1. CALL TO ORDER
2. ROLL CALL
3. PLEDGE OF ALLEGIANCE
4. PRESENTATIONS/PROCLAMATIONS/ANNOUNCEMENTS
5. BLUE FOLDER ITEMS (SUPPLEMENTAL)
Blue folder (supplemental) items are additional back up materials to administrative reports, changes to the posted agenda packet, and/or public comments received after the printing and distribution of the agenda packet for receive and file.
5.A. FOR BLUE FOLDER DOCUMENTS APPROVED AT THE CITY COUNCIL
MEETING
RECOMMENDATION: Approved
6. PUBLIC COMMENT ON NON-AGENDA ITEMS
This is the appropriate time for members of the public to make comments regarding itemsnot listed on this agenda.
Pursuant to the Brown Act, no action will take place on any items not on the agenda.
7. CONSENT CALENDAR
Business items, except those formally noticed for public hearing, or those pulled for discussion are assigned to the Consent Calendar. The Mayor or any Councilmember may request that any Consent Calendar item(s) be removed, discussed, and acted upon separately. Items removed from the Consent Calendar will be taken up under the "Excluded Consent Calendar" section below. Those items remaining on the Consent Calendar will be approved in one motion. The Mayor will call on anyone wishing to address the City Council on any Consent Calendar item on the agenda, which has not been pulled by Councilmembers for discussion.
2 PORTUGUESE BEND ROAD
ROLLING HILLS, CA 90274
(310) 377-1521
AGENDA
Regular City Council Meeting
CITY COUNCIL
Monday, January 09, 2023
CITY OF ROLLING HILLS
7:00 PM
The meeting agenda is available on the City’s website. The City Council meeting will be live-streamed on the City’s website.
Both the agenda and the live-streamed video can be found here:
https://www.rolling-hills.org/government/agenda/index.php Members of the public may submit written comments in real-time by emailing the City Clerk’s office at [email protected].
Your comments will become part of the official meeting record. You must provide your full name, but please do not provide any other personal information that you do not want to be published.
Recordings to City Council meetings can be found here: https://www.rolling-hills.org/government/agenda/index.php Next Resolution No. 1323 Next Ordinance No. 383
CL_AGN_230109_CC_BlueFolderItem_11A.pdf
CL_AGN_230109_CC_BlueFolderItem_11B.pdf
1 7.A. APPROVE AFFIDAVIT OF POSTING FOR THE CITY COUNCIL REGULAR MEETING OF JANUARY 9, 2023
RECOMMENDATION: Approve.
7.B. APPROVE MOTION TO READ BY TITLE ONLY AND WAIVE FURTHER
READING OF ALL ORDINANCES AND RESOLUTIONS LISTED ON THE AGENDA
RECOMMENDATION: Approve.
7.C. APPROVE THE FOLLOWING CITY COUNCIL MINUTES: DECEMBER 13, 2022 RECOMMENDATION: Approve as presented.
7.D. PAYMENT OF BILLS.
RECOMMENDATION: Approve as presented.
7.E. APPROVE CITY COUNCIL MEETING DATES FOR CALENDAR YEAR 2023 RECOMMENDATION: Approve as presented.
7.F. APPROVE ANNUAL VENDOR LIST FOR CALENDAR YEAR 2023
RECOMMENDATION: Approve as presented.
7.G. APPROVE REPUBLIC SERVICES' 2023 CLEAN-UP AND COMMUNAL BIN
SCHEDULE
RECOMMENDATION: Approve as presented.
7.H. FOR SECOND READING AND ADOPTION: ADOPT BY TITLE ONLY ORDINANCE NO. 381 AMENDING CHAPTER 17.28 OF THE ROLLING HILLS
MUNICIPAL CODE REGARDING ACCESSORY DWELLING UNITS AND JUNIOR
ACCESSORY DWELLING UNITS AND DETERMINING THE ORDINANCES TO
BE EXEMPT FROM CEQA
RECOMMENDATION: Adopt by title only Ordinance No. 381, entitled, " AN
ORDINANCE OF THE CITY COUNCIL OF THE CITY OF ROLLING HILLS AMENDING CHAPTER 17.28 OF THE ROLLING HILLS MUNICIPAL CODE
REGARDING ACCESSORY DWELLING UNITS AND JUNIOR ACCESSORY
DWELLING UNITS AND DETERMINING THE ORDINANCE TO BE EXEMPT FROM CEQA."
7.I. FOR SECOND READING AND ADOPTION:Â ADOPT BY TITLE ONLY ORDINANCE NO. 382 AMENDING TITLE 15 (BUILDINGS AND
CONSTRUCTION) OF THE ROLLING HILLS MUNICIPAL CODE AND
DETERMINING THE ORDINANCE EXEMPT FROM CEQA
RECOMMENDATION: It is recommended that the City Council waive full reading and adopt Ordinance No. 382 amending Title 15 regarding Building CL_AGN_230109_CC_AffidavitofPosting.pdf
CL_MIN_221213_CC_F.pdf
CL_AGN_230109_CC_PaymentOfBills.pdf
CL_AGN_230109_CC_2023_MeetingDates.pdf
VC_230109_PreferredVendorList.pdf
Attachment 1 - CL_ORD_381_ADU Ordinance_D3.pdf
2 and Construction.
7.J. ADOPT RESOLUTION NO. 1321 OF THE CITY COUNCIL OF THE CITY OF
ROLLING HILLS AUTHORIZING SUBMITTAL OF APPLICATIONS FOR THE
CALIFORNIA DEPARTMENT OF RESOURCES RECYCLING AND RECOVERY (CALRECYCLE) PAYMENT PROGRAMS AND RELATED AUTHORIZATIONS RECOMMENDATION: Approve as presented.
8. EXCLUDED CONSENT CALENDAR ITEMS
9. COMMISSION ITEMS
10. PUBLIC HEARINGS
11. OLD BUSINESS
11.A. APPROVE PLANS AND SPECIFICATIONS AND AUTHORIZE SOLICITATION
FOR CONSTRUCTION BIDS FOR THE CITY HALL HEATING, VENTILATION
AND AIR CONDITIONING (HVAC) PROJECT AND FINDING THE SAME EXEMPT FROM THE CALIFORNIA ENVIRONMENTAL QUALITY ACT.
RECOMMENDATION: Approve as presented.
11.B. RECEIVE AND FILE AN UPDATE TO THE OUTDOOR SIREN PROJECT RECOMMENDATION:
Receive and file
12. NEW BUSINESS
12.A. PROPOSED FISCAL YEAR 2023/24 BUDGET CALENDAR
RECOMMENDATION: Review and approve the proposed budget calendar for the development of the fiscal year 2023/24 budget.
12.B. CONSIDER ENGAGING 4LEAF, INC. TO PROVIDE CODE ENFORCEMENT
SERVICES, AND DIRECT STAFF TO EXECUTE A PROFESSIONAL SERVICES AGREEMENT FOR AN AMOUNT NOT-TO-EXCEED $87,880 FOR ONE
ATTACHMENT 1 - CL_ORD_382_BuildingCodeOrdinance_D2.pdf
ResolutionNo1321_CalRecycleGrant.pdf
CL_AGN_230109_CC_HVAC_UpgradeCostEstimate.pdf
CL_AGN_230109_CC_HVAC_RepairSpecs.pdf
CL_AGN_230109_CC_HVAC_RepairDrawings.pdf
CL_AGN_230109_CC_HVAC_PublicComment01_Redacted.pdf
CL-AGN_230109_CC_22-12-21_SpecialNewsletter.pdf
CL-AGN_230109_CC_SBN Comments.pdf
CL_AGN_230109_CC_SIrenStudyUpdate_PublicComment01.pdf
CL_AGN_230109_CC_SIrenStudyUpdate_PublicComment02._Redacted.pdf CL_AGN_230109_CC_SIrenStudyUpdate_PublicComment03.pdf
CL_AGN_230109_CC_SIrenStudyUpdate_PublicComment04_Redacted.pdf CL_AGN_230109_CC_SIrenStudyUpdate_PublicComment05_Redacted.pdf FN_BUD_230109_Calendar_FY23-24.pdf
3 CALENDAR YEAR INCLUDING $68,380 FOR THE REMAINDER OF THE 2022- 2023 FISCAL YEAR
RECOMMENDATION: Direct the City Manager to execute a Professional Services Agreement with 4LEAF, Inc. for code enforcement services.
13. MATTERS FROM THE CITY COUNCIL
14. MATTERS FROM STAFF
14.A. FIRE FUEL ABATEMENT AND CODE ENFORCEMENT QUARTERLY REPORT FOR THE FOURTH QUARTER OF 2022 (OCTOBER 1 THROUGH DECEMBER 31)
RECOMMENDATION: Receive and file.
15. CLOSED SESSION
16. RECONVENE TO OPEN SESSION
17. ADJOURNMENT
Next regular meeting: Monday, January 23, 2023 at 7:00 p.m. in the City Council Chamber, Rolling Hills City Hall, 2 Portuguese Bend Road, Rolling Hills, California, 90274.
CA_AGR_4Leaf_On_Call_CE PSA-c1_DRAFT-c1.pdf
PL_CON_20221128_CE_4LEAF_SOQ_without_appendix.pdf
PL_CON_4LEAF_FeeSchedule22_23.pdf
CE_QRP_2022_Q4_Opened_Cases.pdf
CE_QRP_2022_Q4_Closed_Cases.pdf
CE_QRP_2022_Q4_Cumulative_Open_Cases.pdf
Notice:
Public Comment is welcome on any item prior to City Council action on the item.
Documents pertaining to an agenda item received after the posting of the agenda are available for review in the City Clerk's office or at the meeting at which the item will be considered.
In compliance with the Americans with Disabilities Act (ADA), if you need special assistance to participate in this meeting due to your disability, please contact the City Clerk at (310) 377-1521 at least 48 hours prior to the meeting to enable the City to make reasonable arrangements to ensure accessibility and accommodation for your review of this agenda and attendance at this meeting. 4 Agenda Item No.: 5.A
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: CHRISTIAN HORVATH, CITY CLERK / EXECUTIVE ASSISTANT TO
CITY MANAGER
THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: FOR BLUE FOLDER DOCUMENTS APPROVED AT THE CITY COUNCIL
MEETING
DATE: January 09, 2023
BACKGROUND:
None.
DISCUSSION:
None.
FISCAL IMPACT:
None.
RECOMMENDATION:
Approved.
ATTACHMENTS:
CL_AGN_230109_CC_BlueFolderItem_11A.pdf
CL_AGN_230109_CC_BlueFolderItem_11B.pdf
5 BLUE FOLDER ITEM (SUPPLEMENTAL)
Blue folder (supplemental) items are additional back up materials to administrative reports, changes to the posted agenda packet, and/or public comments received after the printing and distribution of the agenda packet for receive and file.
CITY COUNCIL MEETING
January 9, 2023
11.A APPROVE PLANS AND SPECIFICATIONS AND AUTHORIZE SOLICITATION FOR
CONSTRUCTION BIDS FOR THE CITY HALL HEATING, VENTILATION AND AIR
CONDITIONING (HVAC) PROJECT AND FINDING THE SAME EXEMPT FROM THE CALIFORNIA ENVIRONMENTAL QUALITY ACT.
FROM: CHRISTIAN HORVATH, CITY CLERK/EXECUTIVE ASSISTANT TO THE CITY
MANAGER
CL_AGN_230109_CC_HVAC_PublicComment01_Redacted.pdf
6 BLUE FOLDER ITEM (SUPPLEMENTAL)
Blue folder (supplemental) items are additional back up materials to administrative reports, changes to the posted agenda packet, and/or public comments received after the printing and distribution of the agenda packet for receive and file.
CITY COUNCIL MEETING
January 9, 2023
11.B RECEIVE AND FILE AN UPDATE TO THE OUTDOOR SIREN PROJECT FROM: CHRISTIAN HORVATH, CITY CLERK/EXECUTIVE ASSISTANT TO THE CITY
MANAGER
CL_AGN_230109_CC_SIrenStudyUpdate_PublicComment01.pdf
CL_AGN_230109_CC_SIrenStudyUpdate_PublicComment02_Redacted.pdf CL_AGN_230109_CC_SIrenStudyUpdate_PublicComment03.pdf
CL_AGN_230109_CC_SIrenStudyUpdate_PublicComment04_Redacted.pdf CL_AGN_230109_CC_SIrenStudyUpdate_PublicComment05_Redacted.pdf 7 Agenda Item No.: 7.A
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: CHRISTIAN HORVATH, CITY CLERK / EXECUTIVE ASSISTANT TO
CITY MANAGER
THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: APPROVE AFFIDAVIT OF POSTING FOR THE CITY COUNCIL REGULAR MEETING OF JANUARY 9, 2023
DATE: January 09, 2023
BACKGROUND:
None.
DISCUSSION:
None.
FISCAL IMPACT:
None.
RECOMMENDATION:
Approve.
ATTACHMENTS:
CL_AGN_230109_CC_AffidavitofPosting.pdf
8 Administrative Report
7.A., File # 1585 Meeting Date: 01/09/2023
To: MAYOR & CITY COUNCIL
From: Christian Horvath, City Clerk
TITLE
APPROVE AFFIDAVIT OF POSTING FOR THE CITY COUNCIL REGULAR MEETING OF JANUARY 9, 2023
EXECUTIVE SUMMARY
STATE OF CALIFORNIA )
COUNTY OF LOS ANGELES ) SS
CITY OF ROLLING HILLS )
AFFIDAVIT OF POSTING
In compliance with the Brown Act, the following materials have been posted at the locations below.
Legislative Body City Council
Posting Type Regular Meeting Agenda
Posting Location 2 Portuguese Bend Road, Rolling Hills, CA 90274 City Hall Window
City Website: https://www.rolling-hills.org/government/agenda/index.php https://www.rolling-hills.org/government/city_council/city_council_archive_agendas/index.php Meeting Date & Time January 9, 2023 7:00pm Open Session As City Clerk of the City of Rolling Hills, I declare under penalty of perjury, the document noted above was posted at the date displayed below.
Christian Horvath, City Clerk
Date: January 6, 2022
9 Agenda Item No.: 7.B
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: CHRISTIAN HORVATH, CITY CLERK / EXECUTIVE ASSISTANT TO
CITY MANAGER
THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: APPROVE MOTION TO READ BY TITLE ONLY AND WAIVE FURTHER
READING OF ALL ORDINANCES AND RESOLUTIONS LISTED ON THE AGENDA
DATE: January 09, 2023
BACKGROUND:
None.
DISCUSSION:
None.
FISCAL IMPACT:
None.
RECOMMENDATION:
Approve.
ATTACHMENTS:
10 Agenda Item No.: 7.C
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: CHRISTIAN HORVATH, CITY CLERK / EXECUTIVE ASSISTANT TO
CITY MANAGER
THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: APPROVE THE FOLLOWING CITY COUNCIL MINUTES: DECEMBER 13, 2022
DATE: January 09, 2023
BACKGROUND:
None.
DISCUSSION:
None.
FISCAL IMPACT:
None.
RECOMMENDATION:
Approve as presented.
ATTACHMENTS:
CL_MIN_221213_CC_F.pdf
11 MINUTES – CITY COUNCIL MEETING
Monday, December 13, 2022
Minutes
Rolling Hills City Council
Monday, December 13, 2022
Regular Meeting 7:00 p.m.
1. CALL TO ORDER
The City Council of the City of Rolling Hills met in person on the above date at 7:00 p.m. Mayor Black presiding.
2. ROLL CALL
Councilmembers Present: Dieringer, Pieper, Mirsch, Mayor Pro Tem Wilson, Mayor Black Councilmembers Absent: None
Staff Present: Elaine Jeng, City Manager
Michael Jenkins, City Attorney
John Signo, Planning & Community Services Director
Vanessa Hevener, Senior Management Analyst
3. PLEDGE OF ALLEGIANCE – Councilmember Dieringer
4. CERTIFICATION OF ELECTION / CITY COUNCIL REORGANIZATION / PRESENTATIONS /
PROCLAMATIONS
4.A. MAYOR'S PRESENTATION OF KEY TO THE CITY RECOGNIZING CITY ATTORNEY MICHAEL JENKINS FOR HIS 40 YEARS OF SERVICE TO THE CITY OF ROLLING HILLS Mayor Black presented the Key to the City and Recognition plaque to City Attorney Jenkins.
City Attorney Jenkins addressed the Council with personal remarks.
Public Comment: Gordana Swanson, Tony Dahlerbruch, City Manager Jeng
4.B. ADOPT BY TITLE ONLY RESOLUTION NO. 1317 RECITING THE FACT OF THE GENERAL MUNICIPAL ELECTION HELD ON TUESDAY, NOVEMBER 8, 2022, DECLARING THE RESULTS
AND SUCH MATTERS AS PROVIDED BY LAW
Presentation by Planning & Community Services Director Signo Motion by Councilmember Dieringer, seconded by Councilmember Pieper Adopt Resolution 1317 declaring the results of the General Municipal Election held on November 8, 2022 and taking such further actions as provided by law to complete the election process. Motion carried unanimously with the following vote:
AYES: Dieringer, Pieper, Mirsch, Wilson, Mayor Black
NOES: None
ABSENT: None
4.C. ADMINISTRATION OF OATH OF OFFICE BY CITY CLERK TO RE-ELECTED MAYOR JAMES BLACK, M.D.
4.D. ADMINISTRATION OF OATH OF OFFICE BY CITY CLERK TO RE-ELECTED MAYOR PRO TEM
PATRICK WILSON
12 MINUTES – CITY COUNCIL MEETING
Monday, December 13, 2022
4.E. ADMINISTRATION OF OATH OF OFFICE BY CITY CLERK TO RE-ELECTED COUNCILMEMBER
LEAH MIRSCH
City Manager Jeng administered the Oath of Office to all three re-elected officials at the same time.
4.F. CITY COUNCIL REORGANIZATION
Motion by Mayor Black, seconded by Councilmember Mirsch to nominate Mayor Pro Tem Wilson to serve as Mayor. Motion carried unanimously with the following vote:
AYES: Dieringer, Pieper, Mirsch, Wilson, Mayor Black
NOES: None
ABSENT: None
Mayor Wilson presented a Plaque of Recognition to former Mayor Black in appreciation for his service, as well as Certificates of Recognition from Assemblymember Muratsuchi, Supervisor Hahn, the City of Rolling Hills Estates, the City of Palos Verdes and the City of Rancho Palos Verdes.
Motion by Mayor Wilson, seconded by Councilmember Dieringer to nominate Councilmember Mirsch to serve as Mayor Pro Tem. Motion carried unanimously with the following vote:
AYES: Black, Dieringer, Pieper, Mirsch, Mayor Wilson
NOES: None
ABSENT: None
Mayor Wilson called for a brief recess at 7:46 p.m.
Mayor Wilson called the meeting back to order at 8:01 p.m.
5. BLUE FOLDER ITEMS (SUPPLEMENTAL) – NONE
6. PUBLIC COMMENT ON NON-AGENDA ITEMS – NONE
7. CONSENT CALENDAR
7.A. APPROVE AFFIDAVIT OF POSTING FOR THE CITY COUNCIL REGULAR MEETING OF DECEMBER 13, 2022
7.B. APPROVE MOTION TO READ BY TITLE ONLY AND WAIVE FURTHER READING OF ALL
ORDINANCES AND RESOLUTIONS LISTED ON THE AGENDA
7.C. APPROVE THE FOLLOWING CITY COUNCIL MINUTES: NOVEMBER 14, 2022
7.D. PAYMENT OF BILLS
7.E. REPUBLIC SERVICES RECYCLING TONNAGE REPORT FOR NOVEMBER 2022
7.F. PULLED BY MAYOR WILSON
7.G. PULLED BY COUNCILMEMBER DIERINGER
13 MINUTES – CITY COUNCIL MEETING
Monday, December 13, 2022
7.H. APPROVE A PROFESSIONAL SERVICES AGREEMENT WITH BENNETT LANDSCAPE TO
PROVIDE LANDSCAPING SERVICES FOR THE CITY HALL CAMPUS
7.I. APPROVE THE FIRST AMENDMENT TO PROFESSIONAL SERVICES AGREEMENT WITH WILLDAN FOR PHASE 2 OF THE SANITARY SEWER FEASIBILITY STUDY FOR A NOT-TOEXCEED FEE OF $9,010; ADOPT BY RESOLUTION NO. 1318 AUTHORIZING A BUDGET MODIFICATION OF $9,010.
7.J. PULLED BY COUNCILMEMBER DIERINGER
Motion by Councilmember Pieper, seconded by Councilmember Mirsch to approve Consent Calendar.
Motion carried unanimously with the following vote:
AYES: Black, Dieringer, Pieper, Mirsch, Mayor Wilson
NOES: None
ABSENT: None
8. EXCLUDED CONSENT CALENDAR ITEMS
7.F. RECEIVE AND FILE A LETTER FROM HCD INDICATING THE CITY'S 6TH CYCLE HOUSING
ELEMENT, ALONG WITH TECHNICAL MODIFICATIONS, IS IN FULL COMPLIANCE WITH
STATE LAW AND ACCEPT THE TECHNICAL MODIFICATIONS
Motion by Councilmember Mirsch, seconded by Councilmember Black to receive and file. Motion carried unanimously with the following vote:
AYES: Black, Dieringer, Pieper, Mirsch, Mayor Wilson
NOES: None
ABSENT: None
7.G. APPROVE A PROFESSIONAL SERVICES AGREEMENT WITH ONWARD ENGINEERING TO PROVIDE ON-CALL CONSTRUCTION OR GENERAL INSPECTION SERVICES DURING FY22/23 FOR A NOT-TO-EXCEED FEE OF $24,470; ADOPT BY RESOLUTION NO. 1319 AUTHORIZING A BUDGET MODIFICATION OF $24,470
Motion by Councilmember Pieper, seconded by Councilmember Black to Adopt by Resolution No. 1319 authorizing a budget modification of $24,470 and approve the professional service agreement as amended with the addition of the $135.00 hourly rate. Motion carried unanimously with the following vote:
AYES: Black, Dieringer, Pieper, Mirsch, Mayor Wilson
NOES: None
ABSENT: None
7.J. ACCEPT EMERGENCY STORM DRAIN REPAIR AT 3 MIDDLERIDGE LANE NORTH AS COMPLETE, FILE NOTICE OF COMPLETION, AND RELEASE RETENTION AFTER 30 DAY LIEN
PERIOD TO EC CONSTRUCTION
Motion by Councilmember Dieringer to have a letter from Onward Engineering regarding whatever they observed and their opinion as to the work done so the City Council has some information on which to base an acceptance of the project.
Motion failed for lack of a second.
14 MINUTES – CITY COUNCIL MEETING
Monday, December 13, 2022
Motion by Councilmember Mirsch to accept this item with the addition of the photographs to staff records, seconded by Councilmember Pieper. Motion carried with the following vote:
AYES: Black, Pieper, Mirsch, Mayor Wilson
NOES: Dieringer
ABSENT: None
9. COMMISSION ITEMS – NONE
10. PUBLIC HEARINGS
10.A. PUBLIC HEARING FOR INTRODUCTION AND FIRST READING OF ORDINANCE NO. 381 AND ADOPTION OF URGENCY ORDINANCE NO. 381-U AMENDING CHAPTER 17.28 OF THE
ROLLING HILLS MUNICIPAL CODE REGARDING ACCESSORY DWELLING UNITS AND
JUNIOR ACCESSORY DWELLING UNITS AND DETERMINING THE ORDINANCES TO BE
EXEMPT FROM CEQA
Presentation by Planning & Community Services Director Signo Motion by Councilmember Black, seconded by Councilmember Dieringer to find that the adoption of the ordinances is statutorily exempt from review under CEQA pursuant to Public Resources Code Section 21080.17; Introduce for first reading by title only Ordinance No. 381 regarding ADUs and JADUs; and Adopt Ordinance No. 381-U regarding ADUs and JADUs. Motion carried unanimously with the following vote:
AYES: Black, Dieringer, Pieper, Mirsch, Mayor Wilson
NOES: None
ABSENT: None
11. NEW BUSINESS
11.A. ADOPT RESOLUTION NO. 1320, A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF ROLLING HILLS APPOINTING PATRICK DONEGAN AS CITY ATTORNEY; AND AUTHORIZE
THE CITY MANAGER TO EXECUTE ANY DOCUMENTS NECESSARY TO IMPLEMENT THE
APPOINTMENT
Presentation by City Attorney Michael Jenkins
Motion by Councilmember Pieper, seconded by Councilmember Mirsch to approve as presented. Motion carried with the following vote:
AYES: Black, Dieringer, Pieper, Mirsch, Mayor Wilson
NOES: None
ABSENT: None
11.B. INTRODUCTION AND FIRST READING OF ORDINANCE NO. 382 AND ADOPTION OF URGENCY ORDINANCE NO. 382-U AMENDING TITLE 15 (BUILDINGS AND CONSTRUCTION)
OF THE ROLLING HILLS MUNICIPAL CODE AND DETERMINING THE ORDINANCE EXEMPT
FROM CEQA
Presentation by Planning & Community Services Director Signo 15 MINUTES – CITY COUNCIL MEETING
Monday, December 13, 2022
Motion by Councilmember Black, seconded by Councilmember Mirsch to find that the adoption of the ordinances is not a project subject to CEQA review because it has no potential for resulting in physical change to the environment; Introduce for first reading by title only Ordinance No. 382 regarding building and construction; and Adopt Ordinance No. 382-U regarding building and construction. Motion carried unanimously with the following vote:
AYES: Black, Dieringer, Pieper, Mirsch, Mayor Wilson
NOES: None
ABSENT: None
12. OLD BUSINESS
12.A. RECEIVE FEEDBACK FROM CALWATER, COUNTY OF LOS ANGELES FIRE DEPARTMENT,
AND PALOS VERDES PENINSULA UNIFIED SCHOOL DISTRICT ON THE OUTDOOR SIREN
PROJECT, AND APPROVE THE THIRD AMENDMENT TO PROFESSIONAL SERVICES AGREEMENT WITH HQE SYSTEMS IN THE AMOUNT OF $4,195
Presentation by Vanessa Hevener, Senior Management Analyst Public Comment: Jim Aichele
Motion by Councilmember Pieper, seconded by Councilmember Dieringer to send out a blue newsletter with one side being the simplified eight proposed locations map; on the other side display the pictures depicting what the siren look like; communicate that the City Council is soliciting feedback, and will continue to have this conversation in January. Motion carried unanimously with the following vote:
AYES: Black, Dieringer, Pieper, Mirsch, Mayor Wilson
NOES: None
ABSENT: None
13. MATTERS FROM THE CITY COUNCIL
The City Council discussed General Fund Reserves quarterly report. No action was taken.
14. MATTERS FROM STAFF – NONE
15. RECESS TO CLOSED SESSION – NONE
16. RECONVENE TO OPEN SESSION – NONE
17. ADJOURNMENT: 8:58 P.M.
The meeting was adjourned in memory of Carla Routt who passed away on December 2, 2022 at 8:58 p.m on December 13, 2022. The next regular adjourned meeting of the City Council is scheduled to be held on Monday, January 9, 2023 beginning at 7:00 p.m. in the City Council Chamber at City Hall, 2 Portuguese Bend Road, Rolling Hills, California. It will also be available via City’s website link at: https://www.rollinghills.org/government/agenda/index.php All written comments submitted are included in the record and available for public review on the City website.
Respectfully submitted,
16 MINUTES – CITY COUNCIL MEETING
Monday, December 13, 2022
____________________________________
Christian Horvath, City Clerk
Approved,
____________________________________
Patrick Wilson, Mayor
17 Agenda Item No.: 7.D
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: CHRISTIAN HORVATH, CITY CLERK / EXECUTIVE ASSISTANT TO
CITY MANAGER
THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: PAYMENT OF BILLS.
DATE: January 09, 2023
BACKGROUND:
None.
DISCUSSION:
None.
FISCAL IMPACT:
None.
RECOMMENDATION:
Approve as presented.
ATTACHMENTS:
CL_AGN_230109_CC_PaymentOfBills.pdf
18 19
20 Agenda Item No.: 7.E
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: CHRISTIAN HORVATH, CITY CLERK / EXECUTIVE ASSISTANT TO
CITY MANAGER
THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: APPROVE CITY COUNCIL MEETING DATES FOR CALENDAR YEAR 2023
DATE: January 09, 2023
BACKGROUND:
Annually in January, the City Council establishes the meeting dates for the calendar year.
DISCUSSION:
There are no conflicts between regularly scheduled City Council meetings and holidays for calendar year 2023.
FISCAL IMPACT:
None.
RECOMMENDATION:
Approve as presented.
ATTACHMENTS:
CL_AGN_230109_CC_2023_MeetingDates.pdf
21 2023 City Council Meeting Dates and City Holidays
Unless otherwise noted, meetings in conflict with a holiday will be cancelled.
Unless otherwise noted, meetings in
conflict with a holiday will be cancelled. DRAFT 11/02/22 Scheduled Date Holiday Conflict Holiday Date Re-scheduled Date/Time January 9, 2023
January 23, 2023
February 13, 2023
February 27, 2023
March 13, 2023
March 27, 2023
April 10, 2023
April 24, 2023
May 8, 2023
May 22, 2023
June 12, 2023
June 26, 2023
July 10, 2023
July 24, 2023
August 14, 2023
August 28, 2023
September 11, 2023
September 25, 2023
October 9, 2023
October 23, 2023
November 13, 2023
November 27, 2023
December 11, 2023 Holiday Open House N/A N/A
12/XX/2023
2023 Holidays Observed (City Hall Closed) Other Holidays:
January 1, 2023 New Year's Day (observed) March 27 - March 31, 2023 PVPUSD Spring Break January 16, 2023 Martin Luther King Jr. Day April 5 - April 13, 2023 Passover February 20, 2023 President's Day September 15 - 17, 2023 Rosh Hashanah May 29, 2023 Memorial Day September 24 - 25, 2023 Yom Kippur July 4, 2023 Independence Day
September 4, 2023 Labor Day
November 11, 2023 Veterans Day
November 23-24, 2023 Thanksgiving Holiday
December 24, 2023 Christmas Eve (Observed)
December 25, 2023 Christmas Day
22 Agenda Item No.: 7.F
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: CHRISTIAN HORVATH, CITY CLERK / EXECUTIVE ASSISTANT TO
CITY MANAGER
THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: APPROVE ANNUAL VENDOR LIST FOR CALENDAR YEAR 2023 DATE: January 09, 2023
BACKGROUND:
Section 3.04.060 of the City's Municipal Code regarding purchasing provides that the City purchases may be made from vendors without bidding when any of the following conditions exist:
1. The amount of the purchase has a total estimated value of less than two thousand five hundred dollars ($2,500)
2. Sole source purchases such as legal advertising, utility, conferences, and Sheriff's Department services.
3. An essential or critical need requires that an order be placed with the best available source of supply due to time constraints.
4. Purchases from vendors on the City Council Approved Vendor's List.
5. If, at the discretion of the City Manager, and upon a finding supported with written documentation, it is in the City's best interest in regard to product uniformity, total cost acquisition, and/or similar considerations. These purchases must be approved by the City Manager or his/her designee.
6. Purchases made through a Cooperative Purchasing Program utilizing purchasing agreements maintained by the State, County, or other public agencies.
DISCUSSION:
Annually the City Council approves a Vendor List for the calendar year to facilitate purchases of material and services. The updated Vendor List for calendar year 2023 is comprised of vendors who have consistently provided excellent service to the City. In a competitive setting, these vendors have been historically the lowest bidders and they have proven to deliver goods and or services timely.
FISCAL IMPACT:
None.
23 RECOMMENDATION:
Approve as presented.
ATTACHMENTS:
VC_230109_PreferredVendorList.pdf
24 Vendor Name Address Contact Phone Web Service Provided 4 Over Inc. 1225 Los Angeles Street, Glendale,
CA 91204 877-782-2737 4over.com Printing Services
A-1 All American Roofing Co. 22029 S. Figueroa St., Carson, CA 90745 Craig Ekberg 310-320-0224 800roofusa.com Roofing company Abila 9620 Executive Center Dr. North
#200, St. Petersburg, FL 33702 800-811-0961 www.mip.com Accounting Software Amazon.com amazon.com Office Supplies
Armstrong Nursery 25225 Crenshaw Blvd., Torrance, CA
90505 (310) 326-1892 Christmas tree
Black Box Audio Visual Services 4757 Norelle St., Los Angeles, CA 90032
Miguel Diaz
Camacho 323-899-1435 blackboxaudiovideoservices.com
Electrician / A/V Services
CBE Office Solutions 4 Mason, Irvine, CA 92618 Joe Graziano / Chris Hoffie 310.323.3310 www.cbesolutions.com Copier and office equipment supplier Chambers Group 5 Hutton Centre Dr., Ste. 750, Santa
Ana, CA 92707 chambersgroupinc.com Environmental Consultant Civic Plus P.O. Box 2235 Tallahassee, FL
32316 Sylvana Satterfield 800-262-2633 civicplus.com Online Muni Code System Complete Fire Services Inc. PO Box 3804 Tustin, CA 92781 (949) 468-0363 Fire Extinguishers Costco Wholesale 2640 Lomita Blvd., Torrance, CA
90505 (310) 891-1020 costco.com Office Supplies
Cox Com, LLC 29947 Avenida De Las Banderas,
Rancho Santa Margarita, CA 92688
(310) 891-1020
or 949-546-2406 cox.com Telephone / cable internet services Daily Breeze / Southern California News Group PO Box 8012, Willoughby, OH 44096- 8012 Pauline Fernandez 310.543.6635 publicnotices.scng.com Newspaper / Public Notices David Fairchild Studio P.O. Box 2424 Palos Verdes
Peninsula CA 90274 David Fairchild (310) 316-5547 davidfairchildstudio.com Photography Services Dell, Inc. One Dell Way, Round Rock, TX
78682 (800) 677-9725 Dell.com Computer equipment
DFM Associates 10 Chrysler, Suite A | Irvine, CA
92618 Deborah Ferrante 949.859.8700 www.dfmassociates.com Election Code Updates Diane Gladwell 1028 Tirol Lane, Lake Arrowhead,
CA 92352 (909) 337-3516 Election consultant, records
management
Endee - Two Hands Woodworks, Inc. 2109 N Rosewood Ave. Santa Ana, CA. 92706 Noel Bonn 657-559-906 endee.art Specialty Items (Plaques) Environmental Design Associates (EDA) 14121 Sawston Circle, Westminster, CA 92683 (714) 350-6910 Landscape Plan Review
25 Executive-Suite Services 19025 Parthenia St. Suite 200, Northridge, CA 91324 818-993-6300 Janitorial services
Exsel Inc. 1854 West 169th Street, Unit G,
Gardena, CA 90247 310.933.3012 exselusa.com Printing / promotional services File Keepers LLC 6277 East Slauson Avenue, Los
Angeles, CA 90040 Lance Hom 213.250.3000 www.filekeepers.com Laserfiche File Retention / Storage Finley Tree & Land Care Service 23033 Crenshaw Blvd, Torrance, CA 90505 (310) 326-9818 Tree trimming services, landscaping First Call Staffing 3511 Pacific Coast Hwy # E,
Torrance, CA 90505 (310) 539-2884 Employment agency
iWorQ PO Box 3784, Logan UT 84323 435-755-5126 www.iworq.net Planning / Code Enforcement Database
JTL Consultant 952 Buena Vista Street, Duarte, CA
91010 (626) 358-5690 Arborist
Konica Minolta Business Solution, USA Inc. Dept. LA 22988, Pasadena, CA 91185-2988 (800) 456-5664 Copier and office equipment supplier Kosmont Transaction Services 1601 N. Sepulveda Blvd. #382, Manhattan Beach, CA 90266 Larry Kosmont 424-297-1070 Financial Consultants Lisa’s Bon Appetit 3535 Lomita Blvd Suite C, Torrance,
CA 90505 (310) 784-1070 Catering service
Mahaffey Companies (Atlas Cesspool Service) 1800 S. Alameda St., Rancho Dominguez, Ca. 90221 (310) 605-1700 Septic tank services Mark Towle 2919 W. 154th St., Gardena, CA
90249 Bartending Services
MCA Direct LLC 1961 E Wright Circle Anaheim, CA
92806 Erin Martin Picon 714-939-9866 mcadirect.org Election Materials Michael Baker International 3760 Kilroy Airport Way, Ste. 270, Long Beach, CA 90806 (562) 200-7165 Plancheck, Peer Review Nextiva 9451 East Via de Ventura,
Scottsdale, AZ 85256 800-285-7995 www.nextiva.com Phone Systems Nothing Bundt Cakes 5205 Pacific Coast HWY, Unit B/C,
Torrance, CA 90505 (310) 373-2443 Desserts
OfficeDepot.com Office Supplies
On Time Delivery 20550 Earl St. #50, Torrance, CA
90503 Howard Simon (310) 874-7267 Messenger Services
Orkin 12710 Magnolia Ave., Riverside, CA
92503-4620 Jesse Jolly (323) 244-7990 Pest Control
26 Palos Verdes Florist 910 Silver Spur Rd, Rolling Hills Estates, CA 90274 (310) 541-9994 palosverdesflorist.com Florist Palos Verdes Security Systems Inc. / Valley Alarm 804 Pico Street, San Fernando, CA 91340 800-550-2537 www.valleyalarm.com Security System
Peninsula Septic 1840 S. Gaffey Street #53, San
Pedro, CA 90731 Nick Dragich (310) 832-4800 Septic tank services Pitney Bowes Postage PO Box 981026, Boston , MA 02298-
1026 www.pitneybowes.com Postage
Providence Health & Services PO Box 4017, Portland, OR 97208- 4017 Pre-Employment Health Services
PVPUSD Printing Services 375 Via Almar, Palos Verdes Estates CA 90274 310-896-3426 Copy & stationary printing services Quadiaent, Inc. Dept. 3689, PO Box 123689, Dallas,
TX 75312-3689 www.quadient.com Finance / Account Payable RACE Communication 1170 Unit C, E Tehachapi Blvd.,
Tehachapi, CA 93561 (877) 722-3833 Internet Communications Robert Half 970 West 190th St., Suite 400,
Torrance, CA 90502 (800) 804-8367 Employment agency
Sir Speedy 900 W. 223rd St., Torrance, Ca
90502 310-212-6162 www.sirspeedysouthbay.
net Copy / Printing Services
Smart Source LLC. 21818 S. Wilmington Ave., Ste 406,
Long Beach, CA 90810 (310) 513-2000 Stationery
South Bay Workforce Investment Board 11539 Hawthorne Blvd #500, Hawthorne, CA 90250 Robert Chavez (310) 970-7700 www.sbwib.org Employment Resources Stephens Plumbing & Heating Company 616 W 6th Street, San Pedro, CA 90731 (310) 832-9009 Plumbing and Heating
Total Compensation System Inc. 5655 Lindero Canyon Rd #223, Westlake Village, CA 91362 Financial Services GASB 75
TR Trading Co. 15604 S. Broadway, Gardena, CA
90248 (310) 329-9242 Furniture store
Traver’s Trees P. O. Box 7000-416, Palos Verdes
Peninsula, CA 90274
(310) 545-5816 or
(310) 530-3920 Tree trimming services, landscaping
Trio Event Rental 7900 Balboa Blvd B3, Van Nuys, CA
91406 (818) 651-0602 trioeventrentals.com Event rentals Warriner Associates 47-568 Hakulhale Street, Kaneohe,
HI 96744 310-378-1764 Arborist
Western Audio Visual 1592 N. Batavia, Ste. 2, Orange, CA, 92867 Kevin Mahkorn (714) 637-4461 www.wav1.com A/V Tech and Design Services 27 Worldwise Productions 20945 Devonshire St, Chatsworth, CA 91311 (877) 997-8433 wwpvideo.com Video Production Services Xerox 101 Continental Blvd. El Segundo,
CA 90245 Lori Murphy (877) 395-6318 Xerox.com Printers, copiers Yosemite Water 226 South Avenue 54, Los Angeles,
CA 90025 (323) 256-2265 yosemitewaters.com Water delivery 28 Agenda Item No.: 7.G
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: VANESSA HEVENER, SENIOR MANAGEMENT ANALYST
THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: APPROVE REPUBLIC SERVICES' 2023 CLEAN-UP AND COMMUNAL
BIN SCHEDULE
DATE: January 09, 2023
BACKGROUND:
Republic Services' annual clean-up and communal bin events were coordinated with the Rolling Hills Community Association.
DISCUSSION:
The 2023 events are scheduled as follows:
Communal Bin Events
January 20-27
August 4-12
Spring
Green Waste – Wednesday, March 8th
Bulky Items – Wednesday, March 15th
Document Shredding & Electronic Waste Recycling – Saturday, March 25th Fall
Green Waste – Wednesday, October 4th
Bulk Items – Wednesday, October 11th
Document Shredding & Electronic Waste Recycling – Saturday, October 21st FISCAL IMPACT:
The twice a year clean up and communal bin events are included in the franchise agreement between the City and Republic Services.
RECOMMENDATION:
Approve as presented.
29 ATTACHMENTS:
30 Agenda Item No.: 7.H
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: JOHN SIGNO, DIRECTOR OF PLANNING & COMMUNITY SERVICES THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: FOR SECOND READING AND ADOPTION: ADOPT BY TITLE ONLY ORDINANCE NO. 381 AMENDING CHAPTER 17.28 OF THE ROLLING
HILLS MUNICIPAL CODE REGARDING ACCESSORY DWELLING
UNITS AND JUNIOR ACCESSORY DWELLING UNITS AND
DETERMINING THE ORDINANCES TO BE EXEMPT FROM CEQA
DATE: January 09, 2023
BACKGROUND:
On November 15, 2022, this item was recommended for approval by the Planning Commission on a 5-0 vote. On December 13, 2022, the City Council held a duly noticed public hearing, took public testimony, and closed the public hearing. At the conclusion of the hearing, the City Council adopted Ordinance No. 381-U and introduced Ordinance No. 381 for first reading amending Chapter 17.28 of the Rolling Hills Municipal Code regarding accessory dwelling units (ADUs) and junior accessory dwelling units (JADUs) and finding the action to be exempt from the California Environmental Quality Act (CEQA). Ordinance No. 381-U is an urgency ordinance that became effective immediately and became operative on January 1, 2023.
Recent ADU Laws:
In recent years, the California Legislature has approved, and the Governor has signed into law, a number of bills that impose limits on local authority to regulate accessory dwelling units (“ADUs”) and junior accessory dwelling units (“JADUs”). These bills include Assembly Bills 68 and 881 and Senate Bill 13—which went into effect on January 1, 2020. The City Council previously adopted Ordinance Nos. 364U and 364, which updated the City’s ADU and JADU regulations (contained in Chapter 17.28 of the Rolling Hills Municipal Code) to comply with this legislation.
Following the bills noted above, in 2020 and 2021 the California Legislature approved, and the Governor signed into law, Assembly Bill 3182 (“AB 3182”) and Assembly Bill 345 (“AB 345”), respectively. Among other things, AB 3182 expanded the scenarios under which the City must allow certain ADUs and JADUs with only a building permit. AB 345 required cities to allow the separate sale or conveyance of certain ADUs that satisfy the conditions set forth in 31 Government Code section 65852.26. Such conditions include, among other things, that the ADU or the primary dwelling was constructed by a qualified nonprofit and the ADU is sold to a qualified low-income buyer. In August 2022, the City Council adopted Ordinance No. 376, which further amended the City’s ADU and JADU regulations to comply with this legislation.
DISCUSSION:
In September 2022, the California Legislature approved, and the Governor signed into law, a new bill (“SB 897”) that further amends state ADU law (i.e., Government Code sections 65852.2 and 65852.22).
Among other things, SB 897: 1
Requires the City to allow certain ADUs to be higher—up to 18 or 25 feet, depending the situation;
Requires the City’s front setback requirement to yield for certain ADUs; Requires the City to justify a denial with a full set of detailed comments describing the deficiencies in the application and explaining how to remedy them; Removes the automatic repeal in 2025 (now the ADU statute is permanent); Prohibits the City from denying an application to create an ADU solely because corrections are needed to address nonconforming zoning conditions, building code violations, or unpermitted structures elsewhere on the lot that do not present a threat to public health and safety and are not affected by the construction of the ADU; and In instances where a JADU will share a bathroom with the primary dwelling, the City must require the JADU to have an interior entry to the primary dwelling’s “main living area,” independent of the exterior entrances of the JADU and primary dwelling.
As noted above, the City’s ADU and JADU regulations are codified in RHMC Chapter 17.28.
Included in Attachment 1 is an ordinance (“ADU Ordinance”) that amends Chapter 17.28 to comply with SB 897.
The code amendments provided in the ADU Ordinance are mandated by recent changes in state law. Consequently, staffs’ recommendation is for the City Council to adopt the ADU Ordinance.
ENVIRONMENTAL IMPACT
Under California Public Resources Code section 21080.17, the California Environmental Quality Act (“CEQA”) does not apply to the adoption of an ordinance by a city or county implementing the provisions of section 65852.2 of the Government Code, which is California’s ADU law and which also regulates JADUs, as defined by section 65852.22. Therefore, the ADU Ordinance is statutorily exempt from CEQA in that the proposed ordinance implements state’s ADU law.
__________________
1 Both AB 2221 and SB 897 were signed into law, but AB 2221 has no effect because it would have amended the same statute that SB 897 amended, and SB 897 was signed into law (chaptered) later. AB 2221 was therefore “chaptered out.” But section 2.5 of SB 897 expressly includes, among others, changes to the ADU law that would have been made by AB 2221. Ultimately, only SB 897 is effective and relevant.
32 FISCAL IMPACT:
The ordinance amendment brings the Municipal Code into compliance with State law which protects the City from legal challenges.
RECOMMENDATION:
Adopt by title only Ordinance No. 381, entitled, " AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF ROLLING HILLS AMENDING CHAPTER 17.28 OF THE ROLLING HILLS
MUNICIPAL CODE REGARDING ACCESSORY DWELLING UNITS AND JUNIOR
ACCESSORY DWELLING UNITS AND DETERMINING THE ORDINANCE TO BE EXEMPT FROM CEQA."
ATTACHMENTS:
Attachment 1 - CL_ORD_381_ADU Ordinance_D3.pdf
33 65277.00010\40820289.1
- 1 -
ORDINANCE NO. 381
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF
ROLLING HILLS AMENDING CHAPTER 17.28 OF THE
ROLLING HILLS MUNICIPAL CODE REGARDING
ACCESSORY DWELLING UNITS AND JUNIOR
ACCESSORY DWELLING UNITS AND DETERMINING THE
ORDINANCE TO BE EXEMPT FROM CEQA
WHEREAS, the City of Rolling Hills, California (“City”) is a municipal corporation, duly organized under the constitution and laws of the State of California; and WHEREAS, state law authorizes cities to act by ordinance to provide for the creation and regulation of accessory dwelling units (“ADUs”) and junior accessory dwelling units (“JADUs”); and
WHEREAS, in 2019, the California Legislature approved, and the Governor signed into law a number of bills (“2019 ADU Laws”) that, among other things, amended Government Code section 65852.2 and 65852.22 to impose new limits on local authority to regulate ADUs and JADUs; and
WHEREAS, in February 2020, the City Council adopted Ordinance Nos. 364U and 364, which updated the City’s ADU and JADU regulations (contained in Chapter 17.28 of the Rolling Hills Municipal Code) to comply with the 2019 ADU Laws; and WHEREAS, in August 2022, the City Council adopted Ordinance No. 376, which further amended the City’s ADU and JADU regulations to comply with state law, including Assembly Bills 345 and 3182; and
WHEREAS, in September 2022, the Legislature approved, and the Governor signed into law, Senate Bill 897 (“SB 897”); and
WHEREAS, SB 897 imposed further restrictions on local authority to regulate ADUs and JADUs, including with respect to height limits, setbacks, application review and denial procedures, unpermitted structures, and JADU configurations; and WHEREAS, this ordinance (“Ordinance”) amends the City’s ADU and JADU regulations to comply with SB 897; and
WHEREAS, on November 15, 2022, the Planning Commission conducted a duly noticed public hearing to consider the Ordinance, wherein it considered the staff report, supporting documents, public testimony, and all appropriate information submitted with the Ordinance. Following the public hearing, the Planning Commission recommended that the Council adopt the Ordinance; and
WHEREAS, on December 13, 2022, the City Council conducted a duly noticed public hearing to Consider the Ordinance, wherein it considered the staff report and 34 65277.00010\40820289.1
- 2 -
supporting documents, Planning Commission’s recommendation, public testimony, and all appropriate information submitted with the Ordinance; and WHEREAS, all legal prerequisites to the adoption of the Ordinance have occurred.
NOW, THEREFORE, the City Council of the City of Rolling Hills does ordain as follows:
SECTION 1. Incorporation of Recitals. The recitals above are each incorporated by reference and adopted as findings by the City Council.
SECTION 2. CEQA. Under California Public Resources Code section 21080.17, the California Environmental Quality Act (“CEQA”) does not apply to the adoption of an ordinance by a city or county implementing the provisions of section 65852.2 of the Government Code, which is California’s ADU law and which also regulates JADUs, as defined by section 65852.22. Therefore, the Ordinance is statutorily exempt from CEQA in that the proposed ordinance implements the State’s ADU law.
SECTION 3. General Plan. This Ordinance is, as a matter of law, consistent with the City’s General Plan pursuant to Government Code Section 65852.2(a)(1)(C).
SECTION 4. Code Amendments. Chapter 17.28 of the Rolling Hills Municipal Code is hereby amended and restated to read in its entirety as provided in Exhibit “A,” attached hereto and incorporated herein by reference.
SECTION 5. Submittal to HCD. The City Clerk shall submit a copy of this Ordinance to the Department of Housing and Community Development within 60 days after adoption.
SECTION 6. Severability. If any provision of this Ordinance or its application to any person or circumstance is held to be invalid, such invalidity has no effect on the other provisions or applications of the Ordinance that can be given effect without the invalid provision or application, and to this extent, the provisions of this Ordinance are severable.
The City Council declares that it would have adopted this Ordinance irrespective of the invalidity of any portion thereof.
35 65277.00010\40820289.1
- 3 -
SECTION 7. Effective Date. This Ordinance takes effect 30 days following its adoption.
SECTION 8. Certification. The City Clerk is hereby directed to certify to the passage and adoption of this Ordinance; cause the same, or a summary thereof, to be published or posted in the manner required by law.
PASSED, APPROVED and ADOPTED this 9th day of January, 2023. ____________________________
James Black, Mayor
ATTEST:
______________________________
Christian Horvath, City Clerk
APPROVED AS TO FORM:
________________________________
Patrick Donegan, City Attorney
36 65277.00010\40820289.1
- 4 -
STATE OF CALIFORNIA )
COUNTY OF LOS ANGELES ) §§
CITY OF ROLLING HILLS )
I, Christian Horvath, City Clerk of the City of Rolling Hills, California, do hereby certify that the foregoing Ordinance No. 381 was adopted at a regular meeting of the City Council of the City of Rolling Hills held on the 9th day of January, 2023, by the following vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
______________________________
Christian Horvath
City Clerk
37 65277.00010\40820289.1
- 5 -
EXHIBIT A
Amended ADU Regulations
(Follows this page)
38 65277.00010\40812719.3
Chapter 17.28 ACCESSORY DWELLING UNITS AND JUNIOR ACCESSORY
DWELLING UNITS
17.28.010 Purpose.
The purpose of this section is to allow and regulate accessory dwelling units (ADUs) and junior accessory dwelling units (JADUs) in compliance with California Government Code Sections 65852.2 and 65852.22.
17.28.020 Effect of conforming.
An ADU or JADU that conforms to the standards in this section will not be:
A. Deemed to be inconsistent with the City's General Plan and Zoning designation for the lot on which the ADU or JADU is located.
B. Deemed to exceed the allowable density for the lot on which the ADU or JADU is located.
C. Considered in the application of any local ordinance, policy, or program to limit residential growth.
D. Required to correct a nonconforming zoning condition, as defined in Section
17.28.030(G) below. This does not prevent the City from enforcing compliance with applicable building standards in accordance with Health and Safety Code Section 17980.12.
17.28.030 Definitions.
As used in this section, terms are defined as follows:
A. "Accessory dwelling unit" or "ADU" means an attached or a detached residential dwelling unit that provides complete independent living facilities for one or more persons and is located on a lot with a proposed or existing primary residence. An accessory dwelling unit also includes the following:
1. An efficiency unit, as defined by Section 17958.1 of the California Health and Safety Code; and
2. A manufactured home, as defined by Section 18007 of the California Health and Safety Code.
B. "Accessory structure" means a structure that is accessory and incidental to a dwelling located on the same lot.
C. "Complete independent living facilities" means permanent provisions for living, sleeping, eating, cooking, and sanitation on the same parcel as the single-family or multifamily dwelling is or will be situated.
D. "Efficiency kitchen" means a kitchen that includes all of the following:
1. A cooking facility with appliances.
39 65277.00010\40812719.3
2. A food preparation counter and storage cabinets that are of a reasonable size in relation to the size of the JADU.
E. "Junior accessory dwelling unit" or "JADU" means a residential unit that satisfies all of the following:
1. It is no more than five hundred square feet in size.
2. It is contained entirely within an existing or proposed single-family dwelling.
An enclosed use within the residence, such as an attached garage, is considered to be a part of and contained within the single-family dwelling.
3. It includes its own separate sanitation facilities or shares sanitation facilities with the existing or proposed single-family dwelling.
4. If the unit does not include its own separate bathroom, then it contains an interior entrance to the main living area of the existing or proposed singlefamily dwelling in addition to an exterior entrance that is separate from the main entrance to the primary dwelling.
5. It includes an efficiency kitchen, as defined in subsection (D) above.
F. "Living area" means the interior habitable area of a dwelling unit, including basements and attics, but does not include a garage or any accessory structure.
G. "Nonconforming zoning condition" means a physical improvement on a property that does not conform with current zoning standards.
H. "Passageway" means a pathway that is unobstructed clear to the sky and extends from a street to one entrance of the ADU or JADU.
I. "Proposed dwelling" means a dwelling that is the subject of a permit application and that meets the requirements for permitting.
J. "Public transit" means a location, including, but not limited to, a bus stop or train station, where the public may access buses, trains, subways, and other forms of transportation that charge set fares, run on fixed routes, and are available to the public.
K. "Tandem parking" means that two or more automobiles are parked on a driveway or in any other location on a lot, lined up behind one another.
17.28.040 Approvals.
The following approvals apply to ADUs and JADUs under this section:
A. Building-permit Only. If an ADU or JADU complies with each of the general requirements in Section 17.28.050 below, it is allowed with only a building permit in the following scenarios:
1. Converted on Single-family Lot: One ADU as described in this subsection (A)(1) and one JADU on a lot with a proposed or existing single-family dwelling on it, where the ADU or JADU:
40 65277.00010\40812719.3
(a) Is either: within the space of a proposed single-family dwelling; within the existing space of an existing single-family dwelling; or (in the case of an ADU only) within the existing space of an accessory structure, plus up to one hundred fifty additional square feet if the expansion is limited to accommodating ingress and egress; and (b) Has exterior access that is independent of that for the single-family dwelling; and
(c) Has side and rear setbacks sufficient for fire and safety, as dictated by applicable building and fire codes.
2. Limited Detached on Single-family Lot: One detached, new construction ADU on a lot with a proposed or existing single-family dwelling (in addition to any JADU that might otherwise be established on the lot under subsection (A)(1) above), if the detached ADU satisfies each of the following limitations:
(a) The side- and rear-yard setbacks are at least four feet. (b) The total floor area is eight hundred square feet or smaller. (c) The peak height above grade does not exceed the applicable height limit provided in section 17.28.050(B).
3. Converted on Multifamily Lot: One or more ADUs within portions of existing multifamily dwelling structures that are not used as livable space, including but not limited to storage rooms, boiler rooms, passageways, attics, basements, or garages, if each converted ADU complies with state building standards for dwellings. Under this subsection (A)(3), at least one converted ADU is allowed within an existing multifamily dwelling, up to a quantity equal to twenty-five percent of the existing multifamily dwelling units.
4. Limited Detached on Multifamily Lot: No more than two detached ADUs on a lot that has an existing or proposed multifamily dwelling if each detached ADU satisfies both of the following limitations:
(a) The side- and rear-yard setbacks are at least four feet. If the existing multifamily dwelling has a rear or side yard setback of less than four feet, the City will not require any modification to the multifamily dwelling as a condition of approving the ADU.
(b) The peak height above grade does not exceed the applicable height limit provided in section 17.28.050(B).
B. ADU Permit.
1. Except as allowed under subsection (A) above, no ADU may be created without a building permit and an ADU permit in compliance with the standards set forth in Section 17.28.050 and Section 17.28.060.
2. The City may charge an application fee, adopted by resolution of the City Council, to reimburse it for costs incurred in processing ADU permits. 41 65277.00010\40812719.3
C. Process and Timing.
1. An ADU permit is considered and approved ministerially, without discretionary review or a hearing.
2. The City must approve or deny an application to create an ADU or JADU within sixty days from the date that the City receives a completed application. If the City has not approved or denied the completed application within sixty days, the application is deemed approved unless either:
(a) The applicant requests a delay, in which case the sixty-day time period is tolled for the period of the requested delay, or (b) When an application to create an ADU or JADU is submitted with a permit application to create a new single-family or multifamily dwelling on the lot, the City may delay acting on the permit application for the ADU or JADU until the City acts on the permit application to create the new single-family or multifamily dwelling, but the application to create the ADU or JADU will still be considered ministerially without discretionary review or a hearing.
3. If the City denies an application to create an ADU or JADU, the City must provide the applicant with comments that include, among other things, a list of all the defective or deficient items and a description of how the application may be remedied by the applicant. Notice of the denial and corresponding comments must be provided to the applicant within the sixty day time period established by subsection (C.2) above.
4. A demolition permit for a detached garage that is to be replaced with an ADU is reviewed with the application for the ADU and issued at the same time.
17.28.050 General ADU and JADU requirements.
The following requirements apply to all ADUs and JADUs that are approved under Section
17.28.040(A) or (B):
A. Zoning.
1. An ADU or JADU subject only to a building permit under Section
17.28.040(A) may be created on a lot in a residential or mixed-use zone.
2. An ADU or JADU subject to an ADU permit under Section 17.28.040(B) may be created on a lot that is zoned to allow single-family dwelling residential use or multifamily dwelling residential use.
B. Height.
1. Except as otherwise provided by subsections (B.2) and (B.3) below, a detached ADU created on a lot with an existing or proposed single family or multifamily dwelling unit may not exceed sixteen feet in height.
2. A detached ADU may be up to eighteen feet in height if it is created on a lot with an existing or proposed single family or multifamily dwelling unit that is 42 65277.00010\40812719.3
located within one-half mile walking distance of a major transit stop or a high quality transit corridor, as those terms are defined in Section 21155 of the Public Resources Code, and the ADU may be up to two additional feet in height (for a maximum of twenty feet) if necessary to accommodate a roof pitch on the ADU that is aligned with the roof pitch of the primary dwelling unit.
3. A detached ADU created on a lot with an existing or proposed multifamily dwelling that has more than one story above grade may not exceed eighteen feet in height.
4. An ADU that is attached to the primary dwelling may not exceed twenty five feet in height or the height limitation imposed by the underlying zone that applies to the primary dwelling, whichever is lower.
5. For purposes of this subsection (B), height is measured above existing legal grade to the peak of the structure.
C. Fire Sprinklers.
1. Fire sprinklers are required in an ADU if sprinklers are required in the primary residence.
2. The construction of an ADU does not trigger a requirement for fire sprinklers to be installed in the existing primary dwelling.
D. Rental Term. No ADU or JADU may be rented for a term that is shorter than thirty days. This prohibition applies regardless of when the ADU or JADU was created.
E. No Separate Conveyance. An ADU or JADU may be rented, but, except as otherwise provided in Government Code Section 65852.26, no ADU or JADU may be sold or otherwise conveyed separately from the lot and the primary dwelling (in the case of a single-family lot) or from the lot and all of the dwellings (in the case of a multifamily lot).
F. Owner Occupancy.
1. An ADU that is permitted after January 1, 2020, but before January 1, 2025, is not subject to any owner-occupancy requirement.
2. Unless applicable law requires otherwise, all ADUs that are permitted on or after January 1, 2025, are subject to an owner-occupancy requirement. A natural person with legal or equitable title to the property must reside on the property as the person's legal domicile and permanent residence.
3. As required by state law, all JADUs are subject to an owner-occupancy requirement. A natural person with legal or equitable title to the property must reside on the property, in either the primary dwelling or JADU, as the person's legal domicile and permanent residence. However, the owneroccupancy requirement of this paragraph does not apply if the property is entirely owned by another governmental agency, land trust, or housing organization.
43 65277.00010\40812719.3
G. Deed Restriction. Prior to issuance of a building permit for an ADU or JADU, a deed restriction must be recorded against the title of the property in the County Recorder's office and a copy filed with the Director. The deed restriction must run with the land and bind all future owners. The form of the deed restriction will be provided by the City and must provide that:
1. Except as otherwise provided in Government Code Section 65852.26, the ADU or JADU may not be sold separately from the primary dwelling.
2. The ADU or JADU is restricted to the approved size and to other attributes allowed by this chapter.
3. The deed restriction runs with the land and may be enforced against future property owners.
4. The deed restriction may be removed if the owner eliminates the ADU or JADU, as evidenced by, for example, removal of the kitchen facilities. To remove the deed restriction, an owner may make a written request of the Director, providing evidence that the ADU or JADU has in fact been eliminated. The Director may then determine whether the evidence supports the claim that the ADU or JADU has been eliminated. Appeal may be taken from the Director's determination consistent with other provisions of this Code. If the ADU or JADU is not entirely physically removed, but is only eliminated by virtue of having a necessary component of an ADU or JADU removed, the remaining structure and improvements must otherwise comply with applicable provisions of this Code.
5. The deed restriction is enforceable by the Director or his or her designee for the benefit of the City. Failure of the property owner to comply with the deed restriction may result in legal action against the property owner, and the City is authorized to obtain any remedy available to it at law or equity, including, but not limited to, obtaining an injunction enjoining the use of the ADU or JADU in violation of the recorded restrictions or abatement of the illegal unit.
H. Building and Safety.
1. Must comply with building code. Subject to subsection (H)(2) below, all ADUs and JADUs must comply with all local building code requirements.
2. No change in occupancy. Construction of an ADU does not constitute a Group R occupancy change under the local building code, as described in Section 310 of the California Building Code, unless the building official or Code Enforcement Division officer makes a written finding based on substantial evidence in the record that the construction of the ADU could have a specific, adverse impact on public health and safety. Nothing in this subsection (H)(2) prevents the City from changing the occupancy code of a space that was uninhabitable space or that was only permitted for nonresidential use and was subsequently converted for residential use in accordance with this section.
44 65277.00010\40812719.3
17.28.060 Specific ADU requirements.
The following requirements apply only to ADUs that require an ADU permit under Section
17.28.040(B).
A. Maximum Size.
1. The maximum size of a detached or attached ADU subject to this Section
17.28.060 is eight hundred fifty square feet for a studio or one-bedroom unit and one thousand square feet for a unit with two or more bedrooms.
2. An attached ADU that is created on a lot with an existing primary dwelling is further limited to fifty percent of the floor area of the existing primary dwelling, subject to subsection (A)(3) below.
3. Application of other development standards in this Section 17.28.060, such as FAR or lot coverage, might further limit the size of the ADU, but no application of the percentage-based size limit in subsection (A)(2) above, or of an FAR, lot coverage limit or open-space requirement may require the ADU to be smaller than eight hundred square feet.
B. Floor Area Ratio (FAR). No ADU subject to this Section 17.28.060 may cause the total FAR of the lot to exceed forty-five percent, subject to Section 17.28.060(A)(3) above.
C. Setbacks.
1. Front Yard.
(a) Subject to subsection (C)(1)(b) below, no part of any ADU subject to this Section 17.28.060 may be located within thirty feet of the front property line.
(b) If the front yard setback is the only location on the lot where an ADU may be lawfully constructed, then the ADU may encroach into the required front yard setback as necessary to enable the construction of an eight hundred square foot unit.
2. No part of any ADU subject to this Section 17.28.060 may be located within four feet of a side or rear property line.
D. Lot Coverage. No ADU subject to this Section 17.28.060 may cause the total lot coverage of the lot to exceed fifty percent, subject to Section 17.28.060(A)(3) above.
E. Minimum Open Space. No ADU subject to this Section 17.28.060 may cause the total percentage of open space of the lot to fall below fifty percent, subject to subsection Section 17.28.060(A)(3) above.
F. Passageway. No passageway, as defined by Section 17.28.030(H) above, is required for an ADU.
G. Parking.
45 65277.00010\40812719.3
1. Generally. One off-street parking space is required for each ADU. The parking space may be provided in setback areas or as tandem parking, as defined by Section 17.28.030(K) above.
2. Exceptions. No parking under Section 17.28.060(G.1) is required in the following situations:
(a) The ADU is located within one-half mile walking distance of public transit, as defined in subsection Section 17.28.030(J) above. (b) The ADU is located within an architecturally and historically significant historic district.
(c) The ADU is part of the proposed or existing primary residence or an accessory structure under Section 17.28.040(A)(1) above. (d) When on-street parking permits are required but not offered to the occupant of the ADU.
(e) When there is an established car share vehicle stop located within one block of the ADU.
(f) When the permit application to create an ADU is submitted with an application to create a new single-family or new multifamily dwelling on the same lot, provided that the ADU or the lot satisfies any other criteria in subsections (G.2(a) through (G.2(e) above.
3. No Replacement. When a garage, carport, or covered parking structure is demolished in conjunction with the construction of an ADU or converted to an ADU, those off-street parking spaces are not required to be replaced.
H. Architectural Requirements.
1. The materials and colors of the exterior walls, roof, and windows and doors must match the appearance and architectural design of those of the primary dwelling.
2. The roof slope must match that of the dominant roof slope of the primary dwelling. The dominant roof slope is the slope shared by the largest portion of the roof.
3. The exterior lighting must be limited to down-lights or as otherwise required by the building or fire code.
4. The ADU must have an independent exterior entrance, apart from that of the primary dwelling.
5. The interior horizontal dimensions of an ADU must be at least ten feet wide in every direction, with a minimum interior wall height of seven feet.
6. Fencing, landscaping or privacy glass may be used to provide screening and prevent a direct line of sight to contiguous residential property.
7. The architectural treatment of an ADU to be constructed on a lot that has an identified historical resource listed on the California Register of Historic 46 65277.00010\40812719.3
Resources must comply with all applicable ministerial requirements imposed by the Secretary of Interior.
I. Landscape Requirements.
1. Evergreen landscape screening must be planted and maintained between the ADU and adjacent parcels as follows:
(a) At least one, fifteen-gallon size plant shall be provided for every five linear feet of exterior wall. Alternatively, at least one, twenty-four-inch box size plant shall be provided for every ten linear feet of exterior wall.
(b) Plant specimens for screening must be at least eight feet tall when installed. As an alternative, a solid fence of at least eight feet in height may be installed.
2. All landscaping must be drought-tolerant.
3. All landscaping must be from the City's approved plant list.
J. Historical Protections. An ADU that is subject to this Section 17.28.060 and that is on or within six hundred feet of real property that is listed in the California Register of Historic Resources must be located so as to not be visible from any public rightof-way.
17.28.070 Fees.
The following requirements apply to all ADUs and JADUs that are approved under Section
17.28.040(A) or Section 17.28.040(B).
A. Impact Fees.
1. No impact fee is required for an ADU that is less than seven hundred fifty square feet in size. For purposes of this Section 17.28.070, "impact fee" means a "fee" under the Mitigation Fee Act (Gov. Code § 66000(b)) and a fee under the Quimby Act (Gov. Code § 66477). "Impact fee" here does not include any connection fee or capacity charge for water or sewer service.
2. Any impact fee that is required for an ADU that is seven hundred fifty square feet or larger in size must be charged proportionately in relation to the square footage of the primary dwelling unit. (E.g., the floor area of the ADU divided by the floor area of the primary dwelling, times the typical fee amount charged for a new dwelling.)
B. Utility Fees.
1. If an ADU is constructed with a new single-family home, a separate utility connection directly between the ADU and the utility and payment of the normal connection fee and capacity charge for a new dwelling are required.
2. Except as described in subsection 17.28.070(B)(1), converted ADUs on a single-family lot that are created under Section 17.28.040(A)(1) above are 47 65277.00010\40812719.3
not required to have a new or separate utility connection directly between the ADU and the utility. Nor is a connection fee or capacity charge required.
3. Except as described in Section 17.28.070(B)(1), all ADUs not covered by Section 17.28.070(B)(2) above require a new, separate utility connection directly between the ADU and the utility.
(a) The connection is subject to a connection fee or capacity charge that is proportionate to the burden created by the ADU based on either the floor area or the number of drainage-fixture units (DFU) values, as defined by the Uniform Plumbing Code, upon the water or sewer system.
(b) The portion of the fee or charge that is charged by the City may not exceed the reasonable cost of providing this service.
17.28.080 Nonconforming Zoning Code Conditions, Building Code Violations, and Unpermitted Structures.
A. Generally. The City will not deny an ADU or JADU application due to a nonconforming zoning condition, building code violation, or unpermitted structure on the lot that does not present a threat to the public health and safety and that is not affected by the construction of the ADU or JADU.
B. Unpermitted ADUs constructed before 2018.
1. Permit to Legalize. As required by state law, the City may not deny a permit to legalize an existing but unpermitted ADU that was constructed before January 1, 2018, if denial is based on either of the following grounds:
(a) The ADU violates applicable building standards; or
(b) The ADU does not comply with state ADU law (Government Code Section 65852.2) or this ADU ordinance (Chapter 17.28).
2. Exceptions.
(a) Notwithstanding subsection (B.1) above, the City may deny a permit to legalize an existing but unpermitted ADU that was constructed before January 1, 2018, if the City makes a finding that correcting a violation is necessary to protect the health and safety of the public or of occupants of the structure.
(b) Subsection (B.1) above does not apply to a building that is deemed to be substandard in accordance with California Health and Safety Code section 17920.3.
17.28.090 Nonconforming ADUs and discretionary approval.
Any proposed ADU or JADU that does not conform to the objective standards set forth in Section 17.28.010 through Section 17.28.080 of this chapter may be allowed by the City with a conditional use permit, in accordance with the other provisions of this title. 48 Agenda Item No.: 7.I
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: JOHN SIGNO, DIRECTOR OF PLANNING & COMMUNITY SERVICES THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: FOR SECOND READING AND ADOPTION: ADOPT BY TITLE ONLY ORDINANCE NO. 382 AMENDING TITLE 15 (BUILDINGS AND
CONSTRUCTION) OF THE ROLLING HILLS MUNICIPAL CODE AND
DETERMINING THE ORDINANCE EXEMPT FROM CEQA
DATE: January 09, 2023
BACKGROUND:
On December 13, 2022, the City Council held a public hearing, took public testimony, and closed the public hearing. At the conclusion of the hearing, the City Council, on a 5-0 vote, adopted Ordinance No. 382-U and introduced Ordinance No. 382 adopting by reference Titles 26, 27, 28, 29, 30,31, and 33 of the Los Angeles County Code and making amendments to said codes, and finding the action exempt from the California Environmental Quality Act (CEQA). Ordinance No. 382-U is an urgency ordinance that took effect on January 1, 2023.
California Building Standards Commission
Every three years, the California Building Standards Commission, together with other state agencies (e.g., the Department of Housing and Community Development), updates the State’s building standards by adopting a new edition of the California Building Standards Code (“CBSC”). The CBSC consists of multiple building codes codified in Title 24 of the California Code of Regulations (these include the state building code, residential code, electrical code, plumbing code, mechanical code, fire code, energy code, and green building code). Effective January 1, 2023, these building standards apply to all building occupancies throughout the state, whether or not they are adopted by a local jurisdiction. Cities and counties, however, will typically pass ordinances adopting the CBSC by reference for the purpose of amending the state standards in accordance with local conditions and to adopt administrative provisions (e.g., fees, remedies for code violations, etc.).
Local amendments must be specific to each edition of the CBSC. State law also provides that cities and counties may adopt amendments to the state building standards only if the local governing body (i.e., the City Council) finds that such modifications or changes are reasonably necessary because of local climatic, geological or topographical conditions, and if the local 49 amendments are at least as restrictive as the state standards. (Administrative provisions that do not establish building standards may be enacted without necessity findings.) Traditionally, the City of Rolling Hills has adopted the CBSC as adopted and amended by Los Angeles County. On November 15, 2022, the County Board of Supervisors adopted the new codes with local amendments, effective January 1, 2023.
DISCUSSION:
Ordinance No. 382 largely functions to adopt the current editions of the codes, readopt previously adopted City amendments that continue to apply to local building conditions, and delete or otherwise clean up those provisions of Rolling Hills Municipal Code (RHMC) Title 15 that are obsolete or duplicative of the State and County codes.
Environmental Review
This ordinance is not a project within the meaning of Section 15378 of the California Environmental Quality Act (“CEQA”) Guidelines because it has no potential for resulting in physical change to the environment. Most of the terms of the building standards in the proposed Ordinance are dictated by the California Buildings Standards Code and county amendments to the state standards only make those modifications necessary for local regional conditions which are at least as protective of the environment as the state codes. City-specific amendments are limited to creating administrative processes for local enforcement of the state building standards. Alternatively, even if the ordinance is a project within the meaning of CEQA, its adoption is exempt from CEQA under the general rule that CEQA only applies to projects that may cause significant adverse effects on the environment. Pursuant to CEQA Guideline section 15061(b)(3), as this ordinance is largely administrative in nature, there is no possibility that the City’s action would adversely affect the environment in any manner that could be significant.
FISCAL IMPACT:
Building plan check and permit fees are paid to compensate the City for expenditures associated with these activities. As the changes in the Codes are minor, the fees collected will continue to match the expenditures, and there will be no net fiscal impact to the City.
RECOMMENDATION:
It is recommended that the City Council waive full reading and adopt Ordinance No. 382 amending Title 15 regarding Building and Construction.
ATTACHMENTS:
ATTACHMENT 1 - CL_ORD_382_BuildingCodeOrdinance_D2.pdf
50
ORDINANCE NO. 382
AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF ROLLING HILLS ADOPTING BY REFERENCE TITLE 26 OF THE LOS ANGELES COUNTY CODE INCORPORATING THE CALIFORNIA BUILDING CODE, 2022 EDITION; TITLE 27 OF THE LOS ANGELES COUNTY CODE INCORPORATING THE CALIFORNIA ELECTRICAL CODE, 2022 EDITION; TITLE 28 OF THE LOS
ANGELES COUNTY CODE INCORPORATING THE CALIFORNIA PLUMBING CODE, 2022 EDITION; TITLE 29 OF THE LOS ANGELES COUNTY CODE INCORPORATING THE CALIFORNIA MECHANICAL CODE, 2022 EDITION; TITLE 30 OF THE LOS ANGELES COUNTY CODE INCORPORATING THE CALIFORNIA RESIDENTIAL CODE, 2022 EDITION; TITLE 31 OF THE LOS
ANGELES COUNTY CODE INCORPORATING THE CALIFORNIA GREEN
BUILDING STANDARDS CODE, 2022 EDITION; TITLE 33 OF THE LOS
ANGELES COUNTY CODE INCORPORATING THE CALIFORNIA EXISTING BUILDING CODE, 2022 EDITION; MAKING AMENDMENTS TO SAID CODES;
AND FINDING THE ACTION EXEMPT FROM THE CALIFORNIA
ENVIRONMENTAL QUALITY ACT
THE CITY COUNCIL OF THE CITY OF ROLLING HILLS DOES ORDAIN AS FOLLOWS:
Section 1. Title 15 (Buildings and Construction) of the City of Rolling Hills Municipal Code is amended to read as follows:
“Title 15 – BUILDINGS AND CONSTRUCTION
Chapter 15.04 BUILDING CODE
Sections
15.04.010 Adoption of Building Code.
Except as hereinafter provided, Title 26, Building Code, of the Los Angeles County Code, as amended and in effect on January 1, 2023, adopting the California Building Code, 2022 Edition (Part 2 of Title 24 of the California Code of Regulations) is hereby adopted and incorporated by reference, as if fully set forth below, and shall be known and may be cited as the Building Code of the City of Rolling Hills.
In the event of any conflict between provisions of the California Building Code, 2022 Edition, Title 26 of the Los Angeles County Code, or any amendment to the Building Code contained in the Rolling Hills Municipal Code, the provision contained in the later listed document shall control.
A copy of Title 26 of the Los Angeles County Code and the California Building Code, 2022 Edition, have been deposited in the office of the City Clerk of the City of 51
Rolling Hills and shall be at all times maintained by the City Clerk for use and examination by the public.
15.04.020 Short title.
This chapter shall be known as the "Building Code of the City of Rolling Hills" and will be referred to herein as "this code."
15.04.030 Section 105 amended.
Section 105 of the Building Code is amended to add a new subsection 105.7 to read:
105.7 Review Hearing. The City Council of the City of Rolling Hills may conduct a public hearing to review any decision or order of the Board of Appeals, the Code Enforcement Appeals Board, or the Building Rehabilitation Appeals Board upon an affirmative vote of three members of the City Council within thirty (30) calendar days of the decision or order. The City Council may, upon conclusion of the public hearing, sustain or reverse in whole or in part any said action or order. Notice of the City Council public hearing shall be given by the City Clerk not less than ten (10) days prior to the hearing by first class mail to all property owners within 1,000 feet of the exterior boundaries of the subject property and all owners of record of the subject property at the time of mailing said notice.
15.04.040 Definitions.
Whenever any of the following names or terms are used in the California Building Code or the County of Los Angeles Building Code, each such name or term shall be deemed and construed to have the meaning ascribed to it in this section, as follows:
"Board of Appeals" means the Board of Appeals established by Section 105 of said Los Angeles County Building Code.
"Building department" means the entities charged by resolution of the City Council with the responsibility of administering the building code for the City. "Building official" means the persons charged by resolution of the City Council with the responsibility of administering the building code for the City. "City" means the City of Rolling Hills.
"City Engineer" means the persons charged by resolution of the City Council with the responsibility of performing the functions of city engineer for the City. "County," "County of Los Angeles" or "unincorporated territory of the County of Los Angeles" means the City of Rolling Hills.
52
"Electrical Code" means Chapter 15.16 of this code.
"Existing Building Code" means Chapter 15.24 of this code. "Fire Code" means Chapter 15.20 of this code.
"Fire zone" means the fire zone adopted by an ordinance creating and establishing fire zones or where no such fire zones have been adopted by the City of Rolling Hills, shall mean very high fire hazard severity zone (VHFHSZ). "General fund" means the City Treasury of the City of Rolling Hills. "Green Building Standards Code" means Chapter 15.22 of this code. "Health Code" or "Los Angeles County Health Code" means Chapter 8.04 of this code.
"Health Officer" means the Health Officer of the City of Rolling Hills. "Mechanical Code" means Chapter 15.12 of this code.
"Plumbing Code" means Chapter 15.08 of this code.
"Residential Code" means Chapter 15.18 of this code.
15.04.050 Fees.
Notwithstanding the provisions of Section 15.04.010, the Building Code is amended by increasing the amount of each and every fee set forth in the Building Code, to a sum set by resolution of the City Council, including a park and recreation fee.
15.04.060 Section 202 amended.
Section 202 of the Building Code, regarding the definition of a basement, is amended to read as follows:
BASEMENT is any floor level below the first story of the primary residence, including an attached garage. Except for walls within light wells, basement walls across any elevation may not exceed a height of five (5) feet above finished grade at any point immediately adjacent to the basement exterior, and shall have no greater than an average of two and one-half (2½) feet exterior height. Basement well(s) shall be incorporated into the overall design of the building so that it does not give an appearance of a separate story.
53
15.04.070 Section 202 amended.
Section 202 of the Building Code, regarding the definition of a story, is amended to read as follows:
STORY is that portion of a building included between the upper surface of any floor and the ceiling or roof above it. There shall be no story on top of another, except as permitted in Section 17.16.080 of the Zoning Ordinance.
15.04.080 Amending Appendix J Grading, Section J103 PERMITS REQUIRED.
Section J103.2, Exemption 8, is amended to read as follows:
8. An excavation that does not exceed 50 cubic yards and complies with one of the following conditions and as shown in Figure J103.2:
(a) Is less than 2 feet (0.6 m) in depth.
(b) Does not create a cut slope greater than 5 feet (1.5 m) measured vertically upward from the cut surface to the surface of the natural grade and is not steeper than 2 units horizontal to 1 unit vertical (50 percent slope).
Section J103.2, Exemption 9, is amended to read as follows:
9. A fill not intended to support a structure that does not obstruct a drainage course and complies with one of the following conditions and as shown in Figure J103.2:
(a) Is less than 1 foot (0.3 m) in depth and is placed on natural terrain with a slope flatter than 5 units horizontal to 1 unit vertical (20 percent slope). (b) Is less than 3 feet (0.9 m) in depth at its deepest point measured vertically upward from natural grade to the surface of the fill, does not exceed 50 cubic yards, and creates a fill slope no steeper than 2 units horizontal to 1 unit vertical (50 percent slope).
(c) Is less than 5 feet (1.5 m) in depth at its deepest point measured vertically upward from natural grade to the surface of the fill, does not exceed 20 cubic yards, and creates a fill slope no steeper than 2 units horizontal to 1 unit vertical (50 percent slope).
Section J103.6 Compliance with Zoning Code is amended to read as follows:
The Building Official may refuse to issue a grading permit for work on a site if either the proposed grading or the proposed land use for the site shown on the grading plan application does not comply with the provisions of Title 17 of the Rolling Hills Municipal Code (Zoning).
54
15.04.090 Amending Section J106.1 Maximum cut slopes.
The slope of cut surfaces shall be no steeper than is safe for the intended use and shall be no more than one unit vertical to two units horizontal (50 percent slope), unless the owner, or the owner's authorized agent, receives a variance for a steeper slope from the Planning Commission of the City of Rolling Hills and furnishes a geotechnical or an engineering geology report, or both, justifying a steeper slope. The reports must contain a statement by the Geotechnical Engineer or Engineering Geologist that the site was investigated and an opinion that a steeper slope will be stable and will not create a hazard to public or private property, in conformance with the requirements of Section 111.
Notwithstanding the provisions of this section, the Building Official may require the slope of cut surfaces to be less than 50 percent, if the Building Official finds it necessary for the stability and safety of the slope.
Exceptions:
The slope of a cut surface may be permitted to be as steep as 1.5 units horizontal to one unit vertical (67 percent) only if all of the following conditions are met:
1. It is not intended to support structures or surcharges.
2. It is approved by the Planning Commission of the City of Rolling Hills.
3. It is adequately protected against erosion.
4. It is no more than 8 feet (2438 mm) in height.
5. It is approved by the Building Official.
6. Ground water is not encountered.
15.04.100 Section J106.2 added.
Section J106 is amended to add subsection J106.2 to read as follows:
Section J106.2 DRIVEWAYS. Driveways which provide access from any lot or parcel of land to any of the private roads in the City of Rolling Hills which are maintained by the Rolling Hills Community Association shall be so constructed that the first twenty (20) feet of said driveway, measured from the edge of the paved portion of said private road, shall not be steeper in grade than seven percent (7%).
All new and relocated driveways require approval of the City of Rolling Hills Traffic Commission prior to construction.
15.04.110 Section J106.3 added.
Section J106 is amended to add subsection J106.3 to read as follows:
J106.3 BALANCED CUT AND FILL RATIO
55
Adherence to balanced cut and fill ratio is an important policy of the City and furthers the goals and objectives of its General Plan, except that export of soil generated from construction of basements and other excavation activities, promotes the preservation of natural terrain of the property. A project, which does not include excavation, may deviate from balanced cut and fill only under unusual circumstances related to the size, shape, topography or other physical conditions of the property that qualify it for a variance pursuant to Municipal Code Section
17.38.050.
1. No import of soil shall be permitted to any lot in the City, except where a variance pursuant to Chapter 17.38 has been approved.
2. No export of soil shall be permitted from any lot in the City, except where the soil is generated from an excavation activity, as defined in Municipal Code Section 17.12.050 or where a variance pursuant to Chapter 17.38 has been approved. Export of soil must comply with City refuse diversion requirements.
3. No grading plan for which a permit is required shall be approved unless the amount of soil to be cut from the site equals the amount of soil to be filled on the site, except where the soil is generated from an excavation activity or where a variance pursuant to Chapter 17.38 has been approved.
4. The City Manager, or his or her designee, may grant an exception to the requirements of parts 1 and 2 of this subsection to allow for the import or export of soil not to exceed 500 cubic yards if he or she finds, based upon written reports and other information submitted, that all of the following conditions are present:
(a) The project does not require discretionary review (a cut that is three feet or less, or a fill that is three feet or less and where the activity covers 2,000 square feet or less of surface area), and
(b) That the need to import or export the soil could not have been foreseen prior to commencement of construction.
5. The City Manager or his or her designee may grant an exception to the requirements of parts 1 and 2 of this subsection to allow for the import or export of soil not to exceed 500 cubic yards for remedial repair of the lot that has eroded, and of hillside or trail if he or she finds, based upon written reports and other information submitted, that all of the following conditions are present:
(a) The project does not require discretionary review (a cut that is three feet or less, or a fill that is three feet or less and where the activity covers 2,000 square feet or less of surface area);
(b) The import or export of soil is no greater than necessary to avoid a threat of land subsidence or other imminent danger; and 56
(c) A professionally prepared drainage plan for permanent repair shall be required if the erosion is re-occurring and if/when the amount of dirt requested, when added to the amount of dirt used in previous years, exceeds a total of 500 cubic yards.
15.04.120 Amending Section J107.6 Maximum Slope.
The slope of fill surfaces shall be no steeper than is safe for the intended use. Fill slopes steeper than 1 unit vertical to 2 units horizontal (50 percent slope) shall not be permitted unless the owner receives a variance for a steeper fill slope from the Planning Commission of the City of Rolling Hills, pursuant to the provisions of Title 17 of the Municipal Code. Such slopes shall be justified by geotechnical reports conforming with the requirements of Section 111, containing a statement by the Geotechnical Engineer that the site has been investigated and an opinion that a steeper fill slope will be stable and will not create a hazard to public or private property. Substantiating calculations and supporting data may be required where the Building Official determines that such information is necessary to verify the stability and safety of the proposed slope. The Building Official may require the fill slope to be constructed with a face flatter in slope than 2 units horizontal to 1 unit vertical (50 percent slope) if the Building Official finds it necessary for stability and safety of the slope.
15.04.130 Section J107.10 added.
Section J107, FILLS, is amended by adding subsection J107.10 to read as follows:
J107.10 BALANCED CUT AND FILL RATIO
Adherence to balanced cut and fill ratio is an important policy of the City and furthers the goals and objectives of its General Plan, except that export of soil generated from construction of basements and other excavation activities, promotes the preservation of natural terrain of the property. A project, which does not include excavation, may deviate from balanced cut and fill only under unusual circumstances related to the size, shape, topography or other physical conditions of the property that qualify it for a variance pursuant to Municipal Code Section
17.38.050.
1. No import of soil shall be permitted to any lot in the City, except where a variance pursuant to Chapter 17.38 has been approved.
2. No export of soil shall be permitted from any lot in the City, except where the soil is generated from an excavation activity, as defined in Municipal Code Section 17.12.050 or where a variance pursuant to Chapter 17.38 has been approved. Export of soil must comply with City refuse diversion requirements.
3. No grading plan for which a permit is required shall be approved unless the amount of soil to be cut from the site equals the amount of soil to be filled on 57
the site, except where the soil is generated from an excavation activity or where a variance pursuant to Chapter 17.38 has been approved.
4. The City Manager, or his or her designee, may grant an exception to the requirements of parts 1 and 2 of this subsection to allow for the import or export (other than from excavation activities), of soil not to exceed 500 cubic yards if he or she finds, based upon written reports and other information submitted, that all of the following conditions are present:
(a) Construction of a structure on the lot or parcel has commenced, (b) That the need to import or export the soil could not have been foreseen prior to commencement of construction, and
(c) That either the structure, as approved, cannot be completed without the requested import or export of soil or that an emergency condition exists due to the threat of land subsidence or other imminent danger.
5. The City Manager or his or her designee may grant an exception to the requirements of parts 1 and 2 of this subsection to allow for the import or export of soil not to exceed 500 cubic yards for remedial repair of an area of the lot that has eroded, is on a hillside or a trail if he or she finds, based upon written reports and other information submitted, that all of the following conditions are present:
(a) The project does not require discretionary review (a cut that is three feet or less, or a fill that is three feet or less and where the activity covers 2,000 square feet or less of surface area).
(b) The import or export of soil is no greater than necessary to avoid a threat of land subsidence or other imminent danger.
(c) A professionally prepared drainage plan for permanent repair shall be required if the erosion is re-occurring and if/when the amount of dirt requested, when added to the amount of dirt used in previous years, exceeds a total of 500 cubic yards.
15.04.140 Amending Section J101.2 Flood Hazard areas.
Notwithstanding the provisions of Section 15.04.010 of this chapter, the Building Code is amended by requiring that in addition to Section J101.2, all new construction and substantial improvements proposed to be built in a flood-prone area, as determined in accordance with Section 8.36.050 of the Rolling Hills Municipal Code (RHMC), is subject to the floodplain management regulations set forth in Chapter 8.36 of the RHMC. 58
15.04.150 Violations and penalties.
A. It is unlawful for any person to erect, construct, enlarge, alter, repair, move, improve, remove, convert, demolish, equip, use, occupy or maintain any building or structure or portion thereof or perform any grading in the City of Rolling Hills, or cause the same to be done, contrary to or in violation of any of the provisions of this code.
B. Penalty. Any person, firm or corporation violating any of the provisions of this code shall be guilty of a misdemeanor, and each such person shall be guilty of a separate offense for each and every day or portion thereof during which any violation is committed, continued or permitted. Upon conviction, such person may be punished by a fine not to exceed one thousand dollars or by imprisonment in the County Jail for a period of not more than six months, or by both such fine and imprisonment. The provisions of this Section are in addition to and independent of any other sanctions, penalties or costs which are or may be imposed for a violation of any of the provisions of this code.
Chapter 15.08 PLUMBING CODE
Sections:
15.08.010 Adoption of Plumbing Code.
Except as hereinafter provided, Title 28, Plumbing Code, of the Los Angeles County Code, as amended and in effect on January 1, 2023, adopting the California Plumbing Code, 2022 Edition (Part 5 of Title 24 of the California Code of Regulations), is hereby adopted and incorporated by reference, as if fully set forth below, and shall be known and may be cited as the Plumbing Code of the City of Rolling Hills.
In the event of any conflict between provisions of the California Plumbing Code, 2022 Edition, Title 28 of the Los Angeles County Code, or any amendment to the Plumbing Code contained in the Rolling Hills Municipal Code, the provision contained in the later listed document shall control.
A copy of Title 28 of the Los Angeles County Code and the California Plumbing Code, 2022 Edition, has been deposited in the office of the City Clerk of the City of Rolling Hills and shall be at all times maintained by the City Clerk for use and examination by the public.
15.08.020 Definitions.
Whenever any of the following names of terms are used in the California Plumbing Code and the Los Angeles County Plumbing Code, each such name or term shall be deemed and construed to have the meaning ascribed to it in this section, as follows:
"City" means the City of Rolling Hills.
59
"County," "County of Los Angeles" or "unincorporated territory of the County of Los Angeles" means the City of Rolling Hills.
15.08.030 Fees.
Notwithstanding the provisions of Section 15.08.010, the Plumbing Code is amended by increasing the amount of each and every fee set forth in the Plumbing Code to a sum set by resolution of the City Council.
15.08.040 Violations and penalties.
Every person, firm, or corporation violating any of the provisions of the Plumbing Code of the City of Rolling Hills shall be guilty of a misdemeanor, and each such person shall be guilty of a separate offense for each and every day or portion thereof during which any violation is committed, continued, or permitted. Upon conviction, such person may be punished by a fine not to exceed one thousand dollars or by imprisonment in the County Jail for a period of not more than six months, or by both such fine and imprisonment.
The provisions of this section are in addition to and independent of any sanctions, penalties or costs which are or may otherwise be imposed for a violation of the Rolling Hills Municipal Code.
Chapter 15.12 MECHANICAL CODE
Sections:
15.12.010 Adoption of Mechanical Code.
Except as hereinafter provided, Title 29, Mechanical Code, of the Los Angeles County Code, as amended and in effect on January 1, 2023, adopting the California Mechanical Code, 2022 Edition (Part 4 of Title 24 of the California Code of Regulations) is hereby adopted and incorporated by reference, as if fully set forth below, and shall be known and may be cited as the Mechanical Code of the City of Rolling Hills.
In the event of any conflict between provisions of the California Mechanical Code, 2022 Edition, Title 29 of the Los Angeles County Code, or any amendment to the Mechanical Code contained in the Rolling Hills Municipal Code, the provision contained in the later listed document shall control.
A copy of Title 29 of the Los Angeles County Code and the California Mechanical Code, 2022 Edition, have been deposited in the office of the City Clerk of the City of Rolling Hills and shall be at all times maintained by the City Clerk for use and examination by the public.
60
15.12.020 Definitions.
Whenever any of the following names or terms are used in the California Mechanical Code or the County of Los Angeles Mechanical Code, each such name or term shall be deemed and construed to have the meaning ascribed to it in this section, as follows:
"City" means the City of Rolling Hills.
"County," "County of Los Angeles" or "unincorporated territory of the County of Los Angeles" means the City of Rolling Hills.
15.12.030 Fees.
Notwithstanding the provisions of Section 15.12.010, the Mechanical Code is amended by increasing the amount of each and every fee set forth in the Mechanical Code to a sum set by resolution of the City Council.
15.12.040 Violations and penalties.
A. It shall be unlawful for any person, firm, or corporation to erect, install, alter, repair, relocate, add to, replace, use or maintain heating, ventilating, cooling, or refrigeration equipment in the jurisdiction, or cause the same to be done, contrary to or in violation of any of the provisions of Mechanical Code of the City of Rolling Hills. Maintenance of equipment which was unlawful at the time it was installed, and which would be unlawful under this Code if installed after the effective date of this Code, shall constitute a continuing violation of this Code.
B. Any person, firm or corporation violating any of the provisions of the Mechanical Code of the City of Rolling Hills shall be guilty of a misdemeanor, and each such person shall be guilty of a separate offense for each and every day or portion thereof during which any violation is committed, continued, or permitted. Upon conviction, such person may be punished by a fine not to exceed one thousand dollars or by imprisonment in the County Jail for a period of not more than six months, or by both such fine and imprisonment. The provisions of this section are in addition to and independent of any sanctions, penalties or costs which are or may otherwise be imposed for a violation of the Rolling Hills Municipal Code.
Chapter 15.16 ELECTRICAL CODE
Sections:
15.16.010 Adoption of Electrical Code.
Except as hereinafter provided, Title 27, Electrical Code, of the Los Angeles County Code, as amended and in effect on January 1, 2023, adopting the California 61
Electrical Code, 2022 Edition (Part 3 of Title 24 of the California Code of Regulations) is hereby adopted and incorporated by reference, as if fully set forth below, and shall be known and may be cited as the Electrical Code of the City of Rolling Hills.
In the event of any conflict between provisions of the California Electrical Code, 2022 Edition, Title 27 of the Los Angeles County Code, or any amendment to the Electrical Code contained in the Rolling Hills Municipal Code, the provision contained in the later listed document shall control.
A copy of Title 27 of the Los Angeles County Code and the California Electrical Code, 2022 Edition, have been deposited in the office of the City Clerk of the City of Rolling Hills and shall be at all times maintained by the City Clerk for use and examination by the public.
15.16.020 Definitions.
Notwithstanding the provisions of Section 15.16.010 of this chapter, whenever any of the following names or terms are used in the Electrical Code, each such name or term shall be deemed and construed to have the meaning ascribed to it in this section as follows:
"City" means the City of Rolling Hills.
"County," "County of Los Angeles" or "unincorporated area of the County of Los Angeles" means the City of Rolling Hills.
15.16.030 Electrical Code fees.
Notwithstanding the provisions of Section 15.16.010, fees for plan check, inspection, and all other miscellaneous services shall be based on the fee schedule set forth by Title 27 of the Los Angeles County Code, Fees, as approved by resolution of the City Council.
15.16.040 Violations and penalties.
Every person, firm, or corporation violating any of the provisions of the Plumbing Code of the City of Rolling Hills shall be guilty of a misdemeanor, and each such person shall be guilty of a separate offense for each and every day or portion thereof during which any violation is committed, continued, or permitted. Upon conviction, such person may be punished by a fine not to exceed one thousand dollars or by imprisonment in the County Jail for a period of not more than six months, or by both such fine and imprisonment.
The provisions of this section are in addition to and independent of any sanctions, penalties or costs which are or may otherwise be imposed for a violation of the Rolling Hills Municipal Code.
62
Chapter 15.18 RESIDENTIAL CODE
Sections:
15.18.010 Adoption of Residential Code.
Except as herein provided, Title 30, Residential Code, of the Los Angeles County Code, as amended and in effect on January 1, 2023, adopting the California Residential Code, 2022 Edition (Part 2.5 of Title 24 of the California Code of Regulations) is hereby adopted and incorporated by reference, as if fully set forth below, and shall be known and may be cited as the Residential Code of the City of Rolling Hills.
In the event of any conflict between provisions of the California Residential Code, 2022 Edition, Title 30 of the Los Angeles County Code, or any amendment to the Residential Code contained in the Rolling Hills Municipal Code, the provision contained in the later listed document shall control.
A copy of Title 30 of the Los Angeles County Code and the California Residential Code, 2022 Edition, have been deposited in the office of the City Clerk of the City of Rolling Hills and shall be at all times maintained by the City Clerk for use and examination by the public.
15.18.020 Definitions.
Notwithstanding the provisions of Section 15.18.010, names or terms that are used in this code shall be deemed and construed to have the meaning ascribed to it in Section
15.04.040 of Title 15 of the Rolling Hills Municipal Code.
15.18.040 Fees.
Notwithstanding the provisions of Section 15.18.010, the fees set forth for this code shall be the same as the fees prescribed for the Building Code in Section 15.04.050 of Title 15 of the Rolling Hills Municipal Code.
15.18.050 Violations and penalties.
A. It is unlawful for any person to erect, construct, enlarge, alter, repair, move, improve, remove, convert, demolish, equip, use, occupy or maintain any building or structure or perform any grading in the City, or cause the same to be done, contrary to or in violation of any of the provisions of the Residential Code of the City of Rolling Hills.
B. Penalty. Any person, firm or corporation violating any of the provisions of this code shall be guilty of a misdemeanor, and each such person shall be guilty of a separate offense for each and every day or portion thereof during which any violation is committed, continued or permitted. Upon conviction, such person may 63
be punished by a fine not to exceed one thousand dollars or by imprisonment in the County Jail for a period of not more than six months, or by both such fine and imprisonment. The provisions of this Section are in addition to and independent of any other sanctions, penalties or costs which are or may be imposed for a violation of any of the provisions of this code.
Chapter 15.20 FIRE CODE*
Sections:
15.20.010 Adoption of Fire Code.
Except as hereinafter provided in this chapter, California Fire Code, 2022 Edition (Part 9 of Title 24 of the California Code of Regulations), based on the International Fire Code, 2021 Edition, is hereby adopted by reference and shall constitute and may be cited as the Fire Code of the City of Rolling Hills.
In the event of any conflict between provisions of the California Fire Code, 2022 Edition, Title 32 of the Los Angeles County Code, or any amendment to the Fire Code contained in the Rolling Hills Municipal Code, the provision contained in the later listed document shall control.
A copy of the California Fire Code, 2022 Edition, has been deposited in the office of the City Clerk and shall be at all times maintained by the Clerk for use and examination by the public.
15.20.020 Short title.
This chapter shall be known as the "Fire Code of the City of Rolling Hills" and may be cited as such.
15.20.025 Very high fire hazard severity zone (VHFHSZ).
The entire City of Rolling Hills is designated as a very high fire hazard severity zone, as prescribed by the Director of California Department of Forestry and Fire Protection and as designated on a map titled City of Rolling Hills VHFHSZ dated July 1, 2008, and which shall be retained on file in the City Clerk's office at the Rolling Hills City Hall.
15.20.030 Permits.
Any permit heretofore issued by the County of Los Angeles pursuant to the Fire Code of said County, for work within the territorial boundaries of the City of Rolling Hills, shall remain in full force and effect according to its terms.
15.20.035 Reserved.
64
15.20.040 Local amendments—Reserved.
15.20.050 Violations.
Every person violating any provision of the Fire Code or of any permit or license granted hereunder, or any rule, regulation or policy promulgated pursuant hereto, is guilty of a misdemeanor unless such violation is declared to be an infraction by the Fire Code.
Each such violation is a separate offense for each and every day during any portion of which such violation is committed, continued or permitted, and conviction of any such violation shall be punishable by a fine not to exceed one thousand dollars or by imprisonment in the County Jail for a period not to exceed six months, or by both such fine and imprisonment.
15.20.060 Responsibility.
Any person who personally or through another willfully, negligently, or in violation of law sets a fire, allows a fire to be set, or allows a fire kindled or attended by such person to escape from his or her control, allows any hazardous material to be handled, stored or transported in a manner not in accordance with nationally recognized standards, allows any hazardous material to escape from his or her control, neglects to properly comply with any written notice of the Chief, or willfully or negligently allows the continuation of a violation of the Fire Code and amendments thereto is liable for the expense of fighting the fire or for the expenses incurred during a hazardous materials incident, and such expense shall be a charge against that person. Such charge shall constitute a debt of such person and is collectible by the public agency incurring such expense in the same manner as in the case of an obligation under a contract, expressed or implied.
Chapter 15.22 GREEN BUILDING STANDARDS CODE
Sections:
15.22.010 Adoption of Green Building Standards Code.
Except as hereinafter provided, Title 31, Green Building Standards Code, of the Los Angeles County Code, as amended and in effect on January 1, 2023, adopting the California Green Building Standards Code, 2022 Edition (Part 11 of Title 24 of the California Code of Regulations), is hereby adopted and incorporated by reference, as if fully set forth below, and shall be known and may be cited as the Green Building Standards Code of the City of Rolling Hills.
In the event of any conflict between provisions of the California Green Building Standards Code, 2022 Edition, Title 31 of the Los Angeles County Code, or any amendment to the Green Building Standards Code contained in the Rolling Hills Municipal Code, the provision contained in the later listed document shall control. 65
A copy of Title 31 of the Los Angeles County Code and the California Green Building Standards Code, 2022 Edition, have been deposited in the office of the City Clerk of the City of Rolling Hills and shall be at all times maintained by the City Clerk for use and examination by the public.
15.22.020 Definitions.
Notwithstanding the provisions of Section 15.22.010, names or terms that are used in this code shall be construed to have the meaning ascribed to them in the Los Angeles County Green Building Standards Code or in Section 15.04.040 of Title 15 of the Rolling Hills Municipal Code, as appropriate.
15.22.030 Water budget.
Notwithstanding the provisions of Section 15.22.010, section 4.304 of the Green Building Standards Codes is amended to add section 4.304.2 to read as follows:
4.304.2. Water Budget. A water budget shall be developed for landscape irrigation use installed in conjunction with new construction and new or redeveloped landscaping that conforms to the local water efficient landscape ordinance in Chapter 13.18 of Title 13 of the Rolling Hills Municipal Code.
15.22.040 Low-impact development.
Notwithstanding the provisions of Section 15.22.010, section 4.106.5 of the Green Building Standards Codes is amended to read as follows:
4.106.5. Low-impact development. New development or additions or alteration to existing developed sites shall comply with the Storm Water Management and Pollution Control Ordinance, Chapter 8.32 of Title 8 of the Rolling Hills Municipal Code.
15.22.050 Fees.
Notwithstanding the provisions of Section 15.22.010, the fees set forth for this code shall be the same as the fees prescribed by resolution of the City Council for the Building, Electrical, Plumbing, Mechanical, Residential, and Fire Codes of Title 15 of the Rolling Hills Municipal Code.
15.22.060 Violation and penalties.
A. It is unlawful for any person to erect, construct, enlarge, alter, repair, move, improve, remove, convert, demolish, equip, use, occupy or maintain any building or structure or perform any grading in the City, or cause the same to be done, contrary to or in violation of any of the provisions of the Green Building Standards Code of the City of Rolling Hills.
66
B. Penalty. Any person, firm or corporation violating any of the provisions of this code shall be guilty of a misdemeanor, and each such person shall be guilty of a separate offense for each and every day or portion thereof during which any violation is committed, continued or permitted. Upon conviction, such person may be punished by a fine not to exceed one thousand dollars or by imprisonment in the County Jail for a period of not more than six months, or by both such fine and imprisonment. The provisions of this Section are in addition to and independent of any other sanctions, penalties or costs which are or may be imposed for a violation of any of the provisions of this code.
Chapter 15.24 EXISTING BUILDING CODE
Sections:
15.24.010 Adoption of Existing Building Code.
Except as herein provided, Title 33, Existing Building Code of the Los Angeles County Code, in effect on January 1, 2023, adopting the California Green Building Standards Code, 2022 Edition (Part 10 of Title 24 of the California Code of Regulations), is hereby adopted and incorporated by reference, as if fully set forth below, and shall be known as the Existing Building Code of the City of Rolling Hills.
In the event of any conflict between provisions of Title 33, Existing Building Code of the Los Angeles County Code, 2022 Edition, or any amendment to the Existing Building Code contained in the Rolling Hills Municipal Code, the provision contained in the later listed document shall control.
A copy of Title 33 of the Existing Building Code and the 2022 Edition of the California Existing Building Code have been deposited in the office of the City Clerk of the City of Rolling Hills and shall be at all times maintained by the City Clerk for use and examination by the public.
15.24.020 Definitions.
Notwithstanding the provisions of Section 15.24.010, names or terms that are used in this code shall be construed to have the meaning ascribed to them in Section 15.04.040 of Title 15 of the Rolling Hills Municipal Code.
15.24.030 Fees.
Notwithstanding the provisions of Section 15.24.010, the fees set forth for this code shall be the same as the fees prescribed for the Building Code in Section 15.04.050 of Title 15 of the Rolling Hills Municipal Code.
67
15.24.040 Violations and penalties.
A. It is unlawful for any person to erect, construct, enlarge, alter, repair, move, improve, remove, convert, demolish, equip, use, occupy or maintain any building or structure or perform any grading in the City of Rolling Hills, or cause the same to be done, contrary to or in violation of any of the provisions of this code.
B. Penalty. Any person, firm or corporation violating any of the provisions of this code shall be guilty of a misdemeanor, and each such person shall be guilty of a separate offense for each and every day or portion thereof during which any violation is committed, continued or permitted. Upon conviction, such person may be punished by a fine not to exceed one thousand dollars or by imprisonment in the County Jail for a period of not more than six months, or by both such fine and imprisonment. The provisions of this Section are in addition to and independent of any other sanctions, penalties or costs which are or may be imposed for a violation of any of the provisions of this code.
Chapter 15.32 UNDERGROUND UTILITY DISTRICTS
Sections:
15.32.010 Definitions.
Whenever in this chapter the words or phrases defined in this section are used, they shall have the respective meanings assigned to them in the following definitions:
A. "Commission" means the Public Utilities Commission of the State of California.
B. "Person" means and includes individuals, firms, corporations, partnerships, and their agents and employees.
C. "Poles, overhead wires and associated overhead structures" means poles, towers, supports, wires, conductors, guys, stubs, platforms, crossarms, braces, transformers, insulators, cutouts, switches, communication circuits, appliances, attachments and appurtenances located above-ground within a district and used or useful in supplying electric, communication or similar or associated service.
D. "Underground utility district" or "district" means that area in the City within which poles, overhead wires, and associated overhead structures are prohibited as such area is described in a resolution adopted pursuant to the provisions of Section 15.32.040.
E. "Utility" includes all persons or entities supplying electric, communication or similar or associated service by means of electrical materials or devices. 68
15.32.020 Public hearing—Authorized when—Notice.
The Council may from time to time call public hearings to ascertain whether the public necessity, health, safety or welfare requires the removal of poles, overhead wires and associated overhead structures within designated areas of the City and the underground installation of wires and facilities for supplying electric, communication or similar or associated service. The City Clerk shall notify all affected property owners as shown on the last equalized assessment roll and utilities concerned by mail of the time and place of such hearings at least ten days prior to the date thereof. Each such hearing shall be open to the public and may be continued from time to time. At each such hearing all persons interested shall be given an opportunity to be heard. The decision of the Council shall be final and conclusive.
15.32.030 Public hearing—Consultation.
Prior to holding such public hearing, the City Engineer shall consult with all affected utilities and shall prepare a report for submission at such hearing containing, among other information, the extent of such utilities' participation and estimates of the total costs to the city and affected property owners. Such report shall also contain an estimate of the time required to complete such underground installation and removal of overhead facilities.
15.32.040 Council resolution-Procedure.
If, after any such public hearing, the Council finds that the public necessity, health, safety or welfare requires such removal and such underground installation within a designated area, the Council shall, by resolution, declare such designated area an underground utility district and order such removal and underground installation. Such resolution shall include a description of the area comprising such district and shall fix the time within which such removal and underground installation shall be accomplished and within which affected property owners must be ready to receive underground services. A reasonable time shall be allowed for such removal and underground installation, having due regard for the availability of labor, materials and equipment necessary for such removal and for the installation of such underground facilities as may be occasioned thereby.
15.32.050 Maintaining overhead structures prohibited when.
Whenever the Council creates an underground utility district and orders the removal of poles, overhead wires and associated overhead structures therein as provided in Section 15.32.040, it is unlawful for any person or utility to erect, construct, place, keep, maintain, continue, employ or operate poles, overhead wires and associated overhead structures in the district after the date when said overhead facilities are required to be removed by such resolution, except as said overhead facilities may be required to furnish service to an owner or occupant of property prior to the performance by such owner or occupant to continue to receive utility service as provided in Section 15.32.100, and for 69
such reasonable time required to remove said facilities after said work has been performed, and except as otherwise provided in this chapter.
15.32.060 Emergency overhead structures.
Notwithstanding the provisions of this chapter, overhead facilities may be installed and maintained for a period not to exceed ten days without authority of the City Manager in order to provide emergency service. The City Manager may grant special permission on such terms as the City Manager may deem appropriate, in cases of unusual circumstances, without discrimination as to any person or utility, to erect, construct, install, maintain, use or operate poles, overhead wires and associated overhead structures.
15.32.070 Council resolution—Exceptions authorized.
In any resolution adopted pursuant to Section 15.32.040, the City may authorize any or all of the following exceptions:
A. Any municipal facilities or equipment installed under the supervision and to the satisfaction of the City Engineer;
B. Poles or electroliers used exclusively for street lighting; C. Overhead wires (exclusive of supporting structures) crossing any portion of a district within which overhead wires have been prohibited, or connecting to buildings on the perimeter of a district, which such wires originate in an area from which poles, overhead wires and associated overhead structures are not prohibited;
D. Poles, overhead wires and associated overhead structures used for the transmission of electric energy at nominal voltages in excess of 34,500 volts;
E. Overhead wires attached to the exterior surface of a building by means of a bracket or other fixture and extending from one location of the building to another location on the same building or to an adjacent building without crossing any public street;
F. Antennae, associated equipment and supporting structures used by a utility for furnishing communication services;
G. Equipment appurtenant to underground facilities, such as surface-mounted transformers, pedestal-mounted terminal boxes and meter cabinets, and concealed ducts.
H. Temporary poles, overhead wires and associated overhead structures used or to be used in conjunction with construction projects. 70
15.32.080 Notice to property owners and utility companies.
A. Within ten days after the effective date of a resolution adopted pursuant to Section 15.32.040, the City Clerk shall notify all affected utilities and all persons owning real property within the district created by said resolution of the adoption thereof. The City Clerk shall further notify such affected property owners of the necessity that if they or any person occupying such property desire to continue to receive electric, communication, or similar or associated service, they or such occupant shall provide all necessary facility changes on their premises so as to receive such service from the lines of the supplying utility or utilities at a new location.
B. Notification by the City Clerk shall be made by mailing a copy of the resolution adopted pursuant to Section 15.32.040, together with a copy of this chapter, to affected property owners as such are shown on the last equalized assessment roll and to the affected utilities.
15.32.090 Responsibility of utility companies.
If underground construction is necessary to provide utility service within a district created by any resolution adopted pursuant to Section 15.32.040, the supplying utility shall furnish that portion of the conduits, conductors and associated equipment required to be furnished by it under its applicable rules, regulations and tariffs on file with the Commission.
15.32.100 Responsibility of property owners—Notice.
Every person owning, operating, leasing, occupying or renting a building or structure within a District shall construct and provide that portion of the service connection on his property between the facilities referred to in Section 15.32.090 and the termination facility on or within said building or structure being served. If the above is not accomplished by any person within the time provided for in the resolution enacted pursuant to Section 15.32.040, the City Engineer shall give, notice in writing to the person in possession of such premises, and a notice in writing to the owner thereof as shown on the last equalized assessment roll, to provide the required underground facilities within ten days after receipt of such notice.
15.32.110 Notice—Service.
The notice to provide the required underground facilities may be given either by personal service or by mail. In case of service by mail on either of such persons, the notice must be deposited in the United States mail in a sealed envelope with postage prepaid, addressed to the person in possession of such premises at such premises, and the notice must be addressed to the owner thereof as such owner's name appears, and must be addressed to such owner's last known address as the same appears on the last equalized assessment roll, and when no address appears, to General Delivery, City of 71
Rolling Hills, California. If notice is given by mail, such notice shall be deemed to have been received by the person to whom it has been sent within forty-eight hours after the mailing thereof. If notice is given by mail to either the owner or occupant of such premises, the City Engineer shall, within forty-eight hours after the mailing thereof, cause a copy thereof, printed on a card not less than eight inches by ten inches in size to be posted in a conspicuous place on said premises.
15.32.120 Notice—Form.
The notice given by the City Engineer to provide the required underground facilities shall particularly specify what work is required to be done, and shall state that if said work is not completed within thirty days after receipt of such notice, the City Engineer will provide such required underground facilities, in which case the cost and expense thereof will be assessed against the property benefited and become a lien upon such property.
15.32.130 Work by City Engineer—Assessment of costs.
If upon the expiration of the thirty-day period the required underground facilities have not been provided, the City Engineer shall forthwith proceed to do the work; provided, however, if such premises are unoccupied and no electric or communications services are being furnished thereto, the City Engineer may authorize the disconnection and removal of any and all overhead service wires and associated facilities supplying utility service to said property. Upon completion of the work by the City Engineer, he shall file a written report with the City Council setting forth the fact that the required underground facilities have been provided and the cost thereof, together with a legal description of the property against which such cost is to be assessed. The Council shall thereupon fix a time and place for hearing protests against the assessment of the cost of such work upon such premises, which said time shall not be less than ten days thereafter.
15.32.140 Assessment—Hearing—Notice.
The City Engineer shall forthwith, upon the time for hearing such protests having been fixed, give a notice in writing to the person in possession of such premises, and a notice in writing thereof to the owner thereof, in the manner provided in this chapter for the giving of the notice to provide the required underground facilities, of the time and place that the Council will pass upon such report and will hear protests against such assessment. Such notice shall also set forth the amount of the proposed assessment.
15.32.150 Assessment—Hearing—Decision.
Upon the date and hour set for the hearing of protests, the Council shall hear and consider the report and all protests if there be any, and then proceed to affirm, modify or reject the assessment.
72
15.32.160 Assessment—Lien.
If any assessment is not paid within the five days after its confirmation by the Council, the amount of the assessment shall become a lien upon the property against which the assessment is made by the City Engineer, and the City Engineer is directed to turn over to the Assessor and Tax Collector a notice of lien of each of said properties on which the assessment has not been paid, and the Assessor and Tax Collector shall add the amount of said assessment to the next regular bill for taxes levied against the premises upon which said assessment was not paid. Said assessment shall be due and payable, and if not paid when due and payable, shall bear interest at the rate of six percent per annum.
15.32.170 Responsibility of City.
The City shall remove at its own expense all City-owned equipment from all poles required to be removed under this chapter in ample time to enable the owner or user of such poles to remove the same within the time specified in the resolution enacted pursuant to Section 15.32.040.
15.32.180 Extension of time.
In the event that any act required by this chapter or by a resolution adopted pursuant to Section 15.32.040 cannot be performed within the time provided on account of shortage of materials, war, restraint by public authorities, strikes, labor disturbances, civil disobedience, or any other circumstances beyond the control of the contractor, then the time within which such act will be accomplished shall be extended for a period equivalent to the time of such limitation.
15.32.190 Violation—Penalty.
It is unlawful for any person to violate any provision or to fail to comply with any requirement of this chapter. Any person violating any provision of this chapter or failing to comply with any of its requirements shall be deemed guilty of a misdemeanor and upon conviction thereof shall be punishable by a fine or not more than one thousand dollars or by imprisonment in County Jail for a period not exceeding six months, or by both such fine and imprisonment. Each such person shall be guilty of a separate offense for each and every day during any portion of which any violation of any provision of this chapter is committed, continued or permitted by such person and shall be punishable accordingly. 73
Chapter 15.36 HOURS OF CONSTRUCTION
Sections:
15.36.010 Work of improvement defined.
For the purpose of this chapter, "work of improvement" includes but is not restricted to the construction, alteration, addition, or the repair, in whole or in part, of any building, structure, bridge, ditch, pipeline, tunnel, fence, or road; the cutting or removal of weeds, trees and grass; the seeding, sodding or planting of any lot or tract of land for landscaping purposes; the filling, levelling, grading of any lot or tract of land; or the crushing of rock or the hauling of any material to be used or removed in connection with any of the foregoing; the demolition of buildings; or the removal of buildings.
15.36.020 Hours restricted.
There shall be no work of improvement or the operation of mechanical equipment used in connection with work of improvement within the territorial limits of the City except on Monday through Saturday of each week, commencing at the hour of seven a.m. and ending at the hour of six p.m. on each day.
15.36.030 Exceptions.
The provisions of this chapter shall not apply to residents of the City who are the record owners of land in the City or who are the lessees of the record owners of land in the City.
Chapter 15.40 GEOLOGICAL INVESTIGATIONS AND REPORTS REQUIRED Sections:
15.40.010 Requirements.
The requirements provided for in this chapter are in addition to any and all other requirements relating to expansive soils and geological inspections and reports required by the building code of the City or any other ordinance of the City.
15.40.020 Authority—Procedure.
A. No building (as defined in the Los Angeles County Building Laws) for which a building or grading permit is required by the building code of the City, shall be issued by the City Engineer if he, and/or the City Council, is of the opinion that a potentially serious geological condition may exist on the land on which the proposed building is to be constructed, or the proposed grading is to be performed, until a geological report prepared by a geologist registered by the State is delivered 74
to the City Engineer by the applicant for the building or grading permit. The report shall include, among other things, test borings or excavations.
B. If said geological report, in the opinion of the City Engineer, indicates a potential serious geological condition, the City Engineer shall have the authority to employ an independent geologist registered by the State, to prepare and provide him with an independent geological report of the land on which the proposed building is to be constructed or the grading is proposed to be performed, and if necessary, to require additional test borings or excavations to be made by an independent testing service, the depth and accuracy of which shall be approved by said registered geologist.
C. The City Engineer shall also have authority to submit samples of any and all test borings or excavations to an independent qualified geological laboratory for analysis and report.
D. The geological report prepared by the independent registered geologist shall recommend corrective action which is designed to prevent the displacement or slippage of the land.
15.40.030 Corrective action required when.
As a condition to the issuance of a permit by the City Engineer of the City, the corrective action or procedures recommended in the geological report shall be incorporated in the proposed construction or grading for which the permit has been applied.
15.40.040 Assessment of costs.
All expenses incurred by the applicant in complying with the provisions of this chapter shall be paid for by the applicant and shall be in addition to all other charges or fees levied, assessed or charged by the City in connection with the issuance of a building or grading permit.”
Section 2. All inconsistencies between the Building Code, Electrical Code, Mechanical Code, Plumbing Code, Residential Code, Green Building Code, and Existing Building Code, as adopted by this ordinance and Parts 2, 2.5, 3, 4, 5, 10, and 11 of the California Code of Regulations, are changes, modifications, amendments, additions, or deletions thereto authorized by California Health and Safety Code Sections 17958 and 17958.7.
Section 3. Justifications for Local Amendments. The City Council hereby finds that the changes and modifications to the California Building Code, Plumbing Code, Mechanical Code, Electrical Code, Residential Code, Green Building Code, and Existing Building Code enacted by this ordinance are reasonably necessary because of the City's local climate, characterized by hot, dry summers, often resulting in drought conditions, followed by strong Santa Ana winds, often resulting in hazardous fire conditions, and 75
heavy winter rains, often resulting in expansive soil conditions; the City's geological characteristics in that the area is characterized by geological instability; location in Southern California; and the relatively flat topography of the City.
The City Council hereby finds that the modifications to the State Building Code in Title 26 of the Los Angeles County Code are reasonably necessary because of the local climatic, geological, and topographical conditions within the City of Rolling Hills. Further, the modifications to the Building, Electrical, Mechanical, Plumbing, Green Building Standards, Residential, and Existing Building Codes in Titles 26, 27, 28, 29, 30, 31 and 33 of the Los Angeles County Code are administrative in nature and are necessary to allow the uniform application of the codes by procedures suited to the size and nature of the City's staff and administrative agencies by means suited to the City's experience with local climatic, geological, and topographical conditions and to provide sufficient staff support for the time-consuming inspections and analysis required by the City's fire and geological hazards.
Section 4. To the extent the provisions of this ordinance are substantially the same as previous provisions of the Rolling Hills Municipal Code, these sections shall be construed as continuations of those provisions and not as new enactments.
Section 5. Severability. If any section, subsection, subdivision, paragraph, sentence, clause, or phrase of this ordinance or any part hereof is for any reason held to be invalid by a court of competent jurisdiction, such invalidity shall not affect the validity of the remaining portions of this ordinance or any part thereof. The City Council of the City of Rolling Hills hereby declares that it would have passed each section, subsection, subdivision, paragraph, sentence, clause, or phrase hereof, irrespective of the fact that any one or more sections, subsections, subdivisions, paragraphs, sentences, clauses, or phrases be declared invalid.
Section 6. California Environmental Quality Act. The City Council finds that this ordinance is not a project within the meaning of Section 15378 of the California Environmental Quality Act (“CEQA”) Guidelines because it has no potential for resulting in physical change to the environment. Most of the terms of the building standards adopted herein are dictated by the California Buildings Standards Code and county amendments to the state standards only make those modifications necessary for local regional conditions which are at least as protective of the environment as the state codes.
City-specific amendments are limited to creating administrative processes for local enforcement of the state building standards. Alternatively, even if the ordinance is a project within the meaning of CEQA, its adoption is exempt from CEQA under the general rule that CEQA only applies to projects that may cause significant adverse effects on the environment. CEQA Guideline section 15061(b)(3). As this ordinance is largely administrative in nature, there is no possibility that the City’s action would adversely affect the environment in any manner that could be significant.
76
Section 7. Effective Date. This Ordinance shall take effect 30 days after its passage and adoption pursuant to California Government Code section 36937 and shall apply to all projects submitted to the City for plan check and/or permit application on or after that date.
PASSED, APPROVED, AND ADOPTED this 9th day of January, 2023. ________________________________
MAYOR
ATTEST
City Clerk
77 Agenda Item No.: 7.J
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: VANESSA HEVENER, SENIOR MANAGEMENT ANALYST
THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: ADOPT RESOLUTION NO. 1321 OF THE CITY COUNCIL OF THE CITY
OF ROLLING HILLS AUTHORIZING SUBMITTAL OF APPLICATIONS
FOR THE CALIFORNIA DEPARTMENT OF RESOURCES RECYCLING
A N D RECOVERY (CALRECYCLE) PAYMENT PROGRAMS AND
RELATED AUTHORIZATIONS
DATE: January 09, 2023
BACKGROUND:
On January 24, 2022 the City Council approved Resolution No. 1286 which was intended to be a multi-year resolution to allow the City to apply for a variety of grants and programs administered by the Department of Resources Recycling and Recovery (CalRecycle) including the annual Beverage Container Recycling City/County Payment Program.
On December 5, 2022, Staff submitted the application for the annual Beverage Container Recycling City/County Payment Program. Shortly thereafter, Staff was notified that Resolution No. 1286 did not include a ‘valid until rescinded’ clause which if that clause was not included, the resolution would be only valid for one year from the date of adoption. In order to approve the City's application, CalRecycle requires an adoption of a new Resolution before the grant deadline of January 17, 2023.
The City of Rolling Hills is eligible for a $5,000 grant award upon completion of the funding application. The Beverage Container Recycling City/County Payment Program has an Expenditure Period of two years after awarding with term date of March 1, 2025. The Program has a variety of eligible activities and options to allow jurisdictions to utilize the funds most appropriately.
DISCUSSION:
Resolution No. 1321 includes language that will allow the City to apply for CalRecycle grants for multiple years.
FISCAL IMPACT:
The grant has no fiscal impact to the General Fund.
78 RECOMMENDATION:
Approve as presented.
ATTACHMENTS:
ResolutionNo1321_CalRecycleGrant.pdf
79 1
RESOLUTION NO. 1321
A RESOLUTION OF THE CITY COUNCIL OF
THE CITY OF ROLLING HILLS AUTHORIZING
SUBMITTAL OF APPLICATIONS FOR THE
CALIFORNIA DEPARTMENT OF RESOURCES
RECYCLING AND RECOVERY (CALRECYCLE)
PAYMENT PROGRAMS AND RELATED
AUTHORIZATIONS
THE CITY COUNCIL OF THE CITY OF ROLLING HILLS, CALIFORNIA DOES HEREBY RESOLVE, DECLARE, DETERMINE, AND ORDER AS FOLLOWS:
Section 1. Recitals.
A. Public Resources Code Sections 48000 et seq., 14581, and 42023.1(g) authorize the Department of Resources Recycling and Recovery (“CalRecycle”) to administer various payment programs to make payments to qualifying jurisdictions; and B. In furtherance of this authority, CalRecycle is required to establish procedures governing the administration of the payment programs; and C. CalRecycle’s procedures for administering payment programs require, among other things, an applicant’s governing body to declare by resolution certain authorizations related to the administration of the payment program; and D. The City Council of the City of Rolling Hills (“City”) desires to authorize the City Manager or her designee to submit applications to CalRecycle for any payment program for which it is eligible and execute all documents necessary to implement and secure payments thereunder.
Section 2. The City of Rolling Hills is authorized to submit applications to CalRecycle for payment programs for which it is eligible.
Section 3. The City Manager or her designee is authorized to execute in the name of the City of Rolling Hills all documents necessary to implement and secure payments under the payment programs for which it is eligible.
Section 4. This Resolution shall take effect immediately upon its adoption by the City Council and is in effect until rescinded by the City Council. The City Clerk shall certify to the passage and adoption of this Resolution and enter it into the book of original resolutions.
80 2
PASSED, APPROVED, AND ADOPTED this 9th day of January 2023. ______________________________
PAT WILSON
MAYOR
ATTEST:
___________________________
CHRISTIAN HORVATH
CITY CLERK
81 3
STATE OF CALIFORNIA )
COUNTY OF LOS ANGELES ) §§
CITY OF ROLLING HILLS )
The foregoing Resolution No. 1321 entitled:
A RESOLUTION OF THE CITY COUNCIL OF
THE CITY OF ROLLING HILLS AUTHORIZING
SUBMITTAL OF APPLICATIONS FOR THE
CALIFORNIA DEPARTMENT OF RESOURCES
RECYCLING AND RECOVERY (CALRECYCLE)
PAYMENT PROGRAMS AND RELATED
AUTHORIZATIONS
was approved and adopted at a regular meeting of the City Council on the 9th day of January 2023, by the following roll call vote:
AYES:
NOES:
ABSENT:
ABSTAIN:
___________________________
CHRISTIAN HORVATH
CITY CLERK
82 Agenda Item No.: 11.A
Mtg. Date: 01/09/2023
TO: HONORABLE MAYOR AND MEMBERS OF THE CITY COUNCIL
FROM: ELAINE JENG, CITY MANAGER
THRU: ELAINE JENG P.E., CITY MANAGER
SUBJECT: APPROVE PLANS AND SPECIFICATIONS AND AUTHORIZE
SOLICITATION FOR CONSTRUCTION BIDS FOR THE CITY HALL
HEATING, VENTILATION AND AIR CONDITIONING (HVAC) PROJECT
AND FINDING THE SAME EXEMPT FROM THE CALIFORNIA
ENVIRONMENTAL QUALITY ACT.
DATE: January 09, 2023
BACKGROUND:
Since late July 2022, City Hall operated without proper ventilation. At the October 10, 2022 City Council meeting, S&K Consulting Services was hired to assess the condition of the City Hall Heating, Ventilation and Air Conditioning (HVAC) system and provide an engineering design for a functioning system.
DISCUSSION:
In late November 2022, S&K Consulting Services completed the engineering design and submitted plans for permitting with the Los Angeles County Building and Safety. Per the current Los Angeles County Building Code, S&K Consulting was able to determine that the scope of work is an HVAC replacement/repair project.
S&K Consulting Services reported that the existing equipment includes a pair of furnaces that are twinned (interlocked to supply the same duct) with two cooling coils connected to a single commercial outdoor package unit. The size of the furnaces are no longer manufactured and twinning is no longer common practice with ultra-low nox systems. Most of the ductwork has been damaged beyond repair and sections are in shambles above the ceiling.
City Hall is split into two zones in this context. Zone 1 is comprised of the individual offices, and the lobby. Zone 2 is comprised of the Council Chambers. The new design will addressing existing imbalance of airflow and improve temperature control by splitting Zone 1 into two zones where the lobby, reception area and hallway will be on a separate thermostat.
S&K Consulting Services also specified new HVAC equipment with higher efficiencies and the lowest emissions. Several pieces of equipment will need to be placed outside of City Hall, at 83 the existing recycling center.
Alan Palermo Consulting, the City's Project Manager coordinated information exchange between S&K Consulting Services, and the City Hall ADA Improvement Project design team to ensure that the HVAC project makes provisions for the future condition to be improved by the ADA project.
Plans were submitted to Los Angeles County in November 2022 and approved in December.
The plans have been revised to (Revision No. 1) to include information/address existing hazardous materials. S&K consulting is confirming if this plan revision requires Los Angeles County plan review. The plans and specifications attached include Revision No. 1.
The engineer's estimate to the HVAC project is $250,185.
If the City Council authorizes staff to solicit construction bids, staff anticipates the bid opening in mid February 2022 and construction to commence in mid March 2022. Depending on the lead time for the equipment, construction duration can vary between two to five months.
ENVIRONMENTAL REVIEW
The solicitation for bids does not constitute a Project as defined under the California Environmental Quality Act (“CEQA”).
Further, the solicitation for bids for HVAC at City Hall is exempt from CEQA pursuant to section 15301 of the CEQA Guidelines (Existing facilities) in that it will replace already existing equipment at City Hall with upgraded and more energy efficient versions.
FISCAL IMPACT:
The failure of the City Hall HVAC system was unanticipated; the project was not budgeted in the Fiscal Year 2022-2023 adopted budget. If the City Council approves the project to move forward, the General Fund Reserves would be need to fund the project, in the amount of $250,185. This amount could change depending on construction bids received.
RECOMMENDATION:
Approve as presented.
ATTACHMENTS:
CL_AGN_230109_CC_HVAC_UpgradeCostEstimate.pdf
CL_AGN_230109_CC_HVAC_RepairSpecs.pdf
CL_AGN_230109_CC_HVAC_RepairDrawings.pdf
CL_AGN_230109_CC_HVAC_PublicComment01_Redacted.pdf
84 % TOTAL
SUMMARY
DIVISION 01 11,168.75
DIVISION 02 19,500.00
DIVISION 03 10,500.00
DIVISION 23 121,560.67
DIVISION 26 16,800.00
SUBTOTAL 179,529.42
8.0% 14,363.00
SUBTOTAL 193,892.42
10.0% 19,390.00
SUBTOTAL 213,282.00
2.0% 4,266.00
SUBTOTAL 217,548.00
15.0% 32,633.00
SUBTOTAL 250,181.00
TOTAL 250,181.00
City of Rolling Hills
Status of Design: Final ESTIMATED BY Samuel Simon
COST ESTIMATE SUMMARY
1 YEAR ESCALATION
HEATING, VENTILATING, AND AIR CONDITIONING
ELECTRICAL
BONDS AND INSURANCE
CONTINGENCY
OVERHEAD AND PROFIT
Rolling Hills City Hall HVAC Repair Project CLIENT
ENGINEERING ESTIMATE
GENERAL CONDITIONS
EXISTING CONDITIONS
CONCRETE
ITEM DESCRIPTION
DATE PREPARED
PROJECT NO.
12/22/2022
0092226
85 NUMBER UNIT UNIT COST TOTAL UNIT COST TOTAL UNIT COST TOTAL 01 GENERAL CONDITIONS 11,168.75
Mobilization 1.00 LS 3,200.00 3,200.00
Superintendent 1.50 MO 2,012.50 3,018.75
Temporary Barriers and Fences 1.00 LS 1,250.00 1,250.00 Scissor Lift Rental 1.00 MO 1,000.00 1,000.00
General Conditions Allowances 1.00 LS 2,700.00 2,700.00 02 EXISTING CONDITIONS 19,500.00
General Demolition 1.00 LS 12,500.00 12,500.00
Abatement 1.00 LS 7,000.00 7,000.00
03 CONCRETE 10,500.00
Concrete Equipment Pads 3.00 EA 3,500.00 10,500.00
23 HEATING, VENTILATING, AND AIR CONDITIONING 121,560.67 High Efficiency, Ultra-Low Nox, Furnace Units 3.00 EA 7,929.00 23,787.00 640.00 1,920.00 8,569.00 25,707.00 High Efficiency Air Conditioner 3.00 EA 4,446.00 13,338.00 640.00 1,920.00 5,086.00 15,258.00 Refrigerant Cooling Coils 3.00 EA 1,719.00 5,157.00 640.00 1,920.00 2,359.00 7,077.00 High Performance Economizer 3.00 EA 2,904.00 8,712.00 640.00 1,920.00 3,544.00 10,632.00 Refrigerant Piping 3.00 EA 1,100.00 3,300.00 1,600.00 4,800.00 2,700.00 8,100.00 Natural Gas Piping 3.00 EA 750.00 2,250.00 640.00 1,920.00 1,390.00 4,170.00 Controls 3.00 LS 7,500.00 22,500.00
Duct, Insulation, Hanging, and Bracing 1.00 LS 16,200.00 16,200.00 Registers & Dampers 10.00 EA 375.00 3,750.00 106.67 1,066.67 481.67 4,816.67 Testing, Adjusting, & Balancing 1.00 LS 4,300.00 4,300.00
ITEM DESCRIPTION QUANTITY MATERIAL COST LABOR COST ENGINEERING ESTIMATE 12/22/2022 COST ESTIMATE
Rolling Hills City Hall HVAC Repair Project
DATE PREPARED
PROJECT NO.
CLIENT
Status of Design: Final ESTIMATED BY
0092226
City of Rolling Hills
Samuel Simon
86 NUMBER UNIT UNIT COST TOTAL UNIT COST TOTAL UNIT COST TOTAL
ITEM DESCRIPTION QUANTITY MATERIAL COST LABOR COST ENGINEERING ESTIMATE 12/22/2022 COST ESTIMATE
Rolling Hills City Hall HVAC Repair Project
DATE PREPARED
PROJECT NO.
CLIENT
Status of Design: Final ESTIMATED BY
0092226
City of Rolling Hills
Samuel Simon
Air Duct Cleaning 1.00 LS 2,800.00 2,800.00
26 ELECTRICAL 16,800.00
Electrical Power for HVAC 3.00 LS 5,600.00 16,800.00
100
87 Prepared by:
December 28, 2022
385 Van Ness Ave, Ste 270
Torrance, CA 90501
t. (310) 494-6910
e. [email protected]
S&K No. 092226
SPECIFICATIONS
Rolling Hills City Hall HVAC REPAIR
ROLLING HILLS , CA
Prepared for:
City of Rolling Hills
No. 2 Portuguese Bend Rd
Rolling Hills, CA 90274
t. (310) 377-1521
f. (310) 377-7288
88 S&K Consulting Services, LLC 2233 Via Fernandez, Palos Verdes Estates, CA 90274 o. 310 494 6910 e. [email protected] www.skcsi.com
THIS PAGE IS INTENTIONALLY LEFT BLANK
89 S&K Consulting Services, LLC The City of Rolling Hills S&K No. 092226 Rolling Hills City Hall HVAC Repair
TABLE OF CONTENTS 1
TABLE OF CONTENTS
DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS
(NOTE: TO BE FURNISHED BY OWNER)
000105 Certifications Page
003126 Existing Hazardous Material Information
DIVISION 01 - GENERAL REQUIREMENTS
(NOTE: SOME SECTIONS TO BE FURNISHED BY OWNER)
012500 Substitution Procedures
013300 Submittal Procedures
013516 Alteration Project Procedures
014000 Quality Requirements
017300 Execution
017419 Construction Waste Management and Disposal
017700 Closeout Procedures
017823 Operation and Maintenance Data
017839 Project Record Documents
017900 Demonstration and Training
DIVISION 02 - EXISTING CONDITIONS
024119 Selective Demolition
DIVISION 03 - CONCRETE
033000 Cast-In-Place Concrete
DIVISION 23 - HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) 230130.52 Existing HVAC Air Distribution System Cleaning 230529 Hangers and Supports for HVAC Piping and Equipment 230548 Vibration and Seismic Controls for HVAC
230553 Identification for HVAC Piping and Equipment
230593 Testing, Adjusting, and Balancing for HVAC
230713 Duct Insulation
230719 HVAC Piping Insulation
230923.27 Temperature Instruments
231123 Facility Natural-Gas Piping
232300 Refrigerant Piping
233113 Metal Ducts
90 S&K Consulting Services, LLC The City of Rolling Hills S&K No. 092226 Rolling Hills City Hall HVAC Repair
TABLE OF CONTENTS 2
233300 Air Duct Accessories
233713.23 Registers and Grilles
235416.13 Gas-Fired Furnaces
236313 Air-Cooled Refrigerant Condensers
238216.13 Refrigerant Air Coils
DIVISION 26 - ELECTRICAL
260519 Low-Voltage Electrical Power Conductors and Cables 260523 Control-Voltage Electrical Power Cables
260529 Hangers and Supports for Electrical Systems
260533 Raceways and Boxes for Electrical Systems
260553 Identification for Electrical Systems
262816 Enclosed Switches and Circuit Breakers
END OF TABLE OF CONTENTS
91 S&K Consulting Services, LLC The City of Rolling Hills S&K No. 092226 Rolling Hills City Hall HVAC Repair
CERTIFICATIONS PAGE 000105 - 1
DOCUMENT 000105 - CERTIFICATIONS PAGE
PROJECT TITLE: Rolling Hills City Hall HVAC Repair
CLIENT AGENCY: City of Rolling Hills
LOCATION: 2 Portuguese Bend Rd
Rolling Hills, CA 90274
PROJECT NUMBER: S&K #092226
OWNER: City of Rolling Hills
OWNER’S REPRESENTATIVE: Elaine Jeng
City of Rolling Hills
2 Portuguese Bend Rd, Rolling Hills, CA 90274
Telephone Number: (310) 377-1521
CONSULTANT: S&K Consulting Services
Samuel Simon, PE
MECHANICAL & PLUMBING
Sevag Avanessian, PE
ELECTRICAL ENGINEER
M 40818
92 S&K Consulting Services, LLC The City of Rolling Hills S&K No. 092226 Rolling Hills City Hall HVAC Repair
CERTIFICATIONS PAGE 000105 - 2
THIS PAGE IS INTENTIONALLY LEFT BLANK
93 S&K Consulting Services, LLC The City of Rolling Hills S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXISTING HAZARDOUS MATERIAL INFORMATION 003126 - 1
DOCUMENT 003126 - EXISTING HAZARDOUS MATERIAL INFORMATION
1.1 EXISTING HAZARDOUS MATERIAL INFORMATION
A. This Document with its referenced attachments is part of the Procurement and Contracting Requirements for Project. They provide Owner's information for Bidders' convenience and are intended to supplement rather than serve in lieu of Bidders' own investigations. They are made available for Bidders' convenience and information, but are not a warranty of existing conditions.
This Document and its attachments are not part of the Contract Documents.
B. An existing asbestos report for Project, prepared by Ellis Environmental Management, Inc, dated November 10, 2022, is available for viewing as appended to this Document.
C. An existing lead report for Project, prepared by Ellis Environmental Management, Inc, dated November 10, 2022, is available for viewing as appended to this Document.
END OF DOCUMENT 003126
94 Ellis
Hazardous Materials Assessment
o Asbestos
o Lead
Rolling Hills City Hall
2 Portuguese Bend Road
Rolling Hills, CA 90274
Sampling Date: October 28, 2022
Prepared for:
Elaine Jeng, City Manager
Rolling Hills
2 Portuguese Bench Road
Rolling Hills, CA 90274
Prepared by:
Ellis Environmental Management, Inc.
430 Silver Spur Road, Suite 201
Rancho Palos Verdes, CA 90275
310 544 1837 / www.ellisenvironmental.com
Report Date: November 10, 2022
Ellis Project No: 22-452
95 Ellis
Terms of Use
This investigation and subsequent report have been performed and prepared for the exclusive of:
The City of Rolling Hills
by Ellis Environmental Management, Inc. Ellis will distribute any information regarding this assessment and report only upon the request of the client. This report is based upon data and information obtained during the site visits performed by Ellis personnel for the property identified herein and is based solely upon the condition of the property on the date of such inspection, supplemented by information and data obtained by Ellis and described herein. Information presented is based on professional interpretation of data available as of the date of the report. Physical materials testing (radon) was not performed as part of this investigation.
In evaluating the property, Ellis has relied in good faith upon representations and information furnished by individuals and agencies noted in the report with respect to operations and existing property conditions, and the historic uses of the property to the extent that they have not been contradicted by data obtained from other sources. Use of this report indicates acceptance and agreement that Ellis will incur no responsibility or liability for any loss, injury, claim or damage arising directly or indirectly from any use or reliance on this report, regardless of whether claimed loss, injury, claim or damage was caused by the deficiency, misstatements, omissions, misinterpretations, or fraudulent acts of persons interviewed. Ellis has performed this work, made findings, and proposed recommendations described in this report in accordance with generally accepted environmental science practices in effect at the time the work was performed and within the time frames requested by client. Additional information received following issuance of the report may alter initial findings and recommendations. This warranty stands in lieu of all other warranties, expressed or implied. While this report can be used as a guide, it must be understood that it is neither a rejection nor an endorsement of the property, or of the means or methods used in the treatment, storage or disposal of potentially hazardous materials. Changing circumstances in the environment and in the use of the property can alter the conclusions and information contained in the report. 96 ___________________________________________________________________ Ellis
Table of Contents
Introduction
Site Description
Background
Applicable Regulations – Asbestos
Applicable Regulations – Lead
Methodology
Inaccessible Areas
Results
Summary and Recommendations
Statement of Independence
Signatory
Table 1 – Asbestos Summary
Table 2 – Lead Summary
Appendix A Photographs
Appendix B Material and Sample Locations
Appendix C Laboratory Results
Appendix D Ellis / Lab Certifications
Appendix E Regulatory Summaries
CDPH Form 8552
97 Ellis Environmental Management, Inc.
430 Silver Spur Road, Suite 201
Rancho Palos Verdes, CA 90275
Tel: (310) 544 1837
Fax: (310) 544 2167
www.ellisenvironmental.com
Environmental Testing ▫ Contract Administration ▫ Site Assessments and Closure Project No. 22-452
November 10, 2022
Elaine Jeng, City Manager
Rolling Hills
2 Portuguese Bend Road
Rolling Hills, CA 90274
Subject: BULK SAMPLING FOR ASBESTOS AND LEAD
ROLLING HILLS CITY HALL – 2 PORTUGUESE BEND RD,
ROLLING HILS, CA 90274
INTRODUCTION
On October 28, 2022, Ellis performed the following services at the subject site:
• an inspection for possible asbestos- and lead-containing building materials To the best of our knowledge, this survey and report have been prepared to include the following asbestos- and lead-specific components:
a. survey sampling protocol to include collection, sampling and analysis methods b. initial characterization of asbestos waste stream(s) c. certification of the inspector as a CSST
d. certification of the inspector as a CDPH lead sampling technician e. certification of the report preparer as a CAC
f. certification of the report preparer as a CDPH lead inspector/assessor g. state laboratory certification
SITE DESCRIPTION
At the time of sampling, the subject site was an occupied office / city hall facility, construction date currently unknown. The structure’s framing and exterior walls are comprised of a combination of wood and stucco. The interior walls and ceilings of the structure are comprised of plaster, stucco, and wallboard. The roofing system is comprised of an asphalt style roofing paper with overlayed concrete shingles and surface mastics and sealants covering any roofing field penetrations or flashings.
98 Ellis page 2
BACKGROUND – ASBESTOS AND LEAD
Asbestos-containing materials and lead-based paints have been widely used in the construction of public and commercial buildings since the 1930's. Insulation and fireproofing in more than 750,000 buildings in this country contain some quantity of asbestos. Lead paint was widely applied up until circa 1978, when concentrations of lead in paint began to be reduced.
In their normal state, most types of asbestos-containing building materials are unlikely to release airborne fibers. When broken up or disturbed improperly, however, asbestos fibers may become airborne. “Friable” materials – that is, materials that can be crushed using normal hand pressure – are more likely to release airborne fibers when disturbed improperly. Inhalation exposure to high levels of asbestos over long periods and/or ingestion of lead-based paint are associated with an increased incidence of cancer, respiratory, liver and other diseases.
Asbestos is primarily an inhalation hazard. Lead-based paint, when damaged (peeling or flaking), is primarily an ingestion hazard. Any activity that could disturb asbestos materials or lead-based paint should be undertaken with care and in accordance with applicable law.
APPLICABLE REGULATIONS – ASBESTOS
Current state and federal regulations pertaining to asbestos are summarized below. The summary is not all-inclusive and does not address specific removal or disposal requirements for individual materials.
NESHAPS
The National Emission Standard for Hazardous Air Pollutants (NESHAP), regulation 40 CFR Part 61, states that no visible emissions are allowed during building demolition or renovation activities which involve regulated asbestos-containing materials (RACMs). All buildings, regardless of construction date, must be surveyed for ACMs prior to demolition or renovation. The US EPA and/or the local air quality management district which implements US EPA actions must be notified prior to any building demolition, even if no ACMs are present. An ACM is defined as any material with an asbestos content of greater than one percent and which (a) is friable, or (b) Category I nonfriable ACM that has or will become friable, or (c) Category II friable ACM that may become or will become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation.
According to NESHAP, ACM is material containing more than one percent asbestos as determined using the methods specified in Appendix A, Subpart E, 40 CFR Part 763, Section 1, PLM. The NESHAP classifies ACM as friable or non-friable. Friable ACM is ACM that contains more than one percent asbestos and when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
Non-friable ACM also contains more than one percent asbestos and is further classified as either Category I ACM or Category II ACM. The materials are distinguished by their potential to release fibers when damaged. Category I ACMs are much more likely to release fibers when damaged.
In accordance with the US EPA's NESHAP regulation, facilities planned for renovation or demolition must be surveyed for the total amount of asbestos materials, which must be categorized 99 Ellis page 3
as friable, Category 1 non-friable, and Category 2 non-friable ACMs.
Southern California Air Quality Management District (SCAQMD) The SCAQMD is a government agency that regulates sources of air pollution within the area of the Los Angeles and surrounding counties. The District’s regulating and enforcement authority comes from federal law. In response to the NESHAP requirements, the SCAQMD implemented Rule 1403 to specify work practice requirements to limit asbestos emissions from building demolition and renovation activities, including the removal and associated disturbance of asbestos-containing materials (ACM). The requirements for demolition and renovation activities include asbestos surveying, notification, ACM removal procedures and time schedules, ACM handling and clean-up procedures, and storage, disposal, and landfilling requirements for asbestos-containing waste materials (ACWM). All operators are required to maintain records, including waste shipment records, and are required to use appropriate warning labels, signs, and markings.
AHERA
The Asbestos Hazard Emergency Response Act (AHERA) requires performance of asbestossurveys and the development of Asbestos Management Plans for all of the nation's primary and secondary schools. The general procedures mandated under AHERA are considered the industry standard and are applied to all surveys performed.
Cal-OSHA
Per Cal-OSHA standards, 1926.1101, Asbestos-Containing Construction Materials (ACCMs) are defined as any material with an asbestos content greater than one-tenth of one percent (>0.1%). CalOSHA sets forth work requirements for disturbance of ACCMs including removal operations for all types of ACCMs. The requirements have been classified as Class I, Class II, Class III, or Class IV Asbestos related work. The classes are distinguished by their potential to release fibers. Cal-OSHA prescribesspecific engineering controls and work practices for each Class of Asbestos related Work.
1. Class I – This Class refers to removal of ACMs identified as Thermal System Insulation (TSI) or surfacing (sprayed-on or troweled-on) materials. These materials are generally considered friable.
2. Class II – This Class refers to removal of ACMs identified that are not TSI or surfacing materials. These materials are generally considered non-friable.
3. Class III – This Class refers to repair and maintenance operations of all identified ACMs.
4. Class IV – This Class refers to incidental contact with identified ACMs such as custodial staff.
California Health and Safety Code
The California Health and Safety Code 25915 (former Connelly Bill) requires all building owners in the State of California to provide written notification to employees, tenants, and contractors of the presence and location of ACCMs within their buildings. Some exclusion to the notification rule for restricted access areas is allowed. All documentation related to asbestos surveys (and air monitoring) must be made available to employees, tenants, or contractors for review. ACCMs are defined as any materials with an asbestos content greater than one-tenth of one percent (>0.1%). The California Health and Safety Code also require that a seller with any knowledge of ACMs on a property disclose such information or knowledge to other parties involved in a real estate transaction. 100
Ellis page 4
Building Demolition / Renovation
In accordance with the US EPA's NESHAPs regulation and the SCAQMD, all structures planned for renovation or demolition must be surveyed for ACMs prior to the planned renovation or demolition.
Subsequent removal of identified ACMs is also required. Removal involves, to the greatest extent practical, the complete removal, disposal, and replacement, if necessary, of the ACMs. Removal usually also requires encapsulation of the remaining structure to lock down residual fibers which may exist. Removal of ACMs is required prior to renovation and/or demolition activities. The US EPA and SCAQMD require removal of all RACMs prior to demolition or renovation. RACMs include friable and non-friable (Category I and II) which have or will become friable by demolition or renovation activities.
APPLICABLE REGULATIONS – LEAD
California Title 8. Industrial Relations, Division 1, Department of Industrial Relations, Chapter 4, Division of Industrial Safety, Subchapter 4, Construction Safety Orders, Article 4, Dusts, Fumes, Mists, Vapors, and Gases, §1532.1, Lead.
This section applies to all construction work where an employee may be occupationally exposed to lead. All construction work excluded from coverage in the general industry standard for lead by section 5198(a)(2) is covered by this standard. Construction work is defined as work for construction, alteration and/or repair, including painting and decorating. It includes but is not limited to the following [applicable portions in bold text]:
(1) Demolition or salvage of structures where lead or materials containing lead are present; (2) Removal or encapsulation of materials containing lead; (3) New construction, alteration, repair, or renovation of structures, substrates, or portions thereof, that contain lead, or materials containing lead;
(4) Installation of products containing lead;
(5) Lead contamination/emergency cleanup;
(6) Transportation, disposal, storage, or containment of lead or materials containing lead on the site or location at which construction activities are performed, and (7) Maintenance operations associated with the construction activities described in this subsection.
California Health & Safety Code 17961 et al.
Deems a building to be in violation of state law if it contains lead hazards and requires local enforcement agencies to enforce provisions related to lead hazards. Makes it a crime for a person to engage in specified acts related to lead hazard evaluation, abatement, and lead-related construction courses unless certified or accredited by the Department. Permits local enforcement agencies to order the abatement of lead hazards or issue a cease and desist order in response to lead hazards.
California Labor Code 6716 to 6717 Lead-Related Activities in Construction Work Provides for the establishment of standards that protect the health and safety of employees who engage in lead-related construction work, including construction, demolition, renovation and repair.
California Code of Regulations, Title 17, Section 35001 Includes requirements for lead hazard evaluation and abatement activities, accreditation of training providers, and certification of individuals engaged in lead-based paint activities. 101
Ellis page 5
METHODOLOGY
Bulk Sampling of Suspect Asbestos-Containing Materials
A sampling plan was first prepared, listing each material to be sampled, sample location, and material condition. Accessible building materials were visually inspected using the methods presented in the Federal Asbestos Hazard Emergency Response Act (AHERA) regulations (40 CFR, Part 763) as a guideline. AHERA was originally only applicable to schools, however state and federal Occupational Safety and Health Administration (OSHA) and Asbestos School Hazard Abatement and Reauthorization Act (ASHARA) have adopted the AHERA sampling methodology for all buildings subject to demolition or renovation.
Bulk samples of all suspect ACM homogeneous materials were collected. A homogeneous material is defined as a surfacing material, thermal system insulation, or miscellaneous material that is uniform in color, texture and age of construction. Examples of homogeneous materials include:
• Pipe-insulation produced by the same manufacturer and installed during the same time period; • Resilient flooring of identical color and pattern;
• Troweled on surfacing materials located in contiguous areas.
The structure was visually inspected for the presence of suspect materials. As materials were identified, bulk samples were obtained with the aid of a coring device or other hand tool and placed into individual sampling bags. Each sample was given a discrete identification number and recorded on field notes as well as chain-of-custody forms. Bulk samples were transported to and analyzed at an AIHA accredited laboratory. Analysis method used: 40 CFR Part 763, Subpart F, Appendix A. (AHERA Final Rule). Results expressed in percent of measured area.
Cal-OSHA defines asbestos containing construction materials (ACCM) as those materials having asbestos content of greater than one tenth of one percent (>0.1%). When None Detected (ND) appears in this report, it should be interpreted as meaning no asbestos was observed in the sampled material above the reliable limit of detection for the PLM method employed.
Note: under EPA assessment criteria, if a single sample of a homogeneous material tests positive for asbestos, all similar materials within that area are considered to be asbestos containing.
Bulk Sampling of Suspect Lead-containing Materials
Paint chip and/or other suspected lead containing materials were collected using a hand scraper, small chisel or other tool. Each sample was placed into an individual plastic sample container with a unique identification number. Paint samples were hand delivered to an AIHA accredited laboratory for initial analysis using EPA Method 3050B/6010B, and by EPA Method Total Threshold Limit Concentration (TTLC). (When “<” appears in the lead analysis report, it should be interpreted as meaning below the analytical detection limit.) All samples were collected by Shawn Sokolsky, an EPA-accredited building inspector and lead inspectors/risk assessor employed by Ellis.
INACCESSIBLE AREAS
Not all walls, ceilings or floors were demolished to gain complete visual access. The roof of the structure was not sampled as part of this survey. There is a chance that additional suspect materials (pipe insulation in walls and above sub-ceilings, asbestos-cement vent pipes, underground drains, 102
Ellis page 6
primer on steel structural members, etc.) may be exposed during demolition activities.
Initiate demolition carefully. Any materials exposed but not identified in existing reports should be sampled and analyzed prior to disturbance.
RESULTS
See Tables 1-2. Also refer to the attached laboratory results, summarized below.
Asbestos
Asbestos was detected in the following sampled material:
1. exterior stucco – (<0.1% chrysotile, good condition / “non-friable” – appx. 500 ft2 in qty.*)
2. acoustic ceiling (soft) – (6-7% chrysotile, good condition / “friable” – appx. 2,000 ft2
in qty.*)
3. ceiling plaster – (2% chrysotile, good condition / “non-friable” – appx. 2,000 ft2 in qty.*)
4. wall plaster – (<0.1% chrysotile, good condition / “non-friable” – appx. 2,000 ft2 in
qty.*)
5. resilient sheet flooring / linoleum (upper) and associated mastic – (5-8% chrysotile, good condition / “friable” – appx. 300 ft2 in qty.*)
6. resilient sheet flooring / linoleum (bottom) and associated mastic – (20% chrysotile, good condition / “friable” – appx. 100 ft2 in qty.*)
7. 9” x 9” vinyl floor tile . associated mastic – (6-8% chrysotile, good condition / “non-friable” – appx. 150 ft2
in qty.*)
8. window putty – (2% chrysotile, good condition / “non-friable” – appx. 10 ft2 in
qty.*)
* Not for bidding purposes. Conditions noted are representative of observations on the date of sampling (only).
Field verify all listed quantities and conditions.
A licensed abatement contractor is required for the disturbance or removal of the asbestoscontaining materials with greater than 0.1% asbestos content noted above. Reference Table 1 for a complete list of asbestos-related samples.
The removal of any material containing asbestos in an amount greater than one percent (AsbestosContaining Material or ACM) is regulated under EPA-SCAQMD Rule 1403, 29 CFR 1926.1101 (federal OSHA) and other state and local guidelines. Removal of any material containing asbestos in an amount greater than 0.1 percent is also regulated, under Cal-OSHA Title 8 Section 1529.
Asbestos-containing waste material (ACWM) generated during the removal of friable and nonfriable ACM must be disposed of as hazardous asbestos waste and non-hazardous asbestos waste, respectively. For asbestos-containing materials with asbestos concentrations of less than 1% but greater than 0.1%, so called Asbestos-Containing Construction Materials or ACCM, waste generated during abatement activities may be disposed of as standard construction waste but must still be removed by a DOSH registered abatement contractor. For asbestos-containing materials with asbestos concentrations less than 0.1%, removal or disturbance by a DOSH registered abatement contractor is not required; however, certain work practices outlined in Cal/OSHA Title 8 § 1529 may still apply. Prior to renovation or demolition, retain a licensed abatement contractor to remove 103
Ellis page 7
asbestos materials identified.
Lead-Containing Materials – Paint
The following sampled paints are “lead-based” (>0.06 % lead by wt.):
1. white front door paint – (0.074% lead by wt.)
2. white wall trim paint – (0.33% lead by wt.)
3. eggshell wall paint – (0.099% lead by wt.)
4. grey storage wall paint – (0.18% lead by wt.)
A licensed abatement contractor is required for the removal of disturbance of the lead-based paint listed above. Drum and profile all uniquely generated waste stream prior to transportation or disposal.
The following sampled paints are “lead-containing” (<0.06 % lead by wt.):
1. white exterior paint – (0.013% lead by wt.)
Avoid torching, welding, or mechanical abrading on lead-containing paints without prior exposure monitoring as is stipulated in Cal/OSHA Title 8 § 1532.1. No other special, leadrelated precautions required. Reference the attached lead “Trigger Tasks” document for additional information on “lead-based” (>.06%) and “lead-containing” (<.06%) paints and work practices.
Lead-Containing Materials – Ceramic Tile
The following sampled ceramic tile is “lead-containing” (>50 mg/Kg):
1. ceramic restroom wall tile – (76 mg/Kg)
A licensed abatement contractor is required for the removal of disturbance of the lead-based paint listed above. Drum and profile all uniquely generated waste stream prior to transportation or disposal. Reference Table 2 for a complete list of lead-related samples.
SUMMARY AND RECOMMENDATIONS
Asbestos
Retain a licensed abatement contractor for the removal or disturbance of the asbestos-containing materials noted to be present in this report.
Subsurface materials, such as asbestos-cement (AC, or “Transite”) may also be present. A review of existing utility plans may reveal their presence, location and quantity. AC pipe, when exposed during grading activities, must be removed under an SCAQMD-approved work plan (“Procedure 5”).
Lead
Retain a licensed abatement contractor for the removal or disturbance of the lead-based paints and lead-containing ceramic tile noted to be present in this report. Lead-based paint may be exposed on structural steel beams beneath fire proofing, and in other similar locations. If exposed but not identified in existing reports, any such materials should be sampled prior to disturbance. 104
Ellis page 8
Health and Safety Plan (HaSP)
A health and safety plan, or HaSP, is a plan for a workplace that is designed in accordance with the legislative requirements covering the roles and responsibilities of the staff, an emergency action plan etc. A health and safety plan is designed to serve and protect the individuals affected by the organization in all matters of health, wellbeing and safety.
The HaSP should be provided by the general or abatement contractor. A “site specific” health and safety plan mainly describes what kind of hazards are involved in the project, how they can be overcome and what sort of equipment will be used to overcome the problem. Health and safety plans will differ from job to job, but the underlying theme of every plan is that it should not only take care of the health and safety of the employees, but also ensure safety for visitors of the premises and the passersby1.
STATEMENT OF INDEPENDENCE
Ellis is a privately held company and is not affiliated with any financial institution or other corporate entity. Ellis is retained as an independent contractor to provide objective, impartial investigation or analytical services regarding environmentally regulated hazardous or toxic materials. This report is not an endorsement or rejection of any specific methods used in handling or transport of potentially hazardous chemicals. Nor is intended as a complete hazardous materials survey of the entire building or facility. Ellis provides independent testing for asbestos, lead, indoor air contaminants and other potentially hazardous materials. The company and its employees are certified and licensed to practice in the State of California. Retained laboratories are accredited by the EPA, AREAL, NIOSH, AIHA, and CARB.
SIGNATORY
Respectfully,
ELLIS ENVIRONMENTAL MANAGEMENT, INC.
Prepared by:
Ryan C. Davidson
Senior Project Manager
CAC #15-5395
CDPH #0368
proj # 22-452
Distribution: Elaine Jeng
1 SOURCE: www.safeopedia.com
105
REF. MATERIAL
MATERIAL
LOCATION FRIABLE DAMAGE % ASB QTY* UNIT
A1, A2,
A3 exterior stucco see Figures 1-2 no no <0.1% 500 ft²
A4, A5,
A6 acoustic ceiling (soft) see Figures 1-2 yes no 6-7% 2,000 ft² A7, A8,
A9 ceiling plaster see Figures 1-2 no no 2% 2,000 ft²
A13, A14,
A15 wall plaster see Figures 1-2 no no <0.1% 2,000 ft²
A22, A23,
A24
resilient sheet flooring /
linoleum (upper) and
associated mastic see Figures 1-2 yes no 5-8% 300 ft²
A25, A26,
A27
resilient sheet flooring /
linoleum (bottom) and
associated mastic see Figures 1-2 yes no 20% 100 ft²
A28, A29,
A30
9" x 9" vinyl floor tile /
associated mastic see Figures 1-2 no no 6-8% 150 ft²
A31, A32,
A33 window putty see Figures 1-2 no no 2% 10 ft²
A16, A17,
A18
white cove base /
associated mastic see Figures 1-2 - -
none
detected - -
A16, A17,
A18
green cove base /
associated mastic see Figures 1-2 - -
none
detected - -
A34, A35,
A36
red cove base /
associated mastic see Figures 1-2 - -
none
detected - -
A37, A38,
A39 carpet glue see Figures 1-2 - -
none
detected - -
A40, A41,
A42 acoustic ceiling (hard) see Figures 1-2 - -
none
detected - -
Not a complete survey; only client-specified materials were sampled.
IDENTIFIED ASBESTOS MATERIALS
NON-ASBESTOS MATERIALS
*Not for bidding purposes. Field verify all quantities and conditions.
Ellis
Table 1
Asbestos Results Summary
Rolling Hills City Hall
SHEET 1 OF 1
Proj. # 22-452
Sample Date: 10/28/22
106
REF. MATERIAL
LEAD
RESULTS
(% by wt.)
LEAD-BASED?
(>0.06% by wt.)
LEADCONTAINING?
(>0.01 to <0.06%
by wt.)
L1 white front door paint 0.074% YES -
L2 white wall trim paint 0.33% YES -
L5 eggshell wall paint 0.099% YES -
L6 grey storage wall paint 0.18% YES -
L8 white exterior paint 0.013% no YES
L4 white concrete floor paint <0.0080% no no
L7 white gutter paint <0.0080% no no
REF. MATERIAL
LEAD
RESULTS
(mg/Kg)
LEADCONTAINING
(>50 mg/Kg)
NON LEADCONTAINING?
(<50 mg/Kg)
L3 ceramic restroom wall tile 76 mg/Kg YES -
Not a complete survey; only client-specified materials and locations were sampled. See report text.
Ellis
Table 2
Lead Results Summary
Rolling Hills City Hall
SHEET 1 OF 1
Proj. # 22-452
Sample Date: 10/28/22
107
Ellis
APPENDIX A
PHOTOGRAPHS
108
Ellis
(above) Asbestos-containing acoustic ceiling and ceiling plaster.
(above) Asbestos-containing 9” floor tile/mastic.
109
Ellis
(above) Asbestos-containing linoleum (multi-layered).
(above) Asbestos-containing window putty.
110
Ellis
(above) Trace – asbestos containing wall plaster.
(above) Trace-asbestos containing exterior stucco overhang. 111
Ellis
(above) Lead-based white front door paint and lead-containing exterior white paint. (above) Lead-based interior white trim paint.
112
Ellis
(above) Lead-based gray storage room wall paint.
(above) Lead-based eggshell wall paint.
113
Ellis
(above) Lead-containing restroom ceramic wall tile.
114
Ellis
APPENDIX B
MATERIAL AND SAMPLE LOCATIONS
115
116
117
Ellis
APPENDIX C
LABORATORY RESULTS
118
LA Testing
520 Mission Street South Pasadena, CA 91030
Tel/Fax: (323) 254-9960 / (323) 254-9982
http://www.LATesting.com / [email protected]
LA Testing Order: 322221852
Customer ID: 32EEMI45
Customer PO:
Project ID:
Attention: Duane Behrens Phone: (310) 686-7470
Ellis Environmental Management, Inc. Fax:
430 Silver Spur Road Received Date: 10/28/2022 1:10 PM
Suite 201 Analysis Date: 11/02/2022 - 11/03/2022
Rancho Palos Verdes, CA 90275 Collected Date: 10/28/2022 Project: 22-452/ 2 Portuguese Bend Rd. Rolling Hills CA, 90274 Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
A1
322221852-0001
Gray/White 100% Non-fibrous (Other) <1% Chrysotile
Non-Fibrous
Homogeneous
Ext. stucco
A2
322221852-0002
Gray/White 100% Non-fibrous (Other) <1% Chrysotile
Non-Fibrous
Homogeneous
Ext. stucco
A3-Finish Coat
322221852-0003
White 100% Non-fibrous (Other) <1% Chrysotile
Non-Fibrous
Homogeneous
Ext. stucco
A3-Base Coat
322221852-0003A
Gray 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Ext. stucco
A4
322221852-0004
Mica 7% Chrysotile
Non-fibrous (Other)
10%
83%
Gray/White/Gold
Non-Fibrous
Homogeneous
Acoustic ceiling (soft)
A5
322221852-0005
Mica 7% Chrysotile
Non-fibrous (Other)
10%
83%
Tan/White/Gold
Non-Fibrous
Homogeneous
Acoustic ceiling (soft)
A6
322221852-0006
Mica 6% Chrysotile
Non-fibrous (Other)
5%
89%
Gray/White/Gold
Non-Fibrous
Homogeneous
Acoustic ceiling (soft)
A7
322221852-0007
White/Beige 98% Non-fibrous (Other) 2% Chrysotile
Non-Fibrous
Homogeneous
Ceiling plaster
A8
322221852-0008
White/Beige 98% Non-fibrous (Other) 2% Chrysotile
Non-Fibrous
Homogeneous
Ceiling plaster
A9
322221852-0009
White/Beige 98% Non-fibrous (Other) 2% Chrysotile
Non-Fibrous
Homogeneous
Ceiling plaster
A10-Wallboard
322221852-0010
Brown/White 20% Cellulose 80% Non-fibrous (Other) None Detected Fibrous
Heterogeneous
Ceiling wb/jc
A10-Joint Compound
322221852-0010A
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Ceiling wb/jc
A11-Wallboard
322221852-0011
Brown/White 20% Cellulose 80% Non-fibrous (Other) None Detected Fibrous
Heterogeneous
Ceiling wb/jc
A11-Joint Compound
322221852-0011A
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Ceiling wb/jc
A12-Wallboard
322221852-0012
Brown/White 20% Cellulose 80% Non-fibrous (Other) None Detected Fibrous
Heterogeneous
Ceiling wb/jc
A12-Joint Compound
322221852-0012A
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Ceiling wb/jc
Initial report from: 11/03/2022 11:05:25
ASB_PLM_0008_0001 - 1.78 Printed: 11/3/2022 11:05 AM Page 1 of 5 119 LA Testing
520 Mission Street South Pasadena, CA 91030
Tel/Fax: (323) 254-9960 / (323) 254-9982
http://www.LATesting.com / [email protected]
LA Testing Order: 322221852
Customer ID: 32EEMI45
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
A13
322221852-0013
Gray/White 100% Non-fibrous (Other) <1% Chrysotile
Non-Fibrous
Homogeneous
Wall plaster
A14
322221852-0014
Gray/White 100% Non-fibrous (Other) <1% Chrysotile
Non-Fibrous
Homogeneous
Wall plaster
A15
322221852-0015
Gray/White 100% Non-fibrous (Other) <1% Chrysotile
Non-Fibrous
Homogeneous
Wall plaster
A16-Cove Base
322221852-0016
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
White cb/mastic
A16-Mastic
322221852-0016A
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
White cb/mastic
A16-Joint Compound
322221852-0016B
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
White cb/mastic
A17-Cove Base
322221852-0017
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
White cb/mastic
A17-Mastic
322221852-0017A
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
White cb/mastic
A17-Joint Compound
322221852-0017B
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
White cb/mastic
A18-Cove Base
322221852-0018
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
White cb/mastic
A18-Mastic
322221852-0018A
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
White cb/mastic
A18-Joint Compound
322221852-0018B
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
White cb/mastic
A19-Cove Base
322221852-0019
Gray 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Green cb/mastic
A19-Mastic
322221852-0019A
Brown 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Green cb/mastic
A19-Joint Compound
322221852-0019B
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Green cb/mastic
A20-Cove Base
322221852-0020
Gray 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Green cb/mastic
A20-Mastic
322221852-0020A
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Green cb/mastic
A20-Joint Compound
322221852-0020B
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Green cb/mastic
A21-Cove Base
322221852-0021
Gray 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Green cb/mastic
Initial report from: 11/03/2022 11:05:25
ASB_PLM_0008_0001 - 1.78 Printed: 11/3/2022 11:05 AM Page 2 of 5 120 LA Testing
520 Mission Street South Pasadena, CA 91030
Tel/Fax: (323) 254-9960 / (323) 254-9982
http://www.LATesting.com / [email protected]
LA Testing Order: 322221852
Customer ID: 32EEMI45
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
A21-Mastic
322221852-0021A
Brown 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Green cb/mastic
A22-Caulking Like
322221852-0022
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Linoleum
A22-Linoleum
322221852-0022A
Cellulose 77% Non-fibrous (Other) None Detected
Glass
20%
3%
White/Pink/Beige
Fibrous
Heterogeneous
Linoleum
A22-Mastic 1
322221852-0022B
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Linoleum
A22-Mastic 2
322221852-0022C
Black 95% Non-fibrous (Other) 5% Chrysotile
Non-Fibrous
Homogeneous
Linoleum
A23-Caulking Like
322221852-0023
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Linoleum
A23-Linoleum
322221852-0023A
Cellulose 78% Non-fibrous (Other) None Detected
Glass
20%
2%
White/Pink/Beige
Fibrous
Heterogeneous
Linoleum
A23-Mastic 1
322221852-0023B
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Linoleum
A23-Mastic 2
322221852-0023C
Black 92% Non-fibrous (Other) 8% Chrysotile
Non-Fibrous
Homogeneous
Linoleum
A24-Caulking Like
322221852-0024
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Linoleum
A24-Linoleum
322221852-0024A
Cellulose 78% Non-fibrous (Other) None Detected
Glass
20%
2%
White/Pink/Beige
Fibrous
Heterogeneous
Linoleum
A24-Mastic 1
322221852-0024B
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Linoleum
A24-Mastic 2
322221852-0024C
Black 90% Non-fibrous (Other) 10% Chrysotile
Non-Fibrous
Homogeneous
Linoleum
A25-Mastic 1
322221852-0025
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Bottom linoleum
A25-Linoleum
322221852-0025A
Brown/Tan/Beige 80% Non-fibrous (Other) 20% Chrysotile
Fibrous
Homogeneous
Bottom linoleum
A25-Mastic 2 /Mastic 3
322221852-0025B
Black/Yellow 100% Non-fibrous (Other) None Detected
Non-Fibrous
Heterogeneous
Bottom linoleum
Unable to separate
A26-Mastic 1
322221852-0026
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Bottom linoleum
A26-Linoleum
322221852-0026A
Brown/Tan/Beige 80% Non-fibrous (Other) 20% Chrysotile
Fibrous
Heterogeneous
Bottom linoleum
Initial report from: 11/03/2022 11:05:25
ASB_PLM_0008_0001 - 1.78 Printed: 11/3/2022 11:05 AM Page 3 of 5 121 LA Testing
520 Mission Street South Pasadena, CA 91030
Tel/Fax: (323) 254-9960 / (323) 254-9982
http://www.LATesting.com / [email protected]
LA Testing Order: 322221852
Customer ID: 32EEMI45
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
A26-Mastic 2/Mastic 3
322221852-0026B
Black/Yellow 100% Non-fibrous (Other) None Detected
Non-Fibrous
Heterogeneous
Bottom linoleum
Unable to separate
A27-Mastic 1
322221852-0027
Beige 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Bottom linoleum
A27-Linoleum
322221852-0027A
Brown/Tan/Beige 80% Non-fibrous (Other) 20% Chrysotile
Fibrous
Heterogeneous
Bottom linoleum
A27-Mastic 2/Mastic 3
322221852-0027B
Black/Yellow 100% Non-fibrous (Other) None Detected
Non-Fibrous
Heterogeneous
Bottom linoleum
Unable to separate
A28-Floor Tile
322221852-0028
Gray/White 94% Non-fibrous (Other) 6% Chrysotile
Non-Fibrous
Homogeneous
9" ft/mastic
A28-Mastic
322221852-0028A
Black 92% Non-fibrous (Other) 8% Chrysotile
Non-Fibrous
Homogeneous
9" ft/mastic
A29-Floor Tile
322221852-0029
Gray/White 93% Non-fibrous (Other) 7% Chrysotile
Non-Fibrous
Homogeneous
9" ft/mastic
A29-Mastic
322221852-0029A
Black 92% Non-fibrous (Other) 8% Chrysotile
Non-Fibrous
Homogeneous
9" ft/mastic
A30-Floor Tile
322221852-0030
Gray/White 93% Non-fibrous (Other) 7% Chrysotile
Non-Fibrous
Homogeneous
9" ft/mastic
A30-Mastic
322221852-0030A
Black 90% Non-fibrous (Other) 10% Chrysotile
Non-Fibrous
Homogeneous
9" ft/mastic
A31
322221852-0031
Gray/Beige 98% Non-fibrous (Other) 2% Chrysotile
Non-Fibrous
Homogeneous
Window putty
A32
322221852-0032
Gray/Beige 98% Non-fibrous (Other) 2% Chrysotile
Non-Fibrous
Homogeneous
Window putty
A33
322221852-0033
Gray/Beige 98% Non-fibrous (Other) 2% Chrysotile
Non-Fibrous
Homogeneous
Window putty
A34-Cove Base
322221852-0034
Brown 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Red cb/mastic
A34-Mastic 1
322221852-0034A
Yellow 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Red cb/mastic
A34-Mastic 2
322221852-0034B
Brown 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Red cb/mastic
A35-Cove Base
322221852-0035
Brown 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Red cb/mastic
A35-Mastic 1
322221852-0035A
Yellow 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Red cb/mastic
Initial report from: 11/03/2022 11:05:25
ASB_PLM_0008_0001 - 1.78 Printed: 11/3/2022 11:05 AM Page 4 of 5 122 LA Testing
520 Mission Street South Pasadena, CA 91030
Tel/Fax: (323) 254-9960 / (323) 254-9982
http://www.LATesting.com / [email protected]
LA Testing Order: 322221852
Customer ID: 32EEMI45
Customer PO:
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
A35-Mastic 2
322221852-0035B
Brown 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Red cb/mastic
A36-Cove Base
322221852-0036
Brown 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Red cb/mastic
A36-Mastic 1
322221852-0036A
Yellow 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Red cb/mastic
A36-Mastic 2
322221852-0036B
Brown 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Red cb/mastic
A37
322221852-0037
Brown/Yellow 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Carpet glue
A38
322221852-0038
Brown/Yellow 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Carpet glue
A39
322221852-0039
Brown/Yellow 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Carpet glue
A40
322221852-0040
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Acoustic ceiling (hard)
A41
322221852-0041
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Acoustic ceiling (hard)
A42
322221852-0042
White 100% Non-fibrous (Other) None Detected
Non-Fibrous
Homogeneous
Acoustic ceiling (hard)
Analyst(s)
David Flores (54)
Tania Lopez (27)
Jerry Drapala Ph.D, Laboratory Manager
or Other Approved Signatory
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore LA Testing recommends gravimetric reduction prior to analysis.
Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by LA Testing South Pasadena, CA NVLAP Lab Code 200232-0, CA ELAP 2283 Initial report from: 11/03/2022 11:05:25
ASB_PLM_0008_0001 - 1.78 Printed: 11/3/2022 11:05 AM Page 5 of 5 123 OrderID: 322221852
124
OrderID: 322221852
125
OrderID: 322221852
126
OrderID: 322221852
127
LA Testing
520 Mission Street South Pasadena, CA 91030
Phone/Fax: (323) 254-9960 / (323) 254-9982
http://www.LATesting.com / [email protected]
LA Testing Order: 322222344
Customer ID: 32EEMI45
Customer PO:
Project ID:
Attention: Ellis Environmental Management, Inc. Phone: (310) 544-1837 Ellis Environmental Management, Inc. Fax:
430 Silver Spur Road Received: 11/08/2022 1:45 PM
Suite 201 Analysis Date: 11/09/2022
Rancho Palos Verdes, CA 90275 Collected:
Project: REF PLM REPORT: 322221852 | 22-452/ 2 Portuguese Bend Rd. Rolling Hills CA, 90274 Test Report: Asbestos Analysis of Bulk Material via EPA 600/R-93/116. Quantitation using the 1,000 Point Count Procedure
Sample Description Appearance % Fibrous % Non-Fibrous % Type Non-Asbestos Asbestos
Gray/White
Non-Fibrous
Homogeneous
A1 Ext. Stucco
322222344-0001
100.0% Non-fibrous (Other) <0.1%Chrysotile
Gray/White
Non-Fibrous
Homogeneous
A2 Ext. Stucco
322222344-0002
100.0% Non-fibrous (Other) <0.1%Chrysotile
White
Non-Fibrous
Homogeneous
A3-Finish Coat Ext. Stucco
322222344-0003
100.0% Non-fibrous (Other) <0.1%Chrysotile
Gray/White
Non-Fibrous
Homogeneous
A13 Wall Plaster
322222344-0004
100.0% Non-fibrous (Other) <0.1%Chrysotile
Gray/White
Non-Fibrous
Homogeneous
A14 Wall Plaster
322222344-0005
100.0% Non-fibrous (Other) <0.1%Chrysotile
Gray/White
Non-Fibrous
Homogeneous
A15 Wall Plaster
322222344-0006
100.0% Non-fibrous (Other) <0.1%Chrysotile
Analyst(s)
Rosa Mendoza (6) Jerry Drapala Ph.D, Laboratory Manager or other approved signatory
LA Testing maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by LA Testing. LA Testing bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received. Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non-friable organically bound materials present a problem matrix and therefore LA Testing recommends gravimetric reduction prior to analysis. Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample.
Estimation of uncertainty is available on request.
Samples analyzed by LA Testing South Pasadena, CA NVLAP Lab Code 200232-0, CA ELAP 2283 Initial report from: 11/09/2022 08:33:01
ASB_PLMPC_0006_0003 Printed 11/9/2022 8:33:31AM Page 1 of 1 128 OrderID: 322222344 Page 1 Of 3
129
OrderID: 322222344 Page 2 Of 3
130
OrderID: 322222344 Page 3 Of 3
131
Client Sample Description Lab ID Analyzed Weight Concentration Lead
Collected
EMSL Analytical, Inc
464 McCormick Street, San Leandro, CA 94577
Phone/Fax: (510) 895-3675 / (510) 895-3680
http://www.EMSL.com [email protected]
Attn: Ellis Environmental Management, Inc.
Ellis Environmental Management, Inc.
430 Silver Spur Road
Suite 201
Rancho Palos Verdes, CA 90275
Received: 10/31/2022 09:00 AM
22-452
Fax:
Phone: (310) 544-1837
Project:
Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)* 092224719
CustomerID: 32EEMI45
CustomerPO:
ProjectID:
EMSL Order:
0.2551
Site: WHITE FRONT DOOR PAINT
L1 092224719-0001 11/5/2022 g 0.074 % wt
0.2569
Site: WHITE WALL TRIM PAINT
L2 092224719-0002 11/5/2022 g 0.33 % wt
0.2547
Site: WHITE CONCRETE FLOOR PAINT
L4 092224719-0004 11/5/2022 g <0.0080 % wt
0.2575
Site: EGGSHELL WALL PAINT
L5 092224719-0005 11/5/2022 g 0.099 % wt
0.2546
Site: GRAY STORAGE WALL PAINT
L6 092224719-0006 11/5/2022 g 0.18 % wt
0.2517
Site: WHITE GUTTER PAINT
L7 092224719-0007 11/5/2022 g <0.0080 % wt
0.2542
Site: EXT WHITE PAINT
L8 092224719-0008 11/5/2022 g 0.013 % wt
Julian Neagu, Lead Laboratory Manager
or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 11/5/2022 2:02:52 PM EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.
* Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc San Leandro, CA AIHA-LAP, LLC-ELLAP Accredited #101748 Initial report from 11/05/2022 14:02:52
132
Client Sample Description Lab ID Analyzed Weight (g) Concentration Lead
Collected
EMSL Analytical, Inc
464 McCormick Street, San Leandro, CA 94577
Phone/Fax: (510) 895-3675 / (510) 895-3680
http://www.EMSL.com [email protected]
Attn: Ellis Environmental Management, Inc.
Ellis Environmental Management, Inc.
430 Silver Spur Road
Suite 201
Rancho Palos Verdes, CA 90275
Received: 10/31/2022 09:00 AM
22-452
Fax:
Phone: (310) 544-1837
Project:
Collected:
Test Report: Total Threshold Limit Concentration (7000B) 092224719
CustomerID: 32EEMI45
CustomerPO:
ProjectID:
EMSL Order:
0.5095
Site: CERAMIC RR WALL TILE
L3 092224719-0003 11/4/2022 g 76 mg/Kg
Julian Neagu, Lead Laboratory Manager
or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 11/5/2022 2:02:52 PM EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. Reporting limit is 40 mg/kg based on a 0.5 gram sample weight. "<" (less than) result signifies that the analyte was not detected at or above the reporting limit.
Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc San Leandro, CA Method SW 846 7000B replaces EPA 7420 for lead analysis and is an equivalent method. CA ELAP 1628, AIHA-LAP, LLC-ELLAP Accredited #101748
Initial report from 11/05/2022 14:02:52
133
OrderID: 092224719
134
OrderID: 092224719
135
OrderID: 092224719
136
OrderID: 092224719
137
Ellis
APPENDIX D
ELLIS / LABORATORY CERTIFICATIONS
138
139
140
141
142
Ellis
APPENDIX E
REGULATORY SUMMARIES / CDPH 8552 FORM
143
APPLICABLE REGULATIONS – LEAD
California Title 8. Industrial Relations, Division 1, Department of Industrial Relations, Chapter 4, Division of Industrial Safety, Subchapter 4, Construction Safety Orders, Article 4, Dusts, Fumes, Mists, Vapors, and Gases, §1532.1, Lead.
This section applies to all construction work where an employee may be occupationally exposed to lead. All construction work excluded from coverage in the general industry standard for lead by section 5198(a)(2) is covered by this standard. Construction work is defined as work for construction, alteration and/or repair, including painting and decorating. It includes but is not limited to the following:
(1) Demolition or salvage of structures where lead or materials containing lead are present; (2) Removal or encapsulation of materials containing lead; (3) New construction, alteration, repair, or renovation of structures, substrates, or portions thereof, that contain lead, or materials containing lead;
(4) Installation of products containing lead;
(5) Lead contamination/emergency cleanup;
(6) Transportation, disposal, storage, or containment of lead or materials containing lead on the site or location at which construction activities are performed, and (7) Maintenance operations associated with the construction activities described in this subsection.
California Health & Safety Code 17961 et al.
Deems a building to be in violation of state law if it contains lead hazards, and requires local enforcement agencies to enforce provisions related to lead hazards. Makes it a crime for a person to engage in specified acts related to lead hazard evaluation, abatement, and lead-related construction courses unless certified or accredited by the Department. Permits local enforcement agencies to order the abatement of lead hazards or issue a cease and desist order in response to lead hazards.
California Labor Code 6716 to 6717 Lead-Related Activities in Construction Work Provides for the establishment of standards that protect the health and safety of employees who engage in lead-related construction work, including construction, demolition, renovation and repair.
California Code of Regulations, Title 17, Section 35001 Includes requirements for lead hazard evaluation and abatement activities, accreditation of training providers, and certification of individuals engaged in lead-based paint activities. 144
LEAD - “TRIGGER TASKS”
(SOURCE: California Title 8 Section 1532.1.)
Following testing, Construction Managers and Superintendents may use the following to decide whether (and for how long) an abatement contractor should be retained during disturbance of painted surfaces.
Paint Categories
1. Lead-Based. >.06% Lead by Weight. Start-to-finish, retain an abatement contractor to perform trigger tasks listed below.
2. Lead-Containing. 0.009 – 0.06% lead by weight. Avoid torching or mechanical grinding; no other special precautions.
3. Non-Lead-Containing <.009% lead by weight. No special lead-related precautions required.
TRIGGER TASKS - Lead-Based Paints Only:
Lowest Exposure Trigger Tasks:
Unless proven otherwise (Negative Exposure Assessment, or "NEA"), assume exposures greater than 50 and up to 500 μg/m3 where lead-based coatings or paint are present:
• manual demolition of structures
• manual scraping
• manual sanding
• heat gun applications
• power tool cleaning with dust collection system
• spray painting with lead
• any other task where employees may be exposed over the PEL.
Medium Exposure Trigger Tasks:
Unless proven otherwise (NEA), assume exposures greater than 500 and up to 2,500 μg/m3 where leadbased coatings or paint are present:
• use of lead-containing mortar
• lead burning
• rivet busting
• power tool cleaning without dust collection systems
• cleanup of dry expendable abrasives
• abrasive blasting enclosure movement and removal
Highest Exposure Trigger Tasks:
Assume exposures greater than 2,500 μg/m3 unless proven otherwise where lead-based coatings or paint are present:
• abrasive blasting
• welding
• cutting
• torch burning
145
Ellis www.ellisenvironmental.com 310 544 1837
APPLICABLE REGULATIONS – ASBESTOS
Current state and federal regulations pertaining to asbestos are summarized below. The summary is not all-inclusive, and does not address specific removal or disposal requirements for individual materials.
NESHAPS
The National Emission Standard for Hazardous Air Pollutants (NESHAP), regulation 40 CFR Part 61, states that no visible emissions are allowed during building demolition or renovation activities which involve regulated asbestos-containing materials (RACMs). All buildings, regardless of construction date, must be surveyed for ACMs prior to demolition or renovation. The US EPA and/or the local air quality management district which implements US EPA actions must be notified prior to any building demolition, even if no ACMs are present. An ACM is defined as any material with an asbestos content of greater than one percent and which (a) is friable, or (b) Category I non-friable ACM that has or will become friable, or (c) Category II friable ACM that may become or will become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of demolition or renovation.
According to NESHAP, ACM is material containing more than one percent asbestos as determined using the methods specified in Appendix A, Subpart E, 40 CFR Part 763, Section 1, PLM. The NESHAP classifies ACM as friable or non-friable. Friable ACM is ACM that contains more than one percent asbestos and when dry, can be crumbled, pulverized, or reduced to powder by hand pressure.
Non-friable ACM also contains more than one percent asbestos and is further classified as either Category I ACM or Category II ACM. The materials are distinguished by their potential to release fibers when damaged. Category I ACMs are much more likely to release fibers when damaged.
In accordance with the US EPA's NESHAP regulation, facilities planned for renovation or demolition must be surveyed for the total amount of asbestos materials, which must be categorized as friable, Category 1 non-friable, and Category 2 non-friable ACMs.
Southern California Air Quality Management District (SCAQMD) The SCAQMD is a government agency that regulates sources of air pollution within the area of the Los Angeles and surrounding counties. The District’s regulating and enforcement authority comes from federal law. In response to the NESHAP requirements, the SCAQMD implemented Rule 1403 to specify work practice requirements to limit asbestos emissions from building demolition and renovation activities, including the removal and associated disturbance of asbestos-containing materials (ACM). The requirements for demolition and renovation activities include asbestos surveying, notification, ACM removal procedures and time schedules, ACM handling and clean-up procedures, and storage, disposal, and landfilling requirements for asbestos-containing waste materials (ACWM). All operators are required to maintain records, including waste shipment records, and are required to use appropriate warning labels, signs, and markings.
AHERA
The Asbestos Hazard Emergency Response Act (AHERA) requires performance of asbestos surveys and the development of Asbestos Management Plans for all of the nation's primary and secondary schools. The general procedures mandated under AHERA are considered the industry standard and are applied to all surveys performed.
146
Ellis www.ellisenvironmental.com 310 544 1837
Cal-OSHA
Per Cal-OSHA standards, 1926.1101, Asbestos-Containing Construction Materials (ACCMs) are defined as any material with an asbestos content greater than one-tenth of one percent (>0.1%). Cal-OSHA sets forth work requirements for disturbance of ACCMs including removal operations for all types of ACCMs. The requirements have been classified as Class I, Class II, Class III, or Class IV Asbestos related work. The classes are distinguished by their potential to release fibers. Cal-OSHA prescribes specific engineering controls and work practices for each Class of Asbestos related Work.
1. Class I – This Class refers to removal of ACMs identified as Thermal System Insulation (TSI) or surfacing (sprayed-on or troweled-on) materials. These materials are generally considered friable.
2. Class II – This Class refers to removal of ACMs identified that are not TSI or surfacing materials.
These materials are generally considered non-friable.
3. Class III – This Class refers to repair and maintenance operations of all identified ACMs.
4. Class IV – This Class refers to incidental contact with identified ACMs such as custodial staff.
California Health and Safety Code
The California Health and Safety Code 25915 (former Connelly Bill) requires all building owners in the State of California to provide written notification to employees, tenants, and contractors of the presence and location of ACCMs within their buildings. Some exclusion to the notification rule for restricted access areas is allowed. All documentation related to asbestos surveys (and air monitoring) must be made available to employees, tenants, or contractors for review. ACCMs are defined as any materials with an asbestos content greater than one-tenth of one percent (>0.1%). The California Health and Safety Code also require that a seller with any knowledge of ACMs on a property disclose such information or knowledge to other parties involved in a real estate transaction.
Building Demolition / Renovation
In accordance with the US EPA's NESHAPs regulation and the SCAQMD, all structures planned for renovation or demolition must be surveyed for ACMs prior to the planned renovation or demolition.
Subsequent removal of identified ACMs is also required. Removal involves, to the greatest extent practical, the complete removal, disposal, and replacement, if necessary, of the ACMs. Removal usually also requires encapsulation of the remaining structure to lock down residual fibers which may exist.
Removal of ACMs is required prior to renovation and/or demolition activities. The US EPA and SCAQMD require removal of all RACMs prior to demolition or renovation. RACMs include friable and non-friable (Category I and II) which have or will become friable by demolition or renovation activities. 147
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBSTITUTION PROCEDURES 012500 - 1
SECTION 012500 - SUBSTITUTION PROCEDURES
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section includes administrative and procedural requirements for substitutions.
1.3 DEFINITIONS
A. Substitutions: Changes in products, materials, equipment, and methods of construction from those required by the Contract Documents.
1. Substitutions for Cause: Changes proposed by Contractor that are required due to changed Project conditions, such as unavailability of product, regulatory changes, or unavailability of required warranty terms.
2. Substitutions for Convenience: Changes proposed by Contractor or Owner that are not required to meet other Project requirements but may offer advantage to Contractor or Owner.
1.4 ACTION SUBMITTALS
A. Substitution Requests: Submit documentation identifying product or fabrication or installation method to be replaced. Include Specification Section number and title and Drawing numbers and titles.
1. Substitution Request Form: Use form acceptable to Engineer of Record.
2. Documentation: Show compliance with requirements for substitutions and the following, as applicable:
a. Statement indicating why specified product or fabrication or installation method cannot be provided, if applicable.
b. Coordination of information, including a list of changes or revisions needed to other parts of the Work and to construction performed by Owner and separate contractors that will be necessary to accommodate proposed substitution. c. Detailed comparison of significant qualities of proposed substitutions with those of the Work specified. Include annotated copy of applicable Specification Section.
Significant qualities may include attributes, such as performance, weight, size, durability, visual effect, sustainable design characteristics, warranties, and specific 148
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBSTITUTION PROCEDURES 012500 - 2
features and requirements indicated. Indicate deviations, if any, from the Work specified.
d. Product Data, including drawings and descriptions of products and fabrication and installation procedures.
e. Samples, where applicable or requested.
f. Certificates and qualification data, where applicable or requested. g. List of similar installations for completed projects, with project names and addresses as well as names and addresses of Engineers and owners. h. Material test reports from a qualified testing agency, indicating and interpreting test results for compliance with requirements indicated. i. Research reports evidencing compliance with building code in effect for Project. j. Detailed comparison of Contractor's construction schedule using proposed substitutions with products specified for the Work, including effect on the overall Contract Time. If specified product or method of construction cannot be provided within the Contract Time, include letter from manufacturer, on manufacturer's letterhead, stating date of receipt of purchase order, lack of availability, or delays in delivery.
k. Cost information, including a proposal of change, if any, in the Contract Sum. l. Contractor's certification that proposed substitution complies with requirements in the Contract Documents, except as indicated in substitution request, is compatible with related materials and is appropriate for applications indicated. m. Contractor's waiver of rights to additional payment or time that may subsequently become necessary because of failure of proposed substitution to produce indicated results.
3. Engineer's Action: If necessary, Engineer will request additional information or documentation for evaluation within 7 days of receipt of a request for substitution.
Engineer will notify Contractor of acceptance or rejection of proposed substitution within 15 days of receipt of request, or 7 days of receipt of additional information or documentation, whichever is later.
1.5 QUALITY ASSURANCE
A. Compatibility of Substitutions: Investigate and document compatibility of proposed substitution with related products and materials. Engage a qualified testing agency to perform compatibility tests recommended by manufacturers.
1.6 PROCEDURES
A. Coordination: Revise or adjust affected work as necessary to integrate work of the approved substitutions.
1.7 SUBSTITUTIONS
A. Substitutions for Cause: Submit requests for substitution immediately on discovery of need for change, but not later than 15 days prior to time required for preparation and review of related submittals.
149
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBSTITUTION PROCEDURES 012500 - 3
1. Conditions: Engineer will consider Contractor's request for substitution when the following conditions are satisfied. If the following conditions are not satisfied, Engineer will return requests without action, except to record noncompliance with these requirements:
a. Requested substitution is consistent with the Contract Documents and will produce indicated results.
b. Substitution request is fully documented and properly submitted. c. Requested substitution will not adversely affect Contractor's construction schedule. d. Requested substitution has received necessary approvals of authorities having jurisdiction.
e. Requested substitution is compatible with other portions of the Work. f. Requested substitution has been coordinated with other portions of the Work. g. Requested substitution provides specified warranty.
h. If requested substitution involves more than one contractor, requested substitution has been coordinated with other portions of the Work, is uniform and consistent, is compatible with other products, and is acceptable to all contractors involved.
B. Substitutions for Convenience: Not allowed unless otherwise indicated.
PART 2 - PRODUCTS (Not Used)
PART 3 - EXECUTION (Not Used)
END OF SECTION 012500
150
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBMITTAL PROCEDURES 013300 - 1
SECTION 013300 - SUBMITTAL PROCEDURES
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Submittal schedule requirements.
2. Administrative and procedural requirements for submittals.
B. Related Requirements:
1. Section 014000 "Quality Requirements" for submitting test and inspection reports, and schedule of tests and inspections.
2. Section 017700 "Closeout Procedures" for submitting closeout submittals and maintenance material submittals.
3. Section 017823 "Operation and Maintenance Data" for submitting operation and maintenance manuals.
4. Section 017839 "Project Record Documents" for submitting record Drawings, record Specifications, and record Product Data.
5. Section 017900 "Demonstration and Training" for submitting video recordings of demonstration of equipment and training of Owner's personnel.
1.2 DEFINITIONS
A. Action Submittals: Written and graphic information and physical samples that require Engineer's action. Action submittals are those submittals indicated in individual Specification Sections as "action submittals."
B. Informational Submittals: Written and graphic information and physical samples that do not require Engineer's responsive action. Submittals may be rejected for not complying with requirements. Informational submittals are those submittals indicated in individual Specification Sections as "informational submittals."
1.3 SUBMITTAL SCHEDULE
A. Submittal Schedule: Submit, as an action submittal, a list of submittals, arranged in chronological order by dates required by construction schedule. Include time required for review, ordering, manufacturing, fabrication, and delivery when establishing dates. Include additional time required for making corrections or revisions to submittals noted by Engineer and additional time for handling and reviewing submittals required by those corrections.
1. Coordinate submittal schedule with list of subcontracts, the schedule of values, and Contractor's construction schedule.
151
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBMITTAL PROCEDURES 013300 - 2
2. Initial Submittal Schedule: Submit concurrently with startup construction schedule.
Include submittals required during the first 60 days of construction. List those submittals required to maintain orderly progress of the Work and those required early because of long lead time for manufacture or fabrication.
3. Final Submittal Schedule: Submit concurrently with the first complete submittal of Contractor's construction schedule.
a. Submit revised submittal schedule as required to reflect changes in current status and timing for submittals.
4. Format: Arrange the following information in a tabular format:
a. Scheduled date for first submittal.
b. Specification Section number and title.
c. Submittal Category: Action; informational.
d. Name of subcontractor.
e. Description of the Work covered.
f. Scheduled date for Engineer's final release or approval.
1.4 SUBMITTAL FORMATS
A. Submittal Information: Include the following information in each submittal:
1. Project name.
2. Date.
3. Name of Engineer.
4. Name of Construction Manager.
5. Name of Contractor.
6. Name of firm or entity that prepared submittal.
7. Names of subcontractor, manufacturer, and supplier.
8. Unique submittal number, including revision identifier. Include Specification Section number with sequential alphanumeric identifier and alphanumeric suffix for resubmittals.
9. Category and type of submittal.
10. Submittal purpose and description.
11. Number and title of Specification Section, with paragraph number and generic name for each of multiple items.
12. Drawing number and detail references, as appropriate.
13. Indication of full or partial submittal.
14. Location(s) where product is to be installed, as appropriate.
15. Other necessary identification.
16. Remarks.
17. Signature of transmitter.
B. Options: Identify options requiring selection by Engineer.
C. Deviations and Additional Information: On each submittal, clearly indicate deviations from requirements in the Contract Documents, including minor variations and limitations; include relevant additional information and revisions, other than those requested by Engineer on previous submittals. Indicate by highlighting on each submittal or noting on attached separate sheet.
152
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBMITTAL PROCEDURES 013300 - 3
D. Electronic Submittals: Prepare submittals as PDF package, incorporating complete information into each PDF file. Name PDF file with submittal number.
1.5 SUBMITTAL PROCEDURES
A. Prepare and submit submittals required by individual Specification Sections. Types of submittals are indicated in individual Specification Sections.
1. Email: Prepare submittals as PDF package and transmit to Engineer by sending via email.
Include PDF transmittal form. Include information in email subject line as requested by Engineer.
a. Engineer will return annotated file. Annotate and retain one copy of file as a digital Project Record Document file.
2. Web-Based Project Management Software: Prepare submittals in PDF form, and upload to web-based Project management software website. Enter required data in web-based software site to fully identify submittal.
3. Paper: Prepare submittals in paper form and deliver to Engineer.
B. Coordination: Coordinate preparation and processing of submittals with performance of construction activities.
1. Coordinate each submittal with fabrication, purchasing, testing, delivery, other submittals, and related activities that require sequential activity.
2. Submit all submittal items required for each Specification Section concurrently unless partial submittals for portions of the Work are indicated on approved submittal schedule.
3. Submit action submittals and informational submittals required by the same Specification Section as separate packages under separate transmittals.
4. Coordinate transmittal of submittals for related parts of the Work specified in different Sections, so processing will not be delayed because of need to review submittals concurrently for coordination.
a. Engineer reserves the right to withhold action on a submittal requiring coordination with other submittals until related submittals are received.
C. Processing Time: Allow time for submittal review, including time for resubmittals, as follows.
Time for review shall commence on Engineer's receipt of submittal. No extension of the Contract Time will be authorized because of failure to transmit submittals enough in advance of the Work to permit processing, including resubmittals.
1. Initial Review: Allow 15 days for initial review of each submittal. Allow additional time if coordination with subsequent submittals is required. Engineer will advise Contractor when a submittal being processed must be delayed for coordination.
2. Intermediate Review: If intermediate submittal is necessary, process it in same manner as initial submittal.
3. Resubmittal Review: Allow 15 days for review of each resubmittal.
4. Sequential Review: Where sequential review of submittals by Engineer's consultants, Owner, or other parties is indicated, allow 21 days for initial review of each submittal. 153
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBMITTAL PROCEDURES 013300 - 4
5. Concurrent Consultant Review: Where the Contract Documents indicate that submittals may be transmitted simultaneously to Engineer and to Engineer's consultants, allow 15 days for review of each submittal. Submittal will be returned to Engineer before being returned to Contractor.
a. Submit one copy of submittal to concurrent reviewer in addition to specified number of copies to Engineer.
D. Resubmittals: Make resubmittals in same form and number of copies as initial submittal.
1. Note date and content of previous submittal.
2. Note date and content of revision in label or title block, and clearly indicate extent of revision.
3. Resubmit submittals until they are marked with approval notation from Engineer's action stamp.
E. Distribution: Furnish copies of final submittals to manufacturers, subcontractors, suppliers, fabricators, installers, authorities having jurisdiction, and others as necessary for performance of construction activities. Show distribution on transmittal forms.
F. Use for Construction: Retain complete copies of submittals on Project site. Use only final action submittals that are marked with approval notation from Engineer's action stamp.
1.6 SUBMITTAL REQUIREMENTS
A. Product Data: Collect information into a single submittal for each element of construction and type of product or equipment.
1. If information must be specially prepared for submittal because standard published data are unsuitable for use, submit as Shop Drawings, not as Product Data.
2. Mark each copy of each submittal to show which products and options are applicable.
3. Include the following information, as applicable:
a. Manufacturer's catalog cuts.
b. Manufacturer's product specifications.
c. Standard color charts.
d. Statement of compliance with specified referenced standards. e. Testing by recognized testing agency.
f. Application of testing agency labels and seals.
g. Notation of coordination requirements.
h. Availability and delivery time information.
4. For equipment, include the following in addition to the above, as applicable:
a. Wiring diagrams that show factory-installed wiring.
b. Printed performance curves.
c. Operational range diagrams.
d. Clearances required to other construction, if not indicated on accompanying Shop Drawings.
154
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBMITTAL PROCEDURES 013300 - 5
5. Submit Product Data before Shop Drawings, and before or concurrently with Samples.
B. Shop Drawings: Prepare Project-specific information, drawn accurately to scale. Do not base Shop Drawings on reproductions of the Contract Documents or standard printed data unless submittal based on Engineer's digital data drawing files is otherwise permitted.
1. Preparation: Fully illustrate requirements in the Contract Documents. Include the following information, as applicable:
a. Identification of products.
b. Schedules.
c. Compliance with specified standards.
d. Notation of coordination requirements.
e. Notation of dimensions established by field measurement. f. Relationship and attachment to adjoining construction clearly indicated. g. Seal and signature of professional engineer if specified.
2. Paper Sheet Size: Except for templates, patterns, and similar full-size Drawings, submit Shop Drawings on sheets at least 8-1/2 by 11 inches (215 by 280 mm), but no larger than 30 by 42 inches (750 by 1067 mm).
a. Two opaque (bond) copies of each submittal. Engineer will return one copy.
C. Samples: Submit Samples for review of type, color, pattern, and texture for a check of these characteristics with other materials.
1. Transmit Samples that contain multiple, related components, such as accessories together in one submittal package.
2. Identification: Permanently attach label on unexposed side of Samples that includes the following:
a. Project name and submittal number.
b. Generic description of Sample.
c. Product name and name of manufacturer.
d. Sample source.
e. Number and title of applicable Specification Section. f. Specification paragraph number and generic name of each item.
3. Email Transmittal: Provide PDF transmittal. Include digital image file illustrating Sample characteristics and identification information for record.
4. Web-Based Project Management Software: Prepare submittals in PDF form, and upload to web-based Project software website. Enter required data in web-based software site to fully identify submittal.
5. Disposition: Maintain sets of approved Samples at Project site, available for qualitycontrol comparisons throughout the course of construction activity. Sample sets may be used to determine final acceptance of construction associated with each set.
6. Samples for Initial Selection: Submit manufacturer's color charts consisting of units or sections of units, showing the full range of colors, textures, and patterns available. 155
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBMITTAL PROCEDURES 013300 - 6
a. Number of Samples: Submit one full set(s) of available choices where color, pattern, texture, or similar characteristics are required to be selected from manufacturer's product line. Engineer will return submittal with options selected.
7. Samples for Verification: Submit full-size units or Samples of size indicated, prepared from same material to be used for the Work, cured and finished in manner specified, and physically identical with material or product proposed for use, and that show full range of color and texture variations expected. Samples include, but are not limited to, the following: partial sections of manufactured or fabricated components; small cuts or containers of materials; complete units of repetitively used materials; swatches showing color, texture, and pattern; color range sets; and components used for independent testing and inspection.
a. Number of Samples: Submit three sets of Samples. Engineer will retain two Sample sets; remainder will be returned.
1) Submit a single Sample where assembly details, workmanship, fabrication techniques, connections, operation, and other similar characteristics are to be demonstrated.
2) If variation in color, pattern, texture, or other characteristic is inherent in material or product represented by a Sample, submit at least three sets of paired units that show approximate limits of variations.
D. Product Schedule: As required in individual Specification Sections, prepare a written summary indicating types of products required for the Work and their intended location. Include the following information in tabular form:
1. Type of product. Include unique identifier for each product indicated in the Contract Documents or assigned by Contractor if none is indicated.
2. Manufacturer and product name, and model number if applicable.
3. Number and name of room or space.
4. Location within room or space.
E. Qualification Data: Prepare written information that demonstrates capabilities and experience of firm or person. Include lists of completed projects with project names and addresses, contact information of Engineers and owners, and other information specified.
F. Design Data: Prepare and submit written and graphic information indicating compliance with indicated performance and design criteria in individual Specification Sections. Include list of assumptions and summary of loads. Include load diagrams if applicable. Provide name and version of software, if any, used for calculations. Number each page of submittal.
G. Certificates:
1. Certificates and Certifications Submittals: Submit a statement that includes signature of entity responsible for preparing certification. Certificates and certifications shall be signed by an officer or other individual authorized to sign documents on behalf of that entity. Provide a notarized signature where indicated.
2. Installer Certificates: Submit written statements on manufacturer's letterhead, certifying that Installer complies with requirements in the Contract Documents and, where required, is authorized by manufacturer for this specific Project. 156
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBMITTAL PROCEDURES 013300 - 7
3. Manufacturer Certificates: Submit written statements on manufacturer's letterhead, certifying that manufacturer complies with requirements in the Contract Documents.
Include evidence of manufacturing experience where required.
4. Material Certificates: Submit written statements on manufacturer's letterhead, certifying that material complies with requirements in the Contract Documents.
5. Product Certificates: Submit written statements on manufacturer's letterhead, certifying that product complies with requirements in the Contract Documents.
6. Welding Certificates: Prepare written certification that welding procedures and personnel comply with requirements in the Contract Documents. Submit record of AWS B2.1/B2.1M on AWS forms. Include names of firms and personnel certified.
H. Test and Research Reports:
1. Compatibility Test Reports: Submit reports written by a qualified testing agency, on testing agency's standard form, indicating and interpreting results of compatibility tests performed before installation of product. Include written recommendations for substrate preparation and primers required.
2. Field Test Reports: Submit written reports indicating and interpreting results of field tests performed either during installation of product or after product is installed in its final location, for compliance with requirements in the Contract Documents.
3. Material Test Reports: Submit reports written by a qualified testing agency, on testing agency's standard form, indicating and interpreting test results of material for compliance with requirements in the Contract Documents.
4. Preconstruction Test Reports: Submit reports written by a qualified testing agency, on testing agency's standard form, indicating and interpreting results of tests performed before installation of product, for compliance with performance requirements in the Contract Documents.
5. Product Test Reports: Submit written reports indicating that current product produced by manufacturer complies with requirements in the Contract Documents. Base reports on evaluation of tests performed by manufacturer and witnessed by a qualified testing agency, or on comprehensive tests performed by a qualified testing agency.
6. Research Reports: Submit written evidence, from a model code organization acceptable to authorities having jurisdiction, that product complies with building code in effect for Project. Include the following information:
a. Name of evaluation organization.
b. Date of evaluation.
c. Time period when report is in effect.
d. Product and manufacturers' names.
e. Description of product.
f. Test procedures and results.
g. Limitations of use.
1.7 DELEGATED DESIGN SERVICES
A. Performance and Design Criteria: Where professional design services or certifications by a design professional are specifically required of Contractor by the Contract Documents, provide products and systems complying with specific performance and design criteria indicated. 157
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBMITTAL PROCEDURES 013300 - 8
1. If criteria indicated are insufficient to perform services or certification required, submit a written request for additional information to Engineer.
B. Delegated Design Services Certification: In addition to Shop Drawings, Product Data, and other required submittals, submit digitally signed PDF file and two paper copies of certificate, signed and sealed by the responsible design professional, for each product and system specifically assigned to Contractor to be designed or certified by a design professional.
1. Indicate that products and systems comply with performance and design criteria in the Contract Documents. Include list of codes, loads, and other factors used in performing these services.
1.8 CONTRACTOR'S REVIEW
A. Action Submittals and Informational Submittals: Review each submittal and check for coordination with other Work of the Contract and for compliance with the Contract Documents.
Note corrections and field dimensions. Mark with approval stamp before submitting to Engineer.
B. Contractor's Approval: Indicate Contractor's approval for each submittal with a uniform approval stamp. Include name of reviewer, date of Contractor's approval, and statement certifying that submittal has been reviewed, checked, and approved for compliance with the Contract Documents.
1. Engineer will not review submittals received from Contractor that do not have Contractor's review and approval.
1.9 ENGINEER'S REVIEW
A. Action Submittals: Engineer will review each submittal, indicate corrections or revisions required, and return.
1. PDF Submittals: Engineer will indicate, via markup on each submittal, the appropriate action.
2. Submittals by Web-Based Project Management Software: Engineer will indicate, on Project management software website, the appropriate action.
B. Informational Submittals: Engineer will review each submittal and will not return it, or will return it if it does not comply with requirements. Engineer will forward each submittal to appropriate party.
C. Partial submittals prepared for a portion of the Work will be reviewed when use of partial submittals has received prior approval from Engineer.
D. Incomplete submittals are unacceptable, will be considered nonresponsive, and will be returned for resubmittal without review.
E. Engineer will discard submittals received from sources other than Contractor. 158
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SUBMITTAL PROCEDURES 013300 - 9
F. Submittals not required by the Contract Documents will be returned by Engineer without action.
PART 2 - PRODUCTS (Not Used)
PART 3 - EXECUTION (Not Used)
END OF SECTION 013300
159
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
ALTERATION PROJECT PROCEDURES 013516 - 1
SECTION 013516 - ALTERATION PROJECT PROCEDURES
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes special procedures for alteration work.
1.2 DEFINITIONS
A. Alteration Work: This term includes remodeling, renovation, repair, and maintenance work performed within existing spaces or on existing surfaces as part of the Project.
B. Consolidate: To strengthen loose or deteriorated materials in place.
C. Design Reference Sample: A sample that represents the Engineer's prebid selection of work to be matched; it may be existing work or work specially produced for the Project.
D. Dismantle: To remove by disassembling or detaching an item from a surface, using gentle methods and equipment to prevent damage to the item and surfaces; disposing of items unless indicated to be salvaged or reinstalled.
E. Match: To blend with adjacent construction and manifest no apparent difference in material type, species, cut, form, detail, color, grain, texture, or finish; as approved by Engineer.
F. Refinish: To remove existing finishes to base material and apply new finish to match original, or as otherwise indicated.
G. Repair: To correct damage and defects, retaining existing materials, features, and finishes. This includes patching, piecing-in, splicing, consolidating, or otherwise reinforcing or upgrading materials.
H. Replace: To remove, duplicate, and reinstall entire item with new material. The original item is the pattern for creating duplicates unless otherwise indicated.
I. Replicate: To reproduce in exact detail, materials, and finish unless otherwise indicated.
J. Reproduce: To fabricate a new item, accurate in detail to the original, and from either the same or a similar material as the original, unless otherwise indicated.
K. Retain: To keep an element or detail secure and intact.
L. Strip: To remove existing finish down to base material unless otherwise indicated. 160
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
ALTERATION PROJECT PROCEDURES 013516 - 2
1.3 COORDINATION
A. Alteration Work Subschedule: A construction schedule coordinating the sequencing and scheduling of alteration work for entire Project, including each activity to be performed, and based on Contractor's Construction Schedule. Secure time commitments for performing critical construction activities from separate entities responsible for alteration work.
1. Schedule construction operations in sequence required to obtain best Work results.
2. Coordinate sequence of alteration work activities to accommodate the following:
a. Owner's continuing occupancy of portions of existing building. b. Owner's partial occupancy of completed Work.
c. Other known work in progress.
d. Tests and inspections.
3. Detail sequence of alteration work, with start and end dates.
4. Utility Services: Indicate how long utility services will be interrupted. Coordinate shutoff, capping, and continuation of utility services.
5. Use of elevator and stairs.
6. Equipment Data: List gross loaded weight, axle-load distribution, and wheel-base dimension data for mobile and heavy equipment proposed for use in existing structure.
Do not use such equipment without certification from Contractor's professional engineer that the structure can support the imposed loadings without damage.
1.4 PROJECT MEETINGS FOR ALTERATION WORK
A. Preliminary Conference for Alteration Work: Before starting alteration work, conduct conference at Project site.
1. Attendees: In addition to representatives of Owner, Engineer, and Contractor, testing service representative, specialists, and chemical-cleaner manufacturer(s) shall be represented at the meeting.
2. Agenda: Discuss items of significance that could affect progress of alteration work, including review of the following:
a. Alteration Work Subschedule: Discuss and finalize; verify availability of materials, specialists' personnel, equipment, and facilities needed to make progress and avoid delays.
b. Fire-prevention plan.
c. Governing regulations.
d. Areas where existing construction is to remain and the required protection. e. Hauling routes.
f. Sequence of alteration work operations.
g. Storage, protection, and accounting for salvaged and specially fabricated items. h. Existing conditions, staging, and structural loading limitations of areas where materials are stored.
i. Qualifications of personnel assigned to alteration work and assigned duties. j. Requirements for extent and quality of work, tolerances, and required clearances. 161
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
ALTERATION PROJECT PROCEDURES 013516 - 3
k. Embedded work such as flashings and lintels, special details, collection of waste, protection of occupants and the public, and condition of other construction that affects the Work or will affect the work.
3. Reporting: Record conference results and distribute copies to everyone in attendance and to others affected by decisions or actions resulting from conference.
B. Coordination Meetings: Conduct coordination meetings specifically for alteration work at weekly intervals. Coordination meetings are in addition to specific meetings held for other purposes, such as progress meetings and preinstallation conferences.
1. Attendees: In addition to representatives of Owner, Engineer, and Contractor, each specialist, supplier, installer, and other entity concerned with progress or involved in planning, coordination, or performance of alteration work activities shall be represented at these meetings. All participants at conference shall be familiar with Project and authorized to conclude matters relating to alteration work.
2. Agenda: Review and correct or approve minutes of previous coordination meeting.
Review other items of significance that could affect progress of alteration work. Include topics for discussion as appropriate to status of Project. a. Alteration Work Subschedule: Review progress since last coordination meeting.
Determine whether each schedule item is on time, ahead of schedule, or behind schedule. Determine how construction behind schedule will be expedited with retention of quality; secure commitments from parties involved to do so. Discuss whether schedule revisions are required to ensure that current and subsequent activities are completed within the Contract Time.
b. Schedule Updating: Revise Contractor's Alteration Work Subschedule after each coordination meeting where revisions to schedule have been made or recognized.
Issue revised schedule concurrently with report of each meeting. c. Review present and future needs of each entity present, including review items listed in the "Preliminary Conference for Alteration Work" Paragraph in this article and the following:
1) Interface requirements of alteration work with other Project Work. 2) Status of submittals for alteration work.
3) Access to alteration work locations.
4) Effectiveness of fire-prevention plan.
5) Quality and work standards of alteration work.
6) Change Orders for alteration work.
3. Reporting: Record meeting results and distribute copies to everyone in attendance and to others affected by decisions or actions resulting from each meeting.
1.5 MATERIALS OWNERSHIP
A. Historic items, relics, and similar objects including, but not limited to, cornerstones and their contents, commemorative plaques and tablets, antiques, and other items of interest or value to Owner that may be encountered or uncovered during the Work, regardless of whether they were previously documented, remain Owner's property.
162
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
ALTERATION PROJECT PROCEDURES 013516 - 4
1. Carefully dismantle and salvage each item or object in a manner to prevent damage and protect it from damage, then promptly deliver it to Owner where directed at Project site.
1.6 INFORMATIONAL SUBMITTALS
A. Alteration Work Subschedule:
1. Submit alteration work subschedule within seven days of date established for commencement of alteration work.
B. Preconstruction Documentation: Show preexisting conditions of adjoining construction and site improvements that are to remain, including finish surfaces, that might be misconstrued as damage caused by Contractor's alteration work operations.
C. Alteration Work Program: Submit 30 days before work begins.
D. Fire-Prevention Plan: Submit 30 days before work begins.
1.7 QUALITY ASSURANCE
A. Alteration Work Program: Prepare a written plan for alteration work for whole Project, including each phase or process and protection of surrounding materials during operations.
Show compliance with indicated methods and procedures specified in this and other Sections.
Coordinate this whole-Project alteration work program with specific requirements of programs required in other alteration work Sections.
1. Dust and Noise Control: Include locations of proposed temporary dust- and noise-control partitions and means of egress from occupied areas coordinated with continuing on-site operations and other known work in progress.
2. Debris Hauling: Include plans clearly marked to show debris hauling routes, turning radii, and locations and details of temporary protective barriers.
B. Fire-Prevention Plan: Prepare a written plan for preventing fires during the Work, including placement of fire extinguishers, fire blankets, rag buckets, and other fire-control devices during each phase or process. Coordinate plan with Owner's fire-protection equipment and requirements. Include fire-watch personnel's training, duties, and authority to enforce fire safety.
C. Safety and Health Standard: Comply with ANSI/ASSP A10.6.
1.8 STORAGE AND HANDLING OF SALVAGED MATERIALS
A. Salvaged Materials:
1. Clean loose dirt and debris from salvaged items unless more extensive cleaning is indicated.
2. Pack or crate items after cleaning; cushion against damage during handling. Label contents of containers.
163
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
ALTERATION PROJECT PROCEDURES 013516 - 5
3. Store items in a secure area until delivery to Owner.
4. Transport items to Owner's storage area designated by Owner.
5. Protect items from damage during transport and storage.
B. Salvaged Materials for Reinstallation:
1. Repair and clean items for reuse as indicated.
2. Pack or crate items after cleaning and repairing; cushion against damage during handling.
Label contents of containers.
3. Protect items from damage during transport and storage.
4. Reinstall items in locations indicated. Comply with installation requirements for new materials and equipment unless otherwise indicated. Provide connections, supports, and miscellaneous materials to make items functional for use indicated.
C. Existing Materials to Remain: Protect construction indicated to remain against damage and soiling from construction work. Where permitted by Engineer, items may be dismantled and taken to a suitable, protected storage location during construction work and reinstalled in their original locations after alteration and other construction work in the vicinity is complete.
D. Storage: Catalog and store items within a weathertight enclosure where they are protected from moisture, weather, condensation, and freezing temperatures.
1. Identify each item for reinstallation with a nonpermanent mark to document its original location. Indicate original locations on plans, elevations, sections, or photographs by annotating the identifying marks.
2. Secure stored materials to protect from theft.
3. Control humidity so that it does not exceed 85 percent. Maintain temperatures 5 deg F (3 deg C) or more above the dew point.
E. Storage Space:
1. Arrange for off-site locations for storage and protection of salvaged material that cannot be stored and protected on-site.
1.9 FIELD CONDITIONS
A. Survey of Existing Conditions: Record existing conditions that affect the Work by use of measured drawings and preconstruction photographs.
B. Discrepancies: Notify Engineer of discrepancies between existing conditions and Drawings before proceeding with removal and dismantling work.
C. Size Limitations in Existing Spaces: Materials, products, and equipment used for performing the Work and for transporting debris, materials, and products shall be of sizes that clear surfaces within existing spaces, areas, rooms, and openings, including temporary protection, by 12 inches (300 mm) or more.
164
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
ALTERATION PROJECT PROCEDURES 013516 - 6
PART 2 - PRODUCTS - (Not Used)
PART 3 - EXECUTION
3.1 PROTECTION
A. Protect persons, motor vehicles, surrounding surfaces of building, building site, plants, and surrounding buildings from harm resulting from alteration work.
1. Use only proven protection methods, appropriate to each area and surface being protected.
2. Provide temporary barricades, barriers, and directional signage to exclude the public from areas where alteration work is being performed.
3. Erect temporary barriers to form and maintain fire-egress routes.
4. Erect temporary protective covers over walkways and at points of pedestrian and vehicular entrance and exit that must remain in service during alteration work.
5. Contain dust and debris generated by alteration work, and prevent it from reaching the public or adjacent surfaces.
6. Provide shoring, bracing, and supports as necessary. Do not overload structural elements.
7. Protect floors and other surfaces along hauling routes from damage, wear, and staining.
8. Provide supplemental sound-control treatment to isolate demolition work from other areas of the building.
B. Temporary Protection of Materials to Remain:
1. Protect existing materials with temporary protections and construction. Do not remove existing materials unless otherwise indicated.
2. Do not attach temporary protection to existing surfaces except as indicated as part of the alteration work program.
C. Comply with each product manufacturer's written instructions for protections and precautions.
Protect against adverse effects of products and procedures on people and adjacent materials, components, and vegetation.
D. Utility and Communications Services:
1. Notify Owner, Engineer, authorities having jurisdiction, and entities owning or controlling wires, conduits, pipes, and other services affected by alteration work before commencing operations.
2. Disconnect and cap pipes and services as required by authorities having jurisdiction, as required for alteration work.
3. Maintain existing services unless otherwise indicated; keep in service, and protect against damage during operations. Provide temporary services during interruptions to existing utilities.
E. Existing Drains: Prior to the start of work in an area, test drainage system to ensure that it is functioning properly. Notify Engineer immediately of inadequate drainage or blockage. Do not begin work in an area until the drainage system is functioning properly. 165
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
ALTERATION PROJECT PROCEDURES 013516 - 7
1. Prevent solids such as adhesive or mortar residue or other debris from entering the drainage system. Clean out drains and drain lines that become sluggish or blocked by sand or other materials resulting from alteration work.
2. Protect drains from pollutants. Block drains or filter out sediments, allowing only clean water to pass.
3.2 PROTECTION FROM FIRE
A. General: Follow fire-prevention plan and the following:
1. Comply with NFPA 241 requirements unless otherwise indicated. Perform duties titled "Owner's Responsibility for Fire Protection."
2. Remove and keep area free of combustibles, including rubbish, paper, waste, and chemicals, unless necessary for the immediate work.
a. If combustible material cannot be removed, provide fire blankets to cover such materials.
B. Heat-Generating Equipment and Combustible Materials: Comply with the following procedures while performing work with heat-generating equipment or combustible materials, including welding, torch-cutting, soldering, brazing, removing paint with heat, or other operations where open flames or implements using high heat or combustible solvents and chemicals are anticipated:
1. Obtain Owner's approval for operations involving use of open-flame or welding or other high-heat equipment. Notify Owner at least 72 hours before each occurrence, indicating location of such work.
2. As far as practicable, restrict heat-generating equipment to shop areas or outside the building.
3. Do not perform work with heat-generating equipment in or near rooms or in areas where flammable liquids or explosive vapors are present or thought to be present. Use a combustible gas indicator test to ensure that the area is safe.
4. Use fireproof baffles to prevent flames, sparks, hot gases, or other high-temperature material from reaching surrounding combustible material.
5. Prevent the spread of sparks and particles of hot metal through open windows, doors, holes, and cracks in floors, walls, ceilings, roofs, and other openings.
6. Fire Watch: Before working with heat-generating equipment or combustible materials, station personnel to serve as a fire watch at each location where such work is performed.
Fire-watch personnel shall have the authority to enforce fire safety. Station fire watch according to NFPA 51B, NFPA 241, and as follows:
a. Train each fire watch in the proper operation of fire-control equipment and alarms. b. Cease work with heat-generating equipment whenever fire-watch personnel are not present.
C. Fire-Control Devices: Provide and maintain fire extinguishers, fire blankets, and rag buckets for disposal of rags with combustible liquids. Maintain each as suitable for the type of fire risk in each work area. Ensure that nearby personnel and the fire-watch personnel are trained in fireextinguisher and blanket use. 166
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
ALTERATION PROJECT PROCEDURES 013516 - 8
3.3 PROTECTION DURING APPLICATION OF CHEMICALS
A. Protect motor vehicles, surrounding surfaces of building, building site, plants, and surrounding buildings from harm or spillage resulting from applications of chemicals and adhesives.
B. Cover adjacent surfaces with protective materials that are proven to resist chemicals selected for Project unless chemicals being used will not damage adjacent surfaces as indicated in alteration work program. Use covering materials and masking agents that are waterproof and UV resistant and that will not stain or leave residue on surfaces to which they are applied. Apply protective materials according to manufacturer's written instructions. Do not apply liquid masking agents or adhesives to painted or porous surfaces. When no longer needed, promptly remove protective materials.
C. Do not apply chemicals during winds of sufficient force to spread them to unprotected surfaces.
D. Neutralize alkaline and acid wastes and legally dispose of off Owner's property.
E. Collect and dispose of runoff from chemical operations by legal means and in a manner that prevents soil contamination, soil erosion, undermining of paving and foundations, damage to landscaping, or water penetration into building interior.
3.4 GENERAL ALTERATION WORK
A. Have specialty work performed only by qualified specialists.
B. Ensure that supervisory personnel are present when work begins and during its progress.
C. Record existing work before each procedure (preconstruction), and record progress during the work. Use digital preconstruction documentation photographs. Comply with requirements in Section 013233 "Photographic Documentation."
D. Perform surveys of Project site as the Work progresses to detect hazards resulting from alterations.
E. Notify Engineer of visible changes in the integrity of material or components whether from environmental causes including biological attack, UV degradation, freezing, or thawing or from structural defects including cracks, movement, or distortion.
1. Do not proceed with the work in question until directed by Engineer.
END OF SECTION 013516
167
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
QUALITY REQUIREMENTS 014000 - 1
SECTION 014000 - QUALITY REQUIREMENTS
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes administrative and procedural requirements for quality assurance and quality control.
B. Testing and inspection services are required to verify compliance with requirements specified or indicated. These services do not relieve Contractor of responsibility for compliance with the Contract Document requirements.
1. Specific quality-assurance and quality-control requirements for individual work results are specified in their respective Specification Sections. Requirements in individual Sections may also cover production of standard products.
2. Specified tests, inspections, and related actions do not limit Contractor's other qualityassurance and quality-control procedures that facilitate compliance with the Contract Document requirements.
3. Requirements for Contractor to provide quality-assurance and quality-control services required by Architect, Owner, Commissioning Authority or authorities having jurisdiction are not limited by provisions of this Section.
1.2 DEFINITIONS
A. Experienced: When used with an entity or individual, "experienced," unless otherwise further described, means having successfully completed a minimum of five previous projects similar in nature, size, and extent to this Project; being familiar with special requirements indicated; and having complied with requirements of authorities having jurisdiction.
B. Field Quality-Control Tests and Inspections: Tests and inspections that are performed on-site for installation of the Work and for completed Work.
C. Installer/Applicator/Erector: Contractor or another entity engaged by Contractor as an employee, subcontractor, or sub-subcontractor, to perform a particular construction operation, including installation, erection, application, assembly, and similar operations.
1. Use of trade-specific terminology in referring to a Work result does not require that certain construction activities specified apply exclusively to specific trade(s).
D. Preconstruction Testing: Tests and inspections performed specifically for Project before products and materials are incorporated into the Work, to verify performance or compliance with specified criteria. Unless otherwise indicated, copies of reports of tests or inspections performed for other than the Project do not meet this definition.
E. Product Tests: Tests and inspections that are performed by a nationally recognized testing laboratory (NRTL) according to 29 CFR 1910.7, by a testing agency accredited according to 168
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
QUALITY REQUIREMENTS 014000 - 2
NIST's National Voluntary Laboratory Accreditation Program (NVLAP), or by a testing agency qualified to conduct product testing and acceptable to authorities having jurisdiction, to establish product performance and compliance with specified requirements.
F. Source Quality-Control Tests and Inspections: Tests and inspections that are performed at the source (e.g., plant, mill, factory, or shop).
G. Testing Agency: An entity engaged to perform specific tests, inspections, or both. The term "testing laboratory" has the same meaning as the term "testing agency." H. Quality-Assurance Services: Activities, actions, and procedures performed before and during execution of the Work, to guard against defects and deficiencies and substantiate that proposed construction will comply with requirements.
I. Quality-Control Services: Tests, inspections, procedures, and related actions during and after execution of the Work, to evaluate that actual products incorporated into the Work and completed construction comply with requirements. Contractor's quality-control services do not include contract administration activities performed by Architect or Construction Manager.
1.3 DELEGATED DESIGN SERVICES
A. Performance and Design Criteria: Where professional design services or certifications by a design professional are specifically required of Contractor by the Contract Documents, provide products and systems complying with specific performance and design criteria indicated.
1. If criteria indicated are not sufficient to perform services or certification required, submit a written request for additional information to Architect.
B. Delegated Design Services Statement: Submit a statement signed and sealed by the responsible design professional, for each product and system specifically assigned to Contractor to be designed or certified by a design professional, indicating that the products and systems are in compliance with performance and design criteria indicated. Include list of codes, loads, and other factors used in performing these services.
1.4 CONFLICTING REQUIREMENTS
A. Conflicting Standards and Other Requirements: If compliance with two or more standards or requirements is specified and the standards or requirements establish different or conflicting requirements for minimum quantities or quality levels, inform the Architect regarding the conflict and obtain clarification prior to proceeding with the Work. Refer conflicting requirements that are different, but apparently equal, to Architect for clarification before proceeding.
B. Minimum Quantity or Quality Levels: The quantity or quality level shown or specified is the minimum provided or performed. The actual installation may comply exactly with the minimum quantity or quality specified, or it may exceed the minimum within reasonable limits. To comply with these requirements, indicated numeric values are minimum or maximum, as appropriate, for the context of requirements. Refer uncertainties to Architect for a decision before proceeding.
169
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
QUALITY REQUIREMENTS 014000 - 3
1.5 INFORMATIONAL SUBMITTALS
A. Contractor's Quality-Control Plan: For quality-assurance and quality-control activities and responsibilities.
B. Qualification Data: For Contractor's quality-control personnel.
C. Contractor's Statement of Responsibility: When required by authorities having jurisdiction, submit copy of written statement of responsibility submitted to authorities having jurisdiction before starting work on the following systems:
1. Seismic-force-resisting system, designated seismic system, or component listed in the Statement of Special Inspections.
2. Primary wind-force-resisting system or a wind-resisting component listed in the Statement of Special Inspections.
D. Testing Agency Qualifications: For testing agencies specified in "Quality Assurance" Article to demonstrate their capabilities and experience. Include proof of qualifications in the form of a recent report on the inspection of the testing agency by a recognized authority.
E. Schedule of Tests and Inspections: Prepare in tabular form and include the following:
1. Specification Section number and title.
2. Entity responsible for performing tests and inspections.
3. Description of test and inspection.
4. Identification of applicable standards.
5. Identification of test and inspection methods.
6. Number of tests and inspections required.
7. Time schedule or time span for tests and inspections.
8. Requirements for obtaining samples.
9. Unique characteristics of each quality-control service.
F. Reports: Prepare and submit certified written reports and documents as specified.
G. Permits, Licenses, and Certificates: For Owner's record, submit copies of permits, licenses, certifications, inspection reports, releases, jurisdictional settlements, notices, receipts for fee payments, judgments, correspondence, records, and similar documents established for compliance with standards and regulations bearing on performance of the Work.
1.6 CONTRACTOR'S QUALITY-CONTROL PLAN
A. Quality-Control Plan, General: Submit quality-control plan within 10 days of Notice of Award, and not less than five days prior to preconstruction conference. Submit in format acceptable to Architect. Identify personnel, procedures, controls, instructions, tests, records, and forms to be used to carry out Contractor's quality-assurance and quality-control responsibilities and to coordinate Owner's quality-assurance and quality-control activities. Coordinate with Contractor's Construction Schedule.
170
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
QUALITY REQUIREMENTS 014000 - 4
B. Quality-Control Personnel Qualifications: Engage qualified personnel trained and experienced in managing and executing quality-assurance and quality-control procedures similar in nature and extent to those required for Project.
1. Project quality-control manager may also serve as Project superintendent.
C. Submittal Procedure: Describe procedures for ensuring compliance with requirements through review and management of submittal process. Indicate qualifications of personnel responsible for submittal review.
D. Testing and Inspection: In quality-control plan, include a comprehensive schedule of Work requiring testing or inspection, including the following:
1. Contractor-performed tests and inspections, including subcontractor-performed tests and inspections. Include required tests and inspections and Contractor-elected tests and inspections. Distinguish source quality-control tests and inspections from field qualitycontrol tests and inspections.
2. Special inspections required by authorities having jurisdiction and indicated on the Statement of Special Inspections.
E. Continuous Inspection of Workmanship: Describe process for continuous inspection during construction to identify and correct deficiencies in workmanship in addition to testing and inspection specified. Indicate types of corrective actions to be required to bring the Work into compliance with standards of workmanship established by Contract requirements and approved mockups.
F. Monitoring and Documentation: Maintain testing and inspection reports, including log of approved and rejected results. Include Work Architect has indicated as nonconforming or defective. Indicate corrective actions taken to bring nonconforming Work into compliance with requirements. Comply with requirements of authorities having jurisdiction.
1.7 REPORTS AND DOCUMENTS
A. Test and Inspection Reports: Prepare and submit certified written reports specified in other Sections. Include the following:
1. Date of issue.
2. Project title and number.
3. Name, address, telephone number, and email address of testing agency.
4. Dates and locations of samples and tests or inspections.
5. Names of individuals making tests and inspections.
6. Description of the Work and test and inspection method.
7. Identification of product and Specification Section.
8. Complete test or inspection data.
9. Test and inspection results and an interpretation of test results.
10. Record of temperature and weather conditions at time of sample-taking and testing and inspection.
11. Comments or professional opinion on whether tested or inspected Work complies with the Contract Document requirements.
12. Name and signature of laboratory inspector.
171
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
QUALITY REQUIREMENTS 014000 - 5
13. Recommendations on retesting and reinspecting.
B. Manufacturer's Technical Representative's Field Reports: Prepare written information documenting manufacturer's technical representative's tests and inspections specified in other Sections. Include the following:
1. Name, address, telephone number, and email address of technical representative making report.
2. Statement on condition of substrates and their acceptability for installation of product.
3. Statement that products at Project site comply with requirements.
4. Summary of installation procedures being followed, whether they comply with requirements and, if not, what corrective action was taken.
5. Results of operational and other tests and a statement of whether observed performance complies with requirements.
6. Statement of whether conditions, products, and installation will affect warranty.
7. Other required items indicated in individual Specification Sections.
C. Factory-Authorized Service Representative's Reports: Prepare written information documenting manufacturer's factory-authorized service representative's tests and inspections specified in other Sections. Include the following:
1. Name, address, telephone number, and email address of factory-authorized service representative making report.
2. Statement that equipment complies with requirements.
3. Results of operational and other tests and a statement of whether observed performance complies with requirements.
4. Statement of whether conditions, products, and installation will affect warranty.
5. Other required items indicated in individual Specification Sections.
1.8 QUALITY ASSURANCE
A. Qualifications paragraphs in this article establish the minimum qualification levels required; individual Specification Sections specify additional requirements.
B. Manufacturer Qualifications: A firm experienced in manufacturing products or systems similar to those indicated for this Project and with a record of successful in-service performance, as well as sufficient production capacity to produce required units. As applicable, procure products from manufacturers able to meet qualification requirements, warranty requirements, and technical or factory-authorized service representative requirements.
C. Fabricator Qualifications: A firm experienced in producing products similar to those indicated for this Project and with a record of successful in-service performance, as well as sufficient production capacity to produce required units.
D. Installer Qualifications: A firm or individual experienced in installing, erecting, applying, or assembling work similar in material, design, and extent to that indicated for this Project, whose work has resulted in construction with a record of successful in-service performance.
E. Professional Engineer Qualifications: A professional engineer who is legally qualified to practice in jurisdiction where Project is located and who is experienced in providing 172
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
QUALITY REQUIREMENTS 014000 - 6
engineering services of the kind indicated. Engineering services are defined as those performed for installations of the system, assembly, or product that is similar in material, design, and extent to those indicated for this Project.
F. Specialists: Certain Specification Sections require that specific construction activities be performed by entities who are recognized experts in those operations. Specialists will satisfy qualification requirements indicated and engage in the activities indicated.
1. Requirements of authorities having jurisdiction supersede requirements for specialists.
G. Testing and Inspecting Agency Qualifications: An NRTL, an NVLAP, or an independent agency with the experience and capability to conduct testing and inspection indicated, as documented in accordance with ASTM E329, and with additional qualifications specified in individual Sections; and, where required by authorities having jurisdiction, that is acceptable to authorities.
H. Manufacturer's Technical Representative Qualifications: An authorized representative of manufacturer who is trained and approved by manufacturer to observe and inspect installation of manufacturer's products that are similar in material, design, and extent to those indicated for this Project.
I. Factory-Authorized Service Representative Qualifications: An authorized representative of manufacturer who is trained and approved by manufacturer to inspect, demonstrate, repair, and perform service on installations of manufacturer's products that are similar in material, design, and extent to those indicated for this Project.
J. Preconstruction Testing: Where testing agency is indicated to perform preconstruction testing for compliance with specified requirements for performance and test methods, comply with the following Contractor's responsibilities, including the following:
1. Provide test specimens representative of proposed products and construction.
2. Submit specimens in a timely manner with sufficient time for testing and analyzing results to prevent delaying the Work.
3. Provide sizes and configurations of test assemblies, mockups, and laboratory mockups to adequately demonstrate capability of products to comply with performance requirements.
4. When testing is complete, remove test specimens and test assemblies; do not reuse products on Project.
5. Testing Agency Responsibilities: Submit a certified written report of each test, inspection, and similar quality-assurance service to Architect and Commissioning Authority, with copy to Contractor. Interpret tests and inspections, and state in each report whether tested and inspected Work complies with or deviates from the Contract Documents.
1.9 QUALITY CONTROL
1. Engage a qualified testing agency to perform quality-control services. a. Contractor will not employ same entity engaged by Owner, unless agreed to in writing by Owner.
173
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
QUALITY REQUIREMENTS 014000 - 7
2. Notify testing agencies at least 24 hours in advance of time when Work that requires testing or inspection will be performed.
3. Where quality-control services are indicated as Contractor's responsibility, submit a certified written report, in duplicate, of each quality-control service.
4. Testing and inspection requested by Contractor and not required by the Contract Documents are Contractor's responsibility.
5. Submit additional copies of each written report directly to authorities having jurisdiction, when they so direct.
B. Retesting/Reinspecting: Regardless of whether original tests or inspections were Contractor's responsibility, provide quality-control services, including retesting and reinspecting, for construction that replaced Work that failed to comply with the Contract Documents.
C. Testing Agency Responsibilities: Cooperate with Architect, Commissioning Authority, and Contractor in performance of duties. Provide qualified personnel to perform required tests and inspections.
1. Notify Architect, Commissioning Authority, and Contractor promptly of irregularities or deficiencies observed in the Work during performance of its services.
2. Determine the locations from which test samples will be taken and in which in-situ tests are conducted.
3. Conduct and interpret tests and inspections, and state in each report whether tested and inspected Work complies with or deviates from requirements.
4. Submit a certified written report, in duplicate, of each test, inspection, and similar quality-control service through Contractor.
5. Do not release, revoke, alter, or increase the Contract Document requirements or approve or accept any portion of the Work.
6. Do not perform duties of Contractor.
D. Manufacturer's Field Services: Where indicated, engage a factory-authorized service representative to inspect field-assembled components and equipment installation, including service connections. Report results in writing as specified in Section 013300 "Submittal Procedures."
E. Manufacturer's Technical Services: Where indicated, engage a manufacturer's technical representative to observe and inspect the Work. Manufacturer's technical representative's services include participation in preinstallation conferences, examination of substrates and conditions, verification of materials, observation of Installer activities, inspection of completed portions of the Work, and submittal of written reports.
F. Contractor's Associated Requirements and Services: Cooperate with agencies and representatives performing required tests, inspections, and similar quality-control services, and provide reasonable auxiliary services as requested. Notify agency sufficiently in advance of operations to permit assignment of personnel. Provide the following:
1. Access to the Work.
2. Incidental labor and facilities necessary to facilitate tests and inspections.
3. Adequate quantities of representative samples of materials that require testing and inspection. Assist agency in obtaining samples.
174
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
QUALITY REQUIREMENTS 014000 - 8
G. Coordination: Coordinate sequence of activities to accommodate required quality-assurance and quality-control services with a minimum of delay and to avoid necessity of removing and replacing construction to accommodate testing and inspection.
1. Schedule times for tests, inspections, obtaining samples, and similar activities.
PART 2 - PRODUCTS (Not Used)
PART 3 - EXECUTION
3.1 TEST AND INSPECTION LOG
A. Test and Inspection Log: Prepare a record of tests and inspections. Include the following:
1. Date test or inspection was conducted.
2. Description of the Work tested or inspected.
3. Date test or inspection results were transmitted to Architect.
4. Identification of testing agency or special inspector conducting test or inspection.
B. Maintain log at Project site. Post changes and revisions as they occur. Provide access to test and inspection log for Architect's, Commissioning Authority's, and authorities' having jurisdiction reference during normal working hours.
1. Submit log at Project closeout as part of Project Record Documents.
3.2 REPAIR AND PROTECTION
A. General: On completion of testing, inspection, sample-taking, and similar services, repair damaged construction and restore substrates and finishes.
1. Provide materials and comply with installation requirements specified in other Specification Sections or matching existing substrates and finishes. Restore patched areas and extend restoration into adjoining areas with durable seams that are as invisible as possible. Comply with the Contract Document requirements for cutting and patching in Section 017300 "Execution."
B. Protect construction exposed by or for quality-control service activities.
C. Repair and protection are Contractor's responsibility, regardless of the assignment of responsibility for quality-control services.
END OF SECTION 014000
175
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXECUTION 017300 - 1
SECTION 017300 - EXECUTION
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes general administrative and procedural requirements governing execution of the Work, including, but not limited to, the following:
1. Construction layout.
2. Field engineering.
3. Installation.
4. Cutting and patching.
5. Coordination of Owner's portion of the Work.
6. Progress cleaning.
7. Starting and adjusting.
8. Protection of installed construction.
9. Correction of the Work.
B. Related Requirements:
1. Section 013300 "Submittal Procedures" for submitting surveys.
2. Section 017700 "Closeout Procedures" for submitting final property survey with Project Record Documents, recording of Owner-accepted deviations from indicated lines and levels, replacing defective work, and final cleaning.
3. Section 024119 "Selective Demolition" for demolition and removal of selected portions of the building.
1.2 DEFINITIONS
A. Cutting: Removal of in-place construction necessary to permit installation or performance of subsequent work.
B. Patching: Fitting and repair work required to restore construction to original conditions after installation of subsequent work.
1.3 PREINSTALLATION MEETINGS
A. Cutting and Patching Conference: Conduct conference at Project site.
1. Prior to commencing work requiring cutting and patching, review extent of cutting and patching anticipated and examine procedures for ensuring satisfactory result from cutting and patching work. Inform Engineer of scheduled meeting. Require representatives of each entity directly concerned with cutting and patching to attend, including the following:
176
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXECUTION 017300 - 2
a. Contractor's superintendent.
b. Trade supervisor responsible for cutting operations. c. Trade supervisor(s) responsible for patching of each type of substrate. d. Mechanical, electrical, and utilities subcontractors' supervisors, to the extent each trade is affected by cutting and patching operations.
2. Review areas of potential interference and conflict. Coordinate procedures and resolve potential conflicts before proceeding.
1.4 QUALITY ASSURANCE
A. Professional Engineer Qualifications: Refer to Section 014000 "Quality Requirements." B. Cutting and Patching: Comply with requirements for and limitations on cutting and patching of construction elements.
1. Structural Elements: When cutting and patching structural elements, or when encountering the need for cutting and patching of elements whose structural function is not known, notify Engineer of locations and details of cutting and await directions from Engineer before proceeding. Shore, brace, and support structural elements during cutting and patching. Do not cut and patch structural elements in a manner that could change their load-carrying capacity or increase deflection.
2. Operational Elements: Do not cut and patch operating elements and related components in a manner that results in reducing their capacity to perform as intended or that results in increased maintenance or decreased operational life or safety.
3. Other Construction Elements: Do not cut and patch other construction elements or components in a manner that could change their load-carrying capacity, that results in reducing their capacity to perform as intended, or that results in increased maintenance or decreased operational life or safety.
4. Visual Elements: Do not cut and patch construction in a manner that results in visual evidence of cutting and patching. Do not cut and patch exposed construction in a manner that would, in Engineer's opinion, reduce the building's aesthetic qualities. Remove and replace construction that has been cut and patched in a visually unsatisfactory manner.
C. Manufacturer's Installation Instructions: Obtain and maintain on-site manufacturer's written recommendations and instructions for installation of specified products and equipment.
PART 2 - PRODUCTS
2.1 MATERIALS
A. Comply with requirements specified in other Sections.
1. For projects requiring compliance with sustainable design and construction practices and procedures, use products for patching that comply with sustainable design requirements. 177
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXECUTION 017300 - 3
B. In-Place Materials: Use materials for patching identical to in-place materials. For exposed surfaces, use materials that visually match in-place adjacent surfaces to the fullest extent possible.
1. If identical materials are unavailable or cannot be used, use materials that, when installed, will provide a match acceptable to Engineer for the visual and functional performance of in-place materials. Use materials that are not considered hazardous.
C. Cleaning Agents: Use cleaning materials and agents recommended by manufacturer or fabricator of the surface to be cleaned. Do not use cleaning agents that are potentially hazardous to health or property or that might damage finished surfaces.
1. Use cleaning products that comply with Green Seal's GS-37, or if GS-37 is not applicable, use products that comply with the California Code of Regulations maximum allowable VOC levels.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Existing Conditions: The existence and location of underground and other utilities and construction indicated as existing are not guaranteed. Before beginning sitework, investigate and verify the existence and location of underground utilities, and other construction affecting the Work.
1. Before construction, verify the location and invert elevation at points of connection of sanitary sewer, storm sewer, gas service piping, and water-service piping; underground electrical services; and other utilities.
2. Furnish location data for work related to Project that must be performed by public utilities serving Project site.
B. Examination and Acceptance of Conditions: Before proceeding with each component of the Work, examine substrates, areas, and conditions, with Installer or Applicator present where indicated, for compliance with requirements for installation tolerances and other conditions affecting performance. Record observations.
1. Examine roughing-in for mechanical and electrical systems to verify actual locations of connections before equipment and fixture installation.
2. Examine walls, floors, and roofs for suitable conditions where products and systems are to be installed.
3. Verify compatibility with and suitability of substrates, including compatibility with existing finishes or primers.
C. Written Report: Where a written report listing conditions detrimental to performance of the Work is required by other Sections, include the following:
1. Description of the Work, including Specification Section number and paragraph, and Drawing sheet number and detail, where applicable.
2. List of detrimental conditions, including substrates. 178
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXECUTION 017300 - 4
3. List of unacceptable installation tolerances.
4. Recommended corrections.
D. Proceed with installation only after unsatisfactory conditions have been corrected. Proceeding with the Work indicates acceptance of surfaces and conditions.
3.2 PREPARATION
A. Existing Utility Information: Furnish information to Owner that is necessary to adjust, move, or relocate existing utility structures, utility poles, lines, services, or other utility appurtenances located in or affected by construction. Coordinate with authorities having jurisdiction.
B. Field Measurements: Take field measurements as required to fit the Work properly. Recheck measurements before installing each product. Where portions of the Work are indicated to fit to other construction, verify dimensions of other construction by field measurements before fabrication. Coordinate fabrication schedule with construction progress to avoid delaying the Work.
C. Space Requirements: Verify space requirements and dimensions of items shown diagrammatically on Drawings.
D. Review of Contract Documents and Field Conditions: Immediately on discovery of the need for clarification of the Contract Documents, submit a request for information to Engineer.
3.3 CONSTRUCTION LAYOUT
A. Verification: Before proceeding to lay out the Work, verify layout information shown on Drawings, in relation to the property survey and existing benchmarks and existing conditions. If discrepancies are discovered, notify Engineer promptly.
3.4 INSTALLATION
A. Locate the Work and components of the Work accurately, in correct alignment and elevation, as indicated.
1. Make vertical work plumb, and make horizontal work level.
2. Where space is limited, install components to maximize space available for maintenance and ease of removal for replacement.
3. Conceal pipes, ducts, and wiring in finished areas unless otherwise indicated.
4. Maintain minimum headroom clearance of 96 inches (2440 mm) in occupied spaces and 90 inches (2300 mm) in unoccupied spaces, unless otherwise indicated on Drawings.
B. Comply with manufacturer's written instructions and recommendations for installing products in applications indicated.
C. Install products at the time and under conditions that will ensure satisfactory results as judged by Engineer. Maintain conditions required for product performance until Substantial Completion.
179
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXECUTION 017300 - 5
D. Conduct construction operations, so no part of the Work is subjected to damaging operations or loading in excess of that expected during normal conditions of occupancy of type expected for Project.
E. Sequence the Work and allow adequate clearances to accommodate movement of construction items on-site and placement in permanent locations.
F. Tools and Equipment: Select tools or equipment that minimize production of excessive noise levels.
G. Templates: Obtain and distribute to the parties involved templates for Work specified to be factory prepared and field installed. Check Shop Drawings of other portions of the Work to confirm that adequate provisions are made for locating and installing products to comply with indicated requirements.
H. Attachment: Provide blocking and attachment plates and anchors and fasteners of adequate size and number to securely anchor each component in place, accurately located and aligned with other portions of the Work. Where size and type of attachments are not indicated, verify size and type required for load conditions with manufacturer.
1. Mounting Heights: Where mounting heights are not indicated, mount components at heights directed by Engineer.
2. Allow for building movement, including thermal expansion and contraction.
3. Coordinate installation of anchorages. Furnish setting drawings, templates, and directions for installing anchorages, including sleeves, concrete inserts, anchor bolts, and items with integral anchors, that are to be embedded in concrete or masonry. Deliver such items to Project site in time for installation.
I. Joints: Make joints of uniform width. Where joint locations in exposed Work are not indicated, arrange joints for the best visual effect, as judged by Engineer. Fit exposed connections together to form hairline joints.
3.5 CUTTING AND PATCHING
A. General: Employ skilled workers to perform cutting and patching. Proceed with cutting and patching at the earliest feasible time, and complete without delay.
1. Cut in-place construction to provide for installation of other components or performance of other construction, and subsequently patch as required to restore surfaces to their original condition.
B. Existing Warranties: Remove, replace, patch, and repair materials and surfaces cut or damaged during installation or cutting and patching operations, by methods and with materials so as not to void existing warranties.
C. Temporary Support: Provide temporary support of Work to be cut.
D. Protection: Protect in-place construction during cutting and patching to prevent damage.
Provide protection from adverse weather conditions for portions of Project that might be exposed during cutting and patching operations.
180
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXECUTION 017300 - 6
E. Adjacent Occupied Areas: Where interference with use of adjoining areas or interruption of free passage to adjoining areas is unavoidable, coordinate cutting and patching in accordance with requirements in Section 011000 "Summary."
F. Existing Utility Services and Mechanical/Electrical Systems: Where existing services/systems are required to be removed, relocated, or abandoned, bypass such services/systems before cutting to prevent interruption to occupied areas.
G. Cutting: Cut in-place construction by sawing, drilling, breaking, chipping, grinding, and similar operations, including excavation, using methods least likely to damage elements retained or adjoining construction. If possible, review proposed procedures with original Installer; comply with original Installer's written recommendations.
1. In general, use hand or small power tools designed for sawing and grinding, not hammering and chopping. Cut holes and slots neatly to minimum size required, and with minimum disturbance of adjacent surfaces. Temporarily cover openings when not in use.
2. Finished Surfaces: Cut or drill from the exposed or finished side into concealed surfaces.
3. Excavating and Backfilling: Comply with requirements in applicable Sections where required by cutting and patching operations.
4. Mechanical and Electrical Services: Cut off pipe or conduit in walls or partitions to be removed. Cap, valve, or plug and seal remaining portion of pipe or conduit to prevent entrance of moisture or other foreign matter after cutting.
5. Proceed with patching after construction operations requiring cutting are complete.
H. Patching: Patch construction by filling, repairing, refinishing, closing up, and similar operations following performance of other Work. Patch with durable seams that are as invisible as practicable, as judged by Engineer. Provide materials and comply with installation requirements specified in other Sections, where applicable.
1. Inspection: Where feasible, test and inspect patched areas after completion to demonstrate physical integrity of installation.
2. Exposed Finishes: Restore exposed finishes of patched areas and extend finish restoration into retained adjoining construction in a manner that will eliminate evidence of patching and refinishing.
a. Clean piping, conduit, and similar features before applying paint or other finishing materials.
b. Restore damaged pipe covering to its original condition.
3. Floors and Walls: Where walls or partitions that are removed extend one finished area into another, patch and repair floor and wall surfaces in the new space. Provide an even surface of uniform finish, color, texture, and appearance. Remove in-place floor and wall coverings and replace with new materials, if necessary, to achieve uniform color and appearance.
a. Where patching occurs in a painted surface, prepare substrate and apply primer and intermediate paint coats appropriate for substrate over the patch, and apply final paint coat over entire unbroken surface containing the patch, corner to corner of wall and edge to edge of ceiling. Provide additional coats until patch blends with adjacent surfaces.
181
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXECUTION 017300 - 7
4. Ceilings: Patch, repair, or rehang in-place ceilings as necessary to provide an even-plane surface of uniform appearance.
5. Exterior Building Enclosure: Patch components in a manner that restores enclosure to a weathertight condition and ensures thermal and moisture integrity of building enclosure.
I. Cleaning: Clean areas and spaces where cutting and patching are performed. Remove paint, mortar, oils, putty, and similar materials from adjacent finished surfaces.
3.6 PROGRESS CLEANING
A. Clean Project site and work areas daily, including common areas. Enforce requirements strictly.
Dispose of materials lawfully.
1. Comply with requirements in NFPA 241 for removal of combustible waste materials and debris.
2. Do not hold waste materials more than seven days during normal weather or three days if the temperature is expected to rise above 80 deg F (27 deg C).
3. Containerize hazardous and unsanitary waste materials separately from other waste. Mark containers appropriately and dispose of legally, in accordance with regulations. a. Use containers intended for holding waste materials of type to be stored.
4. Coordinate progress cleaning for joint-use areas where Contractor and other contractors are working concurrently.
B. Site: Maintain Project site free of waste materials and debris.
C. Work Areas: Clean areas where Work is in progress to the level of cleanliness necessary for proper execution of the Work.
1. Remove liquid spills promptly.
2. Where dust would impair proper execution of the Work, broom-clean or vacuum the entire work area, as appropriate.
D. Installed Work: Keep installed work clean. Clean installed surfaces in accordance with written instructions of manufacturer or fabricator of product installed, using only cleaning materials specifically recommended. If specific cleaning materials are not recommended, use cleaning materials that are not hazardous to health or property and that will not damage exposed surfaces.
E. Concealed Spaces: Remove debris from concealed spaces before enclosing the space.
F. Exposed Surfaces: Clean exposed surfaces and protect as necessary to ensure freedom from damage and deterioration at time of Substantial Completion.
G. Waste Disposal: Do not bury or burn waste materials on-site. Do not wash waste materials down sewers or into waterways. Comply with waste disposal requirements in Section 017419 "Construction Waste Management and Disposal."
182
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXECUTION 017300 - 8
H. During handling and installation, clean and protect construction in progress and adjoining materials already in place. Apply protective covering where required to ensure protection from damage or deterioration at Substantial Completion.
I. Clean and provide maintenance on completed construction as frequently as necessary through the remainder of the construction period. Adjust and lubricate operable components to ensure operability without damaging effects.
J. Limiting Exposures: Supervise construction operations to ensure that no part of the construction, completed or in progress, is subject to harmful, dangerous, damaging, or otherwise deleterious exposure during the construction period.
3.7 STARTING AND ADJUSTING
A. Start equipment and operating components to confirm proper operation. Remove malfunctioning units, replace with new units, and retest.
B. Adjust equipment for proper operation. Adjust operating components for proper operation without binding.
C. Test each piece of equipment to verify proper operation. Test and adjust controls and safeties.
Replace damaged and malfunctioning controls and equipment.
D. Manufacturer's Field Service: Comply with qualification requirements in Section 014000 "Quality Requirements."
3.8 PROTECTION OF INSTALLED CONSTRUCTION
A. Provide final protection and maintain conditions that ensure installed Work is without damage or deterioration at time of Substantial Completion.
B. Protection of Existing Items: Provide protection and ensure that existing items to remain undisturbed by construction are maintained in condition that existed at commencement of the Work.
C. Comply with manufacturer's written instructions for temperature and relative humidity.
3.9 CORRECTION OF THE WORK
A. Repair or remove and replace damaged, defective, or nonconforming Work. Restore damaged substrates and finishes.
1. Repairing includes replacing defective parts, refinishing damaged surfaces, touching up with matching materials, and properly adjusting operating equipment.
B. Repair Work previously completed and subsequently damaged during construction period.
Repair to like-new condition.
C. Restore permanent facilities used during construction to their specified condition. 183
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXECUTION 017300 - 9
D. Remove and replace damaged surfaces that are exposed to view if surfaces cannot be repaired without visible evidence of repair.
E. Repair components that do not operate properly. Remove and replace operating components that cannot be repaired.
F. Remove and replace chipped, scratched, and broken glass or reflective surfaces.
END OF SECTION 017300
184
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 017419 - 1
SECTION 017419 - CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL PART 1 - GENERAL
1.1 SUMMARY
A. Section includes administrative and procedural requirements for the following:
1. Salvaging nonhazardous demolition and construction waste.
2. Recycling nonhazardous demolition and construction waste.
3. Disposing of nonhazardous demolition and construction waste.
1.2 DEFINITIONS
A. Construction Waste: Building, structure, and site improvement materials and other solid waste resulting from construction, remodeling, renovation, or repair operations. Construction waste includes packaging.
B. Demolition Waste: Building, structure, and site improvement materials resulting from demolition operations.
C. Disposal: Removal of demolition or construction waste and subsequent salvage, sale, recycling, or deposit in landfill, incinerator acceptable to authorities having jurisdiction, or designated spoil areas on Owner’s property.
D. Recycle: Recovery of demolition or construction waste for subsequent processing in preparation for reuse.
E. Salvage: Recovery of demolition or construction waste and subsequent sale or reuse in another facility.
F. Salvage and Reuse: Recovery of demolition or construction waste and subsequent incorporation into the Work.
1.3 MATERIALS OWNERSHIP
A. Unless otherwise indicated, demolition and construction waste becomes property of Contractor.
B. Historic items, relics, antiques, and similar objects including, but not limited to, cornerstones and their contents, commemorative plaques and tablets, and other items of interest or value to Owner that may be uncovered during demolition remain the property of Owner.
1. Carefully salvage in a manner to prevent damage and promptly return to Owner. 185
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 017419 - 2
1.4 ACTION SUBMITTALS
A. Waste Management Plan: Submit plan within 30 days of date established for commencement of the Work.
1.5 INFORMATIONAL SUBMITTALS
A. Waste Reduction Progress Reports: Concurrent with each Application for Payment, submit report. Use Form CWM-7 for construction waste and Form CWM-8 for demolition waste.
Include the following information:
1. Material category.
2. Generation point of waste.
3. Total quantity of waste in tons (tonnes).
4. Quantity of waste salvaged, both estimated and actual in tons (tonnes).
5. Quantity of waste recycled, both estimated and actual in tons (tonnes).
6. Total quantity of waste recovered (salvaged plus recycled) in tons (tonnes).
7. Total quantity of waste recovered (salvaged plus recycled) as a percentage of total waste.
B. Waste Reduction Calculations: Before request for Substantial Completion, submit calculated end-of-Project rates for salvage, recycling, and disposal as a percentage of total waste generated by the Work.
C. Records of Donations: Indicate receipt and acceptance of salvageable waste donated to individuals and organizations. Indicate whether organization is tax exempt.
D. Records of Sales: Indicate receipt and acceptance of salvageable waste sold to individuals and organizations. Indicate whether organization is tax exempt.
E. Recycling and Processing Facility Records: Indicate receipt and acceptance of recyclable waste by recycling and processing facilities licensed to accept them. Include manifests, weight tickets, receipts, and invoices.
F. Landfill and Incinerator Disposal Records: Indicate receipt and acceptance of waste by landfills and incinerator facilities licensed to accept them. Include manifests, weight tickets, receipts, and invoices.
G. Qualification Data: For waste management coordinator and refrigerant recovery technician.
H. Statement of Refrigerant Recovery: Signed by refrigerant recovery technician responsible for recovering refrigerant, stating that all refrigerant that was present was recovered and that recovery was performed according to EPA regulations. Include name and address of technician and date refrigerant was recovered.
I. Refrigerant Recovery: Comply with requirements in Section 024119 "Selective Demolition" for refrigerant recovery submittals.
186
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 017419 - 3
1.6 QUALITY ASSURANCE
A. Waste Management Coordinator Qualifications: Experienced firm, or individual employed and assigned by General Contractor, with a record of successful waste management coordination of projects with similar requirements. Superintendent may not serve as Waste Management Coordinator.
B. Refrigerant Recovery Technician Qualifications: Universal certified by EPA-approved certification program.
C. Refrigerant Recovery Technician Qualifications: Comply with requirements in Section 024119 "Selective Demolition."
D. Regulatory Requirements: Comply with transportation and disposal regulations of authorities having jurisdiction.
1.7 WASTE MANAGEMENT PLAN
A. General: Develop a waste management plan according to requirements in this Section. Plan shall consist of waste identification, waste reduction work plan, and cost/revenue analysis. Distinguish between demolition and construction waste. Indicate quantities by weight or volume, but use same units of measure throughout waste management plan.
B. Waste Identification: Indicate anticipated types and quantities of demolition and construction waste generated by the Work. Use Form CWM-1 for construction waste and Form CWM-2 for demolition waste Include estimated quantities and assumptions for estimates.
C. Waste Reduction Work Plan: List each type of waste and whether it will be salvaged, recycled, or disposed of in landfill or incinerator. Use Form CWM-3 for construction waste and Form CWM-4 for demolition waste. Include points of waste generation, total quantity of each type of waste, quantity for each means of recovery, and handling and transportation procedures.
1. Salvaged Materials for Reuse: For materials that will be salvaged and reused in this Project, describe methods for preparing salvaged materials before incorporation into the Work in compliance with Section 024119 "Selective Demolition."
2. Salvaged Materials for Sale: For materials that will be sold to individuals and organizations, include list of their names, addresses, and telephone numbers.
3. Salvaged Materials for Donation: For materials that will be donated to individuals and organizations, include list of their names, addresses, and telephone numbers.
4. Recycled Materials: Include list of local receivers and processors and type of recycled materials each will accept. Include names, addresses, and telephone numbers.
5. Disposed Materials: Indicate how and where materials will be disposed of. Include name, address, and telephone number of each landfill and incinerator facility.
6. Handling and Transportation Procedures: Include method that will be used for separating recyclable waste including sizes of containers, container labeling, and designated location where materials separation will be performed.
D. Cost/Revenue Analysis: Indicate total cost of waste disposal as if there were no waste management plan and net additional cost or net savings resulting from implementing waste 187
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 017419 - 4
management plan. Use Form CWM-5 for construction waste and Form CWM-6 for demolition waste. Include the following:
1. Total quantity of waste.
2. Estimated cost of disposal (cost per unit). Include transportation and tipping fees and cost of collection containers and handling for each type of waste.
3. Total cost of disposal (with no waste management).
4. Revenue from salvaged materials.
5. Revenue from recycled materials.
6. Savings in transportation and tipping fees by donating materials.
7. Savings in transportation and tipping fees that are avoided.
8. Handling and transportation costs. Include cost of collection containers for each type of waste.
9. Net additional cost or net savings from waste management plan.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. General: Achieve end-of-Project rates for salvage/recycling of 50 percent by weight of total nonhazardous solid waste generated by the Work. Practice efficient waste management in the use of materials in the course of the Work. Use all reasonable means to divert construction and demolition waste from landfills and incinerators. Facilitate recycling and salvage of materials, including the following:
1. Demolition Waste:
a. Concrete.
b. Concrete reinforcing steel.
c. Brick.
d. Concrete masonry units.
e. Wood studs.
f. Wood joists.
g. Plywood and oriented strand board.
h. Wood paneling.
i. Wood trim.
j. Miscellaneous steel.
k. Rough hardware.
l. Roofing.
m. Insulation.
n. Metal studs.
o. Gypsum board.
p. Acoustical tile and panels.
q. Equipment.
r. Plumbing fixtures.
s. Piping.
t. Supports and hangers.
u. Valves.
v. Mechanical equipment.
w. Refrigerants.
188
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 017419 - 5
x. Electrical conduit.
y. Copper wiring.
z. Electrical devices.
2. Construction Waste:
a. Masonry and CMU.
b. Lumber.
c. Wood sheet materials.
d. Wood trim.
e. Metals.
f. Insulation.
g. Gypsum board.
h. Piping.
i. Electrical conduit.
j. Packaging: Regardless of salvage/recycle goal indicated in "General" Paragraph above, salvage or recycle 100 percent of the following uncontaminated packaging materials:
1) Paper.
2) Cardboard.
3) Boxes.
4) Plastic sheet and film.
5) Polystyrene packaging.
6) Wood crates.
7) Wood pallets.
8) Plastic pails.
k. Construction Office Waste: Regardless of salvage/recycle goal indicated in "General" Paragraph above, salvage or recycle 100 percent of the following construction office waste materials:
1) Paper.
2) Aluminum cans.
3) Glass containers.
PART 3 - EXECUTION
3.1 PLAN IMPLEMENTATION
A. General: Implement approved waste management plan. Provide handling, containers, storage, signage, transportation, and other items as required to implement waste management plan during the entire duration of the Contract.
B. Waste Management Coordinator: Engage a waste management coordinator to be responsible for implementing, monitoring, and reporting status of waste management work plan. Coordinator shall be present at Project site full time for duration of Project. 189
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 017419 - 6
C. Training: Train workers, subcontractors, and suppliers on proper waste management procedures, as appropriate for the Work.
1. Distribute waste management plan to everyone concerned within three days of submittal return.
2. Distribute waste management plan to entities when they first begin work on-site. Review plan procedures and locations established for salvage, recycling, and disposal.
D. Site Access and Temporary Controls: Conduct waste management operations to ensure minimum interference with roads, streets, walks, walkways, and other adjacent occupied and used facilities.
1. Designate and label specific areas on Project site necessary for separating materials that are to be salvaged and recycled.
3.2 SALVAGING DEMOLITION WASTE
A. Comply with requirements in Section 024119 "Selective Demolition" for salvaging demolition waste.
B. Salvaged Items for Reuse in the Work: Salvage items for reuse and handle as follows:
1. Clean salvaged items.
2. Pack or crate items after cleaning. Identify contents of containers with label indicating elements, date of removal, quantity, and location where removed.
3. Store items in a secure area until installation.
4. Protect items from damage during transport and storage.
5. Install salvaged items to comply with installation requirements for new materials and equipment. Provide connections, supports, and miscellaneous materials necessary to make items functional for use indicated.
C. Salvaged Items for Sale and Donation: Permitted on Project site.
D. Salvaged Items for Owner's Use: Salvage items for Owner's use and handle as follows:
1. Clean salvaged items.
2. Pack or crate items after cleaning. Identify contents of containers with label indicating elements, date of removal, quantity, and location where removed.
3. Store items in a secure area until delivery to Owner.
4. Transport items to Owner's storage area designated by Owner.
5. Protect items from damage during transport and storage.
E. Doors and Hardware: Brace open end of door frames. Except for removing door closers, leave door hardware attached to doors.
F. Equipment: Drain tanks, piping, and fixtures. Seal openings with caps or plugs. Protect equipment from exposure to weather.
G. Plumbing Fixtures: Separate by type and size.
190
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 017419 - 7
H. Lighting Fixtures: Separate lamps by type and protect from breakage.
I. Electrical Devices: Separate switches, receptacles, switchgear, transformers, meters, panelboards, circuit breakers, and other devices by type.
3.3 RECYCLING DEMOLITION AND CONSTRUCTION WASTE, GENERAL A. General: Recycle paper and beverage containers used by on-site workers.
B. Recycling Incentives: Revenues, savings, rebates, tax credits, and other incentives received for recycling waste materials shall accrue to Contractor.
C. Preparation of Waste: Prepare and maintain recyclable waste materials according to recycling or reuse facility requirements. Maintain materials free of dirt, adhesives, solvents, petroleum contamination, and other substances deleterious to the recycling process.
D. Procedures: Separate recyclable waste from other waste materials, trash, and debris. Separate recyclable waste by type at Project site to the maximum extent practical according to approved construction waste management plan.
1. Provide appropriately marked containers or bins for controlling recyclable waste until removed from Project site. Include list of acceptable and unacceptable materials at each container and bin.
a. Inspect containers and bins for contamination and remove contaminated materials if found.
2. Stockpile processed materials on-site without intermixing with other materials. Place, grade, and shape stockpiles to drain surface water. Cover to prevent windblown dust.
3. Stockpile materials away from construction area. Do not store within drip line of remaining trees.
4. Store components off the ground and protect from the weather.
5. Remove recyclable waste from Owner's property and transport to recycling receiver or processor as often as required to prevent overfilling bins.
3.4 RECYCLING DEMOLITION WASTE
A. Concrete: Remove reinforcement and other metals from concrete and sort with other metals.
1. Pulverize concrete to maximum 4-inch (100-mm) size.
B. Masonry: Remove metal reinforcement, anchors, and ties from masonry and sort with other metals.
1. Pulverize masonry to maximum 4-inch (100-mm) size.
2. Clean and stack undamaged, whole masonry units on wood pallets. 191
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 017419 - 8
C. Wood Materials: Sort and stack members according to size, type, and length. Separate lumber, engineered wood products, panel products, and treated wood materials.
D. Metals: Separate metals by type.
1. Structural Steel: Stack members according to size, type of member, and length.
2. Remove and dispose of bolts, nuts, washers, and other rough hardware.
E. Asphalt Shingle Roofing: Separate organic and glass-fiber asphalt shingles and felts. Remove and dispose of nails, staples, and accessories.
F. Gypsum Board: Stack large clean pieces on wood pallets or in container and store in a dry location. Remove edge trim and sort with other metals. Remove and dispose of fasteners.
G. Acoustical Ceiling Panels and Tile: Stack large clean pieces on wood pallets and store in a dry location.
H. Metal Suspension System: Separate metal members, including trim and other metals from acoustical panels and tile, and sort with other metals.
I. Piping: Reduce piping to straight lengths and store by material and size. Separate supports, hangers, valves, sprinklers, and other components by material and size.
J. Conduit: Reduce conduit to straight lengths and store by material and size.
K. Lamps: Separate lamps by type and store according to requirements in 40 CFR 273.
3.5 RECYCLING CONSTRUCTION WASTE
A. Packaging:
1. Cardboard and Boxes: Break down packaging into flat sheets. Bundle and store in a dry location.
2. Polystyrene Packaging: Separate and bag materials.
3. Pallets: As much as possible, require deliveries using pallets to remove pallets from Project site. For pallets that remain on-site, break down pallets into component wood pieces and comply with requirements for recycling wood.
4. Crates: Break down crates into component wood pieces and comply with requirements for recycling wood.
3.6 DISPOSAL OF WASTE
A. General: Except for items or materials to be salvaged or recycled, remove waste materials from Project site and legally dispose of them in a landfill or incinerator acceptable to authorities having jurisdiction.
1. Except as otherwise specified, do not allow waste materials that are to be disposed of accumulate on-site.
192
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CONSTRUCTION WASTE MANAGEMENT AND DISPOSAL 017419 - 9
2. Remove and transport debris in a manner that will prevent spillage on adjacent surfaces and areas.
END OF SECTION 017419
193
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CLOSEOUT PROCEDURES 017700 - 1
SECTION 017700 - CLOSEOUT PROCEDURES
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes administrative and procedural requirements for Contract closeout, including, but not limited to, the following:
1. Substantial Completion procedures.
2. Final Completion procedures.
3. List of incomplete items.
4. Submittal of Project warranties.
5. Final cleaning.
B. Related Requirements:
1. Section 012900 "Payment Procedures" for requirements for Applications for Payment for Substantial Completion and Final Completion.
2. Section 017823 "Operation and Maintenance Data" for additional operation and maintenance manual requirements.
3. Section 017839 "Project Record Documents" for submitting Record Drawings, Record Specifications, and Record Product Data.
4. Section 017900 "Demonstration and Training" for requirements to train Owner's maintenance personnel to adjust, operate, and maintain products, equipment, and systems.
1.2 DEFINITIONS
A. List of Incomplete Items: Contractor-prepared list of items to be completed or corrected, prepared for the Engineer's use prior to Engineer's inspection, to determine if the Work is substantially complete.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of cleaning agent.
B. Contractor's List of Incomplete Items: Initial submittal at Substantial Completion.
C. Certified List of Incomplete Items: Final submittal at Final Completion.
1.4 CLOSEOUT SUBMITTALS
A. Certificates of Release: From authorities having jurisdiction.
B. Certificate of Insurance: For continuing coverage.
194
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CLOSEOUT PROCEDURES 017700 - 2
C. Field Report: For pest-control inspection.
1.5 MAINTENANCE MATERIAL SUBMITTALS
A. Schedule of Maintenance Material Items: For maintenance material submittal items required by other Sections.
1.6 SUBSTANTIAL COMPLETION PROCEDURES
A. Contractor's List of Incomplete Items: Prepare and submit a list of items to be completed and corrected (Contractor's "punch list"), indicating the value of each item on the list and reasons why the Work is incomplete.
B. Submittals Prior to Substantial Completion: Complete the following a minimum of 10 days prior to requesting inspection for determining date of Substantial Completion. List items below that are incomplete at time of request.
1. Certificates of Release: Obtain and submit releases from authorities having jurisdiction, permitting Owner unrestricted use of the Work and access to services and utilities.
Include occupancy permits, operating certificates, and similar releases.
2. Submit closeout submittals specified in other Division 01 Sections, including Project Record Documents, operation and maintenance manuals, damage or settlement surveys, property surveys, and similar final record information.
3. Submit closeout submittals specified in individual Sections, including specific warranties, workmanship bonds, maintenance service agreements, final certifications, and similar documents.
4. Submit maintenance material submittals specified in individual Sections, including tools, spare parts, extra materials, and similar items, and deliver to location designated by Engineer. Label with manufacturer's name and model number. a. Schedule of Maintenance Material Items: Prepare and submit schedule of maintenance material submittal items, including name and quantity of each item and name and number of related Specification Section. Obtain Owner's signature for receipt of submittals.
5. Submit testing, adjusting, and balancing records.
6. Submit sustainable design submittals not previously submitted.
7. Submit changeover information related to Owner's occupancy, use, operation, and maintenance.
C. Procedures Prior to Substantial Completion: Complete the following a minimum of 10 days prior to requesting inspection for determining date of Substantial Completion. List items below that are incomplete at time of request.
1. Advise Owner of pending insurance changeover requirements.
2. Make final changeover of permanent locks and deliver keys to Owner. Advise Owner's personnel of changeover in security provisions.
3. Complete startup and testing of systems and equipment.
4. Perform preventive maintenance on equipment used prior to Substantial Completion. 195
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CLOSEOUT PROCEDURES 017700 - 3
5. Instruct Owner's personnel in operation, adjustment, and maintenance of products, equipment, and systems. Submit demonstration and training video recordings specified in Section 017900 "Demonstration and Training."
6. Advise Owner of changeover in utility services.
7. Participate with Owner in conducting inspection and walkthrough with local emergency responders.
8. Terminate and remove temporary facilities from Project site, along with mockups, construction tools, and similar elements.
9. Complete final cleaning requirements.
10. Touch up paint and otherwise repair and restore marred exposed finishes to eliminate visual defects.
D. Inspection: Submit a written request for inspection to determine Substantial Completion a minimum of 10 days prior to date the Work will be completed and ready for final inspection and tests. On receipt of request, Engineer will either proceed with inspection or notify Contractor of unfulfilled requirements. Engineer will prepare the Certificate of Substantial Completion after inspection or will notify Contractor of items, either on Contractor's list or additional items identified by Engineer, that must be completed or corrected before certificate will be issued.
1. Request reinspection when the Work identified in previous inspections as incomplete is completed or corrected.
2. Results of completed inspection will form the basis of requirements for Final Completion.
1.7 FINAL COMPLETION PROCEDURES
A. Submittals Prior to Final Completion: Before requesting final inspection for determining Final Completion, complete the following:
1. Submit a final Application for Payment in accordance with Section 012900 "Payment Procedures."
2. Certified List of Incomplete Items: Submit certified copy of Engineer's Substantial Completion inspection list of items to be completed or corrected (punch list), endorsed and dated by Engineer. Certified copy of the list will state that each item has been completed or otherwise resolved for acceptance.
3. Certificate of Insurance: Submit evidence of final, continuing insurance coverage complying with insurance requirements.
4. Submit pest-control final inspection report.
5. Submit Final Completion photographic documentation.
B. Inspection: Submit a written request for final inspection to determine acceptance a minimum of 10 days prior to date the Work will be completed and ready for final inspection and tests. On receipt of request, Engineer will either proceed with inspection or notify Contractor of unfulfilled requirements. Engineer will prepare a final Certificate for Payment after inspection or will notify Contractor of construction that must be completed or corrected before certificate will be issued.
1. Request reinspection when the Work identified in previous inspections as incomplete is completed or corrected.
196
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CLOSEOUT PROCEDURES 017700 - 4
1.8 LIST OF INCOMPLETE ITEMS
A. Organization of List: Include name and identification of each space and area affected by construction operations for incomplete items and items needing correction including, if necessary, areas disturbed by Contractor that are outside the limits of construction.
1. Organize list of spaces in sequential order, listed by room or space number.
2. Organize items applying to each space by major element, including categories for ceilings, individual walls, floors, equipment, and building systems.
3. Include the following information at the top of each page:
a. Project name.
b. Date.
c. Name of Engineer.
d. Name of Contractor.
e. Page number.
4. Submit list of incomplete items in the following format:
a. MS Excel Electronic File: Engineer will return annotated file. b. PDF Electronic File: Engineer will return annotated file.
1.9 SUBMITTAL OF PROJECT WARRANTIES
A. Time of Submittal: Submit written warranties on request of Engineer for designated portions of the Work where warranties are indicated to commence on dates other than date of Substantial Completion, or when delay in submittal of warranties might limit Owner's rights under warranty.
B. Partial Occupancy: Submit properly executed warranties within 15 days of completion of designated portions of the Work that are completed and occupied or used by Owner during construction period by separate agreement with Contractor.
C. Organize warranty documents into an orderly sequence based on the table of contents of Project Manual.
D. Warranty Electronic File: Provide warranties and bonds in PDF format. Assemble complete warranty and bond submittal package into a single electronic PDF file with bookmarks enabling navigation to each item. Provide bookmarked table of contents at beginning of document.
E. Provide additional copies of each warranty to include in operation and maintenance manuals. 197
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CLOSEOUT PROCEDURES 017700 - 5
PART 2 - PRODUCTS
2.1 MATERIALS
A. Cleaning Agents: Use cleaning materials and agents recommended by manufacturer or fabricator of the surface to be cleaned. Do not use cleaning agents that are potentially hazardous to health or property or that might damage finished surfaces.
1. Use cleaning products that comply with Green Seal's GS-37, or if GS-37 is not applicable, use products that comply with the California Code of Regulations maximum allowable VOC levels.
PART 3 - EXECUTION
3.1 FINAL CLEANING
A. General: Perform final cleaning. Conduct cleaning and waste-removal operations to comply with local laws and ordinances and Federal and local environmental and antipollution regulations.
B. Cleaning: Employ experienced workers or professional cleaners for final cleaning. Clean each surface or unit to condition expected in an average commercial building cleaning and maintenance program. Comply with manufacturer's written instructions.
1. Complete the following cleaning operations before requesting inspection for certification of Substantial Completion for entire Project or for a designated portion of Project:
a. Clean Project site of rubbish, waste material, litter, and other foreign substances. b. Sweep paved areas broom clean. Remove petrochemical spills, stains, and other foreign deposits.
c. Rake grounds that are not planted, mulched, or paved to a smooth, even-textured surface.
d. Remove tools, construction equipment, machinery, and surplus material from Project site.
e. Remove snow and ice to provide safe access to building. f. Clean exposed exterior and interior hard-surfaced finishes to a dirt-free condition, free of stains, films, and similar foreign substances. Avoid disturbing natural weathering of exterior surfaces. Restore reflective surfaces to their original condition.
g. Remove debris and surface dust from limited-access spaces, including roofs, plenums, shafts, trenches, equipment vaults, manholes, attics, and similar spaces. h. Clean flooring, removing debris, dirt, and staining; clean in accordance with manufacturer's instructions.
i. Vacuum and mop concrete.
j. Vacuum carpet and similar soft surfaces, removing debris and excess nap; clean in accordance with manufacturer's instructions if visible soil or stains remain. 198
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CLOSEOUT PROCEDURES 017700 - 6
k. Clean transparent materials, including mirrors and glass in doors and windows.
Remove glazing compounds and other noticeable, vision-obscuring materials.
Polish mirrors and glass, taking care not to scratch surfaces. l. Remove labels that are not permanent.
m. Wipe surfaces of mechanical and electrical equipment and similar equipment.
Remove excess lubrication, paint and mortar droppings, and other foreign substances.
n. Clean plumbing fixtures to a sanitary condition, free of stains, including stains resulting from water exposure.
o. Replace disposable air filters and clean permanent air filters. Clean exposed surfaces of diffusers, registers, and grills.
p. Clean ducts, blowers, and coils.
1) Clean HVAC system in compliance with NADCA ACR. Provide written report on completion of cleaning.
q. Clean luminaires, lamps, globes, and reflectors to function with full efficiency. r. Clean strainers.
s. Leave Project clean and ready for occupancy.
C. Pest Control: Comply with pest control requirements in Section 015000 "Temporary Facilities and Controls." Prepare written report.
D. Construction Waste Disposal: Comply with waste-disposal requirements in Section 017419 "Construction Waste Management and Disposal."
3.2 CORRECTION OF THE WORK
A. Complete repair and restoration operations required by "Correction of the Work" Article in Section 017300 "Execution" before requesting inspection for determination of Substantial Completion.
END OF SECTION 017700
199
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
OPERATION AND MAINTENANCE DATA 017823 - 1
SECTION 017823 - OPERATION AND MAINTENANCE DATA
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes administrative and procedural requirements for preparing operation and maintenance manuals, including the following:
1. Operation and maintenance documentation directory manuals.
2. Emergency manuals.
3. Systems and equipment operation manuals.
4. Systems and equipment maintenance manuals.
5. Product maintenance manuals.
B. Related Requirements:
1. Section 013300 "Submittal Procedures" for submitting copies of submittals for operation and maintenance manuals.
1.2 DEFINITIONS
A. System: An organized collection of parts, equipment, or subsystems united by regular interaction.
B. Subsystem: A portion of a system with characteristics similar to a system.
1.3 CLOSEOUT SUBMITTALS
A. Submit operation and maintenance manuals indicated. Provide content for each manual as specified in individual Specification Sections, and as reviewed and approved at the time of Section submittals. Submit reviewed manual content formatted and organized as required by this Section.
1. Engineer will comment on whether content of operation and maintenance submittals is acceptable.
2. Where applicable, clarify and update reviewed manual content to correspond to revisions and field conditions.
B. Format: Submit operation and maintenance manuals in the following format:
1. Submit by email to Engineer of Record. Enable reviewer comments on draft submittals.
C. Final Manual Submittal: Submit each manual in final form prior to requesting inspection for Substantial Completion and at least 15 days before commencing demonstration and training.
Engineer will return copy with comments.
200
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
OPERATION AND MAINTENANCE DATA 017823 - 2
1. Correct or revise each manual to comply with Engineer's comments. Submit copies of each corrected manual within 15 days of receipt of Engineer's comments and prior to commencing demonstration and training.
D. Comply with Section 017700 "Closeout Procedures" for schedule for submitting operation and maintenance documentation.
1.4 FORMAT OF OPERATION AND MAINTENANCE MANUALS
A. Manuals, Electronic Files: Submit manuals in the form of a multiple file composite electronic PDF file for each manual type required.
1. Electronic Files: Use electronic files prepared by manufacturer where available. Where scanning of paper documents is required, configure scanned file for minimum readable file size.
2. File Names and Bookmarks: Bookmark individual documents based on file names. Name document files to correspond to system, subsystem, and equipment names used in manual directory and table of contents. Group documents for each system and subsystem into individual composite bookmarked files, then create composite manual, so that resulting bookmarks reflect the system, subsystem, and equipment names in a readily navigated file tree. Configure electronic manual to display bookmark panel on opening file.
B. Manuals, Paper Copy: Submit manuals in the form of hard-copy, bound and labeled volumes.
1. Binders: Heavy-duty, three-ring, vinyl-covered, post-type binders, in thickness necessary to accommodate contents, sized to hold 8-1/2-by-11-inch (215-by-280-mm) paper; with clear plastic sleeve on spine to hold label describing contents and with pockets inside covers to hold folded oversize sheets.
a. If two or more binders are necessary to accommodate data of a system, organize data in each binder into groupings by subsystem and related components. Crossreference other binders if necessary to provide essential information for proper operation or maintenance of equipment or system.
b. Identify each binder on front and spine, with printed title "OPERATION AND MAINTENANCE MANUAL," Project title or name, and subject matter of contents. Indicate volume number for multiple-volume sets.
2. Dividers: Heavy-paper dividers with plastic-covered tabs for each section of the manual.
Mark each tab to indicate contents. Include typed list of products and major components of equipment included in the section on each divider, cross-referenced to Specification Section number and title of Project Manual.
3. Protective Plastic Sleeves: Transparent plastic sleeves designed to enclose diagnostic software storage media for computerized electronic equipment. Enclose title pages and directories in clear plastic sleeves.
4. Drawings: Attach reinforced, punched binder tabs on drawings and bind with text. a. If oversize drawings are necessary, fold drawings to same size as text pages and use as foldouts.
b. If drawings are too large to be used as foldouts, fold and place drawings in labeled envelopes and bind envelopes in rear of manual. At appropriate locations in 201
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
OPERATION AND MAINTENANCE DATA 017823 - 3
manual, insert typewritten pages indicating drawing titles, descriptions of contents, and drawing locations.
1.5 REQUIREMENTS FOR EMERGENCY, OPERATION, AND MAINTENANCE MANUALS A. Organization of Manuals: Unless otherwise indicated, organize each manual into a separate section for each system and subsystem, and a separate section for each piece of equipment not part of a system. Each manual shall contain the following materials, in the order listed:
1. Title page.
2. Table of contents.
3. Manual contents.
B. Title Page: Include the following information:
1. Subject matter included in manual.
2. Name and address of Project.
3. Name and address of Owner.
4. Date of submittal.
5. Name and contact information for Contractor.
6. Name and contact information for Construction Manager.
7. Name and contact information for Engineer.
8. Name and contact information for Commissioning Authority.
9. Names and contact information for major consultants to the Engineer that designed the systems contained in the manuals.
10. Cross-reference to related systems in other operation and maintenance manuals.
C. Table of Contents: List each product included in manual, identified by product name, indexed to the content of the volume, and cross-referenced to Specification Section number in Project Manual.
1. If operation or maintenance documentation requires more than one volume to accommodate data, include comprehensive table of contents for all volumes in each volume of the set.
D. Manual Contents: Organize into sets of manageable size. Arrange contents alphabetically by system, subsystem, and equipment. If possible, assemble instructions for subsystems, equipment, and components of one system into a single binder.
E. Identification: In the documentation directory and in each operation and maintenance manual, identify each system, subsystem, and piece of equipment with same designation used in the Contract Documents. If no designation exists, assign a designation according to ASHRAE Guideline 4, "Preparation of Operating and Maintenance Documentation for Building Systems."
202
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
OPERATION AND MAINTENANCE DATA 017823 - 4
1.6 EMERGENCY MANUALS
A. Emergency Manual: Assemble a complete set of emergency information indicating procedures for use by emergency personnel and by Owner's operating personnel for types of emergencies indicated.
B. Content: Organize manual into a separate section for each of the following:
1. Type of emergency.
2. Emergency instructions.
3. Emergency procedures.
C. Type of Emergency: Where applicable for each type of emergency indicated below, include instructions and procedures for each system, subsystem, piece of equipment, and component:
1. Fire.
2. Flood.
3. Gas leak.
4. Water leak.
5. Power failure.
6. Water outage.
7. System, subsystem, or equipment failure.
8. Chemical release or spill.
D. Emergency Instructions: Describe and explain warnings, trouble indications, error messages, and similar codes and signals. Include responsibilities of Owner's operating personnel for notification of Installer, supplier, and manufacturer to maintain warranties.
E. Emergency Procedures: Include the following, as applicable:
1. Instructions on stopping.
2. Shutdown instructions for each type of emergency.
3. Operating instructions for conditions outside normal operating limits.
4. Required sequences for electric or electronic systems.
5. Special operating instructions and procedures.
1.7 SYSTEMS AND EQUIPMENT OPERATION MANUALS
A. Systems and Equipment Operation Manual: Assemble a complete set of data indicating operation of each system, subsystem, and piece of equipment not part of a system. Include information required for daily operation and management, operating standards, and routine and special operating procedures.
1. Engage a factory-authorized service representative to assemble and prepare information for each system, subsystem, and piece of equipment not part of a system.
2. Prepare a separate manual for each system and subsystem, in the form of an instructional manual for use by Owner's operating personnel.
B. Content: In addition to requirements in this Section, include operation data required in individual Specification Sections and the following information:
203
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
OPERATION AND MAINTENANCE DATA 017823 - 5
1. System, subsystem, and equipment descriptions. Use designations for systems and equipment indicated on Contract Documents.
2. Performance and design criteria if Contractor has delegated design responsibility.
3. Operating standards.
4. Operating procedures.
5. Operating logs.
6. Wiring diagrams.
7. Control diagrams.
8. Piped system diagrams.
9. Precautions against improper use.
10. License requirements including inspection and renewal dates.
C. Descriptions: Include the following:
1. Product name and model number. Use designations for products indicated on Contract Documents.
2. Manufacturer's name.
3. Equipment identification with serial number of each component.
4. Equipment function.
5. Operating characteristics.
6. Limiting conditions.
7. Performance curves.
8. Engineering data and tests.
9. Complete nomenclature and number of replacement parts.
D. Operating Procedures: Include the following, as applicable:
1. Startup procedures.
2. Equipment or system break-in procedures.
3. Routine and normal operating instructions.
4. Regulation and control procedures.
5. Instructions on stopping.
6. Normal shutdown instructions.
7. Seasonal and weekend operating instructions.
8. Required sequences for electric or electronic systems.
9. Special operating instructions and procedures.
E. Systems and Equipment Controls: Describe the sequence of operation, and diagram controls as installed.
F. Piped Systems: Diagram piping as installed and identify color coding where required for identification.
1.8 SYSTEMS AND EQUIPMENT MAINTENANCE MANUALS
A. Systems and Equipment Maintenance Manuals: Assemble a complete set of data indicating maintenance of each system, subsystem, and piece of equipment not part of a system. Include manufacturers' maintenance documentation, preventive maintenance procedures and frequency, repair procedures, wiring and systems diagrams, lists of spare parts, and warranty information. 204
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
OPERATION AND MAINTENANCE DATA 017823 - 6
1. Engage a factory-authorized service representative to assemble and prepare information for each system, subsystem, and piece of equipment not part of a system.
2. Prepare a separate manual for each system and subsystem, in the form of an instructional manual for use by Owner's operating personnel.
B. Content: For each system, subsystem, and piece of equipment not part of a system, include source information, manufacturers' maintenance documentation, maintenance procedures, maintenance and service schedules, spare parts list and source information, maintenance service contracts, and warranties and bonds as described below.
C. Source Information: List each system, subsystem, and piece of equipment included in manual, identified by product name and arranged to match manual's table of contents. For each product, list name, address, and telephone number of Installer or supplier and maintenance service agent, and cross-reference Specification Section number and title in Project Manual and drawing or schedule designation or identifier where applicable.
D. Manufacturers' Maintenance Documentation: Include the following information for each component part or piece of equipment:
1. Standard maintenance instructions and bulletins; include only sheets pertinent to product or component installed. Mark each sheet to identify each product or component incorporated into the Work. If data include more than one item in a tabular format, identify each item using appropriate references from the Contract Documents. Identify data applicable to the Work and delete references to information not applicable. a. Prepare supplementary text if manufacturers' standard printed data are not available and where the information is necessary for proper operation and maintenance of equipment or systems.
2. Drawings, diagrams, and instructions required for maintenance, including disassembly and component removal, replacement, and assembly.
3. Identification and nomenclature of parts and components.
4. List of items recommended to be stocked as spare parts.
E. Maintenance Procedures: Include the following information and items that detail essential maintenance procedures:
1. Test and inspection instructions.
2. Troubleshooting guide.
3. Precautions against improper maintenance.
4. Disassembly; component removal, repair, and replacement; and reassembly instructions.
5. Aligning, adjusting, and checking instructions.
6. Demonstration and training video recording, if available.
F. Maintenance and Service Schedules: Include service and lubrication requirements, list of required lubricants for equipment, and separate schedules for preventive and routine maintenance and service with standard time allotment.
1. Scheduled Maintenance and Service: Tabulate actions for daily, weekly, monthly, quarterly, semiannual, and annual frequencies.
205
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
OPERATION AND MAINTENANCE DATA 017823 - 7
2. Maintenance and Service Record: Include manufacturers' forms for recording maintenance.
G. Spare Parts List and Source Information: Include lists of replacement and repair parts, with parts identified and cross-referenced to manufacturers' maintenance documentation and local sources of maintenance materials and related services.
H. Maintenance Service Contracts: Include copies of maintenance agreements with name and telephone number of service agent.
I. Warranties and Bonds: Include copies of warranties and bonds and lists of circumstances and conditions that would affect validity of warranties or bonds.
1. Include procedures to follow and required notifications for warranty claims.
J. Drawings: Prepare drawings supplementing manufacturers' printed data to illustrate the relationship of component parts of equipment and systems and to illustrate control sequence and flow diagrams. Coordinate these drawings with information contained in record Drawings to ensure correct illustration of completed installation.
1. Do not use original project record documents as part of maintenance manuals.
1.9 PRODUCT MAINTENANCE MANUALS
A. Product Maintenance Manual: Assemble a complete set of maintenance data indicating care and maintenance of each product, material, and finish incorporated into the Work.
B. Content: Organize manual into a separate section for each product, material, and finish. Include source information, product information, maintenance procedures, repair materials and sources, and warranties and bonds, as described below.
C. Source Information: List each product included in manual, identified by product name and arranged to match manual's table of contents. For each product, list name, address, and telephone number of Installer or supplier and maintenance service agent, and cross-reference Specification Section number and title in Project Manual and drawing or schedule designation or identifier where applicable.
D. Product Information: Include the following, as applicable:
1. Product name and model number.
2. Manufacturer's name.
3. Color, pattern, and texture.
4. Material and chemical composition.
5. Reordering information for specially manufactured products.
E. Maintenance Procedures: Include manufacturer's written recommendations and the following:
1. Inspection procedures.
2. Types of cleaning agents to be used and methods of cleaning.
3. List of cleaning agents and methods of cleaning detrimental to product. 206
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
OPERATION AND MAINTENANCE DATA 017823 - 8
4. Schedule for routine cleaning and maintenance.
5. Repair instructions.
F. Repair Materials and Sources: Include lists of materials and local sources of materials and related services.
G. Warranties and Bonds: Include copies of warranties and bonds and lists of circumstances and conditions that would affect validity of warranties or bonds.
1. Include procedures to follow and required notifications for warranty claims.
PART 2 - PRODUCTS (Not Used)
PART 3 - EXECUTION (Not Used)
END OF SECTION 017823
207
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
PROJECT RECORD DOCUMENTS 017839 - 1
SECTION 017839 - PROJECT RECORD DOCUMENTS
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section includes administrative and procedural requirements for Project Record Documents, including the following:
1. Record Drawings.
2. Record specifications.
3. Record Product Data.
4. Miscellaneous record submittals.
B. Related Requirements:
1. Section 017300 "Execution" for final property survey.
2. Section 017700 "Closeout Procedures" for general closeout procedures.
3. Section 017823 "Operation and Maintenance Data" for operation and maintenance manual requirements.
1.3 CLOSEOUT SUBMITTALS
A. Record Drawings: Comply with the following:
1. Number of Copies: Submit one set(s) of marked-up record prints.
2. Number of Copies: Submit copies of Record Drawings as follows:
a. Initial Submittal:
1) Submit PDF electronic files of scanned record prints and one set(s) of file prints.
b. Final Submittal:
1) Submit PDF electronic files of scanned Record Prints and three set(s) of file prints.
B. Record Specifications: Submit annotated PDF electronic files of Project's Specifications, including addenda and Contract modifications.
C. Record Product Data: Submit annotated PDF electronic files and directories of each submittal.
1. Where record Product Data are required as part of operation and maintenance manuals, submit duplicate marked-up Product Data as a component of manual. 208
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
PROJECT RECORD DOCUMENTS 017839 - 2
1.4 RECORD DRAWINGS
A. Record Prints: Maintain one set of marked-up paper copies of the Contract Drawings and Shop Drawings, incorporating new and revised drawings as modifications are issued.
1. Preparation: Mark record prints to show the actual installation, where installation varies from that shown originally. Require individual or entity who obtained record data, whether individual or entity is Installer, subcontractor, or similar entity, to provide information for preparation of corresponding marked-up record prints. a. Give particular attention to information on concealed elements that would be difficult to identify or measure and record later.
b. Accurately record information in an acceptable drawing technique. c. Record data as soon as possible after obtaining it.
d. Record and check the markup before enclosing concealed installations. e. Cross-reference record prints to corresponding photographic documentation.
2. Content: Types of items requiring marking include, but are not limited to, the following:
a. Dimensional changes to Drawings.
b. Revisions to details shown on Drawings.
c. Depths of foundations.
d. Locations and depths of underground utilities.
e. Revisions to routing of piping and conduits.
f. Revisions to electrical circuitry.
g. Actual equipment locations.
h. Duct size and routing.
i. Locations of concealed internal utilities.
j. Changes made by Change Order or Construction Change Directive. k. Changes made following Engineer's written orders.
l. Details not on the original Contract Drawings.
m. Field records for variable and concealed conditions. n. Record information on the Work that is shown only schematically.
3. Mark the Contract Drawings and Shop Drawings completely and accurately. Use personnel proficient at recording graphic information in production of marked-up record prints.
4. Mark record prints with erasable, red-colored pencil. Use other colors to distinguish between changes for different categories of the Work at same location.
5. Mark important additional information that was either shown schematically or omitted from original Drawings.
6. Note Construction Change Directive numbers, alternate numbers, Change Order numbers, and similar identification, where applicable.
B. Record Digital Data Files: Immediately before inspection for Certificate of Substantial Completion, review marked-up record prints with Engineer. When authorized, prepare a full set of corrected digital data files of the Contract Drawings, as follows:
1. Format: Same digital data software program, version, and operating system as for the original Contract Drawings.
2. Format: DWG.
209
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
PROJECT RECORD DOCUMENTS 017839 - 3
3. Format: Annotated PDF electronic file.
4. Incorporate changes and additional information previously marked on record prints.
Delete, redraw, and add details and notations where applicable.
5. Refer instances of uncertainty to Engineer for resolution.
6. Engineer will furnish Contractor with one set of digital data files of the Contract Drawings for use in recording information.
a. See Section 013100 "Project Management and Coordination" for requirements related to use of Engineer's digital data files.
b. Engineer will provide data file layer information. Record markups in separate layers.
C. Format: Identify and date each Record Drawing; include the designation "PROJECT RECORD DRAWING" in a prominent location.
1. Record Prints: Organize record prints into manageable sets. Bind each set with durable paper cover sheets. Include identification on cover sheets.
2. Format: Annotated PDF electronic file.
3. Record Digital Data Files: Organize digital data information into separate electronic files that correspond to each sheet of the Contract Drawings. Name each file with the sheet identification. Include identification in each digital data file.
4. Identification: As follows:
a. Project name.
b. Date.
c. Designation "PROJECT RECORD DRAWINGS."
d. Name of Engineer.
e. Name of Contractor.
1.5 RECORD SPECIFICATIONS
A. Preparation: Mark Specifications to indicate the actual product installation, where installation varies from that indicated in Specifications, addenda, and Contract modifications.
1. Give particular attention to information on concealed products and installations that cannot be readily identified and recorded later.
B. Format: Submit record specifications as annotated PDF electronic file.
1.6 RECORD PRODUCT DATA
A. Recording: Maintain one copy of each submittal during the construction period for Project Record Document purposes. Post changes and revisions to Project Record Documents as they occur; do not wait until end of Project.
B. Preparation: Mark Product Data to indicate the actual product installation where installation varies substantially from that indicated in Product Data submittal. 210
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
PROJECT RECORD DOCUMENTS 017839 - 4
1. Give particular attention to information on concealed products and installations that cannot be readily identified and recorded later.
2. Include significant changes in the product delivered to Project site and changes in manufacturer's written instructions for installation.
3. Note related Change Orders, Record Specifications, and Record Drawings where applicable.
C. Format: Submit Record Product Data as annotated PDF electronic file.
1. Include Record Product Data directory organized by Specification Section number and title, electronically linked to each item of Record Product Data.
1.7 MAINTENANCE OF RECORD DOCUMENTS
A. Maintenance of Record Documents: Store Record Documents in the field office apart from the Contract Documents used for construction. Do not use Project Record Documents for construction purposes. Maintain Record Documents in good order and in a clean, dry, legible condition, protected from deterioration and loss. Provide access to Project Record Documents for Engineer's reference during normal working hours.
PART 2 - PRODUCTS (Not Used)
PART 3 - EXECUTION (Not Used)
END OF SECTION 017839
211
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DEMONSTRATION AND TRAINING 017900 - 1
SECTION 017900 - DEMONSTRATION AND TRAINING
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes administrative and procedural requirements for instructing Owner's personnel, including the following:
1. Instruction in operation and maintenance of systems, subsystems, and equipment.
2. Demonstration and training video recordings.
1.2 INFORMATIONAL SUBMITTALS
A. Instruction Program: Submit outline of instructional program for demonstration and training, including a list of training modules and a schedule of proposed dates, times, length of instruction time, and instructors' names for each training module. Include learning objective and outline for each training module.
1. Indicate proposed training modules using manufacturer-produced demonstration and training video recordings for systems, equipment, and products in lieu of video recording of live instructional module.
B. Qualification Data: For instructor.
C. Attendance Record: For each training module, submit list of participants and length of instruction time.
D. Evaluations: For each participant and for each training module, submit results and documentation of performance-based test.
1.3 CLOSEOUT SUBMITTALS
A. Demonstration and Training Video Recordings: Submit two copies within seven days of end of each training module.
1. Identification: On each copy, provide an applied label with the following information:
a. Name of Project.
b. Name and address of videographer.
c. Name of Architect.
d. Name of Construction Manager.
e. Name of Contractor.
f. Date of video recording.
2. Transcript: Prepared and bound in format matching operation and maintenance manuals.
Mark appropriate identification on front and spine of each binder. Include a cover sheet 212
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DEMONSTRATION AND TRAINING 017900 - 2
with same label information as the corresponding video recording. Include name of Project and date of video recording on each page.
3. Transcript: Prepared in PDF electronic format. Include a cover sheet with same label information as the corresponding video recording and a table of contents with links to corresponding training components. Include name of Project and date of video recording on each page.
4. At completion of training, submit complete training manual(s) for Owner's use prepared in same paper and PDF file format required for operation and maintenance manuals specified in Section 017823 "Operation and Maintenance Data."
1.4 QUALITY ASSURANCE
A. Facilitator Qualifications: A firm or individual experienced in training or educating maintenance personnel in a training program similar in content and extent to that indicated for this Project, and whose work has resulted in training or education with a record of successful learning performance.
B. Instructor Qualifications: A factory-authorized service representative, complying with requirements in Section 014000 "Quality Requirements," experienced in operation and maintenance procedures and training.
C. Videographer Qualifications: A professional videographer who is experienced photographing demonstration and training events similar to those required.
1.5 COORDINATION
A. Coordinate instruction schedule with Owner's operations. Adjust schedule as required to minimize disrupting Owner's operations and to ensure availability of Owner's personnel.
B. Coordinate instructors, including providing notification of dates, times, length of instruction time, and course content.
C. Coordinate content of training modules with content of approved emergency, operation, and maintenance manuals. Do not submit instruction program until operation and maintenance data have been reviewed and approved by Architect.
1.6 INSTRUCTION PROGRAM
A. Program Structure: Develop an instruction program that includes individual training modules for each system and for equipment not part of a system, as required by individual Specification Sections.
B. Training Modules: Develop a learning objective and teaching outline for each module. Include a description of specific skills and knowledge that participant is expected to master. For each module, include instruction for the following as applicable to the system, equipment, or component:
1. Basis of System Design, Operational Requirements, and Criteria: Include the following:
213
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DEMONSTRATION AND TRAINING 017900 - 3
a. System, subsystem, and equipment descriptions.
b. Performance and design criteria if Contractor is delegated design responsibility. c. Operating standards.
d. Regulatory requirements.
e. Equipment function.
f. Operating characteristics.
g. Limiting conditions.
h. Performance curves.
2. Documentation: Review the following items in detail:
a. Emergency manuals.
b. Systems and equipment operation manuals.
c. Systems and equipment maintenance manuals.
d. Product maintenance manuals.
e. Project Record Documents.
f. Identification systems.
g. Warranties and bonds.
h. Maintenance service agreements and similar continuing commitments.
3. Emergencies: Include the following, as applicable:
a. Instructions on meaning of warnings, trouble indications, and error messages. b. Instructions on stopping.
c. Shutdown instructions for each type of emergency.
d. Operating instructions for conditions outside of normal operating limits. e. Sequences for electric or electronic systems.
f. Special operating instructions and procedures.
4. Operations: Include the following, as applicable:
a. Startup procedures.
b. Equipment or system break-in procedures.
c. Routine and normal operating instructions.
d. Regulation and control procedures.
e. Control sequences.
f. Safety procedures.
g. Instructions on stopping.
h. Normal shutdown instructions.
i. Operating procedures for emergencies.
j. Operating procedures for system, subsystem, or equipment failure. k. Seasonal and weekend operating instructions.
l. Required sequences for electric or electronic systems. m. Special operating instructions and procedures.
5. Adjustments: Include the following:
a. Alignments.
b. Checking adjustments.
c. Noise and vibration adjustments.
d. Economy and efficiency adjustments.
214
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DEMONSTRATION AND TRAINING 017900 - 4
6. Troubleshooting: Include the following:
a. Diagnostic instructions.
b. Test and inspection procedures.
7. Maintenance: Include the following:
a. Inspection procedures.
b. Types of cleaning agents to be used and methods of cleaning. c. List of cleaning agents and methods of cleaning detrimental to product. d. Procedures for routine cleaning.
e. Procedures for preventive maintenance.
f. Procedures for routine maintenance.
g. Instruction on use of special tools.
8. Repairs: Include the following:
a. Diagnosis instructions.
b. Repair instructions.
c. Disassembly; component removal, repair, and replacement; and reassembly instructions.
d. Instructions for identifying parts and components.
e. Review of spare parts needed for operation and maintenance.
1.7 PREPARATION
A. Assemble educational materials necessary for instruction, including documentation and training module. Assemble training modules into a training manual organized in coordination with requirements in Section 017823 "Operation and Maintenance Data." B. Set up instructional equipment at instruction location.
1.8 INSTRUCTION
A. Facilitator: Engage a qualified facilitator to prepare instruction program and training modules, to coordinate instructors, and to coordinate between Contractor and Owner for number of participants, instruction times, and location.
B. Engage qualified instructors to instruct Owner's personnel to adjust, operate, and maintain systems, subsystems, and equipment not part of a system.
C. Scheduling: Provide instruction at mutually agreed-on times. For equipment that requires seasonal operation, provide similar instruction at start of each season.
1. Schedule training with Owner, through Construction Manager, with at least seven days' advance notice.
D. Training Location and Reference Material: Conduct training on-site in the completed and fully operational facility using the actual equipment in-place. Conduct training using final operation and maintenance data submittals.
215
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DEMONSTRATION AND TRAINING 017900 - 5
E. Evaluation: At conclusion of each training module, assess and document each participant's mastery of module by use of a written performance-based test.
F. Cleanup: Collect used and leftover educational materials and remove from Project site. Remove instructional equipment. Restore systems and equipment to condition existing before initial training use.
1.9 DEMONSTRATION AND TRAINING VIDEO RECORDINGS
A. Digital Video Recordings: Provide high-resolution, digital video in MPEG format, produced by a digital camera with minimum sensor resolution of 12 megapixels and capable of recording in full HD mode with vibration reduction technology.
1. Submit video recordings by uploading to web-based Project software site.
2. File Hierarchy: Organize folder structure and file locations according to Project Manual table of contents. Provide complete screen-based menu.
3. File Names: Utilize file names based on name of equipment generally described in video segment, as identified in Project specifications.
4. Contractor and Installer Contact File: Using appropriate software, create a file for inclusion on the equipment demonstration and training recording that describes the following for each Contractor involved on the Project, arranged according to Project Manual table of contents:
a. Name of Contractor/Installer.
b. Business address.
c. Business phone number.
d. Point of contact.
e. Email address.
B. Recording: Mount camera on tripod before starting recording, unless otherwise necessary to adequately cover area of demonstration and training. Display continuous running time.
1. Film training session(s) in segments not to exceed 15 minutes. a. Produce segments to present a single significant piece of equipment per segment. b. Organize segments with multiple pieces of equipment to follow order of Project Manual table of contents.
c. Where a training session on a particular piece of equipment exceeds 15 minutes, stop filming and pause training session. Begin training session again upon commencement of new filming segment.
C. Light Levels: Verify light levels are adequate to properly light equipment. Verify equipment markings are clearly visible prior to recording.
1. Furnish additional portable lighting as required.
D. Transcript: Provide a transcript of the narration. Display images and running time captured from videotape opposite the corresponding narration segment. 216
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DEMONSTRATION AND TRAINING 017900 - 6
E. Preproduced Video Recordings: Provide video recordings used as a component of training modules in same format as recordings of live training.
PART 2 - PRODUCTS
PART 3 - EXECUTION
END OF SECTION 017900
217
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SELECTIVE DEMOLITION 024119 - 1
SECTION 024119 - SELECTIVE DEMOLITION
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Demolition and removal of selected portions of building or structure.
2. Demolition and removal of selected site elements.
3. Salvage of existing items to be reused or recycled.
B. Related Requirements:
1. Section 017300 "Execution" for cutting and patching procedures.
2. Section 013516 "Alteration Project Procedures" for general protection and work procedures for alteration projects.
1.2 DEFINITIONS
A. Remove: Detach items from existing construction and dispose of them off-site unless indicated to be salvaged or reinstalled.
B. Remove and Salvage: Detach items from existing construction, in a manner to prevent damage, and deliver to Owner ready for reuse.
C. Remove and Reinstall: Detach items from existing construction, in a manner to prevent damage, prepare for reuse, and reinstall where indicated.
D. Existing to Remain: Leave existing items that are not to be removed and that are not otherwise indicated to be salvaged or reinstalled.
E. Dismantle: To remove by disassembling or detaching an item from a surface, using gentle methods and equipment to prevent damage to the item and surfaces; disposing of items unless indicated to be salvaged or reinstalled.
1.3 MATERIALS OWNERSHIP
A. Unless otherwise indicated, demolition waste becomes property of Contractor.
B. Historic items, relics, antiques, and similar objects including, but not limited to, cornerstones and their contents, commemorative plaques and tablets, and other items of interest or value to Owner that may be uncovered during demolition remain the property of Owner.
1. Carefully salvage in a manner to prevent damage and promptly return to Owner. 218
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SELECTIVE DEMOLITION 024119 - 2
1.4 PREINSTALLATION MEETINGS
A. Predemolition Conference: Conduct conference at Project site.
1. Inspect and discuss condition of construction to be selectively demolished.
2. Review structural load limitations of existing structure.
3. Review and finalize selective demolition schedule and verify availability of materials, demolition personnel, equipment, and facilities needed to make progress and avoid delays.
4. Review requirements of work performed by other trades that rely on substrates exposed by selective demolition operations.
5. Review areas where existing construction is to remain and requires protection.
1.5 INFORMATIONAL SUBMITTALS
A. Qualification Data: For refrigerant recovery technician.
B. Proposed Protection Measures: Submit report, including Drawings, that indicates the measures proposed for protecting individuals and property, for environmental protection, for dust control, and for noise control. Indicate proposed locations and construction of barriers.
C. Schedule of Selective Demolition Activities: Indicate the following:
1. Detailed sequence of selective demolition and removal work, with starting and ending dates for each activity. Ensure Owner's on-site operations are uninterrupted.
2. Interruption of utility services. Indicate how long utility services will be interrupted.
3. Coordination for shutoff, capping, and continuation of utility services.
4. Use of elevator and stairs.
5. Coordination of Owner's continuing occupancy of portions of existing building and of Owner's partial occupancy of completed Work.
D. Predemolition Photographs or Video: Show existing conditions of adjoining construction, including finish surfaces, that might be misconstrued as damage caused by salvage and demolition operations. Submit before Work begins.
E. Statement of Refrigerant Recovery: Signed by refrigerant recovery technician responsible for recovering refrigerant, stating that all refrigerant that was present was recovered and that recovery was performed according to EPA regulations. Include name and address of technician and date refrigerant was recovered.
F. Warranties: Documentation indicating that existing warranties are still in effect after completion of selective demolition.
1.6 CLOSEOUT SUBMITTALS
A. Inventory: Submit a list of items that have been removed and salvaged. 219
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SELECTIVE DEMOLITION 024119 - 3
1.7 QUALITY ASSURANCE
A. Refrigerant Recovery Technician Qualifications: Certified by an EPA-approved certification program.
1.8 FIELD CONDITIONS
A. Owner will occupy portions of building immediately adjacent to selective demolition area.
Conduct selective demolition so Owner's operations will not be disrupted.
B. Conditions existing at time of inspection for bidding purpose will be maintained by Owner as far as practical.
C. Notify Engineer of discrepancies between existing conditions and Drawings before proceeding with selective demolition.
D. Hazardous Materials: Present in buildings and structures to be selectively demolished. A report on the presence of hazardous materials is on file for review and use. Examine report to become aware of locations where hazardous materials are present.
1. Hazardous material remediation is specified elsewhere in the Contract Documents.
2. Do not disturb hazardous materials or items suspected of containing hazardous materials except under procedures specified elsewhere in the Contract Documents.
E. Storage or sale of removed items or materials on-site is not permitted.
F. Utility Service: Maintain existing utilities indicated to remain in service and protect them against damage during selective demolition operations.
1.9 COORDINATION
A. Arrange selective demolition schedule so as not to interfere with Owner's operations.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Regulatory Requirements: Comply with governing EPA notification regulations before beginning selective demolition. Comply with hauling and disposal regulations of authorities having jurisdiction.
B. Standards: Comply with ANSI/ASSP A10.6 and NFPA 241. 220
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SELECTIVE DEMOLITION 024119 - 4
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verify that utilities have been disconnected and capped before starting selective demolition operations.
B. Review Project Record Documents of existing construction or other existing condition and hazardous material information provided by Owner. Owner does not guarantee that existing conditions are same as those indicated in Project Record Documents.
C. Perform an engineering survey of condition of building to determine whether removing any element might result in structural deficiency or unplanned collapse of any portion of structure or adjacent structures during selective building demolition operations.
1. Perform surveys as the Work progresses to detect hazards resulting from selective demolition activities.
D. Verify that hazardous materials have been remediated before proceeding with building demolition operations.
E. Survey of Existing Conditions: Record existing conditions by use of measured drawings and preconstruction photographs or video.
3.2 PREPARATION
A. Refrigerant: Before starting demolition, remove refrigerant from mechanical equipment according to 40 CFR 82 and regulations of authorities having jurisdiction.
3.3 UTILITY SERVICES AND MECHANICAL/ELECTRICAL SYSTEMS
A. Existing Services/Systems to Remain: Maintain services/systems indicated to remain and protect them against damage.
B. Existing Services/Systems to Be Removed, Relocated, or Abandoned: Locate, identify, disconnect, and seal or cap off utility services and mechanical/electrical systems serving areas to be selectively demolished.
1. Arrange to shut off utilities with utility companies.
2. If services/systems are required to be removed, relocated, or abandoned, provide temporary services/systems that bypass area of selective demolition and that maintain continuity of services/systems to other parts of building.
3. Disconnect, demolish, and remove fire-suppression systems, plumbing, and HVAC systems, equipment, and components indicated on Drawings to be removed. a. Piping to Be Removed: Remove portion of piping indicated to be removed and cap or plug remaining piping with same or compatible piping material. 221
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SELECTIVE DEMOLITION 024119 - 5
b. Piping to Be Abandoned in Place: Drain piping and cap or plug piping with same or compatible piping material and leave in place.
c. Equipment to Be Removed: Disconnect and cap services and remove equipment. d. Equipment to Be Removed and Reinstalled: Disconnect and cap services and remove, clean, and store equipment; when appropriate, reinstall, reconnect, and make equipment operational.
e. Equipment to Be Removed and Salvaged: Disconnect and cap services and remove equipment and deliver to Owner.
f. Ducts to Be Removed: Remove portion of ducts indicated to be removed and plug remaining ducts with same or compatible ductwork material. g. Ducts to Be Abandoned in Place: Cap or plug ducts with same or compatible ductwork material and leave in place.
3.4 PROTECTION
A. Temporary Protection: Provide temporary barricades and other protection required to prevent injury to people and damage to adjacent buildings and facilities to remain.
1. Provide protection to ensure safe passage of people around selective demolition area and to and from occupied portions of building.
2. Provide temporary weather protection, during interval between selective demolition of existing construction on exterior surfaces and new construction, to prevent water leakage and damage to structure and interior areas.
3. Protect walls, ceilings, floors, and other existing finish work that are to remain or that are exposed during selective demolition operations.
4. Cover and protect furniture, furnishings, and equipment that have not been removed.
B. Temporary Shoring: Design, provide, and maintain shoring, bracing, and structural supports as required to preserve stability and prevent movement, settlement, or collapse of construction and finishes to remain, and to prevent unexpected or uncontrolled movement or collapse of construction being demolished.
1. Strengthen or add new supports when required during progress of selective demolition.
C. Remove temporary barricades and protections where hazards no longer exist.
3.5 SELECTIVE DEMOLITION, GENERAL
A. General: Demolish and remove existing construction only to the extent required by new construction and as indicated. Use methods required to complete the Work within limitations of governing regulations and as follows:
1. Proceed with selective demolition systematically, from higher to lower level. Complete selective demolition operations above each floor or tier before disturbing supporting members on the next lower level.
2. Neatly cut openings and holes plumb, square, and true to dimensions required. Use cutting methods least likely to damage construction to remain or adjoining construction. Use hand tools or small power tools designed for sawing or grinding, not hammering and chopping.
Temporarily cover openings to remain.
222
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SELECTIVE DEMOLITION 024119 - 6
3. Cut or drill from the exposed or finished side into concealed surfaces to avoid marring existing finished surfaces.
4. Do not use cutting torches until work area is cleared of flammable materials. At concealed spaces, such as duct and pipe interiors, verify condition and contents of hidden space before starting flame-cutting operations. Maintain portable fire-suppression devices during flamecutting operations.
5. Maintain fire watch during and for at least 2 hours after flame-cutting operations.
6. Maintain adequate ventilation when using cutting torches.
7. Remove decayed, vermin-infested, or otherwise dangerous or unsuitable materials and promptly dispose of off-site.
8. Remove structural framing members and lower to ground by method suitable to avoid free fall and to prevent ground impact or dust generation.
9. Locate selective demolition equipment and remove debris and materials so as not to impose excessive loads on supporting walls, floors, or framing.
10. Dispose of demolished items and materials promptly. Comply with requirements in Section 017419 "Construction Waste Management and Disposal." B. Site Access and Temporary Controls: Conduct selective demolition and debris-removal operations to ensure minimum interference with roads, streets, walks, walkways, and other adjacent occupied and used facilities.
C. Removed and Salvaged Items:
1. Clean salvaged items.
2. Pack or crate items after cleaning. Identify contents of containers.
3. Store items in a secure area until delivery to Owner.
4. Transport items to Owner's storage area designated by Owner.
5. Protect items from damage during transport and storage.
D. Removed and Reinstalled Items:
1. Clean and repair items to functional condition adequate for intended reuse.
2. Pack or crate items after cleaning and repairing. Identify contents of containers.
3. Protect items from damage during transport and storage.
4. Reinstall items in locations indicated. Comply with installation requirements for new materials and equipment. Provide connections, supports, and miscellaneous materials necessary to make item functional for use indicated.
E. Existing Items to Remain: Protect construction indicated to remain against damage and soiling during selective demolition. When permitted by Architect, items may be removed to a suitable, protected storage location during selective demolition and cleaned and reinstalled in their original locations after selective demolition operations are complete.
3.6 SELECTIVE DEMOLITION PROCEDURES FOR SPECIFIC MATERIALS A. Concrete Slabs-on-Grade: Saw-cut perimeter of area to be demolished, and then break up and remove.
223
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
SELECTIVE DEMOLITION 024119 - 7
3.7 DISPOSAL OF DEMOLISHED MATERIALS
A. Remove demolition waste materials from Project site and dispose of them in an EPA-approved construction and demolition waste landfill acceptable to authorities having jurisdiction.
1. Do not allow demolished materials to accumulate on-site.
2. Remove and transport debris in a manner that will prevent spillage on adjacent surfaces and areas.
3. Remove debris from elevated portions of building by chute, hoist, or other device that will convey debris to grade level in a controlled descent.
4. Comply with requirements specified in Section 017419 "Construction Waste Management and Disposal."
B. Burning: Do not burn demolished materials.
3.8 CLEANING
A. Clean adjacent structures and improvements of dust, dirt, and debris caused by selective demolition operations. Return adjacent areas to condition existing before selective demolition operations began.
END OF SECTION 024119
224
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 1
SECTION 033000 - CAST-IN-PLACE CONCRETE
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Cast-in-place concrete, including concrete materials, mixture design, placement procedures, and finishes.
1.2 DEFINITIONS
A. Cementitious Materials: Portland cement alone or in combination with one or more of the following: blended hydraulic cement, fly ash, slag cement, other pozzolans, and silica fume; materials subject to compliance with requirements.
B. Water/Cement Ratio (w/cm): The ratio by weight of water to cementitious materials.
1.3 ACTION SUBMITTALS
A. Product Data: For each of the following.
1. Portland cement.
2. Fly ash.
3. Slag cement.
4. Blended hydraulic cement.
5. Silica fume.
6. Performance-based hydraulic cement
7. Aggregates.
8. Admixtures:
a. Include limitations of use, including restrictions on cementitious materials, supplementary cementitious materials, air entrainment, aggregates, temperature at time of concrete placement, relative humidity at time of concrete placement, curing conditions, and use of other admixtures.
9. Curing materials.
a. Include documentation from color pigment manufacturer, indicating that proposed methods of curing are recommended by color pigment manufacturer.
10. Joint fillers.
11. Repair materials.
B. Design Mixtures: For each concrete mixture, include the following:
1. Mixture identification.
225
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 2
2. Minimum 28-day compressive strength.
3. Durability exposure class.
4. Maximum w/cm.
5. Calculated equilibrium unit weight, for lightweight concrete.
6. Slump limit.
7. Air content.
8. Nominal maximum aggregate size.
9. Steel-fiber reinforcement content.
10. Synthetic micro-fiber content.
11. Indicate amounts of mixing water to be withheld for later addition at Project site if permitted.
12. Include manufacturer's certification that permeability-reducing admixture is compatible with mix design.
13. Include certification that dosage rate for permeability-reducing admixture matches dosage rate used in performance compliance test.
14. Intended placement method.
15. Submit alternate design mixtures when characteristics of materials, Project conditions, weather, test results, or other circumstances warrant adjustments.
1.4 INFORMATIONAL SUBMITTALS
A. Qualification Data: For the following:
1. Installer: Include copies of applicable ACI certificates.
2. Ready-mixed concrete manufacturer.
3. Testing agency: Include copies of applicable ACI certificates.
B. Material Certificates: For each of the following, signed by manufacturers:
1. Cementitious materials.
2. Admixtures.
3. Fiber reinforcement.
4. Curing compounds.
5. Floor and slab treatments.
6. Bonding agents.
7. Adhesives.
8. Vapor retarders.
9. Semirigid joint filler.
10. Joint-filler strips.
11. Repair materials.
C. Floor surface flatness and levelness measurements report, indicating compliance with specified tolerances.
D. Preconstruction Test Reports: For each mix design.
E. Field quality-control reports.
226
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 3
1.5 QUALITY ASSURANCE
A. Installer Qualifications: A qualified installer who employs Project personnel qualified as an ACI-certified Flatwork Technician and Finisher and a supervisor who is a certified ACI Flatwork Concrete Finisher/Technician or an ACI Concrete Flatwork Technician with experience installing and finishing concrete, incorporating permeability-reducing admixtures.
1. Post-Installed Concrete Anchors Installers: ACI-certified Adhesive Anchor Installer.
B. Ready-Mixed Concrete Manufacturer Qualifications: A firm experienced in manufacturing ready-mixed concrete products and that complies with ASTM C94/C94M requirements for production facilities and equipment.
1. Manufacturer certified in accordance with NRMCA's "Certification of Ready Mixed Concrete Production Facilities."
C. Laboratory Testing Agency Qualifications: A testing agency qualified in accordance with ASTM C1077 and ASTM E329 for testing indicated and employing an ACI-certified Concrete Quality Control Technical Manager.
1. Personnel performing laboratory tests to be an ACI-certified Concrete Strength Testing Technician and Concrete Laboratory Testing Technician, Grade I. Testing agency laboratory supervisor to be an ACI-certified Concrete Laboratory Testing Technician, Grade II.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Comply with ASTM C94/C94M and ACI 301 (ACI 301M).
1.7 FIELD CONDITIONS
A. Cold-Weather Placement: Comply with ACI 301 (ACI 301M) and ACI 306.1 and as follows.
1. Protect concrete work from physical damage or reduced strength that could be caused by frost, freezing actions, or low temperatures.
2. When average high and low temperature is expected to fall below 40 deg F (4.4 deg C) for three successive days, maintain delivered concrete mixture temperature within the temperature range required by ACI 301 (ACI 301M).
3. Do not use frozen materials or materials containing ice or snow.
4. Do not place concrete in contact with surfaces less than 35 deg F (1.7 deg C), other than reinforcing steel.
5. Do not use calcium chloride, salt, or other materials containing antifreeze agents or chemical accelerators unless otherwise specified and approved in mixture designs.
B. Hot-Weather Placement: Comply with ACI 301 (ACI 301M) and ACI 305.1 (ACI 305.1M), and as follows:
1. Maintain concrete temperature at time of discharge to not exceed 95 deg F (35 deg C). 227
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 4
2. Fog-spray forms, steel reinforcement, and subgrade just before placing concrete. Keep subgrade uniformly moist without standing water, soft spots, or dry areas.
1.8 WARRANTY
A. Manufacturer's Warranty: Manufacturer agrees to furnish replacement sheet vapor retarder/termite barrier material and accessories for sheet vapor retarder/ termite barrier and accessories that do not comply with requirements or that fail to resist penetration by termites within specified warranty period.
1. Warranty Period: 10 years from date of Substantial Completion.
PART 2 - PRODUCTS
2.1 CONCRETE, GENERAL
A. ACI Publications: Comply with ACI 301 (ACI 301M) unless modified by requirements in the Contract Documents.
2.2 CONCRETE MATERIALS
A. Source Limitations:
1. Obtain all concrete mixtures from a single ready-mixed concrete manufacturer for entire Project.
2. Obtain each type or class of cementitious material of the same brand from the same manufacturer's plant.
3. Obtain aggregate from single source.
4. Obtain each type of admixture from single source from single manufacturer.
B. Cementitious Materials:
1. Portland Cement: ASTM C150/C150M, Type I, gray.
2. Fly Ash: ASTM C618, Class C or F.
3. Slag Cement: ASTM C989/C989M, Grade 100 or 120.
4. Silica Fume: ASTM C1240 amorphous silica.
C. Normal-Weight Aggregates: ASTM C33/C33M, Class 3S, Class 3M, coarse aggregate or better, graded. Provide aggregates from a single source.
1. Alkali-Silica Reaction: Comply with one of the following:
a. Expansion Result of Aggregate: Not more than 0.04 percent at one-year when tested in accordance with ASTM C1293.
b. Expansion Results of Aggregate and Cementitious Materials in Combination: Not more than 0.10 percent at an age of 16 days when tested in accordance with ASTM C1567.
228
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 5
c. Alkali Content in Concrete: Not more than 4 lb./cu. yd. (2.37 kg/cu. m) for moderately reactive aggregate or 3 lb./cu. yd. (1.78 kg/cu. m) for highly reactive aggregate, when tested in accordance with ASTM C1293 and categorized in accordance with ASTM C1778, based on alkali content being calculated in accordance with ACI 301 (ACI 301M).
2. Maximum Coarse-Aggregate Size: 1-1/2 inches (38 mm) nominal.
3. Fine Aggregate: Free of materials with deleterious reactivity to alkali in cement.
D. Lightweight Aggregate: ASTM C330/C330M, 1-inch (25-mm) nominal maximum aggregate size.
E. Air-Entraining Admixture: ASTM C260/C260M.
F. Chemical Admixtures: Certified by manufacturer to be compatible with other admixtures that do not contribute water-soluble chloride ions exceeding those permitted in hardened concrete.
Do not use calcium chloride or admixtures containing calcium chloride in steel-reinforced concrete.
1. Water-Reducing Admixture: ASTM C494/C494M, Type A.
2. Retarding Admixture: ASTM C494/C494M, Type B.
3. Water-Reducing and -Retarding Admixture: ASTM C494/C494M, Type D.
4. High-Range, Water-Reducing Admixture: ASTM C494/C494M, Type F.
5. High-Range, Water-Reducing and -Retarding Admixture: ASTM C494/C494M, Type G.
6. Plasticizing and Retarding Admixture: ASTM C1017/C1017M, Type II.
7. Set-Accelerating Corrosion-Inhibiting Admixture: Commercially formulated, anodic inhibitor or mixed cathodic and anodic inhibitor; capable of forming a protective barrier and minimizing chloride reactions with steel reinforcement in concrete and complying with ASTM C494/C494M, Type C.
8. Non-Set-Accelerating Corrosion-Inhibiting Admixture: Commercially formulated, nonset-accelerating, anodic inhibitor or mixed cathodic and anodic inhibitor; capable of forming a protective barrier and minimizing chloride reactions with steel reinforcement in concrete.
9. Permeability-Reducing Admixture: ASTM C494/C494M, Type S, hydrophilic, permeability-reducing crystalline admixture, capable of reducing water absorption of concrete exposed to hydrostatic pressure (PRAH).
a. Permeability: No leakage when tested in accordance with U.S. Army Corps of Engineers CRD C48 at a hydraulic pressure of 200 psi (1.28 MPa) for 14 days.
G. Water and Water Used to Make Ice: ASTM C94/C94M, potable or complying with ASTM C1602/C1602M, including all limits listed in Table 2 and the requirements of paragraph 5.4
2.3 VAPOR RETARDERS
A. Sheet Vapor Retarder, Class A: ASTM E1745, Class A; not less than 10 mils (0.25 mm) thick.
Include manufacturer's recommended adhesive or pressure-sensitive tape. 229
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 6
B. Sheet Vapor Retarder, Class C: ASTM E1745, Class C; not less than 10 mils (0.25 mm) thick.
Include manufacturer's recommended adhesive or pressure-sensitive joint tape.
C. Sheet Vapor Retarder/Termite Barrier: ASTM E1745, Class A, except with maximum watervapor permeance of 0.03 perms; complying with ICC AC380. Include manufacturer's recommended adhesive or pressure-sensitive tape.
1. Low-Temperature Flexibility: Pass at minus 15 deg F (minus 26 deg C); ASTM D146/D146M.
2. Puncture Resistance: 224 lbf (996 N) minimum; ASTM E154/E154M.
3. Water Absorption: 0.1 percent weight-gain maximum after 48-hour immersion at 70 deg F (21 deg C); ASTM D570.
4. Hydrostatic-Head Resistance: 231 feet (70 m) minimum; ASTM D5385.
D. Bituminous Vapor Retarder: ASTM E1993/E1993M, 110-mil- (2.8-mm-) thick, semiflexible, seven-ply sheet membrane, consisting of reinforced core and carrier sheet with fortified asphalt layers, protective weather coating, and removable plastic release liner. Furnish manufacturer's accessories, including bonding asphalt, pointing mastics, and self-adhering joint tape.
1. Water-Vapor Permeance: 0.0011 grains/h x sq. ft. x inches Hg (0.063 ng/Pa x s x sq. m) when tested in accordance with ASTM E154/E154M.
2. Tensile Strength: 156 lbf/inch (27.35 kN/m) when tested in accordance with ASTM E154/E154M.
3. Puncture Resistance: 140 lbf (662N) when tested in accordance with ASTM E154/E154M.
2.4 CURING MATERIALS
A. Evaporation Retarder: Waterborne, monomolecular film forming, manufactured for application to fresh concrete.
B. Absorptive Cover: AASHTO M 182, Class 2, burlap cloth made from jute or kenaf, weighing approximately 9 oz./sq. yd. (305 g/sq. m) when dry.
C. Moisture-Retaining Cover: ASTM C171, polyethylene film burlap-polyethylene sheet.
1. Color:
a. Ambient Temperature Below 50 deg F (10 deg C): Black. b. Ambient Temperature between 50 deg F (10 deg C) and 85 deg F (29 deg C): Any color.
c. Ambient Temperature Above 85 deg F (29 deg C): White.
D. Curing Paper: 8-feet- (2438-mm-) wide paper, consisting of two layers of fibered kraft paper laminated with double coating of asphalt.
E. Water: Potable or complying with ASTM C1602/C1602M.
F. Clear, Waterborne, Membrane-Forming, Dissipating Curing Compound: ASTM C309, Type 1, Class B.
230
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 7
G. Clear, Waterborne, Membrane-Forming, Nondissipating Curing Compound: ASTM C309, Type 1, Class B, certified by curing compound manufacturer to not interfere with bonding of floor covering.
H. Clear, Waterborne, Membrane-Forming, Curing Compound: ASTM C309, Type 1, Class B, 18 to 25 percent solids, nondissipating, certified by curing compound manufacturer to not interfere with bonding of floor covering.
I. Clear, Solvent-Borne, Membrane-Forming, Curing and Sealing Compound: ASTM C1315, Type 1, Class A.
J. Clear, Waterborne, Membrane-Forming, Curing and Sealing Compound: ASTM C1315, Type 1, Class A.
2.5 RELATED MATERIALS
A. Expansion- and Isolation-Joint-Filler Strips: ASTM D1751, asphalt-saturated cellulosic fiber or ASTM D1752, cork or self-expanding cork.
B. Semirigid Joint Filler: Two-component, semirigid, 100 percent solids, epoxy resin with a Type A shore durometer hardness of 80 in accordance with ASTM D2240.
C. Bonding Agent: ASTM C1059/C1059M, Type II, nonredispersible, acrylic emulsion or styrene butadiene.
D. Epoxy Bonding Adhesive: ASTM C881, two-component epoxy resin, capable of humid curing and bonding to damp surfaces, of class suitable for application temperature and of grade and class to suit requirements, and as follows:
1. Types I and II, nonload bearing, for bonding hardened or freshly mixed concrete to hardened concrete.
2.6 REPAIR MATERIALS
A. Repair Underlayment: Cement-based, polymer-modified, self-leveling product that can be applied in thicknesses from 1/8 inch (3 mm) and that can be feathered at edges to match adjacent floor elevations.
1. Cement Binder: ASTM C150/C150M portland cement or hydraulic or blended hydraulic cement, as defined in ASTM C219.
2. Primer: Product of underlayment manufacturer recommended for substrate, conditions, and application.
3. Aggregate: Well-graded, washed gravel, 1/8 to 1/4 inch (3 to 6 mm) or coarse sand, as recommended by underlayment manufacturer.
4. Compressive Strength: Not less than 4100 psi (29 MPa) at 28 days when tested in accordance with ASTM C109/C109M.
231
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 8
B. Repair Overlayment: Cement-based, polymer-modified, self-leveling product that can be applied in thicknesses from 1/4 inch (6 mm) and that can be filled in over a scarified surface to match adjacent floor elevations.
1. Cement Binder: ASTM C150/C150M portland cement or hydraulic or blended hydraulic cement, as defined in ASTM C219.
2. Primer: Product of topping manufacturer recommended for substrate, conditions, and application.
3. Aggregate: Well-graded, washed gravel, 1/8 to 1/4 inch (3.2 to 6 mm) or coarse sand as recommended by topping manufacturer.
4. Compressive Strength: Not less than 5000 psi (34.5 MPa) at 28 days when tested in accordance with ASTM C109/C109M.
2.7 CONCRETE MIXTURES, GENERAL
A. Prepare design mixtures for each type and strength of concrete, proportioned on the basis of laboratory trial mixture or field test data, or both, in accordance with ACI 301 (ACI 301M).
1. Use a qualified testing agency for preparing and reporting proposed mixture designs, based on laboratory trial mixtures.
B. Cementitious Materials: Limit percentage, by weight, of cementitious materials other than portland cement in concrete as follows:
1. Fly Ash or Other Pozzolans: 25 percent by mass.
2. Slag Cement: 50 percent by mass.
3. Silica Fume: 10 percent by mass.
4. Total of Fly Ash or Other Pozzolans, Slag Cement, and Silica Fume: 50 percent by mass, with fly ash or pozzolans not exceeding 25 percent by mass and silica fume not exceeding 10 percent by mass.
5. Total of Fly Ash or Other Pozzolans and Silica Fume: 35 percent by mass with fly ash or pozzolans not exceeding 25 percent by mass and silica fume not exceeding 10 percent by mass.
C. Admixtures: Use admixtures in accordance with manufacturer's written instructions.
1. Use water-reducing, high-range water-reducing, or plasticizing admixture in concrete, as required, for placement and workability.
2. Use water-reducing and -retarding admixture when required by high temperatures, low humidity, or other adverse placement conditions.
3. Use water-reducing admixture in pumped concrete, concrete for heavy-use industrial slabs, concrete for parking structure slabs, and concrete with a w/cm below 0.50.
4. Use corrosion-inhibiting admixture in concrete mixtures where indicated.
5. Use permeability-reducing admixture in concrete mixtures where indicated.
D. Color Pigment: Add color pigment to concrete mixture in accordance with manufacturer's written instructions and to result in hardened concrete color consistent with approved mockup. 232
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 9
2.8 CONCRETE MIXTURES
A. Class A Normal-weight concrete used for footings, grade beams, and tie beams.
1. Exposure Class: ACI 318 (ACI 318M) F0.
2. Minimum Compressive Strength: 4000 psi (27.6 MPa) at 28 days.
3. Maximum w/cm: 0.50.
4. Slump Limit: 4 inches (100 mm), plus or minus 1 inch (25 mm).
5. Slump Flow Limit: 22 inches (550 mm), plus or minus 1.5 inches (40 mm).
6. Air Content:
7. Limit water-soluble, chloride-ion content in hardened concrete to 1.00 percent by weight of cement.
2.9 CONCRETE MIXING
A. Ready-Mixed Concrete: Measure, batch, mix, and deliver concrete in accordance with ASTM C94/C94M and ASTM C1116/C1116M, and furnish batch ticket information.
B. Project-Site Mixing: Measure, batch, and mix concrete materials and concrete in accordance with ASTM C94/C94M. Mix concrete materials in appropriate drum-type batch machine mixer.
1. For mixer capacity of 1 cu. yd. (0.76 cu. m) or smaller, continue mixing at least 1-1/2 minutes, but not more than five minutes after ingredients are in mixer, before any part of batch is released.
2. For mixer capacity larger than 1 cu. yd. (0.76 cu. m), increase mixing time by 15 seconds for each additional 1 cu. yd. (0.76 cu. m).
3. Provide batch ticket for each batch discharged and used in the Work, indicating Project identification name and number, date, mixture type, mixture time, quantity, and amount of water added. Record approximate location of final deposit in structure.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Verification of Conditions:
1. Before placing concrete, verify that installation of concrete forms, accessories, and reinforcement, and embedded items is complete and that required inspections have been performed.
2. Do not proceed until unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Provide reasonable auxiliary services to accommodate field testing and inspections, acceptable to testing agency, including the following:
1. Daily access to the Work.
233
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 10
2. Incidental labor and facilities necessary to facilitate tests and inspections.
3. Secure space for storage, initial curing, and field curing of test samples, including source of water and continuous electrical power at Project site during site curing period for test samples.
4. Security and protection for test samples and for testing and inspection equipment at Project site.
3.3 INSTALLATION OF EMBEDDED ITEMS
A. Place and secure anchorage devices and other embedded items required for adjoining Work that is attached to or supported by cast-in-place concrete.
1. Use setting drawings, templates, diagrams, instructions, and directions furnished with items to be embedded.
2. Install anchor rods, accurately located, to elevations required and complying with tolerances in Section 7.5 of ANSI/AISC 303.
3. Install reglets to receive waterproofing and to receive through-wall flashings in outer face of concrete frame at exterior walls, where flashing is shown at lintels, shelf angles, and other conditions.
3.4 INSTALLATION OF VAPOR RETARDER
A. Sheet Vapor Retarders: Place, protect, and repair sheet vapor retarder in accordance with ASTM E1643 and manufacturer's written instructions.
1. Install vapor retarder with longest dimension parallel with direction of concrete pour.
2. Face laps away from exposed direction of concrete pour.
3. Lap vapor retarder over footings and grade beams not less than 6 inches (150 mm), sealing vapor retarder to concrete.
4. Lap joints 6 inches (150 mm) and seal with manufacturer's recommended tape.
5. Terminate vapor retarder at the top of floor slabs, grade beams, and pile caps, sealing entire perimeter to floor slabs, grade beams, foundation walls, or pile caps.
6. Seal penetrations in accordance with vapor retarder manufacturer's instructions.
7. Protect vapor retarder during placement of reinforcement and concrete. a. Repair damaged areas by patching with vapor retarder material, overlapping damages area by 6 inches (150 mm) on all sides, and sealing to vapor retarder.
B. Bituminous Vapor Retarders: Place, protect, and repair bituminous vapor retarder in accordance with manufacturer's written instructions.
3.5 CONCRETE PLACEMENT
A. Before placing concrete, verify that installation of formwork, reinforcement, embedded items, and vapor retarder is complete and that required inspections are completed.
1. Immediately prior to concrete placement, inspect vapor retarder for damage and deficient installation, and repair defective areas.
234
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 11
2. Provide continuous inspection of vapor retarder during concrete placement and make necessary repairs to damaged areas as Work progresses.
B. Notify Engineer and testing and inspection agencies 24 hours prior to commencement of concrete placement.
C. Do not add water to concrete during delivery, at Project site, or during placement unless approved by Architect in writing, but not to exceed the amount indicated on the concrete delivery ticket.
1. Do not add water to concrete after adding high-range water-reducing admixtures to mixture.
D. Before test sampling and placing concrete, water may be added at Project site, subject to limitations of ACI 301 (ACI 301M), but not to exceed the amount indicated on the concrete delivery ticket.
1. Do not add water to concrete after adding high-range water-reducing admixtures to mixture.
E. Deposit concrete continuously in one layer or in horizontal layers of such thickness that no new concrete is placed on concrete that has hardened enough to cause seams or planes of weakness.
1. If a section cannot be placed continuously, provide construction joints as indicated.
2. Deposit concrete to avoid segregation.
3. Deposit concrete in horizontal layers of depth not to exceed formwork design pressures and in a manner to avoid inclined construction joints.
4. Consolidate placed concrete with mechanical vibrating equipment in accordance with ACI 301 (ACI 301M).
a. Do not use vibrators to transport concrete inside forms. b. Insert and withdraw vibrators vertically at uniformly spaced locations to rapidly penetrate placed layer and at least 6 inches (150 mm) into preceding layer. c. Do not insert vibrators into lower layers of concrete that have begun to lose plasticity.
d. At each insertion, limit duration of vibration to time necessary to consolidate concrete, and complete embedment of reinforcement and other embedded items without causing mixture constituents to segregate.
F. Deposit and consolidate concrete for floors and slabs in a continuous operation, within limits of construction joints, until placement of a panel or section is complete.
1. Do not place concrete floors and slabs in a checkerboard sequence.
2. Consolidate concrete during placement operations, so concrete is thoroughly worked around reinforcement and other embedded items and into corners.
3. Maintain reinforcement in position on chairs during concrete placement.
4. Screed slab surfaces with a straightedge and strike off to correct elevations.
5. Level concrete, cut high areas, and fill low areas.
6. Slope surfaces uniformly to drains where required.
7. Begin initial floating using bull floats or darbies to form a uniform and open-textured surface plane, before excess bleedwater appears on the surface. 235
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 12
8. Do not further disturb slab surfaces before starting finishing operations.
3.6 FINISHING FORMED SURFACES
A. As-Cast Surface Finishes:
1. ACI 301 (ACI 301M) Surface Finish SF-1.0: As-cast concrete texture imparted by formfacing material. a. Patch voids larger than 1-1/2 inches (38 mm) wide or 1/2 inch (13 mm) deep. b. Remove projections larger than 1 inch (25 mm).
c. Tie holes do not require patching.
d. Surface Tolerance: ACI 117 (ACI 117M) Class D.
e. Apply to concrete surfaces not exposed to public view.
2. ACI 301 (ACI 301M) Surface Finish SF-2.0: As-cast concrete texture imparted by formfacing material, arranged in an orderly and symmetrical manner with a minimum of seams.
a. Patch voids larger than 3/4 inch (19 mm) wide or 1/2 inch (13 mm) deep. b. Remove projections larger than 1/4 inch (6 mm).
c. Patch tie holes.
d. Surface Tolerance: ACI 117 (ACI 117M) Class B.
e. Locations: Apply to concrete surfaces exposed to public view, to receive a rubbed finish, or to be covered with a coating or covering material applied directly to concrete.
3. ACI 301 (ACI 301M) Surface Finish SF-3.0:
a. Patch voids larger than 3/4 inch (19 mm) wide or 1/2 inch (13 mm) deep. b. Remove projections larger than 1/8 inch (3 mm).
c. Patch tie holes.
d. Surface Tolerance: ACI 117 (ACI 117M) Class A.
e. Locations: Apply to concrete surfaces exposed to public view, to receive a rubbed finish, or to be covered with a coating or covering material applied directly to concrete.
3.7 INSTALLATION OF MISCELLANEOUS CONCRETE ITEMS
A. Equipment Bases and Foundations:
1. Coordinate sizes and locations of concrete bases with actual equipment provided.
2. Construct concrete bases 4 inches (100 mm) high unless otherwise indicated on Drawings, and extend base not less than 6 inches (150 mm) in each direction beyond the maximum dimensions of supported equipment unless otherwise indicated on Drawings, or unless required for seismic anchor support.
3. Minimum Compressive Strength: 4000 psi (27.6 MPa) at 28 days.
4. For supported equipment, install epoxy-coated anchor bolts that extend through concrete base and anchor into structural concrete substrate.
236
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 13
5. Prior to pouring concrete, place and secure anchorage devices. a. Use setting drawings, templates, diagrams, instructions, and directions furnished with items to be embedded.
b. Cast anchor-bolt insert into bases.
c. Install anchor bolts to elevations required for proper attachment to supported equipment.
3.8 CONCRETE CURING
A. Protect freshly placed concrete from premature drying and excessive cold or hot temperatures.
1. Comply with ACI 301 (ACI 301M) and ACI 306.1 for cold weather protection during curing.
2. Comply with ACI 301 (ACI 301M) and ACI 305.1 (ACI 305.1M) for hot-weather protection during curing.
3. Maintain moisture loss no more than 0.2 lb/sq. ft. x h (1 kg/sq. m x h), calculated in accordance with ACI 305.1, before and during finishing operations.
B. Curing Formed Surfaces: Comply with ACI 308.1 (ACI 308.1M) as follows:
1. Cure formed concrete surfaces, including underside of beams, supported slabs, and other similar surfaces.
2. Cure concrete containing color pigments in accordance with color pigment manufacturer's instructions.
3. If forms remain during curing period, moist cure after loosening forms.
4. If removing forms before end of curing period, continue curing for remainder of curing period, as follows:
a. Continuous Fogging: Maintain standing water on concrete surface until final setting of concrete.
b. Continuous Sprinkling: Maintain concrete surface continuously wet. c. Absorptive Cover: Pre-dampen absorptive material before application; apply additional water to absorptive material to maintain concrete surface continuously wet.
d. Water-Retention Sheeting Materials: Cover exposed concrete surfaces with sheeting material, taping, or lapping seams.
e. Membrane-Forming Curing Compound: Apply uniformly in continuous operation by power spray or roller in accordance with manufacturer's written instructions. 1) Recoat areas subject to heavy rainfall within three hours after initial application.
2) Maintain continuity of coating and repair damage during curing period.
C. Curing Unformed Surfaces: Comply with ACI 308.1 (ACI 308.1M) as follows:
1. Begin curing immediately after finishing concrete.
2. Interior Concrete Floors:
237
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 14
a. Floors to Receive Floor Coverings Specified in Other Sections: Contractor has option of the following:
1) Absorptive Cover: As soon as concrete has sufficient set to permit application without marring concrete surface, install prewetted absorptive cover over entire area of floor.
a) Lap edges and ends of absorptive cover not less than 12 inches (300 mm).
b) Maintain absorptive cover water saturated, and in place, for duration of curing period, but not less than seven days.
2) Moisture-Retaining-Cover Curing: Cover concrete surfaces with moistureretaining cover for curing concrete, placed in widest practicable width, with sides and ends lapped at least 12 inches (300 mm), and sealed by waterproof tape or adhesive.
a) Immediately repair any holes or tears during curing period, using cover material and waterproof tape.
b) Cure for not less than seven days.
3) Ponding or Continuous Sprinkling of Water: Maintain concrete surfaces continuously wet for not less than seven days, utilizing one, or a combination of, the following:
a) Water.
b) Continuous water-fog spray.
b. Floors to Receive Penetrating Liquid Floor Treatments: Contractor has option of the following:
1) Absorptive Cover: As soon as concrete has sufficient set to permit application without marring concrete surface, install prewetted absorptive cover over entire area of floor.
a) Lap edges and ends of absorptive cover not less than 12 inches (300 mm).
b) Maintain absorptive cover water saturated, and in place, for duration of curing period, but not less than seven days.
2) Moisture-Retaining-Cover Curing: Cover concrete surfaces with moistureretaining cover for curing concrete, placed in widest practicable width, with sides and ends lapped at least 12 inches (300 mm), and sealed by waterproof tape or adhesive.
a) Immediately repair any holes or tears during curing period, using cover material and waterproof tape.
b) Cure for not less than seven days.
238
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 15
3) Ponding or Continuous Sprinkling of Water: Maintain concrete surfaces continuously wet for not less than seven days, utilizing one, or a combination of, the following:
a) Water.
b) Continuous water-fog spray.
c. Floors to Receive Polished Finish: Contractor has option of the following:
1) Absorptive Cover: As soon as concrete has sufficient set to permit application without marring concrete surface, install prewetted absorptive cover over entire area of floor.
a) Lap edges and ends of absorptive cover not less than 12 inches (300 mm).
b) Maintain absorptive cover water saturated, and in place, for duration of curing period, but not less than seven days.
2) Ponding or Continuous Sprinkling of Water: Maintain concrete surfaces continuously wet for not less than seven days, utilizing one, or a combination of, the following:
a) Water.
b) Continuous water-fog spray.
d. Floors to Receive Chemical Stain:
1) As soon as concrete has sufficient set to permit application without marring concrete surface, install curing paper over entire area of floor. 2) Install curing paper square to building lines, without wrinkles, and in a single length without end joints.
3) Butt sides of curing paper tight; do not overlap sides of curing paper. 4) Leave curing paper in place for duration of curing period, but not less than 28 days.
e. Floors to Receive Urethane Flooring:
1) As soon as concrete has sufficient set to permit application without marring concrete surface, install prewetted absorptive cover over entire area of floor. 2) Rewet absorptive cover, and cover immediately with polyethylene moistureretaining cover with edges lapped 6 inches (150 mm) and sealed in place. 3) Secure polyethylene moisture-retaining cover in place to prohibit air from circulating under polyethylene moisture-retaining cover. 4) Leave absorptive cover and polyethylene moisture-retaining cover in place for duration of curing period, but not less than 28 days. f. Floors to Receive Curing Compound:
1) Apply uniformly in continuous operation by power spray or roller in accordance with manufacturer's written instructions.
239
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 16
2) Recoat areas subjected to heavy rainfall within three hours after initial application.
3) Maintain continuity of coating, and repair damage during curing period. 4) Removal: After curing period has elapsed, remove curing compound without damaging concrete surfaces by method recommended by curing compound manufacturer unless manufacturer certifies curing compound does not interfere with bonding of floor covering used on Project. g. Floors to Receive Curing and Sealing Compound:
1) Apply uniformly to floors and slabs indicated in a continuous operation by power spray or roller in accordance with manufacturer's written instructions. 2) Recoat areas subjected to heavy rainfall within three hours after initial application.
3) Repeat process 24 hours later, and apply a second coat. Maintain continuity of coating, and repair damage during curing period.
3.9 TOLERANCES
A. Conform to ACI 117 (ACI 117M).
3.10 JOINT FILLING
A. Prepare, clean, and install joint filler in accordance with manufacturer's written instructions.
1. Defer joint filling until concrete has aged at least one month(s).
2. Do not fill joints until construction traffic has permanently ceased.
B. Remove dirt, debris, saw cuttings, curing compounds, and sealers from joints; leave contact faces of joints clean and dry.
C. Install semirigid joint filler full depth in saw-cut joints and at least 2 inches (50 mm) deep in formed joints.
D. Overfill joint, and trim joint filler flush with top of joint after hardening.
3.11 CONCRETE SURFACE REPAIRS
A. Defective Concrete:
1. Repair and patch defective areas when approved by Architect.
2. Remove and replace concrete that cannot be repaired and patched to Architect's approval.
B. Patching Mortar: Mix dry-pack patching mortar, consisting of 1 part portland cement to 2-1/2 parts fine aggregate passing a No. 16 (1.18-mm) sieve, using only enough water for handling and placing.
240
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 17
C. Repairing Formed Surfaces: Surface defects include color and texture irregularities, cracks, spalls, air bubbles, honeycombs, rock pockets, fins and other projections on the surface, and stains and other discolorations that cannot be removed by cleaning.
1. Immediately after form removal, cut out honeycombs, rock pockets, and voids more than 1/2 inch (13 mm) in any dimension to solid concrete.
a. Limit cut depth to 3/4 inch (19 mm).
b. Make edges of cuts perpendicular to concrete surface. c. Clean, dampen with water, and brush-coat holes and voids with bonding agent. d. Fill and compact with patching mortar before bonding agent has dried. e. Fill form-tie voids with patching mortar or cone plugs secured in place with bonding agent.
2. Repair defects on surfaces exposed to view by blending white portland cement and standard portland cement, so that, when dry, patching mortar matches surrounding color. a. Patch a test area at inconspicuous locations to verify mixture and color match before proceeding with patching.
b. Compact mortar in place and strike off slightly higher than surrounding surface.
3. Repair defects on concealed formed surfaces that will affect concrete's durability and structural performance as determined by Architect.
D. Repairing Unformed Surfaces:
1. Test unformed surfaces, such as floors and slabs, for finish, and verify surface tolerances specified for each surface.
a. Correct low and high areas.
b. Test surfaces sloped to drain for trueness of slope and smoothness; use a sloped template.
2. Repair finished surfaces containing surface defects, including spalls, popouts, honeycombs, rock pockets, crazing, and cracks in excess of 0.01 inch (0.25 mm) wide or that penetrate to reinforcement or completely through unreinforced sections regardless of width, and other objectionable conditions.
3. After concrete has cured at least 14 days, correct high areas by grinding.
4. Correct localized low areas during, or immediately after, completing surface-finishing operations by cutting out low areas and replacing with patching mortar. a. Finish repaired areas to blend into adjacent concrete.
5. Correct other low areas scheduled to receive floor coverings with a repair underlayment. a. Prepare, mix, and apply repair underlayment and primer in accordance with manufacturer's written instructions to produce a smooth, uniform, plane, and level surface.
b. Feather edges to match adjacent floor elevations.
6. Correct other low areas scheduled to remain exposed with repair topping. 241
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 18
a. Cut out low areas to ensure a minimum repair topping depth of 1/4 inch (6 mm) to match adjacent floor elevations.
b. Prepare, mix, and apply repair topping and primer in accordance with manufacturer's written instructions to produce a smooth, uniform, plane, and level surface.
7. Repair defective areas, except random cracks and single holes 1 inch (25 mm) or less in diameter, by cutting out and replacing with fresh concrete. a. Remove defective areas with clean, square cuts, and expose steel reinforcement with at least a 3/4-inch (19-mm) clearance all around.
b. Dampen concrete surfaces in contact with patching concrete and apply bonding agent.
c. Mix patching concrete of same materials and mixture as original concrete, except without coarse aggregate.
d. Place, compact, and finish to blend with adjacent finished concrete. e. Cure in same manner as adjacent concrete.
8. Repair random cracks and single holes 1 inch (25 mm) or less in diameter with patching mortar.
a. Groove top of cracks and cut out holes to sound concrete, and clean off dust, dirt, and loose particles.
b. Dampen cleaned concrete surfaces and apply bonding agent. c. Place patching mortar before bonding agent has dried. d. Compact patching mortar and finish to match adjacent concrete. e. Keep patched area continuously moist for at least 72 hours.
E. Perform structural repairs of concrete, subject to Architect's approval, using epoxy adhesive and patching mortar.
F. Repair materials and installation not specified above may be used, subject to Architect's approval.
3.12 FIELD QUALITY CONTROL
A. Special Inspections: Contractor will engage a special inspector to perform field tests and inspections and prepare testing and inspection reports.
B. Testing Agency: Engage a qualified testing and inspecting agency to perform tests and inspections and to submit reports.
1. Testing agency to be responsible for providing curing container for composite samples on Site and verifying that field-cured composite samples are cured in accordance with ASTM C31/C31M.
2. Testing agency to immediately report to Architect, Contractor, and concrete manufacturer any failure of Work to comply with Contract Documents.
3. Testing agency to report results of tests and inspections, in writing, to Owner, Architect, Contractor, and concrete manufacturer within 48 hours of inspections and tests. 242
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 19
a. Test reports to include reporting requirements of ASTM C31/C31M, ASTM C39/C39M, and ACI 301, including the following as applicable to each test and inspection:
1) Project name.
2) Name of testing agency.
3) Names and certification numbers of field and laboratory technicians performing inspections and testing.
4) Name of concrete manufacturer.
5) Date and time of inspection, sampling, and field testing. 6) Date and time of concrete placement.
7) Location in Work of concrete represented by samples. 8) Date and time sample was obtained.
9) Truck and batch ticket numbers.
10) Design compressive strength at 28 days.
11) Concrete mixture designation, proportions, and materials. 12) Field test results.
13) Information on storage and curing of samples before testing, including curing method and maximum and minimum temperatures during initial curing period.
14) Type of fracture and compressive break strengths at seven days and 28 days.
C. Batch Tickets: For each load delivered, submit three copies of batch delivery ticket to testing agency, indicating quantity, mix identification, admixtures, design strength, aggregate size, design air content, design slump at time of batching, and amount of water that can be added at Project site.
D. Inspections:
1. Verification of use of required design mixture.
2. Concrete placement, including conveying and depositing.
3. Curing procedures and maintenance of curing temperature.
4. Verification of concrete strength before removal of shores and forms from beams and slabs.
5. Batch Plant Inspections: On a random basis, as determined by Architect.
E. Concrete Tests: Testing of composite samples of fresh concrete obtained in accordance with ASTM C 172/C 172M to be performed in accordance with the following requirements:
1. Testing Frequency: Obtain one composite sample for each day's pour of each concrete mixture exceeding 5 cu. yd. (4 cu. m), but less than 25 cu. yd. (19 cu. m), plus one set for each additional 50 cu. yd. (38 cu. m) or fraction thereof. a. When frequency of testing provides fewer than five compressive-strength tests for each concrete mixture, testing to be conducted from at least five randomly selected batches or from each batch if fewer than five are used.
2. Slump: ASTM C143/C143M:
a. One test at point of placement for each composite sample, but not less than one test for each day's pour of each concrete mixture.
b. Perform additional tests when concrete consistency appears to change. 243
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 20
3. Slump Flow: ASTM C1611/C1611M:
a. One test at point of placement for each composite sample, but not less than one test for each day's pour of each concrete mixture.
b. Perform additional tests when concrete consistency appears to change.
4. Air Content: ASTM C231/C231M pressure method, for normal-weight concrete; ASTM C173/C173M volumetric method, for structural lightweight concrete. a. One test for each composite sample, but not less than one test for each day's pour of each concrete mixture.
5. Concrete Temperature: ASTM C1064/C1064M:
a. One test hourly when air temperature is 40 deg F (4.4 deg C) and below or 80 deg F (27 deg C) and above, and one test for each composite sample.
6. Unit Weight: ASTM C567/C567M fresh unit weight of structural lightweight concrete. a. One test for each composite sample, but not less than one test for each day's pour of each concrete mixture.
7. Compression Test Specimens: ASTM C31/C31M:
a. Cast and laboratory cure two sets of three 6-inch (150 mm) by 12-inch (300 mm) or 4-inch (100 mm) by 8-inch (200 mm) cylinder specimens for each composite sample.
b. Cast, initial cure, and field cure two sets of four standard cylinder specimens for each composite sample.
8. Compressive-Strength Tests: ASTM C39/C39M.
a. Test one set of two laboratory-cured specimens at seven days and one set of two specimens at 28 days.
b. Test one set of two field-cured specimens at seven days and one set of two specimens at 28 days.
c. A compressive-strength test to be the average compressive strength from a set of two specimens obtained from same composite sample and tested at age indicated.
9. When strength of field-cured cylinders is less than 85 percent of companion laboratorycured cylinders, Contractor to evaluate operations and provide corrective procedures for protecting and curing in-place concrete.
10. Strength of each concrete mixture will be satisfactory if every average of any three consecutive compressive-strength tests equals or exceeds specified compressive strength, and no compressive-strength test value falls below specified compressive strength by more than 500 psi (3.4 MPa) if specified compressive strength is 5000 psi (34.5 MPa), or no compressive strength test value is less than 10 percent of specified compressive strength if specified compressive strength is greater than 5000 psi (34.5 MPa).
11. Nondestructive Testing: Impact hammer, sonoscope, or other nondestructive device may be permitted by Architect but will not be used as sole basis for approval or rejection of concrete.
244
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
CAST-IN-PLACE CONCRETE 033000 - 21
F. Measure floor and slab flatness and levelness in accordance with ASTM E1155 (ASTM E1155M) within 24 hours of completion of floor finishing and promptly report test results to Architect.
3.13 PROTECTION
A. Protect concrete surfaces as follows:
1. Protect from petroleum stains.
2. Diaper hydraulic equipment used over concrete surfaces.
3. Prohibit vehicles from interior concrete slabs.
4. Prohibit use of pipe-cutting machinery over concrete surfaces.
5. Prohibit placement of steel items on concrete surfaces.
6. Prohibit use of acids or acidic detergents over concrete surfaces.
7. Protect liquid floor treatment from damage and wear during the remainder of construction period. Use protective methods and materials, including temporary covering, recommended in writing by liquid floor treatments installer.
8. Protect concrete surfaces scheduled to receive surface hardener or polished concrete finish using Floor Slab Protective Covering.
END OF SECTION 033000
245
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXISTING HVAC AIR DISTRIBUTION SYSTEM CLEANING 230130.52 - 1 SECTION 230130.52 - EXISTING HVAC AIR DISTRIBUTION SYSTEM CLEANING PART 1 - GENERAL
1.1 SUMMARY
A. Section includes cleaning existing HVAC air-distribution equipment, ducts, plenums, and system components.
B. Related Requirements:
1. Section 233113.00 "Metal Ducts" for cleaning newly installed metal ducts.
2. Section 230593.00 "Testing, Adjusting, Balancing for HVAC" for system flow documentation before cleaning and balancing and following cleaning and restoration.
3. Section 233300.00 "Air Duct Accessories" for restoration of opened ducts and plenums with access doors.
1.2 DEFINITIONS
A. ACAC: American Council for Accredited Certification.
B. AIHA-LAP: American Industrial Hygiene Association Lab Accreditation Program C. ASCS: Air systems cleaning specialist.
D. CESB: Council of Engineering and Scientific Specialty Boards.
E. CMI: Certified Microbial Investigator.
F. CMC: Certified Microbial Consultant.
G. CMR: Certified Microbial Remediator.
H. CMRS: Certified Microbial Remediation Supervisor.
I. EMLAP: Environmental Microbiology Laboratory Accreditation Program.
J. IEP: Indoor Environmental Professional.
K. IICRC: Institute of Inspection, Cleaning, and Restoration Certification.
L. NADCA: National Air Duct Cleaners Association.
1.3 ACTION SUBMITTALS
A. Product Data:
246
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXISTING HVAC AIR DISTRIBUTION SYSTEM CLEANING 230130.52 - 2
1. Cleaning agents
2. Antimicrobial surface treatments "sealant" for sustainable design submittal purposes.
1.4 INFORMATIONAL SUBMITTALS
A. Qualification Data:
1. For an ASCS.
2. For an IEP.
3. For a CMR and a CMRS.
B. Field Quality-Control Reports:
1. Project's existing conditions.
2. Evaluations and recommendations, including cleanliness verification.
3. Strategies and procedures plan.
1.5 CLOSEOUT SUBMITTALS
A. Post-Project report.
1.6 QUALITY ASSURANCE
A. ASCS Qualifications: A certified member of NADCA.
1. Certification: Employ an ASCS certified by NADCA on a full-time basis.
2. Supervisor Qualifications: Certified as an ASCS by NADCA.
B. IEP Qualifications: CMI who is certified by ACAC and accredited by CESB.
C. IEP Qualifications: CMC who is certified by ACAC and accredited by CESB.
D. CMR Qualifications: Certified by ACAC and accredited by CESB.
E. CMRS Qualifications: Certified by ACAC and accredited by CESB.
F. UL Compliance: Comply with UL 181 and UL 181A for fibrous-glass ducts.
PART 2 - PRODUCTS
2.1 HVAC CLEANING AGENTS
A. Description:
1. Formulated for each specific soiled coil condition that needs remedy.
2. Will not corrode or tarnish aluminum, copper, or other metals. 247
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXISTING HVAC AIR DISTRIBUTION SYSTEM CLEANING 230130.52 - 3
2.2 ANTIMICROBIAL SURFACE TREATMENT
A. Description: Specific product selected shall be as recommended by the IEP based on the specific antimicrobial needs of the specific Project conditions.
1. Formulated to kill and inhibit growth of microorganisms.
2. EPA-registered for use in HVAC systems and for the specific application in which it will be used.
3. Have no residual action after drying, with zero VOC off-gassing.
4. OSHA compliant.
5. Treatment shall dry clear to allow continued visual observation of the treated surface.
PART 3 - EXECUTION
3.1 PREPARATION
A. Inspect HVAC air-distribution equipment, ducts, plenums, and system components to determine appropriate methods, tools, and equipment required for performance of the Work.
B. Perform "Project Evaluation and Recommendation" according to NADCA ACR.
C. Cleaning Plan: Prepare a written plan for air-distribution system cleaning that includes strategies and step-by-step procedures. At a minimum, include the following:
1. Supervisor contact information.
2. Work schedule, including location, times, and impact on occupied areas.
3. Methods and materials planned for each HVAC component type.
4. Required support from other trades.
5. Equipment and material storage requirements.
6. Exhaust equipment setup locations.
D. Existing Conditions Report: Prepare a written report that documents existing conditions of the systems and equipment. Include documentation of existing conditions, including inspection results, photo images, laboratory results, and interpretations of the laboratory results by an IEP.
1. Prepare written report listing conditions detrimental to performance of the Work.
E. Proceed with work only after conditions detrimental to performance of the Work have been corrected.
F. Use the existing service openings, as required for proper cleaning, at various points of the HVAC system for physical and mechanical entry and for inspection.
G. Comply with NADCA ACR, "Guidelines for Constructing Service Openings in HVAC Systems" Section.
H. Mark the position of manual volume dampers and air-directional mechanical devices inside the system prior to cleaning.
248
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXISTING HVAC AIR DISTRIBUTION SYSTEM CLEANING 230130.52 - 4
3.2 CLEANING
A. Comply with NADCA ACR, including items identified as "recommended," "advised," and "suggested."
B. Perform electrical lockout and tagout according to Owner's standards or authorities having jurisdiction.
C. Remove non-adhered substances and deposits from within the HVAC system.
D. Complete cleaning in accordance with Owner-Contractor agreed-upon scope of work.
E. Systems and Components to Be Cleaned: All air-moving and -distribution equipment.
F. Systems and Components to Be Cleaned:
1. Air devices for supply and return air.
2. Air-terminal units and connections.
a. Fan coil units.
b. Unit ventilators.
c. Flexible connectors.
3. Ductwork:
a. Supply-air ducts, including turning vanes and reheat coils, to the air-handling unit. b. Return-air ducts to the air-handling unit.
c. Exhaust-air ducts.
d. Transfer ducts.
4. Casings.
5. Duct-mounted coils.
6. Air-Handling Units:
a. Interior surfaces of the unit casing.
b. Coil surfaces compartment.
c. Condensate drain pans.
d. Fans, fan blades, and fan housings.
7. Exhaust fans and power ventilators.
8. Filters and filter housings.
9. Gravity ventilators.
10. Air-to-air heat exchangers.
G. Collect debris removed during cleaning. Ensure that debris is not dispersed outside the HVAC system during the cleaning process.
H. Particulate Collection:
1. For particulate collection equipment, include adequate filtration to contain debris removed. Locate equipment downwind and away from all air intakes and other points of entry into the building.
249
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXISTING HVAC AIR DISTRIBUTION SYSTEM CLEANING 230130.52 - 5
2. HEPA filtration with 99.97 percent collection efficiency for particles sized 0.3 micrometer or larger shall be used where the particulate collection equipment is exhausting inside the building,
I. Control odors and mist vapors during the cleaning and restoration process.
J. Mark the position of manual volume dampers and air-directional mechanical devices inside the system prior to cleaning. Restore them to their marked position on completion of cleaning.
K. System components shall be cleaned so that all HVAC system components are visibly clean. On completion, all components must be returned to those settings recorded just prior to cleaning operations.
L. Clean all air-distribution devices, registers, grilles, and diffusers.
M. Clean non-adhered substance deposits according to NADCA ACR and the following:
1. Clean air-handling units, airstream surfaces, components, condensate collectors, and drains.
2. Ensure that a suitable operative drainage system is in place prior to beginning wash-down procedures.
3. Clean evaporator coils, reheat coils, and other airstream components.
N. Air-Distribution Systems:
1. Create service openings in the HVAC system as necessary to accommodate cleaning.
2. Mechanically clean air-distribution systems specified to remove all visible contaminants, so that the systems are capable of passing the HVAC System Cleanliness Tests (see NADCA ACR).
O. Debris removed from the HVAC system shall be disposed of according to applicable Federal, state, and local requirements.
P. Mechanical Cleaning Methodology:
1. Source-Removal Cleaning Methods: The HVAC system shall be cleaned using sourceremoval mechanical cleaning methods designed to extract contaminants from within the HVAC system and to safely remove these contaminants from the facility. No cleaning method, or combination of methods, shall be used that could potentially damage components of the HVAC system or negatively alter the integrity of the system. a. Use continuously operating vacuum-collection devices to keep each section being cleaned under negative pressure.
b. Cleaning methods that require mechanical agitation devices to dislodge debris that is adhered to interior surfaces of HVAC system components shall be equipped to safely remove these devices. Cleaning methods shall not damage the integrity of HVAC system components or damage porous surface materials, such as duct and plenum liners.
2. Cleaning Mineral-Fiber Insulation Components:
250
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXISTING HVAC AIR DISTRIBUTION SYSTEM CLEANING 230130.52 - 6 a. Fibrous-glass thermal or acoustical insulation elements present in equipment or ductwork shall be thoroughly cleaned with HEPA vacuuming equipment while the HVAC system is under constant negative pressure and shall not be permitted to get wet according to NADCA ACR.
b. Cleaning methods used shall not cause damage to fibrous-glass components and will render the system capable of passing the HVAC System Cleanliness Tests (see NADCA ACR).
c. Fibrous materials that become wet shall be discarded and replaced.
Q. Application of Antimicrobial Treatment:
1. Apply antimicrobial agents and coatings if active fungal growth is determined by the IEP to be at Condition 2 or Condition 3 status according to IICRC S520, as analyzed by a laboratory accredited by AIHA-LAP with an EMLAP certificate, and with results interpreted by an IEP. Apply antimicrobial agents and coatings according to manufacturer's written recommendations and EPA registration listing after the removal of surface deposits and debris.
2. Apply antimicrobial treatments and coatings after the system is rendered clean.
3. Apply antimicrobial agents and coatings directly onto surfaces of interior ductwork.
4. Microbial remediation shall be performed by a qualified CMR and CMRS.
3.3 CLEANLINESS VERIFICATION
A. Verify cleanliness according to NADCA ACR, "Verification of HVAC System Cleanliness" Section.
B. Verify HVAC system cleanliness after mechanical cleaning and before applying any treatment or introducing any treatment-related substance to the HVAC system, including biocidal agents and coatings.
C. Surface-Cleaning Verification: Perform visual inspection for cleanliness. If no contaminants are evident through visual inspection, the HVAC system shall be considered clean. If visible contaminants are evident through visual inspection, those portions of the system where contaminants are visible shall be re-cleaned and subjected to re-inspection for cleanliness.
D. Prepare a written cleanliness verification report. At a minimum, include the following:
1. Written documentation of the success of the cleaning.
2. Site inspection reports, initialed by supervisor, including notation on areas of inspection, as verified through visual inspection.
3. Surface comparison test results if required.
4. Gravimetric analysis (nonporous surfaces only).
5. System areas found to be damaged.
3.4 RESTORATION
A. Restore and repair HVAC air-distribution equipment, ducts, plenums, and components according to NADCA ACR, "Restoration and Repair of Mechanical Systems" Section. 251
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
EXISTING HVAC AIR DISTRIBUTION SYSTEM CLEANING 230130.52 - 7 B. Restore service openings capable of future reopening. Comply with requirements in Section 233113 "Metal Ducts."
C. Replace fibrous-glass materials that cannot be restored by cleaning or resurfacing. Comply with requirements in Section 233113 "Metal Ducts" and Section 233116 "Nonmetal Ducts." D. Replace damaged insulation according to Section 230713 "Duct Insulation." E. Ensure that closures do not hinder or alter airflow.
F. New closure materials, including insulation, shall match opened materials and shall have removable closure panels fitted with gaskets and fasteners.
G. Restore manual volume dampers and air-directional mechanical devices inside the system to their marked position on completion of cleaning.
H. Measure air flows through air-distribution system.
I. Measure static-pressure differential across each coil.
3.5 PROJECT CLOSEOUT
A. Post-Project Report:
1. Post-cleaning laboratory results if any.
2. Post-cleaning photo images.
3. Post-cleaning verification summary.
B. Drawings:
1. Deviations of existing system from Owner's record drawings.
2. Location of service openings.
END OF SECTION 230130.52
252
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529 - 1 SECTION 230529 - HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Metal pipe hangers and supports.
2. Metal framing systems.
3. Thermal-hanger shield inserts.
4. Fastener systems.
5. Pipe stands.
6. Equipment stands.
7. Equipment supports.
B. Related Requirements:
1. Section 230548 "Vibration and Seismic Controls for HVAC" for vibration isolation devices.
2. Section 233113 "Metal Ducts" for duct hangers and supports.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Shop Drawings: Signed and sealed by a qualified professional engineer. Show fabrication and installation details and include calculations for the following; include Product Data for components:
1. Trapeze pipe hangers.
2. Metal framing systems.
3. Pipe stands.
4. Equipment supports.
C. Delegated-Design Submittal: For trapeze hangers indicated to comply with performance requirements and design criteria, including analysis data signed and sealed by the qualified professional engineer responsible for their preparation.
1. Detail fabrication and assembly of trapeze hangers.
2. Include design calculations for designing trapeze hangers. 253
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529 - 2
1.4 INFORMATIONAL SUBMITTALS
A. Welding certificates.
1.5 QUALITY ASSURANCE
A. Structural-Steel Welding Qualifications: Qualify procedures and personnel according to AWS D1.1/D1.1M, "Structural Welding Code - Steel."
B. Pipe Welding Qualifications: Qualify procedures and operators according to ASME Boiler and Pressure Vessel Code, Section IX.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Delegated Design: Engage a qualified professional engineer to design trapeze pipe hangers and equipment supports.
B. Structural Performance: Hangers and supports for HVAC piping and equipment shall withstand the effects of gravity loads and stresses within limits and under conditions indicated according to ASCE/SEI 7.
1. Design supports for multiple pipes, including pipe stands, capable of supporting combined weight of supported systems, system contents, and test water.
2. Design equipment supports capable of supporting combined operating weight of supported equipment and connected systems and components.
3. Design seismic-restraint hangers and supports for piping and equipment and obtain approval from authorities having jurisdiction.
2.2 METAL PIPE HANGERS AND SUPPORTS
A. Carbon-Steel Pipe Hangers and Supports:
1. Description: MSS SP-58, Types 1 through 58, factory-fabricated components.
2. Galvanized Metallic Coatings: Pregalvanized, hot-dip galvanized, or electro-galvanized.
3. Padded Hangers: Hanger with fiberglass or other pipe insulation pad or cushion to support bearing surface of piping.
4. Hanger Rods: Continuous-thread rod, nuts, and washer made of stainless steel.
B. Stainless Steel Pipe Hangers and Supports:
1. Description: MSS SP-58, Types 1 through 58, factory-fabricated components.
2. Padded Hangers: Hanger with fiberglass or other pipe insulation pad or cushion to support bearing surface of piping.
3. Hanger Rods: Continuous-thread rod, nuts, and washer made of stainless steel.
C. Copper Pipe and Tube Hangers:
254
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529 - 3
1. Description: MSS SP-58, Types 1 through 58, copper-plated steel, factory-fabricated components.
2. Hanger Rods: Continuous-thread rod, nuts, and washer made of copper-plated steel.
2.3 TRAPEZE PIPE HANGERS
Trapeze pipe hanger in "Description" Paragraph below requires calculating and detailing at each use.
A. Description: MSS SP-58, Type 59, shop- or field-fabricated pipe-support assembly made from structural carbon-steel shapes with MSS SP-58 carbon-steel hanger rods, nuts, saddles, and Ubolts.
2.4 THERMAL-HANGER SHIELD INSERTS
A. Insulation-Insert Material for Cold Piping: ASTM C552, Type II cellular glass with 100-psi (688-kPa) or ASTM C591, Type VI, Grade 1 polyisocyanurate with 125-psi (862-kPa) minimum compressive strength and vapor barrier.
B. For Trapeze or Clamped Systems: Insert and shield shall cover entire circumference of pipe.
C. For Clevis or Band Hangers: Insert and shield shall cover lower 180 degrees of pipe.
D. Insert Length: Extend 2 inches (50 mm) beyond sheet metal shield for piping operating below ambient air temperature.
2.5 FASTENER SYSTEMS
A. Powder-Actuated Fasteners: Threaded-steel stud, for use in hardened portland cement concrete with pull-out, tension, and shear capacities appropriate for supported loads and building materials where used.
B. Mechanical-Expansion Anchors: Insert-wedge-type anchors for use in hardened portland cement concrete; with pull-out, tension, and shear capacities appropriate for supported loads and building materials where used.
1. Indoor Applications: stainless steel.
2. Outdoor Applications: Stainless steel.
2.6 EQUIPMENT SUPPORTS
A. Description: Welded, shop- or field-fabricated equipment support made from structural carbonsteel shapes.
2.7 MATERIALS
A. Aluminum: ASTM B221 (ASTM B221M).
B. Carbon Steel: ASTM A1011/A1011M.
255
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529 - 4 C. Structural Steel: ASTM A36/A36M, carbon-steel plates, shapes, and bars; galvanized.
D. Stainless Steel: ASTM A240/A240M.
E. Threaded Rods: Continuously threaded. Zinc-plated or galvanized steel for indoor applications and stainless steel for outdoor applications. Mating nuts and washers of similar materials as rods.
F. Grout: ASTM C1107/C1107M, factory-mixed and -packaged, dry, hydraulic-cement, nonshrink and nonmetallic grout; suitable for interior and exterior applications.
1. Properties: Nonstaining, noncorrosive, and nongaseous.
2. Design Mix: 5000-psi (34.5-MPa), 28-day compressive strength.
PART 3 - EXECUTION
3.1 APPLICATION
A. Strength of Support Assemblies: Where not indicated, select sizes of components so strength will be adequate to carry present and future static loads within specified loading limits.
Minimum static design load used for strength determination shall be weight of supported components plus 200 lb (90 kg).
3.2 HANGER AND SUPPORT INSTALLATION
A. Metal Pipe-Hanger Installation: Comply with MSS SP-58. Install hangers, supports, clamps, and attachments as required to properly support piping from the building structure.
B. Metal Trapeze Pipe-Hanger Installation: Comply with MSS SP-58. Arrange for grouping of parallel runs of horizontal piping, and support together on field-fabricated trapeze pipe hangers.
1. Pipes of Various Sizes: Support together and space trapezes for smallest pipe size or install intermediate supports for smaller diameter pipes as specified for individual pipe hangers.
2. Field fabricate from ASTM A36/A36M, carbon-steel shapes selected for loads being supported. Weld steel according to AWS D1.1/D1.1M.
C. Thermal-Hanger Shield Installation: Install in pipe hanger or shield for insulated piping.
D. Fastener System Installation:
1. Install powder-actuated fasteners for use in lightweight concrete or concrete slabs less than 4 inches (100 mm) thick in concrete after concrete is placed and completely cured.
Use operators that are licensed by powder-actuated tool manufacturer. Install fasteners according to powder-actuated tool manufacturer's operating manual.
2. Install mechanical-expansion anchors in concrete after concrete is placed and completely cured. Install fasteners according to manufacturer's written instructions. 256
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529 - 5 E. Install hangers and supports complete with necessary attachments, inserts, bolts, rods, nuts, washers, and other accessories.
F. Equipment Support Installation: Fabricate from welded-structural-steel shapes.
G. Install hangers and supports to allow controlled thermal and seismic movement of piping systems, to permit freedom of movement between pipe anchors, and to facilitate action of expansion joints, expansion loops, expansion bends, and similar units.
H. Install lateral bracing with pipe hangers and supports to prevent swaying.
I. Install building attachments within concrete slabs or attach to structural steel. Install additional attachments at concentrated loads, including valves, flanges, and strainers, NPS 2-1/2 (DN 65) and larger and at changes in direction of piping. Install concrete inserts before concrete is placed; fasten inserts to forms and install reinforcing bars through openings at top of inserts.
J. Load Distribution: Install hangers and supports so that piping live and dead loads and stresses from movement will not be transmitted to connected equipment.
K. Pipe Slopes: Install hangers and supports to provide indicated pipe slopes and to not exceed maximum pipe deflections allowed by ASME B31.9 for building services piping.
L. Insulated Piping:
1. Attach clamps and spacers to piping.
a. Piping Operating above Ambient Air Temperature: Clamp may project through insulation.
b. Piping Operating below Ambient Air Temperature: Use thermal-hanger shield insert with clamp sized to match OD of insert.
c. Do not exceed pipe stress limits allowed by ASME B31.9 for building services piping.
2. Install MSS SP-58, Type 39, protection saddles if insulation without vapor barrier is indicated. Fill interior voids with insulation that matches adjoining insulation. a. Option: Thermal-hanger shield inserts may be used. Include steel weightdistribution plate for pipe NPS 4 (DN 100) and larger if pipe is installed on rollers.
3. Install MSS SP-58, Type 40, protective shields on cold piping with vapor barrier. Shields shall span an arc of 180 degrees.
a. Option: Thermal-hanger shield inserts may be used. Include steel weightdistribution plate for pipe NPS 4 (DN 100) and larger if pipe is installed on rollers.
4. Shield Dimensions for Pipe: Not less than the following:
a. NPS 1/4 to NPS 3-1/2 (DN 8 to DN 90): 12 inches (305 mm) long and 0.048 inch (1.22 mm) thick.
b. NPS 4 (DN 100): 12 inches (305 mm) long and 0.06 inch (1.52 mm) thick. 257
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529 - 6 c. NPS 5 and NPS 6 (DN 125 and DN 150): 18 inches (457 mm) long and 0.06 inch (1.52 mm) thick.
d. NPS 8 to NPS 14 (DN 200 to DN 350): 24 inches (610 mm) long and 0.075 inch (1.91 mm) thick.
e. NPS 16 to NPS 24 (DN 400 to DN 600): 24 inches (610 mm) long and 0.105 inch (2.67 mm) thick.
5. Pipes NPS 8 (DN 200) and Larger: Include wood or reinforced calcium-silicateinsulation inserts of length at least as long as protective shield.
6. Thermal-Hanger Shields: Install with insulation same thickness as piping insulation.
3.3 EQUIPMENT SUPPORTS
A. Fabricate structural-steel stands to suspend equipment from structure overhead or to support equipment above floor.
B. Grouting: Place grout under supports for equipment and make bearing surface smooth.
C. Provide lateral bracing, to prevent swaying, for equipment supports.
3.4 METAL FABRICATIONS
A. Cut, drill, and fit miscellaneous metal fabrications for trapeze pipe hangers and equipment supports.
B. Fit exposed connections together to form hairline joints. Field weld connections that cannot be shop welded because of shipping size limitations.
C. Field Welding: Comply with AWS D1.1/D1.1M procedures for shielded, metal arc welding; appearance and quality of welds; and methods used in correcting welding work; and with the following:
1. Use materials and methods that minimize distortion and develop strength and corrosion resistance of base metals.
2. Obtain fusion without undercut or overlap.
3. Remove welding flux immediately.
4. Finish welds at exposed connections so no roughness shows after finishing and so contours of welded surfaces match adjacent contours.
3.5 ADJUSTING
A. Hanger Adjustments: Adjust hangers to distribute loads equally on attachments and to achieve indicated slope of pipe.
B. Trim excess length of continuous-thread hanger and support rods to 1-1/2 inches (40 mm). 258
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529 - 7
3.6 PAINTING
A. Touchup: Clean field welds and abraded areas of shop paint. Paint exposed areas immediately after erecting hangers and supports. Use same materials as used for shop painting. Comply with SSPC-PA 1 requirements for touching up field-painted surfaces.
1. Apply paint by brush or spray to provide a minimum dry film thickness of 2.0 mils (0.05 mm).
B. Galvanized Surfaces: Clean welds, bolted connections, and abraded areas and apply galvanizing-repair paint to comply with ASTM A780/A780M.
3.7 HANGER AND SUPPORT SCHEDULE
A. Specific hanger and support requirements are in Sections specifying piping systems and equipment.
B. Comply with MSS SP-58 for pipe-hanger selections and applications that are not specified in piping system Sections.
C. Use hangers and supports with galvanized metallic coatings for piping and equipment that will not have field-applied finish.
D. Use nonmetallic coatings on attachments for electrolytic protection where attachments are in direct contact with copper tubing.
E. Use carbon-steel pipe hangers and supports, metal trapeze pipe hangers and attachments for general service applications.
F. Use copper-plated pipe hangers and copper or stainless steel attachments for copper piping and tubing.
G. Use padded hangers for piping that is subject to scratching.
H. Use thermal-hanger shield inserts for insulated piping and tubing.
I. Horizontal-Piping Hangers and Supports: Unless otherwise indicated and except as specified in piping system Sections, install the following types:
1. Adjustable, Steel Clevis Hangers (MSS Type 1): For suspension of noninsulated or insulated, stationary pipes NPS 1/2 to NPS 30 (DN 15 to DN 750).
2. Yoke-Type Pipe Clamps (MSS Type 2): For suspension of up to 1050 deg F (566 deg C), pipes NPS 4 to NPS 24 (DN 100 to DN 600), requiring up to 4 inches (100 mm) of insulation.
3. Carbon- or Alloy-Steel, Double-Bolt Pipe Clamps (MSS Type 3): For suspension of pipes NPS 3/4 to NPS 36 (DN 20 to DN 900), requiring clamp flexibility and up to 4 inches (100 mm) of insulation.
4. Steel Pipe Clamps (MSS Type 4): For suspension of cold and hot pipes NPS 1/2 to NPS 24 (DN 15 to DN 600) if little or no insulation is required. 259
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529 - 8
5. Pipe Hangers (MSS Type 5): For suspension of pipes NPS 1/2 to NPS 4 (DN 15 to DN 100), to allow off-center closure for hanger installation before pipe erection.
6. Adjustable, Swivel Split- or Solid-Ring Hangers (MSS Type 6): For suspension of noninsulated, stationary pipes NPS 3/4 to NPS 8 (DN 20 to DN 200).
7. Adjustable, Steel Band Hangers (MSS Type 7): For suspension of noninsulated, stationary pipes NPS 1/2 to NPS 8 (DN 15 to DN 200).
8. Adjustable Band Hangers (MSS Type 9): For suspension of noninsulated, stationary pipes NPS 1/2 to NPS 8 (DN 15 to DN 200).
9. Adjustable, Swivel-Ring Band Hangers (MSS Type 10): For suspension of noninsulated, stationary pipes NPS 1/2 to NPS 8 (DN 15 to DN 200).
10. Split Pipe Ring with or without Turnbuckle Hangers (MSS Type 11): For suspension of noninsulated, stationary pipes NPS 3/8 to NPS 8 (DN 10 to DN 200).
11. Extension Hinged or Two-Bolt Split Pipe Clamps (MSS Type 12): For suspension of noninsulated, stationary pipes NPS 3/8 to NPS 3 (DN 10 to DN 80).
12. U-Bolts (MSS Type 24): For support of heavy pipes NPS 1/2 to NPS 30 (DN 15 to DN 750).
13. Clips (MSS Type 26): For support of insulated pipes not subject to expansion or contraction.
14. Pipe Saddle Supports (MSS Type 36): For support of pipes NPS 4 to NPS 36 (DN 100 to DN 900), with steel-pipe base stanchion support and cast-iron floor flange or carbon-steel plate.
15. Pipe Stanchion Saddles (MSS Type 37): For support of pipes NPS 4 to NPS 36 (DN 100 to DN 900), with steel-pipe base stanchion support and cast-iron floor flange or carbonsteel plate, and with U-bolt to retain pipe.
16. Adjustable Pipe Saddle Supports (MSS Type 38): For stanchion-type support for pipes NPS 2-1/2 to NPS 36 (DN 65 to DN 900) if vertical adjustment is required, with steelpipe base stanchion support and cast-iron floor flange.
J. Vertical-Piping Clamps: Unless otherwise indicated and except as specified in piping system Sections, install the following types:
1. Extension Pipe or Riser Clamps (MSS Type 8): For support of pipe risers NPS 3/4 to NPS 24 (DN 24 to DN 600).
2. Carbon- or Alloy-Steel Riser Clamps (MSS Type 42): For support of pipe risers NPS 3/4 to NPS 24 (DN 20 to DN 600) if longer ends are required for riser clamps.
K. Hanger-Rod Attachments: Unless otherwise indicated and except as specified in piping system Sections, install the following types:
1. Steel Turnbuckles (MSS Type 13): For adjustment up to 6 inches (150 mm) for heavy loads.
2. Steel Clevises (MSS Type 14): For 120 to 450 deg F (49 to 232 deg C) piping installations.
3. Swivel Turnbuckles (MSS Type 15): For use with MSS Type 11, split pipe rings.
4. Malleable-Iron Sockets (MSS Type 16): For attaching hanger rods to various types of building attachments.
5. Steel Weldless Eye Nuts (MSS Type 17): For 120 to 450 deg F (49 to 232 deg C) piping installations.
L. Building Attachments: Unless otherwise indicated and except as specified in piping system Sections, install the following types:
260
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT 230529 - 9
1. Side-Beam Brackets (MSS Type 34): For sides of steel or wooden beams.
M. Saddles and Shields: Unless otherwise indicated and except as specified in piping system Sections, install the following types:
1. Steel-Pipe-Covering Protection Saddles (MSS Type 39): To fill interior voids with insulation that matches adjoining insulation.
2. Protection Shields (MSS Type 40): Of length recommended in writing by manufacturer to prevent crushing insulation.
3. Thermal-Hanger Shield Inserts: For supporting insulated pipe.
N. Spring Hangers and Supports: Unless otherwise indicated and except as specified in piping system Sections, install the following types:
1. Restraint-Control Devices (MSS Type 47): Where indicated to control piping movement.
2. Spring Cushions (MSS Type 48): For light loads if vertical movement does not exceed 1- 1/4 inches (32 mm).
3. Spring-Cushion Roll Hangers (MSS Type 49): For equipping Type 41, roll hanger with springs.
4. Spring Sway Braces (MSS Type 50): To retard sway, shock, vibration, or thermal expansion in piping systems.
5. Variable-Spring Hangers (MSS Type 51): Preset to indicated load and limit variability factor to 25 percent to allow expansion and contraction of piping system from hanger.
6. Variable-Spring Base Supports (MSS Type 52): Preset to indicated load and limit variability factor to 25 percent to allow expansion and contraction of piping system from base support.
7. Variable-Spring Trapeze Hangers (MSS Type 53): Preset to indicated load and limit variability factor to 25 percent to allow expansion and contraction of piping system from trapeze support.
8. Constant Supports: For critical piping stress and if necessary to avoid transfer of stress from one support to another support, critical terminal, or connected equipment. Include auxiliary stops for erection, hydrostatic test, and load-adjustment capability. These supports include the following types:
a. Horizontal (MSS Type 54): Mounted horizontally.
b. Vertical (MSS Type 55): Mounted vertically.
c. Trapeze (MSS Type 56): Two vertical-type supports and one trapeze member.
O. Comply with MSS SP-58 for trapeze pipe-hanger selections and applications that are not specified in piping system Sections.
P. Comply with MFMA-103 for metal framing system selections and applications that are not specified in piping system Sections.
Q. Use powder-actuated fasteners or mechanical-expansion anchors instead of building attachments where required in concrete construction.
END OF SECTION 230529
261
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
VIBRATION AND SEISMIC CONTROLS FOR HVAC 230548 - 1
SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Elastomeric isolation pads.
2. Snubbers.
1.2 DEFINITIONS
A. Designated Seismic System: An HVAC component that requires design in accordance with ASCE/SEI 7, Ch. 13, and for which the Component Importance Factor is greater than 1.0.
B. IBC: International Building Code.
1.3 ACTION SUBMITTALS
A. Product Data: For each type of product.
1. Include rated load, rated deflection, and overload capacity for each vibration isolation device.
2. Illustrate and indicate style, material, strength, fastening provision, and finish for each type and size of vibration isolation device and seismic restraint component.
3. Annotate types and sizes of seismic restraints and accessories, complete with listing markings or report numbers and load rating in tension and compression as evaluated by an agency acceptable to authorities having jurisdiction.
4. Annotate to indicate application of each product submitted and compliance with requirements.
5. Interlocking Snubbers: Include ratings for horizontal, vertical, and combined loads.
B. Shop Drawings:
1. Detail fabrication and assembly of equipment bases.
2. Vibration Isolation Base Details: Detail fabrication including anchorages and attachments to structure and to supported equipment. Include adjustable motor bases, rails, and frames for equipment mounting.
C. Delegated Design Submittals:
1. For each seismic-restraint device, including seismic-restrained mounting snubber, seismic restraint seismic-restraint accessory, and concrete anchor and insert that is required by this Section or is indicated on Drawings, submit the following:
262
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
VIBRATION AND SEISMIC CONTROLS FOR HVAC 230548 - 2
a. Concrete Anchors and Inserts: Include calculations showing anticipated seismic loads. Include certification that device is approved by an NRTL for seismic reinforcement use.
b. Seismic Design Calculations: Submit all input data and loading calculations prepared under "Seismic Design Calculations" Paragraph in "Performance Requirements" Article.
c. Qualified Professional Engineer: All designated-design submittals for seismicrestraint calculations are to be signed and sealed by qualified professional engineer responsible for their preparation.
2. Seismic-Restraint Detail Drawing:
a. Design Analysis: To support selection and arrangement of seismic restraints.
Include calculations of combined tensile and shear loads. b. Details: Indicate fabrication and arrangement. Detail attachments of restraints to restrained items and to the structure. Show attachment locations, methods, and spacings. Identify components, list their strengths, and indicate directions and values of forces transmitted to the structure during seismic events. Indicate association with vibration isolation devices.
3. All delegated design submittals for seismic-restraint detail Drawings are to be signed and sealed by qualified professional engineer responsible for their preparation.
4. Product Listing, Preapproval, and Evaluation Documentation: By an evaluation service member of an agency acceptable to authorities having jurisdiction, showing maximum ratings of restraint items and basis for approval (tests or calculations).
1.4 INFORMATIONAL SUBMITTALS
A. Coordination Drawings: Show coordination of vibration isolation device installation and seismic bracing for HVAC piping and equipment with other systems and equipment in the vicinity, including other supports and restraints, if any.
1.5 CLOSEOUT SUBMITTALS
1.6 QUALITY ASSURANCE
A. Seismic-Restraint Device Load Ratings: Devices to be tested and rated in accordance with applicable code requirements and authorities having jurisdiction. Devices to be listed by a nationally recognized third party that requires periodic follow-up inspections and has a listing directory available to the public. Provide third-party listing by one or more of the following: an agency acceptable to authorities having jurisdiction.
263
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
VIBRATION AND SEISMIC CONTROLS FOR HVAC 230548 - 3
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Delegated Design: Engage a qualified professional engineer to design seismic control system.
1. Seismic Performance: Equipment to withstand the effects of earthquake motions determined in accordance with ASCE/SEI 7-16.
B. Seismic Design Calculations:
1. Perform calculations to obtain force information necessary to properly select seismicrestraint devices, fasteners, and anchorage. Perform calculations using methods acceptable to applicable code authorities and as presented in ASCE/SEI 7-16. Where "ASCE/SEI 7" is used throughout this Section, it is to be understood that the edition referred to in this subparagraph is the edition intended as reference throughout the Section Text.
a. Data indicated below to be determined by Delegated Design Contractor must be obtained by Contractor and must be included in individual component submittal packages.
C. Consequential Damage: Provide additional seismic restraints for suspended HVAC components or anchorage of floor-, roof-, or wall-mounted HVAC components as indicated in ASCE/SEI 7- 16 so that failure of a non-essential or essential HVAC component will not cause failure of any other essential architectural, mechanical, or electrical building component.
D. Component Supports:
1. Load ratings, features, and applications of all reinforcement components must be based on testing standards of a nationally recognized testing agency.
2. All component support attachments must comply with force and displacement resistance requirements of ASCE/SEI 7-16 Section 13.6.
2.2 ELASTOMERIC ISOLATION PADS
A. Elastomeric Isolation Pads:
1. Source Limitations: Obtain elastomeric isolation pads from single manufacturer.
2. Fabrication: Single or multiple layers of sufficient durometer stiffness for uniform loading over pad area.
3. Size: Factory or field cut to match requirements of supported equipment.
4. Pad Material: Oil and water resistant with elastomeric properties. Neoprene rubber, silicone rubber, or other elastomeric material.
5. Surface Pattern: Smooth, ribbed, or waffle pattern.
a. Surface Pattern: Smooth, ribbed, or waffle pattern.
264
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
VIBRATION AND SEISMIC CONTROLS FOR HVAC 230548 - 4
2.3 SNUBBERS
A. Source Limitations: Obtain snubbers from single manufacturer.
B. Description: Factory fabricated using welded structural-steel shapes and plates, anchor bolts, and replaceable resilient isolation washers and bushings.
1. Post-Installed Concrete Anchor Bolts: Secure to concrete surface with post-installed concrete anchors. Anchors to be seismically prequalified in accordance with ACI 355.2 testing and designated in accordance with ACI 318-14 Ch. 17 for 2015 or 2018 IBC.
2. Preset Concrete Inserts: Seismically prequalified in accordance with ICC-ES AC446 testing.
3. Anchors in Masonry: Design in accordance with TMS 402.
4. Resilient Isolation Washers and Bushings: Oil- and water-resistant neoprene.
5. Resilient Cushion: Maximum 1/4-inch (6-mm) air gap, and minimum 1/4 inch (6 mm) thick.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine areas and equipment to receive vibration isolation and seismic devices for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.
B. Examine roughing-in of reinforcement and cast-in-place anchors to verify actual locations before installation.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 APPLICATIONS
A. Multiple Pipe Supports: Secure pipes to trapeze member with clamps approved for application by an agency acceptable to authorities having jurisdiction.
B. Hanger-Rod Stiffeners: Install where indicated or scheduled on Drawings to receive them and where required to prevent buckling of hanger rods due to seismic forces.
C. Strength of Support and Seismic-Restraint Assemblies: Where not indicated, select sizes of components so strength is adequate to carry present and future static and seismic loads within specified loading limits.
3.3 INSTALLATION OF VIBRATION-CONTROL AND SEISMIC-RESTRAINT DEVICES A. Provide vibration-control devices for systems and equipment where indicated in Equipment Schedules or Vibration-Control Devices Schedules, where indicated on Drawings, or where Specifications indicate they are to be installed on specific equipment and systems. 265
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
VIBRATION AND SEISMIC CONTROLS FOR HVAC 230548 - 5
B. Provide seismic-restraint control devices for systems and equipment where indicated in Equipment Schedules or Seismic-Restraint Devices Schedules, where indicated on Drawings, where Specifications indicate they are to be installed on specific equipment and systems, and where required by applicable codes.
C. Coordinate location of embedded connection hardware with supported equipment attachment and mounting points and with requirements for concrete reinforcement and formwork specified in Section 033000 "Cast-in-Place Concrete."
D. Installation of vibration isolators must not cause any change of position of equipment, piping, or ductwork resulting in stresses or misalignment.
E. Equipment Restraints:
1. Install seismic snubbers on HVAC equipment mounted on vibration isolators. Locate snubbers as close as possible to vibration isolators and bolt to equipment base and supporting structure.
2. Install resilient bolt isolation washers on equipment anchor bolts where clearance between anchor and adjacent surface exceeds 0.125 inch (3.2 mm).
3. Install seismic-restraint devices using methods approved by an agency acceptable to authorities having jurisdiction that provides required submittals for component.
F. Piping Restraints:
1. Comply with requirements in MSS SP-127.
2. Space lateral supports a maximum of 40 feet (12 m) o.c., and longitudinal supports a maximum of 80 feet (24 m) o.c.
3. Brace a change of direction longer than 12 feet (3.7 m).
G. Ductwork Restraints:
1. Install ducts with hangers and braces designed to support the duct and to restrain against seismic forces required by applicable building codes. Comply with SMACNA's "Seismic Restraint Manual: Guidelines for Mechanical Systems."
2. Space lateral supports a maximum of 40 feet (12 m) o.c., and longitudinal supports a maximum of 80 feet (24 m) o.c.
3. Brace a change of direction longer than 12 feet (3.7 m).
4. Select seismic-restraint devices with capacities adequate to carry static and seismic loads.
5. Install cable restraints on ducts that are suspended with vibration isolators.
H. Install seismic-load-restraint cables so they do not bend across edges of adjacent equipment or building structure.
I. Install seismic-restraint devices using methods approved by an agency acceptable to authorities having jurisdiction that provides required submittals for component.
J. Install bushing assemblies for anchor bolts for floor-mounted equipment, arranged to provide resilient media between anchor bolt and mounting hole in concrete base.
K. Install bushing assemblies for mounting bolts for wall-mounted equipment, arranged to provide resilient media where equipment or equipment-mounting channels are attached to wall. 266
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
VIBRATION AND SEISMIC CONTROLS FOR HVAC 230548 - 6
L. Attachment to Structure: If specific attachment is not indicated, anchor bracing to structure at flanges of beams, at upper truss chords of bar joists, or at concrete members.
M. Mechanical Anchor Bolts:
1. Identify position of reinforcing steel and other embedded items prior to drilling holes for anchors. Do not damage existing reinforcing or embedded items during coring or drilling.
Notify structural engineer if reinforcing steel or other embedded items are encountered during drilling. Locate and avoid prestressed tendons, electrical and telecommunications conduit, and gas lines.
2. Do not drill holes in concrete or masonry until concrete, mortar, or grout has achieved full design strength.
3. Wedge-Type Anchor Bolts: Protect threads from damage during anchor installation.
Heavy-duty sleeve anchors to be installed with sleeve fully engaged in the structural element to which anchor is to be fastened.
4. Adhesive-Type Anchor Bolts: Clean holes to remove loose material and drilling dust prior to installation of adhesive. Place adhesive in holes proceeding from the bottom of the hole and progressing toward the surface in such a manner as to avoid introduction of air pockets in the adhesive.
5. Set anchors to manufacturer's recommended torque, using a torque wrench.
6. Install zinc-coated steel anchors for interior and stainless-steel anchors for exterior applications.
3.4 ADJUSTING
A. Adjust isolators after system is at operating weight.
B. Adjust limit stops on restrained-spring isolators to mount equipment at normal operating height.
After equipment installation is complete, adjust limit stops so they are out of contact during normal operation.
3.5 FIELD QUALITY CONTROL
A. Testing Agency: Engage a qualified testing agency to perform tests and inspections.
B. Manufacturer's Field Service: Engage a factory-authorized service representative to test and inspect components, assemblies, and equipment installations, including connections.
C. Tests and Inspections:
1. Perform tests and inspections with the assistance of a factory-authorized service representative.
2. Provide evidence of recent calibration of test equipment by a testing agency acceptable to authorities having jurisdiction.
3. Schedule test with Owner, through Architect, before connecting anchorage device to restrained component (unless postconnection testing has been approved), and with at least seven days' advance notice.
4. Obtain Architect's approval before transmitting test loads to structure. Provide temporary load-spreading members.
267
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
VIBRATION AND SEISMIC CONTROLS FOR HVAC 230548 - 7
5. Test no fewer than four of each type and size of installed anchors and fasteners selected by Architect.
6. Test to 90 percent of rated proof load of device.
7. Measure isolator restraint clearance.
8. Measure isolator deflection.
9. Verify snubber minimum clearances.
10. Test and adjust restrained-air-spring isolator controls and safeties.
D. Remove and replace malfunctioning units and retest as specified above.
E. Units will be considered defective if they do not pass tests and inspections.
F. Prepare test and inspection reports.
END OF SECTION 230548
268
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553 - 1 SECTION 230553 - IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Equipment labels.
2. Warning signs and labels.
3. Warning tape.
4. Pipe labels.
5. Duct labels.
6. Warning tags.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product.
B. Samples: For color, letter style, and graphic representation required for each identification material and device.
C. Equipment-Label Schedule: Include a listing of all equipment to be labeled with the proposed content for each label.
D. Valve Schedules: Provide for each piping system. Include in operation and maintenance manuals.
PART 2 - PRODUCTS
2.1 EQUIPMENT LABELS
A. Metal Labels for Equipment:
1. Material and Thickness: stainless steel, 0.025-inch (0.64-mm) minimum thickness, with predrilled or stamped holes for attachment hardware.
2. Letter and Background Color: As indicated for specific application under Part 3.
3. Minimum Label Size: Length and width vary for required label content, but not less than 2-1/2 by 3/4 inch (64 by 19 mm).
4. Minimum Letter Size: 1/4 inch (6.4 mm) for name of units if viewing distance is less than 24 inches (600 mm), 1/2 inch (13 mm) for viewing distances of up to 72 inches (1830 mm), and proportionately larger lettering for greater viewing distances. Include secondary lettering two-thirds to three-fourths the size of principal lettering.
5. Fasteners: Stainless steel rivets or self-tapping screws.
6. Adhesive: Contact-type permanent adhesive, compatible with label and with substrate. 269
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553 - 2
2.2 WARNING SIGNS AND LABELS
A. Material and Thickness: Multilayer, multicolor, plastic labels for mechanical engraving, 1/16 inch (1.6 mm) thick, with predrilled holes for attachment hardware.
B. Letter and Background Color: As indicated for specific application under Part 3.
C. Minimum Label Size: Length and width vary for required label content, but not less than 2-1/2 by 3/4 inch (64 by 19 mm).
D. Minimum Letter Size: 1/4 inch (6.4 mm) for name of units if viewing distance is less than 24 inches (600 mm), 1/2 inch (13 mm) for viewing distances of up to 72 inches (1830 mm), and proportionately larger lettering for greater viewing distances. Include secondary lettering twothirds to three-fourths the size of principal lettering.
E. Fasteners: Stainless steel rivets or self-taping screws.
F. Adhesive: Contact-type permanent adhesive, compatible with label and with substrate.
G. Arc-Flash Warning Signs: Provide arc-flash warning signs in locations and with content in accordance with requirements of OSHA and NFPA70E and other applicable codes and standards.
H. Label Content: Include caution and warning information plus emergency notification instructions.
2.3 WARNING TAPE
A. Material: Vinyl.
B. Minimum Thickness: 0.005 inch (0.12 mm).
C. Letter, Pattern, and Background Color: As indicated for specific application under Part 3.
D. Waterproof Adhesive Backing: Suitable for indoor or outdoor use.
E. Maximum Temperature: 160 deg F (70 deg C).
F. Minimum Width: 2 inches (50 mm).
2.4 PIPE LABELS
A. General Requirements for Manufactured Pipe Labels: Preprinted, color coded, with lettering indicating service and showing flow direction in accordance with ASME A13.1.
B. Letter and Background Color: As indicated for specific application under Part 3.
C. Pretensioned Pipe Labels: Precoiled, semirigid plastic formed to partially cover circumference of pipe and to attach to pipe without fasteners or adhesive. 270
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553 - 3 D. Self-Adhesive Pipe Labels: Printed plastic with contact-type, permanent-adhesive backing.
E. Pipe Label Contents: Include identification of piping service using same designations or abbreviations as used on Drawings. Also include:
1. Pipe size.
2. Flow-Direction Arrows: Include flow-direction arrows on main distribution piping.
Arrows may be either integral with label or applied separately.
2.5 DUCT LABELS
A. Material and Thickness: Multilayer, multicolor, plastic labels for mechanical engraving, 1/16 inch (1.6 mm) thick, and having predrilled holes for attachment hardware.
B. Letter and Background Color: As indicated for specific application under Part 3.
C. Maximum Temperature: Able to withstand temperatures up to 160 deg F (71 deg C).
D. Minimum Label Size: Length and width vary for required label content, but not less than 2-1/2 by 3/4 inch (64 by 19 mm).
E. Minimum Letter Size: 1/4 inch (6.4 mm) for name of units if viewing distance is less than 24 inches (600 mm), 1/2 inch (13 mm) for viewing distances of up to 72 inches (1830 mm), and proportionately larger lettering for greater viewing distances. Include secondary lettering twothirds to three-fourths the size of principal lettering.
F. Fasteners: Stainless steel rivets or self-tapping screws.
G. Adhesive: Contact-type permanent adhesive, compatible with label and with substrate.
H. Duct Label Contents: Include identification of duct service using same designations or abbreviations as used on Drawings. Also include the following:
1. Duct size.
2. Flow-Direction Arrows: Include flow-direction arrows on main distribution ducts.
Arrows may be either integral with label or may be applied separately.
2.6 WARNING TAGS
A. Description: Preprinted accident-prevention tags of plasticized card stock with matte finish suitable for writing.
1. Size: Approximately 4 by 7 inches (100 by 178 mm).
2. Fasteners: Brass grommet and wire.
3. Nomenclature: Large-size primary caption, such as "DANGER," "CAUTION," or "DO NOT OPERATE."
4. Letter and Background Color: As indicated for specific application under Part 3. 271
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553 - 4 PART 3 - EXECUTION
3.1 PREPARATION
A. Clean piping and equipment surfaces of incompatible primers, paints, and encapsulants, as well as dirt, oil, grease, release agents, and other substances that could impair bond of identification devices.
3.2 INSTALLATION, GENERAL REQUIREMENTS
A. Coordinate installation of identifying devices with completion of covering and painting of surfaces where devices are to be applied.
B. Coordinate installation of identifying devices with locations of access panels and doors.
C. Install identifying devices before installing acoustical ceilings and similar concealment.
D. Locate identifying devices so that they are readily visible from the point of normal approach.
3.3 INSTALLATION OF EQUIPMENT LABELS, WARNING SIGNS, AND LABELS A. Permanently fasten labels on each item of mechanical equipment.
B. Sign and Label Colors:
1. White letters on an ANSI Z535.1 safety-blue background.
C. Locate equipment labels where accessible and visible.
D. Arc-Flash Warning Signs: Provide arc-flash warning signs on electrical disconnects and other equipment where arc-flash hazard exists, as indicated on Drawings, and in accordance with requirements of OSHA and NFPA 70E, and other applicable codes and standards.
3.4 INSTALLATION OF WARNING TAPE
A. Warning Tape Color and Pattern: Yellow background with black diagonal stripes.
B. Install warning tape on pipes and ducts, with cross-designated walkways providing less than 6 ft. (2 m) of clearance.
C. Locate tape so as to be readily visible from the point of normal approach.
3.5 INSTALLATION OF PIPE LABELS
A. Install pipe labels showing service and flow direction with permanent adhesive on pipes. 272
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
IDENTIFICATION FOR HVAC PIPING AND EQUIPMENT 230553 - 5 B. Pipe-Label Locations: Locate pipe labels where piping is exposed or above accessible ceilings in finished spaces; machine rooms; accessible maintenance spaces such as shafts, tunnels, and plenums; and exterior exposed locations as follows:
1. Within 3 ft. (1 m) of each valve and control device.
2. At access doors, manholes, and similar access points that permit view of concealed piping.
3. Within 3 ft. (1 m) of equipment items and other points of origination and termination.
4. Spaced at maximum intervals of along each run. Reduce intervals to 10 ft. (3.0 m in areas of congested piping, ductwork, and equipment.
C. Do not apply plastic pipe labels or plastic tapes directly to bare pipes conveying fluids at temperatures of 125 deg F (52 deg C) or higher. Where these pipes are to remain uninsulated, use a short section of insulation or use stenciled labels.
D. Flow-Direction Arrows: Use arrows to indicate direction of flow in pipes, including pipes where flow is allowed in both directions.
E. Pipe-Label Color Schedule:
1. Refrigerant Piping: White letters on an ANSI Z535.1 safety-blue background.
2. Toxic and Corrosive Fluids: Black letters on an ANSI Z535.1 safety-orange background.
3. Flammable Fluids: Black letters on an ANSI Z535.1 safety-yellow background.
4. Combustible Fluids: White letters on an ANSI Z535.1 safety-brown background.
3.6 INSTALLATION OF DUCT LABELS
A. Install plastic-laminated self-adhesive duct labels showing service and flow direction with permanent adhesive on air ducts.
1. Provide labels in the following color codes:
a. For air supply ducts: White letters on blue background. b. For air return ducts: White letters on blue background. c. For exhaust-, outside-, relief-, return-, and mixed-air ducts: White letters on blue background.
B. Locate label near each point where ducts enter into and exit from concealed spaces and at maximum intervals of 10 ft. (6 m) where exposed or are concealed by removable ceiling system.
3.7 INSTALLATION OF WARNING TAGS
A. Warning Tag Color: Black letters on an ANSI Z535.1 safety-yellow background.
B. Attach warning tags, with proper message, to equipment and other items where scheduled.
END OF SECTION 230553
273
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TESTING, ADJUSTING, AND BALANCING FOR HVAC 230593 - 1
SECTION 230593 - TESTING, ADJUSTING, AND BALANCING FOR HVAC PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Testing, Adjusting, and Balancing of Air Systems:
a. Variable-air-volume systems.
2. Testing, adjusting, and balancing of equipment.
3. Duct leakage tests verification.
4. HVAC-control system verification.
1.2 DEFINITIONS
A. AABC: Associated Air Balance Council.
B. NEBB: National Environmental Balancing Bureau.
C. TAB: Testing, adjusting, and balancing.
D. TABB: Testing, Adjusting, and Balancing Bureau.
E. TAB Specialist: An independent entity meeting qualifications to perform TAB work.
1.3 INFORMATIONAL SUBMITTALS
A. Qualification Data: Within 30 days of Contractor's Notice to Proceed, submit documentation that the TAB specialist and this Project's TAB team members meet the qualifications specified in "Quality Assurance" Article.
B. Contract Documents Examination Report: Within 30 days of Contractor's Notice to Proceed, submit the Contract Documents review report, as specified in Part 3.
C. Strategies and Procedures Plan: Within 30 days of Contractor's Notice to Proceed, submit TAB strategies and step-by-step procedures, as specified in "Preparation" Article.
D. System Readiness Checklists: Within 30 days of Contractor's Notice to Proceed, submit system readiness checklists, as specified in "Preparation" Article.
E. Examination Report: Submit a summary report of the examination review required in "Examination" Article.
F. Certified TAB reports.
G. Sample report forms.
274
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TESTING, ADJUSTING, AND BALANCING FOR HVAC 230593 - 2
H. Instrument calibration reports, to include the following:
1. Instrument type and make.
2. Serial number.
3. Application.
4. Dates of use.
5. Dates of calibration.
1.4 QUALITY ASSURANCE
A. TAB Specialists Qualifications, Certified by AABC:
1. TAB Field Supervisor: Employee of the TAB specialist and certified by AABC.
2. TAB Technician: Employee of the TAB specialist and certified by AABC.
B. TAB Specialists Qualifications, Certified by TABB:
1. TAB Field Supervisor: Employee of the TAB specialist and certified by TABB.
2. TAB Technician: Employee of the TAB specialist and certified by TABB.
C. Instrumentation Type, Quantity, Accuracy, and Calibration: Comply with requirements in ASHRAE 111, Section 4, "Instrumentation."
D. ASHRAE/IES 90.1 Compliance: Applicable requirements in ASHRAE/IES 90.1, Section 6.7.2.3 - "System Balancing."
E. Code and AHJ Compliance: TAB is required to comply with governing codes and requirements of authorities having jurisdiction.
1.5 FIELD CONDITIONS
A. Full Owner Occupancy: Owner will occupy the site and existing building during entire TAB period. Cooperate with Owner during TAB operations to minimize conflicts with Owner's operations.
B. Partial Owner Occupancy: Owner may occupy completed areas of building before Substantial Completion. Cooperate with Owner during TAB operations to minimize conflicts with Owner's operations.
PART 2 - PRODUCTS (Not Applicable)
PART 3 - EXECUTION
3.1 TAB SPECIALISTS
1. Engage a qualified TAB specialist to perform test and inspections. 275
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TESTING, ADJUSTING, AND BALANCING FOR HVAC 230593 - 3
3.2 EXAMINATION
A. Examine the Contract Documents to become familiar with Project requirements and to discover conditions in systems designs that may preclude proper TAB of systems and equipment.
B. Examine the approved submittals for HVAC systems and equipment.
C. Examine design data, including HVAC system descriptions, statements of design assumptions for environmental conditions and systems output, and statements of philosophies and assumptions about HVAC system and equipment controls.
D. Examine equipment performance data, including fan and pump curves.
1. Relate performance data to Project conditions and requirements, including system effects that can create undesired or unpredicted conditions that cause reduced capacities in all or part of a system.
2. Calculate system-effect factors to reduce performance ratings of HVAC equipment when installed under conditions different from the conditions used to rate equipment performance. To calculate system effects for air systems, use tables and charts found in AMCA 201, "Fans and Systems," or in SMACNA's "HVAC Systems - Duct Design." Compare results with the design data and installed conditions.
E. Examine system and equipment installations and verify that field quality-control testing, cleaning, and adjusting specified in individual Sections have been performed.
F. Examine test reports specified in individual system and equipment Sections.
G. Examine HVAC equipment and verify that bearings are greased, belts are aligned and tight, filters are clean, and equipment with functioning controls is ready for operation.
H. Examine control valves for proper installation for their intended function of isolating, throttling, diverting, or mixing fluid flows.
I. Examine heat-transfer coils for correct piping connections and for clean and straight fins.
J. Examine system pumps to ensure absence of entrained air in the suction piping.
K. Examine operating safety interlocks and controls on HVAC equipment.
L. Examine control dampers for proper installation for their intended function of isolating, throttling, diverting, or mixing air flows.
M. Report deficiencies discovered before and during performance of TAB procedures. Observe and record system reactions to changes in conditions. Record default set points if different from indicated values.
3.3 PREPARATION
A. Prepare a TAB plan that includes the following:
276
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TESTING, ADJUSTING, AND BALANCING FOR HVAC 230593 - 4
1. Equipment and systems to be tested.
2. Strategies and step-by-step procedures for balancing the systems.
3. Instrumentation to be used.
4. Sample forms with specific identification for all equipment.
B. Perform system-readiness checks of HVAC systems and equipment to verify system readiness for TAB work. Include, at a minimum, the following:
1. Airside:
a. Verify that leakage and pressure tests on air distribution systems have been satisfactorily completed.
b. Duct systems are complete with terminals installed.
c. Volume, smoke, and fire dampers are open and functional. d. Clean filters are installed.
e. Fans are operating, free of vibration, and rotating in correct direction. f. Variable-frequency controllers' startup is complete and safeties are verified. g. Automatic temperature-control systems are operational. h. Ceilings are installed.
i. Windows and doors are installed.
j. Suitable access to balancing devices and equipment is provided.
3.4 GENERAL PROCEDURES FOR TESTING AND BALANCING
A. Perform testing and balancing procedures on each system in accordance with the procedures contained in NEBB's "Procedural Standards for Testing, Adjusting, and Balancing of Environmental Systems" and in this Section.
B. Cut insulation, ducts, pipes, and equipment casings for installation of test probes to the minimum extent necessary for TAB procedures.
1. After testing and balancing, install test ports and duct access doors that comply with requirements in Section 233300 "Air Duct Accessories."
2. Where holes for probes are required in piping or hydronic equipment, install pressure and temperature test plugs to seal systems.
3. Install and join new insulation that matches removed materials. Restore insulation, coverings, vapor barrier, and finish in accordance with Section 230713 "Duct Insulation," and Section 230719 "HVAC Piping Insulation."
C. Mark equipment and balancing devices, including damper-control positions, valve position indicators, fan-speed-control levers, and similar controls and devices, with paint or other suitable, permanent identification material to show final settings.
D. Take and report testing and balancing measurements in inch-pound (IP) and metric (SI) units.
3.5 TESTING, ADJUSTING, AND BALANCING OF HVAC EQUIPMENT A. Test, adjust, and balance HVAC equipment indicated on Drawings, including, but not limited to, the following:
1. Furnaces.
277
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TESTING, ADJUSTING, AND BALANCING FOR HVAC 230593 - 5
2. Condensing units.
3. Coils.
3.6 GENERAL PROCEDURES FOR BALANCING AIR SYSTEMS
A. Prepare test reports for both fans and outlets. Obtain manufacturer's outlet factors and recommended testing procedures. Crosscheck the summation of required outlet volumes with required fan volumes.
B. Prepare schematic diagrams of systems' Record drawings duct layouts.
C. For variable-air-volume systems, develop a plan to simulate diversity.
D. Determine the best locations in main and branch ducts for accurate duct-airflow measurements.
E. Check airflow patterns from the outdoor-air louvers and dampers and the return- and exhaust-air dampers through the supply-fan discharge and mixing dampers.
F. Locate start-stop and disconnect switches, electrical interlocks, and motor starters.
G. Verify that motor starters are equipped with properly sized thermal protection.
H. Check dampers for proper position to achieve desired airflow path.
I. Check for airflow blockages.
J. Check condensate drains for proper connections and functioning.
K. Check for proper sealing of air-handling-unit components.
3.7 PROCEDURES FOR VARIABLE-AIR-VOLUME SYSTEMS
A. Adjust the variable-air-volume systems as follows:
1. Verify that the system static pressure sensor is located two-thirds of the distance down the duct from the fan discharge.
2. Verify that the system is under static pressure control.
3. Select the terminal unit that is most critical to the supply-fan airflow. Measure inlet static pressure, and adjust system static pressure control set point so the entering static pressure for the critical terminal unit is not less than the sum of the terminal-unit manufacturer's recommended minimum inlet static pressure plus the static pressure needed to overcome terminal-unit discharge system losses.
4. Calibrate and balance each terminal unit for maximum and minimum design airflow as follows:
a. Adjust controls so that terminal is calling for maximum airflow. Some controllers require starting with minimum airflow. Verify calibration procedure for specific project.
278
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TESTING, ADJUSTING, AND BALANCING FOR HVAC 230593 - 6
b. Measure airflow and adjust calibration factor as required for design maximum airflow. Record calibration factor.
c. When maximum airflow is correct, balance the air outlets downstream from terminal units.
d. Adjust controls so that terminal is calling for minimum airflow. e. Measure airflow and adjust calibration factor as required for design minimum airflow. Record calibration factor. If no minimum calibration is available, note any deviation from design airflow.
f. On constant volume terminals, in critical areas where room pressure is to be maintained, verify that the airflow remains constant over the full range of full cooling to full heating. Note any deviation from design airflow or room pressure.
5. After terminals have been calibrated and balanced, test and adjust system for total airflow. Adjust fans to deliver total design airflows within the maximum allowable fan speed listed by fan manufacturer.
a. Set outside-air, return-air, and relief-air dampers for proper position that simulates minimum outdoor-air conditions.
b. Set terminals for maximum airflow. If system design includes diversity, adjust terminals for maximum and minimum airflow, so that connected total matches fan selection and simulates actual load in the building.
c. Where duct conditions allow, measure airflow by main Pitot-tube traverse. If necessary, perform multiple Pitot-tube traverses close to the fan and prior to any outlets, to obtain total airflow.
d. Where duct conditions are unsuitable for Pitot-tube traverse measurements, a coil traverse may be acceptable.
6. Measure fan static pressures as follows:
a. Measure static pressure directly at the fan outlet or through the flexible connection. b. Measure static pressure directly at the fan inlet or through the flexible connection. c. Measure static pressure across each component that makes up the air-handling system.
d. Report any artificial loading of filters at the time static pressures are measured.
7. Set final return and outside airflow to the fan while operating at maximum return airflow and minimum outdoor airflow.
a. Balance the return-air ducts and inlets.
b. Verify that terminal units are meeting design airflow under system maximum flow.
8. Re-measure the inlet static pressure at the most critical terminal unit, and adjust the system static pressure set point to the most energy-efficient set point to maintain the optimum system static pressure. Record set point and give to controls Contractor.
9. Verify final system conditions as follows:
a. Re-measure and confirm that minimum outdoor, return, and relief airflows are within design. Readjust to match design if necessary.
b. Re-measure and confirm that total airflow is within design. c. Re-measure final fan operating data, speed, volts, amps, and static profile. d. Mark final settings.
279
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TESTING, ADJUSTING, AND BALANCING FOR HVAC 230593 - 7
e. Test system in economizer mode. Verify proper operation and adjust if necessary.
Measure and record all operating data.
f. Verify tracking between supply and return fans.
3.8 DUCT LEAKAGE TESTS
A. Witness the duct leakage testing performed by Installer.
B. Verify that proper test methods are used and that leakage rates are within specified limits.
C. Report deficiencies observed.
3.9 HVAC CONTROLS VERIFICATION
A. In conjunction with system balancing, perform the following:
1. Verify HVAC control system is operating within the design limitations.
2. Confirm that the sequences of operation are in compliance with Contract Documents.
3. Verify that controllers are calibrated and function as intended.
4. Verify that controller set points are as indicated.
5. Verify the operation of lockout or interlock systems.
6. Verify the operation of valve and damper actuators.
7. Verify that controlled devices are properly installed and connected to correct controller.
8. Verify that controlled devices travel freely and are in position indicated by controller:
open, closed, or modulating.
9. Verify location and installation of sensors to ensure that they sense only intended temperature, humidity, or pressure.
B. Reporting: Include a summary of verifications performed, remaining deficiencies, and variations from indicated conditions.
3.10 PROGRESS REPORTING
A. Initial Construction-Phase Report: Based on examination of the Contract Documents as specified in "Examination" Article, prepare a report on the adequacy of design for systembalancing devices. Recommend changes and additions to system-balancing devices, to facilitate proper performance measuring and balancing. Recommend changes and additions to HVAC systems and general construction to allow access for performance-measuring and -balancing devices.
B. Status Reports: Prepare weekly progress reports to describe completed procedures, procedures in progress, and scheduled procedures. Include a list of deficiencies and problems found in systems being tested and balanced. Prepare a separate report for each system and each building floor for systems serving multiple floors.
280
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TESTING, ADJUSTING, AND BALANCING FOR HVAC 230593 - 8
3.11 FINAL REPORT
A. General: Prepare a certified written report; tabulate and divide the report into separate sections for tested systems and balanced systems.
1. Include a certification sheet at the front of the report's binder, signed and sealed by the certified testing and balancing engineer.
2. Include a list of instruments used for procedures, along with proof of calibration.
3. Certify validity and accuracy of field data.
B. Final Report Contents: In addition to certified field-report data, include the following:
1. Pump curves.
2. Fan curves.
3. Manufacturers' test data.
4. Field test reports prepared by system and equipment installers.
5. Other information relative to equipment performance; do not include Shop Drawings and Product Data.
C. General Report Data: In addition to form titles and entries, include the following data:
1. Title page.
2. Name and address of the TAB specialist.
3. Project name.
4. Project location.
5. Architect's name and address.
6. Engineer's name and address.
7. Contractor's name and address.
8. Report date.
9. Signature of TAB supervisor who certifies the report.
10. Table of Contents with the total number of pages defined for each section of the report.
Number each page in the report.
11. Summary of contents, including the following:
a. Indicated versus final performance.
b. Notable characteristics of systems.
c. Description of system operation sequence if it varies from the Contract Documents.
12. Nomenclature sheets for each item of equipment.
13. Data for terminal units, including manufacturer's name, type, size, and fittings.
14. Notes to explain why certain final data in the body of reports vary from indicated values.
15. Test conditions for fans performance forms, including the following:
a. Settings for outdoor-, return-, and exhaust-air dampers. b. Conditions of filters.
c. Cooling coil, wet- and dry-bulb conditions.
d.
e. Fan drive settings, including settings and percentage of maximum pitch diameter. f. Settings for pressure controller(s).
g. Other system operating conditions that affect performance. 281
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TESTING, ADJUSTING, AND BALANCING FOR HVAC 230593 - 9
16. Test conditions for pump performance forms, including the following:
a. Variable-frequency controller settings for variable-flow hydronic systems. b. Settings for pressure controller(s).
c. Other system operating conditions that affect performance.
D. Apparatus-Coil Test Reports:
1. Coil Data:
a. System identification.
b. Location.
c. Coil type.
d. Number of rows.
e. Fin spacing in fins per inch (mm) o.c.
f. Make and model number.
g. Face area in sq. ft. (sq. m).
h. Tube size in NPS (DN).
i. Tube and fin materials.
j. Circuiting arrangement.
2. Test Data (Indicated and Actual Values):
a. Airflow rate in cfm (L/s).
b. Average face velocity in fpm (m/s).
c. Air pressure drop in inches wg (Pa).
d. Outdoor-air, wet- and dry-bulb temperatures in deg F (deg C). e. Return-air, wet- and dry-bulb temperatures in deg F (deg C). f. Entering-air, wet- and dry-bulb temperatures in deg F (deg C). g. Leaving-air, wet- and dry-bulb temperatures in deg F (deg C). h. Refrigerant expansion valve and refrigerant types.
i. Refrigerant suction pressure in psig (kPa).
j. Refrigerant suction temperature in deg F (deg C).
E. Instrument Calibration Reports:
1. Report Data:
a. Instrument type and make.
b. Serial number.
c. Application.
d. Dates of use.
e. Dates of calibration.
3.12 VERIFICATION OF TAB REPORT
A. The TAB specialist's test and balance engineer shall conduct the inspection in the presence of Construction Manager.
282
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TESTING, ADJUSTING, AND BALANCING FOR HVAC 230593 - 10
B. Commissioning Authority shall randomly select measurements, documented in the final report, to be rechecked. Rechecking shall be limited to the lesser of either 10 percent of the total measurements recorded or the extent of measurements that can be accomplished in a normal 8- hour business day.
C. If rechecks yield measurements that differ from the measurements documented in the final report by more than the tolerances allowed, the measurements shall be noted as "FAILED." D. If the number of "FAILED" measurements is greater than 10 percent of the total measurements checked during the final inspection, the TAB shall be considered incomplete and shall be rejected.
E. If recheck measurements find the number of failed measurements noncompliant with requirements indicated, proceed as follows:
1. TAB specialists shall recheck all measurements and make adjustments. Revise the final report and balancing device settings to include all changes; resubmit the final report and request a second final inspection. All changes shall be tracked to show changes made to previous report.
2. If the second final inspection also fails, Owner may pursue others Contract options to complete TAB work.
F. Prepare test and inspection reports.
3.13 ADDITIONAL TESTS
A. Within 90 days of completing TAB, perform additional TAB to verify that balanced conditions are being maintained throughout and to correct unusual conditions.
B. Seasonal Periods: If initial TAB procedures were not performed during near-peak summer and winter conditions, perform additional TAB during near-peak summer and winter conditions.
END OF SECTION 230593
283
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 1
SECTION 230713 - DUCT INSULATION
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes insulating the following duct services:
1. Indoor, concealed supply and outdoor air.
2. Indoor, concealed return located in unconditioned space.
3. Outdoor, concealed supply and return.
B. Related Requirements:
1. Section 230719 "HVAC Piping Insulation."
2. Section 233113 "Metal Ducts" for duct liners.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product indicated. Include thermal conductivity, water-vapor permeance thickness, and jackets (both factory- and field-applied if any).
B. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.
1. Detail application of protective shields, saddles, and inserts at hangers for each type of insulation and hanger.
2. Detail insulation application at elbows, fittings, dampers, specialties and flanges for each type of insulation.
3. Detail application of field-applied jackets.
4. Detail application at linkages of control devices.
C. Samples: For each type of insulation and jacket indicated. Identify each Sample, describing product and intended use. Sample sizes are as follows:
1. Sheet Form Insulation Materials: 12 inches (300 mm) square.
1.3 QUALITY ASSURANCE
A. Installer Qualifications: Skilled mechanics who have successfully completed an apprenticeship program or craft training program, certified by the Department of Labor, Bureau of Apprenticeship and Training.
1.4 DELIVERY, STORAGE, AND HANDLING
A. Packaging: Insulation material containers are to be marked with the manufacturer's name, appropriate ASTM standard designation, type and grade, and maximum use temperature. 284
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 2
1.5 COORDINATION
A. Coordinate sizes and locations of supports, hangers, and insulation shields specified in Section 230529 "Hangers and Supports for HVAC Piping and Equipment." B. Coordinate clearance requirements with duct Installer for duct insulation application. Before preparing ductwork Shop Drawings, establish and maintain clearance requirements for installation of insulation and field-applied jackets and finishes and for space required for maintenance.
C. Coordinate installation and testing of heat tracing.
1.6 SCHEDULING
A. Schedule insulation application after pressure testing systems and, where required, after installing and testing heat tracing. Insulation application may begin on segments that have satisfactory test results.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Surface-Burning Characteristics: For insulation and related materials, as determined by testing identical products in accordance with ASTM E84, by a testing agency acceptable to authorities having jurisdiction. Factory label insulation, jacket materials, adhesive, mastic, tapes, and cement material containers with appropriate markings of applicable testing agency.
1. All Insulation Installed Indoors: Flame-spread index of 25 or less, and smoke-developed index of 50 or less.
2.2 INSULATION MATERIALS
A. Products do not contain asbestos, lead, mercury, or mercury compounds.
B. Flexible Elastomeric: Closed-cell or expanded-rubber materials; suitable for maximum use temperature between minus 70 deg F (minus 57 deg C) and 220 deg F (104 deg C). Comply with ASTM C534, Type II for sheet materials.
C. Glass-Fiber Blanket: Glass fibers bonded with a thermosetting resin; suitable for maximum use temperature up to 450 deg F (232 deg C) in accordance with ASTM C411. Comply with ASTM C553, Type II, and ASTM C1290, Type III with factory-applied FSK jacket. Factoryapplied jacket requirements are specified in "Factory-Applied Jackets" Article.
2.3 ADHESIVES
A. Materials are compatible with insulation materials, jackets, and substrates and for bonding insulation to itself and to surfaces to be insulated unless otherwise indicated. 285
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 3
B. Glass-Fiber and Mineral Wool Adhesive: Comply with MIL-A-3316C, Class 2, Grade A.
C. ASJ Adhesive, and FSK Jacket Adhesive: Comply with MIL-A-3316C, Class 2, Grade A for bonding insulation jacket lap seams and joints.
2.4 LAGGING ADHESIVES
A. Description: Comply with MIL-A-3316C, Class I, Grade A and are compatible with insulation materials, jackets, and substrates.
1. Fire-resistant, water-based lagging adhesive and coating for use indoors to adhere fireresistant lagging cloths over duct insulation.
2. Service Temperature Range: 0 to plus 180 deg F (Minus 18 to plus 82 deg C).
2.5 SEALANTS
A. FSK and Metal Jacket Flashing Sealants:
1. Materials are compatible with insulation materials, jackets, and substrates.
2. Fire- and water-resistant, flexible, elastomeric sealant.
3. Service Temperature Range: Minus 40 to plus 250 deg F (Minus 40 to plus 121 deg C).
B. ASJ Flashing Sealants, and Vinyl and PVC Jacket Flashing Sealants:
1. 2. Materials are compatible with insulation materials, jackets, and substrates.
3. Fire- and water-resistant, flexible, elastomeric sealant.
4. Service Temperature Range: Minus 40 to plus 250 deg F (Minus 40 to plus 121 deg C).
2.6 FACTORY-APPLIED JACKETS
Coordinate types of factory-applied jacket insulation materials selected and types of factory-applied jackets indicated in insulation system schedules.
Knauf is the only glass-fiber insulation manufacturer that offers factory-applied FSP jacket for blanket insulation. CertainTeed and Johns Manville offer a vinyl jacket, but it does not comply with ASTM C1136. Owens Corning does not offer an FSP or a vinyl product.
A. Insulation system schedules indicate factory-applied jackets on various applications. When factory-applied jackets are indicated, comply with the following:
1. ASJ: White, kraft-paper, fiberglass-reinforced scrim with aluminum-foil backing; complying with ASTM C1136, Type I.
2. ASJ-SSL: ASJ with self-sealing, pressure-sensitive, acrylic-based adhesive covered by a removable protective strip; complying with ASTM C1136, Type I.
3. FSK Jacket: Aluminum-foil, fiberglass-reinforced scrim with kraft-paper backing; complying with ASTM C1136, Type II.
4. FSP Jacket: Aluminum-foil, fiberglass-reinforced scrim with polyethylene backing; complying with ASTM C1136, Type II.
286
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 4
5. Vinyl Jacket: White vinyl with a permeance of 1.3 perms (0.86 metric perm) when tested in accordance with ASTM E96/E96M, Procedure A, and complying with NFPA 90A and NFPA 90B.
6. ASJ+: All-service jacket composed of aluminum foil reinforced with glass scrim bonded to a kraft paper interleaving with an outer film leaving no paper exposed; complying with ASTM C1136, Types I, II, III, IV, and VII.
7. PSK Jacket: Aluminum foil, fiberglass-reinforced scrim with polyethylene backing; complying with ASTM C1136, Type II.
2.7 FIELD-APPLIED JACKETS
Insulation jackets in this article are for field application. ASTM C921, Type I, is for use over insulation on ducts operating at below ambient temperatures at least part of the time or where a vapor barrier is required. ASTM C921, Type II, is for use over insulation on ducts operating above ambient temperatures or where a vapor retarder is not required.
A. Field-applied jackets comply with ASTM C921, Type I, unless otherwise indicated.
A properly sealed FSK jacket, common with most forms of factory-applied jackets for mineral-fiber insulation, complies with vapor-retarder requirements in ASTM C921, Type I.
B. FSK Jacket: Aluminum-foil-face, fiberglass-reinforced scrim with kraft-paper backing.
Although other thicknesses for PVC jackets are available, a flame-spread index of 25 and a smokedeveloped index of 50 apply only to thicknesses of 30 mils (0.8 mm) and less.
C. PVC Jacket: High-impact-resistant, UV-resistant PVC complying with ASTM D1784, Class 16354-C; thickness as scheduled; roll stock ready for shop or field cutting and forming.
Thickness is indicated in field-applied jacket schedules.
1. Adhesive: As recommended by jacket material manufacturer.
PVC jackets are available in several colors. Colored jackets may be used to replace field painting. UV rays fade colors in exterior applications. Some colors (black, gray, and white) do not fade as quickly as other colors (red, orange, and green). Colored jackets have different emissivity and are not recommended for outdoor use.
2. Color: White.
D. Self-Adhesive Indoor/Outdoor Jacket (Non-Asphaltic): Vapor barrier and waterproofing jacket for installation over insulation located aboveground outdoors or indoors. Specialized jacket has five layers of laminated aluminum and polyester film with low-temperature acrylic pressuresensitive adhesive. Outer aluminum surface is coated with UV-resistant coating for protection from environmental contaminants.
1. Permeance: 0.00 perm as tested in accordance with ASTM F1249.
2. Flamespread/Smoke Developed: 25/50 as tested in accordance with ASTM E84.
3. Aluminum Finish: Embossed.
287
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 5
2.8 TAPES
A. FSK Tape: Foil-face, vapor-retarder tape matching factory-applied jacket with acrylic adhesive; complying with ASTM C1136.
1. Width: 3 inches (75 mm).
2. Thickness: 6.5 mils (0.16 mm).
3. Adhesion: 90 ounces force/inch (1.0 N/mm) in width.
4. Elongation: 2 percent.
5. Tensile Strength: 40 lbf/inch (7.2 N/mm) in width.
6. FSK Tape Disks and Squares: Precut disks or squares of FSK tape.
B. Aluminum-Foil Tape: Vapor-retarder tape with acrylic adhesive.
1. Width: 2 inches (50 mm).
2. Thickness: 3.7 mils (0.093 mm).
3. Adhesion: 100 ounces force/inch (1.1 N/mm) in width.
4. Elongation: 5 percent.
5. Tensile Strength: 34 lbf/inch (6.2 N/mm) in width.
2.9 SECUREMENTS
A. Bands:
1. Stainless Steel: ASTM A240/A240M, Type 304; 0.015 inch (0.38 mm) thick, 1/2 inch (13 mm) wide with wing seal or closed seal.
2. Aluminum: ASTM B209 (ASTM B209M), Alloy 3003, 3005, 3105, or 5005; Temper H14, 0.020 inch (0.51 mm) thick, 1/2 inch (13 mm) wide with wing seal or closed seal.
3. Springs: Twin spring set constructed of stainless steel with ends flat and slotted to accept metal bands. Spring size determined by manufacturer for application.
B. Insulation Pins and Hangers:
1. Capacitor-Discharge-Weld Pins: Copper- or zinc-coated steel pin, fully annealed for capacitor-discharge welding, 0.135-inch- (3.5-mm-) diameter shank, length to suit depth of insulation indicated.
2. Cupped-Head, Capacitor-Discharge-Weld Pins: Copper- or zinc-coated steel pin, fully annealed for capacitor-discharge welding, 0.106-inch- (2.6-mm) diameter shank, length to suit depth of insulation indicated with integral 1-1/2-inch (38-mm) galvanized carbonsteel washer.
3. Metal, Adhesively Attached, Perforated-Base Insulation Hangers: Baseplate welded to projecting spindle that is capable of holding insulation, of thickness indicated, securely in position indicated when self-locking washer is in place. Comply with the following requirements:
a. Baseplate: Perforated, galvanized carbon-steel sheet, 0.030 inch (0.76 mm) thick by 2 inches (50 mm) square.
b. Spindle: Copper- or zinc-coated, low-carbon steel, fully annealed, 0.106-inch- (2.6-mm-) diameter shank, length to suit depth of insulation indicated. 288
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 6
c. Adhesive: Recommended by hanger manufacturer. Product with demonstrated capability to bond insulation hanger securely to substrates indicated without damaging insulation, hangers, and substrates.
4. Nonmetal, Adhesively Attached, Perforated-Base Insulation Hangers: Baseplate fastened to projecting spindle that is capable of holding insulation, of thickness indicated, securely in position indicated when self-locking washer is in place. Comply with the following requirements:
a. Baseplate: Perforated, nylon sheet, 0.030 inch (0.76 mm) thick by 1-1/2 inches (38 mm) in diameter.
b. Spindle: Nylon, 0.106-inch- (2.6-mm-) diameter shank, length to suit depth of insulation indicated, up to 2-1/2 inches (63 mm).
c. Adhesive: Recommended by hanger manufacturer. Product with demonstrated capability to bond insulation hanger securely to substrates indicated without damaging insulation, hangers, and substrates.
5. Self-Sticking-Base Insulation Hangers: Baseplate welded to projecting spindle that is capable of holding insulation, of thickness indicated, securely in position indicated when self-locking washer is in place. Comply with the following requirements:
a. Baseplate: Galvanized carbon-steel sheet, 0.030 inch (0.76 mm) thick by 2 inches (50 mm) square.
b. Spindle: Copper- or zinc-coated, low-carbon steel, fully annealed, 0.106-inch- (2.6-mm-) diameter shank, length to suit depth of insulation indicated. c. Adhesive-backed base with a peel-off protective cover.
6. Insulation-Retaining Washers: Self-locking washers formed from 0.016-inch- (0.41-mm-) thick, galvanized-steel sheet, with beveled edge sized as required to hold insulation securely in place but not less than 1-1/2 inches (38 mm) in diameter. a. Protect ends with capped self-locking washers incorporating a spring steel insert to ensure permanent retention of cap in exposed locations.
7. Nonmetal Insulation-Retaining Washers: Self-locking washers formed from 0.016-inch- (0.41-mm-) thick nylon sheet, with beveled edge sized as required to hold insulation securely in place but not less than 1-1/2 inches (38 mm) in diameter.
C. Staples: Outward-clinching insulation staples, nominal 3/4-inch- (19-mm-) wide, stainless steel or Monel.
D. Wire: 0.062-inch (1.6-mm) soft-annealed, stainless steel.
2.10 CORNER ANGLES
A. Stainless Steel Corner Angles: 0.024 inch (0.61 mm) thick, minimum 1 by 1 inch (25 by 25 mm), stainless steel in accordance with ASTM A240/A240M, Type 304. 289
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 7
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates and conditions for compliance with requirements for installation tolerances and other conditions affecting performance of insulation application.
1. Verify that systems to be insulated have been tested and are free of defects.
2. Verify that surfaces to be insulated are clean and dry.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Surface Preparation: Clean and dry surfaces to receive insulation. Remove materials that will adversely affect insulation application.
3.3 GENERAL INSTALLATION REQUIREMENTS
A. Install insulation materials, accessories, and finishes with smooth, straight, and even surfaces; free of voids throughout the length of ducts and fittings.
B. Install accessories compatible with insulation materials and suitable for the service. Install accessories that do not corrode, compress, or otherwise damage insulation or jacket.
C. Install insulation with longitudinal seams at top and bottom of horizontal runs.
D. Install multiple layers of insulation with longitudinal and end seams staggered.
E. Keep insulation materials dry during application and finishing. Replace insulation materials that get wet during storage or in the installation process before being properly covered and sealed in accordance with Contract Documents.
F. Install insulation with tight longitudinal seams and end joints. Bond seams and joints with adhesive recommended by insulation material manufacturer.
G. Install insulation with least number of joints practical.
H. Apply adhesives, mastics, and sealants at manufacturer's recommended coverage rate and wet and dry film thicknesses.
I. Cut insulation in a manner to avoid compressing insulation.
J. Finish installation with systems at operating conditions. Repair joint separations and cracking due to thermal movement.
K. Repair damaged insulation facings by applying same facing material over damaged areas.
Extend patches at least 4 inches (100 mm) beyond damaged areas. Adhere, staple, and seal patches similar to butt joints.
290
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 8
3.4 PENETRATIONS
A. Insulation Installation at Interior Wall and Partition Penetrations (That Are Not Fire Rated):
Install insulation continuously through walls and partitions.
3.5 INSTALLATION OF GLASS-FIBER AND MINERAL-WOOL INSULATION A. Blanket Insulation Installation on Ducts and Plenums: Secure with adhesive and insulation pins.
B. Comply with manufacturer's written installation instructions.
1. Apply adhesives according to manufacturer's recommended coverage rates per unit area, for 100 percent coverage of duct and plenum surfaces.
2. Apply adhesive to entire circumference of ducts and to all surfaces of fittings and transitions.
3. Install either capacitor-discharge-weld pins and speed washers or cupped-head, capacitordischarge-weld pins on sides and bottom of horizontal ducts and sides of vertical ducts as follows:
a. On duct sides with dimensions 18 inches (450 mm) and smaller, place pins along longitudinal centerline of duct. Space 3 inches (75 mm) maximum from insulation end joints, and 16 inches (400 mm) o.c.
b. On duct sides with dimensions larger than 18 inches (450 mm), place pins 16 inches (400 mm) o.c. each way, and 3 inches (75 mm) maximum from insulation joints. Install additional pins to hold insulation tightly against surface at cross bracing.
c. Pins may be omitted from top surface of horizontal, rectangular ducts and plenums. d. Do not overcompress insulation during installation.
e. Impale insulation over pins and attach speed washers. f. Cut excess portion of pins extending beyond speed washers or bend parallel with insulation surface. Cover exposed pins and washers with tape matching insulation facing.
4. For ducts and plenums with surface temperatures below ambient, install a continuous unbroken vapor barrier. Create a facing lap for longitudinal seams and end joints with insulation by removing 2 inches (50 mm) from one edge and one end of insulation segment. Secure laps to adjacent insulation section with 1/2-inch (13-mm) outwardclinching staples, 1 inch (25 mm) o.c. Install vapor barrier consisting of factory- or fieldapplied jacket, adhesive, vapor-barrier mastic, and sealant at joints, seams, and protrusions.
a. Repair punctures, tears, and penetrations with tape or mastic to maintain vaporbarrier seal. b. Install vapor stops for ductwork and plenums operating below 50 deg F (10 deg C) at 18-foot (5.5-m) intervals. Vapor stops consist of vapor-barrier mastic applied in a Z-shaped pattern over insulation face, along butt end of insulation, and over the surface. Cover insulation face and surface to be insulated a width equal to two times the insulation thickness, but not less than 3 inches (75 mm). 291
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 9
5. Overlap unfaced blankets a minimum of 2 inches (50 mm) on longitudinal seams and end joints. At end joints, secure with steel bands spaced a maximum of 18 inches (450 mm) o.c.
6. Install insulation on rectangular duct elbows and transitions with a full insulation section for each surface. Install insulation on round and flat-oval duct elbows with individually mitered gores cut to fit the elbow.
7. Insulate duct stiffeners, hangers, and flanges that protrude beyond insulation surface with 6-inch- (150-mm-) wide strips of same material used to insulate duct. Secure on alternating sides of stiffener, hanger, and flange with pins spaced 6 inches (150 mm) o.c.
C. Board Insulation Installation on Ducts and Plenums: Secure with adhesive and insulation pins.
1. Apply adhesives according to manufacturer's recommended coverage rates per unit area, for 100 percent coverage of duct and plenum surfaces.
2. Apply adhesive to entire circumference of ducts and to all surfaces of fittings and transitions.
3. Install either capacitor-discharge-weld pins and speed washers or cupped-head, capacitordischarge-weld pins on sides and bottom of horizontal ducts and sides of vertical ducts as follows:
a. On duct sides with dimensions 18 inches (450 mm) and smaller, place pins along longitudinal centerline of duct. Space 3 inches (75 mm) maximum from insulation end joints, and 16 inches (400 mm) o.c.
b. On duct sides with dimensions larger than 18 inches (450 mm), space pins 16 inches (400 mm) o.c. each way, and 3 inches (75 mm) maximum from insulation joints. Install additional pins to hold insulation tightly against surface at cross bracing.
c. Pins may be omitted from top surface of horizontal, rectangular ducts and plenums. d. Do not overcompress insulation during installation.
e. Cut excess portion of pins extending beyond speed washers or bend parallel with insulation surface. Cover exposed pins and washers with tape matching insulation facing.
4. For ducts and plenums with surface temperatures below ambient, install a continuous unbroken vapor barrier. Create a facing lap for longitudinal seams and end joints with insulation by removing 2 inches (50 mm) from one edge and one end of insulation segment. Secure laps to adjacent insulation section with 1/2-inch (13-mm) outwardclinching staples, 1 inch (25 mm) o.c. Install vapor barrier consisting of factory- or fieldapplied jacket, adhesive, vapor-barrier mastic, and sealant at joints, seams, and protrusions.
a. Repair punctures, tears, and penetrations with tape or mastic to maintain vaporbarrier seal. b. Install vapor stops for ductwork and plenums operating below 50 deg F (10 deg C) at 18-foot (5.5-m) intervals. Vapor stops consist of vapor-barrier mastic applied in a Z-shaped pattern over insulation face, along butt end of insulation, and over the surface. Cover insulation face and surface to be insulated a width equal to two times the insulation thickness, but not less than 3 inches (75 mm).
5. Install insulation on rectangular duct elbows and transitions with a full insulation section for each surface. Groove and score insulation to fit as closely as possible to outside and 292
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 10
inside radius of elbows. Install insulation on round and flat-oval duct elbows with individually mitered gores cut to fit the elbow.
6. Insulate duct stiffeners, hangers, and flanges that protrude beyond insulation surface with 6-inch- (150-mm-) wide strips of same material used to insulate duct. Secure on alternating sides of stiffener, hanger, and flange with pins spaced 6 inches (150 mm) o.c.
3.6 FIELD QUALITY CONTROL
A. Testing Agency: Engage a qualified testing agency to perform tests and inspections.
B. Perform tests and inspections.
C. Tests and Inspections:
1. Inspect ductwork, randomly selected by Architect, by removing field-applied jacket and insulation in layers in reverse order of their installation. Extent of inspection is limited to one location for each duct system defined in the "Duct Insulation Schedule, General" Article.
3.7 DUCT INSULATION SCHEDULE, GENERAL
A. Plenums and Ducts Requiring Insulation:
1. Indoor, concealed supply and outdoor air.
2. Indoor, concealed return located in unconditioned space.
3. Outdoor, concealed supply and return.
B. Items Not Insulated:
1. Metal ducts with duct liner of sufficient thickness to comply with energy code and ASHRAE/IESNA 90.1.
2. Factory-insulated flexible ducts.
3. Factory-insulated plenums and casings.
4. Flexible connectors.
5. Vibration-control devices.
6. Factory-insulated access panels and doors.
3.8 INDOOR DUCT AND PLENUM INSULATION SCHEDULE
A. Concealed, round and flat-oval, supply-air duct insulation is the following:
1. Glass-Fiber Blanket: 2 inches (50 mm) thick and 1.5 lb/cu. ft. (24 kg/cu. m) nominal density.
B. Concealed, round and flat-oval, return-air duct insulation is the following:
1. Glass-Fiber Blanket: 2 inches (50 mm) thick and 1.5 lb/cu. ft. (24 kg/cu. m) nominal density.
293
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
DUCT INSULATION 230713 - 11
C. Concealed, rectangular, supply-air duct insulation is the following:
1. Glass-Fiber Blanket: 2 inches (50 mm) thick and 1.5 lb/cu. ft. (24 kg/cu. m) nominal density.
D. Concealed, rectangular, return-air duct insulation is the following:
1. Glass-Fiber Blanket: 2 inches (50 mm) thick and 1.5 lb/cu. ft. (24 kg/cu. m) nominal density.
END OF SECTION 230713
294
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HVAC PIPING INSULATION 230719 - 1
SECTION 230719 - HVAC PIPING INSULATION
PART 1 - GENERAL
1.1 SUMMARY
A. Section includes insulation for HVAC piping systems.
B. Related Requirements:
1. Section 230713 "Duct Insulation" for duct insulation.
1.2 ACTION SUBMITTALS
A. Product Data: For each type of product. Include thermal conductivity, water-vapor permeance thickness, and jackets (both factory and field applied, if any).
1.3 INFORMATIONAL SUBMITTALS
A. Field quality-control reports.
1.4 QUALITY ASSURANCE
A. Installer Qualifications: Skilled mechanics who have successfully completed an apprenticeship program or craft training program, certified by the Department of Labor, Bureau of Apprenticeship and Training.
1.5 COORDINATION
A. Coordinate sizes and locations of supports, hangers, and insulation shields specified in Section 230529 "Hangers and Supports for HVAC Piping and Equipment." B. Coordinate clearance requirements with piping Installer for piping insulation application.
Before preparing piping Shop Drawings, establish and maintain clearance requirements for installation of insulation and field-applied jackets and finishes and for space required for maintenance.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Surface-Burning Characteristics: For insulation and related materials, as determined by testing identical products in accordance with ASTM E84 by a testing agency acceptable to authority 295
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HVAC PIPING INSULATION 230719 - 2
having jurisdiction. Factory label insulation, jacket materials, adhesive, mastic, tapes, and cement material containers with appropriate markings of applicable testing agency.
1. All Insulation Installed Indoors and Outdoors: Flame-spread index of 25 or less, and smoke-developed index of 50 or less.
2.2 INSULATION MATERIALS
A. Products do not contain asbestos, lead, mercury, or mercury compounds.
B. Products that come into contact with stainless steel have a leachable chloride content of less than 50 ppm when tested in accordance with ASTM C871.
C. Insulation materials for use on austenitic stainless steel are qualified as acceptable in accordance with ASTM C795.
D. Foam insulation materials do not use CFC or HCFC blowing agents in the manufacturing process.
E. Flexible Elastomeric: Closed-cell, or expanded-rubber materials; suitable for maximum use temperature between minus 70 deg F (minus 57 deg C) and 220 deg F (104 deg C). Comply with ASTM C534/C534M, Type I, for tubular materials, Type II for sheet materials.
2.3 ADHESIVES
A. Flexible Elastomeric and Polyolefin Adhesive: Solvent-based adhesive.
1. Flame-spread index is 25 or less and smoke-developed index is 50 or less as tested in accordance with ASTM E84.
2. Wet Flash Point: Below 0 deg F (minus 18 deg C).
3. Service Temperature Range: 40 to 200 deg F (4 to plus 93 deg C).
4. Color: Black.
2.4 LAGGING ADHESIVES
A. Adhesives comply with MIL-A-3316C, Class I, Grade A, and are compatible with insulation materials, jackets, and substrates.
1. Fire-resistant, water-based lagging adhesive and coating for use indoors to adhere fireresistant lagging cloths over pipe insulation.
2. Service Temperature Range: 20 to plus 180 deg F (Minus 6 to plus 82 deg C).
3. Color: White.
2.5 SECUREMENTS
A. Wire: 0.062-inch (1.6-mm) soft-annealed, stainless steel. 296
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HVAC PIPING INSULATION 230719 - 3
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates and conditions for compliance with requirements for installation tolerances and other conditions affecting performance of insulation application.
1. Verify that systems to be insulated have been tested and are free of defects.
2. Verify that surfaces to be insulated are clean and dry.
B. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 PREPARATION
A. Clean and prepare surfaces to be insulated. Before insulating, apply a corrosion coating to insulated surfaces as follows:
1. Stainless Steel: Coat 300 series stainless steel with an epoxy primer 5 mils (0.127 mm) thick and an epoxy finish 5 mils (0.127 mm) thick if operating in a temperature range between 140 and 300 deg F (60 and 149 deg C). Consult coating manufacturer for appropriate coating materials and application methods for operating temperature range.
2. Carbon Steel: Coat carbon steel operating at a service temperature of between 32 and 300 deg F (0 and 149 deg C) with an epoxy coating. Consult coating manufacturer for appropriate coating materials and application methods for operating temperature range.
3.3 GENERAL INSTALLATION REQUIREMENTS
A. Install insulation materials, accessories, and finishes with smooth, straight, and even surfaces; free of voids throughout the length of piping, including fittings, valves, and specialties.
B. Install insulation materials, forms, vapor barriers or retarders, jackets, and of thicknesses required for each item of pipe system, as specified in insulation system schedules.
C. Install accessories compatible with insulation materials and suitable for the service. Install accessories that do not corrode, compress, or otherwise damage insulation or jacket.
D. Install insulation with longitudinal seams at top and bottom (12 o'clock and 6 o'clock positions) of horizontal runs.
E. Install multiple layers of insulation with longitudinal and end seams staggered.
F. Do not weld brackets, clips, or other attachment devices to piping, fittings, and specialties.
G. Keep insulation materials dry during storage, application, and finishing. Replace insulation materials that get wet during storage or in the installation process before being properly covered and sealed in accordance with the Contract Documents.
H. Install insulation with tight longitudinal seams and end joints. Bond seams and joints with adhesive recommended by insulation material manufacturer. 297
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HVAC PIPING INSULATION 230719 - 4
I. Install insulation with least number of joints practical.
J. Where vapor barrier is indicated, seal joints, seams, and penetrations in insulation at hangers, supports, anchors, and other projections with vapor-barrier mastic.
1. Install insulation continuously through hangers and around anchor attachments.
2. Install insert materials and insulation to tightly join the insert. Seal insulation to insulation inserts with adhesive or sealing compound recommended by insulation material manufacturer.
K. Apply adhesives, mastics, and sealants at manufacturer's recommended coverage rate and wet and dry film thicknesses.
L. Install insulation with factory-applied jackets as follows:
1. Draw jacket tight and smooth, but not to the extent of creating wrinkles or areas of compression in the insulation.
2. Cover circumferential joints with 3-inch- (75-mm-) wide strips, of same material as insulation jacket. Secure strips with adhesive and outward-clinching staples along both edges of strip, spaced 4 inches (100 mm) o.c.
3. For below-ambient services, apply vapor-barrier mastic over staples.
4. Cover joints and seams with tape, in accordance with insulation material manufacturer's written instructions, to maintain vapor seal.
5. Where vapor barriers are indicated, apply vapor-barrier mastic on seams and joints and at ends adjacent to pipe flanges and fittings.
M. Cut insulation in a manner to avoid compressing insulation.
N. Finish installation with systems at operating conditions. Repair joint separations and cracking due to thermal movement.
O. Repair damaged insulation facings by applying same facing material over damaged areas.
Extend patches at least 4 inches (100 mm) beyond damaged areas. Adhere, staple, and seal patches in similar fashion to butt joints.
P. For above-ambient services, do not install insulation to the following:
1. Vibration-control devices.
2. Testing agency labels and stamps.
3. Nameplates and data plates.
3.4 GENERAL PIPE INSULATION INSTALLATION
A. Requirements in this article generally apply to all insulation materials, except where more specific requirements are specified in various pipe insulation material installation articles below.
B. Insulation Installation on Fittings, Valves, Strainers, Flanges, Mechanical Couplings, and Unions:
298
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HVAC PIPING INSULATION 230719 - 5
1. Install insulation over fittings, valves, strainers, flanges, mechanical couplings, unions, and other specialties with continuous thermal and vapor-retarder integrity unless otherwise indicated.
2. Insulate pipe elbows using prefabricated fitting insulation or mitered or routed fittings made from same material and density as that of adjacent pipe insulation. Each piece is butted tightly against adjoining piece and bonded with adhesive. Fill joints, seams, voids, and irregular surfaces with insulating cement finished to a smooth, hard, and uniform contour that is uniform with adjoining pipe insulation.
3. Insulate tee fittings with prefabricated fitting insulation or sectional pipe insulation of same material and thickness as that used for adjacent pipe. Cut sectional pipe insulation to fit. Butt each section closely to the next and hold in place with tie wire. Bond pieces with adhesive.
4. Insulate valves using prefabricated fitting insulation or sectional pipe insulation of same material, density, and thickness as that used for adjacent pipe. Overlap adjoining pipe insulation by not less than 2 times the thickness of pipe insulation, or one pipe diameter, whichever is thicker. For valves, insulate up to and including the bonnets, valve stuffingbox studs, bolts, and nuts. Fill joints, seams, and irregular surfaces with insulating cement.
5. Insulate strainers using prefabricated fitting insulation or sectional pipe insulation of same material, density, and thickness as that used for adjacent pipe. Overlap adjoining pipe insulation by not less than 2 times the thickness of pipe insulation, or one pipe diameter, whichever is thicker. Fill joints, seams, and irregular surfaces with insulating cement. Insulate strainers, so strainer basket flange or plug can be easily removed and replaced without damaging the insulation and jacket. Provide a removable reusable insulation cover. For below-ambient services, provide a design that maintains vapor barrier.
6. Insulate flanges, mechanical couplings, and unions using a section of oversized preformed pipe insulation to fit. Overlap adjoining pipe insulation by not less than 2 times the thickness of pipe insulation, or one pipe diameter, whichever is thicker. Stencil or label the outside insulation jacket of each union with the word "union" matching size and color of pipe labels.
7. Cover segmented insulated surfaces with a layer of finishing cement and coat with a mastic. Install vapor-barrier mastic for below-ambient services and a breather mastic for above-ambient services. Reinforce the mastic with reinforcing mesh. Trowel the mastic to a smooth and well-shaped contour.
8. For services not specified to receive a field-applied jacket, except for flexible elastomeric and polyolefin, install fitted PVC cover over elbows, tees, strainers, valves, flanges, and unions. Terminate ends with PVC end caps. Tape PVC covers to adjoining insulation facing, using PVC tape.
C. Insulate instrument connections for thermometers, pressure gages, pressure temperature taps, test connections, flow meters, sensors, switches, and transmitters on insulated pipes. Shape insulation at these connections by tapering it to and around the connection with insulating cement and finish with finishing cement, mastic, and flashing sealant.
3.5 INSTALLATION OF FLEXIBLE ELASTOMERIC INSULATION
A. Seal longitudinal seams and end joints with manufacturer's recommended adhesive to eliminate openings in insulation that allow passage of air to surface being insulated. 299
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HVAC PIPING INSULATION 230719 - 6
B. Insulation Installation on Pipe Flanges:
1. Install pipe insulation to outer diameter of pipe flange.
2. Make width of insulation section same as overall width of flange and bolts, plus twice the thickness of pipe insulation.
3. Fill voids between inner circumference of flange insulation and outer circumference of adjacent straight pipe segments with cut sections of sheet insulation of same thickness as that of pipe insulation.
4. Secure insulation to flanges and seal seams with manufacturer's recommended adhesive to eliminate openings in insulation that allow passage of air to surface being insulated.
C. Insulation Installation on Pipe Fittings and Elbows:
1. Install sections of pipe insulation and miter if required in accordance with manufacturer's written instructions.
2. Secure insulation materials and seal seams with manufacturer's recommended adhesive to eliminate openings in insulation that allow passage of air to surface being insulated.
D. Insulation Installation on Valves and Pipe Specialties:
1. Install prefabricated valve covers manufactured of same material as that of pipe insulation when available.
2. When prefabricated valve covers are not available, install cut sections of pipe and sheet insulation to valve body. Arrange insulation to permit access to packing and to allow valve operation without disturbing insulation.
3. Install insulation to flanges as specified for flange insulation application.
4. Secure insulation to valves and specialties, and seal seams with manufacturer's recommended adhesive to eliminate openings in insulation that allow passage of air to surface being insulated.
3.6 FIELD QUALITY CONTROL
A. Perform tests and inspections with the assistance of a factory-authorized service representative.
B. Tests and Inspections: Inspect pipe, fittings, strainers, and valves, randomly selected by Architect, by removing field-applied jacket and insulation in layers in reverse order of their installation. Extent of inspection is limited to three locations of straight pipe, three locations of threaded fittings, three locations of welded fittings, two locations of threaded strainers, two locations of welded strainers, three locations of threaded valves.
C. All insulation applications will be considered defective if they do not pass tests and inspections.
D. Prepare test and inspection reports.
3.7 OUTDOOR, ABOVEGROUND PIPING INSULATION SCHEDULE
A. Refrigerant Suction and Hot-Gas Piping:
1. All Pipe Sizes: Insulation is the following:
300
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
HVAC PIPING INSULATION 230719 - 7
a. Flexible Elastomeric: 2 inches (50 mm) thick.
B. Refrigerant Suction and Hot-Gas Flexible Tubing:
1. All Pipe Sizes: Insulation is the following:
a. Flexible Elastomeric: 2 inches (50 mm) thick.
C. Refrigerant Liquid Piping:
1. All Pipe Sizes: Insulation is the following:
a. Flexible Elastomeric: 2 inches (50 mm)
END OF SECTION 230719
301
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TEMPERATURE INSTRUMENTS 230923.27 - 1
SECTION 230923.27 - TEMPERATURE INSTRUMENTS
PART 1 - GENERAL
1.1 SUMMARY
A. Section Includes:
1. Air temperature sensors.
1.2 ACTION SUBMITTALS
A. Product Data: For the following:
1. Air temperature sensors.
B. Product Data Submittals: For each product.
1. Construction details, material descriptions, dimensions of individual components and profiles, and finishes.
2. Operating characteristics, electrical characteristics, and furnished accessories indicating process operating range, accuracy over range, control signal over range, default control signal with loss of power, calibration data specific to each unique application, electrical power requirements, and limitations of ambient operating environment, including temperature and humidity.
3. Product description with complete technical data, performance curves, and product specification sheets.
4. Installation operation and maintenance instructions, including factors affecting performance.
C. Shop Drawings:
1. Include plans, elevations, sections, and mounting details.
2. Include details of product assemblies. Indicate dimensions, weights, loads, required clearances, method of field assembly, components, and location and size of each field connection.
3. Include diagrams for power, signal, and control wiring.
4. Include number-coded identification system for unique identification of wiring, cable, and tubing ends.
D. Samples: For each exposed product installed in finished space.
1.3 INFORMATIONAL SUBMITTALS
A. Product Certificates: For each product requiring a certificate. 302
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TEMPERATURE INSTRUMENTS 230923.27 - 2
1.4 MAINTENANCE MATERIAL SUBMITTALS
A. Furnish extra materials and parts that match products installed and that are packaged with protective covering for storage and identified with labels describing contents.
PART 2 - PRODUCTS
2.1 PERFORMANCE REQUIREMENTS
A. Environmental Conditions:
1. Instruments shall operate without performance degradation under the ambient environmental temperature, pressure, humidity, and vibration conditions specified and encountered for installed location.
2. Instruments and accessories shall be protected with enclosures satisfying the following minimum requirements unless more stringent requirements are indicated. Instruments not available with integral enclosures complying with requirements indicated shall be housed in protective secondary enclosures. Instrument's installed location shall dictate following NEMA 250 enclosure requirements:
a. Indoors, Heated and Air Conditioned: Type 1.
b. Within Duct Systems and Air-Moving Equipment Exposed to Possible Condensation: Type 4.
2.2 AIR TEMPERATURE SENSORS
A. Thermal Resistors (Thermistors): Common requirements:
1. 10,000 ohms at 25 deg C and a temperature coefficient of 23.5 ohms/ohm/deg C.
2. Two-wire, PTFE-insulated, 22-gage stranded copper leads.
3. Performance Characteristics:
a. Range: Minus 50 to 275 deg F (Minus 46 to 135 deg C). b. Interchangeable Accuracy: At 77 deg F (25 deg C) within 0.5 deg F (0.3 deg C). c. Repeatability: Within 0.5 deg F (0.3 deg C).
d. Drift: Within 0.5 deg F (0.3 deg C) over 10 years.
e. Self-Heating: Negligible.
4. Transmitter optional, contingent on compliance with end-to-end control accuracy.
B. Thermistor, Single-Point Duct Air Temperature Sensors:
1. Temperature Range: Minus 50 to 275 deg F (Minus 45 to 135 deg C).
2. Probe: Single-point sensor with a stainless steel sheath.
3. Length: As required by application to achieve tip at midpoint of air tunnel, up to 18 inches (450 mm) long.
4. Enclosure: Junction box with removable cover; NEMA 250, Type 1 for indoor applications and Type 4 for outdoor applications.
5. Gasket for attachment to duct or equipment to seal penetration airtight. 303
S&K Consulting Services, LLC The City of Rolling Hills
S&K No. 092226 Rolling Hills City Hall HVAC Repair
TEMPERATURE INSTRUMENTS 230923.27 - 3
6. Conduit Connection: 1/2-inch (16-mm) trade size.
C. Thermistor Averaging Air Temperature Sensors:
1. Temperature Range: Minus 50 to 275 deg F (Minus 45 to 135 deg C).
2. Multiple sensors to provide average temperature across entire length of sensor.
3. Rigid probe of aluminum, brass, copper, or stainless steel sheath.
4. Flexible probe of aluminum, brass, copper, or stainless steel sheath and formable to a 4- inch (100-mm) radius.
5. Length: As required by application to cover entire cross section of air tunnel.
6. Enclosure: Junction box with removable cover; NEMA 250, Type 1 for indoor applications and Type 4 for outdoor applications.
7. Gasket for attachment to duct or equipment to seal penetration airtight.
8. Conduit Connection: 1/2-inch (16-mm) trade size.
D. Thermistor Space Air Temperature Sensors:
1. Temperature Range: Minus 50 to 212 deg F (Minus 45 to 100 deg C).
2. Sensor assembly shall include a temperature sensing element mounted under a bright white, non-yellowing, plastic cover.
3. Provide a mounting plate that is compatible with the surface shape that it is mounted to and electrical box used.
4. Concealed wiring connection.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine substrates and conditions for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.