CITY of ESCONDIDO
Council Meeting Agenda
WEDNESDAY, AUGUST 20, 2025
3:30 PM - Closed Session (Parkview Conference Room)
5:00 PM - Regular Session
Escondido City Council Chambers, 201 North Broadway, Escondido, CA 92025
WELCOME TO YOUR CITY COUNCIL MEETING
We welcome your interest and involvement in the legislative process of Escondido. This agenda includes information about topics coming before the City Council and the action recommended by City staff.
MAYOR
Dane White
DEPUTY MAYOR
Consuelo Martinez (District 1)
COUNCILMEMBERS
Joe Garcia (District 2)
Christian Garcia (District 3)
Judy Fitzgerald (District 4)
CITY MANAGER
Sean McGlynn
CITY ATTORNEY
Michael McGuinness
CITY CLERK
Zack Beck
HOW TO WATCH
The City of Escondido provides three ways to watch a City Council meeting:
In Person On TV Online
201 N. Broadway Cox Cable Channel 19 and U-verse Channel 99 www.escondido.gov
HOW TO PARTICIPATE
The City of Escondido provides two ways to communicate with the City Council during a meeting:
In Person In Writing
Fill out Speaker Slip and Submit to City Clerk escondido-ca.municodemeetings.com
ASSISTANCE PROVIDED
If you need special assistance to participate in this meeting, please contact our ADA Coordinator at 760-839-4869.
Notification 48 hours prior to the meeting will enable to city to make reasonable arrangements to ensure accessibility. Listening devices are available for the hearing impaired – please see the City Clerk.
CLOSED SESSION
3:30 PM
CALL TO ORDER
1. Roll Call: Fitzgerald, C. Garcia, J. Garcia, Martinez, White
ORAL COMMUNICATIONS
In addition to speaking during particular agenda items, the public may address the Council on any item which is not on the agenda provided the item is within the subject matter jurisdiction of the City Council. State law prohibits the Council from discussing or taking action on such items, but the matter may be referred to the City Manager/staff or scheduled on a subsequent agenda. Speakers are limited to only one opportunity to address the Council under Oral Communications.
CLOSED SESSION
I. CONFERENCE WITH LEGAL COUNSEL – ANTICIPATED LITIGATION (Government Code § 54956.9(d)(2)) One Matter
II. CONFERENCE WITH LABOR NEGOTIATORS (Government Code § 54957.6) a. Agency Representative: Sean McGlynn, City Manager, or designee Employee Organization: Teamsters Local 986, Maintenance and Operations Bargaining Unit and Administrative / Clerical / Engineering Bargaining Unit b. Agency Representative: Sean McGlynn, City Manager, or designee Employee Organization: Escondido City Employees’ Association, Supervisory Bargaining Unit c. Agency Representatives: Sean McGlynn, City Manager, or designee Employee Organization: Escondido Police Association Non-Sworn Bargaining Unit d. Agency Representative: Sean McGlynn, City Manager, or designee Employee Organization: Police Officers' Association Sworn Personnel Bargaining Unit e. Agency Representative: Sean McGlynn, City Manager, or designee Employee Organization: Firefighters Association Safety and Non-Safety Bargaining Unit f. Agency Representative: Sean McGlynn, City Manager, or designee Employee Organization: Employee Organization: Police Management Association Bargaining Unit III. CONFERENCE WITH LEGAL COUNSEL – ANTICIPATED LITIGATION (Government Code § 54956.9(d)(2)) a. Flatiron Dragados West, LLC v. City of Escondido
ADJOURNMENT
REGULAR SESSION
5:00 PM Regular Session
MOMENT OF REFLECTION
City Council agendas allow an opportunity for a moment of silence and reflection at the beginning of the evening meeting. The City does not participate in the selection of speakers for this portion of the agenda, and does not endorse or sanction any remarks made by individuals during this time. If you wish to be recognized during this portion of the agenda, please notify the City Clerk in advance.
FLAG SALUTE
The City Council conducts the Pledge of Allegiance at the beginning of every City Council meeting.
CALL TO ORDER
Roll Call: Fitzgerald, C. Garcia, J. Garcia, Martinez, White
PRESENTATIONS
Interfaith CUP Informational Update
San Diego County Water Authority Board Member Rick Paul
CLOSED SESSION REPORT
ORAL COMMUNICATIONS
In addition to speaking during particular agenda items, the public may address the Council on any item which is not on the agenda provided the item is within the subject matter jurisdiction of the City Council. State law prohibits the Council from discussing or taking action on such items, but the matter may be referred to the City Manager/staff or scheduled on a subsequent agenda. Speakers are limited to only one opportunity to address the Council under Oral Communications.
CONSENT CALENDAR
Items on the Consent Calendar are not discussed individually and are approved in a single motion. However, Council members always have the option to have an item considered separately, either on their own request or at the request of staff or a member of the public.
1. AFFIDAVITS OF PUBLICATION, MAILING, AND POSTING (COUNCIL/RRB)
2. APPROVAL OF WARRANT REGISTER
Request the City Council approve the City Council and Housing Successor Agency warrants issued between August 04, 2025 to August 10, 2025.
Staff Recommendation: Approval (Finance Department: Christina Holmes, Director of Finance)
3. APPROVAL OF MINUTES: None
4. WAIVER OF READING OF ORDINANCES AND RESOLUTIONS
PUBLIC HEARING
5. IMPLEMENTATION AND FINANCING OF THE CITYWIDE ENERGY ROADMAP Request the City Council adopt Resolution No. 2025-107 authorizing the Mayor and/or Authorized Officers to execute, on behalf of the City: (1) the First Amendment to the Energy Services Agreement between the City and Climatec Energy Services (“Climatec”); (2) an Equipment Lease/Purchase Agreement with an initial principal value of $46,000,000 through Banc of America Public Capital Corp “(BAPCC”); (3) an Escrow and Account Control Agreement; and (4) such other agreements and documents as may be required to complete transactions to implement the Energy Roadmap.
Staff Recommendation: Approval (City Manager Department: Sean McGlynn, City Manager) Presenters: Christopher McKinney, Deputy City Manager; Christina Holmes, Finance Director; Ashley Lough, Climatec; and Tyler Girtman, Climatec
a) Resolution No. 2025-107
CURRENT BUSINESS
6. PUBLIC ART WORK PLAN: FISCAL YEAR 2024/2025 UPDATES AND FISCAL YEAR 2025/2026 PUBLIC ART
COMMISSION ANNUAL WORK PLAN
Request the City Council adopt Resolution No. 2025-110 approving and adopting the Fiscal Year 2025/2026 Public Art Commission Annual Work Plan.
Staff Recommendation: Approval (Economic Development Department: Jennifer Schoeneck, Director of Economic Development)
Presenter: Sandra Aguilar, Management Analyst
a) Resolution No. 2025-110
FUTURE AGENDA
7. FUTURE AGENDA
The purpose of this item is to identify issues presently known to staff or which members of the City Council wish to place on an upcoming City Council agenda. Council comment on these future agenda items is limited by California Government Code Section 54954.2 to clarifying questions, brief announcements, or requests for factual information in connection with an item when it is discussed.
Staff Recommendation: None (City Clerk's Office: Zack Beck)
COUNCILMEMBERS SUBCOMMITTEE REPORTS AND OTHER REPORTS
CITY MANAGER’S REPORT
The most current information from the City Manager regarding Economic Development, Capital Improvement Projects, Public Safety, and Community Development.
ORAL COMMUNICATIONS
In addition to speaking during particular agenda items, the public may address the Council on any item which is not on the agenda provided the item is within the subject matter jurisdiction of the City Council. State law prohibits the Council from discussing or taking action on such items, but the matter may be referred to the City Manager/staff or scheduled on a subsequent agenda. Speakers are limited to only one opportunity to address the Council under Oral Communications.
ADJOURNMENT
UPCOMING MEETING SCHEDULE
Wednesday, August 27, 2025 4:00 & 5:00 PM Closed Session, Regular Meeting, Council Chambers Wednesday, September 10, 2025 4:00 & 5:00 PM Closed Session, Regular Meeting, Council Chambers
SUCCESSOR AGENCY
Members of the Escondido City Council also sit as the Successor Agency to the Community Development Commission, Escondido Joint Powers Financing Authority, and the Mobilehome Rent Review Board.
Consent Item No. 1 August 20, 2025
A F F I D A V I T S
OF
I T E M
P O S T I N G –
Resolution of the City Council of the City of Escondido Approving Climatec Agreements, and Associated Equipment Lease/Purchase Agreements and Escrow and Account Control Agreements, Making Certain Findings Required Therefore, and Authorizing Certain Related Actions in Connection Therewith
8 Item1.
CITY OF ESCONDIDO
OFFICE OF THE CITY CLERK
201 NORTH BROADWAY
ESCONDIDO, CA 92025-2798
(760) 839-4617
NOTICE OF PUBLIC HEARING
NOTICE IS HEREBY GIVEN pursuant to Government Code Section 4217.12 and Section 4217.13, on WEDNESDAY, AUGUST 20, 2025 at 5 p.m., the Escondido City Council of the City of Escondido will hold a Public Hearing to consider the following:
Resolution of the City Council of the City of Escondido Approving Climatec Agreements, and Associated Equipment Lease/Purchase Agreements and Escrow and Account Control Agreements, Making Certain Findings Required Therefore, and Authorizing Certain Related Actions in Connection Therewith The City Council shall hold a public hearing presenting certain findings, taking public comment, and approving a Resolution adopting the findings and approving an amendment to an Energy Services Agreement (as amended, the “Energy Services Agreement”) and related Measurement and Verification Agreement, both with Climatec, LLC (“M&V Agreement” and, together with the Energy Services Agreement, the “Climatec Agreements”), in order to implement a Citywide Energy Roadmap Program, one or more Equipment Lease/Purchase Agreements with Banc of America Public Capital Corp (“BAPCC”) and/or an affiliate of BAPCC, and one or more related Escrow and Account Control Agreements, to finance certain energy conservation improvements to City facilities, all in accordance with California Government Code Section 4217.10 to 4217.18. The City Council findings shall demonstrate the cost of the Citywide Energy Roadmap Program implemented under the Climatec Agreements will be less than the anticipated marginal cost of thermal, electrical, or other energy that would have been consumed in the absence of those purchases and will also demonstrate that the funds for the repayment of the lease payments under the Equipment Lease/Purchase Agreement are projected to be available from funding that otherwise would have been used for purchase of electrical, thermal, or other energy required by the City in the absence of the financed improvements and equipment.
IF YOU CHALLENGE this item in court, you may be limited to raising only those issues you or someone else raised at the Public Hearing described in this notice, or in written correspondence delivered to the City Council, at or prior to the Public Hearing.
The City of Escondido recognizes its obligation to provide equal access to public services for those individuals with disabilities. Please contact the American Disabilities Act (A.D.A.) Coordinator (760) 839-4376 with any requests for reasonable accommodations, to include sign language interpreters, at least 24 hours prior to the meeting. The City of Escondido does not discriminate against any person with a handicapped status.
ALL INTERESTED PERSONS are invited to attend said Public Hearing to express their opinion in this matter. Said Public Hearing will be held in the Council Chambers, 201 N. Broadway, Escondido, California, 92025.
PUBLIC COMMENT: To submit comments in writing, please do so at the following link: https://escondidoca.municodemeetings.com/bc-citycouncil/webform/public-comment.
FOR ADDITIONAL INFORMATION, please contact Christopher McKinney, Deputy City Manager/Interim Director of Development Services (760) 839-4090.
ZACK BECK, City Clerk
City of Escondido
August 7, 2025
Published in THE ESCONDIDO TIMES ADVOCATE: 8/7/25
9 Item1.
STAFF REPORT
August 20, 2025
File Number 0400-40
SUBJECT
APPROVAL OF WARRANT REGISTER
DEPARTMENT
Finance
RECOMMENDATION
Approval for City Council and Housing Successor Agency warrants issued between August 04, 2025 to August 10, 2025
Staff Recommendation: Approval (Finance Department: Christina Holmes) ESSENTIAL SERVICE – Internal requirement per Municipal Code Section 10 COUNCIL PRIORITY –
FISCAL ANALYSIS
The total amount of the warrants for the following periods are as follows:
Dates 08/04/2025 to 08/10/2025
Total $3,917,486.46
Number of Warrants 231
BACKGROUND
The Escondido Municipal Code Section 10-49 states that warrants or checks may be issued and paid prior to audit by the City Council, provided the warrants or checks are certified and approved by the Director of Finance as conforming to the current budget. These warrants or checks must then be ratified and approved by the City Council at the next regular Council meeting. 10 Item2.
Consent Item No. 3 August 20, 2025
A P P R O V A L
O F
M I N U T E S
11 Item3.
12 Item4.
STAFF REPORT
August 20, 2025
File Number 0600-10; A-3564; A-3564-1-A; A-3564-1-B
SUBJECT
IMPLEMENTATION AND FINANCING OF THE CITYWIDE ENERGY ROADMAP
DEPARTMENT
City Manager
RECOMMENDATION
Request the City Council adopt Resolution No. 2025-107 authorizing the Mayor and/or Authorized Officers to execute, on behalf of the City: (1) the First Amendment to the Energy Services Agreement between the City and Climatec Energy Services (“Climatec”); (2) an Equipment Lease/Purchase Agreement with an initial principal value of $46,000,000 through Banc of America Public Capital Corp “(BAPCC”); (3) an Escrow and Account Control Agreement; and (4) such other agreements and documents as may be required to complete transactions to implement the Energy Roadmap.
Staff Recommendation: Approval (City Manager: Sean McGlynn, City Manager) Presenters: Christopher McKinney, Deputy City Manager; Christina Holmes, Finance Director; Ashley Lough, Climatec; and Tyler Girtman, Climatec
ESSENTIAL SERVICE – Yes, Keep City Clean for Public Health and Safety; Land Use/Development; Clean Water; Sewer; Public Works/Infrastructure; Maintenance of Parks facilities/Open Spaces COUNCIL PRIORITY – Eliminate Structural Deficit; Improve Public Safety; Increase Retention and Attraction of People and Businesses to Escondido; Encourage Housing Development
FISCAL ANALYSIS
The Energy Roadmap will reduce energy and power consumption, resulting in financial savings for the City benefitting the General Fund, the Water Fund, and the Wastewater Fund. The expected lifetime of the improvements is generally 15 to 20 years, with some solar projects having a projected 30-year lifetime.
Total projected lifecycle savings for all projects is $83.6 million including $70.4 million in operating budget savings and $13.2 million in capital budget savings. Savings projections assume that San Diego Gas and Electric (“SDG&E”) electricity rates will escalate 5 percent annually over the project lifetime.
The total implementation cost of all projects is approximately $55.9 million. Projects benefitting the General Fund account for $37.7 million of this total, Water Fund projects for $5.1 million, and Wastewater Fund project account for the remaining $13.1 million. Detailed information related to the scope of work 13 Item5.
can be found in Attachment “A”/Exhibit 1 of the First Amendment to Energy Services Agreement (Attachment “1”).
The City will fund program implementation with existing City funds on hand ($10 million) and via a taxexempt equipment lease-purchase agreement between the City, the lessee, and Banc of America Public Capital Corp (“BAPCC”), the lessor ($46 million).
BAPCC was selected for the lease-purchase agreement via a Request for Proposals (“RFP”) process initiated on May 14, 2025. Of the six responding banks, BAPCC was found to be the best value in terms of interest rate and flexibility of terms. The lease will be secured by the City’s obligation to pay annual lease payments, secured interest in the equipment to be installed by Climatec.
The lease-purchase agreement has a 20-year term at an interest rate of 4.022 percent. Annual principal and interest payments are $3,445,658 in most years, but the first payment of $1,722,828 – one-half the usual annual payment – is due on March 1, 2026. The total cost of the lease-purchase agreement, over the 20-year term, will be $68,913,159 in today’s dollars.
The $10 million city contribution will come from multiple sources within the Workers Compensation Fund and from funds in the Fiscal Year (“FY”) 2026 “Measure I” budgeted funds for the Climatec effort. In particular:
Workers Compensation – General Fund $5,525,480
Workers Compensation – Water Fund $1,180,360
Workers Compensation – Wastewater Fund $1,168,280
Measure I Funds $2,125,880
It should be noted that $4 million of Measure I Funds were budgeted in the FY 2026 budget. As mentioned above, about $1.7 million will be used for the first lease-purchase payment, with the bulk of the remaining funding used as part of the City’s up-front $10 million contribution. Concerning the use of Workers Compensation fund, Staff continue to analyze the fund and are confident that there are enough resources to cover Workers Compensation claims and use the remaining funds for other purposes. The current fund balance is approximately $16.6 million, and approximately $5.6 million will remain if the funds are used as recommended above.
Savings confirmed via the Monitoring and Verification (“M&V”) process for the General, Water, and Wastewater Funds – which are guaranteed by Climatec – will be used to cover the annual lease-purchase payments (~$3.4 million). Staff recommends budgeting Measure I funds to initially cover the full leasepurchase payments through 2035, allowing time for savings to accrue during construction and in the earlier years of useful life for new systems.
14 Item5.
Savings will grow on an annual basis as systems come online and will be measured & verified postconstruction. As confirmed savings increase, Measure I funding requirements will correspondingly decrease year-after-year until the annual payment can be paid through a combination of accrued and ongoing annual savings, expected to occur before 2036. This approach ensures the net cash flow stays cumulatively positive each year while transitioning from Measure I funding to project-generated savings as the primary funding source. Structuring the funding plan this way also ensures the program provides a positive net impact for the General Fund year after year.
PREVIOUS ACTION & REPORTS
In March 2024, the City awarded Request for Proposal (“RFP”) 23-04 to Climatec and authorized an Energy Services agreement to conduct citywide assessments and program development.
On January 29, 2025, the City Council received a preliminary report on the Citywide Energy Roadmap developed under the terms of the Energy Services Agreement with Climatec.
BACKGROUND
In March 2024, following an RFP process, the City awarded an Energy Services Agreement to Climatec to design and implement a Citywide Energy Roadmap, including comprehensive efficiency improvements and renewable energy measures. Currently, the City spends $12 million annually on electric and natural gas costs and has experienced a 40 percent increase in energy costs over the last five years. Aimed at reducing the rising costs and meeting state energy mandates, the Energy Roadmap will remedy failing and inefficient energy infrastructure and improve essential services.
On January 29, 2025, Climatec presented the preliminary scope of work and funding plan at a Council workshop. At its March 5, 2025 Visioning Meeting, the City Council directed staff to proceed with next steps for finalizing the Energy Roadmap in preparation for program implementation.
To-date, Climatec and staff have completed the following:
Analyzed electric and natural gas utility baseline data Developed an initial project feasibility assessment
Conducted engineering site assessments
Verified preliminary scope and funding options
Conducted detailed assessments of selected measures
Solicited financing proposals through the City’s municipal financial advisor Developed a final list of projects to be implemented
Selected funding options to align with preliminary construction schedule and savings proforma Reviewed agreement terms & technical scope details with involved City departments 15 Item5.
PROGRAM OVERVIEW
Summarized in the table below, the proposed Energy Roadmap program includes modernizations for comprehensive citywide energy, gas and water infrastructure, including throughout City buildings, parks, lakes facilities, the water treatment plant, and the wastewater treatment plant
NEXT STEPS
After conducting the Public Hearing in accordance with Government Code 4217 energy savings statute, the City Council will consider approval of the attached implementation and financing agreements for the Citywide Energy Roadmap. Pending City Council approval, financing is scheduled to close and an escrow fund will be created on August 28, 2025. Climatec will then kickoff construction mobilization in the coming weeks, with a construction phase anticipated to be 24-36 months.
During and after program construction, Climatec will monitor the savings and provide an annual report for City review. Climatec will also assist with obtaining eligible reimbursements from federal, state and local grants and incentive programs as systems come online (e.g. Inflation Reduction Act incentives). 16 Item5.
RESOLUTIONS
a) Resolution No. 2025-107
b) Resolution No. 2025-107—Exhibit “A”—Good Faith Estimates
ATTACHMENTS
a) Attachment “1”— First Amendment to Energy Services Agreement, including Attachment “A” and Exhibit 1
b) Attachment “2”— Escrow Account Control Agreement
c) Attachment “3”— Equipment Lease/Purchase Agreement
d) Attachment “4”— Budget Adjustment
17 Item5.
4930-7918-0629v4/022009-0059
RESOLUTION NO. 2025-107
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF
ESCONDIDO APPROVING CLIMATEC AGREEMENTS,
ASSOCIATED EQUIPMENT LEASE/PURCHASE AGREEMENTS
AND ESCROW AND ACCOUNT CONTROL AGREEMENTS,
MAKING CERTAIN FINDINGS REQUIRED THEREFORE, AND
AUTHORIZING CERTAIN RELATED ACTIONS IN CONNECTION
THEREWITH
WHEREAS, it is the policy of the State of California and the intent of the State Legislature to promote all feasible means of energy conservation, efficiency and renewable energy generation; and WHEREAS, the City of Escondido ("City") finds it to be in the best interests of the City to implement projects to promote energy efficiency and renewable energy to achieve utility budget cost reductions; and
WHEREAS, California Government Code Sections 4217.10 through 4217.18 authorize the City Council of the City (the “City Council”) to enter into one or more energy service contractsif the City Council finds that it is in the best interests of the City and that the anticipated cost to the City for thermal or electrical energy or conservation services under the contract will be less than the anticipated marginal cost to the City of thermal, electrical, or other energy that would have been consumed by the City in the absence of those purchases; and
WHEREAS, the City Council and City staff reviewed the qualifications and pricing submitted by Climatec, LLC (“Climatec”) in May 2023 under RFP No. 23-04 for the Citywide Energy Roadmap project and found Climatec’s qualifications to be bona fide and adequate; and WHEREAS, Climatec collaborated with City staff to assess the feasibility of various energy conservation measures to reduce the City’s energy consumption and cost and coauthored a design/build scope of work (“Program”) to meet the City’s needs; and 18 Item5.
2 4930-7918-0629v4/022009-0059
WHEREAS, in order to implement the Program, the City and Climatec desire to enter into a First Amendment to Energy Services Agreement (“ESA Amendment”), which amends that certain Energy Services Agreement, dated as of March 14, 2024, between the City and Climatec (the “Original Energy Services Agreement” and, together with the ESA Amendment, the “Energy Services Agreement”), for Climatec to provide design/build implementation of the energy conservation measures for the price stated therein, and a Measurement & Verification Agreement (“M&V Agreement” and, together with the Energy Services Agreement, the “Climatec Agreements”) for Climatec to provide annual reporting and a savings performance guarantee, forms of which have been presented to the City Council at the meeting at which this Resolution has been adopted; and
WHEREAS, Climatec’s analysis demonstrates that the cost for energy conservation services provided under the Climatec Agreements is less than the anticipated marginal cost to the City of thermal, electrical or other energy that would have been consumed by the City in the absence of such services under the Climatec Agreements; and
WHEREAS, the City has determined that it is necessary and desirable to finance the acquisition of certain solar and energy efficiency equipment for the benefit of the City (collectively, the “Project”); and WHEREAS, California Government Code Sections 4217.10 through 4217.18 authorize the City Council to enter into one or more facility financing contracts if the City Council finds that it is in the best interests of the City and that funds for the repayment of the financing or the cost of design, construction, and operation of the improvements/equipment (or both), are projected to be available from revenues resulting from sales of electricity or thermal energy from the improvements/equipment or from funding that otherwise would have been used for purchase of electrical, thermal, or other energy required by the City in the absence of the improvements/equipment (or both); and 19 Item5.
3 4930-7918-0629v4/022009-0059
WHEREAS, in order to accomplish the financing of the Project, the City and Banc of America Public Capital Corp (“BAPCC”) and/or an affiliate of BAPCC desire to enter into one or more Equipment Lease/Purchase Agreements, by and between the City and BAPCC or an affiliate of BAPCC (collectively, the “Lease”), a form of which has been presented to the City Council at the meeting at which this Resolution has been adopted; and
WHEREAS, pursuant to the Lease, the City will grant a security interest in certain equipment owned or to be acquired by the City (the “Equipment”) to BAPCC and/or an affiliate of BAPCC in consideration for BAPCC and/or an affiliate of BAPCC financing such Equipment in an amount not to exceed $46,000,000, and the City will lease the Equipment from BAPCC and/or an affiliate of BAPCC and pay certain rental payments in connection therewith; and WHEREAS, Climatec’s analysisindicates that funds for the repayment of the lease payments under the Lease are projected to be available from funding that otherwise would have been used for purchase of electrical, thermal or other energy required by the City in the absence of the Equipment; WHEREAS, a noticed public hearing was held by the City Council to consider the Climatec Agreements (which will implement the Program), the Lease, and Escrow Agreement (hereinafter defined) and the transaction authorized by this Resolution in accordance with California Government Code Section 4217.10, et seq., specifically Section 4217.12 and Section 4217.13.
NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Escondido, California as follows:
1. The City Council does hereby find and declare that the above recitals are true and correct, and adopted by this reference as findings of the City Council. 20 Item5.
4 4930-7918-0629v4/022009-0059
2. The City Council determines that the Climatec Agreements which will implement the Program authorized by this Resolution are in the best interest of the City and its residents and further finds that the cost for energy conservation services provided under the Climatec Agreements is less than the anticipated marginal cost to the City of thermal, electrical or other energy that would have been consumed by the City in the absence of such services under the Climatec Agreements.
3. The City Council determines that the Lease and Escrow Agreement (hereinafter defined) and the transaction authorized by this Resolution are in the best interest of the City and its residents and further finds that the funds for the repayment of the lease payments under the Lease are projected to be available from funding that otherwise would have been used for purchase of electrical, thermal or other energy required by the City in the absence of the Equipment.
4. The forms of the Climatec Agreements presented to this meeting and on file with the City Clerk, are hereby approved. Each of the Mayor of the City, or such member of the City Council as the Mayor may designate, the City Manager of the City, the Deputy City Manager of the City, the Director of Finance of the City, and their authorized designees (the “Authorized Officers”) is hereby authorized for and in the name of the City to execute the Climatec Agreements in substantially the forms on file with the City Clerk, with such additions thereto and changes therein as are recommended or approved by Stradling Yocca Carlson & Rauth LLP, as Special Counsel (“Special Counsel”), the City Attorney and the officers executing the same. Approval of such changes shall be conclusively evidenced by the execution and delivery of the Climatec Agreements by such Authorized Officers. Each of the Authorized Officers is hereby authorized to execute, acknowledge and deliver any and all documents required to consummate the transactions contemplated by the Climatec Agreements.
5. The form of the Lease presented to this meeting and on file with the City Clerk, is hereby approved; provided that the maximum principal amount of all rental payments pursuant to the Lease shall 21 Item5.
5 4930-7918-0629v4/022009-0059
not exceed $46,000,000 and the interest rate on the principal component of the rental payments the interest on which is to be excluded from gross income for federal and State income tax purpose shall not exceed 6.00% (except in the case of any increase due to a late payment, a default or an event of taxability) and the interest rate on the principal component of the rental payments the interest on which is not excluded from gross income for federal income tax purposes shall not exceed 7.00% (except in the case of any increase due to a late payment or a default). Each of the Authorized Officers is hereby authorized for and in the name of the City to execute one or more Leases in substantially the form on file with the City Clerk, with such additions thereto and changes therein as are recommended or approved by Special Counsel, the City Attorney and the officers executing the same. Approval of such changes shall be conclusively evidenced by the execution and delivery of the Leases by such Authorized Officers. Each of the Authorized Officers is hereby authorized to execute, acknowledge and deliver any and all documents required to consummate the transactions contemplated by the Leases.
6. The form of one or more Escrow and Account Control Agreements (collectively, the “Escrow Agreement”) by and among BAPCC (or any affiliate of BAPCC), the City and UMB Bank, National Association, as escrow agent, presented to this meeting and on file with the City Clerk, is hereby approved.
Each of the Authorized Officers is hereby authorized for and in the name of the City to execute one or more Escrow Agreements in substantially the form on file with the City Clerk, with such additions thereto and changes therein as are recommended or approved by Special Counsel, the City Attorney and the officers executing the same. Approval of such changes shall be conclusively evidenced by the execution and delivery of the Escrow Agreements by such Authorized Officers. Each of the Authorized Officers is hereby authorized to execute, acknowledge and deliver any and all documents required to consummate the transactions contemplated by the Escrow Agreements. 22 Item5.
6 4930-7918-0629v4/022009-0059
7. Each of the Authorized Officers is hereby authorized, jointly and severally, to do any and all things and to execute and deliver any and all documents which they may deem necessary and advisable in order to consummate the entry into of the Climatec Agreements, Leases and the Escrow Agreements and otherwise effectuate the purposes of this Resolution.
8. The City Council acknowledges that the good faith estimates required by Section 5821.1 of the California Government Code are attached hereto as Exhibit A and are available to the public at the meeting at which this Resolution is approved.
9. All actions heretofore taken by the Authorized Officers with respect to the Climatec Agreements, Lease and Escrow Agreement, or in connection with or related to any of the agreements or documents referenced herein, are hereby approved, confirmed and ratified.
10. This Resolution shall take effect from and after the date of approval and adoption hereof. 23 Item5.
Resolution No. 2025-107
Exhibit “A”
4930-7918-0629v4/022009-0059
EXHIBIT A
GOOD FAITH ESTIMATES
The good faith estimates set forth herein are provided with respect to the Lease in accordance with Section 5852.1 of the California Government Code. Such good faith estimates have been provided to the City by CSG Advisors Incorporated, the City’s municipal advisor (the “Municipal Advisor”).
Principal Amount. The Municipal Advisor has informed the City that, based on the City’s financing plan, its good faith estimate of the aggregate principal amount of the Lease to be issued and sold is $46,000,000 (the “Estimated Principal Amount”).
True Interest Cost of the Lease. The Municipal Advisor has informed the City that, assuming that the Estimated Principal Amount of the Lease is issued and sold, and based on market interest rates prevailing at the time of preparation of such estimate, its good faith estimate of the true interest cost of the Lease, which means the rate necessary to discount the amounts payable on the respective principal and interest payment dates to the purchase price received for the Lease, is 4.274%.
Finance Charge of the Lease. The Municipal Advisor has informed the City that, assuming that the Estimated Principal Amount of the Lease is issued and sold, and based on market interest rates prevailing at the time of preparation of such estimate, its good faith estimate of the finance charge for the Lease, which means the sum of all fees and charges paid to third parties (or costs associated with the Lease), is $100,000.
Amount of Proceeds to be Received. The Municipal Advisor has informed the City that, assuming that the Estimated Principal Amount of the Lease is issued and sold, and based on market interest rates prevailing at the time of preparation of such estimate, its good faith estimate of the amount of proceeds expected to be received by the City for sale of the Lease, less the finance charge of the Lease, as estimated above, and any reserves or capitalized interest paid or funded with proceeds of the Lease, is $45,900,000.
Total Payment Amount. The Municipal Advisor has informed the City that, assuming that the Estimated Principal Amount of the Lease is sold, and based on the interest rate of the Lease, its good faith estimate of the total payment amount, which means the sum total of all payments the City will make to pay the Lease, plus the finance charge for the Lease, as described above, not paid with the proceeds of the Lease, calculated to the final maturity of the Lease, is $68,913,153, which excludes any reserves or capitalized interest funded or paid with proceeds of the Lease (which may offset such total payment amount).
The foregoing estimates constitute good faith estimates only and are based on information available at the time of preparation of such estimates. The actual principal amount of the Lease issued and sold, the true interest cost thereof, the finance charges thereof, the amount of proceeds received therefrom and total payment amount with respect thereto may differ from such good faith estimates due to (a) the actual date of the sale of the Lease being different than the date assumed for purposes of such estimates, (b) the actual principal amount of Lease issued and sold being different from the Estimated Principal Amount, (c) the actual amortization of the Lease being different than the amortization assumed for purposes of such estimates, (d) the actual market interest rates at the time of sale of the Lease being different than those estimated for purposes of such estimates, (e) other market conditions, or (f) alterations in the City’s financing plan, or a combination of such factors. The actual date of the Lease and the actual principal amount of Lease issued and sold will be determined by the City based on the timing of the need for proceeds of the Lease and other factors.
24 Item5.
Attachment “1”
First Amendment - 1 - CAO: 04/23/2024
To Public Services Agreement
CITY OF ESCONDIDO
FIRST AMENDMENT TO ENERGY SERVICES AGREEMENT
This First Amendment to Energy Services Agreement (“First Amendment”) is made and entered into as of the last signature date set forth below (“Effective Date”), Between: CITY OF ESCONDIDO
a California municipal corporation
201 N. Broadway
Escondido, CA 92025
Attn: Christopher McKinney, Deputy City Manager
760-839-4090
("CITY")
And: CLIMATEC, LLC
an Arizona limited liability company
2851 West Kathleen Road Phoenix, AZ 85053
Attn: Ashley Lough
602-400-2859
(referred to herein as “Contractor” and “ESCO")
(The CITY and ESCO each may be referred to herein as a “Party” and collectively as the “Parties.”)
WHEREAS, the Parties entered into that certain Energy Services Agreement dated March 14, 2024 (“Agreement”), wherein CITY retained ESCO to provide the development and implementation plan of a Citywide Energy Roadmap consistent with the provisions of California Government Code sections 4217.10 – 4217.18 that will provide sustained energy efficiencies and energy cost savings at project site locations (“Project”), as more specifically described in the Agreement; WHEREAS, the Parties desire to amend the Agreement to include additional services for Phase 3 of the Project (Implementation/Construction) as described in “Attachment A” to this First Amendment, which is attached hereto and incorporated herein by this reference.
NOW, THEREFORE, in consideration of the mutual covenants, promises, terms, and conditions set forth herein, and the mutual benefits derived therefrom, the Parties hereby agree as follows:
A. The ESCO will furnish all of the Services described in “Attachment A” to this First Amendment.
B. The CITY will compensate the ESCO an additional amount not to exceed the sum of $55,889,697, pursuant to the conditions contained in “Attachment A” to this First Amendment. 25 Item5.
Attachment “1”
First Amendment - 2 - CAO: 04/23/2024
To Public Services Agreement
C. INSTALLATION. Contractor shall provide City with an Energy Infrastructure Modernization Program, as identified in Attachment A Exhibit 1 and incorporated herein by reference at the total fixed price of $55,889,697 including required taxes and performance bond.
Contractor is responsible for the design, engineering, permits, fees, approvals, project management, installation, startup, training, checkout, warranty, and insurance specifically associated with the Work to be performed. Contractor is not responsible for any equipment, systems, controls, comfort problems, balancing, duct cleaning, existing deficient conditions, etc. not specifically included in this Agreement. Contractor will provide submittals and engineered drawings (if required), for City’s technical review and written approval, prior to initiating construction. All construction and associated cleanup shall be performed and scheduled to minimize any disruption with any ongoing City activities. Contractor shall keep the Site(s) in order and shall maintain a reasonably clean condition and provide the City with safe and proper access to all Work at all times. Contractor requires all underground conduits between buildings to be clear of obstruction, of sufficient size to accommodate new wire and cable, and easily accessible.
The City is responsible for Ethernet drops at each location for Energy Management System communication.
D. SCOPE OF WORK. The Scope of Work is defined in Attachment “A” of this Amendment. Once this First Amendment is executed by the City and Contractor, Contractor may not revise the First Amendment (including the Scope of Work) in any way except by mutual written agreement with the City.
Contractor shall keep the Site(s) in order when Work is being performed and shall maintain the Site(s) in a reasonably clean condition. The City shall always have access to the Work. Contractor will maintain safety in the performance of the Work and shall erect and maintain, as required by conditions and progress of Work, all necessary safeguards including necessary permits, signs, barriers, lights, and security persons for protection of workers and the public and shall post danger signs warning against hazards created by the Work.
This Agreement is based upon the use of straight time labor only unless stated otherwise in this Agreement. Contractor agrees to keep the job site clean of debris arising out of its own operations. Except as provided herein, City shall not back charge Contractor for any cost or expenses without Contractors written consent. Unless specifically noted in Attachment A or services undertaken by Contractor under this Agreement, Contractor’s obligations under this Agreement expressly exclude any work or service of any nature associated or connected with the identification, abatement, clean up, control, removal or disposal of environment hazards or dangerous substances, to include but not to be limited to asbestos, PCBs, or mold discovered in or on the premises and is limited to the Scope of Work that includes water, wastewater, and/or roofing. However, if any hazardous materials are found within the Work involving water, wastewater and/or roofing, the City has the option to have a 3rd party remediate the hazardous materials or under a separate agreement the Contractor provide remediation at the job site(s).
Any language or provision of the Agreement elsewhere contained which may authorize or empower the City to change, modify or alter the scope of work or services to be performed by Contractor shall not operate to compel Contractor to perform any work relating to hazards without Contractor’s express written consent.
E. SOLAR INSTALLATION. The Scope of Work excludes correction of concealed conditions that could not have been ascertained by general visual inspection. The Work excludes correction of any existing or previous violations of laws, codes or utility requirements and errors and omissions of the City or other contractors not communicated to Contractor. City will provide all discretionary 26 Item5.
Attachment “1”
First Amendment - 3 - CAO: 04/23/2024
To Public Services Agreement
permits (permits requiring the discretion of the issuer) required in time to execute the Work within the agreed upon schedule. Contractor will provide all non-discretionary, ministerial (permits not requiring thought and discretion of the issuer) permits required for the provision of the solar installation. City agrees to promptly execute and return provided Preliminary Interconnection Documentation (initial or preliminary paperwork or documentation required by the Utility for interconnection of the system to be executed by the system owner), Preliminary Rebate Documentation (documentation comprising the initial or preliminary paperwork required by the administrator of the Rebate or the Rebate to be reserved) (if applicable), and Site Owner Consent Documentation (agreement from the site owner to install system on the real property identified in the proposal) (if applicable). Attachment D of Tab C located within Exhibit 1 which is referenced in Attachment A of this Amendment, will include commercially reasonable efforts to promptly obtain the PTO (Permission to Operate) from City’s utility. The monitoring equipment provider will provide monitoring hosting services for the first five years of operation. City warrants that they hold title to the installation site and agree to the solar installation on that site.
Terms applicable to the solar scope are as follows:
a. Interconnection Agreement – means an agreement between the City and a particular utility involved for interconnection of the solar output to the electrical grid. b. Interconnection Equipment – all equipment (including wiring and conduit and metering for net metering) on the City side of the main service meter to enable proper interconnection of the solar system to the grid.
Design – Subject to Council approving Program Implementation, Contractor will complete final elements of design and engineering such as land surveys, geotechnical studies and preparation of design documents and drawings required to prepare submittal packages, obtain permits and procure equipment. Contractor shall prepare the design submittals (prepared by qualified individuals). The submittal shall be submitted to City for approval. City shall provide approvals within fifteen business days from receipt. The Contractor shall not proceed with work until approval is granted by the City.
Unforeseen Site Conditions – Within 10 business days of discovery, Contractor will notify City in writing of (a) subsurface or latent physical conditions at the site differing materially from those described in any contract or City documentation that will affect the price of delivery of the Work.
Should such conditions arise, the City will have several options to consider, including identifying an alternative location for the affected scope (e.g. moving Solar PV array) or removing the scope.
F. INVOICING & PAYMENTS. Contractor may invoice the City for any equipment and/or materials installed at a job site. City shall have no obligation to pay for equipment or supplies unless and until unconditional releases from all suppliers of the same have been provided to the City. Except for amounts in dispute, the City agrees to pay Contractor amounts invoiced upon receipt of invoice for completion of Work. Except for amounts in dispute, City shall retain 5% from all payments as retention in accordance with Public Contract Code Section 7107. Final Payment, including retention withheld, will be due in accordance with Public Contract Code 7107, or as otherwise provided by law. If Contractor’s undisputed invoice is not paid within 30 days of its receipt, it is delinquent and Contractor may add one percent (1%) per month interest onto delinquent amounts.
G. INDEPENDENT CONTRACT. It is agreed between City and Contractor that Contractor shall perform the Work as an independent contractor. Contractor may use subcontractors to perform work hereunder, provided Contractor shall fully pay said subcontractors and in all instances 27 Item5.
Attachment “1”
First Amendment - 4 - CAO: 04/23/2024
To Public Services Agreement
remain fully responsible for (a) the proper completion of this Agreement and (b) supervising such subcontractor’s work and the quality of their workmanship.
H. SUBCONTRACTORS. Contractor shall submit to the City in writing a list of any subcontractors engaged by the Contractor for any Work for the City’s prior written approval, not to be unreasonably withheld. Contractor agrees to bind every subcontractor by the terms of this Contract, including, without limitation, indemnification, insurance, business license and warranty requirements. Contractor shall be fully responsible to City for the Work of its subcontractors and persons directly or indirectly employed by them. The Contract shall not create any contractual relationship between any subcontractor and City.
Contractor and all subcontractors performing the work shall not employ any person who is unfit or unskilled in assigned Work. Contractor and/or subcontractor shall dismiss any person whom City deems incompetent or unfit.
I. MATERIALS. All materials shall be new, in compliance with all applicable laws and codes, and shall be covered by a manufacturer’s warranty, if appropriate. If the materials or equipment included in this Agreement become temporarily unavailable, the Contractor shall immediately notify the City in writing of the unavailability and the time for performance of the Work shall be extended to the extent thereof with the City’s written consent. In the case of permanent unavailability, Contractor shall immediately notify the City in writing of the unavailability and shall only be excused from furnishing said materials with the City’s written consent.
J. OWNERSHIP. Title to the Equipment/Materials (or portion thereof) shall pass free and clear to the City from the Contractor upon final payment by the City for the Equipment/Materials, Work or Services corresponding to such Equipment (or portion thereof).
K. COMPLETION. The Work shall be considered completed upon written approval by the City, provided that the City’s approval shall not be unreasonably withheld. The nature of the Work consists of multiple projects and/or sites, as noted in Attachment ”A” Scope of Work. Once work on a project or a site is deemed by the Contractor to be substantially complete (that is available for beneficial use by the City with the scope of work for that site or project functioning as required) and concurrence is provided by the City, except for minor items (a punch list), Contractor will provide a written Notice of Substantial Completion for that site or project to the City. Final Completion, as previously noted, will occur once the entire scope of work is complete for all sites and projects.
L. CORRECTION OF ERRORS. Contractor shall perform, at its own cost, without reimbursement from the City, any work necessary to correct errors or omissions caused by Contractor’s failure to comply with the standard of care required herein.
M. WARRANTY. Contractor warrants that the equipment and systems provided under this Agreement shall be free from defects in material and workmanship arising from normal usage for a period of one year from the date of beneficial uses. Within the warranty period, if City provides written notice to Contractor of any such defects within 30 days after the appearance or discovery of such defect, Contractor shall, at its option, repair or replace the defective equipment and return said equipment to City. These warranties do not extend to any equipment which has been repaired by others, abused, altered, or misused, or which has not been properly and reasonably maintained. All transferable manufacturer warranties associated with the equipment will be transferred to the City. These warranties are in lieu of all other warranties, expressed or implied, including but not limited to those of merchantability and fitness for a specific purpose. 28 Item5.
Attachment “1”
First Amendment - 5 - CAO: 04/23/2024
To Public Services Agreement
N. LIABILITY. Neither party shall be liable to the other for any special, indirect, or consequential damages arising in any manner from the equipment, material, or systems furnished or the work performed pursuant to this Agreement.
O. TERMINATION. Term of this agreement shall commence as of the Effective Date and, unless sooner terminated, shall expire (with the exception of Warranty obligations) forty-five days after all Work is complete and accepted by the City. The City may terminate this agreement for any reason at any time by providing Contractor not less than 10 business days prior, written notice.
Provided Contractor is not then in breach, Contractor will be paid for all documented work satisfactorily performed and for all equipment and materials theretofore purchased that Contractors documents cannot be returned for credit, as of the date of the notice of termination.
P. DELAYS. Contractor shall not be liable for any delay in the performance of the Work resulting from or attributed to acts of circumstance beyond Contractor’s control, including acts of God, riots, labor disputes, conditions of the premises, or acts or omissions of the City. If City delays project for greater than 60 calendar days, Contractor can recover any cost inflation on un-billed materials that were either stored or yet to be purchased.
Q. REBATES, UTILITY INCENTIVES. Unless otherwise stated in the Agreement, or cash flow analysis, any and all rebates, incentives that are earned through the course of this project from public or private utilities, municipalities, development City’s or state funding, with the exception of lighting rebates, are 100% the property of the City or their designee. Lighting rebates are 100% the property of Contractor and are used to reduce the project cost to the City. The paperwork, inspections and verification required to collect these monies (except for lighting rebates) are the sole responsibility of the City.
R. LABOR CODE REQUIREMENTS: If the Contract Price is more than $1,000, and the Work is a “public works” as defined in the Labor Code including, without limitation, §§ 1720 - 1720.6 and 1771 then this subsection applies. City hereby provides notice of the requirements described in Labor Code § 1771.1(a) that a contractor or subcontractor shall not be qualified to bid on, be listed in a bid proposal, or engage in the performance of any contract for public work, unless currently registered and qualified to perform public work pursuant to Labor Code § 1725.5.
Contractor acknowledges that all or a portion of the Services under this Contract are a public work, and that it and its subcontractors have complied with Labor Code § 1725.5, including, without limitation, the registration requirements thereof. Contractor shall post all required job site notices and shall comply with all applicable requirements prescribed thereby, including but not limited to Labor Code § 1771.4. Contractor shall comply with all applicable provisions of Chapter 1 of Part 7 of Division 2 of the Labor Code (Section 1720 et seq.) and California Code of Regulations, Title 8, Chapter 8, Subchapters 3-6 (Section 16000 et seq.) Willful failure to comply may result in penalties, including loss of the right to bid on or receive public works contracts.
Copies of the prevailing rate of per diem wages are on file with the City and available on the DIR website. Monitoring and enforcement of the prevailing wage laws and related requirements will be performed by the Labor Commissioner/ Department of Labor Standards Enforcement (DLSE).
The Contractor and all subcontractors shall furnish certified payroll records as required pursuant Labor Code § 1776 directly to the Labor Commissioner in accordance with Labor Code § 1771.4 on at least on a monthly basis (or more frequently if required by the City or the Labor Commissioner) and in a format prescribed by the Labor Commissioner. The Contractor and all Subcontractors shall comply with the provisions of California Labor Code including, but not limited to sections 1777.5, 1777.6, and 1777.7 concerning the employment of apprentices. The Contractor and all subcontractors shall comply with the requirements of said sections, including applicable portions of all subsequent amendments in the employment of apprentices; however, the Contractor shall have full responsibility for compliance with said Labor Code sections, for all 29 Item5.
Attachment “1”
First Amendment - 6 - CAO: 04/23/2024
To Public Services Agreement
apprenticeable occupations, regardless of any other contractual or employment relationships alleged to exist.
S. INFLATION REDUCTION ACT.
1. Contractor acknowledges that the Buyer intends that the Facility will satisfy the requirements for a refundable tax credit under IRC §§6417 and 48E.
2. Contractor will meet the prevailing wage and apprenticeship requirements established in IRC §48E(d)(3) and (d)(4), and as further described in Reg. §§1.48E–3, 1.45–6 through
1.45–8, 1.45–12, and other applicable IRS guidance.
3. All laborers and mechanics employed by Contractor in connection with the construction, the alteration or repair of the Facility will be paid wages at rates not less than the prevailing rates for construction, alteration, or repair of a similar character in the locality in which the Facility is located as most recently determined by the Secretary of Labor, in accordance with subchapter IV of chapter 31 of title 40, United States Code (Davis-Bacon Act).
Contractor will employ “qualified apprentices” enrolled in a registered apprenticeship program for at least 15% of the total construction labor hours any of its mechanics or labors completed work toward improving the Facility, subject to meeting any apprentice-to-journey worker ratios, as described further in Treas. Reg 1.145-8. Construction is defined as onsite physical work performed on City premises.
4. Contractor will meet the apprenticeship “Participation Requirement”, which requires that each (sub)contractor that employs four or more laborers or mechanics (various trade personnel) to perform construction, alteration, or repair work with respect to the construction of the Facility must hire at least one qualified apprentice throughout the project, and the apprenticeship “Ratio Requirement”, which states that, on a daily basis, each (sub)contractor must not exceed the required ratio (as governed by the individual apprentice program) of apprentices-to-journeyworkers.
5. Contractor will maintain books and records sufficient to document that it satisfied the prevailing wage and apprenticeship requirements (and made such records available to City), as provided in Treas. Reg. §1.45-12, including payroll records for each laborer and mechanic including but not limited to, any agreements entered into with registered apprenticeship programs, identifying information, location and type of facility, labor classification, hourly rate, labor hours worked, wages paid for each pay period, and amount and timing of any correction payment.
6. Contractor shall “begin construction” of the Project on or before December 31, 2025. “Beginning construction” is defined in IRS Notice 2018-59 as starting physical work of a significant nature (“Physical Work Test”) or incurring 5% or more of the total cost of energy property (“5% Safe Harbor”); provided, Contractor shall comply with any subsequently released applicable guidance regarding “Beginning Construction”.
7. Contractor shall meet the Physical Work Test, as described in IRS Notice 2018-59 and any successors thereto, to begin construction on the Project on or before December 31, 2025.
As described in Notice 2018-59, preliminary activities such as planning, design, site exploration, or surveys do not qualify as physical work of a significant nature.
8. Per Continuity Safe Harbor provisions of the IRS, the project must be placed into service by the end of a calendar year that is no more than four calendar years after the calendar year during which construction of the Project began.
T. DISPUTES. The Dispute Resolution Provisions require that each Claim be in writing, served on the other party, describing specific details of the dispute relating to changes in Work or claim for additional compensation, within seven calendar days of the occurrence of the condition. This notice must be provided via certified mail. For a reasonable period commencing on the day written notice of dispute was provided, but not to exceed 30 calendar days, the parties shall in 30 Item5.
Attachment “1”
First Amendment - 7 - CAO: 04/23/2024
To Public Services Agreement
good faith attempt to resolve the dispute. If the parties are unable to resolve the Dispute during this period, the parties shall proceed as required by Public Contract Code Sections 9204 and 20104, et seq. Effective January 1, 1991, Section 20104 et seq., of the Public Contract Code prescribes a process utilizing informal conferences, non-binding judicial supervised mediation, and judicial arbitration to resolve disputes on construction claims of $375,000 or less. Effective January 1, 2017, Section 9204 of the Public Contract Code prescribes a process for negotiation and mediation to resolve disputes on construction claims. The intent of this Section is to require that the parties hereto shall proceed to resolve any disputes in accordance with the procedures set forth in Sections 9204 and 20104.
In addition to any and all contract requirements pertaining to notices of and requests for compensation or payment for extra work, disputed work, claims and/or changed conditions, Contractor must comply with the claim procedures set forth in Government Code section 900, et seq., prior to filing any lawsuit against the Purchaser.
U. CHANGE ORDER (Mid-Performance Amendments). Contractor and the City recognize that:
1. City may desire a mid-job change in the specifications or scope that would add time and cost to the specified work or inconvenience Contractor.
2. Other provisions of the Agreement may be difficult to carry out because of unforeseen events, such as material shortage or labor strikes.
If these or other events beyond the control of the parties reasonably require adjustments to this Agreement, the parties shall make a good faith attempt to agree on all necessary particulars.
Such agreements shall be put in writing, signed by the parties, and added to this Agreement.
Failure to reach agreement shall be deemed a dispute to be resolved as agreed in section 20 of this Agreement.
U. PAYMENT & PERFORMANCE BONDS: Contractor shall not commence Work until it has provided to City, in the form provided by the City, a Payment (Labor and Material) Bond and a Performance Bond, each in an amount equivalent to 100% of the Contract Price issued by an admitted surety as defined in Code of Civil Procedure § 995.120.
V. OCCUPANCY: City may occupy buildings before Contract completion and occupancy shall not constitute acceptance of any Work, nor shall occupancy extend the Contract completion date.
All other terms of the Agreement not referenced in this First Amendment shall remain unchanged and in full force and effect. In the event of a conflict between a provision of the Agreement and this First Amendment, this First Amendment shall prevail.
This First Amendment and the Agreement, together with any attachments or other documents described or incorporated therein, if any, constitute the entire agreement and understanding of the Parties, and there are no other terms or conditions, written or oral, controlling this matter.
This First Amendment may be executed on separate counterparts that, upon completion, may be assembled into and shall be construed as one document. Delivery of an executed signature page of this First Amendment by electronic means, including an attachment to an email, shall be effective as delivery of an executed original.
31 Item5.
Attachment “1”
First Amendment - 8 - CAO: 04/23/2024
To Public Services Agreement
Unless a different date is provided in this First Amendment, the effective date of this First Amendment shall be the latest date of execution set forth by the names of the signatories below IN WITNESS WHEREOF, this First Amendment is executed by the Parties or their duly authorized representatives as of the Effective Date:
CITY OF ESCONDIDO
Date: __________________ ____________________________________ Dane White, Mayor
CLIMATEC, LLC
Date: __________________ ___________________________________ Signature
___________________________________
Name & Title (please print)
APPROVED AS TO FORM:
OFFICE OF THE CITY ATTORNEY
MICHAEL R. MCGUINNESS, CITY ATTORNEY
BY: __________________________
DATE: _________________
THE CITY OF ESCONDIDO DOES NOT DISCRIMINATE AGAINST QUALIFIED PERSONS WITH DISABILITIES. 32 Item5.
Attachment “1”
First Amendment - 9 - CAO: 04/23/2024
To Public Services Agreement
ATTACHMENT “A”
Scope of Work
A. General
Climatec, LLC, an Arizona limited liability company (“ESCO”) will provide the City of Escondido, a California municipal corporation (“City”) with implementation and construction services for the City’s Citywide Energy Roadmap Project (“Project”).
B. Location
ESCO will provide services at multiple City locations as described in Exhibit 1, to this Scope of Work, which is attached hereto and incorporated herein by this reference. In the event of a conflict between Exhibit 1 and this Agreement, the terms of the Agreement shall prevail.
C. Services
Implementation and construction services provided under this First Amendment shall be in accordance with Exhibit 1.
D. Scheduling
ESCO to schedule specific dates of work in advance by contacting Nicholas Josten at 760-839- 4655 or [email protected]. Further instructions will be provided upon scheduling.
E. Contract Price and Payment Terms
The contract price of this First Amendment shall not exceed $55,889,697. The contract price of this First Amendment ($55,889,697) will bring the total contract price of the Agreement to $55,889,697. The contract price of this First Amendment includes all labor, materials, equipment, and transportation required to perform the work. Services will be billed as services are performed. Payment will be made after services have been performed and within 30 days of receipt of an invoice for those services.
F. Term
The term of this First Amendment shall be from the Effective Date of the this First Amendment through March 1, 2029.
33 Item5.
City of Escondido | Citywide Energy Roadmap
FIRST AMENDMENT TO THE ENERGY SERVICES AGREEMENT
ATTACHMENT A / EXHIBIT 1
For Council Consideration on August 20, 2025
34 Item5.
TABLE OF CONTENTS
TAB A: COVER LETTER
TAB B: PROGRAM SUMMARY............................................................................................................
TAB C: DETAILED SCOPE.................................................................................................................. • ATTACHMENT A: SCOPE BY FACILITY & MEASURE ....................................................... • ATTACHMENT B: SOLAR INSTALLATION ...................................................................... • ATTACHMENT C: LIGHTING SUMMARY....................................................................... • ATTACHMENT D: HVAC REPLACEMENT INVENTORY.................................................... • ATTACHMENT E: TECHNICAL APPENDIX ......................................................................
TAB D: PRELIMINARY SCHEDULE .......................................................................................................
TAB E: PAYMENT BOND ...................................................................................................................
TAB F: PERFORMANCE BOND ..........................................................................................................
TAB H: M&V AGREEMENT................................................................................................................. 35 Item5.
6/27/2025
Christopher McKinney
Deputy City Manager
City of Escondido
201 N. Broadway
Escondido, CA 92025-2798
Dear Chris,
Thank you for your team's collaboration over the last 18 months to develop a Citywide Energy Roadmap (“the program”). Together we completed the following steps of the program development process in preparation for implementation:
▪ Utility Baseline Development & Rate Analysis
▪ Engineering and Site-Level Assessments
▪ Staff Departmental Interviews
▪ Feasibility Studies and Financial Modeling
▪ Development and Validation of Scope of Work
▪ Competitive Financing Solicitation via Municipal Advisor ▪ Legal and Due Diligence Review Process
After the January 2025 study session, Council directed Staff to finalize the scope of work and funding plan with the intent to take action this summer. In order for Council to authorize program implementation, a Government Code 4217 public hearing is required, public notice for which must be posted 14 days prior. After the public hearing is conducted, Council may consider adoption of a resolution to make certain findings and approve the agreements for Climatec and the associated financing agreements.
Please see our enclosed proposal for implementing the Citywide Energy Roadmap. The Energy Services Agreement, originally executed in March 2024, shall be amended to include terms relevant to construction and program implementation, a detailed scope of work, technical appendices, and measurement & verification protocols.
If authorized by Council, a kickoff meeting with key city stakeholders would be conducted before commencing construction mobilization efforts. The construction duration is expected to take 24-36 months depending on equipment lead times and other factors such as utility interconnection.
We are excited to bring your program to fruition and help the City achieve its strategic objectives. Let us know if you have any questions.
Regards,
Ashley Lough
Ashley Lough
Director of Energy Services | Direct: (602) 400-2859 | [email protected] 36 Item5.
CITY OF ESCONDIDO
RFP 23-04 Citywide Energy Roadmap
Please see program summary documents including final scope of work and funding plan.
These documents were presented to Staff in May 2025 after the completion of the Detailed Assessment.
37 Item5.
August 12, 2025
BUILDING AUTOMATION SYSTEM (BAS) − New BAS at 16 Sites
− Convert Pneumatic Controls to DDC/ Integrate into BAS at 2 Sites
HEATING, VENTILATION & AIR CONDITIONING
(HVAC)
− HVAC System Retro-commissioning at 3 Sites
− New High Efficiency HVAC Units at 21 Sites
− Central Plant Modernization & Electrical Upgrades at 2 Sites
LIGHTING
− Interior LED Lighting at 26 Sites
− Exterior LED Lighting at 26 Sites
− Occupancy Sensors/ Dimming Control at 17 Sites
− New Sports Field LED Lighting at 3 Sites
RENEWABLES + ELECTRIC VEHICLE (EV)
INFRASTRUCTURE
− Solar PV Systems at 6 Sites
− Electric Vehicle (EV) Chargers at 10 Sites
POWER RESILIENCY / ELECTRICAL SYSTEMS − Microgrid System (Backup Power) at 4 Sites − New High Efficiency Transformers at 10 Sites
BUILDING ENVELOPE − Modernize Roof (Recoat) at 3 Sites
WATER TREATMENT PLANT & SYSTEM
− New High Efficiency Wash Water Recovery Pump Modernizations & VFDs − New High Efficiency Wash Water Pump Modernizations & VFDs − Hydraulic Model Development & System Recommissioning
WASTEWATER TREATMENT FACILITY (HARRF) &
SYSTEM
− New High Efficiency Blowers & Control
− Aeration Basin Enhancement w/ Electric Mixers & Baffle System Modernization − New RAS & WAS High Efficiency Pump Modernization
− Dissolved Oxygen (DO) Control Study & Optimization
− High Strength Waste (HSW) Receiving Station & System
− Bioenergy Facility Assessment & Study
TOTAL INFRASTRUCTURE MODERNIZATIONS − $ 55,889,697
LIFECYCLE SAVINGS − $ 83,601,487
38 Item5.
June 25, 2025
FUNDING SOURCES
− Municipal Lease-Purchase
− Measure I
− City Contributions
− Guaranteed Savings
% OF TOTAL PROGRAM BY FUND
− General Fund: 67%
− Water Enterprise Fund: 9%
− Wastewater Enterprise Fund: 24%
% OF OPERATING SAVING BY FUND
− General Fund: 74%
− Water Enterprise Fund: 1%
− Wastewater Enterprise Fund: 25%
OTHER PROGRAM BENEFITS
− Leverage Measure I & guaranteed savings to help eliminate structural deficit − Hedge against construction price inflation & utility rate increases − Remedy over $40 million in failing infrastructure & deferred maintenance needs − Expedite implementation and eliminate change order risk − Improve essential services, promote public safety & attract development − Meet State mandates & demonstrate environmental stewardship − Reduced carbon footprint by 9,158,423 pounds of CO₂ equivalent − Promote Staff & operational efficiency
39 Item5.
June 25, 2025
General
Fund
67%
Water Enterprise
9%
Wastewater
Enterprise
24%
General
Fund
74%
Water Enterprise
1%
Wastewater
Enterprise
25%
40 Item5.
June 25, 2025
BUILDING AUTOMATION
SYSTEMS (BAS) $3,056,516
HVAC $5,094,193
LIGHTING $7,131,871
BUILDING ENVELOPE $1,018,839
RENEWABLES &
EV INFRASTRUCTURE $15,792,000
POWER RESILIENCY/
ELECTRICAL SYSTEMS $5,603,613
WTP & SYSTEM $5,094,194
WWTP & SYSTEM $13,098,470
HVAC
9.11% BAS
5.47%
Lighting
12.76%
Building
Envelope
1.82%
Power Resiliency
/ Electrical
Systems
10.03%
Renewables &
EV Infrastructure
28.26%
WTP & System
9.11%
WWTP & System
23.44%
41 Item5.
CITY OF ESCONDIDO
RFP 23-04 Citywide Energy Roadmap
The Citywide Energy Roadmap detailed scope is outlined in the following attachments:
A. SCOPE BY FACILITY & MEASURE
B. SOLAR INSTALLATION
C. LIGHTING SUMMARY
D. HVAC REPLACEMENT INVENTORY
E. TECHNICAL APPENDIX
42 Item5.
City of Escondido
Amendment 1 –Attachment A
Attachment “A”
Scope by Facility & Measure
43 Item5.
City of Escondido
Amendment 1 –Attachment A
Water Treatment Plant
Wash Water Recovery Pump VFD Upgrades
▪ Replace three (3) existing PSC motors with high efficiency induction motors and install Allen Bradley Variable Frequency Drives (VFDs) to modulate flow rate based on plant demand.
The Scope of Work includes:
• Demolition and disposal of existing Wash Water Recovery pump motors. • Install new, high-efficiency induction pump motors on three (3) existing pumps (2 @ 150 HP, 1 @ 100 HP).
• Reuse existing motor electrical feeders.
• Install new concrete pad and canopy adjacent to existing electrical enclosure to house three (3) new VFD cabinets.
• Install outdoor-rated VFD cabinets with integral cooling systems. • Install additional control wiring to support VFDs.
• Program VFDs using set points provided by plant personnel. • Demolition of electrical panels in existing enclosure. Enclosure to remain.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • System integration (PLC). To be performed by plant personnel. • Demolition of existing electrical equipment enclosure.
Wash Water Pump VFD Upgrades
▪ Replace one (1) of the 60 HP pumps and associated motor (P-7) with one (1) new optimally sized, high efficiency, 40 HP pump and induction motor. Install new Allen Bradley VFD on existing 40 HP Wash Water pump and the new 40 HP Wash Water pump to modulate flow rate based on plant demand. Install Reduced Voltage Soft Starter (RVSS) on remaining existing 60 HP pump.
The Scope of Work includes:
• Demolition of one (1) 60 HP pump (P-7 or P-8) and associated motor. • Install new 40 HP pump, to replace the previous 60 HP pump, and induction motor to match existing P-33 pump and motor.
• Reuse existing motor electrical feeders.
• Install new VFDs on East wall of electrical room to serve new and existing 40 HP pumps. • Install RVSS on existing 60 HP pump.
• Remove and replace existing wiring from VFDs and Soft Starters to pump motors. • Install additional control wiring to support VFDs.
• Program VFDs using set points provided by plant personnel. 44 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • System integration (PLC). To be performed by plant personnel.
Update City’s Hydraulic Model
Convert and update the City’s existing hydraulic model, the latest version of which was developed using H2OMap to support the City’s 2012 Master Plan and recalibrate to reflect modifications made to the system to date. This effort is based on the following:
• The City’s water distribution system is comprised of approximately 440 miles of pipeline with 25,000 service meters, 5 pump stations, 11 reservoirs, and 50 pressure control stations. • Import assets from H2OMap model into InfoWater Pro, the City’s selected modeling platform and update to reflect current conditions. Updates will be based on record drawings and available data, including but not limited to: GIS data of system assets, operational controls (e.g., pressure-reducing valve settings), land use data to assign demand use type and appropriate fire flows. • Analysis of the following demand scenarios during both winter and summer: Average Day Demand (ADD), Maximum Day Demand (MDD), and Peak Hour Demand (PHD). • Calibrate model to steady-state conditions for above demand scenarios using results from fire hydrant flow test. Climatec’s engineers will prepare a hydrant testing plan and assist City staff in performing the flow tests. It is assumed District staff will provide the equipment and operate the valves, and that Climatec’s engineers will assist and record the results. • Once calibrated, run the model for the following scenarios:
o Existing seasonal demands (ADD, MMD, PHD) during both summer and winter. o Fire flow analysis to verify model can be used to estimate available fire flow during MDD.
o Up to ten (10) future model scenarios as determined by Climatec’s engineers and the City to identify energy savings opportunities.
• Develop draft and final TM summarizing model updates, recalibration, and results of future scenarios to identify energy savings opportunities.
• Develop a Water System Hydraulic Model Reference Manual to include:
o Description of the model development process.
o Model calibration results.
o Workflow documentation for the City to perform model runs. o Workflow documentation for the City to add features, perform model updates, and recalibrate the model.
• Provide hydraulic model training at the City’s offices covering the use of the model. To include three separate four (4)-hour sessions.
• Provide draft and final hydraulic model report.
45 Item5.
City of Escondido
Amendment 1 –Attachment A
Lighting
▪ Retrofit identified interior T8, T12, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
Mechanical
▪ Replace three (3) mini-split heat pump systems with new high efficiency units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. ▪ Replace two (2) packaged gas / electric units with new high efficiency packaged heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Curb modifications, rigging, setting new units onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
46 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
Controls
▪ Provide and install nine (9) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Transformers
▪ Replace five (5) existing transformers with new equal capacity high efficiency transformers. The new transformers will be of the same electrical configuration and be placed in the same location and fit within existing constraints as the existing transformers.
The Scope of Work Includes:
• Remove and dispose of existing transformers.
• Installation of new dry type, low loss, high efficiency transformers. • Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
• Compliance with all state, local electric codes.
The Scope of Work Excludes:
• Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
Hale Avenue Resource Recovery Facility (HARRF)
Blower Replacement
▪ Replace three (3) existing Turblex blowers with two (2) APG Neuros dual core high speed turbo blowers.
47 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work includes:
• Demolition and disposal of the three (3) existing Turbo Blowers • Demolition of existing blower silencer discharge.
• Demolition of existing concrete blower support pads.
• Demolition of existing blower control panels
• Installation of two (2) APG Neuros (2x330 HP) dual core high speed turbo blowers equipped with Allen Bradley VFDs. Including all required inlet & discharge check and butterfly valves and expansion joints, and Allen Bradley PLC control panel. • Existing conduit and wiring to be reused.
• Construct or modify existing air inlet and outlet piping to accommodate installation of new blowers. Main header to remain unchanged.
• Duct modifications as needed to reconnect new blowers. • Reconfigure existing blower soft-start panels to be in-line. • Installation of new concrete pads and anchorage.
• Installation of inlet and discharge valves and expansion joints. • Reconfigure existing blowers Master PLC to communicate with new Neuros control panels.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • System integration (PLC). To be performed by plant personnel. • SCADA programming. To be performed by plant personnel.
Aeration Basin Mixing
▪ Replace coarse bubble diffusers in first zone of each aeration basin with electric mixers.
The Scope of Work includes:
• Demolish existing coarse aeration diffusers and piping (including supports) downstream of isolation air valve.
• Remove existing isolation air valve and install blind flange. • Install new conduits and wiring to electrical room in Blower Building utilizing existing overhead support system.
• Install five (5) new submersible mixers on slide rails – one (1) mixer for each process train.
Motors to be equipped with soft starters.
• Replace existing baffling systems along first wall in each basin train with in-kind redwood system.
48 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Replacing or repairing inoperable isolation gates. Assumption is that existing isolation gates to each basin provide adequate seal for construction purposes. • Preparation of aeration basin for work to be performed. City to drain basins, remove accumulated debris, and wash down.
• Filling of Basin. Once mixer and baffle installation is complete, plant personnel are to fill basin and return to service.
• System integration (PLC). To be performed by plant personnel. • SCADA programming. To be performed by plant personnel.
RAS & WAS Pump Replacements
▪ Replace the six (6) Return Activated Sludge (RAS) pumps serving Clarifiers 1-4 and the two (2) Waste Activated Sludge (WAS) pumps and their associated VFDs.
The Scope of Work includes:
• Demolition of existing RAS and WAS pumps, motors, and VFDs including disposal. • Demolition of existing concrete pump support pads.
• Demolition of existing seal water system.
• Installation of three (3) 60 HP RAS pumps to serve secondary clarifiers 3 & 4. • Installation of three (3) 25 HP RAS pumps to serve secondary Clarifiers 1 & 2. • Installation of two (2) 40 HP WAS pumps.
• Installation of eight (8) new Allen Bradley VFDs to serve the new pumps in the existing electrical Bldg. currently serving the existing RAS & WAS pumps. • Modify or replace the existing RAS and WAS pump inlet and outlet piping to accommodate the new pumps.
• Install new seal water system as needed.
• Reuse existing E-Stops.
• Reuse existing VFD’s conduit and wiring.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Pipe modifications downstream of pump discharge connection. • Pressure monitoring changes to current configuration. • Additional HOA switches
• Removal of existing RAS & WAS pump wiring.
• System integration (PLC). To be performed by plant personnel. • SCADA programming. To be performed by plant personnel. 49 Item5.
City of Escondido
Amendment 1 –Attachment A
High Strength Waste Retrofit
▪ Install additional 10,000-gallon High Strength Waste storage tank.
The Scope of Work includes:
• Install new reinforced concrete pad to support new storage tank. • Install new 10,000-gallon capacity Fiberglass Reinforced Plastic (FRP) tank with mechanical mixer.
• Install combined macerator and solids separator system in-line and upstream of new tank. • Extend new piping to inlets at both, the existing Tank and new Tank. • Install Two (2) new 4" plug valves downstream of Macerator to control waste stream flow direction to either tank.
• Reuse existing tank piping.
• Power and controls for macerator and tank mixer to run to electrical room on second floor of adjacent building.
• Local control panels to be installed for new macerator and tank mixer.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Providing level switches
• System integration (PLC). To be performed by plant personnel. • SCADA programming. To be performed by plant personnel.
Secondary Treatment Process Model
▪ Develop a baseline process model for the HARRF that allows evaluation of the activated sludge secondary treatment system. The model is anticipated to be a dynamic model calibrated to current conditions. The model will be developed using a commercially available wastewater process simulator, such as BioWin or GPS-X.
Once developed and calibrated, the process model will be used to simulate operational changes (e.g., reduced concentrations of dissolved oxygen and/or RAS flowrates) within the activated sludge process to identify potential cost savings while complying with regulatory discharge requirements. Scenarios that contemplate structural changes to the process train will not be evaluated under this task.
Draft and final versions of a process model report will be prepared that document the model structure, assumptions, raw analytical and operating data used for calibration, as well as calibration results. The report will also summarize the results of simulated operational changes with associated cost savings for each scenario. 50 Item5.
City of Escondido
Amendment 1 –Attachment A
Bioenergy Facility Assessment
▪ Review the City of Escondido’s bioenergy facility purchase agreement. Review will assess the efficiency and effectiveness of the installed bioenergy system, including gas conditioning equipment, and quality of the existing biogas. Biogas quality review will include testing for compatibility with the existing bioenergy system.
This assessment will include the following tasks:
• Review of available documents.
• Site visit to bioenergy facility, located at HARRF.
• Biogas sampling and testing.
• Draft and final report of findings for
1) bioenergy system assessment, and
2) biogas quality
Deliverables:
• Draft and final geotechnical report.
• Draft and final process model report.
• Draft and final bioenergy facility assessment report.
Assumptions related to process model development:
• Level of effort assumes BioWin or GPS-X wastewater modeling simulation software.
• City to provide current conditions datasets in spreadsheet format. • Field work and/or sampling to validate model is not included in the scope of work.
• Project schedule assumes two-week review time by the City for each deliverable. • Fee schedule includes time to compile, sign, and transfer deliverables. • QA/QC review time from senior staff.
Lighting
▪ Retrofit identified interior T8, HID, and incandescent lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified building and pole mounted HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
51 Item5.
City of Escondido
Amendment 1 –Attachment A
Mechanical
▪ Replace one (1) split-system heat pump with new high efficiency unit of similar size and capacity of previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new unit and connection to existing BAS.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
▪ Replace two (2) packaged gas / electric units with new high efficiency packaged heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Curb modifications, rigging, setting new units onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new units and connection to the existing BAS.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
52 Item5.
City of Escondido
Amendment 1 –Attachment A
Transformers
▪ Replace five (5) existing transformers with new equal capacity high efficiency transformers. The new transformers will be of the same electrical configuration and be placed in the same location and fit within existing constraints as the existing transformers.
The Scope of Work Includes:
• Remove and dispose of existing transformers.
• Installation of new dry type, low loss, high efficiency transformers. • Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
• Compliance with all state, local electric codes.
The Scope of Work Excludes:
Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
City Hall / CCAE Complex - Central Plant
Lighting
▪ Retrofit identified interior T5 lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building mounted HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Mechanical
▪ Replace two (2) 350-ton existing natural gas (NG) chillers with new electric high efficiency magnetic bearing chillers of similar size and capacity.
The Scope of Work Includes:
• Engineering design
• Demolition, removal and disposal of the existing chillers. Disposal of refrigerant will be in conformance with EPA regulations.
• Demolition of existing Heat Recovery system with piping capped at wall penetration. • Demolition of existing natural gas piping to wall penetration and capped. • New electrical connections, including electrical modifications and upgrades to supply required electrical service to operate the new chillers. • Insulate all new or exposed Chilled Water (CHW) piping affected by the installation of the new equipment.
53 Item5.
City of Escondido
Amendment 1 –Attachment A
• Connect to existing controls and implement programming and graphics. • Start-up, testing of the new chillers. Commissioning to be part of building retrocommissioning scope.
The Scope of Work Excludes:
• Any CHW piping repair outside the central plant or not directly associated with scope. ▪ Replace one (1) existing 60-ton air cooled (DX) chiller with a high efficiency DX scroll chiller of similar capacity.
Scope of Work Includes:
• Engineering design.
• Demolition, removal and disposal of the existing chiller and appurtenances. Disposal of refrigerant will be in conformance with EPA regulations. • Electrically reconnect new chiller, including electrical modifications as necessary to allow for proper operation of new chiller.
• Piping reconfiguration and modifications as required for installation of the new chiller. • Insulate any new or exposed Chilled Water (CHW) piping affected by the installation of the new equipment.
• Reconnect to existing controls and reprogram.
• Start-up, testing of the new chillers. Commissioning to be part of building retrocommissioning scope.
Scope of Work Excludes:
• Any CHW piping repair outside the central plant or not directly associated with scope. ▪ Replace two (2) 375 GPM / 5HP, one (1) 130 GPM / 3HP, and one (1) 486 GPM / 3HP primary Chilled Water (CHW) pumps and two (2) 580 GPM / 40HP secondary CHW pumps with new high efficiency pumps of similar capacity.
The Scope of Work Includes:
• Engineering design.
• Demolition, removal and disposal of the existing CHW pumps. • Electrical disconnect / reconnect.
• Piping modifications as required.
• Insulate any new or exposed Chilled Water (CHW) pipe affected by the installation of the new equipment.
• New premium efficiency inverter duty motors.
• Reconnect existing VFDs to each pump and program.
• Balancing of CHW system.
• Replenish / fill CHW loop to required volume.
• Coordinate with City’s Chemical Treatment contractor (at City’s expense) to treat CHW loop prior to start up.
54 Item5.
City of Escondido
Amendment 1 –Attachment A
• Start-up, testing of the new pumps. Commissioning to be part of the building’s retrocommissioning scope.
The Scope of Work Excludes:
• Draining or flushing of CHW loop
▪ Replace two (2) 985 GPM / 15HP and one (1) 486 GPM / 7.5HP Condenser Water (CW) pumps with new high efficiency pumps of similar capacity.
The Scope of Work Includes:
• Engineering design.
• Demolition, removal and disposal of the existing CW pumps. • Electrical disconnect and reconnect.
• Piping modifications as required.
• Insulate any new or exposed Condenser Water (CW) pipe affected by the installation of the new equipment.
• New premium efficiency inverter duty motors.
• Reconnect existing VFD for each pump and program.
• Balancing of CW system.
• Replenish/fill CW loop to required volume.
• Coordinate with City’s Chemical Treatment contractor (at City’s expense) to treat CHW loop prior to start up.
• Start-up, testing the new pumps. Commissioning to be part of the building’s retrocommissioning scope.
The Scope of Work Excludes:
• Draining or flushing of CW loop
▪ Replace two (2) 320 GPM / 15HP Heating Hot Water (HHW) pumps with new high efficiency HHW pumps of similar capacity.
The Scope of Work Includes:
• Engineering design
• Demolition, removal and disposal of the existing HHW pumps. • Electrical disconnect and reconnect.
• Piping modifications as required.
• Insulate any new or exposed Heating Hot Water (HHW) pipe affected by the installation of the new equipment.
• New premium efficiency motors.
• Balancing of HHW system.
• Replenish/fill HHW loop to required volume.
55 Item5.
City of Escondido
Amendment 1 –Attachment A
• Coordinate with City’s Chemical Treatment contractor (at City’s expense) to treat CHW loop prior to start up.
• Start-up, testing the new pumps. Commissioning to be part of the building’s retrocommissioning scope.
The Scope of Work Excludes:
• Draining or flushing of HHW loop.
Install one (1) new 1,900 MBH 84% efficiency, conventional natural gas-fired, force draft boiler on upper deck of central plant.
Scope of Work Includes:
• Engineering design.
• Installation of new boiler.
• Installation of new concrete equipment pad.
• Installation of new electrical circuit and natural gas pipe per engineers’ design. • New piping from existing HHW loop to new boiler.
• Insulation of any new or exposed HHW pipe affected by the installation of the new equipment.
• Installation of new flue.
• Installation of circulation pump per engineer’s design. • Start-up and testing.
Scope of Work Excludes:
• Any HHW piping repair outside the central plant or not directly associated with scope. ▪ Refurbish three (3) existing cooling towers.
Scope of Work Includes:
• Demolition of the Drift eliminators, fill media.
• Removal of air inlet louvers.
• Demolition of the fan motor, fan assembly, shaft kit w/bearings. • Remove all sealant from interior seams.
• Install new fan assembly, fan motor, shaft, sheaves and bearings. • Install new fill media and drift eliminators.
• Clean and inspect the hot water distribution system. Replace any damaged nozzles. • Install new louver media.
• Apply a new sealant bead with ACT double sealer process on all interior casing seams. • Install a new float valve assembly.
• Make minor adjustments as necessary to ensure proper operation of the system. • Coordinate with City’s Chemical Treatment contractor (at City’s expense) to treat CW loop prior to start up.
56 Item5.
City of Escondido
Amendment 1 –Attachment A
• Start-up and testing of the refurbished cooling towers. Commissioning to be part of the building’s retro-commissioning scope.
Scope of Work Excludes:
• Replacement of cooling tower basins
RCx Study and Implementation
▪ Perform Retro-commission (RCx) study and report to systematically identify, document, and recommend operational measures with the intent of improving building performance and optimizing the building’s HVAC and Controls systems.
The Retro-commissioning process will include testing and measuring the plant’s water, and control systems in their current operating condition. Measures requiring capital improvements may be identified and recommended through the process.
Transformers
▪ Replace one (1) existing transformer with a new equal capacity high efficiency transformer. The new transformer will be of the same electrical configuration and be placed in the same location and fit within existing constraints as the existing transformer.
The Scope of Work Includes:
• Remove and dispose of existing transformer.
• Installation of new dry type, low loss, high efficiency transformer. • Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
• Compliance with all state, local electric codes.
The Scope of Work Excludes:
• Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
57 Item5.
City of Escondido
Amendment 1 –Attachment A
Power Resiliency / Back Up Power
▪ Provide and install one (1) new permanently connected backup generator to provide automatic emergency backup power to the Central Plant.
The Scope of Work includes:
• Provide and install one (1) new 1000kW natural gas generator. Exact location to be determined during design with coordination from City. Assumed generator location will be within 180 ft of current location of MS1 & MS2 electric meter and within the gated area of the central plant parking area.
• Provide and install one (1) new 1200 Amp and one (1) new 800 Amp 3-pole automatic transfer switch (ATS).
• Provide and install necessary materials to connect the new generator and ATS to the main switchgear.
• Provide concrete pad for the new generator.
• Provide new bollards as required.
• Provide and install new natural gas piping from the generator to the existing natural gas service.
• Start-up/testing of the new generator.
• New generator and ATS specifications to be determined upon final engineering design.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications.
Renewables
Central Plant Meter #1
▪ Provide and install a new 123.1 kWDC solar PV carport system in the parking lot adjacent to the central plant between Woodward Ave. & N. Escondido Blvd. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s).
Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection.
Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Removal, demolition, and haul away of (10) existing exterior light poles and (10) small sized trees that coincide with proposed carport-mounted solar PV system. • Installation of solar PV array on structural steel carports located in the large Woodward Ave.
CCAE parking lot across the pedestrian bridge.
• Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. • Installation of data acquisition system to provide system performance monitoring. 58 Item5.
City of Escondido
Amendment 1 –Attachment A
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements, or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Central Plant Meter #2
▪ Provide and install a new 272.1 kWDC solar PV carport system in the parking lot adjacent to the central plant between Woodward Ave. & N. Escondido Blvd. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s).
Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection.
Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Removal, demolition, and haul away of (4) existing exterior light poles and (18) small sized trees that coincide with proposed carport-mounted solar PV system. • Installation of solar PV array on structural steel carports located in the large Woodward Ave.
CCAE parking lot across the pedestrian bridge.
• Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. • Installation of data acquisition system to provide system performance monitoring.
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements, or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
California Center for the Arts Escondido (CCAE)
Lighting
▪ Retrofit identified interior T5, T8, CFL, HID, and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building mounted T8 and CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Controls
▪ Replace existing pneumatically controlled valves and dampers with direct digital controls (DDC). 59 Item5.
City of Escondido
Amendment 1 –Attachment A
Location
AHU
CHW Coil HHW
Coil
VAV VAV
w/Reheat
Reheat
Valves
Econ.
Dampers
Arts Bldg. 2 0 12 10 4 6
Conference Ctr 2 1 0 16 0 6
Community Theater 7 3 0 28 1 12
Lyric Theater 6 2 59 58 13 18
Total Pneumatic
Devices 17 6 71 112 18 42
The Scope of Work includes:
• Demolition of HHW, CHW, and reheat valves and pneumatic actuators associated with the buildings air handlers and reheat coils.
• Provide and Install new HHW, CHW, and Reheat valves with DDC actuators including wiring the DDC actuators to the local building automation controller or control device. • Disconnect and remove the existing pneumatic actuators serving the VAV boxes and economizer dampers associated with the building’s air handlers. • Provide and Install new DDC actuators, to include wiring from the actuators to the local controller serving the VAV boxes and economizer dampers. • Provide and install new DDC wirelessly communicating terminal control devices on the VAV boxes, to include wiring power to the controller.
• Re-insulate HHW/CHW supply & return piping where existing insulation has been damaged or removed as a result of the new valves.
• Disposal of air compressors
• Integration of new devices to buildings existing building automation system. • Programming and graphics of new devices
• Perform functional testing and calibrate actuators.
The Scope of Work excludes:
• Electrical work beyond the scope of the control system replacement. • Replacement of equipment not directly related to controls.
RCx and TAB Study and Implementation
▪ Perform a Retro-commission (RCx) study and report to systematically identify, document, and recommend operational measures with the intent of improving building performance and optimizing each building’s HVAC and Controls systems.
The Retro-commissioning process will include testing and measuring each building’s air, water, and control systems in their current operating condition. Measures requiring capital improvements may be identified and recommended through the process.
60 Item5.
City of Escondido
Amendment 1 –Attachment A
▪ Test and Balance (TAB) A complete building TAB will be performed by a certified TAB contractor as part of the RCx process. The results of this analysis will be documented in a certified TAB report and utilized in assessing building operational and optimization measures identified through the RCx study.
• Optimize existing control system by verifying control sequences, implementing energy saving strategies, modifying set points and updating schedules per the Standard of Operations and based on the retro-commissioning report. • Replacement of failed devices and equipment is not included. • A system deficiency list will be provided as part of this scope. • Climatec does not warrant the performance of the existing controls system.
Transformers
▪ Replace five (5) existing transformers with new equal capacity high efficiency transformers. The new transformers will be of the same electrical configuration and be placed in the same locations and fit within existing constraints as the existing transformers.
The Scope of Work Includes:
• Remove and dispose of existing transformers.
• Installation of new dry type, low loss, high efficiency transformers. • Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
• Compliance with all state, local electric codes.
The Scope of Work Excludes:
• Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
Roof Recoating
▪ Coat all existing built-up flat roof areas of each of the Performing Arts Building’s with fluid applied roofing.
Scope of Work Includes:
• Preparation of existing built-up roof to include removal of dirt, debris, and gravel. • Pressure wash built-up roof surfaces to be coated.
• Remove and reinstall counterflashing as needed.
• Seal pipes, vents, and other roof equipment.
• Cut blisters and seal as needed.
• Apply silicone coating per manufacturer’s guidelines to required thickness. • Reseal top of counterflashing as needed.
61 Item5.
City of Escondido
Amendment 1 –Attachment A
Scope of Work Excludes:
• Structural repairs.
• Repairs or coating of standing seam roof areas.
• Asbestos and/or lead abatement.
EV Charging
Concert Hall
▪ Provide and install three (3) dual-port and two (2) single-port Level 2 EV charging stations at the CCAE for public use. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed in the CCAE parking lot off Woodward Ave. • Provide and install three (3) dual-port and two (2) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install five (5) concrete bases to support the EV pedestals. • Provide ADA stall restripes for (1) Van and (1) Standard ADA accessible EV charging stalls. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Conference Center
▪ Provide and install one (1) dual-port and one (1) single-port Level 2 EV charging stations at CCAE for public use. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed in the Conference Center Parking lot beneath the new solar PV carport.
• Provide and install one (1) dual-port and one (1) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install two (2) concrete bases to support the EV pedestals. 62 Item5.
City of Escondido
Amendment 1 –Attachment A
• Provide ADA stall restripes for (1) Van ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements, or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Renewables
Conference Center
▪ Provide and install a new 99.9 kWDC solar PV carport system. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s).
Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection.
Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Removal, demolition, and haul away of (2) existing exterior light poles that coincide with proposed carport-mounted solar PV system.
• Installation of solar PV array on structural steel carport over the parking island in the Conference Center parking lot.
• Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. • Installation of data acquisition system to provide system performance monitoring. • Provide ADA stall restripe under proposed solar PV carport and path-of-travel (POT) linkage from said stall to nearest existing ADA POT.
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Concert Hall
Provide and install a new 298.1 kWDC solar PV carport system in the parking lot adjacent to the central plant between Woodward Ave. & N. Escondido Blvd. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s). 63 Item5.
City of Escondido
Amendment 1 –Attachment A
Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection. Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Removal, demolition, and haul away of (10) existing exterior light poles and (25) small sized trees that coincide with proposed carport-mounted solar PV system. • Installation of solar PV array on structural steel carports located in the large Woodward Ave.
CCAE parking lot across the pedestrian bridge.
• Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. • Installation of data acquisition system to provide system performance monitoring.
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements, or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Museum
▪ Provide and install a new 162.0 kWDC solar PV carport system in the parking lot adjacent to the central plant between Woodward Ave. & N. Escondido Blvd. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s).
Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection.
Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Removal, demolition, and haul away of (1) existing exterior light poles and (11) small sized trees that coincide with proposed carport-mounted solar PV system. • Installation of solar PV array on structural steel carports located in the large Woodward Ave.
CCAE parking lot across the pedestrian bridge.
• Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. • Installation of data acquisition system to provide system performance monitoring.
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements, or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code. 64 Item5.
City of Escondido
Amendment 1 –Attachment A
Theater
▪ Provide and install a new 136.0 kWDC solar PV carport system in the parking lot adjacent to the central plant between Woodward Ave & N. Escondido Blvd. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s).
Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection.
Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Removal, demolition, and haul away of (3) existing exterior light poles and (9) small sized trees that coincide with proposed carport-mounted solar PV system. • Installation of solar PV array on structural steel carports located in the large Woodward Ave.
CCAE parking lot across the pedestrian bridge.
• Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. • Installation of data acquisition system to provide system performance monitoring.
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements, or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
City Hall
Lighting
▪ Retrofit identified interior T8, CFL, and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building mounted T8, CFL, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Mechanical
▪ Replace two (2) existing mini split heat pump units with new high efficiency units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
65 Item5.
City of Escondido
Amendment 1 –Attachment A
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new units and connection to the existing building automation system The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. ▪ Replace one (1) existing packaged heat pump serving the City Hall server room with a new high efficiency unit of similar size and capacity of the previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Curb modifications, rigging, setting new unit onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Duct modifications as needed for proper fit.
• Condensate connections.
• Start-up/testing of the new unit and connection to the existing building automation system.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Duct repairs not directly related to the scope of work. • Any required programming or system upgrades to the existing fire alarm system. ▪ Replace one (1) existing 40-ton air cooled (DX) chiller with a high efficiency DX scroll chiller of similar capacity.
Scope of Work Includes:
• Engineering design
• Demolition, removal and disposal of the existing chiller. Disposal of refrigerant will be in conformance with EPA regulations.
66 Item5.
City of Escondido
Amendment 1 –Attachment A
• Electrical disconnect / reconnect new chiller, including electrical modifications to allow proper operation of new chiller.
• Piping reconfiguration and modifications as required for installation of the new chiller • Insulate any new or exposed Chilled Water (CHW) piping affected by the installation of the new equipment.
• Reconnect to existing controls.
• Start-up, testing of the new chillers. Commissioning to be part of building retrocommissioning scope.
Scope of Work Excludes:
• Any CHW piping repair outside the central plant or not directly associated with scope.
Controls
▪ Replace existing pneumatically controlled valves and dampers with direct digital controls (DDC).
Location
AHUs
CHW Coil HHW
Coil
VAV Econ.
Dampers
City Hall 8 8 8 24
Total Pneumatic
Devices 8 8 8 24
The Scope of Work includes:
• Demolition of HHW, CHW, and pneumatic actuators associated with the buildings air handlers
• Provide and Install new HHW and CHW valves with DDC actuators including wiring the DDC actuators to the local building automation controller. • Disconnect and remove the existing pneumatic actuators serving the existing VAV boxes and economizer dampers associated with the building’s air handlers. • Provide and Install new DDC actuators, to include wiring from the actuators to the local controller serving the VAV boxes and economizer dampers. • Provide and install new DDC wirelessly communicating terminal control devices on the VAV boxes, to include wiring power to the controller.
• Re-insulate HHW/CHW supply & return piping where existing insulation has been damaged or removed as a result of the new valves.
• Disposal of air compressors
• Integration of new devices to buildings existing building automation system. • Programming and graphics of new devices
• Perform functional testing and calibrate actuators.
The Scope of Work excludes:
• Electrical work beyond the scope of the control system replacement. • Replacement of equipment not directly related to controls. 67 Item5.
City of Escondido
Amendment 1 –Attachment A
RCx and TAB Study and Implementation
▪ Perform a Retro-commission (RCx) study and report to systematically identify, document, and recommend operational measures with the intent of improving building performance and optimizing each building’s HVAC and Controls systems.
The Retro-commissioning process will include testing and measuring each building’s air, water, and control systems in their current operating condition. Measures requiring capital improvements may be identified and recommended through the process.
▪ Test and Balance (TAB) A complete building TAB will be performed by a certified TAB contractor as part of the RCx process. The results of this analysis will be documented in a certified TAB report and utilized in assessing building operational and optimization measures identified through the RCx study.
• Optimize existing control system by verifying control sequences, implementing energy saving strategies, modifying set points and updating schedules per the Standard of Operations and based on the retro-commissioning report. • Replacement of failed devices and equipment is not included. • A system deficiency list will be provided as part of this scope. • Climatec does not warrant the performance of the existing controls system Transformers
▪ Replace six (6) existing transformers with new equal capacity high efficiency transformers. The new transformers will be of the same electrical configuration and be placed in the same locations and fit within existing constraints as the existing transformers.
The Scope of Work Includes:
• Remove and dispose of existing transformers.
• Installation of new dry type, low loss, high efficiency transformers. • Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
• Compliance with all state, local electric codes.
The Scope of Work Excludes:
• Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
Power Resiliency / Back Up Powers
▪ Provide and install one (1) new permanently connected 130kW backup generator with 600A automatic transfer switch (ATS) to provide automatic emergency backup power to the council chambers side of the building.
The Scope of Work includes:
68 Item5.
City of Escondido
Amendment 1 –Attachment A
• Provide and install one (1) new 130kW natural gas generator in the southwest corner of the east parking lot near the existing switchgear.
• Provide and install one (1) new 600Amp 3-pole automatic transfer switch (ATS). • Provide and install necessary materials to connect the new generator and ATS to the main switchboard.
• Provide concrete pad for the new generator.
• Provide new bollards as required.
• Provide and install new natural gas piping to connect the generator to the existing natural gas service.
• Start-up/testing of the new generator.
• New generator and ATS specifications to be determined upon final engineering design.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. ▪ Replace one (1) existing permanently connected 400kW backup generator with 1600A automatic transfer switch (ATS) to provide automatic emergency backup power to the administrative side of the building.
The Scope of Work includes:
• Demolition and disposal of the existing 400kW generator and ATS. • Provide and install one (1) new 400kW natural gas generator in the current location of the existing generator.
• Provide and install one (1) new 1600Amp 3-pole automatic transfer switch (ATS). • Provide and install necessary materials to connect the new generator and ATS to the main switchboard.
• Reuse existing concrete pad for the new generator.
• Reconnect natural gas piping to generator.
• Start-up/testing of the new generator.
• New generator and ATS specifications to be determined upon final engineering design.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications.
EV Charging
▪ Provide and install two (2) dual-port and one (1) single-port Level 2 EV charging stations at City Hall, for use with fleet, or authorized electrical vehicles only. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed in northeast City Hall service lot. • Provide and install two (2) dual-port and one (1) single-port EV charging station(s). 69 Item5.
City of Escondido
Amendment 1 –Attachment A
• Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install three (3) concrete bases to support the EV pedestals. • Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Renewables
▪ Provide and install a new 346.7 kWDC solar PV carport system in the parking lot adjacent to the central plant between Woodward Ave. and N. Escondido Blvd. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s).
Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection.
Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Removal, demolition, and haul away of (3) existing exterior light poles and (25) small sized trees that coincide with proposed carport-mounted solar PV system. • Installation of solar PV array on structural steel carports located in the large Woodward Ave.
CCAE parking lot across the pedestrian bridge.
• Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. • Installation of data acquisition system to provide system performance monitoring.
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements, or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code. 70 Item5.
City of Escondido
Amendment 1 –Attachment A
Daley Ranch Maintenance Facility
Lighting
▪ Retrofit identified interior T8 lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
Daley Ranch Historic House
Controls
▪ Provide and install one (1) new Wi-Fi smart thermostat w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostat.
• Install new locally mounted Wi-Fi smart thermostat to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Dixon Lake Cottage Rental
Mechanical
▪ Replace one (1) split-system heat pump with a new high efficiency unit of similar size and capacity of the previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Duct repair and air balancing.
• Roofing repairs not directly related to the scope of mechanical work. 71 Item5.
City of Escondido
Amendment 1 –Attachment A
Controls
▪ Provide and install one (1) new Wi-Fi smart thermostat w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostat.
• Install new locally mounted Wi-Fi smart thermostat to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Don E. Anderson Building
Mechanical
▪ Replace two (2) existing packaged heat pumps with new high efficiency units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Curb modifications, rigging, setting new units onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Duct repair and air balancing.
Controls
▪ Provide and install two (2) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
72 Item5.
City of Escondido
Amendment 1 –Attachment A
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Roof Recoating
▪ Coat existing built-up flat roof area of the Don E. Anderson building with fluid applied roofing.
Scope of Work Includes:
• Preparation of existing built-up roof to include removal of dirt, debris, and gravel. • Pressure wash built-up roof surfaces to be coated.
• Remove and reinstall counterflashing as needed.
• Seal pipes, vents, and other roof equipment.
• Cut blisters and seal as needed.
• Apply silicone coating per manufacturer’s guidelines to required thickness. • Reseal top of counterflashing as needed.
Scope of Work Excludes:
• Structural repairs.
• Asbestos and/or lead abatement.
East Valley Community Center (EVCC)
Lighting
▪ Retrofit identified interior T8 and CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building mounted CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
73 Item5.
City of Escondido
Amendment 1 –Attachment A
Mechanical
▪ Replace five (5) existing packaged gas / electric units with new high efficiency packaged heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Curb modifications, rigging, setting new units onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Cap existing gas lines.
• Condensate connections.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
Controls
▪ Replace existing Honeywell building automation controls serving the building’s rooftop packaged units.
Scope of Work Includes
• Removal and disposal of existing temperature sensors and terminal unit controllers. • Installation of new Honeywell temperature sensors with display, CO2 sensor, and temperature adjustment capability.
• Installation of new terminal unit controllers and all required hardware for proper operation and communication of new building automation controls to the City’s existing Building Automation System (BAS).
• Integration of CO2 sensors for demand control ventilation. • Reconnect existing wires to communication system.
• Integration and programming of all new controllers into the City’s existing BAS. • Start-up and testing of the new controls.
Scope of Work Excludes:
• Installation of controls on any equipment not currently controlled by the existing BAS system.
74 Item5.
City of Escondido
Amendment 1 –Attachment A
Power Resiliency / Back Up Power
▪ Provide and install one (1) new permanently connected 150kW backup generator with 1600A automatic transfer switch (ATS) to provide automatic emergency backup power to the building.
The Scope of Work includes:
• Provide and install one (1) new 150kW natural gas generator in the north parking lot between the EVCC and Heritage Academy near the existing switchgear. • Provide and install one (1) new 1600Amp 3-pole automatic transfer switch (ATS). • Provide and install necessary materials to connect the new generator and ATS to the main switchboard.
• Provide concrete pad for the new generator.
• Provide new bollards as required.
• Provide and install new natural gas piping to connect the generator to the existing natural gas service.
• Start-up/testing of the new generator.
• New generator and ATS specifications to be determined upon final engineering design.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications.
Roof Repairs
▪ Repair existing roofing system on EVCC
Scope of Work Includes:
• Patch holes on TPO roofing membrane.
• Replace missing shingles on parapet walls.
• Seal as needed.
Scope of Work Excludes:
• Any major structural repairs.
• Asbestos and/or lead abatement.
• Roof replacement
Fire Station 1
Lighting
▪ Retrofit identified interior T8, CFL, incandescent, HID, and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
75 Item5.
City of Escondido
Amendment 1 –Attachment A
▪ Retrofit identified exterior building and pole mounted T8, CFL, incandescent, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Mechanical
▪ Replace eight (8) existing packaged gas / electric units with new high efficiency packaged heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Curb modifications, rigging, setting new units onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• What about existing gas lines? This comment is for all gas heating systems being replaced with heat pump units.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
Fire Station 2
Lighting
▪ Retrofit identified interior T8, CFL, incandescent, and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building and pole mounted T8, CFL, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. 76 Item5.
City of Escondido
Amendment 1 –Attachment A
Mechanical
▪ Replace four (4) split-system furnaces with new high efficiency split-system heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
▪ Replace one (1) split-system heat pump with new high efficiency unit of similar size and capacity of previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
77 Item5.
City of Escondido
Amendment 1 –Attachment A
Fire Station 3
Lighting
▪ Retrofit identified interior T8, CFL, HID, and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building and pole mounted T8, CFL, HID, and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Mechanical
▪ Replace five (5) existing packaged gas / electric units with new high efficiency packaged heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Curb modifications, rigging, setting new units onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
Fire Station 4
Lighting
▪ Retrofit identified interior T8 and CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
78 Item5.
City of Escondido
Amendment 1 –Attachment A
▪ Retrofit identified exterior building and pole mounted T8, CFL, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Fire Station 5
Lighting
▪ Retrofit identified interior T8 and CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building and pole mounted T8, CFL, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Mechanical
▪ Replace three (3) split-system furnaces with new high efficiency split-system heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
▪ Replace one (1) split-system heat pump with new high efficiency unit of similar size and capacity of previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
79 Item5.
City of Escondido
Amendment 1 –Attachment A
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
Fire Station 6
Lighting
▪ Retrofit identified interior T8, CFL, incandescent, and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building and pole mounted T8, CFL, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Mechanical
▪ Replace four (4) existing packaged gas / electric units with new high efficiency packaged heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Curb modifications, rigging, setting new units onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
80 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
Fire Station 7
Lighting
▪ Retrofit identified interior T8 and CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building and pole mounted T8, CFL, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Mechanical
▪ Replace five (5) packaged gas / electric units with new high efficiency packaged heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Curb modifications, rigging, setting new units onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
81 Item5.
City of Escondido
Amendment 1 –Attachment A
Grape Day Park
Lighting
▪ Retrofit identified exterior pole mounted HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Grape Day Park Historical Sites
Controls
▪ Provide and install four (4) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Mechanical
▪ Replace one (1) split-system furnace with new high efficiency split-system heat pump unit of similar size and capacity of previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network. 82 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
Grove Park
EV Charging
▪ Provide and install two (2) dual-port and one (1) single-port Level 2 EV charging stations at Grove Park for public use. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed in east parking lot located off Ash St. • Provide and install two (2) dual-port and one (1) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install three (3) concrete bases to support the EV pedestals. • Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Jesmond Dene Park
EV Charging
▪ Provide and install two (2) dual-port and one (1) single-port Level 2 EV charging stations at Jesmond Dene Park for public use. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed in the northeast parking lot located near the baseball fields. • Provide and install two (2) dual-port and one (1) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
83 Item5.
City of Escondido
Amendment 1 –Attachment A
• Install three (3) concrete bases to support the EV pedestals. • Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Lighting
▪ Retrofit identified interior T8 and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building mounted T8 and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
James Stone Pool
Renewables
▪ Provide and install a new 46.9 kWDC solar PV carport system in the parking lot adjacent to the central plant between Woodward Ave. & N. Escondido Blvd. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s).
Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection.
Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Installation of solar PV array on structural steel carport over the single row of parking stalls just west, across the right-of-way from James Stone Pool. • Removal, demolition, and haul away of (2) existing exterior light pole and (5) small sized trees that coincide with proposed carport-mounted solar PV system. • Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. 84 Item5.
City of Escondido
Amendment 1 –Attachment A
• Installation of data acquisition system to provide system performance monitoring.
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements, or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Kit Carson Park
Lighting
▪ Retrofit identified interior T8, T12, CFL, and incandescent lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building and pole mounted T8, CFL, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. ▪ Retrofit identified HID sports field lighting systems with new high efficiency LED lighting systems at the Adult Softball Sports Field, Soccer Sports Field, Youth Baseball Sports Field, Youth Softball Sports Field, and Youth Sports Park. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Scope of work includes:
• Remove and dispose of existing HID sports field lighting fixtures. • Installation of the new LED sports field lighting fixtures with instant on capability and step controls onto existing poles.
• Photometric analysis will be provided to the City prior to any material orders to ensure proper coverage of the sport area.
• Proper directional control to prevent light trespass off property. • New control system with web access.
• Required wiring and conduit to connect lighting and controls. • Assumption that existing sports field lighting support poles have been approved by the City for the use of supporting the existing sports field lighting systems. • Reuse of the existing sports field lighting support poles to affix the new lighting system. • Verification that existing field lighting poles will structurally support the new lighting system. • Manufacturer provided training to staff .
• Manufacturer provided 10-year warranty.
Scope of Work Excludes:
• New electrical service or improvements to existing electrical infrastructure. • Any wiring or conduit between poles or panels to poles. 85 Item5.
City of Escondido
Amendment 1 –Attachment A
• New sports field lighting fixture support poles.
• Retroactive city approval / certification of existing sports field lighting poles.
Mechanical
▪ Replace one (1) split-system heat pump with a new high efficiency unit of similar size and capacity of the previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
Controls
▪ Provide and install two (2) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
EV Charging
El Arroyo Restrooms
▪ Provide and install two (2) dual-port and one (1) single-port Level 2 EV charging stations at Kit Carson Park for public use. Final location of charging stations to be determined upon final engineering and ADA review.
86 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work Includes:
• EV chargers will be installed at parking stalls just north of the El Arroyo restrooms. • Provide and install two (2) dual-port and one (1) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install three (3) concrete bases to support the EV pedestals. • Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Sports Center
▪ Provide and install two (2) dual-port and one (1) single-port Level 2 EV charging stations at Kit Carson Park for public use. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed at parking stalls beneath existing western-most solar PV carport at the Sports Center.
• Provide and install two (2) dual-port and one (1) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install three (3) concrete bases to support the EV pedestals. • Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
87 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Tennis Courts
▪ Provide and install two (2) dual-port and one (1) single-port Level 2 EV charging stations at Kit Carson Park for public use. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed at parking stalls just east of the Tennis Courts. • Provide and install two (2) dual-port and one (1) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install three (3) concrete bases to support the EV pedestals. • Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Adult Softball Complex
▪ Provide and install two (2) dual-port and one (1) single-port Level 2 EV charging stations at Kit Carson Park for public use. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed near the Adult Softball Complex. • Provide and install two (2) dual-port and one (1) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install three (3) concrete bases to support the EV pedestals. 88 Item5.
City of Escondido
Amendment 1 –Attachment A
• Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Lake Wohlford Boat House
Lighting
▪ Retrofit identified interior T8 and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building mounted HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Library
Lighting
▪ Retrofit identified exterior building mounted HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Transformers
▪ Replace one (1) existing transformer with new equal capacity high efficiency transformer. The new transformer will be of the same electrical configuration and be placed in the same location and fit within existing constraints as the existing transformer.
The Scope of Work Includes:
• Remove and dispose of existing transformer.
• Installation of new dry type, low loss, high efficiency transformer. • Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
• Compliance with all state, local electric codes.
89 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work Excludes:
• Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
Power Resiliency / Back Up Power
▪ Provide and install one (1) new permanently connected 250kW backup generator with 800A automatic transfer switch (ATS) to provide automatic emergency backup power to the building.
The Scope of Work includes:
• Provide and install one (1) new 250kW natural gas generator in the northeast parking lot near the existing switchgear.
• Provide and install one (1) new 800Amp 3-pole automatic transfer switch (ATS). • Provide and install necessary materials to connect the new generator and ATS to the main switchboard.
• Provide concrete pad for the new generator.
• Provide new bollards as required.
• Provide and install new natural gas piping to connect the generator to the existing natural gas service.
• Start-up/testing of the new generator.
• New generator and ATS specifications to be determined upon final engineering design.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications.
EV Charging
▪ Provide and install two (2) single-port Level 2 EV charging stations at the Library for public use.
Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed in Library parking lot beneath new solar carport. • Provide and install two (2) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install two (2) concrete bases to support the EV pedestals. • Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
90 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Renewables
▪ Provide and install a new 175.0 kWDC solar PV carport system. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s).
Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection.
Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Removal, demolition, and haul away of (2) existing exterior light that coincide with proposed carport-mounted solar PV system.
• Installation of solar PV array on structural steel carports over the single row of existing parking stalls along northern edge of Library parking lot, in addition to a carport over the main island of parking stalls in the center of the parking lot. • Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. • Installation of data acquisition system to provide system performance monitoring.
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements, or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Mathes Center
Lighting
▪ Retrofit identified interior T8 lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
Mechanical
▪ Replace seven (7) packaged gas / electric units with new high efficiency packaged heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
91 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Curb modifications, rigging, setting new units onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
Controls
▪ Provide and install nine (9) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Mayflower Dog Park
Lighting
▪ Retrofit identified exterior pole mounted HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
▪ Retrofit HID field lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. 92 Item5.
City of Escondido
Amendment 1 –Attachment A
Scope of work includes:
• Remove and dispose of existing HID field lighting fixtures. • Installation of the new LED field lighting fixtures with instant on capability and step controls onto existing poles.
• Photometric analysis will be provided to the City prior to any material orders to ensure proper coverage of area.
• Proper directional control to prevent light trespass off property. • New control system with web access
• Required wiring and conduit to connect lighting and controls. • Assumption that existing field lighting support poles have been approved by the City for the use of supporting the existing field lighting systems.
• Reuse of the existing field lighting support poles to affix the new lighting system. • Verification that existing field lighting poles will structurally support the new lighting system. • Manufacturer provided training to staff.
• Manufacturer provided 10-year warranty.
Scope of Work Excludes:
• New electrical service or improvements to existing electrical infrastructure. • Any wiring or conduit between poles or panels to poles. • New field lighting fixture support poles.
• Retroactive city approval / certification of existing field lighting poles.
Mountain View Park
Lighting
▪ Retrofit identified interior T8 lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building and pole mounted HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
▪ Retrofit HID sports field lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Scope of work includes:
• Remove and dispose of existing HID sports field lighting fixtures. • Installation of the new LED field lighting fixtures with instant on capability and step controls onto existing poles.
• Photometric analysis will be provided to the City prior to any material orders to ensure proper coverage of the sport area.
93 Item5.
City of Escondido
Amendment 1 –Attachment A
• Proper directional control to prevent light trespass off property. • New control system with web access.
• Required wiring and conduit to connect lighting and controls. • Assumption that existing sport field lighting support poles have been approved by the City for the use of supporting the existing sports field lighting systems. • Reuse of the existing sports field lighting support poles to affix the new lighting system. • Verification that existing sports field lighting poles will structurally support the new lighting system.
• Manufacturer provided training to staff.
• Manufacturer provided 10-year warranty.
Scope of Work Excludes:
• New electrical service or improvements to existing electrical infrastructure. • Any wiring or conduit between poles or panels to poles. • New sports field lighting fixture support poles.
• Retroactive city approval / certification of existing sports field lighting poles.
Oak Hill Activity Center
Lighting
▪ Retrofit identified interior T8 and CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building mounted CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Mechanical
▪ Replace one (1) mini-split heat pump with new high efficiency unit of similar size and capacity of previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network. 94 Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Any required programming or system upgrades to the existing fire alarm system. ▪ Replace one (1) split-system furnace with new high efficiency unit of similar size and capacity of previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
Controls
▪ Provide and install two (2) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Park Avenue Community Center (PACC) / Veterans Center
Lighting
▪ Retrofit identified interior T8 and CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
95 Item5.
City of Escondido
Amendment 1 –Attachment A
▪ Retrofit identified exterior building and pole mounted T8, CFL, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Power Resiliency / Back Up Power
▪ Provide and install one (1) new permanently connected 130kW backup generator with 600A automatic transfer switch (ATS) to provide automatic emergency backup power to the building.
The Scope of Work includes:
• Provide and install one (1) new 130kW natural gas generator in the center courtyard. • Provide and install one (1) new 600Amp 3-pole automatic transfer switch (ATS). • Provide and install necessary materials to connect the new generator and ATS to the main switchgear.
• Provide concrete pad for the new generator.
• Provide new bollards as required.
• Provide and install new natural gas piping to connect the generator to the existing natural gas service.
• Start-up/testing of the new generator.
• New generator and ATS specifications to be determined upon final engineering design.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications.
Transformers
▪ Replace two (2) existing transformers with new equal capacity high efficiency transformers. The new transformers will be of the same electrical configuration and be placed in the same location and fit within existing constraints as the existing transformers.
The Scope of Work Includes:
• Remove and dispose of existing transformers.
• Installation of new dry type, low loss, high efficiency transformers. • Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
• Compliance with all state, local electric codes.
The Scope of Work Excludes:
• Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
96 Item5.
City of Escondido
Amendment 1 –Attachment A
Roof Recoating
▪ Coat existing built-up flat roof areas of PACC buildings with fluid applied roofing.
Scope of Work Includes:
• Preparation of existing built-up roof to include removal of dirt, debris, and gravel. • Pressure wash built-up roof surfaces to be coated.
• Remove and reinstall counterflashing as needed.
• Seal pipes, vents, and other roof equipment.
• Cut blisters and seal as needed.
• Apply silicone coating per manufacturer’s guidelines to required thickness. • Reseal top of counterflashing as needed.
Scope of Work Excludes:
• Structural repairs.
• Asbestos and/or lead abatement.
EV Charging
▪ Provide and install one (1) dual-port and two (2) single-port Level 2 EV charging stations at the PACC for public use. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed in PACC parking lot beneath the new solar PV carport. • Provide and install one (1) dual-port and two (2) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install three (3) concrete bases to support the EV pedestals. • Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
97 Item5.
City of Escondido
Amendment 1 –Attachment A
Renewables
▪ Provide and install a new 71.3 kWDC carport-mounted solar PV system. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s). Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection.
Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Installation of solar PV array on structural steel carport over the single row of existing parking stalls just north of the PACC facility’s northern entrance, • Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. • Installation of data acquisition system to provide system performance monitoring.
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements, or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Police and Fire Head Quarters.
Lighting
▪ Retrofit identified interior T8, CFL, and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building and pole mounted CFL, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Transformers
▪ Replace two (2) existing transformers with new equal capacity high efficiency transformers. The new transformers will be of the same electrical configuration and be placed in the same location and fit within existing constraints as the existing transformers.
The Scope of Work Includes:
• Remove and dispose of existing transformers.
• Installation of new dry type, low loss, high efficiency transformers. • Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
98 Item5.
City of Escondido
Amendment 1 –Attachment A
• Compliance with all state, local electric codes.
The Scope of Work Excludes:
• Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
Public Works Yard
Mechanical
▪ Replace two (2) split-system heat pumps with new high efficiency units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
▪ Replace one (1) split-system furnace with new high efficiency split-system heat pump unit of similar size and capacity of previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
99 Item5.
City of Escondido
Amendment 1 –Attachment A
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
▪ Replace one (1) wall-mounted heat pump with new high efficiency unit of similar size and capacity of previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
Controls
▪ Provide and install thirteen (13) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Power Resiliency / Back Up Power
▪ Provide and install one (1) new permanently connected 300kW backup generator with 1200A automatic transfer switch (ATS) to provide automatic emergency backup power to the building. 100
Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work includes:
• Provide and install one (1) new 300kW natural gas generator in the center courtyard. • Provide and install one (1) new 1200Amp 3-pole automatic transfer switch (ATS). • Provide and install necessary materials to connect the new generator and ATS to the main switchgear.
• Provide concrete pad for the new generator.
• Provide new bollards as required.
• Provide and install new natural gas piping to connect the generator to the existing natural gas service.
• Start-up/testing of the new generator.
• New generator and ATS specifications to be determined upon final engineering design.
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications.
EV Charging
▪ Provide and install five (5) dual-port Level 2 EV charging stations at the Public Works Yard authorized electric vehicles only. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed in southeast parking lot located off Spruce St. • Provide and install five (5) dual-port EV charging stations. • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install five (5) concrete bases to support the EV pedestals. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen lot or electrical deficiencies up to the current code.
Ranger Station – Dixon Lake
Lighting
▪ Retrofit identified interior T8 and CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, 101
Item5.
City of Escondido
Amendment 1 –Attachment A
quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building mounted T8, CFL, and HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Controls
▪ Provide and install two (2) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Ranger Station – Lake Wohlford
Mechanical
▪ Replace one (1) wall-mounted heat pump with new high efficiency unit of similar size and capacity of previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Curb modifications, rigging, setting new unit onto curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
102
Item5.
City of Escondido
Amendment 1 –Attachment A
Controls
▪ Provide and install one (1) new Wi-Fi smart thermostat w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostat.
• Install new locally mounted Wi-Fi smart thermostat to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Real Estate Property
Mechanical
▪ Replace three (3) packaged gas / electric units with new high efficiency packaged heat pump units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Curb modifications, rigging, setting new units onto roof curb as necessary. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Cap existing gas lines.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
▪ Replace one (1) split-system heat pump unit with new high efficiency unit of similar size and capacity of previous unit. Please refer to the Mechanical Replacement Inventory for equipment size and location.
103
Item5.
City of Escondido
Amendment 1 –Attachment A
The Scope of Work Includes:
• Removal and proper disposal of existing unit.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new unit.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new unit and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Roofing repairs not directly related to the scope of mechanical work. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
Controls
▪ Provide and install seven (7) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Recycling Offices
Lighting
▪ Retrofit identified interior T12, incandescent, and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified exterior building mounted incandescent lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
104
Item5.
City of Escondido
Amendment 1 –Attachment A
Mechanical
▪ Replace two (2) wall-mounted heat pumps with new high efficiency units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing.
Controls
▪ Provide and install two (2) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Transformers
▪ Replace one (1) existing transformer with new equal capacity high efficiency transformer. The new transformer will be of the same electrical configuration and be placed in the same location and fit within existing constraints as the existing transformer.
The Scope of Work Includes:
• Remove and dispose of existing transformer.
• Installation of new dry type, low loss, high efficiency transformer. 105
Item5.
City of Escondido
Amendment 1 –Attachment A
• Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
• Compliance with all state, local electric codes.
The Scope of Work Excludes:
• Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
Reidy Creek Golf Course
Transformers
▪ Replace one (1) existing transformer with new equal capacity high efficiency transformer. The new transformer will be of the same electrical configuration and be placed in the same location and fit within existing constraints as the existing transformer.
The Scope of Work Includes:
• Remove and dispose of existing transformer.
• Installation of new dry type, low loss, high efficiency transformer. • Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
• Compliance with all state, local electric codes.
The Scope of Work Excludes:
• Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
Rod McLeod Park
Lighting
▪ Retrofit identified interior T8 lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified building mounted HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
106
Item5.
City of Escondido
Amendment 1 –Attachment A
Ryan Park
Lighting
▪ Retrofit identified interior T8 and CFL lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations. Occupancy sensors and/or dimming control, if provided, will be identified within the Lighting Summary.
▪ Retrofit identified building and pole mounted HID and LED lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Transformers
▪ Replace one (1) existing transformer with new equal capacity high efficiency transformer. The new transformer will be of the same electrical and be placed in the same location and fit within existing constraints as the existing transformer.
The Scope of Work Includes:
• Remove and dispose of existing transformer.
• Installation of new dry type, low loss, high efficiency transformer. • Disconnect / reconnect primary and secondary feeders. • Proper grounding connections.
• Installation per manufacturer’s guidelines.
• Compliance with all state, local electric codes.
The Scope of Work Excludes:
• Upgrades, repairs, or additional work required to bring undisclosed or unforeseen electrical deficiencies up to current code.
EV Charging
▪ Provide and install two (2) dual-port and one (1) single-port Level 2 EV charging stations at Ryan Park for public use. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed in the east parking lot near the restrooms. • Provide and install two (2) dual-port and one (1) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install three (3) concrete bases to support the EV pedestals. • Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. 107
Item5.
City of Escondido
Amendment 1 –Attachment A
• Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Vineyard Golf Course
Mechanical
▪ Replace two (2) split-system heat pumps with new high efficiency units of similar size and capacity of previous units. Please refer to the Mechanical Replacement Inventory for equipment size and location.
The Scope of Work Includes:
• Removal and proper disposal of existing units.
• Proper containment and disposal of refrigerant per EPA guidelines. • Installation of new units.
• Flush and reconnect existing line set and pressure test. • Disconnection/reconnection of the existing electrical service. • Installation of new electrical disconnects.
• Condensate connections.
• Start-up/testing of the new units and connection to the new Wi-Fi smart thermostat network.
The Scope of Work Excludes:
• Undisclosed electrical and structural upgrades/modifications. • Any required programming or system upgrades to the existing fire alarm system. • Duct repair and air balancing
Controls
▪ Provide and install three (3) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
108
Item5.
City of Escondido
Amendment 1 –Attachment A
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
Washington Park
Lighting
▪ Retrofit identified exterior pole mounted HID lighting systems with new high efficiency LED lighting systems. Please see the Lighting Summary in Attachment B for information on lighting scope, quantities, and locations.
Controls
▪ Provide and install two (2) new Wi-Fi smart thermostats w/ CO2 monitoring.
The Scope of Work includes:
• Disconnect and remove the existing thermostats.
• Install new locally mounted Wi-Fi smart thermostats to allow for local control and override capabilities within a pre-programmed range.
• Programming and checkout.
The Scope of Work excludes:
• Any required upgrades or improvements to the existing network. • Controls for existing evaporative cooling units, heating only units, ductless split system units, and window AC units.
EV Charging
▪ Provide and install one (1) dual-port and one (1) single-port Level 2 EV charging stations at Washington Park for public use. Final location of charging stations to be determined upon final engineering and ADA review.
The Scope of Work Includes:
• EV chargers will be installed in Washington Park parking lot beneath the new solar PV carport.
• Provide and install one (1) dual-port and one (1) single-port EV charging station(s). • Provide and install new electrical wiring and components, as necessary, to connect the EV charger to the existing power source.
• Install two (2) concrete bases to support the EV pedestals. 109
Item5.
City of Escondido
Amendment 1 –Attachment A
• Provide ADA stall restripes for (1) Van Accessible ADA accessible EV charging stall. • Provide and install new bollards and/or wheel block and signage, as necessary for each EV parking stall.
• Concrete and/or site repairs to return work affected areas to “as-found” conditions. • Start-up/testing of the new EV charger(s).
The Scope of Work excludes:
• Undisclosed electrical and structural upgrades/modifications. • Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the EV Charger installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
Renewables
▪ Provide and install a new 77.8 kWDC carport-mounted solar PV system. Installation will include necessary engineering, labor, and equipment to connect the new PV system to the existing electrical meter(s). Please refer to Attachment D for additional details on scope, location, system sizing, and point(s) of interconnection.
Scope of work includes:
• Engineering, soil testing, construction, commissioning, and monitoring of the new PV system.
• Removal, demolition, and haul away of (1) existing exterior light pole and (3) small sized trees that coincide with proposed carport-mounted solar PV system. • Installation of solar PV array on structural steel carport over the south-easternmost parking island in the Washington Park parking lot.
• Installation of carport underside lighting.
• Support to execute the utility interconnection agreement. • Installation of data acquisition system to provide system performance monitoring. • Provide ADA stall restripes for stall under proposed solar PV carport and path-of-travel (POT) linkage from said stall to nearest existing ADA POT.
Scope of work excludes:
• Upgrades, repairs, parking lot restriping, ADA improvements (unless mentioned), or additional work not associated with the solar PV Carport installation but required to bring existing undisclosed or unforeseen ADA and/or electrical deficiencies up to the current code.
110
Item5.
City of Escondido
Amendment 1- Attachment B
Attachment “B”
Solar Installation
111
Item5.
City of Escondido
Amendment 1- Attachment B
SYSTEM LOCATION AND DESCRIPTION:
City of Escondido
1. Site Location Central Plant
Meter #1
Central Plant
Meter #2 City Hall Concert Hall Conference Center
2. Point of
Interconnection
Meter #
6584826
Meter #
6701453
Meter #
6697071
Meter #
6688044
Meter #
6577721
3. PV System Size 123.1 kWDC 272.1 kWDC 346.6 kWDC 298.0 kWDC 99.9 kWDC
4. PV Modules
Silfab
SIL-540-XM
or Equal
Silfab
SIL-540-XM
or Equal
Silfab
SIL-540-XM
or Equal
Silfab
SIL-540-XM
or Equal
Silfab
SIL-540-XM
or Equal
5. PV Inverters Solectria PVI
or Equal
Solectria PVI
or Equal
Solectria PVI
or Equal
Solectria PVI
or Equal
Solectria PVI
or Equal
6. PV System
Solar Carport
Structure 13’ 6”
Clear Height
Solar Carport
Structure 13’ 6”
Clear Height
Solar Carport
Structure 13’ 6”
Clear Height
Solar Carport
Structure 13’ 6”
Clear Height
Solar Carport
Structure 13’ 6”
Clear Height
7. EV Chargers N/A
(2) Dual and (1)
Single Port EV
Chargers
80A/Port or Equal
(3) Dual and (2)
Single Port EV
Chargers
80A/Port or
Equal
(1) Dual and (1)
Single Port EV
Chargers
80A/Port or
Equal
City of Escondido
1. Site Location James Stone
Pool Library Museum PACC Theater
2. Point of
Interconnection
Meter #
6507715
Meter #
6839229
Meter #
6584264
Meter #
6693027
Meter #
6694879
3. System Size 46.9 kWDC 175.0 kWDC 162.0 kWDC 71.2 kWDC 136.0 kWdc
4. PV Modules
Silfab
SIL-540-XM
or Equal
Silfab
SIL-540-XM
or Equal
Silfab
SIL-540-XM
or Equal
Silfab
SIL-540-XM
or Equal
Silfab
SIL-540-XM
or Equal
5. Inverters Solectria PVI
or Equal
Solectria PVI
or Equal
Solectria PVI
or Equal
Solectria PVI
or Equal
Solectria PVI
or Equal
6. System
Solar Carport
Structure 13’ 6”
Clear Height
Solar Carport
Structure 13’ 6”
Clear Height
Solar Carport
Structure 13’
6” Clear
Height
Solar Carport
Structure 13’ 6”
Clear Height
Solar Carport
Structure 13’ 6”
Clear Height
7. EV Chargers N/A
(2) Single Port EV
Chargers
80A/Port or Equal
N/A
(1) Dual and (2)
Single Port EV
Chargers
80A/Port or
Equal
N/A
The information presented in the table above is subject to adjustment depending on final design and sitting.
Siting locations are dependent on final survey results for underground utilities and easements. 112
Item5.
City of Escondido
Amendment 1- Attachment B
SYSTEM LOCATION AND DESCRIPTION (Continued):
City of Escondido
1. Site Location Washington
Park
Francis Ryan
Park Grove Park Jesmond Dene Park
Kit Carson Park
Adult Softball
2. Point of
Interconnection
Meter #
6583033
Meter #
6584404
Meter #
6487625
Meter #
6769031
Meter #
6807524
3. System Size 77.8 kWdc
N/A
4. PV Modules
Silfab
SIL-540-XM
or Equal
5. Inverters Solectria PVI
or Equal
6. System
Solar Carport
Structure 13’ 6”
Clear Height
7. EV Chargers
(1) Dual and (1)
Single Port EV
Chargers
50A/Port or
Equal
(2) Dual and (1)
Single Port EV
Chargers
50A/Port or
Equal
(2) Dual and (1)
Single Port EV
Chargers
50A/Port or
Equal
(2) Dual and (1)
Single Port EV
Chargers
50A/Port or Equal
(2) Dual and (1) Single
Port EV Chargers
50A/Port or Equal
City of Escondido
1. Site Location Kit Carson Park
Arroyo RR
Kit Carson Park
Sports Center
Kit Carson Park
Tennis Courts
Public Works
Yard
2. Point of
Interconnection
Meter #
6622779
Meter #
6700938
Meter #
6576493
Meter #
6849869
3. EV Chargers
(2) Dual and (1) Single
Port EV Chargers
50A/Port or Equal
(2) Dual and (1) Single
Port EV Chargers
50A/Port or Equal
(2) Dual and (1) Single
Port EV Chargers
50A/Port or Equal
(5) Dual Port EV
Chargers
80A/Port or Equal
The information presented in the table above is subject to adjustment depending on final design and siting.
Siting locations are dependent on the final survey results for underground utilities and easements. 113
Item5.
City of Escondido
Amendment 1- Attachment B
1. Permits and Regulatory Fees
An allowance for building, fire and electrical permits only is included for $291,172.00. This amount includes City permitting, fire review, and utility application fees for all sites. All other permits/approvals are excluded.
Climatec LLC includes durations of 16 weeks for procuring permits and regulatory approvals. Climatec LLC will not be responsible for construction delays caused by permit and approval requirements from local jurisdictions or regulatory review bodies. Any delays in procuring permits will entitle Climatec LLC a time extension change order to the Contract as a day for day extension to our plan for obtaining required permits and/or approvals, as defined above or in the project schedule.
2. Utility Requirements
The solar and EV Charger scope assumes all utility-owned electrical equipment serving the sites electrical distribution system has adequate capacity to handle the photovoltaic system output. No utility required electrical equipment upgrade or replacement is included in this scope, including design and coordination thereof.
Any costs associated with unforeseen utility interconnection requirements, including but not limited to utility-owned equipment upgrades or additions, relay protection equipment external to the inverters, system impact studies, or telemetry requirements and interconnection studies are not included in this scope.
3. Facility Equipment
The existing panels are assumed to have provisions to accept cable connections on the primary side of the main service breaker, or adequate space and capacity for a new breaker. Panel or bus bar reconfiguration and/or City distribution equipment re- listing certification is not included.
Contract excludes Short-Circuit Coordination Study for this project. Climatec LLC will provide overcurrent settings that will be coordinated with City overcurrent settings.
The solar and EV Charger scope assumes current switchboards / panelboards meet all code requirements.
Solar system includes all standard interconnection related equipment on the City side of the meter, including panel circuit breakers, utility, and/or visible utility lockable disconnect switches, solarmetering, conduit, and wiring. Additionalprotectionor upgrades required by the utilities above that provided by the certified inverters is not included.
4. Shading
The solar and EV charger scope design is based on existing visual conditions on site. Removal of trees or other obstructions to install the solar arrays and system components is included in this scope. Trees and/or other obstructions subsequently identified for removal or trimming by the City must be removed or trimmed, or performance expectations/guarantees will require adjustment.
5. Commissioning
The solar and EV charger scope assumes commissioning requirementsfor the solar and EV charger scope only.
6. Monitoring
Solar monitoring will be accomplished via cell card. Energy Management System Integration or similar control or SCADA system integrations to the new photovoltaic array(s) is excluded. All other communication and low voltage infrastructure is excluded.
7. Site Embedding Conditions Assumed
A normal embedded depth of 11 feet is assumed. If additional width, embedded depth or spread footing is needed due to soil conditions, additional costs will be the responsibility of the client. 114
Item5.
City of Escondido
Amendment 1- Attachment B
8. Storage
City shall provide Climatec LLC with an area for storage space located near the site for storage of materials, tools and equipment, and other purposes.
9. Exclusions
ADA.
Scope excludes modification requirements for accessibility upgrades and accessibility design around the photovoltaic parking canopy structures (unless otherwise mentioned in scope document). Assumes that the current parking lot layout has been reviewed and approved by the Authority Having Jurisdiction (AHJ). If the architect of record recommends addition of new accessible parking stalls under the solar canopies, changed path of travel and/or new canopies over existing accessible stalls, design and construction costs will be addressed via Change Order.
Irrigation.
Irrigation reconfiguration if necessary to complete any foundation construction is not included.
Fire.
Fire hydrant flow tests or installation of a new fire hydrant are not included. 115
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Central Plant Meter #1 | Solar: 123.1 kWDC
116
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Central Plant Meter #2 | Solar: 272.1 kWDC
117
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
City Hall | Solar: 346.6 kWDC | Level 2 EV Chargers (80A/Port) - (1) Single Port & (2) Dual Port 118
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Concert Hall | Solar: 298.0 kWDC | Level 2 EV Chargers (80A/Port) - (2) Single Port & (3) Dual Port 119
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Conference Center | Solar: 99.9 kWDC | Level 2 EV Chargers (80A/Port) - (1) Single Port & (1) Dual Port 120
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
James Stone Pool | Solar: 46.9 kWDC
121
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Library | Solar: 175.0 kWDC | Level 2 EV Chargers (80A/Port) - (2) Single Port 122
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Museum | Solar: 162.0 kWDC
123
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
PACC | Solar: 71.2 kWDC | Level 2 EV Chargers (80A/Port) - (2) Single Port & (1) Dual Port 124
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Theater | Solar: 136.0 kWDC
125
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Washington Park | Solar: 77.8 kWDC | Level 2 EV Chargers (80A/Port) - (1) Single Port & (1) Dual Port 126
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Francis Ryan Park | Level 2 EV Chargers (50A/Port) - (1) Single Port & (2) Dual Port 127
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Grove Park | Level 2 EV Chargers (50A/Port) - (1) Single Port & (2) Dual Port 128
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Jesmond Dene Park | Level 2 EV Chargers (50A/Port) - (1) Single Port & (2) Dual Port 129
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Kit Carson Park – Adult Softball | Level 2 EV Chargers (50A/Port) - (1) Single Port & (2) Dual Port 130
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Kit Carson Park – Arroyo RR | Level 2 EV Chargers (50A/Port) - (1) Single Port & (2) Dual Port 131
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Kit Carson Park – Sports Center | Level 2 EV Chargers (50A/Port) - (1) Single Port & (2) Dual Port 132
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Kit Carson Park – Tennis Courts | Level 2 EV Chargers (50A/Port) - (1) Single Port & (2) Dual Port 133
Item5.
City of Escondido
Amendment 1- Attachment B
CITY OF ESCONDIDO
Public Works Yard | Level 2 EV Chargers (80A/Port) - (5) Dual Port 134
Item5.
City of Escondido
Amendment 1- Attachment D
Attachment "C”
Lighting Summary
135
Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
City Hall & CCAE -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Center Theater
1st Floor
1x4x 2L sm strip, F32T8 32w, electronic 18 18
ballast
Rf#-36 Rm - Back Stage RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-37 Rm - Loading
Dock
RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
MH 1L pm high bay, MH 400W, HID 4 4
ballast
Rf#-38 Rm - Scene Shop NL150/hb/s - New LED area interior high bay, 75,000-Hr L70 rated life, lens, 120w, dimming capable (ALE) oemB
Rf#-39 Rm - Terrace CF 2L wm square, CFP-13W, CF ballast 5 5 Walk
RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated life, remove ballast from service
1x4 1L Strip, F32T8 32w, electronic 4 4
ballast
Rf#-40 Rm - T201
Engineering
RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 1L wm rec step light, CFP-5w TT 6 6
2700K, CF ballast
Rf#-41 Rm - South Stairs RL061/h/sk - (1) LED 2 pin lamp, direct wire, Gx23 base, 120/277v, 6w, 50,000-Hr L70 rated life, (1) new lamp socket
Rf#-42 Rm - Ext - Wall CF 2L wm square, CFP-13W, CF ballast 5 5 Mount
RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated life, remove ballast from service
Rf#-43 Rm - Walkway CF 1L socket, CFP-26w, CF ballast 20 20 Niche
RL0111/h/sk - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal, (1) new lamp holder
Rf#-44 Rm - Walkway CF 1L socket pm E26, CFS-15w, CF ballast 3 RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K 3 2nd Floor
1x4x 2L rec trf, F32T8 32w, electronic 12 12
ballast
Rf#-45 Rm - WRR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-46 Rm - Ext Terrace CF 2L wm square, CFP-13W, CF ballast 6 RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated 6 life, remove ballast from service
1x4 1L Strip, F32T8 32w, electronic 2 2
ballast
Rf#-47 Rm - Newhall RR RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Level B
1x4x 1L sm strip (cove), F32T8 32w, 8 8
electronic ballast
Rf#-31 Rm - Lobby RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4 1L Strip, F32T8 32w, electronic 8 8
ballast
Rf#-32 Rm - MRR RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4 1L Strip, F32T8 32w, electronic 8 8
ballast
Rf#-33 Rm - WRR RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 1L sm strip (cove), F32T8 32w, 4 4
electronic ballast
Rf#-34 Rm - Office Mgr RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-35 Rm - Elevator
Lobby
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Building/Area: Central Plant
1st Floor
1x4x 2L sm ind hood, FP54T5 HO 54w, 8 8
electronic ballast HO
Rf#-86 Rm - Boiler RLT542Hdw - (2) 4' LED T5HO lamp 25w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
MH 1L wm wall pack, MH 100W, HID 5 5
ballast
Rf#-87 Rm - Ext - Wall
Mount
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
Building/Area: City Hall
1st Floor
Rf#-1 Rm - Buidling CF 3L pm fxt, CFP-13W 2 pin, CF ballast 12 12 Office
RL063/h - (1) LED 2 pin lamp, direct wire, Gx23 base, 120/277v, 6w, 50,000-Hr L70 rated life
Rf#-2 Rm - Back Hall CF 3L pm fxt, CFP-13W 2 pin, CF ballast 16 RL063/h - (1) LED 2 pin lamp, direct wire, Gx23 base, 120/277v, 6w, 16 50,000-Hr L70 rated life
Rf#-3 Rm - Engineer Hall CF 3L pm fxt, CFP-13W 2 pin, CF ballast 18 RL063/h - (1) LED 2 pin lamp, direct wire, Gx23 base, 120/277v, 6w, 18 50,000-Hr L70 rated life
Rf#-4 Rm - South Hall CF 3L pm fxt, CFP-13W 2 pin, CF ballast 24 RL063/h - (1) LED 2 pin lamp, direct wire, Gx23 base, 120/277v, 6w, 24 50,000-Hr L70 rated life
Rf#-5 Rm - North Hall CF 3L pm fxt, CFP-13W 2 pin, CF ballast 20 RL063/h - (1) LED 2 pin lamp, direct wire, Gx23 base, 120/277v, 6w, 20 50,000-Hr L70 rated life
CF 1L wm wall pack small, CFP-42w, CF 6 6
ballast
Rf#-7 Rm - Ext - Wall
Mount
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
MV 1L wm wall pack large, MV 175W, 1 1
HID ballast
Rf#-8 Rm - Ext - Wall
Mount
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control City Hall & CCAE Lighting Page 1 136 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
City Hall & CCAE -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-9 Rm - Ext - Wall LED 1L fxt various (100+), LED, n/a 0 Mount
DND - DND: (do not do, fixtures left as is)
Rf#-10 Rm - All Areas LED 2L rec can 8", LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 1x4x 1L sm strip (cove), F32T8 32w, 8 8
electronic ballast
Rf#-11 Rm - Ext - Small
Rotunda
RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-12 Rm - Ext - Large MH 1L uplights, MH 400w, HID ballast 8 8 Dome
NL100/PM/sc/s - New LED decorative lighting, pendant mounted, 100w, indirect/direct, 50,000-Hr L70 rated life oemB
2nd Floor
Rf#-6 Rm - North CF 3L pm fxt, CFP-13W 2 pin, CF ballast 30 30 Section
RL063/h - (1) LED 2 pin lamp, direct wire, Gx23 base, 120/277v, 6w, 50,000-Hr L70 rated life
Building/Area: Concert Hall
1st Floor
2x4x 3L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-62 Rm - Roll Up
Door
RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4 1L Strip, F32T8 32w, electronic 2 2
ballast
Rf#-63 Rm - Back Bar RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-64 Rm - Security RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-65 Rm - MRR RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-66 Rm - WRR RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-67 Rm - Back Stage DND (do not do, left as is), n/a, n/a DND - DND: (do not do, fixtures left as is) 0 Level B
1x4 1L Strip, F32T8 32w, electronic 18 18
ballast
Rf#-54 Rm - Lobby Cove RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 1L sm strip, F25T8 25w, electronic 24 24
ballast
Rf#-55 Rm - WRR RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 1L sm strip, F25T8 25w, electronic 14 14
ballast
Rf#-56 Rm - MRR RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-57 Rm - MRR LED 2L rec can 8", LED, n/a 5 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 5 L70 rated life, (1) 8" trim ring extender
Rf#-58 Rm - MRR CF 2L rec can 8", CFP-26w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
1x4 1L Strip, F32T8 32w, electronic 1 1
ballast
Rf#-59 Rm - Stairs RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-60 Rm - House Mgr RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-61 Rm - Usher RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Lower B
1x4 1L Strip, F32T8 32w, electronic 14 14
ballast
Rf#-48 Rm - Trap Pig RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec trf, FB31T8 32w U6, 2 2
electronic ballast
Rf#-49 Rm - Elevator
Lobby
RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) 1x4 1L Strip, F32T8 32w, electronic 2 2
ballast
Rf#-50 Rm - Ext -
Loading
RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4 1L Strip, F32T8 32w, electronic 4 4
ballast
Rf#-51 Rm - Main
Storage
RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 4L pm high bay, FP54T5 HO 54w, 5 5
electronic ballast HO
Rf#-52 Rm - Main
Storage
RLT544Hdw - (4) 4' LED T5HO lamp 25w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-53 Rm - WiFi RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Building/Area: Conference Center
1st Floor
1x4 1L Strip, F32T8 32w, electronic 6 6
ballast
Rf#-13 Rm - Staff MRR RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4 1L Strip, F32T8 32w, electronic 12 12
ballast
Rf#-14 Rm - Staff WRR RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control City Hall & CCAE Lighting Page 2 137 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
City Hall & CCAE -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
1x4x 2L sm ind hood, F32T8 32w, 3 3
electronic ballast
Rf#-15 Rm - Kitchen
Storge
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-16 Rm - Kitchen RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 6 6
ballast
Rf#-17 Rm - Back Hall RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-18 Rm - Back Hall 2x4x 3L rec trf, LED, n/a 6 RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 6 rated life, remove existing ballast from service
1x4x 2L sm ind hood, F32T8 32w, 2 2
electronic ballast
Rf#-19 Rm - Cooler
Lobby
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-20 Rm - Data RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-21 Rm - Data 2x4x 3L rec trf, LED, n/a 1 RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 1 rated life, remove existing ballast from service
1x4x 2L sm ind hood, F32T8 32w, 1 1
electronic ballast
Rf#-22 Rm - Drinks
Storage
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 6 6
ballast
Rf#-23 Rm - Lobby
Storage
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L pm fxt, F32T8 32w, electronic 3 3
ballast
Rf#-24 Rm - Back Bar RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 1L wm rec step light, CFP-5w TT 11 11
2700K, CF ballast
Rf#-27 Rm - Ext - Wall
Mount
RL061/h/sk - (1) LED 2 pin lamp, direct wire, Gx23 base, 120/277v, 6w, 50,000-Hr L70 rated life, (1) new lamp socket
Rf#-28 Rm - Ext - Wall LED 1L rec step light, LED, n/a 30 30 Mount
DND - DND: (do not do, fixtures left as is)
Rf#-29 Rm - Ext - Wall CF 2L wm square, CFP-13W, CF ballast 35 35 Mount
RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated life, remove ballast from service
Rf#-30 Rm - Ext - LED 1L uplight for trees, LED ?w, n/a 0 Ground Mount
DND - DND: (do not do, fixtures left as is)
2nd Floor
1x4x 2L sm ind hood, F32T8 32w, 10 10
electronic ballast
Rf#-25 Rm - Engineer
CC201
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 1L sm strip (cove), F32T8 32w, 24 24
electronic ballast
Rf#-26 Rm - Escondido
Room
RLT842dwDm - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service L-DS Building/Area: Museum
1st Floor
2x2x 2L rec trf, FB31T8 32w U3, 4 4
electronic ballast
Rf#-68 Rm - Store RLT823Udw - (3) 2' LED T8 "U3" lamp 15w, Type B, direct wire, 50,000- Hr L70 rated life, remove existing ballast from service (SYL) 2x2x 2L rec trf, FB31T8 32w U3, 3 3
electronic ballast
Rf#-69 Rm - RR Lobby RLT823Udw - (3) 2' LED T8 "U3" lamp 15w, Type B, direct wire, 50,000- Hr L70 rated life, remove existing ballast from service (SYL) 2x2x 2L rec trf, FB31T8 32w U3, 24 24
electronic ballast
Rf#-70 Rm - Offices RLT823Udw - (3) 2' LED T8 "U3" lamp 15w, Type B, direct wire, 50,000- Hr L70 rated life, remove existing ballast from service (SYL) 1x4x 2L sm ind hood, F32T8 32w, 12 12
electronic ballast
Rf#-71 Rm - Register
Storage
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-72 Rm - Hall RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm ind hood, F32T8 32w, 12 12
electronic ballast
Rf#-73 Rm - Preparation RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4 1L Strip, F32T8 32w, electronic 1 1
ballast
Rf#-74 Rm - Storage RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm ind hood, F32T8 32w, 6 6
electronic ballast
Rf#-75 Rm - Loading
Dock
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4 1L Strip, F32T8 32w, electronic 8 8
ballast
Rf#-76 Rm - Crate
Storage
RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 1L wm jelly jar, CFP-13W 2 pin, CF 8 8
ballast
Rf#-77 Rm - Ext - Wall
Mount
RL091/s/sk - (1) LED 8.5w A19 screw in lamp, 4000K, (1) new lamp socket Building/Area: Studio
1st Floor
Rf#-78 Rm - Walkway CF 1L socket, CFP-26w, CF ballast 12 12 Niche
RL0111/h/sk - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal, (1) new lamp holder
1x4x 2L sm vapor tight, F32T8 32w, 7 7
electronic ballast
Rf#-79 Rm - Walkway RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control City Hall & CCAE Lighting Page 3 138 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
City Hall & CCAE -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-80 Rm - Walkway CF 1L sm sqaure 12", CFP-13W, CF ballast 12 RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated 12 life, remove ballast from service
1x4 1L Strip, F32T8 32w, electronic 12 12
ballast
Rf#-81 Rm - Walkway RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-82 Rm - Walkway LED 1L rec step light, LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 1x4 1L Strip, F32T8 32w, electronic 4 4
ballast
Rf#-83 Rm - MRR RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-84 Rm - MRR CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4 1L Strip, F32T8 32w, electronic 4 4
ballast
Rf#-85 Rm - WRR RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Qty for City Hall & CCAE : 678 678
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control City Hall & CCAE Lighting Page 4 139 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Daley Ranch Maintenance Facility -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: All Buildings
1st Floor
1x4x 2L sm wp, F32T8 32w, electronic 8 8
ballast
Rf#-1 Rm - Garage RLT842dw(h) - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-2 Rm - All Other DND (do not do, left as is), LED ?w, n/a 0 interior Space
DND - DND: (do not do, fixtures left as is)
Rf#-3 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Qty for Daley Ranch Maintenance Facility : 8 8
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Daley Ranch Maintenance Facility Lighting Page 5 140 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
East Valley Community Center ("EVCC") / Heritage Academy - (sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main
1st Floor
Rf#-1 Rm - Lobby CF 2L rec can 8", CFP-26w, CF ballast 33 RL011/ckit/6t8e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 33 L70 rated life, (1) 8" trim ring extender
Rf#-2 Rm - Lobby CF 2L rec can 8", CFP-26w, CF ballast 19 RL011/ckit/6t8e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 19 L70 rated life, (1) 8" trim ring extender
Rf#-3 Rm - Tiny Tots CF 2L rec can 8", CFP-26w, CF ballast 3 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 3 L70 rated life, (1) 8" trim ring extender
Rf#-4 Rm - Tiny Tots CF 2L rec can 8" emr, CFP-26w, CF ballast 3 RL011/ckit/6t8e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 3 L70 rated life, (1) 8" trim ring extender
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-5 Rm - Tiny Tots RLT823dwe - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-6 Rm - Tiny Tots RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-7 Rm - Dance RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-8 Rm - Dance RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-9 Rm - MRR CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
Rf#-10 Rm - WRR CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
Rf#-11 Rm - Grove CF 2L rec can 8", CFP-26w, CF ballast 4 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 4 L70 rated life, (1) 8" trim ring extender
2x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-12 Rm - Grove RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-13 Rm - Main Hall CF 2L rec can 8", CFP-26w, CF ballast 4 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 4 L70 rated life, (1) 8" trim ring extender
2x2x 3L rec trf, F17T8 17w, electronic 6 6
ballast
Rf#-14 Rm - Main Hall RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-15 Rm - Vineyard CF 2L rec can 8", CFP-26w, CF ballast 4 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 4 L70 rated life, (1) 8" trim ring extender
2x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-16 Rm - Vineyard RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-17 Rm - South Hall CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
2x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-18 Rm - South Hall RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-19 Rm - Citrus CF 2L rec can 8", CFP-26w, CF ballast 4 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 4 L70 rated life, (1) 8" trim ring extender
2x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-20 Rm - Citrus RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-21 Rm - Gym CF 2L rec can 8", CFP-26w, CF ballast 3 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 3 L70 rated life, (1) 8" trim ring extender
Rf#-22 Rm - Gym LED 4L pm high bay, LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 Rf#-23 Rm - WRR CF 2L rec can 8", CFP-26w, CF ballast 5 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 5 L70 rated life, (1) 8" trim ring extender
Rf#-24 Rm - WRR CF 2L rec can 8" emr, CFP-26w, CF ballast 2 RL011/ckit/6t8e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
Rf#-25 Rm - MRR CF 2L rec can 8", CFP-26w, CF ballast 4 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 4 L70 rated life, (1) 8" trim ring extender
Rf#-26 Rm - MRR CF 2L rec can 8" emr, CFP-26w, CF ballast 3 RL011/ckit/6t8e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 3 L70 rated life, (1) 8" trim ring extender
CF 2L wm wall pack small, CFP-26w, CF 2 2
ballast
Rf#-27 Rm - Ext - Ceiling
Mount
NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) Rf#-28 Rm - Ext - Ceiling HPS 1L rec square, HPS 70W, HID ballast 6 6 Mount
NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) Rf#-29 Rm - Ext - Wall CF 2L rec can 8", CFP-26w, CF ballast 3 3 Mount
RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 8" trim ring extender
or East Valley Community Center ("EVCC") / Heritage Academy : 129 129 W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control East Valley Community Center ("EVCC") / Heritage Academy Lighting Page 6 141 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 1 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Fire Tower
All
1x4x 2L sm vapor tight (missing lens), 27 27
F32T8 32w, electronic ballast
Rf#-164 Rm - Various
Spaces
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-165 Rm - Starwell HPS 1L wm vandal, HPS 70w, HID ballast 5 NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, 5 built in 120/277v photo cell (Rb)
Roof Line
HPS 1L flood, trunion, HPS 400w, HID 6 6
ballast
Rf#-166 Rm - Ext - Wall
Mount
NL100/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 100w (Vly) oemB
Building/Area: Garage Bay Bldg
1st Floor
Rf#-155 Rm - Garage 1x4x 2L pm strip, TLED, electronic ballast 35 35 Bays
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L pm strip emr, F32T8 32w, 5 5
electronic ballast
Rf#-156 Rm - Garage
Bays
RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-157 Rm - Mezzanine CF 1L wm tear drop , CFP-26w, CF ballast 8 RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 8 rated life, horizontal
CF 1L wm wall pack small emr, CFP-32w, 1 1
CF ballast
Rf#-158 Rm - Ext - Wall
Mount
RL0111/he - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
Rf#-159 Rm - Ext - Wall LPS 2L wm shoe box, LPS 90w, HID ballast 2 2 Mount
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Building/Area: Generator Bldg
1st Floor
1x4x 2L sm fxt, F32T8 32w, electronic 6 6
ballast
Rf#-160 Rm - generator
room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm fxt, F32T8 32w, electronic 1 1
ballast
Rf#-161 Rm - ? Room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm box, F32T8 32w, electronic 2 2
ballast
Rf#-162 Rm - ? Room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 1L wm wall pack small, CFP-32w, CF 16 16
ballast
Rf#-163 Rm - Ext - Wall
Mount
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
Building/Area: Main Bldg
1st Floor
Rf#-1 Rm - Main entry CF 2L rec can ?", CFP-26w, CF ballast 5 5 lobby
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
2x2x 3L rec trf, F17T8 17w, electronic 7 7
ballast
Rf#-2 Rm - Main entry
lobby
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, LEDT8 Type A/B, 2 2
electronic ballast
Rf#-3 Rm - Main entry
lobby
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-4 Rm - museum CF 2L rec can ?", CFP-32w, CF ballast 11 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 11 rated life
MH 1L wm wall pack FCO, MH 100w, HID 4 4
ballast
Rf#-5 Rm - museum RL0341/s/sk - (1) LED 34w A21 style screw in lamp, 120/277, 50,000-Hr rated life, 5000K, mogul base, (1) new lamp socket
CF 8L pm indirect dome, Biax 40w, CF 8 8
ballast
Rf#-6 Rm - museum RL017/bx8 - (8) LED BIAX PL-L lamp, direct wire (remove old ballast), 120/277v, 15w, 50,000-Hr L70 rated life
2x2x 2L rec vol trf, F17T8 17w, electronic 12 12
ballast
Rf#-7 Rm - Bullpen desk
area
RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
Rf#-8 Rm - Lobby RR CF 1L rec can ?", CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
Rf#-9 Rm - Lobby RR CF 1L rec can ?" emr, CFP-26w, CF ballast 1 RL011/ckit/6e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life
1x3x 2L sm strip (cove), F25T8 25w, 5 5
electronic ballast
Rf#-10 Rm - Lobby RR RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-11 Rm - water
heater room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-12 Rm - training CF 1L rec can ?", CFP-26w, CF ballast 12 12 room
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
2x2x 2L rec vol trf, F17T8 17w, electronic 12 12
ballast
Rf#-13 Rm - training
room
RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 1 Lighting Page 7 142 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 1 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
2x2x 3L rec trf, F17T8 17w, electronic 9 9
ballast
Rf#-14 Rm - back
hallway
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, LEDT8 Type A/B, 3 3
electronic ballast
Rf#-15 Rm - back
hallway
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-16 Rm - Conf Room RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-17 Rm - copy room RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-18 Rm - Room to
left of above
RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-19 Rm - T-Shirt
Room
RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-20 Rm - PPE Room RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-21 Rm - Office to
Right of above
RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-22 Rm - Radio Room RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-23 Rm - 911 backup
room
RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-24 Rm - Room next
to above
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-25 Rm - Server
Room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-26 Rm - Office
hallway
RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-27 Rm - Office #1 RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-28 Rm - Office #2 RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-29 Rm - Office #3 RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-30 Rm - Office #4 RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
Rf#-31 Rm - Garage Bays 2x4x 3L rec trf, TLED, electronic ballast DND - DND: (do not do, fixtures left as is) 0 1x4x 2L wm sconce, F32T8 32w, 4 4
electronic ballast
Rf#-32 Rm - Garage Bays RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 1L undercounter, F25T8 25w, 2 2
electronic ballast
Rf#-33 Rm - Garage
Bays counter area
RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-34 Rm - Garage
Bays RR
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-35 Rm - Garage CF 1L rec can ?", CFP-26w, CF ballast 1 1 Bays RR
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-36 Rm - hallway to CF 1L rec can ?", CFP-26w, CF ballast 4 4 back stairs landing
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x3x 1L undercounter, F25T8 25w, 3 3
electronic ballast
Rf#-37 Rm - Counter
area close to above
RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-38 Rm - ? Room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-39 Rm - Back lobby CF 1L rec can ?", CFP-32w, CF ballast 4 4 area by stairs
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-40 Rm - ? Room #1 CF 1L rec can ?", CFP-32w, CF ballast 14 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 14 rated life
Inc. 1L rec can ?" emr, Inc. 1L MR16 35w, 3 3
n/a
Rf#-41 Rm - ? Room #1 RL061/s/mr16 - (1) LED 6w MR16 lamp, 4000K 1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-42 Rm - ? Room #2
in this area
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec vol trf, F17T8 17w, electronic 5 5
ballast
Rf#-43 Rm - kitchen
hallway
RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE)
2x2x 2L rec vol trf emr, F17T8 17w, 1 1
electronic ballast
Rf#-44 Rm - kitchen
hallway
RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE)
Rf#-45 Rm - ? Room CF 1L rec can ?", CFP-26w, CF ballast 1 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 1 rated life
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 1 Lighting Page 8 143 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 1 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-46 Rm - janitor
closet
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 1L rec can, CFP-26w, CF ballast 14 14
dimming
Rf#-47 Rm - TV Room RL011/ckit/6bt - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life L-DS
CF 1L rec can emr, CFP-26w, CF ballast 4 4
dimming
Rf#-48 Rm - TV Room RL011/ckit/6bte - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life L-DS
Rf#-49 Rm - TV Room Inc. 1L rec can, Inc. 1L MR16 35w, n/a 3 RL061/s/mr16 - (1) LED 6w MR16 lamp, 4000K 3 Rf#-50 Rm - dinning CF 1L rec can, CFP-26w, CF ballast 14 14 area
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-51 Rm - dinning CF 1L rec can emr, CFP-26w, CF ballast 3 3 area
RL011/ckit/6e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x3x 1L undercounter, F25T8 25w, 1 1
electronic ballast
Rf#-52 Rm - dinning
area
RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 1L undercounter, F32T8 32w, 1 1
electronic ballast
Rf#-53 Rm - dinning
area
RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec vol trf, F17T8 17w, electronic 9 9
ballast
Rf#-54 Rm - kitchen RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE)
Rf#-55 Rm - kitchen CF 1L rec can, CFP-26w, CF ballast 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
1x3x 1L undercounter, F25T8 25w, 1 1
electronic ballast
Rf#-56 Rm - kitchen RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 1L undercounter, F32T8 32w, 2 2
electronic ballast
Rf#-57 Rm - kitchen RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 2 2
ballast
Rf#-58 Rm - Dorm
Room #1
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 1L undercounter, F25T8 25w, 1 1
electronic ballast
Rf#-59 Rm - Dorm
Room #1
RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-60 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #1
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-61 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 2 2 Room #1 RR
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x3x 2L sm strip (cove), F25T8 25w, 1 1
electronic ballast
Rf#-62 Rm - Dorm
Room #1 RR
RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 2 2
ballast
Rf#-63 Rm - Dorm
Room #2
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 1L undercounter, F25T8 25w, 1 1
electronic ballast
Rf#-64 Rm - Dorm
Room #2
RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-65 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #2
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-66 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 2 2 Room #2 RR
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x3x 2L sm strip (cove), F25T8 25w, 1 1
electronic ballast
Rf#-67 Rm - Dorm
Room #2 RR
RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 2 2
ballast
Rf#-68 Rm - Dorm
Room #1
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 1L undercounter, F25T8 25w, 1 1
electronic ballast
Rf#-69 Rm - Dorm
Room #1
RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-70 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #1
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-71 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 2 2 Room #1 RR
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x3x 2L sm strip (cove), F25T8 25w, 1 1
electronic ballast
Rf#-72 Rm - Dorm
Room #1 RR
RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 2 2
ballast
Rf#-73 Rm - Dorm
Room #4
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 1L undercounter, F25T8 25w, 1 1
electronic ballast
Rf#-74 Rm - Dorm
Room #4
RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-75 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #4
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-76 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 2 2 Room #4 RR
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x3x 2L sm strip (cove), F25T8 25w, 1 1
electronic ballast
Rf#-77 Rm - Dorm
Room #4 RR
RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 1 Lighting Page 9 144 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 1 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-78 Rm - dorm CF 1L rec can, CFP-26w, CF ballast 9 9 hallway
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-79 Rm - All Other DND (do not do, left as is), n/a, n/a 0 interior Space
DND - DND: (do not do, fixtures left as is)
CF 1L wm wall pack small emr, CFP-32w, 10 10
CF ballast
Rf#-80 Rm - Ext - Wall
Mount
RL0111/he - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
CF 1L wm wall pack small, CFP-32w, CF 2 2
ballast
Rf#-81 Rm - Ext - Wall
Mount
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
Rf#-82 Rm - Ext - Wall LPS 2L wm shoe box, LPS 90w, HID ballast 2 2 Mount
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Rf#-83 Rm - Ext - Wall Inc. 1L flood, knuckle, Halogen 300W, n/a 2 2 Mount
NL035/fld - New LED flood, knuckle mount, 50,000-Hr L70 rated life, 35w (Key)
Rf#-84 Rm - Ext - Wall CF 1L wm dome, CFP-32w, CF ballast 2 2 Mount (2nd level)
RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated life, remove ballast from service
1x4x 1L monument, F32T8 32w, 2 2
electronic ballast
Rf#-85 Rm - Ext - Sign RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Inc. 1L ground mount uplight, Inc. 75w 12 12
Par38, n/a
Rf#-86 Rm - Ext - In
Ground
RL091/s/R30 - (1) LED 8w R30 screw in lamp, 4000K
LPS 2L pole mnt hoe box, LPS 90w, HID 14 14
ballast
Rf#-87 Rm - Ext- Pole
Mount
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
2nd Floor
Rf#-88 Rm - stairwell #1 CF 1L rec can, CFP-26w, CF ballast 2 2 (back)
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-89 Rm - Dorm
Room #5
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-90 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #5
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-91 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #5
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-92 Rm - Dorm
Room #6
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-93 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #6
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-94 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #6
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-95 Rm - Dorm
Room #7
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-96 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #7
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-97 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #7
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-98 Rm - Dorm
Room #8
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-99 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #8
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-100 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #8
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-101 Rm - Dorm
Room #9
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-102 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #9
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-103 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #9
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-104 Rm - Dorm
Room #10
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-105 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #10
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-106 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #10
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-107 Rm - Dorm
Room #11
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-108 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #11
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 1 Lighting Page 10 145 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 1 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-109 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #11
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-110 Rm - Dorm
Room #12
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-111 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #12
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-112 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #12
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-113 Rm - Dorm
Room #13
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-114 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #13
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-115 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #13
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-116 Rm - Dorm
Room #14
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-117 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #14
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-118 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #14
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-119 Rm - Dorm
Room #15
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-120 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #15
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-121 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #15
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
1x3x 2L sm strip (cove), F25T8 25w, 2 2
electronic ballast
Rf#-122 Rm - RR #1 RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-123 Rm - RR #1 CF 1L rec can, CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
1x3x 2L sm strip (cove), F25T8 25w, 2 2
electronic ballast
Rf#-124 Rm - RR #2 RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-125 Rm - RR #2 CF 1L rec can, CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
1x3x 2L sm strip (cove), F25T8 25w, 2 2
electronic ballast
Rf#-126 Rm - RR #3 RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-127 Rm - RR #3 CF 1L rec can, CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
1x3x 2L sm strip (cove), F25T8 25w, 2 2
electronic ballast
Rf#-128 Rm - RR #4 RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-129 Rm - RR #4 CF 1L rec can, CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
Rf#-130 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 2 2 hallway
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-131 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 30 30 hallway
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-132 Rm - Dorm CF 1L rec can emr, CFP-26w, CF ballast 14 14 hallway
RL011/ckit/6e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-133 Rm - Dorm CF 1L wm step light, CFP-9w, CF ballast 18 18 hallway
RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated life, remove ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-134 Rm - Dorm
Room #16
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-135 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #16
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-136 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #16
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-137 Rm - Dorm
Room #17
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-138 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #17
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-139 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #17
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-140 Rm - Dorm
Room #18
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 1 Lighting Page 11 146 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 1 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-141 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #18
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-142 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #18
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-143 Rm - Dorm
Room #19
RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-144 Rm - Dorm CF 1L rec can, CFP-26w, CF ballast 1 1 Room #19
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-145 Rm - Dorm CF 1L wm bed light, CFP-26w, CF ballast 1 1 Room #19
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
2x2x 2L rec vol trf, F17T8 17w, electronic 2 2
ballast
Rf#-146 Rm - TV Room RL025/tkit22bt - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-147 Rm - ? Room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 2L sm strip (cove), F25T8 25w, 2 2
electronic ballast
Rf#-148 Rm - RR #5 RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-149 Rm - RR #5 CF 1L rec can, CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
1x3x 2L sm strip (cove), F25T8 25w, 2 2
electronic ballast
Rf#-150 Rm - RR #6 RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-151 Rm - RR #6 CF 1L rec can, CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
1x3x 2L sm strip (cove), F25T8 25w, 2 2
electronic ballast
Rf#-152 Rm - RR #7 RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-153 Rm - RR #7 CF 1L rec can, CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
Rf#-154 Rm - All Other DND (do not do, left as is), n/a, n/a 0 interior Space
DND - DND: (do not do, fixtures left as is)
Qty for Fire Station No. 1 : 599 599
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 1 Lighting Page 12 147 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 2 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main
1st Floor
Rf#-1 Rm - Lobby CF 2L rec can 8", CFP-26w, CF ballast 7 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 7 L70 rated life, (1) 8" trim ring extender
2x4x 3L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-2 Rm - Lobby RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-3 Rm - RR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-4 Rm - Hall CF 2L rec can 8", CFP-26w, CF ballast 15 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 15 L70 rated life, (1) 8" trim ring extender
Rf#-5 Rm - Hall CF 1L rec step light, CFP-13W, CF ballast 7 RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated 7 life, remove ballast from service
1x3x 1L rec trf, F25T8 25w, electronic 1 1
ballast
Rf#-6 Rm - Hall RLT831dw - (1) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-7 Rm - Hall RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-8 Rm - Office RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-9 Rm - Furnace 1x4x 2L rec trf, LED, n/a 3 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 3 rated life, remove existing ballast from service
Rf#-10 Rm - Clothing 1x4x 2L rec trf, LED, n/a 7 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 7 rated life, remove existing ballast from service
Rf#-11 Rm - RR1 CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
Rf#-12 Rm - RR1 1x4x 2L rec trf, LED, n/a 1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 1 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-13 Rm - Sleep 1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-14 Rm - Sleep 2 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-15 Rm - RR2 CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
Rf#-16 Rm - RR2 1x4x 2L rec trf, LED, n/a 1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 1 rated life, remove existing ballast from service
Rf#-17 Rm - Custodian 1x4x 2L rec trf, LED, n/a 1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 1 rated life, remove existing ballast from service
Rf#-18 Rm - Kitchen LED 6L pm fxt large, LED, n/a 2 DND - DND: (do not do, fixtures left as is) 2 Rf#-19 Rm - Kitchen LED 2L sconce small, LED, n/a 4 DND - DND: (do not do, fixtures left as is) 4 Rf#-20 Rm - Kitchen CF 2L rec can 8", CFP-26w, CF ballast 14 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 14 L70 rated life, (1) 8" trim ring extender
2x4x 3L rec trf, F32T8 32w, electronic 8 8
ballast
Rf#-21 Rm - TV RL025/tkit24 - (1) LED 25w 2x4 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
Rf#-22 Rm - Bay North CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 28 28
ballast
Rf#-23 Rm - Bay North RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-24 Rm - Bay South CF 2L rec can 8", CFP-26w, CF ballast 3 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 3 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 42 42
ballast
Rf#-25 Rm - Bay South RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-26 Rm - Laundry RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-27 Rm - Ext - Closet RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-28 Rm - Ext -
Electrical
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-29 Rm - Ext - Closet RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 24 24
ballast
Rf#-30 Rm - Garage RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 2 Lighting Page 13 148 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 2 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-31 Rm - Ext - LED 1L flood, flag light, LED, n/a 1 1 Ground Mount
DND - DND: (do not do, fixtures left as is)
Rf#-32 Rm - Ext - Pole LED 1L SB, LED, n/a 0
Mount
DND - DND: (do not do, fixtures left as is)
CF 2L sm wall pack, CFP-13W 2 pin, CF 9 9
ballast
Rf#-33 Rm - Ext - Wall
Mount
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
MH 1L wm wall pack large, MH 150W, 10 10
HID ballast
Rf#-34 Rm - Ext - Wall
Mount
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
Rf#-35 Rm - Ext - Ceiling CF 2L rec can 8", CFP-26w, CF ballast 4 4 Mount
RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 8" trim ring extender
1x4x 2L sm vapor tight, F32T8 32w, 1 1
electronic ballast
Rf#-36 Rm - Ext - Ceiling
Mount
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2nd Floor
Rf#-37 Rm - Hall CF 2L rec can 8", CFP-26w, CF ballast 22 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 22 L70 rated life, (1) 8" trim ring extender
Rf#-38 Rm - Hall CF 1L rec step light, CFP-13W, CF ballast 9 RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated 9 life, remove ballast from service
Rf#-39 Rm - Pole CF 2L rec can 8", CFP-26w, CF ballast 3 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 3 L70 rated life, (1) 8" trim ring extender
Rf#-40 Rm - RR CF 2L rec can 8", CFP-26w, CF ballast 8 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 8 L70 rated life, (1) 8" trim ring extender
2x4x 3L rec trf, F32T8 32w, electronic 5 5
ballast
Rf#-41 Rm - RR RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-42 Rm - RR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-43 Rm - Sleep 1 RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Inc. 1L wm reading light, Inc. 60w A19, 2 2
n/a
Rf#-44 Rm - Sleep 1 RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K 2x4x 3L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-45 Rm - Sleep 2 RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Inc. 1L wm reading light, Inc. 60w A19, 2 2
n/a
Rf#-46 Rm - Sleep 2 RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K 2x4x 3L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-47 Rm - Sleep 3 RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Inc. 1L wm reading light, Inc. 60w A19, 2 2
n/a
Rf#-48 Rm - Sleep 3 RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K 2x4x 3L rec trf, F32T8 32w, electronic 6 6
ballast
Rf#-49 Rm - Weight RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Qty for Fire Station No. 2 : 284 284
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 2 Lighting Page 14 149 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 3 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main
1st Floor
Rf#-1 Rm - Lobby CF 1L rec can 8", CFP-26w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-2 Rm - Lobby RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-3 Rm - Electrical RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-4 Rm - Medical CF 2L rec can 8", CFP-26w, CF ballast 5 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 5 L70 rated life, (1) 8" trim ring extender
1x4 1L Strip, F32T8 32w, electronic 6 6
ballast
Rf#-5 Rm - Medical RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-6 Rm - Hall CF 1L rec can 8", CFP-26w, CF ballast 5 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 5 L70 rated life, (1) 8" trim ring extender
2x4x 2L rec trf, F32T8 32w, electronic 7 7
ballast
Rf#-7 Rm - Hall RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-8 Rm - Office 2x4x 2L rec Vol trf, LED ?w, n/a 2 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 2 rated life, remove existing ballast from service
Rf#-9 Rm - Sleep 7 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-10 Rm - Sleep 7 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-11 Rm - Sleep 6 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-12 Rm - Sleep 6 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-13 Rm - Sleep 5 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-14 Rm - Sleep 5 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-15 Rm - Sleep 4 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-16 Rm - Sleep 4 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-17 Rm - Sleep 3 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-18 Rm - Sleep 3 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-19 Rm - Sleep 2 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-20 Rm - Sleep 2 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-21 Rm - Sleep 1 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-22 Rm - Sleep 1 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-23 Rm - RR1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-24 Rm - RR1 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-25 Rm - RR2 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-26 Rm - RR2 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-27 Rm - RR3 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-28 Rm - RR3 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-29 Rm - RR4 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-30 Rm - RR4 CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 3 Lighting Page 15 150 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 3 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
2x4x 2L rec trf, F32T8 32w, electronic 6 6
ballast
Rf#-31 Rm - Kitchen RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-32 Rm - Kitchen Inc. 1L track light, MR 16 50W, n/a 7 RL061/s/mr16 - (1) LED 6w MR16 lamp, 4000K 7 1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-33 Rm - Custodian RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 6 6
ballast
Rf#-34 Rm - TV RL025/tkit24 - (1) LED 25w 2x4 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
1x4x 2L rec trf, F32T8 32w, electronic 24 24
ballast
Rf#-35 Rm - Bay RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-36 Rm - Bay CF 1L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-37 Rm - Supply 1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-38 Rm - RR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-39 Rm - Supply 2 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm strip, F32T8 32w, electronic 8 8
ballast
Rf#-40 Rm - Clothing RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-41 Rm - Weights RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm strip, F32T8 32w, electronic 3 3
ballast
Rf#-42 Rm - Work RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x2x 1L sm wp, F17T8 17w, electronic 7 7
ballast
Rf#-43 Rm - Work RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm strip, F32T8 32w, electronic 2 2
ballast
Rf#-44 Rm - Laundry RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm strip, F32T8 32w, electronic 1 1
ballast
Rf#-45 Rm - Water RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm strip, F32T8 32w, electronic 1 1
ballast
Rf#-46 Rm - Data RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-47 Rm - Ext - Ceiling CF 1L rec can 8", CFP-26w, CF ballast 2 2 Mount
RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 8" trim ring extender
HPS 1L flood, trunion, HPS 200W E39, 3 3
HID ballast
Rf#-48 Rm - Ext - Roof
Edge
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
1x4 1L Vapor Tite, F32T8 32w, electronic 10 10
ballast
Rf#-49 Rm - Shelter RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm strip, F32T8 32w, electronic 2 2
ballast
Rf#-50 Rm - Ext Shed RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-51 Rm - Ext - Pole LPS 1L SB pole mnt, LPS 90w, HID ballast 15 15 Mount
NL040/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 40w (Vly) oemB
Rf#-52 Rm - Ext - Pole LED 1L SB pole mount, LED CC, n/a 1 1 Mount
NL040/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 40w (Vly) oemB
Rf#-53 Rm - Parking LPS 1L SB SqP grey, LPS 90w, HID ballast 5 NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 5 rated life, 70w (Vly) oemB
Rf#-54 Rm - Parking LED 1L area light SqP grey, LED CC, n/a 1 NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 1 rated life, 70w (Vly) oemB
Qty for Fire Station No. 3 : 178 178
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 3 Lighting Page 16 151 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 4 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main
1st Floor
2x2x 3L rec trf, F17T8 17w, electronic 13 13
ballast
Rf#-1 Rm - Lobby / Hall RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 1L wm rec step light, CFP-7w PLS, CF 9 9
ballast
Rf#-2 Rm - Lobby / Hall RL061/h - (1) LED 2 pin lamp, direct wire, Gx23 base, 120/277v, 6w, 50,000-Hr L70 rated life
2x2x 2L rec vol trf, F17T8 17w, electronic 4 4
ballast
Rf#-3 Rm - Office RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-4 Rm - Custodian RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-5 Rm - RR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-6 Rm - RR CF 2L rec can 8", CFP-26w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
2x2x 3L rec trf, F17T8 17w, electronic 6 6
ballast
Rf#-7 Rm - Kitchen RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-8 Rm - Kitchen CF 1L rec can 6", CFP-26w, CF ballast 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
2x2x 3L rec trf, F17T8 17w, electronic 4 4
ballast
Rf#-9 Rm - TV RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
Rf#-10 Rm - TV CF 1L rec can 6", CFP-26w, CF ballast 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life L-DS
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-11 Rm - Data RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-12 Rm - RR1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-13 Rm - RR2 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 1 1
ballast
Rf#-14 Rm - Closet RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 2 2
ballast
Rf#-15 Rm - Sleep 5 RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 2 2
ballast
Rf#-16 Rm - Sleep 4 RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 2 2
ballast
Rf#-17 Rm - Sleep 3 RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 2 2
ballast
Rf#-18 Rm - Sleep 2 RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 3L rec trf, F17T8 17w, electronic 2 2
ballast
Rf#-19 Rm - Sleep 1 RLT823dw - (3) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 27 27
ballast
Rf#-20 Rm - Bay RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 3L wm wall wash, F32T8 32w, 1 1
electronic ballast
Rf#-21 Rm - Bay - Map
Lite
RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 4L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-22 Rm - Laundry RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-23 Rm - Laundry RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-24 Rm - Clothing RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 6 6
ballast
Rf#-25 Rm - Weights RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-26 Rm - Custodian RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-27 Rm - Ext -
Electrical
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 1L wm wall pack small, CFP-32w, CF 9 9
ballast
Rf#-28 Rm - Ext - Wall
Mount
RL0111/h - (1) LED 4 pin lamp, direct wire, 120/277v, 11w, 50,000-Hr L70 rated life, horizontal
CF 1L flood, knuckle 1/2", CFP-42w, CF 3 3
ballast
Rf#-29 Rm - Ext - Wall
Mount
NL035/fld - New LED flood, knuckle mount, 50,000-Hr L70 rated life, 35w (Key)
Rf#-30 Rm - Ext - Wall LPS 2L SB SqP BZ, LPS 90w, HID ballast 3 3 Mount
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 4 Lighting Page 17 152 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 4 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-31 Rm - Ext - Pole LPS 2L SB SqP BZ, LPS 90w, HID ballast 6 6 Mount
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-32 Rm - Shed RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Qty for Fire Station No. 4 : 127 127
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 4 Lighting Page 18 153 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 5 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main
1st Floor
Rf#-1 Rm - Lobby CF 1L rec can 8", CFP-32w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-2 Rm - RR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-3 Rm - Hall CF 1L rec can 8", CFP-32w, CF ballast 11 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 11 L70 rated life, (1) 8" trim ring extender
1x4x 1L sm strip (cove), F32T8 32w, 8 8
electronic ballast
Rf#-4 Rm - Hall RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec trf, FB31T8 32w U6, 4 4
electronic ballast
Rf#-5 Rm - Office 1 RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) 2x2x 2L rec trf, FB31T8 32w U6, 4 4
electronic ballast
Rf#-6 Rm - Office 2 RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) Rf#-7 Rm - RR / Locker CF 1L rec can 8", CFP-32w, CF ballast 12 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 12 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 11 11
ballast
Rf#-8 Rm - RR / Locker RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-9 Rm - Closet RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 2L sm strip, F25T8 25w, electronic 1 1
ballast
Rf#-10 Rm - Data RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec trf, FB31T8 32w U6, 4 4
electronic ballast
Rf#-11 Rm - Mail RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) Rf#-12 Rm - TV CF 1L rec can 8", CFP-32w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
2x2x 2L rec trf, FB31T8 32w U6, 6 6
electronic ballast
Rf#-13 Rm - TV RL025/tkit22 - (1) LED 25w 2x2 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
1x3x 2L sm strip, F25T8 25w, electronic 1 1
ballast
Rf#-14 Rm - Closet RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 2L sm strip, F25T8 25w, electronic 1 1
ballast
Rf#-15 Rm - Water RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-16 Rm - Kitchen CF 1L rec can 6", CFP-26w, CF ballast 8 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 8 rated life
2x2x 2L rec trf, FB31T8 32w U6, 1 1
electronic ballast
Rf#-17 Rm - Sleep 1 RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) 1x2x 1L wm light (reading), F17T8 17w, 1 1
electronic ballast
Rf#-18 Rm - Sleep 1 RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec trf, FB31T8 32w U6, 1 1
electronic ballast
Rf#-19 Rm - Sleep 2 RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) 1x2x 1L wm light (reading), F17T8 17w, 1 1
electronic ballast
Rf#-20 Rm - Sleep 2 RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec trf, FB31T8 32w U6, 1 1
electronic ballast
Rf#-21 Rm - Sleep 3 RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) 1x2x 1L wm light (reading), F17T8 17w, 1 1
electronic ballast
Rf#-22 Rm - Sleep 3 RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec trf, FB31T8 32w U6, 1 1
electronic ballast
Rf#-23 Rm - Sleep 4 RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) 1x2x 1L wm light (reading), F17T8 17w, 1 1
electronic ballast
Rf#-24 Rm - Sleep 4 RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x3x 2L sm strip, F25T8 25w, electronic 1 1
ballast
Rf#-25 Rm - Sleep 4 RLT832dw - (2) 3' LED T8 lamp 12w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec trf, FB31T8 32w U6, 1 1
electronic ballast
Rf#-26 Rm - Sleep 5 RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) 1x2x 1L wm light (reading), F17T8 17w, 1 1
electronic ballast
Rf#-27 Rm - Sleep 5 RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x2x 2L rec trf, FB31T8 32w U6, 1 1
electronic ballast
Rf#-28 Rm - Sleep 6 RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) 1x2x 1L wm light (reading), F17T8 17w, 1 1
electronic ballast
Rf#-29 Rm - Sleep 6 RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec vol trf, F32T8 32w, electronic 22 22
ballast
Rf#-30 Rm - Bay RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 5 Lighting Page 19 154 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 5 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
1x4x 2L rec vol trf, F32T8 32W RED, 6 6
electronic ballast
Rf#-31 Rm - Bay RLT842dw(Tgred) - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000- Hr L70 rated life, remove existing ballast from service, (1) red colored tube Rf#-32 Rm - Bay CF 1L rec can 8", CFP-32w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
2x4x 3L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-33 Rm - Clothing RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 5 5
ballast
Rf#-34 Rm - Work RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-35 Rm - Weights RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-36 Rm - Ext - Hose RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-37 Rm - Ext -
Electrical
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-38 Rm - Ext - Ceiling CF 1L rec can 8", CFP-32w, CF ballast 2 2 Mount
RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 8" trim ring extender
Rf#-39 Rm - Ext - Wall LED 1L sm square, LED, n/a 2 2
Mount
DND - DND: (do not do, fixtures left as is)
Rf#-40 Rm - Ext - Wall CF 1L wm wall dome, CFP-32w, CF ballast 5 5 Mount
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
1x4x 1L wm sconce (vertical), F32T8 2 2
32w, electronic ballast
Rf#-41 Rm - Ext - Wall
Mount
RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-42 Rm - Ext - Pole LPS 1L SB Sqp grey, LPS 90w, HID ballast 4 4 Mount
NL040/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 40w (Vly) oemB
Rf#-43 Rm - Ext - LED 1L bollard, LED, n/a 2 2
Ground Mount
DND - DND: (do not do, fixtures left as is)
1x4x 2L sm wp, F32T8 32w, electronic 3 3
ballast
Rf#-44 Rm - Fuel Area RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Qty for Fire Station No. 5 : 155 155
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 5 Lighting Page 20 155 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 6 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main Bldg
1st Floor
Rf#-1 Rm - entry lobby LED 1L rec can, LED Pin lamp 13w, n/a 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
Rf#-2 Rm - lobby RR CF 1L rec can 8", CFP-32w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-3 Rm - lobby RR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-4 Rm - CF 1L rec can 8", CFP-32w, CF ballast 3 3
hallway/desk area
RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 8" trim ring extender
2x4x 2L rec trf, F32T8 32w, electronic 7 7
ballast
Rf#-5 Rm -
hallway/desk area
RL025/tkit24 - (1) LED 25w 2x4 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x4x 3L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-6 Rm - Office #1 RL025/tkit24 - (1) LED 25w 2x4 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-7 Rm - Server Room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-8 Rm - water heater
room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 24 24
ballast
Rf#-9 Rm - Garage Bays RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-10 Rm - laundry
room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-11 Rm - tool room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-12 Rm - ? Room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-13 Rm - ? Room
inside above
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-14 Rm - Locker
Room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-15 Rm - Locker
Room RR
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 6 6
ballast
Rf#-16 Rm - wieght
room
RL025/tkit24 - (1) LED 25w 2x4 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
2x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-17 Rm - dorm
hallway
RL025/tkit24bt - (1) LED 25w 2x4 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
Rf#-18 Rm - dorm CF 1L wm step light, CFP-18w, CF ballast 7 7 hallway
RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated life, remove ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast dimming
Rf#-19 Rm - TV Room RL025/tkit24bt - (1) LED 25w 2x4 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
Rf#-20 Rm - kitchen CF 1L rec can?", CFP-32w, CF ballast 6 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 6 rated life
Rf#-21 Rm - kitchen CF 1L rec can?", CFP-32w, CF ballast 5 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 5 rated life
Rf#-22 Rm - kitchen Inc. 1L rec can?", Inc. 1L MR16 35w, n/a 3 RL061/s/mr16 - (1) LED 6w MR16 lamp, 4000K 3 1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-23 Rm - water
heater room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-24 Rm - Dorm CF 1L rec can?", CFP-32w, CF ballast 1 1 Room #1
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x2x 1L wm light, F17T8 17w, electronic 2 2
ballast
Rf#-25 Rm - Dorm
Room #1
RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-26 Rm - Dorm CF 1L rec can?", CFP-32w, CF ballast 1 1 Room #2
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x2x 1L wm light, F17T8 17w, electronic 2 2
ballast
Rf#-27 Rm - Dorm
Room #2
RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-28 Rm - Dorm CF 1L rec can?", CFP-32w, CF ballast 1 1 Room #3
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x2x 1L wm light, F17T8 17w, electronic 2 2
ballast
Rf#-29 Rm - Dorm
Room #3
RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-30 Rm - Dorm CF 1L rec can?", CFP-32w, CF ballast 1 1 Room #4
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 6 Lighting Page 21 156 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 6 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
1x2x 1L wm light, F17T8 17w, electronic 2 2
ballast
Rf#-31 Rm - Dorm
Room #4
RLT821dw - (1) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-32 Rm - RR #1 CF 1L rec can?", CFP-32w, CF ballast 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-33 Rm - RR #1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-34 Rm - RR #2 CF 1L rec can?", CFP-32w, CF ballast 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-35 Rm - RR #2 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-36 Rm - RR #3 CF 1L rec can?", CFP-32w, CF ballast 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-37 Rm - RR #3 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
(est) 1x4x 2L sm strip, F32T8 32w, 1 1
electronic ballast
Rf#-38 Rm - Electrical
Rm (ext entry)
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
MH 1L wm wall dome, MH 50W E26, HID 8 8
ballast
Rf#-39 Rm - Ext - Wall
Mount
RL0241/s/md - (1) LED 24w corn cob style screw in lamp, 120/277, 50,000-Hr rated life, 5700K, medium base
Rf#-40 Rm - Ext - Ceiling CF 1L rec can 8", CFP-32w, CF ballast 4 4 Mount
RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 8" trim ring extender
1x4 1L Vapor Tite, F32T8 32w, electronic 6 6
ballast
Rf#-41 Rm - Ext - Shelter RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-42 Rm - Shed RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4 1L Vapor Tite, F32T8 32w, electronic 4 4
ballast
Rf#-43 Rm - Fuel Area RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
LPS 1L SB SqP orange, LPS 90w, HID 8 8
ballast
Rf#-44 Rm - Ext - Pole
Mount
NL040/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 40w (Vly) oemB
HPS 1L flood, adj tenon, HPS 200W, HID 4 4
ballast
Rf#-45 Rm - Ext - Pole
Mount
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Qty for Fire Station No. 6 : 149 149
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 6 Lighting Page 22 157 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 7 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main
1st Floor
Rf#-1 Rm - Lobby CF 2L rec can 8", CFP-26w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
Rf#-2 Rm - RR CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-3 Rm - RR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-4 Rm - Office CF 2L rec can 8", CFP-26w, CF ballast 5 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 5 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 9 9
ballast
Rf#-5 Rm - Office RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-6 Rm - Hall CF 2L rec can 8", CFP-26w, CF ballast 6 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 6 L70 rated life, (1) 8" trim ring extender
2x4x 2L rec trf, F32T8 32w, electronic 7 7
ballast
Rf#-7 Rm - Hall RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-8 Rm - Office RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-9 Rm - Sleep 1 CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-10 Rm - Sleep 1 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-11 Rm - Sleep 2 CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-12 Rm - Sleep 2 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-13 Rm - Sleep 3 CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-14 Rm - Sleep 3 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-15 Rm - Sleep 4 CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-16 Rm - Sleep 4 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-17 Rm - Sleep 5 CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-18 Rm - Sleep 5 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-19 Rm - Sleep 6 CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-20 Rm - Sleep 6 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-21 Rm - Sleep 7 CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x2x 2L wm light (reading), F17T8 17w, 2 2
electronic ballast
Rf#-22 Rm - Sleep 7 RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-23 Rm - RR1 CF 2L rec can 8", CFP-26w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-24 Rm - RR1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-25 Rm - RR2 CF 2L rec can 8", CFP-26w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-26 Rm - RR2 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-27 Rm - RR3 CF 2L rec can 8", CFP-26w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-28 Rm - RR3 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-29 Rm - RR4 CF 2L rec can 8", CFP-26w, CF ballast 2 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-30 Rm - RR4 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 7 Lighting Page 23 158 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Fire Station No. 7 -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-31 Rm - Kitchen LED 1L track , LED ?w MR16, n/a 7 DND - DND: (do not do, fixtures left as is) 7 2x4x 2L rec trf, F32T8 32w, electronic 6 6
ballast
Rf#-32 Rm - Kitchen RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 6 6
ballast
Rf#-33 Rm - Unknown RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-34 Rm - Unknown RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 6 6
ballast
Rf#-35 Rm - TV RL025/tkit24 - (1) LED 25w 2x4 rec trf kit w/volumetric lens 70,000-Hr L70 rated life (ALE) L-DS
1x4x 2L rec trf, F32T8 32w, electronic 24 24
ballast
Rf#-36 Rm - Bay RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-37 Rm - Bay CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-38 Rm - Supply 1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-39 Rm - RR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-40 Rm - Supply 2 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 8 8
ballast
Rf#-41 Rm - Clothing RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-42 Rm - Weights RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-43 Rm - Work RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-44 Rm - Laundry RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-45 Rm - Laundry CF 2L rec can 8", CFP-26w, CF ballast 6 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 6 L70 rated life, (1) 8" trim ring extender
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-46 Rm - Water RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-47 Rm - Data RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-48 Rm - Electrical RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-49 Rm - Ext - Ceiling CF 2L rec can 8", CFP-26w, CF ballast 2 2 Mount
RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 8" trim ring extender
Rf#-50 Rm - Ext - Wall LED 1L wm wall dome, LED CC, n/a 0 Mount
DND - DND: (do not do, fixtures left as is)
1x4 1L Varpor Tite, F32T8 32w, 11 11
electronic ballast
Rf#-51 Rm - Shelter -
Fuel
RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-52 Rm - Shed RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
HPS 1L rec square, HPS 50W E26, HID 10 10
ballast
Rf#-53 Rm - Ext - Wall
Mount
RL0161/s/md - (1) LED 16w A21 style screw in lamp, 120/277, 50,000-Hr rated life, 4000K, medium base
HPS 1L flood, trunion, HPS 200W, HID 4 4
ballast
Rf#-54 Rm - Ext - Pole
Mount
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Rf#-55 Rm - Ext - Pole LPS 1L SB Sqp grey, LPS 90w, HID ballast 12 12 Mount
NL040/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 40w (Vly) oemB
Qty for Fire Station No. 7 : 191 191
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Fire Station No. 7 Lighting Page 24 159 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Grape Day Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Grape Day Park & Bldg Walks
1st Floor
MH 1L post top 2 3/8 Grey, MH 100W 36 36
E26, HID ballast
Rf#-1 Rm - Ext - Pole
Mount
RL0341/s/md - (1) LED 34w A21 style screw in lamp, 120/277, 50,000-Hr rated life, 5000K, medium base
DND (do not do, left as is), no lighitng, 0
n/a
Rf#-2 Rm - All other
Exterior Space
DND - DND: (do not do, fixtures left as is)
Qty for Grape Day Park : 36 36
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Grape Day Park Lighting Page 25 160 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Hale Avenue Resource & Recovery Facility ("HARRF") -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Admin Wings
1st Floor
Rf#-1 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-2 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Areation Basins
1st Floor
Rf#-17 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Butler Building
1st Floor
1x4x 2L sm ind hood, F32T8 32w, 28 28
electronic ballast
Rf#-34 Rm - Butler
Building open area
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-35 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
Rf#-36 Rm - Ext-Bldg HPS 1L sm square, HPS 70w, HID ballast 2 2 Mnt (eaves)
NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) HPS 1L wm wall pack FT lrg, HPS 100w, 1 1
HID ballast
Rf#-37 Rm - Ext-Bldg
Mnt (walls)
NL030/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 30w () Rf#-38 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Exterior Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Chem Enh Prim Treat
1st Floor
1x4x 2L sm vapor tight, F32T8 32w, 1 1
electronic ballast
Rf#-10 Rm - CEPT RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-11 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
Rf#-12 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Chem Tank Farm
1st Floor
Rf#-24 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-25 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Chlorine Contact Basin
1st Floor
Rf#-67 Rm - No Interior DND (do not do, left as is), n/a, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-68 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Exterior Space
DND - DND: (do not do, fixtures left as is)
Building/Area: DAF
1st Floor
Rf#-31 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
1x4x 2L sm vapor tight, F32T8 32w, 4 4
electronic ballast
Rf#-32 Rm - ? Room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
HPS 1L wm wall pack FT lrg, HPS 100w, 7 7
HID ballast
Rf#-33 Rm - Ext-Bldg
Mnt (walls)
NL030/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 30w () Building/Area: DAF ? (by Seconday Digester)
1st Floor
Rf#-39 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-40 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Hale Avenue Resource & Recovery Facility ("HARRF") Lighting Page 26 161 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Hale Avenue Resource & Recovery Facility ("HARRF") -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Generator Bldg
1st Floor
1x4x 2L sm ind hood, F32T8 32w, 16 16
electronic ballast
Rf#-41 Rm - Backup Gen
Room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm vapor tight, F32T8 32w, 2 2
electronic ballast
Rf#-42 Rm - Small Bldg
nxt to above
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-43 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
HPS 1L wm wall pack FT lrg, HPS 100w, 2 2
HID ballast
Rf#-44 Rm - Ext-Bldg
Mnt (walls)
NL030/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 30w () Rf#-45 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Exterior Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Headworks
1st Floor
Rf#-3 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
HPS 1L wm wall pack FT lrg, HPS 100w, 4 4
HID ballast
Rf#-4 Rm - Pump Pit #1 NL030/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 30w () HPS 1L wm wall pack FT lrg, HPS 100w, 4 4
HID ballast
Rf#-5 Rm - Pump Pit #2 NL030/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 30w () Rf#-6 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 exterior space
DND - DND: (do not do, fixtures left as is)
Building/Area: Maintenance Bldg
1st Floor
1x8x 2L sm vaport tight, F96T8 59w, 11 11
electronic ballast
Rf#-46 Rm -
Maintenace Shop (open
NL055/8s - New 8' LED surface mount narrow wrap, 50,000-Hr L70 rated life, 55w, 4000K (ALE)
1x4x 2L sm box, F32T8 32w, electronic 12 12
ballast
Rf#-47 Rm -
Maintenace Shop (open
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-48 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
Rf#-49 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Order Control
1st Floor
Rf#-7 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
HPS 1L wm wall pack FT lrg, HPS 100w, 4 4
HID ballast
Rf#-8 Rm - Ext-Bldg Mnt
(walls)
NL030/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 30w () Rf#-9 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 exterior space
DND - DND: (do not do, fixtures left as is)
Building/Area: Primary Clarifiers
1st Floor
1x4x 2L sm vapor tight, F32T8 32w, 10 10
electronic ballast
Rf#-13 Rm - Primary
Sludge Pump Rm #1
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm vapor tight, F32T8 32w, 12 12
electronic ballast
Rf#-14 Rm - Pipe Galley
Primary Clarifiers
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-15 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
Rf#-16 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Primary Digestors 1-3
1st Floor
Rf#-50 Rm - No Interior DND (do not do, left as is), n/a, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-51 Rm - Ext-Pole HPS 1L shoe box, HPS 150w, HID ballast 5 5 Mnt
NL040/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 40w (Vly) oemB
Rf#-52 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Exterior Space
DND - DND: (do not do, fixtures left as is)
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Hale Avenue Resource & Recovery Facility ("HARRF") Lighting Page 27 162 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Hale Avenue Resource & Recovery Facility ("HARRF") -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: RAS/WAS Pump Station
1st Floor
Rf#-71 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
HPS 1L wm wall pack FT lrg, HPS 100w, 2 2
HID ballast
Rf#-72 Rm - Ext-Bldg
Mnt (walls) pump pit
NL030/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 30w () Rf#-73 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Exterior Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Rentention Resivour
1st Floor
Rf#-62 Rm - No Interior DND (do not do, left as is), n/a, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-63 Rm - Ext-Pole HPS 1L shoe box, HPS 250w, HID ballast 2 2 Mnt
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Rf#-64 Rm - Ext-Pole LED 1L shoe box, LED ?w, n/a 2 2
Mnt
DND - DND: (do not do, fixtures left as is)
Building/Area: Screen & Influent Pump
1st Floor
1x4x 2L sm vapor tight, F32T8 32w, 4 4
electronic ballast
Rf#-26 Rm - ? Room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
HPS 1L wm wall pack FT lrg, HPS 100w, 4 4
HID ballast
Rf#-27 Rm - Ext-Bldg
Mnt (walls)
NL030/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 30w () Rf#-28 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Exterior Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Secodary Eff Pump St (SEPS)
1st Floor
Rf#-65 Rm - No Interior DND (do not do, left as is), n/a, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-66 Rm - Ext-Pole HPS 1L shoe box, HPS 250w, HID ballast 9 9 Mnt
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Building/Area: Solids Building
1st Floor
Rf#-59 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
Rf#-60 Rm - Ext-Pole HPS 1L shoe box, HPS 150w, HID ballast 3 3 Mnt
NL040/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 40w (Vly) oemB
Rf#-61 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Exterior Space
DND - DND: (do not do, fixtures left as is)
2nd Floor
HPS 1L large pm square, HPS 400w, HID 17 17
ballast
Rf#-53 Rm - Centrifuge
area
NL150/exp - New LED surface mnt dome., 50,000-Hr L70 rated life, 150w (Rb)
1x4x 2L sm vapor tight, F32T8 32w, 6 6
electronic ballast
Rf#-54 Rm - Centrifuge
area
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm ind hood, F32T8 32w, 1 1
electronic ballast
Rf#-55 Rm -
Compressor room in
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 4L rec trf, F32T8 32w, electronic 7 7
ballast
Rf#-56 Rm - Centrifuge
Office area
RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-57 Rm - Centrifuge Inc. 1L sm fxt, Inc. 60w, n/a 1 1 Office area RR
RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K
2x4x 4L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-58 Rm - Centrifuge
MCC
RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Building/Area: Tertiary Filters
1st Floor
1x4x 2L sm ind hood, F32T8 32w, 6 6
electronic ballast
Rf#-18 Rm - Tertiary
Control area
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm ind hood, F32T8 32w, 7 7
electronic ballast
Rf#-19 Rm - Tertiary
Galley (samples chase)
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Hale Avenue Resource & Recovery Facility ("HARRF") Lighting Page 28 163 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Hale Avenue Resource & Recovery Facility ("HARRF") -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-20 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 interior Space
DND - DND: (do not do, fixtures left as is)
Rf#-21 Rm - Ext-Pole HPS 1L shoe box, HPS 150w, HID ballast 15 15 Mnt (Tertiary)
NL040/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 40w (Vly) oemB
HPS 1L wm wall pack FT lrg, HPS 100w, 2 2
HID ballast
Rf#-22 Rm - Ext-Bldg
Mnt (walls)
NL030/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 30w () Rf#-23 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Exterior Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Utility Water Pumps
1st Floor
Rf#-29 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-30 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: WAS
1st Floor
Rf#-69 Rm - No Interior DND (do not do, left as is), n/a, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-70 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Exterior Space
DND - DND: (do not do, fixtures left as is)
Qty for Hale Avenue Resource & Recovery Facility ("HARRF") : 215 215 W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Hale Avenue Resource & Recovery Facility ("HARRF") Lighting Page 29 164 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Jesmond Dene Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: RR Building
1st Floor
Rf#-2 Rm - Ext-Pole Mnt DND (do not do, left as is), LED ?w, n/a 0 (parking and walkway)
DND - DND: (do not do, fixtures left as is)
Rf#-3 Rm - Ext-Bldg Mnt LED 1L square, LED ?w, n/a 1 1
(walls) RR entry
DND - DND: (do not do, fixtures left as is)
1x4x 2L sm strip TG wire guard, F32T8 2 2
32w, electronic ballast
Rf#-4 Rm - B RR NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) 1x4x 2L sm strip TG wire guard, F32T8 2 2
32w, electronic ballast
Rf#-5 Rm - G RR NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) 1x4x 2L sm strip TG wire guard, F32T8 2 2
32w, electronic ballast
Rf#-6 Rm - storage #1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm strip TG wire guard, F32T8 2 2
32w, electronic ballast
Rf#-7 Rm - equipment
room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-8 Rm - chalking LED 1L fxt, LED ?w SI P38, n/a 1 1
equipment
NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) HPS 1L wm wall pack LG, HPS 100w, HID 6 6
ballast
Rf#-9 Rm - Ext-Bldg Mnt
(walls)
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
Building/Area: Sports Fields
1st Floor
DND (do not do, left as is), MUSCO LED, 0
n/a
Rf#-1 Rm - All Sports
Fields
DND - DND: (do not do, fixtures left as is)
Qty for Jesmond Dene Park : 16 16
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Jesmond Dene Park Lighting Page 30 165 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Kit Carson Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Adult Softball
1st Floor
Rf#-65 Rm - B RR LED 1L screw in, LED ?w, n/a 3 DND - DND: (do not do, fixtures left as is) 3 Rf#-66 Rm - G RR LED 1L screw in, LED ?w, n/a 3 DND - DND: (do not do, fixtures left as is) 3 1x8x 1L sm strip, F96T12 60w, magnetic 2 2
ballast
Rf#-67 Rm - chase NL055/8s - New 8' LED surface mount narrow wrap, 50,000-Hr L70 rated life, 55w, 4000K (ALE)
(est) 1x4x 2L sm wp, F32T8 32w, 4 4
electronic ballast
Rf#-68 Rm - Snack bar RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
(est) 1x4x 2L sm wp, F32T8 32w, 4 4
electronic ballast
Rf#-69 Rm - ump rooom RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
LPS 1L wm wall pack FT, LPS 55w, HID 4 4
ballast
Rf#-70 Rm - Ext-Bldg
Mnt (walls)
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
Building/Area: Amphitheater
1st Floor
1x8x 2L sm strip (narrow), F96T12 60w, 3 3
magnetic ballast
Rf#-11 Rm - Back stage
walkway
NL055/8s - New 8' LED surface mount narrow wrap, 50,000-Hr L70 rated life, 55w, 4000K (ALE)
1x8x 4L sm strip (narrow), TLED, 1 1
electronic ballast
Rf#-12 Rm - Back stage
walkway
DND - DND: (do not do, fixtures left as is)
Rf#-13 Rm - Old B RR DND (do not do, left as is), LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 Rf#-14 Rm - Old G RR DND (do not do, left as is), LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 1x4x 2L sm box, F32T8 32w, electronic 2 2
ballast
Rf#-15 Rm - ExtWalkwayRLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
MH 1L flood, tenon, MH 400w, HID 12 12
ballast
Rf#-16 Rm -
Amphitheater (seating
NL100/p/sbt - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 100w (Vly) oemB
Rf#-17 Rm - Ext-Bldg CF 1L wm vandal, CFP-26w, CF ballast 7 7 Mnt (walls) Amphitheater
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
(est) 1x4x 2L sm wp, F32T8 32w, 4 4
electronic ballast
Rf#-18 Rm - Snack area
RR #1
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-19 Rm - B & G RR DND (do not do, left as is), LED ?w, n/a 0 (RR#1)
DND - DND: (do not do, fixtures left as is)
Rf#-20 Rm - Plumbing Inc. 1L bare bulb, Inc. 60w, n/a 1 1 Chase (RR#1)
RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K
Rf#-21 Rm - Ext-Bldg CF 1L wm vandal, CFP-26w, CF ballast 3 3 Mnt (walls) RR#1
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
(est) 1x4x 2L sm wp, F32T8 32w, 4 4
electronic ballast
Rf#-22 Rm - Snack area
RR #2
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm vapor tight, F32T8 32w, 4 4
electronic ballast
Rf#-23 Rm - B & G RR
(RR#2)
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm ind hood, F40T12 34w, 1 1
magnetic ballast
Rf#-24 Rm - Plumbing
Chase (RR#2)
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-25 Rm - Ext-Bldg CF 1L wm vandal, CFP-26w, CF ballast 3 3 Mnt (walls) RR2
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
Building/Area: Maintenance Bldg
1st Floor
1x8x 2L sm strip (wide), F96T12 60w, 3 3
magnetic ballast
Rf#-1 Rm - Garage Bay
#1
NL055/8s - New 8' LED surface mount narrow wrap, 50,000-Hr L70 rated life, 55w, 4000K (ALE)
1x8x 2L sm strip (wide), F96T12 60w, 4 4
magnetic ballast
Rf#-2 Rm - Garage Bay
#2
NL055/8s - New 8' LED surface mount narrow wrap, 50,000-Hr L70 rated life, 55w, 4000K (ALE)
1x4x 2L sm ind hood, F32T8 32w, 1 1
electronic ballast
Rf#-3 Rm - Storage room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
LPS 1L wm wall pack FT, LPS 55w, HID 1 1
ballast
Rf#-4 Rm - Ext-Bldg Mnt
(walls)
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
Building/Area: Parking Lots and Drives
1st Floor
Rf#-84 Rm - Ext-Pole LED 1L fixtures, LED ?w, n/a 0
Mnt (parking)
DND - DND: (do not do, fixtures left as is)
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Kit Carson Park Lighting Page 31 166 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Kit Carson Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-85 Rm - Ext-Pole LED 1L post top acorn heads, LED ?w, n/a 27 27 Mnt (drives and parking)
DND - DND: (do not do, fixtures left as is)
LPS 1L post top acron head, LPS 55w, 12 12
HID ballast
Rf#-86 Rm - Ext-Pole
Mnt (drives and parking)
RL0451/s/mg - (1) LED 45w corn cob style screw in lamp, 120/277, 50,000-Hr rated life, 5000K, mogul base
Building/Area: Ray Love Tennis
1st Floor
LPS 1L wm wall pack FT, LPS 90w, HID 2 2
ballast
Rf#-43 Rm - Ext-Bldg
Mnt (walls) main bldg
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
Rf#-44 Rm - Ext-Bldg CF 2L sm square, CFP-26w, CF ballast 8 8 Mnt (eaves)
NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) Rf#-45 Rm - Electrical 1x4x 2L sm strip, TLED, electronic ballast 1 1 Rm (ext entry)
DND - DND: (do not do, fixtures left as is)
Rf#-46 Rm - B RR DND (do not do, left as is), LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 Rf#-47 Rm - G RR DND (do not do, left as is), LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 Rf#-48 Rm - Chase DND (do not do, left as is), LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 CF 1L wm LP vandal HZ, CFP-18w, CF 1 1
ballast
Rf#-49 Rm - Ext-Bldg
Mnt (walls) RR entry
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
Building/Area: RR Bldg El Arroyo
1st Floor
2x4x 4L troffer (behind cage), TLED, 4 4
electronic ballast
Rf#-8 Rm - B & G RR DND - DND: (do not do, fixtures left as is) 1x4x 2L sm strip, F32T8 32w, electronic 1 1
ballast
Rf#-9 Rm - custodial
room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-10 Rm - Ext-Bldg CF 1L wm vandal, CFP-26w, CF ballast 3 3 Mnt (walls)
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
Building/Area: RR Bldg North
1st Floor
2x4x 4L troffer (behind cage), TLED, 4 4
electronic ballast
Rf#-5 Rm - B & G RR DND - DND: (do not do, fixtures left as is) 1x4x 2L sm strip, F32T8 32w, electronic 1 1
ballast
Rf#-6 Rm - custodial
room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-7 Rm - Ext-Bldg Mnt CF 1L wm vandal, CFP-26w, CF ballast 3 3 (walls)
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
Building/Area: Sports Ltg Adult Softball
1st Floor
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-71 Rm - Sports
Lighting Pole #P6
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Building/Area: Sports Ltg Soccer
1st Floor
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-72 Rm - Sports
Lighting Pole #S1
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-73 Rm - Sports
Lighting Pole #S2
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-74 Rm - Sports
Lighting Pole #S3
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Building/Area: Sports Ltg Youth Baseball
1st Floor
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-75 Rm - Sports
Lighting Pole #BB1
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-76 Rm - Sports
Lighting Pole #BB4
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-77 Rm - Sports
Lighting Pole #BB5
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-78 Rm - Sports
Lighting Pole #SB2
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Kit Carson Park Lighting Page 32 167 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Kit Carson Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-79 Rm - Sports
Lighting Pole #SB3
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-80 Rm - Sports
Lighting Pole #SB6
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-81 Rm - Sports
Lighting Pole #SB7
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-82 Rm - Sports
Lighting Pole #SB9
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L shoe box security light, LPS 180w, 1 1
HID ballast
Rf#-83 Rm - Sports
Lighting Pole #SB11
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Building/Area: Sports Park
1st Floor
2x4x 3L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-26 Rm - Main Office RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-27 Rm - Office #1 in
above
RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-28 Rm - Reception 2x2x 2L rec trf, Biax 40w, CF ballast 2 2 for Main office
RL017/bx2 - (2) LED BIAX PL-L lamp, direct wire (remove old ballast), 120/277v, 15w, 50,000-Hr L70 rated life
Rf#-29 Rm - Reception 2x2x 2L rec trf, LED 18w, n/a 1 1 for Main office
DND - DND: (do not do, fixtures left as is)
2x2x 2L rec trf, FB31T8 32w U6, 1 1
electronic ballast
Rf#-30 Rm - Reception
for Main office
RLT822udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) 1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-31 Rm - Office #2 in
above
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-32 Rm - Electrical
Rm (ext entry)
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 3 3
ballast
Rf#-33 Rm - Sports
Equip Retail Shop
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-34 Rm - Ext-Bldg CF 2L flood, knuckle, CFP-18w, CF ballast 2 2 Mnt (walls) recep
NL035/fld - New LED flood, knuckle mount, 50,000-Hr L70 rated life, 35w (Key)
2x4x 3L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-35 Rm - G RR RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-36 Rm - B RR RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 2L sm square (broken lens), CFP-26w, 3 3
CF ballast
Rf#-37 Rm - janitor
closet
NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) Rf#-38 Rm - Ext-Bldg CF 2L sm square, CFP-26w, CF ballast 4 4 Mnt (eaves( above BG
NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) (est) 1x4x 2L sm wp, F32T8 32w, 4 4
electronic ballast
Rf#-39 Rm - Snack shop RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-40 Rm - Hockey CF 6L pm high bays, CFP-42w, CF ballast 42 42 Rink #1
NL120/hb/sbt - New LED area interior high bay, 75,000-Hr L70 rated life, lens, 120w, dimming capable (ALE) oemB
Rf#-41 Rm - Hockey CF 6L pm high bays, CFP-42w, CF ballast 42 42 Rink #2
NL120/hb/sbt - New LED area interior high bay, 75,000-Hr L70 rated life, lens, 120w, dimming capable (ALE) oemB
Rf#-42 Rm - Ext-Bldg LPS 2L sm shoe box, LPS 90w, HID ballast 4 4 Mnt (beam) Hockey Rink
NL070/sq/bt - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Building/Area: Tree Lake
1st Floor
Rf#-61 Rm - B RR 2x4x 3L rec trf, TLED, electronic ballast 3 DND - DND: (do not do, fixtures left as is) 3 Rf#-62 Rm - G RR 2x4x 3L rec trf, TLED, electronic ballast 3 DND - DND: (do not do, fixtures left as is) 3 (est) 1x4x 2L sm wp, F32T8 32w, 1 1
electronic ballast
Rf#-63 Rm - custodial
room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 1L wm LP vandal HZ, CFP-26w, CF 3 3
ballast
Rf#-64 Rm - Ext-Bldg
Mnt (walls)
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
Building/Area: youth Baseball Field
1st Floor
Rf#-55 Rm - B RR (est) CFL 1L SI R40, CFS-23w, CF ballast 1 NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) 1 W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Kit Carson Park Lighting Page 33 168 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Kit Carson Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-56 Rm - G RR (est) CFL 1L SI R40, CFS-23w, CF ballast 1 NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) 1 CF 1L wm LP vandal HZ, CFP-18w, CF 1 1
ballast
Rf#-57 Rm - Ext-Bldg
Mnt (walls) RR entry
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
(est) 1x4x 2L sm wp, F32T8 32w, 1 1
electronic ballast
Rf#-58 Rm - custodial
room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
(est) 1x4x 2L sm wp, F32T8 32w, 4 4
electronic ballast
Rf#-59 Rm - snack room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 1L wm LP vandal HZ, CFP-26w, CF 5 5
ballast
Rf#-60 Rm - Ext-Bldg
Mnt (walls)
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
Building/Area: Youth Softball Field
1st Floor
2x4x 3L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-50 Rm - B RR RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-51 Rm - G RR RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
(est) 1x4x 2L sm wp, F32T8 32w, 1 1
electronic ballast
Rf#-52 Rm - custodial
room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
(est) 1x4x 2L sm wp, F32T8 32w, 4 4
electronic ballast
Rf#-53 Rm - snack bar RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF 1L wm LP vandal HZ, CFP-26w, CF 4 4
ballast
Rf#-54 Rm - Ext-BLdg
Mnt (walls)
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
Qty for Kit Carson Park : 314 314
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Kit Carson Park Lighting Page 34 169 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Lake Wohlford Boat House -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Barn
1st Floor
Rf#-3 Rm - Interior 2x4x 2L strip, LED, n/a 8 DND - DND: (do not do, fixtures left as is) 8 2x4x 2L sm strip, F32T8 32w, electronic 4 4
ballast
Rf#-4 Rm - Interior RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-5 Rm - Interior 2x4x 4L sm strip, LED, n/a 3 RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 3 rated life, remove existing ballast from service
2x4x 4L sm strip, F32T8 32w, electronic 5 5
ballast
Rf#-6 Rm - Interior RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 2L sm strip, F32T8 32w, electronic 4 4
ballast
Rf#-7 Rm - Office RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-8 Rm - Ext - Wall LED 1L wm wall pack, LED, n/a 2 2 Mount
DND - DND: (do not do, fixtures left as is)
MH 1L flood, trunion, MH 250W, HID 2 2
ballast
Rf#-9 Rm - Ext - Roof
Edge
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Building/Area: Boat House
1st Floor
1x4x 2L sm vapor tight, F32T8 32w, 1 1
electronic ballast
Rf#-11 Rm - Interior RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-12 Rm - Ext - Pole LED 1L area lights, LED, n/a 2 2 Mount
DND - DND: (do not do, fixtures left as is)
Building/Area: Office Trailer
1st Floor
Rf#-2 Rm - Office Trailer DND (do not do, left as is), LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 Building/Area: Parking
1st Floor
Rf#-10 Rm - Ext - Pole LED 1L SB SqP BZ, LED CC, n/a 5 5 Mount
DND - DND: (do not do, fixtures left as is)
Building/Area: RR Bldg
1st Floor
LPS 1L wm wall pack FT, LPS 55w, HID 4 4
ballast
Rf#-1 Rm - RR Bldg NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
Qty for Lake Wohlford Boat House : 40 40
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Lake Wohlford Boat House Lighting Page 35 170 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Library -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main Building
1st Floor
Rf#-31 Rm - Ext-Bldg DND (do not do, left as is), LED ?w, n/a 0 Mnt (eaves)
DND - DND: (do not do, fixtures left as is)
Rf#-32 Rm - Ext-Bldg DND (do not do, left as is), LED ?w, n/a 0 Mnt (walls)
DND - DND: (do not do, fixtures left as is)
Rf#-33 Rm - Ext-Pole DND (do not do, left as is), LED ?w, n/a 0 Mnt
DND - DND: (do not do, fixtures left as is)
2nd Floor
Rf#-54 Rm - large MH 1L pm can, MH 175w, HID ballast 12 12 meeting room
NL075/hb/bt - New LED area interior high bay, 75,000-Hr L70 rated life, lens, 75w, dimming capable (ALE) L-DS
Rf#-59 Rm - Ext-Bldg DND (do not do, left as is), LED ?w, n/a 0 Mnt (walls)
DND - DND: (do not do, fixtures left as is)
Qty for Library : 12 12
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Library Lighting Page 36 171 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Mathes Center -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main
1st Floor
2x4x 2L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-1 Rm - Lobby / Hall RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 12 12
ballast
Rf#-2 Rm - Meeting RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 4 4
ballast
Rf#-3 Rm - Rec Office RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 4L sm box, F32T8 32w, electronic 11 11
ballast
Rf#-4 Rm - Dance RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 2 2
ballast
Rf#-5 Rm - WRR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 2 2
ballast
Rf#-6 Rm - MRR RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 31 31
ballast
Rf#-7 Rm - Pioneer RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 6 6
ballast
Rf#-8 Rm - Office RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 3L rec trf, F32T8 32w, electronic 2 2
ballast
Rf#-9 Rm - Office RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-10 Rm - Data RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-11 Rm - Storage RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-12 Rm - Ext DND (do not do, left as is), LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 Qty for Mathes Center : 76 76
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Mathes Center Lighting Page 37 172 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Mayflower Dog Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: All
1st Floor
Rf#-1 Rm - Any Interior DND (do not do, left as is), n/a, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
LPS 1L pole moun SB, LPS 135w, HID 1 1
ballast
Rf#-2 Rm - Dog Park
Field 1 Pole #1
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Qty for Mayflower Dog Park : 1 1
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Mayflower Dog Park Lighting Page 38 173 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Mountain View Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Ball Fields
1st Floor
LPS 1L SB sports pole secruity 2-3/8, LPS 1 1
180w, HID ballast 480w
Rf#-1 Rm - Pole 1 NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L SB sports pole secruity 2-3/8, LPS 1 1
180w, HID ballast 480w
Rf#-2 Rm - Pole 3 NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L SB sports pole secruity 2-3/8, LPS 1 1
180w, HID ballast 480w
Rf#-3 Rm - Pole 4 NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L SB sports pole secruity 2-3/8, LPS 1 1
180w, HID ballast 480w
Rf#-4 Rm - Pole 5 NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
LPS 1L SB sports pole secruity 2-3/8, LPS 1 1
180w, HID ballast 480w
Rf#-5 Rm - Pole 7 NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Building/Area: New Building
1st Floor
Rf#-14 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Park Area
1st Floor
Rf#-10 Rm - batting cage LED 1L flood, LED ?w, n/a 8 DND - DND: (do not do, fixtures left as is) 8 MH 1L flood, knuckle, MH 150W, HID 1 1
ballast
Rf#-11 Rm - Flag NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Rf#-12 Rm - Tennis LPS 1L SB SqP BZ, LPS 180W, HID ballast 2 2 Parking
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Rf#-13 Rm - Main LPS 1L SB SqP BZ, LPS 180W, HID ballast 4 4 Parking
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Building/Area: RR Bldg
1st Floor
LPS 1L wm wall pack FT, LPS 55w, HID 2 2
ballast
Rf#-6 Rm - MRR NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
LPS 1L wm wall pack FT, LPS 55w, HID 2 2
ballast
Rf#-7 Rm - WRR NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
1x8x 1L sm strip, F96T8 59w, electronic 1 1
ballast
Rf#-8 Rm - Plumbing
Chase
NL055/8s - New 8' LED surface mount narrow wrap, 50,000-Hr L70 rated life, 55w, 4000K (ALE)
Rf#-9 Rm - NE Parking LPS 1L SB SqP BZ, LPS 180W, HID ballast 2 NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 2 rated life, 70w (Vly) oemB
Qty for Mountain View Park : 27 27
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Mountain View Park Lighting Page 39 174 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Oak Hill Activity Center -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main
1st Floor
1x4x 3L pm fxt, F32T8 32w, electronic 21 21
ballast
Rf#-1 Rm - Main RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-2 Rm - Main CF 2L rec can 10", CFP-26w, CF ballast 6 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 6 L70 rated life, (1) 10" trim ring extender
Rf#-3 Rm - MRR CF 2L rec can 10", CFP-26w, CF ballast 5 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 5 L70 rated life, (1) 10" trim ring extender
1x2x 2L sm wp, F17T8 17w, electronic 2 2
ballast
Rf#-4 Rm - MRR RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-5 Rm - WRR CF 2L rec can 10", CFP-26w, CF ballast 5 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 5 L70 rated life, (1) 10" trim ring extender
1x2x 2L sm wp, F17T8 17w, electronic 2 2
ballast
Rf#-6 Rm - WRR RLT822dw - (2) 2' LED T8 lamp 7w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-7 Rm - Utility RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 3L pm fxt, F32T8 32w, electronic 1 1
ballast
Rf#-8 Rm - Office RLT843dw - (3) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-9 Rm - Storage RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-10 Rm - Ext - Wall LED 1L wm wall pack, LED, n/a 2 2 Mount
DND - DND: (do not do, fixtures left as is)
Rf#-11 Rm - Ext - Wall CF 2L wm wall dome, CFP-32w, CF ballast 6 6 Mount
RL012/fkit - (1) LED 3"x6" module 12w, 120/277, 50,000-Hr L70 rated life, remove ballast from service
Qty for Oak Hill Activity Center : 52 52
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Oak Hill Activity Center Lighting Page 40 175 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Park Avenue Community Center ("PACC") / Veterans Center - (sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Gazebo
1st Floor
1x4x 2L sm vapor tight, F32T8 32w, 6 6
electronic ballast
Rf#-20 Rm - Ext - Ceiling
Mount
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Building/Area: Main Building
1st Floor
CF and LED 1L rec can, CFS-23w, CF 22 22
ballast
Rf#-1 Rm - Main Entry
lobby /area
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
CF and LED 1L rec can, CFS-23w, CF 5 5
ballast
Rf#-2 Rm - M RR RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
CF and LED 1L rec can, CFS-23w, CF 5 5
ballast
Rf#-3 Rm - W RR RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
CF and LED 1L rec can, CFS-23w, CF 2 2
ballast
Rf#-4 Rm - Storage Rm
left of above
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
CF and LED 1L rec can, CFS-23w, CF 2 2
ballast
Rf#-5 Rm - Storage Rm
right of Cedar Rm
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-6 Rm - RA Rm left of 1x4x 1L fxt, F32T8 32w, electronic ballast 1 1 Cedar Rm
RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
CF and LED 1L rec can 6", CFS-23w, CF 8 8
ballast
Rf#-7 Rm - Auditorium RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
CF and LED 1L rec can 8", CFS-23w, CF 28 28
ballast
Rf#-8 Rm - Auditorium RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 8" trim ring extender
CF and LED 1L rec can 6", CFS-23w, CF 4 4
ballast
Rf#-9 Rm - Kitchen RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
CF and LED 1L rec can 6", CFS-23w, CF 2 2
ballast
Rf#-10 Rm - Kitchen RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-11 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
CF 1L wm wall pack small, CFP-26w, CF 4 4
ballast
Rf#-12 Rm - Ext - Wall
Mount
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
CF 2L wm wall pack small, CFP-26w, CF 2 2
ballast
Rf#-13 Rm - Ext - Wall
Mount
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
MH 1L wm wall pack large, MH 150W, 1 1
HID ballast
Rf#-14 Rm - Ext - Wall
Mount
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
Rf#-15 Rm - Ext - Wall LED 1L wm wall pack small, LED, n/a 0 Mount
DND - DND: (do not do, fixtures left as is)
Rf#-16 Rm - Ext - Wall LED 1L flood, trunion, LED, n/a 3 3 Mount
DND - DND: (do not do, fixtures left as is)
Rf#-17 Rm - Ext - Pole MH 1L cobra head, MH 400w, HID ballast 1 1 Mount
NL080/p/cbr - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 80w (Vly)
Rf#-18 Rm - Ext - Pole LED 1L cobra head, LED , n/a 5 5 Mount
DND - DND: (do not do, fixtures left as is)
Rf#-19 Rm - Ext - Pole LED 1L area light small, LED, n/a 2 2 Mount
DND - DND: (do not do, fixtures left as is)
Building/Area: Nutrition Center
1st Floor
CF and LED 2L wm sconce, CFS-23w R40, 8 8
CF ballast
Rf#-21 Rm - Main
Hallways
RL092/s/R40 - (2) LED 8w R40 screw in lamp, 4000K
CF and LED 1L rec can, CFS-23w, CF 4 4
ballast
Rf#-22 Rm - Main
Hallways
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
CF and LED 1L rec can, CFS-23w, CF 3 3
ballast
Rf#-23 Rm - Main
Hallways
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
CF and LED 1L rec can, CFS-23w, CF 3 3
ballast
Rf#-24 Rm - Main
Hallways
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-25 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Oak Rm Bldg
1st Floor
Rf#-26 Rm - Main Lobby CF 2L rec can, CFS-23w, CF ballast 8 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 8 rated life
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Park Avenue Community Center ("PACC") / Veterans Center Lighting Page 41 176 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Park Avenue Community Center ("PACC") / Veterans Center - (sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-27 Rm - B RR CF 2L rec can, CFS-23w, CF ballast 7 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 7 rated life
Rf#-28 Rm - B RR CF 2L rec can emr, CFS-23w, CF ballast 1 RL011/ckit/6e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life
Rf#-29 Rm - G RR CF 2L rec can, CFS-23w, CF ballast 7 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 7 rated life
Rf#-30 Rm - G RR CF 2L rec can emr, CFS-23w, CF ballast 1 RL011/ckit/6e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life
Rf#-31 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
for Park Avenue Community Center ("PACC") / Veterans Center : 145 145 W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Park Avenue Community Center ("PACC") / Veterans Center Lighting Page 42 177 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Police and Fire Headquarters ("PAFH") -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main
1st Floor
Rf#-1 Rm - Lobby CF 2L rec can 10", CFP-26w, CF ballast 11 RL011/ckit/8t10e - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000- 11 Hr L70 rated life, (1) 10" trim ring extender
Rf#-2 Rm - Lobby LED 2L rec can 10", LED , n/a 2 RL011/ckit/8t10e - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000- 2 Hr L70 rated life, (1) 10" trim ring extender
Rf#-3 Rm - Lobby LED 4L pm fxt, LED A19, n/a 2 DND - DND: (do not do, fixtures left as is) 2 Rf#-4 Rm - Lobby CF 4L pm deco fxt, CFS-26w, CF ballast 1 RL094/s - (4) LED 8.5w A19 screw in lamp, 4000K 1 Rf#-5 Rm - MRR CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4 1L Strip, F32T8 32w, electronic 2 2
ballast
Rf#-6 Rm - MRR RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-7 Rm - WRR CF 2L rec can 8", CFP-26w, CF ballast 1 RL011/ckit/6t8 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 8" trim ring extender
1x4 1L Strip, F32T8 32w, electronic 2 2
ballast
Rf#-8 Rm - WRR RLT841dw - (1) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-9 Rm - Reception CF 2L rec can 10", CFP-26w, CF ballast 28 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 28 L70 rated life, (1) 10" trim ring extender
Rf#-10 Rm - Reception LED 2L rec can 10", LED , n/a 4 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 4 L70 rated life, (1) 10" trim ring extender
Rf#-11 Rm - Reception LED 4L pm fxt, LED A19, n/a 2 DND - DND: (do not do, fixtures left as is) 2 2x4x 2L rec trf, F32T8 32w, electronic 3 3
ballast
Rf#-12 Rm - Hall RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-13 Rm - 109 Comm 2x2x 2L rec trf, LED, n/a 3 3
Meet
RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) 2x2x 2L rec trf, FB31T8 32w U6, 17 17
electronic ballast
Rf#-14 Rm - 109 Comm
Meet
RLT822Udwe - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000- Hr L70 rated life, remove existing ballast from service (SYL) Rf#-15 Rm - 109 Comm LED 2L rec can 10", LED, n/a 2 2
Meet
RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 10" trim ring extender
Rf#-16 Rm - 109 Comm CF 2L rec can 10", CFP-26w, CF ballast 18 18 Meet
RL011/ckit/8t10e - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000- Hr L70 rated life, (1) 10" trim ring extender
Rf#-17 Rm - 109 Comm LED 2L rec can 6", LED, n/a 1 1
Meet
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-18 Rm - 109 Comm CF 2L rec can 6", CFP-26w, CF ballast 3 3 Meet
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x4x 2L sm ind hood, F32T8 32w, 3 3
electronic ballast
Rf#-19 Rm - 105
Custodian
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L rec trf, F32T8 32w, electronic 1 1
ballast
Rf#-20 Rm - 108 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-21 Rm - 194 Lobby CF 2L rec can 6", CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
Rf#-22 Rm - Records CF 2L rec can 6", CFP-26w, CF ballast 1 1 Lobby
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-23 Rm - Records LED 2L rec can 6", LED, n/a 1 1
Lobby
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-24 Rm - Records CF 2L rec can 6", CFP-26w, CF ballast 5 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 5 rated life
Rf#-25 Rm - Records LED 2L rec can 6", LED, n/a 5 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 5 rated life
Rf#-26 Rm - Atrium CF 2L rec can 6", CFP-26w, CF ballast 10 RL011/ckit/6e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 10 L70 rated life
Rf#-27 Rm - Atrium LED 2L rec can 6", LED, n/a 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
1x4x 2L wm wall wash, F32T8 32w, 4 4
electronic ballast
Rf#-28 Rm - Main Hall RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L pm fxt, F32T8 32w, electronic 15 15
ballast
Rf#-29 Rm - Hall @ 151 RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-30 Rm - Hall @ 134 CF 2L rec can 6", CFP-26w, CF ballast 5 5 & 172
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Police and Fire Headquarters ("PAFH") Lighting Page 43 178 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Police and Fire Headquarters ("PAFH") -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-31 Rm - Hall @ 134 LED 2L rec can 6", LED, n/a 2 2
& 172
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
1x4x 2L pm fxt, F32T8 32w, electronic 3 3
ballast
Rf#-32 Rm - 169 RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L pm fxt, F32T8 32w, electronic 4 4
ballast
Rf#-33 Rm - 155 RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L pm fxt, F32T8 32w, electronic 5 5
ballast
Rf#-34 Rm - 121 RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-35 Rm - MRR @ 172 CF 2L rec can 6", CFP-26w, CF ballast 3 RL011/ckit/6e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 3 L70 rated life
Rf#-36 Rm - WRR CF 2L rec can 6", CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
Rf#-37 Rm - Hall @ 40 CF 2L rec can 6", CFP-26w, CF ballast 3 RL011/ckit/6e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 3 L70 rated life
Rf#-38 Rm - Hall @ 40 LED 2L rec can 6", LED, n/a 5 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 5 rated life
Rf#-39 Rm - 14 LED 2L rec can 6", LED, n/a 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
Rf#-40 Rm - 135 CF 2L rec can 6", CFP-26w, CF ballast 13 RL011/ckit/6e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 13 L70 rated life
Rf#-41 Rm - 135 LED 2L rec can 6", LED, n/a 5 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 5 rated life
Rf#-42 Rm - Ext - Ceiling CF 2L rec can 6", CFP-26w, CF ballast 13 13 Mount
RL011/ckit/6e - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
2nd Floor
Rf#-52 Rm - Hall @ 241 LED 2L rec can 10", LED, n/a 9 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 9 L70 rated life, (1) 10" trim ring extender
Rf#-53 Rm - Hall @ 241 CF 2L rec can 6", CFP-26w, CF ballast 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
Rf#-54 Rm - Hall @ 241 LED 2L rec can 6", LED, n/a 7 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 7 rated life
Rf#-55 Rm - Hall @ 241 CF 2L rec can 6", CFP-26w, CF ballast 7 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 7 rated life
Rf#-56 Rm - Atrium LED 2L rec can 6", LED, n/a 1 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 1 rated life
Rf#-57 Rm - Atrium CF 2L rec can 6", CFP-26w, CF ballast 14 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 14 rated life
Rf#-58 Rm - Hall @ 216 LED 2L rec can 6", LED, n/a 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
Rf#-59 Rm - Hall @ 216 CF 2L rec can 6", CFP-26w, CF ballast 6 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 6 rated life
Rf#-60 Rm - Locker 231 LED 2L rec can 6", LED, n/a 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
Rf#-61 Rm - Locker 231 CF 2L rec can 6", CFP-26w, CF ballast 9 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 9 rated life
Rf#-62 Rm - 231C Rest CF 2L rec can 10", CFP-26w, CF ballast 1 1 & Recover
RL011/ckit/8t10bt - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000- Hr L70 rated life, (1) 10" trim ring extender L-DS
Rf#-63 Rm - 231D Rest CF 2L rec can 10", CFP-26w, CF ballast 1 1 & Recover
RL011/ckit/8t10bt - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000- Hr L70 rated life, (1) 10" trim ring extender L-DS
Rf#-64 Rm - Locker 226 LED 2L rec can 6", LED, n/a 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
Rf#-65 Rm - Locker 226 CF 2L rec can 6", CFP-26w, CF ballast 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
Rf#-66 Rm - 226C Rest CF 2L rec can 10", CFP-26w, CF ballast 1 1 & Recover
RL011/ckit/8t10bt - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000- Hr L70 rated life, (1) 10" trim ring extender L-DS
Rf#-67 Rm - 226D Rest CF 2L rec can 10", CFP-26w, CF ballast 1 1 & Recover
RL011/ckit/8t10bt - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000- Hr L70 rated life, (1) 10" trim ring extender L-DS
Rf#-68 Rm - Hall @ 223 LED 2L rec can 6", LED, n/a 7 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 7 rated life
Rf#-69 Rm - Hall @ 223 CF 2L rec can 6", CFP-26w, CF ballast 10 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 10 rated life
Rf#-70 Rm - MRR CF 2L rec can 6", CFP-26w, CF ballast 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Police and Fire Headquarters ("PAFH") Lighting Page 44 179 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Police and Fire Headquarters ("PAFH") -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-71 Rm - WRR CF 2L rec can 6", CFP-26w, CF ballast 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
Rf#-72 Rm - 223 CF 2L rec can 6", CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
Rf#-73 Rm - 223A CF 2L rec can 6", CFP-26w, CF ballast 3 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 3 rated life
Rf#-74 Rm - Lobby @ LED 2L rec can 6", LED, n/a 6 6
205
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-75 Rm - Lobby @ CF 2L rec can 6", CFP-26w, CF ballast 6 6 205
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-76 Rm - WRR CF 2L rec can 6", CFP-26w, CF ballast 1 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 1 rated life
Rf#-77 Rm - MRR CF 2L rec can 6", CFP-26w, CF ballast 1 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 1 rated life
Rf#-78 Rm - 205 Chief CF 2L rec can 10", CFP-26w, CF ballast 10 10 Conf
RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 10" trim ring extender
Rf#-79 Rm - 205 Chief LED 2L rec can 10", LED, n/a 6 6
Conf
RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life, (1) 10" trim ring extender
2x2x 2L rec trf, FB31T8 32w U6, 12 12
electronic ballast
Rf#-80 Rm - 205 Chief
Conf
RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) Rf#-81 Rm - 295 CF 2L rec can 6", CFP-26w, CF ballast 1 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 1 rated life
Rf#-82 Rm - 296 CF 2L rec can 6", CFP-26w, CF ballast 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
Rf#-83 Rm - 296 RR CF 2L rec can 6", CFP-26w, CF ballast 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
Rf#-84 Rm - Hall @ 289 LED 2L rec can 10", LED, n/a 2 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 2 L70 rated life, (1) 10" trim ring extender
Rf#-85 Rm - Hall @ 259 CF 2L rec can 6", CFP-26w, CF ballast 6 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 6 rated life
Rf#-86 Rm - Hall @ 259 LED 2L rec can 6", LED, n/a 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
Rf#-87 Rm - 234 CF 2L rec can 10", CFP-26w, CF ballast 9 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 9 L70 rated life, (1) 10" trim ring extender
Rf#-88 Rm - 234 LED 2L rec can 10", LED, n/a 1 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 1 L70 rated life, (1) 10" trim ring extender
1x4x 2L pm fxt, F32T8 32w, electronic 6 6
ballast
Rf#-89 Rm - 249 RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L pm fxt, F32T8 32w, electronic 10 10
ballast
Rf#-90 Rm - Main Hall RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
3rd Floor
Rf#-91 Rm - Atrium CF 2L rec can 6", CFP-26w, CF ballast 7 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 7 rated life
Rf#-92 Rm - Atrium LED 2L rec can 6", LED, n/a 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
Rf#-93 Rm - Atrium MH 1L flood, CMH 300W, HID ballast 8 8 (tower flood)
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Rf#-94 Rm - 319 Locker CF 2L rec can 6", CFP-26w, CF ballast 8 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 8 rated life
Rf#-95 Rm - 319 Locker LED 2L rec can 6", LED, n/a 1 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 1 rated life
Rf#-96 Rm - Hall @ 310 CF 2L rec can 6", CFP-26w, CF ballast 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
Rf#-97 Rm - Hall @ 310 LED 2L rec can 6", LED, n/a 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
Rf#-98 Rm - 318 Locker CF 2L rec can 6", CFP-26w, CF ballast 9 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 9 rated life
Rf#-99 Rm - Hall @ 323 CF 2L rec can 6", CFP-26w, CF ballast 12 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 12 rated life
Rf#-100 Rm - Hall @ 323 LED 2L rec can 6", LED, n/a 9 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 9 rated life
Rf#-101 Rm - 309 CF 2L rec can 6", CFP-26w, CF ballast 6 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 6 rated life
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Police and Fire Headquarters ("PAFH") Lighting Page 45 180 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Police and Fire Headquarters ("PAFH") -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-102 Rm - 309 LED 2L rec can 6", LED, n/a 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
1x4x 2L pm fxt, F32T8 32w, electronic 3 3
ballast
Rf#-103 Rm - 309 RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-104 Rm - 306 CF 2L rec can 6", CFP-26w, CF ballast 5 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 5 rated life
Rf#-105 Rm - Lobby CF 2L rec can 10", CFP-26w, CF ballast 11 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 11 L70 rated life, (1) 10" trim ring extender
Rf#-106 Rm - Lobby LED 2L rec can 10", LED, n/a 8 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 8 L70 rated life, (1) 10" trim ring extender
Rf#-107 Rm - WRR CF 2L rec can 6", CFP-26w, CF ballast 1 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 1 rated life
Rf#-108 Rm - MRR CF 2L rec can 6", CFP-26w, CF ballast 1 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 1 rated life
Rf#-109 Rm - 349 Conf CF 2L rec can 10", CFP-26w, CF ballast 14 RL011/ckit/8t10 - (1) LED 8" rec can kit, 4000K, 11w, 120/277, 50,000-Hr 14 L70 rated life, (1) 10" trim ring extender
2x2x 2L rec trf, FB31T8 32w U6, 12 12
electronic ballast
Rf#-110 Rm - 349 Conf RLT822Udw - (2) 2' LED T8 "U" lamp 15w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service (SYL) Rf#-111 Rm - Open Area CF 2L rec can 6", CFP-26w, CF ballast 9 9 @ 349
RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 rated life
Rf#-112 Rm - 346 CF 2L rec can 6", CFP-26w, CF ballast 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
Rf#-113 Rm - 347 CF 2L rec can 6", CFP-26w, CF ballast 10 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 10 rated life
1x4x 2L pm fxt, F32T8 32w, electronic 3 3
ballast
Rf#-114 Rm - 348 RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-115 Rm - 344 CF 2L rec can 6", CFP-26w, CF ballast 2 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 2 rated life
Rf#-116 Rm - 339 CF 2L rec can 6", CFP-26w, CF ballast 1 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 1 rated life
Rf#-117 Rm - 338 CF 2L rec can 6", CFP-26w, CF ballast 1 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 1 rated life
Rf#-118 Rm - 332 CF 2L rec can 6", CFP-26w, CF ballast 4 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 4 rated life
Rf#-119 Rm - EOC CF 2L rec can 6", CFP-26w, CF ballast 14 RL011/ckit/6 - (1) LED 6" rec can kit, 4000K, 11w, 120/277, 50,000-Hr L70 14 rated life
1x4x 2L pm fxt, F32T8 32w, electronic 3 3
ballast
Rf#-120 Rm - EOC RLT842dwe - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Building/Area: Public Parking
1st Floor
Rf#-43 Rm - Ext - Pole LED 1L SB SqP black, LED CC, n/a 18 18 Mount
DND - DND: (do not do, fixtures left as is)
MH 1L SB SqP black, MH 250W, HID 4 4
ballast
Rf#-44 Rm - Ext - Pole
Mount
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Rf#-45 Rm - Ext - Pole HPS 1L flood, adj, MH 100W, HID ballast 6 6 Mount
NL040/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 40w (Vly) oemB
Building/Area: Staff Parking
1st Floor
Rf#-46 Rm - Ext - Pole LED 1L SB SqP black, LED CC, n/a 7 7 Mount
DND - DND: (do not do, fixtures left as is)
MH 1L SB SqP black, MH 250W, HID 1 1
ballast
Rf#-47 Rm - Ext - Pole
Mount
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Rf#-48 Rm - Ext - Pole HPS 1L flood, adj, MH 100W, HID ballast 6 6 Mount
NL040/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 40w (Vly) oemB
Rf#-49 Rm - Ext - Pole LED 1L SB SqP BZ, LED CC, n/a 4 4 Mount
DND - DND: (do not do, fixtures left as is)
MH 1L wall pack small Hz, MH 100W, 3 3
HID ballast
Rf#-50 Rm - Ext - Wall
Mount
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
LED 1L wm wall pack small Hz, LED CC, 12 12
n/a
Rf#-51 Rm - Ext - Wall
Mount
DND - DND: (do not do, fixtures left as is)
Qty for Police and Fire Headquarters ("PAFH") : 645 645 W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Police and Fire Headquarters ("PAFH") Lighting Page 46 181 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Ranger Station - Dixon Lake -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Camp Area 2-5
1st Floor
MV 1L wm wall pack, MV 175W, HID 1 1
ballast
Rf#-26 Rm - RR Bldg NL028/wp/ft/wg - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
1x4x 4L sm wp, F32T8 32w, electronic 2 2
ballast
Rf#-27 Rm - RR Bldg
Chase
RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Building/Area: Camp Area 26-29
1st Floor
MV 1L wm wall pack, MV 175W, HID 3 3
ballast
Rf#-30 Rm - RR Bldg NL028/wp/ft/wg - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
1x4x 4L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-31 Rm - RR Bldg
Chase
RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Building/Area: Camp Area 35-44
1st Floor
MV 1L wm wall pack, MV 175W, HID 3 3
ballast
Rf#-32 Rm - RR Bldg NL028/wp/ft/wg - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
1x4x 2L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-33 Rm - RR Bldg
Chase
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Building/Area: Camp Area 9-25
1st Floor
MV 1L wm wall pack, MV 175W, HID 3 3
ballast
Rf#-28 Rm - RR Bldg NL028/wp/ft/wg - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
1x4x 4L sm wp, F32T8 32w, electronic 1 1
ballast
Rf#-29 Rm - RR Bldg
Chase
RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Building/Area: Gate House
1st Floor
Rf#-1 Rm - Ext - Wall LED 1L wm wall pack, LED, n/a 2 2 Mount
DND - DND: (do not do, fixtures left as is)
Building/Area: Hilltop Area
1st Floor
Rf#-5 Rm - Ext - Pole LED 1L post top, LED, n/a 5 5
Mount
DND - DND: (do not do, fixtures left as is)
MV 1L wm wall pack, MV 175W, HID 3 3
ballast
Rf#-6 Rm - RR NL028/wp/ft/wg - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
1x4x 2L sm ind hood, F32T8 32w, 1 1
electronic ballast
Rf#-7 Rm - Chase RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-8 Rm - Yuuca Shelter CF 1L socket E26, CFS-15w, CF ballast 2 RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K 2 MV 1L wm wall pack, MV 175W, HID 4 4
ballast
Rf#-9 Rm - Poppy
Shelter
NL028/wp/ft/wg - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
Building/Area: Lakeshore Area
1st Floor
MV 1L wm wall pack, MV 175W, HID 6 6
ballast
Rf#-10 Rm - Main NL028/wp/ft/wg - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
1x4x 2L sm vapor tight, F32T8 32w, 2 2
electronic ballast
Rf#-11 Rm - Main RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm vapor tight, F32T8 32w, 1 1
electronic ballast
Rf#-12 Rm - Electrical RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-13 Rm - Fish 1x4x 1L fxt, LED, n/a 2 2
Cleaning
DND - DND: (do not do, fixtures left as is)
1x4x 2L rec trf, F32T8 32w, electronic 10 10
ballast
Rf#-14 Rm - Concession RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-15 Rm - Shelter 1 CF 1L socket E26, CFS-15w, CF ballast 2 RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K 2 Rf#-16 Rm - Shelter 2 CF 1L socket E26, CFS-15w, CF ballast 2 RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K 2 W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Ranger Station - Dixon Lake Lighting Page 47 182 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Ranger Station - Dixon Lake -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Rf#-17 Rm - Shelter 3 CF 1L socket E26, CFS-15w, CF ballast 2 RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K 2 Rf#-18 Rm - Shelter 4 LED 1L wm wall pack, LED CC, n/a 4 DND - DND: (do not do, fixtures left as is) 4 Rf#-19 Rm - Left Dock MH 1L post top, MH 150W, HID ballast 3 RL0341/s/mg - (1) LED 34w A21 style screw in lamp, 120/277, 50,000-Hr 3 rated life, 5000K, mogul base
Rf#-20 Rm - Middle LED 1L area lights, LED, n/a 2 2
Dock Bldg
DND - DND: (do not do, fixtures left as is)
Rf#-21 Rm - Middle 1x4x 2L sm strip, LED, n/a 2 2
Dock Bldg
DND - DND: (do not do, fixtures left as is)
1x4x 2L sm strip, F32T8 32w, electronic 1 1
ballast
Rf#-22 Rm - Middle
Dock Bldg
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 4L sm wp, F32T8 32w, electronic 8 8
ballast
Rf#-23 Rm - Beach
House
RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-24 Rm - Beach CF 1L Jelly Jar, CFS-42W, CF ballast 5 5 House
NL012/wp/rb - New LED wall pack full, 50,000-Hr L70 rated life, 12w, built in 120/277v photo cell (Rb)
Rf#-25 Rm - Brick Cabin DND (do not do, left as is), LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 Building/Area: Maint Shed
1st Floor
1x8x 2L pm ind hood, F96T8 96W, 4 4
magnetic ballast
Rf#-2 Rm - Interior NL055/8s - New 8' LED surface mount narrow wrap, 50,000-Hr L70 rated life, 55w, 4000K (ALE)
Rf#-3 Rm - Ext - Pole LED 1L post top, LED, n/a 1 1
Mount
DND - DND: (do not do, fixtures left as is)
Building/Area: Trailer
1st Floor
Rf#-4 Rm - Interior DND (do not do, left as is), LED ?w, n/a DND - DND: (do not do, fixtures left as is) 0 Qty for Ranger Station - Dixon Lake : 89 89
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Ranger Station - Dixon Lake Lighting Page 48 183 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Recycling Offices -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Main Building
1st Floor
Rf#-10 Rm - Ext-Bldg Inc. 1L fxt, Inc. 60w, n/a 1 1
Mnt (wall)
RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K
Building/Area: New Building
1st Floor
Rf#-9 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Orginal Office Trailer
1st Floor
2x4x 4L rec trf, F40T12 34w, magnetic 2 2
ballast
Rf#-1 Rm - Entry Lobby RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-2 Rm - RR Inc. 1L fxt, Inc. 60w, n/a 1 RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K 1 2x4x 4L rec trf, F40T12 34w, magnetic 3 3
ballast
Rf#-3 Rm - Office #1 RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 4L rec trf, F40T12 34w, magnetic 1 1
ballast
Rf#-4 Rm - Office #2 RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
2x4x 4L rec trf, F40T12 34w, magnetic 2 2
ballast
Rf#-5 Rm - Office #3 RLT844dw - (4) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-6 Rm - Office #3 2x4x 2L rec trf, LED ?w TLED, n/a 1 RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 1 rated life, remove existing ballast from service
Rf#-7 Rm - Ext-Bldg Mnt Inc. 1L fxt, Inc. 60w, n/a 1 1
(wall)
RL091/s - (1) LED 8.5w A19 screw in lamp, 4000K
Rf#-8 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Qty for Recycling Offices : 12 12
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Recycling Offices Lighting Page 49 184 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Rod McLeod Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: RR Building
1st Floor
Rf#-1 Rm - B RR DND (do not do, left as is), TLED, n/a DND - DND: (do not do, fixtures left as is) 0 Rf#-2 Rm - G RR DND (do not do, left as is), TLED, n/a DND - DND: (do not do, fixtures left as is) 0 (est) 1x4x 2L sm strip, F32T8 32w, 1 1
electronic ballast
Rf#-3 Rm -
custodial/chase
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
HPS 1L wm wall pack FT, HPS 100w, HID 1 1
ballast
Rf#-4 Rm - Ext-Bldg Mnt
(walls) (backside)
NL028/wp/fc - New LED wall pack (FCO), 50,000-Hr L70 rated life, 28w (MAX)
HPS 1L wm wall pack FT, HPS 100w, HID 1 1
ballast
Rf#-5 Rm - Ext-Bldg Mnt
(walls)
NL028/wp/ft - New LED wall pack (FT), 50,000-Hr L70 rated life, 28w (MAX)
Rf#-6 Rm - Ext-Pole Mnt LED 1L shoe box, LED ?w CC, n/a 1 DND - DND: (do not do, fixtures left as is) 1 Qty for Rod McLeod Park : 4 4
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Rod McLeod Park Lighting Page 50 185 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Ryan Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: Parking Lots
1st Floor
Rf#-2 Rm - Ext-Pole Mnt LPS 1L SB SqP, DB, LPS 180w, HID ballast 13 13 (West Lot)
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Rf#-3 Rm - Ext-Pole Mnt LPS 1L SB SqP, DB, LPS 135w, HID ballast 2 2 (South)
NL070/p/s - New LED area light, pole or bldg. mount, 50,000-Hr L70 rated life, 70w (Vly) oemB
Rf#-4 Rm - Ext-Pole Mnt DND (do not do, left as is), LED 60w, n/a 18 18 (South)
DND - DND: (do not do, fixtures left as is)
Building/Area: RR Building
1st Floor
Rf#-5 Rm - RR entry area CF 1L wm jelly jar, CFP-26w, CF ballast 8 RL091/s/sk - (1) LED 8.5w A19 screw in lamp, 4000K, (1) new lamp socket 8 Rf#-6 Rm - Small Family CF 1L wm jelly jar, CFP-26w, CF ballast 4 4 RR
RL091/s/sk - (1) LED 8.5w A19 screw in lamp, 4000K, (1) new lamp socket Rf#-7 Rm - B RR CF 1L wm jelly jar, CFP-26w, CF ballast 8 RL091/s/sk - (1) LED 8.5w A19 screw in lamp, 4000K, (1) new lamp socket 8 Rf#-8 Rm - W RR CF 1L wm jelly jar, CFP-26w, CF ballast 8 RL091/s/sk - (1) LED 8.5w A19 screw in lamp, 4000K, (1) new lamp socket 8 (est) 1x4x 2L sm wp, F32T8 32w, 2 2
electronic ballast
Rf#-9 Rm - Custodial RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
(est) 1x4x 2L sm wp, F32T8 32w, 4 4
electronic ballast
Rf#-10 Rm - Grounds
Rm #1
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
(est) 1x4x 2L sm wp, F32T8 32w, 4 4
electronic ballast
Rf#-11 Rm - Grounds
Rm #2
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-12 Rm - Ext-BLdg HPS 1L sm square, HPS 100w, HID ballast 9 9 Mnt (eaves)
NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) Rf#-13 Rm - Ext-BLdg LED 1L sm square, LED ?w, n/a 1 1
Mnt (eaves)
NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) Building/Area: Snack Building
1st Floor
(est) 1x4x 2L sm wp, F32T8 32w, 6 6
electronic ballast
Rf#-14 Rm - Snack Room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
(est) 1x4x 2L sm wp, F32T8 32w, 4 4
electronic ballast
Rf#-15 Rm - Storage
Room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
(est) 1x4x 2L sm wp, F32T8 32w, 3 3
electronic ballast
Rf#-16 Rm - ? Room RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-17 Rm - Ext-BLdg HPS 1L sm square, HPS 100w, HID ballast 9 9 Mnt (eaves)
NL020/sq - New LED surface mnt sq., 50,000-Hr L70 rated life, 20w (ALE) Building/Area: Sports Fields
1st Floor
DND (do not do, left as is), MUSCO LED, 0
n/a
Rf#-1 Rm - All Sports
Fields
DND - DND: (do not do, fixtures left as is)
Qty for Ryan Park : 103 103
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Ryan Park Lighting Page 51 186 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Washington Park -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: All Buildings
1st Floor
Rf#-1 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-2 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Parks Spaces
1st Floor
LPS 1L post top china hat (luis poulsen), 11 11
LPS 55w, HID ballast
Rf#-3 Rm - Ext-Pole Mnt
(walkways and area)
RL0451/s/mg - (1) LED 45w corn cob style screw in lamp, 120/277, 50,000-Hr rated life, 5000K, mogul base
Rf#-4 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Exterior Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Sports Fields
1st Floor
DND (do not do, left as is), MUSCO LED, 0
n/a
Rf#-5 Rm - All Sports
Fields
DND - DND: (do not do, fixtures left as is)
Qty for Washington Park : 11 11
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Washington Park Lighting Page 52 187 Item5.
Location Existing Fixture Description Qty Retrofit Code Description (Ltg Control in RED)
PRE-RETROFIT POST RETROFIT
Qty
Water Treatment Plant ("WTP") -
(sorted by building, floor, area)
City of Escondido - Lighting Detail Report
Building/Area: All other Buildings
1st Floor
Rf#-13 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-14 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: Operations Building
Downstairs
1x8x 2L pm ind hood, F96T12 60w, 8 8
magnetic ballast
Rf#-3 Rm - Pump Area NL055/8s - New 8' LED surface mount narrow wrap, 50,000-Hr L70 rated life, 55w, 4000K (ALE)
Rf#-4 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
Rf#-5 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Upstairs
Rf#-1 Rm - All Interior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Rf#-2 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Building/Area: OSG Bldg
1st Floor
HPS 1L vapor jar Exp (plug in), HPS 150w, 16 16
HID ballast
Rf#-6 Rm - Sodium
Hypochlorite Rm
NL060/exp - New LED surface mnt dome., 50,000-Hr L70 rated life, 60w (Rb)
1x4x 2L sm vapor tight, F40T12 34w, 4 4
magnetic ballast
Rf#-7 Rm - electrical
room
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm vapor tight, F32T8 32w, 2 2
electronic ballast
Rf#-8 Rm - storage RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm vapor tight, F32T8 32w, 8 8
electronic ballast
Rf#-9 Rm - gym RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
1x4x 2L sm vapor tight, F32T8 32w, 8 8
electronic ballast
Rf#-10 Rm - Motor
control room (MCC)
RLT842dw - (2) 4' LED T8 lamp 10.5w, Type B, direct wire, 50,000-Hr L70 rated life, remove existing ballast from service
Rf#-11 Rm - All other DND (do not do, left as is), LED ?w, n/a 0 Interior Space
DND - DND: (do not do, fixtures left as is)
Rf#-12 Rm - All Exterior DND (do not do, left as is), LED ?w, n/a 0 Space
DND - DND: (do not do, fixtures left as is)
Qty for Water Treatment Plant ("WTP") : 46 46
W* = wall switch sensor; C* = ceiling sensor; E* = existing sensor, L* Dimming Control Water Treatment Plant ("WTP") Lighting Page 53 188 Item5.
Attachment “D”
Mechanical Equipment Schedule
189
Item5.
Central Plant - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Central Plant Cooling Tower - Single Cell Evapco USS29024 4107528 2006 Refurbish2 Central Plant CT Fan - Motor WorldWide Elect. PEWWE10-12-256T 1018071V XP0 10 hp / 1175 rpm 2006 208/230-3-60 Y 91.0% Efficiency3 Central Plant Cooling Tower - Single Cell 2006 Refurbish4 Central Plant CT Fan - Motor Toshiba B0106FLF2USH02 40504550 10 hp / 1175 rpm 2006 208/230-3-60 Y 92.4% Efficiency5 Central Plant Cooling Tower - Single Cell 2006 Refurbish6 Central Plant CT Fan - Motor Weg W22 CC029A 13OUT22 1076247105 5 hp / 1170 rpm 2006 208/230-3-60 Y 89.5% Efficiency7 Central Plant CW Pump 1 Bell & Gossett 1510 BFS 0015989-01 C60 15 HP / 985 gpm / 38 ft-hd 2006 Y8 Central Plant CW Pump 2 Bell & Gossett 1510 BFS 0015989-01 C60 15 HP / 985 gpm / 38 ft-hd 2006 Y9 Central Plant CW Pump 1 - Motor Weg CC029A 27OUT15 PF84735 15 hp / 1180 rpm 2006 208/230-3-60 Y 91.7% Efficiency 10 Central Plant CW Pump 2 - Motor Weg CC029A 27OUT15 PF84735 15 hp / 1180 rpm 2006 208/230-3-60 Y 91.7% Efficiency11 Central Plant CW Pump 3 7.5 HP/ 486 gpm / 36 ft-hd 2006 Y Info based on As-Built / tag missing.12 Central Plant CW Pump 3 - Motor US Motor AE47 UJ10S1AM 10 hp / 3505 rpm 2006 208/230-3-60 Y 88.5% Efficiency13 Central Plant NG Driven Chiller 1 Tecochill CH350-X 20161 350 tons 2006 460-3-60 Y Replace with mag. bearing14 Central Plant NG Driven Chiller 2 Tecochill CH350-X 20161 350 tons 2006 460-3-60 Y Replace with mag. bearing15 Central Plant NG Driven Chiller - - - 2006 Y16 Central Plant DX Chiller 4 Trane CGAFC604AKA C06A00606 60 tons 2006 460-3-60 Y17 Central Plant Primary CHW Pump 3 Bell & Gossett 1510 BFS C016004-01 C60 3 HP / 164 gpm / 35 ft-hd 2006 Y18 Central Plant Primary CHW Pump 3 - Motor Weg 3 HP / 1760 rpm 2006 Y19 Central Plant Primary CHW Pump 4 Bell & Gossett 1510 BFS C015986-01 C60 3 HP / 130 gpm / 35 ft-hd 2006 Y20 Central Plant Primary CHW Pump 4 - Motor Weg CC029A 07JUL05 BS38645 3 hp / 1760 rpm 2006 208/230-3-60 Y 89.5% Efficiency21 Central Plant Primary CHW Pump 1 Bell & Gossett 1510 BFS 4BC C015969 01 C60 5 HP / 373 gpm / 35 ft-hd 2006 Y22 Central Plant Primary CHW Pump 1 - Motor Weg CC029A 31MAI05 BR83614 5 hp / 1160 rpm 2006 208/230-3-60 Y 89.5% Efficiency23 Central Plant Primary CHW Pump 2 Bell & Gossett 1510 BFS 4BC C015969 01 C60 5 HP / 373 gpm / 35 ft-hd 2006 Y24 Central Plant Primary CHW Pump 2 - Motor Weg CC029A 31MAI05 BR83614 5 hp / 1160 rpm 2006 208/230-3-60 Y25 Central Plant Secondary CHW Pump 5 Bell & Gossett 1510 CO15988-02C60 40 HP / 580 gpm/140 ft-hd 2006 Y26 Central Plant Secondary CHW Pump 6 Bell & Gossett 1510 CO15988-02C60 40 HP / 580 gpm/140 ft-hd 2006 Y27 Central Plant Secondary CHW Pump 5 - Motor Weg W40 CC029A 1079227712 40 hp / 1775 rpm 2006 208/230-3-60 Y Reuse VFD28 Central Plant Secondary CHW Pump 6 - Motor Weg W40 CC029A 1079227712 40 hp / 1775 rpm 2006 208/230-3-60 Y Reuse VFD31 Central Plant HHW Pump 1 Taco 11-30121 01D003030Z B 320 gpm / 104 ft-hd 2006 Y32 Central Plant HHW Pumps 2 Taco 11-30121 01D003030Z B 320 gpm / 104 ft-hd 2006 Y33 Central Plant HHW Pump 1 - Motor Nidec FP86 Y 06 768557-001 M 0023 15 hp / 1775 rpm 2006 208/230-3-60 Y 93.0% Efficiency34 Central Plant HHW Pump 2 - Motor Nidec FP86 Y 06 768557-001 M 0023 15 hp / 1775 rpm 2006 208/230-3-60 Y 93.0% Efficiency35 Central Plant HX Pump Bell & Gossett RL-75 18L084 C50 2006 N Demo w/ Heat Recovery System36 Central Plant HX Pump Bell & Gossett RL-75 18L084 C50 2006 N Demo w/ Heat Recovery System37 Central Plant HX Pump Bell & Gossett RL-75 18L084 C50 2006 N Demo w/ Heat Recovery System38 Central Plant HX Pump - Motor Baldor 3 hp 2006 N Demo w/ Heat Recovery System39 Central Plant HX Pump - Motor Baldor 3 hp 2006 N Demo w/ Heat Recovery System40 Central Plant HX Pump - Motor Baldor 3 hp 2006 N Demo w/ Heat Recovery System ID#
Existing Equipment
190
Item5.
City Hall - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
3 City Hall Packaged Heat Pump Carrier 50TFQ012---601GA 0101G30305 10 2001 460-3-60 Side N Y 10 City Hall DX Chiller Trane CGAFC404AGA10000F000… C02H07353 40 2002 460-3-60 Side N Y14 City Hall Split Sys Heat Pump Arcoaire HHP224AK-- L020378777 2 2002 208/230-1-60 Down N Y15 City Hall Split Sys Heat Pump Mitsubishi PUH24EK 7XE00065A 2 2007 208/230-1-60 Down N Y ID#
Existing Equipment
191
Item5.
Don E. Anderson - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Don E. Anderson Packaged Heat Pump Trane WCH048F100AA 7385JKS3H 4 2007 208/230-1-60 Side N Y2 Don E. Anderson Packaged Heat Pump Trane WCH048F100AA 7391JJU3H 4 2007 208/230-1-60 Side N Y ID#
Existing Equipment
192
Item5.
EVCC - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
6 EVCC Packaged Gas / Elec Trane YHC060E3RLA0Z000000000000 104710652L 5 2010 208/230-3-60 Down Y Y7 EVCC Packaged Gas / Elec Trane YHC060E3RLA0Z000000000000 104710660L 5 2010 208/230-3-60 Down Y Y 11 EVCC Packaged Gas / Elec Trane YHC060E3RLA10000000000000 104710668L 5 2010 208/230-3-60 Down Y Y12 EVCC Packaged Gas / Elec Trane YHC060E3RLA10000000000000 104710676L 5 2010 208/230-3-60 Down Y Y20 EVCC Packaged Gas / Elec Trane YHC060E3RLA0Z000000000000 104710684L 5 2010 208/230-3-60 Down Y Y ID#
Existing Equipment
193
Item5.
Fire Station 1 - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Fire Station 1 Packaged Gas / Elec Carrier 48HJM004---541-- 3608G30458 3 2008 208/230-3-60 Side N Y Replacing with Pkg HP.2 Fire Station 1 Packaged Gas / Elec Carrier 48HJD007---551-- 3808G50516 6 2008 208/230-3-60 Side N Y Replacing with Pkg HP.3 Fire Station 1 Packaged Gas / Elec Carrier 48HJL006--541-- 3808G40303 5 2008 208/230-3-60 Side N Y Replacing with Pkg HP.4 Fire Station 1 Packaged Gas / Elec Carrier 48HJD007---551-- 3808G50525 6 2008 208/230-3-60 Side N Y Replacing with Pkg HP.5 Fire Station 1 Packaged Gas / Elec Carrier 48HJL005--551-- 4308G20372 4 2008 208/230-3-60 Side N Y Replacing with Pkg HP.6 Fire Station 1 Packaged Gas / Elec Carrier 48HJL006---541-- 3808G40301 5 2008 208/230-3-60 Side N Y Replacing with Pkg HP.8 Fire Station 1 Packaged Gas / Elec Carrier 48HJD012---571-- 4208G11513 10 2008 208/230-3-60 Side Y Y Replacing with Pkg HP. Add Power Exhaust9 Fire Station 1 Packaged Gas / Elec Carrier 48HJL006---541-- 3808G40302 5 2008 208/230-3-60 Side Y Y Replacing with Pkg HP.
ID#
Existing Equipment
194
Item5.
Fire Station 2 - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Fire Station 2 Split Sys Heat Pump York E1FB024S06A ELAM385651 2 1992 208/230-1-60 Down N Y2 Fire Station 2 Split Sys Furnace York ------A030S06A EHAM322209 2.5 1992 208/230-1-60 N Y Replacing w/ SS Heat Pump.3 Fire Station 2 Split Sys Furnace York H1------------ EHAM310560 3 1992 208/230-1-60 N Y Replacing w/ SS Heat Pump.4 Fire Station 2 Split Sys Furnace York H1DA036S0-- EHAM310558 3 1992 208/230-1-60 N Y Replacing w/ SS Heat Pump.5 Fire Station 2 Split Sys Furnace York H1DA048S25A ECAM083743 4 1992 208/230-3-60 N Y Replacing w/ SS Heat Pump.
ID#
Existing Equipment
195
Item5.
Fire Station 3 - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
2 Fire Station 3 Packaged Gas / Elec Carrier 48HJM006---541-- 4807G30241 5 2007 208/230-3-60 Down Y Y Replacing with Pkg HP.3 Fire Station 3 Packaged Gas / Elec Carrier 48HJM005---551-- 4807G30321 4 2007 208/230-3-60 Down Y Y Replacing with Pkg HP.4 Fire Station 3 Packaged Gas / Elec Carrier ------244 4 2007 208/230-3-60 Down Y Y Replacing with Pkg HP.6 Fire Station 3 Packaged Gas / Elec Carrier 48HJN004---541 4807G40245 3 2007 208/230-3-60 Down Y Y Replacing with Pkg HP.7 Fire Station 3 Packaged Gas / Elec Carrier 48HJM005---551-- 4807G20295 4 2007 208/230-3-60 Down Y Y Replacing with Pkg HP.
ID#
Existing Equipment
196
Item5.
Fire Station 5 - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Fire Station 5 Split Sys Heat Pump Trane TWR024C100A4 P275YYAFF 2 1999 208/230-1-60 Down N Y Air Handler Info: Trane, Model # TWG025A140B0, SN: P144U3R1Y2 Fire Station 5 Split Sys Furnace Rheem RAND-024JAZ 7293 M1707 06674 2 2007 208/230-1-60 N Y Replace w/ SS Heat Pump.3 Fire Station 5 Split Sys Furnace Rheem RAND-036JAZ 7297 M4607 03887 3 2007 208/230-1-60 N Y Replace w/ SS Heat Pump.4 Fire Station 5 Split Sys Furnace Rheem RAND-048JAZ 7303 M4307 05133 4 2007 208/230-1-60 N Y Replace w/ SS Heat Pump.
ID#
Existing Equipment
197
Item5.
Fire Station 6 - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Fire Station 6 Packaged Gas / Elec York ZJ048S10N2BAA1C N0D8788643 4 2008 208/230-3-60 Down Y Y Replacing with Pkg HP.2 Fire Station 6 Packaged Gas / Elec York ZJ048S10N2BAA1C N0D8788644 4 2008 208/230-3-60 Down Y Y Replacing with Pkg HP.3 Fire Station 6 Packaged Gas / Elec York ZJ036S08N2BAA1C N0D8788641 3 2008 208/230-3-60 Down Y Y Replacing with Pkg HP.5 Fire Station 6 Packaged Gas / Elec York ZJ036S08N2BAA1C N0D8788642 3 2008 208/230-3-60 Down Y Y Replacing with Pkg HP.
ID#
Existing Equipment
198
Item5.
Fire Station 7 - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Fire Station 7 Packaged Gas / Elec York DJ048N10N2AAA2B N0D8765886 4 2008 208/230-3-60 Down Y Y Replacing with Pkg HP.2 Fire Station 7 Packaged Gas / Elec York DJ036N08N2AAA2A N0H7151819 3 2007 208/230-3-60 Down Y Y Replacing with Pkg HP.4 Fire Station 7 Packaged Gas / Elec York DJ036N08N2AAA2A N0G7098876 3 2007 208/230-3-60 Down Y Y Replacing with Pkg HP.5 Fire Station 7 Packaged Gas / Elec York DJ048N10N2AAA2B N0D8765885 4 2008 208/230-3-60 Down Y Y Replacing with Pkg HP.7 Fire Station 7 Packaged Gas / Elec York DJ060N08N2AAA3A N0M7443423 5 2008 208/230-3-60 Down Y Y Replacing with Pkg HP.
ID#
Existing Equipment
199
Item5.
Mathes Community Center - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
2 Mathes Commnuity Center Packaged Gas / Elec Rheem Illegible Illegible 2 1996 208/230-3-60 Down Y Y Replacing with Pkg HP.3 Mathes Commnuity Center Packaged Gas / Elec Rheem Illegible Illegible 3 1996 208/230-3-60 Down Y Y Replacing with Pkg HP.4 Mathes Commnuity Center Packaged Gas / Elec Rheem RKKA-A060CL105 1X5643ADAAF429613796 5 1996 208/230-3-60 Down Y Y Replacing with Pkg HP.5 Mathes Commnuity Center Packaged Gas / Elec Rheem Illegible Illegible 3 1996 208/230-3-60 Down Y Y Replacing with Pkg HP.6 Mathes Commnuity Center Packaged Gas / Elec Rheem Illegible Illegible 5 1996 208/230-3-60 Down Y Y Replacing with Pkg HP.8 Mathes Commnuity Center Packaged Gas / Elec Rheem Illegible Illegible 5 1996 208/230-3-60 Down Y Y Replacing with Pkg HP.9 Mathes Commnuity Center Packaged Gas / Elec Rheem Illegible Illegible 5 1996 208/230-3-60 Down Y Y Replacing with Pkg HP.
ID#
Existing Equipment
200
Item5.
Oak Hill Activity Center - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Oak Hill Activity Center Mini Split Mitsubishi MUH09NW 8000380T 0.75 2008 115-1-60 N Y Indoor unit was not accessible - Add Vandal proof cage2 Oak Hill Activity Center Split Sys Furnace Carrier 538ANX0600000B 1701X0890198 5 2001 208/230-1-60 N Y Furnace: Carrier # 350MAV060080 / Replace with SS Heat Pump ID#
Existing Equipment
201
Item5.
Public Works Yard - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Public Works Yard Split Sys Furnace Illegible Illegible Illegible 3 >15 N Y Assumed capacity and age6 Public Works Yard Split Sys Heat Pump Goodman CPE18-1AB 9207013874 1.5 1992 208/230-1-60 N Y Air Handler Info: Goodman, Model # A18-00, SN: 93060820008 Public Works Yard Split Sys Heat Pump Trane TWA090A300FB 82935TYAD 7.5 2008 208/230-3-60 N Y Indoor Unit Info: Trane, Model # TWE090B300EL, SN: 7064M3CBD9 Public Works Yard Wall Mount HP Bard WH361-A05XX4XXX 125J950939212-02 3 1995 208/230-1-60 N Y ID#
Existing Equipment
202
Item5.
Lake Wohlford Ranger Station - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Ranger Station Wall Mount HP Bard WA241-A10XX4XXX 140C001450966-02 2 2000 208/230-1-60 N Y ID#
Existing Equipment
203
Item5.
Real Property - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
3 Escondido Education Compact Packaged Gas / Elec Trane 4YCC3024A106-AA 9361FXU9H 2 2009 208/230-1-60 Down Y Y5 Escondido Education Compact Packaged Gas / Elec Rheem RKKA-A048JK08X 2A6020ADAAF260018910 4 2009 208/230-1-60 Side N Y Replacing with Pkg HP.6 Escondido Education Compact Split Sys Furnace No tag info 3 >15 N Y Replacing with SS Heat Pump.7 Escondido Education Compact Packaged Gas / Elec Trane 2YCC3030A1040AA 8234KPP9H 2.5 2008 208/230-1-60 Side Y Y Replacing with Pkg HP.
ID#
Existing Equipment
204
Item5.
Recycling Office - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Recycling Office Wall Mount HP Bard WH242-A04XX4XXX 140J031827043-02 2 2003 208/230-1-60 N Y2 Recycling Office Wall Mount HP Bard WH242-A10XX4XXX 140N031804355-02 2 2003 208/230-1-60 N Y ID#
Existing Equipment
205
Item5.
Grape Day Park Historical Sites - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
4 Grape Day Park Split Sys Furnace Ameristar 2A7B0048A1000AA 44645WA3F 4 2004 208/230-1-60 N Y Furnace Info: Carrier, Model # NTN6075HFG1, SN: L013368951 ID#
Existing Equipment
206
Item5.
Kit Carson Park - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
2 Sports Center Split Sys Heat Pump Carrier 25HBD3420310 0907E12553 3.5 2007 208/230-1-60 N Y Air Handler Info: Carrier, Model # FC4DNF042000AAAA, SN: 0507A85020 ID#
Existing Equipment
207
Item5.
Dixon Lake Cottage Rental - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Rental Property Split Sys Heat Pump Illegible Illegible Illegible 2 2004 Y ID#
Existing Equipment
208
Item5.
Vineyard Golf Course - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Vinyard Golf Course Split Sys Heat Pump York E1FB009S25A EBCH104110 0.75 1994 208/230-3-60 N Y Indoor: York N4AHD14A06A, SN: EEBS133954 2 Vinyard Golf Course Split Sys Heat Pump York E1FB036S25A ECBM054493 3 1993 208/230-3-60 N Y Indoor: York N3AHD20A06A, SN: EABS003899 ID#
Existing Equipment
209
Item5.
HARFF - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
15 HARFF Split Sys Heat Pump Trane TTA120B400CA Z051LA3AH 10 2001 460-3-60 N Y Indoor: Trane TWE120B300CA, SN: Z042MCM5H 16 HARFF Packaged Gas / Elec Trane TSD150F4R0A03D004D00000000… 140210312D 12.5 2014 460-3-60 Down Y Y Unit has had many issues. Replace w/ Heat Pump20 HARFF Packaged Heat Pump Trane WCD090C400BC R45100895D 7.5 2000 460-3-60 Down Y Y ID#
Existing Equipment
210
Item5.
Water Treatment Plant - HVAC Inventory
Building Equipment Manuf. Model No. Serial No. Capactiy / Size Year Electrical Discharge (Down/Side)
Economizer To be
Replaced?
Additional Notes
1 Water Treatment Plant Packaged Gas / Elec Daikin DCG1202104VXXXAC 1807043386 10 2018 460-3-60 Down Y Y Replacing with Pkg HP. Unit is on Propane.2 Water Treatment Plant Mini Split Mitsubishi PUH18EK 1.5 2008 208/230-1-60 N Y Assumed year to be 2008 based on other Mini-Splits at site.3 Water Treatment Plant Mini Split Mitsubishi PUH24EK 2 2008 208/230-1-60 N Y Assumed year to be 2008 based on other Mini-Splits at site.4 Water Treatment Plant Mini Split Mitsubishi MUH12NN 1 2008 N Y Indoor Unit Info: Mitsubishi, Model #MSH12NN, SN: 8000357T6 Water Treatment Plant Packaged Gas / Elec Daikin DBG0480-----XXAA 1604400045 4 2016 460-3-60 Down Y Y Replacing with Pkg HP. Unit is on Propane.
ID#
211
Item5.
Attachment "E”
Technical Appendix
212
Item5.
SPEC SHEET
1 of 6
Standby Power Rating
130 kW, 163 kVA, 60 Hz
Image used for illustration purposes only
Codes and Standards
Generac products are designed to the following
standards:.
UL2200, UL508, UL489
CSA C22.2
TM
BS5514 and DIN 6271
®
SAE J1349
NFPA 37, 70, 99, 110
NEC700, 701, 702, 708
NEMA ICS10, MG1, 250, ICS6,
AB1
ANSI C62.41
IBC 2009, CBC 2010, IBC 2012,
ASCE 7-05, ASCE 7-10, ICC-ES
AC-156 (2012)
Powering Ahead
Generac provides superior quality by designing and manufacturing most of its generator components, such as alternators, enclosures, control systems and communications software. Generac also makes its own spark-ignited engines, and you’ll find them on every Generac gaseous-fueled generator. We engineer and manufacture them from the block up — all at our facilities throughout Wisconsin. Applying natural gas and LP-fueled engines to generators requires advanced engineering expertise for reliability, durability and necessary performance. By designing specifically for these dry, hotter-burning fuels, the engines last longer and require less maintenance. Building our own engines also means we control every step of the supply chain and delivery process, so you benefit from single-source responsibility.
Plus, Generac Industrial Power’s distribution network provides all parts and service so you don’t have to deal with third-party suppliers. It all leads to a positive owner experience and higher confidence level. Generac spark-ignited engines give you more options in commercial and industrial generator applications as well as extended run time from utility-supplied natural gas.
SG130 | 9.0 L | 130 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
213
Item5.
SPEC SHEET
2 of 6
STANDARD FEATURES
ENGINE SYSTEM
• Oil Drain Extension
• Air Cleaner
• Fan Guard
• Stainless Steel Flexible Exhaust Connection
• Factory Filled Oil and Coolant
• Radiator Duct Adapter (Open Set Only)
• Critical Exhaust Silencer
FUEL SYSTEM
• Fuel Line - NPT Connection
• Primary and Secondary Fuel Shutoff
COOLING SYSTEM
• Closed Coolant Recovery System
• UV/Ozone Resistant Hoses
• Factory-Installed Radiator
• 50/50 Ethylene Glycol Antifreeze
• Radiator Drain Extension
ELECTRICAL SYSTEM
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ALTERNATOR SYSTEM
• GENprotect™
• Class H Insulation Material
• 2/3 Pitch
• Skewed Stator
• Brushless Excitation
• Sealed Bearing
• Amortisseur Winding
• Full Load Capacity Alternator
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Wrapped Exhaust Piping
• Standard Factory Testing
• 2 Year Limited Warranty (Standby Rated Units)
• Silencer Mounted in the Discharge Hood
(Enclosed Only)
ENCLOSURE (If Selected)
• Rust-Proof Fasteners with Nylon Washers to
Protect Finish
• High Performance Sound-Absorbing Material
(Sound Attenuation Enclosures)
• Gasketed Doors
• Stamped Air-Intake Louvers
• Upward Facing Discharge Hoods (Radiator and
Exhaust)
• Stainless Steel Lift Off Door Hinges
• Stainless Steel Lockable Handles
• RhinoCoat™ - Textured Polyester Powder Coat
Paint
CONTROL SYSTEM
Digital H Control Panel- Dual 4x20
Display
Program Functions
• Programmable Crank Limiter
• 7-Day Programmable Exerciser
• Special Applications Programmable Logic
Controller
• RS-232/485 Communications
• 3 Phase Sensing Digital Voltage Regulator
• 2-Wire Start Capability
• Date/Time Fault History (Event Log)
• Isochronous Governor Control
• Waterproof/Sealed Connectors
• Audible Alarms and Shutdowns
• Not in Auto (Flashing Light)
• Auto Off/Manual Switch
• E-Stop (Red Mushroom-Type)
• NFPA110 Level I and II (Programmable)
• Customizable Alarms, Warnings, and Events
• Modbus® Protocol
• Predictive Maintenance Algorithm
• Sealed Boards
• Password Parameter Adjustment Protection
• Single Point Ground
• 16 Channel Remote Trending
• 0.2 msec High Speed Remote Trending
• Alarm Information Automatically Annunciated on
the Display
Full System Status Display
• Power Output (kW)
• Power Factor
• kW Hours, Total, and Last Run
• Real/Reactive/Apparent Power
• All Phase AC Voltage
• All Phase Currents
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Engine Speed
• Battery Voltage
• Frequency
Alarms and Warnings
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Engine Overspeed
• Battery Voltage
• Alarms and Warnings Time and Date Stamped
• Snap Shots of Key Operation Parameters During
Alarms and Warnings
• Alarms and Warnings Spelled Out (No Alarm
Codes)
PARALLELING CONTROLS
• Auto-Synchronization Process
• Isochronous Load Sharing
• Reverse Power Protection
• Maximum Power Protection
• Electrically Operated, Mechanically Held
Paralleling Switch
• Sync Check System
• Independent On-Board Paralleling
• Optional Programmable Logic Full Auto Back-Up
Controls (PLS)
• Shunt Trip and Auxiliary Contact
SG130 | 9.0 L | 130 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
214
Item5.
SPEC SHEET
3 of 6
CONFIGURABLE OPTIONS
ENGINE SYSTEM
○ Engine Block Heater
○ Oil Heater
○ Air Filter Restriction Indicator
○ Stone Guard (Open Set Only)
○ Critical Exhaust Silencer (Open Set Only/Standard
on Ultra Low Emissions Option)
ELECTRICAL SYSTEM
○ 2.5A UL Battery Charger
○ 10A UL Battery Charger
○ Battery Warmer
ALTERNATOR SYSTEM
○ Alternator Upsizing
○ Anti-Condensation Heater
○ Tropical Coating
○ Permanent Magnet Excitation
CIRCUIT BREAKER OPTIONS
○ Main Line Circuit Breaker
○ Electronic Trip Breakers
GENERATOR SET
○ GenLink® Communications Software (English
Only)
○ Extended Factory Testing (3 Phase Only)
○ IBC Seismic Certification
○ 8 Position Load Center
ENCLOSURE
○ Standard Enclosure
○ Level 1 Sound Attenuation
○ Level 2 Sound Attenuation
○ Steel Enclosure
○ Aluminum Enclosure
○ AC/DC Enclosure Lighting Kit
○ Door Alarm Switch
CONTROL SYSTEM
○ Oil Temperature Sender with Indication Alarm
○ Remote E-Stop (Break Glass-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Flush
Mount)
○ Remote Communication - Modem
○ 10A Run Relay
○ Ground Fault Indication and Protection Functions
WARRANTY (Standby Gensets Only)
○ 2 Year Extended Limited Warranty
○ 5 Year Extended Limited Warranty
○ 7 Year Extended Limited Warranty
○ 10 Year Extended Limited Warranty
ENGINEERED OPTIONS
ENGINE SYSTEM
○ Coolant Heater Ball Valves
○ Fluid Containment Pan
CONTROL SYSTEM
○ Battery Disconnect Switch
GENERATOR SET
○ Special Testing
○ Battery Box
ENCLOSURE
○ Motorized Dampers
○ Enclosure Ambient Heaters
○ Up to 200 MPH Wind Load Rating*
SG130 | 9.0 L | 130 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
215
Item5.
SPEC SHEET
4 of 6
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
General
Make Generac
Cylinder # 8
Type V
Displacement - in³ (L) 540 (8.9)
Bore - in (mm) 4.49 (114.3)
Stroke - in (mm) 4.25 (107.95)
Compression Ratio 10.5:1
Intake Air Method Turbocharged/Aftercooled
Number of Main Bearings 5
Connecting Rods Forged
Cylinder Head Cast Iron
Cylinder Liners No
Ignition High Energy
Piston Type Aluminum Alloy
Crankshaft Type Forged Steel
Lifter Type Hydraulic Roller
Intake Valve Material Steel Alloy
Exhaust Valve Material Stainless Steel
Hardened Valve Seats Yes
Engine Governing
Governor Electronic
Frequency Regulation (Steady State) ±0.25%
Lubrication System
Oil Pump Type Gear Driven
Oil Filter Type Full-Flow Spin-On Cartridge
Crankcase Capacity: qt (L) 8.0 (8.5)
Cooling System
Cooling System Type Pressurized Closed
Water Pump Flow - gal/min (l/min) 26
Fan Type Pusher
Fan Speed (RPM) 2,330
Fan Diameter - in (mm) 22 (558)
Fuel System
Fuel Type
Natural Gas, Propane Vapor/
Liquid
Carburetor Down Draft
Secondary Fuel Regulator Standard
Fuel Shut Off Solenoid Standard (Dual)
Operating Fuel Pressure (NG/LPV) 7”-11” H2O
Optional Operating Fuel Pressure (LPL) 30 - 312 psi
*When designing the external fuel system, assume a 20% safety factor to the upper and lower limit of the specified fuel pressure range to account for site variation and measurement at the generator test port. Refer to Generac 10000046207, latest rev, for proper gas supply guidelines (Contact Factory for Details).
Engine Electrical System
System Voltage 12 VDC
Battery Charger Alternator Standard
Battery Size See Battery Index
0161970SBY
Battery Voltage 12 VDC
Ground Polarity Negative
ALTERNATOR SPECIFICATIONS
Standard Model Generac 520
Poles 4
Field Type Revolving
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distortion <5%
Telephone Interference Factor (TIF) <50
Standard Excitation Brushless
Bearings Single Sealed
Coupling Direct via Flexible Disc
Prototype Short Circuit Test Yes
Voltage Regulator Type Full Digital
Number of Sensed Phases 3
Regulation Accuracy (Steady State) ±0.25%
SG130 | 9.0 L | 130 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
216
Item5.
SPEC SHEET
5 of 6
OPERATING DATA
POWER RATINGS
Standby
Single-Phase 120/240 VAC @1.0pf 130 kW/130 kVA Amps: 542 Three-Phase 120/208 VAC @0.8pf 130 kW/163 kVA Amps: 451 Three-Phase 120/240 VAC @0.8pf 130 kW/163 kVA Amps: 391 Three-Phase 277/480 VAC @0.8pf 130 kW/163 kVA Amps: 195 Three-Phase 346/600 VAC @0.8pf 130 kW/163 kVA Amps: 156 STARTING CAPABILITIES (skVA)
skVA vs. Voltage Dip
120/240 VAC 1Ø 30% 277/480 VAC 3Ø 30% 208/240 VAC 3Ø 30% A0130044N21 105 K0130124Y21 327 K0130124Y21 327
A0150044N21 260 K0150124Y21 326 K0150124Y21 244
A0200044N21 459 K0200124Y21 478 K0200124Y21 361
FUEL CONSUMPTION RATES*
Natural Gas – ft³/hr (m³/hr) Propane Vapor – ft³/hr (m³/hr) Propane Liquid – gal/hr Percent Load Standby Percent Load Standby Percent Load Standby 25% 378 (10.7) 25% 204.2 (5.8) 25% 5.70
50% 791.2 (22.4) 50% 341.8 (9.7) 50% 9.54
75% 1,144.5 (32.4) 75% 470.0 (13.3) 75% 13.12
100% 1,496.0 (42.4) 100% 593.7 (16.8) 100% 16.57
*1.5X maximum site rated fuel consumption should be used for gas supply design practices. Refer to Generac 10000046207, latest rev., for more information or contact factory for details.
COOLING
Standby
Air Flow (inlet air combustion and radiator) ft³/min (m³/min) 5,757 (163.0) Coolant Flow per Minute gal/min (L/min) 26 (98)
Coolant System Capacity gal (L) 6.0 (22.7)
Heat Rejection to Coolant BTU/hr 302,400
Maximum Radiator Backpressure in H2O (kPa) 0.5 (0.12)
COMBUSTION AIR REQUIREMENTS
Standby
Flow at Rated Power cfm — (m³/min) 349 (9.9)
ENGINE
Standby
Rated Engine Speed RPM 1,800
Horsepower at Rated kW** hp 200
Piston Speed ft/min 1,275
BMEP psi 162
** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
EXHAUST
Standby
Exhaust Flow (Rated Output) cfm (m³/min) 1,341 (38.0)
Maximum Exhaust Backpressure inHG (kPa) 0.75 (2.54)
Exhaust Temp (Rated Output - Post
Silencer)
°F (°C) 1,112 (600)
Exhaust Size Outlet in (mm) 3.0" ID Flex (No Silencer)
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with BS5514 and DIN6271 standards.
Standby - See Bulletin 0187500SSBCom
Prime - See Bulletin 0187510SSB
SG130 | 9.0 L | 130 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
217
Item5.
SPEC SHEET
Generac Power Systems, Inc. | S45 W29290 HWY. 59 | Waukesha, WI 53189 | generac.com ©2025 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Part No. 0K6449
Rev. F 03/04/2025
6 of 6
SG130 | 9.0 L | 130 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
DIMENSIONS AND WEIGHTS*
L
L
L
L
W
W
W
W
H
H
H
H
OPEN SET (Includes Exhaust Flex)
L x W x H - in (mm) 110 (2,795) x 39.4 (1,000.2) x 54.3 (1,378) Weight - lbs 2,674 (1,213)
STANDARD ENCLOSURE
L x W x H - in (mm) 132.72 (3,371.1) x 40.46 (1,027.8) x 64.05 (1,627) Weight - lbs Steel: 3,434 (1,558)
Aluminum: 3,055 (1,386)
LEVEL 1 ACOUSTIC ENCLOSURE
L x W x H - in (mm) 154.13 (3,914.9) x 40.46 (1,027.8) x 64.05 (1,627) Weight - lbs Steel: 3,670 (1,665)
Aluminum: 3,157 (1,432)
LEVEL 2 ACOUSTIC ENCLOSURE
L x W x H - in (mm) 144.53 (3,671) x 40.46 (1,027.8) x 80.88 (2,054.3) Weight - lbs Steel: 3,789 (1,719)
Aluminum: 3,207 (1,455)
*All measurements are approximate and for estimation purposes only.
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. 218
Item5.
1 OF 6SPEC SHEET
SG130 | 9.0L | 130kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
*Assembled in the USA using
domestic and foreign parts
Image used for illustration purposes only
POWERING AHEAD
Generac ensures superior quality by designing and manufacturing most of its generator components, such as alternators, enclosures, control systems and communications software. But Generac also makes its own spark-ignited engines, and you’ll find them on every Generac gaseous-fueled generator. We engineer and manufacture them from the block up - all at our facilities throughout Wisconsin.
Because applying natural gas and LP-fueled engines to generators requires advanced engineering expertise to ensure reliability, durability and necessary performance. By designing specifically for these dry, hotter-burning fuels, the engines last longer and require less maintenance. Building our own engines also means we control every step of the supply chain and delivery process, so you benefit from single-source responsibility.
Plus, Generac Industrial Power’s distribution network provides all parts and service so you don’t have to deal with third-party suppliers. It all leads to a positive owner experience and higher confidence level. Generac spark-ignited engines give you more options in commercial and industrial generator applications as well as extended run time from utility-supplied natural gas.
Standby Power Rating
130 kW, 163 kVA, 60 Hz
CODES AND STANDARDS
Not all codes and standards apply to all configurations. Contact factory for details.
UL2200, UL508, UL489
CSA C22.2, B149
TM
BS5514 and DIN 6271
®
SAE J1349
NFPA 37, 70, 99, 110
®
NEC 700, 701, 702, 708
ISO 3046, 8528, 9001
NEMA ICS1, ICS10, MG1, 250, ICS6,
AB1
ANSI/IEEE C62.41
IBC 2009, CBC 2010, IBC 2012,
ASCE 7-05, ASCE 7-10,
ICC-ES AC-156 (2012)
*EPA Certified Prime ratings are not available in the US or its Territories 219
Item5.
2 OF 6SPEC SHEET
SG130 | 9.0L | 130kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
ENGINE SYSTEM
• Oil Drain Extension
• Air Cleaner
• Fan Guard
• Stainless Steel Flexible Exhaust Connection
• Factory Filled Oil & Coolant
• Radiator Duct Adapter (Open Set Only)
• Critical Exhaust Silencer/Catalyst
Fuel System
• NPT Fuel Connection on Frame
• Primary and Secondary Fuel Shutoff
Cooling System
• Closed Coolant Recovery System
• Factory-Installed Radiator
• 50/50 Ethylene Glycol Antifreeze
• Radiator Drain Extension
• UV/Ozone Resistant Hoses
Electrical System
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ALTERNATOR SYSTEM
• UL220 GENprotect™ Fault Protector
• Class H Insulation Material
• 2/3 Pitch
• Skewed Stator
• Brushless Excitation
• Sealed Bearings
• Amortisseur Winding
• /RZ7HPSHUDWXUH5LVH&
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Wrapped Exhaust Piping (Enclosed Units Only)
• Standard Factory Testing
• 2 Year Limited Warranty (Standby Rated Units)
• Capable to Accept Full Load in <10 Seconds
• Silencer Mounted in the Discharge Hood (Enclosed
Units Only)
ENCLOSURE (If Selected)
• Rust-Proof Fasteners with Nylon Washers to
Protect Finish
• High Performance Sound-Absorbing Material (Sound
Attenuation Enclosures)
• Gasketed Doors
• Stamped Air-Intake Louvers
• Upward Facing Discharge Hoods (Radiator
and Exhaust)
• Stainless Steel Lockable Handles
• RhinoCoat™ - Textured Polyester Powder Coat Paint
CONTROL SYSTEM
Digital H Control Panel- Dual 4x20 Display
Program Functions
• Programmable Crank Limiter
• 7-Day Programmable Exerciser
• Special Applications Programmable Logic Controller
• RS-232/485 Communications
• All-Phase Sensing Digital Voltage Regulator
• Utility Monitoring
• 2-Wire Start Capability
• Date/Time Fault History (Event Log)
• Isochronous Governor Control
• Waterproof/Sealed Connectors
• Audible Alarms and Shutdowns
• Not in Auto (Flashing Light)
• Auto/Off/Manual Switch
• E-Stop (Red Mushroom-Type)
• NFPA110 Level I and II (Programmable)
• Customizable Alarms, Warnings, and Events
• Modbus® Protocol
• Predictive Maintenance Algorithm
• Sealed Boards
• Password Parameter Adjustment Protection
• Single Point Ground
• 16 Channel Remote Trending
• 0.2msec High Speed Remote Trending
• Alarm Information Automatically Annunciated
on the Display
Full System Status Display
• Power Output (kW)
• Power Factor
• kW Hours, Total & Last Run
• Real/Reactive/Apparent Power
• All Phase AC Voltage
• All Phase Currents
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Engine Speed
• Battery Voltage
• Frequency
Alarms and Warnings
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Low Fuel Pressure
• Engine Overspeed
• Battery Voltage
• Alarms & Warnings Time and Date Stamped
• Snap Shots of Key Operation Parameters During
• Alarms & Warnings
• Alarms and Warnings Spelled Out (No Alarm Codes)
STANDARD FEATURES
220
Item5.
3 OF 6SPEC SHEET
SG130 | 9.0L | 130kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
ENGINE SYSTEM
ż Engine Block Heater
ż Extreme Cold Weather Kit
ż Oil Heater
ż Air Filter Restriction Indicator
ż Radiator Stone Guard (Open Set Only)
ELECTRICAL SYSTEM
ż 10A UL Battery Charger
ż Battery Warmer
FUEL SYSTEM
ż NPT Flexible Fuel Line
ALTERNATOR SYSTEM
ż Alternator Upsizing
ż Anti-Condensation Heater
ż Topical Alternator Coating
GENERATOR SET
ż GenLink Communications Software (English Only)
ż Extended Factory Testing (3-Phase Only)
ż 8 Position Load Center
ż Seismic Certification
MAIN LINE CIRCUIT BREAKER OPTIONS
ż 2nd Main Line Circuit Breaker
ż Shunt Trip and Auxiliary Contact
ż Electronic Trip Breakers
CONTROL SYSTEM
ż NFPA 110 Level 1 Compliant 21-Light Remote
Annunciator
ż Remote Output Relays (8 or 16)
ż Oil Temperature Indication and Alarm
ż Remote E-Stop (Break Glass-Type, Surface Mount)
ż Remote E-Stop (Red Mushroom-Type,
Surface Mount)
ż Remote E-Stop (Red Mushroom-Type, Flush Mount)
ż 10A Engine Run Relay
ż Ground Fault Annunciator
ż Damper Alarm Contacts
ż 100dB Alarm Horn
ż 120V GFCI and 240V Outlets
ż Auxiliary Circuit Breaker Contacts to Controller
ENCLOSURE
ż Weather Protected Enclosure
ż Level 1 Sound Attenuation
ż Level 2 Sound Attenuation
ż Level 2 Sound Attenuation with Motorized Dampers
ż Steel Enclosure
ż Aluminum Enclosure
ż AC/DC Enclosure Lighting Kit
ż Door Alarm Switch
ż Enclosure Ambient Heaters
ż Up to 200 MPH Wind Load Rating (Consult Factory
for Availability)
WARRANTY (Standby Gensets Only)
ż 2 Year Extended Limited Warranty
ż 5 Year Limited Warranty
ż 5 Year Extended Limited Warranty
ż 7 Year Extended Limited Warranty
ż 10 Year Extended Limited Warranty
CONFIGURABLE OPTIONS
CONTROL SYSTEM
ż Battery Disconnect Switch
ALTERNATOR SYSTEM
ż 3rd Main Line Circuit Breaker
ż Unit Mounted Load Banks
GENERATOR SET
ż Special Testing
ż Battery Box
ENGINEERED OPTIONS
221
Item5.
4 OF 6SPEC SHEET
SG130 | 9.0L | 130kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
General
Make Generac
Cylinder # 8
Type V
Displacement - in3
(L) 540 (8.9)
Bore - in (mm) 4.49 (114.23)
Stroke - in (mm) 4.25 (107.15)
Compression Ratio 10.5:1 - G18 9.1:1 - G26
Intake Air Method Turbocharged/Aftercooled
Number of Main Bearings 5
Cylinder Head Forged Steel
Ignition High Energy
Piston Type Aluminum Alloy
Crankshaft Type Forged Steel
Lifter Type Hydraulic Roller
Intake Valve Material Steel Alloy
Exhaust Valve Material Stainless Steel
Hardened Valve Seats Yes
Engine Governing
Governor Electronic
Frequency Regulation (Steady State) ±0.25%
Lubrication System
Oil Pump Type Gear
Oil Filter Type Full-Flow Spin-On Cartridge
Crankcase Capacity with Filters - L (qts) 8.5 (8.0) - G18 9.5 (10.0) - G26 Cooling System
Cooling System Type Pressurized Closed
Fan Type Pusher
Fan Speed (rpm) 2,330
Fan Diameter - in (mm) 22 (558)
Fuel System
Fuel Type Natural Gas
Carburetor Down Draft
Secondary Fuel Regulator Standard
Fuel Shut Off Solenoid Standard
Operating Fuel Pressure NG/LPV- H2
O
(kPa)
7-11 (1.7- 2.7)
Operating Fuel Pressure LPL- psi (kPa) 30 - 312 (206 - 2,151) Engine Electrical System
System Voltage 12 VDC
Battery Charger Alternator Standard
Battery Size See Battery Index 0161970SBY
Battery Voltage 12 VDC
Ground Polarity Negative
NOTE: G18 is all engines manufactured before August 3rd, 2018 . G26 is all engines manufactured after August 3rd, 2018.
ALTERNATOR SPECIFICATIONS
Standard Model K0130124Y21
Poles 4
Field Type Rotating
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distortion <5% (3-Phase Only)
Telephone Interference Factor (TIF) <50
Standard Excitation Brushless Excitation
Bearings Single Sealed
Coupling Direct via Flexible Disc
Prototype Short Circuit Test Yes
Voltage Regulator Type Full Digital
Regulation Accuracy (Steady State) ±0.25%
222
Item5.
5 OF 6SPEC SHEET
SG130 | 9.0L | 130kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
OPERATING DATA
POWER RATINGS- NATURAL GAS/PROPANE/DUAL FUEL
MOTOR STARTING CAPABILITIES (skVA)
FUEL CONSUMPTION RATES
COOLING
COMBUSTION AIR REQUIREMENTS
ENGINE EXHAUST
Standby
Single-Phase 120/240VAC @1.0pf 130 kW Amps: 542
Three-Phase 120/208 VAC @0.8pf 130 kW Amps: 451
Three-Phase 120/240 VAC @0.8pf 130 kW Amps: 391
Three-Phase 277/480 VAC @0.8pf 130 kW Amps: 196
Three-Phase 346/600 VAC @0.8pf 130 kW Amps: 156
skVA vs. Voltage Dip
277/480 VAC 30% 208/480 VAC 30%
K0130124Y21 327 K0130124Y21 327
K0150124Y21 326 K0150124Y21 244
K0200124Y21 478 K0200124Y21 361
Natural Gas – cfh (m3/hr) Propane Vapor - cfh (m3/hr) Propane Liquid- gal/hr (l/hr) Percent Load Standby Percent Load Standby Percent Load Standby 25% 635 (18.0) 25% 270 (7.6) 25% 6.5 (24.6)
50% 1,005 (28.4) 50% 390 (11.0) 50% 10.1 (38.2)
75% 1,401 (39.7) 75% 516 (14.6) 75% 14.0 (52.9)
100% 1,797 (50.9) 100% 642 (18.2) 100% 17.7 (67.0)
* Fuel supply installation must accommodate fuel consumption rates at 100% load.
Standby
Air Flow (Fan Air Flow Across Radiator) scfm (m3
/min) 5,415 (153.3)
Coolant Flow gpm (Lpm) 27.5 (104)
Coolant System Capacity Gal (L) 6.34 (24.0)
Max. Operating Ambient Temperature )
&
122 (50)
Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD Maximum Radiator Backpressure in H2
O (kPa) 0.50 (0.12)
Standby
Flow at Rated Power scfm (m3
/min) 370.9 (10.5)
Standby Standby
Rated Engine Speed rpm 1,800 Exhaust Flow (Rated Output) scfm (m3 /min) 1,198 (34)
Horsepower at Rated kW** hp 200- G18 205- G26 Max. Backpressure (Post Silencer) inHg (kPa) 0.75 (2.54) Piston Speed ft/min (m/min) 1,275 (389) Exhaust Temp (Rated Output - Post Silencer) ) &
1,285 (696)
BMEP psi (kPa) 166 (1145)
** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please consult a Generac Power Systems Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards.
Standby - See Bulletin - 1000001893
223
Item5.
6 OF 6SPEC SHEET
SG130 | 9.0L | 130kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
DIMENSIONS AND WEIGHTS*†
* All measurements are approximate and for estimation purposes only. † Dimensions based on unit with the Standard Model Alternator Specification characteristics may change without notice. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings.
Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53189 P: (262) 544-4811 ©2018 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Part No 0K6449
Rev. I 06/25/18
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
L
L
L
LW
W
W
W
H
H
H
H
WEATHER PROTECTED ENCLOSURE
L x W x H - in (mm) 132.7 (3,371) x 40.5 (1,028) x 63.1 (1,604) Weight - lbs (kg) Steel: 3,435 (1,558)
Aluminum: 3,056 (1,386)
LEVEL 1 ACOUSTIC ENCLOSURE
L x W x H - in (mm) 154.1 (3,915) x 40.5 (1,028) x 63.1 (1,604) Weight - lbs (kg) Steel: 3,671 (1,665)
Aluminum: 3,157 (1,432)
LEVEL 2 ACOUSTIC ENCLOSURE
L x W x H - in (mm) 144.5 (3,670) x 40.5 (1,028) x 80.0 (2,031) Weight - lbs (kg) Steel: 3,790 (1,719)
Aluminum: 3,208 (1,455)
OPEN SET (Includes Exhaust Flex)
L x W x H - in (mm) 110.0 (2,795) x 39.9 (1,013) x 54.3 (1,379) Weight - lbs (kg) 2,674 (1,213)
224
Item5.
SPEC SHEET
1 of 6
Standby Power Rating
150 kW, 188 kVA, 60 Hz
Image used for illustration purposes only
Codes and Standards
Generac products are designed to the following
standards:.
UL2200, UL508, UL489
CSA C22.2
TM
BS5514 and DIN 6271
®
SAE J1349
NFPA 37, 70, 99, 110
NEC700, 701, 702, 708
NEMA ICS10, MG1, 250, ICS6,
AB1
ANSI C62.41
IBC 2009, CBC 2010, IBC 2012,
ASCE 7-05, ASCE 7-10, ICC-ES
AC-156 (2012)
Powering Ahead
Generac provides superior quality by designing and manufacturing most of its generator components, such as alternators, enclosures, control systems and communications software. Generac also makes its own spark-ignited engines, and you’ll find them on every Generac gaseous-fueled generator. We engineer and manufacture them from the block up — all at our facilities throughout Wisconsin. Applying natural gas and LP-fueled engines to generators requires advanced engineering expertise for reliability, durability and necessary performance. By designing specifically for these dry, hotter-burning fuels, the engines last longer and require less maintenance. Building our own engines also means we control every step of the supply chain and delivery process, so you benefit from single-source responsibility.
Plus, Generac Industrial Power’s distribution network provides all parts and service so you don’t have to deal with third-party suppliers. It all leads to a positive owner experience and higher confidence level. Generac spark-ignited engines give you more options in commercial and industrial generator applications as well as extended run time from utility-supplied natural gas.
SG150 | 9.0 L | 150 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
225
Item5.
SPEC SHEET
2 of 6
STANDARD FEATURES
ENGINE SYSTEM
• Oil Drain Extension
• Air Cleaner
• Fan Guard
• Stainless Steel Flexible Exhaust Connection
• Factory Filled Oil and Coolant
• Radiator Duct Adapter (Open Set Only)
• Critical Silencer/Catalyst
FUEL SYSTEM
• NPT Fuel Connection on Frame
• Primary and Secondary Fuel Shutoff
COOLING SYSTEM
• Closed Coolant Recovery System
• UV/Ozone Resistant Hoses
• Factory-Installed Radiator
• 50/50 Ethylene Glycol Antifreeze
• Radiator Drain Extension
ELECTRICAL SYSTEM
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ALTERNATOR SYSTEM
• UL2200 GENprotect™
• Class H Insulation Material
• 2/3 Pitch
• Skewed Stator
• Permanent Magnet Excitation
• Sealed Bearings
• Amortisseur Winding
• Full Load Capacity Alternator
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Wrapped Exhaust Piping
• Standard Factory Testing
• 2 Year Limited Warranty (Standby Rated Units)
• Silencer Mounted in the Discharge Hood
(Enclosed Only)
ENCLOSURE (If Selected)
• Rust-Proof Fasteners with Nylon Washers to
Protect Finish
• High Performance Sound-Absorbing Material
(Sound Attenuation Enclosures)
• Gasketed Doors
• Stamped Air-Intake Louvers
• Upward Facing Discharge Hoods (Radiator and
Exhaust)
• Stainless Steel Lift Off Door Hinges
• Stainless Steel Lockable Handles
• RhinoCoat™ - Textured Polyester Powder Coat
Paint
CONTROL SYSTEM
Digital H Control Panel- Dual 4x20
Display
Program Functions
• Programmable Crank Limiter
• 7-Day Programmable Exerciser
• Special Applications Programmable Logic
Controller
• RS-232/485 Communications
• 3 Phase Sensing Digital Voltage Regulator
• 2-Wire Start Capability
• Date/Time Fault History (Event Log)
• Isochronous Governor Control
• Waterproof/Sealed Connectors
• Audible Alarms and Shutdowns
• Not in Auto (Flashing Light)
• Auto Off/Manual Switch
• E-Stop (Red Mushroom-Type)
• NFPA110 Level I and II (Programmable)
• Customizable Alarms, Warnings, and Events
• Modbus® Protocol
• Predictive Maintenance Algorithm
• Sealed Boards
• Password Parameter Adjustment Protection
• Single Point Ground
• 16 Channel Remote Trending
• 0.2 msec High Speed Remote Trending
• Alarm Information Automatically Annunciated on
the Display
Full System Status Display
• Power Output (kW)
• Power Factor
• kW Hours, Total, and Last Run
• Real/Reactive/Apparent Power
• All Phase AC Voltage
• All Phase Currents
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Engine Speed
• Battery Voltage
• Frequency
Alarms and Warnings
• Oil Pressure
• Coolant Temperature
• Coolant Level
• Engine Overspeed
• Battery Voltage
• Alarms and Warnings Time and Date Stamped
• Snap Shots of Key Operation Parameters During
Alarms and Warnings
• Alarms and Warnings Spelled Out (No Alarm
Codes)
PARALLELING CONTROLS
• Auto-Synchronization Process
• Isochronous Load Sharing
• Reverse Power Protection
• Maximum Power Protection
• Electrically Operated, Mechanically Held
Paralleling Switch
• Sync Check System
• Independent On-Board Paralleling
• Optional Programmable Logic Full Auto Back-Up
Controls (PLS)
• Shunt Trip and Auxiliary Contact
SG150 | 9.0 L | 150 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
226
Item5.
SPEC SHEET
3 of 6
CONFIGURABLE OPTIONS
ENGINE SYSTEM
○ Engine Block Heater
○ Oil Heater
○ Air Filter Restriction Indicator
○ Radiator Stone Guard (Open Set Only)
○ Baseframe Cover/Rodent Guard
○ Level 1 Fan and Belt Guards (Enclosed Units Only)
○ Shipped Loose Critical Silencer (Open Set Only)
FUEL SYSTEM
○ NPT Flexible Fuel Line
○ Dual Fuel NG/LPV
○ Dual Fuel NG/LPL
ELECTRICAL SYSTEM
○ 10A UL Battery Charger
○ Battery Warmer
ALTERNATOR SYSTEM
○ Alternator Upsizing
○ Anti-Condensation Heater
○ Tropical Coating
CIRCUIT BREAKER OPTIONS
○ Main Line Circuit Breaker
○ 2nd main Line Circuit Breaker
○ Shunt Trip and Auxiliary Contact
○ Electronic Trip Breakers
GENERATOR SET
○ Demand Response Rating
○ Extended Factory Testing (3 Phase Only)
○ IBC Seismic Certification
○ 8 Position Load Center
ENCLOSURE
○ Weather Protected Enclosure
○ Level 1 Sound Attenuated
○ Level 2 Sound Attenuated
○ Level 2 Sound Attenuated with Motorized
Dampers
○ Steel Enclosure
○ Aluminum Enclosure
○ AC/DC Enclosure Lighting Kit
○ Enclosure Heater
○ Pad Vibration Isolation
○ Up to 200 MPH Wind Load Rating (Contact
Factory for Availability)
○ Door Open Alarm Switch
CONTROL SYSTEM
○ NFPA 110 Compliant Level 1 21-Light Remote
Annunciator
○ Remote Relay Assembly (8 or 16)
○ Oil Temperature Indication and Alarm
○ Remote E-Stop (Break Glass-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Flush
Mount)
○ 10A Engine Run Relay
○ Ground Fault Annunciator
○ 100 dB Alarm Horn
○ 120V GFCI and 240V Outlets
○ Damper Alarm Contacts (Motorized Dampers
Only)
○ Auxiliary Circuit Breaker Contacts to Controller
WARRANTY (Standby Gensets Only)
○ 2 Year Extended Limited Warranty
○ 5 Year Extended Limited Warranty
○ 7 Year Extended Limited Warranty
○ 10 Year Extended Limited Warranty
ENGINEERED OPTIONS
ENGINE SYSTEM
○ Coolant Heater Ball Valves
○ Fluid Containment Pan
ATLERNATOR SYSTEM
○ 3rd Breaker System
CONTROL SYSTEM
○ Battery Disconnect Switch
GENERATOR SET
○ Special Testing
○ Battery Box
SG150 | 9.0 L | 150 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
227
Item5.
SPEC SHEET
4 of 6
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
General
Make Generac
Cylinder # 8
Type V
Displacement - in³ (L) 543 (8.9)
Bore - in (mm) 4.49 (114.3)
Stroke - in (mm) 4.25 (108)
Compression Ratio G18 - 10.5:1 / G26 - 9.1:1 *
Intake Air Method Turbocharged/Aftercooled
Number of Main Bearings 5
Connecting Rods Forged Steel
Cylinder Head Cast Iron
Cylinder Liners No
Ignition High Energy
Piston Type Aluminum Alloy
Crankshaft Type Forged Steel
Lifter Type Hydraulic Roller
Intake Valve Material Steel Alloy
Exhaust Valve Material Stainless Steel
Hardened Valve Seats Yes
Engine Governing
Governor Electronic
Frequency Regulation (Steady State) ±0.25%
Lubrication System
Oil Pump Type Gear Driven
Oil Filter Type Full-Flow Spin-On Cartridge
Crankcase Capacity: qt (L) G18 - 8.5 (8.0) / G26 - 9.5 (10.0) *
Cooling System
Cooling System Type Pressurized Closed
Fan Type Pusher
Fan Speed (RPM) G18 - 2,330 / G26 - 2,386 *
Fan Diameter - in (mm) 22 (559)
Fuel System
Fuel Type
Natural Gas, Propane Vapor/
Liquid
Carburetor Down Draft
Secondary Fuel Regulator Standard
Fuel Shut Off Solenoid Standard
Operating Fuel Pressure - in H2O 7 - 11 (1.7 - 2.7)
Optional Operating Fuel Pressure (LPL) — psi (KPa) 30 - 312 (206 - 2,151) *When designing the external fuel system, assume a 20% safety factor to the upper and lower limit of the specified fuel pressure range to account for site variation and measurement at the generator test port. Refer to Generac 10000046207, latest rev, for proper gas supply guidelines (Contact Factory for Details).
Engine Electrical System
System Voltage 12 VDC
Battery Charger Alternator Standard
Battery Size See Battery Index
0161970SBY
Battery Voltage 12 VDC
Ground Polarity Negative
* G18 refers to all engines manufactured before August 3rd, 2018. G26 refers to all engines manufactured after August 3rd, 2018.
ALTERNATOR SPECIFICATIONS
Standard Model K0150124Y26
Poles 4
Field Type Revolving
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distortion <5%
Telephone Interference Factor (TIF) <50
Standard Excitation Permanent Magnet
Bearings Single Sealed Ball
Coupling Direct Drive
Prototype Short Circuit Test Yes
Voltage Regulator Type Full Digital
Number of Sensed Phases All
Regulation Accuracy (Steady State) ±0.25%
SG150 | 9.0 L | 150 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
228
Item5.
SPEC SHEET
5 of 6
OPERATING DATA
POWER RATINGS
G18, G26 - Natural Gas * G18, G26 - Propane/Dual Fuel * Single-Phase 120/240 VAC @ 1.0pf 144 kW/144 kVA Amps: 600 134 kW/134 KVA Amps: 558 Three-Phase 120/208 VAC @0.8pf 150 kW/188 kVA Amps: 521 140 kW/175 kVA Amps: 486 Three-Phase 120/240 VAC @0.8pf 150 kW/188 kVA Amps: 452 140 kW/175 kVA Amps: 422 Three-Phase 277/480 VAC @0.8pf 150 kW/188 kVA Amps: 226 140 kW/175 kVA Amps: 211 Three-Phase 346/600 VAC @0.8pf 150 kW/188 kVA Amps: 181 140 kW/175 kVA Amps: 169 MOTOR STARTING CAPABILITIES (skVA)
skVA vs. Voltage Dip
277/480 VAC 30% 208/240 VAC 30%
K0150124Y26 327 K0150124Y26 250
K0200124Y21 478 K0200124Y21 361
FUEL CONSUMPTION RATES*
Natural Gas – scfh (m³/hr) Propane Vapor – scfh (m³/hr) Propane Liquid – gal/hr (Lph) Percent Load Standby Percent Load Standby Percent Load Standby 25% 668 (18.9) 25% 280 (7.9) 25% 6.7 (25.4)
50% 1,127 (31.9) 50% 430 (12.2) 50% 11.4 (43.2)
75% 1,583 (44.8) 75% 573 (16.2) 75% 15.7 (59.4)
100% 2,042 (57.8) 100% 720 (20.4) 100% 20.0 (75.7)
*1.5X maximum site rated fuel consumption should be used for gas supply design practices. Refer to Generac 10000046207, latest rev., for more information or contact factory for details.
COOLING
Standby
Air Flow (Fan Air Flow Across Radiator) cfm (m³/min) 5,598 (158.5) Coolant Flow gpm (Lpm) 27.5 (104)
Coolant System Capacity gal (L) 6.3 (24.0)
Maximum Operating Air Temperature on Radiator °F (°C) 122 (50) Maximum Operating Ambient Temperature (Before Derate) See Bulletin 0199270SSD Maximum Radiator Backpressure in H2O (kPa) 0.5 (0.12)
COMBUSTION AIR REQUIREMENTS
Standby
Flow at Rated Power cfm — (m³/min) 343 (9.7)
ENGINE
Standby
Rated Engine Speed RPM 1,800
Horsepower at Rated kW** hp 229
Piston Speed ft/min (m/min) 1,275 (389)
BMEP psi (kPa) 185 (1,277)
** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
EXHAUST
Standby
Exhaust Flow (Rated Output) cfm (m³/min) 1,206 (34.1)
Maximum Exhaust Backpressure inHG (kPa) 0.75 (2.54)
Exhaust Temp (Rated Output - Post
Silencer) °F (°C) 1,440 (782)
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with BS5514 and DIN6271 standards.
Standby - See Bulletin 0187500SSB
SG150 | 9.0 L | 150 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
229
Item5.
SPEC SHEET
Generac Power Systems, Inc. | S45 W29290 HWY. 59 | Waukesha, WI 53189 | generac.com ©2025 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Part No. 0K6450
Rev. M 04/01/2025
6 of 6
SG150 | 9.0 L | 150 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency
DIMENSIONS AND WEIGHTS*
L
L
L
L
W
W
W
W
H
H
H
H
OPEN SET (Includes Exhaust Flex)
L x W x H - in (mm) 116.5 (2,959) x 49.7 (1,262) x 55.6 (1,412) Weight - lbs 2,946 (1,336)
WEATHER PROTECTED ENCLOSURE
L x W x H - in (mm) 143.0 (3,631) x 50.4 (1,280) x 68.2 (1,732 Weight - lbs Steel: 3,843 (1,743)
Aluminum: 3,384 (1,535)
LEVEL 1 ACOUSTIC ENCLOSURE
L x W x H - in (mm) 143.0 (3,632) x 50.4 (1,280) x 91.7 (2,329) Weight - lbs Steel: 4,321 (1,960)
Aluminum: 3,592 (1,629)
LEVEL 2 ACOUSTIC ENCLOSURE
L x W x H - in (mm) 144.53 (3,671) x 40.46 (1,027.8) x 80.88 (2,054.3) Weight - lbs Steel: 3,789 (1,719)
Aluminum: 3,207 (1,455)
*All measurements are approximate and for estimation purposes only.
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings. 230
Item5.
SPEC SHEET
1 of 6
Standby Power Rating
200 kW, 250 kVA, 60 Hz
Demand Response Rating
200 kW, 250 kVA, 60 Hz
Prime Power Rating
180 kW, 225 kVA, 60 Hz
**
** Offered on units sold in the U.S. and Canada
Image used for illustration purposes only
Codes and Standards
Not all codes and standards apply to all
configurations. Contact factory for details.
UL2200, UL6200, UL1236, UL489
CSA C22.2, B149
TM
BS5514 and DIN 6271
®
SAE J1349
NFPA 37, 70, 99, 110
NEC700, 701, 702, 708
NEMA ICS10, MG1, 250, ICS6,
AB1
ANSI C62.41
IBC 2009, CBC 2010, IBC 2012,
ASCE 7-05, ASCE 7-10, ICC-ES
AC-156 (2012)
Powering Ahead
Generac provides superior quality by designing and
manufacturing most of its generator components, such
as alternators, enclosures, control systems and communications software. Generac also makes its own spark-ignited engines, and they can be found on every
Generac gaseous-fueled generator. We engineer and
manufacture them from the block up — all at our facilities throughout Wisconsin. Applying natural gas and LPfueled engines to generators requires advanced engineering expertise for reliability, durability and necessary performance. By designing specifically for these dry,
hotter-burning fuels, the engines last longer and require less maintenance. Building our own engines also means
we control every step of the supply chain and delivery
process, so you benefit from single-source
responsibility.
Plus, Generac Industrial Power’s distribution network
provides all parts and service so owners don’t have to
deal with third-party suppliers. It all leads to a positive owner experience and higher confidence level. Generac
spark-ignited engines give more options in commercial
and industrial generator applications as well as extended run time from utility-supplied natural gas.
SG200 | 14.2L | 200 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
231
Item5.
SPEC SHEET
2 of 6
STANDARD FEATURES
ENGINE SYSTEM
• Oil Drain Extension
• Air Cleaner
• Fan Guard (Open Sets Only)
• Stainless Steel Flexible Exhaust Connection
• Factory Filled Oil and Coolant
• Radiator Duct Adapter (Open Set Only)
• Critical Silencer (Enclosed Units Only)
• Oil Temperature Indication and Alarm
FUEL SYSTEM
• NPT Fuel Connection on Frame
• Primary and Secondary Fuel Shutoff
COOLING SYSTEM
• Closed Coolant Recovery System
• UV/Ozone Resistant Hoses
• Factory-Installed Radiator
• 50/50 Ethylene Glycol Antifreeze
• Radiator Drain Extension
ELECTRICAL SYSTEM
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ENCLOSURE (If Selected)
• Rust-Proof Fasteners with Nylon Washers to
Protect Finish
• High Performance Sound-Absorbing Material
(Sound Attenuated Enclosures)
• Gasketed Doors
• Upward Facing Discharge Hood (Radiator and
Exhaust)
• Stainless Steel Lift Off Door Hinges
• Stainless Steel Lockable Handles
• RhinoCoat™ - Textured Polyester Powder Coat
Paint
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Wrapped Exhaust Piping
• Standard Factory Testing
• 2 Year Limited Warranty (Standby and Demand
Response Rated Units)
• 1 Year Limited Warranty (Prime Rated Units)
• Silencer Mounted in the Discharge Hood
(Enclosed Units Only)
• Ready to Accept Full Load in <10 Seconds
ALTERNATOR SYSTEM
• UL2200 GENprotect™
• Main Line Circuit Breaker
• Class H Insulation Material
• 2/3 Pitch
• Skewed Stator
• Permanent Magnet Excitation
• Sealed Bearing
• Amortisseur Winding
• Full Load Capacity Alternator
CONTROL SYSTEM
Power Zone® Pro Sync Controller
Program Functions
• NFPA 110 Level 1 Compliant
• Engine Protective Functions
• Alternator Protective Functions
• Digital Engine Governor Control
• Digital Voltage Regulator
• Multiple Programmable Inputs and Outputs
• Remote Display Capability
• Remote Communication via Modbus® RTU,
Modbus TCP/IP, and Ethernet 10/100
• Alarm and Event Logging with Real Time
Stamping
• Expandable Analog and Digital Inputs and Outputs
• Remote Wireless Software Update Capable
• BMS and Remote Telemetry
• Built-In Programmable Logic Eliminates the Need
for External Controllers Under Most Conditions
• Ethernet Based Communications Between
Generators
• Programmable I/O Channel Properties
• Built-In Diagnostics
• Arc Flash Maintenance Mode (When Correctly
Equipped)
Alarms and Warnings
• Low Oil Pressure
• Low Coolant Level
• High/Low Coolant Temperature
• Sensor Failure
• Oil Temperature
• Over/Under Speed
• Over/Under Voltage
• Over/Under Frequency
• Over/Under Current
• Over Load
• High/Low Battery Voltage
• Battery Charger Current
• Phase to Phase and Phase to Neutral Short
Circuits (I2T Algorithm)
7 Inch Color Touch Screen Display
• Resistive Color Touch Screen
• Sunlight Readable (1400 NITS)
• Easily Identifiable Icons
• Multi-Lingual
• On Screen Editable Parameters
• Key Function Monitoring
• Three Phase Voltage, Amperage, kW, kVA, and
kVAr
• Selectable Line to Line or Line to Neutral
Measurements
• Frequency
• Engine Speed
• Engine Coolant Temperature
• Engine Oil Pressure
• Engine Oil Temperature
• Battery Voltage
• Hourmeter
• Warning and Alarm Indication
• Diagnostics
• Maintenance Events/Information
SG200 | 14.2L | 200 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
232
Item5.
SPEC SHEET
3 of 6
CONFIGURABLE OPTIONS
ENGINE SYSTEM
○ Engine Coolant Heater
○ Baseframe Cover/Rodent Guard
○ 2 Stage Air Cleaner
○ Oil Heater
○ Air Filter Restriction Indicator
○ Radiator Stone Guard (Open Set Only)
○ Level 1 Fan and Belt Guards (Enclosed Units Only)
FUEL SYSTEM
○ NPT Flexible Fuel Line
ELECTRICAL SYSTEM
○ 10A UL Listed Battery Charger
○ Battery Warmer
ALTERNATOR SYSTEM
○ Alternator Upsizing
○ Anti-Condensation Heater
○ Tropical Coating
CIRCUIT BREAKER OPTIONS
○ Main Line Circuit Breaker
○ 2nd Main Line Circuit Breaker
○ 3rd Main Line Circuit Breaker
○ Shunt Trip and Auxiliary Contact
○ Electronic Trip Breakers
GENERATOR SET
○ Demand Response Rating
○ Extended Factory Testing (3-Phase Only)
○ 12 Position Load Center
○ Vapor Recovery Heater
ENCLOSURE
○ Weather Protected Enclosure
○ Level 1 Sound Attenuated
○ Level 2 Sound Attenuated
○ Level 2 Sound Attenuated with Motorized
Dampers
○ Level 3 Sound Attenuated (Steel Only)
○ Steel Enclosure
○ Aluminum Enclosure
○ Up to 200 MPH Wind Load Rating (Contact
Factory for Availability)
○ AC/DC Enclosure Lighting Kit
○ Enclosure Heaters (with Motorized Dampers Only)
○ IBC Certification
○ Door Open Alarm Switch
CONTROL SYSTEM
○ NFPA 110 Level 1 Compliant 21-Light Remote
Annunciator
○ Remote Relay Assembly (8 or 16)
○ Remote E-Stop (Break Glass-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Flush
Mount)
○ 10A Engine Run Relay
○ Ground Fault Annunciator
○ 100 dB Alarm Horn
○ 120V GFCI and 240V Outlets
○ Damper Alarm Contacts (with Motorized Dampers
Only)
WARRANTY (Standby Gensets Only)
○ 2 Year Extended Limited Warranty
○ 5 Year Extended Limited Warranty
○ 7 Year Extended Limited Warranty
○ 10 Year Extended Limited Warranty
ENGINEERED OPTIONS
ENGINE SYSTEM
○ Coolant Heater Ball Valves
○ Fluid Containment Pans
CONTROL SYSTEM
○ Battery Disconnect Switch
GENERATOR SET
○ Special Testing
○ Battery Box
CIRCUIT BREAKER OPTIONS
○ 4th Main Line Circuit Breaker
SG200 | 14.2L | 200 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
233
Item5.
SPEC SHEET
4 of 6
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
General
Make Generac
Cylinder # 6
Type In-line
Displacement - in³ (L) 864.71 (14.2)
Bore: in (mm) 5.31 (135)
Stroke: in (mm) 6.50 (165)
Compression Ratio 9.5:1
Intake Air Method Turbocharged/Aftercooled
Number of Main Bearings 7
Connecting Rods Steel Alloy
Cylinder Head Cast Iron
Cylinder Liners Ductile Iron
Ignition Electronic
Piston Type Aluminum
Crankshaft Type Ductile Iron
Lifter Type Solid
Intake Valve Material Special Heat-Resistant Steel
Exhaust Valve Material High Temperature Steel Alloy
Hardened Valve Seats High Temperature Steel Alloy
Engine Governing
Governor Electronic
Frequency Regulation (Steady State) ±0.25%
Lubrication System
Oil Pump Gear
Oil Filter Type Full-Flow Cartridge
Engine Oil Capacity: qt (L) 36.2 (34.3)
Cooling System
Cooling System Type Pressurized Closed Recovery
Fan Type Pusher
Fan Speed (RPM) 1,894
Fan Diameter - in (mm) 30 (762)
Fuel System
Fuel Type Natural Gas
Carburetor Down Draft
Secondary Fuel Regulator Standard
Fuel Shut Off Solenoid Standard
Operating Fuel Pressure- in H2O (kPa) 7 - 11 (1.7 - 2.7) *When designing the external fuel system, assume a 20% safety factor to the upper and lower limit of the specified fuel pressure range to account for site variation and measurement at the generator test port. Refer to Generac document 10000046207, latest rev. for proper gas supply design guidelines. (Contact Factory for Details) Engine Electrical System
System Voltage 24 VDC
Battery Charger Alternator 57.5 A
Battery Size See Battery Index 0161970SBY
Battery Voltage 24 VDC
Ground Polarity Negative (-)
ALTERNATOR SPECIFICATIONS
Standard Model K0200124Y21
Poles 4
Field Type Revolving
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distortion <5% (3-Phase)
Telephone Interference Factor (TIF) <50
Standard Excitation Permanent magnet
Bearings Sealed Ball
Coupling Direct via Flexible Disc
Prototype Short Circuit Test Yes
Voltage Regulator Type Digital
Number of Sensed Phases All
Regulation Accuracy (Steady State) ±0.25%
SG200 | 14.2L | 200 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
234
Item5.
SPEC SHEET
5 of 6
OPERATING DATA
POWER RATINGS - NATURAL GAS
Standby/Demand Response Prime
Single-Phase 120/240 VAC @1.0pf 200 kW/200 kVA Amps: 833 180 kW/180 kVA Amps: 750 Three-Phase 120/208 VAC @0.8pf 200 kW/250 kVA Amps: 695 180 kW/225 kVA Amps: 625 Three-Phase 120/240 VAC @0.8pf 200 kW/250 kVA Amps: 602 180 kW/225 kVA Amps: 542 Three-Phase 277/480 VAC @0.8pf 200 kW/250 kVA Amps: 301 180 kW/225 kVA Amps: 271 Three-Phase 346/600 VAC @0.8pf 200 kW/250 kVA Amps: 241 180 kW/225 kVA Amps: 217 MOTOR STARTING CAPABILITIES (skVA)
skVA vs. Voltage Dip
277/480 VAC 30% 208/240 VAC 30%
K0200124Y21 478 K0200124Y21 361
K0250124Y21 630 K0250124Y21 506
K0300124Y21 790 K0300124Y21 609
FUEL CONSUMPTION RATES*
Natural Gas – scfh (m³/hr)
Percent Load Standby/Demand Response Prime
25% 960 (27.2) 900 (25.5)
50% 1,440 (40.8) 1,320 (37.4)
75% 1,980 (56.1) 1,800 (51.0)
100% 2,460 (69.7) 2,280 (64.6)
*1.5X maximum site rated fuel consumption should be used for gas supply design practices.
Refer to Generac 10000046207, latest rev., for more information or contact factory for details.
COOLING
Standby/Demand Response Prime
Air Flow (Fan Air Flow Across Radiator) cfm (m³/min) 9,162 (259.4) 9,162 (259.4) Coolant Flow gpm (Lpm) 90 (340.7) 90 (340.7)
Coolant System Capacity gal (L) 11 (39.7) 11 (39.7)
Maximum Operating Ambient Temperature °F (°C) 122 (50) 122 (50) Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD See Bulletin No. 0199270SSD Maximum Additional Radiator Backpressure in H2O (kPa) 0.5 (0.12) 0.5 (0.12)
COMBUSTION AIR REQUIREMENTS
Standby/Demand Response Prime
Flow at rated power cfm - (m³ /min) 390 (11.0) 362 (10.3) ENGINE
Standby/
Demand
Response
Prime
Rated Engine Speed RPM 1,800 1,800
Horsepower at Rated kW** hp 304 274
Piston Speed ft/min
(m/min)
1,950 (594) 1,950 (594)
BMEP psi (kPa) 155 (1,065) 139 (959)
** See “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
EXHAUST
Standby/
Demand
Response
Prime
Exhaust Flow (Rated Output) cfm (m³/min) 1,327 (38) 1,213 (34) Max. Backpressure (Post
Silencer) inHg (kPa) 0.75 (2.54) 0.75 (2.54)
Exhaust Temp (Rated Output -
Post Silencer)
°F (°C) 1,378 (748) 1,350 (732)
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with BS5514 and DIN6271 standards.
Standby - See Bulletin 0187500SSB • Demand Response - See Bulletin 10000018250 • Prime - See Bulletin 0187510SSB SG200 | 14.2L | 200 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
235
Item5.
SPEC SHEET
Generac Power Systems, Inc. | S45 W29290 HWY. 59 | Waukesha, WI 53189 | generac.com ©2024 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Part No. 10000038976
Rev. E 11/01/2024
6 of 6
SG200 | 14.2L | 200 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DIMENSIONS AND WEIGHTS* DEMAND RESPONSE READY
L
L
L
L W
W
W
W
H
H
H
H
OPEN SET (Includes Exhaust Flex)
L x W x H - in (mm) 128.0 (3,251) x 52.9 (1,344) x 62.3 (1,582) Weight lbs (kg) 5,281 - 6,031 (2,395 - 2,735)
WEATHER PROTECTED ENCLOSURE
L x W x H - in (mm) 154.4 (3,922) x 54.0 (1,372) x 69.8 (1,773) Weight lbs (kg) Steel: 6,261 - 7,596 (2,839 - 3,445)
Aluminum: 5,795 - 6,786 (2,628 - 3,078)
LEVEL 1 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 179.9 (4,569) x 54.0 (1,372) x 69.8 (1,773) Weight lbs (kg) Steel 6,566 - 8,059 (2,978 - 3,655)
Aluminum: 5,926 - 7,000 (2,688 - 3,175)
LEVEL 2 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 154.4 (3,922) x 54.0 (1,372) x 93.3 (2,370) Weight lbs (kg) Steel: 6,801 - 8,632 (3,084 - 3,915)
Aluminum: 6,027 - 7,247 (2,733 - 3,287)
* All measurements are approximate and for estimation purposes only.
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings 236
Item5.
SPEC SHEET
1 of 6
Standby Power Rating
250 kW, 313 kVA, 60 Hz
Demand Response Rating
250 kW, 313 kVA, 60 Hz
Prime Power Rating
225 kW, 281 kVA, 60 Hz
**
** Offered on units sold in the U.S. and Canada Image used for illustration purposes only Codes and Standards
Not all codes and standards apply to all
configurations. Contact factory for details.
UL2200, UL6200, UL1236, UL489
CSA C22.2
TM
BS5514 and DIN 6271
®
SAE J1349
NFPA 37, 70, 99, 110
NEC700, 701, 702, 708
NEMA ICS10, MG1, 250, ICS6,
AB1
ANSI C62.41
IBC 2009, CBC 2010, IBC 2012,
ASCE 7-05, ASCE 7-10, ICC-ES
AC-156 (2012)
Powering a Smarter World
For over 65 years, Generac has been at the forefront of power generation, pioneering innovative solutions and unparalleled manufacturing excellence. At the heart of our reputation for superior quality lies our commitment to meticulously designing and manufacturing key components of our generators—ranging from alternators and enclosures to base tanks, control systems, and cutting-edge communications software.
Generac's gensets stand out for their unparalleled versatility and reliability. Engineered to offer a wide range of options and configurations, they are tailored to meet the unique demands of virtually any application, seamlessly adapting to its complexity. Our commitment to reliability drives us to globally source only the most dependable engines, selected through stringent criteria for optimal performance under the toughest industrial conditions.
Beyond the sale, Generac's dedication to our customers extends to comprehensive service support, for peace of mind and reliability long after your purchase. Our commitment is to not only provide state-of-the-art power solutions but also enduring success and satisfaction of our customers through ongoing support and service excellence.
SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
237
Item5.
SPEC SHEET
2 of 6
STANDARD FEATURES
ENGINE SYSTEM
• Oil Drain Extension
• Air Cleaner
• Fan Guard (Open Sets Only)
• Stainless Steel Flexible Exhaust Connection
• Factory Filled Oil and Coolant
• Radiator Duct Adapter (Open Set Only)
• Critical Silencer (Enclosed Units Only)
• Oil Temperature Indication and Alarm
FUEL SYSTEM
• NPT Fuel Connection on Frame
• Primary and Secondary Fuel Shutoff
COOLING SYSTEM
• Closed Coolant Recovery System
• UV/Ozone Resistant Hoses
• Factory-Installed Radiator
• 50/50 Ethylene Glycol Antifreeze
• Radiator Drain Extension
ELECTRICAL SYSTEM
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ENCLOSURE (If Selected)
• Rust-Proof Fasteners with Nylon Washers to
Protect Finish
• High Performance Sound-Absorbing Material
(Sound Attenuated Enclosures)
• Gasketed Doors
• Upward Facing Discharge Hood (Radiator and
Exhaust)
• Stainless Steel Lift Off Door Hinges
• Stainless Steel Lockable Handles
• RhinoCoat™ - Textured Polyester Powder Coat
Paint
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Wrapped Exhaust Piping
• Standard Factory Testing
• 2 Year Limited Warranty (Standby and Demand
Response Rated Units)
• 1 Year Limited Warranty (Prime Rated Units)
• Silencer Mounted in the Discharge Hood
(Enclosed Units Only)
• Ready to Accept Full Load in <10 Seconds
ALTERNATOR SYSTEM
• UL2200 GENprotect™
• Class H Insulation Material
• 2/3 Pitch
• Skewed Stator
• Permanent Magnet Excitation
• Sealed Bearing
• Amortisseur Winding
• Full Load Capacity Alternator
CONTROL SYSTEM
Power Zone® Pro Sync Controller
Program Functions
• NFPA 110 Level 1 Compliant
• Engine Protective Functions
• Alternator Protective Functions
• Digital Engine Governor Control
• Digital Voltage Regulator
• Multiple Programmable Inputs and Outputs
• Remote Display Capability
• Remote Communication via Modbus® RTU,
Modbus TCP/IP, and Ethernet 10/100
• Alarm and Event Logging with Real Time
Stamping
• Expandable Analog and Digital Inputs and Outputs
• Remote Wireless Software Update Capable
• BMS and Remote Telemetry
• Built-In Programmable Logic Eliminates the Need
for External Controllers Under Most Conditions
• Ethernet Based Communications Between
Generators
• Programmable I/O Channel Properties
• Built-In Diagnostics
• Arc Flash Maintenance Mode (When Correctly
Equipped)
Alarms and Warnings
• Low Oil Pressure
• Low Coolant Level
• High/Low Coolant Temperature
• Sensor Failure
• Oil Temperature
• Over/Under Speed
• Over/Under Voltage
• Over/Under Frequency
• Over/Under Current
• Over Load
• High/Low Battery Voltage
• Battery Charger Current
• Phase to Phase and Phase to Neutral Short
Circuits (I2T Algorithm)
7 Inch Color Touch Screen Display
• Resistive Color Touch Screen
• Sunlight Readable (1400 NITS)
• Easily Identifiable Icons
• Multi-Lingual
• On Screen Editable Parameters
• Key Function Monitoring
• Three Phase Voltage, Amperage, kW, kVA, and
kVAr
• Selectable Line to Line or Line to Neutral
Measurements
• Frequency
• Engine Speed
• Engine Coolant Temperature
• Engine Oil Pressure
• Engine Oil Temperature
• Battery Voltage
• Hourmeter
• Warning and Alarm Indication
• Diagnostics
• Maintenance Events/Information
SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
238
Item5.
SPEC SHEET
3 of 6
CONFIGURABLE OPTIONS
ENGINE SYSTEM
○ Engine Coolant Heater
○ Baseframe Cover/Rodent Guard
○ 2 Stage Air Cleaner
○ Oil Heater
○ Air Filter Restriction Indicator
○ Radiator Stone Guard (Open Set Only)
○ Level 1 Fan and Belt Guards (Enclosed Units Only)
FUEL SYSTEM
○ NPT Flexible Fuel Line
ELECTRICAL SYSTEM
○ 10A UL Listed Battery Charger
○ Battery Warmer
ALTERNATOR SYSTEM
○ Alternator Upsizing
○ Anti-Condensation Heater
○ Tropical Coating
CIRCUIT BREAKER OPTIONS
○ Main Line Circuit Breaker
○ 2nd Main Line Circuit Breaker
○ 3rd Main Line Circuit Breaker
○ Shunt Trip and Auxiliary Contact
○ Electronic Trip Breakers
GENERATOR SET
○ Demand Response Rating
○ Extended Factory Testing (3-Phase Only)
○ 12 Position Load Center
○ Vapor Recovery Heater
ENCLOSURE
○ Weather Protected Enclosure
○ Level 1 Sound Attenuated
○ Level 2 Sound Attenuated
○ Level 2 Sound Attenuated with Motorized
Dampers
○ Level 3 Sound Attenuated (Steel Only)
○ Steel Enclosure
○ Aluminum Enclosure
○ Up to 200 MPH Wind Load Rating (Contact
Factory for Availability)
○ AC/DC Enclosure Lighting Kit
○ Enclosure Heaters (with Motorized Dampers Only)
○ IBC Seismic Certification
○ Door Open Alarm Switch
CONTROL SYSTEM
○ NFPA 110 Level 1 Compliant 21-Light Remote
Annunciator
○ Remote Relay Assembly (8 or 16)
○ Remote E-Stop (Break Glass-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Flush
Mount)
○ 10A Engine Run Relay
○ Ground Fault Annunciator
○ 100 dB Alarm Horn
○ Damper Alarm Contacts (with Motorized Dampers
Only)
○ 120V GFCI and 240V Outlets
WARRANTY (Standby Gensets Only)
○ 2 Year Extended Limited Warranty
○ 5 Year Extended Limited Warranty
○ 7 Year Extended Limited Warranty
○ 10 Year Extended Limited Warranty
ENGINEERED OPTIONS
ENGINE SYSTEM
○ Coolant Heater Ball Valves
○ Fluid Containment Pans
CONTROL SYSTEM
○ Battery Disconnect Switch
CIRCUIT BREAKER OPTIONS
○ 4th Main Line Circuit Breaker
GENERATOR SET
○ Special Testing
○ Battery Box
SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
239
Item5.
SPEC SHEET
4 of 6
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
General
Make Generac
Cylinder # 6
Type In-line
Displacement - in³ (L) 864.71 (14.2)
Bore: in (mm) 5.31 (135)
Stroke: in (mm) 6.50 (165)
Compression Ratio 9.5:1
Intake Air Method Turbocharged/Aftercooled
Number of Main Bearings 7
Connecting Rods Steel Alloy
Cylinder Head Cast Iron
Cylinder Liners Ductile Iron
Ignition Electronic
Piston Type Aluminum
Crankshaft Type Ductile Iron
Lifter Type Solid
Intake Valve Material Special Heat-Resistant Steel
Exhaust Valve Material High Temperature Steel Alloy
Hardened Valve Seats High Temperature Steel Alloy
Engine Governing
Governor Electronic
Frequency Regulation (Steady State) ±0.25%
Lubrication System
Oil Pump Type Gear
Oil Filter Type Full Flow Spin-On Cartridge
Engine Oil Capacity: qt (L) 36.2 (34.3)
Cooling System
Cooling System Type Pressurized Closed Recovery
Fan Type Pusher
Fan Speed (RPM) 1,894
Fan Diameter - in (mm) 30 (762)
Fuel System
Fuel Type Natural Gas
Carburetor Down Draft
Secondary Fuel Regulator Standard
Fuel Shut Off Solenoid Standard
Operating Fuel Pressure- in H2O (kPa) 7 - 11 (1.7 - 2.7) *When designing the external fuel system, assume a 20% safety factor to the upper and lower limit of the specified fuel pressure range to account for site variation and measurement at the generator test port.Refer to Generac document 10000046207. Latest rev. for proper gas supply design guidelines. (Contact Factory for Details)
Engine Electrical System
System Voltage 24 VDC
Battery Charger Alternator 57.5 A
Battery Size See Battery Index 0161970SBY
Battery Voltage 24 VDC
Ground Polarity Negative (-)
ALTERNATOR SPECIFICATIONS
Standard Model K0250124Y21
Poles 4
Field Type Revolving
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distortion <5%
Telephone Interference Factor (TIF) <50
Standard Excitation Permanent Magnet
Bearings Single Sealed Ball
Coupling Direct via Flexible Disc
Prototype Short Circuit Test Yes
Voltage Regulator Type Full Digital
Number of Sensed Phases All
Regulation Accuracy (Steady State) ±0.25%
SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
240
Item5.
SPEC SHEET
5 of 6
OPERATING DATA
POWER RATINGS - NATURAL GAS
Standby/Demand Response Prime
Three-Phase 120/208 VAC @0.8pf 250 kW/313 kVA Amps: 868 225 kW/281 kVA Amps: 782 Three-Phase 120/240 VAC @0.8pf 250 kW/313 kVA Amps: 753 225 kW/281 kVA Amps: 677 Three-Phase 277/480 VAC @0.8pf 250 kW/313 kVA Amps: 376 225 kW/281 kVA Amps: 339 Three-Phase 346/600 VAC @0.8pf 250 kW/313 kVA Amps: 301 225 kW/281 kVA Amps: 271 MOTOR STARTING CAPABILITIES (skVA)
skVA vs. Voltage Dip
277/480 VAC 30% 208/240 VAC 30%
K0250124Y21 630 K0250124Y21 506
K0300124Y21 790 K0300124Y21 609
FUEL CONSUMPTION RATES*
Natural Gas – scfh (m³/hr)
Percent Load Standby/Demand Response Prime
25% 1,020 (28.9) 990 (28.0)
50% 1,620 (45.9) 1,260 (35.7)
75% 2,520 (71.4) 1,980 (56.1)
100% 3,180 (90.0) 2,700 (76.5)
* 1.5X maximum site rated fuel consumption should be used for gas supply design practices.
Refer to Generac 10000046207, latest rev., for more information or contact factory for details.
COOLING
Standby/Demand Response Prime
Air Flow (Fan Air Flow Across Radiator) cfm (m³/min) 10,078 (285.4) 10,078 (285.4) Coolant Flow gpm (Lpm) 90 (340.7) 90 (340.7)
Coolant System Capacity gal (L) 15 (54.9) 15 (54.9)
Maximum Operating Ambient Temperature °F (°C) 122 (50) 122 (50) Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD See Bulletin No. 0199270SSD Maximum Additional Radiator Backpressure in H2O (kPa) 0.5 (0.12) 0.5 (0.12)
COMBUSTION AIR REQUIREMENTS
Standby/Demand Response Prime
Flow at rated power cfm - (m³/min) 506 (14.3) 455 (12.9) ENGINE
Standby/Demand
Response
Prime
Rated Engine Speed RPM 1,800 1,800
Horsepower at Rated
kW**
hp 375 337
Piston Speed ft/min (m/
min)
1,950 (594) 1,950 (594)
BMEP psi (kPa) 190 (1,313) 171 (1,182)
** See “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
EXHAUST
Standby/Demand
Response
Prime
Exhaust Flow (Rated
Output) cfm (m³/min) 1,703 (48) 1,517 (43)
Max. Backpressure (Post
Silencer)
inHg (kPa) 0.75 (2.54) 0.75 (2.54)
Exhaust Temp (Rated
Output - Post Silencer) °F (°C) 1,357 (736) 1,340 (727) Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with BS5514 and DIN6271 standards.
Standby - See Bulletin 0187500SSB • Demand Response - See Bulletin 10000018250 • Prime - See Bulletin 0187510SSB SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
241
Item5.
SPEC SHEET
Generac Power Systems, Inc. | S45 W29290 HWY. 59 | Waukesha, WI 53189 | generac.com ©2024 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Part No. 10000038995
Rev. E 10/29/2024
6 of 6
SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DIMENSIONS AND WEIGHTS* DEMAND RESPONSE READY
OPEN SET (Includes Exhaust Flex)
L x W x H - in (mm) 136.0 (3,454) x 57.1 (1,450) x 67.9 (1,725) Weight - lbs (kg) 5,883 - 6,031 (2,668 - 2,735)
WEATHER PROTECTED ENCLOSURE
L x W x H - in (mm) 174.7 (4,437) x 57.5 (1,461) x 77.8 (1,976) Weight - lbs (kg) Steel: 7,448 - 7,596 (3,378 - 3,445)
Aluminum: 6,654 - 6,801 (3,018 - 3,084)
LEVEL 1 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 200.2 (5,085) x 57.5 (1,461) x 77.8 (1,976) Weight - lbs (kg) Steel 7,911 - 8,059 (3,588 - 3,655)
Aluminum: 6,853 - 7,000 (3,108 - 3,175)
LEVEL 2 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 180.6 (4,587) x 57.5 (1,461) x 111.3 (2,827) Weight - lbs (kg) Steel: 8,484 - 8,632 (3,848 - 3,915)
Aluminum: 7,099 - 7,247 (3,220 - 3,287)
LEVEL 3 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 207.3 (5,265) x 63.7 (1,618) x 128.9 (3,274) Weight - lbs (kg) 10,840 - 10,990 (4,916 - 4,984)
* All measurements are approximate and for estimation purposes only.
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings 242
Item5.
SPEC SHEET
1 of 6
Standby Power Rating
250 kW, 313 kVA, 60 Hz
Demand Response Rating
250 kW, 313 kVA, 60 Hz
Prime Power Rating
225 kW, 281 kVA, 60 Hz
**
** Offered on units sold in the U.S. and Canada Image used for illustration purposes only Codes and Standards
Not all codes and standards apply to all
configurations. Contact factory for details.
UL2200, UL6200, UL1236, UL489
CSA C22.2
TM
BS5514 and DIN 6271
®
SAE J1349
NFPA 37, 70, 99, 110
NEC700, 701, 702, 708
NEMA ICS10, MG1, 250, ICS6,
AB1
ANSI C62.41
IBC 2009, CBC 2010, IBC 2012,
ASCE 7-05, ASCE 7-10, ICC-ES
AC-156 (2012)
Powering a Smarter World
For over 65 years, Generac has been at the forefront of power generation, pioneering innovative solutions and unparalleled manufacturing excellence. At the heart of our reputation for superior quality lies our commitment to meticulously designing and manufacturing key components of our generators—ranging from alternators and enclosures to base tanks, control systems, and cutting-edge communications software.
Generac's gensets stand out for their unparalleled versatility and reliability. Engineered to offer a wide range of options and configurations, they are tailored to meet the unique demands of virtually any application, seamlessly adapting to its complexity. Our commitment to reliability drives us to globally source only the most dependable engines, selected through stringent criteria for optimal performance under the toughest industrial conditions.
Beyond the sale, Generac's dedication to our customers extends to comprehensive service support, for peace of mind and reliability long after your purchase. Our commitment is to not only provide state-of-the-art power solutions but also enduring success and satisfaction of our customers through ongoing support and service excellence.
SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
243
Item5.
SPEC SHEET
2 of 6
STANDARD FEATURES
ENGINE SYSTEM
• Oil Drain Extension
• Air Cleaner
• Fan Guard (Open Sets Only)
• Stainless Steel Flexible Exhaust Connection
• Factory Filled Oil and Coolant
• Radiator Duct Adapter (Open Set Only)
• Critical Silencer (Enclosed Units Only)
• Oil Temperature Indication and Alarm
FUEL SYSTEM
• NPT Fuel Connection on Frame
• Primary and Secondary Fuel Shutoff
COOLING SYSTEM
• Closed Coolant Recovery System
• UV/Ozone Resistant Hoses
• Factory-Installed Radiator
• 50/50 Ethylene Glycol Antifreeze
• Radiator Drain Extension
ELECTRICAL SYSTEM
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ENCLOSURE (If Selected)
• Rust-Proof Fasteners with Nylon Washers to
Protect Finish
• High Performance Sound-Absorbing Material
(Sound Attenuated Enclosures)
• Gasketed Doors
• Upward Facing Discharge Hood (Radiator and
Exhaust)
• Stainless Steel Lift Off Door Hinges
• Stainless Steel Lockable Handles
• RhinoCoat™ - Textured Polyester Powder Coat
Paint
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Wrapped Exhaust Piping
• Standard Factory Testing
• 2 Year Limited Warranty (Standby and Demand
Response Rated Units)
• 1 Year Limited Warranty (Prime Rated Units)
• Silencer Mounted in the Discharge Hood
(Enclosed Units Only)
• Ready to Accept Full Load in <10 Seconds
ALTERNATOR SYSTEM
• UL2200 GENprotect™
• Class H Insulation Material
• 2/3 Pitch
• Skewed Stator
• Permanent Magnet Excitation
• Sealed Bearing
• Amortisseur Winding
• Full Load Capacity Alternator
CONTROL SYSTEM
Power Zone® Pro Sync Controller
Program Functions
• NFPA 110 Level 1 Compliant
• Engine Protective Functions
• Alternator Protective Functions
• Digital Engine Governor Control
• Digital Voltage Regulator
• Multiple Programmable Inputs and Outputs
• Remote Display Capability
• Remote Communication via Modbus® RTU,
Modbus TCP/IP, and Ethernet 10/100
• Alarm and Event Logging with Real Time
Stamping
• Expandable Analog and Digital Inputs and Outputs
• Remote Wireless Software Update Capable
• BMS and Remote Telemetry
• Built-In Programmable Logic Eliminates the Need
for External Controllers Under Most Conditions
• Ethernet Based Communications Between
Generators
• Programmable I/O Channel Properties
• Built-In Diagnostics
• Arc Flash Maintenance Mode (When Correctly
Equipped)
Alarms and Warnings
• Low Oil Pressure
• Low Coolant Level
• High/Low Coolant Temperature
• Sensor Failure
• Oil Temperature
• Over/Under Speed
• Over/Under Voltage
• Over/Under Frequency
• Over/Under Current
• Over Load
• High/Low Battery Voltage
• Battery Charger Current
• Phase to Phase and Phase to Neutral Short
Circuits (I2T Algorithm)
7 Inch Color Touch Screen Display
• Resistive Color Touch Screen
• Sunlight Readable (1400 NITS)
• Easily Identifiable Icons
• Multi-Lingual
• On Screen Editable Parameters
• Key Function Monitoring
• Three Phase Voltage, Amperage, kW, kVA, and
kVAr
• Selectable Line to Line or Line to Neutral
Measurements
• Frequency
• Engine Speed
• Engine Coolant Temperature
• Engine Oil Pressure
• Engine Oil Temperature
• Battery Voltage
• Hourmeter
• Warning and Alarm Indication
• Diagnostics
• Maintenance Events/Information
SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
244
Item5.
SPEC SHEET
3 of 6
CONFIGURABLE OPTIONS
ENGINE SYSTEM
○ Engine Coolant Heater
○ Baseframe Cover/Rodent Guard
○ 2 Stage Air Cleaner
○ Oil Heater
○ Air Filter Restriction Indicator
○ Radiator Stone Guard (Open Set Only)
○ Level 1 Fan and Belt Guards (Enclosed Units Only)
FUEL SYSTEM
○ NPT Flexible Fuel Line
ELECTRICAL SYSTEM
○ 10A UL Listed Battery Charger
○ Battery Warmer
ALTERNATOR SYSTEM
○ Alternator Upsizing
○ Anti-Condensation Heater
○ Tropical Coating
CIRCUIT BREAKER OPTIONS
○ Main Line Circuit Breaker
○ 2nd Main Line Circuit Breaker
○ 3rd Main Line Circuit Breaker
○ Shunt Trip and Auxiliary Contact
○ Electronic Trip Breakers
GENERATOR SET
○ Demand Response Rating
○ Extended Factory Testing (3-Phase Only)
○ 12 Position Load Center
○ Vapor Recovery Heater
ENCLOSURE
○ Weather Protected Enclosure
○ Level 1 Sound Attenuated
○ Level 2 Sound Attenuated
○ Level 2 Sound Attenuated with Motorized
Dampers
○ Level 3 Sound Attenuated (Steel Only)
○ Steel Enclosure
○ Aluminum Enclosure
○ Up to 200 MPH Wind Load Rating (Contact
Factory for Availability)
○ AC/DC Enclosure Lighting Kit
○ Enclosure Heaters (with Motorized Dampers Only)
○ IBC Seismic Certification
○ Door Open Alarm Switch
CONTROL SYSTEM
○ NFPA 110 Level 1 Compliant 21-Light Remote
Annunciator
○ Remote Relay Assembly (8 or 16)
○ Remote E-Stop (Break Glass-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Flush
Mount)
○ 10A Engine Run Relay
○ Ground Fault Annunciator
○ 100 dB Alarm Horn
○ Damper Alarm Contacts (with Motorized Dampers
Only)
○ 120V GFCI and 240V Outlets
WARRANTY (Standby Gensets Only)
○ 2 Year Extended Limited Warranty
○ 5 Year Extended Limited Warranty
○ 7 Year Extended Limited Warranty
○ 10 Year Extended Limited Warranty
ENGINEERED OPTIONS
ENGINE SYSTEM
○ Coolant Heater Ball Valves
○ Fluid Containment Pans
CONTROL SYSTEM
○ Battery Disconnect Switch
CIRCUIT BREAKER OPTIONS
○ 4th Main Line Circuit Breaker
GENERATOR SET
○ Special Testing
○ Battery Box
SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
245
Item5.
SPEC SHEET
4 of 6
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
General
Make Generac
Cylinder # 6
Type In-line
Displacement - in³ (L) 864.71 (14.2)
Bore: in (mm) 5.31 (135)
Stroke: in (mm) 6.50 (165)
Compression Ratio 9.5:1
Intake Air Method Turbocharged/Aftercooled
Number of Main Bearings 7
Connecting Rods Steel Alloy
Cylinder Head Cast Iron
Cylinder Liners Ductile Iron
Ignition Electronic
Piston Type Aluminum
Crankshaft Type Ductile Iron
Lifter Type Solid
Intake Valve Material Special Heat-Resistant Steel
Exhaust Valve Material High Temperature Steel Alloy
Hardened Valve Seats High Temperature Steel Alloy
Engine Governing
Governor Electronic
Frequency Regulation (Steady State) ±0.25%
Lubrication System
Oil Pump Type Gear
Oil Filter Type Full Flow Spin-On Cartridge
Engine Oil Capacity: qt (L) 36.2 (34.3)
Cooling System
Cooling System Type Pressurized Closed Recovery
Fan Type Pusher
Fan Speed (RPM) 1,894
Fan Diameter - in (mm) 30 (762)
Fuel System
Fuel Type Natural Gas
Carburetor Down Draft
Secondary Fuel Regulator Standard
Fuel Shut Off Solenoid Standard
Operating Fuel Pressure- in H2O (kPa) 7 - 11 (1.7 - 2.7) *When designing the external fuel system, assume a 20% safety factor to the upper and lower limit of the specified fuel pressure range to account for site variation and measurement at the generator test port.Refer to Generac document 10000046207. Latest rev. for proper gas supply design guidelines. (Contact Factory for Details)
Engine Electrical System
System Voltage 24 VDC
Battery Charger Alternator 57.5 A
Battery Size See Battery Index 0161970SBY
Battery Voltage 24 VDC
Ground Polarity Negative (-)
ALTERNATOR SPECIFICATIONS
Standard Model K0250124Y21
Poles 4
Field Type Revolving
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distortion <5%
Telephone Interference Factor (TIF) <50
Standard Excitation Permanent Magnet
Bearings Single Sealed Ball
Coupling Direct via Flexible Disc
Prototype Short Circuit Test Yes
Voltage Regulator Type Full Digital
Number of Sensed Phases All
Regulation Accuracy (Steady State) ±0.25%
SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
246
Item5.
SPEC SHEET
5 of 6
OPERATING DATA
POWER RATINGS - NATURAL GAS
Standby/Demand Response Prime
Three-Phase 120/208 VAC @0.8pf 250 kW/313 kVA Amps: 868 225 kW/281 kVA Amps: 782 Three-Phase 120/240 VAC @0.8pf 250 kW/313 kVA Amps: 753 225 kW/281 kVA Amps: 677 Three-Phase 277/480 VAC @0.8pf 250 kW/313 kVA Amps: 376 225 kW/281 kVA Amps: 339 Three-Phase 346/600 VAC @0.8pf 250 kW/313 kVA Amps: 301 225 kW/281 kVA Amps: 271 MOTOR STARTING CAPABILITIES (skVA)
skVA vs. Voltage Dip
277/480 VAC 30% 208/240 VAC 30%
K0250124Y21 630 K0250124Y21 506
K0300124Y21 790 K0300124Y21 609
FUEL CONSUMPTION RATES*
Natural Gas – scfh (m³/hr)
Percent Load Standby/Demand Response Prime
25% 1,020 (28.9) 990 (28.0)
50% 1,620 (45.9) 1,260 (35.7)
75% 2,520 (71.4) 1,980 (56.1)
100% 3,180 (90.0) 2,700 (76.5)
* 1.5X maximum site rated fuel consumption should be used for gas supply design practices.
Refer to Generac 10000046207, latest rev., for more information or contact factory for details.
COOLING
Standby/Demand Response Prime
Air Flow (Fan Air Flow Across Radiator) cfm (m³/min) 10,078 (285.4) 10,078 (285.4) Coolant Flow gpm (Lpm) 90 (340.7) 90 (340.7)
Coolant System Capacity gal (L) 15 (54.9) 15 (54.9)
Maximum Operating Ambient Temperature °F (°C) 122 (50) 122 (50) Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD See Bulletin No. 0199270SSD Maximum Additional Radiator Backpressure in H2O (kPa) 0.5 (0.12) 0.5 (0.12)
COMBUSTION AIR REQUIREMENTS
Standby/Demand Response Prime
Flow at rated power cfm - (m³/min) 506 (14.3) 455 (12.9) ENGINE
Standby/Demand
Response
Prime
Rated Engine Speed RPM 1,800 1,800
Horsepower at Rated
kW**
hp 375 337
Piston Speed ft/min (m/
min)
1,950 (594) 1,950 (594)
BMEP psi (kPa) 190 (1,313) 171 (1,182)
** See “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
EXHAUST
Standby/Demand
Response
Prime
Exhaust Flow (Rated
Output) cfm (m³/min) 1,703 (48) 1,517 (43)
Max. Backpressure (Post
Silencer)
inHg (kPa) 0.75 (2.54) 0.75 (2.54)
Exhaust Temp (Rated
Output - Post Silencer) °F (°C) 1,357 (736) 1,340 (727) Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with BS5514 and DIN6271 standards.
Standby - See Bulletin 0187500SSB • Demand Response - See Bulletin 10000018250 • Prime - See Bulletin 0187510SSB SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
247
Item5.
SPEC SHEET
Generac Power Systems, Inc. | S45 W29290 HWY. 59 | Waukesha, WI 53189 | generac.com ©2024 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Part No. 10000038995
Rev. E 10/29/2024
6 of 6
SG250 | 14.2 L | 250 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DIMENSIONS AND WEIGHTS* DEMAND RESPONSE READY
OPEN SET (Includes Exhaust Flex)
L x W x H - in (mm) 136.0 (3,454) x 57.1 (1,450) x 67.9 (1,725) Weight - lbs (kg) 5,883 - 6,031 (2,668 - 2,735)
WEATHER PROTECTED ENCLOSURE
L x W x H - in (mm) 174.7 (4,437) x 57.5 (1,461) x 77.8 (1,976) Weight - lbs (kg) Steel: 7,448 - 7,596 (3,378 - 3,445)
Aluminum: 6,654 - 6,801 (3,018 - 3,084)
LEVEL 1 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 200.2 (5,085) x 57.5 (1,461) x 77.8 (1,976) Weight - lbs (kg) Steel 7,911 - 8,059 (3,588 - 3,655)
Aluminum: 6,853 - 7,000 (3,108 - 3,175)
LEVEL 2 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 180.6 (4,587) x 57.5 (1,461) x 111.3 (2,827) Weight - lbs (kg) Steel: 8,484 - 8,632 (3,848 - 3,915)
Aluminum: 7,099 - 7,247 (3,220 - 3,287)
LEVEL 3 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 207.3 (5,265) x 63.7 (1,618) x 128.9 (3,274) Weight - lbs (kg) 10,840 - 10,990 (4,916 - 4,984)
* All measurements are approximate and for estimation purposes only.
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings 248
Item5.
SPEC SHEET
1 of 6
Standby Power Rating
300 kW, 375 kVA, 60 Hz
Demand Response Rating
300 kW, 375 kVA, 60 Hz
Prime Power Rating
270 kW, 338 kVA, 60 Hz
**
** Offered on units sold in the U.S. and Canada
Image used for illustration purposes only
Codes and Standards
Not all codes and standards apply to all
configurations. Contact factory for details.
UL2200, UL6200, UL1236, UL489
CSA C22.2
TM
BS5514 and DIN 6271
®
SAE J1349
NFPA 37, 70, 99, 110
NEC700, 701, 702, 708
NEMA ICS10, MG1, 250, ICS6,
AB1
ANSI C62.41
IBC 2009, CBC 2010, IBC 2012,
ASCE 7-05, ASCE 7-10, ICC-ES
AC-156 (2012)
Powering Ahead
Generac provides superior quality by designing and manufacturing most of its generator components, such as alternators, enclosures, control systems and communications software. Generac also makes its own spark-ignited engines, and they can be found on every Generac gaseous-fueled generator. We engineer and manufacture them from the block up — all at our facilities throughout Wisconsin. Applying natural gas and LP-fueled engines to generators requires advanced engineering expertise for reliability, durability and necessary performance. By designing specifically for these dry, hotter-burning fuels, the engines last longer and require less maintenance. Building our own engines also means we control every step of the supply chain and delivery process, so you benefit from single-source responsibility.
Plus, Generac Industrial Power’s distribution network provides all parts and service so owners don’t have to deal with third-party suppliers. It all leads to a positive owner experience and higher confidence level. Generac spark-ignited engines give more options in commercial and industrial generator applications as well as extended run time from utility-supplied natural gas.
SG300 | 14.2L | 300 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
249
Item5.
SPEC SHEET
2 of 6
STANDARD FEATURES
ENGINE SYSTEM
• Oil Drain Extension
• Air Cleaner
• Fan Guard
• Stainless Steel Flexible Exhaust Connection
• Factory Filled Oil and Coolant
• Radiator Duct Adapter (Open Set Only)
• Critical Silencer (Enclosed Units Only)
• Oil Temperature Indication and Alarm
FUEL SYSTEM
• NPT Fuel Connection on Frame
• Primary and Secondary Fuel Shutoff
COOLING SYSTEM
• Closed Coolant Recovery System
• UV/Ozone Resistant Hoses
• Factory-Installed Radiator
• 50/50 Ethylene Glycol Antifreeze
• Radiator Drain Extension
ELECTRICAL SYSTEM
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ENCLOSURE (If Selected)
• Rust-Proof Fasteners with Nylon Washers to
Protect Finish
• High Performance Sound-Absorbing Material
(Sound Attenuated Enclosures)
• Gasketed Doors
• Upward Facing Discharge Hood (Radiator and
Exhaust)
• Stainless Steel Lift Off Door Hinges
• Stainless Steel Lockable Handles
• RhinoCoat™ - Textured Polyester Powder Coat
Paint
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Wrapped Exhaust Piping
• Standard Factory Testing
• 2 Year Limited Warranty (Standby Rated Units)
• Ready to Accept Full Load in <10 Seconds
ALTERNATOR SYSTEM
• UL2200 GENprotect™
• Class H Insulation Material
• 2/3 Pitch
• Skewed Stator
• Permanent Magnet Excitation
• Sealed Bearing
• Amortisseur Winding
• Full Load Capacity Alternator
CONTROL SYSTEM
Power Zone® Pro Sync Controller
Program Functions
• NFPA 110 Level 1 Compliant
• Engine Protective Functions
• Alternator Protective Functions
• Digital Engine Governor Control
• Digital Voltage Regulator
• Multiple Programmable Inputs and Outputs
• Remote Display Capability
• Remote Communication via Modbus® RTU,
Modbus TCP/IP, and Ethernet 10/100
• Alarm and Event Logging with Real Time
Stamping
• Expandable Analog and Digital Inputs and Outputs
• Remote Wireless Software Update Capable
• BMS and Remote Telemetry
• Built-In Programmable Logic Eliminates the Need
for External Controllers Under Most Conditions
• Ethernet Based Communications Between
Generators
• Programmable I/O Channel Properties
• Built-In Diagnostics
• Arc Flash Maintenance Mode (When Correctly
Equipped)
Alarms and Warnings
• Low Oil Pressure
• Low Coolant Level
• High/Low Coolant Temperature
• Sensor Failure
• Oil Temperature
• Over/Under Speed
• Over/Under Voltage
• Over/Under Frequency
• Over/Under Current
• Over Load
• High/Low Battery Voltage
• Battery Charger Current
• Phase to Phase and Phase to Neutral Short
Circuits (I2T Algorithm)
7 Inch Color Touch Screen Display
• Resistive Color Touch Screen
• Sunlight Readable (1400 NITS)
• Easily Identifiable Icons
• Multi-Lingual
• On Screen Editable Parameters
• Key Function Monitoring
• Three Phase Voltage, Amperage, kW, kVA, and
kVAr
• Selectable Line to Line or Line to Neutral
Measurements
• Frequency
• Engine Speed
• Engine Coolant Temperature
• Engine Oil Pressure
• Engine Oil Temperature
• Battery Voltage
• Hourmeter
• Warning and Alarm Indication
• Diagnostics
• Maintenance Events/Information
SG300 | 14.2L | 300 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
250
Item5.
SPEC SHEET
3 of 6
CONFIGURABLE OPTIONS
ENGINE SYSTEM
○ Engine Coolant Heater
○ Baseframe Cover/Rodent Guard
○ 2 Stage Air Cleaner
○ Oil Heater
○ Air Filter Restriction Indicator
○ Radiator Stone Guard (Open Set Only)
○ Level 1 Fan and Belt Guards
FUEL SYSTEM
○ NPT Flexible Fuel Line
ELECTRICAL SYSTEM
○ 10A UL Listed Battery Charger
○ Battery Warmer
ALTERNATOR SYSTEM
○ Alternator Upsizing
○ Anti-Condensation Heater
○ Tropical Coating
CIRCUIT BREAKER OPTIONS
○ Main Line Circuit Breaker
○ 2nd Main Line Circuit Breaker
○ 3rd Main Line Circuit Breaker
○ Shunt Trip and Auxiliary Contact
○ Electronic Trip Breakers
GENERATOR SET
○ Demand Response Rating
○ Extended Factory Testing (3-Phase Only)
○ 12 Position Load Center
○ Vapor Recovery Heater
ENCLOSURE
○ Weather Protected Enclosure
○ Level 1 Sound Attenuated
○ Level 2 Sound Attenuated
○ Level 2 Sound Attenuated with Motorized
Dampers
○ Level 3 Sound Attenuated (Steel Only)
○ Steel Enclosure
○ Aluminum Enclosure
○ Up to 200 MPH Wind Load Rating (Contact
Factory for Availability)
○ AC/DC Enclosure Lighting Kit
○ Enclosure Heaters
○ IBC Seismic Certification
○ Door Open Alarm Switch
CONTROL SYSTEM
○ NFPA 110 Level 1 Compliant 21-Light Remote
Annunciator
○ Remote Relay Assembly (8 or 16)
○ Remote E-Stop (Break Glass-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Surface
Mount)
○ Remote E-Stop (Red Mushroom-Type, Flush
Mount)
○ 10A Engine Run Relay
○ Ground Fault Annunciator
○ 120V GFCI and 240V Outlets
○ Damper Alarm Contacts (with Motorized Dampers
Only)
○ 100 dB Alarm Horn
WARRANTY (Standby Gensets Only)
○ 2 Year Extended Limited Warranty
○ 5 Year Extended Limited Warranty
○ 7 Year Extended Limited Warranty
○ 10 Year Extended Limited Warranty
ENGINEERED OPTIONS
ENGINE SYSTEM
○ Fluid Containment Pans
CONTROL SYSTEM
○ Battery Disconnect Switch
CIRCUIT BREAKER OPTIONS
○ 4th Main Line Circuit Breaker
GENERATOR SET
○ Special Testing
○ Battery Box
SG300 | 14.2L | 300 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
251
Item5.
SPEC SHEET
4 of 6
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
General
Make Generac
Cylinder # 6
Type In-line
Displacement - in³ (L) 864.71 (14.2)
Bore: in (mm) 5.31 (135)
Stroke: in (mm) 6.50 (165)
Compression Ratio 9.5:1
Intake Air Method Turbocharged/Aftercooled
Number of Main Bearings 7
Connecting Rods Steel Alloy
Cylinder Head Cast Iron GT250, OHV
Cylinder Liners Ductile Iron
Ignition Electronic
Piston Type Aluminum
Crankshaft Type Ductile Iron
Lifter Type Solid
Intake Valve Material Special Heat-Resistant Steel
Exhaust Valve Material High Temperature Steel Alloy
Hardened Valve Seats High Temperature Steel Alloy
Engine Governing
Governor Electronic
Frequency Regulation (Steady State) ±0.25%
Lubrication System
Oil Pump Gear
Oil Filter Type Full-Flow with Cartridge
Engine Oil Capacity: qt (L) 36.2 (34.3)
Cooling System
Cooling System Type Pressurized Closed Recovery
Fan Type Pusher
Fan Speed (RPM) 1,894
Fan Diameter - in (mm) 34 (864)
Fuel System
Fuel Type Natural Gas
Carburetor Down Draft
Secondary Fuel Regulator Standard
Fuel Shut Off Solenoid Standard
Operating Fuel Pressure- in H2O (kPa) 7 - 11 (1.7 - 2.7) *When designing the external fuel system, assume a 20% safety factor to the upper and lower limit of the specified fuel pressure range to account for site variation and measurement at the generator test port. Refer to Generac document 10000046207, latest rev. for proper gas supply design guidelines. (Contact Factory for Details)
Engine Electrical System
System Voltage 24 VDC
Battery Charger Alternator 58 A
Battery Size See Battery Index 0161970SBY
Battery Voltage (2) - 12 VDC
Ground Polarity Negative (-)
ALTERNATOR SPECIFICATIONS
Standard Model K0300124Y21
Poles 4
Field Type Revolving
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distortion <5% (3-Phase)
Telephone Interference Factor (TIF) <50
Standard Excitation Permanent Magnet
Bearings Sealed Ball
Coupling Direct via Flexible Disc
Prototype Short Circuit Test Yes
Voltage Regulator Type Full Digital
Number of Sensed Phases All
Regulation Accuracy (Steady State) ±0.25%
SG300 | 14.2L | 300 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
252
Item5.
SPEC SHEET
5 of 6
OPERATING DATA
POWER RATINGS - NATURAL GAS
Standby/Demand Response Prime
Three-Phase 120/208 VAC @0.8pf 300kW/375 kVA Amps: 1,042 270 kW/337.5 kVA Amps: 938 Three-Phase 120/240 VAC @0.8pf 300kW/375 kVA Amps: 903 270 kW/337.5 kVA Amps: 813 Three-Phase 277/480 VAC @0.8pf 300kW/375 kVA Amps: 452 270 kW/337.5 kVA Amps: 406 Three-Phase 346/600 VAC @0.8pf 300kW/375 kVA Amps: 361 270 kW/337.5 kVA Amps: 325 MOTOR STARTING CAPABILITIES (skVA)
skVA vs. Voltage Dip
277/480 VAC 30% 208/240 VAC 30%
K0300124Y21 790 K0300124Y21 609
FUEL CONSUMPTION RATES*
Natural Gas – scfh (m³/hr)
Percent Load Standby/Demand Response Prime
25% 1,260 (35.7) 1,200 (34.0)
50% 1,980 (56.1) 1,860 (52.7)
75% 2,700 (76.5) 2,460 (69.7)
100% 3,420 (96.8) 3,120 (88.3)
*1.5X maximum site rated fuel consumption should be used for gas supply design practices.
Refer to Generac 10000046207, latest rev., for more information or contact factory for details.
COOLING
Standby/Demand Response Prime
Air Flow (Fan Air Flow Across Radiator) cfm (m³/min) 15,946 (452) 15,946 (452) Coolant Flow gpm (Lpm) 90 (340.7) 90 (340.7)
Coolant System Capacity gal (L) 15 (54.9) 15 (54.9)
Maximum Operating Ambient Temperature °F (°C) 122 (50) 122 (50) Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD See Bulletin No. 0199270SSD Maximum Additional Radiator Backpressure in H2O (kPa) 0.5 (0.12) 0.5 (0.12)
COMBUSTION AIR REQUIREMENTS
Standby/Demand Response Prime
Flow at rated power cfm - (m³/min) 540 (15.3) 497 (14.1) ENGINE
Standby/Demand
Response
Prime
Rated Engine Speed RPM 1,800 1,800
Horsepower at Rated
kW**
hp 448 403
Piston Speed ft/min (m/
min)
1,950 (594) 1,950 (594)
BMEP psi (kPa) 227 (1,568) 205 (1,411)
** See “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
EXHAUST
Standby/Demand
Response
Prime
Exhaust Flow (Rated
Output) cfm (m³/min) 2,194 (62) 1,958 (55)
Max. Backpressure (Post
Silencer) inHG (kPa) 0.75 (2.54) 0.75 (2.54)
Exhaust Temp (Rated
Output - Post Silencer) °F (°C) 1,415 (768) 1,385 (752) Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with BS5514 and DIN6271 standards.
Standby - See Bulletin 0187500SSB • Demand Response - See Bulletin 10000018250 • Prime - See Bulletin 0187510SSB SG300 | 14.2L | 300 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DEMAND RESPONSE READY
253
Item5.
SPEC SHEET
Generac Power Systems, Inc. | S45 W29290 HWY. 59 | Waukesha, WI 53189 | generac.com ©2024 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
Part No. 10000039053
Rev. E 11/04/2024
6 of 6
SG300 | 14.2L | 300 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
DIMENSIONS AND WEIGHTS* DEMAND RESPONSE READY
OPEN SET (Includes Exhaust Flex)
L x W x H - in (mm) 136.0 (3,454) x 57.1 (1,450) x 67.9 (1,725) Weight - lbs (kg) Minimum Weight: 6,200 (2,812)
Maximum Weight: 6,587 (2,987)
WEATHER PROTECTED ENCLOSURE
L x W x H - in (mm) 174.7 (4,437) x 57.5 (1,461) x 77.8 (1,976) Weight - lbs (kg) Steel Minimum Weight: 7,535 (3,417)
Steel Maximum Weight: 7,919 (3,591)
Aluminum Minimum Weight: 6,978 (3,165)
Aluminum Maximum Weight: 7,359 (3,337)
LEVEL 1 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 200.2 (5,085) x 57.5 (1,461) x 77.8 (1,976) Weight - lbs (kg) Steel Minimum Weight: 7,770 (3,524)
Steel Maximum Weight: 8,273 (3,752)
Aluminum Minimum Weight: 7,176 (3,254)
Aluminum Maximum Weight: 7,625 (3,458)
LEVEL 2 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 180.6 (4,587) x 57.5 (1,461) x 111.3 (2,827) Weight - lbs (kg) Steel Minimum Weight: 8,804 (3,993)
Steel Maximum Weight: 9,188 (4,167)
Aluminum Minimum Weight: 7,423 (3,366)
Aluminum Maximum Weight: 7,870 (3,569)
LEVEL 3 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 207.3 (5,265) x 63.7 (1,618) x 128.9 (3,274) Weight - lbs (kg) Steel Minimum Weight: 10,718 (4,861)
Steel Maximum Weight: 11,080 (5,025)
* All measurements are approximate and for estimation purposes only.
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings 254
Item5.
SG400 | 21.9L | 400 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
1 of 6
DEMAND RESPONSE READY
Powering Ahead
Generac ensures superior quality by designing and
manufacturing most of its generator components, such
as alternators, enclosures, control systems and
communications software. Generac also makes its own
spark-ignited engines, and you’ll find them on every
Generac gaseous-fueled generator. We engineer and
manufacture them from the block up — all at our
facilities throughout Wisconsin. Applying natural gas
and LP-fueled engines to generators requires advanced
engineering expertise to ensure reliability, durability and necessary performance. By designing specifically for
these dry, hotter-burning fuels, the engines last longer and require less maintenance. Building our own
engines also means we control every step of the supply
chain and delivery process, so you benefit from singlesource responsibility.
Plus, Generac Industrial Power’s distribution network
provides all parts and service so you don’t have to deal with third-party suppliers. It all leads to a positive
owner experience and higher confidence level. Generac
spark-ignited engines give you more options in
commercial and industrial generator applications as
well as extended run time from utility-supplied natural gas.
Codes and Standards
Not all codes and standards apply to all configurations. Contact factory for details.
UL2200, UL6200, UL1236, UL489
CSA C22.2, B149
BS5514 and DIN 6271
SAE J1349
NFPA 37, 70, 99, 110
NEC700, 701, 702, 708
ISO 3046, 7637, 8528, 9001
NEMA ICS10, MG1, 250, ICS6, AB1
ANSI C62.41
IBC 2009, CBC 2010, IBC 2012,
ASCE 7-05, ASCE 7-10,
ICC-ES AC-156 (2012)
TM
®
®
Image used for illustration purposes only
Standby Power Rating
400 kW, 500 kVA, 60 Hz
Demand Response Rating
400 kW, 500 kVA, 60 Hz
Prime Power Rating
360 kW, 450 kVA, 60 Hz
*Assembled in the USA using
domestic and foreign parts
255
Item5.
SG400 | 21.9L | 400 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
2 of 6
DEMAND RESPONSE READY
CONTROL SYSTEM
Power Zone® Pro Sync Controller
Program Functions
• NFPA 110 Level 1 Compliant
• Engine Protective Functions
• Alternator Protective Functions
• Digital Engine Governor Control
• Digital Voltage Regulator
• Multiple Programmable Inputs and Outputs
• Remote Display Capability
• Remote Communication via Modbus® RTU,
Modbus TCP/IP, and Ethernet 10/100
• Alarm and Event Logging with Real Time Stamping
• Expandable Analog and Digital Inputs and Outputs
• Remote Wireless Software Update Capable
• Wi-Fi, Bluetooth, BMS and Remote Telemetry
• Built-In Programmable Logic Eliminates the Need for
External Controllers Under Most Conditions
• Ethernet Based Communications
Between Generators
• Programmable I/O Channel Properties
• Built-In Diagnostics
Protections
• Low Oil Pressure
• Low Coolant Level
• High/Low Coolant Temperature
• Sensor Failure
• Oil Temperature
• Over/Under Speed
• Over/Under Voltage
• Over/Under Frequency
• Over/Under Current
• Over Load
• High/Low Battery Voltage
• Battery Charger Current
• Phase to Phase and Phase to Neutral Short Circuits
(I2T Algorithm)
7 Inch Color Touch Screen Display
• Resistive Color Touch Screen
• Sunlight Readable (1400 NITS)
• Easily Identifiable Icons
• Multi-Lingual
• On Screen Editable Parameters
• Key Function Monitoring
• Three Phase Voltage, Amperage, kW, kVA,
and kVAR
• Selectable Line to Line or Line to
Neutral Measurements
• Frequency
• Engine Speed
• Engine Coolant Temperature
• Engine Oil Pressure
• Engine Oil Temperature
• Battery Voltage
• Hourmeter
• Warning and Alarm Indication
• Diagnostics
• Maintenance Events/Information
ENGINE SYSTEM
• Oil Drain Extension
• Engine Coolant Heater
• Air Cleaner
• Stainless Steel Flexible Exhaust Connection
• Factory Filled Oil and Coolant
• Radiator Duct Adapter (Open Set Only)
• Critical Silencer
Fuel System
• NPT Fuel Connection on Frame
• Primary and Secondary Fuel Shutoff
Cooling System
• Closed Coolant Recovery System
• UV/Ozone Resistant Hoses
• Factory-Installed Radiator
• 50/50 Ethylene Glycol Antifreeze
• Radiator Drain Extension
Electrical System
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ALTERNATOR SYSTEM
• UL2200 GENprotect™
• Class H Insulation Material
• 2/3 Pitch
• Skewed Stator
• Permanent Magnet Excitation
• Sealed Bearing
• Amortisseur Winding
• Full Load Capacity Alternator
GENERATOR SET
• Internal Genset Vibration Isolation
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Wrapped Exhaust Piping
• Standard Factory Testing
• 2 Year Limited Warranty (Standby and Demand
Response Rated Units)
• 1 Year Limited Warranty (Prime Rated Units)
• Silencer Mounted in the Discharge Hood
(Enclosed Units Only)
ENCLOSURE (If Selected)
• Rust-Proof Fasteners with Nylon Washers to
Protect Finish
• High Performance Sound-Absorbing Material
(Sound Attenuated Enclosures)
• Gasketed Doors
• Upward Facing Discharge Hoods (Radiator
and Exhaust)
• Stainless Steel Lift Off Door Hinges
• Stainless Steel Lockable Handles
• RhinoCoat™ - Textured Polyester Powder Coat Paint
STANDARD FEATURES
256
Item5.
SG400 | 21.9L | 400 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
3 of 6
CONFIGURABLE OPTIONS DEMAND RESPONSE READY
ENGINE SYSTEM
○ Baseframe Cover/Rodent Guard
○ Oil Heater
○ Air Filter Restriction Indicator
○ Radiator Stone Guard (Open Set Only)
○ Level 1 Fan and Belt Guards (Enclosed Units Only)
FUEL SYSTEM
○ NPT Flexible Fuel Line
ELECTRICAL SYSTEM
○ 10A UL Listed Battery Charger
○ Battery Warmer
ALTERNATOR SYSTEM
○ Alternator Upsizing
○ Anti-Condensation Heater
○ Tropical Coating
CIRCUIT BREAKER OPTIONS
○ Main Line Circuit Breaker
○ 2nd Main Line Circuit Breaker
○ Shunt Trip and Auxiliary Contact
○ Electronic Trip Breakers
GENERATOR SET
○ Demand Response Rating
○ Extended Factory Testing (3-Phase Only)
○ 12 Position Load Center
ENCLOSURE
○ Weather Protected Enclosure
○ Level 1 Sound Attenuated
○ Level 2 Sound Attenuated
○ Level 2 Sound Attenuated with Motorized Dampers
○ Level 3 Sound Attenuated (Steel Only)
○ Steel Enclosure
○ Aluminum Enclosure
○ Damper Alarm (Motorized Dampers Only)
○ Up to 200 MPH Wind Load Rating (Contact Factory
for Availability)
○ AC/DC Enclosure Lighting Kit
○ Enclosure Heaters (Motorized Dampers Only)
○ Door Open Alarm Switch
CONTROL SYSTEM
○ NFPA 110 Compliant 21-Light Remote Annunciator
○ Remote Relay Assembly (8 or 16)
○ Oil Temperature Sender with Indication Alarm
○ Remote E-Stop (Break Glass-Type, Surface Mount)
○ Remote E-Stop (Red Mushroom-Type,
Surface Mount)
○ Remote E-Stop (Red Mushroom-Type, Flush Mount)
○ 10A Engine Run Relay
○ Ground Fault Annunciator
○ 100 dB Alarm Horn
○ 120V GFCI and 240V Outlets
WARRANTY (Standby Gensets Only)
○ 2 Year Extended Limited Warranty
○ 5 Year Limited Warranty
○ 5 Year Extended Limited Warranty
○ 7 Year Extended Limited Warranty
○ 10 Year Extended Limited Warranty
ENGINEERED OPTIONS
ENGINE SYSTEM
○ Coolant Heater Ball Valves
○ Fluid Containment Pan
ALTERNATOR SYSTEM
○ 3rd Breaker System
CONTROL SYSTEM
○ Battery Disconnect Switch
GENERATOR SET
○ Special Testing
○ Battery Box
257
Item5.
SG400 | 21.9L | 400 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
4 of 6
DEMAND RESPONSE READY
General
Make Generac
Cylinder # 12
Type V12
Displacement - in3
(L) 1,336.4 (21.9)
Bore - in (mm) 5.03 (128)
Stroke - in (mm) 5.6 (142)
Compression Ratio 10.0:1
Intake Air Method Turbocharged/Aftercooled
Number of Main Bearings 7
Connecting Rods Steel Alloy
Cylinder Head Cast Iron
Cylinder Liners Cast Steel Alloy
Ignition Electronic
Piston Type Cast Aluminum Alloy
Crankshaft Type Steel
Lifter Type Solid
Intake Valve Material High Temp Steel Alloy
Exhaust Valve Material High Temp Steel Alloy
Hardened Valve Seats Proprietary Alloy
Engine Governing
Governor Electronic
Frequency Regulation (Steady State) ±0.25%
Lubrication System
Oil Pump Type Gear
Oil Filter Type Full-Flow Spin on Cartridge
Crankcase Capacity - qt (L) 31.7 (30)
Cooling System
Cooling System Type Pressurized Closed Recovery
Fan Type Pusher
Fan Speed - RPM 1,404
Fan Diameter - in (mm) 44 (1,117.6)
Fuel System
Fuel Type Natural Gas
Carburetor Down Draft
Secondary Fuel Regulator Standard
Fuel Shut Off Solenoid Standard
Operating Fuel Pressure - in H2O (kPa) 11 - 14 (2.7 - 3.5) Optional Operating Fuel Pressure - in H2O (kPa) 7 - 11 (1.7 - 2.7) Engine Electrical System
System Voltage 24 VDC
Battery Charger Alternator 57 A
Battery Size See Battery Index 0161970SBY
Battery Voltage (2) - 12 VDC
Ground Polarity Negative
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
ALTERNATOR SPECIFICATIONS
Standard Model K0400124Y21
Poles 4
Field Type Revolving
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distortion <5% (3-Phase)
Telephone Interference Factor (TIF) <52
Standard Excitation Permanent Magnet
Bearings Sealed Ball
Coupling Direct via Flexible Disc
Prototype Short Circuit Test Yes
Voltage Regulator Type Full Digital
Number of Sensed Phases All
Regulation Accuracy (Steady State) ±0.25%
258
Item5.
SG400 | 21.9L | 400 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
5 of 6
DEMAND RESPONSE READY
** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, and DIN6271 standards.
Standby - See Bulletin 0187500SSB
Demand Response - See Bulletin 10000018250
Prime - See Bulletin 0187510SSB
POWER RATINGS - NATURAL GAS
Standby/Demand Response Prime
Three-Phase 120/208 VAC @0.8pf 400 kW/500 kVA Amps: 1,390 360 kW/450 kVA Amps: 1,251 Three-Phase 120/240 VAC @0.8pf 400 kW/500 kVA Amps: 1,204 360 kW/450 kVA Amps: 1,084 Three-Phase 277/480 VAC @0.8pf 400 kW/500 kVA Amps: 602 360 kW/450 kVA Amps: 542 Three-Phase 346/600 VAC @0.8pf 400 kW/500 kVA Amps: 482 360 kW/450 kVA Amps: 434 MOTOR STARTING CAPABILITIES (skVA)
skVA vs. Voltage Dip
277/480_3PH 30% 208/240 VAC 30%
K0400124Y21 953 K0500124Y23 730
K0500124Y23 1,020 K0600124Y23 1,120
K0600124Y23 1,560
FUEL CONSUMPTION RATES*
Natural Gas – scfh (m3/hr)
Percent Load Standby/Demand Response Prime
25% 1,680 (47.6) 1,620 (45.9)
50% 2,640 (74.8) 2,460 (69.7)
75% 3,600 (101.9) 3,300 (93.4)
100% 4,620 (130.8) 4,200 (118.9)
* Fuel supply installation must accommodate fuel consumption rates at 100% load.
COOLING
Standby/Demand Response Prime
Air Flow (Fan Air Flow Across Radiator) scfm (m3/min) 28,004 (793) 28,004 (793) Coolant Flow gpm (Lpm) 211 (798.6) 211 (798.6)
Coolant System Capacity gal (L) 15.5 (58.7) 15.5 (58.7) Max. Operating Ambient Temperature °F (°C) 122 (50) 122 (50) Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD Maximum Radiator Backpressure in H2O (kPa) 0.5 (0.12) 0.5 (0.12)
COMBUSTION AIR REQUIREMENTS
Standby/Demand Response Prime
Flow at Rated Power - scfm (m3
/min) 731 (20.7) 666 (18.9)
ENGINE EXHAUST
Standby/Demand
Response Prime Standby/Demand Response Prime
Rated Engine Speed RPM 1,800 1,800 Exhaust Flow (Rated Output) scfm (m3/min) 2,378 (67.3) 2,142 (60.7) Horsepower at Rated kW** hp 589 530 Max. Backpressure (Post Silencer) inHg (kPa) 0.75 (2.54) 0.75 (2.54) Piston Speed ft/min (m/min) 1,680 (512) 1,680 (512) Exhaust Temp (Rated Output - Post Silencer) °F (°C) 1,297 (702.8) 1,277 (691.7) BMEP psi (kPa) 194 (1,338) 175 (1,204)
OPERATING DATA
259
Item5.
SG400 | 21.9L | 400 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
6 of 6
DEMAND RESPONSE READY
YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please contact a Generac Power Systems Industrial Dealer for detailed installation drawings. * All measurements are approximate and for estimation purposes only.
Part No. 10000035560
Rev. B 11/15/19
Generac Power Systems, Inc. | P.O. Box 8 | Waukesha, WI 53189 P: (262) 544-4811 ©2019 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice.
DIMENSIONS AND WEIGHTS*
OPEN SET (Includes Exhaust Flex)
L x W x H - in (mm) 154.4 (3,922) x 71.0 (1,803) x 66.5 (1,689) Weight - lbs (kg) 7,286 - 8,650 (3,304 - 3,923)
WEATHER PROTECTED ENCLOSURE
L x W x H - in (mm) 207.4 (5,268) x 71.0 (1,803) x 80.0 (2,032) Weight - lbs (kg) Steel: 9,490 - 10,840 (4,304 - 4,916) Aluminum: 8,404 - 9,753 (3,811 - 4,423)
LEVEL 1 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 247.5 (6,287) x 71.0 (1,803) x 80.0 (2,032) Weight - lbs (kg) Steel: 10,498 - 11,847 (4,761 - 5,373) Aluminum: 8,818 - 10,185 (3,999 - 4,619)
LEVEL 2 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 207.4 (5,268) x 71.0 (1,803) x 114.1 (2,898) Weight - lbs (kg) Steel: 10,836 - 12,185 (4,914 - 5,526) Aluminum: 8,963 - 10,330 (4,065 - 4,685)
LEVEL 3 SOUND ATTENUATED ENCLOSURE
L x W x H - in (mm) 232.0 (5,893) x 76.9 (1,953) x 129.2 (3,282) Weight - lbs (kg) 13,224 - 14,285 (5,997 - 6,478)
L
H
W
L
H
W
L
H
W
L
H
W
260
Item5.
SG1000 | 49.0L | 1,000 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
1 of 6
DEMAND RESPONSE READY
Standby Power Rating
1,000 kW, 1,250 kVA, 60 Hz
Demand Response Rating
1,000 kW, 1,250 kVA, 60 Hz
Powering Ahead
Generac ensures superior quality by designing and manufacturing most of its generator components, such as alternators, enclosures, control systems and communications software. Generac also makes its own spark-ignited engines, and you’ll find them on every Generac gaseous-fueled generator. We engineer and manufacture them from the block up — all at our facilities throughout Wisconsin.
Applying natural gas and LP-fueled engines to generators requires advanced engineering expertise to ensure reliability, durability and necessary performance. By designing specifically for these dry, hotter-burning fuels, the engines last longer and require less maintenance. Building our own engines also means we control every step of the supply chain and delivery process, so you benefit from single-source responsibility.
Plus, Generac Industrial Power’s distribution network provides all parts and service so you don’t have to deal with third-party suppliers. It all leads to a positive owner experience and higher confidence level. Generac spark-ignited engines give you more options in commercial and industrial generator applications as well as extended run time from utility-supplied natural gas.
Codes and Standards
Not all codes and standards apply to all configurations. Contact factory for details.
UL2200, UL6200, UL1236, UL489
CSA C22.2, B149
BS5514 and DIN 6271
SAE J1349
NFPA 37, 70, 99, 110
NEC700, 701, 702, 708
ISO 3046, 7637, 8528, 9001
NEMA ICS10, MG1, 250, ICS6, AB1
ANSI C62.41
TM
®
®
Image used for illustration purposes only
261
Item5.
SG1000 | 49.0L | 1,000 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
2 of 6
DEMAND RESPONSE READY
CONTROL SYSTEM
Power Zone® Pro Sync Controller
• NFPA 110 Level 1 Compliant
• Engine Protective Functions
• Alternator Protective Functions
• Digital Engine Governor Control
• Digital Voltage Regulator
• Multiple Programmable Inputs and Outputs
• Remote Display Capability
• Remote Communication via Modbus® RTU,
Modbus TCP/IP, and Ethernet 10/100
• Alarm and Event Logging with Real
Time Stamping
• Expandable Analog and Digital Inputs and Outputs
• Remote Wireless Software Update Capable
• BMS and Remote Telemetry
• Built-In Programmable Logic Eliminates the Need for
External Controllers Under Most Conditions
• Ethernet Based Communications
Between Generators
• Programmable I/O Channel Properties
• Built-In Diagnostics
• Arc Flash Maintenance Mode (When
Properly Equipped)
Alarms and Warnings
• Low Oil Pressure
• Low Coolant Level
• High/Low Coolant Temperature
• Sensor Failure
• Oil Temperature
• Over/Under Speed
• Over/Under Voltage
• Over/Under Frequency
• Over/Under Current
• Over Load
• High/Low Battery Voltage
• Battery Charger Current
• Phase to Phase and Phase to Neutral Short Circuits
(I2
T Algorithm)
7 Inch Color Touch Screen Display
• Resistive Color Touch Screen
• Sunlight Readable (1400 NITS)
• Easily Identifiable Icons
• Multi-Lingual
• On Screen Editable Parameters
• Key Function Monitoring
• Three Phase Voltage, Amperage, kW, kVA,
and kVAr
• Selectable Line to Line or Line to
Neutral Measurements
• Frequency
• Engine Speed
• Engine Coolant Temperature
• Engine Oil Pressure
• Engine Oil Temperature
• Battery Voltage
• Hourmeter
• Warning and Alarm Indication
• Diagnostics
• Maintenance Events/Information
ENGINE SYSTEM
• Oil Drain Extension
• Heavy Duty Air Cleaner
• Level 1 Fan and Belt Guards (Open Set Only)
• Stainless Steel Flexible Exhaust Connection
• Radiator Duct Adapter (Open Set Only)
• Critical Silencer/Catalyst
• Coolant Heater Ball Valves
• Factory Filled Oil and Coolant
• Oil Temperature Sender with Indication Alarm
FUEL SYSTEM
• Primary and Secondary Fuel Shutoff
COOLING SYSTEM
• Closed Coolant Recovery System
• Factory-Installed Radiator
• Radiator Drain Extension
• 50/50 Ethylene Glycol Antifreeze
ELECTRICAL SYSTEM
• Battery Charging Alternator
• Battery Cables
• Battery Tray
• Rubber-Booted Engine Electrical Connections
• Solenoid Activated Starter Motor
ALTERNATOR SYSTEM
• UL2200 GENprotect™
• Class H Insulation Material
• 2/3 Pitch
• Skewed Stator
• Permanent Magnet Excitation
• Sealed Bearings
• Amortisseur Winding
• Low Temperature Rise (<120 °C)
GENERATOR SET
• Spring Isolators Under Frame
• Separation of Circuits - High/Low Voltage
• Separation of Circuits - Multiple Breakers
• Standard Factory Testing
• 2 Year Limited Warranty (Standby or Demand
Response Rated Units)
• Ready to Accept Load in <10 Seconds
ENCLOSURE (If Selected)
• Structural Steel Sub-Base
• Sub-Base Lifting Eyes
• Enamel Finish
• Zinc Plated Fasteners
• Zinc Plated Cast Aluminum Keylock Door Handles
• Heavy Duty Stainless Steel Hinges
• Modular Construction
• Rhino Coat™ - Textured Polyester Powder
Coat Paint
STANDARD FEATURES
262
Item5.
SG1000 | 49.0L | 1,000 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
3 of 6
CONFIGURABLE OPTIONS DEMAND RESPONSE READY
ENGINE SYSTEM
○ Engine Coolant Heater
○ Oil Heater
○ Level 1 Fan and Belt Guards (Enclosed Units Only)
○ Two Stage Air Cleaner
○ Air Filter Restriction Indicator
○ Radiator Stone Guard (Open Set Only)
○ Baseframe Cover/Rodent Guard
ELECTRICAL SYSTEM
○ 20A UL Listed Battery Charger
○ Battery Warmer
FUEL SYSTEM
○ NPT Flexible Fuel Line
ALTERNATOR SYSTEM
○ Alternator Upsizing
○ Anti-Condensation Heater
CIRCUIT BREAKER OPTIONS
○ Up to 4 Main Line Circuit Breaker Selection
○ Shunt Trip and Auxiliary Contact
○ Electronic Trip Breaker
GENERATOR SET
○ Spring Vibration Isolator
○ Extended Factory Testing (3-Phase Only)
○ 24 Position Load Center
ENCLOSURE
○ Level 0 Sound Attenuated
○ Level 1 Sound Attenuated
○ Level 2 Sound Attenuated
○ Level 2 Sound Attenuated with Motorized Dampers
○ Steel Enclosure
○ Aluminum Enclosure
○ AC/DC Enclosure Lighting Kit
○ Enclosure Heater (With Motorized Dampers Only)
○ Up to 180 MPH Wind Load Rating (Contact Factory
for Availability)
CONTROL SYSTEM
○ NFPA 110 Level 1 Compliant 21-Light Remote
Annunciator
○ Remote Output Relays (8 or 16)
○ Remote E-Stop (Break Glass-Type, Surface Mount)
○ Remote E-Stop (Red Mushroom-Type,
Surface Mount)
○ Remote E-Stop (Red Mushroom-Type, Flush Mount)
○ 10A Engine Run Relay
○ Ground Fault Annunciator
○ Damper Alarm Contacts (With Motorized
Dampers Only)
○ 100 dB Alarm Horn
○ 120V GFCI and 240V Outlets
WARRANTY (Standby Gensets Only)
○ 2 Year Extended Limited Warranty
○ 5 Year Limited Warranty
○ 5 Year Extended Limited Warranty
○ 7 Year Extended Limited Warranty
○ 10 Year Extended Limited Warranty
ENGINEERED OPTIONS
CONTROL SYSTEM
○ Additional Spare Inputs/Outputs
○ Battery Disconnect Switch
ALTERNATOR SYSTEM
○ Unit Mounted Load Banks
○ Medium Voltage Alternators
ENCLOSURE
○ Door Open Alarm Horn
GENERATOR SET
○ Special Testing
○ Battery Boxes
263
Item5.
SG1000 | 49.0L | 1,000 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
4 of 6
DEMAND RESPONSE READY
General
Make Generac
Cylinder # 12
Type V
Displacement - in3 (L) 2,992 (49.03)
Bore - in (mm) 6.69 (170)
Stroke - in (mm) 7.09 (180)
Compression Ratio 10.0:1
Intake Air Method Turbocharged/Aftercooled
Number of Main Bearings 7
Number of Connecting Rods 12
Cylinder Head 4 Valve
Cylinder Liners Yes
Ignition MotorTech
Piston Type Cast Aluminum Alloy
Crankshaft Type Chromium Molybdenum Steel SCM440H
Lifter Type Solid
Intake Valve Material Proprietary Alloy
Exhaust Valve Material Proprietary Alloy
Hardened Valve Seats Proprietary Alloy
Engine Governing
Governor Electronic
Frequency Regulation (Steady State) ±0.25%
Lubrication System
Oil Pump Type Gear Driven
Oil Filter Type Full Flow Spin-On Cartridge
Crankcase Capacity with Filter - qt (L) 285 (270)
Cooling System
Cooling System Type Forced Circulation by Centrifugal Pump Fan Type Pusher
Fan Speed - RPM 1,025
Fan Diameter - in (mm) 76 (1,930)
Fuel System
Fuel Type Natural Gas
Carburetor Variable Venturi
Secondary Fuel Regulator Standard
Fuel Shut Off Solenoid Standard
Operating Fuel Pressure - in H2O (kPa) 14 - 28 (3.5 - 7.0) Engine Electrical System
System Voltage 24 VDC
Battery Charger Alternator Standard
Battery Size See Battery Index 0161970SBY
Battery Voltage (4) - 12 VDC
Ground Polarity Negative
APPLICATION AND ENGINEERING DATA
ENGINE SPECIFICATIONS
ALTERNATOR SPECIFICATIONS
Standard Model K1248064N22
Poles 4
Field Type Rotating
Insulation Class - Rotor H
Insulation Class - Stator H
Total Harmonic Distortion <5%
Telephone Interference Factor (TIF) <50
Standard Excitation Permanent Magnet
Bearings Single
Coupling Flexible Plates
Prototype Short Circuit Test Yes
Voltage Regulator Type Full Digital
Number of Sensed Phases All
Regulation Accuracy (Steady State) ±0.5%
264
Item5.
SG1000 | 49.0L | 1,000 kW
INDUSTRIAL SPARK-IGNITED GENERATOR SET
EPA Certified Stationary Emergency and Non-Emergency
SPEC SHEET
5 of 6
DEMAND RESPONSE READY
** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions.
Please contact a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528, and DIN6271 standards.
Standby - See Bulletin 0187500SSB
Demand Response - See Bulletin 10000018250
POWER RATINGS - NATURAL GAS
Standby/Demand Response
Three-Phase 277/480 VAC @0.8pf 1,000 kW/1,250 kVA Amps: 1,505 Three-Phase 346/600 VAC @0.8pf 1,000 kW/1,250 kVA Amps: 1,204 MOTOR STARTING CAPABILITIES (skVA)
skVA vs. Voltage Dip
277/480 VAC 30%
K1248064N22 3,300
K1344064N22 4,000
K1500064N22 4,500
FUEL CONSUMPTION RATES*
Natural Gas – scfh (m3/hr) at Standard Conditions 68 °F (20 °C), 14.7 psi (101 kPa) Percent Load Standby/Demand Response
25% 3,418 (96.8)
50% 6,021 (170.5)
75% 8,655 (245.1)
100% 11,243 (318.4)
* Fuel supply installation must accommodate fuel consumption rates at 100% load.
COOLING
Standby/Demand Response
Air Flow (Fan Air Flow Across Radiator) - Open Set cfm (m3 /min) 57,846 (1,638)
Coolant Flow gpm (Lpm) 489 (1,850)
Coolant System Capacity gal (L) 80 (303)
Maximum Operating Ambient Temperature °F (°C) 122 (50)
Maximum Operating Ambient Temperature (Before Derate) See Bulletin No. 0199270SSD Maximum Additional Radiator Backpressure in H2O (kPa) 0.5 (0.12)
COMBUSTION AIR REQUIREMENTS
Standby/Demand Response
Flow at Rated Power - cfm (m3
/min) 2,205 (62.4)
ENGINE EXHAUST
Standby/Demand Response Standby/Demand Response
Rated Engine Speed RPM 1,800 Exhaust Flow (Rated Output) cfm (m3 /min) 8,500 (241)
Horsepower at Rated kW** hp 1,467 Maximum Allowable Exhaust Backpressure (Post Silencer) inHg (kPa) 0.73 (2.49)
Piston Speed ft/min (m/
min) 2,126 (648) Exhaust Temperature (Rated Output) °F (°C) 1,458 (792) BMEP psi (kPa) 216 (1,488)