Cities Index.
Agenda packet

Hanford City Council
July 18, 2023

Document
Agenda packet
Meeting
July 18, 2023
Body
Hanford City Council
Pages
665
Original file
70.3 MB
Text extracted from the city's file for reading and search. Open the original on hanfordca.api.civicclerk.com. That file is the official record.

0709438
Lights, Walk Surf, FRP Flood, LED

WALKING SURFACE LIGHT
There will be Model FRP,
4 " round black
12 volt DC LED floodlight(s) with bolt mount provided to illuminate the entire designated walking surface on top of the body.

The light(s) will be activated when the body step lights are on. 0518282
Pumper, PUC, Aluminum

0554271
Body Skirt Height, 20"

0543689
SP
Tank, Water, 550 Gallon, Poly,
Rectangle, Form Fitting, PUC

WATER TANK
Booster tank will have a capacity of
550
gallons and be constructed of UV stabilized ultra high
impact polypropylene plastic by a manufacturer with a minimum of 20 years experience building
tanks, is ISO
9001:2000
certified in all its manufacturing facilities, and has over 50,000
tanks in
service.

The booster tank will be a form-fitting design that serves to keep the tank height as low as possible. The tank shall be no wider than
39 " at the base to allow for greater compartment depth and no wider than
53 " at the top.

Tank joints and seams will be nitrogen welded inside and out.

Tank will be baffled in accordance with NFPA Bulletin
1901
requirements.

Baffles will have vent openings at both the top and bottom to permit movement of air and water between compartments.

Longitudinal partitions will be constructed of .
38 " polypropylene plastic and will extend from the
bottom of the tank through the top cover to allow for positive welding.

Transverse partitions will extend from

4.00 " off the bottom of the tank to the underside of the top cover.

All partitions will interlock and will be welded to the tank bottom and sides.

Tank top will be constructed of .
50 " polypropylene. It will be recessed .
38 " and will be welded to
the tank sides and the longitudinal partitions.

Tank top will be sufficiently supported to keep it rigid during fast filling conditions.

Construction will include

2.00 " polypropylene dowels spaced no more than

30.00 " apart and
welded to the transverse partitions. Two (
2 ) of the dowels will be drilled and tapped (.
50 "
diameter,

13.00 " deep) to accommodate lifting eyes.

A sump that will be sized dependent on the tank to pump plumbing will be provided at the bottom of the water tank.

Sump will include a drain plug and the tank outlet.

Tank will be installed in a fabricated cradle assembly constructed of structural steel.

Sufficient crossmembers will be provided to properly support bottom of tank. Crossmembers will be constructed of steel bar channel or rectangular tubing.

Tank will "float" in cradle to avoid torsional stress caused by chassis frame flexing. Rubber cushions, .
50 " thick x

3.00 " wide, will be placed on all horizontal surfaces that the tank rests on.

Stops or other provision will be provided to prevent an empty tank from bouncing excessively while moving vehicle.

Mounting system to be approved by the tank manufacturer. 0003405
Overflow, 4.00" Water Tank, Poly

Fill tower will be constructed of .
50 " polypropylene and will be a minimum of

8.00 " wide x

14.00 "
long.

Fill tower will be furnished with a .
25 " thick polypropylene screen and a hinged cover.

An overflow pipe, constructed of

4.00 " schedule
40 polypropylene, will be installed approximately
halfway down the fill tower and extend through the water tank and exit to the rear of the rear axle. 0028104
Foam Cell Required
0633066
Sleeve, Through Tank

SLEEVE, PLUMBING, THROUGH TANK
One (
1 ) sleeve
will be provided in the water tank for
a

2.50 " pipe
to the rear.
0553729
Not Required, Restraint, Water Tank,
Heavy Duty
0003429
Not Required, Direct Tank Fill

0003424
Not Required, Dump Valve

0048710
Not Required, Jet Assist

0030007
Not Required, Dump Valve Chute

0514778
Not Required, Switch, Tank Dump
Master
35 480
Bid #:

Page 474 of 665 ends

0597043
Body Height, PUC/HDRP

BODY HEIGHT
The height of the body will be

92.00 "
from the bottom of the body to the top of the body.
0199241
Hose Bed, Aluminum, Pumper, PUC

HOSE BED
The hose bed will be fabricated of .
125
"-
5052
aluminum with a nominal
38,000
psi tensile
strength.

Flooring of the hose bed will be removable aluminum grating with the top surface corrugated to aid in hose aeration. The grating slats will be a minimum of

0.50 " x

4.50 " with spacing between
slats for hose ventilation.
0723340
Unpainted/Brush Finished, Hose Bed,
3G PUC/HDRP
The hose bed walls will be unpainted and with a brushed finish. 0003481
Hose Bed Capacity, Special

Hose bed will accommodate
200' of 2.5", 1000' of 5", 600' of 3" and 600' of 3"
.
0689089
Divider, Hose Bed, Unpainted,
w/Handhold

HOSE BED DIVIDER
Three (
3 ) hosebed dividers
will be furnished for separating hose.

Each divider will be constructed of a .
125
" brushed aluminum sheet fitted and fastened into a
slotted,

1.50 " diameter radiused extrusion along the top, bottom, and rear edge.

An oval opening will be provided near the rear of the divider to be used as a hand hold and aid in accessing the hose bed.

Divider will be fully adjustable by sliding in tracks, located at the front and rear of the hose bed.

Divider will be held in place by tightening bolts, at each end.

Acorn nuts will be installed on all bolts in the hose bed which have exposed threads. 0010133
Cross-Divider, Hose Bed

A cross-divider will be provided just behind the fill tower. The divider will be bolted to the side sheet.
0530804
Cover, Hose Bed, Alum Treadplate

HOSE BED COVER
A two (
2 ) section hose bed cover, constructed of .
125
" bright aluminum treadplate will be
furnished. The cover will be hinged with full length stainless steel piano hinge. The sides will be slanted down. A stationary bridgework support assembly will be provided at the rear to support the cover.

The cover will be reinforced so that it can support the weight of a man walking on the cover.

The cover is designed with the left cover opening first.

If access to the water tank fill tower is blocked by the hose bed cover, then a hinged door will be provided in it so that the tank may be filled without raising cover doors.

Chrome grab handles and four (
4 ) gas filled cylinders will be provided to assist in opening and closing the cover. A handrail is to be provided at the rear, in the center of the support, to assist in opening the cover.

The hose bed cover will be connected to the Do Not Move Truck indicator. The light will be activated if the cover is not in the stowed position and the parking brake is released. 0587696
Hose Restraint, Hose Bed,One Piece
Vinyl Flap,Strap Fastener,Hose Bed
Frame,Rear

HOSEBED RESTRAINT REAR
There will be a
black
vinyl flap installed at the rear of the hosebed. The flap will be attached to the top hosebed frame with
quarter turn
fasteners. The flap will have straps that loop through
footman loops at the bottom of the hosebed and fasten with spring clip and hook
fasteners and
chain
.
0525658
Running Boards, PUC

RUNNING BOARDS
A running board will be provided on each side of the front body to allow access to the backboard/crosslay storage area. The running boards will be designed with a grip pattern punched into .
125
" bright aluminum treadplate material providing support, slip resistance, and drainage.
0683043
Tailboard, 12" Deep, Full Width,
Angled Corners, PUC/HDRP

TAILBOARD
The tailboard will be constructed of .
125
" bright aluminum treadplate and spaced .
50 " from the
body, as well as supported by a structural steel assembly.

The tailboard area will be

12.00 " deep and full width of the body. The outboard sides of the tailboard will be angled at
45 degrees beginning at the point where the body meets the tailboard at the outboard edge angling rearward to the rear edge of the tailboard.

The exterior side will be flanged down and in for increased rigidity of tailboard structure. 0690029
Wall, Rear, Body Material, PUC, PUC
Tanker, PRM, HDRP

REAR WALL, BODY MATERIAL, PUC
The rear wall will be smooth and the same material as the body.

The rear wall body material will be painted. Unpainted aluminum overlays will be provided to allow for chevron application and to provide continuously smooth rear wall panels.

The outboard edges of the rear wall will be trimmed in polished stainless steel. 36 480
Bid #:

Page 475 of 665 ends

0003531
Tow Bar, Under Tailboard

TOW BAR
A tow bar will be installed under the tailboard at center of truck.

Tow bar will be fabricated of

1.00 " CRS bar rolled into a

3.00 " radius.

Tow bar assembly will be constructed of .
38 " structural angle. When force is applied to the bar, it will be transmitted to the frame rail.

Tow bar assembly will be designed and positioned to allow up to a 30 -degree upward angled pull
of
17,000
lb, or a
20,000
lb straight horizontal pull in line with the centerline of the vehicle.

Tow bar design will have been fully tested and evaluated using strain gauge testing and finite element analysis techniques.
0656764
Construction, Compt, Alum, Pumper,
PUC

COMPARTMENTATION
The apparatus body will be built of aluminum construction using a minimum of

0.125
" thick,
5052
-
H
32 aluminum.

The body panel assembly will be constructed in a fixture and consist of formed sheet metal for the front and rear bulkheads, door frames, floors, ceilings, and back walls. These parts will be welded together to ensure greatest longevity with no visible welds in compartment interior.

Welded construction will consist of

1.00 " x

0.38 " engineered plug weld holes that control the size, location, and the amount of weld required. The bodies will be assembled and welded from engineered prints that call out the size, location, and type of weld required.

In structural areas the sheet metal components will have flanges for welding. No butt joints will be allowed. Gussets and support posts will be provided for additional strength where needed.

The fender panel will be an integral part of the complete welded body assembly. All light and compartment holes are pre punched prior to construction to provide accuracy and rounded corners to prevent stress risers in the material.

Circular fender liners will be provided. For prevention of paint chips and ease of suspension maintenance the fender liners will be formed from brush finished 304
L stainless steel, be
unpainted, and removable for suspension maintenance.

Side compartment flooring will be of the sweep out design with the floor minimum of

1.00 " higher
than the compartment door lip.

Drip protection will be provided above the doors by means of aluminum extrusion, or formed bright aluminum treadplate.

The top of the compartment will be sheet metal and covered with bright aluminum treadplate rolled over the edges on the front, and rear. These covers will have the corners welded.

The aluminum treadplate covers will not make up the ceiling of the compartment.

All screws and bolts, which are not Grade
8 , will be stainless steel and where they protrude into a compartment will have acorn nuts on the ends to prevent injury.

UNDERBODY SUPPORT SYSTEM
Due to the severe loading requirements of this pumper a method of body and compartment support suitable for the intended load will be provided.

The backbone of the body support system will begin with the chassis frame rails which is the strongest component of the chassis and is designed for sustaining maximum loads. The support system will include lateral frame rail extensions that are formed from

0.375
"
80 k high strength
steel and bolted to the chassis frame rails with

0.625
" diameter Grade
8 bolts.

The vertical and horizontal members of the frame rail extensions are to be reinforced with welded gussets and extend to the outside edge of the body. The lateral frame extensions will be electro- coated for superior corrosion resistance.

The floating substructure will be separated from the lateral frame extensions with neoprene elastomer isolators. These isolators will reduce the natural flex stress of the chassis from being transmitted to the body, and absorb road shock and vibration.

The isolators will have a broad load range, proven viability in vehicular applications, be of a fail safe design and allow for all necessary movement in three ( 3 ) transitional and rotational modes.

The neoprene isolators will be installed in a modified V three ( 3 )-point mounting pattern to reduce
the natural flex of the chassis being transmitted to the body. Two ( 2 )

3.50 " diameter isolators are
provided at the front of the body near the centerline of the vehicle above the chassis frame. A minimum of eight (
8 ) -

2.55 " diameter isolators will be provided, two (
2 ) under each front
compartment and two (
2 ) under each rear side compartment. A minimum of four ( 4 )

3.50 "
diameter isolators will be provided under the rear compartment.

AGGRESSIVE WALKING SURFACE
All exterior surfaces designated as stepping, standing, and walking areas will comply with the required average slip resistance of the current NFPA standards. Documentation of the material meeting the standard will be provided at time of delivery.

LOUVERS
All body compartments will have a minimum of one (
1 ) set of automotive style, dust resistant
louvers pressed into a wall. The louvers will incorporate a one ( 1 )-way rubber valve that provides
airflow out of the compartment and prevents water and dirt from gaining access to the compartment. Compartments over the wheel will not have louvers.

TESTING OF BODY DESIGN
Body structural analysis will be fully tested. Proven engineering and test techniques such as finite element analysis and strain gauging have been performed with special attention given to fatigue life and structural integrity of the body and substructure.

The body will be tested while loaded to its greatest in-service weight.

The criteria used during the testing procedure will include:

Raising opposite corners of the vehicle tires

9.00 " to simulate the twisting a truck may experience
when driving over a curb.

Making a
90 degree turn, while driving at
20 mph to simulate aggressive driving conditions.

Driving the vehicle on at
35 mph on a washboard road.

Driving the vehicle at
55 mph on a smooth road.

Accelerating the vehicle fully, until reaching the approximate speed of 45 mph on rough
pavement.

Evidence of the actual testing techniques will be made available upon request.

FEA will have been performed on all substructure components. 37 480
Bid #:

Page 476 of 665 ends

0518345
LS 177" Rollup, (1) 50" Fwd, (1) 52"
Rr, FH/FD Frt&Rr, PUC

LEFT SIDE COMPARTMENTATION
The left side compartmentation will consist of three rollup door compartments.

A full height, rollup door compartment ahead of the rear wheels will be provided. The pump operator's panel will be located in this compartment. The partition to the right of the pump operator's panel will be

2.50 "
in width. The interior dimensions of the remaining space in this compartment will be

13.25 " wide x

53.63 " high x

26.00 " deep. The clear door opening will be a
minimum of

47.25 " wide x

53.63 " high.

A rollup door compartment over the rear wheels will be provided. The interior dimensions of this compartment will be

60.00 " wide x

22.88 " high x

26.00 " deep. The clear door opening will be a
minimum of

57.25 " wide x

22.88 " high.

A full height, rollup door compartment behind the rear wheels will be provided.

The interior
dimensions of this compartment will be

51.75 " wide x

54.63 " high x

26.00 " deep. The clear
door opening will be a minimum of

49.25 " wide x

54.63 " high.

The roll up door spool will be installed in a recess above the compartment ceiling. All compartments will include a drip pan below the roll of the door. The drip pan will be installed level with the compartment ceiling. The interior height of the compartments will be measured from the compartment floor to the ceiling. The depth of the compartments will be measured from the back wall to the inside of the door frame.

Closing of the doors will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.
0518346
RS 177" Rollup, (1) 50" Fwd, (1) 52"
Rr, FH/FD Frt&Rr, PUC

RIGHT SIDE COMPARTMENTATION
The right side compartmentation will consist of three rollup door compartments.

A full height, rollup door compartment ahead of the rear wheels will be provided. The interior dimensions of this compartment will be

50.00 " wide x

54.50 " high x

25.88 " deep. The area behind
the roll up door spool will be notched for exterior storage or larger capacity water tank tee. The depth of the compartment will be calculated with the compartment door closed. The compartment interior will be fully open from the compartment ceiling to the compartment floor and designed so that no permanent dividers are required between the upper and lower sections. The clear door opening of this compartment will be

47.00 " wide x

54.50 " high.

A roll-up door compartment over the rear wheels will be provided. The interior dimensions of this compartment will be

60.00 " wide x

23.00 " high x

25.88 " deep. The area behind the roll up door
spool will be notched for exterior storage or larger capacity water tank tee. The depth of the compartment will be calculated with the compartment door closed. The clear door opening of this compartment will be

57.00 " wide x

23.00 " high.

A full height, roll-up door compartment behind the rear wheels will be provided.

The interior
dimensions of this compartment will be

52.00 " wide x

54.50 " high x

25.88 " deep. The area
behind the roll up door spool will be notched for exterior storage or larger capacity water tank tee. The depth of the compartment will be calculated with the compartment door closed. The compartment interior will be fully open from the compartment ceiling to the compartment floor and designed so that no permanent dividers are required between the upper and lower sections. The clear door opening of this compartment will be

49.00 " wide
x

54.50 " high.

The roll up door spool will be installed in a recess above the compartment ceiling. All compartments will include a drip pan below the roll of the door. The drip pan will be installed level with the compartment ceiling. The interior height of the compartments will be measured from the compartment floor to the ceiling. The depth of the compartments will be measured from the back wall to the inside of the door frame.

Closing of the doors will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.
0692733
Doors, Rollup, Gortite, Side
Compartments

SIDE COMPARTMENT ROLLUP DOOR(S)
There will be
six (
6 ) compartment doors
installed on the side compartments. The doors will be
double faced aluminum construction,
painted one (
1 ) color to match the lower portion of the body

and manufactured by Gortite®.

Lath sections will be an interlocking rib design and will be individually replaceable without complete disassembly of door.

Between each slat at the pivoting joint will be a PVC inner seal to prevent metal to metal contact and prevent dirt or moisture from entering the compartments. Seals will allow door to operate in extreme temperatures ranging from
180
to -
40 degrees Fahrenheit. Side, top and bottom seals
will be provided to resist ingress of dirt and weather and be made of Santoprene.

All hinges, barrel clips and end pieces will be nylon
66 . All nylon components will withstand
temperatures from
300
to -
40 degrees Fahrenheit.

A polished stainless steel lift bar to be provided for each roll-up door . Lift bar will be located at the
bottom of door and have latches on the outer extrusion of the doors frame. A ledge will be supplied over lift bar for additional area to aid in closing the door.

Doors will be constructed from an aluminum box section. The exterior surface of each slat will be flat. The interior surfaces will be concave to provide strength and prevent loose equipment from jamming the door from inside.

To conserve space in the compartments, the spring roller assembly will not exceed

3.00 " in
diameter.

The header for the rollup door assembly will not exceed

4.00 ".

A heavy-duty magnetic switch will be used for control of open compartment door warning lights. 38 480
Bid #:

Page 477 of 665 ends

0557309
Compt, Rear, Rollup, 40.50" FF,
w/Tailboard, PUC/HDRP

REAR COMPARTMENTATION
A roll-up door compartment above the rear tailboard will be provided. the interior dimensions of this compartment will be

37.00 " wide x

43.50 " high x

25.88 " deep in the
lower

34.00 " of the compartment and

15.00 " deep in the remaining upper portion. The clear door opening will be a minimum of

33.88 " wide x

33.63 " high.

A removable access panel will be furnished on the back wall of the compartment.

The rear compartment will be open into the rear side compartments. The transverse opening will be a minimum of

22.00 " wide x

29.00 " high.

A drip pan will be installed below the roll of the door. A guard will be installed behind the roll of the door. The interior height of the compartment will be measured from the floor to the ceiling. The depth of the compartment will be measured from the back wall to the inside of the door frame.

Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.
0692743
Door, Gortite, Rollup, Rear
Compartment, PUC

ROLLUP REAR COMPARTMENT DOOR
The rear compartment will have a rollup door. The door will be double faced aluminum construction,
an anodized satin finish
and manufactured by Gortite®.

Lath sections will be an interlocking rib design and will be individually replaceable without complete disassembly of door.

Between each slat at the pivoting joint will be a PVC inner seal to prevent metal to metal contact and prevent dirt or moisture from entering the compartments. Seals will allow door to operate in extreme temperatures ranging from
180
to -
40 degrees Fahrenheit. Side, top and bottom seals
will be provided to resist ingress of dirt and weather and be made of Santoprene.

All hinges, barrel clips and end pieces will be nylon
66 . All nylon components will withstand
temperatures from
300
to -
40 degrees Fahrenheit.

A polished stainless steel lift bar to be provided for each roll-up door . Lift bar will be located at the
bottom of door and have latches on the outer extrusion of the doors frame. A ledge will be supplied over lift bar for additional area to aid in closing the door.

Door will be constructed from an aluminum box section. The exterior surface of each slat will be flat. The interior surface will be concave to provide strength and prevent loose equipment from jamming the door from inside.

To conserve space in the compartments, the spring roller assembly will not exceed

3.00 " in
diameter.

The header for the rollup door assembly will not exceed

4.00 ".

A heavy-duty magnetic switch will be used for control of open compartment door warning lights. 0642304
Electric Door Locks, Body Doors,
Gortite

ELECTRIC DOOR LOCKS
There will be
seven (
7 )
door(s) located
LS
1 , LS
2 , LS
3 , B
1 , RS
1 , RS
2 , RS
3 equipped with electric
locks. The locks will be wired battery direct. The switch for control will be located on the driver
side switch panel
. In the event of loss of power, a manual override is available. 0689549
Lights, Compt, Pierce LED, Dual
Light Strips, Each Side of Door

COMPARTMENT LIGHTING
There will be
seven (
7 )
compartment(s) with two (
2 ) white
12 volt DC LED compartment light
strips. The dual light strips will be centered vertically along each side of the door framing. There will be two (
2 ) light strips per compartment. The dual light strips will be in compartment(s):
driver,
passenger sides, and rear compartments
.

Any remaining compartments without light strips will have a

6.00 " diameter Truck-Lite, Model:
79384
light. Each light will have a number
1076
one filament, two wire bulb.

Opening the compartment door will automatically turn the compartment lighting on. 0676393
SP
177" Hatch, (2) Lift-up, 21" Wide,
Both Sides, RS Shortened for Cargo
Area, PUC

HATCH COMPARTMENTS
Hatch compartments with two (
2 ) lift-up, top opening hatch doors will be provided above the left and right side body compartments. Hatch compartments will be provided above the side body compartmentation. Each side will be

21.00 " wide x

22.00 "
maximum depth. The length of the right
side hatch compartment will be shortened to provide additional space in the cargo area. A

20.00 "
recessed step area will be provided at the rear of the compartment on the access ladder side.

Sides of the compartments will be constructed of the same material as the body and painted job color on the outside panels. A

2.00 " tall formed aluminum painted to match the lower body color

will be provided to cover the seam between the top of the body panel and the bottom of the hatch compartment. The vertical outboard seam at the center of the compartment will have a painted
smooth weld
.

Top of the compartments will be constructed of bright aluminum treadplate.

Two (
2 ) lift-up, bright aluminum treadplate doors will be provided on the top of each hatch compartment. Each door will have a lever handle with a slam style latch to hold the doors in the closed position.

These double pan doors will have lipped edges with a rubber seal for weather resistance.

Doors will be hinged on the outboard side and will be held open with pneumatic stay arms.

The compartments will have a
3/4
" drain that extends to below the body.

Black rubber matting shall be provided to help prevent stored equipment in pooled water. will be
provided on the compartment floor to stop wet equipment from sitting in water pools. 0733406
Handrails, Hatch Step Area, (1)
Curved & (1) Straight
Handrails will be provided at the step area to the rear of the hatch compartment. One (1) curved handrail will be mounted on the outboard side of the step area at the rear and curve over the top.

One (1) straight handrail will be mounted vertically along the inboard side of the step area. 39 480
Bid #:

Page 478 of 665 ends

0687514
Lights, Hatch Compt, LED Strip Light,
177", Both Sides

HATCH COMPARTMENT LIGHTING
There will be LED strip lights mounted full length on the interior, hinged side of each compartment.

Opening the hatch compartment door will automatically turn the hatch compartment lighting on. 0687145
Shelf Tracks, Recessed, PUC/3rd
Generation

MOUNTING TRACKS
There will be recessed tracks installed vertically to support the adjustable shelf(s).

Tracks will not protrude into any compartment in order to provide the greatest compartment space and widest shelves possible.

The tracks will be provided in each compartment except for the one that contains the pump operator's panel.
0600350
Shelves, Adj, 500 lb Capacity, Full
Width/Depth, Predefined Locations

ADJUSTABLE SHELVES
There will be
eight (
8 ) shelves
with a capacity of
500
lb provided.

The shelf construction will consist of .
188
" aluminum
painted spatter gray
with

2.00 " sides.

Each shelf will be infinitely adjustable by means of a threaded fastener, which slides in a track.

The shelves will be held in place by .
12 " thick stamped plated brackets and bolts.

The location(s) will be
in RS
1 centered between the floor and the ceiling, in RS
3 centered
between the floor and the ceiling, in RS
3 in the upper third, in RS
2 in the upper third, in RS
1 in
the upper third, in LS
1 centered between the floor and ceiling, in LS
2 in the upper third and in
LS
1 in the upper third
.
0709689
Tray, 500 lb Slide-out, 2" Sides - Adj.

Height, Predefined Locations

SLIDE-OUT ADJUSTABLE HEIGHT TRAY
There will be
three (
3 ) slide-out trays
provided.

Each tray will have

2.00 " high sides and a minimum capacity rating of
500
lb in the extended
position.

Each tray will be constructed of aluminum
painted spatter gray
.

Each tray will be mounted on a pair of side mounted slides. The slide mechanisms will have ball bearings for ease of operation and years of dependable service. The slides will be mounted to shelf tracks to allow the tray to be adjustable up and down within the designated mounting location.

An automatic lock will be provided for both the in and out tray positions. The lock trip mechanism will be located at the front of the tray and will be easily operated with a gloved hand.

The location(s) will be
in LS
3 centered between the floor and ceiling to right of the partition, in LS
3 in the upper third to the right of the partition and in LS 3 in the lower third to the right of the
partition
0667235
Cable, Single Hand Operation,
Tilt/Slide Out, Utility Trays

SINGLE HANDED CABLE LATCH
A cable will be provided to tie together the two (
2 ) spring loaded locks that are provided as
standard at the front of a slide-out/tilt tray in order to provide single hand operation of the tray.

The single hand operation cable will be provided on a total of two (
2 ) slide-out trays
located
One
(
1 ) LS
2 and One (
1 ) in RS
2 .
0635427
SP
Tray, 215 lb, Tilt/Slide-Out, 30 Deg,
Adj, Painted, Max Width/Depth, 3G

SLIDE-OUT/TILT-DOWN TRAY
There will be
two (
2 ) slide-out trays
provided.

The bottom of each tray will constructed of

0.188
" thick aluminum while special aluminum
extrusions will be utilized for the tray sides, ends, and tracks. The corners will be welded to form a rigid unit.

Each tray will be designed as wide and as deep as the compartment will allow.

Each tray will be painted spatter gray to match the compartment it is mounted in.

A spring loaded lock will be provided on each side at the front of the tray. Releasing the locks will allow the tray to slide out approximately two-thirds (
2/3
) of its length from the stowed position and
tip
30 degrees down from horizontal. The tray will be equipped with ball bearing rollers for smooth operation.

Rubber padded stops will be provided for the tray in the extended position.

The capacity rating of the tray will be a minimum of
215
lb in the extended position.

The vertical position of the tray within the compartment will be adjustable.

The tray(s) will be located
One (
1 ) in LS
2 and One (
1 ) in RS
2 .
0647772
Tray, Floor Mounted, Slide-Out,
500lb, 2.00" Sides, 3G

SLIDE-OUT FLOOR MOUNTED TRAY
There will be
three (
3 )
floor mounted slide-out tray(s) with

2.00 " sides provided
LS
1 , B
1 and RS
1 .

Each tray will be rated for up to
500
lb in the extended position. The tray(s) will be constructed of .
19 " aluminum with non-welded corners. The finish will be painted spatter gray
.

There will be two undermount-roller bearing type slides rated at 250
lb each provided. The pair of
slides will have a safety factor rating of
2 .

To ensure years of dependable service, the slides will be coated with a finish that is tested to withstand a minimum of
1,000
hours of salt spray per ASTM B
117
.

To ensure years of easy operation, the slides will require no more than a 50 lb force for push-in or
pull-out movement when fully loaded after having been subjected to a 40 hour vibration (shaker)
test under full load. The vibration drive file will have been generated from accelerometer data collected from a heavy truck chassis driven over rough gravel roads in an unloaded condition.

Proof of compliance will be provided upon request.

Automatic locks will be provided for both the "in" and "out" positions. The trip mechanism for the locks will be located at the front of the tray for ease of use with a gloved hand. 40 480
Bid #:

Page 479 of 665 ends

0726412
Partition, Trans Rear Compt,

PUC/HDRP

PARTITION, TRANSVERSE REAR COMPARTMENT
One (
1 ) partition
will be bolted in place to separate the
left side rear compartment
from the rear
tailboard compartment. The partition will be body material with a brushed finish
.
0762913
Divider, Vertical

VERTICAL DIVIDER
A .
12 " thick aluminum vertical compartment divider will be provided Ahead of the upper crosslay
and as wide as possible while still being able to open the door fully and remove backboard or long handle tool. Match previous Job
26797
. The divider will be secured in place with
#10
self
tapping screws.

A total of
one (
1 )
will be provided.
0004020
Rub Rail, Stainless Steel

RUB RAIL
The bottom edge of the side compartments will be trimmed with a bright stainless steel rub rail.

The rub rail will be

2.00 " high and extend

1.00 " away from the body, with slanted ends to provide a pleasing appearance.

These rub rails will not be an integral part of the body construction, which allows replacement in the event of damage.
0515441
Fender Crowns, Rear, S/S,
W/Removable Fender Liner, Pumper,
3G

BODY FENDER CROWNS
Polished stainless steel fender crowns will be provided around the rear wheel openings.

A fender liner constructed of
unpainted brushed stainless
will be provided to avoid paint chipping.

The liners will be removable to aid in the maintenance of rear suspension components.

A dielectric barrier will be provided between the fender crown fasteners (screws) and the fender sheet metal to prevent corrosion.

The fender crowns will be held in place with stainless steel screws that thread directly into a composite nut and not directly into the parent body sheet metal to eliminate dissimilar metals contact and greatly reduce the chance for corrosion.
0519849
Not Required, Hose, Hard Suction

HARD SUCTION HOSE
Hard suction hose will not be required.
0527021
Handrails Located @ Front Body

HANDRAILS
The handrails will be

1.25 " diameter knurled aluminum to provide a positive gripping surface.

Chrome plated end stanchions will support the handrail. Plastic gaskets will be used between end stanchions and any painted surfaces.

Drain holes will be provided in the bottom of all vertically mounted handrails..

Handrails will be located on the front of the body in positions needed to meet NFPA requirements. 0664688
Handrails, Rear, PUC/HDRP

Two (2) vertical handrails will be located at the rear, one on each side of the rear compartment . 0000941
No Rear Hose Bed Handrail Required

0657651
Compt, Air Bottle, Double, Fender
Panel
AIR BOTTLE STORAGE (Double)
A quantity of
three (
3 ) air bottle compartments
,

15.25 " wide x

7.75 " tall x

26.00 " deep, will be
provided
on the left side forward of the rear wheels, on the right side forward of the rear wheels and on the right side rearward of the rear wheels
. A
polished
stainless steel door with a
chrome
plated flush lift & turn latch
will be provided to contain the air bottle. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body sheet metal.

Inside the compartment,
black rubber matting
will be provided.
0004225
Ladder, 24' Duo-Safety 900A 2-
Section

EXTENSION LADDER
There will be a
24 ' two-section aluminum Duo-Safety Series
900
-A extension ladder provided.
0004230
Ladder, 14' Duo-Safety 775A Roof

ROOF LADDER
There will be a
14 ' aluminum Duo-Safety Series
775
-A roof ladder provided.
0638384
Rack, Ladders, RS Full Depth Body,

PUC/HDRP

LADDER STORAGE
The ladders will be stored inside the upper section of the right side compartments. This ladder rack will reduce the depth of the upper section in the side compartments.

A partition will be installed inside the compartment on the side of the rack to allow for equipment storage and to conceal the ladders.

The ladders will be banked in separate storage troughs.

The ladder storage assembly will be fabricated of stainless steel track channels to aid in loading and removal of ladders.

Rear of the ladder storage area will have a vertically hinged smooth aluminum
door with a
D-
handle latch
to contain the ladders.
41 480
Bid #:

Page 480 of 665 ends

0733387
Ladder, 10' Duo-Safety Folding 585A

FOLDING LADDER
One (
1 )

10.00 ' aluminum, Series
585
-A, Duo-Safety folding ladder will be installed.
0554061
Pike Pole, 10' DUO Safety,
Fiberglass, Pumper NFPA
Classification
10 ' PIKE POLE
One (
1 ) pike pole

10 ' long DUO Safety with a fiberglass handle will be provided. 0733370
Pike Pole, 6' DUO Safety, Fiberglass

PIKE POLE,
6 '
One (
1 ) pike pole
,
6 ' long Duo Safety with a fiberglass handle, will be provided. 0608351
SP
Compt, Pike Poles/Fld Ldr In Upper
Bdy (1) RS, Long Storage (1) LS,
Latch, PUC

PIKE POLE/FOLDING LADDER COMPARTMENT
One (
1 ) pike pole compartment will be provided, recessed in the upper, inside part of body compartment on the right side. The compartment will be equipped with two ( 2 ) aluminum tubes to
hold two (
2 ) pike poles and a stainless steel trough for the folding ladder. The door will be made of
smooth aluminum
and have a
flush lift and turn latch
.

One (
1 ) compartment will be provided, recessed in the upper, inside part of body compartment on the left side for storage of long handle tools. The door will be made of [Door, Material, Storage]

and have a
[Latch, Door, Storage]
.
0058193
Tubes, Alum, Pike Pole Storage, Spcl
Notch, NY PP Head

PIKE POLE STORAGE
Aluminum tubing will be used for the storage of
one (
1 ) pike pole
and will be located
Upper
Crosslay long tool storage compartment (Option
735116
) Exact location TBS at Pre-con
. If the
head of a pike pole can come in contact with a painted surface, a stainless steel scuffplate will be provided. The pike pole tube will be notched to allow a New York style pike pole to fit into the tube.
0521734
No Steps Required, Front Of Body,
PUC
0515521
Ladder, Top Access, Alum, LH Rear,

PUC/HDRP

LADDER, TOP ACCESS
A wide easy climbing access ladder, constructed of aluminum rungs and extruded aluminum rails, will be provided on the left side at the rear of the apparatus. The inside climbing area of the ladder will be

13.75 " wide.

The lower section of the ladder will be retractable into the upper section to eliminate interference with the rear FMVSS lights. When lowered the bottom rung will be lower than the body, approximately

16.00 " to

20.00 " from the ground to allow a lower first step height.

The ladder will be slanted when in use for easy access, and fold against the body for storage to reduce the overall length. Corrosion resistant, stainless steel spring-loaded locks will hold the ladder in place.

There will be
a "do not move truck" indicator
activated in the cab if the ladder is not in the stowed position when the parking brake is disengaged.
0515692
Pump Operators Panel, 31", Control
Zone, PUC
PUMP CONTROL PANELS (Left Side Control)
Pump controls and gauges will be located midship at the left side of the apparatus and properly identified.

The main pump operator's control panel will be completely enclosed and located in the forward section of the body compartment, to protect against road debris and weather elements. The pump operator's panels will be no more than

31.00 " wide, and made in four (
4 ) sections with the
center section easily removable with simple hand tools. For the safety of the pump operator, there will be no discharge outlets or pump inlets located on the main pump operators panel.

Layout of the pump control panel will be ergonomically efficient and systematically organized.

The upper section will contain the master gauges. This section will be angled down for easy visibility. The center section will contain the pump controls aligned in two horizontal rows. The pressure control device, engine monitoring gauges, electrical switches, and foam controls (if applicable) will be located on or adjacent to the center panel, on the side walls for easy operation and visibility. The lower section will contain the outlet drains.

Manual controls will be easy moving
8 " long lever style controls that operate in a vertical, up and down swing motion. These handles will have a

2.25 " diameter knob and be able to lock in place
to prevent valve creep under any pressure. Bright finish bezels will encompass the opening, be securely mounted to the pump operator's panel, and will incorporate the discharge gauge bezel.

Bezels will be bolted to the panel for easy removal and gauge service. The left side discharges will be controlled directly at the valve. There will be no push-pull style control handles.

Identification tags for the discharge controls will be recessed within the same bezel. The discharge identification tags will be color coded, with each discharge having its own unique color.

All remaining identification tags will be mounted on the pump panel in chrome-plated bezels.

All discharge outlets will be color coded and labeled to correspond with the discharge identification tag.

The pump panels for the midship discharge and intake ports will be located ahead of the body compartments with no side discharge or intake higher than the frame rail. The pump panels will be easily removable with simple hand tools.

A recessed cargo area will be provided at the front of the body, ahead of the water tank above the plumbing.
0520016
Not Required, Pumphouse Structure,
PUC
42 480
Bid #:

Page 481 of 665 ends

0889385
Pump, Pierce, 1500 GPM, Single
Stage, PUC-NG

PUMP
Pump will be a Pierce, low profile,
1500
gpm single stage midship mounted centrifugal type,
mounted below the cab. The pump will have a
15 percent reserve capacity to allow for extended
time between pump rebuild. To ensure efficient pump/vehicle design the capacity to weight ratio will not be less than

1.5:1
.

The pump casing will consist of three (
3 ) discharge outlets, one (
1 ) to each side in line with the
impeller and one (
1 ) to the rear. The pump casing will incorporate two ( 2 ) water strippers to
maintain radial balance.

Pump will be the Class A type.

Pump will be certified to deliver the percentage of rated discharge from draft at pressure indicated below:
100
percent of rated capacity at
150
psi net pump pressure
70 percent of rated capacity at
200
psi net pump pressure
50 percent of rated capacity at
250
psi net pump pressure
The pump will have the capacity to deliver the percentage of rated discharge from a pressurized source as indicated below:
135
percent of rated capacity at
100
psi net pump pressure from a
5 psi source
Pump body will be fine-grained gray iron. Pump will incorporate a heater/cooling jacket integral to the pump housing.

The impeller will be high strength vacuum cast bronze alloy accurately machine balanced and splined to a
10 spline stainless steel pump shaft for precision fit, exceptional durability, and efficiency. Double replaceable reverse flow labyrinth type bronze wear ring design will help to minimize end thrust. The impeller will be a twisted vane design to create higher lift.

The pump will include o-ring gaskets throughout the pump.

Deep groove radial type oversize ball bearings will be provided. The bearings will be protected at the openings from road dirt and water with an oil seal and a water slinger.

The pump will have a flat, patterned area on the top of the pump intake wye to allow standing for plumbing maintenance. The main inlet manifold will be

6.00 " in diameter and will have a low
profile design to facilitate low crosslays and high flows.

For ease of service, the pump housing, intake wye, impeller, mechanical seal, and gear case will be accessible from above the chassis frame by tilting the cab. Removal of the main inlet wyes will provide access to the impeller, mechanical seal, and wear ring.

The tank to pump line and the primary discharge line will be the only piping required to be removed for overhaul.

For ease of service and overhaul there will be no piping or manifolding located directly over the pump.

PUMP MOUNTING
Pump will be mounted to the chassis frame rails directly below the crew cab, to minimize wheelbase and facilitate service, using rubber isolators in a modified V pattern that include one (
1 ) central mounted isolators located between the frame rails, and one ( 1 ) on each side outside
the frame rails. The mounting will allow chassis frame rails to flex independently without damage to the fire pump. Each isolator will be

2.55 " in total outside diameter and will be rated at
490
lb.

The pump will be completely accessible by tilting the cab with no piping located directly above the pump.
0515822
Seal, Mechanical, Silicon Carbide,
PUC Pump

MECHANICAL SEALS
Silicon carbide mechanical seals will be provided. The seals will be spring loaded and self- adjusting. The seals will have a minimum thermal conductivity of 126
W/m*K to run cooler. Seals
will have a minimum hardness of
2800
kg/mm
2 to be more resistant to wear, and have thermal
expansion characteristics of no more than

4.0 X
106
mm/mm*K to be more resistant to thermal
shock.
0802234
Gear Case, Integrated Pump
Transmission, PUC-NG, Cummins

PUMP GEAR CASE
The integrated pump transmission gear case will use a pressure-lubricated system to cool, lubricate, and filter the oil. The gear case will be constructed of lightweight aluminum, and impregnated with resin in accordance to MIL Spec MIL-I- 17563
. A sight glass, accessible by
tilting the cab, will be provided for easy fluid level checks.

The gear case will consist of three (
3 ) gears to drive the pump.

CLUTCH
There will be a heavy-duty hydraulic clutch mounted directly to the integrated pump transmission to engage and disengage the pump without gear clash. The clutch will be a multiple disc design for maximum torque. The clutch will be fully self-adjusting to provide automatic wear compensation, and consistent torque throughout the life of the clutch. Positive engagement and disengagement will be provided through a high efficient and dependable hydraulic system to assure superior performance.

LOW PRESSURE/HIGH TEMPERATURE LIGHTS
Lights will be provided to indicate when a high temperature or low pressure situation occurs.

Lights will be provided next to the master gauges at the pump panel as well as on the control panel in the cab. A pair of lights will be provided in each location. One ( 1 ) light will be provided to
indicate high temperature. The second light will be provided to indicate a low pressure. All lights will be labeled accordingly.
43 480
Bid #:

Page 482 of 665 ends

0721196
Pumping Mode, Pump and
Roll/Stationary, Basic, MUX, PUC,
No Cab Foam Switch

PUMPING MODE
Pump will provide for both pump and roll mode and stationary pumping mode.

Stationary pumping mode will be accomplished by stopping the vehicle, setting the parking brake and engaging the water pump switch on the cab switch panel. The transmission will shift to "Neutral" range automatically when the parking brake is set. The "OK to Stationary Pump" indicator will also illuminate when the parking brake is set.

If the vehicle is equipped with a suitable Husky foam system or Hercules CAFS system, these systems will be engaged from the cab switch panel as well.

Pump and roll mode will be accomplished by the use of the main pump and will not require the use of a secondary pump. Pump and roll mode will use the same operation sequence as stationary pumping mode with a few additional steps. After the vehicle is setup for stationary pumping, the operator will leave the cab and setup the pump panel to discharge at the desired outlet(s). Upon returning to the cab, the operator will disengage the parking brake. An "OK to Pump & Roll" indicator will illuminate on the cab switch panel. First gear on the transmission gear selector will be selected by the operator for pump and roll operations. The operator as needed will apply the foot throttle. Pump and roll mode will be maintained unless the transmission shifts out of first gear.

Stopping either stationary pumping mode or pump and roll mode will be accomplished by pressing the "Water Pump" switch down to disengage the pump.

A pump pressure reading will be displayed in view of the driver. 0515829
Pump Shift, Sure-Shift

PUMP SHIFT
Pump will be engaged in not more than two steps, by simply setting the parking brake, which will automatically put the transmission into neutral, and activating a rocker switch in the cab. Switches in the cab will also allow for water, foam, or CAFS if equipped, and activate the appropriate system to preset parameters. The engagement will provide simple two-step operation, enhance reliability, and completely eliminate gear clash. The shift will include the indicator lights as mandated by NFPA. A direct override switch will be located behind a door in the lower pump operator's panel. The switch will automatically disengage when the door is closed.

As the parking brake is applied, the pump panel throttle will be activated and deactivate the chassis foot throttle for stationary operation.
0515833
Transmission Lock-up, Not Req'd,
Park to Neutral, Pump, PUC

TRANSMISSION LOCK UP
Transmission lock up is not required as transmission will automatically shift to neutral as soon as the parking brake is set.
0515835
Auxiliary Cooling System, PUC

AUXILIARY COOLING SYSTEM
A supplementary heat exchange cooling system will be provided to allow the use of water from the discharge side of the pump for cooling the engine water. A water-to-coolant heat exchanger will be used.
0014486
Not Required, Transfer Valve, Single
Stage Pump
0746501
Valve, Relief Intake, Elkhart

INTAKE RELIEF VALVE - PUMP
There will be
One (
1 )
Elkhart Style
40 relief valve(s) installed on the suction side of the pump preset at
125
psig
.

The relief valve(s) will have a working range of
75 psi to
250
psi.

The outlet will terminate below the frame rails with a

2.50 " National Standard hose thread adapter
and will have a "do not cap" warning tag.

The relief valve pressure control will be located behind behind the right side pump panel with a
stainless steel access door
.
44 480
Bid #:

Page 483 of 665 ends

0724463
Controller, Pressure, Pierce LCD,
PUC

PIERCE PRESSURE CONTROLLER
A Pierce electronic pressure controller will be provided.

A pressure transducer will be installed in the discharge side of the water pump. The transducer continuously monitors pump pressure sending a signal to the electronic pressure controller.

The pressure controller can be used in two (
2 ) modes of operation, RPM mode and pressure
modes. The controller will be programmed to turn on/default to No Mode/Default Press Setting

mode.

In the RPM mode, the controller can be activated after vehicle parking brake has been set. When in this mode, the controller will maintain the set engine speed, regardless of engine load (within engine operation capabilities).

In the pressure mode, the controller can be activated after vehicle parking brake has been set.

When in this mode, the controller will automatically maintain the discharge pressure set by the operator (within the discharge capabilities of the pump and water supply) regardless of flow.

A

2.00 " diameter throttle control knob with no mechanical stops, a serrated grip, and a red idle push button in the center will be a integrated/part of the pressure controller. The throttle control knob will be programmed for
Clockwise
rotation to increase engine speed.

Individual LED indicators for ok to pump, throttle ready, pressure mode and rpm mode will be located on the pressure controller for easy viewing.

A pump cavitation protection feature will also provided which will return the engine to idle should the pump cavitate. Cavitation is sensed by the combination of pump pressure below 30 psi and
engine speed above
2000
rpm for more than five (
5 ) seconds.

Other safety features include recognition of low water and no water conditions with an automatic programmed response and a push button to return the engine to idle.

The pressure controller LCD screen will be

4.20 " in size with a minimum brightness of
750
nits.

The LCD screen and LED intensity will be automatically adjust for day and nighttime operation.

The LCD screen intensity can also be manually adjusted if needed.

The following information will be provided/displayed on the LCD screen - Engine RPM
Check engine and stop engine warning indicators
Engine oil pressure
Engine coolant temperature
Water pump temperature
Fuel Level
Water tank level
Battery voltage
Operating mode (RPM or pressure)
Pressure or RPM setting
On screen messaging show diagnostic and warning messages as they occur. It will show apparatus information, stored data, and program options when selected by the operator. It will monitor inputs outputs and support audible and visual warning alarms for the following conditions -
High battery voltage
Low battery voltage/engine off
Low battery voltage/engine running
High water pump temperature
Low fuel
Low engine oil pressure
High engine coolant temperature
Water tank out of water (visual alarm only)
No engine response (visual alarm only)
The pressure controller will store the accumulated operating hours for the pump and engine.

These items are to be displayed within the pressure controller menu.

The pressure controller will include a USB port on the back of the controller for easy software upgrades if needed.
0072153
Primer, Trident, Air Prime, Air
Operated

PRIMING PUMP
The priming pump will be a Trident Emergency Products compressed air powered, high efficiency, multistage venturi based AirPrime System, conforming to standards outlined in the current edition of NFPA
1901
.

All wetted metallic parts of the priming system are to be of brass and stainless steel construction.

One (
1 ) priming control will open the priming valve and start the pump primer. 0780359
Manuals, Pump, (2) Total, Electronic
Copies, Pierce PUC Pump

PUMP MANUALS
There will be a total of two (
2 ) pump manuals provided by the pump manufacturer and furnished with the apparatus. The manuals will be provided by the pump manufacturer in the form of two ( 2 )
electronic copies. Each manual will cover pump operation, maintenance, and parts. 0602496
Plumbing, Stainless Steel and Hose,
Single Stage Pump, PUC

PLUMBING, STAINLESS STEEL AND HOSE
All inlet and outlet lines will be plumbed with either stainless steel pipe, flexible polypropylene tubing or synthetic rubber hose reinforced with hi-tensile polyester braid. All hose's will be equipped with brass or stainless steel couplings. All stainless steel hard plumbing will be a minimum of a schedule
10 wall thickness.

Where vibration or chassis flexing may damage or loosen piping or where a coupling is required for servicing, the piping will be equipped with victaulic or rubber couplings.

Plumbing manifold bodies will be ductile cast iron or stainless steel.

All piping lines are to be drained through a master drain valve or will be equipped with individual drain valves. All drain lines will be extended with a hose to drain below the chassis frame.

All water carrying gauge lines will be of flexible polypropylene tubing.

All piping, hose and fittings will have a minimum of a
500
PSI hydrodynamic pressure rating.
45 480
Bid #:

Page 484 of 665 ends

0795135
Plumbing, Stainless Steel, w/Foam
System

FOAM SYSTEM PLUMBING
All piping that is in contact with the foam concentrate or foam/water solution will be stainless steel. The fittings will be stainless steel or brass. Cast iron pump manifolds will be allowed. 0517852
Inlets, 6.00" - 1250-2000 GPM,
Pierce PUC Pump

MAIN PUMP INLETS
A

6.00 " pump manifold inlet will be provided on each side of the vehicle. The suction inlets will include removable die cast zinc screens that are designed to provide cathodic protection for the pump, thus reducing corrosion in the pump.

Main pump inlets will not be located on the main operator's panel and will maintain a low connection height by terminating below the top of the chassis frame rail. 0730359
Valve, Ball Intake, TFT, ABD Series

INLET VALVES WITH INTAKE RELIEF VALVE
There will be
Two (
2 )
Task Force Tips (TFT) ABD Series manually operated aluminum ball intake valve(s) provided at
At pump main inlets
.

The inlet connection will be
7 NR (

4.5 " Threaded Swivel)
with a matching and the outlet
connection will be
NX (

6.0 " Threaded Swivel)
.

The ball intake valve will be controlled with a NFPA compliant slow-close hand wheel. A position indicator will be provided to allow for a quick visualization of the status of the valve in the open, closed or transition position.

The ball intake valve will be equipped with
standard
adjustable pressure relief valve. The relief
valve will have a working range of
90 PSI to
300
PSI.

A
3/4
" TFT bleeder/drain valve will be provided on the ball intake valve to exhaust excess air or water from the valve.

For corrosion protection the aluminum casting will have a hard coat anodized finish, with a powder coated internal and external finish. All the components facing the wet side of the valve will be constructed from stainless steel.
0004646
Cap, Main Pump Inlet, Long Handle,

NST, VLH

MAIN PUMP INLET CAP
The main pump inlets will have National Standard Threads with a long handle chrome cap.

The cap will be the Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0687773
Valves, Elkhart Unibody - All Ball
Valves, PUC
VALVES
All ball valves will be Elkhart Unibody series. Seats will be self-adjusting for minimum operating torque and maximum abrasion resistance. The Elkhart valves will have an automatic locking feature to hold the ball in any throttle position at any operating pressure. The valve body design will allow any actuator to be mounted to the body.
0520002
Valve, Inlet(s) Recessed, Side Cntrl,
PUC
The location of the valve for the
two (2) inlets
will be recessed behind the pump panel.
0004700
Control, Inlet, at Valve

INLET CONTROL
The side auxiliary inlet(s) will incorporate a quarter-turn ball valve with the control located at the inlet valve. The valve operating mechanism will indicate the position of the valve. 0004660
Inlet (1), Left Side, 2.50"

LEFT SIDE INLET
There will be one (
1 ) auxiliary inlet with a

2.50 " valve at the left side pump panel, terminating with a

2.50 " (F) National Standard hose thread adapter.

The auxiliary inlet will be provided with a strainer, chrome swivel and plug. 0004680
Inlet, Right Side, 2.50"

RIGHT SIDE INLET
There will be one (
1 ) auxiliary inlet with a

2.50 " valve at the right side pump panel, terminating
with a

2.50 " (F) National Standard hose thread adapter.

The auxiliary inlet will be provided with a strainer, chrome swivel and plug. 0521137
Anode, Zinc, Pair, Pump Inlets, PUC

ANODE, INLET
A pair of sacrificial zinc anodes will be provided in the water pump inlets to protect the pump from corrosion.
0650999
No Front Inlet (Large Dia) Requested

0064119
No Actuation Req'd

0009606
No Intake Relief Valve Required on
Front Inlet
0650998
Not Required, Elbow/Swivel/Adapter,
Front Suction
46 480
Bid #:

Page 485 of 665 ends

0521688
Not Required, Cap, Long Handle,
Front Inlet, Pre-connected Hose

0092569
No Rear Inlet (Large Dia) Requested

0064116
No Rear Inlet Actuation Required

0092696
Not Required, Cap, Rear Inlet

0009648
No Rear Intake Relief Valve Required
on Rear Inlet
0092568
No Rear Auxiliary Inlet Requested

0723049
Valve, .75" Bleeder, Aux. Side Inlet,
"T" Swing Handle

INLET BLEEDER VALVE
A

0.75 " bleeder valve will be provided for each side gated inlet.

The valves will be located behind the panel with a "T" swing style handle control extended to the outside of the panel.

The handles will be chrome plated and provide a visual indication of valve position. The swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage.

The water discharged by the bleeders will be routed below the chassis frame rails. 0520277
Tank to Pump, (1) 3.00" Valve, 4.00"
Plumbing, PUC

TANK TO PUMP
The booster tank will be connected to the intake side of the pump with heavy duty

4.00 " piping
and a quarter turn

3.00 " full flow line valve with the control located at the operator's panel. A rubber coupling will be included in this line to prevent damage from vibration or chassis flexing.

A check valve will be provided in the tank to pump supply line to prevent the possibility of "back filling" the water tank.
0595508
Outlet, Tank Fill, 1.50", PUC

TANK REFILL
A

1.50 " combination tank refill and pump re-circulation line will be provided, using a quarter-turn full flow ball valve controlled from the pump operator's panel. 0740455
Control, Outlets, Swing Handle, Elect
RS Outlets Elkhart Apex w/Press
Disp, PUC

DISCHARGE OUTLET CONTROLS
The discharge outlets will incorporate a quarter-turn ball valve with the control located at the pump operator's panel. The valve operating mechanism will indicate the position of the valve or an indicator will be provided to show when the valve is closed.

The right side discharges will be controlled by an Elkhart Apex electric valve controller with the manual override located on the right side pump panel. The controller unit will provide position feedback with a LED display that indicates closed to fully open status. The controller will be completely sealed with two (
2 ) button open and close valve position. In addition to valve position, each controller will include a pressure display.

All other outlets will have manual swing handles that operate in a vertical up and down motion.

These handles will be able to lock in place to prevent valve creep under pressure. 0516755
Outlet, Left Side, 2.50" (2), PUC

LEFT SIDE DISCHARGE OUTLETS
There will be two (
2 ) discharges with a

2.50 " valves on the left side of the apparatus, terminating with a

2.50 " (M) National Standard hose thread adapter. Discharges will be located below the cab, and will be no higher than the top of the chassis frame rail. Discharges will not be located on the pump operator's panel. Lever controls will be provided at the valve. 0539271
Elbow, Left Side Outlets, 30 Degree,

2.50"FNST x 2.50" MNST, VLH, PUC

LEFT SIDE OUTLET ELBOWS
The

2.50 " discharge outlets, located on the left side pump panel, will be furnished with a

2.50 " (F)
National Standard hose thread x

2.50 " (M) National Standard hose thread, chrome plated, 30 degree elbow.

The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0092570
Not Required, Outlets, Left Side
Additional
0035094
Not Required, Elbow, Left Side
Outlets, Additional
47 480
Bid #:

Page 486 of 665 ends

0746573
Outlet, Right Side, 2.50", (1), Elec,
Elk, Apex Cont, Press, PUC

RIGHT SIDE DISCHARGE OUTLET
There will be one (
1 ) discharge with a

2.50 " valve on the right side of the apparatus, terminating with a

2.50 " (M) National Standard hose thread adapter. The discharge will be located below the crew cab, and will be no higher than the top of the chassis frame rail.

The valve will be controlled with an Elkhart Apex electric valve controller provided on the pump operators panel. The electric control must be of a true position feedback design, requiring no clutches in the motor or current limiting. The controller will have momentary open, close as well as programmable preset valve positions. The controller will provide position indication on a full color, backlit LCD display. It will have manual adjustment of the brightness as well as an auto dimming option.

In addition to valve position, each controller will include a pressure display. 0539269
Elbow, Right Side Outlets, 30
Degree, 2.5" FNST x 2.5" MNST,

VLH, PUC

RIGHT SIDE OUTLET ELBOWS
The

2.50 " discharge outlets, located on the right side pump panel, will be furnished with a

2.50 "
(F) National Standard hose thread x

2.50 " (M) National Standard hose thread, chrome plated, 30 degree elbow.

The elbow will be the Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0092571
Not Required, Outlets, Right Side
Additional
0089584
Not Required, Elbow, Right Side
Outlets, Additional
0808874
SP
Outlet, Right Side, 4" w/4" Valve,
Elec, Elk, Dual Apex Cont, Press,
PUC

LARGE DIAMETER DISCHARGE OUTLET
There will be one (
1 ) discharge with a

4.00 " valve on the right side of the apparatus, terminating with a

4.00 " (M) National Standard hose thread adapter. The discharge will be located below the crew cab, and will be no higher than the top of the chassis frame rail.

The valve will be controlled with an Elkhart Apex electric valve controller provided on the pump operators panel with a second controller provided at the outlet. The electric control must be of a true position feedback design, requiring no clutches in the motor or current limiting. The controller will have momentary open, close as well as programmable preset valve positions. The controller will provide position indication on a full color, backlit LCD display. It will have manual adjustment of the brightness as well as an auto dimming option.

In addition to valve position, each controller will include a pressure display. 0566073
Elbow, Large Dia Outlet, 30 Deg,

4.00" FNST x 4.50" MNST

LARGE DIAMETER OUTLET ELBOWS
The

4.00 " outlet will be furnished with a

4.00 " (F) National Standard hose thread swivel x

4.50 "
(M) National Standard hose thread elbow adapter with cap. 0092572
Not Required, Outlet, Front

0516777
Outlet, Rear, 2.50", (1), Thru Tank,
PUC

REAR DISCHARGE OUTLET
There will be
One (
1 ) discharge outlet
piped to the rear of the hose bed on
left side
,installed so
proper clearance is provided for spanner wrenches or adapters. Plumbing will consist of

2.50 "
piping along with a

2.50 " full flow ball valve with the control from the pump operator's panel.

Discharge will terminate with

2.50 " NST thread. Discharge piping will be schedule
10 304
L
welded or formed stainless steel and routed through the water tank. 0045091
Elbow, Rear Outlets, 45 Degree,

2.50" FNST x 2.50" MNST, VLH

REAR OUTLET ELBOWS
The

2.50 " discharge outlets located at the rear of the apparatus will be furnished with a

2.50 " (F)
National Standard hose thread x

2.50 " (M) National Standard hose thread, chrome plated, 45 degree elbow.

The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0537394
Not Required, Outlet, Rear,
Additional, PUC

0537395
Not Required, Elbow, Rear Outlets,
Additional
0752097
Caps/Plugs for 1.00" to 3.00"
Discharges/Inlets, Chain

DISCHARGE CAPS/ INLET PLUGS
Chrome plated, rocker lug, caps with chain will be furnished for all discharge outlets

1.00 " thru

3.00 " in size, besides the pre-connected hose outlets.

Chrome plated, rocker lug, plugs with chain will be furnished for all auxiliary inlets

1.00 " thru

3.00 "
in size.

The caps and plugs will incorporate a thread design to automatically relieve stored pressure in the line when disconnected.
48 480
Bid #:

Page 487 of 665 ends

0723042
Valve, 0.75" Bleeder, Discharges, "T"
Swing Handle

OUTLET BLEEDER VALVE
A

0.75 " bleeder valve will be provided for each outlet

1.50 " or larger. Automatic drain valves are
acceptable with some outlets if deemed appropriate with the application.

The valves will be located behind the panel with a T swing style handle control extended to the outside of the side pump panel.

The handles will be chrome plated and provide a visual indication of valve position.

The T swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage.

Bleeders will be located at the bottom of the pump panel. They will be properly labeled identifying the discharge they are plumbed in to.

The water discharged by the bleeders will be routed below the chassis frame rails. 0516860
Outlet, 3.00" Deluge w/2.50" Valve,
PUC

DELUGE RISER
A

3.00 " deluge riser will be installed above the pump in such a manner that a monitor can be mounted and used effectively.

3.00 " piping will be installed securely so no movement develops when the line is charged. A

2.50 " gated valve will be installed and controlled at the pump operator's panel. The deluge outlet will flow a minimum 1000
GPM.
0095958
Deluge Outlet, Special
Height/Location

DELUGE OUTLET SPECIAL INSTRUCTIONS
The deluge gun outlet will be located
Off set the deluge

3.00 " to the drivers side to clear the hose
reel and allow full rotation of the monitor.
.
0543608
Monitor, Akron 3433 Hi-Riser and (2)

2.5" Inlet Grd Base

MONITOR
An Akron Model
3433
Apollo Hi-Riser monitor will be properly installed on the deluge riser. A fixed mounting base and a portable base with two (
2 )

2.50 " inlets will be provided.

A position sensor will be provided on the monitor that will activate the "do not move apparatus" light inside the cab when the monitor is in the raised position.

The monitor will be
painted as provided by monitor manufacturer
.
0046998
Nozzle, Elkhart SM-1250, Manual,
ST-194 Tips and 282A shaper

MONITOR NOZZLE
An Elkhart #SM-
1250
Select-O-Matic manual pattern control master stream nozzle will be provided.

Also included is an Elkhart ST-
194
Quad stack tips and
282
A shaper.
0005070
Deluge Mount, NPT

The deluge riser will have male National Pipe Threads for mounting the monitor. 0740360
SP
Crosslay Module, Std Width, Raised
Upper, Special Height,PUC

CROSSLAY MODULE
The crosslay module will be standard width.

The forward, upper corners of the module will have full body corners.

RAISED CROSSLAY
The upper section of crosslays will be raised from its standard height to allow a clear opening of

23.50 " in the lower crosslay. Raising the upper crosslay opening will increase the height of the lower crosslays.

The upper open section will shorten in height. If crosslays are required in this upper area, the hose capacity will determine the width.
0895041
SP
Hose Restraint, Crosslay, 1" Nylon
Web, Two Piece, Each Side, PUC

CROSSLAY HOSE RESTRAINT
There will be a two (
2 ) piece black
1 " nylon webbing design with a

2.00 " box pattern provided
across each end of the crosslay(s) to secure the hose during travel.

One (
1 ) piece will cover the upper crosslay openings and one ( 1 ) piece will cover the lower
crosslay opening.

Each restraint will be held in place with footman loops at the forward edge. Each restraint will have two (
2 ) seat belt buckles at the rearward edge. The female buckle will be attached to the restraint.
49 480
Bid #:

Page 488 of 665 ends

0750916
Crosslays, (2) 1.50", W/Poly Trays,
PUC

CROSSLAY(S), LOWER
There will be two (
2 ) lower crosslays provided.

1.50 " Crosslays
There will be two (
2 )

1.50 " crosslays plumbed with

2.00 " welded or formed schedule
10 304
L
stainless steel pipe.

The crosslays will be low mounted with the bottom of both crosslay trays no more than

11.00 "
above the frame rails for simple, safe reloading and deployment.

There will be a

1.50 " National Standard hose thread
90 -degree swivel provided in each hose bed,
so that the hose may be removed from either side of apparatus. The swivel will be as far outbound as possible for ease of changing hose.

Each crosslay will be gated with a

2.00 " quarter turn ball valve with the controls located at the pump operator's panel.

Each hose bed will be capable of carrying
200
' of

1.75 " double jacket hose
.

Crosslay Hose Trays
A removable tray will be provided for each crosslay hose bed. The crosslay tray will be constructed of black poly to provide a lightweight sturdy tray. Two ( 2 ) hand holes will be in the
floor and additional hand holes will be provided in the sides for easy removal and installation from the compartment. The floor of the trays will be perforated to allow for drainage and hose drying.

Trays will be held in place by a mechanical spring-loaded stainless-steel latch that automatically deploys upon loading the trays to hold the trays in place during transit. 0746380
Crosslay, (1) 1.50", W/Poly Trays,
PUC

CROSSLAY(S), UPPER
There will be one (
1 ) upper crosslays provided.

1.50 " Crosslays
There will be one (
1 )

1.50 " crosslays plumbed with

2.00 " welded or formed schedule
10 304
L
stainless steel pipe.

There will be a

1.50 " National Standard hose thread
90 -degree swivel provided in each hose bed,
so that the hose may be removed from either side of apparatus. The swivel will be as far outbound as possible for ease of changing hose.

Each crosslay will be gated with a

2.00 " quarter turn ball valve with the controls located at the pump operator's panel.

Each hose bed will be capable of carrying
200
' of

1.75 " double jacket hose
.

Crosslay Hose Trays
A removable tray will be provided for each crosslay hose bed. The crosslay tray will be constructed of black poly to provide a lightweight sturdy tray. Two ( 2 ) hand holes will be in the
floor and additional hand holes will be provided in the sides for easy removal and installation from the compartment. The floor of the trays will be perforated to allow for drainage and hose drying.

Trays will be held in place by a mechanical spring-loaded stainless-steel latch that automatically deploys upon loading the trays to hold the trays in place during transit. 0735116
SP
Storage, Long Tool, Adjus Partition,
Upper Crosslay Module, Door, PUC

LONG TOOL STORAGE
Storage will be provided for long tools in the upper crosslay module. The storage area will be enclosed and removable from either side of the truck. A vertically hinged aluminum treadplate

door with a
D-handle latch
will be provided on each end of the storage. The doors will be hinged along the rearward edge
. The area for storage of long tools will be
Ahead of the upper crosslay
and as wide as possible while still being able to open the door fully and remove backboard or long handle tool. Match previous Job
26797
in size.

There will be
One (
1 ) partition
vertically mounted in adjustable tracks installed
Ahead of the upper
crosslay. Match previous Job
26797
.
0015216
Reel, Booster, Aluminum - Over
Pump, Right Side

BOOSTER HOSE REEL
A Hannay electric rewind booster hose reel will be installed over the pump in a recessed open compartment on the right side of the apparatus. The reel will be fabricated of aluminum and have highly polished end discs.

A polished stainless steel roller and guide assembly will be mounted on the reel side of the apparatus.

Discharge control will be provided at the pump operator's panel. Plumbing to the reel will consist of

1.50 " Aeroquip hose and a

1.50 " valve.
0005281
Switch, Reel Rewind - Stirrup, 1
Reel/1 Switch
Reel motor will be protected from overload with an automatic reset circuit breaker.

One (
1 ) foot actuated, stirrup type, electric rewind control (switch) will be installed below the running board.
0005300
Hose, Booster - 150' of 1.00"/800 PSI
Booster hose,

1.00 " diameter and
150
feet, with chrome plated Barway, or equal couplings will be provided.

Working pressure of the booster hose will be a minimum of 800
psi.
0017858
Capacity, Hose Reel 150' of 1"

Capacity of the hose reel will be 150 feet of 1.00" booster hose. 0007428
Nozzle for Booster Reel Not Req'd

50 480
Bid #:

Page 489 of 665 ends

0085328
Nozzle Cup, Zico w/Bracket

NOZZLE CUP AND BRACKET
A Zico nozzle cup and chrome plated mounting bracket will be provided for storage of the booster reel nozzle.

There will be
one (
1 )
provided. The nozzle cup(s) will have a
3-1/2
" inside diameter
and will be
located
passenger side front body bulkhead
.
0676021
Foam Sys, Husky 3, Single Agent,
PUC, Multi Select Feature

HUSKY
3 FOAM PROPORTIONER
A Pierce Husky®
3 foam proportioning system will be provided. The Husky 3 is an on demand,
automatic proportioning, single point, direct injection system suitable for all types of Class A and B foam concentrates, including the high viscosity (
6000
cps), alcohol resistant Class B foams.

Operation will be based on direct measurement of water flow, and remain consistent within the specified flows and pressures. The system will automatically proportion foam solution at rates from

0.1 percent to
3 percent regardless of variations in water pressure and flow, up to the maximum rated capacity of the foam concentrate pump.

The design of the system will allow operation from draft, hydrant, or relay operation.

System Capacity
The system will have the ability to deliver the following minimum foam solution flow rates at accuracies that meet or exceed NFPA requirements at a pump rating of 150
psi.
100
gpm @
3 percent
300
gpm @
1 percent
600
gpm @

0.5 percent
Class A foam setting in

0.1 percent increments from

0.1 percent to
1 percent. Typical settings of
1 percent,

0.5 percent and

0.3 percent (maximum capacity will be limited to the plumbing and water pump capacity).

Control System
The system will be equipped with a digital electronic control display located on the pump operators panel. Push button controls will be integrated into the panel to turn the system on/off, control the foam percentage, and to set the operation modes.

The percent of injection will have a preset. This preset can be changed at the fire department as desired. The percent of injection will be able to be easily changed at the scene to adjust to changing demands.

Three (
3 )

0.50 " high LEDs will display the foam percentage in numeric characters. Three ( 3 )
indicator LEDs will also be included: one (
1 ) green, one (
1 ) red, and one (
1 ) yellow. The LEDs will
indicate various system operation or error states.

The indications will be:

Solid Green - System On
Solid Red - Valve Position Error
Solid Yellow - Priming System
Flashing Green - Injecting Foam
Flashing Red - Low Tank Level
Flashing Yellow - Refilling Tank
The control display will house a microprocessor, which receives input from the systems water flow meter while also monitoring the position of the foam concentrate pump. The microprocessor will compare the values of the water flow versus the position/rate of the foam pump, to ensure the proportion rate is accurate. One (
1 ) check valve will be installed in the plumbing to prevent foam from contaminating the water pump.

Hydraulic Drive System
The foam concentrate pump will be powered by an electric over hydraulic drive system. The hydraulic system and motor will be integrated into one unit.

Foam Concentrate Pump
The foam concentrate pump will be of positive displacement, self-priming; linear actuated design, driven by the hydraulic system. The pump will be constructed of brass body; chrome plated stainless steel shaft, with a stainless steel piston. In order to increase longevity of the pump, no aluminum will be present in its construction.

A relief system will be provided which is designed to protect the drive system components and prevent over pressuring the foam concentrate pump.

The foam concentrate pump will have minimum capacity for 3 gpm with all types of foam
concentrates with a viscosity at or below
6000
cps including protein, fluoroprotein, AFFF, FFFP,
or AR-AFFF. The system will deliver only the amount of foam concentrate flow required, without recirculating foam back to the storage tank. Recirculating foam concentrate back to the storage tank can cause agitation and premature foaming of the concentrate, which can result in system failure. The foam concentrate pump will be self-priming and have the ability to draw foam concentrate from external supplies such as drums or pails.

External Foam Concentrate Connection
An external foam pick-up will be provided to enable use of a foam agent that is not stored on the vehicle. The external foam pick-up will be designed to allow continued operation after the on- board foam tank is empty, or the use of foam different than the foam in the foam tank.

Panel Mounted External Pick-Up Connection / Valve
A bronze three (
3 )-way valve will be provided. The unit will be mounted to the pump panel. The valve unit will function as the foam system tank to pump valve and external suction valve. The external foam pick-up will be one (
1 )

0.75 " male connection GHT (garden hose thread) with a
cap.

Pick-Up Hose
A

0.75 " flexible hose with an end for insertion into foam containers will be provided. The hose will be supplied with a

0.75 " female swivel GHT (garden hose thread) swivel connector. The hose will be shipped loose.

Discharges
The foam system will be plumbed to the
lower rear crosslay, lower front crosslay, upper rear
crosslay and hose reel in the rear compartment
.

System Electrical Load
The maximum current draw of the electric motor and system will be no more than 55 amperes at
12 VDC.
51 480
Bid #:

Page 490 of 665 ends

0012126
Not Required, CAF Compressor

0592527
Refill, Foam Tank, Integral, Husky 3

SINGLE FOAM TANK REFILL
The foam system's proportioning pump will be used to fill the foam tank. This will allow use of the auxiliary foam pick-up to pump the foam from pails or a drum on the ground into the foam tank. A foam shut-off switch will be installed in the fill dome of the tank to shut the system down when the tank is full. The fill operation will be controlled by a mode in the foam system controller. While the proportioner pump is filling the tank, the controller will display a flashing yellow LED to indicate that the tank is filling. When the tank is full, as determined by the float switch in the tank dome, the pump will stop and the controller will shut the yellow LED off. If it attempted to use tank fill and the refill valve and suction valve are in the wrong position(s), then a red LED will illuminate to indicate the improper valve position(s). When the valves are positioned properly, then filling will commence.
0031896
Demonstration, Foam System, Dealer
Provided
0530519
Foam Cell, 30 Gallon, Not Reducing,
PUC

FOAM CELL
The foam cell will be an integral portion of the polypropylene water tank. The cell will have a capacity of
30 gallons of foam with the intended use of
Class A foam
. The brand of foam stored in
this tank will be
Phos-Chek
. The foam cell will not reduce the capacity of the water tank. The foam cell will have a screen in the fill dome and a breather in the lid. 0697589
Drain, 1.00", Foam Tank #1, Husky 3
Foam System, Quarter Turn

FOAM TANK DRAIN
The foam tank drain will be a

1.00 " quarter turn drain valve located inside the pump/plumbing compartment.
0091079
Not Required, Foam Tank #2

0091112
Not Required, Foam Tank #2 Drain

0746447
Approval Dwg, All Pump Panel(s),
Includes Color And Label Tags

The following drawing(s) will be provided for approval by the customer. The drawing(s) will be made for up
26797
apparatus and/or similar Pierce job number.

PUMP OPERATOR'S PANEL DRAWING
A detailed drawing to scale of the pump operator's panel will be provided for the customer to review. The drawing will include all of the gauges, controls, switching, etc.., located on the pump operator's panel. The customer will be allowed to make changes and/or mark-ups to this approval drawing. The fire apparatus manufacturer will make revisions (If needed) to the drawing per the customer changes and/or mark-ups as long as the changes are physically possible within a specific product line.

The finalized and signed customer approved pump operator's panel drawing will become part of the contract documents.

Due to the way drain(s), bleeder(s), operational/maintenance tag(s) and NFPA required warning tag(s) are placed on pump panel(s), these items will NOT be shown on any pump panel approval drawing(s). These item(s) will be placed on pump panel(s) at the fire apparatus manufacturer discretion.

REMAINING PUMP PANEL(S)
Detailed drawing(s) to scale of the remaining pump panel(s) will be provided for the customer to review. The drawing(s) will include all of the gauges, controls, switching, etc.., located on the pump panel(s). The customer will be allowed to make changes and/or mark-ups to these approval drawing(s). The fire apparatus manufacturer will make revisions (If needed) to the drawing(s) per the customer changes and/or mark-ups as long as the changes are physically possible within a specific product line.

The finalized and signed customer approved pump panel drawing(s) will become part of the contract documents.

Due to the way drain(s), bleeder(s), operational/maintenance tag(s) and NFPA required warning tag(s) are placed on pump panel(s), these items will NOT be shown on any pump panel approval drawing(s). These item(s) will be placed on pump panel(s) at the fire apparatus manufacturer discretion.

COLOR CODED TAGS
A detailed drawing/chart of the colors used on all of the inlet(s) and outlet(s) will be provided for the customer to review. The customer will be allowed to make changes and/or mark-ups to this approval drawing/chart. The fire apparatus manufacturer will make revisions (If needed) to the drawing per the customer changes and/or mark-ups as long as the changes are physically possible within a specific product line.

The finalized and signed customer approved drawing/chart of the colors will become part of the contract documents.

SPECIAL TEXT/VERBIAGE TAGS
A detailed drawing/chart of the text/verbiage used on all of the inlet(s) and outlet(s) will be provided for the customer to review. The customer will be allowed to make changes and/or mark- ups to this approval drawing/chart. The fire apparatus manufacturer will make revisions (If needed) to the drawing per the customer changes and/or mark-ups as long as the changes are physically possible within a specific product line.

The finalized and signed customer approved drawing/chart of the text/verbiage will become part of the contract documents.
52 480
Bid #:

Page 491 of 665 ends

0032479
Pump Panel Configuration, Control
Zone

PUMP PANEL CONFIGURATION
The pump panel configuration will be arranged and installed in an organized manner that will provide user-friendly operation.
0516975
Material, Pump Panels, Operators
Brushed Stainless, Sides Brushed
Stainless, PUC

PUMP AND GAUGE PANEL
The pump operator's panel and gauge panels will be constructed of stainless steel with a brushed finish.

The side control panels will be constructed of stainless steel with a brushed finish for durability and ease of maintenance.
0516978
Pump and Plumbing Access, Simple
Tilt Service, PUC

PUMP AND PLUMBING ACCESS
Simple access to the plumbing will be provided through the front of the body area by raising the cab for complete plumbing service and valve maintenance. Access to valves will not require removal of operator panels or pump panels. Access for rebuilding of the pump will not require removal of more than the tank to pump line and a single discharge line. This access will allow for fast, easy valve or pump rebuilding, making for reduced out of service times. Steps will be provided for access to the top of the pump.

Access to the pump will be provided by raising the cab. The pump will be positioned such that all maintenance and overhaul work can be performed above the frame and under the tilted cab. The service and overhaul work on the pump will not require the removal of operator panels or pump panels. Complete pump casing and gear case removal will require no more than removal of the intake and discharge manifolds, driveline, coolers and a single discharge line. The pump case and gear case will be able to be removed by lifting upward without interference from piping and be removable in less than
3 hours.
0520326
Light, Pump Compt, PUC

PUMP COMPARTMENT LIGHT
A pump compartment light will be provided inside the plumbing area.

A .
125
" weep hole will be provided in each light lens, preventing moisture retention. 0516983
Gauges, Engine, Included With
Pierce Pressure Controller, PUC

Engine monitoring graduated LED indicators will be incorporated with the pressure controller. 0005601
Throttle, Engine, Incl'd w/Press
Controller
0739224
Indicator Light @ Pump Panel,
Throttle Ready, Incl w/Pressure
Gov/Throttle,Green

THROTTLE READY GREEN INDICATOR LIGHT
There will be a green indicator light integrated with the pressure governor and/or engine throttle installed on the pump operators panel that is activated when the pump is in throttle ready mode. 0549333
Indicators, Engine, Included with
Pressure Controller
0005689
Gauges, 4.50" Master, Class 1, 30"-0
-600psi

VACUUM AND PRESSURE GAUGES
The pump vacuum and pressure gauges will be liquid filled and manufactured by Class 1 Incorporated ©.

The gauges will be a minimum of

4.50 " in diameter and will have white faces with black lettering, with a pressure range of

30.00 "-
0-600#
.

The pump pressure and vacuum gauges will be installed adjacent to each other at the pump operator's control panel.

Test port connections will be provided at the pump operator's panel. One will be connected to the intake side of the pump, and the other to the discharge manifold of the pump. They will have

0.25 in. standard pipe thread connections and polished stainless steel plugs. They will be marked with a label.
0511104
Gauge, 3.00" Pressure, Class 1, 30"-
0-400psi

PRESSURE GAUGES
The individual "line" pressure gauges for the discharges will be interlube filled and manufactured by Class
1 ©.

The gauges will be a minimum of

3.00 " in diameter and will have white faces with black lettering.

Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded retaining nut.

Gauges will have a pressure range of
30 "-
0-400#
.

The individual pressure gauge will be installed as close to the outlet control as practical.

This gauge will include a
10 year warranty against leakage, pointer defect, and defective bourdon tube.
53 480
Bid #:

Page 492 of 665 ends

0756688
Gauge, Water Level, Pierce, In
pressure Controller, w/Mini Slave,
PUC, Lt Driver

WATER LEVEL GAUGE
An electric water level gauge will be incorporated in the pressure controller that registers water level by means of nine (
9 ) LEDs. They will be at
1/8
level increments with a tank empty LED. The
LEDs will be a bright type that is readable in sunlight, and have a full 180
-degree of clear viewing.

To further alert the pump operator, the gauge will have a warning flash when the tank volume is less than
25 percent. The gauge will have down chasing LEDs when the tank is almost empty.

The level measurement will be ascertained by sensing the head pressure of the fluid in the tank or cell.

MINI SLAVE UNIT
An electric water level gauge will be provided in the cab that registers water level by means of five (
5 ) LEDs. They will be at
1/4
level increments with a tank empty LED. The LEDs will be a bright type that are readable in sunlight and have a full 180
-degree of clear viewing.

The water level gauge in the cab will be activated when the pump is in gear
.
0750438
Water Level Gauge, Wln PSTANK2,
LED 1-Light, 4-Level

WATER LEVEL GAUGE
There will be
two (
2 )
additional water level indicator(s), Whelen®, Model PSTANK 2 , LED module
with
chrome trim
, installed
one (
1 ) each side rearward of crew cab doors
.

This light module(s) will include four (
4 ) colored levels, and function similar to the water level indicator located at the operators panel:

First green module indicates a full water level
Second blue module indicates a water level above
3/4
full
Third amber module indicates a water level above
1/2
full
Last red module indicates a water level above
1/4
full and empty
Above
1/4
this light will be steady burning
At empty this light will be flashing
The flash rate will be determined by the main water level tank sensor.

This module will be activated when the
pump is in gear
.
0062992
Gauge, Foam Level, (1) Tank, Class
1, GAAAR 5lt

FOAM LEVEL GAUGE
An electronic foam level gauge will be provided on the operator's panel that registers foam level by means of five (
5 ) colored LED lights. The lights will be durable, ultra-bright five ( 5 ) LED design
viewable through
180
degrees. The foam level indicators will be as follows:
100
percent = Green
75 percent = Yellow
50 percent = Yellow
25 percent = Yellow
Refill = Red
The light will flash when the level drops below the given level indicator to provide an eighth of a tank indication. To further alert the pump operator, the lights will flash sequentially when the foam tank is empty.

The level measurement will be based on the sensing of head pressure of the fluid in the tank.

The display will be constructed of a solid plastic material with a chrome plated die cast bezel to reduce vibrations that can cause broken wires and loose electronic components. The encapsulated design will provide complete protection from foam and environmental elements. An industrial pressure transducer will be mounted to the outside of the tank. The display will be able to be calibrated in the field and will measure head pressure to accurately show the tank level. 0520243
Light, Pump Operator & Panel, Side
Ctrl, PUC, Incandescent

SIDE CONTROL PUMP OPERATOR'S/PUMP PANEL LIGHTING
Illumination will be provided for controls, switches, essential instructions, gauges, and instruments necessary for the operation of the apparatus and the equipment provided on it. External illumination will be a minimum of five (
5 ) foot-candles on the face of the device. Internal
illumination will be a minimum of four (
4 ) footlamberts.

The pump panels will be illuminated by a light on each side of the back of the cab.

The pump operator's panel will utilize strip lighting at the forward doorframe and an overhead light.
0606694
Air Horns, (2) Hadley, 6" Round,
eTone, In Bumper

AIR HORN SYSTEM
Two (
2 ) Hadley®, eTone, chrome air horns will be recessed in the front bumper. The air horn system will be piped to the air brake system wet tank utilizing

0.38 " tubing. A pressure protection
valve will be installed to prevent the loss of air in the brake system. 0606832
Location, Air Horns, Bumper, Left
Side, Outside Frame, Same Side
(Pos #6 & #7)
Air Horn Location
The air horns will be located on the left side of the bumper, outside of the frame rail. 0757092
Control, Air Horn, Multi Select

Air Horn Control
The air horn(s) will be activated by the following:
0757084
Control, Air Horn, Horn Ring

Steering wheel horn ring with electric/air horn selector switch 0723391
Control, Air Horn, Chrome Push
Button Sw, RS
Right side chrome push button switch
54 480
Bid #:

Page 493 of 665 ends

0006133
Siren, Code 3 3692 100W or 200W

ELECTRONIC SIREN
A Code
3 ®, Model
3692
, electronic siren with noise canceling microphone will be provided.

This siren to be active when the battery switch is on and the emergency master switch is on. 0557179
Location, Siren, Heavy Swivel Mount
Center Console, Not Overhead

Siren head will be located on a heavy duty swivel bracket mounted on the center console between the driver and officer seats, located
To be determined at pre-construction
. The swivel
bracket will be capable of rotating a minimum of 180 degrees. 0076156
Control, Elec Siren, Head Only
The electronic siren will be controlled on the siren head only. No horn button or foot switches will be provided.
0601398
Speaker, (1) Code 3, C3100 Series

SPEAKER
There will be one (
1 ) Code
3 ®, Model C
3100
speaker provided. The speaker will be
connected to
the siren amplifier
.
0601552
Location, Speaker, Frt Bumper,
Recessed, Right Side, Outside
Frame,Inbrd (Pos 2)
The speaker will be recessed in the right side of the front bumper, just outside of the frame rail. 0895281
Siren, Federal Q2B, Littelfuse 24213
Sol

AUXILIARY MECHANICAL SIREN
There will be a Federal Signal Model Q
2 B mechanical siren furnished and installed in the front of the apparatus.

The Q
2 B siren will be
chrome finish
.

The siren will have a
2 -gauge cable connected to a Littelfuse part number
24213
power solenoid
that is connected by a
2 -gauge cable ran battery direct to the primary chassis batteries and will be labeled Q
2 B+ at the battery. The power solenoid will only be enabled when the emergency master switch is on.

The siren will have a
2 -gauge ground wire connected to the chassis battery stud. The cable will be labeled Q
2 B- at the battery.
0006097
Location of Siren, Recessed in
Bumper
The mechanical siren will be recessed in the front bumper on the left side
. The siren will be
properly supported using the bumper framework.
0748305
Control, Mech Siren, Multi Select

MECHANICAL SIREN CONTROL
The mechanical siren will be activated by the following:
0748281
Control Mech Siren, Ft Sw RS

Right side foot switch.
0748282
Control Mech Siren, Ft Sw LS

Left side foot switch.
0740391
Sw, Siren Brake, Momentary Chrome
Push Button, RS
A momentary chrome push button switch will be included in the right side dash panel to activate the siren brake.
0023656
Grille, Speaker, Front Bumper,S/S

SPEAKER GRILLE
There will be
one (
1 )
grille provided over the speaker in the front bumper. The grille will be made of stainless steel.
0746353
Not Required, Warning Lights
Intensity
55 480
Bid #:

Page 494 of 665 ends

0751350
SP
Lightbar, Wln, Freedom IV-Q, 81",
RRRRRWsrROptRsrWRRRRR

FRONT ZONE UPPER WARNING LIGHTS
There will be one (
1 )

81.00 " Whelen® Freedom IV lightbar mounted on the cab roof.

The lightbar will include the following:

One (
1 ) red flashing LED module in the left side end position One (
1 ) red flashing LED module in the left side front corner position One (
1 ) red flashing LED module in the left side first front position One (
1 ) red flashing LED module in the left side second front position One (
1 ) red flashing LED module in the left side third front position One (
1 ) white flashing LED module in the left side fourth front position One (
1 ) red steady burning LED module in the left side fifth front position One (
1 ) red flashing LED module in the left side sixth front position.

One (
1 )
795
LED traffic light controller set to
national standard high priority
in the center positions.

One (
1 ) red flashing LED module in the right side sixth front position One (
1 ) red steady burning LED module in the right side fifth front position One (
1 ) white flashing LED module in the right side fourth front position One (
1 ) red flashing LED module in the right side third front position One (
1 ) red flashing LED module in the right side second front position One (
1 ) red flashing LED module in the right side first front position One (
1 ) red flashing LED module in the right side front corner position One (
1 ) red flashing LED module in the right side end position There will be
clear lenses included on the lightbar
.

The lightbar will be controlled per the following:

A switch installed in the cab on the switch panel to control the warning lights The traffic light controller
by a cab switch with emergency master control
.

Momentary activation by
an ignition powered momentary switch provided on the left side switch panels to momentarily activate the traffic light controller The white lights and the traffic light controller will be deactivated when the parking brake is applied
The eight (
8 ) red flashing LED modules in the front positions may be load managed when the parking brake is applied
0898734
Light, Front Zone, Wln M6** M6**
M6** M6** Q Bzl

CAB FACE WARNING LIGHTS
There will be four (
4 ) Whelen®, Model M
6 **,

4.31 " high x

6.75 " wide x

1.37 " deep flashing LED
warning lights installed on the cab face, above the headlights in a housing that matches the headlights per the following:

The
left side outside warning light to include blue LEDs
.

The
left side inside warning light to include red LEDs
.

The
right side inside warning light to include red LEDs
.

The
right side outside warning light to include red LEDs
.

The
warning light lens colors to be the same as the LEDs
.

The
housing to be polished and the trim shall be chrome
.

The lights will be controlled per the following:

A switch in the cab, on the switch panel will control the lights.

White LEDs will be deactivated when the parking brake is applied.

Amber LEDs will be deactivated when the parking brake is released.

Amber, blue, green or red LEDs in the inside positions may be load managed when the parking brake is applied.
0793476
Lights, Side Zone Lower, Wln M6**
LED, PUC, 2pr

SIDE ZONE LOWER LIGHTING
There will be four (
4 ) Whelen®, Model M
6 **,

4.31 " high x

6.75 " long x

1.37 " deep flashing LED
warning lights with chrome trim installed per the following:

Two (
2 ) lights,
one (
1 ) each side on the front custom cab corner
. The
side front warning LEDs to
be red
.

Two (
2 ) lights,
one (
1 ) each side above rear wheels
. The
side rear LEDs to be red
.

The
warning light lens colors to be the same as the LEDs
.

There will be a switch in the cab on the switch panel to control the lights. 0564655
Lights, Rear Zn Lwr, Wln M6*C LED,
Clear Lens, For Tail Lt Housing

REAR ZONE LOWER LIGHTING
There will be two (
2 ) Whelen®, Model M
6 *C, LED flashing warning lights located at the rear of the apparatus.

The
driver's side rear light to be red
The
passenger's side rear light to be red
Both lights will include a lens that is clear.

There will be a switch located in the cab on the switch panel to control the lights. 0535742
Mounting, Light, Recess in D/S Rear
Bulkhead, Each

MOUNTING, RECESS LIGHT
The upper rear warning light, on driver side rear bulkhead, will be recessed into the body. The lights will be flush to the compartment sheet.
0541116
Lights, Rear/Side Up Zone, Wln M6*
LED, Colored Lens 4lts
WARNING LIGHTS (Rear and Side upper zones)
Four (
4 ) Whelen, model M
6 * LED flashing warning lights will be provided at the rear of the apparatus with Whelen,
6 EFLANGE chrome flanges.

The
side rear upper light(s) on the driver's side to be red .

The
rear upper light(s) on the driver's side to be red
.

The
rear upper light(s) on the passenger's side to be red
.

The
side rear upper light(s) on the passenger's side to be red .

These lights will include a lens that is the same color as the LED's.

There will be a switch located in the cab on the switch panel to control the lights. 56 480
Bid #:

Page 495 of 665 ends

0006551
Not Required, Lights, Rear Upper
Zone Blocking
0590000
No Hose Bed Warn Light Brackets
Req'd, Lights Mtd on Hatch/Body
Compts, PUC
0023717
Electrical System, A/C w/Customer
Installed Generator
ELECTRICAL SYSTEM GENERAL DESIGN for ALTERNATING CURRENT The following guidelines will apply to the
120/240
VAC system installation:

General
Except where superseded by the requirements of NFPA
1901
, all components, equipment and
installation procedures will conform to NFPA
70 , National Electrical Code (herein referred to as
the NEC).

Line voltage electrical system equipment and materials included on the apparatus will be listed and installed in accordance with the manufacturer's instructions. All products will be used only in the manner for which they have been listed.

Grounding
An equipment grounding means will be provided in accordance with Section 250-62
(Grounding
Conductor Material) of the NEC.

The grounded current carrying conductor (neutral) will be insulated from the equipment grounding conductors and from the equipment enclosures and other grounded parts. The neutral conductor will be colored white or gray in accordance with Section 200-6
(Means of Identifying Grounding
Conductors) of the NEC.

In addition to the bonding required for the low voltage return current, each body and driving or crew compartment enclosure will be bonded to the vehicle frame by a copper conductor. This conductor will have a minimum amperage rating of
115
percent of the nameplate current rating of
the power source specification label as defined in Section 310-15
(amp capacities) of the NEC. A
single conductor, properly sized to meet the low voltage and line voltage requirements will be permitted to be used.

Wiring Methods
Fixed wiring systems will be limited to the following:
- Metallic or nonmetallic liquid tight flexible conduit rated at not less than 194
degrees Fahrenheit
(
90 degrees Celsius)
or
- Type SO or Type SEO cord with a WA suffix, rated at
600
volts at not less than
194
degrees
Fahrenheit (
90 degrees Celsius)
Electrical cord or conduit will not be attached to chassis suspension components, water or fuel lines, air or air brake lines, fire pump piping, hydraulic lines, exhaust system components, or low voltage wiring. In addition the wiring will be run as follows:
- Separated by a minimum of
12 inches (
305
mm), or properly shielded, from exhaust piping
- Separated from fuel lines by a minimum of six (
6 ) inches (
152
mm) distance.

Electrical cord or conduit will be supported within six ( 6 ) inches (
152
mm) of any junction box and
at a minimum of every
24 inches (
610
mm) of continuous run. Supports will be made of
nonmetallic materials or corrosion protected metal. All supports will be of a design that does not cut or abrade the conduit or cable and will be mechanically fastened to the vehicle.

Wiring Identification
All line voltage conductors located in the main panel board will be individually and permanently identified. The identification will reference the wiring schematic or indicate the final termination point. When prewiring for future power sources or devices, the unterminated ends will be labeled showing function and wire size.

Wet Locations
All wet location receptacle outlets and inlet devices, including those on hardwired remote power distribution boxes, will be of the grounding type provided with a wet location cover and installed in accordance with Section
210-7
"Receptacles and Cord Connections" of the NEC.

All receptacles located in a wet location will be not less than 24 inches (
610
mm) from the
ground. Receptacles on off-road vehicles will be a minimum of 30 inches (
762
mm) from the
ground.

The face of any wet location receptacle will be installed in a plane from vertical to not more than 45 degrees off vertical. No receptacle will be installed in a face up position.

Dry Locations
All receptacles located in a dry location will be of the grounding type. Receptacles will be not less than
30 inches (
762
mm) above the interior floor height.

All receptacles will be marked with the type of line voltage ( 120
-volts or
240
-volts) and the current
rating in amps. If the receptacles are direct current, or other than single phase, they will be so marked.

Listing
All receptacles and electrical inlet devices will be listed to UL 498
, Standard for Safety
Attachment Plugs and Receptacles, or other appropriate performance standards. Receptacles used for direct current voltages will be rated for the appropriate service.

Electrical System Testing
The wiring and associated equipment will be tested by the apparatus manufacturer or the installer of the line voltage system.

The wiring and permanently connected devices and equipment will be subjected to a dielectric voltage withstand test of
900
volts for one (
1 ) minute. The test will be conducted between live
parts and the neutral conductor, and between live parts and the vehicle frame with any switches in the circuit(s) closed. This test will be conducted after all body work has been completed.

Electrical polarity verification will be made of all permanently wired equipment and receptacles to determine that connections have been properly made.
57 480
Bid #:

Page 496 of 665 ends

0809082
SP
Wiring And Mounting Provisions,
Honda EM6500 SXKI - Gas, Over
Pump Location

PROVISIONS FOR GENERATOR
Provisions will be provided for the customer to install a generator. The generator will be a Honda, Model EM
6500
SXKI, gas powered portable generator.

All necessary wiring will be properly installed and structure provided to mount the generator above the pump, permanently.

The generator has the following characteristics:

Weight
227
pounds
Fuel Requirements
The generator will have its own

6.6 gallon fuel tank.

Exhaust
The muffler will be part of the generator.

Type of Cooling System
There will be a natural airflow over the generator.

Operating Criteria
The generator will be permanently mounted over the pump. 0010738
Mounting, Gas Generator Above
Pump w/Quick Release Brackets

GENERATOR LOCATION
The generator will be mounted in a recessed open compartment above the fire pump on the Driver side dunnage area along side hatch compartment (Match Job # 26797
)
. The oil drain and
oil dipstick for the generator will be accessible for maintenance. Generator will be mounted with quick release style mounting brackets.
0006750
Electric Start, Generator

ELECTRIC START PROVISION
Electric start provisions will be furnished for the generator from the chassis battery system. 0006755
Remote Start, Gas Generator

GENERATOR REMOTE START
A start/stop switch with indicator light will be provided on the pump panel
in addition to the
controls on the generator. The light is provided to indicate that the generator is running. 0016740
Not Required, Fuel System
0016767
Not Required, Oil Drain Extension,
Generator
0006737
Circuit Breaker Panel w/Cust or
Dealer Furn Generator

CIRCUIT BREAKER PANEL
A circuit breaker panel will be installed in the
CB Panel - on the back wall at the upper front
corner of the compartment over the rear axle on the driver side (Match Job 26797
)
. A directory for
each breaker will be provided adjacent to the circuit breaker panel. Identification of circuits will be done in a durable manner that provides years of service.

This breaker panel will be connected to
Honda EM
6500
SXKI
generator.
0016771
Not Required, Routing Exhaust,
Generator
0763926
SP
Light Twr, W-B Chf NS1.8-600 WHL,
4-P*H2 12VDC Lts Cld 6'

LIGHT TOWER
There will be one (
1 ) Will-Burt, Model NS

1.8-600
WHL light tower provided.

There will be four (
4 ) Whelen Model P*H
2 ,
150
watt,
12 volt DC white LED light heads included
on this tower.

The tower will come
with a combination of flood and spot optics
lights.

The painted parts of the light tower and light heads to be painted parts of the light tower and the
light heads to be white
.

This tower will be connected to the Do Not Move Truck Indicator in the cab.

The lights on this tower may be load managed when the parking brake is applied. 0664472
Location, Light Tower, Crew Cab
Roof
Light Tower Location
The light tower will be installed on the crew cab roof. 0617750
Controller, Lt Twr, W-B, Wired
Hndhld, E-STOP Chf, Chf Pr, Pow Pr

Light Tower Controller
There will be one (
1 ) handheld wired controller included.
0664791
Location, Light Tower Controller,
Driver's Side Front Body
Compartment
Light Tower Controller Location
The light tower controller will be installed in the driver's side front body compartment. 58 480
Bid #:

Page 497 of 665 ends

0006825
Reel, Elect Cable, Hannay, 1600, (3)
Wire

ELECTRIC CORD REEL
Furnished with the
120
volt AC electrical system will be a Hannay, Series
1600
, cord reel. The
reel will be provided with a
12 -volt electric rewind switch, that is guarded to prevent accidental operation and labeled for its intended use. The switch will be protected with a fuse and installed at a height not to exceed

72.00 " above the operators standing position.

The exterior finish of the reel(s) will be
painted
#269
gray from the reel manufacturer
.

A captive roller assembly to be provided to aid in the payout and loading of the reel . A ball stop
will be provided to prevent the cord from being wound on the reel.

A label will be provided in a readily visible location adjacent to the reel. The label will indicate current rating, current type, phase, voltage and total cable length.

A total of
one (
1 ) cord reel
will be provided
one (
1 ) in compartment LS
1 high and left
.

The cord reel will be configured with three (
3 ) conductors.
0006828
Cord, Electric, 10/3 Yellow, 3 Wire

CORD
Provided for electric distribution will be
one (
1 ) length installed on the reel
of
200
feet
of yellow
10/3
electrical cord, weather resistant
105
degree Celsius to -
50 degree Celsius,
600
volt
jacketed SOOW cord.

A Hubbell L
5-30
,
30 amp,
120
volt, twist lock connector body
will be
installed on the end of the cord.
0788933
Box, Junc, Akron, 3Wire, 2-15/20A
120V Dup SB, 2-20A 120V TL

PORTABLE JUNCTION BOX
There will be
one (
1 )
Akron EJBX electric junction box(es) provided.

There will be a cable strain relief and
a

1.00 ' pigtail with black plastic ribbed grip, NEMA L
5-20
,
20 amp,
120
volt twist lock plug
provided for each box.

Each box will be provided with the following:
two (
2 )
15/20
amp
120
volt AC duplex straight blade receptacle with flip up covers two (
2 )
20 amp
120
volt AC twist lock single receptacles with flip up covers a
120
volt AC light inside the box
0778560
Receptacle, 15A 120V 3-Pr 3-Wr TL,
Wtrprfroof
120

VOLT RECEPTACLE
There will be
three (
3 )
,
15 amp
120
volt AC three (
3 ) wire twist lock receptacle(s) with flip up cover
(s) installed
One (
1 ) - Fender well behind the rear axle, passengers side (Match job # 26797
) One
(
1 ) - Fender well behind the rear axle, drivers side. (Match job # 26797
) One (
1 ) To be defined at
pre-construction
. The NEMA configuration for the receptacles will be L
5-15
R.

The receptacle(s) will be powered from the
on board generator
.

There will be a label installed near the receptacle(s) that state the following:

Line Voltage
Current Ratting (amps)
Phase
Frequency
0519934
Not Required, Brand, Hydraulic Tool
System
0649753
Not Required, PTO Driven Hydraulic
Tool System
0007150
Bag of Nuts and Bolts

LOOSE EQUIPMENT
The following equipment will be furnished with the completed unit:

One (
1 ) bag
of chrome, stainless steel, or cadmium plated screws, nuts, bolts and washers, as used in the construction of the unit.
59 480
Bid #:

Page 498 of 665 ends

0602516
NFPA Required Loose Equipment,
Pumper, NFPA 2016, Provided by
Fire Department

NFPA REQUIRED LOOSE EQUIPMENT PROVIDED BY FIRE DEPARTMENT The following loose equipment as outlined in NFPA
1901
,
2016
edition, section

5.9.3 and

5.9.4 will be provided by the fire department.
800
ft (
60 m) of

2.50 " (
65 mm) or larger fire hose.
400
ft (
120
m) of

1.50 " (
38 mm),

1.75 " (
45 mm), or

2.00 " (
52 mm) fire hose.

One (
1 ) handline nozzle,
200
gpm (
750
L/min) minimum.

Two (
2 ) handline nozzles,
95 gpm (
360
L/min) minimum.

One (
1 ) smoothbore of combination nozzle with

2.50 " shutoff that flows a minimum of
250
gpm.

One (
1 ) SCBA complying with NFPA
1981
for each assigned seating position, but not fewer than
four (
4 ), mounted in brackets fastened to the apparatus or stored in containers supplied by the SCBA manufacturer.

One (
1 ) spare SCBA cylinder for each SCBA carried, each mounted in a bracket fastened to the apparatus or stored in a specially designed storage space(s).

One (
1 ) first aid kit.

Four (
4 ) combination spanner wrenches.

Two (
2 ) hydrant wrenches.

One (
1 ) double female

2.50 " (
65 mm) adapter with National Hose threads.

One (
1 ) double male

2.50 " (
65 mm) adapter with National Hose threads.

One (
1 ) rubber mallet, for use on suction hose connections.

Two (
2 ) salvage covers each a minimum size of
12 ft x
14 ft (

3.7 m x

4.3 m).

One (
1 ) traffic vest for each seating position, each vest to comply with ANSI/ISEA 207
,
Standard
for High Visibility Public Safety Vests
, and have a five-point breakaway feature that includes two (
2 ) at the shoulders, two (
2 ) at the sides, and one (
1 ) at the front.

Five (
5 ) fluorescent orange traffic cones not less than

28.00 " (
711
mm) in height, each equipped
with a

6.00 " (
152
mm) retro-reflective white band no more than

4.00 " (
152
mm) from the top of
the cone, and an additional

4.00 " (
102
mm) retro-reflective white band

2.00 " (
51 mm) below the

6.00 " (
152
mm) band.

Five (
5 ) illuminated warning devices such as highway flares, unless the five ( 5 ) fluorescent
orange traffic cones have illuminating capabilities.

One (
1 ) automatic external defibrillator (AED).

Four (
4 ) ladder belts meeting the requirements of NFPA
1983
,
Standard on Fire Service
Life
Safety Rope and System Components
(if equipped with an aerial device).

If the supply hose carried does not use sexless couplings, an additional double female adapter and double male adapter, sized to fit the supply hose carried, will be carried mounted in brackets fastened to the apparatus.

If none of the pump intakes are valved, a hose appliance that is equipped with one or more gated intakes with female swivel connection(s) compatible with the supply hose used on one side and a swivel connection with pump intake threads on the other side will be carried. Any intake connection larger than

3.00 " (
75 mm) will include a pressure relief device that meets the requirements of

16.6.6 .

If the apparatus does not have a

2.50 " National Hose (NH) intake, an adapter from

2.50 " NH
female to a pump intake will be carried, mounted in a bracket fastened to the apparatus if not already mounted directly to the intake.

If the supply hose carried has other than

2.50 " National Hose (NH) threads, adapters will be
carried to allow feeding the supply hose from a

2.50 " NH thread male discharge and to allow the
hose to connect to a

2.50 " NH female intake, mounted in brackets fastened to the apparatus if not already mounted directly to the discharge or intake.
0602407
Soft Suction Hose, Provided by Fire
Department, Pumper NFPA 2016
Classification

SOFT SUCTION HOSE PROVIDED BY FIRE DEPARTMENT
NFPA
1901
,
2016
edition, section

5.8.2.1 requires a minimum of
20 ' of suction hose or
15 ' of
supply hose will be carried.

Hose is not on the apparatus as manufactured. The fire department will provide suction or supply hose.
0027023
No Strainer Required
0602538
Extinguisher, Dry Chemical, Pumper
NFPA 2016 Class, Provided by Fire
Department

DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
NFPA
1901
,
2016
edition, section

5.9.4 requires one (
1 ) approved dry chemical portable fire
extinguisher with a minimum
80 -B:C rating mounted in a bracket fastened to the apparatus.

The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0602360
Extinguisher, 2.5 Gal. Pressurized
Water, Pumper NFPA 2016,Provided
by Fire Dept

WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
NFPA
1901
,
2016
edition, section

5.9.4 requires one (
1 )

2.5 gallon or larger water extinguisher
mounted in a bracket fastened to the apparatus.

The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0602679
Axe, Flathead, Pumper NFPA 2016
Classification, Provided by Fire
Department

FLATHEAD AXE PROVIDED BY FIRE DEPARTMENT
NFPA
1901
,
2016
edition, Section

5.9.4 requires one (
1 ) flathead axe mounted in a bracket
fastened to the apparatus.

The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe.
60 480
Bid #:

Page 499 of 665 ends

0602667
Axe, Pickhead, Pumper NFPA 2016
Classification, Provided by Fire
Department

PICKHEAD AXE PROVIDED BY FIRE DEPARTMENT
NFPA
1901
,
2016
edition, Section

5.9.4 requires one (
1 ) pickhead axe mounted in a bracket
fastened to the apparatus.

The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe.
0741569
Paint Process / Environmental
Requirements, Appleton

PAINT PROCESS
The exterior custom cab and body painting procedure will consist of a seven ( 7 ) step finishing
process as follows:

Manual Surface Preparation
- All exposed metal surfaces on the custom cab and body will be thoroughly cleaned and prepared for painting. Imperfections on the exterior surfaces will be removed and sanded to a smooth finish. Exterior seams will be sealed before painting. Exterior surfaces that will not be painted include; chrome plating, polished stainless steel, anodized aluminum and bright aluminum treadplate.

Chemical Cleaning and Pretreatment
- All surfaces will be chemically cleaned to remove dirt, oil, grease, and metal oxides to ensure the subsequent coatings bond well. The aluminum surfaces will be properly cleaned and treated using a high pressure, high temperature 4 step Acid Etch
process. The steel and stainless surfaces will be properly cleaned and treated using a high temperature
3 step process specifically designed for steel or stainless. The chemical treatment converts the metal surface to a passive condition to help prevent corrosion.

Surfacer Primer
- The Surfacer Primer will be applied to a chemically treated metal surface to provide a strong corrosion protective basecoat. A minimum thickness of 2 mils of Surfacer Primer
is applied to surfaces that require a Critical aesthetic finish. The Surfacer Primer is a two- component high solids urethane that has excellent sanding properties and an extra smooth finish when sanded.

Finish Sanding
- The Surfacer Primer will be sanded with a fine grit abrasive to achieve an ultra- smooth finish. This sanding process is critical to produce the smooth mirror like finish in the topcoat.

Sealer Primer
- The Sealer Primer is applied prior to the Basecoat in all areas that have not been previously primed with the Surfacer Primer. The Sealer Primer is a two-component high solids urethane that goes on smooth and provides excellent gloss hold out when topcoated.

Base
coat Paint
- Two coats of a high performance, two component high solids polyurethane basecoat will be applied. The Basecoat will be applied to a thickness that will achieve the proper color match. The Basecoat will be used in conjunction with a urethane clear coat to provide protection from the environment.

Clear Coat
- Two (
2 ) coats of Clear Coat will be applied over the Basecoat color. The Clear Coat is a two-component high solids urethane that provides superior gloss and durability to the exterior surfaces. Lap style and roll-up doors will be Clear Coated to match the body. Paint warranty for the roll-up doors will be provided by the roll-up door manufacturer.

After the cab and body are painted, the color will be verified to make sure that it matches the color standard. Electronic color measuring equipment will be used to compare the color sample to the color standard entered into the computer. Color specifications will be used to determine the color match. A Delta E reading will be used to determine a good color match within each family color.

All removable items such as brackets, compartment doors, door hinges, and trim will be removed and painted separately if required, to ensure paint behind all mounted items. Body assemblies that cannot be finish painted after assembly will be finish painted before assembly.

The paint finish quality levels for critical areas of the apparatus (cab front and sides, body sides and doors, and boom lettering panels) are to meet or exceed Cadillac/General Motors GMW
15777
global paint requirements. Orange peel levels are to meet or exceed the #6

A.C.T.standard in critical areas. The manufacture's written paint standards will be available upon request.

Environmental Impact
Contractor will meet or exceed all current state regulations concerning paint operations. Pollution control will include measures to protect the atmosphere, water and soil. Controls will include the following conditions:

Topcoats and primers will be chrome and lead free.

Metal treatment chemicals will be chrome free. The wastewater generated in the metal treatment process will be treated on-site to remove any other heavy metals.

Particulate emission collection from sanding operations will have a

99.99 percent efficiency
factor.

Particulate emissions from painting operations will be collected by a dry filter or water wash process. If the dry filter is used, it will have an efficiency rating of 98 percent. Water wash
systems will be

99.97 percent efficient
Water from water wash booths will be reused. Solids will be removed on a continual basis to keep the water clean.

Paint wastes are disposed of in an environmentally safe manner.

Empty metal paint containers will be recycled to recover the metal.

Solvents used in clean-up operations will be recycled on-site or sent off-site for distillation and returned for reuse.

Additionally, the finished apparatus will not be manufactured with or contain products that have ozone depleting substances. Contractor will, upon demand, present evidence that the manufacturing facility meets the above conditions and that it is in compliance with his state EPA rules and regulations.
0709763
Paint, Single Color, Velocity/Impel

CAB PAINT
The cab will be painted
#90
red
.
0709845
Paint, Single Color, Body

BODY PAINT
The body will be
painted to match the single cab paint color
.
61 480
Bid #:

Page 500 of 665 ends

0640911
Paint Chassis Frame Assy, E-Coat,
All Joints Sealed

PAINT/SEAL CHASSIS FRAME ASSEMBLY
The following components will be treated with epoxy E-coat protection prior to finish paint:

Two (
2 ) C-channel frame rails
The E-coat process will meet the technical properties shown.

Before the frame rails are finish painted, all areas will be sealed with a 3 M
2084
metal sealant
after the components are torqued to the frame rails:
- The joint between all crossmembers and the frame
- The joint between all spring hangers and the frame.

The chassis frame assembly will be finished with
a single system black top coat
before the
installation of the cab and body, and before installation of the engine and transmission assembly, air brake lines, electrical wire harnesses, etc.

Components that are included with the chassis frame assembly that will be finish painted are:

Frame rails
Cross membersAxles
Suspensions
Steering gear
Battery boxes
Bumper extension weldment
Frame extensions
Body mounting angles
Rear Body support substructure (front and rear)
Pump house substructure
Air tanks
Steel fuel tank
Castings
Individual piece parts used in chassis and body assembly After the chassis frame assembly is finish painted, the following non-torqued joints will be sealed with a SG-
510
A rust-proofing compound:
-All bolted on chassis components that could be vulnerable to rust, i.e. body mounting angles, air tanks, etc.

To summarize, all metal to metal contact components that are prone to rust, will be protected. 0693797
No Paint Required, Aluminum Front
Wheels

0693792
No Paint Required, Aluminum Rear
Wheels

0733739
Paint, Axle Hubs

AXLE HUB PAINT
All axle hubs will be painted
to match lower job color
.
0007230
Compartment, Painted, Spatter Gray

COMPARTMENT INTERIOR PAINT
The interior of all compartments will be painted with a gray spatter finish for ease of cleaning and to make it easier to touch up scratches and nicks.
0544129
Reflective Band, 1"-6"-1"

REFLECTIVE STRIPES
Three (
3 ) reflective stripes will be provided across the front of the vehicle and along the sides of the body. The reflective band will consist of a

1.00 "
white
stripe at the top with a

1.00 " gap then a

6.00 "
white
stripe with a

1.00 " gap and a

1.00 "
white
stripe on the bottom.
0510041
Reflective across Cab Face, Imp/Vel

The reflective band provided on the cab face will be below the headlights on the fiberglass. 0593732
Stripe, Chevron, Rear, Diamond
Grade, Pumper, PUC

REAR CHEVRON STRIPING
There will be alternating chevron striping located on the rear-facing vertical surface of the apparatus. The rear surface, excluding the rear roll up door, will be covered.

The colors will be red and
fluorescent yellow green
diamond grade.

Each stripe will be

6.00 " in width.

This will meet the requirements of the current edition of NFPA 1901
, which states that
50%
of the
rear surface will be covered with chevron striping.
0027341
Jog, In Reflective Stripe, Single or
Multiple

JOG(S) IN REFLECTIVE BAND
The reflective band located on each side of the apparatus body will contain one (
1 )
jog(s) and will
be angled at approximately a
45 degrees when installed.
0065687
Stripe, Reflective, Cab Doors Interior

CAB DOOR REFLECTIVE STRIPE
A

6.00 " x

16.00 "
white
reflective stripe will be provided across the interior of each cab door. The stripe will be located approximately

1.00 " up from the bottom, on the door panel.

This stripe will meet the NFPA
1901
requirement.
0027372
Lettering Specifications, (GOLD
STAR Process)

LETTERING
The lettering will be totally encapsulated between two ( 2 ) layers of clear vinyl.
62 480
Bid #:

Page 501 of 665 ends

0685693
Lettering, Printed Effect Gold Leaf,

3.00", Each

LETTERING
There will be printed effect gold leaf lettering,

3.00 " high, with
outline and shade
provided. There
will be
16 letters
provided.
0685540
Lettering, Printed Effect Gold Leaf,

9.00", Each

LETTERING
There will be printed effect gold leaf lettering,

9.00 " high, with
outline and shade
provided. There
will be
26 letters
provided.
0685548
Lettering, Printed Effect Gold Leaf,

7.00", Each

LETTERING
There will be printed effect gold leaf lettering,

7.00 " high, with
outline and shade
provided. There
will be
four (
4 ) letters
provided.
0685558
Lettering, Printed Effect Gold Leaf,

5.00", (21-40)

LETTERING
Twenty-one (
21 ) to forty (
40 ) printed effect gold leaf lettering,

5.00 " high, with
outline and
shade
will be provided.
0685589
Lettering, Printed Effect Gold Leaf,

4.00", (21-40)

LETTERING
Twenty-one (
21 ) to forty (
40 ) printed effect gold leaf lettering,

4.00 " high, with
outline and
shade
will be provided.
0655896
Sign Kit, Painted, Holder and Insert,
Each

SIGN KIT FOR LETTERING/NUMERALS
four (
4 )
painted stainless steel plate(s) and holder(s) will be provided for department lettering.

They will be mounted
crew cab door above the Scotchlite stripe per signed drawing with two ( 2 )
installed per unit and two (
2 ) shipped loose per unit.
26797-01
to say "E
1 " on two (
2 ) palacards
and "E
201
" on two (
2 ) placards.
26797-02
to say "E
2 " on two (
2 ) placards and "E
202
"
and
10 " x
14 '
in size.
0772003
Manual, Fire Apparatus Parts, USB
Flash Drive, Custom

FIRE APPARATUS PARTS MANUAL
There will be
one (
1 )
custom parts manual(s) in USB flash drive format for the complete fire apparatus provided.

The manual(s) will contain the following:

Job number
Part numbers with full descriptions
Table of contents
Parts section sorted in functional groups reflecting a major system, component, or assembly Parts section sorted in alphabetical order
Instructions on how to locate parts
Each manual will be specifically written for the chassis and body model being purchased. It will not be a generic manual for a multitude of different chassis and bodies.

Service Parts Internet Site
The service parts information included in these manuals are also available on the Pierce website.

The website offers additional functions and features not contained in this manual, such as digital photographs and line drawings of select items. The website also features electronic search tools to assist in locating parts quickly.
0772037
Manual, Chassis Service, USB Flash
Drive, Custom

CHASSIS SERVICE MANUALS
There will be
one (
1 )
chassis service manuals on USB flash drives containing parts and service information on major components provided with the completed unit.

The manual will contain the following sections:

Job number
Table of contents
Troubleshooting
Front Axle/Suspension
Brakes
Engine
Tires
Wheels
Cab
Electrical, DC
Air Systems
Plumbing
Appendix
The manual will be specifically written for the chassis model being purchased. It will not be a generic manual for a multitude of different chassis and bodies. 0773381
Manual, Chassis Operation, (1) USB
Flash Drive, Custom

CHASSIS OPERATION MANUAL
The chassis operation manual will be provided on one (
1 ) USB flash drive.
0030008
Warranty, Basic, 1 Year, Apparatus,
WA0008
ONE (
1 ) YEAR MATERIAL AND WORKMANSHIP
A Pierce basic apparatus limited warranty certificate, WA 0008
, is included with this proposal.
63 480
Bid #:

Page 502 of 665 ends

0611136
Warranty, Chassis, 3 Year,
Velocity/Impel, WA0284

THREE (
3 ) YEAR MATERIAL AND WORKMANSHIP
The Pierce custom chassis limited warranty certificate, WA 0284
, is included with this proposal.
0696698
Warranty, Engine, Cummins, 5 Year,
WA0181

ENGINE WARRANTY
A Cummins
five (
5 ) year
limited engine warranty will be provided. A limited warranty certificate, WA
0181
, is included with this proposal.
0684953
Warranty, Steering Gear, Sheppard
M110, 3 Year WA0201

STEERING GEAR WARRANTY
A Sheppard
three (
3 ) year
limited steering gear warranty will be provided. A copy of the warranty certificate will be submitted with the bid package.
0595767
Warranty, Frame, 50 Year,
Velocity/Impel, WA0038

FIFTY (
50 ) YEAR STRUCTURAL INTEGRITY
The Pierce custom chassis frame and crossmembers limited warranty certificate, WA 0038
, is
included with this proposal.
0595698
Warranty, Axle, 3 Year, TAK-4,
WA0050

FRONT AXLE THREE (
3 ) YEAR MATERIAL AND WORKMANSHIP WARRANTY
The Pierce TAK-
4 suspension limited warranty certificate, WA
0050
, is included with this proposal.
0733306
Warranty, Single Axle, 5 Year,
Meritor, General Service, WA0384

SINGLE REAR AXLE FIVE (
5 ) YEAR MATERIAL AND WORKMANSHIP WARRANTY
A Meritor
™
Axle
5 year limited warranty will be provided.
0652758
Warranty, ABS Brake System, 3
Year, Meritor Wabco, WA0232

ABS BRAKE SYSTEM THREE (
3 ) YEAR MATERIAL AND WORKMANSHIP

WARRANTY
A Meritor Wabco
™
ABS brake system limited warranty certificate, WA
0232
, is included with this
proposal.
0019914
Warranty, Structure, 10 Year, Custom
Cab, WA0012
TEN (
10 ) YEAR STRUCTURAL INTEGRITY
The Pierce custom cab limited warranty certificate, WA
0012
, is included with this proposal.
0744240
Warranty, Paint, 10 Year, Cab, Pro-
Rate, WA0055
TEN (
10 ) YEAR PRO-RATED PAINT AND CORROSION
A Pierce cab limited pro-rated paint warranty certificate, WA 0055
, is included with this proposal.
0524627
Warranty, Electronics, 5 Year, MUX,
WA0014
FIVE (
5 ) YEAR MATERIAL AND WORKMANSHIP
The Pierce Command Zone electronics limited warranty certificate, WA 0014
, is included with this
proposal.
0695416
Warranty, Pierce Camera System,
WA0188

CAMERA SYSTEM WARRANTY
A Pierce fifty four (
54 ) month
warranty will be provided for the camera system
.
0647720
Warranty, Pierce LED Strip Lights,
WA0203

COMPARTMENT LIGHT WARRANTY
The Pierce
12 volt DC LED strip lights limited warranty certificate, WA 0203
, is included with this
proposal.
0046369
Warranty, 5-year EVS Transmission,
Standard Custom, WA0187

TRANSMISSION WARRANTY
The transmission will have a
five (
5 ) year/unlimited mileage
warranty covering
100
percent
parts and labor. The warranty will be provided by Allison Transmission.

Note: The transmission cooler is not covered under any extended warranty you may be getting on your Allison Transmission. Please review your Allison Transmission warranty for coverage limitations.
0685945
Warranty, Transmission Cooler,
WA0216

TRANSMISSION COOLER WARRANTY
The transmission cooler will carry a five (
5 ) year parts and labor warranty (exclusive to the
transmission cooler). In addition, a collateral damage warranty will also be in effect for the first three (
3 ) years of the warranty coverage and will not exceed
$10,000
per occurrence. A copy of
the warranty certificate will be submitted with the bid package. 0688798
Warranty, Water Tank, Lifetime, UPF,
Poly Tank, WA0195

WATER TANK WARRANTY
A UPF poly water tank limited warranty certificate, WA
0195
, is included with this proposal.
0596025
Warranty, Structure, 10 Year, Body,
WA0009
TEN (
10 ) YEAR STRUCTURAL INTEGRITY
The Pierce apparatus body limited warranty certificate, WA 0009
, is included with this proposal.
64 480
Bid #:

Page 503 of 665 ends

0693127
Warranty, Gortite, Roll-up Door, 6
Year, WA0190

ROLL UP DOOR MATERIAL AND WORKMANSHIP WARRANTY
A Gortite roll-up door limited warranty will be provided. The mechanical components of the roll-up door will be warranted against defects in material and workmanship for the lifetime of the vehicle.

A
six (
6 ) year
limited warranty will be provided on painted and satin roll up doors.

The limited warranty certificate, WA
0190
, is included with this proposal.
0889364
Warranty, Pump, Pierce, PUC-NG, 7
Year Parts, 1 Year Labor, WA0390

SEVEN (
7 ) YEAR PARTS, ONE (
1 ) YEAR LABOR
The pump and its components will be provided with a seven ( 7 ) year parts and one (
1 ) year labor
limited warranty. The manufacturer's warranty will provide that the pump and its components will be free from failures caused by defects in material and workmanship that would arise under normal use and service.

A copy of the warranty certificate will be submitted with the bid package. 0648675
Warranty, 10 Year S/S Pumbing,
WA0035
TEN (
10 ) YEAR PUMP PLUMBING WARRANTY
The Pierce apparatus plumbing limited warranty certificate, WA 0035
, is included with this
proposal.
0657990
Warranty, Foam System, Husky 3,
WA0231

FOAM SYSTEM WARRANTY
The Husky
3 foam system limited warranty certificate, WA
0231
, is included with this proposal.
0595820
Warranty, Paint, 10 Year, Body, Pro-
Rate, WA0057
TEN (
10 ) YEAR PRO-RATED PAINT AND CORROSION
A Pierce body limited pro-rated paint warranty certificate, WA 0057
, is included with this proposal.
0595421
Warranty, Goldstar, 3 Year,
Apparatus, WA0018

THREE (
3 ) YEAR MATERIAL AND WORKMANSHIP
The Pierce Goldstar gold leaf lamination limited warranty limited warranty certificate, WA 0018
, is
included with this proposal.
0683627
Certification, Vehicle Stability,
CD0156

VEHICLE STABILITY CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the apparatus complies with NFPA
1901
, current edition, section

4.13 , Vehicle Stability. The certification will be provided at the time of bid.
0808580
Certification, Engine Installation,
Imp/Vel, Cummins X10, 2027

ENGINE INSTALLATION CERTIFICATION
The fire apparatus manufacturer will provide a certification, along with a letter from the engine manufacturer stating they approve of the engine installation in the bidder's chassis. The certification will be provided at the time of delivery. 0686786
Certification, Power Steering,
CD0098

POWER STEERING CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the power steering system as installed meets the requirements of the component supplier. The certification will be provided at the time of bid.
65 480
Bid #:

Page 504 of 665 ends

0892701
Certification, Cab Integrity,
Impel/Velocity FR, CD0190

CAB INTEGRITY CERTIFICATION
The fire apparatus manufacturer will provide a cab crash test certification with this proposal. The certification will state that a specimen representing the substantial structural configuration of the cab has been tested and certified by an independent third party test facility. Testing events will be documented with photographs, real-time and high-speed video, vehicle accelerometers, cart accelerometers, and a laser speed trap. The fire apparatus manufacturer will provide a state licensed professional engineer to witness and certify all testing events. Testing will meet or exceed the requirements below:

SAE J
2422
Cab Roof Strength Evaluation - Quasi-Static Loading Heavy Trucks.

European Occupant Protection Standard ECE Regulation No. 29 .

SAE J
2420
COE Frontal Strength Evaluation - Dynamic Loading Heavy Trucks.

Side Impact
The cab will be subjected to dynamic preload where a
14,320
-lbs moving barrier is slammed into
the side of the cab at

5.50 mph, striking with an impact of
13,000
ft-lbs of force. This test is part of
the SAE J
2422
test procedure and more closely represents the forces a cab will see in a rollover incident.

Roof Crush
The same cab will be subjected to a roof crush force of 22,050
lbs. This value meets the ECE
29 criteria, and is equivalent to the front axle rating up to a maximum of ten ( 10 ) metric tons.

Additional Roof Crush
The same cab will be subjected to a roof crush force of 100,000
lbs. (Four and a half times the
load criteria of ECE
29 )
Frontal Impact
The same cab will withstand a frontal impact of
32,600
ft-lb of force using a moving barrier in
accordance with SAE J
2420
.

Additional Frontal Impact
The same cab will withstand a frontal impact of
65,200
ft-lb of force using a moving barrier.
(Twice the force required by SAE J
2420
)
The same cab will withstand all tests without any measurable intrusion into the survival space of the occupant area.

There will be no exception to any portion of the cab integrity certification. Nonconformance will lead to immediate rejection of bid.
0548950
Certification, Cab Door Durability,
Velocity/Impel, CD0001

CAB DOOR DURABILITY CERTIFICATION
Robust cab doors help protect occupants. Cab doors will survive a 200,000
cycle door slam test
where the slamming force exceeds
20 G's of deceleration. The bidder will certify that the sample doors similar to those provided on the apparatus have been tested and have met these criteria without structural damage, latch malfunction, or significant component wear. 0548967
Certification, Windshield Wiper
Durability, Impel/Velocity, CD0005

WINDSHIELD WIPER DURABILITY CERTIFICATION
Visibility during inclement weather is essential to safe apparatus performance. Windshield wipers will survive a
3 million cycle durability test in accordance with section

6.2 of SAE J
198

Windshield
Wiper Systems - Trucks, Buses and Multipurpose Vehicles.

The bidder will certify that the wiper
system design has been tested and that the wiper system has met these criteria. 0667411
Certification, Electric Window
Durability, Velocity/Impel FR,
CD0004

ELECTRIC WINDOW DURABILITY CERTIFICATION
Cab window roll-up systems can cause maintenance problems if not designed for long service life. The window regulator design will complete
30,000
complete up-down cycles and still function
normally when finished. The bidder will certify that sample doors and windows similar to those provided on the apparatus have been tested and have met these criteria without malfunction or significant component wear.
0549273
Certification, Seat Belt Anchors and
Mounting, Imp/Vel/Vel SLT, CD0018

SEAT BELT ANCHOR STRENGTH
Seat belt attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat belt anchor design will withstand 3000
lb of pull on both
the lap and shoulder belt in accordance with FMVSS
571.210
Seat Belt Assembly Anchorages.

The bidder will certify that each anchor design was pull tested to the required force and met the appropriate criteria.

SEAT MOUNTING STRENGTH
Seat attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat mounting design will be tested to withstand 20 G's of force in
accordance with FMVSS
571.207
Seating Systems. The bidder will certify that each seat mount and cab structure design was pull tested to the required force and met the appropriate criteria. 66 480
Bid #:

Page 505 of 665 ends

0735950
Certification, Cab HVAC System Perf,
Vel/Imp FR,
CD0166/CD0168/CD0176/CD0177

PERFORMANCE CERTIFICATIONS
Cab Air Conditioning
Good cab air conditioning temperature and air flow performance keeps occupants comfortable, reduces humidity, and provides a climate for recuperation while at the scene. The cab air conditioning system will cool the cab from a heat-soaked condition at 100
degrees Fahrenheit to
an average of
78 degrees Fahrenheit in
30 minutes. The bidder will certify that a substantially similar cab has been tested and has met these criteria.

Cab Defroster
Visibility during inclement weather is essential to safe apparatus performance. The defroster system will clear the required windshield zones in accordance with SAE J 381
Windshield
Defrosting Systems Test Procedure And Performance Requirements - Trucks, Buses, And Multipurpose Vehicles.

The bidder will certify that the defrost system design has been tested in a cold chamber and passes the SAE J
381
criteria.

Cab Auxiliary Heater
Good cab heat performance and regulation provides a more effective working environment for personnel, whether in-transit, or at a scene. An auxiliary cab heater will warm the cab 77 degrees
Fahrenheit from a cold-soak, within
30 minutes when tested using the coolant supply methods found in SAE J
381
. The bidder will certify, at time of delivery, that a substantially similar cab has been tested and has met these criteria.
0545073
Amp Draw Report, NFPA Current
Edition

AMP DRAW REPORT
The bidder will provide, at the time of bid and delivery, an itemized print out of the expected amp draw of the entire vehicle's electrical system.

The manufacturer of the apparatus will provide the following:

Documentation of the electrical system performance tests.

A written load analysis, which will include the following:

The nameplate rating of the alternator.

The alternator rating under the conditions specified per:

Applicable NFPA
1901
or
1906
(Current Edition).

The minimum continuous load of each component that is specified per:

Applicable NFPA
1901
or
1906
(Current Edition).

Additional loads that, when added to the minimum continuous load, determine the total connected load.

Each individual intermittent load.

All of the above listed items will be provided by the bidder per the applicable NFPA 1901
or
1906

(Current Edition).
0002758
Amp Draw, NFPA/ULC Radio
Allowance

0799248
Appleton/Florida BTO

0000048
PUMPER/TANKER, 3rd Gen

0000012

PIERCE CHASSIS
0004713

ENGINE, OTHER
0046395
EVS 3000 Series TRANSMISSION
0520324

PIERCE PUMP, PUC

0020009

POLY TANK

0028048

FOAM SYSTEM
0020006

SIDE CONTROL
0020008

ELKHART VALVES
0020014

FRONT SUCTION

0020015

ABS SYSTEM

67 480
Bid #:

Page 506 of 665 ends

0658751

PUMPER BASE

68 480
Bid #:

Page 507 of 665 ends

Option
Description
Type*
Minimum
Load
Intermittent
Load
Total
Connected
0001244
High Idle w/Electronic Engine, Custom

0.00 1.20

0.00 0002526
Light, Engine Compt, All Custom Chassis

0.00 1.60

0.00 0006755
Remote Start, Gas Generator

0.00 1.20

0.00 0006825
Reel, Elect Cable, Hannay, 1600, (3) Wire

0.00 36.00

0.00 0010670
ABS Wabco Brake System, Single rear axle

0.00 6.00

0.00 0015216
Reel, Booster, Aluminum - Over Pump, Right Side

0.00 36.00

0.00 0032189
Mirrors, Ramco, 8000PCHR, Heated/Remote, w/Heated/Remote Convex, Door Mount

0.00 0.00

8.00 0062992
Gauge, Foam Level, (1) Tank, Class 1, GAAAR 5lt

0.00 0.00

1.00 0072153
Primer, Trident, Air Prime, Air Operated

0.00 0.01

0.00 0079212
Batteries, (6) Exide Grp 31, 950 CCA each, SAE Posts

0.00 3.00

0.00 0085910
Lights, Backup Included in Signal Cluster

0.00 4.20

0.00 0122465
Cab Lift, Elec/Hyd, Imp/Vel

0.00 180.00

0.00 0520326
Light, Pump Compt, PUC

0.00 1.80

0.00 0543751
Light, Do Not Move Apparatus

0.00 0.80

0.00 0549115
Lights, Side Scene, Wln 60C0ELZR Gradient LED 12, Semi- Recess Mounted, 1st

0.00 0.00

5.50 0549117
Lights, Side Scene, Wln 60C0ELZR Gradient LED 12, Semi- Recess Mounted, 2nd

0.00 0.00

5.50 0549333
Indicators, Engine, Included with Pressure Controller

0.00 0.35

0.00 0589905
Alarm, Back-up Warning, PRECO 1040

0.00 0.50

0.00 0628472
Light, Map, Overhead, Peterson M371S LED, Rectangular
w/Switch 2lts

0.00 0.24

0.00 0653526
Camera, Pierce, LS Mux, R, Camera

0.00 1.20

0.00 0667902
Controls, Electric Windows, All Cab Doors, Impel/Velocity FR

0.00 26.00

0.00 0676021
Foam Sys, Husky 3, Single Agent, PUC, Multi Select Feature

0.00 55.00

0.00 0676393
177" Hatch, (2) Lift-up, 21" Wide, Both Sides, RS Shortened for Cargo Area, PUC

0.00 3.25

3.25 0687994
Engine Brake, Jacobs Compression Brake, Cummins Engine

0.00 0.42

0.00 0699542
Intercom, Sigtronics US-67D, 7-Pos, 3-Dual Radio, D,O,4C,P

0.00 0.00

0.50 0732083
Handlts, (2) Streamlight Stinger HL 75432 kit, 12v, Charging Holder

0.00 0.50

0.00 0741239
HVAC, Impel/Velocity FR, CARE

0.00 0.00
136.00
0763926
Light Twr, W-B Chf NS1.8-600 WHL, 4-P*H2 12VDC Lts Cld 6'

0.00 0.00

48.00 0787001
Wiring, Spare, 4.8 A 12V DC, USB Termination Blue Sea 1045 2nd

0.00 0.00

5.00 0797189
Wiring, Spare, 4.8 A 12V DC, USB Termination Blue Sea 1045 1st

0.00 0.00

5.00 0803875
Radio, AM/FM/WB, Jensen, Frt,Rear Aux In/Frt,Rear
USB/Bluetooth

0.00 0.00

2.00 0895281
Siren, Federal Q2B, Littelfuse 24213 Sol

0.00 100.00

0.00 0548004
Wiring, Spare, 15 A 12V DC 1st
Load Managed

0.00 0.00

30.00 0548006
Wiring, Spare, 15 A 12V DC 2nd
Load Managed

0.00 0.00

45.00 0548009
Wiring, Spare, 20 A 12V DC 1st
Load Managed

0.00 0.00

40.00 0548013
Wiring, Spare, 20 A 12V DC 2nd
Load Managed

0.00 0.00

40.00 0776357
Light, Visor, Wln, 12V P*H2* Pioneer, Cnt Feature, 1st
Load Managed

0.00 0.00

13.00 0002758
Amp Draw, NFPA/ULC Radio Allowance
NFPA

5.00 0.00

0.00 0006133
Siren, Code 3 3692 100W or 200W
NFPA

1.40 12.60

0.00 0092582
Load Manager/Sequencer, MUX
NFPA

0.56 0.56

0.00 0516983
Gauges, Engine, Included With Pierce Pressure Controller, PUC NFPA

0.30 0.00

0.00 0517025
Lights, Tail, Wrap-around, Stop/Tail, Turn & Backup LED, Tri- Cluster
NFPA

2.60 7.80

0.00 0518345
LS 177" Rollup, (1) 50" Fwd, (1) 52" Rr, FH/FD Frt&Rr, PUC NFPA

6.00 0.00

6.00 0518346
RS 177" Rollup, (1) 50" Fwd, (1) 52" Rr, FH/FD Frt&Rr, PUC NFPA

6.00 0.00

6.00 0520243
Light, Pump Operator & Panel, Side Ctrl, PUC, Incandescent NFPA

7.84 0.00

0.00 0535157
Lights, Clearance/Marker/ID, Rear, Truck-Lite 33050R LED 7Lts,

PUC/HDRP
NFPA

0.50 0.00

0.00 0541116
Lights, Rear/Side Up Zone, Wln M6* LED, Colored Lens 4lts NFPA

4.00 0.00

0.00 * UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 1 Electrical Analysis
5/8/2023
Bid #:
480
Hanford FD (Duplicate 26797)
Sales Rep:

Organization:

Young, Dewayne
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer:

HANFORD FIRE DEPARTMENT
Option:

Pierce Command Zone, Advanced Electronics & Control
System, Impel, WiFi CZT
Type:

Multiplexed

Page 508 of 665 ends

Option
Description
Type*
Minimum
Load
Intermittent
Load
Total
Connected
0555915
Wiper Control, 2-Speed with Intermittent, MUX, Impel/Velocity NFPA

2.10 8.40

0.00 0557309
Compt, Rear, Rollup, 40.50" FF, w/Tailboard, PUC/HDRP
NFPA

0.90 0.00

0.90 0557322
Lights, Step, P25 at Rear Tailboard, PUC, 4lts Perm Lts NFPA

0.50 0.00

0.00 0564655
Lights, Rear Zn Lwr, Wln M6*C LED, Clear Lens, For Tail Lt Housing
NFPA

1.80 2.70

0.00 0568012
Air Dryer, Wabco System Saver 1200, Heater, 2010
NFPA

7.81 0.00

0.00 0582182
DEF Tank, 4.5 Gallon, DS Fill, Rear of Rear Axle, Common Door NFPA

0.60 11.40

0.00 0594554
Cab Instruments, Blk Gags, Blk Bez, Impel 2010
NFPA

1.26 0.00

0.00 0647647
Lights, Dome, FRP Dual LED 4 Lts
NFPA

0.80 0.80

0.00 0648074
Lights, Clearance/Marker/ID, Front, P25 LED 7 Lts
NFPA

0.49 0.00

0.00 0648425
Light, Directional, Wln 600 Cmb, Cab Crn, Imp/Vel/AXT/Qtm/DCF NFPA

0.70 0.70

0.00 0668316
Cab, Impel FR, 7010 Raised Roof, PUC
NFPA

6.80 10.20

0.00 0687514
Lights, Hatch Compt, LED Strip Light, 177", Both Sides
NFPA

1.58 1.58

0.00 0709438
Lights, Walk Surf, FRP Flood, LED
NFPA

2.00 0.00

0.00 0724463
Controller, Pressure, Pierce LCD, PUC
NFPA

1.70 0.00

0.00 0739224
Indicator Light @ Pump Panel, Throttle Ready, Incl w/Pressure Gov/Throttle,Green
NFPA

0.10 0.00

0.00 0750438
Water Level Gauge, Wln PSTANK2, LED 1-Light, 4-Level
NFPA

1.60 0.00

0.00 0750542
Light, Directional/Marker, Intermediate, Truck-Lite 60421Y LED 2lts
NFPA

0.10 1.00

0.00 0751350
Lightbar, Wln, Freedom IV-Q, 81", RRRRRWsrROptRsrWRRRRR NFPA

8.96 2.68

9.92 0752582
Cabinet, Rear Facing, RS, 21.5 W x 38 H x 26.5 D, Radius, Ext Acc, Imp/Vel
NFPA

0.22 0.22

0.00 0756688
Gauge, Water Level, Pierce, In pressure Controller, w/Mini Slave, PUC, Lt Driver
NFPA

1.23 0.00

0.00 0765628
Cabinet, Rear Facing, LS, 24 W x 38 H x 30.5 D, Radius, Ext Acc, Imp/Vel
NFPA

0.81 0.81

0.00 0766233
Headlights, Rect LED, Truck-Lite, AXT/DCF/Enf/Imp/Sab/Vel NFPA

2.40 2.40

0.00 0768474
Lights, Hose Bed, Below Alum Cvr, Amdor AY-LB-12HW040, 40" LED 4lts
NFPA

2.40 0.00

0.00 0769559
Lights, Perimeter Pump House, Amdor AY-LB-12HW012 LED 2lts NFPA

0.36 0.00

0.00 0769560
Lights, Perimeter Body, Amdor AY-LB-12HW012 LED 2lts, Rear Step
NFPA

0.36 0.00

0.00 0769569
Lights, Perimeter Cab, Amdor AY-LB-12HW012 LED 4Dr
NFPA

0.72 0.00

0.00 0770200
Handrail, Exterior, Hansen, Knurled, Alum, LED Backlit, 4-Door Cab
NFPA

0.80 0.00

0.00 0778195
Lights, Rear Scene, Wln, PCPSM1C Pioneer LED Fld/Spt,
Surface Mount
NFPA

12.00 0.00

0.00 0793476
Lights, Side Zone Lower, Wln M6** LED, PUC, 2pr
NFPA

3.60 5.40

0.00 0808533
Engine, Cummins X10, 450 hp, 1250 lb-ft, W/OBD, EPA 2027, Imp/Vel
NFPA

1.00 0.00

0.00 0887559
Trans, Allison 6th Gen, 3000 EVS P, w/Prognostics,
Imp/Vel/SFR/Enf
NFPA

2.00 2.00

0.00 0889577
Bracket, License Plate & Light, P25 LED, Stainless Brkt NFPA

0.07 0.00

0.00 0892637
Lights, Cab & Crw Cab Acs Stps, P25, LED w/Bezel, 1Lt Per Step NFPA

1.00 0.00

0.00 0892649
ClearSky Telematics for Remote Fleet and On-scene
Management
NFPA

1.61 0.00

0.00 0898734
Light, Front Zone, Wln M6** M6** M6** M6** Q Bzl
NFPA

1.80 5.40

1.80 0647728
Alternator, 430 amp, Delco Remy 55SI
S

0.00 0.00

0.00 Load Totals:
106.38
535.92
412.37
Note: Minimum Continous Load is in "Blocking Right of Way" mode.(Reference current edition of NFPA 1901) Note: Intermittent Load items are not factored in on any alternator load comparisons. These items are included on the report for reference only and should be looked at as amp draw exclusion items. (Reference current edition of NFPA 1901) Note: Total Connected Load "Demand" represents Total Connected Load minus any Load Managed items 253.00
371.00
Alternator Output at Idle:

Alternator Output at Governed Speed:
* UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 2 Electrical Analysis
5/8/2023
Bid #:
480
Hanford FD (Duplicate 26797)
Sales Rep:

Organization:

Young, Dewayne
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer:

HANFORD FIRE DEPARTMENT
Option:

Pierce Command Zone, Advanced Electronics & Control
System, Impel, WiFi CZT
Type:

Multiplexed

Page 509 of 665 ends

Minimum Continuous Load
Supply:
253.00
Demand:
106.38
Variance:
146.62
Total Connected Load
Supply:
371.00
Demand:
350.75
Variance:

20.25 * UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 3 Electrical Analysis
5/8/2023
Bid #:
480
Hanford FD (Duplicate 26797)
Sales Rep:

Organization:

Young, Dewayne
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer:

HANFORD FIRE DEPARTMENT
Option:

Pierce Command Zone, Advanced Electronics & Control
System, Impel, WiFi CZT
Type:

Multiplexed

Page 510 of 665 ends

Turning Performance Analysis
Bid Number:
480
Chassis:

Impel Chassis, PUC-NG
Department:

HANFORD FIRE DEPARTMENT
Body:

Pumper, PUC, Aluminum
Parameters:
*Inside Cramp Angle:
45°
Axle Track:

82.92 in.

Wheel Offset:

4.68 in.

Tread Width:

15.9 in.

Chassis Overhang:
78 in.

Additional Bumper Depth:
10 in.

Front Overhang:
88 in.

Wheelbase:
176.5 in.

Calculated Turning Radii:

Inside Turn:
13 ft. 8 in.

Curb to curb:
27 ft. 2 in.

Wall to wall:
31 ft. 7 in.

Notes:
*Actual Inside cramp angle may be less than shown.

Curb to Curb turning radius calculated for 9.00 inch curb. 05/08/2023
Category
Option
Description
Axle, Front, Custom
0508848
Axle, Front, Oshkosh TAK-4, Non Drive, 19,500 lb, Imp/Vel Bumpers
0123622
Bumper, 10" Extended, Imp/Vel
Tires, Front
0887447
Tires, Front, Michelin, X Multi HL Z , 385/65R22.50, Fire Service Speed Rtng Wheels, Front
0019611
Wheels, Front, Alcoa, 22.50" x 12.25", Aluminum, Hub Pilot

Page 511 of 665 ends

Definitions:

Inside CrampAngle
Maximum turning angle of the front inside fire.

Axle Track
King-pin to King-pin distance of front axle.

Wheel Offset
Offset from the center line of the wheel to the King-pin.

Tread Width
Width of the tire tread.

Chassis Overhang
Distance of the center line of the front axle to the front edge of the cab. This does not include the bumper depth.

Additional Bumper Wheel
Depth that the bumper assembly adds to the front overhang.

Wheelbase
Distance between the center lines of the vehicles front and rear axles.

Inside Turning Radius
Radius of the smallest circle around which the vehicle can turn.

Curb to Curb Turning Radius
Radius of the smallest circle around which the vehicle's tires can turn. This measures assumes a curb height of 9 inches.

Wall to Wall Turning Radius
Radius of the smallest circle around which the vehicle's tires can turn. This measures takes into account any front overhang due to chassis , bumper extensions and or aerial devices.

Page 512 of 665 ends

JROGHQVWDWHĆUHFRP

PRODUCT

WARRANTIES
Exhibit “C”
4

Page 513 of 665 ends

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0008

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

No specific exclusions apply
Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:

One (1) Year Material and Workmanship
Basic Apparatus
Twelve (12) months.Warranty Period
Ends After:

The date the apparatus is placed in service, or 60 days from the original buyer invoice date, whichever comes first.Warranty Begins:

Portions of the apparatus manufactured by Pierce shall be free from defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

Page 514 of 665 ends

Fire and Rescue Apparatus
Coverage:

Three (3) Year Material and Workmanship
Velocity and Impel Custom Chassis
Limited Warranty Limited Warranty Limited Warranty Limited Warranty Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Portions of the apparatus manufactured by Pierce shall be free from defects in material and workmanship

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date the apparatus is placed in service, or 60 days from the original buyer invoice date, whichever comes first. Warranty Begins:

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty applies, where applicable, to Goldstar lamination, defroster heater coil and motor blower assembly (excluding the FET PWM module), heater, air conditioning condenser coil and fan/motor assembly, air conditioning evaporator coil and motor blower assembly (excluding the drain pan pump and thermostat), under seat heaters coil and motor blower assembly (excluding the FET PWM module),
HVAC electronic switches, HVAC hoses and hard lines,
heater water valve, Pierce PS6 seat frames and hardware, Pierce One-Eleven mirrors, Pierce hands-free scba holder, cracking or color loss of roto-molded components, Meritor rear axle, Wabco ABS system, cab door handles, Standen
spring suspension components, and the gauge instrument
cluster.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGE S.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Three (3) Years, or
30,000 Miles, or
5000 Engine Hours
Warranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle.
7/2/2015 WA0284
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

Page 515 of 665 ends

Cummins Warranty
Worldwide
Fire Apparatus/Crash Trucks

Page 516 of 665 ends

Coverage
Products Warranted
This Warranty applies to new diesel Engines sold by
Cummins and delivered to the first user on or after
April 1, 2007, that are used in fire apparatus truck and crash truck* applications Worldwide.

Base Engine Warranty
The Base Engine Warranty covers any failures of the
Engine which result, under normal use and service,
from a defect in material or factory workmanship
(Warrantable Failure). This Coverage begins with the
sale of the Engine by Cummins and ends five years or
100,000 miles (160,935 kilometers), whichever occurs
first, after the date of delivery of the Engine to the first user .

Engine aftertreatment components included in the
Cummins Critical Parts List (CPL) and marked with a
Cummins part number are covered under Base Engine
Warranty.

Additional Coverage is outlined in the Emission
Warranty section.

These Warranties are made to all Owners in the
chain of distribution and Coverage continues to all
subsequent Owners until the end of the periods of
Coverage.

Cummins
Responsibilities
Cummins will pay for all parts and labor needed to
repair the damage to the Engine resulting from a
Warrantable Failure.

Cummins will pay for the lubricating oil, antifreeze,
filter elements, belts, hoses and other maintenance
items that are not reusable due to the Warrantable
Failure.

Cummins will pay for reasonable labor costs for
Engine removal and reinstallation when necessary to
repair a Warrantable Failure.

Cummins will pay reasonable costs for towing a
vehicle disabled by a Warrantable Failure to the
nearest authorized repair location. In lieu of the towing expense, Cummins will pay reasonable costs for
mechanics to travel to and from the location of the
vehicle, including meals, mileage and lodging when
the repair is performed at the site of the failure.

Owner
Responsibilities
Owner is responsible for the operation and
maintenance of the Engine as specified in Cummins
Operation and Maintenance Manuals. Owner is also
responsible for providing proof that all recommended
maintenance has been performed.

Before the expiration of the applicable Warranty,
Owner must notify a Cummins distributor ,authorized
dealer or other repair location approved by Cummins
of any Warrantable Failure and make the Engine
available for repair by such facility. Except for Engines disabled by a Warrantable Failure, Owner must also
deliver the Engine to the repair facility.

Service locations are listed on the Cummins Worldwide
Service Locator at cummins.com.

Owner is responsible for the cost of lubricating oil,
antifreeze, filter elements and other maintenance items provided during Warranty repairs unless such items
are not reusable due to the Warrantable Failure.

Owner is responsible for communication expenses,
meals, lodging and similar costs incurred as a result of a Warrantable Failure.

Owner is responsible for non-Engine repairs and for
‘‘downtime’’expenses, cargo damage, fines, all
applicable taxes, all business costs and other losses
resulting from a Warrantable Failure.

Owner is responsible for a $100 (U.S. Dollars)
deductible per each service visit under this plan in the 3rd, 4th and 5th years of Base Engine Warranty. The
deductible will not be charged during the first 2 years of the Base Engine Warranty.

Limitations
Cummins is not responsible for failures or damage
resulting from what Cummins determines to be abuse
or neglect, including, but not limited to: operation
without adequate coolants or lubricants; overfueling;
overspeeding; lack of maintenance of lubricating,
cooling or intake systems; improper storage, starting,
warm-up, run-in or shutdown practices; unauthorized
modifications of the Engine.

Any unauthorized modifications to the aftertreatment
could negatively effect emissions certification and void Warranty.

Cummins is also not responsible for failures caused by
incorrect oil, fuel or diesel exhaust fluid or by water , dirt or other contaminants in the fuel, oil or diesel

Page 517 of 665 ends

exhaust fluid.

This Warranty does not apply to accessories supplied
by Cummins which bear the name of another
company. Such non-warranted accessories include, but
are not limited to: alternators, starters, fans, air
conditioning compressors, clutches, filters,
transmissions, torque converters, vacuum pumps,
power steering pumps, fan drives and air compressors.

Cummins branded alternators and starters are covered
for the first two years from the date of delivery of the Engine to the first user ,or the expiration of the Base Engine Warranty, whichever occurs first.

Failures resulting in excessive oil consumption are not covered beyond the duration of the Coverage or
100,000 miles (160,935 kilometers) or 7,000 hours from
the date of delivery of the Engine to the first user ,
whichever of the three occurs first. Before a claim for excessive oil consumption will be considered, Owner
must submit adequate documentation to show that
consumption exceeds Cummins published standards.

Failures of belts and hoses supplied by Cummins are
not covered beyond the first year from the date of
delivery of the Engine to the first user or the duration of the Warranty, whichever occurs first.

Parts used to repair a Warrantable Failure may be new
Cummins parts, Cummins approved rebuilt parts or
repaired parts. Cummins is not responsible for failures resulting from the use of parts not approved by
Cummins.

A new Cummins or Cummins approved rebuilt part
used to repair a Warrantable Failure assumes the
identity of the part it replaced and is entitled to the remaining Coverage hereunder .

Cummins Inc. reserves the right to interrogate
Electronic Control Module (ECM) data for purposes of
failure analysis.

CUMMINS DOES NOT COVER WEAR OR WEAROUT
OF COVERED PARTS.

CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.

THIS W ARRANTYAND THE EMISSION W ARRANTY

SET FORTH HEREINAFTER ARE THE SOLE

W ARRANTIESMADE BY CUMMINS IN REGARD TO
THESE ENGINES. CUMMINS MAKES NO OTHER

W ARRANTIES,EXPRESS OR IMPLIED, OR OF

MERCHANT ABILITYOR FITNESS FOR A
P ARTICULARPURPOSE.

This Warranty gives you specific legal rights, and you
may also have other rights which vary from state to
state.

Emission
Warranty
Products Warranted
This Emission Warranty applies to new Engines
marketed by Cummins that are used in the United
States** in vehicles designed for transporting persons
or property on a street or highway. This Warranty
applies to Engines delivered to the first user on or after September 1, 1992.

Coverage
Cummins warrants to the first user and each
subsequent purchaser that the Engine is designed,
built and equipped so as to conform at the time of sale by Cummins with all U.S. federal emission regulations
applicable at the time of manufacture and that it is free from defects in material or factory workmanship which
would cause it not to meet these regulations within the longer of the following periods: (A) Five years or
100,000 miles (160,935 kilometers) of operation,
whichever occurs first, as measured from the date of
delivery of the Engine to the first user or (B) The Base Engine Warranty.

If the vehicle in which the Engine is installed is
registered in the state of California, a separate
California Emission Warranty also applies.

Limitations
Failures, other than those resulting from defects in
material or factory workmanship, are not covered by
this Warranty.

Cummins is not responsible for failures or damage
resulting from what Cummins determines to be abuse
or neglect, including, but not limited to: operation
without adequate coolants or lubricants; overfueling;
overspeeding; lack of maintenance of lubricating,
cooling or intake systems; improper storage, starting,
warm-up, run-in or shutdown practices; unauthorized
modifications of the Engine.

Any unauthorized modifications to the aftertreatment
could negatively effect emissions certification and void Warranty.

Cummins is also not responsible for failures caused by
incorrect oil, fuel or diesel exhaust fluid or by water , dirt or other contaminants in the fuel, oil or diesel
exhaust fluid.

Cummins is not responsible for non-Engine repairs,
‘‘downtime’’expenses, cargo damage, fines, all
applicable taxes, all business costs or other losses
resulting from a Warrantable Failure.

Page 518 of 665 ends

Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.

Bulletin 3381161
Printed in U.S.A. Rev. 08/09
©2001 Cummins Inc.

CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.
* Airport operated crash trucks and fire department
operated trucks employed to respond to fires,
hazardous material releases, rescue and other
emergency-type situations.
** United States includes American Samoa, the
Commonwealth of Northern Mariana Islands, Guam,
Puerto Rico and the U.S. Virgin Islands.

Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.

Bulletin 3381161
Printed in U.S.A. Rev. 08/09
/H230052001 Cummins Inc.

Page 519 of 665 ends
Page 520 of 665 ends
Page 521 of 665 ends
Page 522 of 665 ends
Page 523 of 665 ends

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

Fire and Rescue Apparatus
Coverage:

Lifetime Fifty (50) Year Structural Integrity
Chassis Frame & Crossmembers
Fifty (50) Years
(Expected Life of Apparatus)
Warranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:

Custom chassis frame rail and cross members manufactured by Pierce shall be free from defects in material and
workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/16/2010 WA0038

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This warranty does not apply to damage caused by corrosion.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

Page 524 of 665 ends

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty excludes brake pads, brake rotors, seal boots and shock absorbers.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGE S.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Three (3) Years
-or-
30,000 Miles
Warranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle.
12/16/2013 WA0050
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

Fire and Rescue Apparatus
Coverage:

Three (3) Year Material and Workmanship
TAK-4 Independent Front Suspension
Limited Warranty Limited Warranty Limited Warranty Limited Warranty Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The TAK-4 Front Independent Suspension and Steering
Gears shall be free from defects in material and
workmanship.

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

Page 525 of 665 ends

Fire and Rescue Apparatus
Coverage:

SUPPLIER
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The Meritor axle shall be covered by Meritor as indicated in the attached Meritor warranty coverage description

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the purchaser who first puts the product in service ("Buyer"):
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

The exclusions listed in the attached Meritor warranty
description shall apply.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Five (5) YearsWarranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 6/29/2020 WA0384
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

Page 526 of 665 ends

MERITOR
®

COMMERCIAL

VEHICLE SYSTEMS
WARRANTY/MODEL YEAR 2020 VEHICLES

Page 527 of 665 ends

Advantage Program
Purchasing additional coverage on select components will continue to safeguard your investment against major repair costs after the initial base coverage expires. You can find out more about the Advantage Program by visiting www.meritor.com or by contacting Meritor at 866-OnTrac1 (866-668-7221).
2 Linehaul ............................................................................................................. 3-4 General Service ................................................................................................... 5-6 Heavy Service/Specialty Vehicle .......................................................................... 7-8 Fire and Emergency ................................................................................................ 9 Transit Bus ........................................................................................................... 10 Off-Highway Service .............................................................................................. 11 Terms and Conditions ............................................................................................ 12 How to Read Warranty Coverage
Number of Years Mileage (in thousands)
Unl=Unlimited
P=Parts Only
P&L=Parts & Labor
Notice:

Models or components that are approved for use by Meritor’s vocational guidelines contained in Meritor Publication TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, which are not specifically listed, are warranted for one year, unlimited miles, parts only (1/Unl/P).

Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles parts only (1/Unl/P).

Effective Model Year 2020 Vehicles

WARRANTY INFORMATION CONTENTS

Page 528 of 665 ends

n Bulk Hauler
n Chip Hauler (Truck)*
n Doubles
n Flatbed
n General Freight
n Grain Hauler
n Livestock Hauler
n Moving Van
n Pipe Hauler
n Refrigerated Freight
n Tanker
n Triples
FD-965
FF-941
FF-942
FF-943
FF-944
FF-961
FF-966
FF-967
FG-941
FG-943
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122A-N
MFS-12-122B-N
MFS-12-122C-N
MFS-12E-122A-N
MFS-12E-122B-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12-132C-N
MFS-12E-132B-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12E-143A-N
MFS-12-144A-N
MFS-13-122A-N
MFS-13-122B-N
MFS-13-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-13B-122B-N
MFS-13B-122C-N
MFS-13B-132B-N
MFS-13B-132C-N
MFS-14-122A-N
MFS-14-124A-N
MFS-14-143A-N
MFS-14-144A-N
n High mileage operation (over 60,000 miles/year)
n Well maintained major highways of concrete or
asphalt construction
n Greater than 30 miles between starting and stopping
Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application approval questions on any product line. * Chip Hauler vehicles require specific axle models listed below and Linehaul condition to be eligible for Linehaul warranty consideration.

Linehaul Vehicles
Front Non-Drive Steer Axles – 5/750/P&L
Linehaul Typically Is
RPL 5/500/P , 1/Unl/P&L
MXL 3/350/P , 1/Unl/P&L
155N 1/Unl/P
92N 1/Unl/P
Drivelines
RS-19-144/145/A
MS-19-14X
MS-21-144
RS-21-145
RS-21-160
MS-23-17X
RS-23-160
RS-23-161
RS-23-186
Rear Drive Single Axles – 5/750/P&L
1 These models required for Chip Hauler and Linehaul warranty consideration. 2 Each vehicle must have a Request for Application Recommendation (RAR) approved by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details.

RT-34-144/P/A
RT-40-145/A
RT-40-160/P 1,2
RT-46-160/P 1,2
RT-46-164EH/P 1,2
RT-50-160/P 1,2
MA-40-165
MA-40-175
MT-34-14X/P
MT-40-14T/P
MT-40-14X/P
MT-40-14X/P
MT-40-14XHE
MT-40-144/P
MT-40-943
MT-40-943-SP
RZ-166 2
RZ-188
Rear Drive Tandem/Tridem Axles – 5/750/P&L

LINEHAUL WARRANTY INFORMATION
3

Page 529 of 665 ends

Cam Q Series Trailer Brakes 5/500/P , 1/100/L
Q+ Drum Brake™ 5/500/P , 1/Unl/P&L
ASA 5/500/P , 1/Unl/P&L
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
STEELite X30 Drum Brake™ 2 12-Years or Wearable Life/P
EX+ Air Disc Brake™ 5/500/P , 1/Unl/L
EX+ Air Disc Brake Extended Standard Warranty 3 5/500/P&L 1 Includes: bushing, seal, cam, ASA lubrication and wear coverage of 3/500/P&L.
2 Based on stamped wear diameter max.
3 Applies only to MA761 friction material code CD brake assembly i.e.

EX225LXXXCDXXX
MPA38/40 (Tandem Axle Parallelogram) 1
Major Structural Components 5/500/P , 1/100/L
Curbing Damage Warranty 2 5/500/P , 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs 2/200/P , 1/100/L
Bushings 5/P , 3/L
PinLoc Air Controls 1/100/P&L
PinLoc Actuator 3/300/P&L
MPA20 (Single Axle Parallelogram)
Major Structural Components 5/500/P , 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs 2/200/P , 1/100/L
Bushings 5/P , 3/L
MTA (Trailing Arm)
Major Structural Components 5/500/P , 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs & Rebound Straps 2/200/P , 1/100/L
Bushings 5/500/P , 3/300/L
1 Fastener torque coverage is limited to 2/Unl/P&L when torqued by Meritor (For axle and ABS coverage, refer to appropriate product warranties.) 2 “Curbing damage” is defined as deformation (bending, buckling, or breakage), caused by sudden impact with a curb or similar fixed object. Damage to the RideSentry slider box (the suspension sliding subframe, consisting of the frame rails, crossmembers, and central A-frame assembly), caused by accidental trailer impact with a curb or similar fixed object, is eligible for warranty coverage.

Damage to other components or damage resulting from collision with another vehicle, rollover or fire is not covered under this provision. Warranty is not transferrable to another trailer VIN, and coverage does not apply if the trailer is deemed to be a total loss, scrapped, or otherwise not salvageable.

TQ, TQD, TR, TRD Beam and Brackets 5/750/P&L
1 For brake components and ABS Coverage, refer to appropriate product warranties.

MTIS Components 5/Unl/P , 1/Unl/L
Beam and Brackets 5/500/P , 1/100/L
Wheel End Systems 1
Standard System 2 1/100/P&L
PreSet by Meritor 3 5/500/P&L
AxlePak5 4 5P/L
AxlePak7 5 7P/L
1 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage. 2 When installed by Meritor.
3 Requires approved hubcap stating PreSet by Meritor on hubcap face. 4 When specified with AxlePak5 wheel end system, coverage on MTIS thru-tee and stator is 5/Unl/P , 1/Unl/L.
5 When specified with AxlePak7 wheel end system, coverage on MTIS thru-tee and stator is 7/Unl/P , 1/Unl/L.
(For brake components and ABS coverage, refer to appropriate product warranties.)
Brake Components Trailer Air Suspension Systems
TAG/Pusher Axles1
Meritor Tire Inflation System
Trailer Axles
4 LINEHAUL WARRANTY INFORMATION

Page 530 of 665 ends

n Auto Hauler
n Beverage Truck
n Chip Hauler
n Cross Country Coach
n Flatbed
n Front Engine Commercial Chassis
n Front Engine Integral Coach
n General Freight
n Intercity Coach
n Intermodal Chassis
n Livestock Hauler
n Meat Packer
n Moving Van
n Municipal Truck
n Newspaper Delivery
n Pick-Up and Delivery
n Pipe Hauler
n Platform Auto Hauler
n Rear Engine Integral Coach
n Recreational Vehicles
n Refrigerated Freight
n School Bus
n Stake Truck
n Tanker
n Tanker Trailer
n Tour Bus
n Wrecker
FD-965
FF-941
FF-942
FF-943
FF-944
FF-946
FF-961
FF-966
FF-967
FG-941
FH-941
FH-946 1
FL-941
FL-943
MFS-6-151A-N
MFS-6-153B-N
MFS-6-162B-N
MFS-6-153C-N
MFS-6-162C-N
MFS-7-113C-N
MFS-7-153C-N
MFS-7-163C-N
MFS-8-113B-N
MFS-8-143A-N
MFS-8-153B-N
MFS-8-163B-N
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122A-N
MFS-12E-122A-N
MFS-12-122B-N
MFS-12E-122B-N
MFS-12-122C-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12E-132B-N
MFS-12-132C-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12-144A-N
MFS-12E-143A-N
MFS-13-122A-N
MFS-13-122B-N
MFS-13B-122B-N
MFS-13-122C-N
MFS-13B-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13B-132B-N
MFS-13B-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-14-122A-N
MFS-14-124A-N
MFS-14-143A-N
MFS-14-144A-N
MFS-16-122A-N
MFS-16-133A-N
MFS-16-135A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
n Lower mileage operations (less than 60,000 miles/year) n Generally, on-road service (less than 10% off-road)
n An average of three (3) miles between starting and stopping Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application approval questions on any product line.

General Service Vehicles
Front Non-Drive Steer Axles – 2/Unl/P&L
General Service Typically Is

GENERAL SERVICE WARRANTY INFORMATION
1 Can also be used with reduced steer angles in tag position in Coach Applications. 5 MS-17-13X
MS-17-14X
MS-19-13X
MS-19-14X
RS-17-144/145/A
RS-19-144/145/A
MS-21-13X
MS-21-14X
MS-21-144
MS-23-17X
RS-21-145/A
RS-21-160
RC-22-145
RC-22-145/A
RC-23-160
RC-23-161
RC-23-162 1
RC-23-165 1
RS-23-160
RS-23-161
RS-23-186
RS-24-160
RC-25-160
RS-26-185
MS-26-616
MS-26-616-SP
RS-30-185
MS-30-616
MS-30-616-SP
RS-35-380
71162
71163
79163
Rear Drive Single Axles – 2/Unl/P&L
1 3/Unl/P&L if PreSet by Meritor.

MT-34-14X/P
RT-34-144/P/A
MT-40-14T/P
MT-40-14X/P
MT-40-14XHE
MT-40-144/P
RT-40-145/A
MT-44-14X/P
RT-44-145/P
RT-46-169
MT-52-616
RT-52-1851
MT-58-616
RT-58-1851
MT-70-380
RZ-188
Rear Drive Tandem/Tridem Axles – 2/Unl/P&L
1 Each vehicle must have a Request for Application Recommendation (RAR) approved by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN.

Refer to Product Information Letter #303 and #396 for further details.

MX-08-130-FV (FSD-08A)
MX-10-130-FV (FSD-10A)
MX-12-130-FV (FSD-12A)
MX-13-130-FV (FSD-13A)
MX-14-130-FV (FSD-14A)
MX-16-130-FV (FSD-16A)
MX-18-130-FV (FSD-18A)
MX-18-130-SD (SDA-1800)
MX-20-130-FV (FSD-20A)
MX-21-130-FV (FSD-21A)
MX-21-130-SD (SDA-2100)
MX-23-130-FV (FSD-23A)
MX-23-130-SD (SDA-2300)
MX-29-130-FV (FSD-29A)
Front Drive/Non-Drive Steer Axles – 1/Unl/P&L
RT-40-160/P
RT-46-160/P
RT-46-164EH/P
RT-50-160/P
RZ-166
Rear Drive Tandem/Tridem -
3/Unl/P&L
RPL 4/400/P , 1/Unl/P&L
MXL 3/350/P , 1/Unl/P&L
155N 1/Unl/P
92N 1/Unl/P
Drivelines
11170
523
RND-14H
RND-16A
Rear Drive Axles – 1/Unl/P&L
MPT-318
MPT-500
MPT-510
MPT-518
MPT-526
MPT-531
MPT-543
MPT-170
MPT-1702
MPT-175
MPT-185
MPT-190
PTO – 1/Unl/P&L
516 FAT 30
Transmission – 1/Unl/P&L

Page 531 of 665 ends

Cam Q Series Trailer Brakes 3/Unl/P , 1/Unl/L
Cam P3 2/200/P
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
Q+ Drum Brake ™ 3 2/200/P&L
ASA 3/Unl/P
ASA3 2/200/P
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
STEELite X30 Drum Brake™ 2 12-Years or Wearable Life/P
EX+ Air Disc Brake™ 2/Unl/P&L
1 Includes: bushing, seal, cam, ASA lubrication and wear coverage of 1/Unl/P . 2 Based on stamped wear diameter max.
3 Applies to Tour Bus and Cross Country Coach only.

Beam and Brackets 1 5/Unl/P , 1/Unl/L
Wheel End Systems 2
Standard System 3 1/Unl/P&L
AxlePak5 4 5/P&L
AxlePak7 5 7/P&L
1 9000 Series is 3/Unl/P , 1/Unl/L
2 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage. 3 When installed by Meritor.
4 When specified with AxlePak5 wheel end system, coverage on MTIS thru-tee and stator is 5/Unl/P , 1/Unl/L.
5 When specified with AxlePak7 wheel end system, coverage on MTIS thru-tee and stator is 7/Unl/P , 1/Unl/L.
(For brake components and ABS coverage, refer to appropriate product warranties.)
Beam & Brackets 6/Unl/P , 1/Unl/L
Wheel End Systems 1
Standard System 1/Unl/P&L
AxlePak7 7/P&L
Beam and Brackets 7/P , 1/L
1 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage.

MPA38/40 (Tandem Axle Parallelogram) 1
Major Structural Components 5/Unl/P , 1/Unl/L
Curbing Damage Warranty 2 5/500/P , 1/100/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P , 1/Unl/L
Bushings 5/P , 3/L
PinLoc Air Controls 1/Unl/P&L
PinLoc Air Actuator 3/Unl/P&L
MPA20 (Single Axle Parallelogram)
Major Structural Components 5/Unl/P , 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P , 1/Unl/L
Bushings 5/P , 3/L
MTA (Trailing Arm)
Major Structural Components 5/Unl/P , 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs and Rebound Straps 2/Unl/P , 1/Unl/L
Bushings 3 5/Unl/P , 3/Unl/L
(For axle and ABS coverage, refer to appropriate product warranties.) 1 Fastener torque coverage is limited to 2/Unl/P&L when torqued by Meritor 2 “Curbing damage” is defined as deformation (bending, buckling, or breakage), caused by sudden impact with a curb or similar fixed object. Damage to the RideSentry slider box (the suspension sliding subframe, consisting of the frame rails, crossmembers, and central A-frame assembly), caused by accidental trailer impact with a curb or similar fixed object, is eligible for warranty coverage.

Damage to other components or damage resulting from collision with another vehicle, rollover or fire is not covered under this provision. Warranty is not transferrable to another trailer VIN, and coverage does not apply if the trailer is deemed to be a total loss, scrapped, or otherwise not salvageable. 3 Raw wood applications 3/Unl/P , 1/Unl/L
MTIS Components 5/Unl/P , 1/Unl/L
TQ, TQD, TR, TRD Beam and Brackets 1 3/Unl/P , 1/Unl/L MC14002, MC16003, FH946 2/Unl/P&L
(For brake components and ABS coverage, refer to appropriate product warranties.)
1 3/Unl/P&L if sold with PreSet by Meritor.

Brake Components
Trailer Axles
Chassis Axles (2000 Series/ChassiPak)
Trailer Air Suspension Systems
Meritor® Tire Inflation System
TAG/Pusher Axles
6 GENERAL SERVICE WARRANTY INFORMATION

Page 532 of 665 ends

Heavy Service/Specialty Vehicle
n Airport Rescue Fire Fighting
(ARFF)
n Airport Shuttle*
n Asphalt Truck
n Block Truck
n Bottom Dump Trailer
Combination
n Cementing Vehicle
n Commercial Pick-Up
n Concrete Pumper
n Construction Material Hauler
n Mixer
n Demolition
n Drill Rig
n Dump
n Equipment Hauling
n Flatbed Trailer Hauler
n Flatbed Truck
n Fracturing Truck
n Front Loader
n Geophysical Exploration
n Hopper Trailer Combinations
n Landscaping Truck
n Liquid Waste Hauler
n Log Hauling
n Lowboy
n Michigan Special Gravel Trains
n Michigan Special Log Hauler
n Michigan Special Steel Hauler
n Michigan Special Waste Vehicle
n Municipal Dump
n Rear Loader (Refuse)
n Recycling Truck
n Residential Pick-Up (Refuse)
n Rigging Truck
n Roll-Off
n Scrap Truck
n Semi-End Dump
n Sewer/Septic Vacuum
n Shuttle Bus*
n Side Loader
n Snowplow/Snowblower
n Steel Hauling
n Tanker
n Tank Truck
n Tractors with Pole Trailers
n Tractor/Trailer with Jeeps
n Transfer Dump
n Transfer Vehicle
n Utility Truck
n Winch Truck
n Moderate mileage operation (less than 60,000 miles per year) n On/Off road vocations (10% or more off-road)
n Moderate to frequent stops/starts (up to 10 stops per mile) Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/ or contact Meritor regarding specific application approval questions on any product line.

Heavy Service/Specialty Vehicle Typically Is
FD-965
FF-941
FF-942
FF-943
FF-944
FF-946
FF-961
FF-966
FF-967
FG-941
FG-943
FH-941
FH-946
FL-941
FL-943
MFS-6-151A-N
MFS-6-153B
MFS-6-162B
MFS-6-162C
MFS-7-113C-N
MFS-7-153C-N
MFS-7-163C-N
MFS-8-113B-N
MFS-8-153B-N
MFS-8-163B-N
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122
MFS-12E-122
MFS-12-122B-N
MFS-12E-122B-N
MFS-12-122C-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12E-132B-N
MFS-12-132C-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12-144A-N
MFS-12-155
MFS-13-122
MFS-13-122B-N
MFS-13B-122B-N
MFS-13-122C-N
MFS-13B-122C-N
MFS-13-132B-N
MFS-13B-132B-N
MFS-13-132C-N
MFS-13B-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-13-155
MFS-14-122
MFS-14-124A-N
MFS-14-143A-N
MFS-14-144A-N
MFS-16-122A-N
MFS-16-133A-N
MFS-16-135A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-192A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
RF-16-145
RF-21-160
MX-10-120
MX-10-120 EVO
MX-12-120
MX-12-120 EVO
MX-14-120
MX-16-120
MX-18-120
MX-17-140
MX-19-140
MX-21-140
MX-21-160
MX-23-160
MX-810
Front Drive/Non-Drive Steer Axles – 2/Unl/P&L

HEAVY SERVICE/SPECIAL TY VEHICLE

WARRANTY INFORMATION
7 *Commercial chassis only
MS-17-14X
RS-17-144/145/A
MS-19-14X
RS-19-144
MS-21-114
MS-21-14X
RS-21-145
RS-21-145/A
RS-21-160
RC-22-145
RC-23-160
RH-23-160
RS-23-160
RC-23-161
RS-23-161
RS-23-186/380
RS-24-160
RS-25-160
MS-26-616
MS-26-616-SP
RS-26-185/380
MS-30-616
MS-30-616-SP
RS-30-185/380
MS-35-380
RS-38-380
RC-25-160
RC-26-633
MT-58-616
MT-58-616-SP
Rear Drive Single Axles – 2/Unl/P&L
RPL 3/Unl/P , 1/Unl/P&L
92N 1/Unl/P&L
MXL 1/Unl/P&L
Drivelines
11170
523
RND-14H
RND-16A
Rear Drive Axles – 1/Unl/P&L
MX-08-130-FV (FSD-08A)
MX-10-130-FV (FSD-10A)
MX-12-130-FV (FSD-12A)
MX-13-130-FV (FSD-13A)
MX-14-130-FV (FSD-14A)
MX-16-130-FV (FSD-16A)
MX-18-130-FV (FSD-18A)
MX-18-130-SD (SDA-1800)
MX-20-130-FV (FSD-20A)
MX-21-130-FV (FSD-21A)
MX-21-130-SD (SDA-2100)
MX-23-130-FV (FSD-23A)
MX-23-130-SD (SDA-2300)
MX-29-130-FV (FSD-29A)
Front Drive/Non-Drive Steer Axles – 1/Unl/P&L
MPT-318
MPT-500
MPT-510
MPT-518
MPT-526
MPT-531
MPT-543
MPT-170
MPT-1702
MPT-175
MPT-185
MPT-190
PTO – 1/Unl/P&L
516
FAT 30
Transmission – 1/Unl/P&L

Page 533 of 665 ends

MT-34-14X/P
RT-34-144/P/A
MT-40-14X/P
RT-40-145/A
MT-44-14X/P
RT-44-145/P
RT-46-169
RT-58-160
MT-52-616
MT-52-616-SP
RT-52-185/380 1,2
MT-58-616
MT-58-616-SP
RT-58-185/380 1,2
RT-70-380
MT-70-380
RZ-188
Cam P 3/Unl/P
Cam P3 2/100/P
Cam Cast Plus™ 2/100/P&L
Q+ Drum Brake™ 3/Unl/P&L
Q+ Drum Brake™ 2 2/100/P&L
ASA 3/Unl/P
ASA2 2/100/P
Hubs/Cast Drums and
Other Wheel-end
Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake 2/100/P&L
1 Based on stamped wear diameter max.
2 Applies to City Bus, Trolley, Shuttle Bus and Airport Shuttle only.
3 Warranty for all non-Meritor ASAs supplied by
Meritor for all Heavy Service vocations is 1/100/P .

RT-40-160/P/A 3
RT-46-160/P/A 1,3
RT-46-164EH/P/A 2,3
RT-50-160/P/A 3
RZ-166
1 U.S. only. Canadian warranty = 1/Unl/P for
combination vehicles only.
2 Axle model designated will vary according to options and variations specified on these axles. Contact
Meritor Axle Applications Engineering for details.
3 Each vehicle must have a Request for Application
Recommendation (RAR) approved by Meritor prior
to vehicle build. All RARs must identify the chassis
number or VIN. Refer to Product Information Letter
#303 and #396 for further details.
1 Axle model designated will vary according to options and variations specified on these axles. Contact Meritor Axle Applications Engineering for details. 2 Each vehicle must have a Request for Application Recommendation (RAR) approved by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN.

Refer to Product Information Letter #303 and #396 for further details.

Rear Drive Tandem/Tridem Axles – 2/Unl/P&L
Brake Components Rear Drive Tandem/Tridem -
3/Unl/P&L MTA (Trailing Arm)
Major Structural Components1 5/Unl/P , 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P , 1/Unl/L
Bushings 1 5/Unl/P , 3/Unl/L
1 Raw wood applications 3/Unl/P , 1/Unl/L
(For axle and ABS coverage, refer to appropriate
product warranties.)
Trailer Air Suspension Systems
MTIS Components 5/Unl/P , 1/Unl/L
Meritor Tire Inflation System
Beam and Brackets 1 5/Unl/P , 1/Unl/L
Wheel End Systems 2
Standard System 3 1/Unl/P&L
1 9000 Series is 3/Unl/P , 1/Unl/L.
2 Includes hub, wheel seals and wheel bearings—all
systems require annual inspections and proper
documentation to ensure full coverage.
3 When installed by Meritor.
(For brake components and ABS coverage,
refer to appropriate product warranties.)
Trailer Axles
8 HEAVY SERVICE/SPECIAL TY VEHICLE

WARRANTY INFORMATION
MTC-4213
MTC-4210
MTC-4208
MTC-4206-FV (TC-38)
MTC-3106-FV (TC-137)
MTC-3111 (T-2111)
MTC-3112-CV (529 & 548C)
MTC-3116 (T-2111)
MTC-3118-FV (TC-180 & TC-180-23)
MTC-3118-CV (358)
MTC-3120-FV (TC-143)
MTC-3124 (T-2119)
MTC-3205-GV (MTC-25/247)
MTC-3205-GV (MTC-25/350)
MTC-3205-GV (RTC-25/350)
MTC-3206-FV (TC-237)
MTC-3206-CS (544)
MTC-3208-GV (RTC-50)
MTC-3209-GV (RTC-60/420)
MTC-3209-GV (RTC-60/380)
MTC-3209-GV (MTC-60/420)
MTC-3209-GV (MTC-60/380)
MTC-3212-CV (315 & 548B)
MTC-3312-FV (TC-270)
MTC-3220-FC (TC-142)
MTC-2212-CV (306)
Transfer Cases – 1/Unl/P
MGX-240
MGX-279
MGX-279D
MGX-280
MGX-285
MGX-292
MGX-314
MGX-376
MGX-377
MGX-378
MGX-380
MGX-384
MGX-402
MGX-413
MGX-448
MGX-456
MGX-478
MGX-480
MGX-487
MGX-488
MGX-505
MGX-506
MGX-514
MGX-519
MGX-520
MGX-522
MGX-524
MGX-527
MGX-528
MGX-533
MGX-534
MGX-536
MGX-537
MGX-541
MGX-545
MGX-546
MGX-550
Gearboxes – 1/Unl/P&L

Page 534 of 665 ends

n Aerial Ladder Truck
n Aerial Platform
n Ambulance
n Command Vehicle
n Crash Fire Rescue (CFR)
n Pumper
n Rapid Intervention Vehicle (RIV)
n Tanker
FL-941
FL-943
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
MX-19140
MX-21140
MX-21160
MX-23160
MX-23810
n Lower mileage operations (less than 20,000 miles/year) n Generally, on-road service (less than 10% off-road)
n An average of three (3) miles between starting and stopping Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application approval questions on any product line.

Fire and Emergency Vehicles
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
ASA 3/Unl/P
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake™ 2/Unl/P&L
1 Includes: bushing, seal, cam, ASA lubrication and wear coverage of 1/Unl/P .

Brake ComponentsFront Non-Drive Steer Axles – 5/Unl/P&L Front Drive Steer Axles – 2/Unl/P&L
Fire and Emergency Typically Is
RPL 4/400/P , 1/Unl/L
MXL 3/350/P , 1/Unl/L
155N 1/Unl/P
92N 1/Unl/P
Drivelines
MTC-4208
MTC-4210
MTC-4213
MTC-3111 (T-2111)
MTC-3116 (T-2111)
MTC-3124 (T-2119)
Transfer Cases – 1/Unl/P
RC-23-160
RS-23-160
RS-23-161
RS-23-186
RS-24-160
RC-25-160
RS-26-185
RS-30-185
RS-35-380
RS-25-160
Rear Drive Single Axles – 5/Unl/P&L
1 3/Unl/P&L if PreSet by Meritor.

MT-40-14X/P
MT-40-144/P
RT-40-145/A
RT-40-160/P
MT-44-14X/P
RT-44-145/P
RT-46-160/P
RT-46-164EH/P
RT-46-169
RT-50-160/P
MT-52-616
RT-52-1851
MT-58-616
RT-58-1851
MT-70-380
Rear Drive Tandem/Tridem Axles – 5/Unl/P&L
1 Each vehicle must have a Request for Application Recommendation (RAR) approved by Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details.

FIRE AND EMERGENCY WARRANTY INFORMATION
9

Page 535 of 665 ends

Transit Bus Vehicles
Cam Cast Plus™ 2/100/P&L
Q+ Drum Brake™ 1 2/100/P&L
ASA1 2/100/P
Hubs/Cast Drums and
Other Wheel-end
Components 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake 2/100/P&L
1 Applies to City Bus, Trolley, Shuttle Bus and Airport Shuttle only.

MC-26000
71063
79063
Brake Components Center Non-drive Axles – 5/300/P&L
n Airport Shuttle
n City Bus
n Commuter Coach
n Shuttle Bus
n Transit Bus
n Trolley
n Moderate mileage operation (less than 50,000 miles per year) n Moderate to frequent stops/starts (up to 10 stops per mile) Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP- 9441 for axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application approval questions on any product line.

Transit Bus Typically Is
FH-946
FH-941 1
MFS-12-155
MFS-13-155
RS-23-160
RC-23-161
71163
79163
RC-23-162 1
RC-23-165 1
RS-21-160
Front Drive/Non-Drive Steer Axles – 5/300/P&L
Rear Drive Single Axles – 5/300/P&L
RPL 3/Unl/P , 1/Unl/L
92N 1/Unl/P&L
MXL 1/Unl/P&L
MC-14002
MC-16003
FH-946
Drivelines
Tag Axles – 2/Unl/P&L

TRANSIT BUS WARRANTY INFORMATION
10 1 Commuter coach only – 2/Unl/P&L
1 Commuter coach only – 2/Unl/P&L

Page 536 of 665 ends

Industrial And Off-Highway Service Vehicles
n Load-On/Load-Off
n Port Tractor
n Rail Yard Spotter
n Roll-On/Roll-Off
n Stevedoring Tractor
n Trailer Spotter
n Yard Jockey
n All-Terrain Crane
n Rough Terrain Crane
n Forestry
n Material Handling
n Specialized Heavy Haul
n Specialized Mining
n Excavator
n Compactor
n Fertilizer Spreader
n Snow Blower
n Mining
n Rail Car Mover
n Loader
n Tow Tractor
n Pushback Tractor
n Low mileage operation
n Low speed vehicle speed restriction
n Vehicles are not typically licensed for highway use
n Six (6) starts/stops per mile (typical)
Coverage under Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Meritor approvals. Contact Meritor regarding specific application approval questions on any product line.

RPL MXL
FF - 941
FF - 943
FF - 961
FF - 966
FG - 941
FG - 943
FL - 941
FL - 943
FN - 951
MFS-12-143A-N
MFS-12-144A-N
MFS-13-143A-N
MFS-13-144A-N
MFS-14-143A-N
MFS-16-122A-N
MFS-16-133A-N
MFS-16-135A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
MON-Z0 FAMILY
Industrial And Off-Highway Service Typically Is
Drivelines – 1/Unl/P
MOB
MOC
MOD
MOE
MOF
MOG
MOH
MOR
MOS
MOT
MOX
MOY
MOZ
Planetary Axles – 1/Unl/P
Cam P 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
ASA 3/Unl/P
Hubs/Cast Drums and Other Wheel-end Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
Brake ComponentsFront Non-Drive Steer Axles – 1/Unl/P

OFF-HIGHWAY SERVICE WARRANTY

INFORMATION
11 MTC-4213
MTC-4210
MTC-4208
MTC-4206-FV (TC-38)
MTC-3106-FV (TC-137)
MTC-3111 (T-2111)
MTC-3112-CV (529 & 548C)
MTC-3116 (T-2111)
MTC-3118-FV (TC-180 & TC-180-23)
MTC-3118-CV (358)
MTC-3120-FV (TC-143)
MTC-3124 (T-2119)
MTC-3205-GV (MTC-25/247)
MTC-3205-GV (MTC-25/350)
MTC-3205-GV (RTC-25/350)
MTC-3206-FV (TC-237)
MTC-3206-CS (544)
MTC-3208-GV (RTC-50)
MTC-3209-GV (RTC-60/420)
MTC-3209-GV (RTC-60/380)
MTC-3209-GV (MTC-60/420)
MTC-3209-GV (MTC-60/380)
MTC-3212-CV (315 & 548B)
MTC-3312-FV (TC-270)
MTC-3220-FC (TC-142)
MTC-2212-CV (306)
Transfer Cases – 1/Unl/P
MGX-240
MGX-279
MGX-279D
MGX-280
MGX-285
MGX-292
MGX-314
MGX-376
MGX-377
MGX-378
MGX-380
MGX-384
MGX-402
MGX-413
MGX-448
MGX-456
MGX-478
MGX-480
MGX-487
MGX-488
MGX-505
MGX-506
MGX-514
MGX-519
MGX-520
MGX-522
MGX-524
MGX-527
MGX-528
MGX-533
MGX-534
MGX-536
MGX-537
MGX-541
MGX-545
MGX-546
MGX-550
Gearboxes – 1/Unl/P&L

Page 537 of 665 ends

Coverage Exclusions
Product Description
All
The cost of any repairs, replacements or adjustments to a covered component (1) associated with noise; (2) resulting from the use or installation of non-genuine Meritor components or materials; (3) due to vibration associated with improper operation or misapplication of drivetrain components; and (4) damage resulting from corrosion.

For axle assemblies supplied by Meritor with suspension and in - terface brackets designed and/or attached by non-Meritor parties, Meritor warranty coverage does not apply to the brackets, bracket attachment methods, and field issues caused by brackets or bracket attachments to any covered component unless specified in a separate OEM agreement.

Front Axles
King Pin Bushings.

Rear Axles
Self-contained traction equalizers and oil filters. The use of NoSPIN differentials will result in the exclusion of axle shafts from warranty considerations. NoSPIN is a product of Eaton.

ASA
Boot and bushing. Bent, broken, over-torqued, missing or otherwise damaged pawl assemblies.

Cam Brake
Brake lining wear and brake shoe “rust-jacking.”
Disc Brake
Pad wear, rotor wear.

Coverage Limitations
Product Description
All
Any claim beyond 60 days from date of repair will not be accepted or honored under this warranty program. Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles parts only (1/Unl/P).

Front Axles
Tie rod and tie rod ends limited to 3-year/300,000-mile or published vocational coverage, whichever is less. Wheel seals, gaskets and wheel bearings are covered for 1 year/unlimited miles if the wheel end equipment is supplied and assembled by Meritor.

Rear Axles
Pinion and through shaft seals limited to 3-year/300,000-mile or published vocational coverage, whichever is less, if yoke is installed by Meritor. If yoke is not installed by Meritor, then Meritor does not warrant pinion seals. Wheel seals, gaskets and wheel bearings are covered for 1 year/unlimited miles if the wheel end equipment is supplied and assembled by Meritor.

Rear Axles
The Meritor ® breather part number A-2297-C-8765 with
A-3196-J-1336 hose must be used for eligibility of any potential warranty consideration relating to contamination and/or loss of lube in axles.

Cam Brake
Limited to bracket, brake spider and camshaft structural integrity.

STEELite X30
Wearable life is up to the discard diameter of the drum.

Disc Brake
Warranty coverage for boots, seals, bushings and pins is 2/200/P .

Warranty coverage for pads is 1/100/P .

Warranty coverage on vehicles with 1,850 lb-ft engine torque and over may be reduced on individual drivetrain components. Contact your Meritor representative for specific details.
12 TERMS AND CONDITIONS

Page 538 of 665 ends

For more information:
call Ontrac at 866-668-7221
or visit meritor.com
©2018 Meritor, Inc.

Litho in USA, SP-95155
Revised 1-19 (47865/11900)
Meritor Heavy Vehicle Systems, LLC
2135 West Maple Road
Troy, Michigan 48084 USA
Product models, brands, names and trademarks depicted herein are the property of their respective owners and, except where otherwise indicated, are not in any way associated with Meritor Heavy Vehicle Systems, LLC, or any parent or affiliate, thereof.

TERMS AND CONDITIONS
(1) What is Covered by this Commercial Warranty?
Meritor Heavy Vehicle Systems, LLC warrants to the owner (“Owner”) that the components listed in this publication, which have been installed by an Original Equipment Manufacturer (“OEM”) as original equipment in vehicles licensed for on-highway use, will be free from defects in material and workmanship. This warranty coverage begins only after the expiration of the OEM’s vehicle warranty for the applicable covered components. Warranty coverage ends at the expiration of the applicable time period from the date of vehicle purchase by the first Owner, or, the applicable mileage limitation, whichever occurs first.

Duration of coverage varies by component and vocation as detailed elsewhere in this warranty statement.

Some components are warranted for parts only and the Owner must pay any labor costs associated with the repair or replacement of the component. Other components are warranted for both parts and reasonable labor to repair or replace the subject component.

Components (whether new, used or remanufactured) installed as replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty.

For certain components, coverage requires the use of specific extended drain interval or synthetic lubricants. For further information about lubrication and maintenance, see Meritor publication Maintenance Manual Number l and the applicable Meritor
maintenance manual for the product in question. Other conditions and limitations applicable to this warranty are detailed below. (2) Designation of Vocational Use Required.

To obtain warranty coverage, each Owner must notify Meritor through the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the Meritor components have been incorporated prior to the vehicle in-service date. This notification may be accomplished by registering the vehicle through your OEM new truck and/or trailer dealer or with Meritor directly. Failure to notify Meritor of (I) the intended vocational use of the vehicle or (II) a change in vocational use from that which was originally designated, will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial in-service date.

A second Owner and each subsequent Owner must also notify Meritor as to the intended vocational use of the vehicle. This notification can be sent directly to Meritor or through the OEM new truck and/or trailer dealer. The duration and mileage coverage of this warranty cannot exceed the coverage extended to the first Owner after his or her initial designation of vocational use.

Coverage under Meritor’s warranty requires that the application of products be properly approved pursuant to OEM and Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines, and/or contact Meritor regarding specific application approval questions on any product line.
(3) What is the Cost of this Warranty?
There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty?
This warranty does not cover normal wear and tear; nor does it cover a component that fails, malfunctions or is damaged as a result of (I) improper installation, adjustment, repair or modification (including the use of unauthorized attachments or changes or modification in the vehicle’s configuration, usage, or vocation from that which was originally approved by Meritor), (II) accident, natural disaster, abuse, or improper use (including loading beyond the specified maximum vehicle weight or altering engine power settings to exceed the axle and/or driveline capacity), or (III) improper or insufficient maintenance (including deviation from approved lubricants, change intervals, or lube levels). This warranty does not cover any component or part that is not branded by Meritor. For vehicles that operate full or part time outside of the United States and Canada, a one year, unlimited mileage, parts only warranty (1/Unl/P) will apply. (5) Remedy.

The exclusive remedy under this warranty shall be the repair or replacement of the defective component at Meritor’s option. Meritor reserves the right to require that all applicable failed materials are available and/or returned to Meritor for review and evaluation. (6) Disclaimer of Warranty.

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES

OR CONDITIONS, EXPRESSED, IMPLIED OR STATUTORY INCLUDING

ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
PARTICULAR PURPOSE.
(7) Limitation of Remedies.

In no event shall Meritor be liable for special, incidental, indirect, or consequential damages of any kind or under any legal theory, including, but not limited to, towing, downtime, lost productivity, cargo damage, taxes, or any other losses or costs resulting from a defective covered component.
(8) To Obtain Service.

If the Owner discovers within the applicable coverage period a defect in material or workmanship, the Owner must promptly give notice to either Meritor or the dealer from which the vehicle was purchased. To obtain service, the vehicle must be taken to any participating OEM new truck and/or trailer dealer or authorized Meritor service location.

The dealer will inspect the vehicle and contact Meritor for an evalu - ation of the claim. When authorized by Meritor, the dealer will repair or replace during the term of this warranty any defective Meritor component covered by this warranty.
(9) Entire Agreement.

This is the entire agreement between Meritor and the Owner about warranty and no Meritor employee or dealer is authorized to make any additional warranty on behalf of Meritor. This agreement allocates the responsibilities for component failure between Meritor and the Owner.

Page 539 of 665 ends

)LUHDQG5HVFXH$SSDUDWXV
Coverage:
7KUHH

<HDU0DWHULDODQG:RUNPDQVKLS
0HULWRU:DEFR$%6%UDNH6\VWHP
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The Meritor Wabco ABS brake system shall be covered by
Meritor Wabco as indicated in the attached Meritor Wabco warranty coverage description
/,0,7(':$55$17<
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Three (3) YearWarranty Period
Ends After:

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

The exclusions listed in the attached Meritor Wabco warranty description shall apply.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
(;&/86,212)&216(48(17,$/$1',1&,'(17$/'$0$*(6
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
%8<(5
6(;&/86,9(5(0('<
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle.
2/25/2013 WA0232
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
',6&/$,0(562):$55$17,(6
capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

Page 540 of 665 ends

WARRANTY
Warranty coverage is essential to protecting your investment. But understanding the full details of your coverage can be challenging. This straightforward approach allows you, our valued customer, to better understand how your specific vehicle applications will be covered in your region. Our component warranty coverage is provided according to vocation/usage categories listed below. • Linehaul covers high mileage operation (over 60,000 miles/year) on well-maintained major highways of concrete or asphalt construction.
• General Service covers moderate mileage operations (less than 60,000 miles/year) on well-maintained public roads (less than 10 percent off-road) typically with less than three (3) stops per mile. • Heavy Service (Vocational) covers vehicles with more than 10 percent off-road OR moderate to frequent starts/stops typically with more than three (3) stops per mile.
• Off-Highway Service covers lower mileage operations. Vehicles are not typically licensed for highway use. • The standard aftermarket warranty for WABCO products - including WABCO Original parts, WABCO Reman Solutions, ProVia quality aftermarket parts and WABCO retrofit solutions - is one year, parts only from in-service date when purchased from ZF distributor networks or its affiliates and/or subsidiaries.

MODEL YEAR 2021 VEHICLES
How to Read Warranty Coverage (Example)
Number of Years Mileage (in thousands) Unl=Unlimited P=Parts Only P&L=Parts & Labor 3 300 P

Page 541 of 665 ends

WARRANTY - MODEL YEAR 2021 VEHICLES
¹ ZF and WABCO branded components.
2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve.
• Aerial Ladder Truck
• Aerial Platform
• Ambulance
• Auto Hauler
• Beverage Truck
• Bulk Hauler
• Chip Hauler (Truck)
• Cross Country Coach
• Doubles
• Flatbed
• Front Engine Commercial
Chassis
• Front Engine Integral
Coach
• General Freight
• Grain Hauler
• Intercity Coach
• Intermodal Chassis
• Livestock Hauler
• Meat Packer
• Moving Van
• Municipal Truck
• Pipe Hauler
• Platform Auto Hauler
• Pumper
• Rear Engine Integral Coach
• Recreational Vehicles
• Refrigerated Freight
• School Bus
• Stake Truck
• Tanker
• Tanker Truck
• Triples
• Tour Bus
• Wrecker

LINEHAUL/GENERAL SERVICE VEHICLES

LINEHAUL/GENERAL SERVICE WARRANTY INFORMATION

LINEHAUL TYPICALLY IS
• High mileage operation (over 60,000 miles/year)
• Well maintained major highways of concrete or
asphalt construction

GENERAL SERVICE TYPICALLY IS
• Moderate mileage operations (less than 60,000 miles/year) • Well maintained public roads (less than 10% off-road) • Less than three (3) stops per mile
WABCO Components1
Air Management
Air Brake Valves
1/100/P&LTrailer Lift Axle Control Valve
Trailer Control Line Filter3
Air Compressors (ALL)2 2/200/P&L
Air Dryers (ALL) 3/300/P&L
Aerodynamics
OptiFlow® TrailerSkirt 2/UnU/P
OptiFlow® Trailer Tail and AutoTail 2/UnI/P
Braking Systems
ABS (Anti-Lock Braking System) Air
3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic
Electronic Braking System (EBS)
Electronic Stability Control (ESC)
Roll Stability Control (RSS)
Trailer Roll Stability Support (RSS)
Trailer ABS (Anti-Lock Braking System)
3 Driveline Suspension Control
Clutch Controls 2/200/P&L
Leveling Valves
1/100/P&L
OptiRide® Automated Manual Transmission (AMT)
OptiRide® Electronically Controlled Air Suspension
(ECAS) 3/300/P&L
WABCO Components1 (cont.)
Safety
OnGuardACTIVE®
3/300/P&L
OnLane®
OnLaneALERT®
OnSide®
Trailer SafeStart™
Trailer TailGUARD™
Telematics
TrailerCAST™ Telematics Device 3/300/P&L
Wheel End Solutions
EasyFit™ Slack Adjuster 6/600/P
MAXXUS™ Truck Air Disc Brake 5/500/P&L
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 17 and 19 Air Disc Brake 2/Unl/P and
1/Unl/L
Pan 22 Air Disc Brake 5/500/P and 1/L
TRISTOP™ D Actuator w/ IBV or IRB 6/600/P
TRISTOP™ D Actuator 3/300/P
UNISTOP™ Actuator 2/200/P
Trailer MAXX22T™ Air Disc Brake 5/500/P and 1/L

Page 542 of 665 ends

1 ZF and WABCO branded components. 2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve.

WABCO Components1
Air Management
Air Brake Valves
1/100/P&L
Air Compressors (ALL)2
Air Dryers (ALL)
Trailer Control Line Filter3
Braking Systems
ABS (Anti-Lock Braking System) Air 3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic 2/200/P&L
Electronic Braking System (EBS)
3/300/P&L
Electronic Stability Control (ESC)
Trailer ABS Valve3
Roll Stability Control (RSS)
Trailer Roll Stability Support (RSS)
Driveline Suspension Control
OptiRide® Electronically Controlled Air Suspension
(ECAS) 2/200/P&L
Leveling Valves 1/100/P&L
Clutch Controls 2/200/P&L
Safety
OnGuardACTIVE®
3/300/P&L
OnLane®
OnLaneALERT®
OnSide®
Trailer SafeStart™
Trailer TailGUARD™
Telematics
TrailerCAST™ Telematics Device 3/300/P&L
Wheel End Solutions
EasyFit™ Slack Adjuster 2/200/P
MAXXUS™ Air Disc Brake 1/Unl/P&L
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 22, 19 and 17 Air Disc Brake 1/Unl/P&L
Trailer MAXX22T™ 1/Unl/P&L
TRISTOP™ D Actuator w/ IBV 3/Unl/P
TRISTOP™ D Actuator 2/200/P
UNISTOP™ Actuator 1/100/P
• Airport Rescue Fire (ARF)
• Airport Shuttle
• Asphalt Truck
• Block Truck
• Bottom Dump Trailer
Combination
• Cementing Vehicle
• City Bus
• Commercial Pick-Up
• Concrete Pumper
• Construction Material Hauler
• Crash Fire Rescue (CFR)
• Mixer
• Demolition
• Drill Rig
• Dump
• Emergency Service
• Equipment Hauling
• Flatbed Trailer Hauler
• Flatbed Truck
• Fracturing Truck
• Front Loader
• Geophysical Exploration
• Hopper Trailer Combinations
• Landscaping Truck
• Liquid Waste Hauler
• Log Hauling
• Lowboy
• Michigan Special
Gravel Trains
• Michigan Special
Log Hauler
• Michigan Special
Steel Hauler
• Michigan Special
Waste Vehicle
• Municipal Dump
• Newspaper Delivery
• Package Delivery
• Pick-up and Delivery
• Rapid Intervention
Vehicle (RIV)
• Rear Loader
• Recycling Truck
• Residential Pick-Up/Waste
• Rigging Truck
• Roll-Off
• Scrap Truck
• Semi-End Dump
• Sewer/Septic Vacuum
• Shuttle Bus
• Side Loader
• Snowplow/Snowblower
• Steel Hauling
• Tanker
• Tank Truck
• Tractors with Pole Trailers
• Tractor/Trailer with Jeeps
• Transfer Dump
• Transfer Vehicle
• Transit Bus
• Trolley
• Utility Truck
• Winch Truck

HEAVY SERVICE VEHICLES

HEAVY SERVICE (VOCATIONAL) WARRANTY INFORMATION

HEAVY SERVICE TYPICALLY IS
• On/Off road vocations (10% or more off-road) OR
• Moderate to frequent starts/stops typically more than three (3) stops per mile

Page 543 of 665 ends

WARRANTY - MODEL YEAR 2021 VEHICLES

INDUSTRIAL AND OFF-HIGHWAY SERVICE

TYPICALLY IS
• Low mileage operation3
• Vehicles are not typically licensed for highway use
¹ ZF and WABCO branded components. 2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 Equivalent hours of service limit: 2,000 hours for all components.

INDUSTRIAL/OFF-HIGHWAY SERVICE WARRANTY INFORMATION
WABCO Components1
Air Management
Air Brake Valves
2/Unl/PAir Compressors (ALL)2
Air Dryers (ALL)
Brake Actuation
Air/Hydraulic Actuators
2/Unl/P
Master Cylinders
Remote Actuators
Slave and Wheel Cylinders
Two Fluid Actuators
Brake Locks
Brake Locks (ALL)
2/Unl/PElectric Brake Locks
Lever Locks
Braking Systems
ABS (Anti-Lock Braking System) Air
1/100/P&L
ABS (Anti-Lock Braking System) Hydraulic
Driveline Suspension Control
Clutch Controls
1/100/P&L
Leveling Valves
Electrohydraulics & Controls
Electronic Pedals
2/Unl/PElectrohydraulic Brake Valves (EBV)
Pressure Switches
Hydraulic Braking Solutions
Accumulator Charging Valves
2/Unl/PHydraulic Throttle Controls and Switches
Modulating Brake Valves
Wheel End Solutions
EasyFit™ Slack Adjuster 2/200/P
Caliper Disc Brakes 2/Unl/P
MAXXUS™ Air Disc Brake 1/Unl/P&L
Multiple Disc Brakes 2/Unl/P
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 22, 19 and 17 Air Disc Brake 1/Unl/P&L
TRISTOP™ D Actuator w/ IBV 3/Unl/P
TRISTOP™ D Actuator 2/200/P
UNISTOP™ Actuator 1/100/P
Market Common Application Types
Agriculture
Fertilizer Spreader, Tractor, Heavy Duty Ag
Trailers, Harvester, Sprayer, Skid Loader, Silage
Bagger, Slurry Wagons, Grain Cart
Airport Support
Pushback Tractor, Towing Tugs, Aircraft Tow
Tractor, Refueling Trucks, Food Service Trucks,
Baggage Tractors, De-Icing Equipment,
Runway Clearing Equipment
Construction
All-Terrain Crane, Rough Terrain Crane,
Excavator, Compactor, Wheel Loader, Road
Roller, Motor Grader, Articulated Dump Truck,
Rubber Tire Road Roller, Backhoe Loaders,
Haul Trucks, Scraper Rough Terrain Forklifts,
Trenchers, Drills
Forestry Logging Forwarder, Kidder, Loaders, Yard
Forklifts, Harvesters Fellers
Material Handling
Port Tractor, Rail Yard Spotter, Stevedoring
Tractor, Trailer Spotter, Yard Jockey, Scissor
Lift, Straddle Carrier, Manlift, Forklift, Boom Lift
Telebandlers, Aerial Work Platforms
Mining
Specialized Mining, Excavator, Haul Truck,
Underground Loader, Service Trucks, Wheel
Loaders, Scrapers, Load Haul Dumps,
Personnel Transports, Bolters, Scalers
Municipal
Street Sweeper, Utility Tractor, Utility Trucks,
Tree Trimmers, Dump Trucks, Tow Trucks, Flat
Bed Trucks, Winch Applications
Oil & Gas
Fracturing Trailer, Injecter Heads, Top Drives,
Jack/Lift Boats, Wireline Trucks, Load-On /
Load-Off
Rail
Railcar Mover, Track Layers, Grinders, Platform
Crane, Locomotive Railcars, Ballast Equipment,
Winch Applications

Page 544 of 665 ends

ABS, ELECTRONIC STABILITY CONTROL (ESC),
ROLL STABILITY CONTROL (RSC), OPTIRIDE®,
ONGUARD® AND ONLANE®, COLLECTIVELY
“ELECTRONICS”
Failure of electronic components due to overvoltage
condition, improper grounding, electrostatic discharge
(ESD), improper shielding, electromagnetic interference (EMI), or other wiring or installation issues. Malfunctions and failure codes caused by other electronic subsystem failures (data bus, engine, transmission, dashboard, etc.)

HYDRAULIC COMPONENTS
For certain components, brake fluid DOT3 or DOT4 is
used as the operating medium. Use of any other fluid will void all warranties associated with that component. For hydraulic braking applications the brake fluid is considered a maintenance item. Maintenance intervals are listed in TB- 1367.

COVERAGE LIMITATIONS

PRODUCT DESCRIPTION

ALL PRODUCTS
Any claim beyond 60 days from date of repair will not be accepted or honored under this warranty program.

Products purchased on an incomplete vehicle (glider) are limited to one year, 1/Unl/P .

For vehicles that operate full- or part-time outside of the United States and Canada, a 1-Year/Unlimited Miles parts only (1/Unl/P) will apply.

TOOLBOX PLUS™ DIAGNOSTIC SOFTWARE
Proper diagnostics of WABCO Electronics may require the latest version of TOOLBOX PLUS™. Additional labor due
to use of an outdated version of TOOLBOX™ software
and/or the time to purchase or install the latest version of TOOLBOX PLUS™ are not covered under product
warranty.

TERMS AND CONDITIONS

COVERAGE EXCLUSIONS

PRODUCT DESCRIPTION

ALL PRODUCTS
This Warranty shall not apply to the following, but not limited to: (1) damage to the product or its component
parts caused by incorrect use, installation, maintenance or repair, including without limitation (a) improper fit of mating components or brackets, damaged threads, cut, broken,
chafed, pinched or otherwise damaged wiring (sensors,
harnesses and connectors), (b) sensors damaged during
removal when seized in block, or associated with sensor adjustments/ alignments, and (c) damage resulting from the use or installation of non-genuine WABCO components or
materials; (2) damage to the product, its component parts, or diminished product or component part performance due to incorrect operation, deviation from approved conditions or misapplication; (3) any unauthorized disassembly of the product or its component parts including without limitation (a) obliterated, defaced or missing WABCO or WABCO
name plate, serial numbers or label identifying the device as
a ZF product or WABCO component, (b) changes to sealed
adjusting screws, and (c) opening or attempted repair of non-serviceable components; (4) malfunction
of the component d ue to internal cont amination of t he vehicle system including without limitation (a) water and other contamination damage that is due to the use of a
non-genuine air dryer cartridge or (b) valve failures due to contamination in air system, (5) complaints associated
with noise, (6) damage resulting from corrosion (including oxidation of electrical devices and connections).

AIR DRYERS
Mounting brackets (see vehicle OEM). Desiccant cartridge housing only.

AIR SYSTEM COMPONENTS
Normal wear items; Gladhand seals, dash valve knobs,
valve actuation handles, treadles, pedals.

Page 545 of 665 ends

WARRANTY - MODEL YEAR 2021 VEHICLES
(1) What is Covered by this Commercial Warranty?
ZF CV Systems North America LLC and its North American
subsidiaries and affiliates (ZF) warrant to the owner (“Owner”) that the components listed in this publication, which have been installed by an Original Equipment Manufacturer (“OEM”) as original equipment will be free from defects in material and workmanship. This warranty coverage begins from the original in-service date to the limits provided and runs concurrently with any warranties provided by OEMs and/or any distribution agreements and/or any service contracts that cover the components listed in this publication, if any. If the components listed in this publication are covered by an OEM warranty and/or service contract, then the OEM’s warranty and/ or service contract shall supersede ZF’s warranty and Owner shall comply with all OEM’s warranty and/or service contract requirements for claims under such OEM’s warranty and/or service contract until those agreements expire.

Once those agreements expire and provided the ZF warranty has not expired under the terms stated above, the ZF warranty will be in effect until its expiration date.

Warranty coverage ends at the expiration of the applicable time period from the date of vehicle purchase by the first Owner, or, the applicable mileage limitation, whichever occurs first. Duration of coverage varies by component and vocation as detailed previously in this publication.

Some components are warranted for parts only and the Owner must pay any labor costs associated with the repair or replacement of the component. Other components are warranted for both parts and reasonable labor to repair or replace the subject component.

Additional diagnostic time due to use of an outdated version of TOOLBOX™, time to purchase or install latest version of TOOLBOX™ are the responsibility of the authorized ZF distributor networks and are not covered under product warranty. Components installed as replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty. (2) Designation of Vocational Use Required. To obtain warranty coverage, each Owner must notify ZF through the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the WABCO components have been incorporated prior to the vehicle in- service date. This notification may be accomplished by registering the vehicle through your OEM new truck and/or trailer dealer or with ZF directly. Failure to notify ZF of (I) the intended vocational use of the vehicle or (II) a change in vocational use from that which was originally designated, will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial in- service date. A second Owner and each subsequent Owner
must
also notify ZF as to the intended vocational use of the vehicle. This notification can be sent directly to ZF or through
the OEM new truck and/or trailer dealer. The duration and mileage coverage of this warranty cannot exceed the coverage extended to the first Owner after his or her initial designation of vocational use. Coverage under ZF’
s warranty requires that the application of
products be properly approved pursuant to OEM and ZF, approvals. (3) What is the Cost of this Warranty? There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty? In addition to the items listed on "Coverage Exclusions," this warranty does not cover normal wear and tear, or service items; nor does it cover a component that fails, malfunctions or is damaged as a result of (a) improper handling, storage, installation, adjustment, repair or modification including the use of unauthorized attachments or changes or modification in the vehicle’s configuration, usage, or vocation from that which was originally approved by ZF, (b) accident, fire or other casualty, natural disaster, road debris, negligence, misuse, abuse, or improper use (including loading beyond the specified maximum vehicle weight or altering engine power settings to exceed the brake system capacity),
or (c) improper or insufficient maintenance (including deviation from maintenance intervals, approved lubricants, or lube levels). This warranty does not cover any component or part that is not sold by ZF. (5) To obtain service. If the owner discovers within the applicable coverage period a defect in material or workmanship, the Owner must promptly give notice to either ZF or the dealer from which the vehicle was purchased. To obtain service, the vehicle must be taken to any participating OEM dealer or ZF distributor networks' servicer. The dealer or ZF authorized servicer will inspect the vehicle and contact ZF for an evaluation of the claim. When authorized by ZF, the dealer or ZF authorized servicer will repair or replace during the term of this warranty any defective WABCO component covered by this warranty. (6) Disclaimer of Warranty and Limitation of remedies. TO THE MAXIMUM

EXTENT PERMITTED BY LAW, THE LIMITED WARRANTY SET

FORTH HEREIN IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED, ARISING BY OPERATION OF

LAW OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY

IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE AND/OR WARRANTY FOR HIDDEN OR

LATENT DEFECTS, AND IN NO EVENT WILL ZF OR ANY OF ITS

AFFILIATES BE LIABLE FOR DIRECT, INDIRECT, INCIDENTAL,

PROGRESSIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES OF ANY
KIND.

TERMS AND CONDITIONS

Page 546 of 665 ends

(7) Legal action. Any legal action or claim arising from or related to this Warranty, in contract or otherwise, must be commenced within one year from the accrual of that cause of action, or be barred forever. Any dispute arising in connection with this agreement shall be governed by and construed according to the laws of the State of Michigan and be brought, heard and determined exclusively in either the Circuit Court for the County of Oakland, State of Michigan or the United States District Court for the Eastern District of Michigan. The parties stipulate that the referenced venues are convenient.
(8) Remedy. The exclusive remedy under this warranty shall be the repair or replacement of the defective component at ZF's option. ZF reserves the right to require that all applicable covered components are available and/or returned to ZF
for review
and evaluation. THE MAXIMUM LIABILITY, IF ANY, OF ZF FOR ALL

DAMAGES, INCLUDING WITHOUT LIMITATION CONTRACT

DAMAGES, BREACH OF WARRANTY, NEGLIGENCE, STRICT

LIABILITY, OR OTHER TORT, IS LIMITED TO AN AMOUNT NOT TO EXCEED THE PURCHASE PRICE OF THE PRODUCT and where
indicated in the product and application warranty information above, the inclusion of labor is limited to the standard repair time. THE

PARTIES ACKNOWLEDGE AND AGREE THAT THE LIMITATION

OF DAMAGES PROVISION SET FORTH IN THIS PARAGRAPH

SURVIVES BETWEEN THE ORIGINAL END USER AND ZF EVEN IF

THE EXCLUSIVE REMEDY SET FORTH ABOVE IS DEEMED TO FAIL
OF ITS ESSENTIAL PURPOSE. ZF may change the design or make improvements to its Products without incurring any warranty obligation for previously manufactured Product .
(9) Entire Agreement. This is the entire agreement between ZF and the Owner about warranty and no, ZF employee, or dealer is authorized to make any additional warranty on behalf of ZF unless in writing and signed by an authorized representative of ZF.

Page 547 of 665 ends

About ZF Friedrichshafen AG
ZF is a global technology company and supplies systems for passenger cars, commercial vehicles and industrial technology, enabling the next generation of mobility. ZF allows vehicles to see, think and act. In the four technology domains Vehicle Motion Control, Integrated Safety, Automated Driving, and Electric Mobility, ZF offers comprehensive solutions for established vehicle manufacturers and newly emerging transport and mobility service providers. ZF electrifies different kinds of vehicles. With its products, the company contributes to reducing emissions and protecting the climate.

ZF, which acquired WABCO Holdings Inc. on May 29, 2020, now has 160,000 employees worldwide with approximately 260 locations in 41 countries. In 2019, the two then-independent companies achieved sales of €36.5 billion (ZF) and $3.4 billion (WABCO). For more information, visit: www.wabco-na.com
© 2021
ZF CV Systems North America LLC - All rights reserved - SP1375 / 2.2021 For further product details contact your distributor or the WABCO Customer Care Center at 855-228-3203.

Page 548 of 665 ends

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0012

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This warranty applies only to the cab tubular support and mounting structures and other structural components of the cab of the vehicle model, as identified in the Pierce
specifications for the Fire and Rescue Apparatus.

This warranty does not apply to damage caused by corrosion.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:

Ten (10) Year Structural Integrity
Custom Cab
Ten (10) Years
- or -
100,000 Miles
Warranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:

The Pierce Custom Cab shall be free from structural failures caused by defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

Page 549 of 665 ends

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

Fire and Rescue Apparatus
Coverage:

Ten (10) Year Pro-Rated Paint and Corrosion
Cab
Ten (10) YearsWarranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:

Exterior surfaces of the cab painted by Pierce shall be free from blistering, peeling, corrosion or any other adhesion defect caused by defective manufacturing methods or paint material selection.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0055

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty is applicable to the vehicle in the following percentage costs of warranty repair, if any:

Topcoat Durability & Appearance: Gloss, Color Retention & Cracking
0-72 months 100%
73-96 months 50%
97-120 months 25%
Integrity of Coating System: Adhesion, Blistering/Bubbling 0-36 months 100%
37-84 months 50%
85-120 months 25%
Corrosion: Dissimilar Metal and Crevice
0-36 months 100%
37-48 months 50%
49-72 months 25%
73-120 months 10%
Corrosion Perforation
0-120 months 100%
This limited warranty applies only to exterior paint. Paint on the vehicle's interior is warranted only under the Pierce Basic One Year Limited Warranty.

Items not covered by this warranty include:
(a) Damage from lack of maintenance and cleaning (proper cleaning and maintenance procedures are detailed in the Pierce operation and maintenance manual).
(b) UV paint fade.
(c) Any cab not manufactured by Pierce.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

Page 550 of 665 ends
← All documents from this meeting