Cities Index.
Agenda packet, regular meeting, second session

Laguna Beach City Council
December 9, 2025

Document
Agenda packet, regular meeting, second session
Meeting
December 9, 2025
Body
Laguna Beach City Council
Pages
53
Original file
287.7 MB
Text extracted from the city's file for reading and search. Open the original on lagunabeachcity.primegov.com. That file is the official record.

Figure 3: Proposed West Elevation
The Designee appropriately determined that the proposed deck extension qualified for a categorical exemption from CEQA under the Class 1 exemption for existing facilities. Section 15301 of the State CEQA Guidelines states, in pertinent part:
“Class 1 consists of the operation, repair, maintenance, permitting, leasing, licensing, or minor alteration of existing public or private structures, facilities, mechanical equipment, or topographical features, involving negligible or no expansion of existing or former use. The types of “existing facilities” itemized below are not intended to be all-inclusive of the types of projects which might fall within Class

1. The key consideration is whether the project involves negligible or no expansion of use.

Examples include but are not limited to:
(a) Interior or exterior alterations involving such things as interior partitions, plumbing, …
(e) Additions to existing structures provided that the addition will not result in an increase of more than:

Appeal of the Approval of DR 25-0891 at 31421 Holly Drive December 9, 2025

Page 11 of 17 ends

(1) 50 percent of the floor area of the structures before the addition, or 2,500 square feet, whichever is less; or
(2) 10,000 square feet if:
(A) The project is in an area where all public services and facilities are available to allow for maximum development permissible in the General Plan and (B) The area in which the project is located is not environmentally sensitive.” Here, the proposed project is an approximately 58-square-foot extension of an existing deck on a lot developed with an existing single-family residence, resulting in negligible or no expansion of use, and the lot does not contain environmentally sensitive resources.

Further, as discussed below, none of the exceptions to the CEQA Class 1 exemption apply.

3. The plans were not available at the building counter.

Staff’s Response
The hardcopy plans for the previously approved project, for which a building permit has been issued, are customarily stored in a room at City Hall upon permit issuance. In this instance, the plans had been misfiled within the room, which may explain why they were not immediately located when the Appellant inquired at the public counter. They were subsequently located by the City’s Records Management Coordinator, who confirmed that the plans had been placed in an incorrect location and they were provided for the appellant to review. Both the Applicant and Appellant agree that the plans approved by the DRB showed a 10-foot extension, which is also what is shown on the building permit plans. The elevated deck, which is more than three feet out of grade, cannot be enlarged without administrative design review approval in accordance with LBMC Section 25.05.040(B)(3)(a)(ii), which occurred on June 4, 2025 at a duly noticed ADR hearing.

Furthermore, staff has verified that the Applicant is requesting a two-foot deck extension, not 28 inches as shown the plans prepared for the ADR hearing. This was clarified by the Applicant at the ADR hearing. (Attachment 5 [Transcript], page 2 of 9). After the ADR hearing, the Applicant submitted plans clarifying the deck extension is smaller than originally understood and that match the actual, as-built deck (the corrected plans are included as Attachment 7).

DESIGN REVIEW
Pursuant to the Laguna Beach Municipal Code, the City Council shall conduct a de novo review and is free to deliberate without being limited to the Designee’s findings, but is limited to considering the evidence that was presented to the Designee, including the ADR-approved plans. Because this is a de novo review, staff has prepared suggested findings for the Council’s consideration:

Finding No. 1: Physical improvements and site developments related to the Project are designed and located in a manner in overall consistency with the design review criteria specified in Section 25.05.040(H), as set forth below:

Appeal of the Approval of DR 25-0891 at 31421 Holly Drive December 9, 2025

Page 12 of 17 ends

1. Access. Conflicts between vehicles, pedestrians and other modes of transportation should be minimized by specifically providing for each applicable mode of transportation. Handicapped access shall be provided as required by applicable statutes.

N/A. The proposed deck extension does not change access to the property.

2. Design Articulation: Within the allowable building envelope, the appearance of building and retaining wall mass should be minimized. Articulation techniques including, but not limited to, separation, offsets, terracing and reducing the size of any one element in the structure may be used to reduce the appearance of mass.

Yes. The proposed deck does not add significant additional mass as it is a two-foot cantilevered extension of the previously approved deck area. The expanded deck is located near the middle of the lot on the southfacing elevation of the residence, and would maintain a setback from the south property line ranging from approximately 47 to 60 feet.

3. Design Integrity: Consistency with the applicant’s chosen style of architecture should be achieved by the use of appropriate materials and details. Remodels should be harmonious with the remaining existing architecture.

Yes. The proposed deck extension matches the materials used for the approved portion of the deck.

4. Environmental Context: Development should preserve and, where possible, enhance the city’s scenic natural setting. Natural features, such as existing heritage trees, rock out-cropping, ridgelines and significant watercourses should be protected. Existing terrain should be utilized in the design and grading should be minimized.

Yes. The proposed Project does not require grading as it is a cantilevered extension of a previously approved elevated deck.

5. General Plan Compliance: The development shall comply with all applicable policies of the General Plan, including all of its elements, applicable specific plans, and the certified local coastal program.

Yes. The proposed deck extension is consistent with the applicable General Plan policies as discussed below.

LUE Policy 2.10 Maximize the preservation of coastal and canyon views (consistent with the principle of view equity) from existing properties and minimize blockage of existing public and private views. Best efforts should be made to site new development in locations that minimize adverse impacts on views from public locations (e.g., roads, bluff top trails, visitor-serving facilities, etc.) The project proposes extending an elevated deck two feet beyond the existing approved elevated deck.

Public views are not impacted as the project is above Coast Highway and due to the elevation and placement of the deck in relation to Ocean View Street.

Appeal of the Approval of DR 25-0891 at 31421 Holly Drive December 9, 2025

Page 13 of 17 ends

LUE Policy 3.10 Require building design and siting to be compatible and integrated with natural topographic features, minimize significant alteration of natural topography or other significant on-site resources, and protect public views as specified in the Design Guidelines and Landscape and Scenic Highways Resource Document by maintaining the low-profile character of structures. Require use of appropriate landscaping, special architectural treatments, and siting considerations for projects visible from major highways and arterial streets. Best efforts should be made to site new development in locations that minimize adverse impacts on views from public locations (e.g., roads, bluff-top trails, visitor-serving facilities, etc.)
The Project does not require grading and public views are not impacted as the Project is not in close proximity and visible from a public viewing location such as a trail, park, or lookout. The architecture complies with the design integrity and articulation design review criteria as discussed above.

LUE Policy 7.3 Design and site new development to protect natural and environmentally sensitive resources, such as areas of unique scenic quality, public views, and visual compatibility with surrounding uses and to minimize natural landform alterations. (Same as Policy 10.2.) GOAL: Protect, preserve, and enhance the community’s natural resources.

The project site does not include environmentally sensitive areas and public views are not impacted as the project is not visible from Coast Highway and due to the elevation and placement of the deck in relation to Ocean View Street.

LUE Policy 10.2 Design and site new development to protect natural and environmentally sensitive resources such as areas of unique scenic quality, public views, and visual compatibility with surrounding uses and to minimize landform alterations. (Same as Policy 7.3) GOAL: Ensure that proposals for new development, subdivisions, and major remodels are sufficiently evaluated to protect public health and safety and natural resources.

The project site does not include environmentally sensitive areas and public views are not impacted as the project is not visible from a public viewing location such as a trail, park, or lookout and due to the elevation and placement of the deck in relation to Ocean View Street.

6. Historic Preservation: Destruction or alteration to historic resources should be avoided whenever possible. See Chapter 25.45 for more information.

N/A. The project site does not contain historic structures within its boundaries or in the immediate vicinity that would be affected by the proposed Project.

7. Landscaping: Landscaping shall be incorporated as an integrated part of the structure’s design and relate harmoniously to neighborhood and community landscaping themes. View equity shall be an important consideration in the landscape design. The relevant landscaping guidelines contained in the City’s “Landscape and Scenic Highways Resource Document” should be incorporated, as appropriate, in the design and planned maintenance of proposed landscaping.

Appeal of the Approval of DR 25-0891 at 31421 Holly Drive December 9, 2025

Page 14 of 17 ends

N/A. No landscaping is proposed with the Project.

8. Lighting and Glare: Adequate lighting for individual and public safety shall be provided in a manner which does not significantly impact neighboring properties. Reflective materials and appurtenances that cause glare or a negative visual impact (e.g., skylights, white rock roofs, high-gloss ceramic tile roofs, reflective glass, etc.) should be avoided or mitigated to a level of insignificance in those locations where those surfaces are visible from neighboring properties.

Yes. No lighting is proposed with the Project and the proposed railings do not result in glare impacts.

9. Neighborhood Compatibility: Development shall be compatible with the existing development in the neighborhood and respect neighborhood character. Neighborhood character is the sum of the qualities that distinguish areas within the City, including historical patterns of development (e.g., structural heights, mass, scale or size), village atmosphere, landscaping themes and architectural styles.

Yes. The proposed mid-level elevated deck is compatible with neighboring decks for homes between Holly Drive and Ocean View Street, which commonly feature elevated decks along the south building elevations, oriented to capture ocean views.

10. Pedestrian Orientation: Commercial development design shall enhance and encourage pedestrian uses.

Incorporation of articulated building masses, compact open spaces and courtyards, mixed use developments, use of landscaping as part of design, and orientation to pedestrian access should be maximized.

N/A. This criterion is related to commercial projects.

11. Privacy: The placement of activity areas (e.g., decks, picture windows and ceremonial or entertainment rooms) in locations that would result in a substantial invasion of privacy of neighboring properties should be minimized.

Yes. The proposed deck extension does not result in a substantial privacy impact for neighboring properties as the deck is oriented towards the ocean, is similar to neighboring decks, and does not extend the entire width of the home. At the middle floor level, the habitable area directly adjacent to the deck is approximately 42 feet wide, while the deck measures 28’-6” wide.

12. Public Art: Public art is encouraged and shall be displayed where feasible or required by the Art in Public Places ordinance.

N/A. This criterion is related to commercial projects.

13. Sign Quality: Signs shall be incorporated into the architecture of the structure and shall be made of high quality materials, be simple in design and be visually compatible with the surrounding physical environment in terms of color, scale and size. Use of natural materials in the construction of signs is encouraged.

Appeal of the Approval of DR 25-0891 at 31421 Holly Drive December 9, 2025

Page 15 of 17 ends

N/A. This criterion is related to commercial projects.

14. Sustainability: New development should consider architecture and building practices which minimize environmental impacts and enhance energy efficiency by: (a) reducing energy needs of buildings by proper site and structural design; (b) increasing the building’s ability to capture or generate energy; (c) using low-impact, sustainable and recycled building materials; (d) using the latest Best Management Practices regarding waste and water management; and (e) reducing site emissions.

Yes. The proposed Project will be required to meet Title 24 requirements related to energy efficiency and to recycle at least 65 percent of construction materials per the California Building Code.

15. Swimming Pools, Spas, and Water Features: Swimming pools, spas and water features shall be located, designed and constructed where: (a) geology conditions allow; (b) noise produced by circulatory mechanical pumps and equipment is mitigated; and (c) any associated fencing or other site improvements are compatible with neighboring properties.

N/A. The Project does not involve a new swimming pool or spa.

16. View Equity: The development, including its landscaping, shall be designed to protect existing views from neighboring properties without denying the subject property the reasonable opportunity to develop as described and illustrated in the City’s “Design Guidelines.” The “Design Guidelines” are intended to balance preservation of views with the right to develop property.

Yes. The Project does not result in view impacts that substantially degrade the existing views of the coast from neighboring properties. Properties abutting the Project to east and west are similarly oriented to the south to capture ocean views. As such, the deck extension does not significantly encroach into scenic viewsheds enjoyed by neighboring properties.

Finding No. 2. The physical improvements and site developments related to the Project are designed and located in a manner in overall consistency with all other applicable design guidelines.

N/A. No additional design guidelines apply to this Project.

Finding No. 3. The physical improvements and site developments related to the Project are characterized by appropriately scaled development, diverse and unique architectural designs, pedestrian orientation, and sensitivity to the natural conditions of the site.

Yes, the Project is appropriately scaled as discussed under the design articulation and neighborhood compatibility design review criteria above.

Finding No. 4. The project is consistent with any specific plan or any other specific zoning design review criteria.

N/A. The proposed Project is not located in a specific plan or subject to additional design review criteria.

Appeal of the Approval of DR 25-0891 at 31421 Holly Drive December 9, 2025

Page 16 of 17 ends

RECOMMENDATION
Adopt the Resolution denying the appeal and sustaining the Designee’s approval of Design Review 25- 0891, and finding the Project exempt from CEQA under State CEQA Guidelines Section 15301.

FINANCIAL ANALYSIS
The recommended action has no financial impact to the budget.

ENVIRONMENTAL ANALYSIS
The Project is categorically exempt from CEQA pursuant to Section 15301, Class 1, Existing Facilities, in that the Project consists of the repair, maintenance, or minor alteration of existing structures or topographical features, involving negligible or no expansion of existing or former use. Here, the Project includes a 58-square-foot deck addition to an existing elevated deck associated with an existing singlefamily residence. Further, none of the exceptions outlined in CEQA Guidelines section 15300.2 apply. The project site does not contain any environmentally sensitive areas, in that the site is fully developed with an existing single-family residence with an attached one-car garage, patios, and ornamental landscaping, and is surrounded on all sides by public streets and developed properties, and the City’s environmentally sensitive maps do not identify any such areas on-site or within the immediate Project vicinity. There will be no cumulative impact resulting from successive projects of the same type in the same place, over time in that the Project includes a scope of work that is consistent with the allowed uses in the residential lowdensity zone, and elevated decks are common features in the area. There are no unusual circumstances resulting in a significant impact on the environment. There will be no damage to scenic resources, including trees, historic buildings, rock outcroppings or similar resources, within a highway officially designated as a state scenic highway. The project is not located on a hazardous waste site or any other site included on a list compiled pursuant to Government Code section 65962.5. The project will not result in significant adverse impacts to historical resources as defined by CEQA in that there are no such resources on site or within the immediate vicinity that would be impacted by the Project. Consequently, additional environmental analysis is not necessary to meet the requirements of the CEQA.

ATTACHMENTS

1. City Council Resolution (Pgs. 18-31)

2. Appeal (Pgs. 32-51)

3. June 4, 2025 Admin CDD Meeting Plans (Pgs. 52-55)

4. June 4, 2025 Admin CDD Meeting Public Comments (Pgs. 56-86)

5. June 4, 2025 Admin CDD Meeting Transcript (Pgs. 87-95)

6. Public Notice (Pg. 96)

7. Corrected Plans (Pgs. 97-100)

8. February 23, 2023 DRB Staff Report (Pgs. 101-117)

9. February 23, 2023 DRB Plans (Pgs. 118-133)

10. February 23, 2023 DRB Meeting Minutes (Pgs. 134-135)

11. February 23, 2023 DRB Public Correspondence (Pg. 136)

12. Certified Staking Plan from February 23, 2023 DRB Meeting (Pg. 137)

13. Order of Testimony (Pg. 138)
Appeal of the Approval of DR 25-0891 at 31421 Holly Drive December 9, 2025

Page 17 of 17 ends

Submitted By: Matthew Schneider Approved: .David A Kiff Matthew Schneider, Director of
Community Development
Dave Kiff, City Manager
Report Prepared By: Coordinated With:

Daniel Latham, Associate Planner Anthony Viera, Deputy Director of Community Development
Patrick Donegan, Assistant City Attorney
RESOLUTION NO. 25.XXX

A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF

LAGUNA BEACH, CALIFORNIA, UPHOLDING THE DECISION
OF THE COMMUNITY DEVELOPMENT DIRECTOR’S
DESIGNEE TO APPROVE DESIGN REVIEW 25-0891 FOR AN
ELEVATED DECK ADDITION AT 31421 HOLLY DRIVE IN
THE R-1, RESIDENTIAL LOW-DENSITY ZONE AND

FINDING THE ACTION EXEMPT FROM THE

CALIFORNIA ENVIRONMENTAL QUALITY ACT

PURSUANT TO STATE CEQA GUIDELINES SECTION
15301
WHEREAS, the applicant, Dave Frith (“Applicant”) sought Design Review (“DR”) 25- 0891 for an elevated deck addition at 31421 Holly Drive in the R-1 (Residential Low Density) zone (the “Project”). The Project requires ADR under Laguna Beach Municipal Code (“LBMC”) Section 25.05.040(B)(3)(a)(ii); and
WHEREAS, on June 4, 2025, the Community Development Director’s Designee (the “Designee”) held a duly-noticed public hearing on the Project, received public testimony, and approved DR 25-0891 and found the Project categorically exempt from the California Environmental Quality Act (“CEQA”) under State CEQA Guidelines Section 15301 (Class 1); and WHEREAS, on June 18, 2025 an appeal was filed by the neighboring property owner, Lori Austin (the “Appeal”); and
WHEREAS, on August 12, 2025 City Council held a duly-noticed public hearing on the Appeal and continued the public hearing to September 23, 2025; and WHEREAS, on September 23, 2025 City Council held a duly-noticed public hearing on the Appeal and continued the public hearing to October 28, 2025; and WHEREAS, on October 28, 2025 City Council held a duly-noticed public hearing on the Appeal and continued the public hearing to November 18, 2025; and WHEREAS, on November 18, 2025 City Council held a duly-noticed public hearing on Attachment1
18 -2- Reso. #
the Appeal and continued the public hearing to December 9. 2025; and WHEREAS, on December 9. 2025 City Council held a duly-noticed public hearing on the Appeal and carefully considered the oral and documentary evidence and arguments presented.

NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF LAGUNA BEACH DOES RESOLVE:

SECTION 1. The recitals set forth above are true and correct and are incorporated into this Resolution by this reference.

SECTION 2. The City Council hereby makes the following findings in response to the grounds for appeal stated in the Appellant’s notice of Appeal:

1. The proposed deck extension was incorrectly described as either a 24- or 28-inch extension. The deck was constructed with an approximately four-foot extension.

City Council Finds:

The constructed deck extends two feet beyond the 10-foot deck dimension originally staked for the DRB hearing held on February 23, 2023. The certified staking plan prepared for the DRB hearing is provided as Attachment 12 to the agenda report. In response to this discrepancy, the applicant submitted an Administrative Design Review application to address the additional two feet beyond the originally proposed 10-foot deck, resulting in a total depth of 12 feet from the rear of the residence (58 square feet of additional deck area). As further clarification, the applicant also submitted a video to staff measuring the depth of the deck to be 144 inches (12 feet). Furthermore, the surveyor of record will verify that the deck was built per plan. This verification will be required before the City will pass a final building inspection.
19 -3- Reso. #

2. There are CEQA impacts from alterations and excavations and topographical features.

City Council Finds:

The construction of the proposed elevated deck addition does not require any grading. While excavation is required for the installation of support posts, the proposed two-foot extension to the previously approved deck will not require additional posts, as it is designed to cantilever.

The Designee appropriately determined that the proposed deck extension qualified for a categorical exemption from CEQA under the Class 1 exemption for existing facilities.

Section 15301 of the State CEQA Guidelines states, in pertinent part:
“Class 1 consists of the operation, repair, maintenance, permitting, leasing, licensing, or minor alteration of existing public or private structures, facilities, mechanical equipment, or topographical features, involving negligible or no expansion of existing or former use. The types of “existing facilities” itemized below are not intended to be all-inclusive of the types of projects which might fall within Class 1. The key consideration is whether the project involves negligible or no expansion of use.

Examples include but are not limited to:
(a) Interior or exterior alterations involving such things as interior partitions, plumbing,
…
(e) Additions to existing structures provided that the addition will not result in an increase of more than:
(1) 50 percent of the floor area of the structures before the addition, or 2,500 square feet, whichever is less; or
(2) 10,000 square feet if:
(A) The project is in an area where all public services and facilities are available to allow for maximum development permissible in the General Plan and
(B) The area in which the project is located is not environmentally 20 -4- Reso. #
sensitive.”
Here, the proposed project is an approximately 58-square-foot extension of an existing deck on a lot developed with an existing single-family residence, resulting in negligible or no expansion of use, and the lot does not contain environmentally sensitive resources.

3. The plans were not available at the building counter.

City Council Finds:

The hardcopy plans for the previously approved project, for which a building permit has been issued, are customarily stored in a room at City Hall upon permit issuance. In this instance, the plans had been misfiled within the room, which may explain why they were not immediately located when the Appellant inquired at the public counter. They were subsequently located by the City’s Records Management Coordinator, who confirmed that the plans had been placed in an incorrect location and they were provided for the appellant to review. Both the Applicant and Appellant agree that the plans approved by the DRB showed a 10-foot extension, which is also what is shown on the building permit plans. The elevated deck, which is more than three feet out of grade, cannot be enlarged without administrative design review approval in accordance with LBMC Section

25.05.040(B)(3)(a)(ii), which occurred on June 4, 2025 at a duly noticed ADR hearing.

Furthermore, staff has verified that the Applicant is requesting a two-foot deck extension, not 28 inches as shown the plans prepared for the ADR hearing. This was clarified by the 21 -5- Reso. #
Applicant at the ADR hearing. (Attachment 5 of the agenda report [Transcript], page 2 of 9). After the ADR hearing, the Applicant submitted plans clarifying the deck extension is smaller than originally understood (the revised plans are included as Attachment 7 to the agenda report).

SECTION 3. The City Council hereby makes the following findings with respect to Design Review 25-0891:

Finding No. 1: Physical improvements and site developments related to the Project are designed and located in a manner in overall consistency with the design review criteria specified in Section 25.05.040(H), as set forth below:

1. Access. Conflicts between vehicles, pedestrians and other modes of transportation should be minimized by specifically providing for each applicable mode of transportation.

Handicapped access shall be provided as required by applicable statutes.

N/A. The proposed deck extension does not change access to the property.

2. Design Articulation: Within the allowable building envelope, the appearance of building and retaining wall mass should be minimized. Articulation techniques including, but not limited to, separation, offsets, terracing and reducing the size of any one element in the structure may be used to reduce the appearance of mass.

Yes. The proposed deck does not add significant additional mass as it is a two-foot cantilevered extension of the previously approved deck area. The expanded deck is located near the middle of the lot on the south-facing elevation of the residence, and would maintain a setback from the south property line ranging from approximately 47 to 60 feet.

3. Design Integrity: Consistency with the applicant’s chosen style of architecture should 22 -6- Reso. #
be achieved by the use of appropriate materials and details. Remodels should be harmonious with the remaining existing architecture.

Yes. The proposed deck extension matches the materials used for the approved portion of the deck.

4. Environmental Context: Development should preserve and, where possible, enhance the city’s scenic natural setting. Natural features, such as existing heritage trees, rock outcropping, ridgelines and significant watercourses should be protected. Existing terrain should be utilized in the design and grading should be minimized.

Yes. The proposed Project does not require grading as it is a cantilevered extension of a previously approved elevated deck.

5. General Plan Compliance: The development shall comply with all applicable policies of the General Plan, including all of its elements, applicable specific plans, and the certified local coastal program.

Yes. The proposed deck extension is consistent with the applicable General Plan policies as discussed below.

LUE Policy 2.10 Maximize the preservation of coastal and canyon views (consistent with the principle of view equity) from existing properties and minimize blockage of existing public and private views. Best efforts should be made to site new development in locations that minimize adverse impacts on views from public locations (e.g., roads, bluff top trails, visitor-serving facilities, etc.) The project proposes extending an elevated deck two feet beyond the existing approved elevated deck. Public views are not impacted as the project is 23 -7- Reso. #
above Coast Highway and due to the elevation and placement of the deck in relation to Ocean View Street.

LUE Policy 3.10 Require building design and siting to be compatible and integrated with natural topographic features, minimize significant alteration of natural topography or other significant on-site resources, and protect public views as specified in the Design Guidelines and Landscape and Scenic Highways Resource Document by maintaining the low-profile character of structures. Require use of appropriate landscaping, special architectural treatments, and siting considerations for projects visible from major highways and arterial streets. Best efforts should be made to site new development in locations that minimize adverse impacts on views from public locations (e.g., roads, bluff-top trails, visitor-serving facilities, etc.) The Project does not require grading and public views are not impacted as the Project is not in close proximity and visible from a public viewing location such as a trail, park, or lookout. The architecture complies with the design integrity and articulation design review criteria as discussed above.

LUE Policy 7.3 Design and site new development to protect natural and environmentally sensitive resources, such as areas of unique scenic quality, public views, and visual compatibility with surrounding uses and to minimize natural landform alterations. (Same as Policy 10.2.) GOAL: Protect, preserve, and enhance the community’s natural resources.

The project site does not include environmentally sensitive areas and public views are not impacted as the project is not visible from Coast Highway and due to 24 -8- Reso. #
the elevation and placement of the deck in relation to Ocean View Street.

LUE Policy 10.2 Design and site new development to protect natural and environmentally sensitive resources such as areas of unique scenic quality, public views, and visual compatibility with surrounding uses and to minimize landform alterations. (Same as Policy 7.3) GOAL: Ensure that proposals for new development, subdivisions, and major remodels are sufficiently evaluated to protect public health and safety and natural resources.

The project site does not include environmentally sensitive areas and public views are not impacted as the project is not visible from a public viewing location such as a trail, park, or lookout and due to the elevation and placement of the deck in relation to Ocean View Street.

6. Historic Preservation: Destruction or alteration to historic resources should be avoided whenever possible. See Chapter 25.45 for more information.

N/A. The project site does not contain historic structures within its boundaries or in the immediate vicinity that would be affected by the proposed Project.

7. Landscaping: Landscaping shall be incorporated as an integrated part of the structure’s design and relate harmoniously to neighborhood and community landscaping themes.

View equity shall be an important consideration in the landscape design. The relevant landscaping guidelines contained in the City’s “Landscape and Scenic Highways Resource Document” should be incorporated, as appropriate, in the design and planned maintenance of proposed landscaping.

N/A. No landscaping is proposed with the Project.

8. Lighting and Glare: Adequate lighting for individual and public safety shall be 25 -9- Reso. #
provided in a manner which does not significantly impact neighboring properties. Reflective materials and appurtenances that cause glare or a negative visual impact (e.g., skylights, white rock roofs, high-gloss ceramic tile roofs, reflective glass, etc.) should be avoided or mitigated to a level of insignificance in those locations where those surfaces are visible from neighboring properties.

Yes. No lighting is proposed with the Project and the proposed railings do not result in glare impacts.

9. Neighborhood Compatibility: Development shall be compatible with the existing development in the neighborhood and respect neighborhood character. Neighborhood character is the sum of the qualities that distinguish areas within the City, including historical patterns of development (e.g., structural heights, mass, scale or size), village atmosphere, landscaping themes and architectural styles.

Yes. The proposed mid-level elevated deck is compatible with neighboring decks for homes between Holly Drive and Ocean View Street, which commonly feature elevated decks along the south building elevations, oriented to capture ocean views.

10. Pedestrian Orientation: Commercial development design shall enhance and encourage pedestrian uses. Incorporation of articulated building masses, compact open spaces and courtyards, mixed use developments, use of landscaping as part of design, and orientation to pedestrian access should be maximized.

N/A. This criterion is related to commercial projects.

11. Privacy: The placement of activity areas (e.g., decks, picture windows and ceremonial or entertainment rooms) in locations that would result in a substantial invasion of privacy of 26 -10- Reso. #
neighboring properties should be minimized.

Yes. The proposed deck extension does not result in a substantial privacy impact for neighboring properties as the deck is oriented towards the ocean, is similar to neighboring decks, and does not extend the entire width of the home. At the middle floor level, the habitable area directly adjacent to the deck is approximately 42 feet wide, while the deck measures 28’-6” wide.

12. Public Art: Public art is encouraged and shall be displayed where feasible or required by the Art in Public Places ordinance.

N/A. This criterion is related to commercial projects.

13. Sign Quality: Signs shall be incorporated into the architecture of the structure and shall be made of high quality materials, be simple in design and be visually compatible with the surrounding physical environment in terms of color, scale and size. Use of natural materials in the construction of signs is encouraged.

N/A. This criterion is related to commercial projects.

14. Sustainability: New development should consider architecture and building practices which minimize environmental impacts and enhance energy efficiency by: (a) reducing energy needs of buildings by proper site and structural design; (b) increasing the building’s ability to capture or generate energy; (c) using low-impact, sustainable and recycled building materials; (d) using the latest Best Management Practices regarding waste and water management; and (e) reducing site emissions.

Yes. The proposed Project will be required to meet Title 24 requirements related to energy efficiency and to recycle at least 65 percent of construction materials per the 27 -11- Reso. #
California Building Code.

15. Swimming Pools, Spas, and Water Features: Swimming pools, spas and water features shall be located, designed and constructed where: (a) geology conditions allow; (b) noise produced by circulatory mechanical pumps and equipment is mitigated; and (c) any associated fencing or other site improvements are compatible with neighboring properties.

N/A. The Project does not involve a new swimming pool or spa.

16. View Equity: The development, including its landscaping, shall be designed to protect existing views from neighboring properties without denying the subject property the reasonable opportunity to develop as described and illustrated in the City’s “Design Guidelines.” The “Design Guidelines” are intended to balance preservation of views with the right to develop property.

Yes. The Project does not result in view impacts that substantially degrade the existing views of the coast from neighboring properties. Properties abutting the Project to east and west are similarly oriented to the south to capture ocean views. As such, the deck extension does not significantly encroach into scenic viewsheds enjoyed by neighboring properties.

Finding No. 2. The physical improvements and site developments related to the Project are designed and located in a manner in overall consistency with all other applicable design guidelines.

N/A. No additional design guidelines apply to this Project.

Finding No. 3. The physical improvements and site developments related to the Project are characterized by appropriately scaled development, diverse and unique architectural designs, 28 -12- Reso. #
pedestrian orientation, and sensitivity to the natural conditions of the site.

Yes, the Project is appropriately scaled as discussed under the design articulation and neighborhood compatibility design review criteria above.

Finding No. 4. The project is consistent with any specific plan or any other specific zoning design review criteria.

N/A. The proposed Project is not located in a specific plan or subject to additional design review criteria.

SECTION 4. Based on its review of the entire record before it, the City Council hereby finds and determines that the Project is categorically exempt from the California Environmental Quality Act (“CEQA”) pursuant to Section 15301 - Existing Facilities, in that the Project consists of the repair, maintenance, or minor alteration of existing structures or topographical features, involving negligible or no expansion of existing or former use. Here, the Project includes a 58- square-foot deck addition to an existing elevated deck associated with an existing single-family residence. Further, none of the exceptions outlined in CEQA Guidelines section 15300.2 apply.

The project site does not contain any environmentally sensitive areas, in that the site is fully developed with an existing single-family residence with an attached one-car garage, patios, and ornamental landscaping, and is surrounded on all sides by public streets and developed properties, and the City’s environmentally sensitive maps do not identify any such areas on-site or within the immediate Project vicinity. There will be no cumulative impact resulting from successive projects of the same type in the same place, over time in that the Project includes a scope of work that is consistent with the allowed uses in the residential low-density zone, and elevated decks are common features in the area. There are no unusual circumstances resulting in a significant impact 29 -13- Reso. #
on the environment. There will be no damage to scenic resources, including trees, historic buildings, rock outcroppings or similar resources, within a highway officially designated as a state scenic highway. The project is not located on a hazardous waste site or any other site included on a list compiled pursuant to Government Code section 65962.5. The project will not result in significant adverse impacts to historical resources as defined by CEQA in that there are no such resources on site or within the immediate vicinity that would be impacted by the Project.

Consequently, additional environmental analysis is not necessary to meet the requirements of the CEQA.

SECTION 5. The City Council hereby upholds the Designee’s decision on Design Review 25-0891.

ADOPTED this 9th day of December, 2025.

Alex Rounaghi, Mayor
ATTEST:

Ann Marie McKay, City Clerk
30 -14- Reso. #
I, Ann Marie McKay, City Clerk of the City of Laguna Beach, certify that the foregoing Resolution No. 25.XXX was duly adopted at a regular meeting of the City Council of said City held on December 9, 2025, by the following vote:

AYES: COUNCILMEMBERS:

NOES: COUNCILMEMBERS:

ABSENT: COUNCILMEMBERS:

City Clerk, City of Laguna Beach, CA
31 Attachment 2
32 33
34 35
36 37
38 39
40 41
42 43
44 45
46 47
48 49
50 51

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022
PERMIT PLAN CHECK 03.23.2023
PERMIT SET 05.08.2023
DELTA 4 08.06.2024
DELTA 5 01.02.2025
DELTA 6 04.29.2025

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110

PROJECT SUMMARY TABLES
USE SFR ZONE R1 LOT SLOPE (%) 27%

ZONING STANDARDS

DESCRIPTION REQUIRED EXISTING PROPOSED CONFORMS
LOT AREA 6,000 S.F. 6,874 S.F. NO CHANGE YES
LOT WIDTH 70'-0" 54'-5" NO CHANGE NO
LOT DEPTH 80'-0" 126'-2" NO CHANGE YES
MAX BUILDING HEIGHT 30'-0" 20'-2" NO CHANGE YES
MAX HEIGHT FROM CURB 15'-0" 9'-8" NO CHANGE YES
SETBACKS:

FRONT YARD
5'-0" GARAGE
10'-0" HOUSE
7'-1" GARAGE
26'-11" HOUSE NO CHANGE YES
REAR YARD 20'-0" 50'-0" NO CHANGE YES
SIDE YARDS (E) 54.22' FRONT + 60' REAR = 114.22'
/ 2 = 57.11' AVERAGE WIDTH
* 20%=11.42' TOTAL S.Y.S.B. (11'-5")
4'-4" (4'-9" EXISTING) NO CHANGE YES
SIDE YARDS (W) 7'-1" NO CHANGE YES

LOT COVERAGE
(BSC)
BSC %: 35 + (8000-6874) x 9
/ 4000 = 38%
2,124 S.F. 2,149 S.F. YES 31% 31%

LANDSCAPE OPEN SPACE
1,532 S.F. 4,316 S.F. 4,037 S.F. YES 22% MIN. 63% 59%
PARKING 2 COVERED SPACES 1 COVERED NO CHANGE NO

PROJECT DATA

DESCRIPTION EXISTING PROPOSED TOTAL REMODEL
LIVING AREA:

BASEMENT 602 S.F. 351 S.F. 953 S.F. 140 S.F.

MAIN LEVEL 1,273 S.F. 409 S.F. 1,682 S.F. 200 S.F.

TOTAL 1,875 S.F. 760 S.F. 2,635 S.F. 340 S.F.

GARAGE 279 S.F. NO CHANGE 279 S.F.

ELEVATED DECK 0 S.F. 367 S.F. 367 S.F.

MECHANICAL / STORAGE 351 S.F. -351 S.F. 0 S.F.

DEMOLITION EXISTING REMOVED REMAINING DEMO TOTAL
FLOOR AREA:

BASEMENT 602 S.F. 0 S.F. 602 S.F. 0%
MAIN LEVEL 1,273 S.F. 0 S.F. 1,273 S.F. 0%
ROOF AREA 2,124 S.F. 374 S.F. 1,750 S.F. 18%
TOTAL EXTERIOR WALL 337'-6" L.F. 110'-3" L.F. 227'-3" L.F. 33% FOUNDATION 197'-4" L.F. 49'-10" L.F. 147'-6" L.F. 25%
TOTAL WALL + ROOF +

FOUNDATION
25%

SITE WORK

GRADING (CUBIC YARDS) OUTSIDE BUILDING

FOOTPRINT

INSIDE BUILDING

FOOTPRINT
TOTAL
CUT 0 CUBIC YARDS 0 CUBIC YARDS 0 CU. YD.

FILL 0 CUBIC YARDS 0 CUBIC YARDS 0 CU. YD.

NET EXPORT 0 CUBIC YARDS 0 CUBIC YARDS 0 CU. YD.

IMPERVIOUS SURFACES
LOT AREA % OF LOT AREA

EXISTING PROPOSED EXISTING PROPOSED
STRUCTURE 2,124 S.F. 2,149 S.F. 31% 31%

HARDSCAPE
(INCL. DRIVEWAY) 430 S.F. 702 S.F. 6% 10%
TOTAL 2,554 S.F. 2,851 S.F. 37% 41%

EXTERIOR BUILDING LIGHTING
EXISTING EGRESS DOORS 3 PROPOSED EGRESS DOORS 6
EXISTING FIXTURE COUNT 3 PROPOSED FIXTURE COUNT 15

FIXTURE TYPE WATTAGE LUMUNES QUANTITY COMMENTS
RECESSED STAIR LIGHT 0 365 10
WALL SCONCE 3 365 4
RECESSED SOFFIT LIGHT 0 365 1
TOTAL 15

LANDSCAPE LIGHTING
EXISTING FIXTURE COUNT 10 PROPOSED FIXTURE COUNT 10

FIXTURE TYPE WATTAGE LUMUNES QUANTITY COMMENTS
GARDEN LIGHT 10 365 10
TOTAL 10
COMBINED TOTAL 25

ARCHITECT

BEACH BUS STUDIOS
349 THIRD STREET
LAGUNA BEACH, CA 92651
(949) 376-3080
CONTACT: DAVE FRITH
[email protected]

STRUCTURAL ENGINEER
CORE STRUCTURE, INC.
23172 PLAZA POINTE DR., SUITE 145
LAGUNA HILLS, CA 92653
(949) 954-7244
CONTACT: AMIR DEIHIMI
[email protected]
TITLE 24 ENERGY CONSULTANT

CARSTAIRS ENERGY CALCULATIONS
2238 BAYVIEW HEIGHTS DR, SUITE E
LOS OSOS, CA 93402
(805) 904-9048
CONTACT: TIMOTHY CARSTAIRS
[email protected]

PROJECT CONSULTANTS

PROJECT ADDRESS
31421 HOLLY DR
LAGUNA BEACH, CA 92651
OWNERS

AINA & GORDON MCBEAN
(949) 376-3080
LEGAL DESCRIPTION N TR 713 BLK LOT 205
ASSESSOR PARCEL NO. (APN) 056-061-16
PARCEL ID NO. (PIN) 1036

COUNTY OF ORANGE
ZONE DISTRICT R1

CONSTRUCTION TYPE V-B

BUILDING DOES NOT HAVE A FIRE SPRINKLER SYSTEM

PROJECT INFORMATION

SUMMARY OF EXTERIOR ARCHITECTURAL IMPROVEMENTS

1. ENCLOSE OUTDOOR PATIO, CONVERT TO 396 S.F. OF HABITABLE AREA

2. MAIN LEVEL DECK ADDITION OF 300 S.F.

3. THREE BAY WINDOWS

4. REPLACE AT GRADE EXTERIOR STAIR AT SIDE YARD AND ENTRY

5. NEW STANDING SEAM METAL ROOF TO REPLACE EXISTING

6. NEW HORIZONTAL SIDING

7. NEW DOORS AND WINDOW TO REPLACE EXISTING

8. NEW ROOF AT EXISTING ENTRYWAY

9. NEW NEW 6'Ø PRE-FABRICATED, FREESTANDING, SELF CONTAINED JACUZZI.

10. NEW AC COMPRESSOR

10.5 67 SF ADDITION TO AN EXISTING APPROVED 300 SF DECK

SUMMARY OF INTERIOR ARCHITECTURAL IMPROVEMENTS

11. KITCHEN AND BATHROOM REMODEL

12. REPLACEMENT OF EXISTING WIRING FOR NEW FIXTURES

13. ADDITIONAL DRYWALL REMOVAL TO MATCH DEMO CALCS REV. 1 NOTE:

APPROVED THROUGH DESIGN REVIEW 22-2245 & VARIANCE 22-2266

SCOPE OF WORK

COVER SHEET
A001

SHEET INDEX

GENERAL NOTES

ARCHITECTURAL
A001 COVER SHEET
A002 CAL GREEN (NOT USED)
A003 CAL GREEN (NOT USED)
A004 FIRE DEPARTMENT SITE ACCESS PLAN (NOT USED)
A005 CONSTRUCTION STAGING PLAN (NOT USED)
A006 SITE PLANS
AD00 BASEMENT & GARAGE DEMOLITION PLANS (NOT USED)
AD01 MAIN LEVEL DEMOLITION PLAN (NOT USED)
A100 BASEMENT & GARAGE NEW WORK PLANS (NOT USED)
A101 MAIN LEVEL NEW WORK PLAN
A150 BASEMENT & GARAGE POWER PLANS (NOT USED)
A151 MAIN LEVEL POWER PLAN (NOT USED)
A200 BASEMENT & GARAGE REFLECTED CEILING PLANS (NOT USED) A201 MAIN LEVEL REFLECTED CEILING PLAN (NOT USED)
A300 ROOF PLANS (NOT USED)
A500 EXTERIOR ELEVATIONS (NOT USED)
A501 EXTERIOR ELEVATIONS (NOT USED)
A502 EXTERIOR ELEVATIONS
A503 EXTERIOR ELEVATIONS (NOT USED)
A600 BUILDING SECTIONS (NOT USED)
A601 BUILDING SECTIONS (NOT USED)
A700 STAIR DETAILS (NOT USED)
A800 EXTERIOR DETAILS (NOT USED)
A900 DOOR & WINDOW SCHEDULES (NOT USED)
A901 DOOR & WINDOW DETAILS (NOT USED)
TITLE 24
T-24.1 T-24 ENERGY ANALYSIS (NOT USED)
T-24.2 T-24 ENERGY ANALYSIS (NOT USED)
T-24.3 T-24 ENERGY ANALYSIS (NOT USED)

STRUCTURAL
S-0.10 GENERAL NOTES & REQUIREMENTS (NOT USED)
S-0.11 GENERAL NOTES & REQUIREMENTS (NOT USED)
S-0.20 TYPICAL DETAILS (NOT USED)
S-1.0 FOUNDATION PLAN (NOT USED)
S-2.0 FRAMING PLAN (NOT USED)
SD1.0 FOUNDATION DETAILS (NOT USED)
SD1.1 FOUNDATION DETAILS (NOT USED)
SD2.0 STRUCTURAL DETAILS (NOT USED)
SD3.0 STRUCTURAL DETAILS (NOT USED)
SD4.0 STRUCTURAL DETAILS (NOT USED)

1. ALL CONSTRUCTION SHALL COMPLY WITH, BUT SHALL NOT BE LIMITED TO THE LATEST EDITION AND ORDINANCES OF:

A. CALIFORNIA BUILDING CODE 2022
B. CALIFORNIA RESIDENTIAL CODE 2022
C. CALIFORNIA ELECTRICAL CODE 2022
D. CALIFORNIA MECHANICAL CODE 2022
E. CALIFORNIA PLUMBING CODE 2022
F. CALIFORNIA FIRE CODE 2022
G. CALIFORNIA GREEN BUILDING STANDARDS CODE
H. APPLICABLE SECTIONS OF THE CALIFORNIA ADMINISTRATIVE CODE, TITLE 24 I. 2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS

2. A STAMPED SET OF APPROVED PLANS SHALL BE KEPT AT THE JOB SITE AT ALL TIMES.

3. THE CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO THE START OF CONSTRUCTION.

4. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

PRIOR TO PROCEEDING WITH THE WORK THE CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ERRORS AFTER THE START OF CONSTRUCTION WHICH IS NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT.

5. THE CONTRACTOR IS RESP0NSIBLE FOR PROTECTING ANY ON-SITE UTILITIES FROM DAMAGE DURING THE COURSE OF CONSTRUCTION.

6. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.

7. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY PERMITS AND INSPECTIONS, OTHER THAN PLAN CHECK & BUILDING PERMIT FEES PROVIDED BY THE OWNER.

8. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, EQUIPMENT, TRANSPORTATION AND SERVICES NECESSARY FOR SUCCESSFUL COMPLETION OF THE WORK ALL EQUIPMENT, WORK AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE CODES AND GOVERNING AGENCIES.

9. THE CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT HIMSELF AND HOLD THE ARCHITECT AND OWNER HARMLESS FROM ANY AND ALL CLAIMS FOR DAMAGES FOR PERSONAL, BODILY INJURY, DEATH OR PROPERTY DURING THE COURSE OF THE CONTRACT. FIRE INSURANCE SHALL BE MAINTAINED BY THE OWNER.

10. TEMPORARY POWER AND WATER, WORKERS' TOILET FACILITIES, PARKING AND MATERIAL STORAGE SHALL BE PROVIDED BY THE CONTRACTOR.

11. THE CONTRACTOR SHALL PROTECT ALL FINISHED WORK AND ADJACENT SURFACES FROM DAMAGE DURING THE COURSE OF CONSTRUCTION AND SHALL REPLACE AND/OR REPAIR ANY AND ALL DAMAGE CAUSED BY THE WORKERS.

12. ALL CONSTRUCTION WASTE & DEBRIS MUST BE CONTAINERIZED AT ALL TIMES. UPON COMPLETION OF THE WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN AND ALL DEBRIS SHALL BE REMOVED FROM THE SITE.

13. RECESSED BOXES, EQUIPMENT, CABINETS AND THE LIKE, 8" X 8" OR LARGER, IN "1 - HOUR RATED WALLS", SHALL MAINTAIN A 1-HOUR CONSTRUCTION RATING.

14. DIMENSIONS SHOWN ON FLOOR PLANS, SECTIONS AND DETAILS ARE TO FACE OF STUDS, CENTERLINE OF COLUMN, FACE OF MASONRY, FACE OF CONCRETE UNLESS NOTED OTHERWISE.

15. DOOR LOCATIONS NOT ESTABLISHED BY DIMENSIONS SHALL BE CENTERED IN WALL OR BE LOCATED 4 1 2" FROM ADJACENT WALL TO ALLOW FOR DOOR CASING.

16. ANY DRILLING OR NOTCHING OF STUDS FOR ELECTRICAL WIRING, UTILITY LINES, BRACING ETC. SHALL CONFORM TO LOCAL CODE.

17. ALL GUARDRAILS SHALL BE A MINIMUM OF 42" HIGH. INTERMEDIATE MEMBERS SHALL NOT ALLOW A 4" DIAMETER OBJECT TO PASS THROUGH.

18. PROVIDE A MINIMUM STUD SIZE OF 2 X 6 WHERE USING 2" PLUMBING FIXTURES.

19. PROVIDE FULLY TEMPERED IMPACT GLAZING AT SHOWER/TUB ENCLOSURES AND AT WINDOWS ADJACENT TO BATHTUBS.

20. ALL NEW GLAZING SHALL COMPLY WITH STANDARDS OF THE U.S. CONSUMER PRODUCT SAFETY COMMISSION. MANUFACTURER TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER.

21. ALL TOILETS SHALL BE "ULTRA FLUSH" TYPE AS REQUIRED BY STATE. ALL SHOWER HEADS AND LAVATORY FAUCETS TO BE LOW FLOW.

22. GARAGE DOOR SPRINGS TO BE STATE APPROVED WITH BREAK RETAINERS AND MANUFACTURERS LABELS.

23. ALL INTERIOR FINISH MATERIALS SHALL MEET CLASS III FLAME SPREAD CLASSIFICATION, PER LOCAL CODE.

24. NAILING INSPECTION IS REQUIRED FOR ALL DRYWALL AND LATH AFTER INSTALLATION BEFORE TAPING AND FINISHING. CORNER BEADS TO BE NAILED.

DRYWALL BOARD SPACING TO BE 3/8" MAXIMUM.

25. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES,TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET FROM ANY POWER LINES - WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.

26. EQ EMERGENCY GAS SHUT OFF VALVES TO BE INSTALLED ON ALL GAS FUEL LINES.

27. THE ARCHITECT SHALL BE PROVIDED A KEY OR COMBINATION TO THE LOCK ON JOB SITE GATES FOR ACCESS TO THE CONSTRUCTION SITE AT ALL TIMES.

28. MECHANICAL SUBCONTRACTOR TO PROVIDE THE ARCHITECT WITH A SCHEMATIC LAYOUT FOR ALL MECHANICAL UNITS, DUCT RUNS, AND REGISTER LOCATIONS AND SIZES FOR REVIEW AND APPROVAL PRIOR TO ANY MECHANICAL ROUGH IN.

29. PROVIDE STRUCTURAL OBSERVATION PER CITY OF LOS ANGELES REQUIREMENTS.

30. DRAFT STOPPING (AT 10' INTERVALS HORIZONTAL AND VERTICAL SHALL BE PROVIDED WITHIN A CONCEALED FLOOR/CEILIING ASSEMBLY FORMED OF

COMBUSTIBLE CONSTRUCTION, ATTICS, MANSARDS, OVERHANGS, OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, BETWEEN ATTIC AND CHIMNEY CHASE, AT STAIR STRINGERS, AND SIMILAR CONCEALED SPACES FORMED OF COMBUSTIBLE CONSTRUCTION PER LOCAL CODE.

31. ENCLOSED USEABLE SPACE UNDER INTERIOR STAIRS REQUIRES 1-HOUR FIRE RESISTIVE CONSTRUCTION ON THE ENCLOSED SIDE PER LOCAL CODE.

32. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND; OR OBTAIN A NECESSARY PERMIT FROM STATE OF CALIFORNIA, DIVISION OF OCCUPATIONAL SAFETY & HEALTH (CAL/OSHA, 714-558-4451). THIS PERMIT AND ANY OTHER SAFETY PERMIT SHALL BE OBTAINED PRIOR TO COMMENCE OF ANY WORK.

NORTH
31421 HOLLY DR
LAGUNA BEACH, CA 92651

VICINITY MAP REFERENCE ONLY

MCBEAN RESIDENCE
31421 HOLLY DR,
LAGUNA BEACH, CA 92651

1. THE PERMIT APPLICATION FOR THIS PROJECT IS DEEMED TO HAVE BEEN EXPIRED 180 DAYS AFTER THE DATE FILING .

CONTACT COUNTY BUILDING DEPARTMENT TO OBTAIN WRITTEN 180-DAY EXTENSION(S). [CRC R105.3.2]

2. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND; OR OBTAIN A NECESSARY PERMIT FROM STATE OF CALIFORNIA, DIVISION OF OCCUPATIONAL SAFETY & HEALTH (CAL/OSHA, 714-558-4451). THIS PERMIT AND ANY OTHER SAFETY PERMIT SHALL BE OBTAINED PRIOR TO COMMENCE OF ANY WORK.

3. NEW ONE-FAMILY DWELLINGS SHALL HAVE AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH CRC SECTION R313.3 OR NFPA 13D. SUBMIT 3 SETS OF AUTOMATIC SPRINKLER PLANS TO OFCA FOR APPROVAL (714) 573-6100 [CRC R313]

4. THE SUPPORTING CONSTRUCTION OF FLOOR ASSEMBLIES WITH FIRE RESISTANCE RATED BY SECTION R302.3 SHALL BE OF EQUAL OR GREATER FIRE-RESISTANCE RATING THAN THE FIRE-RATED ASSEMBLY BEING SUPPORTED. [CRC R302.3.1]

5. THROUGH PENETRATIONS OF FIRE-RESISTANCE-RATED CONSTRUCTION SHALL BE IN ACCORDANCE WITH CRC R302.4.1.1 OR R302.4.1.2.

6. MEMBRANE PENETRATIONS OF FIRE-RATED CONSTRUCTION SHALL BE IN ACCORDANCE WITH CRC SECTION R302.4.2.

7. FIREBLOCKING IS REQUIRED IN CONCEALED SPACES 10' O.C. HORIZONTAL, VERTICALLY AT THE CEILING AND FLOOR

LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEY'S AND FIREPLACES. [CRC R302.11]

8. ALL WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8" TO THE EXPOSED GROUND SHALL BE PRESSURE TREATED OR NATURALLY DURABLE TO DECAY. [CRC R317.1, ITEM 1]

9. SILLS AND SLEEPERS IN DIRECT CONTACT WITH CONCRETE OR MASONRY THAT IS IN DIRECT CONTACT WIHT THE GROUND AND GIRDERS WITH LESS THAN 1/2" CLEARANCE TO MASONRY AND CONCRETE SHALL BE PRESSURE TREATED OR NATURALLY DURABLE TO DECAY. [CRC R317.1, ITEM 3&4]

10. FIELD CUTTING ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWAP M4. [CRC R317.1.1]

11. THE MIN. WIDTH OF HALLWAYS SHALL NOT BE LESS THAN 36". [CRC R311.6]

12. AN ELEVATOR PERMIT WILL BE REQUIRED FROM THE ELEVATOR DIVISION OF CAL/OSHA.

13. IT IS THE CONTRACTOR OR OWNER RESPONSABILITY TO PROVIDE ONE HARD SET OF PLANS WITH THE COUNTY APPROVAL STAMP IN THE FIELD FOR THE INSPECTOR TO VIEW.

GENERAL NOTES

1. IN CASE OF EMERGENCY CALL DAVE FRITH, 949-370-3723

2. SEDIMENT FROM AREAS DISTURBED BY CONSTRUCTION SHALL BE RETAINED ON SITE USING STRUCTURAL CONTROLS TO THE MAXIMUM EXTENT PRACTICABLE.

3. STOCKPILES OF SOIL SHALL BE PROPERLY CONTAINED TO MINIMIZE SEDIMENT TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES OR ADJACENT PROPERTIES VIA RUNOFF, VEHICLE TACKING, OR WIND.

4. APPROPRIATE BMP'S FOR CONSTRUCTION-RELATED MATERIALS, WASTES, SPILLS SHALL BE IMPLEMENTED TO

MINIMIZE TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES, OR ADJOINING PROPERTIES BY WIND OR RUNOFF.

5. RUNOFF FROM EQUIPMENT AND VEHICLE WASHING SHALL BE CONTAINED AT CONSTRUCTION SITES UNLESS TREATED TO REDUCE OR REMOVE SEDIMENT AND OTHER POLLUTANTS.

6. ALL CONSTRUCTION CONTRACTOR AND SUBCONTRACTOR PERSONNEL ARE TO BE MADE AWARE OR THE REQUIRED

BEST MANAGEMENT PRACTICES AND GOOD HOUSEKEEPING MEASURES FOR THE PROJECT SITE AND ANY ASSOCIATED CONSTRUCTION STAGING AREAS.

7. AT THE END OF EACH DAY OF CONSTRUCTION ACTIVITY ALL CONSTRUCTION DEBRIS AND WASTE MATERIALS SHALL BE COLLECTED AND PROPERLY DISPOSED IN TRASH OR RECYCLE BINS.

8. CONSTRUCTION SITES SHALL BE MAINTAINED IN SUCH A CONDITION THAT AN ANTICIPATED STORM DOES NOT CARRY WASTES OR POLLUTANTS OFF THE SITE. DISCHARGES OF MATERIAL OTHER THAN STORMWATER ONLY

WHEN NECESSARY FOR PERFORMANCE AND COMPLETION OF CONSTRUCTION PRACTICES AND WHERE THEY DO NOT: CAUSE OR CONTRIBUTE TO A VIOLATION OF ANY WATER QUALITY STANDARD; CAUSE OR THREATEN TO CAUSE POLLUTION, CONTAMINATION, OR NUISANCE; OR CONTAIN A HAZARDOUS SUBSTANCE IN A QUANTITY REPORTABLE UNDER FEDERAL REGULATIONS 40 CFR PARTS 117 AND 302.

9. POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO: SOLID OR LIQUID CHEMICAL SPILLS; WASTES FROM PAINTS, STAINS, SEALANTS, GLUES, LIMES, PESTICIDES, HERBICIDES, WOOD PRESERVATIVES AND SOLVENTS; ASBESTOS FIBERS, PAINT FLAKES OR STUCCO FRAGMENTS; FUELS, OILS, LUBRICANTS, AND HYDRAULIC, RADIATOR OR BATTERY FLUIDS; FERTILIZERS, VEHICLE/EQUIPMENT WASH WATER AND CONCRETE WASH WATER; CONCRETE, DETERGENT OR FLOATABLE WASTES; WASTES FROM ANY ENGINE/EQUIPMENT STEAM CLEANING OR CHEMICAL DEGREASING AND SUPERCHLORINATED POTABLE WATER LINE FLUSHING.

DURING CONSTRUCTION, PERMITTEE SHALL DISPOSE OF SUCH MATERIALS IN A SPECIFIED AND CONTROLLED

TEMPORARY AREA ON-SITE, PHYSICALLY SEPARATED FROM POTENTIAL STORMWATER RUNOFF, WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS.

10. DEWATERING OF CONTAMINATED GROUNDWATER, OR DISCHARGING CONTAMINATED SOILS VIA SURFACE EROSION IS PROHIBITED. DEWATERING OF NON-CONTAMINATED GROUNDWATER REQUIRES A NATIONAL POLLUTANT

DISCHARGE ELIMINATION SYSTEM PERMIT FROM THE RESPECTIVE STATE REGIONAL WATER QUALITY CONTROL BOARD.

NPDES NOTES

EXHIBIT 'B'

CONDITIONS OF APPROVAL
Standard Conditions:

1. The conditions of approval shall be and hereby are obligations of and binding upon the applicant and his/her heirs, successors, assigns, agents and representatives. The conditions shall constitute a covenant running with and binding the land in accordance with the provisions of California Civil Code Section 1468. Failure to comply with such conditions, and each of them, and any other related federal, state and local regulations may be grounds for revocation of the approval, in addition to other remedies that may be available to the City.

2. The applicable Certificate of Use and/or Certificate of Occupancy shall not be issued until City staff has verified compliance with all conditions of approval.

3. Prior to Building Permit issuance, the owner, his architect/designer/structural engineer, and contractor of the subject property shall sign an Affidavit of Plan Consistency, whereby the signees affirm that the structural plans are consistent with the Zoning Division-approved set of plans and any modification will require subsequent review and approval.

4. In the absence of specific provisions or conditions herein to the contrary, the application and all relevant plans and exhibits are incorporated and made a part of this approval. It is required that such plans and exhibits be complied with and implemented in a consistent manner with the approved use and other conditions of approval. Such plans and exhibits for which this approval has been granted shall not be substantially changed or substantially amended except pursuant to a subsequent approval as might otherwise be required or granted pursuant to the terms of Title 25 of the City of Laguna Beach Municipal Code.

5. The permittee shall defend, hold harmless and indemnify, at his/her/its expense, the City, the City Council and other City bodies and members thereof, officials, officers, employees, agents and representatives (collectively, the City) from and against any and all third-party claims, actions or proceedings to attack, set aside, void or annul this approval, or any associated determination made pursuant to the California Environmental Quality Act. This obligation shall encompass all costs and expenses incurred by the City in defending against any claim, action or proceeding, as well as costs, expenses or damages the City may be required by a court to pay as a result of such claim, action or proceeding.

6. Expiration. This approval shall lapse and become void two years following the effective date if the privileges authorized by design review are not executed or utilized or, if construction work is involved, such work is not commenced within such two-year period and diligently pursued to completion. The approval authority may grant a two-year extension of time and, after that initial extension of time, a final one-year extension of time. Such time extensions shall be requested in writing by the applicant or authorized agent prior to the expiration of the beginning two-year approval period or a subsequently approved extension of time.

7. Reapplication Waiting Period. After denial of a project, no application for a project located on the same parcel or building site may be filed or accepted for filing for two months.

8. Light trespass that results in glare is prohibited.

9. Outdoor lighting must be hooded, fully shielded, and aimed downward.

10. Modifications. Additions or enlargements of structures upon property for which a variance has been granted shall not be allowed except pursuant to a subsequent variance as might otherwise be required or granted pursuant to the terms of Title 25 of the City of Laguna Beach Municipal Code.

Project Specific Special Conditions:

1. The five-foot fence proposed along Holly Drive shall be constructed according to the 2022 California Building Code requirements for a non-climbable fence that secures a swimming pool/spa, and include the self-latching requirements for the front access gate.

DRAFT DRB RESOLUTION 22-2245

A RESOLUTION OF THE OF THE DESIGN REVIEW BOARD OF THE CITY OF LAGUNA BEACH, CALIFORNIA APPROVING DESIGN REVIEW 22-2245, AND VARIANCE 22-2266, FOR A 760 SQUARE FOOT ADDITION, A 300 SQUARE FOOT BALCONY, A VARIANCE FOR NOT MEETING THE REQUIRED

PARKING ONSITE AND APPROVING CATEGORICAL EXEMPTION PURSUANT TO CALIFORNIA ENVIRONMENTAL QUALITY ACT.
31421 Holly Drive | APN: 056-061-16
WHEREAS, on January 31, 2023, a notice was mailed to all property owners within a 300' radius and tenants within a 100' radius announcing the February 23, 2023, public hearing of the Design Review Board for the proposed project; and WHEREAS, on February 23, 2023, the Design Review Board carefully considered the oral and documentary evidence and arguments presented at the duly noticed hearing.

NOW, THEREFORE, THE DESIGN REVIEW BOARD OF THE CITY OF LAGUNA BEACH DOES HEREBY FIND, DETERMINE AND RESOLVE AS FOLLOWS:

Section 1: Design Review 22-2245, and Variance 22-2266 for a 760 square foot addition (first level: 351 SF; second level:
409 SF) to an existing 1,875 square foot single-family residence, the removal of an existing chimney, a new 300 square foot second-level rear balcony, new doors/windows, a new bay window, a new above ground spa, a 340 square foot internal remodel that includes the conversion of a bedroom into a new master bathroom, new metal roofing, a new AC unit, replacement of siding, and a variance for the proposed addition without meeting the required parking onsite ("Proposed Project") is approved. The proposed project is exempt from the provisions of the California Environmental Quality Act in accordance with State CEQA Guidelines Section 15301 - Existing Facilities, in that the project consists of the repair, maintenance, or minor alteration of existing structures or topographical features, involving negligible or no expansion of existing or former use.; and
Section 2: The proposed project is consistent with the applicable Laguna Beach Municipal Code Title 25 development standards and guidelines as outlined in the Zoning Review section of the Staff Report.

Section 3: The proposed project is consistent with the Design Review criteria related to access, design articulation, design integrity, environmental context, general plan compliance, landscaping, lighting, neighborhood compatibility, privacy, sustainability, and view equity as outlined in the Design Review section of the Staff Report.

Section 4: The Variance findings can be made for the Proposed Project for the reasons and factual basis set forth in the Variance section of the Staff Report.

Section 5: The project is in conformity with all the applicable provisions of the general plan and any applicable specific plans for the reasons and factual basis set forth in Exhibit A of the Staff Report.

Section 8: Terms and Conditions Run with the Land. These terms and conditions shall be perpetual, and it is the intention of the approval authority and the permittee to bind all future owners and possessors of the subject property to the terms and conditions.

Section 9: Indemnification. The permittee shall defend, hold harmless and indemnify, at his/her/its expense, the City, the City Council and other City bodies and members thereof, officials, officers, employees, agents and representatives (collectively, the City) from and against any and all third-party claims, actions or proceedings to attack, set aside, void or annul the approval of this application for Design ReviewDesign Review, or any associated determination made pursuant to the California Environmental Quality Act. This obligation shall encompass all costs and expenses incurred by the City in defending against any claim, action or proceeding, as well as costs, expenses or damages the City may pay as a result of such claim, action or proceeding. In the event an action or proceeding is filed in court against the City, the Design Review, or any associated determination, the permittee shall promptly be required to execute a formal indemnification agreement with the City, in a form approved by the City Attorney, which shall include, among other things, that the City will be defended by the counsel of its choice, and that the permittee shall deposit with the City sufficient funding, and thereafter replenish the funding, to ensure that the City's defense is fully funded, by the permittee. The deposit amount and replenishment schedule shall be established by the City.

Section 10: Plan Reliance and Modification Restriction. In the absence of specific provisions or conditions herein to the contrary, the attached Staff Report and its Exhibits 'A', and 'B', are incorporated and made a part of this Resolution. It is required that the Exhibits 'B' be complied with and implemented in a manner consistent with the approved use and other conditions of approval. Such exhibits for which this permit has been granted shall not be changed or amended except pursuant to a subsequent amendment to the permit or new permit as might otherwise be required or granted pursuant to the terms of Title 25 of the Laguna Beach Municipal Code.

Section 11: Grounds for Revocation or Modification. Failure to abide by and faithfully comply with Exhibits 'B' and 'C' attached to the granting of the proposed project may constitute grounds for revocation or modification of the permit.

Section 12: Right of Appeal and Effective Date. The applicant or any other owner of property within three hundred feet of the subject property aggrieved by the Design Review Board's decision on Design Review 22-1451 or Variance 22-1928 may appeal such decision to the City Council. The Design Review Board's determination to approve a Categorical Exemption under CEQA may be appealed by any person to the City Council. Any appeal shall be in written form filed with the City Clerk within fourteen calendar days of the decision and shall specifically state each and every ground for the appeal and be accompanied by payment of the required appeal fee. If no appeal is filed timely, the Design Review Board decision will be effective 14 calendar days after the date of the decision.

1. Section 13: For the foregoing reasons and based on the information and findings included in the Staff Report, Minutes and records of proceedings, the Design Review Board of the City of Laguna Beach hereby approves the proposed project, subject to the conditions of approval and plans in the attached Exhibits 'B'.

PASSED on February 23, 2023, by the following vote:
6 6
6 Daniel Latham
Digitally signed by Daniel Latham
DN: C=US,
[email protected],
CN=Daniel Latham
Date: 2025.05.06 16:32:39-07'00'

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022
PERMIT PLAN CHECK 03.23.2023
PERMIT SET 05.08.2023
DELTA 4 08.06.2024
DELTA 5 01.02.2025
DELTA 6 04.29.2025

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
190'
180'
170'
200'
1 2:12
1:12
1:12 126'-2" LOT DEPTH
31421 HOLLY DRIVE
4'-4"
7'-1"
S.Y.S.B.

S.Y.S.B.
7'-1" 5'-1"
7'-4"
4'-9"
20'-0" R.Y.S.B. 7'-1" 26'-11"
TERRACED LANDSCAPE AREA 50'-0" 73'-0"
1 2:12
31441 HOLLY DRIVE
31411 HOLLY DRIVE
℄ HOLLY DRIVE
℄ OCEAN VIEW STREET

EXISTING AREA OF

ROOF TO BE

DEMOLISHED

SHOWN DASHED

EXISTING CHIMNEY

TO BE REMOVED

54.22' 139.52'
60' 113.81' 17'-6"
17'-6"

EXISTING STAIRS

AND GATE TO BE

REPLACED

EXISTING STAIRS

TO BE REPLACED

EXISTING TERRACED

LANDSCAPE WALLS TO BE
CUTBACK FOR NEW STAIR 10'-0" F.Y.S.B. 5'-0" REDUCED GARAGE F.Y.S.B. 10'-0" F.Y.S.B.

EXISTING

STONE PATH

EXISTING

RETAINING WALL
T.O. EXISTING

NON-STRUCTURAL

RETAINING WALL
= 185'-6"

TO BE REMOVED

AND REPLACED
T.O. EXISTING
WALL = 208'-6"
T.O. EXISTING
WALL = 202'-6"
T.O. EXISTING
CURB = 206'-0"
T.O. EXISTING
WALL = 199'-6"
T.O. EXISTING
WALL = 204'-0"
T.O. MAIN LEVEL F.F.
197'-3"
T.O. BASEMENT F.F.
188'-7"
T.O. GARAGE F.F.
206-3"
T.O. EXISTING
WALL = 201'-0" T.O. PATIO F.S.
196'-10"

EXISTING CHIMNEY

TO BE REMOVED
54'-5" LOT WIDTH 139'-0
1 2
"
T.O. EXISTING
WALL = 188'-3"
190'
180'
170'
200'
x x x x x x
1'-0"
13'-2" 19'-5" 10'-0" F.Y.S.B. 73'-0" 50'-0" 26'-11"
4'-9"
7'-4"
5'-1"
S.Y.S.B.

S.Y.S.B.
7'-1"
4'-4"

CANTILEVERED
BAY WINDOW 113.81'
60' 139.52'

54.22'
NEW 5' HIGH WOOD

FENCE AND GATE

NEW AT GRADE
STAIR
NEW 6'-0" HIGH

WOOD FENCE

1. GENERAL CONTRACTOR TO VERIFY AND REVIEW

EXISTING SITE DRAINAGE REQUIREMENTS WITH

ARCHITECT TO DETERMINE IF THE SYSTEM
PROVIDES ADEQUATE SITE DRAINAGE.

2. OBTAIN A SEPARATE PERMIT FOR RETAINING
WALLS, GRADING, AND SHORING (IF REQUIRED).

3. VERIFY EXACT HARDSCAPE AND PLANT MATERIAL

LAYOUTS, MATERIALS AND SPECIFICATIONS WITH
THE ARCHITECT AND LANDSCAPE ARCHITECT.

4. SUBMIT ACTUAL SAMPLES OF ALL FINISH

MATERIALS TO THE OWNER AND ARCHITECT FOR

REVIEW AND APPROVAL PRIOR TO PURCHASE AND
INSTALLATION.

5. FIELD VERIFY WITH ARCHITECT ALL SITE POWER
AND FINISHED SITE LIGHTING LOCATIONS.

GENERAL NOTES
℄ OCEAN VIEW STREET
31411 HOLLY DRIVE
31441 HOLLY DRIVE
℄ HOLLY DRIVE 3:12 3:12

TERRACED LANDSCAPE AREA
31421 HOLLY DRIVE
1:12
1:12
1 2:12

BUILDING SETBACK

SITE WALL
FENCE

PROPERTY LINE

SITE PLAN LEGEND
20'-0" R.Y.S.B. 7'-1" 17'-6"
17'-6"
TRASH
STORAGE 5'-6"

AC UNIT NOISE ANALYSIS
SOUND RATING OF EQUIPMENT 76 dB
+ EQUIPMENT LOCATION FACTOR <3 dB>
- BARRIER SHIELDING FACTOR <--->
- DISTANCE FACTOR <23.5>
- SOUND ATTENUATION REDUCTION <6dB>
TOTAL 76-26.5 = 49.5 dB (COMPLIES WITH CITY OF LB REQ.) 5'-0" REDUCED GARAGE F.Y.S.B.

REFERENCE SHEET A501
DETAIL #3 FOR SOUND

ATTENUATION TECHNIQUES
REFERENCE SHEET A501
DETAIL #4 FOR

MANUFACTURER'S

SPECIFICATION SHEET
7'-3"
PARKING SPACE #1
8'-8"x18'-0"

EXISTING

STONE PATH

EXISTING

RETAINING WALL
T.O. EXISTING WALL
BELOW = 188'-3"
T.O. NEW WALL =
185'-6" TO REPLACE
(E) NON-STRUCTURAL
WALL

NEW AT GRADE
STAIR
NEW 4' HIGH WOOD

FENCE AND GATE
T.O. MAIN LEVEL F.F.
197'-3"
T.O. BASEMENT F.F.
188'-7"
T.O. GARAGE F.F.
206-3"
T.O. EXISTING
WALL = 208'-6"
T.O. EXISTING
CURB = 206'-0"
4'-0"
T.O. PATIO F.S.
196'-10"
PROVIDE 5' HIGH WOOD POOL SECURITY
FENCING PER LBMC 25.50.016 AND LBMC

25.50.012 (A). THE FENCE SHALL HAVE

SELF-CLOSING GATES AT LEAST FIVE FEET
HIGH WITH SELF-LATCHING MECHANISM.

LATCHES SHALL BE INSTALLED AT LEAST
FOUR FEET ABOVE GROUND LEVEL.

NEW 6'Ø PRE-FABRICATED,

FREESTANDING, SELF CONTAINED
JACUZZI. JACUZZI TO BE COVERED

WITH LOCKABLE COVER WHEN NOT
IN USE. AN AUTOMATIC FILL DEVICE
IS NOT TO BE USED.
17" HIGH STEP / SEAT
AROUND 6' Ø JACUZZI
5'-0"
54'-5" LOT WIDTH 139'-0
1 2
"
F.G. = 185-9"
DN
(N) 6'-0" RETAINING WALL
DETAIL 6/S-0.20
(N) V-DITCH FOR

DRAINAGE

EXISTING APPROVED
28" DECK EXPANSION
4T @ 12"
5R @ 6" 10'-0"
7'-1" S.Y.S.B. 126'-2" LOT DEPTH

SITE PLANS
A006
1 1/8" = 1'-0"

EXISTING SITE PLAN
NORTH
2 1/8" = 1'-0"

PROPOSED SITE PLAN
NORTH
6 5
6 DOOR & FRAME REFERENCE,

REFER TO DOOR & FRAME
SCHEDULE ON A900

NEW DOOR

EXISTING WALL &

DOOR TO REMAIN

NEW PARTITION WALL

FLOOR PLAN LEGEND

ROOM NUMBER

ROOM NAME ROOM
NAME
100

ELEVATION REFERENCE

SHEET NUMBER

VIEW NUMBER

KEYNOTES
MECHANICAL / PLUMBING (INSTALL PER MFR. REQUIREMENTS)
P1 WATER CLOSET - MAXIMUM 1.28 GALLON PER FLUSH. CONFIRM WITH OWNER AND ARCHITECT FOR FLOOR MOUNT OR WALL MOUNT SPEC.

P2
SINK & FAUCET - VERIFY MFR. & MODEL WITH OWNER & ARCHITECT.

CONFIRM MOUNTING STYLE WITH OWNER AND ARCHITECT. PROVIDE GARBAGE DISPOSAL WHERE REQUIRED. INSTALL PER MFR. SPEC'S P3
SHOWER VALVE - VERIFY HEAD QUANTITY, LOCATION, MFR. & MODEL WITH OWNER AND ARCHITECT. INSTALL PER MFR'S SPECIFICATIONS.

CONTROL VALVE FOR SHOWER SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE (418 CPC)

SHOWER DRAIN TO BE INFINITY LINEAR DRAIN
P4
SOAKING TUB & VALVE, VERIFY MFR. & MODEL WITH OWNER. INSTALL PER MFR'S SPEC'S. CONTROL VALVE FOR BATHTUB SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE (418 CPC)
P5 HOSE BIB - MOUNT IN RECESSED CABINET, CONFIRM LOCATIONS WITH

OWNER AND ARCHITECT
P6 OUTDOOR SHOWER
P7 POT FAUCET
P8

WATER HEATER - AMERICAN WATER HEATERS RESIDENTIAL GAS
HIGH-EFFICANCY POWER DIRECT VENT 75 GAL., MODEL VG6275T100NV, PER T-24. PROVIDE RECIRCULATING PUMP. WATER HEATER MUST BE STRAPPED TO WALL. PROVIDE AIR FOR COMBUSTION & VENTILATION PER CMC 701, INSTALL PER MFR'S SPEC'S. SEE A151 LOWER LEVEL POWER PLAN FOR MORE INFORMATION. PROVIDE 3 INCH CLEARANCE ON ALL SIDES, BACK AND TOP AND 6 INCHES IN FRONT. ALL WATER HEATER

INSTALLATION LOCATIONS, REGARDLESS OF PROPOSED WATER HEATING SYSTEM, SHALL HAVE: (BEES 150.0(n)1A-D)
P9
AC PRO ALLIED #4AC16L36P-50A 14 SEER CONDENSING UNIT. AC UNIT TO MAINTAIN A 5-FOOT CLEARANCE FROM ALL PROPERTY LINES. MAXIMUM DECIBEL LEVEL TO BE 60 DB DURING THE DAY AND 50 DB AT NIGHT.

PROVIDE SOUND ATTENUATION AND SHOCK ABSORBENT BASE AS
REQUIRED., INSTALL PER MFR'S SPEC'S. (13.00 SEER/10.00 EER, MIN.) P10

CARRIER INDOOR DUCTED HEATING & COOLING MULTI-ZONE AIR HANDLER UNIT, (95% AFUE, MIN.) PER T-24, PROVIDE AIR FOR COMBUSTION & VENTILATION PER CMC 701, INSTALL PER MFR'S SPECS. PROVIDE 3" CLEARANCE ON ALL SIDES, BACK AND TOP AND 6" IN FRONT. ANCHOR FAU PER CMC 303.4 AND MFR'S INSTRUCTIONS
P11

HIGH EFFICIENCY TANKLESS WATER HEATER - WATER HEATER TO BE WALL MOUNTED. PROVIDE AIR FOR COMBUSTION & VENTILATION PER CMC 701, INSTALL PER MFR'S SPEC'S.

CABINETS
C1 CLOSET MILLWORK - VERIFY LAYOUT, STYLE & FINISH WITH OWNER AND ARCHITECT.

C2

FLOOR & WALL MOUNTED CABINETS & MILLWORK, VERIFY LAYOUT, STYLE & FINISH WITH OWNER AND ARCHITECT. AT BASE CABINETS PROVIDE

STONE SLAB COUNTERTOP & BACK SPLASH, VERIFY SPECIFICATION WITH

OWNER & ARCHITECT

APPLIANCES (INSTALL PER MANUFACTURER REQUIREMENTS)
A1 WASHER - PROVIDE RECESSED PAN & FLOOR DRAIN
A2
DRYER - 4" MIN. VENT TO OUTSIDE, EQUIPPED WITH A BACK-DRAFT DAMPER. MAX DUCT LENGTH 14' WITH (2) 90° BENDS FOR MTL. DUCT, INSTALL PER CMC 504.3.1.2 & MFR'S SPEC'S.

A3 DISHWASHER - INSTALL PER MFR'S SPEC'S
A4 SUB-ZERO REFRIGERATOR/FREEZER
A5

RANGE & HOOD - WOLF DUAL FUEL RANGE & WOLF PRO WALL DUCTED EXHAUST HOOD. MINIMUM 100 CFM PER CMC 504.2 & ASHRA 62.2. MAX.

SOUND RATING OF 2 SONE @ 100 CFM. INSTALL PER MFR'S SPEC'S.

PROVIDE SMOOTH METAL SURFACE ON INTERIOR OF DUCTED EXHAUST HOOD.

A6 WOLF MICROWAVE OVEN DRAWER
A7 WOLF 30" BUILT-IN OVEN
A8 UNDERCOUNTER SUBZERO REFRIGERATOR

FINISHES
F1 TILE SHOWER WALLS & FLOOR - VERIFY SIZE, PATTERN & STYLE WITH

OWNER AND ARCHITECT, INSTALL PER MANUFACTURER'S SPECIFICATION F2

STONE TILE FLOOR - VERIFY SIZE, PATTERN & STYLE WITH OWNER AND

ARCHITECT, INSTALL PER MANUFACTURER'S SPECIFICATION
F3 WOOD FLOORING - CONFIRM SPECIFICATION WITH OWNER AND

ARCHITECT
F4 NOT USED

MISCELLANEOUS
M1 FRAMELESS GLASS - PROVIDE SAFETY GLASS
M2 DRYER COMPARTMENT MAKEUP AIR VENT, 100 SQ. IN. PER CMC 504.3.1 M3 CABLE HANDRAIL/GUARDRAIL - 42" HIGH, CONFIRM FINISH AND STYLE

WITH OWNER AND ARCHITECT
M4 NOT USED
M5

GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND IT'S ATTIC, STRUCTURE(S) SUPPORTING FLOOR/CEILING ASSEMBLIES BY 5
8" GYPSUM
BOARD APPLIED TO THE GARAGE SIDE, PER CRC R302.6.

M6 PROVIDE SCHLUTER-DITRA-HEAT ELECTRIC FLOOR WARMING SYSTEM AT THE ENTIRE BATHROOM AREA, INSTALL PER MFR'S SPEC'S.

M7

AT ENCLOSED ACCESSIBLE SPACES UNDER STAIRS THE WALLS,

UNDER-STAIR SURFACE & SOFFITS SHALL BE PROTECTED ON THE ENCLOSED SIDE BY 5
8" GYPSUM BOARD.
001
XXXX
X

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022
PERMIT PLAN CHECK 03.23.2023
PERMIT SET 05.08.2023
DELTA 4 08.06.2024
DELTA 5 01.02.2025
DELTA 6 04.29.2025

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
190' ENTRY BENCH
BAR
5'-5" X 2'-0"

LINE OF EXISTING

GARAGE ABOVE

EXISTING

RIDGE ABOVE

EXISTING

BEAM ABOVE

ROOF ABOVE
PLANTER 5'-7" 9'-8" 4'-5
1 2
" 5'-9
1 2
"
4'-5
1 2
"
4'-5"
MASTER
CLOSET
110
POWDER
103
ENTRY
101
MASTER

BATHROOM
109
MASTER

BEDROOM
108
LIVING
ROOM
104
DINING
ROOM
105

KITCHEN
106
PANTRY
107
DECK

BUILT-IN

WINDOW SEAT
11 1
2 " 2'-3"
8'-6" 2'-6"

CANTILEVERED

BAY WINDOW

CANTILEVERED
BAY WINDOW 13'-3"
28'-6" 10'-0"
T.O. MAIN LEVEL F.F.
197'-3"
T.O. DECK F.S.
197'-1"
A500
2 A501
2 A502
2 A503
2 A600
1 BUILT-IN
DESK
UP UP
A600
2 T.O. PATIO F.S.
196'-10"
T.O. LANDING
198'-1"
T.O. LANDING
200'-7"
T.O. LANDING
203'-1"
T.O. LANDING
206'-3"

LANDING AT EXISTING GRADE
4'-0"
⅊
4'-4" S.Y.S.B.
7'-1" S.Y.S.B. 10'-0" F.Y.S.B
⅊
NEW 6'Ø PRE-FABRICATED,

FREESTANDING, SELF
CONTAINED JACUZZI. BUILT-IN

SEATING
17" HIGH STEP /
SEAT AROUND 6' Ø

JACUZZI
5'-0" A601
#
BENCH
103
110
A
110
B
109
A
108
A
108
D
108
E
108
F
108
G
105 104
A
105
B
106
F
106
E
106
D
106
C
106
B
106
A
107
101
A
108
C
108
B
101
C
DN
P1
P1
C2
C2
P2
C2
P2
C2
C2
C2
C2
C2 C2
C2
P2
C2
C2
C2
C2
C2
C1
P3 F1
P4
P5
P7
A3
A5
A6
A7
A4
A8
F2
F2
F3
F3
M1
M3
M3
M6
109
C
109
D
109
E
109
F

REFERENCE STAIR

DETAILS PLAN ON
1/A700 1'-6"
1'-6"
6'-11
1 2 5'-0 " 1
2 " 16'-6" 3'-7"
5'-8
1 2
" 9'-10
1 2
" 12'-5"
110
B 3'-4
1 2
" 6'-4
1 2
"
2'-7
1 2 2'-5 " 1
2 " EQ. EQ.
2'-3"
4'-11
1 2
"
2'-6
1 2
"
110
B
109
G
3'-6
1 2
" 1'-6" 3'-5
1 2 1'-6 " 12
"
110
B EQ. EQ.
4'-3
1 2
" EQ. EQ.

EQ. EQ.
4'-0" 6'-1" 4'-8"

FUR WALL TO FLUSH WITH
SLIDING DOOR FRAME 3'-0"
28" DECK EXPANSION

EXISTING APPROVED

MAIN LEVEL NEW

WORK PLAN
A101
1 1/4" = 1'-0"

MAIN LEVEL NEW WORK PLAN
NORTH
6 6

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022
PERMIT PLAN CHECK 03.23.2023
PERMIT SET 05.08.2023
DELTA 4 08.06.2024
DELTA 5 01.02.2025
DELTA 6 04.29.2025

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110 9'-0"
T.O. GARAGE F.F.
206-3" 8'-8"
T.O. BASEMENT F.F.
188'-7"
T.O. MAIN LEVEL F.F.
197'-3" ⅊
10'-0"
F.Y.S.B.
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB
5'-0"

REDUCED
GARAGE F.Y.S.B.EXISTING HEIGHT ABOVE CURB 9'-8"
T.O. UPPER CURB
206'-0"
40'-0" 13'-0"
30' BUILDING

ENVELOPE ABOVE
EXISTING GRADE 2 5 3 3 4 4 1 4

EXISTING GRADE

EXISTING RETAINING
WALLS
FLOOR LINE BEYOND HEIGHT ABOVE GRADE EXISTING HEIGHT ABOVE GRADE 18'-2" 20'-2" EXISTING HEIGHT ABOVE CURB 9'-8" T.O. RAILING
3'-6" A.F.S. 9'-0"
T.O. GARAGE F.F.
206-3" 8'-8"
T.O. BASEMENT F.F.
188'-7"
T.O. MAIN LEVEL F.F.
197'-3"
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB ⅊
10'-0"
5'-0"

REDUCED
GARAGE F.Y.S.B.

T.O. UPPER CURB
206'-0" 13'-0"
F.Y.S.B.

T.O. ROOF
210'-6"
40'-0" 30'-0"
30' BUILDING

ENVELOPE ABOVE
EXISTING GRADE 6 7 9

EXISTING GRADE

STAIR LANDING AT

EXISTING GRADE

EXISTING RETAINING
WALLS
NEW 6'Ø PRE-FABRICATED,

FREESTANDING, SELF
CONTAINED JACUZZI.

REMOVE EXISTING

RETAINING WALLS

FLOOR LINE BEYOND
17" HIGH STEP / SEAT
AROUND 6' Ø JACUZZI
(N) 6'-0" RETAINING WALL
PER DETAIL 6/S-0.20
(N) V-DITCH FOR

DRAINAGE
10'-0" 28" DECK EXPANSION

EXISTING APPROVED

ELEVATION KEYNOTES
EXISTING ROOFING TO BE REPLACED WITH CLASS 'A' STANDING SEAM METAL ROOF.

PROVIDE GUTTERS AND DOWNSPOUTS TIED INTO EXISTING DRAINAGE SYSTEM

EXISTING ROOF TO BE REPLACED WITH NEW ENTRY ROOF

EXISTING STAIR TO BE REPLACED, REFERENCE NEW WORK PLANS

EXISTING WINDOWS / DOOR TO BE REMOVED, REFERENCE NEW WORK PLANS FOR

REVISED OPENING

EXISTING CHIMNEY TO BE REMOVED

CUT OPENING FOR NEW DOOR OR WINDOW, REFERENCE NEW WORK PLANS

NEW RAISED ROOF AT ENTRY, REFERENCE NEW WORK PLANS

PROPOSED EXTERIOR LIGHT FIXTURE, REFERENCE EXTERIOR LIGHTING PLAN FOR MORE INFORMATION. LIGHT FIXTURES MUST BE DOWN LIT OR SHIELDED TO PREVENT GLARE. TOP OF FIXTURE TO BE OPAQUE.

NEW HORIZONTAL SIDING, REFERENCE DETAILS 3-5/A800

NEW BAY WINDOW
NEW SELF CLOSING WOOD GATE WITH SELF-LATCHING MECHANISM. REFER TO SITE PLAN FOR HEIGHT 123456789
10 11

EXTERIOR

ELEVATIONS
A502 2 1/4" = 1'-0"
PROPOSED WEST ELEVATION 1 1/4" = 1'-0"
EXISTING WEST ELEVATION 6 6
1 From: L Austin
Sent: Tuesday, June 3, 2025 2:01 PM
To: Latham, Daniel CD <[email protected]>
Subject: Fwd: Design Review 25-0891 31421 Holly Drive
[NOTICE: This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] Dear Mr. Daniel Latham,
I have forwarded you the e mail we discussed. Please let me know if you have any problems opening any of the information and that you are able to expand the pictures for review. From the pictures of the before and actual, you will see the actual built deck is far beyond the on 28 inches (2 feet 4 inches) that is referenced on the Notice of Public Hearing. Aside from that, there are privacy concerns, cantilevered concerns, social gatherings impact on our living areas, and our view being compromised. The purpose of the original comprehensive design review is to address these types of issues and concerns prior to any construction and as one whole project.

Thank you,
Lori Austin
Begin forwarded message:

From: L Austin
Subject: Design Review 25-0891 31421 Holly Drive
Date: June 3, 2025 at 12:44:32 PM PDT
Attachment 4
56 2
To:

Dear Mr. Daniel Latham, Associate Planner,
As requested, we are submitting comments to the upcoming Design Review mentioned above. I am hopeful I can provide the information within one e mail. I will follow up with you after the documentation is sent. I have outlined in pictorial format some of our concerns. Please let me know if I have failed to meet the requirements for comments, or if I have been unclear with the information provided.

Thank You for your time in this matter.

Lori Austin
Original staking 2-23-2023 looking down from our deck
57 3
Original staking 2-23-2023 from our deck .

Construction Prep for deck
58 4
Construction prep for deck continues
59 5
Actual deck with
new staking of the proposed 28 inches (2 feet, 4 inches) of deck extension. This newest staking does not accurately reflect the original staking of 2-23-2023. 60 6
Picture from our master bedroom. Our master bedroom is directly below our deck. 61 7
View obstruction from our main living space. The open window depicts the placement of the original staked flags of
2-23-2023
62 From: L Austin
Sent: Tuesday, June 3, 2025 4:28 PM
To: Latham, Daniel CD <dlatham@lagunabeachcity net>; L Austin ; Michael Austin Subject: DR 25-0891 2-23-2023 original staking from our main living space 63 [NOTICE This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe ] 64 From: L Austin
Sent: Tuesday, June 3, 2025 4:21 PM
To: Latham, Daniel CD <dlatham@lagunabeachcity net>; L Austin Michael Austin Subject: DR 25-0891 picture from our master bedroom Our bedroom is directly below our deck anyone on the deck can see into our bedroom 65 [NOTICE This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe ] 66 From: L Austin
Sent: Tuesday, June 3, 2025 4:14 PM
To: Latham, Daniel CD <dlatham@lagunabeachcity net>; L Austin ; Michael Austin Subject: DR 25-0891 New staking of deck showing its overhang cantilever of deck 67 [NOTICE This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe ] 68 From: L Austin
Sent: Tuesday, June 3, 2025 4:04 PM
To: Latham, Daniel CD <[email protected]>; L Austin Michael Austin Subject: DR 25-0891 construction prep for deck continues 69 [NOTICE: This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] 70 From: L Austin
Sent: Tuesday, June 3, 2025 3:52 PM
To: Latham, Daniel CD <dlatham@lagunabeachcity net>; L Austin ; Michael Austin Subject: DR 25-0891 Original staking 2-23-2023 from our deck 71 [NOTICE This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe ] 72 From: L Austin
Sent: Tuesday, June 3, 2025 3:45 PM
To: Latham, Daniel CD <dlatham@lagunabeachcity net>; L Austin ; Michael Austin Subject: Original staking 2-23-2023 looking down from our deck 73 [NOTICE This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe ] 74 1
Nasman, Jordan CD

From: L Austin
Sent: Tuesday, June 3, 2025 4:31 PM
To: Latham, Daniel CD <[email protected]>; L Austin ; Michael Austin Subject: DR 25-0891 view obstruction from our main living space. The open window depicts the placement of the 2-23- 2023 original stakes
75 2
76 3
[NOTICE: This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe.]
77 1
Nasman, Jordan CD

From: L Austin
Sent: Tuesday, June 3, 2025 4:08 PM
To: Latham, Daniel CD <[email protected]>; L Austin ; Michael Austin Subject: DR 25-0891 New staking of proposed 28 inches (2 feet, 4 inches) of deck extension. Not accurate to original staking 2-23-2023
78 2
79 3
[NOTICE: This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe.]
80 1
Nasman, Jordan CD

From: L Austin <[email protected]>
Sent: Tuesday, June 3, 2025 4:01 PM
To: Latham, Daniel CD <[email protected]>; L Austin ; Michael Austin Subject: DR 25-0891 2-23-2023 lower section of original staking poles 81 2
82 3
[NOTICE: This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe.]
83 1
Nasman, Jordan CD

From: L Austin
Sent: Tuesday, June 3, 2025 3:58 PM
To: Latham, Daniel CD <[email protected]>; L Austin ; Michael Austin Subject: DR-25-0891 construction prep for deck
84 2
85 3
[NOTICE: This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe.]
86 This transcript was exported on Aug 14, 2025 - view latest version here.

Clipped video_31421 Holly Drive (Completed 08/14/25)
Transcript by Rev.com

Page 1 of 9 ends

CDD Designee:
31421 Holly Drive. Does the staff planner have any comments? Daniel Latham:

Sure. Similar to the previous project, there were comments regarding the deck extension. It's a 28-inch elevated deck extension, which totals 67 square feet of additional deck. There was a prior approval to implement the deck and there is one neighbor with concerns about the project, the adjacent neighbor.

CDD Designee:

Okay. I will now open the item for public hearing. Does the project applicant have any comments? Dave Frith:

I do. Good afternoon. It's Steve Frith, project architect here on behalf of my friends Ina and Gordon McBean, who after two years are getting close to wrapping their house construction up, which I think will be welcome news for the neighborhood.

I don't know if you have access to the letter that was submitted by the one neighbor that had expressed some concern. Do you guys have that?
CDD Designee:

Yes.

Dave Frith:

Okay.

CDD Designee:

Staff has received that comment letter and I believe it's been posted to the website as well, yes.

Dave Frith:

Okay, great. So I just basically I printed a picture of that. I can't tell if there is a question over the staking approval. So, why don't I start with that and then finish with the fact that in my personal opinion, 24 inches, two-foot-four inches should be administratively approved. There's no impact on anybody.

The neighbors may disagree, but there were no comments about the size of the deck specifically with the original DRV approval. But why don't I start with basically a copy of the certified staking plan? The confusion and the reason that we're here today, if you look at the picture that they submitted, is there was a two-foot-four inch deck here off of the McBeans' home. This is taken from the neighbors that I think had some concerns.

And the mistake that the general contractor made is our deck approval is 10 feet, and he went ahead and framed it 10 feet from the existing deck that's basically two feet off of the face of the house. So, just from a matter of explanation, we certainly weren't thumbing our nose at the process. This is an honest mistake that was made by a contractor that I think is doing a great job.

He misunderstood that the 10-foot deck extension per my plan, which is my responsibility as the architect, was to be taken from the home but not from the deck that was removed. So, that's point one, Attachment 5
87 This transcript was exported on Aug 14, 2025 - view latest version here.

Clipped video_31421 Holly Drive (Completed 08/14/25)
Transcript by Rev.com

Page 2 of 9 ends

why we're here. Point two, there's a radius retaining wall that clearly shows from the neighbor's view where the stakes are and the stake comes down behind the radius retaining wall.

I went ahead and brought a copy of the certified staking plan. That shows exactly where that stake is, 10 feet off of the face of the house, and the curved retaining wall. And so if you look here, this is just a copy of the certified staking plan. This is a copy of the stake and the curved wall.

And so, from that point, we... This is another drawing that shows the curved retaining wall. The deck was supposed to come here on this row of columns, and you can kind of see in the plan that basically that row of columns is in line with the adjacent neighbor to the south that I think is expressing some concerns. And so, what we did is we went ahead and restaked it another two-foot-four inches out per our proposed plan.

It's actually constructed right now, and I hadn't heard that there were any concerns until we sent out the notification. It's actually been constructed that way for many, many months. But I went ahead and basically was on site today with a tape measure. I know that you can't see this, but if anybody would like this for the record, it shows that the deck is 12 feet deep from the face of the house.

So it's actually four inches less than what we're proposing. And I don't know if there's any benefit for the record to ask for a two-foot deck extension instead of our original two-foot-four proposal. But essentially we're here that asking for administrative review, administrative design review board approval for a deck that was inadvertently built two feet farther than the approved plan.

Last, I don't know if I'm running short on time, but I'm almost done. Last comment is just this is where the column is and then where the deck, you can see basically from the neighbor standpoint, the as-built deck condition that we're asking for approval. And then lastly, just two pictures of the neighborhood.

This is my client's house, the McBeans, this is the house directly to the north.

All of the views here are spectacular, but essentially the primary view is directly towards the ocean. This is the house directly to the north. This is the as-staked, as-built deck that's two feet larger than the approved plan that clearly has no impact here. And a picture of the homeowners to the south that are concerned, this is their deck and their home.

This is the as-built. The deck is actually located to the north of the property, opposite, and that was actually by design so that it would have minimal impact on the neighbors to the south. So, again, hopefully that clarifies the fact that I have documentation that it was staked appropriately. It's been built for many, many months without concern or any concern that I was aware of, and we're actually asking for a two-foot extension to match what's in the field.

Hopefully this isn't a matter that needs to go to design review board. As I said, I don't think there's any noticeable impact or detriment to the neighborhood and hopefully you agree. Thank you.

CDD Designee:

Thank you for providing that project background and history.

Dave Frith:

You're welcome.

CDD Designee:

If there are any members of the public that'd like to address this item, please come to the podium and state your name.
88 This transcript was exported on Aug 14, 2025 - view latest version here.

Clipped video_31421 Holly Drive (Completed 08/14/25)
Transcript by Rev.com

Page 3 of 9 ends

Mike Austin:

Hello. Hi, my name is Mike, Mike Austin. I'm the neighbor to the south that the architect is referring to.

The staking plan did follow the original plan. It was staked according to the design review plan, and that's what we were expecting.

So there was an overhang and the staking plan for design review calls for 10 feet at the face of the house, but on the bottom it's very clear in the design review, they take that staking measurement out and then go up and it results in about an eight-foot deck.

And that's just how it was designed that that's in the original design review. That measurement on the staking plan is crystal clear. So, what has happened is that the deck was builtLori Austin:
[inaudible 00:07:46]-
Mike Austin:

Oh, I don't know if he wants to seeLori Austin:
... for the house.

Mike Austin:
... the... It's not a deck, it's just some two-by-four shading.

Lori Austin:

There's noDave Frith:

Make sure to talk upLori Austin:

Yes, I'll wait track [inaudible 00:08:04].

Dave Frith:

And you're in session.

Mike Austin:

So, thereDave Frith:

Mike, this is a larger one. I don't know if you want to share that, but it's the same pictureLori Austin:

Oh, we have that89
This transcript was exported on Aug 14, 2025 - view latest version here.

Clipped video_31421 Holly Drive (Completed 08/14/25)
Transcript by Rev.com

Page 4 of 9 ends

Mike Austin:

Yeah.

Lori Austin:
... we can do that.

Mike Austin:

SoDave Frith:

It's just a larger print.

Mike Austin:
... so the original, that shows the original staking plan, so the request is not for two feet, 24 inches. It was already built two feet beyond the staking, and now they're going another two feet beyond that to result in roughly a 12-foot deck. So we do have concerns about the overall process not following the staking plan, not considering the neighbor's privacy impact, or view, or congregation of living space nearby our living space.

Overall, it's just a little frustrating that it was built. I did try to come in a couple of times, but the plans were not available to double-check some things. But now we've got a deck that has been constructed at roughly two feet outside the staking, and now they're asking for another two feet. So, I just think that this should go back to design review.

One thing I would mention about design review is that it's comprehensive. So you kind of look at all the pieces at once and this plan was 700 square feet of addition and a deck, and you kind of look at it all, and you're there at the forum and you make your comments based on what's presented on the staking plan and the overall plan and the design review.

And if it varies, I just think it's impactful because just one component, "Oh, well we'll fix that." It's just we looked at this whole thing as neighbors in the design review process and now it's come down to, "Oh, oops, we made a mistake, and we constructed 10 feet instead of the staking," and, "Oops, we made another mistake and now we're 24 inches plus four, 28 inches beyond that." It does start to get impactful. So, that's all I wanted to say on that. Just overall view, privacy, congregation, building a deck out on over a slope, which is discouraged on the design process. So, that's all I have to say.

CDD Designee:

Thank you for your comment. If anyone else would like to, please state your name for the record? Lori Austin:

Yes, hi, I'm Lori Austin, and aside from the things that he's already discussed, I do want to point out that when you look at... Can I bring this to you?
CDD Designee:

Sure.
90 This transcript was exported on Aug 14, 2025 - view latest version here.

Clipped video_31421 Holly Drive (Completed 08/14/25)
Transcript by Rev.com

Page 5 of 9 ends

Lori Austin:

You need toCDD Designee:

Have youLori Austin:
... have the other one.

CDD Designee:
... previously provided these exhibits to the staff planner? Lori Austin:

Yeah, so I can justCDD Designee:

Are they the record?
Lori Austin:
... show it, I can show it to you, but when youCDD Designee:

Sure.

Lori Austin:
... do the initial flag staking, you assume that that is going to be the deck, which is what we made the assumption on. So and then the original design review, we were fine with that. That was a reasonable deck, in that space. And I know that they built it on that side to be more cognizant of our side, because we sit on our deck a lot.

And the other deck on the other side extended much farther out, so they weren't impacted because that extended much farther out. However, when they built it, and I will show you on these photos here, they are much farther out than it was originally proposed and approved at that time. We did not have any comments about that because we felt it was, at the size it was at that time reasonable.

So, I will show you this. He has that larger photo that you can show if you'd like, but besides the flagging one that he had, here's this from our deck. So first I took a picture from the top.

Speaker 6:

Make sure this is a picture of MikeLori Austin:

I'm sorrySpeaker 6:
91 This transcript was exported on Aug 14, 2025 - view latest version here.

Clipped video_31421 Holly Drive (Completed 08/14/25)
Transcript by Rev.com

Page 6 of 9 ends

... [inaudible 00:11:47]-
Lori Austin:

Oh, okay. So I can show you this from here? Okay, so the original, I don't know where it went, but I took a picture from up top, and here's a picture directly from our deck, and you can clearly see the house right here, right?
The stucco house right here. The deck does not extend past that stucco house and it goes over and it goes in. Right? And so I thought, "Okay, well that's good. It wouldn't have affected the neighbors on the other side because what you don't see, but I'll show you, is they have a top deck and a lower deck, but this deck is tucked in, not affecting the neighbor on the other side." And to me it's like, "Okay, it's tucked in enough, it's not going to be protruding past my house. We can kind of be like neighborly this way or what have you, but not have you right there." Also, at that space that it is, it isn't overshadowing by another four feet. And this whole space right here, right below that is my master bedroom and my windows and everything because my deck is not cantilevered.

So, my bedroom downstairs, it encompasses not only the family room or our main living space, but also this deck. So now they can see right into my bedroom. Plus, we have a bedroom that's on a raised foundation. Okay? So, you would think that, "Okay, but it's so far down you won't notice it." However, my floor is raised up. So, when I'm standing in my bedroom in that space, my master bedroom, the height, I feel like the height up top of my head is equal to the deck height. But that's for me looking from afar. I don't actually know that to be the case, but we are on a raised foundation, so, and our windows are such that when I'm standing in my bedroom, the bottom of my window goes to about right here, and then it goes up to about right here.

So, that's our window. And when I'm standing there, they're right there. I can show you as well, if you look at this house as the guideline for where that deck should be, then you go to the footings that they have. Here's the end process of the amount of dirt moving for that deck. And as he described this deck right here, that's not a deck.

There's no physical access to that little structure. There's nothing, you don't sit on that. You don't go on that. There's fixed windows over there, and these are kitchen windows over here. So it wasn't ever a deck. And then this is the footings that they prepared for that new deck. And here is the house right here that ends those flags.

So you can see that just by that, the footings are way past that house and then the deck cantilevers over these footings. Okay? So, this is not just a 28-inch deck extension off of the original design. When you look here, now, from our deck and you saw it beforeCDD Designee:

There is aLori Austin:
... from our deckCDD Designee:
... three-minute time limit, soLori Austin:
92 This transcript was exported on Aug 14, 2025 - view latest version here.

Clipped video_31421 Holly Drive (Completed 08/14/25)
Transcript by Rev.com

Page 7 of 9 ends

Okay.

CDD Designee:
... you'll need to wrap up soon.

Lori Austin:

Okay. So I'll do just a couple more. So, here's our deck and I was asked to do a similar photo, and you have them. So I tried to include the same door, the same everything, the same presentation. You can see that stucco gray house where the deck should have ended, and you can see how far it extends past that stucco gray house. So it's not two feet, four inches.

Here is another view where I am trying to be on a par with our railing to the overhang, and the cantilevering of their deck, the new deck, when it should not have been built past this gray area. So, it's much more than described as this two foot, four inches that he's saying.

CDD Designee:

If you can wrap upLori Austin:

Okay.

CDD Designee:
... your comments and summarize.

Lori Austin:

Okay, last thing is, this is from my master bedroom window and the deck, right there.

CDD Designee:

Okay.

Lori Austin:

So, and then this is the staking from the inside family room where you could see that my view, here's the other deck that I mentioned, is not as impacted. Only now, the deck extends past... I had to open the window because the reflection back into the window wouldn't let me.

But here's now where the deck is, it is built. Here's where it should have ended over here, right? So I figure this window would've been the impingement, but then there's this added space because it's, I don't know what that's called. Okay?
So, it's not as described, and we would like to present this at a formal design review hearing because this was not built to what we were given in the beginning as their comprehensive full work plan, and it's way beyond the 28-inch scope that they have described.

CDD Designee:

Okay, thank you for your comments. Would the project applicant like to respond? 93 This transcript was exported on Aug 14, 2025 - view latest version here.

Clipped video_31421 Holly Drive (Completed 08/14/25)
Transcript by Rev.com

Page 8 of 9 ends

Dave Frith:

Yes, please. Just real quickly, I'll kind of hit them in the order that Mike and Laurie had shared them. As far as Mike's comment about not following the staking, I simply respectfully disagree. This is a copy of the certified staking.

There's clearly a 10-foot dimension shown on the certified staking plan, and that's further augmented by the fact that there's kind of a curving planter wall and you can see that the stake is basically behind that curving planter wall.

So, I'm not sure where the eight feet is coming from. Our staking plan clearly shows 10 feet. Second, as far as plans not being available, both Mike and Laurie have a relationship with their next-door neighbors as well as the general contractor that I think is actually doing a pretty good job of keeping the neighborhood peace.

The plans should have been available. I'm not sure why they weren't available. I can't speak to that, but would be happy to share them. I would like to comment though that this deck has been staked, has been built for many, many months, and I didn't realize it until I was doing the railing calculations.

They sent me a sign-off on the railing shot drawings and realized that there was 12 feet of railing. And I said, "Roman, this is a 10-foot deck." And he said, "Oh, 10 feet from that deck or non-deck that was two feet."
So, it was, point is it's been constructed that way for a long time. I haven't heard about it, and I'm the one that proactively am coming back to Admin DRB to clean up a mistake that was made on site.

Mike made the comment, another mistake. "Oops, oops, oops. I'm not sure if there have been other mistakes. I'm here to talk about the fact that the deck was built two feet longer than the approved 10- foot plan." It's actually two feet, not two-foot-four, if we want to modify the admin design review application.

Lastly, as far as Laurie, her comment about seeing... Not lastly, sorry, two more. Laurie saying that you can see into my bedroom, that's the design review board's process. These homes are all blessed with a magnificent view, and there were no issues with the adjacency between the side yards. That's an existing condition. Those windows are there, both of these houses are built there.

I'm not here to talk about seeing into her bedroom, I'm here to ask for the administrative approval on a 24-inch deck extension. In my opinion, the security and the privacy and all of those issues were discussed at design review. Two last ones, the dirt moving has nothing to do with this deck. There are landscape permits, there are terraced walls that step down the project that I think Laurie made the comment that all of this excavation or dirt moving had something to do with the deck. That's simply not true.

All of the dirt moving was organized through building inspections and there are no red tags or any improprieties with that. That has nothing to do with the deck. And lastly, the comment about the stucco gray house, I have a picture, I'm not, it's hard to determine, but I have a picture that cites perfectly down where the post is, and in the distance is the front of Mike and Laurie's house.

So I just know that cameras and photographs can be a little bit misleading depending on where you're standing, this, that and the other thing. The original posts are in line with where their gray stucco house is. This cantilevered extension, which is 24 inches more than the approved plan is what we would like to ask for administrative design review board approval.

In my personal opinion, this is small potatoes and hopefully not something that we want to waste design review board's time. I know that's not my decision, but I really don't think that this will be contested and hopefully we don't need to spend a few more months and $4,000 and go through that process. 94 This transcript was exported on Aug 14, 2025 - view latest version here.

Clipped video_31421 Holly Drive (Completed 08/14/25)
Transcript by Rev.com

Page 9 of 9 ends

And we notice, I do know that Mike and Laurie are the only ones that have expressed any concern, and the deck is on the opposite side of their property. And so, I have no further comments unless you have questions.

CDD Designee:

Okay, thank youDave Frith:

Thank you.

CDD Designee:
... for that response. I will now close the public testimony. Based on the comments made and the diagrams presented and reviewing the plans and the administrative record, it appears that we before design review board for the additional 24 or 28 inches of deck that has been constructed but was not on the previous plans.

With respect to decks, the main considerations are of course, view equity and privacy concerns. Because we're only looking at the additional 28 inches, or roughly 67 square feet, it would be my finding that the project can be approved as presented. It is an administrative process to have an elevated deck, and so I am approving the project based on the plans provided in the testimony given.

I understand neighbor's frustration. But the scope before us today is just the portion of the deck that has been constructed but was not shown on the original plans. And with respect to that scope of work, there doesn't appear to be any view equity or privacy concerns. And so the project is approved as presented.

That concludes today's hearing. There is a 14-day right of appeal which will end June 20th. If you have any questions, please reach out to the project planner and that ends today's hearing. Thank you all for attending.

Lori Austin:

Thank you.

Dave Frith:

Thank you very much.

Lori Austin:

Thank you.
95 NOTICE OF A PUBLIC HEARING

LAGUNA BEACH CITY COUNCIL
The Laguna Beach City Council will hold an in-person Public Hearing in the City Council Chambers, located in City Hall at 505 Forest Avenue, Laguna Beach, to consider:

Appeal of approval of Design Review 25-0891 and CEQA Categorical Exemption for an elevated deck addition at 31421 Holly Drive in the R-1 zone.

Related Project Cases on the property include but are not limited to: DR 22-2245, VAR 22-2266 Applicant: Dave Frith
A person has appealed the decision of the Community Development Director Designee to approve the project.

SAID PUBLIC MEETING to be held Tuesday, August 12, 2025, at 5:00 p.m. or as soon thereafter.

For additional information, contact City staff: Daniel Latham, Associate Planner (949) 464-6612 or [email protected]. Comments may be made in writing prior to the hearing (when emailed or mailed to the City Clerk’s office) or in-person in Council Chambers during the public hearing. In order to allow sufficient time for members of the City Council and staff to review and consider your comments, written comments will be accepted for consideration up until the close of business (i.e., 5:30 p.m.) on the business day before the date on which this public hearing is scheduled; however, it is recommended they be submitted to the City Clerk’s office on or before 5:00 p.m. five days prior to the scheduled hearing.

Pursuant to California Government Code Section 65009(b), if you challenge this application in court, the issues raised shall be limited to those raised in the public hearing or in written correspondence delivered to the City of Laguna Beach prior to, or at, the public hearing.

CEQA: This project is categorically exempt pursuant to the California Environmental Quality Act Guidelines, Section 15301 (Existing Facilities).

COASTAL: This project is located in the Coastal Zone. This project is located within a non-appealable area of the Coastal Zone.

The project is proposed as exempt development under Laguna Beach Municipal Code Chapter 25.07. The review procedure identified in Laguna Beach Municipal Code Section 25.07.012(B)(3) applies to any such determination.

Pursuant to the Americans with Disabilities Act, persons with a disability who require a disability-related modification or accommodation in order to participate in a meeting, including auxiliary aids or services, may request such modification or accommodation from the City Clerk’s Office at (949) 497-0705 (telephone) or (949) 497-0771 (facsimile). Notification 48 hours prior to the meeting will enable the City to make reasonable arrangements to assure accessibility to the meeting.

Property Owners within 300 ft./ Tenants within 100 ft./ Property Posted/ Publish Date: 8/1/2025 Attachment 6
96 ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022
PERMIT PLAN CHECK 03.23.2023
PERMIT SET 05.08.2023
DELTA 4 08.06.2024
DELTA 5 01.02.2025
DELTA 6 04.29.2025

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
DELTA 7 06.04.2025

PROJECT SUMMARY TABLES
USE SFR ZONE R1 LOT SLOPE (%) 27%

ZONING STANDARDS

DESCRIPTION REQUIRED EXISTING PROPOSED CONFORMS
LOT AREA 6,000 S.F. 6,874 S.F. NO CHANGE YES
LOT WIDTH 70'-0" 54'-5" NO CHANGE NO
LOT DEPTH 80'-0" 126'-2" NO CHANGE YES
MAX BUILDING HEIGHT 30'-0" 20'-2" NO CHANGE YES
MAX HEIGHT FROM CURB 15'-0" 9'-8" NO CHANGE YES
SETBACKS:

FRONT YARD
5'-0" GARAGE
10'-0" HOUSE
7'-1" GARAGE
26'-11" HOUSE NO CHANGE YES
REAR YARD 20'-0" 50'-0" NO CHANGE YES
SIDE YARDS (E) 54.22' FRONT + 60' REAR = 114.22'
/ 2 = 57.11' AVERAGE WIDTH
* 20%=11.42' TOTAL S.Y.S.B. (11'-5")
4'-4" (4'-9" EXISTING) NO CHANGE YES
SIDE YARDS (W) 7'-1" NO CHANGE YES

LOT COVERAGE
(BSC)
BSC %: 35 + (8000-6874) x 9
/ 4000 = 38%
2,124 S.F. 2,149 S.F. YES 31% 31%

LANDSCAPE OPEN SPACE
1,532 S.F. 4,316 S.F. 4,037 S.F. YES 22% MIN. 63% 59%
PARKING 2 COVERED SPACES 1 COVERED NO CHANGE NO

PROJECT DATA

DESCRIPTION EXISTING PROPOSED TOTAL REMODEL
LIVING AREA:

BASEMENT 602 S.F. 351 S.F. 953 S.F. 140 S.F.

MAIN LEVEL 1,273 S.F. 409 S.F. 1,682 S.F. 200 S.F.

TOTAL 1,875 S.F. 760 S.F. 2,635 S.F. 340 S.F.

GARAGE 279 S.F. NO CHANGE 279 S.F.

ELEVATED DECK 0 S.F. 342 S.F. 342 S.F.

MECHANICAL / STORAGE 351 S.F. -351 S.F. 0 S.F.

DEMOLITION EXISTING REMOVED REMAINING DEMO TOTAL
FLOOR AREA:

BASEMENT 602 S.F. 0 S.F. 602 S.F. 0%
MAIN LEVEL 1,273 S.F. 0 S.F. 1,273 S.F. 0%
ROOF AREA 2,124 S.F. 374 S.F. 1,750 S.F. 18%
TOTAL EXTERIOR WALL 337'-6" L.F. 110'-3" L.F. 227'-3" L.F. 33% FOUNDATION 197'-4" L.F. 49'-10" L.F. 147'-6" L.F. 25%
TOTAL WALL + ROOF +

FOUNDATION
25%

SITE WORK

GRADING (CUBIC YARDS) OUTSIDE BUILDING

FOOTPRINT

INSIDE BUILDING

FOOTPRINT
TOTAL
CUT 0 CUBIC YARDS 0 CUBIC YARDS 0 CU. YD.

FILL 0 CUBIC YARDS 0 CUBIC YARDS 0 CU. YD.

NET EXPORT 0 CUBIC YARDS 0 CUBIC YARDS 0 CU. YD.

IMPERVIOUS SURFACES
LOT AREA % OF LOT AREA

EXISTING PROPOSED EXISTING PROPOSED
STRUCTURE 2,124 S.F. 2,149 S.F. 31% 31%

HARDSCAPE
(INCL. DRIVEWAY) 430 S.F. 702 S.F. 6% 10%
TOTAL 2,554 S.F. 2,851 S.F. 37% 41%

EXTERIOR BUILDING LIGHTING
EXISTING EGRESS DOORS 3 PROPOSED EGRESS DOORS 6
EXISTING FIXTURE COUNT 3 PROPOSED FIXTURE COUNT 15

FIXTURE TYPE WATTAGE LUMUNES QUANTITY COMMENTS
RECESSED STAIR LIGHT 0 365 10
WALL SCONCE 3 365 4
RECESSED SOFFIT LIGHT 0 365 1
TOTAL 15

LANDSCAPE LIGHTING
EXISTING FIXTURE COUNT 10 PROPOSED FIXTURE COUNT 10

FIXTURE TYPE WATTAGE LUMUNES QUANTITY COMMENTS
GARDEN LIGHT 10 365 10
TOTAL 10
COMBINED TOTAL 25

ARCHITECT

BEACH BUS STUDIOS
349 THIRD STREET
LAGUNA BEACH, CA 92651
(949) 376-3080
CONTACT: DAVE FRITH
[email protected]

STRUCTURAL ENGINEER
CORE STRUCTURE, INC.
23172 PLAZA POINTE DR., SUITE 145
LAGUNA HILLS, CA 92653
(949) 954-7244
CONTACT: AMIR DEIHIMI
[email protected]
TITLE 24 ENERGY CONSULTANT

CARSTAIRS ENERGY CALCULATIONS
2238 BAYVIEW HEIGHTS DR, SUITE E
LOS OSOS, CA 93402
(805) 904-9048
CONTACT: TIMOTHY CARSTAIRS
[email protected]

PROJECT CONSULTANTS

PROJECT ADDRESS
31421 HOLLY DR
LAGUNA BEACH, CA 92651
OWNERS

AINA & GORDON MCBEAN
(949) 376-3080
LEGAL DESCRIPTION N TR 713 BLK LOT 205
ASSESSOR PARCEL NO. (APN) 056-061-16
PARCEL ID NO. (PIN) 1036

COUNTY OF ORANGE
ZONE DISTRICT R1

CONSTRUCTION TYPE V-B

BUILDING DOES NOT HAVE A FIRE SPRINKLER SYSTEM

PROJECT INFORMATION

SUMMARY OF EXTERIOR ARCHITECTURAL IMPROVEMENTS

1. ENCLOSE OUTDOOR PATIO, CONVERT TO 396 S.F. OF HABITABLE AREA

2. MAIN LEVEL DECK ADDITION OF 300 S.F.

3. THREE BAY WINDOWS

4. REPLACE AT GRADE EXTERIOR STAIR AT SIDE YARD AND ENTRY

5. NEW STANDING SEAM METAL ROOF TO REPLACE EXISTING

6. NEW HORIZONTAL SIDING

7. NEW DOORS AND WINDOW TO REPLACE EXISTING

8. NEW ROOF AT EXISTING ENTRYWAY

9. NEW NEW 6'Ø PRE-FABRICATED, FREESTANDING, SELF CONTAINED JACUZZI.

10. NEW AC COMPRESSOR

10.5 58 SF ADDITION TO AN EXISTING APPROVED 300 SF DECK

SUMMARY OF INTERIOR ARCHITECTURAL IMPROVEMENTS

11. KITCHEN AND BATHROOM REMODEL

12. REPLACEMENT OF EXISTING WIRING FOR NEW FIXTURES

13. ADDITIONAL DRYWALL REMOVAL TO MATCH DEMO CALCS REV. 1 NOTE:

APPROVED THROUGH DESIGN REVIEW 22-2245 & VARIANCE 22-2266

SCOPE OF WORK

COVER SHEET
A001

SHEET INDEX

GENERAL NOTES

ARCHITECTURAL
A001 COVER SHEET
A002 CAL GREEN (NOT USED)
A003 CAL GREEN (NOT USED)
A004 FIRE DEPARTMENT SITE ACCESS PLAN (NOT USED)
A005 CONSTRUCTION STAGING PLAN (NOT USED)
A006 SITE PLANS
AD00 BASEMENT & GARAGE DEMOLITION PLANS (NOT USED)
AD01 MAIN LEVEL DEMOLITION PLAN (NOT USED)
A100 BASEMENT & GARAGE NEW WORK PLANS (NOT USED)
A101 MAIN LEVEL NEW WORK PLAN
A150 BASEMENT & GARAGE POWER PLANS (NOT USED)
A151 MAIN LEVEL POWER PLAN (NOT USED)
A200 BASEMENT & GARAGE REFLECTED CEILING PLANS (NOT USED) A201 MAIN LEVEL REFLECTED CEILING PLAN (NOT USED)
A300 ROOF PLANS (NOT USED)
A500 EXTERIOR ELEVATIONS (NOT USED)
A501 EXTERIOR ELEVATIONS (NOT USED)
A502 EXTERIOR ELEVATIONS
A503 EXTERIOR ELEVATIONS (NOT USED)
A600 BUILDING SECTIONS (NOT USED)
A601 BUILDING SECTIONS (NOT USED)
A700 STAIR DETAILS (NOT USED)
A800 EXTERIOR DETAILS (NOT USED)
A900 DOOR & WINDOW SCHEDULES (NOT USED)
A901 DOOR & WINDOW DETAILS (NOT USED)
TITLE 24
T-24.1 T-24 ENERGY ANALYSIS (NOT USED)
T-24.2 T-24 ENERGY ANALYSIS (NOT USED)
T-24.3 T-24 ENERGY ANALYSIS (NOT USED)

STRUCTURAL
S-0.10 GENERAL NOTES & REQUIREMENTS (NOT USED)
S-0.11 GENERAL NOTES & REQUIREMENTS (NOT USED)
S-0.20 TYPICAL DETAILS (NOT USED)
S-1.0 FOUNDATION PLAN (NOT USED)
S-2.0 FRAMING PLAN (NOT USED)
SD1.0 FOUNDATION DETAILS (NOT USED)
SD1.1 FOUNDATION DETAILS (NOT USED)
SD2.0 STRUCTURAL DETAILS (NOT USED)
SD3.0 STRUCTURAL DETAILS (NOT USED)
SD4.0 STRUCTURAL DETAILS (NOT USED)

1. ALL CONSTRUCTION SHALL COMPLY WITH, BUT SHALL NOT BE LIMITED TO THE LATEST EDITION AND ORDINANCES OF:

A. CALIFORNIA BUILDING CODE 2022
B. CALIFORNIA RESIDENTIAL CODE 2022
C. CALIFORNIA ELECTRICAL CODE 2022
D. CALIFORNIA MECHANICAL CODE 2022
E. CALIFORNIA PLUMBING CODE 2022
F. CALIFORNIA FIRE CODE 2022
G. CALIFORNIA GREEN BUILDING STANDARDS CODE
H. APPLICABLE SECTIONS OF THE CALIFORNIA ADMINISTRATIVE CODE, TITLE 24 I. 2022 CALIFORNIA BUILDING ENERGY EFFICIENCY STANDARDS

2. A STAMPED SET OF APPROVED PLANS SHALL BE KEPT AT THE JOB SITE AT ALL TIMES.

3. THE CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO THE START OF CONSTRUCTION.

4. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND THE OWNER

PRIOR TO PROCEEDING WITH THE WORK THE CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ERRORS AFTER THE START OF CONSTRUCTION WHICH IS NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT.

5. THE CONTRACTOR IS RESP0NSIBLE FOR PROTECTING ANY ON-SITE UTILITIES FROM DAMAGE DURING THE COURSE OF CONSTRUCTION.

6. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.

7. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY PERMITS AND INSPECTIONS, OTHER THAN PLAN CHECK & BUILDING PERMIT FEES PROVIDED BY THE OWNER.

8. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, EQUIPMENT, TRANSPORTATION AND SERVICES NECESSARY FOR SUCCESSFUL COMPLETION OF THE WORK ALL EQUIPMENT, WORK AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE CODES AND GOVERNING AGENCIES.

9. THE CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT HIMSELF AND HOLD THE ARCHITECT AND OWNER HARMLESS FROM ANY AND ALL CLAIMS FOR DAMAGES FOR PERSONAL, BODILY INJURY, DEATH OR PROPERTY DURING THE COURSE OF THE CONTRACT. FIRE INSURANCE SHALL BE MAINTAINED BY THE OWNER.

10. TEMPORARY POWER AND WATER, WORKERS' TOILET FACILITIES, PARKING AND MATERIAL STORAGE SHALL BE PROVIDED BY THE CONTRACTOR.

11. THE CONTRACTOR SHALL PROTECT ALL FINISHED WORK AND ADJACENT SURFACES FROM DAMAGE DURING THE COURSE OF CONSTRUCTION AND SHALL REPLACE AND/OR REPAIR ANY AND ALL DAMAGE CAUSED BY THE WORKERS.

12. ALL CONSTRUCTION WASTE & DEBRIS MUST BE CONTAINERIZED AT ALL TIMES. UPON COMPLETION OF THE WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN AND ALL DEBRIS SHALL BE REMOVED FROM THE SITE.

13. RECESSED BOXES, EQUIPMENT, CABINETS AND THE LIKE, 8" X 8" OR LARGER, IN "1 - HOUR RATED WALLS", SHALL MAINTAIN A 1-HOUR CONSTRUCTION RATING.

14. DIMENSIONS SHOWN ON FLOOR PLANS, SECTIONS AND DETAILS ARE TO FACE OF STUDS, CENTERLINE OF COLUMN, FACE OF MASONRY, FACE OF CONCRETE UNLESS NOTED OTHERWISE.

15. DOOR LOCATIONS NOT ESTABLISHED BY DIMENSIONS SHALL BE CENTERED IN WALL OR BE LOCATED 4 1 2" FROM ADJACENT WALL TO ALLOW FOR DOOR CASING.

16. ANY DRILLING OR NOTCHING OF STUDS FOR ELECTRICAL WIRING, UTILITY LINES, BRACING ETC. SHALL CONFORM TO LOCAL CODE.

17. ALL GUARDRAILS SHALL BE A MINIMUM OF 42" HIGH. INTERMEDIATE MEMBERS SHALL NOT ALLOW A 4" DIAMETER OBJECT TO PASS THROUGH.

18. PROVIDE A MINIMUM STUD SIZE OF 2 X 6 WHERE USING 2" PLUMBING FIXTURES.

19. PROVIDE FULLY TEMPERED IMPACT GLAZING AT SHOWER/TUB ENCLOSURES AND AT WINDOWS ADJACENT TO BATHTUBS.

20. ALL NEW GLAZING SHALL COMPLY WITH STANDARDS OF THE U.S. CONSUMER PRODUCT SAFETY COMMISSION. MANUFACTURER TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER.

21. ALL TOILETS SHALL BE "ULTRA FLUSH" TYPE AS REQUIRED BY STATE. ALL SHOWER HEADS AND LAVATORY FAUCETS TO BE LOW FLOW.

22. GARAGE DOOR SPRINGS TO BE STATE APPROVED WITH BREAK RETAINERS AND MANUFACTURERS LABELS.

23. ALL INTERIOR FINISH MATERIALS SHALL MEET CLASS III FLAME SPREAD CLASSIFICATION, PER LOCAL CODE.

24. NAILING INSPECTION IS REQUIRED FOR ALL DRYWALL AND LATH AFTER INSTALLATION BEFORE TAPING AND FINISHING. CORNER BEADS TO BE NAILED.

DRYWALL BOARD SPACING TO BE 3/8" MAXIMUM.

25. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES,TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE CONSTRUCTION SHALL NOT BE WITHIN TEN FEET FROM ANY POWER LINES - WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.

26. EQ EMERGENCY GAS SHUT OFF VALVES TO BE INSTALLED ON ALL GAS FUEL LINES.

27. THE ARCHITECT SHALL BE PROVIDED A KEY OR COMBINATION TO THE LOCK ON JOB SITE GATES FOR ACCESS TO THE CONSTRUCTION SITE AT ALL TIMES.

28. MECHANICAL SUBCONTRACTOR TO PROVIDE THE ARCHITECT WITH A SCHEMATIC LAYOUT FOR ALL MECHANICAL UNITS, DUCT RUNS, AND REGISTER LOCATIONS AND SIZES FOR REVIEW AND APPROVAL PRIOR TO ANY MECHANICAL ROUGH IN.

29. PROVIDE STRUCTURAL OBSERVATION PER CITY OF LOS ANGELES REQUIREMENTS.

30. DRAFT STOPPING (AT 10' INTERVALS HORIZONTAL AND VERTICAL SHALL BE PROVIDED WITHIN A CONCEALED FLOOR/CEILIING ASSEMBLY FORMED OF

COMBUSTIBLE CONSTRUCTION, ATTICS, MANSARDS, OVERHANGS, OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, BETWEEN ATTIC AND CHIMNEY CHASE, AT STAIR STRINGERS, AND SIMILAR CONCEALED SPACES FORMED OF COMBUSTIBLE CONSTRUCTION PER LOCAL CODE.

31. ENCLOSED USEABLE SPACE UNDER INTERIOR STAIRS REQUIRES 1-HOUR FIRE RESISTIVE CONSTRUCTION ON THE ENCLOSED SIDE PER LOCAL CODE.

32. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND; OR OBTAIN A NECESSARY PERMIT FROM STATE OF CALIFORNIA, DIVISION OF OCCUPATIONAL SAFETY & HEALTH (CAL/OSHA, 714-558-4451). THIS PERMIT AND ANY OTHER SAFETY PERMIT SHALL BE OBTAINED PRIOR TO COMMENCE OF ANY WORK.

NORTH
31421 HOLLY DR
LAGUNA BEACH, CA 92651

VICINITY MAP REFERENCE ONLY

MCBEAN RESIDENCE
31421 HOLLY DR,
LAGUNA BEACH, CA 92651

1. THE PERMIT APPLICATION FOR THIS PROJECT IS DEEMED TO HAVE BEEN EXPIRED 180 DAYS AFTER THE DATE FILING .

CONTACT COUNTY BUILDING DEPARTMENT TO OBTAIN WRITTEN 180-DAY EXTENSION(S). [CRC R105.3.2]

2. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND; OR OBTAIN A NECESSARY PERMIT FROM STATE OF CALIFORNIA, DIVISION OF OCCUPATIONAL SAFETY & HEALTH (CAL/OSHA, 714-558-4451). THIS PERMIT AND ANY OTHER SAFETY PERMIT SHALL BE OBTAINED PRIOR TO COMMENCE OF ANY WORK.

3. NEW ONE-FAMILY DWELLINGS SHALL HAVE AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH CRC SECTION R313.3 OR NFPA 13D. SUBMIT 3 SETS OF AUTOMATIC SPRINKLER PLANS TO OFCA FOR APPROVAL (714) 573-6100 [CRC R313]

4. THE SUPPORTING CONSTRUCTION OF FLOOR ASSEMBLIES WITH FIRE RESISTANCE RATED BY SECTION R302.3 SHALL BE OF EQUAL OR GREATER FIRE-RESISTANCE RATING THAN THE FIRE-RATED ASSEMBLY BEING SUPPORTED. [CRC R302.3.1]

5. THROUGH PENETRATIONS OF FIRE-RESISTANCE-RATED CONSTRUCTION SHALL BE IN ACCORDANCE WITH CRC R302.4.1.1 OR R302.4.1.2.

6. MEMBRANE PENETRATIONS OF FIRE-RATED CONSTRUCTION SHALL BE IN ACCORDANCE WITH CRC SECTION R302.4.2.

7. FIREBLOCKING IS REQUIRED IN CONCEALED SPACES 10' O.C. HORIZONTAL, VERTICALLY AT THE CEILING AND FLOOR

LEVELS, CONNECTIONS BETWEEN HORIZONTAL AND VERTICAL SPACES, CONCEALED SPACES BETWEEN STAIR AND LANDING, OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES, WIRES, CHIMNEY'S AND FIREPLACES. [CRC R302.11]

8. ALL WOOD FRAMING MEMBERS THAT REST ON CONCRETE OR MASONRY EXTERIOR FOUNDATION WALLS AND ARE LESS THAN 8" TO THE EXPOSED GROUND SHALL BE PRESSURE TREATED OR NATURALLY DURABLE TO DECAY. [CRC R317.1, ITEM 1]

9. SILLS AND SLEEPERS IN DIRECT CONTACT WITH CONCRETE OR MASONRY THAT IS IN DIRECT CONTACT WIHT THE GROUND AND GIRDERS WITH LESS THAN 1/2" CLEARANCE TO MASONRY AND CONCRETE SHALL BE PRESSURE TREATED OR NATURALLY DURABLE TO DECAY. [CRC R317.1, ITEM 3&4]

10. FIELD CUTTING ENDS, NOTCHES AND DRILLED HOLES OF PRESERVATIVE-TREATED WOOD SHALL BE TREATED IN THE FIELD IN ACCORDANCE WITH AWAP M4. [CRC R317.1.1]

11. THE MIN. WIDTH OF HALLWAYS SHALL NOT BE LESS THAN 36". [CRC R311.6]

12. AN ELEVATOR PERMIT WILL BE REQUIRED FROM THE ELEVATOR DIVISION OF CAL/OSHA.

13. IT IS THE CONTRACTOR OR OWNER RESPONSABILITY TO PROVIDE ONE HARD SET OF PLANS WITH THE COUNTY APPROVAL STAMP IN THE FIELD FOR THE INSPECTOR TO VIEW.

GENERAL NOTES

1. IN CASE OF EMERGENCY CALL DAVE FRITH, 949-370-3723

2. SEDIMENT FROM AREAS DISTURBED BY CONSTRUCTION SHALL BE RETAINED ON SITE USING STRUCTURAL CONTROLS TO THE MAXIMUM EXTENT PRACTICABLE.

3. STOCKPILES OF SOIL SHALL BE PROPERLY CONTAINED TO MINIMIZE SEDIMENT TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES OR ADJACENT PROPERTIES VIA RUNOFF, VEHICLE TACKING, OR WIND.

4. APPROPRIATE BMP'S FOR CONSTRUCTION-RELATED MATERIALS, WASTES, SPILLS SHALL BE IMPLEMENTED TO

MINIMIZE TRANSPORT FROM THE SITE TO STREETS, DRAINAGE FACILITIES, OR ADJOINING PROPERTIES BY WIND OR RUNOFF.

5. RUNOFF FROM EQUIPMENT AND VEHICLE WASHING SHALL BE CONTAINED AT CONSTRUCTION SITES UNLESS TREATED TO REDUCE OR REMOVE SEDIMENT AND OTHER POLLUTANTS.

6. ALL CONSTRUCTION CONTRACTOR AND SUBCONTRACTOR PERSONNEL ARE TO BE MADE AWARE OR THE REQUIRED

BEST MANAGEMENT PRACTICES AND GOOD HOUSEKEEPING MEASURES FOR THE PROJECT SITE AND ANY ASSOCIATED CONSTRUCTION STAGING AREAS.

7. AT THE END OF EACH DAY OF CONSTRUCTION ACTIVITY ALL CONSTRUCTION DEBRIS AND WASTE MATERIALS SHALL BE COLLECTED AND PROPERLY DISPOSED IN TRASH OR RECYCLE BINS.

8. CONSTRUCTION SITES SHALL BE MAINTAINED IN SUCH A CONDITION THAT AN ANTICIPATED STORM DOES NOT CARRY WASTES OR POLLUTANTS OFF THE SITE. DISCHARGES OF MATERIAL OTHER THAN STORMWATER ONLY

WHEN NECESSARY FOR PERFORMANCE AND COMPLETION OF CONSTRUCTION PRACTICES AND WHERE THEY DO NOT: CAUSE OR CONTRIBUTE TO A VIOLATION OF ANY WATER QUALITY STANDARD; CAUSE OR THREATEN TO CAUSE POLLUTION, CONTAMINATION, OR NUISANCE; OR CONTAIN A HAZARDOUS SUBSTANCE IN A QUANTITY REPORTABLE UNDER FEDERAL REGULATIONS 40 CFR PARTS 117 AND 302.

9. POTENTIAL POLLUTANTS INCLUDE BUT ARE NOT LIMITED TO: SOLID OR LIQUID CHEMICAL SPILLS; WASTES FROM PAINTS, STAINS, SEALANTS, GLUES, LIMES, PESTICIDES, HERBICIDES, WOOD PRESERVATIVES AND SOLVENTS; ASBESTOS FIBERS, PAINT FLAKES OR STUCCO FRAGMENTS; FUELS, OILS, LUBRICANTS, AND HYDRAULIC, RADIATOR OR BATTERY FLUIDS; FERTILIZERS, VEHICLE/EQUIPMENT WASH WATER AND CONCRETE WASH WATER; CONCRETE, DETERGENT OR FLOATABLE WASTES; WASTES FROM ANY ENGINE/EQUIPMENT STEAM CLEANING OR CHEMICAL DEGREASING AND SUPERCHLORINATED POTABLE WATER LINE FLUSHING.

DURING CONSTRUCTION, PERMITTEE SHALL DISPOSE OF SUCH MATERIALS IN A SPECIFIED AND CONTROLLED

TEMPORARY AREA ON-SITE, PHYSICALLY SEPARATED FROM POTENTIAL STORMWATER RUNOFF, WITH ULTIMATE DISPOSAL IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL REQUIREMENTS.

10. DEWATERING OF CONTAMINATED GROUNDWATER, OR DISCHARGING CONTAMINATED SOILS VIA SURFACE EROSION IS PROHIBITED. DEWATERING OF NON-CONTAMINATED GROUNDWATER REQUIRES A NATIONAL POLLUTANT

DISCHARGE ELIMINATION SYSTEM PERMIT FROM THE RESPECTIVE STATE REGIONAL WATER QUALITY CONTROL BOARD.

NPDES NOTES

EXHIBIT 'B'

CONDITIONS OF APPROVAL
Standard Conditions:

1. The conditions of approval shall be and hereby are obligations of and binding upon the applicant and his/her heirs, successors, assigns, agents and representatives. The conditions shall constitute a covenant running with and binding the land in accordance with the provisions of California Civil Code Section 1468. Failure to comply with such conditions, and each of them, and any other related federal, state and local regulations may be grounds for revocation of the approval, in addition to other remedies that may be available to the City.

2. The applicable Certificate of Use and/or Certificate of Occupancy shall not be issued until City staff has verified compliance with all conditions of approval.

3. Prior to Building Permit issuance, the owner, his architect/designer/structural engineer, and contractor of the subject property shall sign an Affidavit of Plan Consistency, whereby the signees affirm that the structural plans are consistent with the Zoning Division-approved set of plans and any modification will require subsequent review and approval.

4. In the absence of specific provisions or conditions herein to the contrary, the application and all relevant plans and exhibits are incorporated and made a part of this approval. It is required that such plans and exhibits be complied with and implemented in a consistent manner with the approved use and other conditions of approval. Such plans and exhibits for which this approval has been granted shall not be substantially changed or substantially amended except pursuant to a subsequent approval as might otherwise be required or granted pursuant to the terms of Title 25 of the City of Laguna Beach Municipal Code.

5. The permittee shall defend, hold harmless and indemnify, at his/her/its expense, the City, the City Council and other City bodies and members thereof, officials, officers, employees, agents and representatives (collectively, the City) from and against any and all third-party claims, actions or proceedings to attack, set aside, void or annul this approval, or any associated determination made pursuant to the California Environmental Quality Act. This obligation shall encompass all costs and expenses incurred by the City in defending against any claim, action or proceeding, as well as costs, expenses or damages the City may be required by a court to pay as a result of such claim, action or proceeding.

6. Expiration. This approval shall lapse and become void two years following the effective date if the privileges authorized by design review are not executed or utilized or, if construction work is involved, such work is not commenced within such two-year period and diligently pursued to completion. The approval authority may grant a two-year extension of time and, after that initial extension of time, a final one-year extension of time. Such time extensions shall be requested in writing by the applicant or authorized agent prior to the expiration of the beginning two-year approval period or a subsequently approved extension of time.

7. Reapplication Waiting Period. After denial of a project, no application for a project located on the same parcel or building site may be filed or accepted for filing for two months.

8. Light trespass that results in glare is prohibited.

9. Outdoor lighting must be hooded, fully shielded, and aimed downward.

10. Modifications. Additions or enlargements of structures upon property for which a variance has been granted shall not be allowed except pursuant to a subsequent variance as might otherwise be required or granted pursuant to the terms of Title 25 of the City of Laguna Beach Municipal Code.

Project Specific Special Conditions:

1. The five-foot fence proposed along Holly Drive shall be constructed according to the 2022 California Building Code requirements for a non-climbable fence that secures a swimming pool/spa, and include the self-latching requirements for the front access gate.

DRAFT DRB RESOLUTION 22-2245

A RESOLUTION OF THE OF THE DESIGN REVIEW BOARD OF THE CITY OF LAGUNA BEACH, CALIFORNIA APPROVING DESIGN REVIEW 22-2245, AND VARIANCE 22-2266, FOR A 760 SQUARE FOOT ADDITION, A 300 SQUARE FOOT BALCONY, A VARIANCE FOR NOT MEETING THE REQUIRED

PARKING ONSITE AND APPROVING CATEGORICAL EXEMPTION PURSUANT TO CALIFORNIA ENVIRONMENTAL QUALITY ACT.
31421 Holly Drive | APN: 056-061-16
WHEREAS, on January 31, 2023, a notice was mailed to all property owners within a 300' radius and tenants within a 100' radius announcing the February 23, 2023, public hearing of the Design Review Board for the proposed project; and WHEREAS, on February 23, 2023, the Design Review Board carefully considered the oral and documentary evidence and arguments presented at the duly noticed hearing.

NOW, THEREFORE, THE DESIGN REVIEW BOARD OF THE CITY OF LAGUNA BEACH DOES HEREBY FIND, DETERMINE AND RESOLVE AS FOLLOWS:

Section 1: Design Review 22-2245, and Variance 22-2266 for a 760 square foot addition (first level: 351 SF; second level:
409 SF) to an existing 1,875 square foot single-family residence, the removal of an existing chimney, a new 300 square foot second-level rear balcony, new doors/windows, a new bay window, a new above ground spa, a 340 square foot internal remodel that includes the conversion of a bedroom into a new master bathroom, new metal roofing, a new AC unit, replacement of siding, and a variance for the proposed addition without meeting the required parking onsite ("Proposed Project") is approved. The proposed project is exempt from the provisions of the California Environmental Quality Act in accordance with State CEQA Guidelines Section 15301 - Existing Facilities, in that the project consists of the repair, maintenance, or minor alteration of existing structures or topographical features, involving negligible or no expansion of existing or former use.; and
Section 2: The proposed project is consistent with the applicable Laguna Beach Municipal Code Title 25 development standards and guidelines as outlined in the Zoning Review section of the Staff Report.

Section 3: The proposed project is consistent with the Design Review criteria related to access, design articulation, design integrity, environmental context, general plan compliance, landscaping, lighting, neighborhood compatibility, privacy, sustainability, and view equity as outlined in the Design Review section of the Staff Report.

Section 4: The Variance findings can be made for the Proposed Project for the reasons and factual basis set forth in the Variance section of the Staff Report.

Section 5: The project is in conformity with all the applicable provisions of the general plan and any applicable specific plans for the reasons and factual basis set forth in Exhibit A of the Staff Report.

Section 8: Terms and Conditions Run with the Land. These terms and conditions shall be perpetual, and it is the intention of the approval authority and the permittee to bind all future owners and possessors of the subject property to the terms and conditions.

Section 9: Indemnification. The permittee shall defend, hold harmless and indemnify, at his/her/its expense, the City, the City Council and other City bodies and members thereof, officials, officers, employees, agents and representatives (collectively, the City) from and against any and all third-party claims, actions or proceedings to attack, set aside, void or annul the approval of this application for Design ReviewDesign Review, or any associated determination made pursuant to the California Environmental Quality Act. This obligation shall encompass all costs and expenses incurred by the City in defending against any claim, action or proceeding, as well as costs, expenses or damages the City may pay as a result of such claim, action or proceeding. In the event an action or proceeding is filed in court against the City, the Design Review, or any associated determination, the permittee shall promptly be required to execute a formal indemnification agreement with the City, in a form approved by the City Attorney, which shall include, among other things, that the City will be defended by the counsel of its choice, and that the permittee shall deposit with the City sufficient funding, and thereafter replenish the funding, to ensure that the City's defense is fully funded, by the permittee. The deposit amount and replenishment schedule shall be established by the City.

Section 10: Plan Reliance and Modification Restriction. In the absence of specific provisions or conditions herein to the contrary, the attached Staff Report and its Exhibits 'A', and 'B', are incorporated and made a part of this Resolution. It is required that the Exhibits 'B' be complied with and implemented in a manner consistent with the approved use and other conditions of approval. Such exhibits for which this permit has been granted shall not be changed or amended except pursuant to a subsequent amendment to the permit or new permit as might otherwise be required or granted pursuant to the terms of Title 25 of the Laguna Beach Municipal Code.

Section 11: Grounds for Revocation or Modification. Failure to abide by and faithfully comply with Exhibits 'B' and 'C' attached to the granting of the proposed project may constitute grounds for revocation or modification of the permit.

Section 12: Right of Appeal and Effective Date. The applicant or any other owner of property within three hundred feet of the subject property aggrieved by the Design Review Board's decision on Design Review 22-1451 or Variance 22-1928 may appeal such decision to the City Council. The Design Review Board's determination to approve a Categorical Exemption under CEQA may be appealed by any person to the City Council. Any appeal shall be in written form filed with the City Clerk within fourteen calendar days of the decision and shall specifically state each and every ground for the appeal and be accompanied by payment of the required appeal fee. If no appeal is filed timely, the Design Review Board decision will be effective 14 calendar days after the date of the decision.

1. Section 13: For the foregoing reasons and based on the information and findings included in the Staff Report, Minutes and records of proceedings, the Design Review Board of the City of Laguna Beach hereby approves the proposed project, subject to the conditions of approval and plans in the attached Exhibits 'B'.

PASSED on February 23, 2023, by the following vote:
7 7
7 97

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022
PERMIT PLAN CHECK 03.23.2023
PERMIT SET 05.08.2023
DELTA 4 08.06.2024
DELTA 5 01.02.2025
DELTA 6 04.29.2025

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
DELTA 7 06.04.2025
190'
180'
170'
200'
1 2:12
1:12
1:12 126'-2" LOT DEPTH
31421 HOLLY DRIVE
4'-4"
7'-1"
S.Y.S.B.

S.Y.S.B.
7'-1" 5'-1"
7'-4"
4'-9"
20'-0" R.Y.S.B. 7'-1" 26'-11"
TERRACED LANDSCAPE AREA 50'-0" 73'-0"
1 2:12
31441 HOLLY DRIVE
31411 HOLLY DRIVE
℄ HOLLY DRIVE
℄ OCEAN VIEW STREET

EXISTING AREA OF

ROOF TO BE

DEMOLISHED

SHOWN DASHED

EXISTING CHIMNEY

TO BE REMOVED

54.22' 139.52'
60' 113.81' 17'-6"
17'-6"

EXISTING STAIRS

AND GATE TO BE

REPLACED

EXISTING STAIRS

TO BE REPLACED

EXISTING TERRACED

LANDSCAPE WALLS TO BE
CUTBACK FOR NEW STAIR 10'-0" F.Y.S.B. 5'-0" REDUCED GARAGE F.Y.S.B. 10'-0" F.Y.S.B.

EXISTING

STONE PATH

EXISTING

RETAINING WALL
T.O. EXISTING

NON-STRUCTURAL

RETAINING WALL
= 185'-6"

TO BE REMOVED

AND REPLACED
T.O. EXISTING
WALL = 208'-6"
T.O. EXISTING
WALL = 202'-6"
T.O. EXISTING
CURB = 206'-0"
T.O. EXISTING
WALL = 199'-6"
T.O. EXISTING
WALL = 204'-0"
T.O. MAIN LEVEL F.F.
197'-3"
T.O. BASEMENT F.F.
188'-7"
T.O. GARAGE F.F.
206-3"
T.O. EXISTING
WALL = 201'-0" T.O. PATIO F.S.
196'-10"

EXISTING CHIMNEY

TO BE REMOVED
54'-5" LOT WIDTH 139'-0
1 2
"
T.O. EXISTING
WALL = 188'-3"
190'
180'
170'
200'
x x x x x x
1'-0"
13'-2" 19'-5" 10'-0" F.Y.S.B. 73'-0" 50'-0" 26'-11"
4'-9"
7'-4"
5'-1"
S.Y.S.B.

S.Y.S.B.
7'-1"
4'-4"

CANTILEVERED
BAY WINDOW 113.81'
60' 139.52'

54.22'
NEW 5' HIGH WOOD

FENCE AND GATE

NEW AT GRADE
STAIR
NEW 6'-0" HIGH

WOOD FENCE

1. GENERAL CONTRACTOR TO VERIFY AND REVIEW

EXISTING SITE DRAINAGE REQUIREMENTS WITH

ARCHITECT TO DETERMINE IF THE SYSTEM
PROVIDES ADEQUATE SITE DRAINAGE.

2. OBTAIN A SEPARATE PERMIT FOR RETAINING
WALLS, GRADING, AND SHORING (IF REQUIRED).

3. VERIFY EXACT HARDSCAPE AND PLANT MATERIAL

LAYOUTS, MATERIALS AND SPECIFICATIONS WITH
THE ARCHITECT AND LANDSCAPE ARCHITECT.

4. SUBMIT ACTUAL SAMPLES OF ALL FINISH

MATERIALS TO THE OWNER AND ARCHITECT FOR

REVIEW AND APPROVAL PRIOR TO PURCHASE AND
INSTALLATION.

5. FIELD VERIFY WITH ARCHITECT ALL SITE POWER
AND FINISHED SITE LIGHTING LOCATIONS.

GENERAL NOTES
℄ OCEAN VIEW STREET
31411 HOLLY DRIVE
31441 HOLLY DRIVE
℄ HOLLY DRIVE 3:12 3:12

TERRACED LANDSCAPE AREA
31421 HOLLY DRIVE
1:12
1:12
1 2:12

BUILDING SETBACK

SITE WALL
FENCE

PROPERTY LINE

SITE PLAN LEGEND
20'-0" R.Y.S.B. 7'-1" 17'-6"
17'-6"
TRASH
STORAGE 5'-6"

AC UNIT NOISE ANALYSIS
SOUND RATING OF EQUIPMENT 76 dB
+ EQUIPMENT LOCATION FACTOR <3 dB>
- BARRIER SHIELDING FACTOR <--->
- DISTANCE FACTOR <23.5>
- SOUND ATTENUATION REDUCTION <6dB>
TOTAL 76-26.5 = 49.5 dB (COMPLIES WITH CITY OF LB REQ.) 5'-0" REDUCED GARAGE F.Y.S.B.

REFERENCE SHEET A501
DETAIL #3 FOR SOUND

ATTENUATION TECHNIQUES
REFERENCE SHEET A501
DETAIL #4 FOR

MANUFACTURER'S

SPECIFICATION SHEET
7'-3"
PARKING SPACE #1
8'-8"x18'-0"

EXISTING

STONE PATH

EXISTING

RETAINING WALL
T.O. EXISTING WALL
BELOW = 188'-3"
T.O. NEW WALL =
185'-6" TO REPLACE
(E) NON-STRUCTURAL
WALL

NEW AT GRADE
STAIR
NEW 4' HIGH WOOD

FENCE AND GATE
T.O. MAIN LEVEL F.F.
197'-3"
T.O. BASEMENT F.F.
188'-7"
T.O. GARAGE F.F.
206-3"
T.O. EXISTING
WALL = 208'-6"
T.O. EXISTING
CURB = 206'-0"
4'-0"
T.O. PATIO F.S.
196'-10"
PROVIDE 5' HIGH WOOD POOL SECURITY
FENCING PER LBMC 25.50.016 AND LBMC

25.50.012 (A). THE FENCE SHALL HAVE

SELF-CLOSING GATES AT LEAST FIVE FEET
HIGH WITH SELF-LATCHING MECHANISM.

LATCHES SHALL BE INSTALLED AT LEAST
FOUR FEET ABOVE GROUND LEVEL.

NEW 6'Ø PRE-FABRICATED,

FREESTANDING, SELF CONTAINED
JACUZZI. JACUZZI TO BE COVERED

WITH LOCKABLE COVER WHEN NOT
IN USE. AN AUTOMATIC FILL DEVICE
IS NOT TO BE USED.
17" HIGH STEP / SEAT
AROUND 6' Ø JACUZZI
5'-0"
54'-5" LOT WIDTH 139'-0
1 2
"
F.G. = 185-9"
DN
(N) 6'-0" RETAINING WALL
DETAIL 6/S-0.20
(N) V-DITCH FOR

DRAINAGE
4'-4" S.Y.S.B.

EXISTING APPROVED
24" DECK EXPANSION
4T @ 12"
5R @ 6" 10'-0"
7'-1" S.Y.S.B. 126'-2" LOT DEPTH

SITE PLANS
A006
1 1/8" = 1'-0"

EXISTING SITE PLAN
NORTH
2 1/8" = 1'-0"

PROPOSED SITE PLAN
NORTH
7 7
98 DOOR & FRAME REFERENCE,

REFER TO DOOR & FRAME
SCHEDULE ON A900

NEW DOOR

EXISTING WALL &

DOOR TO REMAIN

NEW PARTITION WALL

FLOOR PLAN LEGEND

ROOM NUMBER

ROOM NAME ROOM
NAME
100

ELEVATION REFERENCE

SHEET NUMBER

VIEW NUMBER

KEYNOTES
MECHANICAL / PLUMBING (INSTALL PER MFR. REQUIREMENTS)
P1 WATER CLOSET - MAXIMUM 1.28 GALLON PER FLUSH. CONFIRM WITH OWNER AND ARCHITECT FOR FLOOR MOUNT OR WALL MOUNT SPEC.

P2
SINK & FAUCET - VERIFY MFR. & MODEL WITH OWNER & ARCHITECT.

CONFIRM MOUNTING STYLE WITH OWNER AND ARCHITECT. PROVIDE GARBAGE DISPOSAL WHERE REQUIRED. INSTALL PER MFR. SPEC'S P3
SHOWER VALVE - VERIFY HEAD QUANTITY, LOCATION, MFR. & MODEL WITH OWNER AND ARCHITECT. INSTALL PER MFR'S SPECIFICATIONS.

CONTROL VALVE FOR SHOWER SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE (418 CPC)

SHOWER DRAIN TO BE INFINITY LINEAR DRAIN
P4
SOAKING TUB & VALVE, VERIFY MFR. & MODEL WITH OWNER. INSTALL PER MFR'S SPEC'S. CONTROL VALVE FOR BATHTUB SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE (418 CPC)
P5 HOSE BIB - MOUNT IN RECESSED CABINET, CONFIRM LOCATIONS WITH

OWNER AND ARCHITECT
P6 OUTDOOR SHOWER
P7 POT FAUCET
P8

WATER HEATER - AMERICAN WATER HEATERS RESIDENTIAL GAS
HIGH-EFFICANCY POWER DIRECT VENT 75 GAL., MODEL VG6275T100NV, PER T-24. PROVIDE RECIRCULATING PUMP. WATER HEATER MUST BE STRAPPED TO WALL. PROVIDE AIR FOR COMBUSTION & VENTILATION PER CMC 701, INSTALL PER MFR'S SPEC'S. SEE A151 LOWER LEVEL POWER PLAN FOR MORE INFORMATION. PROVIDE 3 INCH CLEARANCE ON ALL SIDES, BACK AND TOP AND 6 INCHES IN FRONT. ALL WATER HEATER

INSTALLATION LOCATIONS, REGARDLESS OF PROPOSED WATER HEATING SYSTEM, SHALL HAVE: (BEES 150.0(n)1A-D)
P9
AC PRO ALLIED #4AC16L36P-50A 14 SEER CONDENSING UNIT. AC UNIT TO MAINTAIN A 5-FOOT CLEARANCE FROM ALL PROPERTY LINES. MAXIMUM DECIBEL LEVEL TO BE 60 DB DURING THE DAY AND 50 DB AT NIGHT.

PROVIDE SOUND ATTENUATION AND SHOCK ABSORBENT BASE AS
REQUIRED., INSTALL PER MFR'S SPEC'S. (13.00 SEER/10.00 EER, MIN.) P10

CARRIER INDOOR DUCTED HEATING & COOLING MULTI-ZONE AIR HANDLER UNIT, (95% AFUE, MIN.) PER T-24, PROVIDE AIR FOR COMBUSTION & VENTILATION PER CMC 701, INSTALL PER MFR'S SPECS. PROVIDE 3" CLEARANCE ON ALL SIDES, BACK AND TOP AND 6" IN FRONT. ANCHOR FAU PER CMC 303.4 AND MFR'S INSTRUCTIONS
P11

HIGH EFFICIENCY TANKLESS WATER HEATER - WATER HEATER TO BE WALL MOUNTED. PROVIDE AIR FOR COMBUSTION & VENTILATION PER CMC 701, INSTALL PER MFR'S SPEC'S.

CABINETS
C1 CLOSET MILLWORK - VERIFY LAYOUT, STYLE & FINISH WITH OWNER AND ARCHITECT.

C2

FLOOR & WALL MOUNTED CABINETS & MILLWORK, VERIFY LAYOUT, STYLE & FINISH WITH OWNER AND ARCHITECT. AT BASE CABINETS PROVIDE

STONE SLAB COUNTERTOP & BACK SPLASH, VERIFY SPECIFICATION WITH

OWNER & ARCHITECT

APPLIANCES (INSTALL PER MANUFACTURER REQUIREMENTS)
A1 WASHER - PROVIDE RECESSED PAN & FLOOR DRAIN
A2
DRYER - 4" MIN. VENT TO OUTSIDE, EQUIPPED WITH A BACK-DRAFT DAMPER. MAX DUCT LENGTH 14' WITH (2) 90° BENDS FOR MTL. DUCT, INSTALL PER CMC 504.3.1.2 & MFR'S SPEC'S.

A3 DISHWASHER - INSTALL PER MFR'S SPEC'S
A4 SUB-ZERO REFRIGERATOR/FREEZER
A5

RANGE & HOOD - WOLF DUAL FUEL RANGE & WOLF PRO WALL DUCTED EXHAUST HOOD. MINIMUM 100 CFM PER CMC 504.2 & ASHRA 62.2. MAX.

SOUND RATING OF 2 SONE @ 100 CFM. INSTALL PER MFR'S SPEC'S.

PROVIDE SMOOTH METAL SURFACE ON INTERIOR OF DUCTED EXHAUST HOOD.

A6 WOLF MICROWAVE OVEN DRAWER
A7 WOLF 30" BUILT-IN OVEN
A8 UNDERCOUNTER SUBZERO REFRIGERATOR

FINISHES
F1 TILE SHOWER WALLS & FLOOR - VERIFY SIZE, PATTERN & STYLE WITH

OWNER AND ARCHITECT, INSTALL PER MANUFACTURER'S SPECIFICATION F2

STONE TILE FLOOR - VERIFY SIZE, PATTERN & STYLE WITH OWNER AND

ARCHITECT, INSTALL PER MANUFACTURER'S SPECIFICATION
F3 WOOD FLOORING - CONFIRM SPECIFICATION WITH OWNER AND

ARCHITECT
F4 NOT USED

MISCELLANEOUS
M1 FRAMELESS GLASS - PROVIDE SAFETY GLASS
M2 DRYER COMPARTMENT MAKEUP AIR VENT, 100 SQ. IN. PER CMC 504.3.1 M3 CABLE HANDRAIL/GUARDRAIL - 42" HIGH, CONFIRM FINISH AND STYLE

WITH OWNER AND ARCHITECT
M4 NOT USED
M5

GARAGE SHALL BE SEPARATED FROM THE RESIDENCE AND IT'S ATTIC, STRUCTURE(S) SUPPORTING FLOOR/CEILING ASSEMBLIES BY 5
8" GYPSUM
BOARD APPLIED TO THE GARAGE SIDE, PER CRC R302.6.

M6 PROVIDE SCHLUTER-DITRA-HEAT ELECTRIC FLOOR WARMING SYSTEM AT THE ENTIRE BATHROOM AREA, INSTALL PER MFR'S SPEC'S.

M7

AT ENCLOSED ACCESSIBLE SPACES UNDER STAIRS THE WALLS,

UNDER-STAIR SURFACE & SOFFITS SHALL BE PROTECTED ON THE ENCLOSED SIDE BY 5
8" GYPSUM BOARD.
001
XXXX
X

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022
PERMIT PLAN CHECK 03.23.2023
PERMIT SET 05.08.2023
DELTA 4 08.06.2024
DELTA 5 01.02.2025
DELTA 6 04.29.2025

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
DELTA 7 06.04.2025
190' ENTRY BENCH
BAR
5'-5" X 2'-0"

LINE OF EXISTING

GARAGE ABOVE

EXISTING

RIDGE ABOVE

EXISTING

BEAM ABOVE

ROOF ABOVE
PLANTER 5'-7" 9'-8" 4'-5
1 2
" 5'-9
1 2
" 4'-5
1 2
" 4'-5"
MASTER
CLOSET
110
POWDER
103
ENTRY
101
MASTER

BATHROOM
109
MASTER

BEDROOM
108
LIVING
ROOM
104
DINING
ROOM
105

KITCHEN
106
PANTRY
107
DECK

BUILT-IN

WINDOW SEAT
11 1
2 " 2'-3"
8'-6" 2'-6"

CANTILEVERED

BAY WINDOW

CANTILEVERED
BAY WINDOW 13'-3"
28'-6" 10'-0"
T.O. MAIN LEVEL F.F.
197'-3"
T.O. DECK F.S.
197'-1"
A500
2 A501
2 A502
2 A503
2 A600
1 BUILT-IN
DESK
UP UP
A600
2 T.O. PATIO F.S.
196'-10"
T.O. LANDING
198'-1"
T.O. LANDING
200'-7"
T.O. LANDING
203'-1"
T.O. LANDING
206'-3"

LANDING AT EXISTING GRADE
4'-0"
⅊
4'-4" S.Y.S.B.
7'-1" S.Y.S.B. 10'-0" F.Y.S.B
⅊
NEW 6'Ø PRE-FABRICATED,

FREESTANDING, SELF
CONTAINED JACUZZI. BUILT-IN

SEATING
17" HIGH STEP /
SEAT AROUND 6' Ø

JACUZZI
5'-0" A601
#
BENCH
103
110
A
110
B
109
A
108
A
108
D
108
E
108
F
108
G
105 104
A
105
B
106
F
106
E
106
D
106
C
106
B
106
A
107
101
A
108
C
108
B
101
C
DN
P1
P1
C2
C2
P2
C2
P2
C2
C2
C2
C2
C2 C2
C2
P2
C2
C2
C2
C2
C2
C1
P3 F1
P4
P5
P7
A3
A5
A6
A7
A4
A8
F2
F2
F3
F3
M1
M3
M3
M6
109
C
109
D
109
E
109
F

REFERENCE STAIR

DETAILS PLAN ON
1/A700 1'-6"
1'-6"
6'-11
1 2 5'-0 " 12
" 16'-6" 3'-7"
5'-8
1 2
" 9'-10
1 2
" 12'-5"
110
B 3'-4
1 2
" 6'-4
1 2
"
2'-7
1 2 2'-5 " 1
2 " EQ. EQ.
2'-3"
4'-11
1 2
"
2'-6
1 2
"
110
B
109
G
3'-6
1 2
" 1'-6" 3'-5
1 2 1'-6 " 1
2 "
110
B EQ. EQ.
4'-3
1 2
" EQ. EQ. EQ. EQ.
4'-0" 6'-1" 4'-8"

FUR WALL TO FLUSH WITH
SLIDING DOOR FRAME 3'-0"
24" DECK EXPANSION

EXISTING APPROVED

MAIN LEVEL NEW

WORK PLAN
A101
1 1/4" = 1'-0"

MAIN LEVEL NEW WORK PLAN
NORTH
7 7
99 ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022
PERMIT PLAN CHECK 03.23.2023
PERMIT SET 05.08.2023
DELTA 4 08.06.2024
DELTA 5 01.02.2025
DELTA 6 04.29.2025

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
DELTA 7 06.04.2025 9'-0"
T.O. GARAGE F.F.
206-3" 8'-8"
T.O. BASEMENT F.F.
188'-7"
T.O. MAIN LEVEL F.F.
197'-3" ⅊
10'-0"
F.Y.S.B.
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB
5'-0"

REDUCED
GARAGE F.Y.S.B.EXISTING HEIGHT ABOVE CURB 9'-8"
T.O. UPPER CURB
206'-0"
40'-0" 13'-0"
30' BUILDING

ENVELOPE ABOVE
EXISTING GRADE 2 5 3 3 4 4 1 4

EXISTING GRADE

EXISTING RETAINING
WALLS
FLOOR LINE BEYOND HEIGHT ABOVE GRADE EXISTING HEIGHT ABOVE GRADE 18'-2" 20'-2" EXISTING HEIGHT ABOVE CURB 9'-8" T.O. RAILING
3'-6" A.F.S. 9'-0"
T.O. GARAGE F.F.
206-3" 8'-8"
T.O. BASEMENT F.F.
188'-7"
T.O. MAIN LEVEL F.F.
197'-3"
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB ⅊
10'-0"
5'-0"

REDUCED
GARAGE F.Y.S.B.

T.O. UPPER CURB
206'-0" 13'-0"
F.Y.S.B.

T.O. ROOF
210'-6"
40'-0" 30'-0"
30' BUILDING

ENVELOPE ABOVE
EXISTING GRADE 6 7 9

EXISTING GRADE

STAIR LANDING AT

EXISTING GRADE

EXISTING RETAINING
WALLS
NEW 6'Ø PRE-FABRICATED,

FREESTANDING, SELF
CONTAINED JACUZZI.

REMOVE EXISTING

RETAINING WALLS

FLOOR LINE BEYOND
17" HIGH STEP / SEAT
AROUND 6' Ø JACUZZI
(N) 6'-0" RETAINING WALL
PER DETAIL 6/S-0.20
(N) V-DITCH FOR

DRAINAGE
10'-0" 24" DECK EXPANSION

EXISTING APPROVED

ELEVATION KEYNOTES
EXISTING ROOFING TO BE REPLACED WITH CLASS 'A' STANDING SEAM METAL ROOF.

PROVIDE GUTTERS AND DOWNSPOUTS TIED INTO EXISTING DRAINAGE SYSTEM

EXISTING ROOF TO BE REPLACED WITH NEW ENTRY ROOF

EXISTING STAIR TO BE REPLACED, REFERENCE NEW WORK PLANS

EXISTING WINDOWS / DOOR TO BE REMOVED, REFERENCE NEW WORK PLANS FOR

REVISED OPENING

EXISTING CHIMNEY TO BE REMOVED

CUT OPENING FOR NEW DOOR OR WINDOW, REFERENCE NEW WORK PLANS

NEW RAISED ROOF AT ENTRY, REFERENCE NEW WORK PLANS

PROPOSED EXTERIOR LIGHT FIXTURE, REFERENCE EXTERIOR LIGHTING PLAN FOR MORE INFORMATION. LIGHT FIXTURES MUST BE DOWN LIT OR SHIELDED TO PREVENT GLARE. TOP OF FIXTURE TO BE OPAQUE.

NEW HORIZONTAL SIDING, REFERENCE DETAILS 3-5/A800

NEW BAY WINDOW
NEW SELF CLOSING WOOD GATE WITH SELF-LATCHING MECHANISM. REFER TO SITE PLAN FOR HEIGHT 123456789
10 11

EXTERIOR

ELEVATIONS
A502 2 1/4" = 1'-0"
PROPOSED WEST ELEVATION 1 1/4" = 1'-0"
EXISTING WEST ELEVATION 7 7
100

DESIGN REVIEW BOARD STAFF REPORT
February 23, 2023
Agenda Item No. 4.3
Case No: Design Review 22-2245
Variance 22-2266
Categorical Exemption
Project Location: 31421 Holly Drive | APN: 056-061-16
Applicant: Dave Frith, Architect
(949) 376-3080 | [email protected]
Property Owner: Aina & Gordon McBean
Prepared By: Community Development Department
Kevin Parker, AICP | Associate Planner
(949) 464-6632 | [email protected]
Board Members within a
500’ Radius: None
REQUESTED ACTION: The applicant requests design review for a 760 square foot addition (first level:
351 SF; second level: 409 SF) to an existing 1,875 square foot single-family residence within the R-1 zone.

The request includes the removal of an existing chimney, a new 300 square foot second-level rear balcony, new doors/windows, a new bay window, a new above ground spa, a 340 square foot remodel that includes the conversion of a bedroom into a new master bathroom, new metal roofing, new AC unit, and replacement of siding. The applicant requests a variance to construct the proposed addition without adding an additional covered parking space or without expanding the existing, legal nonconforming 279 square foot, one-car garage into a two-car garage (LBMC Section 25.56.008(C)).

RECOMMENDATION: Adopt Resolution No. 2245, approving Case No. DR 22-2245, and VAR 22- 2266, for the development of a 760 square foot addition, and new 300 square foot rear balcony to an existing single-family residence, subject to the attached Exhibits ‘A’, ‘B’; and adopt Categorical Exemption pursuant to the California Environmental Quality Act (CEQA).

ATTACHMENTS
1) Draft Resolution
2) Exhibit ‘A’: General Plan Compliance
3) Exhibit ‘B’: Conditions of Approval
Attachment 8
101
DR-22-2245, VAR 22-2266
February 23, 2023

Page 2 ends

4) Exhibit ‘C’: Proposed Plans

PROPERTY AERIAL PHOTO

PROPERTY INFORMATION
Land Use Designation Village Low Density (1-7 DU/AC)
Zoning Designation R-1 Residential Low Density
Existing Site Improvements
• The existing single-family residence was constructed under the County’s jurisdiction in 1952. The City does not have the original building permit on file.
• 10/24/95 - reroof - permit # 95-1822
• 10/27/04 - replace retaining wall - permit # 04-2166
• 1/19/05 - replace two windows - permit # 05-107
• 7/29/05 – construct three terrace walls – permit # 05-1470 Prior Approvals • None
102
DR-22-2245, VAR 22-2266
February 23, 2023

Page 3 ends

ZONING REVIEW
The proposed project complies with applicable zoning standards and guidelines as shown in the summary table below.

Development Standard Required Existing Proposed Total Proposed Site Coverage – Lot 6,874 SF 2,612 SF (38%) 1,740 SF 409 SF 2,149 SF (31%) Height (Lowest floor to top of roof) 30’ 20.125’ 20.125’ No change Setbacks
Front (North)
Side (West)
Side (East)
Front (South)
10’

7.08’

4.33’
20’

26.92’

7.08’

4.33’
50’

23.26 7.08’

4.33’
50’
-3.66’
No change
No change
No change

PROJECT DESCRIPTION
The subject property is located in South Laguna Beach, just one block northeast of South Coast Highway, on a through lot between Holly Drive (north elevation), and Ocean View Street (south elevation), in the R-1 zone. The subject property has a 27 percent steep slope, with a high point along the north elevation.

The scope of work includes a new 760 square foot addition (first level: 351 SF; second level: 409 SF) to an existing 1,875 square foot single-family residence, the removal of an existing chimney, a new 300 square foot second-level rear balcony, new doors/windows, a new bay window, a new above ground spa, a 340 square foot internal remodel that includes the conversion of a bedroom into a new master bathroom, new metal roofing, a new AC unit, replacement of siding, and a variance for the proposed addition without meeting the required parking onsite. The applicant requests a variance to construct the proposed addition without adding an additional covered parking space or without expanding the existing, legal nonconforming, 279 square foot, one-car garage, into a two-car garage (LBMC Section 25.56.008(C)).

The portion of the proposed addition (351 SF) on the first level is within existing enclosed, uninhabitable mechanical and storage space underneath the existing second level. The portion of the proposed addition (409 SF) on the second level is within the footprint of an existing attached front patio cover, outside the front yard setback, on top of existing and previously graded flat cement, as shown in on the next page in Figure 1. Moreover, the proposed second-level balcony on the rear of the existing single-family residence, will not protrude out further than the second level balconies to the adjoining properties to the east and west of the subject property, as shown on the next page in Figure 2. 103
DR-22-2245, VAR 22-2266
February 23, 2023

Page 4 ends

Figure 1- North Elevation
Figure 2- Balcony Staking
View of adjoining property to the east. View of adjoining property to the west. 104
DR-22-2245, VAR 22-2266
February 23, 2023

Page 5 ends

DESIGN REVIEW
Pursuant to LBMC Section 25.05.040(H), physical improvements and site developments subject to design review shall be designed and located in a manner which best satisfies the intent and purpose of design review, the city’s village atmosphere and the design review criteria. These guidelines complement the zoning regulations by providing conceptual examples of potential design solutions and design interpretations. The table below lists the guidelines and the proposed project’s applicability and compliance. The following project components require Design Review:
• 760 square foot addition (first level: 351 SF; second level: 409 SF). • 300 square foot second-level rear balcony.
• 340 square foot remodel that reduces the number of bedrooms from four to three (converting an existing bedroom into the new master bathroom).
• New above ground spa.
• Removal of an existing chimney.
• New bay window.
• New AC unit.
• New metal roofing and replacement of siding.

Design Review Criteria Consistency (Yes, No, or N/A If Not Applicable) No. 1 | Access
Yes. The subject property only provides a legal non-conforming one-car garage onsite for the existing 1,875 square foot singlefamily residence. If the requested variance for additions without providing one additional on-site parking is approved, staff believes this criterion has been met as no changes would be made to the legal nonconforming condition.

No. 2 | Design Articulation
Yes. The proposed addition is within the allowable building envelope and maintains the height of the existing structure, which would not increase the massing of the structure as viewed from the street. The proposed addition does not create any
nonconforming setback issues, or open space/ landscape
percentage insufficiencies. The new entryway addition provides a new pitched roof and an architectural projection that extends out approximately 3.7 feet further than the rest of the addition along the north elevation, providing articulation and changes in plane, as shown below in Figure 3:

Figure 3- North Elevation
105
DR-22-2245, VAR 22-2266
February 23, 2023

Page 6 ends

No. 3 | Design Integrity
Yes. The proposed rear second-level balcony does not extend further towards the rear property line than the second level balconies on the adjoining properties to the east and west of the subject property. Thus, the proposed second-level balcony is not anticipated to disrupt any adjoining property viewsheds.

Furthermore, the proposed addition is within the existing footprint of a solid patio cover. The metal roofs and new siding provide a contemporary architecture style that is compatible with the surrounding community.

No. 4 | Environmental Context
Yes. The proposed project involves a small addition within the existing footprint of the residence and requires negligible grading. There are no natural features such as rock outcroppings, ridgelines or significant watercourses present. Therefore, this criterion has been met.

No. 5 | General Plan Compliance
Yes. The proposed project complies with the goals and policies of the General Plan as shown in Exhibit ‘A’
No. 6 | Historic Preservation N/A. The single-family residence constructed in 1952 has not been designated as a historical resource.

No. 7 | Landscaping
Yes. No landscaping changes are proposed as part of the proposed project. Additions are within an existing covered patio and enclosed uninhabitable storage space.

No. 8 | Lighting and Glare Yes. The proposed project is required and conditioned to comply with the City’s Good Neighbor Lighting Ordinance.

No. 9 | Neighborhood Compatibility
Yes. The proposed project will not change the property’s compatibility within the neighborhood in that it does not significantly increase the size of the existing structure and keeps a single-family residential character for the site.

No. 10 | Pedestrian Orientation N/A. This criterion pertains to commercial development.

No. 11 | Privacy
Yes. No privacy concerns have been identified. At the time of this report being written, staff has not received any comments related to privacy concerns from any neighbors.

No. 12 | Public Art N/A. This criterion pertains to commercial development.

No. 13 | Sign Quality N/A. This criterion pertains to commercial development.

No. 14 | Sustainability
Yes. New construction is required to meet Title 24 Energy and Building Code requirements, which include insulated windows and energy efficient lighting. The applicant will be required to provide proof of compliance prior to building permit issuance.

No. 15 | Swimming Pools, Spas and
Water Features
Yes. The proposed above ground spa is not located within the front, side or rear yard setbacks, and will be protected with a building code required five -foot fence and self-latching gate, to prevent the accidental entering from the nearby community.

No. 16 | View Equity
Yes. Existing views will be protected. The proposed second-level balcony is not anticipated to disrupt any adjoining property viewsheds as indicated in Figure 2. Therefore, this criterion has been met.
106
DR-22-2245, VAR 22-2266
February 23, 2023

Page 7 ends

VARIANCE
Variances may be granted only when, among other factors, there are special circumstances applicable to the property involved, including size, shape, topography, location and surroundings, that would cause the strict application of the zoning ordinance to deprive the property of the privileges enjoyed by other similarly situated property in the vicinity and zone. The following project components require Variance:

1. Construct the proposed 760 square foot addition (total square footage with proposed addition: 2,635) without adding an additional covered parking space or without expanding the existing, legal nonconforming 279 square foot, one-car garage into a two-car garage (LBMC Section

25.56.008(C)).

The Design Review Board may approve, approve in part, or conditionally approve a variance based upon making all of the following findings at a noticed public hearing:
(1) There are special circumstances applicable to the property involved, including size, shape, topography, location or surroundings which cause the strict application of the zoning ordinance to deprive such property of privileges enjoyed by other property in the vicinity and under identical zoning classification.

The subject property is located on a steep, 27 percent sloped, 6,875 square foot through lot in South Laguna Beach. This area of the City was developed under the County of Orange jurisdiction and was later annexed to the City in the late 1990’s. The existing 1,875 square foot, two-story residence, with attached 279 square foot, one-car garage, is legal non-conforming. According to LBMC (Section 25.56.008(C) Adding to or enlarging nonconforming structure) “…existing single-family dwellings that have a nonconforming number of required parking spaces may be enlarged or expanded without complying with the required number of spaces, if the total gross floor area of the residential structure, including the proposed enlargement or addition, does not exceed fifteen hundred square feet and at least one parking space is provided on the property.” The portion of the proposed addition (351 SF) on the first level is within existing enclosed, uninhabitable mechanical and storage space underneath the existing second level. The portion of the proposed addition (409 SF) on the second level is within the footprint of an existing attached front patio cover, outside the front yard setback, on top of existing and previously graded flat cement. Widening the existing onecar garage onsite, may effectively eliminate one street parking space, providing no net gain of parking. See Figure 4 below.

Figure 4- View of Subject Property from Holly Drive
107
DR-22-2245, VAR 22-2266
February 23, 2023

Page 8 ends

Additionally, the applicants only options for complying with the two covered parking spaces requirement would be to: 1) add an additional covered parking space on the high side of the lot adjacent to the existing garage; 2) construct a new two-car garage; or 3) take access from the lower portion of the lot from Ocean View Street. Options numbers 1 and 2 would require a complete redesign of the front access area. Moreover, it would add massing on the high side of the lot along Holly Drive, and potentially make the project cost prohibitive for the applicant due to the location, existing topography, and construction of the existing garage. Option number 3 would allow access from the lower portion of the lot, but would require an excessive excavation of the earth to make the necessary cuts into the steep slope. Furthermore, this proposal would not be user friendly to the applicant due to the steep terrain, and would surmount to an expensive, un-practical “checking of the box” for code compliance of parking. In staff’s analysis of the site, which included a site visit, it is staff’s belief the strict application of the zoning ordinance would be depriving the applicant the ability to construct an addition that is mostly within the existing building footprint and causing no additional massing to the site and therefore, staff believes this finding can be made. (2) Such variance is necessary for the preservation and enjoyment of a substantial property right of the applicant, which right is possessed by other property owners under like conditions in the same vicinity and zone.

The proposed 760 square foot two-story addition is modest in nature since it is not expanding the existing footprint or height of the structure. The proposed project is reducing the number of bedrooms from four to three, thus, reducing the assumed number of cars needing to be parked. While not precedent setting, a similar sized lot located one street over on 31411 Monterey Street has just a one car garage, as indicated below in Table A:

Table A- Similar Property
Address Bedrooms Building Square Footage Onsite Parking Subject Property 4 existing
3 proposed
2,635 (proposed total) 1 garage
31411 Monterey St 3 1,936 1 garage
(3) The granting of the variance will not be detrimental to the public health, safety, convenience and welfare or injurious to property or improvements in the vicinity in which the property is located.

The 760 square foot addition, will not impact any view sheds, it will maintain the existing building envelope setbacks, and height. The proposed project reduces the number of bedrooms, and therefore will not cause the need for any additional parking. The open space landscape percentage is being maintained towards the rear of the property with lush landscape. The proposed project is categorized as a minor remodel. Adding covered parking on the south end of the property along Ocean View Street will require extreme cuts into the slope, it would reduce the percentage of open space landscaping significantly, and it would trigger the project into a major remodel, subject to additional requirements and expenses. Existing slope is shown below in Figure 5:
108
DR-22-2245, VAR 22-2266
February 23, 2023

Page 9 ends

Figure 5- View from South Elevation
(4) The granting of such a variance will not be contrary to the objectives of the zoning ordinance or the general plan.

The granting of the variance will not be contrary to the objectives of the Zoning Ordinance or the General Plan as identified in Exhibit A). The addition would facilitate development that would closely mirror the single-family residences found within the nearby community. Furthermore, the project does not protrude outside the existing footprint.

ADDITIONAL INFORMATION:

California Environmental Quality Act (CEQA) Determination In accordance with the California Environmental Quality Act (CEQA) guidelines, the project is categorically exempt pursuant to Class 1, Section 15301(e)(1) - Existing Facilities, Class 31, Section 15331.

Class 1, Section 15301(e)(1) - Existing Facilities, in that the project consists of the repair, maintenance, or minor alteration of existing structures or topographical features, involving negligible or no expansion of existing or former use. Additions to existing structures provided that the addition will not result in an increase of more than 50 percent of the floor area before the addition (existing floor plan 1,875 square feet), or 2,500 square feet, whichever is less. The proposed addition is 760 square feet. 109
DRAFT DRB RESOLUTION 22-2245

A RESOLUTION OF THE OF THE DESIGN REVIEW BOARD OF THE

CITY OF LAGUNA BEACH, CALIFORNIA APPROVING DESIGN
REVIEW 22-2245, AND VARIANCE 22-2266, FOR A 760 SQUARE FOOT ADDITION, A 300 SQUARE FOOT BALCONY, A VARIANCE FOR NOT

MEETING THE REQUIRED PARKING ONSITE AND APPROVING

CATEGORICAL EXEMPTION PURSUANT TO CALIFORNIA
ENVIRONMENTAL QUALITY ACT.
31421 Holly Drive | APN: 056-061-16
WHEREAS, on January 31, 2023, a notice was mailed to all property owners within a 300' radius and tenants within a 100' radius announcing the February 23, 2023, public hearing of the Design Review Board for the proposed project; and
WHEREAS, on February 23, 2023, the Design Review Board carefully considered the oral and documentary evidence and arguments presented at the duly noticed hearing.

NOW, THEREFORE, THE DESIGN REVIEW BOARD OF THE CITY OF LAGUNA BEACH DOES HEREBY FIND, DETERMINE AND RESOLVE AS FOLLOWS:

Section 1: Design Review 22-2245, and Variance 22-2266 for a 760 square foot addition (first level: 351 SF; second level: 409 SF) to an existing 1,875 square foot single-family residence, the removal of an existing chimney, a new 300 square foot second-level rear balcony, new doors/windows, a new bay window, a new above ground spa, a 340 square foot internal remodel that includes the conversion of a bedroom into a new master bathroom, new metal roofing, a new AC unit, replacement of siding, and a variance for the proposed addition without meeting the required parking onsite (“Proposed Project”) is approved. The proposed project is exempt from the provisions of the California Environmental Quality Act in accordance with State CEQA Guidelines Section 15301 - Existing Facilities, in that the project consists of the repair, maintenance, or minor alteration of existing structures or topographical features, involving negligible or no expansion of existing or former use.; and Section 2: The proposed project is consistent with the applicable Laguna Beach Municipal Code Title 25 development standards and guidelines as outlined in the Zoning Review section of the Staff Report.

Section 3: The proposed project is consistent with the Design Review criteria related to access, design articulation, design integrity, environmental context, general plan compliance, landscaping, lighting, neighborhood compatibility, privacy, sustainability, and view equity as outlined in the Design Review section of the Staff Report.

Section 4: The Variance findings can be made for the Proposed Project for the reasons and factual basis set forth in the Variance section of the Staff Report.

Section 5: The project is in conformity with all the applicable provisions of the general plan and any applicable specific plans for the reasons and factual basis set forth in Exhibit A of the Staff Report. 110
Section 8: Terms and Conditions Run with the Land. These terms and conditions shall be perpetual, and it is the intention of the approval authority and the permittee to bind all future owners and possessors of the subject property to the terms and conditions.

Section 9: Indemnification. The permittee shall defend, hold harmless and indemnify, at his/her/its expense, the City, the City Council and other City bodies and members thereof, officials, officers, employees, agents and representatives (collectively, the City) from and against any and all third-party claims, actions or proceedings to attack, set aside, void or annul the approval of this application for Design ReviewDesign Review, or any associated determination made pursuant to the California Environmental Quality Act. This obligation shall encompass all costs and expenses incurred by the City in defending against any claim, action or proceeding, as well as costs, expenses or damages the City may pay as a result of such claim, action or proceeding. In the event an action or proceeding is filed in court against the City, the Design Review, or any associated determination, the permittee shall promptly be required to execute a formal indemnification agreement with the City, in a form approved by the City Attorney, which shall include, among other things, that the City will be defended by the counsel of its choice, and that the permittee shall deposit with the City sufficient funding, and thereafter replenish the funding, to ensure that the City’s defense is fully funded, by the permittee. The deposit amount and replenishment schedule shall be established by the City.

Section 10: Plan Reliance and Modification Restriction. In the absence of specific provisions or conditions herein to the contrary, the attached Staff Report and its Exhibits ‘A’, and ‘B’, are incorporated and made a part of this Resolution. It is required that the Exhibits ‘B’ be complied with and implemented in a manner consistent with the approved use and other conditions of approval. Such exhibits for which this permit has been granted shall not be changed or amended except pursuant to a subsequent amendment to the permit or new permit as might otherwise be required or granted pursuant to the terms of Title 25 of the Laguna Beach Municipal Code.

Section 11: Grounds for Revocation or Modification. Failure to abide by and faithfully comply with Exhibits ‘B’ and ‘C’ attached to the granting of the proposed project may constitute grounds for revocation or modification of the permit.

Section 12: Right of Appeal and Effective Date. The applicant or any other owner of property within three hundred feet of the subject property aggrieved by the Design Review Board’s decision on Design Review 22-1451 or Variance 22-1928 may appeal such decision to the City Council. The Design Review Board’s determination to approve a Categorical Exemption under CEQA may be appealed by any person to the City Council. Any appeal shall be in written form filed with the City Clerk within fourteen calendar days of the decision and shall specifically state each and every ground for the appeal and be accompanied by payment of the required appeal fee. If no appeal is filed timely, the Design Review Board decision will be effective 14 calendar days after the date of the decision.

Section 13: For the foregoing reasons and based on the information and findings included in the Staff Report, Minutes and records of proceedings, the Design Review Board of the City of Laguna Beach hereby approves the proposed project, subject to the conditions of approval and plans in the attached Exhibits ‘B’.
111
PASSED on February 23, 2023, by the following vote:

AYES:

NOES:

ABSENT:

ABSTAIN:

ATTEST: ______________________________________
Don SheridanDon Sheridan, Chair
Russell W. Bunim, AICP, Planning Manager
112
EXHIBIT ‘A’

GENERAL PLAN GOALS AND POLICIES CONFORM (Y, N OR N/A)
Land Use Element (LU) Policy 2.10 Maximize the
preservation of coastal and canyon views (consistent
with the principle of view equity) from existing
properties and minimize blockage of existing public
and private views.

Yes, refer to Design Review Criterion No. 16 above.

LU Element Action 7.3.2 Review all applications
for new development to determine potential threats
from coastal and other hazards.

LU Element Action 7.3.3 Design and site new
development to avoid hazardous areas and minimize
risks to life and property from coastal and other
hazards.

N/A. this project is not located on an oceanfront
blufftop lot.

LU Element Action 7.3.4 Require new
development to assure stability and structural
integrity, and neither create nor contribute
significantly to erosion, geologic stability, or
destruction of the site or surrounding area or in any
way require the construction of protective devices
that would substantially alter natural landforms
along bluffs and cliffs.

Yes, the development will not create nor contribute
significantly to erosion, geologic stability, or
destruction of the site or surrounding area and will
not require construction of protective devices.

LU Element Action 7.3.5 Prohibit development on
oceanfront bluff faces, except public improvements
providing public access, protecting coastal
resources, or providing for public safety. Permit
such improvements only when no feasible
alternative exists and when designed and
constructed to minimize landform alteration of the
oceanfront bluff face, to not contribute to further
erosion of the oceanfront bluff face, and to be
visually compatible with the surrounding area to the
maximum extent feasible.

N/A, this project is not located on an oceanfront
blufftop lot.

LU Element Action 7.3.6 Require new
development on oceanfront blufftop lots to
incorporate drainage improvements, removal of
and/or revisions to irrigation systems, and/or use of
native or drought-tolerant vegetation into the design
to minimize threats to oceanfront bluff recession.

N/A, this project is not located on an oceanfront
blufftop lot.

LU Element Action 7.3.8 On oceanfront bluff sites,
require applications where applicable, to identify
and removal all unpermitted and/or obsolete
structures, including but not limited to protective
devices, fences, walkways, and stairways, which
encroach into oceanfront bluffs.

N/A, this project is not located on an oceanfront
blufftop lot.
113

GENERAL PLAN GOALS AND POLICIES CONFORM (Y, N OR N/A)
LU Element Action 7.3.9 Ensure that new
development, major remodels and additions to
existing structures on oceanfront and oceanfront
bluff sites do not rely on existing or future
bluff/shoreline protection devices to establish
geologic stability or protection from coastal hazards.

N/A, this project is not located on an oceanfront
blufftop lot.

LU Element Action 7.3.10 Allow oceanfront and
oceanfront bluff homes, commercial structures, or
other principal structures, that are legally
nonconforming as to the oceanfront and/or
oceanfront bluff edge setback, to be maintained and
repaired; however, improvements that increase the
size or degree of nonconformity, including but not
limited to development that is classified as a major
remodel pursuant to the definition in the Land Use
Element Glossary, shall constitute new development
and cause the pre-existing nonconforming
oceanfront or oceanfront bluff structure to be
brought into conformity with the LCP.

N/A, this project is not located on an oceanfront
blufftop lot.

LU Element Action 7.3.11 Require all coastal
development permit applications for new
development on an oceanfront or on an oceanfront
bluff property subject to wave action to assess the
potential for flooding or damage from waves, storm
surge, or seiches, through a wave uprush and impact
report prepared by a licensed civil engineer with
expertise in coastal processes. The conditions that
shall be considered in a wave uprush study are: a
seasonally eroded beach combined with long-term
(75 years) erosion; high tide conditions, combined
with long-term (75 year) projections for sea level
rise; storm waves from a 100-year event or a storm
that compares to the 1982/83 El Niño event.

N/A, this project is not located on an oceanfront
blufftop lot.

OSC Policy 1.5Q Any development application for
shoreline construction shall be reviewed with
respect to the criteria contained in the Guidelines for Shoreline Protection, including the effects of beach
encroachment, wave reflection, reduction in seacliff
sand contribution, end effects and aesthetic criteria.

N/A, this project is not located on an oceanfront
blufftop lot.
114
EXHIBIT ‘B’

CONDITIONS OF APPROVAL
Standard Conditions:

1. The conditions of approval shall be and hereby are obligations of and binding upon the applicant and his/her heirs, successors, assigns, agents and representatives. The conditions shall constitute a covenant running with and binding the land in accordance with the provisions of California Civil Code Section 1468. Failure to comply with such conditions, and each of them, and any other related federal, state and local regulations may be grounds for revocation of the approval, in addition to other remedies that may be available to the City.

2. The applicable Certificate of Use and/or Certificate of Occupancy shall not be issued until City staff has verified compliance with all conditions of approval.

3. Prior to Building Permit issuance, the owner, his architect/designer/structural engineer, and contractor of the subject property shall sign an Affidavit of Plan Consistency, whereby the signees affirm that the structural plans are consistent with the Zoning Division-approved set of plans and any modification will require subsequent review and approval.

4. In the absence of specific provisions or conditions herein to the contrary, the application and all relevant plans and exhibits are incorporated and made a part of this approval. It is required that such plans and exhibits be complied with and implemented in a consistent manner with the approved use and other conditions of approval. Such plans and exhibits for which this approval has been granted shall not be substantially changed or substantially amended except pursuant to a subsequent approval as might otherwise be required or granted pursuant to the terms of Title 25 of the City of Laguna Beach Municipal Code.

5. The permittee shall defend, hold harmless and indemnify, at his/her/its expense, the City, the City Council and other City bodies and members thereof, officials, officers, employees, agents and representatives (collectively, the City) from and against any and all third-party claims, actions or proceedings to attack, set aside, void or annul this approval, or any associated determination made pursuant to the California Environmental Quality Act. This obligation shall encompass all costs and expenses incurred by the City in defending against any claim, action or proceeding, as well as costs, expenses or damages the City may be required by a court to pay as a result of such claim, action or proceeding.

6. Expiration. This approval shall lapse and become void two years following the effective date if the privileges authorized by design review are not executed or utilized or, if construction work is involved, such work is not commenced within such two-year period and diligently pursued to completion. The approval authority may grant a two-year extension of time and, after that initial extension of time, a final one-year extension of time. Such time extensions shall be requested in writing by the applicant or authorized agent prior to the expiration of the beginning two-year approval period or a subsequently approved extension of time. 115

7. Reapplication Waiting Period. After denial of a project, no application for a project located on the same parcel or building site may be filed or accepted for filing for two months.

8. Light trespass that results in glare is prohibited.

9. Outdoor lighting must be hooded, fully shielded, and aimed downward.

10. Modifications. Additions or enlargements of structures upon property for which a variance has been granted shall not be allowed except pursuant to a subsequent variance as might otherwise be required or granted pursuant to the terms of Title 25 of the City of Laguna Beach Municipal Code.

Project Specific Special Conditions:

1. The five-foot fence proposed along Holly Drive shall be constructed according to the 2022 California Building Code requirements for a non-climbable fence that secures a swimming pool/spa, and include the self-latching requirements for the front access gate. 116
EXHIBIT ‘C’

PROPOSED PLANS
117

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110

SPRINKLER DETERMINATION
31421 HOLLY DR

EXISTING AREA VALUE PER SF VALUATION
HABITABLE AREA 1,875 S.F. 225.30 422,437.50
GARAGE 279 S.F. 89.26 24,903.54
DECKS 0 89.26 0.00
MECHANICAL / STORAGE 351 S.F. 89.26 31,330.26
TOTAL 478,671.30

PROPOSED AREA VALUE PER SF VALUATION
HABITABLE AREA ADDITION 760 S.F. 225.30 171,228.00
HABITABLE AREA REMODEL 340 S.F. 180.24 61,281.60
GARAGE 0 S.F. 89.26 0.00
DECKS 300 S.F. 89.26 26,778.00
MECHANICAL / STORAGE -351 S.F. 89.26 -31,330.26
TOTAL 227,957.34
RATIO= 48% COMPARED WITH 50%

SPRINKLERS NOT REQUIRED

ARCHITECT

BEACH BUS STUDIOS
349 THIRD STREET
LAGUNA BEACH, CA 92651
(949) 376-3080
CONTACT: DAVE FRITH
[email protected]

STRUCTURAL ENGINEER
CORE STRUCTURE, INC.
23172 PLAZA POINTE DR., SUITE 145
LAGUNA HILLS, CA 92653
(949) 954-7244
CONTACT: AMIR DEIHIMI
[email protected]
TITLE 24 ENERGY CONSULTANT

CARSTAIRS ENERGY CALCULATIONS
2238 BAYVIEW HEIGHTS DR, SUITE E
LOS OSOS, CA 93402
(805) 904-9048
CONTACT: TIMOTHY CARSTAIRS
[email protected]

PROJECT CONSULTANTS

PROJECT ADDRESS
31421 HOLLY DR
LAGUNA BEACH, CA 92651
OWNERS

AINA & GORDON MCBEAN
(949) 376-3080
LEGAL DESCRIPTION N TR 713 BLK LOT 205
ASSESSOR PARCEL NO. (APN) 056-061-16
PARCEL ID NO. (PIN) 1036

COUNTY OF ORANGE
ZONE DISTRICT R1

CONSTRUCTION TYPE V-B

BUILDING DOES NOT HAVE A FIRE SPRINKLER SYSTEM

PROJECT INFORMATION

SUMMARY OF EXTERIOR ARCHITECTURAL IMPROVEMENTS

1. ENCLOSE OUTDOOR PATIO, CONVERT TO HABITABLE AREA

2. MAIN LEVEL DECK ADDITION

3. THREE BAY WINDOWS

4. REPLACE AT GRADE EXTERIOR STAIR AT SIDE YARD AND ENTRY

5. NEW STANDING SEAM METAL ROOF TO REPLACE EXISTING

6. NEW HORIZONTAL SIDING

7. NEW DOORS AND WINDOW TO REPLACE EXISTING

8. NEW ROOF AT EXISTING ENTRYWAY

9. NEW NEW 6'Ø PRE-FABRICATED, FREESTANDING, SELF CONTAINED JACUZZI.

10. NEW AC COMPRESSOR

SUMMARY OF INTERIOR ARCHITECTURAL IMPROVEMENTS

11. KITCHEN AND BATHROOM REMODEL

SCOPE OF WORK

PROJECT SUMMARY TABLES
USE SFR ZONE R1 LOT SLOPE (%) 27%

ZONING STANDARDS

DESCRIPTION REQUIRED EXISTING PROPOSED CONFORMS
LOT AREA 6,000 S.F. 6,874 S.F. NO CHANGE YES
LOT WIDTH 70'-0" 54'-5" NO CHANGE NO
LOT DEPTH 80'-0" 126'-2" NO CHANGE YES
MAX BUILDING HEIGHT 30'-0" 20'-2" NO CHANGE YES
MAX HEIGHT FROM CURB 15'-0" 9'-8" NO CHANGE YES
SETBACKS:

FRONT YARD
5'-0" GARAGE
10'-0" HOUSE
7'-1" GARAGE
26'-11" HOUSE NO CHANGE YES
REAR YARD 20'-0" 50'-0" NO CHANGE YES
SIDE YARDS (E) 54.22' FRONT + 60' REAR = 114.22'
/ 2 = 57.11' AVERAGE WIDTH
* 20%=11.42' TOTAL S.Y.S.B. (11'-5")
4'-4" (4'-9" EXISTING) NO CHANGE YES
SIDE YARDS (W) 7'-1" NO CHANGE YES

LOT COVERAGE
(BSC)
BSC %: 35 + (8000-6874) x 9
/ 4000 = 38%
2,124 S.F. 2,149 S.F. YES 31% 31%

LANDSCAPE OPEN SPACE
1,532 S.F. 4,316 S.F. 4,037 S.F. YES 22% MIN. 63% 59%
PARKING 2 COVERED SPACES 1 COVERED NO CHANGE NO

PROJECT DATA

DESCRIPTION EXISTING PROPOSED TOTAL REMODEL
LIVING AREA:

BASEMENT 602 S.F. 351 S.F. 953 S.F. 140 S.F.

MAIN LEVEL 1,273 S.F. 409 S.F. 1,682 S.F. 200 S.F.

TOTAL 1,875 S.F. 760 S.F. 2,635 S.F. 340 S.F.

GARAGE 279 S.F. NO CHANGE 279 S.F.

ELEVATED DECK 0 S.F. 300 S.F. 300 S.F.

MECHANICAL / STORAGE 351 S.F. -351 S.F. 0 S.F.

EXISTING REMOVED REMAINING DEMO TOTAL
FLOOR AREA:

BASEMENT 602 S.F. 0 S.F. 602 S.F. 0%
MAIN LEVEL 1,273 S.F. 0 S.F. 1,273 S.F. 0%
ROOF AREA 2,124 S.F. 374 S.F. 1,750 S.F. 18%
TOTAL EXTERIOR WALL 387'-9" L.F. 110'-3" L.F. 277'-6" L.F. 28% TOTAL WALL + ROOF 46%

SITE WORK

GRADING (CUBIC YARDS) OUTSIDE BUILDING

FOOTPRINT

INSIDE BUILDING

FOOTPRINT
TOTAL
CUT 0 CUBIC YARDS 0 CUBIC YARDS 0 CU. YD.

FILL 0 CUBIC YARDS 0 CUBIC YARDS 0 CU. YD.

NET EXPORT 0 CUBIC YARDS 0 CUBIC YARDS 0 CU. YD.

IMPERVIOUS SURFACES
LOT AREA % OF LOT AREA

EXISTING PROPOSED EXISTING PROPOSED
STRUCTURE 2,124 S.F. 2,149 S.F. 31% 31%

HARDSCAPE
(INCL. DRIVEWAY) 430 S.F. 702 S.F. 6% 10%
TOTAL 2,554 S.F. 2,851 S.F. 37% 41%

EXTERIOR BUILDING LIGHTING
EXISTING EGRESS DOORS 3 PROPOSED EGRESS DOORS 6
EXISTING FIXTURE COUNT 3 PROPOSED FIXTURE COUNT 15

FIXTURE TYPE WATTAGE LUMUNES QUANTITY COMMENTS
RECESSED STAIR LIGHT 0 365 10
WALL SCONCE 3 365 4
RECESSED SOFFIT LIGHT 0 365 1
TOTAL 15

LANDSCAPE LIGHTING
EXISTING FIXTURE COUNT 10 PROPOSED FIXTURE COUNT 10

FIXTURE TYPE WATTAGE LUMUNES QUANTITY COMMENTS
GARDEN LIGHT 10 365 10
TOTAL 10
COMBINED TOTAL 25

COVER SHEET
1 NORTH
31421 HOLLY DR
LAGUNA BEACH, CA 92651

GENERAL NOTES

1. ALL CONSTRUCTION SHALL COMPLY WITH, BUT SHALL NOT BE LIMITED TO THE LATEST EDITION AND ORDINANCES OF:
2019 CALIFORNIA BUILDING CODE (CBC)
2019 CALIFORNIA RESIDENTIAL CODE (CRC)
2019 CALIFORNIA MECHANICAL CODE (CMC)
2019 CALIFORNIA PLUMBING CODE (CPC)
2019 CALIFORNIA ELECTRICAL CODE (CEC)
2019 CALIFORNIA GREEN BUILDING STANDARDS CODE (CGBS)
2019 CALIFORNIA ENERGY EFFICIENCY STANDARDS (CEES)
2019 CALIFORNIA FIRE CODE

CITY OF LAGUNA BEACH REGULATION AND ORDINANCES

2. A STAMPED SET OF APPROVED PLANS SHALL BE KEPT AT THE JOB SITE AT ALL TIMES.

3. THE CONTRACTOR SHALL VISIT THE JOB SITE AND VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO THE START OF CONSTRUCTION.

4. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO

THE ATTENTION OF THE ARCHITECT AND THE OWNER PRIOR TO PROCEEDING WITH THE WORK THE

CONTRACTOR IS RESPONSIBLE FOR CORRECTING ANY ERRORS AFTER THE START OF CONSTRUCTION WHICH IS NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT.

5. THE CONTRACTOR IS RESP0NSIBLE FOR PROTECTING ANY ON-SITE UTILITIES FROM DAMAGE DURING THE COURSE OF CONSTRUCTION.

6. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.

7. THE CONTRACTOR SHALL PROVIDE ALL NECESSARY PERMITS AND INSPECTIONS, OTHER THAN PLAN CHECK AND BUILDING PERMIT FEES PROVIDED BY THE OWNER.

8. THE CONTRACTOR SHALL PROVIDE ALL MATERIALS, LABOR, EQUIPMENT, TRANSPORTATION AND

SERVICES NECESSARY FOR SUCCESSFUL COMPLETION OF THE WORK ALL EQUIPMENT, WORK AND MATERIALS SHALL COMPLY WITH ALL APPLICABLE CODES AND GOVERNING AGENCIES.

9. THE CONTRACTOR SHALL MAINTAIN LIABILITY INSURANCE TO PROTECT HIMSELF AND HOLD THE

ARCHITECT AND OWNER HARMLESS FROM ANY AND ALL CLAIMS FOR DAMAGES FOR PERSONAL, BODILY INJURY, DEATH OR PROPERTY DURING THE COURSE OF THE CONTRACT. FIRE INSURANCE SHALL BE MAINTAINED BY THE OWNER.

10. TEMPORARY POWER AND WATER, WORKERS' TOILET FACILITIES, PARKING AND MATERIAL STORAGE SHALL BE PROVIDED BY THE CONTRACTOR.

11. THE CONTRACTOR SHALL PROTECT ALL FINISHED WORK AND ADJACENT SURFACES FROM DAMAGE

DURING THE COURSE OF CONSTRUCTION AND SHALL REPLACE AND/OR REPAIR ANY AND ALL DAMAGE CAUSED BY THE WORKERS.

12. ALL CONSTRUCTION WASTE & DEBRIS MUST BE CONTAINERIZED AT ALL TIMES. UPON COMPLETION

OF THE WORK, ALL AREAS SHALL BE LEFT BROOM CLEAN AND ALL DEBRIS SHALL BE REMOVED FROM THE SITE.

13. RECESSED BOXES, EQUIPMENT, CABINETS AND THE LIKE, 8" X 8" OR LARGER, IN "1 - HOUR RATED WALLS", SHALL MAINTAIN A 1-HOUR CONSTRUCTION RATING.

14. DIMENSIONS SHOWN ON FLOOR PLANS, SECTIONS AND DETAILS ARE TO FACE OF STUDS, CENTERLINE OF COLUMN, FACE OF MASONRY, FACE OF CONCRETE UNLESS NOTED OTHERWISE.

15. DOOR LOCATIONS NOT ESTABLISHED BY DIMENSIONS SHALL BE CENTERED IN WALL OR BE LOCATED 4 1/2" FROM ADJACENT WALL TO ALLOW FOR DOOR CASING.

16. ANY DRILLING OR NOTCHING OF STUDS FOR ELECTRICAL WIRING, UTILITY LINES, BRACING ETC.

SHALL CONFORM TO LOCAL CODE.

17. ALL GUARDRAILS SHALL BE A MINIMUM OF 42" HIGH. INTERMEDIATE MEMBERS SHALL NOT ALLOW A 4" DIAMETER OBJECT TO PASS THROUGH.

18. PROVIDE A MINIMUM STUD SIZE OF 2 X 6 WHERE USING 2" PLUMBING FIXTURES.

19. PROVIDE FULLY TEMPERED IMPACT GLAZING AT SHOWER/TUB ENCLOSURES AND AT WINDOWS ADJACENT TO BATHTUBS.

20. ALL NEW GLAZING SHALL COMPLY WITH STANDARDS OF THE U.S. CONSUMER PRODUCT SAFETY COMMISSION. MANUFACTURER TO SUPPLY CERTIFICATE OF COMPLIANCE TO THE OWNER.

21. ALL TOILETS SHALL BE "ULTRA FLUSH" TYPE AS REQUIRED BY STATE. ALL SHOWER HEADS AND LAVATORY FAUCETS TO BE LOW FLOW.

22. GARAGE DOOR SPRINGS TO BE STATE APPROVED WITH BREAK RETAINERS AND MANUFACTURERS LABELS.

23. WHERE LANDSCAPE IRRIGATION LINES ARE INSTALLED, ONLY LOS ANGELES COUNTY HEALTH DEPARTMENT APPROVED BACKFLOW PREVENTION DEVICES MAY BE UTILIZED.

24. ALL INTERIOR FINISH MATERIALS SHALL MEET CLASS III FLAME SPREAD CLASSIFICATION, PER LOCAL CODE.

25. NAILING INSPECTION IS REQUIRED FOR ALL DRYWALL AND LATH AFTER INSTALLATION BEFORE TAPING AND FINISHING. CORNER BEADS TO BE NAILED. DRYWALL BOARD SPACING TO BE 3/8" MAXIMUM.

26. THE CONSTRUCTION SHALL NOT RESTRICT A FIVE-FOOT CLEAR AND UNOBSTRUCTED ACCESS TO

WATER OR POWER DISTRIBUTION FACILITIES (POWER POLES, PULL-BOXES,TRANSFORMERS, VAULTS, PUMPS, VALVES, METERS, APPURTENANCES, ETC.) OR TO THE LOCATION OF THE HOOK-UP. THE

CONSTRUCTION SHALL NOT BE WITHIN TEN FEET FROM ANY POWER LINES - WHETHER OR NOT THE LINES ARE LOCATED ON THE PROPERTY. FAILURE TO COMPLY MAY CAUSE CONSTRUCTION DELAYS AND/OR ADDITIONAL EXPENSES.

27. EQ EMERGENCY GAS SHUT OFF VALVES TO BE INSTALLED ON ALL GAS FUEL LINES.

28. THE ARCHITECT SHALL BE PROVIDED A KEY OR COMBINATION TO THE LOCK ON JOB SITE GATES FOR ACCESS TO THE CONSTRUCTION SITE AT ALL TIMES.

29. MECHANICAL SUBCONTRACTOR TO PROVIDE THE ARCHITECT WITH A SCHEMATIC LAYOUT FOR ALL

MECHANICAL UNITS, DUCT RUNS, AND REGISTER LOCATIONS AND SIZES FOR REVIEW AND APPROVAL PRIOR TO ANY MECHANICAL ROUGH IN.

30. PROVIDE STRUCTURAL OBSERVATION PER CITY OF LOS ANGELES REQUIREMENTS.

31. DRAFT STOPPING (AT 10' INTERVALS HORIZONTAL AND VERTICAL SHALL BE PROVIDED WITHIN A

CONCEALED FLOOR/CEILIING ASSEMBLY FORMED OF COMBUSTIBLE CONSTRUCTION, ATTICS,

MANSARDS, OVERHANGS, OPENINGS AROUND VENTS, PIPES, DUCTS, CHIMNEYS, BETWEEN ATTIC AND

CHIMNEY CHASE, AT STAIR STRINGERS, AND SIMILAR CONCEALED SPACES FORMED OF COMBUSTIBLE CONSTRUCTION PER LOCAL CODE.

32. ENCLOSED USEABLE SPACE UNDER INTERIOR STAIRS REQUIRES 1-HOUR FIRE RESISTIVE CONSTRUCTION ON THE ENCLOSED SIDE PER LOCAL CODE.

33. THERE SHALL BE NO TRENCHES OR EXCAVATIONS 5 FEET OR MORE IN DEPTH INTO WHICH A PERSON IS REQUIRED TO DESCEND; OR OBTAIN A NECESSARY PERMIT FROM STATE OF CALIFORNIA, DIVISION OF OCCUPATIONAL SAFETY & HEALTH (CAL/OSHA, 714-558-4451). THIS PERMIT AND ANY OTHER SAFETY PERMIT SHALL BE OBTAINED PRIOR TO COMMENCE OF ANY WORK.

34. IT IS THE CONTRACTOR OR OWNER RESPONSIBILITY TO PROVIDE ONE HARD SET OF PLANS WITH THE COUNTY APPROVAL STAMP IN THE FIELD FOR THE INSPECTOR TO VIEW.

VICINITY MAP REFERENCE ONLY

MCBEAN RESIDENCE
31421 HOLLY DR, LAGUNA BEACH, CA 92651

SHEET INDEX
1 COVER SHEET
2 SITE PLANS
3 FIRE DEPARTMENT SITE ACCESS PLAN
4 SURVEY / STAKING PLAN
5 EXTERIOR LIGHTING PLANS
6 NOT USED
7 BUILDING SITE COVERAGE CALCULATION
8 EXISTING AREA CALCULATIONS
9 PROPOSED AREA CALCULATIONS
10 DEMOLITION PLANS
11 NEW WORK PLANS
12 ROOF PLANS
13 EXTERIOR ELEVATIONS
14 EXTERIOR ELEVATIONS
15 EXTERIOR ELEVATIONS
16 EXTERIOR ELEVATIONS
17 BUILDING SECTIONS
118

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
190'
180'
170'
200'
1 2:12
1:12
1:12 126'-2" LOT DEPTH
31421 HOLLY DRIVE
4'-4"
7'-1"
S.Y.S.B.

S.Y.S.B.
7'-1" 5'-1"
7'-4"
4'-9"
20'-0" R.Y.S.B. 7'-1" 26'-11"
TERRACED LANDSCAPE AREA 50'-0" 73'-0"
1 2:12
31441 HOLLY DRIVE
31411 HOLLY DRIVE
℄ HOLLY DRIVE
℄ OCEAN VIEW STREET

EXISTING AREA OF

ROOF TO BE

DEMOLISHED

SHOWN DASHED

EXISTING CHIMNEY

TO BE REMOVED

54.22' 139.52'
60' 113.81' 17'-6"
17'-6"

EXISTING STAIRS

AND GATE TO BE

REPLACED

EXISTING STAIRS

TO BE REPLACED

EXISTING TERRACED

LANDSCAPE WALLS TO BE
CUTBACK FOR NEW STAIR 10'-0" F.Y.S.B. 5'-0" REDUCED GARAGE F.Y.S.B. 10'-0" F.Y.S.B.

EXISTING

STONE PATH

EXISTING

RETAINING WALL

EXISTING

RETAINING WALL

EXISTING

RETAINING WALL
T.O. EXISTING
WALL = 208'-6"
T.O. EXISTING
WALL = 202'-6"
T.O. EXISTING
CURB = 206'-0"
T.O. EXISTING
WALL = 199'-6"
T.O. EXISTING
WALL = 204'-0"
T.O. MAIN LEVEL F.F.
197'-3"
T.O. BASEMENT F.F.
188'-7"
T.O. GARAGE F.F.
206-3"
T.O. EXISTING
WALL = 201'-0" T.O. PATIO F.S.
196'-10"

EXISTING CHIMNEY

TO BE REMOVED
54'-5" LOT WIDTH 139'-0
1 2
"
190'
180'
170'
200'
x x x x x x
1'-0"
13'-2" 19'-5" 10'-0" F.Y.S.B. 73'-0" 50'-0" 26'-11"
4'-9"
7'-4"
7'-1" 5'-1"
S.Y.S.B.

S.Y.S.B.
7'-1"
4'-4" 126'-2" LOT DEPTH

CANTILEVERED
BAY WINDOW 113.81'
60' 139.52'

54.22'
NEW 5' HIGH WOOD

FENCE AND GATE

NEW AT GRADE
STAIR
NEW 6'-0" HIGH

WOOD FENCE

1. GENERAL CONTRACTOR TO VERIFY AND REVIEW

EXISTING SITE DRAINAGE REQUIREMENTS WITH

ARCHITECT TO DETERMINE IF THE SYSTEM
PROVIDES ADEQUATE SITE DRAINAGE.

2. OBTAIN A SEPARATE PERMIT FOR RETAINING
WALLS, GRADING, AND SHORING (IF REQUIRED).

3. VERIFY EXACT HARDSCAPE AND PLANT MATERIAL

LAYOUTS, MATERIALS AND SPECIFICATIONS WITH
THE ARCHITECT AND LANDSCAPE ARCHITECT.

4. SUBMIT ACTUAL SAMPLES OF ALL FINISH

MATERIALS TO THE OWNER AND ARCHITECT FOR

REVIEW AND APPROVAL PRIOR TO PURCHASE AND
INSTALLATION.

5. FIELD VERIFY WITH ARCHITECT ALL SITE POWER
AND FINISHED SITE LIGHTING LOCATIONS.

GENERAL NOTES
℄ OCEAN VIEW STREET
31411 HOLLY DRIVE
31441 HOLLY DRIVE
℄ HOLLY DRIVE 3:12 3:12

TERRACED LANDSCAPE AREA
31421 HOLLY DRIVE
1:12
1:12
1 2:12

BUILDING SETBACK

SITE WALL
FENCE

PROPERTY LINE

SITE PLAN LEGEND
20'-0" R.Y.S.B. 7'-1" 17'-6"
17'-6"
TRASH
STORAGE 5'-6"
NEW AC PRO ALLIED #4AC16L36P-50A
14 SEER CONDENSING UNIT. AC UNIT
TO MAINTAIN A 5-FOOT CLEARANCE
FROM ALL PROPERTY LINES.

MAXIMUM DECIBEL LEVEL TO BE 60
DB DURING THE DAY AND 50 DB AT
NIGHT. PROVIDE SOUND

ATTENUATION AND SHOCK
ABSORBENT BASE AS REQUIRED.

AC UNIT NOISE ANALYSIS
SOUND RATING OF EQUIPMENT 76 dB
+ EQUIPMENT LOCATION FACTOR <3 dB>
- BARRIER SHIELDING FACTOR <--->
- DISTANCE FACTOR <23.5>
- SOUND ATTENUATION REDUCTION <6dB>
TOTAL 76-26.5 = 49.5 dB (COMPLIES WITH CITY OF LB REQ.) 5'-0" REDUCED GARAGE F.Y.S.B. 17 A
17 B
REFERENCE SHEET 14

DETAIL 'C' FOR SOUND

ATTENUATION TECHNIQUES
REFERENCE SHEET 14

DETAIL 'D' FOR

MANUFACTURER'S

SPECIFICATION SHEET
7'-3"
PARKING SPACE #1
8'-8"x18'-0"

EXISTING

STONE PATH

EXISTING

RETAINING WALL
T.O. EXISTING
WALL = 188'-3"
T.O. EXISTING
WALL = 185'-6" 13'-7"
20'-0"

NEW AT GRADE
STAIR
NEW 4' HIGH WOOD

FENCE AND GATE
T.O. MAIN LEVEL F.F.
197'-3"
T.O. BASEMENT F.F.
188'-7"
T.O. GARAGE F.F.
206-3"
T.O. EXISTING
WALL = 208'-6"
T.O. EXISTING
WALL = 202'-6"
T.O. EXISTING
CURB = 206'-0"
T.O. EXISTING
WALL = 204'-0"
T.O. EXISTING
WALL = 201'-0"
4'-0"
T.O. PATIO F.S.
196'-10" 6"
PROVIDE 5' HIGH WOOD POOL SECURITY
FENCING PER LBMC 25.50.016 AND LBMC

25.50.012 (A). THE FENCE SHALL HAVE

SELF-CLOSING GATES AT LEAST FIVE FEET
HIGH WITH SELF-LATCHING MECHANISM.

LATCHES SHALL BE INSTALLED AT LEAST
FOUR FEET ABOVE GROUND LEVEL.

NEW 6'Ø PRE-FABRICATED,

FREESTANDING, SELF CONTAINED
JACUZZI. JACUZZI TO BE COVERED

WITH LOCKABLE COVER WHEN NOT
IN USE. AN AUTOMATIC FILL DEVICE
IS NOT TO BE USED.
17" HIGH STEP / SEAT
AROUND 6' Ø JACUZZI
5'-0"
54'-5" LOT WIDTH 139'-0
1 2
"

SITE PLANS
2 1 1/8" = 1'-0"

EXISTING SITE PLAN
NORTH
2 1/8" = 1'-0"

PROPOSED SITE PLAN
NORTH
119

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110

DIMENSIONS SHOWN ARE

AS THE HOSE WOULD
LAY ON THE SLOPE, TYP.

ALL STAIRS TO BE

NON-COMBUSTIBLE

CONSTRUCTION, AND BUILT

IN COMPLIANCE WITH CBC
CHAPTER 10 REQUIREMENTS
ALL WEATHER 3' WIDE ACCESS

PATH, FIRE DEPARTMENT ACCESS

AREAS WITHOUT STAIRS
(INCLUDING REAR YARD) TO NOT
HAVE A SLOPE EXCEEDING 10%.
150' HOSE PULL FROM POINT B
(MEASURED AS THE HOSE LAYS)
150' HOSE PULL FROM POINT A
(MEASURED AS THE HOSE LAYS)

EXISTING FIRE HYDRANT
31421 HOLLY DRIVE
℄ HOLLY DRIVE 19'-2" 10'-0"
8'-3" 7'-10"
7'-8" 4'-0"
27'-8" 41'-5"
45'-0" 72'-4" 10'-0" 62'-4" FURTHEST POINT OF BUILDING FROM APPARATUS ACCESS ROAD UNOBSTRUCTED VERTICAL CLEARANCE OF 13'-6" FIRE ACCESS ROADWAY 20'-0" UNOBSTRUCTED ROADWAY WIDTH

POINT A POINT B
℄ OCEAN VIEW STREET

SPRINKLER DETERMINATION

PROJECT ADDRESS
31421 HOLLY DR
LAGUNA BEACH, CA 92651
OWNERS

AINA & GORDON MCBEAN
(949) 376-3080
LEGAL DESCRIPTION N TR 713 BLK LOT 205
ASSESSOR PARCEL NO. (APN) 056-061-16
PARCEL ID NO. (PIN) 1036

COUNTY OF ORANGE
ZONE DISTRICT R1

CONSTRUCTION TYPE V-B

BUILDING DOES NOT HAVE A FIRE SPRINKLER SYSTEM

PROJECT INFORMATION

SUMMARY OF EXTERIOR ARCHITECTURAL IMPROVEMENTS

1. ENCLOSE OUTDOOR PATIO, CONVERT TO HABITABLE AREA

2. MAIN LEVEL DECK ADDITION

3. THREE BAY WINDOWS

4. REPLACE AT GRADE EXTERIOR STAIR AT SIDE YARD AND ENTRY

5. NEW STANDING SEAM METAL ROOF TO REPLACE EXISTING

6. NEW HORIZONTAL SIDING

7. NEW DOORS AND WINDOW TO REPLACE EXISTING

8. NEW ROOF AT EXISTING ENTRYWAY

9. NEW NEW 6'Ø PRE-FABRICATED, FREESTANDING, SELF CONTAINED JACUZZI.

10. NEW AC COMPRESSOR

SUMMARY OF INTERIOR ARCHITECTURAL IMPROVEMENTS

11. KITCHEN AND BATHROOM REMODEL

SCOPE OF WORK
PARKING 2 COVERED SPACES 1 COVERED NO CHANGE

PROJECT DATA

DESCRIPTION EXISTING PROPOSED TOTAL
LIVING AREA:

BASEMENT 602 S.F. 351 S.F. 953 S.F.

MAIN LEVEL 1,273 S.F. 409 S.F. 1,682 S.F.

TOTAL 1,875 S.F. 760 S.F. 2,635 S.F.

GARAGE 279 S.F. NO CHANGE 279 S.F.

ELEVATED DECK 0 S.F. 300 S.F. 300 S.F.

FIRE DEPARTMENT NOTES

1. A 3'-0" ACCESS PATH IS TO BE MAINTAINED AT ALL TIMES AROUND THE FULL STRUCTURE. NO HAZARDOUS OR FLAMMABLE MATERIALS TO BE STORED OR BLOCKED WITHIN 4'-0" OF THE BUILDING.

2. FIRE FLOW REQUIREMENTS SHALL COMPLY WITH 2019 CFC APP. B.

3. FIRE HYDRANT SYSTEMS & SPACING SHALL COMPLY WITH 2019 CFC APP. C, WITH A MAXIMUM DISTANCE FROM FRONT TO HYDRANT NOT TO EXCEED 250 FEET; "HYDRANT FLOW REPORT" FORM TO BE COMPLETED BY LBCWD OR SCWD.

4. ALL EXTERIOR FIREPLACES AND FIRE PITS MUST BE GAS FIRED ONLY. NO SOLID FUEL IS ALLOWED PER THE LBFD MUNICIPAL CODE. FIREPLACES AND FIRE PITS MUST BE A MINIMUM OF 10 FEET FROM COMBUSTIBLE VEGETATION.

5. MAINTAIN JOBSITE SAFETY DURING CONSTRUCTION AS PER CHAPTER 33 OF THE 2019 CALIFORNIA FIRE CODE.

6. ADDRESS NUMBERS MUST BE PLACED ON THE EXTERIOR FACING THE STREET ADDRESSED TO. MINIMUM SIZE OF NUMBERS IS 4", AND THEY MUST CONTRAST WITH BACKGROUND.

FIRE DEPARTMENT

SITE ACCESS PLAN
3 1 1/8" = 1'-0"

FIRE DEPARTMENT SITE ACCESS PLAN
NORTH
120

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110

STORY POLE CONSTRUCTION NOTES TABLE
DATE:

SITE ADDRESS: 31421 HOLLY DR, LAGUNA BEACH, CA 92651
DATUM BENCHMARK:

NAME OF SURVEYOR OR ENGINEER:

POLE NUMBER BASE GRADE* STORY POLE HEIGHT FROM

BASE GRADE ELEVATION
PROPOSED MAX.

ELEVATION
STAKE #1 RIDGE ELEV 210.5'
STAKE #2 ROOF ELEV 207.9'
EAVE ELEV 207.6'
STAKE #3 ROOF ELEV 207.9'
EAVE ELEV 207.6'
STAKE #4 RIDGE ELEV 210.5'
STAKE #5 ROOF ELEV 207.9'
EAVE ELEV 207.6'
STAKE #6 ROOF ELEV 207.9'
EAVE ELEV 207.6'
STAKE #7 RAILING 200.75'
STAKE #8 RAILING 200.75'
STAKE #9 ROOF ELEV 205.5'
STAKE #10 ROOF ELEV 205.38'
STAKE #11 ROOF ELEV 205.38'
STAKE #12 ROOF ELEV 205.5'
*IF STANDARD BASE GRADE ELEVATION NAILS ARE NOT FEASIBLE BECAUSE OF THE EXISTENCE OF ROCKS, PAVING

OR EXISTING STRUCTURAL IMPROVEMENTS, THEN THE SURVEYOR OR ENGINEER MAY USE AN ALTERNATIVE

METHOD OF ESTABLISHING HORIZONTAL AND VERTICAL CONTROL FOR STORY POLES THAT CAN BE OBSERVED IN THE FIELD. THE SURVEYOR OR ENGINEER SHALL DESCRIBE THE CONTROL METHOD USED DIRECTLY ON THE FULL-SIZE STAKING PLAN. SUCH ALTERNATIVE METHODS MAY INCLUDE PAINTED MARKINGS. IT IS ALSO RECOGNIZED THAT SOMETIMES IT MAY NOT BE FEASIBLE TO SET POLES DUE TO UNFORESEEN CIRCUMSTANCES. IN

THAT CASE, PLEASE IDENTIFY THE STORY POLES THAT WERE NOT ESTABLISHED AND AN EXPLANATION AS TO THE REASON.

STAKE (1)
RIDGE ELEV 210.5'
(13'-3" ABOVE
MAIN LEVEL F.F.)
STAKE (5)
ROOF ELEV 207.9'
(10'-8" ABOVE
MAIN LEVEL F.F.)
EAVE ELEV 207.6'
(10'-4" ABOVE
MAIN LEVEL F.F.)
STAKE (6)
ROOF ELEV 207.9'
(10'-8" ABOVE
MAIN LEVEL F.F.)
EAVE ELEV 207.6'
(10'-4" ABOVE
MAIN LEVEL F.F.)
STAKE (3)
ROOF ELEV 207.9'
(10'-8" ABOVE MAIN LEVEL F.F.)
EAVE ELEV 207.6'
(10'-4" ABOVE MAIN LEVEL F.F.)
STAKE (2)
ROOF ELEV 207.9'
(10'-8" ABOVE MAIN LEVEL F.F.)
EAVE ELEV 207.6'
(10'-4" ABOVE MAIN LEVEL F.F.)
STAKE (4)
RIDGE ELEV 210.5'
(13'-3" ABOVE
MAIN LEVEL F.F.)
31421 HOLLY DRIVE
℄ HOLLY DRIVE

STORY POLES SHALL BE STRUNG AND CONNECTED WITH RIBBON AND STRINGLINES TO DEPICT THE BUILDING OUTLINE.

PLEASE STAMP & SIGN BELOW

SIGNATURE OF REGISTERED LAND SURVEYOR OR CIVIL ENGINEER

NAME (PRINTED OR TYPED)
LICENSE NO. / EXPIRATION DATE
DATE

STORY POLE HEIGHT AND LOCATION CERTIFICATION
INSTRUCTIONS:

THE STORY POLE HEIGHT AND LOCATION CERTIFICATION AND STORY POLE CONSTRUCTION NOTES TABLE OR

NOTATIONS MUST BE EXECUTED BY A REGISTERED LAND SURVEYOR OR REGISTERED CIVIL ENGINEER DIRECTLY ON A COPY OF THE FULL-SIZE ROOF PLAN. THE COMPLETED CERTIFICATION MUST BE SUBMITTED TO THE CITY AT LEAST 28 DAYS PRIOR TO THE DESIGN REVIEW AUTHORITY’S FIRST NOTICED PUBLIC HEARING DATE (OR 14 DAYS PRIOR TO ADMINISTRATIVE DESIGN REVIEW HEARING OR A DESIGN REVIEW CONTINUANCE).

REQUIRED CERTIFICATION STATEMENT:

I HEREBY CERTIFY THAT THE STORY POLES LOCATED ON THE REFERENCED SITE WERE CONSTRUCTED UNDER MY

SUPERVISION AND SURVEY, AND THE STORY POLES ARE IN CONFORMANCE WITH THE DESIGN, HEIGHT AND LOCATION AS SHOWN ON THE APPROVED STAKING PLAN. I FURTHER CERTIFY THAT 1) THE STORY POLE IDENTIFICATION NUMBERS, 2) STORY POLE LOCATION BASE GRADE ELEVATIONS, 3) STORY POLE HEIGHTS AND 4) THE PROPOSED MAXIMUM HEIGHT ELEVATIONS ARE TRUE AND CORRECT. I ACKNOWLEDGE AND UNDERSTAND THAT THE REQUIRED

PROJECT STAKING IS FOR THE PURPOSE OF INFORMING THE OWNER, ARCHITECT, DESIGNER, CITY STAFF, DESIGN

REVIEW AUTHORITY AND THE PUBLIC AS TO THE ACCURATE LOCATION AND EXTERIOR DIMENSIONS OF THE PROPOSED STRUCTURE OR ADDITION.

STAKE (7)
RAILING 200.75'
(3'-6" ABOVE
MAIN LEVEL F.F.)
STAKE (8)
RAILING 200.75'
(3'-6" ABOVE
MAIN LEVEL F.F.) VARIES
VARIES

OUTRIGGER FOR

STAKING EAVES
7'-4" 10'-8" 2'-8" 16'-9"
3'-4"
28'-6" 10'-0"
4'-10"

EXISTING ROOF

TO REMAIN

EXISTING ROOF

TO REMAIN

PROPOSED ROOF
2'-1" 4'-0" 3'-0" 1'-0"
STAKE (9)
ROOF ELEV 205.5'
(8'-3" ABOVE
MAIN LEVEL F.F.)
STAKE (10)
ROOF ELEV 205.38'
(8'-2" ABOVE MAIN
LEVEL F.F.)
3'-0"
STAKE (11)
ROOF ELEV 205.38'
(8'-2" ABOVE MAIN
LEVEL F.F.)
STAKE (12)
ROOF ELEV 205.5'
(8'-3" ABOVE
MAIN LEVEL F.F.)

SURVEY /

STAKING PLAN
4 1 1/8" = 1'-0"

STAKING PLAN
NORTH
121

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110

LIGHT FIXTURE LEGEND

SOFFIT RECESSED LED DOWNLIGHT,
3 WATTS MAX. 365 LUMENS
LED WALL MOUNTED DOWN LIGHT FIXTURE, 3 WATTS MAX. 365
LUMENS. MODERN FORMS LED WALL LIGHT, 'TWO IF BY SEA'

TOP OF FIXTURE TO BE OPAQUE
SYM. QTY. DESCRIPTION
4 1

EXTERIOR DOOR
10 LED RECESSED STAIR TREAD LIGHT, 3 WATTS MAX. 365 LUMENS.

MODERN FORMS OUTDOOR LED

WALL LIGHT, 'TWO IF BY SEA'

EXTERIOR LIGHTING
PLANS
5 2 1/8" = 1'-0"
BASEMENT EXTERIOR LIGHTING PLAN 1 1/8" = 1'-0"MAIN LEVEL EXTERIOR LIGHTING PLAN 122

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110

LANDSCAPED OPEN
SPACE

EXISTING

BUILDING SITE COVERAGE
2,124 SQ.FT.

PROPOSED

BUILDING SITE COVERAGE
11 SQ.FT.

EXISTING

BUILDING SITE COVERAGE
2,124 SQ.FT.

PROPOSED

BUILDING SITE COVERAGE
14 SQ.FT.

PROPOSED ENCLOSED

BUILDING AREA

EXISTING ENCLOSED

BUILDING AREA

AREA CALCULATIONS LEGEND

HARDSCAPE

HARDSCAPE
209 SQ.FT.

HARDSCAPE
221 SQ.FT.

AREA CALCULATIONS
:EXISTING BUILDING SITE COVERAGE
59'-9" x 44'-3" 2,124 SQ.FT.
2,124 SQ.FT.
:HARDSCAPE
24'-8"
61'-2"
x
x
17'-4"
54'-6"
209 SQ.FT.
221 SQ.FT.
430 SQ.FT.
:LANDSCAPE OPEN SPACE
138'-7" x 55'-2" 4,316 SQ.FT.
4,316 SQ.FT.
6,871 SQ.FT.

HARDSCAPE
271 SQ.FT.

AREA CALCULATIONS
:BUILDING SITE COVERAGE

EXISTING

PROPOSED
59'-9"
9'-11"
2'-8"
x
x
x
44'-3"
1'-7"
5'-0"
2,124 SQ.FT.
11 SQ.FT.
14 SQ.FT.
2,149 SQ.FT.
2,149 SQ.FT.
:HARDSCAPE
31'-9"
61'-1"
x
x
21'-9"
54'-6"
430 SQ.FT.
271 SQ.FT.
702 SQ.FT.
702 SQ.FT.
:LANDSCAPE OPEN SPACE
13'-3"
4'-4"
131'-8"
x
x
x
32'-9"
2'-11"
54'-6"
307 SQ.FT.
13 SQ.FT.
3,717 SQ.FT.
4,037 SQ.FT.
4,037 SQ.FT.
6,887 SQ.FT.

HARDSCAPE
430 SQ.FT.

LANDSCAPE OPEN SPACE
4,316 SQ.FT.
--

LANDSCAPE OPEN SPACE
307 SQ.FT.

LANDSCAPE OPEN SPACE
13 SQ.FT.

LANDSCAPE OPEN SPACE
3,717 SQ.FT.
--

BUILDING SITE

COVERAGE

CALCULATION
7 1 1/8" = 1'-0"
EXISTING SITE COVERAGE 2 1/8" = 1'-0"PROPOSED SITE COVERAGE 123

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
1/4" = 1'-0"
EXISTING GARAGE AREA CALCULATIONS 3
1/4" = 1'-0"
EXISTING BASEMENT AREA CALCULATIONS 2
1/4" = 1'-0"
EXISTING MAIN LEVEL AREA CALCULATIONS 1
X
G1
20'-1"
279 SQ.FT.
13'-10"
X
M1
22'-0"
622 SQ.FT.
28'-3" X
M2
47'-0"
651 SQ.FT.
13'-10"
X
B1
32'-5"
475 SQ.FT.
14'-8" X
B2
13'-2"
127 SQ.FT.
9'-8"

EXISTING AREA

CALCULATIONS
:BASEMENT

EXISTING
B1
B2
32'-5"
13'-2"
x
x
14'-8"
9'-8"
475 SQ.FT.
127 SQ.FT.
602 SQ.FT.
602 SQ.FT.
:MAIN LEVEL

EXISTING
M1
M2
22'-0"
47'-0"
x
x
28'-3"
13'-10"
622 SQ.FT.
651 SQ.FT.
1,273 SQ.FT.
1,273 SQ.FT.
:GARAGE

EXISTING
G1 20'-1" x 13'-10" 279 SQ.FT.
279 SQ.FT.
279 SQ.FT.
:MECHANICAL / STORAGE

EXISTING
B3
B4
B5
28'-3"
13'-10"
9'-8"
x
x
x
5'-4"
13'-5"
1'-6"
151 SQ.FT.
185 SQ.FT.
15 SQ.FT.
351 SQ.FT.
351 SQ.FT.
2,504 SQ.FT.

EXISTING

TO REMAIN

EXISTING
GARAGE

EXISTING

COVERED PATIO
--
X

COVERED PATIO
14'-0"
396 SQ.FT.
28'-3"

AREA CALCULATION
LEGEND

EXISTING

MECHANICAL / STORAGE
X
B5
9'-8"
15 SQ.FT.
1'-6"
X
B4
13'-10"
185 SQ.FT.
13'-5"
X
B3
28'-3"
151 SQ.FT.
5'-4"
NORTH
NORTH
NORTH

EXISTING AREA

CALCULATIONS
8 124

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
1/4" = 1'-0"
EXISTING GARAGE AREA CALCULATIONS 3
1/4" = 1'-0"
PROPOSED BASEMENT AREA CALCULATIONS 2
1/4" = 1'-0"
PROPOSED MAIN LEVEL AREA CALCULATIONS 1
X
G1
20'-1"
279 SQ.FT.
13'-10"
X
M1
22'-0"
622 SQ.FT.
28'-3"
X
M2
47'-0"
651 SQ.FT.
13'-10"

PROPOSED AREA

CALCULATIONS
:BASEMENT

EXISTING
NEW
B1
B4
B3
B4
B5
32'-5"
13'-2"
28'-3"
13'-10"
9'-8"
x
x
x
x
x
14'-8"
9'-8"
5'-4"
13'-5"
1'-6"
475 SQ.FT.
127 SQ.FT.
602 SQ.FT.
151 SQ.FT.
185 SQ.FT.
15 SQ.FT.
351 SQ.FT.
953 SQ.FT.
:MAIN LEVEL

EXISTING

PROPOSED
M1
M2
NM1
NM2
22'-0"
47'-0"
14'-0"
1'-0"
x
x
x
x
28'-3"
13'-10"
28'-3"
13'-3"
622 SQ.FT.
651 SQ.FT.
1,273 SQ.FT.
396 SQ.FT.
14 SQ.FT.
409 SQ.FT.
1,682 SQ.FT.
:GARAGE

EXISTING
G1 20'-1" x 13'-10" 279 SQ.FT.
279 SQ.FT.
279 SQ.FT.
:DECK
DECK D1 10'-6" x 28'-6" 300 SQ.FT.
300 SQ.FT.
300 SQ.FT.
3,214 SQ.FT.

AREA CALCULATION
LEGEND

EXISTING TO REMAIN

EXISTING GARAGE

PROPOSED AREA
X
B1
32'-5"
475 SQ.FT.
14'-8"
X
B4
13'-2"
127 SQ.FT.
9'-8"

PROPOSED DECK
X
NM1
14'-0"
396 SQ.FT.
28'-3"
X
D1
10'-6"
300 SQ.FT.
28'-6"
--
X
B5
9'-8"
15 SQ.FT.
1'-6"
X
B4
13'-10"
185 SQ.FT.
13'-5"
X
B3
28'-3"
151 SQ.FT.
5'-4"
X
NM2
1'-0"
14 SQ.FT.
13'-3"
NORTH
NORTH
NORTH
DN
4'-4" S.Y.S.B. 5'-0" GARAGE F.Y.S.B
⅊

LINE OF EXISTING HOUSE

ABOVE (ALL HOUSE

AREA IS CLEAR OF THE

FRONT YARD SETBACK)
⅊
⅊
4'-4" S.Y.S.B.
⅊
4'-4" S.Y.S.B.
7'-1" S.Y.S.B. 10'-0" F.Y.S.B
⅊
7'-1" S.Y.S.B.
⅊

PROPOSED AREA

CALCULATIONS
9 125

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110

REPLACE EXISTING

BEAM TO REMOVE
POST

LAUNDRY
13'-2"x10'-10"
CLOSET
6'-5"x5'-2"

BEDROOM
11'-8"x13'-2"

BATHROOM
7'-11"x7'-9"

BEDROOM
12'-3"x13'-2" KITCHEN12'-4"x9'-9" DINING
18'-1"x12'-4"
LIVING
ROOM
9'-0"x18'-2" ENTRY10'-3"x9'-0" CLOSET
2'-1"x9'-9"
1 1
2 2
2 3
3 4
5 6 W20 4'-10" W21 3'-6" W22 8'-3" W23 12'-5" W24 4'-7" W27 3'-0" W28 8" W29
14'-9"
W30
8'-3"
W31
3'-7"
W32
15'-3"
W33
5" W34 22'-2"
W38
14'-0"
W35
27'-10" W36 13'-4" W37 11'-8" DEMOLITION DEMOLITION DEMO.

DEMOLITION DEMOLITION DEMOLITION

DEMOLITION
13 A
14 A
15 A
16 A
WINDOW CHANGE OUT INFILL INFILL W26 6'-11" W25 3'-0" DEMO. INFILL INFILL

PARTITION TO BE

REMOVED

EXISTING DOOR TO
REMAIN

EXISTING PARTITION TO
REMAIN

DEMOLITION LEGEND

DOOR TO BE

REMOVED

DEMOLITION KEYNOTES DEMOLITION GENERAL NOTES

CUTBACK EXISTING TERRACED LANDSCAPE WALLS AS REQUIRED FOR NEW ENTRY STAIRS

CUT OPENING IN FLOOR FOR NEW STAIR TO BASEMENT, REFERENCE NEW WORK PLANS

EXISTING CABINETS AND APPLIANCES TO BE REMOVED
1 2
3 4
5 6

EXISTING STAIR TO BE REMOVED

EXISTING CHIMNEY TO BE REMOVED

1. CONTRACTOR SHALL REMOVE ALL EXISTING ITEMS THAT INTERFERE OR CONFLICT WITH THE NEW CONSTRUCTION AS INDICATED WITHIN THIS SET OF DRAWINGS.

SOME EXISTING ITEMS NOT SHOWN IN THIS SET, BUT ARE CONSIDERED TO BE A

PART OF MINOR DEMOLITION INCLUDE ABANDONED SWITCHES, RECEPTACLES, THERMOSTATS, PIPES, CONDUIT, ETC. ALL THESE EXISTING ITEMS ARE TO BE

REMOVED IF THEY CONFLICT WITH NEW WORK OR ARE NOT SPECIFICALLY NOTED TO REMAIN. GENERAL CONTRACTOR TO COORDINATE INITIAL SITE WALK TO HIGHLIGHT SPECIFIC DEMOLITION ITEMS WITH OWNER AND ARCHITECT.

2. SMOKE DETECTION AND EXISTING FIRE ALARM SYSTEMS SHALL BE MAINTAINED BY THE CONTRACTOR DURING ALL PHASES OF CONSTRUCTION. ANY DAMAGES TO THE

SYSTEM SHALL BE IMMEDIATELY REPAIRED TO THE SATISFACTION OF THE ARCHITECT.

3. CONTRACTOR SHALL INSTALL A TEMPORARY AIR FILTER IN THE RETURN AIR DUCT THROUGH THE DEMOLITION & CONSTRUCTION PHASE. ALL MECHANICAL GRILLES, FANS, HOODS, ETC. TO BE COVERED AND PROTECTED DURING DEMOLITION TO ELIMINATE DUST AND DEBRIS FROM ENTERING THE EXISTING SYSTEM.

4. DURING CONSTRUCTION PROTECT ALL EXISTING DOORS, APPLIANCES, LIGHT FIXTURES, ETC AND ANY OTHER BUILDING ITEMS TO REMAIN.

EXISTING PLUMBING FIXTURES TO BE REMOVED. REMOVE ABANDONED PLUMBING

LINES TO MAIN
W50
14'-0" W51 20'-3"
GARAGE
19'-5"x13'-2" 1
4 W52
14'-0" W53 20'-3"
13 C
15 A
16 A

EXISTING

TRELLIS ABOVE

TO BE REMOVED

EXISTING MAIN

LEVEL ABOVE

EXISTING POST

TO BE REMOVED

BEDROOM
12'-6"x17'-1"
CLOSET
7'-5"x3'-11" CLOSET6'-3"x4'-3"

BEDROOM
13'-10"x14'-0"

BATHROOM
6'-3"x5'-10"
1 2
W4
14'-3"
W5
9'-5"
W6
2'-11"
W7
8'-3"
W8
3'-7"
W9
2'-0"
W10
1'-10" W13 14'-1" W12 2'-0" W11 4'-1"
DEMO. DEMOLITION DEMOLITION DEMO.

W16
14'-0"
W14
28'-3" W15 8'-0"

WALL DEMOLITION CALCULATION
14 A
15 A
16 A

LABEL EXISTING DEMOLITION

BASEMENT
W1 7'-5"
W2 2'-0"
W3 18'-9"
W4 14'-3"
W5 9'-5"
W6 2'-11"
W7 8'-3"
W8 3'-7"
W9 2'-0"
W10 1'-10"
W11 4'-1"
W12 2'-0"
W13 14'-1"
W14 28'-3"
W15 8'-0"
W16 14'-0"

MAIN LEVEL
W20 4'-10"
W21 3'-6"
W22 8'-3"
W23 12'-5"
W24 4'-7"
W25 3'-0"
W26 6'-11"
W27 3'-0"
W28 0'-8"
W29 14'-9"
W30 8'-3"
W31 3'-7"
W32 15'-3"
W33 0'-5"
W34 22'-2"
W35 27'-10"
W36 13'-4"
W37 11'-8"
W38 14'-0"
GARAGE
W50 14'-0"
W51 20'-3"
W52 14'-0"
W53 20'-3"
277'-6" L.F. 110'-3" L.F.
110'-3" (L.F. OF WALLS TO BE REMOVED)
387'-9" (L.F. FEET OF EXISTING WALLS)
28%
WINDOW CHANGE OUT W1 7'-5" W2 2'-0" W3 18'-9" DEMO. INFILL

DEMOLITION PLANS
10 2 1/4" = 1'-0"

MAIN LEVEL DEMOLITION PLAN
3 1/4" = 1'-0"

GARAGE REFERENCE PLAN
1 1/4" = 1'-0"

BASEMENT DEMOLITION PLAN
NORTH
NORTH
NORTH
126

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
BAR
5'-5" X 2'-0"
LINEN

LINE OF EXISTING

GARAGE ABOVE

EXISTING

RIDGE ABOVE

EXISTING

BEAM ABOVE
DW
BENCH

ROOF ABOVE
PLANTER 5'-3" 4'-5" 5'-9"
4'-6"
UNDER

COUNTER
FRIDGE

MICROWAVE
DRAWER
MASTER
CLOSET
8'-0"x15'-9"
POWDER
9'-9"x5'-7"
ENTRY
6'-9"x15'-11" MASTER

BATHROOM
12'-5"x10'-8"
MASTER

BEDROOM
11'-3"x17'-3" LIVING
ROOM
18'-9"x14'-0" DINING
ROOM
13'-10"x18'-9"

KITCHEN
15'-11"x17'-9"
COAT
CLOSET
5'-3"x2'-6"
PANTRY
4'-6"x4'-8"
DECK
10'-0"x28'-6"

WINDOW SEAT
1'-0" 2'-3"
8'-6" 2'-6"

CANTILEVERED

BAY WINDOW

CANTILEVERED
BAY WINDOW 13'-3"
28'-6" 10'-0"
T.O. MAIN LEVEL F.F.
197'-3"
T.O. DECK F.S.
197'-1"
13 B
14 B
15 B
16 B
17 A

BUILT-IN
DESK
UP UP
T.O. PATIO F.S.
196'-10"
T.O. LANDING
198'-1"
T.O. LANDING
200'-7"
T.O. LANDING
203'-1"
T.O. LANDING
206'-3"

LANDING AT EXISTING GRADE
4'-0"
⅊
4'-4" S.Y.S.B.
7'-1" S.Y.S.B. 10'-0" F.Y.S.B
⅊
NEW 6'Ø PRE-FABRICATED,

FREESTANDING, SELF
CONTAINED JACUZZI. BUILT-IN

SEATING
17" HIGH STEP /
SEAT AROUND 6' Ø

JACUZZI
5'-0"
17 B
DN ENTRY BENCH 5'-7"
14'-0" 20'-3"COVERED PARKING
SPACE #1
8'-8"x18'-0"
GARAGE
19'-5"x13'-2"
T.O. GARAGE F.F.
206-3"
13 D
15 B
16 B
17 A DN
DN
13'-2" 19'-5"
T.O. LANDING
206'-3"

LANDING AT EXISTING GRADE
⅊
4'-4" S.Y.S.B. 5'-0" GARAGE F.Y.S.B
TRASH

STORAGE

MURPHY BED
LINEN
BEDROOM 1
13'-2"x12'-5" SITTING
ROOM
12'-6"x10'-0" BEDROOM 211'-7"x12'-6" BATHROOM 25'-4"x12'-6" CLOSET
6'-4"x6'-8" LAUNDRY6'-4"x10'-4" BATHROOM 1
9'-0"x8'-0"
CLOSET
6'-0"x9'-0"
LINEN

LINE OF EXISTING HOUSE

ABOVE (ALL HOUSE

AREA IS CLEAR OF THE

FRONT YARD SETBACK)

OUTDOOR SHOWER
T.O. BASEMENT F.F.
188'-7"
14 B
15 B
16 B
17 A

DECK ABOVE
⅊
4'-4" S.Y.S.B.
7'-1" S.Y.S.B.
⅊
UP

NEW DOOR

EXISTING WALL & DOOR

TO REMAIN

NEW PARTITION WALL

FLOOR PLAN LEGEND

ROOM NUMBER

ROOM NAME ROOM
NAME
100

ELEVATION REFERENCE

SHEET NUMBER

VIEW NUMBER

FLOOR PLAN GENERAL NOTES

1. PRIOR TO COMMENCEMENT OF ANY WORK, GENERAL CONTRACTOR TO VERIFY EXISTING SITE CONDITIONS AND DIMENSIONS. NOTIFY ARCHITECT IMMEDIATELY IF THERE ARE ANY DIMENSIONAL DISCREPANCIES.

2. ALL INTERIOR WALLS TO BE 5
8" GYPSUM WALL BOARD WITH SMOOTH PREP COAT
READY TO RECEIVE PAINT. PROVIDE L METAL AT ALL CORNERS U.N.0.

3. ALL SHOWER & BATHTUB WALLS TO BE STUCCO BROWN AND SCRATCH COAT OVER METAL LATH & GRADE "D" BUILDING PAPER PRIOR TO FINISH MATERIALS.

4. PROVIDE BATT INSULATION AT ALL INTERIOR WALLS AND FLOORS.

5. ALL DIMENSIONS ARE TO FACE OF STUD, U.N.O.

6. HVAC AND PLUMBING TO BE DESIGN BUILD. VERIFY FAU/WH SIZE AND LOCATIONS INCLUDING POWER REQUIREMENTS WITH OWNER AND ARCHITECT. VERIFY SIZE,

TYPE & LOCATION OF ALL SUPPLY & RETURN GRILLES WITH ARCHITECT PRIOR TO INSTALLATION. ALL HVAC GRILLES TO BE "REGGIO REGISTERS' OR APPROVED EQUAL.

VERIFY FINISH AND STYLE.

7. ALL BATHROOMS CONTAINING BATHTUBS, SHOWERS, SPAS AND SIMILAR BATHING FIXTURES SHALL BE MECHANICALLY VENTED PER THE CALIFORNIA MECHANICAL CODE.

8. PROVIDE 70 INCH HIGH NON-ABSORBENT WALL ADJACENT TO SHOWER AND APPROVED SHATTER-RESISTANT MATERIALS FOR SHOWER ENCLOSURE.

9. PATCH AND REPAIR ANY DAMAGED WALL AREAS OR VOIDS IN WALLS FROM

ABANDONED OUTLET, SWITCHES, ACCESS PANELS OR WALL INTERSECTIONS RESULTING FROM DEMOLITION.

10. SEAL AROUND ALL PENETRATIONS, DUCTS, PIPES, CONDUITS, ETC. AT FIRE RATED WALL AND CEILING CONSTRUCTION.

11. EXTERIOR WALLS SHALL BE APPROVED NON-COMBUSTIBLE OR IGNITION RESISTANT

MATERIAL AND SHALL PROVIDE PROTECTION FROM THE INTRUSION OF FLAMES AND EMBERS IN ACCORDANCE WITH CITY STANDARDS.

12. FACTORY-BUILT FIREPLACES SHALL HAVE ALL OF THE FOLLOWING: [150(E)] A. CLOSABLE METAL OR GLASS DOORS COVERING THE ENTIRE OPENING OF THE FIREBOX.

B. A COMBUSTION AIR INTAKE TO DRAW AIR FROM THE OUTSIDE WHICH IS AT LEAST 6 SQUARE INCHES IN ARA AND IS EQUIPPED WITH A READILY ACCESSIBLE OPERABLE AND TIGHT-FITTING DAMPER OR COMBUSTION-CONTROL DEVICE.

EXCEPTION: NOT REQUIRED IF INSTALLED OVER A CONCRETE SLAB FLOORING AND LOCATED ON AN EXTERIOR WALL.

C. A FLUE DAMPER WITH A READILY ACCESSIBLE CONTROL. EXCEPTION: WHEN A GAS

LOG, LOG LIGHTER OR DECORATIVE GAS APPLIANCE IN INSTALLED IN A FIREPLACE, THE FLUE DAMPER SHALL BE BLOCKED OPEN.

13. PROVIDE A LANDING AT EACH SIDE OF THE DOOR - LANDING WIDTH TO MATCH THE DOOR WIDTH. LANDING WIDTH SHOULD NOT BE LESS THAN 36". THE ELEVATION OF THE LANDING SHALL NOT EXCEED 1
1 2" DIFFERENCE THAN THE THRESHOLD OF THE
DOORWAY (7
3 4" IF DOOR DOES NOT SWING OVER THE LANDING OR STEPS) IN EACH DIRECTION. THE MAX. SLOPE OF THE LANDING SHALL NOT EXCEED 1 4" PER FOOT.
(CRC R311.3.1)

14. A WATER-RESISTIVE BARRIER SHALL BE INSTALLED AS REQUIRED IN SECTION 1404.2

CBC AND, WHERE APPLIED OVER WOOD-BASED SHEATHING, SHALL INCLUDE A

WATER-RESISTIVE VAPOR-PERMEABLE BARRIER WITH A PERFORMANCE AT LEAST EQUIVALENT TO TWO LAYERS OF GRADE D PAPER PER CBC 2510.6 XXXX
X

NEW WORK PLANS
11 2 1/4" = 1'-0"

MAIN LEVEL NEW WORK PLAN
3 1/4" = 1'-0"

GARAGE REFERENCE PLAN
1 1/4" = 1'-0"

BASEMENT NEW WORK PLAN
NORTH
NORTH
NORTH
127

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110

GENERAL NOTES FLASHING NOTES

1. ALL FLASHING TO BE 16 OZ COPPER.

2. VALLEY FLASHING SHALL NOT BE LESS THAN 0.019-INCH (0.48 MM) (NO. 26 GAUGE GALVANIZED SHEET GUAGE) CORROSION-RESISTANT METAL INSTALLED OVER A MINIMUM 36" WIDE (914 MM) UNDERLAYMENT CONSISTING OF ONE LAYER OF NO. 72 ASTM CAP SHEET RUNNING THE FULL LENGTH OF THE VALLEY.

3. PROVIDE EDGE FLASHING AT ALL EAVES & RAKES

4. PROVIDE FLASHING AT ALL RIDGES, VALLEYS AND HIPS

5. AT DORMERS PROVIDE EDGE FLASHING AT EAVE & RAKE, PROVIDE

FLASHING AT VALLEY BEHIND DORMER AT SIDES (ROOF TO WALL) AND AT FRONT ROOF TO WALL.

6. PROVIDE FLASHING AT ALL ROOF PENETRATIONS. WHERE VENT IS VISIBLE PROVIDE EYEBROW VENT.

7. PROVIDE CRICKET & FLASHING AT CHIMNEY AS REQUIRED.

8. PROVIDE FLASHING AT ALL ROOF TO WALL CONDITIONS.

9. PROVIDE FLASHING AT ALL DOOR & WINDOW HEADS.

10. PROVIDE SILL PANS AT ALL EXTERIOR DOORS.

11. PROVIDE WATER TABLE FLASHING AT ENTIRE PERIMETER OF BUILDING.

12. PROVIDE CAP FLASHING AT DECK CURB & GUARDRAIL.

1. FINISH ROOF TO BE CLASS "A", OVER "GRACE" ICE & WATER SHIELD

SELF-ADHERED UNDERLAYMENT OVER TONGUE AND GROOVE SHEATHING, ESR-1677, INSTALL PER MANUFACTURER REQUIREMENTS. FOR ROOFS WITH LESS THAN A 4:12 PITCH PROVIDE A DOUBLE LAYER OF UNDERLAYMENT.

2. PROVIDE TWO LAYERS OF UNDERLAYMENT FOR ALL ROOF SLOPES LESS THAN 4:12

3. PROVIDE 6" HALF ROUND COPPER GUTTERS & 4" ROUND COPPER DOWN SPOUTS. INSTALL PER MANUFACTURER REQUIREMENTS. VERIFY LAYOUT WITH ARCHITECT.

4. LOCATE ALL THROUGH ROOF PENETRATIONS AT REAR YARD SIDE OF RIDGE.

ALL ROOF PENETRATIONS FOR VENTS ON SLOPED SURFACES TO BE APPROXIMATELY MIDWAY BETWEEN RIDGE & EAVE. VERIFY EXACT LOCATIONS WITH ARCHITECT.

5. PROVIDE ATTIC VENTILATION EQUAL TO 1/150 OF ATTIC AREA MINIMUM.

PER CODE SECTION 1505.3

6. MECHANICAL SUBCONTRACTOR TO PROVIDE SPECIFICATIONS AND CUT

SHEETS OF ALL HVAC EQUIPMENT (INCLUDING SUPPLY/RETURN REGISTERS) FOR ARCHITECTS APPROVAL.

7. PROVIDE OVERFLOW DRAINS AS REQUIRED.

8. ROOF GUTTERS SHALL BE PROVIDED WITH THE MEANS TO PREVENT THE ACCUMULATION OF LEAVES AND DEBRIS INSIDE THE GUTTER.

9. ROOF, ATTIC AND EXTERIOR WALL VENTS SHALL RESIST THE INTRUSION OF

FLAME AND EMBERS INTO THE ATTIC AREA OF THE STRUCTURE, OR SHALL

BE PROTECTED BY CORROSION-RESISTANT, NONCOMBUSTIBLE WIRE MESH WITH 1/4-INCH (6 MM) OPENINGS OR ITS EQUIVALENT. VENTS SHALL NOT BE INSTALLED IN EAVES AND CORNICES.
1 2:12
1:12
1:12 3:12 3:12 T.O. PROPOSED RIDGE = 210.5' (13'-3" ABOVE MAIN LEVEL F.F.)

EXISTING ROOFING TO BE

REPLACED WITH CLASS 'A'

STANDING SEAM METAL ROOF
NEW ROOF AT EXISTING ENTRYWAY.

ROOFING MATERIAL TO BE CLASS 'A'
STANDING SEAM METAL ROOF.

PROVIDE GUTTERS AND DOWNSPOUTS

TIED INTO EXISTING DRAINAGE SYSTEM
1'-0" 7'-4" 2'-8" 1'-0"
1'-0"
T.O. PROPOSED EAVE ELEV = 207.6'
(10'-4" ABOVE MAIN LEVEL F.F.)
T.O. PROPOSED EAVE ELEV = 207.6'
(10'-4" ABOVE MAIN LEVEL F.F.)
T.O. PROPOSED
EAVE ELEV = 207.6'
(10'-4" ABOVE
MAIN LEVEL F.F.)
T.O. PROPOSED
EAVE ELEV = 207.6'
(10'-4" ABOVE
MAIN LEVEL F.F.)
T.O. EXISTING EAVE = 206.29'
(9'-0" ABOVE MAIN LEVEL F.F.)
T.O. EXISTING EAVE = 205.04'
(7'-10" ABOVE MAIN LEVEL F.F.)
T.O. EXISTING EAVE = 214.91'
(17'-8" ABOVE MAIN LEVEL F.F.)
T.O. EXISTING EAVE = 214.91'
(17'-8" ABOVE MAIN LEVEL F.F.)
T.O. EXISTING EAVE = 205.42'
(18'-6" ABOVE MAIN LEVEL F.F.)
T.O. EXISTING EAVE = 205.42'
(18'-6" ABOVE MAIN LEVEL F.F.)
T.O. EXISTING EAVE = 205.42'
(8'-2" ABOVE MAIN LEVEL F.F.)
T.O. EXISTING EAVE = 206.91'
(9'-8" ABOVE MAIN LEVEL F.F.)
T.O. EXISTING EAVE = 205'
(7'-9" ABOVE MAIN LEVEL F.F.)
T.O. EXISTING EAVE = 205'
(7'-9" ABOVE MAIN LEVEL F.F.)

EXISTING CHIMNEY

TO BE REMOVED

EXISTING AREA OF

ROOF TO BE

DEMOLISHED

SHOWN DASHED
1 2:12 1:12
1:12
1 2:12
22'-4" 16'-3"

EXISTING CHIMNEY

TO BE REMOVED
ELEVATED DECK 0 S.F. 300 S.F. 300 S.F.

MECHANICAL / STORAGE 351 S.F. -351 S.F. 0 S.F.

BASEMENT 602 S.F. 0 S.F. 602 S.F. 0%
MAIN LEVEL 1,273 S.F. 0 S.F. 1,273 S.F. 0%

ROOF PLANS
12 2 1/4" = 1'-0"

PROPOSED ROOF PLAN
1 1/4" = 1'-0"

EXISTING ROOF PLAN

NORTHNORTH
128

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
12 3"
T.O. MAIN LEVEL F.F.
197'-3"
⅊ ⅊
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB
7'-1"
S.Y.S.B.
4'-4"
S.Y.S.B.

NEW 6'-0" HIGH

WOOD FENCE
T.O. UPPER CURB
206'-0"
6 7
9 10
T.O. GARAGE F.F.
206-3"
T.O. ROOF
215'-9"
T.O. MAIN LEVEL F.F.
197'-3" 8'-0" CEILING HEIGHT
12 1" 12'-3
34 "
T.O. ROOF
206'-11" 8'-0"
4'-0"
T.O. MAIN LEVEL F.F.
197'-3"
⅊ ⅊
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB
7'-1"
S.Y.S.B.
4'-4"
S.Y.S.B.
2 3
T.O. CHIMNEY
209-3"
T.O. GARAGE F.F.
206-3"
T.O. ROOF
215'-9"
T.O. MAIN LEVEL F.F.
197'-3" 8'-0" CEILING HEIGHT
12 1"
T.O. UPPER CURB
206'-0"
T.O. ROOF
206'-11" 8'-0"
12 1"
T.O. GARAGE F.F.
206-3"
T.O. ROOF
215'-9"
T.O. WALL
210-7"
8 8
9 11 11
12 1"
T.O. GARAGE F.F.
206-3"
T.O. ROOF
215'-9"
T.O. WALL
210-3"

ELEVATION KEYNOTES
EXISTING ROOFING TO BE REPLACED WITH CLASS 'A' STANDING SEAM METAL ROOF.

PROVIDE GUTTERS AND DOWNSPOUTS TIED INTO EXISTING DRAINAGE SYSTEM

EXISTING ROOF TO BE REPLACED WITH NEW ENTRY ROOF
1 2
3 4
5 6

EXISTING STAIR TO BE REPLACED, REFERENCE NEW WORK PLANS

EXISTING WINDOWS / DOOR TO BE REMOVED, REFERENCE NEW WORK PLANS FOR

REVISED OPENING

EXISTING CHIMNEY TO BE REMOVED

CUT OPENING FOR NEW DOOR OR WINDOW, REFERENCE NEW WORK PLANS 7 NEW RAISED ROOF AT ENTRY, REFERENCE NEW WORK PLANS

PROPOSED EXTERIOR LIGHT FIXTURE, REFERENCE EXTERIOR LIGHTING PLAN FOR MORE INFORMATION. LIGHT FIXTURES MUST BE DOWN LIT OR SHIELDED TO PREVENT GLARE. TOP OF FIXTURE TO BE OPAQUE.
8 9 NEW HORIZONTAL SIDING
10 NEW BAY WINDOW
NEW SELF CLOSING WOOD GATE WITH SELF-LATCHING MECHANISM. REFER TO SITE PLAN FOR HEIGHT 11

EXTERIOR

ELEVATIONS
13 A 1/4" = 1'-0"

EXISTING NORTH ELEVATION
B 1/4" = 1'-0"

PROPOSED NORTH ELEVATION
C 1/4" = 1'-0"

EXISTING GARAGE ELEVATION
D 1/4" = 1'-0"

PROPOSED GARAGE ELEVATION
129

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
12 3"
⅊ ⅊
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB
7'-1"
S.Y.S.B.
4'-4"
S.Y.S.B.

T.O. MAIN LEVEL F.F.
197'-3"
T.O. BASEMENT F.F.
188'-7"
T.O. RAILING
3'-6" A.F.S.
6 7
8 8 9
10 T.O. UPPER CURB
206'-0"
T.O. ROOF
215'-9"
T.O. ROOF
210'-6" 21'-9
3 4
" 3'-4" 7'-8" CEILING HEIGHT
T.O. BASEMENT F.F.
188'-7"
T.O. MAIN LEVEL F.F.
197'-3"

EXISTING

GARAGE BEYOND
STAIRS
BEYOND
⅊ ⅊
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB
7'-1"
S.Y.S.B.
4'-4"
S.Y.S.B.

T.O. MAIN LEVEL F.F.
197'-3"
T.O. BASEMENT F.F.
188'-7"
2 2
4 3 3 3
3 3
T.O. UPPER CURB
206'-0"
T.O. CHIMNEY
209-3"
T.O. ROOF
215'-9"

EXISTING
GARAGE BEYOND 7'-8" CEILING HEIGHT

ELEVATION KEYNOTES
EXISTING ROOFING TO BE REPLACED WITH CLASS 'A' STANDING SEAM METAL ROOF.

PROVIDE GUTTERS AND DOWNSPOUTS TIED INTO EXISTING DRAINAGE SYSTEM

EXISTING ROOF TO BE REPLACED WITH NEW ENTRY ROOF
1 2
3 4
5 6

EXISTING STAIR TO BE REPLACED, REFERENCE NEW WORK PLANS

EXISTING WINDOWS / DOOR TO BE REMOVED, REFERENCE NEW WORK PLANS FOR

REVISED OPENING

EXISTING CHIMNEY TO BE REMOVED

CUT OPENING FOR NEW DOOR OR WINDOW, REFERENCE NEW WORK PLANS 7 NEW RAISED ROOF AT ENTRY, REFERENCE NEW WORK PLANS

PROPOSED EXTERIOR LIGHT FIXTURE, REFERENCE EXTERIOR LIGHTING PLAN FOR MORE INFORMATION. LIGHT FIXTURES MUST BE DOWN LIT OR SHIELDED TO PREVENT GLARE. TOP OF FIXTURE TO BE OPAQUE.
8 9 NEW HORIZONTAL SIDING
10 NEW BAY WINDOW
NEW SELF CLOSING WOOD GATE WITH SELF-LATCHING MECHANISM. REFER TO SITE PLAN FOR HEIGHT 11

EXTERIOR

ELEVATIONS
14 B 1/4" = 1'-0"

PROPOSED SOUTH ELEVATION
A 1/4" = 1'-0"

EXISTING SOUTH ELEVATION

SOUND ATTENUATION FOR NEW AC COMPRESSOR,
REFERENCE PROPOSED SITE PLAN ON SHEET 2
C

SOUND ATTENUATION
D

AC UNIT MANUFACTURER SPECIFICATIONS
130

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110 9'-0"
T.O. GARAGE F.F.
206-3" 8'-8"
T.O. BASEMENT F.F.
188'-7"
T.O. MAIN LEVEL F.F.
197'-3" ⅊
10'-0"
F.Y.S.B. 30' BUILDING

ENVELOPE ABOVE
EXISTING GRADE 2 5 3 3 4 4 1 4
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB
5'-0"

REDUCED
GARAGE F.Y.S.B.EXISTING HEIGHT ABOVE CURB 9'-8"
T.O. UPPER CURB
206'-0"
40'-0" 13'-0"

EXISTING GRADE

EXISTING RETAINING
WALLS
FLOOR LINE BEYOND HEIGHT ABOVE GRADE EXISTING HEIGHT ABOVE GRADE 18'-2" 20'-2" EXISTING HEIGHT ABOVE CURB 9'-8" T.O. RAILING
3'-6" A.F.S. 9'-0"
T.O. GARAGE F.F.
206-3" 8'-8"
T.O. BASEMENT F.F.
188'-7"
T.O. MAIN LEVEL F.F.
197'-3"
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB ⅊
10'-0"
30' BUILDING

ENVELOPE ABOVE
EXISTING GRADE 6 7 9

EXISTING GRADE
5'-0"

REDUCED
GARAGE F.Y.S.B.

T.O. UPPER CURB
206'-0" 13'-0"
F.Y.S.B. 15'-0"
T.O. ROOF
210'-6"

STAIR LANDING AT

EXISTING GRADE

EXISTING RETAINING
WALLS
40'-0"
NEW 6'Ø PRE-FABRICATED,

FREESTANDING, SELF
CONTAINED JACUZZI.

EXISTING
RETAINING WALLS 30'-0"

FLOOR LINE BEYOND
17" HIGH STEP / SEAT
AROUND 6' Ø JACUZZI

ELEVATION KEYNOTES
EXISTING ROOFING TO BE REPLACED WITH CLASS 'A' STANDING SEAM METAL ROOF.

PROVIDE GUTTERS AND DOWNSPOUTS TIED INTO EXISTING DRAINAGE SYSTEM EXISTING ROOF TO BE REPLACED WITH NEW ENTRY ROOF 123456

EXISTING STAIR TO BE REPLACED, REFERENCE NEW WORK PLANS

EXISTING WINDOWS / DOOR TO BE REMOVED, REFERENCE NEW WORK PLANS FOR

REVISED OPENING

EXISTING CHIMNEY TO BE REMOVED
CUT OPENING FOR NEW DOOR OR WINDOW, REFERENCE NEW WORK PLANS 7 NEW RAISED ROOF AT ENTRY, REFERENCE NEW WORK PLANS

PROPOSED EXTERIOR LIGHT FIXTURE, REFERENCE EXTERIOR LIGHTING PLAN FOR MORE INFORMATION. LIGHT FIXTURES MUST BE DOWN LIT OR SHIELDED TO PREVENT GLARE. TOP OF FIXTURE TO BE OPAQUE. 89 NEW HORIZONTAL SIDING 10 NEW BAY WINDOW
NEW SELF CLOSING WOOD GATE WITH SELF-LATCHING MECHANISM. REFER TO SITE PLAN FOR HEIGHT 11

EXTERIOR

ELEVATIONS
15 B 1/4" = 1'-0"
PROPOSED WEST ELEVATION A 1/4" = 1'-0"

EXISTING WEST ELEVATION
131

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
⅊
10'-0"
F.Y.S.B. 30' BUILDING

ENVELOPE ABOVE

EXISTING GRADE
T.O. MAIN LEVEL F.F.
197'-3"
T.O. BASEMENT F.F.
188'-7"
2 5
3 3
4 4 3 1

EXISTING GRADE
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB
5'-0"

REDUCED
GARAGE F.Y.S.B.

T.O. UPPER CURB
206'-0" 7'-8" CEILING HEIGHT
20'-0" R.Y.S.B.

T.O. CHIMNEY
209-3" 16'-1
1 2
" 12'-0"

FLOOR LINE BEYOND
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB ⅊
10'-0"
F.Y.S.B. 30' BUILDING

ENVELOPE ABOVE

EXISTING GRADE
T.O. MAIN LEVEL F.F.
197'-3"
T.O. BASEMENT F.F.
188'-7"
T.O. RAILING
3'-6" A.F.S.
6 7
9 10

EXISTING GRADE
5'-0"

REDUCED
GARAGE F.Y.S.B.

T.O. UPPER CURB
206'-0" 7'-8" CEILING HEIGHT
T.O. ROOF
210'-6" 15'-0" 3'-4" 14'-9" 13'-9
1 2
"
20'-0" R.Y.S.B. 30'-0"

STAIR TREADS
BEYOND

NEW STAIRS

FLOOR LINE BEYOND

ELEVATION KEYNOTES
EXISTING ROOFING TO BE REPLACED WITH CLASS 'A' STANDING SEAM METAL ROOF.

PROVIDE GUTTERS AND DOWNSPOUTS TIED INTO EXISTING DRAINAGE SYSTEM

EXISTING ROOF TO BE REPLACED WITH NEW ENTRY ROOF
1 2
3 4
5 6

EXISTING STAIR TO BE REPLACED, REFERENCE NEW WORK PLANS

EXISTING WINDOWS / DOOR TO BE REMOVED, REFERENCE NEW WORK PLANS FOR

REVISED OPENING

EXISTING CHIMNEY TO BE REMOVED

CUT OPENING FOR NEW DOOR OR WINDOW, REFERENCE NEW WORK PLANS 7 NEW RAISED ROOF AT ENTRY, REFERENCE NEW WORK PLANS

PROPOSED EXTERIOR LIGHT FIXTURE, REFERENCE EXTERIOR LIGHTING PLAN FOR MORE INFORMATION. LIGHT FIXTURES MUST BE DOWN LIT OR SHIELDED TO PREVENT GLARE. TOP OF FIXTURE TO BE OPAQUE.
8 9 NEW HORIZONTAL SIDING
10 NEW BAY WINDOW
NEW SELF CLOSING WOOD GATE WITH SELF-LATCHING MECHANISM. REFER TO SITE

PLAN FOR HEIGHT
11 EXTERIOR

ELEVATIONS
16 B 1/4" = 1'-0"

PROPOSED EAST ELEVATION
A 1/4" = 1'-0"

EXISTING EAST ELEVATION
132

ZONING SUBMITTAL
DELTA 1 01.20.2022
DELTA 2 04.27.2022
DELTA 3 08.22.2022

08.05.2021
DAVID B. FRITH
349 THIRD STREET
LAGUNA BEACH, CA 92651
949.376.3080

AINA & GORDON MCBEAN

MCBEAN RESIDENCE
31421 HOLLY DR
LAGUNA BEACH, CA 92651
PROJECT:

CLIENT:

PROFESSIONAL SEAL:

ARCHITECT OF RECORD:

SIGNATURE DATE

SUBMISSION DATE
SCALE: AS NOTED
PROJECT NO: 21110
MASTER

BEDROOM

POWDER ENTRY
BEDROOM 1

EXISTING

GARAGE TO REMAIN

EXISTING ROOF

TO REMAIN

EXISTING ROOF

TO REMAIN

NEW ROOF AT
ENTRY
NEW STAIR 9'-0"
T.O. EXISTING GARAGE F.F.
206-3" 8'-8"
T.O. EXISTING BASEMENT F.F.
188'-7"
T.O. EXISTING MAIN LEVEL F.F.
197'-3"
⅊
10'-0"
F.Y.S.B. 30' BUILDING

ENVELOPE ABOVE

EXISTING GRADE

EXISTING GRADE
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB
5'-0"

REDUCED
GARAGE F.Y.S.B.

LINE OF EXISTING

ROOF TO BE REMOVED
T.O. UPPER CURB
206'-0"
40'-0" 13'-0" 7'-8" CEILING HEIGHT 8'-0" CEILING HEIGHT T.O. ROOF
210'-6" 17'-2" 28'-0"

EXISTING RETAINING
WALLS 30'-0" 30'-0"

MASTER ENTRY PANTRY KITCHEN

BATHROOM
12 3"
⅊ ⅊
15' MAXIMUM BUILDING HEIGHT ABOVE UPPER CURB
7'-1"
S.Y.S.B.
4'-4"
S.Y.S.B.

NEW 6'-0" HIGH

WOOD FENCE

EXISTING ROOF

TO REMAIN

NEW ROOF AT
ENTRY 10'-0"
T.O. EXISTING MAIN LEVEL F.F.
197'-3"
T.O. PLATE
207'-3" (10'-0" A.F.F.)
T.O. RIDGE
210'-6" (13'-3" A.F.F.) LINE OF EXISTING
ROOF TO BE REMOVED 13'-2
1 4
" T.O. UPPER CURB
206'-0" 15'-0"

BUILDING SECTIONS
17 B 1/4" = 1'-0"

BUILDING SECTION
A 1/4" = 1'-0"

BUILDING SECTION
133
Board of Adjustment/Design Review Board - 9 - February 23, 2023

4.4. 31421 HOLLY DRIVE (MCBEAN), APN 056-061-16 APPROVED DESIGN REVIEW 22-2245, VARIANCE 22-2266, AND CATEGORICAL EXEMPTION [Section 15301 and 15331].

City Staff: Kevin Parker, Associate Planner (949) 497-0632 [email protected] Project Applicant: Dave Frith, Architect (949) 376-3080 | [email protected] The applicant requests design review for a 760 square foot addition (first level: 351 SF; second level: 409 SF) to an existing 1,875 square foot single-family residence within the R-1 zone. The request includes the removal of an existing chimney, a new 300 square foot second-level rear balcony, new doors/windows, a new bay window, a new above ground spa, a 340 square foot remodel that includes the conversion of a bedroom into a new master bathroom, new metal roofing, new AC unit, and replacement of siding. The applicant requests a variance to construct the proposed addition without adding an additional covered parking space or without expanding the existing, legal nonconforming 279 square foot, one-car garage into a two-car garage (LBMC Section

25.56.008(C)).

Disclosures: Ms. Neev and Ms. Thalman and Ms. Gannon visited the site with Mr. Frith and spoke to Ms. Austin.

Staff Presentation: Associate Planner, Kevin Parker, summarized the staff report.

Project Representative: Architect, Dave Frith, presented the project.

Public Testimony: Mr. Austin stated his biggest concern was the newly proposed windows and its negative effects on his privacy. He requested the side panels of the window be frosted.

Ms. Austin explained how the pop-out windows were an invasion of their privacy.

Rebuttal: Mr. Frith believed each homeowner had their own responsibility to privacy and the owners were not willing to remove the proposed bay windows.

Board Questions: Ms. Thalman confirmed with Mr. Frith they would be amendable to an obscure glass only if necessary.

Board Comments: Ms. Neev did not believe the bay window caused privacy issue and believed the deck would have been more of a concern over the proposed window. She supported the variance and staff’s findings.

Ms. Gannon agreed with Ms. Neev and understood how the windows were going to be a reduction in size. She did not believe there was a privacy concern and agreed with the variance findings. Ms. Gannon commended Mr. Parker’s staff report and supported staff’s findings.

Ms. Thalman stated her colleagues did not believe a privacy issue existed and clarified she was wishing for a compromise between the neighbors but did not believe it would be achievable. She supported staff’s findings for the proposed variance and supported Attachment 10
134
Board of Adjustment/Design Review Board - 10 - February 23, 2023 the proposed project.

Ms. Gannon made a motion, seconded by Ms. Thalman, to approve Design Review 22- 2245 and Variance 22-2266 at 31421 Holly Drive with the findings as outlined in the staff report, and to adopt the categorical exemption pursuant to state CEQA. The motion carried, 3-0. Mr. Sheridan and Mr. Weil were absent.

Motion JG Second KT Action APPROVED
Gannon __Y__ Sheridan _ABSENT_ Thalman ___Y___ Neev ___Y___ Weil _ABSENT_

5. STAFF AND BOARD REPORTS

6. ADJOURNMENT
Adjournment at 7:03 p.m. to the regularly scheduled virtual Design Review Board on March 9, 2023, at 5:00 p.m.
135
From: Michael A <[email protected]>
Sent: Wednesday, February 22, 2023 2:36 PM
To: Parker, Kevin CD <[email protected]>; [email protected] Cc: [email protected]
Subject: DR 2022-2245 and variance 2022-2266
[NOTICE:  This message originated outside of City of Laguna Beach -- DO NOT CLICK on links or open attachments unless you are sure the content is safe.] Hi Kevin , I guess we are supposed to notify you and zoning administrator that we have some matters that we would like to discuss at the public hearing. These matters are currenting being discussed with the applicant's architect but I guess there is a deadline of 3 PM today, so we needed to get these in. my cell is 949-280-3501 if you need to reach me
Also we did email the Dr board members per the protocol Kevin here is the list we gave you february 16.

The issues are
Hvac placement and noise-- architect states he will show arrow pointing to the HVAC equipment symbol, vs the dimension and remove the 5' note portion since the distance is already shown. 2 of the 3 sets of Pop out windows
Window privacy concerns, design review guidelines call for placement and not maximizing windows next to neighbors , but no mention of window expansion in the staff report privacy section There is no detail on these windows, we have asked architect for this- this is pending as this has not been provided to us.

The fence has no detail
Will there be pool equipment or is all self contained…I guess this is resolved since its self contained The plans do not reflect our correct address.

These are our main concerns.

Your letter requested our concerns be in writing but it doesn’t go into what the next steps are.

Can you call me to discuss these concerns and what are the next steps.

Thank you
Attachment 11
136

CITY COUNCIL ORDER OF TESTIMONY FOR APPEALS

AND REQUESTS FOR REVIEW OF PROJECTS
Purpose: The City Council is committed to assuring that members of the public have the opportunity to speak to any meeting agenda item before final action on projects. This Order of Testimony establishes the right of persons who specifically wish to speak on projects appealed to or otherwise reviewed by the City Council.

Procedures: There are three types of hearings conducted by the City Council: 1) the appellant is person opposed to the project, 2) the appellant is the applicant, and 3) the project was called up for review by a member of the City Council or the City Manager. The procedures below provide the order in which testimony is considered and the allotted time for public comment. The procedure for each hearing shall be provided as the first attachment to the agenda bill.

I. Appellant is Person Opposed to Approved Project:

1. Staff report summary provided.

2. The appellant has 5 minutes for opening remarks.

3. Any persons in support of the appeal may speak for 3 minutes each.

4. The applicant has 5 minutes to speak in opposition to the appeal.

5. Any other persons in opposition to the appeal may speak for 3 minutes each.

6. The appellant has 2 minutes to speak in rebuttal.

Attachment 13
138

STAFF REPORT
Meeting Date:

December 9, 2025
APPEAL
C
SUBJECT: APPEAL OF DESIGN REVIEW BOARD APPROVAL OF DESIGN REVIEW 24- 2113 FOR MODIFICATIONS TO A PREVIOUSLY APPROVED LANDSCAPE PLAN FOR AN EXISTING SINGLE-FAMILY DWELLING AT 1813 TEMPLE HILLS DRIVE LOCATED IN THE R-1, RESIDENTIAL LOW-DENSITY ZONE,

AND CATEGORICAL EXEMPTION UNDER THE CALIFORNIA
ENVIRONMENTAL QUALITY ACT GUIDELINES SECTION 15304 (CLASS 4) RECOMMENDATION: It is recommended that the City Council:

1. Open the public hearing, take public testimony, and continue the public hearing to the January 6, 2026 City Council special meeting; and

2. Find the action is not a project within the meaning of the California Environmental Quality Act under Public Resources Code Section 21065.

SUMMARY OF THE MATTER
On February 13, 2025, the Design Review Board conditionally approved Design Review 24-1151 for modifications to a previously approved landscape plan associated with an existing single-family dwelling at 1813 Temple Hills Drive. On April 3, 2025, an appeal was filed by Rhett and Sherry Schiffman.

To continue the public hearing on the appeal without re-sending public hearing notices, staff requests that the City Council open the public hearing and continue the matter to a date certain. Staff does not intend to provide a report at this time. The project was previously continued from the October 28, 2025 City Council meeting, then to the November 18, 2025 City Council meeting, and later to this December 9, 2025 City Council meeting.

The sole purpose of this item is for City Council to take action on the requested continuance. Staff requests the City Council continue this public hearing to the January 6, 2026, City Council special meeting, beginning at 3:30 p.m.

FINANCIAL ANALYSIS
The recommended action has no financial impact to the budget.

ENVIRONMENTAL ANALYSIS
APPEAL OF THE APPROVAL OF DR 24-2113 AT 1813 TEMPLE HILLS DRIVE December 9, 2025

Page 2 of 2 ends

In accordance with the California Environmental Quality Act (CEQA), a project means an activity which may cause either a direct physical change in the environment, or a reasonably foreseeable indirect physical change in the environment, and which is any of the following: (a) an activity directly undertaken by a public agency; (b) an activity undertaken by a person which is supported, in whole or in part, through contracts, grants, subsidies, loans, or other forms of assistance from one or more public agencies; and ( c) an activity that involves the issuance to a person of a lease, permit, license, certificate, or other entitlement for use by one or more public agencies. (Public Resources Code Section 21065.) Here, the recommended actions, which result in a continuance of a public hearing, do not constitute a project because the public hearing continuance is not an activity which may cause either a direct physical change in the environment, or a reasonably foreseeable indirect physical change in the environment. It is an activity which instead results in the City Council considering an appeal of a project at a future date and does not authorize any development under a permit.

ATTACHMENTS
None
Submitted By: Matthew Scheider Approved: .David A Kiff
Matthew Schneider, Director of
Community Development
Dave Kiff, City Manager
Report Prepared By: Coordinated With:

Anthony Viera, Deputy Director of Community
Development

← All documents from this meeting