11. PER GENERAL EXPLANATORY NOTE #4 IN THE GYPSUM ASSOCIATION FIRE RESISTANCE DESIGN MANUAL GA-600 2015, SCREWS MEETING ASTM C 1002 SHALL BE PERMITTED TO BE SUBSTITUTED FOR THE PRESCRIBED NAILS, ONE FOR ONE,
WHEN THE LENGTH AND HEAD DIAMETER OF THE SCREWS EQUAL OR EXCEED THOSE OF THE NAILS SPECIFIED IN THE
TESTED SYSTEM AND THE SCREW SPACING DOES NOT EXCEED THE SPACING SPECIFIED FOR THE NAILS IN THE TESTED SYSTEM.
-
---
-
---
ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD APPLIED
PARALLEL OR AT RIGHT ANGLES TO EACH SIDE OF 2X4
WOOD STUDS 16" O.C. STAGGERED 8" O.C. ON 2X6
WOOD PLATES WITH 6d COATED NAILS, 1 7/8" LONG,
0.0915" SHANK, 1/4" HEADS, 7" O.C. JOINTS STAGGERED
24" ON OPPOSITE SIDES. HORIZONTAL BRACING
REQUIRED AT MID HEIGHT. (LOAD BEARING)
WOOD STRUCTURAL PANELS, SEE STRUCTURAL
DWGS
UNIT CORRIDOR
1" MINERAL WOOL VERTICAL FIRE STOPPING @ 10'-0"
INTERVALS
5 1/2" MINIMUM SOUND BATT INSULATION, SEE
INSULATION SCHEDULE
FIRE RATING: ONE HOUR
STC: 50 MIN PER NRC TL 93-225
ASSEMBLY: GA FILE NO. WP 3371
ADD ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD
AT BEDROOM WALLS ADJACENT TO CORRIDORS
ADD ONE LAYER 5/8" TYPE X GYPSUM WALLBOARD
AT BEDROOM WALL ADJACENT TO CORRIDOR
PER GA-600-2015 FIRE RESISTANCE DESIGN MANUAL:
SCREWS MEETING ASTM C 1002 SHALL BE PERMITTED
TO BE SUBSTITUTED FOR THE NAILS, ONE FOR ONE,
WHEN THE LENGTH AND HEAD DIAMETER OF THE
SCREWS EQUAL OR EXCEED THOSE OF THE NAILS
SPECIFIED IN THE TESTED SYSTEM AND THE SCREW
SPACING DOES NOT EXCEED THE SPACING SPECIFIED
FOR THE NAILS IN THE TESTED SYSTEM.
INSULATION PER INSULATION SCHEDULE
ELEVATOR / STAIR
FIRE RATING: TWO HOUR
STC: 53
ASSEMBLY: GA FILE NO. WP 4135
RATED ASSEMBLY
2x4 WOOD STUDS or 3 5/8" or 6" METAL
STUDS 16" O.C. WITH ONE LAYER 5/8" TYPE X
GYPSUM WALLBOARD
CALIFORNIA OFFICE OF NOISE CONTROL
1.2.4.1.5.14 STC 53
BASE LAYER 5/8" TYPE X GYPSUM WALLBOARD
APPLIED AT RIGHT ANGLES TO EACH SIDE OF
MINIMUM 2X4 WOOD STUDS MAXIMUM 16" O.C.
WITH 6d COATED NAILS, 1 7/8" LONG, 0.085"
SHANK, 1/4" HEADS, 24" O.C. FACE LAYER 5/8"
TYPE X GYPSUM WALLBOARD APPLIED AT
RIGHT ANGLES TO EACH SIDE WITH 8d COATED
NAILS, 2 3/8" LONG, 0.100" SHANK, 1/4" HEADS,
8" O.C.
JOINTS STAGGERED 24" O.C. EACH LAYER AND
SIDE. SOUND TESTED WITH 16" O.C. AND WITH
NAILS FOR BASE LAYER SPACED 6" O.C.. (LOAD
BEARING)
PER GA-600-2015 FIRE RESISTANCE DESIGN
MANUAL: SCREWS MEETING ASTM C 1002 SHALL
BE PERMITTED TO BE SUBSTITUTED FOR THE
NAILS, ONE FOR ONE, WHEN THE LENGTH AND
HEAD DIAMETER OF THE SCREWS EQUAL OR
EXCEED THOSE OF THE NAILS SPECIFIED IN THE
TESTED SYSTEM AND THE SCREW SPACING
DOES NOT EXCEED THE SPACING SPECIFIED
FOR THE NAILS IN THE TESTED SYSTEM.
ALTERNATE: REF: CBC 721.1 (2) 15-1.7
2"
6" MIN.
ALTERNATE: REF: CBC 721.1 (2) 14-1.5
BASE LAYER 5/8" TYPE X GYPSUM WALLBOARD
APPLIED AT RIGHT ANGLES TO EACH SIDE OF
MINIMUM 2X4 WOOD STUDS MAXIMUM 24" O.C.
WITH 6d COATED NAILS, 1 7/8" LONG, 0.085"
SHANK, 1/4" HEADS, 24" O.C. FACE LAYER 5/8"
TYPE X GYPSUM WALLBOARD APPLIED AT RIGHT
ANGLES TO EACH SIDE WITH 8d COATED NAILS, 2
3/8" LONG, 0.100" SHANK, 1/4" HEADS, 8" O.C.
JOINTS STAGGERED 24" O.C. EACH LAYER AND
SIDE. SOUND TESTED WITH 16" O.C. AND WITH
NAILS FOR BASE LAYER SPACED 6" O.C.. (LOAD
BEARING)
FIRE RATING: TWO HOUR
STC: 40 to 44
ASSEMBLY: GA FILE NO. WP 4135
RATED ASSEMBLY
WOOD STRUCTURAL PANELS PER
STRUCTURAL DRAWING
FIBERGLASS INSULATION PER
INSULATION SCHEDULE
PER GA-600-2015 FIRE RESISTANCE DESIGN
MANUAL: SCREWS MEETING ASTM C 1002 SHALL
BE PERMITTED TO BE SUBSTITUTED FOR THE
NAILS, ONE FOR ONE, WHEN THE LENGTH AND
HEAD DIAMETER OF THE SCREWS EQUAL OR
EXCEED THOSE OF THE NAILS SPECIFIED IN THE
TESTED SYSTEM AND THE SCREW SPACING
DOES NOT EXCEED THE SPACING SPECIFIED
FOR THE NAILS IN THE TESTED SYSTEM.
AIRGAP
1" OR 2"
1" MINERAL WOOL FIRE STOPPING AT
10'-0" O.C. VERTICAL INTERVALS
FIRE RATING: TWO HOUR
STC: 65 to 69
ASSEMBLY: GA FILE NO. WP 3725
RATED ASSEMBLY
NOTE:
APPLY WOOD STRUCTURAL PANELS PER
STRUCTURAL DRAWINGS TO STUDS
PRIOR TO APPLICATION OF FINISHES
BASE LAYER 5/8” TYPE X GYPSUM
WALLBOARD OR GYPSUM VENEER BASE
APPLIED AT RIGHT ANGLES TO EACH SIDE OF
DOUBLE ROW OF 2 X 4 WOOD STUDS 16” O.C.
ON SEPARATE PLATES 1” APART WITH 2” TYPE
W SCREWS 24” O.C. FACE LAYER 5/8” TYPE X
GYPSUM WALLBOARD OR GYPSUM VENEER
BASE APPLIED AT RIGHT ANGLES TO EACH
SIDE WITH 2-1/2” TYPE W SCREWS, 8” O.C. TWO
LAYERS 3.5” UNFACED GLASS FIBER
INSULATION FRICTION FIT BETWEEN STUD,
ONE PER SIDE.
JOINTS STAGGERED 16” EACH LAYER AND
SIDE. HORIZONTAL BRACING REQUIRED AT
MID-HEIGHT.
(LOAD-BEARING)
PER GA-600-2015 FIRE RESISTANCE DESIGN
MANUAL: SCREWS MEETING ASTM C 1002
SHALL BE PERMITTED TO BE SUBSTITUTED FOR
THE NAILS, ONE FOR ONE, WHEN THE LENGTH
AND HEAD DIAMETER OF THE SCREWS EQUAL
OR EXCEED THOSE OF THE NAILS SPECIFIED IN
THE TESTED SYSTEM AND THE SCREW
SPACING DOES NOT EXCEED THE SPACING
SPECIFIED FOR THE NAILS IN THE TESTED
SYSTEM.
0' - 11 1/2"
NOTE: APPLY SHEATHING PER
STRUCTURAL DRAWINGS.
1. ONE LAYER OF BATT INSULATION
SNUGLY FITTED BETWEEN THE STUDS
WHERE PIPING OCCURS.
FIRE RETARDANT TREATED PLYWOOD
SHEATHING WHERE OCCURS. REFER
TO STRUCTURAL DRAWINGS.
5/8" TYPE "X" GYPSUM BOARD, SEE
DETAIL 2 THIS SHEET FOR APPLICATION
DOUBLE 2x6 STUDS MIN. AT 16" O.C.
MAX. WITH BATT. INSULATION PER
SCHEDULE
3 COAT CEMENT PLASTER & LATH O/ 2
LAYERS GRADE D BLDG. PAPER OR WP
PER WP DOCS.
NOTE:
WHERE WASTE AND WATER SUPPLY
PIPING IS REQUIRED IN INTERIOR
PARTITION WALLS THE PARTITION
WALL SHALL BE CONSTRUCTED WITH
THE FOLLOWING REVISIONS :
REF: CBC 721.1 (2) 15-1.3
MIN. 0' - 11 1/2"
SEE SHEET FOR PENETRATION
DETAILS A-61.11
-
FIRE RETARDANT TREATED FRAMING
INT. EXT.
NOTE:
GYPSUM WALLBOARD SHALL BE APPLIED
WITH HORIZONTAL JOINTS STAGGERED NOT
LESS THAN 12" ON OPPOSITE SIDES
SEE SHEET FOR PENETRATION DETAILS A-75.1
-
WOOD STRUCTURAL PANELS, WHERE OCCURS,
PER STRUCTURAL DRAWINGS. APPLY TO STUDS
PRIOR TO APPLICATION OF FINISHES
UNIT/CORRIDOR
FIRE RATING: ONE HOUR
STC: 56-58 PER ACOUSTICAL REPORT
ASSEMBLY: GA FILE NO. WP 5513
UNIT
1HR WALL PER DETAILS 3/ 9 ON THIS SHEET
**
2X WOOD STUD OR MTL STUD
FRAMING
** 6" AT BATHS
** 6" AT KITCHEN
FIRE RATING: TWO HOUR
STC: NA
ASSEMBLY: CBC TABLE 721.1(2) 15-1.6
NOTE: APPLY WOOD STRUCUTRAL PANEL
PER STRUCTURAL DRAWINGS TO STUDS
PRIOR TO APPLICATION OF FINISHES.
INT.
PER PLANS
2 OR 6/A-61.51PER PLANS
RATED ASSEMBLY
EXTERIOR FINISH PER
ELEVATIONS
5/8" TYPE 'X' GYPSUM
SHEATHING OVER 2X WOOD
STUD WALL PER STRUCTURAL
DRAWINGS
FIRE RETARDANT TREATED
FRAMING (TYPICAL)
INTERIOR SIDE: ONE LAYER 5/8" TYPE 'X'
GYPSUM WALLBOARD, WATER-RESISTANT
GYPSUM BACKING BOARD, OR GYPSUM VENEER
BASE APPLIED PARALLEL OR AT RIGHT
ANGLES TO STUDS WITH 6D COATED NAILS,
1 7/8" LONG,0.0915" SHANK, 1/4" HEADS, 7" O.C.
(LOAD-BEARING)
INSULATION PER SCHEDULE
FIRE RATING: ONE HOUR
STC: NA
ASSEMBLY: GA WP 8105
EXTERIOR SIDE: ONE LAYER 48" WIDE 5/8"
TYPE 'X' GYPSUM SHEATHING APPLIED PARALLEL
TO MIN 2 X4 WOOD STUDS 24" O.C. WITH 1 3/4"
GALVANIZED ROOFING NAILS
4" O.C. AT VERTICAL JOINTS AND 7" O.C. AT
INTERMEDIATE STUDS AND TOP AND BOTOM
PLATES.
JOINTS OF GYPSUM SHEATHING MAY BE LEFT
UNTREATED.
EXTERIOR FIBER CEMENT SIDING TO BE ATTACHED
THROUGH SHEATHING TO STUDS.
FIRE RETARDANT TREATED STUD FRAMING
PER STRUCTURAL PLANS
3 1/2" UNFACED GLASS FIBER FRICTION FIT IN STUD INT. EXT. SPACE.
WEATHER BARRIER PER BUILDING ENVELOPE
DRAWINGS
REFER TO SHEETS
A2-10.10
A3-10.10
A4-10.10
FOR EXTERIOR LOAD BEARING WALL
LOCATIONS AT LOAD BEARING WALLS
USE DETAIL 6 ON THIS SHEET
FIRE TEST SEE WP 3510
INTERIOR SIDE: ONE LAYER 5/8" TYPE 'X'
GYPSUM WALLBOARD, WATER-RESISTANT
GYPSUM BACKING BOARD, OR GYPSUM VENEER
BASE APPLIED PARALLEL OR AT RIGHT
ANGLES TO STUDS WITH 6D COATED NAILS,
1 7/8" LONG,0.0915" SHANK, 1/4" HEADS, 7" O.C.
(LOAD-BEARING)
INSULATION PER SCHEDULE
FIRE RATING: ONE HOUR
STC: NA
ASSEMBLY: GA WP 8105
EXTERIOR SIDE: ONE LAYER 48" WIDE 5/8"
TYPE 'X' GYPSUM SHEATHING APPLIED PARALLEL
TO MIN 2 X4 WOOD STUDS 24" O.C. WITH 1 3/4"
GALVANIZED ROOFING NAILS
4" O.C. AT VERTICAL JOINTS AND 7" O.C. AT
INTERMEDIATE STUDS AND TOP AND BOTOM
PLATES.
JOINTS OF GYPSUM SHEATHING MAY BE LEFT
UNTREATED.
EXTERIOR CLADING TO BE ATTACHED
THROUGH SHEATHING TO STUDS.
FIRE RETARDANT TREATED STUD FRAMING
PER STRUCTURAL PLANS
3 1/2" UNFACED GLASS FIBER FRICTION FIT IN INT. EXT. STUD SPACE.
WEATHER BARRIER PER BUILDING ENVELOPE
DRAWINGS
REFER TO SHEETS
A2-10.10
A3-10.10
A4-10.10
FOR EXTERIOR LOAD BEARING WALL
LOCATIONS AT LOAD BEARING WALLS
USE DETAIL 6 ON THIS SHEET
FIRE TEST SEE WP 3510
NOTE:
GYPSUM WALLBOARD SHALL BE APPLIED
WITH HORIZONTAL JOINTS STAGGERED NOT
LESS THAN 12" ON OPPOSITE SIDES
SEE SHEET FOR PENETRATION DETAILS A-XX
-
UNIT
5/8" GYPSUM BOARD OVER 2X4 WOOD STUDS
FRAMING PER PLANS
RENEWAL
DATE
RCHIT ECT
ED S NE IC L
A
ALI FOR N IA
O F E T AT S
C
JOHNNY C. LU
C-30396
6/30/2023
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1ST BUILDING DEPT SUBMITTAL 05-31-2022
5/31/2022 1ST PLAN CHECK
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt WOOD
FRAMED
WALL
ASSEMBLIES
A7.31
3" = 1'-0" 2
1-HR EXT. (NON-BEARING) WALL
3" = 1'-0" 5
1-HR INT. WALL - TYP.
3" = 1'-0" 6
2-HR EXT. (BEARING) WALL
3" = 1'-0" 14 3-HR FIREWALL AT INTERIOR
12" = 1'-0" 1 WOOD FRAME WALL GENERAL NOTES
3" = 1'-0" 3
1-HR CORRIDOR WALL
3" = 1'-0" 11
2-HR RATED WALL
3" = 1'-0" 7
2 HR INTERIOR STUD WALL
3" = 1'-0" 10
1-HR WALL PARTITION
3" = 1'-0" 4
1-HR EXT. DBL. (NON-BEARING) WALL
3" = 1'-0" 15 1-HR PLUMBING WALL @ CORRIDOR WALL
3" = 1'-0" 8
2-HR EXT. (BEARING)-FURRED WALL
3" = 1'-0" 13 1-HR EXT. (NON-BEARING) WALL - SIDING
3" = 1'-0" 12
1-HR (NON-BEARING) WALL - RAINSCREEN
3" = 1'-0" 9
NON-RATED FURRING WALL
Date Issues / Revisions:
City Council 22 – 122 12/6/2022
SOLID 4x OR 6x FRAMING
MEMBER, FRAMING MEMBER TO
MATCH WIDTH OF WALL
WALL FRAMING PER PLANS
CORRIDOR STAIR
CONTINUOUS DOUBLE 2x
JOISTS OR BLOCKS WHERE
FLOOR FRAMING IS
PERPENDICULAR TO WALL
1/2" GYPSUM WALLBOARD OVER
NON-COMBUSTIBLE FRAMING
INSULATION PER SCHEDULE
FIRE MEMBRANE PER FLOOR
PLANS AND WALL SCHEDULE
TOP OF SHEATHNG
PER SECTIONS
BLOCK AS REQUIRED FOR
DRYWALL AND BASE
ATTACHMENT
TOP OF FINISH
FLOOR AT UNITS
SLOPE
TO DRAIN
ROOF FRAMING PER
STRUCTURAL DRAWINGS
FIRE CAULKING FOR
DRYWALL CUT
OUT FOR FRAMING
MEMBERS
CONTINUOUS FIRE BARRIER
TO THE UNDERSIDE OF
PLYWOOD SHEATHING
FIRE CAULKING FOR
DRYWALL CUT OUT FOR
FRAMING MEMBERS AT
PERPENDICULAR
CONDITIONS
NON-COMBUSTIBLE
FRAMING
INSULATION PER SCHEDULE
CORRIDOR STAIR
ROOF FRAMING TO BE
TRUSSES. PROVIDE
INSULATION AT CRICKET
CONDITIONS
FLOOR JOISTS PER
STRUCTURAL DRAWINGS
WALL FRAMING PER PLANS
CORRIDOR UNIT
CONTINUOUS 2x BLOCKING FIT
TIGHT TO FLOOR JOISTS,
ABOVE FIRE MEMBRANE
FIRE RATED ACOUSTICAL
JOINT PER ACOUSTICAL
REPORT
1/2" GYPSUM WALLBOARD
OVER NON-COMBUSTIBLE
FRAMING
INSULATION PER SCHEDULE
TOP OF FINISH
FLOOR AT UNITS
STAGGERED STUD WHERE
INDICATED ON PLANS
BLOCK AS REQUIRED FOR
DRYWALL AND BASE ATTACHMENT
FIRE RATED ACOUSTICAL
JOINT PER ACOUSTICAL
REPORT
STAGGERED STUD WHERE
INDICATED ON PLANS
FIRE MEMBRANE PER FLOOR
PLANS AND WALL SCHEDULE
2X CONTINUOUS BLOCKING
NON-COMBUSTIBLE FRAMING
INSULATION PER SCHEDULE
DRAFTSTOPPING AT FIRE
PARTITION PER CBC 2013 SECTION
718
SLOPE
TO DRAIN
CORRIDOR UNIT
5/8" TYPE 'X' GYPSUM WALLBOARD
DRAFTSTOPPING
ISOLATE GYPSUM BOARD 1/8"
FROM WALL FILL AIR SPACE TIGHT
WITH ACOUSTICAL CAULKING,
TYPICAL ALL ROOMS
WOOD STRUCTURAL PANELS,
SEE STRUCTURAL DRAWINGS
ROOF FRAMING PER
STRUCTURAL DRAWINGS
ROOF FRAMING TO BE
TRUSSES. PROVIDE
INSULATION AT CRICKET
CONDITIONS
FLOOR JOISTS PER
STRUCTURAL DRAWINGS
WALL FRAMING PER PLANS
UNIT STAIR
INSULATION PER SCHEDULE
WOOD STRUCTURAL
PANELS, SEE STRUCTURAL
DRAWINGS
TOP OF FINISH
FLOOR AT UNITS
SOLID 4x OR 6x FRAMING
MEMBER AT STAIR SIDE.
FRAMING MEMBER WIDTH
TO MATCH WALL WIDTH
DOUBLE 2x BLOCKING AS
REQUIRED FOR
ATTACHMENT OF DRYWALL
FIRE RATED ACOUSTICAL
JOINT PER ACOUSTICAL
REPORT
FIRE MEMBRANE PER
FLOOR AND WALL
SCHEDULE
FIRE RATED ACOUSTICAL
JOINT PER ACOUSTICAL
REPORT
BLOCK AS REQUIRED FOR
DRYWALL / BASE
ATTACHMENT
FLOOR JOISTS PER
STRUCTURAL DRAWINGS
FIRE CAULKING FOR
DRYWALL CUT OUT FOR
FRAMING MEMBERS
CONTINUOUS FIRE BARRIER
TO THE UNDERSIDE OF
PLYWOOD SHEATHING
FIRE CAULKING FOR
DRYWALL CUT OUT FOR
FRAMING MEMBERS AT
PERPENDICULAR
CONDITIONS
INSULATION PER SCHEDULE
WOOD STRUCTURAL PANELS,
SEE STRUCTURAL DRAWINGS
SLOPE
TO DRAIN
UNIT STAIR
ROOF FRAMING TO BE
TRUSSES. PROVIDE
INSULATION AT CRICKET
CONDITIONS
FLOOR JOISTS PER
STRUCTURAL
DRAWINGS
WOOD STRUCTURAL
PANEL PER
STRUCTURAL
DRAWINGS
WALL FRAMING PER
PLANS
CORRIDOR STORAGE
2x BLOCKING
2x BLOCKING AS
REQUIRED
RIS
E
R
H
T.
T
O
M
A
T
C
H
DOOR AND FRAME PER PLAN
W/ BOTTOM DRIP
G.I. FLASHING, PAINT SAFETY
YELLOW. SLOPE FLASHING TO
EXTERIOR
2 HOUR WALL PER PLAN
ROOF WATERPROOFING PER
SPEC'S AND W.P. DOCUMENTS
PLYWD LAYER OVER WOOD
FRAMING SLOPED TO ROOF
DRAIN 1/2"/FT. MIN.
FLOOR FRAMING PER
STRUCTURAL
FIN. FLOOR AT LANDING, SEE
STAIR SECTIONS
2 HOUR WALL
PER PLAN
ROOF WATERPROOFING PER
SPEC'S AND W.P.
DOCUMENTS RIGID INSULATION
SLOPED TO ROOF DRAIN
WOOD TRUSS PER
STRUCTURAL
FIN. FLOOR AT
LANDING, SEE
STAIR SECTIONS
STAIR
STAIR ROOF
EXTERIOR PLASTER
FIRE BARRIER TO BE
CONTINUOUS TO THE
UNDERSIDE OF PLYWOOD
SHEATHING. PROVIDE FIRE
CAULKING AT DRYWALL CUT- OUTS FOR FRAMING
MEMBERS AT
PERPENDICULAR
CONDITIONS
5/8" FIBER GLASS MAT
FACED GYPSUM BOARD
FLOOR JOISTS PER
STRUCTURAL
FIRE RETARDANT WOOD
STRUCTURAL PANEL PER
STRUCTURAL DRAWINGS
UNIT EXTERIOR
INSULATION PER SCHEDULE
FIRE BARRIER PER CBC 707
TOP OF FINISH
FLOOR AT UNITS
2X RIM JOIST REFER TO
STRUCTURAL DRAWINGS
CONTROL JOINT PER
EXTERIOR ELEVATIONS
UNIT
FIRE RETARDANT PLYWOOD
WITHIN 4'-0" OF EXTERIOR
WALL
2X BLOCKING PER
STRUCTURAL
ALL WOOD FRAMING MEMBERS
WITH IN EXTERIOR WALLS
TO BE FIRE RETARDANT TREATED
PER CBC SECTION 602.3
4'-0" OF EXTERIOR WALLS
FIRE RETARDANT PLYWOOD WITH IN
FLOOR JOISTS PER
STRUCTURAL
WOOD STRUCTURAL
PANEL PER STRUCTURAL
DRAWINGS
UNIT BALCONY
INSULATION PER SCHEDULE
TOP OF FINISH
FLOOR AT UNITS
RIM JOIST REFER TO
STRUCTURAL DRAWINGS
UNIT
MECHANICAL DUCT
WHERE OCCURS
FLOOR JOISTS PER
STRUCTURAL DRAWINGS
WALL FRAMING PER PLANS
STAIR
INSULATION PER SCHEDULE
WOOD STRUCTURAL
PANELS, SEE STRUCTURAL
DRAWINGS
SOLID 4x OR 6x FRAMING
MEMBER AT STAIR SIDE.
FRAMING MEMBER WIDTH
TO MATCH WALL WIDTH
DOUBLE 2x BLOCKING AS
REQUIRED FOR
ATTACHMENT OF DRYWALL
FLOOR FINISH PER SCHEDULE
FLOOR JOISTS PER
STRUCTURAL
FIRE RETARDANT WOOD
STRUCTURAL PANEL PER
STRUCTURAL DRAWINGS
UNIT EXTERIOR
INSULATION PER SCHEDULE
FIRE BARRIER PER CBC 707
TOP OF FINISH
FLOOR AT UNITS
2X RIM JOIST REFER TO
STRUCTURAL DRAWINGS
CONTROL JOINT PER
EXTERIOR ELEVATIONS
UNIT
4'-0" OF EXTERIOR WALLS
FIRE RETARDANT PLYWOOD WITH IN
FIRE RETARDANT PLYWOOD
WITHIN 4'-0" OF EXTERIOR
WALL
HANGAR PER
STRUCTURAL
ALL WOOD FRAMING MEMBERS
WITH IN EXTERIOR WALLS
TO BE FIRE RETARDANT TREATED
PER CBC SECTION 602.3
RENEWAL
DATE
RCHIT ECT
ED S NE IC L
A
ALI FOR N IA
O F E T AT S
C
JOHNNY C. LU
C-30396
6/30/2023
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1ST BUILDING DEPT SUBMITTAL 05-31-2022
5/31/2022 1ST PLAN CHECK
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt WOOD
CONNECTION
DETAILS
1 1/2" = 1'-0" 1 A7.32
FLOOR AT CORRIDOR/STAIR LEVEL 2
1 1/2" = 1'-0" 10
FLOOR AT CORRIDOR/STAIR ROOF
1 1/2" = 1'-0" 2
FLOOR AT UNIT/CORRIDOR
1 1/2" = 1'-0" 13 FLOOR AT UNIT/CORRIDOR ROOF
1 1/2" = 1'-0" 7
FLOOR AT UNIT/STAIR
1 1/2" = 1'-0" 6
FLOOR AT UNIT/STAIR ROOF
1 1/2" = 1'-0" 8
1-HR FLOOR-CLG AT CORR./STOR.
1 1/2" = 1'-0" 4
EXT. STAIR UP AT LANDING
1 1/2" = 1'-0" 9
EXT. STAIR / CORRIDOR AT ROOF LEVEL
1 1/2" = 1'-0" 11
1-HR EXT. FLOOR FRAMING(PARALLEL)
1 1/2" = 1'-0" 12
FLOOR FRAMING AT UNIT/BALCONY
1 1/2" = 1'-0" 3
STAIR LANDING
1 1/2" = 1'-0" 5
2-HR EXT. FLOOR
FRAMING(PERPENDICULAR)
Date Issues / Revisions:
City Council 22 – 123 12/6/2022
D SECTION AT HOPPER AND DISCHARGE
NOTE:
PROVIDE AUTOMATIC FIRE
SPRINKLER IN TRASH ROOM
WILKINSON TYPE-A ROLLING
FIRE DOOR WITH 165 DEG F.
FUSIBLE LINK, SHOWN IN
CLOSED POSITION
CHUTE FRAME SUPPORT
WILKINSON STAINLESS
STEEL CLAD BOTTOM
HINGED, HAND OPERATED,
U.L. APPROVED 90 MIN., B- LABEL INTAKE DOOR W/ 250
DEG. MAXIMUM
TEMPERATURE RISE IN 30.
MIN.,SELF CLOSING AND
LATCHING WITH LEVER
OPERATOR. MAXIMUM 5
LBS. OPERATING
PRESSURE REQUIRED TO
OPEN.
COAT CHUTE WITH
SOUNDCOAT GP-1
C ELEVATION AT HOPPER
CHUTE DOOR FRAME
(90 MINUTE FRAME)
QUIET LATCHING
CHUTE DOOR
(90 MINUTE RATED)
CHUTE BEYOND
FINISH FLOOR
CHUTE DOOR OPERATOR.
DOOR HANDLES ARE
REQUIRED TO BE
ACCESSIBLE PER CBC
CHAPTER 11
CHUTE
CHUTE HOPPER AT
DOOR BEYOND
B CHUTE SECTION AT CONCRETE FLOOR
SECTION B
FLOOR SLAB, SEE
STRUCTURAL DRAWINGS
VENTILATION SHAFT, SEE
MECHANICAL DRAWINGS
CAULK AIR TIGHT
UPPER GARAGE UPPER GARAGE
SHADED AREA INDICATES
CONCRETE FLOOR WITHIN
THE SHAFT AREA
1 HOUR RATED WALL
ASSEMBLY
TRASH DOOR PALM
PUSH BUTTON
2 HOUR RATED WALL
ASSEMBLY
2'-3" 2'-3" 2'-3"
M
A
X. 40"
MIN.
2'-0"
CHUTE DIAMETER
2'-0" WALL FINISH FACE
FLOOR SLAB OPENING
BELOW
FIRE SPRINKLER AT
EACH SHAFT AREA
A CHUTE PLAN AT CHUTE DOOR
SECTION D
SHAFT SHAFT SHAFT
2-HR RATED METAL
WALL ASSEMBLY
PROVIDE FURRING
HAT CHANNELS AS
REQUIRED
-
---
8" 4"
4"
4"
4"
24" DIAMETER TRASH
CHUTE
EXTERIOR GRADE PLYWOOD
WATERPROOFING PER
WATERPROOFING
DRAWINGS
GALVANIZED IRON SHEET
METAL FLASHING
SOLDERED TO TRASH
CHUTE, PER
WATERPROOFING
DRAWINGS
GALVANIZED SHEET METAL
FLASHING UPSIDE DOWN METAL
PAN. FIELD VERIFY DIMENSIONS
AND CONDITIONS SHOP
FABRICATE AND SOLDER ALL
SEAMS. BOTH ADJACENT WALL
CONDITION AND NON ADJACENT
CONDITIONS SHOWN PER
WATERPROOFING DRAWINGS
1/2" CEMENT BOARD
EXPLOSION PROOF CAP AS
REQUIRED
1' - 0" 2' - 0"
P
E
R
FLO
O
R/C
EILIN
G
A
S
S
E
M
BLY
PER WALL TYPE
.
PER WALL TYPE
T.O. PLATE
STRUCTURAL SHEATHING
AS OCCURS, SEE STRUCT
DWGS
PER WALL TYPE
.
---
-
24 GA. G.I. COPING. LAP
JOINTS 6" AND SEAL SPLICE.
PAINT TO MATCH ADJACENT
FINISH
P
E
R
R
O
O
F
A
S
S
E
M
BLY
T.O. PLATE
SLOPE 1% MIN. T.O.PARAPET
LEVEL 3
PER WALL TYPE
PER WALL TYPE
.
PODIUM SLAB. SEE
STRUCT DWGS
STRUCTURAL SHEATHING
AS OCCURS, SEE STRUCT
DWGS
GE SILICONES PENSIL 300 /
SPECIFIED TECHNOLOGIES
INC. PENSIL 300. MIN. 1 1/2"
THICK.
26 GA SHEET METAL LINER
AT MECHANICAL SHAFTS;
TEMINATE AT PODIUM SLAB
LEVEL 3
PER WALL TYPE
.
PODIUM SLAB. SEE
STRUCT DWGS
PER WALL TYPE
---
-
GE SILICONES PENSIL 300 /
SPECIFIED TECHNOLOGIES
INC. PENSIL 300. MIN. 1 1/2"
THICK.
26 GA SHEET METAL LINER
AT MECHANICAL SHAFTS;
TEMINATE AT PODIUM SLAB
GE SILICONE PENCIL 300 / SPECIFIED
TECHNOLOGIES INC. PENCIL 300 MIN.
1 1/2" THICK.
26 GA SHEET METAL COVER PLATE
26 GA SHEET METAL COVER PLATE
T.O. SHEATHING
PLYWOOD SHEATHING PER STRUCTURAL
(2) LAYERS OF 5/8" TYPE "X" GYPSUM
SHEATHING AT SHAFT. PROVIDE SINGLE
J-MOLD / J-MOLD AT EACH LAYER OF
GYPSUM SHEATHING
SHAFT
GE SILICONE PENCIL 300 / SPECIFIED
TECHNOLOGIES INC. PENCIL 300 MIN.
1 1/2" THICK.
26 GA SHEET METAL COVER PLATE
T.O. SHEATHING
P
E
R
FLO
O
R
A
S
S
E
M
BLY
(2) LAYERS OF 5/8" TYPE "X" GYPSUM
SHEATHING AT SHAFT. PROVIDE
SINGLE J-MOLD / J-MOLD AT EACH
LAYER OF GYPSUM SHEATHING
SHAFT
RENEWAL
DATE
RCHIT ECT
ED S NE IC L
A
ALI FOR N IA
O F E T AT S
C
JOHNNY C. LU
C-30396
6/30/2023
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1ST BUILDING DEPT SUBMITTAL 05-31-2022
5/31/2022 1ST PLAN CHECK
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt TRASH
CHUTE
ASSEMBLY
3/4" = 1'-0" 1 A7.40
TRASH CHUTE ASSEMBLIES WRAP
1" = 1'-0" 13 TRASH CHUTE TERMINATION AT ROOF
1 1/2" = 1'-0" 7
SHAFT WALL @ FLOOR / CEILING
1 1/2" = 1'-0" 8
SHAFT WALL @ ROOF
1 1/2" = 1'-0" 3
SHAFT WALL 1 @ PODIUM LEVEL
1 1/2" = 1'-0" 4
SHAFT WALL 2 @ PODIUM LEVEL
3" = 1'-0" 11
JOINT @ MECHANICAL SHAFT
3" = 1'-0" 12
JOINT @ 2-HR SHAFT
Date Issues / Revisions:
City Council 22 – 124 12/6/2022
OCCUP. SEPARATION / FIRE PARTITION (PARTY WALL)
AT 3RD FLOOR
PERPENDICULAR PARALLEL
OCCUP. SEPARATION / FIRE PARTITION (PARTY
WALL) AT 4TH TO 7TH FLOOR
OCCUP. SEPARATION / FIRE PARTITION (PARTY
WALL) AT ROOF
1-H
O
U
R
R
O
O
F
A
S
S
E
M
BLY
1HR- ASSEMBLY
A
S
S
E
M
BLY
1 H
R
FLO
O
R
C
EILIN
G
1 2 3 4 5 6 7 8 9 10 11 12 13 14
15 16 17 18 19 20
9 10
21 21
6 11
2 7
8 8
15 1
15 12
13 8
2 7
8 11
3 14
7 8
5 1
14 3-HOUR FIRE WALL AT 3RD FLOOR
NOTE: SEE BUILDING PLAN FOR LOCATIONS OF 3 HOUR FIRE WALLS 3-HOUR FIRE WALL AT 4TH TO 7TH FLOORS
1-H
R
FLR./CLG.
UNIT
PARALLEL JOIST
DIRECTIONS
UNIT UNIT
NOTE:
WALL AND FLOOR SYSTEM IS RATED
55-59 STC BY THE "GYPSUM ASSOC,
SOUND CONTROL MANUAL", ANY
OPENINGS IN THE CONSTRUCTION FOR
PIPING, ELECT. OUTLETS AND DEVICES,
ETC. SHALL BE SEALED, LINED,
INSULATED OR OTHERWISE TREATED
TO MAINTAIN THE REQUIRED RATING,
SEE SHEETS
NOTE:
3 HOUR FIRE WALL ASSEMBLY TO CONTINUE TO OUTER EDGES OF
PROJECTING ELEMENTS
CONDITION AT ROOF:
FIRE WALL TO EXTEND TO UNDERSIDE OF ROOF SHEATHING. ROOF FRAMING TO BREAK AT EITHER SIDE OF FIRE WALL.
PER 2019 CBC 706.6 EXCEPTION 2.2
NO OPENINGS ALLOWED
WITHIN 4'-0" OF EACH SIDE OF THE FIRE WALL
PER 2019 CBC 706.6 EXCEPTION 2.2
NO OPENINGS ALLOWED
WITHIN 4'-0" OF EACH SIDE OF THE FIRE WALL
3 - HOUR FIRE WALL AT ROOF LEVEL
IF
W
ALL E
X
C
E
E
D
S 10'-0"
P
R
O
VID
E
A
D
D'L. A
S
W
CLIP
S
AX.XX
-
ASSEMBLY
3HR FIREWALL
ASSEMBLY
3HR FIREWALL
ASSEMBLY
3HR FIREWALL
5 14
16 10
4 8
1 18
20 19
2 10
1 8
16 8
18 10
9 21
2 7
16 FOR INSULATION SCHEDULE, FIREBLOCKING, DRAFTSTOP & ACOUSTIC INSTALLATION REQUIREMENTS, SEE SHEET A7.01
SOUND CONTROL NOTES
COMMON VENTS OR DRAIN LINES IN PARTY WALL MAY BE CONNECTED IN STACKED UNITS.
ALL WATER SUPPLY LINES WITHIN THE PROJECT SHALL BE ISOLATED FROM
WOOD, METAL AND OTHER FRAMING WITH PIPE ISOLATORS SPECIFICALLY
MANUFACTURED FOR THAT PURPOSE AND APPROVED FOR USE BY THE DIRECTOR OF BUILDING AND SAFETY. ALL VERTICAL DRAINAGE LINES
WITHIN THE PROJECT SHALL BE ISOLATED FROM WOOD, METAL AND OTHER FRAMING.
PERIMETER CAULK ALL FOUR SIDES OF PARTY WALL DRYWALL
(TOP, BOTTOM, AND SIDES)
1. 2.
3. 4. FOR ADDITIONAL INFORMATION, SEE SHEET A-70.1
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1 ST PLAN CHECK SUBMITTAL 25% CD SET 05/31/2022
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt
DEMISING &
FIRE WALL
ASSEMBLIES
1 1/2" = 1'-0" 5 A7.41
1-HR FIRE PARTITION (DEMISING WALL)
1 1/2" = 1'-0" 9
3-HR FIREWALL-SECTION
12" = 1'-0" 1
NOTES - FIRE WALL
FIRE WALL NOTES
SYMBOL DESCRIPTION
1 ELEVATOR- PROVIDE 90 MINUTE FIRE RATED DOOR. * = WITH THE STRETCHER REQUIREMENTS OF BUILDING CODE 3002.4. PROVIDE STANDBY
POWER(UNDER SEPARATE PERMIT)
2 FUTURE STANDPIPE(CLASS I) LOCATION - SEE NFPA 13 FIRE SPRINKLER SYSTEM DWG'S. (DEFERRED SUBMITTAL)
3 LINE OF CANOPY ABOVE
4 LINE OF SOFFIT ABOVE
5 FIRE EXTINGUISHER- SEE NOTE M.2 ON SHEET GN-1 AND SPEC'S. 6 2-HR. RATED SHAFT- PROVIDE FIRE SPRINKLER AT TRASH CHUTE 7 ELECTRICAL/TELEPHONE
8 METAL RAILING SYSTEM- 42" A.F.F. MIN.
9 TRASH CHUTES - PROVIDE 90 MIN. DOORS AND FIRE SPRINKLERS 10 DRAFT / FIRESTOP: ONE LAYER 5/8" TYPE "X" GYPSUM BOARD 11 FIREBLOCK: BOTH VERTICAL AND HORIZONTAL AT 10'-0" O.C. MAX. SPACING.
FIRE BLOCK MATERIAL SHALL BE MINERAL FIBER, MINERAL WOOL, GLASS FIBER OR OTHER APPROVED NON-RIGID MATERIALS. (2019 CBC SECTION 718.2)
12 GYPSUM CONCRETE OVER STRUCTURAL PANEL SUB FLOOR
13 STRUCTURAL PANEL FLOOR DECK PER STRUCTURAL
14 WALL PENETRATION, SEE DETAILS ON SHEETS Ax.xx
15 FRAMING PER STRUCTURAL DRAWINGS
16 3-HOUR RATED FIRE WALL ASSEMBLY - SEE DETAIL AX.X
17 WHERE ROOF/CEILING FRAMING ELEMENTS ARE PERPENDICULAR TO THE
WALL, THE ENTIRE SPAN OF SUCH ROOF/CEILING FRAMING SHALL BE OF 1-HOUR FIRE-RESISTIVE CONSTRUCTION. THE FRAMING AND ELEMENTS
THAT SUPPORT THE ABOVE MENTIONED ROOF/CEILING FRAMING SHALL ALSO BE 1-HOUR CONSTRUCTION MINIMUM
18 PROVIDE ASW CLIPS AT 10'-0" O.C. VERTICALLY BETWEEN WOOD FRAMING AND "H" STUDS FOR WALLS UP TO 23'-0" HIGH SPAN. FOR WALLS UP TO 44'-0" HIGH SPAN, PROVIDE SAW CLIPS AT 5'-0" O.C. VERTICALLY BETWEEN WOOD FRAMING AND "H" STUDS, TYP. MEASURED FROM BOTTOM OF ROOF
SHEATHING
19 FIRE RETARDANT TREATED PLYWOOD- REFER TO STRUCT DRAWING FOR NAILING REQ.
20 HINGE POINT AT CONTINUOUS SEAM, TYP BOTH SIDES
21 WHERE ROOF/CEILING FRAMING ELEMENTS ARE PERPENDICULAR TO THE WALL,
THE ENTIRE SPAN OF SUCH ROOF/CEILING FRAMING SHALL BE OF 1-HOUR FIRE-RESISTIVE CONSTRUCTION. THE FRAMING AND ELEMENTS THAT
SUPPORT
THE ABOVE MENTIONED ROOF/CEILING FRAMING SHALL ALSO BE 1-HOUR CONSTRUCTION MIN.
X
Date Issues / Revisions:
City Council 22 – 125 12/6/2022
RENEWAL
DATE
RCHIT ECT
ED S NE IC L
A
ALI FOR N IA
O F E T AT S
C
JOHNNY C. LU
C-30396
6/30/2023
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1ST BUILDING DEPT SUBMITTAL 05-31-2022
5/31/2022 1ST PLAN CHECK
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt
STAIR DETAIL
A7.51
Date Issues / Revisions:
City Council 22 – 126 12/6/2022
RENEWAL
DATE
RCHIT ECT
ED S NE IC L
A
ALI FOR N IA
O F E T AT S
C
JOHNNY C. LU
C-30396
6/30/2023
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1ST BUILDING DEPT SUBMITTAL 05-31-2022
5/31/2022 1ST PLAN CHECK
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt
ELEVATOR
DETAIL
A7.52
Date Issues / Revisions:
City Council 22 – 127 12/6/2022
3'-6".
1'-7" 2'-8 1/2".
1'-7" 1'-0"
FLOOR
PIPE IN THE WALL
PER PLUMBING
FIRE HOSE VALVE
19"W x 19"H x 8
1/2"D WALL
OPENING
CENTERLINE OF
PIPE
EDGE OF WALL OPENIN G
RISER CLAMP
CABINET
EQUIPMENT
IDENTIFICATION
PER CBC 905.7.1
ABS OR PVC CLOSE FLANGE SIZED TO
ACCOMMODATE DRAIN PIPE. CLOSET
FLANGE SECURED TO PLYWOOD
SUBFLOOR WITH STEEL SCREWS
TOPPING PER SPECIFICATIONS
PLYWOOD SUBFLOOR PER STRUCTURAL
MIN. 3/4" DEPTH HILTI CP 606 FLEXIBLE
FIRESTOP SEALANT
NOMINAL 4" MAX. DIAMETER ABS
OR PVC PIPE
NOTE:
DIAMETER OF OPENING TO BE MAX. 1/4"
LARGER THAN OUTSIDE DIAMETER OF PIPE
REFERENCE: UL SYSTEM NO. F-C-2263
ROUND OR OVAL GAS
APPLIANCE B-VENT IN 1HR WALL
WALL ASSEMBLY
NO INSULATION PERMITTED IN
STUD & JOIST BAY WITH B-VENT
2 X WOOD STUDS WALL
FIRESTOP PLATE (PROVIDE TIGHT
FIT) ALL AROUND (FLOOR AND
CEILING LEVEL)
2X WOOD SILL PLATE CUT AWAY
FOR FULL WIDTH OF STUD BAY
FLOOR FRAMING PER
STRUCTURAL
PROVIDE 1" MIN. AIR SPACE TO ALL
COMBUSTIBLE MATERIALS
FIRE STOP SPACER NAILED TO
PLATE AT BOTH ENDS (FLOOR AND
CEILING LEVELS)
5/8" TYPE X GYPSUM BOARD EACH
SIDE TO PROVIDE ONE HOUR
ASSEMBLY
(2) 2X CONTINUOUS TOP PLATES,
CUT AWAY FOR FULL WIDTH OF
STUD BAY
NOTES:
1. PROVIDE WALL STUD SIZE TO FIT
VENT AND ALLOW 1" CLEAR
ANNULAR SPACE AROUND VENT TO
COMBUSTIBLE MATERIALS
2. INSTALL VENT PER
MANUFACTURER'S UL LISTING AND
INSTALLATION INSTRUCTIONS-UL
MH 5102
MECHANICAL DUCT
SHEET METAL PER
MECHANICAL
DRAWINGS AT
ASSEMBLY
SHEET METAL
EYEBROW VENT LAP
BUILDING PAPER PER
WATERPROOFING
DRAWINGS
FIRE CAULKING
TWO (2) LAYERS 5/8" TYPE
'X' GYPSUM WALLBOARD
LINED JOIST BAY AT
MECHANICAL VENT
V
E
RIF
Y
WIT
H
M
A
N
U
F
A
C
T
U
R
E
R
10" WID
E
X 25" HIG
H
CLE
A
R
1' - 4"
EXTERIOR CEMENT PLASTER OVER LATH OVER
WATERPROOFING PER WATERPROOFING
DRAWINGS (WHERE OCCURS)
CAULK CABINET TO OPENING AT ALL FOUR SIDES
SEMI-RECESSED FIRE EXTINGUISHER CABINET
SEE SPECIFICATIONS FOR REQUIREMENTS
5/8" TYPE 'X' GYPSUM BOARD
5/8" TYPE 'X' GYPSUM BOARD, NO JOINTS
WITHIN 8" OF FRAMED OPENING
1" THICK SHAFT LINER LAMINATE BOTH SIDES
OVER ENTIRE CONTACT SURFACE.
1/2" GYPSUM BOARD MINIMUM LAMINATE OVER
ENTIRE CONTACT SURFACE
FIRE EXTINGUISHER PER PLANS
FULL 2X4 BLOCKING - BOTH
SIDES, TOP AND BOTTOM
"J" MOLDING BOTH SIDES, TOP AND BOTTOM.
WHEN CABINET IS LOCATED LESS THAN 15'-0"
FROM FACE OF PROTECTIVE OVERHANG,
USE GI SHEET METAL DRIP FLASHING AT
HEAD CONDITION.
2X OR 3X STUDS AT 16" O.C.
2 1/4" MIN.
GA FILE NO. WP 1311
SOLID GYPSUM WALL
PIPE IN THE WALL PER
PLUMBING
1 LAYER OF 5/8"
GYPSUM BOARD
WALL OPENING REQUIRED
1'-7"
2x4 WOOD STUD
WALL
2x6 WOOD STUD
WALL
CABINET PER FIRE
SPRINKLER
DRAWINGS
8" MIN.
1'-8 1/4" 1'-7"
PLYWOOD SHEATING PER
STRUCTURAL
DRYER DUCT PER MECHANICAL
2X BLOCKING
DECK FRAMING PER STRUCTURAL
5/8" TYPE X GYPSUM BOARD
LINED JOIST BAY AT DRYER
VENT, SIM. TO DETAIL
J-MOLD AROUND OPENING
PAINT VISIBLE PORTION
OF DUCT BLACK
EXTERIOR CEMENT
PLASTER OVER METAL LATH
GRILLE PER
MECHANICAL
DRAWINGS
SHEET METAL GALVANIZED ROOF JACK
LAP ROOFING MEMBRANE OVER AND
UNDER BASE TO PROHIBIT WATER
ENTRY
ROOF ASSEMBLY PER DETAIL
2X BLOCKING BETWEEN
JOIST MEMBERS TYPICAL
26 GAUGE SHEET METAL DUCT
EXTERIOR PLASTER OVER MET. LATH AND
BUILDING PAPER PER WATERPROOFING
DRAWINGS
3/4"
.
1/2"
.
PARAPET HEIGHT FROM
TOP OF LOW ROOF
SHEATHING (ROOF
DATUM)
STRUCTURAL PLYWOOD AS REQ'D,
REFER TO STRUCT. DWGS.
EXT. CEM. PLAS. OVER MET. LATH
AND BLDG PAPER
T.O. ROOF SHEATHING
FIRE CAULKING
SOLID BLOCKING ON ALL FOUR SIDES
AROUND DUCT
SHOWER PER PLANS
(2) 5/8" TYPE 'X' GYPSUM BOARD FOR 1 HOUR WALL
DETAIL REQUIREMENTS PER C.B.C. TABLE
721.2.1.4(2)
FULL 2 X BLOCKING BETWEEN
JOISTS TO PROVIDE DRYWALL
NAILING SEE PLUMBING PLANS
WALL AS OCCURS
FOR PENETRATION OF
BLOCKING, SEE
CAST IRON WASTE LINE
AT PENETRATION OF
ONE HOUR ASSEMBLY
PER PLUMBING PLANS
CREMCO ICP/ICP NO HUB COUPLING.
UPC APPROVED FOR CAST IRON TO
PLASTIC CONNECTIONS IN CONCEALED
SPACES
PVC WASTE TRAP PER
PLUMBING PLANS
ALL PLASTIC TO PLASTIC PIPE
CONNECTIONS TO BE GLUE WELDED
DOUBLE PLYWOOD FLOOR CONSISTING OF MINIMUM 1/2"
(15/32") WOOD STRUCTURAL PANELS WITH EXTERIOR GLUE
OVER 5/8" (19/32") WOOD STRUCTURAL PANELS OR SUBFLOOR
OF (1) LAYER 1-1/8" T&G WOOD STRUCTURAL PANELS.
PER C.B.C. TABLE 720.1(3) 13.1.4
AX.XX
-
V
E
RIF
Y
WIT
H
M
A
N
U
F
A
C
T
U
R
E
R
10" WID
E
X 25" HIG
H
CLE
A
R
1' - 4"
EXTERIOR CEMENT PLASTER OVER LATH
OVER WATERPROOFING PER
WATERPROOFING DRAWINGS (WHERE
OCCURS)
CAULK CABINET TO OPENING AT
ALL FOUR SIDES
SEMI-RECESSED FIRE EXTINGUISHER
CABINET SEE SPECIFICATIONS FOR
REQUIREMENTS
2 LAYERS 5/8" TYPE 'X' GYPSUM BOARD
2 LAYERS 5/8" TYPE 'X' GYPSUM
BOARD, NO JOINTS WITHIN 24" OF
FRAMED OPENING
1" THICK SHAFT LINER LAMINATE BOTH
SIDES OVER ENTIRE CONTACT SURFACE.
1/2" TYPE 'X' GYPSUM BOARD MINIMUM
LAMINATE OVER ENTIRE CONTACT
SURFACE
FIRE EXTINGUISHER PER PLANS
FULL WIDTH BLOCKING - BOTH SIDES,
TOP AND BOTTOM
"J" MOLDING BOTH SIDES, TOP AND
BOTTOM. WHEN CABINET IS LOCATED
LESS THAN 15'-0" FROM FACE OF
PROTECTIVE OVERHANG, USE GI SHEET
METAL DRIP FLASHING AT HEAD
CONDITION.
2X OR 3X STUDS AT 16" O.C. GA FILE NO. WP 1841
SOLID GYPSUM WALL
1 HOUR RATED BOX
MODEL PER PLUMBING
DRAWINGS TO BE
INSTALLED IN
ACCORDANCE WITH W- L-7129 AND
MANUFACTURERS
INSTRUCTIONS.
PIPING PER PLUMBING /
MECHANICAL DRAWINGS
INSULATION PER SCHEDULE
5/8" TYPE X GYPSUM
WALLBOARD
2X SOLID WOOD BLOCKING
FIRE RATED ACCOUSTICAL
SEALANT
TOPPING PER
SPECIFICATION
S
NOMINAL 1 1/2" MAX.
SCHEDULE 40 ABS OR PVC
PIPE AND DRAIN FITTINGS
CEMENTED TOGETHER AND
PROVIDED WITH ABS OR
PVC BATHTUB
WASTE/OVERFLOW
FITTINGS.
PLYWOOD SUBFLOOR
PER STRUCTURAL
3/4" THICK PLYWOOD PATCH
SIZED TO OVERLAP
MINIMUM 2" BEYOND EACH
EDGE OF RECTANGULAR
OPENING. TWO PIECES
POSITIONED AROUND DRAIN
PIPING WITH CUT EDGES
TIGHTLY BUTTED, AND
SCREW ATTACHED TO
UNDERSIDE OF SUBFLOOR
WITH 1 1/4" LONG STEEL
SCREWS (SPACED MAXIMUM
6" O.C.). (SEE NOTE#3
BELOW)
MIN. 5/8" DEPTH HILTI CP 606
FLEXIBLE FIRESTOP
SEALANT FLUSH WITH BOTH
SURFACES OF PLYWOOD.
NOTES:
1. MAX. SIZE OF OPENING = 12"X8"
2. ANNULAR SPACE BETWEEN DRAIN PIPING AND PATH = MIN. 0", MAX. 1"
3. AS ALTERNATE TO PLYWOOD, 5/8" THICK GYPSUM WALL BOARD MAY BE USED.
REFERENCE: UL SYSTEM NO. F-C-2262
2" MIN.
1" MAX.
WALL PER
PLANS
2X FLOOR JOISTS
RECESSED DMF RATED
LIGHT FIXTURE ZERO
CLEARANCE RATED
BLOCK IN AREA
AROUND LIGHT
FIXTURE LOCATION,
THEN WRAP AREA W/
(2) 5/8" TYPE 'X' GYPSUM
BOARD
5/8" TYPE "X"
GYPSUM BOARD
FLOOR ASSEMBLY
FIRE RATED
ACOUSTICAL SEALANT
REQUIRED AT BLOCKIN TO CEILING BOARD
LIGHT FIXTURE RATING TO
MATCH ADJACENT FLOOR
CEILING ASSEMBLY.
FIRE RATED ACOUSTICAL
SEALANT
CONTRACTOR TO PROVIDE
SOUND TESTING RESULTS TO
ACCOUSTICAL CONSULTANT
PRIOR TO INSTALLATION
TRIM PER SPECIFICATIONS
2X FLOOR
JOISTS
RECESSED DMF RATED
LIGHT FIXTURE ZERO
CLEARANCE RATED
BLOCK IN AREA
AROUND LIGHT
FIXTURE LOCATION,
THEN WRAP AREA W/
(2) 5/8" TYPE 'X' GYP. BD.
5/8" TYPE 'X' MOLD
RESISTANT GYP. BD.
7/8" EXTERIOR
PLASTER OVER METAL
LATH WHERE OCCURS
AT EXTERIOR
CONDITION
2 1/2" METAL STUD
HVAC DUCT, PER
TENANT IMPROVEMENT
FIRE CAULKING PER
SPECIFICATIONS
2 1/2" METAL STUDS AT
16" O.C.
STRUCTURAL SLAB, SEE
STRUCTURAL
DRAWINGS
PENETRATING ITEM
2X OR 3X STUDS PER STRUCTURAL AT
16" O.C. MAXIMUM
WHERE WASTE AND WATER
SUPPLY PIPING IS REQUIRED IN
INTERIOR PARTITION WALLS, THE
PARTITION WALL SHALL BE
CONSTRUCTED WITH THE
FOLLOWING REVISIONS:
1. SNUGLY FITTING BETWEEN THE
STUDS WHERE PIPING OCCURS.
WALL TYPE PER PLAN
NOTE:
APPLY PLYWOOD PER STRUCTURAL
DRAWINGS TO STUDS PRIOR TO
APPLICATION OF FINISHES
PROVIDE 2x JOIST BAY BLOCK OR
5/8" TYPE "X" GYPSUM BOARD TO
ISOLATE WALL AND FLOOR
CAVITIES.
IF 2x BLOCKING ISOLATOR IS
USED A DRAFT STOP MUST BE
INSTALLED. PLYWOOD OR
INSULATION IS ACCEPTABLE
IF GYPSUM BOARD ISOLATOR IS
USED PENETRATIONS MUST BE
FIRE CAULKED
VERIFY SPECIAL PLAN CONDITIONS
0' - 2" TYP.
0' - 2 1/2"
PROVIDE 5/8" TYPE 'X'
GYPSUM BOARD
PROTECTION OF ALL
WALL ASSEMBLIES
PENETRATED
AIR HANDLER PER
MECHANICAL PLANS IN
DROPPED CEILING SPACE
FOR RETURN AIR ROUTING
AND ADDITIONAL
INFORMATION, SEE
MECHANICAL PLANS
OPENING
2 1/2" METAL STUD
1 5/8" METAL STUD
BATHROOM
LIGHT FIXTURE PER
ELECTRICAL DWGS.
NOTE:
WHEN LIGHT FIXTURE IS LOCATED IN A RATED CEILING A BOXED OUT AREA WRAPPED WITH 5/8" TYPE 'X' GYP. BOARD TO MATCH ADJ. FIRE RATING IS
REQUIRED
1 H
R
2 1/2" METAL STUD
7/8" EXTERIOR PLASTER AS
OCCURS
5/8" TYPE 'X' GYP.
BD.
FLOOR ASSEBMLY
FIRE RATED ACOUSTICAL SEALANT
FLEXIBLE HVAC DUCT
WRAP JOIST BAY WITH ONE
LAYER 5/8" TYPE X GYPSUM
WALLBOARD
5/8" TYPE 'X' GYPSUM BOARD AT
FLOOR JOISTS
2X FLOOR JOIST
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1 ST PLAN CHECK SUBMITTAL 25% CD SET 05/31/2022
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt
PENETRATION
ASSEMBLIES
1 1/2" = 1'-0" 1 A7.53
STANDPIPE AT CORRIDOR ELEVATION
1 1/2" = 1'-0" 2 WATER CLOSET WASTE LINE
1 1/2" = 1'-0" 3
B-VENT ASSEMBLY DETAIL
1 1/2" = 1'-0" 4
MECHANICAL VENT AT EXTERIOR WALL
3" = 1'-0" 5
1-HR RECESS FOR FIRE EXTINGUISHER
1 1/2" = 1'-0" 6
STANDPIPE AT CORRIDOR PLAN
3" = 1'-0" 8
EXHAUST DUCT AT DECK
1 1/2" = 1'-0" 9
EXHAUST FAN ROOF PENETRATION
1 1/2" = 1'-0" 7
SHOWER WASTE TRAP PENETRATION
3" = 1'-0" 10
2-HR RECESS FOR FIRE EXTINGUISHER
1 1/2" = 1'-0" 11
1-HR RATED BOX
1 1/2" = 1'-0" 12
BATHTUB WASTE TRAP DETAIL
1 1/2" = 1'-0" 13 RECESSED CAN LIGHT AT UNIT
1 1/2" = 1'-0" 14 FIRE-RATED LIGHT FXTR IN RATED CLG
1 1/2" = 1'-0" 15 RECESSED CAN LIGHT AT CORRIDOR
3" = 1'-0" 16 RETAIL SHAFT TERMINATION
1 1/2" = 1'-0" 17 FIRE STOPPING AT DUCT PNTRTNS
1 1/2" = 1'-0" 18 RETURN AIR LOCK BLOCKOUT
1 1/2" = 1'-0" 19 RECESSED LIGHT FIXTURE
1 1/2" = 1'-0" 20 1-HR HORIZONTAL DUCT CHASE
Date Issues / Revisions:
City Council 22 – 128 12/6/2022
1. PENETRATIONS IN WALLS REQUIRING PROTECTED OPENINGS MUST BE FIRE STOPPED WITH AN APPROVED MATERIAL IN ACCORDANCE WITH CBC SECTION 714. SPACE BETWEEN
PENETRATING MATERIALS MUST BE DESIGNED TO PREVENT THE MOVEMENT OF HOT FLAME OR GASES.
A. COPPER OR FERROUS PIPES OR CONDUITS MAY PENETRATE RATED WALLS OR
PARTITIONS PROVIDED THEY ARE FIRE-STOPPED WITH APPROVED FIRESTOPPING MATERIALS.
B. WHERE WALLS ARE PENETRATED BY OTHER MATERIALS OR WHERE LARGER OPENINGS
ARE REQUIRED THAN PERMITTED IN ITEM A ABOVE, THEY MUST BE QUALIFIED BY TESTS CONDUCTED IN ACCORDANCE WITH SECTION 703.2
2. MATERIALS USED IN THE FIRE SAFING SYSTEMS ARE TO BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S INSTRUCTIONS PROVIDED WITH THE MATERIALS AND SHALL BE UL LISTED AS FIRE RATED PRODUCTS.
3. THE F AND T RATINGS OF THROUGH PENETRATION FIRE STOPS SHALL NOT BE LESS THAN
THE FIRE RESISTANCE OF THE ASSEMBLY PENETRATED AND SHALL BE SUITABLE FOR THE METHOD OF, AND MATERIALS SURROUNDING THE PENETRATION AND PENETRATING ITEM.
4. FOR ADDITIONAL THROUGH PENETRATION AND MEMBRANE REQUIREMENTS, SEE CBC 714.
5. FIRE SAFING SYSTEMS ARE SPECIFIC FOR EACH VARYING CONDITION OF A FIRE RATED
WALL OR FLOOR ASSEMBLY, THE PENETRATING ITEM(S), AND THE MATERIALS SELECTED TO PREVENT THE SPREAD OF FIRE THROUGH THE PENETRATION. THE SAFING MATERIALS DESIGNATED FOR USE IN FIRE ASSEMBLIES ARE NOT PROVIDED SPECIFIC FIRE RATINGS.
SAFING MATERIALS SHALL BE SELECTED PER EACH MANUFACTURERS TECHNICAL
PRODUCT LITERATURE FOR EACH CONDITION ENCOUNTERED AND DOCUMENTED IN SHOP
DRAWINGS FOR REVIEW BY THE MANUFACTURER, CONTRACTOR, BUILDING DEPARTMENT AND ARCHITECT.
6. REVIEW FULL PLAN SET FOR THE CONSTRUCTION ASSEMBLIES AND PENETRATION DETAILS INCLUDING CONSULTING ENGINEERS DRAWINGS AND SPECS.
7. FOR DIFFERENT BUILDING CONSTRUCTION TYPES, SEE GEN SHEETS
8. PROVIDE SUBMITTALS PER SPECIFICATIONS WITH BUILDING DEPARTMENT APPROVALS FOR SPECIFIC PRODUCTS SUBMITTED.
9. ALL PENETRATING ITEMS PENETRATING FIRE RATED WALL OR FLOOR ASSEMBLIES ARE REQUIRED TO BE METAL. THE METAL PENETRATING ITEM MUST EXTEND 6" BEYOND EACH
SIDE OF THE ASSEMBLY BEFORE THE PENETRATING ITEM CAN CHANGE TO A NONMETALLIC MATERIAL. IF THE PENETRATING ITEM PENETRATES ONLY ONE SIDE OF A FIRE ASSEMBLY, THE PENETRATING ITEM MUST EXTEND 6" BEYOND THE EXTERIOR OF THE ASSEMBLY AND 6"
BEYOND THE PENETRATION WITHIN THE ASSEMBLY BEFORE THE PENETRATING ITEM CAN CHANGE TO A NONMETALLIC MATERIAL. ANY PROPOSED PENETRATION OF A FIRE RATED ASSEMBLY BY A NONMETALLIC PENETRANT MUST BE SUBMITTED FOR APPROVAL.
10. CONTRACTOR TO COMPARE PIPE MATERIAL WITH SOILS REPORT TO VERIFY COMPATIBILITY.
11. SMOKE AND FIRE DAMPERS MUST BE INSTALLED IN THE FOLLOWING LOCATIONS PER CBC 717.5.1 TO 717.5.7
A. DUCT PENETRATIONS OF AREA OR OCCUPANCY SEPARATION WALLS WITH RATINGS OF 2-HOURS OR LESS.
B. DUCTS PASSING THROUGH HORIZONTAL EXIT WALLS.
C. DUCTS PENETRATING SHAFTS (SEE CODE FOR EXCEPTIONS)
D. DUCTS PENETRATING FIRE RESISTIVE ELEMENTS OF FIRE RATED CORRIDOR WALLS. (EXCEPTION FOR STEEL DUCTS WITH NO OPENINGS TO CORRIDOR)
REFER TO MECHANICAL PLANS FOR LOCATIONS OF SMOKE FIRE DAMPERS
12. ALL PLUMBING PENETRATIONS THROUGH WALLS WHICH REQUIRE PROTECTION OF
OPENINGS (OCCUPANCY SEPARATION WALLS, FIRE WALLS, CORRIDOR WALLS OR WALLS
ADJACENT TO A REAL OR ASSUMED PROPERTY LINE) ARE REQUIRED TO BE GALVANIZED OR CAST IRON PIPING. SEE PLUMBING DRAWINGS.
13. PLASTIC ELECTRICAL BOXES SHALL BE CLEARLY IDENTIFIED AS APPROVED FOR THE FIRE RATED CONSTRUCTION PER CBC 714.
14. OPENINGS MADE THROUGH A FLOOR FOR PENETRATIONS SUCH AS CABLES, CABLE
TRAYS, CONDUIT, PIPES OR TUBING THAT ARE PROTECTED WITH APPROVED THROUGH
PENETRATION FIRE STOPS TO PROVIDE THE SAME DEGREE OF FIRE RESISTANCE AS THE FLOOR CONSTRUCTION NEED NOT BE ENCLOSED IN A SHAFT.
15. FOR PIPE PENETRATIONS THROUGH 3-HOUR CONCRETE PODIUM SLAB BETWEEN
GARAGE AND RESIDENTIAL OCCUPANCY, PROVIDE LISTED AND APPROVED FIRESTOPPING MATERIALS THAT MAINTAIN REQUIRED 3-HOUR RATED ASSEMBLY. CONTRACTOR SHALL
PROVIDE COMPLETE SUBMITTAL INFORMATION FOR FIRESTOPPING PRODUCTS FOR ALL SLAB PENETRATION CONDITIONS. SUBMITTAL SHALL BE REVIEWED BY THE ARCHITECT AND CONTRACTOR FOR SUBMITTAL TO THE CITY BUILDING DEPARTMENT FOR APPROVAL.
16. PRODUCTS SHALL BE LISTED WITH A RECOGNIZED TESTING AGENCY SUCH AS ICC, UL OR WARNOCK HERSEY. "OR EQUAL" MANUFACTURERS WILL BE CONSIDERED IF PROPER TESTING AGENCY APPROVALS ARE PROVIDED. OTHER MANUFACTURERS OF FIRE
STOPPING PRODUCTS MAY BE USED, PROVIDED THAT THE BUILDING DEPARTMENT APPROVALS ARE MET.
FILL ALL AROUND PENETRATING
ITEM WITH DRYWALL FIRECODE
COMPOUND TAPE AND SAND TO
FORM A COMPLETE SEAL TO
DRYWALL
IF ACOUSTICAL TREATMENT IS
REQUIRED PER PLANS, PROVIDE
AN ANNULAR SLEEVE AND USE
DETAIL
INSULATION AS REQUIRED
NOTES:
1. PROVIDE BLOCKING AS REQUIRED ABOVE PENETRATIONS
2. INTERRUPT INSULATION OUTSIDE PIPES AND DUCTS AT PENETRATIONS
3. AS FAR AS POSIBLE, SEPARATE PIPES, DUCTS AND CONDUITS SO THEY CAN BE TREATED INDIVIDUALLY AS ABOVE.
4. 2-HOUR WALL GRAPHICALLY SHOWN, 1- HOUR SIMILAR.
RIGIDLY SUPPORTED PIPE OR CONDUIT 2 INCHES OR LESS IN DIAMETER THRU DRYWALL OR PLASTER WALLS, FLOORS SIMILAR.
SEE GENERAL NOTES ON THIS
SHEET FOR ADDITIONAL
INFORMATION
TEST
ASSEMBLY:
UL # W-L-2093
F RATING - 1 AND 2 HR.
T RATING - 1 AND 1 1/2
HR.
5/8" MIN
A-75.2
4 FILL ALL AROUND PENETRATING ITEM
WITH DRYWALL FIRECODE COMPOUND
TAPE AND SAND TO FORM A
COMPLETE SEAL TO DRYWALL
FILL ANNULAR JOINT WITH FIRE
SAFING PER MANUFACTURES
REQUIREMENTS FOR FIRE RATING
REQUIRED PER PLANS. FIRE SAFING
SHALL BE COMPATIBLE WITH
SURROUNDING AND PENETRATING
MATERIALS.
INSULATION AS REQUIRED
NOTES:
1. PROVIDE BLOCKING AS REQUIRED ABOVE PENETRATIONS
2. INTERRUPT INSULATION OUTSIDE PIPES AND DUCTS AT PENETRATIONS
3. AS FAR AS POSSIBLE, SEPARATE PIPES, DUCTS AND CONDUITS SO THEY CAN BE TREATED INDIVIDUALLY AS ABOVE.
4. 2-HOUR WALL GRAPHICALLY SHOWN, 1- HOUR SIMILAR.
ALL RESILIENTLY SUPPORTED PIPES, DUCTS OR CONDUITS AND RIGIDLY- SUPPORTED PIPES, DUCTS OR CONDUITS OVER 2 INCHES IN DIAMETER THRU DRYWALL OR PLASTER WALLS, FLOORS SIMILAR.
METAL SLEEVE PROVIDED BY
TRADE OF PENETRATING ITEM
PROVIDE ACOUSTICAL SEALANT AS
REQUIRED PER PLANS. SEALANT
SHALL NOT DIMINISH FIRE SAFING
EFFECT FOR RATING REQUIRED.
M
A
N
U
F
A
C
T
U
R
E
R
0" MIN. - 2 3/8" M
A
X
V
E
RIF
Y
WIT
H
SEE GENERAL NOTES ON THIS
SHEET FOR ADDITIONAL
INFORMATION
TEST ASSEMBLY:
UL # W-L-1003
F RATINGS: 1 AND 2
HR.
T RATING: 0 HR.
FILL ALL AROUND PENETRATING
ITEM WITH DRYWALL FIRECODE
COMPOUND TAPE AND SAND TO
FORM A COMPLETE SEAL TO
DRYWALL
GROUT ALL ARROUND SLEEVE TO
FORM A COMPLETE SEAL TO
MASONRY
SEE STRUCTURAL PLANS FOR
C.M.U. WALL REQUIREMENTS
NOTES:
1. PROVIDE LINTELS AS REQUIRED ABOVE PENETRATIONS
2. INTERRUPT INSULATION OUTSIDE PIPES AND DUCTS AT PENETRATIONS
3. DO NOT GROUP DUCTS LIKE PIPES IN DETAIL
ELECTRICAL DUCT THRU DRYWALL OR PLASTER, MASONRY, OR CONCRETE FLOORS SIMILAR.
METAL SLEEVE PROVIDED BY
TRADE OF PENETRATING ITEM
PROVIDE ACOUSTICAL SEALANT AS
REQUIRED PER PLANS. SEALANT
SHALL NOT DIMINISH FIRE SAFING
EFFECT FOR RATING REQUIRED.
ELECTRICAL DUCT FILLED WIDTH
AND DEPTH OF PENETRATION
AFTER WIRES ARE PULLED. USE
EXPANDING FOAM FIRE SAFING
LISTED FOR USE WITH ELECTRICAL
COMPONENTS.
MINIMIZ
E
SEE GENERAL NOTES ON THIS
SHEET FOR ADDITIONAL
INFORMATION
THRU C.M.U. OR GYP. BD. CONST.
TEST ASSEMBLY:
UL # W-L-3065
FOR GYP BD
TEST ASSEMBLY:
UL # C-AJ-3320
FOR CMU
GYP BD WALL
AX.XX
X
UNFACED INSULATION ALL AROUND BOX
SHEET CAULKING ALL AROUND
BACK AND SIDES OF BOX
1/4" TO 1/2" JOINT FILLED WITH BEAD OF
3M -CP 25 N/S CAULK FACE FLANGE - DRYWALL OR PLASTER OVERLAPS FLANGE
NO UNUSED KNOCKOUTS OR
OTHER HOLES LEFT OPEN
ELECTRICAL OUTLET BOX SHALL BE OF
A MATERIAL APROVED FOR USE IN A 2- HOUR RATED ASSEMBLY (STEEL, PLASTIC) NOT EXCEEDING 16 SQ.
INCHES
0' - 2"
2'-0" MINIM
U
N
UNFACED INSULATION ALL AROUND BOX
SHEET CAULKING ALL AROUND
BACK AND SIDES OF BOX
1/4" TO 1/2" JOINT FILLED WITH BEAD OF
3M -CP 25WB N/S CAULK FACE FLANGE - DRYWALL OR PLASTER OVERLAPS FLANGE
NO UNUSED KNOCKOUTS OR OTHER
HOLES LEFT OPEN
IN DRYWALL
U465 1 HR - STEEL STUDS - NON BEARING WALL
U305 1 HR - WOOD STUDS - BEARING WALL
U301 2 HR - WOOD STUDS - BEARING WALL
NOTES:
1. PROVIDE LINTELS AS REQUIRED ABOVE PENETRATIONS
2. MAINTAIN INSULATION OUTSIDE OF PIPES AT PENETRATIONS
3. AS FAR AS POSSIBLE, SEPARATE PIPES, DUCTS AND CONDUITS SO THEY CAN BE TREATED INDIVIDUALLY AS ABOVE.
RIGIDLY SUPPORTED PIPE OR CONDUIT 2 INCHES OR LESS IN DIAMETER THRU C.M.U. OR CONCRETE WALLS, FLOORS SIMILAR.
FIRE RATED SEALANY ALL AROUND
PENETRATING ITEM TO FOAM A
COPLETE SEAL TO MASONRY
3" MAX OPENING, 2" MAX DIA. PIPE
IF ACOUSTICAL TREATMENT IS
REQUIRED PER PLANS, PROVIDE AN
ANNULAR SLEEVE AND USE DETAIL
SEE STRUCTURAL PLANS
FOR C.M.U. WALL
REQUIREMENTS.
TEST ASSEMBLY:
UL # C-AJ-1572
SEE GENERAL NOTES ON THIS
SHEET FOR ADDITIONAL
INFORMATION
AX.XX
X
1/4" MIN THK FIRE SEALANT
PROVIDE ACOUSTICAL SEALALANT
AS REQUIRED PER PLANS.
SEALALNT SHALL NOT DIMINISH
FIRE SAFING EFFECT FOR RATING
REQUIRED.
WRAP STRIP-ONE LAYER OF
INTUMESCENT WRAP STRIP WRAPPED
AROUND THE PIPE AND HELD INPLACE
W/ ALUMINUM TAPE
FILLED GROUT IN CMU, SEE
STRUCTURAL PLANS FOR C.M.U.
WALL REQUIREMENTS.
SEE GENERAL NOTES ON THIS
SHEET FOR ADDITIONAL
INFORMATION
TEST ASSEMBLY:
UL # C-AJ-2372
FILL ALL AROUND PENETRATING
ITEM WITH DRYWALL FIRECODE
COMPOUND TAPE AND SAND TO
FORM A COMPLETE SEAL TO
DRYWALL
GROUT ALL AROUND SLEEVE TO
FORM A COMPLETE SEAL TO
MASONRY
NOTES:
1. PROVIDE LINTELS AS REQUIRED ABOVE PENETRATIONS. 2. INTERRUPT INSULATION OUTSIDE PIPES AND DUCTS AT PENETRATIONS
3. DO NOT GROUP DUCTS LIKE PIPES IN DETAIL
MULTIPLE PIPES OR CONDUITS THRU DRYWALL OR PLASTER, MASONRY, OR CONCRETE FLOORS SIMILAR.
METAL SLEEVE PROVIDED BY
TRADE OF PENETRATING ITEM
PROVIDE ACOUSTICAL SEALANT AS
REQUIRED PER PLANS. SEALANT
SHALL NOT DIMINISH FIRE SAFING
EFFECT FOR RATING REQUIRED.
PENETRATING ELEMENTS
SEPARATED PER MANUFACTURERS
REQUIREMENTS
MINIMIZ
E
FILL ANNULAR JOINT WITH FIRE SAFING
PER MANUFACTURES REQUIREMENTS
FOR FIRE RATING REQUIRED PER PLANS.
FIRE SAFING SHALL BE COMPATIBLE WITH
SURROUNDING AND PENETRATING
MATERIALS.
TEST ASSEMBLY
UL # W-L-8056
SEE GENERAL NOTES ON THIS
SHEET FOR ADDITIONAL
INFORMATION
THRU C.M.U. OR GYP. BD. CONST.
A-75.2
5 SEE PLANS FOR RATING REQUIRED.
ONE LAYER 5/8" TYPE 'X' DRYWALL AT ONE
HOUR RATING. TWO LAYERS REQUIRED AT
TWO HOUR RATING. SEAL AIR TIGHT.
CONSTRUCT OPENING PRIOR TO
INSTALLATION OF FIXTURE
UNFACED INSULATION ALL AROUND
NO UNUSED KNOCKOUTS OR OTHER HOLES
LEFT OPEN
ACOUSTICAL SEALANT ALL AROUND
PERIMETER
SEAL ANY CONDUIT AT BOX BACKING
PENETRATION
NOTE:
2HR WALL GRAPHICALLY, 1HR TO BE SIMILAR.
ELECTRICAL BOX OVER 4" X 8" CABINET, FIXTURE, ACCESSORY IN DRYWALL OR PLASTER.
PROVIDE THROUGH PENETRATION
FIRESTOP AND FIREBLOCKING PER
CBC SECTION 714.3.1.2 AND 718.2
ELECTRICAL AND FIRE EXTINGUISHER
CABINETS SHALL HAVE THE SAME FIRE
RATING AS THE WALL
MINIMUM 3" SOLID BACKING
GROUT ALL AROUND AND BEHIND BOX
SEAL ANY CONDUIT AT BOX BACKING
PENETRATION
NOTE:
ELECTRICAL BOX OVER 4" X 8" CABINET,
FIXTURE, ACCESSORY IN MASONRY WALL
FIRE STOP
CAULKING
MINERAL
WOOL
CAULKING
STEEL
SLEEVE
COPPER OR
STEEL PIPE
SECTION
PLAN
FIRE STOP
CAULKING
MINERAL
WOOL
CAULKING
MINERAL
FIBER PIPE
INSULATION
COPPER
TUBING
SECTION
PLAN
CONCRETE
SLAB ( SEE
STRUCTURAL)
C- STEEL OR COPPER
PIPE
B- COPPER TUBING A- STEEL PIPE, CAST IRON OR CONDUIT
FOR PENETRATION SUBMITTAL
REQUIREMENTS, SEE FIRE STOPPING NOTE
15 IN
FIRE STOP
CAULKING
FOAM BACKING
STEEL PIPE OR CONDUIT
SECTION
PLAN
CONCRETE
SLAB ( SEE
STRUCTURAL)
CONCRETE
SLAB ( SEE
STRUCTURAL)
A-75.2
1 PIPING ISOLATOR OF MINIMUM 1/2"
THICK FELT OR 1" THICK PIPING
INSULATION JACKET
ADJUSTABLE RING HANGER WITH
FELT LINING
SECURE WIRE FIRST AND
PLASTER
TO WIRE EXTENDED THRU
LATH OR DRILL HOLE IN
DRYWALL FOR WIRE
CLOSE ANY OPENING WITH
ACOUSTICAL SEALANT
HANGER WIRE THRU DRYWALL
OR PLASTER CEILING
DRYWALL
CEILING
PLASTER
CEILING
MAX. 3/8"
PIPE ON ROD HANGER
FELT LINED METAL SLEEVE
FITTED TIGHTLY TO HANGER
ACOUSTICAL SEALANT
DRYWALL
CEILING
PLASTER
CEILING
DRILL HOLE IN PLASTER OR
DRYWALL AND FILL WITH
ACOUSTICAL SEALANT
BEFORE INSERTING AND
TIGHTENING MOLLY BOLT
DRYWALL
PLASTER
VERIFY WEIGHT OF ITEM TO BE FASTENED WITH THE BOLTS WEIGHT RATING.
ITEMS OVER 20 POUNDS OR INTENTED TO SUPPORT STRUCTURAL IMPOSED LOADS SHALL BE FASTENED INTO SOLID BLOCKING WITH ANCHORS.
WALL SURFACE FINISH MOUNTED FOR ELEMENT
STEEL DUCT-NOMINAL 32"x32"x NO.24 GA. (OR
HEAVIER) GALVANIZED STEEL DUCT. ONE
STEEL DUCT TO BE POSITIONED WITHIN THE
FIRESTOP SYSTEM. THE ANNULAR SPACE
SHALL BE MIN 1/2" TO MAX. 1 1/2". DUCT TO BE
RIGIDLY SUPPORTED ON BOTH SIDES OF
FLOOR OR WALL ASSEMBLY.
STEEL RETAINING ANGLE - NOMINAL 2"x2"x
NO. 16 GA. (OR HEAVIER) STEEL ANGLES
ATTACHED TO ALL FOUR SIDES OF THE
STEEL DUCT ON THE TOP SURFACE OF THE
WALL. THE ANGLES SHALL BE ATTACHED
WITH NO.8 (OR LARGER) STEEL SHEET
METAL SCREWS SPACED MAX OF 1" FROM
EACH AND AND A MAX. OF 3" O.C.
FIRESTOP SYSTEM - THE FIRESTOP SYSTEM
SHALL CONSIST OF THE FOLLOWING:
PACKING MATERIALS - MIN. 3 1/2" THICKNESS
OF MIN. 4 PCF MINERAL WOOL BATT
INSULATION FIRMLY PACKED INTO OPENING AS
A PERMANENT FORM BETWEEN THE BARE
STEEL DUCT AND THE PERIPHERY OF THE
OPENING. PACKING MATERIAL TO BE
RECESSED FROM TOP SURFACE OF FLOOR OR
BOTH SURFACES OF WALL AS REQUIRED TO
ACCOMMODATE THE REQUIRED THICKNESS OF
FILL MATERIAL.
FILL, VOID OR CAVITY MATERIAL - SEALANT - MIN 1 IN. THICKNESS OF FILL MATERIAL APPLIED
WITHIN THE ANNULUS, FLUSH WITH TOP
SURFACE OF FLOOR OR WITH BOTH SURFACES
OF WALL.
HILTI CONSTRUCTION CHEMICALS CP 601S
ELASTOMERIC FIRESTOP SEALANT OR CP604
SELF LEVELING FIRESTOP SEALANT.
FLOOR OR WALL ASSEMBLY-MIN. 4 1/2" THICK
REINFORCED CONCRETE FLOOR OR MIN. 5 1/2"
THICK LIGHTWEIGHT OR NORMAL WEIGHT
CONCRETE WALL.
REFERENCE:
UL DESIGN # C-AJ-7046
3 HOUR FIRE RATING
PARTITION - PER PLAN
FLOOR FINISH- PER FINISH
SCHED.
FLOOR SYSTEM
PER STRUCTURAL
2 1/2" MTL STUD 16" O.C. W/ 5/8"
GWB TYPE 'X' ONE SIDE
VERIFY W/ PLAN
0' - 11 15/16"
ELECT. ROOM
TOILET
12"Wx4"HxL(VARIES) OR AS
RQD 24 GA GALV. STEEL DRIP
PAN
3/4" PVC DRAIN PIPE
PLUMBING LINES- PER PLUMBING
FILL ANNULAR SPACE AROUND VENT
AT FLOOR OR CEILING WITH NONCOMBUSTIBLE MATERIAL (FIRE
SAFING)
EXTERIOR CEMENT PLASTER
GAS BURNING APPLIANCE
VENT IN 1-HR WALL ASSEMBLY
NOTE:
GAS VENTS AND NON-COMBUSTIBLE
PIPING PASSING THROUGH THREE
FLOORS OR LESS
A - INTERIOR WALL
B - EXTERIOR WALL
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1 ST PLAN CHECK SUBMITTAL 25% CD SET 05/31/2022
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt
PENETRATION
ASSEMBLIES
12" = 1'-0" 1 A7.54
GENERAL NOTES
3" = 1'-0" 3
2" MAX PENETRATION THRU GYP BD
3" = 1'-0" 4
2" MIN PENETRATION THRU G.B. CONST.
3" = 1'-0" 5
ELECTRICAL DUCT PENETRATION
3" = 1'-0" 6
STAG PEN. AT 2-HR PARTY WALL
3" = 1'-0" 7
ELECTRICAL BOX UP TO 16 SQ. IN.
3" = 1'-0" 8
2" MAX PENETRATION THRU CMU WALL
3" = 1'-0" 9
2" MIN PENETRATION THRU CMU WALL
3" = 1'-0" 10
PIPE PENETRATION AT DRYWALL
3" = 1'-0" 11
FIXTURE PENETRATION IN RATED WALL
3" = 1'-0" 12
FIXTURE PEN. IN RATED CMU WALL
1" = 1'-0" 13 FIRE STOPPING AT 3-HR PODIUM SLAB
6" = 1'-0" 14 SUSPENDED PIPE HANGER
3" = 1'-0" 15 NON - RATED HANGER PEN AT CLG
3" = 1'-0" 16 NON-STRUCTURAL MOLLY BOLT THRU
1" = 1'-0" 18 MECHANICAL DUCT PENETRATION
1" = 1'-0" 19 PLUMB. PENETRATION AT ELEC. RM
3" = 1'-0" 20 NON - COMBUSTIBLE PIPE AT WALL
Date Issues / Revisions:
City Council 22 – 129 12/6/2022
ALTERNATE TO SPRAY-ON FIREPROOFING:
TYPE "X" GYP. BOARD FIRE PROTECTION ON
STEEL. REFER TO 2013 CBC 721.5.2.2
SPRAY APPLIED FIRE PROTECTION @ COLUMN:
GRACE CONSTRUCTION PRODUCTS "MONOKOTE MK-6"
THERMAL BARRIER, OR EQUAL
I.C.C. REPORT ESR-1186
OR
ISOLATEK INTERNATIONAL "CAFCO SPRAYFILM WB-3" &
"WB-5" INTUMESCENT FIRE RESISTIVE COATING, OR
EQUAL
I.C.C. REPORT ESR-1092
SPRAY APPLIED FIRE PROTECTION @ BEAM:
ISOLATEK INTERNATIONAL "CAFCO SPRAYFILM WB-3" &
"WB-5" INTUMESCENT FIRE RESISTIVE COATING, OR
EQUAL
I.C.C. REPORT ESR-1092
NOTES:
STRUCTURAL COLUMNS PER CBC 722.5.1.1
HORIZONTAL STRUCTURAL MEMBERS WHICH SUPPORT A LOAD OF MORE THAN ONE STORY REQUIRE AN ADDITIONAL FIRE PROTECTION PER CBC 722.5.2.
SEE STRUCTURAL PLANS FOR STEEL BEAM AND COLUMN SIZES AND LOCATIONS
VERIFY ALL COATING THICKNESS REQUIREMENTS WITH COATING MANUFACTURER
SPECIAL INSPECTION IS REQUIRED FOR ALL SPRAYED APPLIED FIRE PROTECTION
FOR FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS, SEE SHEET
1. 2.
3. 4.
5. 6.
BASE LAYER 1/2" (MIN.) TYPE "X"
GYPSUM WALLBOARD APPLIED AROUND
W10X49 (MINIMUM) COLUMN AND HELD
IN PLACE WITH PAPER MASKING TAPE.
FACE LAYER EITHER NO. 24 MSG
GALVANIZED STEEL COLUMN COVER
CONSISTING OF TWO L-SHAPED
SECTIONS WITH SNAP-LOCK SHEET
STEEL JOINTS OR NO. 22 MSG
GALVANIZED STEEL COLUMN COVERS
CONSISTING OF TWO L-SHAPED
SECTIONS WITH LAP JOINTS FASTENED
WITH NO. 8x1/2" SHEET METAL SCREWS
12" O.C.
REF GA FILE NO CM 1000
FOR 1 HOUR FIRE RATING
CL
CL
PER PLAN
UNIT WALL PER PLAN
2X PLUMBING WALL WHERE OCCURS
FLOOR JOIST PER STRUCTURAL
2x NAILER PER STRUCTURAL
EXTERIOR CEMENT PLASTER OVER
EXPANDED METAL LATH OVER BUILDING
PAPER PER WP DWGS
FINISH FLOOR AT UNIT
TOP OF GYPCRETE
PLATE HEIGHT
2 LAYERS OF 5/8" TYPE "X" GYPSUM
BOARD
CL
2X BLOCKING AS REQUIRED
STEEL BEAM PER STRUCTURAL
INTUMESCENT FIRE RESISTIVE COATING ALL
AROUND BEAM INCLUDING TOP.
ISOLATEK INTERNATIONAL "CAFCO SPRAYFILM
WB-3" & "WB-5" INTUMESCENT FIRE RESISTIVE
COATING OR EQUAL
I.C.C. REPORT ESR-1092
UNIT WALL PER PLAN
2X PLUMBING WALL WHERE OCCURS
3x NAILER PER STRUCTURAL
EXTERIOR CEMENT PLASTER OVER
EXPANDED METAL LATH OVER
BUILDING PAPER PER WP DWGS
FINISH FLOOR ATA UNIT
TOP OF GYPCRETE
PLATE HEIGHT
PER PLAN
2 1/2" METAL STUD FRAMING
CEILING HEIGHT
PER PLAN
2" X 2" X 20 GA METAL ANGLE
INTUMESCENT FIRE RESISTIVE COATING ALL
AROUND BEAM INCLUDING TOP.
ISOLATEK INTERNATIONAL "CAFCO SPRAYFILM
WB-3" & "WB-5" INTUMESCENT FIRE RESISTIVE
COATING OR EQUAL
I.C.C. REPORT ESR-1092
STEEL BEAM PER STRUCTURAL
CL
3x WOOD NAILER PER STRUCTURAL
7/8" EXTERIOR PLASTER OVER
EXPANDED METAL LATH PER WP DOCS
1-H
O
U
R
A
S
S
E
M
BLY
FLOOR JOISTS PER
STRUCTURAL DRAWINGS
FINISH FLOOR
PLATE HEIGHT
METAL CEILING JOISTS AT BREEZEWAY
CEILING
CENTERLINE OF STEEL FRAME PER
ENLARGED PLANS
SEE BUILDING/WALL SECTION FOR
SOFFIT AND CEILING HEIGHT
2 LAYERS OF 5/8" TYPE "X"
GYPSUM BOARD
CL
2 X BLOCKING AS REQUIRED
INTUMESCENT FIRE RESISTIVE COATING ALL
AROUND BEAM INCLUDING TOP.
ISOLATEK INTERNATIONAL "CAFCO
SPRAYFILM WB-3" & "WB-5" INTUMESCENT
FIRE RESISTIVE COATING OR EQUAL
I.C.C. REPORT ESR-1092
STEEL BEAM PER STRUCTURAL
3x WOOD NAILER PER STRUCTURAL
7/8" EXTERIOR PLASTER OVER
EXPANDED METAL LATH PER WP
DWGS
1-H
O
U
R
A
S
S
E
M
BLY
FLOOR JOISTS PER STRUCT DWGS
FINISH FLOOR
PLATE HEIGHT
METAL CEILING JOISTS AT
BREEZEWAY CEILING
CENTERLINE OF STEEL FRAME
PER ENLARGED PLANS
FOR SOFFIT AND CEILING HEIGHT
SEE BUILDING/WALL SECTION
CEILING HEIGHT
CL
2" X 2" X 20 GA. METAL ANGLE
INTUMESCENT FIRE RESISTIVE
COATING ALL AROUND BEAM
INCLUDING TOP.
ISOLATEK INTERNATIONAL "CAFCO
SPRAYFILM WB-3" & "WB-5"
INTUMESCENT FIRE RESISTIVE
COATING OR EQUAL
I.C.C. REPORT ESR-1092
STEEL BEAM PER STRUCTURAL
CENTERLINE OF COL.
TUBE STEEL COLUMN, PER
STRUCTURAL
SECTION
PLAN
FIREPROOFING ON
STEEL BEAM
MIN 1" THICK
CENTERLINE OF COLUMN
TUBE STEEL
COLUMN, SEE
STRUCTURAL
DRAWINGS
STEEL BEAM, PER
STRUCTURAL
3X NAILER PER
STRUCTURAL
PLYWOOD SHEATHING
SPRAY FIREPROOFING
ON METAL STUD.VERIFY
THICKNESS WITH
MNUFR.
KNIFE PLATE, PER
STRUCTURAL
SPRAY FIREPROOFING
FIREPROOFIN
G OVER
STEEL PLATE
& BOLTS
AS REQ,D.
SPRAY FIREPROOFING
THICKNESS WITH THE
MNUFR
MIN. 1" THICK PER
ACOUSTIC
CONSULTANT
TOP OF SHEATHING
STEEL BEAM PER
STRUCTURAL
FLOOR CEILING ASSEMBLY
JOIST HANGER
SPRAY FIREPROOFING
THICKNESS 1" MIN.
2 LAYERS OF GYP BD
ATTCHED TO RC
CHANNELS TYP
FLOOR JOISTS PER
STRUCTURAL DRAWINGS
FINISH FLOOR
2 1/2" METAL STUDS
2 LAYERS OF 5/8" TYPE "X"
GYPSUM BOARD
CL
STEEL BEAM PER STRUCTURAL
DRAWINGS
WOOD NAILER PER
STRUCTURAL DRAWINGS
WOOD BLOCKING PER
STRUCTURAL DRAWINGS
SEE ACCOUSTICAL REPORT
FOR ADDITIONAL
REQUIREMENTS
FIRE RATING: TWO HOUR
IIC:
ASSEMBLY: CBC 721.1 (1) 2-4.1
LOAD BEARING WALL
PER STRUCTURAL
HORIZONTAL STRUCTURAL MEMBERS (BEAMS)
SHALL BE INDIVIDUALLY WRAPPED W/ 5/8" TYPE
'X' GYP. BD. WHEN THE MEMBER SUPPORTS
DIRECTLY APPLIED LOADS FROM A FLOOR AND
ROOF OR MORE THAN TWO FLOORS PER 2013
CBC 704.3
FIRE RATED ACOUSTICAL
SEALANT
NOTE:
SEE ALL STRUCTURAL SHEETS FOR
BEAM SIZE AND LOCATIONS
FINISH FLOOR
5/8" TYPE 'X' GYPSUM WALL BOARD
WOOD BEAM PER STRUCTURAL DRAWINGS
EXPOSED BEAM
FLOOR CEILING ASSEMBLY
JOIST HANGER
SPRAY FIRE PROOFING OVER THE BEAM
BEYOND SHOWN DASHED. THICKNESS
MIN 1" TYPICAL
BOTTOM OF THE BEAM
SHOWN DASHED
2 LAYERS OF GYP BD
ATTACHED TO RC
CHANNEL TYPICAL
TOP OF SHEATHING
STEEL BEAM PER
STRUCTURAL
3X NAILER, SEE
STRUCTURAL
DRAWINGS
FLOOR CEILING ASSEMBLY
JOIST HANGER
SPRAY FIREPROOFING
SHEET METAL ANGLE TO
SUPPORT GYP BD
SPRAY FIREPROOFING.
THICKNESS 1" MIN
SPRAY FIREPROOFING.
THICKNESS 1" MIN
2 LAYERS OF GYP BD
ATTCHED TO RC
CHANNELS TYP
AT SHEAR WALLS
A
TUBE STEEL COLUMN, PER
STRUCTURAL
2 LAYERS OF 1/2" TYPE "X" GYP
BOARD ADHESIVELY* SECURED TO
COLUMN FLANGES AND SUCCESSIVE
LAYERS. WALLBOARD APPLIED
WITHOUT VERTICAL JOINTS. CORNER
EDGES OF EACH LAYER
STAGGERED. FOR 1-HOUR FIRE
PROTECTION OF TUBE STEEL PER
CBC TABLE 720.1
REFERENCE C.B.C
TABLE 721.1 (1) ITEM NUMBER 1-7.1
AT NON-SHEAR WALLS
B
WALL PER PLAN
TUBE STEEL COLUMN, PER
STRUCTURAL
2 LAYERS OF 1/2" TYPE "X" GYP
BOARD ADHESIVELY* SECURED TO
COLUMN FLANGES AND SUCCESSIVE
LAYERS. WALLBOARD APPLIED
WITHOUT VERTICAL JOINTS. CORNER
EDGES OF EACH LAYER
STAGGERED. FOR 1-HOUR FIRE
PROTECTION OF TUBE STEEL PER
CBC TABLE 720.1
2X NAILER ATTACHED TO TUBE
STEEL WITH THREADED NELSON
STUD
WALL PER PLAN
ALTERNATE DETAIL AT
EXTERIOR SHEAR WALL
ONLY
C
TUBE STEEL COLUMN, PER
STRUCTURAL
INTUMESCENT COATING
PER UL Y616 (1HR CONDITION)
2X NAILER ATTACHED TO TUBE
STEEL WITH THREADED NELSON
STUD
WALL PER PLAN
2HR DETAIL AT CORNER
CONDITION ONLY
D
TUBE STEEL COLUMN, PER
STRUCTURAL
INTUMESCENT COATING
PER UL Y616 (2HR CONDITION)
EXTERIOR CEMENT
PLASTER
*AN APPROVED ADHESIVE QUALIFED
UNDER ASTM EL 19 OR UL 263.
*AN APPROVED ADHESIVE QUALIFED
UNDER ASTM EL 19 OR UL 263.
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1 ST PLAN CHECK SUBMITTAL 25% CD SET 05/31/2022
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt FIRE
PROOFING
DETAILS
12" = 1'-0" 1 A7.55
SPRAY APPLIED FIRE PROTECTION @
STEEL
1 1/2" = 1'-0" 2
1-HR GYPSUM BOARD COLUMN
PROTECTION
1 1/2" = 1'-0" 5
1-HOUR DROPPED BEAM PROTECTION
1 1/2" = 1'-0" 6
1-HR BEAM PROTECTION
1 1/2" = 1'-0" 7
1-HR DROPPED BEAM WITH SOFFIT
1 1/2" = 1'-0" 8
1-HR BEAM PROTECTION WITH SOFFIT
1 : 5 9
STEEL COLUMN & BEAM PROTECTION
1 : 5 11
BEAM W/O NAILER @ FLOORING/CLG ASSY
1 1/2" = 1'-0" 12
2-HR DROPPED BEAM
1 1/2" = 1'-0" 13 *1-HR PROTECTION AT BEAM
1 1/2" = 1'-0" 14 1-HR PROTECTION AT WOOD BEAM
3" = 1'-0" 3
STEEL BEAM INTERFACE WITH FLOOR/CLG
1 : 5 4
BEAM INTERFACE WITH FLOOR/CLG ASSY
3" = 1'-0" 17 1-HR COLUMN PROTECTION AT WALL
Date Issues / Revisions:
City Council 22 – 130 12/6/2022
PLYWOOD LAYER OVER WOOD-FRAMED ROOF STRUCTURE - SLOPE TO DRAIN 1/2" PER FOOT PLAN
T.O. ROOF
2 SHEATHING
".
3". 3".
1 1/2".
2".
1'-2". 1'-8". 1'-2".
3". 4'-0". 3".
3". 2'-0". 3".
ROOF DRAIN ASSEMBLY
PROVIDE ROOFING
PLYWOOD PER STRUCT.
OVERFLOW ROOF DRAIN ASSEMBLY
WOOD BLOCKING AS NECESSARY FOR ADEQUATE STRUCTURAL
SUPPORT
BUILT-UP ROOFING
PAN FLASHING - SECURE
OUTSIDE SUMP
W/ FLUSH HEAD SCREWS
SEE STRUCT. DWGS FOR
PLYWOOD INFO
NOTE: SEE PLUMBING
DRAWINGS
FOR ADDITIONAL
INFORMATION
PAN FLASHING - SECURE OUTSIDE SUMP W/
FLUSH HEAD SCREWS
DRAIN BODY FABRIC FLASHING PER WP
DOCUMENTS - COVER W/ PROTECTION COAT
MATERIALS
DRAIN RECEIVER
- SECURE @ 4" O.C. W/ FLUSH HEAD
SCREWS
BUILT-UP ROOFING
NOTES:
1. STEEL CLAMPING RINGS MUST BE USED ON ALL ROOF AND OVERFLOW DRAINS.
2. IF THE DRAIN SUMP IS RECESSED BELOW THE DECK MORE THAN FOUR INCHES,
PLYWOOD OR WOOD CANT STRIP SHALL BE INSTALLED TO MEET FLUSH WITH THE TOP OF THE SUMP.
THE PLYWOOD CANT SHALL BE INSTALLED AT A 45 DEGREE ANGLE, WITH THE TOP AND BOTTOM EDGES MITERED TO FIT FLUSH WITH THE SUBSTRATE.
3. AFTER COMPLETE INSTALLATION OF THE ROOF SYSTEM, CONTRACTOR SHALL
INSPECT AND
TEST ALL ROOF DRAINS TO ASSURE THAT NO CLOGGING OF THE DRAINAGE SYSTEM IS PRESENT. THE ROOF DRAIN LEADER SHOULD BE IN SUCH CONDITION THAT THE FULL DIAMETER OF THE DRAIN LEADER IS CLEAR.
HEAT VENT PIPE
8" .
ELASTOMERIC SEALANT
24 GA. G.I. PIPE FLASHING - SET
FLANGE INTO A FULL BED OF ROOF
CEMENT OVER SPECIFIED FELTS.
NAILS AT 4" O.C., STAGGERED
ROOF CEMENT WITH ALUMINUM COATING
FLASHING ASSEMBLY
BUILT-UP ROOFING ASSEMBLY - REFER TO W.P. PLANS FROM
INFOMATION
SUBSTRATE
STAINLESS STEEL SCREW CLAMP
24 GA. G.I. UMBRELLA HOOD
NOTES:
1. SURFACES TO RECEIVE SEAL TAPE SHALL BE THOROUGHLY CLEAN AND DRY
2. ALL SEAMS ARE TO BE LEAD SOLDERED
3. USE 3/8" HEAD NAILS, SPACED AT 4" O.C. AND STAGGERED FOR SECUREMENT OF METAL FLANGE TO PLYWOOD DECK.
4" .
FRONT VIEW - NTS
MIN. CLEAR
2' - 0"
ALL SEAMS SHALL HAVE
A
CONTINUOUS WELD ISOMETRIC VIEW - NTS AT FLANGE
LAP UPPER AND LOWER
HALVES
WITH TOP HALF ON
OUTSIDE
24 GA. GALV SHEET METAL
MULTIPLE PIPE ENCLOSURE
- SET FLANGE IN ROOF
CEMENT
OVER INTERPLY FELTS AND
FASTEN TO DECK USING
3/8" HEAD NAILS
STAGGERED AT 3" O.C.
SHEET METAL
SCREWS - MINIMUM 2
PER SIDE
ROOF CEMENT WITH
ALUMINUM COATING
SPECIFIED FLASHING
ASSEMBLY
ROOFING MEMBRANE
SUBSTRATE
HIGH-LOW COMBUSTION
VENTS FROM MULTIPLE LEVELS
B-VENT
MIN.
0' - 8"
0' - 6"0' - 4 3/256"
BALLOON FRAME PARAPET WALLS
AT PERMETER PER STRUCT. DWGS.
SLOPE
GALV. SHEET METAL PARAPET CAP
ROOF FRAMING PER
STRUCTURAL
6" STRIP OF MOISTSTOP PAPER LAP
SHINGLE STYLE WITH BUILDING PAPER
EACH SIDE OF PAPAPET
EXTERIOR PLASTER OVER BUILDING
PAPER AND METAL LATH OR OTHER
EXT. FINISH PER ELEVATIONS
T.O.P.
EXTERIOR CEMENT PLASTER
OVER PAPER BACKED METAL LATH.
LAP BLDG. PAPER O/ PLASTER
SCREED
PARAPET FRAMING PER
STRUCTURAL
SLOPE
CONTINUE ROOFING TO TERMINATE
UNDER PARAPET COPING
5/8" TYPE "X" GYSPSUM SHEATHING
FASTENER PER MFGR.
NOTE:
WHERE PARAPET HEIGHT EXCEEDS
MFGR'S. SPECIFICATIONS,
TRANSITION TO EXT. CEMENT
PLASTER W/ VERT. CONTROL JOINTS
@ 12'-0" O.C.
HOT AIR WELED
2% SLOPE
6 1/8"
24 GA. G.I. COPING. LAP JOINTS 6" AND SEAL
SPLICE PER WP DOCS. PAINT TO MATCH
ADJACENT FINISH
40 MIL HIGH TEMP SELF-ADHERED
MEMBRANE
3 COAT EXT. CEMENT PLASTER & LATH O/
WRB
BUILT-UP ROOFING
EMBED FASTENER IN SEALANT BED ABOVE
AND BENEATH COPING
NOTE:
WHERE PARAPET HEIGHT EXCEEDS MFGR'S.
SPECIFICATIONS, TRANSITION TO EXT.
CEMENT PLASTER W/ VERT. CONTROL
JOINTS @ 12'-0" O.C.
0' - 2"
2-PIECE "SPRING-LOK" TYPE
PLASTER REGLET
3-COAT EXT. CEMENT PLASTER AND
LATH O/ 2 LAYERS TYPE "D" BLDG.
PAPER - LAP PAPER O/ SCREED
DRIP SCREED
PLYWOOD SHEATHING PER
STRUCTURAL
WALL FRAMING & SUBSTRATE PER
PLANS. (WOOD SHEATHING SHOWN) 0' - 8" MIN.
NOTE: WHERE PARAPET HEIGHT
EXCEEDS MFGR'S. SPECIFICATIONS,
TRANSITION TO EXT. CEMENT
PLASTER W/ VERT. CONTROL
JOINTS @ 12'-0" O.C.
BUILT-UP ROOFING
CONDENSER UNIT PER
MECHANICAL DWGS
ROOFING ASSEMBLY PER WP
DRAWINGS. SEAL PENETRATIONS
TRIPLE TWO-BY BLOCKING BENEATH
MOUNTING SLEEPERS, RIP TO
SLOPE,TYP.
22 GA. GALV METAL FLASHING CAP
EQUIPMENT MOUNTING FRAME
& ISOLATORS PER MECH.
1/2" EXT. GRADE PLYWOOD
DIRECTLY BENEATH MECH. PAD
1/2" PLYWOOD
2" SQ. GALV. UNI-STRUT MOUNTING
RAIL
2"
2X4 FRAMING
12' MIN.
4" MIN.
8" MIN.
DAVIT, INSTALLED BY OTHERS
COMPATIBLE SEALANT WITH BOND
BREAKER IN "V" CONTINUOUS
ALONG PERIMETER, SLOPE FILLET
TO DRAIN
SINGLE PLY SKIRT, FULLY WELDED;
FULLY EMBEDDED IN SEALANT;
FASTEN WITH STAINLESS STEEL
HOSE CLAMP AND STAINLESS
STEEL FASTENER
TAPERED EDGE STRIP
SINGLE PLY
ROOFING SYSTEM
SHEATHING AND
FRAMING PER PLAN
STAINLESS STEEL
CLAMP AND
FASTENER
SEALANT TAPE
FASTEN PER
MANUFACTURER
PRE- MANUFACTURED
FLASHING BOOT
CONTINUOUS
HEAT WELD
SEAL PER
MANUFACTURER
ADJUSTABLE
PEDESTAL
TOP OF FINISH
FLOOR AT UNITS
UNIT
ROOF TOP
TERRACE
ROOF DECK PAVERS - SIZE AND TYPE PER
LANDSCAPE DRAWINGS
SLOPE
TO DRAIN
WATERPROOFING PER
BUILDING ENVELOPE
DRAWINGS
ROOF DRAIN
A
S
S
E
M
BLY
1H
R
R
A
T
E
D
R
O
O
F
ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1 ST PLAN CHECK SUBMITTAL 25% CD SET 05/31/2022
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt ROOF
DETAILS,
DRAINS,
SCUPPERS
3/4" = 1'-0" 1 A7.91
ROOF DRAIN
3" = 1'-0" 4
VENT AT ROOF
1" = 1'-0" 5
MULTIPLE PIPE PENETRATIONS
1 1/2" = 1'-0" 7
PARAPET W/COPING
3" = 1'-0" 8
PARAPET / WALL BASE
3" = 1'-0" 10
PARAPET COPING, TYP.
3" = 1'-0" 11
ROOFING TERMINATION @
PLASTER1
1 1/2" = 1'-0" 17
MECHANICAL EQUIPMENT PLATFORM
3" = 1'-0" 18 FALL PROTECTION ANCHOR1 1/2" = 1'-0" 19
DRAIN AT ROOF PAVERS
Date Issues / Revisions:
City Council 22 – 131 12/6/2022
1. WATERPROOFING SHOWN IS FOR REFERENCE ONLY
2. PROVIDE DOOR FLASHING AND WATERPROOFING PER W.P. DOCUMENTS.
3. PROVIDE PODIUM WATERPROOFING PER W.P. DOCUMENTS.
4. PROVIDED BELOW GRADE WATERPROOFING PER W.P. DOCUMENTS.
5. PROVIDE WATERPROOFING PRODUCTS AS SPECIFIED PER WATERPROOFING DOCUMENTS.
6. DOOR SILL SHALL HAVE A 1% SLIOPE TO THE EXTERIOR, TYPICAL.
MARBLE THRESHOLD REFER
TO HARDWARE SCHEDULE
A
REDUCER STRIP
CERAMIC TILE
FLOORING PER FINISH SCHED.
CERAMIC TILE AS OCCURS
VINYL
CARPET
CARPET
ALUMINUM THRESHOLD REFER
TO HARDWARE SCHEDULE
ALUMINUM THRESHOLD REFER
TO HARDWARE SCHEDULE
SET IN MASTIC AT EXT.
1/4" MAX. VERTICAL, TYP.
MAX. BEVEL 2:1, TYP.
1/2" M
AX. 1/2" M
AX
B .
C
D
E
VINYL
F
VINYL
G
3/4" ALUMINUM ANGLE SET IN
SILICONE SEALANT, PREDRILL
HOLES AT 8" O.C., FILL WITH
SEALANT AND ATTACH WITH
NO.8 X2" STAINLESS STEEL
SCREWS
CARPET
SHAPED WD BLOCKING
1/4' M
A
X 1/4' M
A
X
2 1
2 1
1/2" M
AX
2 1
PER MANUF. PER MANUF.
P
E
R
M
A
N
U
F.
GUIDE RAIL BY
MANUFACTURER MOUNTED
TO FACE OF WALL
3 HR RATED COILING
DOOR
NOTE:
VERIFY DIMENSIONS WITH MANUFACTURER
SEE FOR HEAD DETAIL
R.O. PER PLAN
EQ 2" EQ
PER. MFGR
LINE OF WALL
WHERE
OCCURS
POURED-IN-PLACE
CONCRETE WALL
SEALANT AND FOAM
BACKER ROD, TYP.
T-STRAP WALL ANCHOR
WELDED TO FRAME @ 24"
MAX. O.C. AND 8" MAX. FROM
TOP & BOTTOM. PROVIDE 4
PER JAMB MIN.
SOLID GROUT FRAME IN PLACE.
1 3/4"
CONCRETE OPENINGDOOR OPENING
SEE PLANS
CONCRETE WALL TO
HAVE 3/4" CHAMPHER
ON ALL EDGES, TYP.
HOLLOW METAL FRAME,
SEE DOOR SCHEDULE.
2 COAT EXTERIOR
CEMENT PLASTER
WHERE OCCURS @
EXTERIOR
G.I. DRIP FLASHING AT
HEAD, "J" MOLD AT JAMB
C.M.U. WALL
SEALANT AND BACKER
ROD
GYPSUM BOARD AT
FURRED WALL CONDITION
WITH SEALENT AND FOAM
BACKER AT FRAME
1 3/4"
1/4"
PER MFTR
1/4" EQ 2" EQ
MASONRY
OPENING
DOOR
OPENING
SEE PLANS
INSULATION PER SCHEDULE
AT EXTERIOR WALLS
EXTERIOR CEMENT PLASTER SYSTEM
OVER WEATHER-RESISTIVE BARRIER
WHERE OCCURS PER PLANS
PERPENDICULAR WALL AT JAMB WITH
(2) LAYER 5/8" EXTERIOR GYPSUM
SHEATHING. SEE PLAN FOR LOCATIONS
SELF ADHERING FLASHING WHERE SHOWN
TRIM WHERE SHOWN PER ELEVATIONS
METAL HEAD FLASHING - PAINT TO MATCH
FRAME. PROVIDE CONT. 1/2" CONT. SEALANT &
BACKER ROD @ EXT. JAMB CONDITION.
HOLLOW METAL DOOR AND FRAME,
PAINT PER SPECIFICATIONS,
FIRE RATING PER SCHEDULE
ALTERNATE DOOR LOCATION - SEE PLAN
NOTES:
SEE AX.XX FOR DISABLED ACCESS DOOR
CLEARANCE REQUIREMENTS.
SEE WP DOCUMNETS FOR ADDITIONAL WP
REQUIREMENTS.
SEALANT - TYPICAL
(2) LAYER 5/8" TYPE "X" GYP. BD.
EXTERIOR GYPSUM SHEATHING
AT PLASTER
S
E
E
PLA
N
BOTTOM BAR AND SAFETY
EDGE BY MANUFACTURER
M
A
N
U
F.
P
E
R
P
E
R
M
A
N
U
F.
PER MANUF. WALL PER PLAN
MOTOR AND EQUIPMENT
BY MANUFACTURER - FACE
MOUNTED TO WALL
HOOD
NOTE:
VERIFY DIMENSIONS WITH MANUFACTURER SEE
FOR JAMB DETAIL
R.O. PER SECTION
1 3/4" A
T JA
M
B
S
3" MIN.
1/2" 1/2"
2"
1 15/16"
(MIN.) VARIES
2" 1 15/16"
VARIES
PERPENDICULAR WALL WHERE
OCCURS AT JAMB CONDITIONS
EXTERIOR CEMENT PLASTER
AS OCCURS PER PLANS
5/8" TYPE "X" GYPSUM BOARD
EACH SIDE OF METAL STUDS
2 - LAYERS GYP BD EACH SIDE
AT 2-HOUR FIRE RATED WALL
DOOR - SEE SCHEDULE
INSULATION WHERE OCCURS
(2) 3 5/8" STRUCTURAL STUDS
AT JAMB/HEAD
LINE OF WALL WHERE STUD
SIZE IS GREATER THAN 3 5/8"
OR DBL STUDS - VERIFY
LOCATIONS OF OFFSET WITH
PLANS
HOLLOW METAL FRAME WITH
MINIMUM 3 ANCHORS PER
JAMB, 2 ANCHORS PER HEAD
WALL TYPE PER PLAN
1/4"
2 COAT CEMENT
PLASTER
ALUMINUM PLASTER 'J' MOLD
CAULKING
1 3/4" X 4 1/2" ALUMINUM
STOREFRONT SYSTEM
ALUMUNUM DOOR
JAMB PER SCHED.
SHIM AS REQUIRED
9 1/8" F.O.M.
F.O. FINISH
F.O. FRAME
2 1/2" 20 GAUGE METAL STUDS
DRYWALL
"L"
METAL
CAULKING WITH
FOAM BACKER ROD
INSULATION PER SCHEDULE
AT EXTERIOR WALLS
EXTERIOR CEMENT PLASTER SYSTEM
OVER WEATHER-RESISTIVE BARRIER
5/8" TYPE "X" GYPSUM BOARD
USG 5/8" TYPE "X" HUMITEK GYPSUM BOARD
W/DRYWALL "SETTING COMPUND" WHERE
OCCURS. REFER TO CORRIDOR PLANS.
SELF ADHERING FLASHING
TRIM WHERE SHOWN PER ELEVATIONS
METAL HEAD FLASHING - PAINT TO MATCH
FRAME. PROVIDE 1/2" CONT. SEALANT &
BACKER ROD @ EXT. JAMB CONDITION
HOLLOW METAL DOOR AND FRAME - PAINT
PER SPECS. SEE BLDG. PLAN FOR FIRE
RATING
ALTERNATE DOOR LOCATION - SEE PLAN
NOTES:
SEE A-40.1 FOR DISABLED ACCESS DOOR CLEARANCE
REQUIREMENTS. SEE WP DOCUMNETS FOR
ADDITIONAL WP REQUIREMENTS.
CASING EACH SIDE
WOOD FRAME AT HEAD AND
JAMBS
BI-PASS DOOR PER SCHED.
WITH PAINTED ALUM. TRACK AT
HEAD
SHIM SPACE
WALL TYPE VARIES
PER PLAN
NOTES:
SEE A-40.1 FOR DISABLED
ACCESS DOOR CLEARANCE
REQUIREMENTS.
ROUGH OPENING
HEIGHT
SEE PLAN
LINE OF WOOD
CASING BEYOND NANA WALL SL 60 DOOR
SYSTEM
SLOPE
CONCRETE PAVERS
PODIUM WP PER WP
DOCS.
F.F.
0' - 6"
HEAD FLASHING
0' - 1"
0' - 2 1/4"
0' - 0 1/4"
0' - 0 1/4"
NANA WALL SL 60 DOOR SYSTEM
HEAD FLASHING
SHAPED FILLER
3-COAT EXT PLASTER
O/ WRB PER WP DOCS
CEILING
WHERE
OCCUR
S
0' - 3 1/2" 0' - 0 3/4"
0' - 1"
1x STAIN
GRADE
WOOD
CASING
PLASTER SCREED O/ SELF- AHDERED WP MEMBRANE
1/2" EXT GYP.
SHEATHING
BEAM PER
STRUCTURAL
WOOD FRAMING PER PLANS
CL
1x STAIN
GRADE WOOD
CASING
EXT. CEMENT PLASTER
SYSTEM O/ SHEATHING
PER STRUC.
NANA WALL SL 60 DOOR
SYSTEM
0' - 0 3/4" 0' - 4"
0' - 0 3/4"
STEEL
PLASTER SCREED O/ SELF- ADHERED WP MEMBRANE
0' - 8"
NOTE: SEE WRITTEN SPECIFICATIONS FOR
SPECIFIC INSTALLATION PROCEDURES
DOOR CASING BEYOND
DOOR PER PLANS - PRIME TOP AND
BOTTOM RAILS
FRAME BEYOND, CUT SLOT FOR PLAN
AND CAULK
ALUMINUM DOOR DRIP WITH
WEATHERSTRIP
ALUMINUM DOOR THRESHOLD
FASTENED WITH SCREWS AND SET IN
TWO CONTINUOUS BEDS OF URETHANE
SEALANT
CEMENTITIOUS DECK COATING
2% SLOPE
1/4" M
AX
SILL PAN; SET IN FULL BED OF SEALANT
UNDER THRESHOLD
1/2" A
T
C
O
M
M
O
N
3/4" M
A
X
A
T
U
NIT
S
2 1
SILL PAN; SET IN FULL BED OF SEALANT
UNDER THRESHOLD
SELF-ADHERED MEMBRANE 2
1 ALL DRAWINGS AND WRITTEN MATERIAL APPEARING HEREIN CONSTITUTE THE ORIGINAL AND UNPUBLISHED WORK OF THE ARCHITECT AND THE SAME MAY NOT BE DUPLICATED, USED OR DISCLOSED WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT.
Job No.:
Drawn:
Checked:
BID Date:TAG design works
411 EAST HUNTINGTON DRIVESUITE 308
ARCADIA, CALIFORNIA 91006
PHN: (626) 446-5300
SHEET #
SHEET TITLE: 200 N. CABRILLO, SANTA ANA, CA 92701 ARCHITECT: PROJECT ADDRESS: THE MADISON 3/28/2022 DD SET
4/22/2022 100% DD
1 ST PLAN CHECK SUBMITTAL 25% CD SET 05/31/2022
Autodesk Docs://Santa Ana Madison Apartment/220101-Madison_Arch.rvt DOOR
DETAILS
12" = 1'-0" 1 A8.11
NOTES - DOOR FLASHING
3" = 1'-0" 2
INTERIOR THRESHOLD
3" = 1'-0" 4
COILING DOOR JAMB
3" = 1'-0" 5
DOOR FRAME, HEAD/JAMB,H.M. @ CONC
3" = 1'-0" 6
DOOR FRAME. HEAD/JAMB, H.M. @ CMU
3" = 1'-0" 7
HOLLOW-METAL DR HEAD@STAIR(2-HR)
1 1/2" = 1'-0" 8
COILING DOOR HEAD
3" = 1'-0" 9
DOOR FRAME,HEAD/JAMB,H.M.@MTL FRMG
3" = 1'-0" 10
DOOR FRAME, JAMB, STOREFRONT @ CMU
3" = 1'-0" 11
HOLLOW-METAL DOOR HEAD (JAMB SIM)
3" = 1'-0" 12
BIPASS DOOR HEAD
3" = 1'-0" 13 FOLDING DOOR THRESHOLD
3" = 1'-0" 14 FOLDING DOOR - HEAD
3" = 1'-0" 15 FOLDING DOOR JAMB - OPENING SIDE
6" = 1'-0" 16 PATIO FRENCH DOOR SILL
6" = 1'-0" 17 PATIO FRENCH DR SILL @ PODIUM LEVEL
Date Issues / Revisions:
City Council 22 – 132 12/6/2022
Planning and Building Agency
santa-ana.org/planning-and-building
Item # 23
City of Santa Ana
20 Civic Center Plaza, Santa Ana, CA 92701
Staff Report
December 6, 2022
TOPIC: First One-Year Extension for Site Plan Review No. 2020-03 and Variance No. 2020-06 for the 4th and Mortimer Mixed-Use Development Project Entitled at 409 and 509 East Fourth Street
AGENDA TITLE:
First One-year Extension of Site Plan Review No. 2020-03 and Variance No. 2020-06 for the 4th and Mortimer Mixed-Use Development Project Located at 409 and 509 East Fourth Street
RECOMMENDED ACTION
Adopt a resolution approving a one-year extension of Site Plan Review No. 2020-03 and Variance No. 2020-06 to December 15, 2023.
DISCUSSION
On October 12, 2020, the Planning Commission unanimously approved Site Plan Review No. 2020-03, for a development project over four stories in height, and Variance No. 2020-06, to allow an increase in the allowable building size and massing, to facilitate the construction of a new mixed-use residential and commercial development project located at 409 and 509 East Fourth Street. On October 22, 2020, an appeal (Appeal No. 2020-02) to the project was filed by Michael Lozeau with Lozeau Drury, LLP, on behalf of the Supporters Alliance for Environmental Responsibility (SAFER). On December 1, 2020, the City Council denied Appeal No. 2020-02, upholding the determination of the Planning Commission to approve the subject entitlements.
Pursuant to Section 41-647 of the Santa Ana Municipal Code (SAMC), entitlements such as variances automatically become void should the property owner fail to institute an action to comply with the provisions of the entitlements within two years of its approval. This section also allows the property owner to request an extension of the entitlement up to a period of three years from the date of the expiration.
The subject entitlements were in effect until December 31, 2021; however, due to difficulties stemming from the COVID-19 global pandemic, which affected the development industry worldwide, the applicant experienced delays in moving the project forward and constructing the new mixed-use development. During this time, a state of local emergency stemming from the COVID-19 pandemic was declared, which provided City Council 23 – 1 12/6/2022
Extension for Site Plan Review 2020-03 and Variance No. 2020-06 December 6, 2022
relief to residential developers by extending approvals of residential entitlements to December 31, 2022.
The applicant submitted construction drawings for plan check on August 1, 2022. The applicant submitted a subsequent submittal on September 19, 2022. Permits have not yet been issued; as a result, the applicant is requesting a one-year extension of the variances to ensure the entitlements remain valid by the time permits are ready for issuance. Since the applicant is currently working with staff to complete the plan check process, the Planning Division recommends that the entitlements for the development be extended for a period of one year to December 15, 2023.
ENVIRONMENTAL IMPACT
In accordance with the California Environmental Quality Act, the approval of the time extension is exempt form CEQA per Section 15061 (b)(3). This determination has been made as it has been determined that the proposed action to extend the existing, approved entitlement does not have the potential to cause a significant effect on the environment, as the existing, approved entitlement has already been evaluated pursuant to CEQA.
FISCAL IMPACT
There is no fiscal impact associated with this action.
EXHIBIT(S)
1. Resolution Extending SPR No. 2020-03 and VAR No. 2020-06 for One Year
2. Resolution No. 2020-093
3. Full project plans
Submitted By: Minh Thai, Executive Director of the planning and Building Agency Approved By: Kristine Ridge, City Manager
City Council 23 – 2 12/6/2022
Resolution No. 2022-XXX
RESOLUTION NO. 2022-XXX
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF
SANTA ANA APPROVING A ONE-YEAR EXTENSION OF
SITE PLAN REVIEW 2020-03 AND VARIANCE NO. 2020-
06 FOR THE 4
TH AND MORTIMER MIXED-USE
DEVELOPMENT TO BE LOCATED AT 409 AND 509 EAST
FOURTH STREET
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF SANTA ANA AS FOLLOWS:
Section 1. The City Council of the City of Santa Ana hereby finds, determines and declares as follows:
A. On October 12, 2020, the Planning Commission unanimously approved Site Plan Review No. 2020-03, for a development project over four stories in height, and Variance No. 2020-06, to allow an increase in the allowable building size and massing, for a new mixed-use development located at 409 and 509 East Fourth Street.
B. On October 22, 2020, an appeal (Appeal No. 2020-02) to the project was filed by Michael Lozeau with Lozeau Drury, LLP, on behalf of the Supporters Alliance for Environmental Responsibility (SAFER).
C. On December 1, 2020, the City Council denied Appeal No. 2020-02, upholding the determination of the Planning Commission to approve the subject entitlements.
D. Pursuant to Section 41-647 of the Santa Ana Municipal Code (SAMC), entitlements automatically become void should the property owner fail to institute an action to comply with the provisions of the entitlements within two years of its approval.
E. As a result of the global Covid-19 pandemic, the California Legislature approved AB 1561, which extended entitlements that were effective prior to March 4, 2020, and that were set to expire before December 31, 2021.
Due to the various dates of approval and expiration on December 15, 2020 and December 15, 2022, respectively, AB 1561 does not apply to the subject entitlement. Therefore, the applicant is requesting an extension by the City Council pursuant to Section 41-647 of the SAMC.
F. Due to difficulties stemming from the COVID-19 global pandemic, which affected the development industry worldwide, the applicant has experienced a number of uncertainties during the last two years that impact viability. These include construction and material cost increases, City Council 23 – 3 12/6/2022
Resolution No. 2022-XXX
uncertainty in labor availability, supply chain disruptions, and financial challenges arising out of an inflationary/high interest rate environment. All of these challenges have created delays in moving the project forward and constructing the new mixed-use development.
G. The applicant intends to complete the plan check process and obtain all necessary building permits for the project. The construction plans for the project have been submitted for plan check as of August 1, 2022. The applicant submitted a subsequent plan check submittal on September 19, 2022. The applicant expects to obtain permits and start construction in early 2023.
H. Pursuant to City of Santa Ana Municipal Code Section 41-647, where construction does not commence, these types of entitlements expire after two (2) years unless the applicant applies for, and the City Council approves, an extension. Up to three extensions may be granted.
I. It is the Planning Division’s policy to recommend no more than one-year extensions at a time, mainly in an effort to encourage the construction of previously approved projects.
J. The applicant filed a request for the extension on October 24, 2022. The extension request came before the City Council on December 6, 2022.
K. In accordance with the California Environmental Quality Act (CEQA) and the CEQA Guidelines, the extension for this project is exempt pursuant to Section 15061(b)(3). This determination has been made as it has been determined that the proposed action to extend the existing, approved entitlement does not have the potential to cause a significant effect on the environment, as the existing, approved entitlement has already been evaluated pursuant to CEQA.
Section 2. Site Plan Review No. 2020-03 and Variance No. 2020-06 are each hereby extended for a period of one (1) year until December 15, 2023. This decision is based upon the evidence submitted, which includes, but is not limited to, the Request for Council Action dated December 6, 2022, and exhibits attached thereto, and any public testimony, all of which are incorporated herein by this reference.
Section 3. This Resolution shall take effect immediately upon its adoption by the City Council, and the Clerk of the Council shall attest to and certify the vote adopting this Resolution.
ADOPTED this ___ day of _____________, 2022.
City Council 23 – 4 12/6/2022
Resolution No. 2022-XXX
_______________________
Vicente Sarmiento
Mayor
APPROVED AS TO FORM:
Sonia R. Carvalho
City Attorney
By:________________________
John M. Funk
Chief Assistant City Attorney
AYES: Councilmembers ___________________________________ NOES: Councilmembers ___________________________________ ABSTAIN: Councilmembers ___________________________________ NOT PRESENT: Councilmembers ___________________________________
CERTIFICATE OF ATTESTATION AND ORIGINALITY
I, Clerk of the Council, do hereby attest to and certify the attached Resolution No. 2022- ______ to be the original resolution adopted by the City Council of the City of Santa Ana on _______________, 2022.
Date: ____________ ________________________________
Clerk of the Council
City of Santa Ana
City Council 23 – 5 12/6/2022
LS 12. 1. 20
RESOLUTION NO. 2020-093
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF
SANTA ANA DENYING APPEAL APPLICATION NO. 2020-
02 AND UPHOLDING THE DETERMINATION OF THE
PLANNING COMMISSION TO APPROVE AN ADDENDUM
TO THE ENVIRONMENTAL IMPACT REPORT FOR THE
TRANSIT ZONING CODE PROJECT ( SCH NO.
2006071100) AND ADOPTION OF A MITIGATION
MONITORING AND REPORTING PROGRAM FOR SITE
PLAN REVIEW NO. 2020-03 AND VARIANCE NO. 2020-06
FOR A NEW MIXED -USE RESIDENTIAL AND
COMMERCIAL DEVELOPMENT FOR THE PROPERTIES
LOCATED AT 409 EAST FOURTH STREET ( SITE A) AND
509 EAST FOURTH STREET (SITE B)
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF SANTA ANA AS FOLLOWS:
Section 1. The City Council of the City of Santa Ana hereby finds, determines and declares as follows:
A. On October 12, 2020, the Planning Commission of the City of Santa Ana held a duly noticed public hearing to consider various entitlements including Site Plan Review No. 2020-03, Variance No. 2020- 06, and Amendment Application 2020-04 to allow the construction of a new mixed -use residential and commercial development consisting of 169 residential rental units and 11, 361 square feet of commercial space at 409 and 509 East Fourth Street.
After receiving public testimony on the item, the Planning Commission voted unanimously ( 7:0) to adopt a resolution approving an Addendum to the Environmental Impact Report ( EIR) for the Transit Zoning Code Project, mitigation monitoring and reporting program, Site Plan Review No. 2020-03 as conditioned, and Variance No. 2020-06 as conditioned. In addition, the Planning Commission recommended that the City Council adopt a resolution approving an Addendum to the Environmental Impact Report for the Transit Zoning Code Project, mitigation monitoring and reporting program, and an ordinance approving Amendment Application No. 2020- 04 for Specific Development No. 84 (SD84).
B. On October 22, 2020, Michael Lozeau with Lozeau Drury, LLP, on behalf of the Supporters Alliance for Environmental Responsibility (SAFER) hereinafter referred to as " Appellant", submitted an appeal application pursuant to Section 41- 645 of the Santa Ana Municipal Code ( SAMC) requesting that the City Council reconsider the Planning Commission' s decision based on the following reasons:
Resolution No. 2020-093
I. California Environmental Quality Act ( CEQA) compliance.
Specifically, the Appellant states that the "City failed to comply with the CEQA by failing to prepare a project -specific EIR for the project';
II. The Appellant states that, " The City failed to comply with the Housing Opportunity Ordinance ( HOO) by failing to require the developer to include affordable housing units in the project; and III. The Appellant states that, `The Planning Commission abused its discretion by failing to read or consider comments submitted by SAFER."
C. Pursuant to SAMC Section 41- 645 ( a), appeals can only be made on a decision or requirement made by the Planning Commission. Of the above - mentioned appeal reasons, the only action taken by the Planning Commission was the action to adopt a resolution approving the addendum to the EIR for the TZC. The subsequent appeal items do not satisfy the requirements of SAMC Section 41- 645 ( a) and should not be considered as part of the appeal:
I. No decision or action was taken by the Planning Commission regarding the HOO requirements because the HOO did not apply to the project; and
II. Consideration of a public comment letter received does not constitute " a decision or requirement made by the Planning Commission".
Nonetheless, a comprehensive response and findings are provided below on all appeal items received.
D. On December 1, 2020, the City Council conducted a duly noticed public hearing on Appeal Application No. 2020-02 and found that:
The City complied with the California Environmental Quality Act (CEQA) requirements by preparing an addendum to the previously certified 2010 Transit Zoning Code Environmental Impact report ( EIR). CEQA does permit the use of an addendum when the original EIR being relied upon was a Program EIR. Public Resources Code Section 21166 and State CEQA Guidelines Section 15162 clearly establish when an agency must prepare a Supplemental or Subsequent EIR, and when an agency is permitted instead to prepare an Addendum. If an agency determines that one of the conditions described in Public Resources Code section 21166 or State CEQA Guidelines section 15162 is present, the agency must prepare either a Subsequent EIR or a Supplemental EIR. When none of those conditions are present, but it is necessary to make changes to a previous EIR, the agency may prepare an addendum. This process applies regardless of whether the original EIR is a Program or Resolution No. 2020-093
City Council 23 – 7 12/6/2022
Project EIR. Nothing in State CEQA Guidelines section 15152 describing the process for utilizing a Supplemental or Subsequent EIR or negative declaration) prohibits use of an addendum where none of the conditions of Public Resources Code section 21166 or State CEQA Guidelines section 15162 are present. Nothing in State CEQA Guidelines sections 15162 or 15164 prohibit use of an addendum where the original EIR is a Program, and not a Project, EIR.
As established in these sections of the Public Resources Code and the State CEQA Guidelines, one of the circumstances described in Public Resources Code section 21166 or State CEQA Guidelines section 15162 must be present before either a Subsequent or Supplemental EIR is required. Here, none of those conditions are present. These conditions are:
Substantial changes are proposed which will require major revisions of the previous EIR due to the involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects; ii, Substantial changes occur with respect to the circumstances under which the project is undertaken which will require major revisions of the previous EIR due to the involvement of new significant effects or a substantial increase in the severity of previously identified significant effects; or
iii. New information has come to light showing new impacts, substantially more severe impacts, that mitigation measures or alternatives previously found to be infeasible would actually be feasible, or that mitigation measures or alternatives previously not identified would reduce impacts.
This is also consistent with CEQA Guidelines section 15152(f), which the Appellant incorrectly claims prohibits use of addenda when the original EIR is a Program EIR. Section 15152(f) states, " A later EIR shall be required when the initial study or other analysis finds that the later project may cause significant effects on the environment that were not adequately addressed in the prior EIR." For the subject project, the other analysis" ( including technical studies and the text of the Addendum) found that no additional significant effects would occur beyond those already addressed in the 2010 EIR. An addendum is therefore the appropriate CEQA document.
That the City has complied with the Housing Opportunity Ordinance HOO) requirements. The HOO does not apply to the project because the project does not exceed the residential density permitted in the General Plan. As recently amended, the HOO only applies when a project requires a General Plan Amendment.
Resolution No. 2020-093
City Council 23 – 8 12/6/2022
The Appellant' s comment letter cites to an outdated and superseded version of Section 41- 1902(b)( 1). The HOO was amended on September 1, 2020, and the comment letter does not reflect the amended language. While previously, Section 41- 1902( b)( 1) applied the HOO to any project that exceeded the maximum density permitted by zoning, the recent amendments remove this reference. As amended, the HOO now only applies when a residential project proposes a residential density above the General Plan permitted density. The 4th and Mortimer Mixed -Use Development project is consistent with the General Plan. No General Plan Amendment is required for the Project.
The Project seeks only a zone change, on only a portion of the project site. No density allowance above that currently permitted by the site' s General Plan designation is proposed. Therefore, the HOO does not apply.
III. The Planning Commission did not abuse its discretion and did consider comments submitted by Lozeau Drury, LLP, on behalf of SAFER. The Planning Commission considered Mr. Drury' s public comment and received input from the City Attorney and the City's environmental consultant regarding the whether the addendum prepared for the project was the appropriate document. Both the City Attorney and the consultant were confident that no subsequent CEQA analysis was required for the project other than the addendum which was prepared.
Again, this was based on the fact that the technical studies evidenced that an EIR Addendum to the previously -certified 2010 EIR was the appropriate CEQA document to evaluate and disclose the project's impacts. Therefore, the Planning Commission did consider Mr. Drury's comments and concerns but agreed with staff's recommendation that the addendum was the appropriate environmental document.
Section 2. The City Council, after hearing, considering and weighing all evidence in the record presented on behalf of all parties and being fully informed of the application, the Planning Commission' s decision, and the appeal, hereby finds and determines that the Planning Commission' s decision was not made in error, that the Planning Commission' s decision was not an abuse of discretion by the Planning Commission and that the Planning Commission' s decision was supported by substantial evidence in the record.
Section 3. In accordance with the California Environmental Quality Act CEQA), the Planning Commission of the City of Santa Ana hereby finds, determines, and declares as follows:
Based on the substantial evidence set forth in the record, including but not limited to the Environmental Impact Report ( EIR) for the Transit Zoning Code Project SCH NO. 2006071100) and the 2020 4th and Mortimer Mixed -Use Development EIR Addendum, the City Council finds that an addendum is the appropriate document for Resolution No. 2020-093
City Council 23 – 9 12/6/2022
disclosing the changes to the subject properties, and that none of the conditions identified in Public Resources Code section 21166 and State CEQA Guidelines section 15162 requiring subsequent environmental review have occurred, because:
A. The project does not constitute a substantial change that would require major revisions of the 2010 EIR due to the involvement of new significant environmental effects or a substantial increase in the severity of previously identified significant effects.
B. There is not a substantial change with respect to the circumstances under which the project will be developed that would require major revisions of the 2010 EIR due to the involvement of new significant environmental effects or a substantial increase in the severity of the previously identified significant effects.
C. New information of substantial importance has not been presented that was not known and could not have been known with the exercise of reasonable diligence at the time the 2010 EIR was certified or adopted, showing any of the Following: ( i) that the modifications would have one or more significant effects not discussed in the earlier environmental documentation; ( ii) that significant effects previously examined would be substantially more severe than shown in the earlier environmental documentation; ( iii) that mitigation measures or alternatives previously found not to be feasible would in fact be feasible and would substantially reduce one or more significant effects, but the Applicant declined to adopt such measures; or ( iv) that mitigation measures or alternatives considerably different from those analyzed previously would substantially reduce one or more significant effects on the environment, but which the Applicant declined to adopt.
Further, the City Council finds that, pursuant to State CEQA Guidelines Section 15164, only minor changes or additions to the 2010 EIR are necessary to address the proposed project. In making this finding, the City Council has considered both the Addendum and the certified, final 2010 EIR.
Section 4. The Applicant shall indemnify, protect, defend and hold the City and/ or any of its officials, officers, employees, agents, departments, agencies, authorized volunteers, and instrumentalities thereof, harmless from any and all claims, demands, lawsuits, writs of mandamus, and other and proceedings ( whether legal, equitable, declaratory, administrative or adjudicatory in nature), and alternative dispute resolution procedures ( including, but not limited to arbitrations, mediations, and such other procedures), judgments, orders, and decisions ( collectively " Actions"), brought against the City and/or any of its officials, officers, employees, agents, departments, agencies, and instrumentalities thereof, that challenge, attack, or seek to modify, set aside, void, or annul, any action of, or any permit or approval issued by the City and/or any of its officials, officers, employees, agents, departments, agencies, and instrumentalities thereof ( including actions approved by the voters of the City) for or concerning the project, whether such Actions are brought under the Ralph M. Brown Resolution No. 2020-093
City Council 23 – 10 12/6/2022
Act, California Environmental Quality Act, the Planning and Zoning Law, the Subdivision Map Act, Code of Civil Procedure sections 1085 or 1094. 5, or any other federal, state or local constitution, statute, law, ordinance, charter, rule, regulation, or any decision of a court of competent jurisdiction. It is expressly agreed that the City shall have the right to approve, which approval will not be unreasonably withheld, the legal counsel providing the City's defense, and that Applicant shall reimburse the City for any costs and expenses directly and necessarily incurred by the City in the course of the defense.
City shall promptly notify the Applicant of any Action brought and City shall cooperate with Applicant in the defense of the Action.
Section 5. The City Council of the City of Santa Ana hereby denies Appeal Application No. 2020-02, thereby upholding the Planning Commission' s approval of an Addendum to the Environmental Impact Report ( EIR) for the Transit Zoning Code Project (SCH NO. 2006071100), mitigation monitoring and reporting program, Site Plan Review No. 2020-03 as conditioned, and Variance No. 2020-06 as conditioned. This decision is based upon the evidence submitted at the abovesaid hearing, which includes, but is not limited to: the Request for City Council Action dated December 1, 2020, and exhibits attached thereto, and the public testimony, written and oral, all of which are incorporated herein by this reference.
ADOPTED this 15t day of December, 2020.
APPROVED AS TO FORM:
Sonia R. Carvalho
City Attorney
By:.(,/ (• nl
Lisa Storck
Assistant City Attorney
Resolution No. 2020-093
City Council 23 – 11 12/6/2022
AYES: Councilmembers
NOES: Councilmembers
ABSTAIN: Councilmembers
Bacerra, Mendoza, Penaloza, Solorio,
Villegas (5)
None (0)
Pulido, Sarmiento ( 2)
NOT PRESENT: Councilmembers None (0)
CERTIFICATE OF ATTESTATION AND ORIGINALITY
I, DAISY GOMEZ, Clerk of the Council, do hereby attest to and certify the attached Resolution No. 2020- 093 to be the original resolution adopted by the City Council of the City of Santa Ana on December 1, 2020.
Date: 1?.
Daisy Gom z
Clerk of the Council
City of Santa Ana
Resolution No. 2020-093
City Council 23 – 12 12/6/2022
A0-01 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed.
Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL 4TH AND MORTIMER 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701 PERMIT NUMBER ABBREVIATIONS PROJECT TEAM DIRECTORY LEGAL DESCRIPTION VICINITY MAP DEFERRED SUBMITTALS FIRE SPRINKLER SYSTEM THE CONTRACTOR IS RESPONSIBLE FOR SUBMITTING THE FOLLOWING DEFERRED SUBMITTALS TO THE CITY OFFICIALS FOR REVIEW AND APPROVAL. FIRE ALARM SYSTEM SIGNAGE PROGRAM INCLUDING ALL SITE & BUILDING ACCESSIBILITY SIGNAGE ROOF / FLOOR TRUSS SYSTEM 5. 3. 1. 4. 2. 6. SWIMMING POOL & SPA SECURITY SYSTEM SHEET INDEX TEL. CIVIL ENGINEER Fuscoe Engineering, Inc. 16795 Von Karman, Suite #100 Irvine, CA 92606 (949) 474-1960 Josh Ruiz TEL. LANDSCAPE ARCHITECT LandStudio 360 333 El Camino Real, Studio #200 T ustin, CA 92780 (949) 382-5811 Alex Polen David Ling TEL. DEVELOPER Red Oak Investments 4199 Campus Drive Irvine, CA 92612 (714) 342-2502 Andrew Nelson Alex Wong TEL. ARCHITECT KTGY ARCHITECTURE + PLANNING 17911 Von Karman Ave., Ste. 200 Irvine, CA 92614 (949) 851-2133 Debbie Holland TEL. STRUCTURAL ENGINEER DCI Engineers 2600 Michelson Dr #930 Irvine, CA 92612 (949) 892-4956 Maggie Clavijo TEL. DRY UTILITY DRI Utility Consulting 25060 Hancock Ave, Ste 103 #464 Murrieta, CA 92562 951-757-9096 Dave Ramirez TEL. MECHANICAL ENGINEER Multi Mechancial, Inc 469 E. Blaine Street Corona, CA 92879 951-736-6040 Brandon Abblitt TEL. GREEN BUILDING VCA Green 1845 W. Orangewood Ave, Ste 220 Orange, CA 92868 714-363-4700 Roshni Lad TEL. PLUMBING ENGINEER AMPAM 17036 Avakon Blvd. Carson, CA 90746 310-835-1532 Daniel Lucas TEL. ELECTRICAL ENGINEER SBE Electrical Contracting 2817 McGaw Ave Irvine, CA 92614 714-544-5065 Eric Grossman TEL. FIRE PROTECTION Automatic Fire Protection 714-841-2066 Craig Spicer TEL. INTERIOR DESIGNER Ariel Fox Design 16 N Marengo Suite 415 Pasadena, CA 91101 (818) 465-3366 Ariel Johnson Hannah Askey TEL. LOW VOLTAGE SYSTEMS HCI Systems, Inc. 1731 Reynolds Ave Irvine, CA 92614 949-724-5000 Mike Peters TEL. GEOTECHNICAL Geocon West, Inc. 2807 McGaw Ave Irvine, CA 92614 949-346-1109 Jelisa Thomas Adams TEL. SIGNAGE TEL. ACOUSTICAL Eilar Associates, Inc. 210 South Juniper St, Ste 100 Escondido, CA 92025 760-738-5570 Mo Ouwenga GENERAL NOTES SHEET INDEX 7. METAL STAIRS 8. ELEVATORS 9. METAL AND GLASS GUARDRAILS 10. STOREFRONT SYSTEM 11. AWNINGS AND CANOPIES SHEET INDEX LOG OF ISSUED DOCUMENTS COPYRIGHT C A.B. ANCHOR BOLT ABV. ABOVE A/C CONDENSING UNIT ACOUST. ACOUSTICAL A.D. AREA DRAIN ADJ. ADJUSTABLE A.F.F. ABOVE FINISH FLOOR ALT. ALTERNATE ALUM. ALUMINUM APPROX. APPROXIMATE ARCH. ARCHITECT ASPH. ASPHALT BA. BATHROM BD. BOARD BITUM. BITUMINOUS BLDG. BUILDING BLK. BLOCK BLKG. BLOCKING BM. BEAM BR. BEDROOM B.U.R. BUILT-UP-ROOFING CAB. CABINET C.B. CATCH BASIN CEM. CEMENT CER. CERAMIC C.I. CAST IRON C.G. CORNER GUARD CJ CEILING JOIST CLG. CEILING JOIST CLKG. CAULKING CLO. CLOSET CLR. CLEAR / CLEARANCE CMU CONCRETE MASONRY UNIT COL. COLUMN CONC. CONCRETE CONSTR. CONSTRUCTION CONT. CONTINUOUS CORR. CORRIDOR CPT CARPET CSMT CASEMENT CNTR. COUNTER CTR. CENTER DBL. DOUBLE DEPT. DEPARTMENT D.F. DRINKING FOUNTAIN DET. DETAIL DH DOUBLE HUNG DIA. DIAMETER DIM. DIMENSION DISP. DISPENSER DN. DOWN DR. DOOR OPENING DS DOWNSPOUT DW DISHWASHER DWG'S DRAWINGS DWR. DRAWER E.J. EXPANSION JOINT EL. ELEVATION ELEC. ELECTRICAL ELEV. ELEVATOR EMER. EMERGANCY ENCL. ENCLOSED E.P. ELECTRICAL PANEL EQMT. EQUIPMENT EXH. EXHAUST EXT. EXTERIOR EXT'G EXISTING F.A. FIRE ALARM F.A.U. FORCED AIT UNIT F.D. FLOOR DRAIN FDN. FOUNDATION F.E. FIRE EXTINGUISHER F.E.C. FIRE EXTINGUISHER CABINET F.F. FINISH FLOOR F.G. FINISH GRADE FGL. FIBERGLASS FIN. FINISH F.J. FLOOR JOIST FLR. FLOOR F.O.C. FACE OF CONCRETE F.O.F. FACE OF FINISH F.O.S. FACE OF STUD/SHEATHING FR FRENCH FRM'G FRAMING FURR. FURRING GA. GUAGE GALV. GALVANIZED GAR. GARAGE G.B. GRAB BAR GFCI GROUND FAULT CIRCUIT INTERUPTER G.I. GALVANIZED IRON GL GLASS / GLAZING GLB GLUE LAMINATED BEAM GSM GALVANIZED SHEET METAL GYP. GYPSUM GYP.BD. GYPSUM BOARD H.B. HOSE BIBB HC HOLLOW CORE HDR. HEADER HDWD. HARDWOOD HM HOLLOW METAL HORIZ. HORIZONTAL HVAC HEATING VENTILATING AIR CONDITIONING INSUL. INSULATION INT. INTERIOR LAM. LAMINATE LAV. LAVATORY LT. LIGHT MBR MASTER BEDROOM MC MEDICINE CABINET MECH. MECHANICAL MEMB. MEMBRANE MET. METAL MFG MANUFATURING MFR. MANUFACTURER MIR. MIRROR MISC. MISCELLANEOUS MLD'G MOULDING MTD. MOUNTED MUL. MULLION NG. NATURAL GRADE N.I.C. NOT IN CONTRACT NO. NUMBER NOM. NOMINAL N.T.S. NOT TO SCALE OBS. OBSCURE O.C. ON CENTER OPNG. OPENING OPP. OPPOSITE OSA. OUTSIDE AIR PB PUSH BUTTON PDR. POWDER ROOM PL. PLATE PLYWD. PLYWOOD PLUMB. PLUMBING P.O.C. POINT OF CONNECTION PR. PAIR PREFAB. PREFABRICATED R.A.G. RETURN AIR GRILLE R.C. RESILIENT CHANNEL R.D. ROOF DRAIN REF. REFERENCE REFR. REFRIGERATOR REINF REINFORCED RGTR. REGISTER REQ. REQUIRED RESIL. RESILIENT RJ RAFTER JOISTS RM. ROOM R.O. ROUGH OPENING SC SOLID CORE SCHED. SCHEDULE SERV. SERVICES S.F SQUARE FEET SGD SLIDING GLASS DOOR SH SINGLE HUNG SHT. SHEET SHT'G SHEATHING SIM. SIMILAR SL SLIDING SPEC. SPECIFICATIONS SQ. SQUARE SSSP SINGLE SHELF SINGLE POLE SSDP SINGLE SHELF DOUBLE POLE STD. STANDARD STL. STEEL STOR. STORAGE STRUCT. STRUCTURAL SYM. SYMMETRICAL T.B. TOWEL BAR TEL. TELEPHONE TEMP. TEMPERED TER. TERRAZZO T&G TONGUE AND GROOVE TRSM. TRANSOM T.V. TELEVISION TYP. TYPICAL T.O.SHTG. TOP OF SHEATHING T.O.C. TOP OF CONCRETE OR CURB T.O.P. TOP OF PARAPET T.O.W. TOP OF WALL U.N.O. UNLESS NOTED OTHERWISE VCT. VINYL COMPOSITE TILE VEST. VESTIBULE W.C. WATER CLOSET WD. WOOD WDW. WINDOW W.H. WATER HEATER W.I. WROUGHT IRON W.I.C. WALK-IN CLOSET WSCT. WAINSCOT 1. THE CONTRACTOR SHALL REVIEW ALL CONSTRUCTION DOCUMENTS PRIOR TO BID AND START OF CONSTRUCTION. THE CONTRACTOR SHALL CONFIRM THAT WORK INDICATED IN THE CONSTRUCTION DOCUMENTS IS BUILDABLE AS SHOWN. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE OWNER AND ARCHITECT SHALL BE NOTIFIED IN WRITING IMMEDIATELY. 2. THE CONTRACTOR SHALL COMPARE ALL CONSTRUCTION DOCUMENTS WITH THE EXISTING SITE CONDITIONS PRIOR TO BID AND START OF CONSTRUCTION. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE OWNER AND ARCHITECT SHALL BE NOTIFIED IN WRITING IMMEDIATELY. 3. DO NOT SCALE DRAWINGS. REVIEW ALL DIMENSIONS SHOWN ON CONSTRUCTION DOCUMENTS PRIOR TO BID AND START OF CONSTRUCTION. IN THE EVENT A DISCREPANCY IS FOUND IN THE CONTRACT DOCUMENTS, THE OWNER AND ARCHITECT SHALL BE NOTIFIED IN WRITING IMMEDIATELY. 4. FIRE RESISTANCE RATINGS, ASSEMBLIES, CLASSIFICATIONS, STANDARDS AND LISTINGS INDICATED ARE TAKEN FROM VARIOUS REFERENCE STANDARDS. MAINTAIN, AT THE PROJECT SITE, A COPY OF AN APPLICABLE EDITION OF EACH REFERENCE STANDARD. 5. REVIEW PLAN LAYOUT, VERIFY AND COORDINATE INTERFACES OF ALL PORTIONS OF THE WORK PRIOR TO ACTUAL EXECUTION. 6. PROVIDE ALL WORK NECESSARY FOR A COMPLETE PROJECT, INCLUDING ANYTHING WITHIN THE LIMIT OF WORK, OUTSIDE PROPERTY LINE, ON ADJACENT PROPERTIES AND IN THE PUBLIC WAY. 7. ALL CONSTRUCTION SHALL COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES AND AMENDMENTS. 8. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR CONSTRUCTION MEANS AND METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES REQUIRED FOR SAFE EXECUTION OF THE WORK AND FOR INITIATING, MAINTAINING AND SUPERVISING ALL SAFETY PRECAUTIONS AND PROGRAMMING IN CONNECTION WITH THE WORK, CONTRACTOR SHALL HIRE SUB-CONTRACTORS AND SUPPLIERS WITH PROVEN ABILITY TO PROVIDE AND PERFORM QUALITY WORKMANSHIP ON THIS TYPE OF PROJECT. TITLE SHEET PARCEL 1 LOT 1 IN BLOCK 8 OF FRUIT'S ADDITION TO SANTA ANA, AS SHOWN ON A MAP RECORDED IN BOOK 9, PAGE 91 OF MISCELLANEOUS MAPS, RECORDS OF LOS ANGELES COUNTY, CALIFORNIA. PARCEL 2 THE WEST HALF OF LOT 2 IN BLOCK 8 OF FRUIT'S ADDITION TO SANTA ANA, AS SHOWN ON A MAP RECORDED IN BOOK 9, PAGE 91 OF MISCELLANEOUS MAPS, RECORDS OF LOS ANGELES COUNTY, CALIFORNIA. APN: 398-338-08 03-18-2022 50% DD PROGRESS SET 05-20-2022 100% DD PROGRESS SET 08-01-2022 FIRST PLAN CHECK SUBMITTAL ARCHITECTURAL Number Description A0-01 TITLE SHEET A0-02 SHEET INDEX A0-02 Code & Project Summaries A0-03A Building A Allowable Area Calculations A0-03B Building B Allowable Area Calculations A0-04 Building and Unit Summary A0-11 Building A First Floor Fire Protection Plans A0-12 Building A Second Floor Fire Protection Plans A0-13 Building A Third Floor Fire Protection Plans A0-14 Building A Fourth Floor Fire Protection Plans A0-15 Building A Fifth Floor Fire Protection Plans A0-16 Building A Sixth Floor Fire Protection Plans A0-17 Building A Seventh Floor Fire Protection Plans A0-21 Building B First Floor Fire Protection Plan A0-22 Building B Second Floor Fire Protection Plan A0-23 Building B Third Floor Fire Protection Plan A0-24 Building B Fourth Floor Fire Protection Plan A0-25 Building B Fifth Floor Fire Protection Plan A0-31 Building A First Floor Exiting Analysis A0-32 Building A Second Floor Exiting Analysis A0-33 Building A Third Floor Exiting Analysis A0-34 Building A Fourth Floor Exiting Analysis A0-35 Building A Fifth Floor Exiting Analysis A0-36 Building A Sixth Floor Exiting Analysis A0-37 Building A Seventh Floor Exiting Analysis A0-41 Building B First Floor Exiting Analysis A0-42 Building B Second Floor Exiting Analysis A0-43 Building B Third Floor Exiting Analysis A0-44 Building B Fourth Floor Exiting Analysis A0-45 Building B Fifth Floor Exiting Analysis A0-70 Conditions of Approval A0-71 Conditions of Approval A0-72 Conditions of Approval A0-73 Conditions of Approval A0-74 Conditions of Approval A0-75 Conditions of Approval A0-80 Geotechnical Report A0-81 Geotechnical Report A0-82 Geotechnical Report A0-83 Geotechnical Report A0-84 Geotechnical Report A0-85 Geotechnical Report A0-86 Geotechnical Report A0-87 Geotechnical Report A0-88 Geotechnical report A0-89 Geotechnical Report A0-90 Geotechnical Report A0-91 Exterior Acoustical Analysis Report A0-92 Exterior Acoustical Analysis Report A0-93 Exterior Acoustical Analysis Report A0-94 Exterior Acoustical Analysis Report A0-95 Addressing Plans & USPS Approval A0-96 Addressing Plans & USPS Approval A0-97 Addressing Plans & USPS Approval A0-98 Addressing Plans & USPS Approval A0-99 Addressing Plans & USPS Approval A0-100 Addressing Plans & USPS Approval A0-101 Addressing Plans & USPS Approval A0-102 Addressing Plans & USPS Approval A0-103 Addressing Plans & USPS Approval A0-104 Addressing Plans & USPS Approval A0-105 Addressing Plans & USPS Approval A0-106 Addressing Plans & USPS Approval A0-107 Addressing Plans & USPS Approval A0-108 Addressing Plans & USPS Approval A0-109 Addressing Plans & USPS Approval A1-20 Architectural Site Plan A1-21 Police Department Building Security Regulations A1-22 Police Department Building Security Regulations A1-23 Police Department Building Security Regulations A1-30 Fire Access Plan A1-30.1 Fire Flow Test Report A1-40 Calculated Grade Plane & Building Height A1-50 Exterior Opening Analysis Building A A1-51 Exterior Opening Analysis Building A A1-52 Exterior Opening Analysis Building B A1-53 Exterior Opening Analysis Building B A1-54 Exterior Opening Analysis Building A Garage A1-55 Exterior Opening Analysis Building A Garage A1-56 Exterior Opening Analysis Building B Garage A1-57 Exterior Opening Analysis Building B Garage A2-11S Building A First Level Slab Plan A2-11 Building A First Level Floor Plan A2-12S Building A Second Level Slab Plan A2-12 Building A Second Level Floor Plan A2-13S Building A Third Level Slab Plan A2-13 Building A Third Level Floor Plan A2-14 Building A Fourth Level Floor Plan A2-15 Building A Fifth Level Floor Plan A2-16 Building A Sixth Level Floor Plan A2-17 Building A Seventh Level Floor Plan A2-18 Building A Roof Plan A2-20 Building A North & East Exterior Elevations A2-21 Building A South & West Exterior Elevations A2-22 Building A Courtyard Elevations A2-30 Building A Sections A2-31 Building A Sections A2-40 Building A Wall Sections A2-41 Building A Wall Sections A2-42 Building A Wall Sections A2-43 Building A Wall Sections A2-51S Building B First Level Slab Plan A2-51 Building B First Level Floor Plan A2-52 Building B Second Level Floor Plan A2-53 Building B Third Level Floor Plan A2-54 Building B Fourth Level Floor Plan A2-55 Building B Fifth Level Floor Plan A2-56 Building B Roof Plan A2-60 Building B North & East Exterior Elevations A2-61 Building B South & West Exterior Elevations A2-62 Building B Courtyard Elevations A2-63 Building B Courtyard Elevations A2-70 Building B Sections A2-71 Building B Sections A2-80 Building B Wall Sections A2-81 Building B Wall Sections A5-01 Unit 0.1 Plans and Interior Elevations A5-02 Unit 0.2 Plans and Interior Elevations A5-03 Unit 0.3 Plans and Interior Elevations A5-11 Unit 1.1 Plans and Interior Elevations A5-12 Unit 1.1 Plan Variations A5-13 Unit 1.2 Plans and Interior Elevations A5-21 Unit 2.1 Plans and Interior Elevations A5-22 Unit 2.1 Plans and Variations A5-23 Unit 2.1 Plan Variations A5-24 Unit 2.1 Plan Variations A5-25 Unit 2.2 Plans and Interior Elevations A5-26 Unit 2.2 Plan Variations A5-27 Unit 2.2 Plan Variations A5-28 Unit 2.2 Plan Variations A5-29 Unit 2.2 Plan Variation A5-30 Unit 2.3 Plans and Interior Elevations A5-31 Unit 2.3 Plan Variations A5-32 Unit 2.4 Plans and Interior Elevations A5-33 Unit 2.4 Plan Variation A5-34 Unit 2.5 Plans, Variation and Interior Elevations A5-35 Unit 2.6 Plans and Interior Elevations A5-36 Unit 3.1 Plans and Interior Elevations A5-37 Unit 3.2 Plans and Interior Elevations A5-38 Unit 3.2 Plans and Variation A5-39 Unit 3.4 Plans A5-40 Unit 3.4 Plan and Interior Elevations A5-41 Unit 4.1 Plans and Interior Elevations A5-42 Unit 4.1 Plan and Variations A5-43 Unit 4.1 Plans and Variations A5-44 Unit 4.1 Plan Variations A5-45 Unit 4.2 Plans A5-46 Unit 4.2 Plan and Interior Elevations A5-50 Restaurant Enlarged Plan - Level 1 A5-51 Restaurant, Pool Equipment Enlarged Plan - Level 2 A5-52 Retail Enlarged Plan - Level 1 A5-53 Retail and Tenant Storage Enlarged Plan - Level 2 A5-54 Leasing & Amenity Enlarged Plan - Level 1 A5-55 Leasing & Amenity Enlarged Plan - Level 2 A5-56 Leasing & Amenity Enlarged Reflected Ceiling Plan A5-57 Leasing & Amenity Interior Elevations A5-60 Clubroom Enlarged Plan - Level 3 A5-61 Clubroom Enlarged Reflected Ceiling Plan A5-62 Clubroom Enlarged Plan - Primary Structural Frame A5-63 Roof Deck Enlarged Plan A5-64 Mailroom Enlarged Plan & Interior Elevations A5-70 Stair A1 Enlarged Plans A5-71 Stair A1 Section A5-72 Stair A2 Enlarged Plans A5-73 Stair A2 & A3 Section A5-74 Stair A3 Enlarged Plans A5-75 Stair A4 Enlarged Plans A5-76 Stair A4 Enlarged Plans A5-77 Stair A4 Section A5-78 Stair B1 Enlarged Plans A5-79 Stair B1 Section A5-80 Stair B2 Enlarged Plans A5-81 Stair B2 Section A5-82 Stair B3 Enlarged Plans A5-83 Stair B3 & B4 Section A5-84 Stair B4 Enlarged Plans A5-90 Elevators A1 & A2 Plans A5-91 Elevators A1 & A2 Sections A5-92 Elevators B1 & B2 Plans A5-93 Elevators B1 & B2 Sections A5-94 Building A Trash Room Plans A5-95 Building A Trash Chute Sections A5-96 Building B Trash Room Plans A5-97 Building B Trash Chute Sections A5-98 BUILDING B TRASH CHUTE SECTIONS A7-00 Dwelling Unit Door Schedule A7-10 Building A Door Schedule A7-20 Building B Door Schedule A7-30 Vinyl Window Schedule A7-40 Storefront Schedule A7-50 Finish Schedule AD-01 ACCESSIBLE ROUTES, PARKING NOTES AND DETAILS AD-02 COMMON & PUBLIC AREA ACCESSIBILITY NOTES & DETAILS AD-02.1 COMMON & PUBLIC AREA ACCESSIBILITY NOTES & DETAILS (2) AD-03 DWELLING UNIT ACCESSIBILITY DETAILS AD-04 ELEVATOR DETAILS AD-20 FIRE ASSEMBLY PENETRATION KEY PLAN AD-20.2 ACOUSTICAL ISOLATION DETAILS AD-20.1 FIRE PENETRATION DETAILS AD-21 FIRE-RATED FLOOR-CEILING ASSEMBLIES AD-22 FIRE-RATED INTERIOR WALL ASSEMBLIES AD-22.1 1-HOUR FIRE PARTITION DETAILS AD-23 2-HOUR FIRE BARRIER DETAILS AD-24 FIRE-RATED EXTERIOR WALL DETAILS AD-25 3-HR RATED FIRE WALL DETAILS AD-26 3-HOUR FIRE BARRIER AT GREASE SHAFT DETAILS AD-27 TILT-UP WALL AT GARAGE AD-28 FIRE-RATED PRIMARY STRUCTURAL FRAME DETAILS AD-31 GARAGE DETAILS AD-32 SLAB ON GRADE DETAILS AD-33 EXPANSION JOINT DETAILS AD-41 ELEVATED SLAB DETAILS AD-41.1 EXTERIOR IMPERVIOUS SURFACE (CON-DEK) AD-51.0 EXTERIOR WALL FLASHING DETAILS AT STUCCO AD-51.1 EXTERIOR WALL FLASHING DETAILS AT STUCCO AD-52.0 EXTERIOR DOOR FLASHING DETAILS AT STUCCO AD-52.1 EXTERIOR DOOR FLASHINIG DETAILS AD-52.2 INTERIOR DOOR DETAILS AD-53 WINDOW DETAILS (FLUSH CONDITION) AD-54 WINDOW DETAILS (RECESSED CONDITION) AD-55 EXTERIOR IMPERVIOUS SURFACE (PLI-DEK) AD-56 EXTERIOR DECK WITH HARDROCK CONCRETE TOPPING AD-61.0 TPO ROOFING DETAILS AD-61.1 TPO ROOFING DETAILS AD-61.2 CONCRETE FLAT TILE ROOF DETAILS AD-71 INTERIOR STAIR DETAILS (STEEL STRINGER & PRE-CAST) AD-71.1 INTERIOR STAIR DETAILS (WOOD) AD-81 STOREFRONT DETAILS (Flush Conditions) AD-82 STOREFRONT DETAILS (Recessed Conditions) City Council 23 – 1312/6/2022 A0-02 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed.
Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL SHEET INDEX SHEET INDEX SHEET INDEX COPYRIGHT C SHEET INDEX SHEET INDEX SHEET INDEX SHEET INDEX STRUCTURAL S0-00 STRUCTURAL GENERAL NOTES S0-01 STRUCTURAL GENERAL NOTES S0-02 STRUCTURAL GENERAL NOTES, LEGENDS, ABBREVIATIONS & SHEET LIST S2-11N FOUNDATION PLAN-NORTH S2-11N-SSW LEVEL 1 STUD AND SHEAR WALL PLAN-NORTH S2-11S FOUNDATION PLAN-SOUTH S2-12N LEVEL 2 MILD REINFORCING AND FRAMING PLAN-NORTH S2-12N-PT LEVEL 2 POST-TENSIONED FRAMING & STUD AND SHEAR WALL PLAN-NORTH S2-12S LEVEL 2 MILD REINFORCING PLAN-SOUTH S2-12S-PT LEVEL 2 POST-TENSIONED FRAMING PLAN-SOUTH S2-13N LEVEL 3 MILD REINFORCING AND FRAMING PLAN-NORTH S2-13N-PT LEVEL 3 POST-TENSIONED FRAMING & STUD AND SHEAR WALL PLAN-NORTH S2-13S LEVEL 3 MILD REINFORCING PLAN-SOUTH S2-13S-PT LEVEL 3 POST-TENSIONED FRAMING PLAN-SOUTH S2-13S-SSW LEVEL 3 STUD AND SHEAR WALL PLAN-SOUTH S2-14N LEVEL 4 MILD REINFORCING AND FRAMING PLAN-NORTH S2-14N-PT LEVEL 4 POST-TENSIONED FRAMING & STUD AND SHEAR WALL PLAN-NORTH S2-14S LEVEL 4 FRAMING PLAN-SOUTH S2-14S-SSW LEVEL 4 STUD AND SHEAR WALL PLAN-SOUTH S2-15N LEVEL 5 FRAMING PLAN-NORTH S2-15N-SSW LEVEL 5 STUD AND SHEAR WALL PLAN-NORTH S2-15S LEVEL 5 FRAMING PLAN-SOUTH S2-15S-SSW LEVEL 5 STUD AND SHEAR WALL PLAN-SOUTH S2-16N LEVEL 6 ROOF FRAMING PLAN-NORTH S2-16S LEVEL 6 FRAMING PLAN-SOUTH S2-16S-SSW LEVEL 6 STUD AND SHEAR WALL PLAN-SOUTH S2-17S LEVEL 7 FRAMING PLAN-SOUTH S2-17S-SSW LEVEL 7 STUD AND SHEAR WALL PLAN-SOUTH S2-18S ROOF FRAMING PLAN-SOUTH S2-51N FOUNDATION PLAN-NORTH S2-51N-SSW LEVEL 1 STUD AND SHEAR WALL PLAN-NORTH S2-51S FOUNDATION PLAN-SOUTH S2-51S-SSW LEVEL 1 STUD AND SHEAR WALL PLAN-SOUTH S2-52N LEVEL 2 MILD REINFORCING AND FRAMING PLAN-NORTH S2-52N-PT LEVEL 2 POST-TENSIONED FRAMING & STUD AND SHEAR WALL PLAN-NORTH S2-52S LEVEL 2 FRAMING PLAN-SOUTH S2-52S-SSW LEVEL 2 STUD AND SHEAR WALL PLAN-SOUTH S2-53N LEVEL 3 MILD REINFORCING AND FRAMING PLAN-NORTH S2-53N-PT LEVEL 3 POST-TENSIONED FRAMING & STUD AND SHEAR WALL PLAN-NORTH S2-53S LEVEL 3 FRAMING PLAN-SOUTH S2-53S-SSW LEVEL 3 STUD AND SHEAR WALL PLAN-SOUTH S2-54N LEVEL 4 MILD REINFORCING AND FRAMING PLAN-NORTH S2-54N-PT LEVEL 4 POST-TENSIONED FRAMING & STUD AND SHEAR WALL PLAN-NORTH S2-54S LEVEL 4 FRAMING PLAN-SOUTH S2-54S-SSW LEVEL 4 STUD AND SHEAR WALL PLAN-SOUTH S2-55N LEVEL 5 FRAMING PLAN-NORTH S2-55N-SSW LEVEL 5 STUD AND SHEAR WALL PLAN-NORTH S2-55S LEVEL 5 FRAMING PLAN-SOUTH S2-55S-SSW LEVEL 5 STUD AND SHEAR WALL PLAN-SOUTH S2-56N ROOF FRAMING PLAN-NORTH S2-56S ROOF FRAMING PLAN-SOUTH S3-01 STRUCTURAL FOUNDATION DETAILS S3-02 STRUCTURAL FOUNDATION DETAILS S3-03 STRUCTURAL FOUNDATION DETAILS S3-04 FOUNDATION DETAILS S4-01 CONCRETE FRAMING DETAILS S5-01 WOOD FRAMING DETAILS S5-02 WOOD FRAMING DETAILS S5-03 WOOD FRAMING DETAILS MECHANICAL M-0.0 HVAC NOTES & RESIDENTIAL EQUIPMENT SCHEDULES M-0.1 HVAC DETAILS M-1.0 HVAC BUILDING A LEVEL 1 M-1.1 HVAC BUILDING B LEVEL 1 M-2.1 HVAC BUILDING A LEVEL 2 M-2.2 HVAC BUILDING B LEVEL 2 M-3.1 HVAC BUILDING A LEVEL 3 M-3.2 HVAC BUILDING B LEVEL 3 M-4.1 HVAC BUILDING A LEVEL 4 M-4.2 HVAC BUILDING B LEVEL 4 M-5.1 HVAC BUILDING A LEVEL 2 M-5.2 HVAC BUILDING B LEVEL 5 M-6.1 HVAC BUILDING A LEVEL 6/LOWER ROOF A M-6.2 HVAC BUILDING B ROOF M-7.1 HVAC BUILDING A LEVEL 7 M-7.2 HVAC BUILDING A ROOF M-8.1 HVAC ENLARGED UNIT PLANS P0-1A, 1B, 1C, P0-2, P0-3A & P0-3B M-8.2 HVAC ENLARGED UNIT PLANS P1-1A, P1-1B, P1-2 & P1-4A M-8.3 HVAC ENLARGED UNIT PLANS P2-1A, P2-1B, P2-2A & P2-2B M-8.4 HVAC ENLARGED UNIT PLANS P2-3A, P2-3B, P2-4A & P2-5A M-8.5 HVAC ENLARGED UNIT PLANS P3-1A, P3-1B, P3-2A & P3-2B M-8.6 HVAC ENLARGED UNIT PLANS P3-2C, P3-3, P4-1B & P4-1C M-8.7 HVAC ENLARGED UNIT PLANS P4-1E & P4-2 ELECTRICAL BUILDING A E -0.0 ELECTRICAL COVER SHEET E-0.1 ELECTRICAL SINGLE LINE DIAGRAM E-0.2 PARTIAL SINGLE LINE DIAGRAM E-0.3 LOAD CALCULATIONS E-1.0 1ST FLOOR ELECTRICAL PLAN E-2.0 2ND FLOOR ELECTRICAL PLAN E-3.0 3RD FLOOR ELECTRICAL PLAN E-4.0 4TH FLOOR ELECTRICAL PLAN E-5.0 5TH FLOOR ELECTRICAL PLAN E-6.0 6TH FLOOR ELECTRICAL PLAN E-7.0 7TH FLOOR ELECTRICAL PLAN BUILDING B E -0.0 ELECTRICAL COVER SHEET E-0.1 ELECTRICAL SINGLE LINE DIAGRAM E-0.2 PARTIAL SINGLE LINE DIAGRAM E-0.3 LOAD CALCULATIONS E-1.0 1ST FLOOR ELECTRICAL PLAN E-2.0 2ND FLOOR ELECTRICAL PLAN E-3.0 3RD FLOOR ELECTRICAL PLAN E-4.0 4TH FLOOR ELECTRICAL PLAN E-5.0 5TH FLOOR ELECTRICAL PLAN PLUMBING PA0-0A PLUMBING NOTES/SCHEDULES, SHEET INDEX PA0-0B PLUMBING DETAILS/NOTES PA0-1 PLUMBING SITE PLAN PA1-0 BUILDING A - UNDERGROUND WASTE PA1-1 BUILDING A - LEVEL 1 WASTE PA1-2 BUILDING A - LEVEL 2 WASTE PA1-3 BUILDING A - LEVEL 3 WASTE PA1-4 BUILDING A - LEVEL 4 WASTE PA1-5 BUILDING A - LEVEL 5 WASTE PA1-6 BUILDING A - LEVEL 6 WASTE PA1-7 BUILDING A - LEVEL 7 WASTE PA1-8 BUILDING A - ROOF WASTE PA1-9A BUILDING A - WASTE RISERS PA1-9B BUILDING A - WASTE RISERS PA2-0 BUILDING A - UNDERGROUND WATER & GAS PA2-1 BUILDING A - LEVEL 1 WATER & GAS PA2-2 BUILDING A - LEVEL 2 WATER & GAS PA2-3 BUILDING A - LEVEL 3 WATER & GAS PA2-4 BUILDING A - LEVEL 4 WATER & GAS PA2-5 BUILDING A - LEVEL 5 WATER & GAS PA2-6 BUILDING A - LEVEL 6 WATER & GAS PA2-7 BUILDING A - LEVEL 7 WATER & GAS PA2-8 BUILDING A - ROOF WATER & GAS PA2-9A BUILDING A - WATER RISERS PA4-1 BUILDING A - ENLARGED UNITS PA4-2 BUILDING A - ENLARGED UNITS PA4-3 BUILDING A - ENLARGED UNITS PA4-4 BUILDING A - ENLARGED UNITS PB0-0A PLUMBING NOTES/SCHEDULES, SHEET INDEX PB0-0B PLUMBING DETAILS/NOTES PB0-0C PLUMBING DETAILS/NOTES PB0-0D PLUMBING DETAILS/NOTES PB0-1 PLUMBING SITE PLAN PB1-0 BUILDING B - UNDERGROUND WASTE PB1-1 BUILDING B - LEVEL 1 WASTE PB1-2 BUILDING B - LEVEL 2 WASTE PB1-3 BUILDING B - LEVEL 3 WASTE PB1-4 BUILDING B - LEVEL 4 WASTE PB1-5 BUILDING B - LEVEL 5 WASTE PB1-6 BUILDING B - ROOF WASTE PB1-7A BUILDING B - WASTE RISERS PB1-7B BUILDING B - WASTE RISERS PB1-7C BUILDING B - WASTE RISERS PB2-0 BUILDING B - UNDERGROUND WATER & GAS PB2-1 BUILDING B - LEVEL 1 WATER & GAS PB2-2 BUILDING B - LEVEL 2 WATER & GAS PB2-3 BUILDING B - LEVEL 3 WATER & GAS PB2-4 BUILDING B - LEVEL 4 WATER & GAS PB2-5 BUILDING B - LEVEL 5 WATER & GAS PB2-6 BUILDING B - ROOF WATER & GAS PB2-7A BUILDING B - WATER RISERS PB2-7B BUILDING B - WATER RISERS PB2-7C BUILDING B - GAS RISERS PB4-1 BUILDING B - ENLARGED UNITS PB4-2 BUILDING B - ENLARGED UNITS PB4-3 BUILDING B - ENLARGED UNITS PB4-4 BUILDING B - ENLARGED UNITS LOW VOLTAGE BUILDING A RESCUE ASSISTANCE 2-WAY COMMUNICATIONS SYSTEM RA-101 COVER SHEET RA-102 SYMBOL AND CABLING LEGEND RA-501 BUILDING A FIRST LEVEL FLOOR PLAN RA-502 BUILDING A SECOND LEVEL FLOOR PLAN RA-503 BUILDING A THIRD LEVEL FLOOR PLAN RA-504 BUILDING A FOURTH LEVEL FLOOR PLAN RA-505 BUILDING A FIFTH LEVEL FLOOR PLAN RA-506 BUILDING A SIXTH LEVEL FLOOR PLAN RA-507 BUILDING A SEVENTH LEVEL FLOOR PLAN RA-508 BUILDING A ROOF PLAN BUILDING A EMERGENCY RESPONDER RADIO COVERAGE SYSTEM ERRCS-101 COVER SHEET ERRCS-201 DETAILS ERRCS-301 RISER DIAGRAM ERRCS-401 SITE PLAN ERRCS-501 FIRST LEVEL ERRCS-502 SECOND LEVEL ERRCS-503 THIRD LEVEL ERRCS-504 FOURTH LEVEL ERRCS-505 FIFTH LEVEL ERRCS-506 SIXTH LEVEL ERRCS=507 SEVENTH LEVEL ERRCS-508 ROOF BUILDING A LOW VOLTAGE STRUCTURED CABLING SYSTEM LVSC-101 BUILDING A COVER SHEET LVSC-301 RISER DIAGRAM LVSC-501 BUILDING A FIRST LEVEL FLOOR PLAN LVSC-502 BUILDING A SECOND LEVEL FLOOR PLAN LVSC-503 BUILDING A THIRD LEVEL FLOOR PLAN LVSC-504 BUILDING A FOURTH LEVEL FLOOR PLAN LVSC-505 BUILDING A FIFTH LEVEL FLOOR PLAN LVSC-506 BUILDING A SIXTH LEVEL FLOOR PLAN LVSC-507 BUILDING A SEVENTH LEVEL FLOOR PLAN LVSC-508 BUILDING A ROOF LEVEL FLOOR PLAN BUILDING B RESCUE ASSISTANCE 2-WAY COMMUNICATIONS SYSTEM RA-101 COVER SHEET RA-102 SYMBOL AND CABLING LEGEND RA-501 BUILDING B FIRST LEVEL FLOOR PLAN RA-502 BUILDING B SECOND LEVEL FLOOR PLAN RA-503 BUILDING B THIRD LEVEL FLOOR PLAN RA-504 BUILDING B FOURTH LEVEL FLOOR PLAN RA-505 BUILDING B FIFTH LEVEL FLOOR PLAN RA-506 BUILDING B ROOF LEVEL FLOOR PLAN BUILDING B EMERGENCY RESPONDER RADIO COVERAGE SYSTEM ERRCS-101 COVER SHEET ERRCS-201 DETAILS ERRCS-301 RISER DIAGRAM ERRCS-401 SITE PLAN ERRCS-501 FIRST LEVEL ERRCS-502 SECOND LEVEL ERRCS-503 THIRD LEVEL ERRCS-504 FOURTH LEVEL ERRCS-505 FIFTH LEVEL ERRCS-506 ROOF BUILDING B LOW VOLTAGE STRUCTURED CABLING SYSTEM LVSC-101 BUILDING A COVER SHEET LVSC-301 RISER DIAGRAM LVSC-501 BUILDING B FIRST LEVEL FLOOR PLAN LVSC-502 BUILDING B SECOND LEVEL FLOOR PLAN LVSC-503 BUILDING B THIRD LEVEL FLOOR PLAN LVSC-504 BUILDING B FOURTH LEVEL FLOOR PLAN LVSC-505 BUILDING B FIFTH LEVEL FLOOR PLAN LVSC-506 BUILDING B ROOF LEVEL FLOOR PLAN LANDSCAPE LTS-01 LANDSCAPE TITLE SHEET LCP-01 LANDSCAPE CONSTRUCTION PLAN LCP-02 LANDSCAPE CONSTRUCTION PLAN LCP-03 LANDSCAPE CONSTRUCTION PLAN LHP-01 LANDSCAPE HORIZONTAL CONTROL PLAN LHP-02 LANDSCAPE HORIZONTAL CONTROL PLAN LHP-03 LANDSCAPE HORIZONTAL CONTROL PLAN LCM-01 LANDSCAPE CONSTRUCTION MATERIALS LCD-01 LANDSCAPE CONSTRUCTION DETAILS LCD-02 LANDSCAPE CONSTRUCTION DETAILS LCD-03 LANDSCAPE CONSTRUCTION DETAILS LCD-04 LANDSCAPE CONSTRUCTION DETAILS LCD-05 LANDSCAPE CONSTRUCTION DETAILS LCD-06 LANDSCAPE CONSTRUCTION DETAILS LCD-07 LANDSCAPE CONSTRUCTION DETAILS LCS-01 LANDSCAPE CONSTRUCTION NOTES & SPECIFICATIONS LPP-01 LANDSCAPE PLANTING PLAN LPP-02 LANDSCAPE PLANTING PLAN LPP-03 LANDSCAPE PLANTING PLAN LPD-01 LANDSCAPE PLANTING DETAILS LPD-02 LANDSCAPE PLANTING DETAILS LPS-01 LANDSCAPE PLANTING NOTES & SPECIFICATIONS EBM EBM0.0 SITE PLAN & GENERAL NOTES EBM1.0A COMPOSITE ROOF PLAN A EBM1.0 COMPOSITE ROOF PLAN B EBM2.0A NORTH & EAST EXTERIOR ELEVATIONS BLDG. A EBM2.1A WEST & SOUTH EXTERIOR ELEVATIONS BLDG. A EBM2.2B WEST & SOUTH EXTERIOR ELEVATIONS BLDG. B EBM2.3B NORTH & EAST EXTERIOR ELEVATIONS BLDG. B EBM4.0 SECTIONS & DETAILS EBM5.0 OPERABLE WINDOW PARAMETERS City Council 23 – 1412/6/2022
COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL CODE & PROJECT SUMMARIESA0-02 CODE ANALYSIS DATA CODE COMPLIANCE THIS PROJECT SHALL COMPLY WITH ALL OTHER REGULATIONS AND ORDINANCES ADOPTED BY THE STATE GOVERNING AGENCIES. APPLICABLE CODES: 2019 EDITION OF THE CALIFORNIA BUILDING CODE (CBC) 2019 EDITION OF THE CALIFORNIA MECHANICAL CODE (CMC) 2019 EDITION OF THE CALIFORNIA PLUMBING CODE (CPC) 2019 EDITION OF THE CALIFORNIA ELECTRICAL CODE (CEC) 2019 EDITION OF THE CALIFORNIA FIRE CODE 2019 EDITION OF THE CALIFORNIA ENERGY CODE 2019 EDITION OF THE CALIFORNIA GREEN BUILDING CODE PROJECT DESCRIPTION PROPOSED ARE 2 RESIDENTIAL APARTMENT BUILDINGS CONSISTING OF THE FOLLOWING: BUILDING A: · (1) TYPE I-A GARAGE & RESIDENTIAL BUILDING, 6 UNITS, 5 AT GRADE LEVELS · (1) TYPE III-A RESIDENTIAL BUILDING, 73 UNITS, 5 LEVELS ABOVE PODIUM· FIREWALLS ARE USED TO SEPARATE THE BUILDING ABOVE THE PODIUM INTO 3 BUILDING PORTIONS· (1) TYPE III-A RESIDENTIAL BUILDING, 20 UNITS, 5 LEVELS AT GRADE· BUILDINGS COMPLY WITH CBC SECTION 510.2 AND 705.3 EXCEPTION 2· FIRE SPRINKLER SYSTEM: NFPA-13 BUILDING B: · (1) TYPE I-A GARAGE BUILDING, 4 AT GRADE LEVELS
· (1) TYPE III-A RESIDENTIAL BUILDING, 70 UNITS, 5 LEVELS AT GRADE· FIREWALLS ARE USED TO SEPARATE THE BUILDING AT GRADE INTO 3 BUILDING PORTIONS· BUILDINGS COMPLY WITH CBC SECTION 705.3 EXCEPTION 2· FIRE SPRINKLER SYSTEM: NFPA-13 BUILDING & UNIT SUMMARY FIRE-RESISTANCE RATING FOR BUILDING ELEMENTS (HOURS) - CBC TABLE 601 BUILDING ELEMENTS TYPE OF CONSTRUCTION IA IIIA PRIMARY STRUCTURAL FRAME (CBC 202 and 704) 3 1 BEARING WALLS-EXTERIOR 3 2 BEARING WALLS-INTERIOR 3 1 NONBEARING WALLS AND PARTITIONS -EXTERIOR CBC TABLE 602 NONBEARING WALLS AND PARTITIONS -INTERIOR 0 0 FLOOR AND ASSOCIATE SECONDARY MEMBERS 2 1 ROOF AND ASSOCIATE SECONDARY MEMBERS 1 1/2 1 SEPARATED OCCUPANCIES OCCUPANCY TYPE R-2 S-2 B
A
M SEPARATION OF OCCUPANCIES (CBC TABLE 508.4) R-2 to S-2: 1-HR R-2 to B: 1-HR R-2 to A: 1-HR R-2 to M: 1-HR S-2 to R-2: 1-HR S-2 to B: 1-HR S-2 to A: None S-2 to M: 1-HR B to R-2: 1-HR B to S-2: 1-HR B to A: 1-HR B to M: None A to R-2: 1-HR A to S-2: None A to B: 1-HR A to M: 1-HR M to R-2: 1-HR M to S-2: 1-HR M to B: None M to A: 1-HR BUILDING A AREA SUMMARY FLOOR LEVEL TOTAL AREA (SF) FIRST LEVEL (01) GARAGE 22,472 FIRST LEVEL (01) LEASING 2,337 FIRST LEVEL (01) AMENITIES 3,211 FIRST LEVEL (01) RETAIL 12,113 FIRST LEVEL (01) RESIDENTIAL 10,493 50,626 SECOND LEVEL (02) GARAGE 21,335 SECOND LEVEL (02) AMENITIES 4,088 SECOND LEVEL (02) RESIDENTIAL 10,956 SECOND LEVEL (02) STORAGE 1,991 38,370 THIRD LEVEL (03) GARAGE 21,335 THIRD LEVEL (03) AMENITIES 15,526 THIRD LEVEL (03) RESIDENTIAL 21,325 58,186 FOURTH LEVEL (04) GARAGE 21,335 FOURTH LEVEL (04) RESIDENTIAL 21,325 42,660 FIFTH LEVEL (05) GARAGE 21,335 FIFTH LEVEL (05) RESIDENTIAL 23,644 44,979 SIXTH LEVEL (06) RESIDENTIAL 23,644 SEVENTH LEVEL (07) AMENITIES 750 SEVENTH LEVEL (07) RESIDENTIAL 22,894 23,644 TOTAL BUILDING AREA 282,109 SITE AREA 61,989 F.A.R. 4.55 RESIDENTIAL 135,031 PARKING 107,812 RETAIL 12,113 LEASING 2,337 AMENITIES 7,299 BUILDING B AREA SUMMARY FLOOR LEVEL TOTAL AREA (SF) FIRST LEVEL (01) GARAGE 21,550 FIRST LEVEL (01) RESIDENTIAL 20,501 42,051 SECOND LEVEL (02) GARAGE 21,550 SECOND LEVEL (02) RESIDENTIAL 20,501 42,051 THIRD LEVEL (03) GARAGE 21,550 THIRD LEVEL (03) RESIDENTIAL 20,501 42,051 FOURTH LEVEL (04) GARAGE 21,550 FOURTH LEVEL (04) RESIDENTIAL 20,501 42,051 FIFTH LEVEL (05) RESIDENTIAL 20,501 TOTAL BUILDING AREA 188,705 SITE AREA 55,828 F.A.R. 3.38 RESIDENTIAL 102,505 PARKING 86,200 RETAIL 0 LEASING0 AMENITIES0 PLUMBING FIXTURES REQUIREMENTS FOR COMBINED OCCUPANCY - BLDG A LEVEL 3 POOL DECK & CLUBROOM (CPC 2019 SECTION 422.1) Occupancy group Total area (in S.F.) Number of occupants (50%)Number of drinking fountains Service sink* Pool Showers Number of toilets (women) Number of toilets (men) Number of urinals Number of lavatories (women) Number of lavatories (men) A-3 4,975 83 0.33 1 NA 2.49 0.83 0.83 0.83 0.42 Pool/Spa 1,277 86 0.34 NA 1.72 0.72 0.57 0.57 0.54 0.54 43 Total 1 1 2 4 2
2 2 1 NOTE: IN BUSINESS AND MERCANTILE OCCUPANCIES WITH 50 OR FEWER PERSONS, ONE SINGLE USE (UNISEX) TOILET FACILITY MAY BE PROVIDED IN OCCUPANCIES WITH 10 OR FEWER PERSONS, ONE SINGLE USE (UNISEX) TOILET FACILITY MAY BE PROVIDED * IN COMBINED OCCUPANCY FACILITIES, MIN. ONE SERVICE SINK SHALL BE PROVIDED PLUMBING FIXTURES REQUIREMENTS FOR BUSINESS OCCUPANCY (B) (CPC 2019 TABLE 422.1) LEVEL 1 LEASING & CO-WORKING Total area (in S.F.) Number of occupants (50%) (200 load factor) Number of drinking fountains Service sink Number of toilets (women) Number of toilets (men) Number of urinals Number of lavatories (women) Number of lavatories (men) 3,000 8 1 1 1 1 1 1 1 PLUMBING FIXTURES REQUIREMENTS FOR ASSEMBLY OCCUPANCY (A-3) (CPC 2019 TABLE 422.1) LEVEL 1 FITNESS Total area (in S.F.) Number of occupants (50%) (30 load factor) Number of drinking fountains Service sink Number of toilets (women) Number of toilets (men) Number of urinals Number of lavatories (women) Number of lavatories (men) 2,300 39 1 1 2 1 1 1 1 PRIVATE OPEN SPACE UNIT TYPE UNIT DECK FLOOR AREA (SF) NUMBER OF UNITS TOTAL (SF) 1 BEDROOM P1.1A 68 1 68 P1.1B 68 4 272 P1.1C 68 1 68 P1.1D 684 272 P1.1E 68
2 136 P1.1G 66 1 66 P1.1H 66 1 66 P1.1K 66
4 264 P1.3A 84 1 84 2 BEDROOM P2.1B 74
2 148 P2.1C 742 148 P2.1D 84 1 84 P2.1E 742 148 P2.1F 742 148 P2.1G 68 1 68 P2.1H 742 148 P2.1J 68 4 272 P2.2B 773 231 P2.2C 77 1 77 P2.2D 743 222 P2.2E 74 2 148 P2.2F 77 1 77 P2.2G 67 1 67 P2.2H 67 1 67 P2.2J 672 134 P2.2K 67 1 67 P2.2L 84 1 84 P2.2M 84 3 252 P2.2N 84 1 84 P2.2P 634 252 P2.2Q 63 1 63 TOTAL PRIVATE OPEN SPACE PROVIDED (SF) 4,285 TOTAL PRIVATE OPEN SPACE REQUIRED (SF) 8,450 DEFICIT (TO BE MADE UP BY COMMON INTERIOR) 4,165 COMMON INTERIOR OPEN SPACE (SF) CLUBROOM 1791 YOGA 499 FITNESS 1436 CO-WORKING 2602 TOTAL COMMON INTERIOR OPEN SPACE 6328 PUBLIC OPEN SPACE - BLDG A AREA LANDSCAPE (SF) HARDSCAPE (SF) TOTAL (SF) SETBACK 5483 2887 8370 LEVEL 3 RECREATION 1002 5744 6746 ROOF DECK 95 862 957 TOTAL PROVIDED (SF) 6580 9493 16073 TOTAL REQUIRED - 15% OF SITE (SF) 9298 PUBLIC OPEN SPACE - BLDG B AREA LANDSCAPE (SF) HARDSCAPE (SF) TOTAL (SF) SETBACK & COURTYARD 8320 4021 12341 TOTAL PROVIDED (SF) 8320 4021 12341 TOTAL REQUIRED - 15% OF SITE (SF) 8374 City Council 23 – 1512/6/2022
G R W SP SP
LV ELEC
LV
ELEC
LV
ELEC
LV ELEC
LV ELEC LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC UPDN UP STAIR A1 UP 5%
UP 5.0% UP 5% DOWN 5% EV
EV EV EV
FEC
EV
FEC FEC FEC
DOWN 1.5% ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ ñ
ñ ñ UP DN DNUP DN UP (2)WARMING D/W ICE REF U/C MICRO DRAWERS TRASHRECY FEC
FEC FEC
FEC A-3 1883 SQ. FT. R-2 8090 SQ. FT. AREA "A1" 9,973 SQ. FT. AREA "A2" 9971 SQ. FT.AREA "A3" 3863 SQ. FT. PARKING GARAGE TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED
G R W SP SP
LV ELEC
LV
ELEC
LV
ELEC
LV ELEC
LV ELEC LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC DN UP STAIR A1 UP 5%
UP 5% UP 5% DOWN 5%
FEC FEC FEC FEC
DOWM 1.5% ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ LV
ELEC UP DN DNUP DN UP SP
FEC
FEC FEC
FEC AREA "A1" 8140 SQ. FT. AREA "A2" 10111 SQ. FT.AREA "A3" 3863 SQ. FT. PARKING GARAGE TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED
G R W SP SP
LV ELEC
LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC TURN- AROUND SPOT
UP 5% UP 5% DOWN 5%
FEC
DOWN 1.6% ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ LV ELEC UP DN DN DNUP
LV ELEC
LV
ELEC
LV
ELEC
FEC
FEC FEC
FEC AREA "A1" 10065 SQ. FT. AREA "A2" 10111 SQ. FT.AREA "A3" 3863 SQ. FT. PARKING GARAGE TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED
G R W SP SP
LV ELEC
LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC TURN- AROUND SPOT UP DN DNUP
FEC FEC FEC AREA "A1" 10071 SQ. FT. AREA "A2" 8633 SQ. FT.
G R W SP SP
LV ELEC
ELEC
LV LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC LV ELEC LV ELEC
LV
ELEC DN DN
LV ELEC SP
FEC FEC FEC R-2 8489 SQ. FT. AREA "A2" 8633 SQ. FT.
B 1084 SQ. FT. AREA "A1" 9,573 SQ. FT.
LV ELEC STORAGE
LV ELEC
LV
ELEC
LV
ELEC
LV
ELEC LV ELEC
ELEC
ELEC
VAN OPEN TO BELOW STAIR A1 UP 5%
UP 5% UP 5%
UP 4.3% DOWN 5%
EV EV EV EV EV EV EV UP DN UP
FEC
FEC FECFEC
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ CORRIDOR VENTILATION SHAFT (2) FUTURE GREASE SHAFTS ABOVE CORRIDOR VENTILATION SHAFT STAIR A4 STAIR A3 ELEV A2 G R W STAIR A2 ELEV A1IDF CORRIDOR VENTILATION SHAFT DN UP DNUP IDF DN UP
SHELVING RETAIL/RESTUARANT UTILITY CLOSET POOL EQUIPMENT STORAGE MAINTENANCE SHARED GOODS COMMON OPS BREAK ROOM SPSP
FEC
FEC
FEC DN
4.5% YOGA STUDIO YOGA STORAGE WOMENS RESTROOM MENS RESTROOM OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW AREA "A3" 3863 SQ. FT. AREA "A2" 1423 SQ. FT. PARKING GARAGE TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED 2 STORY CONCRETE PODIUM TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED LV ELEC RETAIL RESTAURANT KITCHEN/ STORAGE PUBLIC LOBBY
LV ELEC
LV
ELEC
LV
ELEC CORRIDOR VENTILATION SHAFT (2) FUTURE GREASE SHAFTS ABOVE CORRIDOR VENTILATION SHAFT UP UP UP UP UP TURN-AROUND SPOT TRASH / LOADING VAN BIKE FIRE PUMP ROOM BOOSTER PUMP ROOM STAIR A1 STAIR A2 TURN AROUND SPOT VAN VAN UP 5%UP 5% UP 2%
UP 5%
EV EV EV DN 4.5%
FEC
FEC FEC
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ PARCEL ROOM STAIR A4 STAIR A3
LV
ELEC ELEV A1 ELEV A2 IDF CORRIDOR VENTILATION SHAFT UP
DN 2.2% UP UP UP MPOE DN 4.5% 1.8% DN DN
1.8% DN 1.5%DN 4.5% DN
4.5% DN
1.3% DN 1.5% DN
4.5% TV
TRASH RECY
REF SP SP
W R F
FEC
FEC
FEC
ELEC UP FITNESS LEASING OFFICE TRASH VESTIBULE PARKING GARAGE TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED AREA "A3" 3863 SQ. FT. AREA "A2" 1423 SQ. FT. 2 STORY CONCRETE PODIUM TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed.
Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A ALLOWABLE AREA CALCULATIONS A0-03A BUILDING A LEVEL 3 SCALE: 1/32"=1'-0" 3 BUILDING A LEVEL 4 SCALE: 1/32"=1'-0"
4 BUILDING A LEVEL 5 SCALE: 1/32"=1'-0"
5 BUILDING A LEVEL 6 SCALE: 1/32"=1'-0"6 BUILDING A LEVEL 7 SCALE: 1/32"=1'-0"7 BUILDING A LEVEL 1 SCALE: 1/32"=1'-0" 1 BUILDING A LEVEL 2 SCALE: 1/32"=1'-0"
2 City Council 23 – 1612/6/2022
SP SP LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
ELEC LV LV
ELEC LV
ELEC
LV ELEC
LV
ELEC UP UP UP UP UP
R
W TRASH / LOADING UP 5%
UP 5% BIKE STORAGE ROOM FIRE PUMP ROOM BOOSTER PUMP ROOM VAN UP 5% UP 6.2% UP 2%
G MAILROOM PARCEL
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC
FEC TRASH VESTIBULE ELECTRICAL ROOM STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 LV ELEC MPOE IDF UP DN 6.5% UP DN UP UP
DN 2% UP
G G
DN 8%
DN 4.67%
ELEC UP DN 4.67% DN 4.67%
DN 4.67% STORAGE PARKING GARAGE TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED AREA "B1" 3203 SQ. FT. AREA "B2" 9805 SQ. FT. AREA "B3" 7354 SQ. FT. SP SP LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
ELEC LV LV
ELEC
LV ELEC
R W G UP 5% RAMP UP 93' (RUN) (5% SLOPE) = 4.65' (RISE) UP 3.5% DN 5% OPEN TO BELOW VAN
UP 5% UP DN UP EV EV EV EV
EV
EV EV EV
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC
FEC FEC LV ELEC LV ELEC
LV ELEC STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 IDF UPDN LV
ELEC UP UP DN DNUP TRASH VESTIBULE PARKING GARAGE TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED AREA "B1" 3203 SQ. FT. AREA "B2" 9944 SQ. FT. AREA "B3" 7557 SQ. FT. SP SP LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELECLV ELEC
LV ELEC
LV
ELEC
ELEC LV LV
ELEC
LV ELEC
R W G UP 5% UP 5%
UP 3.5% DN 5% UP DN UP EV EV EV
ñ ñ
ñ ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ ñ
FEC FEC
FEC FEC LV ELEC LV ELEC
LV ELEC STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 UPDN IDF DNUP UP UP DN TRASH VESTIBULE PARKING GARAGE TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED AREA "B1" 3203 SQ. FT. AREA "B2" 9944 SQ. FT. AREA "B3" 7557 SQ. FT. SP SP LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
LV
ELEC
ELEC LV LV
ELEC
LV ELEC LV ELEC LV ELEC
LV ELEC STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 UPDN IDF DN UP UP UP DN R W G RAMP UP 93' (RUN) (5% SLOPE) = 4.65' (RISE)
UP 3.5% DN 5% UP 5% DN UP
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ ñ
FEC FEC TRASH VESTIBULE PARKING GARAGE TYPE IA CONSTRUCTION UNLIMITED AREA ALLOWED AREA "B1" 3203 SQ. FT. AREA "B2" 9944 SQ. FT. AREA "B3" 7557 SQ. FT. SP SP LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
LV
ELEC
ELEC LV LV
ELEC
LV ELEC LV ELEC LV ELEC
LV ELEC
R W G STAIR B1 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 DN ELEVATOR MACHINE ROOM DN DN TRASH VESTIBULE ROOF ACCESS AREA "B1" 3226 SQ. FT. AREA "B2" 9944 SQ. FT. AREA "B3" 7557 SQ. FT. COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed.
Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B ALLOWABLE AREA CALCULATIONS A0-03B BUILDING B LEVEL 1 SCALE: 1/32"=1'-0" 1 BUILDING B LEVEL 2 SCALE: 1/32"=1'-0"
2 BUILDING B LEVEL 3 SCALE: 1/32"=1'-0"
3 BUILDING B LEVEL 4 SCALE: 1/32"=1'-0"4 BUILDING B LEVEL 5 SCALE: 1/32"=1'-0" 5 NOT USED SCALE: 1/32"=1'-0"6
City Council 23 – 1712/6/2022
COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING AND UNIT SUMMARY A0-04 BUILDING B UNIT AREA SUMMARY UNIT TYPE UNIT FLOOR AREA (SF) DECK FLOOR AREA (SF) NUMBER OF UNITS TOTAL / UNIT TYPE TOTAL FLOOR AREA (SF) LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 STUDIO 5 P0.1A 453
0 - - - - -
0 0 P0.1B 454
0 - - - - -
0 0 P0.1C 453
0 - - - - -
0 0 P0.1D 453
0 - - - - -
0 0 P0.2A 510
0 1 1 1 1 1 5 2,550 P0.3A 5460 - - - - -
0 0 P0.3B 546
0 - - - - -
0 0 P0.3C 546
0 - - - - -
0 0 1 BEDROOM 12 P1.1A 698 68 - - - - -
0 0 P1.1B 700 68 - - - - -
0 0 P1.1C 701 68 - - - - -
0 0 P1.1D 698 68 - - - - -
0 0 P1.1E 701 68 - - - - -
0 0 P1.1F 690 61 1 1 1 1 -
4 2,760 P1.1G 701 66 1 - - - - 1 701 P1.1H 698 66 1 - - - - 1 698 P1.1J 690 61 - - - - 1 1 690 P1.1K 698 66 - 1 1 1 1 4 2,792 P1.2A 741 39 - - - - -0 0 P1.2B 741 37 - - - - -
0 0 P1.3A 723 84 - - - - -
0 0 P1.3B 723
0 1 - - - - 1 723 2 BEDROOM 28 P2.1B 1080 74 - - - - -
0 0 P2.1C 1080 74 - - - - -
0 0 P2.1D 1083 84 - - - - -
0 0 P2.1E 1083 74 - - - - -
0 0 P2.1F 1083 74 - - - - -
0 0 P2.1G 1081 68 - - - - -
0 0 P2.1H 1081 74 - - - - -
0 0 P2.1J 1079 68 - 1 1 1 1 4 4,316 P2.1L 1063 70 - - 1 1 - 2 2,126 P2.1P 1063 70 - - - - 1 1 1,063 P2.1Q 1063
0 - 1 - - - 1 1,063 P2.2B 1154 77 - - - - -
0 0 P2.2C 1154 77 - - - - -
0 0 P2.2D 1151 74 - - - - -
0 0 P2.2E 1151 74 - - - - -
0 0 P2.2F 1143 77 - - - - -
0 0 P2.2G 1150 67 1 - - - - 1 1,150 P2.2H 1150 67 - 1 - - - 1 1,150 P2.2J 1150 67 - - 1 1 - 2 2,300 P2.2K 1150 67 - - - - 1 1 1,150 P2.2L 1149 84 1 - - - - 1 1,149 P2.2M 1149 84 - 1 1 1 - 3 3,447 P2.2N 1149 84 - - - - 1 1 1,149 P2.2P 1152 63 1 1 1 1 -4 4,608 P2.2Q 1152 63 - - - - 1 1 1,152 P2.3A 998 0 1 - - - - 1 998 P2.3B 998 47 - 1 1 1 -
3 2,994 P2.3C 998 47 - - - - 1 1 998 P2.4A 932
0 - - - - -
0 0 P2.4B 932
0 - - - - -
0 0 P2.5A 1151 40 - - - - -
0 0 P2.5B 1151 37 - - - - -
0 0 P2.6A 1121
0 - - - - -
0 0 3 BEDROOM
6 P3.1A 938 57 1 - - - - 1 938 P3.1B 938 60 - 1 1 1 -
3 2,814 P3.1C 938 60 - - - - 1 1 938 P3.2A 1059
0 - - - - -
0 0 P3.2B 1055
0 - - - - -
0 0 P3.2C 1048
0 1 - - - - 1 1,048 P3.4A 10530 - - - - -
0 0 4 BEDROOM 19 P4.1A 1325 60 - - - - -
0 0 P4.1B 1325 49 - - - - -
0 0 P4.1C 1320 49 - - - - -
0 0 P4.1E 1288 44 - - - - -
0 0 P4.1F 1300
0 - - - - -
0 0 P4.1G 1290
0 - - - - -
0 0 P4.1H 1290 44 - - - - -
0 0 P4.1J 1293
0 - - - - -
0 0 P4.1K 1293 44 - - - - -
0 0 P4.1L 1296 60 1 - - - - 1 1,296 P4.1M 1296 63 - 1 1 1 - 3 3,888 P4.1N 1296 47 - 1 1 1 -3 3,888 P4.1P 1296 63 - - - - 1 1 1,296 P4.1Q 1296 47 - - - - 1 1 1,296 P4.2A 1494 87 2 - - - -
2 2,988 P4.2B 1494 87 -
2 2
2 2
8 11,952 TOTALS 14 14 14 14 14 70 74,069 BUILDING A UNIT AREA SUMMARY UNIT TYPE UNIT FLOOR AREA (SF) DECK FLOOR AREA (SF) NUMBER OF UNITS TOTAL / UNIT TYPE TOTAL FLOOR AREA (SF) LEVEL 1 LEVEL 2 LEVEL 3 LEVEL 4 LEVEL 5 LEVEL 6 LEVEL 7 STUDIO 16 P0.1A 453 0 - 1 - - - - - 1 453 P0.1B 4540 - - 1 1 1 1 1 5 2,270 P0.1C 4530 - 1 - - - - - 1 453 P0.1D 4530 - - 1 1 1 1 - 4 1,812 P0.2A 510
0 - - - - - - -
0 0 P0.3A 546
0 1 - - - - - - 1 546 P0.3B 5460 - 1 1 1 - - -
3 1,638 P0.3C 546
0 - - - - 1 - - 1 546 1 BEDROOM 28 P1.1A 698 68 - - 1 - - - - 1 698 P1.1B 700 68 - - - 1 1 1 1 4 2,800 P1.1C 701 68 - - - - 1 - - 1 701 P1.1D 698 68 - - - 1 1 1 1 4 2,792 P1.1E 701 68 - - - - - 1 1 2 1,402 P1.1F 690 61 - - - - - - - 0 0 P1.1G 701 66 - - - - - - -
0 0 P1.1H 698 66 - - - - - - -
0 0 P1.1J 690 61 - - - - - - -
0 0 P1.1K 698 66 - - - - - - -
0 0 P1.2A 741 39 - -
3 - - - -
3 2,223 P1.2B 741 37 - - -
3 3
3 3 12 8,892 P1.3A 723 84 1 - - - - - - 1 723 P1.3B 723 0 - - - - - - -
0 0 2 BEDROOM 32 P2.1B 1080 74 - 1 - 1 - - -
2 2,160 P2.1C 1080 74 - - 1 - 1 - -2 2,160 P2.1D 1083 84 1 - - - - - - 1 1,083 P2.1E 1083 74 - 1 - 1 - - -2 2,166 P2.1F 1083 74 - - 1 - 1 - -2 2,166 P2.1G 1081 68 - - - - 1 - - 1 1,081 P2.1H 1081 74 - - - - - 1 1 2 2,162 P2.1J 1079 68 - - - - - - -0 0 P2.1L 1063 70 - - - - - - -
0 0 P2.1P 1063 70 - - - - - - -
0 0 P2.1Q 1063
0 - - - - - - -
0 0 P2.2B 1154 77 - - 1 1 - 1 -
3 3,462 P2.2C 1154 77 - - - - 1 - - 1 1,154 P2.2D 1151 74 - - 1 1 - 1 -3 3,453 P2.2E 1151 74 - - - - 1 - 1 2 2,302 P2.2F 1143 77 - - - - - - 1 1 1,143 P2.2G 1150 67 - - - - - - -0 0 P2.2H 1150 67 - - - - - - -
0 0 P2.2J 1150 67 - - - - - - -
0 0 P2.2K 1150 67 - - - - - - -
0 0 P2.2L 1149 84 - - - - - - -
0 0 P2.2M 1149 84 - - - - - - -
0 0 P2.2N 1149 84 - - - - - - -
0 0 P2.2P 1152 63 - - - - - - -
0 0 P2.2Q 1152 63 - - - - - - -
0 0 P2.3A 998
0 - - - - - - -
0 0 P2.3B 998 47 - - - - - - -
0 0 P2.3C 998 47 - - - - - - -
0 0 P2.4A 932
0 - - 1 1 - 1 -
3 2,796 P2.4B 932
0 - - - - 1 - 1 2 1,864 P2.5A 1151 40 - - 1 - - - - 1 1,151 P2.5B 1151 37 - - - 1 1 1 1 4 4,604 P2.6A 11210 - - 1 1 1 1 - 4 4,484 3 BEDROOM
3 P3.1A 938 57 - - - - - - -
0 0 P3.1B 938 60 - - - - - - -
0 0 P3.1C 938 60 - - - - - - -
0 0 P3.2A 1059
0 1 - - - - - - 1 1,059 P3.2B 10550 - 1 - - - - - 1 1,055 P3.2C 10480 - - - - - - - 0 0 P3.4A 1053
0 1 - - - - - - 1 1,053 4 BEDROOM 16 P4.1A 1325 60 1 - - - - - - 1 1,325 P4.1B 1325 49 - 1 - 1 - - - 2 2,650 P4.1C 1320 49 - - 1 - 1 - -2 2,640 P4.1E 1288 44 - - - - - - 1 1 1,288 P4.1F 1300 0 - 1 - - - - - 1 1,300 P4.1G 12900 - - 1 - - - - 1 1,290 P4.1H 1290 44 - - - 1 1 1 1 4 5,160 P4.1J 12930 - - 1 - - - - 1 1,293 P4.1K 1293 44 - - - 1 1 1 - 3 3,879 P4.1L 1296 60 - - - - - - -0
0 P4.1M 1296 63 - - - - - - -
0 0 P4.1N 1296 47 - - - - - - -
0 0 P4.1P 1296 63 - - - - - - -
0 0 P4.1Q 1296 47 - - - - - - -
0 0 P4.2A 1494 87 - - - - - - -
0 0 P4.2B 1494 87 - - - - - - -
0 0 TOTALS
6 8 17 18 20 16 14 99 91,332
City Council 23 – 1812/6/2022
LV ELEC
LV ELEC
LV
ELEC
LV
ELEC UP UP UP UP UP TURN-AROUND SPOT TRASH / LOADING
VAN BIKE FIRE PUMP ROOM BOOSTER PUMP ROOM STAIR A1 STAIR A2 TURN AROUND SPOT VAN VAN UP 5%UP 5% UP 2%
UP 5%
EV EV EV DN 4.5%
FEC
FEC FEC
ñ
ñ
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ PARCEL ROOM LV
ELEC UP
DN 2.2% UP UP UP TV
TRASH RECY REF SP SP
W R F
FEC
FEC
FEC
ELEC 77' 150'
135' 150'
*
* F.E.C.
F.E.C.
113'
139' 150' BUILDING A FIRST FLOOR FIRE PROTECTION PLANS BUILDING A - LEVEL 1 FIRE PROTECTION PLAN SCALE: 3/32"=1'-0" 1 A0-11 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 1912/6/2022
LV ELEC
LV ELEC
LV
ELEC
LV
ELEC
LV
ELEC LV ELEC
ELEC
ELEC
VAN OPEN TO BELOW STAIR A1 UP 5%
UP 5% UP 5%
UP 4.3% DOWN 5%
EV EV EV EV EV EV EV UP DN UP
FEC
FEC FECFEC
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ
G R W DN UP DNUP DN UP
SHELVING
SPSP
FEC
FEC
FEC 84' 150'
135' 150'
*
*
F.E.C.
F.E.C. 140' 150' COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A SECOND FLOOR FIRE PROTECTION PLANS BUILDING A - LEVEL 2 FIRE PROTECTION PLAN SCALE: 3/32"=1'-0" 1 A0-12 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 2012/6/2022 E E
D
D
D
E
G R W SP SP
LV ELEC
LV
ELEC
LV
ELEC
LV ELEC
LV ELEC LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC UPDN UP STAIR A1 UP 5%
UP 5.0% UP 5% DOWN 5% EV
EV EV EV
FEC
EV
FEC FEC FEC
DOWN 1.5%
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ STAIR A4 STAIR A3 STAIR A2 UP DN DNUP ELECTRICAL METERS ABOVE DN UP (2)WARMING D/W ICE REF U/C MICRO DRAWERS TRASHRECY FEC
FEC FEC
FEC 2% MIN. 9% MIN. 2% MIN. 2% MIN. 2% MIN. 4% MIN. 3.5% MIN. 3.5% MIN. 9% MIN. 9% MIN. 11% MIN. 3% MIN. 7% MIN. 3% MIN. 4.6% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3% MIN. 3% MIN. 4% MIN. 4% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 4% MIN. 4% MIN. 3% MIN. 3% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 5% MIN. 5% MIN. 3% MIN. 3% MIN. 3% MIN. 3% MIN. 5% MIN. 5% MIN. 4% MIN. 4% MIN. 3% MIN. 3% MIN. 3% MIN. 5% MIN. 5% MIN. 5% MIN. 5% MIN. 7% MIN. 7% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3% MIN. 3% MIN. 3% MIN. 3% MIN. 2% MIN. 4% MIN. 7% MIN. 2% MIN. DN DOWN 3.1% CLUBROOM MENS RESTROOM WOMENS RESTROOM POOL SHOWER 150' 150' 150'
135' 150' 150'
*
*
F.E.C.
F.E.C. 150' HOSE PULL IF ROUTED OVER POOL ENCLOSURE FENCE 112' 68' COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A THIRD FLOOR FIRE PROTECTION PLANS BUILDING A - LEVEL 3 FIRE PROTECTION PLANS SCALE: 3/32"=1'-0" 1 A0-13 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 2112/6/2022
G R W SP SP
LV ELEC
LV
ELEC
LV
ELEC
LV ELEC
LV ELEC LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC DN UP STAIR A1 UP 5%
UP 5% UP 5% DOWN 5%
FEC FEC FEC FEC
DOWM 1.5%
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ LV
ELEC STAIR A4 STAIR A3 STAIR A2 UP DN DNUP DN UP HVAC SP FEC
FEC FEC
FEC DN
3.1% 150' 150'
135' 150' 150'
*
*
F.E.C. F.E.C. COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A FOURTH FLOOR FIRE PROTECTION PLANS BUILDING A - LEVEL 4 FIRE PROTECTION PLANS SCALE: 3/32"=1'-0" 1 A0-14 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 2212/6/2022
G R W SP SP
LV ELEC
LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC TURN- AROUND SPOT
UP 5% UP 5% DOWN 5%
FEC
DOWN 1.6%
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ STAIR A4 STAIR A3 LV ELEC UP DN DN DNUP ELECTRICAL METERS
LV ELEC
LV
ELEC
LV
ELEC
FEC
FEC FEC DN
DOWN 4.5%
FEC150' 150'
135' 135' 150'
*
*
F.E.C. COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A FIFTH FLOOR FIRE PROTECTION PLANS BUILDING A - LEVEL 5 FIRE PROTECTION PLANS SCALE: 3/32"=1'-0" 1 A0-15 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 2312/6/2022
G R W SP SP
LV ELEC
LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC STAIR A4 STAIR A3 TURN- AROUND SPOT
UP 5% UP 5% DOWN 5%
FEC
DOWN 1.6%
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ UP DN DNUP
FEC FEC FEC STORAGE 150' 150'
*
* COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A SIXTH FLOOR FIRE PROTECTION PLANS BUILDING A - LEVEL 6 FIRE PROTECTION PLANS SCALE: 3/32"=1'-0" 1 A0-16 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 2412/6/2022
G R W SP SP
LV ELEC
ELEC
LV LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC STAIR A4 STAIR A3 LV ELEC LV ELEC
LV
ELEC DN DN ELEVATOR MACHINE ROOM
LV ELEC SP
FEC FEC FEC 150' 150'
*
* COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A SEVENTH FLOOR FIRE PROTECTION PLANS BUILDING A - LEVEL 7 FIRE PROTECTION PLANS SCALE: 3/32"=1'-0" 1 A0-17 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 2512/6/2022
FEC SP SP FEC FEC
FEC LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
ELEC LV LV
ELEC LV
ELEC
LV ELEC
LV
ELEC UP UP UP UP UP
R
W TRASH / LOADING UP 5%
UP 5% BIKE STORAGE ROOM FIRE PUMP ROOM BOOSTER PUMP ROOM VAN UP 5% UP 6.2% UP 2%
G MAILROOM PARCEL
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC
FEC TRASH VESTIBULE ELECTRICAL ROOM STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 LV ELEC MPOE IDF UP DN 6.5% UP DN UP UP DN 2% UP
G
G
DN 8%
DN 4.67%
ELEC UP DN 4.67% DN 4.67%
DN 4.67% STORAGE 150' 150'
*
* 150' 150' 150'
F.E.C. F.E.C.
F.E.C. COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B FIRST FLOOR FIRE PROTECTION PLAN BUILDING B - LEVEL 1 FIRE PROTECTION PLAN SCALE: 3/32"=1'-0" 1 A0-21 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 2612/6/2022
FEC SP SP FEC FEC
FEC LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
ELEC LV LV
ELEC
LV ELEC
R W G UP 5% RAMP UP 93' (RUN) (5% SLOPE) = 4.65' (RISE) UP 3.5% DN 5% OPEN TO BELOW VAN
UP 5% UP DN UP EV EV EV EV
EV
EV EV EV
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC
FEC FEC LV ELEC LV ELEC
LV ELEC STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 IDF UPDN LV
ELEC UP UP DN DNUP TRASH VESTIBULE 150'
*
* 150' 150' 150'
150'
F.E.C. F.E.C.
F.E.C. COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B SECOND FLOOR FIRE PROTECTION PLAN BUILDING B - LEVEL 2 FIRE PROTECTION PLAN SCALE: 3/32"=1'-0" 1 A0-22 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 2712/6/2022
FEC SP SP FEC FEC
FEC LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
LV
ELEC
ELEC LV LV
ELEC
LV ELEC
R W G UP 5% UP 5%
UP 3.5% DN 5% UP DN UP EV EV EV
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC
FEC FEC LV ELEC LV ELEC
LV ELEC STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 UPDN IDF DNUP UP UP DN TRASH VESTIBULE 150' 150' *
* 150' 150'150'
F.E.C. F.E.C.
F.E.C. F.E.C. COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B THIRD FLOOR FIRE PROTECTION PLAN BUILDING B - LEVEL 3 FIRE PROTECTION PLAN SCALE: 3/32"=1'-0" 1 A0-23 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 2812/6/2022
FEC SP SP FEC FEC
FEC LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
LV
ELEC
ELEC LV LV
ELEC
LV ELEC LV ELEC LV ELEC
LV ELEC STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 UPDN IDF DNUP UP UP DN R W G RAMP UP 93' (RUN) (5% SLOPE) = 4.65' (RISE)
UP 3.5% DN 5% UP 5% DN UP
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC TRASH VESTIBULE 150' 150'
*
* 150' 150'150'
F.E.C. F.E.C. COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B FOURTH FLOOR FIRE PROTECTION PLAN BUILDING B - LEVEL 4 FIRE PROTECTION PLAN SCALE: 3/32"=1'-0" 1 A0-24 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 2912/6/2022
FEC SP SP FEC FEC
FEC LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
LV
ELEC
ELEC LV LV
ELEC
LV ELEC LV ELEC LV ELEC
LV ELEC
R W G STAIR B1 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 DN ELEVATOR MACHINE ROOM DN DN TRASH VESTIBULE ROOF ACCESS *
* 150' 150'150' COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B FIFTH FLOOR FIRE PROTECTION PLAN BUILDING B - LEVEL 5 FIRE PROTECTION PLAN SCALE: 3/32"=1'-0" 1 A0-25 DESCRIPTION TYPE III-A ASSEMBLIES FLOOR / CEILING - FRAMED TYP. INTERIOR INTERIOR NON-STACKING SHAFT INTERIOR CORRIDOR EXTERIOR CORRIDOR PRIVATE BALCONY FIRE RATING DETAIL REFERENCE(S) 1 HR 2 HR 1 HR 1 HR 0 HR 1/AD-21 X/AD-XX 3/AD-21 2/AD-21 4/AD-21 FIRE BARRIERS SHAFT ENCLOSURE GREASE SHAFT ENCLOSURE OCCUPANCY SEPARATION (R-2/A-3/B) & TRASH ACCESS ROOM 2 HR 3 HR 1 HR 20/AD-22.1, 8/AD-24 15/AD-26 X/AD-XX, X/AD-XX FIRE PARTITIONS CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 12/AD-24, 20/AD-24 4/AD-24 NONBEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 9/AD-24 1/AD-22 SIM. 8/AD-22 BEARING WALLS EXTERIOR (TYPE III-A) INTERIOR 2 HR 1 HR 14/AD-24 1/AD-22 FIRE WALLS 3 HOUR 3 HR 1/AD-25 PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. STEEL BEAM TYP. WOOD COLUMN TYP. WOOD BEAM 2 HR 2 HR 2 HR 2 HR 16/AD-28 12/AD-28 4/AD-28 4/AD-28 LEGEND DESCRIPTION TYPE I-A ASSEMBLIES FLOOR / CEILING - CONCRETE SLAB CONCRETE SLAB ON GRADE FLOOR / CEILING - 2ND LEVEL SLAB SUSPENDED CONCRETE SLAB FLOOR / CEILING - CONCRETE PODIUM SLAB TYP. INTERIOR TYP. EXTERIOR @ COURTYARD TYP. EXTERIOR @ PRIVATE DECKS TYP. EXTERIOR SHELF (NON-OCCUPIABLE SPACE) FIRE RATING DETAIL REFERENCE(S) 0 HR X/AD-XX FIRE BARRIER SHAFT ENCLOSURE (SINGLE WALL) SHAFT ENCLOSURE (DOUBLE WALL) SHAFT WALL (NON-LOAD BEARING) TRASH ACCESS ROOM 2 HR 2 HR 2 HR 1 HR 13/AD-22 15/AD-22 14/AD-22 9/AD-22, X/AD-XX FIRE PARTITION CORRIDOR TO UNIT UNIT TO UNIT 1 HR 1 HR 10/AD-22 11/AD-22 NON-BEARING WALLS & PARTITIONS EXTERIOR PARTITION OR FURRING INTERIOR PARTITION OR FURRING INTERIOR PLUMBING 0 HR 0 HR 0 HR 3/AD-24, 7/AD-24 9/AD-22 SIM. 12/AD-22 BEARING WALLS EXTERIOR INTERIOR 3 HR 3 HR X/AD-XX X/AD-XX PRIMARY STRUCTURAL FRAME - (SEE STRL FOR LOCATIONS) TYP. STEEL COLUMN TYP. CONCRETE COLUMN 3 HR 3 HR X/AD-XX X/AD-XX SYMBOL LEGEND (1 SHORT DASH) (2 SHORT DASHES) (DASHED LINE) SYMBOL LEGEND 3 HR 3 HR 3 HR 3 HR 21/AD-21 X/AD-XX X/AD-XX X/AD-XX 2 HR 13/AD-21 BUILDING ENTRANCE 150' HOSE PULL STANDPIPE IN INTERIOR EXIT STAIRWAY XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *F.E.C. FIRE EXTINGUISHER CABINET - SURFACE MOUNTED. PAINT CAB TO MATCH ADJACENT WALL FINISH. F.E.C. FIRE EXTINGUISHER CABINET - SEMI-RECESSED. PAINT CAB TO MATCH ADJACENT WALL FINISH. 1. REFER TO FIRE MASTER PLAN FOR ADDITIONAL INFORMATION. 2. NON-SEPARATED OCCUPANCIES OCCUR IN TYPE IA PER CBC SECTION 508.3 3. REFER TO ENLARGED UNIT PLANS FOR BATHROOM AND KITCHEN EXHAUST RATED SHAFT DETAILS. 4. REFER TO SHEET AD-20.1 FOR ALL FIRE-RESISTANCE RATED PENETRATIONS DETAILS. FIRE PROTECTION NOTES PARTIAL SECTION City Council 23 – 3012/6/2022
LV ELEC
LV ELEC
LV
ELEC
LV
ELEC UP UP UP UP UP TURN-AROUND SPOT TRASH / LOADING
VAN BIKE FIRE PUMP ROOM BOOSTER PUMP ROOM STAIR A1 STAIR A2 TURN AROUND SPOT VAN VAN UP 5%UP 5% UP 2%
UP 5%
EV EV EV DN 4.5%
FEC
FEC FEC
ñ
ñ
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ PARCEL ROOM LV
ELEC UP
DN 2.2% UP UP UP TV
TRASH RECY REF SP SP
W R F
FEC
FEC
FEC
ELEC TRASH 2446 300
9 S-2 DWELLING UNIT 1003 200
6 R-2 DWELLING UNIT 1256 200
7 R-2 DWELLING UNIT 690 200
4 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 1286 200
7 R-2 DWELLING UNIT 482 200
3 R-2 ELECTRICAL RM 338 300
2 R-2 CO-WORKING 2612 15 175 A-3 WORK POD 80 150
1 A-3 RETAIL 8103 60 RESTAURANT 135
M 2573 15 172 A-3 KITCHEN 1437 200
8 M TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 470.2 8.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 420.3 REQUIRED STAIR WIDTH 12.6" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 42 EXIT 42 PARKING 17602 200 89 S-2 TOTAL PARKING OCCUPANT LOAD = 92 92 OCCUPANTS/3 EXITS =30/31 OCC. PER EXIT EXIT 30 EXIT 31 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 300.2 6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 420.2 8.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 450.2 9" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" CPET = 51'-4" L = 176'-9" CPET = 21'-6"L = 121'-5" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 310.2 6.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 310.3 REQUIRED STAIR WIDTH 9.3" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 45 EXIT 31 BIKE STORAGE 437 300 2 S-2 BOOSTER PUMP 165 300
1 S-2 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 830.2 16.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 310.2 6.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" TOTAL OCCUPANT LOAD = 91 91 OCCUPANTS/2 EXITS =45/46 OCC. PER EXIT TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 460.2 9.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 72" EXIT 46 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 430.2 8.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" EXIT 43 EXIT DISCHARGE 83 ABV
83 FRM
EXIT
DISCHARGE
EXIT
DISCHARGE
EXIT DISCHARGE EXIT DISCHARGE
EXIT
DISCHARGE
223 223 FRM ABV EXIT DISCHARGE112 112 FRM ABV EXIT DISCHARGE TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 112 0.2 22.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" EXIT DISCHARGE TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 223 0.2 44.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 48" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 540.2 10.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" EXIT DISCHARGE 54 ABV
54 FRM 181'-1 233/256" 1/3 OVERALL DIMENSION =106'-0"
OVERALL DIAGONAL DIMENSION = 317'-11" 1/3 OVERALL DIMENSION = 106'-0" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 OVERALL DIAGONAL DIMENSION = 204'-6" 1/3 OVERALL DIMENSION = 68'-2" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 161'-10" 1/3 OVERALL DIMENSION =68'-2" OVERALL DIAGONAL DIMENSION = 125'-1 41/128" 1/3 OVERALL DIMENSION = 41'-8" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 51'-6" 1/3 OVERALL DIMENSION =41'-8" FITNESS 1553 50 32 A-3 CPET = 62'-1" EXIT 86 OVERALL DIAGONAL DIMENSION = 82'-9 243/256" 1/3 OVERALL DIMENSION = 27'-7" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 34'-8 51/256" 1/3 OVERALL DIMENSION =27'-7" EXIT 67 EXIT 68 FIRE WALL WORK POD 80 150 1 A-3 WORK POD 78 150
1 A-3 CONFERENCE 244 15 17 A-3 OFFICE 145 150
1 A-3 OFFICE 160 150
2 A-3 TOTAL LEASING/CO-WORKING OCCUPANT LOAD = 198 198 OCCUPANTS/3 EXITS =66 OCC. PER EXIT EXIT DISCHARGE EXIT 66 66 66 TRASH 101 300 1 R-2 MPOE 86 300
1 R-2 EXIT 86 TOTAL OCCUPANT LOAD = 127 127 OCCUPANTS/3 EXITS =42/43 OCC. PER EXIT L = 135'-1" CPET = 58'-7" OVERALL DIAGONAL DIMENSION = 111'-0" 1/3 OVERALL DIMENSION = 37'-0" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 103'-9" 1/3 OVERALL DIMENSION =37'-0" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 860.2 17.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 680.2 13.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" CPET = 30'-0" L =122'-0" CPET = 52'-0" L =83'-8" COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A FIRST FLOOR EXITING ANALYSIS BUILDING A - LEVEL 1 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 A0-31 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 City Council 23 – 3112/6/2022
LV ELEC
LV ELEC
LV
ELEC
LV
ELEC
LV
ELEC LV ELEC
ELEC
ELEC
VAN OPEN TO BELOW STAIR A1 UP 5%
UP 5% UP 5%
UP 4.3% DOWN 5%
EV EV EV EV EV EV EV UP DN UP
FEC
FEC FECFEC
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ
G R W DN UP DNUP DN UP
SHELVING
SPSP
FEC
FEC
FEC DWELLING UNIT 424 200
3 R-2 TRASH 81 300
1 R-2 DWELLING UNIT 1014 200
6 R-2 DWELLING UNIT 1251 200
7 R-2 DWELLING UNIT 424 200
3 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 1286 200
7 R-2 DWELLING UNIT 482 200
3 R-2 TOTAL INTERIOR OCCUPANT LOAD = 146 146 OCCUPANTS/3 EXITS =48/49 OCC. PER EXIT TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 490.2 9.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 490.3 REQUIRED STAIR WIDTH 14.7" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 49 EXIT 49 PARKING 19767 200 99 S-2 TOTAL PARKING OCCUPANT LOAD = 99 99 OCCUPANTS/2 EXITS =49/50 OCC. PER EXIT EXIT 49 TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 490.3 REQUIRED STAIR WIDTH 14.7" PROPOSED STAIR WIDTH 48" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 490.2 9.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 480.2 9.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 480.3 REQUIRED STAIR WIDTH 14.4" PROPOSED STAIR WIDTH 75" MIN. 33.4" 36" CPET = 55'-8" L = 137'-8" CPET = 21'-6" L = 135'-1" CPET = 58'-7" L = 130'-2" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 490.2 9.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 490.3 REQUIRED STAIR WIDTH 14.7" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" RESIDENT STORAGE 2144 200 11 R-2 POOL EQUIP RM 383 300 2 R-2 YOGA 523 50 11 A-3 EXIT 48 50 FIRE WALL HORIZONTAL EXIT AT FIRE WALL PROVIDED FOR ACCESSIBLE MEANS OF EGRESS ONLY PER CBC 1009.2.1 EXCEPTION 1 176'-11 101/256" 1/3 OVERALL DIMENSION =111'-0" OVERALL DIAGONAL DIMENSION = 333'-0" 1/3 OVERALL DIMENSION = 111'-0" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 OVERALL DIAGONAL DIMENSION = 204'-6" 1/3 OVERALL DIMENSION = 68'-2" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 206'-7" 1/3 OVERALL DIMENSION =68'-2" RESIDENT STORAGE 957 200 5 R-2 RETAIL STORAGE 409 200
3 R-2 MAINTENANCE 212 300
1 R-2 SHARED GOODS 418 200
3 R-2 BREAK ROOM 185 15 12 R-2 OPERATIONS 634 150
5 R-2 STORAGE 108 200
1 R-2 L = 194'-9" CPET = 96'-4" L = 177'-9" CPET = 56'-3" COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A SECOND FLOOR EXITING ANALYSIS A0-32 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 BUILDING A - LEVEL 2 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 City Council 23 – 3212/6/2022 E E
D
D
D
E
G R W SP SP
LV ELEC
LV
ELEC
LV
ELEC
LV ELEC
LV ELEC LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC UPDN UP STAIR A1 UP 5%
UP 5.0% UP 5% DOWN 5% EV
EV EV EV
FEC
EV
FEC FEC FEC
DOWN 1.5%
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ UP DN DNUP DN UP (2)WARMING D/W ICE REF U/C MICRO DRAWERS TRASHRECY FEC
FEC FEC
FEC 2% MIN. 9% MIN. 2% MIN. 2% MIN. 2% MIN. 4% MIN. 3.5% MIN. 3.5% MIN. 9% MIN. 9% MIN. 11% MIN. 3% MIN. 7% MIN. 3% MIN. 4.6% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3% MIN. 3% MIN. 4% MIN. 4% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 4% MIN. 4% MIN. 3% MIN. 3% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 5% MIN. 5% MIN. 3% MIN. 3% MIN. 3% MIN. 3% MIN. 5% MIN. 5% MIN. 4% MIN. 4% MIN. 3% MIN. 3% MIN. 3% MIN. 5% MIN. 5% MIN. 5% MIN. 5% MIN. 7% MIN. 7% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3% MIN. 3% MIN. 3% MIN. 3% MIN. 2% MIN. 4% MIN. 7% MIN. 2% MIN. DWELLING UNIT 424 200 3 R-2 POOL 1115 50 23 A-3 SPA 162 50
4 A-3 POOL DECK 2822 15 189 A-3 COURTYARD 337 15 23 A-3 TOTAL POOL ENCLOSURE OCCUPANT LOAD = 216 216 OCCUPANTS/2 EXITS =108 OCC. PER EXIT TRASH 81 300 1 R-2 DWELLING UNIT 1251 200
7 R-2 DWELLING UNIT 1121 200
6 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 1107 200
6 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 907 200
5 R-2 DWELLING UNIT 1251 200
7 R-2 DWELLING UNIT 424 200
3 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 1286 200
7 R-2 DWELLING UNIT 482 200
3 R-2 TOTAL INTERIOR OCCUPANT LOAD PORTION 1 = 314 314 OCCUPANTS/3 EXITS =104/105 OCC. PER EXIT 108 108 TOTAL OUTDOOR OCCUPANT LOAD = 239 239 OCCUPANTS/2 EXITS =119/120 OCC. PER EXIT 120 62 62 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 104 0.2 20.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36"EXIT 104 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 105 0.2 21" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 105 0.3 REQUIRED STAIR WIDTH 31.5" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 105 STAIR A3 STAIR A4 EXIT 16 PARKING 21217 200 107 R-2 TOTAL PARKING OCCUPANT LOAD = 107 107 OCCUPANTS/2 EXITS =53/54 OCC. PER EXIT EXIT 53 EXIT 54 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 530.2 10.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 690.3 REQUIRED STAIR WIDTH 20.7" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 160.2 23.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" EXIT 119 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 223 0.2 44.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 223 0.3 REQUIRED STAIR WIDTH 66.9" PROPOSED STAIR WIDTH 68" MIN. 33.4" 48" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 119 0.2 23.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" L = 141'-4" CPET = 63'-7" L = 206'-0" CPET = 55'-8" 12'-10" 18'-2 1/2" DEAD END CORRIDOR MAX. = 50' CPET = 77'-5" CPET = 54'-5" L = 176'-9" CPET = 21'-6" L = 94'-7" CPET = 94'-7" L = 130'-2" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 540.2 10.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 540.3 REQUIRED STAIR WIDTH 16.2" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" OVERALL DIAGONAL DIMENSION = 90'-0 135/256" 1/3 OVERALL DIMENSION = 30'-0" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 FIRE WALL FIRE WALL 170'-6 19/64" 1/3 OVERALL DIMENSION =93'-5" OVERALL DIAGONAL DIMENSION = 280'-2" 1/3 OVERALL DIMENSION = 93'-5" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 OVERALL DIAGONAL DIMENSION = 204'-6" 1/3 OVERALL DIMENSION = 68'-2" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 161'-10" 1/3 OVERALL DIMENSION =68'-2" 1/3 OVERALL DIMENSION =30'-0" 42'-5 141/256" L = 185'-11" CLUBROOM 1816 15 122 A-3 OVERALL DIAGONAL DIMENSION = 66'-11 99/256" 1/3 OVERALL DIMENSION = 22'-4" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 42'-3 237/256" 1/3 OVERALL DIMENSION =22'-4" HORIZONTAL EXIT HORIZONTAL EXIT PER CBC SECTION 1026 AND CBC SECTION 1026.2 1. PROVIDE STANDPIPE AS REQUIRED PER CBC SECTION 905 AND PER CFC SECTION 905.4 #2. 2. REFUGE AREA OF THE HORIZONTAL EXIT PER CBC SEC. 1026.4 112 occupants entering the horizontal exit require 336 sq. ft of refuge + 48 sq ft for tenants residing in that zone =493 sq. ft of refuge area provided TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 105 0.2 21" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" EXIT 105 TOTAL INTERIOR OCCUPANT LOAD PORTION 2 = 16 16 OCCUPANTS/1 EXITS =16 OCC. PER EXIT OVERALL DIAGONAL DIMENSION = 94'-11 227/256" 1/3 OVERALL DIMENSION = 31'-8" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 46'-4 173/256" 1/3 OVERALL DIMENSION =31'-8" STANDPIPE NOT REQUIRED AT THIS LOCATION PER CBC 905.4 #2 EXCEPTION. HORIZONTAL EXIT IS LOCATED 83'-5" FROM INTERIOR EXIT STAIR HOSE CONNECTION. COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A THIRD FLOOR EXITING ANALYSIS A0-33 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 BUILDING A - LEVEL 3 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 City Council 23 – 3312/6/2022
G R W SP SP
LV ELEC
LV
ELEC
LV
ELEC
LV ELEC
LV ELEC LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC DN UP STAIR A1 UP 5%
UP 5% UP 5% DOWN 5%
FEC FEC FEC FEC
DOWM 1.5%
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ LV
ELEC STAIR A4 STAIR A3 STAIR A2 UP DN DNUP DN UP HVAC SP FEC
FEC FEC
FEC DN
3.1% DWELLING UNIT 1126 200
6 R-2 DWELLING UNIT 1126 200
6 R-2 DWELLING UNIT 1250 200
7 R-2 DWELLING UNIT 1107 200
6 R-2 DWELLING UNIT 705 200
4 R-2 TRASH 81 300
1 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 424 200
3 R-2 DWELLING UNIT 1251 200
7 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 909 200
5 R-2
FIRE WALL HORIZONTAL EXIT AT FIRE WALL PROVIDED FOR ACCESSIBLE MEANS OF EGRESS ONLY PER CBC 1009.2.1 EXCEPTION 1 EXIT 31 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 300.2 6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 300.3 REQUIRED STAIR WIDTH 9" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" TOTAL OCCUPANT LOAD = 91 128 OCCUPANTS/3 EXITS =30/31 OCC. PER EXIT EXIT 30 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 310.2 6.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 310.3 REQUIRED STAIR WIDTH 9.3" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" L = 141'-4" CPET = 63'-7" L = 180'-2" CPET = 55'-8" 12'-10" 18'-2 1/2" DEAD END CORRIDOR MAX. = 50' CPET = 77'-5" CPET = 54'-5" DWELLING UNIT 424 200 3 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 1286 200
7 R-2 DWELLING UNIT 490 200
3 R-2 EXIT 30 EXIT 53 DWELLING UNIT 1126 200
6 R-2 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 530.2 10.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 830.3 REQUIRED STAIR WIDTH 24.9" PROPOSED STAIR WIDTH 66" MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 300.2 6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" L = 176'-9" CPET = 21'-6" L = 135'-1" CPET = 58'-7" PARKING 21217 200 107 R-2 TOTAL PARKING OCCUPANT LOAD = 107 107 OCCUPANTS/2 EXITS =53/54 OCC. PER EXIT EXIT 54 L = 130'-2" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 540.2 10.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 540.3 REQUIRED STAIR WIDTH 16.2" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" FIRE WALL 170'-6 19/64" 1/3 OVERALL DIMENSION =111'-0" OVERALL DIAGONAL DIMENSION = 333'-0" 1/3 OVERALL DIMENSION = 111'-0" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 OVERALL DIAGONAL DIMENSION = 204'-6" 1/3 OVERALL DIMENSION = 68'-2" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 161'-10" 1/3 OVERALL DIMENSION =68'-2" COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A FOURTH FLOOR EXITING ANALYSIS A0-34 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 BUILDING A - LEVEL 4 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 City Council 23 – 3412/6/2022
G R W SP SP
LV ELEC
LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC TURN- AROUND SPOT
UP 5% UP 5% DOWN 5%
FEC
DOWN 1.6%
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ STAIR A4 STAIR A3 LV ELEC UP DN DN DNUP ELECTRICAL METERS
LV ELEC
LV
ELEC
LV
ELEC
FEC
FEC FEC DN
DOWN 4.5%
FEC DWELLING UNIT 1126 200
6 R-2 DWELLING UNIT 1126 200
6 R-2 DWELLING UNIT 1250 200
7 R-2 DWELLING UNIT 1107 200
6 R-2 DWELLING UNIT 705 200
4 R-2 TRASH 81 300
1 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 424 200
3 R-2 DWELLING UNIT 1251 200
7 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 909 200
5 R-2
FIRE WALL HORIZONTAL EXIT AT FIRE WALL PROVIDED FOR ACCESSIBLE MEANS OF EGRESS ONLY PER CBC 1009.2.1 EXCEPTION 1 EXIT 43 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 420.2 8.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 420.3 REQUIRED STAIR WIDTH 12.6" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" TOTAL OCCUPANT LOAD = 128 128 OCCUPANTS/3 EXITS =42/43 OCC. PER EXIT EXIT 42 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 430.2 8.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 430.3 REQUIRED STAIR WIDTH 12.9" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" 170'-6 19/64" 1/3 OVERALL DIMENSION =111'-0" L = 218'-1" CPET = 63'-7" CPET = 58'-3" L = 180'-2" CPET = 55'-8" 12'-10" 18'-2 1/2" DEAD END CORRIDOR MAX. = 50' CPET = 77'-5" CPET = 54'-5" DWELLING UNIT 424 200 3 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 1286 200
7 R-2 DWELLING UNIT 490 200
3 R-2 EXIT 43 PARKING 10476 200 53 S-2 TOTAL PARKING OCCUPANT LOAD = 53 53 OCCUPANTS/2 EXITS =26/27 OCC. PER EXIT EXIT 26 AREA DOWN RAMP IS INCLUDED AS PART OF LEVEL BELOW DWELLING UNIT 1126 200 6 R-2 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 260.2 5.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 690.3 REQUIRED STAIR WIDTH 20.7" PROPOSED STAIR WIDTH 66" MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 430.2 8.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" L = 176'-9" 27 CPET = 84'-4" L = 135'-1" CPET = 58'-7" FIRE WALL OVERALL DIAGONAL DIMENSION = 333'-0" 1/3 OVERALL DIMENSION = 111'-0" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 OVERALL DIAGONAL DIMENSION = 149'-0" 1/3 OVERALL DIMENSION = 49'-8" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 92'-6 5/8" 1/3 OVERALL DIMENSION =49'-8" COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A FIFTH FLOOR EXITING ANALYSIS A0-35 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 BUILDING A - LEVEL 5 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 City Council 23 – 3512/6/2022
G R W SP SP
LV ELEC
LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC TURN- AROUND SPOT
UP 5% UP 5% DOWN 5%
FEC
DOWN 1.6%
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ UP DN DNUP
FEC FEC FEC DWELLING UNIT 1126 200
6 R-2 DWELLING UNIT 1126 200
6 R-2 DWELLING UNIT 1250 200
7 R-2 DWELLING UNIT 1107 200
6 R-2 DWELLING UNIT 705 200
4 R-2 TRASH 81 300
1 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 424 200
3 R-2 DWELLING UNIT 1251 200
7 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 909 200
5 R-2 ACCESSORY 58 300
1 R-2
FIRE WALL HORIZONTAL EXIT AT FIRE WALL PROVIDED FOR ACCESSIBLE MEANS OF EGRESS ONLY PER CBC 1009.2.1 EXCEPTION 1 EXIT 41 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 400.2 8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 620.3 REQUIRED STAIR WIDTH 12" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" TOTAL OCCUPANT LOAD = 81 81 OCCUPANTS/2 EXITS =40/41 OCC. PER EXIT EXIT 40 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 410.2 8.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 410.3 REQUIRED STAIR WIDTH 12.3" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" OVERALL DIAGONAL DIMENSION = 268'-0" 1/3 OVERALL DIMENSION = 89'-4" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 170'-6 19/64" 1/3 OVERALL DIMENSION = 89'-4" L = 218'-1" CPET = 63'-7" CPET = 58'-3" L = 180'-2" CPET = 55'-8" 12'-10" 18'-2 1/2" DEAD END CORRIDOR MAX. = 50' CPET = 77'-5" CPET = 54'-5" DWELLING UNIT 424 200 3 R-2 DWELLING UNIT 1126 200
6 R-2 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A SIXTH FLOOR EXITING ANALYSIS A0-36 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 BUILDING A - LEVEL 6 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 City Council 23 – 3612/6/2022
G R W SP SP
LV ELEC
ELEC
LV LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC LV ELEC LV ELEC
LV
ELEC DN DN
LV ELEC SP
FEC FEC FEC DWELLING UNIT 1126 200
6 R-2 ROOF DECK 735 15 49
B DWELLING UNIT 1126 200
6 R-2 DWELLING UNIT 1250 200
7 R-2 DWELLING UNIT 1107 200
6 R-2 DWELLING UNIT 705 200
4 R-2 TRASH 81 300
1 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 705 200
4 R-2 DWELLING UNIT 424 200
3 R-2 DWELLING UNIT 1251 200
7 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 909 200
5 R-2 ACCESSORY 58 300
1 R-2
FIRE WALL HORIZONTAL EXIT AT FIRE WALL PROVIDED FOR ACCESSIBLE MEANS OF EGRESS ONLY PER CBC 1009.2.1 EXCEPTION 1 EXIT 61 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 600.2 12" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 600.3 REQUIRED STAIR WIDTH 18" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" TOTAL OCCUPANT LOAD = 121 121 OCCUPANTS/2 EXITS =60/61 OCC. PER EXIT EXIT 60 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 610.2 12.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 610.3 REQUIRED STAIR WIDTH 18.3" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" OVERALL DIAGONAL DIMENSION = 268'-0" 1/3 OVERALL DIMENSION = 89'-4" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 170'-6 19/64" 1/3 OVERALL DIMENSION = 89'-4" L = 218'-1" CPET = 63'-7" CPET = 79'-7" CPET = 58'-3" L = 180'-2" CPET = 55'-8" 12'-10" 18'-2 1/2" DEAD END CORRIDOR MAX. = 50' CPET = 77'-5" CPET = 54'-5" COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A SEVENTH FLOOR EXITING ANALYSIS A0-37 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 BUILDING A - LEVEL 7 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 City Council 23 – 3712/6/2022
CORRIDOR VENTILATION SHAFT CORRIDOR VENTILATION SHAFT CORRIDOR VENTILATION SHAFT FEC SP SP FEC FEC
FEC LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
ELEC LV LV
ELEC LV
ELEC
LV ELEC
LV
ELEC UP UP UP UP UP
R
W TRASH / LOADING UP 5%
UP 5% BIKE STORAGE ROOM FIRE PUMP ROOM BOOSTER PUMP ROOM VAN UP 5% UP 6.2% UP 2%
G MAILROOM PARCEL
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC
FEC TRASH VESTIBULE ELECTRICAL ROOM STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 LV ELEC MPOE IDF UP DN 6.5% UP DN UP UP DN 2% UP
G
G
DN 8%
DN 4.67%
ELEC UP DN 4.67% DN 4.67%
DN 4.67% STORAGE DWELLING UNIT 485 200
3 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 690 200
4 R-2 DWELLING UNIT 1262 200
7 R-2 DWELLING UNIT 908 200
5 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 1436 200
8 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 1436 200
8 R-2 DWELLING UNIT 1015 200
6 R-2 DWELLING UNIT 953 200
5 R-2 DWELLING UNIT 1127 200
6 R-2 TRASH 53 300
1 R-2 ACCESSORY 87 300
1 R-2 MPOE 206 300
1 R-2 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 290.2 5.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" EXIT 41 STAIR 1 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 410.2 8.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" EXIT 41 STAIR 2 EXIT 42 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 220.2 4.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" STAIR 3 TOTAL INDOOR OCCUPANT LOAD = 124 124 OCCUPANTS/3 EXITS =41/42 OCC. PER EXIT FIRE WALL FIRE WALL CPET = 63'-2" CPET = 62'-9" CPET = 52'-9" L = 107'-8" L = 182'-11" L = 177'-7" OVERALL DIAGONAL DIMENSION = 309'-3 77/256" 1/3 OVERALL DIMENSION = 103'-2" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 234'-4 37/256" 1/3 OVERALL DIMENSION = 103'-2" STAIR 4 PARKING 16844 200 85 S-2 TOTAL PARKING OCCUPANT LOAD = 89 89 OCCUPANTS/3 EXITS =29/30 OCC. PER EXIT EXIT 29 EXIT 30 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 520.2 10.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 700.2 14" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" OVERALL DIAGONAL DIMENSION = 206'-8 127/128" 1/3 OVERALL DIMENSION = 68'-11" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1162'-10 95/128" 1/3 OVERALL DIMENSION = 68'-11" CPET = 28'-7" L = 111'-0" L = 169'-2" TRASH/LOADING 1209 300 5 R-2 FIRE PUMP 160 300
1 S-2 BOOSTER PUMP 170 300
1 S-2 BIKE STORAGE 435 300
2 S-2 EXIT 30 EXIT DISCHARGE MAIL 413 300
2 R-2 ELECTRICAL RM 340 300
2 R-2 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 280.2 5.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" 28 28 FRM
ABV EXIT DISCHARGE TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 420.2 8.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" 4229 FRM ABV EXIT DISCHARGE 70 ABV
51 FRM EXIT DISCHARGE TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 300.2 6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 300.2 6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" EXIT DISCHARGE 52 51 FRM ABV DINING AREA 525 15 35 A-3 FIRE PIT 546 15 37 A-3 TOTAL COURTYARD OCCUPANT LOAD = 72 72 OCCUPANTS/4 EXITS =36 OCC. PER EXIT EXIT 36 36 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 360.2 7.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 410.2 8.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" OVERALL DIAGONAL DIMENSION = 79'-0 33/256" 1/3 OVERALL DIMENSION = 26'-4" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 77'-3 187/256" 1/3 OVERALL DIMENSION = 26'-4" COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B FIRST FLOOR EXITING ANALYSIS BUILDING B - LEVEL 1 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 A0-41 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 City Council 23 – 3812/6/2022
CORRIDOR VENTILATION SHAFT CORRIDOR VENTILATION SHAFT CORRIDOR VENTILATION SHAFT IDF FEC SP SP FEC FEC
FEC STORAGE LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
ELEC LV LV
ELEC
LV ELEC
R W G UP 5% RAMP UP 93' (RUN) (5% SLOPE) = 4.65' (RISE) UP 3.5% DN 5% OPEN TO BELOW VAN
UP 5% UP DN UP EV EV EV EV
EV
EV EV EV
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC
FEC FEC LV ELEC LV ELEC
LV ELEC STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 IDF UPDN LV
ELEC UP UP DN DNUP TRASH VESTIBULE DWELLING UNIT 485 200 3 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 1262 200
7 R-2 DWELLING UNIT 908 200
5 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 1436 200
8 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 1436 200
8 R-2 DWELLING UNIT 1262 200
7 R-2 DWELLING UNIT 953 200
5 R-2 DWELLING UNIT 1127 200
6 R-2 TRASH 84 300
1 R-2 ACCESSORY 87 300
1 R-2 ACCESSORY 157 300
1 R-2 ACCESSORY 79 300
1 R-2 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 450.2 9" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 450.3 REQUIRED STAIR WIDTH 13.5" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 28 STAIR 1 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 450.2 9" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 450.3 REQUIRED STAIR WIDTH 13.5" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 45 STAIR 2 EXIT 46 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 460.2 9.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 460.3 REQUIRED STAIR WIDTH 13.8" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" STAIR 3 TOTAL RESIDENTIAL OCCUPANT LOAD = 136 136 OCCUPANTS/3 EXITS =45/46 OCC. PER EXIT FIRE WALL HORIZONTAL EXIT AT FIRE WALL PROVIDED FOR ACCESSIBLE MEANS OF EGRESS ONLY PER CBC 1009.2.1 EXCEPTION 1 FIRE WALL CPET = 63'-2" CPET = 62'-9" CPET = 52'-9" L = 115'-5" L = 194'-4" CPET = 48'-7" L = 177'-8" OVERALL DIAGONAL DIMENSION = 309'-6 185/256" 1/3 OVERALL DIMENSION = 103'-2" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 236'-0 27/256" 1/3 OVERALL DIMENSION = 103'-2" STAIR 4 PARKING 20444 200 103 R-2 TOTAL PARKING OCCUPANT LOAD = 103 103 OCCUPANTS/2 EXITS =51/52 OCC. PER EXIT EXIT 52 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 520.2 10.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 520.3 REQUIRED STAIR WIDTH 15.6" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" OVERALL DIAGONAL DIMENSION = 206'-8 127/128" 1/3 OVERALL DIMENSION = 68'-11" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 176'-3 217/256" 1/3 OVERALL DIMENSION = 68'-11" CPET = 28'-7" L = 181'-4" 51 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B SECOND FLOOR EXITING ANALYSIS BUILDING B - LEVEL 2 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 A0-42 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 City Council 23 – 3912/6/2022
FEC SP SP FEC FEC
FEC LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
LV
ELEC
ELEC LV LV
ELEC
LV ELEC
R W G UP 5% UP 5%
UP 3.5% DN 5% UP DN UP EV EV EV
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC
FEC FEC LV ELEC LV ELEC
LV ELEC STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 UPDN IDF DNUP UP UP DN TRASH VESTIBULE DWELLING UNIT 485 200 3 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 1262 200
7 R-2 DWELLING UNIT 908 200
5 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 1436 200
8 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 1436 200
8 R-2 DWELLING UNIT 1262 200
7 R-2 DWELLING UNIT 953 200
5 R-2 DWELLING UNIT 1127 200
6 R-2 TRASH 84 300
1 R-2 ACCESSORY 87 300
1 R-2 ACCESSORY 157 300
1 R-2 ACCESSORY 79 300
1 R-2 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 280.2 5.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 790.3 REQUIRED STAIR WIDTH 23.7" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 28 STAIR 1 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 280.2 5.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 280.3 REQUIRED STAIR WIDTH 8.4" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 28 STAIR 2 EXIT 29 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 290.2 5.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 280.3 REQUIRED STAIR WIDTH 8.7" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" STAIR 3 TOTAL RESIDENTIAL OCCUPANT LOAD = 85 85 OCCUPANTS/3 EXITS =28/29 OCC. PER EXIT FIRE WALL HORIZONTAL EXIT AT FIRE WALL PROVIDED FOR ACCESSIBLE MEANS OF EGRESS ONLY PER CBC 1009.2.1 EXCEPTION 1 FIRE WALL CPET = 63'-2" CPET = 62'-9" CPET = 52'-9" L = 115'-5" L = 194'-4" CPET = 48'-7" L = 177'-8" OVERALL DIAGONAL DIMENSION = 309'-6 185/256" 1/3 OVERALL DIMENSION = 103'-2" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 236'-0 27/256" 1/3 OVERALL DIMENSION = 103'-2" STAIR 4 PARKING 20444 200 103 R-2 TOTAL PARKING OCCUPANT LOAD = 103 103 OCCUPANTS/2 EXITS =51/52 OCC. PER EXIT EXIT 51 EXIT 52 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 520.2 10.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 520.3 REQUIRED STAIR WIDTH 15.6" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 510.2 10.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" OVERALL DIAGONAL DIMENSION = 206'-8 127/128" 1/3 OVERALL DIMENSION = 68'-11" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1162'-10 95/128" 1/3 OVERALL DIMENSION = 68'-11" CPET = 28'-7" L = 111'-0" L = 169'-2" COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B THIRD FLOOR EXITING ANALYSIS BUILDING B - LEVEL 3 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 A0-43 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 City Council 23 – 4012/6/2022
FEC SP SP FEC FEC
FEC LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
LV
ELEC
ELEC LV LV
ELEC
LV ELEC LV ELEC LV ELEC
LV ELEC STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 UPDN IDF DNUP UP UP DN
R W G DN UP
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC TRASH VESTIBULE DWELLING UNIT 485 200
3 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 1262 200
7 R-2 DWELLING UNIT 908 200
5 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 1436 200
8 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 1436 200
8 R-2 DWELLING UNIT 1262 200
7 R-2 DWELLING UNIT 953 200
5 R-2 DWELLING UNIT 1127 200
6 R-2 TRASH 84 300
1 R-2 ACCESSORY 87 300
1 R-2 ACCESSORY 157 300
1 R-2 ACCESSORY 79 300
1 R-2 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 280.2 5.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 790.3 REQUIRED STAIR WIDTH 23.7" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 28 STAIR 1 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 280.2 5.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 280.3 REQUIRED STAIR WIDTH 8.4" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 28 STAIR 2 EXIT 29 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 290.2 5.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 280.3 REQUIRED STAIR WIDTH 8.7" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" STAIR 3 TOTAL RESIDENTIAL OCCUPANT LOAD = 85 85 OCCUPANTS/3 EXITS =28/29 OCC. PER EXIT FIRE WALL HORIZONTAL EXIT AT FIRE WALL PROVIDED FOR ACCESSIBLE MEANS OF EGRESS ONLY PER CBC 1009.2.1 EXCEPTION 1 FIRE WALL CPET = 63'-2" CPET = 62'-9" CPET = 52'-9" L = 115'-5" L = 194'-4" CPET = 48'-7" L = 177'-8" OVERALL DIAGONAL DIMENSION = 309'-6 185/256" 1/3 OVERALL DIMENSION = 103'-2" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 236'-0 27/256" 1/3 OVERALL DIMENSION = 103'-2" STAIR 4 PARKING 20444 200 103 R-2 TOTAL PARKING OCCUPANT LOAD = 103 103 OCCUPANTS/2 EXITS =51/52 OCC. PER EXIT EXIT 51 EXIT 52 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 520.2 10.4" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 520.3 REQUIRED STAIR WIDTH 15.6" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 510.2 10.2" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH MIN. 33.4" 36" OVERALL DIAGONAL DIMENSION = 206'-8 127/128" 1/3 OVERALL DIMENSION = 68'-11" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1162'-10 95/128" 1/3 OVERALL DIMENSION = 68'-11" CPET = 53'-3" L = 94'-5" L = 169'-2" COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B FOURTH FLOOR EXITING ANALYSIS BUILDING B - LEVEL 4 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 A0-44 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 City Council 23 – 4112/6/2022
FEC SP SP FEC FEC
FEC LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
LV
ELEC
ELEC LV LV
ELEC
LV ELEC LV ELEC LV ELEC
LV ELEC
R W G STAIR B1 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 DN ELEVATOR MACHINE ROOM DN DN TRASH VESTIBULE ROOF ACCESS DWELLING UNIT 485 200 3 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 1262 200
7 R-2 DWELLING UNIT 908 200
5 R-2 DWELLING UNIT 1127 200
6 R-2 DWELLING UNIT 1436 200
8 R-2 DWELLING UNIT 1043 200
6 R-2 DWELLING UNIT 669 200
4 R-2 DWELLING UNIT 1436 200
8 R-2 DWELLING UNIT 1262 200
7 R-2 DWELLING UNIT 953 200
5 R-2 DWELLING UNIT 1127 200
6 R-2 TRASH 84 300
1 R-2 ACCESSORY 87 300
1 R-2 ACCESSORY 157 300
1 R-2 ACCESSORY 79 300
1 R-2 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 280.2 5.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 280.3 REQUIRED STAIR WIDTH 8.4" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 28 STAIR 1 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 280.2 5.6" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 280.3 REQUIRED STAIR WIDTH 8.4" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" EXIT 28 STAIR 2 EXIT 29 TOTAL OCCUPANTS REQUIRED OPENING WIDTH EGRESS WIDTH PER OCCUP EGRESS OPENING WIDTH 290.2 5.8" PROPOSED DOOR WIDTH PROPOSED OPENING WIDTH TOTAL OCCUPANTS EGRESS WIDTH PER OCCUP STAIR WIDTH 280.3 REQUIRED STAIR WIDTH 8.7" PROPOSED STAIR WIDTH 48" MIN. 33.4" 36" STAIR 3 TOTAL OCCUPANT LOAD = 85 85 OCCUPANTS/3 EXITS =28/29 OCC. PER EXIT FIRE WALL HORIZONTAL EXIT AT FIRE WALL PROVIDED FOR ACCESSIBLE MEANS OF EGRESS ONLY PER CBC 1009.2.1 EXCEPTION 1 FIRE WALL CPET = 63'-2" CPET = 62'-9" CPET = 52'-9" L = 115'-5" L = 194'-4" CPET = 48'-7" L = 177'-8" OVERALL DIAGONAL DIMENSION = 309'-6 185/256" 1/3 OVERALL DIMENSION = 103'-2" AT LEAST 2 EXIT SHALL BE SEPARATEDBY NOT LESS THAN 1/3 THE OVERALL DIMENSION - CBC SEC 1007.1.1 236'-0 27/256" 1/3 OVERALL DIMENSION = 103'-2" COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B FIFTH FLOOR EXITING ANALYSIS BUILDING B - LEVEL 5 EXITING ANALYSIS SCALE: 3/32"=1'-0" 1 A0-45 3-HR FIRE WALL - SEE AD-26 1. REFER TO FIRE PROTECTION NOTES . 1.1. PROVIDE AUTOMATIC FIRE SPRINKLER SYSTEM 1.2. PROVIDE FIRE ALARM SYSTEM 1.3. PROVIDE STANDPIPES 2. PROVIDE MEANS OF EGRESS IDENTIFICATION PER CBC SECTION 1013: 2.1. EXIT SIGNS (EXCEPT TACTILE SIGNS) SHALL BE INTERNALLY OR EXTERNALLY ILLUMINATED. 2.2. TACTILE EXIT SIGNS SHALL BE PROVIDED AT THE FOLLOWING LOCATION (REFER TO SEGMENT FLOOR PLANS FOR SPECIFIC LOCATIONS): A) EACH GRADE LEVEL EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1013.4. B) EXIT DOORS REQUIRED TO COMPLY WITH CBC SECTION 1011.1, AND LEAD DIRECTLY TO A GRADE LEVEL EXTERIOR EXIT BY MEANS OF STAIRWAY OR RAMP SHALL BE IDENTIFIED AS: i) "EXIT STAIR DOWN" ii) "EXIT RAMP DOWN" iii) "EXIT STAIR UP" iv) "EXIT RAMP UP" 2.3 INTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.5. 2.4 EXTERNALLY ILLUMINATED EXIT SIGNS SHALL CONFORM WITH CBC SECTION 1013.6. A) EXIT SIGN GRAPHICS SHALL COMPLY WITH CBC SECTION 1013.6.1. B) THE FACE OF EXIT SIGN SHALL BE ILLUMINATED WITH AN INTENSITY OF NO LESS THAN 5 FOOTCANDLES (45 LUX). C) EXIT SIGNS SHALL BE ILLUMINATED AT ALL TIMES. D) PROVIDE BACKUP POWER IN CASE OF PRIMARY POWER LOSS IN CONFORMANCE WITH CBC SECTION 1013.6.3. 2.5 ADDITIONAL EXIT SIGNS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT CHANGE DURING FINAL INSPECTION. 3. PROVIDE FIRE EXTINGUISHERS: 3.1. PROVIDE A MINIMUM OF ONE 2-A:10-B:C (2A:20BC WITHIN 50'-0" AT GARAGE) CLASSIFICATION FIRE EXTINGUISHER WITHIN 75 FEET TRAVEL DISTANCE FOR EACH 6,000 SQUARE FEET OR PORTION THEREOF ON EACH FLOOR. 3.2. ADDITIONAL FIRE EXTINGUISHERS MAY BE REQUIRED AND LOCATIONS ARE SUBJECT TO CHANGE DURING FINAL INSPECTION. 4. EACH DWELLING UNIT SHALL HAVE PERMANENTLY WIRED SMOKE ALARMS WITH BATTERY BACKUP INSIDE EACH BEDROOM AND CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO SLEEPING AREAS. SMOKE ALARMS SHALL SOUND AN ALARM AUDIBLE IN ALL SLEEPING AREA OF THE UNIT. 5. INTERIOR FINISHES SHALL COMPLY WITH CBC CHAPTER 8. 6. THE MEANS OF EGRESS, INCLUDING THE EXIT DISCHARGE, WILL BE ILLUMINATED TO A LEVEL NOT LESS ONE FOOT CANDLE AT WALKING SURFACE AT ALL TIMES THE BUILDING SPACE SERVED BY THE MEANS OF EGRESS IS OCCUPIED. 7. SIGNAGE INDICATING SPECIAL ACCESSIBILITY PROVISIONS SHALL COMPLY WITH CHAPTER 11A, SECTION 1143A. 1. THE ACCESSIBLE MEANS OF EGRESS SYSTEM CONSISTS OF THE FOLLOWING: A. ACCESSIBLE ROUTE -SAME AS PATH OF EGRESS (INDICATED IN LEGEND AND SHOWN BY SYMBOL) B1. ELEVATOR REQUIRED PER CBC 1009.2.1 ONE ELEVATOR IS REQUIRED ACCESSIBLE MEANS OF EGRESS AND IS COMPLYING WITH SECTION 1009.4. OR B2. ELEVATOR NOT REQUIRED PER CBC 1009.2.1 AND EXCEPTION #1, ELEVATOR IS NOT REQUIRED AS AN ACCESSIBLE MEANS OF EGRESS. C. INTERIOR STAIRWAYS: INTERIOR STAIRWAYS COMPLY WITH CBC 1009.3 EXCEPTIONS #2 AND #5. REQUIRED STAIR WIDTH (CBC 1005.3.1) OCCUPANT LOAD X 0.3" = (REQ'D STAIR WIDTH) REQUIRED DOOR AND OTHER EGRESS COMPONENTS WIDTH (CBC 1005.3.2 ) OCCUPANT LOAD X 0.2" = REQ'D WIDTH OF EGRESS COMPONENTS AREAS CALCULATED S-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 400 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 R-2 EXITING REQUIREMENTS: BASED ON CBC TABLE 1004.5: (200 GROSS SF) PER OCCUPANT TRAVEL DISTANCE PER CBC TABLE 1017.2 250 FEET W/ FIRE SPRINKLERS PER CBC 903.3.1.1 OR 903.3.1.2 DISTANCE BETWEEN EXITS SHALL COMPLY WITH CBC 1007.1.1 EXIT ACCESS TRAVEL DISTANCE, SEE ALSO TRAVEL DISTANCE SCHEDULE MOST REMOTE POINT TO EXIT ACCESS HORIZONTAL EXIT EXIT AND OCCUPANT LOAD OCCUPANT SPACE/FUNCTION OCCUPANT LOAD SF/OCCUPANT OCCUPANCY TYPE FIRE EXTINGUISHER CABINET MAX. 75'-0" O.C., SEE DETAIL Name 10000 SF 100 50 R-2 XX
EXIT
00 OCCUPANT LOAD SCHEDULE Name Area Occ. Load Factor Occ. Load HE XX XX.XX FLOOR AREA # OF OCCUPANTS F.E.C. STANDPIPE EXIT PLAN NOTES SYMBOL LEGEND ACCESSIBLE MEANS OF EGRESS L = XX' CPET = XX' COMMON PATH OF EGRESS TRAVEL DISTANCE INTERIOR EXIT STAIR HORIZONTAL EXIT REFUGE AREA EXIT SIGN PER CBC SECTION 1013 City Council 23 – 4212/6/2022
COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL CONDITIONS OF APPROVALA0-70 City Council 23 – 4312/6/2022
COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL CONDITIONS OF APPROVALA0-71 City Council 23 – 4412/6/2022
CONDITIONS OF APPROVALA0-71 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 4512/6/2022 CONDITIONS OF APPROVALA0-72 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 4612/6/2022 CONDITIONS OF APPROVALA0-73 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 4712/6/2022 CONDITIONS OF APPROVALA0-74 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 4812/6/2022 CONDITIONS OF APPROVALA0-75 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 4912/6/2022
COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL GEOTECHNICAL REPORT A0-80 City Council 23 – 5012/6/2022
COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL GEOTECHNICAL REPORT A0-81 City Council 23 – 5112/6/2022
GEOTECHNICAL REPORT A0-82 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 5212/6/2022 GEOTECHNICAL REPORT A0-83 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 5312/6/2022 GEOTECHNICAL REPORT A0-84 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 5412/6/2022 GEOTECHNICAL REPORT A0-85 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 5512/6/2022 GEOTECHNICAL REPORT A0-86 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 5612/6/2022 GEOTECHNICAL REPORT A0-87 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 5712/6/2022 GEOTECHNICAL REPORT A0-88 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 5812/6/2022 GEOTECHNICAL REPORT A0-89 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 5912/6/2022 GEOTECHNICAL REPORT A0-90 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 6012/6/2022
COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL EXTERIOR ACOUSTICAL ANALYSIS REPORT A0-91 City Council 23 – 6112/6/2022
EXTERIOR ACOUSTICAL ANALYSIS REPORT A0-92 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 6212/6/2022 EXTERIOR ACOUSTICAL ANALYSIS REPORT A0-93 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 6312/6/2022 EXTERIOR ACOUSTICAL ANALYSIS REPORT A0-94 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 6412/6/2022
COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL ADDRESSING PLANS & USPS APPROVAL A0-95 City Council 23 – 6512/6/2022
ADDRESSING PLANS & USPS APPROVAL A0-96 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 6612/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-97 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 6712/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-98 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 6812/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-99 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 6912/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-100 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 7012/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-101 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 7112/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-102 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 7212/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-103 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 7312/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-104 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 7412/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-105 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 7512/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-106 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 7612/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-107 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 7712/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-108 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 7812/6/2022 ADDRESSING PLANS & USPS APPROVAL A0-109 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 7912/6/2022 City Council 23 – 80 12/6/2022
POLICE DEPARTMENT BUILDING SECURITY REGULATIONSA1-21 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 8112/6/2022 POLICE DEPARTMENT BUILDING SECURITY REGULATIONS A1-22 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 8212/6/2022 POLICE DEPARTMENT BUILDING SECURITY REGULATIONS A1-23 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 8312/6/2022
COFFEE/HOSPITALITY TRASH RECY TV
U/C REF WATER BOTTLE
FILLER
TRASH RECY CUBBIES
W R F
R
W
G PROTECTED BIKE LANE PROTECTED BIKE LANE FIFTH STREET FOURTH STREET
FRENCH STREET
MORTIMER STREET
MINTER STREET KB KB KB KB KB KB KB KB KB KB KB KB KB 150' 150'
150'
122'
150'
150' ROOF ACCESS STAIR ROOF ACCESS STAIR - DIRECT ACCESS TO LEVEL 3 POOL DECK ROOF ACCESS STAIR 8' MIN.
PARKING
20'-0" MIN.
FIRE LANE
8' MIN.
PARKING
20'-0" MIN.
FIRE LANE
20'-0" MIN.
FIRE LANE 8'-0" PARKING 24'-0" FIRE LANE 20' MIN. 8'-0" PARKING 97' 8'-0" PARKING 24'-0" FIRE LANE 20' MIN. 8'-0" PARKING 20'-0" MIN.
FIRE LANE
8'-0"
PARKING
20'-0" MIN.
FIRE LANE EXISTING 1-STORY AUTO SHOP 20'-0" MIN. FIRE LANE 1 2
2 1
1 27'-6" ROOF ACCESS STAIR ROOF ACCESS STAIR ROOF ACCESS STAIR 3 3 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL FIRE ACCESS PLAN A1-30 1. PROVIDE AN ELECTRIC KNOX BOX KEYED OVERRIDE SWITCH BUILDING ENTRANCE 150' HOSE MAX PULL W/ FIRE TRUCK 150' HOSE PULL STANDPIPE IN STAIR ENCLOSURES FIRE WALL FIRE HYDRANT XX ACTUAL HOSE PULL FROM STANDPIPE OR FIRE HYDRANT FIRE ACCESS TO THE ENTRY DOOR OF FURTHEST UNIT IS NO MORE THAN 300' MAX FROM FIRE HYDRANT (AS DEMONSTRATED): 150' MAX FROM THE FIRE HYDRANT TO THE BUILDING ACCESS POINT + 150' MAX TO THE UNIT ENTRY DOOR EXPOSED STANDPIPE OR IN WALL WITH ACCESS PANEL - CLASS I *KB KNOX BOX KOS KEYED OVERRIDE SWITCH FIRE HYDRANTS PER FIRE CODE SEC 57.09.06.B ALL PORTIONS OF THE EXTERIOR WALLS IS NO MORE THAN 300' FROM A PUBLIC OR PRIVATE FIRE HYDRANT. FIRE APPARATUS ACCESS ROADS PER FIRE CODE SEC 503.1.1 THE FIRE APPARATUS ACCESS ROAD SHALL EXTEND TO WITHIN 150 FEET OF ALL PORTIONS OF THE FACILITY AND ALL PORTIONS OF THE EXTERIOR WALLS OF THE FIRST STORY OF THE BUILDING AS MEASURED BY AN APPROVED ROUTE AROUND THE EXTERIOR OF THE BUILDING OR FACILITY. 1 6' TALL SECURITY GATE 2 3' TALL SWING GATE - NO LATCHING OR LOCKING MECHANISM TO BE INSTALLED FIRE ACESS LANES ALL FIRE ACCESS LANES AROUND THE SITE ARE MARKED WITH PRE-EXISTING SIGNAGE. STAIR ENCLOSURE ELEVATOR SHAFT3 BUILDING ADDRESS SIGNAGE. REFER TO ELEVATIONS. FIRE ACCESS PLAN SCALE: 1"=20' 1 City Council 23 – 8412/6/2022
COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed.
Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL FIRE FLOW TEST REPORTA1-30.1 City Council 23 – 8512/6/2022
COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL CALCULATED GRADE PLANE & BUILDING HEIGHT A1-40 BUILDING # City Council 23 – 8612/6/2022
COFFEE/HOSPITALITY TRASH RECY TV
U/C REF WATER BOTTLE
FILLER
TRASH RECY CUBBIES
W R F
41'-3"
UNLIMITED OPNG
40'-4"
UNLIMITED OPNG 33'-4" UNLIMITED OPNG 43'-4" UNLIMITED OPNG 32'-11" UNLIMITED OPNG 36'-3" UNLIMITED OPNG 40'-6" UNLIMITED OPNG 44'-4"
UNLIMITED OPNG
33'-5 23/128"
UNLIMITED OPNG COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL EXTERIOR OPENING ANALYSIS BUILDING A A1-50 FIRE SEPARATION DISTANCE LEVEL 1 SCALE: 1/16"=1' 1 OPENING AREA USED FOR ANALYSIS WALL AREA USED FOR ANALYSIS 10' TO <15' 45% OPNG MAX FIRE SEPARATION DISTANCE BASED ON SITE ADJACENCIES MAXIMUM ALLOWABLE OPENING BASED ON FIRE SEPARATION DISTANCE; SEE CBC TABLE 705.8 EXTENTS OF A SPECIFIED FIRE SEPARATION DISTANCE ON ELEVATION OPENING ANALYSIS LEGEND (X) SF X SF IMAGINARY LOT LINE PROPERTY LINE CENTERLINE OF STREET City Council 23 – 8712/6/2022 E
E
D
D
D
E
G R W SP SP
LV
LV ELEC
LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV ELEC EV FEC UP DN DNUP (2)WARMING D/W ICE REF U/C MICRO DRAWERS TRASHRECY
FEC FEC
FEC 2% MIN. 9% MIN. 2% MIN. 2% MIN. 2% MIN. 4% MIN. 3.5% MIN. 3.5% MIN. 9% MIN. 9% MIN. 11% MIN. 3% MIN. 7% MIN. 3% MIN. 4.6% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3% MIN. 3% MIN. 4% MIN. 4% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 4% MIN. 4% MIN. 3% MIN. 3% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 5% MIN. 5% MIN. 3% MIN. 3% MIN. 3% MIN. 3% MIN. 5% MIN. 5% MIN. 4% MIN. 4% MIN. 3% MIN. 3% MIN. 3% MIN. 5% MIN. 5% MIN. 5% MIN. 5% MIN. 7% MIN. 7% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3% MIN. 3% MIN. 3% MIN. 3% MIN. 2% MIN. 4% MIN. 7% MIN. 2% MIN. 22'-1" UNLIMITED OPNG COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL EXTERIOR OPENING ANALYSIS BUILDING A A1-51 FIRE SEPARATION DISTANCE LEVEL 3 SCALE: 1/16"=1' 1 OPENING AREA USED FOR ANALYSIS WALL AREA USED FOR ANALYSIS 10' TO <15' 45% OPNG MAX FIRE SEPARATION DISTANCE BASED ON SITE ADJACENCIES MAXIMUM ALLOWABLE OPENING BASED ON FIRE SEPARATION DISTANCE; SEE CBC TABLE 705.8 EXTENTS OF A SPECIFIED FIRE SEPARATION DISTANCE ON ELEVATION OPENING ANALYSIS LEGEND (X) SF X SF IMAGINARY LOT LINE PROPERTY LINE CENTERLINE OF STREET City Council 23 – 8812/6/2022 R
W
G29'-10" UNLIMITED OPNG 23'-9" UNLIMITED OPNG 41'-10" UNLIMITED OPNG 22'-8" UNLIMITED OPNG 41'-1"
UNLIMITED OPNG
40'-4"
UNLIMITED OPNG 34'-11" UNLIMITED OPNG 40'-1" UNLIMITED OPNG 41'-6"
UNLIMITED OPNG
34'-9"
UNLIMITED OPNG 38'-2" UNLIMITED OPNG 44'-4" UNLIMITED OPNG 12'-10"
45% OPNG 10'-11 103/256" 45% OPNG 11'-3" 45% OPNG 91'-0" UNLIMITED OPNG 27'-9" UNLIMITED OPNG COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL EXTERIOR OPENING ANALYSIS BUILDING B A1-52 FIRE SEPARATION DISTANCE LEVEL 1 SCALE: 1/16"=1' 1 OPENING AREA USED FOR ANALYSIS WALL AREA USED FOR ANALYSIS 10' TO <15' 45% OPNG MAX FIRE SEPARATION DISTANCE BASED ON SITE ADJACENCIES MAXIMUM ALLOWABLE OPENING BASED ON FIRE SEPARATION DISTANCE; SEE CBC TABLE 705.8 EXTENTS OF A SPECIFIED FIRE SEPARATION DISTANCE ON ELEVATION OPENING ANALYSIS LEGEND (X) SF X SF IMAGINARY LOT LINE PROPERTY LINE CENTERLINE OF STREET City Council 23 – 8912/6/2022 UNIT 1.1F UNIT 2.2P CORRIDOR UNIT 2.2P UNIT 1.1F UNIT 1.3B UNIT 2.1Q CORRIDOR UNIT 4.1L UNIT 4.1M UNIT 3.1B ELECTRICAL ROOM UNIT 3.1A H
D
H
D
H
D
H
D
H
D
P
L
A
N
E
F 20< UNLIMITED OPENINGS ALLOWED 10' TO <15' 45% OPEN 20< UNLIMITED OPENINGS ALLOWED 5 1139 S. F. 354 S.F. 31.1%
4 1139 S. F. 354 S.F. 31.1%
3 1139 S. F. 354 S.F. 31.1%
2 1,139 S.F. 354 S.F. 31.1%
1 1,252 S.F. 282 S.F. 22.5% OK
(1252 S.F.) 18 S.F. 24 S.F. 24 S.F. 18 S.F. 24 S.F. 24 S.F. 24 S.F. 36 SQ. FT. 24 S.F. 24 S.F. 18 S.F. 24 S.F.(1139 S.F.) 24 S.F. 24 S.F. 18 S.F. 24 S.F. 24 S.F. 24 S.F. 36 SQ. FT. 24 S.F. 24 S.F. 18 S.F. 24 S.F. 35 S.F. 55 S.F.(1139 S.F.) 24 S.F. 24 S.F. 18 S.F. 24 S.F. 24 S.F. 24 S.F. 36 SQ. FT. 24 S.F. 24 S.F. 18 S.F. 24 S.F. 35 S.F. 55 S.F.(1139 S.F.) 24 S.F. 24 S.F. 18 S.F. 24 S.F. 24 S.F. 24 S.F. 36 SQ. FT. 24 S.F. 24 S.F. 18 S.F. 24 S.F. 35 S.F. 55 S.F.(1139 S.F.) 24 S.F. 24 S.F. 18 S.F. 24 S.F. 24 S.F. 24 S.F. 36 SQ. FT. 24 S.F. 24 S.F. 18 S.F. 24 S.F. 35 S.F. 55 S.F.
H
D
H
D
H
D
H
D
H 20< UNLIMITED OPENINGS ALLOWED 10' TO <15' 45% OPEN
5 363 S. F. 32 S.F. 8.8%
4 363 S. F. 32 S.F. 8.8%
3 363 S. F. 32 S.F. 8.8%
2 363 S.F. 32 S.F. 8.8%
1 399 S.F. 10 S.F. 2.5% OK 18 S.F. 18 S.F. 18 S.F. 18 S.F. 10 S.F. 14 S.F. 14 S.F. 14 S.F. 14 S.F. (399 S.F.)
(363 S.F.)(363 S.F.)(363 S.F.)(363 S.F.) COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL EXTERIOR OPENING ANALYSIS BUILDING B A1-53 BUILDING B EAST ELEVATION SCALE: 1/8"=1' 1 OPENING AREA USED FOR ANALYSIS WALL AREA USED FOR ANALYSIS 10' TO <15' 45% OPNG MAX FIRE SEPARATION DISTANCE BASED ON SITE ADJACENCIES MAXIMUM ALLOWABLE OPENING BASED ON FIRE SEPARATION DISTANCE; SEE CBC TABLE 705.8 EXTENTS OF A SPECIFIED FIRE SEPARATION DISTANCE ON ELEVATION OPENING ANALYSIS LEGEND (X) SF X SF IMAGINARY LOT LINE PROPERTY LINE CENTERLINE OF STREET BUILDING B SOUTH ELEVATION SCALE: 1/8"=1'1 City Council 23 – 9012/6/2022 9 8.8
8 7
6 5 4.3
3 128.58' 140.46' 150.54' 160.63'
5 439'-4" 439'-4" 100%
4 617'-4" 356-11" 57.8%
3 617'-4" 207'-6" 33.6%
2 617'-4" 186'-4" 30.1%
1 617'-4" 177'-4" 28.7%
4 2,708 S.F. 907 S.F. 33.4%
3 5,625 S.F. 1,325 S.F. 23.5%
2 5,549 S.F. 1,191 S.F. 21.4%
1 6,243 S.F. 1,305 S.F. 20.9% 241 S.F. 166 S.F. 166 S.F. 166 S.F. 181 S.F. 192 S.F. 192 S.F. 192 S.F. 181 S.F. 181 S.F. 181 S.F. 167 S.F. 167 S.F. 167 SQ. FT. 853 S.F. 853 S.F. 853 S.F. TIER 1 TIER 2 TIER 1 TIER 3 634 S.F. TIER 2 634 S.F. TIER 3 634 S.F. TIER 4 673 S.F. 3 283 S.F. 704 S.F. 237.8% 2 283 S.F. 526 S.F. 177.7%
1 309 S.F. 539 S.F. 176.0%
A
B C.2
D
G G.7
K
L
M 128.58' 140.46' 150.54' 160.63'
F A2-42 161 S.F. 161 S.F. 161 S.F. 162 S.F. 138 S.F. 138 S.F. 134 S.F. 186 S.F. 186 S.F. 212 S.F. TIER 1 TIER 2 TIER 3 1221 S.F. 1059 S.F. 1059 S.F. EXTERIOR OPENING ANALYSIS BUILDING A GARAGE A1-54 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL OPENING AREA USED FOR ANALYSIS WALL AREA USED FOR ANALYSIS 10' TO <15' 45% OPNG MAX FIRE SEPARATION DISTANCE BASED ON SITE ADJACENCIES MAXIMUM ALLOWABLE OPENING BASED ON FIRE SEPARATION DISTANCE; SEE CBC TABLE 705.8 EXTENTS OF A SPECIFIED FIRE SEPARATION DISTANCE ON ELEVATION OPENING ANALYSIS LEGEND (X) SF X SF IMAGINARY LOT LINE PROPERTY LINE CENTERLINE OF STREET BUILDING A - GARAGE NORTH ELEVATION SCALE: 1/8"=1' 1 BUILDING A - GARAGE WEST ELEVATION SCALE: 1/8"=1'2
City Council 23 – 9112/6/2022 945 S.F. 837 S.F. 837 S.F. 845 S.F. TIER 1 TIER 2 TIER 3 TIER 4 1114 S.F. 991 S.F. 977 S.F. TIER 1 TIER 2 TIER 3 REFER TO A1-54 FOR INFORMATION NOT SHOWN REFER TO A1-54 FOR INFORMATION NOT SHOWN 1437 S.F. 1175 S.F. 1237 S.F. 1237 S.F. TIER 1 TIER 2 TIER 3 TIER 4 EXTERIOR OPENING ANALYSIS BUILDING A GARAGE A1-55 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A - GARAGE SOUTH ELEVATION SCALE: 1/8"=1' 1 BUILDING A - GARAGE EAST ELEVATION SCALE: 1/8"=1'2 OPENING AREA USED FOR ANALYSIS WALL AREA USED FOR ANALYSIS 10' TO <15' 45% OPNG MAX FIRE SEPARATION DISTANCE BASED ON SITE ADJACENCIES MAXIMUM ALLOWABLE OPENING BASED ON FIRE SEPARATION DISTANCE; SEE CBC TABLE 705.8 EXTENTS OF A SPECIFIED FIRE SEPARATION DISTANCE ON ELEVATION OPENING ANALYSIS LEGEND (X) SF X SF IMAGINARY LOT LINE PROPERTY LINE CENTERLINE OF STREET City Council 23 – 9212/6/2022 22 20 17 15 14 11
8 169 S.F. 151 S.F. 131 S.F. 289 S.F. TIER 1 761 S.F. 208 S.F. TIER 1 904 S.F. TIER 2 860 S.F. TIER 2 675 S.F. TIER 3 645 S.F. TIER 3 623 S.F. 4 367'-5" 367'-5" 100.0%
3 616'-8" 286'-5" 46.4%
2 616'-8" 213'-5 1/2" 34.6%
1 616'-8" 205'-8 1/2" 33.3%
3 5,415 S.F. 1,884 S.F. 34.7%
2 5,572 S.F. 1,210 S.F. 21.7%
1 6,590 S.F. 1,305 S.F. 19.8%
3 369 S.F. 644 S.F. 174.5%
2 369 S.F. 644 S.F. 174.5%
1 405 S.F. 676 S.F. 166.9% 179 S.F. 183 S.F. 183 S.F. 195 S.F. 161 S.F. 220 S.F. 169 S.F.
L
K
J H.7
H
E
D
A 160 S.F. 242 S.F. 235 S.F. 242 S.F. TIER 1 1281 S.F. TIER 2 1057 S.F. TIER 3 1059 S.F. 253 S.F. 258 S.F. 235 S.F. EXTERIOR OPENING ANALYSIS BUILDING B GARAGE A1-56 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL OPENING AREA USED FOR ANALYSIS WALL AREA USED FOR ANALYSIS 10' TO <15' 45% OPNG MAX FIRE SEPARATION DISTANCE BASED ON SITE ADJACENCIES MAXIMUM ALLOWABLE OPENING BASED ON FIRE SEPARATION DISTANCE; SEE CBC TABLE 705.8 EXTENTS OF A SPECIFIED FIRE SEPARATION DISTANCE ON ELEVATION OPENING ANALYSIS LEGEND (X) SF X SF IMAGINARY LOT LINE PROPERTY LINE CENTERLINE OF STREET BUILDING B - GARAGE NORTH ELEVATION SCALE: 1/8"=1' 1 BUILDING B - GARAGE EAST ELEVATION SCALE: 1/8"=1'2
City Council 23 – 9312/6/2022 TIER 1 2173 S.F. TIER 2 1866 S.F. TIER 3 1866 S.F. REFER TO A1-56 FOR INFORMATION NOT SHOWN TIER 2 1142 S.F. TIER 3 1222 S.F. TIER 1 1471 S.F. REFER TO A1-56 FOR INFORMATION NOT SHOWN EXTERIOR OPENING ANALYSIS BUILDING B GARAGE A1-57 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL OPENING AREA USED FOR ANALYSIS WALL AREA USED FOR ANALYSIS 10' TO <15' 45% OPNG MAX FIRE SEPARATION DISTANCE BASED ON SITE ADJACENCIES MAXIMUM ALLOWABLE OPENING BASED ON FIRE SEPARATION DISTANCE; SEE CBC TABLE 705.8 EXTENTS OF A SPECIFIED FIRE SEPARATION DISTANCE ON ELEVATION OPENING ANALYSIS LEGEND (X) SF X SF IMAGINARY LOT LINE PROPERTY LINE CENTERLINE OF STREET BUILDING B - GARAGE SOUTH ELEVATION SCALE: 1/8"=1' 1 BUILDING B - GARAGE WEST ELEVATION SCALE: 1/8"=1'2
City Council 23 – 9412/6/2022 1 20
1 4.4 5.2 6.2 7.2 8.2 8.5 10.3 11 12 13
LL.6
L P.5R
T
R
TH.8
P
P
N
N
Q
Q
S
S 8.7 9.6 9.7 10.110.2 Q.1 Q.2 P.7
2 2.1 11.2 11.511.7
M R.5 S.4 P.4 P.2 P.3 P.6 N.1 N.4 N.2 N.3
MM.1 M.2 M.4 M.3 244'-6" 4'-5" 2'-5" 24'-5 1/2" 27'-7 1/2" 30'-1" 30'-4" 30'-4" 16'-3 1/2" 31'-11 1/2" 14'-1" 27'-0" 5'-6" 16'-8 5/8" 13'-9" 4'-5" 17'-9 1/2" 2'-7 1/2" 3'-9" 1'-4" 2'-0 1/2" 3'-7 1/2" 12'-2 1/2" 5'-4 7/8" 5'-9 1/8" 108'-10"
9'-1" 8'-2 1/2" 22'-3 1/2" 21'-7 1/4" 18'-7 1/2" 9'-2 3/4" 7'-2 3/4"
2'-11 3/4"
9" 11'-4" 6'-3" 8'-3 1/4" 1'-7 3/4" 4'-6"
116'-5 7/8"
9'-1 1/8" 8'-2 1/2" 19'-9 1/2" 22'-3 1/2" 21'-7 1/4" 18'-7 1/2" 9'-2 3/4" 5'-8 5/8"3'-4 1/2" 3'-10 1/2" 1'-2 3/4" 9" 2'-10 1/2" 1'-1 1/4"11'-1 3/4" 2'-6 1/2" 1'-0" 1'-3 3/4" 2 3/4"
9'-0 3/4" 7'-7 3/4" 4.8 5.5
19'-9 1/2" LV ELEC RETAIL RESTAURANT KITCHEN/ STORAGE PUBLIC LOBBY
LV ELEC
LV
ELEC
LV
ELEC CORRIDOR VENTILATION SHAFT (2) FUTURE GREASE SHAFTS ABOVE CORRIDOR VENTILATION SHAFT UP UP UP UP UP TURN-AROUND SPOT TRASH / LOADING VAN BIKE FIRE PUMP ROOM BOOSTER PUMP ROOM STAIR A1 STAIR A2 TURN AROUND SPOT VAN VAN 3.2 3.4
4 5 5.1
6 7
8 8.8
9 10
BAC.2C
D
E
FG
H
KJ.5 G.9 G.7
3 4.3 8.9 185'-4" 16'-4" 31'-6" 28'-6" 31'-6" 30'-0" 31'-6" 16'-0" 1'-5" 3'-8" 11'-3" 2'-9" 1'-3" 2'-8" 1'-6" 123'-4"
13'-3" 30'-0" 13'-6" 4'-0" 13'-4" 30'-2" 14'-8" 1'-8"
2'-9" 2'-3"3'-10" 9"
J
2'-9"
2'-0" 6.1 UP 5% 123.44' 123.44' 123.44' 123.44' 124.04' 124.04' 124.04' 124.04' 127.04' 127.04' 127.04' 127.04' 127.04' 128.58' 128.58' 128.58' 128.58' 127.04' 128.58' 128.58' 124.70' 123.87' 123.14' 124.90' 124.90' 124.47' 125.07' 124.57' 124.72' 125.02' 124.49' 123.87' 124.52' 126.56' 127.36' 124.90' UP 5% UP 2% UP 5%
EV EV EV DN 4.5%
FEC
FEC FEC
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ PARCEL ROOM STAIR A4 STAIR A3
LV
ELEC ELEV A1 ELEV A2 IDF CORRIDOR VENTILATION SHAFT UP
DN 2.2% UP UP UP MPOE DN 4.5% 1.8% DN DN
1.8% DN 1.5%DN 4.5% DN
4.5% DN
1.3% DN 1.5% DN
4.5% TV
TRASH RECY REF SP SP
W R F
FEC
FEC
FEC
ELEC UP FITNESS LEASING OFFICE TRASH VESTIBULE UNIT 0.3A A101 A5-03 1 A2-21
2 A2-20
2 A2-21 UNIT 4.1A-R A102 A5-33UNIT 1.3A A103 A5-14 UNIT 2.1D-R A104 A5-22 UNIT 3.3A A105 A5-40 UNIT 3.2A A106 A5-38 3 3 3
4 3
3 33
3 3 3 3
3 3 3 3 3 3
3 333
3 4
4 4 4 4 4 4
4 4 4 4 4 4 4
6 6
6 7
7 7
7 7
A A2-40B A2-40
E A2-42
D A2-41
CA2-41
3 3 6 7
1 A5-74
1 A5-76
1 A5-72
1 A5-70
2 A5-90
1 A5-94
1 A5-54
1 A5-50
1 A5-52
1'-0" 50'-5" 16'-5 1/2" 25'-0" 7'-6" 7'-2 1/2" 2'-5" 1'-0" 10'-3" 1'-0 3/4" 126'-7"
9" 53'-2" 36'-2" 6" 36'-0"
18'-4" 42'-10 1/2"
18'-4" 43'-0 1/2" 2"
11'-0 1/4" A101 A102 A103 A104 A105 A106 A107 A108 A109 A110 A111 A112 A113 A115 A117 A116 A118 A119 A120 A121 A122 A123 A124 A125 A126A127 A128 A129 A130 A131 A132 A134 A133 A135 A136 A137 A138A139 A140 A141 A143 A142 A114 A144 14 10A 11 14'-5"
13'-4" 12'-0" 2'-0" 33'-4"
F A2-42
GA2-43
1 A2-20 BUILDING A FIRST LEVEL FLOOR PLAN BUILDING A FIRST FLOOR PLAN SCALE: 3/32"=1'-0" 1 A2-11 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING COMPOSITE PLAN NOTES 6 AD-31 1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. 2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE LEGAL ADDRESS. 3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE 4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. 6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON 7. THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY 8. WITH CBC 803. 9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. 10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATED ACCESS PANELS WITH SELF CLOSING DEVICES. 11. PROVIDE ACOUSTICAL ASSEMBLIES PER 12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. 13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER 14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. 15. SEE STRUCTURAL DRAWINGS FOR: A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING B) SPECIAL NAILING AND BLOCKING REQUIREMENTS 15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE VENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER PROTECTION SHALL BE EXTENDED TO THOSE AREAS. 16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED AND APPROVED. 17. PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTION THROUGHOUT. 18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) 19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE PROTECTION PER 20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FOR SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. 21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR SECURITY AND SAFETY. 22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. - AD-XX ALL AD-02.1 ALL AD-01 TO KEYNOTES MECHANICAL SHAFT - SEE MECHANICAL DWGS LINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF, SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH LOCAL FIRE AUTHORITY. BUILDING PLAN LEGEND DOOR SYMBOL FLOOR DRAIN - SEE PLMB XX WINDOW & STOREFRONT SYMBOL - A7-20
- A7-40 X FEC AD-XX DS DOWNSPOUT
X AD-XX WATERPROOF TRAFFIC COATING FD DIRECTION OF SLOPE - 1/4" / FT U.N.O.
X AD-XX 3-HR RATED FIRE WALL CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) ALL AD-20 18 AD-22 12 - A7-10
- A7-30 ACCESSIBLE PARKING SPACE
X AD-XXX AD-XX WATERPROOF TRAFFIC COATING FRAMED WALL - 6" METAL STUD CONCRETE COLUMN MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. FULL HEIGHT STEEL FENCING -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" 16 AD-31 40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEX AD-XX FRAMED WALL - 3-5/8" METAL STUD AIRCRAFT CABLE VEHICULAR BARRIER SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB -6" TOC X AD-XX CONCRETE WHEEL STOP DETECTABLE WARNINGS, MIN 36" WIDEX AD-XX CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) COLUMN CAP CMU WALL - SEE STRUCTURAL FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB CONCRETE WALL - SEE STRUCTURAL CONCRETE STRUCTURAL SLAB TRANSITIONS 3 RETAIL PARKING SPACE4 GUEST PARKING SPACE5 EV READY SPACE (FUTURE) 6 EV CHARGING SPACE (INSTALLED),REFER TO DETAIL 9/AD-31 7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR 10 3 AD-31 12 AD-31 11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 12 AD-01 12 EXPANSION JOINT, REFER TO SHEET AD-33 2-HR RATED FIRE BARRIER STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF CONCRETE SLAB ABOVE. 1314 DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB N
City Council 23 – 9512/6/2022 1 4.4 5.2 6.2 7.2 8.2 8.5 10.3 11 12 13
LL.6
L P.5R
T
R
TH.8
P
P
N
N
Q
Q
S
S 8.7 9.6 9.7 10.110.2 Q.1 Q.2 P.7
2 2.1 11.2 11.511.7
M R.5 S.4 P.4 P.2 P.3 P.6 N.1 N.4 N.2 N.3
MM.1 M.2 M.4 M.3 244'-6" 4'-5" 2'-5" 24'-5 1/2" 27'-7 1/2" 30'-1" 30'-4" 30'-4" 16'-3 1/2" 31'-11 1/2" 14'-1" 27'-0" 5'-6" 16'-8 5/8" 13'-9" 4'-5" 17'-9 1/2" 2'-7 1/2" 3'-9" 1'-4" 2'-0 1/2" 3'-7 1/2" 12'-2 1/2" 5'-4 7/8" 5'-9 1/8" 108'-10"
9'-1" 8'-2 1/2" 22'-3 1/2" 21'-7 1/4" 18'-7 1/2" 9'-2 3/4" 7'-2 3/4"
2'-11 3/4"
9" 11'-4" 6'-3" 8'-3 1/4" 1'-7 3/4" 4'-6"
116'-5 7/8"
9'-1 1/8" 8'-2 1/2" 19'-9 1/2" 22'-3 1/2" 21'-7 1/4" 18'-7 1/2" 9'-2 3/4" 5'-8 5/8"3'-4 1/2" 3'-10 1/2" 1'-2 3/4" 9" 2'-10 1/2" 1'-1 1/4"11'-1 3/4" 2'-6 1/2" 1'-0" 1'-3 3/4" 2 3/4"
9'-0 3/4" 7'-7 3/4" 4.8 5.5
19'-9 1/2" LV ELEC RETAIL RESTAURANT KITCHEN/ STORAGE PUBLIC LOBBY
LV ELEC
LV
ELEC
LV
ELEC CORRIDOR VENTILATION SHAFT (2) FUTURE GREASE SHAFTS ABOVE CORRIDOR VENTILATION SHAFT UP UP UP UP UP TURN-AROUND SPOT TRASH / LOADING VAN BIKE FIRE PUMP ROOM BOOSTER PUMP ROOM STAIR A1 STAIR A2 TURN AROUND SPOT VAN VAN 3.2 3.4
4 5 5.1
6 7
8 8.8
9 10
BAC.2C
D
E
FG
H
KJ.5 G.9 G.7
3 4.3 8.9 185'-4" 16'-4" 31'-6" 28'-6" 31'-6" 30'-0" 31'-6" 16'-0" 1'-5" 3'-8" 11'-3" 2'-9" 1'-3" 2'-8" 1'-6" 123'-4"
13'-3" 30'-0" 13'-6" 4'-0" 13'-4" 30'-2" 14'-8" 1'-8"
2'-9" 2'-3"3'-10" 9"
J
2'-9"
2'-0" 6.1 UP 5% 123.44' 123.44' 123.44' 123.44' 124.04' 124.04' 124.04' 124.04' 127.04' 127.04' 127.04' 127.04' 127.04' 128.58' 128.58' 128.58' 128.58' 127.04' 128.58' 128.58' 124.70' 123.87' 123.14' 124.90' 124.90' 124.47' 125.07' 124.57' 124.72' 125.02' 124.49' 123.87' 124.52' 126.56' 127.36' 124.90' UP 5% UP 2% UP 5%
EV EV EV DN 4.5%
FEC
FEC FEC
ñ
ñ
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ PARCEL ROOM STAIR A4 STAIR A3
LV
ELEC ELEV A1 ELEV A2 IDF CORRIDOR VENTILATION SHAFT UP
DN 2.2% UP UP UP MPOE DN 4.5% 1.8% DN DN
1.8% DN 1.5%DN 4.5% DN
4.5% DN
1.3% DN 1.5% DN
4.5% TV
TRASH RECY REF SP SP
W R F
FEC
FEC
FEC
ELEC UP FITNESS LEASING OFFICE TRASH VESTIBULE
1 A2-21
2 A2-20
2 A2-21
A A2-40B A2-40
E A2-42
D A2-41
C A2-41
F A2-42
GA2-43
1 A2-20 123.21' 123.00' TSS 123.21' TSS 122.66' TSS 122.66' TSS 122.66' 123.65' 123.38' 123.30' 122.75' 122.75' 122.66' 122.66' 122.66' 123.50' 122.66' DN 4.5% DN 4.5% 124.17' 124.17' TSSDN 6.1% 124.17' 123.21' 124.80' 124.80' TSS 122.72' 122.66' 124.70' 124.68' 125.77' TSS 124.68' TSS 122.66' TSS 124.70' TSS 124.70' 124.05' 124.05' 123.38' 124.05' TSS 123.21' BUILDING A FIRST LEVEL SLAB PLAN FIRST LEVEL OVERALL SLAB PLAN SCALE: 1/16"=1'-0" 1 COPYRIGHT C A2-11S
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL FD FLOOR DRAIN KEYPLAN SLAB PLAN NOTES SYMBOL LEGEND DIRECTION OF SLOPE - 1/4" / FT U.N.O. CONCRETE SLAB ON GRADE OR ELEVATED CONCRETE SLAB DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE CONCRETE TOPPING SLAB. 4" DEPRESSION FROM TOP OF SLOPE (WHERE OCCURS), TYP. U.N.O. CONCRETE SLAB ON GRADE PER LANDSCAPE CONCRETE SLAB OVER STRUCTURAL FOAM - SEE STRUCTURAL FOR ADDITIONAL INFORMATION 1. TYPICAL DIMENSIONS ARE PROVIDED ON ARCHITECTURAL FLOORPLANS. ADDITIONAL DIMENSIONS ON SLAB PLAN ARE TO FACE OF CONCRETE, TYP, U.N.O. SEE "SLAB & FRAMING ALIGNMENT" DETAIL BELOW. 2. SEE CIVIL PLANS FOR FINISH SURFACE ELEVATIONS OF CONCRETE SLABS, TYP. 3. AT GARAGES, MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE - SEE FLOORPLANS. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. COORDINATE ALL UTILITIES, FIXTURES, SUPPORTS, ETC. ACCORDINGLY. 4. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. IT IS THE CONCRETE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ANY DISCREPANCY PRIOR TO THE POUR AND NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT FOR CORRECTIVE MEASURES. 5. PROVIDE CONCRETE BLOCKOUT AT TUB DRAINS. 6. PRIOR TO REQUESTING A FOUNDATION INSPECTION, GEOTECHNICAL CONSULTANT SHALL REVIEW AND APPROVE THE FOUNDATION EXCAVATIONS. 7. PROVIDE PENETRATION FIRESTOP SYSTEMS PER 8. AT DEPRESSED AREAS, SLOPES INIDCATED SHALL APPLY TO BOTH FINISH SURFACE AND CONCRETE SUBSTRATE, TYP. U.N.O. 9. PROVIDE VAPOR BARRIER BELOW ON-GRADE SLABS WHERE MOISTURE-SENSITIVE FLOOR COVERINGS OCCUR OR AS OTHERWISE RECOMMENDED BY GEOTECHNICAL ENGINEER - SEE GEOTECH REPORT. 10. ADDITIONAL EMBED PLATES MAY OCCUR - SEE STRUCTURAL AND LANDSCAPE DRAWINGS FOR LOCATIONS AND ADDITIONAL REQUIREMENTS. COORDINATE ANY DESIGN / BUILD ELEMENTS THAT MAY REQUIRE EMBED PLATES. 11. STRUCTURAL STEEL BASE PLATES AND FASTENERS ARE INTENDED TO SIT AT OR BELOW THE TOP OF CONCRETE SO AS NOT TO INTERUPT FINISH FLOORING. SEE STRUCTURAL DRAWINGS AND COORDINATE ASSOCIATED TRADES ACCORDINGLY. -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" CONCRETE STRUCTURAL SLAB TRANSITIONS SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB SLAB & FRAMING ALIGNMENT CONCRETE CURB OR STEM WALL, 8" MIN WIDTH, U.N.O. - SEE CIVIL AND STRL FOR ADDITIONAL INFORMATION
X AD-XX
X AD-XX FD 2 STAGE FLOOR DRAIN
X AD-XXX AD-XX -6" TOC DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE WATERPROOF TRAFFIC COATING. 1/2" DEPRESSION AT TOP OF SLOPE (WHERE OCCURS), TYP, U.N.O. DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE DECORATIVE PAVING PER LANDSCAPE. 6" DEPRESSION AT TOP OF SLOPE (WHERE OCCURS) U.N.O. TOOLED CONTROL JOINT IN CONCRETE TOPPING SLAB CONCRETE SLAB OPENINGX AD-XX X AD-XXX AD-XXX AD-XXX AD-XX ALIGN SUBSTRATES TO ALLOW FLUSH EXTERIOR FINISH. GC TO COORDINATE WITH ARCHITECT. EXTERIOR FINISH ALIGN EXTERIOR FINISH MULTIPLE LAYERS OF SHT'G AND/OR FURRING MAY OCCUR - SEE ARCH AND STRL PLANS IF SHT'G IS EXPOSED, PROTECT UNDERSIDE WITH GSM "Z" FLASHING OR SIMILAR APPROVED MATERIAL ALTERNATIVELY:PROVIDE SUITABLE FILL MATERIAL OR EXTEND CONCRETE SLAB TO ALIGN WITH EXTERIOR WALL SUBSTRATE. GC TO COORDINATE WITH ARCHITECT MULTIPLE LAYERS OF SHT'G AND/OR FURRING MAY OCCUR - SEE ARCH AND STRL PLANS TYP ELEVATED SLAB DIMENSION POINT PER FLOOR PLAN DIMENSION POINT PER FLOOR PLAN
B TYP SLAB ON GRADE
A WALL ASSEMBLY PER PLAN WALL ASSEMBLY PER PLAN
N
City Council 23 – 9612/6/2022
LV ELEC
1 201 4.4 5.2 6.2 7.2 8.2 8.5 10.3 11 12 13
LL.6
L P.5R
T
R
TH.8
P
P
N
N
Q
Q
S
S 8.7 9.6 9.7 10.110.2 Q.1 Q.2 P.7
2 2.1 11.2 11.511.7
M R.5 S.4 P.4 P.2 P.3 P.6 N.1 N.4 N.2 N.3
MM.1 M.2 M.4 M.3 244'-6" 4'-5" 2'-5" 24'-5 1/2" 27'-7 1/2" 30'-1" 30'-4" 30'-4" 16'-3 1/2" 31'-11 1/2" 14'-1" 27'-0" 5'-6" 16'-8 5/8" 13'-9" 4'-5" 17'-9 1/2" 2'-7 1/2" 3'-9" 1'-4" 2'-0 1/2" 3'-7 1/2" 12'-2 1/2" 5'-4 7/8" 5'-9 1/8" 108'-10"
9'-1" 8'-2 1/2" 22'-3 1/2" 21'-7 1/4" 18'-7 1/2" 9'-2 3/4" 7'-2 3/4"
2'-11 3/4"
9" 11'-4" 6'-3" 8'-3 1/4" 1'-7 3/4" 4'-6"
116'-5 7/8"
9'-1 1/8" 8'-2 1/2" 19'-9 1/2" 22'-3 1/2" 21'-7 1/4" 18'-7 1/2" 9'-2 3/4" 5'-8 5/8"3'-4 1/2" 3'-10 1/2" 1'-2 3/4" 9" 2'-10 1/2" 1'-1 1/4"11'-1 3/4" 2'-6 1/2" 1'-0" 1'-3 3/4" 2 3/4"
9'-0 3/4" 7'-7 3/4" 4.8 5.5
19'-9 1/2" STORAGE
LV ELEC
LV
ELEC
LV
ELEC
LV
ELEC LV ELEC
ELEC
ELEC
VAN OPEN TO BELOW 3.2 3.4
4 5 5.1
6 7
8 8.8
9 10
BAC.2C
D
E
FG
H
KJ.5 G.9 G.7
3 4.3 8.9 185'-4" 16'-4" 31'-6" 28'-6" 31'-6" 30'-0" 31'-6" 16'-0" 1'-5" 3'-8" 11'-3" 2'-9" 1'-3" 2'-8" 1'-6" 123'-4"
13'-3" 30'-0" 13'-6" 4'-0" 13'-4" 30'-2" 14'-8" 1'-8"
2'-9" 2'-3"3'-10" 9"
J
2'-9"
2'-0" 6.1 STAIR A1 UP 5%
UP 5% UP 5%
UP 4.3% DOWN 5% 133.08' 134.42' 134.42' 138.92' 138.92' 138.92' 138.92' 138.92' 140.00' 140.00' 140.00' 140.00' 140.00' 133.08' 133.08' 133.08' 133.08' 133.28' 134.42' 134.42' 134.42' 134.42' 133.08' 133.08' 138.92' 140.00' 139.62' 140.00' 138.67' 132.85' 133.96'
EV EV EV EV EV EV EV UP DN UP
FEC
FEC FECFEC
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ CORRIDOR VENTILATION SHAFT (2) FUTURE GREASE SHAFTS ABOVE CORRIDOR VENTILATION SHAFT STAIR A4 STAIR A3 ELEV A2 G R W STAIR A2 ELEV A1IDF CORRIDOR VENTILATION SHAFT DN UP DNUP IDF DN UP
SHELVING RETAIL/RESTUARANT UTILITY CLOSET POOL EQUIPMENT STORAGE MAINTENANCE SHARED GOODS COMMON OPS BREAK ROOM SPSP
FEC
FEC
FEC DN
4.5% YOGA STUDIO YOGA STORAGE WOMENS RESTROOM MENS RESTROOM OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW UNIT 0.3B A201 A5-03 1 A2-21
2 A2-20
1 A2-20
2 A2-21 UNIT 4.1B-R A202 A5-41UNIT 2.1B A203 A5-21 UNIT 2.1E-R A204 A5-22 UNIT 4.1F A206 A5-42 UNIT 3.2B A208 A5-32 UNIT 0.1A-R A205 A5-01 UNIT 0.1C A207 A5-01 66666
6 6 6 6 6 6 6
A A2-40B A2-40
E A2-42
D A2-41
C A2-41
2 A5-74
2 A5-76
2 A5-72 2 A5-70
2 A5-90
2 A5-94
1 A5-55
1 A5-51
1 A5-53
1'-0" 50'-5" 16'-5 1/2" 25'-0" 7'-6" 7'-2 1/2" 2'-5" 1'-0" 10'-3" 1'-0 3/4" 126'-7"
9" 53'-2" 36'-2" 6" 36'-0"
18'-4" 52'-8 3/4"
18'-4" 43'-0 1/2" 2"
2" 1'-0" A201 A202 A203 A204 A205 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A206 A207 A208 A209 A210 A211 A212 A213 A214 A215 A216 A217A218 A219 A220 A221 A222 A223 13 13 14 9 9 4'-5"
3'-0"
9'-0" TYP 18'-0" TYP.
24'-0" MIN. DRIVE AISLE
F A2-42
GA2-43 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A SECOND LEVEL FLOOR PLAN A2-12 BUILDING COMPOSITE PLAN NOTES 6 AD-31 1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. 2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE LEGAL ADDRESS. 3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE 4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. 6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON 7. THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY 8. WITH CBC 803. 9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. 10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATED ACCESS PANELS WITH SELF CLOSING DEVICES. 11. PROVIDE ACOUSTICAL ASSEMBLIES PER 12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. 13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER 14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. 15. SEE STRUCTURAL DRAWINGS FOR: A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING B) SPECIAL NAILING AND BLOCKING REQUIREMENTS 15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE VENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER PROTECTION SHALL BE EXTENDED TO THOSE AREAS. 16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED AND APPROVED. 17. PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTION THROUGHOUT. 18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) 19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE PROTECTION PER 20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FOR SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. 21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR SECURITY AND SAFETY. 22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. - AD-XX ALL AD-02.1 ALL AD-01 TO KEYNOTES MECHANICAL SHAFT - SEE MECHANICAL DWGS LINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF, SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH LOCAL FIRE AUTHORITY. BUILDING PLAN LEGEND DOOR SYMBOL FLOOR DRAIN - SEE PLMB XX WINDOW & STOREFRONT SYMBOL - A7-20
- A7-40 X FEC AD-XX DS DOWNSPOUT
X AD-XX WATERPROOF TRAFFIC COATING FD DIRECTION OF SLOPE - 1/4" / FT U.N.O.
X AD-XX 3-HR RATED FIRE WALL CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) ALL AD-20 18 AD-22 12 - A7-10
- A7-30 ACCESSIBLE PARKING SPACE
X AD-XXX AD-XX WATERPROOF TRAFFIC COATING FRAMED WALL - 6" METAL STUD CONCRETE COLUMN MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. FULL HEIGHT STEEL FENCING -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" 16 AD-31 40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEX AD-XX FRAMED WALL - 3-5/8" METAL STUD AIRCRAFT CABLE VEHICULAR BARRIER SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB -6" TOC X AD-XX CONCRETE WHEEL STOP DETECTABLE WARNINGS, MIN 36" WIDEX AD-XX CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) COLUMN CAP CMU WALL - SEE STRUCTURAL FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB CONCRETE WALL - SEE STRUCTURAL CONCRETE STRUCTURAL SLAB TRANSITIONS 3 RETAIL PARKING SPACE4 GUEST PARKING SPACE5 EV READY SPACE (FUTURE) 6 EV CHARGING SPACE (INSTALLED),REFER TO DETAIL 9/AD-31 7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR 10 3 AD-31 12 AD-31 11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 12 AD-01 12 EXPANSION JOINT, REFER TO SHEET AD-33 2-HR RATED FIRE BARRIER STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF CONCRETE SLAB ABOVE. 1314 DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB BUILDING A SECOND FLOOR PLAN SCALE: 3/32"=1'-0" 1 N
City Council 23 – 9712/6/2022
LV ELEC
1 201 4.4 5.2 6.2 7.2 8.2 8.5 10.3 11 12 13
LL.6
L P.5R
T
R
TH.8
P
P
N
N
Q
Q
S
S 8.7 9.6 9.7 10.110.2 Q.1 Q.2 P.7
2 2.1 11.2 11.511.7
M R.5 S.4 P.4 P.2 P.3 P.6 N.1 N.4 N.2 N.3
MM.1 M.2 M.4 M.3 244'-6" 4'-5" 2'-5" 24'-5 1/2" 27'-7 1/2" 30'-1" 30'-4" 30'-4" 16'-3 1/2" 31'-11 1/2" 14'-1" 27'-0" 5'-6" 16'-8 5/8" 13'-9" 4'-5" 17'-9 1/2" 2'-7 1/2" 3'-9" 1'-4" 2'-0 1/2" 3'-7 1/2" 12'-2 1/2" 5'-4 7/8" 5'-9 1/8" 108'-10"
9'-1" 8'-2 1/2" 22'-3 1/2" 21'-7 1/4" 18'-7 1/2" 9'-2 3/4" 7'-2 3/4"
2'-11 3/4"
9" 11'-4" 6'-3" 8'-3 1/4" 1'-7 3/4" 4'-6"
116'-5 7/8"
9'-1 1/8" 8'-2 1/2" 19'-9 1/2" 22'-3 1/2" 21'-7 1/4" 18'-7 1/2" 9'-2 3/4" 5'-8 5/8"3'-4 1/2" 3'-10 1/2" 1'-2 3/4" 9" 2'-10 1/2" 1'-1 1/4"11'-1 3/4" 2'-6 1/2" 1'-0" 1'-3 3/4" 2 3/4"
9'-0 3/4" 7'-7 3/4" 4.8 5.5
19'-9 1/2" STORAGE
LV ELEC
LV
ELEC
LV
ELEC
LV
ELEC LV ELEC
ELEC
ELEC
VAN OPEN TO BELOW 3.2 3.4
4 5 5.1
6 7
8 8.8
9 10
BAC.2C
D
E
FG
H
KJ.5 G.9 G.7
3 4.3 8.9 185'-4" 16'-4" 31'-6" 28'-6" 31'-6" 30'-0" 31'-6" 16'-0" 1'-5" 3'-8" 11'-3" 2'-9" 1'-3" 2'-8" 1'-6" 123'-4"
13'-3" 30'-0" 13'-6" 4'-0" 13'-4" 30'-2" 14'-8" 1'-8"
2'-9" 2'-3"3'-10" 9"
J
2'-9"
2'-0" 6.1 STAIR A1 UP 5%
UP 5% UP 5%
UP 4.3% DOWN 5% 133.08' 134.42' 134.42' 138.92' 138.92' 138.92' 138.92' 138.92' 140.00' 140.00' 140.00' 140.00' 140.00' 133.08' 133.08' 133.08' 133.08' 133.28' 134.42' 134.42' 134.42' 134.42' 133.08' 133.08' 138.92' 140.00' 139.62' 140.00' 138.67' 132.85' 133.96'
EV EV EV EV EV EV EV UP DN UP
FEC
FEC FECFEC
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ CORRIDOR VENTILATION SHAFT (2) FUTURE GREASE SHAFTS ABOVE CORRIDOR VENTILATION SHAFT STAIR A4 STAIR A3 ELEV A2 G R W STAIR A2 ELEV A1IDF CORRIDOR VENTILATION SHAFT DN UP DNUP IDF DN UP
SHELVING RETAIL/RESTUARANT UTILITY CLOSET POOL EQUIPMENT STORAGE MAINTENANCE SHARED GOODS COMMON OPS BREAK ROOM SPSP
FEC
FEC
FEC DN
4.5% YOGA STUDIO YOGA STORAGE WOMENS RESTROOM MENS RESTROOM OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW OPEN TO BELOW UP UP UP 134.42' TSS UP DN VARIES VARIES VARIES VARIES 1 A2-21
2 A2-20
2 A2-21
A A2-40B A2-40
E A2-42
D A2-41
C A2-41
F A2-42
GA2-43
1 A2-20 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A SECOND LEVEL SLAB PLAN A2-12S FD FLOOR DRAIN KEYPLAN SLAB PLAN NOTES SYMBOL LEGEND DIRECTION OF SLOPE - 1/4" / FT U.N.O. CONCRETE SLAB ON GRADE OR ELEVATED CONCRETE SLAB DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE CONCRETE TOPPING SLAB. 4" DEPRESSION FROM TOP OF SLOPE (WHERE OCCURS), TYP. U.N.O. CONCRETE SLAB ON GRADE PER LANDSCAPE CONCRETE SLAB OVER STRUCTURAL FOAM - SEE STRUCTURAL FOR ADDITIONAL INFORMATION 1. TYPICAL DIMENSIONS ARE PROVIDED ON ARCHITECTURAL FLOORPLANS. ADDITIONAL DIMENSIONS ON SLAB PLAN ARE TO FACE OF CONCRETE, TYP, U.N.O. SEE "SLAB & FRAMING ALIGNMENT" DETAIL BELOW. 2. SEE CIVIL PLANS FOR FINISH SURFACE ELEVATIONS OF CONCRETE SLABS, TYP. 3. AT GARAGES, MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE - SEE FLOORPLANS. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. COORDINATE ALL UTILITIES, FIXTURES, SUPPORTS, ETC. ACCORDINGLY. 4. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. IT IS THE CONCRETE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ANY DISCREPANCY PRIOR TO THE POUR AND NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT FOR CORRECTIVE MEASURES. 5. PROVIDE CONCRETE BLOCKOUT AT TUB DRAINS. 6. PRIOR TO REQUESTING A FOUNDATION INSPECTION, GEOTECHNICAL CONSULTANT SHALL REVIEW AND APPROVE THE FOUNDATION EXCAVATIONS. 7. PROVIDE PENETRATION FIRESTOP SYSTEMS PER 8. AT DEPRESSED AREAS, SLOPES INIDCATED SHALL APPLY TO BOTH FINISH SURFACE AND CONCRETE SUBSTRATE, TYP. U.N.O. 9. PROVIDE VAPOR BARRIER BELOW ON-GRADE SLABS WHERE MOISTURE-SENSITIVE FLOOR COVERINGS OCCUR OR AS OTHERWISE RECOMMENDED BY GEOTECHNICAL ENGINEER - SEE GEOTECH REPORT. 10. ADDITIONAL EMBED PLATES MAY OCCUR - SEE STRUCTURAL AND LANDSCAPE DRAWINGS FOR LOCATIONS AND ADDITIONAL REQUIREMENTS. COORDINATE ANY DESIGN / BUILD ELEMENTS THAT MAY REQUIRE EMBED PLATES. 11. STRUCTURAL STEEL BASE PLATES AND FASTENERS ARE INTENDED TO SIT AT OR BELOW THE TOP OF CONCRETE SO AS NOT TO INTERUPT FINISH FLOORING. SEE STRUCTURAL DRAWINGS AND COORDINATE ASSOCIATED TRADES ACCORDINGLY. -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" CONCRETE STRUCTURAL SLAB TRANSITIONS SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB SLAB & FRAMING ALIGNMENT CONCRETE CURB OR STEM WALL, 8" MIN WIDTH, U.N.O. - SEE CIVIL AND STRL FOR ADDITIONAL INFORMATION
X AD-XX
X AD-XX FD 2 STAGE FLOOR DRAIN
X AD-XXX AD-XX -6" TOC DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE WATERPROOF TRAFFIC COATING. 1/2" DEPRESSION AT TOP OF SLOPE (WHERE OCCURS), TYP, U.N.O. DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE DECORATIVE PAVING PER LANDSCAPE. 6" DEPRESSION AT TOP OF SLOPE (WHERE OCCURS) U.N.O. TOOLED CONTROL JOINT IN CONCRETE TOPPING SLAB CONCRETE SLAB OPENINGX AD-XX X AD-XXX AD-XXX AD-XXX AD-XX ALIGN SUBSTRATES TO ALLOW FLUSH EXTERIOR FINISH. GC TO COORDINATE WITH ARCHITECT. EXTERIOR FINISH ALIGN EXTERIOR FINISH MULTIPLE LAYERS OF SHT'G AND/OR FURRING MAY OCCUR - SEE ARCH AND STRL PLANS IF SHT'G IS EXPOSED, PROTECT UNDERSIDE WITH GSM "Z" FLASHING OR SIMILAR APPROVED MATERIAL ALTERNATIVELY:PROVIDE SUITABLE FILL MATERIAL OR EXTEND CONCRETE SLAB TO ALIGN WITH EXTERIOR WALL SUBSTRATE. GC TO COORDINATE WITH ARCHITECT MULTIPLE LAYERS OF SHT'G AND/OR FURRING MAY OCCUR - SEE ARCH AND STRL PLANS TYP ELEVATED SLAB DIMENSION POINT PER FLOOR PLAN DIMENSION POINT PER FLOOR PLAN
B TYP SLAB ON GRADE
A WALL ASSEMBLY PER PLAN WALL ASSEMBLY PER PLAN
N
City Council 23 – 9812/6/2022 E E
D
D
D
E FUTURE REFER RACK, A/C LINES AND CONTROL LINES FOR RESTAURANT (2) FUTURE GREASE SHAFTS CORR VENT SHAFT ELEV A1 ELEV A2 IDF
G R W CORRIDOR VENTILATION SHAFT IDF IDF CORRIDOR VENTILATION SHAFT POOL RESTROOM EXHAUST SHAFT SP SP TRASH VESTIBULE
LV ELEC
LV
ELEC
LV
ELEC
LV ELEC
LV ELEC LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC UPDN UP 3.2 3.4
4 5 5.1
6 7
8 8.8
9 10
BAC.2C
D
E
FG
H
KJ.5 G.9 G.7
3 4.3 8.9 185'-4" 16'-4" 31'-6" 28'-6" 31'-6" 30'-0" 31'-6" 16'-0" 1'-5" 3'-8" 11'-3" 2'-9" 1'-3" 2'-8" 1'-6" 123'-4"
13'-3" 30'-0" 13'-6" 4'-0" 13'-4" 30'-2" 14'-8" 1'-8"
2'-9" 2'-3"3'-10" 9"
J
2'-9"
2'-0" 6.1 STAIR A1 144.50' 144.50' 144.50' 149.00' 149.00' 149.00' 149.00' 149.00' 150.06' 150.06' 150.06' 150.06' 150.06' 144.50' 144.50' 144.50' 144.50' 144.50' 144.50' 144.50' 149.00' 144.50' 149.00' 150.06' 150.06' 144.50' 149.68' 148.53' 144.23' 144.04' UP 5% UP 5.0% UP 5% DOWN 5% EV
EV EV EV
FEC
EV
FEC FEC FEC
DOWN 1.5%
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ STAIR A4 STAIR A3 STAIR A2 UP DN DNUP ELECTRICAL METERS ABOVE DN UP (2)WARMING D/W ICE REF U/C MICRO DRAWERS TRASHRECY FEC
FEC FEC
FEC 2% MIN. 9% MIN. 2% MIN. 2% MIN. 2% MIN. 4% MIN. 3.5% MIN. 3.5% MIN. 9% MIN. 9% MIN. 11% MIN. 3% MIN. 7% MIN. 3% MIN. 4.6% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3% MIN. 3% MIN. 4% MIN. 4% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 4% MIN. 4% MIN. 3% MIN. 3% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 5% MIN. 5% MIN. 3% MIN. 3% MIN. 3% MIN. 3% MIN. 5% MIN. 5% MIN. 4% MIN. 4% MIN. 3% MIN. 3% MIN. 3% MIN. 5% MIN. 5% MIN. 5% MIN. 5% MIN. 7% MIN. 7% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3% MIN. 3% MIN. 3% MIN. 3% MIN. 2% MIN. 4% MIN. 7% MIN. 2% MIN. DN DOWN 3.1% CLUBROOM MENS RESTROOM WOMENS RESTROOM POOL SHOWER UNIT 0.3B A301 A5-03 1 A2-21
2 A2-20
1 A2-20
2 A2-21 UNIT 4.1C-R A302 A5-42UNIT 2.1C A303 A5-21 UNIT 2.1F-R A304 A5-22 UNIT 4.1G A306 A5-43 UNIT 4.1J A315 A5-43 UNIT 0.1B-R A305 A5-01 UNIT 1.2A A307 A5-13 UNIT 1.1A-R A308 A5-11 UNIT 2.4A A309 A5-28 UNIT 2.2D A310 A5-24 UNIT 1.2A-R A311 A5-13 UNIT 2.5A A314 A5-29 UNIT 1.2A A312 A5-13 UNIT 0.1D A313 A5-01 UNIT 2.6A A316 A5-35 UNIT 2.2B-R A317 A5-23 66666
6 6
6 5 5 5 5 5 5
1 A2-22
2 A2-22
3 A2-22
A A2-40B A2-40
E A2-42
DA2-41
C A2-41
3 A5-74
3 A5-76
3 A5-72 2 A5-70
3 A5-90
3 A5-94
1 A5-60
1'-0"
18'-4" 2"
AIRSPACE
53'-0" 2"
AIRSPACE
37'-6" 1'-0" 10'-3" 2" AIRSPACE 16'-1 1/2" 2" AIRSPACE 25'-0" 18'-4" 53'-2" 2"
AIRSPACE
9'-6 1/4" 2"
AIRSPACE
35'-10" 1'-0 3/4" 36'-0" 36'-0" 2"
AIRSPACE
53'-2" 9"
110'-4 1/2" 243'-6" 34'-6" 2" AIRSPACE 37'-6" 91'-9 1/2" 37'-6" 2" AIRSPACE 33'-0" 7'-10 1/2" 34'-6" 2"
AIRSPACE
11'-3" 2"
AIRSPACE
24'-6" 6'-11" 2" 24'-11" 2'-1" 9'-9" 2" AIRSPACE 60'-0" 6" 23'-10" 2" AIRSPACE 25'-0" 6'-6" 4'-10"2" 22'-0" 8'-0" 7'-9 1/2" 9'-9 1/2" 2" 22'-0 1/2" 2" 4'-9 1/2" 6'-7" 25'-0" 34'-2" 2"
AIRSPACE
23'-10" 2"
AIRSPACE
11'-5" 6'-2" 6'-5 1/2" 2" 25'-8" 1'-4" 1'-0" 7'-3 1/2" 6" 24'-6" 2" 7'-4" 6" 9" 7'-6" 7'-2 1/2" 1'-5"
1'-2 1/2" 5" 91'-9 1/2" 9'-10" 2" 7'-2 1/2"2" 1'-3" 2" 10'-7" 5'-1" 2" 2'-3" 2" 4'-11" 1'-0" A301 A302 A303 A304 A305 A306 A307 A308 A309 A310 A311 A312 A313 A314 A315 A316 A317 A318 A319 A320 A321 A323 A322 F A2-42 GA2-43 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A THIRD LEVEL FLOOR PLAN BUILDING A THIRD LEVEL FLOOR PLAN SCALE: 3/32"=1'-0" 1 A2-13 BUILDING COMPOSITE PLAN NOTES
6 AD-31 1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. 2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE LEGAL ADDRESS. 3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE 4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. 6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON 7. THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY 8. WITH CBC 803. 9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. 10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATED ACCESS PANELS WITH SELF CLOSING DEVICES. 11. PROVIDE ACOUSTICAL ASSEMBLIES PER 12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. 13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER 14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. 15. SEE STRUCTURAL DRAWINGS FOR: A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING B) SPECIAL NAILING AND BLOCKING REQUIREMENTS 15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE VENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER PROTECTION SHALL BE EXTENDED TO THOSE AREAS. 16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED AND APPROVED. 17. PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTION THROUGHOUT. 18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) 19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE PROTECTION PER 20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FOR SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. 21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR SECURITY AND SAFETY. 22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. - AD-XX ALL AD-02.1 ALL AD-01 TO KEYNOTES MECHANICAL SHAFT - SEE MECHANICAL DWGS LINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF, SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH LOCAL FIRE AUTHORITY. BUILDING PLAN LEGEND DOOR SYMBOL FLOOR DRAIN - SEE PLMB XX WINDOW & STOREFRONT SYMBOL - A7-20
- A7-40 X FEC AD-XX DS DOWNSPOUT
X AD-XX WATERPROOF TRAFFIC COATING FD DIRECTION OF SLOPE - 1/4" / FT U.N.O.
X AD-XX 3-HR RATED FIRE WALL CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) ALL AD-20 18 AD-22 12 - A7-10
- A7-30 ACCESSIBLE PARKING SPACE
X AD-XXX AD-XX WATERPROOF TRAFFIC COATING FRAMED WALL - 6" METAL STUD CONCRETE COLUMN MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. FULL HEIGHT STEEL FENCING -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" 16 AD-31 40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEX AD-XX FRAMED WALL - 3-5/8" METAL STUD AIRCRAFT CABLE VEHICULAR BARRIER SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB -6" TOC X AD-XX CONCRETE WHEEL STOP DETECTABLE WARNINGS, MIN 36" WIDEX AD-XX CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) COLUMN CAP CMU WALL - SEE STRUCTURAL FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB CONCRETE WALL - SEE STRUCTURAL CONCRETE STRUCTURAL SLAB TRANSITIONS 3 RETAIL PARKING SPACE4 GUEST PARKING SPACE5 EV READY SPACE (FUTURE) 6 EV CHARGING SPACE (INSTALLED),REFER TO DETAIL 9/AD-31 7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR 10 3 AD-31 12 AD-31 11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 12 AD-01 12 EXPANSION JOINT, REFER TO SHEET AD-33 2-HR RATED FIRE BARRIER STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF CONCRETE SLAB ABOVE. 1314 DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB N
City Council 23 – 9912/6/2022 FUTURE REFER RACK, A/C LINES AND CONTROL LINES FOR RESTAURANT (2) FUTURE GREASE SHAFTS CORR VENT SHAFT ELEV A1 ELEV A2 IDF
G R W CORRIDOR VENTILATION SHAFT IDF IDF CORRIDOR VENTILATION SHAFT POOL RESTROOM EXHAUST SHAFT SP SP TRASH VESTIBULE
LV ELEC
LV
ELEC
LV
ELEC
LV ELEC
LV ELEC LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC UPDN UP 3.2 3.4
4 5 5.1
6 7
8 8.8
9 10
BAC.2C
D
E
FG
H
KJ.5 G.9 G.7
3 4.3 8.9 185'-4" 16'-4" 31'-6" 28'-6" 31'-6" 30'-0" 31'-6" 16'-0" 1'-5" 3'-8" 11'-3" 2'-9" 1'-3" 2'-8" 1'-6" 123'-4"
13'-3" 30'-0" 13'-6" 4'-0" 13'-4" 30'-2" 14'-8" 1'-8"
2'-9" 2'-3"3'-10" 9"
J
2'-9"
2'-0" 6.1 STAIR A1 144.50' 144.50' 144.50' 149.00' 149.00' 149.00' 149.00' 149.00' 150.06' 150.06' 150.06' 150.06' 150.06' 144.50' 144.50' 144.50' 144.50' 144.50' 144.50' 144.50' 149.00' 144.50' 149.00' 150.06' 150.06' 144.50' 149.68' 148.53' 144.23' 144.04' UP 5% UP 5.0% UP 5% DOWN 5% EV
EV EV EV
FEC
EV
FEC FEC FEC
DOWN 1.5%
ñ
ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ STAIR A4 STAIR A3 STAIR A2 UP DN DNUP ELECTRICAL METERS ABOVE DN UP 2% MIN. 9% MIN. 2% MIN. 2% MIN. 2% MIN. 4% MIN. 3.5% MIN. 3.5% MIN. 9% MIN. 9% MIN. 11% MIN. 3% MIN. 7% MIN. 3% MIN. 4.6% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3% MIN. 3% MIN. 4% MIN. 4% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 4% MIN. 4% MIN. 3% MIN. 3% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 3.5% MIN. 5% MIN. 5% MIN. 3% MIN. 3% MIN. 3% MIN. 3% MIN. 5% MIN. 5% MIN. 4% MIN. 4% MIN. 3% MIN. 3% MIN. 3% MIN. 5% MIN. 5% MIN. 5% MIN. 5% MIN. 7% MIN. 7% MIN. 2% MIN. 2% MIN. 2% MIN. 2% MIN. 3% MIN. 3% MIN. 3% MIN. 3% MIN. 2% MIN. 4% MIN. 7% MIN. 2% MIN. DN DOWN 3.1% CLUBROOM MENS RESTROOM WOMENS RESTROOM POOL SHOWER 134.42' TSS 1 A2-21
2 A2-20
2 A2-21
A A2-40B A2-40
E A2-42
D A2-41
C A2-41
F A2-42
GA2-43
1 A2-20 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A THIRD LEVEL SLAB PLAN A2-13S FD FLOOR DRAIN KEYPLAN SLAB PLAN NOTES SYMBOL LEGEND DIRECTION OF SLOPE - 1/4" / FT U.N.O. CONCRETE SLAB ON GRADE OR ELEVATED CONCRETE SLAB DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE CONCRETE TOPPING SLAB. 4" DEPRESSION FROM TOP OF SLOPE (WHERE OCCURS), TYP. U.N.O. CONCRETE SLAB ON GRADE PER LANDSCAPE CONCRETE SLAB OVER STRUCTURAL FOAM - SEE STRUCTURAL FOR ADDITIONAL INFORMATION 1. TYPICAL DIMENSIONS ARE PROVIDED ON ARCHITECTURAL FLOORPLANS. ADDITIONAL DIMENSIONS ON SLAB PLAN ARE TO FACE OF CONCRETE, TYP, U.N.O. SEE "SLAB & FRAMING ALIGNMENT" DETAIL BELOW. 2. SEE CIVIL PLANS FOR FINISH SURFACE ELEVATIONS OF CONCRETE SLABS, TYP. 3. AT GARAGES, MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE - SEE FLOORPLANS. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. COORDINATE ALL UTILITIES, FIXTURES, SUPPORTS, ETC. ACCORDINGLY. 4. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. IT IS THE CONCRETE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ANY DISCREPANCY PRIOR TO THE POUR AND NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT FOR CORRECTIVE MEASURES. 5. PROVIDE CONCRETE BLOCKOUT AT TUB DRAINS. 6. PRIOR TO REQUESTING A FOUNDATION INSPECTION, GEOTECHNICAL CONSULTANT SHALL REVIEW AND APPROVE THE FOUNDATION EXCAVATIONS. 7. PROVIDE PENETRATION FIRESTOP SYSTEMS PER 8. AT DEPRESSED AREAS, SLOPES INIDCATED SHALL APPLY TO BOTH FINISH SURFACE AND CONCRETE SUBSTRATE, TYP. U.N.O. 9. PROVIDE VAPOR BARRIER BELOW ON-GRADE SLABS WHERE MOISTURE-SENSITIVE FLOOR COVERINGS OCCUR OR AS OTHERWISE RECOMMENDED BY GEOTECHNICAL ENGINEER - SEE GEOTECH REPORT. 10. ADDITIONAL EMBED PLATES MAY OCCUR - SEE STRUCTURAL AND LANDSCAPE DRAWINGS FOR LOCATIONS AND ADDITIONAL REQUIREMENTS. COORDINATE ANY DESIGN / BUILD ELEMENTS THAT MAY REQUIRE EMBED PLATES. 11. STRUCTURAL STEEL BASE PLATES AND FASTENERS ARE INTENDED TO SIT AT OR BELOW THE TOP OF CONCRETE SO AS NOT TO INTERUPT FINISH FLOORING. SEE STRUCTURAL DRAWINGS AND COORDINATE ASSOCIATED TRADES ACCORDINGLY. -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" CONCRETE STRUCTURAL SLAB TRANSITIONS SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB SLAB & FRAMING ALIGNMENT CONCRETE CURB OR STEM WALL, 8" MIN WIDTH, U.N.O. - SEE CIVIL AND STRL FOR ADDITIONAL INFORMATION
X AD-XX
X AD-XX FD 2 STAGE FLOOR DRAIN
X AD-XXX AD-XX -6" TOC DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE WATERPROOF TRAFFIC COATING. 1/2" DEPRESSION AT TOP OF SLOPE (WHERE OCCURS), TYP, U.N.O. DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE DECORATIVE PAVING PER LANDSCAPE. 6" DEPRESSION AT TOP OF SLOPE (WHERE OCCURS) U.N.O. TOOLED CONTROL JOINT IN CONCRETE TOPPING SLAB CONCRETE SLAB OPENINGX AD-XX X AD-XXX AD-XXX AD-XXX AD-XX ALIGN SUBSTRATES TO ALLOW FLUSH EXTERIOR FINISH. GC TO COORDINATE WITH ARCHITECT. EXTERIOR FINISH ALIGN EXTERIOR FINISH MULTIPLE LAYERS OF SHT'G AND/OR FURRING MAY OCCUR - SEE ARCH AND STRL PLANS IF SHT'G IS EXPOSED, PROTECT UNDERSIDE WITH GSM "Z" FLASHING OR SIMILAR APPROVED MATERIAL ALTERNATIVELY:PROVIDE SUITABLE FILL MATERIAL OR EXTEND CONCRETE SLAB TO ALIGN WITH EXTERIOR WALL SUBSTRATE. GC TO COORDINATE WITH ARCHITECT MULTIPLE LAYERS OF SHT'G AND/OR FURRING MAY OCCUR - SEE ARCH AND STRL PLANS TYP ELEVATED SLAB DIMENSION POINT PER FLOOR PLAN DIMENSION POINT PER FLOOR PLAN
B TYP SLAB ON GRADE
A WALL ASSEMBLY PER PLAN WALL ASSEMBLY PER PLAN
N
City Council 23 – 10012/6/2022 FUTURE REFER RACK, A/C LINES AND CONTROL LINES FOR RESTAURANT (2) FUTURE GREASE SHAFTS CORR VENT SHAFT ELEV A1 ELEV A2 IDF
G R W CORRIDOR VENTILATION SHAFT IDF IDF CORRIDOR VENTILATION SHAFT POOL RESTROOM EXHAUST SHAFT SP SP TRASH VESTIBULE
LV ELEC
LV
ELEC
LV
ELEC
LV ELEC
LV ELEC LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC DN UP 3.2 3.4
4 5 5.1
6 7
8 8.8
9 10
BAC.2C
D
E
FG
H
KJ.5 G.9 G.7
3 4.3 8.9 185'-4" 16'-4" 31'-6" 28'-6" 31'-6" 30'-0" 31'-6" 16'-0" 1'-5" 3'-8" 11'-3" 2'-9" 1'-3" 2'-8" 1'-6" 123'-4"
13'-3" 30'-0" 13'-6" 4'-0" 13'-4" 30'-2" 14'-8" 1'-8"
2'-9" 2'-3"3'-10" 9"
J
2'-9"
2'-0" 6.1 STAIR A1 UP 5%
UP 5% UP 5% DOWN 5% 154.56' 154.56' 154.56' 159.06' 159.06' 159.06' 159.06' 159.06' 160.12' 160.12' 160.12' 160.12' 160.12' 154.56' 154.56' 154.56' 154.56' 154.56' 154.56' 154.56' 159.06' 154.56' 159.06' 160.12' 160.12' 154.56' 159.74' 158.59' 154.29' 154.10' FEC FEC FEC FEC DOWM 1.5%
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ LV
ELEC STAIR A4 STAIR A3 STAIR A2 UP DN DNUP HVAC SP
FEC
FEC FEC
FEC DN
3.1% UNIT 0.3B A401 A5-03
1 A2-21
2 A2-20
1 A2-20
2 A2-21 UNIT 4.1B-R A402 A5-41 UNIT 2.1B A403 A5-21 UNIT 2.1E-R A404 A5-22 UNIT 4.1H A406 A5-43 UNIT 4.1K A416 A5-43 UNIT 0.1B-R A405 A5-01 UNIT 1.2B A407 A5-13 UNIT 1.1D-R A408 A5-12 UNIT 2.4A A409 A5-28 UNIT 2.2D A410 A5-24 UNIT 1.2B-R A411 A5-13 UNIT 2.5B A415 A5-29 UNIT 1.2B A413 A5-13 UNIT 0.1D A414 A5-01 UNIT 2.2A-R A417 A5-35 UNIT 2.2B-R A418 A5-23 UNIT 1.1B-R A412 A5-11 55555
5 5 5 5 5 5 5 5 5 5 DN UP
A A2-40B A2-40
E A2-42
D A2-41
C A2-41
1 A2-22
2 A2-22
3 A2-22
3 A5-74
4 A5-76
3 A5-72 3 A5-70
3 A5-90
3 A5-94
2 A5-60
1'-0"
18'-4" 2"
AIRSPACE
53'-0" 2"
AIRSPACE
37'-6" 1'-0" 10'-3" 2" AIRSPACE 16'-1 1/2" 2" AIRSPACE 25'-0" 18'-4" 53'-2" 2"
AIRSPACE
9'-6 1/4" 2"
AIRSPACE
35'-10" 1'-0 3/4" 36'-0" 36'-0" 2"
AIRSPACE
53'-2" 9"
110'-4 1/2" 242'-6" 34'-6" 2" AIRSPACE 37'-6" 91'-9 1/2" 37'-6" 2" AIRSPACE 33'-0" 7'-10 1/2" 34'-6" 2"
AIRSPACE
11'-3" 2"
AIRSPACE
24'-6" 6'-11" 2" 24'-11" 2'-1" 9'-9" 2" AIRSPACE 60'-0" 6" 23'-10" 2" AIRSPACE 25'-0" 6'-6" 4'-10"2" 22'-0" 8'-0" 7'-9 1/2" 9'-9 1/2" 2" 22'-0 1/2" 2" 4'-9 1/2" 6'-7" 25'-0" 34'-2" 2"
AIRSPACE
23'-10" 2"
AIRSPACE
11'-5" 6'-2" 6'-5 1/2" 2" 25'-8" 1'-4" 1'-0" 7'-3 1/2" 6" 24'-6" 2" 7'-4" 6" 9" 7'-6" 7'-2 1/2" 1'-5"
1'-2 1/2" 5" 91'-9 1/2" 9'-10" 2" 7'-2 1/2"2" 1'-3" 2" 10'-7" 5'-1" 2" 2'-3" 2" 4'-11" A401 A402 A403 A404 A405 A406 A407 A408 A409 A410 A411 A412 A413 A414 A415 A41625'-0" 8'-11" 12'-4" 2" 32'-3" 2" 6'-4" 4'-8 1/2" 24'-6 1/4" 8'-3" 16'-2 1/4" 6" 23'-10" 2" 32'-3" 2" F A2-42
GA2-43 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A FOURTH LEVEL FLOOR PLAN A2-14 BUILDING COMPOSITE PLAN NOTES 6 AD-31 1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. 2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE LEGAL ADDRESS. 3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE 4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. 6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON 7. THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY 8. WITH CBC 803. 9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. 10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATED ACCESS PANELS WITH SELF CLOSING DEVICES. 11. PROVIDE ACOUSTICAL ASSEMBLIES PER 12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. 13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER 14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. 15. SEE STRUCTURAL DRAWINGS FOR: A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING B) SPECIAL NAILING AND BLOCKING REQUIREMENTS 15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE VENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER PROTECTION SHALL BE EXTENDED TO THOSE AREAS. 16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED AND APPROVED. 17. PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTION THROUGHOUT. 18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) 19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE PROTECTION PER 20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FOR SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. 21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR SECURITY AND SAFETY. 22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. - AD-XX ALL AD-02.1 ALL AD-01 TO KEYNOTES MECHANICAL SHAFT - SEE MECHANICAL DWGS LINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF, SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH LOCAL FIRE AUTHORITY. BUILDING PLAN LEGEND DOOR SYMBOL FLOOR DRAIN - SEE PLMB XX WINDOW & STOREFRONT SYMBOL - A7-20
- A7-40 X FEC AD-XX DS DOWNSPOUT
X AD-XX WATERPROOF TRAFFIC COATING FD DIRECTION OF SLOPE - 1/4" / FT U.N.O.
X AD-XX 3-HR RATED FIRE WALL CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) ALL AD-20 18 AD-22 12 - A7-10
- A7-30 ACCESSIBLE PARKING SPACE
X AD-XXX AD-XX WATERPROOF TRAFFIC COATING FRAMED WALL - 6" METAL STUD CONCRETE COLUMN MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. FULL HEIGHT STEEL FENCING -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" 16 AD-31 40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEX AD-XX FRAMED WALL - 3-5/8" METAL STUD AIRCRAFT CABLE VEHICULAR BARRIER SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB -6" TOC X AD-XX CONCRETE WHEEL STOP DETECTABLE WARNINGS, MIN 36" WIDEX AD-XX CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) COLUMN CAP CMU WALL - SEE STRUCTURAL FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB CONCRETE WALL - SEE STRUCTURAL CONCRETE STRUCTURAL SLAB TRANSITIONS 3 RETAIL PARKING SPACE4 GUEST PARKING SPACE5 EV READY SPACE (FUTURE) 6 EV CHARGING SPACE (INSTALLED),REFER TO DETAIL 9/AD-31 7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR 10 3 AD-31 12 AD-31 11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 12 AD-01 12 EXPANSION JOINT, REFER TO SHEET AD-33 2-HR RATED FIRE BARRIER STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF CONCRETE SLAB ABOVE. 1314 DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB BUILDING A FOURTH LEVEL FLOOR PLAN SCALE: 3/32"=1'-0" 1 N
City Council 23 – 10112/6/2022 FUTURE REFER RACK, A/C LINES AND CONTROL LINES FOR RESTAURANT (2) FUTURE GREASE SHAFTS CORR VENT SHAFT ELEV A1 ELEV A2 IDF
G R W CORRIDOR VENTILATION SHAFT IDF IDF CORRIDOR VENTILATION SHAFT POOL RESTROOM EXHAUST SHAFT SP SP TRASH VESTIBULE
LV ELEC
LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC 3.2 3.4
4 5 5.1
6 7
8 8.8
9 10
BAC.2C
D
E
FG
H
KJ.5 G.9 G.7
3 4.3 8.9 185'-4" 16'-4" 31'-6" 28'-6" 31'-6" 30'-0" 31'-6" 16'-0" 1'-5" 3'-8" 11'-3" 2'-9" 1'-3" 2'-8" 1'-6" 123'-4"
13'-3" 30'-0" 13'-6" 4'-0" 13'-4" 30'-2" 14'-8" 1'-8"
2'-9" 2'-3"3'-10" 9"
J
2'-9"
2'-0" 6.1TURN- AROUND SPOT
UP 5% UP 5% DOWN 5%
FEC
DOWN 1.6%
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ STAIR A4 STAIR A3 LV ELEC UP DN DN DNUP ELECTRICAL METERS
LV ELEC
LV
ELEC
LV
ELEC
FEC
FEC FEC DN
DOWN 4.5%
FEC UNIT 0.3C A501 A5-03
1 A2-21
2 A2-20
1 A2-20
2 A2-21 UNIT 4.1C-R A502 A5-42UNIT 2.1C A503 A5-21 UNIT 2.1F-R A504 A5-22 UNIT 4.1H A506 A5-43 UNIT 4.1K A518 A5-43 UNIT 0.1B-R A505 A5-01 UNIT 1.2B A507 A5-13 UNIT 1.1D-R A508 A5-12 UNIT 2.4B A509 A5-28 UNIT 2.2E A510 A5-24 UNIT 1.2B-R A511 A5-13 UNIT 2.5B A517 A5-29 UNIT 1.2B A515 A5-13 UNIT 0.1D A516 A5-01 UNIT 2.6A A519 A5-35 UNIT 2.2C-R A520 A5-24 UNIT 1.1B-R A512 A5-11 UNIT 1.1C A513 A5-11 UNIT 2.1G-R A514 A5-22 A A2-40B A2-40
E A2-42
D A2-41
C A2-41
1 A2-22
2 A2-22
3 A2-22
1'-0"
18'-4" 2"
AIRSPACE
53'-0" 2"
AIRSPACE
37'-6" 1'-0" 10'-3" 2" AIRSPACE 16'-1 1/2" 2" AIRSPACE 25'-0" 18'-4" 53'-2" 2"
AIRSPACE
9'-6 1/4" 2"
AIRSPACE
35'-10" 1'-0 3/4" 36'-0" 36'-0" 2"
AIRSPACE
53'-2" 9"
110'-4 1/2" 242'-6" 34'-6" 2" AIRSPACE 37'-6" 91'-9 1/2" 37'-6" 2" AIRSPACE 33'-0" 7'-10 1/2" 3 A5-74
4 A5-76
4 A5-72
3 A5-90
3 A5-94
34'-6" 2"
AIRSPACE
11'-3" 2"
AIRSPACE
24'-6" 6'-11" 2" 24'-11" 2'-1" 9'-9" 2" AIRSPACE 36'-0" 2" AIRSPACE 23'-10" 6" 23'-10" 2" AIRSPACE 25'-0" 6'-6" 4'-10"2" 22'-0" 8'-0" 7'-9 1/2" 9'-9 1/2" 2" 22'-0 1/2" 2" 4'-9 1/2" 6'-7" 25'-0" 34'-2" 2"
AIRSPACE
23'-10" 2"
AIRSPACE
11'-5" 6'-2" 6'-5 1/2" 2" 25'-8" 1'-4" 1'-0" 7'-3 1/2" 6" 24'-6" 2" 7'-4" 6" 9" 7'-6" 7'-2 1/2" 1'-5"
1'-2 1/2" 5" 91'-9 1/2" 9'-10" 2" 7'-2 1/2"2" 1'-3" 2" 10'-7" 5'-1" 2" 2'-3" 2" 4'-11" A501 A502 A503 A504 A505 A506 A507 A508 A509 A510 A511 A512 A513 A514 A515 A516 A517 F A2-42 GA2-43 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A FIFTH LEVEL FLOOR PLAN A2-15 BUILDING COMPOSITE PLAN NOTES 6 AD-31 1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. 2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE LEGAL ADDRESS. 3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE 4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. 6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON 7. THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY 8. WITH CBC 803. 9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. 10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATED ACCESS PANELS WITH SELF CLOSING DEVICES. 11. PROVIDE ACOUSTICAL ASSEMBLIES PER 12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. 13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER 14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. 15. SEE STRUCTURAL DRAWINGS FOR: A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING B) SPECIAL NAILING AND BLOCKING REQUIREMENTS 15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE VENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER PROTECTION SHALL BE EXTENDED TO THOSE AREAS. 16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED AND APPROVED. 17. PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTION THROUGHOUT. 18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) 19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE PROTECTION PER 20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FOR SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. 21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR SECURITY AND SAFETY. 22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. - AD-XX ALL AD-02.1 ALL AD-01 TO KEYNOTES MECHANICAL SHAFT - SEE MECHANICAL DWGS LINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF, SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH LOCAL FIRE AUTHORITY. BUILDING PLAN LEGEND DOOR SYMBOL FLOOR DRAIN - SEE PLMB XX WINDOW & STOREFRONT SYMBOL - A7-20
- A7-40 X FEC AD-XX DS DOWNSPOUT
X AD-XX WATERPROOF TRAFFIC COATING FD DIRECTION OF SLOPE - 1/4" / FT U.N.O.
X AD-XX 3-HR RATED FIRE WALL CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) ALL AD-20 18 AD-22 12 - A7-10
- A7-30 ACCESSIBLE PARKING SPACE
X AD-XXX AD-XX WATERPROOF TRAFFIC COATING FRAMED WALL - 6" METAL STUD CONCRETE COLUMN MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. FULL HEIGHT STEEL FENCING -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" 16 AD-31 40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEX AD-XX FRAMED WALL - 3-5/8" METAL STUD AIRCRAFT CABLE VEHICULAR BARRIER SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB -6" TOC X AD-XX CONCRETE WHEEL STOP DETECTABLE WARNINGS, MIN 36" WIDEX AD-XX CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) COLUMN CAP CMU WALL - SEE STRUCTURAL FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB CONCRETE WALL - SEE STRUCTURAL CONCRETE STRUCTURAL SLAB TRANSITIONS 3 RETAIL PARKING SPACE4 GUEST PARKING SPACE5 EV READY SPACE (FUTURE) 6 EV CHARGING SPACE (INSTALLED),REFER TO DETAIL 9/AD-31 7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR 10 3 AD-31 12 AD-31 11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 12 AD-01 12 EXPANSION JOINT, REFER TO SHEET AD-33 2-HR RATED FIRE BARRIER STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF CONCRETE SLAB ABOVE. 1314 DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB BUILDING A FIFTH LEVEL FLOOR PLAN SCALE: 3/32"=1'-0" 1 N
City Council 23 – 10212/6/2022 FUTURE REFER RACK, A/C LINES AND CONTROL LINES FOR RESTAURANT (2) FUTURE GREASE SHAFTS CORR VENT SHAFT ELEV A1 ELEV A2 IDF
G R W CORRIDOR VENTILATION SHAFT IDF POOL RESTROOM EXHAUST SHAFT SP SP TRASH VESTIBULE
LV ELEC
LV ELEC
ELEC
LV
ELEC
LV
LV
ELEC LV ELEC LV ELEC LV
ELEC
LV ELEC
LV
ELEC LV ELEC LV ELEC
LV
ELEC LV
ELEC LV
ELEC LV ELEC STAIR A4 STAIR A3 TURN- AROUND SPOT
UP 5% UP 5% DOWN 5%
FEC
DOWN 1.6%
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ UP DN DNUP
FEC FEC FEC STORAGE
1 A2-21
2 A2-20
1 A2-20
2 A2-21 UNIT 4.1H A602 A5-43 UNIT 4.1K A614 A5-43 UNIT 0.1B-R A601 A5-01 UNIT 1.2B A603 A5-13 UNIT 1.1D-R A604 A5-12 UNIT 2.4A A605 A5-28 UNIT 2.2D A606 A5-24 UNIT 1.2B-R A607 A5-13 UNIT 2.5B A613 A5-29 UNIT 1.2B A611 A5-13 UNIT 0.1D A612 A5-01 UNIT 2.6A A615 A5-35 UNIT 2.2B-R A616 A5-24 UNIT 1.1B-R A608 A5-11 UNIT 1.1E A609 A5-12 UNIT 2.1H-R A610 A5-22 A A2-40B A2-40
E A2-42
D A2-41
C A2-41
1 A2-22
2 A2-22
3 A2-22
3 A5-74
4 A5-76
4 A5-90
3 A5-94
1'-0"
18'-4" 2"
AIRSPACE
53'-0" 2"
AIRSPACE
37'-6"
18'-4" 53'-0" 2"
AIRSPACE
9'-6 1/4" 2"
AIRSPACE
35'-10" 1'-0 3/4"
110'-4 1/2" 242'-6" 34'-6" 2" AIRSPACE 37'-6" 91'-9 1/2" 37'-6" 2" AIRSPACE 33'-0" 7'-10 1/2" 34'-6" 2"
AIRSPACE
11'-3" 2"
AIRSPACE
24'-6" 6'-11" 2" 24'-11" 2'-1" 9'-9" 2" AIRSPACE 36'-0" 2" AIRSPACE 23'-10" 6" 23'-10" 2" AIRSPACE 25'-0" 6'-6" 4'-10"2" 22'-0" 8'-0" 7'-9 1/2" 9'-9 1/2" 2" 22'-0 1/2" 2" 4'-9 1/2" 6'-7" 25'-0" 34'-2" 2"
AIRSPACE
23'-10" 2"
AIRSPACE
11'-5" 6'-2" 6'-5 1/2" 2" 25'-8" 1'-4"
1'-2 1/2" 5" 91'-9 1/2" 9'-10" 2" 7'-2 1/2"2" 1'-3" 2" 10'-7" 5'-1" 2" 2'-3" 2" 4'-11" 2"
AIRSPACE A601 A602 A603 A604 A605 A606 A607 A608 A609 A610 F A2-42
GA2-43 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A SIXTH LEVEL FLOOR PLAN A2-16 BUILDING COMPOSITE PLAN NOTES 6 AD-31 1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. 2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE LEGAL ADDRESS. 3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE 4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. 6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON 7. THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY 8. WITH CBC 803. 9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. 10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATED ACCESS PANELS WITH SELF CLOSING DEVICES. 11. PROVIDE ACOUSTICAL ASSEMBLIES PER 12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. 13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER 14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. 15. SEE STRUCTURAL DRAWINGS FOR: A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING B) SPECIAL NAILING AND BLOCKING REQUIREMENTS 15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE VENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER PROTECTION SHALL BE EXTENDED TO THOSE AREAS. 16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED AND APPROVED. 17. PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTION THROUGHOUT. 18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) 19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE PROTECTION PER 20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FOR SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. 21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR SECURITY AND SAFETY. 22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. - AD-XX ALL AD-02.1 ALL AD-01 TO KEYNOTES MECHANICAL SHAFT - SEE MECHANICAL DWGS LINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF, SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH LOCAL FIRE AUTHORITY. BUILDING PLAN LEGEND DOOR SYMBOL FLOOR DRAIN - SEE PLMB XX WINDOW & STOREFRONT SYMBOL - A7-20
- A7-40 X FEC AD-XX DS DOWNSPOUT
X AD-XX WATERPROOF TRAFFIC COATING FD DIRECTION OF SLOPE - 1/4" / FT U.N.O.
X AD-XX 3-HR RATED FIRE WALL CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) ALL AD-20 18 AD-22 12 - A7-10
- A7-30 ACCESSIBLE PARKING SPACE
X AD-XXX AD-XX WATERPROOF TRAFFIC COATING FRAMED WALL - 6" METAL STUD CONCRETE COLUMN MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. FULL HEIGHT STEEL FENCING -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" 16 AD-31 40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEX AD-XX FRAMED WALL - 3-5/8" METAL STUD AIRCRAFT CABLE VEHICULAR BARRIER SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB -6" TOC X AD-XX CONCRETE WHEEL STOP DETECTABLE WARNINGS, MIN 36" WIDEX AD-XX CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) COLUMN CAP CMU WALL - SEE STRUCTURAL FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB CONCRETE WALL - SEE STRUCTURAL CONCRETE STRUCTURAL SLAB TRANSITIONS 3 RETAIL PARKING SPACE4 GUEST PARKING SPACE5 EV READY SPACE (FUTURE) 6 EV CHARGING SPACE (INSTALLED),REFER TO DETAIL 9/AD-31 7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR 10 3 AD-31 12 AD-31 11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 12 AD-01 12 EXPANSION JOINT, REFER TO SHEET AD-33 2-HR RATED FIRE BARRIER STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF CONCRETE SLAB ABOVE. 1314 DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB BUILDING A SIXTH LEVEL FLOOR PLAN SCALE: 3/32"=1'-0" 1 N
City Council 23 – 10312/6/2022 FUTURE REFER RACK, A/C LINES AND CONTROL LINES FOR RESTAURANT (2) FUTURE GREASE SHAFTS CORR VENT SHAFT ELEV A1 ELEV A2 IDF
G R W CORRIDOR VENTILATION SHAFT IDF POOL RESTROOM EXHAUST SHAFT SP SP TRASH VESTIBULE
LV ELEC
ELEC
LV LV ELEC LV ELEC LV
ELEC
LV ELEC
LV ELEC LV
ELEC LV
ELEC LV ELEC STAIR A4 STAIR A3 LV ELEC LV ELEC
LV
ELEC DN DN ELEVATOR MACHINE ROOM
LV ELEC SP
FEC FEC FEC
1 A2-21
2 A2-20
1 A2-20
2 A2-21 UNIT 4.1H A702 A7-43 UNIT 4.1E A713 A7-43 UNIT 0.1B-R A701 A7-01 UNIT 1.2B A703 A7-13 UNIT 1.1D-R A704 A7-12 UNIT 2.4B A705 A7-28 UNIT 2.2E A706 A7-24 UNIT 1.2B-R A707 A7-13 UNIT 2.5B A712 A7-29 UNIT 1.2B A711 A7-13 UNIT 2.2F-R A714 A7-24 UNIT 1.1B-R A708 A7-11 UNIT 1.1E A709 A7-12 UNIT 2.1H-R A710 A7-22 TURN- AROUND SPOT UP 5% UP 5% DOWN 5%
FEC
DOWN 1.6%
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
A A2-40B A2-40
E A2-42
D A2-41
C A2-41
1 A2-22
2 A2-22
3 A2-22
3 A5-74
3 A5-76
3 A5-90
3 A5-94
1'-0"
18'-4" 2"
AIRSPACE
53'-0" 37'-8"
18'-4" 53'-2" 2"
AIRSPACE
9'-6 1/4" 2"
AIRSPACE
35'-10" 1'-0 3/4"
110'-4 1/2" 242'-6" 34'-6" 37'-8" 91'-9 1/2" 37'-6" 2" AIRSPACE 33'-0" 7'-10 1/2" 34'-6" 2"
AIRSPACE
11'-3" 2"
AIRSPACE
24'-6" 6'-11" 2" 24'-11" 2'-1" 9'-9" 2" AIRSPACE 36'-0" 2" AIRSPACE 23'-10" 6" 23'-10" 2" AIRSPACE 25'-0" 6'-6" 4'-10"2" 22'-0" 8'-0" 7'-9 1/2" 9'-9 1/2" 2" 22'-0 1/2" 2" 4'-9 1/2" 6'-7" 25'-0" 34'-2" 2"
AIRSPACE
23'-10" 2"
AIRSPACE
11'-5" 6'-2" 6'-5 1/2" 2" 25'-8" 1'-4" 1'-0" 7'-3 1/2" 6" 24'-6" 2" 7'-4" 1'-2 1/2" 5" 91'-9 1/2" 9'-10" 2" 7'-2 1/2"2" 1'-3" 2" 10'-7" 5'-3" 2'-5" 4'-11" ROOF DECK A5-63 A701 A702 A703 A704 A705 A706 A707 A708 A709 A710 A711 A712 F A2-42
GA2-43 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A SEVENTH LEVEL FLOOR PLAN A2-17 BUILDING COMPOSITE PLAN NOTES 6 AD-31 1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. 2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE LEGAL ADDRESS. 3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE 4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. 6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON 7. THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY 8. WITH CBC 803. 9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. 10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATED ACCESS PANELS WITH SELF CLOSING DEVICES. 11. PROVIDE ACOUSTICAL ASSEMBLIES PER 12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. 13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER 14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. 15. SEE STRUCTURAL DRAWINGS FOR: A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING B) SPECIAL NAILING AND BLOCKING REQUIREMENTS 15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE VENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER PROTECTION SHALL BE EXTENDED TO THOSE AREAS. 16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED AND APPROVED. 17. PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTION THROUGHOUT. 18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) 19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE PROTECTION PER 20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FOR SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. 21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR SECURITY AND SAFETY. 22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. - AD-XX ALL AD-02.1 ALL AD-01 TO KEYNOTES MECHANICAL SHAFT - SEE MECHANICAL DWGS LINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF, SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH LOCAL FIRE AUTHORITY. BUILDING PLAN LEGEND DOOR SYMBOL FLOOR DRAIN - SEE PLMB XX WINDOW & STOREFRONT SYMBOL - A7-20
- A7-40 X FEC AD-XX DS DOWNSPOUT
X AD-XX WATERPROOF TRAFFIC COATING FD DIRECTION OF SLOPE - 1/4" / FT U.N.O.
X AD-XX 3-HR RATED FIRE WALL CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) ALL AD-20 18 AD-22 12 - A7-10
- A7-30 ACCESSIBLE PARKING SPACE
X AD-XXX AD-XX WATERPROOF TRAFFIC COATING FRAMED WALL - 6" METAL STUD CONCRETE COLUMN MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. FULL HEIGHT STEEL FENCING -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" 16 AD-31 40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEX AD-XX FRAMED WALL - 3-5/8" METAL STUD AIRCRAFT CABLE VEHICULAR BARRIER SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB -6" TOC X AD-XX CONCRETE WHEEL STOP DETECTABLE WARNINGS, MIN 36" WIDEX AD-XX CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) COLUMN CAP CMU WALL - SEE STRUCTURAL FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB CONCRETE WALL - SEE STRUCTURAL CONCRETE STRUCTURAL SLAB TRANSITIONS 3 RETAIL PARKING SPACE4 GUEST PARKING SPACE5 EV READY SPACE (FUTURE) 6 EV CHARGING SPACE (INSTALLED),REFER TO DETAIL 9/AD-31 7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR 10 3 AD-31 12 AD-31 11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 12 AD-01 12 EXPANSION JOINT, REFER TO SHEET AD-33 2-HR RATED FIRE BARRIER STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF CONCRETE SLAB ABOVE. 1314 DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB BUILDING A SEVENTH LEVEL FLOOR PLAN SCALE: 3/32"=1'-0" 1 N
City Council 23 – 10412/6/2022
LV ELEC DN
LV ELEC
LV
ELEC
LV
ELEC
FEC DN
DOWN 4.5%
G R W SP SP
LV ELEC
ELEC
LV LV ELEC LV ELEC LV
ELEC
LV ELEC
LV ELEC LV
ELEC LV
ELEC LV ELEC LV ELEC LV ELEC
LV
ELEC DN DN
LV ELEC SP
FEC FEC FEC TURN- AROUND SPOT
UP 5% UP 5% DOWN 5%
FEC
DOWN 1.6%
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ LV ELEC DN
LV ELEC
LV
ELEC
LV
ELEC
FEC DN
DOWN 4.5% 12 24 12 12
1 A2-21
2 A2-20
1 A2-20
2 A2-21
A A2-40B A2-40
E A2-42
DA2-41
C A2-41
1 A2-22
2 A2-22
3 A2-22
F A2-42
GA2-43 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A ROOF PLAN A2-18 MECHANICAL SHAFT - SEE MECHANICAL ROOFTOP GAS BOILER LOCATION - SEE PLUMBING ROOF HATCH WITH ALTERNATING TREAD DEVICE FROM STAIR SHAFT TRASH CHUTES EQUIPMENT PLATFORM CANOPY BELOW LINE OF BLDG BELOW ROOF PLAN NOTES KEYNOTES KEYPLAN 1. TYPICAL ROOFING DETAILS ARE INTENDED TO SHOW GENERAL DESIGN INTENT AND SHOULD BE VERIFIED AGAINST MANUFACTURER'S RECOMMENDATIONS & REQUIREMENTS FOR EACH CONDITION. SEE SHEETS 2. ROOF INSULATION SHALL FILL MAIN ROOF FRAMING CAVITIES AND ALL CAVITIES OF ROOF CRICKET FRAMING. 3. PER CBC SECTION 718.4. EXCEPTION , DRAFTSTOPPING IS NOT REQUIRED IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13. 4. ATTIC ACCESS NOT REQUIRED WHERE VERTICAL HEIGHT IN ATTIC IS LESS THAN 30". 5. VERIFY SIZE AND LOCATION OF ALL ROOF PENETRATIONS AND EQUIPMENT WITH STRUCTURAL, MECHANICAL AND PLUMBING DWGS. 6. AS REQUIRED BY CBC SEC. 1015.6 : 42" MIN. GUARDS SHALL BE PROVIDED WHERE APPLIANCES, EQUIPMENT, FANS, ROOF HATCHES OR OTHER COMPONENTS THAT REQUIRE SERVICE ARE LOCATED WITHIN 10 FEET OF A ROOF EDGE OR OPEN EDGE OR OPEN SIDE OF A WALKING SURFACE AND SUCH EDGE OR OPEN SIDE IS LOCATED MORE THAN 30 INCHES ABOVE THE FLOOR, ROOF OR GRADE BELOW. THE GUARD SHALL BE CONSTRUCTED SO AS TO PREVENT THE PASSAGE OF A SPHERE 21 INCHES IN DIAMETER. 7. ROOFING TO BE CLASS 'A' ROOFING. 8. ROOF TRUSS DEPTH ASSUMED TO BE 24" MIN. VERIFY WITH TRUSS DESIGNER. 9. PENETRATIONS SHALL BE 18" MIN. FROM VALLEYS, HIPS, RIDGES OR PARAPETS UNLESS APPROVED BY ROOFING MANUFACTURER. 10. PARAPETS AND TALL ROOF WALLS MAY REQUIRE BRACING- REFER TO STRL DRAWINGS AND COORDINATE WITH TRUSS DESIGNER. 11. SEE EXTERIOR BUILDING MAINTENANCE PLANS FOR ADDITIONAL INFORMATION. - AD-61.1 DESCRIPTION ROOF ASSEMBLIES FIRE RATING DETAIL REFERENCE(S) ROOF CONSTRUCTION & ASSOCIATED SECONDARY MEMBERS INTERIOR ROOF/CEILING (TRUSSES) EXTERIOR ROOF/CEILING (TRUSSES) INTERIOR ROOF CEILING (JOISTS) EXTERIOR ROOF/CEILING (JOISTS) 1 HR 1 HR 1 HR 1 HR X/AD-XX, X/AD-XX X/AD-XX, X/AD-XX X/AD-XX, X/AD-XX X/AD-XX, X/AD-XX - AD-61.0 TO SLOPE ROOF 1/2" PER FOOT MIN ROOF PRIMARY AND OVERFLOW DRAIN BUILT-UP CRICKET 1/4" PER FOOT MIN FIRE WALL - EXTENDS TO UNDERSIDE OF ROOF SHEATHING, TYP U.N.O. HATCHED AREA INDICATES NO ROOF PENETRATIONS ALLOWED WITHIN 4'-0" OF THE FIRE WALL ROOF MEMBRANE WALKING PAD. 30" WIDE. SECURE TO ROOFING PER MANUFACTURER'S RECOMMENDATIONS. SOLAR-READY NOTES A/C CONDENSER - SEE MECHANICAL EXTERIOR BUILDING MAITENANCE EQUIPMENT AND ANCHORS - REFER TO STRL & EXTERIOR BUILDING MAINTENANCE DRAWINGS. COORDINATE WITH TRUSS DESIGN ROOF HATCH WITH SAFETY RAILING SYSTEM HIGH AND/OR LOW VENTS (FLAT ROOF): 24"X24" R.O. GRAVITY VENT BY FLASHCO OR APPROVED EQUAL WITH 520 S.I. NET FREE VENTILATION AREA PER VENT. HIGH VENTS (FLAT ROOF PARAPET): 14"x18" "FLASHVENT" PARAPET WALL VENTS BY FLASHCO OR APPROVED EQUAL WITH 110 S.I. NET FREE VENTILATION AREA PER VENT. LOW VENTS (SLOPED ROOF EAVES): FRIEZE BLOCK WITH (3) 2" DIAMETER HOLES EVERY 3RD TRUSS BAY WITH WITH 3.14 S.I. NET FREE VENTILATION AREA PER LINEAR FOOT. HIGH AND/OR LOW VENTS (SLOPED ROOF): LOW PROFILE O'HAGIN STANDARD LINE, CHARCOAL COLOR OR APPROVED EQUAL WITH 72 S.I. NET FREE VENTILATION AREA PER VENT. ROOF AREA #3 : REQUIRED VENTILATION 6,648 S.F. / 150 = 44.32 X 144 = 6,382 S.I. LOW = 50% X 6,382 = 3,191 S.I. HIGH = 50% X 6,382 = 3,191 S.I. PROVIDED VENTILATION LOW (EAVES) = 440 LF X 3.14 S.I. = 1,382 S.I. LOW (SLOPED) = 26 VENTS X 72 S.I. = 1,872 S.I. TOTAL LOW = 3,254 S.I. HIGH (SLOPED) = 10 VENTS X 72 S.I. = 720 S.I. HIGH (PARAPET) = 24 VENTS X 110 S.I. = 2,640 S.I. TOTAL HIGH = 3,360 S.I. ROOF AREA #2 : REQUIRED VENTILATION 151 S.F. / 150 = 1 X 144 = 145 S.I. LOW = 50% X 145 = 73 S.I. HIGH = 50% X 145 = 73 S.I. PROVIDED VENTILATION LOW (EAVES) = 33.6 LF X 3.14 S.I. = 106 S.I. HIGH (SLOPED) = 2 VENTS X 72 S.I. = 144 S.I. DOWNSPOUT - REFER TO CIVIL DWGS FOR TERMINATIONS AND/OR TIE-IN TO STORM DRAIN SYSTEM. PROVIDE SPLASH BLOCK AT TERMINATIONS TO GRADE OR LOW ROOFS. SEE ELEVATIONS FOR ADDITIONAL INFORMATION. ROOF PLAN LEGEND ATTIC VENTILATION CALCS ROOF AREA #1 : REQUIRED VENTILATION 3,054 S.F. / 150 = 20.36 X 144 = 2,932 S.I. LOW = 50% X 2,932 = 1,466 S.I. HIGH = 50% X 2,932 = 1,466 S.I. PROVIDED VENTILATION LOW (FLAT) = 3 VENTS X 520 S.I. = 1,560 S.I. HIGH (FLAT) = 3 VENTS X 520 S.I. = 1,560 S.I.
X AD-61.0X AD-61.0 1. THE SOLAR ZONE SHALL COMPLY WITH ACCESS, PATHWAY, SMOKE VENTILATION, AND SPACING REQUIREMENTS AS SPECIFIED IN TITLE 24, PART 9 OR OTHER PARTS OF TITLE 24 OR IN ANY REQUIREMENTS ADOPTED BY A LOCAL JURISDICTION. 2. NO OBSTRUCTIONS, INCLUDING BUT NOT LIMITED TO VENTS, CHIMNEYS, ARCHITECTURAL FEATURES, AND ROOF MOUNTED EQUIPMENT, SHALL BE LOCATED IN THE SOLAR ZONE. 3. SOLAR ZONE MUST BE LOCATED NO CLOSER THAN TWICE THE DISTANCE, MEASURED IN THE HORIZONTAL PLANE, OF THE HEIGHT DIFFERENCE BETWEEN THE HIGHEST POINT OF THE OBSTRUCTION AND THE HORIZONTAL PROJECTION OF THE NEAREST POINT OF THE SOLAR ZONE, MEASURED IN THE VERTICAL PLANE. 4. PROVIDE 2" CONDUIT BETWEEN SOLAR-READY ZONE AND ELECTRICAL ROOM(S). SOLAR READY CALCULATION: TOTAL ROOF AREA: XX,XXX SF REQUIRED SOLAR READY AREA (15% OF TOTAL ROOF AREA): X,XXX SF PROVIDED SOLAR READY AREA: X,XXX SF X AD-61.0X AD-61.0 ALL VENTILATION CALCULATIONS ARE BASED ON:X AD-61.0 X AD-61.0 X AD-61.0
123456
7 BUILDING A ROOF LEVEL PLAN SCALE: 3/32"=1'-0"
1 City Council 23 – 10512/6/2022 11'-2 1/2" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT LEASING T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 123.21' FF 134.42' FF 144.50' FF HDR HDR HDR HDR 9'-1" 7TH FL SUBFLOOR T.O.PL HDR
9'-0" 8'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1" HDR HDR ROOF SHT'G FITNESS UNIT 3.4A LOBBY UNIT 2.1D-R UNIT 2.1A 12'-1" UNIT 4.1A-R UNIT 4.1F UNIT 0.1A UNIT 2.1E-R UNIT 2.1B UNIT 4.1B-R STAIR A3 UNIT 2.4A UNIT 2.4A UNIT 4.1G UNIT 4.1H UNIT 4.1H UNIT 0.1B UNIT 0.1B UNIT 0.1B UNIT 2.1F-R UNIT 2.1E-R UNIT 2.1F-R UNIT 2.1C UNIT 2.1B UNIT 2.1C UNIT 4.1C-R UNIT 4.1B-R UNIT 2.4B UNIT 4.1C-R STAIR A3 UNIT 2.4A UNIT 2.4B UNIT 4.1H UNIT 4.1H UNIT 0.1B UNIT 0.1B T
S
R
Q
P
N
M
L H.8
9'-1 39/256" 9'-1" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB ON GRADE T.O.PL 3RD FL SUBFLOOR 4TH FL SUBFLOOR 5TH FL SUBFLOOR ROOF SHT'G. T.O.PL T.O.PL 2ND FL SUBFLOOR 124.70' FF HDR HDR HDR HDR HDR T.O.PL T.O.PL 8'-0 39/256" 8'-1" 8'-1" 8'-1" 8'-1"
GA2-43 UNIT 4.1A UNIT 4.1B UNIT 4.1C UNIT 4.1B UNIT 4.1C UNIT 0.3A UNIT 0.3B UNIT 0.3B UNIT 0.3B UNIT 0.3C STAIR A2 10 9 8.8
8 7
6 5 4.3
3 9'-1 39/256" 9'-1" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB ON GRADE T.O.PL 3RD FL SUBFLOOR 4TH FL SUBFLOOR 5TH FL SUBFLOOR ROOF SHT'G. T.O.PL T.O.PL 2ND FL SUBFLOOR 124.70' FF HDR HDR HDR HDR HDR T.O.PL T.O.PL 8'-0 39/256" 8'-1" 8'-1" 8'-1" 8'-1" 128.58' 140.46' 150.54' 160.63' 2 TYP.
2 TYP.
4 1
3 3.1 3.3 3.2 TYP.
3 TYP. 3.1 3.2 TYP. 3.1 3.3 TYP. 3.1 BUILDING A NORTH & EAST EXTERIOR ELEVATIONSA2-20 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed.
Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL NORTH EXTERIOR ELEVATION SCALE: 3/32"=1'-0" 1 EAST EXTERIOR ELEVATION SCALE: 3/32"=1'-0"2 ELEVATION NOTES BUILDING KEY PLAN ELEVATION LEGEND/KEYNOTES EXTERIOR CEMENT PLASTER CONTROL JOINT. IN AREAS NOT ELEVATED, INSTALL TO SEGREGATE AREAS NOT EXCEEDING MORE THAN 144 SQ. FT. ON WALLS & NOT MORE THAN 100 SQ. FT. ON HORIZONTAL APPLICATIONS. DISTANCE BETWEEN JOINTS SHALL NOT EXCEED 18 FEET IN EITHER DIRECTION OR A LENGTH-TO-WIDTH RATIO OF 2.5 TO 1. HORIZONTAL JOINTS SHALL WRAP OUTSIDE CORNERS AND RETURN TO THE NEAREST INSIDE CORNER. FLOOR CONTROL / DRAINAGE JOINT IN EXTERIOR CEMENT PLASTER EXTERIOR CEMENT PLASTER: WITH 16/20 FINISH, PAINT WINDOW/DOOR TRIM: EPS 3 1/2 WIDE X 1 1/2" THICK, SMOOTH FINISH, TYP, U.N.O. EXHAUST TERMINATION - SEE MECH. PROVIDE MINIMUM DISTANCE OF 3' BETWEEN EXHAUST VENTS AND ANY OPENINGS INTO THE BUILDING RETAIL STOREFRONT SMOOTH FIBER CEMENT SIDING: METAL GUARDRAIL CONDUCTOR HEAD & OVERFLOW, COLOR TO MATCH ADJACENT SURFACE 1. ALL VERTICAL DIMENSIONS SHOWN ARE FROM THE TOP OF CONCRETE SLAB (WHERE OCCURS) OR TOP OF FLOOR SHT'G, U.N.O. VERIFY SLAB ELEVATION WITH CIVIL. 2. EXTEND AND RETURN FINISH MATERIALS AND COLORS TO INSIDE CORNERS, U.N.O. 3. U.N.O., PAINT EXPOSED METAL FLASHING & TRIM TO MATCH COLOR OF ADJACENT SURFACE. ALLOW FOR COLOR CHANGES ACROSS VARYING MATERIALS AND COLORS. 4. PROVIDE FLEXIBLE SEALED FLASHING AT ALL ITEMS PENETRATING EXTERIOR WALL CONSTRUCTION PER MANUFACTER'S RECOMMENDATIONS. 5. PROVIDE EXTERIOR WALL OPENING FLASHING PER 6. EXTEND SUBSTRATE SHEATHING TO NEAREST INSIDE OR OUTSIDE CORNER TO OBTAIN A FLUSH SUBSTRATE SURFACE. 7. DETERMINE GAUGE OF EXTERIOR METAL FRAMING BASED ON DEPTH, SPACING AND WIND LOADS INDICATED IN DRAWINGS. REFER TO STRUCTURAL DRAWINGS FOR WIND LOADS. 8. PROVIDE BLOCKING AND/OR APPROPRIATE BACKING FOR ALL RECESSED AND SURFACE-MOUNTED ITEMS. VERIFY LOCATIONS PRIOR TO CLOSURE OF FRAMING. 9. SIGNAGE: PROVIDE BLOCKING AND BACKING FOR SIGN MOUNTING. PROVIDE LOCKABLE ACCESS TO POWER AND SERVICE CONNECTIONS. VERIFY SIGN LOCATIONS PRIOR TO CLOSURE OF FRAMING. 10. ALIGN FINISH HEAD HEIGHT OF WINDOW AND PATIO DOOR TYPICAL AT ALL UNITS, U.N.O. GENERAL CONTRACTOR TO COORDINATE THIS REQUIREMENT WITH FRAMING SUB CONTRACTOR. 11. PROVIDE 5/8" TYPE X GYP. SHEATHING WHERE FIREWALL TERMINATES AT EXTERIOR WALL. 12. REFER TO COLOR BLOCKING AND/OR PAINTER'S EXHIBITS FOR FINAL COLOR AND FINISH SELECTIONS. 13. FOR PREFINISHED ITEMS, SUBMIT MANUFACTURER'S COLOR PALETTE TO ARCHITECT FOR REVIEW. ALL COLOR AND FINISH SELECTIONS, INCLUDING PREMIUM SELECTIONS, SHALL BE AVAILABLE FOR THE BID PRICE. 14. MOUNT ALL WALL LIGHT FIXTURES AT 6'- 8" MIN TO BOTTOM OF FIXTURE, U.N.O. 15. EXTERIOR FINISHES: SIZING, GAUGE, ATTACHMENTS, WRB, ASSOCIATED COMPONENTS AND GENERAL INSTALLATION SHALL BE CONSISTENT WITH MANUFACTURER'S RECOMMENDATIONS. 4" DIAMETER ALUMINUM DOWNSPOUT, COLOR TO MATCH ADJACENT SURFACE, U.N.O. EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 2 1/2" WIDE x 1 1/2" DEEP EXPOSED CMU: W/ 2" THICK MATCHING CAP AT TOP OF WALL GROUT: CONCAVE PROFILE EXPOSED CONCRETE EXTERIOR CEMENT PLASTER: O/ WRB WITH SMOOTH HARD TROWELED FINISH & PAINT - AD-51.0- AD-51.0 ADHERED MASONRY VENEER:
3 AD-26 24 AD-51.0 GLASS GUARDRAIL METAL CANOPY EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 6" WIDE x 1 1/2" DEEP 11 AD-51.0 11 AD-51.0 22 AD-61.0 - AD-XX- AD-51.0
3 AD-51.1 22 AD-51.0 OR 2.1
2133.14 14 AD-61.05 SIGNAGE6 ART MURAL 7 TRELLIS8 FLAT CONCRETE ROOF TILE N
B
A 4TH STREET MORTIMER STREET 5TH STREET
FRENCH STREET
MINTER STREET GFRC WAINSCOT:
9 ADDRESS SIGN - SEE OCFA NOTES FOR MORE INFORMATION 3.2 EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 4" WIDE x 1 1/2" DEEP 3.3 EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 10" WIDE x 3" DEEP 3.4 EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 12" WIDE x 1 1/2" DEEP 1 2
City Council 23 – 10612/6/2022 1ST FL T.O. SLAB AT RESTAURANT T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 122.66' FF 134.42' FF 144.50' FF HDR HDR HDR HDR 7TH FL SUBFLOOR T.O.PL HDR HDR HDR ROOF SHT'G 11'-2 1/2" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT LEASING T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 123.21' FF 134.42' FF 144.50' FF HDR HDR HDR HDR 9'-1" 7TH FL SUBFLOOR T.O.PL HDR
9'-0" 8'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1" HDR HDR ROOF SHT'G 123.80' AVERAGE GRADE PLANE AVERAGE HEIGHT OF ROOF 71'-7 1/2" RESTAURANT LEASING / AMENITY FTINESS UNIT 2.6A-R UNIT 2.2C-R UNIT 2.2E UNIT 2.4B UNIT 2.6A-R UNIT 2.2B-R POOL DECK UNIT 2.2D UNIT 2.4A UNIT 2.6A-R UNIT 2.2B-R RETAIL UNIT 2.2D UNIT 2.4A UNIT 2.2D UNIT 2.2E UNIT 2.4A ROOF DECK UNIT 2.2F-R UNIT 2.4B UNIT 2.6A-R UNIT 2.2B-R 2 5 5.2 6.2 7.2 8.2 8.5 9.7 11 12 13
DA2-41 E A2-42 123.80' AVERAGE GRADE PLANE AVERAGE HEIGHT OF ROOF 71'-7 1/2" HDR HDR HDR HDR HDR HDR HDR 1ST FL T.O. SLAB AT RESTAURANT T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 122.66' FF 134.42' FF 144.50' FF 7TH FL SUBFLOOR T.O.PL ROOF SHT'G UNIT 0.1D UNIT 4.1K UNIT 2.6A-R UNIT 0.1D UNIT 0.1D UNIT 0.1C ENTRY UNIT 4.1K UNIT 4.1J UNIT 3.2B UNIT 3.2A UNIT 2.6A-R UNIT 2.6A-R RESTARAUNT STAIR A4 A
B C.2
D
G G.7
K
L
M
N
P
Q
R
S
T 128.58' 140.46' 150.54' 160.63'
CA2-41 A A2-40 B A2-40
F A2-42
6 1 TYP. TYP. 4 2.1 TYP. 1 TYP. 4 TYP. 9 2 TYP. 4 TYP. 1 TYP. 5 2 TYP. TYP. 4 1 TYP.TYP. 3.1 3.2 TYP.
3 3.3 TYP. 3.2 3.1 TYP. 3.1 BUILDING A SOUTH & WEST EXTERIOR ELEVATIONS SOUTH EXTERIOR ELEVATION SCALE: 3/32"=1'-0" 1 A2-21 WEST EXTERIOR ELEVATION SCALE: 3/32"=1'-0"2 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL ELEVATION NOTES BUILDING KEY PLAN ELEVATION LEGEND/KEYNOTES EXTERIOR CEMENT PLASTER CONTROL JOINT. IN AREAS NOT ELEVATED, INSTALL TO SEGREGATE AREAS NOT EXCEEDING MORE THAN 144 SQ. FT. ON WALLS & NOT MORE THAN 100 SQ. FT. ON HORIZONTAL APPLICATIONS. DISTANCE BETWEEN JOINTS SHALL NOT EXCEED 18 FEET IN EITHER DIRECTION OR A LENGTH-TO-WIDTH RATIO OF 2.5 TO 1. HORIZONTAL JOINTS SHALL WRAP OUTSIDE CORNERS AND RETURN TO THE NEAREST INSIDE CORNER. FLOOR CONTROL / DRAINAGE JOINT IN EXTERIOR CEMENT PLASTER EXTERIOR CEMENT PLASTER: WITH 16/20 FINISH, PAINT WINDOW/DOOR TRIM: EPS 3 1/2 WIDE X 1 1/2" THICK, SMOOTH FINISH, TYP, U.N.O. EXHAUST TERMINATION - SEE MECH. PROVIDE MINIMUM DISTANCE OF 3' BETWEEN EXHAUST VENTS AND ANY OPENINGS INTO THE BUILDING RETAIL STOREFRONT SMOOTH FIBER CEMENT SIDING: METAL GUARDRAIL CONDUCTOR HEAD & OVERFLOW, COLOR TO MATCH ADJACENT SURFACE 1. ALL VERTICAL DIMENSIONS SHOWN ARE FROM THE TOP OF CONCRETE SLAB (WHERE OCCURS) OR TOP OF FLOOR SHT'G, U.N.O. VERIFY SLAB ELEVATION WITH CIVIL. 2. EXTEND AND RETURN FINISH MATERIALS AND COLORS TO INSIDE CORNERS, U.N.O. 3. U.N.O., PAINT EXPOSED METAL FLASHING & TRIM TO MATCH COLOR OF ADJACENT SURFACE. ALLOW FOR COLOR CHANGES ACROSS VARYING MATERIALS AND COLORS. 4. PROVIDE FLEXIBLE SEALED FLASHING AT ALL ITEMS PENETRATING EXTERIOR WALL CONSTRUCTION PER MANUFACTER'S RECOMMENDATIONS. 5. PROVIDE EXTERIOR WALL OPENING FLASHING PER 6. EXTEND SUBSTRATE SHEATHING TO NEAREST INSIDE OR OUTSIDE CORNER TO OBTAIN A FLUSH SUBSTRATE SURFACE. 7. DETERMINE GAUGE OF EXTERIOR METAL FRAMING BASED ON DEPTH, SPACING AND WIND LOADS INDICATED IN DRAWINGS. REFER TO STRUCTURAL DRAWINGS FOR WIND LOADS. 8. PROVIDE BLOCKING AND/OR APPROPRIATE BACKING FOR ALL RECESSED AND SURFACE-MOUNTED ITEMS. VERIFY LOCATIONS PRIOR TO CLOSURE OF FRAMING. 9. SIGNAGE: PROVIDE BLOCKING AND BACKING FOR SIGN MOUNTING. PROVIDE LOCKABLE ACCESS TO POWER AND SERVICE CONNECTIONS. VERIFY SIGN LOCATIONS PRIOR TO CLOSURE OF FRAMING. 10. ALIGN FINISH HEAD HEIGHT OF WINDOW AND PATIO DOOR TYPICAL AT ALL UNITS, U.N.O. GENERAL CONTRACTOR TO COORDINATE THIS REQUIREMENT WITH FRAMING SUB CONTRACTOR. 11. PROVIDE 5/8" TYPE X GYP. SHEATHING WHERE FIREWALL TERMINATES AT EXTERIOR WALL. 12. REFER TO COLOR BLOCKING AND/OR PAINTER'S EXHIBITS FOR FINAL COLOR AND FINISH SELECTIONS. 13. FOR PREFINISHED ITEMS, SUBMIT MANUFACTURER'S COLOR PALETTE TO ARCHITECT FOR REVIEW. ALL COLOR AND FINISH SELECTIONS, INCLUDING PREMIUM SELECTIONS, SHALL BE AVAILABLE FOR THE BID PRICE. 14. MOUNT ALL WALL LIGHT FIXTURES AT 6'- 8" MIN TO BOTTOM OF FIXTURE, U.N.O. 15. EXTERIOR FINISHES: SIZING, GAUGE, ATTACHMENTS, WRB, ASSOCIATED COMPONENTS AND GENERAL INSTALLATION SHALL BE CONSISTENT WITH MANUFACTURER'S RECOMMENDATIONS. 4" DIAMETER ALUMINUM DOWNSPOUT, COLOR TO MATCH ADJACENT SURFACE, U.N.O. EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 2 1/2" WIDE x 1 1/2" DEEP EXPOSED CMU: W/ 2" THICK MATCHING CAP AT TOP OF WALL GROUT: CONCAVE PROFILE EXPOSED CONCRETE EXTERIOR CEMENT PLASTER: O/ WRB WITH SMOOTH HARD TROWELED FINISH & PAINT - AD-51.0- AD-51.0 ADHERED MASONRY VENEER:
3 AD-26 24 AD-51.0 GLASS GUARDRAIL METAL CANOPY EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 6" WIDE x 1 1/2" DEEP 11 AD-51.0 11 AD-51.0 22 AD-61.0 - AD-XX- AD-51.0
3 AD-51.1 22 AD-51.0 OR 2.12
133.14 14 AD-61.05 SIGNAGE6 ART MURAL 7 TRELLIS8 FLAT CONCRETE ROOF TILE N
B
A 4TH STREET MORTIMER STREET 5TH STREET
FRENCH STREET
MINTER STREET GFRC WAINSCOT:
9 ADDRESS SIGN - SEE OCFA NOTES FOR MORE INFORMATION 3.2 EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 4" WIDE x 1 1/2" DEEP 3.3 EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 10" WIDE x 3" DEEP 3.4 EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 12" WIDE x 1 1/2" DEEP 1 2
City Council 23 – 10712/6/2022 UNIT 2.1G-R UNIT 1.1B-R CLUBHOUSE UNIT 2.1H-R UNIT 2.1H-R RESTROOMS CORRIDOR UNIT 1.2B-R UNIT 1.2B-R UNIT 1.2B-R UNIT 1.2B-R UNIT 1.2B-R UNIT 1.1B-R UNIT 1.1B-R UNIT 1.1B-R UNIT 1.2B UNIT 1.2B UNIT 1.2B UNIT 1.2B UNIT 1.2B UNIT 1.1C UNIT 1.1E UNIT 1.1E 8'-11 1/2" 9'-1" 9'-1" 9'-1" T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 144.50' FF HDR HDR HDR HDR 9'-1" 7TH FL SUBFLOOR T.O.PL HDR
8'-0" 8'-1" 8'-1" 8'-1" 8'-1" ROOF SHT'G STAIR A4 UNIT 2.5A UNIT 2.5B UNIT 2.5B UNIT 2.5B UNIT 2.5B UNIT 1.2A UNIT 1.2B UNIT 1.2B UNIT 1.2B UNIT 1.2B 11'-5" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT RETAIL T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 123.00' FF 134.42' FF 144.50 FF HDR HDR HDR HDR9'-1" 7TH FL SUBFLOOR T.O.PL HDR 9'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1" 8'-1" HDR HDR ROOF SHT'G. UNIT 2.2E UNIT 2.2D UNIT 2.2E UNIT 2.2D UNIT 2.2D UNIT 1.1E-R UNIT 1.1E-R UNIT 1.1D-R UNIT 1.1D-R UNIT 1.1A-R UNIT 1.2B UNIT 1.2B UNIT 1.2B UNIT 1.2B UNIT 1.2A 11'-5" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT RETAIL T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 123.00' FF 134.42' FF 144.50' FF HDR HDR HDR HDR9'-1" 7TH FL SUBFLOOR T.O.PL HDR 9'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1" 8'-1" HDR HDR ROOF SHT'G 2 TYP.
2 TYP.
4 TYP. 1 TYP.
2 TYP. 3.1 3.1 3.1 3.1 TYP. 3.1 3.2 TYP. 3.3 3.4 TYP. 3.1 3.2 TYP. 3 TYP. 3.1 3.2 TYP. COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A COURTYARD ELEVATIONSA2-22 BUILDING # SOUTH COURTYARD EXTERIOR ELEVATION SCALE: 1/8"=1'-0" 1 WEST COURTYARD EXTERIOR ELEVATION SCALE: 1/8"=1'-0"2 ELEVATION NOTES BUILDING KEY PLAN ELEVATION LEGEND/KEYNOTES EXTERIOR CEMENT PLASTER CONTROL JOINT. IN AREAS NOT ELEVATED, INSTALL TO SEGREGATE AREAS NOT EXCEEDING MORE THAN 144 SQ. FT. ON WALLS & NOT MORE THAN 100 SQ. FT. ON HORIZONTAL APPLICATIONS. DISTANCE BETWEEN JOINTS SHALL NOT EXCEED 18 FEET IN EITHER DIRECTION OR A LENGTH-TO-WIDTH RATIO OF 2.5 TO 1. HORIZONTAL JOINTS SHALL WRAP OUTSIDE CORNERS AND RETURN TO THE NEAREST INSIDE CORNER. FLOOR CONTROL / DRAINAGE JOINT IN EXTERIOR CEMENT PLASTER EXTERIOR CEMENT PLASTER: WITH 16/20 FINISH, PAINT WINDOW/DOOR TRIM: EPS 3 1/2 WIDE X 1 1/2" THICK, SMOOTH FINISH, TYP, U.N.O. EXHAUST TERMINATION - SEE MECH. PROVIDE MINIMUM DISTANCE OF 3' BETWEEN EXHAUST VENTS AND ANY OPENINGS INTO THE BUILDING RETAIL STOREFRONT SMOOTH FIBER CEMENT SIDING: METAL GUARDRAIL CONDUCTOR HEAD & OVERFLOW, COLOR TO MATCH ADJACENT SURFACE 1. ALL VERTICAL DIMENSIONS SHOWN ARE FROM THE TOP OF CONCRETE SLAB (WHERE OCCURS) OR TOP OF FLOOR SHT'G, U.N.O. VERIFY SLAB ELEVATION WITH CIVIL. 2. EXTEND AND RETURN FINISH MATERIALS AND COLORS TO INSIDE CORNERS, U.N.O. 3. U.N.O., PAINT EXPOSED METAL FLASHING & TRIM TO MATCH COLOR OF ADJACENT SURFACE. ALLOW FOR COLOR CHANGES ACROSS VARYING MATERIALS AND COLORS. 4. PROVIDE FLEXIBLE SEALED FLASHING AT ALL ITEMS PENETRATING EXTERIOR WALL CONSTRUCTION PER MANUFACTER'S RECOMMENDATIONS. 5. PROVIDE EXTERIOR WALL OPENING FLASHING PER 6. EXTEND SUBSTRATE SHEATHING TO NEAREST INSIDE OR OUTSIDE CORNER TO OBTAIN A FLUSH SUBSTRATE SURFACE. 7. DETERMINE GAUGE OF EXTERIOR METAL FRAMING BASED ON DEPTH, SPACING AND WIND LOADS INDICATED IN DRAWINGS. REFER TO STRUCTURAL DRAWINGS FOR WIND LOADS. 8. PROVIDE BLOCKING AND/OR APPROPRIATE BACKING FOR ALL RECESSED AND SURFACE-MOUNTED ITEMS. VERIFY LOCATIONS PRIOR TO CLOSURE OF FRAMING. 9. SIGNAGE: PROVIDE BLOCKING AND BACKING FOR SIGN MOUNTING. PROVIDE LOCKABLE ACCESS TO POWER AND SERVICE CONNECTIONS. VERIFY SIGN LOCATIONS PRIOR TO CLOSURE OF FRAMING. 10. ALIGN FINISH HEAD HEIGHT OF WINDOW AND PATIO DOOR TYPICAL AT ALL UNITS, U.N.O. GENERAL CONTRACTOR TO COORDINATE THIS REQUIREMENT WITH FRAMING SUB CONTRACTOR. 11. PROVIDE 5/8" TYPE X GYP. SHEATHING WHERE FIREWALL TERMINATES AT EXTERIOR WALL. 12. REFER TO COLOR BLOCKING AND/OR PAINTER'S EXHIBITS FOR FINAL COLOR AND FINISH SELECTIONS. 13. FOR PREFINISHED ITEMS, SUBMIT MANUFACTURER'S COLOR PALETTE TO ARCHITECT FOR REVIEW. ALL COLOR AND FINISH SELECTIONS, INCLUDING PREMIUM SELECTIONS, SHALL BE AVAILABLE FOR THE BID PRICE. 14. MOUNT ALL WALL LIGHT FIXTURES AT 6'- 8" MIN TO BOTTOM OF FIXTURE, U.N.O. 15. EXTERIOR FINISHES: SIZING, GAUGE, ATTACHMENTS, WRB, ASSOCIATED COMPONENTS AND GENERAL INSTALLATION SHALL BE CONSISTENT WITH MANUFACTURER'S RECOMMENDATIONS. 4" DIAMETER ALUMINUM DOWNSPOUT, COLOR TO MATCH ADJACENT SURFACE, U.N.O. EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 2 1/2" WIDE x 1 1/2" DEEP EXPOSED CMU: W/ 2" THICK MATCHING CAP AT TOP OF WALL GROUT: CONCAVE PROFILE EXPOSED CONCRETE EXTERIOR CEMENT PLASTER: O/ WRB WITH SMOOTH HARD TROWELED FINISH & PAINT - AD-51.0- AD-51.0 ADHERED MASONRY VENEER:
3 AD-26 24 AD-51.0 GLASS GUARDRAIL METAL CANOPY EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 6" WIDE x 1 1/2" DEEP 11 AD-51.0 11 AD-51.0 22 AD-61.0 - AD-XX- AD-51.0
3 AD-51.1 22 AD-51.0 OR 2.1
2133.14 14 AD-61.05 SIGNAGE6 ART MURAL 7 TRELLIS8 FLAT CONCRETE ROOF TILE N
B
A 4TH STREET MORTIMER STREET 5TH STREET
FRENCH STREET
MINTER STREET GFRC WAINSCOT:
9 ADDRESS SIGN - SEE OCFA NOTES FOR MORE INFORMATION 3.2 EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 4" WIDE x 1 1/2" DEEP 3.3 EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 10" WIDE x 3" DEEP 3.4 EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 12" WIDE x 1 1/2" DEEP EAST COURTYARD EXTERIOR ELEVATION SCALE: 1/8"=1'-0" 3 1
3 2
City Council 23 – 10812/6/2022
PARKING GARAGE CORR UNIT UNIT CORR CORR CORR CORR CLUBHOUSE RETAIL POOL SPA 11'-5 3/64" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT RETAIL T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 123.00' FF 134.42' FF 144.50' FF HDR HDR HDR HDR 9'-1" 7TH FL SUBFLOOR T.O.PL HDR HDR
8'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1" UNIT
T
S
R
Q P.6 P.5 P.4
P N.4 N.1
N M.3
M L.6
L
K J.5
H G.9 G.7
G
F
E
D C.2
C
B
A UNIT UNIT UNIT DECK DECK DECK DECK DECK UNIT
PROPERTY LINE
11'-9 1/8" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT RESTAURANT T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 122.66' FF 134.42' FF 144.50' FF HDR HDR HDR HDR 9'-1" 7TH FL SUBFLOOR T.O.PL HDR HDR HDR
9'-0" 8'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1" UNIT UNIT UNIT UNIT DECK DECK DECK DECK UNIT DECK UNIT UNIT CORR CORR CORR CORR CORR CORR CORR UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT CORR CORR CORR CORR CORR CORR CORR UNIT UNIT UNIT 1 2 2.1 4.4 4.8 5.2 5.5 6.2 7.2 8.2 8.5 8.7 9.6 9.7 10.110.210.3 11 11.2 11.511.7 12 13 2 AD-33
4 AD-33 TYP. 1 HOUR CORRIDOR FLR / CLG ASSEMBLY 20 AD-22.1 TYP. 1 HOUR ROOF / CLG ASSEMBLY 9 AD-21 TYP. 3 HOUR HORIZ. ASSEMBLY - CONCRETE STRUCTURAL SLAB 17 AD-21 TYP. 1 HOUR HORIZ. ASSEMBLY - CONCRETE STRUCTURAL SLAB 13 AD-21 TYP. 1 HOUR UNIT / UNIT FLR / CLG ASSEMBLY 1 AD-21 TYP. 1 HOUR UNIT / CORRIDOR ASSEMBLY 20 AD-22.1 TYP. 1 HOUR CORRIDOR FLR / CLG ASSEMBLY 20 AD-22.1 TYP. 1 HOUR ROOF / CLG ASSEMBLY 9 AD-21 TYP. 3 HOUR HORIZ. ASSEMBLY - CONCRETE STRUCTURAL SLAB 17 AD-21 TYP. 1 HOUR HORIZ. ASSEMBLY - CONCRETE STRUCTURAL SLAB 13 AD-21 TYP. 1 HOUR UNIT / UNIT FLR / CLG ASSEMBLY 1 AD-21TYP. 1 HOUR UNIT / CORRIDOR ASSEMBLY 20 AD-22.1 TYP. "DRYCRETE" CONCRETE MAT SLAB TYP. "DRYCRETE" CONCRETE MAT SLAB BUILDING A SECTIONS A2-30 OVERALL BUILDING SECTION B SCALE: 3/32"=1'-0" 2 OVERALL BUILDING SECTION A SCALE: 3/32"=1'-0"1 COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 10912/6/2022
PROPERTY LINE
11'-9 1/8" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT RESTAURANT T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 122.66' FF 134.42' FF 144.50' FF HDR HDR HDR HDR 9'-1" 7TH FL SUBFLOOR T.O.PL HDR HDR HDR
9'-0" 8'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1" RESTAURANT RETAIL UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT UNIT COURTYARD 1 2 2.1 4.4 4.8 5.2 5.5 TYP. 1 HOUR ROOF / CLG ASSEMBLY 9 AD-21 TYP. 3 HOUR HORIZ. ASSEMBLY - CONCRETE STRUCTURAL SLAB 17 AD-21 TYP. 1 HOUR UNIT / UNIT FLR / CLG ASSEMBLY 1 AD-21 TYP. "DRYCRETE" CONCRETE MAT SLAB BUILDING A SECTIONS OVERALL BUILDING SECTION C SCALE: 3/32"=1'-0" 1 A2-31 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL
City Council 23 – 11012/6/2022 11'-9 1/8" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT RESTAURANT T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 122.66' FF 134.42' FF 144.50' FF HDR HDR HDR HDR 9'-1" 7TH FL SUBFLOOR T.O.PL HDR HDR HDR
9'-0" 8'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1"
A A2-40 UNIT UNIT UNIT UNIT DECK DECK DECK DECK UNIT DECK UNIT UNIT
PROPERTY LINE
9 AD-21
1 AD-21
4 AD-21 17 AD-21 13 AD-21 1-HR ROOF/CEILING1-HR FLOOR/CEILING 3-HR FLOOR/CEILING 2-HR FLOOR/CEILING NON-RATED DECK/CEILING TYP. 2 11'-9 1/8" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT RESTAURANT T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 122.66' FF 134.42' FF 144.50' FF HDR HDR HDR HDR9'-1" 7TH FL SUBFLOOR T.O.PL HDR HDR HDR 9'-0" 8'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1"
B A2-40 UNIT UNIT UNIT UNIT UNIT UNIT ROOF DECK
PROPERTY LINE
9 AD-211 AD-21 17 AD-21 13 AD-21 1-HR ROOF/CEILING 1-HR FLOOR/CEILING 3-HR FLOOR/CEILING 2-HR FLOOR/CEILING COPYRIGHT C It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A WALL SECTIONS A2-40 WALL SECTION 'B' SCALE: 1/4"=1'-0" B WALL SECTION 'A' SCALE: 1/4"=1'-0"
A WALL SECTION NOTES 1. STRUCTURAL MEMBERS SHOWN IN ARCHITECTURAL SECTIONS ARE DIAGRAMMATIC IN NATURE AND SHOULD NOT BE RELIED UPON AS AN ACTUAL REPRESENTATION OF STRUCTURAL MEMBERS. REFER TO STRUCTURAL DRAWINGS FOR SIZES AND SPECIFIC CONFIGURATION OF STRUCTURAL MEMBERS. 2. FOR FIRE RATINGS OF WALLS SEE SHEETS A0-11 THRU A0-25. 3. FOR ASSEMBLIES, FIRE RATINGS, LISTINGS AND RELATED CONSTRUCTION DETAILS SEE 4. COLUMNS & PRIMARY STRUCTURAL FRAME MEMBERS SHALL BE PROVIDED WITH INDIVIDUAL ENCASEMENT FIRE PROTECTION AS REQUIRED BY CBC SECTIONS 704. - AD-28
- AD-28 TO TYPICAL INSULATION VALUES ROOF / CEILING INSULATION LOCATION R-30 VALUE METAL STUD EXTERIOR WALL R-?? - AD-28 INFORMATION ABOVE IS BASED ON ENERGY CALCULATIONS PROVIDED BY VCA GREEN, DATED 07/01/2021. GC TO VERIFY THE INFORMATION ABOVE IS CONSISTENT WITH THE MOST CURRENT ENERGY CALCULATIONS. WOOD STUD EXTERIOR WALL R-21 FIRE STOPPING LEGEND UL SERIES LISTING --
- - -- - -
- - -- -- - PENETRATION DESCRIPTION ROUND BLANK OPENING RECTANGULAR BLANK OPNG BLANK OPNG WALL CHASE SINGLE PIPE PENETRATION MULTIPLE PIPE PEN SINGLE PIPE WALL CHASE DRAIN PER IN FLR BATH TUB PER IN FLR TOILET PEN IN FLOOR ROUND DUCT PENETRATION RECTANGULAR DUCT PEN CONC FLOORS CONC & MASONRY WALLS WOOD FRAME WALLS WOOD FRAME FLOORS C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-1000 C-AJ-1000 W-L-0000 W-L-0000 W-L-1000 W-L-1000 C-AJ-7000 C-AJ-7000 C-AJ-7000 C-AJ-7000 F-A-2000 F-A-1000 F-B-1000 W-L-7000 W-L-7000 F-C-0000 F-C-1000 F-C-8000 F-C-1000 F-C-2000 F-C-2000 F-C-7000 F-C-7000 2-HR FIRE BARRIER FRAMED ASSEMBLIES 3-HR HORIZONTAL SEPARATION SECTION LEGEND CONCRETE CMU ELEVATION KEYNOTES RETAIL STOREFRONT METAL GUARDRAIL EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 2 1/2" WIDE x 1 1/2" DEEP GLASS GUARDRAIL METAL CANOPY EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 6" WIDE x 1 1/2" DEEP 2.12 133.145 SIGNAGE6 ART MURAL 7 TRELLIS8 FLAT CONCRETE ROOF TILE9 ADDRESS SIGN - SEE OCFA NOTES FOR MORE INFORMATION ELEVATION NOTES 1. ALL VERTICAL DIMENSIONS SHOWN ARE FROM THE TOP OF CONCRETE SLAB (WHERE OCCURS) OR TOP OF FLOOR SHT'G, U.N.O. VERIFY SLAB ELEVATION WITH CIVIL. 2. EXTEND AND RETURN FINISH MATERIALS AND COLORS TO INSIDE CORNERS, U.N.O. 3. U.N.O., PAINT EXPOSED METAL FLASHING & TRIM TO MATCH COLOR OF ADJACENT SURFACE. ALLOW FOR COLOR CHANGES ACROSS VARYING MATERIALS AND COLORS. 4. PROVIDE FLEXIBLE SEALED FLASHING AT ALL ITEMS PENETRATING EXTERIOR WALL CONSTRUCTION PER MANUFACTER'S RECOMMENDATIONS. 5. PROVIDE EXTERIOR WALL OPENING FLASHING PER 6. EXTEND SUBSTRATE SHEATHING TO NEAREST INSIDE OR OUTSIDE CORNER TO OBTAIN A FLUSH SUBSTRATE SURFACE. 7. DETERMINE GAUGE OF EXTERIOR METAL FRAMING BASED ON DEPTH, SPACING AND WIND LOADS INDICATED IN DRAWINGS. REFER TO STRUCTURAL DRAWINGS FOR WIND LOADS. 8. PROVIDE BLOCKING AND/OR APPROPRIATE BACKING FOR ALL RECESSED AND SURFACE-MOUNTED ITEMS. VERIFY LOCATIONS PRIOR TO CLOSURE OF FRAMING. 9. SIGNAGE: PROVIDE BLOCKING AND BACKING FOR SIGN MOUNTING. PROVIDE LOCKABLE ACCESS TO POWER AND SERVICE CONNECTIONS. VERIFY SIGN LOCATIONS PRIOR TO CLOSURE OF FRAMING. 10. ALIGN FINISH HEAD HEIGHT OF WINDOW AND PATIO DOOR TYPICAL AT ALL UNITS, U.N.O. GENERAL CONTRACTOR TO COORDINATE THIS REQUIREMENT WITH FRAMING SUB CONTRACTOR. 11. PROVIDE 5/8" TYPE X GYP. SHEATHING WHERE FIREWALL TERMINATES AT EXTERIOR WALL. 12. REFER TO COLOR BLOCKING AND/OR PAINTER'S EXHIBITS FOR FINAL COLOR AND FINISH SELECTIONS. 13. FOR PREFINISHED ITEMS, SUBMIT MANUFACTURER'S COLOR PALETTE TO ARCHITECT FOR REVIEW. ALL COLOR AND FINISH SELECTIONS, INCLUDING PREMIUM SELECTIONS, SHALL BE AVAILABLE FOR THE BID PRICE. 14. MOUNT ALL WALL LIGHT FIXTURES AT 6'- 8" MIN TO BOTTOM OF FIXTURE, U.N.O. 15. EXTERIOR FINISHES: SIZING, GAUGE, ATTACHMENTS, WRB, ASSOCIATED COMPONENTS AND GENERAL INSTALLATION SHALL BE CONSISTENT WITH MANUFACTURER'S RECOMMENDATIONS. 3 AD-26 24 AD-51.03 AD-51.1 22 AD-51.0 OR ELEVATION LEGEND EXTERIOR CEMENT PLASTER CONTROL JOINT. IN AREAS NOT ELEVATED, INSTALL TO SEGREGATE AREAS NOT EXCEEDING MORE THAN 144 SQ. FT. ON WALLS & NOT MORE THAN 100 SQ. FT. ON HORIZONTAL APPLICATIONS. DISTANCE BETWEEN JOINTS SHALL NOT EXCEED 18 FEET IN EITHER DIRECTION OR A LENGTH-TO-WIDTH RATIO OF 2.5 TO 1. HORIZONTAL JOINTS SHALL WRAP OUTSIDE CORNERS AND RETURN TO THE NEAREST INSIDE CORNER. FLOOR CONTROL / DRAINAGE JOINT IN EXTERIOR CEMENT PLASTER EXTERIOR CEMENT PLASTER: WITH 16/20 FINISH, PAINT WINDOW/DOOR TRIM: EPS 3 1/2 WIDE X 1 1/2" THICK, SMOOTH FINISH, TYP, U.N.O. EXHAUST TERMINATION - SEE MECH. PROVIDE MINIMUM DISTANCE OF 3' BETWEEN EXHAUST VENTS AND ANY OPENINGS INTO THE BUILDING SMOOTH FIBER CEMENT SIDING: CONDUCTOR HEAD & OVERFLOW, COLOR TO MATCH ADJACENT SURFACE 4" DIAMETER ALUMINUM DOWNSPOUT, COLOR TO MATCH ADJACENT SURFACE, U.N.O. EXPOSED CMU: W/ 2" THICK MATCHING CAP AT TOP OF WALL GROUT: CONCAVE PROFILE EXPOSED CONCRETE EXTERIOR CEMENT PLASTER: O/ WRB WITH SMOOTH HARD TROWELED FINISH & PAINT - AD-51.0- AD-51.0 ADHERED MASONRY VENEER: 11 AD-51.0 11 AD-51.0 22 AD-61.0- AD-XX- AD-51.0 14 AD-61.0 GFRC WAINSCOT:
- AD-20 PENETRATIONS OF FIRE-RESISTIVE WALLS, FLOOR/CEILINGS AND ROOF/CEILINGS SHALL BE PROTECTED AS REQUIRED IN CBC SEC. 714. FOR ADDITIONAL INFORMATION, SEE A A
B A
City Council 23 – 11112/6/2022 DA2-41 UNIT UNIT UNIT UNIT RESTAURANT ROOF DECK
PROPERTY LINE AVERAGE ROOF SURFACE
73'-6 1/2"
BUILDING HEIGHT
1 AD-21 17 AD-21 1-HR FLOOR/CEILING 3-HR FLOOR/CEILING
9 AD-21 1-HR ROOF/CEILING
11'-9 1/8" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT RESTAURANT T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 122.66' FF 134.42' FF 144.50' FF HDR HDR HDR HDR9'-1" 7TH FL SUBFLOOR T.O.PL HDR HDR HDR 9'-0" 8'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1"
CA2-41 UNIT UNIT UNIT UNIT RESTAURANT DECK DECK DECK DECK ROOF DECK 73'-6 1/2"
BUILDING HEIGHT AVERAGE ROOF SURFACE
9 AD-21
1 AD-21
4 AD-21 17 AD-21 1-HR ROOF/CEILING 1-HR FLOOR/CEILING 3-HR FLOOR/CEILING NON-RATED DECK/CEILING TYP. 21 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A WALL SECTIONS A2-41 WALL SECTION 'D' SCALE: 1/4"=1'-0" D WALL SECTION NOTES 1. STRUCTURAL MEMBERS SHOWN IN ARCHITECTURAL SECTIONS ARE DIAGRAMMATIC IN NATURE AND SHOULD NOT BE RELIED UPON AS AN ACTUAL REPRESENTATION OF STRUCTURAL MEMBERS. REFER TO STRUCTURAL DRAWINGS FOR SIZES AND SPECIFIC CONFIGURATION OF STRUCTURAL MEMBERS. 2. FOR FIRE RATINGS OF WALLS SEE SHEETS A0-11 THRU A0-25. 3. FOR ASSEMBLIES, FIRE RATINGS, LISTINGS AND RELATED CONSTRUCTION DETAILS SEE 4. COLUMNS & PRIMARY STRUCTURAL FRAME MEMBERS SHALL BE PROVIDED WITH INDIVIDUAL ENCASEMENT FIRE PROTECTION AS REQUIRED BY CBC SECTIONS 704. - AD-28
- AD-28 TO TYPICAL INSULATION VALUES ROOF / CEILING INSULATION LOCATION R-30 VALUE METAL STUD EXTERIOR WALL R-?? - AD-28 INFORMATION ABOVE IS BASED ON ENERGY CALCULATIONS PROVIDED BY VCA GREEN, DATED 07/01/2021. GC TO VERIFY THE INFORMATION ABOVE IS CONSISTENT WITH THE MOST CURRENT ENERGY CALCULATIONS. WOOD STUD EXTERIOR WALL R-21 FIRE STOPPING LEGEND UL SERIES LISTING -- - - -
- - -
- - -- -- - PENETRATION DESCRIPTION ROUND BLANK OPENING RECTANGULAR BLANK OPNG BLANK OPNG WALL CHASE SINGLE PIPE PENETRATION MULTIPLE PIPE PEN SINGLE PIPE WALL CHASE DRAIN PER IN FLR BATH TUB PER IN FLR TOILET PEN IN FLOOR ROUND DUCT PENETRATION RECTANGULAR DUCT PEN CONC FLOORS CONC & MASONRY WALLS WOOD FRAME WALLS WOOD FRAME FLOORS C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-1000 C-AJ-1000 W-L-0000 W-L-0000 W-L-1000 W-L-1000 C-AJ-7000 C-AJ-7000 C-AJ-7000 C-AJ-7000 F-A-2000 F-A-1000 F-B-1000 W-L-7000 W-L-7000 F-C-0000 F-C-1000 F-C-8000 F-C-1000 F-C-2000 F-C-2000 F-C-7000 F-C-7000 2-HR FIRE BARRIER FRAMED ASSEMBLIES 3-HR HORIZONTAL SEPARATION SECTION LEGEND CONCRETE CMU ELEVATION KEYNOTES RETAIL STOREFRONT METAL GUARDRAIL EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 2 1/2" WIDE x 1 1/2" DEEP GLASS GUARDRAIL METAL CANOPY EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 6" WIDE x 1 1/2" DEEP 2.1 2133.145 SIGNAGE6 ART MURAL 7 TRELLIS8 FLAT CONCRETE ROOF TILE9 ADDRESS SIGN - SEE OCFA NOTES FOR MORE INFORMATION ELEVATION NOTES 1. ALL VERTICAL DIMENSIONS SHOWN ARE FROM THE TOP OF CONCRETE SLAB (WHERE OCCURS) OR TOP OF FLOOR SHT'G, U.N.O. VERIFY SLAB ELEVATION WITH CIVIL. 2. EXTEND AND RETURN FINISH MATERIALS AND COLORS TO INSIDE CORNERS, U.N.O. 3. U.N.O., PAINT EXPOSED METAL FLASHING & TRIM TO MATCH COLOR OF ADJACENT SURFACE. ALLOW FOR COLOR CHANGES ACROSS VARYING MATERIALS AND COLORS. 4. PROVIDE FLEXIBLE SEALED FLASHING AT ALL ITEMS PENETRATING EXTERIOR WALL CONSTRUCTION PER MANUFACTER'S RECOMMENDATIONS. 5. PROVIDE EXTERIOR WALL OPENING FLASHING PER 6. EXTEND SUBSTRATE SHEATHING TO NEAREST INSIDE OR OUTSIDE CORNER TO OBTAIN A FLUSH SUBSTRATE SURFACE. 7. DETERMINE GAUGE OF EXTERIOR METAL FRAMING BASED ON DEPTH, SPACING AND WIND LOADS INDICATED IN DRAWINGS. REFER TO STRUCTURAL DRAWINGS FOR WIND LOADS. 8. PROVIDE BLOCKING AND/OR APPROPRIATE BACKING FOR ALL RECESSED AND SURFACE-MOUNTED ITEMS. VERIFY LOCATIONS PRIOR TO CLOSURE OF FRAMING. 9. SIGNAGE: PROVIDE BLOCKING AND BACKING FOR SIGN MOUNTING. PROVIDE LOCKABLE ACCESS TO POWER AND SERVICE CONNECTIONS. VERIFY SIGN LOCATIONS PRIOR TO CLOSURE OF FRAMING. 10. ALIGN FINISH HEAD HEIGHT OF WINDOW AND PATIO DOOR TYPICAL AT ALL UNITS, U.N.O. GENERAL CONTRACTOR TO COORDINATE THIS REQUIREMENT WITH FRAMING SUB CONTRACTOR. 11. PROVIDE 5/8" TYPE X GYP. SHEATHING WHERE FIREWALL TERMINATES AT EXTERIOR WALL. 12. REFER TO COLOR BLOCKING AND/OR PAINTER'S EXHIBITS FOR FINAL COLOR AND FINISH SELECTIONS. 13. FOR PREFINISHED ITEMS, SUBMIT MANUFACTURER'S COLOR PALETTE TO ARCHITECT FOR REVIEW. ALL COLOR AND FINISH SELECTIONS, INCLUDING PREMIUM SELECTIONS, SHALL BE AVAILABLE FOR THE BID PRICE. 14. MOUNT ALL WALL LIGHT FIXTURES AT 6'- 8" MIN TO BOTTOM OF FIXTURE, U.N.O. 15. EXTERIOR FINISHES: SIZING, GAUGE, ATTACHMENTS, WRB, ASSOCIATED COMPONENTS AND GENERAL INSTALLATION SHALL BE CONSISTENT WITH MANUFACTURER'S RECOMMENDATIONS. 3 AD-26 24 AD-51.03 AD-51.1 22 AD-51.0 OR ELEVATION LEGEND EXTERIOR CEMENT PLASTER CONTROL JOINT. IN AREAS NOT ELEVATED, INSTALL TO SEGREGATE AREAS NOT EXCEEDING MORE THAN 144 SQ. FT. ON WALLS & NOT MORE THAN 100 SQ. FT. ON HORIZONTAL APPLICATIONS. DISTANCE BETWEEN JOINTS SHALL NOT EXCEED 18 FEET IN EITHER DIRECTION OR A LENGTH-TO-WIDTH RATIO OF 2.5 TO 1. HORIZONTAL JOINTS SHALL WRAP OUTSIDE CORNERS AND RETURN TO THE NEAREST INSIDE CORNER. FLOOR CONTROL / DRAINAGE JOINT IN EXTERIOR CEMENT PLASTER EXTERIOR CEMENT PLASTER: WITH 16/20 FINISH, PAINT WINDOW/DOOR TRIM: EPS 3 1/2 WIDE X 1 1/2" THICK, SMOOTH FINISH, TYP, U.N.O. EXHAUST TERMINATION - SEE MECH. PROVIDE MINIMUM DISTANCE OF 3' BETWEEN EXHAUST VENTS AND ANY OPENINGS INTO THE BUILDING SMOOTH FIBER CEMENT SIDING: CONDUCTOR HEAD & OVERFLOW, COLOR TO MATCH ADJACENT SURFACE 4" DIAMETER ALUMINUM DOWNSPOUT, COLOR TO MATCH ADJACENT SURFACE, U.N.O. EXPOSED CMU: W/ 2" THICK MATCHING CAP AT TOP OF WALL GROUT: CONCAVE PROFILE EXPOSED CONCRETE EXTERIOR CEMENT PLASTER: O/ WRB WITH SMOOTH HARD TROWELED FINISH & PAINT - AD-51.0- AD-51.0 ADHERED MASONRY VENEER: 11 AD-51.0 11 AD-51.0 22 AD-61.0- AD-XX- AD-51.0 14 AD-61.0 GFRC WAINSCOT:
- AD-20 PENETRATIONS OF FIRE-RESISTIVE WALLS, FLOOR/CEILINGS AND ROOF/CEILINGS SHALL BE PROTECTED AS REQUIRED IN CBC SEC. 714. FOR ADDITIONAL INFORMATION, SEE WALL SECTION 'C' SCALE: 1/4"=1'-0" C
1 1 A
A
D
C
City Council 23 – 11212/6/2022 11'-9 1/8" 10'-1" 8'-11 1/2" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB AT RESTAURANT T.O.PL 3RD FL (PODIUM LEVEL) T.O. SLAB 4TH FL SUBFLOOR 5TH FL SUBFLOOR 6TH FL SUBFLOOR T.O.PL T.O.PL T.O.PL 2ND FL T.O. SLAB 122.66' FF 134.42' FF 144.50' FF HDR HDR HDR HDR 9'-1" 7TH FL SUBFLOOR T.O.PL HDR HDR HDR
9'-0" 8'-0" 8'-0" 8'-1" 8'-1" 8'-1" 8'-1"
E A2-42 RESTAURANT UNIT UNIT UNIT UNIT DECK DECK DECK DECK UNIT DECK
PROPERTY LINE
9 AD-21
1 AD-21 17 AD-21
4 AD-21 1-HR ROOF/CEILING1-HR FLOOR/CEILING 3-HR FLOOR/CEILING NON-RATED DECK/CEILING TYP. 21 F A2-42 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A WALL SECTIONS A2-42 WALL SECTION NOTES 1. STRUCTURAL MEMBERS SHOWN IN ARCHITECTURAL SECTIONS ARE DIAGRAMMATIC IN NATURE AND SHOULD NOT BE RELIED UPON AS AN ACTUAL REPRESENTATION OF STRUCTURAL MEMBERS. REFER TO STRUCTURAL DRAWINGS FOR SIZES AND SPECIFIC CONFIGURATION OF STRUCTURAL MEMBERS. 2. FOR FIRE RATINGS OF WALLS SEE SHEETS A0-11 THRU A0-25. 3. FOR ASSEMBLIES, FIRE RATINGS, LISTINGS AND RELATED CONSTRUCTION DETAILS SEE 4. COLUMNS & PRIMARY STRUCTURAL FRAME MEMBERS SHALL BE PROVIDED WITH INDIVIDUAL ENCASEMENT FIRE PROTECTION AS REQUIRED BY CBC SECTIONS 704. - AD-28
- AD-28 TO TYPICAL INSULATION VALUES ROOF / CEILING INSULATION LOCATION R-30 VALUE METAL STUD EXTERIOR WALL R-?? - AD-28 INFORMATION ABOVE IS BASED ON ENERGY CALCULATIONS PROVIDED BY VCA GREEN, DATED 07/01/2021. GC TO VERIFY THE INFORMATION ABOVE IS CONSISTENT WITH THE MOST CURRENT ENERGY CALCULATIONS. WOOD STUD EXTERIOR WALL R-21 FIRE STOPPING LEGEND UL SERIES LISTING --
- - -- - -
- - -- -- - PENETRATION DESCRIPTION ROUND BLANK OPENING RECTANGULAR BLANK OPNG BLANK OPNG WALL CHASE SINGLE PIPE PENETRATION MULTIPLE PIPE PEN SINGLE PIPE WALL CHASE DRAIN PER IN FLR BATH TUB PER IN FLR TOILET PEN IN FLOOR ROUND DUCT PENETRATION RECTANGULAR DUCT PEN CONC FLOORS CONC & MASONRY WALLS WOOD FRAME WALLS WOOD FRAME FLOORS C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-1000 C-AJ-1000 W-L-0000 W-L-0000 W-L-1000 W-L-1000 C-AJ-7000 C-AJ-7000 C-AJ-7000 C-AJ-7000 F-A-2000 F-A-1000 F-B-1000 W-L-7000 W-L-7000 F-C-0000 F-C-1000 F-C-8000 F-C-1000 F-C-2000 F-C-2000 F-C-7000 F-C-7000 2-HR FIRE BARRIER FRAMED ASSEMBLIES 3-HR HORIZONTAL SEPARATION SECTION LEGEND CONCRETE CMU ELEVATION KEYNOTES RETAIL STOREFRONT METAL GUARDRAIL EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 2 1/2" WIDE x 1 1/2" DEEP GLASS GUARDRAIL METAL CANOPY EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 6" WIDE x 1 1/2" DEEP 2.12 133.145 SIGNAGE6 ART MURAL 7 TRELLIS8 FLAT CONCRETE ROOF TILE9 ADDRESS SIGN - SEE OCFA NOTES FOR MORE INFORMATION ELEVATION NOTES 1. ALL VERTICAL DIMENSIONS SHOWN ARE FROM THE TOP OF CONCRETE SLAB (WHERE OCCURS) OR TOP OF FLOOR SHT'G, U.N.O. VERIFY SLAB ELEVATION WITH CIVIL. 2. EXTEND AND RETURN FINISH MATERIALS AND COLORS TO INSIDE CORNERS, U.N.O. 3. U.N.O., PAINT EXPOSED METAL FLASHING & TRIM TO MATCH COLOR OF ADJACENT SURFACE. ALLOW FOR COLOR CHANGES ACROSS VARYING MATERIALS AND COLORS. 4. PROVIDE FLEXIBLE SEALED FLASHING AT ALL ITEMS PENETRATING EXTERIOR WALL CONSTRUCTION PER MANUFACTER'S RECOMMENDATIONS. 5. PROVIDE EXTERIOR WALL OPENING FLASHING PER 6. EXTEND SUBSTRATE SHEATHING TO NEAREST INSIDE OR OUTSIDE CORNER TO OBTAIN A FLUSH SUBSTRATE SURFACE. 7. DETERMINE GAUGE OF EXTERIOR METAL FRAMING BASED ON DEPTH, SPACING AND WIND LOADS INDICATED IN DRAWINGS. REFER TO STRUCTURAL DRAWINGS FOR WIND LOADS. 8. PROVIDE BLOCKING AND/OR APPROPRIATE BACKING FOR ALL RECESSED AND SURFACE-MOUNTED ITEMS. VERIFY LOCATIONS PRIOR TO CLOSURE OF FRAMING. 9. SIGNAGE: PROVIDE BLOCKING AND BACKING FOR SIGN MOUNTING. PROVIDE LOCKABLE ACCESS TO POWER AND SERVICE CONNECTIONS. VERIFY SIGN LOCATIONS PRIOR TO CLOSURE OF FRAMING. 10. ALIGN FINISH HEAD HEIGHT OF WINDOW AND PATIO DOOR TYPICAL AT ALL UNITS, U.N.O. GENERAL CONTRACTOR TO COORDINATE THIS REQUIREMENT WITH FRAMING SUB CONTRACTOR. 11. PROVIDE 5/8" TYPE X GYP. SHEATHING WHERE FIREWALL TERMINATES AT EXTERIOR WALL. 12. REFER TO COLOR BLOCKING AND/OR PAINTER'S EXHIBITS FOR FINAL COLOR AND FINISH SELECTIONS. 13. FOR PREFINISHED ITEMS, SUBMIT MANUFACTURER'S COLOR PALETTE TO ARCHITECT FOR REVIEW. ALL COLOR AND FINISH SELECTIONS, INCLUDING PREMIUM SELECTIONS, SHALL BE AVAILABLE FOR THE BID PRICE. 14. MOUNT ALL WALL LIGHT FIXTURES AT 6'- 8" MIN TO BOTTOM OF FIXTURE, U.N.O. 15. EXTERIOR FINISHES: SIZING, GAUGE, ATTACHMENTS, WRB, ASSOCIATED COMPONENTS AND GENERAL INSTALLATION SHALL BE CONSISTENT WITH MANUFACTURER'S RECOMMENDATIONS. 3 AD-26 24 AD-51.03 AD-51.1 22 AD-51.0 OR ELEVATION LEGEND EXTERIOR CEMENT PLASTER CONTROL JOINT. IN AREAS NOT ELEVATED, INSTALL TO SEGREGATE AREAS NOT EXCEEDING MORE THAN 144 SQ. FT. ON WALLS & NOT MORE THAN 100 SQ. FT. ON HORIZONTAL APPLICATIONS. DISTANCE BETWEEN JOINTS SHALL NOT EXCEED 18 FEET IN EITHER DIRECTION OR A LENGTH-TO-WIDTH RATIO OF 2.5 TO 1. HORIZONTAL JOINTS SHALL WRAP OUTSIDE CORNERS AND RETURN TO THE NEAREST INSIDE CORNER. FLOOR CONTROL / DRAINAGE JOINT IN EXTERIOR CEMENT PLASTER EXTERIOR CEMENT PLASTER: WITH 16/20 FINISH, PAINT WINDOW/DOOR TRIM: EPS 3 1/2 WIDE X 1 1/2" THICK, SMOOTH FINISH, TYP, U.N.O. EXHAUST TERMINATION - SEE MECH. PROVIDE MINIMUM DISTANCE OF 3' BETWEEN EXHAUST VENTS AND ANY OPENINGS INTO THE BUILDING SMOOTH FIBER CEMENT SIDING: CONDUCTOR HEAD & OVERFLOW, COLOR TO MATCH ADJACENT SURFACE 4" DIAMETER ALUMINUM DOWNSPOUT, COLOR TO MATCH ADJACENT SURFACE, U.N.O. EXPOSED CMU: W/ 2" THICK MATCHING CAP AT TOP OF WALL GROUT: CONCAVE PROFILE EXPOSED CONCRETE EXTERIOR CEMENT PLASTER: O/ WRB WITH SMOOTH HARD TROWELED FINISH & PAINT - AD-51.0- AD-51.0 ADHERED MASONRY VENEER: 11 AD-51.0 11 AD-51.0 22 AD-61.0- AD-XX- AD-51.0 14 AD-61.0 GFRC WAINSCOT:
- AD-20 PENETRATIONS OF FIRE-RESISTIVE WALLS, FLOOR/CEILINGS AND ROOF/CEILINGS SHALL BE PROTECTED AS REQUIRED IN CBC SEC. 714. FOR ADDITIONAL INFORMATION, SEE WALL SECTION 'F' SCALE: 1/4"=1'-0" F WALL SECTION 'E' SCALE: 1/4"=1'-0"
E
A
E
A
F
City Council 23 – 11312/6/2022 GA2-43 UNIT UNIT UNIT UNIT DECK DECK DECK PATIO UNIT DECK 9'-1 19/128" 9'-1" 9'-1" 9'-1" 9'-1" 1ST FL T.O. SLAB ON GRADE T.O.PL 3RD FL SUBFLOOR 4TH FL SUBFLOOR 5TH FL SUBFLOOR ROOF SHT'G. T.O.PL T.O.PL 2ND FL SUBFLOOR 124.70' FF T.O.PL. T.O.PL. HDR HDR HDR HDR HDR 8'-0 19/128" 8'-1" 8'-1" 8'-1" 8'-1"
9 AD-21
1 AD-21
4 AD-21 1-HR ROOF/CEILING 1-HR FLOOR/CEILING NON-RATED DECK/CEILING TYP. 2 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING A WALL SECTIONS A2-43 BUILDING # WALL SECTION NOTES 1. STRUCTURAL MEMBERS SHOWN IN ARCHITECTURAL SECTIONS ARE DIAGRAMMATIC IN NATURE AND SHOULD NOT BE RELIED UPON AS AN ACTUAL REPRESENTATION OF STRUCTURAL MEMBERS. REFER TO STRUCTURAL DRAWINGS FOR SIZES AND SPECIFIC CONFIGURATION OF STRUCTURAL MEMBERS. 2. FOR FIRE RATINGS OF WALLS SEE SHEETS A0-11 THRU A0-25. 3. FOR ASSEMBLIES, FIRE RATINGS, LISTINGS AND RELATED CONSTRUCTION DETAILS SEE 4. COLUMNS & PRIMARY STRUCTURAL FRAME MEMBERS SHALL BE PROVIDED WITH INDIVIDUAL ENCASEMENT FIRE PROTECTION AS REQUIRED BY CBC SECTIONS 704. - AD-28
- AD-28 TO TYPICAL INSULATION VALUES ROOF / CEILING INSULATION LOCATION R-30 VALUE METAL STUD EXTERIOR WALL R-?? - AD-28 INFORMATION ABOVE IS BASED ON ENERGY CALCULATIONS PROVIDED BY VCA GREEN, DATED 07/01/2021. GC TO VERIFY THE INFORMATION ABOVE IS CONSISTENT WITH THE MOST CURRENT ENERGY CALCULATIONS. WOOD STUD EXTERIOR WALL R-21 FIRE STOPPING LEGEND UL SERIES LISTING --
- - -- - -
- - -- -- - PENETRATION DESCRIPTION ROUND BLANK OPENING RECTANGULAR BLANK OPNG BLANK OPNG WALL CHASE SINGLE PIPE PENETRATION MULTIPLE PIPE PEN SINGLE PIPE WALL CHASE DRAIN PER IN FLR BATH TUB PER IN FLR TOILET PEN IN FLOOR ROUND DUCT PENETRATION RECTANGULAR DUCT PEN CONC FLOORS CONC & MASONRY WALLS WOOD FRAME WALLS WOOD FRAME FLOORS C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-0000 C-AJ-1000 C-AJ-1000 W-L-0000 W-L-0000 W-L-1000 W-L-1000 C-AJ-7000 C-AJ-7000 C-AJ-7000 C-AJ-7000 F-A-2000 F-A-1000 F-B-1000 W-L-7000 W-L-7000 F-C-0000 F-C-1000 F-C-8000 F-C-1000 F-C-2000 F-C-2000 F-C-7000 F-C-7000 2-HR FIRE BARRIER FRAMED ASSEMBLIES 3-HR HORIZONTAL SEPARATION SECTION LEGEND CONCRETE CMU ELEVATION KEYNOTES RETAIL STOREFRONT METAL GUARDRAIL EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 2 1/2" WIDE x 1 1/2" DEEP GLASS GUARDRAIL METAL CANOPY EPS TRIM BAND OVER EXTERIOR CEMENT PLASTER BROWN COAT- 6" WIDE x 1 1/2" DEEP 2.12 133.145 SIGNAGE6 ART MURAL 7 TRELLIS8 FLAT CONCRETE ROOF TILE9 ADDRESS SIGN - SEE OCFA NOTES FOR MORE INFORMATION ELEVATION NOTES 1. ALL VERTICAL DIMENSIONS SHOWN ARE FROM THE TOP OF CONCRETE SLAB (WHERE OCCURS) OR TOP OF FLOOR SHT'G, U.N.O. VERIFY SLAB ELEVATION WITH CIVIL. 2. EXTEND AND RETURN FINISH MATERIALS AND COLORS TO INSIDE CORNERS, U.N.O. 3. U.N.O., PAINT EXPOSED METAL FLASHING & TRIM TO MATCH COLOR OF ADJACENT SURFACE. ALLOW FOR COLOR CHANGES ACROSS VARYING MATERIALS AND COLORS. 4. PROVIDE FLEXIBLE SEALED FLASHING AT ALL ITEMS PENETRATING EXTERIOR WALL CONSTRUCTION PER MANUFACTER'S RECOMMENDATIONS. 5. PROVIDE EXTERIOR WALL OPENING FLASHING PER 6. EXTEND SUBSTRATE SHEATHING TO NEAREST INSIDE OR OUTSIDE CORNER TO OBTAIN A FLUSH SUBSTRATE SURFACE. 7. DETERMINE GAUGE OF EXTERIOR METAL FRAMING BASED ON DEPTH, SPACING AND WIND LOADS INDICATED IN DRAWINGS. REFER TO STRUCTURAL DRAWINGS FOR WIND LOADS. 8. PROVIDE BLOCKING AND/OR APPROPRIATE BACKING FOR ALL RECESSED AND SURFACE-MOUNTED ITEMS. VERIFY LOCATIONS PRIOR TO CLOSURE OF FRAMING. 9. SIGNAGE: PROVIDE BLOCKING AND BACKING FOR SIGN MOUNTING. PROVIDE LOCKABLE ACCESS TO POWER AND SERVICE CONNECTIONS. VERIFY SIGN LOCATIONS PRIOR TO CLOSURE OF FRAMING. 10. ALIGN FINISH HEAD HEIGHT OF WINDOW AND PATIO DOOR TYPICAL AT ALL UNITS, U.N.O. GENERAL CONTRACTOR TO COORDINATE THIS REQUIREMENT WITH FRAMING SUB CONTRACTOR. 11. PROVIDE 5/8" TYPE X GYP. SHEATHING WHERE FIREWALL TERMINATES AT EXTERIOR WALL. 12. REFER TO COLOR BLOCKING AND/OR PAINTER'S EXHIBITS FOR FINAL COLOR AND FINISH SELECTIONS. 13. FOR PREFINISHED ITEMS, SUBMIT MANUFACTURER'S COLOR PALETTE TO ARCHITECT FOR REVIEW. ALL COLOR AND FINISH SELECTIONS, INCLUDING PREMIUM SELECTIONS, SHALL BE AVAILABLE FOR THE BID PRICE. 14. MOUNT ALL WALL LIGHT FIXTURES AT 6'- 8" MIN TO BOTTOM OF FIXTURE, U.N.O. 15. EXTERIOR FINISHES: SIZING, GAUGE, ATTACHMENTS, WRB, ASSOCIATED COMPONENTS AND GENERAL INSTALLATION SHALL BE CONSISTENT WITH MANUFACTURER'S RECOMMENDATIONS. 3 AD-26 24 AD-51.03 AD-51.1 22 AD-51.0 OR ELEVATION LEGEND EXTERIOR CEMENT PLASTER CONTROL JOINT. IN AREAS NOT ELEVATED, INSTALL TO SEGREGATE AREAS NOT EXCEEDING MORE THAN 144 SQ. FT. ON WALLS & NOT MORE THAN 100 SQ. FT. ON HORIZONTAL APPLICATIONS. DISTANCE BETWEEN JOINTS SHALL NOT EXCEED 18 FEET IN EITHER DIRECTION OR A LENGTH-TO-WIDTH RATIO OF 2.5 TO 1. HORIZONTAL JOINTS SHALL WRAP OUTSIDE CORNERS AND RETURN TO THE NEAREST INSIDE CORNER. FLOOR CONTROL / DRAINAGE JOINT IN EXTERIOR CEMENT PLASTER EXTERIOR CEMENT PLASTER: WITH 16/20 FINISH, PAINT WINDOW/DOOR TRIM: EPS 3 1/2 WIDE X 1 1/2" THICK, SMOOTH FINISH, TYP, U.N.O. EXHAUST TERMINATION - SEE MECH. PROVIDE MINIMUM DISTANCE OF 3' BETWEEN EXHAUST VENTS AND ANY OPENINGS INTO THE BUILDING SMOOTH FIBER CEMENT SIDING: CONDUCTOR HEAD & OVERFLOW, COLOR TO MATCH ADJACENT SURFACE 4" DIAMETER ALUMINUM DOWNSPOUT, COLOR TO MATCH ADJACENT SURFACE, U.N.O. EXPOSED CMU: W/ 2" THICK MATCHING CAP AT TOP OF WALL GROUT: CONCAVE PROFILE EXPOSED CONCRETE EXTERIOR CEMENT PLASTER: O/ WRB WITH SMOOTH HARD TROWELED FINISH & PAINT - AD-51.0- AD-51.0 ADHERED MASONRY VENEER: 11 AD-51.0 11 AD-51.0 22 AD-61.0- AD-XX- AD-51.0 14 AD-61.0 GFRC WAINSCOT:
- AD-20 PENETRATIONS OF FIRE-RESISTIVE WALLS, FLOOR/CEILINGS AND ROOF/CEILINGS SHALL BE PROTECTED AS REQUIRED IN CBC SEC. 714. FOR ADDITIONAL INFORMATION, SEE WALL SECTION 'G' SCALE: 1/4"=1'-0" G
A
G
City Council 23 – 11412/6/2022 1 2
1 5
9 10 13 16 18 19 23 B.1 H.8
L
L
M
M
N
N CORRIDOR VENTILATION SHAFT CORRIDOR VENTILATION SHAFT CORRIDOR VENTILATION SHAFT FEC SP SP FEC FEC FEC
1 2
1 5
9 10 13 16 18 19 23 B.1 H.8
L
L
M
M
N
N
1 2
1 5
9 10 13 16 18 19 23 B.1 H.8
L
L
M
M
N
N LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
ELEC LV LV
ELEC LV
ELEC
LV ELEC
LV
ELEC UP UP UP UP UP 14 15 17
BCE
FG
H
D
J
A
3 4
6 7
8 11 12 20 21 22
KH.9 H.7
AKE.8 H.3 B.1
R
W TRASH / LOADING UP 5%
UP 5% BIKE STORAGE ROOM FIRE PUMP ROOM BOOSTER PUMP ROOM VAN 130.82' 129.94' 131.70' 127.30' 126.70' 130.30' 126.70' 126.68' 126.70' 126.70' 126.70' 128.76' 126.70' 130.30' 130.30' 130.30' 131.84' 131.84' 131.84' 131.61' 130.17' 126.57' 126.00' 126.00' 126.68' 126.70' 126.07' 125.82' 126.70' 126.70' 126.70' 127.61' 127.13' 128.76' 127.30' 126.70' UP 5% UP 6.2% UP 2%
G MAILROOM PARCEL
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
FEC FEC
FEC TRASH VESTIBULE ELECTRICAL ROOM STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 LV ELEC MPOE IDF UP DN 6.5% UP DN UP UP DN 2% UP
G
G
DN 8%
DN 4.67%
ELEC UP DN 4.67% DN 4.67%
DN 4.67% STORAGE 239'-0" 38'-6" 9'-1" 2'-2" 12'-0" 1'-6" 2'-0" 29'-6" 1'-6" 28'-6" 30'-0" 30'-0" 31'-6" 13'-0" 3'-4" 6'-5" 36'-8" 18'-0" 8'-7" 1'-0 1/8" 244'-8 1/2"
7 1/2" 73'-2 1/2" 32'-0" 8'-9 1/2" 16'-0" 2'-3" 7'-4" 20'-5" 13'-6" 4'-0" 13'-4" 27'-3" 2'-11" 1'-2"3'-4" 6'-9" 239'-0" 51'-11" 26'-6" 6'-0" 36'-1" 46'-5" 39'-2" 6'-0" 26'-11" 6'-10" 31'-8" 13'-5" 20'-11" 10'-0" 2" 37'-6" 37'-8" 0" 18'-8" 15'-9" 244'-10 1/2"
9 1/2" 73'-2 1/2" 32'-0" 8'-9 1/2" 22'-8" 95'-2" 5'-6" 6'-9" 34'-8" 23'-10" 6" 36'-2" 29'-7" 53'-2" 2" 43'-0" 11'-6 1/2" 1'-0" 8'-9 1/2" 42'-10 1/2" 2" 40'-6" 2" 12'-7" 6'-5" UNIT 2.2P-R B102 A5-26 1 A2-61
2 A2-60
1 A2-60
2 A2-61 UNIT 0.2A B101 A5-02 UNIT 1.3B B104 A5-14 UNIT 1.1F-R B103 A5-12 UNIT 4.1L-R B105 A5-44 UNIT 4.2A-R B106 A5-45 UNIT 3.1A B107 A5-31 UNIT 2.2G-R B108 A5-25 UNIT 1.1G B109 A5-12 UNIT 1.1H B110 A5-12 UNIT 4.2A B112 A5-45 UNIT 2.2L B114 A5-26 UNIT 3.2C B111 A5-32 UNIT 2.3A B113 A5-27 333
3333
3 33 3 3
3 4
4 4 4 4 4
4 4
44 4
11'-10"
1 A2-62 2 A2-62
3 A2-62 B101 B102 B103 B104 B105 B106 B107 B108 B109 B110 B111 B112 B113 B114 B115 B116 B117 B118 B120 B121 B122 B123 B124 B126 B125 B127 B128 B129 B119 1 A5-84
1 A5-82
1 A5-80
1 A5-78
2 A5-641 A5-92
1 A5-96
1'-0" 20'-6" 7'-7"
2'-6 1/2" 5'-6" 2'-7" 7'-0" 2'-7" 2" 23'-10" 6" 24'-0" 5'-6" 4 1/2" 1'-6" 25'-0" 6'-0" 19'-8 1/2" 2" 10'-7 1/2" 2" 12'-0" 2" 23'-10" 6" 23'-10" 10'-5" 20'-3" 21'-2" 8'-7 1/2" 10'-3 1/2" 6'-2 1/2" 1'-6"
1'-6" 5'-4"
9 9 10A 14
1 1 A2-70 A2-70
22 A2-70 A2-70 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B FIRST LEVEL FLOOR PLAN A2-51 BUILDING COMPOSITE PLAN NOTES 6 AD-31 1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. 2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE LEGAL ADDRESS. 3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE 4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. 6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON 7. THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY 8. WITH CBC 803. 9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. 10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATED ACCESS PANELS WITH SELF CLOSING DEVICES. 11. PROVIDE ACOUSTICAL ASSEMBLIES PER 12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. 13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER 14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. 15. SEE STRUCTURAL DRAWINGS FOR: A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING B) SPECIAL NAILING AND BLOCKING REQUIREMENTS 15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE VENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER PROTECTION SHALL BE EXTENDED TO THOSE AREAS. 16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED AND APPROVED. 17. PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTION THROUGHOUT. 18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) 19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE PROTECTION PER 20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FOR SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. 21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR SECURITY AND SAFETY. 22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. - AD-XX ALL AD-02.1 ALL AD-01 TO KEYNOTES MECHANICAL SHAFT - SEE MECHANICAL DWGS LINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF, SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH LOCAL FIRE AUTHORITY. BUILDING PLAN LEGEND DOOR SYMBOL FLOOR DRAIN - SEE PLMB XX WINDOW & STOREFRONT SYMBOL - A7-20
- A7-40 X FEC AD-XX DS DOWNSPOUT
X AD-XX WATERPROOF TRAFFIC COATING FD DIRECTION OF SLOPE - 1/4" / FT U.N.O.
X AD-XX 3-HR RATED FIRE WALL CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) ALL AD-20 18 AD-22 12 - A7-10
- A7-30 ACCESSIBLE PARKING SPACE
X AD-XXX AD-XX WATERPROOF TRAFFIC COATING FRAMED WALL - 6" METAL STUD CONCRETE COLUMN MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. FULL HEIGHT STEEL FENCING -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" 16 AD-31 40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEX AD-XX FRAMED WALL - 3-5/8" METAL STUD AIRCRAFT CABLE VEHICULAR BARRIER SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB -6" TOC X AD-XX CONCRETE WHEEL STOP DETECTABLE WARNINGS, MIN 36" WIDEX AD-XX CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) COLUMN CAP CMU WALL - SEE STRUCTURAL FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB CONCRETE WALL - SEE STRUCTURAL CONCRETE STRUCTURAL SLAB TRANSITIONS 3 RETAIL PARKING SPACE4 GUEST PARKING SPACE5 EV READY SPACE (FUTURE) 6 EV CHARGING SPACE (INSTALLED),REFER TO DETAIL 9/AD-31 7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR 10 3 AD-31 12 AD-31 11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 12 AD-01 12 EXPANSION JOINT, REFER TO SHEET AD-33 2-HR RATED FIRE BARRIER STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF CONCRETE SLAB ABOVE. 1314 DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB BUILDING B FIRST FLOOR PLAN SCALE: 3/32"=1'-0" 1 N
City Council 23 – 11512/6/2022
CORRIDOR VENTILATION SHAFT CORRIDOR VENTILATION SHAFT CORRIDOR VENTILATION SHAFT FEC SP SP FEC FEC FEC
1 2
1 5
9 10 13 16 18 19 23 B.1 H.8
L
L
M
M
N
N
1 2
1 5
9 10 13 16 18 19 23 B.1 H.8
L
L
M
M
N
N LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
ELEC LV LV
ELEC LV
ELEC
LV ELEC
LV
ELEC UP UP UP UP UP 14 15 17
BCE
FG
H
D
J
A
3 4
6 7
8 11 12 20 21 22
KH.9 H.7
AKE.8 H.3 B.1
R
W TRASH / LOADING UP 5%
UP 5% BIKE STORAGE ROOM FIRE PUMP ROOM BOOSTER PUMP ROOM VAN 130.82' 129.94' 131.70' 127.30' 126.70' 130.30' 126.70' 126.68' 126.70' 126.70' 126.70' 128.76' 126.70' 130.30' 130.30' 130.30' 131.84' 131.84' 131.84' 131.61' 130.17' 126.57' 126.00' 126.00' 126.68' 126.70' 126.07' 125.82' 126.70' 126.70' 126.70' 127.61' 127.13' 128.76' 127.30' 126.70' UP 5% UP 6.2% UP 2%
G MAILROOM PARCEL
ñ
ñ
ñ ñ
ñ
ñ
ñ ñ
ñ
ñ
ñ
ñ
FEC FEC
FEC TRASH VESTIBULE ELECTRICAL ROOM STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 LV ELEC MPOE IDF UP DN 6.5% UP DN UP UP DN 2% UP
G
G
DN 8%
DN 4.67%
ELEC UP DN 4.67% DN 4.67%
DN 4.67% STORAGE 126.00' TSS 126.00' 126.70' 126.70' 125.07' 126.00' 126.00' 126.70' TSS 126.70' TSS 126.70' 124.42' DN 1.5% 124.30' 124.42' 1% 1% 125.86'124.27' 126.55' 124.26' 1.1% 1% 1%
1% 126.61' 124.95' 126.61' 124.95' 126.70' TSS 126.70' 126.70' 125.57' 126.70' 125.57' 126.70' T.CURB 1%1% 1 A2-61
2 A2-60
1 A2-60
2 A2-611 1 A2-70 A2-70
22 A2-70 A2-70 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B FIRST LEVEL SLAB PLAN A2-51S BUILDING B FD FLOOR DRAIN KEYPLAN SLAB PLAN NOTES SYMBOL LEGEND DIRECTION OF SLOPE - 1/4" / FT U.N.O. CONCRETE SLAB ON GRADE OR ELEVATED CONCRETE SLAB DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE CONCRETE TOPPING SLAB. 4" DEPRESSION FROM TOP OF SLOPE (WHERE OCCURS), TYP. U.N.O. CONCRETE SLAB ON GRADE PER LANDSCAPE CONCRETE SLAB OVER STRUCTURAL FOAM - SEE STRUCTURAL FOR ADDITIONAL INFORMATION 1. TYPICAL DIMENSIONS ARE PROVIDED ON ARCHITECTURAL FLOORPLANS. ADDITIONAL DIMENSIONS ON SLAB PLAN ARE TO FACE OF CONCRETE, TYP, U.N.O. SEE "SLAB & FRAMING ALIGNMENT" DETAIL BELOW. 2. SEE CIVIL PLANS FOR FINISH SURFACE ELEVATIONS OF CONCRETE SLABS, TYP. 3. AT GARAGES, MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE - SEE FLOORPLANS. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. COORDINATE ALL UTILITIES, FIXTURES, SUPPORTS, ETC. ACCORDINGLY. 4. REFER TO STRUCTURAL, MECHANICAL, PLUMBING AND ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION. IT IS THE CONCRETE CONTRACTOR'S RESPONSIBILITY TO IDENTIFY ANY DISCREPANCY PRIOR TO THE POUR AND NOTIFY THE GENERAL CONTRACTOR AND ARCHITECT FOR CORRECTIVE MEASURES. 5. PROVIDE CONCRETE BLOCKOUT AT TUB DRAINS. 6. PRIOR TO REQUESTING A FOUNDATION INSPECTION, GEOTECHNICAL CONSULTANT SHALL REVIEW AND APPROVE THE FOUNDATION EXCAVATIONS. 7. PROVIDE PENETRATION FIRESTOP SYSTEMS PER 8. AT DEPRESSED AREAS, SLOPES INIDCATED SHALL APPLY TO BOTH FINISH SURFACE AND CONCRETE SUBSTRATE, TYP. U.N.O. 9. PROVIDE VAPOR BARRIER BELOW ON-GRADE SLABS WHERE MOISTURE-SENSITIVE FLOOR COVERINGS OCCUR OR AS OTHERWISE RECOMMENDED BY GEOTECHNICAL ENGINEER - SEE GEOTECH REPORT. 10. ADDITIONAL EMBED PLATES MAY OCCUR - SEE STRUCTURAL AND LANDSCAPE DRAWINGS FOR LOCATIONS AND ADDITIONAL REQUIREMENTS. COORDINATE ANY DESIGN / BUILD ELEMENTS THAT MAY REQUIRE EMBED PLATES. 11. STRUCTURAL STEEL BASE PLATES AND FASTENERS ARE INTENDED TO SIT AT OR BELOW THE TOP OF CONCRETE SO AS NOT TO INTERUPT FINISH FLOORING. SEE STRUCTURAL DRAWINGS AND COORDINATE ASSOCIATED TRADES ACCORDINGLY. -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" CONCRETE STRUCTURAL SLAB TRANSITIONS SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB SLAB & FRAMING ALIGNMENT CONCRETE CURB OR STEM WALL, 8" MIN WIDTH, U.N.O. - SEE CIVIL AND STRL FOR ADDITIONAL INFORMATION
X AD-XX
X AD-XX FD 2 STAGE FLOOR DRAIN
X AD-XXX AD-XX -6" TOC DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE WATERPROOF TRAFFIC COATING. 1/2" DEPRESSION AT TOP OF SLOPE (WHERE OCCURS), TYP, U.N.O. DEPRESSED CONCRETE STRUCTURAL SLAB TO RECEIVE DECORATIVE PAVING PER LANDSCAPE. 6" DEPRESSION AT TOP OF SLOPE (WHERE OCCURS) U.N.O. TOOLED CONTROL JOINT IN CONCRETE TOPPING SLAB CONCRETE SLAB OPENINGX AD-XXX AD-XXX AD-XXX AD-XXX AD-XX ALIGN SUBSTRATES TO ALLOW FLUSH EXTERIOR FINISH. GC TO COORDINATE WITH ARCHITECT. EXTERIOR FINISH ALIGN EXTERIOR FINISH MULTIPLE LAYERS OF SHT'G AND/OR FURRING MAY OCCUR - SEE ARCH AND STRL PLANS IF SHT'G IS EXPOSED, PROTECT UNDERSIDE WITH GSM "Z" FLASHING OR SIMILAR APPROVED MATERIAL ALTERNATIVELY:PROVIDE SUITABLE FILL MATERIAL OR EXTEND CONCRETE SLAB TO ALIGN WITH EXTERIOR WALL SUBSTRATE. GC TO COORDINATE WITH ARCHITECT MULTIPLE LAYERS OF SHT'G AND/OR FURRING MAY OCCUR - SEE ARCH AND STRL PLANS TYP ELEVATED SLAB DIMENSION POINT PER FLOOR PLAN DIMENSION POINT PER FLOOR PLAN
B TYP SLAB ON GRADE
A WALL ASSEMBLY PER PLAN WALL ASSEMBLY PER PLAN
N BUILDING B FIRST FLOOR SLAB PLAN SCALE: 3/32"=1'-0"
1 City Council 23 – 11612/6/2022 1 2
1 5
9 10 13 16 18 19 23 B.1 H.8
L
L
M
M
N
N CORRIDOR VENTILATION SHAFT CORRIDOR VENTILATION SHAFT CORRIDOR VENTILATION SHAFT IDF FEC SP SP FEC FEC
FEC STORAGE
1 2
1 5
9 10 13 16 18 19 23 B.1 H.8
L
L
M
M
N
N
1 2
1 5
9 10 13 16 18 19 23 B.1 H.8
L
L
M
M
N
N LV ELEC ELEC
LV LV ELEC ELEC
LV
LV ELEC
LV ELEC
LV ELEC
ELEC LV LV
ELEC
LV ELEC 14 15 17
BCE
FG
H
D
J
A
3 4
6 7
8 11 12 20 21 22
KH.9 H.7
AKE.8 H.3 B.1
R W G UP 5% RAMP UP 93' (RUN) (5% SLOPE) = 4.65' (RISE) UP 3.5% DN 5% OPEN TO BELOW VAN 142.39' 142.39' 136.34' 143.47' 137.89' 143.47' 136.34' 136.34' 137.89' 137.89' 136.20' 137.75' 136.34' 137.89' 142.39' 142.39' 143.47' 143.47' 143.24' 142.16' 137.89' 140.85' 140.85' UP 5% UP DN UP EV EV EV EV
EV
EV EV EV
ñ ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ
ñ ñ
FEC FEC
FEC FEC LV ELEC LV ELEC
LV ELEC STAIR B1 STAIR B2 STAIR B3 STAIR B4 ELEV. B1 ELEV. B2 IDF UPDN LV
ELEC UP UP DN DNUP TRASH VESTIBULE UNIT 2.2P-R B202 A5-26 1 A2-61
2 A2-60
1 A2-60
2 A2-61 UNIT 0.2A B201 A5-02 UNIT 2.1Q B204 A5-23 UNIT 1.1F-R B203 A5-12 UNIT 4.1M-R B205 A5-44 UNIT 4.2B-R B206 A5-45 UNIT 3.1B B207 A5-31 UNIT 2.2H-R B208 A5-25 UNIT 2.1J-R B209 A5-22 UNIT 1.1K B210 A5-12 UNIT 4.2B B212 A5-45 UNIT 2.2M B214 A5-26 UNIT 4.1N B211 A5-44 UNIT 2.3B B213 A5-27 6 66666
6 6 6 6
6 6
6 6 239'-0" 38'-6" 9'-1" 2'-2" 12'-0" 1'-6" 2'-0" 29'-6" 1'-6" 28'-6" 30'-0" 30'-0" 31'-6" 13'-0" 3'-4" 6'-5" 36'-8" 18'-0" 8'-7" 1'-0 1/8" 244'-8 1/2"
7 1/2" 73'-2 1/2" 32'-0" 8'-9 1/2" 16'-0" 2'-3" 7'-4" 20'-5" 13'-6" 4'-0" 13'-4" 27'-3" 2'-11" 1'-2"3'-4" 6'-9" 239'-0" 51'-11" 26'-6" 6'-0" 36'-1" 46'-5" 39'-2" 6'-0" 26'-11" 6'-10" 31'-8" 13'-5" 20'-11" 10'-0" 2" 37'-6" 37'-6" 2" 18'-8" 15'-9" 244'-10 1/2"
9 1/2" 73'-2 1/2" 32'-0" 8'-9 1/2" 22'-8" 95'-2" 5'-6" 6'-9" 34'-8" 23'-10" 6" 36'-2" 29'-7" 53'-2" 2" 43'-0" 11'-6 1/2" 1'-0" 10'-3 1/2" 42'-10 1/2" 2" 40'-6" 2" 12'-7" 6'-5"
11'-10"
1 A2-62
2 A2-62
3 A2-62 B201 B202 B203 B204 B205 B206 B208 B207 B209 B210 B211 B212 B213 1 1 A2-70 A2-70
22 A2-70 A2-70
2 A5-84
2 A5-82
2 A5-80
2 A5-78
2 A5-92
2 A5-96 COPYRIGHT C
It is the clients responsibility prior to or during construction to notify the architect in writing of any perceived errors or omissions in the plans and specifications of which a contractor thoroughly knowledgeable with the building codes and methods of construction should reasonably be aware. Written instructions addressing such perceived errors or omissions shall be received from the architect prior to the client or clients subcontractors proceeding with the work. The client will be responsible for any defects in construction if these procedures are not followed. Architecture + Planning 17911 Von Karman Ave. Suite 200 Irvine, CA 92614 ktgy.com 949.851.2133 License Stamp Project Contact: Email: Principal: Project Designer: Project Director: KTGY Project No: 2017-0934 Debbie Holland [email protected] Wil Wong D. Schoolmeester Debbie Holland Developer PHONE NO. 4199 CAMPUS DRIVE IRVINE, CA 92612 (714) 342-2502 415 & 515 E. 4TH STREET, SANTA ANA, CA 92701
4TH AND MORTIMER No. Date Description
08-01-2022 FIRST PLAN CHECK SUBMITTAL BUILDING B SECOND LEVEL FLOOR PLAN BUILDING B SECOND FLOOR PLAN SCALE: 3/32"=1'-0" 1 A2-52 BUILDING COMPOSITE PLAN NOTES
6 AD-31 1. THE BUILDING PLAN IS PROVIDED FOR PLAN TO PLAN RELATIONSHIPS, OVERALL BUILDING DIMENSIONS, ASSEMBLIES, DETAIL REFERENCES, DECK SLOPES, GUARDRAILS AND OTHER INFORMATION NOT SPECIFIC TO THE ENLARGED PLANS. SEE ENLARGED PLANS FOR ADDITIONAL INFORMATION. 2. UNIT NUMBERS HEREIN ARE PROVIDED FOR CONSTRUCTION PURPOSES ONLY. THIS NUMBER IS NOT THE LEGAL ADDRESS. 3. FOR GENERAL ACCESSIBILITY INFORMATION, SEE 4. ALL DIMENSIONS ARE TO THE FACE OF STUD, U.N.O. 5. OFFSET ALL IMMEDIATELY ADJACENT DOOR OPENINGS 4" FROM PERPENDICULAR WALL U.N.O. 6. PROVIDE PENETRATION FIRESTOP SYSTEMS PER LEGEND ON 7. THE FLAME-SPREAD RATING OF INTERIOR WALLS AND CEILING FINISH MATERIALS SHALL COMPLY 8. WITH CBC 803. 9. INTERIOR TRIMS SHALL COMPLY WITH CBC 806. 10. PROVIDE ALL NECESSARY CEILING OR WALL ACCESS PANELS AS REQUIRED FOR AIR CONDITIONING, PLUMBING, FIRE SPRINKLER AND ELECTRICAL SYSTEMS. IN FIRE-RATED ASSEMBLIES PROVIDE FIRE-RATED ACCESS PANELS WITH SELF CLOSING DEVICES. 11. PROVIDE ACOUSTICAL ASSEMBLIES PER 12. INTERIOR DECORATIVE MATERIAL AND TRIM SHALL COMPLY WITH CBC 806. 13. MOUNT ELECTRIC SWITCH AND OUTLET BOXES IN DEMISING WALLS PER 14. VERTICAL AND HORIZONTAL FIRE BLOCKING SHALL CONFORM TO CBC 718.2. 15. SEE STRUCTURAL DRAWINGS FOR: A) SIZE & LOCATION OF FRAMING AND PLYWOOD SHEATHING B) SPECIAL NAILING AND BLOCKING REQUIREMENTS 15. PROVIDE CROSS VENTILATION, AT A MINIMUM RATE OF 1/150, FOR ENCLOSED FRAMING IN EXTERIOR BALCONIES AND ELEVATED WALKING SURFACES THAT ARE EXPOSED TO RAIN, SNOW OR DRAINAGE FROM IRRIGATION. VENTILATION SHALL BE PROVIDED BY CONTINUOUS REMOVABLE SOFFIT VENTS, RUNNING PERPENDICULAR TO FRAMING MEMBERS, AT BOTH THE FRONT AND REAR OF JOIST SPACES TO BE VENTILATED. IN FIRE-RATED BALCONIES AND ELEVATED WALKING SURFACE ASSEMBLIES, SPRINKLER PROTECTION SHALL BE EXTENDED TO THOSE AREAS. 16. WHERE BALCONIES AND OTHER ELEVATED WALKING SURFACES ARE EXPOSED TO WATER, SNOW OR IRRIGATION AND THE STRUCTURAL FRAMING IS PROTECTED BY AN IMPERVIOUS MOISTURE BARRIER, ALL ELEMENTS OF THE IMPERVIOUS MOISTURE BARRIER SYSTEM SHALL NOT BE CONCEALED UNTIL INSPECTED AND APPROVED. 17. PARKING GARAGE TYPE-IA CONSTRUCTION. PROVIDE NON-COMBUSTIBLE FIRE-RESISTIVE CONSTRUCTION THROUGHOUT. 18. VEHICLE RAMPS UTILIZED FOR PARKING SHALL NOT EXCEED SLOPE OF 1:15 (6.67%) 19. FOR LOCATIONS WITHIN 10 FEET OF VEHICULAR TRAFFIC AND PARKING STALLS, PROVIDE PIPE PROTECTION PER 20. GC TO COORDINATE PLACEMENT OF STEEL EMBED PLATES AND FASTENERS AT UNDERSIDE OF SLAB FOR SUSPENSION OF PIPES, EQUIPMENT, DUCTWORK, ETC. 21. THE INTERIOR OF THE PARKING AREAS SHALL BE PAINTED WHITE AND CONTAIN SUFFICIENT LIGHTING FOR SECURITY AND SAFETY. 22. ALL AREAS ON ALL FLOORS OF PARKING GARAGES SHALL MAINTAIN A MINIMUM OF 8'-2" CLEAR HEIGHT FROM DRIVING SURFACE TO ANY AND ALL OBSTRUCTIONS. - AD-XX ALL AD-02.1 ALL AD-01 TO KEYNOTES MECHANICAL SHAFT - SEE MECHANICAL DWGS LINE OF FLOOR ABOVEFIRE EXTINGUISHER CABINET. TOP AT +48" MAX AFF, SEMI-RECESSED IN FRAMED WALLS. VERIFY FINAL LOCATIONS WITH LOCAL FIRE AUTHORITY. BUILDING PLAN LEGEND DOOR SYMBOL FLOOR DRAIN - SEE PLMB XX WINDOW & STOREFRONT SYMBOL - A7-20
- A7-40 X FEC AD-XX DS DOWNSPOUT
X AD-XX WATERPROOF TRAFFIC COATING FD DIRECTION OF SLOPE - 1/4" / FT U.N.O.
X AD-XX 3-HR RATED FIRE WALL CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) ALL AD-20 18 AD-22 12 - A7-10
- A7-30 ACCESSIBLE PARKING SPACE
X AD-XXX AD-XX WATERPROOF TRAFFIC COATING FRAMED WALL - 6" METAL STUD CONCRETE COLUMN MAINTAIN 8'-2" MIN. CLEAR AFF ALONG THE ENTIRE PATH TO AND FROM ACCESSIBLE PARKING, INCLUDING ADJACENT AISLE. MAINTAIN 7'-0" MIN CLEAR AFF IN ALL OTHER LOCATIONS OF GARAGE. FULL HEIGHT STEEL FENCING -X" DEPRESSION SLOPE TO LEVEL LEVEL TO SLOPE DEPRESSION TO SLOPE -X" 16 AD-31 40" HIGH CMU WALL W/ 3-5/8" METAL STUD ABOVEX AD-XX FRAMED WALL - 3-5/8" METAL STUD AIRCRAFT CABLE VEHICULAR BARRIER SPOT ELEVATION RELATIVE TO 0'-0" REFERENCE ELEVATION U.N.O. SEE CIVIL FOR ACTUAL FINISH FLOOR ELEVATIONS -3" FS FS = FINISH SURFACE TOC = TOP OF STRUCTURAL CONCRETE SLAB TO CURB = TOP OF CURB -6" TOC X AD-XX CONCRETE WHEEL STOP DETECTABLE WARNINGS, MIN 36" WIDEX AD-XX CONCRETE TOPPING SLAB (PROVIDE CONTROL JOINTS AT CORNERS AND MAX. 5'-0" O.C. U.N.O.) COLUMN CAP CMU WALL - SEE STRUCTURAL FRAMED WALL - 6" METAL STUD OVER 6" x 6" CONCRETE CURB CONCRETE WALL - SEE STRUCTURAL CONCRETE STRUCTURAL SLAB TRANSITIONS 3 RETAIL PARKING SPACE4 GUEST PARKING SPACE5 EV READY SPACE (FUTURE) 6 EV CHARGING SPACE (INSTALLED),REFER TO DETAIL 9/AD-31 7 CLEAN AIR VEHICLE PARKING SPACE, REFER TO DETAIL 9/AD-31 8 42" TALL BOLLARD, SEE STRUCTURAL AND DETAIL 2/AD-31 9 ACCESSIBLE PARKING SPACE, REFER TO DETAILS 5, 6, & 9/AD-01 AND 10/AD-31 VEHICULAR HEADOOM CLEARANCE BAR, REFER TO DETAIL 1/AD-31 A. MOUNT BOTTOM OF BAR AT 8'-2" ABOVE FINISH FLOOR B. MOUNT BOTTOM OF BAR AT 7'-0" ABOVE FINISH FLOOR 10 3 AD-31 12 AD-31 11 DIAGONAL STRIPING, REFER TO DETAIL 6/AD-01 12 AD-01 12 EXPANSION JOINT, REFER TO SHEET AD-33 2-HR RATED FIRE BARRIER STEEL STUD AND GYPSUM BOARD PARTITION WALLS BETWEEN INDIVIDUAL STORAGE SPACES. PARTITION WALLS SHALL BE 7'-0" HIGH, WITH CHAIN LINK FENCING EXTENDING FROM TOP OF WALL TO UNDERSIDE OF CONCRETE SLAB ABOVE. 1314 DIRECTIONAL ARROWS PAINTED ON CONCRETE SLAB N
City Council 23 – 11712/6/2022 1 2
1 5
9 10 13 16 18 19 23 B.1 H.8
L
L
M
M