Cities Index.
Attachment 2

Burbank City Council
January 24, 2023

Document
Attachment 2
Meeting
January 24, 2023
Body
Burbank City Council
Pages
222
Original file
9.3 MB
Text extracted from the city's file for reading and search. Open the original on burbank.granicus.com. That file is the official record.

ATTACHMENT 2
A2-200
Allegro 3™ Rugged Handheld
Juniper Systems, Inc. Logan, Utah, USA
Phone: 435.753.1881
Email: [email protected]
Juniper Systems Ltd. Bromsgrove, UK
Phone: +44 (0) 1527 870773
Email: [email protected]
www.junipersys.com

PROCESSOR
• 1.2GHz quad-core ARM Cortex A9
i.MX6 processor

OPERATING SYSTEM AND SOFTWARE
• Android 7.1 AOSP
• Multiple languages (English, French, Spanish,
German, Portuguese)

MEMORY AND DATA STORAGE
• 2GB RAM
• 16GB flash storage
• User-accessible micro SD/SDXC slot

DISPLAY
• Active viewing area: 4.3” (109 mm) WVGA
LCD TFT (800x480)
• High visibility backlit LCD
• Portrait or landscape orientation

TOUCHSCREEN
• Projected capacitive touch interface
“optically bonded” to display for increased
visibility
• Chemically-strengthened glass
• Scratch-resistant screen

KEYBOARD
• Adjustable LED backlit keys
• Numeric keypad (6 user-reassignable)
• OEM configurable/customizable
PORTS
• COM1, RS-232C 9-pin D connector with
5VDC power output on pin 9 software-
enabled
• USB host (Full A), USB client (Micro B)
• 12, 24VDC input, 10-36V unregulated
• 3.5 mm audio jack, supports speaker/
microphone or stereo output (pin detect)
• I/O module OEM configurable/customizable

BATTERY
• Intelligent Li-Ion battery 3.6VDC @
12000mAh, 42.2Whr
• Operates for up to 20 hours on one charge
• Charges in 5.5 hours
• Battery easily changeable in field
• Optimized for excellent performance in cold
temperatures

PHYSICAL
• Size, Standard models: 3.6” w x 7.25” l x 1.5” d
(91 mm x 184 mm x 38 mm)
• Weight: 1.3 lbs (590 g), with battery
• Durable hardened plastic in a shear-proof
and shock-resistant design
• Strong chemical resistance
• Comfortable, wide hand strap
• Easy-to-grip, impact-absorbing bumpers
JUNIPER RUGGED™
• IP68 waterproof and dustproof 1.4m for 30
min)
• Operating temperature: –22F to 140F (–30C
to 60C)
• Storage temperature: –22F to 158F (–30C to
70C)
• Shockproof: multiple drops from 5’ (1.5 m)
onto concrete
• MIL-STD-810G test procedures: Method
500.5 Low Pressure (Altitude); Method
501.5 High Temperature; Method 502.5 Low
Temperature; Method 503.5 Temperature
Shock; Method 506.5 Rain; Method 507.5
Humidity; Method 510.5 Sand and Dust;
Method 512.5 Immersion; Method 514.6
Vibration; Method 516.6 Shock

WIRELESS CONNECTIVITY OPTIONS
• Bluetooth ® wireless technology, 4.2 BR/BDR/
BLE “Smart Ready,” Class 1.5, range greater
than 100 feet (30m)
• Wi-Fi ® 8 02.11b/g/n
CAMERA
• 5MP resolution with autofocus and LED
illuminator + video capture
• Embed photo with date, time, and GPS
position

GPS/GNSS (GEO MODELS)
• High-sensitivity GPS, GLONASS, Galileo,
BeiDou, QZSS, SBAS receiver
• User settings for enhanced performance
under canopy
• Accuracy: SBAS 2 meters; autonomous
5 meters
• NMEA-0183 ver. 4.0 output
• 72 channel u-blox M8 engine
• Concurrent GNSS constellation resolution
BARCODE 1D/2D IMAGER (BC MODELS)
• Built-in barcode imager and decoder
• Symbologies: all common 1D and 2D
(PDF417, MicroPDF417, Composite, RSS, TLC-
39, Data matrix, QR code, Micro QR code,
Aztec, MaxiCode, Postal codes, etc.)
• Programmable trigger buttons
• Visible aiming crosshair with low-light
illumination
• Barcode Connector ™ Utility, wedge and
configuration, SDK support available

CERTIFICATIONS AND STANDARDS
• FCC Class B
• CE Marking (applicable EMC, R&TTE, and
LVD directives)
• Industry Canada
• EN60950 Safety
• Optional Class I, II, III Division 2 for hazardous
locations

STANDARD ACCESSORIES
• 12000mAh battery
• AC wall charger with international plug kit
• Micro USB client sync cable
• Quick Start Guide
• Ultra-wide hand strap
• Shipping box
• Screwdriver
• Stylus with tether
• 2-year warranty
© Copyright 1/19 Juniper Systems, Inc.

Specifications are subject to change without
notice. All trademarks are registered or
recognized by its respective owners.

Designed and manufactured in the United States, the Archer 3 Rugged Tablet is built to perform for years and years. The Archer product line has long been favored across several industries as the ultimate mobile data collection device. And with customization options available, it’s tough to beat this data collection powerhouse.

Page 200 ends

ATTACHMENT 2
A2-201

DATA SHEET
ADS-10017-01
CommandLink® II
Wireless Interface
Seamless Communication
The CommandLink® II wireless interface provides access to a complete suite of functional controls within a gas, water or electric SmartPoint® transceiver. This Bluetooth® enabled device, coupled with a handheld, performs activations, deactivation, meter reads, on demand reads and can also readily audit the water, gas, or electric SmartPoint module.

CommandLink II provides instant access to any SmartPoint module’s programmed and stored information. You can retrieve setup information, validate readings, and verify or reprogram settings for optimal performance.

The CommandLink II is a compact tool that is compatible with Sensus approved WIN mobile, WIN 10, Android and iOS programming devices.

FEATURES
Compact size
Rechargeable batteries included
Bluetooth enabled
Built-in antenna

BENEFITS
Interacts with SmartPoint water, gas, and
electric modules
Performs on-demand interrogation
Retrieves and reprograms settings

Page 201 ends

ATTACHMENT 2
A2-202
SENSUS | 637 Davis Drive | Morrisville, NC 27560 | 800.638.3748 ©2020 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either sensus.com/TC or 1-800-638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. The Sensus logo is a registered trademark of Sensus.

This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT.

FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED.

Xylem.com | Sensus.com
CommandLink® II
Wireless Interface
Specifications
Case High-impact, injection-molded plastic
Dimensions 4.7” L x 2.37” H x 2.41” W
Weight 16 oz.

Operating Temp. 32°F to 122°F
Shock Temp. -20°F to 103°F
Charging Temp. -32°F to 104°F
Relative Humidity 65 +/- 20%y
Dust Meets procedures IP5X (MIL-STD 810F),
Method 510.4
Warranty One year
Compliance Complies with FCC Part 15, 24, and 101.

Complies with Industry Canada ICES-003.

Safety Certification CAN/CSA C22.2 No. 62368-1:2014
UL 62368-1:2014
EN 62368-1:2014/A11:2017

Page 202 ends

ATTACHMENT 2
A2-203

DATA SHEET
ADS-10009-01
FlexNet M400B2 Base Station
Compact Point-to-Multipoint Base Station
The Sensus FlexNet® M400B2 Base Station offers a strategic communications option for public service providers with endpoints deployed in remote or densely populated areas.

The efficient transceiver can transmit and receive in a 200kHz band of spectrum. 200kHz enables more dedicated channels, resulting in higher network capacity, allowing more granular data and more channels of data. And the Sensus FlexNet communication network delivers double the transmit power of competitive systems over primary-use licensed spectrum – ensuring reliability for mission critical applications.

The tower-based architecture enables reliable communication of status and usage information with fewer access points than other network architectures. These compact, efficient base stations fit in space- constrained environments and require no air conditioning.

Licensed Radio Spectrum
In North America, FCC/IC protected primary-use spectrum avoids competition with other wireless services, interference from other radio devices and the risk of being taken over by emergency service providers Fewer Access Points
Our point-to-multipoint architecture directly connects base stations to endpoints over large geographic areas – greatly reducing the number of network backhaul connections as well as O&M costs
Resilient Network Design
Sensus Base Stations continue to provide real time data during outages and emergencies because of eight hour plus battery backup – enabling better workforce management and faster service restoration Small Footprint
Flexible pole or wall-mounting options enable strategic deployment with a discreet appearance
Industry Leading Security
Sensus has achieved GE/Wurldtech™ Achilles® communications certification for critical infrastructure security against cyber threats

FEATURES
GPS receiver for time synchronization
Duplexer for single antenna
IP-addressable power supply with hot-
swap capability
8-hour battery backup
Alarms and reporting capability
Backhaul via Ethernet/IP
Heated battery for cold weather environ-
ments
Modular construction for easy
serviceability

APPLICATIONS
Two-way Advanced Meter Infrastructure
(AMI)
Distribution Automation (DA)
Demand Response (DR)
Home Area Networks (HAN)
Sensus VantagePoint® Lighting Control

Page 203 ends

ATTACHMENT 2
A2-204
©2018 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either https://sensus.com/TC or 1-800-638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. The Sensus logo is a registered trademark of Sensus.

This document is for informational purposes only, and SENSUS MAKES NO EXPRESS W ARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED W ARRANTIES, INCLUDING

WITHOUT LIMITATION, W ARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY . ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED.
8601 Six Forks Rd, Ste 700
Raleigh, NC 27615
1-800-638-3748
sensus.com
FlexNet® M400B2 Base Station
Compact Point-to-Multipoint Base Station
Enclosures - Outdoor - Pole/Wall Mount
Height 22” (55.9 cm)
Width x Depth 22” (55.9 cm) x 10.5” (26.7 cm)
Capacity One transceiver
Temperature -40º to +122º F (-40º to +50º C)
Voltage 120 VAC
Battery backup 8 hours
NEMA rating 4
Air conditioned No
Properties
Receive bandwidth 200 KHz
Transceivers Single
Spectrum Licensed 900 MHz PCS/MAS
Duplexing Single transmit
Sixteen receivers - simultaneous/dedicated
Applications Single
Expandability No
Compatibility SNMP
FlexNet Requires RNI 3.x or newer

Page 204 ends

ATTACHMENT 2
A2-205
Sensus Base Station Protection Plan
The following information describes the features of the base station protection plan provided to FlexNet® communication network customers. The base station protection plan was created to provide customers assurance that their base stations are covered regardless of whether it is a maintenance issue or the need to be upgraded to meet minimum software and hardware operating requirements for Sensus products.

Participation and Coverage
Participation in the base station protection plan is strongly recommended. This recommendation is made so that all participating customers can benefit from this cost effective plan to meet support needs.

All customers are required to declare participation in this program at the time of the initial base station order. Customers will be required to purchase the base station protection plan in five (5) year increments. Customers will be issued a renewal notice approximately sixty (60) days prior to the expiration date for them to renew for a new five (5) year term. Invoices must be paid no later than thirty (30) days following the system anniversary date or the protection plan will be terminated. Customers who do not choose to renew during the renewal period cannot elect to participate once the renewal period has expired.

Coverage Terms
Sensus will repair or replace defective parts
Base stations will be upgraded to meet minimum requirements for operating Sensus products Protection plan includes labor in the repair, replacement or upgrades of base stations Access to technical support 24/7
Defective parts will be repaired or replaced within five (5) business days once Technical Service has determined that the base station is unusable and that no workaround is available Upgrades to base stations will be completed by Sensus or their representatives once it has been determined that the hardware or operating software requires an upgrade to meet minimum operating requirements for Sensus products
Includes base station re-certification, if required

Page 205 ends

ATTACHMENT 2
A2-206
Alternate Option
Because participation in this protection plan is not mandatory, there is an alternate option for customers who choose to not participate. The customer will be charged for any and all repair, replacement or upgrade related to hardware, software and labor. Standard rates for all hardware and services at the time of service will apply.

Further Information
If you would like further help or information concerning the protection plan, please contact your local Sensus representative, authorized distributor, or call 1-800 METER-IT (1-800-638-3748) Notes
Customers are responsible for monitoring hardware and software components of their FlexNet system and contacting Sensus when support is needed. The base station protection plan does not cover system monitoring on a continuous or ongoing basis Customer acknowledges that Sensus reserves the right to repair or replace malfunctioning equipment at its discretion and at Sensus choice of location – either at the customer site, Sensus manufacturing facility or other appropriate site determined by Sensus If Sensus becomes unable, either wholly or in part, by an event of Force Majeure, to fulfill its obligations under this agreement, the obligations affected by the event of the Force Majeure will be suspended during the continuance of that inability. The term “ Force Majeure” means events beyond the reasonable control of Sensus, including, but not limited to, acts of God, hurricane, flood, volcano, tsunami, tornado, storm, tempest, vandalism, illegal radio frequency interference, strikes, lockouts, or other industrial disturbances, unavailability of component parts of any goods provide hereunder, acts of public enemies, wars, blockades, insurrections, riots, epidemics, earthquakes, fires, restraints or prohibition by any court, board, department, commission or agency of the United Sates or any States, any arrests and restraints, civil disturbances and explosions. Furthermore, the above services and support do not apply to products or software which have been: installed improperly or in non-recommended installations. Tampered with; modified or repaired with parts or assemblies not certified in writing by Sensus, including without limitation, communications parts and assemblies; converted; altered; damaged; read by equipment not approved by Sensus; subject to misuse, improper storage, care, maintenance (including expired hardware and/or software maintenance) or improper periodic testing (collectively, “Exceptions” .) If the applicable product satisfies any of the above Exceptions, the customer shall pay for and/or reimburse Sensus for all expenses incurred by Sensus in the examination and/or repair or replacement of such products Does not include antenna, antenna cables or base station batteries Does not include costs associated with tower rental, electrical fees or site maintenance Does not include costs associated with purchase, maintenance or support of ancillary network equipment or network backhaul connection
Does not include adding additional base stations to assure network coverage and/or capacity Does not include upgrades for network capacity due to increased field devices or traffic requirements in the service territory

Page 206 ends

ATTACHMENT 2
A2-207
637 Davis Drive
Morrisville, NC 27560
+1-919-845-4000
sensus.com
©2020 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either sensus.com/TC or 1-800-638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. The Sensus logo is a registered trademark of Sensus.

This document is for informational purposes only, and SENSUS MAKES NO EXPRESS W ARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED W ARRANTIES, INCLUDING

WITHOUT LIMITATION, W ARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY . ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED.

Terms and Trademarks
“FlexNet base station” identifies the Sensus manufactured device consisting of one transceiver that receives readings from the SmartPoint® modules (either directly or via a repeater) by radio frequency and passes those reading to the RNI by TCP/IP backhaul communications. For clarity, FlexNet base stations include M400B2, M400DS, M400D and R100NA “SmartPoint” modules identifies the Sensus transmission devices installed on devices such as meters, distribution automation equipment and demand response devices located at end user premises that take the readings of the meters and transmit those readings by radio frequency to the relevant FlexNet base stations
“RNI” identifies the regional network interfaces consisting of hardware and software used to gather, store and report data collected by the FlexNet bse station from the SmartPoint modules “Field Devices” refers to the SmartPoint modules
“FlexWare Software” or “Sensus Software” identifies the Sensus RNI software or FlexNet base station software
“Updates” means releases of the software or hardware that constitute a minor improvement in functionality
“Upgrades” means release of the software or hardware which constitute a significant improvements in functionality or architecture of the software or hardware “Release” means both updates or upgrades
“AMI System” identifies the Sensus FlexNet Advanced Metering Infrastructure (AMI) system comprised of the SmartPoint modules, RF equipment, server hardware, software licenses, FCC licenses and other equipment provided to the customer hereunder. The AMI system included the foregoing, as provided by Sensus. The AMI system does not include goods, equipment, software, licenses or rights provided by a third party or parties to this agreement.

This base station protection plan is supplemental to Sensus’ published warranties available at www.sensus.com/tc. The goods and services outlined herein are valid upon Sensus’ receipt of payments within the specified timeline as defined within Sensus payment terms and conditions.

All products purchased and service performed are subject to Sensus’ terms of sale, available at either www.sensus.com/tc or 1-800-METER-IT. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer.

For additional information concerning you base station protection plan, please contact your local Sensus representative, authorized distributor, or call: 1-800-METER-IT (1-800-638-3748).

Page 207 ends

ATTACHMENT 2
A2-208

DATA SHEET
WDS-10061-02
SmartPoint 522M
Pit Set Module
The SmartPoint® 522M pit set module is a radio transceiver that provides water utilities inbound and outbound access to water measurement and ancillary device diagnostics via radio signal. The 522M is designed for submersible, pit-set environments.

TouchCoupler, Pulse, or Three Wire inline connection Options The SmartPoint 522M utilizes TouchCoupler, the patented Sensus inductive coupling communication platform, to interface with the encoded meter. With TouchCoupler, the 522M can connect to the meter using existing two wire AMR installations instead of requiring utilities to access the meter to install a new three-wire connection. In addition, the 522M offers an option to connect to pulse meters and an option for three wire configured meters that incorporate inline connectors. This results in a fast, efficient and reliable connection at minimal cost.

Operation
With its migratable, two-way communication ability, an M-Series SmartPoint module functions as a walk-by/drive-by endpoint, fixed-base endpoint, or combination of the two. This flexibility increases utility data collection capabilities and streamlines operations. The 522M receives input from the meter register and remotely sends data to a walk-by/drive-by or fixed-base collection device. The 522M easily migrates from walk-by/drive-by to fixed base by simply installing a Base Station.

In walk-by/drive-by mode, the 522M collects data and awaits an activation signal from the Vehicle Gateway Basestation (VGB) or Hand-Held Device (HHD). Upon signal receipt, it transmits readings, the meter identification number and any alarms.

As a fixed-base endpoint, the 522M interacts with one or more strategically placed Base Stations located in the utility service area. Top of the hour readings and other diagnostics are instantly forwarded to the Regional Network Interface (RNI)™ at time of transmission. The FlexNet® communication network provides unmatched reliability by using expansive tower receiver coverage of metering end points, data/message redundancy, failover backup provisions and operation on FCC primary use (unshared) RF spectrum.

Powerful Transmission, Flexible Platform
The SmartPoint 522M offers several advantages that control both deployment and lifetime operation costs. Its powerful, industry-leading two watt transmitter broadcasts over large distances and minimizes collection infrastructure. After the module is installed, its migratable, two-way system platform can be updated without requiring personnel to visit each meter and/or inconveniencing customers.

BENEFITS
Easily connects to TouchCoupler, Pulse,
or Three Wire configuration that supports
inline connectors
Easily receives input from either walk-by/
drive-by or fixed-base collection device
Minimizes both deployment and lifetime
operation costs
Minimizes new infrastructure investment
Compact installation that saves time,
space and money - without reducing
system performance
Delivers a fast, efficient and reliable
connection at minimal cost
Multiple connector options minimize
inventory requirements
Enables effective leak detection

Page 208 ends

ATTACHMENT 2
A2-209
SENSUS | 637 Davis Drive | Morrisville, NC 27560 | 800.638.3748 ©2022 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either sensus.com/TC or 1-800-638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. The Sensus logo is a registered trademark of Sensus.

This document is for informational purposes only, and SENSUS MAKES NO EXPRESS WARRANTIES IN THIS DOCUMENT.

FURTHERMORE, THERE ARE NO IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY. ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED.

Xylem.com | Sensus.com
SmartPoint 522M
Pit Set Module
Additional SmartPoint 522M Features
The 522M obtains hourly readings and can monitor continuous flow over a programmable period of time, alerting the utility to leak conditions. In addition, the 522M stores up to 840 consumption intervals (35 days of hourly consumption), providing the utility with the ability to extract detailed usage profiles for consumer information and dispute resolution.

SPECIFICATIONS
Service Pit set installation interfacing the utility meter to the Sensus FlexNet communication network. Unit requires 1.75” diameter hole in pit lid; fits pit lid thicknesses up to 1.75” Physical characteristics Width: 4.43” x Height: 5.09” x Depth: 3” Weight 1.0 lbs/16.0 oz
Color Black
Frequency range 900 – 950 MHz, 8000 channels X 6.25 kHz steps Modulation Proprietary Narrow Band
Memory Non-Volatile
Power Lithium Thionyl Chloride batteries
Approvals
US: FCC CFR 47: Part 24D, Part 101C, Part 15
Licensed operation
Canada: Industry Canada (IC) RSS-134, RSS-119
Operating temperature - 22° F to +185° F
- 30° C to + 85° C
Operation Single Port
Installation environment 100% condensing, water submersible Compatibility TouchCoupler, Pulse register with inline connector, and Three Wire register with inline connector.

Warranty 20 years – Based on six transmissions per day.

Refer to Sensus G-500 for full warranty details.

Page 209 ends

ATTACHMENT 2
A2-210

QUICK GUIDE
WQG-10021-07
510M/520M SmartPoint® Module
Water Meter and Ancillaries Compatibility Quick Guide
Sensus
Register Type Model Meter Type
ICE & ICE Opto All meters that accept
ICE & ICE Opto 3-wire.

Positive
Displacement,
Multi-jet,
Compound,
Turbine, Propeller,
Fire Service
OMNI™ T2, C2, F2, R2 Floating Ball
Technology
accuMAG™ accuMAG Mag
i PER L® iPERL Mag
Permalog Permalog+ Acoustic
Technology
Sensus®
Electronic
Register+™ and
E-Register
accuSTREAM, SR II Positive
Displacement
ally ally ally
Hydroverse Hydroverse Mag
Badger
Register Type Model Meter Type
ADE All meters that accept
ADE 3-wire and
TouchCoupler support,
Sensus Approved TR/
PL lead, up to 8 wheels.

Disc, Turbine,
Compound, Fire
Service
HR-E LCD All meters that accept
HR-E LCD 3-wire, up
to 8 wheels. Must be
at least SmartPoint
firmware version R1.2.1f
or higher.

Disc, Turbo Series,
Compound Series,
Combo Series, Fire
Service

E-SERIES
8 digits
All models with
firmware version 1.36.
3-wire**
Ultrasonic
Neptune
Register Type Model Meter Type
Proread
4 wheel
All meters that accept
Proread registers.
3-wire support
Positive
Displacement,
Turbine,
Compound, Fire
Service
E-coder with
TouchCoupler
4 wheel
All meters with
firmware version 01.02.

Manufactured after
1/2016.

Positive
Displacement,
Turbine,
Compound, Fire
Service
Proread
6 wheel
All meters that accept
Proread registers.
3-wire support
Positive
Displacement,
Turbine,
Compound, Fire
Service
E-coder
6 wheel
All meters that accept
E-coder registers.
3-wire support (Proread
protocol only)
Positive
Displacement,
Turbine,
Compound, Fire
Service
E-coder with
TouchCoupler
6 wheel
All meters with
firmware version 01.02.

Manufactured after
1/2016.

Positive
Displacement,
Turbine,
Compound, Fire
Service
E-coder
8 wheel
All meters that accept
E-coder registers.
3-wire support*
Positive
Displacement,
Turbine,
Compound, Fire
Service
E-coder with
TouchCoupler
8 wheel
All meters with
firmware version 01.02.

Manufactured after
1/2016.

Positive
Displacement,
Turbine,
Compound, Fire
Service
ProCoder
8 wheel
All meters with
firmware version 63.16.

Manufactured after
7/2018.

TouchCoupler and
3-wire**
Positive
Displacement,
Turbine,
Compound, Fire
Service
*SmartPoint firmware version 1.2 and above only
**SmartPoint firmware version 1.7 and above only

Page 210 ends

ATTACHMENT 2
A2-211
©2019 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either sensus.com/TC or 1-800-638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. The Sensus logo is a registered trademark of Sensus.

This document is for informational purposes only, and SENSUS MAKES NO EXPRESS W ARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED W ARRANTIES, INCLUDING

WITHOUT LIMITATION, W ARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY . ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED.
637 Davis Drive
Morrisville, NC 27560
1-800-638-3748
sensus.com
McCrometer
Register Type Model Meter Type
McCrometer
flowcom
FC100-00M
8 digits
3-wire reading.

Firmware 2.4.

Manufactured after
4/2015.

Propeller
ML255 battery
powered register
8 digits
3-wire reading only.

Firmware 5.09 or
greater.**
Propeller
ML Series
converter, AC
powered
8 digits
3-wire reading only.

Firmware 3.03 or
greater.**
Propeller
Master Meter
Register Type Model Meter Type
AccuLinx V1.19 All meters that accept
AccuLinx 3-wire and
TouchCoupler, Sensus
approved TR/PL lead.

Positive
Displacement
Sonata
8 digits
3-wire and
TouchCoupler,
firmware version 5.01
or greater.**
Ultrasonic
Octave
8 digits
3-wire only.** Ultrasonic
Diehl
Register Type Model Meter Type
Hydrus
8 digits
3-wire support only.**
Manufactured after
4/2018.

Ultrasonic
Kamstrup
Register Type Model Meter Type
flowIQ 2100
4, 6 and 8 wheel
3-wire reading. Version
C1.

Ultrasonic
flowIQ 2100
4, 6, and 8 wheel
3-wire and
TouchCoupler version
H1.**
Ultrasonic
Elster/Amco
Register Type Model Meter Type
Scancoder All meters that accept
Scancoder 3-wire
support (Sensus
protocol only).

Positive
Displacement,
Turbine, Multi-jet,
Bulk combo, Fire
service
InVision All meters that accept
InVision 3-wire support
(Sensus protocol only).

Positive
Displacement,
Turbine, Multi-jet,
Bulk combo, Fire
service
Hersey/Mueller Systems
Register Type Model Meter Type
Translator All meters that accept
Translator 3-wire and
TouchCoupler support,
Sensus approved TR/
PL lead.

Positive
Displacement, Mag
Zenner
Register Type Model Meter Type
PMN Nitro 01
4 wheel, 6 wheel
3-wire support only.

Manufactured after
8/2015.

Multi-jet
*SmartPoint firmware version 1.2 and above only
**SmartPoint firmware version 1.7 and above only

Page 211 ends

ATTACHMENT 2
A2-212
ADS-10003-04
Sensus Smart
Gateway
Features
Battery Powered
FlexNet enabled

Two (2) 4-20 mA analog
inputs and two (2) Form A
digital inputs per unit
15 minute data sampling re-
ported six (6) times per day
IP66 packaging for outdoor
applications
Mounting options for pipe
or wall mounting
Intrinsically Safe Class1
Div2
Maintenance free for the life
of the product
Interfaces with other sys-
tem infrastructure such as
CMEP and Multispeak
One (1) Year Warranty
Sensus Smart Gateway
Public service providers need timely data to make
critical and prompt decisions for their communities.

With the Sensus Smart Gateway, a battery-powered
sensor interface, utilities can connect to a variety
of applications in remote locations where there is
no power or land-based communications available.

Leveraging the FlexNet® communication network,
the user interface application empowers utilites
to remotely monitor pressures, temperatures,
levels, and switches. Alarms can be transmitted
and forwarded to utility systems or individuals
allowing for expedient resolution. Additionally, data
accumulation can be analyzed to develop new
insights into operational conditions.

With two (2) 4-20 mA analog inputs and two (2) Form
A digital inputs, the number of possible applications
makes the Smart Gateway a flexible, powerful and
cost effective device to gather information previously
too difficult to obtain.

Benefits
• Improves operational performance of the system.
• Enables proactive and preventative
maintenance.
• Enables quick resolution of equipment
failures.
• Decreases the need to deploy field crews.
• Maximizes return on investment.
• Supplements the existing SCADA system.
• Leverages the existing FlexNet network.
• No additional power line infrastructure is
necessary.
• Prevents theft and tampering, and improves
safety by communicating user-configured alarms.
• Facilitates flexible and scalable installation
through the system, including remote locations.
• Cost-effective option for extensive data
accumulation.

Applications
• Pressure readings
• Customer complaints resolution
• Hydraulic modeling
• Pressure modeling
• Fire flow testing
• Pressure reducing infrastructure monitoring
• Level measurements
• Tank/Aquifer/Reservoir monitoring
• Lift station monitoring
• Overflow monitoring
• Rain gauges
• Temperature readings
• Water and Gas Quality
• Security
• Vault doors
• Gates
• Valve positions
• Data Tracking
• Modeling
• Event responses
• Leak Detection

Page 212 ends

ATTACHMENT 2
A2-213
Physical Characteristics 6.4” W x 4”H x 2.8”D
Weight 1.5 lbs.

Color Grey
Frequency Range 900-950 MHz, 8000 channels x 6.25 kHz steps Modulation Proprietary Frequency Band
Power D Cell Lithium Thionyl Chloride battery
Operating Temperature -22 °F to +185 °F/-30 °C to 85 °C Installation Environment The Smart Gateway is designed for installation on a wall or pipe where it is not subject to water submergence.

Installation Kits Pipe/Wall-Mount
Wall-Mount Only
Optional Multi-Cable
Wiring Requirements See Installation Guide
Approvals United States Canada
FCC Title 47 CFR: Part 24D, Industry Canada (IC) RSS-134, Part 101C, Part 15 RSS-119
Specifications
Sensor Specifications
© 2015 Sensus. SmartPoint is a trademark of Sensus. FlexNet and the Sensus logo are registered trademarks of Sensus.

Call your sales
representative
to see for yourself.
8601 Six Forks Road
Suite 700
Raleigh, NC 27615
1-800-648-3748
www.sensus.com
Utility Type Pressure
Accuracy
Temperature
Accuracy
Water Level
Accuracy
Output
Settling
Time
Operating
Voltage
Current
Draw
Zero Offset
Water +/- 1.5% PSI +/-1 °F +/-2”
≤ 200 milli-
seconds ≥ 12.5 volts
2-Wire: ≤ 30
mA
3-Wire: ≤
100 mA
≤ 6% mA
Gas` +/- .25% PSI N/A N/A

Page 213 ends

ATTACHMENT 2
A2-214

DATA SHEET
EDS-10009-02
Stratus IQ™ Electricity Meter
Taking the Grid to Next-level Smart

FEATURES
Six energies and six demands
Four quadrant metering
Eight load profile channels
Expanded LCD with multiple enunciators
Tamper detection
Persistent real-time clock maintains time
for 24 hours following outage
Optical port

BENEFITS
C&I power in a residential meter
Software defined metrology for future
flexibility
Flexible two-way communication via the
FlexNet® Communication Network
FCC approved communication over
unshared, primary use licensed spectrum
Building upon the best-in-class Stratus® metering platform, the Stratus IQ combines grid edge intelligence with
precise energy measurement into one powerful package.

This meter was designed to provide utilities with the data visibility and control needed to quickly adapt to a rapidly evolving smart grid.

Software-defined metrology
Hardware constraints for measuring energy is now a thing of the past.

With the ability to make metrology adjustments over-the-air, utilities are prepared for whatever the future holds. Today, the Stratus IQ takes measurement to the next-level by gathering 8,000 samples per second for increased accuracy and flexibility.

C&I power in a residential meter
Four-quadrant metering is just the beginning. By simultaneously measuring real, apparent and reactive energy, the Stratus IQ gives utilities the competitive knowledge necessary to be more efficient in the generation and distribution of power.

Data is the name of the game
The Stratus IQ currently has eight channels of load profile data along with line-side and load-side voltage reporting. This insight gives utilities the concrete data needed to make educated decisions. No other meter on the market has this type of system visibility. In the future, the Stratus IQ will feature four data sets comprised of eight channels each for a total of 32 channels.

Details
kWh, kVAh, kVARh energy measurements
Demand and load profile with load limiting (current or demand) AES 256-bit encryption security
C12.19 utility industry end device ANSI Tables
Full net metering and primary metering
20-year Time-of-Use calendar
Patented temperature detection
Best-in-class power outage and restoration notification Voltage measurement and configurable alarm reporting
Remote ZigBee, radio and metrology firmware download
1 Wh internal and display resolution

Page 214 ends

ATTACHMENT 2
A2-215
©2019 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either sensus.com/TC or 1-800- 638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. The Sensus logo is a registered trademark of Sensus.

This document is for informational purposes only, and SENSUS MAKES NO EXPRESS W ARRANTIES IN THIS DOCUMENT. FURTHERMORE,

THERE ARE NO IMPLIED W ARRANTIES, INCLUDING WITHOUT LIMITATION, W ARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY . ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED. 8601 Six Forks Rd, Ste 700
Raleigh, NC 27615
1-800-638-3748
sensus.com
Stratus IQ™
Electricity Meter
Specifications
Forms 1S, 2S, 3S, 4S, 12S, 25S, 1SRD, 2SRD, 12SRD, 25SRD, 2SCL320 Power
Requirements
Voltage Rating: 120VAC and 240VAC
Frequency: 60 Hz
Accuracy Exceeds Accuracy Class 0.2 (ANSI C12.20-2015)
Burden Power Supply 1.2W / 6.7VA @240VAC; 1.1W / 3.0VA @120VAC Current circuit per phase <0.01W
Device Type FlexNet Device Type 96; Metrology Device Type 97, ZigBee Device Type 98 Model Stratus IQ with FlexNet only: IDTB005, FCC ID: SDBIDTB005, IC: 2220A-IDTB005 Stratus IQ with FlexNet & Zigbee: IDTB006, FCC ID: SDBIDTB006, IC: 2220A-IDTB006 Remote Disconnect Rating: 200A, 240 VAC, 60Hz, PF 0.75 lagging Endurance: Greater than 6000 cycles, 200A, 240 VAC, 60 Hz, PF 0.75 lagging Endurance: Greater than 30000 cycles at no load
Overload: 50 OPS, 300A, 240 VAC, 60 Hz, PF 0.75
Current Withstand: Per ANSI C12.1: 7,000 A Peak (5,000 Amps rms) 240 VAC, 60 Hz, for 6 cycles with normal operation after exposure; 12,000 Amps rms for 4 cycles with fail safe conditions after exposure Dimensions 6.95 in (17.65 cm) diameter; 5.06 in (12.86 cm) depth Industry Standards UL 2735 listed, ANSI C12.20 - 2015 (Class 0.2), ANSI C12.1 - 2014, ANSI C12.10 - 2011, ANSI C37.90.1 - 2002, FCC Part 15, Transient/Surge Suppression IEC 61000-4-4 - 2012 and IEEE C62.41.2 - 20002, Category B, Temperature Rise Specifications meets ANSI C12.1 Section 4.7.2.9, ANSI C12.18-R2006 (R2016).

Operating
Environment
Temperature -40° to +85° C under the cover
Humidity 0% to 95% non-condensing
Characteristic Data Starting Current: 20mA (for CL200); 9mA (for CL20) Hardware Options ZigBee, Remote disconnect

P4A
%
Hz
PF
A
B
C
D
E
F
G
A C
TEST
EOIALT120
240
1 2
3 4 5
6 7
LCD display
The data display is composed of LCD segments
arranged to display letters and digits. Typically, the
total kilowatt-hours are displayed in whole numbers;
the resolution may be selected at the time of order.

You can control the number of digits displayed, the
justification of the digits within the display, and the location of the decimal point. Key: 1 = source list number, 2 = meter communication, 3 = voltage, 4 = TOU indicators, 5 = data display
and disk simulator, 6 = energy quadrant indicator,
7 = energy type

Page 215 ends

ATTACHMENT 2
A2-216

DATA SHEET
EDS-10004-02
Aclara kV2c Electric Meter
Commercial & Industrial Meter with FlexNet®
SmartPoint® Module

FEATURES
Full meter programming and firmware
updates over the air
Customize advanced metering options
including kWh, kVArh & kVAh
4-quadrant measurements
Voltage and Current THD per phase, TDD
(Total Demand Distortion), Distortion
Power Factor, Distortion kVA, and
Distortion kVAh
Per phase AC instrumentation (amps,
volts, and frequency)
Programmable diagnostics for voltage
imbalance, distortion, current imbalance,
reversed polarity, high neutral current.

Tamper detection tools and installation
verification capabilities to automatically
catch errors, wiring changes, tampering,
and billing issues
Voltage sag and swell log

BENEFITS
Flexible two-way communication
via FlexNet network
FlexNet communications network
supports multiple applications
FlexNet communications network is FCC
approved for operation on an unshared
primary-use licensed spectrum
Overview
Aclara’s premier commercial and industrial kV2c meter family has become even more powerful. The Gen 5 kV2c meter is now internally equipped with a Sensus SmartPoint module, giving utilities the power and performance of the FlexNet Communications Network coupled with revenue grade metering functionality and advanced power quality monitoring.

The kV2c meter moves beyond revenue metering to real time instrumentation, true power quality monitoring and real cost of service measurements. Whether you are metering the simplest energy rate or collecting critical quality of service and load analysis information on a polyphase or a single phase circuit, there is a kV2c meter configuration to meet your needs.

The Aclara kV2c meter family is one of the most widely accepted ANSI® commercial and industrial meters with over two million units deployed in the field since its introduction. The robust revenue-grade meter design is based on Aclara’s cutting edge technology that provides high accuracy and reliability.

Metrology
kWh, kVARh and kVAh energy measurements with associated demand values
ANSI C12.20 Accuracy Class 0.2% with typical accuracy better than 0.2% Programmable sag and swell monitor that logs voltage sag and swell duration down to one cycle
Time and date stamped meter event log
Robust revenue-grade watt-hour and demand meter with advanced recording options.

Versatile programming softswitches allowing the selection of advanced functionality such as expanded recording features, time of use, load profile and power quality measures.

Powerful functional upgrades provide 8-channel 64 kb, 20-channel 192 kB, or 20-channel 384 kB recording for voltage, current, real and reactive energy, apparent energy, distortion kVAh, THD and TDD.

Page 216 ends

ATTACHMENT 2
A2-217
©2019 Sensus. All products purchased and services performed are subject to Sensus’ terms of sale, available at either sensus.com/TC or 1-800-638-3748. Sensus reserves the right to modify these terms and conditions in its own discretion without notice to the customer. The Sensus logo is a registered trademark of Sensus.

This document is for informational purposes only, and SENSUS MAKES NO EXPRESS W ARRANTIES IN THIS DOCUMENT. FURTHERMORE, THERE ARE NO IMPLIED W ARRANTIES, INCLUDING

WITHOUT LIMITATION, W ARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY . ANY USE OF THE PRODUCTS THAT IS NOT SPECIFICALLY PERMITTED HEREIN IS PROHIBITED.
637 Davis Drive
Morrisville, NC 27560
1-800-638-3748
sensus.com
Specifications
Power Requirements Voltage Rating: 120 to 480 volts
Voltage Range: ±20% of voltage rating
Frequency: 50 or 60 Hz
Operating
Environment
Temperature: -40°C to +85°C (-40°F to
185°F)
Humidity: 0% to 95% non-condensing
Dimensions Diameter: 17.63 cm (6.94 inches)
Depth: 15.24 cm (6 inches)
Model FLEXKV2C
FCC ID SDBFLEXKV2C
ID 2220A-FLEXKV2C
Mechanical Design Durable one piece Lexan™ cover
Rugged single action reset lever
Magnetic switch activates alternates
Alternate and Site Genie displays
Accuracy Meets ANSI C12.20 for accuracy class 0.2
Typical accuracy better than ±0.2%
Tamper Detection
Options
Received kWh detection (optional)
Demand reset counter
FlexNet on-board vibration sensor
Load Profile Up to 20 channels of ANSI C12.19 load
profile data.

Up to 15 snapshots
Connect/Disconnect
Switch
Available on Form 16S, Class 100, 120 – 240,
50/60 Hz meter only
Three pole, single throw, magnetically-
latching
Endurance: 5000 cycles @ 100A, 240Vac,
50/60 Hz, 30,000 mechanical operations
Characteristic Data Starting current: Typically less than 0.1 amps for SC meters; 0.05 amps for TR meters
Typical Watts Loss: < 0.8W @ 120V, Phase A;
< 0.1W @ 120V, Phase B & C
LCD Display Six digit liquid crystal display
User-definable scroll list; 75 items total
Power flow and mechanical disk emulator
kWh display with segment check option
Aclara kV2c Electric Meter
Commercial & Industrial Meter with FlexNet® SmartPoint® Options
Service 1ɸ,
2 wire
1ɸ,
3 wire
1ɸ,
2 wire
1ɸ, 3
wire
3ɸ, 4 wire,
Wye or ∆
Network or
3ɸ, 3 wire ∆
3ɸ, 4 wire,
Wye or ∆
3ɸ, 4 wire,
Wye
Network or 3 ɸ,
3 wire ∆
Class 200 200 & 320 20 20 20 200 & 320 200 & 320 20 20
Form 1S 2S 3S 4S 9S 12S 16S 36S 45S
An optional form 16S, class 100, 120 volt meter with 3 ɸ RCDC switch is available.

Form 36S replaces form 6S; form 45S replaces form 5S and form 35S meters.

Form 9S and 16S meters support Aclara’s Fitzall™ feature.

Meter Functionality
Meter Features Bi-directional real and reactive energy and demands
Q-hour meter
Real time pricing (CPP)
TOU Meter
Up to 20 channel load profile recorder
Power quality meter (THD, TDD and distortion
power)
Current and Voltage recorder
Transformer/Line loss and accuracy
compensation
Real time multifunction instrument
Four quadrant meter
Individual phase metering
Logging Security Log
Voltage sag and swell log
Meter events log
Some functionality may require additional soft switches.

Page 217 ends

ATTACHMENT 2
A2-218
637 Davis Drive
Morrisville, NC 27560
1-800-638-3748

Sensus Limited Warranty G-500 R23

1. General Product Coverage. Unless otherwise provided herein, Sensus USA Inc. (“Sensus”) warrants its products and parts to be free from defects in material and workmanship for one (1) year from the date of Sensus shipment and as set forth below.

All products are sold to customer (“Customer”) pursuant to Sensus’ Terms of Sale, avail - able at: sensus.com/TC (“Terms of Sale”).

2. SR II® and accuSTREAM™ 5/8”, 3/4” & 1” Meters are warranted to perform to new meter accuracy level set forth in the SR II and accuSTREAM Data Sheets available at sensus.com for five (5) years from the date of Sensus shipment or until the registration shown below, whichever occurs first. Sensus further warrants that the SR II and accuSTREAM meters will perform to at least AWWA Repaired Meter Accuracy Standards for fifteen (15) years from the date of Sensus shipment or until the registration shown below, whichever occurs first:

New Meter Accuracy Repair Meter Accuracy
5/8” SR II Meter and
accuSTREAM Meter 500,000 gallons 1,500,000 gallons
3/4” SR II Meter and
accuSTREAM Meter 750,000 gallons 2,250,000 gallons
1” SR II Meter and
accuSTREAM Meter 1,000,000 gallons 3,000,000 gallons

3. ally® Meters that register water flow are warranted to perform to the accuracy level set forth in the ally Data Sheet available at sensus.com for fifteen (15) years from the Date of Installation, but no longer than sixteen (16) years from date of manufacture, not including the meter’s sensors, valve, and gear motor, which are warranted under different terms described below. As used herein, “Date of Installation” means the date after which the ally Meter has been out of empty pipe for seven (7) consecutive days, as those days are measured by the ally Meter and stored in the meter’s nonvolatile memory.

4. iPERL® Meters that register water flow are warranted to perform to the accuracy levels set forth in the iPERL Data Sheet available at sensus.com for twenty (20) years from the date of Sensus shipment. The iPERL System Component warranty does not include the external housing.

5. SR II maincases are warranted to be free from defects in material and work manship for twenty-five (25) years from the date of Sensus shipment. accuSTREAM maincases will be free from defects in material and workmanship for fifteen (15) years from the date of Sensus shipment.

6. Sensus OMNI ™ Meters and Propeller Meters are warranted to perform to as set forth in OMNI and Propeller data sheets for one (1) year from the date of Sensus shipment.

7. Sensus accuMAG™ and HydroverseTM Meters are warranted to be free from defects in material and workmanship, under normal use and service, for 18 months from the date of Sensus shipment or 12 months from startup, whichever occurs first.

8. Sensus Registers are warranted to be free from defects in material and workmanship from the date of Sensus shipment for the periods stated below or until the applicable registration for AWWA Repair ed Meter Accuracy Standards, as set forth above, are surpassed, whichever occurs first:
5/8” thru 1” SR II, accuSTREAM Standard Registers 25 years 5/8” thru 1” SR II, accuSTREAM Encoder Registers 10 years All HSPU, IMP Contactor, R.E.R. Elec. ROFI 1 year
Standard and Encoder Registers for Propeller Meters 1 year OMNI and OMNI+ Registers with Battery 10 years

9. Sensus Electric and Gas Meters are warranted pursuant to the General Limited Warranty available at sensus.com/TC.

10. Batteries, iPERL System Components, AMR and FlexNet ® Communication Network AMI Interface Devices are warranted to be free from defects in material and workmanship from the date of Sensus shipment for the period stated below:

Electronic TouchPad 10 years
Act-Pak® Remote Monitoring Instruments 1 year
Gas SmartPoint® Modules and Batteries 20 years1
6500 series Hand-Held Device 2 years
Vehicle Gateway Base Station (VGB) and other AMR Equipment 1 year EasyLink Reader 1 Year
CPTP100 20 Years2
FlexNet Base Station (including the R100NA and M400 products) 1 year RM4160 1 Year
iPERL System Battery and iPERL System Components 20 years3

1 Sensus will repair or replace non-performing Gas SmartPoint Modules (configured to the factory setting of six transmissions per day under normal system operation of up to one demand read to each SmartPoint Module per month and up to five firmware downloads during the life of the product) and batteries.
2 Sensus will repair or replace non-performing CPTP100 modules (configured at factory setting of four transmissions per day under normal system operations of up to one demand read per month and up to five firmware downloads during the life of the product) and batteries.

Sensus® Electronic Register+™ 20 years4
Sensus® Smart Gateway Sensor Interface 1 year5
SmartPoint® 510M/520M/515M/512M Modules and Batteries 20 years3

11. ally® Meter Batteries and Components, including SmartPoint 510M/520M Modules are warranted to be free from defects in material and workmanship from the Date of Installation, as defined in Section 3, for the period stated below:

Batteries 15 years6
Sensors 5 years
Valve & Gear Motor 5 years7
SmartPoint 510M/520M Modules and Batteries in service w/ally 15 years6

3 Sensus will repair or replace non-performing:
• iPERL System Batteries, and/or the iPERL System flowtube, the flow sensing and data processing assemblies, and the register (“iPERL System Components”) with hourly reads, • SmartPoint 510M/520M/515M//512M -PLS Modules (configured to the factory setting of six transmissions per day under normal system operation of up to one demand read to each SmartPoint Module per month and up to five firmware downloads during the life of the product) and batteries, unless the SmartPoint 510M/520M Module is ever paired with an ally Meter, which event immediately amends the warranty terms to those described in Section 11; at no cost for the first fifteen (15) years from the date of Sensus shipment, and for the remaining five (5) years at a prorated percentage, applied towards the published list price in effect for the year the product is accepted by Sensus under the warranty conditions according to the following schedule:

Years Replacement Price
1 – 15 0%
16 30%
17 40%
18 50%
19 60%
20 70%
>20 100%

4 Sensus will repair or replace non-performing Sensus Electronic Register+ with hourly reads for the first ten (10) years from the date of Sensus shipment, and for the remaining ten (10) years, at a prorated percentage, applied towards the published list prices in effect for the year product is accepted by Sensus under warranty conditions according to the following schedule:

Years Replacement Price Years Replacement Price
1 – 10 0% 16 55%
11 30% 17 60%
12 35% 18 65%
13 40% 19 70%
14 45% 20 75%
15 50% >20 100%

5 Sensus® Smart Gateway Sensor Interface warranty valid only for analog Meter Sample Rates of four times per hour with a Standard Tranmsit Rate of hourly or greater for the analog channel(s). 6 If applicable, any SmartPoint 510M/520M Modules ever paired with an ally Meter are warranted with the following limitations:
• When configured to the default installation setting of six transmissions of metrology and pressure per day and one update of temperature per day, the SmartPoint is warranted to perform up to five (5) firmware upgrades for the SmartPoint Module and up to five (5) firmware upgrades for the ally Meter; • 2500 Operational Commands, where “Operational Commands” include on demand reads (such as consumption, pressure, temperature), an ally valve command, or a configuration command; and • 15 Diagnostic Commands, which includes two-way communications tests and installations for the first ten (10) years from Date of Installation at no cost. For the remaining five (5) years, Customer will pay the reduced Replacement Price of the then- current list price in effect at the time the product is accepted for return in accordance with the following schedule:

Years Replacement Price Years Replacement Price
1 – 10 0% 14 65%
11 35% 15 75%
12 45% >15 100%
13 55%

7 Notwithstanding the foregoing, valve and gear motor components of ally Meters are not warranted beyond two thousand (2000) Valve State Operations, even if the warranty period provided herein has not yet expired. As used herein, “Valve State Operations” means adjustments of the Meter to open, close, or reduce flow.

Page 218 ends

ATTACHMENT 2
A2-219
637 Davis Drive
Morrisville, NC 27560
1-800-638-3748

12. iPERL and ally Connectors and Cables are warranted to be free from defects in materials and workmanship, under normal use and service, for ten (10) years from the date of Sensus shipment. Nicor or Itron connectors included with a Sensus product are warranted according to the terms for Third-Party Devices in Section 13.

13. Third-Party Devices are warranted to be free from defects in materials and workmanship, under normal use and service, for one (1) year from the date of Sensus shipment. As used in this Sensus Limited Warranty, “Third Party Devices” means any product, device, or component part used with a Sensus product that is manufactured or sold by any party that is not Sensus. Failure of a Third Party Device which subsequently causes failure to a Sensus device shall be the responsibility of the manufacturer of the Third Party Device.

14. Software. Software supplied and/or licensed by Sensus is supported according to the terms of the applicable software license or usage agreement. Sensus warrants that any network and monitoring services shall be performed in a professional and workmanlike manner.

15. Return. Sensus’ obligation, and Customer’s exclusive remedy, under this Sensus Limited Warranty is, at Sensus’ option, to either (i) repair or replace the product, provided the Customer (a) returns the product to the location designated by Sensus within the warranty period; and (b) prepays the freight costs both to and from such location; or (ii) deliver replacement components to the Customer, provided the C ustomer installs, at its cost, such components in or on the product (as instructed by Sensus), provided, that if Sensus requests, the Customer (a) returns the product to the location designated by Sensus within the warranty period; and (b) prepays the frei ght costs both to and from such location. In all cases, if Customer does not return the product within the time period designated by Sensus, Sensus will invoice, and Customer will pay within thirty days of the invoice date, for the cost of the replacement product and/or components.

The return of products for warranty claims must follow Sensus’ Returned Materials Authorization (RMA) procedures. Water meter returns must include documentation of the Customer’s test results. Test results must be obtained according to AWWA standards and must specify the meter serial number. The test results will not be valid if the meter is found to contain foreign materials. If Customer chooses not to test a Sensus water meter prior to returning it to Sensus, Sensus will repair or replace the meter, at Sensus’ option, after the meter has been tested by Sensus. The Customer will be charged Sensus’ then current testing fee. All product must be returned in accordance with the RMA process. For all returns, Sensus reserves the right to request meter read- ing records by serial number to validate warranty claims.

For products that have become discontinued or obsolete (“Obsolete Product ”), Sensus may, at its discretion, replace such Obsolete Product with a different product model (“New Product”), provided that the New Product has substantially similar features as the Obsolete Product. The New Product shall be warranted as set forth in this Sensus Limited Warranty.

THIS SECTION 15 SETS FORTH CUSTOMER’S SOLE REMEDY FOR THE FAILURE

OF THE PRODUCTS, SERVICES OR LICENSED SOFTWARE TO CONFORM TO THEIR RESPECTIVE WARRANTIES.

16. Warranty Exceptions and No Implied Warranties. This Sensus Limited Warranty does not include costs for removal or installation of products, or costs for replacement labor or materials, which are the responsibility of the Customer. The warranties in this Sensus Limited Warranty do not apply to and Sensus has no liability for goods that have been: installed improperly or in non-recommended installations; installed to a socket that is not functional, or is not in safe operating condition, or is damaged, or is in need of repair; tampered with; modified or repaired with parts or assemblies not certified in writing by Sensus, including without limitation, communication parts and assemblies; improperly modified or repaired (including as a result of modifications required by Sensus); converted; altered; damaged; read by equipment not approved by Sensus; for water meters, used with substances other than water, used with no n-potable water, or used with water that contains dirt, debris, deposits, or other impurities; subjected to misuse, improper storage, improper care, improper maintenance, or improper periodic testing (collectively, “Exceptions.”). If Sensus identifies any Exceptions during examination, troubleshooting or performing any type of support on behalf of Customer, then Customer shall pay for and/or reimburse Sensus for all expenses incurred by Sensus in examining, troubleshooting, performing support activities, repairing or replacing any Equipment that satisfies any of the Exceptions defined above. The above warranties do not apply in the event of Force Majeure, as defined in the Terms of Sale.

THE WARRANTIES SET FORTH IN THIS SENSUS LIMITED WARRANTY ARE THE

ONLY WARRANTIES GIVEN WITH RESPECT TO THE GOODS, SOFTWARE,

SOFTWARE LICENSES AND SERVICES SOLD OR OTHERWISE PROVIDED BY SENSUS. SENSUS EXPRESSLY DISCLAIMS ANY AND ALL OTHER

REPRESENTATIONS, WARRANTIES, CONDITIONS, EXPRESSED, IMPLIED,

STATUTORY OR OTHERWISE, REGARDING ANY MATTER IN CONNECTION WITH

THIS SENSUS LIMITED WARRANTY OR WITH THE TERMS OF SALE, INCLUDING

WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, NON-INFRINGEMENT AND TITLE.

SENSUS ASSUMES NO LIABILITY FOR COS TS OR EXPENSES ASSOCIATED

WITH LOST REVENUE OR WITH THE REMOVAL OR INSTALLATION OF EQUIPMENT. THE FOREGOING REMEDIES ARE CUSTOMER’S SOLE AND

EXCLUSIVE REMEDIES FOR THE FAILURE OF EQUIPMENT, LICENSED

SOFTWARE OR SOFTWARE SERVICES, AND OTHER SERVICES TO CONFORM TO THEIR RESPECTIVE WARRANTIES.

17. Limitation of Liability . SENSUS’ AGGREGATE LIABILITY IN ANY AND ALL

CAUSES OF ACTION ARISING UNDER, OUT OF OR IN RELATION TO THIS

AGREEMENT, ITS NEGOTIATION, PERFORMANCE, BREACH OR TERMINATION (COLLECTIVELY “CAUSES OF ACTION”) SHALL NOT EXCEED THE TOTAL AMOUNT PAID BY CUSTOMER TO SENSUS UNDER THIS AGREEMENT. THIS IS SO WHETHER

THE CAUSES OF ACTION ARE IN TORT, INCLUDING, WITHOUT LIMITATION,

NEGLIGENCE OR STRICT LIABILITY, IN CONTRACT, UNDER STATUTE OR OTHERWISE.

AS A SEPARATE AND INDEPENDENT LIMITATION ON LIABILITY, SENSUS’ L IABILITY SHALL BE LIMITED TO DIRECT DAMAGES. SENSUS SHALL NOT BE LIABLE FOR: (I) ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES; NOR (II)

ANY REVENUE OR PROFITS LOST BY CUSTOMER OR ITS AFFILIATES FROM ANY

END USER(S), IRRESPECTIVE OF WHETHER SUCH LOST REVENUE OR PROFITS IS CATEGORIZED AS DIRECT DAMAGES OR OTHERWISE; NOR (III) ANY IN/OUT COSTS; NOR (IV) MANUAL METER READ COSTS AND EXPENSES; NOR (V)

DAMAGES ARISING FROM MAINCASE OR BOTTOM PLATE BREAKAGE CAUSED BY

FREEZING TERMPERATURES, WATER HAMMER CONDITIONS, OR EXCESSIVE WATER PRESSURE. “IN/OUT COSTS” MEANS ANY COSTS AND EXPENSES

INCURRED BY CUSTOMER IN TRANSPORTING GOODS BETWEEN ITS WAREHOUSE AND ITS END USER’S PREMISES AND ANY COSTS AND EXPENSES INCURRED BY CUSTOMER IN INSTALLING, UNINSTALLING AND REMOVING GOODS. “END USER”

MEANS ANY END USER OF ELECTRICITY/WATER/GAS THAT PAYS CUSTOMER FOR THE CONSUMPTION OF ELECTRICITY/WATER/GAS, AS APPLICABLE.

The limitations on liability set forth in this Agreement are fundamental inducements to Sensus entering into this Agreement. They apply unconditionally and in all respects. They are to be interpreted broadly so as to give Sensus the maximum protection permitted under law.

Page 219 ends

ATTACHMENT 2
A2-220
8601 Six Forks Road, Suite 700
Raleigh, NC 27615
1-800-638-3748
General Limited Warranty

1. Terms of Sale. Sensus USA Inc. (“Sensus”) warrants its products and parts as set forth below. All products are sold to the buyer (“Customer”) pursuant to Sensus’ Terms of Sale, available at: http://sensus.com/TC/ (“Terms of Sale”).

2. Electricity Meters and Electricity SmartPoint™ Modules. Sensus warrants the Sensus electricity meters and Sensus electricity SmartPoint Modules to be in compliance with their respective specifi cations under normal use and service, and to be free from material defects in materials and workmanship for a warranty period of twelve (12) months from the date of the installation or eighteen (18) months from the date of shipment, whichever occurs fi rst. The warranty period for new spare parts and components sold by Sensus is twelve (12) months from the date of shipment. The warranty period for repaired or refurbished parts repaired by Sensus is ninety (90) days from the date of shipment, unless repaired pursuant to a warranty, in which case the repair is warranted for the time remaining of the original warranty period.

3. Gas Products and Gas SmartPoint Modules.
a. Except for the Sonix meters, Sensus warrants the Sensus gas products to be in compliance with their respective specifi cations under normal use and service, and to be free from material defects in materials and workmanship for a warranty period of twelve (12) months from the date of the installation or eighteen (18) months from the date of shipment, whichever occurs fi rst. Sensus warrants the Sensus Sonix meters to be free from material defects in materials and workmanship for a warranty period of fi fteen (15) years from the date of shipment. Sensus warrants the batteries in the Sensus Sonix meters to be free from material defects in materials and workmanship for a warranty period of ten (10) years from the date of shipment. The warranty period for new spare parts and components sold by Sensus is twelve (12) months from the date of shipment.

The warranty period for repaired or refurbished parts repaired by Sensus is ninety (90) days from the date of shipment, unless repaired pursuant to a warranty, in which case the repair is warranted for the time remaining of the original warranty period.
b. Sensus warrants the Sensus gas SmartPoint Modules as set forth in the “G500” warranty, as set forth at:
http://sensus.com/TC/, or available at 1-800-METER-IT.

4. Water Meters and Water SmartPoint Modules. Sensus warrants the Sensus water meters and Sensus water SmartPoint Modules as set forth in the “G500” warranty, as set forth at: http://sensus.com/TC/, or available at 1-800-METER-IT.

5. DA Devices and HAN Devices. Sensus warrants the Sensus DA Devices and Sensus HAN Devices to be in compliance with their respective speci fi cations under normal use and service, and to be free from material defects in materials and workmanship for a warranty period of twelve (12) months from the date of shipment.

The warranty period for new spare parts and components sold by Sensus is twelve (12) months from the date of shipment. The warranty period for repaired or refurbished parts repaired by Sensus is ninety (90) days from the date of shipment, unless repaired pursuant to a warranty, in which case the repair is warranted for the time remaining of the original warranty period.

6. RF Field Equipment. Sensus warrants the Sensus RF Field Equipment to be in compliance with their respective specifi cations under normal use and service, and to be free from material defects in materials and workmanship for a warranty period of twelve (12) months from the date of shipment.

7. Server Hardware. Sensus provides no warranty on the Server Hardware.

8. Third Party Goods. Notwithstanding anything to the contrary herein, Sensus does not warrant any goods manufactured or software supplied by third parties. For example, if Customer elects to buy meters from a third party, the Sensus SmartPoint Modules installed in such third party meters shall, subject to Section 11, below, be covered by the warranty above, but any warranty on the meter itself shall be a matter directly between Customer and such third party meter supplier.

9. Services. Sensus warrants that its services shall, at the time of performance, materially conform to the contract requirements, and shall be performed in a professional and workmanlike manner, free from material defects in workmanship.

10. Remedy.
a. If any Field Device or RF Field Equipment fails during the applicable warranty period (a “Failed Good”), Sensus’ obligation, and Customer’s exclusive remedy, is, at Sensus’ option, to either (i) repair or replace the Failed Good, provided the Customer (a) returns the product to the location designated by Sensus within the warranty period; and (b) prepays the freight costs both to and from such location; or (ii) deliver replacement components to the Customer, provided the Customer installs, at its cost, such components in or on the Failed Good (as instructed by Sensus). In all cases, Customer shall be responsible for returning the Failed Good to Sensus, including all costs associated with the return of the Failed Good, and Sensus shall be responsible for shipping the repaired or replaced good back to Customer’s warehouse. Customer shall, in all cases, be responsible for the In/Out Costs. If Sensus determines that the returned good is not defective, Customer shall pay and/or reimburse Sensus for all expenses incurred by Sensus in the examination of the returned good.
b. Customer’s remedy under the warranty for services shall be, at Sensus’ sole cost and expense, to correct or re-perform any defective or non-conforming services to assure compliance with the contract requirements. c. THIS SECTION 10 SETS FORTH CUSTOMER’S SOLE REMEDY WITH RESPECT TO A FAILED GOOD OR ANY DEFECTIVE OR NON-CONFORMING SERVICE.

11. Warranty Exceptions. This General Limited Warranty does not include costs for removal or instal¬lation of products, or costs for replacement labor or materials, which are the responsibility of the Customer. The warranties in this General Limited Warranty do not apply to goods that have been: installed improperly or in non-recommended installations; installed to a socket that is not functional, or is not in safe operating condition, or is damaged, or is in need of repair; tampered with; modifi ed or repaired with parts or assemblies not certifi ed in writing by Sensus, including without limitation, communication parts and assemblies; improperly modi fi ed or repaired (including as a result of modi fi cations required by Sensus); converted; altered; damaged; read by equipment not approved by Sensus; for water meters, used with substances other than water, used with non- potable water, or used with water that contains dirt, debris, deposits, or other impurities; subjected to misuse, improper storage, improper care, improper maintenance, or improper periodic testing (collectively, “Exceptions.”).

If Sensus identi fi es any Exceptions during examination, troubleshooting or performing any type of support on behalf of Customer, then Customer shall pay for and/or reimburse Sensus for all expenses incurred by Sensus in examining, troubleshooting, performing support activities, repairing or replacing any Equipment that satisfi es any of the Exceptions defi ned above. The above warranties do not apply in the event of Force Majeure, as defi ned in the Terms of Sale.

12. THE WARRANTIES SET FORTH IN THIS GENERAL LIMITED WARRANTY ARE THE ONLY WARRANTIES

GIVEN WITH RESPECT TO THE GOODS, SOFTWARE LICENSES AND SERVICES SOLD OR OTHERWISE PROVIDED BY SENSUS. SENSUS EXPRESSLY DISCLAIMS ANY AND ALL OTHER REPRESENTATIONS

AND WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, NON-INFRINGEMENT AND TITLE.

13. SENSUS ASSUMES NO LIABILITY FOR COSTS OR EXPENSES ASSOCIATED WITH LOST REVENUE OR WITH THE REMOVAL OR INSTALLATION OF EQUIPMENT. THE FOREGOING REMEDIES ARE CUSTOMER’S SOLE AND EXCLUSIVE REMEDIES FOR THE FAILURE OF EQUIPMENT, LICENSED SOFTWARE OR SERVICES TO CONFORM TO THEIR RESPECTIVE WARRANTIES.

12. THE WARRANTIES SET FORTH IN THIS GENERAL LIMITED WARRANTY ARE THE ONLY WARRANTIES

GIVEN WITH RESPECT TO THE GOODS, SOFTWARE LICENSES AND SERVICES SOLD OR OTHERWISE PROVIDED BY SENSUS. SENSUS EXPRESSLY DISCLAIMS ANY AND ALL OTHER REPRESENTATIONS

AND WARRANTIES, INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, NON-INFRINGEMENT AND TITLE.

13. SENSUS ASSUMES NO LIABILITY FOR COSTS OR EXPENSES ASSOCIATED WITH LOST REVENUE OR WITH THE REMOVAL OR INSTALLATION OF EQUIPMENT. THE FOREGOING REMEDIES ARE CUSTOMER’S SOLE AND EXCLUSIVE REMEDIES FOR THE FAILURE OF EQUIPMENT, LICENSED SOFTWARE OR SERVICES TO CONFORM TO THEIR RESPECTIVE WARRANTIES.

14. Limitation of Liability
a. SENSUS’ AGGREGATE LIABILITY IN ANY AND ALL CAUSES OF ACTION ARISING UNDER, OUT OF OR

IN RELATION TO THIS AGREEMENT, ITS NEGOTIATION, PERFORMANCE, BREACH OR TERMINATION (COLLECTIVELY “CAUSES OF ACTION”) SHALL NOT EXCEED THE TOTAL AMOUNT PAID BY CUSTOMER TO SENSUS UNDER THIS AGREEMENT. THIS IS SO WHETHER THE CAUSES OF ACTION

ARE IN TORT, INCLUDING, WITHOUT LIMITATION, NEGLIGENCE OR STRICT LIABILITY, IN CONTRACT, UNDER STATUTE OR OTHERWISE.
b. AS A SEPARATE AND INDEPENDENT LIMITATION ON LIABILITY, SENSUS’ LIABILITY SHALL BE LIMITED TO DIRECT DAMAGES. SENSUS SHALL NOT BE LIABLE FOR: (I) ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES; NOR (II) ANY REVENUE OR PROFITS LOST

BY CUSTOMER OR ITS AFFILIATES FROM ANY END USER(S), IRRESPECTIVE OF WHETHER SUCH LOST REVENUE OR PROFITS IS CATEGORIZED AS DIRECT DAMAGES OR OTHERWISE; NOR (III) ANY IN/OUT COSTS; NOR (IV) MANUAL METER READ COSTS AND EXPENSES. c. The limitations on liability set forth in this Agreement are fundamental inducements to Sensus entering into this Agreement. They apply unconditionally and in all respects. They are to be interpreted broadly so as to give Sensus the maximum protection permitted under law. d. To the maximum extent permitted by law, no Cause of Action may be instituted by Customer against Sensus more than TWELVE (12) MONTHS after the Cause of Action fi rst arose. In the calculation of any damages in any Cause of Action, no damages incurred more than TWELVE (12) MONTHS prior to the fi ling of the Cause of Action shall be recoverable.

15. Defi nitions. Any terms used in this General Limited Warranty as defi ned terms, and which are not defi ned herein, shall have the meanings given to those terms in the Terms of Sale. a. “Agreement” means this General Limited Warranty, Customer’s purchase order (except any Additional Terms), Sensus’ Acknowledgement Form (if any), Sensus’ invoice and the Terms of Sale. b. “DA Devices” means RTMs and RTUs.
c. “Echo Transceiver” (formerly “FlexNet Network Portal” and “FNP”) identifi es the Sensus standalone, mounted relay device that takes the radio frequency readings from the SmartPoint Modules and relays them by radio frequency to the relevant FlexNet Base Station.
d. “End User” means any end user of electricity/water/gas that pays Customer for the consumption of electricity/ water/gas, as applicable.
e. “Equipment” means the Field Devices, RF Field Equipment, Server Hardware, and any other goods sold hereunder.
f. “FlexNet Base Station” (formerly “Tower Gateway Base Station” and “TGB”) identi fi es the Sensus manufactured device consisting of one transceiver, to be located on a tower that receives readings from the SmartPoint Modules (either directly or via an Echo Transceiver) by radio frequency and passes those readings to the RNI by TCP/IP backhaul communication.
g. “Field Devices” means the meters, SmartPoint Modules, DA Devices and HAN Devices. h. “Force Majeure” shall have the meaning set forth in the Terms of Sale. i. “HAN Devices” means the PCTs, IHDs and LCMs.
j. “IHDs” means the in-home displays.
k. “In/Out Costs” means any costs and expenses incurred by Customer in transporting goods between its warehouse and its End User’s premises and any costs and expenses incurred by Customer in installing, uninstalling and removing goods.
l. “LCMs” means the load control modules.
m. “PCTs” means the programmable controllable thermostats. n. “Remote Transceiver” (formerly “FlexNet Remote Portal” and “FRP”) identi fi es the Sensus standalone, mounted relay device that takes the radio frequency readings from the SmartPoint Modules and relays them directly to the RNI by TCP/IP backhaul communication.
o. “RNI” identifi es the regional network interfaces consisting of hardware and software used to gather, store, and report data collected by the FlexNet Base Stations from the SmartPoint Modules. p. “RF Field Equipment” means, collectively, FlexNet Base Stations, Echo Transceivers and Remote Transceivers.
q. “RTMs” means the telemetric remote telemetry modules. r. “RTUs” means telemetric MicroRTU (T866).
s. “Server Hardware” means the RNI hardware and the FlexServer hardware. t. “SmartPoint™ Modules” identi fi es the Sensus transmission devices installed on devices such as meters, distribution automation equipment and demand/response devices located at Customer’s End Users’ premises that take the readings of the meters and transmit those readings by radio frequency to the relevant FlexNet Base Station, Remote Transceiver or Echo Transceiver.

CF-C-WAR-00-00-0613-07-A

Page 220 ends

ATTACHMENT 2
A2-221
Sensus AMI System Performance Warranty

1. Terms of Sale
Sensus USA Inc. (“Sensus”) warrants the performance of the AMI System to the Customer as set forth below. This warranty and all products and services sold or otherwise provided by Sensus directly to the Customer are pursuant to the Sensus Terms of Sale, available at:
http://na.sensus.com/TC/TermsConditions.pdf (“Terms of Sale”).

2. Performance Warranty. The “Performance Warranty” is as follows:

A. Warranty. Sensus warrants to Customer that the AMI System deployed for a particular Utility Customer meets the performance test standards set forth below in section 3 (“Performance Test Standards”) from the Effective Date until the Warranty End Date.

If the Utility Customer’s AMI System does not meet such Performance Test Standards, then as Sensus’ sole obligation and Customer’s sole remedy, Sensus shall take steps that Sensus deems necessary, in Sensus’ sole discretion, to cause the AMI System to satisfy the Performance Test Standards. Such steps may include Sensus’ delivery to the Utility Customer (without charge to the Utility Customer) the hardware for additional RF Field Equipment, provided that all RF Field Equipment shall be located and installed as directed by Sensus. Utility Customer shall have title to all equipment provided pursuant to this subsection (A). Notwithstanding anything to the contrary, Customer shall pay for any Recurrent RF Field Equipment Fees and any Ongoing Fees for all equipment provided pursuant to this subsection (A).

B. Limitations. The Performance Warranty shall only apply; (i) to the Meter Data; (ii) from the Effective Date until the Warranty End Date; (iii) if Sensus has completed a propagation study for the applicable Utility Customer based on the Performance Test Standards, such propagation study has been approved in writing (including without limitation, by email) by Sensus, and such propagation study has been agreed to in writing (including without limitation, by email) by the Utility Customer (“ Certified Propagation Study”) (for clarity, the Certified Propagation Study consists of all documents of the propagation study, including without limitation, the server map and the document describing the Required RF Field Equipment locations and antennae details); (iv) if the Utility Customer has entered into a Spectrum Lease Agreement with Sensus; (v) if all the Required RF Field Equipment identified in the Certified Propagation Study is installed; (vi) if the Required RF Field Equipment is installed as described in the Certified Propagation Study, including without limitation, in the locations and at the heights identified in the Certified Propagation Study; and (vii) the Required RF Field Equipment is operating and has been maintained to Sensus’ specifications (collectively, the “Requirements”). If any Requirement is not satisfied, then: the Performance Warranty is void; Sensus has no obligation to remedy the AMI System performance; Sensus has no obligation to provide RF Field Equipment hardware at no cost; and Customer is responsible for purchasing such RF Field Equipment, even if it is necessary to meet the specifications set forth in the Performance Test Standards.

Furthermore, if new and/or different RF Field Equipment locations are required as a result of not meeting any Requirements, Customer agrees to: pay Sensus for the completion of any additional propagation studies; pay Sensus for the additional RF Field Equipment hardware; perform the necessary site preparation; and pay for any Recurrent RF Field Equipment Fees and any Ongoing Fees for all equipment purchased pursuant to this subsection (B). Any equipment required pursuant to this subsection (B) is added to the definition of “Required RF Field Equipment.”

3. Performance Test Standards
A. Generally.
i. The parties shall mutually agree on specific reading routes (each a “ Route”).

Each Route will be separately tested with the intent to provide incremental acceptance of distinctly defined geographical areas and populations of meters.

Each Route shall contain a statistical sample of Test Units (“Route Units”). Route Units only include the Test Units installed in the applicable Route. For Utility Customers with any combination of water, gas, and electricity Endpoints, the water Endpoints, gas Endpoints, and electricity Endpoints will each be tested separately according to the procedure below. For clarity, a single Route will not have a combination of water, gas, and electricity meters, but it will consist of only water, gas, or electricity Test Units.
ii. Before beginning the Performance T est Standards, all Route Units must be installed. Customer shall send written notice to Sensus once the Test Equipment and all Route Units are installed (“Route Deployment”). Such notice shall indicate the date on which the Route Deployment was completed (“ Route Deployment Date”).
iii. Within thirty (30) days after the Route Deployment Date, the parties shall begin the Performance Test Standards on the Route. Customer, Utility Customer, and Sensus shall work in good faith to complete the Performance Test Standards no later than thirty (30) days after commencement of testing.

B. Route Read Success Test.
i. The Route Read Success Test will measure the percentage of Route Units that deliver valid billable meter reads during the Billing Window. The Route Read Success Test only measures reads sent from the Route Units; it does not include on demand reads. The commencement date of the Billing Window shall be agreed by Customer and Sensus.

Route Read Success = 100 x
(# of Route Units that deliver a valid billable meter
read during the Billing Window)
(total # of Route Units in the applicable Route)
ii. If Route Read Success is equal or greater than the Success Percentage during one Billing Window, the Performance Test Standards for that Route has passed. Customer shall promptly issue written notice to Sensus that either (a) Sensus has not successfully completed the Performance Test Standards for the applicable Route; or (b) Sensus has successfully completed the Performance Test Standards for the applicable Route and such notice shall specify the applicable Route and shall state the date on which the Route Read Success Test was successfully completed. If Customer does not issue such notice within five days of completion of the test, then the test is automatically deemed successfully passed. Sensus has no obligation to continue optimizing the system and meeting performance specifications upon successful completion of the Performance Test Standards for each Route. This process shall continue until all Routes have successfully completed the Performance Test Standards.

If Sensus does not successfully complete the Performance Test Standards for the applicable Route, then upon receipt of notice, Sensus shall fulfill its obligations in Section 2 above, and the applicable Route shall be retested within a reasonable time.
iii. Upon completion of the Performance T est Standards for all Routes, Customer shall promptly issue written notice to Sensus that either (a) Sensus has not successfully completed the Performance Test Standards for the AMI System; or (b) Sensus has successfully completed the Performance Test Standards for the AMI System and such notice shall state the date on which the Performance Test Standards was successfully completed. If Customer does not issue such notice within five days of completion of the tests, then the Performance Test Standards for the AMI System is automatically deemed successfully passed. If Sensus does not successfully complete the Performance Test Standards, then upon receipt of notice, Sensus shall fulfill its obligations in Section 2 above, and the AMI System shall be retested within a reasonable time.

4. THE WARRANTY SET FORTH IN SECTION 2 OF THIS PERFORMANCE WARRANTY IS THE ONLY WARRANTY RELATED TO THE PERFORMANCE OF THE AMI SYSTEM.

SENSUS EXPRESSLY DISCLAIMS ANY AND ALL OTHER REPRESENTATIONS,

WARRANTIES, CONDITIONS, EXPRESSED, IMPLIED, STATUTORY OR OTHERWISE,

REGARDING ANY MATTER IN CONNECTION WITH THESE TERMS OF SALE,

INCLUDING WITHOUT LIMITATION, WARRANTIES AS TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, NON-INFRINGEMENT AND TITLE.

5. SENSUS ASSUMES NO LIABILITY FOR COSTS OR EXPENSES ASSOCIATED WITH LOST REVENUE OR WITH THE REMOVAL OR INSTALLATION OF EQUIPMENT. THE FOREGOING REMEDIES ARE CUSTOMER’S SOLE AND EXCLUSIVE REMEDIES FOR THE PERFORMANCE OF THE AMI SYSTEM.

6. Limitation of Liability.

SENSUS’ AGGREGA TE LIABILITY IN ANY AND ALL CAUSES OF ACTION ARISING

UNDER, OUT OF OR IN RELATION TO THIS WARRANTY AND ALL OTHER AGREEMENTS

BETWEEN SENSUS AND CUSTOMER, THEIR NEGOTIATION, PERFORMANCE, BREACH OR TERMINATION (COLLECTIVELY “CAUSES OF ACTION”) SHALL NOT EXCEED (I) IF CUSTOMER IS ALSO THE UTILITY CUSTOMER, THE TOTAL AMOUNT PAID BY CUSTOMER TO SENSUS; OR (II) IF CUSTOMER IS NOT THE UTILITY CUSTOMER,

THE TOTAL AMOUNT PAID BY CUSTOMER TO SENSUS SOLELY IN RELATION TO THE UTILITY CUSTOMER. THIS IS SO WHETHER THE CAUSES OF ACTION ARE IN

TORT, INCLUDING WITHOUT LIMITATION, NEGLIGENCE OR STRICT LIABILITY, IN CONTRACT, UNDER STATUTE OR OTHERWISE. AS A SEPARATE AND INDEPENDENT LIMITATION ON LIABILITY, SENSUS’ LIABILITY SHALL BE LIMITED TO DIRECT DAMAGES. SENSUS SHALL NOT BE LIABLE FOR: (I) ANY INDIRECT, INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES; NOR (II) ANY REVENUE OR PROFITS LOST

BY CUSTOMER, UTILITY CUSTOMER OR EITHER OF THEIR AFFILIATES FROM ANY

END USER(S), IRRESPECTIVE OF WHETHER SUCH LOST REVENUE OR PROFITS IS CATEGORIZED AS DIRECT DAMAGES OR OTHERWISE; NOR (III) ANY IN/OUT COSTS; NOR (IV) MANUAL METER READ COSTS AND EXPENSES. The limitations on liability set forth herein are fundamental inducements to Sensus. They apply unconditionally and in all respects. They are to be interpreted broadly so as to give Sensus the maximum protection permitted under law. To the maximum extent permitted by law, no Cause of Action may be instituted against Sensus more than TWELVE (12) MONTHS after the Cause of Action first arose. In the calculation of any damages in any Cause of Action, no damages incurred more than TWELVE (12) MONTHS prior to the filing of the Cause of Action shall be recoverable.

CF-C-WAR-00-01-0814-01-A

Page 221 ends

ATTACHMENT 2
A2-222

7. Definitions.

Any terms used in this Performance Warranty as defined terms, and which are not defined herein, shall have the meanings given to those terms in the Terms of Sale, as defined above.

A. “AMI System” identifies the Sensus FlexNet Advanced Meter Infrastructure System deployed by the Customer, comprised of the SmartPoint Modules, RF Field Equipment, regional network interface (RNI), software, FCC licenses, and other Sensus equipment provided to Customer and/or to the Utility Customer. The AMI System only includes the foregoing, as provided by Sensus to the Utility Customer, either directly or through a Sensus authorized distributor. The AMI System does not include goods, equipment, software, licenses or rights provided by a third party(ies).

B. “Available Meter” means an installed Sensus FlexNet meter (with a SmartPoint Module installed) or a Sensus SmartPoint Module which has been installed on a third party meter, and which, in either case, is not an Unavailable Meter (or on an Unavailable Meter in the case of SmartPoint Modules on third party meters) and which satisfies all of the following criteria: (i) it functions properly, is powered, and is not a damaged or failed meter; (ii) if applicable, it is in a deployment area of meters such that a sufficient number of two-way meters are in range of each other; (iii) it is serviced by RF Field Equipment that has not been subjected to a power failure greater than eight (8) total hours; (iv) neither it nor the RF Field Equipment that serves that meter has been affected by a Force Majeure event; (v) jamming of the radio spectrum is not preventing or interfering with radio communication to or from the meter; (vi) it is installed in the Service Territory; (vii) it has not been reported to Utility Customer under Sensus’ or Utility Customer’s preventative maintenance; (viii) its functioning or performance has not been adversely affected by a failure of Customer and/ or Utility Customer to perform its obligations or tasks for which it is responsible, including without limitation, testing and confirming that the socket to which the meter will be/is connected is in safe operating condition, is fully functional, is not corroded, does not contain improperly installed jaws or other deficiencies, complies with ANSI standards, and is not “hot”, damaged, or otherwise in need of maintenance or repair; (ix) its functioning or performance has not been adversely affected by a failure or insufficiency of the back haul telecommunications network for communications among the components of the Sensus AMI System; and (x) it has been installed in compliance with the procedures and specifications approved by Customer and Sensus.

C. “Billing Window” for a meter means the four day period commencing one day prior to the relevant billing day for such meter and ending two days after such billing day. The Billing Window for testing purposes shall be agreed by Customer and Sensus.

D. “Customer” means the entity that purchases goods and/or services directly from Sensus.

E. “Effective Date” means the date the Utility Customer signs the Spectrum Lease Agreement between Utility Customer and Sensus.

F. “End User” means any end user of electricity, water, and/or gas (as applicable) that pays Utility Customer for the consumption of electricity, water, and/or gas, as applicable.

G. “Endpoints” mean both (a) Sensus FlexNet meters (with a SmartPoint Module installed); and (b) Sensus SmartPoint Modules which have been installed on a third party meter.

H. “Force Majeure” means an event beyond a party’s reasonable control, including without limitation, acts of God, hurricane, flood, volcano, tsunami, tornado, storm, tempest, mudslide, vandalism, illegal or unauthorized radio frequency interference, strikes, lockouts, or other industrial disturbances, unavailability of component parts of any goods provided hereunder, acts of public enemies, wars, blockades, insurrections, riots, epidemics, earthquakes, fires, restraints or prohibitions by any court, board, department, commission or agency of the United States or any States, any arrests and restraints, civil disturbances and explosion.

I. “In/Out Costs” means any costs and expenses incurred in transporting goods between to and from End User’s premises and any costs and expenses incurred in installing, uninstalling and removing goods.

J. “Meter Data” means the specific metering information, including without limitation, locations and antenna heights, provided to Sensus by Utility Customer in writing prior to the earlier of the; (i) Effective Date; and (ii) the date set forth on the propagation study (collectively, the “Data Date”). The parties recognize and agree that the RF Field Equipment site design and build is based on the specific Meter Data provided to Sensus. For clarity, the Meter Data only contains the information specifically provided to Sensus by the Utility Customer in writing prior to the Data Date. By way of example only (and not as an exhaustive list), the “Meter Data” includes the latitudes and longitudes of each meter, the location of each module either inside or outside (outside is assumed), and, for meters in pits, whether the radio is installed through or under the lid (the assumption is through the lids). New or different metering locations and/ or antenna heights provided after the Data Date are not included as part of the Meter Data.

K. “Ongoing fees ” means any reoccurring monthly or annual fees, including without limitation, fees for software and spectrum leases.

L. “Recurrent RF Field Equipment Fees” means any and all costs, fees, and expenses required to; (i) warrant the RF Field Equipment; and (ii) install and keep the RF Field Equipment located in the field, including without limitation, site procurement and preparation fees, fees related to building poles or towers, tower lease fees, costs of electricity supply, and any local, state, or federal government taxes or charges.

M. “Remote Transceiver” identifies the Sensus standalone, mounted relay device that takes the radio frequency readings from the SmartPoint Modules and relays them directly to the RNI by TCP/IP backhaul communication.

N. “Required RF Field Equipment” means the number, location, and height of the RF Field Equipment set forth in the Certified Propagation Study.

O. “RF Field Equipment” means the FlexNet Base Stations, Echo Transceivers, and Remote Transceivers.

P. “Service Territory” identifies the geographic area where Utility Customer provides electricity, water, and/or gas (as applicable) services to End Users as of the Effective Date. This area will be described in Utility Customer and Sensus’ spectrum lease filing with the FCC.

Q. “Spectrum Lease Agreement” means a written, signed agreement between Sensus and Utility Customer whereby the Utility Customer leases certain spectrum from Sensus. The Spectrum Lease Agreement may be included as part of a larger agreement, such as an AMI Agreement or a Software License and Spectrum Lease Agreement.

R. “Success Percentage” means, of the covered meters in the propagation study,

98.5%.

S. “Test Equipment” means the number of RF Field Equipment and production RNIs set forth in the Certified Propagation Study. The Test Equipment specifically does not include test RNIs or backup RNIs; it only includes production RNIs.

T. “Test Units” means Endpoints that are both; (i) Available Meters throughout the entire test period; and (ii) are covered meters, as depicted on the Certified Propagation Study.

U. “Unavailable Meters” include meters with sockets with power cut at the pole, meters that are booted on the line side, sockets that are not provided power due to a power delivery system failure, meters with tamper, theft or other human induced failures that render the meter or SmartPoint Module incapable of providing a read, a Force Majeure event induced failures of the power delivery system, socket or meter, and/ or any system or meter maintenance issue that precludes the meter from transmitting its message to the network. Examples of Unavailable Meters include: (i) Cut At Pole:
a meter for which power has been turned off to the socket by Utility Customer; (ii) Booted on Line Side: nominally a meter for which power has been turned off by placing “boots” in the socket from which the power to the meter has effectively been turned off; (iii) Failed or flawed power delivery to the meter socket: Utility Customer power generation, distribution or delivery system failure that has effectively turned off power to the socket and/or meter; (iv) Tampered Meters: sockets, meters or distribution assets that have been modified by unauthorized personnel rendering the meter incapable of providing accurate usage readings from that meter; (v) Broken TouchCoupler unit: the TouchCoupler unit is damaged by intentional or unintentional acts; (vi) Broken Clip: the clip that holds the TouchCoupler unit into the radio package housing is broken and the unit cannot complete the inductive electrical connection; (vii) Improper installation of the TouchCoupler unit: the TouchCoupler unit is not pushed all the way into the housing clip causing the unit to not be able to complete the inductive electrical connection; (viii) Unit not installed through the pit lid: the unit is not installed with the antenna positioned through the pit lid and properly secured with the retaining nut. The radio unit must also be securely attached to the antenna section; (ix) Radio unit not securely attached to the Antenna unit: The water-proof SmartPoint Module housing is not properly installed and secured to the antenna unit; (x) Damaged antenna: the unit’s antenna is damaged by intentional or unintentional acts; (xi) Damaged radio package: the unit’s water-proof radio package is damaged by intentional or unintentional acts; (xii) Data Base errors: the unit is removed from the system but not updated in the database. The unit is still shown as in the system when in fact has been removed; (xiii) Phantom Units: the unit is removed from the system but is still transmitting and being heard by the system; and (xiv) Other Installation Defect: the unit is otherwise installed improperly so that it does not communicate with the FlexNet Base Station.

V. “Utility Customer ” means the utility customer that uses the Sensus goods and services in its AMI System regardless of whether such goods and services are purchased directly from Sensus or from a Sensus authorized distributor. For clarity, the Utility Customer is also the Customer if the Utility Customer purchases directly from Sensus.

W. “Warranty End Date” means the earlier of; (i) the third anniversary of the Effective Date; (ii) successful completion of the applicable Performance Test Standards; or (iii) the termination or expiration of the Spectrum Lease Agreement between Utility Customer and Sensus.
8601 Six Forks Road, Suite 700
Raleigh, NC 27615
1-800-638-3748
Sensus AMI System Performance Warranty

Page 222 ends