HR-E LCD

HR-E LCD
The HR-E LCD is a permanently sealed, electronic LCD absolute encoder which produces an industry standard ASCII encoded output .

Measurement Resolution
Recordall
Disc Series Size (in.) 9-Digit Encoder
Gallons Cubic Feet Cubic Meters
LP 5/8, 5/8 x 3/4 0 .01 0 .001 0 .0001
M25 5/8, 5/8 x 3/4 0 .01 0 .001 0 .0001
M35 3/4 0 .01 0 .001 0 .0001
M40 1 0 .01 0 .001 0 .0001
M55 1 0 .01 0 .001 0 .0001
M70 1 0 .01 0 .001 0 .0001
M120 1-1/2 0 .1 0 .01 0 .001
M170 2 0 .1 0 .01 0 .001
Recordall
Turbo Series Size (in.) 9-Digit Encoder
Gallons Cubic Feet Cubic Meters
T160 1-1/2 0 .1 0 .01 0 .001
T200 2 0 .1 0 .01 0 .001
T450 3 0 .1 0 .01 0 .001
T1000 4 0 .1 0 .01 0 .001
T2000 6 1 0 .1 0 .01
T3500 8 1 0 .1 0 .01
T5500 10 1 0 .1 0 .01
T6200 12 10 1 0 .01
T6600 16 10 1 0 .01
T10000 20 10 1 0 .01
Recordall Compound
Series Size (in.) 9-Digit Encoder
Gallons Cubic Feet Cubic Meters
High Side T200 2 0 .1 0 .01 0 .001
Low Side M25 2 0 .01 0 .001 0 .0001
High Side T450 3 0 .1 0 .01 0 .001
Low Side M25 3 0 .01 0 .001 0 .0001
High Side T1000 4 0 .1 0 .01 0 .001
Low side M35 4 0 .01 0 .001 0 .0001
High Side T2000 6 1 0 .1 0 .01
Low Side M35 6 0 .01 0 .001 0 .0001
High Side T3500 8 1 0 .1 0 .01
Low side M120 8 0 .1 0 .01 0 .001
Endpoint Reading Resolution

MPORTANTI
The standard electronic encoder output resolution of the HR-E LCD encoder is 9 digits. Though the encoder output is 9-digit resolution, the reading resolution sent to the reading software is dependent on the endpoint that the encoder is connected to.

Readings reported from the endpoints are the left-most significant digits of the encoder reading.

Endpoint Technology Reading Resolution Reported to Reading Software ORION Cellular, ORION Mobile M 9-digit reading, plus the extended message capability ORION ME/ORION SE 8-digit reading, plus the extended message capability ORION Classic (CE) 7-digit reading
GALAXY 6-digit reading
See the application brief, HR-E LCD Encoder Test Circle Codes, available at www.badgermeter.com, for the appropriate test circle code/reading resolutions for the HR-E LCD encoder with ORION or GALAXY endpoints . Other output options are available for certain applications .

Page 7 ends

HR-E LCD
Status Indicators
Status indicators are sent as part of the encoder message to AMR/AMI systems that are capable of receiving an extended message, such as ORION Cellular, ORION Mobile M, ORION SE and ORION ME endpoints . The details can also be read through an IR interface .

Status indicators appear in the display as symbols that illuminate when the condition is active and dim when the condition is eliminated .

All HR-E LCD encoders are delivered in storage mode so that a meter alarm is not triggered . During storage mode, the meter model displays on the encoder . As water begins to flow through the meter, the encoder switches from storage mode to normal operation upon sensing two (2) revolutions of the meter magnet .

The following chart indicates the HR-E LCD encoder conditions when connected to an appropriate Badger Meter ORION endpoint . The chart does not apply to ORION Classic (CE) or GALAXY endpoints, or HR-E LCD encoders programmed to a resolution lower than a 9-digit output . The HR-E LCD encoder displays the information, but the extra information is not reported through the endpoints .

Status Indicator Icon Status Description HR-E LCD Display HR-E LCD with ORION Cellular,
ORION Mobile M or ORION SE*
and ORION ME* Endpoints
*Firmware version 1 .8 or higher required
Meter functioning
correctly

Encoder operating correctly .

Continuous display on encoder as
long as no other status indicators
are triggered .

Indicator status not sent to
the endpoint .

Encoder alarm
Several potential conditions
may exist, including:

Encoder removal
Temperature limit exceeded
(34…140° F)
Magnetic tamper
Encoder alarm remains active for
35 days . The alarm automatically
clears after 35 days if any of the 3
conditions has not recurred .

Encoder alarm sent to the endpoint
until resolved .

Reverse flow
Encoder detects reverse flow .

Reverse flow alarm remains active
for 35 days . The alarm automatically
clears after 35 days if reverse flow
condition has not recurred .

Encoder detects reverse flow
and sends alarm message to
the endpoint until resolved .

Suspected leak
Encoder detects 24 hours
without one 15-minute
interval of no flow .

The alarm clears automatically
when a 15-minute no-flow
interval occurs .

Encoder detects suspected leak
and sends alarm message to
the endpoint .

If condition clears before
message is sent to the endpoint,
it is not reported .
30 day no usage
No measured flow in past
30 days .

The alarm is automatically cleared
once flow occurs .

Encoder detects 30 days no usage
and sends alarm to the endpoint .

If condition clears before
message is sent to the endpoint,
it is not reported .

End of life
battery indicator

Indicated battery life based on
pre-calculated consumption .

Alarm activated at 19 years and
does not clear .

Encoder sends alarm to the endpoint
indefinitely . Permanent alarm after
19 years .

Page 8 ends

HR-E LCD 4-20
HR-E LCD 4-20
The HR-E LCD 4-20 is a permanently sealed, electronic LCD absolute encoder which produces an industry standard ASCII encoded output as well as a 4-20 mA DC output signal through a dual output wire design .

Measurement Resolution
Standard encoded output is 9 digits . The 4-20 signal from the encoder is proportional to the flow of fluid passing through the meter . Power for the 4-20 output signal device can be obtained from a 9…50V DC control loop . The default 20 mA setting of the signal is defined in the resolution chart .

Recordall Disc Series Size (in.) Encoder Output Analog Output 9-dial (gal) 9-dial (ft3) 9-dial (m3) 20 mA Set point (gpm) LP 5/8, 5/8 x 3/4 0 .01 0 .001 0 .0001 20
M25 5/8, 5/8 x 3/4 0 .01 0 .001 0 .0001 25
M35 3/4 0 .01 0 .001 0 .0001 35
M40 1 0 .01 0 .001 0 .0001 40
M55 1 0 .01 0 .001 0 .0001 55
M70 1 0 .01 0 .001 0 .0001 70
M120 1-1/2 0 .1 0 .01 0 .001 120
M170 2 0 .1 0 .01 0 .001 170
Recordall
Turbo Series Size (in.) Encoder Output Analog Output
9-dial (gal) 9-dial (ft3) 9-dial (m3) 20 mA Set point (gpm) T160 1-1/2 0 .1 0 .01 0 .001 200
T200 2 0 .1 0 .01 0 .001 310
T450 3 0 .1 0 .01 0 .001 550
T1000 4 0 .1 0 .01 0 .001 1250
T2000 6 1 0 .1 0 .01 2500
T3500 8 1 0 .1 0 .01 4500
T5500 10 1 0 .1 0 .01 7000
T6200 12 10 1 0 .01 8800
T6600 16 10 1 0 .01 13200
T10000 20 10 1 0 .01 19800
Recordall Compound
Series Size (in.) Encoder Output Analog Output
9-dial (gal) 9-dial (ft3) 9-dial (m3) 20 mA Set point (gpm) High Side T200 2 0 .1 0 .01 0 .001 200
Low Side M25 2 0 .01 0 .001 0 .0001 25
High Side T450 3 0 .1 0 .01 0 .001 450
Low Side M25 3 0 .01 0 .001 0 .0001 25
High Side T1000 4 0 .1 0 .01 0 .001 1000
Low side M35 4 0 .01 0 .001 0 .0001 35
High Side T2000 6 1 0 .1 0 .01 2000
Low Side M35 6 0 .01 0 .001 0 .0001 35
High Side T3500 8 1 0 .1 0 .01 —
Low side M120 8 0 .1 0 .01 0 .001 —

Page 9 ends

HR-E LCD 4-20
Analog Output
• The input pulses generated within the transmitter assembly are converted to a standard 4-20 mA control signal . • This signal is proportional to the flow of fluid passing through the flow meter . • Power for the device can be obtained from a 9…50V DC control loop . • The default 20mA setting of the signal is defined in the registration section .

Endpoint Reading Resolution

MPORTANTI
The standard electronic encoder output resolution of the HR-E LCD 4-20 encoder is 9 digits. Though the encoder output is 9-digit resolution, the reading resolution sent to the reading software is dependent on the endpoint that the encoder is connected to.

Readings reported from the endpoints are the left-most significant digits of the encoder reading.

Endpoint Technology Reading Resolution Reported to Reading Software ORION Cellular, ORION Mobile M 9-digit reading, plus the extended message capability ORION ME/ORION SE 8-digit reading, plus the extended message capability ORION Classic (CE) 7-digit reading
See the application brief, HR-E LCD Encoder Test Circle Codes, available at www.badgermeter.com, for the appropriate test circle code/reading resolutions for the encoder with ORION endpoints . Other output options are available for certain applications .

Page 10 ends

HR-E LCD 4-20
Status Indicators
Status indicators are sent as part of the encoder message to AMR/AMI systems that are capable of receiving an extended message, such as ORION Cellular, ORION Mobile M, ORION SE and ORION ME endpoints . The details can also be read through an IR interface .

Status indicators appear in the display as symbols that illuminate when the condition is active and dim when the condition is eliminated .

All HR-E LCD 4-20 encoders are delivered in storage mode so that a meter alarm is not triggered . During storage mode, the meter model displays on the encoder . As water begins to flow through the meter, the encoder switches from storage mode to normal operation upon sensing two (2) revolutions of the meter magnet .

The following chart indicates the HR-E LCD 4-20 encoder conditions when connected to an appropriate Badger Meter ORION endpoint . The chart does not apply to ORION Classic (CE) or GALAXY endpoints, or HR-E LCD 4-20 encoders programmed to a resolution lower than a 9-digit output . The HR-E LCD 4-20 encoder displays the information, but the extra information is not reported through the endpoints .

Status Indicator Icon Status Description HR-E LCD 4-20 Display HR-E LCD 4-20 with ORION
Cellular, ORION Mobile M or
ORION SE* and ORION ME*
Endpoints
*Firmware version 1 .8 or higher required
Meter functioning
correctly

Encoder operating correctly .

Continuous display on encoder
as long as no other status
indicators are triggered .

Indicator status not sent to
the endpoint .

Encoder alarm
Several potential conditions
may exist, including:

Encoder removal
Temperature limit exceeded
(34…140° F)
Magnetic tamper
Encoder alarm remains active for
35 days . The alarm automatically
clears after 35 days if any of the 3
conditions has not recurred .

Encoder alarm sent to the endpoint
until resolved .

Reverse flow
Encoder detects reverse flow .

Reverse flow alarm remains
active for 35 days . The alarm
automatically clears after 35
days if reverse flow condition has
not recurred .

Encoder detects reverse flow and
sends alarm message to the endpoint
until resolved .

Suspected leak
Encoder detects 24 hours
without one 15-minute
interval of no flow .

The alarm clears automatically
when a 15-minute no-flow
interval occurs .

Encoder detects suspected leak and
sends alarm message to the endpoint .

If condition clears before message is
sent to the endpoint, it is not reported .
30 day no usage
No measured flow in past
30 days .

The alarm is automatically
cleared once flow occurs .

Encoder detects 30 days no usage and
sends alarm to the endpoint .

If condition clears before message is
sent to the endpoint, it is not reported .

End of life
battery indicator

Indicated battery life based on
pre-calculated consumption .

Alarm activated at 19 years and
does not clear .

Encoder sends alarm to the endpoint
indefinitely . Permanent alarm after 19
years .

Page 11 ends

High Resolution LCD Encoders, HR-E® LCD, HR-E® LCD 4-20 www.badgermeter.com
GALAXY, HR-E, ORION, ReadCenter and Recordall are registered trademarks of Badger Meter, Inc . Other trademarks appearing in this document are the property of their respective entities . Due t continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists . © 2025 Badger Meter, Inc . All rights reserved .

Legacy Document Number: LCD-IOM-01-EN
City of Fullerton, RFP #2526-RFP-007 WATER METERS Request for Proposal (RFP) 2526-RFP-007, February 23, 2026

SMART WATER IS BADGER METER
Trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2026 Badger Meter, Inc. All rights reserved.
www.badgermeter.com
The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400 México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882 Europe, Eastern Europe Branch Office (for Poland, Latvia, Lithuania, Estonia, Ukraine, Belarus) | Badger Meter Europe | ul. Korfantego 6 | 44-193 Knurów | Poland | +48-32-236-8787 Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0 Europe, Middle East Branch Office | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503 Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01 Asia Pacific | Badger Meter | 80 Marine Parade Rd | 19-07 Parkway Parade | Singapore 449269 | +65-63464836 Switzerland | Badger Meter Swiss AG | Mittelholzerstrasse 8 | 3006 Bern | Switzerland | +41-31-932 01 11