WHEREAS, the Ontario Plan 2050 Supplemental Environmental Impact Report (State Clearinghouse No. 2021070364) was certified on August 16, 2022 (hereinafter referred to as "Certified EIR"), in which development and use of the Project site was discussed; and
WHEREAS, the Planning Director of the City of Ontario prepared and approved for attachment to the certified Environmental Impact Report, an Addendum to the Certified EIR (hereinafter referred to as "EIR Addendum") in accordance with the requirements of the California Environmental Quality Act of 1970, together with State and local guidelines implementing said Act, all as amended to date (collectively referred to as "CEQA"); and WHEREAS, the environmental impacts of this Project were thoroughly analyzed in the EIR Addendum, which concluded that implementation of the Project could result in a number of significant effects on the environment that were previously analyzed in the Certified EIR, and that the Certified EIR identified mitigation measures that would reduce each of those significant effects to a less-than-significant level; and WHEREAS, the City's "Local Guidelines for the Implementation of the California Environmental Quality Act (CEQA)" provide for the use of a single environmental assessment in situations where the impacts of subsequent projects are adequately analyzed; and
WHEREAS, the Application is a project pursuant to the California Environmental Quality Act — Public Resources Code Section 21000 et seq. — (hereinafter referred to as "CEQA") and an EIR Addendum has been prepared to determine possible environmental impacts; and
WHEREAS, Ontario Development Code Table 2.02-1 (Review Matrix) grants the Planning Commission the responsibility and authority to review and make recommendation to the City Council on the subject Application; and WHEREAS, the Project has been reviewed for consistency with the Housing Element of the Policy Plan component of The Ontario Plan 2050, as State Housing Element law (as prescribed in Government Code Sections 65580 through 65589.8) requires that development projects must be consistent with the Housing Element, if upon consideration of all its aspects, it is found to further the purposes, principals, goals, and policies of the Housing Element; and
WHEREAS, the Project is located within the Airport Influence Area of Ontario International Airport, which encompasses lands within parts of San Bernardino, Riverside, and Los Angeles Counties, and is subject to, and must be consistent with, the policies and criteria set forth in the Ontario International Airport Land Use Compatibility Plan (hereinafter referred to as "ALUCP"), which applies only to jurisdictions within San 6104
Planning Commission Resolution
File No. PDEV23-039
February 25, 2025
Bernardino County, and addresses the noise, safety, airspace protection, and overflight impacts of current and future airport activity; and
WHEREAS, City of Ontario Development Code Division 2.03 (Public Hearings) prescribes the manner in which public notification shall be provided and hearing procedures to be followed, and all such notifications and procedures have been completed; and
WHEREAS, on February 19, 2025, the Development Advisory Board of the City of Ontario conducted a hearing to consider the Addendum and the Project, and concluded said hearing on that date, voting to issue Decision No. DAB25-004, recommending that the Planning Commission approve the Application; and
WHEREAS, as the first action on the Project, on February 25, 2025, the Planning Commission issued a Resolution recommending the City Council adopt the EIR Addendum, finding that the proposed Project introduces no new significant environmental impacts and applying all previously adopted mitigation measures to the Project, which were incorporated by reference; and
WHEREAS, on February 25, 2025, the Planning Commission of the City of Ontario conducted a hearing to consider the Project, and concluded said hearing on that date; and
WHEREAS, all legal prerequisites to the adoption of this Resolution have occurred.
NOW, THEREFORE, IT IS HEREBY FOUND, DETERMINED, AND RESOLVED by the Planning Commission of the City of Ontario, as follows:
SECTION 1: Environmental Determination and Findings. As the recommending body for the Project, the Planning Commission has reviewed and considered the information contained in the Addendum, the initial study, and the administrative record for the Project, including all written and oral evidence provided during the comment period. Based upon the facts and information contained in the Addendum, the initial study, and the administrative record, including all written and oral evidence presented to the Planning Commission, the Planning Commission finds as follows:
(1) The environmental impacts of this Project were reviewed in conjunction with an Addendum to TOP 2050 Supplemental Environmental Impact Report (State Clearinghouse No. 2021070364), certified by the Ontario City Council on August 16, 2022, in conjunction with File No. PGPA20-002; and
6105
Planning Commission Resolution
File No. PDEV23-039
February 25, 2025
(2) The EIR Addendum and administrative record have been completed in compliance with CEQA, the State CEQA Guidelines, and the City of Ontario Local CEQA Guidelines; and
(3) The City's "Guidelines for the Implementation of the California Environmental Quality Act (CEQA)" provide for the use of a single environmental assessment in situations where the impacts of subsequent projects are adequately analyzed. This Application introduces no new significant environmental impacts; and (4) All previously adopted mitigation measures shall be a condition of Project approval, as they are applicable to the Project, and are incorporated herein by this reference; and
(5) The EIR Addendum contains a complete and accurate reporting of the environmental impacts associated with the Project, and reflects the independent judgment of the Planning Commission; and
(6) There is no substantial evidence in the administrative record supporting a fair argument that the Project may result in significant environmental impacts.
SECTION 2: Subsequent or Supplemental Environmental Review Not Required. Based on the EIR Addendum, all related information presented to the Planning Commission, and the specific findings set forth in Section 1, above, the Planning Commission finds that the preparation of a subsequent or supplemental Certified EIR is not required for the Project, as the Project:
(1) Does not constitute substantial changes to the Certified EIR that will require major revisions to the Certified EIR due to the involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects; and
(2) Does not constitute substantial changes with respect to the circumstances under which the Certified EIR was prepared, that will require major revisions to the Certified EIR due to the involvement of new significant environmental effects or a substantial increase in the severity of the previously identified significant effects; and (3) Does not contain new information of substantial importance that was not known and could not have been known with the exercise of reasonable diligence at the time the Certified EIR was certified/adopted, that shows any of the following:
(a) The Project will have one or more significant effects not discussed in the Certified EIR; or
6106
Planning Commission Resolution
File No. PDEV23-039
February 25, 2025
(b) Significant effects previously examined will be substantially more severe than shown in the Certified EIR; or
(c) Mitigation measures or alternatives previously found not to be feasible would in fact be feasible and would substantially reduce one or more significant effects of the Project, but the City declined to adopt such measures; or (d) Mitigation measures or alternatives considerably different from those analyzed in the Certified EIR would substantially reduce one or more significant effects on the environment, but which the City declined to adopt.
SECTION 3: Housing Element Compliance. Pursuant to the requirements of California Government Code Chapter 3, Article 10.6, commencing with Section 65580, as the recommending body for the Project, the Planning Commission finds that based upon the facts and information contained in the Application and supporting documentation, at the time of Project implementation, the Project is consistent with the Housing Element of the Policy Plan (General Plan) component of The Ontario Plan 2050, as the Project site is not one of the properties in the Housing Element Sites Inventory contained in Tables B-1 and B-2 of the Housing Element Technical Report.
SECTION 4: Airport Land Use Compatibility Plan ("ALUCP") Compliance.
The California State Aeronautics Act (Public Utilities Code Section 21670 et seq.) requires that an Airport Land Use Compatibility Plan be prepared for all public use airports in the State; and requires that local land use plans and individual development proposals must be consistent with the policies set forth in the adopted Airport Land Use Compatibility Plan.
(1) On April 19, 2011, the City Council of the City of Ontario approved and adopted the Ontario International Airport Land use Compatibility Plan, establishing the Airport Influence Area for Ontario International Airport, which encompasses lands within parts of San Bernardino, Riverside, and Los Angeles Counties, and limits future land uses and development within the Airport Influence Area, as they relate to noise, safety, airspace protection, and overflight impacts of current and future airport activity. As the recommending body for the Project, the Planning Commission has reviewed and considered the facts and information contained in the Application and supporting documentation against the ONT ALUCP compatibility factors, including [1] Safety Criteria (ONT ALUCP Table 2-2) and Safety Zones (ONT ALUCP Map 2-2), [2] Noise Criteria (ONT ALUCP Table 2-3) and Noise Impact Zones (ONT ALUCP Map 2-3), [3] Airspace protection Zones (ONT ALUCP Map 2-4), and [4] Overflight Notification Zones (ONT ALUCP Map 2-5). As a result, the Planning Commission therefore finds and determines that the Project, when implemented in conjunction with the conditions of approval, will be consistent with the policies and criteria set forth within the ONT ALUCP; and 6107
Planning Commission Resolution
File No. PDEV23-039
February 25, 2025
SECTION 5: Concluding Facts and Reasons. Based upon the substantial evidence presented to the Planning Commission during the above-referenced hearing, and upon the specific findings set forth in the Sections above, the Planning Commission hereby concludes as follows:
(1) The proposed development at the proposed location is consistent with the goals, policies, plans and exhibits of the Vision, Policy Plan (General Plan), and City Council Priorities components of The Ontario Plan 2050. The proposed Project is located within the Mixed Use - Multimodal (MU-Multimodal land use district of the Policy Plan Land Use Map, and the proposed - PA1 (Hospitality Mixed-Use) of the Empire Groves Specific Plan. The development standards and conditions under which the proposed Project will be constructed and maintained is consistent with the goals, policies, plans, and exhibits of the Vision, Policy Plan (General Plan), and City Council Priorities components of The Ontario Plan.
(2) The proposed development is compatible with those on adjoining sites in relation to location of buildings, with particular attention to privacy, views, any physical constraint identified on the site and the characteristics of the area in which the site is located. The Project has been designed consistent with the requirements of the City of Ontario Development Code and the proposed - PA1 (Hospitality Mixed-Use) of the Empire Groves Specific Plan, including standards relative to the particular land use proposed (hotel/commercial), as-well-as building intensity, building and parking setbacks, building height, number of off-street parking and loading spaces, on-site and off-site landscaping, and fences, walls and obstructions. (3) The proposed development will complement and/or improve upon the quality of existing development in the vicinity of the Project and the minimum safeguards necessary to protect the public health, safety and general welfare have been required of the proposed Project. The Planning Commission has required certain safeguards, and imposed certain conditions of approval, which have been established to ensure that: [i] the purposes of the proposed Empire Groves Specific Plan are maintained; [ii] the project will not endanger the public health, safety or general welfare; [iii] the project will not result in any significant environmental impacts; [iv] the project will be in harmony with the area in which it is located; and [v] the project will be in full conformity with the Vision, City Council Priorities and Policy Plan components of The Ontario Plan, and the proposed Empire Groves Specific Plan.
(4) The proposed development is consistent with the development standards and design guidelines set forth in the Development Code, or applicable specific plan or planned unit development. The proposed Project has been reviewed for consistency with the general development standards and guidelines of the proposed Empire Groves Specific Plan that are applicable to the proposed Project, including building intensity, building and parking setbacks, building height, amount of off-street 6108
Planning Commission Resolution
File No. PDEV23-039
February 25, 2025
parking and loading spaces, parking lot dimensions, design and landscaping, bicycle parking, on-site landscaping, and fences and walls, as-well-as those development standards and guidelines specifically related to the particular land use being proposed (hotel/commercial). As a result of this review, the Planning Commission has determined that the Project, when implemented in conjunction with the conditions of approval, will be consistent with the development standards and guidelines described in the proposed Empire Groves Specific Plan.
SECTION 6: Planning Commission Action. Based upon the findings and conclusions set forth in the Sections above, the Planning Commission hereby RECOMMENDS THE CITY COUNCIL APPROVES the herein described Application, subject to each and every condition set forth in the Department reports attached hereto as "Attachment A," and incorporated herein by this reference.
SECTION 7: Indemnification. The Applicant shall agree to defend, indemnify and hold harmless, the City of Ontario or its agents, officers, and employees from any claim, action or proceeding against the City of Ontario or its agents, officers or employees to attack, set aside, void, or annul this approval. The City of Ontario shall promptly notify the Applicant of any such claim, action, or proceeding, and the City of Ontario shall cooperate fully in the defense.
SECTION 8: Custodian of Records. The documents and materials that constitute the record of proceedings on which these findings have been based are located at the City of Ontario City Hall, 303 East "B" Street, Ontario, California 91764. The custodian for these records is the City Clerk of the City of Ontario.
SECTION 9: Certification to Adoption. The Secretary shall certify to the adoption of the Resolution.
- - - - - - - - - - - - - -
6109
6110
6111
Planning Commission Resolution
File No. PDEV23-039
February 25, 2025
ATTACHMENT A:
File No. PDEV23-039
Departmental Conditions of Approval
(Departmental conditions of approval to follow this page) 6112
6113
6114
6115
6116
6117
6118
6119
6120
6121
6122
6123
6124
6125
6126
6127
6128
6129
6130
6131
6132
6133
6134
6135
6136
AIRPORT LAND USE COMPATIBILITY PLANNING
ĔēĘĎĘęĊēĈĞĊęĊėĒĎēĆęĎĔēĊĕĔėę
Project File No.:
Address:
APN:
Existing Land
Use:
Proposed Land
Use:
Site Acreage:
ONT-IAC Project Review:
$LUSRUW,QÀXHQFH$UHD
This proposed Project is: Exempt from the ALUCP Consistent Consistent with Conditions Inconsistent Reviewed By:
Date:
Contact Info:
Project Planner:
CD No.:
PALU No.:
The project is impacted by the following ONT ALUCP Compatibility Zones:
Safety Noise Impact Airspace Protection 2YHUÀLJKW1RWL¿FDWLRQ Zone 1
Zone 1A
Zone 2
Zone 3
Zone 4
Zone 5
75+ dB CNEL
70 - 75 dB CNEL
65 - 70 dB CNEL
60 - 65 dB CNEL
High Terrain Zone
)$$1RWL¿FDWLRQ6XUIDFHV
Avigation Easement
Dedication
5HFRUGHG2YHUÀLJKW
1RWL¿FDWLRQ
Real Estate Transaction
'LVFORVXUH
Zone 1 Zone 2 Zone 3 Zone 4 Zone 5
$LUSRUW3ODQQHU6LJQDWXUH
CONSISTENCY DETERMINATION
3URSRVHG6WUXFWXUH+HLJKW
Airspace Avigation
Easement Area
Allowable
Height:
$LUVSDFH2EVWUXFWLRQ
6XUIDFHV
The project is impacted by the following Chino ALUCP Safety Zones:
Zone 6
Allowable Height:
PSP23-001, PDEV23-039, PDA23-005
southeast corner of Guasti Road and Holt Boulevard
110-322-33
Vacant lot
Specific Plan, Development Plan to construct a 600,000 square foot hotel and commercial building
10.43 n/a
ONT
The proposed project is located within the Airport Influence Area of Ontario International Airport (ONT) and was evaluated and found to be consistent with the policies and criteria of the Airport Land Use Compatibility Plan (ALUCP) for ONT.
See Attached conditions.
✔
✔
✔
✔
✔
Lorena Mejia
909-395-2276
Lorena Mejia
2/12/2025
2023-024
24-002
120 FT
120 -140 FT
✔
6137
CD No.:
PALU No.:
PROJECT CONDITIONS
AIRPORT LAND USE COMPATIBILITY PLANNING
ĔēĘĎĘęĊēĈĞĊęĊėĒĎēĆęĎĔēĊĕĔėę
1. The project site is located within an area where 120-140 foot building heights are allowed. The applicant will be required to file for an FAA Obstruction Evaluation/Airport Airspace Analysis (FAA Form 7460-1) and receive a Determination of No Hazard prior to building permit issuance.
2. The project site is located within an area where 120-140 foot building heights are allowed. The applicant will be required to file for an FAA Obstruction Evaluation/Airport Airspace Analysis (FAA Form 7460-1) for any temporary construction equipment such as cranes and receive a Determination of No Hazard for any temporary structures/objects that are over 100 feet in height.
24-002
2023-024
6138
CITY OF ONTARIO
MEMORANDUM
TO: Lorena Mejia, Senior Planner
Planning Department
FROM: Robert Johnson, Deputy Fire Chief
Fire Department
DATE: February 12, 2025
SUBJECT: PDEV23-039 - A Development Plan to construct a 9-story hotel consisting of approximately 596.450 square feet to include 600 rooms, ancillary retail and various amenities on 10.43 acres of land located at 2236 East Holt Boulevard, within the SP (Specific Plan) zoning district and the MTC (Multimodal Transit Center) overlay (APN(s): 0110-322-33). Related File(s): PSP-23-001; PDA-23-005.
The plan does adequately address Fire Department requirements at this time Standard Conditions of Approval apply, as stated below.
See attached access exhibit
SITE AND BUILDING FEATURES:
A. 2022 CBC Type of Construction: Not listed, assumed I-A B. Type of Roof Materials: N/A
C. Ground Floor Area(s): N/A
D. Number of Stories: 9
E. Total Square Footage: 598,441 Sq. Ft.
F. 2022 CBC Occupancy Classification(s): R-1
6139
2 of 5
CONDITIONS OF APPROVAL:
1.0 GENERAL
1.1 The following are the Ontario Fire Department (“Fire Department”) requirements for this development project, based on the current edition of the California Fire Code (CFC), and the current versions of the Fire Prevention Standards (“Standards.”) It is recommended that the applicant or developer transmit a copy of these requirements to the on-site contractor(s) and that all questions or concerns be directed to the Bureau of Fire Prevention, at (909) 395-2029.
For copies of Ontario Fire Department Standards please access the City of Ontario web site at www.ontarioca.gov/Fire/Prevention.
1.2 These Fire Department conditions of approval are to be included on any and all construction drawings.
2.0 FIRE DEPARTMENT ACCESS
2.1 Fire Department vehicle access roadways shall be provided to within one hundred and fifty feet (150’) of all portions of the exterior walls of the first story of any building, unless specifically approved. Roadways shall be paved with an all-weather surface and shall be a minimum of twenty-four (24) ft. wide. See Standard #B-004.
2.2 In order to allow for adequate turning radius for emergency fire apparatus, all turns shall be designed to meet the minimum twenty-five feet (25’) inside and forty-five feet (45’) outside turning radius per Standard #B-005.
2.3 Fire Department access roadways that exceed one hundred and fifty feet (150’) in length shall have an approved turn-around per Standard #B-002.
2.4 Access drive aisles which cross property lines shall be provided with CC&Rs, access easements, or reciprocating agreements, and shall be recorded on the titles of affected properties, and copies of same shall be provided at the time of building plan check.
2.5 "No Parking-Fire Lane" signs and /or red painted curbs with lettering are required to be installed in interior access roadways, in locations where vehicle parking would obstruct the minimum clear width requirement. Installation shall be per Standard #B-001.
2.6 Security gates or other barriers on fire access roadways shall be provided with a Knox brand key switch or padlock to allow Fire Department access. See Standards #B-003, B-004 and H001. 6140
3 of 5
2.7 Any time PRIOR to on-site combustible construction and/or storage, a minimum twenty-four feet (24’) wide circulating all weather access roads shall be provided to within one hundred and fifty feet (150’) of all portions of the exterior walls of the first story of any building, unless specifically approved by fire department and other emergency services.
3.0 WATER SUPPLY
3.1 The required fire flow per Fire Department standards, based on the 2022 California Fire Code, Appendix B, is 3000 gallons per minute (g.p.m.) for 4 hours at a minimum of 20 pounds per square inch (p.s.i.) residual operating pressure.
3.2 Off-site (public) fire hydrants are required to be installed on all frontage streets, at a maximum spacing of three hundred feet (300’) apart, on alternating sides of the street. Streets with a center median shall require public hydrants spaced five hundred feet (500’) apart, on the same side of the street.
3.3 Buildings that exceed 100,000 square feet in floor area shall provide an onsite looped fire protection water line around the building(s.) The loops shall be required to have two or more points of connection from a public circulating water main.
3.4 The water supply, including water mains and fire hydrants, shall be tested and approved by the Engineering Department and Fire Department prior to combustible construction to assure availability and reliability for firefighting purposes.
4.0 FIRE PROTECTION SYSTEMS
4.1 On-site private fire hydrants are required per Standard #D-005, and identified in accordance with Standard #D-002. Installation and locations(s) are subject to the approval of the Fire Department. An application with detailed plans shall be submitted, and a construction permit shall be issued by the Fire Department, prior to any work being done.
4.2 Underground fire mains which cross property lines shall be provided with CC & R, easements, or reciprocating agreements, and shall be recorded on the titles of affected properties, and copies of same shall be provided at the time of fire department plan check. The shared use of private fire mains or fire pumps is allowable only between immediately adjacent properties and shall not cross any public street.
4.3 An automatic fire sprinkler system is required. The system design shall be in accordance with National Fire Protection Association (NFPA) Standard 13. All new fire sprinkler systems, except those in single family dwellings, which contain twenty (20) sprinkler heads or more shall be monitored by an approved listed supervising station. An application along with detailed plans shall be submitted, and a construction permit shall be issued by the Fire Department, prior to any work being done.
6141
4 of 5
4.4 Wood frame buildings that are to be sprinkled shall have these systems in service (but not necessarily finaled) before the building is enclosed.
4.5 Fire Department Connections (FDC) shall be located on the address side of the building within one hundred fifty feet (150’) of a public fire hydrant on the same side of the street. Provide identification for all fire sprinkler control valves and fire department connections per Standard #D-007. Raised curbs adjacent to Fire Department connection(s) shall be painted red, five feet either side, per City standards.
4.6 A fire alarm system is required. The system design shall be in accordance with National Fire Protection Association (NFPA) Standard 72. An application along with detailed plans shall be submitted, and a construction permit shall be issued by the Fire Department, prior to any work being done.
4.7 Portable fire extinguishers are required to be installed prior to occupancy per Standard #C-001.
Please contact the Fire Prevention Bureau to determine the exact number, type and placement required.
4.8 A fixed fire extinguishing system is required for the protection of hood, duct, plenum and cooking surfaces. This system must comply with National Fire Protection Association (NFPA) Standards 17A and 96. An application with detailed plans shall be submitted, and a construction permit shall be issued by the Fire Department, prior to any work being done.
4.9 Provide a Fire Command Center in accordance with the Fire Code Section 508.1 in all buildings classified as high-rise buildings by the California Building Code and Group I-2 occupancies having occupied floors located more than 75 feet (23 m) above the lowest level of fire department vehicle access and in all F-1 and S-1 occupancies with a building footprint greater than 500,000 square feet
5.0 BUILDING CONSTRUCTION FEATURES
5.1 The developer/general contractor is to be responsible for reasonable periodic cleanup of the development during construction to avoid hazardous accumulations of combustible trash and debris both on and off the site.
5.2 Approved numbers or addresses shall be placed on all new and existing buildings in such a position as to be plainly visible and legible from the street or road fronting the property. Multitenant or building projects shall have addresses and/or suite numbers provided on the rear of the building. Address numbers shall contrast with their background. See Section 9-1 6.06 of the Ontario Municipal Code and Standards #H-003 and #H-002.
5.6 Knox ® brand key-box(es) shall be installed in location(s) acceptable to the Fire Department.
All Knox boxes shall be monitored for tamper by the building fire alarm system. See Standard #H-001 for specific requirements.
6142
5 of 5
6.0 OTHER SPECIAL USES
6.1 The storage, use, dispensing, or handling of any hazardous materials shall be approved by the Fire Department, and adequate fire protection features shall be required. If hazardous materials are proposed, a Fire Department Hazardous Materials Information Packet, including Disclosure Form and Information Worksheet, shall be completed and submitted with Material Safety Data Sheets to the Fire Department along with building construction plans.
6.3 Underground fuel tanks, their associated piping and dispensers shall be reviewed, approved, and permitted by Ontario Building Department, Ontario Fire Department, and San Bernardino County Fire Department Hazardous Materials Division. In fueling facilities, an exterior emergency pump shut-off switch shall be provided.
6143
\
\
/
/
/
\
\
/
\
\
GENERAL NOTES
1 'NO PARKING-FIRE LANE' SIGNS AND /OR RED
• PAINTED CURBS WITH LETTERING ARE
REQUIRED TO BE INSTALLED IN INTERIOR
ACCESS ROMJWAYS, IN LOCATIONS WHERE
VEHICLE PARKING WOULD OBSTRUCT THE
#B-001.
I
I
I
I
FIRE ACCESS SITE PLAN
SCALE: 1132'= 1'-0'
I I I I
BALl:.ROOM
30 FT
Bldg. Height
' ' \
\
\
\
\
I
I
I
I
I
I
I
\
\
I
I
I
I
I
I
I
\
\
I
I O ffon A· SB County Flood Control
1 1 fire Acc~ss. Provide a mit~~~ :::
wide paved area, setbac
; building between the proposed
/ southern wall to the north rooftop
stair access as shown. This Option
requires San Bernardino County
approval.
I
\
I
I
I
I
I
I
I
l
I
I
\
THE EMPIRE
GROVES HOTEL
Ontario CA 91730
Gensler
500SoulhFigueroastreet
LosAngeles,CatilomIa90071
UniledStates
I 6. Date D11crlpHon
Tel 213.327.3600
Fax213.327.3601
9129123 ISSUEFORENTITLEMENT
1 7112124 REISSUE FOR ENTITLEMENT
2 1212/2024 REISSUE FOR ENTITLEMENT
I Seal/Sign, ture
NOTFOR
CONSTRUCTION
I ProJeetName
Diversified Pacific
Communities
I Project Number
05.4382.000
I Dascrtpllon
FIRE ACCESS PLAN
Seale
As indicated
AS.002
©2015Gensler
6144
CITY OF ONTARIO
LANDSCAPE PLANNING DIVISION
303 East “B” Street, Ontario, CA 91764
CONDITIONS OF APPROVAL
Sign Off
01/28/2025
Jamie Richardson, Sr. Landscape Architect Date
Reviewer’s Name:
Jamie Richardson, Sr. Landscape Architect
Phone:
(909) 395-2615
D.A.B. File No.:
PDEV23-039, PDA-23-005, PSP-23-001
Case Planner:
Lorena Mejia
Project Name and Location:
9-Story, 600 Room Hotel
2236 East Holt Blvd
Applicant/Representative:
Diversified Pacific Development Group, LLC Nolan Leggio [email protected] 10621 Civic Center Drive
Rancho Cucamonga, CA 91730
Preliminary Plans (dated 12/12/2024) meet the Standard Conditions for New Development and have been approved considering that the following conditions below be met upon submittal of the landscape construction documents.
Preliminary Plans (dated) have not been approved. Corrections noted below are required before Preliminary Landscape Plan approval.
A RESPONSE SHEET IS REQUIRED WITH RESUBMITTAL OR PLANS WILL BE RETURNED AS INCOMPLETE.
DIGITAL SUBMITTALS MUST BE 10MB OR LESS.
Civil/ Site Plans
1. Mitigation for removed trees shall equal the trunk diameter of heritage trees removed per the Development Code Tree Preservation Policy and Protection Measures, section 6.05.020. A total of 795.5 inches of trunk replacement is required; see below for mitigation options.
2. Show on demo plans and landscape construction plans trees to be preserved, removed or mitigation measures for trees removed, such as:
a. New 15 gallon trees min 1” diameter trunk, in addition to trees required. b. New 24” box trees min 1.5” diameter trunk, in addition to trees required. c. Upsizing trees on the plan one size larger such as 15 gallon to 24” box, or 24” to 36” box size.
d. Monetary value of the trees removed as identified in the “Guide for Plant Appraisal,” approved certified arborist plant appraiser, may be equal to the value of the installation cost of planting, fertilizing, staking, and irrigating 15-gallon trees (100$ each) to the City of Ontario Historic Preservation Fund for city tree planting or city approved combination of the above items.
3. Include improvements to the Cucamonga Flood Control Channel.
4. Before permit issuance, stormwater infiltration devices located in landscape areas shall be reviewed and plans approved by the Landscape Planning Division. Any stormwater devices in parkway areas shall not displace street trees.
5. Stormwater chamber systems shall be designed and configured to allow for required tree locations.
6. Show transformers set back 5’ from paving all sides. Coordinate with landscape plans. Note that if SCE requires bollards (less than 5’ setback from vehicular paving), permanent, decorative bollards will be required; submit cut shets to the Planning Department. 6145
7. Show all backflow devices set back 4’ from paving on all sides. Locate on level grade
8. Locate utilities including light standards, fire hydrants, water, drain, and sewer lines to not conflict with required tree locations—coordinate civil plans with landscape plans.
9. Provide a utility clear space 8’ wide in parkways and 30’ apart for street trees. Move water meters, drain lines, and light standards to the utility minimum spacing and show utility lines at the edges of the parkway, toward the driveway apron, to allow space for street trees.
Landscape Plans
10. Shrub and Ground Cover Palette: Replace Dendromecon and Mimulus are easily overwatered, Isomeris (large and rangy, OK with ample planter areas), Ericameria (invasive), Lavandula (short-lived), Pennisetum/Nassella (invasive) and limit the use of non-invasive ornamental grasses to accent areas (difficult and costly to maintain in masses and poor winter appearance).
11. Show backflow devices with 36” high strappy leaf shrub screening and trash enclosures and transformers, a 4’-5’ high evergreen hedge screening. Do not encircle utility; show as masses and duplicate masses in other locations at regular intervals.
12. Locate light standards, fire hydrants, water, and sewer lines to not conflict with required tree locations. Coordinate civil plans with landscape plans
13. Show all utilities on the landscape plans. Coordinate so utilities are clear of tree locations.
14. Landscape construction plans shall meet the requirements of the Landscape Development Guidelines. See http://www.ontarioca.gov/landscape-planning/standards
15. After a project’s entitlement approval, the applicant shall pay all applicable fees for landscape plan check and inspections at a rate established by resolution of the City Council.
Specific Plan Comments
16. Shrub and Ground Cover Palette: Replace Dendromecon and Mimulus are easily overwatered, Isomeris (large and rangy, OK with ample planter areas), Ericameria (invasive), Lavandula (short-lived), Pennisetum/Nassella (invasive) and limit the use of non-invasive ornamental grasses to accent areas (difficult and costly to maintain in masses and poor winter appearance).
6146
(NOTE: Standard Conditions of Approval are attached.) Form Revised: 12/12/23
PROJECT REVIEW BOARD COMMENTS
* * * BUILDING DEPARTMENT * * *
Planning Case File No(s): PDEV23-039
Case Planner: Lorena Mejia
Applicant: Ontario Project LLC – Gabriel Guerreo
Location: 2236 Holt
Project:
A Development Plan to construct a 9-story hotel consisting of approximately 596.450 square feet to include 600 rooms, ancillary retail and various amenities on
10.43 acres of land located at 2236 East Holt Boulevard, within the SP (Specific Plan) zoning district and the MTC (Multimodal Transit Center) overlay (APN(s):
0110-322-33). Related File(s): PSP-23-001; PDA-23-005.
APN(s): 0110-322-33
Reviewed By: Klaus De Guzman Date: 1/13/2025
Following Standard Building Department Conditions of Approval Are Applicable to This Project:
See checked boxes below
Specific Conditions:
A)
Specific Comments (NOTE: THESE COMMENTS ARE NOT CONDITIONS!):
A)
6147
BUILDING DEPARTMENT
GENERAL CONDITIONS
☒ 1. Shall comply with the latest adopted edition of the following codes as applicable:
A. California Building Code
B. California Residential Code
C. California Existing Building Code
D. California Electrical Code
E. California Mechanical Code
F. California Plumbing Code
G. California Energy Code.
H. California Fire Code
I. California Green Building Standards Code.
☐ 2. The property owner/business operator shall comply with all applicable City of Ontario Municipal Codes and Ordinances.
☒ 3. The requirements of the Department of Environmental Health Services and the Air Quality Management District shall be satisfied prior to the issuance of any permit if hazardous materials are stored and/or used.
☒ 4. Pursuant to the California Business and Professions Code Section 6737, most projects are required to be designed by a California Licensed Architect or Engineer. The project owner or developer should review the section of the California Codes and comply with the regulation ☐ 5. All perimeter / boundary walls shall be designed and constructed so that the outer/exterior face of the wall is as close as possible to the lot line. In any case, the outer/exterior face of the wall shall be within two (2) inches of the lot line. Distances greater than two (2) inches may be approved prior to construction by the Building Official on a case-by-case basis for extenuating circumstances.
☐ 6. All lot lines, easement lines, etc. shall be located and/or relocated in such a manner as to not cause any existing structure to become non-conforming with the requirements of the latest adopted edition of the Building Code, or any other applicable law, ordinance, or code. ☒ 7. The Developer/Owner is responsible for the coordination of the final occupancy. The Developer/Owner shall obtain clearances from each department and division prior to requesting a final building inspection from the Building Department. Each department shall sign the Building Department Job Card
☒ 8. All signs shall be Underwriters Laboratories, or equal, approved. 6148
☐ 9. Permits are required prior to the removal and/or demolition of structures. ☐ 10. In addition to approval from Building Department, approval is required from the County of San Bernardino, Department of Public Health and the California Regional Water Quality Control Board, Santa Ana Region for the Private Sewage Disposal System. ☐ 11. The existing private sewage system will have to be modified as required to accommodate the new use. Plans and/or supporting data will have to be submitted to, and approved by, the Building Department regarding the new use and necessary modifications. Additionally, approval from the Regional Water Quality Control Board, Santa Ana Region, is required for the new use.
☐ 12. The coach shall bear a State of California, Department of Housing and Community Development (HCD) insignia indicating the occupancy group and design loads that the coach conforms to, and other relevant information regarding exiting, fire safety, electrical, plumbing and mechanical. The foundation system, porch and awning shall comply with plans that bear the HCD “Standard Plan Approval” stamp. The coach, foundation system, porch and awning shall comply with the City of Ontario’s design loads and site-specific conditions. ☐ 13. The conversion of the existing single-family dwelling(s) into a commercial use changes the occupancy group classification, and therefore the existing buildings must be made to comply with the requirements of all applicable codes for the new occupancy classification. Complete plans, calculations and other specifications shall be submitted to the Building Department for review, approval and subsequent permit issuance. The plans, calculations and other specifications shall be prepared by an Architect or Registered Civil/Structural Engineer licensed by the State of California who is qualified to perform said work. ☐ 14. The site, or a portion of the site, is in a flood hazard area. Justification that the proposed development does not adversely affect the location or carrying capacity of the floodway, nor does it adversely affect upstream or downstream sites shall be provided to Building Department. Additionally, all provisions must be taken to protect the site from flood damage. ☐ 15. All exterior lighting shall be orientated, directed, and/or shielded as much as possible so that direct illumination does not infringe onto adjoining properties. ☒ 16. Site facilities such as parking open or covered, recreation facilities, and trash dumpster areas, and common use areas shall be accessible per the CBC, Chapter 11. ☒ 17. Trash Enclosure shall be covered, and the interior clearances shall be designed to accommodate the following:
4’ min. side access entrance
6149
3’ min. wide clear pathway along rear of enclosure between trash bins and back wall. Trash bins must be oriented sideways to allow access from the narrow dimension. Use of curbs or wheel stops shall be provided within the enclosure to maintain access clearances and bin orientations.
☒ 18. The applicant/developer shall include the conditions of approval of this resolution on the construction plans.
☒ 19. Site development and grading shall be designed to provide access to all entrances and exterior ground floors exits and access to normal paths of travel, and where necessary to provide access. Paths of travel shall incorporate (but not limited to) exterior stairs, landings, walks and sidewalks, pedestrian ramps, curb ramps, warning curbs, detectable warning, signage, gates, lifts and walking surface materials. The accessible route(s) of travel shall be the most practical direct route between accessible building entrances, site facilities, accessible parking, public sidewalks, and the accessible entrance(s) to the site, California Building Code, (CBC) Chapter 11, Sec, 11A and 11B.
☐ 20. Commercial/Industrial gated site must have at least one pedestrian emergency gate, 3’-0’ x 6’-8” min. gate size, equipped with panel hardware on the inside, and gate must swing out.
Pedestrian emergency gates can be installed integrated with vehicular gates. ☐ 21. New residential single-family dwelling (SFD’s):
The side yard gate must swing out toward the street.
The gas meter shall not obstruct side yard access gates. Air Conditioning unit located at side yard shall maintain 3’ min. clearance from property line wall to AC unit.
Provide a continuous concrete walk between garage side door to driveway or sidewalk. ☐ 22. New development projects located in the Ontario Ranch specific plan are required to submit a methane assessment report. This report shall be submitted to the Building Department for review and approval at grading plan submittal.
☐ 23. If hazardous substances are used and/or stored, a technical opinion and report, identifying and developing methods of protection from the hazards presented by the hazardous materials may be required. This report shall be prepared by a qualified person, firm, or corporation and submitted to Building Department. This report shall also explain the proposed facility's intended methods of operation and list all of the proposed materials, their quantities, classifications, and the effects of any chemical (material) intermixing in the event of an accident or spill.
☒ 24. The property owner/business operator shall provide a grease interceptor at a location where it shall be easily accessible for inspection, cleaning, and removal of accumulated grease.
The sizing and installation shall conform to the current California Plumbing Code. The grease interceptor shall be constructed in accordance with plans approved by the Director of Public 6150
Works and the Building Official. The property owner/business operator shall contract with a maintenance company for maintenance and cleaning of the grease interceptor.
SITE CONSTRUCTION REQUIRMENTS
☒ 25. All construction sites must be protected by a security fence and screening. The fencing and screening shall always maintained to protect pedestrians ☒ 26. Temporary toilet facilities shall be provided for construction workers. The toilet facilities shall be maintained in a sanitary condition. Construction toilet facilities of the non-sewer type shall conform to ANSI ZA.3
☒ 27. Construction projects which require temporary electrical power shall obtain an Electrical Permit from Building Department. No temporary electrical power will be granted to a project unless one of the following items is in place and approved by Building Department and the Planning Department.
(A) Installation of a construction trailer, or
(B) Security fenced area where the electrical power will be located ☒ 28. Installation of construction/sales trailers must be located on private property. No trailers can be in the public street right of way
☒ 29. Any temporary building, trailer, commercial coach, etc. installed and/or used in connection with a construction project shall comply with City Code. ☐ 30. Prior to issuance of a Building Permit all of the following must be in place: portable toilet with hand wash station, all BMP's, fencing and signage on each adjacent street saying "If there is any dust or debris coming from this site please contact (superintendent number here) or the AQMD if the problem is not being resolved" or something similar to this.
PRIOR TO ISSUANCE OF BUILDING/CONSTRUCTION PERMITS
☒ 31. The following grading items shall be completed and/or submitted – as applicable – prior to the issuance of building permits for this project:
A. Precise grading plans shall be approved
B. Rough grading completed
C. Compaction certification completed
D. Pad elevation certification completed
E. Rough grade inspection signed off by a City’s Building Inspector ☒ 32. Prior to the issuance of a Building Permit, the applicant shall pay all Development 6151
Improvement Fees to the City. Copies of receipts shall be provided to the Building Department prior to permit issuance.
☒ 33. The Tract or Parcel map shall record prior to the issuance of any permits. ☐ 34. The existing parcels shall be combined into a single parcel, or a lot line adjustment shall be done so that the proposed structure(s) does not cross any lot line and complies with all requirements of the California Building Code, prior to any building permits being issued. ☐ 35. Fire sprinklers, fire alarm systems and fire hydrant plans shall be submitted for plan review concurrently with building plans and shall be approved prior to permit issuance ☒ 36. Prior to issuance of Building Permits, school fees need to be paid to school district where project is located
6152
(NOTE: Standard Conditions of Approval are attached.) Form Revised: 12/12/23
PROJECT REVIEW BOARD COMMENTS
* * * BUILDING DEPARTMENT * * *
Planning Case File No(s): PDEV23-039
Case Planner: Lorena Mejia
Applicant: Ontario Project LLC – Gabriel Guerreo
Location: 2236 Holt
Project:
A Development Plan to construct a 9-story hotel consisting of approximately 596.450 square feet to include 600 rooms, ancillary retail and various amenities on
10.43 acres of land located at 2236 East Holt Boulevard, within the SP (Specific Plan) zoning district and the MTC (Multimodal Transit Center) overlay (APN(s):
0110-322-33). Related File(s): PSP-23-001; PDA-23-005.
APN(s): 0110-322-33
Reviewed By: Klaus De Guzman Date: 1/13/2025
Following Standard Building Department Conditions of Approval Are Applicable to This Project:
See checked boxes below
Specific Conditions:
A)
Specific Comments (NOTE: THESE COMMENTS ARE NOT CONDITIONS!):
A)
6153
BUILDING DEPARTMENT
GENERAL CONDITIONS
☒ 1. Shall comply with the latest adopted edition of the following codes as applicable:
A. California Building Code
B. California Residential Code
C. California Existing Building Code
D. California Electrical Code
E. California Mechanical Code
F. California Plumbing Code
G. California Energy Code.
H. California Fire Code
I. California Green Building Standards Code.
☐ 2. The property owner/business operator shall comply with all applicable City of Ontario Municipal Codes and Ordinances.
☒ 3. The requirements of the Department of Environmental Health Services and the Air Quality Management District shall be satisfied prior to the issuance of any permit if hazardous materials are stored and/or used.
☒ 4. Pursuant to the California Business and Professions Code Section 6737, most projects are required to be designed by a California Licensed Architect or Engineer. The project owner or developer should review the section of the California Codes and comply with the regulation ☐ 5. All perimeter / boundary walls shall be designed and constructed so that the outer/exterior face of the wall is as close as possible to the lot line. In any case, the outer/exterior face of the wall shall be within two (2) inches of the lot line. Distances greater than two (2) inches may be approved prior to construction by the Building Official on a case-by-case basis for extenuating circumstances.
☐ 6. All lot lines, easement lines, etc. shall be located and/or relocated in such a manner as to not cause any existing structure to become non-conforming with the requirements of the latest adopted edition of the Building Code, or any other applicable law, ordinance, or code. ☒ 7. The Developer/Owner is responsible for the coordination of the final occupancy. The Developer/Owner shall obtain clearances from each department and division prior to requesting a final building inspection from the Building Department. Each department shall sign the Building Department Job Card
☒ 8. All signs shall be Underwriters Laboratories, or equal, approved. 6154
☐ 9. Permits are required prior to the removal and/or demolition of structures. ☐ 10. In addition to approval from Building Department, approval is required from the County of San Bernardino, Department of Public Health and the California Regional Water Quality Control Board, Santa Ana Region for the Private Sewage Disposal System. ☐ 11. The existing private sewage system will have to be modified as required to accommodate the new use. Plans and/or supporting data will have to be submitted to, and approved by, the Building Department regarding the new use and necessary modifications. Additionally, approval from the Regional Water Quality Control Board, Santa Ana Region, is required for the new use.
☐ 12. The coach shall bear a State of California, Department of Housing and Community Development (HCD) insignia indicating the occupancy group and design loads that the coach conforms to, and other relevant information regarding exiting, fire safety, electrical, plumbing and mechanical. The foundation system, porch and awning shall comply with plans that bear the HCD “Standard Plan Approval” stamp. The coach, foundation system, porch and awning shall comply with the City of Ontario’s design loads and site-specific conditions. ☐ 13. The conversion of the existing single-family dwelling(s) into a commercial use changes the occupancy group classification, and therefore the existing buildings must be made to comply with the requirements of all applicable codes for the new occupancy classification. Complete plans, calculations and other specifications shall be submitted to the Building Department for review, approval and subsequent permit issuance. The plans, calculations and other specifications shall be prepared by an Architect or Registered Civil/Structural Engineer licensed by the State of California who is qualified to perform said work. ☐ 14. The site, or a portion of the site, is in a flood hazard area. Justification that the proposed development does not adversely affect the location or carrying capacity of the floodway, nor does it adversely affect upstream or downstream sites shall be provided to Building Department. Additionally, all provisions must be taken to protect the site from flood damage. ☐ 15. All exterior lighting shall be orientated, directed, and/or shielded as much as possible so that direct illumination does not infringe onto adjoining properties. ☒ 16. Site facilities such as parking open or covered, recreation facilities, and trash dumpster areas, and common use areas shall be accessible per the CBC, Chapter 11. ☒ 17. Trash Enclosure shall be covered, and the interior clearances shall be designed to accommodate the following:
• 4’ min. side access entrance
6155
• 3’ min. wide clear pathway along rear of enclosure between trash bins and back wall. • Trash bins must be oriented sideways to allow access from the narrow dimension. • Use of curbs or wheel stops shall be provided within the enclosure to maintain access clearances and bin orientations.
☒ 18. The applicant/developer shall include the conditions of approval of this resolution on the construction plans.
☒ 19. Site development and grading shall be designed to provide access to all entrances and exterior ground floors exits and access to normal paths of travel, and where necessary to provide access. Paths of travel shall incorporate (but not limited to) exterior stairs, landings, walks and sidewalks, pedestrian ramps, curb ramps, warning curbs, detectable warning, signage, gates, lifts and walking surface materials. The accessible route(s) of travel shall be the most practical direct route between accessible building entrances, site facilities, accessible parking, public sidewalks, and the accessible entrance(s) to the site, California Building Code, (CBC) Chapter 11, Sec, 11A and 11B.
☐ 20. Commercial/Industrial gated site must have at least one pedestrian emergency gate, 3’-0’ x 6’-8” min. gate size, equipped with panel hardware on the inside, and gate must swing out.
Pedestrian emergency gates can be installed integrated with vehicular gates. ☐ 21. New residential single-family dwelling (SFD’s):
• The side yard gate must swing out toward the street.
• The gas meter shall not obstruct side yard access gates. • Air Conditioning unit located at side yard shall maintain 3’ min. clearance from property line wall to AC unit.
• Provide a continuous concrete walk between garage side door to driveway or sidewalk. ☐ 22. New development projects located in the Ontario Ranch specific plan are required to submit a methane assessment report. This report shall be submitted to the Building Department for review and approval at grading plan submittal.
☐ 23. If hazardous substances are used and/or stored, a technical opinion and report, identifying and developing methods of protection from the hazards presented by the hazardous materials may be required. This report shall be prepared by a qualified person, firm, or corporation and submitted to Building Department. This report shall also explain the proposed facility's intended methods of operation and list all of the proposed materials, their quantities, classifications, and the effects of any chemical (material) intermixing in the event of an accident or spill.
☒ 24. The property owner/business operator shall provide a grease interceptor at a location where it shall be easily accessible for inspection, cleaning, and removal of accumulated grease.
The sizing and installation shall conform to the current California Plumbing Code. The grease interceptor shall be constructed in accordance with plans approved by the Director of Public 6156
Works and the Building Official. The property owner/business operator shall contract with a maintenance company for maintenance and cleaning of the grease interceptor.
SITE CONSTRUCTION REQUIRMENTS
☒ 25. All construction sites must be protected by a security fence and screening. The fencing and screening shall always maintained to protect pedestrians ☒ 26. Temporary toilet facilities shall be provided for construction workers. The toilet facilities shall be maintained in a sanitary condition. Construction toilet facilities of the non-sewer type shall conform to ANSI ZA.3
☒ 27. Construction projects which require temporary electrical power shall obtain an Electrical Permit from Building Department. No temporary electrical power will be granted to a project unless one of the following items is in place and approved by Building Department and the Planning Department.
(A) Installation of a construction trailer, or
(B) Security fenced area where the electrical power will be located ☒ 28. Installation of construction/sales trailers must be located on private property. No trailers can be in the public street right of way
☒ 29. Any temporary building, trailer, commercial coach, etc. installed and/or used in connection with a construction project shall comply with City Code. ☐ 30. Prior to issuance of a Building Permit all of the following must be in place: portable toilet with hand wash station, all BMP's, fencing and signage on each adjacent street saying "If there is any dust or debris coming from this site please contact (superintendent number here) or the AQMD if the problem is not being resolved" or something similar to this.
PRIOR TO ISSUANCE OF BUILDING/CONSTRUCTION PERMITS
☒ 31. The following grading items shall be completed and/or submitted – as applicable – prior to the issuance of building permits for this project:
A. Precise grading plans shall be approved
B. Rough grading completed
C. Compaction certification completed
D. Pad elevation certification completed
E. Rough grade inspection signed off by a City’s Building Inspector ☒ 32. Prior to the issuance of a Building Permit, the applicant shall pay all Development 6157
Improvement Fees to the City. Copies of receipts shall be provided to the Building Department prior to permit issuance.
☒ 33. The Tract or Parcel map shall record prior to the issuance of any permits. ☐ 34. The existing parcels shall be combined into a single parcel, or a lot line adjustment shall be done so that the proposed structure(s) does not cross any lot line and complies with all requirements of the California Building Code, prior to any building permits being issued. ☐ 35. Fire sprinklers, fire alarm systems and fire hydrant plans shall be submitted for plan review concurrently with building plans and shall be approved prior to permit issuance ☒ 36. Prior to issuance of Building Permits, school fees need to be paid to school district where project is located
6158