Chapter 7.32
BUILDING CODE
Sections:
7.32.010 Title.
7.32.020 Purpose.
7.32.030 Adoption of Building Codes.
7.32.040 Scope.
7.32.050 Exceptions.
7.32.060 Additions, alterations and repairs-Generally.
7.32.070 Additions, alterations and repairs-Code compliance.
7.32.080 Alterations and repairs-Apartment houses, hotels and dwellings.
7.32.090 Additions-Apartment houses, hotels and dwellings.
7.32.100 Repair of roof covering.
7.32.110 Chapter 1 Division II, Administration-Deleted.
7.32.120 Section 202, Chapter 2, Definitions of Substantial Damage and Substantial Improvement.
7.32.130 Section502.2.1, 502.2.2, 502.2.3, 502.2.4, Chapter 5, Address illumination.
7.32.140 Section 507.14, Chapter 5, Front Restriction-Added.
7.32.150 Section 706.1, Chapter 7, Fire walls-Amended.
7.32.160 Section 701A.1, Chapter 7A, Scope-Amended.
7.32.170 Section 702A, Chapter 7A, Definitions-Amended.
7.32.180 Sections 903.2 Exception, 903.2.1.2#4, 903.2.1.3#4, 903.2.3#2 Exception, 903.2.3#5, 903.2.4#2, 903.2.4#3, 903.2.7#2, 903.2.7#3, 902.2.7#4, 903.2.7.2, 903.2.9#3, 903.2.9#4, 903.2.9.1, 903.2.10, and 903.2.10.1 – Deleted; 903.2.1.1#1, 903.2.1.2#1, 903.2.1.3#1. 903.2.1.4#1, 903.2.3#1, 903.2.4, 903.2.4#1, 903.2.7#1, 903.2.9, 903.2.9#1, 903.2.9#2, and 903.2.11.3 Amended; and 903.2.13 and 903.2.30 -Added.
7.32.190 Section 1505.1, Chapter 15, Fire Classification-Amended.
7.32.200 Table 1607.1, Chapter 16, Minimum Uniformly Distributed Live Loads, Lo, and Minimum Concentrated Live Loads -Amended.
7.32.210 Section 1705.3, Exception 1, Chapter 17, Concrete Construction – Amended.
7.32.220 Section 1905.1.7, Chapter 19, ACI 318, Section 14.1.4-Amended.
7.32.230 Table 2308.6.1, Chapter 23, Wall Bracing RequirementsAmended.
7.32.240 Section 2308.6.9, Attachment of Sheathing-Amended.
7.32.250 Section 3115.1, Chapter 31, Prohibited Installations-Added.
7.32.260 Section 3203, Chapter 32, Signs-Added.
7.32.270 Section H101.2, Signs exempt from permits -Deleted.
7.32.280 Section 1010, Appendix Chapter 10, Building security – Added.
7.32.290 Section G101.4, Chapter Appendix G, Violations-Amended. 1818
7.32.300 Section G101.5, Chapter Appendix G, Designation of floodplain administrator-Amended.
7.32.010 Title.
The building codes adopted by section 7.32.030 and the provisions of this Chapter shall constitute the Dublin Building Code and may be referred to as such.
7.32.020 Purpose.
The promotion and preservation of the public health, safety and general welfare of the people of the City and the property situated therein have made necessary the adoption of the building codes referred to in Section 7.32.030 in order to adequately safeguard life, health, property, and general welfare. The purpose of this Code is not to create or otherwise establish or designate any particular class or groups of persons who will or should be especially protected or benefited by the terms of this Code.
7.32.030 Adoption of Building Codes.
A. The 2022 California Building Code, Part 2, Title 24 of the California Code of Regulations, a portion of the California Building Standards Code, as defined in the California Health and Safety Code Section 18901 et. seq. (hereinafter referred to as the "State Code"), and any rules and regulations promulgated pursuant thereto including the International Building Code, 2021 Edition, including Appendix Chapters, C, F, G, H, and I, , as published by the International Code Council, and as referenced in and adopted pursuant to California Health and Safety Code Sections 17922 and 18935, (hereinafter referred to as the "IBC") are hereby adopted and incorporated by reference herein.
The codes and standards referenced in this code shall be considered part of this code to the prescribed extent of each such reference. Where the extent of the reference to a referenced code or standard includes subject matter that is within the scope of this code or the Mechanical, Plumbing, Housing, Fire or Energy Codes, the provisions of these codes as applicable, shall take precedence over the provisions in the referenced code or standard.
Copies of the adopted codes have been and are now filed in the Office of the Building Official, 100 Civic Plaza, Dublin, California, for use and examination by the public. Said codes are adopted by reference pursuant to Section 50022.4, et seq., of the Government Code of the State of California, and the codes are hereby adopted and incorporated as fully as if set out at length herein, and from the date on which this Ordinance shall take effect, the provisions thereof shall be controlling within the limits of the City of Dublin.
1819
B. Notwithstanding the provisions of Section 7.32.030.A, the State Code and the International Building Code are amended as set forth in Sections 7.32.110 through 7.32.300.
7.32.040 Scope.
A. The provisions of this Code shall apply to the installation, erection, construction, enlargement, addition to, alteration, repair, relocation, removal, demolition, conversion, replacement, equipment, use and occupancy, location, replacement, and maintenance of every building or structure or any appurtenances connected or attached to such buildings or structures within the City.
B. The permissive provision of this Code shall not be presumed to waive any limitations imposed by any other law, ordinance, rule, or regulation. If two or more pertinent limitations are not identical, those limitations shall prevail which provide greater safety to life, health, property, or public welfare.
C. Buildings shall be made accessible to persons with disabilities as required by Title 24 California Code of Regulation. Whenever there is a conflict between the provisions of this Code and Title 24, California Code of Regulations with respect to the accessibility of buildings to persons with disabled, the provisions of Title 24 shall prevail.
7.32.050 Exceptions.
The provisions of this Code shall not apply to:
A. Work located in a public street;
B. Trailer coaches, campers, mobile homes, motor vehicles, railroad cars, and aircraft; however, if any of the foregoing are permanently placed on the ground or have their wheels removed for other than temporary repairs, they shall comply with all of the provisions of this Code;
C. Houseboats or other watercraft; however, if any of the forgoing are stored out of the water and are used for any purpose whatsoever, they shall comply with all of the provisions of this Chapter;
D. Towers or poles supporting communication lines or power transmission lines;
E. Dams, flood control and drainage structures;
F. Portable amusement devices and structures, including merry-go-rounds, ferris wheels, rotating conveyances, slides, similar devices, and portable accessory structures whose use is necessary for the operation of such amusement devices and structures but not including any storage building or detached structure which is not an integral part of the device.
G. Detached one- and two-family dwellings and townhouses not more than three stories above grade plane in height with a separate means of egress, and their accessory structures not more than three stories above grade plane in height, shall comply with this code or the Residential Code.
7.32.060 Additions, alterations and repairs-Generally.
1820
Buildings or structures to which additions, alterations, or repairs are made shall comply with all the requirements of this Code for new buildings or structures except as specifically provided for in this section and Sections 7.32.070 through
7.32.100.
7.32.070 Additions, alterations and repairs-Code compliance.
Additions, alterations or repairs may be made to any building or structure without requiring the existing building or structure to comply with all the requirements of this Code, provided the addition, alteration or repair conforms to that required for a new building or structure. Additions or alterations shall not be made to an existing building or structure which will cause the existing building or structure to be in violation of any of the provisions of this Code nor shall such additions or alterations cause the existing building or structure to become unsafe.
An unsafe condition shall be deemed to have been created if an addition or alteration will cause the existing building or structure to become structurally unsafe or overloaded; will not provide adequate egress in compliance with the provisions of this Code or will obstruct existing exits; will create a fire hazard; will reduce required fire resistance or will otherwise create conditions dangerous to human life. Any building so altered, which involves a change in use or occupancy, shall not exceed the height, number of stories and area permitted for new buildings. Any building plus new additions shall not exceed the height, number of stories and area specified for new buildings. Additions or alterations shall not be made to an existing building or structure when such existing building or structure is not in full compliance with the provision of this Code.
7.32.080 Alterations and repairs-Apartment houses, hotels and dwellings.
A. The provisions of Section 7.32.070 shall not prohibit the alteration or repair of any legally established existing apartment house, hotel, dwelling or structure accessory thereto which retains, replaces or extends the use of the original materials or continued use of original methods of construction provided such alteration or repair does not create or continue a dangerous building as defined in Section 7.28.220, a substandard building as defined in Section 7.28.090 of the Dublin Municipal Code. However, such alteration or repair shall not reduce any required fire resistance below that specified by this Code, reduce the resistance to lateral forces below that specified by this Code, or increase the stress or deflection of any member so as to exceed that specified by this Code.
B. The provisions of Section 7.32.070 pertaining to additions shall not require any legally existing apartment house, hotel, dwelling, or structure accessory thereto to be made to conform to the provisions of this Code solely because of the construction of the addition. However, this section shall not be constructed to permit the addition to increase the stress or deflection of any existing member so as to exceed that specified by the building code. Whenever an addition increases the number of occupants which must exit through the existing building all of the exit facilities serving the increased number of occupants shall comply with the provisions of this Code.
1821
C. Whenever a new dwelling unit is created either by new construction, or by an alteration to an existing building, separate gas and electrical meters shall be provided.
7.32.090 Additions-Apartment houses, hotels and dwellings.
Notwithstanding the provisions of Section 7.28.240 whenever alterations, repairs, or additions requiring a permit or one (1) or more sleeping rooms are added or created in existing Group R Occupancies, the entire building shall be provided with smoke alarms and carbon monoxide alarms located as required for new Group R Occupancies.
Furthermore, spark arrestors shall be installed on all chimneys connected to solid burning fuel-burning appliances.
7.32.100 Repair of roof covering.
Roof coverings may be repaired or replaced with materials as set forth in Section 7.32.190.
7.32.110 Chapter 1 Division II, Administration-Deleted.
Chapter 1 Division II is deleted.
7.32.120 Section 202, Chapter 2, Definitions of Substantial Damage and Substantial Improvement – Added.
The definitions of “Substantial Damage” and “Substantial Improvement” in Section 202 of the State Code are amended to read as follows:
Substantial Damage. Damage of any origin sustained by a structure whereby the cost of restoring the structure to its before-damaged condition would equal or exceed 50 percent of the market value of the structure before the damage occurred. The term also includes flood-related damage sustained by a structure on two separate occasions during a 10-year period for which the cost of repairs at the time of each such flood event, on average, equals or exceeds 25 percent of the market value of the structure before the damage occurred.
Substantial Improvement. Any one or more or any combination of repair, reconstruction, rehabilitation, alterations, addition or other improvement of a building or structure taking place during a 10-year period, the cumulative cost of which equals or exceeds 50 percent of the market value of the structure before the improvement or repair is started. For each building or structure, the 10-year period begins on the date of the first permit issued for improvement or repair of that building or structure subsequent to January 1, 2023. If the structure has sustained substantial damage, any repairs are considered substantial improvement regardless of the actual repair work performed. The term does not, however, included either:
1822
1. Any project for improvement of a building required to correct existing health, sanitary or safety code violations identified by the building official and that are the minimum necessary to assure safe living conditions.
2. Any alteration of a historic structure provided that the alteration will not preclude the structure’s continued designation as a historic structure.
7.32.130 Sections 502.2.1, 502.2.2, 502.2.3, 502.2.4, Chapter 5, Address illumination – Added.
Sections 502.2.1, 502.2.2, 502.2.3, 502.2.4 are added to read:
502.2.1 The address number(s) shall be illuminated during the hours of darkness. The light source shall be provided with an uninterruptible AC power source or controlled by a photoelectric device.
502.2.2 Exterior doors in commercial tenant space numbers shall be addressed as required in section 502.1. Exception, dual doors may have the addresses on one door or centered above the doors. In addition, all rear doors or service doors will have the name of the business in 4-inchhigh lettering. 502.2.3 No other number may be affixed to a structure that might be mistaken for, or confused with, the number assigned to the structure. 502.2.4 The assigned address, including the suite number, shall be displayed on all electric meters in accordance with utility company standards.
7.32.140 Section 507.14, Chapter 5, Frontage Restriction-Added.
A new Section 507.14 is added to read:
507.14 Frontage Restriction. The increase in area permitted by Sections 506.3, 507.1 through 507.13 of this Section shall not be allowed unless or until the owner of the required yard shall file an agreement binding such owner, his heirs, and assignees, to set aside the required yard as unobstructed space having no improvements. Such agreement shall be recorded in the Alameda County Recorder's Office.
Exception: When using the public way for frontage increase.
7.32.150 Section 706.1, Chapter 7, Fire Walls-Amended.
Section 706.1 is amended by adding a new subsection 706.1.2 to read:
1823
706.1.2 Fire walls shall not be considered to create separate buildings for the purpose of automatic fire-sprinkler system requirements as set forth in Chapter 9.
7.32.160 Section 701A.1, Chapter 7A, Scope-Amended.
Section 701A.1 is amended to read:
701A.1 Scope. This Chapter applies to building materials, systems and/or assemblies used in the exterior design and construction of new buildings located within a Wildland-Urban Interface (WUI) Fire Area as defined in Section 702A or adjacent to open space or undeveloped land.
7.32.170 Section 702A, Chapter 7A, Definitions-Amended.
Section 702A is amended to add the following definitions:
Adjacent to Open Space. Shall mean commercial parcels and residential lots which have a point of contact with open space.
Adjacent to Undeveloped Land. Shall mean commercial parcels and residential lots which have a point of contact with Undeveloped Land.
Open Space. For the purpose of this Chapter, Open Space shall mean those lands set aside to remain permanently undeveloped.
Undeveloped Land. For the purpose of this Chapter, Undeveloped Land shall mean land which is available for development, but no Tentative Map, Master Tentative Map or Development Agreement has been approved, and any land designated for government use for which no development plan has been approved.
7.32.180 Sections 903.2 Exception, 903.2.1.2#4, 903.2.1.3#4, 903.2.3#2 Exception, 903.2.3#5, 903.2.4#2, 903.2.4#3, 903.2.7#2, 903.2.7#3, 902.2.7#4, 903.2.7.2, 903.2.9#3, 903.2.9#4, 903.2.9.1, 903.2.10, and 903.2.10.1 – Deleted; 903.2.1.1#1, 903.2.1.2#1, 903.2.1.3#1. 903.2.1.4#1, 903.2.3#1, 903.2.4, 903.2.4#1, 903.2.7#1, 903.2.9, 903.2.9#1, 903.2.9#2, and 903.2.11.3 Amended; and 903.2.13 and 903.2.30 -Added.
Sections 903.2 Exception, 903.2.1.2#4, 903.2.1.3#4, 903.2.3#2 Exception, 903.2.3#5, 903.2.4#2, 903.2.4#3, 903.2.7#2, 903.2.7#3, 902.2.7#4, 903.2.7.2, 903.2.9#3, 903.2.9#4, 903.2.9.1, 903.2.10, and 903.2.10.1 are deleted; Sections 903.2.1.1#1, 903.2.1.2#1, 903.2.1.3#1. 903.2.1.4#1, 903.2.3#1, 903.2.4, 903.2.4#1, 903.2.7#1, 903.2.9, 903.2.9#1, 903.2.9#2, and 903.2.11, are amended to read as follows; and Sections 903.2.13 and 903.2.30 are added to read as follows:
1824
903.2.1.1 Group A-1 Occupancies.
1. The fire area exceeds 3,000 square feet (279 m²).
903.2.1.2 Group A-2 Occupancies.
1. The fire area exceeds 3,000 square feet (279 m²).
903.2.1.3 Group A-3 Occupancies.
1. The fire area exceeds 3,000 square feet (279 m²).
903.2.1.4 Group A-4 Occupancies.
1. The fire area exceeds 3,000 square feet (279 m²).
903.2.3 Group E Occupancies.
1. Throughout all Group E fire areas greater than 3,000 square feet (279 m²).
903.2.4 Group F Occupancies.
An automatic sprinkler system shall be provided throughout all buildings containing a Group F occupancy where one of the following conditions exists:
1. A Group F fire area exceeds 2,500 square feet (232 m²). 903.2.7 Group M Occupancies.
1. A Group M fire area exceeds 2,500 square feet (232 m²). 903.2.9 Group S Occupancies.
An automatic sprinkler system shall be installed in all Group S occupancies as follows:
1. The fire area exceeds 2,500 square feet (232 m²);
2. Buildings with repair garages servicing vehicles parked in basements.
903.2.11.3 Buildings Three Or More Stories in Height.
An automatic sprinkler system shall be installed in all occupancies, regardless of type of construction, if the building is three or more stories or more than 35 feet in height measured from the pad grade level to the highest point of the building. An automatic sprinkler system shall be installed in all other occupancies as may be required by the 2022 California Building and Residential Code.
903.2.13 Group B Occupancies.
An automatic fire-extinguishing system shall be installed in Group B occupancies where the floor area exceeds 3,000 square feet (279 m²).
1825
903.2.30 All Occupancies.
An automatic fire-extinguishing system shall be installed in all occupancies located more than one and one half (1½) miles from a fire station providing fire protection to that location. Said distance shall be measured in a straight line.
Buildings containing portions which are required to have an automatic fire extinguishing system because of the number of stories shall have the automatic fire extinguishing system installed throughout and fire walls as set forth in Section 706 shall not be considered as creating separate buildings for the purpose of this section.
Whenever an addition is made to an existing building, automatic fireextinguishing systems shall be installed if the existing building plus the addition exceeds the area or height limitations set forth in this section.
Whenever the use of an existing building or portion thereof is changed in any manner so as to require the installation of an automatic fireextinguishing system, said system shall be installed in that portion of the building housing the new use.
(Sections 903.2 Exception, 903.2.1.2#4, 903.2.1.3#4, 903.2.3#2 Exception, 903.2.3#5, 903.2.4#2, 903.2.4#3, 903.2.7#2, 903.2.7#3, 902.2.7#4, 903.2.7.2, 903.2.9#3, 903.2.9#4, 903.2.9.1, 903.2.10, and 903.2.10.1 are deleted)
7.32.190 Section 1505.1, Chapter 15, Fire Classification-Amended.
Section 1505.1 is amended to read:
1505.1 General. Roof Assemblies shall be divided into the classes defined below. Class A, B, and C roof assemblies and roof coverings required to be listed by this section shall be tested in accordance with ASTM E 108 or UL 790. In addition, fire-retardant-treated wood roof coverings shall be tested in accordance with ASTM D 2898. The minimum roof coverings installed on buildings shall comply with the following:
1. Map of Fire Safe Roof Areas. Figure 15-1* is a map of Fire Safe Roof
areas. Said map may be amended from time to time by including areas which are
annexed to the City within one of the two roofing areas. Said amendments may be
made by the Building Official after consultation, with the Chief of the Fire Department having jurisdiction.
1826
2. Roofing Area 1. Any new roof and any alteration, repair or replacement for
buildings housing R & U occupancies in Roofing Area 1 shall use roof covering
material that conforms to Class B or better or shall be made of concrete, ferrous or copper metal, clay, slate or similar non-combustible material.
3. Roofing Area 2. Any new roof for buildings using roof covering material
that conforms to Class C or better or shall be made of concrete, ferrous or copper metal, clay, slate or similar non-combustible material.
4. Other Occupancies. Any new roof covering and any alterations, repairs or
replacement of roof covering material for buildings housing all other occupancies
shall conform to the requirements as set forth in Roofing Area 1. * Editor's Note: Figure 15-1 is on file in the office of the City Clerk.
7.32.200 Table 1607.1, Chapter 16, Minimum Uniformly Distributed Live Loads, Lo, and Minimum Concentrated Live Loads -Amended.
Table 1607.1 is amended by adding a new Footnote e to read:
e. Bridges for vehicular traffic shall be designed for H20 loading as designated by the American Association of State Highway Officials.
7.32.210 Section 1705.3 Exception 1, Chapter 17, Concrete Construction – Amended.
Section, 1705.3 Exception 1 is amended to read:
1. Isolated spread concrete footings of buildings three stories or less above grade plane that are fully supported on earth or rock, where the structural design of the footing is based on a specified compressive strength, f’c, no greater than 2,500 pounds per square inch (psi) (17.2 Mpa) regardless of the compressive strength specified in the construction documents or used in the footing construction.
7.32.220 Section 1905.1.7, Chapter 19, ACI 318, Section 14.1.4-Amended.
Section 1905.1.7, Delete ACI 318, Section 14.1.4 and replace with the following:
14.1.4 - Plain concrete in structures assigned to Seismic Design Category C, D, E or F.
14.1.4.1- Structures assigned to Seismic Design Category C, D, E or F shall not have elements of structural plain concrete, except as follows:
1827
(a) Isolated footings of plain concrete supporting pedestals or columns are permitted, provided the projection of the footing beyond the face of the supported member does not exceed the footing thickness.
Exception:
In detached one- and two-family dwelling three stories or less in height, the projection of the footing beyond the face of the supported member is permitted to exceed the footing thickness. (b) Plain concrete footing supporting walls are permitted, provided the footings have at least two continuous longitudinal reinforcing bars.
Bars shall not be smaller than No. 4 and shall have a total area of not less than 0.002 times the gross cross-sectional area of the footing. A minimum of one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement shall be provided at corners and intersections.
Exception:
In detached one- and two-family dwellings three stories or less in height and constructed with stud bearing walls, plain concrete footings with at least two continuous longitudinal reinforcing bars not smaller than No. 4 are permitted to have a total area of less than 0.002 times the gross cross –sectional area of the footing.
7.32.230 Table 2308.6.1, Chapter 23, Wall Bracing Requirements– Amended.
Table 2308.6.1 is amended by adding new footnotes “f” and “g” to read:
f. Methods PBS, HPS, and SFB are not permitted in Seismic Design Category D and E.
g. Methods GB, DWB and PCP are not permitted in Seismic Design Category E.
7.32.240 Section 2308.6.9, Attachment of Sheathing-Amended.
Section 2308.6.9, is amended by adding a second paragraph:
All braced wall panels shall extend to the roof sheathing and shall be attached to parallel roof rafters or blocking above with framing clips (18 gauge minimum) spaced at maximum 24 inches (6096 mm) on center with four 8d nails per leg (total eight 8d nails per clip). Braced wall panels shall be laterally braced at each top corner and at maximum 24 inches (6096 mm) intervals along the top plate of discontinuous vertical framing.
7.32.250 Section 3116.1, Chapter 31, Prohibited Installations-Added.
A new Section 3115.1 is added to read:
1828
3116.1 Prohibited Installations. It shall be unlawful to install a wood burning fireplace or wood burning appliance that is not one of the following:
1) Pellet-fueled wood heater,
2) EPA certified wood heater,
3) Fireplace certified by EPA
7.32.260 Section 3203, Chapter 32, Signs-Added.
A new Section 3203 is added to read:
3203 Signs. Signs when placed flat against the wall of a building shall not project beyond the front property line more than 12 inches (305mm).
7.32.270 Section H101.2, Signs exempt from permits -Deleted.
Section H101.2 is deleted.
7.32.280 Section 1010, Appendix Chapter 10, Building security – Added.
Appendix Chapter 10 is added to read:
Section 1010 building security shall be in accordance with the Uniform Building Security Code in addition to the following:
* Editor's Note: See Chapter 7.34 Residential Code for single family or townhouse requirements.
(A) Addressing. All buildings shall be addressed as follows:
(1) Walkways serving six (6) or more individual units where the front entrance is not parallel to the street and driveways servicing six (6) or more individual dwelling units shall have minimum of 4-inch-high identification numbers, noting the range of unit numbers placed at the entrance to each driveway at a height between thirty-six (36) and forty-two (42) inches above grade. The address numbers shall be illuminated during the hours of darkness. The light source shall be provided with an uninterruptible AC power source or controlled only by a photoelectric device.
(2) There shall be positioned at each street entrance of a multi- family complex having more than one structure, an illuminated diagrammatic representation (map) of the complex that shows the location of the viewer and the unit designations within the complex. It shall be lighted during the hours of darkness utilizing a light source, which is constructed of weather and vandal resistant materials and provided with an uninterruptible AC power source or controlled by a photoelectric device. Nothing in this section shall preclude the requirement for circuit protection devices where applicable. (3) If the building is adjacent to an alley, the number shall also be placed on or adjacent to the rear gate accessing the alley. Any building with vehicular 1829
access to the rear through a public or private alley shall display, in a clearly visible location, a highly reflective or illuminated address number a minimum of four (4) inches in height.
(4) Where more than one (1) building is accessed by a common street entrance or there are multiple buildings on the same lot, each principal building shall display the number or letter assigned to that building on each corner of the building, as determined by the Building Official. These numbers shall be made visible during the hours of darkness. The street name may also be required when there is a secondary street frontage.
(5) Addressing shall not be obstructed by architectural structures such as trellises, arbors, balconies, light fixtures and or landscaping. (6) In Commercial Day Care or Education facilities, all interior and exterior doors shall be provided with a room number on the door. A map of the facilities detailing location of all rooms and their uses shall be kept on file at the facilities on-site office.
(B) Exterior Openings. Exterior opening shall be as follows:
(1) Swinging exterior wood and steel doors shall be equipped as follows:
(a) A single or double door shall be equipped with a double- or singlecylinder deadbolt. The bolt shall have a minimum projection of one (1) inch and be constructed so as to repel cutting tool attack. The deadbolt shall have an embedment of at least three-fourths (3/4) inch into the strike receiving the projected bolt. The cylinder shall have a cylinder guard, a minimum of five pin tumblers and shall be connected to the inner portion of the lock by connecting screws of at least one-fourth (1/4) inch in diameter. The provisions of this paragraph do not apply where: (a) panic hardware is required, (b) conflicts with emergency egress requirements of the building and fire codes or (C) an equivalent device is approved by the authority having jurisdiction.
(b) Doorstop on a wooden jamb for an in-swing door shall be of one-piece construction with the jamb joined by a rabbet.
(c) For the purpose of this section, doors leading from garage areas into a dwelling are exterior doors.
(2) Double doors shall be equipped as follows:
(a) The inactive leaf of double door(s) shall be equipped with metal flush bolts that have a minimum embedment of five-eighths (5/8) inch into the head and threshold of the doorframe.
1830
(b) Double doors shall have an astragal constructed of steel a minimum of .125 inch thick, which will cover the opening between the doors. The astragal shall be a minimum of two (2) inches wide and extend a minimum of one (1) inch beyond the edge of the door to which it is attached. The astragal shall be attached to the outside of the active door by means of welding or with non-removable bolts spaced apart on not more than ten (10) inch centers. (The door to which such an astragal is attached must be determined by the fire safety codes adopted by the enforcing authority.) (3) Aluminum frame swinging doors shall be equipped as follows:
(a) The jamb on all aluminum frame-swinging doors shall be so constructed or protected to withstand 1,600 pounds of pressure in both a vertical distance of three (3) inches and a horizontal distance of one (1) inch each side of the strike, to prevent violation of the strike. (b) A single or double door shall be equipped with a double cylinder deadbolt with a bolt projection exceeding one (1) inch, or a hook shaped or expanding dog bolt that engages the strike sufficiently to prevent spreading. The deadbolt lock shall have a minimum of five pin tumblers and a cylinder guard.
(4) Panic hardware, whenever required by the California Building Code or Title 19, California Administration Code, shall be installed as follows:
(a) Panic hardware shall contain a minimum of two (2) locking points on each door; or
(b) On single doors, panic hardware may have one locking point, which is not to be located at either the top or bottom frame. The door shall have an astragal constructed of steel .125 inch thick, which shall be attached with non-removable pins to the outside of the door. The astragal shall extend a minimum of six (6) inches vertically above and below the latch of the panic hardware. The astragal shall be a minimum of two (2) inches wide and extend a minimum of one (1) inch beyond the edge of the door to which it is attached.
(c) Double doors containing panic hardware shall have an astragal attached to the doors at their meeting point, which will close the opening between them, but not interfere with the operation of either door. (The astragal shall not interfere with the safe operation of emergency egress). (5) Horizontal or Sliding Doors shall be installed as follows:
(a) In commercial occupancies, horizontal sliding doors shall be equipped with a metal guide track at top and bottom and a cylinder lock and/or 1831
padlock with a hardened steel shackle which locks at both heel and toe, and a minimum five pin tumbler operation with non-removable key when in an unlocked position. The bottom track shall be so designed that the door cannot be lifted from the track when the door is in a locked position. (b) In residential occupancies, locks shall be provided on all sliding patio doors. The lock bolt on all glass patio doors shall engage the strike sufficiently to prevent its being disengaged by any possible movement of the door within the space or clearance provided for installation and operation. The strike area shall be of material adequate to maintain effectiveness of bolt strength.
(c) Sliding patio glass doors opening onto patios or balconies which are less than one story above grade or are otherwise accessible from the outside shall have the moveable section of the door sliding on the inside of the fixed portion of the door or possess an approved secondary lock mounted on interior of moveable section.
(6) In office buildings (multiple occupancy), all entrance doors to individual office suites shall meet the construction and locking requirements for exterior doors.
(7) In commercial occupancies, windows shall be deemed accessible if less than twelve (12) feet above the ground. Accessible windows having a pane exceeding ninety-six (96) square inches in an area with the smallest dimension exceeding six (6) inches and not visible from a public or private thoroughfare shall be protected with burglary resistant glazing or other approved methods as determined by the Building Official.
(8) Side or rear windows of the type that can be opened shall, where applicable, be secured on the inside with either a slide bar, bolt, crossbar, auxiliary locking device, and/or padlock with a hardened steel shackle, a minimum four pin tumbler operation.
(9) Protective bars or grills shall not interfere with the operation of opening windows if such windows are required to be operable by the California Building Code.
(10) All exterior transoms exceeding ninety-six (96) square inches on the side and rear of any building or premises used for business purposes shall be protected with burglary resistant glazing or other approved methods as determined by the Building Official.
(11) Roof openings shall be equipped as follows:
1832
(a) All skylights on the roof of any building or premises used by business purposes shall be provided with:
(1) Rated burglary resistant glazing; or
(2) Iron bars of at least one-half (1/2) inch round or one by onefourth (1 x ¼) inch flat steel material under the skylight and securely fastened; or
(3) Steel grills of at least one-eighth (1/8) inch material with a maximum two (2) inches mesh under the skylight and securely fastened.
(4) A monitored intrusion alarm system. The system shall be kept operable at all times. The Chief of Police may require periodic testing of the alarm system to verify proper operation. (b) All hatchway openings on the roof of any building or premises used for business purposes shall be secured as follows:
(1) If the hatchway is of wooden material, it shall be covered on the inside with at least sixteen (16) U.S. gauge sheet metal, or its equivalent, attached with screws.
(2) The hatchway shall be secured from the inside with a slide bar or slide bolts. (Fire Department approval may be desired.) (3) Outside hinges on all hatchway openings shall be provided with non-removable pins when using pin-type hinges.
(c) All air duct or air vent openings exceeding ninety-six (96) square inches on the roof or exterior walls of any building or premises used for business purposes shall be secured by covering the same with either of the following:
(1) Iron bars of at least one-half (1/2) inch round or one by onefourth (1 x ¼) inch flat steel material spaced no more than five (5) inches apart and securely fastened; or
(2) Iron or steel grills of at least one-eighth (1/8) inch material with a maximum two (2) inch mesh and securely fastened.
(3) If the barrier is on the outside, it shall be secured with bolts which are non-removable from the exterior.
1833
(4) The above must not interfere with venting requirements creating a potentially hazardous condition to health and safety or conflict with the provisions of the California Building Code or Title 19, California Administrative Code.
(12) Exterior roof ladders shall not be permitted.
(13) Exterior electrical or phone panels are not permitted in commercial occupancies.
(14) Separation walls for individual commercial tenant spaces housed within a common structure shall be solid with sheathing and continuous from the structure's foundation to roof or floor / ceiling assembly. If both sides of the tenant spaces are accessible, then each side shall be sheathed. (15) Intrusion Devices.
(a) If the enforcing authority determines that the security measures and locking devices described in this Chapter do not adequately secure the building, due to special conditions, he/she may require the installation and maintenance of an intrusion device (burglar alarm system). (C) Landscaping.
(1) Shrubs and ground cover shall not directly cover windows and doorways. (2) River rock used near parking lots or buildings shall be permanently affixed.
(3) Open space and buildings shall be arranged to afford visibility and opportunity for surveillance by on-site users and passers-by. (4) Barriers, both real and symbolic, shall be designed to afford opportunities for surveillance through the barrier.
(5) For residential development, backyard gates shall be the full height of the wall or fence adjacent and capable of being locked.
(6) For residential development, walls or fences, if installed, shall be a minimum of 6 feet in height when adjacent to any of the following:
Reverse frontage
Retention/detention areas
Parks
Commercial areas
Industrial areas
Bike paths
1834
(D) Lighting. Lighting of buildings or complexes shall at a minimum be illuminated as follows:
(1) A site plan shall be provided showing buildings, parking areas, walkways, detailed landscaping and a point-by-point photometric calculation of the required light levels.
(2) All exterior entrances shall be illuminated with a uniformly maintained minimum level of one foot candle of light between ground level and 6 vertical feet within a minimum radius of 15 feet from the center of the entrance between sunset and sunrise.
(3) Postal Service “gang boxes” (group postal boxes) shall be illuminated with a uniformly maintained minimum level of one foot candle of light. (4) Lighting of all exterior areas shall be designed to maximize surveillance and reduce conflicts with building design, mature landscaping, and to minimize glare.
(5) Open stairways shall be illuminated with a minimum maintained fivetenths (0.5) foot-candle of light in all landings and stair treads between sunset and sunrise. Enclosed stairways and enclosed common corridors shall be illuminated at all times with a minimum maintained one-foot candle of light on all landings and stair treads.
(6) Private streets, alleys, and emergency access roads shall be illuminated using the same standards as established for public thoroughfares. (7) Aisles, passageways, pedestrian walkways and recessed areas related to and within a building, a building complex, or providing access to a building or building complex from a parking lot or right of way shall be illuminated with a minimum uniformly maintained minimum level of one foot candle of light between ground level and six vertical feet between sunset and sunrise or other methods approved by the Building Official.
(8) Open parking lot and/or carport and refuse areas shall be provided with and maintained to a minimum of one foot-candle of light on the parking surface.
The Building Official may approve a lower light level, if it can be demonstrated that the lower level provides for sufficient security lighting. (9) Covered parking lots or covered portions of parking lots shall be illuminated with a uniformly maintained minimum level of one-foot candle of light between ground level and 6 vertical feet between sunset and sunrise. Lighting shall be designed so that architectural or structural features do not obstruct the minimum light coverage.
1835
(10) Parking structures or enclosed or partially enclosed parking lots shall be illuminated with a uniformly maintained minimum level of two-foot candles of light between ground level and 6 vertical feet between sunrise and sunset (daylight hours).
(11) Lighting fixtures shall be so arranged as to illuminate light uniformly over the parking surface and be tamper resistant.
(12) Public rest rooms, rooms identified for the general public and children’s recreation areas shall be provided with emergency lighting meeting section 1006 of this Code.
All light sources required by this section shall be: (a) controlled by a photocell device or a time clock that will turn the lights on at dusk and off at dawn and (b) protected by weather and vandal resistant covers.
(E) Garage Type (Vehicle) Doors. Garage-type doors, which are either rolling overhead, solid overhead, swinging, sliding, or accordion style doors shall conform to the following standards:
(1) Wood doors shall have panels a minimum of five-sixteenths (5/16) inch in thickness with the locking hardware being attached to the support framing. (2) Aluminum doors shall be a minimum thickness of .0215 inches and riveted together a minimum of 18 inches on center along the outside seams.
There shall be a full width horizontal beam attached to the main door structure which shall meet the pilot, or pedestrian access, door framing within 3 inches of the strike area of the pilot or pedestrian access door. (3) Fiberglass doors shall have panels a minimum density of 6 ounces per square foot from the bottom of the door to a height of 7 feet. Panels above 7 feet and panels in residential structures shall have a density not less than 5 ounces per square foot.
(4) Doors utilizing a cylinder lock shall have a lock receiving point at each outer edge of the door; or, if the door does not exceed 19 feet, a single bolt may be used if placed in the center of the door with the locking point located either at the floor or door frame header.
(5) Doors with slide bolt assemblies shall have frames a minimum of .120 inches of thickness, with a minimum bolt diameter of one half (1/2) inch and protrude at least one and one half (1 ½) inches into the receiving guide. A bolt diameter of three-eighths (3/8) inch may be used in a residential building. The slide bolt shall be attached to the door with non-removable bolts from the outside.
Rivets shall not be used to attach slide bolt assemblies. 1836
(6) Padlocks used with exterior mounted slide bolts shall have a hardened steel shackle locking at both heel and toe and a minimum five pin tumbler operation with non-removable key when in an unlocked position. Padlocks used with interior mounted slide bolts shall have a hardened steel shackle with a minimum 4-pin tumbler operation.
(F) Emergency Access
(1) Private roads and parking areas or structures controlled by unmanned mechanical parking type gates shall provide for emergency access as follows:
Radio frequency access or by providing the gate access code for distribution to emergency responders. When an access code is to be utilized, an illuminated control box is to be mounted on a control pedestal consisting of a metal post/pipe, which shall be installed at a height of 42 inches and a minimum of 15 feet (4.6m) from the entry/exit gate. It shall be located on the driver’s side of the road or driveway and accessible in such a manner as to not require a person to exit their vehicle to reach it, nor to drive on the wrong side of the road or driveway, nor to require any back-up movements in order to enter/exit the gate.
(2) Non-residential multi-tenant buildings utilizing electronic access control systems on the main entry doors, and enclosed retail shopping centers shall be provided with a means to allow for police emergency access. (3) Pedestrian gates/doors using an electromagnetic type lock shall install a key switch within a telephone/intercom console or in a control housing, or other method approved by the Building Official that will provide for police emergency access. Options include radio frequency access or providing the gate access code for distribution to emergency responders.
(4) All lockable pedestrian gates to residential recreation areas serving 6 or more dwelling units, and gates or doors to common walkways or hallways of residential complexes where there are 4 or more dwelling units within the complex, shall provide for police emergency access utilizing an approved key switch device or approved Knox box. The Knox box shall be installed adjacent to each gate/door, securely attaching it to a fence or wall or location approved by the Building Official.
(5) Pedestrian gate doors utilizing mechanical locks shall install a Knox box adjacent to each gate/door, securely attaching it to a fence or wall (G) Keying requirements
Upon occupancy by the owner or proprietor, each single unit in a tract or commercial development, constructed under the same site development review, 1837
shall have locks using combinations that are interchange free from locks used in all other separate dwellings, proprietorships, or similar distinct occupancies. (H) Laundry rooms or areas: Common area laundry rooms in multi-family complexes shall be designed and protected as follows:
(1) Entry doors shall have:
(a) A minimum six hundred (600) square inch clear vision panel in the upper half of the door, consisting of ¼” tempered glass; (b) Automatic, hydraulic door closures;
(c) Self-locking door locks equipped with a deadlocking latch allowing exiting by a single motion and openable from the inside without the use of a key or any special knowledge or effort;
(d) Non-removable hinge pins for out-swinging doors to preclude removal of the door from the exterior by removing the hinge pins; and (e) A latch protector consisting of minimum 0.125-inch-thick steel attached to the door’s exterior by non-removable bolts from the exterior. It shall be two (2) inches wide and extend a minimum of five inches above and below the strike opening and extend a minimum of one (1) inch beyond the edge of the door. It shall have a metal anti-spread pin a minimum of one-half (1/2) inch in length.
(2) The laundry room shall be illuminated at all times with a minimum maintained one-foot candle of light at floor level, using a non-interruptible power source. There shall be no light switches inside the room that control light fixtures used to meet this lighting requirement.
(3) Any portion of an openable window which is within eight (8) feet vertically or six (6) feet horizontally from any accessible surface or any adjoining roof, balcony, landing, stair tread, platform, or similar surface, or any climbable pole or tree, or any surface providing a foothold, shall be secured as required by section 1018 of the Uniform Building Security Code.
(4) The interior of laundry rooms shall be visible from the exterior along common walking or driving surfaces. Perimeter windows and interior mirrors may be utilized to meet this requirement. Laundry rooms are to be located in high activity areas with natural surveillance opportunities and not in remote or isolated locations.
(I) Elevators
Elevators shall be designed as follows:
1838
Elevator cabs, the interiors of which are not completely visible when the door is open from a point centered on the 36 inches away from the door shall have shatter resistant mirrors or other equally reflective material so placed as to make visible the entire elevator cab from this point. The elevator cab shall be illuminated at all times with a minimum maintained 2-foot candles of light at floor level.
(J) Stairways
Except for private stairways, Stairways shall be designed as follows:
(1) Interior doors shall have glazing panels a minimum of 5 inches wide and 20 inches in height and meet requirements of the California Building Code. (2) Areas beneath stairways at or below ground level shall be fully enclosed or access to them restricted.
(3) Enclosed stairways shall have shatter resistant mirrors or other equally reflective material at each level and landing and be designed or placed in such manner as to provide visibility around corners.
(K) Parking structures.
(1) Parking structures shall be designed to restrict unauthorized access. (2) Outside stairwells shall be open and not obstructed from view (3) Security telephones with monitoring capability shall be located on every level adjacent to pedestrian ingress/egress points. If pedestrian ingress/egress points are more than 200 feet but less than 300 feet apart, additional security telephones shall be located at the midpoint between pedestrian ingress/egress points. If pedestrian ingress/egress points are more than 300 feet apart, security telephones will be located at 100-foot intervals. Security telephones shall be visible from all vehicular and pedestrian ingress/egress points and identified with appropriate signage.
(4) Blind corners shall be provided with shatterproof convex mirrors to improve visibility for both operators of vehicles and pedestrians. (5) Doors shall be labeled with signage meeting the requirements of section 501.2
(6) Parking structures shall have the ceiling area of each floor or tier painted and maintained white or other reflective color approved by the Building Official. (L) Other requirements
1839
(1) Storage Areas. Exterior storage area attached to a dwelling, apartment or condominium and enclosed by a door shall comply with this section or have a minimum 3/8” diameter hardened padlock hasp.
(2) Side Gates. Side gates shall be the full height of the adjacent fence or wall and be capable of being locked. Side gates shall be secured with a slide bolt mounted on the inside of the gate. The slide bolt shall have a bolt diameter of three-eighths (3/8) inch and protrude at least one and one-half (1 ½) inches into the receiving guide. The slide bolt shall be attached to the gate with nonremovable bolts. Rivets shall not be used to attach slide bolt assemblies. The slide bolt shall be mounted at a height that is not accessible by reaching over the gate.
7.32.290 Section G101.4, Chapter Appendix G, Violations-Amended.
Section G101.4 is amended to read:
G101.4 Violations. Any violation of a provision of this appendix, or failure to comply with a permit or variance issued pursuant to this appendix or any requirement of this appendix, shall be enforced pursuant to Chapter
7.28 Dublin Municipal Code.
7.32.300 Section G101.5, Chapter Appendix G, Designation of floodplain administrator-Amended.
Section G101.5 is amended to read:
G101.5 Designation of floodplain administrator. The Building Official is designated as the floodplain administrator and is authorized and directed to enforce the provisions of this appendix. The floodplain administrator is authorized to delegate performance of certain duties to other employees of the jurisdiction. Such designation shall not alter any duties and powers of the Building Official.
5195888.1
1840
Attachment 8
Exhibit E to the Ordinance
Chapter 7.34
RESIDENTIAL CODE
Sections:
7.34.010 Title.
7.34.020 Purpose.
7.34.030 Adoption of Residential Codes.
7.34.040 Scope.
7.34.050 Additions, alterations and repairs-Generally.
7.34.060 Additions, alterations and repairs-Code compliance.
7.34.070 Alterations and repairs.
7.34.080 Additions.
7.34.090 Repair of roof covering.
7.34.100 Chapter R1, Division II, Administration- Deleted.
7.34.110 Section 202, Chapter 2, Definitions of Substantial Damage and Substantial Improvement – Added.
7.34.120 Table R301.2(1), Chapter R3 – Amended.
7.34.130 Section R301.2.4 Floodplain Construction – Amended.
7.34.140 Section R313.1 Exception, Chapter R3 Automatic Fire Sprinkler Systems – Amended.
7.34.150 Section R313.2 Exception, Chapter R3 Automatic Fire Sprinkler Systems – Amended.
7.34.160 Section R319.2, Chapter R3, Site Address - Added.
7.34.170 Section R322.1 Chapter R3, General – Amended.
7.34.180 Section R337.1.1 Chapter R3, Scope – Amended.
7.34.190 Section R337.2 Chapter R3, Definitions – Amended.
7.34.200 Section R350, Chapter R3, Building Security – Added.
7.34.210 Section R403.1.3, Chapter R4, Footing and stem wall reinforcing in Seismic Design Categories D0, D1, D2 –
Amended.
7.34.220 Table R602.10.3(3), Chapter R6, Bracing Requirements – Amended.
7.34.230 Section R602.10.4.4, Chapter R6, Limits on methods GB and PCP – Added.
7.34.240 Section R902, Chapter 9, Fire Classification-Amended.
7.34.250 Section R1001.1.2 Chapter 10, Prohibited Installations—Added.
7.34.260 Chapters 11 through 43 are Deleted.
1841
7.34.010 Title.
The residential codes adopted by section 7.34.030 and the provisions of this Chapter shall constitute the Dublin Residential Code and may be referred to as such.
7.34.020 Purpose.
The promotion and preservation of the public health, safety and general welfare of the people of the City and the property situated therein have made necessary the adoption of the residential codes referred to in Section 7.34.030 in order to adequately safeguard life, health, property, and general welfare. The purpose of this Code is not to create or otherwise establish or designate any particular class or groups of persons who will or should be especially protected or benefited by the terms of this Code.
7.34.030 Adoption of Residential Codes.
A. The 2022 California Residential Code, Part 2.5, Title 24 of the California Code of Regulations, a portion of the California Building Standards Code, as defined in the California Health and Safety Code Section 18901 et. seq. (hereinafter referred to as the "State Code"), and any rules and regulations promulgated pursuant thereto including the International Residential Code, 2021 Edition, including Appendix Chapters AH, AQ, AX, and AZ as published by the International Code Council, and as referenced in and adopted pursuant to California Health and Safety Code Sections 17922 and 18935, (hereinafter referred to as the “IRC”) are hereby adopted and incorporated by reference herein.
Copies of the adopted codes have been and are now filed in the Office of the Building Official, 100 Civic Plaza, Dublin, California, for use and examination by the public. Said codes are adopted by reference pursuant to Section 50022.4, et seq., of the Government Code of the State of California, and the codes are hereby adopted and incorporated as fully as if set out at length herein, and from the date on which this Ordinance shall take effect, the provisions thereof shall be controlling within the limits of the City of Dublin.
B. Notwithstanding the provisions of Section 7.34.030.A, the State Code and the IRC are amended as set forth in Sections 7.34.100 through 7.34.260.
7.34.040 Scope.
A. The provisions of this Code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal, and demolition of every detached one- and twofamily dwellings, townhouse not more than three stories above grade plane in height with a separate means of egress and accessory structures not more than three stories above grade plan in height throughout the City. 1842
Exception: The following shall be permitted to be constructed in accordance with this code where provided with automatic sprinklers systems complying with Section R313:
1: Live/work units located in townhouses and complying with requirements of Section 508.5 of the California Building Code.
2: Owner-occupied lodging houses with five or fewer guestrooms.
B. The permissive provision of this Code shall not be presumed to waive any limitations imposed by any other law, ordinance, rule, or regulation. If two or more pertinent limitations are not identical, those limitations shall prevail which provide greater safety to life, health, property, or public welfare.
C. Buildings shall be made accessible to persons with disabilities as required by Title 24 California Code of Regulation. Whenever there is a conflict between the provisions of this Code and Title 24, California Code of Regulations with respect to the accessibility of buildings, structures or spaces to persons with disabilities, the provisions of Title 24 shall prevail.
D. See the California Energy Code for energy conservation requirements, California Mechanical Code for mechanical requirements, California Plumbing Code for plumbing requirements and the California Electrical Code for electrical requirements. In addition, see the California Building Code for interior environment requirements.
7.34.050 Additions, alterations and repairs-Generally.
Buildings or structures to which additions, alterations, or repairs are made shall comply with all the requirements of this Code for new buildings or structures except as specifically provided for in this section and Sections 7.34.060 through
7.34.090.
7.34.060 Additions, alterations and repairs-Code compliance.
Additions, alterations or repairs may be made to any building or structure without requiring the existing building or structure to comply with all the requirements of this Code, provided the addition, alteration or repair conforms to that required for a new building or structure. Additions or alterations shall not be made to an existing building or structure which will cause the existing building or structure to be in violation of any of the provisions of this Code nor shall such additions or alterations cause the existing building or structure to become unsafe.
An unsafe condition shall be deemed to have been created if an addition or alteration will cause the existing building or structure to become structurally unsafe or overloaded; will not provide adequate egress in compliance with the provisions of this Code or will obstruct existing exits; will create a fire hazard; will reduce required fire resistance or will otherwise create conditions dangerous to human life. Any building so altered, which involves a change in use or 1843
occupancy, shall not exceed the height, number of stories and area permitted for new buildings. Any building plus new additions shall not exceed the height, number of stories and area specified for new buildings. Additions or alterations shall not be made to an existing building or structure when such existing building or structure is not in full compliance with the provision of this Code.
7.34.070 Alterations and repairs.
A. The provisions of Section 7.34.060 shall not prohibit the alteration or repair of any legally established existing one- and two-family dwelling or townhouse not more than three stories above grade plane in height with a separate means of egress or structure accessory thereto which retains, replaces or extends the use of the original materials or continued use of original methods of construction provided such alteration or repair does not create or continue a dangerous building as defined in Section 7.28.020, a substandard building as defined in Section 7.28.090. However, such alteration or repair shall not reduce any required fire resistance below that specified by this Code, reduce the resistance to lateral forces below that specified by this Code, or increase the stress or deflection of any member so as to exceed that specified by this Code.
B. The provisions of Section 7.34.060 pertaining to additions shall not require any legally existing one- and two-family dwelling or townhouse not more than three stories above grade plane in height with a separate means of egress, or structure accessory thereto to be made to conform to the provisions of this Code solely because of the construction of the addition. However, this section shall not be constructed to permit the addition to increase the stress or deflection of any existing member so as to exceed that specified by the Building Code. Whenever an addition increases the number of occupants which must exit through the existing building, all of the exit facilities serving the increased number of occupants shall comply with the provisions of this Code.
C. Whenever a new dwelling unit is created either by new construction, or by an alteration to an existing building, separate gas and electrical meters shall be provided, except where Government Code Section 65852.22 provides an exception to such a requirement.
7.34.080 Additions.
Notwithstanding the provisions of Section 7.28.240, whenever alterations, repairs, or additions requiring a permit or one (1) or more sleeping rooms are added or created in existing Group R, Division 3 Occupancies, the entire building shall be provided with smoke alarms and carbon monoxide alarms located as required for new Group R, Division 3 Occupancies.
Furthermore, spark arrestors shall be installed on all chimneys connected to solid burning fuel-burning appliances.
1844
7.34.090 Repair of roof covering.
Roof coverings may be repaired or replaced with materials as set forth in Section 7.32.180 of the Dublin Municipal Code.
7.34.100 Chapter R1, Division II Administration-Deleted.
Chapter R1 Division II is deleted.
7.34.110 Section 202, Chapter 2, Definitions of Substantial Damage and Substantial Improvement.
The definitions of “Substantial Damage” and “Substantial Improvement” in Section 202 of the State Code are amended to read as follows:
Substantial Damage. Damage of any origin sustained by a structure whereby the cost of restoring the structure to its before-damaged condition would equal or exceed 50 percent of the market value of the structure before the damage occurred. The term also includes flood-related damage sustained by a structure on two separate occasions during a 10-year period for which the cost of repairs at the time of each such flood event, on average, equals or exceeds 25 percent of the market value of the structure before the damage occurred.
Substantial Improvement. Any one or more or any combination of repair, reconstruction, rehabilitation, alterations, addition or other improvement of a building or structure taking place during a 10-year period, the cumulative cost of which equals or exceeds 50 percent of the market value of the structure before the improvement or repair is started. For each building or structure, the 10-year period begins on the date of the first permit issued for improvement or repair of that building or structure subsequent to January 1, 2023. If the structure has sustained substantial damage, any repairs are considered substantial improvement regardless of the actual repair work performed. The term does not, however, included either:
1. Any project for improvement of a building required to correct existing health, sanitary or safety code violations identified by the building official and that are the minimum necessary to assure safe living conditions.
Any alteration of a historic structure provided that the alteration will not preclude the structure’s continued designation as a historic structure. 1845
7.34.120 Table R301.2, Chapter R3 – Amended.
Table R301.2 is amended to read:
GROUND
SNOW
LOAD o
WIND DESIGN
SEISMIC DESIGN
CATEGORY Speed f
(mph)
Topographic
Effects k
Special wind
region I
Windborne
debris zone
N/A 92 NO NO NO D2
SUBJECT TO DAMAGE FROM
ICE BARRIER
UNDERLAYMENT
REQUIRED h
FLOOD
HAZARDS g
AIR
FREEZING
INDEX i
MEAN
ANNUAL
TEMP j Weathering a
Frost line
depth b Termite c
Negligible 12" Very Heavy NO 9/14/1987
See FIRM 2% 58.7
MANUAL J DESIGN CRITERIA n
Elevation
Altitude
correction
factor e
Coincident
wet bulb
Indoor winter
design relative
humidity
Indoor winter
design drybulb
temperature
Outdoor
Winter
design drybulb
temperature
Heating
temperature
difference
200 1 67 75% 68% 32 36
Latitude Daily
range
Indoor
summer
design
relative
humidity
Indoor summer
design dry-bulb
temperature
Outdoor
summer
design drybulb
temperature
Cooling temperature
difference
38 35 75% 75% 90 15
7.34.130 Section R301.2.4 Floodplain Construction – Amended.
Section R301.2.4 is amended to read:
Buildings and structures constructed in whole or in part in flood hazard areas (including A or V Zones) as established in Table R301.2(1), and substantial improvement and repair of substantial damage of buildings and structures in floor hazard areas, shall be designed and constructed in accordance with ASCE24. Buildings and structures that are located in more than one flood hazard area shall comply with the provisions associated with the most restrictive flood hazard area.
7.34.140 Section R313.1 Exception, Chapter R3 Townhouse Automatic Fire Sprinkler Systems – Amended.
Section R313.1 Exception is amended to read:
1846
Exception: An automatic sprinkler systems shall not be required where additions or alteration are made to existing townhouses that do not have an automatic sprinkler system installed, provided that the total square footage of the existing building plus the addition does not exceed 3600 square feet (334m²).
Additions or alteration that remove 50 percent or more of the existing exterior walls of a dwelling shall be considered a new dwelling for the purposes of Section R313.1.
7.34.150 Section R313.2 Exception 1, Chapter R3 One and Two-family Dwellings Automatic Fire Sprinkler Systems – Amended.
Section R313.2 Exception 1 is amended to read:
Exception: 1. An automatic residential fire sprinkler system shall not be required for additions or alteration to existing building that are not already provided with an automatic residential sprinkler system, provided that the total square footage of the existing building plus the addition does not exceed 3600 square feet (334m²). Additions or alteration that remove 50 percent or more of the existing exterior walls of a dwelling shall be considered a new dwelling for the purposes of Section R313.2.
7.34.160 Section R319.2, Chapter R3, Site Address - Added.
Section R319.2, is added to read:
R319.2 Address Location. Address shall be installed in the following locations:
1 Walkways serving six (6) or more individual units where the front entrance is not parallel to the street and driveways servicing six (6) or more individual dwelling units shall have minimum of four (4) inch high identification numbers, noting the range of unit numbers placed at the entrance to each driveway at a height between thirty-six (36) and forty-two (42) inches above grade. The address numbers shall be illuminated during the hours of darkness. The light source shall be provided with an uninterruptible AC power source or controlled only by a photoelectric device or photovoltaic powered.
2. No other number may be affixed to a structure that might be mistaken for, or confused with, the number assigned to the structure.
3. If the building is adjacent to an alley, the number shall also be placed on or adjacent to the rear gate accessing the alley.
4. For multifamily buildings with recessed entryway over 2 feet, an additional lighted address shall be placed at the entryway to the recessed area. If the recessed area provides access to more than one dwelling unit, the range of units shall be displayed.
1847
5. Each principal building of a multifamily complex shall display the number or letter assigned to that building on each corner of the building at a height that will prevent the number from being obscured by landscaping.
6. Any building with vehicular access to the rear through a public or private alley shall display, in a clearly visible location, a highly reflective or illuminated address number a minimum of four (4) inches in height.
7. Address numbers shall not be obstructed by architectural structures such as trellises, arbors, balconies, light fixtures and or landscaping.
7.34.170 Section R322.1 Chapter R3, General – Amended.
Section R322.1 is amended to read:
R322.1 General. Buildings and structures constructed in whole or in part in flood hazard areas, including A or V Zones and Coastal A Zones, as established in Table R301.2(1), and substantial improvement and repair of substantial damage of buildings and structures in flood hazard areas, shall be designed and constructed in accordance with ASCE24 Buildings and structures that are located in more than one flood hazard area shall comply with the provisions associated with the most restrictive flood hazard area.
7.34.180 Section R337.1.1 Chapter R3, Scope – Amended.
Section R337.1.1 is amended to read:
R337.1.1 Scope. Section R337 and all subsections apply to building materials, systems and or assemblies used in the exterior design and construction of new buildings located within a Wildland-Urban Interface (WUI) Fire Area as defined in Section R337.2 or adjacent to open space or undeveloped land.
7.34.190 Section R337.2 Chapter R3, Definitions – Amended.
Section 337.2 is amended to add the following definitions:
Adjacent to Open Space. Shall mean commercial parcels and residential lots which have a point of contact with open space.
Adjacent to Undeveloped Land. Shall mean commercial parcels and residential lots which have a point of contact with Undeveloped Land.
Open Space. For the purpose of this Chapter, Open Space shall mean those lands set aside to remain permanently undeveloped.
Undeveloped Land. For the purpose of this Chapter, Undeveloped Land shall mean land which is available for development, but no Tentative Map, Master 1848
Tentative Map or Development Agreement has been approved, and any land designated for government use.
7.34.200 Section R350, Chapter R3, Building Security – Added.
Section R350 is added to read:
R350.1 Building Security. Residential building security shall be in accordance with the Uniform Building Security Code in addition to the following:
R350.2 Exterior doors: Each exterior door shall be secured as follows:
1. Exterior doors (excluding glass patio doors) and doors leading from garage areas into dwellings shall be equipped with a dead bolt lock with one-inch (1") throw.
2. Pairs of doors shall have flush bolts with a minimum throw of five-eighths inch (5/8") at the head and foot (floor and ceiling) of the inactive leaf.
3. Doorstop on a wooden jamb for an in-swing door shall be of one-piece construction with the jamb joined by a rabbet.
4. Locks shall be provided on all sliding patio doors.
5. Sliding patio glass doors opening onto patios or balconies which are less than one story above grade or are otherwise accessible from the outside shall have the moveable section of the door sliding on the inside of the fixed portion of the door or possess an approved secondary lock mounted on interior of moveable section.
6. The lock bolt on all glass patio doors shall engage the strike sufficiently to prevent its being disengaged by any possible movement of the door within the space or clearance provided for installation and operation. The strike area shall be of material adequate to maintain effectiveness of bolt strength.
R350.3 Landscaping.
1. Shrubs and ground cover shall not directly cover windows and doorways.
2. River rock used near parking lots or buildings shall be permanently affixed.
3. Backyard gates shall be the full height of the wall or fence adjacent and capable of being locked.
4. Open space and buildings shall be arranged to afford visibility and opportunity for surveillance by on-site users and passers-by. 1849
5. Barriers, both real and symbolic, shall be designed to afford opportunities for surveillance through the barrier.
6. For residential development, walls or fences, if installed, shall be a minimum of 6 feet in height when adjacent to any of the following:
Reverse frontage,
Retention/detention areas,
Parks, Commercial areas,
Industrial areas, or
Bike paths.
R350.4 Garage Type (Vehicle) Doors. Garage-type doors, which are either rolling overhead, solid overhead, swinging, sliding, or accordion style doors shall conform to the following standards;
1. Wood doors shall have panels a minimum of five-sixteenths (5/16) inch in thickness with the locking hardware being attached to the support framing.
2.Aluminum doors shall be a minimum thickness of .0215 inches and riveted together a minimum of 18 inches on center along the outside seams. There shall be a full width horizontal beam attached to the main door structure which shall meet the pilot, or pedestrian access, door framing within 3 inches of the strike area of the pilot or pedestrian access door.
3. Fiberglass doors shall have panels a minimum density of 6 ounces per square foot from the bottom of the door to a height of 7 feet. Panels above 7 feet and panels in residential structures shall have a density not less than 5 ounces per square foot.
4. Doors utilizing a cylinder lock shall have a lock receiving point at each outer edge of the door; or, if the door does not exceed 19 feet, a single bolt may be used if placed in the center of the door with the locking point located either at the floor or door frame header.
5. Doors with slide bolt assemblies shall have frames a minimum of .120 inches of thickness, with a minimum bolt diameter of one half (1/2) inch and protrude at least one and one half (1 ½) inches into the receiving guide. A bolt diameter of three-eighths (3/8) inch may be used in a residential building. The slide bolt shall be attached to the door with non-removable bolts from the outside.
Rivets shall not be used to attach slide bolt assemblies.
R350.5 Emergency Access. Private roads and parking areas or structures controlled by unmanned mechanical parking type gates shall provide for police emergency access as follows:
1850
1. Radio frequency access or by providing the gate access code for distribution to emergency responders. When an access code is to be utilized, an illuminated control box shall be mounted on a control pedestal consisting of a metal post/pipe which shall be installed at a height of 42 inches and a minimum of 15 feet (4.6m) from the entry/exit gate. It shall be located on the driver’s side of the road or driveway and accessible in such a manner as to not require a person to exit their vehicle to reach it, nor to drive on the wrong side of the road or driveway, nor to require any back-up movements in order to enter/exit the gate.
2. All lockable pedestrian gates to residential recreation areas serving 6 or more dwelling units, and gates or doors to common walkways or hallways of residential complexes where there are 4 or more dwelling units within the complex, shall provide for police emergency access utilizing an approved key switch device or approved Knox box.
3. Pedestrian gates/doors using an electromagnetic type lock shall install a key switch within a telephone/intercom console or in a control housing, or other method approved by the Building Official that will provide for police emergency access. See 350.5.1 for options.
4. Pedestrian gate/doors (including pedestrian gates/doors in pool enclosures and recreational facilities) utilizing mechanical locks shall install a Knox box adjacent to each gate/door, securely attaching it to a fence or wall.
R350.6 Keying requirements. Upon occupancy by the owner or proprietor, each single unit in a tract constructed under the same site development review, shall have locks using combinations that are interchange free from locks used in all other separate dwellings, proprietorships, or similar distinct occupancies.
R350.7 Other requirements
1. Storage Areas. Any exterior storage area attached to a dwelling enclosed by a door shall comply with this section or have a minimum 3/8” diameter hardened padlock hasp.
2. Side Gates. Side gates shall be the full height of the adjacent fence or wall and be capable of being locked. Side gates shall be secured with a slide bolt mounted on the inside of the gate. The slide bolt shall have a bolt diameter of three-eighths (3/8) inch and protrude at least one and one-half (1 ½) inches into the receiving guide. The slide bolt shall be attached to the gate with nonremovable bolts. The slide bolt shall be mounted at a height that is not accessible by reaching over the gate.
7.34.210 Section R403.1.3, Chapter R4, Footing and stem wall reinforcing in Seismic Design Categories D0, D1, D2. – Amended. 1851
Section R403.1.3 is amended to read:
R403.1.3 Footing and stem wall reinforcing in Seismic Design Categories D0, D1, D2. Concrete footings located in Seismic Design Categories D0, D1 and D2, as established in Table R301.2, shall have minimum reinforcement of at least two continuous longitudinal reinforcing bars, one top and one bottom and not smaller than No. 4 bars. Bottom reinforcement shall be located a minimum of 3 inches (76 mm) clear from the bottom of the footing.
7.34.220 Table R602.10.3(3), Chapter R6, Bracing Requirements – Amended.
Table R602.10.3(3) is amended by adding a new footnote “i” to read:
i. Methods PBS, HPS, SFB and CS-SFB are not permit in Seismic Design Categories D0, D1, and D2 .
j. Methods GB, DWB and PCP are not permitted in Seismic Design Categories D0, D1, and D2 where S1 is greater than or equal to 0.75.
Add the “i, j” footnote notation in the title of Table R602.10.3(3) to read:
TABLE R602.10.3(3)i, j
7.34.230 Section R602.10.4.5, Chapter R6, Limits on methods GB and PCP – Added.
A new Section R602.10.4.5 is added to read:
R602.10.4.5 Limits on methods GB and PCP. In Seismic Design Categories D0, D1, and D2, Method GB is not permitted for use as intermittent braced wall panels, but gypsum board is permitted to be installed when required by this Section to be placed on the opposite side of the studs from other types of braced wall panel sheathing. In Seismic Design Categories D0, D1, and D2, the use of Method PCP is limited to one-story single-family dwellings and accessory structures.
7.34.240 Section R902, Chapter 9, Fire Classification-Amended.
Section R902.1 is amended to read:
R902.1 Roof covering materials. Roofs shall be covered with materials as set forth in Sections R904 and R905. A minimum Class A, B or C roofing shall be installed in areas as designated below or where the edge of the roof is less than 3 feet from a lot line. Class A, B and C roofing required by this section to be listed shall be tested in accordance with UL 790 or ASTM E 108.
1852
1. Map of Fire Safe Roof Areas. Figure 15-1* is a map of Fire Safe Roof
areas. Said map may be amended from time to time by including areas which are
annexed to the City within one of the two roofing areas. Said amendments may be
made by the Building Official after consultation, with the Chief of the Fire Department or their designee having jurisdiction.
2. Roofing Area 1. Any new roof and any alteration, repair or replacement for
buildings housing R & U-1 occupancies in Roofing Area 1 shall use roof covering
material that conforms to Class B or better or shall be made of concrete, ferrous or copper metal, clay, slate or similar non-combustible material.
3. Roofing Area 2. Any new roof for buildings using roof covering material
that conforms to Class C or better or shall be made of concrete, ferrous or copper metal, clay, slate or similar non-combustible material. * Editor's Note: Figure 15-1 is on file in the office of the City Clerk.
7.34.150 Section R1001.1.2 Chapter 10, Prohibited Installations—Added.
A new Section R1001.1.2 is added to read:
R1001.1.2 Prohibited Installations. It shall be unlawful to install a new wood burning fireplace or appliance that is not one of the following:
1) Pellet-fueled wood heater,
2) EPA certified wood heater,
3) Fireplace certified by EPA
7.34.260 Chapters 11 through 43 are Deleted.
Chapters 11 through 43 are deleted.
5195914.1
1853
Attachment 9
Exhibit F to the Ordinance
Chapter 7.36
ELECTRICAL CODE
Sections:
7.36.010 Title.
7.36.020 Purpose.
7.36.030 Adoption of Electrical Codes.
7.36.040 Scope.
7.36.050 Exceptions.
7.36.060 Additions, alterations and repairs.
7.36.070 Section 210.53, Office receptacle outlets-Added.
7.36.010 Title.
The buildings codes adopted by reference in Section 7.36.030 and the provisions of this Chapter shall constitute the Dublin Electrical Code and may be referred to as such.
7.36.020 Purpose.
A. The promotion and preservation of the public health, safety, and general welfare of the people of the City and the property situated therein have made necessary the adoption of the electrical codes referred to in Section 7.36.030 in order to adequately safeguard life, health, property, and general welfare.
B. The purpose of this code is not to create or otherwise establish or designate any particular class or groups of persons who will or should be especially protected or benefited by the terms of this code.
7.36.030 Adoption of Electrical Codes.
A. The 2022 California Electrical Code, Part 3, Title 24 of the California Code of Regulations, a portion of the California Building Standards Code, as defined in the California Health and Safety Code Section 18901 et. seq. (hereinafter referred to as the "State Code"), and any rules and regulations promulgated pursuant thereto including the National Electrical Code, 2020 Edition, as published by the National Fire Protection Association, and as referenced in and adopted pursuant to California Health and Safety Code Sections 17922 and 18935, (hereinafter referred to as the "NEC") are hereby adopted and incorporated by reference herein.
Copies of the adopted codes have been and are now filed in the Office of the Building Official, 100 Civic Plaza, Dublin, California, for use and examination by the public. Said codes are adopted by reference pursuant to Section 50022.4, et seq., of the Government Code of the State of California, and the codes are hereby adopted and incorporated as fully as if set out at length herein, and from the date on which this Ordinance shall take effect, the provisions thereof shall be controlling within the limits of the City of Dublin.
1854
B. Notwithstanding the provisions of Section 7.36.030.A, the State Code and the NEC are amended as set forth in Section 7.36.080.
7.36.040 Scope.
A. The provisions of this code shall apply to the installation, erection, construction, enlargement, addition to, alteration, repair, moving, removal demolition, conversion, use, and maintenance of any electrical wiring, appliances, devices, equipment, and apparatuses used for or in connection with the transmission or use of electrical energy for light, heat, power, radio, signaling communication or for other purpose in any building, structure, or premises within the City.
B. The permissive provisions of this code shall not be presumed to waive any limitations imposed by any other law, ordinance, rule, or regulation. If two (2) or more pertinent limitations are not identical, those limitations shall prevail which provide greater safety to life, health, property or public welfare.
C. Electrical appliances and equipment shall be made accessible to the physically handicapped. Whenever there is a conflict between the provisions of this code and Title 24 California Code of Regulation, the provisions of Title 24 shall prevail.
7.36.050 Exceptions.
The provisions of this code shall not apply to:
A. Work located in a public street;
B. Electrical installations within trailer coaches, campers, motor vehicles, railroad cars and aircraft; however, if any of the foregoing are permanently placed on the ground or have their wheels removed for other than temporary repairs, they shall comply with all the provisions of the electrical code; C. Electrical installations within houseboats or other watercrafts; however, if any of the foregoing are stored out of the water and used for any purpose whatsoever, they shall comply with all the provisions of the electrical code; D. Electrical installations owned or operated by a public utility for the use of such utility in the generation, transmission, distribution or metering of electrical energy;
E. Radio and television receiving equipment, amateur radio transmitting and receiving equipment, and community antenna television systems.
7.36.060 Additions, alterations and repairs.
A. All work done in connection with an addition to an existing electrical installation shall conform to the applicable provisions of this code. In addition, any portion of an existing electrical installation which would become overloaded or have its capacity exceeded as determined by the standards in this code for new installation as a result of the addition shall be made to conform to the applicable provisions of this code.
B. Alterations, repairs to, or replacement of equipment in any existing electrical installation shall conform to the applicable provisions of this code except that the Building Official may allow deviations from the provisions of this code, provided 1855
the deviations are necessary due to the circumstances of the existing conditions; the existing condition was permitted by a previous Code; and such deviation does not create or continue a hazard to life, health, and property.
7.36.070 Section 210.53, Office receptacle outlets-Added.
Section 210.53 is added to read:
210.53 Office Receptacle Outlets. In office buildings or offices exceeding ten (10) percent of the floor area of the major use, receptacle outlets shall be installed in all permanent walls or partitions of each office so that no point along the floor line any wall space is more than six (6) feet (1.83m) measured horizontally, from an outlet in that space including any wall space two (2) feet (610 mm) or more in width and the wall space occupied by sliding panels in exterior walls.
As used in the section a "wall space" shall be considered a wall unbroken along the floor line by doorways, fireplaces and similar openings.
Each wall space two (2) or more feet (610 mm) wide shall be treated individually and separately from other wall spaces within the room. A wall space shall be permitted to include two or more walls of a room (around corners) where unbroken at the floor line.
As used in this section “office space” means an enclosed office space with hard walls. Open office floor plans are not affected by this section.
Receptacle outlets shall, insofar as practicable be spaced equal distances apart. Receptacle outlets in floors shall not be counted as part of the required number of receptacle outlets unless located near the wall.
The receptacle outlets required by the section shall be in addition to any receptacle that is part of any lighting fixture or appliance, located within cabinets or cupboards, or located over five and one-half (5 ½) feet (1.68 m) above the floor.
5195936.1
1856
Attachment 10
Exhibit G to the Ordinance
Chapter 7.40
PLUMBING CODE
Sections:
7.40.010 Title.
7.40.020 Purpose.
7.40.030 Adoption of Plumbing Codes.
7.40.040 Scope.
7.40.050 Exceptions.
7.40.060 Additions, alterations and repairs.
7.40.070 Chapter 1, Division II, Administration–Deleted.
7.40.080 Section 609.3, Chapter 6, Water piping in slab floors–Amended.
7.40.010 Title.
The plumbing codes adopted by reference in Section 7.40.030 and the provisions of this Chapter shall constitute the Dublin Plumbing Code and may be referred to as such.
7.40.020 Purpose
A. The promotion and preservation of the public health, safety and general welfare of the people of the City and the property situated therein have made necessary the adoption of the plumbing codes referred to in Section 7.40.030 in order to adequately safeguard life, health, property, and general welfare.
B. The purpose of this code is not to create or otherwise establish or designate any particular class or groups of persons who will or should be especially protected or benefited by the terms of this code.
7.40.030 Adoption of Plumbing Codes.
A. The 2022 California Plumbing Code, Part 5, Title 24 of the California Code of Regulations, a portion of the California Building Standards Code, as defined in the California Health and Safety Code Section 18901 et. seq. (hereinafter referred to as the "State Code"), and any rules and regulations promulgated pursuant thereto including the Uniform Plumbing Code, 2021 Edition, including Appendix Chapters A, B, D, H, and I, as published by the International Association of Plumbing and Mechanical Officials, and as referenced in and adopted pursuant to California Health and Safety Code Sections 17922 and 18935, (hereinafter referred to as the "UPC") are hereby adopted and incorporated by reference herein.
Copies of the adopted codes have been and are now filed in the Office of the Building Official, 100 Civic Plaza, Dublin, California, for use and examination by the public. Said codes are adopted by reference pursuant to Section 50022.4, et seq., of the Government Code of the State of California, and the codes are hereby adopted and incorporated as fully as if set out at length herein, and from the date on which this Ordinance shall take effect, the provisions thereof shall be controlling within the limits of the City of Dublin. 1857
B. Notwithstanding the provisions of Section 7.40.030.A, the State Code and the UPC are amended as set forth in Sections 7.40.070 through 7.40.080 of this Chapter.
7.40.040 Scope.
A. The provisions of this code shall apply to the installation, erection, construction, enlargement, addition to, alteration, repair, movement, relocation, replacement removal, demolition, conversion, use, and maintenance of any plumbing installation, gas or drainage piping installation or any fixture or water heating or treating equipment, or maintenance of plumbing systems in any building, structure, or premises within the City.
B. The permissive provisions of this code shall not be presumed to waive any limitations imposed by any other law, ordinance, rule, or regulation. If two (2) or more pertinent limitations are not identical, those limitations shall prevail which provide greater safety to life, health, property, or public welfare.
C. Plumbing fixtures and equipment shall be made accessible to the physically handicapped. Whenever there is a conflict between the provisions of this code and Title 24, California Code of Regulations, the provisions of Title 24 shall prevail.
7.40.050 Exceptions.
The provisions of the plumbing code shall not apply to:
A. Work located in a public street:
B. Plumbing systems within trailer coaches, campers, motor vehicles, railroad cars and aircraft: however, if any of the foregoing are permanently placed on the ground or have their wheels removed for other than temporary repairs, they shall comply with all the provisions of the plumbing code:
C. Plumbing systems within houseboats or other watercraft; however, if any of the foregoing are stored out of water and used for any purpose whatsoever, they shall comply with all the provisions of the plumbing code;
D. Building sewers as defined in Chapter 2 of the California Plumbing Code located within the boundaries of a sanitary district and such district has regulations for building sewers and such regulations are in force;
E. Sewage treatment and collection facilities of a sanitary district; F. Water treatment, storage, transmission and distribution facilities of a water district or water company regulated by the Public Utilities Commission:
G. Gas storage, transmission and distribution facilities owned by a public utility:
H. Wells and water supply systems for irrigation and watering livestock provided such water is not used for human consumption.
7.40.060 Additions, alterations and repairs.
A. All work done in connection with an addition to an existing plumbing installation shall conform to the applicable provisions of this code. In an addition, any portion of an existing plumbing installation that would become overloaded or have its capacity exceeded as determined by the standards in this code for new installation as a result of the addition shall be made to conform to the applicable provision of this code.
B. Alterations, repairs to, or replacement of equipment in any existing plumbing installation shall conform to the applicable provisions of this code except that the Building Official may allow deviations from the provisions of this code, provided the 1858
deviations are necessary due to the circumstance of the existing conditions; the existing condition was permitted by a previous code; and such deviation does not create or continue a hazard to life, health and property.
7.40.070 Chapter 1 Division II Administration–Deleted.
Chapter 1 Division II is deleted.
7.40.080 Section 609.3, Chapter 6, Under Concrete Slab–Amended.
Section 609.3, first paragraph, is amended by replacing it to read:
Section 609.3 Water piping shall not be installed in or under a concrete floor slab within a building without prior approval of the Building Official. When approved, such piping shall be installed in accordance with the following requirements:
5196100.1
1859
Attachment 11
Exhibit H to the Ordinance
Chapter 7.44
MECHANICAL CODE
Sections:
7.44.010 Title.
7.44.020 Purpose.
7.44.030 Adoption of Mechanical Codes.
7.44.040 Scope.
7.44.050 Exceptions.
7.44.060 Additions, alterations and repairs.
7.44.070 Chapter 1, Division II, Administration–Deleted.
7.44.010 Title
The mechanical codes adopted by reference in Section 7.44.030 and the provisions of this Chapter shall constitute the Dublin Mechanical Code and may be referred to as such.
7.44.020 Purpose.
A. The promotion and preservation of the public health, safety and general welfare of the people of the City and the property situated therein have made necessary the adoption of the mechanical codes referred to in Section 7.44.030 in order to adequately safeguard life, health, property, and general welfare.
B. The purpose of this code is not to create or otherwise establish or designate any particular class or group of persons who will or should be especially protected or benefited by the terms of this code.
7.44.030 Adoption of Mechanical Codes.
A. The 2022 California Mechanical Code, Part 4, Title 24 of the California Code of Regulations, a portion of the California Building Standards Code, as defined in the California Health and Safety Code Section 18901 et. seq. (hereinafter referred to as the "State Code"), and any rules and regulations promulgated pursuant thereto including the Uniform Mechanical Code, 2021 Edition, including Appendix Chapters B, and C , as published by the International Association of Plumbing and Mechanical Officials, and as referenced in and adopted pursuant to California Health and Safety Code Sections 17922 and 18935, (hereinafter referred to as the "UMC") are hereby adopted and incorporated by reference herein.
Copies of the adopted codes have been and are now filed in the Office of the Building Official, 100 Civic Plaza, Dublin, California, for use and examination by the public. Said codes are adopted by reference pursuant to Section 50022.4, et seq., of the Government Code of the State of California, and the codes are hereby adopted and incorporated as fully as if set out at length herein, and from the date on which this Ordinance shall take effect, the provisions thereof shall be controlling within the limits of the City of Dublin.
1860
B. Notwithstanding the provisions of Section 7.44.030.A, the State Code and the UMC are amended as set forth in Section 7.44.070.
7.44.040 Scope.
A The provisions of this code shall apply to the installation, erection, construction, enlargement, addition to, alteration, repair, movement, relocation, removal, demolition, replacement, conversion, use, and maintenance of any heating, ventilating, comfort cooling, refrigeration systems, incinerators or other heat producing appliances, mechanical systems in any building, structure, or premises within the City.
B. The permissive provisions of this code shall not be presumed to waive any limitations imposed by any other law, ordinance, rule or regulation. If two (2) or more pertinent limitations are not identical, those limitations shall prevail which provide greater safety to life, health, property or public welfare.
C. Mechanical appliances and equipment shall be made accessible to the physically handicapped as required by Title 24 California Code of Regulations.
Whenever there is a conflict between the provisions of this code and Title 24, California Code of Regulations, the provisions of Title 24 shall prevail.
7.44.050 Exceptions
The provisions of the mechanical code shall not apply to:
A. Work located in a public street;
B. Heating, ventilation, comfort cooling, refrigeration systems, incinerators or other heating or cooling appliances within trailer coaches, campers, mobile homes, motor vehicles and airplanes: however, if any of the foregoing are permanently placed on the ground or have their wheels removed for other than temporary repairs, they shall comply with all the provisions of this code; C. Heating, ventilating, comport cooling, refrigeration systems, incinerators or other heating or cooling appliances within houseboats or other watercraft:
however, if any of the foregoing are stored out of water and used for any purpose whatsoever, they shall comply with all the provisions of this code.
7.44.060 Additions, alterations and repairs.
A. All work done in connection with an addition to an existing mechanical installation shall conform to the applicable provisions of this code. In addition, any portion of an existing mechanical installation which would become overloaded or have its capacity exceeded as determined by the standards in this code for new installations as a result of the addition shall be made to conform to the applicable provisions of this code.
B. Alterations, repairs to, or replacement of equipment in any existing mechanical installation shall conform to the applicable provisions of this code except that the Building Official may allow deviations from the provisions of this code, provided the deviations are necessary due to the circumstance of the existing condition; the existing condition was permitted by a previous code; and such deviation does not create or continue a hazard to life, health and property. 1861
7.44.070 Chapter 1, Division II, Administration–Deleted.
Chapter 1, Division II, is deleted.
1862
Attachment 12
Exhibit I to the Ordinance
Chapter 7.45
SWIMMING POOL AND SPA CODE
7.45.010 Title
7.45.020 Purpose.
7.45.030 Adoption.
7.45.040 Scope.
7.45.050 Exceptions
7.45.060 Amendments to the International Swimming Pool and Spa Code.
7.45.070 Sections 101 through 109, and Sections 111 through 114, Chapter 1, Scope and Administration-Deleted.
7.45.080 Chapter 2, Definitions - Added.
7.45.090 Chapter 2, Definitions - Amend.
7.45.100 Section 303, Chapter 3, Energy - Amended.
7.45.110 Section 304.2, Chapter 3, Determination of impacts based on locations - Amended.
7.45.120 Section 305.2, Chapter 3, Outdoor Swimming Pools and Spas - Amended.
7.45.130 Section 318.4, Chapter 3, Water Conservation - Added.
7.45.140 Section 901.2, Chapter 9, General - Deleted.
7.45.150 Section 1101.1, Chapter 11, Referenced Codes and Standards - Added.
7.45.160 Section 1101.2, Chapter 11, Application of Codes- Added.
7.45.170 Chapter 11, Referenced Standard-ANSI/APSP/ICC-13-2017 - Added.
7.45.010 Title
The International Swimming Pool and Spa Code adopted by Section 7.45.030 and the provisions of this chapter is the City swimming pool and spa code and may be cited as such and will be referred to in the International Swimming Pool and Spa Code and in this chapter as “this code.”
7.45.020 Purpose.
A. The purpose of this code is to establish minimum requirements to provide a reasonable level of safety, health, property protection and general welfare by regulating and controlling the design, construction, installation, quality of materials, location and maintenance or use of pools and spas.
B. The purpose of this code is not to create or otherwise establish or designate any particular class or group of persons who will or should be especially protected or benefited by the terms of this code.
1863
7.45.030 Adoption.
The 2021 International Swimming Pool and Spa Code, as published by the International Code Council a copy of which have been and are now filed in the Office of the Building Official, 100 Civic Plaza, Dublin, California, for use and examination by the public. Said codes are adopted by reference pursuant to Section 50022.4 et seq. of the Government Code of the State of California, and the codes are hereby adopted and incorporated as fully as if set out at length herein, and from the date on which the ordinance codified in this chapter shall take effect, the provisions thereof shall be controlling within the limits of the City of Dublin. except as hereinafter modified in Sections 7.45.060 through 7.45.170
7.45.040 Scope.
A The provisions of this code shall apply to the construction, alteration, movement, renovation, replacement, repair and maintenance of aquatic recreation facilities, pools, and spaces. The pools and spas covered by these codes are either permanent or temporary and shall be only those that are designed and manufactured to be connected to a circulation system and that are intended for swimming, bathing, or wading.
B. The permissive provisions of this code shall not be presumed to waive any limitations imposed by any other law, ordinance, rule or regulation. If two (2) or more pertinent limitations are not identical, those limitations shall prevail which provide greater safety to life, health, property or public welfare.
C. Swimming Pool Safety Act. The provisions contained in Appendix Chapter AX of the California Residential Code are mandatory to reflect the Swimming Pool Safety Act found in Health and Safety Code Section s115920 through 115929. Note: See Chapter 31, Section 3109 of the California Building Code.
7.45.050 Exceptions
The provisions of the swimming pool and spa code shall not apply to:
A. Flotation tank systems intended for sensory deprivation therapy.
7.45.060 Amendments to the International Swimming Pool and Spa Code.
The text of the International Swimming Pool and Spa Code, as adopted by section 7.45.030, is further amended to conform to the California Building Standards Code as follows:
Delete the following references Insert the following references International Building Code California Building Code
International Residential Code California Residential Code International Mechanical Code California Mechanical Code National Electrical Code or NFPA 70 California Electrical Code International Fire Code California Fire Code
International Plumbing Code California Plumbing Code
1864
International Existing Building Code California Existing Building Code International Zoning Code Zoning Ordinance of the City of Dublin International Energy Conservation
Code
California Energy Code
International Fuel Gas Code California Plumbing Code
Name of jurisdiction City of Dublin
Code official Building Official
“in accordance with Section 102.7 and
this section.”
“this section.”
7.45.070 Sections 101 through 109, and Sections 111 through 114, Chapter 1, Scope and Administration-Deleted.
Sections 101 through 109, and Sections 111 through 114, Chapter 1 are deleted.
7.45.080 Chapter 2, Definitions - Added.
The following definitions are added to read:
ANSI/APSP Performance Standard. ANSI/APSP performance standard means a standard that is accredited by the American National Standards Institute (ANSI) and published by the Association of Pool and Spa Professionals (APSP).
Approved Safety Pool Cover. Approved safety pool cover means a manually or power-operated safety pool cover that meets all of the performance standards of the American Society of Testing and Materials (ASTM), in compliance with standard F1346-91.
Enclosure. Enclosure means a fence, wall, or other barrier that isolates a swimming pool from access to the home.
Exit Alarms. Exit alarms means devices that make audible, continuous alarm sounds when any door or window, that permits access from the residence to the pool area that is without any intervening enclosure, in opened or is left ajar. Exist alarms may be battery operated or may be connected to the electrical wiring of the building.
Swimming Pool or Pool. Swimming pool of pool means any structure intended for swimming or recreational bathing that contains water over eighteen (18) inches deep. Swimming pool shall include in-ground and above ground structures and includes, but is not limited to, hot tubs, spaces, portable spas, and nonportable wading pools.
7.45.090 Chapter 2, Definitions - Amend.
The following definitions are amended to read:
1865
Public swimming pool. Public swimming pool means a swimming pool operated for the use of the general public with or without charge, or for the use of the members and guests of a private club. Public swimming pool does not include a swimming pool located on the ground of a private single-family home.
Suction Outlet. Suction outlet means a fitting or fixture typically located at the bottom or on the sides of a swimming pool that conducts water to a recirculating pump.
7.45.100 Section 303, Chapter 3, Energy - Amended.
Section 303. is deleted in its entirety and amended to read:
303 Energy. All pool and spa energy consumption shall meet the requirements in the California Energy Code.
7.45.110 Section 304.2, Chapter 3, Determination of impacts based on locations - Amended.
Section 304.2. is amended to read:
304.2 Determination of impacts based on location. Pools and spas in flood hazard areas indicated with in the City of Dublin shall comply with 304.2.1 or 304.2.2.
The remainder of section 304.2 is unchanged.
7.45.120 Section 305.2, Chapter 3, Outdoor Swimming Pools and Spas - Amended.
Section 305.2 is amended to read:
305.2 Outdoor swimming pools and spas. Other than those facilities regulated by the Swimming Pool Safety Act (Health and Safety Codes Sections 115920 through 115929), all outdoor pools and spas and indoor swimming pools shall be surrounded by a barrier that complies with Sections 305.2.1 through 305.7
7.45.130 Section 318.4, Chapter 3, Water Conservation - Added.
Section 318.4 is added to read:
318.4, Water conservation. Water conservation efficiency in residential and public pools, spas, portable spas, and swim spas shall be provided for in accordance with APSP 13.
7.45.140 Section 901.2, Chapter 9, General - Deleted.
Section 901.2 is deleted.
7.45.150 Section 1101.1, Chapter 11, Referenced Codes and Standards - Added.
1866
Section 1101.1 is added to read:
1101.1 Referenced codes and standards. The codes and
standards referenced in this code shall be those that are listed in this chapter and such codes and standards shall be considered to be part of the requirements of this code to the prescribed extent of each such reference. Where differences occur between provisions of this code and the referenced standards, the provision of this code shall be the minimum requirements.
7.45.160 Section 1101.2, Chapter 11, Application of Codes- Added.
Section 1101.2 is added to read:
1101.2 Application of Codes. Where the Residential Code is referenced in this code, the provisions of the Residential Code shall apply to related systems in detached one- and two-family dwellings and townhouses not more than three stories in height. Other related systems shall comply with the applicable Code or referenced standard.
7.45.170 Chapter 11, Referenced Standard-ANSI/APSP/ICC-13-2017 - Added.
Referenced standard ANSI/APSP/ICC-13-2017 is added to Chapter 11 Standard
Acronym
Standard Name Sections
Herein
Referenced
ANSI/APSP/ICC13-2017American National Standard for Water Conservation Efficiency in Residential and
Public Pools, space, Portable Spas and
Swim Spas
318.4
5196125.1
1867
Attachment 13
Exhibit J to the Ordinance
Chapter 7.46
EXISTING BUILDING CODE
Sections:
7.46.010 Title.
7.46.020 Purpose.
7.46.030 Adoption of Existing Building Codes.
7.46.040 Scope.
7.46.050 Exceptions.
7.46.060 Applicability.
7.46.070 Chapter 1 Division II, Administration-Deleted.
7.46.080 Section 202, Chapter 2, Definitions of Substantial Damage and Substantial Improvement.
7.46.090 Chapters 6 through 13-Deleted.
7.46.010 Title.
The building codes adopted by section 7.46.030 and the provisions of this Chapter shall constitute the Dublin Existing Building Code and may be referred to as such.
7.46.020 Purpose.
The intent of this code is to provide flexibility to permit the use of alternative approaches to achieve compliance with minimum requirements to provide a reasonable level of safety, health, property protection and general welfare insofar as they are affected by the repair, alteration, change of occupancy, addition and relocation of existing buildings. The purpose of this Code is not to create or otherwise establish or designate any particular class or groups of persons who will or should be especially protected or benefited by the terms of this Code.
7.46.030 Adoption of Existing Building Code.
A. The 2022 California Existing Building Code, Part 10, Title 24 of the California Code of Regulations, a portion of the California Building Standards Code, as defined in the California Health and Safety Code Section 18901 et. seq. (hereinafter referred to as the "State Code"), and any rules and regulations promulgated pursuant thereto including the International Existing Building Code, 2021 Edition, including Appendix Chapter A, as published by the International Code Council, and as referenced in and adopted pursuant to California Health and Safety Code Sections 17922 and 18935, (hereinafter referred to as the "IEBC") are hereby adopted and incorporated by reference herein.
The codes and standards referenced in this code shall be considered part of this code to the prescribed extent of each such reference. Where the extent of the reference to a referenced code or standard includes subject matter that is within the scope of this code or the Building, Mechanical, Plumbing, Housing, Fire or 1868
Energy Codes, the provisions of these codes as applicable, shall take precedence over the provisions in the referenced code or standard.
Copies of the adopted codes have been and are now filed in the Office of the Building Official, 100 Civic Plaza, Dublin, California, for use and examination by the public. Said codes are adopted by reference pursuant to Section 50022.4, et seq., of the Government Code of the State of California, and the codes are hereby adopted and incorporated as fully as if set out at length herein, and from the date on which this Ordinance shall take effect, the provisions thereof shall be controlling within the limits of the City of Dublin.
B. Notwithstanding the provisions of Section 7.46.030.A, the State Code and the IEBC are amended as set forth in Sections 7.46.070 through 7.46.090.
7.46.040 Scope.
A. The provisions of this Code shall apply to repair, alteration, change of occupancy, addition to and relocation of existing buildings.
B. The permissive provision of this Code shall not be presumed to waive any limitations imposed by any other law, ordinance, rule, or regulation. If two or more pertinent limitations are not identical, those limitations shall prevail which provide greater safety to life, health, property, or public welfare.
C. Where work regulated by this code is also regulated by the construction requirements for existing buildings in Chapter 11 of the Fire Code, such work shall comply with applicable requirements of both codes.
D. Buildings shall be made accessible to persons with disabilities as required by Title 24 California Code of Regulation. Whenever there is a conflict between the provisions of this Code and Title 24, California Code of Regulations with respect to the accessibility of buildings to persons with disabled, the provisions of Title 24 shall prevail.
7.46.050 Exceptions.
The provisions of this Code shall not apply to:
Detached one- and two-family dwellings and townhouses not more than three stories above grade plane in height with a separate means of egress, and their accessory structures not more than three stories above grade plane in height, shall comply with this code or the Residential Code.
7.46.060 Applicability.
This code shall apply to the repair, alteration, change of occupancy, addition and relocation of existing buildings, regardless of occupancy, subject to the criteria of Sections 7.46.060 A and 7.46.060 B.
A. Buildings not previously occupied. A building or portion of a building that has not been previously occupied or used for its intended purpose, in accordance with the laws in existence at the time of its completion, shall be permitted to comply with the provisions of the laws in existence at the 1869
time of its original permit unless such permit has expired, Subsequent permits shall comply with the Building or Residential Codes, as applicable, for new construction.
B. Buildings previously occupied. The legal occupancy of any building existing on the date of adoption of this code shall be permitted to continue without change, except as is specifically covered in this code, the Fire Code, or the Building Maintenance Code, or as is deemed necessary by the Building Official for the general safety and welfare of the occupants and the public.
7.46.070 Chapter 1 Division II, Administration-Deleted.
Chapter 1 Division II is deleted.
7.46.080 Section 202, Chapter 2, Definitions of Substantial Damage and Substantial Improvement.
The definitions of “Substantial Damage” and “Substantial Improvement” in Section 202 of the State Code are amended to read as follows:
Substantial Damage. Damage of any origin sustained by a structure whereby the cost of restoring the structure to its before-damaged condition would equal or exceed 50 percent of the market value of the structure before the damage occurred. The term also includes flood-related damage sustained by a structure on two separate occasions during a 10-year period for which the cost of repairs at the time of each such flood event, on average, equals or exceeds 25 percent of the market value of the structure before the damage occurred.
Substantial Improvement. Any one or more or any combination of repair, reconstruction, rehabilitation, alterations, addition or other improvement of a building or structure taking place during a 10-year period, the cumulative cost of which equals or exceeds 50 percent of the market value of the structure before the improvement or repair is started. For each building or structure, the 10-year period begins on the date of the first permit issued for improvement or repair of that building or structure subsequent to January 1, 2023. If the structure has sustained substantial damage, any repairs are considered substantial improvement regardless of the actual repair work performed. The term does not, however, included either:
1. Any project for improvement of a building required to correct existing health, sanitary or safety code violations identified by the building official and that are the minimum necessary to assure safe living conditions.
2. Any alteration of a historic structure provided that the alteration will not preclude the structure’s continued designation as a historic structure. 1870
7.46.090 Chapters 6 through 13-Deleted.
Chapters 6 through 13 are deleted.
5196169.1
1871
Attachment 14
Exhibit K to the Ordinance
Chapter 7.48
BUILDING MAINTENANCE CODE
Sections:
7.48.010 Title.
7.48.020 Purpose.
7.48.030 Adoption.
7.48.040 Scope.
7.48.050 Amendments to the International Property Maintenance Code.
7.48.060 Chapter 1, Scope and Administration-Deleted.
7.48.070 Sections 302.2, 302.3, 302.4 and 302.8, Chapter 3, Exterior Property Areas – Deleted.
7.48.080 Section 303.2, Chapter 3, Enclosures – Amended.
7.48.090 Section 304.14, Chapter 3, Insect Screens – Amended.
7.48.100 Section 304.16, Chapter 3, Under-Floor areas – Amended.
7.48.110 Sections 308.2.1.1, Chapter 3, Garbage Receptacles – Added.
7.48.120 Sections 309.1 and 309.2, Chapter 3, Pest Elimination – Amended.
7.48.130 Section 310.1 and 310.2, Chapter 3, Sanitation – Added.
7.48.140 Section 311, Chapter 3, Caretaker – Added.
7.48.010 Title.
The International Property Maintenance Code adopted by Section 7.48.030 and the provisions of this chapter are the City building maintenance code and may be cited as such and will be referred to in the International Property Maintenance Code and in this chapter as "this code."
7.48.020 Purpose.
A. The promotion and preservation of the public health, safety, and general welfare of the people of the City and the property situated therein have made necessary the adoption of the International Property Maintenance Code referred to in Section 7.48.030 in order to adequately safeguard life, health, property, and general welfare.
B. The purpose of this code is not to create or otherwise establish or designate any particular class or group of persons who will or should be especially protected or benefited by the terms of this code.
7.48.030 Adoption.
The 2022 International Property Maintenance Code, including Appendix Chapter A, as published by the International Code Council a copy of which have been and are now filed in the Office of the Building Official, 100 Civic Plaza, Dublin, California, for use and examination by the public. Said codes are adopted by reference pursuant to Section 50022.4 et seq. of the Government Code of the State of California, and the codes are hereby adopted and incorporated as fully as if set out at length herein, and from the date on which the ordinance codified in this chapter shall take effect, the provisions 1872
thereof shall be controlling within the limits of the City of Dublin. except as hereinafter modified in Sections 7.48.050 through 7.48.140.
7.48.040 Scope.
A. The provisions of this code shall apply to all buildings or portions thereof used, or designed or intended to be used, for human habitation. Such occupancies in existing buildings may be continued as provided in Section 7.28.240, except such as are found to be substandard as defined in this code.
B. Where any building or portion thereof is used or intended to be used as a combination apartment house-hotel, the provisions of this code shall apply to the separate portions as if they were separate buildings. Every rooming house or lodging house shall comply with all the requirements of this code for dwellings.
7.48.050 Amendments to the International Property Maintenance Code.
The text of the International Property Maintenance Code, as adopted by section
7.48.030, is further amended to conform to the California Building Standards Code as follows:
Delete the following references Insert the following references International Building Code California Building Code California Residential Code
International Mechanical Code California Mechanical Code National Electrical Code or NFPA 70 California Electrical Code International Fire Code California Fire Code
International Plumbing Code California Plumbing Code
International Existing Building Code California Existing Building Code International Zoning Code Zoning Ordinance of the City of Dublin International Fuel Gas Code California Plumbing Code
Name of jurisdiction City of Dublin
7.48.060 Chapter 1, Scope and Administration-Deleted.
Chapter 1 is deleted.
7.48.070 Sections 302.2, 302.3, 302.4 and 302.8, Chapter 3, Exterior Property Areas – Deleted.
Sections 302.2, 302.3, 302.4 and 302.8. are deleted
7.48.080 Section 303.2, Chapter 3, Enclosures – Amended.
Section 303.2 is amended to read:
303.2 Enclosures. Private swimming pools, hot tubs, and spas enclosures shall meet the requirements of Section 3109.2 California Building Code, California Swimming Pool Safety Act and 7.45.120.
1873
7.48.090 Section 304.14, Chapter 3, Insect Screens – Amended. 304.14 Insect screens. Every door, window and other outside opening required for ventilation of habitable rooms, food preparation areas, food service areas or any areas where products to be included or utilized in food for human consumption are processed, manufactured, packaged or stored shall be supplied with approved tightly fitting screens of minimum 16 mesh per inch (16 mesh per 25 mm), and every screen door used for insect control shall have a self-closing device in good working condition.
Exception: Screens shall not be required where other approved means, such as air curtains or insect repellent fans, are employed.
7.48.100 Section 304.16, Chapter 3, Under-Floor areas – Amended.
Section 304.16 is amended to read:
304.16 Under-Floor areas. Under-floor access doors and ventilation openings shall be maintained to prevent the entrance of rodents, rain and surface drainage water. Doors shall be tight fitting and ventilation openings shall be properly screened with corrosion-resistant wire mesh having openings not exceeding 1/4 inch in any dimension or alternate approved materials pursuant to current CBC 1203.4.1.
7.48.110 Sections 308.2.1.1, Chapter 3, Garbage Receptacles – Added.
Section 308.2.1.1 is added to read:
308.2.1.1 Garbage Receptacles. An adequate number of appropriate receptacles with close fitting covers for garbage and rubbish as may be considered necessary by the enforcing agency shall be provided for the occupant of every dwelling unit by the owner or operator of every apartment house, hotel, or combination thereof. Each receptacle shall be kept in a clean condition and good repair.
7.48.120 Sections 309.1 and 309.2, Chapter 3, Pest Elimination – Amended.
Sections 309.1 and 309.2 are amended to read:
309.1 Infestation. All structures shall be kept free from insect, rodent and vermin infestation. When an insect, rodent or vermin infestation is brought to the attention of the code official, he or she may require the owner or agent having charge or control of the building, lot or premises to hire a licensed exterminator or other qualified professional to inspect the building, lot or premises and provide a written report verifying the presence and severity of such infestation including in the report a recommendation for proper extermination of the infestation. All structures in which insect, rodent or vermin infestations are found shall be promptly exterminated by approved processes that will not be injurious to human health.
After the extermination of the infestation is complete, the code official may request 1874
a written notice from the licensed exterminator or other qualified professional attesting to the completion and success of the recommended extermination procedures. After the infestation is eliminated, proper precautions shall be taken to prevent reinfestation.
309.2 Owner. The owner of any structure shall be responsible for extermination within the structure prior to renting or leasing the structure. The owner of a structure or premises containing a dwelling unit, multiple occupancy, rooming house or a nonresidential structure shall be responsible for maintaining the structure and premises in a rodent or pest-free condition. If an infestation is caused by an occupant substantially failing to properly maintain their occupied area of the structure or premises as clean and sanitary as the condition of the structure or premises permits, the occupant and owner shall be responsible for pest elimination. For as long as the occupant’s failure either substantially causes an unlivable condition to occur, or substantially interferes with the owners’ ability to remedy the condition, the owner does not have to remedy the condition. Where the infestation is caused by defects in the structure, the owner shall be responsible for extermination.
7.48.130 Section 310.1 and 310.2, Chapter 3, Sanitation – Added.
Sections 310.1 is added to read
310.1 Bedding. In every room for rent, apartment house or hotel every part of every bed, including the mattress, sheets, blankets, and bedding shall be kept in a clean, dry and sanitary condition, free from filth, urine, or other foul matter; and from infection of lice, bed-bugs, or other insects. The bed linen shall be changed before a new guest occupies the dwelling unit.
7.48.140 Section 311, Chapter 3, Caretaker – Added.
Section 311.1 is added to read
311 Caretaker. A manager, janitor, housekeeper, or other responsible person shall reside upon the premises and shall have charge of every apartment house in which there are sixteen (16) or more apartments and of every hotel in which there are twelve (12) or more guest rooms, in the event that the owner of any such apartment house or hotel does not reside upon said premises. If the owner does not reside upon the premises of an apartment house in which there are more than four (4) but less than sixteen (16) apartments, a notice stating his name and address, or name and address of his agent shall be posted in a conspicuous place on the premises.
5196173.1
1875
Attachment 15
Exhibit L to the Ordinance
Chapter 7.94
GREEN BUILDING
Sections:
7.94.010 Title.
7.94.020 Purpose.
7.94.030 Adoption of the Green Building Code.
7.94.040 Scope.
7.94.050 Section 202, Chapter 2 Definitions – Amended.
7.94.060 Section 4.106.4 Electric vehicle (EV) charging for new construction – Deleted and Replaced.
7.94.070 Sections 4.106.5, 4.106.5.1, and 4.106.5.2 All Electric Buildings – Added.
7.94.080 Section 4.107.1, Division 4.1, Chapter 4, Future access for solar systems-Added.
7.94.090 Sections 5.106.5.3 and 5.106.5.3.1 Electric vehicle (EV) charging. – Deleted and Replaced.
7.94.100 Section 5.106.13, 5.106.13.1 and 5.106.13.2 All electric buildings. – Added.
7.94.110 Section 5.107.1, Division 5.1, Chapter 5, Future access for solar systems-Added.
7.94.010 Title.
The green building standards codes adopted by Section 7.94.030 and the provisions of this Chapter shall constitute the Dublin Green Building Code and may be referred to as such.
7.94.020 Purpose.
A. To improve public health, safety, and general welfare by enhancing the design and construction of buildings through the use of building concepts having a reduced negative impact or positive environmental impact and encouraging sustainable construction practices in the following categories:
1. Planning and design
2. Energy efficiency
3. Water efficiency and conservation
4. Material conservation and resource efficiency
5. Environmental quality
B. The purpose of this Code is not to create or otherwise establish or designate any particular class or groups of persons who will or should be especially protected or benefited by the terms of this Code.
1876
7.94.030 Adoption of the Green Building Code.
A. The 2022 California Green Building Standards Code, Part 11, Title 24 of the California Code of Regulations, a portion of the California Building Standards Code, as defined in the California Health and Safety Code Section 18901 et. seq. (hereinafter referred to as the "State Code"), and any rules and regulations promulgated pursuant thereto, as referenced in and adopted pursuant to California Health and Safety Code Sections 17922 and 18935, are hereby adopted and incorporated by reference herein.
Copies of the adopted codes have been and are now filed in the Office of the Building Official, 100 Civic Plaza, Dublin, California, for use and examination by the public. Said codes are adopted by reference pursuant to Section 50022.4, et seq., of the Government Code of the State of California, and the codes are hereby adopted and incorporated as fully as if set out at length herein, and from the date on which this Ordinance shall take effect, the provisions thereof shall be controlling within the limits of the City of Dublin.
B. Notwithstanding the provisions of Section 7.94.030.A, the State Code is amended as set forth in Sections 7.94.050 through 7.94.080.
7.94.040 Scope.
A. The provisions of this Code shall apply to the planning, design, operation, construction, use and occupancy of every newly constructed building or structure, unless otherwise indicated in this Code, within the City.
B. It is not the intent that this Code substitute or be identified as meeting the certification requirements of any green building program.
7.94.050 Section 202, Chapter 2 Definitions – Amended.
The following definitions are hereby added to Section 202 of the State Code to read as follows:
ALL-ELECTRIC BUILDING. A building that contains no combustion equipment or plumbing for combustion equipment within the building or building property lines, and instead uses electric appliances for service.
COMMERCIAL FOOD HEAT-PROCESSING EQUIPMENT. Equipment used in a food establishment for heat-processing food or utensils and that produces grease vapors, steam, fumes, smoke, or odors that are required to be removed through a local exhaust ventilation system, as defined in the California Mechanical Code.
COMBUSTION EQUIPMENT. Any equipment or appliance used for space heating, water heating, cooking, clothes drying and/or lighting that uses fuel gas. 1877
ELECTRIC HEATING APPLIANCE. A device that produces heat energy to create a warm environment by the application of electric power to resistance elements, refrigerant compressors, or dissimilar material junctions, as defined in the California Mechanical Code.
FUEL GAS. A gas that is natural, manufactured, liquefied petroleum, or a mixture of these.
7.94.060 Section 4.106.4 Electric vehicle (EV) charging for new construction – Deleted and Replaced.
Section 4.106.4 is deleted and replaced with Section A4.106.8 to read:
A4.106.8 Electric vehicle (EV) charging for new construction is adopted as mandatory at the Tier 2 level.
7.94.070 Sections 4.106.5, 4.106.5.1, and 4.106.5.2 All Electric Buildings – Added.
Sections 4.106.5, 4.106.5.1, and 4.106.5.2 are added to read:
4.106.5 All-electric buildings. New construction buildings and qualifying alteration projects shall comply with Section 4.106.5.1 or 4.106.5.2 so that they do not use combustion equipment or are ready to accommodate installation of electric heating appliances.
4.106.5.1. New construction and qualifying alteration projects. All newly constructed buildings shall be all-electric buildings. Qualifying alteration projects shall be limited to additions or alterations that remove 50 percent or more of the existing exterior walls of a dwelling and additions that increase the square footage of the structure by more than 50 percent.
The final determination whether a project meets the definition of a qualifying alteration project shall be made by the Building Official Exception:
If the applicant establishes that there is not an all-electric prescriptive compliance pathway for the building under the California Building Energy Efficiency Standards, and that the building is not able to achieve the performance compliance standard applicable to the building under the Energy Efficiency Standards using commercially available technology and an approved calculation method, then the Building Official may grant a modification. The applicant shall comply with the following and Section 4.106.5.2.
Inactive Fuel Gas Infrastructure may be extended to spaces that are anticipated to qualify for the exceptions contained in this chapter.
The inactive Fuel Gas Infrastructure shall not be activated, have a 1878
meter installed, or otherwise used unless the exemptions specified in this chapter have been confirmed as part of the issuance of a building permit. If the Fuel Gas Infrastructure is no longer serving one of the exceptions contained in this chapter, it shall either be capped, otherwise terminated, or removed by the entity previously entitled to the exemption, in a manner pursuant to all applicable Codes.
The Building Official shall have the authority to approve alternative materials and methods of construction as per the Dublin Municipal Code, Chapter 7.28.
4.106.5.2 Requirements for combustion equipment.
Where combustion equipment is allowed under subsection 4.106.5.1, the construction drawings shall indicate electrical infrastructure and physical space accommodating the future installation of an electrical heating appliance in the following ways, as certified by a registered design professional or licensed electrical contractor:
1. Branch circuit wiring, electrically isolated and designed to serve all electrical heating appliances in accordance with manufacturer requirements and the California Electrical Code, including the appropriate voltage, phase, minimum amperage, and an electrical receptacle or junction box within five feet of the appliance that is accessible with no obstructions. Appropriately sized conduit may be installed in lieu of conductors; and
2. Labeling of both ends of the unused conductors or conduit shall be with “For Future Electrical Appliance”; and
3. Reserved circuit breakers in the electrical panel for each branch circuit, appropriately labeled (i.e. “Reserved for Future Electric Range”), and positioned on the opposite end of the panel supply conductor connection; and
4. Connected subpanels, panelboards, switchboards, busbars, and transformers shall be sized to serve the future electrical heating appliances. The electrical capacity requirements shall be adjusted for demand factors in accordance with the California Electric Code; and
5. Physical space for future electrical heating appliances, including equipment footprint, and if needed a pathway reserved for routing of ductwork to heat pump evaporator(s), shall be depicted on the construction drawings. The footprint necessary for future electrical heating appliances may overlap with non-structural partitions and with the location of currently designed combustion equipment.
1879
7.94.080 Section 4.107.1, Division 4.1, Chapter 4, Future access for solar systems-Added.
A new Section 4.107.1 is added to read:
4.107.1 Future Access for Solar Systems. A minimum one-inch (25.4 mm) electrical conduit shall be provided from the electrical service equipment to the solar zone as defined by the California Energy Code, Title 24, Part 6, Section 110.10. Where a solar zone is not required by the California Energy Code, the conduit location shall be subject to approval of the Building Official.
Exception: Where solar is installed as part of the original construction and prior to first occupancy.
7.94.090 Sections 5.106.5.3 and 5.106.5.3.1 Electric vehicle (EV) charging. – Deleted and Replaced.
Sections 5.106.5.3 and 5.106.5.3.1 are deleted and replaced with Section A5.106.5.3 to read:
Section A5.106.5.3 Electric vehicle (EV) charging for new construction is adopted as mandatory at the Tier 2 level.
7.94.100 Section 5.106.13, 5.106.13.1 and 5.106.13.2 All electric buildings. – Added.
Section 5.106.13, 5.106.13.1 and 5.106.13.5.2 are added to read:
5.106.13 All-electric buildings. New construction buildings and qualifying alteration projects shall comply with Section 5.106.13.1 or 5.106.13.2 so that they do not use combustion equipment or are ready to facilitate future electrification.
5.106.13.1. New construction and qualifying alteration projects. All newly constructed buildings shall be all-electric buildings. Qualifying alteration projects shall be limited to additions or alterations that remove 50 percent or more of the existing exterior walls of a structure and additions that increase the square footage of the structure by more than 50 percent.
Tenant improvements shall not be considered new construction. The final determination whether a project meets the definition of qualifying alteration project shall be made by the Building Official.
Exceptions:
1. Nonresidential buildings containing kitchens located in a place of public accommodation, as defined in the California Building Code Chapter 2, may apply to the Building Official for a modification to install commercial food heat-processing equipment served by fuel 1880
gas. The Building Official may grant the modification, provided the following findings are made:
a) The applicant has a business-related need to cook with combustion equipment; and
b) The applicant has installed energy efficient equipment based on Energy Star or California Energy Wise
qualifications, as available.
c) The applicant will comply with Section 5.106.13.2.
2. If the applicant establishes that there is not an all-electric prescriptive compliance pathway for the building under the California Building Energy Efficiency Standards, and that the building is not able to achieve the performance compliance standard applicable to the building under the Energy Efficiency Standards using commercially available technology and an approved calculation method, then the Building Official may grant a modification. The applicant shall comply with following and Section
5.106.13.2
Inactive Fuel Gas Infrastructure may be extended to spaces that are anticipated to qualify for the exceptions contained in this chapter. The inactive Fuel Gas Infrastructure shall not be activated, have a meter installed, or otherwise be used unless the exemptions specified in this chapter have been confirmed as part of the issuance of a building permit. If the Fuel Gas Infrastructure is no longer serving one of the exceptions contained in this chapter, it shall either be capped, otherwise terminated, or removed by the entity previously entitled to the exemption, in a manner pursuant to all applicable Codes.
The Building Official shall have the authority to approve alternative materials and methods of construction as per the Dublin Municipal Code, Chapter 7.28.
5.106.13.2. Requirements for combustion equipment.
Where combustion equipment is allowed under Subsection 5.106.13.1, the construction drawings shall indicate electrical infrastructure and physical space accommodating the future installation of an electrical heating appliance in the following ways, as certified by a registered design professional or licensed electrical contractor:
1. Branch circuit wiring, electrically isolated and designed to serve all electrical heating appliances in accordance with manufacturer requirements and the California Electrical Code, including the appropriate voltage, phase, minimum amperage, and an electrical receptacle or junction box within five feet of the appliance that is accessible with no obstructions. Appropriately sized conduit may be installed in lieu of conductors; and 1881
2. Labeling of both ends of the unused conductors or conduit shall be with “For Future Electrical Appliance”; and
3. Reserved circuit breakers in the electrical panel for each branch circuit, appropriately labeled (i.e. “Reserved for Future Electric Range”), and positioned on the opposite end of the panel supply conductor connection; and
4. Connected subpanels, panelboards, switchboards, busbars, and transformers shall be sized to serve the future electrical heating appliances.
The electrical capacity requirements shall be adjusted for demand factors in accordance with the California Electric Code; and
5. Physical space for future electrical heating appliances, including equipment footprint, and if needed a pathway reserved for routing of ductwork to heat pump evaporator(s), shall be depicted on the construction drawings.
The footprint necessary for future electrical heating appliances may overlap with non-structural partitions and with the location of currently designed combustion equipment.
7.94.110 Section 5.107.1, Division 5.1, Chapter 5, Future access for solar systems-Added.
A new Section 5.107.1 is added to read:
5.107.1 Future Access for Solar Systems. Install conduit from the solar zone as defined by the California Energy Code, Title 24, Part 6, Section 110.10 to a location within the building identified as suitable for future installation of a charge controller (regulator) and inverter.
Exception: Where solar is installed as part of the original construction and prior to first occupancy.
5196068.1
1882
Attachment 16
STAFF REPORT
CITY COUNCIL
Agenda Item 4.2
DATE: November 1, 2022
TO: Honorable Mayor and City Councilmembers
FROM: Linda Smith, City Manager
SUBJECT: Updates to the City’s Construction and Fire Codes in Accordance with Requirements of State Law
Prepared by: Gregory Shreeve Sr., Chief Building Official EXECUTIVE SUMMARY:
The City Council will consider introducing an Ordinance repealing the 2019 California Building Standards Code and adopting the 2022 California Building Code and setting a public hearing for November 15, 2022. In connection with this action, the City Council will be asked to approve findings relating to the City’s local amendments to the California Building Standards Code. The 2022 Edition of the California Building Standards Code was approved by the California Building Standards Commission earlier this year and will go into effect on January 1, 2023. The City must adopt an Ordinance incorporating the updated provisions to ensure accuracy and alignment with state law.
STAFF RECOMMENDATION:
Take the following actions: 1) Waive the first reading and INTRODUCE the Ordinance Repealing and Replacing Chapters 5.08 (Fire Code), 7.28 (Building Regulation Administration Code), 7.32 (Building Code), 7.34 (Residential Code), 7.36 (Electrical Code), 7.40 (Plumbing Code), 7.44 (Mechanical Code), 7.48 (Building Maintenance Code) and 7.94 (Green Building Code) of the Dublin Municipal Code, and Repealing Chapter 7.24 (Flood Control) and Adopting Chapter 7.24 (Floodplain Management Regulations and Adding Chapter 7.46 (Existing Building Code) to the Dublin Municipal Code, in Order to Adopt by Reference and Amend Provisions of the 2022 Edition of the California Building Standards Code, Title 24, California Code of Regulations, and Adding Chapter 7.45 (Swimming Pool and Spa Code) to the Dublin Municipal Code in Order to Adopt by Reference and Amend Provisions of the 2021 Edition of the International Swimming Pool and Spa Code; and 2) Set the public hearing for November 15, 2022, to waive the second reading and adopt said Ordinance and adopt the Resolution Approving the Finding of Necessity for Amendments to the 2022 California Building Standards Code.
1883
FINANCIAL IMPACT:
The cost associated with implementing the new codes, such as materials and training, have been included in the Fiscal Year 2022-23 Budget.
DESCRIPTION:
Background
The California Building Standards Commission, along with other State agencies, reviews and amends Title 24 of the California Building Standards Code (CBSC) approximately every three years. The CBSC contains several codes including the California Building Code and the California Electrical Code. Each of these codes are applicable and enforceable at the local level. The 2022 Edition of the CBSC was approved by the California Building Standards Commission earlier this year and will go into effect on January 1, 2023. The City must adopt an ordinance incorporating the updated provisions to ensure accuracy and alignment with state law.
Local jurisdictions may amend the provisions of the CBSC with the adoption of a resolution finding that the changes are necessary to account for local climatic, geological, or topographical conditions. However, these amendments must be at least as stringent as those outlined in the CBSC.
The City Council made several such amendments with the adoption of the 2019 Edition of the codes. These previously adopted local amendments have been incorporated into the proposed code update adopting the 2022 Edition, with several modifications as discussed later in this Staff Report.
Proposed Ordinance
The proposed Ordinance will amend Chapters 5.08, 7.24, 7.28, 7.32, 7.34, 7.36, 7.40, 7.44, 7.48 and
7.94 of the Dublin Municipal Code (DMC) and add Chapters 7.45 and 7.46 to the DMC. The proposed Ordinance does not adopt the permit fee tables in the codes, thus maintaining the City’s current permit fees. The proposed Ordinance will supersede and replace the previously adopted codes, and will benefit the City by:
1. Ensuring the City’s compliance with the States building standards laws;
2. Ensuring consistency with neighboring jurisdictions and the Bay Area;
3. Providing internally consistent, coherent, and easier-to-use codes; and
4. Making it easier for the public to review and to understand the model code requirements.
This report focuses on Staff-recommended local amendments to the 2022 Edition of the code, and modifications to local amendments that were previously adopted by the City Council during the last code update.
Analysis
The following is an overview of the proposed local amendments to the Dublin Municipal Code.
Attachments 1 and 2 provide a complete list of all proposed local amendments to the Construction and Fire Codes, and associated findings. The draft Ordinance is provided as Attachment 3. 1884
Fire Code – DMC Chapter 5.08
The amendments to the Fire Code (Attachment 4) are required to adopt the latest California Fire Codes. Staff recommends deleting the following local amendment that was previously adopted by the City Council:
1. Section 5.08.120, the table for separation distances between wood pallet stacks and buildings. This requirement is now in the California Fire Code.
Floodplain Management Regulations (Formally the Flood Control Chapter) – DMC Chapter 7.24 The adoption of the Floodplain Management Regulations is required as a replacement for the Flood Control Chapter. The City’s existing Flood Control Chapter is based on an outdated version of the Floodplain Management Regulations of the Federal Emergency Management Agency (FEMA) and the California Department of Water Resources (DWR).
Staff recommends the following higher standards for the model Floodplain Management Regulations be included in this code:
1. Cumulative Substantial Improvement — These amendments will require a review of the 10-year history of permitted work on a property. The 10-year period will begin January 1, 2023. This is a change from current practice of reviewing a three-year history of permits.
As the beginning date of the review period changes to January 1, 2023, this new requirement will not affect projects until after January 1, 2026. One of the objectives of the National Flood Insurance Program (NFIP) is to reduce the long-term exposure of buildings to flood damage. To achieve this objective, the NFIP requires that existing buildings be brought into compliance if improvements, including additions and repairs, are determined to be Substantial Improvement. If the cost of proposed improvements equals or exceeds 50 percent of the market value of the building before improvements are started, the building will be required to be brought into compliance for new construction.
2. Dwelling Design — new one- and two-family dwellings and substantial improvements to these buildings that are located in a flood hazard area will be required to be designed to a higher standard to account for the potential for flood loads. This modification is necessary to account for rising sea levels that have the potential to create conditions such as fastmoving floodwater, flood depths greater than a few feet, wave action, and potential scour and erosion.
3. Nonconversion agreements — these amendments will require builders of elevated buildings located in a flood plain to record a nonconversion agreement. The nonconversion agreement is used to inform buyers of the property that the area below the elevated building is limited to parking of vehicles, storage, and building access. NFIP flood insurance coverage is more expensive if buildings have enclosed areas and coverage of enclosures is limited. This regulation will require builders and or property owners to record a signed nonconversion agreement to acknowledge the restrictions on use of enclosures below elevated buildings and to agree not to modify or convert the enclosures. The objective is to reduce the likelihood that owners, including future owners, might convert enclosures to 1885
uses other than those permitted.
4. Repetitive Flood Damage loss — one of the objectives of the NFIP is to break the cycle of damage, repair, and damage again. To achieve this objective, the NFIP requires that existing buildings be brought into compliance when they incur Substantial Damage. A building is determined to have incurred Substantial Damage if it is damaged by any cause and the cost to repair the building to its pre-damage condition equals or exceeds the 50 percent of the market value of the building before the damage occurred. Per the NFIP, when communities adopt a definition for Substantial Damage that includes “repetitive loss,” owners of NFIP – insured structures that sustain repetitive flood damage may also be eligible to apply for Increased Cost of Compliance funds even if the damage does not meet the standard 50 percent threshold for Substantial Damage by a single-event. For property owners to qualify, communities must adopt and enforce the repetitive loss provision on all buildings, not just those that are covered by NFIP flood insurance.
5. Determination of Base Flood Elevation (BFE) — Dublin has areas within the City where the Flood Insurance Rate Map (FIRM) does not show the base flood elevations. These areas are called “unnumbered Zone A” or “approximate Zone A.” The NFIP regulations state that where flood elevation data has not been provided, communities must “obtain, review, and reasonably utilize any base flood elevation and floodway data available from a Federal, State, or other source.” However, some data from other sources is old and out of date and may not reasonably represent current flood hazards. This modification will require the applicant to include base flood elevation data prepared by a qualified professional engineer in accordance with accepted techniques. The modification is necessary to reasonable protect new construction from flood damage caused by rising sea levels.
The DWR, on behalf of the State and FEMA, has reviewed and approved the proposed regulations.
Building Regulations Administration Code – DMC Chapter 7.28 The amendments to the Building Regulations Administrative Code (Attachment 6) are required to remain current with State Law. Staff recommends the following modifications and additions to local amendments previously adopted by the City Council:
1. Sections 7.28.100 and 7.28.110 — add definitions and process requirements for determining substantially improved and substantially damaged existing buildings in a flood hazard zone. This action is necessary to codify existing procedures and to be consistent with DMC chapter 7.24, Floodplain Management Regulations.
2. Section 7.28.120 — add the Swimming Pool and Spa Code and the Existing Building Code regulated by the Building Regulations Administration Code. The modification is necessary to codify the administration regulations for these two codes.
3. Section 7.28.260 — add the Swimming Pool and Spa Code and the Existing Building Code to the Code Conflicts section. The modification is necessary to codify the administration regulations for potential conflicts between the State Codes and City amendments. 1886
4. Section 7.28.330 — modify the permit application submittal process to require all plans to be submitted in an electronic format. This modification is necessary to codify current practices.
5. Section 7.28.390 — add a requirement for the owner or the owner’s authorized agent to post the live loads of floors under prescribed conditions. This addition is necessary to remain current with State Law.
6. Section 7.28.600 — amend the notifications of inspections as follows:
a. Inspection #F, Lowest Floor Elevation clarifying that the requirement is triggered by either the Floodplain Management Regulations (7.24) requirements, the Building Code (7.32) or Residential Code (7.34). The requirements do not change. b. Inspection #M, adding the requirement for tall wood buildings connection protection inspection. This is necessary to remain current with State Law and does not change the requirement.
c. Inspection #Q, adding a requirement for Fire and Smoke – Resistant Penetrations inspections. This is necessary to remain current with State Law and does not change the requirement.
d. Inspection #U, adding a requirement for Flood Hazard Documentation. This is necessary to remain current with State Law and Federal Regulations. This does not change the current requirement.
Building Code – DMC Chapter 7.32
The amendments to the Building Code (Attachment 7) are required to adopt the latest California Building Codes. Staff recommends a modification to the following local amendment that was previously adopted by the City Council:
1. Section 7.32.230 — update Wall Bracing requirements to include newly adopted forms of seismic sheathing of walls. This modification is necessary to address Dublin’s seismic risk and to be consistent with neighboring jurisdictions.
In addition, Staff recommends the following new local amendments to this code:
1. Section 7.32.120 — add definitions for determination or substantially improved and substantially damaged existing buildings in a flood hazard zone. This action is necessary to codify existing procedures and to be consistent with DMC chapter 7.24, Floodplain Management Regulations.
2. Section 7.32.290 — modify to update the proper procedures for violations of the Floodplain Management Regulations requirements chapter in this code. This is necessary to maintain consistency in the DMC.
3. Section 7.32.300 — modify to designate the floodplain administrator. This is necessary to maintain consistency in the DMC.
1887
Residential Code – DMC Chapter 7.34
The amendments to the Residential Code (Attachment 8) are required to adopt the latest California Residential Code. Staff recommends the following modifications to local amendments previously adopted by the City Council:
1. Section 7.34.040 — modify to update the live/work exception. This modification is necessary to remain consistent with State Law.
2. Section 7.34.070C — modify to include an exception to the separate gas and electrical meter requirement by adding an exception for Junior Accessory Dwelling Units. This modification is necessary to remain consistent with State Law.
3. Section 7.34.120 — modify to update the design standards for buildings constructed under this code. This modification is necessary to remain consistent with State Law.
In addition, Staff recommends the following new local amendments to this code:
1. Section 7.34.110 — add definitions for determination or substantially improved and substantially damaged existing buildings in a flood hazard zone. This action is necessary to codify existing procedures and to be consistent with DMC chapter 7.24, Floodplain Management Regulations.
2. Sections 7.34.130 and 7.34.170 — modify to update the design requirements in flood hazard areas. This action is necessary to be consistent with DMC chapter 7.24, Floodplain Management Regulations.
Further, Staff recommends deleting the following local amendment that was previously adopted by the City Council:
1. Section 7.34.140 — originally deleted the fire sprinkler provisions in this code and referenced the Fire Code. This deletion is no longer necessary as the two codes are now consistent.
Electrical Code – DMC Chapter 7.36
The amendments to the Electrical Code (Attachment 9) are required to adopt the latest California Electrical Codes. The existing modification setting standards for the location of electrical receptacles in office spaces has been brought forward.
Plumbing Code – DMC Chapter 7.40
The amendments to the Plumbing Code (Attachment 10) are required to adopt the latest California Plumbing Codes. The existing local amendment restricting the installation of water piping under a concrete slab has been brought forward. Staff recommends one deletion from this code:
1. Section 7.40.090 — originally deleted the fire sprinkler provisions in this code and referenced the Fire Code. This deletion is no longer necessary as the two codes are now 1888
consistent.
Mechanical Code – DMC Chapter 7.44
The amendments to the Mechanical Code (Attachment 11) are required to adopt the latest California Mechanical Codes. The existing local amendment deleting the administrative chapter has been brought forward.
Swimming Pool and Spa Code – DMC Chapter 7.45
The adoption of the Swimming Pool and Spa Code (Attachment 12) is required to adopt the International Swimming Pool and Spa Code (ISPSC) as a replacement for the swimming pool construction and safety codes that have been removed from the International Building Code, which is the basis for the California Building Code, and placed in this new code. Staff recommends the following modifications to the ISPSC to address conflicts with City and State Codes:
1. 7.45.060 — add this to modify the references to the International and National Codes to the California Codes. This is necessary to stay current with State Law.
2. 7.45.070 — modify to delete administrative sections of the ISPSC. This is necessary to be consistent within the City’s codes.
3. 7.45.080 — modify to add definitions that are found in State Law that are missing from the ISPSC. This is necessary to remain consistent with State Law.
4. 7.45.090 — modify to amend definitions that are different between the ISPSC and State Law. This is necessary to remain consistent with State Law.
5. 7.45.100 — modify to amend the energy requirements in the ISPSC in favor of the California Energy Code. This is necessary to remain consistent with State Law and the 2022 California Energy Code.
6. 7.45.110 — modify to clarify the requirements of swimming pools and spas located in a flood hazard area. This is necessary to remain consistent with chapter 7.24 Floodplain Management Regulations.
7. 7.45.120 — modify to require all swimming pools to have barriers installed. This amendment is necessary to remain consistent with State Law.
8. 7.45.130 — modify to include water conservation efficiency in residential and public pools and spas. This is necessary because of the City of Dublin has a dry period of at least five months each year. Additionally, the area is subject to occasional drought and this amendment is necessary to remain consistent with State Law.
9. 7.45.140 — modify to delete chapter 9 for permanent spas. This is necessary because this chapter provides exceptions from code requirements that are in conflict with State Law.
10. 7.45.150 — add this to adopt the referenced codes and standards listed in the ISPSC. This 1889
is necessary to provide the tools necessary for the contractor and staff to properly enforce this code.
11. 7.45.160 — modify to clarify that where the code references the Residential Code, those provision are related to systems in detached one- and two-family dwellings and townhouses not more than threes stories in height. This amendment is necessary to remain consistent with State Law.
12. 7.45.170 — add this to adopt the American National Standard for Water conservation efficiency in pools and spas. This is necessary because of the City of Dublin has a dry period of at least five months each year. Additionally, the area is subject to occasional drought and this amendment is necessary to remain consistent with State Law.
Existing Building Code – DMC Chapter 7.46
The amendments to the Existing Building Code (Attachment 13) are required to adopt the California Existing Building Code (CEBC). Staff is recommending the following modification to this code:
1. Section 7.46.080 — add definitions for determination or substantially improved and substantially damaged existing buildings in a flood hazard zone. This action is necessary to codify existing procedures and to be consistent with DMC chapter 7.24, Floodplain Management Regulations.
Building Maintenance Code – DMC Chapter 7.48
The amendments to the Building Maintenance Code (Attachment 14) are required to adopt the latest International Property Maintenance Codes. The existing local amendments have been brought forward.
Green Building Code – DMC Chapter 7.94
The amendments to the Green Building Code (Attachment 15) are required to adopt the latest California Green Building Standards Code. The City’s amendment for Electric Vehicle (EV) Parking to be installed at the Tier 2 has been brought forward. Bringing this amendment forward will meet and, in some cases, exceed the City’s Climate Action Plan (CAP) requirements under measure SM1. Staff recommends the following new amendments to this code:
1. Section 7.94.050, 7.94.070 and 7.94.100 — add these to include requirements for new buildings to be all electric with exceptions. The exceptions in the recommendations include: a) multi-family and commercial projects where the design team has provided evidence that an all-electric building is unable to meet established requirements under the California Building Energy Efficiency Standards; and b) commercial buildings containing kitchens or having the potential to contain kitchens, upon application, may install gas to the building for use in the kitchen areas. These modifications are necessary to limit the greenhouse gas (GHG) emissions from natural gas. It is estimated that without the requirement for all-electric buildings, new construction will add over three million therms of natural gas use in Dublin by 2045. In addition, all-electric buildings have been found to be less expensive to construct and operate in Dublin’s climate zone compared to 1890
constructing buildings with both gas and electric utilities, especially when paired with solar photovoltaic (PV) installations. Coupled with the communitywide 100% carbon-free energy of Measure CF-1 in the CAP, new building electrification will result in homes and businesses that emit no GHGs. In addition, this amendment will meet the requirements of measure EE-1 of the CAP.
STRATEGIC PLAN INITIATIVE:
None
NOTICING REQUIREMENTS/PUBLIC OUTREACH:
In accordance with Government Code Sections 50022.3 and 6066, notice of the public hearing scheduled to take place on November 15, 2022 will be published on November 5, 2022 and November 12, 2022 in the East Bay Times. Attachments were made available for public review prior to this public hearing in accordance with Government Code Sections 50022.1 et. Seq. and 6066. The City Council Agenda was posted.
ATTACHMENTS:
1) Resolution Approving Amendments to the California Building Standards Code 2) Exhibit A to the Resolution - 2022 California Building Standards Code Findings 3) Ordinance Amending Sections of the California Building Standards Code 4) Exhibit A to the Ordinance - DMC Chapter 5.08 Fire Code 5) Exhibit B to the Ordinance – DMC Chapter 7.24 Floodplain Management Regulations 6) Exhibit C to the Ordinance - DMC Chapter 7.28 Building Administration Code 7) Exhibit D to the Ordinance - DMC Chapter 7.32 Building Code 8) Exhibit E to the Ordinance - DMC Chapter 7.34 Residential Code 9) Exhibit F to the Ordinance - DMC Chapter 7.36 Electrical Code 10) Exhibit G to the Ordinance - DMC Chapter 7.40 Plumbing Code 11) Exhibit H to the Ordinance - DMC Chapter 7.44 Mechanical Code 12) Exhibit I to the Ordinance - DMC Chapter 7.45 Swimming Pool and Spa Code 13) Exhibit J to the Ordinance - DMC Chapter 7.46 Existing Building Code 14) Exhibit K to the Ordinance - DMC Chapter 7.48 Building Maintenance Code 15) Exhibit L to the Ordinance - DMC Chapter 7.94 Green Building Code 1891
2022 California Building
Standards Code and the
Dublin Municipal Code
City Council
November 15, 2022
1892
2022 California Building Standards
Code
• CA Building Standards Commission adopts new
codes every 3 years
• These codes include the CA Fire, Building,
Residential, Electrical, Plumbing, Mechanical
and Green Codes
• Enforceable at the Local Level
• Approved by the Commission with an
enforcement date of January 1, 2023
1893
2022 California Building Standards
Code
• Floodplain Management Regulations, Existing
Building Code, International Swimming Pool
and Spa and Building Maintenance Codes.
• The City of Dublin may amend the State or
Model Code to account for Local: – Climatic, – Geological, or – Topographical Conditions • Historical Modifications by the City
1894
Fire Code
Chapter 5.08 DMC
• 2022 California Fire Code
• Pallet Storage requirements are not longer
necessary as these requirements have been
added to the code.
1895
Floodplain Management Regulations
7.24 DMC
• Updated to the latest standard
• Cumulative Substantial Improvement
• Dwelling Design
• Nonconversion agreements
• Repetitive Flood Damage Losses
• Determination of base flood elevation (BFE)
1896
Building Regulations Administration
Code Chapter 7.28 DMC
• Definitions Added
• New Codes – Swimming Pool & Spa and
Existing Building Code
• Electronic plan check required
• Live Load Posting
• Inspections, required added
1897
Building Code
Chapter 7.32 DMC
• 2022 CA Building Code
• Wall Bracing
• Floodplain updates – Definitions added – Violations procedures – Floodplain administrator 1898
Residential Code
Chapter 7.34
• 2022 California Residential Code
• Live / Work
• JADU meters
• Design Table updated
• Added Definitions for Substantially improved
and damaged
• Flood hazard areas design requirements
1899
Electrical, Plumbing, Mechanical,
Codes Chapters 7.36, 7.40, and 7.44
• 2022 California Electrical Code
• 2022 California Plumbing Code – Removal of section deleting fire sprinkler changes that conflicted with Fire Code
• 2022 Mechanical Code
1900
Swimming Pool and Spa Code
Chapter 7.45 DMC
• 2021 International Swimming Pool and Spa
Code – New Code
1901
Existing Building Code
Chapter 7.46 DMC
• 2022 California Existing Building Code – Previously used without modifications – New definitions for Substantially Improved and Substantially Damaged.
1902
Building Maintenance Code
Chapter 7.48 DMC
• 2021 International Property Maintenance Code
• Editorial updates only
1903
Green Building Code
Chapter 7.94 DMC
• Readopting Tier 2 Electric Vehicle (EV) Parking
Requirements.
• All Electric New Buildings and Qualifying
alteration projects.
• Exceptions – 1) Unable to comply with the Energy Code – 2) Commercial Kitchens for cooking equipment when approved by the Building Official.
1904
Recommendations
• Adopt the Resolution Approving Findings Regarding the need for Local Amendments to Provisions in the CA Building Standards Code, and • Waive the Second Reading and Adopt the Ordinance Repealing and Replacing Chapters 5.08 (Fire Code), 7.28 (Buildings Regulations Administration Code),
7.32 (Building Code), 7.34 (Residential Code), 7.36 (Electrical Code), 7.40 (Plumbing Code), 7.44 (Mechanical Code), 7.48 (Building Maintenance Code) and 7.94 (Green Building Code) of the Dublin Municipal Code, and Repealing Chapter7.24 (Flood Control) and Adopting Chapter 7.24 (Floodplain Management Regulations) and Adding Chapter 7.46 (Existing Building Code) to the Dublin Municipal code, in Order to Adopt by Reference and Amend Provisions of the 2022 Edition of the California Building Standards Code, Title 24, California Code of Regulations, and Adding Chapter 7.48 (Swimming Pool Spa Code) to the Dublin Municipal code in Order to Adopt by Reference and Amend Provision of the 2021 Edition of the International Swimming Pool and Spa Code. 1905