and near to the center as practical, to allow clear visibility to the sky. The module dimensions are
5.40 " long x
2.70 " wide x
1.30 " high, and operating temperature range is
-
40 degree C to
85 degree C.
The transponder will be connected to the vehicle's emergency master circuit and battery direct power and ground.
While responding with emergency lights on, the HA
5 transponder sends alert messages via
cellular network to motorists in the vicinity of the responding truck that are equipped with the WAZE app.
While on scene with emergency lights on, the HA
5 transponder sends road hazard alerts to
motorists in the vicinity of the truck that are equipped with the WAZE app.
The HA
5 Responder-to-Vehicle (R
2 V) collision avoidance system will include
the transponder
and a
5 year cellular plan subscription
.
Activation of the HAAS Alert system requires a representative of the customer to accept the End User License Agreement (EULA) via an on-line portal.
0606247
Vehicle Data Recorder w/CZ Display
Seat Belt Monitor
VEHICLE DATA RECORDER
There will be a vehicle data recorder (VDR) capable of reading and storing vehicle information provided.
The information stored on the VDR can be downloaded through a USB port mounted in a convenient location determined by cab model. A USB cable can be used to connect the VDR to a laptop to retrieve required information. The program to download the information from the VDR will be available to download on-line.
The vehicle data recorder will be capable of recording the following data via hardwired and/or CAN inputs:
Vehicle Speed - MPH
Acceleration - MPH/sec
Deceleration - MPH/sec
Engine Speed - RPM
Engine Throttle Position - % of Full Throttle
ABS Event - On/Off
Seat Occupied Status - Yes/No by Position
Seat Belt Buckled Status - Yes/No by Position
Master Optical Warning Device Switch - On/Off
Time -
24 Hour Time
Date - Year/Month/Day
Seat Belt Monitoring System
A seat belt monitoring system (SBMS) will be provided on the Command Zone ™
color display.
The SBMS will be capable of monitoring up to
10 seating positions indicating the status of each
seat position per the following:
Seat Occupied & Buckled = Green LED indicator illuminated Seat Occupied & Unbuckled = Red LED indicator with audible alarm No Occupant & Buckled = Red LED indicator with audible alarm No Occupant & Unbuckled = No indicator and no alarm
The seat belt monitoring screen will become active on the Command Zone color display when:
The home screen is active:
and there is any occupant seated but not buckled or any belt buckled with an occupant. and there are no other Do Not Move Apparatus conditions present. As soon as all Do Not Move Apparatus conditions are cleared, the SBMS will be activated.
The SBMS will include an audible alarm that will warn that an unbuckled occupant condition exists and the parking brake is released, or the transmission is not in park. 0606226
Signal, Recordable, VDR, Silence
Alarm, AXT MUX, DCF, SFR/Enf,
Imp/Vel, Qtm
Vehicle Data Recordable Input
When the VDR is active, the seat belt monitoring system alarm will be silenced through the standard silence alarm switch. The alarm will chirp in intervals to remind the operator that an alarm is still sounding.
28 931
Bid #:
0663247
Intercom, Firecom 5100D Single
Radio, 4-Pos, D,O,2C
INTERCOM SYSTEM
There will be digital, single radio interface, intercom located
PER APPROVED IP LAYOUT
Change to intercom on the EMS cabinet on the back wall behind the officers seat. Match Job 33716
in the cab. The front panel will have master volume, and squelch controls with illuminated indicators, allowing for independent level setting of radio and auxiliary audio devices.
There will be one (
1 ) radio listen only / transmit control with select, monitor, receive, and transmit indicators. There will be one (
1 ) auxiliary audio input with select, and receive indicators.
Headset jacks will be provided for the driver, officer, and two ( 2 ) crew positions located
at both
forward facing seats
.
The following Firecom components will be provided:
One (
1 )
5100
D Intercom
Four (
4 ) HM-
10 Interior headset jacks
All necessary power and station cabling
0006240
Cable, Radio to Intercom Interface,
Firecom, 1 Radio
RADIO / INTERCOM INTERFACE CABLE
The apparatus manufacturer will supply and install one ( 1 ) radio interface cable before delivery of
the vehicle.
The radio equipment to be used by the customer will be:
Kenwood
, Model number
NX-
5000
.
0681393
Headset, Firecom, FH-54 Over Head,
Intercom Only, Mic On/Off
OVER THE HEAD HEADSET, INTERCOM ONLY
There will be
two (
2 )
Firecom, Model FH-
54 over the head, intercom only headset(s) provided
driver's side inboard forward facing seat and passenger's side inboard forward facing seat .
Each headset will feature:
Coiled cord with rugged angled plug
Noise cancelling electric microphone
Flex boom rotates for left or right dress
Adjustable volume control
ComLeather ear seals with
24 dB noise reduction
Microphone on/off button
0681413
Headset, Firecom, FH-51 Over Head,
Radio Transmit
OVER THE HEAD, RADIO TRANSMIT HEADSET
There will be
two (
2 )
over the head, radio transmit headset(s) provided
driver's seat and officer
seat
.
Each Firecom, Model FH-
51 headset will feature:
Coiled cord with rugged angled plug
Noise cancelling electric microphone
Flex boom rotates for left or right dress
Adjustable volume control
ComLeather ear seals with
24 dB noise reduction
Radio Push To Transmit button. Mic is always live for intercom communication 0681408
Hangers For Headsets, NFPA, Each
HEADSET HANGERS
There will be
four (
4 )
headset hanger(s) installed
driver's seat, officer's seat, driver's side
outboard forward facing seat and passenger's side outboard forward facing seat . The hanger(s)
will meet NFPA
1901
, Section
14.1.11 , requirement for equipment mounting.
0663968
Install Customer Provided Drug Vault,
Knox Model #2 With WiFi, in Cab
KNOX-BOX®
There will be
one (
1 )
Knox-Box MedVault
2 , surface mount with Ethernet cable will be sent to the apparatus manufacturers preferred installer and installed in the on top of the EMS compartment
on the passenger side and facing to the rear
.
A "technician's key" will be provided by the customer for each Knox Box. The box cannot be installed without a compatible technician's key.
Specific shipping requirements will be followed.
0640003
Install Customer Provided Modem
MOBILE RADIO MODEM INSTALLATION
There will be
one (
1 )
customer supplied modem(s) sent to the apparatus manufacturers preferred installer to be installed
behind the officer seat on the back wall of the passenger side EMS compartment
.
Specific shipping requirements will be followed.
0616382
Install Customer Provided
GPS/Multimode Antenna(s)
GPS / MULTIMODE ANTENNA INSTALLATION
There will be
one (
1 )
customer supplied GPS / Multimode antenna(s) with stud mount for thick roof material to be installed on the roof. The antenna coax cable(s) will be run per the packing list / instructions provided to the third party installer.
Specific shipping requirements will be followed. The GPS / Multimode antenna will be sent to the apparatus manufacturers preferred installer prior to cab fabrication. 0559156
Install Customer Provided Two-Way
Radio(s)
TWO WAY RADIO INSTALLATION
There will be
one (
1 )
customer supplied two way radio(s) sent to the apparatus manufacturers preferred radio installer to be installed
per approved layout matching job
33716
per the shipping
document.
No antenna mount or whip will be included in this option.
Specific radio shipping requirements will be followed.
29 931
Bid #:
0559503
Install Customer Provided, Portable
Radio Charger(s)
PORTABLE RADIO CHARGER INSTALLATION
There will be
two (
2 )
customer supplied portable two-way radio chargers(s) sent to the apparatus manufacturers preferred radio installer to be installed on the front surface of the mapbox
matching job
33716
. Specific shipping requirements will be followed.
0687904
Antenna Mount, Custom Chassis,
Cable Routed to Behind Officer Seat
RADIO ANTENNA MOUNT
There will be
two (
2 )
standard
1.125
",
18 thread antenna-mounting base(s) installed
driver side
and center
on the cab roof with high efficiency, low loss, coaxial cable(s) routed to behind the officer seat. A weatherproof cap will be installed on the mount. 0653526
Camera, Pierce, LS Mux, R, Camera
VEHICLE CAMERA SYSTEM
There will be a color vehicle camera system provided with the following:
One (
1 ) camera located at the rear of the apparatus, pointing rearward, displayed automatically with the vehicle in reverse
The camera images will be displayed on the left side vehicle information center display. Audio from the microphone on the active camera will be
emitted by an amplified speaker with volume
control located on the instrument panel
.
The following components will be included:
One (
1 ) SV-CW
134639
CAI, camera
One (
1 ) amplified speaker (if applicable)
All necessary cables
0814831
Not Required, Camera Switcher
CAMERA SWITCHER
A camera switcher is not required.
0511071
Guard, 4-Way, Rear Vision Camera
VEHICLE CAMERA GUARD
There will be
one (
1 )
aluminum treadplate guard(s) fastened over the vehicle camera(s) located camera to be mounted to the underside of the traffic advisor step with the guard also mounted to the underside so that it protects the underside of the camera. Match Job 33716
.
0890416
Pierce Command Zone, Advanced
Electronics & Control System,
Enforcer, WiFi CZT
ELECTRICAL POWER CONTROL SYSTEM
The primary power distribution will be located forward of the officer's seating position and be easily accessible while standing on the ground for simplified maintenance and troubleshooting.
Additional electrical distribution centers will be provided throughout the vehicle to house the vehicle's electrical power, circuit protection, and control components. The electrical distribution centers will be located strategically throughout the vehicle to minimize wire length. For ease of maintenance, all electrical distribution centers will be easily accessible. All distribution centers containing fuses, circuit breakers and/or relays will be easily accessible.
Distribution centers located throughout the vehicle will contain battery powered studs for supplying customer installed equipment thus providing a lower cost of ownership.
Circuit protection devices, which conform to SAE standards, will be utilized to protect electrical circuits. All circuit protection devices will be rated per NFPA requirements to prevent wire and component damage when subjected to extreme current overload. General protection circuit breakers will be Type-I automatic reset (continuously resetting). When required, automotive type fuses will be utilized to protect electronic equipment. Control relays and solenoid will have a direct current rating of
125
percent of the maximum current for which the circuit is protected per NFPA.
Solid-State Control System
A solid-state electronics based control system will be utilized to achieve advanced operation and control of the vehicle components. A fully computerized vehicle network will consist of electronic modules,
electronic control modules to include a see through housing, a power indicator, a status indicator and circuit indicators
located near their point of use to reduce harness lengths and improve reliability. The control system will comply with SAE J 1939-11
recommended practices.
The control system will operate as a master-slave system whereas the main control module instructs all other system components. The system will contain patented Mission Critical software that maintains critical vehicle operations in the unlikely event of a main controller error. The system will utilize a Real Time Operating System (RTOS) fully compliant with OSEK/VDX ™
specifications providing a lower cost of ownership.
For increased reliability and simplified use the control system modules will include the following attributes:
Green LED indicator light for module power
Red LED indicator light for network communication stability status Control system self test at activation and continually throughout vehicle operation No moving parts due to transistor logic
Software logic control for NFPA mandated safety interlocks and indicators Integrated electrical system load management without additional components Integrated electrical load sequencing system without additional components Customized control software to the vehicle's configuration Factory and field programmable to accommodate changes to the vehicle's operating parameters To assure long life and operation in a broad range of environmental conditions, the solid-state control system modules will meet the following specifications:
Module circuit board will meet SAE J
771
specifications
Operating temperature from -
40 C to +
70 C
Storage temperature from -
40 C to +
70 C
Vibration to
50 g
IP
67 rated enclosure (Totally protected against dust and also protected against the effect of temporary immersion between
15 centimeters and one (
1 ) meter)
Operating voltage from eight (
8 ) volts to
32 volts DC
The main controller will activate status indicators and audible alarms designed to provide warning of problems before they become critical.
30 931
Bid #:
Circuit Protection and Control Diagram
Copies of all job-specific, computer network input and output (I/O) connections will be provided with each chassis. The sheets will indicate the function of each module connection point, circuit protection information (where applicable), wire numbers, wire colors and load management information.
On-Board Electrical System Diagnostics
The on-board information center will include the following diagnostic information:
Text description of active warning or caution alarms
Simplified warning indicators
Amber caution indication with intermittent alarm
Red warning indication with steady tone alarm
Advanced diagnostic feature will be provided in this control system. From the Command Zone display or connected wireless device, these features allow the user to monitor the real-time status of every input or output on the vehicle. It also allows users logged in as an administrator to force on inputs or outputs to assist the troubleshooting process.
TCU Module with WiFi
An in cab module will provide WiFi wireless interface and data logging capability. The WiFi interface will comply with IEEE
802.11
b/g/n capabilities while communicating at
2.4 Gigahertz.
The module will communicate through a
black WiFi antenna
allowing a line of site communication
range of up to
300
feet with a roof mounted antenna.
The module will transmit a password protected web page to a WiFi enabled device (i.e. most smart phones, tablets or laptops) allowing two levels of user interaction. The firefighter level will allow vehicle monitoring of the vehicle and firefighting systems on the apparatus. The technician level will allow diagnostic access to inputs and outputs installed on the Command Zone ™,
control
and information system.
The TCU capability will record faults from the engine, transmission, ABS and Command Zone ™,
control and information systems as they occur. No other data will be recorded at the time the fault occurs. The data TCU will provide up to
2 Gigabytes of data storage.
The TCU will provide a means to download the TCU information and update software in the device.
Indicator Light and Alarm Prove-Out System
A system will be provided which automatically tests basic indicator lights and alarms located on the cab instrument panel.
Voltage Monitor System
A voltage monitoring system will be provided to indicate the status of the battery system connected to the vehicle's electrical load. The system will provide visual and audible warning when the system voltage is below or above optimum levels.
The alarm will activate if the system falls below
11.8 volts DC for more than two (
2 ) minutes.
Dedicated Radio Equipment Connection Points
There will be three (
3 ) studs provided in the primary power distribution center located in front of the officer for two-way radio equipment. The studs will consist of the following:
12 -volt
40 -amp battery switched power
12 -volt
60 -amp ignition switched power
12 -volt
60 -amp direct battery power
There will also be a
12 -volt
100
-amp ground stud located in or adjacent to the power distribution center.
EMI/RFI Protection
To prevent erroneous signals from crosstalk contamination and interference, the electrical system will meet, at a minimum, SAE J
551/2
, thus reducing undesired electromagnetic and radio
frequency emissions. An advanced electrical system will be used to ensure radiated and conducted electromagnetic interference (EMI) or radio frequency interference (RFI) emissions are suppressed at their source.
The apparatus will have the ability to operate in the electromagnetic environment typically found in fire ground operations to ensure clean operations. The electrical system will meet, without exceptions, electromagnetic susceptibility conforming to SAE J 1113/25
Region
1 , Class C EMR
for
10 KHz-
1 GHz to
100
Volts/Meter. The vehicle OEM, upon request, will provide EMC testing reports from testing conducted on an entire apparatus and will certify that the vehicle meets SAE J
551/2
and SAE J
1113/25
Region
1 , Class C EMR for
10 KHz-
1 GHz to
100
Volts/Meter
requirements. Component and partial (incomplete) vehicle testing is not adequate as overall vehicle design can impact test results and thus is not acceptable by itself.
EMI/RFI susceptibility will be controlled by applying appropriate circuit designs and shielding. The electrical system will be designed for full compatibility with low-level control signals and high- powered two-way radio communication systems. Harness and cable routing will be given careful attention to minimize the potential for conducting and radiated EMI/RFI susceptibility. 0896456
Prognostics, Electrical System
ELECTRICAL SYSTEM PROGNOSTICS
There will be a software based vehicle tool provided to predict remaining life of the vehicles critical fluid and events.
The system will send automatic indications to the Command Zone ™
information center and/or
wireless enabled devices to proactively alert of upcoming service intervals.
Prognostics will include the following:
Engine oil and filter
Transmission oil and filter
31 931
Bid #:
0624253
Electrical System, Enforcer MUX
ELECTRICAL
All
12 -volt electrical equipment installed by the apparatus manufacturer will conform to modern automotive practices. All wiring will be high temperature crosslink type. Wiring will be run, in loom or conduit, where exposed and have grommets where wire passes through sheet metal.
Automatic reset circuit breakers will be provided which conform to SAE Standards. Wiring will be color, function and number coded. Function and number codes will be continuously imprinted on all wiring harness conductors at
2.00 " intervals. Exterior exposed wire connectors will be positive locking, and environmentally sealed to withstand elements such as temperature extremes, moisture and automotive fluids.
Electrical wiring and equipment will be installed utilizing the following guidelines:
All holes made in the roof will be caulked with silicon. Large fender washers, liberally caulked, will be used when fastening equipment to the underside of the cab roof.
Any electrical component that is installed in an exposed area will be mounted in a manner that will not allow moisture to accumulate in it. Exposed area will be defined as any location outside of the cab or body.
Electrical components designed to be removed for maintenance will not be fastened with nuts and bolts. Metal screws will be used in mounting these devices. Also a coil of wire will be provided behind the appliance to allow them to be pulled away from mounting area for inspection and service work.
Corrosion preventative compound will be applied to all terminal plugs located outside of the cab or body. All non-waterproof connections will require this compound in the plug to prevent corrosion and for easy separation (of the plug).
All lights that have their sockets in a weather exposed area will have corrosion preventative compound added to the socket terminal area.
All electrical terminals in exposed areas will have silicon applied completely over the metal portion of the terminal.
All lights and reflectors, required to comply with Federal Motor Vehicle Safety Standard #108
, will
be furnished. Rear identification lights will be recessed mounted for protection. Lights and wiring mounted in the rear bulkheads will be protected from damage by installing a false bulkhead inside the rear compartments.
An operational test will be conducted to ensure that any equipment that is permanently attached to the electrical system is properly connected and in working order.
The results of the tests will be recorded and provided to the purchaser at time of delivery. 0079212
Batteries, (6) Stryten/Exide Grp 31,
950 CCA each, SAE Posts
BATTERY SYSTEM
Six (
6 )
12 volt, Stryten/Exide, Model
31 A
950
X
1 W, group
31 batteries that include the following
features will be provided:
950
CCA, cold cranking amps
190
amp reserve capacity
High cycle
Rating of
5700
CCA at
0 degrees Fahrenheit
1140
minutes of reserve capacity
SAE Posts
Each battery case will be a black polypropylene material with a vertically ribbed container for increased vibration resistance. The cover will be manifold vented with a central venting location to allow a
45 degree tilt capacity.
The inside of each battery will consist of a "maintenance free" grid construction with poly wrapped separators and a flooded epoxy bottom anchoring for maximum vibration resistance. 0008621
Battery System, Single Start, All
Custom Chassis
BATTERY SYSTEM
There will be a single starting system with an ignition switch and starter button provided and located on the cab instrument panel.
MASTER BATTERY SWITCH
There will be a master battery switch provided within the cab within easy reach of the driver to activate the battery system.
An indicator light will be provided on the instrument panel to notify the driver of the status of the battery system.
0002698
Battery Compartment,
Saber/Enforcer
BATTERY COMPARTMENTS
Batteries will be placed on non-corrosive mats and be stored in well ventilated compartments located under the cab and bolted directly to the chassis frame. The battery boxes will have reinforced sides. The battery compartments will be constructed of
0.188
" steel plate and be
designed to accommodate a maximum of three (
3 ) group
31 batteries in each compartment. The
battery hold-downs will be of a non-corrosive material. All bolts and nuts will be stainless steel.
Heavy-duty,
2/0
gauge, color coded battery cables will be provided. Battery terminal connections will be coated with anti-corrosion compound.
Battery solenoid terminal connections will be encapsulated with semi-permanent rubberized compound.
JUMPER STUDS
One (
1 ) set of battery jumper studs with plastic color-coded covers will be included on the battery compartments.
0803511
Not Required - Battery Charger
Included In Inverter/Charger Category
0814995
Not Required, Location Picked From
Location,Inverter/Battery
Charger/Conditioner
32 931
Bid #:
0814764
SP
Inverter/Bat Charger, Xantrex
Freedom 817-2080, GFCI, Non-
NFPA
INVERTER / BATTERY CHARGER
There will be a Xantrex part number
817-2080
, inverter/battery charger provided. The inverter to
include the following:
GFCI duplex receptacle
The inverter will be connected to the batteries through proper fusing and also to shoreline AC power.
An auto transfer switch will be included allowing AC loads connected to the inverter to be powered from the battery whenever shoreline AC power is not available, and the main chassis battery switch is on. If shoreline AC power is available, the battery charger function will be active and the AC loads connected.
Per NFPA
1901
,
2016
Edition
22.5.5.2 *
The alternator and/or battery system will be adequate to provide power for continuous operation for a minimum of
2 hours at full output.
Per the fire department specifications, the alternator may not provide adequate power for continuous operation for
2 hours and a certification is therefore invalid. The apparatus will be non compliant to NFPA
1901
standards at time of contract execution.
Load management will be activated in low voltage situations, and the inverter will be de- energized until chassis electrical system voltage recovers. 0814986
Location, Body, Inverter/Battery
Charger, Forward Compartment, RS
The battery charger/inverter will be located in the right side forward body compartment located on
the back wall as high as practical
.
0812411
SP
Display, Kussmaul Single Bat Status
Ind 091-94-12, Wired to Batteries
BATTERY CHARGE DISPLAY
There will be one (
1 ) Kussmaul
™,
Model
091-94-12
, universal single battery bank bar graph
display provided.
The display will read voltage direct from the battery system. 0814946
Location, Cab, Ind/Remote Display,
Above Wheelwell, LS
The battery charger/Inverter status indication/display(s) will be located above the cab left side wheel well.
0812004
SP
Approved, Inverter/Batt Chgr
0016857
Shoreline, 20A 120V, Kussmaul Auto
Eject, 091-55-20-120, Super
AUTO EJECT FOR SHORELINE
There will be
one (
1 )
Kussmaul
™,
Model
091-55-20-120
,
20 amp
120
volt AC shoreline inlet(s)
provided to operate the dedicated
120
volt AC circuits on the apparatus.
The shoreline inlet(s) will include
red
weatherproof flip up cover(s).
There will be a release solenoid wired to the vehicle's starter to eject the AC connector when the engine is starting.
The shoreline(s) will be connected to
the battery charger
.
There will be a mating connector body supplied with the loose equipment.
There will be a label installed near the inlet(s) that state the following:
Line Voltage
Current Ratting (amps)
Phase
Frequency
0026800
Shoreline Location
The shoreline receptacle will be located
on the driver side of cab, above wheel
.
0647728
Alternator, 430 amp, Delco Remy
55SI
ALTERNATOR
A Delco Remy
®
, Model
55 SI, alternator will be provided. It will have a rated output current of 430
amps, as measured by SAE method J
56 . The alternator will feature an integral regulator and rectifier system that has been tested and qualified to an ambient temperature of 257
degrees
Fahrenheit (
125
degrees Celsius). The alternator will be connected to the power and ground distribution system with heavy-duty cables sized to carry the full rated alternator output. 0686615
Set Command Zone Clock To Pacific
Standard Time
0550970
Fan, 12v, Electrical Component
Cooling
ELECTRICAL COOLING FAN
There will be
one (
1 )
12 v electrical cooling fan to be located
compartment LS-
3 to serve the
inverter/charger on the right wall up high mount just above the louvers. . The fan will vent the heat
outward.
Fan to be wired to the battery switch.
33 931
Bid #:
0092582
Load Manager/Sequencer, MUX
ELECTRONIC LOAD MANAGER
An electronic load management (ELM) system will be provided that monitors the vehicles 12 -volt
electrical system, automatically reducing the electrical load in the event of a low voltage condition, and automatically restoring the shed electrical loads when a low voltage condition expires. This ensures the integrity of the electrical system.
For improved reliability and ease of use, the load manager system will be an integral part of the vehicle's solid state control system requiring no additional components to perform load management tasks. Load management systems which require additional components will not be allowed.
The system will include the following features:
System voltage monitoring.
A shed load will remain inactive for a minimum of five minutes to prevent the load from cycling on and off.
Sixteen available electronic load shedding levels.
Priority levels can be set for individual outputs.
High Idle
to activate before any electric loads are shed and deactivate with the service brake .
If enabled:
"Load Man Hi-Idle On" will display on the information center.
Hi-Idle will not activate until
30 seconds after engine start up.
Individual switch "on" indicator to flash when the particular load has been shed.
The information center indicates system voltage.
The information center, where applicable, includes a "Load Manager" screen indicating the following:
Load managed items list, with priority levels and item condition.
Individual load managed item condition:
ON = not shed
SHED = shed
SEQUENCER
A sequencer will be provided that automatically activates and deactivates vehicle loads in a preset sequence thereby protecting the alternator from power surges. This sequencer operation will allow a gradual increase or decrease in alternator output, rather than loading or dumping the entire
12 volt load to prolong the life of the alternator.
For improved reliability and ease of use, the load sequencing system will be an integral part of the vehicle's solid state control system requiring no additional components to perform load sequencing tasks. Load sequencing systems which require additional components will not be allowed.
Emergency light sequencing will operate in conjunction with the emergency master light switch.
When the emergency master switch is activated, the emergency lights will be activated one by one at half-second intervals. Sequenced emergency light switch indicators will flash while waiting for activation.
When the emergency master switch is deactivated, the sequencer will deactivate the warning light loads in the reverse order.
Sequencing of the following items will also occur, in conjunction with the ignition switch, at half- second intervals:
Cab Heater and Air Conditioning
Crew Cab Heater (if applicable)
Crew Cab Air Conditioning (if applicable)
Exhaust Fans (if applicable)
Third Evaporator (if applicable)
0783153
Headlights, Rect LED, JW Spkr Evo
2, AXT/DCF/Enf/Imp/Sab/Vel
HEADLIGHTS
There will be four (
4 ) JW Speaker®, Model
8800
,
4 " x
6 " rectangular LED lights mounted in the
front quad style, chrome housing on each side of the cab grille:
the outside light on each side will contain a part number 055
***
1 low beam module
the inside light on each side will contain a part number 055
***
1 high beam module
the
headlights to include chrome bezels
The low beam lights will be activated when the headlight switch is on.
The high beam and low beam lights will be activated when the headlight switch and the high beam switch is activated.
0804646
Light, Directional, Wln M62T* LED,
Below Headlights, Sab/Enf
FRONT DIRECTIONALS
The front directional lights will be Whelen®, Model M
62 T*,
4.31 " high x
6.75 " wide x
1.37 " deep
directional lights with amber LEDs. The
lens color(s) to be the same as the LEDs
. The directional
lights will be provided with
chrome trim
and located below the headlights.
The flash pattern of the directional lights will be
Steady On (Arrow)
.
0620054
Light, Directional/Marker,
Intermediate, Weldon 9186-8580-29
LED 2lts
INTERMEDIATE LIGHT
There will be two (
2 ) Weldon, Model
9186-8580-29
, amber LED turn signal marker lights
furnished, one (
1 ) each side, in the rear fender panel. The light will double as a turn signal and marker light.
0735474
Lights, Clearance/Marker/ID, Front,
P25 LED 7 Lts, Saber FR/Enforcer
CAB CLEARANCE/MARKER/ID LIGHTS
There will be seven (
7 ) amber LED lights provided per the following:
Three (
3 ) amber LED identification lights will be installed in the center of the cab above the windshield.
Two (
2 ) amber LED clearance lights will be installed, one ( 1 ) on each outboard side of the cab
above the windshield as close to the outside of the apparatus as practical.
Two (
2 ) amber LED clearance lights will be installed, one ( 1 ) on each side of the cab as high and
far forward as practical.
The lights will be installed
without guards
.
34 931
Bid #:
0647899
Lights, Directional/Marker, Cab Front
Side, Weldon 9186-8580-29 LED,
Sab/Enf
FRONT CAB SIDE DIRECTIONAL/MARKER LIGHTS
There will be two (
2 ) Weldon, Model
9186-8580-29
, amber LED lights installed front of the cab
door, one (
1 ) on each side of the cab.
The lights will activate as marker lights with the headlight switch and directional lights with the corresponding directional circuit.
0627282
Lights, Clearance/Marker/ID, Rear,
FRP LED Bar & P25 LED 4Lts
REAR CLEARANCE/MARKER/ID LIGHTING
There will be a three (
3 ) LED light bar used as identification lights located at the rear of the apparatus per the following:
As close as practical to the vertical centerline
Centers spaced not less than
6.00 " or more than
12.00 " apart
Red in color
All at the same height
There will be two (
2 ) LED lights installed at the rear of the apparatus used as clearance lights located at the rear of the apparatus per the following:
To indicate the overall width of the vehicle
One (
1 ) each side of the vertical centerline
As near the top as practical
Red in color
To be visible from the rear
All at the same height
There will be two (
2 ) LED lights installed on the side of the apparatus used as marker lights as close to the rear as practical per the following:
To indicate the overall length of the vehicle
One (
1 ) each side of the vertical centerline
As near the top as practical
Red in color
To be visible from the side
All at the same height
There will be two (
2 ) red reflectors located on the rear of the truck facing to the rear. One ( 1 ) each
side, as far to the outside as practical, at a minimum of
15.00 ", but no more than
60.00 ", above
the ground.
There will be two (
2 ) red reflectors located on the side of the truck facing to the side. One ( 1 )
each side, as far to the rear as practical, at a minimum of
15.00 ", but no more than
60.00 ", above
the ground.
Per FMVSS
108
and CMVSS
108
requirements.
0804514
Lights, Tail, Wln M62BTT* Red
Stop/Tail & M62T* Amber Dir Arw For
Hsg
REAR FMVSS LIGHTING
The rear stop/tail and directional lighting included in the rear tail light housing will include the following:
Two (
2 ) Whelen®, Model M
62 BTT,
4.30 " high x
6.70 " wide x
1.40 " deep brake/tail lights with red
LEDs
Two (
2 ) Whelen, Model M
62 T,
4.30 " high x
6.70 " wide x
1.40 " deep directional lights with amber
LEDs. The directional lights will be set to
Steady On (Arrow)
flash pattern.
The
lens color(s) to be the same as the LEDs
.
0806466
Lights, Backup, Wln M62BU, LED,
For Tail Lt Housing
There will be two (2) Whelen Model M62BU, LED backup lights provided in the tail light housing. 0889577
Bracket, License Plate & Light, P25
LED, Stainless Brkt
LICENSE PLATE BRACKET
One (
1 ) license plate bracket constructed of stainless steel will be provided at the rear of the apparatus.
One (
1 ) white LED light with
chrome housing
will be provided to illuminate the license plate. A
stainless steel light shield will be provided over the light that will direct illumination downward, preventing white light to the rear.
0556842
Bezels, Wln, (2) M6 Chrome Pierce,
For mtg (4) Wln M6 lights
LIGHTING BEZEL
There will be two (
2 ) Whelen, Model M
6 FCV
4 P, four (
4 ) place chromed ABS housings with Pierce
logos provided for the rear M
6 series stop/tail, directional, back up, scene lights or warning lights. 0589905
Alarm, Back-up Warning, PRECO
1040
BACK-UP ALARM
A PRECO, Model
1040
, solid-state electronic audible back-up alarm that actuates when the truck is shifted into reverse will be provided. The device will sound at 60 pulses per minute and
automatically adjust its volume to maintain a minimum ten ( 10 ) dBA above surrounding
environmental noise levels.
0769569
Lights, Perimeter Cab, Amdor AY-LB-
12HW012 LED 4Dr
CAB PERIMETER SCENE LIGHTS
There will be four (
4 ) Amdor, Model AY-LB-
12 HW
012
,
190
lumens each,
12.00 " white LED strip
lights provided.
One (
1 ) under the driver's side cab access step.
One (
1 ) under the passenger's side cab access step.
One (
1 ) under the passenger's side crew cab access step.
One (
1 ) under the driver's side crew cab access step.
The lights will be activated when the battery switch is on and the respective door is open and whenever control has been selected for the body perimeter lights. 35 931
Bid #:
0769559
Lights, Perimeter Pump House,
Amdor AY-LB-12HW012 LED 2lts
PUMP HOUSE PERIMETER LIGHTS
There will be two (
2 ) Amdor, Model AY-LB-
12 HW
012
,
190
lumens each,
12.00 " LED
weatherproof strip lights with brackets provided under the pump panel running boards, centered front to rear as much as possible, one (
1 ) each side.
The lights will be activated when the battery switch is on, and controlled by the same means as the body perimeter lights.
0769560
Lights, Perimeter Body, Amdor AY-
LB-12HW012 LED 2lts, Rear Step
BODY PERIMETER SCENE LIGHTS
There will be two (
2 ) Amdor, Model AY-LB-
12 HW
012
,
190
lumens each,
12.00 "
12 volt DC LED
strip lights provided at the rear step area of the body, one ( 1 ) each side shining to the rear.
The perimeter scene lights will be activated when
a switch within reach of the driver is activated
and the parking brake is applied
.
0896454
Enhanced Software for Perimeter Lts
ENHANCED SOFTWARE FOR PERIMETER LIGHTS
All perimeter lights will be deactivated when the parking brake is released unless alternate control is selected.
The cab and crew cab perimeter lights will remain on for ten ( 10 ) seconds for improved visibility
after the doors closed.
0556360
Lights, Step, P25 LED 4lts, Pump Pnl
Sw
STEP LIGHTS
Four (
4 ) white LED step lights will be provided. One (
1 ) step light will be provided on each side,
on the front compartment face and two (
2 ) step lights at the rear to illuminate the tailboard.
In order to ensure exceptional illumination, each light will provide a minimum of 25 foot-candles
(fc) covering an entire
15.00 " x
15.00 " square placed
10.00 " below the light and a minimum of
1.5 fc covering an entire
30.00 " x
30.00 " square at the same
10.00 " distance below the light.
These step lights will be actuated with the pump panel light switch.
All other steps on the apparatus will be illuminated per the current edition of NFPA 1901
.
0698585
Lights, Side Scene, Wln M9LZC
Gradient LED, 2nd,
SCENE LIGHTS
There will be
one (
1 )
Whelen, Model M
9 LZC LED scene light(s) with chrome flange(s) installed on the side of the apparatus,
on the passenger side behind the crew cab door near the roofline and matching the driver side
.
A control for the light(s) selected above will be the following:
a switch at the driver's side switch panel
a switch at the passenger's side switch panel
a switch at the pump operator's panel
no additional switch location
These lights may be load managed when the parking brake is set. 0698589
Lights, Side Scene, Wln M9LZC
Gradient LED, 1st
SIDE SCENE LIGHTS
There will be
one (
1 )
Whelen®, Model M
9 LZC, LED scene light(s) with Model M
9 FC, chrome
flange(s) installed on the side of the apparatus,
one (
1 ) high and rearward of driver's side crew
cab door
.
A control for the light(s) selected above will be the following:
a switch at the driver's side switch panel
a switch at the pump operator's panel
a switch at the passenger's side switch panel
no additional switch location
These lights may be load managed when the parking brake is applied. 0776075
Light, Visor, Wln, 12V P*H1* Pioneer
LED 1st
12 VOLT LIGHTING
There will be
one (
1 )
Whelen® Model P*H
1 *,
8,875
lumens
12 volt DC LED light(s)
with flood
optics
provided on the front visor,
centered
.
The housing(s)
painted parts of this light assembly to be white
.
The light(s) will be controlled
by a switch at the driver's side switch panel, by a switch at the left side pump panel and by a switch at the passenger's side switch panel .
These light(s) may be load managed when the parking brake is applied. 0774308
Lights, Wln, P*H2* Pioneer, 12 VDC,
2nd
12 VOLT DC SCENE LIGHTS
There will be
one (
1 )
Whelen® Model P*H
2 *,
17,750
lumens
12 volt DC powered lights with white
LEDs and
flood optics
installed on the apparatus located,
back wall of the cab on the passenger
side
.
The
light(s) to be installed on push up side mount, outside pole length to be
12.00 " long with
handle holder and sensor connecting the pole to the Do Not Move Truck Indicator circuit .
The
painted parts of this light assembly to be white
.
The lights will be activated
by a switch at the driver's side switch panel, by a switch at the passenger's side switch panel and by a switch at the right side pump panel .
The light(s) may be load managed when the parking brake is applied. 36 931
Bid #:
0774309
Lights, Wln, P*H2* Pioneer, 12 VDC,
1st
12 VOLT DC SCENE LIGHTS
There will be
one (
1 )
Whelen® Model P*H
2 *,
17,750
lumens
12 volt DC powered lights with white
LEDs and
flood optics
installed on the apparatus located,
back wall of the cab on the driver side
.
The
light(s) to be installed on push up side mount, outside pole length to be
12.00 " long with
handle holder and sensor connecting the pole to the Do Not Move Truck Indicator circuit .
The
painted parts of this light assembly to be white
.
The lights will be activated
by a switch at the driver's side switch panel and by a switch at the left side pump panel
.
The light(s) may be load managed when the parking brake is applied. 0532358
Not Required, Deck Lights, Other
Hose Bed & Rear Lighting
0645675
Lights, Not Required, Hose Bed, Alt.
Pole Lights On Back Of Cab/In Pump
House
0645677
Lights, Not Required, Rear Work, Alt.
12 Volt Lights At Rear Body
0645683
Lights, Rear Scene, Wln, M9LZC
LED
REAR SCENE LIGHT(S)
There will be
two (
2 )
Whelen®, Model M
9 LZC, LED scene light(s) with chrome trim bezel(s)
installed at the rear of the apparatus,
one (
1 ) each side high on rear body bulkhead
.
The light(s) will be controlled
by a switch at the driver's side switch panel, by a switch at the passenger's side switch panel and by a cup switch at the driver's side rear bulkhead .
The light(s) may be load managed when the parking brake is applied. 0709438
Lights, Walk Surf, FRP Flood, LED
WALKING SURFACE LIGHT
There will be Model FRP,
4 " round black
12 volt DC LED floodlight(s) with bolt mount provided to illuminate the entire designated walking surface on top of the body.
The light(s) will be activated when the body step lights are on. 0744860
SP
Switch, 12VDC, Connect to Fill in
Blank, Sw Type
SWITCH, ADDITIONAL
Additional
12 V switch(es) will be provided. There will be
two (
2 ) switches
located
One (
1 ) LS EMS
Compartment. In place of roll-up door magnetic Switch. Maintain exterior door switch. One ( 1 ) RS
EMS Compartment. In place of roll-up door magnetic Switch. Maintain exterior door switch.
Switches mounted on exterior frame of cabinet and fac
to control
EMS Cabinet Light
. The switch
will be a
rocker style
.
0086038
Switch(es), 12VDC, 30Amp Connect
to Fill in Blank
SWITCH, ADDITIONAL
Additional
12 V switch(es) will be provided. There will be
one (
1 ) switch
located
on the driver side
switch panel and matching job
33716
and in location
10 (slot
#6
)
to control
battery direct switch in
the power source run to the area on the back wall of the EMS cabinet just behind the officer seat and configured as a momentary switch that momentarily interrupts power .
0060111
Pumper, Medium, Galvanneal, 2nd
Gen
0554271
Body Skirt Height, 20"
37 931
Bid #:
0028244
Tank, Water, 500 Gallon, Poly, Med
WATER TANK
Booster tank will have a capacity of
500
gallons and be constructed of polypropylene plastic by
United Plastic Fabricating, Incorporated.
Tank joints and seams will be nitrogen welded inside and out.
Tank will be baffled in accordance with NFPA Bulletin
1901
requirements.
Baffles will have vent openings at both the top and bottom to permit movement of air and water between compartments.
Longitudinal partitions will be constructed of .
38 " polypropylene plastic and will extend from the
bottom of the tank through the top cover to allow for positive welding.
Transverse partitions will extend from
4.00 " off the bottom of the tank to the underside of the top cover.
All partitions will interlock and will be welded to the tank bottom and sides.
Tank top will be constructed of .
50 " polypropylene. It will be recessed .
38 " and will be welded to
the tank sides and the longitudinal partitions.
Tank top will be sufficiently supported to keep it rigid during fast filling conditions.
Construction will include
2.00 " polypropylene dowels spaced no more than
30.00 " apart and
welded to the transverse partitions. Two (
2 ) of the dowels will be drilled and tapped (.
50 "
diameter,
13.00 " deep) to accommodate lifting eyes.
A sump that will be sized dependent on the tank to pump plumbing will be provided at the bottom of the water tank.
Sump will include a drain plug and the tank outlet.
Tank will be installed in a fabricated cradle assembly constructed of structural steel.
Sufficient crossmembers will be provided to properly support bottom of tank. Crossmembers will be constructed of steel bar channel or rectangular tubing.
Tank will "float" in cradle to avoid torsional stress caused by chassis frame flexing. Rubber cushions, .
50 " thick x
3.00 " wide, will be placed on all horizontal surfaces that the tank rests on.
Stops or other provision will be provided to prevent an empty tank from bouncing excessively while moving vehicle.
Mounting system will be approved by the tank manufacturer. 0003405
Overflow, 4.00" Water Tank, Poly
Fill tower will be constructed of .
50 " polypropylene and will be a minimum of
8.00 " wide x
14.00 "
long.
Fill tower will be furnished with a .
25 " thick polypropylene screen and a hinged cover.
An overflow pipe, constructed of
4.00 " schedule
40 polypropylene, will be installed approximately
halfway down the fill tower and extend through the water tank and exit to the rear of the rear axle. 0028104
Foam Cell Required
0010755
Drain, Tank - 2.00"
TANK DRAIN
A
2.00 " tank drain will be installed with a
2.00 " ball valve located underneath the left front
compartment that is properly labeled.
0633066
Sleeve, Through Tank
SLEEVE, PLUMBING, THROUGH TANK
One (
1 ) sleeve
will be provided in the water tank for
a
3.00 " pipe
to the rear.
0553729
Not Required, Restraint, Water Tank,
Heavy Duty
0003429
Not Required, Direct Tank Fill
0003424
Not Required, Dump Valve
0048710
Not Required, Jet Assist
0030007
Not Required, Dump Valve Chute
0514778
Not Required, Switch, Tank Dump
Master
0126632
Hose Bed, Galv, Pumper
HOSE BED
The hose bed will be fabricated of
12 -gauge galvanneal steel.
The sides will not form any portion of the fender compartments.
Upper and rear edges of side panels will have a double break for rigidity.
The upper inside area of the beavertails will be covered with brushed stainless steel to prevent damage to painted surface when hose is removed.
Flooring of the hose bed will be removable aluminum grating with the top surface corrugated to aid in hose aeration. The grating slats will be a minimum of
0.50 " x
4.50 " with spacing between
slats for hose ventilation.
38 931
Bid #:
0723549
Painted Hose Bed
The hose bed interior walls will be painted
to match the lower body color
.
0003481
Hose Bed Capacity, Special
Hose bed will accommodate
500' of 1.75" in section #1, 400' of 2.5" in section #2, 400' of 2.5" of double stack in section #3, and 850' of 5" in triple stack in section #4 (Match Job 33716) .
0003488
Divider, Hose Bed, Unpainted
HOSE BED DIVIDER
Three (
3 ) hosebed dividers
will be furnished for separating hose.
Each divider will be constructed of a .
125
" brushed aluminum sheet fitted and fastened into a
slotted,
1.50 " diameter radiused extrusion along the top, bottom, and rear edge.
Divider will be fully adjustable by sliding in tracks, located at the front and rear of the hose bed.
Divider will be held in place by tightening bolts, at each end.
Acorn nuts will be installed on all bolts in the hose bed which have exposed threads. 0754097
Mounting, Seat Belt Buckle, Hose
Bed Restraint, Rear, Bottom, Hinged
RESTRAINT MOUNTING
The seat belt buckles at the bottom of the hose bed will be hinge mounted to allow the piece mounted below the hose bed to move out of the way during hose deployment. 0581892
Divider, .25", Unpainted, Permanent
There will be
one (
1 )
additional hose bed dividers furnished.
Each divider will be constructed of a .
25 " brushed aluminum sheet.
Partition will be permanently installed and located
right side of hose bed separating the hard
suction hose from hose bay
#4
. Match job
33716
.
Acorn nuts will be installed on all bolts in the hose bed which have exposed threads.
Flat surfaces will be sanded for uniform appearance or constructed of brushed aluminum. 0039197
Removable Shelf In Hose Bed, Shelf
Only
SHELF, IN HOSE BED
one (
1 )
removable shelf, made of grating, will be provided for hose storage inside the hose bed.
The shelf will be mounted
over the hard suction hose trays running from the front of the hose bed to the rear between the passenger side side sheet and the divider and approximately 6 " in width.
Match Job
33716
.
0585445
SP
Cover, Hose Bed, Alum Treadplate,
Right Side Open First
HOSE BED COVER
A two (
2 ) section hose bed cover, constructed of .
125
" bright aluminum treadplate, will be
furnished. The cover will be hinged with full length stainless steel piano hinge. The sides will be slanted down.
The right side cover will open first.
The cover will be reinforced so that it can support the weight of a man walking on the cover.
If access to water tank fill tower is blocked by the hose bed cover, then a hinged door will be provided in it so that tank may be filled without raising cover doors.
Chrome grab handles and four (
4 ) gas filled cylinders will be provided to assist in opening and closing the cover. A handrail is provided at the rear, in the center of the support, to assist in opening the cover.
The hose bed cover will be connected to the Do Not Move Truck indicator. The light will be activated if the cover is not in the stowed position and the parking brake is released. 0697328
Flap, Rear of Alum Hose Bed Cover,
Two Piece, Vinyl, w/Seat Belt
Buckles
HOSEBED END FLAP
A pair of
red
vinyl flaps will be installed on the rear, one for each of the aluminum treadplate hose bed covers. The vinyl flap will be secured to the hose bed cover with quarter turn fasteners.
Each vinyl flap will have (
2 ) nylon tie down straps with seat belt buckles to secure the flaps at their base.
0013512
Running Boards, 12.75" Deep
RUNNING BOARDS
Running boards will be fabricated of .
125
" bright aluminum treadplate.
Each running board will be supported by a welded
2.00 " square tubing and channel assembly,
which will be bolted to the pump compartment substructure.
Running boards will be
12.75 " deep and spaced .
50 " away from the pump panel.
A splash guard will be provided above the running board treadplate. 0678630
SP
Tailboard, 20" & 4" Deep, Non-Step,
T-Shaped, Angled Corners
TAILBOARD
The tailboard will also be constructed of .
125
" bright aluminum treadplate and spaced .
50 " from
the body, as well as supported by a structural steel assembly.
The tailboard area will be
20.00 " deep in the center area and
4.00 " deep to the rear of the side
compartments. The tailboard will be T-shaped. The
4.00 " extension to the rear of the side
compartments will be angled up to prevent this area from being used as a stepping surface.
The outboard sides of the tailboard will be angled at
45 degrees beginning at the point where the
body meets the tailboard at the forward outboard edge angling rearward to the rear edge of the tailboard.
The exterior side will be flanged down and in for increased rigidity of tailboard structure. 39 931
Bid #:
0690037
Wall, Rear, Smooth Aluminum/Body
Material
REAR WALL, SMOOTH ALUMINUM/BODY MATERIAL
The rear facing surfaces of the center rear wall will be smooth aluminum.
The bulkheads, the surface to the rear of the side body compartments, will be smooth and the same material as the body.
Any inboard facing surfaces below the height of the hosebed will be aluminum diamondplate
.
0889214
Tow Eyes, w/Tow Bar, 2G Pumper
REAR TOW EYES
Two (
2 ) tow eyes, which are an integral part of the body mounting substructure, will be installed below the rear of the truck.
The tow eyes will be of adequate strength to allow the truck to be pulled from the eyes.
REAR TOW BAR
One (
1 ) tow bar will be installed under the tailboard.
The tow bar assembly will be designed and positioned to allow up to a 30 -degree upward angled
pull of
17,000
lb, or a
20,000
lb straight horizontal pull in line with the centerline of the vehicle.
The tow bar design will have been tested and evaluated using finite element analysis techniques. 0623362
Hose Restraint, Running Board,
Straps, S/S Seat Belt Buckle Style
Latch
RUNNING BOARD HOSE RESTRAINT
A pair of
2.00 " wide black nylon straps with stainless steel seat belt buckle style latches will be provided for each hose tray to secure the hose during travel. There will be Two (
2 ) hose trays
located
one (
1 ) in each side running board
.
0014112
Tray, Hose, Running Board, Special
Capacity, Predefined
HOSE TRAY
Two (
2 ) hose trays
will be recessed
one (
1 ) in each side running board
.
Capacity of the tray will be
25 ' of
5.00 " hose
.
Rubber matting will be installed on the floor of the tray to provide proper ventilation. Drain holes will be provided.
40 931
Bid #:
0895816
Construction, Compt, Galv, 2G
Pumper
COMPARTMENTATION
Body and compartments will be fabricated of galvanneal steel.
Side compartments will be an integral assembly with the rear fenders.
Circular fender liners will be provided for prevention of rust pockets and ease of maintenance.
Side compartment flooring will be
12 -gauge and of the sweep out design, with the floor higher than the compartment door lip.
The side compartment door opening will be framed by flanging the edges in
1.75 " and bending
out again
0.75 " to form an angle.
Drip protection will be provided above the doors by means of bright aluminum extrusion, formed bright aluminum treadplate, or polished stainless steel.
The top of the compartment will be covered with bright aluminum treadplate rolled over the edges on the front, rear, and outward side. These covers will have the corners TIG welded.
Side compartment covers will be separate from the compartment tops.
Front facing compartment walls will be covered with bright aluminum treadplate.
All screws and bolts which protrude into a compartment will have acorn nuts on the ends to prevent injury.
UNDERBODY SUPPORT SYSTEM
Due to the severe loading requirements of this pumper, a method of body and compartment support suitable for the intended load will be provided.
The backbone of the support system will be the chassis frame rails, which is the strongest component of the chassis and designed for sustaining maximum loads.
The support system will include
0.375
" thick steel vertical angle supports bolted to the chassis frame rails with
0.625
" diameter bolts.
Attached to the bottom of the steel vertical angles will be horizontal angles, with gussets welded to the vertical members, which extend to the outside edge of the body.
A steel frame will be mounted on the top of these supports to create a floating substructure, which results in a
500
lb equipment support rating per lower compartment.
The steel frames as well as the steel vertical angles will be treated with an epoxy E-coat to provide resistance to corrosion and chemicals as standard.
The floating substructure will be separated from the horizontal members with neoprene elastomer isolators. These isolators will reduce the natural flex stress of the chassis from being transmitted to the body.
The isolators will have a broad load range, proven viability in vehicular applications, be of a fail safe design and allow for all necessary movement in three ( 3 ) transitional and rotational modes.
The neoprene isolators will be installed in a modified V three ( 3 )-point mounting pattern to reduce
the natural flex of the chassis being transmitted to the body.
A design with body compartments hanging on the chassis, unsupported, will not be acceptable.
AGGRESSIVE WALKING SURFACE
All exterior surfaces designated as stepping, standing, and walking areas will comply with the required average slip resistance of the current NFPA standards.
LOUVERS
Louvers will be stamped into compartment walls to provide the proper airflow inside the body compartments and to prevent water from dripping into the compartment. Where these louvers are provided, they will be formed into the metal and not added to the compartment as a separate plate.
TESTING OF BODY DESIGN
Body structural analysis will be fully tested. Proven engineering and test techniques such as finite element analysis, strain gauging, and model analysis will be performed with special attention given to fatigue, life and structural integrity of the cab, body and substructure.
The body will be tested while loaded to its greatest in-service weight.
The criteria used during the testing procedure will include:
Raising opposite corners of the vehicle tires
9.00 ", simulating the twisting a truck may experience
when driving over a curb.
Making a
90 degree turn while at
20 mph, simulating aggressive driving conditions.
Driving the vehicle at
35 mph on a washboard road.
Driving the vehicle at
55 mph on a smooth road.
Accelerating the vehicle fully, until reaching the approximate speed of 45 mph, on rough
pavement.
Evidence of actual testing techniques will be made available upon request. 0023650
LS 152" Rollup, Full Height Front &
Rear, FDLER
LEFT SIDE COMPARTMENTATION
The left side compartmentation will consist of three rollup door compartments.
A full height, rollup door compartment ahead of the rear wheels will be provided. The interior dimensions of this compartment will be
34.50 " wide x
66.63 " high x
25.88 " deep in the lower
25.00 " of the compartment and
12.00 " deep in the remaining upper portion. The clear door opening will be a minimum of
28.75 " wide x
56.88 " high.
A rollup door compartment over the rear wheels will be provided. The interior dimensions of this compartment will be
66.50 " wide x
32.88 " high x
12.00 " deep. The clear door opening will be a
minimum of
58.25 " wide x
23.13 " high.
A full height, rollup door compartment behind the rear wheels will be provided.
The interior
dimensions of this compartment will be
47.75 " wide x
67.63 " high x
25.88 " deep in the
lower
26.00 " of height and
12.00 " deep in the remaining upper section of the compartment.
The clear door opening will be a minimum of
44.75 " wide x
57.88 " high.
The interior height of the compartments will be measured from the compartment floor to the ceiling. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartments will be measured from the back wall to the inside of the door frame.
Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.
41 931
Bid #:
0063658
RS 152" Rollup, Full Height Front &
Rear, FDLER
RIGHT SIDE COMPARTMENTATION
The right side compartmentation will consist of three rollup door compartments.
A full height, rollup door compartment ahead of the rear wheels will be provided. The interior dimensions of this compartment will be
34.50 " wide x
66.63 " high x
25.88 " deep in the lower
25.00 " of the compartment and
12.00 " deep in the remaining upper portion. The clear door opening will be a minimum of
28.75 " wide x
56.88 " high.
A rollup door compartment over the rear wheels will be provided. The interior dimensions of this compartment will be
66.50 " wide x
32.88 " high x
12.00 " deep. The clear door opening will be a
minimum of
58.25 " wide x
23.13 " high.
A full height, rollup door compartment behind the rear wheels will be provided.
The interior
dimensions of this compartment will be
47.75 " wide x
67.63 " high x
25.88 " deep in the
lower
26.00 " of height and
12.00 " deep in the remaining upper section of the compartment.
The clear door opening will be a minimum of
44.75 " wide x
57.88 " high.
The interior height of the compartments will be measured from the compartment floor to the ceiling. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartments will be measured from the back wall to the inside of the door frame.
Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.
0692733
Doors, Rollup, Gortite, Side
Compartments
SIDE COMPARTMENT ROLLUP DOOR(S)
There will be
six (
6 ) compartment doors
installed on the side compartments. The doors will be
double faced aluminum construction,
painted one (
1 ) color to match the lower portion of the body
and manufactured by Gortite®.
Lath sections will be an interlocking rib design and will be individually replaceable without complete disassembly of door.
Between each slat at the pivoting joint will be a PVC inner seal to prevent metal to metal contact and prevent dirt or moisture from entering the compartments. Seals will allow door to operate in extreme temperatures ranging from
180
to -
40 degrees Fahrenheit. Side, top and bottom seals
will be provided to resist ingress of dirt and weather and be made of Santoprene.
All hinges, barrel clips and end pieces will be nylon
66 . All nylon components will withstand
temperatures from
300
to -
40 degrees Fahrenheit.
A polished stainless steel lift bar with locking key latches to be provided for each roll-up door. The keys to be Model
1250
for all compartment doors
. Lift bar will be located at the bottom of door
and have latches on the outer extrusion of the doors frame. A ledge will be supplied over lift bar for additional area to aid in closing the door.
Doors will be constructed from an aluminum box section. The exterior surface of each slat will be flat. The interior surfaces will be concave to provide strength and prevent loose equipment from jamming the door from inside.
To conserve space in the compartments, the spring roller assembly will not exceed
3.00 " in
diameter.
The header for the rollup door assembly will not exceed
4.00 ".
A heavy-duty magnetic switch will be used for control of open compartment door warning lights. 0083700
Compt, Rear, Rollup, 37.75" FF,
25.88" D
REAR COMPARTMENTATION
A roll-up door compartment above the rear tailboard will be provided .
The interior dimensions of this compartment will be
40.00 " wide x
40.63 " high x
25.88 " deep. The
spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartment will be calculated with the compartment door closed.
A louvered, removable access panel will be furnished on the back wall of the compartment.
The rear compartment will be open into the rear side compartments.
The clear door opening of this compartment will be a minimum of
33.25 " wide x
30.88 " high.
Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.
0692746
Door, Gortite, Rollup, Rear
Compartment
ROLLUP REAR COMPARTMENT DOOR
There will be a rear rollup door. The door will be double faced aluminum construction, an
anodized satin finish
and manufactured by Gortite®.
Lath sections will be an interlocking rib design and will be individually replaceable without complete disassembly of door.
Between each slat at the pivoting joint will be a PVC inner seal to prevent metal to metal contact and prevent dirt or moisture from entering the compartments. Seals will allow door to operate in extreme temperatures ranging from
180
to -
40 degrees Fahrenheit. Side, top and bottom seals
will be provided to resist ingress of dirt and weather and be made of Santoprene.
All hinges, barrel clips and end pieces will be nylon
66 . All nylon components will withstand
temperatures from
300
to -
40 degrees Fahrenheit.
A polished stainless steel lift bar with locking key latches to be provided for each roll-up door. The keys to be Model
1250
for all compartment doors
. Lift bar will be located at the bottom of door
and have latches on the outer extrusion of the doors frame. A ledge will be supplied over lift bar for additional area to aid in closing the door.
Door will be constructed from an aluminum box section. The exterior surface of each slat will be flat. The interior surface will be concave to provide strength and prevent loose equipment from jamming the door from inside.
To conserve space in the compartments, the spring roller assembly will not exceed
3.00 " in
diameter.
The header for the rollup door assembly will not exceed
4.00 ".
A heavy-duty magnetic switch will be used for control of open compartment door warning lights. 0554995
No Body Modification Required
42 931
Bid #:
0019845
Guard, Drip Pan, S/S, Rollup Door
DOOR GUARD
There will be
six (
6 ) compartment doors
that will include a guard/drip pan designed to protect the roll-up door from damage when in the retracted position and contain any water spray. The guard will be fabricated from stainless steel and installed
body side compartments (LS-
1 , LS-
2 , LS-
3 ,
RS-
1 , RS-
2 , and RS-
3 )
.
0659353
Lights, Compt, Amdor AY-9220 LED,
Dual Lt Strip
COMPARTMENT LIGHTING
There will be
seven (
7 )
compartments with Amdor, Model AY-
9220
, white
12 volt DC LED
compartment light strips. The lights will be mounted with mechanical fasteners.
There will be two (
2 ) strip lights installed vertically in each compartment opening per the latest NFPA requirements.
The lights will be activated when the battery switch is on and the respective compartment door is opened.
0687146
Shelf Tracks, Painted
MOUNTING TRACKS
There will be
six (
6 ) sets of tracks
for mounting shelf(s) in
LS
1 , LS
2 , LS
3 , RS
1 , RS
2 and RS
3 .
These tracks will be installed vertically to support the adjustable shelf(s). The tracks will be painted to match the compartment interior.
0600350
Shelves, Adj, 500 lb Capacity, Full
Width/Depth, Predefined Locations
ADJUSTABLE SHELVES
There will be
ten (
10 ) shelves
with a capacity of
500
lb provided.
The shelf construction will consist of .
188
" aluminum
painted spatter gray
with
2.00 " sides.
Each shelf will be infinitely adjustable by means of a threaded fastener, which slides in a track.
The shelves will be held in place by .
12 " thick stamped plated brackets and bolts.
The location(s) will be
in LS
1 at the depth transition point, in RS
3 at the transition point, in RS
1 at
the transition point to the right of partition, in RS
2 centered between the floor and the ceiling, in
RS
3 in the lower third, in RS
3 in the upper third, in RS
1 in the upper third to the right of the
partition, in LS
2 in the lower third, in LS
3 in the lower third and in LS
2 in the upper third
.
0709690
Tray, 250 lb Slide-out, 2" Sides - Adj.
Height, Predefined Locations
SLIDE-OUT ADJUSTABLE HEIGHT TRAY
There will be
one (
1 ) slide-out tray
provided.
Each tray will have
2.00 " high sides and a minimum capacity rating of
250
lb in the extended
position.
Each tray will be constructed of aluminum
painted spatter gray
.
Each tray will be mounted on a pair of side mounted slides. The slide mechanisms will have ball bearings for ease of operation and years of dependable service. The slides will be mounted to shelf tracks to allow the tray to be adjustable up and down within the designated mounting location.
An automatic lock will be provided for both the in and out tray positions. The lock trip mechanism will be located at the front of the tray and will be easily operated with a gloved hand.
The location(s) will be
in LS
3 in the lower third
0647091
Tray, Floor Mounted, Slide-Out,
500lb, 2.00" Sides
SLIDE-OUT FLOOR MOUNTED TRAY
There will be
one (
1 )
floor mounted slide-out tray(s) provided.
Each tray will have
2.00 " high sides and a minimum capacity rating of
500
lb in the extended
position.
Each tray will be constructed of aluminum
painted spatter gray
There will be two undermount-roller bearing type slides rated at 250
lb each provided. The pair of
slides will have a safety factor rating of
2 .
To ensure years of dependable service, the slides will be coated with a finish that is tested to withstand a minimum of
1,000
hours of salt spray per ASTM B
117
.
To ensure years of easy operation, the slides will require no more than a 50 lb force for push-in or
pull-out movement when fully loaded after having been subjected to a 40 hour vibration (shaker)
test under full load. The vibration drive file will have been generated from accelerometer data collected from a heavy truck chassis driven over rough gravel roads in an unloaded condition.
Proof of compliance will be provided upon request.
Automatic locks will be provided for both the "in" and "out" positions. The trip mechanism for the locks will be located at the front of the tray for ease of use with a gloved hand.
The location(s) will be
B
1 .
0726403
Partition, Vertical Compt, Special
Height
VERTICAL COMPARTMENT PARTITION
One (
1 ) partition
will be bolted in
RS
1 ,
23.00 " from the left wall and terminating
6 " below the
ceiling of the compartment and (matching job
33716
)
. Each partition will be
Within
6 " of the
ceiling of the RS
1 compartment
vertical height of the compartment. Each partition will be painted
spatter gray
.
0003934
Dust Filter, Compt Louvers
COMPARTMENT DUST FILTERS
A total of
one (
1 )
body compartment louvers will have a removable dust filter installed to restrict road dirt from easily entering the compartment and will be installed compartment ahead of the
rear axle on the passenger side (RS-
3 )
.
43 931
Bid #:
0755526
Pegboard, Back Wall Mounted, 3/16"
Alum, Special
PEGBOARD
There will be
3/16
" thick aluminum pegboard
spatter gray painted
installed on the back wall of
one (
1 )
compartments. It will be mounted using two (
2 ) horizontal tracks. Retainers will be used to
mount the pegboard to the tracks. The holes will be
.
203
" diameter
, punched
1.00 " on center.
The pegboard will be located in the
LS
3 and mounted
in the back wall of the upper section of
LS-
3 but minimize the space for the inverter and breaker panel so that the space for the pegboard can be maximized (match job
31136
)
.
0004020
Rub Rail, Stainless Steel
RUB RAIL
The bottom edge of the side compartments will be trimmed with a bright stainless steel rub rail.
The rub rail will be
2.00 " high and extend
1.00 " away from the body, with slanted ends to provide a pleasing appearance.
These rub rails will not be an integral part of the body construction, which allows replacement in the event of damage.
0784811
Fender Crowns, Rear, Stainless,
w/Removable Liner
BODY FENDER CROWNS
Polished stainless steel fender crowns will be provided around the rear wheel openings with a dielectric barrier will be provided between the fender crown and the fender sheet metal to prevent corrosion.
The fender crowns will be held in place with stainless steel screws that thread directly into a composite nut and not directly into the parent body sheet metal to eliminate dissimilar metals contact and greatly reduce the chance for corrosion. Rubber welting will be provided between the body and crown.
BODY FENDER LINER
A
painted to match the lower body color
fender liner will be provided. The liners will be removable to aid in the maintenance of rear suspension components. 0034065
Hose, Hard Suction, 3.0", 10.0', Clear
Corrugated, w/2.5" Couplings
HARD SUCTION HOSE
Two (
2 ) lengths
of
3.00 " clear corrugated PVC hard suction hose,
10 ' in length, will be provided.
The hose will be equipped with a
2.50 " NST long handle female coupling on one (
1 ) end and a
2.50 " NST rocker lug male coupling on the other end. Couplings will be hard coated aluminum. 0615023
Storage, HSH, (2), Hose Bed,
Stacked, Trough, Strap
HOSE TROUGH
A quantity of two (
2 ) hard suction hoses will be carried in troughs, mounted one ( 1 ) above the
other inside the hose bed, located
on the right side
of the hose bed.
Troughs will be constructed of
aluminum unpainted
.
This option will include a hosebed divider.
A hook and loop strap will be provided at the rear of the troughs to contain the hard suction hose.
A section of aluminum treadplate is provided above the storage area. 0626229
Handrails, Side Pump Panels, Per
Print
HANDRAILS
The handrails will be
1.25 " diameter knurled aluminum to provide a positive gripping surface.
Chrome plated end stanchions will support the handrail. Plastic gaskets will be used between end stanchions and any painted surfaces.
Drain holes will be provided in the bottom of all vertically mounted handrails.
Handrails will be provided to meet NFPA
1901
section
15.8 requirements. The handrails will be
installed as noted on the sales drawing.
0004126
Handrails, Beavertail, Standard
HANDRAILS
One (
1 ) vertical handrail will be located on each rear beavertail. 0082756
Handrail, Rear, Below Hose Bed
One (1) knurled aluminum handrail will be installed below the hose bed. 0636301
Compt, Extinguisher (2) Fender
Panel, Triangular Door
EXTINGUISHER/AIR BOTTLE/ STORAGE (Triangular)
A total of
one (
1 )
extinguisher/air bottle/storage compartments will be provided right side ahead of
the rear axle
. The triangular shaped compartment will be sized to fit a
8.00 " diameter extinguisher
in the lower area and a
8.00 " diameter extinguisher in the upper area. The compartment will be approximately
25.50 " deep. A partition will be provided to separate the compartment. Also inside the compartment,
black rubber matting
will be provided. The compartment will be furnished with a drain hole. A
polished
stainless steel, triangular shaped door with a
chrome plated flush lift & turn
latch
will be provided to contain the air bottles. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body sheet metal.
AIR BOTTLE COMPARTMENT STRAP
A strap will be provided in the air bottle compartment(s) to help contain the bottles when the vehicle is parked on an incline. The strap will wrap around the neck and attach to the wall of the compartment.
44 931
Bid #:
0654143
Compt, Air Bottle, Single,Tri Door
(DEF/Fuel), Fender Panel
AIR BOTTLE STORAGE (Single)
A quantity of one air bottle compartment, approximately
7.50 " wide x
7.50 " tall x
26.00 " deep, will
be provided on the driver side rearward of the rear wheels. The triangular door will cover the air bottle opening, the DEF tank access, and fuel fill. The compartment will be square with angled corners. A
polished
stainless steel door with a
chrome plated flush lift & turn latch
will be provided
to contain the air bottle. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body sheet metal.
Inside the compartment,
black rubber matting
will be provided.
AIR BOTTLE COMPARTMENT STRAP
A strap will be provided in the air bottle compartment to help contain the air bottle when the vehicle is parked on an incline. The strap will wrap around the neck and attach to the wall of the compartment.
0657522
Compt, Air Bottle, Triple, Fender
Panel
AIR BOTTLE STORAGE (Triple)
A quantity of
two (
2 ) air bottle compartments
designed to hold (
3 ) air bottles up to
7.25 " in
diameter x
26.00 " deep will be provided
on the left side forward of the rear wheels and on the
right side rearward of the rear wheels
. A
polished
stainless steel door with a
chrome plated flush
lift & turn latch
will be provided to contain the air bottle. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body sheet metal.
Inside the compartment,
black rubber matting
will be provided.
AIR BOTTLE COMPARTMENT STRAP
A strap will be provided in the air bottle compartment(s) to help contain the air bottles when the vehicle is parked on an incline. The strap will wrap around the neck and attach to the wall of the compartment.
0004225
Ladder, 24' Duo-Safety 900A 2-
Section
EXTENSION LADDER
There will be a
24 ' two-section aluminum Duo-Safety Series
900
-A extension ladder provided.
0004230
Ladder, 14' Duo-Safety 775A Roof
ROOF LADDER
There will be a
14 ' aluminum Duo-Safety Series
775
-A roof ladder provided.
0787027
Ladders Btwn Tank & S.Sht, RS,
Ext'd Rr, Encl'd Complete, RPH,
Special Mounting
LADDER STORAGE
The ladders will be stored between the water tank and the right side compartments.
The ladders will extend into the pump compartment just to the rear of the water pump discharges.
The ladder storage area will be enclosed as practical by means of sheet metal to protect the ladders from road dirt. The ladders that extend into the pump house will also be enclosed. A black rubber boot will be provided to enclosed the ladders in the gap between the pump house and the body.
Each ladder will be stored vertically in a separate stainless steel storage trough. Each stainless steel trough will be lined with Dura-Surf nylon slides.
A bright aluminum treadplate enclosure will be provided at the rear of the body to properly contain the ladders. This enclosure will extend to the rear of the side body compartments.
The ladders will be stored
With Fly In
.
The enclosure will also include a vertically hinged
aluminum treadplate
door with a
D-handle latch
to access the ladders.
0549226
SP
Ladder, 10' Duo-Safety Folding 585A,
w/Mounting
FOLDING LADDER
One (
1 )
10.00 ' aluminum, Series
585
-A, Duo-Safety folding ladder will be installed
in the driver
side pike pole/folding ladder compartment
.
0761364
Compt, w/Trough, Folding Ladder,
Long Tool Storage Btwn Tank &
S.Sht, LS
FOLDING LADDER STORAGE
One (
1 ) folding ladder will be stored in a compartment on the left side between the tank and side sheet in a stainless steel U-shaped trough.
A door constructed of
smooth aluminum
and hinged
on the bottom
will be provided at the rear
with a
lift and turn latch
.
0554061
Pike Pole, 10' DUO Safety,
Fiberglass, Pumper NFPA
Classification
10 ' PIKE POLE
One (
1 ) pike pole
10 ' long DUO Safety with a fiberglass handle will be provided. 0733148
Tube, Pike Pole 8' or Longer, Btwn
Tank & S.Sht Long Tool Storage
PIKE POLE STORAGE
There will be storage designated
left side
for
Two (
2 ) pike poles
8 ' or longer pike poles stored in a
tube with a
1.38 " notch, to accommodate a New York style pike pole for the head of a pike pole.
This will be located between the side sheet and tank in the folding ladder storage compartment. 0733370
Pike Pole, 6' DUO Safety, Fiberglass
PIKE POLE,
6 '
One (
1 ) pike pole
,
6 ' long Duo Safety with a fiberglass handle, will be provided. 45 931
Bid #:
0785102
Steps, Folding, Front of Body, Cargo
Bed Access, w/LED, Trident
FOLDING STEPS FRONT OF BODY
Folding steps will be provided
full height on the left side and right side
body compartments to
provide access to the cargo bed. Steps will be spaced evenly on the sales drawing. Actual quantity may vary due to pump panel interferences but will meet the NFPA required maximum stepping height.
The Trident steps will be bright finished, non-skid with a black tread coating
on the stepping
surface.
The step will incorporate an LED light to illuminate the stepping surface.
The steps can be used as a hand hold with two openings wide enough for a gloved hand. 0592994
Steps, Folding, Rear of Body, w/LED,
Trident
REAR FOLDING STEPS
Bright finished, non-skid folding steps with
a black tread coating
on the stepping surface will be
provided at the rear. Each step will incorporate an LED light to illuminate the stepping surface.
The steps can be used as a hand hold with two openings wide enough for a gloved hand. 0512558
Platform, Slide Out, 500 lb Capacity,
Alum 4-Way, Full Width
SLIDE-OUT PLATFORM
Two (
2 ) slideout platforms
will be provided
approximately
17 " wide on the driver and passenger
side running boards ahead of the running board hose trough and used to facilitate the loading of the crosslay hose beds (match job
33716
)
. The step will be as wide as possible. The capacity
rating will be
500#
in the extended position. Automatic locks will be provided for both the "in" and "out" positions. The trip mechanism for the locks will be located at the front of the tray for ease of use with a gloved hand.
There will be
an On Scene Solutions Access
white
12 volt DC LED light provided to illuminate the
ground area.
0650260
I Zone Bracket, Pair, Wildland Style
I-ZONE BRACKETS - WILDLAND STYLE
A pair of I-Zone brackets will be provided and mounted at the rear of the apparatus, on the rear
bulkhead at approximately
5 '
8 " above ground level
. The brackets will be designed with adequate
reinforcement to eliminate flexing of the body (oil canning) and not interfere with rear facing lights while carrying hose.
The design of these I-Zone brackets will have a
45 degree receiver and a removable extension
piece that fits into the brackets for carrying hose.
0084388
Step, Full Width, Rear Of Body, 8"
ADDITIONAL STEP
An
8.00 " deep, full width bright aluminum treadplate step will be provided at the rear of the body. 0015499
Pump House, Side Control, 56"
PUMP COMPARTMENT
The pump compartment will be separate from the hose body and compartments so that each may flex independently of the other. It will be a fabricated assembly of steel tubing, angles and channels which supports both the fire pump and the side running boards.
The pump compartment will be constructed of the same material as the body compartmentation.
The pump compartment will be mounted on the chassis frame rails with rubber biscuits in a four point pattern to allow for chassis frame twist.
Pump compartment, pump, plumbing and gauge panels will be removable from the chassis in a single assembly.
PUMP MOUNTING
Pump will be mounted to a substructure which will be mounted to the chassis frame rail using rubber isolators. The mounting will allow chassis frame rails to flex independently without damage to the fire pump.
PUMP CONTROL PANELS (Side Control)
All pump controls and gauges will be located at the left side of the apparatus and properly marked.
The control panels will be
56.00 " wide.
Polished stainless steel trim collars will be installed around all inlets and outlets.
All push/pull valve controls will have
1/4
turn locking control rods with polished chrome plated zinc tee handles. Guides for the push/pull control rods will be chrome plated zinc castings securely mounted to the pump panel. Push/pull valve controls will be capable of locking in any position.
The control rods will pull straight out of the panel and will be equipped with universal joints to eliminate binding.
The identification tag for each valve control will be recessed in the face of the tee handle.
All discharge outlets will have color coded identification tags, with each discharge having its own unique color. Color coding will include the labeling of the outlet and the drain for each corresponding discharge.
All line pressure gauges will be mounted in individual chrome plated castings with the identification tag recessed in the casting below the gauge. All remaining identification tags will be mounted on the pump panel in chrome plated bezels. Mounting of the castings and identification bezels will be done with a threaded peg cast on the back side of the bezel or screws. 0037731
Pump House Structure, Raised,
Included with Ladder Storage
46 931
Bid #:
0608222
Access Door, Cargo Compt, LS, 105
Deg Lift-up Door, Latch & Hold Open
Selections
ACCESS DOOR
A liftup,
aluminum treadplate
door will be provided above the left side pump panel for access to the cargo compartment above the pump. It will have a
D-handle latch and two (
2 ) gas struts
and
be as large as possible.
Each door must open
105
degrees or greater to eliminate being mistaken as a stepping surface.
This door will be labeled as a non-step surface.
0004425
Pump, Waterous, CSU, 1500 GPM,
Single Stage
PUMP
Pump will be a Waterous CSU,
1500
gpm single (
1 ) stage midship mounted centrifugal type.
Pump will be the class "A" type.
Pump will deliver the percentage of rated discharge at pressures indicated below:
-
100%
of rated capacity at
150
psi net pump pressure.
-
70%
of rated capacity at
200
psi net pump pressure.
-
50%
of rated capacity at
250
psi net pump pressure.
Pump body will be close-grained gray iron, bronze fitted, and horizontally split in two ( 2 ) sections
for easy removal of the entire impeller shaft assembly (including wear rings).
Pump will be designed for complete servicing from the bottom of the truck, without disturbing the pump setting or apparatus piping.
Pump case halves will be bolted together on a single horizontal face to minimize chance of leakage and facilitate ease of reassembly. No end flanges will be used.
Discharge manifold of the pump will be cast as an integral part of the pump body assembly and will provide a minimum of three (
3 )
3.50 " openings for flexibility in providing various discharge outlets for maximum efficiency.
The three (
3 )
3.50 " openings will be located as follows: one (
1 ) outlet to the right of the pump, one
(
1 ) outlet to the left of the pump, and one (
1 ) outlet directly on top of the discharge manifold.
Impeller shaft will be stainless steel, accurately ground to size. It will be supported at each end by sealed, anti-friction ball bearings for rigid precise support. Impeller will have flame plated hubs assuring maximum pump life and efficiency despite any presence of abrasive matter in the water supply.
Bearings will be protected from water and sediment by suitable stuffing boxes, flinger rings, and oil seals. No special or sleeve type bearings will be used. 0004482
Seal, Mechanical, Waterous
Pump will be equipped with a self-adjusting, maintenance-free, mechanical shaft seal.
The mechanical seal will consist of a flat, highly polished, spring fed carbon ring that rotates with the impeller shaft. The carbon ring will press against a highly polished stainless steel stationary ring that is sealed within the pump body.
In addition, a throttling ring will be pressed into the steel chamber cover, providing a very small clearance around the rotating shaft in the event of a mechanical seal failure. The pump performance will not deteriorate, nor will the pump lose prime, while drafting if the seal fails during pump operation.
Wear rings will be bronze and easily replaceable to restore original pump efficiency and eliminate the need to replace the entire pump casing due to wear. 0559769
Trans, Pump, Waterous C20 Series
PUMP TRANSMISSION
The pump transmission will be made of a three (
3 ) piece, aluminum, horizontally split casing.
Power transfer to pump will be through a high strength Morse HY-VO silent drive chain. By the use of a chain rather than gears,
50%
of the sprocket will be accepting or transmitting torque, compared to two (
2 ) or three (
3 ) teeth doing all the work.
Drive shafts will be
2.35 " diameter hardened and ground alloy steel and supported by ball bearings. The case will be designed to eliminate the need for water cooling. 0635600
Pumping Mode, Stationary Only
PUMPING MODE
An interlock system will be provided to ensure that the pump drive system components are properly engaged so that the apparatus can be safely operated. The interlock system will be designed to allow stationary pumping only.
0788759
Pump Shift, Air w/o Manual Override,
Split Shaft, Interlocked, Wat, Left
Switch
AIR PUMP SHIFT
Pump shift engagement will be made by a two (
2 ) position sliding collar, actuated pneumatically
(by air pressure), with a three (
3 ) position air control switch located in the cab, on the lower left side switch panel.
Two (
2 ) indicator lights will be provided adjacent to the pump shift inside the cab. One ( 1 ) green
light will indicate the pump shift has been completed and be labeled "pump engaged". The second green light will indicate when the pump has been engaged, and that the chassis transmission is in pump gear. This indicator light will be labeled "OK to pump".
The pump shift will be interlocked to prevent the pump from being shifted out of gear when the chassis transmission is in gear to meet NFPA requirements.
The pump shift control in the cab will be illuminated to meet NFPA requirements. 0003148
Transmission Lock-up, EVS
TRANSMISSION LOCK-UP
The direct gear transmission lock-up for the fire pump operation will engage automatically when the pump shift control in the cab is activated.
47 931
Bid #:
0004547
Auxiliary Cooling System
AUXILIARY COOLING SYSTEM
A supplementary heat exchange cooling system will be provided to allow the use of water from the discharge side of the pump for cooling the engine water. The heat exchanger will be a separate unit. It will be installed in the pump or engine compartment with the control located on the pump operator's control panel. The exchanger will be plumbed to the master drain valve. 0014486
Not Required, Transfer Valve, Single
Stage Pump
0746508
Valve(s), Relief Intake, Trident Air
Max, Control Location
INTAKE RELIEF VALVE
One (
1 )
Trident Air Max intake relief valve(s) will be installed on the suction side of the pump preset at
125
psig
.
The relief valve will have a working range of
50 PSI to
350
PSI.
The outlet will terminate below the frame rails with a
2.50 " National Standard hose thread adapter
and will have a "do not cap" warning tag.
One (
1 ) adjustable air regulator and pressure indicating gauge will be located on a common bezel on the left side pump panel
to control the intake valve(s).
0721609
Controller, Pressure, Pierce LCD,
Custom Chassis
PIERCE PRESSURE CONTROLLER
A Pierce electronic pressure controller will be provided.
A pressure transducer will be installed in the discharge side of the water pump. The transducer continuously monitors pump pressure sending a signal to the electronic pressure controller.
The pressure controller can be used in two (
2 ) modes of operation, RPM mode and pressure
modes. The controller will be programmed to turn on/default to No Mode/Default Press Setting
mode.
In the RPM mode, the controller can be activated after vehicle parking brake has been set. When in this mode, the controller will maintain the set engine speed, regardless of engine load (within engine operation capabilities).
In the pressure mode, the controller can be activated after vehicle parking brake has been set.
When in this mode, the controller will automatically maintain the discharge pressure set by the operator (within the discharge capabilities of the pump and water supply) regardless of flow.
A
2.00 " diameter throttle control knob with no mechanical stops, a serrated grip, and a red idle push button in the center will be a integrated/part of the pressure controller. The throttle control knob will be programmed for
Clockwise
rotation to increase engine speed.
Individual LED indicators for ok to pump, throttle ready, pressure mode and rpm mode will be located on the pressure controller for easy viewing.
A pump cavitation protection feature will also provided which will return the engine to idle should the pump cavitate. Cavitation is sensed by the combination of pump pressure below 30 psi and
engine speed above
2000
rpm for more than five (
5 ) seconds.
Other safety features include recognition of low water and no water conditions with an automatic programmed response and a push button to return the engine to idle.
The pressure controller LCD screen will be
4.20 " in size with a minimum brightness of
750
nits.
The LCD screen and LED intensity will be automatically adjust for day and nighttime operation.
The LCD screen intensity can also be manually adjusted if needed.
The following information will be provided/displayed on the LCD screen - Engine RPM
Check engine and stop engine warning indicators
Engine oil pressure
Engine coolant temperature
Water pump transmission temperature
Fuel Level
Water tank level
Battery voltage
Operating mode (RPM or pressure)
Pressure or RPM setting
On screen messaging show diagnostic and warning messages as they occur. It will show apparatus information, stored data, and program options when selected by the operator. It will monitor inputs outputs and support audible and visual warning alarms for the following conditions -
High battery voltage
Low battery voltage/engine off
Low battery voltage/engine running
High water pump temperature
Low fuel
Low engine oil pressure
High engine coolant temperature
Water tank out of water (visual alarm only)
No engine response (visual alarm only)
The pressure controller will store the accumulated operating hours for the pump and engine.
These items are to be displayed within the pressure controller menu.
The pressure controller will include a USB port on the back of the controller for easy software upgrades if needed.
0072153
Primer, Trident, Air Prime, Air
Operated
PRIMING PUMP
The priming pump will be a Trident Emergency Products compressed air powered, high efficiency, multistage venturi based AirPrime System, conforming to standards outlined in the current edition of NFPA
1901
.
All wetted metallic parts of the priming system are to be of brass and stainless steel construction.
One (
1 ) priming control will open the priming valve and start the pump primer. 48 931
Bid #:
0780364
Manuals, Pump, (2) Total, Electronic
Copies
PUMP MANUALS
There will be a total of two (
2 ) pump manuals provided by the pump manufacturer and furnished with the apparatus. The manuals will be provided by the pump manufacturer in the form of two ( 2 )
electronic copies. Each manual will cover pump operation, maintenance, and parts. 0603129
Plumbing, Stainless Steel and Hose,
Single Stage Pump
PLUMBING, STAINLESS STEEL AND HOSE
All inlet and outlet lines will be plumbed with either stainless steel pipe, flexible polypropylene tubing or synthetic rubber hose reinforced with hi-tensile polyester braid. All hose's will be equipped with brass or stainless steel couplings. All stainless steel hard plumbing will be a minimum of a schedule
10 wall thickness.
Where vibration or chassis flexing may damage or loosen piping or where a coupling is required for servicing, the piping will be equipped with victaulic or rubber couplings.
Plumbing manifold bodies will be ductile cast iron or stainless steel.
All piping lines are to be drained through a master drain valve or will be equipped with individual drain valves. All drain lines will be extended with a hose to drain below the chassis frame.
All water carrying gauge lines will be of flexible polypropylene tubing.
All piping, hose and fittings will have a minimum of a
500
PSI hydrodynamic pressure rating.
0795135
Plumbing, Stainless Steel, w/Foam
System
FOAM SYSTEM PLUMBING
All piping that is in contact with the foam concentrate or foam/water solution will be stainless steel. The fittings will be stainless steel or brass. Cast iron pump manifolds will be allowed. 0004645
Inlets, 6.00" - 1250 GPM or Larger
Pump
MAIN PUMP INLETS
A
6.00 " pump manifold inlet will be provided on each side of the vehicle. The suction inlets will include removable die cast zinc screens that are designed to provide cathodic protection for the pump, thus reducing corrosion in the pump.
0742704
Valve, Jamesbury, w/Relief, RS Main
Inlet, 6", Elec, Elk Apex S, w/O-ride
INLET BUTTERFLY VALVE
One (
1 ) S/S Jamesbury high performance butterfly valve will be provided on the right side main pump inlet.
The
6.00 " inlet valve will be provided with a
Elkhart Model
40-20
built-in, adjustable pressure
relief valve preset at
125
psig
and a bleeder valve will be provided on the inlet side of the valve.
The valve will be controlled with an Elkhart Apex S electric valve controller provided on the pump operator's panel. The electric control must be of a true position feedback design, requiring no clutches in the motor or current limiting. The controller will have momentary open, close as well as programmable preset valve positions. The controller will provide position indication on a full color, backlit LCD display. It will have manual adjustment of the brightness as well as an auto dimming option.
A manual override hex nut will be provided directly on the inlet valve. Access to the manual override hex nut will be provided with a hole thru the right side pump panel. The hole in the left pump panel will allow the use of a speed wrench and/or ratchet with a socket to be used on the valve override hex nut if needed.
0730368
Valve, Ball Intake, TFT, AX Series
INLET VALVES WITH INTAKE RELIEF VALVE
There will be
One (
1 )
Task Force Tips (TFT) AX Series aluminum ball intake valve(s) provided at Left Side Main Inlet
.
The inlet connection will be
1 ST (
5.0 " Rigid Storz) with a cap
with a matching cap and the outlet
connection will be
NX (
6.0 " Threaded Swivel)
. There will be an eight-position adjustable
30 degree swiveling detent elbow on the inlet side of the ball intake valve.
The ball intake valve will be controlled with a(n)
standard crank on the right side
.
If ball intake valve is to be controlled with a manual handwheel, the handwheel will be controlled with a NFPA compliant slow-close hand wheel. A position indicator will be provided to allow for a quick visualization of the status of the valve in the open, closed or transition position.
If the ball intake valve is to be electrically controlled, the ball intake valve will be controlled by a remote panel-mounted push-button switch with LED lights for a quick visualization of the status of the valve in the open, closed or transition position. The push button switch will be mounted on the pump operator's panel.
The ball intake valve will be equipped with a
slip joint behind the panel
adjustable pressure relief
valve. The relief valve will have a working range of
90 PSI to
300
PSI.
A
3/4
" TFT bleeder/drain valve will be provided on the ball intake valve to exhaust excess air or water from the valve.
For corrosion protection the aluminum casting will have a hard coat anodized finish, with a powder coated internal and external finish. All the components facing the wet side of the valve will be constructed from stainless steel.
0004646
Cap, Main Pump Inlet, Long Handle,
NST, VLH
MAIN PUMP INLET CAP
The main pump inlets will have National Standard Threads with a long handle chrome cap.
The cap will be the Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0084610
Valves, Akron 8000 series- All
VALVES
All ball valves will be Akron® Brass. The Akron valves will be the 8000
series heavy-duty style
with a stainless steel ball and a simple two-seat design. No lubrication or regular maintenance is required on the valve.
Valves will have a
ten (
10 ) year
warranty.
49 931
Bid #:
0004686
Valve, Inlet(s) Recess Behind Panel,
Side Cntrl
The location of the valve for the
two (2) inlets
will be behind the pump panel.
0004700
Control, Inlet, at Valve
INLET CONTROL
The side auxiliary inlet(s) will incorporate a quarter-turn ball valve with the control located at the inlet valve. The valve operating mechanism will indicate the position of the valve. 0004660
Inlet (1), Left Side, 2.50"
LEFT SIDE INLET
There will be one (
1 ) auxiliary inlet with a
2.50 " valve at the left side pump panel, terminating with a
2.50 " (F) National Standard hose thread adapter.
The auxiliary inlet will be provided with a strainer, chrome swivel and plug. 0004680
Inlet, Right Side, 2.50"
RIGHT SIDE INLET
There will be one (
1 ) auxiliary inlet with a
2.50 " valve at the right side pump panel, terminating
with a
2.50 " (F) National Standard hose thread adapter.
The auxiliary inlet will be provided with a strainer, chrome swivel and plug. 0034720
Anode, Zinc, Pair, Pump Inlets
ANODE, INLET
A pair of sacrificial zinc anodes will be provided in the water pump inlets to protect the pump from corrosion.
0012635
Elbow, 30 Degree Side Inlet, 6" FNST
Swivel x 5" Storz w/Cap
ADAPTER, INLET
One (
1 ) adapter for the inlet
will be provided. The elbow adapter will be furnished for the right side
main pump inlet/s. The elbow/s will be
6.00 "" female NST swivel to
5.00 " Storz. A
5.00 " Storz
cap will be provided with the elbow.
0092569
No Rear Inlet (Large Dia) Requested
0064116
No Rear Inlet Actuation Required
0092696
Not Required, Cap, Rear Inlet
0009648
No Rear Intake Relief Valve Required
on Rear Inlet
0092568
No Rear Auxiliary Inlet Requested
0723049
Valve, .75" Bleeder, Aux. Side Inlet,
"T" Swing Handle
INLET BLEEDER VALVE
A
0.75 " bleeder valve will be provided for each side gated inlet.
The valves will be located behind the panel with a "T" swing style handle control extended to the outside of the panel.
The handles will be chrome plated and provide a visual indication of valve position. The swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage.
The water discharged by the bleeders will be routed below the chassis frame rails. 0014751
Tank to Pump, (1) 3.00" Valve, 3.00"
Plumbing, Reverse Linkage
TANK TO PUMP
The booster tank will be connected to the intake side of the pump with heavy duty piping and a quarter turn
3.00 " full flow line valve with the control remotely located at the operator's panel. The tank to pump line will run straight (no elbows) from the pump into the front face of the water tank and down into the tank sump. A rubber coupling will be included in this line to prevent damage from vibration or chassis flexing.
The control on the pump panel will be "in" when the valve is open and "out" when the valve is closed.
A check valve will be provided in the tank to pump supply line to prevent the possibility of "back filling" the water tank.
0004905
Outlet, Tank Fill, 1.50"
TANK REFILL
A
1.50 " combination tank refill and pump re-circulation line will be provided, using a quarter-turn full flow ball valve controlled from the pump operator's panel. 50 931
Bid #:
0062133
Control, Outlets, Manual, Pierce HW
if applicable
DISCHARGE OUTLET CONTROLS
The discharge outlets will incorporate a quarter-turn ball valve with the control located at the pump operator's panel. The valve operating mechanism will indicate the position of the valve.
If a handwheel control valve is used, the control will be a minimum of a
3.9 " diameter stainless
steel handwheel with a dial position indicator built in to the center of the handwheel.
Any
3.00 inch or larger discharge valve will be a slow-operating valve in accordance with NFPA
16.7.5.3 .
0004940
Outlet, Left Side, 2.50"
LEFT SIDE DISCHARGE OUTLETS
There will be
Two (
2 ) discharge outlets
with a
2.50 " valve on the left side of the apparatus,
terminating with a
2.50 " (M) National Standard hose thread adapter.
0005091
Elbow, Left Side Outlets, 45 Degree,
2.50" FNST x 2.50" MNST, VLH
LEFT SIDE OUTLET ELBOWS
The
2.50 " discharge outlets located on the left side pump panel will be furnished with a
2.50 " (F)
National Standard hose thread x
2.50 " (M) National Standard hose thread, chrome plated, 45 degree elbow.
The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0092570
Not Required, Outlets, Left Side
Additional
0035094
Not Required, Elbow, Left Side
Outlets, Additional
0004945
Outlet, Right Side, 2.50"
RIGHT SIDE DISCHARGE OUTLETS
There will be
One (
1 ) discharge outlet
with a
2.50 " valve on the right side of the apparatus,
terminating with a
2.50 " (M) National Standard hose thread adapter.
0025091
Elbow, Right Side Outlets, 45
Degree, 2.50" FNST x 2.50" MNST,
VLH
RIGHT SIDE OUTLET ELBOWS
The
2.50 " discharge outlets located on the right side pump panel will be furnished with a
2.50 " (F)
National Standard hose thread x
2.50 " (M) National Standard hose thread, chrome plated, 45 degree elbow.
The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0011668
Outlet, Right Side, 3" w/3" Plumbing,
Handwheel Control, (added)
There will be
One (
1 ) discharge outlet
with a
3.00 " valve on the right side of the apparatus,
terminating with a
3.00 " (M) National Standard hose thread adapter.
The outlet will be controlled by a handwheel control located at the pump operator's panel. An indicator will be provided to show the position of the valve. 0045097
Elbow, Right Side Outlets, 30
Degree, 3.00" FNST x 5.00" Storz
w/Cap, Additional
ADDITIONAL RIGHT SIDE OUTLET ELBOWS
The
3.00 " outlet will be furnished with a
30 degree,
3.00 " (F) National Standard hose thread x
5.00 " Storz elbow adapter with Storz cap.
0029137
Not Required, Outlet, Large Diameter
0007308
Not Required, Elbow, Large Diameter
Outlet
0092572
Not Required, Outlet, Front
0004995
Outlet, Rear, 2.50"
REAR DISCHARGE OUTLET
There will be
One (
1 ) discharge outlet
piped to the rear of the hose bed,
left side
, installed so
proper clearance is provided for spanner wrenches or adapters. Plumbing will consist of
2.50 "
piping along with a
2.50 " full flow ball valve with the control from the pump operator's panel. 0045091
Elbow, Rear Outlets, 45 Degree,
2.50" FNST x 2.50" MNST, VLH
REAR OUTLET ELBOWS
The
2.50 " discharge outlets located at the rear of the apparatus will be furnished with a
2.50 " (F)
National Standard hose thread x
2.50 " (M) National Standard hose thread, chrome plated, 45 degree elbow.
The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0092574
Not Required, Outlet, Rear,
Additional
51 931
Bid #:
0085695
Not Required, Elbow, Rear Outlets,
Large, Additional
0092573
Not Required, Outlet, Hose
Bed/Running Board Tray
0752097
Caps/Plugs for 1.00" to 3.00"
Discharges/Inlets, Chain
DISCHARGE CAPS/ INLET PLUGS
Chrome plated, rocker lug, caps with chain will be furnished for all discharge outlets
1.00 " thru
3.00 " in size, besides the pre-connected hose outlets.
Chrome plated, rocker lug, plugs with chain will be furnished for all auxiliary inlets
1.00 " thru
3.00 "
in size.
The caps and plugs will incorporate a thread design to automatically relieve stored pressure in the line when disconnected.
0723042
Valve, 0.75" Bleeder, Discharges, "T"
Swing Handle
OUTLET BLEEDER VALVE
A
0.75 " bleeder valve will be provided for each outlet
1.50 " or larger. Automatic drain valves are
acceptable with some outlets if deemed appropriate with the application.
The valves will be located behind the panel with a T swing style handle control extended to the outside of the side pump panel.
The handles will be chrome plated and provide a visual indication of valve position.
The T swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage.
Bleeders will be located at the bottom of the pump panel. They will be properly labeled identifying the discharge they are plumbed in to.
The water discharged by the bleeders will be routed below the chassis frame rails. 0091106
Outlet, 3.00" Deluge w/TFT Extend-a-
Gun XG18, Handwheel
DELUGE RISER
A
3.00 " deluge riser will be installed above the pump in such a manner that a monitor can be mounted and used effectively. Piping will be rigidly braced and installed securely so no movement develops when the line is charged. The riser will be gated and controlled at the pump operator's panel with a handwheel control.
TELESCOPIC PIPING
The deluge riser piping will include a
18.00 " Task Force Model XG
18 Extend-A-Gun extension.
This extension will be telescopic to allow the deluge gun to be raised
18.00 " increasing the range
of operation.
A position sensor will be provided on the telescopic piping that will activate the "do not move vehicle" light inside the cab when the monitor is in the raised position. 0543550
Monitor, TFT Crossfire XFC-42, (2)
2.5" Portable Base, Shaper, Quad
Stack Tips
MONITOR
A Task Force Crossfire Series XFC-
42 monitor package will be properly installed on the deluge riser. The monitor package will include a Crossfire monitor with a
10.00 " stream shaper and quad
stack tips.
A Safe-Tak portable base unit with two (
2 )
2.50 " inlets will be provided. The monitor will be
painted to match the body
.
0040423
Nozzle, TFT Master Stream 1250 M-
R, 1250 GPM, Manual
NOZZLE
A Task Force Tips Master Stream
1250
M-R nozzle will be provided.
0046857
Deluge Mount, For TFT Crossfire
Monitor, TFT Manual Extend-A-Gun
Only
The deluge riser Extend-a-Gun will have provisions for direct mounting a Task Force Tips CrossFire monitor.
0723726
Speedlay Module Not Required
0722432
Hose Restraint Not Required, No
Speedlay Module
0723395
Speedlays, Not Required
0723394
Speedlays, Not Required
52 931
Bid #:
0029167
Crosslays Sngl Sheet Unpainted,
(2+) 1.50", Std. Cap
CROSSLAY HOSE BEDS
Two (
2 ) crosslays
with
1.50 " outlets will be provided. Each bed to be capable of carrying 200
' of
1.75 " double jacketed hose and will be plumbed with
2.00 " i.d. pipe and gated with a
2.00 "
quarter turn ball valve.
Outlets to be equipped with a
1.50 " National Standard hose thread
90 degree swivel located in
the hose bed so that hose may be removed from either side of apparatus.
The crosslay controls will be at the pump operator's panel.
The center crosslay dividers will be fabricated of
0.25 " aluminum and will provide adjustment from
side to side. The divider will be unpainted with a brushed finish.
Vertical scuffplates constructed of stainless steel will be provided at the front and rear ends of the bed on each side of vehicle.
Crosslay bed flooring will consist of removable perforated brushed aluminum. 0090442
Crosslays Sngl Sheet Unpainted, (1)
2.50" Std Cap
2.50 " CROSSLAY HOSE BED
One (
1 ) crosslay with
2.50 " outlets will be provided. This bed to be capable of carrying 200
' of
2.50 " double jacketed hose and will be plumbed with
2.50 " i.d. pipe and gated with a
2.50 "
quarter turn ball valve.
Outlet to be equipped with a
2.50 " National Standard hose thread
90 degree swivel located in the
hose bed so that hose may be removed from either side of apparatus.
The crosslay control will be at the pump operator's panel.
When used in conjunction with other crosslay/speedlay/deadlay configurations, a center crosslay divider, when needed, will be fabricated of .
25 " aluminum and will provide adjustment from side to
side. The divider will be unpainted with a brushed finish. The remainder of the crosslay bed will be painted job color.
Stainless steel vertical scuffplates will be provided at hose bed ends (each side of vehicle).
Bottom of hose bed ends (each side) will also be equipped with a stainless steel scuffplate.
Crosslay bed flooring will consist of removable perforated brushed aluminum. 0500535
Not Required, Hose Restraint,
Crosslay
0029260
Not Required, Speedlays
0750536
Hose Restr, Spdly, Not Required, No
Spdly
0761095
4-Way Cover, Crosslay/Deadlay
Ends, 2" Web w/Velcro Bottom, Seat,
w/Orange Tail
CROSSLAY/DEADLAY COVER & NETTING
A hinged aluminum treadplate cover will be installed over the crosslay hose beds. It will include a latch at each end of the cover to hold it securely in place, a chrome grab handle at each end for opening and closing the cover and a foam rubber gasket where the cover comes into contact to a painted surface.
The ends will be made of
2 " nylon netting sewn into a box pattern with seat belt buckle(s) on top and
2 " Velcro straps with footman loops at the bottom will be provided on each end of the crosslay/deadlay compartments to secure the hose during travel.
There will be a
1 " orange pull strap added to each buckle.
0019853
Crosslays, 8.00" Lower Than
Standard - Control Zone w/9.00"
Raised PH
CROSSLAY
8.00 " LOWER THAN STANDARD
The crosslays will be lowered
8.00 " from standard.
0511256
Reel, Booster, Steel - Over Pump,
Right Side, NPSH Fitting
BOOSTER HOSE REEL
A Hannay electric rewind booster hose reel will be installed over the pump in a recessed open compartment on the right side of the apparatus.
The exterior finish of the reel will be
painted job color matching the lower body
.
A polished stainless steel roller and guide assembly will be mounted on the reel side of the apparatus.
Discharge control will be provided at the pump operator's panel. Plumbing to the reel will consist of
1.50 " Aeroquip hose and a
1.50 " valve.
The reel will include NPSH threaded couplings.
0025870
Switches, Reel Rewind - 1 Reel w/1
Stirrup & 1 Push
Reel motor will be protected from overload with a
50 amp automatic reset circuit breaker.
One (
1 ) foot actuated, stirrup type, electric rewind control (switches) will be installed on the reel side below the body. An additional push-button switch will be provided at the reel. 0018394
Hose, Booster - 150' of 1.00"/800
PSI, 1" NPSH Coupling
Booster hose,
1.00 " diameter and
150
feet, with chrome plated Barway, or equal couplings will be provided. The couplings will have
1 " NPSH threads.
Working pressure of the booster hose will be a minimum of 800
psi.
0017858
Capacity, Hose Reel 150' of 1"
Capacity of the hose reel will be 150 feet of 1.00" booster hose. 0007428
Nozzle for Booster Reel Not Req'd
53 931
Bid #:
0025260
Cutout for Reel Access, One,
w/Roller Assembly, w/Window
HOSEREEL ACCESS
A cutout will be provided in the side sheet next to the booster hose reel. This cutout will allow access to the hose and provide a window to view the reel. Stainless steel rollers with nylon bushings will be mounted horizontally and vertically around the cutout. 0046560
Manual, Override, Hose Reel
A manual rewind will be provided for the booster hose reel. 0745878
SP
Modify Hose Reel Payout Direction
and Wiring
MODIFY REEL PAYOUT.
Flip the plumbing neck
180
degrees and change the wiring connections.
0085328
Nozzle Cup, Zico w/Bracket
NOZZLE CUP AND BRACKET
A Zico nozzle cup and chrome plated mounting bracket will be provided for storage of the booster reel nozzle.
There will be
one (
1 )
provided. The nozzle cup(s) will have a
3-1/2
" inside diameter
and will be
located
passenger side cargo area side sheet centered below the booster reel cut out approx 9 to
12 " down just above the pump panel. Match Job
33716
.
0007827
Foam Sys, FoamPro 2002 (Single
Agent)
FOAM CONCENTRATE PROPORTIONING SYSTEM
A Hypro FoamPro®, Model
2002
, foam system will be provided as the means for the
proportioning of foam concentrate into the water stream. The FoamPro is an electronic, fully automatic, variable speed, direct injection, discharge side foam proportioning system.
This system will be a single agent system capable of handling Class A foam concentrates, as well as most Class B foam concentrates.
The foam system will be plumbed to
four (
4 ) discharges
. The discharges capable of dispensing
foam will be
both
1.5 " discharge, rear discharge, and hose reel
.
The foam proportioning system operation will be based on a direct measurement of water flows, and remain consistent within the specified flow and pressure. The system will be equipped with a digital electronic control display on the pump panel. Incorporated within the control display will be a microprocessor, which receives input from the system flow meter while also monitoring the foam concentrate pump output. The microprocessor will compare the values of the water flow versus the foam flow, to ensure the proportion rate is accurate.
One (
1 ) paddle wheel will be installed to monitor all foam discharges.
Push button control for the form proportioning rate will allow a ratio from . 1 percent to
3 percent in
.
1 percent increments.
The rated capacity of this system will be
166
gpm at
3 percent and
1000
gpm at .
5 percent.
A
5 gpm positive displacement foam pump will be powered by a 12 vdc electric motor.
One (
1 ) check valve will be installed in the plumbing to prevent foam from contaminating the water pump. The check valve will be approved by the foam system manufacturer. 0012126
Not Required, CAF Compressor
0802356
Foam Refill, Pump, Foam Pro,
Power-Fill
FOAM REFILL PUMP
A
12 v pump will be permanently mounted in the pump compartment. A male quick disconnect fitting will be provided on the
Left Pump Panel
and a pick-up wand with a
6 ' tube and mating
female fitting will be provided loose.
The control switch for the pump will be located on the pump panel adjacent to the quick disconnect fitting. The pump will be plumbed to the foam tank allowing the user to refill the foam tank from the ground.
0031896
Demonstration, Foam System, Dealer
Provided
0005447
Foam Cell, 30 Gallon, Not Reduce
Water
FOAM TANK
The foam tank will be an integral portion of the polypropylene water tank. The cell will have a capacity of
30 gallons of foam with the intended use of
Class A foam
. The foam cell will not
reduce the capacity of the water tank. The foam cell will have a screen in the fill dome and a breather in the lid.
0091036
Drain, 1.00" Foam Tank #1
FOAM TANK DRAIN
The foam tank drain will be a
1.00 " drain valve located inside the pump compartment accessible through a door on the right side pump panel.
0091079
Not Required, Foam Tank #2
0091112
Not Required, Foam Tank #2 Drain
54 931
Bid #:
0746447
Approval Dwg, All Pump Panel(s),
Includes Color And Label Tags
The following drawing(s) will be provided for approval by the customer. The drawing(s) will be made for up
Two (
02 ) Truck
apparatus and/or similar Pierce job number.
PUMP OPERATOR'S PANEL DRAWING
A detailed drawing to scale of the pump operator's panel will be provided for the customer to review. The drawing will include all of the gauges, controls, switching, etc.., located on the pump operator's panel. The customer will be allowed to make changes and/or mark-ups to this approval drawing. The fire apparatus manufacturer will make revisions (If needed) to the drawing per the customer changes and/or mark-ups as long as the changes are physically possible within a specific product line.
The finalized and signed customer approved pump operator's panel drawing will become part of the contract documents.
Due to the way drain(s), bleeder(s), operational/maintenance tag(s) and NFPA required warning tag(s) are placed on pump panel(s), these items will NOT be shown on any pump panel approval drawing(s). These item(s) will be placed on pump panel(s) at the fire apparatus manufacturer discretion.
REMAINING PUMP PANEL(S)
Detailed drawing(s) to scale of the remaining pump panel(s) will be provided for the customer to review. The drawing(s) will include all of the gauges, controls, switching, etc.., located on the pump panel(s). The customer will be allowed to make changes and/or mark-ups to these approval drawing(s). The fire apparatus manufacturer will make revisions (If needed) to the drawing(s) per the customer changes and/or mark-ups as long as the changes are physically possible within a specific product line.
The finalized and signed customer approved pump panel drawing(s) will become part of the contract documents.
Due to the way drain(s), bleeder(s), operational/maintenance tag(s) and NFPA required warning tag(s) are placed on pump panel(s), these items will NOT be shown on any pump panel approval drawing(s). These item(s) will be placed on pump panel(s) at the fire apparatus manufacturer discretion.
COLOR CODED TAGS
A detailed drawing/chart of the colors used on all of the inlet(s) and outlet(s) will be provided for the customer to review. The customer will be allowed to make changes and/or mark-ups to this approval drawing/chart. The fire apparatus manufacturer will make revisions (If needed) to the drawing per the customer changes and/or mark-ups as long as the changes are physically possible within a specific product line.
The finalized and signed customer approved drawing/chart of the colors will become part of the contract documents.
SPECIAL TEXT/VERBIAGE TAGS
A detailed drawing/chart of the text/verbiage used on all of the inlet(s) and outlet(s) will be provided for the customer to review. The customer will be allowed to make changes and/or mark- ups to this approval drawing/chart. The fire apparatus manufacturer will make revisions (If needed) to the drawing per the customer changes and/or mark-ups as long as the changes are physically possible within a specific product line.
The finalized and signed customer approved drawing/chart of the text/verbiage will become part of the contract documents.
0728887
SP
Pump Panel Configuration, Selected
Elsewhere
PUMP PANEL CONFIGURATION
The pump panel configuration will be neat and orderly.
0005525
Material, Pump Panels, Side Control
Brushed Stainless
PUMP AND GAUGE PANEL
The pump and gauge panels will be constructed of stainless steel with a brushed finish. A polished aluminum trim molding will be provided on both sides of the pump panel. 0721765
Panel, Pump Access - Right Side
Only, Side Control
PUMP ACCESS
Right Side Panel
The right side upper pump panel will be removable.
Panel Fastener
The removable panels will be secured with
chrome flush lift and turn latch
.
The left side pump panels will be attached with screws.
The right side lower pump panel (drain bank) will be attached with screws. 0005945
Light, Pump Compt
PUMP COMPARTMENT LIGHT
A pump compartment light will be provided inside the right side pump enclosure and accessible through a door on the pump panel.
A .
125
" weep hole will be provided in each light lens, preventing moisture retention. 0536401
Gauges, Engine, Included With
Pierce Pressure Controller
Engine monitoring graduated LED indicators will be incorporated with the pressure controller. 0005601
Throttle, Engine, Incl'd w/Press
Controller
0739224
Indicator Light @ Pump Panel,
Throttle Ready, Incl w/Pressure
Gov/Throttle,Green
THROTTLE READY GREEN INDICATOR LIGHT
There will be a green indicator light integrated with the pressure governor and/or engine throttle installed on the pump operators panel that is activated when the pump is in throttle ready mode. 55 931
Bid #:
0549333
Indicators, Engine, Included with
Pressure Controller
0737184
SP
Indicator Light, Pump Panel, Ok To
Pump, Green, LED
OK TO PUMP INDICATOR LIGHT - LED
There will be a green indicator LED light installed on the pump operators panel that is activated when the pump is in Ok To Pump mode.
0069390
Control, Air Horn At Pmp Pnl, Red
Button
AIR HORN BUTTON
An air horn control button will be provided at the pump operator's control panel. This button will be red in color and properly labeled and put within easy reach of the operator. 0066121
Drains, LS, Keep Area Under Main
Inlet Clear
DRAINS, LEFT SIDE
The drains on the left side pump panel will be located to keep the area under the main pump inlet clear for customer installed piston intake valve.
0777838
Speaker, Atkinson Dynamics ADSF-
25-Z , W/ Volume Control, Pmp Pnl
RADIO SPEAKER
A Atkinson Dynamics ADSF-
25 -Z, radio speaker will be provided and mounted at the pump panel. There will be a weatherproof off/on/volume control provided on the pump panel. Wiring will be provided from the control to the
drivers side pump panel, Match Job
33716
.
for the customer's
connection.
0044860
Test Port, Electronic, Pump RPM,
Waterous Pump
TEST PORT
An electronic pump RPM test port will be provided.
0005689
Gauges, 4.50" Master, Class 1, 30"-0
-600psi
VACUUM AND PRESSURE GAUGES
The pump vacuum and pressure gauges will be liquid filled and manufactured by Class 1 Incorporated ©.
The gauges will be a minimum of
4.50 " in diameter and will have white faces with black lettering, with a pressure range of
30.00 "-
0-600#
.
The pump pressure and vacuum gauges will be installed adjacent to each other at the pump operator's control panel.
Test port connections will be provided at the pump operator's panel. One will be connected to the intake side of the pump, and the other to the discharge manifold of the pump. They will have
0.25 in. standard pipe thread connections and polished stainless steel plugs. They will be marked with a label.
0005714
Gauge, 2.50" Pressure, Class 1, 0-
400psi
PRESSURE GAUGES
The individual "line" pressure gauges for the discharges will be Class 1 © interlube filled.
They will be
2.50 " in diameter and have white faces with black lettering.
Gauges will have a pressure range of
0-400#
.
The individual pressure gauge will be installed as close to the outlet control as practical. 0750526
Gauge, Water Level, Pierce, In
pressure Controller, Lt Driver
WATER LEVEL GAUGE
An electric water level gauge will be incorporated in the pressure controller that registers water level by means of
9 LEDs. They will be at
1/8
level increments with a tank empty LED. The LEDs
will be a bright type that is readable in sunlight, and have a full 180
-degree of clear viewing.
To further alert the pump operator, the gauge will have a warning flash when the tank volume is less than
25%
, and will have "Down Chasing LEDs when the tank is almost empty.
The level measurement will be ascertained by sensing the head pressure of the fluid in the tank or cell.
There will be a light driver module with this installation to power additional water level gauge(s) included on the apparatus.
0750438
Water Level Gauge, Wln PSTANK2,
LED 1-Light, 4-Level
WATER LEVEL GAUGE
There will be
two (
2 )
additional water level indicator(s), Whelen®, Model PSTANK 2 , LED module
with
chrome trim
, installed
one (
1 ) each side rearward of crew cab doors
.
This light module(s) will include four (
4 ) colored levels, and function similar to the water level indicator located at the operators panel:
First green module indicates a full water level
Second blue module indicates a water level above
3/4
full
Third amber module indicates a water level above
1/2
full
Last red module indicates a water level above
1/4
full and empty
Above
1/4
this light will be steady burning
At empty this light will be flashing
The flash rate will be determined by the main water level tank sensor.
This module will be activated when the
pump is in gear
.
56 931
Bid #:
0062992
Gauge, Foam Level, (1) Tank, Class
1, GAAAR 5lt
FOAM LEVEL GAUGE
An electronic foam level gauge will be provided on the operator's panel that registers foam level by means of five (
5 ) colored LED lights. The lights will be durable, ultra-bright five ( 5 ) LED design
viewable through
180
degrees. The foam level indicators will be as follows:
100
percent = Green
75 percent = Yellow
50 percent = Yellow
25 percent = Yellow
Refill = Red
The light will flash when the level drops below the given level indicator to provide an eighth of a tank indication. To further alert the pump operator, the lights will flash sequentially when the foam tank is empty.
The level measurement will be based on the sensing of head pressure of the fluid in the tank.
The display will be constructed of a solid plastic material with a chrome plated die cast bezel to reduce vibrations that can cause broken wires and loose electronic components. The encapsulated design will provide complete protection from foam and environmental elements. An industrial pressure transducer will be mounted to the outside of the tank. The display will be able to be calibrated in the field and will measure head pressure to accurately show the tank level. 0593161
Light Shield, S/S LED
LIGHT SHIELD
There will be a polished,
16 gauge stainless steel light shield installed over the pump operator's panel.
There will be
12 volt DC white LED lights installed under the stainless steel light shield to illuminate the controls, switches, essential instructions, gauges, and instruments necessary for the operation of the apparatus. These lights will be activated by the pump panel light switch.
Additional lights will be included every
18.00 " depending on the size of the pump house.
One (
1 ) pump panel light will come on when the pump is in ok to pump mode.
There will be a light activated above the pump panel light switch when the parking brake is set.
This is to afford the operator some illumination when first approaching the control panel. 0606694
Air Horns, (2) Hadley, 6" Round,
eTone, In Bumper
AIR HORN SYSTEM
Two (
2 ) Hadley®, eTone, chrome air horns will be recessed in the front bumper. The air horn system will be piped to the air brake system wet tank utilizing
0.38 " tubing. A pressure protection
valve will be installed to prevent the loss of air in the brake system. 0606834
Location, Air Horns, Bumper, Each
Side, Outside Frame, Inboard (Pos
#2 & #6)
Air Horn Location
The air horns will be located on each side of the bumper, just outside of the frame rails. 0757092
Control, Air Horn, Multi Select
Air Horn Control
The air horn(s) will be activated by the following:
0757080
Control, Air Horn, Ft Sw, RS
Right side foot switch
0757081
Control, Air Horn, Ft Sw, LS
Left side foot switch
0602730
Siren, Wln 295SLSA1, 100 or 200
Watt, Other Speaker, Non-NFPA
2016
ELECTRONIC SIREN
A Whelen, Model:
295
SLSA
1 , electronic siren with noise canceling microphone will be provided.
This siren to be active when the battery switch is on and that emergency master switch is on.
NFPA
1901
,
2016
edition, Section
13.9.1.1 requires the siren manufacturer to certify the siren as meeting the requirements of SAE J
1849
,
Emergency Vehicle Sirens
.
Per the fire department specification, the siren and siren speaker come from separate manufacturers and a certification is therefore invalid. The apparatus will be non compliant to NFPA
1901
standards at time of contract execution.
0510206
Location, Elect Siren, Recessed
Overhead In Console
Electronic siren head will be
recessed in the passenger side inside switch panel
.
0006145
Control, Elec Siren, Horn Ring, PS
Foot Sw
Siren will be actuated by a foot switch on the officer's side and by the horn button in the steering wheel. The driver will have the option to control the siren or the chassis horns from the horn button by means of a selector switch.
0601306
Speaker, (1) Wln, SA315P, w/Pierce
Polished Stainless Steel Grille, 100
watt
SPEAKER
There will be one (
1 ) Whelen®, Model SA
315
P, black nylon composite,
100
-watt, speaker with
through bumper mounting brackets and polished stainless steel grille provided. The speaker will be
connected to the siren amplifier
.
0601555
Location, Speaker, Frt Bumper,
Recessed, Left Side, Outside
Frame,Outbrd (Pos 7)
The speaker will be recessed in the left side of the front bumper, towards the outside. 57 931
Bid #:
0895310
Siren, Federal Q2B
AUXILIARY MECHANICAL SIREN
There will be a Federal Signal Model Q
2 B mechanical siren furnished and installed in the front of the apparatus.
The Q
2 B will be
chrome finish
.
The siren will have a
2 -gauge cable connected to a power solenoid that is connected by a 2 -
gauge cable ran battery direct to the primary chassis batteries and will be labeled Q 2 B+ at the
battery. The power solenoid will only be enabled when the emergency master switch is on.
The siren will have a
2 -gauge ground wire connected to the chassis battery stud. The cable will be labeled Q
2 B- at the battery.
0006097
Location of Siren, Recessed in
Bumper
The mechanical siren will be recessed in the front bumper on the right side
. The siren will be
properly supported using the bumper framework.
0748305
Control, Mech Siren, Multi Select
MECHANICAL SIREN CONTROL
The mechanical siren will be activated by the following:
0748280
Control Mech Siren, Horn Ring
Steering wheel horn ring with horn/siren selector switch. 0748281
Control Mech Siren, Ft Sw RS
Right side foot switch.
0748282
Control Mech Siren, Ft Sw LS
Left side foot switch.
0740391
Sw, Siren Brake, Momentary Chrome
Push Button, RS
A momentary chrome push button switch will be included in the right side dash panel to activate the siren brake.
0746353
Not Required, Warning Lights
Intensity
0780369
SP
Lightbar, Wln, Freedom IV-Q, 72",
RRRWR__Opt__RWRRR
FRONT ZONE UPPER WARNING LIGHTS
There will be one (
1 )
72.00 " Whelen® Freedom
™
IV lightbar mounted on the cab roof.
The lightbar will include the following:
One (
1 ) red flashing LED module in the driver's side end position.
One (
1 ) red flashing LED module in the driver's side front corner position.
One (
1 ) red flashing LED module in the driver's side first front position.
One (
1 ) white flashing LED module in the driver's side second front position.
One (
1 ) red flashing LED module in the driver's side third front position.
Open in the driver's side fourth front position.
Open in the driver's side fifth front position.
One (
1 )
795
LED traffic light controller sent to
national standard high priority
in the center
positions.
Open in the passenger's side fifth front position.
Open in the passenger's side fourth front position.
One (
1 ) red flashing LED module in the passenger's side third front position.
One (
1 ) white flashing LED module in the passenger's side second front position.
One (
1 ) red flashing LED module in the passenger's side first front position.
One (
1 ) red flashing LED module in the passenger's side front corner position.
One (
1 ) red flashing LED module in the passenger's side end position.
There will be
clear lenses included on the lightbar
.
The following switches may be installed in the cab on the switch panel to control the lightbar:
A switch to control the flashing LED modules.
the traffic light controller
by a cab switch with emergency master control
a driver's side momentary cab switch with no emergency master control to activate the traffic light controller
The white LEDs and the traffic light controller will be deactivated when the parking brake is applied.
The four (
4 ) red flashing LED modules in the front positions may be load managed when the parking brake is applied.
0605741
Lightbars, Wln, Freedom IV, 2-21.5",
RRRR RRRR
SIDE WARNING LIGHTS
There will be two (
2 )
21.50 " Whelen Freedom IV LED lightbars mounted on the roof, one ( 1 ) on
each side,
over the cab doors
.
Each lightbar will include the following:
One (
1 ) red flashing LED module in the outside rear corner position.
One (
1 ) red flashing LED module in the rear outside position.
One (
1 ) red flashing LED module in the front outside position.
One (
1 ) red flashing LED module in the outside front corner position.
There will be
clear lenses included on the lightbar
.
There will be a switch in the cab on the switch panel to control the lightbars.
These lights may be load managed when the parking brake is applied. 0016380
No Additional Lights Req'd, Side
Zone Upper
58 931
Bid #:
0899300
Lights, Front Zone, Wln M6** M6RS
M6RS M6**, Inside Steady Burn, 4lts
Q Bez
FRONT ZONE LOWER LIGHTS
There will be four (
4 ) Whelen®,
4.31 " high x
6.75 " wide x
1.37 " deep lights installed on the cab
face above the headlights, in a common bezel matching the one for the headlamps per the following.
One (
1 ) Model M
6 ** flashing light installed in the left side outside position. The left side outside
warning light to include red LEDs
.
One (
1 ) Model M
6 RS steady burning light installed in the left side inside position. The light will include red LEDs.
One (
1 ) Model M
6 RS steady burning light installed in the right side inside position. The light will include red LEDs.
One (
1 ) Model M
6 ** flashing light installed in the right side outside position. The right side outside
warning light to include red LEDs
.
The
lens color(s) to be clear
.
The
housing to be polished and the trim shall be chrome
.
There will be a switch in the cab on the switch panel to control the lights. 0653937
Flasher, Headlight Alternating
HEADLIGHT FLASHER
The high beam headlights will flash alternately between the left and right side.
There will be a switch installed in the cab on the switch panel to control the high beam flash. This switch will be live when the battery switch and the emergency master switches are on.
The flashing will automatically cancel when
the hi-beam headlight switch is activated
or when the
parking brake is set.
0747228
Lights, Side Zone Lower, Wln M6**,
M6**, M6**, 6Lts
SIDE ZONE LOWER LIGHTING
There will be six (
6 ) Whelen®, Model M
6 **,
4.31 " high x
6.75 " long x
1.37 " deep flashing LED
warning lights with
chrome trim
installed per the following:
Two (
2 ) lights located,
one (
1 ) each side on the front custom cab corner
. The
driver's side, side
front light to include red warning LEDs
and the
passenger's side, side front light to include red
warning LEDs
.
Two (
2 ) lights located,
one (
1 ) each side of cab rearward of crew cab doors
. The
driver's side,
side middle light to include red warning LEDs
and the
passenger's side, side middle light to
include red warning LEDs
.
Two (
2 ) lights located,
one (
1 ) each side above rear wheels
. The
driver's side, side rear light to
include red warning LEDs
and the
passenger's side, side rear light to include red warning LEDs .
The
warning light lens colors to be the same as the LEDs
.
There will be a switch in the cab on the switch panel to control the lights. 0564655
Lights, Rear Zn Lwr, Wln M6*C LED,
Clear Lens, For Tail Lt Housing
REAR ZONE LOWER LIGHTING
There will be two (
2 ) Whelen®, Model M
6 *C, LED flashing warning lights located at the rear of the apparatus.
The
driver's side rear light to be red
The
passenger's side rear light to be red
Both lights will include a lens that is clear.
There will be a switch located in the cab on the switch panel to control the lights. 0686562
Light, Rear Zone Up, Wln MCFLED2*
LED
REAR UPPER ZONE WARNING LIGHTS
There will be two (
2 ) Whelen, Model MCFLED
2 * LED warning beacons provided at the rear of the
truck, one (
1 ) each side.
The color of the lights will be:
The
rear upper light(s) on the driver's side to be red
.
The
rear upper light(s) on the passenger's side to be red
.
All lenses will be
clear
.
There will be a switch located in the cab on the switch panel to control the beacons. 0006551
Not Required, Lights, Rear Upper
Zone Blocking
0006615
Mtg, Rear Warn Lts, On Top of
Compt
The rear warning lights will be mounted on top of the compartmentation with all wiring totally enclosed. The rear deck lights will be mounted on the beavertails as high as possible. 0791463
Light, Traffic Directing, Wln TANF65,
34" Long LED
TRAFFIC DIRECTING LIGHT
There will be one (
1 ) Whelen® Model TANF
65 ,
34.00 " long x
2.37 " high x
2.37 " deep, amber LED
traffic directing light installed at the rear of the apparatus.
The Whelen Model TACTL
5 control head will be included with this installation.
The control head will be powered when the battery switch is on.
The
auxiliary flash not activated
.
0529858
Location, Traf Dir Lt, Recessed
Within Trdplt Step
This traffic directing light will be recessed within a treadplate step at the rear of the apparatus. 0530281
Location, Traf Dir Lt Controller,
Center Console in Sw Pnl
The traffic directing light controller will be located within the switch panel on the center console.
The controller will be within easy reach of the driver. 59 931
Bid #:
0015829
Circuit Breaker Panel with Inverter
CIRCUIT BREAKER PANEL
A circuit breaker panel will be installed in the
right side high on back wall of the driver side
compartment ahead of the rear axle (LS-
3 )
. A directory for each breaker will be provided adjacent to the circuit breaker panel. Identification of circuits will be done in a durable manner that provides years of service.
0006825
Reel, Elect Cable, Hannay, 1600, (3)
Wire
ELECTRIC CORD REEL
Furnished with the
120
volt AC electrical system will be a Hannay, Series
1600
, cord reel. The
reel will be provided with a
12 -volt electric rewind switch, that is guarded to prevent accidental operation and labeled for its intended use. The switch will be protected with a fuse and installed at a height not to exceed
72.00 " above the operators standing position.
The exterior finish of the reel(s) will be
painted
#269
gray from the reel manufacturer
.
A Nylatron guide to be provided to aid in the payout and loading of the reel . A ball stop will be
provided to prevent the cord from being wound on the reel.
A label will be provided in a readily visible location adjacent to the reel. The label will indicate current rating, current type, phase, voltage and total cable length.
A total of
one (
1 ) cord reel
will be provided
one (
1 ) in compartment RS
1 high and to the right
.
The cord reel will be configured with three (
3 ) conductors.
0006827
Cord, Electric, 12/3 Yellow, 3 Wire
CORD
Provided for electric distribution will be
one (
1 ) length installed on the reel
of
200
feet
of Carol
Super Vu-Tron II yellow
12/3
electrical cord.
A Hubbell L
5-15
,
15 amp,
120
volt, twist lock
connector body
will be installed on the end of the cord.
0815348
Receptacle Strip, 20A 120V 6-Place
36", 6" Centers, Plugmold, Interior
Cab, HW
POWER OUTLET STRIP
There will be
two (
2 )
Plugmold part number V
24 GB
306
,
36.00 " receptacle strip(s) with six (
6 )
20 amp
120
volt AC straight blade receptacles provided
one (
1 ) in each rear facing EMS cabinet
.
The strip(s) selected will be powered from the
shoreline to
120
volt AC power inverter internal
transfer sw
.
The strip(s) will be hard wired to the electrical system.
There will be a label installed near the strip(s) that state the following:
Line Voltage
Current Ratting (amps)
Phase
Frequency
0781579
Receptacle, 15/20A 120V 3-Pr 3-Wr,
NEMA 5-20R SB Dup, 1st, Interior
Cab
120
VOLT RECEPTACLE
There will be
two (
2 )
,
15/20
amp
120
volt AC three (
3 ) wire straight blade duplex receptacle(s)
with
interior stainless steel wall plate(s)
, installed
one (
1 ) in each rear facing EMS cabinet
. The
NEMA configuration for the receptacle(s) will be
5-20
R.
The receptacle(s) will be powered from the
shoreline to
120
volt AC power inverter internal
transfer sw
.
There will be a label installed near the receptacle(s) that state the following:
Line Voltage
Current Ratting (amps)
Phase
Frequency
0779722
Receptacle, 15/20A 120V 3-Pr 3-Wr,
NEMA 5-20R SB Dup, 1st, Interior
Body
120
VOLT RECEPTACLE
There will be
two (
2 )
,
15/20
amp
120
volt AC three (
3 ) wire straight blade duplex receptacle(s)
with
an interior stainless steel wall plate
, installed
LS
1 , exact location determined at pre-con
. The
NEMA configuration for the receptacle(s) will be
5-20
R.
The receptacle(s) will be powered from the
shoreline to
120
volt AC power inverter internal
transfer sw
.
There will be a label installed near the receptacle(s) that state the following:
Line Voltage
Current Ratting (amps)
Phase
Frequency
0519934
Not Required, Brand, Hydraulic Tool
System
0649736
Not Required, Hydraulic Tools
0007150
Bag of Nuts and Bolts
LOOSE EQUIPMENT
The following equipment will be furnished with the completed unit:
One (
1 ) bag
of chrome, stainless steel, or cadmium plated screws, nuts, bolts and washers, as used in the construction of the unit.
60 931
Bid #:
0766730
Speed Wrench, Electric Valve
Override
SPEED WRECH, ELECTRIC VALVE OVERRIDE
A one piece speed wrench will be provided in loose equipment for manually overriding the electric valve(s) on the truck. The speed wrench will have sockets welded on each end for overriding the valve(s).
0602516
NFPA Required Loose Equipment,
Pumper, NFPA 2016, Provided by
Fire Department
NFPA REQUIRED LOOSE EQUIPMENT PROVIDED BY FIRE DEPARTMENT The following loose equipment as outlined in NFPA
1901
,
2016
edition, section
5.9.3 and
5.9.4 will be provided by the fire department.
800
ft (
60 m) of
2.50 " (
65 mm) or larger fire hose.
400
ft (
120
m) of
1.50 " (
38 mm),
1.75 " (
45 mm), or
2.00 " (
52 mm) fire hose.
One (
1 ) handline nozzle,
200
gpm (
750
L/min) minimum.
Two (
2 ) handline nozzles,
95 gpm (
360
L/min) minimum.
One (
1 ) smoothbore of combination nozzle with
2.50 " shutoff that flows a minimum of
250
gpm.
One (
1 ) SCBA complying with NFPA
1981
for each assigned seating position, but not fewer than
four (
4 ), mounted in brackets fastened to the apparatus or stored in containers supplied by the SCBA manufacturer.
One (
1 ) spare SCBA cylinder for each SCBA carried, each mounted in a bracket fastened to the apparatus or stored in a specially designed storage space(s).
One (
1 ) first aid kit.
Four (
4 ) combination spanner wrenches.
Two (
2 ) hydrant wrenches.
One (
1 ) double female
2.50 " (
65 mm) adapter with National Hose threads.
One (
1 ) double male
2.50 " (
65 mm) adapter with National Hose threads.
One (
1 ) rubber mallet, for use on suction hose connections.
Two (
2 ) salvage covers each a minimum size of
12 ft x
14 ft (
3.7 m x
4.3 m).
One (
1 ) traffic vest for each seating position, each vest to comply with ANSI/ISEA 207
,
Standard
for High Visibility Public Safety Vests
, and have a five-point breakaway feature that includes two (
2 ) at the shoulders, two (
2 ) at the sides, and one (
1 ) at the front.
Five (
5 ) fluorescent orange traffic cones not less than
28.00 " (
711
mm) in height, each equipped
with a
6.00 " (
152
mm) retro-reflective white band no more than
4.00 " (
152
mm) from the top of
the cone, and an additional
4.00 " (
102
mm) retro-reflective white band
2.00 " (
51 mm) below the
6.00 " (
152
mm) band.
Five (
5 ) illuminated warning devices such as highway flares, unless the five ( 5 ) fluorescent
orange traffic cones have illuminating capabilities.
One (
1 ) automatic external defibrillator (AED).
Four (
4 ) ladder belts meeting the requirements of NFPA
1983
,
Standard on Fire Service
Life
Safety Rope and System Components
(if equipped with an aerial device).
If the supply hose carried does not use sexless couplings, an additional double female adapter and double male adapter, sized to fit the supply hose carried, will be carried mounted in brackets fastened to the apparatus.
If none of the pump intakes are valved, a hose appliance that is equipped with one or more gated intakes with female swivel connection(s) compatible with the supply hose used on one side and a swivel connection with pump intake threads on the other side will be carried. Any intake connection larger than
3.00 " (
75 mm) will include a pressure relief device that meets the requirements of
16.6.6 .
If the apparatus does not have a
2.50 " National Hose (NH) intake, an adapter from
2.50 " NH
female to a pump intake will be carried, mounted in a bracket fastened to the apparatus if not already mounted directly to the intake.
If the supply hose carried has other than
2.50 " National Hose (NH) threads, adapters will be
carried to allow feeding the supply hose from a
2.50 " NH thread male discharge and to allow the
hose to connect to a
2.50 " NH female intake, mounted in brackets fastened to the apparatus if not already mounted directly to the discharge or intake.
0519913
Not Required, Soft Suction Hose
SOFT SUCTION HOSE
There will be no soft suction hose provided.
0067023
Strainer, 2.50"
- One (1) - 2.50" National Standard hose thread barrel strainer, chrome plated 0602538
Extinguisher, Dry Chemical, Pumper
NFPA 2016 Class, Provided by Fire
Department
DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
NFPA
1901
,
2016
edition, section
5.9.4 requires one (
1 ) approved dry chemical portable fire
extinguisher with a minimum
80 -B:C rating mounted in a bracket fastened to the apparatus.
The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0602360
Extinguisher, 2.5 Gal. Pressurized
Water, Pumper NFPA 2016,Provided
by Fire Dept
WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
NFPA
1901
,
2016
edition, section
5.9.4 requires one (
1 )
2.5 gallon or larger water extinguisher
mounted in a bracket fastened to the apparatus.
The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0602679
Axe, Flathead, Pumper NFPA 2016
Classification, Provided by Fire
Department
FLATHEAD AXE PROVIDED BY FIRE DEPARTMENT
NFPA
1901
,
2016
edition, Section
5.9.4 requires one (
1 ) flathead axe mounted in a bracket
fastened to the apparatus.
The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe.
61 931
Bid #:
0602667
Axe, Pickhead, Pumper NFPA 2016
Classification, Provided by Fire
Department
PICKHEAD AXE PROVIDED BY FIRE DEPARTMENT
NFPA
1901
,
2016
edition, Section
5.9.4 requires one (
1 ) pickhead axe mounted in a bracket
fastened to the apparatus.
The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe.
0741569
Paint Process / Environmental
Requirements, Appleton
PAINT PROCESS
The exterior custom cab and body painting procedure will consist of a seven ( 7 ) step finishing
process as follows:
Manual Surface Preparation
- All exposed metal surfaces on the custom cab and body will be thoroughly cleaned and prepared for painting. Imperfections on the exterior surfaces will be removed and sanded to a smooth finish. Exterior seams will be sealed before painting. Exterior surfaces that will not be painted include; chrome plating, polished stainless steel, anodized aluminum and bright aluminum treadplate.
Chemical Cleaning and Pretreatment
- All surfaces will be chemically cleaned to remove dirt, oil, grease, and metal oxides to ensure the subsequent coatings bond well. The aluminum surfaces will be properly cleaned and treated using a high pressure, high temperature 4 step Acid Etch
process. The steel and stainless surfaces will be properly cleaned and treated using a high temperature
3 step process specifically designed for steel or stainless. The chemical treatment converts the metal surface to a passive condition to help prevent corrosion.
Surfacer Primer
- The Surfacer Primer will be applied to a chemically treated metal surface to provide a strong corrosion protective basecoat. A minimum thickness of 2 mils of Surfacer Primer
is applied to surfaces that require a Critical aesthetic finish. The Surfacer Primer is a two- component high solids urethane that has excellent sanding properties and an extra smooth finish when sanded.
Finish Sanding
- The Surfacer Primer will be sanded with a fine grit abrasive to achieve an ultra- smooth finish. This sanding process is critical to produce the smooth mirror like finish in the topcoat.
Sealer Primer
- The Sealer Primer is applied prior to the Basecoat in all areas that have not been previously primed with the Surfacer Primer. The Sealer Primer is a two-component high solids urethane that goes on smooth and provides excellent gloss hold out when topcoated.
Base
coat Paint
- Two coats of a high performance, two component high solids polyurethane basecoat will be applied. The Basecoat will be applied to a thickness that will achieve the proper color match. The Basecoat will be used in conjunction with a urethane clear coat to provide protection from the environment.
Clear Coat
- Two (
2 ) coats of Clear Coat will be applied over the Basecoat color. The Clear Coat is a two-component high solids urethane that provides superior gloss and durability to the exterior surfaces. Lap style and roll-up doors will be Clear Coated to match the body. Paint warranty for the roll-up doors will be provided by the roll-up door manufacturer.
After the cab and body are painted, the color will be verified to make sure that it matches the color standard. Electronic color measuring equipment will be used to compare the color sample to the color standard entered into the computer. Color specifications will be used to determine the color match. A Delta E reading will be used to determine a good color match within each family color.
All removable items such as brackets, compartment doors, door hinges, and trim will be removed and painted separately if required, to ensure paint behind all mounted items. Body assemblies that cannot be finish painted after assembly will be finish painted before assembly.
The paint finish quality levels for critical areas of the apparatus (cab front and sides, body sides and doors, and boom lettering panels) are to meet or exceed Cadillac/General Motors GMW
15777
global paint requirements. Orange peel levels are to meet or exceed the #6
A.C.T.standard in critical areas. The manufacture's written paint standards will be available upon request.
Environmental Impact
Contractor will meet or exceed all current state regulations concerning paint operations. Pollution control will include measures to protect the atmosphere, water and soil. Controls will include the following conditions:
Topcoats and primers will be chrome and lead free.
Metal treatment chemicals will be chrome free. The wastewater generated in the metal treatment process will be treated on-site to remove any other heavy metals.
Particulate emission collection from sanding operations will have a
99.99 percent efficiency
factor.
Particulate emissions from painting operations will be collected by a dry filter or water wash process. If the dry filter is used, it will have an efficiency rating of 98 percent. Water wash
systems will be
99.97 percent efficient
Water from water wash booths will be reused. Solids will be removed on a continual basis to keep the water clean.
Paint wastes are disposed of in an environmentally safe manner.
Empty metal paint containers will be recycled to recover the metal.
Solvents used in clean-up operations will be recycled on-site or sent off-site for distillation and returned for reuse.
Additionally, the finished apparatus will not be manufactured with or contain products that have ozone depleting substances. Contractor will, upon demand, present evidence that the manufacturing facility meets the above conditions and that it is in compliance with his state EPA rules and regulations.
0709567
Paint, Single Color, Enforcer
CAB PAINT
The cab will be painted
#80
red
.
0709845
Paint, Single Color, Body
BODY PAINT
The body will be
painted to match the single cab paint color
.
62 931
Bid #:
0646901
Paint Chassis Frame Assy, With
Liner, E-Coat, Standard
PAINT CHASSIS FRAME ASSEMBLY
The chassis frame assembly will be finished with
a single system black top coat
before the
installation of the cab and body, and before installation of the engine and transmission assembly, air brake lines, electrical wire harnesses, etc.
Components that are included with the chassis frame assembly that will be painted are:
Frame rails
Frame liners
Cross members
Axles
Suspensions
Steering gear
Battery boxes
Bumper extension weldment
Frame extensions
Body mounting angles
Rear Body support substructure (front and rear)
Pump house substructure
Air tanks
Steel fuel tank
Castings
Individual piece parts used in chassis and body assembly Components treated with epoxy E-coat protection prior to paint:
Two (
2 ) C-channel frame rails
Two (
2 ) frame liners
The E-coat process will meet the technical properties shown. 0693797
No Paint Required, Aluminum Front
Wheels
0693792
No Paint Required, Aluminum Rear
Wheels
0733739
Paint, Axle Hubs
AXLE HUB PAINT
All axle hubs will be painted
to match primary job color
.
0086770
Paint, 120V Air Conditioner Cover to
Match Roof
PAINTED AIR CONDITIONING COVER
The cover of the
120
volt air conditioning unit will be painted to match the color of the cab roof. 0007230
Compartment, Painted, Spatter Gray
COMPARTMENT INTERIOR PAINT
The interior of all compartments will be painted with a gray spatter finish for ease of cleaning and to make it easier to touch up scratches and nicks.
0544129
Reflective Band, 1"-6"-1"
REFLECTIVE STRIPES
Three (
3 ) reflective stripes will be provided across the front of the vehicle and along the sides of the body. The reflective band will consist of a
1.00 "
white
stripe at the top with a
1.00 " gap then a
6.00 "
gold
stripe with a
1.00 " gap and a
1.00 "
white
stripe on the bottom.
0007356
Reflective across Cab Face
The reflective band provided on the cab face will be at the headlight level. 0536954
Stripe, Chevron, Rear, Diamond
Grade, Pumper
REAR CHEVRON STRIPING
There will be alternating chevron striping located on the rear-facing vertical surface of the apparatus. The rear surface, excluding the rear compartment door, will be covered.
The colors will be red and
fluorescent yellow green
diamond grade.
Each stripe will be
6.00 " in width.
This will meet the requirements of the current edition of NFPA 1901
, which states that
50%
of the
rear surface will be covered with chevron striping.
0665144
Stripe, Reflective, Chevron, Cab and
Crew Cab Door Edge, Diamond
Grade
CHEVRON STRIPING ON CAB AND CREW CAB DOOR EDGE
There will be alternating chevron striping located on the inside of each cab and crew cab door edge. The design will be either DOT pattern or standard chevron design. Width will be determined by available space. The striping will consist of the following colors:
The first color will Ibe
red diamond grade
The second color will be
fluorescent yellow green diamond grade
0027341
Jog, In Reflective Stripe, Single or
Multiple
JOG(S) IN REFLECTIVE BAND
The reflective band located on each side of the apparatus body will contain one (
1 )
jog(s) and will
be angled at approximately a
45 degrees when installed.
0017359
Stripe, Black Outline, Vinyl on
Reflective Band
REFLECTIVE STRIPE OUTLINE
A black outline will be applied on the top and the bottom of the reflective band. There will be three
(
3 )
set of outline stripes required.
63 931
Bid #:
0065687
Stripe, Reflective, Cab Doors Interior
CAB DOOR REFLECTIVE STRIPE
A
6.00 " x
16.00 "
black
reflective stripe will be provided across the interior of each cab door. The stripe will be located approximately
1.00 " up from the bottom, on the door panel.
This stripe will meet the NFPA
1901
requirement.
0067298
Stripe, Gold Leaf, Across Cab Face
CAB FACE STRIPE
There will be a genuine gold leaf stripe across the face of the cab. 0680372
Stripe, Gold Leaf, Cab Sides, IPO
Chrome Molding
CAB STRIPE
There will be a genuine gold leaf stripe provided on both sides of the cab in place of the chrome molding.
0007280
Stripe, Gold Leaf, Corner, (Cab)
CAB FACE STRIPE
There will be a genuine gold leaf striped corner on each front corner of the cab. 0027372
Lettering Specifications, (GOLD
STAR Process)
LETTERING
The lettering will be totally encapsulated between two ( 2 ) layers of clear vinyl.
0686432
Lettering, Gold Leaf, 3.00", Each
LETTERING
There will be genuine gold leaf lettering,
3.00 " high, with
outline and shade
provided. There will
be
25 letters
provided.
0686010
Lettering, Reflective, 6.00", (21-40)
LETTERING
Twenty-one (
21 ) to forty (
40 ) reflective lettering,
6.00 " high, with
outline and shade
will be
provided.
0686229
Lettering, Gold Leaf, 6.00", Each
LETTERING
There will be genuine gold leaf lettering,
6.00 " high, with
outline and shade
provided. There will
be
four (
4 ) letters
provided.
0645076
Plate, Painted Alum. for
Lettering/Numerals
PAINTED PLATE(S) FOR LETTERING/NUMERALS
There will be
two (
2 )
painted aluminum plate(s) provided for department lettering. They will be mounted
Located at rear of truck. Match Job
33716
and will be
8 "H X
15 "W plate
in size.
0022652
Emblem, Maltese Cross, Gold Leaf,
15"-17", Pair
MALTESE CROSS INSTALLATION
There will be
one (
1 )
pair of maltese crosses, comprised of genuine gold leaf material, provided and installed
match emblem designed for job
33716
and place on cab door
.
0772003
Manual, Fire Apparatus Parts, USB
Flash Drive, Custom
FIRE APPARATUS PARTS MANUAL
There will be
one (
1 )
custom parts manual(s) in USB flash drive format for the complete fire apparatus provided.
The manual(s) will contain the following:
Job number
Part numbers with full descriptions
Table of contents
Parts section sorted in functional groups reflecting a major system, component, or assembly Parts section sorted in alphabetical order
Instructions on how to locate parts
Each manual will be specifically written for the chassis and body model being purchased. It will not be a generic manual for a multitude of different chassis and bodies.
Service Parts Internet Site
The service parts information included in these manuals are also available on the Pierce website.
The website offers additional functions and features not contained in this manual, such as digital photographs and line drawings of select items. The website also features electronic search tools to assist in locating parts quickly.
64 931
Bid #:
0772037
Manual, Chassis Service, USB Flash
Drive, Custom
CHASSIS SERVICE MANUALS
There will be
one (
1 )
chassis service manuals on USB flash drives containing parts and service information on major components provided with the completed unit.
The manual will contain the following sections:
Job number
Table of contents
Troubleshooting
Front Axle/Suspension
Brakes
Engine
Tires
Wheels
Cab
Electrical, DC
Air Systems
Plumbing
Appendix
The manual will be specifically written for the chassis model being purchased. It will not be a generic manual for a multitude of different chassis and bodies. 0773381
Manual, Chassis Operation, (1) USB
Flash Drive, Custom
CHASSIS OPERATION MANUAL
The chassis operation manual will be provided on one (
1 ) USB flash drive.
0030008
Warranty, Basic, 1 Year, Apparatus,
WA0008
ONE (
1 ) YEAR MATERIAL AND WORKMANSHIP
A Pierce basic apparatus limited warranty certificate, WA 0008
, is included with this proposal.
0735523
Warranty, Engine, Paccar MX13, 5
Year
ENGINE WARRANTY
A Paccar five (
5 ) year
limited engine warranty will be provided. A limited warranty certificate, XX, is included with this proposal.
0684953
Warranty, Steering Gear, Sheppard
M110, 3 Year WA0201
STEERING GEAR WARRANTY
A Sheppard
three (
3 ) year
limited steering gear warranty will be provided. A copy of the warranty certificate will be submitted with the bid package.
0596017
Warranty, Frame, 50 Year, Custom
Chassis, WA0013
FIFTY (
50 ) YEAR STRUCTURAL INTEGRITY
The Pierce custom chassis frame limited warranty certificate, WA 0013
, is included with this
proposal.
0595698
Warranty, Axle, 3 Year, TAK-4,
WA0050
FRONT AXLE THREE (
3 ) YEAR MATERIAL AND WORKMANSHIP WARRANTY
The Pierce TAK-
4 suspension limited warranty certificate, WA
0050
, is included with this proposal.
0733306
Warranty, Single Axle, 5 Year,
Meritor, General Service, WA0384
SINGLE REAR AXLE FIVE (
5 ) YEAR MATERIAL AND WORKMANSHIP WARRANTY
A Meritor
™
Axle
5 year limited warranty will be provided.
0652758
Warranty, ABS Brake System, 3
Year, Meritor Wabco, WA0232
ABS BRAKE SYSTEM THREE (
3 ) YEAR MATERIAL AND WORKMANSHIP
WARRANTY
A Meritor Wabco
™
ABS brake system limited warranty certificate, WA
0232
, is included with this
proposal.
0019914
Warranty, Structure, 10 Year, Custom
Cab, WA0012
TEN (
10 ) YEAR STRUCTURAL INTEGRITY
The Pierce custom cab limited warranty certificate, WA
0012
, is included with this proposal.
0744240
Warranty, Paint, 10 Year, Cab, Pro-
Rate, WA0055
TEN (
10 ) YEAR PRO-RATED PAINT AND CORROSION
A Pierce cab limited pro-rated paint warranty certificate, WA 0055
, is included with this proposal.
0524627
Warranty, Electronics, 5 Year, MUX,
WA0014
FIVE (
5 ) YEAR MATERIAL AND WORKMANSHIP
The Pierce Command Zone electronics limited warranty certificate, WA 0014
, is included with this
proposal.
0695416
Warranty, Pierce Camera System,
WA0188
CAMERA SYSTEM WARRANTY
A Pierce fifty four (
54 ) month
warranty will be provided for the camera system
.
0708760
Warranty, Not Applicable, LED Strip
Lights
COMPARTMENT LIGHT WARRANTY
The compartment lights will not offer an extended warranty. 65 931
Bid #:
0046369
Warranty, 5-year EVS Transmission,
Standard Custom, WA0187
TRANSMISSION WARRANTY
The transmission will have a
five (
5 ) year/unlimited mileage
warranty covering
100
percent
parts and labor. The warranty will be provided by Allison Transmission.
Note: The transmission cooler is not covered under any extended warranty you may be getting on your Allison Transmission. Please review your Allison Transmission warranty for coverage limitations.
0685945
Warranty, Transmission Cooler,
WA0216
TRANSMISSION COOLER WARRANTY
The transmission cooler will carry a five (
5 ) year parts and labor warranty (exclusive to the
transmission cooler). In addition, a collateral damage warranty will also be in effect for the first three (
3 ) years of the warranty coverage and will not exceed
$10,000
per occurrence. A copy of
the warranty certificate will be submitted with the bid package. 0688798
Warranty, Water Tank, Lifetime, UPF,
Poly Tank, WA0195
WATER TANK WARRANTY
A UPF poly water tank limited warranty certificate, WA
0195
, is included with this proposal.
0596025
Warranty, Structure, 10 Year, Body,
WA0009
TEN (
10 ) YEAR STRUCTURAL INTEGRITY
The Pierce apparatus body limited warranty certificate, WA 0009
, is included with this proposal.
0693127
Warranty, Gortite, Roll-up Door, 6
Year, WA0190
ROLL UP DOOR MATERIAL AND WORKMANSHIP WARRANTY
A Gortite roll-up door limited warranty will be provided. The mechanical components of the roll-up door will be warranted against defects in material and workmanship for the lifetime of the vehicle.
A
six (
6 ) year
limited warranty will be provided on painted and satin roll up doors.
The limited warranty certificate, WA
0190
, is included with this proposal.
0734463
Warranty, Pump, Waterous, 7 Year
Parts, WA0382
PUMP WARRANTY
The Waterous pump will be provided with a Seven (
7 ) year
material and workmanship limited
warranty.
A copy of the warranty certificate will be submitted with the bid package (no exception). 0648675
Warranty, 10 Year S/S Pumbing,
WA0035
TEN (
10 ) YEAR PUMP PLUMBING WARRANTY
The Pierce apparatus plumbing limited warranty certificate, WA 0035
, is included with this
proposal.
0641372
Warranty, Foam System, Not
Available
0595820
Warranty, Paint, 10 Year, Body, Pro-
Rate, WA0057
TEN (
10 ) YEAR PRO-RATED PAINT AND CORROSION
A Pierce body limited pro-rated paint warranty certificate, WA 0057
, is included with this proposal.
0595421
Warranty, Goldstar, 3 Year,
Apparatus, WA0018
THREE (
3 ) YEAR MATERIAL AND WORKMANSHIP
The Pierce Goldstar gold leaf lamination limited warranty limited warranty certificate, WA 0018
, is
included with this proposal.
0683627
Certification, Vehicle Stability,
CD0156
VEHICLE STABILITY CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the apparatus complies with NFPA
1901
, current edition, section
4.13 , Vehicle Stability. The certification will be provided at the time of bid.
0808565
Certification, Engine Installation, Enf,
Paccar MX, 2027
ENGINE INSTALLATION CERTIFICATION
The fire apparatus manufacturer will provide a certification, along with a letter from the engine manufacturer stating they approve of the engine installation in the bidder's chassis. The certification will be provided at the time of delivery. 0686786
Certification, Power Steering,
CD0098
POWER STEERING CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the power steering system as installed meets the requirements of the component supplier. The certification will be provided at the time of bid.
66 931
Bid #:
0892691
Certification, Cab Integrity, Saber
FR/Enforcer, CD0189
CAB INTEGRITY CERTIFICATION
The fire apparatus manufacturer will provide a cab crash test certification with this proposal. The certification will state that a specimen representing the substantial structural configuration of the cab has been tested and certified by an independent third party test facility. Testing events will be documented with photographs, real-time and high-speed video, vehicle accelerometers, cart accelerometers, and a laser speed trap. The fire apparatus manufacturer will provide a state licensed professional engineer to witness and certify all testing events. Testing will meet or exceed the requirements below:
SAE J
2422
Cab Roof Strength Evaluation - Quasi-Static Loading Heavy Trucks.
European Occupant Protection Standard ECE Regulation No. 29 .
SAE J
2420
COE Frontal Strength Evaluation - Dynamic Loading Heavy Trucks.
Side Impact
The cab will be subjected to dynamic preload where a
14,320
-lb moving barrier is slammed into
the side of the cab at
5.50 mph, striking with an impact of
13,000
ft-lb of force. This test is part of
the SAE J
2422
test procedure and more closely represents the forces a cab will see in a rollover incident.
Frontal Impact
The same cab will withstand a frontal impact of
32,600
ft-lb of force using a moving barrier in
accordance with SAE J
2420
.
Additional Frontal Impact
The same cab will withstand a frontal impact of
65,098
ft-lb of force using a moving barrier.
(Twice the force required by SAE J
2420
)
Roof Crush
The cab will be subjected to a roof crush force of
22,500
lb. This value meets the ECE
29 criteria,
and is equivalent to the front axle rating up to a maximum of ten ( 10 ) metric tons.
Additional Roof Crush
The same cab will be subjected to a roof crush force of 110,000
lbs. (Four and a half times the
load criteria of ECE
29 )
The same cab will withstand all tests without any measurable intrusion into the survival space of the occupant area.
There will be no exception to any portion of the cab integrity certification. Nonconformance will lead to immediate rejection of bid.
0631973
Certification, Cab Door Durability,
Saber FR/Enforcer, CD0137
CAB DOOR DURABILITY CERTIFICATION
Robust cab doors help protect occupants. Cab doors will survive a 200,000
cycle door slam test
where the slamming force exceeds
20 G's of deceleration. The bidder will certify that the sample doors similar to those provided on the apparatus have been tested and have met these criteria without structural damage, latch malfunction, or significant component wear. 0631978
Certification, Windshield Wiper
Durability, Saber FR/Enforcer,
CD0132
WINDSHIELD WIPER DURABILITY CERTIFICATION
Visibility during inclement weather is essential to safe apparatus performance. Windshield wipers will survive a
3 million cycle durability test in accordance with section
6.2 of SAE J
198
Windshield
Wiper Systems - Trucks, Buses and Multipurpose Vehicles.
The bidder will certify that the wiper
system design has been tested and that the wiper system has met these criteria. 0631974
Certification, Electric Window
Durability, Saber FR/Enforcer,
CD0133
ELECTRIC WINDOW DURABILITY CERTIFICATION
Cab window roll-up systems can cause maintenance problems if not designed for long service life. The window regulator design will complete
30,000
complete up-down cycles and still function
normally when finished. The bidder will certify that sample doors and windows similar to those provided on the apparatus have been tested and have met these criteria without malfunction or significant component wear.
0631977
Certification, Seat Belt Anchors and
Mounting, Saber FR/Enforcer,
CD0134
SEAT BELT ANCHOR STRENGTH
Seat belt attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat belt anchor design will withstand 3000
lb of pull on both
the lap and shoulder belt in accordance with FMVSS
571.210
Seat Belt Assembly Anchorages.
The bidder will certify that each anchor design was pull tested to the required force and met the appropriate criteria.
SEAT MOUNTING STRENGTH
Seat attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat mounting design will be tested to withstand 20 G's of force in
accordance with FMVSS
571.207
Seating Systems. The bidder will certify, at time of delivery, that each seat mount and cab structure design was pull tested to the required force and met the appropriate criteria.
67 931
Bid #:
0735949
Certification, Cab HVAC System
Performance, SFR/Enf,
CD0165/CD0167/CD0174/CD0175
PERFORMANCE CERTIFICATIONS
Cab Air Conditioning
Good cab air conditioning temperature and air flow performance keeps occupants comfortable, reduces humidity, and provides a climate for recuperation while at the scene. The cab air conditioning system will cool the cab from a heat-soaked condition at 100
degrees Fahrenheit to
an average of
78 degrees Fahrenheit in
30 minutes. The bidder will certify that a substantially similar cab has been tested and has met these criteria.
Cab Defroster
Visibility during inclement weather is essential to safe apparatus performance. The defroster system will clear the required windshield zones in accordance with SAE J 381
Windshield
Defrosting Systems Test Procedure And Performance Requirements - Trucks, Buses, And Multipurpose Vehicles.
The bidder will certify that the defrost system design has been tested in a cold chamber and passes the SAE J
381
criteria.
Cab Auxiliary Heater
Good cab heat performance and regulation provides a more effective working environment for personnel, whether in-transit, or at a scene. An auxiliary cab heater will warm the cab 77 degrees
Fahrenheit from a cold-soak, within
30 minutes when tested using the coolant supply methods found in SAE J
381
. The bidder will certify, at time of delivery, that a substantially similar cab has been tested and has met these criteria.
0545073
Amp Draw Report, NFPA Current
Edition
AMP DRAW REPORT
The bidder will provide, at the time of bid and delivery, an itemized print out of the expected amp draw of the entire vehicle's electrical system.
The manufacturer of the apparatus will provide the following:
Documentation of the electrical system performance tests.
A written load analysis, which will include the following:
The nameplate rating of the alternator.
The alternator rating under the conditions specified per:
Applicable NFPA
1901
or
1906
(Current Edition).
The minimum continuous load of each component that is specified per:
Applicable NFPA
1901
or
1906
(Current Edition).
Additional loads that, when added to the minimum continuous load, determine the total connected load.
Each individual intermittent load.
All of the above listed items will be provided by the bidder per the applicable NFPA 1901
or
1906
(Current Edition).
0002758
Amp Draw, NFPA/ULC Radio
Allowance
0799248
Appleton/Florida BTO
0000018
PUMPER, 2ND GEN
0000012
PIERCE CHASSIS
0735525
PACCAR MX13 ENGINE
0046396
EVS 4000 Series TRANSMISSION
0020011
WATEROUS PUMP
0020009
POLY TANK
0028048
FOAM SYSTEM
0020006
SIDE CONTROL
0020007
AKRON VALVES
0020015
ABS SYSTEM
0658751
PUMPER BASE
68 931
Bid #:
69 931
Bid #:
Option
Description
Type*
Minimum
Load
Intermittent
Load
Total
Connected
0001244
High Idle w/Electronic Engine, Custom
0.00 1.20
0.00 0005945
Light, Pump Compt
0.00 1.80
0.00 0006825
Reel, Elect Cable, Hannay, 1600, (3) Wire
0.00 36.00
0.00 0007827
Foam Sys, FoamPro 2002 (Single Agent)
0.00 60.00
0.00 0010670
ABS Wabco Brake System, Single rear axle
0.00 6.00
0.00 0044860
Test Port, Electronic, Pump RPM, Waterous Pump
0.00 0.00
0.08 0062992
Gauge, Foam Level, (1) Tank, Class 1, GAAAR 5lt
0.00 0.00
1.00 0069390
Control, Air Horn At Pmp Pnl, Red Button
0.00 0.16
0.00 0072153
Primer, Trident, Air Prime, Air Operated
0.00 0.01
0.00 0079212
Batteries, (6) Stryten/Exide Grp 31, 950 CCA each, SAE Posts
0.00 3.00
0.00 0511256
Reel, Booster, Steel - Over Pump, Right Side, NPSH Fitting
0.00 36.00
0.00 0543751
Light, Do Not Move Apparatus
0.00 0.80
0.00 0549333
Indicators, Engine, Included with Pressure Controller
0.00 0.35
0.00 0554191
Handlight, Streamlight, Fire Vulcan, 44451, C4 LED, Tail Lights, 12v, Orange
0.00 1.00
0.00 0583938
Lights, Engine Compt, Custom, Auto Sw, Wln 3SC0CDCR, 3" LED, Trim
0.00 0.30
0.00 0589905
Alarm, Back-up Warning, PRECO 1040
0.00 0.50
0.00 0605741
Lightbars, Wln, Freedom IV, 2-21.5", RRRR RRRR
0.00 0.00
14.56 0614669
Light, Map, Overhead, Round, Add, Sunnex SL9-200B25L LED Clr Lens, Ceiling Mount
0.00 0.74
0.00 0622582
Cab Lift, Elec/Hyd, Manual Override, Control Loc Feature, Sab FR/Enf
0.00 180.00
0.00 0628471
Light, Map, Overhead, Peterson M371S LED, Rectangula
w/Switch
0.00 0.24
0.00 0630636
Controls, Electric Roll-Up Windows, 4dr, 4 Driver Controls, Saber FR/Enforcer
0.00 26.00
0.00 0645683
Lights, Rear Scene, Wln, M9LZC LED
0.00 0.00
12.00 0653526
Camera, Pierce, LS Mux, R, Camera
0.00 1.20
0.00 0663247
Intercom, Firecom 5100D Single Radio, 4-Pos, D,O,2C
0.00 0.00
0.50 0698585
Lights, Side Scene, Wln M9LZC Gradient LED, 2nd,
0.00 0.00
6.00 0698589
Lights, Side Scene, Wln M9LZC Gradient LED, 1st
0.00 0.00
6.00 0727913
Spotlight, Golight/RadioRay, Model 20**4GT, LED, 2 Lts
0.00 0.00
7.40 0735687
Engine Brake, Fully Integrated, Paccar MX13 Engine
0.00 0.42
0.00 0774308
Lights, Wln, P*H2* Pioneer, 12 VDC, 2nd
0.00 0.00
13.00 0774309
Lights, Wln, P*H2* Pioneer, 12 VDC, 1st
0.00 0.00
13.00 0776075
Light, Visor, Wln, 12V P*H1* Pioneer LED 1st
0.00 0.00
6.50 0803875
Radio, AM/FM/WB, Jensen, Frt,Rear Aux In/Frt,Rear
USB/Bluetooth
0.00 0.00
2.00 0804646
Light, Directional, Wln M62T* LED, Below Headlights, Sab/Enf
0.00 0.00
0.00 0806466
Lights, Backup, Wln M62BU, LED, For Tail Lt Housing
0.00 3.20
0.00 0809780
Compt, 15 W x 14.5 LS/24.5 RS H x 15 D, Ea Side CC, Dbl Pan, DEF, 70" Enf
0.00 0.00
0.00 0814764
Inverter/Bat Charger, Xantrex Freedom 817-2080, GFCI, Non- NFPA
0.00 0.00
99.66 0888084
Lights, Fog, PIAA RF6 (07206) LED, Rectangular, pair, Recessed into Bumper
0.00 0.00
2.50 0895310
Siren, Federal Q2B
0.00 100.00
0.00 0547505
Wiring, Spare, 10 A 12V DC 1st
Load Managed
0.00 0.00
20.00 0548004
Wiring, Spare, 15 A 12V DC 1st
Load Managed
0.00 0.00
30.00 0548006
Wiring, Spare, 15 A 12V DC 2nd
Load Managed
0.00 0.00
90.00 0548009
Wiring, Spare, 20 A 12V DC 1st
Load Managed
0.00 0.00
20.00 0722696
HVAC, Enforcer, CARE
Load Managed
0.00 0.00
100.00
0002758
Amp Draw, NFPA/ULC Radio Allowance
NFPA
5.00 0.00
0.00 0023650
LS 152" Rollup, Full Height Front & Rear, FDLER
NFPA
4.50 0.00
4.50 0063658
RS 152" Rollup, Full Height Front & Rear, FDLER
NFPA
4.50 0.00
4.50 0083700
Compt, Rear, Rollup, 37.75" FF, 25.88" D
NFPA
0.90 0.00
0.90 * UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 1 Electrical Analysis
8/4/2023
Bid #:
931
Visalia Fire, Enforcer Type 1 Pumper
Sales Rep:
Organization:
Young, Dewayne
Golden State Fire Apparatus, Inc
Desc:
Job #:
Customer:
VISALIA FIRE DEPARTMENT
Option:
Pierce Command Zone, Advanced Electronics & Control
System, Enforcer, WiFi CZT
Type:
Multiplexed
Option
Description
Type*
Minimum
Load
Intermittent
Load
Total
Connected
0092582
Load Manager/Sequencer, MUX
NFPA
0.56 0.56
0.00 0512558
Platform, Slide Out, 500 lb Capacity, Alum 4-Way, Full Width NFPA
3.00 0.00
0.00 0536401
Gauges, Engine, Included With Pierce Pressure Controller NFPA
0.30 0.00
0.00 0556360
Lights, Step, P25 LED 4lts, Pump Pnl Sw
NFPA
1.00 0.00
0.00 0564655
Lights, Rear Zn Lwr, Wln M6*C LED, Clear Lens, For Tail Lt Housing
NFPA
1.80 2.70
0.00 0587034
Air Dryer, Bendix, AD-IP w/Heat, 2010
NFPA
4.70 0.00
0.00 0593161
Light Shield, S/S LED
NFPA
3.00 0.00
0.00 0602730
Siren, Wln 295SLSA1, 100 or 200 Watt, Other Speaker, Non- NFPA 2016
NFPA
1.56 14.06
0.00 0603606
Cab Instruments, Ivory Gauges, Chrome Bezels, Enf MUX
NFPA
1.26 0.00
0.00 0615386
Vehicle Information Center, 7" Color Display, Touchscreen, MUX NFPA
1.20 0.00
0.00 0620054
Light, Directional/Marker, Intermediate, Weldon 9186-8580-29 LED 2lts
NFPA
0.10 0.90
0.00 0627282
Lights, Clearance/Marker/ID, Rear, FRP LED Bar & P25 LED 4Lts NFPA
1.75 0.00
0.00 0647638
Lights, Dome, Weldon Dual LED 4 Lts
NFPA
0.80 0.80
0.00 0647899
Lights, Directional/Marker, Cab Front Side, Weldon 9186-8580-29 LED, Sab/Enf
NFPA
0.80 0.00
0.00 0648332
Cab, Enforcer, 7010
NFPA
6.80 10.20
0.00 0653937
Flasher, Headlight Alternating
NFPA
0.08 0.00
0.00 0686562
Light, Rear Zone Up, Wln MCFLED2* LED
NFPA
3.00 0.00
0.00 0709438
Lights, Walk Surf, FRP Flood, LED
NFPA
2.00 0.00
0.00 0721609
Controller, Pressure, Pierce LCD, Custom Chassis
NFPA
1.70 0.00
0.00 0732620
Cabinet, Rear Facing, Top Eng Tnl, 43 W x 18 H x 16 D, Web, Notch, SFR/Enf
NFPA
0.20 0.20
0.00 0734655
DEF Tank, 7.3 Gallon, LS Fill, Under Cab, Paccar, Fill Dr, ENF NFPA
0.60 11.40
0.00 0735474
Lights, Clearance/Marker/ID, Front, P25 LED 7 Lts, Saber FR/Enforcer
NFPA
0.35 0.00
0.00 0737184
Indicator Light, Pump Panel, Ok To Pump, Green, LED
NFPA
0.10 0.00
0.00 0739224
Indicator Light @ Pump Panel, Throttle Ready, Incl w/Pressure Gov/Throttle,Green
NFPA
0.10 0.00
0.00 0747228
Lights, Side Zone Lower, Wln M6**, M6**, M6**, 6Lts
NFPA
5.40 8.10
0.00 0749925
Compt, Storage, (2) Rear Facing, Overhead, 21 W x 10 H x 12 D, Saber FR/Enforcer
NFPA
0.21 0.21
0.00 0750438
Water Level Gauge, Wln PSTANK2, LED 1-Light, 4-Level
NFPA
1.60 0.00
0.00 0750526
Gauge, Water Level, Pierce, In pressure Controller, Lt Driver NFPA
1.23 0.00
0.00 0769559
Lights, Perimeter Pump House, Amdor AY-LB-12HW012 LED 2lts NFPA
0.36 0.00
0.00 0769560
Lights, Perimeter Body, Amdor AY-LB-12HW012 LED 2lts, Rear Step
NFPA
0.36 0.00
0.00 0769569
Lights, Perimeter Cab, Amdor AY-LB-12HW012 LED 4Dr
NFPA
0.72 0.00
0.00 0780369
Lightbar, Wln, Freedom IV-Q, 72", RRRWR__Opt__RWRRR
NFPA
6.48 2.68
4.96 0783153
Headlights, Rect LED, JW Spkr Evo 2, AXT/DCF/Enf/Imp/Sab/Vel NFPA
4.20 4.20
0.00 0788759
Pump Shift, Air w/o Manual Override, Split Shaft, Interlocked, Wat, Left Switch
NFPA
1.00 0.00
0.00 0791463
Light, Traffic Directing, Wln TANF65, 34" Long LED
NFPA
2.00 4.00
0.00 0804514
Lights, Tail, Wln M62BTT* Red Stop/Tail & M62T* Amber Dir Arw For Hsg
NFPA
0.83 2.49
0.00 0808515
Engine, Paccar MX, 510HP, 1850 lb-ftW/OBD, EPA 2027,
Enforcer
NFPA
6.00 0.00
0.00 0887550
Trans, Allison 6th Gen, 4000 EVS P, Imp/Vel/Enf
NFPA
2.00 2.00
0.00 0889577
Bracket, License Plate & Light, P25 LED, Stainless Brkt NFPA
0.07 0.00
0.00 0892638
Lights, Cab & Crw Cab Acs Stps, P25, LED w/Bezel, 6lts
NFPA
1.00 0.00
0.00 0896904
Cabinet, Rear Facing, LS, 23.5 W x 30 H x 26.75 D, Roll, Ext Acc, SFR/Enf
NFPA
0.78 0.78
0.00 0896906
Cabinet, Rear Facing, RS, 23.5 W x 30 H x 26.75 D, Roll, Ext Acc, SFR/Enf
NFPA
0.30 0.30
0.00 0899300
Lights, Front Zone, Wln M6** M6RS M6RS M6**, Inside Steady Burn, 4lts Q Bez
NFPA
3.60 5.40
0.00 0647728
Alternator, 430 amp, Delco Remy 55SI
S
0.00 0.00
0.00 Load Totals:
89.80 529.90
459.06
* UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 2 Electrical Analysis
8/4/2023
Bid #:
931
Visalia Fire, Enforcer Type 1 Pumper
Sales Rep:
Organization:
Young, Dewayne
Golden State Fire Apparatus, Inc
Desc:
Job #:
Customer:
VISALIA FIRE DEPARTMENT
Option:
Pierce Command Zone, Advanced Electronics & Control
System, Enforcer, WiFi CZT
Type:
Multiplexed
Minimum Continuous Load
Supply:
268.00
Demand:
89.80 Variance:
178.20
Total Connected Load
Supply:
374.00
Demand:
288.86
Variance:
85.14 Note: Minimum Continous Load is in "Blocking Right of Way" mode.(Reference current edition of NFPA 1901) Note: Intermittent Load items are not factored in on any alternator load comparisons. These items are included on the report for reference only and should be looked at as amp draw exclusion items. (Reference current edition of NFPA 1901) Note: Total Connected Load "Demand" represents Total Connected Load minus any Load Managed items 268.00
374.00
Alternator Output at Idle:
Alternator Output at Governed Speed:
* UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 3 Electrical Analysis
8/4/2023
Bid #:
931
Visalia Fire, Enforcer Type 1 Pumper
Sales Rep:
Organization:
Young, Dewayne
Golden State Fire Apparatus, Inc
Desc:
Job #:
Customer:
VISALIA FIRE DEPARTMENT
Option:
Pierce Command Zone, Advanced Electronics & Control
System, Enforcer, WiFi CZT
Type:
Multiplexed
Turning Performance Analysis
Bid Number:
931
Chassis:
Enforcer Chassis
Department:
VISALIA FIRE DEPARTMENT
Body:
Pumper, Medium, Galvanneal, 2nd Gen
Parameters:
*Inside Cramp Angle:
45°
Axle Track:
82.92 in.
Wheel Offset:
4.68 in.
Tread Width:
16.3 in.
Chassis Overhang:
65.95 in.
Additional Bumper Depth:
7 in.
Front Overhang:
72.95 in.
Wheelbase:
195.5 in.
Calculated Turning Radii:
Inside Turn:
15 ft. 3 in.
Curb to curb:
29 ft. 5 in.
Wall to wall:
33 ft. 0 in.
Notes:
*Actual Inside cramp angle may be less than shown.
Curb to Curb turning radius calculated for 9.00 inch curb. 08/04/2023
Category
Option
Description
Bumpers
0606186
Bumper, Non-Extended, Saber FR/Enforcer
Tires, Front
0899288
Tires, Front, Goodyear, Armor MAX MSA, 425/65R22.50, 20 ply, Fire Service Speed
Axle, Front, Custom
0630705
Axle, Front, Oshkosh TAK-4, Non Drive, 19,500 lb, Enforcer Wheels, Front
0019611
Wheels, Front, Alcoa, 22.50" x 12.25", Aluminum, Hub Pilot
Definitions:
Inside CrampAngle
Maximum turning angle of the front inside fire.
Axle Track
King-pin to King-pin distance of front axle.
Wheel Offset
Offset from the center line of the wheel to the King-pin.
Tread Width
Width of the tire tread.
Chassis Overhang
Distance of the center line of the front axle to the front edge of the cab. This does not include the bumper depth.
Additional Bumper Wheel
Depth that the bumper assembly adds to the front overhang.
Wheelbase
Distance between the center lines of the vehicles front and rear axles.
Inside Turning Radius
Radius of the smallest circle around which the vehicle can turn.
Curb to Curb Turning Radius
Radius of the smallest circle around which the vehicle's tires can turn. This measures assumes a curb height of 9 inches.
Wall to Wall Turning Radius
Radius of the smallest circle around which the vehicle's tires can turn. This measures takes into account any front overhang due to chassis , bumper extensions and or aerial devices.
JROGHQVWDWHĆUHFRP
PRODUCT
WARRANTIES
Exhibit “C”
4 Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0008
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.
No specific exclusions apply
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:
Fire and Rescue Apparatus
Coverage:
One (1) Year Material and Workmanship
Basic Apparatus
Twelve (12) months.Warranty Period
Ends After:
The date the apparatus is placed in service, or 60 days from the original buyer invoice date, whichever comes first.Warranty Begins:
Portions of the apparatus manufactured by Pierce shall be free from defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
Fire and Rescue Apparatus
Coverage:
SUPPLIER
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:
Covers any failures of the engine which result, under normal use and service, from a defect in material or factory
workmanship.
1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the purchaser who first puts the product in service ("Buyer"):
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original buyer invoice.Warranty Begins:
This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.
See warranty for exclusions.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.
Five (5) years or 100,000 miles, whichever occurs firstWarranty Period Ends After:
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 3/19/2021 WA0386
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.
Oshkosh Corporation Classification - Restricted
PACCAR ENGINE LIMITED WARRANTY
PACCAR MX Warranty
United States
THIS LIMITED WARRANTY (“ LIMITED WARRANTY ”) LISTS THE RESPECTIVE RIGHTS AND RESPONSIBILITIES OF PIERCE MANUFACTURING INC.’S END USER CUSTOMER THAT FIRST PUTS THE PACCAR ENGINE INTO SERVICE (“ YOU” or “ FIRST PURCHASER”), PACCAR INC (“PACCAR”), AND THE SERVICING PACCAR ENGINE DISTRIBUTORS (“AUTHORIZED DISTRIBUTORS”). PLEASE READ THIS LIMITED WARRANTY CAREFULLY.
PACCAR warrants directly to You that the PACCAR MX engine and related kitted parts (collectively, the “Engine”) will be free from defects in materials and factory workmanship (“Warrantable Failures”) appearing under normal commercial use and service during the time, mileage or hour limitations set forth in the attached Warranty Schedule. This Engine warranty extends only to You, and not any subsequent owner or user of the Engine. The Emissions warranty is made to all owners of the Engine in the chain of distribution until the end of the Emissions warranty coverage period. Warranty coverage relating to the Emissions components is outlined in the Emissions Warranty section of the PACCAR MX Operator’s Manual, the terms and conditions of which are incorporated herein by reference.
YOUR SOLE AND EXCLUSIVE REMEDY AGAINST PACCAR AND ITS SUBSIDIARIES AND AFFILIATES ARISING FROM YOUR
PURCHASE AND USE OF THIS ENGINE IS LIMITED TO THE REPAI R OR REPLACEMENT OF WARRANTABLE FAILURES AT AUTHORIZED DISTRIBUTORS IN THE UNITED STATES AND CANADA AND IS SUBJECT TO PACCAR’S TIME, MILEAGE, AND HOUR LIMITATIONS LISTED IN THE ATTACHED WARRANTY SCHEDULES. The maximum time, mileage and hour limitations in the Warranty Schedules begin running on the Date of Delivery to the First Purchaser. The accrued time, mileage, or hours is calculated when this Engine is brought into an Authorized Distributor for correction of Warrantable Failures.
WARRANTY DISCLAIMER AND LIMITATIONS OF LIABILITY (ENGINE AND EMISSIONS) This Limited Warranty is the sole warranty made by PACCAR and its Authorized Distributors to You relating to the Engine. Except for the above limited express warranty, PACCAR and its Authorized Distribu tors make no other warranties to You, express or implied. PACCAR AND ITS AUTHORIZED DISTRIBUTORS EXPRESSLY DISCLAIM ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
IT IS AGREED THAT PACCAR AND ITS AUTHORIZED DISTRIBUTORS SHALL NOT BE LIABLE TO YOU FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING, BUT NOT LIMITED TO: LOSS OF INCOME OR LOST PROFITS; ENGINE OR VEHICLE DOWNTIME; THIRD PARTY DAMAGE, INCLUDING DAMAGE OR LOSS TO OTHER ENGINES, VEHICLES OR PROPERTY, ATTACHMENTS, TRAILERS AND CARGO; LOSS OR DAMAGE TO PERSONAL CONTENTS; COMMUNICATION EXPENSES; LODGING AND/OR MEAL EXPENSES; FINES; APPLICABLE TAXES OR BUSINESS COSTS OR LOSSES; ATTORNEYS’ FEES; AND ANY LIABILITY YOU MAY HAVE IN RESPECT TO ANY OTHER PERSON OR ENTITY.
This warranty does not apply to parts or accessories supplied by the vehicle manufacturer or third parties.
Failures of belts and hoses supplied by PACCAR are covered during the first year from the Date of Delivery of the Engine to the First Purchaser. PACCAR does not warrant antifreeze, lubricants, filters, filter elements, or any other part that is a maintenance or repair item. However, in its sole discretion, PACCAR may pay for lubricating oil, antifreeze, filter elements, belts, hoses, and other mainte nance or repair items if the need for replacing such items is due to a Warrantable Failure of the Engine.
You are responsible for the safe operation and maintenance of the Engine and Emissions equipment as specified in the applicable Operator’s Manuals. You are responsible for providing proof that all recommended ins pections and maintenance have been performed. Before the expiration of the applicable warranty, You must notify an Authorized Distributor of any Warrantable Failures and make the Engine available for Engine repair by such Authorized Distributor. You are responsible for delivery of the Engine to the Authorized Distributor. Locations in the United States and Canada of Authorized Distributors may be found at WWW.PACCARPOWERTRAIN.COM.
PACCAR IS NOT RESPONSIBLE FOR WEAR AND TEAR OR WEAROUT OF COVERED PARTS, storage deterioration, and changes in adjustment resulting from your use of the Engine. Damage due to accident, misuse, abuse, neglect, negligence, impr oper or insufficient maintenance, or unauthorized modification is not warranted. This may include, but is not limited to: operation without adequate coolants, lubricants, or other fluids; over-fueling; over-speeding; lack of maintenance of the lubricating, cooling or air intake systems; improper storage, starting, warm-up, run-in or shutdown practices; and unauthorized modifications to the Engine. PACCAR is not responsible for damage or loss resulting from Engine horsepower/torque upgrades.
Parts used to repair a Warrantable Failure may be new parts, approved remanufactured parts, or repaired parts. PACCAR is not responsible for failures resulting from the use of parts not approved by PACCAR. A new or approved remanufactured part used to repair a Warrantable Failure assumes the identity of the part it has replaced and is entitled to the remaining warranty coverage, if any.
PACCAR IS NOT RESPONSIBLE FOR DAMAGE OR LOSSES CAUSED BY INCORRECT OIL, FUEL, DIESEL EXHAUST FLUID, COOLANT, OR ADDITIVES; WATER, DIRT OR OTHER CONTAMINANTS IN THE FUEL, OIL OR DIESEL EXHAUST FLUID; OPERATION WITHOUT ADEQUATE COOLANTS OR LUBRICANTS; OVER -FUELING; OVER -SPEEDING; IMPROPER STORAGE, STARTING, WARM-UP, RUN-IN OR SHUT-DOWN PRACTICES; OR UNAUTHORIZED MODIFICATIONS OF THE ENGINE. Failure of replacement parts used in repairs due to the above non-warrantable conditions is not warrantable.
If your vehicle is disabled by a Warrantable Failure to the Engine during the base warranty period, PACCAR is not responsible fo r towing expenses to transport the vehicle to the nearest Authorized Distributor. In lieu of the towing expense and at the sole discretion of PACCAR,
Oshkosh Corporation Classification - Restricted
PACCAR will pay the reasonable costs of an authorized mechanic to travel to and from the location of the disabled Vehicle in order to perform the Engine repair.
PACCAR will pay for reasonable labor costs for Engine removal and reinstallation when necessary to repair a Warrantable Failure.
Warrantable Failures resulting in excessive oil consumption will be handled within the basic Engine coverage as stated in the attached Engine Schedule. Before a claim for excessive oil consumption, low power, or excessive fuel consumption will be considered for payment, You must submit adequate documentation to show that consumption exceeds PACCAR published standards
PACCAR reserves the right to inspect and download data from the Engine Electronic Control Module for purpose of failure analysis unless prohibited by applicable law.
TIME LIMIT ON COMMENCING LEGAL ACTION / OTHER TERMS
IT IS AGREED THAT YOU HAVE 12 MONTHS FROM THE ACCRUAL OF THE CAUSE OF ACTION TO COMMENCE ANY LEGAL ACTION ARISING FROM THE PURCHASE OR USE OF THE ENGINE, OR BE BARRED FOREVER.
To the extent any provision of this limited warranty is found to contravene the law of any jurisdiction, the remainder of the warranty shall not be affected thereby.
Oshkosh Corporation Classification - Restricted
PACCAR ENGINE LIMITED WARRANTY SCHEDULE
PACCAR MX Warranty
United States
THIS ENGINE WARRANTY SCHEDULE APPLIES ONLY TO ORIGINAL FACTORY EQUIPMENT AND IS SUBJECT TO THE TERMS AND LIMITATIONS IN THE ATTACHED LIMITED WARRANTY. This Engine Warranty Schedule does not apply to the vehicle which is warranted separately. Pursuant to the terms of the attached Limited Warranty, PACCAR Inc (“PACCAR”) will pay warranty claims for Warrantable Failures within the following maximum limits in time, mileage, or hours, whichever shall occur first. The Warrantable Failure must be brought to the attention of an Authorized Distributor within 30 days of discovery.
PACCAR MX Engine
Basic Engine -Twenty-four (24) months or 250,000 miles (or 400,000 km) or 6,250 hours - (all applications except fire apparatus)
Fire Apparatus Truck Applications Basic Engine - Sixty (60) months or 100,000 miles (or 160,000 km) or 6,250 hours
Major Engine Components - Sixty (60) months or 500,000 miles or 12,500 hours
Cylinder Block Casting Crankshaft Lube Pump Gear Flywheel Housing Main Bearing Bolts Camshaft Crankshaft Gear Water Pump Housing Cylinder Head Casting Cam Follower Assemblies Camshaft Gear Thermostat Housing Cylinder Head Capscrews Connecting Rod Assemblies Camshaft Idler Gear
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0013
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.
This warranty does not apply to damage caused by corrosion.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:
Fire and Rescue Apparatus
Coverage:
Lifetime Fifty (50) Year Structural Integrity
Custom Chassis Frame
Fifty (50) Years
(Expected Life of Apparatus)
Warranty Period
Ends After:
The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:
Custom chassis frame rail manufactured by Pierce shall be free from defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.
This limited warranty excludes brake pads, brake rotors, seal boots and shock absorbers.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGE S.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.
Three (3) Years
-or-
30,000 Miles
Warranty Period
Ends After:
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle.
12/16/2013 WA0050
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES
ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.
Fire and Rescue Apparatus
Coverage:
Three (3) Year Material and Workmanship
TAK-4 Independent Front Suspension
Limited Warranty Limited Warranty Limited Warranty Limited Warranty Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:
The TAK-4 Front Independent Suspension and Steering
Gears shall be free from defects in material and
workmanship.
1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:
Fire and Rescue Apparatus
Coverage:
SUPPLIER
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:
The Meritor axle shall be covered by Meritor as indicated in the attached Meritor warranty coverage description
1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the purchaser who first puts the product in service ("Buyer"):
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:
This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.
The exclusions listed in the attached Meritor warranty
description shall apply.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.
Five (5) YearsWarranty Period
Ends After:
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 6/29/2020 WA0384
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.
MERITOR
®
COMMERCIAL
VEHICLE SYSTEMS
WARRANTY/MODEL YEAR 2020 VEHICLES
Advantage Program
Purchasing additional coverage on select components will continue to safeguard your investment against major repair costs after the initial base coverage expires. You can find out more about the Advantage Program by visiting www.meritor.com or by contacting Meritor at 866-OnTrac1 (866-668-7221).
2 Linehaul ............................................................................................................. 3-4 General Service ................................................................................................... 5-6 Heavy Service/Specialty Vehicle .......................................................................... 7-8 Fire and Emergency ................................................................................................ 9 Transit Bus ........................................................................................................... 10 Off-Highway Service .............................................................................................. 11 Terms and Conditions ............................................................................................ 12 How to Read Warranty Coverage
Number of Years Mileage (in thousands)
Unl=Unlimited
P=Parts Only
P&L=Parts & Labor
Notice:
Models or components that are approved for use by Meritor’s vocational guidelines contained in Meritor Publication TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, which are not specifically listed, are warranted for one year, unlimited miles, parts only (1/Unl/P).
Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles parts only (1/Unl/P).
Effective Model Year 2020 Vehicles
WARRANTY INFORMATION CONTENTS
n Bulk Hauler
n Chip Hauler (Truck)*
n Doubles
n Flatbed
n General Freight
n Grain Hauler
n Livestock Hauler
n Moving Van
n Pipe Hauler
n Refrigerated Freight
n Tanker
n Triples
FD-965
FF-941
FF-942
FF-943
FF-944
FF-961
FF-966
FF-967
FG-941
FG-943
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122A-N
MFS-12-122B-N
MFS-12-122C-N
MFS-12E-122A-N
MFS-12E-122B-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12-132C-N
MFS-12E-132B-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12E-143A-N
MFS-12-144A-N
MFS-13-122A-N
MFS-13-122B-N
MFS-13-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-13B-122B-N
MFS-13B-122C-N
MFS-13B-132B-N
MFS-13B-132C-N
MFS-14-122A-N
MFS-14-124A-N
MFS-14-143A-N
MFS-14-144A-N
n High mileage operation (over 60,000 miles/year)
n Well maintained major highways of concrete or
asphalt construction
n Greater than 30 miles between starting and stopping
Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application approval questions on any product line. * Chip Hauler vehicles require specific axle models listed below and Linehaul condition to be eligible for Linehaul warranty consideration.
Linehaul Vehicles
Front Non-Drive Steer Axles – 5/750/P&L
Linehaul Typically Is
RPL 5/500/P , 1/Unl/P&L
MXL 3/350/P , 1/Unl/P&L
155N 1/Unl/P
92N 1/Unl/P
Drivelines
RS-19-144/145/A
MS-19-14X
MS-21-144
RS-21-145
RS-21-160
MS-23-17X
RS-23-160
RS-23-161
RS-23-186
Rear Drive Single Axles – 5/750/P&L
1 These models required for Chip Hauler and Linehaul warranty consideration. 2 Each vehicle must have a Request for Application Recommendation (RAR) approved by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details.
RT-34-144/P/A
RT-40-145/A
RT-40-160/P 1,2
RT-46-160/P 1,2
RT-46-164EH/P 1,2
RT-50-160/P 1,2
MA-40-165
MA-40-175
MT-34-14X/P
MT-40-14T/P
MT-40-14X/P
MT-40-14X/P
MT-40-14XHE
MT-40-144/P
MT-40-943
MT-40-943-SP
RZ-166 2
RZ-188
Rear Drive Tandem/Tridem Axles – 5/750/P&L
LINEHAUL WARRANTY INFORMATION
3 Cam Q Series Trailer Brakes 5/500/P , 1/100/L
Q+ Drum Brake™ 5/500/P , 1/Unl/P&L
ASA 5/500/P , 1/Unl/P&L
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
STEELite X30 Drum Brake™ 2 12-Years or Wearable Life/P
EX+ Air Disc Brake™ 5/500/P , 1/Unl/L
EX+ Air Disc Brake Extended Standard Warranty 3 5/500/P&L 1 Includes: bushing, seal, cam, ASA lubrication and wear coverage of 3/500/P&L.
2 Based on stamped wear diameter max.
3 Applies only to MA761 friction material code CD brake assembly i.e.
EX225LXXXCDXXX
MPA38/40 (Tandem Axle Parallelogram) 1
Major Structural Components 5/500/P , 1/100/L
Curbing Damage Warranty 2 5/500/P , 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs 2/200/P , 1/100/L
Bushings 5/P , 3/L
PinLoc Air Controls 1/100/P&L
PinLoc Actuator 3/300/P&L
MPA20 (Single Axle Parallelogram)
Major Structural Components 5/500/P , 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs 2/200/P , 1/100/L
Bushings 5/P , 3/L
MTA (Trailing Arm)
Major Structural Components 5/500/P , 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs & Rebound Straps 2/200/P , 1/100/L
Bushings 5/500/P , 3/300/L
1 Fastener torque coverage is limited to 2/Unl/P&L when torqued by Meritor (For axle and ABS coverage, refer to appropriate product warranties.) 2 “Curbing damage” is defined as deformation (bending, buckling, or breakage), caused by sudden impact with a curb or similar fixed object. Damage to the RideSentry slider box (the suspension sliding subframe, consisting of the frame rails, crossmembers, and central A-frame assembly), caused by accidental trailer impact with a curb or similar fixed object, is eligible for warranty coverage.
Damage to other components or damage resulting from collision with another vehicle, rollover or fire is not covered under this provision. Warranty is not transferrable to another trailer VIN, and coverage does not apply if the trailer is deemed to be a total loss, scrapped, or otherwise not salvageable.
TQ, TQD, TR, TRD Beam and Brackets 5/750/P&L
1 For brake components and ABS Coverage, refer to appropriate product warranties.
MTIS Components 5/Unl/P , 1/Unl/L
Beam and Brackets 5/500/P , 1/100/L
Wheel End Systems 1
Standard System 2 1/100/P&L
PreSet by Meritor 3 5/500/P&L
AxlePak5 4 5P/L
AxlePak7 5 7P/L
1 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage. 2 When installed by Meritor.
3 Requires approved hubcap stating PreSet by Meritor on hubcap face. 4 When specified with AxlePak5 wheel end system, coverage on MTIS thru-tee and stator is 5/Unl/P , 1/Unl/L.
5 When specified with AxlePak7 wheel end system, coverage on MTIS thru-tee and stator is 7/Unl/P , 1/Unl/L.
(For brake components and ABS coverage, refer to appropriate product warranties.)
Brake Components Trailer Air Suspension Systems
TAG/Pusher Axles1
Meritor Tire Inflation System
Trailer Axles
4 LINEHAUL WARRANTY INFORMATION
n Auto Hauler
n Beverage Truck
n Chip Hauler
n Cross Country Coach
n Flatbed
n Front Engine Commercial Chassis
n Front Engine Integral Coach
n General Freight
n Intercity Coach
n Intermodal Chassis
n Livestock Hauler
n Meat Packer
n Moving Van
n Municipal Truck
n Newspaper Delivery
n Pick-Up and Delivery
n Pipe Hauler
n Platform Auto Hauler
n Rear Engine Integral Coach
n Recreational Vehicles
n Refrigerated Freight
n School Bus
n Stake Truck
n Tanker
n Tanker Trailer
n Tour Bus
n Wrecker
FD-965
FF-941
FF-942
FF-943
FF-944
FF-946
FF-961
FF-966
FF-967
FG-941
FH-941
FH-946 1
FL-941
FL-943
MFS-6-151A-N
MFS-6-153B-N
MFS-6-162B-N
MFS-6-153C-N
MFS-6-162C-N
MFS-7-113C-N
MFS-7-153C-N
MFS-7-163C-N
MFS-8-113B-N
MFS-8-143A-N
MFS-8-153B-N
MFS-8-163B-N
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122A-N
MFS-12E-122A-N
MFS-12-122B-N
MFS-12E-122B-N
MFS-12-122C-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12E-132B-N
MFS-12-132C-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12-144A-N
MFS-12E-143A-N
MFS-13-122A-N
MFS-13-122B-N
MFS-13B-122B-N
MFS-13-122C-N
MFS-13B-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13B-132B-N
MFS-13B-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-14-122A-N
MFS-14-124A-N
MFS-14-143A-N
MFS-14-144A-N
MFS-16-122A-N
MFS-16-133A-N
MFS-16-135A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
n Lower mileage operations (less than 60,000 miles/year) n Generally, on-road service (less than 10% off-road)
n An average of three (3) miles between starting and stopping Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application approval questions on any product line.
General Service Vehicles
Front Non-Drive Steer Axles – 2/Unl/P&L
General Service Typically Is
GENERAL SERVICE WARRANTY INFORMATION
1 Can also be used with reduced steer angles in tag position in Coach Applications. 5 MS-17-13X
MS-17-14X
MS-19-13X
MS-19-14X
RS-17-144/145/A
RS-19-144/145/A
MS-21-13X
MS-21-14X
MS-21-144
MS-23-17X
RS-21-145/A
RS-21-160
RC-22-145
RC-22-145/A
RC-23-160
RC-23-161
RC-23-162 1
RC-23-165 1
RS-23-160
RS-23-161
RS-23-186
RS-24-160
RC-25-160
RS-26-185
MS-26-616
MS-26-616-SP
RS-30-185
MS-30-616
MS-30-616-SP
RS-35-380
71162
71163
79163
Rear Drive Single Axles – 2/Unl/P&L
1 3/Unl/P&L if PreSet by Meritor.
MT-34-14X/P
RT-34-144/P/A
MT-40-14T/P
MT-40-14X/P
MT-40-14XHE
MT-40-144/P
RT-40-145/A
MT-44-14X/P
RT-44-145/P
RT-46-169
MT-52-616
RT-52-1851
MT-58-616
RT-58-1851
MT-70-380
RZ-188
Rear Drive Tandem/Tridem Axles – 2/Unl/P&L
1 Each vehicle must have a Request for Application Recommendation (RAR) approved by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN.
Refer to Product Information Letter #303 and #396 for further details.
MX-08-130-FV (FSD-08A)
MX-10-130-FV (FSD-10A)
MX-12-130-FV (FSD-12A)
MX-13-130-FV (FSD-13A)
MX-14-130-FV (FSD-14A)
MX-16-130-FV (FSD-16A)
MX-18-130-FV (FSD-18A)
MX-18-130-SD (SDA-1800)
MX-20-130-FV (FSD-20A)
MX-21-130-FV (FSD-21A)
MX-21-130-SD (SDA-2100)
MX-23-130-FV (FSD-23A)
MX-23-130-SD (SDA-2300)
MX-29-130-FV (FSD-29A)
Front Drive/Non-Drive Steer Axles – 1/Unl/P&L
RT-40-160/P
RT-46-160/P
RT-46-164EH/P
RT-50-160/P
RZ-166
Rear Drive Tandem/Tridem -
3/Unl/P&L
RPL 4/400/P , 1/Unl/P&L
MXL 3/350/P , 1/Unl/P&L
155N 1/Unl/P
92N 1/Unl/P
Drivelines
11170
523
RND-14H
RND-16A
Rear Drive Axles – 1/Unl/P&L
MPT-318
MPT-500
MPT-510
MPT-518
MPT-526
MPT-531
MPT-543
MPT-170
MPT-1702
MPT-175
MPT-185
MPT-190
PTO – 1/Unl/P&L
516 FAT 30
Transmission – 1/Unl/P&L
Cam Q Series Trailer Brakes 3/Unl/P , 1/Unl/L
Cam P3 2/200/P
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
Q+ Drum Brake ™ 3 2/200/P&L
ASA 3/Unl/P
ASA3 2/200/P
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
STEELite X30 Drum Brake™ 2 12-Years or Wearable Life/P
EX+ Air Disc Brake™ 2/Unl/P&L
1 Includes: bushing, seal, cam, ASA lubrication and wear coverage of 1/Unl/P . 2 Based on stamped wear diameter max.
3 Applies to Tour Bus and Cross Country Coach only.
Beam and Brackets 1 5/Unl/P , 1/Unl/L
Wheel End Systems 2
Standard System 3 1/Unl/P&L
AxlePak5 4 5/P&L
AxlePak7 5 7/P&L
1 9000 Series is 3/Unl/P , 1/Unl/L
2 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage. 3 When installed by Meritor.
4 When specified with AxlePak5 wheel end system, coverage on MTIS thru-tee and stator is 5/Unl/P , 1/Unl/L.
5 When specified with AxlePak7 wheel end system, coverage on MTIS thru-tee and stator is 7/Unl/P , 1/Unl/L.
(For brake components and ABS coverage, refer to appropriate product warranties.)
Beam & Brackets 6/Unl/P , 1/Unl/L
Wheel End Systems 1
Standard System 1/Unl/P&L
AxlePak7 7/P&L
Beam and Brackets 7/P , 1/L
1 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage.
MPA38/40 (Tandem Axle Parallelogram) 1
Major Structural Components 5/Unl/P , 1/Unl/L
Curbing Damage Warranty 2 5/500/P , 1/100/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P , 1/Unl/L
Bushings 5/P , 3/L
PinLoc Air Controls 1/Unl/P&L
PinLoc Air Actuator 3/Unl/P&L
MPA20 (Single Axle Parallelogram)
Major Structural Components 5/Unl/P , 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P , 1/Unl/L
Bushings 5/P , 3/L
MTA (Trailing Arm)
Major Structural Components 5/Unl/P , 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs and Rebound Straps 2/Unl/P , 1/Unl/L
Bushings 3 5/Unl/P , 3/Unl/L
(For axle and ABS coverage, refer to appropriate product warranties.) 1 Fastener torque coverage is limited to 2/Unl/P&L when torqued by Meritor 2 “Curbing damage” is defined as deformation (bending, buckling, or breakage), caused by sudden impact with a curb or similar fixed object. Damage to the RideSentry slider box (the suspension sliding subframe, consisting of the frame rails, crossmembers, and central A-frame assembly), caused by accidental trailer impact with a curb or similar fixed object, is eligible for warranty coverage.
Damage to other components or damage resulting from collision with another vehicle, rollover or fire is not covered under this provision. Warranty is not transferrable to another trailer VIN, and coverage does not apply if the trailer is deemed to be a total loss, scrapped, or otherwise not salvageable. 3 Raw wood applications 3/Unl/P , 1/Unl/L
MTIS Components 5/Unl/P , 1/Unl/L
TQ, TQD, TR, TRD Beam and Brackets 1 3/Unl/P , 1/Unl/L MC14002, MC16003, FH946 2/Unl/P&L
(For brake components and ABS coverage, refer to appropriate product warranties.)
1 3/Unl/P&L if sold with PreSet by Meritor.
Brake Components
Trailer Axles
Chassis Axles (2000 Series/ChassiPak)
Trailer Air Suspension Systems
Meritor® Tire Inflation System
TAG/Pusher Axles
6 GENERAL SERVICE WARRANTY INFORMATION
Heavy Service/Specialty Vehicle
n Airport Rescue Fire Fighting
(ARFF)
n Airport Shuttle*
n Asphalt Truck
n Block Truck
n Bottom Dump Trailer
Combination
n Cementing Vehicle
n Commercial Pick-Up
n Concrete Pumper
n Construction Material Hauler
n Mixer
n Demolition
n Drill Rig
n Dump
n Equipment Hauling
n Flatbed Trailer Hauler
n Flatbed Truck
n Fracturing Truck
n Front Loader
n Geophysical Exploration
n Hopper Trailer Combinations
n Landscaping Truck
n Liquid Waste Hauler
n Log Hauling
n Lowboy
n Michigan Special Gravel Trains
n Michigan Special Log Hauler
n Michigan Special Steel Hauler
n Michigan Special Waste Vehicle
n Municipal Dump
n Rear Loader (Refuse)
n Recycling Truck
n Residential Pick-Up (Refuse)
n Rigging Truck
n Roll-Off
n Scrap Truck
n Semi-End Dump
n Sewer/Septic Vacuum
n Shuttle Bus*
n Side Loader
n Snowplow/Snowblower
n Steel Hauling
n Tanker
n Tank Truck
n Tractors with Pole Trailers
n Tractor/Trailer with Jeeps
n Transfer Dump
n Transfer Vehicle
n Utility Truck
n Winch Truck
n Moderate mileage operation (less than 60,000 miles per year) n On/Off road vocations (10% or more off-road)
n Moderate to frequent stops/starts (up to 10 stops per mile) Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/ or contact Meritor regarding specific application approval questions on any product line.
Heavy Service/Specialty Vehicle Typically Is
FD-965
FF-941
FF-942
FF-943
FF-944
FF-946
FF-961
FF-966
FF-967
FG-941
FG-943
FH-941
FH-946
FL-941
FL-943
MFS-6-151A-N
MFS-6-153B
MFS-6-162B
MFS-6-162C
MFS-7-113C-N
MFS-7-153C-N
MFS-7-163C-N
MFS-8-113B-N
MFS-8-153B-N
MFS-8-163B-N
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122
MFS-12E-122
MFS-12-122B-N
MFS-12E-122B-N
MFS-12-122C-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12E-132B-N
MFS-12-132C-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12-144A-N
MFS-12-155
MFS-13-122
MFS-13-122B-N
MFS-13B-122B-N
MFS-13-122C-N
MFS-13B-122C-N
MFS-13-132B-N
MFS-13B-132B-N
MFS-13-132C-N
MFS-13B-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-13-155
MFS-14-122
MFS-14-124A-N
MFS-14-143A-N
MFS-14-144A-N
MFS-16-122A-N
MFS-16-133A-N
MFS-16-135A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-192A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
RF-16-145
RF-21-160
MX-10-120
MX-10-120 EVO
MX-12-120
MX-12-120 EVO
MX-14-120
MX-16-120
MX-18-120
MX-17-140
MX-19-140
MX-21-140
MX-21-160
MX-23-160
MX-810
Front Drive/Non-Drive Steer Axles – 2/Unl/P&L
HEAVY SERVICE/SPECIAL TY VEHICLE
WARRANTY INFORMATION
7 *Commercial chassis only
MS-17-14X
RS-17-144/145/A
MS-19-14X
RS-19-144
MS-21-114
MS-21-14X
RS-21-145
RS-21-145/A
RS-21-160
RC-22-145
RC-23-160
RH-23-160
RS-23-160
RC-23-161
RS-23-161
RS-23-186/380
RS-24-160
RS-25-160
MS-26-616
MS-26-616-SP
RS-26-185/380
MS-30-616
MS-30-616-SP
RS-30-185/380
MS-35-380
RS-38-380
RC-25-160
RC-26-633
MT-58-616
MT-58-616-SP
Rear Drive Single Axles – 2/Unl/P&L
RPL 3/Unl/P , 1/Unl/P&L
92N 1/Unl/P&L
MXL 1/Unl/P&L
Drivelines
11170
523
RND-14H
RND-16A
Rear Drive Axles – 1/Unl/P&L
MX-08-130-FV (FSD-08A)
MX-10-130-FV (FSD-10A)
MX-12-130-FV (FSD-12A)
MX-13-130-FV (FSD-13A)
MX-14-130-FV (FSD-14A)
MX-16-130-FV (FSD-16A)
MX-18-130-FV (FSD-18A)
MX-18-130-SD (SDA-1800)
MX-20-130-FV (FSD-20A)
MX-21-130-FV (FSD-21A)
MX-21-130-SD (SDA-2100)
MX-23-130-FV (FSD-23A)
MX-23-130-SD (SDA-2300)
MX-29-130-FV (FSD-29A)
Front Drive/Non-Drive Steer Axles – 1/Unl/P&L
MPT-318
MPT-500
MPT-510
MPT-518
MPT-526
MPT-531
MPT-543
MPT-170
MPT-1702
MPT-175
MPT-185
MPT-190
PTO – 1/Unl/P&L
516
FAT 30
Transmission – 1/Unl/P&L
MT-34-14X/P
RT-34-144/P/A
MT-40-14X/P
RT-40-145/A
MT-44-14X/P
RT-44-145/P
RT-46-169
RT-58-160
MT-52-616
MT-52-616-SP
RT-52-185/380 1,2
MT-58-616
MT-58-616-SP
RT-58-185/380 1,2
RT-70-380
MT-70-380
RZ-188
Cam P 3/Unl/P
Cam P3 2/100/P
Cam Cast Plus™ 2/100/P&L
Q+ Drum Brake™ 3/Unl/P&L
Q+ Drum Brake™ 2 2/100/P&L
ASA 3/Unl/P
ASA2 2/100/P
Hubs/Cast Drums and
Other Wheel-end
Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake 2/100/P&L
1 Based on stamped wear diameter max.
2 Applies to City Bus, Trolley, Shuttle Bus and Airport Shuttle only.
3 Warranty for all non-Meritor ASAs supplied by
Meritor for all Heavy Service vocations is 1/100/P .
RT-40-160/P/A 3
RT-46-160/P/A 1,3
RT-46-164EH/P/A 2,3
RT-50-160/P/A 3
RZ-166
1 U.S. only. Canadian warranty = 1/Unl/P for
combination vehicles only.
2 Axle model designated will vary according to options and variations specified on these axles. Contact
Meritor Axle Applications Engineering for details.
3 Each vehicle must have a Request for Application
Recommendation (RAR) approved by Meritor prior
to vehicle build. All RARs must identify the chassis
number or VIN. Refer to Product Information Letter
#303 and #396 for further details.
1 Axle model designated will vary according to options and variations specified on these axles. Contact Meritor Axle Applications Engineering for details. 2 Each vehicle must have a Request for Application Recommendation (RAR) approved by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN.
Refer to Product Information Letter #303 and #396 for further details.
Rear Drive Tandem/Tridem Axles – 2/Unl/P&L
Brake Components Rear Drive Tandem/Tridem -
3/Unl/P&L MTA (Trailing Arm)
Major Structural Components1 5/Unl/P , 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P , 1/Unl/L
Bushings 1 5/Unl/P , 3/Unl/L
1 Raw wood applications 3/Unl/P , 1/Unl/L
(For axle and ABS coverage, refer to appropriate
product warranties.)
Trailer Air Suspension Systems
MTIS Components 5/Unl/P , 1/Unl/L
Meritor Tire Inflation System
Beam and Brackets 1 5/Unl/P , 1/Unl/L
Wheel End Systems 2
Standard System 3 1/Unl/P&L
1 9000 Series is 3/Unl/P , 1/Unl/L.
2 Includes hub, wheel seals and wheel bearings—all
systems require annual inspections and proper
documentation to ensure full coverage.
3 When installed by Meritor.
(For brake components and ABS coverage,
refer to appropriate product warranties.)
Trailer Axles
8 HEAVY SERVICE/SPECIAL TY VEHICLE
WARRANTY INFORMATION
MTC-4213
MTC-4210
MTC-4208
MTC-4206-FV (TC-38)
MTC-3106-FV (TC-137)
MTC-3111 (T-2111)
MTC-3112-CV (529 & 548C)
MTC-3116 (T-2111)
MTC-3118-FV (TC-180 & TC-180-23)
MTC-3118-CV (358)
MTC-3120-FV (TC-143)
MTC-3124 (T-2119)
MTC-3205-GV (MTC-25/247)
MTC-3205-GV (MTC-25/350)
MTC-3205-GV (RTC-25/350)
MTC-3206-FV (TC-237)
MTC-3206-CS (544)
MTC-3208-GV (RTC-50)
MTC-3209-GV (RTC-60/420)
MTC-3209-GV (RTC-60/380)
MTC-3209-GV (MTC-60/420)
MTC-3209-GV (MTC-60/380)
MTC-3212-CV (315 & 548B)
MTC-3312-FV (TC-270)
MTC-3220-FC (TC-142)
MTC-2212-CV (306)
Transfer Cases – 1/Unl/P
MGX-240
MGX-279
MGX-279D
MGX-280
MGX-285
MGX-292
MGX-314
MGX-376
MGX-377
MGX-378
MGX-380
MGX-384
MGX-402
MGX-413
MGX-448
MGX-456
MGX-478
MGX-480
MGX-487
MGX-488
MGX-505
MGX-506
MGX-514
MGX-519
MGX-520
MGX-522
MGX-524
MGX-527
MGX-528
MGX-533
MGX-534
MGX-536
MGX-537
MGX-541
MGX-545
MGX-546
MGX-550
Gearboxes – 1/Unl/P&L
n Aerial Ladder Truck
n Aerial Platform
n Ambulance
n Command Vehicle
n Crash Fire Rescue (CFR)
n Pumper
n Rapid Intervention Vehicle (RIV)
n Tanker
FL-941
FL-943
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
MX-19140
MX-21140
MX-21160
MX-23160
MX-23810
n Lower mileage operations (less than 20,000 miles/year) n Generally, on-road service (less than 10% off-road)
n An average of three (3) miles between starting and stopping Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application approval questions on any product line.
Fire and Emergency Vehicles
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
ASA 3/Unl/P
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake™ 2/Unl/P&L
1 Includes: bushing, seal, cam, ASA lubrication and wear coverage of 1/Unl/P .
Brake ComponentsFront Non-Drive Steer Axles – 5/Unl/P&L Front Drive Steer Axles – 2/Unl/P&L
Fire and Emergency Typically Is
RPL 4/400/P , 1/Unl/L
MXL 3/350/P , 1/Unl/L
155N 1/Unl/P
92N 1/Unl/P
Drivelines
MTC-4208
MTC-4210
MTC-4213
MTC-3111 (T-2111)
MTC-3116 (T-2111)
MTC-3124 (T-2119)
Transfer Cases – 1/Unl/P
RC-23-160
RS-23-160
RS-23-161
RS-23-186
RS-24-160
RC-25-160
RS-26-185
RS-30-185
RS-35-380
RS-25-160
Rear Drive Single Axles – 5/Unl/P&L
1 3/Unl/P&L if PreSet by Meritor.
MT-40-14X/P
MT-40-144/P
RT-40-145/A
RT-40-160/P
MT-44-14X/P
RT-44-145/P
RT-46-160/P
RT-46-164EH/P
RT-46-169
RT-50-160/P
MT-52-616
RT-52-1851
MT-58-616
RT-58-1851
MT-70-380
Rear Drive Tandem/Tridem Axles – 5/Unl/P&L
1 Each vehicle must have a Request for Application Recommendation (RAR) approved by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details.
FIRE AND EMERGENCY WARRANTY INFORMATION
9 Transit Bus Vehicles
Cam Cast Plus™ 2/100/P&L
Q+ Drum Brake™ 1 2/100/P&L
ASA1 2/100/P
Hubs/Cast Drums and
Other Wheel-end
Components 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake 2/100/P&L
1 Applies to City Bus, Trolley, Shuttle Bus and Airport Shuttle only.
MC-26000
71063
79063
Brake Components Center Non-drive Axles – 5/300/P&L
n Airport Shuttle
n City Bus
n Commuter Coach
n Shuttle Bus
n Transit Bus
n Trolley
n Moderate mileage operation (less than 50,000 miles per year) n Moderate to frequent stops/starts (up to 10 stops per mile) Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP- 9441 for axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application approval questions on any product line.
Transit Bus Typically Is
FH-946
FH-941 1
MFS-12-155
MFS-13-155
RS-23-160
RC-23-161
71163
79163
RC-23-162 1
RC-23-165 1
RS-21-160
Front Drive/Non-Drive Steer Axles – 5/300/P&L
Rear Drive Single Axles – 5/300/P&L
RPL 3/Unl/P , 1/Unl/L
92N 1/Unl/P&L
MXL 1/Unl/P&L
MC-14002
MC-16003
FH-946
Drivelines
Tag Axles – 2/Unl/P&L
TRANSIT BUS WARRANTY INFORMATION
10 1 Commuter coach only – 2/Unl/P&L
1 Commuter coach only – 2/Unl/P&L
Industrial And Off-Highway Service Vehicles
n Load-On/Load-Off
n Port Tractor
n Rail Yard Spotter
n Roll-On/Roll-Off
n Stevedoring Tractor
n Trailer Spotter
n Yard Jockey
n All-Terrain Crane
n Rough Terrain Crane
n Forestry
n Material Handling
n Specialized Heavy Haul
n Specialized Mining
n Excavator
n Compactor
n Fertilizer Spreader
n Snow Blower
n Mining
n Rail Car Mover
n Loader
n Tow Tractor
n Pushback Tractor
n Low mileage operation
n Low speed vehicle speed restriction
n Vehicles are not typically licensed for highway use
n Six (6) starts/stops per mile (typical)
Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Contact Meritor regarding specific application approval questions on any product line.
RPL MXL
FF - 941
FF - 943
FF - 961
FF - 966
FG - 941
FG - 943
FL - 941
FL - 943
FN - 951
MFS-12-143A-N
MFS-12-144A-N
MFS-13-143A-N
MFS-13-144A-N
MFS-14-143A-N
MFS-16-122A-N
MFS-16-133A-N
MFS-16-135A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
MON-Z0 FAMILY
Industrial And Off-Highway Service Typically Is
Drivelines – 1/Unl/P
MOB
MOC
MOD
MOE
MOF
MOG
MOH
MOR
MOS
MOT
MOX
MOY
MOZ
Planetary Axles – 1/Unl/P
Cam P 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
ASA 3/Unl/P
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
Brake ComponentsFront Non-Drive Steer Axles – 1/Unl/P
OFF-HIGHWAY SERVICE WARRANTY
INFORMATION
11 MTC-4213
MTC-4210
MTC-4208
MTC-4206-FV (TC-38)
MTC-3106-FV (TC-137)
MTC-3111 (T-2111)
MTC-3112-CV (529 & 548C)
MTC-3116 (T-2111)
MTC-3118-FV (TC-180 & TC-180-23)
MTC-3118-CV (358)
MTC-3120-FV (TC-143)
MTC-3124 (T-2119)
MTC-3205-GV (MTC-25/247)
MTC-3205-GV (MTC-25/350)
MTC-3205-GV (RTC-25/350)
MTC-3206-FV (TC-237)
MTC-3206-CS (544)
MTC-3208-GV (RTC-50)
MTC-3209-GV (RTC-60/420)
MTC-3209-GV (RTC-60/380)
MTC-3209-GV (MTC-60/420)
MTC-3209-GV (MTC-60/380)
MTC-3212-CV (315 & 548B)
MTC-3312-FV (TC-270)
MTC-3220-FC (TC-142)
MTC-2212-CV (306)
Transfer Cases – 1/Unl/P
MGX-240
MGX-279
MGX-279D
MGX-280
MGX-285
MGX-292
MGX-314
MGX-376
MGX-377
MGX-378
MGX-380
MGX-384
MGX-402
MGX-413
MGX-448
MGX-456
MGX-478
MGX-480
MGX-487
MGX-488
MGX-505
MGX-506
MGX-514
MGX-519
MGX-520
MGX-522
MGX-524
MGX-527
MGX-528
MGX-533
MGX-534
MGX-536
MGX-537
MGX-541
MGX-545
MGX-546
MGX-550
Gearboxes – 1/Unl/P&L
Coverage Exclusions
Product Description
All
The cost of any repairs, replacements or adjustments to a covered component (1) associated with noise; (2) resulting from the use or installation of non-genuine Meritor components or materials; (3) due to vibration associated with improper operation or misapplication of drivetrain components; and (4) damage resulting from corrosion.
For axle assemblies supplied by Meritor with suspension and in - terface brackets designed and/or attached by non-Meritor parties, Meritor warranty coverage does not apply to the brackets, bracket attachment methods, and field issues caused by brackets or bracket attachments to any covered component unless specified in a separate OEM agreement.
Front Axles
King Pin Bushings.
Rear Axles
Self-contained traction equalizers and oil filters. The use of NoSPIN differentials will result in the exclusion of axle shafts from warranty considerations. NoSPIN is a product of Eaton.
ASA
Boot and bushing. Bent, broken, over-torqued, missing or otherwise damaged pawl assemblies.
Cam Brake
Brake lining wear and brake shoe “rust-jacking.”
Disc Brake
Pad wear, rotor wear.
Coverage Limitations
Product Description
All
Any claim beyond 60 days from date of repair will not be accepted or honored under this warranty program. Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles parts only (1/Unl/P).
Front Axles
Tie rod and tie rod ends limited to 3-year/300,000-mile or published vocational coverage, whichever is less. Wheel seals, gaskets and wheel bearings are covered for 1 year/unlimited miles if the wheel end equipment is supplied and assembled by Meritor.
Rear Axles
Pinion and through shaft seals limited to 3-year/300,000-mile or published vocational coverage, whichever is less, if yoke is installed by Meritor. If yoke is not installed by Meritor, then Meritor does not warrant pinion seals. Wheel seals, gaskets and wheel bearings are covered for 1 year/unlimited miles if the wheel end equipment is supplied and assembled by Meritor.
Rear Axles
The Meritor ® breather part number A-2297-C-8765 with
A-3196-J-1336 hose must be used for eligibility of any potential warranty consideration relating to contamination and/or loss of lube in axles.
Cam Brake
Limited to bracket, brake spider and camshaft structural integrity.
STEELite X30
Wearable life is up to the discard diameter of the drum.
Disc Brake
Warranty coverage for boots, seals, bushings and pins is 2/200/P .
Warranty coverage for pads is 1/100/P .
Warranty coverage on vehicles with 1,850 lb-ft engine torque and over may be reduced on individual drivetrain components. Contact your Meritor representative for specific details.
12 TERMS AND CONDITIONS
For more information:
call Ontrac at 866-668-7221
or visit meritor.com
©2018 Meritor, Inc.
Litho in USA, SP-95155
Revised 1-19 (47865/11900)
Meritor Heavy Vehicle Systems, LLC
2135 West Maple Road
Troy, Michigan 48084 USA
Product models, brands, names and trademarks depicted herein are the property of their respective owners and, except where otherwise indicated, are not in any way associated with Meritor Heavy Vehicle Systems, LLC, or any parent or affiliate, thereof.
TERMS AND CONDITIONS
(1) What is Covered by this Commercial Warranty?
Meritor Heavy Vehicle Systems, LLC warrants to the owner (“Owner”) that the components listed in this publication, which have been installed by an Original Equipment Manufacturer (“OEM”) as original equipment in vehicles licensed for on-highway use, will be free from defects in material and workmanship. This warranty coverage begins only after the expiration of the OEM’s vehicle warranty for the applicable covered components. Warranty coverage ends at the expiration of the applicable time period from the date of vehicle purchase by the first Owner, or, the applicable mileage limitation, whichever occurs first.
Duration of coverage varies by component and vocation as detailed elsewhere in this warranty statement.
Some components are warranted for parts only and the Owner must pay any labor costs associated with the repair or replacement of the component. Other components are warranted for both parts and reasonable labor to repair or replace the subject component.
Components (whether new, used or remanufactured) installed as replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty.
For certain components, coverage requires the use of specific extended drain interval or synthetic lubricants. For further information about lubrication and maintenance, see Meritor publication Maintenance Manual Number l and the applicable Meritor
maintenance manual for the product in question. Other conditions and limitations applicable to this warranty are detailed below. (2) Designation of Vocational Use Required.
To obtain warranty coverage, each Owner must notify Meritor through the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the Meritor components have been incorporated prior to the vehicle in-service date. This notification may be accomplished by registering the vehicle through your OEM new truck and/or trailer dealer or with Meritor directly. Failure to notify Meritor of (I) the intended vocational use of the vehicle or (II) a change in vocational use from that which was originally designated, will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial in-service date.
A second Owner and each subsequent Owner must also notify Meritor as to the intended vocational use of the vehicle. This notification can be sent directly to Meritor or through the OEM new truck and/or trailer dealer. The duration and mileage coverage of this warranty cannot exceed the coverage extended to the first Owner after his or her initial designation of vocational use.
Coverage under Meritor’s warranty requires that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application approval questions on any product line.
(3) What is the Cost of this Warranty?
There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty?
This warranty does not cover normal wear and tear; nor does it cover a component that fails, malfunctions or is damaged as a result of (I) improper installation, adjustment, repair or modification (including the use of unauthorized attachments or changes or modification in the vehicle’s configuration, usage, or vocation from that which was originally approved by Meritor), (II) accident, natural disaster, abuse, or improper use (including loading beyond the specified maximum vehicle weight or altering engine power settings to exceed the axle and/or driveline capacity), or (III) improper or insufficient maintenance (including deviation from approved lubricants, change intervals, or lube levels). This warranty does not cover any component or part that is not branded by Meritor. For vehicles that operate full or part time outside of the United States and Canada, a one year, unlimited mileage, parts only warranty (1/Unl/P) will apply. (5) Remedy.
The exclusive remedy under this warranty shall be the repair or replacement of the defective component at Meritor’s option. Meritor reserves the right to require that all applicable failed materials are available and/or returned to Meritor for review and evaluation. (6) Disclaimer of Warranty.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES
OR CONDITIONS, EXPRESSED, IMPLIED OR STATUTORY INCLUDING
ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
PARTICULAR PURPOSE.
(7) Limitation of Remedies.
In no event shall Meritor be liable for special, incidental, indirect, or consequential damages of any kind or under any legal theory, including, but not limited to, towing, downtime, lost productivity, cargo damage, taxes, or any other losses or costs resulting from a defective covered component.
(8) To Obtain Service.
If the Owner discovers within the applicable coverage period a defect in material or workmanship, the Owner must promptly give notice to either Meritor or the dealer from which the vehicle was purchased. To obtain service, the vehicle must be taken to any participating OEM new truck and/or trailer dealer or authorized Meritor service location.
The dealer will inspect the vehicle and contact Meritor for an evalu - ation of the claim. When authorized by Meritor, the dealer will repair or replace during the term of this warranty any defective Meritor component covered by this warranty.
(9) Entire Agreement.
This is the entire agreement between Meritor and the Owner about warranty and no Meritor employee or dealer is authorized to make any additional warranty on behalf of Meritor. This agreement allocates the responsibilities for component failure between Meritor and the Owner. )LUHDQG5HVFXH$SSDUDWXV
Coverage:
7KUHH
<HDU0DWHULDODQG:RUNPDQVKLS
0HULWRU:DEFR$%6%UDNH6\VWHP
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:
The Meritor Wabco ABS brake system shall be covered by
Meritor Wabco as indicated in the attached Meritor Wabco warranty coverage description
/,0,7(':$55$17<
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.
Three (3) YearWarranty Period
Ends After:
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.
The exclusions listed in the attached Meritor Wabco warranty description shall apply.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
(;&/86,212)&216(48(17,$/$1',1&,'(17$/'$0$*(6
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
%8<(5
6(;&/86,9(5(0('<
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle.
2/25/2013 WA0232
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES
ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
',6&/$,0(562):$55$17,(6
capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.
WARRANTY
Warranty coverage is essential to protecting your investment. But understanding the full details of your coverage can be challenging. This straightforward approach allows you, our valued customer, to better understand how your specific vehicle applications will be covered in your region. Our component warranty coverage is provided according to vocation/usage categories listed below. • Linehaul covers high mileage operation (over 60,000 miles/year) on well-maintained major highways of concrete or asphalt construction.
• General Service covers moderate mileage operations (less than 60,000 miles/year) on well-maintained public roads (less than 10 percent off-road) typically with less than three (3) stops per mile. • Heavy Service (Vocational) covers vehicles with more than 10 percent off-road OR moderate to frequent starts/stops typically with more than three (3) stops per mile.
• Off-Highway Service covers lower mileage operations. Vehicles are not typically licensed for highway use. • The standard aftermarket warranty for WABCO products - including WABCO Original parts, WABCO Reman Solutions, ProVia quality aftermarket parts and WABCO retrofit solutions - is one year, parts only from in-service date when purchased from ZF distributor networks or its affiliates and/or subsidiaries.
MODEL YEAR 2021 VEHICLES
How to Read Warranty Coverage (Example)
Number of Years Mileage (in thousands) Unl=Unlimited P=Parts Only P&L=Parts & Labor 3 300 P
WARRANTY - MODEL YEAR 2021 VEHICLES
¹ ZF and WABCO branded components.
2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve.
• Aerial Ladder Truck
• Aerial Platform
• Ambulance
• Auto Hauler
• Beverage Truck
• Bulk Hauler
• Chip Hauler (Truck)
• Cross Country Coach
• Doubles
• Flatbed
• Front Engine Commercial
Chassis
• Front Engine Integral
Coach
• General Freight
• Grain Hauler
• Intercity Coach
• Intermodal Chassis
• Livestock Hauler
• Meat Packer
• Moving Van
• Municipal Truck
• Pipe Hauler
• Platform Auto Hauler
• Pumper
• Rear Engine Integral Coach
• Recreational Vehicles
• Refrigerated Freight
• School Bus
• Stake Truck
• Tanker
• Tanker Truck
• Triples
• Tour Bus
• Wrecker
LINEHAUL/GENERAL SERVICE VEHICLES
LINEHAUL/GENERAL SERVICE WARRANTY INFORMATION
LINEHAUL TYPICALLY IS
• High mileage operation (over 60,000 miles/year)
• Well maintained major highways of concrete or
asphalt construction
GENERAL SERVICE TYPICALLY IS
• Moderate mileage operations (less than 60,000 miles/year) • Well maintained public roads (less than 10% off-road) • Less than three (3) stops per mile
WABCO Components1
Air Management
Air Brake Valves
1/100/P<railer Lift Axle Control Valve
Trailer Control Line Filter3
Air Compressors (ALL)2 2/200/P&L
Air Dryers (ALL) 3/300/P&L
Aerodynamics
OptiFlow® TrailerSkirt 2/UnU/P
OptiFlow® Trailer Tail and AutoTail 2/UnI/P
Braking Systems
ABS (Anti-Lock Braking System) Air
3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic
Electronic Braking System (EBS)
Electronic Stability Control (ESC)
Roll Stability Control (RSS)
Trailer Roll Stability Support (RSS)
Trailer ABS (Anti-Lock Braking System)
3 Driveline Suspension Control
Clutch Controls 2/200/P&L
Leveling Valves
1/100/P&L
OptiRide® Automated Manual Transmission (AMT)
OptiRide® Electronically Controlled Air Suspension
(ECAS) 3/300/P&L
WABCO Components1 (cont.)
Safety
OnGuardACTIVE®
3/300/P&L
OnLane®
OnLaneALERT®
OnSide®
Trailer SafeStart™
Trailer TailGUARD™
Telematics
TrailerCAST™ Telematics Device 3/300/P&L
Wheel End Solutions
EasyFit™ Slack Adjuster 6/600/P
MAXXUS™ Truck Air Disc Brake 5/500/P&L
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 17 and 19 Air Disc Brake 2/Unl/P and
1/Unl/L
Pan 22 Air Disc Brake 5/500/P and 1/L
TRISTOP™ D Actuator w/ IBV or IRB 6/600/P
TRISTOP™ D Actuator 3/300/P
UNISTOP™ Actuator 2/200/P
Trailer MAXX22T™ Air Disc Brake 5/500/P and 1/L
1 ZF and WABCO branded components. 2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve.
WABCO Components1
Air Management
Air Brake Valves
1/100/P&L
Air Compressors (ALL)2
Air Dryers (ALL)
Trailer Control Line Filter3
Braking Systems
ABS (Anti-Lock Braking System) Air 3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic 2/200/P&L
Electronic Braking System (EBS)
3/300/P&L
Electronic Stability Control (ESC)
Trailer ABS Valve3
Roll Stability Control (RSS)
Trailer Roll Stability Support (RSS)
Driveline Suspension Control
OptiRide® Electronically Controlled Air Suspension
(ECAS) 2/200/P&L
Leveling Valves 1/100/P&L
Clutch Controls 2/200/P&L
Safety
OnGuardACTIVE®
3/300/P&L
OnLane®
OnLaneALERT®
OnSide®
Trailer SafeStart™
Trailer TailGUARD™
Telematics
TrailerCAST™ Telematics Device 3/300/P&L
Wheel End Solutions
EasyFit™ Slack Adjuster 2/200/P
MAXXUS™ Air Disc Brake 1/Unl/P&L
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 22, 19 and 17 Air Disc Brake 1/Unl/P&L
Trailer MAXX22T™ 1/Unl/P&L
TRISTOP™ D Actuator w/ IBV 3/Unl/P
TRISTOP™ D Actuator 2/200/P
UNISTOP™ Actuator 1/100/P
• Airport Rescue Fire (ARF)
• Airport Shuttle
• Asphalt Truck
• Block Truck
• Bottom Dump Trailer
Combination
• Cementing Vehicle
• City Bus
• Commercial Pick-Up
• Concrete Pumper
• Construction Material Hauler
• Crash Fire Rescue (CFR)
• Mixer
• Demolition
• Drill Rig
• Dump
• Emergency Service
• Equipment Hauling
• Flatbed Trailer Hauler
• Flatbed Truck
• Fracturing Truck
• Front Loader
• Geophysical Exploration
• Hopper Trailer Combinations
• Landscaping Truck
• Liquid Waste Hauler
• Log Hauling
• Lowboy
• Michigan Special
Gravel Trains
• Michigan Special
Log Hauler
• Michigan Special
Steel Hauler
• Michigan Special
Waste Vehicle
• Municipal Dump
• Newspaper Delivery
• Package Delivery
• Pick-up and Delivery
• Rapid Intervention
Vehicle (RIV)
• Rear Loader
• Recycling Truck
• Residential Pick-Up/Waste
• Rigging Truck
• Roll-Off
• Scrap Truck
• Semi-End Dump
• Sewer/Septic Vacuum
• Shuttle Bus
• Side Loader
• Snowplow/Snowblower
• Steel Hauling
• Tanker
• Tank Truck
• Tractors with Pole Trailers
• Tractor/Trailer with Jeeps
• Transfer Dump
• Transfer Vehicle
• Transit Bus
• Trolley
• Utility Truck
• Winch Truck
HEAVY SERVICE VEHICLES
HEAVY SERVICE (VOCATIONAL) WARRANTY INFORMATION
HEAVY SERVICE TYPICALLY IS
• On/Off road vocations (10% or more off-road) OR
• Moderate to frequent starts/stops typically more than three (3) stops per mile
WARRANTY - MODEL YEAR 2021 VEHICLES
INDUSTRIAL AND OFF-HIGHWAY SERVICE
TYPICALLY IS
• Low mileage operation3
• Vehicles are not typically licensed for highway use
¹ ZF and WABCO branded components. 2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 Equivalent hours of service limit: 2,000 hours for all components.
INDUSTRIAL/OFF-HIGHWAY SERVICE WARRANTY INFORMATION
WABCO Components1
Air Management
Air Brake Valves
2/Unl/PAir Compressors (ALL)2
Air Dryers (ALL)
Brake Actuation
Air/Hydraulic Actuators
2/Unl/P
Master Cylinders
Remote Actuators
Slave and Wheel Cylinders
Two Fluid Actuators
Brake Locks
Brake Locks (ALL)
2/Unl/PElectric Brake Locks
Lever Locks
Braking Systems
ABS (Anti-Lock Braking System) Air
1/100/P&L
ABS (Anti-Lock Braking System) Hydraulic
Driveline Suspension Control
Clutch Controls
1/100/P&L
Leveling Valves
Electrohydraulics & Controls
Electronic Pedals
2/Unl/PElectrohydraulic Brake Valves (EBV)
Pressure Switches
Hydraulic Braking Solutions
Accumulator Charging Valves
2/Unl/PHydraulic Throttle Controls and Switches
Modulating Brake Valves
Wheel End Solutions
EasyFit™ Slack Adjuster 2/200/P
Caliper Disc Brakes 2/Unl/P
MAXXUS™ Air Disc Brake 1/Unl/P&L
Multiple Disc Brakes 2/Unl/P
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 22, 19 and 17 Air Disc Brake 1/Unl/P&L
TRISTOP™ D Actuator w/ IBV 3/Unl/P
TRISTOP™ D Actuator 2/200/P
UNISTOP™ Actuator 1/100/P
Market Common Application Types
Agriculture
Fertilizer Spreader, Tractor, Heavy Duty Ag
Trailers, Harvester, Sprayer, Skid Loader, Silage
Bagger, Slurry Wagons, Grain Cart
Airport Support
Pushback Tractor, Towing Tugs, Aircraft Tow
Tractor, Refueling Trucks, Food Service Trucks,
Baggage Tractors, De-Icing Equipment,
Runway Clearing Equipment
Construction
All-Terrain Crane, Rough Terrain Crane,
Excavator, Compactor, Wheel Loader, Road
Roller, Motor Grader, Articulated Dump Truck,
Rubber Tire Road Roller, Backhoe Loaders,
Haul Trucks, Scraper Rough Terrain Forklifts,
Trenchers, Drills
Forestry Logging Forwarder, Kidder, Loaders, Yard
Forklifts, Harvesters Fellers
Material Handling
Port Tractor, Rail Yard Spotter, Stevedoring
Tractor, Trailer Spotter, Yard Jockey, Scissor
Lift, Straddle Carrier, Manlift, Forklift, Boom Lift
Telebandlers, Aerial Work Platforms
Mining
Specialized Mining, Excavator, Haul Truck,
Underground Loader, Service Trucks, Wheel
Loaders, Scrapers, Load Haul Dumps,
Personnel Transports, Bolters, Scalers
Municipal
Street Sweeper, Utility Tractor, Utility Trucks,
Tree Trimmers, Dump Trucks, Tow Trucks, Flat
Bed Trucks, Winch Applications
Oil & Gas
Fracturing Trailer, Injecter Heads, Top Drives,
Jack/Lift Boats, Wireline Trucks, Load-On /
Load-Off
Rail
Railcar Mover, Track Layers, Grinders, Platform
Crane, Locomotive Railcars, Ballast Equipment,
Winch Applications
ABS, ELECTRONIC STABILITY CONTROL (ESC),
ROLL STABILITY CONTROL (RSC), OPTIRIDE®,
ONGUARD® AND ONLANE®, COLLECTIVELY
“ELECTRONICS”
Failure of electronic components due to overvoltage
condition, improper grounding, electrostatic discharge
(ESD), improper shielding, electromagnetic interference (EMI), or other wiring or installation issues. Malfunctions and failure codes caused by other electronic subsystem failures (data bus, engine, transmission, dashboard, etc.)
HYDRAULIC COMPONENTS
For certain components, brake fluid DOT3 or DOT4 is
used as the operating medium. Use of any other fluid will void all warranties associated with that component. For hydraulic braking applications the brake fluid is considered a maintenance item. Maintenance intervals are listed in TB- 1367.
COVERAGE LIMITATIONS
PRODUCT DESCRIPTION
ALL PRODUCTS
Any claim beyond 60 days from date of repair will not be accepted or honored under this warranty program.
Products purchased on an incomplete vehicle (glider) are limited to one year, 1/Unl/P .
For vehicles that operate full- or part-time outside of the United States and Canada, a 1-Year/Unlimited Miles parts only (1/Unl/P) will apply.
TOOLBOX PLUS™ DIAGNOSTIC SOFTWARE
Proper diagnostics of WABCO Electronics may require the latest version of TOOLBOX PLUS™. Additional labor due
to use of an outdated version of TOOLBOX™ software
and/or the time to purchase or install the latest version of TOOLBOX PLUS™ are not covered under product
warranty.
TERMS AND CONDITIONS
COVERAGE EXCLUSIONS
PRODUCT DESCRIPTION
ALL PRODUCTS
This Warranty shall not apply to the following, but not limited to: (1) damage to the product or its component
parts caused by incorrect use, installation, maintenance or repair, including without limitation (a) improper fit of mating components or brackets, damaged threads, cut, broken,
chafed, pinched or otherwise damaged wiring (sensors,
harnesses and connectors), (b) sensors damaged during
removal when seized in block, or associated with sensor adjustments/ alignments, and (c) damage resulting from the use or installation of non-genuine WABCO components or
materials; (2) damage to the product, its component parts, or diminished product or component part performance due to incorrect operation, deviation from approved conditions or misapplication; (3) any unauthorized disassembly of the product or its component parts including without limitation (a) obliterated, defaced or missing WABCO or WABCO
name plate, serial numbers or label identifying the device as
a ZF product or WABCO component, (b) changes to sealed
adjusting screws, and (c) opening or attempted repair of non-serviceable components; (4) malfunction
of the component d ue to internal cont amination of t he vehicle system including without limitation (a) water and other contamination damage that is due to the use of a
non-genuine air dryer cartridge or (b) valve failures due to contamination in air system, (5) complaints associated
with noise, (6) damage resulting from corrosion (including oxidation of electrical devices and connections).
AIR DRYERS
Mounting brackets (see vehicle OEM). Desiccant cartridge housing only.
AIR SYSTEM COMPONENTS
Normal wear items; Gladhand seals, dash valve knobs,
valve actuation handles, treadles, pedals.
WARRANTY - MODEL YEAR 2021 VEHICLES
(1) What is Covered by this Commercial Warranty?
ZF CV Systems North America LLC and its North American
subsidiaries and affiliates (ZF) warrant to the owner (“Owner”) that the components listed in this publication, which have been installed by an Original Equipment Manufacturer (“OEM”) as original equipment will be free from defects in material and workmanship. This warranty coverage begins from the original in-service date to the limits provided and runs concurrently with any warranties provided by OEMs and/or any distribution agreements and/or any service contracts that cover the components listed in this publication, if any. If the components listed in this publication are covered by an OEM warranty and/or service contract, then the OEM’s warranty and/ or service contract shall supersede ZF’s warranty and Owner shall comply with all OEM’s warranty and/or service contract requirements for claims under such OEM’s warranty and/or service contract until those agreements expire.
Once those agreements expire and provided the ZF warranty has not expired under the terms stated above, the ZF warranty will be in effect until its expiration date.
Warranty coverage ends at the expiration of the applicable time period from the date of vehicle purchase by the first Owner, or, the applicable mileage limitation, whichever occurs first. Duration of coverage varies by component and vocation as detailed previously in this publication.
Some components are warranted for parts only and the Owner must pay any labor costs associated with the repair or replacement of the component. Other components are warranted for both parts and reasonable labor to repair or replace the subject component.
Additional diagnostic time due to use of an outdated version of TOOLBOX™, time to purchase or install latest version of TOOLBOX™ are the responsibility of the authorized ZF distributor networks and are not covered under product warranty. Components installed as replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty. (2) Designation of Vocational Use Required. To obtain warranty coverage, each Owner must notify ZF through the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the WABCO components have been incorporated prior to the vehicle in- service date. This notification may be accomplished by registering the vehicle through your OEM new truck and/or trailer dealer or with ZF directly. Failure to notify ZF of (I) the intended vocational use of the vehicle or (II) a change in vocational use from that which was originally designated, will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial in- service date. A second Owner and each subsequent Owner
must
also notify ZF as to the intended vocational use of the vehicle. This notification can be sent directly to ZF or through
the OEM new truck and/or trailer dealer. The duration and mileage coverage of this warranty cannot exceed the coverage extended to the first Owner after his or her initial designation of vocational use. Coverage under ZF’
s warranty requires that the application of
products be properly approved pursuant to OEM and ZF, approvals. (3) What is the Cost of this Warranty? There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty? In addition to the items listed on "Coverage Exclusions," this warranty does not cover normal wear and tear, or service items; nor does it cover a component that fails, malfunctions or is damaged as a result of (a) improper handling, storage, installation, adjustment, repair or modification including the use of unauthorized attachments or changes or modification in the vehicle’s configuration, usage, or vocation from that which was originally approved by ZF, (b) accident, fire or other casualty, natural disaster, road debris, negligence, misuse, abuse, or improper use (including loading beyond the specified maximum vehicle weight or altering engine power settings to exceed the brake system capacity),
or (c) improper or insufficient maintenance (including deviation from maintenance intervals, approved lubricants, or lube levels). This warranty does not cover any component or part that is not sold by ZF. (5) To obtain service. If the owner discovers within the applicable coverage period a defect in material or workmanship, the Owner must promptly give notice to either ZF or the dealer from which the vehicle was purchased. To obtain service, the vehicle must be taken to any participating OEM dealer or ZF distributor networks' servicer. The dealer or ZF authorized servicer will inspect the vehicle and contact ZF for an evaluation of the claim. When authorized by ZF, the dealer or ZF authorized servicer will repair or replace during the term of this warranty any defective WABCO component covered by this warranty. (6) Disclaimer of Warranty and Limitation of remedies. TO THE MAXIMUM
EXTENT PERMITTED BY LAW, THE LIMITED WARRANTY SET
FORTH HEREIN IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED, ARISING BY OPERATION OF
LAW OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY
IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE AND/OR WARRANTY FOR HIDDEN OR
LATENT DEFECTS, AND IN NO EVENT WILL ZF OR ANY OF ITS
AFFILIATES BE LIABLE FOR DIRECT, INDIRECT, INCIDENTAL,
PROGRESSIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES OF ANY
KIND.
TERMS AND CONDITIONS
(7) Legal action. Any legal action or claim arising from or related to this Warranty, in contract or otherwise, must be commenced within one year from the accrual of that cause of action, or be barred forever. Any dispute arising in connection with this agreement shall be governed by and construed according to the laws of the State of Michigan and be brought, heard and determined exclusively in either the Circuit Court for the County of Oakland, State of Michigan or the United States District Court for the Eastern District of Michigan. The parties stipulate that the referenced venues are convenient.
(8) Remedy. The exclusive remedy under this warranty shall be the repair or replacement of the defective component at ZF's option. ZF reserves the right to require that all applicable covered components are available and/or returned to ZF
for review
and evaluation. THE MAXIMUM LIABILITY, IF ANY, OF ZF FOR ALL
DAMAGES, INCLUDING WITHOUT LIMITATION CONTRACT
DAMAGES, BREACH OF WARRANTY, NEGLIGENCE, STRICT
LIABILITY, OR OTHER TORT, IS LIMITED TO AN AMOUNT NOT TO EXCEED THE PURCHASE PRICE OF THE PRODUCT and where
indicated in the product and application warranty information above, the inclusion of labor is limited to the standard repair time. THE
PARTIES ACKNOWLEDGE AND AGREE THAT THE LIMITATION
OF DAMAGES PROVISION SET FORTH IN THIS PARAGRAPH
SURVIVES BETWEEN THE ORIGINAL END USER AND ZF EVEN IF
THE EXCLUSIVE REMEDY SET FORTH ABOVE IS DEEMED TO FAIL
OF ITS ESSENTIAL PURPOSE. ZF may change the design or make improvements to its Products without incurring any warranty obligation for previously manufactured Product .
(9) Entire Agreement. This is the entire agreement between ZF and the Owner about warranty and no, ZF employee, or dealer is authorized to make any additional warranty on behalf of ZF unless in writing and signed by an authorized representative of ZF.
About ZF Friedrichshafen AG
ZF is a global technology company and supplies systems for passenger cars, commercial vehicles and industrial technology, enabling the next generation of mobility. ZF allows vehicles to see, think and act. In the four technology domains Vehicle Motion Control, Integrated Safety, Automated Driving, and Electric Mobility, ZF offers comprehensive solutions for established vehicle manufacturers and newly emerging transport and mobility service providers. ZF electrifies different kinds of vehicles. With its products, the company contributes to reducing emissions and protecting the climate.
ZF, which acquired WABCO Holdings Inc. on May 29, 2020, now has 160,000 employees worldwide with approximately 260 locations in 41 countries. In 2019, the two then-independent companies achieved sales of €36.5 billion (ZF) and $3.4 billion (WABCO). For more information, visit: www.wabco-na.com
© 2021
ZF CV Systems North America LLC - All rights reserved - SP1375 / 2.2021 For further product details contact your distributor or the WABCO Customer Care Center at 855-228-3203.
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0012
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.
This warranty applies only to the cab tubular support and mounting structures and other structural components of the cab of the vehicle model, as identified in the Pierce
specifications for the Fire and Rescue Apparatus.
This warranty does not apply to damage caused by corrosion.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:
Fire and Rescue Apparatus
Coverage:
Ten (10) Year Structural Integrity
Custom Cab
Ten (10) Years
- or -
100,000 Miles
Warranty Period
Ends After:
The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:
The Pierce Custom Cab shall be free from structural failures caused by defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
Fire and Rescue Apparatus
Coverage:
Ten (10) Year Pro-Rated Paint and Corrosion
Cab
Ten (10) YearsWarranty Period
Ends After:
The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:
Exterior surfaces of the cab painted by Pierce shall be free from blistering, peeling, corrosion or any other adhesion defect caused by defective manufacturing methods or paint material selection.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0055
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.
This limited warranty is applicable to the vehicle in the following percentage costs of warranty repair, if any:
Topcoat Durability & Appearance: Gloss, Color Retention & Cracking
0-72 months 100%
73-96 months 50%
97-120 months 25%
Integrity of Coating System: Adhesion, Blistering/Bubbling 0-36 months 100%
37-84 months 50%
85-120 months 25%
Corrosion: Dissimilar Metal and Crevice
0-36 months 100%
37-48 months 50%
49-72 months 25%
73-120 months 10%
Corrosion Perforation
0-120 months 100%
This limited warranty applies only to exterior paint. Paint on the vehicle's interior is warranted only under the Pierce Basic One Year Limited Warranty.
Items not covered by this warranty include:
(a) Damage from lack of maintenance and cleaning (proper cleaning and maintenance procedures are detailed in the Pierce operation and maintenance manual).
(b) UV paint fade.
(c) Any cab not manufactured by Pierce.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0014
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.
This limited warranty applies to all of the control modules for the Command Zone system, including the full color graphic displays. Related wire harnesses, cables and connectors are not covered under this limited warranty and are instead covered under the Pierce One Year Basic Apparatus Limited Warranty.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:
Fire and Rescue Apparatus
Coverage:
Five (5) Year Material and Workmanship
Command Zone Electronics
Five (5) YearsWarranty Period
Ends After:
The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:
Command Zone control modules shall be free from failures caused by defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 1/11/2011 WA0188
1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL
OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,
INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY
WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.
This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.
THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE
TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.
This limited warranty does not apply to related wire
harnesses, cables, and connectors, which are covered by the Pierce one (1) year basic apparatus limited warranty.
Conditions and
Exclusions:
See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:
Fire and Rescue Apparatus
Coverage:
54 Months Material and Workmanship
Camera System
Fifty - Four (54) monthsWarranty Period
Ends After:
The date of delivery.Warranty Begins:
This limited warranty covers repairs to correct any defect related to materials or workmanship of the Sharpvision
camera system installed on the apparatus occuring during th e
warranty period.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;
4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,
INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,
WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW
OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY
PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS
THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,
REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.
If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.
Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
3. BUYER'S EXCLUSIVE REMEDY.
NEW PRODUCT WARRANTY
PARTICIPATING OEM SALES
DISTRIBUTOR SALES
LIMITED WARRANTY ON NEW ALLISON AUTOMATIC TRANSMISSIONS
USED IN EMERGENCY VEHICLE APPLICATIONS
Allison Transmission will provide for repairs or replacement, at its option, during the warranty period of each new Allison transmission listed below that is installed in an Emergency Vehicle in accordance with the following te rms, conditions, and limitations.
WHAT IS COVERED
WARRANTY APPLIES — This warranty is for new Allison transmission models listed below installed in an Emergency Vehicle and is provided to the original and any subsequent owner(s) of the vehicle during the warranty period. REPAIRS COVERED — The warranty covers repairs or replacement, at Allison Transmission’s option, to correct any transmission malfunction resulting from defects in material or workmanship occurring during the warranty period. Needed repairs or replacements will be performed using the method Allison Transmission determines most appropriate under the circumstances. TOWING — Towing is covered to the nearest Allison Transmission Distributor or authorized Dealer only when necessary to prevent further damage to your transmission.
PAYMENT TERMS — Warranty repairs, including parts and labor, will be covered per the schedule shown in the chart contained in section “APPLICABLE MODELS, WARRANTY LIMITATIONS, AND ADJUSTMENT SCHEDULE.” OBTAINING REPAIRS — To obtain warranty repairs, take the vehicle to any Allison Transmission Distributor or authorized Dealer within a reasonable amount of time and request the needed repairs. A reasonable amount of time must be allowed for the Distributor or Dealer to perform necessary repairs.
TRANSMISSION REMOVAL AND REINSTALLATION — Labor costs for the removal and re-installation of the transmission, when necessary to make a warranty repair, are covered by this warranty. WARRANTY PERIOD — The warranty period for all coverages shall begin on the date the transmission is delivered to the first retail purchaser, with the following exception:
Demonstration Service - A transmission in a new truck or bus may be demonstrated to a total of 5000 miles (8000 kilometers).
If the vehicle is within this limit when sold to a retail purchaser, the warranty start date is the date of purchase. Normal warranty services are applicable to the demonstrating Dealer. Should the truck or bus be sold to a retail purchaser after these limits are reached, the warranty period will begin on the date the vehicle was first placed in demonstration service and the purchaser will be entitled to the remaining warranty.
APPLICABLE MODELS, WARRANTY LIMITATIONS, AND ADJUSTMENT SCHEDULE
WARRANTY LIMITATIONS
(Whichever occurs first)
ADJUSTMENT CHARGE TO BE
PAID BY THE CUSTOMER APPLICABLE
MODELS
Months
Transmission Miles
Or Kilometers Parts Labor
MT, MD
3000, 3200, 3500, 3700 0–24 No Limit No Charge No Charge HT with Hydraulic Controls 0–24 No Limit No Charge No Charge AT, 1000 Series, 2000 Series,
2400 Series 0–36 No Limit No Charge No Charge
HT with Electronic Controls 0–60 No Limit No Charge No Charge HD
1000 EVS, 2100 EVS, 2200 EVS
2350 EVS, 2500 EVS, 2550 EVS,
3000 EVS, 3500 EVS, 4000,
4000 EVS, 4500, 4500 EVS, 4700,
4700 EVS, 4800, 4800 EVS
0–60 No Limit No Charge No Charge