Location Description Mayor, City Clerk, and City Manager Offices Observed Sep 28, 2023 by [email protected] Site Conditions A tactile sign is not provided on the latch side of the door.
Resolution
Provide signage with print of compliant character height and provide raised lettering. Raised lettering shall include Braille. Tactile characters shall be located 48" minimum measured from the baseline of the lowest tactile character, and 60" maximum above the finish floor or ground surface measured from the baseline of the highest visual character. Visual characters shall be 40" minimum above grade. The minimum character height shall be 5/8" when the horizontal viewing distance is less than 72" and the signage height to baseline of the character from ground is from 40" to 70". Where the baseline of the characters is located between 70" and 120" from the ground, and the horizontal viewing distance less than 180", the minimum character height is 2".
Priority 4
Quantity
3 EA
Unit Cost
69.00 Total Cost
$ 207
382 Submittal: November 1, 2024
Photos for Barrier ID: AX394370
383 Submittal: November 1, 2024
Barrier ID: AX394382
City of Industry City Hall INTERIOR
Assembly Kitchen
Type Refrigerator/Freezer
ADA Standard 804.6.6
Barrier Detail
The combination refrigerator/freezer does not have at least 50% of the freezer space 54" maximum above the finish floor or ground.
Location Description Breakroom 114
Observed Sep 27, 2023 by [email protected] Site Conditions
The refrigerator has a bottom freezer with approximately 25% of the freezer in reach range and 75% of the refrigerator within reach range.
Resolution
Replace the combination refrigerator/freezer with a model that has at least 50% of the freezer space 54" maximum above the finish floor or ground.
Priority 5
Quantity
1 EA
Unit Cost
1,250.00
Total Cost
$ 1,250
384 Submittal: November 1, 2024
Photos for Barrier ID: AX394382
385 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
COMMUNITY SERVICES CENTER
COMMUNITY SERVICES CENTER PAGE FACILITIES
386 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Site Plan:
COMMUNITY SERVICES CENTER PAGE FACILITIES
387 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Floor Plan:
COMMUNITY SERVICES CENTER PAGE FACILITIES
388 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
FACILITY: COMMUNITY SERVICES CENTER
Facility Description:
Facility was constructed in the year .
Facility Address:
This facility is used for the following programs:
1974
Youth Community Center
Dojo
Boxing
Athletic Center
205 N. Hudson Ave.
COMMUNITY SERVICES CENTER PAGE FACILITIES
389 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CSC-01
Facility: Community Services
Center
Deficiency:
Code References:
2016 CBC 11B-502.8
There is no tow away sign provided at the entrance to the parking lot.
Recommended Remediation:
Install a Caltrans R-100B sign at the entrance to the parking lot.
Floor/Area: Parking
Room/Spot: Lot Entrance
Priority: 5 Estimated Direct Cost: $500
Site Elements Parking
Tow Away Signage
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:D
Category Parking Precedence 1 Year 1 Cost with GC (30%): $650 Comment #: CSC-02
Facility: Community Services
Center
Deficiency:
Code References:
2016 CBC 11B-502.6
There is no sign indicating 'Minimum Fine' nor is there a compliant Van accessible stall.
Recommended Remediation:
Install the "Minimum Fine $250", and "Van Accessible.
Recommend removing the current sign and replace it with one without the word "Handicap".
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $500
Site Elements Parking
Identification Signs
Measurement: 1 count
502.6 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.2(5)(b)
Minimum Fine
Severity:C
Category Parking Precedence 1 Year 1 Cost with GC (30%): $650
COMMUNITY SERVICES CENTER PAGE FACILITIES
390 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CSC-03
Facility: Community Services
Center
Deficiency:
Code References:
2016 CBC 11B-502.2
The Accessible Van Stall is less than 144 inches wide and the adjacent access aisle is less than 96 inches wide.
Recommended Remediation:
Reconfigure spaces by repainting lines. Dimensions to be measured to centerline. The accessible stall must be Van Accessible.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 57 inches
502.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.2(5)(b)
Van Width
Severity:C
Category Parking Precedence 1 Year 1 Cost with GC (30%): $975 Comment #: CSC-04
Facility: Community Services
Center
Deficiency:
Code References:
2016 CBC 11B-303.2
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Path of Travel
Room/Spot: Entrance
Priority: 1 Estimated Direct Cost: $1,620
Site Elements Exterior Access Route
Surface Continuity
Measurement: 1 count
303.2/303.3 Quantity: 18 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 1 Year 1 Cost with GC (30%): $2,106 Route
COMMUNITY SERVICES CENTER PAGE FACILITIES
391 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
COUNCIL CHAMBERS
COUNCIL CHAMBERS PAGE FACILITIES
392 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Site Plan:
COUNCIL CHAMBERS PAGE FACILITIES
393 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Floor Plan:
COUNCIL CHAMBERS PAGE FACILITIES
394 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
FACILITY: COUNCIL CHAMBERS
Facility Description:
Facility was constructed in the year .
Facility Address:
This facility is used for the following programs:
1975
Council Meetings
City Agency Meetings
etc.
Rented space for business’ to hold training and seminars 15651 East Stafford
COUNCIL CHAMBERS PAGE FACILITIES
395 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CC-01
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The access aisle does not provide the words "No Parking" (or they are faded) in minimum 12 inch (305 mm) high lettering visible from the adjacent vehicular way.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking Lot
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 2 Year 1 Cost with GC (30%): $1,950 Comment #: CC-02
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking Lot
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 2 Year 1 Cost with GC (30%): $1,950
COUNCIL CHAMBERS PAGE FACILITIES
396 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CC-03
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-502.2
The accessible car stall is less than 108 inches (9 ft. or 2743 mm) wide.
Recommended Remediation:
Repaint the car stall markings to provide compliant width.
Dimensions to be measured to centerline. Black out the blue stall marking and repaint the white one blue. ADA is compliant at 8 feet.
Floor/Area: Parking Lot
Room/Spot: Accessible Parking
Priority: 5 Estimated Direct Cost: $700
Site Elements Parking
Accessible Car Stall
Measurement: 104 inches
N/A Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Width
Severity:D
Category Parking Precedence 2 Year 1 Cost with GC (30%): $910 Comment #: CC-04
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA for the old Accessible stall is faded.
Recommended Remediation:
Remove the existing ISA. A potential solution to this lot is to remove the lone van accessible stall and restripe old stall and access aisle to be van accessible and compliant. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking Lot
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $400
Site Elements Parking
ISA Marking
Measurement: 1 count
502.3.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Old ISA Marking
Severity:C
Category Parking Precedence 2 Year 1 Cost with GC (30%): $520
COUNCIL CHAMBERS PAGE FACILITIES
397 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CC-05
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-502.6
The bottom of the sign is lower than 60 inches (1524 mm) above the finished floor.
Recommended Remediation:
Adjust sign to a compliant height.
Floor/Area: Parking Lot
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $500
Site Elements Parking
Signage
Measurement: 35 inches
502.6 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Parking Precedence 2 Year 1 Cost with GC (30%): $650 Comment #: CC-06
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Floor/Area: Parking Lot
Room/Spot: Accessible Parking
Priority: 5 Estimated Direct Cost: $1,000
Site Elements Parking
Identification Signs
Measurement: 2 count
N/A Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:D
Category Parking Precedence 2 Year 1 Cost with GC (30%): $1,300
COUNCIL CHAMBERS PAGE FACILITIES
398 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CC-07
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking Lot
Room/Spot: Path of Travel
Priority: 5 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Curb Ramp
Measurement: 5 feet
N/A Quantity: 5 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:D
Category Exterior Access Precedence 2 Year 1 Cost with GC (30%): $468 Route
Comment #: CC-08
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-406.2, 2016 CBC 11B-403.3
The running slope of the curb ramp exceeds the allowable 1:12 (8.33%) grade. Additional ramp features are noncompliant.
Recommended Remediation:
Remove and dispose of noncompliant curb ramp and regrade and replace with a parallel curb ramp. Include a compliant path of travel with cross slope less than 2% between adjacent paths.
Floor/Area: Parking Lot
Room/Spot: Path of Travel
Priority: 1 Estimated Direct Cost: $2,250
Site Elements Exterior Access Route
Curb Ramp
Measurement: 9.3 % grade
405.2 Quantity: 150 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Running Slope
Severity:C
Category Exterior Access Precedence 2 Year 1 Cost with GC (30%): $2,925 Route
COUNCIL CHAMBERS PAGE FACILITIES
399 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CC-09
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-504.4.1
Warning stripes are not provided on every step of an exterior staircase.
Recommended Remediation:
Add contrasting stripes between 2 and 4 inches wide across the entire width of each tread and the upper approach. Floor/Area: Entrance Room/Spot: Stairs
Priority: 5 Estimated Direct Cost: $720
Site Elements Exterior Access Route
Stairs
Measurement: 2 count
N/A Quantity: 120 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Warning Stripes
Severity:D
Category Exterior Access Precedence 2 Year 1 Cost with GC (30%): $936 Route
Comment #: CC-10
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-505.4
The stairs do not provide compliant handrails.
Recommended Remediation:
Install compliant handrails and extensions on both sides of the stairs. Floor/Area: Entrance
Room/Spot: Stairs
Priority: 1 Estimated Direct Cost: $4,600
Site Elements Exterior Access Route
Stairs
Measurement: 2 count
505.2 Quantity: 40 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Handrails
Severity:C
Category Exterior Access Precedence 2 Year 1 Cost with GC (30%): $5,980 Route
COUNCIL CHAMBERS PAGE FACILITIES
400 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CC-11
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-303.2
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Entrance
Room/Spot: Site arrival point
Priority: 1 Estimated Direct Cost: $540
Site Elements Exterior Access Route
Surface Continuity
Measurement: .75 inches
303.2/303.3 Quantity: 6 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 2 Year 1 Cost with GC (30%): $702 Route
Comment #: CC-12
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-216.3
The ramp is not visible from the site arrival point and directional signage is not provided.
Recommended Remediation:
Install directional signage that includes the ISA at the site arrival point and each POT fork along the rout to the accessible entrance. Install two directional signs at the base of the ramp near accessible parking and at the stairs.
Floor/Area: Entrance
Room/Spot: Site arrival point
Priority: 1 Estimated Direct Cost: $1,922
Site Elements Exterior Access Route
Signage
Measurement: 1 count
216.6 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3 (16B)
Directional Signage
Severity:C
Category Exterior Access Precedence 2 Year 1 Cost with GC (30%): $2,499 Route
COUNCIL CHAMBERS PAGE FACILITIES
401 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CC-13
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-216.6
No signage indicating the accessible entrance to the facility is provided.
Recommended Remediation:
Install a sign that includes the ISA at the accessible entrance to the facility. Include a tactile facility identification sign. Floor/Area: Entrance Room/Spot: Site arrival point
Priority: 1 Estimated Direct Cost: $1,000
Site Elements Entrance
Signage
Measurement: 1 count
216.6 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16B)
Identification Signs
Severity:C
Category Entrance Precedence 2 Year 1 Cost with GC (30%): $1,300 Comment #: CC-16
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-603
The women's restroom is not accessible due to accessible stall being less than 60 inches wide and does not provide clearance.
Additionally, the lavatory area is noncompliant and a variety of other issues.
Recommended Remediation:
The entire restroom needs to be demolished and an accessible restroom needs to be engineered in its place. A) Recommend making both restrooms gender neutral. B) Reconfigure 1 restroom to be accessible. C) Provide signage at non-accessible restroom directing to accessible restroom. D) Provide ISA on accessible restroom.
Floor/Area: Lobby
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $5,000
Public Toilet Rooms General Accessibility
Clearance Space
Measurement: 1 count
603.2.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.2 General
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $6,500 Accessibility
COUNCIL CHAMBERS PAGE FACILITIES
402 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CC-17
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-603
The men's restroom is not accessible due to accessible stall being less than 60 inches wide and the urinal does not provide clearance. Additionally, the lavatory area is noncompliant and a variety of other issues.
Recommended Remediation:
The entire restroom needs to be demolished and an accessible restroom needs to be engineered in its place. A) Recommend making both restrooms gender neutral. B) Reconfigure 1 restroom to be accessible. C) Provide signage at non-accessible restroom directing to accessible restroom. D) Provide ISA on accessible restroom.
Floor/Area: Lobby
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $5,000
Public Toilet Rooms General Accessibility
Clearance Space
Measurement: 1 count
603.2.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.2/4.1.2(7)(c)
General
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $6,500 Accessibility
Comment #: CC-14
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-404.2.9
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace door closers. Install a kick plate that provides a smooth surface on the bottom 10 inches of the door. Include a tactile exit sign.
Floor/Area: Lobby
Room/Spot: Entrance
Priority: 1 Estimated Direct Cost: $1,991
Entrance Doors, Doorways,
Door Operation Gates
Measurement: 12 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $2,588 Gates
COUNCIL CHAMBERS PAGE FACILITIES
403 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CC-18
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 1011.4/11B-216.4
There is no provided tactile exit sign at the doorway leading to a grade level exit.
Recommended Remediation:
Install one tactile exit sign where illuminated exit signs are provided. The sign by the rodeo office needs to say “Exit Stair Down” with a directional sign saying “ Accessible Exit” indicating the other exit.
Floor/Area: Meeting Room
Room/Spot: Exits
Priority: 3 Estimated Direct Cost: $1,922
Rooms and Spaces Interior Doors
Signage
Measurement: 2 count
216.4/703.4.1&2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16(a))
Tactile Exit Sign
Severity:C
Category Interior Doors Precedence 8 Year 3 Cost with GC (30%): $2,499 Comment #: CC-15
Facility: Council Chambers
Deficiency:
Code References:
2016 CBC 11B-604.3.1
The men's restroom is not accessible due to accessible stall being less than 60 inches wide and the urinal does not provide clearance. Additionally, the lavatory area is noncompliant.
Recommended Remediation:
The entire restroom needs to be demolished and an accessible restroom needs to be engineered in its place. A) Recommend making both restrooms gender neutral. B) Reconfigure 1 restroom to be accessible. C) Provide signage at non-accessible restroom directing to accessible restroom. D) Provide ISA on accessible restroom.
Floor/Area: Lobby
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $0
Public Toilet Rooms Toilet Compartment
Clearance Space (Stalls)
Measurement: 1 count
Quantity: 1 Restroo
m
604.2/604.8
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.16.2 Width
Severity:C
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $0 (Stalls)
COUNCIL CHAMBERS PAGE FACILITIES
404 Submittal: November 1, 2024
Barrier ID: AX394088
City of Industry Council Chambers INTERIOR
Assembly Entrance to Building
Type Building Entrance-Door
ADA Standard CBD Chap 11B-404.2.9
Barrier Detail
CALIFORNIA: The non-fire, hinged accessible exterior door takes more than 5#s of pressure to operate.
Location Description Council Chamber Exterior Exit
Observed Sep 27, 2023 by [email protected] Site Conditions The opening force is 15 pounds.
Resolution
Adjust the closer or replace with an exterior non-fire door that requires no more 5 pounds of force for pushing or pulling the door open. This barrier must be removed in conjunction with barrier ID 394089. The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum. These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door or gate in a closed position.
Note: Fire doors shall have a minimum opening force allowable by the appropriate administrative authority.
Priority 1
Quantity
1 EA
Unit Cost
457.50
Total Cost
$ 458
Photos for Barrier ID: AX394088
405 Submittal: November 1, 2024
Barrier ID: AX394089
City of Industry Council Chambers INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.8
Barrier Detail
The accessible door with door closer has a sweep period of less than 5 seconds from 90 degrees to a position 12 degrees from latch.
Location Description Council Chamber Exterior Exit
Observed Sep 27, 2023 by [email protected] Site Conditions
The closing speed is 2.46 seconds from the 90 degrees position to a position 12 degrees from the latch.
Resolution
Adjust closer or remove and replace closer to ensure that the door has a closure time of at least 5 seconds within 12 degrees of the latch. This barrier must be removed in conjunction with barrier ID 394088. The cost of this barrier removal is covered under ID 394088 and therefore, the cost of this ID is shown as $0. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Priority 1
Quantity
1 EA
Unit Cost
0.00 Total Cost
$ 0
Photos for Barrier ID: AX394089
406 Submittal: November 1, 2024
Barrier ID: AX394090
City of Industry Council Chambers INTERIOR
Assembly Interior Access Route
Type Interior Access Route
ADA Standard 403.3
Barrier Detail The interior accessible route has non-compliant slopes.
Location Description Council Chambers
Observed Sep 27, 2023 by [email protected] Site Conditions The accessible route to the podium has cross slopes up to 6.4%.
Resolution
The floor surface should be graded to maximum 1:20 (5%) running slope and maximum 1:50 (2%) cross slope.
An accessible route has maximum 1:20 (5%) running slope and maximum 1:50 (2%) cross slope. [EXCEPTION:
Cross slopes not exceeding 1:48 (2.08%) are permitted.] The clear width of walking surfaces shall be 36" minimum. [EXCEPTION: The clear width shall be permitted to be reduced to 32" minimum for a length of 24" maximum provided that reduced width segments are separated by segments that are 48" long minimum and 36" wide minimum.] Where grading to maximum running slope of 1:20 (5% running slope) is not possible, provide a compliant ramped surface within the walkway with maximum slope 1:12 (8.33%) and maximum ramp run rise of 6" without handrails. If a ramped surface with running slopes greater than 1:20 (5%) and maximum 1:12 (8.33%) rises more than 6", handrails are required. The cost estimate for this barrier removal is based on grading the running slope to maximum 1:20 (5%). The quantity and order of magnitude cost estimate provided for this barrier are limited to the extent of the area identified as non-compliant. Additional costs that may be associated with removal of the barrier are not included.
Priority 1
Quantity
80 SF
Unit Cost
78.69 Total Cost
$ 6,295
Photos for Barrier ID: AX394090
407 Submittal: November 1, 2024
Barrier ID: AX394093
City of Industry Council Chambers INTERIOR
Assembly Interior Access Route
Type Interior Access Route
ADA Standard California Building Code Chap 11B-403.5.1, Exception 4 Barrier Detail CALIFORNIA: The width of the aisle is not compliant.
Location Description Council Chambers
Observed Sep 27, 2023 by [email protected] Site Conditions
The accessible route to the podium has a clear width of 32" between the seats and the rail.
Resolution
Widen the walkway aisle to minimum 44" clear width. The clear width for aisles shall be 36" minimum if serving elements on only one side, and 44" minimum if serving elements on both sides.
Priority 1
Quantity
80 SF
Unit Cost
78.69 Total Cost
$ 6,295
Photos for Barrier ID: AX394093
408 Submittal: November 1, 2024
Barrier ID: AX394094
City of Industry Council Chambers INTERIOR
Assembly Interior Access Route
Type Ramp
ADA Standard 405.2
Barrier Detail The ramp running slope exceeds 1:12 (8.33%).
Location Description Council Chambers
Observed Sep 27, 2023 by [email protected] Site Conditions
The ramp has running slopes from 8.8% to 10.0% with a rise of approximately 27".
Resolution
Remove and replace areas of the ramp run to provide a ramp run with maximum slopes 1:12 (8.33%). The cross slope of ramp surfaces shall be no greater than 1:50 (2.0%). [EXCEPTION: Cross slopes not greater than 1:48 are permitted.] Ramp runs shall have a running slope not steeper than 1:12. [EXCEPTION: In existing sites, buildings, and facilities, ramps shall be permitted to have running slopes steeper than 1:12 where such slopes are necessary due to space limitations. Maximum Ramp Slope and Rise for Existing Sites, Buildings, and Facilities: Slope-Steeper than 1:10 but not steeper than 1:8; Maximum Rise is 3"; Steeper than 1:12 but not steeper than 1:10; Maximum Rise is 6". A slope steeper than 1:8 is prohibited.] Priority 1
Quantity
27 LF
Unit Cost
827.50
Total Cost
$ 22,343
409 Submittal: November 1, 2024
Photos for Barrier ID: AX394094
410 Submittal: November 1, 2024
Barrier ID: AX398693
City of Industry Council Chambers INTERIOR
Assembly Interior Access Route
Type Ramp
ADA Standard 405.8 and 505
Barrier Detail The ramp run rises 6" or greater but has no handrails.
Location Description Council Chambers
Observed Sep 27, 2023 by [email protected] Site Conditions
The ramp has a rise of approximately 27" and does not have handrails. Per the exception for assembly areas handrails are only required on one side of the ramp.
Resolution
Install compliant handrails on each side of ramp.Handrails are required on ramp runs with a rise greater than 6".
Handrails are not required on walking surfaces with running slopes less than 1:20. Handrails shall be provided on both sides of ramps. [EXCEPTION: In assembly areas, handrails shall not be required on both sides of aisle ramps where a handrail is provided at either side or within the aisle width.] Handrails shall be continuous within the full length of each ramp run. Inside handrails on ramps shall be continuous between runs. [EXCEPTION: In assembly areas, handrails on ramps shall not be required to be continuous in aisles serving seating.] Handrails shall be at a consistent height above the ramp on both sides of the ramp. Tops of gripping surfaces of handrails shall be 34" minimum and 38" maximum vertically above ramp surfaces. [ADVISORY: The requirements for ramp handrails are for adults. When children are the principal users in a building or facility (e.g., elementary schools), a second set of handrails at an appropriate height can assist them and aid in preventing accidents. A maximum height of 28", measured to the top of the gripping surface from the ramp surface or stair nosing, is recommended for handrails designed for children. Sufficient vertical clearance between upper and lower handrails, 9" minimum, should be provided to help prevent entrapment.] Clearance between handrail gripping surfaces and adjacent surfaces shall be 1-1/2" minimum. Handrail gripping surfaces shall be continuous along their length and shall not be obstructed along their tops or sides. The bottoms of handrail gripping surfaces shall not be obstructed for more than 20% of their length. Where provided, horizontal projections shall occur 1-1/2" minimum below the bottom of the handrail gripping surface. [EXCEPTIONS: 1. Where handrails are provided along walking surfaces with slopes not steeper than 1:20, the bottoms of handrail gripping surfaces shall be permitted to be obstructed along their entire length where they are integral to crash rails or bumper guards. 2. The distance between horizontal projections and the bottom of the gripping surface shall be permitted to be reduced by 1/8" for each 1/2" of additional handrail perimeter dimension that exceeds 4".] Handrail gripping surfaces with a circular cross section shall have an outside diameter of 1-1/4" minimum and 2" maximum. Handrail gripping surfaces with a non-circular cross section shall have a perimeter dimension of 4" minimum and 6-1/4" maximum, and a crosssection dimension of 2-1/4" maximum. Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges. Handrails shall not rotate within their fittings.
Handrail gripping surfaces shall extend beyond and in the same direction of ramp runs. [EXCEPTIONS: 1.
Extensions shall not be required for continuous handrails at the inside turn of switchback or dogleg ramps AND
3. In alterations, full extensions of handrails shall not be required where such extensions would be hazardous due to plan configuration.] Ramp handrails shall extend horizontally above the landing for 12" minimum beyond the top and bottom of ramp runs. Extensions shall return to a wall, guard, or the landing surface, or shall be continuous to the handrail of an adjacent ramp run. Edge Protection: A curb or barrier shall be provided that prevents the passage of a 4" diameter sphere, where any portion of the sphere is within 4" of the finish floor or ground surface, or the surface of the ramp shall extend 12" minimum beyond the handrail. [EXCEPTIONS: 1.
Edge protection is not required on ramps that are not required to have handrails and curb ramps with flares. 2.
Edge protection is not required on the sides of ramp landings servings an adjoining ramp run. 3. Edge protection shall not be required on the sides of ramp landings having a vertical drop-off of ½" maximum within 10" horizontally of the minimum landing area.]
411 Submittal: November 1, 2024
Priority 1
Quantity
29 LF
Unit Cost
300.00
Total Cost
$ 8,700
Photos for Barrier ID: AX398693
412 Submittal: November 1, 2024
Barrier ID: AX394084
City of Industry Council Chambers INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.8
Barrier Detail
The accessible door with door closer has a sweep period of less than 5 seconds from 90 degrees to a position 12 degrees from latch.
Location Description Council Chambers Entry
Observed Sep 27, 2023 by [email protected] Site Conditions
The closing speed is 4.09 seconds from the 90 degrees position to a position 12 degrees from the latch.
Resolution
Adjust closer or remove and replace closer to ensure that the door has a closure time of at least 5 seconds within 12 degrees of the latch. This barrier must be removed in conjunction with barrier ID 394085. The cost of this barrier removal is covered under ID 394085 and therefore, the cost of this ID is shown as $0. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Priority 1
Quantity
1 EA
Unit Cost
0.00 Total Cost
$ 0
Photos for Barrier ID: AX394084
413 Submittal: November 1, 2024
Barrier ID: AX394085
City of Industry Council Chambers INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.9
Barrier Detail
The opening force required to open the accessible, hinged, non-fire door is more than 5 pounds.
Location Description Council Chambers Entry
Observed Sep 27, 2023 by [email protected] Site Conditions The opening force is 9 pounds.
Resolution
Adjust the closer or replace with a door that requires no more than 5 pounds of force for pushing or pulling the door open. This barrier must be removed in conjunction with barrier ID 394084. The force at the latch, the force to set the door in motion, and the force to fully open the door shall be maximum 5 pounds. These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door or gate in a closed position.
Priority 1
Quantity
1 EA
Unit Cost
457.50
Total Cost
$ 458
Photos for Barrier ID: AX394085
414 Submittal: November 1, 2024
Barrier ID: AX394095
City of Industry Council Chambers INTERIOR
Assembly Interior Access Route
Type Controls And Dispensers
ADA Standard 305
Barrier Detail Clear space is not provided at the control or operating mechanism.
Location Description Council Chambers Podium
Observed Sep 27, 2023 by [email protected] Site Conditions The clear space at the podium has a slope of 6.6%.
Resolution
Provide compliant clear floor space at each control and operating mechanism that allows a forward or a parallel approach. The clear floor or ground space shall be 30" minimum by 48" minimum. One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space.
Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided. For a forward approach, alcoves shall be 36" wide minimum where the depth exceeds 24". For a parallel approach, alcoves shall be 60" wide minimum where the depth exceeds 15". Floor or ground surfaces of a clear floor or ground space shall comply. Changes in level are not permitted. [EXCEPTION: Slopes not steeper than 1:48 shall be permitted.] Priority 1
Quantity
1 EA
Unit Cost
2,500.00
Total Cost
$ 2,500
415 Submittal: November 1, 2024
Photos for Barrier ID: AX394095
416 Submittal: November 1, 2024
Barrier ID: AX394115
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Urinal
ADA Standard 305.7.1 & 305.7.2
Barrier Detail
Alcoves are not 36" wide minimum where the depth exceeds 24" with forward approach, or 60" wide minimum with parallel approach and depth exceeding 15".
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The urinal alcove is 35-1/4" wide, where the alcove is approximately 28" deep.
Resolution
Ensure alcoves are 36" wide minimum where the depth exceeds 24" with forward approach, or 60" wide minimum with a parallel approach and where the depth exceeds 15".
Priority 1
Quantity
1 EA
Unit Cost
500.00
Total Cost
$ 500
Photos for Barrier ID: AX394115
417 Submittal: November 1, 2024
Barrier ID: AX394087
City of Industry Council Chambers INTERIOR
Assembly Entrance to Building
Type Building Entrance-Door
ADA Standard 404.2.10
Barrier Detail
The surface of the door within 10 inches of the finish floor or ground for the full width of the door on the push side is not smooth.
Location Description Council Chamber Exterior Exit
Observed Sep 27, 2023 by [email protected] Site Conditions The smooth surface at the bottom of the door on the push side is 4" high.
Resolution
Modify or replace the door to provide a surface of the door within 10 inches of the finish floor or ground for the full width of the door on the push side that is smooth. Swinging door and gate surfaces within 10 inches of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other. Cavities created by added kick plates shall be capped. [EXCEPTIONS: 1. Sliding doors shall not be required to comply. 2. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal shall not be required to meet the 10 inch bottom smooth surface height requirement. 3. Doors and gates that do not extend to within 10 inches of the finish floor or ground shall not be required to comply. 4. Existing doors and gates without smooth surfaces within 10 inches of the finish floor or ground shall not be required to provide smooth surfaces provided that if added kick plates are installed, cavities created by such kick plates are capped,] Priority 2
Quantity
1 EA
Unit Cost
500.00
Total Cost
$ 500
418 Submittal: November 1, 2024
Photos for Barrier ID: AX394087
419 Submittal: November 1, 2024
Barrier ID: AX394086
City of Industry Council Chambers INTERIOR
Assembly Interior Access Route
Type Signage
ADA Standard 216.4.1, 703
Barrier Detail Means of egress exit signs do not have tactile lettering.
Location Description Council Chamber Exterior Exit
Observed Sep 27, 2023 by [email protected] Site Conditions A tactile means of egress sign is not provided.
Resolution
Remove and replace signage with compliant signage. Means of egress require tactile signage (Applies to designated egress stairways, exit doors, areas of refuge) Signs at exit doors shall include tactile signage. Signs shall be installed alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. Where a tactile sign is provided at double doors with two active leafs, the sign shall be located to the right of the right hand door. Where there is no wall space at the latch side of a single door or at the right side of double doors, sign shall be located on the nearest adjacent wall. Signs containing tactile characters shall be located so that a clear floor space of 18" inches minimum by 18" minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degrees open. Tactile sign characters shall be mounted minimum height of 48" and maximum height of 60" from finish floor. Visual characters shall be a minimum height of 40" from finish floor. Where both visual and tactile characters are required, either one sign with both visual and tactile characters, or two separate signs, one with visual, and one with tactile characters, shall be provided. Raised characters shall be complaint and shall be duplicated in Braille. Raised characters shall be as follows: Depth. Raised characters shall be 1/32" minimum above their background. Case. Characters shall be uppercase. Style. Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms. Character Proportions. Characters shall be selected from fonts where the width of the uppercase letter "O" is 55% minimum and 110 % maximum of the height of the uppercase letter "I". Character Height. Character height measured vertically from the baseline of the character shall be 5/8" minimum and 2" maximum based on the height of the uppercase letter "I". [EXCEPTION: Where separate raised and visual characters with the same information are provided, raised character height shall be permitted to be 1/2" minimum.] Priority 2
Quantity
1 EA
Unit Cost
68.75 Total Cost
$ 69
420 Submittal: November 1, 2024
Photos for Barrier ID: AX394086
421 Submittal: November 1, 2024
Barrier ID: AX394091
City of Industry Council Chambers INTERIOR
Assembly Common Areas
Type Assembly Area
ADA Standard 221; 221.1; 221.2.1 thru 3; 221.2.3.1 & 2; 221.3; 802.3 Barrier Detail Assembly areas do not provide wheelchair spaces.
Location Description Council Chambers
Observed Sep 27, 2023 by [email protected] Site Conditions
The assembly area has 48 total seats requiring 2 wheelchair spaces. No wheelchair spaces are provided. The floors have slopes up to 10.4%.
Resolution
Wheelchair spaces shall be provided. A single wheelchair space is minimum 36" wide. Where two wheelchair spaces adjoin, the wheelchair spaces shall be minimum 33" wide. When approached from the front or rear, wheelchair spaces shall be minimum 48" deep. Wheelchair spaces approached from the side shall be minimum 60" deep. One side of the wheelchair space shall connect to, but be separate from, an accessible route and shall not overlap the circulation path. In row seating, at least one companion seat shall be provided adjacent to each required wheelchair space. Number of Wheelchair Spaces in Assembly Areas Number of Seats- Minimum Number of Required Wheelchair Spaces: 4 to 25 requires 1; 26 to 50 requires 2; 51 to 150 requires 4; 151 to 300 requires 5; 301 to 500 requires 6; 501 to 5000 requires 6, plus 1 for each 150, or fraction thereof, between 501 through 5000; 5001 and over requires 36, plus 1 for each 200, or fraction thereof, over 5000. Wheelchair spaces shall provide compliant lines of sight. In providing lines of sight, wheelchair spaces shall be dispersed.
Wheelchair spaces shall provide spectators with choices of seating locations and viewing angles that are substantially equivalent to, or better than, the choices of seating locations and viewing angles available to all other spectators. When the number of wheelchair spaces required has been met, further dispersion shall not be required. Wheelchair spaces shall be dispersed horizontally. [EXCEPTIONS: 1. Horizontal dispersion shall not be required in assembly areas with 300 or fewer seats if the companion seats required and wheelchair spaces are located within the 2nd or 3rd quartile of the total row length. Intermediate aisles shall be included in determining the total row length. If the row length in the 2nd and 3rd quartile of a row is insufficient to accommodate the required number of companion seats and wheelchair spaces, the additional companion seats and wheelchair spaces shall be permitted to be located in the 1st and 4th quartile of the row. 2. In row seating, two wheelchair spaces shall be permitted to be located side-by-side.] Wheelchair spaces shall be dispersed vertically at varying distances from the screen, performance area, or playing field. In addition, wheelchair spaces shall be located in each balcony or mezzanine that is located on an accessible route. [EXCEPTIONS: 1. Vertical dispersion shall not be required in assembly areas with 300 or fewer seats if the wheelchair spaces provide viewing angles that are equivalent to, or better than, the average viewing angle provided in the facility.] Priority 2
Quantity
32 SF
Unit Cost
78.69 Total Cost
$ 2,518
422 Submittal: November 1, 2024
Photos for Barrier ID: AX394091
423 Submittal: November 1, 2024
Barrier ID: AX394092
City of Industry Council Chambers INTERIOR
Assembly Common Areas
Type Assembly Area
ADA Standard 216.10; 219; 706
Barrier Detail An assistive listening system is required, but not provided.
Location Description Council Chambers
Observed Sep 27, 2023 by [email protected] Site Conditions
An assisted listening system with assisted listening devices is not not provided. The assembly area has 48 total seats requiring 2 assisted listening devices.
Resolution
Each assembly area required to provide assistive listening systems shall provide signs informing patrons of the availability of the assistive listening system. Assistive listening signs shall comply and shall include the International Symbol of Access for Hearing Loss. [EXCEPTION: Where ticket offices or windows are provided, signs shall not be required at each assembly area provided that signs are displayed at each ticket office or window informing patrons of the availability of assistive listening systems.] Receivers required for use with an assistive listening system shall include a 1/8" standard mono jack. Receivers required to be hearing-aid compatible shall interface with telecoils in hearing aids through the provision of neck loops. Neck loops and headsets that can be worn as neck loops are compatible with hearing aids. Receivers that are not compatible include earbuds, which may require removal of hearing aids, earphones, and headsets that must be worn over the ear, which can create disruptive interference in the transmission and can be uncomfortable for people wearing hearing aids. Assistive listening systems shall be capable of providing a sound pressure level of 110 dB minimum and 118 dB maximum with a dynamic range on the volume control of 50 dB. The signal-to-noise ratio for internally generated noise in assistive listening systems shall be 18 dB minimum. Peak clipping shall not exceed 18 dB of clipping relative to the peaks of speech. In each assembly area where audible communication is integral to the use of the space, an assistive listening system shall be provided. [EXCEPTION: Other than in courtrooms, assistive listening systems shall not be required where audio amplification is not provided.] Receivers shall be provided for assistive listening systems in each assembly area. Twenty-five percent minimum of receivers provided, but no fewer than two, shall be hearing-aid compatible. [EXCEPTIONS: 1. Where a building contains more than one assembly area and the assembly areas required to provide assistive listening systems are under one management, the total number of required receivers shall be permitted to be calculated according to the total number of seats in the assembly areas in the building provided that all receivers are usable with all systems. 2. Where all seats in an assembly area are served by an induction loop assistive listening system, the minimum number of receivers required to be hearing-aid compatible shall not be required to be provided.] Capacity of Seating in Assembly Area: 50 or less Minimum Number of Required Receivers: 2 Minimum Number of Required Receivers Required to be Hearing-aid Compatible: 2 Capacity of Seating in Assembly Area:
51 to 200 Minimum Number of Required Receivers: 2, plus 1 per 25 seats over 50 seats, or fraction thereof.
Minimum Number of Required Receivers Required to be Hearing-aid Compatible: 2 Capacity of Seating in Assembly Area: 201 to 500 Minimum Number of Required Receivers: 2, plus 1 per 25 seats over 50 seats, or fraction thereof. Minimum Number of Required Receivers Required to be Hearing-aid Compatible: 1 per 4 receivers, or fraction thereof Capacity of Seating in Assembly Area: 501 to 1000 Minimum Number of Required Receivers: 20, plus 1 per 33 seats over 500 seats, or fraction thereof. Minimum Number of Required Receivers Required to be Hearing-aid Compatible: 1 per 4 receivers, or fraction thereof . Capacity of Seating in Assembly Area: 1001 to 2000 Minimum Number of Required Receivers: 35, plus 1 per 50 seats over 1000 seats, or fraction thereof. Minimum Number of Required Receivers Required to be Hearing-aid Compatible: 1 per 4 receivers, or fraction thereof Capacity of Seating in Assembly Area: 2001 and over Minimum Number of Required Receivers:
55 plus 1 per 100 seats over 2000 seats, or fraction thereof. Minimum Number of Required Receivers Required to be Hearing-aid Compatible: 1 per 4 receivers, or fraction thereof 424 Submittal: November 1, 2024
Priority 2
Quantity
2 EA
Unit Cost
312.50
Total Cost
$ 625
Photos for Barrier ID: AX394092
425 Submittal: November 1, 2024
Barrier ID: AX394096
City of Industry Council Chambers INTERIOR
Assembly Interior Access Route
Type Controls And Dispensers
ADA Standard 306, 902.1, 902.2, 902.3, 902.4
Barrier Detail
ADVISORY: The work surface height is not compliant. Knee and toe clearances are not provided.
Location Description Council Chambers Podium
Observed Sep 27, 2023 by [email protected] Site Conditions The top of the podium surface is 39" above the floor.
Resolution
ADVISORY: Provide work surface tables at a compliant height. The tops of work surfaces shall be 28" minimum and 34" maximum above the finish floor or ground. A clear floor space 30" minimum by 48" minimum, positioned for a forward approach with the 30" dimension paralleling the edge of the work surface, shall be provided. Knee and toe clearance shall be provided. Knee Clearance: Space under an element between 9" and 27" above the finish floor or ground shall be considered knee clearance. Knee clearance shall extend 25" maximum under an element at 9" above the finish floor or ground. Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11" deep minimum at 9" above the finish floor or ground, and 8" deep minimum at 27" above the finish floor or ground. Between 9" and 27" above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1" in depth for each 6" in height. Knee clearance shall be 30" wide minimum. Toe Clearance: Space under an element between the finish floor or ground and 9" above the finish floor or ground shall be considered toe clearance. Toe clearance shall extend 25" maximum under an element. Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17" minimum under the element. Space extending greater than 6" beyond the available knee clearance at 9" above the finish floor or ground shall not be considered toe clearance. Toe clearance shall be 30" wide minimum. Examples of work surfaces include writing surfaces, study carrels, student laboratory stations, baby changing, other tables or fixtures for personal grooming.
Priority 2
Quantity
1 EA
Unit Cost
0.00 Total Cost
$ 0
426 Submittal: November 1, 2024
Photos for Barrier ID: AX394096
427 Submittal: November 1, 2024
Barrier ID: AX394116
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom-Unisex
ADA Standard 403.3
Barrier Detail The slope of the floor surface is greater than 2% cross or 5% running Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The restroom floor has a slope of 3.9" at the urinal clear space.
Resolution
Provide a floor surface with slopes no greater than 2% cross or 5% running. Ensure compliant thresholds.
Priority 2
Quantity
25 EA
Unit Cost
78.75 Total Cost
$ 1,969
Photos for Barrier ID: AX394116
428 Submittal: November 1, 2024
Barrier ID: AX394496
City of Industry Council Chambers INTERIOR
Assembly Common Areas
Type Assembly Area
ADA Standard 216.10; 219; 706
Barrier Detail Assistive listening signage is not compliant or is not provided.
Location Description Council Chambers
Observed Sep 27, 2023 by [email protected] Site Conditions Assistive listening signage is not provided.
Resolution
Provide assistive listening signage. Each assembly area required to provide assistive listening systems shall provide signs informing patrons of the availability of the assistive listening system. Assistive listening signs shall comply and shall include the International Symbol of Access for Hearing Loss. [EXCEPTION: Where ticket offices or windows are provided, signs shall not be required at each assembly area provided that signs are displayed at each ticket office or window informing patrons of the availability of assistive listening systems].
Priority 3
Quantity
1 EA
Unit Cost
68.75 Total Cost
$ 69
429 Submittal: November 1, 2024
Photos for Barrier ID: AX394496
430 Submittal: November 1, 2024
Barrier ID: AX394118
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Coat Hook
ADA Standard 213.3.7, 604.8.3, 308
Barrier Detail The coat hook is not within an allowable reach range.
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The coat hook is 58-1/2" above the floor.
Resolution
Install the coat hook within an allowable reach range. Unobstructed Forward Reach: Where a forward reach is unobstructed, the high forward reach shall be 48" maximum and the low forward reach shall be 15" minimum above the finish floor or ground. Obstructed High Forward Reach: Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48" maximum where the reach depth is 20" maximum. Where the reach depth exceeds 20", the high forward reach shall be 44" maximum and the reach depth shall be 25" maximum. Unobstructed Side Reach: Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48" maximum and the low side reach shall be 15" minimum above the finish floor or ground. [EXCEPTION: An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10" maximum.] Obstructed High Side Reach: Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34" maximum and the depth of the obstruction shall be 24" maximum. The high side reach shall be 48" maximum for a reach depth of 10" maximum. Where the reach depth exceeds 10", the high side reach shall be 46" maximum for a reach depth of 24" maximum. [ADVISORY for Children's Forward or Side Reach Ranges: High reach (maximum): 36" for ages 3 to 4; 40" for ages 5 to 8; and 44" for ages 9 to 12. Low reach (minimum): 20" for ages 3 to 4; 18" for ages 5 to 8; and 16" for ages 9 to 12.]
Priority 3
Quantity
1 EA
Unit Cost
143.75
Total Cost
$ 144
431 Submittal: November 1, 2024
Photos for Barrier ID: AX394118
432 Submittal: November 1, 2024
Barrier ID: AX394111
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Door
ADA Standard 404.2.9
Barrier Detail
The force required to open the interior, hinged, non-fire door is more than 5 pounds.
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The opening force is 15 pounds.
Resolution
Adjust closer or replace with an closer that requires no more 5 pounds of force to stop the door motion. This barrier must be removed in conjunction with barrier ID 394112. The cost of this barrier removal is covered under ID 394112 and therefore, the cost of this ID is shown as $0. The maximum force for pushing or pulling open a door shall be for interior hinged doors: 5 lbs (22.2N). The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum. These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door or gate in a closed position. Note: Fire doors shall have a minimum opening force allowable by the appropriate administrative authority.
Priority 3
Quantity
1 EA
Unit Cost
0.00 Total Cost
$ 0
Photos for Barrier ID: AX394111
433 Submittal: November 1, 2024
Barrier ID: AX394112
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Door
ADA Standard 404.2.8
Barrier Detail
The accessible door with door closer has a sweep period of less than 5 seconds from 90 degrees to a position 12 degrees from latch.
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
The closing speed is 2.45 seconds from 90 degrees to a position 12 degrees from latch.
Resolution
Adjust closer or remove and replace closer to ensure that the door has a closure time of at least 5 seconds within 12 degrees of the latch. This barrier must be removed in conjunction with barrier ID 394111. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Priority 3
Quantity
1 EA
Unit Cost
457.50
Total Cost
$ 458
Photos for Barrier ID: AX394112
434 Submittal: November 1, 2024
Barrier ID: AX394113
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Door
ADA Standard 404.2; Table 404.2.4.1
Barrier Detail
The pull side of the accessible door does not have the required maneuvering clearances.
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
For an approach from the latch side on the pull side the maneuvering depth is 50". The door has a closure.
Resolution
Redesign to provide the required maneuvering clearance at the pull side of the door. The required depth of the maneuvering clearance is 54" minimum. The required side clearance is 24" minimum on the latch side of the door. Maneuvering clearance shall extend the full width of the doorway and the required latch side clearance.
Floor or ground space within the required maneuvering clearance shall be maximum 1:48 (2.08%) slope.
Changes in level are not permitted.
Priority 3
Quantity
1 EA
Unit Cost
1,562.50
Total Cost
$ 1,563
Photos for Barrier ID: AX394113
435 Submittal: November 1, 2024
Barrier ID: AX394119
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Lavatory
ADA Standard CBC Chap 11B-213, 306, 606
Barrier Detail
CALIFORNIA: The lavatory does not have the required knee and toe clearance.
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The lavatory apron and knee clearance is 26-1/4" above the floor.
Resolution
Provide at least 10% but no fewer than one lavatory with compliant knee and toe clearance. The lavatory shall maintain the maximum allowable height of 34" to the rim of the sink. The maximum allowable exterior bowl depth is 6-1/2". A compliant clear floor space of minimum 30" wide centered on the lavatory and minimum 48" deep, positioned for a forward approach, shall be provided. Space under an element between 9" and 29" above the finish floor or ground shall be considered knee clearance and shall comply. Knee clearance shall be 11" deep minimum at 9" above the finish floor or ground, and 8" deep minimum at 27" above the finish floor. The bottom of the front of the lavatory shall be minimum 29" above the finish floor. Knee clearance reduction is not allowed. Toe clearance shall be minimum 25" horizontal depth between the finish floor and 9" AFF. Knee and toe clearance shall be 30" wide minimum and centered on the lavatory. A compliant clear floor space, positioned for a forward approach, and compliant knee and toe clearance shall be provided. [EXCEPTIONS: 1. Toe clearance shall extend 19" maximum under lavatories 2. A lavatory in a toilet room or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to provide knee and toe clearance. 3. In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the fixture; (b) the finish floor extends under the cabinetry; and (c) the walls behind and surrounding the cabinetry are finished. 4. A knee clearance of 24" minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31" maximum above the finish floor or ground. 5. A parallel approach complying with 305 shall be permitted to lavatories and sinks used primarily by children 5 years and younger.6. The dip of the overflow shall not be considered in determining knee and toe clearances. 7. No more than one bowl of a multi-bowl sink shall be required to provide knee and toe clearance.]
Priority 3
Quantity
1 EA
Unit Cost
900.00
Total Cost
$ 900
436 Submittal: November 1, 2024
Photos for Barrier ID: AX394119
437 Submittal: November 1, 2024
Barrier ID: AX394120
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Lavatory
ADA Standard 606.4; 309
Barrier Detail The lavatory faucet hardware is not compliant.
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
The operable part of the lavatory faucet requires tight grasping and twisting of the wrist to operate.
Resolution
Provide push/lever hardware for the faucet. Replace faucet operating hardware with compliant handles.
Operable parts, such as faucet hardware, shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 pounds (22.2 N) maximum. Hand-operated metering faucets shall remain open for 10 seconds minimum. Provide a minimum of one accessible sink with push/lever hardware.
Priority 3
Quantity
1 EA
Unit Cost
693.75
Total Cost
$ 694
Photos for Barrier ID: AX394120
438 Submittal: November 1, 2024
Barrier ID: AX394114
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Toilet Stall
ADA Standard
309, 404.2.7, 604.5.1, 604.6, 604.7, 604.8.1.1, 604.8.1.2, 604.8.1.5, 604.9, 609.3 Barrier Detail A wheelchair stall is not provided in a multi-user restroom.
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions A wheelchair stall is not provided in the multi-user restroom. 439 Submittal: November 1, 2024
Resolution
Provide a compliant wheelchair stall with compliant elements in the multi-user restroom. Wheelchair accessible compartments with floor mounted water closets shall be 60" wide minimum measured perpendicular to the side wall and 59" deep minimum, measured perpendicular to the rear wall. Wheelchair accessible compartments with wall mounted water closets shall be 60" wide minimum measured perpendicular to the side wall and 56" deep minimum, measured perpendicular to the rear wall. Wheelchair accessible compartments for children's use (ages 3 through 12) shall be 60" wide minimum measured perpendicular to the side wall, and 59" deep minimum for wall hung and floor mounted water closets measured perpendicular to the rear wall.In addition, clear space of minimum 30" by 48" must be provided within the clearance area for transfer from a wheelchair. The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be 16 minimum to 18" maximum from the side wall or partition. Water closets shall be arranged for a left-hand or right-hand approach. The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space. No other fixtures or obstructions, such as lavatories, shall be located within the required water closet clearance. Install a flush control on the open side of the water closet. Flush controls shall be hand operated or automatic. Hand operated flush controls shall be within a compliant reach range. Install compliant grab bars. Horizontal grab bars shall be installed at a consistent height above finish floor to the top of the gripping surface. The top of the gripping surface shall be minimum 33" and maximum 36" above finish floor. The rear wall grab bar shall be 36" long minimum and extend from the centerline of the water closet 12" minimum on one side and 24" minimum on the other side. [EXCEPTIONS: 1. The rear grab bar shall be permitted to be 24" long minimum, centered on the water closet, where wall space does not permit a length of 36" minimum due to the location of a recessed fixture adjacent to the water closet. 2. Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall be permitted to be split or shifted to the open side of the toilet area.] The side wall grab bar shall be 42" long minimum, located 12" maximum from the rear wall and extending 54" minimum from the rear wall. Toilet paper dispensers shall be 7" minimum and 9" maximum in front of the water closet, measured to the centerline of the dispenser. The outlet of the dispenser shall be 15" minimum and 48" maximum above the finish floor and shall not be located behind grab bars. Where located below the side grab bar, the top of projecting toilet paper dispensers shall be located 1- 1/2" minimum below the grab bar. Where located above the side grab bar, the bottom of the projecting toilet paper dispenser shall be located 12" minimum above the top of the gripping surface of the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. [ADVISORY: It is advisable, but not required, to use the specifications for children where children are the primary users of the restroom. Guidance in applying the specifications for children according to the age group served reflects the differences in the size, stature, and reach ranges of children ages 3 to 12. The specifications chosen should correspond to the age of the primary user group. The specifications of one age group should be applied consistently in the installation of a water closet and related elements. Water Closet Centerline: Ages 3 and 4- 12"; Ages 5 through 8- 12" to 15"; Ages 9 through 12- 15" to 18". Toilet Seat Height: Ages 3 and 4- 11" to 12"; Ages 5 through 8- 12" to 15"; Ages 9 through 12- 15" to 17". Grab Bar Height: Ages 3 and 4- 18" to 20"; Ages 5 through 8- 20" to 25"; Ages 9 through 12- 25" to 27"; Dispenser Height: Ages 3 and 4- 14"; Ages 5 through 8- 14" to 17"; Ages 9 through 12- 17" to 19"]. Toilet compartment doors for wheelchair stalls, including door hardware, shall comply except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42" minimum. Doors shall be located in the front partition or in the side wall or partition farthest from the water closet. Where located in the front partition, the door opening shall be 4" maximum from the side wall or partition farthest from the water closet. Where located in the side wall or partition, the door opening shall be 4" maximum from the front partition. The wheelchair stall door shall be selfclosing. A compliant door pull shall be placed on both sides of the door near the latch. Toilet compartment doors shall not swing into the minimum required compartment area.Install door pulls near the latch on each side of wheelchair stall door. Handles, pulls, latches, locks, and other operable parts on doors and gates shall be compliant. Operable parts of such hardware shall be 34" minimum and 48" maximum above the finish floor or ground.
Priority 3
Quantity
1 EA
Unit Cost
3,437.50
Total Cost
$ 3,438
440 Submittal: November 1, 2024
Photos for Barrier ID: AX394114
441 Submittal: November 1, 2024
Barrier ID: AX394117
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Urinal
ADA Standard 605.4; 309
Barrier Detail
The flush control is located on the closed side and is more than 48" high, for an obstructed forward reach range of maximum 20" horizontally.
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
The urinal flush control is foot operated and is located on the floor at the wall behind the urinal.
Resolution
Remove and install a compliant flush control. Operable parts shall be placed within one or more of the allowable reach ranges
Priority 3
Quantity
1 EA
Unit Cost
391.25
Total Cost
$ 391
Photos for Barrier ID: AX394117
442 Submittal: November 1, 2024
Barrier ID: AX398694
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom-Lavatory
ADA Standard 213.3.4, 606.5
Barrier Detail Pipes are not insulated.
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The lavatory drainpipe and water supply lines are not insulated.
Resolution
Insulate water supply and drain pipes under the accessible lavatory. Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. Pipes under lavatories and sinks shall be free from sharp or abrasive surfaces. A minimum of one lavatory in a multi-lavatory restroom shall be a compliant lavatory.
Priority 3
Quantity
1 EA
Unit Cost
81.25 Total Cost
$ 81
Photos for Barrier ID: AX398694
443 Submittal: November 1, 2024
Barrier ID: AX394110
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom-Signage
ADA Standard ADA 703.4.2; CBC 216.2, 703.1, 703.2, 703.5 Barrier Detail
CALIFORNIA: The men's restroom does not have compliant signage at the door.
Location Description Men's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
A geometric sign is not provided on the door and a tactile sign is not provided on the latch side of the door.
Resolution
Install compliant signage. The men's restroom/bathing room geometric symbol shall be an equilateral triangle 1/4" thick, with edges 12" long and a vertex pointing upward. The triangle shall contrast with the door or doorway, either light on dark or dark on light. Each doorway leading to men's restrooms and bathing rooms shall have a geometric symbol mounted min. 58"-max. 60" above finish floor or ground, measured to the centerline of the symbol. Where a door is provided, the geometric symbol sign shall be located within 1" of the vertical centerline of the door. The edges of the geometric symbol signs shall be rounded, chafered, or eased. The corners of the geometric sign shall have minimum 1/8" radius. Compliant signage with the International Symbol of Accessibility (ISA) and tactile characters indicating men's shall be provided. The ISA shall be a white figure on a blue background. The blue shall be Color #15090 in Federal Standard 595B. [EXCEPTION: The enforcing agency may approve other colors of light-on-dark or dark-on-light contrast.] Signage with the International Symbol of Accessibility and Braille shall be located on the latch side of the doorway [EXCEPTION: Signs with tactile characters are permitted on the push sides of doors with closers and without hold-open devices]. Clear space of 18" minimum by 18" minimum shall be provided at the centerline of the tactile characters; the centerline of the tactile characters shall be minimum 9" distance outside of door swing. Tactile characters on signs shall be located 48" minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60" maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. Raised characters shall be complaint and shall be duplicated in Braille. Raised characters shall be as follows: Depth. Raised characters shall be 1/32" minimum above their background. Case - Characters shall be uppercase. Style- Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
Character Proportions - Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 % minimum and 110 % maximum of the height of the uppercase letter "I". Character Height- Character height measured vertically from the baseline of the character shall be 5/8" minimum and 2" maximum based on the height of the uppercase letter "I". [EXCEPTION: Where separate raised and visual characters with the same information are provided, raised character height shall be permitted to be 1/2" minimum.] The visual characters of the sign shall be installed at minimum 40" above finish floor.
Priority 3
Quantity
2 EA
Unit Cost
137.50
Total Cost
$ 275
444 Submittal: November 1, 2024
Photos for Barrier ID: AX394110
445 Submittal: November 1, 2024
Barrier ID: AX394109
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Reach Range
ADA Standard California Building Code Chap 11B-603.5
Barrier Detail CALIFORNIA: Dispensers in restrooms are not located maximum 40" AFF.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
The soap dispenser is 41" above the floor. The paper towel dispenser is 50" above the floor.
Resolution
Move the dispenser so that the outlet of the dispenser and all operable parts are maximum 40" above finish floor or existing grade. Where accessory dispensers, including towel dispensers, sanitary napkins, waste receptacles, or other accessories are provided, all operable parts and/or openings for the user including coin slots shall be maximum 40" above finish floor. [EXCEPTION: Does not apply to baby changing tables.] [ADVISORY: Where building elements such as coat hooks, lockers, or operable parts are designed for use primarily by children, the suggested dimensions for children shall be permitted. These dimensions apply to either forward or side reaches.
Suggested reach ranges for elements which are used primarily by children are as follows: Ages 3 to 4- low/minimum reach 20" and high/maximum reach 36"; Ages 5 through 8- low/minimum reach 18" and high/maximum reach 40"; Ages 9 through 12: low/minimum reach 16" and high/maximum reach 44".] Priority 3
Quantity
2 EA
Unit Cost
250.00
Total Cost
$ 500
446 Submittal: November 1, 2024
Photos for Barrier ID: AX394109
447 Submittal: November 1, 2024
Barrier ID: AX394122
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Reach Range
ADA Standard California Building Code Chap 11B-603.5
Barrier Detail CALIFORNIA: Dispensers in restrooms are not located maximum 40" AFF.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
The soap dispenser is 41" above the floor. The paper towel dispenser is 50" above the floor.
Resolution
Move the dispenser so that the outlet of the dispenser and all operable parts are maximum 40" above finish floor or existing grade. Where accessory dispensers, including towel dispensers, sanitary napkins, waste receptacles, or other accessories are provided, all operable parts and/or openings for the user including coin slots shall be maximum 40" above finish floor. [EXCEPTION: Does not apply to baby changing tables.] [ADVISORY: Where building elements such as coat hooks, lockers, or operable parts are designed for use primarily by children, the suggested dimensions for children shall be permitted. These dimensions apply to either forward or side reaches.
Suggested reach ranges for elements which are used primarily by children are as follows: Ages 3 to 4- low/minimum reach 20" and high/maximum reach 36"; Ages 5 through 8- low/minimum reach 18" and high/maximum reach 40"; Ages 9 through 12: low/minimum reach 16" and high/maximum reach 44".] Priority 3
Quantity
2 EA
Unit Cost
250.00
Total Cost
$ 500
448 Submittal: November 1, 2024
Photos for Barrier ID: AX394122
449 Submittal: November 1, 2024
Barrier ID: AX394104
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Coat Hook
ADA Standard 213.3.7, 604.8.3, 308
Barrier Detail The coat hook is not within an allowable reach range.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The coat hook is 57" above the floor.
Resolution
Install the coat hook within an allowable reach range. Unobstructed Forward Reach: Where a forward reach is unobstructed, the high forward reach shall be 48" maximum and the low forward reach shall be 15" minimum above the finish floor or ground. Obstructed High Forward Reach: Where a high forward reach is over an obstruction, the clear floor space shall extend beneath the element for a distance not less than the required reach depth over the obstruction. The high forward reach shall be 48" maximum where the reach depth is 20" maximum. Where the reach depth exceeds 20", the high forward reach shall be 44" maximum and the reach depth shall be 25" maximum. Unobstructed Side Reach: Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48" maximum and the low side reach shall be 15" minimum above the finish floor or ground. [EXCEPTION: An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10" maximum.] Obstructed High Side Reach: Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34" maximum and the depth of the obstruction shall be 24" maximum. The high side reach shall be 48" maximum for a reach depth of 10" maximum. Where the reach depth exceeds 10", the high side reach shall be 46" maximum for a reach depth of 24" maximum. [ADVISORY for Children's Forward or Side Reach Ranges: High reach (maximum): 36" for ages 3 to 4; 40" for ages 5 to 8; and 44" for ages 9 to 12. Low reach (minimum): 20" for ages 3 to 4; 18" for ages 5 to 8; and 16" for ages 9 to 12.]
Priority 3
Quantity
1 EA
Unit Cost
143.75
Total Cost
$ 144
450 Submittal: November 1, 2024
Photos for Barrier ID: AX394104
451 Submittal: November 1, 2024
Barrier ID: AX394098
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Door
ADA Standard 404.2; Table 404.2.4.1
Barrier Detail
The pull side of the accessible door does not have the required maneuvering clearances.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
For an approach from the latch side on the pull side the maneuvering depth is 53". The door has a closure.
Resolution
Redesign to provide the required maneuvering clearance at the pull side of the door. The required depth of the maneuvering clearance is 54" minimum. The required side clearance is 24" minimum on the latch/hinge side of the door. Maneuvering clearance shall extend the full width of the doorway and the required latch side or hinge side clearance. Floor or ground space within the required maneuvering clearance shall be maximum 1:48 (2.08%) slope. Changes in level are not permitted.
Priority 3
Quantity
1 EA
Unit Cost
1,562.50
Total Cost
$ 1,563
Photos for Barrier ID: AX394098
452 Submittal: November 1, 2024
Barrier ID: AX394100
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Door
ADA Standard 404.2.9
Barrier Detail
The force required to open the interior, hinged, non-fire door is more than 5 pounds.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The opening force is 15 pounds.
Resolution
Adjust closer or replace with an closer that requires no more 5 pounds of force to stop the door motion. This barrier must be removed in conjunction with barrier ID 394101. The cost of this barrier removal is covered under ID 394101 and therefore, the cost of this ID is shown as $0. The maximum force for pushing or pulling open a door shall be for interior hinged doors: 5 lbs (22.2N). The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum. These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door or gate in a closed position. Note: Fire doors shall have a minimum opening force allowable by the appropriate administrative authority.
Priority 3
Quantity
1 EA
Unit Cost
0.00 Total Cost
$ 0
Photos for Barrier ID: AX394100
453 Submittal: November 1, 2024
Barrier ID: AX394101
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Door
ADA Standard 404.2.8
Barrier Detail
The accessible door with door closer has a sweep period of less than 5 seconds from 90 degrees to a position 12 degrees from latch.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
The closing speed is 2.10 seconds from 90 degrees to a position 12 degrees from latch.
Resolution
Adjust closer or remove and replace closer to ensure that the door has a closure time of at least 5 seconds within 12 degrees of the latch. This barrier must be removed in conjunction with barrier ID 394100. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Priority 3
Quantity
1 EA
Unit Cost
457.50
Total Cost
$ 458
Photos for Barrier ID: AX394101
454 Submittal: November 1, 2024
Barrier ID: AX394105
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Lavatory
ADA Standard CBC Chap 11B-213, 306, 606
Barrier Detail
CALIFORNIA: The lavatory does not have the required knee and toe clearance.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The lavatory apron and knee clearance is 26-1/4" above the floor.
Resolution
Provide at least 10% but no fewer than one lavatory with compliant knee and toe clearance. The lavatory shall maintain the maximum allowable height of 34" to the rim of the sink. The maximum allowable exterior bowl depth is 6-1/2". A compliant clear floor space of minimum 30" wide centered on the lavatory and minimum 48" deep, positioned for a forward approach, shall be provided. Space under an element between 9" and 29" above the finish floor or ground shall be considered knee clearance and shall comply. Knee clearance shall be 11" deep minimum at 9" above the finish floor or ground, and 8" deep minimum at 27" above the finish floor. The bottom of the front of the lavatory shall be minimum 29" above the finish floor. Knee clearance reduction is not allowed. Toe clearance shall be minimum 25" horizontal depth between the finish floor and 9" AFF. Knee and toe clearance shall be 30" wide minimum and centered on the lavatory. A compliant clear floor space, positioned for a forward approach, and compliant knee and toe clearance shall be provided. [EXCEPTIONS: 1. Toe clearance shall extend 19" maximum under lavatories 2. A lavatory in a toilet room or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to provide knee and toe clearance. 3. In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the fixture; (b) the finish floor extends under the cabinetry; and (c) the walls behind and surrounding the cabinetry are finished. 4. A knee clearance of 24" minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31" maximum above the finish floor or ground. 5. A parallel approach complying with 305 shall be permitted to lavatories and sinks used primarily by children 5 years and younger.6. The dip of the overflow shall not be considered in determining knee and toe clearances. 7. No more than one bowl of a multi-bowl sink shall be required to provide knee and toe clearance.]
Priority 3
Quantity
1 EA
Unit Cost
900.00
Total Cost
$ 900
455 Submittal: November 1, 2024
Photos for Barrier ID: AX394105
456 Submittal: November 1, 2024
Barrier ID: AX394106
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Lavatory
ADA Standard 606.4; 309
Barrier Detail The lavatory faucet hardware is not compliant.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
The operable part of the lavatory faucet requires tight grasping and twisting of the wrist to operate.
Resolution
Provide push/lever hardware for the faucet. Replace faucet operating hardware with compliant handles.
Operable parts, such as faucet hardware, shall be operable with one hand and shall not require tight grasping, pinching, or twisting of the wrist. The force required to activate operable parts shall be 5 pounds (22.2 N) maximum. Hand-operated metering faucets shall remain open for 10 seconds minimum. Provide a minimum of one accessible sink with push/lever hardware.
Priority 3
Quantity
1 EA
Unit Cost
693.75
Total Cost
$ 694
Photos for Barrier ID: AX394106
457 Submittal: November 1, 2024
Barrier ID: AX394107
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Lavatory
ADA Standard 213.3.4, 606.5
Barrier Detail Pipes are not insulated.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The lavatory drainpipe and water supply lines are not insulated.
Resolution
Insulate water supply and drain pipes under the accessible lavatory. Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact. Pipes under lavatories and sinks shall be free from sharp or abrasive surfaces. A minimum of one lavatory in a multi-lavatory restroom shall be a compliant lavatory.
Priority 3
Quantity
1 EA
Unit Cost
81.25 Total Cost
$ 81
Photos for Barrier ID: AX394107
458 Submittal: November 1, 2024
Barrier ID: AX394108
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Mirror
ADA Standard 213.3.5; 603.3
Barrier Detail
The mirror is mounted higher than 40" above finish floor to the bottom of the reflective surface, where it is installed above a lavatory or counter.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The bottom of the reflective surface of the mirror is 41" above the floor.
Resolution
Remove and lower the mirror to a compliant height. Where mirrors are provided, at least one shall comply.
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40" maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35" maximum above the finish floor or ground. [ADVISORY: A single full-length mirror can accommodate a greater number of people, including children. In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74" minimum from the floor or ground.]
Priority 3
Quantity
1 EA
Unit Cost
250.00
Total Cost
$ 250
459 Submittal: November 1, 2024
Photos for Barrier ID: AX394108
460 Submittal: November 1, 2024
Barrier ID: AX394121
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Mirror
ADA Standard 213.3.5; 603.3
Barrier Detail
The mirror is mounted higher than 40" above finish floor to the bottom of the reflective surface, where it is installed above a lavatory or counter.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions The bottom of the reflective surface of the mirror is 41" above the floor.
Resolution
Remove and lower the mirror to a compliant height. Where mirrors are provided, at least one shall comply.
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40" maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35" maximum above the finish floor or ground. [ADVISORY: A single full-length mirror can accommodate a greater number of people, including children. In order for mirrors to be usable by people who are ambulatory and people who use wheelchairs, the top edge of mirrors should be 74" minimum from the floor or ground.]
Priority 3
Quantity
1 EA
Unit Cost
250.00
Total Cost
$ 250
461 Submittal: November 1, 2024
Photos for Barrier ID: AX394121
462 Submittal: November 1, 2024
Barrier ID: AX394102
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Signage
ADA Standard ADA 703.4.2; CBC 216.2, 703.1, 703.2, 703.5 Barrier Detail
CALIFORNIA: The women's restroom does not have compliant signage at the door.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions
A geometric sign is not provided on the door and a tactile sign is not provided on the latch side of the door.
Resolution
Install compliant signage at the restroom entrance. Women's toilet and bathing facilities shall be identified by a circle, ¼ inch thick and 12 inches in diameter. The circle symbol shall contrast with the door, either light on a dark background or dark on a light background. Each doorway leading to restrooms and bathing rooms shall have a geometric symbol mounted min. 58"-max. 60" above finish floor or ground, measured to the centerline of the symbol. Where a door is provided, the geometric symbol sign shall be located within 1" of the vertical centerline of the door. The edges of the geometric symbol signs shall be rounded, chafered, or eased. The corners of the geometric sign shall have minimum 1/8" radius. Compliant signage with the International Symbol of Accessibility (ISA) and tactile characters indicating women's shall be provided. The ISA shall be a white figure on a blue background. The blue shall be Color #15090 in Federal Standard 595B. [EXCEPTION: The enforcing agency may approve other colors of light-on-dark or dark-on-light contrast.] Signage with the International Symbol of Accessibility and Braille shall be located on the latch side of the doorway [EXCEPTION: SIgns with tactile characters are permitted on the push sides of doors with closers and without hold-open devices]. Clear space of 18" minimum by 18" minimum shall be provided at the centerline of the tactile characters; the centerline of the tactile characters shall be minimum 9" distance outside of door swing. Tactile characters on signs shall be located 48" minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60" maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. Raised characters shall be complaint and shall be duplicated in Braille. Raised characters shall be as follows: Depth. Raised characters shall be 1/32" minimum above their background. Case - Characters shall be uppercase. Style- Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms.
Character Proportions - Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 % minimum and 110 % maximum of the height of the uppercase letter "I". Character Height- Character height measured vertically from the baseline of the character shall be 5/8" minimum and 2" maximum based on the height of the uppercase letter "I". [EXCEPTION: Where separate raised and visual characters with the same information are provided, raised character height shall be permitted to be 1/2" minimum.] The visual characters of the sign shall be installed at minimum 40" above finish floor.
Priority 3
Quantity
1 EA
Unit Cost
137.50
Total Cost
$ 138
463 Submittal: November 1, 2024
Photos for Barrier ID: AX394102
464 Submittal: November 1, 2024
Barrier ID: AX394103
City of Industry Council Chambers INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Toilet Stall
ADA Standard
309, 404.2.7, 604.5.1, 604.6, 604.7, 604.8.1.1, 604.8.1.2, 604.8.1.5, 604.9, 609.3 Barrier Detail A wheelchair stall is not provided in a multi-user restroom.
Location Description Women's Restroom
Observed Sep 27, 2023 by [email protected] Site Conditions A wheelchair stall is not provided in the multi-user restroom. 465 Submittal: November 1, 2024
Resolution
Provide a compliant wheelchair stall with compliant elements in the multi-user restroom. Wheelchair accessible compartments with floor mounted water closets shall be 60" wide minimum measured perpendicular to the side wall and 59" deep minimum, measured perpendicular to the rear wall. Wheelchair accessible compartments with wall mounted water closets shall be 60" wide minimum measured perpendicular to the side wall and 56" deep minimum, measured perpendicular to the rear wall. Wheelchair accessible compartments for children's use (ages 3 through 12) shall be 60" wide minimum measured perpendicular to the side wall, and 59" deep minimum for wall hung and floor mounted water closets measured perpendicular to the rear wall.In addition, clear space of minimum 30" by 48" must be provided within the clearance area for transfer from a wheelchair. The water closet shall be positioned with a wall or partition to the rear and to one side. The centerline of the water closet shall be 16 minimum to 18" maximum from the side wall or partition. Water closets shall be arranged for a left-hand or right-hand approach. The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space. No other fixtures or obstructions, such as lavatories, shall be located within the required water closet clearance. Install a flush control on the open side of the water closet. Flush controls shall be hand operated or automatic. Hand operated flush controls shall be within a compliant reach range. Install compliant grab bars. Horizontal grab bars shall be installed at a consistent height above finish floor to the top of the gripping surface. The top of the gripping surface shall be minimum 33" and maximum 36" above finish floor. The rear wall grab bar shall be 36" long minimum and extend from the centerline of the water closet 12" minimum on one side and 24" minimum on the other side. [EXCEPTIONS: 1. The rear grab bar shall be permitted to be 24" long minimum, centered on the water closet, where wall space does not permit a length of 36" minimum due to the location of a recessed fixture adjacent to the water closet. 2. Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall be permitted to be split or shifted to the open side of the toilet area.] The side wall grab bar shall be 42" long minimum, located 12" maximum from the rear wall and extending 54" minimum from the rear wall. Toilet paper dispensers shall be 7" minimum and 9" maximum in front of the water closet, measured to the centerline of the dispenser. The outlet of the dispenser shall be 15" minimum and 48" maximum above the finish floor and shall not be located behind grab bars. Where located below the side grab bar, the top of projecting toilet paper dispensers shall be located 1- 1/2" minimum below the grab bar. Where located above the side grab bar, the bottom of the projecting toilet paper dispenser shall be located 12" minimum above the top of the gripping surface of the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. [ADVISORY: It is advisable, but not required, to use the specifications for children where children are the primary users of the restroom. Guidance in applying the specifications for children according to the age group served reflects the differences in the size, stature, and reach ranges of children ages 3 to 12. The specifications chosen should correspond to the age of the primary user group. The specifications of one age group should be applied consistently in the installation of a water closet and related elements. Water Closet Centerline: Ages 3 and 4- 12"; Ages 5 through 8- 12" to 15"; Ages 9 through 12- 15" to 18". Toilet Seat Height: Ages 3 and 4- 11" to 12"; Ages 5 through 8- 12" to 15"; Ages 9 through 12- 15" to 17". Grab Bar Height: Ages 3 and 4- 18" to 20"; Ages 5 through 8- 20" to 25"; Ages 9 through 12- 25" to 27"; Dispenser Height: Ages 3 and 4- 14"; Ages 5 through 8- 14" to 17"; Ages 9 through 12- 17" to 19"]. Toilet compartment doors for wheelchair stalls, including door hardware, shall comply except that if the approach is to the latch side of the compartment door, clearance between the door side of the compartment and any obstruction shall be 42" minimum. Doors shall be located in the front partition or in the side wall or partition farthest from the water closet. Where located in the front partition, the door opening shall be 4" maximum from the side wall or partition farthest from the water closet. Where located in the side wall or partition, the door opening shall be 4" maximum from the front partition. The wheelchair stall door shall be selfclosing. A compliant door pull shall be placed on both sides of the door near the latch. Toilet compartment doors shall not swing into the minimum required compartment area.Install door pulls near the latch on each side of wheelchair stall door. Handles, pulls, latches, locks, and other operable parts on doors and gates shall be compliant. Operable parts of such hardware shall be 34" minimum and 48" maximum above the finish floor or ground.
Priority 3
Quantity
1 EA
Unit Cost
3,437.50
Total Cost
$ 3,438
466 Submittal: November 1, 2024
Photos for Barrier ID: AX394103
467 Submittal: November 1, 2024
Barrier ID: AX394083
City of Industry Council Chambers INTERIOR
Assembly Exterior Access Route
Type Signage
ADA Standard 216.2, 703.1, 703.2, 703.5
Barrier Detail Signage identifying a permanent indoor space is not provided.
Location Description Council Chambers Entry
Observed Sep 27, 2023 by [email protected] Site Conditions A tactile sign is not provided on the latch side of the door.
Resolution
Provide signage with print of compliant character height and provide raised lettering. Raised lettering shall comply with 703.2 and include Braille. Visual characters shall comply with 703.5. The minimum character height shall be 5/8" when the horizontal viewing distance is less than 72" and the signage height to baseline of the character from ground is from 40" to 70". Where the baseline of the characters is located between 70" and 120" from the ground, and the horizontal viewing distance less than 180", the min. character height is 2".
Priority 4
Quantity
2 EA
Unit Cost
116.25
Total Cost
$ 233
468 Submittal: November 1, 2024
Photos for Barrier ID: AX394083
469 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
CULTURAL HOMESTEAD MUSEUM
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
470 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Site Plan:
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
471 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Floor Plan:
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
472 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
FACILITY: CULTURAL HOMESTEAD MUSEUM
Facility Description:
Facility was constructed in the year .
Facility Address:
This facility is used for the following programs:
1919
Historic Building Tours
Private and Public Events
15415 Don Julian Rd.
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
473 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-01
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.1
The provided access aisle width is less than the minimum 60 inches.
Recommended Remediation:
Reconfigure spaces by repainting lines. Dimensions to be measured to centerline. Keep access aisle out of the gutter to maintain maximum 2% cross slope. (See site plan for locations) Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 56 inches
502.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Width
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950 Comment #: CHM-02
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.6 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
474 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-03
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950 Comment #: CHM-04
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Raise signs so that the bottom of the sign is higher than 60 inches above the ground.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Identification Signs
Measurement: 3 count
502.6 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
475 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-34
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-403.3
The running slope, parallel to the path of travel, exceeds the allowable 5% grade.
Recommended Remediation:
Remove and dispose of noncompliant route materials and
replace and re-grade so that the running slope does not exceed 5%.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $240
Site Elements Exterior Access Route
Slope
Measurement: 12.1 % grade
402.2/403.3 Quantity: 16 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.7 Running Slope
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $312 Route
Comment #: CHM-35
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 5 Estimated Direct Cost: $1,800
Site Elements Exterior Access Route
Curb Ramp
Measurement: 5 count
N/A Quantity: 5 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:D
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $2,340 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
476 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-36
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.2.1
The running slope of the curb ramp exceeds the allowable 8.33% maximum grade.
Recommended Remediation:
Remove and dispose of materials and replace and re-grade to provide an accessible curb ramp. Drop the entire path to eliminate excessive running slope.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $4,500
Site Elements Exterior Access Route
Curb Ramp
Measurement: 15.8 % grade
405.2 Quantity: 300 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Running Slope
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $5,850 Route
Comment #: CHM-05
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.1
The provided access aisle width is less than the minimum 60 inches.
Recommended Remediation:
Reconfigure spaces by repainting lines. Dimensions to be measured to centerline. Keep access aisle out of the gutter to maintain maximum 2% cross slope.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 56 inches
502.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Width
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
477 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-06
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA symbol has deteriorated and no longer provides contrast with the ground surface.
Recommended Remediation:
Repaint the ISA. Striping shall be maintained per CBC 11B-108 and ADA CFR 25.133. Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Parking
ISA Marking
Measurement: 3 count
502.3.3 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,560 Comment #: CHM-07
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
478 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-08
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950 Comment #: CHM-09
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Raise signs so that the bottom of the sign is higher than 60 inches above the ground.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Identification Signs
Measurement: 3 count
502.6 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
479 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-10
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.1
The provided access aisle width is less than the minimum 60 inches.
Recommended Remediation:
Reconfigure spaces by repainting lines. Dimensions to be measured to centerline. Keep access aisle out of the gutter to maintain maximum 2% cross slope.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 56 inches
502.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Width
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950 Comment #: CHM-11
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
480 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-12
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Raise signs so that the bottom of the sign is higher than 60 inches above the ground.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Identification Signs
Measurement: 3 count
502.6 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950 Comment #: CHM-13
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
481 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-14
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA symbol has deteriorated and no longer provides contrast with the ground surface.
Recommended Remediation:
Repaint the ISA. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Parking
ISA Marking
Measurement: 3 count
502.3.3 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,560 Comment #: CHM-37
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 5 Estimated Direct Cost: $1,800
Site Elements Exterior Access Route
Curb Ramp
Measurement: 5 count
N/A Quantity: 5 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:D
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $2,340 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
482 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-15
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.1
The provided access aisle width is less than the minimum 60 inches.
Recommended Remediation:
Reconfigure spaces by repainting lines. Dimensions to be measured to centerline. Keep access aisle out of the gutter to maintain maximum 2% cross slope.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 56 inches
502.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Width
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $975 Comment #: CHM-16
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
483 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-17
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950 Comment #: CHM-18
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Raise signs so that the bottom of the sign is higher than 60 inches above the ground.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Identification Signs
Measurement: 3 count
502.6 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
484 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-19
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA symbol has deteriorated and no longer provides contrast with the ground surface.
Recommended Remediation:
Repaint the ISA. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Parking
ISA Marking
Measurement: 3 count
502.3.3 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,560 Comment #: CHM-38
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-303.2
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $720
Site Elements Exterior Access Route
Surface Continuity
Measurement: .75 inches
303.2/303.3 Quantity: 8 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $936 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
485 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-20
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.1
The provided access aisle width is less than the minimum 60 inches when measured to the centerlines of the blue border lines.
Recommended Remediation:
Reconfigure spaces by repainting lines. Dimensions to be measured to centerline. Keep access aisle out of the gutter to maintain maximum 2% cross slope.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 56 inches
502.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Width
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $975 Comment #: CHM-21
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
486 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-22
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950 Comment #: CHM-23
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Raise signs so that the bottom of the sign is higher than 60 inches above the ground.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Identification Signs
Measurement: 3 count
502.6 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
487 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-24
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA symbol has deteriorated and no longer provides contrast with the ground surface.
Recommended Remediation:
Repaint the ISA. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Parking
ISA Marking
Measurement: 3 count
502.3.3 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,560 Comment #: CHM-39
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 5 Estimated Direct Cost: $1,800
Site Elements Exterior Access Route
Curb Ramp
Measurement: 5 count
N/A Quantity: 5 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:D
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $2,340 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
488 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-40
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-303.2
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Surface Continuity
Measurement: 1.75 inches
303.2/303.3 Quantity: 4 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $468 Route
Comment #: CHM-25
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.1
The provided access aisle width is less than the minimum 60 inches.
Recommended Remediation:
Reconfigure spaces by repainting lines. Dimensions to be measured to centerline. Keep access aisle out of the gutter to maintain maximum 2% cross slope.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 56 inches
502.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Width
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
489 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-26
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950 Comment #: CHM-27
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
490 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-28
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Raise signs so that the bottom of the sign is higher than 60 inches above the ground.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Identification Signs
Measurement: 3 count
502.6 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,950 Comment #: CHM-29
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA symbol has deteriorated and no longer provides contrast with the ground surface.
Recommended Remediation:
Repaint the ISA. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Parking
ISA Marking
Measurement: 3 count
502.3.3 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,560
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
491 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-30
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.7
There is no path of travel from the accessible parking to the facility entrance.
Recommended Remediation:
A) Remove the features designating this as an accessible stall.
There are already 18 additional Accessible parking spaces which is more than minimum requirement.
B) Or, Relocate so that the provided stall is connected to an accessible route.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Path of Travel
Measurement: 1 count
206.2.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $975 Comment #: CHM-31
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-208.2.4
One access space in every six access spaces (or portion of 6) is not van accessible.
Recommended Remediation:
Reconfigure spaces by repainting lines. Include signage indicating van accessible spaces. With 18 Accessible spaces, minimum 3 van accessible Spaces are required. Verify if this met the old code, this is only required to be updated when restriped.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $2,250
Site Elements Parking
Van Accessibility
Measurement: 0 count
208.2 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Count
Severity:C
Category Parking Precedence 7 Year 3 Cost with GC (30%): $2,925
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
492 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-41
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.2.1
The running slope of the curb ramp exceeds the allowable 8.33% maximum grade.
Recommended Remediation:
Remove and dispose of materials and replace and re-grade to provide an accessible curb ramp. Include detectable warning surface and flush transitions.
Floor/Area: Satellite Parking
Room/Spot: Path of Travel
Priority: 1 Estimated Direct Cost: $1,875
Site Elements Exterior Access Route
Curb Ramp
Measurement: 13.6 % grade
405.2 Quantity: 125 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Running Slope
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $2,438 Route
Comment #: CHM-32
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.8
There is no tow away sign provided at the entrance to the parking lot.
Recommended Remediation:
Install a Caltrans R-100B sign at the entrance to the parking lot.
Needed when gate is open at both entrances to the satellite lot. Floor/Area: Satellite Parking Room/Spot: Lot Entrance
Priority: 5 Estimated Direct Cost: $1,000
Site Elements Parking
Tow Away Signage
Measurement: 1 count
208.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:D
Category Parking Precedence 7 Year 3 Cost with GC (30%): $1,300
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
493 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-42
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.3.2
There is no level landing provided at the base of the parallel curb ramp with a slope no greater than the allowable 2.0% grade.
Recommended Remediation:
Remove and replace the parallel curb ramp including detectable warning surface and flush transitions. Floor/Area: Satellite Parking Room/Spot: Lot Entrance
Priority: 1 Estimated Direct Cost: $1,875
Site Elements Exterior Access Route
Curb Ramp
Measurement: 2.5 % grade
405.7.1 Quantity: 125 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Landing: Cross Slope
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $2,438 Route
Comment #: CHM-43
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.2.1
The running slope of the curb ramp exceeds the allowable 8.33% maximum grade.
Recommended Remediation:
Remove and dispose of materials and replace and re-grade to provide an accessible curb ramp. Include detectable warning surface and flush transitions.
Floor/Area: Lot Entrance
Room/Spot: Path of Travel
Priority: 1 Estimated Direct Cost: $1,875
Site Elements Exterior Access Route
Curb Ramp
Measurement: 15.1 % grade
405.2 Quantity: 125 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Running Slope
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $2,438 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
494 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-44
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking Adjacent
Room/Spot: Path of Travel
Priority: 1 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $468 Route
Comment #: CHM-45
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking Adjacent
Room/Spot: Path of Travel
Priority: 1 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $468 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
495 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-46
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking Adjacent
Room/Spot: Path of Travel
Priority: 1 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $468 Route
Comment #: CHM-47
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking Adjacent
Room/Spot: Path of Travel
Priority: 1 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $468 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
496 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-48
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-216.3
No signage exists identifying the accessible exterior access route nor at junctions along the route that direct pedestrians to the accessible entrance of the facility.
Recommended Remediation:
Provide directional signage at junctions along the accessible route that direct pedestrians to the accessible entrance. There are no curb ramps connecting the route. Install directional signage at path divergences.
Floor/Area: Parking Adjacent
Room/Spot: Path of Travel
Priority: 1 Estimated Direct Cost: $2,883
Site Elements Exterior Access Route
Curb Ramp
Measurement: 3 count
216.6 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3 (16B)
Directional Signage
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $3,748 Route
Comment #: CHM-49
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-303.5
An abrupt drop-off exists that is greater than 4 inches in the concrete walkway and is not protected by a warning curb.
Recommended Remediation:
Install a warning curb between the pathway and the abrupt dropoff. Floor/Area: Path of Travel Room/Spot: Pond
Priority: 1 Estimated Direct Cost: $0
Site Elements Exterior Access Route
Drop-off
Measurement: 6 inches
N/A Quantity: 550 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Warning Curb
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $0 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
497 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-50
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-402.2
The running slope, parallel to the path of travel, exceeds the allowable 5% grade.
Recommended Remediation:
Remove and dispose of noncompliant route materials and
replace and re-grade to create a ramp. Add ramp features such as compliant landings and handrails.
Floor/Area: Exterior Access Route
Room/Spot: Pond Adjacent
Priority: 1 Estimated Direct Cost: $4,500
Site Elements Exterior Access Route
Slope
Measurement: 13.4 % grade
402.2/403.3 Quantity: 300 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.7 Running Slope
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $5,850 Route
Comment #: CHM-51
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-307.2
Tree branches along all walkways in the cemetery overhang the pedestrian pathway and obstruct the clear 80 inches of required vertical clearance.
Recommended Remediation:
Trim the tree branches so that a vertical clearance of minimum 80 inches is maintained along all pedestrian pathways. Floor/Area: Cemetery Room/Spot: Pathways
Priority: 1 Estimated Direct Cost: $810
Site Elements Exterior Access Route
Protrusion
Measurement: 42 inches
N/A Quantity: 9 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $1,053 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
498 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-52
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-210.1
There is no accessible route to view the interior of the mausoleum.
Recommended Remediation:
Provide an information sign that includes pictures of the mausoleum interior for those who cannot climb the stairs or add a lift for accessible access.
Floor/Area: Cemetery
Room/Spot: Mausoleum
Priority: 1 Estimated Direct Cost: $0
Site Elements Exterior Access Route
General Access
Measurement: 1 count
504 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Stairs
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $0 Route
Comment #: CHM-53
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-403.3
The cross slope, perpendicular to the path of travel, exceeds the allowable 2.0% grade.
Recommended Remediation:
Remove and dispose of noncompliant route materials and
replace and re-grade so that the cross slope does not exceed
2.0%. The driveway must be removed and replaced to maintain POT as well.
Floor/Area: Parking
Room/Spot: Lot Entrance Adjacent
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Exterior Access Route
Slope
Measurement: 2.8 % grade
405.2 Quantity: 80 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Cross Slope
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $1,560 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
499 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-33
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-502.8
There is no tow away sign provided at the entrance to the parking lot.
Recommended Remediation:
Install a Caltrans R-100B sign at the entrance to the parking lot.
Floor/Area: Parking
Room/Spot: Main Entrance
Priority: 5 Estimated Direct Cost: $500
Site Elements Parking
Tow Away Signage
Measurement: 1 count
208.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:D
Category Parking Precedence 7 Year 3 Cost with GC (30%): $650 Comment #: CHM-54
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-402.2
The running slope, parallel to the path of travel, exceeds the allowable 5% grade.
Recommended Remediation:
Add ramp features such as edge protection, landings, and handrails. Floor/Area: Museum
Room/Spot: Picnic area path
Priority: 1 Estimated Direct Cost: $28,080
Site Elements Exterior Access Route
Slope
Measurement: 5.8 % grade
402.2/403.3 Quantity: 72 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.7 Running Slope
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $36,504 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
500 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-71
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-902.2
A minimum of 5% (with at least 1) of the total seating and standing space is not accessible for use of people in
wheelchairs.
Recommended Remediation:
Need minimum 4 wheel chair seating spaces. 2 currently exist so you must modify 1 table. At the wheelchair seating spaces level the decomposed granite. Make sure one of the trash cans is adjacent to the leveled area.
Floor/Area: Museum
Room/Spot: Panic Area
Priority: 2 Estimated Direct Cost: $2,600
Goods and Services Seating
Dining and Work
Surfaces
Measurement: 62 count
402.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.7 General Accessibility
Severity:C
Category Seating Precedence 8 Year 3 Cost with GC (30%): $3,380 Comment #: CHM-55
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-403.3
The cross slope, perpendicular to the path of travel, exceeds the allowable 2.0% grade, possibly due to the roots of the adjacent tree.
Recommended Remediation:
Remove and dispose of noncompliant route materials, cut back tree roots, and replace and re-grade so that the cross slope does not exceed 2.0%.
Floor/Area: Museum
Room/Spot: Picnic Area path
Priority: 1 Estimated Direct Cost: $4,050
Site Elements Exterior Access Route
Slope
Measurement: 2.9 % grade
402.2/403.3 Quantity: 270 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.7 Cross Slope
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $5,265 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
501 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-56
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-303.2
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Museum
Room/Spot: Picnic area path
Priority: 1 Estimated Direct Cost: $450
Site Elements Exterior Access Route
Surface Continuity
Measurement: .5 inches
303.2/303.3 Quantity: 5 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $585 Route
Comment #: CHM-57
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-303.2, 2016 CBC 11B-402.2
There exists a vertical displacement greater than 0.5 inches.
Additionally, the running slope, parallel to the path of travel, exceeds the allowable 5% grade at 8.8%.
Recommended Remediation:
Replace the floor boards and remove the doorway threshold.
Insure that the new floorboards slope less than 5% grade. Floor/Area: Museum Room/Spot: Workmen House
Priority: 2 Estimated Direct Cost: $4,500
Site Elements Exterior Access Route
Surface Continuity
Measurement: .75 inches
303.2/303.3 Quantity: 50 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $5,850 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
502 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-58
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-504.4.1
Warning stripes are not provided on every step of an exterior staircase.
Recommended Remediation:
Add contrasting stripes between 2 and 4 inches wide across the entire width of each tread and the upper approach. Only the top landing requires a stripe. Top landing.
Floor/Area: Museum
Room/Spot: Workmen House
Priority: 5 Estimated Direct Cost: $90
Site Elements Exterior Access Route
Stairs
Measurement: 8 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Warning Stripes
Severity:D
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $117 Route
Comment #: CHM-66
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-404.2.5
Threshold is more than the allowable 1/2 inch high.
Recommended Remediation:
Adjust the grades at the exterior side and remove and replace the threshold. Floor/Area: Museum
Room/Spot: La Casa Nueva
Priority: 2 Estimated Direct Cost: $90
Entrance Doors, Doorways,
Threshold Gates
Measurement: 3.25 inches
303.2/303.3/404.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.8 Height
Severity:A
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $117 Gates
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
503 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-67
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-404.2.5
Threshold is more than the allowable 1/2 inch high.
Recommended Remediation:
Raise door landing to meet same elevation as opposite side of door. Floor/Area: Museum
Room/Spot: La Casa Nueva
Priority: 2 Estimated Direct Cost: $3,600
Entrance Doors, Doorways,
Threshold Gates
Measurement: 2.5 inches
303.2/303.3/404.2 Quantity: 40 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.8 Height
Severity:A
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $4,680 Gates
Comment #: CHM-59
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-402.2
There is no accessible path of travel to the upper floor of the La Casa Nueva building.
Recommended Remediation:
Due to the historic status of the building videos and pictures need to be provided until this item is completed. Additional research is required.
Floor/Area: Museum
Room/Spot: La Casa Nueva
Priority: 1 Estimated Direct Cost: $90
Site Elements Exterior Access Route
Stairs
Measurement: 1 count
504 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $117 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
504 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-60
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-504.4.1, 2016 CBC 11B-505.4
The stairs do not provide compliant handrails nor do the provide warning stripes.
Recommended Remediation:
Recommend warning stripes and rod iron rails that match the historical character. 12 linear feet for the handrails. this needs to be coordinated with the City of Industry's Historical Department.
Floor/Area: Museum
Room/Spot: La Casa Nueva
Priority: 1 Estimated Direct Cost: $120,000
Site Elements Exterior Access Route
Stairs
Measurement: 1 count
505.2 Quantity: 12 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Handrails
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $156,000 Route
Comment #: CHM-68
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-216.3
Not all entrances to each building is accessible.
Recommended Remediation:
Assign accessible entrances with signs and directional signs.
ISA at Accessible entrances to each building. Approximately 15 signs.
Floor/Area: Museum
Room/Spot: La Casa Nueva
Priority: 1 Estimated Direct Cost: $14,415
Site Elements Entrance
Identification
Measurement: 1 count
216.6 Quantity: 15 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16B)
ISA Sign
Severity:C
Category Entrance Precedence 7 Year 3 Cost with GC (30%): $18,740
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
505 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-69
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-404.2.5
Threshold is more than the allowable 1/2 inch high.
Recommended Remediation:
Remove or replace threshold.
Floor/Area: Museum
Room/Spot: Museum Store
Priority: 2 Estimated Direct Cost: $90
Entrance Doors, Doorways,
Threshold Gates
Measurement: 1 inches
303.2/303.3/404.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.8 Height
Severity:A
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $117 Gates
Comment #: CHM-61
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-402.2
The running slope, parallel to the path of travel, exceeds the allowable 5% grade.
Recommended Remediation:
Remove and dispose of noncompliant route materials and
replace and re-grade so that the running slope does not exceed 5%. Need to remove and regrade the path around the entrance to La Casa Nueva.
Floor/Area: Museum
Room/Spot: Grounds Near Gazebo
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Exterior Access Route
Slope
Measurement: 13.6 % grade
402.2/403.3 Quantity: 100 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.7 Running Slope
Severity:B
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $1,950 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
506 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-62
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-303.2
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Compress and pack decomposed granite so that the walkway transitions are flush. Approximately 12,000 sq ft. The drain placement near the concrete paths make it difficult to maintain decomposed granite. Maintain a 1:48 slope maximum in any direction.
Floor/Area: Museum
Room/Spot: All Grounds
Priority: 1 Estimated Direct Cost: $36,000
Site Elements Exterior Access Route
Surface Continuity
Measurement: 1.5 inches
303.2/303.3 Quantity: ? sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $46,800 Route
Comment #: CHM-63
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-307.2
Tree branches overhang the pedestrian pathway and obstruct the clear 80 inches of required vertical clearance.
Recommended Remediation:
Trim the tree branches so that a vertical clearance of minimum 80 inches is maintained along all pedestrian pathways. Floor/Area: Museum Room/Spot: All Grounds
Priority: 1 Estimated Direct Cost: $900
Site Elements Exterior Access Route
Protrusion
Measurement: 64 inches
N/A Quantity: 10 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $1,170 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
507 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-64
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-505.10.1
The stairs do not provide compliant handrails with extensions that provide a safe return.
Recommended Remediation:
Provide a safe return for the handrail extensions. Include warning stripes for the adjacent stairs at the east entrance. No image available for the stairs because of workers.
Floor/Area: Museum
Room/Spot: Workman House Ramp
Priority: 1 Estimated Direct Cost: $0
Site Elements Exterior Access Route
Ramps
Measurement: 1.5 inches
405.8/505 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Safe Return
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $0 Route
Comment #: CHM-70
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-213.2
The available space provided for the restrooms is not adequate clearance space. Additional features are noncompliant including lack of accessible stalls and hi/lo drinking fountains.
Recommended Remediation:
The entire restroom needs to be demolished and an accessible restroom needs to be engineered in its place. A) Recommend making both restrooms gender neutral. B) Reconfigure 1 restroom to be accessible. C) Provide signage at non-accessible restroom directing to accessible restroom. D) Provide ISA on accessible restroom.
Floor/Area: Museum
Room/Spot: Homestead Museum
Gallery
Priority: 2 Estimated Direct Cost: $5,000
Public Toilet Rooms General Accessibility
Clearance Space
Measurement: 1 count
603.2.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.2.3 General
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $6,500 Accessibility
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
508 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: CHM-65
Facility: Cultural Homestead
Museum
Deficiency:
Code References:
2016 CBC 11B-303.2
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Path of Travel
Room/Spot: Adjacent to Parking Lot
Priority: 1 Estimated Direct Cost: $900
Site Elements Exterior Access Route
Surface Continuity
Measurement: .75 inches
303.2/303.3 Quantity: 10 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 7 Year 3 Cost with GC (30%): $1,170 Route
CULTURAL HOMESTEAD MUSEUM PAGE FACILITIES
509 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
EL ENCANTO HOSPITAL
EL ENCANTO HOSPITAL PAGE FACILITIES
510 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Site Plan:
EL ENCANTO HOSPITAL PAGE FACILITIES
511 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Floor Plan:
EL ENCANTO HOSPITAL PAGE FACILITIES
512 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
FACILITY: EL ENCANTO HOSPITAL
Facility Description:
Facility was constructed in the year .
Facility Address:
This facility is used for the following programs:
555 El
Encanto
Skilled nursing facilities offering a wide variety of healthcare and nursing services including comprehensive subacute and skilled nursing care, as well as long term residential care.
1963
EL ENCANTO HOSPITAL PAGE FACILITIES
513 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-01
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.8.2
The verbiage on the "tow-away" sign is not compliant with 2016 CBC 11B-502.8.2.
Recommended Remediation:
Remove and replace the current sign with a Caltrans R-100B sign, and provide reclaim vehicle information as a permanent part of the sign. An additional sign shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible from each parking space.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 5 Estimated Direct Cost: $500
Site Elements Parking
Tow Away Signage
Measurement: 1 count
208.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Verbiage
Severity:D
Category Parking Precedence 4 Year 1 Cost with GC (30%): $650 Comment #: EEH-20
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-216.3
This path from the accessible parking area is not part of the accessible route.
Recommended Remediation:
Chain this off and put a directional sign with ISA pointing towards accessible cross walk and ramp to facility Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $961
Site Elements Exterior Access Route
Signage
Measurement: 1 count
216.6 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3 (16B)
Directional Signage
Severity:C
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $1,249 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
514 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-02
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.3.1
The provided access aisle width is less than the minimum 60 inches.
Recommended Remediation:
Reconfigure spaces by repainting lines. Dimensions to be measured to centerline. Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 56 inches
502.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Width
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $975 Comment #: EEH-03
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 1 count
502.3.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $975
EL ENCANTO HOSPITAL PAGE FACILITIES
515 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-04
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Raise signs so that the bottom of the sign is higher than 60 inches above the ground. Include post mounted signs with ‘Minimum Fine’ and designated Van Accessible stalls.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,000
Site Elements Parking
Identification Signs
Measurement: 2 count
502.6 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $1,300 Comment #: EEH-05
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface..
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $350
Site Elements Parking
Access Aisles
Measurement: 1 count
502.3.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $455
EL ENCANTO HOSPITAL PAGE FACILITIES
516 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-21
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.2.1
The running slope of the curb ramp exceeds the allowable 1:12 (8.33%) grade. Additional ramp features are noncompliant.
Recommended Remediation:
Remove and dispose of materials and replace and re-grade to provide an accessible curb ramp. Include detectable warning surface.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Exterior Access Route
Curb Ramp
Measurement: 11 % grade
405.2 Quantity: 80 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Running Slope
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $1,560 Route
Comment #: EEH-06
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA symbol has deteriorated and no longer provides contrast with the ground surface.
Recommended Remediation:
Repaint the ISA. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $800
Site Elements Parking
ISA Marking
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $1,040
EL ENCANTO HOSPITAL PAGE FACILITIES
517 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-07
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.3.1
The provided access aisle width is less than the minimum 60 inches.
Recommended Remediation:
Reconfigure spaces by repainting lines. Dimensions to be measured to centerline. Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 56 inches
502.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Width
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $975 Comment #: EEH-08
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 1 count
502.3.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $975
EL ENCANTO HOSPITAL PAGE FACILITIES
518 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-09
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Raise signs so that the bottom of the sign is higher than 60 inches above the ground. Include post mounted signs with ‘Minimum Fine’ and designated Van Accessible stalls.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,000
Site Elements Parking
Identification Signs
Measurement: 2 count
502.6 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $1,300 Comment #: EEH-10
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 1 count
502.3.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $975
EL ENCANTO HOSPITAL PAGE FACILITIES
519 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-11
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-504.2
The slope of the accessible parking spaces and aisles are steeper than the allowable 2.0%
Recommended Remediation:
Re-grade accessible surfaces so that the slope does not exceed
2.0%. This applies to the southern most stall and access aisle on the southern set of accessible parking spaces.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,000
Site Elements Parking
Accessible Stall
Measurement: 2.8 % grade
502.4 Quantity: 306 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Slope
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $1,300 Comment #: EEH-12
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA symbol has deteriorated and no longer provides contrast with the ground surface.
Recommended Remediation:
Repaint the ISA. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $800
Site Elements Parking
ISA Marking
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $1,040
EL ENCANTO HOSPITAL PAGE FACILITIES
520 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-22
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.3.2
There is no level landing provided at the base of the parallel curb ramp with a slope no greater than the allowable 2.0% grade.
Recommended Remediation:
Remove and replace the parallel curb ramp including detectable warning surface and flush transitions. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Exterior Access Route
Curb Ramp
Measurement: 4.6 % grade
405.7.1 Quantity: 80 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Landing: Cross Slope
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $1,560 Route
Comment #: EEH-23
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-303.2
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Surface Continuity
Measurement: .75 inches
303.2/303.3 Quantity: 4 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $468 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
521 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-24
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 5 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:D
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $468 Route
Comment #: EEH-25
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-402.2
Where the accessible route crosses the curb no compliant curb ramp is provided.
Recommended Remediation:
Install a curb ramp with compliant detectable warning surface directly across from accessible parking ramp. Include striped cross walk, or provide directional signage to nearby curb ramp.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $5,270
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
406.6 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Accessible Route
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $6,851 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
522 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-13
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Raise signs so that the bottom of the sign is higher than 60 inches above the ground. Include post mounted signs with ‘Minimum Fine’ and designated Van Accessible stalls.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Parking
Identification Signs
Measurement: 6 count
502.6 Quantity: 6 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $3,900 Comment #: EEH-14
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.2
The Accessible Van Stall is less than 144 inches wide and the adjacent access aisle is less than 96 inches wide.
Recommended Remediation:
Reconfigure spaces by repainting lines. Dimensions to be measured to centerline. Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $2,250
Site Elements Parking
Access Aisles
Measurement: 93 inches
502.2 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Van Width
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $2,925
EL ENCANTO HOSPITAL PAGE FACILITIES
523 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-15
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $2,250
Site Elements Parking
Access Aisles
Measurement: 3 count
502.3.3 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $2,925 Comment #: EEH-16
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $2,250
Site Elements Parking
Access Aisles
Measurement: 3 count
502.3.3 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $2,925
EL ENCANTO HOSPITAL PAGE FACILITIES
524 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-17
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-208.2.1
A minimum 10% of the parking stalls (1 of every 6 of which must be Van Accessible) at the hospital and/or outpatient facility are not accessible.
Recommended Remediation:
A section of minimum 12 additional parking stalls and access aisle need to be added to the parking lot. These must include Van Accessible stalls and a compliant access route to the entrance of the facility. El Encanto has total of 214 parking spaces and only 10 accessible stalls.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $4,200
Site Elements Parking
Space Count
Measurement: 10 count
208.2 Quantity: 12 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hospital Facility
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $5,460 Comment #: EEH-18
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-504.2
The slope of the accessible parking spaces and aisles are steeper than the allowable 2.0%
Recommended Remediation:
Re-grade accessible surfaces so that the slope does not exceed
2.0%. This applies to the northern most stall and access aisle on the southern set of accessible parking spaces.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,000
Site Elements Parking
Accessible Stall
Measurement: 3.2 % grade
502.4 Quantity: 306 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Slope
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $1,300
EL ENCANTO HOSPITAL PAGE FACILITIES
525 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-26
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-216.3
This path from the accessible parking area is not part of the accessible route.
Recommended Remediation:
Chain this off and put a directional sign with ISA pointing towards the adjacent ramp. Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $961
Site Elements Exterior Access Route
Signage
Measurement: 1 count
216.6 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3 (16B)
Directional Signage
Severity:C
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $1,249 Route
Comment #: EEH-27
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.3.2
There is no level landing provided at the base of the parallel curb ramp with a slope no greater than the allowable 2.0% grade.
Recommended Remediation:
Remove and replace the parallel curb ramp including detectable warning surface and flush transitions. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Exterior Access Route
Curb Ramp
Measurement: 7.5 % grade
405.7.1 Quantity: 80 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Landing: Cross Slope
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $1,560 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
526 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-28
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.3.2
There is no level landing provided at the base of the parallel curb ramp with a slope no greater than the allowable 2.0% grade.
Recommended Remediation:
Remove and replace the parallel curb ramp including detectable warning surface and flush transitions. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Exterior Access Route
Curb Ramp
Measurement: 2.8 % grade
405.7.1 Quantity: 80 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Landing: Cross Slope
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $1,560 Route
Comment #: EEH-29
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.2.1
The running slope of the curb ramp exceeds the allowable 1:12 (8.33%) grade. Additional ramp features are noncompliant.
Recommended Remediation:
Remove and dispose of materials and replace and re-grade to provide an accessible curb ramp. Include detectable warning surface.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Exterior Access Route
Curb Ramp
Measurement: 8.5 % grade
405.2 Quantity: 80 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Running Slope
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $1,560 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
527 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-30
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 5 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:D
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $468 Route
Comment #: EEH-31
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-402.2
The curb ramps are not immediately adjacent and there is no cross walk striping defining the path of travel.
Recommended Remediation:
Create a cross walk striping to opposite ramp to facility entrance.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $0
Site Elements Exterior Access Route
Surface
Measurement: 1 count
Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Walk Striping
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $0 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
528 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-32
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Facility Entrance
Room/Spot: Passenger Drop-off Area
Priority: 1 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
N/A Quantity: 9 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $468 Route
Comment #: EEH-33
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Facility Entrance
Room/Spot: Passenger Drop-off Area
Priority: 1 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $468 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
529 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-19
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-503, 11B-206.4.10
The drop-off area is not generally accessible due to lack of signage that includes the ISA, blue striping and curb. A covered drop-off is required where there is 24 hour stays.
Recommended Remediation:
Provide blue striping for accessible loading zone, blue curb and install identification signage including the ISA. Provide cover for the drop-off zone.
Floor/Area: Facility Entrance
Room/Spot: Passenger Drop-off Site
Priority: 1 Estimated Direct Cost: $16,573
Site Elements Parking
Passenger Drop-off
Measurement: 1 count
206.2.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General Accessibility
Severity:C
Category Parking Precedence 4 Year 1 Cost with GC (30%): $21,545 Comment #: EEH-34
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Facility Entrance
Room/Spot: South POT from Entrance
Priority: 1 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $468 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
530 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-35
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-403.3
For a change of direction in the path of travel, there is no level space, minimum 5 ft X 5 ft, that has a slope of less than 2.0%.
Recommended Remediation:
Remove and dispose of existing pathway materials. Replace with a level area for change of direction. New cement and grading needed from tree all the way around the corner.
Floor/Area: Facility Entrance
Room/Spot: South POT from Entrance
Priority: 1 Estimated Direct Cost: $0
Site Elements Exterior Access Route
Slope
Measurement: 4.7 % grade
303.2/303.3 Quantity: 500 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Change of Direction
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $0 Route
Comment #: EEH-36
Facility: El Encanto Hospital
Deficiency:
Code References:
29016 CBC 11B-403.3
The running slope, parallel to the path of travel, exceeds the allowable 5% grade.
Recommended Remediation:
Remove and dispose of noncompliant route materials and
replace and re-grade to create a ramp. Add ramp features such as compliant landings and handrails.
Floor/Area: Facility Entrance
Room/Spot: South POT from Entrance
Priority: 1 Estimated Direct Cost: $2,100
Site Elements Exterior Access Route
Slope
Measurement: 8.8 % grade
405.2 Quantity: 140 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Running Slope
Severity:B
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $2,730 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
531 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-50
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path.
Recommended Remediation:
Remove/Relocate object so that it does not obstruct the accessible circulation path, and is not located within door maneuvering clearance.
Floor/Area: Santa Monica Room
Room/Spot:
Priority: 2 Estimated Direct Cost: $180
Rooms and Spaces Interior Access Route
Protrusion
Measurement: 71 inches
N/A Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $234 Route
Comment #: EEH-37
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path, and operable parts are outside of the reach ranges.
Recommended Remediation:
Lower the obstructing object so that the lowest edge is either not greater than 27 inches above the floor or so that it is greater than 80 inches above the floor. Fire Extinguisher Cabinet. There is 1 in each courtyard of the facility. Relocate so the highest operable part does not exceed 48 inches above finished floor.
Floor/Area: North Courtyard
Room/Spot: N/A
Priority: 1 Estimated Direct Cost: $360
Site Elements Exterior Access Route
Protrusion
Measurement: 46 inches
N/A Quantity: 4 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $468 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
532 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-51
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 1011.4
There is no provided tactile exit sign at the doorway leading to a grade level exit.
Recommended Remediation:
Install one tactile exit sign, compliant with 2016 CBC 11B-703, where illuminated exit signs are provided. There are
approximately 20 illuminated exit signs facility wide.
Floor/Area: Facility Wide
Room/Spot: Illuminated Exits
Priority: 4 Estimated Direct Cost: $19,220
Rooms and Spaces Interior Doors
Signage
Measurement: 20 count
216.2/703.4.1&2 Quantity: 20 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16(a))
Tactile Exit Sign
Severity:A
Category Interior Doors Precedence 8 Year 3 Cost with GC (30%): $24,986 Comment #: EEH-52
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-302.2
The edges of the carpet and/or mat is not securely attached to the floor to minimize tripping hazards.
Recommended Remediation:
Secure the carpet/mat at the edges to minimize tripping hazards.
Floor/Area: Room 418
Room/Spot: N/A
Priority: 4 Estimated Direct Cost: $0
Rooms and Spaces Interior Access Route
Carpets and Mats
Measurement: 1 count
302.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.3 Secure Floor
Attachment
Severity:A
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $0 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
533 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-53
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path.
Recommended Remediation:
Remove object so that it does not obstruct the accessible circulation path. Cannot Raise these because of minimum 18 inches clearance to the ceiling for fire sprinkler operation, must also not be located within door clearances.
Floor/Area: Hermosa Room
Room/Spot: N/A
Priority: 2 Estimated Direct Cost: $180
Rooms and Spaces Interior Access Route
Protrusion
Measurement: 2 count
N/A Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $234 Route
Comment #: EEH-54
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path.
Recommended Remediation:
Remove/Relocate object so that it does not obstruct the accessible circulation path. Floor/Area: Physical Therapy Room Room/Spot: N/A
Priority: 2 Estimated Direct Cost: $90
Rooms and Spaces Interior Access Route
Protrusion
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $117 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
534 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-43
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-703.7.2.6.3
The color of the geometric unisex door sign does not provide visual contrast between the geometric shapes and/or color of the door.
Recommended Remediation:
Remove and replace unisex geometric door sign. New door signs shall provide visual contrast between the circle and triangle symbols and with the color of the door.
Floor/Area: ADA Restroom
Room/Spot: N/A
Priority: 5 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Geometric Sign
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Unisex Contrast
Severity:D
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249 Comment #: EEH-44
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-606.6
The center line of the lavatory is less than the allowable 18 inches from the side wall.
Recommended Remediation:
Remove and relocate the lavatory including all associated plumbing fixtures. This currently meets the federal requirements so only must be completed with next tenant improvements.
Floor/Area: ADA Restroom
Room/Spot: N/A
Priority: 5 Estimated Direct Cost: $0
Public Toilet Rooms Lavatories (Sinks)
Location
Measurement: 17.5 inches
606 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Side Wall Distance
Severity:D
Category Lavatories (Sinks) Precedence 8 Year 3 Cost with GC (30%): $0
EL ENCANTO HOSPITAL PAGE FACILITIES
535 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-45
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-603.3
The bottom edge of the reflecting surface of a mirror over the lavatory or countertop is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Lower mirror or install another mirror with bottom edge of reflective surface 35" maximum above finish floor. Floor/Area: ADA Restroom Room/Spot: N/A
Priority: 3 Estimated Direct Cost: $1,200
Public Toilet Rooms Room and Space
Mirror
Measurement: 40.5 inches
603.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $1,560 Comment #: EEH-46
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-603.5
The operable parts of the unobstructed soap dispenser is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Adjust dispenser or provide additional accessible dispensers.
Floor/Area: ADA Restroom
Room/Spot: N/A
Priority: 3 Estimated Direct Cost: $163
Public Toilet Rooms Dispensers
Soap Dispenser
Measurement: 57 inches
603 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.23.7 Height
Severity:C
Category Dispensers Precedence 8 Year 3 Cost with GC (30%): $212
EL ENCANTO HOSPITAL PAGE FACILITIES
536 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-47
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-604.5.2
The rear grab bar does not extend a minimum of 24 inches from the center line of the toilet on the open side.
Recommended Remediation:
Remove and relocate the rear grab bar so that it extends a minimum 24 inches from the center line of the toilet on the open side.
Floor/Area: ADA Restroom
Room/Spot: N/A
Priority: 3 Estimated Direct Cost: $1,000
Public Toilet Rooms Toilet Compartment
Rear Grab Bar (Stalls)
Measurement: 23 inches
604.5 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16)(a)
Length
Severity:A
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $1,300 (Stalls)
Comment #: EEH-48
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-606.5
The pipe insulation at the lavatory has become loose.
Recommended Remediation:
Lift insulation coverings up and secure in place. Any securement shall be protected from skin contact Floor/Area: ADA Restroom Room/Spot: N/A
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Lavatories (Sinks)
Exposed Pipes
Measurement: 1 count
606.5 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.24.6 Pipe Insulation
Severity:C
Category Lavatories (Sinks) Precedence 8 Year 3 Cost with GC (30%): $117
EL ENCANTO HOSPITAL PAGE FACILITIES
537 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-49
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-604.5.1
The side grab bar does not extend a minimum 54 inches from the rear wall.
Recommended Remediation:
Relocate the side grab bar to extend 54 inches from the back wall and 24 inches from the face of the water closet. Floor/Area: ADA Restroom Room/Spot: N/A
Priority: 3 Estimated Direct Cost: $1,000
Public Toilet Rooms Toilet Compartment
Side Grab Bar (Stalls)
Measurement: 51 inches
604.5 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16)(a)
Location
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $1,300 (Stalls)
Comment #: EEH-55
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path.
Recommended Remediation:
Remove/Relocate object so that it does not obstruct the accessible circulation path. There are two shelves NOT under the TV that have no cane detectable barrier.
Floor/Area: Newport Room
Room/Spot: N/A
Priority: 2 Estimated Direct Cost: $180
Rooms and Spaces Interior Access Route
Protrusion
Measurement: 2 count
N/A Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $234 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
538 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-38
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-406.5.12
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Install a detectable warning surface compliant with 2016 CBC 11B-705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: North Entrance
Room/Spot: Gate
Priority: 1 Estimated Direct Cost: $572
Site Elements Exterior Access Route
Flush Transition
Measurement: 1 count
N/A Quantity: 8 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Detectable Warning
Surface
Severity:A
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $744 Route
Comment #: EEH-39
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-404.2.10
The bottom 10 inches of gates at the are not smooth.
Recommended Remediation:
Install smooth kick plates across the bottom of all gates.
Floor/Area: North Entrance
Room/Spot: Bus Pickup
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Exterior Access Route
Gate
Measurement: 1 count
Quantity: 8 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
Kick Plate
Severity:C
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $1,560 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
539 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-40
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-404.2.10
The bottom 10 inches of gates at the are not smooth.
Recommended Remediation:
Install smooth kick plates across the bottom of all gates.
Floor/Area: South Courtyard
Room/Spot: Gate
Priority: 1 Estimated Direct Cost: $150
Site Elements Exterior Access Route
Gate
Measurement: 1 count
Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Kick Plate
Severity:C
Category Exterior Access Precedence 4 Year 1 Cost with GC (30%): $195 Route
Comment #: EEH-56
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path.
Recommended Remediation:
Relocate the piano so that it provides a cane detectable barrier.
Floor/Area: South Courtyard
Room/Spot: N/A
Priority: 2 Estimated Direct Cost: $90
Rooms and Spaces Interior Access Route
Protrusion
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $117 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
540 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-60
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-306.2, 306.3
A knee space of minimum 27 inches high by 30 inches wide is not provided at wheelchair accessible seating.
Recommended Remediation:
Alter table or work surface to provide compliant knee space.
Floor/Area: Computer Room
Room/Spot: N/A
Priority: 2 Estimated Direct Cost: $1,300
Rooms and Spaces Seating
Dining and Work
Surfaces
Measurement: 9.5 inches
306.3.2/902.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.32.3 Knee Space
Severity:C
Category Seating Precedence 8 Year 3 Cost with GC (30%): $1,690 Comment #: EEH-61
Facility: El Encanto Hospital
Deficiency:
Code References:
CBC 11B-216.2, CBC 11B-703.3
The room identification sign does not provide braille.
Recommended Remediation:
Install a tactile sign that provides Braille characters.
Approximately 150 room ID signs. Develop an entire facility package.
Floor/Area: Facility Wide
Room/Spot: N/A
Priority: 2 Estimated Direct Cost: $144,150
Rooms and Spaces Room ID Signage
Signage
Measurement: 1 count
216.2/703.4.1&2 Quantity: 150 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16(a))
Braille
Severity:C
Category Room ID Signage Precedence 8 Year 3 Cost with GC (30%): $187,395
EL ENCANTO HOSPITAL PAGE FACILITIES
541 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-57
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path.
Recommended Remediation:
Add a tactile warning such as a permanent planter or partial wall.
Floor/Area: Resident Telephone
Room/Spot: N/A
Priority: 2 Estimated Direct Cost: $90
Rooms and Spaces Interior Access Route
Protrusion
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $117 Route
Comment #: EEH-62
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-217.4.1
No provided telephone has TTY. (Interactive text-based system).
Recommended Remediation:
Install a TTY system on at least one available public telephone.
Floor/Area: Resident Telephone
Room/Spot: N/A
Priority: 4 Estimated Direct Cost: $90
Additional Access Public Telephones
TTY
Measurement: 1 count
308.2.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.30.6 General Accessibility
Severity:C
Category Public Telephones Precedence 8 Year 3 Cost with GC (30%): $117
EL ENCANTO HOSPITAL PAGE FACILITIES
542 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-58
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-404.2.9
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: Front Lobby
Room/Spot: Entrance
Priority: 2 Estimated Direct Cost: $90
Rooms and Spaces Doors, Doorways,
Door Operation Gates
Measurement: 15 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:C
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $117 Gates
Comment #: EEH-59
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-404.2.10
The bottom 10 inches of gates at the are not smooth.
Recommended Remediation:
Install smooth kick plates across the bottom of all gates.
Floor/Area: Front Lobby
Room/Spot: 2nd Door
Priority: 2 Estimated Direct Cost: $150
Rooms and Spaces Interior Access Route
Interior Doors
Measurement: 1 count
Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Kick Plate
Severity:C
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $195 Route
EL ENCANTO HOSPITAL PAGE FACILITIES
543 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EEH-41
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-404.2.9, 404.2.2, 404.2.3
The force required to operate the door exceeds the allowable 5 lbf. Each door leaf is only 30 inches wide.
Recommended Remediation:
Replace the doors with one that provides minimum 32 inches clearance when opened to 90 degrees. Floor/Area: Front Lobby Room/Spot: Entrance
Priority: 1 Estimated Direct Cost: $1,991
Entrance Doors, Doorways,
Door Operation Gates
Measurement: 30 inches
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:C
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $2,588 Gates
Comment #: EEH-42
Facility: El Encanto Hospital
Deficiency:
Code References:
2016 CBC 11B-404.2.4.4
The floor surface of the maneuvering clearance on both sides of the door exceeds the allowable slope of 2.0%.
Recommended Remediation:
Remove and dispose of surface materials. Regrade and replace the concrete so that a level landing with slope less than 2.0 % grade is provided. 1
Floor/Area: East Entrance
Room/Spot: Entrance
Priority: 1 Estimated Direct Cost: $2,250
Entrance Doors, Doorways,
Clearance Space Gates
Measurement: 5.1 % grade
405.2 Quantity: 150 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Cross Slope
Severity:B
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $2,925 Gates
EL ENCANTO HOSPITAL PAGE FACILITIES
544 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
EXPO CENTER
EXPO CENTER PAGE FACILITIES
545 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Site Plan:
EXPO CENTER PAGE FACILITIES
546 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Floor Plan:
EXPO CENTER PAGE FACILITIES
547 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
FACILITY: EXPO CENTER
Facility Description:
Facility was constructed in the year .
Facility Address:
This facility is used for the following programs:
1982
Equestrian Center
Private Banquets/Parties/Events
Open-air stadium (horse shows, rodeo, soccer, boxing,
motorcycles, dog shows, competitions, etc.)
Office building for facility office staff
16200 Temple Avenue
EXPO CENTER PAGE FACILITIES
548 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-148
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-221.2.1.1
There are not an adequate number of wheelchair spaces
provided. See standards for acceptable amount of seating.
Recommended Remediation:
Reconfigure available seating to provide an adequate number of wheelchair accessible spaces. There needs to be 51 wheel chair designated spaces including a companion seat. As per the brochure stating 5000 spectator occupancy and table CBC 11B-221.2.1.1. Each section needs a raised seating area. Verify with fire marshal about whether or not companion seating can be made at the wall along the path with railing. This is the more economical solution.
Floor/Area: Grand Arena
Room/Spot: Bleachers
Priority: 1 Estimated Direct Cost: $0
Rooms and Spaces Seating
Assembly Areas
Measurement: 4 count
221.2.1.1 Quantity: 51 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(9) (a)
Wheelchair Space:
Count
Severity:C
Category Seating Precedence 8 Year 3 Cost with GC (30%): $0 Comment #: EXPO-031
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-405.2
The ramp has no space limitations and the running slope, parallel to the path of travel exceeds the allowable 8.33% grade.
Recommended Remediation:
Relocate the ramp so that the slope does not exceed the allowable 8.33%. Modular ramp Floor/Area: Grand Arena
Room/Spot: Accessible Seating Ramp
Priority: 1 Estimated Direct Cost: $15
Site Elements Exterior Access Route
Ramps
Measurement: 9.6 % grade
405.7 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Running Slope
Severity:B
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $20 Route
EXPO CENTER PAGE FACILITIES
549 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-032
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-505.10
The handrail extensions do not extend 12" minimum before turning to terminate.
Recommended Remediation:
Alter the handrails extensions are not parallel to the ground.
Handrails must be level over the ramp landing. Floor/Area: Grand Arena Room/Spot: Accessible Seating Ramp
Priority: 1 Estimated Direct Cost: $500
Site Elements Exterior Access Route
Ramps
Measurement: 2 count
405.8/505 Quantity: 2 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Handrail Extensions
Severity:B
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $650 Route
Comment #: EXPO-033
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 1015.2, 2016 CBC 1015.4
An abrupt drop-off exists that is greater 30 inches, and the guardrail openings allow for a 4 inch diameter sphere to pass through.
Recommended Remediation:
Add a guardrail and edge protection that does not allow the passing of a 4 inch diameter sphere. Floor/Area: Grand Arena Room/Spot: Bleachers
Priority: 1 Estimated Direct Cost: $450
Site Elements Exterior Access Route
Drop-off
Measurement: 1 count
206.4.3 Quantity: 18 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
Guardrails
Severity:B
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $585 Route
EXPO CENTER PAGE FACILITIES
550 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-034
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.4.1
Warning stripes are not provided at all treads and/or the upper approach.
Recommended Remediation:
Add contrasting stripes between 2 and 4 inches wide across the entire width of each tread and/or the upper approach. Bleachers require warning stripes. Approx. 4 feet per step.
Floor/Area: Grand Arena
Room/Spot: Bleachers
Priority: 5 Estimated Direct Cost: $4,620
Site Elements Exterior Access Route
Stairs
Measurement: 0 count
N/A Quantity: 154 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Warning Stripes
Severity:D
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $6,006 Route
Comment #: EXPO-142
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 1015.2, 2016 CBC 1015.4
An abrupt drop-off exists that is greater 30 inches, and the guardrail openings allow for a 4 inch diameter sphere to pass through.
Recommended Remediation:
Add a guardrail and edge protection that does not allow the passing of a 4 inch diameter sphere. Attach mesh backing is the most economical option.
Floor/Area: Grand Arena
Room/Spot: Bleachers
Priority: 1 Estimated Direct Cost: $18,750
Rooms and Spaces Interior Access Route
Drop-off
Measurement: 6.5 inches
206.4.3 Quantity: 750 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
Guardrails
Severity:C
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $24,375 Route
EXPO CENTER PAGE FACILITIES
551 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-035
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-206.1
If the public are allowed in the announcer's booth than there must be accessible features.
Recommended Remediation:
Provide a wheelchair lift.
Floor/Area: Grand Arena
Room/Spot: Announcer Booth
Priority: 1 Estimated Direct Cost: $0
Site Elements Exterior Access Route
General Accessibility
Measurement: 1 count
206.4.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Public Areas
Severity:C
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $0 Route
Comment #: EXPO-036
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path.
Recommended Remediation:
Provide cane detectable barriers all along the underside of the bleachers. Approximately 500 linear feet. Existing partitions are acceptable, or relocate picnic benches so they are not located under bleachers.
Floor/Area: Grand Arena
Room/Spot: Tables Under Bleachers
Priority: 1 Estimated Direct Cost: $45,000
Site Elements Exterior Access Route
Protrusion
Measurement: 79 inches
N/A Quantity: 500 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $58,500 Route
EXPO CENTER PAGE FACILITIES
552 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-149
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-902.2
A minimum of 5% (with at least 1) of the total seating and standing space is not accessible for use of people in
wheelchairs.
Recommended Remediation:
Add an accessible table or work surface that provides compliant knee space. Need minimum 5 wheelchair seating spaces. Get 3 new picnic tables with seating.
Floor/Area: Grand Arena
Room/Spot: Tables Under Bleachers
Priority: 1 Estimated Direct Cost: $3,900
Rooms and Spaces Seating
Dining and Work
Surfaces
Measurement: 0 inches
402.2 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.7 General Accessibility
Severity:B
Category Seating Precedence 8 Year 3 Cost with GC (30%): $5,070 Comment #: EXPO-037
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path.
Recommended Remediation:
Provide cane detectable barriers all along the underside of the bleachers at angled support beams. Approximately 32 locations, or create a barrier so no one can walk under bleachers. All angled beams. At 32 locations.
Floor/Area: Grand Arena
Room/Spot: Tables Under Bleachers
Priority: 5 Estimated Direct Cost: $2,880
Site Elements Exterior Access Route
Protrusion
Measurement: 79 count
N/A Quantity: 32 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:D
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $3,744 Route
EXPO CENTER PAGE FACILITIES
553 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-038
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.4.1
Warning stripes are not provided at all treads and/or the upper approach.
Recommended Remediation:
Add contrasting stripes between 2 and 4 inches wide across the entire width of each tread and/or the upper approach. Floor/Area: El Patio Cafe Room/Spot: Both Stairs
Priority: 1 Estimated Direct Cost: $768
Site Elements Exterior Access Route
Stairs
Measurement: 16 count
N/A Quantity: 128 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Warning Stripes
Severity:A
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $998 Route
Comment #: EXPO-039
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-505.4
The stairs do not provide compliant handrails.
Recommended Remediation:
Modify handrails as needed to provide compliant handrails and extensions. Curbs must be included in stair case. Extend the handrails on both stair cases.
Floor/Area: El Patio Cafe
Room/Spot: Exterior Access Route
Priority: 5 Estimated Direct Cost: $1,840
Site Elements Exterior Access Route
Stairs
Measurement: 2 count
505.2 Quantity: 16 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Handrails
Severity:D
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $2,392 Route
EXPO CENTER PAGE FACILITIES
554 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-040
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-303.2
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: El Patio Cafe
Room/Spot: Exterior Access Route
Priority: 1 Estimated Direct Cost: $1,440
Site Elements Exterior Access Route
Surface Continuity
Measurement: .75 inches
303.2/303.3 Quantity: 16 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $1,872 Route
Comment #: EXPO-041
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-405.7
There is no landing provided at the bottom of the ramp with a cross slope of maximum 2.0%, a length of 6 feet and a width equal to that of the ramp.
Recommended Remediation:
Alter ramp landing to provide level platform of 60 inches for the full width of the ramp. Include handrail extensions. Floor/Area: El Patio Cafe Room/Spot: Exterior Access Route
Priority: 1 Estimated Direct Cost: $28,286
Site Elements Exterior Access Route
Ramps
Measurement: 5.3 % grade
405.7 Quantity: 40 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Landings: Bottom
Severity:B
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $36,772 Route
EXPO CENTER PAGE FACILITIES
555 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-042
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-405.9
Edge protection is not provided full length of ramp at both sides.
Recommended Remediation:
Must provide wheel guide in line with the handrails.
Floor/Area: El Patio Cafe
Room/Spot: Exterior Access Route
Priority: 1 Estimated Direct Cost: $28,286
Site Elements Exterior Access Route
Ramps
Measurement: 0 count
405.9 Quantity: 130 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Edge Protection
Severity:B
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $36,772 Route
Comment #: EXPO-043
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 1015.2, 2016 CBC 1015.4
An abrupt drop-off exists that is greater 30 inches, and the guardrail openings allow for a 4 inch diameter sphere to pass through.
Recommended Remediation:
Add a guardrail and edge protection that does not allow the passing of a 4 inch diameter sphere. Provide guardrail, 42 inch minimum height, along the entire outside of the ramp.
Floor/Area: El Patio Cafe
Room/Spot: Exterior Access Route
Priority: 1 Estimated Direct Cost: $1,300
Site Elements Exterior Access Route
Drop-off
Measurement: 1 count
206.4.1 Quantity: 52 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
Guardrails
Severity:B
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $1,690 Route
EXPO CENTER PAGE FACILITIES
556 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-150
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-902.2
A minimum of 5% (with at least 1) of the total seating and standing space is not accessible for use of people in
wheelchairs.
Recommended Remediation:
Add an accessible table or work surface that provides compliant knee space. Provide 4 accessible seating locations based on existing seating count of 76 available seats. If seats are added, the ADA ratio must be maintained.
Floor/Area: El Patio Cafe
Room/Spot: Picnic Area
Priority: 1 Estimated Direct Cost: $5,200
Rooms and Spaces Seating
Dining and Work
Surfaces
Measurement: 0 count
402.2 Quantity: 4 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.7 General Accessibility
Severity:C
Category Seating Precedence 8 Year 3 Cost with GC (30%): $6,760 Comment #: EXPO-044
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-505.10
The handrail extensions do not extend 12" minimum before turning to terminate.
Recommended Remediation:
Remove and replace the handrails. Provide extensions at the top at bottom of the stairs that extend 12 inches parallel to the ground beyond the last tread.
Floor/Area: El Patio Cafe
Room/Spot: Stairs
Priority: 1 Estimated Direct Cost: $11,500
Site Elements Exterior Access Route
Stairs
Measurement: 4 feet
505.1 Quantity: 100 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Handrail Extensions
Severity:A
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $14,950 Route
EXPO CENTER PAGE FACILITIES
557 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-062
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-703.6.2
Color of door sign does not provide visual contrast with the color of the door.
Recommended Remediation:
Remove and replace door sign. New door signs shall provide visual contrast with the color of the door Floor/Area: El Patio Cafe Room/Spot: Men’s Restroom
Priority: 5 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Geometric Sign
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:D
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249 Comment #: EXPO-063
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-703.1
A tactile wall sign, identifying the public restroom, is not provided.
Recommended Remediation:
Install new tactile wall sign providing raised character text and Braille. Locate sign at latch side of door. Floor/Area: El Patio Cafe Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Tactile Sign
Measurement: 1 count
216.2/703.4.1&2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16(a))
General
Severity:C
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249
EXPO CENTER PAGE FACILITIES
558 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-064
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: El Patio Cafe
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Entrance
Door Operation
Measurement: 11 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Entrance Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: EXPO-065
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-606.5
c
Recommended Remediation:
Install new insulation to cover pipes.
Floor/Area: El Patio Cafe
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Lavatories (Sinks)
Exposed Pipes
Measurement: 1 count
606.5 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.24.6 Pipe Insulation
Severity:C
Category Lavatories (Sinks) Precedence 8 Year 3 Cost with GC (30%): $117
EXPO CENTER PAGE FACILITIES
559 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-066
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-603.3
The bottom edge of the reflecting surface of a mirror over the lavatory or countertop is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Lower mirror or install another mirror with bottom edge of reflective surface 35" maximum above finish floor. Floor/Area: El Patio Cafe Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $1,200
Public Toilet Rooms Room and Space
Mirror
Measurement: 40.5 inches
603.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $1,560 Comment #: EXPO-067
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-307.2
Bottom of paper towel dispenser is greater than 27" above finish floor and projects greater than 4" from wall.
Recommended Remediation:
Replace with semi-recessed or recessed paper towel dispenser or extend waste receptacle, which is below, outward so
maximum 4" projection beyond.
Floor/Area: El Patio Cafe
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Dispensers
Paper Towel
Measurement: 42 inches
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.4.1 Protrusion
Severity:C
Category Dispensers Precedence 8 Year 3 Cost with GC (30%): $117
EXPO CENTER PAGE FACILITIES
560 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-068
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-213.3.1
There are a minimum of 6 total toilet compartments and urinals and the number of ambulatory compartments is not equal to the number of accessible compartments.
Recommended Remediation:
Provide an ambulatory compartment with compliant grab bars and an outward swinging stall door. Floor/Area: El Patio Cafe Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms General Accessibility
Accessory Count
Measurement: 0 count
Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Ambulatory
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $117 Accessibility
Comment #: EXPO-069
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.1.2
The accessible stall door is not self-closing.
Recommended Remediation:
Replace self-closing hinges.
Floor/Area: El Patio Cafe
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $250
Public Toilet Rooms Stall Door
Closer
Measurement: 1 count
404.2.8.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.10 Self-closing
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $325
EXPO CENTER PAGE FACILITIES
561 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-070
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.1.2, 2016 CBC 11B-404.2.7
The accessible stall door lock is not operable with one hand and/or requires tight grasping, pinching or twisting of the wrist to operate.
Recommended Remediation:
Replace stall door locks. Provide sliding lock not rotating lock.
Floor/Area: El Patio Cafe
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Stall Door
Hardware
Measurement: 1 count
309/404.2.7 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 Lock
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: EXPO-071
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-609.3
The rear grab bar does not provide minimum allowable space of 1 1/2 inches between the bottom of the grab bar and any protruding objects below.
Recommended Remediation:
Relocate the grab bar. Lower the toilet paper dispenser and/or raise the rear grab bar. Floor/Area: El Patio Cafe
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $1,000
Public Toilet Rooms Toilet Compartment
Grab Bars (Both) (Stalls)
Measurement: .75 inches
609.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.17.6 Clearance
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $1,300 (Stalls)
EXPO CENTER PAGE FACILITIES
562 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-072
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-603.5
The operable part of the toilet seat dispenser is higher than the allowable 40 inches.
Recommended Remediation:
Adjust the height of the dispenser so that the highest operable part is less than 40 inches AFF. This meets the federal requirements.
Floor/Area: El Patio Cafe
Room/Spot: Men’s Restroom
Priority: 5 Estimated Direct Cost: $2,500
Public Toilet Rooms Toilet Compartment
Seat Cover Dispenser (Stalls)
Measurement: 44 inches
603 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.23.7 Height
Severity:D
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $3,250 (Stalls)
Comment #: EXPO-073
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.6
The flush control is not on the open side of the accessible toilet (away from the partition or wall).
Recommended Remediation:
Move the flush control so that it is on the open side of the toilet.
Adjust plumbing line. Floor/Area: El Patio Cafe
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $0
Public Toilet Rooms Toilet Compartment
Water Closet (Toilet) (Stalls)
Measurement: 1 count
604.6 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.27.4/4.16.5
Flush Control
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $0 (Stalls)
EXPO CENTER PAGE FACILITIES
563 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-074
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-308.2.1
The top of the hook is greater than 48 inches above finished floor.
Recommended Remediation:
Relocate hook or add one at compliant height.
Floor/Area: El Patio Cafe
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Accessories
Hook
Measurement: 62 inches
604.8.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Accessories Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: EXPO-075
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-305.7.1
The centerline of urinal is less than 18 inches from adjacent wall, which is greater than 24 inches deep.
Recommended Remediation:
Remove the wall adjacent to the urinal to provide the compliant space. Floor/Area: El Patio Cafe
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $4,322
Public Toilet Rooms Room and Space
Urinal
Measurement: 13 inches
605.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.18.3 Location
Severity:C
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $5,619
EXPO CENTER PAGE FACILITIES
564 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-076
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-703.6.2
Color of door sign does not provide visual contrast with the color of the door.
Recommended Remediation:
Remove and replace door sign. New door signs shall provide visual contrast with the color of the door Floor/Area: El Patio Cafe Room/Spot: Women’s Restroom
Priority: 5 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Geometric Sign
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:D
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249 Comment #: EXPO-077
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-703.1
A tactile wall sign, identifying the public restroom, is not provided.
Recommended Remediation:
Install new tactile wall sign providing raised character text and Braille. Locate sign at latch side of door. Floor/Area: El Patio Cafe Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Tactile Sign
Measurement: 1 count
216.2/703.4.1&2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16(a))
General
Severity:C
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249
EXPO CENTER PAGE FACILITIES
565 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-078
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: El Patio Cafe
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Entrance
Door Operation
Measurement: 9 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:C
Category Entrance Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: EXPO-079
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-307.2
Bottom of paper towel dispenser is greater than 27" above finish floor and projects greater than 4" from wall.
Recommended Remediation:
Replace with semi-recessed or recessed paper towel dispenser or extend waste receptacle, which is below, outward so
maximum 4" projection beyond.
Floor/Area: El Patio Cafe
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Dispensers
Paper Towel
Measurement: 49 inches
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.4.1 Protrusion
Severity:C
Category Dispensers Precedence 8 Year 3 Cost with GC (30%): $117
EXPO CENTER PAGE FACILITIES
566 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-080
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-603.3
The bottom edge of the reflecting surface of a mirror over the lavatory or countertop is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Lower mirror or install another mirror with bottom edge of reflective surface 35" maximum above finish floor. Floor/Area: El Patio Cafe Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $1,200
Public Toilet Rooms Room and Space
Mirror
Measurement: 41.5 inches
603.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $1,560 Comment #: EXPO-081
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-226.4, 2016 CBC 11B-304.3
The space clear space in front of the baby changing station does not provide a clear floor turning space of 60 inches x 60 inches. It also does not provide 30 inches by 48 inches clear floor space when in the down position.
Recommended Remediation:
Relocate the baby changing station to a place that provides a minimum clear floor turning space of 60 inches X 60 inches with minimum allowable knee clearance of 27 inches.
Floor/Area: El Patio Cafe
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $600
Public Toilet Rooms Accessories
Baby Changing Table
Measurement: 36 inches
226.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Clear Floor Space
Severity:C
Category Accessories Precedence 8 Year 3 Cost with GC (30%): $780
EXPO CENTER PAGE FACILITIES
567 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-082
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.1.2
The accessible stall door is not self-closing.
Recommended Remediation:
Replace self-closing hinges.
Floor/Area: El Patio Cafe
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $250
Public Toilet Rooms Stall Door
Closer
Measurement: 1 count
404.2.8.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.10 Self-closing
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $325 Comment #: EXPO-083
Facility: Expo Center
Deficiency:
Code References:
2017 CBC 11B-604.8.1.2, 2016 CBC 11B-404.2.7
The accessible stall door lock is not operable with one hand and/or requires tight grasping, pinching or twisting of the wrist to operate.
Recommended Remediation:
Replace stall door locks.
Floor/Area: El Patio Cafe
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Stall Door
Hardware
Measurement: 1 count
309/404.2.7 Quantity: 1 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 Lock
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $117
EXPO CENTER PAGE FACILITIES
568 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-084
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.2.2
The accessible stall door does not provide pull handles on both sides of the door that are operable by one hand and do not require tight grasping, pinching or twisting of the wrist.
Recommended Remediation:
Add a pull handle (typically a u-pull handle) to the missing side of the door. Floor/Area: El Patio Cafe
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Stall Door
Hardware
Measurement: 1 count
309/404.2.7 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 U-Pull
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: EXPO-085
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.3.1
The water closet does not provide a clear space of 60 inches width in front of the toilet.
Recommended Remediation:
Relocate partition wall at Water Closet.
Floor/Area: El Patio Cafe
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $2,500
Public Toilet Rooms Toilet Compartment
Clearance Space (Stalls)
Measurement: 58.5 inches
604.2/604.8 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.16.2 Width
Severity:C
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $3,250 (Stalls)
EXPO CENTER PAGE FACILITIES
569 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-086
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-609.4
The side grab bar is mounted so that its centerline is greater than 33 inches above the finished floor.
Recommended Remediation:
Relocate side grab bar. Insure you maintain 1.5 inches clearance to the toilet paper dispenser. It will need to be lowered. Floor/Area: El Patio Cafe Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $1,000
Public Toilet Rooms Toilet Compartment
Side Grab Bar (Stalls)
Measurement: 34 inches
604.5 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16)(a)
Height
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $1,300 (Stalls)
Comment #: EXPO-087
Facility: Expo Center
Deficiency:
Code References:
2017 CBC 11B-603.5
The operable part of the toilet seat dispenser is higher than the allowable 40 inches.
Recommended Remediation:
Adjust the height of the dispenser so that the highest operable part is less than 40 inches AFF. Meets federal requirements. Floor/Area: El Patio Cafe Room/Spot: Women’s Restroom
Priority: 5 Estimated Direct Cost: $2,500
Public Toilet Rooms Toilet Compartment
Seat Cover Dispenser (Stalls)
Measurement: 42 inches
603 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.23.7 Height
Severity:D
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $3,250 (Stalls)
EXPO CENTER PAGE FACILITIES
570 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-088
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-308.2.1
The top of the hook is greater than 48 inches above finished floor.
Recommended Remediation:
Relocate hook or add one at compliant height.
Floor/Area: El Patio Cafe
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Accessories
Hook
Measurement: 62 inches
604.8.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Accessories Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: EXPO-089
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-213.3.1
There are a minimum of 6 total toilet compartments and number of ambulatory compartments is not equal to the number of accessible compartments.
Recommended Remediation:
Provide an ambulatory compartment with compliant grab bars and an outward swinging stall door. Floor/Area: El Patio Cafe Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms General Accessibility
Accessory Count
Measurement: 0 count
Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Ambulatory
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $117 Accessibility
EXPO CENTER PAGE FACILITIES
571 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-051
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: El Patio Cafe
Room/Spot: Cafe
Priority: 2 Estimated Direct Cost: $90
Entrance Doors, Doorways,
Door Operation Gates
Measurement: 10 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $117 Gates
Comment #: EXPO-052
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.4.2
For front approach to the pull side of the door there is less than 18 inches of maneuvering clearance beyond the latch side and/or less than 60 inches clear depth.
Recommended Remediation:
To provide a compliant clearance make the door swing outward instead of inward. Floor/Area: El Patio Cafe
Room/Spot: Cafe
Priority: 1 Estimated Direct Cost: $1,400
Entrance Doors, Doorways,
Clearance Space Gates
Measurement: 6 inches
404.2.4.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.6 Pull Side Front
Approach
Severity:B
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $1,820 Gates
EXPO CENTER PAGE FACILITIES
572 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-053
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: El Patio Cafe
Room/Spot: Cafe
Priority: 1 Estimated Direct Cost: $90
Entrance Doors, Doorways,
Door Operation Gates
Measurement: 12 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $117 Gates
Comment #: EXPO-151
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-703.1
There is no tactile room ID sign provided.
Recommended Remediation:
Provide tactile room ID signs at each room entrance.
Floor/Area: El Patio Cafe
Room/Spot: Cafe
Priority: 2 Estimated Direct Cost: $961
Rooms and Spaces Room ID Signage
Signage
Measurement: 1 count
216.2/703.4.1&2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16(a))
Tactile Signs
Severity:C
Category Room ID Signage Precedence 8 Year 3 Cost with GC (30%): $1,249
EXPO CENTER PAGE FACILITIES
573 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-152
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-902.2
A minimum of 5% (with at least 1) of the total seating and standing space is not accessible for use of people in
wheelchairs.
Recommended Remediation:
Add an accessible table or work surface that provides compliant knee space. Floor/Area: Snack Bar and Restrooms
Room/Spot: Picnic Table Area
Priority: 2 Estimated Direct Cost: $1,300
Rooms and Spaces Seating
Dining and Work
Surfaces
Measurement: 0 count
402.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.3.7 General Accessibility
Severity:C
Category Seating Precedence 8 Year 3 Cost with GC (30%): $1,690 Comment #: EXPO-090
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-216.8.1
No geometric sign exists at the entrance to the public restroom to indicate the restroom gender.
Recommended Remediation:
Provide a sign with the appropriate geometric symbol.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Women’s Restroom
Priority: 5 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Geometric Sign
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:D
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249
EXPO CENTER PAGE FACILITIES
574 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-091
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-703.1
A tactile wall sign, identifying the public restroom, is not provided.
Recommended Remediation:
Install new tactile wall sign providing raised character text and Braille. Locate sign at latch side of door. Floor/Area: Snack Bar and Restrooms Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Tactile Sign
Measurement: 1 count
216.2/703.4.1&2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16(a))
General
Severity:C
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249 Comment #: EXPO-092
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Women’s Restroom
Priority: 2 Estimated Direct Cost: $90
Public Toilet Rooms Entrance
Door Operation
Measurement: 6 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Entrance Precedence 8 Year 3 Cost with GC (30%): $117
EXPO CENTER PAGE FACILITIES
575 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-093
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-307.2
Bottom of paper towel dispenser is greater than 27" above finish floor and projects greater than 4" from wall.
Recommended Remediation:
Replace with semi-recessed or recessed paper towel dispenser or extend waste receptacle, which is below, outward so
maximum 4" projection beyond.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $180
Public Toilet Rooms Dispensers
Paper Towel
Measurement: 56 inches
404.2.9 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.4.1 Protrusion
Severity:C
Category Dispensers Precedence 8 Year 3 Cost with GC (30%): $234 Comment #: EXPO-094
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-606.5
Pipes are not insulated or covered in a way that protects against contact.
Recommended Remediation:
Install new insulation to cover pipes.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Lavatories (Sinks)
Exposed Pipes
Measurement: 1 count
606.5 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.24.6 Pipe Insulation
Severity:C
Category Lavatories (Sinks) Precedence 8 Year 3 Cost with GC (30%): $117
EXPO CENTER PAGE FACILITIES
576 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-095
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-213.3.1
There are a minimum of 6 total toilet compartments and number of ambulatory compartments is not equal to the number of accessible compartments.
Recommended Remediation:
Provide an ambulatory compartment with compliant grab bars and an outward swinging stall door. Floor/Area: Snack Bar and Restrooms Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms General Accessibility
Accessory Count
Measurement: 0 count
Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Ambulatory
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $117 Accessibility
Comment #: EXPO-096
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.1.2
The accessible stall door is not self-closing.
Recommended Remediation:
Replace self-closing hinges.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $250
Public Toilet Rooms Stall Door
Closer
Measurement: 1 count
404.2.8.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.10 Self-closing
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $325
EXPO CENTER PAGE FACILITIES
577 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-097
Facility: Expo Center
Deficiency:
Code References:
2018 CBC 11B-604.8.1.2, 2016 CBC 11B-404.2.7
The accessible stall door lock is not operable with one hand and/or requires tight grasping, pinching or twisting of the wrist to operate.
Recommended Remediation:
Replace stall door locks.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Stall Door
Hardware
Measurement: 1 count
309/404.2.7 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 Lock
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: EXPO-098
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.2.2
The accessible stall door does not provide pull handles on both sides of the door that are operable by one hand and do not require tight grasping, pinching or twisting of the wrist.
Recommended Remediation:
Add a pull handle (typically a u-pull handle) to the missing side of the door. Floor/Area: Snack Bar and Restrooms
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Stall Door
Hardware
Measurement: 1 count
309/404.2.7 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 U-Pull
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $117
EXPO CENTER PAGE FACILITIES
578 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-099
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-226.4
The baby changing table is not allowed in a stall.
Recommended Remediation:
Remove and relocate the baby changing station(s) outside of the accessible/ambulatory stall. Floor/Area: Snack Bar and Restrooms Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $600
Public Toilet Rooms Accessories
Baby Changing Table
Measurement: 1 count
226.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Location
Severity:C
Category Accessories Precedence 8 Year 3 Cost with GC (30%): $780 Comment #: EXPO-100
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.2
The center line of the toilet is either less than 17 inches or greater than 18 inches from the side wall or partition. The rear grab bar is aligned with misaligned toilet.
Recommended Remediation:
Move the toilet and relocate the rear grab bar to complinat location for new toilet location. Floor/Area: Snack Bar and Restrooms Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $3,200
Public Toilet Rooms Toilet Compartment
Water Closet (Toilet) (Stalls)
Measurement: 15.25 inches
604.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.16.2 Location
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $4,160 (Stalls)
EXPO CENTER PAGE FACILITIES
579 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-101
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.3.1
The water closet does not provide a clear space of 66 inches width in front of the toilet where dividers extend to the floor.
Recommended Remediation:
Reconfigure the space to provide proper clearances.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $2,500
Public Toilet Rooms Toilet Compartment
Clearance Space (Stalls)
Measurement: 56 inches
604.2/604.8 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.16.2 Width
Severity:C
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $3,250 (Stalls)
Comment #: EXPO-102
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.5.1
The side grab bar does not extend a minimum 24 inches from the front of the water closet. Additionally the flush valve is not located on the open side of the water closet.
Recommended Remediation:
Extend the side grab bar and attach to the stall partition. Remove and replace flush valve so that it is provided on the side furthest from the adjacent wall.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $1,000
Public Toilet Rooms Toilet Compartment
Side Grab Bar (Stalls)
Measurement: 15 inches
604.5 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16)(a)
Length
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $1,300 (Stalls)
EXPO CENTER PAGE FACILITIES
580 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-103
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-216.8.1
No geometric sign exists at the entrance to the public restroom to indicate the restroom gender.
Recommended Remediation:
Provide a sign with the appropriate geometric symbol.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 5 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Geometric Sign
Measurement: 1 count
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:D
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249 Comment #: EXPO-104
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-703.1
A tactile wall sign, identifying the public restroom, is not provided.
Recommended Remediation:
Install new tactile wall sign providing raised character text and Braille. Locate sign at latch side of door. Floor/Area: Snack Bar and Restrooms Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Tactile Sign
Measurement: 1 count
216.2/703.4.1&2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16(a))
General
Severity:C
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249
EXPO CENTER PAGE FACILITIES
581 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-153
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-602.7
There is no Hi/Lo drinking fountain nor is there pedestrian protection.
Recommended Remediation:
Provide an additional drinking fountain for standing persons.
Spout outlet shall be 38 inches minimum and 43 inches
maximum above the finished floor. Include pedestrian protection.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $11,861
Additional Access Drinking Fountains
Height
Measurement: 1 count
604.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.16.2 Hi/Lo
Severity:C
Category Drinking Fountains Precedence 8 Year 3 Cost with GC (30%): $15,419 Comment #: EXPO-105
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-307.2
Bottom of paper towel dispenser is greater than 27" above finish floor and projects greater than 4" from wall.
Recommended Remediation:
Replace with semi-recessed or recessed paper towel dispenser or extend waste receptacle, which is below, outward so
maximum 4" projection beyond.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $180
Public Toilet Rooms Dispensers
Paper Towel
Measurement: 52 inches
404.2.9 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.4.1 Protrusion
Severity:C
Category Dispensers Precedence 8 Year 3 Cost with GC (30%): $234
EXPO CENTER PAGE FACILITIES
582 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-106
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-603.3
The bottom edge of the reflecting surface of a mirror over the lavatory or countertop is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Lower mirror or install another mirror with bottom edge of reflective surface 35" maximum above finish floor. Floor/Area: Snack Bar and Restrooms Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $2,400
Public Toilet Rooms Room and Space
Mirror
Measurement: 51 inches
603.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $3,120 Comment #: EXPO-107
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-606.5
Pipes are not insulated or covered in a way that protects against contact.
Recommended Remediation:
Install insulation to cover pipes.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $180
Public Toilet Rooms Lavatories (Sinks)
Exposed Pipes
Measurement: 2 count
606.5 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.24.6 Pipe Insulation
Severity:C
Category Lavatories (Sinks) Precedence 8 Year 3 Cost with GC (30%): $234
EXPO CENTER PAGE FACILITIES
583 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-108
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-304.3
The space clear space in front of the urinal does not provide a clear floor turning space of 60 inches x 60 inches., or 30 inches by 48 inches clear floor space at the urinal.
Recommended Remediation:
Re-engineer restroom to provide appropriate clearance spaces.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $0
Public Toilet Rooms Room and Space
Urinal
Measurement: 36 inches
605.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.18 Clearance Space
Severity:C
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $0 Comment #: EXPO-109
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.1.2
The accessible stall door is not self-closing.
Recommended Remediation:
Replace self-closing hinges.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $250
Public Toilet Rooms Stall Door
Closer
Measurement: 1 count
404.2.8.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.10 Self-closing
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $325
EXPO CENTER PAGE FACILITIES
584 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-110
Facility: Expo Center
Deficiency:
Code References:
2019 CBC 11B-604.8.1.2, 2016 CBC 11B-404.2.7
The accessible stall door lock is not operable with one hand and/or requires tight grasping, pinching or twisting of the wrist to operate.
Recommended Remediation:
Replace stall door locks.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Stall Door
Hardware
Measurement: 1 count
309/404.2.7 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 Lock
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: EXPO-111
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-308.2.1
The top of the hook is greater than 48 inches above finished floor.
Recommended Remediation:
Relocate hook or add one at compliant height.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Accessories
Hook
Measurement: 67 inches
604.8.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Accessories Precedence 8 Year 3 Cost with GC (30%): $117
EXPO CENTER PAGE FACILITIES
585 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-112
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.3.1
The water closet does not provide a clear space of 60 inches width in front of the toilet.
Recommended Remediation:
Move partition to widen the accessible stall.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $2,500
Public Toilet Rooms Toilet Compartment
Clearance Space (Stalls)
Measurement: 58.5 inches
604.2/604.8 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.16.2 Width
Severity:C
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $3,250 (Stalls)
Comment #: EXPO-113
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.2
The stall clearance requires the movement of the stall partition which will create a noncompliant water closet location and grab bar length.
Recommended Remediation:
Move the toilet and relocate the rear grab bar to compliant location for new toilet location. Floor/Area: Snack Bar and Restrooms Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $3,200
Public Toilet Rooms Toilet Compartment
Water Closet (Toilet) (Stalls)
Measurement: 18 inches
604.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.16.2 Location
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $4,160 (Stalls)
EXPO CENTER PAGE FACILITIES
586 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-154
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-902.2
A minimum of 5% (with at least 1) of the total seating and standing space is not accessible for use of people in
wheelchairs.
Recommended Remediation:
Add an accessible table or work surface that provides compliant knee space. Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 2 Estimated Direct Cost: $1,300
Rooms and Spaces Seating
Dining and Work
Surfaces
Measurement: 0 count
404.2.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16)/4.30.1
General Accessibility
Severity:C
Category Seating Precedence 8 Year 3 Cost with GC (30%): $1,690 Comment #: EXPO-155
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-804.3.2
The height of the available counter surface is greater than the allowable 34 inches above the finished floor.
Recommended Remediation:
Provide a minimum of one accessible window. Counter is a protrusion as well above 27 inches AFF, add end caps for cane detection.
Floor/Area: Snack Bar and Restrooms
Room/Spot: Men’s Restroom
Priority: 2 Estimated Direct Cost: $4,304
Goods and Services Sales/Service Counters
Dimensions
Measurement: 41.5 inches
904.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.32.4/7.2
Height
Severity:C
Category Sales/Service Precedence 8 Year 3 Cost with GC (30%): $5,595 Counters
EXPO CENTER PAGE FACILITIES
587 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-114
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.4.2
For front approach to the pull side of the door there is less than 18 inches of maneuvering clearance beyond the latch side and/or less than 60 inches clear depth.
Recommended Remediation:
To maintain 60 inches of forward approach clearance on the pull side of door, adjust the adjacent partition and close off adjacent door.
Floor/Area: The Pavilion
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $8,816
Public Toilet Rooms Entrance
Clearance Space
Measurement: 41 inches
404.2.4.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.6 Pull Side Front
Approach
Severity:B
Category Entrance Precedence 8 Year 3 Cost with GC (30%): $11,461 Comment #: EXPO-115
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: The Pavilion
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Entrance
Door Operation
Measurement: 10 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Entrance Precedence 8 Year 3 Cost with GC (30%): $117
EXPO CENTER PAGE FACILITIES
588 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-116
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-603.3
The bottom edge of the reflecting surface of a mirror over the lavatory or countertop is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Lower mirror or install another mirror with bottom edge of reflective surface 35" maximum above finish floor. Floor/Area: The Pavilion Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $1,200
Public Toilet Rooms Room and Space
Mirror
Measurement: 44.5 inches
603.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $1,560 Comment #: EXPO-117
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-606.5
Pipes are not insulated or covered in a way that protects against contact.
Recommended Remediation:
Install new insulation to cover pipes.
Floor/Area: The Pavilion
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $180
Public Toilet Rooms Lavatories (Sinks)
Exposed Pipes
Measurement: 2 count
606.5 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.24.6 Pipe Insulation
Severity:C
Category Lavatories (Sinks) Precedence 8 Year 3 Cost with GC (30%): $234
EXPO CENTER PAGE FACILITIES
589 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-118
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-306.3.3 Exception 1
Knee space at a accessible lavatory, minimum 8 inches deep and 27 inches high from the floor to the bottom of the lavatory, is not provided.
Recommended Remediation:
Replace lavatory with one that provides compliant knee space.
Remove a section of the counter with 1 lavatory and make compliant.
Floor/Area: The Pavilion
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $5,988
Public Toilet Rooms Lavatories (Sinks)
Clear Knee Space
Measurement: 24 inches
305/306.2.3 Quantity: 10 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.24.3 Height
Severity:C
Category Lavatories (Sinks) Precedence 8 Year 3 Cost with GC (30%): $7,784 Comment #: EXPO-119
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-603.5
The operable parts of the unobstructed soap dispenser is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Adjust dispenser or provide additional accessible dispensers. this complies with federal ADA requirements. Floor/Area: The Pavilion Room/Spot: Women’s Restroom
Priority: 5 Estimated Direct Cost: $163
Public Toilet Rooms Dispensers
Soap Dispenser
Measurement: 46.5 inches
603 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.23.7 Height
Severity:D
Category Dispensers Precedence 8 Year 3 Cost with GC (30%): $212
EXPO CENTER PAGE FACILITIES
590 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-120
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.1.2
The accessible stall door is not self-closing.
Recommended Remediation:
Replace self-closing hinges.
Floor/Area: The Pavilion
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $250
Public Toilet Rooms Stall Door
Closer
Measurement: 1 count
404.2.8.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.10 Self-closing
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $325 Comment #: EXPO-121
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.2.2
The accessible stall door does not provide pull handles on both sides of the door that are operable by one hand and do not require tight grasping, pinching or twisting of the wrist.
Recommended Remediation:
Add a pull handle (typically a u-pull handle) to the missing side of the door. Floor/Area: The Pavilion
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Stall Door
Hardware
Measurement: 1 count
309/404.2.7 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 U-Pull
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $117
EXPO CENTER PAGE FACILITIES
591 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-122
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-226.4
The baby changing table is not allowed in a stall.
Recommended Remediation:
Remove and relocate the baby changing station(s) outside of the accessible/ambulatory stall. Floor/Area: The Pavilion
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $600
Public Toilet Rooms Accessories
Baby Changing Table
Measurement: 1 count
226.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Location
Severity:C
Category Accessories Precedence 8 Year 3 Cost with GC (30%): $780 Comment #: EXPO-123
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.5.2
The rear grab bar does not extend at least 24 inches from the center line of the toilet on the open side.
Recommended Remediation:
Remove and relocate the rear grab bar so that it extends a minimum 24 inches from the center line of the toilet on the open side.
Floor/Area: The Pavilion
Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $1,000
Public Toilet Rooms Toilet Compartment
Rear Grab Bar (Stalls)
Measurement: 22 inches
604.5 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16)(a)
Length
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $1,300 (Stalls)
EXPO CENTER PAGE FACILITIES
592 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-124
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-213.3.1
There are a minimum of 6 total toilet compartments and number of ambulatory compartments is not equal to the number of accessible compartments.
Recommended Remediation:
Provide an equal amount of ambulatory compartments with compliant grab bars and an outward swinging stall door. Floor/Area: The Pavilion Room/Spot: Women’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms General Accessibility
Accessory Count
Measurement: 0 count
Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Ambulatory
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $117 Accessibility
Comment #: EXPO-125
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.4.2
For front approach to the pull side of the door there is less than 18 inches of maneuvering clearance beyond the latch side and/or less than 60 inches clear depth. Additionally the barrier prevents minimum 44 inches circulation route width to accessible stall Recommended Remediation:
To maintain 60 inches of forward approach clearance on the pull side of door, adjust the adjacent partition and close off adjacent door.
Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $8,816
Public Toilet Rooms Entrance
Clearance Space
Measurement: 41 inches
404.2.4.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.6 Pull Side Front
Approach
Severity:A
Category Entrance Precedence 8 Year 3 Cost with GC (30%): $11,461
EXPO CENTER PAGE FACILITIES
593 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-126
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Entrance
Door Operation
Measurement: 9 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Entrance Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: EXPO-127
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.3.1
The water closet does not provide a clear space of 60 inches width in front of the toilet.
Recommended Remediation:
Relocate partition wall at Water Closet.
Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $2,500
Public Toilet Rooms Toilet Compartment
Clearance Space (Stalls)
Measurement: 57.75 inches
604.2/604.8 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.16.2 Width
Severity:C
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $3,250 (Stalls)
EXPO CENTER PAGE FACILITIES
594 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-128
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-306.3.3 Exception 1
Knee space at a accessible lavatory, minimum 8 inches deep and 27 inches high from the floor to the bottom of the lavatory, is not provided.
Recommended Remediation:
Replace lavatory with one that provides compliant knee space.
Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $5,988
Public Toilet Rooms Lavatories (Sinks)
Clear Knee Space
Measurement: 24.5 inches
305/306.2.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.24.3 Height
Severity:C
Category Lavatories (Sinks) Precedence 8 Year 3 Cost with GC (30%): $7,784 Comment #: EXPO-129
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-603.3
The bottom edge of the reflecting surface of a mirror over the lavatory or countertop is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Lower mirror or install another mirror with bottom edge of reflective surface 35" maximum above finish floor. Floor/Area: The Pavilion Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $1,200
Public Toilet Rooms Room and Space
Mirror
Measurement: 44.5 inches
603.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $1,560
EXPO CENTER PAGE FACILITIES
595 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-130
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-603.5
The operable parts of the unobstructed soap dispenser is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Adjust dispenser or provide additional accessible dispensers.
Meets federal ADA compliance. Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 5 Estimated Direct Cost: $163
Public Toilet Rooms Dispensers
Soap Dispenser
Measurement: 46.5 inches
603 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.23.7 Height
Severity:D
Category Dispensers Precedence 8 Year 3 Cost with GC (30%): $212 Comment #: EXPO-131
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.1.2
The accessible stall door is not self-closing.
Recommended Remediation:
Replace self-closing hinges.
Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $250
Public Toilet Rooms Stall Door
Closer
Measurement: 1 count
404.2.8.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.10 Self-closing
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $325
EXPO CENTER PAGE FACILITIES
596 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-132
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.8.2.2
The accessible stall door does not provide pull handles on both sides of the door that are operable by one hand and do not require tight grasping, pinching or twisting of the wrist.
Recommended Remediation:
Add a pull handle (typically a u-pull handle) to the missing side of the door. Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Stall Door
Hardware
Measurement: 1 count
309/404.2.7 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 U-Pull
Severity:C
Category Stall Door Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: EXPO-133
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-604.5.2
The rear grab bar does not extend at least 24 inches from the center line of the toilet on the open side.
Recommended Remediation:
Remove and relocate the rear grab bar so that it extends a minimum 24 inches from the center line of the toilet on the open side.
Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $1,000
Public Toilet Rooms Toilet Compartment
Rear Grab Bar (Stalls)
Measurement: 23 inches
604.5 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16)(a)
Length
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $1,300 (Stalls)
EXPO CENTER PAGE FACILITIES
597 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-134
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-609.3
The rear grab bar does not provide minimum allowable space of 1 1/2 inches between the bottom of the grab bar and any protruding objects below.
Recommended Remediation:
Relocate the grab bar.
Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $1,000
Public Toilet Rooms Toilet Compartment
Side Grab Bar (Stalls)
Measurement: 1 inches
609.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.17.6 Clearance
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $1,300 (Stalls)
Comment #: EXPO-135
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-605.2
The top rim of the accessible urinal is higher than the allowable 17 inches AFF.
Recommended Remediation:
Lower urinal so that the top rim is no higher than 17 inches.
Adjust one of the middle ones not the end one so that 30 inches by 48 inches clear space is provided in front of the accessible urinal.
Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 3 Estimated Direct Cost: $0
Public Toilet Rooms Room and Space
Urinal
Measurement: 17.5 inches
605.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.18 Height
Severity:C
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $0
EXPO CENTER PAGE FACILITIES
598 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-143
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 1011.4
There is no provided tactile exit sign at the doorway leading to a grade level exit.
Recommended Remediation:
Install one tactile exit sign, compliant with 2016 CBC 11B-703, where illuminated exit signs are provided. Floor/Area: The Pavilion Room/Spot: Men’s Restroom
Priority: 2 Estimated Direct Cost: $3,844
Rooms and Spaces Interior Doors
Signage
Measurement: 0 count
216.2/703.4.1&2 Quantity: 4 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16(a))
Tactile Exit Sign
Severity:A
Category Interior Doors Precedence 8 Year 3 Cost with GC (30%): $4,997 Comment #: EXPO-156
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-804.3.2
The height of the available counter surface is greater than the allowable 34 inches above the finished floor.
Recommended Remediation:
Provide lower counter section. Need to lower bar as a
transaction counter section Floor/Area: The Pavilion
Room/Spot: Men’s Restroom
Priority: 2 Estimated Direct Cost: $4,304
Goods and Services Sales/Service Counters
Dimensions
Measurement: 43 inches
904.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.32.4/7.2
Height
Severity:C
Category Sales/Service Precedence 8 Year 3 Cost with GC (30%): $5,595 Counters
EXPO CENTER PAGE FACILITIES
599 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-045
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path.
Recommended Remediation:
Provide cane detectable barriers all along the underside of the bleachers at angled support beams, or replace the existing sconces so they do not extend more than 4 inches from the wall.
Approximately 32 locations.
Floor/Area: Administration Building
Room/Spot: Exterior
Priority: 1 Estimated Direct Cost: $810
Site Elements Exterior Access Route
Protrusion
Measurement: 69 inches
N/A Quantity: 9 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Vertical Clearance
Severity:A
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $1,053 Route
Comment #: EXPO-136
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-213.2
The available space provided for the restrooms is not adequate clearance space.
Recommended Remediation:
The entire restroom needs to be demolished and an accessible restroom needs to be engineered in its place. A) Recommend making both restrooms gender neutral. B) Reconfigure 1 restroom to be accessible. C) Provide signage at non-accessible restroom directing to accessible restroom. D) Provide ISA on accessible restroom.
Floor/Area: Administration Building
Room/Spot: Exterior
Priority: 3 Estimated Direct Cost: $0
Public Toilet Rooms General Accessibility
Clearance Space
Measurement: 2 count
603.2.1 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.2.3 General
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $0 Accessibility
EXPO CENTER PAGE FACILITIES
600 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-054
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.7
The usable door hardware (lock and/or handle) requires operator to twist wrist, pinch, grasp tightly or in some other way impedes one handed operation.
Recommended Remediation:
Replace inaccessible knob with lever, loop or push hardware or add an automatic opener. Floor/Area: Administration Building Room/Spot: Lobby
Priority: 1 Estimated Direct Cost: $700
Entrance Doors, Doorways,
Door Operation Gates
Measurement: 2 count
309/404.2.7 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 Hardware
Severity:C
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $910 Gates
Comment #: EXPO-055
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: Administration Building
Room/Spot: Lobby
Priority: 2 Estimated Direct Cost: $90
Entrance Doors, Doorways,
Door Operation Gates
Measurement: 8 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $117 Gates
EXPO CENTER PAGE FACILITIES
601 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-061
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-804.3.2
The height of the available counter surface is greater than the allowable 34 inches above the finished floor.
Recommended Remediation:
Provide lower counter section.
Floor/Area: Administration Building
Room/Spot: Lobby
Priority: 2 Estimated Direct Cost: $4,304
Goods and Services Sales/Service Counters
Dimensions
Measurement: 47.75 inches
904.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.32.4/7.2
Height
Severity:C
Category Sales/Service Precedence 8 Year 3 Cost with GC (30%): $5,595 Counters
Comment #: EXPO-144
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-302.2
The edges of the carpet and/or mat is not securely attached to the floor to minimize tripping hazards.
Recommended Remediation:
Secure the carpet/mat at the edges to minimize tripping hazards.
Floor/Area: Administration Building
Room/Spot: Lobby
Priority: 2 Estimated Direct Cost: $180
Rooms and Spaces Interior Access Route
Carpets and Mats
Measurement: 2 count
302.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.3 Secure Floor
Attachment
Severity:C
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $234 Route
EXPO CENTER PAGE FACILITIES
602 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-056
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.7
The usable door hardware (lock and/or handle) requires operator to twist wrist, pinch, grasp tightly or in some other way impedes one handed operation.
Recommended Remediation:
Replace inaccessible knob with lever, loop or push hardware or add an automatic opener. Floor/Area: Administration Building Room/Spot: Lobby
Priority: 1 Estimated Direct Cost: $700
Entrance Doors, Doorways,
Door Operation Gates
Measurement: 2 count
309/404.2.7 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 Hardware
Severity:C
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $910 Gates
Comment #: EXPO-057
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.7
The usable door hardware (lock and/or handle) requires operator to twist wrist, pinch, grasp tightly or in some other way impedes one handed operation.
Recommended Remediation:
Replace inaccessible knob with lever, loop or push hardware or add an automatic opener. Floor/Area: Administration Building Room/Spot: Conference Room
Priority: 1 Estimated Direct Cost: $700
Entrance Doors, Doorways,
Door Operation Gates
Measurement: 2 count
309/404.2.7 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.9 Hardware
Severity:C
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $910 Gates
EXPO CENTER PAGE FACILITIES
603 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-157
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-804.3.2
The height of the available counter surface is greater than the allowable 34 inches above the finished floor.
Recommended Remediation:
Provide lower counter section. Insure that all available amenities are within the required reach ranges. Floor/Area: Administration Building Room/Spot: Conference Room
Priority: 2 Estimated Direct Cost: $4,304
Goods and Services Sales/Service Counters
Dimensions
Measurement: 41.5 inches
904.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.32.4/7.2
Height
Severity:C
Category Sales/Service Precedence 8 Year 3 Cost with GC (30%): $5,595 Counters
Comment #: EXPO-058
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: Administration Building
Room/Spot: Conference Room
Priority: 1 Estimated Direct Cost: $90
Site Elements Doors, Doorways,
Door Operation Gates
Measurement: 9 lbf
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Doors, Doorways, Precedence 6 Year 2 Cost with GC (30%): $117 Gates
EXPO CENTER PAGE FACILITIES
604 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-137
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-213.2
The available space provided for the restrooms is not adequate clearance space.
Recommended Remediation:
The entire restroom needs to be demolished and an accessible restroom needs to be engineered in its place. A) Recommend making both restrooms gender neutral. B) Reconfigure 1 restroom to be accessible. C) Provide signage at non-accessible restroom directing to accessible restroom. D) Provide ISA on accessible restroom.
Floor/Area: Administration Building
Room/Spot: Additional Restrooms
Priority: 3 Estimated Direct Cost: $0
Public Toilet Rooms General Accessibility
Clearance Space
Measurement: 1 count
603.2.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.2.3 General
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $0 Accessibility
Comment #: EXPO-138
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-213.2
The available space provided for the restrooms is not adequate clearance space.
Recommended Remediation:
The entire restroom needs to be demolished and an accessible restroom needs to be engineered in its place. A) Recommend making both restrooms gender neutral. B) Reconfigure 1 restroom to be accessible. C) Provide signage at non-accessible restroom directing to accessible restroom. D) Provide ISA on accessible restroom.
Floor/Area: Administration Building
Room/Spot: Additional Restrooms
Priority: 3 Estimated Direct Cost: $0
Public Toilet Rooms General Accessibility
Clearance Space
Measurement: 1 count
603.2.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.2.3 General
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $0 Accessibility
EXPO CENTER PAGE FACILITIES
605 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-139
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-213.2
The available space provided for the restrooms is not adequate clearance space.
Recommended Remediation:
The entire restroom needs to be demolished and an accessible restroom needs to be engineered in its place. A) Recommend making both restrooms gender neutral. B) Reconfigure 1 restroom to be accessible. C) Provide signage at non-accessible restroom directing to accessible restroom. D) Provide ISA on accessible restroom. General Accessibility. Change to single use accessible restroom. These cannot be made accessible. Make the exterior Restrooms accessible and provide directional signage to them.
Floor/Area: Administration Building
Room/Spot: Lobby
Priority: 3 Estimated Direct Cost: $0
Public Toilet Rooms General Accessibility
Clearance Space
Measurement: 1 count
603.2.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.2.3 General
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $0 Accessibility
Comment #: EXPO-140
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-213.2
The available space provided for the restrooms is not adequate clearance space.
Recommended Remediation:
The entire restroom needs to be demolished and an accessible restroom needs to be engineered in its place. A) Recommend making both restrooms gender neutral. B) Reconfigure 1 restroom to be accessible. C) Provide signage at non-accessible restroom directing to accessible restroom. D) Provide ISA on accessible restroom.
Floor/Area: Administration Building
Room/Spot: Lobby
Priority: 3 Estimated Direct Cost: $0
Public Toilet Rooms General Accessibility
Clearance Space
Measurement: 1 count
603.2.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.2.3 General
Severity:C
Category General Precedence 8 Year 3 Cost with GC (30%): $0 Accessibility
EXPO CENTER PAGE FACILITIES
606 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-145
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-307.2
Object/s located on the accessible circulation path that are less than 80 inches high and greater than 27 inches protrude more than 4 inches into the path.
Recommended Remediation:
Remove/Relocate object so that it does not obstruct the accessible circulation path, or provide a cane detectable element under the protruding object. Mirror Shelf
Floor/Area: Administration Building
Room/Spot: Lobby
Priority: 2 Estimated Direct Cost: $90
Rooms and Spaces Interior Access Route
Protrusion
Measurement: 60 inches
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Obstruction
Severity:A
Category Interior Access Precedence 8 Year 3 Cost with GC (30%): $117 Route
Comment #: EXPO-158
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-804.3.2
The height of the available counter surface is greater than the allowable 34 inches above the finished floor.
Recommended Remediation:
Provide lower counter section for a minimum of 60 inches length.
Floor/Area: Administration Building
Room/Spot: Avalon Room
Priority: 2 Estimated Direct Cost: $4,304
Goods and Services Sales/Service Counters
Dimensions
Measurement: 43.5 inches
904.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.32.4/7.2
Height
Severity:C
Category Sales/Service Precedence 8 Year 3 Cost with GC (30%): $5,595 Counters
EXPO CENTER PAGE FACILITIES
607 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-059
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: Administration Building
Room/Spot: Avalon Room
Priority: 2 Estimated Direct Cost: $180
Entrance Doors, Doorways,
Door Operation Gates
Measurement: 7 lbf
404.2.9 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $234 Gates
Comment #: EXPO-060
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.9.4
The force required to operate the door exceeds the allowable 5 lbf.
Recommended Remediation:
Adjust or replace the door closers.
Floor/Area: Administration Building
Room/Spot: Avalon Room
Priority: 2 Estimated Direct Cost: $180
Entrance Doors, Doorways,
Door Operation Gates
Measurement: 8 lbf
404.2.9 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.11 Opening Force
Severity:A
Category Doors, Doorways, Precedence 8 Year 3 Cost with GC (30%): $234 Gates
EXPO CENTER PAGE FACILITIES
608 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-146
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 1011.4
There is no provided tactile exit sign at the doorway leading to a grade level exit.
Recommended Remediation:
Install one tactile exit sign, compliant with 2016 CBC 11B-703, where illuminated exit signs are provided. Floor/Area: Administration Building Room/Spot: Avalon Room
Priority: 2 Estimated Direct Cost: $1,922
Rooms and Spaces Interior Doors
Signage
Measurement: 2 count
216.2/703.4.1&2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.1.3(16(a))
Tactile Exit Sign
Severity:A
Category Interior Doors Precedence 8 Year 3 Cost with GC (30%): $2,499 Comment #: EXPO-147
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-404.2.4.2
For front approach to the pull side of the door there is less than 18 inches of maneuvering clearance beyond the latch side and/or less than 60 inches clear depth.
Recommended Remediation:
Provide a sign that says “Employees Only”.
Floor/Area: Administration Building
Room/Spot: Avalon Room
Priority: 2 Estimated Direct Cost: $8,816
Rooms and Spaces Interior Doors
Clearance Space
Measurement: 1 count
404.2.4.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.6 Pull Side Front
Approach
Severity:C
Category Interior Doors Precedence 8 Year 3 Cost with GC (30%): $11,461
EXPO CENTER PAGE FACILITIES
609 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-141
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-216.3
No signage exists identifying the accessible exterior access route nor at junctions along the route that direct pedestrians to the accessible entrance of the facility.
Recommended Remediation:
Provide directional signage at junctions along the accessible route that direct pedestrians to the accessible entrance. Floor/Area: Administration Building Room/Spot: Avalon Room
Priority: 2 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Directional
Measurement: 1 count
216.8 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:C
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249 Comment #: EXPO-001
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Floor/Area: Administration Building Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $1,000
Site Elements Parking
Identification Signs
Measurement: 2 count
502.6 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $1,300
EXPO CENTER PAGE FACILITIES
610 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-002
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA symbol has deteriorated and no longer provides contrast with the ground surface.
Recommended Remediation:
Repaint the ISA. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133. Include a white border around ISA.
Floor/Area: Administration Building
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $800
Site Elements Parking
ISA Marking
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $1,040 Comment #: EXPO-003
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Administration Building
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 1 count
502.3.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $975
EXPO CENTER PAGE FACILITIES
611 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-004
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Administration Building
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 1 count
502.3.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $975 Comment #: EXPO-005
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.2
The accessible car stall is less than 108 inches (9 ft. or 2743 mm) wide.
Recommended Remediation:
Repaint the car stall markings to provide compliant width.
Dimensions to be measured to centerline. Does not include the gutter because of excessive slope.
Floor/Area: Administration Building
Room/Spot: Parking
Priority: 5 Estimated Direct Cost: $350
Site Elements Parking
Accessible Car Stall
Measurement: 98 inches
502.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Width
Severity:D
Category Parking Precedence 6 Year 2 Cost with GC (30%): $455
EXPO CENTER PAGE FACILITIES
612 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-006
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.2
The slope of the accessible parking spaces and aisles are steeper than the allowable 2.0%
Recommended Remediation:
Re-grade accessible surfaces so that the slope does not exceed
2.0%. Remove and regrade Accessible surfaces. Include new curb ramp.
Floor/Area: Administration Building
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $2,000
Site Elements Parking
Accessible Stall
Measurement: 2.5 % grade
502.4 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Slope
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $2,600 Comment #: EXPO-046
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-402.2
The running slope of the curb ramp exceeds the allowable 8.33% maximum grade and there is no upper turning space.
Recommended Remediation:
Remove and replace the existing curb ramp with a parallel ramp.
Include the gutter, detectable warning surfaces and create a new path to the admin building with compliant ramp features where required.
Floor/Area: Administration Building
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $15,300
Site Elements Exterior Access Route
Curb Ramp
Measurement: 1 count
405.2 Quantity: 340 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General Accessibility
Severity:B
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $19,890 Route
EXPO CENTER PAGE FACILITIES
613 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-007
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.6
Accessible spaces are not identified by signs that include the International Symbol of Accessibility.
Recommended Remediation:
Install signs at accessible stalls that include the International Symbol of Accessibility. Floor/Area: Avalon Room and Pavilion Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $1,000
Site Elements Parking
Signage
Measurement: 2 count
502.6 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Identification Signs
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $1,300 Comment #: EXPO-008
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA symbol has deteriorated and no longer provides contrast with the ground surface.
Recommended Remediation:
Repaint the ISA. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133. Include a white border around ISA.
Floor/Area: Avalon Room and Pavilion
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $800
Site Elements Parking
ISA Marking
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $1,040
EXPO CENTER PAGE FACILITIES
614 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-009
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines on asphalt within the border line of the access aisle faded.
Recommended Remediation:
For asphalt, recommend providing white hatched striping inside of a blue borderline. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Avalon Room and Pavilion
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Line: Asphalt
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $1,950 Comment #: EXPO-010
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.6.4.2
No blue stripe exists marking the accessible stall.
Recommended Remediation:
Paint a blue stripe on either side of the accessible stall along the entire length. Floor/Area: Avalon Room and Pavilion
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $700
Site Elements Parking
Accessible Car Stall
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Striping
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $910
EXPO CENTER PAGE FACILITIES
615 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-011
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.2
The slope of the accessible parking spaces and aisles are steeper than the allowable 2.0%
Recommended Remediation:
Re-grade accessible surfaces so that the slope does not exceed
2.0%. Restripe Floor/Area: Avalon Room and Pavilion
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $1,000
Site Elements Parking
Accessible Stall
Measurement: 3 % grade
502.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Slope
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $1,300 Comment #: EXPO-012
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The words "No Parking" in the access aisle have faded so that they are not contrasting with the ground surface.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Avalon Room and Pavilion
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Access Aisles
Measurement: 2 count
502.3.3 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $1,950
EXPO CENTER PAGE FACILITIES
616 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-013
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Floor/Area: Avalon Room and Pavilion Room/Spot: Parking
Priority: 5 Estimated Direct Cost: $1,000
Site Elements Parking
Identification Signs
Measurement: 2 count
502.6 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:D
Category Parking Precedence 6 Year 2 Cost with GC (30%): $1,300 Comment #: EXPO-014
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.2
The slope of the accessible parking spaces and aisles are steeper than the allowable 2.0%
Recommended Remediation:
Re-grade accessible surfaces so that the slope does not exceed
2.0%. Include striping, ISA, and access aisle. Floor/Area: Avalon Room and Pavilion Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $2,000
Site Elements Parking
Accessible Stall
Measurement: 2.8 % grade
502.4 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Slope
Severity:B
Category Parking Precedence 6 Year 2 Cost with GC (30%): $2,600
EXPO CENTER PAGE FACILITIES
617 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-015
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.6.2
The sign is not in front of the accessible stall. There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Move the sign and make it post mounted in front of the accessible parking space at compliant height.
Floor/Area: Avalon Room and Pavilion
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $500
Site Elements Parking
Identification Signs
Measurement: 1 count
502.6 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $650 Comment #: EXPO-016
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.2
The slope of the accessible parking spaces and aisles are steeper than the allowable 2.0%
Recommended Remediation:
Re-grade accessible surfaces so that the slope does not exceed
2.0%. Access aisle and stall, rest ripe and new ISA. Floor/Area: Avalon Room and Pavilion Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $1,000
Site Elements Parking
Accessible Stall
Measurement: 3 % grade
502.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Slope
Severity:B
Category Parking Precedence 6 Year 2 Cost with GC (30%): $1,300
EXPO CENTER PAGE FACILITIES
618 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-017
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.6.2, 2016 CBC 11B-502.6.3
There is no sign indicating the minimum fine for parking in accessible stall without required placard. Bottom of the lowest sign should be 60 inches minimum above parking paving.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Make sure it is compliant height. Floor/Area: Avalon Room and Pavilion Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $500
Site Elements Parking
Identification Signs
Measurement: 1 count
502.6 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $650 Comment #: EXPO-018
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.2
The slope of the accessible parking spaces and aisles are steeper than the allowable 2.0%
Recommended Remediation:
Re-grade accessible surfaces so that the slope does not exceed
2.0%. Access aisle, new striping and ISA. Floor/Area: Avalon Room and Pavilion Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $1,000
Site Elements Parking
Accessible Stall
Measurement: 2.8 % grade
502.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Slope
Severity:B
Category Parking Precedence 6 Year 2 Cost with GC (30%): $1,300
EXPO CENTER PAGE FACILITIES
619 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-019
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-208.2.4
One access space in every six access spaces (or portion of 6) is not van accessible.
Recommended Remediation:
Reconfigure spaces by repainting lines. Include signage indicating van accessible spaces. Floor/Area: Avalon Room and Pavilion Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $350
Site Elements Parking
Van Accessibility
Measurement: 0 count
208.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Count
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $455 Comment #: EXPO-020
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.7
There is no path of travel from the accessible parking to the facility entrance.
Recommended Remediation:
Create compliant path of travel to all accessible parking space include leveling cross walk and parking area. Create a path through planter near cross walk and stripe access aisle from all stalls to it without passing behind other vehicle spaces.
Floor/Area: Avalon Room and Pavilion
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Path of Travel
Measurement: 1 count
206.2.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $975
EXPO CENTER PAGE FACILITIES
620 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-047
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-406.5.7
The cross slope exceeds the allowable 1:48 (2.0%) grade.
Recommended Remediation:
Remove and dispose of materials and replace and re-grade to provide an accessible curb ramp. Create compliant parallel curb ramp with truncated domes.
Floor/Area: Avalon Room and Pavilion
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $600
Site Elements Exterior Access Route
Curb Ramp
Measurement: 4.8 % grade
405.2 Quantity: 40 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Cross Slope
Severity:B
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $780 Route
Comment #: EXPO-048
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.4.1
Warning stripes are not provided at all treads and/or the upper approach.
Recommended Remediation:
Add contrasting stripes between 2 and 4 inches wide across the entire width of each tread and/or the upper approach. Floor/Area: Avalon Room and Pavilion Room/Spot: Parking
Priority: 5 Estimated Direct Cost: $504
Site Elements Exterior Access Route
Stairs
Measurement: 0 count
N/A Quantity: 84 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Warning Stripes
Severity:D
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $655 Route
EXPO CENTER PAGE FACILITIES
621 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-049
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-210.1
There is no accessible route to view the Pavilion.
Recommended Remediation:
Engineer an accessible route between the accessible parking and the facility entrance. Floor/Area: Avalon Room and Pavilion Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $90
Site Elements Exterior Access Route
General Access
Measurement: 1 count
504 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Stairs
Severity:A
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $117 Route
Comment #: EXPO-050
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-303.2
There exists a vertical displacement greater than 0.5 inches.
Recommended Remediation:
Install metal ramps at each barn opening. Maintain a 1:48 slope maximum in any direction. Floor/Area: Barns
Room/Spot: All Barns
Priority: 1 Estimated Direct Cost: $0
Site Elements Exterior Access Route
Surface Continuity
Measurement: 4 inches
303.2/303.3 Quantity: 16 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.5.2 Vertical Displacement
Severity:A
Category Exterior Access Precedence 6 Year 3 Cost with GC (30%): $0 Route
EXPO CENTER PAGE FACILITIES
622 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-021
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.2
The slope of the accessible parking spaces and aisles are steeper than the allowable 2.0%
Recommended Remediation:
Re-grade accessible surfaces so that the slope does not exceed
2.0%. Include access aisles and ISA and compliant striping. 9 stalls and access aisle including middle pathway.
Floor/Area: Grand Arena
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $9,000
Site Elements Parking
Accessible Stall
Measurement: 4.5 % grade
502.4 Quantity: 9 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Slope
Severity:B
Category Parking Precedence 6 Year 2 Cost with GC (30%): $11,700 Comment #: EXPO-022
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.2
The slope of the accessible parking spaces and aisles are steeper than the allowable 2.0%
Recommended Remediation:
Re-grade accessible surfaces so that the slope does not exceed
2.0%. Include access aisles and ISA and compliant striping. Floor/Area: Grand Arena Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $4,000
Site Elements Parking
Accessible Stall
Measurement: 4.7 % grade
502.4 Quantity: 4 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Slope
Severity:B
Category Parking Precedence 6 Year 2 Cost with GC (30%): $5,200
EXPO CENTER PAGE FACILITIES
623 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-023
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-504.2
The slope of the accessible parking spaces and aisles are steeper than the allowable 2.0%
Recommended Remediation:
Re-grade accessible surfaces so that the slope does not exceed
2.0%. Include access aisles and ISA and compliant striping. Floor/Area: Grand Arena Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $4,000
Site Elements Parking
Accessible Stall
Measurement: 4.8 % grade
502.4 Quantity: 4 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Slope
Severity:B
Category Parking Precedence 6 Year 2 Cost with GC (30%): $5,200 Comment #: EXPO-024
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-208.2
There are not enough accessible parking spaces designated as per Table 11B-208.2.
Recommended Remediation:
14 spaces counted (See Site Plan). Regrade replace and
restripe including ISA blue stall striping and access aisle and a connection to a path of travel towards the entrance that does not go behind other vehicles.
Floor/Area: Grand Arena
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $350
Site Elements Parking
Space Count
Measurement: 0 count
208.2 Quantity: 126 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $455
EXPO CENTER PAGE FACILITIES
624 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-025
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-208.2
There are not enough accessible parking spaces designated as per Table 11B-208.2.
Recommended Remediation:
Restripe and re sign including blue stall striping ISA and access aisles. Create path of travel in front of vehicle spaces to entrance. And signs. When you move spaces due to access aisle installation make sure new spaces are compliant with CBC 11B.
Floor/Area: Grand Arena
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $350
Site Elements Parking
Space Count
Measurement: 0 count
208.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $455 Comment #: EXPO-026
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.7
There is no path of travel from the accessible parking to the facility entrance.
Recommended Remediation:
Compliant curb ramps (approx. 8) needed at each access aisle.
And a compliant concrete route to the facility entrance (ticket checker). Route to be placed in front of spaces because they cannot go behind other parked vehicles per CBC 11B.
Floor/Area: Grand Arena
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $67,500
Site Elements Parking
Path of Travel
Measurement: 8 count
206.2.2 Quantity: 1500 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $87,750
EXPO CENTER PAGE FACILITIES
625 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-027
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-208.2.4
One access space in every six access spaces (or portion of 6) is not van accessible.
Recommended Remediation:
Reconfigure spaces by repainting lines. Include signage indicating van accessible spaces. 48 total accessible parking spaces existing. Of which only 5 are van accessible. Minimum 8 are required.
Floor/Area: Grand Arena
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $2,250
Site Elements Parking
Van Accessibility
Measurement: 0 count
208.2 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Count
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $2,925 Comment #: EXPO-028
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-208.2
There are not enough accessible parking spaces designated as per Table 11B-208.2.
Recommended Remediation:
Reengineer the parking lot to provide compliant accessible parking. There are 750 total spaces in the lot. 50 accessible spaces are required.
Floor/Area: Grand Arena
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $17,500
Site Elements Parking
Space Count
Measurement: 50 count
208.2 Quantity: 50 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $22,750
EXPO CENTER PAGE FACILITIES
626 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: EXPO-029
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-208.2
There is no accessible route that doesn’t go behind other vehicles to the facility. There are no access aisles or compliant signage at the correct sign height.
Recommended Remediation:
Full striping and access aisles needed for 9 spaces. According to the pamphlet provided by the Expo Center, there are 402 parking spaces in this lot including dirt lot. A minimum of 9 places are needed. For 9 spaces 2 must be compliant van stalls. Resign the spaces also with compliant sign height, van accessible signs and minimum fine signs.
Floor/Area: Pavilion
Room/Spot: Parking
Priority: 1 Estimated Direct Cost: $3,150
Site Elements Parking
Accessible Parking
Measurement: 0 count
502.3.3 Quantity: 9 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:C
Category Parking Precedence 6 Year 2 Cost with GC (30%): $4,095 Comment #: EXPO-030
Facility: Expo Center
Deficiency:
Code References:
2016 CBC 11B-502.8
The tow sign is not reflective and/or the text of the sign is not compliant.
Recommended Remediation:
Install proper tow-away signage.
Floor/Area: Facility Entrance
Room/Spot: Parking
Priority: 5 Estimated Direct Cost: $500
Site Elements Parking
Tow Away Signage
Measurement: 1 count
208.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
General
Severity:D
Category Parking Precedence 6 Year 2 Cost with GC (30%): $650
EXPO CENTER PAGE FACILITIES
627 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
FIRE STATION
FIRE STATION PAGE FACILITIES
628 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Site Plan:
FIRE STATION PAGE FACILITIES
629 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Floor Plan:
FIRE STATION PAGE FACILITIES
630 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
FACILITY: FIRE STATION
Facility Description:
Facility was constructed in the year .
Facility Address:
This facility is used for the following programs:
1995
Fire Station
17056 Gale St.
FIRE STATION PAGE FACILITIES
631 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: FS-10
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-703.7.2.6.3, 2016 CBC 11B-703.7.2.6
The geometric symbols do not contrast with eachother.
Additionally, the center of the geometric sign exceeds the allowable 60 inches AFF.
Recommended Remediation:
Install a new geometric sign in which the triangle contrasts with the circle and the ircle contrasts with the door. Install with the center of the sign at a height between 58 inches and 60 inches AFF.
Floor/Area: Lobby
Room/Spot: Unisex Restroom
Priority: 5 Estimated Direct Cost: $961
Public Toilet Rooms Signs
Geometric Sign
Measurement: 66 inches
N/A Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast and Height
Severity:D
Category Signs Precedence 8 Year 3 Cost with GC (30%): $1,249 Comment #: FS-11
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-304.3.2, 2016 CBC 11B-404.2.4.1
The width of the turning space provided is less than the allowable 60 inches minimum. Additionally, 18 inches minimum latch side pull clearance at the door is not provided.
Recommended Remediation:
Remove the cabinet to provide compliant turn around space and latch side clearance. Floor/Area: Lobby
Room/Spot: Unisex Restroom
Priority: 2 Estimated Direct Cost: $0
Public Toilet Rooms Room and Space
Clearance Space
Measurement: 48 inches
604.2/604.8 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.16.2 Width
Severity:B
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $0
FIRE STATION PAGE FACILITIES
632 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: FS-12
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-604.2
The center line of the toilet is either less than 17 inches or greater than 18 inches from the side wall or partition. The rear grab bar is aligned with misaligned toilet.
Recommended Remediation:
Move the toilet and relocate the rear grab bar to compliant location for new toilet location. Floor/Area: Lobby
Room/Spot: Unisex Restroom
Priority: 3 Estimated Direct Cost: $3,200
Public Toilet Rooms Toilet Compartment
Water Closet (Toilet) (Stalls)
Measurement: 20.5 inches
604.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.16.2 Location
Severity:C
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $4,160 (Stalls)
Comment #: FS-13
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-609.3
A minimum of 12 inch clearance above the grab bar is not provided.
Recommended Remediation:
Relocate the seat cover dispenser so that it does not obstruct the clear space around the grab bar. Floor/Area: Lobby
Room/Spot: Unisex Restroom
Priority: 3 Estimated Direct Cost: $2,000
Public Toilet Rooms Toilet Compartment
Side Grab Bar (Stalls)
Measurement: 1.5 inches
609.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.17.6 Clearance
Severity:B
Category Toilet Compartment Precedence 8 Year 3 Cost with GC (30%): $2,600 (Stalls)
FIRE STATION PAGE FACILITIES
633 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: FS-14
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-603.3
The bottom edge of the reflecting surface of a mirror over the lavatory or countertop is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Lower mirror or install another mirror with bottom edge of reflective surface 35" maximum above finish floor. Floor/Area: Lobby Room/Spot: Unisex Restroom
Priority: 3 Estimated Direct Cost: $1,200
Public Toilet Rooms Room and Space
Mirror
Measurement: 41 inches
603 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Height
Severity:C
Category Room and Space Precedence 8 Year 3 Cost with GC (30%): $1,560 Comment #: FS-15
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-603.5
The operable parts of the unobstructed soap dispenser is higher than the allowable 40 inches above the floor.
Recommended Remediation:
Adjust dispenser or provide additional accessible dispensers.
Floor/Area: Lobby
Room/Spot: Unisex Restroom
Priority: 3 Estimated Direct Cost: $163
Public Toilet Rooms Dispensers
Soap Dispenser
Measurement: 54.5 inches
603 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.23.7 Height
Severity:C
Category Dispensers Precedence 8 Year 3 Cost with GC (30%): $212
FIRE STATION PAGE FACILITIES
634 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: FS-16
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-606.5
The pipe insulation at the lavatory has become loose.
Recommended Remediation:
Lift insulation coverings up and secure in place. Any securement shall be protected from skin contact Floor/Area: Lobby
Room/Spot: Unisex Restroom
Priority: 3 Estimated Direct Cost: $90
Public Toilet Rooms Lavatories (Sinks)
Exposed Pipes
Measurement: 1 count
606.5 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.24.6 Pipe Insulation
Severity:C
Category Lavatories (Sinks) Precedence 8 Year 3 Cost with GC (30%): $117 Comment #: FS-09
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-804.3.2
The height of the available counter surface is greater than the allowable 34 inches above the finished floor.
Recommended Remediation:
Provide lower counter section.
Floor/Area: Lobby
Room/Spot: Counter
Priority: 2 Estimated Direct Cost: $4,304
Goods and Services Sales/Service Counters
Dimensions
Measurement: 1 count
904.4 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.32.4/7.2
Height
Severity:C
Category Sales/Service Precedence 8 Year 3 Cost with GC (30%): $5,595 Counters
FIRE STATION PAGE FACILITIES
635 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: FS-17
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-404.2.4.1
The front approach, pull door does not provide the minimum 18 inches maneuvering clearance beyond the latch side of the door.
Recommended Remediation:
Remove the chair to provide the required maneuvering
clearance. Floor/Area: Lobby
Room/Spot: Entrance
Priority: 2 Estimated Direct Cost: $8,816
Goods and Services Entrance
Doorway
Measurement: 1 count
404.2.4.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
4.13.6 Maneuvering Clearance
Severity:C
Category Entrance Precedence 8 Year 3 Cost with GC (30%): $11,461 Comment #: FS-07
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-402.2
The running slope, parallel to the path of travel, exceeds the allowable 5% grade.
Recommended Remediation:
Add ramp features such as edge protection, level landings, and handrails. Floor/Area: Path of Travel
Room/Spot: Ramp to Guest Parking
Priority: 1 Estimated Direct Cost: $270
Site Elements Exterior Access Route
Slope
Measurement: 7.3 % grade
405.2 Quantity: 18 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Running Slope
Severity:B
Category Exterior Access Precedence 3 Year 1 Cost with GC (30%): $351 Route
FIRE STATION PAGE FACILITIES
636 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: FS-01
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-502.3.1
The access aisle does not maintain a clear width of 5 feet (60 inches) level surface due to the curb ramp encroachment.
Recommended Remediation:
The built curb ramp cannot extend into the access aisle. Solution is to demolish and make a parallel curb ramp at the sidewalk. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $5,000
Site Elements Parking
Curb Ramp
Measurement: 0 feet
Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Curb Ramp
Encroachment
Severity:C
Category Parking Precedence 3 Year 1 Cost with GC (30%): $6,500 Comment #: FS-02
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The access aisle does not provide the words "No Parking" in minimum 12 inch (305 mm) high lettering visible from the adjacent vehicular way.
Recommended Remediation:
Mark access aisles 'No Parking' or repaint existing markings to provide contrast compliant with local requirements. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 1 count
502.3.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
"No Parking"
Severity:C
Category Parking Precedence 3 Year 1 Cost with GC (30%): $975
FIRE STATION PAGE FACILITIES
637 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: FS-03
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The hatched lines inside the access aisle do not contrast with the surface.
Recommended Remediation:
Repaint the access aisle markings with a blue border and blue hatched lines to contrast with the cement. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR
35.133.
Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisles
Measurement: 1 count
502.3.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Hatched Lines:
Concrete
Severity:C
Category Parking Precedence 3 Year 1 Cost with GC (30%): $975 Comment #: FS-04
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-502.3.3
The ISA symbol has deteriorated and no longer provides contrast with the ground surface.
Recommended Remediation:
Repaint the ISA. Accessible stalls and access aisles must be maintained per 11B-108, and ADA CFR 35.133. Floor/Area: Parking Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $400
Site Elements Parking
ISA Marking
Measurement: 1 count
502.3.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Contrast
Severity:C
Category Parking Precedence 3 Year 1 Cost with GC (30%): $520
FIRE STATION PAGE FACILITIES
638 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: FS-05
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-502.6.2
There is no sign indicating the minimum fine for parking in accessible stall without required placard.
Recommended Remediation:
Install sign below the sign with the ISA symbol that states "Minimum Fine $250". Floor/Area: Parking
Room/Spot: Accessible Parking
Priority: 1 Estimated Direct Cost: $500
Site Elements Parking
Identification Signs
Measurement: 1 count
502.6 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Minimum Fine
Severity:C
Category Parking Precedence 3 Year 1 Cost with GC (30%): $650 Comment #: FS-08
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-403.3
The running slope, parallel to the path of travel, exceeds the allowable 5% grade.
Recommended Remediation:
Remove and dispose of noncompliant route materials and
replace and re-grade so that the running slope does not exceed 5%.
Floor/Area: Parking
Room/Spot: Site Arrival Point
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Exterior Access Route
Slope
Measurement: 10.7 % grade
405.2 Quantity: 100 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Running Slope
Severity:B
Category Exterior Access Precedence 3 Year 1 Cost with GC (30%): $1,950 Route
FIRE STATION PAGE FACILITIES
639 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: FS-06
Facility: Fire Station
Deficiency:
Code References:
2016 CBC 11B-502.8.2
The verbiage on the "tow-away" sign is not compliant with 2016 CBC 11B-502.8.2.
Recommended Remediation:
Remove and replace the current sign with a Caltrans R-100B sign, and provide reclaim vehicle information as a permanent part of the sign. An additional sign shall be posted either; 1) in a conspicuous place at each entrance to an off-street parking facility or 2) immediately adjacent to on-site accessible parking and visible from each parking space.
Floor/Area: Parking
Room/Spot: Lot Entrance
Priority: 1 Estimated Direct Cost: $500
Site Elements Parking
Tow Away Signage
Measurement: 1 count
208.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
N/A
Verbiage
Severity:C
Category Parking Precedence 3 Year 1 Cost with GC (30%): $650
FIRE STATION PAGE FACILITIES
640 Submittal: November 1, 2024
Barrier ID: AX394461
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.8
Barrier Detail
The accessible door with door closer has a sweep period of less than 5 seconds from 90 degrees to a position 12 degrees from latch.
Location Description Captains Office Door Leading To Apparatus Flloor Observed Sep 28, 2023 by [email protected] Site Conditions
The closing speed is 3.44 seconds from 90 degrees to a position 12 degrees from latch.
Resolution
Adjust closer or remove and replace closer to ensure that the door has a closure time of at least 5 seconds within 12 degrees of the latch. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Priority 1
Quantity
1 EA
Unit Cost
457.50
Total Cost
$ 458
Photos for Barrier ID: AX394461
641 Submittal: November 1, 2024
Barrier ID: AX394463
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.4; Table 404.2.4.1
Barrier Detail
The pull side of the accessible door does not have the required maneuvering clearances.
Location Description Captains Office Door Leading To Apparatus Flloor Observed Sep 28, 2023 by [email protected] Site Conditions
For an approach from the front on the pull side the maneuvering clearance has a slope of 3.1%.
Resolution
Redesign to provide the required maneuvering clearance at the pull side of the door. The required depth of the maneuvering clearance is X" minimum. The required side clearance is Y" minimum on the latch/hinge side of the door. Maneuvering clearance shall extend the full width of the doorway and the required latch side or hinge side clearance. Floor or ground space within the required maneuvering clearance shall be maximum 1:48 (2.08%) slope. Changes in level are not permitted.
Priority 1
Quantity
1 EA
Unit Cost
1,562.50
Total Cost
$ 1,563
642 Submittal: November 1, 2024
Photos for Barrier ID: AX394463
643 Submittal: November 1, 2024
Barrier ID: AX394456
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.4; Table 404.2.4.1
Barrier Detail
The push side of the accessible door does not have the required maneuvering clearances.
Location Description Captains Office Door Leading To Exit Observed Sep 28, 2023 by [email protected] Site Conditions
For an approach from the front on the push side the side clearance is 11". The door has a latch and closure.
Resolution
Redesign to provide the required maneuvering clearance on the push side the door. The required depth of the maneuvering clearance is 48" minimum. The required side clearance is 12" minimum on the latch side of the door. Maneuvering clearance shall extend the full width of the doorway and the required latch side clearance.
Floor or ground space within the required maneuvering clearance shall be maximum 1:48 (2.08%) slope.
Changes in level are not permitted.
Priority 1
Quantity
1 EA
Unit Cost
1,562.50
Total Cost
$ 1,563
Photos for Barrier ID: AX394456
644 Submittal: November 1, 2024
Barrier ID: AX394458
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.4; Table 404.2.4.1
Barrier Detail
The pull side of the accessible door does not have the required maneuvering clearances.
Location Description Captains Office Door Leading To Exit Observed Sep 28, 2023 by [email protected] Site Conditions
For an approach from the front on the pull side the side clearance is 4" due to the location of the furniture.
Resolution
Relocate the furniture to provide the required maneuvering clearance at the pull side of the door. The required depth of the maneuvering clearance is 60" minimum. The required side clearance is 18" minimum on the latch side of the door. Maneuvering clearance shall extend the full width of the doorway and the required latch side clearance. Floor or ground space within the required maneuvering clearance shall be maximum 1:48 (2.08%) slope. Changes in level are not permitted.
Priority 1
Quantity
1 EA
Unit Cost
125.00
Total Cost
$ 125
Photos for Barrier ID: AX394458
645 Submittal: November 1, 2024
Barrier ID: AX394492
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.4; Table 404.2.4.1
Barrier Detail
The push side of the accessible door does not have the required maneuvering clearances.
Location Description East Region Administration Door Leading to Apparatus Fllor Observed Sep 28, 2023 by [email protected] Site Conditions
For an approach from the front on the push side the side clearance is 3" due to the location of the cabinet. The door has a latch and closure.
Resolution
Relocate the cabinet to provide the required maneuvering clearance on the push side the door. The required depth of the maneuvering clearance is 48" minimum. The required side clearance is 12" minimum on the latch side of the door. Maneuvering clearance shall extend the full width of the doorway and the required latch side clearance. Floor or ground space within the required maneuvering clearance shall be maximum 1:48 (2.08%) slope. Changes in level are not permitted.
Priority 1
Quantity
1 EA
Unit Cost
125.00
Total Cost
$ 125
Photos for Barrier ID: AX394492
646 Submittal: November 1, 2024
Barrier ID: AX394494
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.4; Table 404.2.4.1
Barrier Detail
The push side of the accessible door does not have the required maneuvering clearances.
Location Description East Region Administration Door Leading to Apparatus Fllor Observed Sep 28, 2023 by [email protected] Site Conditions
For an approach from the front on the push side the side clearance is 13" and the maneuvering depth is 43-1/2".
The door has a latch and closure.
Resolution
Redesign to provide the required maneuvering clearance on the push side the door. The required depth of the maneuvering clearance is 48" minimum. The required side clearance is 12" minimum on the latch side of the door. Maneuvering clearance shall extend the full width of the doorway and the required latch side clearance.
Floor or ground space within the required maneuvering clearance shall be maximum 1:48 (2.08%) slope.
Changes in level are not permitted.
Priority 1
Quantity
1 EA
Unit Cost
1,562.50
Total Cost
$ 1,563
647 Submittal: November 1, 2024
Photos for Barrier ID: AX394494
648 Submittal: November 1, 2024
Barrier ID: AX394482
City of Industry Fire Station 118 INTERIOR
Assembly Entrance to Building
Type Building Entrance-Door
ADA Standard 404.2.4; Table 404.2.4.1
Barrier Detail
The pull side of the accessible door does not have the required maneuvering clearances.
Location Description East Region Administration Entry Door Observed Sep 28, 2023 by [email protected] Site Conditions
For an approach from the front on the pull side the side clearance is 7-1/2" due to the location of the furniture and the maneuvering depth is 23-1/2" do to the location of the hand sanitizer stand.
Resolution
Relocate the furniture and hand sanitizer stand to provide the required maneuvering clearance at the pull side of the door. The required depth of the maneuvering clearance is 60" minimum. The required side clearance is 18" minimum on the latch side of the door. Maneuvering clearance shall extend the full width of the doorway and the required latch side clearance. Floor or ground space within the required maneuvering clearance shall be maximum 1:48 (2.08%) slope. Changes in level are not permitted.
Priority 1
Quantity
1 EA
Unit Cost
125.00
Total Cost
$ 125
649 Submittal: November 1, 2024
Photos for Barrier ID: AX394482
650 Submittal: November 1, 2024
Barrier ID: AX394453
City of Industry Fire Station 118 INTERIOR
Assembly Entrance to Building
Type Building Entrance-Door
ADA Standard CBD Chap 11B-404.2.9
Barrier Detail
CALIFORNIA: The non-fire, hinged accessible exterior door takes more than 5#s of pressure to operate.
Location Description Fire Station Business Entrance
Observed Sep 28, 2023 by [email protected] Site Conditions The opening force is 8 pounds.
Resolution
Adjust the closer or replace with an exterior non-fire door that requires no more 5 pounds of force for pushing or pulling the door open. This barrier must be removed in conjunction with barrier ID 394454. The cost of this barrier removal is covered under ID 394454 and therefore, the cost of this ID is shown as $0. The force for pushing or pulling open a door or gate other than fire doors shall be as follows: 1. Interior hinged doors and gates: 5 pounds (22.2 N) maximum. 2. Sliding or folding doors: 5 pounds (22.2 N) maximum. These forces do not apply to the force required to retract latch bolts or disengage other devices that hold the door or gate in a closed position.
Note: Fire doors shall have a minimum opening force allowable by the appropriate administrative authority.
Priority 1
Quantity
1 EA
Unit Cost
0.00 Total Cost
$ 0
Photos for Barrier ID: AX394453
651 Submittal: November 1, 2024
Barrier ID: AX394454
City of Industry Fire Station 118 INTERIOR
Assembly Entrance to Building
Type Building Entrance-Door
ADA Standard 404.2.8
Barrier Detail
The accessible door with door closer has a sweep period of less than 5 seconds from 90 degrees to a position 12 degrees from latch.
Location Description Fire Station Business Entrance
Observed Sep 28, 2023 by [email protected] Site Conditions
The closing speed is 2.20 seconds from 90 degrees to a position 12 degrees from latch.
Resolution
Adjust closer or remove and replace closer to ensure that the door has a closure time of at least 5 seconds within 12 degrees of the latch. This barrier must be removed in conjunction with barrier ID 394453. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Priority 1
Quantity
1 EA
Unit Cost
457.50
Total Cost
$ 458
Photos for Barrier ID: AX394454
652 Submittal: November 1, 2024
Barrier ID: AX394465
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.4; Table 404.2.4.1
Barrier Detail
The pull side of the accessible door does not have the required maneuvering clearances.
Location Description Restroom Vestibule Door
Observed Sep 28, 2023 by [email protected] Site Conditions For an approach from the front on the pull side the side clearance is 10-1/4".
Resolution
Redesign to provide the required maneuvering clearance at the pull side of the door. The required depth of the maneuvering clearance is 60" minimum. The required side clearance is 18" minimum on the latch side of the door. Maneuvering clearance shall extend the full width of the doorway and the required latch side clearance.
Floor or ground space within the required maneuvering clearance shall be maximum 1:48 (2.08%) slope.
Changes in level are not permitted.
Priority 1
Quantity
1 EA
Unit Cost
1,562.50
Total Cost
$ 1,563
Photos for Barrier ID: AX394465
653 Submittal: November 1, 2024
Barrier ID: AX394467
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.8
Barrier Detail
The accessible door with door closer has a sweep period of less than 5 seconds from 90 degrees to a position 12 degrees from latch.
Location Description Restroom Vestibule Door
Observed Sep 28, 2023 by [email protected] Site Conditions
The closing speed is 1.86 seconds from 90 degrees to a position 12 degrees from latch.
Resolution
Adjust closer or remove and replace closer to ensure that the door has a closure time of at least 5 seconds within 12 degrees of the latch. Door closers and gate closers shall be adjusted so that from an open position of 90 degrees, the time required to move the door to a position of 12 degrees from the latch is 5 seconds minimum.
Priority 1
Quantity
1 EA
Unit Cost
457.50
Total Cost
$ 458
Photos for Barrier ID: AX394467
654 Submittal: November 1, 2024
Barrier ID: AX394469
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.4; Table 404.2.4.1
Barrier Detail
The push side of the accessible door does not have the required maneuvering clearances.
Location Description Restroom Vestibule Door
Observed Sep 28, 2023 by [email protected] Site Conditions
For an approach form the front on the push side the side clearance is 10-1/2" if the restroom on the latch side has the door closed. The door has a latch and closure.
Resolution
Remove the door closer or redesign to provide the required maneuvering clearance on the push side the door.
The required depth of the maneuvering clearance is 48" minimum. The required side clearance is 12" minimum on the latch side of the door. Maneuvering clearance shall extend the full width of the doorway and the required latch side clearance. Floor or ground space within the required maneuvering clearance shall be maximum 1:48 (2.08%) slope. Changes in level are not permitted.
Priority 1
Quantity
1 EA
Unit Cost
1,562.50
Total Cost
$ 1,563
Photos for Barrier ID: AX394469
655 Submittal: November 1, 2024
Barrier ID: AX394459
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.10
Barrier Detail
The surface of the swinging door within 10 inches of the finish floor or ground for the full width of the door on the push side is not smooth.
Location Description Captains Office Door Leading To Apparatus Flloor Observed Sep 28, 2023 by [email protected] Site Conditions
The bottom 10" of the door on the push side is not smooth due to the location of the door stop on the door.
Resolution
Modify or replace the door to provide a smooth surface on the door within 10 inches of the finish floor or ground for the full width of the door on the push side. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other and be free of sharp or abrasive edges. Cavities created by added kick plates shall be capped.Swinging door and gate surfaces within 10 inches of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate.
Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other. Cavities created by added kick plates shall be capped. [EXCEPTIONS: 1. Sliding doors shall not be required to comply. 2. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal shall not be required to meet the 10 inch bottom smooth surface height requirement. 3. Doors and gates that do not extend to within 10 inches of the finish floor or ground shall not be required to comply. 4. Existing doors and gates without smooth surfaces within 10 inches of the finish floor or ground shall not be required to provide smooth surfaces provided that if added kick plates are installed, cavities created by such kick plates are capped.] Priority 2
Quantity
1 EA
Unit Cost
250.00
Total Cost
$ 250
656 Submittal: November 1, 2024
Photos for Barrier ID: AX394459
657 Submittal: November 1, 2024
Barrier ID: AX394460
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.11
Barrier Detail The bottom of the door vision light is higher than 43" and less than 66".
Location Description Captains Office Door Leading To Apparatus Flloor Observed Sep 28, 2023 by [email protected] Site Conditions The bottom of the vision light is 61" above the floor.
Resolution
Provide a door with the bottom of at least one of the glazing panels located 43" maximum above the finish floor or grade. At least one of the glazing panels shall be located for viewing through the panels, if the panel is designed for viewing. [EXCEPTION: Vision lights with the lowest part more than 66" from the finish floor or ground are not required to comply.]
Priority 2
Quantity
1 EA
Unit Cost
3,250.00
Total Cost
$ 3,250
Photos for Barrier ID: AX394460
658 Submittal: November 1, 2024
Barrier ID: AX394457
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.10
Barrier Detail
The surface of the swinging door within 10 inches of the finish floor or ground for the full width of the door on the push side is not smooth.
Location Description Captains Office Door Leading To Exit Observed Sep 28, 2023 by [email protected] Site Conditions
The bottom 10" of the door on the push side is not smooth due to the location of the door stop on the door.
Resolution
Modify or replace the door to provide a smooth surface on the door within 10 inches of the finish floor or ground for the full width of the door on the push side. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other and be free of sharp or abrasive edges. Cavities created by added kick plates shall be capped.Swinging door and gate surfaces within 10 inches of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate.
Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other. Cavities created by added kick plates shall be capped. [EXCEPTIONS: 1. Sliding doors shall not be required to comply. 2. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal shall not be required to meet the 10 inch bottom smooth surface height requirement. 3. Doors and gates that do not extend to within 10 inches of the finish floor or ground shall not be required to comply. 4. Existing doors and gates without smooth surfaces within 10 inches of the finish floor or ground shall not be required to provide smooth surfaces provided that if added kick plates are installed, cavities created by such kick plates are capped.] Priority 2
Quantity
1 EA
Unit Cost
250.00
Total Cost
$ 250
659 Submittal: November 1, 2024
Photos for Barrier ID: AX394457
660 Submittal: November 1, 2024
Barrier ID: AX394493
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.11
Barrier Detail The bottom of the door vision light is higher than 43" and less than 66".
Location Description East Region Administration Door Leading to Apparatus Fllor Observed Sep 28, 2023 by [email protected] Site Conditions The bottom of the vision light is 61" above the floor.
Resolution
Provide a door with the bottom of at least one of the glazing panels located 43" maximum above the finish floor or grade. At least one of the glazing panels shall be located for viewing through the panels, if the panel is designed for viewing. [EXCEPTION: Vision lights with the lowest part more than 66" from the finish floor or ground are not required to comply.]
Priority 2
Quantity
1 EA
Unit Cost
3,250.00
Total Cost
$ 3,250
Photos for Barrier ID: AX394493
661 Submittal: November 1, 2024
Barrier ID: AX394481
City of Industry Fire Station 118 INTERIOR
Assembly Entrance to Building
Type Building Entrance-Door
ADA Standard 404.2.10
Barrier Detail
The surface of the door within 10 inches of the finish floor or ground for the full width of the door on the push side is not smooth.
Location Description East Region Administration Entry Door Observed Sep 28, 2023 by [email protected] Site Conditions The smooth surface on the bottom of the door on the push side is 9" high.
Resolution
Modify or replace the door to provide a surface of the door within 10 inches of the finish floor or ground for the full width of the door on the push side that is smooth. Swinging door and gate surfaces within 10 inches of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other. Cavities created by added kick plates shall be capped. [EXCEPTIONS: 1. Sliding doors shall not be required to comply. 2. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal shall not be required to meet the 10 inch bottom smooth surface height requirement. 3. Doors and gates that do not extend to within 10 inches of the finish floor or ground shall not be required to comply. 4. Existing doors and gates without smooth surfaces within 10 inches of the finish floor or ground shall not be required to provide smooth surfaces provided that if added kick plates are installed, cavities created by such kick plates are capped,] Priority 2
Quantity
1 EA
Unit Cost
500.00
Total Cost
$ 500
662 Submittal: November 1, 2024
Photos for Barrier ID: AX394481
663 Submittal: November 1, 2024
Barrier ID: AX394490
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Reach Range
ADA Standard 308, 309
Barrier Detail
Items requiring an obstructed side reach motion are higher than 48" maximum where the obstruction depth is 10" maximum, or higher than 46" maximum where the obstruction depth is between 10" and 24" and/or lower than 15" minimum height above finish floor.
Location Description East Region Administration Kichenette Observed Sep 28, 2023 by [email protected] Site Conditions
The highest operable part of the microwave oven is 59" above the floor an requires reaching over a 36-1/2" tall cabinet.
Resolution
Remove and lower to a compliant reach range. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48" maximum and the low side reach shall be 15" minimum above the finish floor or ground. [EXCEPTION: An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10" maximum.] Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34" maximum and the depth of the obstruction shall be 24" maximum. The high side reach shall be 48" maximum for a reach depth of 10" maximum. Where the reach depth exceeds 10", the high side reach shall be 46" maximum for a reach depth of 24" maximum. [ADVISORY for Children's Forward or Side Reach Ranges: High reach (maximum): 36" for ages 3 to 4; 40" for ages 5 to 8; and 44" for ages 9 to 12. Low reach (minimum): 20" for ages 3 to 4; 18" for ages 5 to 8; and 16" for ages 9 to 12.] Priority 2
Quantity
1 EA
Unit Cost
625.00
Total Cost
$ 625
664 Submittal: November 1, 2024
Photos for Barrier ID: AX394490
665 Submittal: November 1, 2024
Barrier ID: AX394491
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Reach Range
ADA Standard 308, 309
Barrier Detail
Items requiring an obstructed side reach motion are higher than 48" maximum where the obstruction depth is 10" maximum, or higher than 46" maximum where the obstruction depth is between 10" and 24" and/or lower than 15" minimum height above finish floor.
Location Description East Region Administration Kichenette Observed Sep 28, 2023 by [email protected] Site Conditions
The toaster oven, toaster, and coffee machine require reaching over a 36-1/2" tall counter with reach depths from 12" to 13-1/2".
Resolution
Remove and lower to a compliant reach range. Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed, the high side reach shall be 48" maximum and the low side reach shall be 15" minimum above the finish floor or ground. [EXCEPTION: An obstruction shall be permitted between the clear floor or ground space and the element where the depth of the obstruction is 10" maximum.] Where a clear floor or ground space allows a parallel approach to an element and the high side reach is over an obstruction, the height of the obstruction shall be 34" maximum and the depth of the obstruction shall be 24" maximum. The high side reach shall be 48" maximum for a reach depth of 10" maximum. Where the reach depth exceeds 10", the high side reach shall be 46" maximum for a reach depth of 24" maximum. [ADVISORY for Children's Forward or Side Reach Ranges: High reach (maximum): 36" for ages 3 to 4; 40" for ages 5 to 8; and 44" for ages 9 to 12. Low reach (minimum): 20" for ages 3 to 4; 18" for ages 5 to 8; and 16" for ages 9 to 12.] Priority 2
Quantity
3 EA
Unit Cost
250.00
Total Cost
$ 750
666 Submittal: November 1, 2024
Photos for Barrier ID: AX394491
667 Submittal: November 1, 2024
Barrier ID: AX394489
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Sink
ADA Standard 306.2 and 606.3
Barrier Detail
The sink rim is higher than 34", and does not have knee and toe clearance (does not apply to mop basins, utility sinks, or bar sinks).
Location Description East Region Administration Kichenette Observed Sep 28, 2023 by [email protected] Site Conditions
The rim of the sink is 36-1/2" above the floor and knee and toe clearance is not provided due to the location of the cabinet under the sink.
Resolution
Relocate sink to compliant height with knee and toe clearances. Lavatories and sinks shall be installed with the front of the higher of the rim or counter surface 34" maximum above the finish floor or ground. Knee Clearance:
Space under an element between 9" and 27" above the finish floor or ground shall be considered knee clearance. Knee clearance shall extend 25" maximum under an element at 9" above the finish floor or ground.
Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11" deep minimum at 9" above the finish floor or ground, and 8" deep minimum at 27" above the finish floor or ground. Between 9" and 27" above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1" in depth for each 6" in height. Knee clearance shall be 30" wide minimum. Toe Clearance: Space under an element between the finish floor or ground and 9" above the finish floor or ground shall be considered toe clearance. Toe clearance shall extend 25" maximum under an element. Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17" minimum under the element. Space extending greater than 6" beyond the available knee clearance at 9" above the finish floor or ground shall not be considered toe clearance. Toe clearance shall be 30" wide minimum.
Priority 2
Quantity
1 EA
Unit Cost
900.00
Total Cost
$ 900
668 Submittal: November 1, 2024
Photos for Barrier ID: AX394489
669 Submittal: November 1, 2024
Barrier ID: AX394483
City of Industry Fire Station 118 INTERIOR
Assembly Common Areas
Type Service Counter
ADA Standard CBC Chap 11B-306, 904.4
Barrier Detail
CALIFORNIA: The service counter does not have 36" long section that is 34" maximum above finished floor that is oriented for a parallel approach, or the service counter does not have a 36" long section that is 34" maximum above the finished floor, with knee and toe clearance oriented for a forward approach.
Location Description East Region Administration Lobby
Observed Sep 28, 2023 by [email protected] Site Conditions The top of the service counter is 44" above the floor.
Resolution
Provide either a compliant parallel or a compliant forward approach to the counter. For a parallel approach, a portion of service counter must be 36" minimum long and 34" maximum above finished floor. Clear space of minimum 30" wide and minimum 48" long shall be located adjacent to the compliant portion of the counter, and oriented for a parallel approach, with the 48" dimension adjacent to the compliant portion. [EXCEPTION: Where the provided counter surface is less then 36" long, the entire counter surface shall be 34" high maximum above the finish floor.] For a forward approach, a portion of the service counter must be 36" long and 34" high maximum, with knee and toe clearance. Knee and toe clearance shall be provided for a forward approach. Clear floor space minimum 30" wide and minimum 48" long shall be provided on the compliant portion of the counter, and oriented for a forward approach. Clear space at the counter shall be maximum 2.08% in all directions and a firm and stable surface. Knee clearance shall be the space under an element between 9" and 27" above the finish floor or ground. Knee clearance shall extend 25" maximum under an element at 9" above the finish floor or ground. Where knee clearance is required under an element as part of a clear floor space, the knee clearance shall be 11" deep minimum at 9" above the finish floor or ground, and 8" deep minimum at 27" above the finish floor or ground. Between 9" and 27" above the finish floor or ground, the knee clearance shall be permitted to reduce at a rate of 1" in depth for each 6" in height. Knee clearance shall be 30" wide minimum. Space under an element between the finish floor or ground and 9" above the finish floor or ground shall be considered toe clearance. Toe clearance shall extend 25" maximum under an element. Where toe clearance is required at an element as part of a clear floor space, the toe clearance shall extend 17" minimum under the element .Space extending greater than 6" beyond the available knee clearance at 9" above the finish floor or ground shall not be considered toe clearance. Toe clearance shall be 30" wide minimum.
Priority 2
Quantity
3 LF
Unit Cost
751.88
Total Cost
$ 2,256
670 Submittal: November 1, 2024
Photos for Barrier ID: AX394483
671 Submittal: November 1, 2024
Barrier ID: AX394455
City of Industry Fire Station 118 INTERIOR
Assembly Entrance to Building
Type Building Entrance-Door
ADA Standard 404.2.10
Barrier Detail
The surface of the door within 10 inches of the finish floor or ground for the full width of the door on the push side is not smooth.
Location Description Fire Station Business Entrance
Observed Sep 28, 2023 by [email protected] Site Conditions The smooth surface on the bottom of the door on the push side is 9" high.
Resolution
Modify or replace the door to provide a surface of the door within 10 inches of the finish floor or ground for the full width of the door on the push side that is smooth. Swinging door and gate surfaces within 10 inches of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other. Cavities created by added kick plates shall be capped. [EXCEPTIONS: 1. Sliding doors shall not be required to comply. 2. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal shall not be required to meet the 10 inch bottom smooth surface height requirement. 3. Doors and gates that do not extend to within 10 inches of the finish floor or ground shall not be required to comply. 4. Existing doors and gates without smooth surfaces within 10 inches of the finish floor or ground shall not be required to provide smooth surfaces provided that if added kick plates are installed, cavities created by such kick plates are capped,] Priority 2
Quantity
1 EA
Unit Cost
500.00
Total Cost
$ 500
672 Submittal: November 1, 2024
Photos for Barrier ID: AX394455
673 Submittal: November 1, 2024
Barrier ID: AX394466
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.11
Barrier Detail The bottom of the door vision light is higher than 43" and less than 66".
Location Description Restroom Vestibule Door
Observed Sep 28, 2023 by [email protected] Site Conditions The bottom of the vision light is 61" above the floor.
Resolution
Provide a door with the bottom of at least one of the glazing panels located 43" maximum above the finish floor or grade. At least one of the glazing panels shall be located for viewing through the panels, if the panel is designed for viewing. [EXCEPTION: Vision lights with the lowest part more than 66" from the finish floor or ground are not required to comply.]
Priority 2
Quantity
1 EA
Unit Cost
3,250.00
Total Cost
$ 3,250
Photos for Barrier ID: AX394466
674 Submittal: November 1, 2024
Barrier ID: AX394468
City of Industry Fire Station 118 INTERIOR
Assembly Interior Access Route
Type Door
ADA Standard 404.2.10
Barrier Detail
The surface of the swinging door within 10 inches of the finish floor or ground for the full width of the door on the push side is not smooth.
Location Description Restroom Vestibule Door
Observed Sep 28, 2023 by [email protected] Site Conditions
The bottom 10" of the door is not smooth due to the location of the door stop on the door.
Resolution
Modify or replace the door to provide a smooth surface on the door within 10 inches of the finish floor or ground for the full width of the door on the push side. Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other and be free of sharp or abrasive edges. Cavities created by added kick plates shall be capped.Swinging door and gate surfaces within 10 inches of the finish floor or ground measured vertically shall have a smooth surface on the push side extending the full width of the door or gate.
Parts creating horizontal or vertical joints in these surfaces shall be within 1/16 inch of the same plane as the other. Cavities created by added kick plates shall be capped. [EXCEPTIONS: 1. Sliding doors shall not be required to comply. 2. Tempered glass doors without stiles and having a bottom rail or shoe with the top leading edge tapered at 60 degrees minimum from the horizontal shall not be required to meet the 10 inch bottom smooth surface height requirement. 3. Doors and gates that do not extend to within 10 inches of the finish floor or ground shall not be required to comply. 4. Existing doors and gates without smooth surfaces within 10 inches of the finish floor or ground shall not be required to provide smooth surfaces provided that if added kick plates are installed, cavities created by such kick plates are capped.] Priority 2
Quantity
1 EA
Unit Cost
250.00
Total Cost
$ 250
675 Submittal: November 1, 2024
Photos for Barrier ID: AX394468
676 Submittal: November 1, 2024
Barrier ID: AX394488
City of Industry Fire Station 118 INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Lavatory
ADA Standard CBC Chap 11B-213, 306, 606
Barrier Detail
CALIFORNIA: The lavatory does not have the required knee and toe clearance.
Location Description East Region Administration Lobby Restroom Observed Sep 28, 2023 by [email protected] Site Conditions The knee clearance at the lavatory is 6" deep at 27" above the floor.
Resolution
Provide at least 10% but no fewer than one lavatory with compliant knee and toe clearance. The lavatory shall maintain the maximum allowable height of 34" to the rim of the sink. The maximum allowable exterior bowl depth is 6-1/2". A compliant clear floor space of minimum 30" wide centered on the lavatory and minimum 48" deep, positioned for a forward approach, shall be provided. Space under an element between 9" and 29" above the finish floor or ground shall be considered knee clearance and shall comply. Knee clearance shall be 11" deep minimum at 9" above the finish floor or ground, and 8" deep minimum at 27" above the finish floor. The bottom of the front of the lavatory shall be minimum 29" above the finish floor. Knee clearance reduction is not allowed. Toe clearance shall be minimum 25" horizontal depth between the finish floor and 9" AFF. Knee and toe clearance shall be 30" wide minimum and centered on the lavatory. A compliant clear floor space, positioned for a forward approach, and compliant knee and toe clearance shall be provided. [EXCEPTIONS: 1. Toe clearance shall extend 19" maximum under lavatories 2. A lavatory in a toilet room or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to provide knee and toe clearance. 3. In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the fixture; (b) the finish floor extends under the cabinetry; and (c) the walls behind and surrounding the cabinetry are finished. 4. A knee clearance of 24" minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31" maximum above the finish floor or ground. 5. A parallel approach complying with 305 shall be permitted to lavatories and sinks used primarily by children 5 years and younger.6. The dip of the overflow shall not be considered in determining knee and toe clearances. 7. No more than one bowl of a multi-bowl sink shall be required to provide knee and toe clearance.]
Priority 3
Quantity
1 EA
Unit Cost
900.00
Total Cost
$ 900
677 Submittal: November 1, 2024
Photos for Barrier ID: AX394488
678 Submittal: November 1, 2024
Barrier ID: AX394487
City of Industry Fire Station 118 INTERIOR
Assembly Restroom
Type Restroom/Bathroom - Water Closet
ADA Standard 604.5.2
Barrier Detail The rear grab bar at the water closet is not compliant.
Location Description East Region Administration Lobby Restroom Observed Sep 28, 2023 by [email protected] Site Conditions
The rear grab bar extends 19-1/2" from the centerline of the water closet on the open side.
Resolution
Remove and install a compliant rear grab bar. The rear wall grab bar shall be 36" long minimum and extend from the centerline of the water closet 12" minimum on the closed side and 24" minimum on the open side. [EXCEPTIONS: 1. The rear grab bar shall be permitted to be 24" long minimum, centered on the water closet, where wall space does not permit a length of 36" minimum due to the location of a recessed fixture adjacent to the water closet. 2. Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall be permitted to be split or shifted to the open side of the toilet area.] Grab bars shall be installed in a horizontal position, 33" minimum and 36" maximum above the finish floor measured to the top of the gripping surface, except that at water closets for children's use, grab bars shall be installed in a horizontal position 18" minimum and 27" maximum above the finish floor measured to the top of the gripping surface. A continuous grab bar is allowable in lieu of rear and side grab bars. [ADVISORY: It is advisable, but not required, to use the specifications for children where children are the primary users of the restroom. Guidance in applying the specifications for children according to the age group served reflects the differences in the size, stature, and reach ranges of children ages 3 to 12. The specifications chosen should correspond to the age of the primary user group. The specifications of one age group should be applied consistently in the installation of a water closet and related elements. Water Closet Centerline: Ages 3 and 4- 12"; Ages 5 through 8- 12" to 15"; Ages 9 through 12- 15" to 18". Toilet Seat Height: Ages 3 and 4- 11" to 12"; Ages 5 through 8- 12" to 15"; Ages 9 through 12- 15" to 17". Grab Bar Height: Ages 3 and 4- 18" to 20"; Ages 5 through 8- 20" to 25"; Ages 9 through 12- 25" to 27"; Dispenser Height: Ages 3 and 4- 14"; Ages 5 through 8- 14" to 17"; Ages 9 through 12- 17" to 19"].
Priority 3
Quantity
1 EA
Unit Cost
443.75
Total Cost
$ 444
679 Submittal: November 1, 2024
Photos for Barrier ID: AX394487
680 Submittal: November 1, 2024
Barrier ID: AX394484
City of Industry Fire Station 118 INTERIOR
Assembly Restroom
Type Restroom/Bathroom-Water Closet
ADA Standard CBC Chap 11B- 604.3.1 and 3.2
Barrier Detail CALIFORNIA- The water closet does not have the required clear floor space.
Location Description East Region Administration Lobby Restroom Observed Sep 28, 2023 by [email protected] Site Conditions
The clear space at the water closet is 56-1/4" measured perpendicular from the side wall to the lavatory, 42" to the trash can and 43-1/2" to the furniture. The maneuvering clearance in front of the water closet is 35" deep to the furniture
Resolution
Redesign to ensure that the water closet has the minimum required clear floor space. The water closet shall be positioned with a wall or partition to the rear and to one side. Clearance around a water closet shall be 60" minimum measured perpendicular from the side wall and 56" minimum measured perpendicular from the rear wall. A minimum 60" wide and 48' deep maneuvering space shall be provided in front of the water closet. [Exception: In residential dwelling units required to be mobility accessible, maneuvering space in front of the water closet shall be a minimum 60" wide and 36" deep.] The centerline of the water closet shall be 17" minimum to 18" maximum from the side wall or partition, Water closets shall be arranged for a left-hand or right-hand approach, with the flush on the open side. The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space. No other fixtures or obstructions shall be located within the required water closet clearance. [Exception: In residential dwelling units, a lavatory shall be permitted on the rear wall 18" minimum from the water closet centerline where the clearance at the water closet is 66" minimum measured perpendicular from the rear wall.] [ADVISORY: It is advisable, but not required, to use the specifications for children where children are the primary users of the restroom. Guidance in applying the specifications for children according to the age group served reflects the differences in the size, stature, and reach ranges of children ages 3 to 12. The specifications chosen should correspond to the age of the primary user group. The specifications of one age group should be applied consistently in the installation of a water closet and related elements. Water Closet Centerline: Ages 3 and 4- 12"; Ages 5 through 8- 12" to 15"; Ages 9 through 12- 15" to 18". Toilet Seat Height: Ages 3 and 4- 11" to 12"; Ages 5 through 8- 12" to 15"; Ages 9 through 12- 15" to 17". Grab Bar Height: Ages 3 and 4- 18" to 20"; Ages 5 through 8- 20" to 25"; Ages 9 through 12- 25" to 27"; Dispenser Height: Ages 3 and 4- 14"; Ages 5 through 8- 14" to 17"; Ages 9 through 12- 17" to 19"].
Priority 3
Quantity
1 EA
Unit Cost
1,375.00
Total Cost
$ 1,375
681 Submittal: November 1, 2024
Photos for Barrier ID: AX394484
682 Submittal: November 1, 2024
683 Submittal: November 1, 2024
Barrier ID: AX394486
City of Industry Fire Station 118 INTERIOR
Assembly Restroom
Type Restroom/Bathroom-Water Closet
ADA Standard CBC Chap 11B- 604.5.1
Barrier Detail CALIFORNIA- The side grab bar at the water closet is not compliant.
Location Description East Region Administration Lobby Restroom Observed Sep 28, 2023 by [email protected] Site Conditions The side grab bar extends 52" from the rear wall.
Resolution
Ensure that the water closet has a compliant side grab bar. The side wall grab bar shall be 42 inches long minimum, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall with the front end positioned 24 inches minimum in front of the water closet. The water closet shall be positioned with a wall or partition to the rear and to one side for installation of a side grab bar on the side wall closest to the water closet. An L-shaped grab bar meeting the dimensions requirements for the side grab bar and rear grab bar is permitted. Grab bars should be installed in a horizontal position 33 inches to 36 inches maximum above the finish floor measured to the top of the gripping surface. [ADVISORY: It is advisable, but not required, to use the specifications for children where children are the primary users of the restroom. Guidance in applying the specifications for children according to the age group served reflects the differences in the size, stature, and reach ranges of children ages 3 to 12. The specifications chosen should correspond to the age of the primary user group. The specifications of one age group should be applied consistently in the installation of a water closet and related elements. Grab Bar Height: Ages 3 and 4- 18 inches to 20 inches; Ages 5 through 8- 20 inches to 25 inches; Ages 9 through 12- 25 inches to 27 inches.} Priority 3
Quantity
1 EA
Unit Cost
1,375.00
Total Cost
$ 1,375
684 Submittal: November 1, 2024
Photos for Barrier ID: AX394486
685 Submittal: November 1, 2024
Barrier ID: AX398919
City of Industry Fire Station 118 INTERIOR
Assembly Restroom
Type Restroom/Bathroom-Water Closet
ADA Standard 609.3
Barrier Detail
The space between the grab bar and projecting objects above the grab bar is less than 12" minimum.
Location Description East Region Administration Lobby Restroom Observed Sep 28, 2023 by [email protected] Site Conditions
The seat cover dispenser is less than 12" above the side grab bar and the clear space is obstructed by the water closet.
Resolution
Move the projecting object above the grab bar to 12" minimum from the top of the gripping surface of the grab bar. [EXCEPTION: The space between grab bars and shower controls, shower fittings, and other grab bars above shall be permitted to be 1-1/2" minimum.]
Priority 3
Quantity
1 EA
Unit Cost
125.00
Total Cost
$ 125
686 Submittal: November 1, 2024
Photos for Barrier ID: AX398919
687 Submittal: November 1, 2024
Barrier ID: AX394464
City of Industry Fire Station 118 INTERIOR
Assembly Restroom
Type Restroom/Bathroom-Signage
ADA Standard 703.7
Barrier Detail
Where not all restrooms in the facility are accessible, the provided signage at accessible restrooms does not have the International Symbol of Accessibility.
Location Description Restroom Vestibule Door
Observed Sep 28, 2023 by [email protected] Site Conditions Directional signage is not provided to the accessible restrooms.
Resolution
Mount compliant signage on the wall at the latch side of the restroom door at a compliant height. All signs for accessible restrooms, including directional signs indicating the restroom location, shall comply with the requirement for the International Symbol of Accessibility, where not all restrooms in the facility are accessible.
Signage shall include raised letters and Braille, either one sign with both visual and tactile characters, or two separate signs, one with visual, and one with tactile characters, shall be provided. Tactile characters on signs shall be located 48" minimum above the finish floor or ground surface, measured from the baseline of the lowest tactile character and 60" maximum above the finish floor or ground surface, measured from the baseline of the highest tactile character. Accessible restrooms shall have signs with the International Symbol of Accessibility.
Where a tactile sign is provided at a door, the sign shall be located alongside the door at the latch side. Where a tactile sign is provided at double doors with one active leaf, the sign shall be located on the inactive leaf. Where a tactile sign is provided at double doors with two active leafs, the sign shall be located to the right of the right hand door. Where there is no wall space at the latch side of a single door or at the right side of double doors, signs shall be located on the nearest adjacent wall. Signs containing tactile characters shall be located so that a clear floor space of 18" minimum by 18" minimum, centered on the tactile characters, is provided beyond the arc of any door swing between the closed position and 45 degree open position. [EXCEPTION: Signs with tactile characters shall be permitted on the push side of doors with closers and without hold-open devices.] Raised characters shall be as follows: Depth: Raised characters shall be 1/32" minimum above their background. Case:
Characters shall be uppercase. Style: Characters shall be sans serif. Characters shall not be italic, oblique, script, highly decorative, or of other unusual forms. Character Proportions: Characters shall be selected from fonts where the width of the uppercase letter "O" is 55 % minimum and 110 % maximum of the height of the uppercase letter "I". Character Height: Character height measured vertically from the baseline of the character shall be 5/8" minimum and 2" maximum based on the height of the uppercase letter "I". [EXCEPTION: Where separate raised and visual characters with the same information are provided, raised character height shall be permitted to be 1/2" minimum.] The visual characters of the sign shall be installed at minimum 40" above finish floor.
Priority 3
Quantity
1 EA
Unit Cost
68.70 Total Cost
$ 69
688 Submittal: November 1, 2024
Photos for Barrier ID: AX394464
689 Submittal: November 1, 2024
Barrier ID: AX394473
City of Industry Fire Station 118 INTERIOR
Assembly Restroom
Type Restroom/Bathroom
ADA Standard CBC Chap 11B-213, 306, 603, 604, 606, 608, 609, 610 Barrier Detail The entire restroom is not compliant due to limited room dimensions.
Location Description Single User Restrooms
Observed Sep 28, 2023 by [email protected] Site Conditions
The restroom is not accessible all 4 single user restrooms are the same. The turning space is 51" maximum, the clear space at the water closet measured perpendicular from the side wall to the vanity, the clearance in front of the water closet is 43-1/4", the shower is 34-1/4" deep with a 6" step, the lavatory does not have knee and toe clearance, the door does not have compliant maneuvering clearance, grab bars are not provided at the water closet or shower, the accessories are not compliant, the signage is not compliant, and the floor has a 2.7% slope. 690 Submittal: November 1, 2024
Resolution
691 Submittal: November 1, 2024
Redesign the single user restroom to allow for a larger restroom with compliant dimensions for all restroom fixtures, including an accessible route into the restroom and clear space at fixtures. This barrier must be removed in conjunction with barrier ID 394480. Provide compliant restroom fixtures. The water closet shall be positioned with a wall or partition to the rear and to one side. Clearance around a water closet shall be 60" minimum measured perpendicular from the side wall and 56" minimum measured perpendicular from the rear wall. A minimum 60" wide and 48' deep maneuvering space shall be provided in front of the water closet. [Exception: In residential dwelling units required to be mobility accessible, maneuvering space in front of the water closet shall be a minimum 60" wide and 36" deep.] The centerline of the water closet shall be 17" minimum to 18" maximum from the side wall or partition. The water closet seat height shall be 17" minimum to 19" maximum above finished floor. Water closets shall be arranged for a left-hand or right-hand approach, with the flush on the open side. The required clearance around the water closet shall be permitted to overlap the water closet, associated grab bars, dispensers, sanitary napkin disposal units, coat hooks, shelves, accessible routes, clear floor space and clearances required at other fixtures, and the turning space. No other fixtures or obstructions shall be located within the required water closet clearance. [Exception: In residential dwelling units, a lavatory shall be permitted on the rear wall 18" minimum from the water closet centerline where the clearance at the water closet is 66" minimum measured perpendicular from the rear wall.] The side wall grab bar shall be 42 inches long minimum, located 12 inches maximum from the rear wall and extending 54 inches minimum from the rear wall with the front end positioned 24 inches minimum in front of the water closet. The rear wall grab bar shall be 36" long minimum and extend from the centerline of the water closet 12" minimum on the closed side and 24" minimum on the open side. [EXCEPTIONS: 1. The rear grab bar shall be permitted to be 24" long minimum, centered on the water closet, where wall space does not permit a length of 36" minimum due to the location of a recessed fixture adjacent to the water closet. 2. Where an administrative authority requires flush controls for flush valves to be located in a position that conflicts with the location of the rear grab bar, then the rear grab bar shall be permitted to be split or shifted to the open side of the toilet area.] Grab bars should be installed in a horizontal position 33 inches to 36 inches maximum above the finish floor measured to the top of the gripping surface. Projecting fixtures/dispensers above grab bars shall be located minimum 12" above horizontal grab bars and minimum of 1- 1/2" below horizontal grab bars. Toilet paper dispensers shall be 7" minimum and 9" maximum in front of the water closet, measured to the centerline of the dispenser. The outlet of the dispenser shall be below the grab bar and 19" minimum above the finish floor. The toilet paper dispenser shall not be located behind grab bars. The top of projecting toilet paper dispensers shall be located 1-1/2" minimum below the grab bar. Dispensers shall not be of a type that controls delivery or that does not allow continuous paper flow. The lavatory shall maintain the maximum allowable height of 34" to the rim of the sink. The maximum allowable exterior bowl depth is 6-1/2". A compliant clear floor space of minimum 30" wide centered on the lavatory and minimum 48" deep, positioned for a forward approach, shall be provided. One full unobstructed side of the clear floor or ground space shall adjoin an accessible route or adjoin another clear floor or ground space. Where a clear floor or ground space is located in an alcove or otherwise confined on all or part of three sides, additional maneuvering clearance shall be provided. Alcoves shall be 36" wide minimum where the depth exceeds 24". Alcoves shall be 60" wide minimum where the depth exceeds 15". Space under an element between 9" and 29" above the finish floor or ground shall be considered knee clearance and shall comply. Knee clearance shall be 11" deep minimum at 9" above the finish floor or ground, and 8" deep minimum at 27" above the finish floor. The bottom of the front of the lavatory shall be minimum 29" above the finish floor. Knee clearance reduction is not allowed. Toe clearance shall be minimum 25" horizontal depth between the finish floor and 9" AFF. Knee and toe clearance shall be 30" wide minimum and centered on the lavatory. A compliant clear floor space, positioned for a forward approach, and compliant knee and toe clearance shall be provided. [EXCEPTIONS: 1. Toe clearance shall extend 19” maximum under lavatories 2. A lavatory in a toilet room or bathing facility for a single occupant accessed only through a private office and not for common use or public use shall not be required to provide knee and toe clearance. 3. In residential dwelling units, cabinetry shall be permitted under lavatories and kitchen sinks provided that all of the following conditions are met: (a) the cabinetry can be removed without removal or replacement of the fixture; (b) the finish floor extends under the cabinetry; and (c) the walls behind and surrounding the cabinetry are finished.
4. A knee clearance of 24" minimum above the finish floor or ground shall be permitted at lavatories and sinks used primarily by children 6 through 12 years where the rim or counter surface is 31" maximum above the finish floor or ground. 5. A parallel approach complying with 305 shall be permitted to lavatories and sinks used primarily by children 5 years and younger.6. The dip of the overflow shall not be considered in determining knee and toe clearances. 7. No more than one bowl of a multi-bowl sink shall be required to provide knee and toe clearance.] The centerline of the lavatory shall be a minimum of 18" from the side wall or side partition, where the accessible lavatory is located adjacent the side wall /side. Floor or ground surfaces of a clear floor or ground space shall comply with 302. Changes in level are not permitted. [EXCEPTION: Slopes not steeper than 1:48 shall be permitted.] Provide a turning space within the restroom. Provide a turning space within the restroom.
Turning space shall be either a circular space or a T- shaped space. The circular turning space shall be a space of 60" diameter minimum. The space shall be permitted to include knee and toe clearance. The T-shaped turning space shall be a T-shaped space within a 60" square minimum with arms and base 36" wide minimum. Each arm of the T shall be clear of obstructions 12" minimum in each direction and the base shall be clear of obstructions 24" minimum. The space shall be permitted to include knee and toe clearance only at the end of either the base or one arm. Floor or ground surfaces of a turning space shall be level. Changes in level are not permitted. [EXCEPTION: Slopes not steeper than 1:48 shall be permitted.] [Advisory 304.2: Floor or Ground Surface Exception: Turning space "changes in level" refers to surfaces with slopes and to surfaces with abrupt rise 692 Submittal: November 1, 2024
Exception: Turning space changes in level refers to surfaces with slopes and to surfaces with abrupt rise exceeding 1/4". Such changes in level are prohibited in required clear floor and ground spaces, turning spaces, and in similar spaces where people using wheelchairs and other mobility devices must park their mobility aides, such as in wheelchair spaces, or maneuver to use elements such as at doors, fixtures, and telephones.] At least one of each type of fixture, element, control or dispenser in each toilet room shall be accessible, within allowable reach ranges. Where accessory dispensers, including towel dispensers, sanitary napkins, waste receptacles, or other accessories are provided, all operable parts and/or openings for the user including coin slots shall be maximum 40" above finish floor. [EXCEPTION: Does not apply to baby changing tables.] The bottom of the reflective surface of mirrors, not including the frame, shall be 40" maximum above finish floor when above lavatories and counters, and 35" maximum when not above sinks and counters. [ADVISORY: the top edge of the reflective surface of mirrors should be 74" minimum from finished floor.] Provide clear floor space 36" wide minimum and 60" long minimum at the open face of the compartment, with the long side open for the full width.
In standard roll-in type shower compartments, operable parts of controls and faucets shall be installed on the back wall of the compartment adjacent to the seat wall 19" minimum and 27" maximum from the seat wall; and shall be located above the grab bar, but no higher than 48" above the shower floor, with their centerline 39" to 41" above the shower floor. In alternate roll-in type shower compartments, operable parts of controls and faucets shall be installed on the side wall of the compartment adjacent to the seat wall 19" minimum and 27" maximum from the seat wall; and shall be located above the grab bar, but no higher than 48" above the shower floor, with their centerline at 39" to 41" above the shower floor. All controls and faucets shall be a single lever design, and require less than 5 lbs of force to operate. Where 2 or more shower stalls within the same functional area are accessible, at least one shall be the "opposite hand" from the other (left handed controls versus right handed controls). A shower spray unit with a hose 59" long minimum that can be used both as a fixed-position shower head and as a hand-held shower shall be provided. The shower spray unit shall have an on/off control with a non-positive shut-off. If an adjustable-height shower head on a vertical bar is used, the bar shall be installed so as not to obstruct the use of grab bars. Grab bars shall be located 33" minimum to 36" maximum above the finished floor. Grab bars with circular cross sections shall have an outside diameter of 1¼" minimum and 2" maximum. Grab bars with non-circular cross sections shall have a cross-section dimension of 2" maximum and a perimeter dimension of 4" minimum and 4.8" maximum. The space between the wall and the grab bar shall be 1- 1/2" minimum. The space between the grab bar and projecting objects above shall be 12" minimum. The space between the grab bar and projecting objects below shall be 1-1/2" minimum. Shower spray units shall deliver water that is 120°F (49°C) maximum. [EXCEPTION: Where subject to excessive vandalism, two fixed shower heads shall be permitted instead of a hand-held spray unit in facilities that are not medical care facilities, longterm care facilities, transient lodging guest rooms, or residential dwelling units.] Each shower head shall be installed so it can be operated independently of the other and shall have swivel angle adjustments, both vertically and horizontally. One shower head shall be located at a height of 48" maximum above the shower finish floor.
The shower spray unit shall deliver water with same pressure as shower head. Provide a compliant folding seat.
The shower seat shall be rectangular or L-shaped. All seats shall have the inside edge 2-1/2" maximum from the seat wall. The side edge of all seats shall be 1-1/2" from the adjacent rear wall. The forward edge of the rectangular seat shall extend 15" minimum to 16" maximum from the seat wall. At the narrower part of the Lshaped seat, the inside edge shall be 2-1/2" maximum from the seat wall, and the outside/front edge 15" minimum and 16" maximum from the seat wall. At the wider part of the L-shaped seat closer to the rear wall, the rear edge of the "L" portion of the seat shall be 1-1/2" maximum from the rear wall and the outside/front edge shall be 22" minimum and 23" maximum from the seat wall. The top of the seat shall be 17" minimum and 19" maximum above the finish floor. Enclosures for shower compartments shall not obstruct controls, faucets, and shower spray units or obstruct transfer from wheelchairs onto shower seats. Floor or ground surfaces of showers shall be sloped 1:48 maximum in any direction. Where drains are provided, grate openings shall be ¼" maximum and flush with the floor surface. Where a soap dish is provided, it shall be located on the control wall at 40" maximum above the shower floor, and within the reach limits from the seat.
Priority 3
Quantity
3 EA
Unit Cost
22,000.00
Total Cost
$ 66,000
693 Submittal: November 1, 2024
Photos for Barrier ID: AX394473
694 Submittal: November 1, 2024
695 Submittal: November 1, 2024
Barrier ID: AX394480
City of Industry Fire Station 118 INTERIOR
Assembly Restroom
Type Restroom/Bathroom-Unisex
ADA Standard 213.2 Exception 4
Barrier Detail
Less than 50% of multiple single user toilet rooms clustered at a single location are accessible.
Location Description Single User Restrooms
Observed Sep 28, 2023 by [email protected] Site Conditions
The cluster of 4 restrooms includes 3 Men's and 1 Women's singe user restrooms requiring that 2 Men's and 1 Women's restroom be accessible. No restrooms are accessible.
Resolution
Provide minimum 50% accessible single user toilet rooms in each cluster of single user toilet rooms. This barrier must be removed in conjunction with barrier ID 394473. The cost of this barrier removal is covered under ID 394473 and therefore, the cost of this ID is shown as $0.
Priority 3
Quantity
3 EA
Unit Cost
0.00 Total Cost
$ 0
Photos for Barrier ID: AX394480
696 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
METRO STATION
METRO STATION PAGE FACILITIES
697 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Site Plan:
METRO STATION PAGE FACILITIES
698 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Facility Floor Plan:
METRO STATION PAGE FACILITIES
699 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
FACILITY: METRO STATION
Facility Description:
Facility was constructed in the year .
Facility Address:
This facility is used for the following programs:
2013
Metro Station
Metrolink and Foothill Transit Parking
PV Solar Power Generation
EV Charging
600 S Brea Canyon Rd
METRO STATION PAGE FACILITIES
700 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-24
Facility: Metro Station
Deficiency:
Code References:
Elevator was not in service at time of site visit but it could not be determined if this was an isolated or temporary interruption in service.
Recommended Remediation:
Failure to take prompt action to effect repairs could constitute a violation of Federal laws and these requirements. Floor/Area: Parking Structure Room/Spot: Level 1
Priority: 1 Estimated Direct Cost: $2,000
Site Elements Elevator
Service
Measurement:
Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:A
Category Elevator Precedence 5 Year 1 Cost with GC (30%): $2,600 Comment #: MS-25
Facility: Metro Station
Deficiency:
Code References:
11B-216 / 11B-502.8
There is no "Unauthorized Parking Sign" sign at the entrance to the off-street parking.
Recommended Remediation:
Install "Unauthorized Parking Sign" sign. Install sign at either; 1) a conspicuous place at each entrance to an off-street parking facility OR 2) immediately adjacent to on-site accessible parking and visible from each parking space.
Floor/Area: Site Entrance 2
Room/Spot: Vehicular Entrance
Priority: 1 Estimated Direct Cost: $500
Site Elements Parking
Tow Away Sign
Measurement: 1 count
Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
General
Severity:A
Category Parking Precedence 5 Year 1 Cost with GC (30%): $650
METRO STATION PAGE FACILITIES
701 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-26
Facility: Metro Station
Deficiency:
Code References:
11B-216 / 11B-502.8
There is no "Unauthorized Parking Sign" sign at the entrance to the off-street parking.
Recommended Remediation:
Install "Unauthorized Parking Sign" sign. Install sign at either; 1) a conspicuous place at each entrance to an off-street parking facility OR 2) immediately adjacent to on-site accessible parking and visible from each parking space.
Floor/Area: Site Entrance 3
Room/Spot: Vehicular Entrance
Priority: 1 Estimated Direct Cost: $500
Site Elements Parking
Tow Away Sign
Measurement: 1 count
Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
General
Severity:A
Category Parking Precedence 5 Year 1 Cost with GC (30%): $650 Comment #: MS-27
Facility: Metro Station
Deficiency:
Code References:
11B-406.3.1
The running slope of the ramp is steeper than 1:12 (8.33%).
Recommended Remediation:
Remove and replace the concrete walk to achieve running slope less than 5%, or install ramp with handrails per 11B-405. Floor/Area: Site Entrance 3 Room/Spot: Vehicular Entrance
Priority: 1 Estimated Direct Cost: $7,020
Site Elements Accessible Route
Slopes
Measurement: 9.4 each
405.2 Quantity: 468 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Running Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $9,126
METRO STATION PAGE FACILITIES
702 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-28
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.12
Detectable warning surface is incorrectly placed between pedestrain to pedestrain transition and not at transition between vehicluar and pedestrian way.
Recommended Remediation:
Remove misplaced detectable warning surface and place at transition between vehicluar and pedestrian way. Floor/Area: Site Entrance 3 Room/Spot: Vehicular Entrance
Priority: 1 Estimated Direct Cost: $360
Site Elements Accessible Route
Detectable Warning
Surface
Measurement:
N/A Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $468 Comment #: MS-29
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of the curb ramp exceeds 1:48 (2.0 %)
perpendicular to the direction of travel.
Recommended Remediation:
Replace curb ramp and provide cross slope 1:48 maximum. Left flare Floor/Area: Northbound Platform
Room/Spot: Accessible Routes
Priority: 1 Estimated Direct Cost: $1,800
Site Elements At Grade Transitions
Parallel Curb Ramp
Measurement: 3.7 % grade
405.2 Quantity: 120 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category At Grade Transitions Precedence 5 Year 1 Cost with GC (30%): $2,340
METRO STATION PAGE FACILITIES
703 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-06
Facility: Metro Station
Deficiency:
Code References:
Depth of detectable warning is not 36 in min
Recommended Remediation:
Replace detactable warning tile with a 36 in by 48 in tile. Located at flush transition at south side of parking structure entranceeast entrance.
Floor/Area: Parking Structure
Room/Spot: Perimeter
Priority: 1 Estimated Direct Cost: $360
Site Elements Accessible Route
Flush transition
Measurement: 13 inches
Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $468 Comment #: MS-07
Facility: Metro Station
Deficiency:
Code References:
There is no cane detectable barrier or detectable warning tile at the flush transition between vehicle area inside the parking structure and pedestrian walk outside.
Recommended Remediation:
Install a detectable warning surface compliant with CBC 11B -705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways. 7 opening - 6 openings are 14 feet wide and 1 opening 8 feet wide.
Floor/Area: Parking Structure
Room/Spot: Perimeter
Priority: 1 Estimated Direct Cost: $8,280
Site Elements Accessible Route
Flush transition
Measurement:
Quantity: 92 LF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $10,764
METRO STATION PAGE FACILITIES
704 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-08
Facility: Metro Station
Deficiency:
Code References:
11B-810.3
Bus shelters do not provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter.
Recommended Remediation:
Relocate bench to provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter.
Alcove condition applies.
Floor/Area: Parking Structure
Room/Spot: Seating
Priority: 1 Estimated Direct Cost: $7,800
Site Elements Bus stop shelter
Wheelchair Space
Measurement:
810.3 Quantity: 6 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:A
Category Bus stop shelter Precedence 5 Year 1 Cost with GC (30%): $10,140 Comment #: MS-09
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of the POT exceeds 1:48 (2.0 %) perpendicular to the direction of travel.
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Parking Structure
Room/Spot: Perimeter
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 2.4 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900
METRO STATION PAGE FACILITIES
705 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-10
Facility: Metro Station
Deficiency:
Code References:
11B-810.3
Bus shelters do not provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter.
Recommended Remediation:
Relocate bench to provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter.
Located at south side of parking structure. Alcove condition applies.
Floor/Area: Parking Structure
Room/Spot: Seating
Priority: 1 Estimated Direct Cost: $5,200
Site Elements Bus stop shelter
Wheelchair Space
Measurement:
810.3 Quantity: 4 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:A
Category Bus stop shelter Precedence 5 Year 1 Cost with GC (30%): $6,760 Comment #: MS-11
Facility: Metro Station
Deficiency:
Code References:
11B-247.1.2.5
There is no cane detectable barrier or detectable warning tile at the flush transition between vehicle area inside the parking structure and pedestrian walk outside.
Recommended Remediation:
Install a detectable warning surface compliant with CBC 11B -705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways. 7 opening - 2 openings are 12.5 feet wide and 5 opening are 10.5 feet wide.
Floor/Area: Parking Structure
Room/Spot: Seating
Priority: 1 Estimated Direct Cost: $7,020
Site Elements Accessible Route
Flush transition
Measurement:
Quantity: 78 LF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $9,126
METRO STATION PAGE FACILITIES
706 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-12
Facility: Metro Station
Deficiency:
Code References:
11B-216 / 11B-502.8.2
The verbiage on the "tow-away" sign is not compliant with 2019 CBC.
Recommended Remediation:
Sign shall clearly state the following: "Unauthorized vehicles parked in designated accessible spaces not displaying distinguishing placards or special license plates issued for persons with disabilities will be towed away at the owner's expense. Towed vehicles may be reclaimed at:
_________________________ or by telephoning
_______________________." Missing "special" and change "may" to "will be" Floor/Area: Parking Structure
Room/Spot: Perimeter
Priority: 5 Estimated Direct Cost: $500
Site Elements Parking
Tow Away Sign
Measurement: 1 count
N/A Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Verbiage
Severity:D
Category Parking Precedence 5 Year 1 Cost with GC (30%): $650 Comment #: MS-13
Facility: Metro Station
Deficiency:
Code References:
11B-247.1.2.5
There is no detectable warning tile at the flush transition between vehicle area across bottom landing of stairs .
Recommended Remediation:
Install a detectable warning surface compliant with CBC 11B -705, across the entire width of the flush transition between pedestrian and vehicular right-of-ways.
Floor/Area: Parking Structure
Room/Spot: Perimeter
Priority: 1 Estimated Direct Cost: $3,960
Site Elements Accessible Route
Flush transition
Measurement: 44 feet
Quantity: 44 LF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $5,148
METRO STATION PAGE FACILITIES
707 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-14
Facility: Metro Station
Deficiency:
Code References:
11B-504.4.1
Warning stripes are not provided at all treads and/or the upper approach.
Recommended Remediation:
Add contrasting stripes between 2 and 4 inches wide across the entire width of each tread and/or the upper approach. Floor/Area: Parking Structure Room/Spot: Perimeter
Priority: 5 Estimated Direct Cost: $156
Site Elements Stairs
Contrast Striping
Measurement: 2 ln ft
N/A Quantity: 26 LF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Exterior Stair
Severity:D
Category Stairs Precedence 5 Year 1 Cost with GC (30%): $203 Comment #: MS-15
Facility: Metro Station
Deficiency:
Code References:
11B-505.10.1
Handrails at the top and/or bottom of the stairs do not extend 12- inches horizontally above the landing.
Recommended Remediation:
Install bottom handrail extensions at stairs: Stair handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the bottom of the stair runs.
ADA Does not require handrail extensions at the bottom of staircases.
Floor/Area: Parking Structure
Room/Spot: Perimeter
Priority: 5 Estimated Direct Cost: $1,380
Site Elements Stairs
Handrails
Measurement: 23 inches
N/A Quantity: 12 inches
1991 ADAAG:
2010 ADAS:
2016 CBC:
Extensions: Bottom
Severity:D
Category Stairs Precedence 5 Year 1 Cost with GC (30%): $1,794
METRO STATION PAGE FACILITIES
708 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-16
Facility: Metro Station
Deficiency:
Code References:
11B-505.8
Surfaces adjacent to handrail are sharp and/or abrasive, and/or do not provide rounded edges.
Recommended Remediation:
Remove sharp items, provide a smooth surface, and/or created 1/8" minimum radius for surfaces adjacent to handrails.
Handrail gripping surfaces and any surfaces adjacent to them shall be free of sharp or abrasive elements and shall have rounded edges.
Floor/Area: Parking Structure
Room/Spot: Perimeter
Priority: 1 Estimated Direct Cost: $805
Site Elements Stairs
Handrails
Measurement: 1 count
505.8 Quantity: 7 FT
1991 ADAAG:
2010 ADAS:
2016 CBC:
Surfaces
Severity:C
Category Stairs Precedence 5 Year 1 Cost with GC (30%): $1,047 Comment #: MS-17
Facility: Metro Station
Deficiency:
Code References:
11B-505.4
Handrail heights are not consistent heights for entire stair run.
Recommended Remediation:
Adjust handrail heights to provide handrails that are a consistent height above walking surfaces, and stair surfaces. Floor/Area: Parking Structure Room/Spot: Perimeter
Priority: 1 Estimated Direct Cost: $575
Site Elements Stairs
Handrails
Measurement: 1 count
505.4 Quantity: 5 FT
1991 ADAAG:
2010 ADAS:
2016 CBC:
Height
Severity:C
Category Stairs Precedence 5 Year 1 Cost with GC (30%): $748
METRO STATION PAGE FACILITIES
709 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-18
Facility: Metro Station
Deficiency:
Code References:
11B-505.2
Handrails are not provided on both sides of the staircase.
Recommended Remediation:
Install missing handrails so they are provided on both sides of stairs and ramps. Floor/Area: Parking Structure
Room/Spot: Perimeter
Priority: 1 Estimated Direct Cost: $575
Site Elements Stairs
Handrails
Measurement: 1 count
505.2 Quantity: 5 FT
1991 ADAAG:
2010 ADAS:
2016 CBC:
Both Sides
Severity:C
Category Stairs Precedence 5 Year 1 Cost with GC (30%): $748 Comment #: MS-19
Facility: Metro Station
Deficiency:
Code References:
11B-303.5
Warning curb / guide rail is not installed at locations where there is an elevation change of more than 4” above finish grade.
Recommended Remediation:
Add a guardrail and edge protection that does not allow the passing of a 4 inch diameter sphere. Floor/Area: Parking Structure Room/Spot: Stairs at Northwest Corner
Priority: 5 Estimated Direct Cost: $225
Site Elements Accessible Route
Change in Level
Measurement: 9 ln ft
N/A Quantity: 9 LF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Warning Curbs
Severity:D
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $293
METRO STATION PAGE FACILITIES
710 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-20
Facility: Metro Station
Deficiency:
Code References:
11B-505.10.1
Handrails at the top and/or bottom of the stairs do not extend 12- inches horizontally above the landing.
Recommended Remediation:
Install bottom handrail extensions at stairs: Stair handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the bottom of the stair runs.
ADA Does not require handrail extensions at the bottom of staircases.
Floor/Area: Parking Structure
Room/Spot: Stairs at Northwest Corner
Priority: 5 Estimated Direct Cost: $115
Site Elements Stairs
Handrails
Measurement: 1 each
N/A Quantity: 1 FT
1991 ADAAG:
2010 ADAS:
2016 CBC:
Extensions: Bottom
Severity:D
Category Stairs Precedence 5 Year 1 Cost with GC (30%): $150 Comment #: MS-21
Facility: Metro Station
Deficiency:
Code References:
There is no detectable warning surface (truncated dome mat) at the flush transition between the pedestrian and vehicular right-ofways.
Recommended Remediation:
Provide a 36 in min deep detectable warning across entire flush transition at all levels of parking structure. Floor/Area: Parking Structure Room/Spot: All Levels
Priority: Estimated Direct Cost: $9,000
Site Elements Accessible Route
Flush transition
Measurement: 80 feet
Quantity: 25 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Detectable Warning
Surface
Severity:
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $11,700
METRO STATION PAGE FACILITIES
711 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-22
Facility: Metro Station
Deficiency:
Code References:
11B-404.2.9
Objects in the path of travel extend more than 4 inches from the wall with no cane detectable barrier.
Recommended Remediation:
Protruding objects are identified as extending more than 4- inches from wall 27-inches minimum to 80-inches maximum AFF. Provide a cane detectable barrier under object or relocate items outside of circulation path. At all levels
Floor/Area: Parking Structure
Room/Spot: All Levels
Priority: 1 Estimated Direct Cost: $450
Site Elements Accessible Route
Protrusion
Measurement: 8 each
404.2.9 Quantity: 5 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Depth
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $585 Comment #: MS-23
Facility: Metro Station
Deficiency:
Code References:
11B-407.2.3
Raised star at floor designation sign at hoistway entrance is not equally proportioned.
Recommended Remediation:
Replace hoistway plates so that the outside diameter of the star is 2 inches and all points are of equal length. Elevator was not in service at the time of site visit.
Floor/Area: Parking Structure
Room/Spot: Level 1
Priority: 1 Estimated Direct Cost: $300
Site Elements Elevator
Hoistway Signs
Measurement:
Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:A
Category Elevator Precedence 5 Year 1 Cost with GC (30%): $390
METRO STATION PAGE FACILITIES
712 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-30
Facility: Metro Station
Deficiency:
Code References:
11B-810.3
Bus shelters do not provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter.
Recommended Remediation:
Relocate bench to provide a minimum clear floor or ground space complying with Section 11B-305 entirely within the shelter. Floor/Area: Northbound Platform Room/Spot: Seating
Priority: 1 Estimated Direct Cost: $5,200
Site Elements Bus stop shelter
Wheelchair Space
Measurement:
810.3 Quantity: 4 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:C
Category Bus stop shelter Precedence 5 Year 1 Cost with GC (30%): $6,760 Comment #: MS-01
Facility: Metro Station
Deficiency:
Code References:
11B-216 / 11B-502.8
There is no "Unauthorized Parking Sign" sign at the entrance to the off-street parking.
Recommended Remediation:
Install "Unauthorized Parking Sign" sign. Install sign at either; 1) a conspicuous place at each entrance to an off-street parking facility OR 2) immediately adjacent to on-site accessible parking and visible from each parking space. Exising Sign is located at entrance to parking structure beyond this vehicular entrance.
There is parking beyond the parking structure that require Tow away sign.
Floor/Area: Site Entrance 1
Room/Spot: Vehicular Entrance
Priority: 5 Estimated Direct Cost: $500
Site Elements Parking
Tow Away Sign
Measurement: 0 count
N/A Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
General
Severity:D
Category Parking Precedence 5 Year 1 Cost with GC (30%): $650
METRO STATION PAGE FACILITIES
713 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-02
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.2
Width: There is no 48 inches minimum landing provided at the top of the perpendicular curb ramp.
Recommended Remediation:
Replace curb ramp and landing. Obstructed by storm drain manhole adjacent to top landing.
The clear width of curb ramp runs (excluding any flared sides), blended transitions, and turning spaces shall be 48 inches (1219 mm) minimum. The landing clear width shall be at least as wide as the curb ramp, excluding any flared sides, or the blended transition leading to the landing.
Floor/Area: Site Entrance 1
Room/Spot: Vehicular Entrance
Priority: 1 Estimated Direct Cost: $975
Site Elements At Grade Transitions
Perpendicular Curb
Ramp
Measurement: 41 each
406.4 Quantity: 65 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Landing Width
Severity:C
Category At Grade Transitions Precedence 5 Year 1 Cost with GC (30%): $1,268 Comment #: MS-03
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.3
The slope of the landing at the top of the curb ramp is greater than 1:48 (2.0%) in any direction.
Recommended Remediation:
Replace curb ramp and landing. Obstructed by storm drain manhole adjacent to top landing. Floor/Area: Site Entrance 1 Room/Spot: Vehicular Entrance
Priority: 1 Estimated Direct Cost: $7,500
Site Elements At Grade Transitions
Perpendicular Curb
Ramp
Measurement: 3.2 % grade
Quantity: 500 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Landing Slope
Severity:A
Category At Grade Transitions Precedence 5 Year 1 Cost with GC (30%): $9,750
METRO STATION PAGE FACILITIES
714 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-04
Facility: Metro Station
Deficiency:
Code References:
Route is not closed off to persons with visual impairements.
Dead end at west side of gate, leading to wall.
Recommended Remediation:
Provide cane detectable pedestrian barrier.
Floor/Area: Site Entrance 1
Room/Spot: Vehicular Entrance
Priority: 1 Estimated Direct Cost: $540
Site Elements Accessible Route
Continuity - accessible
route leads to dead end
Measurement:
Quantity: 6 FT
1991 ADAAG:
2010 ADAS:
2016 CBC:
Route
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $702 Comment #: MS-05
Facility: Metro Station
Deficiency:
Code References:
Depth of detectable warning is not 36 in min
Recommended Remediation:
Replace detactable warning tile with a 36 in by 48 in tile. Located at flush transition at north side of parking structure entranceeast entrance.
Floor/Area: Parking Structure
Room/Spot: Perimeter
Priority: 1 Estimated Direct Cost: $360
Site Elements Accessible Route
Flush transition
Measurement: 17 inches
Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $468
METRO STATION PAGE FACILITIES
715 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-63
Facility: Metro Station
Deficiency:
Code References:
11B-406.3.1
The running slope of the ramp is steeper than 1:12 (8.33%).
Grade varies from 7.9 to 8.9% throughout ramp runs.
Recommended Remediation:
Perform survey of each ramp run's top and bottom landing elevations to determine if 8.33% is achieveable at each of the ramp runs. Repair concrete surface to 8.33% if achievable or remove and replace incorrectable legs of ramp.
Floor/Area: Ramp at south west corner
Room/Spot: of site
Ramp at south west corner of site
Priority: 1 Estimated Direct Cost: $34,920
Site Elements Ramps
Slopes
Measurement: 8.9 % grade
405.2 Quantity: 388 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
Running Slope
Severity:A
Category Ramps Precedence 5 Year 1 Cost with GC (30%): $45,396 Comment #: MS-64
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of the ramp exceeds 1:48 (2.0 %) perpendicular to the direction of travel.
Recommended Remediation:
The cross slope of curb ramps and blended transitions shall be 1:48 maximum. Top most leg of giant ramp Floor/Area: Ramp at south west corner Room/Spot: of site
Ramp at south west corner of site
Priority: 1 Estimated Direct Cost: $1,440
Site Elements Ramps
Slopes
Measurement: 2.7 % grade
405.2 Quantity: 96 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Ramps Precedence 5 Year 1 Cost with GC (30%): $1,872
METRO STATION PAGE FACILITIES
716 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-65
Facility: Metro Station
Deficiency:
Code References:
11B-505.10.1
Handrails at the top and/or bottom of the ramp do not extend 12- inches horizontally above the landing.
Recommended Remediation:
Install top and bottom handrail extensions at ramps: Ramp handrails shall extend horizontally above the landing for 12 inches (305 mm) minimum beyond the top and bottom of the ramp runs.
Floor/Area: Ramp at south west corner
Room/Spot: of site
Ramp at south west corner of site
Priority: 1 Estimated Direct Cost: $250
Site Elements Ramps
Handrails
Measurement: 9 inches
505.10.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Extensions
Severity:C
Category Ramps Precedence 5 Year 1 Cost with GC (30%): $325 Comment #: MS-66
Facility: Metro Station
Deficiency:
Code References:
11B-505.4
Handrail heights are not consistent heights for entire ramp run.
Recommended Remediation:
Adjust handrail heights to provide handrails that are a consistent height above walking surfaces, and ramp surfaces. Floor/Area: Ramp at south west corner Room/Spot: of site
Ramp at south west corner of site
Priority: 1 Estimated Direct Cost: $3,500
Site Elements Ramps
Handrails
Measurement: 0
505.4 Quantity: 700 ln ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
Height
Severity:C
Category Ramps Precedence 5 Year 1 Cost with GC (30%): $4,550
METRO STATION PAGE FACILITIES
717 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-31
Facility: Metro Station
Deficiency:
Code References:
11B-208.2.4
One access space in every six access spaces (or portion of 6) is not van accessible.
Recommended Remediation:
Reconfigure spaces by repainting lines. Include signage indicating van accessible spaces. Van accessible stalls are not properly assigned. Some are indicated as van accessible but are not, and vice versa.
Floor/Area: Set of 14 accessible stalls
Room/Spot: To the left of platform
Set of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $1,600
Site Elements Parking
General Parking
Measurement: 3 count
208.2.4 Quantity: 4 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Van Stall Space Count
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $2,080 Comment #: MS-32
Facility: Metro Station
Deficiency:
Code References:
11B-502.3
Markings are faded and does not discourage parking in the access aisle.
Recommended Remediation:
Remove old markings and repaint as required.
Floor/Area: Set of 14 accessible stalls
Room/Spot: To the left of platform
Set of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $5,250
Site Elements Parking
Access Aisle Markings
Measurement: 7 count
502 Quantity: 7 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
"No Parking"
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $6,825
METRO STATION PAGE FACILITIES
718 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-33
Facility: Metro Station
Deficiency:
Code References:
11B-502.2
The accessible van/car stall is less than 216 inches (18 ft. or 5486 mm) long.
Recommended Remediation:
Car and van parking spaces shall be 216 inches (5486 mm) long minimum.
ADA does not designate a minimum length for van or car
accessible stalls. 217.5” to end of striping which is on a gutter at a noncompliant 2.9% slope
Floor/Area: Set of 14 accessible stalls
Room/Spot: To the left of platform
Set of 14 accessible stalls
Priority: 5 Estimated Direct Cost: $3,500
Site Elements Parking
Accessible Stall
Measurement: 201 inches
502.2 Quantity: 7 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Length
Severity:D
Category Parking Precedence 5 Year 1 Cost with GC (30%): $4,550 Comment #: MS-34
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 2.3 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900
METRO STATION PAGE FACILITIES
719 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-35
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 2.4 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900 Comment #: MS-36
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 3.8 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900
METRO STATION PAGE FACILITIES
720 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-37
Facility: Metro Station
Deficiency:
Code References:
11B-404.2.9
Objects in the path of travel extend more than 4 inches from the wall with no cane detectable barrier.
Recommended Remediation:
Trim the tree branches so that a vertical clearance of minimum 80 inches is maintained along all pedestrian pathways. Floor/Area: Route to Platform Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $90
Site Elements Accessible Route
Protrusion
Measurement: 24 inches
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Height
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $117 Comment #: MS-38
Facility: Metro Station
Deficiency:
Code References:
11B-707.3, 11B-309
Operable parts are not differentiated by sound or touch, without activation.
Recommended Remediation:
Unless a "Clear" or "Correct" key is provided, each operable part should be able to be differentiated by sound or touch, without activation. Floor/Area: Fare machines
Room/Spot:
Fare machines
Priority: 4 Estimated Direct Cost: $500
Goods and Services Fare Machine
Measurement: 1 count
707.3 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Operable Parts
Severity:C
Category Fare Machine Precedence 8 Year 3 Cost with GC (30%): $650
METRO STATION PAGE FACILITIES
721 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-39
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 2.9 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900 Comment #: MS-40
Facility: Metro Station
Deficiency:
Code References:
11B-404.2.9
Objects in the path of travel extend more than 4 inches from the wall with no cane detectable barrier.
Recommended Remediation:
Trim the tree branches so that a vertical clearance of minimum 80 inches is maintained along all pedestrian pathways. Floor/Area: Route to Platform Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $90
Site Elements Accessible Route
Protrusion
Measurement: 26 inches
404.2.9 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Height
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $117
METRO STATION PAGE FACILITIES
722 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-41
Facility: Metro Station
Deficiency:
Code References:
11B-707.5.2
Speech output does not provide audible information found on receipts.
Recommended Remediation:
Speech output shall provide audible information found on receipts. Floor/Area: Fare machines
Room/Spot:
Fare machines
Priority: 4 Estimated Direct Cost: $500
Goods and Services Fare Machine
50% of Machines
Measurement: 0 count
707.5.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Speech
Severity:C
Category Fare Machine Precedence 8 Year 3 Cost with GC (30%): $650 Comment #: MS-42
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 2.3 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900
METRO STATION PAGE FACILITIES
723 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-43
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 5.2 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900 Comment #: MS-44
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 2.6 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900
METRO STATION PAGE FACILITIES
724 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-45
Facility: Metro Station
Deficiency:
Code References:
11B-302.3
Accessible route grates / openings exceed ½” in the direction of travel.
Recommended Remediation:
Replace grates, or fill openings, at locations where
gratings/openings occur. Openings are allowed a maximum of ½” in the direction of travel.
If gratings have elongated openings, then they are placed so that the long dimension is perpendicular to the dominant direction of travel.
Floor/Area: Route to Platform
Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $150
Site Elements Accessible Route
Openings
Measurement: .75 inches
302.3 Quantity: 10 LF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Width
Severity:B
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $195 Comment #: MS-46
Facility: Metro Station
Deficiency:
Code References:
11B-402.2
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 2.1 % grade
402.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:C
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900
METRO STATION PAGE FACILITIES
725 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-47
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 2.6 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900 Comment #: MS-48
Facility: Metro Station
Deficiency:
Code References:
11B-204.2
One standing and one wheelchair accessible drinking fountain is not provided at each location.
Recommended Remediation:
No fewer than two drinking fountains shall be provided. When provided, one drinking fountain shall comply with meet
requirements for a standing person and one drinking fountain shall be wheelchair accessible. A combo unit can be provided if all items are compliant.
Floor/Area: Drinking Fountain
Room/Spot:
Drinking Fountain
Priority: 3 Estimated Direct Cost: $5,000
Goods and Services Drinking Fountain
Number Provided
Measurement: 0 count
204.2 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Hi/Lo
Severity:C
Category Drinking Fountain Precedence 8 Year 3 Cost with GC (30%): $6,500
METRO STATION PAGE FACILITIES
726 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-49
Facility: Metro Station
Deficiency:
Code References:
11B-303.2, 11B-303.3
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Route to Platform
Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $90
Site Elements Accessible Route
Vertical Displacment
Measurement: .25 inches
303.2, 303.3 Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Height
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $117 Comment #: MS-50
Facility: Metro Station
Deficiency:
Code References:
11B-302.1, 11B-403.2
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Route to Platform
Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $90
Site Elements Accessible Route
Vertical Displacment
Measurement: 1 count
302.1, 403.2 Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Height
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $117
METRO STATION PAGE FACILITIES
727 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-51
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 2.5 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900 Comment #: MS-52
Facility: Metro Station
Deficiency:
Code References:
11B-302.3
Accessible route grates / openings exceed ½” in the direction of travel.
Recommended Remediation:
Replace grates, or fill openings, at locations where
gratings/openings occur. Openings are allowed a maximum of ½” in the direction of travel.
If gratings have elongated openings, then they are placed so that the long dimension is perpendicular to the dominant direction of travel.
Floor/Area: Route to Platform
Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $60
Site Elements Accessible Route
Openings
Measurement: 1 inches
302.3 Quantity: 4 LF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Width
Severity:B
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $78
METRO STATION PAGE FACILITIES
728 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-53
Facility: Metro Station
Deficiency:
Code References:
11B-406.5.7
The cross slope of accessible routes exceeds 1:48 (2.0 %).
Recommended Remediation:
Remove and dispose of noncompliant materials. Regrade and replace cement. Floor/Area: Route to Platform
Room/Spot:
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Accessible Route
Slopes
Measurement: 2.5 % grade
405.2 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Cross Slope
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $3,900 Comment #: MS-54
Facility: Metro Station
Deficiency:
Code References:
11B-302.3
Accessible route grates / openings exceed ½” in the direction of travel.
Recommended Remediation:
Replace grates, or fill openings, at locations where
gratings/openings occur. Openings are allowed a maximum of ½” in the direction of travel.
If gratings have elongated openings, then they are placed so that the long dimension is perpendicular to the dominant direction of travel.
Floor/Area: Route to Platform
Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $45
Site Elements Accessible Route
Openings
Measurement: 1 inches
302.3 Quantity: 3 LF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Width
Severity:B
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $59
METRO STATION PAGE FACILITIES
729 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-55
Facility: Metro Station
Deficiency:
Code References:
11B-303.2, 11B-303.3
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Route to Platform
Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $90
Site Elements Accessible Route
Vertical Displacment
Measurement: .25 inches
303.2, 303.3 Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Height
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $117 Comment #: MS-56
Facility: Metro Station
Deficiency:
Code References:
11B-303.2, 11B-303.3
There exists a height difference between concrete slabs of equal to or greater than 1/4 inch.
Recommended Remediation:
Grind or Bevel concrete to provide a difference in height of no greater than 1/4 inch while maintaining 1:48 slope maximum in any direction.
Floor/Area: Route to Platform
Room/Spot:
Bank of 14 accessible stalls
Priority: 1 Estimated Direct Cost: $180
Site Elements Accessible Route
Vertical Displacment
Measurement: 1.25 inches
303.2, 303.3 Quantity: 2 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Height
Severity:A
Category Accessible Route Precedence 5 Year 1 Cost with GC (30%): $234
METRO STATION PAGE FACILITIES
730 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-57
Facility: Metro Station
Deficiency:
Code References:
11B-502.1
The accessible car stall is less than 108 inches (9 ft) wide but is federally compliant.
Recommended Remediation:
Car parking spaces shall be 108 inches) wide minimum.
ADA requires 96-inches (8 ft) minimum width.
Floor/Area: Set of 9 accessible stalls
Room/Spot: In front of platform
Set of 9 accessible stalls in front of
platform
Priority: 5 Estimated Direct Cost: $400
Site Elements Parking
Accessible Stall
Measurement: 97.5 inches
502.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Width
Severity:D
Category Parking Precedence 5 Year 1 Cost with GC (30%): $520 Comment #: MS-58
Facility: Metro Station
Deficiency:
Code References:
11B-502.3
Markings are faded and does not discourage parking in the access aisle.
Recommended Remediation:
Remove old markings and repaint as required. 5 out of 6 are faded Floor/Area: Set of 9 accessible stalls
Room/Spot: In front of platform
Set of 9 accessible stalls in front of
platform
Priority: 1 Estimated Direct Cost: $3,750
Site Elements Parking
Access Aisle Markings
Measurement: 5 count
502 Quantity: 5 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
"No Parking"
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $4,875
METRO STATION PAGE FACILITIES
731 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-59
Facility: Metro Station
Deficiency:
Code References:
11B-502.4
The slope of the access aisle in any direction exceeds 1:48 (2.0%) grade. 5 out of 6 access aisles have built up ramps with excessive running slope.
Recommended Remediation:
Re-grade and resurface the access aisle to provide 1:48 maximum slopes in all directions.
Floor or ground surfaces. Parking spaces and access aisles serving them shall comply with Section 11B-302. Access aisles shall be at the same level as the parking spaces they serve.
Changes in level are not permitted.
Floor/Area: Set of 9 accessible stalls
Room/Spot: In front of platform
Set of 9 accessible stalls in front of
platform
Priority: 1 Estimated Direct Cost: $6,750
Site Elements Parking
Access Aisle
Measurement: 6 % grade
502.4 Quantity: 450 sq ft
1991 ADAAG:
2010 ADAS:
2016 CBC:
Slope
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $8,775 Comment #: MS-60
Facility: Metro Station
Deficiency:
Code References:
11B-502.6.2
The parking identification sign does not includes the text "Minimum Fine $250" below the ISA.
Recommended Remediation:
Additional language or an additional sign below the International Symbol of Accessibility shall state “Minimum Fine $250”. Floor/Area: Set of 9 accessible stalls Room/Spot: In front of platform
Set of 9 accessible stalls in front of
platform
Priority: 5 Estimated Direct Cost: $4,500
Site Elements Parking
Signage
Measurement: 9 count
N/A Quantity: 9 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Minimum Fine
Severity:D
Category Parking Precedence 5 Year 1 Cost with GC (30%): $5,850
METRO STATION PAGE FACILITIES
732 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-61
Facility: Metro Station
Deficiency:
Code References:
1” vertical displacement in accessible stall
Recommended Remediation:
Provide leveling surface
Floor/Area: Set of 9 accessible stalls
Room/Spot: In front of platform
Set of 9 accessible stalls in front of
platform
Priority: 1 Estimated Direct Cost: $90
Site Elements Parking
Accessible Route
Measurement: 1 inches
Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Vertical displacement
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $117 Comment #: MS-62
Facility: Metro Station
Deficiency:
Code References:
11B-704
The Public Telephone is not wheelchair accessible. The highest operable part is above the maximum reach range. There is no TTY provided.
Recommended Remediation:
Relocate the telephone to provide a 30 inch by 48 inch clear floor space, oriented forward for parallel approach, unobstructed by bases and enclosures. Lower the telephone so that the highest operable part doe not exceed the allowable 48 inches AFF.
Provide a permanently affixed TTY. Public telephone 1 provided Floor/Area:
Room/Spot:
Priority: 2 Estimated Direct Cost: $700
Goods and Services Public Telephone
Reach Range
Measurement: 55 inches
704 Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Height
Severity:C
Category Public Telephone Precedence 8 Year 3 Cost with GC (30%): $910
METRO STATION PAGE FACILITIES
733 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-67
Facility: Metro Station
Deficiency:
Code References:
11B-502.2
The accessible van/car stall is less than 216 inches (18 ft. or 5486 mm) long.
Recommended Remediation:
Car and van parking spaces shall be 216 inches (5486 mm) long minimum.
ADA does not designate a minimum length for van or car
accessible stalls.
Floor/Area: Set of 3 accessible stalls
Room/Spot:
Set of 3 accessible stalls
Priority: 5 Estimated Direct Cost: $1,500
Site Elements Parking
Accessible Stall
Measurement: 202 inches
502.2 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Length
Severity:D
Category Parking Precedence 5 Year 1 Cost with GC (30%): $1,950 Comment #: MS-68
Facility: Metro Station
Deficiency:
Code References:
11B-502.1
The accessible car stall is less than 108 inches (9 ft) wide but is federally compliant.
Recommended Remediation:
Car parking spaces shall be 108 inches wide minimum.
ADA requires 96-inches (8 ft) minimum width.
Floor/Area: Set of 3 accessible stalls
Room/Spot:
Set of 3 accessible stalls
Priority: 5 Estimated Direct Cost: $400
Site Elements Parking
Accessible Stall
Measurement: 106 inches
502.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Width
Severity:D
Category Parking Precedence 5 Year 1 Cost with GC (30%): $520
METRO STATION PAGE FACILITIES
734 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-69
Facility: Metro Station
Deficiency:
Code References:
11B-502.2, 11B-502.3.1
The van stall is not a minimum 144 inches wide, OR 108 inches when the adjacent access aisle is minimum 96 inches wide.
Recommended Remediation:
Van parking spaces shall be 144 inches (3658 mm) wide minimum.
Exception: Van parking spaces shall be permitted to be 108 inches (2743 mm) wide minimum where the access aisle is 96 inches (2438 mm) wide minimum.
ADA requires 132-inch (11 ft. / 3350 mm) wide minimum where the access aisle is 60-inches wide minimum. OR 96-inches (8 ft./2438 mm) minimum width when a 96-inch where the access aisle is 96 inches wide minimum.
Floor/Area: Set of 3 accessible stalls
Room/Spot:
Set of 3 accessible stalls
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Accessible Stall
Measurement: 106 inches
502.2 Quantity: 2 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Van Stall Width
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $1,950 Comment #: MS-70
Facility: Metro Station
Deficiency:
Code References:
11B-502.3.4
The access aisle for an accessible van stall is not located on the passenger side of the parking space.
Recommended Remediation:
Repaint to provide access aisles located on the passenger side of the van accessible spaces. Floor/Area: Set of 3 accessible stalls Room/Spot:
Set of 3 accessible stalls
Priority: 1 Estimated Direct Cost: $750
Site Elements Parking
Access Aisle
Measurement: 1 count
Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Van Stall Location
Severity:A
Category Parking Precedence 5 Year 1 Cost with GC (30%): $975
METRO STATION PAGE FACILITIES
735 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-71
Facility: Metro Station
Deficiency:
Code References:
11B-502.3
Markings are faded and does not discourage parking in the access aisle.
Recommended Remediation:
Remove old markings and repaint as required.
Floor/Area: Set of 3 accessible stalls
Room/Spot:
Set of 3 accessible stalls
Priority: 1 Estimated Direct Cost: $2,250
Site Elements Parking
Access Aisle Markings
Measurement: 1
Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
"No Parking"
Severity:A
Category Parking Precedence 5 Year 1 Cost with GC (30%): $2,925 Comment #: MS-72
Facility: Metro Station
Deficiency:
Code References:
11B-502.6.4.1
The centerline of the ISA marking is greater than 6 inches (152 mm) from the centerline of the parking stall.
Recommended Remediation:
Repaint the ISA marking. The centerline of the International Symbol of Accessibility shall be a maximum of 6 inches (152 mm) from the centerline of the parking space, its sides parallel to the length of the parking space and its lower corner at, or lower side aligned with, the end of the parking space.
Floor/Area: Set of 3 accessible stalls
Room/Spot:
Set of 3 accessible stalls
Priority: 1 Estimated Direct Cost: $350
Site Elements Parking
ISA
Measurement: 6.5 inches
Quantity: 1 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Centerline
Severity:A
Category Parking Precedence 5 Year 1 Cost with GC (30%): $455
METRO STATION PAGE FACILITIES
736 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-73
Facility: Metro Station
Deficiency:
Code References:
11B-502.6.2
The parking identification sign does not includes the text "Minimum Fine $250" below the ISA.
Recommended Remediation:
Additional language or an additional sign below the International Symbol of Accessibility shall state “Minimum Fine $250”. Floor/Area: Set of 3 accessible stalls Room/Spot:
Set of 3 accessible stalls
Priority: 1 Estimated Direct Cost: $1,500
Site Elements Parking
Signage
Measurement: 3 count
Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Minimum Fine
Severity:A
Category Parking Precedence 5 Year 1 Cost with GC (30%): $1,950 Comment #: MS-74
Facility: Metro Station
Deficiency:
Code References:
11B-502.6.4.1
The lower corner or lower side of the ISA identifying the accessible parking stall is not aligned with the end of the parking stall length.
Recommended Remediation:
Repaint the ISA marking. The International Symbol of
Accessibility shall its lower corner at, or lower side aligned with, the end of the parking space.
Floor/Area: Set of 2 accessible stalls
Room/Spot:
Set of 2 accessible stalls
Priority: 1 Estimated Direct Cost: $700
Site Elements Parking
ISA
Measurement: 2 count
Quantity: 2 Each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Bottom Corner
Severity:A
Category Parking Precedence 5 Year 1 Cost with GC (30%): $910
METRO STATION PAGE FACILITIES
737 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-75
Facility: Metro Station
Deficiency:
Code References:
11B-208.2
One access space in every six access spaces (or portion of 6) is not van accessible.
Recommended Remediation:
Parking facility shall be reconfigured to provide minimum number of van accessible stalls. For every six or fraction of six parking spaces required to be accessible, at least one shall be van accessible. The minimum 22 accessible spaces shall require 4 van accessible spaces.
Floor/Area: Site Parking
Room/Spot:
Priority: 1 Estimated Direct Cost: $1,600
Site Elements Parking
General Parking
Measurement: 13 count
208.2 Quantity: 4 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Van Stall Space Count
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $2,080 Comment #: MS-76
Facility: Metro Station
Deficiency:
Code References:
11B-208.2.4
One access space in every six access spaces (or portion of 6) is not van accessible. Only two stalls are designated as van accessible.
Recommended Remediation:
Parking facility shall be reconfigured to provide minimum number of van accessible stalls. For every six or fraction of six parking spaces required to be accessible, at least one shall be van accessible. The minimum 13 accessible spaces shall require 3 van accessible spaces.
Floor/Area: Parking Structure
Room/Spot:
Priority: 1 Estimated Direct Cost: $1,200
Site Elements Parking
General Parking
Measurement: 2 count
208.2.4 Quantity: 3 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Van Stall Space Count
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $1,560
METRO STATION PAGE FACILITIES
738 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-77
Facility: Metro Station
Deficiency:
Code References:
11B-502.7.2
Wheel stops are not provided.
Recommended Remediation:
A curb or wheel stop shall be provided if required to prevent encroachment of vehicles over the required clear width of adjacent accessible routes.
Floor/Area: Parking Structure
Room/Spot: Level 1
Priority: 1 Estimated Direct Cost: $5,200
Site Elements Parking
Accessible Stall
Measurement: 0 count
502 Quantity: 13 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Wheel Stop
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $6,760 Comment #: MS-78
Facility: Metro Station
Deficiency:
Code References:
11B-502.4
The slope of the van/car stall in any direction exceeds 1:48 (2.0%) grade.
Recommended Remediation:
Re-grade and resurface the accessible parking stall.
Accessible parking spaces and access aisles serving them shall have slopes not exceeding 1:48 in any direction.
Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted. Stall 2 of 13 Floor/Area: Parking Structure
Room/Spot: Level 1
Parking structures
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Parking
Accessible Stall
Measurement: 2.7 % grade
502.4 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Slopes
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $3,900
METRO STATION PAGE FACILITIES
739 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-79
Facility: Metro Station
Deficiency:
Code References:
11B-502.7.2
The slope of the van/car stall in any direction exceeds 1:48 (2.0%) grade.
Recommended Remediation:
Re-grade and resurface the accessible parking stall.
Accessible parking spaces and access aisles serving them shall have slopes not exceeding 1:48 in any direction.
Access aisles shall be at the same level as the parking spaces they serve. Changes in level are not permitted. Stall 4 of 13 Floor/Area: Parking Structure
Room/Spot: Level 1
Priority: 1 Estimated Direct Cost: $3,000
Site Elements Parking
Accessible Stall
Measurement: 2.4 % grade
502 Quantity: 200 SF
1991 ADAAG:
2010 ADAS:
2016 CBC:
Slopes
Severity:C
Category Parking Precedence 5 Year 1 Cost with GC (30%): $3,900 Comment #: MS-80
Facility: Metro Station
Deficiency:
Code References:
11B-502.1
The accessible car stall is less than 108 inches (9 ft) wide but is federally compliant.
Recommended Remediation:
Car parking spaces shall be 108 inches wide minimum.
ADA requires 96-inches (8 ft) minimum width. Stall 13 of 13 Floor/Area: Parking Structure
Room/Spot: Level 1
Parking structure
Priority: 5 Estimated Direct Cost: $400
Site Elements Parking
Accessible Stall
Measurement: 100 inches
502.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Width
Severity:D
Category Parking Precedence 5 Year 1 Cost with GC (30%): $520
METRO STATION PAGE FACILITIES
740 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-81
Facility: Metro Station
Deficiency:
Code References:
11B-502.1
The accessible car stall is less than 108 inches (9 ft) wide but is federally compliant.
Recommended Remediation:
Car parking spaces shall be 108 inches wide minimum.
ADA requires 96-inches (8 ft) minimum width. Stall 10 of 13 Floor/Area: Parking Structure
Room/Spot: Level 1
Parking structure
Priority: 5 Estimated Direct Cost: $400
Site Elements Parking
Accessible Stall
Measurement: 105 inches
502.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Width
Severity:D
Category Parking Precedence 5 Year 1 Cost with GC (30%): $520 Comment #: MS-82
Facility: Metro Station
Deficiency:
Code References:
11B-502.1
The accessible car stall is less than 108 inches (9 ft) wide but is federally compliant.
Recommended Remediation:
Car parking spaces shall be 108 inches wide minimum.
ADA requires 96-inches (8 ft) minimum width. Stall 9 of 13 Floor/Area: Parking Structure
Room/Spot: Level 1
Parking structure
Priority: 5 Estimated Direct Cost: $400
Site Elements Parking
Accessible Stall
Measurement: 101 inches
502.1 Quantity: 1 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Width
Severity:D
Category Parking Precedence 5 Year 1 Cost with GC (30%): $520
METRO STATION PAGE FACILITIES
741 Submittal: November 1, 2024
Facility ADA Assessment - Photo Report
City of Industry
Comment #: MS-83
Facility: Metro Station
Deficiency:
Code References:
228.3
51-75 electric vehicle charging stations (EVCS) are provided.
Recommended Remediation:
Where 51-75 electric vehicle charging stations (EVCS) are provided, 1 shall be van accessible, 2 shall be standard accessible, and 2 shall be ambulatory. There are no van accessible, standard accessible, or ambulatory EVCS provided on site. Note- facility was built in 2013- prior to evcs requirement.
Floor/Area: Site Parking
Room/Spot:
Priority: 1 Estimated Direct Cost: $2,000
Goods and Services EVCS
General
Measurement: 63 count
Quantity: 5 each
1991 ADAAG:
2010 ADAS:
2016 CBC:
Number of EVCS
Severity:A
Category EVCS Precedence 8 Year 3 Cost with GC (30%): $2,600
METRO STATION PAGE FACILITIES
742 Submittal: November 1, 2024
CITY OF INDUSTRY ADA SELF-EVALUATION/TRANSITION PLAN
APPENDIX N: RIGHT OF WAY ADA ASSESSMENT PHOTO REPORT
PAGE
743
Submittal: November 1, 2024
CITY OF INDUSTRY ADA SELF-EVALUATION/TRANSITION PLAN
APPENDIX N-1: TRANSIT STOPS
PAGE
744
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 4980 Square Inches
Estimated Cost: $747.00
Category: Dimensions Findings: Precedence: 9d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
83 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $971.10
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 4980 Square Inches
Estimated Cost: $747.00
SlopePerpendicular to
Category: Findings: Precedence: 9d
Remove and replace concrete to provide 2% slope
Measurement 2.1 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Trash Can
Measurement 38 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
VALLEY BLVD. PAGE 745 2ND AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9d
Relocate bench to behind pedestrian path.
Measurement inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.3* Noncompliant
2019 CBC: CBC 11B-810.3* Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Clear Floor Space Findings: Precedence: 9d
Relocate bench to provide clear floor space 30 inches by 48 inches.*
*due to limited public right of way a wheelchair space needs to be Width
Depth inches
inches
Recommendations:
A bench is provided but there is not an adjacent level wheel chair space minimum 48 inches deep by 30 inches wide.
Cost with GC (30%): $0.00
VALLEY BLVD PAGE 746 2ND AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Trash Can
Measurement inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Trash Can
Measurement Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD PAGE 747 2ND AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5400 Square Inches
Estimated Cost: $2,400.00
Category: Dimensions Findings: Precedence: 9d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
90 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $1,053.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $30.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Trash Can
Measurement 42 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 540 Square Inches
Estimated Cost: $81.00
Category: Dimensions Findings: Precedence: 9b
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
90 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $105.30
VALLEY BLVD. PAGE 748 7TH AVE.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate bench to behind pedestrian path.
Measurement inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 5400 Square Inches
Estimated Cost: $810.00
SlopePerpendicular to
Category: Findings: Precedence: 9b
Remove and replace concrete to provide 2% slope
Measurement 2.4 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 810.3* Noncompliant
2019 CBC: CBC 11B-810.3* Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Clear Floor Space Findings: Precedence: 9b
Relocate bench to provide clear floor space 30 inches by 48 inches.*
*due to limited public right of way a wheelchair space needs to be Width
Depth inches
inches
Recommendations:
A bench is provided but there is not an adjacent level wheel chair space minimum 48 inches deep by 30 inches wide.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 749 7TH AVE.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.4, 703.5.1 Not Applicable
2019 CBC: 11B-810.4
11B-703.5.1 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Bus Signs Findings: Precedence: 9b
Replace Bus Stop Sign
Measurement Yes or No
Recommendations:
The characters on the bus sign do not have a non-glare finish and/or provide contrast with their background.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate Trash Can
Measurement inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate Trash Can
Measurement Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 750 7TH AVE.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate Sign
Measurement inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 N/A
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
N/A
Measurement inches
Recommendations:
The sidewalk at this bus stop is less than the allowable 48 inches when measured from the back of curb.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 751 7TH AVE.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5400 Square Inches
Estimated Cost: $810.00
Category: Dimensions Findings: Precedence: 4d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
90 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $1,053.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 4d
Relocate bench to behind pedestrian path.
Measurement inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 5400 Square Inches
Estimated Cost: $810.00
SlopePerpendicular to
Category: Findings: Precedence: 4d
Remove and replace concrete to provide 2% slope
Measurement 2.2 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
COLIMA AVE PAGE 752 ALBATROSS RD
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.3* Noncompliant
2019 CBC: CBC 11B-810.3* Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Clear Floor Space Findings: Precedence: 4d
Relocate bench to provide clear floor space 30 inches by 48 inches.*
*due to limited public right of way a wheelchair space needs to be Width
Depth inches
inches
Recommendations:
A bench is provided but there is not an adjacent level wheel chair space minimum 48 inches deep by 30 inches wide.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 4d
Relocate Trash Can
Measurement inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: 0 Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 4d
Relocate Trash Can
Measurement Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
COLIMA AVE PAGE 753 ALBATROSS RD
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 4920 Square Inches
Estimated Cost: $738.00
Category: Dimensions Findings: Precedence: 4d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
82 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $959.40
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 4920 Square Inches
Estimated Cost: $738.00
SlopePerpendicular to
Category: Findings: Precedence: 4d
Remove and replace concrete to provide 2% slope
Measurement 3.3 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 4d
Relocate Trash Can
Finding Yes Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
COLIMA AVE PAGE 754 ALBATROSS RD
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 4d
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $2,400.00
Category: Dimensions Findings: Precedence: 9d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
60 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $1,053.00
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $4,600.00
SlopePerpendicular to
Category: Findings: Precedence: 9d
Remove and replace concrete to provide 2% slope
Measurement 2.6 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
VALLEY BLVD PAGE 755 ATHENS WAY
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3024 Square Inches
Estimated Cost: $453.60
Category: Dimensions Findings: Precedence: 5d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
56 inches
54 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $589.68
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 5d
Relocate bench to behind pedestrian path.
Measurement 37 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 3024 Square Inches
Estimated Cost: $453.60
SlopePerpendicular to
Category: Findings: Precedence: 5d
Remove and replace concrete to provide 2% slope
Measurement 2.9 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
GALE AVE PAGE 756 AZUSA AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 5d
Relocate Trash Can
Measurement 23 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 5d
Relocate Sign
Measurement 41 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $8,500.00
Category: Site Conditions Findings: Precedence: 5d
Relocate Street Light pole
Measurement 31 inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $11,050.00
GALE AVE PAGE 757 AZUSA AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3540 Square Inches
Estimated Cost: $531.00
Category: Dimensions Findings: Precedence: 5d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
59 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $690.30
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 5d
Relocate bench to behind pedestrian path.
Measurement 38 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 810.3* Noncompliant
2019 CBC: CBC 11B-810.3* Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Clear Floor Space Findings: Precedence: 5d
Relocate bench to provide clear floor space 30 inches by 48 inches.*
*due to limited public right of way a wheelchair space needs to be Width
Depth inches
29 inches
59 Recommendations:
A bench is provided but there is not an adjacent level wheel chair space minimum 48 inches deep by 30 inches wide.
Cost with GC (30%): $0.00
GALE AVE PAGE 758 AZUSA AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 5d
Relocate Trash Can
Measurement 25 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 5d
Relocate Trash Can
Finding Yes Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 5d
Relocate Sign
Measurement 40 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
GALE AVE PAGE 759 AZUSA AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $8,500.00
Category: Site Conditions Findings: Precedence: 5d
Relocate Street Light pole
Measurement 39 inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $11,050.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 1 Square Inches
Estimated Cost: $0.15
Category: Dimensions Findings: Precedence: 9d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
25 inches
25 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $0.20
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9d
Relocate bench to behind pedestrian path.
Measurement 0 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
AMAR DRIVE PAGE 760 BALDWIN PARK
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
Category: Dimensions Findings: Precedence: 9d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
60 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 9d
Relocate bench to behind pedestrian path.
Measurement 43 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
SlopePerpendicular to
Category: Findings: Precedence: 9d
Remove and replace concrete to provide 2% slope
Measurement 3.8 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
AMAR DRIVE PAGE 761 BALDWIN PARK
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 4980 Square Inches
Estimated Cost: $2,400.00
Category: Dimensions Findings: Precedence: 10a
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
83 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $971.10
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 4980 Square Inches
Estimated Cost: $4,600.00
SlopePerpendicular to
Category: Findings: Precedence: 10a
Remove and replace concrete to provide 2% slope
Measurement 3.1 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
7TH AVE PAGE 762 BONELLI ST
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $30.00
Category: Site Conditions Findings: Precedence: 10a
Relocate Trash Can
Measurement 33 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 2880 Square Inches
Estimated Cost: $432.00
Category: Dimensions Findings: Precedence: 12c
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
48 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $561.60
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12c
Relocate bench to behind pedestrian path.
Measurement inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 763 BOURDET AVE.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.3* Noncompliant
2019 CBC: CBC 11B-810.3* Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Clear Floor Space Findings: Precedence: 12c
Relocate bench to provide clear floor space 30 inches by 48 inches.*
*due to limited public right of way a wheelchair space needs to be Width
Depth inches
inches
Recommendations:
A bench is provided but there is not an adjacent level wheel chair space minimum 48 inches deep by 30 inches wide.
Cost with GC (30%): $0.00
2010 ADA: 810.4, 703.5.1 Not Applicable
2019 CBC: 11B-810.4
11B-703.5.1 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Bus Signs Findings: Precedence: 12c
Replace Bus Stop Sign
Measurement Yes or No
Recommendations:
The characters on the bus sign do not have a non-glare finish and/or provide contrast with their background.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12c
Relocate Trash Can
Measurement inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 764 BOURDET AVE.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12c
Relocate Trash Can
Measurement Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12c
Relocate Sign
Measurement inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12c
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 765 BOURDET AVE.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 N/A
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12c
N/A
Measurement inches
Recommendations:
The sidewalk at this bus stop is less than the allowable 48 inches when measured from the back of curb.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 4440 Square Inches
Estimated Cost: $666.00
Category: Dimensions Findings: Precedence: 3c
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
74 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $865.80
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 4440 Square Inches
Estimated Cost: $666.00
SlopePerpendicular to
Category: Findings: Precedence: 3c
Remove and replace concrete to provide 2% slope
Measurement 2.6 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
VALLEY BLVD PAGE 766 BREA CANYON RD
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 3c
Relocate Trash Can
Measurement 39 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 3c
Relocate Sign
Measurement 42 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 3c
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD PAGE 767 BREA CANYON RD
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5340 Square Inches
Estimated Cost: $801.00
Category: Dimensions Findings: Precedence: 9b
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
89 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $1,041.30
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate bench to behind pedestrian path.
Measurement inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 5340 Square Inches
Estimated Cost: $801.00
SlopePerpendicular to
Category: Findings: Precedence: 9b
Remove and replace concrete to provide 2% slope
Measurement 2.2 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 768 CALIFORNIA
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.3* Noncompliant
2019 CBC: CBC 11B-810.3* Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Clear Floor Space Findings: Precedence: 9b
Relocate bench to provide clear floor space 30 inches by 48 inches.*
*due to limited public right of way a wheelchair space needs to be Width
Depth inches
inches
Recommendations:
A bench is provided but there is not an adjacent level wheel chair space minimum 48 inches deep by 30 inches wide.
Cost with GC (30%): $0.00
2010 ADA: 810.4, 703.5.1 Not Applicable
2019 CBC: 11B-810.4
11B-703.5.1 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Bus Signs Findings: Precedence: 9b
Replace Bus Stop Sign
Measurement Yes or No
Recommendations:
The characters on the bus sign do not have a non-glare finish and/or provide contrast with their background.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate Trash Can
Measurement inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 769 CALIFORNIA
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate Trash Can
Measurement Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate Sign
Measurement inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 770 CALIFORNIA
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 N/A
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
N/A
Measurement inches
Recommendations:
The sidewalk at this bus stop is less than the allowable 48 inches when measured from the back of curb.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5400 Square Inches
Estimated Cost: $810.00
Category: Dimensions Findings: Precedence: 9b
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
90 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $1,053.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9b
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 771 CALIFORNIA
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 2820 Square Inches
Estimated Cost: $423.00
Category: Dimensions Findings: Precedence: 12c
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
47 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $549.90
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 12c
Relocate bench to behind pedestrian path.
Measurement 33 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 12c
Relocate Trash Can
Measurement 22 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
VALLEY BLVD. PAGE 772 CAMINO DE GLORIA
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 12c
Relocate Sign
Measurement 34 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12c
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 N/A
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12c
N/A
Measurement 47 inches
Recommendations:
The sidewalk at this bus stop is less than the allowable 48 inches when measured from the back of curb.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 773 CAMINO DE GLORIA
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
Category: Dimensions Findings: Precedence: 9d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
60 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $702.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 9d
Relocate bench to behind pedestrian path.
Measurement 43 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
SlopePerpendicular to
Category: Findings: Precedence: 9d
Remove and replace concrete to provide 2% slope
Measurement 2.1 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
AMAR RD. PAGE 774 CANAL PLACE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Trash Can
Measurement 34 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Trash Can
Finding Yes Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Sign
Measurement 41 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
AMAR RD. PAGE 775 CANAL PLACE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 9d
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5100 Square Inches
Estimated Cost: $2,400.00
Category: Dimensions Findings: Precedence: 10a
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
85 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $994.50
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
Category: Dimensions Findings: Precedence: 12d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
60 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $702.00
VALLEY BLVD PAGE 776 CLUBHOUSE DR
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 12d
Relocate bench to behind pedestrian path.
Measurement 36 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 810.4, 703.5.1 Not Applicable
2019 CBC: 11B-810.4
11B-703.5.1 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Bus Signs Findings: Precedence: 12d
Replace Bus Stop Sign
Measurement Yes or No
Recommendations:
The characters on the bus sign do not have a non-glare finish and/or provide contrast with their background.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 12d
Relocate Trash Can
Measurement 28 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
VALLEY BLVD PAGE 777 CLUBHOUSE DR
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12d
Relocate Sign
Measurement inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $8,500.00
Category: Site Conditions Findings: Precedence: 12d
Relocate Street Light pole
Measurement 36 inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $11,050.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
Category: Dimensions Findings: Precedence: 11b
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
60 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $702.00
CROSSROADS PKWY. N PAGE 778 CROSSROADS PKWY. S
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 11b
Relocate bench to behind pedestrian path.
Measurement 40 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
SlopePerpendicular to
Category: Findings: Precedence: 11b
Remove and replace concrete to provide 2% slope
Measurement 3.1 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 11b
Relocate Trash Can
Measurement inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
CROSSROADS PKWY. N PAGE 779 CROSSROADS PKWY. S
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 11b
Relocate Trash Can
Measurement Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 11b
Relocate Sign
Measurement 36 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 11b
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
CROSSROADS PKWY. N PAGE 780 CROSSROADS PKWY. S
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 4620 Square Inches
Estimated Cost: $2,400.00
Category: Dimensions Findings: Precedence: 10d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
77 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $900.90
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $30.00
Category: Site Conditions Findings: Precedence: 10d
Relocate Trash Can
Measurement 42 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 4320 Square Inches
Estimated Cost: $2,400.00
Category: Dimensions Findings: Precedence: 10c
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
72 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $842.40
7TH AVE PAGE 781 DON JULIAN RD
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $1,800.00
Category: Site Conditions Findings: Precedence: 10c
Relocate bench to behind pedestrian path.
Measurement 44 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 4320 Square Inches
Estimated Cost: $4,600.00
SlopePerpendicular to
Category: Findings: Precedence: 10c
Remove and replace concrete to provide 2% slope
Measurement 3.3 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $30.00
Category: Site Conditions Findings: Precedence: 10c
Relocate Trash Can
Measurement 30 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
7TH AVE PAGE 782 DON JULIAN RD
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 4680 Square Inches
Estimated Cost: $2,400.00
Category: Dimensions Findings: Precedence: 10d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
78 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $912.60
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 4680 Square Inches
Estimated Cost: $4,600.00
SlopePerpendicular to
Category: Findings: Precedence: 10d
Remove and replace concrete to provide 2% slope
Measurement 2.1 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5400 Square Inches
Estimated Cost: $810.00
Category: Dimensions Findings: Precedence: 1a
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
90 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $1,053.00
HACIENDA BLVD. PAGE 783 DON JULIAN RD.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 1a
Relocate Trash Can
Finding Yes Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 1a
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 4920 Square Inches
Estimated Cost: $738.00
Category: Dimensions Findings: Precedence: 1c
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
82 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $959.40
VALLEY BLVD. PAGE 784 EL ENCANTO RD.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 1c
Relocate bench to behind pedestrian path.
Measurement inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.3* Noncompliant
2019 CBC: CBC 11B-810.3* Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Clear Floor Space Findings: Precedence: 1c
Relocate bench to provide clear floor space 30 inches by 48 inches.*
*due to limited public right of way a wheelchair space needs to be Width
Depth inches
inches
Recommendations:
A bench is provided but there is not an adjacent level wheel chair space minimum 48 inches deep by 30 inches wide.
Cost with GC (30%): $0.00
2010 ADA: 810.4, 703.5.1 Not Applicable
2019 CBC: 11B-810.4
11B-703.5.1 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Bus Signs Findings: Precedence: 1c
Replace Bus Stop Sign
Measurement Yes or No
Recommendations:
The characters on the bus sign do not have a non-glare finish and/or provide contrast with their background.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 785 EL ENCANTO RD.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 1c
Relocate Trash Can
Measurement inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 1c
Relocate Trash Can
Measurement Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 1c
Relocate Sign
Measurement inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 786 EL ENCANTO RD.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 1c
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 N/A
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 1c
N/A
Measurement inches
Recommendations:
The sidewalk at this bus stop is less than the allowable 48 inches when measured from the back of curb.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 2820 Square Inches
Estimated Cost: $423.00
Category: Dimensions Findings: Precedence: 12c
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
47 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $549.90
VALLEY BLVD PAGE 787 FAIRWAY DR
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: Square Inches
Estimated Cost: $0.00
Category: Dimensions Findings: Precedence: 12c
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
inches
Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12c
Relocate bench to behind pedestrian path.
Measurement 32 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.3* Noncompliant
2019 CBC: CBC 11B-810.3* Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Clear Floor Space Findings: Precedence: 12c
Relocate bench to provide clear floor space 30 inches by 48 inches.*
*due to limited public right of way a wheelchair space needs to be Width
Depth inches
30 inches
46 Recommendations:
A bench is provided but there is not an adjacent level wheel chair space minimum 48 inches deep by 30 inches wide.
Cost with GC (30%): $0.00
VALLEY BLVD PAGE 788 FAIRWAY DR
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.4, 703.5.1 Not Applicable
2019 CBC: 11B-810.4
11B-703.5.1 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Bus Signs Findings: Precedence: 12c
Replace Bus Stop Sign
Measurement Yes or No
Recommendations:
The characters on the bus sign do not have a non-glare finish and/or provide contrast with their background.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 12c
Relocate Trash Can
Measurement 25 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 12c
Relocate Sign
Measurement 34 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD PAGE 789 FAIRWAY DR
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $8,500.00
Category: Site Conditions Findings: Precedence: 12c
Relocate Street Light pole
Measurement 33.5 inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $11,050.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 N/A
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12c
N/A
Measurement 47 inches
Recommendations:
The sidewalk at this bus stop is less than the allowable 48 inches when measured from the back of curb.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
Category: Dimensions Findings: Precedence: 12d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
60 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $702.00
VALLEY BLVD PAGE 790 FAIRWAY DR
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 12d
Relocate bench to behind pedestrian path.
Measurement 36 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 810.4, 703.5.1 Not Applicable
2019 CBC: 11B-810.4
11B-703.5.1 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Bus Signs Findings: Precedence: 12d
Replace Bus Stop Sign
Measurement Yes or No
Recommendations:
The characters on the bus sign do not have a non-glare finish and/or provide contrast with their background.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 12d
Relocate Trash Can
Measurement 13.5 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
VALLEY BLVD PAGE 791 FAIRWAY DR
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12d
Relocate Sign
Measurement inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $8,500.00
Category: Site Conditions Findings: Precedence: 12d
Relocate Street Light pole
Measurement 35 inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $11,050.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 2491 Square Inches
Estimated Cost: $373.65
Category: Dimensions Findings: Precedence: 5a
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
47 inches
53 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $485.75
VALLEY BLVD. PAGE 792 FERRERO LN.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 2491 Square Inches
Estimated Cost: $373.65
SlopePerpendicular to
Category: Findings: Precedence: 5a
Remove and replace concrete to provide 2% slope
Measurement 2.4 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 5a
Relocate Trash Can
Measurement 41 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 5a
Relocate Sign
Measurement inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
VALLEY BLVD. PAGE 793 FERRERO LN.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 5a
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 N/A
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 5a
N/A
Measurement 47 inches
Recommendations:
The sidewalk at this bus stop is less than the allowable 48 inches when measured from the back of curb.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
Category: Dimensions Findings: Precedence: 5c
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
60 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $702.00
GALE AVE PAGE 794 FIELDGATE AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 5c
Relocate bench to behind pedestrian path.
Measurement 44 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
SlopePerpendicular to
Category: Findings: Precedence: 5c
Remove and replace concrete to provide 2% slope
Measurement 3.8 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 5c
Relocate Trash Can
Measurement 28 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
GALE AVE PAGE 795 FIELDGATE AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 5c
Relocate Trash Can
Finding Yes Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 5c
Relocate Sign
Measurement 37 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 5c
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
GALE AVE PAGE 796 FIELDGATE AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
Category: Dimensions Findings: Precedence: 5b
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
60 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $702.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 5b
Relocate bench to behind pedestrian path.
Measurement 43 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
SlopePerpendicular to
Category: Findings: Precedence: 5b
Remove and replace concrete to provide 2% slope
Measurement 4.7 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
GALE AVE PAGE 797 FIELDGATE AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 5b
Relocate Trash Can
Measurement 39 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 5b
Relocate Trash Can
Finding Yes Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 5b
Relocate Sign
Measurement 39 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
GALE AVE PAGE 798 FIELDGATE AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 5b
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
Category: Dimensions Findings: Precedence: 13b
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
60 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $702.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 13b
Relocate bench to behind pedestrian path.
Measurement 38 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
VALLEY BLVD. PAGE 799 FULLERTON RD.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 13b
Relocate Trash Can
Measurement 22 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 13b
Relocate Sign
Measurement 37 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $8,500.00
Category: Site Conditions Findings: Precedence: 13b
Relocate Street Light pole
Measurement 37 inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $11,050.00
VALLEY BLVD. PAGE 800 FULLERTON RD.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5280 Square Inches
Estimated Cost: $792.00
Category: Dimensions Findings: Precedence: 2a
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
88 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $1,029.60
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 2a
Relocate Trash Can
Measurement 38 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5040 Square Inches
Estimated Cost: $756.00
Category: Dimensions Findings: Precedence: 4a
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
84 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $982.80
AZUSA AVE PAGE 801 GALE AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 4a
Relocate Trash Can
Measurement 44 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5400 Square Inches
Estimated Cost: $810.00
Category: Dimensions Findings: Precedence: 4a
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
90 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $1,053.00
2010 ADA: 810.4, 703.5.1 Not Applicable
2019 CBC: 11B-810.4
11B-703.5.1 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Bus Signs Findings: Precedence: 4a
Replace Bus Stop Sign
Finding No Yes or No
Recommendations:
The characters on the bus sign do not have a non-glare finish and/or provide contrast with their background.
Cost with GC (30%): $234.00
AZUSA AVE PAGE 802 GALE AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 4a
Relocate Trash Can
Finding Yes Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 4a
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5340 Square Inches
Estimated Cost: $801.00
Category: Dimensions Findings: Precedence: 12d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
89 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $1,041.30
NOGALES ST PAGE 803 GALE AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12d
Relocate bench to behind pedestrian path.
Measurement inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.3* Noncompliant
2019 CBC: CBC 11B-810.3* Noncompliant
Quantity: 0 Each
Estimated Cost: $0.00
Category: Clear Floor Space Findings: Precedence: 12d
Relocate bench to provide clear floor space 30 inches by 48 inches.*
*due to limited public right of way a wheelchair space needs to be Width
Depth inches
inches
Recommendations:
A bench is provided but there is not an adjacent level wheel chair space minimum 48 inches deep by 30 inches wide.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12d
Relocate Trash Can
Measurement inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
NOGALES ST PAGE 804 GALE AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: 0 Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12d
Relocate Trash Can
Measurement Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 0 Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 12d
Relocate Sign
Measurement inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 5340 Square Inches
Estimated Cost: $801.00
Category: Dimensions Findings: Precedence: 1d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
89 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $1,041.30
GALE AVE. PAGE 805 GATLIN AVE.
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 5340 Square Inches
Estimated Cost: $801.00
SlopePerpendicular to
Category: Findings: Precedence: 1d
Remove and replace concrete to provide 2% slope
Measurement 3 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 1d
Relocate Street Light pole
Measurement inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3120 Square Inches
Estimated Cost: $468.00
Category: Dimensions Findings: Precedence: 13c
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
52 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $608.40
VALLEY BLVD PAGE 806 GIANO AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $105.00
Category: Site Conditions Findings: Precedence: 13c
Relocate bench to behind pedestrian path.
Measurement 37 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
2010 ADA: 810.4, 703.5.1 Not Applicable
2019 CBC: 11B-810.4
11B-703.5.1 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Bus Signs Findings: Precedence: 13c
Replace Bus Stop Sign
Measurement Yes or No
Recommendations:
The characters on the bus sign do not have a non-glare finish and/or provide contrast with their background.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $15.00
Category: Site Conditions Findings: Precedence: 13c
Relocate Trash Can
Measurement 28 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
VALLEY BLVD PAGE 807 GIANO AVE
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 13c
Relocate Sign
Measurement 46 inches
Recommendations:
The bus stop sign blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $8,500.00
Category: Site Conditions Findings: Precedence: 13c
Relocate Street Light pole
Measurement 38 inches
Recommendations:
The street light pole blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $11,050.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $1,800.00
Category: Site Conditions Findings: Precedence: 1a
Relocate bench to behind pedestrian path.
Measurement 25 inches
Recommendations:
The provided bench blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $136.50
STAFFORD ST PAGE 808 GLENDORA AVE/SOTRO ST
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 5760 Square Inches
Estimated Cost: $4,600.00
SlopePerpendicular to
Category: Findings: Precedence: 1a
Remove and replace concrete to provide 2% slope
Measurement 7.8 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $30.00
Category: Site Conditions Findings: Precedence: 1a
Relocate Trash Can
Measurement 9 inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $19.50
2010 ADA: 810.2.2 Noncompliant
2019 CBC: CBC 11B-810.2.2 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
Category: Dimensions Findings: Precedence: 5d
Widen sidewalk to expand boarding area to 8 feet deep by 5 feet wide.
Width
Depth inches
60 inches
60 Recommendations:
The boarding and alighted does not provide a firm, stable and slip-resistant area minimum 96 inches deep by 60 inches wide.
Cost with GC (30%): $702.00
GALE AVE PAGE 809 GREEN DR
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 810.2.4 Noncompliant
2019 CBC: CBC 11B-810.2.4 Noncompliant
Quantity: 3600 Square Inches
Estimated Cost: $540.00
SlopePerpendicular to
Category: Findings: Precedence: 5d
Remove and replace concrete to provide 2% slope
Measurement 2.7 Percent
Recommendations:
The slope, perpendicular to the roadway, of the boarding and alighted area exceeds the allowable 2.0% grade.
Cost with GC (30%): $0.00
2010 ADA: 403.5.1 Noncompliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 5d
Relocate Trash Can
Measurement inches
Recommendations:
The provided trash receptacle blocks the accessible route so that it is less than 48 inches wide, and/or impedes the clear space of the boarding and alighted area.
Cost with GC (30%): $0.00
2010 ADA: 810.3 Not Applicable
2019 CBC: CBC 11B-810.3 Noncompliant
Quantity: Each
Estimated Cost: $0.00
Category: Site Conditions Findings: Precedence: 5d
Relocate Trash Can
Measurement Yes or No
Recommendations:
The provided trash receptacle is located within designated wheelchair space.
Cost with GC (30%): $0.00
GALE AVE PAGE 810 GREEN DR
Submittal: November 1, 2024
Transit Stops ADA Assessment - Photo Report
2010 ADA: 403.5.1 Compliant
2019 CBC: CBC 11B-403.5.1 Exception 3 Noncompliant
Quantity: 1 Each
Estimated Cost: $180.00
Category: Site Conditions Findings: Precedence: 5d
Relocate Sign
Measurement 44 inches
Recommendations: