Cities Index.
Agenda packet

Santa Cruz City Council
November 29, 2022

Document
Agenda packet
Meeting
November 29, 2022
Body
Santa Cruz City Council
Pages
9
Original file
144.5 MB
Text extracted from the city's file for reading and search. Open the original on ecm.cityofsantacruz.com. That file is the official record.

CITY OF SANTA CRUZ
809 Center Street
Santa Cruz, California 95060

CITY COUNCIL AGENDA
Special Meeting – November 29, 2022
4:00 p.m. CONSENT, GENERAL BUSINESS, AND PUBLIC HEARING, ZOOM/COUNCIL

CHAMBERS
IMPORTANT NOTICE:

Pursuant to California Government Code 54953(e)(1)(A) and (C), and the City of Santa Cruz’s resolution authorizing continued virtual participation in public meetings given the COVID-19 pandemic, meetings of the Santa Cruz City Council are being conducted with a hybrid format, providing both in-person and virtual participation in order to promote social distancing and protect the health and safety of attendees, staff, and Councilmembers.

In order to minimize exposure to COVID-19, the meeting may be viewed remotely, using any of the following sources:
 Click on Zoom link (no time delay): https://zoom.us/j/94684401344  Online at http://www.cityofsantacruz.com/government/city-council/council-meetings  Online at Watch – Community Television of Santa Cruz County  Comcast Channel 25
Or: Call any of the numbers below. If one is busy, try the next one.  1-833-548-0276 (Toll Free)
 1-833-548-0282 (Toll Free)
 1-877-853-5247 (Toll Free)
 1-669-900-9128
 Enter the meeting ID number: 946 8440 1344
 When prompted for a Participant ID, press #.
 Press *9 on your phone to “raise your hand” when the Mayor calls for public comment.  It will be your turn to speak when the Mayor calls on you. Press *6 to unmute yourself. The timer will then be set.

Correspondence to be included in the agenda packet must be received by 12:00 pm on Tuesday, November 29th
The City of Santa Cruz does not discriminate against persons with disabilities. Out of consideration for people with chemical sensitivities we ask that you attend fragrance free. Upon request, the agenda can be provided in a format to accommodate special needs. Additionally, if you wish to attend this public meeting and will require assistance such as an interpreter for American Sign Language, Spanish, or other special equipment, please call the City Clerk’s Department at 420-5030 at least five days in advance so that we can arrange for such special assistance, or email [email protected]. The Cal-Relay system number: 1-800-735-2922.

Si desea asistir a esta reunión pública y necesita ayuda - como un intérprete de lenguaje de señas americano, español u otro equipo especial - favor de llamar al Departamento de la Secretaría de la Ciudad al 420-5030 al menos cinco días antes para que podamos coordinar dicha asistencia especial o envié un correo electrónico a [email protected]. El número del sistema Cal-Relay es: 1-800-735-2922. 11/29/2022 City Council Special Meeting 2
PLEASE NOTE:

Requests for extra speaking time must be made by 5:00 p.m. on Sunday, November 27th by emailing the Mayor and the City Clerk. Approval will be confirmed via email. [email protected] [email protected]
The City of Santa Cruz does not discriminate against persons with disabilities. Out of consideration for people with chemical sensitivities we ask that you attend fragrance free. Upon request, the agenda can be provided in a format to accommodate special needs. Additionally, if you wish to attend this public meeting and will require assistance such as an interpreter for American Sign Language, Spanish, or other special equipment, please call the City Clerk’s Department at 420-5030 at least five days in advance so that we can arrange for such special assistance, or email [email protected]. The CalRelay system number: 1-800-735-2922.

Si desea asistir a esta reunión pública y necesita ayuda - como un intérprete de lenguaje de señas americano, español u otro equipo especial - favor de llamar al Departamento de la Secretaría de la Ciudad al 420-5030 al menos cinco días antes para que podamos coordinar dicha asistencia especial o envié un correo electrónico a [email protected]. El número del sistema Cal-Relay es: 1-800-735-2922.

City Council Special Meeting
4:00 P.M.

Call to Order
Roll Call
Consent Agenda

1. City Council and Community Support of UC Academic Worker Strike and “Fair UC Now” Bargaining Requests (CN)
Motion to direct the Mayor to write a letter on behalf of the City Council and Santa Cruz community to the University of California (UC) Regents, the ‘Fair UC Now’ and UC Regents bargaining teams, and UC President Michael V. Drake to acknowledge how difficult it is for UC graduate students and UC workers to afford to live in communities across the state of California where the cost of rent far outstrips their salaries; express the Santa Cruz City Council and community support of the current UAW 5810, UAW 2865, and SRU-UAW Postdoc, Academic Researcher, Graduate Student Researcher, Trainees, Fellows, Graduate Student Instructors, Readers and Tutors strike and the students’ bargaining proposal as presented in the campaign “Fair UC Now”; and urge the UC Regents to find an immediate remedy and resolution.
11/29/2022 City Council Special Meeting 3
Consent Agenda (continued)

2. Purchase of Type 1 Fire Engine (FD)
Motion to:
1) Adopt a resolution amending the FY 2023 budget to transfer $850,000 from the City of Santa Cruz Capital Investment Program (CIP) to FY 2023 Fire Department Capital CIP budget number c212315; and 2) Approve the purchase of a type 1 Fire Engine, using Project c212315, in the amount of $850,000.00 from Golden State Fire Apparatus.

General Business
Please note: members of the City’s Water Commission have been invited to attend this meeting for the below item. This is not a joint Water Commission/City Council meeting.

3. Securing Our Water Future Resolution and Policy Guidance for Water Supply Augmentation to Improve Water Supply Reliability for Santa Cruz Water Service Customers (WT)
Motion to:
1) Adopt a resolution establishing a policy on Securing Our Water Future that provides guidance and direction for the development and implementation of water supply augmentation projects needed to resolve Santa Cruz’s long-standing water supply reliability issue; and 2) Direct staff to add the policy direction included in the Securing Our Water Future resolution to the City Council’s Policy Manual as policy

34.7, Securing Our Water Future Policy Guidance for Water Supply Augmentation to Address Santa Cruz’s Water Supply Reliability Issue. 11/29/2022 City Council Special Meeting 4
Public Hearing

4. Appeal of Planning Commission Approval of CP20-0068 Located at 126 Eucalyptus Avenue & 136 Pelton and Including a Non Residential Demolition Authorization Permit, Sequential Lot Line Adjustment, Special Use Permit, Coastal Permit, Design Permit, and Heritage Tree Removal Permit to Reconfigure Five Lots into Two, Demolish Two Existing School Buildings (Approximately 28,417 Square Feet), Remove Six Heritage Trees, and Construct a 76-Unit (Including 13 Full Dwelling Units) Senior Housing Facility on a Site Listed on the Historic Building Survey (Vol. 1, p. 39) in the R 1 5/WCD O/CZ O/SP O (Single family residence/West Cliff Drive Overlay/Coastal Zone Overlay/Shoreline Protection Overlay) Zone District. (Environmental Determination:

Categorical Exemption; Exempt under PRC CEQA Section 21083.3) Applicant: Roger Bernstein, Filed 8/10/2020 (PL)
Resolution denying the appeal of Anne and Robert Segal and upholding the appeal of Roger Bernstein, thereby adopting the resolution approving the Non-Residential Demolition Authorization Permit, Sequential Lot Line Adjustment, Special Use Permit, Coastal Permit, Design Permit, and Heritage Tree Removal Permit to reconfigure five lots into two, demolish two existing school buildings (approximately 28,417 square feet), remove six heritage trees, and construct a 76-unit (including 13 full dwelling units) senior housing facility as approved by the Planning Commission, but with the deletion of condition of approval 60.

Adjournment
City Council Special Meeting

AGENDA REPORT
DATE: 11/16/2022
AGENDA OF: 11/29/2022
DEPARTMENT: City Council
SUBJECT: City Council and Community Support of UC Academic Worker Strike and “Fair UC Now” Bargaining Requests (CN)
RECOMMENDATION: Motion to direct the Mayor to write a letter on behalf of the City Council and Santa Cruz community to the University of California (UC) Regents, the ‘Fair UC Now’ and UC Regents bargaining teams, and UC President Michael V. Drake to acknowledge how difficult it is for UC graduate students and UC workers to afford to live in communities across the state of California where the cost of rent far outstrips their salaries; express the Santa Cruz City Council and community support of the current UAW 5810, UAW 2865, and SRUUAW Postdoc, Academic Researcher, Graduate Student Researcher, Trainees, Fellows, Graduate Student Instructors, Readers and Tutors strike and the students’ bargaining proposal as presented in the campaign “Fair UC Now”; and urge the UC Regents to find an immediate remedy and resolution.

BACKGROUND: California is the most expensive state for rental housing in the entire nation.

In particular, Santa Cruz ranks the second most expensive county for rental housing in the entire country. The increase in the cost of living in California has far outpaced the increase in salaries of workers and graduate students that work for the University of California (UC) across the state.

This has forced many workers and students to become rent burdened ("Bargaining for a Fair UC Summary"), and/or put them in situations where they have to take on multiple jobs. For workers, this reduces morale, which can have significant negative impacts on productivity and retention.

For graduate students, this is particularly burdensome given their additional commitments to their studies and research on top of their workloads. For workers and graduate students with children or who are caring for family members, the strain is even greater.

Due to an inability to reach a fair contract through collective bargaining, on November 3, 2022, 97% of 36,558 UC Academic Workers voted to go on strike. On November 14, 2022 UAW 5810, UAW 2865, and SRU-UAW representing postdoc, academic researcher, graduate student researchers, trainees, fellows, graduate student instructors, readers and tutors went on strike under the banner “Fair UC Now” (www.fairucnow.org).

This is the largest academic strike in US history with 48,000 workers going on strike across 10 UC campuses. The demands of the workers center around fair compensation, climate friendly sustainable transportation, support for working parents, international scholar rights, job security, disability justice, and anti-bullying protections. "Bargaining for a Fair UC Summary" provides a

1.1 summary of the bargaining proposal and "CORE UC Worker Demands" provides the core demands as listed on the “Fair UC Now” website: www.fairucnow.org.

DISCUSSION: As a community that has a UC campus, we want to see the best outcome for students, staff, and faculty across all UC campuses, and for those who live here in Santa Cruz and work at UCSC. We want students and workers to feel supported by the institutions they serve. Across the UC campuses over 70% of UC academic workers are rent burdened and with Santa Cruz being the second most expensive housing rental community in the nation, we know that this is particularly bad for University of California Santa Cruz (UCSC) graduate students and workers.

In 2020, the Santa Cruz City Council supported the UCSC graduate student wildcat strike by writing a letter in support of their demands for a cost-of-living adjustment (COLA). Striking graduate students and workers have reached out and expressed that they would like local elected officials to do what they can in their elected capacity to support their efforts during the current strike. The City Council is being asked to consider directing the Mayor to write a letter on behalf of the City Council and Santa Cruz community to the University of California (UC) Regents, the ‘Fair UC Now’ and UC Regents bargaining teams, and UC President Michael V.

Drake to acknowledge how difficult it is for UC graduate students and UC workers to afford to live in communities across the State of California where the cost of rent far outstrips their salaries; express City of Santa Cruz Council support of the current UAW 5810, UAW 2865, and SRU-UAW Postdoc, Academic Researcher, Graduate Student Researcher, Trainees, Fellows, Graduate Student Instructors, Readers and Tutors strike, and the students’ bargaining proposal as presented in the campaign “Fair UC Now”; and urge the UC to find an immediate remedy and resolution.

The Santa Cruz City Council supports building an environment, on and off campus, where everyone - undergraduates, graduate students, university staff, and community members - can thrive. This issue affects the very heart of the economic and social health of this community. A COLA increase and a speedy resolution to this matter is what is necessary. If UCSC or the UC Regents would like to call upon the auspices of the Mayor and City Council in resolving this matter, Councilmembers stand ready to assist in any mediation effort.

FISCAL IMPACT: None.

Submitted By:

Justin Cummings
Councilmember
Submitted By:

Sonja Brunner
Mayor
Submitted By:

Sandy Brown
Councilmember
ATTACHMENTS:

1. BARGAINING FOR A FAIR UC SUMMARY.PDF

2. CORE UC WORKER DEMANDS.DOCX

1.2 Compensation
Free public transit passes and cash
incentives for workers who use
sustainable transit options

OUR PROPOSALS UC'S PROPOSALS
48,000 Academic Student Employees, Postdocs, Academic Researchers, and Student Researchers across UC are uniting in our struggle for an equitable university where everyone can thrive. Here's a summary of major bargaining demands put forward by UAW2865, UAW5810, and SRU-UAW relative to UC's proposals.

BARGAINING FOR A FAIR UC
Transit &
Climate Justice
Childcare
Job Security
Protections Against
Abusive Conduct
Equity for
International
Scholars
$2000/month childcare
reimbursements, dependent healthcare
Guaranteed year-long, multi-year
appointments for Grad Workers.

Longer appointments for Postdocs & ARs
Remission of Non-Residential
Supplemental Tuition and
reimbursement of all visa fees
$54,000/year minimum salary for all
Grad Workers
$70,000/year minimum salary for
Postdocs
14% initial salary increase for
Academic Researchers
Annual cost of living adjustments and
experience-based increases
Short appointments, limited job stability
For Student Researchers: 6% raise, 3%
annual raises thereafter
For Academic Student Employees: 7%
raise, 3% annual raises thereafter
For Postdocs: $59,362 minimum salary,
3% annual increases, higher benefit costs
For Academic Researchers: 4% raise, 3%
annual raises thereafter
No guaranteed subsidies for public
transportation passes or cash incentives
for non-drivers.
$450/month in childcare reimbursements
for Grad workers; $208/month for
Postdocs; none for ARs
Maintain status quo of extra fees and
tuition for international workers
Victory! The Respectful Work Environment article, which makes abusive conduct & bullying a violation of our contract, has reached tentative agreement. This groundbreaking victory will give us the ability to seek real recourse through our grievance procedure, with timelines and interim measures to protect survivors.

Disability Justice
Interim Accommodations to address delays
and improvements to digital accessibility
and accommodations processes
Minimal changes beyond the bare
minimum required by law

1.3 48,000
UC academic workers are
bargaining for new
contracts with UC in 2022
OUR UNITY IS POWERFUL.

OUR RENT BURDEN IS UNACCEPTABLE.
19,000
TAs, Readers, and Tutors
in UAW 2865
12,000
Postdocs and
Academic Researchers
in UAW 5810
17,000
Student Researchers in

SRU-UAW
Over 70% of
UC Academic
Workers are
rent burdened
Our work makes up the
majority of teaching and
research at UC, which brings
in record-setting grant and
state funding.

Our compensation should
match our contributions and
keep up with the cost of
living.

Instead of addressing our rent burden,
UC bought President Drake a
$6.5 million mansion.

Get connected
with your
union.
fairUCnow.org

1.4 Attachment 2. Core ‘Fair UC Now’ UC Academic Workers Union demands as present on the ‘Fair UC Now’ website (www.fairucnow.org).

Fair Compensation & Cost of Living
Adjustments
UC’s failure to support a diverse workforce undermines the quality of research and education. Compensation that doesn’t match the cost of living and inequitable working conditions are pushing scholars out of academia. We do the majority of teaching and research at UC, yet UC is refusing to offer us a fair share of the record-setting grant and state funding that our labor brings in. To correct all of this, 48,000 UAW-represented Academic Workers are demanding:
 $54,000/year minimum salary for all Grad Workers
 $70,000/year minimum salary for Postdocs
 14% salary increase for Academic Researchers
 Annual cost of living adjustments and experience-based increases Climate & Transit
To combat climate change and reduce emissions, 48,000 UAW-represented Academic Workers are demanding:
 Free public transit passes for all workers who want them  Cash incentives to commute via sustainable means
 Subsidies for the purchase and maintenance of bikes and e-bikes  Improved campus cycling infrastructure
Support for Parents & Families
To support and retain parent-workers and promote gender equity at UC, 48,000 UAWrepresented Academic Workers are demanding:
 $2000/month childcare reimbursements
 Full tuition subsidies at UC-affiliated childcare programs  Dependent healthcare
 Expanded paid parental and family leave

1.5 International Scholar Rights
To support and retain international scholars and advance equity at UC, 48,000 UAW represented Academic Workers are demanding:
 Full remission of Non-Resident Supplemental Tuition (NRST)  Reimbursement of all visa fees
 Longer appointments to enable longer visas for international scholars Job Security
To encourage bold research and deter bullying and abuse, Academic Workers are proposing:
 Longer guaranteed appointment lengths (all units)
 Appointment security (all units)
 Establishment of a Bridge Funding program (Academic Researchers) Disability Justice
To support and retain disabled workers at UC, 48,000 UAW-represented Academic Workers are demanding:
 Fully accessible technology and software
 Online access options for lab meetings, research seminars, and the like  A faster, more streamlined process to address access needs Victory! Historic protections against
bullying will be enshrined into all four UAW

1.6 contracts, establishing the right to real
recourse for 48,000 workers.

The Respectful Work Environment article, which makes abusive conduct & bullying a violation of our contract, has reached tentative agreement. This groundbreaking victory will give us the ability to seek real recourse through our grievance procedure. Specifically, the article guarantees:
 Clear timelines to investigate and resolve abusive conduct under the grievance process including appeal to third-party arbitration if necessary,  A strong definition of abusive conduct with clear examples of abusive behavior that will allow us to enforce protections,
 Worker-centered protections and interim measures – for example, a worker can work from a different lab or work remotely while their issue is being resolved,  Secure protections that prevent UC from changing definitions or resolution procedures unilaterally.

This historic win is a direct result of mass collective action by all UC Academic Workers.

1.7 1
Bonnie Bush
From: Garrett <[email protected]>
Sent: Tuesday, November 22, 2022 10:10 PM
To: City Council
Subject: 11.29.22 Consent Agenda Item #1 Letter of Union Support?

11.29.22 Consent Agenda Item #1 Letter of Union Support? Dear Council,
I have issues with government unions, particularly with teacher unions. In recent decades, a lot of their union dues went to political campaigns , hundreds of millions of dollars. Taxpayers and students pay those teachers salaries, and neither the public nor the teachers have much say in how that money is used politically.

For instance, it was teacher unions that kept children out of school during Covid when THE SCIENCE says that was an
unwarranted mistake and harmed students producing an
unjustified lack of development. Mostly they were cowards who didn't want to work. They should stick to traditional union matters (which I suppose this is).

Where it certainly may be true that inflation among other reasons has made cost of living proportionally higher for every one, you may want to at least acknowledge some reality. 1) In America, the principal of capitalism means people provide what others want, need, and are willing to pay for. This only works well in a free market with competition, and monopiles can very much take advantage of that.

The government is the ultimate monopoly, and particular attention must be paid to how much government employees are paid
relative to the same job in the private sector (of which I see no analysis), only "I want, I need more money". While I can appreciate government employees have the right to ask for more money, it is the fiduciary responsibility of those in charge to keep salaries in line with the private sector and not just SOAK THE TAXPAYER (or students). Everyone struggles with inflation.

1.8 2
2) Perhaps a better letter might be to those who cause inflation.

The Federal government with unimaginable excess deficit spending and national debt leading to money printing which is the primary cause of inflation. Also those who would lend students any amount of money to go to college whether they have the academic "chops" or not. More inflation caused by debt, and more ability to raise tuition.

I'm not saying that the University system doesn't have a pay system that is beyond examination for administrative salaries, all other salaries, excess positions, positions filled by those who aren't worth that much, etc. It sure is.

I don't detect one iota of concern for any imbalances such as those.

For instance,
The Oregon Association of Scholars James Lindsay, Bruce Gilley, and Peter Boghossian defined Diversity, Equity, and Inclusion at universities (DEI) as diversity is “an identity-based approach to society; includes only those who agree with Social Justice, which is a violation of individual identity; enforced intellectual conformity, political quotas; an attack on merit and a form of soft bigotry.” Equity, they write, now means the new inequality that we have seen, and “equality of outcomes plus reparations, which is a violation of equality before the law, a dismantling of the foundations of a free society [and] state management of society by redistributing resources, opportunity, and access.” Inclusion, the three write, now means “restricted speech and justification for purges,” which is, “an attack on freedoms of association and speech [and] an enforced separation of people by race (‘neo-segregation’).”
This reads like a possible area of cost savings that could be passed onto other positions worthy of a mention.

The Heritage Foundation did a 2021 study of 65 of the largest universities by The Heritage Foundation’s Jay Greene found that the average American university has 45 DEI personnel who act as political commissars enforcing the cultural Marxist ideology of DEI. (The University of Michigan alone has 163.) That means that universities have 40 percent more DEI staff than history professors!

1.9 3
Jay P. Greene and James D. Paul, “Diversity University, DEI Bloat at the Academy,” Heritage Foundation Backgrounder No. 3642, July 27, 2021, https://www.heritage.org/sites/default/files/2021-07/BG3641_0.pdf. That total number of DEI staff excludes Title IX and legal compliance staff and ethnic and gender study professors and related staff.

Greene’s study examined campus climate survey results to see if the number of DEI staff made campuses more welcoming or inclusive, and unsurprisingly he found that the opposite was the case.

You might consider urging the University to examine and cut a lot of these Cultural Marxist indoctrination specialists from University staff. I could seriously say the same for the Cities staff.

Soak the taxpayer is no joke and administrative expense is a large part of that, particular when some of that staff seek to undermine essential American principals.

Really, a consent agenda item backing unions?? again??
Garrett Philipp - Westside

1.10 City Council Special Meeting

AGENDA REPORT
DATE: 11/17/2022
AGENDA OF: 11/29/2022
DEPARTMENT: Fire
SUBJECT: Purchase of Type 1 Fire Engine (FD)
RECOMMENDATION: Motion to:
1) Adopt a resolution amending the FY 2023 budget to transfer $850,000 from the City of Santa Cruz Capital Investment Program (CIP) to FY 2023 Fire Department Capital CIP budget number c212315; and
2) Approve the purchase of a type 1 Fire Engine, using Project c212315, in the amount of $850,000.00 from Golden State Fire Apparatus.

BACKGROUND: Santa Cruz Fire Department’s current type 1 Fire Engine has exceeded its service life and has been recommended for replacement due to its age that exceeds National Fire Protection Agency (NFPA) standard for type 1 fire engine replacement. The current type 1 fire engine vehicle has had several major breakdowns while responding to calls in the City of Santa Cruz.

DISCUSSION: A new type 1 Fire Engine will provide a reliable vehicle when responding to fires and all other hazard emergencies within the City of Santa Cruz, to adjoining agencies, and for statewide mutual aid incidents. Additionally, the fire apparatus industry has significantly improved a number of safety features and this new engine will benefit from those enhancements.

As part of the City’s purchasing processes, a “single source” may be authorized without a formal process when a good or service needs to be procured timely. After reviewing a single source justification from the Fire Chief, Purchasing has determined that the proposed purchase meets the definition of a single source and recommends Council approve the purchase.

FISCAL IMPACT: The purchase of this type 1 Fire Engine was identified as a Priority Level One project in the FY 2023 funded Capital Investment Program adopted by Council in June 2022. The purchase price is $850,000. Funds for the purchase of this engine will be transferred from two current CIP projects - $750,000 from c212302 Fire Station 2 Exercise & Storage Facility (rear expansion) and $100,000 from c212303 Generator for Fire Station #3 to c212315 Fire Engine type 1 Pierce. No new appropriations are needed.

2.1 Prepared By:

Paul Horvat
Principal Management
Analyst
Submitted By:

Rob Oatey
Fire Chief
Approved By:

Matt Huffaker
City Manager
ATTACHMENTS:

1. BUDGET ADJUSTMENT.PDF

2. PURCHASING MEMO - SINGLE SOURCE JUSITIFICATION - GOLDEN STATE FIRE APPARTUS.PDF

3. GOLDEN STATE FIRE APPARATUS PRICE QUOTATION.PDF

2.2 City of Santa Cruz

BUDGET ADJUSTMENT REQUEST
$GPLQLVWUDWLYH$SSURYDO
)LVFDO<HDU

ACCOUNT 352-(&71$0(
LIDSSOLFDEOH
255(9(18($&&28177,7/(
ACCOUNT 352-(&71$0(
LIDSSOLFDEOH
25EXPENDITURE ACCOUNT TITLE
NET: $

REQUESTED BY DEPARTMENT HEAD

APPROVAL

BUDGET/ACCOUNTING
5(9,(:('

FINANCE DIRECTOR

APPROVAL

CITYMANAGER

APPROVAL
5HVR

352-(&7
352-(&7
$02817
$02817
&RXQFLO$SSURYDO

TOTAL EXPENDITURE

TOTALREVENUE
'DWH

1VSQPTF
3FWJTFE/PWFNCFS
 Clear Form
2023
11/17/2022
Transfer funds to purchase a new Type 1 Fire Engine
0 311-21-31-2202-57490 c212302-100-2020 Fire Station 2 Exercise and Storage Fac. -750,000 311-21-31-2202-57490 c212303-100-2020 Fire Station # 3 Generator -100,000 311-21-31-2202-57402 c212315-100-2020 Fire Engine 1500 GPM Pierce Pumper 850,000 0 0
Paul
Horvat
Digitally signed by Paul Horvat
DN: cn=Paul Horvat, o=City of
Santa Cruz, ou=Fire Department,
[email protected]
om, c=US
Date: 2022.11.17 11:33:57 -08'00'
Paul
Horvat
Digitally signed by Paul Horvat
DN: cn=Paul Horvat, o=City of Santa
Cruz, ou=Fire Department,
[email protected]
, c=US
Date: 2022.11.17 11:34:16 -08'00'
Tracy
Cole
Digitally signed by Tracy Cole
DN: cn=Tracy Cole, o=City of
Santa Cruz, ou=Finance,
[email protected]
om, c=US
Date: 2022.11.17 11:03:22
-08'00'
Elizabet
h Cabell
Digitally signed by Elizabeth Cabell
DN: cn=Elizabeth Cabell, o=City of Santa Cruz,
ou=Finance Department,
[email protected], c=US
Date: 2022.11.17 11:56:12 -08'00'

2.3 MEMORANDUM
DATE: November 17, 2022
TO: Elizabeth Cabell, Finance Director
FROM: Elizabeth Millwee, Purchasing Manager
SUBJECT: Single Source Justification for Pierce 1500 GMP Pumper Engine Purchase Recent constraints on supply chain have caused an order back log for more specialized products like fire engines. The City has an urgent need to purchase a fire engine and is able to procure a replacement model for an existing engine in the Fire Department’s fleet. The Fire Department is requesting to purchase a Pierce 1500 GMP Pumper Engine Purchase and has solicited a quote from Golden State Fire Apparatus.

As part of the city’s purchasing processes, a “Single Source” may be authorized when a good or service needs to be procured timely without a formal process.  After discussions with the Fire Chief, the proposed good meets the definition of a Single Source scenario.

Municipal Code Section 3.08.160 additionally authorized the Purchasing Manager to make or authorize others to make emergency procurement of supplies and services items when there exists a threat to public health, welfare, or safety; provided that such emergency procurement shall be made with such competition as is practicable under the circumstances.

The City Council is scheduled to consider this purchase at its meeting on November 29, 2022.  If this item is approved by the Council, the City will need to move expeditiously with and order to the vendor to reserve this specialized emergency response fleet vehicle.

The pricing provided in Attachment A ‐ Golden State Fire Apparatus Price Quotation has been evaluated and determined to be fair and reasonable through a price analysis completed by the Fire Department staff. This memorandum serves as authorization to proceed with a Single Source contract with Panther Protective Services under the following conditions:
 The contract is approved by the Council on November 29, 2022; and,  Golden State Fire Apparatus provides the required documentation to do business with the City as required by the Finance Department; and,
Please feel free to contact me should you have any questions.

CC: Robert Oatey, Fire Chief
ATTACHMENTS:

Attachment A ‐ Golden State Fire Apparatus Price Quotation

2.4 PRODUCT

PROPOSAL
Exhibit “A”
Bid #933

2.5 PROPOSAL PREPARED FOR
Santa Cruz Fire Department
Pierce Manufacturing, Inc.

STOCK Enforcer 1500 GPM Pumper
(Job 39133)
November 1, 2022

SALES CONSULTANT
Rich Myers
Golden State Fire Apparatus, Inc.
7400 Reese Road
Sacramento, CA 95828
831.251.8931 Cell
[email protected]

PARTS, SERVICE & SUPPORT
Golden State Emergency Vehicle Service, Inc.
7400 Reese Road
Sacramento, CA 95828
916.330.1638 Office
[email protected]

2.6

Page 2 of 3 ends

www.goldenstatefire.com
7400 Reese Road
Sacramento, CA 95828
Office 916.330.1638
Fax 916.330.1649
PROPOSAL PREPARED FOR:

Santa Cruz Fire Department
230 Walnut Avenue
Santa Cruz, CA 95060
We hereby propose and agree to furnish, after your acceptance of this proposal and the proper execution by the SANTA CRUZ FIRE DEPARTMENT, hereinafter called “Customer” and an officer of Golden State Fire Apparatus, Inc., hereinafter called “GSFA”, the following fire apparatus and equipment, hereinafter called “Product”:

PROPOSAL SUMMARY
This proposal includes the following items in accordance with the specifications hereto attached:
 Fire apparatus and equipment described herein
 Delivery to GSFA service center in Sacramento
 Pre-delivery inspection/services by GSFA
 Final delivery from service center to Customer

PRODUCT COMPLETION
Product shall be built in accordance with the specifications hereto attached, delays due to acts of God, strikes, war, or intentional conflict, failures to obtain chassis, materials, unusual weather conditions or other causes beyond GSFA’s control not preventing, within approximately 150 to 180 CALENDAR DAYS after receipt of this order and the acceptance thereof at our Sacramento, California office. Within thirty (30) calendar days after receipt of this order and acceptance thereof, GSFA shall submit to Customer a production schedule including tentative pre-construction conference, final inspection and final delivery dates.

DELIVERY LOCATION
Product shall be shipped in accordance with the specifications hereto attached and be delivered to you at SANTA CRUZ, CALIFORNIA. Proof of insurance must be demonstrated by the Customer to GSFA prior to transferring of the Product(s).

Submitted Date: November 1, 2022
Proposal Number: 41101-22B
Expiration
Date: December 1, 2022
Sales Consultant: Rich Myers
# Description Unit Price
A One (1) Pierce Manufacturing, Inc. STOCK Enforcer 1500 GPM Pumper (Job 39133) 728,897.01 B 9.25% State Sales Tax 67,422.97
C California Tire Fee 10.50
D GRAND TOTAL 796,330.48

2.7 7400 Reese Road, Sacramento, CA 95828 | Office 916.330.1638 | Fax 916.330.1649

Page 3 of 3 ends

ACCEPTING THIS PROPOSAL
In the event Customer wishes to purchase the Product described in this Proposal and the attached specifications, then, prior to the expiration date listed on page 2 of this Proposal, Customer shall sign and return this Proposal. Thereafter, GSFA and Customer will endeavor to enter into a purchase agreement incorporating this Proposal and including additional terms (a “Purchase Agreement”). If Customer returns a signed copy of this Proposal alone, GSFA will send Customer its form of Purchase Agreement for Customer’s review and signature. If Customer desires to use its standard form of purchase order as the Purchase Agreement, then Customer should return a signed copy of this Proposal along with a copy of such purchase order. All purchase orders shall be made out to GSFA. GSFA will review such purchase order and contact the Customer regarding any required revisions. Only upon a full execution of a Purchase Agreement shall GSFA and Customer be obligated to purchase and sell the Product set forth in this Proposal.

TERMS AND CONDITIONS
The following Terms and Conditions are hereby made part of this Proposal:

1. Payment Terms (Payment at Time of Delivery) – Customer shall pay the Grand Total at time of delivery or pick up of the Product to GSFA. It is the responsibility of the Customer to have full payment ready when the Product is complete and ready to deliver or pick up. If payment is late or delivery is delayed pending payment, a daily finance charge of $150.00 and a daily storage fee of $50.00 may apply until such payment is received.

Due to insurance liability, the Product(s) will not be left at the Customer’s location without full acceptance and payment or prior written agreement between the Customer and GSFA.

2. Multiple Unit Purchase – If the Purchase Price includes pricing for multiple units, the price stated on this Proposal shall only be valid if the quantity of Products being proposed are purchased at the same time, pursuant to the same Purchase Agreement.

3. Stock / Demo Units – If applicable, any stock/demo units, including those identified by this Proposal, are available for sale on an as-is, first-come and first served-basis. Regardless of this Proposal, the first Customer to enter into a Purchase Agreement identifying any such stock/demo unites shall obtain said units.

4. Order Changes – The Customer may request that GSFA
incorporate a change to the Product or the Specifications for the Product by delivering a written change order to GSFA, which shall include a description of the proposed change sufficient to permit GSFA to evaluate the feasibility of such change (a “Change Order”). GSFA will provide Customer a written response (a “Response”) stating (i) whether GSFA will accommodate such Change Order (which GSFA may decide in its sole and absolute discretion) and (ii) the terms of the modification to the order, including any increase or decrease in the Purchase Price resulting from such Change Order, and any effect on production
scheduling or Delivery resulting from such Change Order.

Customer shall have seven (7) days after receipt of the Response to notify GSFA as to whether Customer desires to make the changes GSFA has approved in the Response. In the event Customer counter-signs GSFA’s Response, Customer shall pay the increase (or be refunded the decrease) in the Purchase Price prior to final delivery to Customer location.

5. Force Majeure – GSFA shall not be responsible nor deemed to be in default on account of delays in performance due to causes which are beyond GSFA’s and manufacturer’s control and which make GSFA’s performance impracticable, including but not limited to wars, insurrections, strikes, riots, fires, storms, floods, other acts of nature, explosions, earthquakes, accidents, any act of government, delays in transportation, inability to obtain necessary labor supplies or manufacturing facilities, allocation regulations or orders affecting materials, equipment, facilities or completed products, failure to obtain any required license or certificates, acts of God or the public enemy or terrorism, failure of transportation, epidemics, quarantine restrictions, failure of vendors (due to causes similar to those within the scope of this clause) to perform their contracts or labor troubles causing cessation, slowdown, or interruption of work.

6. Cancellation/Termination – In the event Customer and GSFA enter into a Purchase Agreement and Customer thereafter cancels or terminates the Purchase Agreement, GSFA will charge a cancellation fee as follows: (a) 10% of the Purchase Price after order is accepted and entered by GSFA; (b) 20% of the Purchase Price after completion of the pre-construction phase of the order process; and (c) 50% of the Purchase Price after the requisition of any materials or commencement of any manufacturing or assembly of the Product by either GSFA or the manufacturer of the Product. The tier of cancellation fee applicable to any cancellation shall be in the sole and absolute discretion of GSFA.

7. State Sales Tax – Customer shall be responsible for the cost of state sales tax associated with, or attributable to the Product.

The taxes owed by Customer for the Product is subject to adjustment for the applicable state sales tax rate in effect when the Product is delivered to the Customer. Therefore, the sales tax will be increased or decreased at the time of delivery if a change in the sales tax rate has occurred, in which case Customer shall pay GSFA (or be refunded by GSFA) the applicable change in sales tax.

8. Proposal Expiration – After the Expiration Date shown on page one of this Proposal, Customer shall require GSFA’s written consent to accept this Proposal.

9. Governing Law – This Proposal is to be governed by and under the laws of the state of California.

Thank you for providing Golden State Fire Apparatus, Inc. with the opportunity to provide this proposal. If you have any questions regarding the options presented or need additional options, please contact me.

Sincerely, I, _______________________________________________________________authorized representative of SANTA CRUZ FIRE DEPARTMENT agrees to purchase the proposed Product(s) and agree to the terms and conditions of this proposal and the specifications hereto attached.

Rich Myers SIGNATURE: __________________________________________________________________________ Golden State Fire Apparatus, Inc.

TITLE: _________________________________________________ DATE: ____________________

2.8 PRODUCT

SPECIFICATIONS
Exhibit “B”
Bid #933

2.9 Proposal Details Report
OptionCode Type Option ProposalText
0010012 No Boiler Plates requested

0661794 Single Source Compliance

SINGLE SOURCE MANUFACTURER
Pierce Manufacturing, Inc. provides an integrated approach to the design and manufacture of our products that delivers superior apparatus and a dedicated support team. From our facilities, the chassis, cab weldment, cab, pumphouse (including the sheet metal enclosure, valve controls, piping and operators panel) and body will be entirely designed, tested, and hand assembled to the customer's exact specifications. The electrical system either hardwired or multiplexed, will be both designed and integrated by Pierce Manufacturing. The warranties relative to these major components (excluding component warranties such as engine, transmission, axles, pump, etc.) will be provided by Pierce as a single source manufacturer. Pierce's single source solution adds value by providing a fully engineered product that offers durability, reliability, maintainability, performance, and a high level of quality.
0584456 Manufacture Location, Appleton,
Wisconsin
Your apparatus will be manufactured in Appleton, Wisconsin. 0584452 RFP Location: Appleton, Wisconsin

0588609 Vehicle Destination, US

0670275 Unit to be Similar in some Aspects,
Excluding Pump Panel

SPECIAL INSTRUCTIONS
The apparatus being proposed will be designed and built to match the For Engineering Purposes Only. Similar to job 38565.  However, some variation may be necessary due to changes in our manufacturing processes or our product offering.  Revisions in NFPA guidelines and/or other regulations may also affect our ability to match the previous unit. 0610784 Comply NFPA 1901 Changes
Effective Jan 1, 2016, With
Exceptions
NFPA 2016 STANDARDS
This unit will comply with the NFPA standards effective January 1, 2016, except for fire department directed exceptions. These exceptions will be set forth in the Statement of Exceptions.

Certification of slip resistance of all stepping, standing and walking surfaces will be supplied with delivery of the apparatus.

All horizontal surfaces designated as a standing or walking surface that are greater than 48.00" above the ground must be defined by a 1.00" wide line along its outside perimeter. Perimeter markings and designated access paths to destination points will be identified on the customer approval print and are shown as approximate. Actual location(s) will be determined based on materials used and actual conditions at final build. Access paths may pass through hose storage areas and opening or removal of covers or restraints may be required. Access paths may require the operation of devices and equipment such as the aerial device or ladder rack.

A plate that is highly visible to the driver while seated will be provided. This plate will show the overall height, length, and gross vehicle weight rating.

The manufacturer will have programs in place for training, proficiency testing and performance for any staff involved with certifications.

An official of the company will designate, in writing, who is qualified to witness and certify test results.
0533347 Pumper/Pumper with Aerial Device
Fire Apparatus
0588611 Vehicle Certification, Pumper

11/1/2022
Customer: CITY OF SANTA CRUZ FIRE
DEPT
Bid Number: 933
Representative Myers, Rich Job Number:

Requirements Manager: Organization: Golden State Fire Apparatus, Inc Description: Santa Cruz Stock 1500 Pumper
Chassis: Enforcer Chassis
Body: Pumper, Medium, Aluminum, 2nd Gen
Bid #: 933 1

2.10 0661778 Agency, Apparatus Certification,
Pumper/Tanker, U.L.

NFPA COMPLIANCY
Apparatus proposed by the bidder will meet the applicable requirements of the National Fire Protection Association (NFPA) as stated in current edition at time of contract execution. Fire department's specifications that differ from NFPA specifications will be indicated in the proposal as "non-NFPA".

PUMP TEST
Underwriters Laboratory (UL) will test, approved, and certify the pump. The test results and the pump manufacturer's certification of hydrostatic test; the engine manufacturer's certified brake horsepower curve; and the pump manufacturer's record of pump construction details will be forwarded to the Fire Department.

GENERATOR TEST
If the unit has a generator, Underwriters Laboratory (UL) will test, approved, and certify the generator. The test results will be provided to the Fire Department at the time of delivery.

BREATHING AIR TEST
If the unit has breathing air, Pierce Manufacturing will draw an air sample from the air system and have the sample certified that the air quality meets the requirements of NFPA 1989, Standard on Breathing Air Quality for Fire and Emergency Services Respiratory Protection. 0891947 Certification, Vehicle Inspection
Program, NFPA 1901

VEHICLE INSPECTION PROGRAM CERTIFICATION
To assure the vehicle is built to current NFPA 1901 standards, the apparatus, in its entirety, will be third-party, independent, audit-certified through Underwriters Laboratory (UL) that it is built and complies to all applicable standards in the current edition. The certification includes: all design, production, operational, and performance testing of not only the apparatus, but those components that are installed on the apparatus.

A placard will be affixed in the driver's side area stating the third party agency, the date, the standard and the certificate number of the whole vehicle audit. 0537375 Unit of Measure, US Gallons

0030006 Bid Bond Not Requested

BID BOND NOT REQUESTED
A bid bond will not be included. If requested, the following will apply:

All bidders will provide a bid bond as security for the bid in the form of a 5% bid bond to accompany their bid. This bid bond will be issued by a Surety Company who is listed on the U.S.

Treasury Departments list of acceptable sureties as published in Department Circular 570. The bid bond will be issued by an authorized representative of the Surety Company and will be accompanied by a certified power of attorney dated on or before the date of bid. The bid bond will include language, which assures that the bidder/principal will give a bond or bonds as may be specified in the bidding or contract documents, with good and sufficient surety for the faithful performance of the contract, including the Basic One (1) Year Limited Warranty, and for the prompt payment of labor and material furnished in the prosecution of the contract.

Notwithstanding any document or assertion to the contrary, any surety bond related to the sale of a vehicle will apply only to the Basic One (1) Year Limited Warranty for such vehicle. Any surety bond related to the sale of a vehicle will not apply to any other warranties that are included within this bid (OEM or otherwise) or to the warranties (if any) of any third party of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. In the event of any contradiction or inconsistency between this provision and any other document or assertion, this provision will prevail.
0540326 Performance Bond, Not Requested

PERFORMANCE BOND NOT REQUESTED
A performance bond will not be included. If requested at a later date, one will be provided to you for an additional cost and the following will apply:

The successful bidder will furnish a Performance and Payment bond (Bond) equal to 100 percent of the total contract amount within 30 days of the notice of award. Such Bond will be in a form acceptable to the Owner and issued by a surety company included within the Department of Treasury's Listing of Approved Sureties (Department Circular 570) with a minimum A.M. Best Financial Strength Rating of A and Size Category of XV. In the event of a bond issued by a surety of a lesser Size Category, a minimum Financial Strength rating of A+ is required.

Bidder and Bidder's surety agree that the Bond issued hereunder, whether expressly stated or not, also includes the surety's guarantee of the vehicle manufacturer's Bumper to Bumper warranty period included within this proposal. Owner agrees that the penal amount of this bond will be simultaneously amended to 25 percent of the total contract amount upon satisfactory acceptance and delivery of the vehicle(s) included herein. Notwithstanding anything contained within this contract to the contrary, the surety's liability for any warranties of any type will not exceed three (3) years from the date of such satisfactory acceptance and delivery, or the actual Bumper to Bumper warranty period, whichever is shorter. 0000007 Approval Drawing APPROVAL DRAWING
A drawing of the proposed apparatus will be prepared and provided to the purchaser for approval before construction begins. The Pierce sales representative will also be provided with a copy of the same drawing. The finalized and approved drawing will become part of the contract documents. This drawing will indicate the chassis make and model, location of the lights, siren, horns, compartments, major components, etc.

A "revised" approval drawing of the apparatus will be prepared and submitted by Pierce to the purchaser showing any changes made to the approval drawing. 0002928 Electrical Diagrams

ELECTRICAL WIRING DIAGRAMS
Two (2) electrical wiring diagrams, prepared for the model of chassis and body, will be provided.

Bid #: 933 2

2.11 0649754 Enforcer Chassis

ENFORCER CHASSIS
The Pierce Enforcer™ is the custom chassis developed exclusively for the fire service. Chassis provided will be a new, tilt-type custom fire apparatus. The chassis will be manufactured in the apparatus body builder's facility eliminating any split responsibility. The chassis will be designed and manufactured for heavy-duty service, with adequate strength, capacity for the intended load to be sustained, and the type of service required. The chassis will be the manufacturer's first line tilt cab.
0000110 Wheelbase WHEELBASE
The wheelbase of the vehicle will be 191.50".
0000070 GVW Rating GVW RATING
The gross vehicle weight rating will be 42,000#.
0649713 Frame Rails, 10.25" x 3.50" x .375",
Saber FR/Enf
FRAME
The chassis frame will be built with two (2) steel channels bolted to five (5) cross members or more, depending on other options of the apparatus. The side rails will be heat-treated steel measuring 10.25" x 3.50" x 0.375".

Each rail will have a section modulus of 16.00 cubic inches, yield strength of 120,000 psi, and a resisting bending moment (rbm) of 1,921,069 inch-pounds. 0648354 Frame Liner, Internal "C", 9.38" x

3.13" x .25", Saber FR/Enf, 26" Qval

FRAME REINFORCEMENT
A full-length mainframe "C" liner will be provided.

The liner will be an internal "C" design, heat-treated steel measuring 9.38" x 3.13" x 0.25". Each reinforcement member will have a section modulus of 3.90 cubic inches, yield strength of 120,000 psi and resisting bending moment (rbm) of 938,762 in-lb. 0633906 Axle, Front, Oshkosh TAK-4, Non
Drive, 18,000 lb, Enforcer

FRONT NON DRIVE AXLE
The Oshkosh TAK-4® front axle will be of the independent suspension design with a ground rating of 18,000 lb.

Upper and lower control arms will be used on each side of the axle. Upper control arm castings will be made of 100,000-psi yield strength 8630 steel and the lower control arm casting will be made of 55,000-psi yield ductile iron.

The center cross members and side plates will be constructed out of 80,000-psi yield strength steel.

Each control arm will be mounted to the center section using elastomer bushings. These rubber bushings will rotate on low friction plain bearings and be lubricated for life. Each bushing will also have a flange end to absorb longitudinal impact loads, reducing noise and vibrations.

There will be nine (9) grease fittings supplied, one (1) on each control arm pivot and one (1) on the steering gear extension.

The upper control arm will be shorter than the lower arm so that wheel end geometry provides positive camber when deflected below rated load and negative camber above rated load.

Camber at load will be zero degrees for optimum tire life.

The ball joint bearing will be of low friction design and be maintenance free.

Toe links that are adjustable for alignment of the wheel to the center of the chassis will be provided.

The wheel ends must have little to no bump steer when the chassis encounters a hole or obstacle.

The steering linkage will provide proper steering angles for the inside and outside wheel, based on the vehicle wheelbase.

The axle will have a turning angle of up to 45 degrees. 0633905 Suspension, Front TAK-4, 18,000 lb,
Enforcer

FRONT SUSPENSION
Front Oshkosh TAK-4™ independent suspension will be provided with a minimum ground rating of 18,000 lb.

The independent suspension system will be designed to provide maximum ride comfort. The design will allow the vehicle to travel at highway speeds over improved road surfaces and moderate speeds over rough terrain with minimal transfer of road shock and vibration to the vehicle's crew compartment.

Each wheel will have a torsion bar type spring. In addition, each front wheel end will have energy absorbing jounce bumpers to prevent bottoming of the suspension.

The suspension design will have at least 10.00" of total wheel travel and a minimum of 3.75" before suspension bottoms.

The torsion bar anchor lock system allows for simple lean adjustments without the use of shims.

One can adjust for a lean within fifteen minutes per side. Anchor adjustment design is such that it allows for ride height adjustment on each side.

The independent suspension completed durability testing that simulated 140,000 miles of inner city driving.
0087572 Shock Absorbers, KONI, TAK-4,
Qtm/AXT/Imp/Vel/DCF/Enf

FRONT SHOCK ABSORBERS
KONI heavy-duty telescoping shock absorbers will be provided on the front suspension.

Bid #: 933 3

2.12 0000322 Oil Seals, Front Axle FRONT OIL SEALS
Oil seals with viewing window will be provided on the front axle. 0582936 Tires, Front, Goodyear, G289 WHA,
315/80R22.50, 20 ply

FRONT TIRES
Front tires will be Goodyear® 315/80R22.50 radials, 20 ply G289 WHA tread, rated for 20,400 lb maximum axle load and 68 mph maximum speed.
0019575 Wheels, Front, Alcoa, 22.50" x 9.00",
Aluminum, Hub Pilot
The tires will be mounted on Alcoa 22.50" x 9.00" polished aluminum disc wheels with a ten (10) stud, 11.25" bolt circle.
0728303 Axle, Rear, Dana S23-172, 24,000 lb,
Saber/Enforcer

REAR AXLE
The rear axle will be a Dana, Model S23-172, with a capacity of 24,000 lb. 0544253 Top Speed of Vehicle, 68 MPH

TOP SPEED OF VEHICLE
A rear axle ratio will be furnished to allow the vehicle to reach a top speed of 68 mph. 0565379 Suspen, Rear, Single Slipper Spring,
24,000 lb, Saber/Enforcer

REAR SUSPENSION
The rear suspension will be Standens, semi-elliptical, 3.00" wide x 53.00" long, 12-leaf pack with a ground rating of 24,000 lb. The spring hangers will be castings.

The two (2) top leaves will wrap the forward spring hanger pin, and the rear of the spring will be a slipper style end that will ride in a rear slipper hanger. To reduce bending stress due to acceleration and braking, the front eye will be a berlin eye that will place the front spring pin in the horizontal plane within the main leaf.

A steel encased rubber bushing will be used in the spring eye. The steel encased rubber bushing will be maintenance free and require no lubrication.
0000485 Oil Seals, Rear Axle

REAR OIL SEALS
Oil seals will be provided on the rear axle(s).
0587216 Tires, Rear, Goodyear, G622 RSD,
12R22.50, 16 ply, Single

REAR TIRES
Rear tires will be four (4) Goodyear® 12R22.50 radials, 16 ply all season G622 RSD tread, rated for 27,120 lb maximum axle load and 75 mph maximum speed. 0019625 Wheels, Rear, Alcoa, 22.50" x 8.25",
Aluminum, Hub Pilot, Single
The tires will be mounted on Alcoa 22.50" x 8.25" polished aluminum disc wheels with a ten (10) stud 11.25" bolt circle.
0568081 Tire Balancing, Counteract Beads

TIRE BALANCE
All tires will be balanced with Counteract balancing beads. The beads will be inserted into the tire and eliminate the need for wheel weights.
0620570 Tire Pressure Monitoring,
RealWheels, AirSecure, Valve Cap,
Single Axle

TIRE PRESSURE MANAGEMENT
There will be a RealWheels LED AirSecure™ tire alert pressure management system provided, that will monitor each tire's pressure. A sensor will be provided on the valve stem of each tire for a total of six (6) tires.

The sensor will calibrate to the tire pressure when installed on the valve stem for pressures between 10 and 200 psi. The sensor will activate an integral battery operated LED when the pressure of that tire drops 5 to 8 psi.

Removing the cap from the sensor will indicate the functionality of the sensor and battery. If the sensor and battery are in working condition, the LED will immediately start to flash. 0003245 Axle Hub Covers w/center hole, S/S,
Front Axle

FRONT HUB COVERS
Stainless steel hub covers will be provided on the front axle. An oil level viewing window will be provided.
0001960 Axle Hub Covers, Rear, S/S, High
Hat (Pair)

REAR HUB COVERS
A pair of stainless steel high hat hub covers will be provided on rear axle hubs. 0057936 Covers, Lug Nut, Chrome

CHROME LUG NUT COVERS
Chrome lug nut covers will be supplied on front and rear wheels. 0002045 Mud Flap, Front and Rear, Pierce
Logo

MUD FLAPS
Mud flaps with a Pierce logo will be installed behind the front and rear wheels.

Bid #: 933 4

2.13 0617577 Chocks, Wheel, Worden HWG- SB,
Super Gripper

WHEEL CHOCKS
There will be one (1) pair of Worden Safety Products, Model HWG-SB, wheel chocks provided.

Heavy Duty, large molded aluminum wheel chock with solid bottom, natural cast aluminum finish. 0646364 Mounting Brackets, Chocks, Worden
Safety, Model U815T

WHEEL CHOCK BRACKETS
There will be one (1) pair of Worden Safety model U815T mounting wheel chock brackets provided . The brackets will be mounted below compartment LS1. 0010670 ABS Wabco Brake System, Single
rear axle

ANTI-LOCK BRAKE SYSTEM
The vehicle will be equipped with a Meritor WABCO 4S4M, anti-lock braking system. The ABS will provide a 4-channel anti-lock braking control on both the front and rear wheels. A digitally controlled system that utilizes microprocessor technology will control the anti-lock braking system.

Each wheel will be monitored by the system. When any particular wheel begins to lockup, a signal will be sent to the control unit. This control unit then will reduce the braking of that wheel for a fraction of a second and then reapply the brake. This anti-lock brake system will eliminate the lockup of any wheel thus helping to prevent the apparatus from skidding out of control. 0030185 Brakes, Knorr/Bendix 17", Disc,
Front, TAK-4
BRAKES
The service brake system will be full air type.

The front brakes will be Knorr/Bendix disc type with a 17.00" ventilated rotor for improved stopping distance.

The brake system will be certified, third party inspected, for improved stopping distance. 0581433 Brakes, Bendix, Cam, Rear, 16.50 x

7.00"
The rear brakes will be Bendix®, Model ES1657D, 16.50" x 7.00" cam operated with automatic slack adjusters.
0020784 Air Compressor, Brake,
Cummins/Wabco 18.7 CFM

BRAKE SYSTEM AIR COMPRESSOR
The air compressor will be a Cummins/WABCO with 18.7 cubic feet per minute output. 0644232 Brake Reservoirs, 4,272 Cubic Inch
Minimum Capacity, Saber
FR/Enforcer

BRAKE SYSTEM
The brake system will include:

Brake treadle valve
Heated automatic moisture ejector on air dryer
Total air system minimum capacity of 4,272 cubic inches Two (2) air pressure gauges with a red warning light and an audible alarm, that activates when air pressure falls below 60 psi
Spring set parking brake system
Parking brake operated by a push-pull style control valve A parking "brake on" indicator light on instrument panel Park brake relay/inversion and anti-compounding valve, in conjunction with a double check valve system, with an automatic spring brake application at 40 psi A pressure protection valve to prevent all air operated accessories from drawing air from the air system when the system pressure drops below 80 psi (550 kPa) 1/4 turn drain valves on each air tank
The air tank will be primed and painted to meet a minimum 750 hour salt spray test.

To reduce the effects of corrosion, the air tank will be mounted with stainless steel brackets. 0644228 Air Dryer, Wabco System Saver 1200
IWT, Heated, 10" Frame, Standen,
SFR/Enf

BRAKE SYSTEM AIR DRYER
The air dryer will be a WABCO System Saver 1200 IWT, with internal wet tank, spin-on coalescing filter cartridge and 100 watt heater.
0000790 Brake Lines, Nylon BRAKE LINES
Color-coded nylon brake lines will be provided. The lines will be wrapped in a heat protective loom in the chassis areas that are subject to excessive heat. 0000854 Air Inlet, w/Disconnect Coupling

AIR INLET
One (1) air inlet with 3D series male coupling will be provided. It will allow station air to be supplied to the apparatus brake system through a shoreline hose. The inlet will be located forward in the driver side lower step well of cab. A check valve will be provided to prevent reverse flow of air. The inlet will discharge into the "wet" tank of the brake system. A mating female fitting will also be provided with the loose equipment.

Bid #: 933 5

2.14 0736437 Engine, Cummins L9, 450 hp, 1250
lb-ft, W/OBD, EPA 2021, Saber
FR/Enforcer
ENGINE
The chassis will be powered by an electronically controlled engine as described below:

Make:

Cummins
Model:

L9
Power:
450 hp at 2100 rpm
Torque:
1250 lb-ft at 1400 rpm
Governed Speed:
2200 rpm
Emissions Level:

EPA 2021
Fuel:

Diesel
Cylinders:

Six (6)
Displacement:
543 cubic inches (8.9L)
Starter:

Delco 39MT™
Fuel Filters:

Spin-on style primary filter with water separator and water-in-fuel sensor. Secondary spin-on style filter.

The engine will include On-board diagnostics (OBD), which provides self diagnostic and reporting. The system will give the owner or repair technician access to state of health information for various vehicle sub systems. The system will monitor vehicle systems, engine and after treatment. The system will illuminate a malfunction indicator light on the dash console if a problem is detected.
0001244 High Idle w/Electronic Engine,
Custom

HIGH IDLE
A high idle switch will be provided, inside the cab, on the instrument panel, that will automatically maintain a preset engine rpm. A switch will be installed, at the cab instrument panel, for activation/deactivation.

The high idle will be operational only when the parking brake is on and the truck transmission is in neutral. A green indicator light will be provided, adjacent to the switch. The light will illuminate when the above conditions are met. The light will be labeled "OK to Engage High Idle." 0687994 Engine Brake, Jacobs Compression
Brake, Cummins Engine

ENGINE BRAKE
A Jacobs® engine brake is to be installed with the controls located on the instrument panel within easy reach of the driver.

The driver will be able to turn the engine brake system on/off and have a high, medium and low setting.

The engine brake will activate when the system is on and the throttle is released.

The high setting of the brake application will activate and work simultaneously with the variable geometry turbo (VGT) provided on the engine.

The engine brake will be installed in such a manner that when the engine brake is slowing the vehicle the brake lights are activated.

The ABS system will automatically disengage the auxiliary braking device, when required. 0644227 Clutch, Fan, Air Actuated, Saber
FR/Enforcer

CLUTCH FAN
A fan clutch will be provided. The fan clutch will be automatic when the pump transmission is in "Road" position, and constantly engaged when in "Pump" position. 0640477 Air Intake, Metal Screen, Saber
FR/Enforcer

ENGINE AIR INTAKE
The engine air intake will be located above the engine cooling package. It will draw fresh air from the front of the apparatus through the radiator grille.

A stainless steel metal screen will be installed at the inlet of the air intake system that will meet NFPA 1901 requirements.

The air cleaner and stainless steel screen will be easily accessible by tilting the cab. 0794761 Exhaust System, 4", 2017 L9 Engine,
Horizontal, Right Side

EXHAUST SYSTEM
The exhaust system will be stainless steel from the turbo to the engine's aftertreatment device, and will be 4.00" in diameter. The exhaust system will include a single module aftertreatment device to meet current EPA standards. An insulation wrap will be provided on all exhaust pipes between the turbo and aftertreatment device to minimize the heat loss to the aftertreatment device . The exhaust will terminate horizontally ahead of the right side rear wheels. A tailpipe diffuser will be provided to reduce the temperature of the exhaust as it exits. Heat deflector shields will be provided to isolate chassis and body components from the heat of the tailpipe diffuser.

Bid #: 933 6

2.15 0788765 Radiator, Saber FR/Enforcer

RADIATOR
The radiator and the complete cooling system will meet or exceed NFPA and engine manufacturer cooling system standards.

For maximum corrosion resistance and cooling performance, the entire radiator core will be constructed using long life aluminum alloy. The radiator core will consist of aluminum fins, having a serpentine design, brazed to aluminum tubes.

The radiator core will have a minimum front area of 1060 square inches.

Supply tank will be made of heavy duty glass-reinforced nylon and the return tank will be mode of aluminum. Both tanks will be crimped onto the core assembly using header tabs and a compression gasket to complete the radiator core assembly. There will be a full steel frame around the inserts to enhance cooling system durability and reliability.

The radiator will be compatible with commercial antifreeze solutions.

The radiator assembly will be isolated from the chassis frame rails with rubber isolators to prevent the development of leaks caused by twisting or straining when the apparatus operates over uneven terrain.

The radiator will include a de-aeration/expansion tank. For visual coolant level inspection, the radiator will have a built-in sight glass. The radiator will be equipped with a 15 psi pressure relief cap.

A drain port will be located at the lowest point of the cooling system and/or the bottom of the radiator to permit complete flushing of the coolant from the system.

Shields or baffles will be provided to prevent recirculation of hot air to the inlet side of the radiator. 0001090 Cooling Hoses, Rubber

COOLANT LINES
Gates, or Goodyear, rubber hose will be used for all engine coolant lines installed by Pierce Manufacturing.

Hose clamps will be stainless steel constant torque type to prevent coolant leakage. They will expand and contract according to coolant system temperature thereby keeping a constant clamping pressure on the hose.
0001125 Fuel Tank, 65 Gallon, Left Side Fill

FUEL TANK
A 65 gallon fuel tank will be provided and mounted at the rear of the chassis. The tank will be constructed of 12-gauge, hot rolled steel. It will be equipped with swash partitions and a vent. To eliminate the effects of corrosion, the fuel tank will be mounted with stainless steel straps.

A 0.75" drain plug will be located in a low point of the tank for drainage.

A fill inlet will be located on the left hand side of the body and is covered with a hinged, spring loaded, stainless steel door that is marked "Ultra Low Sulfur - Diesel Fuel Only." A 0.50" diameter vent will be installed from tank top to just below fuel fill inlet.

The fuel tank will meet all FHWA 393.67 requirements including a fill capacity of 95 percent of tank volume.
0001129 Lines, Fuel All fuel lines will be provided as recommended by the engine manufacturer. 0618791 DEF Tank, 4.5 Gallon, DS Fill,
Forward of Axle, Common Air Bottle
Door

DIESEL EXHAUST FLUID TANK
A 4.5 gallon diesel exhaust fluid (DEF) tank will be provided and mounted in the driver's side body forward of the rear axle.

A 0.50" drain plug will be provided in a low point of the tank for drainage.

A fill inlet will be provided and marked "Diesel Exhaust Fluid Only". The fill inlet will be located below the air bottle storage behind a common door on the driver side of the vehicle.

The tank will meet the engine manufacturers requirement for 10 percent expansion space in the event of tank freezing.

The tank will include an integrated heater unit that utilizes engine coolant to thaw the DEF in the event of freezing.
0723716 Fuel Priming Pump, Electronic,
Automatic, Cummins, No Swt Req'd

FUEL PRIMING PUMP
A Cummins automatic electronic fuel priming pump will be integrated as part of the engine. 0552712 Not Required, Shutoff Valve, Fuel
Line
0699437 Cooler, Chassis Fuel, Not Req'd.

0690880 No Selection Required From This
Category
0887561 Trans, Allison 6th Gen, 3000 EVS P,
Imp/Vel/SFR/Enf

TRANSMISSION
An Allison 6th generation, Model EVS 3000P, electronic torque converting automatic transmission will be provided.

Two (2) PTO openings will be located on both sides of converter housing (positions 4 o'clock and 8 o'clock) as viewed from the rear.

A transmission temperature gauge with amber light and audible alarm will be installed on the cab dash.

Bid #: 933 7

2.16 0625329 Transmission, Shifter, 5-Spd, Push
Button, 3000 EVS

TRANSMISSION SHIFTER
A five (5)-speed push button shift module will be mounted to right of driver on console. Shift position indicator will be indirectly lit for after dark operation.

The transmission ratio will be:
1st

3.49 to 1.00
2nd

1.86 to 1.00
3rd

1.41 to 1.00
4th

1.00 to 1.00
5th

0.75 to 1.00
R

5.03 to 1.00
0684459 Transmission Oil Cooler, Modine,
External

TRANSMISSION COOLER
A Modine plate and fin transmission oil cooler will be provided using engine coolant to control the transmission oil temperature.
0001370 Driveline, Spicer 1710 DRIVELINE
Drivelines will be a heavy-duty metal tube and be equipped with Spicer® 1710 universal joints.

The shafts will be dynamically balanced before installation.

A splined slip joint will be provided in each driveshaft where the driveline design requires it. The slip joint will be coated with Glidecoat® or equivalent. 0669988 Steering, Sheppard M110 w/Tilt,
TAK-4, Eaton Pump, w/Cooler

STEERING
Dual Sheppard, Model M110, steering gears, with integral heavy-duty power steering, will be provided. For reduced system temperatures, the power steering will incorporate an air to oil cooler and an Eaton, Model VN20, hydraulic pump with integral pressure and flow control. All power steering lines will have wire braded lines with crimped fittings.

A tilt and telescopic steering column will be provided to improve fit for a broader range of driver configurations.
0509229 Steering Wheel, 2 Spoke STEERING WHEEL
The steering wheel will be 18.00" in diameter, have tilting and telescoping capabilities, and a 2- spoke design.
0559647 Pierce Logo on Horn Button

0606441 Bumper, 19" Extended, Steel
Painted, Saber FR/Enforcer

BUMPER
A one (1)-piece bumper manufactured from 0.25" formed steel with a 0.38" bend radius will be provided. The bumper will be a minimum of 10.00" high with a 1.50" top and bottom flange, and will extend 19.00" from the face of the cab. The bumper will be 95.28" wide with 45 degree corners and side plates. The bumper will be metal finished and painted job color.

To provide adequate support strength, the bumper will be mounted directly to the front of the C channel frame. The frame will be a bolted modular extension frame constructed of 50,000 psi tensile steel.

Gravel Pan
A gravel pan, constructed of bright aluminum treadplate, will be furnished between the bumper and the cab face. The pan will be properly supported from the underside to prevent flexing and vibration.
0640197 Tray, Hose, Center, 19" Bumper,
Outside Air Horns

CENTER HOSE TRAY
A hose tray, constructed of aluminum, will be placed in the center of the bumper extension.

The tray will have a capacity of 125' of 1.75" double jacket cotton-polyester hose.

Black rubber grating will be provided at the bottom of the tray. Drain holes are also provided. 0633479 Hose Restraint, Bumper Tray, Velcro
Straps, Pair
Center Hose Tray Restraint
There will be one (1) pair of hose tray restraint straps located over the center mounted tray.

The restraints will be a pair of 2.00" wide black nylon straps with Velcro® fasteners provided. The strap(s) will be used to secure the hose in the tray.
0614646 No Lift & Tow Package, Imp/Vel,
AXT, SFR/Enf
0002270 Tow Hooks, Chrome

TOW HOOKS
Two (2) chromed steel tow hooks will be installed under the bumper and attached to the front frame members. The tow hooks will be designed and positioned to allow up to a 6,000 lb straight horizontal pull in line with the centerline of the vehicle. The tow hooks will not be used for lifting of the apparatus.

Bid #: 933 8

2.17 0698960 Coating, Top Flange, Front Bumper,
Outside Exterior, UL-LX Coating,
Black

FRONT BUMPER UL-LX COATING
Protective black UL-LX® coating will be provided on the outside exterior of the top front bumper flange. It will not be sprayed on the underside of the flange.

The lining will be properly installed by an authorized UL-LX dealer. 0625650 Cab, Enforcer, 7000

CAB
The Enforcer cab will be designed specifically for the fire service and manufactured by the chassis builder.

The cab will be built by the apparatus manufacturer in a facility located on the manufacturer's premises.

For reasons of structural integrity and enhanced occupant protection, the cab will be a heavy duty design, constructed to the following minimal standards.

The cab will have 12 main vertical structural members located in the A-pillar (front cab corner posts), B-pillar (side center posts), C-pillar (rear corner posts), and rear wall areas. The A-pillar will be constructed of solid A356-T5 aluminum castings. The B-pillar and C-pillar will be constructed from 0.13" wall extrusions. The rear wall will be constructed of two (2) 2.00" x 2.00" outer aluminum extrusions and two (2) 2.00" x 1.00" inner aluminum extrusions. All main vertical structural members will run from the floor to 4.625" x 3.864" x 0.090" thick roof extrusions to provide a cage-like structure with the A-pillar and roof extrusions being welded into a 0.25" thick corner casting at each of the front corners of the roof assembly.

The front of the cab will be constructed of a 0.13" firewall plate, covered with a 0.090" front skin (for a total thickness of 0.22"), and reinforced with a full width x 0.50" thick cross-cab support located just below the windshield and fully welded to the engine tunnel. The cross-cab support will run the full width of the cab and weld to each A-pillar, the 0.13" firewall plate, and the front skin.

The cab floors will be constructed of 0.125" thick aluminum plate and reinforced at the firewall with an additional 0.25" thick cross-floor support providing a total thickness of 0.375" of structural material at the front floor area. The front floor area will also be supported with two (2) triangular

0.30" wall extrusions that also provides the mounting point for the cab lift. This tubing will run from the floor wireway of the cab to the engine tunnel side plates, creating the structure to support the forces created when lifting the cab.

The cab will be 96.00" wide (outside door skin to outside door skin) to maintain maximum maneuverability.

The overall height (from the cab roof to the ground) of approximately 99.00". The overall height listed will be calculated based on a truck configuration with the lowest suspension weight rating, the smallest diameter tires for the suspension, no water weight, no loose equipment weight, and no personnel weight. Larger tires, wheels, and suspension will increase the overall height listed.

The floor to ceiling height inside the crew cab will be 54.50" in the center and outboard positions.

The crew cab floor will measure 46.00" from the rear wall to the back side of the rear facing seat risers.

The medium block engine tunnel, at the rearward highest point (knee level), will measure 61.50" to the rear wall. The big block engine tunnel will measure 51.50" to the rear wall.

The crew cab will be a totally enclosed design with the interior area completely open to improve visibility and verbal communication between the occupants.

The cab will be a full tilt cab style.

A 3-point cab mount system with rubber isolators will improve ride quality by isolating chassis vibrations from the cab.

CAB ROOF DRIP RAIL
For enhanced protection from inclement weather, a drip rail will be furnished on the sides of the cab. The drip rail will be painted to match the cab roof, and bonded to the sides of the cab. The drip rail will extend the full length of the cab roof.

INTERIOR CAB INSULATION
The cab will include 1.00" insulation in the ceiling, 1.50" insulation in the side walls, and 2.00" insulation in the rear wall to maximize acoustic absorption and thermal insulation.

FENDER LINERS
Full circular inner fender liners in the wheel wells will be provided.

PANORAMIC WINDSHIELD
A one (1)-piece safety glass windshield will be provided with over 2,775 square inches of clear viewing area. The windshield will be full width and will provide the occupants with a panoramic view. The windshield will consist of three (3) layers: outer light, middle safety laminate, and inner light. The outer light layer will provide superior chip resistance. The middle safety laminate layer will prevent the windshield glass pieces from detaching in the event of breakage. The inner light will provide yet another chip resistant layer. The cab windshield will be bonded to the aluminum windshield frame using a urethane adhesive. A custom frit pattern will be applied on the outside perimeter of the windshield for a finished automotive appearance.

WINDSHIELD WIPERS
Three (3) electric windshield wipers with washer will be provided that meet FMVSS and SAE requirements.

The washer reservoir will be able to be filled without raising the cab. 0647919 Engine Tunnel, ISL, Saber
FR/Enforcer

ENGINE TUNNEL
Engine hood side walls will be constructed of 0.375" aluminum. The top will be constructed of

0.125" aluminum and will be tapered at the top to allow for more driver and passenger elbow room.

The engine hood will be insulated for protection from heat and sound. The noise insulation keeps the dBA level within the limits stated in the current NFPA 1901 standards.

The engine tunnel will be no higher than 17.00" off the crew cab floor.

Bid #: 933 9

2.18 0633594 Rear Wall, Interior, Adjustable
Seating

INTERIOR CREW CAB REAR WALL ADJUSTABLE SEATING (PATENT PENDING) The interior rear wall of the crew cab will have mounting holes every 2.75" to allow for adjustability of the forward facing crew cab seating along the rear wall. Seats will be adjustable with use of simple hand tools allowing departments flexibility of their seating arrangement should their department needs change.
0632103 Rear Wall, Exterior, Cab, Saber
FR/Enforcer

CAB REAR WALL EXTERIOR COVERING
The exterior surface of the rear wall of the cab will be overlaid with bright aluminum treadplate except for areas that are not typically visible when the cab is lowered. 0644201 Cab Lift, Elec/Hyd, Saber
FR/Enforcer

CAB LIFT
A hydraulic cab lift system will be provided consisting of an electric powered hydraulic pump, dual lift cylinders, and necessary hoses and valves.

Lift controls will be located on the right side pump panel or front area of the body in a convenient location.

The cab will be capable of tilting 43 degrees to accommodate engine maintenance and removal.

The cab will be locked down by a 2-point normally closed spring loaded hook type latch that fully engages after the cab has been lowered. The system will be hydraulically actuated to release the normally closed locks when the cab lift control is in the raised position and cab lift system is under pressure. When the cab is completely lowered and system pressure has been relieved, the spring loaded latch mechanisms will return to the normally closed and locked position.

The hydraulic cylinders will be equipped with a velocity fuse that protects the cab from accidentally descending when the control is located in the tilt position.

For increased safety, a redundant mechanical stay arm will be provided that must be manually put in place on the left side between the chassis and cab frame when the cab is in the raised position. This device will be manually stowed to its original position before the cab can be lowered.

Cab Lift Interlock
The cab lift system will be interlocked to the parking brake. The cab tilt mechanism will be active only when the parking brake is set and the ignition switch is in the on position. If the parking brake is released, the cab tilt mechanism will be disabled. 0695930 Grille, Bright Finished, Front of Cab,
Enforcer
GRILLE
A bright finished aluminum mesh grille screen, inserted behind a bright finished grille surround, will be provided on the front center of the cab.
0647932 Not Required, Trim, S/S Band,
Across Cab Face, AXT/Dash
CF/Saber/Enforcer
0087357 Molding, Chrome on Side of Cab

SIDE OF CAB MOLDING
Chrome molding will be provided on both sides of cab.
0772130 Mirrors, Retrac, West Coast Style,
Htd/Rmt, w/Htd/Rmt Convex, Marker
Light

MIRRORS
A Retrac, dual vision, motorized, west coast style mirror, with chrome finish, will be mounted on each side of the front cab door with spring loaded retractable arms. The flat glass and convex glass will be heated and adjustable with remote control within reach of the driver.

An amber marker light will be provided on each mirror head. 0648171 Door, Half-Height, Saber FR/Enforcer
4-Door Cab, Level Roof
DOORS
To enhance entry and egress to the cab, the forward cab door openings will be a minimum of

37.50" wide x 63.37" high. The crew cab doors will be located on the sides of the cab and will be constructed in the same manner as the forward cab doors. The crew cab door openings will be a minimum of 34.30" wide x 63.37" high.

The forward cab and crew cab doors will be constructed of extruded aluminum with a nominal material thickness of 0.093". The exterior door skins will be constructed from 0.090" aluminum.

A customized, vertical, pull-down type door handle will be provided on the exterior of each cab door. The finish of the door handle will be chrome/black. The exterior handle will be designed specifically for the fire service to prevent accidental activation, and will provide 4.00" wide x 2.00" deep hand clearance for ease of use with heavy gloved hands.

Each door will also be provided with an interior flush, open style paddle handle that will be readily operable from fore and aft positions, and be designed to prevent accidental activation. The interior handles will provide 4.00" wide x 1.25" deep hand clearance for ease of use with heavy gloved hands.

The cab doors will be provided with both interior (rotary knob) and exterior (keyed) locks exceeding FMVSS standards. The keys will be Model 751. The locks will be capable of activating when the doors are open or closed. The doors will remain locked if locks are activated when the doors are opened, then closed.

A full length, heavy duty, stainless steel, piano-type hinge with a 0.38" pin and 11 gauge leaf will be provided on all cab doors. There will be double automotive-type rubber seals around the perimeter of the door framing and door edges to ensure a weather-tight fit.

A chrome handle will be provided on the inside of each cab door for ease of entry.

A red webbed grab handle will be installed on the crew cab door stop strap. The grab handles will be securely mounted.

The bottom cab step at each cab door location will be located below the cab doors and will be exposed to the exterior of the cab.

Bid #: 933 10 2.19
0655543 Door Panel, Brushed Stainless Steel,
Saber/Enforcer 4-Door Cab
Door Panels
The inner cab door panels will be constructed out of brushed stainless steel. 0528958 Not Required, Controls, Electric
Window, AXT, Quantum, Saber,
Enforcer, Dash CF

MANUAL CAB DOOR WINDOWS
All cab entry doors will contain a conventional roll down window. 0638310 Steps, 4-Door Cab, Saber
FR/Enforcer

CAB STEPS
The forward cab and crew cab access steps will be a full size two (2) step design to provide largest possible stepping surfaces for safe ingress and egress. The bottom steps will be designed with a grip pattern punched into bright aluminum treadplate material to provide support, slip resistance, and drainage. The bottom steps will be a bolt-in design to minimize repair costs should they need to be replaced. The forward cab steps will be a minimum 25.00" wide, and the crew cab steps will be 21.65" wide with a 10.00" minimum depth. The inside cab steps will not exceed 16.50" in height.

The vertical surfaces of the step well will be aluminum treadplate. 0770194 Handrail, Exterior, Knurled, Alum, 4-
Door Cab

CAB EXTERIOR HANDRAILS
A 1.25" diameter slip-resistant, knurled aluminum handrail will be provided adjacent to each cab and crew cab door opening to assist during cab ingress and egress. 0892638 Lights, Cab & Crw Cab Acs Stps,
P25, LED w/Bezel, 6lts

STEP LIGHTS
There will be six (6) white LED step lights with chrome housing installed for cab and crew cab access steps.

One (1) light for the left access steps.

Two (2) lights for the left side crew cab access steps.

Two (2) lights for the right side crew cab access steps.

One (1) light for the right side access step.

In order to ensure exceptional illumination, each light will provide a minimum of 25 foot-candles (fc) covering an entire 15" x 15" square placed ten (10) inches below the light and a minimum of

1.5 fc covering an entire 30" x 30" square at the same ten (10) inch distance below the light.

The lights will be activated when the battery switch is on and the adjacent door is opened. 0583698 Fenders, S/S on cab, Extra Wide,
Saber/Enf

FENDER CROWNS
Stainless steel fender crowns will be installed at the cab wheel openings. 0637984 Window, Side of C/C, Fixed, Saber
FR/Enforcer

CREW CAB WINDOWS
One (1) fixed window with tinted glass will be provided on each side of the cab, to the rear of the front cab door. The windows will be sized to enhance light penetration into the cab interior. The windows will measure 18.70" wide x 23.75" high.
0722796 Dash, Poly, Saber FR/Enforcer

CAB DASH
The driver side dash, switch panel located to the right of the driver, and center console will be an easily removable high impact resistant polymer cover.

The instrument gauge cluster will be surrounded with a high impact ABS plastic contoured to the same shape of the instrument gauge cluster.

The officer side dash will be a flat top design with an upper beveled edge to provide easy maintenance and will be constructed out of aluminum and painted to match the cab interior. 0607217 Mounting Provisions, 3/16" Alum, Full
Engine Tunnel, Saber FR/Enforcer

MOUNTING PLATE ON ENGINE TUNNEL
Equipment installation provisions will be installed on the engine tunnel.

A 0.188" smooth aluminum plate will be bolted to the top surface of the engine tunnel. The plate will follow the contour of the engine tunnel and will run the entire length of the engine tunnel. The plate will be spaced off the engine tunnel 1.00" to allow for wire routing below the plate.

The mounting surface will be painted to match the cab interior. 0892120 SP Mounting Plate, 3/16" Aluminum, (2)
Cup Holder Cutouts,Abv Rec Ctr
Dash Console

MOUNTING PLATE
There will be a 0.188" aluminum mounting plate provided above the recessed center dash console bin.

The mounting surface will include two (2) 3.25" diameter cutouts for cup holders over center recessed bin of dashboard.

The mounting surface will be painted to match the cab interior.

Bid #: 933 11 2.20
0750824 Cab Interior, Vinyl Headliner, Saber
FR/Enforcer, CARE

CAB INTERIOR
The cab interior will be constructed of primarily metal (painted aluminum) to withstand the severe duty cycles of the fire service.

The engine tunnel will be padded and covered, on the top and sides, with dark silver gray 36 ounce leather grain vinyl resistant to oil, grease, and mildew.

For durability and ease of maintenance, the cab interior side walls will be painted aluminum. The rear wall will be painted aluminum.

The headliner will be installed in both forward and rear cab sections. Headliner material will be vinyl. A sound barrier will be part of its composition. Material will be installed on an aluminum sheet and securely fastened to interior cab ceiling.

The forward portion of the cab headliner will permit easy access for service of electrical wiring or other maintenance needs.

All wiring will be placed in metal raceways.

CAB INTERIOR UPHOLSTERY
The cab interior upholstery will be 36 oz dark silver gray vinyl. 0753903 Cab Interior, Paint Color, Saber
FR/Enforcer

CAB INTERIOR PAINT
The cab interior metal surfaces, excluding the rear heater panels, will be painted fire smoke gray, vinyl texture paint.

The rear heater panels will be painted black, vinyl textured paint. 0052100 Floor, Rubber Padded, Cab & Crew
Cab, Saber/Enforcer

CAB FLOOR
The cab and crew cab floor areas will be covered with Polydamp™ acoustical floor mat consisting of a black pyramid rubber facing and closed cell foam decoupler.

The top surface of the material has a series of raised pyramid shapes evenly spaced, which offer a superior grip surface. Additionally, the material has a 0.25" thick closed cell foam (no water absorption) which offers a sound dampening material for reducing sound levels. 0722696 HVAC, Enforcer, CARE

DEFROST/AIR CONDITIONING SYSTEM
A ceiling mounted combination heater, defroster and air conditioning system will be installed in the cab above the engine tunnel area.

Cab Defroster
A 54,000 BTU heater-defroster unit with 690 SCFM of air flow will be provided inside the cab. The heater-defrost will be installed in the forward portion of the cab ceiling. Air outlets will be strategically located in the cab header extrusion per the following:

One (1) adjustable will be directed towards the left side cab window One (1) adjustable will be directed towards the right side cab window Six (6) fixed outlets will be directed at the windshield The defroster will be capable of clearing 98 percent of the windshield and side glass when tested under conditions where the cab has been cold soaked at 0 degrees Fahrenheit for 10 hours, and a 2 ounce per square inch layer of frost/ice has been able to build up on the exterior windshield.

The defroster system will meet or exceed SAE J382 requirements.

Cab/Crew Auxiliary Heater
There will be one (1) 31,000 BTU auxiliary heater with 560 SCFM of air flow provided in each outboard rear facing seat risers with a dual scroll blower. An aluminum plenum incorporated into the cab structure used to transfer heat to the forward positions.

Air Conditioning
A condenser will be a 59,644 BTU output that meets and exceeds the performance specification will be mounted on the radiator.

The air conditioning system will be capable of cooling the average cab temperature from 100 degrees Fahrenheit to 75 degrees Fahrenheit at 50 percent relative humidity within 30 minutes.

The cooling performance test will be run only after the cab has been heat soaked at 100 degrees Fahrenheit for a minimum of 4 hours.

The evaporator unit will be installed in the rear portion of the cab ceiling over the engine tunnel.

The evaporator will include one (1) high performance heating core, one (1) high performance cooling core with (1) plenum directed to the front and one (1) plenum directed to the rear of the cab. The rear plenum will be covered with a formed plastic cover.

The evaporator unit will have a 52,000 BTU at 690 SCFM rating that meets and exceeds the performance specifications.

Adjustable air outlets will be strategically located on the forward plenum cover per the following:

Four (4) will be directed towards the seating position on the left side of the cab Four (4) will be directed towards the seating position on the right side of the cab Adjustable air outlets will be strategically located on the rear plenum cover per the following:

Minimum of five (5) will be directed towards crew cab area A high efficiency particulate air (HEPA) filter will be included for the system. Access to the filter cover will be secured with four (4) screws.

The air conditioner refrigerant will be R-134A and will be installed by a certified technician.

Climate Control
An automotive style controller will be provided to control the heat and air conditioning system within the cab. The controller will have three (3) functional knobs for fan speed, temperature, and air flow distribution (front to rear) control.

The system will control the temperature of the cab and crew cab automatically by pushing the center of the fan speed control knob. Rotate the center temperature control knob to set the cab and crew cab temperature.

The AC system will be manually activated by pushing the center of the temperature control knob.

Pushing the center of the air flow distribution knob will engage the AC for max defrost, setting the fan speeds to 100 percent and directing all air flow to the overhead forward position.

The system controller will be located within panel position #12.

Gravity Drain Tubes
Two (2) condensate drain tubes will be provided for the air conditioning evaporator. The drip pan will have two (2) drain tubes plumbed separately to allow for the condensate to exit the drip pan.

No pumps will be provided.

Bid #: 933 12 2.21
0639675 Sun Visor, Smoked Lexan, AXT,
Imp/Vel, Saber FR/Enforcer

SUN VISORS
Two (2) smoked Lexan™ sun visors will be provided. The sun visors will be located above the windshield with one (1) mounted on each side of the cab.

There will be a black plastic thumb latch provided to help secure each sun visor in the stowed position.
0622887 Grab Handles, Driver Door Post,
Officer Door Post Low, Saber
FR/Enforcer

GRAB HANDLE
A black rubber covered grab handle will be mounted on the door post of the driver and officer's side cab door to assist in entering the cab. The officer's side grab handle will be mounted on the lower portion of the door post. The grab handle will be securely mounted to the post area between the door and windshield.
0002526 Light, Engine Compt, All Custom
Chassis

ENGINE COMPARTMENT LIGHT
An engine compartment light will be installed under the engine hood, of which the switch is an integral part. Light will have a .125" diameter hole in its lens to prevent moisture retention. 0631830 Fluid Check Access, Saber
FR/Enforcer, Arrow XT

ACCESS TO ENGINE DIPSTICKS
For access to the engine oil and transmission fluid dipsticks, there will be a door on the engine tunnel, inside the crew cab. The door will be on the rear wall of the engine tunnel, on the vertical surface.

The engine oil dipstick will allow for checking only. The transmission dipstick will allow for both checking and filling.

The door will have a rubber seal for thermal and acoustic insulation. One (1) flush lift and turn latch will be provided on the access door.
0002508 Map Box, 3 Bin/30 deg Slant, Custom
Chassis

MAP BOX
There will be one (1) map box(es) with three (3) bins, open at top. The map box(es) will be installed at final inspection. The map box(es) will be divided into three (3) bins, each being 12.50" wide x 3.00" high x 12.00" deep. Each bin will slant 30 degrees from horizontal. The map box(es) will be constructed of 0.125" aluminum and will be painted to match the cab interior. 0599959 Straps, Velcro, Map Box, Custom
Chassis

VELCRO STRAP(S) FOR MAP BOX
There will be one (1) Velcro® strap(s) installed on the map box. 0583039 Not Required, Side Roll and Frontal
Impact Protection
0622617 Seating Capacity, 6 Seats

SEATING CAPACITY
The seating capacity in the cab will be six (6).
0636957 Seat, Driver, Pierce PSV, Air Ride,
High Back, Saber FR/Enforcer

DRIVER SEAT
A seat will be provided in the cab for the driver. The seat design will be a cam action type, with air suspension. For increased convenience, the seat will include a manual control to adjust the horizontal position (6.00" travel). The manual horizontal control will be a towel-bar style located below the forward part of the seat cushion. To provide flexibility for multiple driver configurations, the seat will have an adjustable reclining back. The seat back will be a high back style with side bolster pads for maximum support. For optimal comfort, the seat will be provided with 17.00" deep foam cushions designed with EVC (elastomeric vibration control).

The seat will be furnished with a 3-point, shoulder type seat belt. 0636946 Seat, Officer, Pierce PSV, Fixed,
SCBA, Saber FR/Enforcer

OFFICER SEAT
A seat will be provided in the cab for the passenger. The seat will be a fixed type with no suspension. For optimal comfort, the seat will be provided with 17.00" deep foam cushions designed with EVC (elastomeric vibration control).

The seat back will be an SCBA back style with 5 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location.

The seat will be furnished with a 3-point, shoulder type seat belt. 0620420 Radio Compartment, Below Non-Air
Ride Seat, Saber FR/Enforcer

RADIO COMPARTMENT
A radio compartment will be provided under the officer's seat.

The inside compartment dimensions will be 16.00" wide x 7.50" high x 15.00" deep, with the back of the compartment angled up to match the cab structure.

A drop-down door with one (1) flush lift and turn latch will be provided for access.

The compartment will be constructed of smooth aluminum and painted to match the cab interior.

Bid #: 933 13 2.22
0632852 Seat, Rear Facing C/C, DS Outboard,
Pierce PSV, SCBA, Saber
FR/Enforcer

REAR FACING DRIVER SIDE OUTBOARD SEAT
There will be one (1) rear facing seat provided at the driver side outboard position in the crew cab. For optimal comfort, the seat will be provided with 15.00" deep foam cushions designed with EVC (elastomeric vibration control).

The seat back will be an SCBA back style with 5 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location.

The seat will be furnished with a 3-point, shoulder type seat belt. 0102783 Not Required, Seat, Rr Facing C/C,
Center
0632848 Seat, Rear Facing C/C, PS Outboard,
Pierce PSV, SCBA, Saber
FR/Enforcer

REAR FACING PASSENGER SIDE OUTBOARD SEAT
There will be one (1) rear facing seat provided at the passenger side outboard position in the crew cab. For optimal comfort, the seat will be provided with 15.00" deep foam cushions designed with EVC (elastomeric vibration control).

The seat back will be an SCBA back style with 5 degree fixed recline angle. The SCBA cavity will be adjustable from front to rear in 1.00" increments, to accommodate different sized SCBA cylinders. Moving the SCBA cavity will be accomplished by unbolting, relocating, and re-bolting it in the desired location.

The seat will be furnished with a 3-point, shoulder type seat belt. 0632945 Seat, Forward Facing C/C, DS
Outboard, Flip Up Cushion, Saber
FR/Enforcer

FORWARD FACING DRIVER SIDE OUTBOARD SEAT
There will be one (1) forward facing flip-up seat provided at the driver side outboard position in the crew cab. The seat back will have a plywood backing, covered with foam padded upholstery.

The seat bottom will be constructed of a piece of plywood covered with foam rubber and upholstery. The bottom cushion will have its bottom covered with brushed stainless steel, for a pleasant appearance when the seat bottom is in the up position.

The seat will be furnished with a 3-point, shoulder type seat belt. 0783479 Cabinet, Forward Facing, Center,

38.50 W x 50 H x 28 D, Roll, SFR/Enf

FORWARD FACING CENTER CABINET
A forward facing cabinet will be provided in the crew cab at the center position.

The cabinet will be 38.50" wide x 50.00" high x 28.00" deep with one (1) Amdor rollup door with anodized finish, non-locking. The frame to frame opening of the cabinet will be 36.00" wide x

44.75" high. The minimum clear door opening will be 33.25" wide x 38.87" high.

The cabinet will include one (1) infinitely adjustable shelf with a 0.75" up-turned lippainted to match the cab interior.

The cabinet will include no louvers.

The cabinet will be constructed of smooth aluminum, and painted to match the cab interior.

Cabinet Light
There will be one (1) white LED strip light installed on the left side of the interior cabinet door opening and one (1) white LED strip light installed on the right side of the interior cabinet door opening. The lighting will be controlled by an automatic door switch. 0632877 Seat, Forward Facing C/C, PS
Outboard, Flip Up Cushion, Saber
FR/Enforcer

FORWARD FACING PASSENGER SIDE OUTBOARD SEAT
There will be one (1) forward facing flip-up seat provided at the passenger side outboard position in the crew cab. The seat back will have a plywood backing, covered with foam padded upholstery. The seat bottom will be constructed of a piece of plywood covered with foam rubber and upholstery. The bottom cushion will have its bottom covered with brushed stainless steel, for a pleasant appearance when the seat bottom is in the up position.

The seat will be furnished with a 3-point, shoulder type seat belt. 0566653 Upholstery, Seats In Cab, Turnout
Tuff

SEAT UPHOLSTERY
All seat upholstery will be gray Turnout Tuff material. 0065740 Bracket, Air Bottle, Zico, ULLH, Load
& Lock, In Cab Seats

AIR BOTTLE HOLDERS
All SCBA type seats in the cab will have a Ziamatic, Model ULLH, SCBA holder bracket. This bracket will be compliant with the current NFPA 1901 standards and will include a back plate, two (2) seats, a footplate and the Model LLS (Load & Lock) strap to hold the bottle in the bracket. The bracket seats will be a "one size fits all" style seat and will accommodate SCBA cylinders from the high pressure 30-minute to the high pressure 60-minute. Seats will be adjustable up and down by unbolting, relocating, and re-bolting in the desired position.

Bid #: 933 14 2.23
0603866 Seat Belt, Dual Retractor,
ReadyReach, Saber FR/Enforcer

SEAT BELTS
All cab and tiller cab (if applicable) seating positions will have red seat belts. To provide quick, easy use for occupants wearing bunker gear, the female buckle and seat belt webbing length will meet or exceed the current edition of NFPA 1901 and CAN/ULC - S515 standards.

The 3-point shoulder type seat belts will include height adjustment. This adjustment will optimize the belts effectiveness and comfort for the seated firefighter. The 3-point shoulder type seat belts will be furnished with dual automatic retractors that will provide ease of operation in the normal seating position.

The 3-point shoulder type belts will also include the ReadyReach D-loop assembly to the shoulder belt system. The ReadyReach feature adds an extender arm to the D-loop location placing the D-loop in a closer, easier to reach location.

Any flip up seats will include a 3-point shoulder type belts only.

To ensure safe operation, the seats will be equipped with seat belt sensors in the seat cushion and belt receptacle that will activate an alarm indicating a seat is occupied but not buckled. 0602464 Helmet Storage, Provided by Fire
Department, NFPA 2016

HELMET STORAGE PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, section 14.1.7.4.1 requires a location for helmet storage be provided.

There is no helmet storage on the apparatus as manufactured. The fire department will provide a location for storage of helmets.
0647647 Lights, Dome, FRP Dual LED 4 Lts

CAB DOME LIGHTS
There will be four (4) dual LED dome lights with black bezels provided. Two (2) lights will be mounted above the inside shoulder of the driver and officer and two (2) lights will be installed and located, one (1) on each side of the crew cab.

The color of the LED's will be red and white.

The white LED's will be controlled by the door switches and the lens switch.

The color LED's will be controlled by the lens switch.

In order to ensure exceptional illumination, each white LED dome light will provide a minimum of

10.1 foot-candles (fc) covering an entire 20.00" x 20.00" square seating position when mounted

40.00" above the seat.
0602637 Portable Hand Light, Provided by Fire
Dept, Pumper NFPA 2016
Classification

PORTABLE HAND LIGHTS, PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, section 5.9.4 requires two portable hand lights mounted in brackets fastened to the apparatus.

The hand lights are not on the apparatus as manufactured. The fire department will provide and mount these hand lights.
0644187 Cab Instruments, Black Gauges,
Black Bezels, Saber FR/Enforcer

CAB INSTRUMENTATION
The cab instrument panel will include gauges, telltale indicator lamps, control switches, alarms, and a diagnostic panel. The function of the instrument panel controls and switches will be identified by a label adjacent to each item. Actuation of the headlight switch will illuminate the labels in low light conditions. Telltale indicator lamps will not be illuminated unless necessary. The cab instruments and controls will be conveniently located within the forward cab section, forward of the driver. The gauge assembly and switch panels are designed to be removable for ease of service and low cost of ownership.

Gauges
The gauge panel will include the following ten (10) black faced gauges with black bezels to monitor vehicle performance:

Voltmeter gauge (volts):

Low volts (11.8 VDC)
Amber telltale light on indicator light display with steady tone alarm High volts (15.5 VDC)
Amber telltale light on indicator light display with steady tone alarm Engine Tachometer (RPM)
Speedometer MPH (Major Scale), KM/H (Minor Scale)
Fuel level gauge (Empty - Full in fractions):

Low fuel (1/8 full)
Amber indicator light in gauge dial with steady tone alarm Engine Oil pressure Gauge (PSI):

Low oil pressure to activate engine warning lights and alarms Red indicator light in gauge dial with steady tone alarm Front Air Pressure Gauges (PSI):

Low air pressure to activate warning lights and alarm
Red indicator light in gauge dial with steady tone alarm Rear Air Pressure Gauges (PSI):

Low air pressure to activate warning lights and alarm
Red indicator light in gauge dial with steady tone alarm Transmission Oil Temperature Gauge (Fahrenheit):

High transmission oil temperature activates warning lights and alarm Amber indicator light in gauge dial with steady tone alarm Engine Coolant Temperature Gauge (Fahrenheit):

High engine temperature activates an engine warning light and alarms Red indicator light in gauge dial with steady tone alarm Diesel Exhaust Fluid Level Gauge (Empty - Full in fractions):

Low fluid (1/8 full)
Amber indicator light in gauge dial
Indicator Lamps
To promote safety, the following telltale indicator lamps will be located on the instrument panel in clear view of the driver. The indicator lamps will be "dead-front" design that is only visible when active. The colored indicator lights will have descriptive text or symbols.

The following amber telltale lamps will be present:

Bid #: 933 15 2.24
Low coolant
Trac cntl (traction control) (where applicable)
Check engine
Check trans (check transmission)
Air rest (air restriction)
DPF (engine diesel particulate filter regeneration)
HET (engine high exhaust temperature) (where applicable) ABS (antilock brake system)
MIL (engine emissions system malfunction indicator lamp) (where applicable) Regen inhibit (engine emissions regeneration inhibit) (where applicable) Side roll fault (where applicable)
Front air bag fault (where applicable)
Aux brake overheat (auxiliary brake overheat) (where applicable) The following red telltale lamps will be present:

Ladder rack down
Parking brake
Stop engine
The following green telltale lamps will be present:

Left turn
Right turn
Battery on
Ignition
Aux brake (auxiliary brake engaged) (where applicable)
The following blue telltale lamps will be present:

High beam
Alarms
Audible steady tone warning alarm: A steady audible tone alarm will be provided whenever a warning condition is active.

Indicator Lamp and Alarm Prove-Out
A system will be provided which automatically tests telltale indicator lights and alarms located on the cab instrument panel. Telltale indicators and alarms will perform prove-out for 3 to 5 seconds when the ignition switch is moved to the on position with the battery switch on.

Control Switches
For ease of use, the following controls will be provided immediately adjacent to the cab instrument panel within easy reach of the driver. All switches will have backlit labels for low light applications.

Headlight/Parking light switch: A three (3)-position maintained rocker switch will be provided. The first switch position will deactivate all parking and headlights. The second switch position will activate the parking lights. The third switch will activate the headlights.

Panel back lighting intensity control switch: A three (3)-position momentary rocker switch will be provided. Pressing the top half of the switch, "Panel Up" increases the panel back lighting intensity and pressing the bottom half of the switch, "Panel Down" decreases the panel back lighting intensity. Pressing the half or bottom half of the switch several times will allow back lighting intensity to be gradually varied from minimum to maximum intensity level for ease of use.

Ignition switch: A three (3)-position maintained/momentary rocker switch will be provided. The first switch position will turn off and deactivate vehicle ignition. The second switch position will activate vehicle ignition and will perform prove-out on the telltale indicators and alarms for 3 to 5 seconds after the switch is turned on. A green indicator lamp is activated with vehicle ignition.

The third momentary position will temporarily silence all active cab alarms. An alarm "chirp" may continue as long as alarm condition exists. Switching ignition to off position will terminate the alarm silence feature and reset function of cab alarm system.

Engine start switch: A two (2)-position momentary rocker switch will be provided. The first switch position is the default switch position. The second switch position will activate the vehicle's engine. The switch actuator is designed to prevent accidental activation.

Hazard switch will be provided on the instrument panel or on the steering column.

Heater, defrost, and air conditioning control panel.

Turn signal arm: A self-canceling turn signal with high beam headlight controls.

Windshield wiper control will have high, low, and intermittent modes.

Parking brake control: An air actuated push/pull park brake control.

Chassis horn control: Activation of the chassis horn control will be provided through the center of the steering wheel.

High idle engagement switch: A maintained rocker switch with integral indicator lamp will be provided. The switch will activate and deactivate the high idle function. The "OK To Engage High Idle" indicator lamp must be active for the high idle function to engage. A green indicator lamp integral to the high idle engagement switch will indicate when the high idle function is engaged. "OK To Engage High Idle" indicator lamp: A green indicator light will be provided next to the high idle activation switch to indicate that the interlocks have been met to allow high idle engagement.

Emergency switching will be controlled by multiple individual warning light switches for various groups or areas of emergency warning lights. An Emergency Master switch provided on the instrument panel that enables or disables all individual warning light switches is included.

An additional "Emergency Master" button will be provided on the lower left hand corner of the gauge panel to allow convenient control of the "Emergency Master" system from inside the driver's door when standing on the ground.

Custom Switch Panels
The design of cab instrumentation will allow for emergency lighting and other switches to be placed within easy reach of the operator thus improving safety. There will be positions for up to four (4) switch panels in the lower instrument console and up to six (6) switch panels in the overhead visor console. All switches have backlit labels for low light conditions.

Diagnostic Panel
A diagnostic panel will be provided and accessible while standing on the ground.

The panel will be located inside the driver's side door left of the steering column.

The diagnostic panel will allow diagnostic tools such as computers to connect to various vehicle systems for improved troubleshooting providing a lower cost of ownership. Diagnostic switches will allow ABS systems to provide blink codes should a problem exist.

The diagnostic panel will include the following:

ENGINE/TRANSMISSION/ABS J1939 Diagnostic Port
Bid #: 933 16 2.25
ABS Diagnostic Switch and Indicator - The switch and amber indicator will allow access to diagnostic mode and display of standard ABS system fault blink codes that may be generated by the ABS system
DPF REGEN (Diesel Particulate Filter Regeneration Switch) (where applicable) will be provided to request regeneration of the engine emission system. An amber indicator will be provided on top of the switch that will illuminate in a "CHECK ENGINE" condition
REGEN INHIBIT (Diesel Particulate Filter Regeneration Inhibit Switch) (where applicable) will be provided that will request that regeneration be temporarily prevented. A green indicator will be provided on top of the Regen Inhibit switch that will illuminate when the Regen Inhibit feature is active. Regen Inhibit will be disabled upon cycling of the ignition switch to the off state.
0002544 Air Restriction Indicator - Pierce
Chassis

AIR RESTRICTION INDICATOR
A high air restriction warning indicator light (electronic) will be provided. 0543751 Light, Do Not Move Apparatus

"DO NOT MOVE APPARATUS" INDICATOR
A flashing red indicator light, located in the driving compartment, will be illuminated automatically per the current NFPA requirements.  The light will be labeled "Do Not Move Apparatus If Light Is On."
The same circuit that activates the Do Not Move Apparatus indicator will activate a steady tone alarm when the parking brake is released.
0637359 Not Required, Door Open Indicator
w/Do Not Move Truck Light,
Enf/Saber FR
0632738 Switching, Cab Instrument Lower
Console & Overhead, Rocker,
Enforcer

SWITCH PANELS
The built-in switch panels will be located in the lower console or overhead console of the cab.

Switches will be rocker type with an indicator light, of which is an integral part of the switch. 0802940 Wiper Control, 2-Speed with
Intermittent, Saber FR/Enforcer

WIPER CONTROL
Wiper control will consist of a two (2)-speed windshield wiper control with intermittent feature and windshield washer controls. The control will be located on the left side of the center instrument panel.
0797189 Wiring, Spare, 4.8 A 12V DC, USB
Termination Blue Sea 1045 1st

SPARE CIRCUIT
There will be one (1) dual USB fast charge socket mounts installed on the apparatus.

The above wires will have the following features:

The positive wire will be connected directly to the battery power.

The negative wire will be connected to ground.

Wires will be protected to 4.8 amps at 12 volts DC.

The USB socket mount will be panel position #14.

Termination will be a Blue Sea Systems part number 1045 dual USB charger socket.

Wires will be sized to 125% of the protection.

This circuit(s) may be load managed when the parking brake is applied. 0548004 Wiring, Spare, 15 A 12V DC 1st

SPARE CIRCUIT
There will be one (1) pair of wires, including a positive and a negative, installed on the apparatus.

The above wires will have the following features:

The positive wire will be connected directly to the battery power The negative wire will be connected to ground
Wires will be protected to 15 amps at 12 volts DC
Power and ground will terminate EMS cabinet upper right corner Termination will be with a 10-place bus bar with screws and removable cover Wires will be sized to 125 percent of the protection
The circuit(s) may be load managed when the parking brake is set. 0548006 Wiring, Spare, 15 A 12V DC 2nd

SPARE CIRCUIT
There will be one (1) pair of wires, including a positive and a negative, installed on the apparatus.

The above wires will have the following features:

The positive wire will be connected directly to the battery power.

The negative wire will be connected to ground.

Wires will be protected to 15 amps at 12 volts DC.

Power and ground will terminate behind officer seat.

Termination will be with a 10-place bus bar with screws and removable cover.

Wires will be sized to 125 percent of the protection.

This circuit(s) may be load managed when the parking brake is set.

Bid #: 933 17 2.26
0743033 Bin, Center Dash Console

CENTER STORAGE BIN
A bin will be provided within reach of the officer in the center of the cab close to the windshield.

The depth and width of the bin will be maximized for the space available.

The bin is not intended for storage of loose equipment. Items stored on bin will be permanently attached to meet NFPA requirements.
0763646 Vehicle Information Center, LCD On
Gauge Cluster Only, Sab/Enf

INFORMATION CENTER
There will be a LCD display integral to the cab gauge panel provided that will display the following information:

Total distance
Trip distance
Total hours
Trip hours
PTO "A" hours
PTO "B" hours
0734854 Collision Mitigation, Not Requested

0610240 Vehicle Data Recorder w/Seat Belt
Monitor

VEHICLE DATA RECORDER
There will be a vehicle data recorder (VDR) capable of reading and storing vehicle information provided.

The information stored on the VDR can be downloaded through a USB port mounted in a convenient location determined by cab model. A USB cable can be used to connect the VDR to a laptop to retrieve required information. The program to download the information from the VDR will be available to download on-line.

The vehicle data recorder will be capable of recording the following data via hardwired and/or CAN inputs:

Vehicle Speed - MPH
Acceleration - MPH/sec
Deceleration - MPH/sec
Engine Speed - RPM
Engine Throttle Position - % of Full Throttle
ABS Event - On/Off
Seat Occupied Status - Yes/No by Position
Seat Belt Buckled Status - Yes/No by Position
Master Optical Warning Device Switch - On/Off
Time - 24 Hour Time
Date - Year/Month/Day
Seat Belt Monitoring System
A seat belt monitoring system (SBMS) will be provided. The SBMS will be capable of monitoring up to 10 seating positions indicating the status of each seat position per the following:

Seat Occupied & Buckled = Green LED indicator illuminated Seat Occupied & Unbuckled = Red LED indicator with audible alarm No Occupant & Buckled = Red LED indicator with audible alarm No Occupant & Unbuckled = No indicator and no alarm
The SBMS will include an audible alarm that will warn that an unbuckled occupant condition exists and the parking brake is released, or the transmission is not in park. 0696439 Antenna Mount, Custom Chassis,
Cable Routed to Instrument Panel
Area

RADIO ANTENNA MOUNT
There will be two (2) standard 1.125", 18 thread antenna-mounting base(s) installed one (1) on the left side and one (1) on the right side on the cab roof with high efficiency, low loss, coaxial cable(s) routed to the instrument panel area. A weatherproof cap will be installed on the mount. 0653533 Camera, Pierce, 7" LCD, Rear
Camera Only

VEHICLE CAMERA SYSTEM
There will be a color vehicle camera system provided with the following:

One (1) camera located at the rear of the apparatus, pointing rearward, displayed automatically with the vehicle in reverse.

The camera image will be displayed on a 7.00" LCD display located in view of the driver in the custom dash, per instrument panel layout. The display will include manual camera activation capability and audio from the active camera.

The following components will be included:

One (1) MO700136DC, display
One (1) SV-CW134639CAI, camera
All necessary cables
0523921 Recess, Rear Vision Camera

RECESS REAR CAMERA
A rear camera recess will be provided in the center at the rear .

Bid #: 933 18 2.27
0624241 Electrical Power/Signal Protection &
Control, Enforcer

ELECTRICAL POWER CONTROL SYSTEM
A compartment will be provided in or under the cab to house the vehicle's electrical power and signal circuit protection and control components. The power and signal protection and control compartment will contain circuit protection devices and power control devices. Power and signal protection and control components will be protected against corrosion, excessive heat, excessive vibration, physical damage and water spray.

Serviceable components will be readily accessible.

Circuit protection devices, which conform to SAE standard, will be utilized to protect each circuit.

All circuit protection devices will be sized to prevent wire and component damage when subjected to extreme current overload. General protection circuit breakers will be Type-I automatic reset (continuously resetting) and conform to SAE J553 or J258. When required, automotive type fuses conforming to SAE J554, J1284, J1888 or J2077 will be utilized to protect electronic equipment.

Power control relays and solenoids will have a direct current (dc) rating of 125 percent of the maximum current for which the circuit is protected.

Visual status indicators will be supplied to identify control safety interlocks and vehicle status. In addition to visual status indicators, audible alarms designed to provide early warning of problems before they become critical will be used.

Voltage Monitor System
A voltage monitor system will be provided to indicate the status of each battery system connected to the vehicle's electrical load. The monitor system will provide visual and audio warning when the system voltage is above or below optimum levels.

Power and Ground Studs
Spare circuits will be provided in the primary distribution center for two-way radio equipment.

The spare circuits will consist of the following:

One (1) 12-volt DC, 30 amp battery direct spare
One (1) 12-volt DC ground and un-fused switched battery stud located in or adjacent to the power distribution center
EMI/RFI Protection
The electrical system proposed will include means to control undesired electromagnetic and radio frequency emissions. State of the art electrical system design and components will be used to ensure radiated and conducted EMI (electromagnetic interference) and RFI (radio frequency interference) emissions are suppressed at their source.

The apparatus proposed will have the ability to operate in the electromagnetic environment typically found in fire ground operations. The contractor will be able to demonstrate the EMI and RFI testing has been done on similar apparatus and certifies that the vehicle proposed meets SAE J551 requirements.

EMI/RFI susceptibility will be controlled by applying immune circuit designs, shielding, twisted pair wiring and filtering. The electrical system will be designed for full compatibility with low level control signals and high powered two-way radio communication systems. Harness and cable routing will be given careful attention to minimize the potential for conducting and radiated EMIRFI susceptibility. 0624256 Electrical System, Enforcer Hard
Wired

ELECTRICAL
All 12-volt electrical equipment installed by Pierce Manufacturing will conform to modern automotive practices. All wiring will be high temperature crosslink type. Wiring will be run, in loom or conduit, where exposed and have grommets where wire passes through sheet metal.

Automatic reset circuit breakers will be provided which conform to SAE Standards. Wiring will be color, function and number coded. Function and number codes will be continuously imprinted on all wiring harness conductors at 2.00" intervals. Exterior exposed wire connectors will be positive locking, and environmentally sealed to withstand elements such as temperature extremes, moisture and automotive fluids.

Electrical wiring and equipment will be installed utilizing the following guidelines:

All holes made in the roof will be caulked with silicon. Large fender washers, liberally caulked, will be used when fastening equipment to the underside of the cab roof.

Any electrical component that is installed in an exposed area will be mounted in a manner that will not allow moisture to accumulate in it. Exposed area will be defined as any location outside of the cab or body.

Electrical components designed to be removed for maintenance will not be fastened with nuts and bolts. Metal screws will be used in mounting these devices. Also, a coil of wire will be provided behind the appliance to allow them to be pulled away from mounting area for inspection and service work.

Corrosion preventative compound will be applied to all terminal plugs located outside of the cab or body. All non-waterproof connections will have this compound in the plug to prevent corrosion and for easy separation (of the plug).

All lights that have their sockets in a weather exposed area will have corrosion preventative compound added to the socket terminal area.

All electrical terminals in exposed areas will have silicon applied completely over the metal portion of the terminal.

All lights and reflectors, required to comply with Federal Motor Vehicle Safety Standard #108, will be furnished. Rear identification lights will be recessed mounted for protection.

Lights and wiring mounted in the rear bulkheads will be protected from damage by installing a false bulkhead inside the rear compartments.

An operational test will be conducted to ensure that any equipment that is permanently attached to the electrical system is properly connected and in working order.

The results of the tests will be recorded and provided to the purchaser at time of delivery.

Bid #: 933 19 2.28
0079166 Batteries, (4) Exide Grp 31, 950 CCA
ea, Threaded Stud

BATTERY SYSTEM
There will be four (4) 12 volt Exide®, Model 31S950X5W, batteries that include the following features will be provided:
950 CCA, cold cranking amps
190 amp reserve capacity
High cycle
Group 31
Rating of 3800 CCA at 0 degrees Fahrenheit
760 minutes of reserve capacity
Threaded stainless steel studs
Each battery case will be a black polypropylene material with a vertically ribbed container for increased vibration resistance. The cover will be manifold vented with a central venting location to allow a 45 degree tilt capacity.

The inside of each battery will consist of a "maintenance free" grid construction with poly wrapped separators and a flooded epoxy bottom anchoring for maximum vibration resistance. 0008621 Battery System, Single Start, All
Custom Chassis

BATTERY SYSTEM
There will be a single starting system with an ignition switch and starter button provided and located on the cab instrument panel.

MASTER BATTERY SWITCH
There will be a master battery switch provided within the cab within easy reach of the driver to activate the battery system.

An indicator light will be provided on the instrument panel to notify the driver of the status of the battery system.
0002698 Battery Compartment,
Saber/Enforcer

BATTERY COMPARTMENTS
Batteries will be placed on non-corrosive mats and stored in well ventilated compartments located under the cab.

Heavy-duty, 2/0 gauge, color coded battery cables will be provided.  Battery terminal connections will be coated with anti-corrosion compound.

Battery solenoid terminal connections will be encapsulated with semi-permanent rubberized compound.

JUMPER STUDS
One (1) set of battery jumper studs with plastic color-coded covers will be included on the battery compartments.
0531313 Charger, Sngl Sys, IOTA, DSL 55, 55
amp, Kussmaul 091-94-12 Indicator

BATTERY CHARGER
An IOTA, Model DLS-55, 55 amp battery charger will be provided.

The battery charger will be wired to the 120-volt shoreline to activate automatically when power is connected.

There will be a Kussmaul, Model 091-94-12, remote indicator. 0662220 Location, Charger, Cab Behind Driver
Seat, Dash CF/Saber FR/Enf

Battery charger will be located in the cab behind the driver seat 0530951 Location, Bat Chrg Ind, DS Behind
Cab Door
The battery charger indicator will be located behind the driver's door on the outside of the cab. 0016857 Shoreline, 20A 120V, Kussmaul Auto
Eject, 091-55-20-120, Super

AUTO EJECT FOR SHORELINE
There will be one (1) Kussmaul™, Model 091-55-20-120, 20 amp 120 volt AC shoreline inlet(s) provided to operate the dedicated 120 volt AC circuits on the apparatus.

The shoreline inlet(s) will include red weatherproof flip up cover(s).

There will be a release solenoid wired to the vehicle's starter to eject the AC connector when the engine is starting.

The shoreline(s) will be connected to the battery charger.

There will be a mating connector body supplied with the loose equipment.

There will be a label installed near the inlet(s) that state the following:

Line Voltage
Current Ratting (amps)
Phase
Frequency
0026800 Shoreline Location

The shoreline receptacle will be located on the driver side of cab, above wheel. 0647729 Alternator, 320 amp, Delco Remy
40SI

ALTERNATOR
A Delco Remy®, Model 40SI, alternator will be provided. It will have a rated output current of 320 amps, as measured by SAE method J56. The alternator will feature an integral regulator and rectifier system that has been tested and qualified to an ambient temperature of 257 degrees Fahrenheit (125 degrees Celsius). The alternator will be connected to the power and ground distribution system with heavy-duty cables sized to carry the full rated alternator output.

Bid #: 933 20 2.29
0644176 Load Manager, Integrated In
Electrical System, Saber FR/Enforcer

ELECTRONIC LOAD MANAGEMENT
An electronic load management (ELM) system that monitors the vehicles 12-volt electrical system, and automatically reduces the electrical load in the event of a low voltage condition and by doing so, ensures the integrity of the electrical system.

The ELM will monitor the vehicle's voltage while at the scene (parking brake applied). It will sequentially shut down individual electrical loads when the system voltage drops below a preset value. Two (2) separate electrical loads will be controlled by the load manager. The ELM will sequentially re-energize electrical loads as the system voltage recovers. 0783157 Headlights, Rect LED, JW Spkr Evo
2, Heat, AXT/DCF/Enf/Imp/Sab/Vel

HEADLIGHTS
There will be four (4) JW Speaker®, Model 8800, 4" x 6" rectangular LED lights with heated lens mounted in the front quad style, chrome housing on each side of the cab grille:
the outside light on each side will contain a part number 055***1 low beam module the inside light on each side will contain a part number 055***1 high beam module the headlights to include chrome bezels
The low beam lights will be activated when the headlight switch is on.

The high beam and low beam lights will be activated when the headlight switch and the high beam switch is activated.
0802935 Light, Directional, Wln M62T* LED,
Cmn Bzl, Above Headlights, Sab/Enf

FRONT DIRECTIONALS
The front directional's will be Whelen®, Model M62T, 4.31" high x 6.75" wide x 1.37" deep directional lights with amber LEDs. The lens color(s) to be clear. The directional's will be housed in the same common bezel as the front warning light and will be located above the headlights.

The housing to be polished and the trim shall be chrome.

The flash pattern of the directional lights will be Steady On (Solid). 0620054 Light, Directional/Marker,
Intermediate, Weldon 9186-8580-29
LED 2lts

INTERMEDIATE LIGHT
There will be two (2) Weldon, Model 9186-8580-29, amber LED turn signal marker lights furnished, one (1) each side, in the rear fender panel. The light will double as a turn signal and marker light.
0647802 Lights, Clearance/Marker/ID, Front,
P25 LED 5 Lts, Saber FR/Enforcer

CAB CLEARANCE/MARKER/ID LIGHTS
There will be five (5) amber LED lights provided to indicate the presence and overall width of the vehicle in the following locations:

Three (3) amber LED identification lights will be installed in the center of the cab above the windshield.

Two (2) amber LED clearance lights will be installed, one (1) on each outboard side of the cab above the windshield.
0647899 Lights, Directional/Marker, Cab Front
Side, Weldon 9186-8580-29 LED,
Sab/Enf

FRONT CAB SIDE DIRECTIONAL/MARKER LIGHTS
There will be two (2) Weldon, Model 9186-8580-29, amber LED lights installed front of the cab door, one (1) on each side of the cab.

The lights will activate as marker lights with the headlight switch and directional lights with the corresponding directional circuit.
0627282 Lights, Clearance/Marker/ID, Rear,
FRP LED Bar & P25 LED 4Lts

REAR CLEARANCE/MARKER/ID LIGHTING
There will be a three (3) LED light bar used as identification lights located at the rear of the apparatus per the following:

As close as practical to the vertical centerline
Centers spaced not less than 6.00" or more than 12.00" apart Red in color
All at the same height
There will be two (2) LED lights installed at the rear of the apparatus used as clearance lights located at the rear of the apparatus per the following:

To indicate the overall width of the vehicle
One (1) each side of the vertical centerline
As near the top as practical
Red in color
To be visible from the rear
All at the same height
There will be two (2) LED lights installed on the side of the apparatus used as marker lights as close to the rear as practical per the following:

To indicate the overall length of the vehicle
One (1) each side of the vertical centerline
As near the top as practical
Red in color
To be visible from the side
All at the same height
There will be two (2) red reflectors located on the rear of the truck facing to the rear. One (1) each side, as far to the outside as practical, at a minimum of 15.00", but no more than 60.00", above the ground.

There will be two (2) red reflectors located on the side of the truck facing to the side. One (1) each side, as far to the rear as practical, at a minimum of 15.00", but no more than 60.00", above the ground.

Per FMVSS 108 and CMVSS 108 requirements.

Bid #: 933 21 2.30
0804519 Lights, Tail, Wln M62BTT* Red
Stop/Tail & M62T* Amber Dir Arw

REAR FMVSS LIGHTING
The rear stop/tail and directional lighting will include the following:

Two (2) Whelen®, Model M62BTT, 4.30" high x 6.70" wide x 1.40" deep brake/tail lights with red LEDs
Two (2) Whelen, Model M62T, 4.30" high x 6.70" wide x 1.40" deep directional lights with amber LEDs. The directional lights will be set to Sequence (80 FPM) to Solid flash pattern.

The lens color(s) to be the same as the LEDs.

The lights to include chrome trim.
0561471 Lights, Backup, Wln M6BUW, LED,
For Tail Lt Housing
There will be two (2) Whelen Model M6BUW, LED backup lights provided in the tail light housing. 0889577 Bracket, License Plate & Light, P25
LED, Stainless Brkt

LICENSE PLATE BRACKET
One (1) license plate bracket constructed of stainless steel will be provided at the rear of the apparatus.

One (1) white LED light with chrome housing will be provided to illuminate the license plate. A stainless steel light shield will be provided over the light that will direct illumination downward, preventing white light to the rear.
0556842 Bezels, Wln, (2) M6 Chrome Pierce,
For mtg (4) Wln M6 lights

LIGHTING BEZEL
There will be two (2) Whelen, Model M6FCV4P, four (4) place chromed ABS housings with Pierce logos provided for the rear M6 series stop/tail, directional, back up, scene lights or warning lights. 0589905 Alarm, Back-up Warning, PRECO
1040

BACK-UP ALARM
A PRECO, Model 1040, solid-state electronic audible back-up alarm that actuates when the truck is shifted into reverse will be provided. The device will sound at 60 pulses per minute and automatically adjust its volume to maintain a minimum ten (10) dBA above surrounding environmental noise levels.
0687604 Lights, Perimeter Cab, Truck-Lite
6060C LED 4Dr, Grommet Mt

CAB PERIMETER SCENE LIGHTS
There will be four (4) Truck-Lite, Model 6060C, white LED lights with grommets provided, one (1) for each cab and crew cab door.

These lights will be activated automatically when the battery switch is on and the exit doors are opened or by the same means as the body perimeter scene lights. 0617866 Lights, Perimeter Pump House,
Truck-Lite 6060C LED 2lts

PUMP HOUSE PERIMETER LIGHTS
There will be two (2) Truck-Lite, Model 6060C, white LED lights with grommets provided under the pump panel running boards, one (1) each side.

The lights will be controlled by the same means as the body perimeter lights. 0683575 Lights, Perimeter Body, Truck-Lite
6060C LED 2ts, Rear Step

BODY PERIMETER SCENE LIGHTS
There will be two (2) Truck-Lite, Model 6060C, white LED lights with grommets provided under at the rear step area of the body, one (1) each side shining to the rear.

The perimeter scene lights will be activated when the parking brake is applied. 0556360 Lights, Step, P25 LED 4lts, Pump Pnl
Sw

STEP LIGHTS
Four (4) white LED step lights will be provided. One (1) step light will be provided on each side, on the front compartment face and two (2) step lights at the rear to illuminate the tailboard.

In order to ensure exceptional illumination, each light will provide a minimum of 25 foot-candles (fc) covering an entire 15.00" x 15.00" square placed 10.00" below the light and a minimum of 1.5 fc covering an entire 30.00" x 30.00" square at the same 10.00" distance below the light.

These step lights will be actuated with the pump panel light switch.

All other steps on the apparatus will be illuminated per the current edition of NFPA 1901. 0671467 Housing, Light, Mounting Box, S/S for
Scene Light

SCENE LIGHT, MOUNTING HOUSING
There will be two (2) polished stainless steel housing(s) provided for the scene light(s).

The housing(s) will be installed one each side rear body. 0598966 Lights, Side Scene, FRC SPA900-
Q70 Surface Mt, 2nd

SCENE LIGHTS
There will be two (2) Fire Research, Model SPA900-Q70 scene light(s) with chrome flange(s) installed on the side of the apparatus, one behind passenger side crew cab door, and one above compartment RS1 between side body post's ..

A control for the light(s) selected above will be the following:
a switch at the driver's side switch panel
a switch at the pump operator's panel
no additional switch location
no additional switch location
These lights may be load managed when the parking brake is set.

Bid #: 933 22 2.31
0598967 Lights, Side Scene, FRC SPA900-
Q70 Surface Mt, 1st

SCENE LIGHTS
There will be two (2) Fire Research, Model SPA900-Q70 scene light(s) with chrome flange(s) installed on the side of the apparatus, behind driver side crew cab door, and one above compartment LS1 between side body post's ..

A control for the light(s) selected above will be the following:
a switch at the driver's side switch panel
a switch at the pump operator's panel
no additional switch location
no additional switch location
These lights may be load managed when the parking brake is set. 0776075 Light, Visor, Wln, 12V P*H1* Pioneer
LED 1st
12 VOLT LIGHTING
There will be one (1) Whelen® Model P*H1*, 8,875 lumens 12 volt DC LED light(s) with a combination of flood and spot optics provided on the front visor, centered.

The housing(s) painted parts of this light assembly to be red number 106.

The light(s) will be controlled by a switch at the driver's side switch panel.

These light(s) may be load managed when the parking brake is applied. 0532358 Not Required, Deck Lights, Other
Hose Bed & Rear Lighting

0768474 Lights, Hose Bed, Below Alum Cvr,
Amdor AY-LB-12HW040, 40" LED
4lts

LIGHTS BELOW HOSE BED COVER
There will be four (4) Amdor Model AY-LB-12HW040, 700 lumens, 40.00" white LED lights provided to illuminate the hose bed area.

Two (2) LED light strips will be installed on the driver's side hose bed cover 30.00" from the front and rear of the hose bed, as close to the hinge as practical.

Two (2) LED light strips will be installed on the passenger's side hose bed cover 30.00" from the front and rear of the hose bed, as close to the hinge as practical.

The lights will be activated when the battery switch is on, and when the hosebed cover is raised. 0645677 Lights, Not Required, Rear Work, Alt.
12 Volt Lights At Rear Body
0645611 Lights, Rear Scene, FRC, SPA900-
Q70, Surface Mt, 1st

REAR SCENE LIGHT(S)
There will be two (2) Fire Research, Model SPA900-Q70, LED scene light(s) with chrome trim bezels installed at the rear of the apparatus, upper rear bulkhead, one per side.

The light(s) will be controlled by a switch at the driver's side switch panel and by a cup switch at the driver's side rear bulkhead.

The light(s) may be load managed when the parking brake is set. 0709438 Lights, Walk Surf, FRP Flood, LED

WALKING SURFACE LIGHT
There will be Model FRP, 4" round black 12 volt DC LED floodlight(s) with bolt mount provided to illuminate the entire designated walking surface on top of the body.

The light(s) will be activated when the body step lights are on. 0060115 Pumper, Medium, Aluminum, 2nd
Gen
0554271 Body Skirt Height, 20"

Bid #: 933 23 2.32
0028245 Tank, Water, 750 Gallon, Poly, Med

WATER TANK
Booster tank will have a capacity of 750 gallons and be constructed of polypropylene plastic by United Plastic Fabricating, Incorporated.

Tank joints and seams will be nitrogen welded inside and out.

Tank will be baffled in accordance with NFPA Bulletin 1901 requirements.

Baffles will have vent openings at both the top and bottom to permit movement of air and water between compartments.

Longitudinal partitions will be constructed of .38" polypropylene plastic and will extend from the bottom of the tank through the top cover to allow for positive welding.

Transverse partitions will extend from 4.00" off the bottom of the tank to the underside of the top cover.

All partitions will interlock and will be welded to the tank bottom and sides.

Tank top will be constructed of .50" polypropylene. It will be recessed .38" and will be welded to the tank sides and the longitudinal partitions.

Tank top will be sufficiently supported to keep it rigid during fast filling conditions.

Construction will include 2.00" polypropylene dowels spaced no more than 30.00" apart and welded to the transverse partitions. Two (2) of the dowels will be drilled and tapped (.50" diameter, 13.00" deep) to accommodate lifting eyes.

A sump that will be sized dependent on the tank to pump plumbing will be provided at the bottom of the water tank.

Sump will include a drain plug and the tank outlet.

Tank will be installed in a fabricated cradle assembly constructed of structural steel.

Sufficient crossmembers will be provided to properly support bottom of tank. Crossmembers will be constructed of steel bar channel or rectangular tubing.

Tank will "float" in cradle to avoid torsional stress caused by chassis frame flexing. Rubber cushions, .50" thick x 3.00" wide, will be placed on all horizontal surfaces that the tank rests on.

Stops or other provision will be provided to prevent an empty tank from bouncing excessively while moving vehicle.

Mounting system will be approved by the tank manufacturer. 0003405 Overflow, 4.00" Water Tank, Poly

Fill tower will be constructed of .50" polypropylene and will be a minimum of 8.00" wide x 14.00" long.

Fill tower will be furnished with a .25" thick polypropylene screen and a hinged cover.

An overflow pipe, constructed of 4.00" schedule 40 polypropylene, will be installed approximately halfway down the fill tower and extend through the water tank and exit to the rear of the rear axle. 0028104 Foam Cell Required
0074425 Modified Poly Tank for Equipment
Storage Rack
0633066 Sleeve, Through Tank

SLEEVE, PLUMBING, THROUGH TANK
Two (2) sleeves will be provided in the water tank for a 3.00" pipe and a 1.50" Aeroquip hose for booster reel to the rear.
0553729 Not Required, Restraint, Water Tank,
Heavy Duty
0003429 Not Required, Direct Tank Fill

0003424 Not Required, Dump Valve

0048710 Not Required, Jet Assist

0030007 Not Required, Dump Valve Chute

0514778 Not Required, Switch, Tank Dump
Master
0126633 Hose Bed, Aluminum, Pumper

HOSE BED
The hose bed will be fabricated of .125"-5052 aluminum with a nominal 38,000 psi tensile strength.

Upper and rear edges of side panels will have a double break for rigidity.

The upper inside area of the beavertails will be covered with brushed stainless steel to prevent damage to painted surface when hose is removed.

Flooring of the hose bed will be removable aluminum grating with the top surface corrugated to aid in hose aeration. The grating slats will be a minimum of 0.50" x 4.50" with spacing between slats for hose ventilation.
0723549 Painted Hose Bed

The hose bed interior walls will be painted to match the lower body color.

Bid #: 933 24 2.33
0003481 Hose Bed Capacity, Special

Hose bed will accommodate 200' of 2.50" DJ hose, 400' of 1.50" forestry hose, 800' of 4.00" DJ hose, 200' of 1.75" DJ hose, 800' of 2.50" DJ hose.
0003488 Divider, Hose Bed, Unpainted

HOSE BED DIVIDER
Four (4) hosebed dividers will be furnished for separating hose.

Each divider will be constructed of a .125" brushed aluminum sheet fitted and fastened into a slotted, 1.50" diameter radiused extrusion along the top, bottom, and rear edge.

Divider will be fully adjustable by sliding in tracks, located at the front and rear of the hose bed.

Divider will be held in place by tightening bolts, at each end.

Acorn nuts will be installed on all bolts in the hose bed which have exposed threads. 0526260 Cross-Divider, Hose Bed, Location

A cross-divider will be provided MOUNTED TO LEAVE 120" OF FREE SPACE IN THE HOSEBED.  The divider will be bolted to the side sheet. 0730459 Cover, Hose Bed, Alum Treadplate,
Bolted T-Bar

HOSE BED COVER
A two (2) section hose bed cover, constructed of .125" bright aluminum treadplate, will be furnished. The cover will be hinged with full length stainless steel piano hinge. The sides will be slanted down with the center of the cover supported by a stationary modular bridgework support.

The cover will be reinforced so that it can support the weight of a man walking on the cover.

The cover is designed with the left cover opening first.

If access to water tank fill tower is blocked by the hose bed cover, then a hinged door will be provided in it so that tank may be filled without raising cover doors.

Chrome grab handles and gas filled cylinders will be provided to assist in opening and closing the cover. A handrail is provided at the rear, in the center of the support, to assist in opening the cover.

The hose bed cover will be connected to the Do Not Move Truck indicator. The light will be activated if the cover is not in the stowed position and the parking brake is released. 0505155 Flap, Rear of Alum Hose Bed Cover,
Two Piece, Vinyl

HOSEBED END FLAP
A pair of black vinyl flaps will be installed on the rear, one (1) for each of the aluminum treadplate hose bed covers.

Each vinyl flap will have three (3) nylon tie down straps, with quick release thumb spring buckles.

Fasnap model 207668 stainless steel buckles will be attached to the flaps. These vinyl end skirts will be installed directly to the hosebed frame.

Rubber coated hooks and stainless steel footman loops will secure the end skirts/bed covers to the main body.
0013512 Running Boards, 12.75" Deep

RUNNING BOARDS
Running boards will be fabricated of .125" bright aluminum treadplate.

Each running board will be supported by a welded 2.00" square tubing and channel assembly, which will be bolted to the pump compartment substructure.

Running boards will be 12.75" deep and spaced .50" away from the pump panel.

A splash guard will be provided above the running board treadplate. 0689621 Tailboard, 16" Deep

TAILBOARD
The tailboard will also be constructed of .125" bright aluminum treadplate and spaced .50" from the body, as well as supported by a structural steel assembly.

The tailboard area will be 16.00" deep.

The exterior side will be flanged down and in for increased rigidity of tailboard structure. 0690037 Wall, Rear, Smooth Aluminum/Body
Material

REAR WALL, SMOOTH ALUMINUM/BODY MATERIAL
The rear facing surfaces of the center rear wall will be smooth aluminum.

The bulkheads, the surface to the rear of the side body compartments, will be smooth and the same material as the body.

Any inboard facing surfaces below the height of the hosebed will be aluminum diamondplate. 0889214 Tow Eyes, w/Tow Bar, 2G Pumper

REAR TOW EYES
Two (2) tow eyes, which are an integral part of the body mounting substructure, will be installed below the rear of the truck.

The tow eyes will be of adequate strength to allow the truck to be pulled from the eyes.

REAR TOW BAR
One (1) tow bar will be installed under the tailboard, 3.00" forward from the rear of the tailboard.

With air ride suspension and a 65 gallon fuel tank, the tow bar will be located .50" further rearward than normal when there is this combination of options.

The tow bar assembly will be designed and positioned to allow up to a 30-degree upward angled pull of 17,000 lb, or a 20,000 lb straight horizontal pull in line with the centerline of the vehicle.

The tow bar design will have been tested and evaluated using finite element analysis techniques. 0590926 Hose Restraint, Running Board,
Velcro Straps

RUNNING BOARD HOSE RESTRAINT
A pair of 2.00" wide black nylon straps with Velcro fasteners will be provided for each hose tray to secure the hose during travel. There will be One (1) hose tray located in the right side running board.

Bid #: 933 25 2.34
0014112 Tray, Hose, Running Board, Special
Capacity, Predefined

HOSE TRAY
Two (2) hose trays will be recessed one (1) in each side running board.

Capacity of the tray will be 25' of 5.00" hose.

Rubber matting will be installed on the floor of the tray to provide proper ventilation. Drain holes will be provided.
0895820 Construction, Compt, Alum, 2G
Pumper

COMPARTMENTATION
Body and compartments will be fabricated of 0.125", 5052-H32 aluminum.

Side compartments will be an integral assembly with the rear fenders.

Circular fender liners will be provided for prevention of rust pockets and ease of maintenance.

Side compartment flooring will be of the sweep out design with the floor higher than the compartment door lip.

The side compartment door opening will be framed by flanging the edges in 1.75" and bending out again 0.75" to form an angle.

Drip protection will be provided above the doors by means of bright aluminum extrusion, formed bright aluminum treadplate or polished stainless steel.

The top of the compartment will be covered with bright aluminum treadplate rolled over the edges on the front, rear and outward side. These covers will have the corners welded.

Side compartment covers will be separate from the compartment tops.

Front facing compartment walls will be covered with bright aluminum treadplate.

All screws and bolts which protrude into a compartment will have acorn nuts on the ends to prevent injury.

UNDERBODY SUPPORT SYSTEM
Due to the severe loading requirements of this pumper a method of body and compartment support suitable for the intended load will be provided.

The backbone of the support system will be the chassis frame rails which is the strongest component of the chassis and is designed for sustaining maximum loads.

Forward to the rear axle, the support system will include "L"-shaped support members bolted to the chassis frame rails. These welded support members will include vertical formed channels, horizontal structural channels, and support gussets. These parts extend from the chassis frame outward underneath the body.

Rearward to the rear axle, the body support system will include two rearward facing "L"-shaped support members bolted to the chassis frame rails. These support members will be connected to the two body supporting crossmembers forming a boxed foundation for the rear body support system.

Steel upper platform decks will be mounted on the top of these support members to create a floating substructure which will result in a 500 lb equipment support rating per lower compartment.

All structural components of this system will be made from high strength 50K steel plate material or structural steel componentry. The steel frames as well as the steel vertical angles will be treated with an epoxy E-coat to provide resistance to corrosion and chemicals as standard.

The floating substructure will be separated from the horizontal members with neoprene elastomer isolators. These isolators will reduce the natural flex stress of the chassis from being transmitted to the body.

Isolators will have a broad load range, proven viability in vehicular applications, be of a fail-safe design and allow for all necessary movement in three (3) transitional and rotational modes.

The neoprene isolators will be installed in a pattern which assimilates a three (3)-point mounting pattern to reduce the natural flex of the chassis being transmitted to the body.

A design with body compartments hanging on the chassis in an unsupported fashion will not be acceptable.

AGGRESSIVE WALKING SURFACE
All exterior surfaces designated as stepping, standing, and walking areas will comply with the required average slip resistance of the current NFPA standards.

LOUVERS
Louvers will be stamped into compartment walls to provide the proper airflow inside the body compartments and to prevent water from dripping into the compartment. Where these louvers are provided, they will be formed into the metal and not added to the compartment as a separate plate.

TESTING OF BODY DESIGN
Body structural analysis will be fully tested. Proven engineering and test techniques such as finite element analysis, strain gauging, and model analysis will be performed with special attention given to fatigue, life and structural integrity of the body and substructure.

Body will be tested while loaded to its greatest in-service weight.

The criteria used during the testing procedure will include:

Raising opposite corners of the vehicle tires 9.00" to simulate the twisting a truck may experience when driving over a curb.

Making a 90 degree turn, while driving at 20 mph to simulate aggressive driving conditions.

Driving the vehicle at 35 mph on a washboard road.

Driving the vehicle at 55 mph on a smooth road.

Accelerating the vehicle fully, until reaching the approximate speed of 45 mph on rough pavement.

Evidence of actual testing techniques will be made available upon request.

Bid #: 933 26 2.35
0023650 LS 152" Rollup, Full Height Front &
Rear, FDLER

LEFT SIDE COMPARTMENTATION
The left side compartmentation will consist of three rollup door compartments.

A full height, rollup door compartment ahead of the rear wheels will be provided. The interior dimensions of this compartment will be 34.50" wide x 66.63" high x 25.88" deep in the lower

25.00" of the compartment and 12.00" deep in the remaining upper portion. The clear door opening will be a minimum of 28.75" wide x 56.88" high.

A rollup door compartment over the rear wheels will be provided. The interior dimensions of this compartment will be 66.50" wide x 32.88" high x 12.00" deep. The clear door opening will be a minimum of 58.25" wide x 23.13" high.

A full height, rollup door compartment behind the rear wheels will be provided.The interior dimensions of this compartment will be 47.75" wide x 67.63" high x 25.88" deep in the lower 26.00" of height and 12.00" deep in the remaining upper section of the compartment.

The clear door opening will be a minimum of 44.75" wide x 57.88" high.

The interior height of the compartments will be measured from the compartment floor to the ceiling. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartments will be measured from the back wall to the inside of the door frame.

Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.
0063658 RS 152" Rollup, Full Height Front &
Rear, FDLER

RIGHT SIDE COMPARTMENTATION
The right side compartmentation will consist of three rollup door compartments.

A full height, rollup door compartment ahead of the rear wheels will be provided. The interior dimensions of this compartment will be 34.50" wide x 66.63" high x 25.88" deep in the lower

25.00" of the compartment and 12.00" deep in the remaining upper portion. The clear door opening will be a minimum of 28.75" wide x 56.88" high.

A rollup door compartment over the rear wheels will be provided. The interior dimensions of this compartment will be 66.50" wide x 32.88" high x 12.00" deep. The clear door opening will be a minimum of 58.25" wide x 23.13" high.

A full height, rollup door compartment behind the rear wheels will be provided.The interior dimensions of this compartment will be 47.75" wide x 67.63" high x 25.88" deep in the lower 26.00" of height and 12.00" deep in the remaining upper section of the compartment.

The clear door opening will be a minimum of 44.75" wide x 57.88" high.

The interior height of the compartments will be measured from the compartment floor to the ceiling. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartments will be measured from the back wall to the inside of the door frame.

Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.
0594005 Doors, Rollup, Amdor, Side
Compartments

SIDE COMPARTMENT ROLLUP DOOR(S)
There will be six (6) compartment doors installed on the side compartments, double faced, aluminum construction, painted one (1) color to match the lower portion of the body and manufactured by AMDOR™ brand rollup doors.

Door(s) will be constructed using 1.00" extruded double wall aluminum slats which will feature a flat smooth interior surface to provide maximum protection against equipment hang-up. The slats will be connected with a structural driven ball and socket hinge designed to provide maximum curtain diaphragm strength. Mounting and adjusting the curtain will be done with a clip system that connects the curtain to the balancer drum allowing for easy tension adjustment without tools.

The slats will be mounted in reusable slat shoes with positive snap-lock securement.

Each slat will incorporate weather tight recessed dual durometer seals. One (1) fin will be designed to locate the seal within the extrusion. The second will serve as a wiping seal which will also allow for compression to prevent water ingression.

The doors will be mounted in a one (1)-piece aluminum side frame with recessed side seals to minimize seal damage during equipment deployment. All seals including side frames, top gutters and bottom panel are to be manufactured utilizing non-marring materials.

Bottom panel flange of rollup door will be equipped with two (2) cut-outs to allow for easier access with gloved hands.

A polished stainless steel lift bar to be provided for each roll-up door. The lift bar will be located at the bottom of door with striker latches installed at the base of the side frames. Side frame mounted door strikers will include support beneath the stainless steel lift bar to prevent door curtain bounce, improve bottom seal life expectancy and to avoid false door ajar signals.

All injection molded rollup door wear components will be constructed of Type 6 nylon.

Each rollup door will have a 3.00 inch diameter balancer/tensioner drum to assist in lifting the door.

The header for the rollup door assembly will not exceed 4.00".

A heavy-duty magnetic switch will be used for control of open compartment door warning lights. 0083701 Compt, Rear, Rollup, 44.50" FF,

25.88" D

REAR COMPARTMENTATION
A roll-up door compartment above the rear tailboard will be provided.

The interior dimensions of this compartment will be 40.00" wide x 47.38" high x 25.88" deep. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartment will be calculated with the compartment door closed.

A louvered, removable access panel will be furnished on the back wall of the compartment.

The rear compartment will be open into the rear side compartments.

The clear door opening of this compartment will be a minimum of 33.25" wide x 37.63" high.

Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.

Bid #: 933 27 2.36
0594003 Door, Amdor, Rollup, Rear
Compartment

ROLLUP REAR COMPARTMENT DOOR
The rear compartment will have a rollup door.

The door will be double faced, aluminum construction, satin aluminum and manufactured by AMDOR™ brand rollup doors.

The door will be constructed using 1.00" extruded double wall aluminum slats which will feature a flat smooth interior surface to provide maximum protection against equipment hang-up. The slats will be connected with a structural driven ball and socket hinge designed to provide maximum curtain diaphragm strength. Mounting and adjusting the curtain will be done with a clip system that connects the curtain to the balancer drum allowing for easy tension adjustment without tools.

The slats will be mounted in reusable slat shoes with positive snap-lock securement.

Each slat will incorporate weather tight recessed dual durometer seals. One (1) fin will be designed to locate the seal within the extrusion. The second will serve as a wiping seal which will also allow for compression to prevent water ingression.

The door will be mounted in a one (1)-piece aluminum side frame with recessed side seals to minimize seal damage during equipment deployment. All seals including side frames, top gutters and bottom panel are to be manufactured utilizing non-marring materials.

Bottom panel flange of rollup door will be equipped with two (2) cut-outs to allow for easier access with gloved hands.

A polished stainless steel lift bar to be provided for each roll-up door. The lift bar will be located at the bottom of door with striker latches installed at the base of the side frames. Side frame mounted door strikers will include support beneath the stainless steel lift bar to prevent door curtain bounce, improve bottom seal life expectancy and to avoid false door ajar signals.

All injection molded rollup door wear components will be constructed of Type 6 Nylon.

The door will have a 3.00 inch diameter balancer/tensioner drum to assist in lifting the door.

The header for the rollup door assembly will not exceed 4.00".

A heavy-duty magnetic switch will be used for control of open compartment door warning lights. 0554995 No Body Modification Required

0019845 Guard, Drip Pan, S/S, Rollup Door

DOOR GUARD
There will be seven (7) compartment doors that will include a guard/drip pan designed to protect the roll-up door from damage when in the retracted position and contain any water spray.  The guard will be fabricated from stainless steel and installed all body compartments.. 0616670 Lights, Compt, Pierce LED, Dual
Light Strips, Each Side of Door,
Pumper/Tanker

COMPARTMENT LIGHTING
There will be seven (7) compartment(s) with two (2) white 12 volt DC LED compartment light strips. The dual light strips will be centered vertically along each side of the door framing. There will be two (2) light strips per compartment. The dual light strips will be in all body compartment (s).

Any remaining compartments without light strips will have a 6.00" diameter Truck-Lite, Model:
79384 light. Each light will have a number 1076 one filament, two wire bulb.

Opening the compartment door will automatically turn the compartment lighting on. 0687146 Shelf Tracks, Painted

MOUNTING TRACKS
There will be seven (7) sets of tracks for mounting shelf(s) in LS1, LS2, LS3, RS1, RS2, RS3 and B1. These tracks will be installed vertically to support the adjustable shelf(s). The tracks will be painted to match the compartment interior.
0600350 Shelves, Adj, 500 lb Capacity, Full
Width/Depth, Predefined Locations

ADJUSTABLE SHELVES
There will be eight (8) shelves with a capacity of 500 lb provided.

The shelf construction will consist of .188" aluminum painted spatter gray with 2.00" sides.

Each shelf will be infinitely adjustable by means of a threaded fastener, which slides in a track.

The shelves will be held in place by .12" thick stamped plated brackets and bolts.

The location(s) will be in LS1 at the depth transition point, in RS1 at the transition point, in RS3 at the transition point to the right of partition, in RS2 centered between the floor and the ceiling, in RS3 in the upper third to the right of the partition, in LS2 centered between the floor and ceiling, in B1 centered between the floor and ceiling and in LS3 at the depth transition point. 0647091 Tray, Floor Mounted, Slide-Out,
500lb, 2.00" Sides

SLIDE-OUT FLOOR MOUNTED TRAY
There will be two (2) floor mounted slide-out tray(s) provided.

Each tray will have 2.00" high sides and a minimum capacity rating of 500 lb in the extended position.

Each tray will be constructed of aluminum painted spatter gray There will be two undermount-roller bearing type slides rated at 250lb each provided. The pair of slides will have a safety factor rating of 2.

To ensure years of dependable service, the slides will be coated with a finish that is tested to withstand a minimum of 1,000 hours of salt spray per ASTM B117.

To ensure years of easy operation, the slides will require no more than a 50lb force for push-in or pull-out movement when fully loaded after having been subjected to a 40 hour vibration (shaker) test under full load. The vibration drive file will have been generated from accelerometer data collected from a heavy truck chassis driven over rough gravel roads in an unloaded condition.

Proof of compliance will be provided upon request.

Automatic locks will be provided for both the "in" and "out" positions. The trip mechanism for the locks will be located at the front of the tray for ease of use with a gloved hand.

The location(s) will be RS1 and LS1.

Bid #: 933 28 2.37
0721316 Partition, Vertical Compt, Special
Location

VERTICAL COMPARTMENT PARTITION
one (1) vertical partition(s) will be provided in the RS3 compartment CENTERED ON THE

UPPER INNER (TANK) WALL, HEIGHT TO BE FROM THE CEILING TO THE TOP OF THE SHELF AT THE TRANSITION POINT.

The partition construction will consist of body material painted spatter gray. 0024016 Rub Rail, Aluminum Extruded, Side &
Rear of Body

RUB RAIL
Bottom edge of the side and rear of the body compartments will be trimmed with a bright aluminum extruded rub rail.

Trim will be 2.12" high with 1.38" flanges turned outward for rigidity.

The rub rails will not be an integral part of the body construction, which allows replacement in the event of damage.
0784811 Fender Crowns, Rear, Stainless,
w/Removable Liner

BODY FENDER CROWNS
Polished stainless steel fender crowns will be provided around the rear wheel openings with a dielectric barrier will be provided between the fender crown and the fender sheet metal to prevent corrosion.

The fender crowns will be held in place with stainless steel screws that thread directly into a composite nut and not directly into the parent body sheet metal to eliminate dissimilar metals contact and greatly reduce the chance for corrosion. Rubber welting will be provided between the body and crown.

BODY FENDER LINER
A painted to match the lower body color fender liner will be provided. The liners will be removable to aid in the maintenance of rear suspension components. 0519849 Not Required, Hose, Hard Suction

HARD SUCTION HOSE
Hard suction hose will not be required.
0612961 Trough, HSH, (2), Side Sheet Mount,
Angle Bracket

HOSE TROUGH
Two (2) hard suction hose troughs will be side sheet mounted on an adjustable angle bracket.

There will be one (1) sets of hose troughs located on the left side.

Troughs will be constructed of aluminum painted job color.

A quantity of two (2) chrome plated, quarter turn, spring loaded clamps will be provided on the troughs to contain the hard suction hose.
0626229 Handrails, Side Pump Panels, Per
Print

HANDRAILS
The handrails will be 1.25" diameter knurled aluminum to provide a positive gripping surface.

Chrome plated end stanchions will support the handrail. Plastic gaskets will be used between end stanchions and any painted surfaces.

Drain holes will be provided in the bottom of all vertically mounted handrails.

Handrails will be provided to meet NFPA 1901 section 15.8 requirements. The handrails will be installed as noted on the sales drawing.
0004126 Handrails, Beavertail, Standard

HANDRAILS
One (1) vertical handrail will be located on each rear beavertail. 0004146 Handrail, Rear, Below Hose Bed, Full
Width

HANDRAIL
One (1) full width horizontal handrail will be provided below the hose bed at the rear of the apparatus.
0004154 Handrail, Extra - 10" Long

ADDITIONAL HANDRAIL
Two (2) handrails, 10.00" long, will be mounted one each side, on top of the front hosebed sheet.. 0622393 Compt, Air Pack Fender Panel

AIR PACK STORAGE
A total of two (2) air pack compartment(s) will be provided and located RS FWD, RS REAR. The air pack compartment(s) will be tapered to match the profile of the space available in the fender.

The compartment(s) will be approximately 15.50" wide at the top and 5.00" wide at the bottom for the wheel cutout. The compartment(s) will be 15.50" tall at the body side compartment and 6.00" tall at the wheel cutout. The compartment(s) will be 26.00" deep and have a drain hole.

Inside the compartment, black Dura-Surf friction reducing material glued to the floor will be provided.

A painted stainless steel hinged door with a Southco raised trigger C2 chrome lever latch will be provided to contain the air pack. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body sheet metal.

Bid #: 933 29 2.38
0648325 Compt, Air Bottle, Double, Tri Door,
Fender Panel
AIR BOTTLE STORAGE (Double)
A quantity of two (2) air bottle compartments, 15.25" wide x 7.75" tall x 26.00" deep, will be provided on the left side forward of the rear wheels. The triangular door shall cover the double air bottle opening and the DEF tank access. and on the left side rearward of the rear wheels. The triangular door shall cover the double air bottle opening and the fuel tank access.. A painted stainless steel door with a Southco raised trigger C2 chrome lever latch will be provided to contain the air bottle. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body sheet metal.

Inside the compartment, black rubber matting will be provided.

AIR BOTTLE COMPARTMENT STRAP
A strap will be provided in the air bottle compartment to help contain the air bottle when the vehicle is parked on an incline. The strap will wrap around the neck and attach to the wall of the compartment.
0004225 Ladder, 24' Duo-Safety 900A 2-
Section

EXTENSION LADDER
There will be a 24' two-section aluminum Duo-Safety Series 900-A extension ladder provided. 0004230 Ladder, 14' Duo-Safety 775A Roof ROOF LADDER
There will be a 14' aluminum Duo-Safety Series 775-A roof ladder provided. 0049958 Ladders Btwn Tank & S.Sht, RS,
Ext'd Rr, Encl'd Complete, RPH

LADDER STORAGE
The ladders will be stored between the water tank and the right side compartments.

The ladders will extend into the pump compartment just to the rear of the water pump discharges.

The ladder storage area will be enclosed as practical by means of sheet metal to protect the ladders from road dirt. The ladders that extend into the pump house will also be enclosed. A black rubber boot will be provided to enclose the ladders in the gap between the pump house and the body.

Each ladder will be stored vertically in a separate stainless steel storage trough. Each stainless steel trough will be lined with Dura-Surf nylon slides.

An aluminum enclosure will be provided at the rear of the body to properly contain the ladders.

This enclosure will extend to the rear of the side body compartments.

The enclosure will also include a vertically hinged smooth aluminum door with a D-handle latch to access the ladders. The door will be hinged on the left side.

On the rear wall, there will be a bright aluminum treadplate scuffplate around the door for the ladder enclosure.
0733387 Ladder, 10' Duo-Safety Folding 585A

FOLDING LADDER
One (1) 10.00' aluminum, Series 585-A, Duo-Safety folding ladder will be installed. 0733796 Trough, Folding Ladder, Ladder
Storage Btwn Tank & S.Sht

FOLDING LADDER STORAGE
There will be storage designated right side for folding ladders stored between the side sheet in a stainless steel trough in the ladder storage compartment. 0892606 SP Compt w/Door, Stokes Basket
Storage, Top of 4-Way Hose Bed
Cover

STOKES BASKET COMPARTMENT
A stokes basket compartment will be mounted to the top of the bright aluminum treadplate hose bed cover on the left side. The compartment will be fabricated of bright aluminum treadplate and will have a bright aluminum treadplate lift-up door at the rear. The compartment(s) will be sized for a stokes basket 84.00" long x 25.00" wide x 9.00" high. 0789534 Pike Pole, 8' DUO Safety, Fiberglass

PIKE POLE, 8'
One (1) pike pole, 8' long Duo Safety with a fiberglass handle, will be provided. 0733370 Pike Pole, 6' DUO Safety, Fiberglass

PIKE POLE, 6'
One (1) pike pole, 6' long Duo Safety with a fiberglass handle, will be provided. 0004361 Tubes, Alum, Pike Pole Storage

PIKE POLE STORAGE
Aluminum tubing will be used for the storage of two (2) pike poles and will be located in ladder storage compartment. If the head of a pike pole can come in contact with a painted surface, a stainless steel scuffplate will be provided.
0785102 Steps, Folding, Front of Body, Cargo
Bed Access, w/LED, Trident

FOLDING STEPS FRONT OF BODY
Folding steps will be provided full height on the left side and right side body compartments to provide access to the cargo bed. Steps will be spaced evenly on the sales drawing. Actual quantity may vary due to pump panel interferences but will meet the NFPA required maximum stepping height.

The Trident steps will be bright finished, non-skid with a black tread coating on the stepping surface.

The step will incorporate an LED light to illuminate the stepping surface.

The steps can be used as a hand hold with two openings wide enough for a gloved hand.

Bid #: 933 30 2.39
0592994 Steps, Folding, Rear of Body, w/LED,
Trident

REAR FOLDING STEPS
Bright finished, non-skid folding steps with a black tread coating on the stepping surface will be provided at the rear. Each step will incorporate an LED light to illuminate the stepping surface.

The steps can be used as a hand hold with two openings wide enough for a gloved hand. 0007590 Pump House, Side Control, 52",
Control Zone

PUMP COMPARTMENT
The pump compartment will be separate from the hose body and compartments so that each may flex independently of the other. It will be a fabricated assembly made of the same material as the rear body using tubing, angles and channels which supports both the fire pump and the side running boards.

The pump compartment will be mounted on the chassis frame rails with rubber biscuits in a four point pattern to allow for chassis frame twist.

Pump compartment, pump, plumbing and gauge panels will be removable from the chassis in a single assembly.

PUMP MOUNTING
Pump will be mounted to a substructure which will be mounted to the chassis frame rail using rubber isolators. The mounting will allow chassis frame rails to flex independently without damage to the fire pump.

LEFT SIDE PUMP CONTROL PANELS
All pump controls and gauges will be located at the left side of the apparatus and properly identified.

Layout of the pump control panel will be ergonomically efficient and systematically organized.

The pump operator's control panel will be removable in two (2) main sections for ease of maintenance:

The upper section will contain sub panels for the mounting of the pump pressure control device, engine monitoring gauges, electrical switches, and foam controls (if applicable). Sub panels will be removable from the face of the pump panel for ease of maintenance. Below the sub panels will be located all valve controls and line pressure gauges.

The lower section of the panel will contain all inlets, outlets, and drains.

All push/pull valve controls will have 1/4 turn locking control rods with polished chrome plated zinc tee handles. Guides for the push/pull control rods will be chrome plated zinc castings securely mounted to the pump panel. Push/pull valve controls will be capable of locking in any position.

The control rods will pull straight out of the panel and will be equipped with universal joints to eliminate binding.

IDENTIFICATION TAGS
The identification tag for each valve control will be recessed in the face of the tee handle.

All discharge outlets will have color coded identification tags, with each discharge having its own unique color. Color coding will include the labeling of the outlet and the drain for each corresponding discharge.

All line pressure gauges will be mounted directly above the corresponding discharge control tee handles and recessed within the same chrome plated casting as the rod guide for quick identification. The gauge and rod guide casting will be removable from the face of the pump panel for ease of maintenance. The casting will be color coded to correspond with the discharge identification tag.

All remaining identification tags will be mounted on the pump panel in chrome plated bezels.

The pump panel on the right side will be removable with lift and turn type fasteners.

Trim rings will be installed around all inlets and outlets. 0037731 Pump House Structure, Raised,
Included with Ladder Storage

0004425 Pump, Waterous, CSU, 1500 GPM,
Single Stage
PUMP
Pump will be a Waterous CSU, 1500 gpm single (1) stage midship mounted centrifugal type.

Pump will be the class "A" type.

Pump will deliver the percentage of rated discharge at pressures indicated below:
- 100% of rated capacity at 150 psi net pump pressure.
- 70% of rated capacity at 200 psi net pump pressure.
- 50% of rated capacity at 250 psi net pump pressure.

Pump body will be close-grained gray iron, bronze fitted, and horizontally split in two (2) sections for easy removal of the entire impeller shaft assembly (including wear rings).

Pump will be designed for complete servicing from the bottom of the truck, without disturbing the pump setting or apparatus piping.

Pump case halves will be bolted together on a single horizontal face to minimize chance of leakage and facilitate ease of reassembly. No end flanges will be used.

Discharge manifold of the pump will be cast as an integral part of the pump body assembly and will provide a minimum of three (3) 3.50" openings for flexibility in providing various discharge outlets for maximum efficiency.

The three (3) 3.50" openings will be located as follows: one (1) outlet to the right of the pump, one (1) outlet to the left of the pump, and one (1) outlet directly on top of the discharge manifold.

Impeller shaft will be stainless steel, accurately ground to size. It will be supported at each end by sealed, anti-friction ball bearings for rigid precise support. Impeller will have flame plated hubs assuring maximum pump life and efficiency despite any presence of abrasive matter in the water supply.

Bearings will be protected from water and sediment by suitable stuffing boxes, flinger rings, and oil seals. No special or sleeve type bearings will be used.

Bid #: 933 31 2.40
0004481 Seal, Grafoil, Waterous

PUMP PACKING
Stuffing boxes will be of the conventional two (2) piece, split-gland type, to permit adjustment or replacement of Grafoil packing without disturbing the pump. Water will be fed into stuffing box lantern rings for proper lubrication and cooling when the pump is operating.

Lantern rings will be located at the inner ends of the stuffing boxes, to avoid having to remove them when replacing pump packing.

Wear rings will be bronze and easily replaceable to restore original pump efficiency and eliminate the need to replace the entire pump casing due to wear. 0559769 Trans, Pump, Waterous C20 Series

PUMP TRANSMISSION
The pump transmission will be made of a three (3) piece, aluminum, horizontally split casing.

Power transfer to pump will be through a high strength Morse HY-VO silent drive chain. By the use of a chain rather than gears, 50% of the sprocket will be accepting or transmitting torque, compared to two (2) or three (3) teeth doing all the work.

Drive shafts will be 2.35" diameter hardened and ground alloy steel and supported by ball bearings. The case will be designed to eliminate the need for water cooling. 0635600 Pumping Mode, Stationary Only

PUMPING MODE
An interlock system will be provided to ensure that the pump drive system components are properly engaged so that the apparatus can be safely operated. The interlock system will be designed to allow stationary pumping only.
0605126 Pump Shift, Air Mnl Override, Split
Shaft, Interlocked, Waterous

AIR PUMP SHIFT
Pump shift engagement will be made by a two (2) position sliding collar, actuated pneumatically (by air pressure), with a three (3) position air control switch located in the cab. A manual back-up shift control will also be located on the left side pump panel.

Two (2) indicator lights will be provided adjacent to the pump shift inside the cab. One (1) green light will indicate the pump shift has been completed and be labeled "pump engaged". The second green light will indicate when the pump has been engaged, and that the chassis transmission is in pump gear. This indicator light will be labeled "OK to pump".

The pump shift will be interlocked to prevent the pump from being shifted out of gear when the chassis transmission is in gear to meet NFPA requirements.

The pump shift control in the cab will be illuminated to meet NFPA requirements. 0003148 Transmission Lock-up, EVS TRANSMISSION LOCK-UP
The direct gear transmission lock-up for the fire pump operation will engage automatically when the pump shift control in the cab is activated.
0004547 Auxiliary Cooling System

AUXILIARY COOLING SYSTEM
A supplementary heat exchange cooling system will be provided to allow the use of water from the discharge side of the pump for cooling the engine water. The heat exchanger will be a separate unit. It will be installed in the pump or engine compartment with the control located on the pump operator's control panel. The exchanger will be plumbed to the master drain valve. 0014486 Not Required, Transfer Valve, Single
Stage Pump
0777650 Valve, Relief Intake, Akron

INTAKE RELIEF VALVE - PUMP
An Akron Style 53 relief valve will be installed on the suction side of the pump preset at 125 psig.

The relief valve will have a working range of 50 psi to 250 psi.

The outlet will terminate below the frame rails with a 2.50" National Standard hose thread adapter and will have a "do not cap" warning tag.

The relief valve pressure control will be located behind the right side pump panel with a stainless steel access door .
0794959 Controller, Pressure, Pierce, Pump
Boss, PBA300

PRESSURE CONTROLLER
A Pierce Pump Boss Model PBA300 pressure governor will be provided.

A pressure transducer will be installed in the water discharge manifold on the pump.

The display panel will be located at the pump operator's panel. 0072153 Primer, Trident, Air Prime, Air
Operated

PRIMING PUMP
The priming pump will be a Trident Emergency Products compressed air powered, high efficiency, multistage venturi based AirPrime System, conforming to standards outlined in the current edition of NFPA 1901.

All wetted metallic parts of the priming system are to be of brass and stainless steel construction.

One (1) priming control will open the priming valve and start the pump primer. 0044552 Line, 0.50" Recirculating w/Check
Valve

RECIRCULATING LINE WITH CHECK VALVE
A 0.50" diameter recirculating line, from the pump to the water tank, will be furnished with a control installed at the pump operator's control panel. A check valve will be provided in this line to prevent the back flow of water from the tank to the pump if the valve is left in the open position.

Bid #: 933 32 2.41
0780364 Manuals, Pump, (2) Total, Electronic
Copies

PUMP MANUALS
There will be a total of two (2) pump manuals provided by the pump manufacturer and furnished with the apparatus. The manuals will be provided by the pump manufacturer in the form of two (2) electronic copies. Each manual will cover pump operation, maintenance, and parts. 0602512 Plumbing, Stainless Steel and Hose,
Single Stage Pump, Control Zone

PLUMBING, STAINLESS STEEL AND HOSE
All inlet and outlet lines will be plumbed with either stainless steel pipe, flexible polypropylene tubing or synthetic rubber hose reinforced with hi-tensile polyester braid. All hose's will be equipped with brass or stainless steel couplings. All stainless steel hard plumbing will be a minimum of a schedule 10 wall thickness.

Where vibration or chassis flexing may damage or loosen piping or where a coupling is required for servicing, the piping will be equipped with victaulic or rubber couplings.

Plumbing manifold bodies will be ductile cast iron or stainless steel.

All piping lines are to be drained through a master drain valve or will be equipped with individual drain valves. All drain lines will be extended with a hose to drain below the chassis frame.

All water carrying gauge lines will be of flexible polypropylene tubing.

All piping, hose and fittings will have a minimum of a 500 PSI hydrodynamic pressure rating. 0795135 Plumbing, Stainless Steel, w/Foam
System

FOAM SYSTEM PLUMBING
All piping that is in contact with the foam concentrate or foam/water solution will be stainless steel. The fittings will be stainless steel or brass. Cast iron pump manifolds will be allowed. 0004645 Inlets, 6.00" - 1250 GPM or Larger
Pump

MAIN PUMP INLETS
A 6.00" pump manifold inlet will be provided on each side of the vehicle. The suction inlets will include removable die cast zinc screens that are designed to provide cathodic protection for the pump, thus reducing corrosion in the pump.
0004646 Cap, Main Pump Inlet, Long Handle,

NST, VLH

MAIN PUMP INLET CAP
The main pump inlets will have National Standard Threads with a long handle chrome cap.

The cap will be the Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0084610 Valves, Akron 8000 series- All

VALVES
All ball valves will be Akron® Brass. The Akron valves will be the 8000 series heavy-duty style with a stainless steel ball and a simple two-seat design. No lubrication or regular maintenance is required on the valve.

Valves will have a ten (10) year warranty.
0016158 Valve, Inlet(s) Recessed, Side Cntrl,
"Control Zone"
The location of the valve for the one (1) inlet will be recessed behind the pump panel. 0004700 Control, Inlet, at Valve

INLET CONTROL
The side auxiliary inlet(s) will incorporate a quarter-turn ball valve with the control located at the inlet valve. The valve operating mechanism will indicate the position of the valve. 0004660 Inlet (1), Left Side, 2.50"

LEFT SIDE INLET
There will be one (1) auxiliary inlet with a 2.50" valve at the left side pump panel, terminating with a 2.50" (F) National Standard hose thread adapter.

The auxiliary inlet will be provided with a strainer, chrome swivel and plug. 0029147 Not Required, Inlet, Right Side

0092569 No Rear Inlet (Large Dia) Requested

0064116 No Rear Inlet Actuation Required

0092696 Not Required, Cap, Rear Inlet

0009648 No Rear Intake Relief Valve Required
on Rear Inlet
0586174 Provision, Front Inlet

FRONT INLET PROVISION
Provisions for a front inlet will be provided on the right side pump suction manifold. Flange will be capped off for possible addition of front inlet at a later date.

Bid #: 933 33 2.42
0092568 No Rear Auxiliary Inlet Requested

0723049 Valve, .75" Bleeder, Aux. Side Inlet,
"T" Swing Handle

INLET BLEEDER VALVE
A 0.75" bleeder valve will be provided for each side gated inlet.

The valves will be located behind the panel with a "T" swing style handle control extended to the outside of the panel.

The handles will be chrome plated and provide a visual indication of valve position. The swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage.

The water discharged by the bleeders will be routed below the chassis frame rails. 0014751 Tank to Pump, (1) 3.00" Valve, 3.00"
Plumbing, Reverse Linkage

TANK TO PUMP
The booster tank will be connected to the intake side of the pump with heavy duty piping and a quarter turn 3.00" full flow line valve with the control remotely located at the operator's panel. The tank to pump line will run straight (no elbows) from the pump into the front face of the water tank and down into the tank sump. A rubber coupling will be included in this line to prevent damage from vibration or chassis flexing.

The control on the pump panel will be "in" when the valve is open and "out" when the valve is closed.

A check valve will be provided in the tank to pump supply line to prevent the possibility of "back filling" the water tank.
0004905 Outlet, Tank Fill, 1.50"

TANK REFILL
A 1.50" combination tank refill and pump re-circulation line will be provided, using a quarter-turn full flow ball valve controlled from the pump operator's panel. 0062133 Control, Outlets, Manual, Pierce HW
if applicable

DISCHARGE OUTLET CONTROLS
The discharge outlets will incorporate a quarter-turn ball valve with the control located at the pump operator's panel. The valve operating mechanism will indicate the position of the valve.

If a handwheel control valve is used, the control will be a minimum of a 3.9" diameter stainless steel handwheel with a dial position indicator built in to the center of the handwheel.

Any 3.00 inch or larger discharge valve will be a slow-operating valve in accordance with NFPA

16.7.5.3. 0004940 Outlet, Left Side, 2.50"

LEFT SIDE DISCHARGE OUTLETS
There will be One (1) discharge outlet with a 2.50" valve on the left side of the apparatus, terminating with a 2.50" (M) National Standard hose thread adapter. 0005091 Elbow, Left Side Outlets, 45 Degree,

2.50" FNST x 2.50" MNST, VLH

LEFT SIDE OUTLET ELBOWS
The 2.50" discharge outlets located on the left side pump panel will be furnished with a 2.50" (F) National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45 degree elbow.

The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0092570 Not Required, Outlets, Left Side
Additional
0035094 Not Required, Elbow, Left Side
Outlets, Additional
0004945 Outlet, Right Side, 2.50"

RIGHT SIDE DISCHARGE OUTLETS
There will be One (1) discharge outlet with a 2.50" valve on the right side of the apparatus, terminating with a 2.50" (M) National Standard hose thread adapter. 0025091 Elbow, Right Side Outlets, 45
Degree, 2.50" FNST x 2.50" MNST,
VLH

RIGHT SIDE OUTLET ELBOWS
The 2.50" discharge outlets located on the right side pump panel will be furnished with a 2.50" (F) National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45 degree elbow.

The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0550252 Outlet, Right Side, 4" w/3" Plumbing,
Handwheel Control, (added)
There will be a 4.00" discharge outlet with a 3.00" valve with a 3.00" ball, installed on the right side of the apparatus, terminating with a 4.00" (M) National Standard hose thread adapter. This discharge outlet will be actuated with a handwheel control with position indicator at the pump operator's control panel.
0659072 Elbow, Right Side Outlets, 30
Degree, 4.00" FNST x 5.00" Storz,
Additional

ADDITIONAL RIGHT SIDE OUTLET ELBOWS
The 4.00" outlet will be furnished with a 4.00" (F) National Standard hose thread x 5.00" Storz elbow adapter with Storz cap.

Bid #: 933 34 2.43
0029137 Not Required, Outlet, Large Diameter

0007308 Not Required, Elbow, Large Diameter
Outlet
0649939 Outlet, Front, 1.50" w/2" Plumbing

FRONT DISCHARGE OUTLET
There will be one (1) 1.50" discharge outlet piped to the front of the apparatus and located on the top of the left side of the front bumper.

Plumbing will consist of 2.00" piping and flexible hose with a 2.00" ball valve with control at the pump operator's panel. A fabricated weldment made of stainless steel pipe will be used in the plumbing where appropriate. The piping will terminate with a 1.50" NST with 90 degree stainless steel swivel.

There will be automatic drains provided at all low points of the piping. 0004995 Outlet, Rear, 2.50"

REAR DISCHARGE OUTLET
There will be One (1) discharge outlet piped to the rear of the hose bed, left side, installed so proper clearance is provided for spanner wrenches or adapters. Plumbing will consist of 2.50" piping along with a 2.50" full flow ball valve with the control from the pump operator's panel. 0045091 Elbow, Rear Outlets, 45 Degree,

2.50" FNST x 2.50" MNST, VLH

REAR OUTLET ELBOWS
The 2.50" discharge outlets located at the rear of the apparatus will be furnished with a 2.50" (F) National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45 degree elbow.

The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0092574 Not Required, Outlet, Rear,
Additional
0085695 Not Required, Elbow, Rear Outlets,
Large, Additional
0004990 Outlet, Front HB, 2.50" w/2.50"
Plumbing

FRONT OF HOSE BED DISCHARGE OUTLET
There will be One (1) discharge outlet discharge(s) piped to the front of the hose bed and located LEFT SIDE BAY #1. Plumbing will consist of 2.50" piping with a 2.50" full-flow ball valve controlled at the pump operator's panel. The discharge(s) will terminate with a 2.50" (M) National Standard hose thread adapter.
0752096 Caps/Plugs for 1.00" to 3.00"
Discharges/Inlets, Vinyl Covered
Cable

DISCHARGECAPS/ INLET PLUGS
Chrome plated, rocker lug, caps with vinyl covered cables will be furnished for all discharge outlets 1.00" thru 3.00" in size, besides the pre-connected hose outlets.

Chrome plated, rocker lug, plugs with vinyl covered cables will be furnished for all auxiliary inlets

1.00" thru 3.00" in size.

The caps and plugs will incorporate a thread design to automatically relieve stored pressure in the line when disconnected.
0723042 Valve, 0.75" Bleeder, Discharges, "T"
Swing Handle

OUTLET BLEEDER VALVE
A 0.75" bleeder valve will be provided for each outlet 1.50" or larger. Automatic drain valves are acceptable with some outlets if deemed appropriate with the application.

The valves will be located behind the panel with a T swing style handle control extended to the outside of the side pump panel.

The handles will be chrome plated and provide a visual indication of valve position.

The T swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage.

Bleeders will be located at the bottom of the pump panel. They will be properly labeled identifying the discharge they are plumbed in to.

The water discharged by the bleeders will be routed below the chassis frame rails. 0015065 Outlet, 3.00" Deluge Riser w/3.50"
Waterous Valve, HW

DELUGE RISER
A 3.00" deluge riser will be installed above the pump in such a manner that a monitor can be mounted and used effectively. The piping will be 3.00" and a 3.50" Waterous valve will be installed. Piping will be installed securely so no movement develops when the line is charged.

The riser will be gated and controlled at the pump operator's panel with a Waterous chrome plated handwheel and 7 LED indicator.
0770359 No Monitor Requested,
Customer/Dealer Furnished and
Installed

MONITOR
A customer/dealer supplied and installed make and model no monitor called out monitor will be properly installed on the deluge riser.

Bid #: 933 35 2.44
0029304 No Nozzle Req'd

0005072 Deluge Mount, 3" ANSI 4 Bolt Flange

The deluge riser will have a 3.00" four (4)-bolt flange for mounting the monitor. 0723726 Speedlay Module Not Required

0722432 Hose Restraint Not Required, No
Speedlay Module
0723395 Speedlays, Not Required

0723394 Speedlays, Not Required

0029167 Crosslays Sngl Sheet Unpainted,
(2+) 1.50", Std. Cap

CROSSLAY HOSE BEDS
Two (2) crosslays with 1.50" outlets will be provided. Each bed to be capable of carrying 200' of

1.75" double jacketed hose and will be plumbed with 2.00" i.d. pipe and gated with a 2.00" quarter turn ball valve.

Outlets to be equipped with a 1.50" National Standard hose thread 90 degree swivel located in the hose bed so that hose may be removed from either side of apparatus.

The crosslay controls will be at the pump operator's panel.

The center crosslay dividers will be fabricated of 0.25" aluminum and will provide adjustment from side to side. The divider will be unpainted with a brushed finish.

Vertical scuffplates constructed of stainless steel will be provided at the front and rear ends of the bed on each side of vehicle.

Crosslay bed flooring will consist of removable perforated brushed aluminum. 0029196 Not Required, 2.50" Crosslay

0591138 Hose Restraint, Crosslay/Deadlay,
Vinyl, Strap Fasteners, Each Side,
Ends

CROSSLAY/DEADLAY HOSE RESTRAINT
There will be black vinyl end flap provided across each end of two (2) crosslay/deadlay opening (s) to secure the hose during travel. Each vinyl end flap will be permanently attached at the bottom of the crosslay/deadlay opening(s). 1.00" web straps will loop through footman loops at the opposite end of the permanently attached vinyl. They will be attached with 1.00" cam buckle fasteners.
0029260 Not Required, Speedlays

0750536 Hose Restr, Spdly, Not Required, No
Spdly
0615255 Cover, Crosslay, 3/16" Alum
Treadplate, Front Hinge

CROSSLAY COVER
A hinged .19" aluminum treadplate cover will be installed over the crosslay hose beds. It will include a latch at each end of the cover to hold it securely in place, a chrome grab handle at each end for opening and closing the cover and a foam rubber gasket where the cover comes into contact to a painted surface.

The cover will be provided with rubber latch hold open device.

The hinge will be to the front of the hose beds.
0019853 Crosslays, 8.00" Lower Than
Standard - Control Zone w/9.00"
Raised PH
CROSSLAY 8.00" LOWER THAN STANDARD
The crosslays will be lowered 8.00" from standard.
0015216 Reel, Booster, Aluminum - Over
Pump, Right Side

BOOSTER HOSE REEL
A Hannay electric rewind booster hose reel will be installed over the pump in a recessed open compartment on the right side of the apparatus. The reel will be fabricated of aluminum and have highly polished end discs.

A polished stainless steel roller and guide assembly will be mounted on the reel side of the apparatus.

Discharge control will be provided at the pump operator's panel. Plumbing to the reel will consist of 1.50" Aeroquip hose and a 1.50" valve.
0011060 Switch, Reel Rewind - One at Pump
Panel
Reel motor will be protected from overload with a circuit breaker rated to match the motor.

An electric rewind control switch will be installed on the reel side pump panel.

Bid #: 933 36 2.45
0075300 Hose, Booster - 100' of 1.00"/800 PSI

Booster hose, 1.00" diameter and 100 feet, with chrome plated Barway, or equal couplings will be provided.

Working pressure of the booster hose will be a minimum of 800 psi. 0025244 Capacity, Hose Reel 100' of 1"

Capacity of the hose reel will be 100 feet of 1.00" booster hose. 0692346 Nozzle, Elkhart Chief 4000-03, 1.00"
w/Pistol Grip
An Elkhart, model 4000-03, booster hose nozzle with pistol grip will be provided. 0021954 Cutout for Reel Access, One, w/ S/S
Trim

HOSEREEL ACCESS
A cutout will be provided in the side sheet next to the booster hose reel. This cutout will allow access to the hose and provide a window to view the reel. Stainless steel trim will be mounted horizontally and vertically around the cutout.
0014047 Linkage, Reverse, Hose Reel

The control on the pump panel will be "in" when the valve is open and "out" when the valve is closed. This style control will be provided on one (1) hose reel(s). 0622237 Roller Assembly, Additional There will be one (1) additional polished stainless steel roller and guide assembly mounted LS PUMP HOUSE TOP.

Bid #: 933 37 2.46
0624939 Foam Sys, Husky 3, Single Agent,
Multi Select Feature
HUSKY 3 FOAM PROPORTIONER
A Pierce Husky® 3 foam proportioning system will be provided. The Husky 3 is an on demand, automatic proportioning, single point, direct injection system suitable for all types of Class A and B foam concentrates, including the high viscosity (6000 cps), alcohol resistant Class B foams.

Operation will be based on direct measurement of water flow, and remain consistent within the specified flows and pressures. The system will automatically proportion foam solution at rates from .1 percent to 3 percent regardless of variations in water pressure and flow, up to the maximum rated capacity of the foam concentrate pump.

The design of the system will allow operation from draft, hydrant, or relay operation.

System Capacity
The system will have the ability to deliver the following minimum foam solution flow rates at accuracies that meet or exceed NFPA requirements at a pump rating of 150 psi. 100 gpm @ 3 percent
300 gpm @ 1 percent
600 gpm @ 0.5 percent
Class A foam setting in .1 percent increments from .1 percent to 1 percent. Typical settings of 1 percent, .5 percent and .3 percent (maximum capacity will be limited to the plumbing and water pump capacity).

Control System
The system will be equipped with a digital electronic control display located on the pump operators panel. Push button controls will be integrated into the panel to turn the system on/off, control the foam percentage, and to set the operation modes.

The percent of injection will have a preset. This preset can be changed at the fire department as desired. The percent of injection will be able to be easily changed at the scene to adjust to changing demands.

Three (3) .50 tall LEDs will display the foam percentage in numeric characters. Three (3) indicator LEDs will also be included, one (1) green, one (1) red, and one (1) yellow. The LEDs will indicate various system operation or error states.

The indications will be:

Solid Green - System On
Solid Red - Valve Position Error
Solid Yellow - Priming System
Flashing Green - Injecting Foam
Flashing Red - Low Tank Level
Flashing Yellow - Refilling Tank
The control display will house a microprocessor, which receives input from the systems water flow meter while also monitoring the position of the foam concentrate pump. The microprocessor will compare the values of the water flow versus the position/rate of the foam pump, to ensure the proportion rate is accurate. One (1) check valve will be installed in the plumbing to prevent foam from contaminating the water pump.

Hydraulic Drive System
The foam concentrate pump will be powered by an electric over hydraulic drive system. The hydraulic system and motor will be integrated into one (1) unit.

Foam Concentrate Pump
The foam concentrate pump will be of positive displacement, self-priming; linear actuated design, driven by the hydraulic system. The pump will be constructed of brass body; chrome plated stainless steel shaft, with a stainless steel piston. In order to increase longevity of the pump, no aluminum will be present in its construction.

A relief system will be provided which is designed to protect the drive system components and prevent over pressuring the foam concentrate pump
The foam concentrate pump will have minimum capacity for 3 gpm with all types of foam concentrates with a viscosity at or below 6000 cps including protein, fluoroprotein, AFFF, FFFP, or AR-AFFF. The system will deliver only the amount of foam concentrate flow required, without recirculating foam back to the storage tank. Recirculating foam concentrate back to the storage tank can cause agitation and premature foaming of the concentrate, which can result in system failure. The foam concentrate pump will be self-priming and have the ability to draw foam concentrate from external supplies such as drums or pails.

External Foam Concentrate Connection
An external foam pick-up will be provided to enable use of a foam agent that is not stored on the vehicle. The external foam pick-up will be designed to allow continued operation after the onboard foam tank is empty, or the use of foam different than the foam in the foam tank.

Panel Mounted External Pick-Up Connection / Valve
A bronze three (3)-way valve will be provided. The unit will be mounted to the pump panel. The valve unit will function as the foam system tank to pump valve and external suction valve. The external foam pick-up will be one (1) 0.75" male connection GHT (garden hose thread) with a cap.

Pick-Up Hose
A 0.75" flexible hose with an end for insertion into foam containers will be provided. The hose will be supplied with a 0.75" female swivel GHT (garden hose thread) swivel connector. The hose will be shipped loose.

Discharges
The foam system will be plumbed to the left side of front bumper, left rear outlet, front crosslay and rear crosslay.

System Electrical Load
The maximum current draw of the electric motor and system will be no more than 55 amperes at 12 VDC.
0012126 Not Required, CAF Compressor

Bid #: 933 38 2.47
0592527 Refill, Foam Tank, Integral, Husky 3

SINGLE FOAM TANK REFILL
The foam system's proportioning pump will be used to fill the foam tank. This will allow use of the auxiliary foam pick-up to pump the foam from pails or a drum on the ground into the foam tank. A foam shut-off switch will be installed in the fill dome of the tank to shut the system down when the tank is full. The fill operation will be controlled by a mode in the foam system controller. While the proportioner pump is filling the tank, the controller will display a flashing yellow LED to indicate that the tank is filling. When the tank is full, as determined by the float switch in the tank dome, the pump will stop and the controller will shut the yellow LED off. If it attempted to use tank fill and the refill valve and suction valve are in the wrong position(s), then a red LED will illuminate to indicate the improper valve position(s). When the valves are positioned properly, then filling will commence.
0031896 Demonstration, Foam System, Dealer
Provided
0005446 Foam Cell, 20 Gallon, Not Reduce
Water

FOAM TANK
The foam tank will be an integral portion of the polypropylene water tank. The cell will have a capacity of 20 gallons of foam with the intended use of Class A foam. The foam cell will not reduce the capacity of the water tank. The foam cell will have a screen in the fill dome and a breather in the lid.
0697589 Drain, 1.00", Foam Tank #1, Husky 3
Foam System, Quarter Turn

FOAM TANK DRAIN
The foam tank drain will be a 1.00" quarter turn drain valve located inside the pump/plumbing compartment.
0091079 Not Required, Foam Tank #2

0091112 Not Required, Foam Tank #2 Drain

0738072 Approval Dwg, Pump Panel(s), Not
Required
0032479 Pump Panel Configuration, Control
Zone

PUMP PANEL CONFIGURATION
The pump panel configuration will be arranged and installed in an organized manner that will provide user-friendly operation.
0629252 Material, Pump Panels, Side Control
Black Vinyl

PUMP AND GAUGE PANEL
The pump and gauge panels will be constructed of aluminum with a black vinyl finish. A polished aluminum trim molding will be provided around each panel. 0721765 Panel, Pump Access - Right Side
Only, Side Control

PUMP ACCESS
Right Side Panel
The right side upper pump panel will be removable.

Panel Fastener
The removable panels will be secured with black swell latch .

The left side pump panels will be attached with screws.

The right side lower pump panel (drain bank) will be attached with screws. 0005945 Light, Pump Compt

PUMP COMPARTMENT LIGHT
A pump compartment light will be provided inside the right side pump enclosure and accessible through a door on the pump panel.

A .125" weep hole will be provided in each light lens, preventing moisture retention. 0586382 Gauges, Engine, Included With
Pressure Controller
Engine monitoring graduated LED indicators will be incorporated with the pressure controller.

Also provided at the pump panel will be the following:
- Master Pump Drain Control
0005601 Throttle, Engine, Incl'd w/Press
Controller
0739224 Indicator Light @ Pump Panel,
Throttle Ready, Incl w/Pressure
Gov/Throttle,Green

THROTTLE READY GREEN INDICATOR LIGHT
There will be a green indicator light integrated with the pressure governor and/or engine throttle installed on the pump operators panel that is activated when the pump is in throttle ready mode. 0549333 Indicators, Engine, Included with
Pressure Controller
Bid #: 933 39 2.48
0745568 Indicator Light, Pump Panel, Ok To
Pump, Green

OK TO PUMP INDICATOR LIGHT
There will be a green indicator light installed on the pump operators panel that is activated when the pump is in Ok To Pump mode.
0511078 Gauges, 4.00" Master, Class 1, 30"-0
-600psi

VACUUM AND PRESSURE GAUGES
The pump vacuum and pressure gauges will be liquid filled and manufactured by Class 1 Incorporated ©.

The gauges will be a minimum of 4.00" in diameter and will have white faces with black lettering, with a pressure range of 30.00"-0-600#.

Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded retaining nut.

The pump pressure and vacuum gauges will be installed adjacent to each other at the pump operator's control panel.

Test port connections will be provided at the pump operator's panel. One will be connected to the intake side of the pump, and the other to the discharge manifold of the pump. They will have 0.25 in. standard pipe thread connections and non-corrosive polished stainless steel or brass plugs.

They will be marked with a label.

This gauge will include a 10 year warranty against leakage, pointer defect, and defective bourdon tube.
0511100 Gauge, 2.00" Pressure, Class 1, 30"-
0-400psi

PRESSURE GAUGES
The individual "line" pressure gauges for the discharges will be Class 1© interlube filled.

They will be a minimum of 2.00" in diameter and have white faces with black lettering.

Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded retaining nut.

Gauges will have a pressure range of 30"-0-400#.

The individual pressure gauge will be installed as close to the outlet control as practical.

This gauge will include a 10 year warranty against leakage, pointer defect, and defective bourdon tube.
0062586 Gauge, Water Level, Class 1, Pierce
Std

WATER LEVEL GAUGE
There will be an electronic water level gauge provided on the operator's panel that registers water level by means of five (5) colored LED lights. The lights will be durable, ultra-bright five (5) LED design viewable through 180 degrees. The water level indicators will be as follows:
100 percent = Green
75 percent = Yellow
50 percent = Yellow
25 percent = Yellow
Refill = Red
The light will flash when the level drops below the given level indicator to provide an eighth of a tank indication. To further alert the pump operator, the lights will flash sequentially when the water tank is empty.

The level measurement will be based on the sensing of head pressure of the fluid in the tank.

The display will be constructed of a solid plastic material with a chrome plated die cast bezel to reduce vibrations that can cause broken wires and loose electronic components. The encapsulated design will provide complete protection from water and environmental elements. An industrial pressure transducer will be mounted to the outside of the tank. The field calibratable display measures head pressure to accurately show the tank level. 0084763 Gauge, Ernst Sight Water Level,
w/Red Ball, IATS

WATER LEVEL GAUGE, ADDITIONAL
An additional water level gauge will be provided. An Ernst sight tube water level indicator with a floating red ball will be mounted on the gauge panel with an unrestricted view for the operator. 0604354 Gauge, Foam Level, FRC, Tank
Vision Pro, WLA 360-A00, Class "A"

CLASS "A" FOAM LEVEL GAUGE
A Fire Research TankVision Pro model WLA360-A00 cell/tank level indicator kit will be installed on the pump operators panel. The kit will include an electronic indicator module, a pressure sensor, a 10' sensor cable and a tank vent. The indicator will show the volume of Class "A" foam concentrate in the cell/tank on nine (9) easy to see super bright RGB LEDs. A wide view lens over the LEDs will provide for a viewing angle of 180 degrees. The indicator case will be waterproof, manufactured of Polycarbonate/Nylon material and have a distinctive green label.

The program features will be accessed from the front of the indicator module. The program will support self-diagnostics capabilities, self-calibration, six (6) programmable colored light patterns to display cell/tank volume, adjustable brightness control levels and a data link to connect remote indicators. Low foam level warnings will include flashing LEDs at 1/4 cell/tank and down chasing LEDs when the cell/tank is almost empty.

The indicator will receive an input signal from an electronic pressure sensor. The sensor will be mounted from the outside of the foam cell/tank near the bottom. No probe will be placed on the interior of the cell/tank. Wiring will be weather resistant and have automotive type plug-in connectors.

Bid #: 933 40 2.49
0593161 Light Shield, S/S LED

LIGHT SHIELD
There will be a polished, 16 gauge stainless steel light shield installed over the pump operator's panel.

There will be 12 volt DC white LED lights installed under the stainless steel light shield to illuminate the controls, switches, essential instructions, gauges, and instruments necessary for the operation of the apparatus. These lights will be activated by the pump panel light switch.

Additional lights will be included every 18.00" depending on the size of the pump house.

One (1) pump panel light will come on when the pump is in ok to pump mode.

There will be a light activated above the pump panel light switch when the parking brake is set.

This is to afford the operator some illumination when first approaching the control panel. 0606694 Air Horns, (2) Hadley, 6" Round,
eTone, In Bumper

AIR HORN SYSTEM
Two (2) Hadley®, eTone, chrome air horns will be recessed in the front bumper. The air horn system will be piped to the air brake system wet tank utilizing 0.38" tubing. A pressure protection valve will be installed to prevent the loss of air in the brake system. 0606834 Location, Air Horns, Bumper, Each
Side, Outside Frame, Inboard (Pos
#2 & #6)
Air Horn Location
The air horns will be located on each side of the bumper, just outside of the frame rails. 0757092 Control, Air Horn, Multi Select

Air Horn Control
The air horn(s) will be activated by the following:
0757077 Control, Air Horn, Lanyard, LS

Left side lanyard. The lanyard to be a plastic coated braided cable. 0757080 Control, Air Horn, Ft Sw, RS

Right side foot switch
0757084 Control, Air Horn, Horn Ring

Steering wheel horn ring with electric/air horn selector switch 0688049 Siren, Federal EQ2B-200, 200 Watt

ELECTRONIC SIREN
There will be a Federal, Model EQ2B-200, electronic siren with noise canceling microphone provided.

This siren to be active when the battery switch is on and that emergency master switch is on. 0790527 Location, Electronic Siren, Center
Dash Switch Panel, Saber FR

The electronic siren head will be located in switch panel # 8 area of the center dash switch panel. 0076156 Control, Elec Siren, Head Only The electronic siren will be controlled on the siren head only. No horn button or foot switches will be provided.
0550171 Speaker, (1) Federal, BP200-Q

SPEAKER
A 200 watt speaker will be provided. A chrome-plated "Q" grille will be installed in front of the speaker.
0601555 Location, Speaker, Frt Bumper,
Recessed, Left Side, Outside
Frame,Outbrd (Pos 7)
The speaker will be recessed in the left side of the front bumper, towards the outside. 0895310 Siren, Federal Q2B

AUXILIARY MECHANICAL SIREN
There will be a Federal Signal Model Q2B mechanical siren furnished and installed in the front of the apparatus.

The Q2B will be chrome finish.

The siren will have a 2-gauge cable connected to a power solenoid that is connected by a 2- gauge cable ran battery direct to the primary chassis batteries and will be labeled Q2B+ at the battery. The power solenoid will only be enabled when the emergency master switch is on.

The siren will have a 2-gauge ground wire connected to the chassis battery stud. The cable will be labeled Q2B- at the battery.

When the chassis battery switch is on, and the emergency master switch is on, the Q2B siren will be activated by the following:
0006097 Location of Siren, Recessed in
Bumper
The mechanical siren will be recessed in the front bumper in the center. The siren will be properly supported using the bumper framework.
0748305 Control, Mech Siren, Multi Select

MECHANICAL SIREN CONTROL
The mechanical siren will be activated by the following:

Bid #: 933 41 2.50
0748281 Control Mech Siren, Ft Sw RS

Right side foot switch.
0748282 Control Mech Siren, Ft Sw LS

Left side foot switch.
0740391 Sw, Siren Brake, Momentary Chrome
Push Button, RS
A momentary chrome push button switch will be included in the right side dash panel to activate the siren brake.
0736691 Sw, Siren Brake, Momentary Chrome
Push Button, LS
A momentary chrome push button switch will be included in the left side dash panel to activate the siren brake.
0032018 Bracket, Wedge Style, Foot Switches BRACKET, FOOT SWITCHES A wedge style bracket will be provided on the driver and officer's side of cab floor.

Each bracket will be large enough to hold the foot switches picked in this order, in the following location:
one (1) footswitch on the driver side and two (2) footswitches on the officer side, 0734625 Control, Warning Lt Intensity, Wln,
Photocell, Prk Brk

SWITCH FOR WARNING LIGHTS INTENSITY
When parking brake is set, and a Whelen®, Model LCPHOTO photocell installed on the interior forward cab dash as near to the windshield as practical, is activated due to diminished ambient light, the designated Whelen® warning lights on the cab and the warning lights on the body will transition to a low power intensity.

In order for the activation of low power mode of the warning lights, the dash mounted Whelen® photocell must sense diminished ambient light (approx. 50 LUX), the battery switch, the ignition switch, the emergency master switch, must be on, and the parking brake set.

The low power intensity mode will be reset when any of the above conditions are not met. 0740422 SP Lightbar, Wln, Freedom IV-Q, 72",
RRWRRR____RRRWRR, Lw Int

FRONT ZONE UPPER WARNING LIGHTS
There will be one (1) 72.00" Whelen Freedom IV LED lightbar mounted on the cab roof.

The lightbar will include the following:

One (1) red flashing LED module in the driver's side end position.

One (1) red flashing LED module in the driver's side front corner position.

One (1) white flashing LED module in the driver's side first front position.

One (1) red flashing LED module in the driver's side second front position.

One (1) red flashing LED module in the driver's side third front position.

One (1) red flashing LED module in the driver's side fourth front position.

Open in the driver's side fifth front position.

Open in the driver's side sixth front position.

Open in the passenger's side sixth front position.

Open in the passenger's side fifth front position.

One (1) red flashing LED module in the passenger's side fourth front position.

One (1) red flashing LED module in the passenger's side third front position.

One (1) red flashing LED module in the passenger's side second front position.

One (1) white flashing LED module in the passenger's side first front position.

One (1) red flashing LED module in the passenger's side front corner position.

One (1) red flashing LED module in the passenger's side end position.

There will be clear lenses included on the lightbar.

The light bar will have the low intensity mode wires connected to the controlling circuit.

There will be a switch in the cab on the switch panel to control this lightbar.

The white LEDs will be disabled when the parking brake is applied.

The six (6) red flashing LED modules in the front positions may be load managed when the parking brake is applied.
0745392 Lights, Front Zone, Wln M6** LED, in
Common Bzl, Lw Int

FRONT ZONE LOWER LIGHTS
There will be two (2) Whelen, Model M6**, flashing LED lights installed on the cab face above the headlights, in a common bezel with the directional lights.

The driver's side front warning light to include red LEDs The passenger's side front warning light to include red LEDs The color of the lenses will be clear
There will be a switch located in the cab on the switch panel to control the lights.

Each light will have the low intensity mode wire connected to the controlling circuit. 0746527 SP Flash Pattern, Wln M6**, Front Zone
Lower, Inside Steady Burn

FRONT ZONE LOWER WARNING FLASH PATTERN ADJUSTMENT
The flash pattern of the two (2) Whelen M6** light(s) located in the inside positions BOTH INSIDE LIGHTS will be adjusted to Steady, pattern number 159.
0063971 Daytime Running Lights, Headlights,
AXT/Saber/Enforcer (Low Beam)

DAYTIME RUNNING LIGHTS (HEADLIGHTS)
The headlights will include a feature for daytime running lights which will be automatically activated when the parking brake is released. The daytime running light feature will be deactivated when the primary headlight switch is turned on, when other headlight options are activated or when the parking brake is set. The running lights will be wired through the low beam head lights.

Bid #: 933 42 2.51
0653937 Flasher, Headlight Alternating

HEADLIGHT FLASHER
The high beam headlights will flash alternately between the left and right side.

There will be a switch installed in the cab on the switch panel to control the high beam flash. This switch will be live when the battery switch and the emergency master switches are on.

The flashing will automatically cancel when the hi-beam headlight switch is activated or when the parking brake is set.
0740512 Lights, Side Zone Lower, Wln M6**,
M6**, M6**, 6lts, Lw Int

SIDE ZONE LOWER LIGHTING LOW INTENSITY
There will be six (6) Whelen®, Model M6**, 4.31" high x 6.75" long x 1.37" deep flashing LED warning lights with chrome trim installed per the following:

Two (2) lights located, one (1) each side on the bumper extension. The driver's side, side front light to include red warning LEDs and the passenger's side, side front light to include red warning LEDs.

Two (2) lights located, one (1) each side above the front wheels. The driver's side, side middle light to include red warning LEDs and the passenger's side, side middle light to include red warning LEDs.

Two (2) lights located, one (1) each side above rear wheels. The driver's side, side rear light to include red warning LEDs and the passenger's side, side rear light to include red warning LEDs .

The warning light lens color(s) to be clear.

There will be a switch in the cab on the switch panel to control the lights.

Each light will have the low intensity mode wire connected to the controlling circuit.

Any flashing white lights will be disabled when the parking brake is set. 0746422 Lights, Rear Zn Lwr, Wln M6*, Lw Int

REAR ZONE LOWER LIGHTING
There will be two (2) Whelen®, Model M6* LED flashing warning lights with chrome trim located at the rear of the apparatus.

The driver's side rear light to be red
The passenger's side rear light to be red
The lens color(s) to be clear.

There will be a switch located in the cab on the switch panel to control the lights.

The light(s) will have the low intensity mode wire connected to the controlling circuit. 0803250 SP Light, Rear Zone Up, Wln L31H*FN
Beacon, Red LED, DVI High

REAR/SIDE ZONE UPPER WARNING LIGHTS
There will be two (2) Whelen®, Model L31H*FN, LED warning beacons provided at the rear of the truck, located one (1) each side.

The LEDs color of the lights will be red with both domes clear.

There will be a switch located in the cab on the switch panel that controls the beacons when the emergency master and battery switch are on.

The violet wire of each beacon will be connected to the low intensity control. When the low intensity control is activated, the beacons will go into DVI SingleFlash 75 Hi Intensity pattern. 0006551 Not Required, Lights, Rear Upper
Zone Blocking
0006615 Mtg, Rear Warn Lts, On Top of
Compt
The rear warning lights will be mounted on top of the compartmentation with all wiring totally enclosed. The rear deck lights will be mounted on the beavertails as high as possible. 0791528 Light, Traffic Directing, Wln TAL65,

36.00" Long, TACTL5

TRAFFIC DIRECTING LIGHT
There will be one (1) Whelen®, Model TAL65, 36.00" long x 2.87" high x 2.25" deep, amber LED traffic directing light installed at the rear of the apparatus.

The Whelen, Model TACTL5, control head will be included with this installation.

The controller will be energized when the battery switch is on.

The auxiliary flash not activated.
0551728 Location, Traf Dir Lt, Recessed with
S/S Trim
This traffic directing light will be recessed with a stainless steel trim plate at the rear of the apparatus as high as practical.
0530282 Location, Traf Dir Lt Controller,
Overhead Switch Panel DS Right
End
The traffic directing light control head will be located in the driver side overhead switch panel in the right panel position.
0768415 SP Light Twr, W-B Chf NS1.8-2 WHL, 2-
P*H2 12VDC Lts Cld 6'

LIGHT TOWER
There will be one (1) Will-Burt, Model NS1.8-2 WHL, light tower provided.

There will be two (2) Whelen, Model P*H2, 17,750 lumens 12 volt DC light heads with flood optics included on this tower.

The painted parts of the light tower and the light heads to be white.

This tower will be connected to the Do Not Move Truck Indicator in the cab.

The lights included on this tower may be load managed when the parking brake is applied. 0664472 Location, Light Tower, Crew Cab
Roof
Light Tower Location
The light tower will be installed on the crew cab roof.

Bid #: 933 43 2.52
0617750 Controller, Lt Twr, W-B, Wired
Hndhld, E-STOP Chf, Chf Pr, Pow Pr

Light Tower Controller
There will be one (1) handheld wired controller included. 0664791 Location, Light Tower Controller,
Driver's Side Front Body
Compartment
Light Tower Controller Location
The light tower controller will be installed in the driver's side front body compartment. 0781579 Receptacle, 15/20A 120V 3-Pr 3-Wr,
NEMA 5-20R SB Dup, 1st, Interior
Cab
120 VOLT RECEPTACLE
There will be one (1), 15/20 amp 120 volt AC three (3) wire straight blade duplex receptacle(s) with interior stainless steel wall plate(s), installed EMS cabinet, upper right corner next to the 12V bass bar. The NEMA configuration for the receptacle(s) will be 5-20R.

The receptacle(s) will be powered from the shoreline inlet.

There will be a label installed near the receptacle(s) that state the following:

Line Voltage
Current Ratting (amps)
Phase
Frequency
0779700 Receptacle, 15/20A 120V 3-Pr 3-Wr
SB Dup, GFI, Interior Body

120 VOLT RECEPTACLE
There will be one (1), 15/20 amp 120 volt AC three (3) wire straight blade duplex GFCI receptacle (s) with interior stainless steel wall plate(s), installed CENTER BACK WALL OF THE LOWER (DEEP) SECTION OF RS3. The NEMA configuration for the receptacle(s) will be 5-20R.

The receptacle(s) will be powered from the shoreline inlet.

There will be a label installed near the receptacle(s) that state the following:

Line Voltage
Current Ratting (amps)
Phase
Frequency
0519934 Not Required, Brand, Hydraulic Tool
System
0649753 Not Required, PTO Driven Hydraulic
Tool System
0649736 Not Required, Hydraulic Tools

0007150 Bag of Nuts and Bolts

LOOSE EQUIPMENT
The following equipment will be furnished with the completed unit:

One (1) bag of chrome, stainless steel, or cadmium plated screws, nuts, bolts and washers, as used in the construction of the unit.

Bid #: 933 44 2.53
0602516 NFPA Required Loose Equipment,
Pumper, NFPA 2016, Provided by
Fire Department

NFPA REQUIRED LOOSE EQUIPMENT PROVIDED BY FIRE DEPARTMENT The following loose equipment as outlined in NFPA 1901, 2016 edition, section 5.9.3 and 5.9.4 will be provided by the fire department.
800 ft (60 m) of 2.50" (65 mm) or larger fire hose.
400 ft (120 m) of 1.50" (38 mm), 1.75" (45 mm), or 2.00" (52 mm) fire hose.

One (1) handline nozzle, 200 gpm (750 L/min) minimum.

Two (2) handline nozzles, 95 gpm (360 L/min) minimum.

One (1) smoothbore of combination nozzle with 2.50" shutoff that flows a minimum of 250 gpm.

One (1) SCBA complying with NFPA 1981 for each assigned seating position, but not fewer than four (4), mounted in brackets fastened to the apparatus or stored in containers supplied by the SCBA manufacturer.

One (1) spare SCBA cylinder for each SCBA carried, each mounted in a bracket fastened to the apparatus or stored in a specially designed storage space(s).

One (1) first aid kit.

Four (4) combination spanner wrenches.

Two (2) hydrant wrenches.

One (1) double female 2.50" (65 mm) adapter with National Hose threads.

One (1) double male 2.50" (65 mm) adapter with National Hose threads.

One (1) rubber mallet, for use on suction hose connections.

Two (2) salvage covers each a minimum size of 12 ft x 14 ft (3.7 m x 4.3 m).

One (1) traffic vest for each seating position, each vest to comply with ANSI/ISEA 207, Standard for High Visibility Public Safety Vests, and have a five-point breakaway feature that includes two (2) at the shoulders, two (2) at the sides, and one (1) at the front.

Five (5) fluorescent orange traffic cones not less than 28.00" (711 mm) in height, each equipped with a 6.00" (152 mm) retro-reflective white band no more than 4.00" (152 mm) from the top of the cone, and an additional 4.00" (102 mm) retro-reflective white band 2.00" (51 mm) below the

6.00" (152 mm) band.

Five (5) illuminated warning devices such as highway flares, unless the five (5) fluorescent orange traffic cones have illuminating capabilities.

One (1) automatic external defibrillator (AED).

Four (4) ladder belts meeting the requirements of NFPA 1983, Standard on Fire Service Life Safety Rope and System Components (if equipped with an aerial device).

If the supply hose carried does not use sexless couplings, an additional double female adapter and double male adapter, sized to fit the supply hose carried, will be carried mounted in brackets fastened to the apparatus.

If none of the pump intakes are valved, a hose appliance that is equipped with one or more gated intakes with female swivel connection(s) compatible with the supply hose used on one side and a swivel connection with pump intake threads on the other side will be carried. Any intake connection larger than 3.00" (75 mm) will include a pressure relief device that meets the requirements of 16.6.6.

If the apparatus does not have a 2.50" National Hose (NH) intake, an adapter from 2.50" NH female to a pump intake will be carried, mounted in a bracket fastened to the apparatus if not already mounted directly to the intake.

If the supply hose carried has other than 2.50" National Hose (NH) threads, adapters will be carried to allow feeding the supply hose from a 2.50" NH thread male discharge and to allow the hose to connect to a 2.50" NH female intake, mounted in brackets fastened to the apparatus if not already mounted directly to the discharge or intake.
0602407 Soft Suction Hose, Provided by Fire
Department, Pumper NFPA 2016
Classification

SOFT SUCTION HOSE PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, section 5.8.2.1 requires a minimum of 20' of suction hose or 15' of supply hose will be carried.

Hose is not on the apparatus as manufactured. The fire department will provide suction or supply hose.
0027023 No Strainer Required
0602538 Extinguisher, Dry Chemical, Pumper
NFPA 2016 Class, Provided by Fire
Department

DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, section 5.9.4 requires one (1) approved dry chemical portable fire extinguisher with a minimum 80-B:C rating mounted in a bracket fastened to the apparatus.

The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0602360 Extinguisher, 2.5 Gal. Pressurized
Water, Pumper NFPA 2016,Provided
by Fire Dept

WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, section 5.9.4 requires one (1) 2.5 gallon or larger water extinguisher mounted in a bracket fastened to the apparatus.

The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0602679 Axe, Flathead, Pumper NFPA 2016
Classification, Provided by Fire
Department

FLATHEAD AXE PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, Section 5.9.4 requires one (1) flathead axe mounted in a bracket fastened to the apparatus.

The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe.

Bid #: 933 45 2.54
0602667 Axe, Pickhead, Pumper NFPA 2016
Classification, Provided by Fire
Department

PICKHEAD AXE PROVIDED BY FIRE DEPARTMENT
NFPA 1901, 2016 edition, Section 5.9.4 requires one (1) pickhead axe mounted in a bracket fastened to the apparatus.

The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe.
0741569 Paint Process / Environmental
Requirements, Appleton

PAINT PROCESS
The exterior custom cab and body painting procedure will consist of a seven (7) step finishing process as follows:

Manual Surface Preparation - All exposed metal surfaces on the custom cab and body will be thoroughly cleaned and prepared for painting. Imperfections on the exterior surfaces will be removed and sanded to a smooth finish. Exterior seams will be sealed before painting. Exterior surfaces that will not be painted include; chrome plating, polished stainless steel, anodized aluminum and bright aluminum treadplate.

Chemical Cleaning and Pretreatment - All surfaces will be chemically cleaned to remove dirt, oil, grease, and metal oxides to ensure the subsequent coatings bond well. The aluminum surfaces will be properly cleaned and treated using a high pressure, high temperature 4 step Acid Etch process. The steel and stainless surfaces will be properly cleaned and treated using a high temperature 3 step process specifically designed for steel or stainless. The chemical treatment converts the metal surface to a passive condition to help prevent corrosion.

Surfacer Primer - The Surfacer Primer will be applied to a chemically treated metal surface to provide a strong corrosion protective basecoat. A minimum thickness of 2 mils of Surfacer Primer is applied to surfaces that require a Critical aesthetic finish. The Surfacer Primer is a twocomponent high solids urethane that has excellent sanding properties and an extra smooth finish when sanded.

Finish Sanding - The Surfacer Primer will be sanded with a fine grit abrasive to achieve an ultrasmooth finish. This sanding process is critical to produce the smooth mirror like finish in the topcoat.

Sealer Primer - The Sealer Primer is applied prior to the Basecoat in all areas that have not been previously primed with the Surfacer Primer. The Sealer Primer is a two-component high solids urethane that goes on smooth and provides excellent gloss hold out when topcoated.

Basecoat Paint - Two coats of a high performance, two component high solids polyurethane basecoat will be applied. The Basecoat will be applied to a thickness that will achieve the proper color match. The Basecoat will be used in conjunction with a urethane clear coat to provide protection from the environment.

Clear Coat - Two (2) coats of Clear Coat will be applied over the Basecoat color. The Clear Coat is a two-component high solids urethane that provides superior gloss and durability to the exterior surfaces. Lap style and roll-up doors will be Clear Coated to match the body. Paint warranty for the roll-up doors will be provided by the roll-up door manufacturer.

After the cab and body are painted, the color will be verified to make sure that it matches the color standard. Electronic color measuring equipment will be used to compare the color sample to the color standard entered into the computer. Color specifications will be used to determine the color match. A Delta E reading will be used to determine a good color match within each family color.

All removable items such as brackets, compartment doors, door hinges, and trim will be removed and painted separately if required, to ensure paint behind all mounted items. Body assemblies that cannot be finish painted after assembly will be finish painted before assembly.

The paint finish quality levels for critical areas of the apparatus (cab front and sides, body sides and doors, and boom lettering panels) are to meet or exceed Cadillac/General Motors GMW15777 global paint requirements. Orange peel levels are to meet or exceed the #6 A.C.T.standard in critical areas. The manufacture's written paint standards will be available upon request.

Environmental Impact
Contractor will meet or exceed all current state regulations concerning paint operations. Pollution control will include measures to protect the atmosphere, water and soil. Controls will include the following conditions:

Topcoats and primers will be chrome and lead free.

Metal treatment chemicals will be chrome free. The wastewater generated in the metal treatment process will be treated on-site to remove any other heavy metals.

Particulate emission collection from sanding operations will have a 99.99 percent efficiency factor.

Particulate emissions from painting operations will be collected by a dry filter or water wash process. If the dry filter is used, it will have an efficiency rating of 98 percent. Water wash systems will be 99.97 percent efficient
Water from water wash booths will be reused. Solids will be removed on a continual basis to keep the water clean.

Paint wastes are disposed of in an environmentally safe manner.

Empty metal paint containers will be recycled to recover the metal.

Solvents used in clean-up operations will be recycled on-site or sent off-site for distillation and returned for reuse.

Additionally, the finished apparatus will not be manufactured with or contain products that have ozone depleting substances. Contractor will, upon demand, present evidence that the manufacturing facility meets the above conditions and that it is in compliance with his state EPA rules and regulations.
0709566 Paint, Two-Tone Color, Enforcer

TWO-TONE CAB PAINT
The cab will be painted two-tone with the upper section painted #10 white and the lower section painted #90 red. There will be a standard two-tone cab paint break provided.

There will be a standard cab shield provided.
0709845 Paint, Single Color, Body

BODY PAINT
The body will be painted to match the lower section of the cab.

Bid #: 933 46 2.55
0646901 Paint Chassis Frame Assy, With
Liner, E-Coat, Standard

PAINT CHASSIS FRAME ASSEMBLY
The chassis frame assembly will be finished with a single system black top coat before the installation of the cab and body, and before installation of the engine and transmission assembly, air brake lines, electrical wire harnesses, etc.

Components that are included with the chassis frame assembly that will be painted are:

Frame rails
Frame liners
Cross members
Axles
Suspensions
Steering gear
Battery boxes
Bumper extension weldment
Frame extensions
Body mounting angles
Rear Body support substructure (front and rear)
Pump house substructure
Air tanks
Steel fuel tank
Castings
Individual piece parts used in chassis and body assembly Components treated with epoxy E-coat protection prior to paint:

Two (2) C-channel frame rails
Two (2) frame liners
The E-coat process will meet the technical properties shown. 0693797 No Paint Required, Aluminum Front
Wheels
0693792 No Paint Required, Aluminum Rear
Wheels
0733739 Paint, Axle Hubs

AXLE HUB PAINT
All axle hubs will be painted black #101.
0007230 Compartment, Painted, Spatter Gray

COMPARTMENT INTERIOR PAINT
The interior of all compartments will be painted with a gray spatter finish for ease of cleaning and to make it easier to touch up scratches and nicks.
0544124 Reflective Band, 1"-4"-1"

REFLECTIVE STRIPES
Three (3) reflective stripes will be provided across the front of the vehicle and along the sides of the body. The reflective band will consist of a 1.00" white stripe at the top with a 1.00" gap then a

4.00" white stripe with a 1.00" gap and a 1.00" white stripe on the bottom. 0007356 Reflective across Cab Face

The reflective band provided on the cab face will be at the headlight level. 0536954 Stripe, Chevron, Rear, Diamond
Grade, Pumper

REAR CHEVRON STRIPING
There will be alternating chevron striping located on the rear-facing vertical surface of the apparatus. The rear surface, excluding the rear compartment door, will be covered.

The colors will be red and yellow diamond grade.

Each stripe will be 6.00" in width.

This will meet the requirements of the current edition of NFPA 1901, which states that 50% of the rear surface will be covered with chevron striping.
0065687 Stripe, Reflective, Cab Doors Interior

CAB DOOR REFLECTIVE STRIPE
A 6.00" x 16.00" black reflective stripe will be provided across the interior of each cab door. The stripe will be located approximately 1.00" up from the bottom, on the door panel.

This stripe will meet the NFPA 1901 requirement.
0033179 Lettering Specifications, Reflective

0686159 Lettering, Reflective, 3.00", (41-60)

LETTERING
Forty-one (41) to sixty (60) reflective lettering, 3.00" high, with outline and shade will be provided. 0686013 Lettering, Reflective, 6.00", Each

LETTERING
There will be reflective lettering, 6.00" high, with outline and shade provided.  There will be 12 letters provided.

Bid #: 933 47 2.56
0686018 Lettering, Reflective, 5.00", Each

LETTERING
There will be reflective lettering, 5.00" high, with outline and shade provided.  There will be four (4) letters provided.
0686033 Lettering, Reflective, 4.00", Each

LETTERING
There will be reflective lettering, 4.00" high, with outline and shade provided.  There will be 21 letters provided.
0772003 Manual, Fire Apparatus Parts, USB
Flash Drive, Custom

FIRE APPARATUS PARTS MANUAL
There will be one (1) custom parts manual(s) in USB flash drive format for the complete fire apparatus provided.

The manual(s) will contain the following:

Job number
Part numbers with full descriptions
Table of contents
Parts section sorted in functional groups reflecting a major system, component, or assembly Parts section sorted in alphabetical order
Instructions on how to locate parts
Each manual will be specifically written for the chassis and body model being purchased. It will not be a generic manual for a multitude of different chassis and bodies.

Service Parts Internet Site
The service parts information included in these manuals are also available on the Pierce website.

The website offers additional functions and features not contained in this manual, such as digital photographs and line drawings of select items. The website also features electronic search tools to assist in locating parts quickly.
0772037 Manual, Chassis Service, USB Flash
Drive, Custom

CHASSIS SERVICE MANUALS
There will be one (1) chassis service manuals on USB flash drives containing parts and service information on major components provided with the completed unit.

The manual will contain the following sections:

Job number
Table of contents
Troubleshooting
Front Axle/Suspension
Brakes
Engine
Tires
Wheels
Cab
Electrical, DC
Air Systems
Plumbing
Appendix
The manual will be specifically written for the chassis model being purchased. It will not be a generic manual for a multitude of different chassis and bodies. 0773381 Manual, Chassis Operation, (1) USB
Flash Drive, Custom

CHASSIS OPERATION MANUAL
The chassis operation manual will be provided on one (1) USB flash drive. 0030008 Warranty, Basic, 1 Year, Apparatus,
WA0008
ONE (1) YEAR MATERIAL AND WORKMANSHIP
A Pierce basic apparatus limited warranty certificate, WA0008, is included with this proposal. 0696698 Warranty, Engine, Cummins, 5 Year,
WA0181

ENGINE WARRANTY
A Cummins five (5) year limited engine warranty will be provided. A limited warranty certificate, WA0181, is included with this proposal.
0684953 Warranty, Steering Gear, Sheppard
M110, 3 Year WA0201

STEERING GEAR WARRANTY
A Sheppard three (3) year limited steering gear warranty will be provided. A copy of the warranty certificate will be submitted with the bid package.
0596017 Warranty, Frame, 50 Year, Custom
Chassis, WA0013
FIFTY (50) YEAR STRUCTURAL INTEGRITY
The Pierce custom chassis frame limited warranty certificate, WA0013, is included with this proposal.
0595698 Warranty, Axle, 3 Year, TAK-4,
WA0050
FRONT AXLE THREE (3) YEAR MATERIAL AND WORKMANSHIP WARRANTY The Pierce TAK-4 suspension limited warranty certificate, WA0050, is included with this proposal. 0610485 Warranty, Axle, Eaton/Dana, 5
Year/100,000 Mile, Parts and Labor

REAR AXLE WARRANTY
A Eaton five (5)-year/100,000 mile parts and labor warranty will be provided.

Bid #: 933 48 2.57
0652758 Warranty, ABS Brake System, 3
Year, Meritor Wabco, WA0232

ABS BRAKE SYSTEM THREE (3) YEAR MATERIAL AND WORKMANSHIP

WARRANTY
A Meritor Wabco™ ABS brake system limited warranty certificate, WA0232, is included with this proposal.
0019914 Warranty, Structure, 10 Year, Custom
Cab, WA0012
TEN (10) YEAR STRUCTURAL INTEGRITY
The Pierce custom cab limited warranty certificate, WA0012, is included with this proposal. 0744240 Warranty, Paint, 10 Year, Cab, ProRate, WA0055 TEN (10) YEAR PRO-RATED PAINT AND CORROSION A Pierce cab limited pro-rated paint warranty certificate, WA0055, is included with this proposal. 0695416 Warranty, Pierce Camera System,
WA0188

CAMERA SYSTEM WARRANTY
A Pierce fifty four (54) monthwarranty will be provided for the camera system. 0647720 Warranty, Pierce LED Strip Lights,
WA0203

COMPARTMENT LIGHT WARRANTY
The Pierce 12 volt DC LED strip lights limited warranty certificate, WA0203, is included with this proposal.
0046369 Warranty, 5-year EVS Transmission,
Standard Custom, WA0187

TRANSMISSION WARRANTY
The transmission will have a five (5) year/unlimited mileage warranty covering 100 percent parts and labor. The warranty will be provided by Allison Transmission.

Note: The transmission cooler is not covered under any extended warranty you may be getting on your Allison Transmission. Please review your Allison Transmission warranty for coverage limitations.
0685945 Warranty, Transmission Cooler,
WA0216

TRANSMISSION COOLER WARRANTY
The transmission cooler will carry a five (5) year parts and labor warranty (exclusive to the transmission cooler).  In addition, a collateral damage warranty will also be in effect for the first three (3) years of the warranty coverage and will not exceed $10,000 per occurrence.  A copy of the warranty certificate will be submitted with the bid package. 0688798 Warranty, Water Tank, Lifetime, UPF,
Poly Tank, WA0195

WATER TANK WARRANTY
A UPF poly water tank limited warranty certificate, WA0195, is included with this proposal. 0596025 Warranty, Structure, 10 Year, Body,
WA0009
TEN (10) YEAR STRUCTURAL INTEGRITY
The Pierce apparatus body limited warranty certificate, WA0009, is included with this proposal. 0693126 Warranty, AMDOR, Roll-up Door, 10
Year/5 Year Painted, WA0185

ROLL UP DOOR MATERIAL AND WORKMANSHIP WARRANTY
An AMDOR roll-up door limited warranty will be provided. The roll-up door will be warranted against manufacturing defects for a period of ten (10) years. A five (5) year limited warranty will be provided on painted roll up doors.

The limited warranty certificate, WA0185, is included with this proposal. 0734463 Warranty, Pump, Waterous, 7 Year
Parts, WA0382

PUMP WARRANTY
The Waterous pump will be provided with a Seven (7) yearmaterial and workmanship limited warranty.

A copy of the warranty certificate will be submitted with the bid package (no exception). 0648675 Warranty, 10 Year S/S Pumbing,
WA0035
TEN (10) YEAR PUMP PLUMBING WARRANTY
The Pierce apparatus plumbing limited warranty certificate, WA0035, is included with this proposal.
0657990 Warranty, Foam System, Husky 3,
WA0231

FOAM SYSTEM WARRANTY
The Husky 3 foam system limited warranty certificate, WA0231, is included with this proposal. 0595820 Warranty, Paint, 10 Year, Body, ProRate, WA0057 TEN (10) YEAR PRO-RATED PAINT AND CORROSION A Pierce body limited pro-rated paint warranty certificate, WA0057, is included with this proposal. 0595412 Warranty, Graphics Lamination, 1
Year, Apparatus, WA0168

ONE (1) YEAR MATERIAL AND WORKMANSHIP
The Pierce graphics fading and deterioration limited warranty limited warranty certificate, WA0168, is included with this proposal.

Bid #: 933 49 2.58
0683627 Certification, Vehicle Stability,
CD0156

VEHICLE STABILITY CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the apparatus complies with NFPA 1901, current edition, section 4.13, Vehicle Stability.  The certification will be provided at the time of bid.
0736238 Certification, Engine Installation,
Saber FR/Enf, Cummins L9, 2021

ENGINE INSTALLATION CERTIFICATION
The fire apparatus manufacturer will provide a certification, along with a letter from the engine manufacturer stating they approve of the engine installation in the bidder's chassis. The certification will be provided at the time of delivery. 0686786 Certification, Power Steering,
CD0098

POWER STEERING CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the power steering system as installed meets the requirements of the component supplier.  The certification will be provided at the time of bid.
0631980 Certification, Cab Integrity, Saber
FR/Enforcer, CD0130

CAB INTEGRITY CERTIFICATION
The fire apparatus manufacturer will provide a cab crash test certification with this proposal. The certification will state that a specimen representing the substantial structural configuration of the cab has been tested and certified by an independent third party test facility. Testing events will be documented with photographs, real-time and high-speed video, vehicle accelerometers, cart accelerometers, and a laser speed trap. The fire apparatus manufacturer will provide a state licensed professional engineer to witness and certify all testing events. Testing will meet or exceed the requirements below:

European Occupant Protection Standard ECE Regulation No.29.

SAE J2422 Cab Roof Strength Evaluation - Quasi-Static Loading Heavy Trucks.

SAE J2420 COE Frontal Strength Evaluation - Dynamic Loading Heavy Trucks.

Roof Crush
The cab will be subjected to a roof crush force of 22,500 lb. This value meets the ECE 29 criteria, and is equivalent to the front axle rating up to a maximum of ten (10) metric tons.

Side Impact
The same cab will be subjected to dynamic preload where a 13,275-lb moving barrier is slammed into the side of the cab at 5.50 mph, striking with an impact of 13,000 ft-lb of force. This test is part of the SAE J2422 test procedure and more closely represents the forces a cab will see in a rollover incident.

Frontal Impact
The same cab will withstand a frontal impact of 32,600 ft-lb of force using a moving barrier in accordance with SAE J2420.

Additional Frontal Impact
The same cab will withstand a frontal impact of 65,200 ft-lb of force using a moving barrier. (Twice the force required by SAE J2420)
The same cab will withstand all tests without any measurable intrusion into the survival space of the occupant area.
0631973 Certification, Cab Door Durability,
Saber FR/Enforcer, CD0137

CAB DOOR DURABILITY CERTIFICATION
Robust cab doors help protect occupants. Cab doors will survive a 200,000 cycle door slam test where the slamming force exceeds 20 G's of deceleration. The bidder will certify that the sample doors similar to those provided on the apparatus have been tested and have met these criteria without structural damage, latch malfunction, or significant component wear. 0631978 Certification, Windshield Wiper
Durability, Saber FR/Enforcer,
CD0132

WINDSHIELD WIPER DURABILITY CERTIFICATION
Visibility during inclement weather is essential to safe apparatus performance. Windshield wipers will survive a 3 million cycle durability test in accordance with section 6.2 of SAE J198 Windshield Wiper Systems - Trucks, Buses and Multipurpose Vehicles. The bidder will certify that the wiper system design has been tested and that the wiper system has met these criteria. 0556828 Certification, Electric Window, Not
Available
0631977 Certification, Seat Belt Anchors and
Mounting, Saber FR/Enforcer,
CD0134

SEAT BELT ANCHOR STRENGTH
Seat belt attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat belt anchor design will withstand 3000 lb of pull on both the lap and shoulder belt in accordance with FMVSS 571.210 Seat Belt Assembly Anchorages.

The bidder will certify that each anchor design was pull tested to the required force and met the appropriate criteria.

SEAT MOUNTING STRENGTH
Seat attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat mounting design will be tested to withstand 20 G's of force in accordance with FMVSS 571.207 Seating Systems. The bidder will certify, at time of delivery, that each seat mount and cab structure design was pull tested to the required force and met the appropriate criteria.

Bid #: 933 50 2.59
0631976 Certification, Cab Heater and
Defroster, Saber FR/Enforcer,
CD0131

CAB DEFROSTER CERTIFICATION
Visibility during inclement weather is essential to safe apparatus performance. The defroster system will clear the required windshield zones in accordance with SAE J381 Windshield Defrosting Systems Test Procedure And Performance Requirements - Trucks, Buses, And Multipurpose Vehicles.The bidder will certify that the defrost system design has been tested in a cold chamber and passes the SAE J381 criteria.

CAB HEATER CERTIFICATION
Good cab heat performance and regulation provides a more effective working environment for personnel, whether in-transit, or at a scene. The cab heaters will warm the cab 77 degrees Fahrenheit from a cold-soak, within 30 minutes when tested using the coolant supply methods found in SAE J381. The bidder will certify, at time of delivery, that a substantially similar cab has been tested and has met these criteria.
0631971 Certification, Cab Air Conditioning
Performance, Saber FR/Enforcer,
CD0135

CAB AIR CONDITIONING PERFORMANCE CERTIFICATION
Good cab air conditioning temperature and air flow performance keeps occupants comfortable, reduces humidity, and provides a climate for recuperation while at the scene. The cab air conditioning system will cool the cab from a heat-soaked condition at 100 degrees Fahrenheit to an average of 78 degrees Fahrenheit in 30 minutes. The bidder will certify that a substantially similar cab has been tested and has met these criteria. 0735949 Certification, Cab HVAC System
Performance, SFR/Enf,
CD0165/CD0167/CD0174/CD0175

PERFORMANCE CERTIFICATIONS
Cab Air Conditioning
Good cab air conditioning temperature and air flow performance keeps occupants comfortable, reduces humidity, and provides a climate for recuperation while at the scene. The cab air conditioning system will cool the cab from a heat-soaked condition at 100 degrees Fahrenheit to an average of 78 degrees Fahrenheit in 30 minutes. The bidder will certify that a substantially similar cab has been tested and has met these criteria.

Cab Defroster
Visibility during inclement weather is essential to safe apparatus performance. The defroster system will clear the required windshield zones in accordance with SAE J381 Windshield Defrosting Systems Test Procedure And Performance Requirements - Trucks, Buses, And Multipurpose Vehicles.The bidder will certify that the defrost system design has been tested in a cold chamber and passes the SAE J381 criteria.

Cab Auxiliary Heater
Good cab heat performance and regulation provides a more effective working environment for personnel, whether in-transit, or at a scene. An auxiliary cab heater will warm the cab 77 degrees Fahrenheit from a cold-soak, within 30 minutes when tested using the coolant supply methods found in SAE J381. The bidder will certify, at time of delivery, that a substantially similar cab has been tested and has met these criteria.
0545073 Amp Draw Report, NFPA Current
Edition

AMP DRAW REPORT
The bidder will provide, at the time of bid and delivery, an itemized print out of the expected amp draw of the entire vehicle's electrical system.

The manufacturer of the apparatus will provide the following:

Documentation of the electrical system performance tests.

A written load analysis, which will include the following:

The nameplate rating of the alternator.

The alternator rating under the conditions specified per:

Applicable NFPA 1901 or 1906 (Current Edition).

The minimum continuous load of each component that is specified per:

Applicable NFPA 1901 or 1906 (Current Edition).

Additional loads that, when added to the minimum continuous load, determine the total connected load.

Each individual intermittent load.

All of the above listed items will be provided by the bidder per the applicable NFPA 1901 or 1906 (Current Edition).
0002758 Amp Draw, NFPA/ULC Radio
Allowance

0799247 Appleton/Florida Stock Unit

0000018 PUMPER, 2ND GEN

0000012 PIERCE CHASSIS
0004713 ENGINE, OTHER
0046395 EVS 3000 Series TRANSMISSION
Bid #: 933 51 2.60
0020011 WATEROUS PUMP

0020009 POLY TANK

0028048 FOAM SYSTEM
0020006 SIDE CONTROL
0020007 AKRON VALVES

0020015 ABS SYSTEM

0658751 PUMPER BASE

Bid #: 933 52 2.61
Turning Performance Analysis
Bid Number: 933 Chassis: Enforcer Chassis
Department: CITY OF SANTA CRUZ FIRE DEPT Body: Pumper, Medium, Aluminum, 2nd Gen Parameters:
*Inside Cramp Angle: 45°
Axle Track: 86.17 in.

Wheel Offset: 3.12 in.

Tread Width: 12.4 in.

Chassis Overhang: 65.95 in.

Additional Bumper Depth: 19 in.

Front Overhang: 84.95 in.

Wheelbase: 191.5 in.

Calculated Turning Radii:

Inside Turn: 15 ft. 2 in.

Curb to curb: 28 ft. 11 in.

Wall to wall: 33 ft. 2 in.

Notes:
*Actual Inside cramp angle may be less than shown.

Curb to Curb turning radius calculated for 9.00 inch curb. 11/01/2022
Category Option Description
Bumpers 0606441 Bumper, 19" Extended, Steel Painted, Saber FR/Enforcer Wheels, Front 0019575 Wheels, Front, Alcoa, 22.50" x 9.00", Aluminum, Hub Pilot Tires, Front 0582936 Tires, Front, Goodyear, G289 WHA, 315/80R22.50, 20 ply Axle, Front, Custom 0633906 Axle, Front, Oshkosh TAK-4, Non Drive, 18,000 lb, Enforcer

2.62 Definitions:

Inside CrampAngle Maximum turning angle of the front inside fire.

Axle Track King-pin to King-pin distance of front axle.

Wheel Offset Offset from the center line of the wheel to the King-pin.

Tread Width Width of the tire tread.

Chassis Overhang Distance of the center line of the front axle to the front edge of the cab. This does not include the bumper depth.

Additional Bumper Wheel Depth that the bumper assembly adds to the front overhang.

Wheelbase Distance between the center lines of the vehicles front and rear axles.

Inside Turning Radius Radius of the smallest circle around which the vehicle can turn.

Curb to Curb Turning Radius Radius of the smallest circle around which the vehicle's tires can turn. This measures assumes a curb height of 9 inches.

Wall to Wall Turning Radius Radius of the smallest circle around which the vehicle's tires can turn. This measures takes into account any front overhang due to chassis , bumper extensions and or aerial devices.

2.63 Option Description Type* Minimum
Load
Intermittent
Load
Total
Connected
0001244 High Idle w/Electronic Engine, Custom 0.00 1.20 0.00 0002526 Light, Engine Compt, All Custom Chassis 0.00 1.60 0.00 0005945 Light, Pump Compt 0.00 1.80 0.00
0010670 ABS Wabco Brake System, Single rear axle 0.00 6.00 0.00 0015216 Reel, Booster, Aluminum - Over Pump, Right Side 0.00 36.00 0.00 0072153 Primer, Trident, Air Prime, Air Operated 0.00 0.01 0.00 0079166 Batteries, (4) Exide Grp 31, 950 CCA ea, Threaded Stud 0.00 3.00 0.00 0543751 Light, Do Not Move Apparatus 0.00 0.80 0.00
0548004 Wiring, Spare, 15 A 12V DC 1st 0.00 0.00 15.00
0548006 Wiring, Spare, 15 A 12V DC 2nd 0.00 0.00 15.00
0549333 Indicators, Engine, Included with Pressure Controller 0.00 0.35 0.00 0561471 Lights, Backup, Wln M6BUW, LED, For Tail Lt Housing 0.00 3.20 0.00 0589905 Alarm, Back-up Warning, PRECO 1040 0.00 0.50 0.00 0598966 Lights, Side Scene, FRC SPA900-Q70 Surface Mt, 2nd 0.00 0.00 12.00 0598967 Lights, Side Scene, FRC SPA900-Q70 Surface Mt, 1st 0.00 0.00 12.00 0602637 Portable Hand Light, Provided by Fire Dept, Pumper NFPA 2016 Classification

0.00 0.50 0.00
0604354 Gauge, Foam Level, FRC, Tank Vision Pro, WLA 360-A00, Class "A"

0.00 0.00 1.23
0624939 Foam Sys, Husky 3, Single Agent, Multi Select Feature 0.00 55.00 0.00 0644201 Cab Lift, Elec/Hyd, Saber FR/Enforcer 0.00 180.00 0.00 0645611 Lights, Rear Scene, FRC, SPA900-Q70, Surface Mt, 1st 0.00 0.00 12.00 0653533 Camera, Pierce, 7" LCD, Rear Camera Only 0.00 1.20 0.00 0653937 Flasher, Headlight Alternating 0.00 0.00 0.08
0687994 Engine Brake, Jacobs Compression Brake, Cummins Engine 0.00 0.42 0.00 0768415 Light Twr, W-B Chf NS1.8-2 WHL, 2-P*H2 12VDC Lts Cld 6' 0.00 0.00 48.00 0776075 Light, Visor, Wln, 12V P*H1* Pioneer LED 1st 0.00 0.00 6.50 0797189 Wiring, Spare, 4.8 A 12V DC, USB Termination Blue Sea 1045 1st 0.00 0.00 2.50 0802935 Light, Directional, Wln M62T* LED, Cmn Bzl, Above Headlights, Sab/Enf

0.00 1.50 0.00
0895310 Siren, Federal Q2B 0.00 100.00 0.00
0722696 HVAC, Enforcer, CARE Load Managed 0.00 0.00 100.00 0002758 Amp Draw, NFPA/ULC Radio Allowance NFPA 5.00 0.00 0.00 0023650 LS 152" Rollup, Full Height Front & Rear, FDLER NFPA 4.50 0.00 4.50 0062586 Gauge, Water Level, Class 1, Pierce Std NFPA 1.23 0.00 0.00 0063658 RS 152" Rollup, Full Height Front & Rear, FDLER NFPA 4.50 0.00 4.50 0083701 Compt, Rear, Rollup, 44.50" FF, 25.88" D NFPA 0.90 0.00 0.90 0556360 Lights, Step, P25 LED 4lts, Pump Pnl Sw NFPA 1.00 0.00 0.00 0586382 Gauges, Engine, Included With Pressure Controller NFPA 0.30 0.00 0.00 0593161 Light Shield, S/S LED NFPA 3.00 0.00 0.00
0605126 Pump Shift, Air Mnl Override, Split Shaft, Interlocked, Waterous NFPA 1.00 0.00 0.00 0610240 Vehicle Data Recorder w/Seat Belt Monitor NFPA 0.50 0.00 0.00 0617866 Lights, Perimeter Pump House, Truck-Lite 6060C LED 2lts NFPA 0.50 0.00 0.00 0618791 DEF Tank, 4.5 Gallon, DS Fill, Forward of Axle, Common Air Bottle Door
NFPA 0.60 11.40 0.00
0620054 Light, Directional/Marker, Intermediate, Weldon 9186-8580-29 LED 2lts
NFPA 0.10 0.90 0.00
0625650 Cab, Enforcer, 7000 NFPA 6.80 10.20 0.00
0627282 Lights, Clearance/Marker/ID, Rear, FRP LED Bar & P25 LED 4Lts NFPA 1.75 0.00 0.00 0644176 Load Manager, Integrated In Electrical System, Saber FR/Enforcer NFPA 0.56 0.56 0.00 0644187 Cab Instruments, Black Gauges, Black Bezels, Saber FR/Enforcer NFPA 1.26 0.00 0.00 0644228 Air Dryer, Wabco System Saver 1200 IWT, Heated, 10" Frame, Standen, SFR/Enf
NFPA 7.81 0.00 0.00
* UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 1 Electrical Analysis 11/1/2022
Bid #: 933
Santa Cruz Stock 1500 Pumper Sales Rep:

Organization:

Myers, Rich
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer: CITY OF SANTA CRUZ FIRE DEPT
Option: Electrical Power/Signal Protection & Control, Enforcer Type: Hard Wired

2.64 Option Description Type* Minimum
Load
Intermittent
Load
Total
Connected
0647647 Lights, Dome, FRP Dual LED 4 Lts NFPA 0.80 0.80 0.00 0647802 Lights, Clearance/Marker/ID, Front, P25 LED 5 Lts, Saber FR/Enforcer
NFPA 0.35 0.00 0.00
0647899 Lights, Directional/Marker, Cab Front Side, Weldon 9186-8580-29 LED, Sab/Enf
NFPA 0.80 0.00 0.00
0683575 Lights, Perimeter Body, Truck-Lite 6060C LED 2ts, Rear Step NFPA 0.50 0.00 0.00 0687604 Lights, Perimeter Cab, Truck-Lite 6060C LED 4Dr, Grommet Mt NFPA 2.00 0.00 0.00 0688049 Siren, Federal EQ2B-200, 200 Watt NFPA 2.01 18.13 0.00 0709438 Lights, Walk Surf, FRP Flood, LED NFPA 2.00 0.00 0.00 0736437 Engine, Cummins L9, 450 hp, 1250 lb-ft, W/OBD, EPA 2021, Saber FR/Enforcer
NFPA 1.00 0.00 0.00
0739224 Indicator Light @ Pump Panel, Throttle Ready, Incl w/Pressure Gov/Throttle,Green
NFPA 0.10 0.00 0.00
0740422 Lightbar, Wln, Freedom IV-Q, 72", RRWRRR____RRRWRR, Lw Int
NFPA 6.48 2.48 7.44
0740512 Lights, Side Zone Lower, Wln M6**, M6**, M6**, 6lts, Lw Int NFPA 5.52 8.28 0.00 0745392 Lights, Front Zone, Wln M6** LED, in Common Bzl, Lw Int NFPA 1.80 2.70 0.00 0745568 Indicator Light, Pump Panel, Ok To Pump, Green NFPA 0.10 0.00 0.00 0746422 Lights, Rear Zn Lwr, Wln M6*, Lw Int NFPA 1.80 2.70 0.00 0768474 Lights, Hose Bed, Below Alum Cvr, Amdor AY-LB-12HW040, 40" LED 4lts
NFPA 2.40 0.00 0.00
0783157 Headlights, Rect LED, JW Spkr Evo 2, Heat,
AXT/DCF/Enf/Imp/Sab/Vel
NFPA 6.60 6.60 0.00
0783479 Cabinet, Forward Facing, Center, 38.50 W x 50 H x 28 D, Roll, SFR/Enf
NFPA 0.50 0.50 0.00
0791528 Light, Traffic Directing, Wln TAL65, 36.00" Long, TACTL5 NFPA 0.60 1.20 0.00 0794959 Controller, Pressure, Pierce, Pump Boss, PBA300 NFPA 1.80 0.00 0.00 0803250 Light, Rear Zone Up, Wln L31H*FN Beacon, Red LED, DVI High NFPA 3.20 4.80 0.00 0804519 Lights, Tail, Wln M62BTT* Red Stop/Tail & M62T* Amber Dir Arw NFPA 0.83 2.49 0.00 0887561 Trans, Allison 6th Gen, 3000 EVS P, Imp/Vel/SFR/Enf NFPA 2.00 2.00 0.00 0889577 Bracket, License Plate & Light, P25 LED, Stainless Brkt NFPA 0.07 0.00 0.00 0892638 Lights, Cab & Crw Cab Acs Stps, P25, LED w/Bezel, 6lts NFPA 1.00 0.00 0.00 0647729 Alternator, 320 amp, Delco Remy 40SI S 0.00 0.00 0.00 Load Totals: 85.57 468.82 241.65
Minimum Continuous Load
Supply: 187.00
Demand: 85.57
Variance: 101.43
Total Connected Load
Supply: 285.00
Demand: 227.22
Variance: 57.78
Note: Minimum Continous Load is in "Blocking Right of Way" mode.(Reference current edition of NFPA 1901) Note: Intermittent Load items are not factored in on any alternator load comparisons. These items are included on the report for reference only and should be looked at as amp draw exclusion items. (Reference current edition of NFPA 1901) Note: Total Connected Load "Demand" represents Total Connected Load minus any Load Managed items Alternator Output at Idle: 187.00 Alternator Output at Governed Speed: 285.00 * UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 2 Electrical Analysis 11/1/2022
Bid #: 933
Santa Cruz Stock 1500 Pumper Sales Rep:

Organization:

Myers, Rich
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer: CITY OF SANTA CRUZ FIRE DEPT
Option: Electrical Power/Signal Protection & Control, Enforcer Type: Hard Wired

2.65 DEALER

SUPPLIED

PRODUCT
AND/OR

SERVICES
Bid #933

2.66 1
DEALER SUPPLIED EQUIPMENT and/or SERVICES
The following items and/or services will be provided by Golden State Fire Apparatus Inc. (GSFA) prior to final delivery:

LICENSED MANUFACTURER
The State of California Vehicle Code, section 11701 requires “every manufacturer of a vehicle subject to registration shall make application to the Department of Motor Vehicles (DMV) for a license containing a general distinguishing number”. The manufacturer has a current license at time of proposal and shall provide a copy upon request. Temporary licenses are not acceptable.

LICENSED DEALERSHIP
The State of California Vehicle Code, section 11701 requires a “dealer in vehicles of a type subject to registration, shall make application to the Department of Motor Vehicles (DMV) for a license containing a general distinguishing number”. Golden State Fire Apparatus, Inc. has a current license at time of bid as outlined above and is available upon request. Temporary licenses are not acceptable.

LICENSED SALES REPRESENTATIVE
The State of California Vehicle Code, section 11800 requires that it shall be “unlawful for any person to function as a vehicle salesperson without having first procured a license issued by the Department of Motor Vehicles (DMV)”. The representative has a current vehicle salespersons license at time of proposal and shall provide a copy upon request. Temporary licenses are not acceptable.

VEHICLE REGISTRATION
The State of California Vehicle Code section 11739 requires that the “dealer of a new motor vehicle sale is responsible for applying for the title, securing vehicle registration, and obtaining license plates for the Customer” through the Department of Motor Vehicles (DMV). Golden State Fire Apparatus, Inc. is a factory-authorized dealer of the vehicle being sold and is authorized to register with the State of California as a new vehicle manufacturer.

GSFA will make all necessary applications and complete all transfer papers, including applying for California Exempt “E” license plates.

WEEKLY PROGRESS PHOTOGRAPHS
GSFA will provide weekly photographs of the apparatus or the major components as they are being constructed. The photographs will commence at the start of the manufacturing process and will continue through production by the manufacturer. The reports will show the progress of the apparatus through the course of each week. Special attention will be given to show the unique features and aspects of the apparatus as construction progresses.

FINAL INSPECTION, FACTORY TRIP
A final inspection trip to the manufacturing facility will be provided for THREE (3) Customer representative(s). The intent of this trip is to ensure that the apparatus is built to specification and to detect any deficiencies that require correction. The final inspection trip will have a duration of THREE (3) days and TWO (2) nights and be scheduled at times mutually agreed upon between GSFA and the Customer.

Costs for airfare, lodging, meals, and ground transportation while at the manufacturer’s location will be the responsibility of GSFA. Air travel will be from one of the following airports: Sacramento, San Francisco, or San Jose.

Costs such as Customer ground transportation in California, Customer airport parking, Customer luggage fees and Customer incidentals while traveling to the factory will be the responsibility of the Customer.

Flight reservations are non-refundable and in the event of a cancellation after booking, the Customer will

2.67 2
be responsible for all costs associated with this cancellation, which may include not only the original ticket cost but also any change or cancellation fees imposed by the airline and/ or travel agency. Flight reservations are also non-transferable.

INTERCOM SYSTEM
There will be a four (4) position David Clark, Model U3800, intercom system with single radio interface capability at the driver and officer positions and remote radio push to talk buttons located PER SWITCH PANEL LAYOUT. Two (2) crew cab outboard seats will have intercom only capability.

The following components will be provided:
• One (1) U3805 Radio Cord Junction Module
• Two (2) U3815 Radio interface modules (Driver, Officer) • Two (2) Remote Push To Talk Button Kits
• One (1) U3800 Master station (1 Crew)
• One (1) U3801 Remote headset intercom station (1 Crew) • One (1) C3820 Power cord
• All necessary station cables and connectors

RADIO / INTERCOM INTERFACE INCLUDED
All radio interfaced stations will have universal radio interfaces installed. The interface wiring will be routed within the cab to TBD.

OVER THE HEAD HEADSET
There will be four (4) over the head, headset(s) provided D, O, 2 Crew.

Each David Clark, Model H3432, headset will feature:
• 5' Coiled cord
• Noise cancelling electric microphone
• Flexible microphone boom rotates 200 degrees for left or right dress • Microphone on/off button
• Comfort Gel Earseals
• 23 dB noise reduction

HEADSET HANGERS
There will be four (4) headset hanger(s) installed driver's seat, officer's seat, driver's side outboard forward facing seat and passenger's side outboard forward facing seat. The hanger(s) will meet NFPA 1901, Section 14.1.11, requirement for equipment mounting.

ELECTRONIC MOUNTING ALLOWANCE
An electronic (two-way radio and intercom system) mounting allowance of $3,500.00 is included in the bid price to cover the cost of mounting the applicable equipment per the direction of the City of Santa Cruz. If the mounting allowance is exceeded, additional work can be performed at the current published shop rate. Any unused portion of this allowance will be credited back on the final invoice or reimbursed in the form of a check to the City of Santa Cruz.

CHANGE ORDER / CONTINGENCY FUND
A change order / contingency fund in the sum of $10,000 is included in the bid price to cover the cost of change orders, unforeseen items or required work that may come up during construction. Any unused portion of this fund will be credited back on the final invoice or reimbursed in the form of a check to the City of Santa Cruz.

2.68 3

DELIVERY TO AUTHORIZED SERVICE FACILITY
GSFA will, at their expense, deliver the apparatus (including any applicable equipment, spare parts, and supplies) to their Northern California facility in Sacramento for a dealer preparation inspection.

To ensure proper break in of all components while still under warranty, the apparatus shall be delivered under its own power - rail or truck freight shall not be acceptable.

PRE-DELIVERY SERVICE
After transportation from the factory and prior to delivery, the apparatus will receive a pre-delivery service to confirm proper operation and correction of any issues found as a result of said inspection. The Golden State Fire Apparatus, Inc. pre-delivery service consists of the following:
• Engine Compartment and Undercarriage – Check for any broken mounting brackets and inspect for correct capacities of the following (if applicable): engine oil, coolant, power steering fluid, washer reservoir fluid, transmission fluid, rear end fluid, pump transmission oil, and primer oil. • Interior – Operate all doors, windows, and locks for proper adjustment. Check upholstery. • Exterior – Repair reasonable paint scratches or chips. Tighten any loose hardware and inspect tires and wheels for proper pressure and lug torquing.
• Road Test – With the water tank (if applicable) full, the apparatus will be driven approximately twenty miles which allows the drive train components to get up to operating temperature. Road test will be on both city and highway roads. A DOT compliant brake test will be conducted to ensure the system is holding air. The brake condition and wheel seals will also be inspected. • Electrical - Operate all lights, sirens, and other electrical accessories to verify operation. • Pump - If applicable, vacuum test the pump to hold for 15 minutes. After vacuum test, operate the relief valve, transfer valve and check pump shift. Check water tank for leaks and inspect water level gauge for calibration. With discharge caps loose, rapid test all individual gauges and main gauges for calibration. Lubricate valve rods.
• Foam System – If applicable, tighten caps and connect foam lines. Test selector, valves, metering valve and operation of foam system (including flush).
• Fuel Tank - Fuel tank will be filled at the dealership location prior to final delivery. • DEF Tank - DEF tank will be filled at the dealership location prior to final delivery. • Wash - The apparatus will be thoroughly washed at the dealership location prior to final delivery.

FINAL DELIVERY (CUSTOMER LOCATION)
GSFA will, at their expense, deliver the Product (including any applicable equipment, spare parts, and supplies) to the Customer specified address once completed. Prior to delivery of the Product, Customer agrees to provide proof of liability and physical damage insurance to GSFA. GSFA will not release the Product to the Customer until such proof of insurance is provided.

2.69 4
It is the responsibility of the Customer to have any outstanding balance due, paid in full to GSFA, prior to or at the time that the Product is complete and ready to deliver. If payment is late or delivery is delayed pending payment, a daily finance charge of $150.00 and a daily storage fee of $50.00 may apply until such payment is received.

Due to insurance liability, the Product will not be delivered without full acceptance and full payment (or prior written agreement between the Customer and GSFA).

END OF DEALER SUPPLIED EQUIPMENT and/or SERVICES

2.70 PRODUCT

WARRANTIES
Exhibit “C”
Bid #933

2.71 Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0008

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

No specific exclusions apply
Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:

One (1) Year Material and Workmanship
Basic Apparatus
Twelve (12) months. Warranty Period
Ends After:

The date the apparatus is placed in service, or 60 days from the original buyer invoice date, whichever comes first. Warranty Begins:

Portions of the apparatus manufactured by Pierce shall be free from defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

2.72 Cummins Warranty
Worldwide
Fire Apparatus/Crash Trucks

2.73 Coverage
Products Warranted
This Warranty applies to new diesel Engines sold by
Cummins and delivered to the first user on or after
April 1, 2007, that are used in fire apparatus truck and crash truck* applications Worldwide.

Base Engine Warranty
The Base Engine Warranty covers any failures of the
Engine which result, under normal use and service,
from a defect in material or factory workmanship
(Warrantable Failure). This Coverage begins with the
sale of the Engine by Cummins and ends five years or
100,000 miles (160,935 kilometers), whichever occurs
first, after the date of delivery of the Engine to the first user.

Engine aftertreatment components included in the
Cummins Critical Parts List (CPL) and marked with a
Cummins part number are covered under Base Engine
Warranty.

Additional Coverage is outlined in the Emission
Warranty section.

These Warranties are made to all Owners in the
chain of distribution and Coverage continues to all
subsequent Owners until the end of the periods of
Coverage.

Cummins
Responsibilities
Cummins will pay for all parts and labor needed to
repair the damage to the Engine resulting from a
Warrantable Failure.

Cummins will pay for the lubricating oil, antifreeze,
filter elements, belts, hoses and other maintenance
items that are not reusable due to the Warrantable
Failure.

Cummins will pay for reasonable labor costs for
Engine removal and reinstallation when necessary to
repair a Warrantable Failure.

Cummins will pay reasonable costs for towing a
vehicle disabled by a Warrantable Failure to the
nearest authorized repair location. In lieu of the towing expense, Cummins will pay reasonable costs for
mechanics to travel to and from the location of the
vehicle, including meals, mileage and lodging when
the repair is performed at the site of the failure.

Owner
Responsibilities
Owner is responsible for the operation and
maintenance of the Engine as specified in Cummins
Operation and Maintenance Manuals. Owner is also
responsible for providing proof that all recommended
maintenance has been performed.

Before the expiration of the applicable Warranty,
Owner must notify a Cummins distributor, authorized
dealer or other repair location approved by Cummins
of any Warrantable Failure and make the Engine
available for repair by such facility. Except for Engines disabled by a Warrantable Failure, Owner must also
deliver the Engine to the repair facility.

Service locations are listed on the Cummins Worldwide
Service Locator at cummins.com.

Owner is responsible for the cost of lubricating oil,
antifreeze, filter elements and other maintenance items provided during Warranty repairs unless such items
are not reusable due to the Warrantable Failure.

Owner is responsible for communication expenses,
meals, lodging and similar costs incurred as a result of a Warrantable Failure.

Owner is responsible for non-Engine repairs and for
‘‘downtime’’ expenses, cargo damage, fines, all
applicable taxes, all business costs and other losses
resulting from a Warrantable Failure.

Owner is responsible for a $100 (U.S. Dollars)
deductible per each service visit under this plan in the 3rd, 4th and 5th years of Base Engine Warranty. The
deductible will not be charged during the first 2 years of the Base Engine Warranty.

Limitations
Cummins is not responsible for failures or damage
resulting from what Cummins determines to be abuse
or neglect, including, but not limited to: operation
without adequate coolants or lubricants; overfueling;
overspeeding; lack of maintenance of lubricating,
cooling or intake systems; improper storage, starting,
warm-up, run-in or shutdown practices; unauthorized
modifications of the Engine.

Any unauthorized modifications to the aftertreatment
could negatively effect emissions certification and void Warranty.

Cummins is also not responsible for failures caused by
incorrect oil, fuel or diesel exhaust fluid or by water, dirt or other contaminants in the fuel, oil or diesel

2.74 exhaust fluid.

This Warranty does not apply to accessories supplied
by Cummins which bear the name of another
company. Such non-warranted accessories include, but
are not limited to: alternators, starters, fans, air
conditioning compressors, clutches, filters,
transmissions, torque converters, vacuum pumps,
power steering pumps, fan drives and air compressors.

Cummins branded alternators and starters are covered
for the first two years from the date of delivery of the Engine to the first user, or the expiration of the Base Engine Warranty, whichever occurs first.

Failures resulting in excessive oil consumption are not covered beyond the duration of the Coverage or
100,000 miles (160,935 kilometers) or 7,000 hours from
the date of delivery of the Engine to the first user,
whichever of the three occurs first. Before a claim for excessive oil consumption will be considered, Owner
must submit adequate documentation to show that
consumption exceeds Cummins published standards.

Failures of belts and hoses supplied by Cummins are
not covered beyond the first year from the date of
delivery of the Engine to the first user or the duration of the Warranty, whichever occurs first.

Parts used to repair a Warrantable Failure may be new
Cummins parts, Cummins approved rebuilt parts or
repaired parts. Cummins is not responsible for failures resulting from the use of parts not approved by
Cummins.

A new Cummins or Cummins approved rebuilt part
used to repair a Warrantable Failure assumes the
identity of the part it replaced and is entitled to the remaining Coverage hereunder.

Cummins Inc. reserves the right to interrogate
Electronic Control Module (ECM) data for purposes of
failure analysis.

CUMMINS DOES NOT COVER WEAR OR WEAROUT
OF COVERED PARTS.

CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.

THIS WARRANTY AND THE EMISSION WARRANTY

SET FORTH HEREINAFTER ARE THE SOLE

WARRANTIES MADE BY CUMMINS IN REGARD TO
THESE ENGINES. CUMMINS MAKES NO OTHER

WARRANTIES, EXPRESS OR IMPLIED, OR OF

MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.

This Warranty gives you specific legal rights, and you
may also have other rights which vary from state to
state.

Emission
Warranty
Products Warranted
This Emission Warranty applies to new Engines
marketed by Cummins that are used in the United
States** in vehicles designed for transporting persons
or property on a street or highway. This Warranty
applies to Engines delivered to the first user on or after September 1, 1992.

Coverage
Cummins warrants to the first user and each
subsequent purchaser that the Engine is designed,
built and equipped so as to conform at the time of sale by Cummins with all U.S. federal emission regulations
applicable at the time of manufacture and that it is free from defects in material or factory workmanship which
would cause it not to meet these regulations within the longer of the following periods: (A) Five years or
100,000 miles (160,935 kilometers) of operation,
whichever occurs first, as measured from the date of
delivery of the Engine to the first user or (B) The Base Engine Warranty.

If the vehicle in which the Engine is installed is
registered in the state of California, a separate
California Emission Warranty also applies.

Limitations
Failures, other than those resulting from defects in
material or factory workmanship, are not covered by
this Warranty.

Cummins is not responsible for failures or damage
resulting from what Cummins determines to be abuse
or neglect, including, but not limited to: operation
without adequate coolants or lubricants; overfueling;
overspeeding; lack of maintenance of lubricating,
cooling or intake systems; improper storage, starting,
warm-up, run-in or shutdown practices; unauthorized
modifications of the Engine.

Any unauthorized modifications to the aftertreatment
could negatively effect emissions certification and void Warranty.

Cummins is also not responsible for failures caused by
incorrect oil, fuel or diesel exhaust fluid or by water, dirt or other contaminants in the fuel, oil or diesel
exhaust fluid.

Cummins is not responsible for non-Engine repairs,
‘‘downtime’’ expenses, cargo damage, fines, all
applicable taxes, all business costs or other losses
resulting from a Warrantable Failure.

2.75 Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.

Bulletin 3381161
Printed in U.S.A. Rev. 08/09
©2001 Cummins Inc.

CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.
* Airport operated crash trucks and fire department
operated trucks employed to respond to fires,
hazardous material releases, rescue and other
emergency-type situations.
** United States includes American Samoa, the
Commonwealth of Northern Mariana Islands, Guam,
Puerto Rico and the U.S. Virgin Islands.

Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.

Bulletin 3381161
Printed in U.S.A. Rev. 08/09
2001 Cummins Inc.

2.76 2.77

2.78 2.79

2.80 Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0013

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This warranty does not apply to damage caused by corrosion.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:

Lifetime Fifty (50) Year Structural Integrity
Custom Chassis Frame
Fifty (50) Years
(Expected Life of Apparatus)
Warranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

Custom chassis frame rail manufactured by Pierce shall be free from defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

2.81 This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty excludes brake pads, brake rotors, seal boots and shock absorbers.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Three (3) Years
-or30,000 Miles
Warranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 12/16/2013 WA0050
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

Fire and Rescue Apparatus
Coverage:

Three (3) Year Material and Workmanship
TAK-4 Independent Front Suspension
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The TAK-4 Front Independent Suspension and Steering
Gears shall be free from defects in material and
workmanship.

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

2.82 New for 2011!
Dana Holding Corporation is pleased to announce a change in our standard warranty for fire/rescue vehicles. All steer and drive axles will now come with a 5 year / 100,000 mile warranty. For further information, please go to www.roadranger.com.

Dana Holding Corporation is working with chassis manufactures to supply a 24K front steer beam with a 5 ¼’ drop. We have listened to your requests for a slightly higher GAWR for single axle aerials. Not all fire stations can accommodate a long wheel base application. This allows manufactures to meet the limited length requirements for smaller fire houses. Please submit your requests through our website. Please indicate on the application your need for 24K GAWR.

Finally, our drive axles will accommodate simultaneous auxiliary braking.

Dana axles are built tough and were design with Telma retarders in mind.

Submit your application for single or tandem designation.

Dana Holding Corporation will work with you to provide the best drive train solution with the best warranty in the fire/rescue industry. For additional information please contact:

Alan Manzon
Account Manager – Specialty Markets
Dana Holding Corporation
One Village Center Dr.

Van Buren Twp., MI 48111-5711
Phone: (734)629-1141
Cell: (269)312-3220
[email protected]
Grace Lake Corporate Center
1 Village Center Drive
Van Buren Township, Michigan 48111
www.dana.com

2.83 )LUHDQG5HVFXH$SSDUDWXV Coverage:
7KUHH

<HDU0DWHULDODQG:RUNPDQVKLS
0HULWRU:DEFR$%6%UDNH6\VWHP
Limited Warranty Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The Meritor Wabco ABS brake system shall be covered by
Meritor Wabco as indicated in the attached Meritor Wabco warranty coverage description
/,0,7(':$55$17<
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Three (3) Year Warranty Period
Ends After:

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

The exclusions listed in the attached Meritor Wabco warranty description shall apply.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
(;&/86,212)&216(48(17,$/$1',1&,'(17$/'$0$*(6
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
%8<(5
6(;&/86,9(5(0('<
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/25/2013 WA0232
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
',6&/$,0(562):$55$17,(6
capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

2.84 WARRANTY
Warranty coverage is essential to protecting your investment. But understanding the full details of your coverage can be challenging. This straightforward approach allows you, our valued customer, to better understand how your specific vehicle applications will be covered in your region. Our component warranty coverage is provided according to vocation/usage categories listed below. • Linehaul covers high mileage operation (over 60,000 miles/year) on well-maintained major highways of concrete or asphalt construction.
• General Service covers moderate mileage operations (less than 60,000 miles/year) on well-maintained public roads (less than 10 percent off-road) typically with less than three (3) stops per mile. • Heavy Service (Vocational) covers vehicles with more than 10 percent off-road OR moderate to frequent starts/stops typically with more than three (3) stops per mile.
• Off-Highway Service covers lower mileage operations. Vehicles are not typically licensed for highway use. • The standard aftermarket warranty for WABCO products - including WABCO Original parts, WABCO Reman Solutions, ProVia quality aftermarket parts and WABCO retrofit solutions - is one year, parts only from in-service date when purchased from ZF distributor networks or its affiliates and/or subsidiaries.

MODEL YEAR 2021 VEHICLES
How to Read Warranty Coverage (Example)
Number of Years Mileage (in thousands) Unl=Unlimited P=Parts Only P&L=Parts & Labor 3 300 P

2.85 WARRANTY - MODEL YEAR 2021 VEHICLES
¹ ZF and WABCO branded components. 2
WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve.
• Aerial Ladder Truck
• Aerial Platform
• Ambulance
• Auto Hauler
• Beverage Truck
• Bulk Hauler
• Chip Hauler (Truck)
• Cross Country Coach
• Doubles
• Flatbed
• Front Engine Commercial
Chassis
• Front Engine Integral
Coach
• General Freight
• Grain Hauler
• Intercity Coach
• Intermodal Chassis
• Livestock Hauler
• Meat Packer
• Moving Van
• Municipal Truck
• Pipe Hauler
• Platform Auto Hauler
• Pumper
• Rear Engine Integral Coach
• Recreational Vehicles
• Refrigerated Freight
• School Bus
• Stake Truck
• Tanker
• Tanker Truck
• Triples
• Tour Bus
• Wrecker

LINEHAUL/GENERAL SERVICE VEHICLES

LINEHAUL/GENERAL SERVICE WARRANTY INFORMATION

LINEHAUL TYPICALLY IS
• High mileage operation (over 60,000 miles/year)
• Well maintained major highways of concrete or
asphalt construction

GENERAL SERVICE TYPICALLY IS
• Moderate mileage operations (less than 60,000 miles/year) • Well maintained public roads (less than 10% off-road) • Less than three (3) stops per mile
WABCO Components1
Air Management
Air Brake Valves
Trailer Lift Axle Control Valve 1/100/P&L
Trailer Control Line Filter3
Air Compressors (ALL)2 2/200/P&L
Air Dryers (ALL) 3/300/P&L
Aerodynamics
OptiFlow® TrailerSkirt 2/UnU/P
OptiFlow® Trailer Tail and AutoTail 2/UnI/P
Braking Systems
ABS (Anti-Lock Braking System) Air
3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic
Electronic Braking System (EBS)
Electronic Stability Control (ESC)
Roll Stability Control (RSS)
Trailer Roll Stability Support (RSS)
Trailer ABS (Anti-Lock Braking System)3
Driveline Suspension Control
Clutch Controls 2/200/P&L
Leveling Valves
1/100/P&L
OptiRide® Automated Manual Transmission (AMT)
OptiRide® Electronically Controlled Air Suspension
(ECAS) 3/300/P&L
WABCO Components1 (cont.)
Safety
OnGuardACTIVE®
3/300/P&L
OnLane®
OnLaneALERT®
OnSide®
Trailer SafeStart™
Trailer TailGUARD™
Telematics
TrailerCAST™ Telematics Device 3/300/P&L
Wheel End Solutions
EasyFit™ Slack Adjuster 6/600/P
MAXXUS™ Truck Air Disc Brake 5/500/P&L
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 17 and 19 Air Disc Brake 2/Unl/P and
1/Unl/L
Pan 22 Air Disc Brake 5/500/P and 1/L
TRISTOP™ D Actuator w/ IBV or IRB 6/600/P
TRISTOP™ D Actuator 3/300/P
UNISTOP™ Actuator 2/200/P
Trailer MAXX22T™ Air Disc Brake 5/500/P and 1/L

2.86 1 ZF and WABCO branded components. 2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve.

WABCO Components1
Air Management
Air Brake Valves
1/100/P&L Air Compressors (ALL)2
Air Dryers (ALL)
Trailer Control Line Filter3
Braking Systems
ABS (Anti-Lock Braking System) Air 3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic 2/200/P&L
Electronic Braking System (EBS)
3/300/P&L
Electronic Stability Control (ESC)
Trailer ABS Valve3
Roll Stability Control (RSS)
Trailer Roll Stability Support (RSS)
Driveline Suspension Control
OptiRide® Electronically Controlled Air Suspension
(ECAS) 2/200/P&L
Leveling Valves 1/100/P&L
Clutch Controls 2/200/P&L
Safety
OnGuardACTIVE®
3/300/P&L
OnLane®
OnLaneALERT®
OnSide®
Trailer SafeStart™
Trailer TailGUARD™
Telematics
TrailerCAST™ Telematics Device 3/300/P&L
Wheel End Solutions
EasyFit™ Slack Adjuster 2/200/P
MAXXUS™ Air Disc Brake 1/Unl/P&L
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 22, 19 and 17 Air Disc Brake 1/Unl/P&L
Trailer MAXX22T™ 1/Unl/P&L
TRISTOP™ D Actuator w/ IBV 3/Unl/P
TRISTOP™ D Actuator 2/200/P
UNISTOP™ Actuator 1/100/P
• Airport Rescue Fire (ARF)
• Airport Shuttle
• Asphalt Truck
• Block Truck
• Bottom Dump Trailer
Combination
• Cementing Vehicle
• City Bus
• Commercial Pick-Up
• Concrete Pumper
• Construction Material Hauler
• Crash Fire Rescue (CFR)
• Mixer
• Demolition
• Drill Rig
• Dump
• Emergency Service
• Equipment Hauling
• Flatbed Trailer Hauler
• Flatbed Truck
• Fracturing Truck
• Front Loader
• Geophysical Exploration
• Hopper Trailer Combinations
• Landscaping Truck
• Liquid Waste Hauler
• Log Hauling
• Lowboy
• Michigan Special
Gravel Trains
• Michigan Special
Log Hauler
• Michigan Special
Steel Hauler
• Michigan Special
Waste Vehicle
• Municipal Dump
• Newspaper Delivery
• Package Delivery
• Pick-up and Delivery
• Rapid Intervention
Vehicle (RIV)
• Rear Loader
• Recycling Truck
• Residential Pick-Up/Waste
• Rigging Truck
• Roll-Off
• Scrap Truck
• Semi-End Dump
• Sewer/Septic Vacuum
• Shuttle Bus
• Side Loader
• Snowplow/Snowblower
• Steel Hauling
• Tanker
• Tank Truck
• Tractors with Pole Trailers
• Tractor/Trailer with Jeeps
• Transfer Dump
• Transfer Vehicle
• Transit Bus
• Trolley
• Utility Truck
• Winch Truck

HEAVY SERVICE VEHICLES

HEAVY SERVICE (VOCATIONAL) WARRANTY INFORMATION

HEAVY SERVICE TYPICALLY IS
• On/Off road vocations (10% or more off-road) OR
• Moderate to frequent starts/stops typically more than three (3) stops per mile

2.87 WARRANTY - MODEL YEAR 2021 VEHICLES

INDUSTRIAL AND OFF-HIGHWAY SERVICE

TYPICALLY IS
• Low mileage operation3
• Vehicles are not typically licensed for highway use
¹ ZF and WABCO branded components. 2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 Equivalent hours of service limit: 2,000 hours for all components.

INDUSTRIAL/OFF-HIGHWAY SERVICE WARRANTY INFORMATION
WABCO Components1
Air Management
Air Brake Valves
Air Compressors (ALL)2 2/Unl/P
Air Dryers (ALL)
Brake Actuation
Air/Hydraulic Actuators
2/Unl/P
Master Cylinders
Remote Actuators
Slave and Wheel Cylinders
Two Fluid Actuators
Brake Locks
Brake Locks (ALL)
Electric Brake Locks 2/Unl/P
Lever Locks
Braking Systems
ABS (Anti-Lock Braking System) Air 1/100/P&L
ABS (Anti-Lock Braking System) Hydraulic
Driveline Suspension Control
Clutch Controls
1/100/P&L
Leveling Valves
Electrohydraulics & Controls
Electronic Pedals
Electrohydraulic Brake Valves (EBV) 2/Unl/P
Pressure Switches
Hydraulic Braking Solutions
Accumulator Charging Valves
Hydraulic Throttle Controls and Switches 2/Unl/P
Modulating Brake Valves
Wheel End Solutions
EasyFit™ Slack Adjuster 2/200/P
Caliper Disc Brakes 2/Unl/P
MAXXUS™ Air Disc Brake 1/Unl/P&L
Multiple Disc Brakes 2/Unl/P
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 22, 19 and 17 Air Disc Brake 1/Unl/P&L
TRISTOP™ D Actuator w/ IBV 3/Unl/P
TRISTOP™ D Actuator 2/200/P
UNISTOP™ Actuator 1/100/P
Market Common Application Types
Agriculture
Fertilizer Spreader, Tractor, Heavy Duty Ag
Trailers, Harvester, Sprayer, Skid Loader, Silage
Bagger, Slurry Wagons, Grain Cart
Airport Support
Pushback Tractor, Towing Tugs, Aircraft Tow
Tractor, Refueling Trucks, Food Service Trucks,
Baggage Tractors, De-Icing Equipment,
Runway Clearing Equipment
Construction
All-Terrain Crane, Rough Terrain Crane,
Excavator, Compactor, Wheel Loader, Road
Roller, Motor Grader, Articulated Dump Truck,
Rubber Tire Road Roller, Backhoe Loaders,
Haul Trucks, Scraper Rough Terrain Forklifts,
Trenchers, Drills
Forestry Logging Forwarder, Kidder, Loaders, Yard
Forklifts, Harvesters Fellers
Material Handling
Port Tractor, Rail Yard Spotter, Stevedoring
Tractor, Trailer Spotter, Yard Jockey, Scissor
Lift, Straddle Carrier, Manlift, Forklift, Boom Lift
Telebandlers, Aerial Work Platforms
Mining
Specialized Mining, Excavator, Haul Truck,
Underground Loader, Service Trucks, Wheel
Loaders, Scrapers, Load Haul Dumps,
Personnel Transports, Bolters, Scalers
Municipal
Street Sweeper, Utility Tractor, Utility Trucks,
Tree Trimmers, Dump Trucks, Tow Trucks, Flat
Bed Trucks, Winch Applications
Oil & Gas
Fracturing Trailer, Injecter Heads, Top Drives,
Jack/Lift Boats, Wireline Trucks, Load-On /
Load-Off
Rail
Railcar Mover, Track Layers, Grinders, Platform
Crane, Locomotive Railcars, Ballast Equipment,
Winch Applications

2.88 ABS, ELECTRONIC STABILITY CONTROL (ESC),
ROLL STABILITY CONTROL (RSC), OPTIRIDE®,
ONGUARD® AND ONLANE®, COLLECTIVELY
“ELECTRONICS”
Failure of electronic components due to overvoltage
condition, improper grounding, electrostatic discharge
(ESD), improper shielding, electromagnetic interference (EMI), or other wiring or installation issues. Malfunctions and failure codes caused by other electronic subsystem failures (data bus, engine, transmission, dashboard, etc.)

HYDRAULIC COMPONENTS
For certain components, brake fluid DOT3 or DOT4 is
used as the operating medium. Use of any other fluid will void all warranties associated with that component. For hydraulic braking applications the brake fluid is considered a maintenance item. Maintenance intervals are listed in TB1367.

COVERAGE LIMITATIONS

PRODUCT DESCRIPTION

ALL PRODUCTS
Any claim beyond 60 days from date of repair will not be accepted or honored under this warranty program.

Products purchased on an incomplete vehicle (glider) are limited to one year, 1/Unl/P.

For vehicles that operate full- or part-time outside of the United States and Canada, a 1-Year/Unlimited Miles parts only (1/Unl/P) will apply.

TOOLBOX PLUS™ DIAGNOSTIC SOFTWARE
Proper diagnostics of WABCO Electronics may require the latest version of TOOLBOX PLUS™. Additional labor due
to use of an outdated version of TOOLBOX™ software
and/or the time to purchase or install the latest version of TOOLBOX PLUS™ are not covered under product
warranty.

TERMS AND CONDITIONS

COVERAGE EXCLUSIONS

PRODUCT DESCRIPTION

ALL PRODUCTS
This Warranty shall not apply to the following, but not limited to: (1) damage to the product or its component
parts caused by incorrect use, installation, maintenance or repair, including without limitation (a) improper fit of mating components or brackets, damaged threads, cut, broken,
chafed, pinched or otherwise damaged wiring (sensors,
harnesses and connectors), (b) sensors damaged during
removal when seized in block, or associated with sensor adjustments/ alignments, and (c) damage resulting from the use or installation of non-genuine WABCO components or
materials; (2) damage to the product, its component parts, or diminished product or component part performance due to incorrect operation, deviation from approved conditions or misapplication; (3) any unauthorized disassembly of the product or its component parts including without limitation (a) obliterated, defaced or missing WABCO or WABCO
name plate, serial numbers or label identifying the device as a ZF product or WABCO component, (b) changes to sealed
adjusting screws, and (c) opening or attempted repair of non-serviceable components; (4) malfunction
of the component due to internal contamination of the
vehicle system including without limitation (a) water and other contamination damage that is due to the use of a
non-genuine air dryer cartridge or (b) valve failures due to contamination in air system, (5) complaints associated
with noise, (6) damage resulting from corrosion (including oxidation of electrical devices and connections).

AIR DRYERS
Mounting brackets (see vehicle OEM). Desiccant cartridge housing only.

AIR SYSTEM COMPONENTS
Normal wear items; Gladhand seals, dash valve knobs,
valve actuation handles, treadles, pedals.

2.89 WARRANTY - MODEL YEAR 2021 VEHICLES
(1) What is Covered by this Commercial Warranty?
ZF CV Systems North America LLC and its North American
subsidiaries and affiliates (ZF) warrant to the owner (“Owner”) that the components listed in this publication, which have been installed by an Original Equipment Manufacturer (“OEM”) as original equipment will be free from defects in material and workmanship. This warranty coverage begins from the original in-service date to the limits provided and runs concurrently with any warranties provided by OEMs and/or any distribution agreements and/or any service contracts that cover the components listed in this publication, if any. If the components listed in this publication are covered by an OEM warranty and/or service contract, then the OEM’s warranty and/ or service contract shall supersede ZF’s warranty and Owner shall comply with all OEM’s warranty and/or service contract requirements for claims under such OEM’s warranty and/or service contract until those agreements expire.

Once those agreements expire and provided the ZF warranty has not expired under the terms stated above, the ZF warranty will be in effect until its expiration date.

Warranty coverage ends at the expiration of the applicable time period from the date of vehicle purchase by the first Owner, or, the applicable mileage limitation, whichever occurs first. Duration of coverage varies by component and vocation as detailed previously in this publication.

Some components are warranted for parts only and the Owner must pay any labor costs associated with the repair or replacement of the component. Other components are warranted for both parts and reasonable labor to repair or replace the subject component.

Additional diagnostic time due to use of an outdated version of TOOLBOX™, time to purchase or install latest version of TOOLBOX™ are the responsibility of the authorized ZF distributor networks and are not covered under product warranty. Components installed as replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty. (2) Designation of Vocational Use Required. To obtain warranty coverage, each Owner must notify ZF through the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the WABCO components have been incorporated prior to the vehicle inservice date. This notification may be accomplished by registering the vehicle through your OEM new truck and/or trailer dealer or with ZF directly. Failure to notify ZF of (I) the intended vocational use of the vehicle or (II) a change in vocational use from that which was originally designated, will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial inservice date. A second Owner and each subsequent Owner must also notify ZF as to the intended vocational use of the vehicle. This notification can be sent directly to ZF or through
the OEM new truck and/or trailer dealer. The duration and mileage coverage of this warranty cannot exceed the coverage extended to the first Owner after his or her initial designation of vocational use. Coverage under ZF’s warranty requires that the application of products be properly approved pursuant to OEM and ZF, approvals. (3) What is the Cost of this Warranty? There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty? In addition to the items listed on "Coverage Exclusions," this warranty does not cover normal wear and tear, or service items; nor does it cover a component that fails, malfunctions or is damaged as a result of (a) improper handling, storage, installation, adjustment, repair or modification including the use of unauthorized attachments or changes or modification in the vehicle’s configuration, usage, or vocation from that which was originally approved by ZF, (b) accident, fire or other casualty, natural disaster, road debris, negligence, misuse, abuse, or improper use (including loading beyond the specified maximum vehicle weight or altering engine power settings to exceed the brake system capacity), or (c) improper or insufficient maintenance (including deviation from maintenance intervals, approved lubricants, or lube levels). This warranty does not cover any component or part that is not sold by ZF. (5) To obtain service. If the owner discovers within the applicable coverage period a defect in material or workmanship, the Owner must promptly give notice to either ZF or the dealer from which the vehicle was purchased. To obtain service, the vehicle must be taken to any participating OEM dealer or ZF distributor networks' servicer. The dealer or ZF authorized servicer will inspect the vehicle and contact ZF for an evaluation of the claim. When authorized by ZF, the dealer or ZF authorized servicer will repair or replace during the term of this warranty any defective WABCO component covered by this warranty. (6) Disclaimer of Warranty and Limitation of remedies. TO THE MAXIMUM

EXTENT PERMITTED BY LAW, THE LIMITED WARRANTY SET

FORTH HEREIN IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED, ARISING BY OPERATION OF

LAW OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY

IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE AND/OR WARRANTY FOR HIDDEN OR

LATENT DEFECTS, AND IN NO EVENT WILL ZF OR ANY OF ITS

AFFILIATES BE LIABLE FOR DIRECT, INDIRECT, INCIDENTAL,

PROGRESSIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES OF ANY
KIND.

TERMS AND CONDITIONS

2.90 (7) Legal action. Any legal action or claim arising from or related to this Warranty, in contract or otherwise, must be commenced within one year from the accrual of that cause of action, or be barred forever. Any dispute arising in connection with this agreement shall be governed by and construed according to the laws of the State of Michigan and be brought, heard and determined exclusively in either the Circuit Court for the County of Oakland, State of Michigan or the United States District Court for the Eastern District of Michigan. The parties stipulate that the referenced venues are convenient.
(8) Remedy. The exclusive remedy under this warranty shall be the repair or replacement of the defective component at ZF's option. ZF reserves the right to require that all applicable covered components are available and/or returned to ZF for review
and evaluation. THE MAXIMUM LIABILITY, IF ANY, OF ZF FOR ALL

DAMAGES, INCLUDING WITHOUT LIMITATION CONTRACT

DAMAGES, BREACH OF WARRANTY, NEGLIGENCE, STRICT

LIABILITY, OR OTHER TORT, IS LIMITED TO AN AMOUNT NOT TO EXCEED THE PURCHASE PRICE OF THE PRODUCT and where
indicated in the product and application warranty information above, the inclusion of labor is limited to the standard repair time. THE

PARTIES ACKNOWLEDGE AND AGREE THAT THE LIMITATION

OF DAMAGES PROVISION SET FORTH IN THIS PARAGRAPH

SURVIVES BETWEEN THE ORIGINAL END USER AND ZF EVEN IF

THE EXCLUSIVE REMEDY SET FORTH ABOVE IS DEEMED TO FAIL
OF ITS ESSENTIAL PURPOSE. ZF may change the design or make improvements to its Products without incurring any warranty obligation for previously manufactured Product .
(9) Entire Agreement. This is the entire agreement between ZF and the Owner about warranty and no, ZF employee, or dealer is authorized to make any additional warranty on behalf of ZF unless in writing and signed by an authorized representative of ZF.

2.91 About ZF Friedrichshafen AG
ZF is a global technology company and supplies systems for passenger cars, commercial vehicles and industrial technology, enabling the next generation of mobility. ZF allows vehicles to see, think and act. In the four technology domains Vehicle Motion Control, Integrated Safety, Automated Driving, and Electric Mobility, ZF offers comprehensive solutions for established vehicle manufacturers and newly emerging transport and mobility service providers. ZF electrifies different kinds of vehicles. With its products, the company contributes to reducing emissions and protecting the climate.

ZF, which acquired WABCO Holdings Inc. on May 29, 2020, now has 160,000 employees worldwide with approximately 260 locations in 41 countries. In 2019, the two then-independent companies achieved sales of €36.5 billion (ZF) and $3.4 billion (WABCO). For more information, visit: www.wabco-na.com
© 2021 ZF CV Systems North America LLC - All rights reserved - SP1375 / 2.2021 For further product details contact your distributor or the WABCO Customer Care Center at 855-228-3203.

2.92 Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0012

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This warranty applies only to the cab tubular support and mounting structures and other structural components of the cab of the vehicle model, as identified in the Pierce
specifications for the Fire and Rescue Apparatus.

This warranty does not apply to damage caused by corrosion.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:

Ten (10) Year Structural Integrity
Custom Cab
Ten (10) Years
- or -
100,000 Miles
Warranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

The Pierce Custom Cab shall be free from structural failures caused by defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

2.93 4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

Fire and Rescue Apparatus
Coverage:

Ten (10) Year Pro-Rated Paint and Corrosion
Cab
Ten (10) Years Warranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

Exterior surfaces of the cab painted by Pierce shall be free from blistering, peeling, corrosion or any other adhesion defect caused by defective manufacturing methods or paint material selection.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0055

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty is applicable to the vehicle in the following percentage costs of warranty repair, if any:

Topcoat Durability & Appearance: Gloss, Color Retention & Cracking
0-72 months 100%
73-96 months 50%
97-120 months 25%
Integrity of Coating System: Adhesion, Blistering/Bubbling 0-36 months 100%
37-84 months 50%
85-120 months 25%
Corrosion: Dissimilar Metal and Crevice
0-36 months 100%
37-48 months 50%
49-72 months 25%
73-120 months 10%
Corrosion Perforation
0-120 months 100%
This limited warranty applies only to exterior paint. Paint on the vehicle's interior is warranted only under the Pierce Basic One Year Limited Warranty.

Items not covered by this warranty include:
(a) Damage from lack of maintenance and cleaning (proper cleaning and maintenance procedures are detailed in the Pierce operation and maintenance manual).
(b) UV paint fade.
(c) Any cab not manufactured by Pierce.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

2.94 Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 1/11/2011 WA0188

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty does not apply to related wire
harnesses, cables, and connectors, which are covered by the Pierce one (1) year basic apparatus limited warranty.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:
54 Months Material and Workmanship
Camera System
Fifty - Four (54) months Warranty Period
Ends After:

Warranty Begins: The date of delivery.

This limited warranty covers repairs to correct any defect related to materials or workmanship of the Sharpvision
camera system installed on the apparatus occuring during the warranty period.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

2.95 Fire and Rescue Apparatus
Coverage:

Ten (10) Year Material and Workmanship
Pierce 12V LED Strip Light
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

This limited warranty covers repairs to correct any defect related to materials or workmanship of the Pierce 12V LED strip lights installed on the apparatus occuring during the warranty period.

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty does not apply to related wire
harnesses, cables, and connectors, which are covered by the Pierce one (1) year basic apparatus limited warranty.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Ten (10) Year Warranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 7/5/2011 WA0203
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

2.96 NEW PRODUCT WARRANTY

PARTICIPATING OEM SALES

DISTRIBUTOR SALES

LIMITED WARRANTY ON NEW ALLISON AUTOMATIC TRANSMISSIONS

USED IN EMERGENCY VEHICLE APPLICATIONS
Allison Transmission will provide for repairs or replacement, at its option, during the warranty period of each new Allison transmission listed below that is installed in an Emergency Vehicle in accordance with the following terms, conditions, and limitations.

WHAT IS COVERED
 WARRANTY APPLIES — This warranty is for new Allison transmission models listed below installed in an Emergency Vehicle and is provided to the original and any subsequent owner(s) of the vehicle during the warranty period.  REPAIRS COVERED — The warranty covers repairs or replacement, at Allison Transmission’s option, to correct any transmission malfunction resulting from defects in material or workmanship occurring during the warranty period. Needed repairs or replacements will be performed using the method Allison Transmission determines most appropriate under the circumstances.  TOWING — Towing is covered to the nearest Allison Transmission Distributor or authorized Dealer only when necessary to prevent further damage to your transmission.
 PAYMENT TERMS — Warranty repairs, including parts and labor, will be covered per the schedule shown in the chart contained in section “APPLICABLE MODELS, WARRANTY LIMITATIONS, AND ADJUSTMENT SCHEDULE.”  OBTAINING REPAIRS — To obtain warranty repairs, take the vehicle to any Allison Transmission Distributor or authorized Dealer within a reasonable amount of time and request the needed repairs. A reasonable amount of time must be allowed for the Distributor or Dealer to perform necessary repairs.
 TRANSMISSION REMOVAL AND REINSTALLATION — Labor costs for the removal and re-installation of the transmission, when necessary to make a warranty repair, are covered by this warranty.  WARRANTY PERIOD — The warranty period for all coverages shall begin on the date the transmission is delivered to the first retail purchaser, with the following exception:

Demonstration Service - A transmission in a new truck or bus may be demonstrated to a total of 5000 miles (8000 kilometers).

If the vehicle is within this limit when sold to a retail purchaser, the warranty start date is the date of purchase. Normal warranty services are applicable to the demonstrating Dealer. Should the truck or bus be sold to a retail purchaser after these limits are reached, the warranty period will begin on the date the vehicle was first placed in demonstration service and the purchaser will be entitled to the remaining warranty.

APPLICABLE MODELS, WARRANTY LIMITATIONS, AND ADJUSTMENT SCHEDULE

WARRANTY LIMITATIONS
(Whichever occurs first)

ADJUSTMENT CHARGE TO BE

APPLICABLE PAID BY THE CUSTOMER
MODELS
Months
Transmission Miles
Or Kilometers Parts Labor
MT, MD
3000, 3200, 3500, 3700 0–24 No Limit No Charge No Charge HT with Hydraulic Controls 0–24 No Limit No Charge No Charge AT, 1000 Series, 2000 Series,
2400 Series 0–36 No Limit No Charge No Charge
HT with Electronic Controls 0–60 No Limit No Charge No Charge HD
1000 EVS, 2100 EVS, 2200 EVS
2350 EVS, 2500 EVS, 2550 EVS,
3000 EVS, 3500 EVS, 4000,
4000 EVS, 4500, 4500 EVS, 4700,
4700 EVS, 4800, 4800 EVS
0–60 No Limit No Charge No Charge

Page 1 of 2 ends