Cities Index.
Agenda packet

Santa Cruz City Council
August 27, 2024

Document
Agenda packet
Meeting
August 27, 2024
Body
Santa Cruz City Council
Pages
54
Original file
115.2 MB
Text extracted from the city's file for reading and search. Open the original on ecm.cityofsantacruz.com. That file is the official record.

CITY OF SANTA CRUZ
809 Center Street
Santa Cruz, California 95060

CITY COUNCIL AGENDA
Regular Meeting - August 27, 2024
Updated August 23, 2024 – Item 23
Updated August 26, 2024 – Item 26
12:30 P.M. CLOSED SESSION, ZOOM/COURTYARD CONFERENCE ROOM 1:30 P.M. ORAL COMMUNICATIONS, CONSENT, CONSENT PUBLIC HEARINGS, AND

GENERAL BUSINESS, ZOOM/COUNCIL CHAMBERS
The meeting may be viewed remotely, using any of the following sources:
 Click on Zoom link (no time delay): https://zoom.us/j/94684401344  Online at http://www.cityofsantacruz.com/government/city-council/council-meetings  Online at Watch – Community Television of Santa Cruz County  Comcast Channel 25
Or: Call any of the numbers below. If one is busy, try the next one.  1-833-548-0276 (Toll Free)
 1-833-548-0282 (Toll Free)
 1-877-853-5247 (Toll Free)
 1-669-900-9128
 Enter the meeting ID number: 946 8440 1344
 When prompted for a Participant ID, press #.
 Press *9 on your phone to “raise your hand” when the Mayor calls for public comment.  It will be your turn to speak when the Mayor calls on you. Press *6 to unmute yourself. The timer will then be set.

Correspondence to be included in the agenda packet must be received by 5:00 pm on Monday, August 26th
PLEASE NOTE:
 Council may take a break(s) as needed.
 Requests for extra speaking time on items other than Oral Communications must be made by 5:00 p.m. on Sunday, August 25th by emailing the Mayor and the City Clerk. Approval will be confirmed via email.
[email protected] [email protected]
August 27, 2024 City Council 2
The City of Santa Cruz does not discriminate against persons with disabilities. Out of consideration for people with chemical sensitivities we ask that you attend fragrance free. Upon request, the agenda can be provided in a format to accommodate special needs. Additionally, if you wish to attend this public meeting and will require assistance such as an interpreter for American Sign Language, Spanish, or other special equipment, please call the City Clerk’s Department at 420-5030 at least five days in advance so that we can arrange for such special assistance, or email [email protected]. The Cal-Relay system number: 1-800-735-2922.

Si desea asistir a esta reunión pública y necesita ayuda - como un intérprete de lenguaje de señas americano, español u otro equipo especial - favor de llamar al Departamento de la Secretaría de la Ciudad al 420-5030 al menos cinco días antes para que podamos coordinar dicha asistencia especial o envié un correo electrónico a [email protected]. El número del sistema Cal-Relay es: 1-800-735-2922.

Agenda and Agenda Packet Materials: The City Council agenda and the complete agenda packet containing public records, which are not exempt from disclosure pursuant to the California Public Records Act, are available for review on the City’s website:
www.cityofsantacruz.com/government/city-council-meetings and at the Office of the City Clerk located at 809 Center Street, Room 8, Santa Cruz, California, during normal business hours.

Agenda Materials Submitted after Publication of the Agenda Packet: Pursuant to Government Code §54957.5, public records related to an open session agenda item submitted after distribution of the agenda packet are available at the same time they are distributed or made available to the legislative body on the City’s website at: www.cityofsantacruz.com/government/city-council-meetings and are also available for public inspection at the Office of the City Clerk, 809 Center Street Room 8, Santa Cruz, California, during normal business hours, and at the Council meeting.

Need more information? Contact the City Clerk’s office at 831-420-5030. 12:30 PM
Statements of Disqualification
Closed Session

1. Conference with Legal Counsel – Liability Claims (Government Code §54956.95)
1) Claimant: David Santana Mata
2) Claimant: State Farm Insurance
3) Claimant: Efrain and Maritza Ayala Talamantes Haro
4) Claimant: Frances S. Lopez
Claims against the City of Santa Cruz
August 27, 2024 City Council 3
Closed Session (continued)

2. Real Property Negotiations (Government Code §54956.8) Property: 877 Cedar Street
APN: 005-951-01
Owner: Ecology Action
City Negotiator: Bonnie Lipscomb
Negotiating Parties: City of Santa Cruz and Ecology Action Under Negotiation: Price, terms of payment, or both

3. Conference with Legal Counsel – Anticipated Litigation (Government Code §54956.9(d)(2))
Significant exposure to litigation (one potential case to be discussed)

4. Conference with Legal Counsel – Anticipated Litigation (Government Code §54956.9(d)(4))
Initiation of litigation (one potential case to be discussed) August 27, 2024 City Council 4
City Council
1:30 PM
Call to Order
Roll Call
Oral Communications Announcement – Members of the public may address Council on matters not on the agenda, but within the jurisdiction of the Council. 30 minutes is allocated for Oral Communications. No extra time for groups will be granted.

Oral Communications
Presentations

5. Mayoral Proclamation Declaring September, 2024, as Ovarian Cancer Awareness Month

6. Oral Health Access 2024—2028 Strategic Plan
Presiding Officer's Announcements
Statements of Disqualification
Additions and Deletions
City Attorney Report on Closed Session
Council Meeting Calendar

7. The City Council will review the meeting calendar attached to the agenda and revise it as necessary.

August 27, 2024 City Council 5
Consent Agenda

8. Minutes of the August 13, 2024 City Council Meeting (CC) Motion to approve as submitted.

9. 2024 A City Like Me: Santa Cruz Report (CM)
Motion to accept the 2024 A City Like Me report as submitted.

10. Endorsement of California Senate Bill 867 (CN)
Motion to direct the Mayor to send a letter of endorsement in support of California Senate Bill 867.

11. Approve Purchase of Pierce Enforcer Pumper Fire Engine and Lease Agreement with PNC Equipment Finance (FD)
Motion to:
1) Award a contract for the purchase of a Pierce Enforcer Pumper Fire Engine (Apparatus) to Golden State Fire Apparatus in the amount of $1,029,503.26.
2) Adopt a resolution approving a lease agreement with PNC Equipment Finance to prepay for the purchase and finance the Apparatus for the City with a 5.32% interest rate over three (3) years for a total cost of $1,140,934.14; and authorizing the City Manager to execute the agreement and related documents in a form to be approved by the City Attorney.

August 27, 2024 City Council 6
Consent Agenda (continued)

12. First Amendment to the Agreement for Fire Protection and Emergency Response Services and First Amendment of Lease of the UCSC Fire Station (FD)
Motion to authorize the City Manager to execute the First Amendment to the Agreement for Fire Protection and Emergency Response Services (Service Agreement) and the First Amendment of Lease of the University of California Santa Cruz (UCSC) Fire Station (Lease) between the City of Santa Cruz (City) and the Regents of the University of California, on behalf of its Santa Cruz Campus, extending the term for one (1) year with minor modifications.

13. Council Policy 5.19 for Stipend for Advisory Body Members (FN) Motion to:
1) Adopt a resolution approving Council Policy 5.19 – Stipend for Advisory Body Members;
2) Direct staff to prepare amendments to Ordinance 1440 and Chapter

18.41 of the Municipal Code; and
3) Direct staff to create a communication and training plan to promote the new policy.

14. Liability Claims Filed Against the City of Santa Cruz (FN) Motion to reject the liability claims of 1) David Santana Mata, 2) State Farm Insurance, and 3) Efrain and Maritza Ayala Talamantes Haro; based on staff recommendation.

August 27, 2024 City Council 7
Consent Agenda (continued)

15. Award Contract for Disaster Cost Recovery Services (FN) Motion to:
1) Award a three-year contract for Disaster Cost Recovery Services to Integrated Solutions Consulting (ISC) beginning on August 27, 2024, and ending June 30, 2025, 2026, and 2027 (with an option for an additional two years for Fiscal Years ending June 30, 2028, and 2029); 2) Authorize the City Manager to execute an agreement in a form approved by the City Attorney with ISC; and
3) Authorize the Finance Director to execute any amendments that may be needed for new emergencies during the course of the contract.

16. Microsoft SharePoint Implementation and Configuration Services (IT) Motion to:
1) Accept the change order from AdaptivEdge, LLC for additional Microsoft SharePoint Online implementation and configuration services in the amount of $31,400.00, for a total contract amount of $127,400.00.

The IT Director is authorized to execute further change orders within the approved project budget; and
2) Authorize the City Manager to execute additional contracts with AdaptivEdge, LLC for Microsoft SharePoint Online implementation and configuration services in a form approved by the City Attorney. The IT Director is authorized to execute change orders within the approved project budget.

August 27, 2024 City Council 8
Consent Agenda (continued)

17. Downtown Recovery – Phase IV – Authorization to Award Bid for Downtown Site Furnishings Painting to H.B. Restoration Inc. in the Amount of $112,550.00 (PR)
Motion to authorize staff to award a contract for services in the amount of $112,550.00 to H.B. Restoration for the painting of existing site furnishings and kiosks, serving as the final component of the Downtown Recovery – Phase I-IV project (c302312). Per Resolution No. NS-27,563, the City Manager is hereby authorized and directed to execute the contract in a form approved by the City Attorney. The Parks and Recreation Director, Economic Development and Housing Director, and Public Works Director are authorized to execute change orders within approved budgets.

18. Award Contract for Purchase of Three Refuse Trucks (PW) Motion to award a contract for the purchase of one roll-off and two split rear loader vehicles from TEC of California (Oakland, CA) in the amount of $1,390,000.

19. Resource Recovery Facility North Canyon Paving Project (m400020) – Authorization to Advertise for Bids and Award Contract (PW) Motion to approve the plans and specifications for the Resource Recovery Facility North Canyon Paving Project (m400020) and authorize staff to advertise for bids and award the contract. The City Manager is hereby authorized and directed to execute an agreement in a form approved by the City Attorney. The Director of Public Works is authorized to execute change orders within the approved project budget.

20. Fisheries Monitoring Support – Award of Professional Services Contract to Confluence Restoration (WT)
Motion authorizing the City Manager to execute an agreement in a form approved by the City Attorney with Confluence Restoration (Santa Cruz, CA) for ongoing fisheries biology support of the City of Santa Cruz's Habitat Conservation Plan development and Incidental Take Permitting in the amount of $127,860.00 and to authorize the Water Director to execute up to three annual agreement renewals.

August 27, 2024 City Council 9
Consent Agenda (continued)

21. Acceptance and Budgeting of Grant Funding for Brackney Landslide Area Pipeline Risk Reduction Project - Budget Adjustment (WT) Motion to adopt a resolution authorizing acceptance of additional Hazard Mitigation Grant Program funding in the amount of $3,858,079 and amending the Water Department FY 2025 revenue budget for the Capital Investment Program (c702002), Brackney Landslide Area Pipeline Risk Reduction Project, accordingly.

End Consent Agenda
Consent Public Hearings

22. 2nd Reading and Final Adoption of Ordinance No. 2024-11 which Amends Chapter 24.12 of the Santa Cruz Municipal Code Related to Historic Variations in Response to Action by the California Coastal Commission (PL)
Motion to adopt Ordinance No. 2024-11 finding that the project is exempt under the California Environmental Quality Act (CEQA) and amending parts of Chapter 24.12 of the Santa Cruz Municipal Code (SCMC) related to Historic Variations in response to action by the California Coastal Commission.

Item 23 was updated to amend the recommendation and add the draft resolution.

23. 2nd Reading and Final Adoption of Ordinance No. 2024-12 Amending Municipal Code Chapter 24.10 and Sections 24.12.190, 24.12.290, and

24.12.1108 and Adding New Sections 24.10.2342 and 24.12.191 to Streamline Permitting and Establish Standards for Private Property Outdoor Seating Associated with Eating and/or Drinking Establishments (PL/EDH)
Motion to:
1) Adopt Ordinance No. 2024-12 amending Santa Cruz Municipal Code Chapter 24.10 and Sections 24.12.190, 24.12.290, and 24.12.1108, and adding new Sections 24.10.2342 and 24.12.191 to streamline permitting and establish standards for private property outdoor seating associated with eating and/or drinking establishments.
2) Adopt a resolution authorizing the City Manager to submit the proposed Title 24 amendments to the California Coastal Commission for final certification.

August 27, 2024 City Council 10
Consent Public Hearings (continued)

24. 2nd Reading and Final Adoption of Ordinance No. 2024-13 Amending Uncodified Ordinance No. 2020-27 Extending Temporary Use of Certain Adjacent Public Street and Outdoor Areas for Eligible Businesses that Extends the Temporary Period for Commercial Use on Private Property from May 31, 2025, to July 1, 2026 (PL/EDH)
Motion to adopt Ordinance No. 2024-13 amending uncodified Ordinance No. 2020-27 extending temporary use of certain adjacent public street and outdoor areas for eligible businesses that extends the temporary period for commercial use on private property from May 31, 2025, to July 1, 2026.

General Business

25. Harvey West Pool Update and Amending the FY 2025 Budget and Appropriation of Funds for Harvey West Pool - Budget Adjustment (PR) Motion to:
1) Receive an update on the Harvey West Pool operational plan; and 2) Adopt a resolution to amend the Fiscal Year 2025 budget and appropriate funds in the amount of $400,000 from the fund balance of the General Fund, to be allocated to Parks and Recreation for expenses to run and resource a Harvey West Pool hybrid operational model.

August 27, 2024 City Council 11
General Business (continued)
Item 26 was updated to amend the recommendation, agenda report, and the draft resolution.

26. No-Parking Street Sweeping Pilot Program (PW)
Motion to:
1) Adopt a resolution to approve parking restrictions for the pilot street sweeping program in Zones 1-4 during posted hours and direct the City Manager or designee to implement the 1-year pilot program; 2) Provide support and recommend parking restrictions for the pilot street sweeping program in Zones 5-6 and adopt a resolution to approve parking restrictions for the pilot street sweeping program in Zones 5-6 during posted hours and direct the City Manager or designee to implement the 1-year pilot program upon approval of the Coastal Development Permit. Zones 5-6 are located within the Coastal Zone, the Coastal Development Permit will be subject to a Coastal Commission appeal period following approval by the Council; and
3) Direct staff to return before the conclusion of the No-Parking Street Sweeping Pilot Program with findings and recommendations.

27. Ordinance Amending Chapter 2.40, Boards and Commissions, Related to the Membership Term Year for the Commission for the Prevention of Violence Against Women (CPVAW) (CC)
Introduce for publication an ordinance amending Chapter 2.40, Boards and Commissions, related to the membership term year for the Commission for the Prevention of Violence Against Women.

28. Award Professional Service Agreement to Intelligent Partnerships to Explore Feasibility of Community Workforce or Project Labor Agreements for City Capital Investment Projects (CN)
Motion to:
1) Award a professional services agreement to Intelligent Partnerships to conduct a feasibility study of the potential options and implications of adopting either a Community Work Force Agreement (CWA) or Project Labor Agreement (PLA); and
2) Authorize the City Manager to execute said agreement in the form approved by the City Attorney. The Water and Public Works Directors are authorized to execute contract amendments within the approved budget.

August 27, 2024 City Council 12
General Business (continued)

29. Newell Creek Pipeline Replacement – Felton to Graham Hill Water Treatment Plant Project (c702105): Purchase of Real Property, Approval of Plans and Specifications, Authorization to Advertise for Bids and Award of Contract; Authorizing Approval of an SRF Financing Agreement, and Acceptance of Community Grant Program Funds and Amending Water Department FY 2025 Budget – Budget Adjustment (WT) Motion to:
1) Adopt a resolution authorizing and directing the City Manager to execute a purchase sale agreement between the City of Santa Cruz and Santa Cruz, Big Trees & Pacific Railway for the permanent easement on APN 066-211-03 for the Newell Creek Pipeline Replacement – Felton to Graham Hill Water Treatment Plant Project (c702105);
2) Adopt a resolution authorizing and directing the City Manager to execute a purchase sale agreement between the City of Santa Cruz and Santa Cruz, Big Trees & Pacific Railway for a permanent easement on APN 066-212-05;
3) Approve the plans and specifications for the Newell Creek Pipeline Replacement – Felton to Graham Hill Water Treatment Plant Project (c702105) and authorize staff to advertise for bids at
https://procurement.opengov.com/portal/santacruzca. The City Manager is hereby authorized and directed to execute the contract as authorized by Resolution No. NS-27,563; and authorize the Water Director to execute change orders within the approved project budget; 4) Adopt a resolution authorizing approval of a financing agreement in an amount not to exceed $41,352,000 with the California State Water Resources Control Board for the Newell Creek Pipeline Replacement – Felton to Graham Hill Water Treatment Plant Project (c702105); and 5) Adopt a resolution amending the FY 2025 budget to accept $959,752 in Community Grant Funds for the Newell Creek Pipeline Replacement – Felton to Graham Hill Water Treatment Plant Project (c702105).

Adjournment
August 27, 2024 City Council 13

INFORMATION ITEMS PREVIOUSLY DISTRIBUTED TO CITY COUNCILMEMBERS None issued.

MAYOR'S PROCLAMATIONS
ADDENDUM TO CITY COUNCIL AGENDA – AUGUST 27, 2024

30. Proclaiming July 2, 2024 as “Dave Rosell Retirement Day” and encouraging all his coworkers and citizens to join in expressing heartfelt appreciation for his eleven years of dedicated and exemplary service and numerous contributions to the Santa Cruz Police Department and the City of Santa Cruz and wishing him well in his retirement.

31. Proclaiming the month of September 2024 as “Ovarian Cancer Awareness Month” and encouraging all citizens to join in recognizing and supporting the patients, families, and professionals leading the fight against ovarian cancer.

Advisory Body Appointments
The following position is currently vacant. Council will make the appointment at a future meeting.

County Latino Affairs Commission One opening – at-large nomination August 27, 2024 City Council 14
Public Hearing
If, in the future, you wish to challenge in court any of the matters on this agenda for which a public hearing is to be conducted, you may be limited to raising only those issues which you (or someone else) raised orally at the public hearing or in written correspondence received by the City at or before the hearing.

Any person seeking to challenge a City Council decision made as a result of a proceeding in which, by law, a hearing is required to be given, evidence is required to be taken, and the discretion in the determination of facts is vested in the City Council, shall be required to commence that action either 60 days or 90 days following the date on which the decision becomes final as provided in Code of Civil Procedure Section 1094.6 Please refer to code of Civil Procedure 1094.6 to determine how to calculate when a decision becomes “final.” The 60- day rule applies to all public hearings conducted pursuant to the City’s Zoning Ordinance, Title 24, Santa Cruz Municipal Code. The 90-day rule applies to all other public hearings.
2024-2028
Strategic Plan EVERYONE

DESERVES

A HEALTHY
SMILE!
OHA Co-Chairs:
• David Brody, First 5 Santa Cruz County • Sheree Storm, Dientes Community Dental Care

6.1 Our OHA Journey
2 2015
Needs
Assessment
2016
16 OHA
Partners
Strategic
Plan
Summit
2017
Local
Oral
Health
Program
2018
Report
Card
2023
Senior
Grant
Dientes /
Salud
2024
24 OHA
Partners
Strategic
Plan
Summit
2021
Report
Card
Summit
2022
Needs
Assessment
Local
Oral
Health
Program
= Data Reports = OHA = Plans = Events = Funding
//

6.2 3
Members

6.3 After age 5, dramatic drop off
in going to the dentist
4 1-2 3-5 6-9 10-14 15-18 19-20 21-34 35-55 45-64 65-74 75+ % WHO VISITED THE DENTIST IN 2022
CA Santa Cruz County
61%
18%
Key
Finding
* Medi-Cal Dental Utilization in Santa Cruz County, CY2022 6.4 2024 – 2028
Strategic
Plan
5 INCREASE

ACCESS TO
DENTAL
CARE

6.5 GOAL 1
Expand
Prevention,
Treatment,
& Capacity
6 CHAMPIONS
Dr. Sepi Taghvaei
Dientes
Dr. Sung Sohn
Salud Para La Gente

6.6 GOAL 1
Increase Appointments
• Continue to ramp up post-pandemic
• Hire dentists, mid-level providers,
and support staff
• Prioritize access to comprehensive
dental care for special populations
74k
IN 2028
62k
IN 2022
7 6.7
GOAL 2
Collaborate
with
Schools
8 CHAMPIONS
Monica Nicholas
County Public Health,
Local Oral Health Program
Heather Thomsen
County Office of
Education
Claudia Martin
Salud Para La Gente 6.8
GOAL 2
Kinder
Oral Health
9 60%
IN 2028
61%
IN 2022
=
* Children aged 3-9
54%
47%
29%
18%
10–14 15–18 19–20 21–34
Young people with Medi-Cal going to the
Dentist
Tween / Teen
Oral Health
60%
IN 2028

6.9 GOAL 3
10 Focus on
Seniors CHAMPIONS
Laura Marcus
Dientes
Dr. Sung Sohn
Salud Para La Gente

6.10 GOAL 3
Seniors
Going to the Dentist
• Mobile dentistry where seniors are
• Promote transportation options
• Oral health education campaign
• Distribute hygiene kits
• Advocate for dental
to be a part
of Medicare
11 * Seniors 65+
40%
IN 2028
27%
IN 2022

6.11 GOAL 4
12 Medical
& Dental
Integration

6.12 GOAL 4
13 1) Pregnant People Going
to the Dentist
60%
IN 2028
47%
IN
2020
2) First Tooth First Birthday
60%
IN 2028
52%
IN
2022
3) Increase
Fluoride
Varnish
Applications
4) Increase
Education
and Access
to those with
Diabetes
Medical & Dental Integration

6.13 Thanks!
oralhealthscc.org
14 6.14

6.15 6.16

6.17 6.18

6.19 6.20
Meeting Type
Holiday
Jewish Holiday
Regular Meeting
Special Meeting (will be added as scheduled)
Study Session (will be added as scheduled)
Budget Hearing
DATE Location Meeting Type
September 2
Courtyard Conf. Room Closed Session - Closed to the Public Council Chambers Council Regular Meeting - Open to the Public Courtyard Conf. Room Closed Session - Closed to the Public Council Chambers Council Regular Meeting - Open to the Public October 2/3
Courtyard Conf. Room Closed Session - Closed to the Public Council Chambers Council Regular Meeting - Open to the Public October 11/12
Courtyard Conf. Room Closed Session - Closed to the Public Council Chambers Council Regular Meeting - Open to the Public November 11
Courtyard Conf. Room Closed Session - Closed to the Public Council Chambers Council Regular Meeting - Open to the Public November 28
November 29
Courtyard Conf. Room Closed Session - Closed to the Public Council Chambers Council Regular Meeting - Open to the Public December 25/26
December 25
City Council Meeting Calendar for 2024
December 10
City Hall Closure - Thanksgiving Day
City Hall Closure - Day After Thanksgiving Day
September 10
September 24
Please note: Meeting times are not final and are likely to change City Hall Closure - Labor Day
December 24 Meeting Cancelled - CITY COUNCIL DARK
City Hall Closure - Christmas Day
Rosh Hashanah (City observed - sundown to sundown)
November 19
October 8
October 22
City Hall Closure - Veteran's Day (observed)
Hanukkah (City observed - sundown to sundown)
Yom Kippur (City observed - sundown to sundown)

7.1 MINUTES ARE UNOFFICIAL UNTIL APPROVED BY COUNCIL
City of Santa Cruz
809 Center Street
Santa Cruz, California 95060

MINUTES OF A CITY COUNCIL MEETING
August 13, 2024
1:30 PM
Mayor Keeley opened the City Council Closed Session at 1:31 p.m. in a public meeting via Zoom and in Council Chambers, for the purpose of announcing the agenda, and receiving public testimony.

Roll Call

Present: Councilmembers Newsome, Brown, Watkins, Brunner, KalantariJohnson; Vice Mayor Golder; Mayor Keeley.

Absent: None.

Staff: City Manager M. Huffaker, City Attorney T. Condotti, Deputy City Clerk Administrator J. Wood, City Clerk Administrator B. Bush.

Statements of Disqualification – None.

Public Comment
Mayor Keeley opened the public comment period at 1:32 p.m. There were no speakers. Mayor Keeley closed the public comment period at 1:32 p.m., at which time the meeting was closed to the public and Council adjourned to the Courtyard Conference Room.

8.1 August 13, 2024 CITY COUNCIL MINUTES 6904
Closed Session

1. Conference with Legal Counsel – Liability Claims (Government Code §54956.95) 1) Claimant: Viet Huong Vo
2) Claimant: Geico Insurance Company
Claims against the City of Santa Cruz
Council received a status report, took up under agenda item 14, and no reportable action was taken.

2. Real Property Negotiations (Government Code §54956.8) Property: 37 Municipal Wharf
APN: 007-341-03
Owner: Stagnaro Fish Corporation (c/o Dino Stagnaro) dba Gilda’s City Negotiator: Bonnie Lipscomb
Negotiating Parties: City of Santa Cruz and Stagnaro Fish Corporation Under Negotiation: Price, terms of payment, or both
Council received a status report from the City Negotiator, gave direction, and no reportable action was taken.

3. Conference with Legal Counsel – Anticipated Litigation (Government Code §54956.9(d)(4))
Initiation of litigation (one potential case to be discussed) Council received a status report, gave direction, and took no reportable action.

4. Conference with Legal Counsel – Anticipated Litigation (Government Code §54956.9(d)(2))
Significant exposure to litigation (one potential case to be discussed) Council received a status report and took no reportable action.

8.2 August 13, 2024 CITY COUNCIL MINUTES 6905
City of Santa Cruz
809 Center Street
Santa Cruz, California 95060

MINUTES OF A CITY COUNCIL MEETING
August 13, 2024
3:15 PM
Call to Order – Mayor Keeley called the meeting to order at 3:16 p.m. in Council Chambers.

Roll Call

Present: Councilmembers Newsome, Brown, Watkins, Brunner, KalantariJohnson; Vice Mayor Golder; Mayor Keeley.

Absent: None.

Staff: City Manager M. Huffaker, City Attorney T. Condotti, Director of Planning and Community Development L. Butler, Director of Public Works N. Nguyen, Director of Parks and Recreation T. Elliot, Director of Water H. Luckenbach, Director of Economic Development B. Lipscomb, Director of Finance E. Cabell (via Zoom), Director of Information Technology K. Morgan (via Zoom), Deputy Assistant Manager L. Murphy (via Zoom), Chief of Police B. Escalante (via Zoom), Chief of Fire R.

Oatey (via Zoom), Senior Planner S. Neuse, Senior Planner C. Stanger, Economic Development Manager R. Unitt, Deputy City Clerk Administrator J. Wood, City Clerk Administrator B. Bush.

Oral Communications Announcement - The Mayor provided a brief announcement about Oral Communications.

Oral Communications
At 3:18 p.m. Mayor Keeley opened Oral Communications for members of the public who wished to speak regarding items not listed on the City Council agenda.

Laura Chatham read from a letter from the Mental Health Advisory Board to the Board of Supervisors regarding homelessness.

Unidentified person spoke regarding e-bike safety and lights not changing when he is on the road.

8.3 August 13, 2024 CITY COUNCIL MINUTES 6906
Oral Communications (continued)
Unidentified person spoke regarding the unexpected death of a previous Councilmember’s spouse, the AI-generated building the media published, and low-income housing.

Garrett spoke regarding electrification as discussed at a previous meeting, particularly historic building codes in contrast to what is being presently proposed, and feels Council is bordering on unconstitutional moving forward with electrification.

Unidentified person read from a letter from the Mental Health Advisory Board to the Board of Supervisors regarding homelessness.

Unidentified person read from a letter from the Mental Health Advisory Board to the Board of Supervisors regarding homelessness.

Unidentified person read from a letter from the Mental Health Advisory Board to the Board of Supervisors regarding homelessness.

Dora spoke regarding homeless encampment sweeps.

Greg Benson spoke regarding homeless encampment sweeps.

Troy Mason spoke regarding erecting a monument to honor the homeless population who have died.

Unidentified person spoke regarding homeless encampment sweeps and property storage.

James Ewing-Whitman spoke regarding monkey pox, national politics, $4 trillion loss on the stock market, the book The Great Taking by David Rogers Webb, and the dangers of taking testosterone.

Catherine Traverse spoke regarding the rent increases at the St. George Hotel.

Unidentified person spoke regarding homeless encampment sweeps.

At 3:48 p.m. Mayor Keeley closed Oral Communications.

8.4 August 13, 2024 CITY COUNCIL MINUTES 6907
Presiding Officer's Announcements – Mayor Keeley extended thanks on behalf of the City of Santa Cruz to Senator Laird, the Speaker, Assemblymembers Pellerin and Addis and the entire legislation delegation who were so helpful to get additional millions of dollars to assist with our local shelter efforts. He also expressed condolences to former Councilmember Richelle Noroyan with regard to the unexpected death of her spouse.

Statements of Disqualification – None.

Additions and Deletions – None.

City Attorney Report on Closed Session – See page 6904 for the report.

Council Meeting Calendar

5. The City Council reviewed and did not revise the meeting calendar attached to the agenda.

Consent Agenda
Councilmember Newsome made a comment on items 16, 17, 21, and 24.

Councilmember Brown made a comment on item 18.

Vice Mayor Golder made a comment on items 18, 21, and 27.

Councilmember Kalantari-Johnson made a comment on items 18, 21, 24, 26, and 27.

Councilmember Brunner made a comment on items 12 and 18.

Mayor Keeley opened the public comment period. The following people spoke:

Unidentified person spoke regarding items 7 and 18.

Unidentified person spoke regarding item 17.

Mayor Keeley closed the public comment period.

MOTION: Councilmember Watkins moved, seconded by Councilmember KalantariJohnson, to approve the Consent Agenda.

8.5 August 13, 2024 CITY COUNCIL MINUTES 6908
Consent Agenda (continued)
ACTION: The motion carried with the following vote.

AYES: Councilmembers Newsome, Brown (with the exception of item 18), Watkins, Brunner, Kalantari-Johnson; Vice Mayor Golder; Mayor Keeley.

NOES: Councilmember Brown (item 18).

ABSENT: None.

DISQUALIFIED: None.

6. Resolution Extending the Emergency Declarations in Connection with the 2022/2023 Winter Storms and 2023/2024 Winter Storms (CA/CM) Resolution No. NS-30,362 was adopted extending by sixty days the Local Emergency Declarations in connection with the 2022/2023 and 2023/2024 winter storms.

7. Minutes of the June 25, 2024 City Council Meeting (CC) Motion carried to approve as submitted.

8. Minutes of the August 6, 2024 City Council Study Session (CC) Motion carried to approve as submitted.

9. Resolution Amending the 2024 Council Meeting Calendar (CC) Resolution No. NS-30,363 was adopted amending the 2024 Council meeting calendar to cancel the November 12th and 26th regular meetings and add November 19th as a regular meeting, and rescinding Resolution No. NS-30,235.

10. Review and Amendment of the City’s Conflict of Interest Code (CC) Resolution No. NS-30,364 was adopted amending the current Conflict of Interest Code.

8.6 August 13, 2024 CITY COUNCIL MINUTES 6909
Consent Agenda (continued)

11. Federal Highways Administration Charging and Fueling Infrastructure Discretionary Grant Community Program. Authorization to Submit a Grant Application for the Monterey Bay Region Equitable EV Charging Project Grant (CM)
Resolution No. NS-30,365 was adopted authorizing the City Manager to apply for, accept, and appropriate funds from the Federal Highways Administration Charging and Fueling Infrastructure Discretionary Grant Community Program as lead and co-applicant for installation of publicly available level 2 and DC fast charging at City-owned facilities.

12. California Ocean Protection Council (OPC) Senate Bill (SB) 1 Grant Program:

Approval to Execute Grant Funds to Develop a Resilient Coast Santa Cruz 2.0:

Shoreline Adaptation Blueprint (CM)
Resolution No. NS-30,366 was adopted approving the execution of grant funds from the Ocean Protection Council under the SB 1 Grant Program funded through California's Greenhouse Gas Reduction Fund and General Fund to develop three Shoreline Adaptation Blueprints along the City of Santa Cruz’ coastline.

13. Criminal Justice Council of Santa Cruz County (CM)
Motion carried authorizing the City Manager to sign the third amendment to the Joint Exercise of Powers Agreement for the Criminal Justice Council (CJC) of Santa Cruz County to extend City of Santa Cruz participation for a one-year term through June 30, 2025.

14. Liability Claims Filed Against the City of Santa Cruz (FN) Motion carried to reject the liability claim of 1) Viet Huong Vo, and to return as late, the claim of 2) Geico Insurance Company, based on staff recommendation.

8.7 August 13, 2024 CITY COUNCIL MINUTES 6910
Consent Agenda (continued)

15. Professional Services Agreement for a Facilities Condition Assessment (PR) Motion carried to approve and authorize the City Manager to execute a Professional Services Agreement with Bureau Veritas Technical Assessments LLC, in a form approved by the City Attorney, for professional services not to exceed $150,000 over a two-year term. The Director of Parks and Recreation is authorized to execute contract amendments and change orders within the approved project budget (c302301).

16. Main Beach Public Restroom Renovation Project (c301913) – Notice of Completion (PR)
Motion carried to accept the work of CWS Construction Group, Inc. (Novato, CA) as completed per plans and specifications and authorize the filing of the Notice of Completion for the Main Beach Public Restroom Renovation Project (c301913)

17. 2024 Wharf Repair Project – 1st Amendment for Engineering Services and Budget Adjustment (PR)
Motion carried to:
 Approve and authorize the City Manager to execute a first amendment to the Professional Services Agreement with Moffatt & Nichol for Engineering Services in the amount of $80,300 for the 2024 Wharf Repair Project, in a form approved by the City Attorney. The Director of Parks and Recreation is authorized to execute contract amendments within the approved project budgets;
 Adopt Resolution No. NS-30,367 amending the FY 2024 budget to increase the revenue and expenditure budgets for the December 2023 Wharf Storm Damage Repair Project (e302402) by the amount of $2,069,371.51; and  Adopt Resolution No. NS-30,368 amending the FY 2024 budget to increase the revenue and expenditure budgets for the February 2024 Wharf Storm Damage Repair Project (e302403) by the amount of $1,481,324.93.

8.8 August 13, 2024 CITY COUNCIL MINUTES 6911
Consent Agenda (continued)

18. Pogonip Nature Loop Trail Encampment Clean-up Contract (PW/CM) Motion carried to approve refuse collection and encampment clean-up work in the Pogonip through a Single Source agreement with Kenny Robinson Construction in an amount not to exceed $140,000. The Public Works Director is authorized to execute change orders within the approved project budget.

19. Caterpillar 299D3 XE Compact Track Loader Purchase (PW) Motion carried to approve the purchase from the Refuse Fund of one (1) Caterpillar 299D3 XE Compact Track Loader, one (1) MB L160 S2 Crusher Bucket attachment, and one (1) Hydraulic Hammer attachment in the amount of $199,513.51 from Peterson Tractor Co. (San Leandro, CA).

20. 733 River St. Post-Demolition Paving (c102303) – Notice of Completion (PW) Motion carried to accept the work of Atlantis Paving & Grading (Scotts Valley, CA) as completed per the plans and specifications and authorize filing the Notice of Completion for the 733 River Street Post-Demolition Paving Project and authorizing the Public Works Director to sign the Notice of Completion as the Owner’s Authorized Agent.

21. Award Contract for Bay Drive Protected Bike Lanes and Pedestrian Path Design Phase (c402304) (PW)
Motion carried to award a contract to Mark Thomas & Company (San Jose, CA) for Bay Drive Protected Bike Lanes and Path Design Phase in the amount of $449,928 and reject all other proposals and to authorize the City Manager to execute an agreement in a form approved by the City Attorney. The Director of Public Works is authorized to execute amendments within the approved project budget.

8.9 August 13, 2024 CITY COUNCIL MINUTES 6912
Consent Agenda (continued)

22. Digester Gas Piping Rehabilitation Project (m409659) – Notice of Completion (PW)
Motion carried to accept the work of MBS Engineering, Inc. (San Ramon, CA) as completed per plans and specifications and authorize the filing of the Notice of Completion for the Digester Gas Piping Rehabilitation Project (m409659) and authorizing the Public Works Director to sign the Notice of Completion as the Owner’s Authorized Agent.

23. Ocean Street Pavement Rehabilitation Project (c400809) – Notice of Completion (PW)
Motion carried to accept the work of Granite Rock, Inc. (Watsonville, CA) as completed per the plans and specifications and authorize filing the Notice of Completion for the Ocean Street Pavement Rehabilitation Project (c400809) and authorizing the Public Works Director to sign the Notice of Completion as the Owner’s Authorized Agent.

24. Pacific Beach Roundabout Enhancements (c402507) – Professional Services Agreement (PW)
Motion carried to award a contract to RRM Design Group for professional services in the amount of $139,852 and to authorize the City Manager to execute an agreement in a form approved by the City Attorney and authorize the Director of Public Works to execute amendments within the approved project budget.

25. Resource Recovery Facility Enclosed Flare Installation Project (c402512) – Contract Amendment No. 7 and Budget Adjustment (PW)
Motion carried to:
 Authorize the City Manager to execute Contract Amendment No. 7 with Tetra Tech BAS for engineering services for the Resource Recovery Facility Enclosed Flare Installation Project (c402512) in the amount of $1,785,870 in a form approved by City Attorney. The Public Works Director is authorized to execute future amendments within the approved project budget; and

8.10 August 13, 2024 CITY COUNCIL MINUTES 6913
Consent Agenda (continued)

25. Resource Recovery Facility Enclosed Flare Installation Project (c402512) – Contract Amendment No. 7 and Budget Adjustment (PW) (continued)  Adopt Resolution No. NS-30,369 to amend the FY 2025 budget and appropriate funds in the amount of $350,000 for the Resource Recovery Facility Enclosed Flare Installation Project (c402512).

26. Dufour Street and Seaside Street Intersection Improvements - Approval of Plans and Environmental Determination (PW)
Motion carried to:
 Adopt Resolution No. NS-30,370 modifying the intersection of Dufour Street and Seaside Street to a four-way stop and rescinding Resolution No. NS30,326;  Adopt Resolution No. NS-30,371 approving the plans for the four-way stop at Dufour Street and Seaside Street pursuant to Government Code Section 830.6; and
 Find the intersection improvements at Dufour Street and Seaside Street Categorical Exempt under CEQA Guidelines 14 CCR Section 15301(c).

27. West Cliff Drive Stabilization Project (c401501) – Authorization to Accept Funds for Disaster Recovery and Resilience Support (PW)
Resolution No. NS-30,372 was adopted authorizing the City Manager to accept funds from the California Natural Resources Agency for support of repairs and improvements to the West Cliff Drive Stabilization Project (c401501).

28. Beltz 12 Phase 1 Ammonia Removal Improvements Project (c702203) – Notice of Completion (WT)
Motion carried to accept the work of the Don Chapin Company, Inc (Salinas, CA) as completed per plans and specifications and authorizing the filing of a Notice of Completion for the Beltz 12 Phase 1 Ammonia Removal Improvements Project (c702203) and to authorize the Water Director to sign the Notice of Completion as the Owner’s Authorized Agent.

8.11 August 13, 2024 CITY COUNCIL MINUTES 6914
Consent Agenda (continued)

29. Regional Drought Resiliency Project – Intertie 1 (c702205) – Bid Withdrawal and Award to Second Lowest Bidder (WT)
Motion carried to:
 Accept the bid withdrawal of the apparent low bidder, Monterey Peninsula Engineering Inc. (Monterey, CA), for the Regional Drought Resiliency Project – Intertie 1 (c702205), without forfeiting its bid security on the basis that a material and clerical error was made in assembling the bid, as provided in Section 5101 and 5103 of the California Public Contract Code; and
 Award the construction contract for the Regional Drought Resiliency Project – Intertie 1 (c702205) to the second lowest bidder, Pacific Underground Construction Inc. (San Jose, CA), in the amount of $8,758,750 including construction contingency.

End Consent Agenda

8.12 August 13, 2024 CITY COUNCIL MINUTES 6915
Public Hearing

30. Municipal Code Amendments to Chapter 24.12 Relating to Historic Variations Responding to Modifications Requested by the California Coastal Commission.

Location: Citywide. CEQA: Exempt 15061(b)(3) (PL)
Senior Planner S. Neuse spoke.

Mayor Keeley opened the public comment period. There were no speakers.

Mayor Keeley closed the public comment period.

MOTION: Councilmember Brown moved, seconded by Vice Mayor Golder, to:
 Adopt Resolution No. NS-30,373 acknowledging receipt of the resolution of certification from the California Coastal Commission including the suggested modifications; and
 Introduce for publication Ordinance No. 2024-11 finding that the project is exempt under the California Environmental Quality Act (CEQA) and amending parts of Chapter 24.12 of the Santa Cruz Municipal Code (SCMC) related to Historic Variations in response to action by the California Coastal Commission.

ACTION: The motion carried unanimously with the following vote.

AYES: Councilmembers Newsome, Brown, Watkins, Brunner,
Kalantari-Johnson; Vice Mayor Golder; Mayor Keeley.

NOES: None.

ABSENT: None.

DISQUALIFIED: None.

8.13 August 13, 2024 CITY COUNCIL MINUTES 6916
General Business

31. Ordinance Amending Municipal Code Chapter 24.10 and Sections 24.12.190,

24.12.290, and 24.12.1108 and Adding New Sections 24.10.2342 and 24.12.191 to Streamline Permitting and Establish Standards for Private Property Outdoor Seating Associated with Eating and/or Drinking Establishments. Chapters 24.10 and 24.12 are Part of the Local Coastal Program Implementation Plan (LCP IP) and Will Require Approval by the California Coastal Commission Prior to Taking Effect Inside the Coastal Zone, and Ordinance Amending Uncodified Ordinance No. 2020-27 Extending Temporary Use of Certain Adjacent Public Street and Outdoor Areas for Eligible Businesses that Extends the Temporary Period for Commercial Use on Private Property from May 31, 2025, to July 1, 2026. (CEQA:

Exempt Pursuant to CEQA Guidelines Section 15061(b)(3) as a Project that with Certainty Does Not Have an Effect on the Environment and Section 15183 as a Project Consistent with the General Plan for which an EIR Was Certified.) (PL/EDH)
Senior Planner C. Stanger and Economic Development Manager R. Unitt gave a presentation and responded to Council questions.

Mayor Keeley opened the public comment period. The following people spoke.

Unidentified person
Unidentified person
Karen Madura
Patrice Boyle
Garrett
Max Turigliatto
Mayor Keeley closed the public comment period.

MOTION: Councilmember Kalantari-Johnson moved, seconded by Councilmember Brunner, to:
1) Acknowledge the environmental determination and introduce for publication Ordinance No. 2024-12 amending Chapter 24.10 and Sections

24.12.190, 24.12,290, and 24.12.1108, and adding Sections 24.10.2342 and

24.12.191 to streamline permitting for private property outdoor seating areas for eating and drinking establishments.
2) Acknowledge the environmental determination and introduce for publication Ordinance No. 2024-13 amending uncodified Ordinance No. 2020-27 extending temporary use of certain adjacent public street and outdoor areas for eligible businesses that extends the temporary period for commercial use on private property from May 31, 2025, to July 1, 2026.

8.14 August 13, 2024 CITY COUNCIL MINUTES 6917
General Business (continued)

31. Ordinance Amending Municipal Code Chapter 24.10 and Sections 24.12.190,

24.12.290, and 24.12.1108 to Streamline Permitting and Establish Standards for Private Property Outdoor Seating Associated with Eating and/or Drinking Establishments (PL/EDH) (continued)
MOTION (continued):
3) Direct the Mayor to send a letter to state representatives to advocate for all cities to adopt state building code interpretation that does not trigger any new required bathroom fixtures for businesses with 300 square feet or less of outdoor dining or drinking area.

ACTION: The motion carried unanimously with the following vote.

AYES: Councilmembers Newsome, Brown, Watkins, Brunner,
Kalantari-Johnson; Vice Mayor Golder; Mayor Keeley.

NOES: None.

ABSENT: None.

DISQUALIFIED: None.

Adjournment – Vice Mayor Golder moved, seconded by Councilmember Brown, to adjourn. By consensus City Council adjourned at 5:05 p.m.

Respectfully Submitted:

Julia Wood, Deputy City Clerk Administrator
Attest:

Bonnie Bush, City Clerk Administrator
Approved:

Fred Keeley, Mayor

8.15 City Council

AGENDA REPORT
DATE: 08/07/2024
AGENDA OF: 08/27/2024
DEPARTMENT: City Manager
SUBJECT: 2024 A City Like Me: Santa Cruz Report (CM)
RECOMMENDATION: Motion to accept the 2024 A City Like Me report as submitted.

BACKGROUND: In November 2021, the Santa Cruz City Council adopted the anti-racial discrimination resolution (Resolution No. NS-29,893), acknowledging both the historical and ongoing presence of racism and white supremacy within the community. This resolution reestablished the Health in All Policies (HiAP) City Council Committee, which was tasked with developing actionable steps to create a more just, inclusive, and safe community. Furthermore, the resolution committed the City to enhancing diversity in civic leadership by identifying and removing barriers to access, increasing outreach efforts to diverse communities during recruitment for City advisory bodies, and implementing measurable metrics to ensure that community diversity is accurately reflected at all levels of government decision-making. As part of these efforts, in 2022 the HiAP City Council committee and City staff commissioned the community-based organization, Ventures, to conduct a demographics survey and study of City advisory bodies, resulting in the inaugural "A City Like Me: Santa Cruz" report (2022 Like Me Report).

The 2022 Like Me Report revealed significant disparities between the diverse demographics of City residents and the composition of City advisory bodies, including critical underrepresentation of People of Color (PoC), Hispanic/Latino individuals, and renters. Additionally, the report recommended several measures to address these disparities, including collecting demographic information during the application process, educating advisory body members and City residents about the importance of diversity and representation, and collaborating with the County of Santa Cruz to develop comprehensive solutions for achieving equitable representation.

Following publication of the inaugural Like Me report, the City committed to conducting the Like Me survey biannually as part of its ongoing efforts to increase diversity and representation in civic leadership and the recommendations contained in the first Like Me report were integrated into annual HiAP workplans for implementation.

DISCUSSION: The 2024 Like Me Report (Attached) provides a comprehensive summary of the results and key findings from the City’s second survey of advisory bodies, the report also provides a progress update on the City's implementation of the recommendations from the initial 2022 Like Me report.

9.1 Progress Update
Over the past two years the City has taken several actions to implement the recommendations contained in the 2022 Like Me Report. Some of the notable actions taken include:
• The HiAP City Council Committee overseeing the shaping and implementation of recommendations from the 2022 "Like Me" report, including setting goals for increased representation of Hispanic/Latino and renter populations. • The City Clerk updated the advisory body application to include voluntary demographic questions and the Advisory Body Handbook to include information about the City's Like Me and HiAP initiatives.
• In September 2023, City and County staff jointly facilitated a virtual meeting with communitybased organizations to increase public awareness about City/County advisory bodies and to gather public feedback on barriers to serving on advisory bodies. • In 2024 the City developed a Youth Liaison Program to integrate youth under 18 years old in the City’s decision making.
• City staff budgeted for compensation for advisory body members and are currently developing an opt-in compensation policy for advisory body members that, if approved by CN, will go into practice in January 2025.
• In summer 2024, the City Manager directed the Sustainability and Resiliency Officer to visit committees and commissions to provide training and an update on HiAP, Sustainability and Resiliency to advisory bodies, including an update on the 2024 Like Me report and findings.

As noted in the 2024 Like Me Report, although the City’s actions over the past two years illustrate its commitment to working collaboratively across departments, it is still too early to accurately assess their impact on applicant recruitment and overall representation.

Key Findings
In Spring 2024, all 94 advisory body members were invited via email to participate in the 2024 Like Me survey through a link to the online survey. Participation was voluntary, and no personal identifying information was collected. A total of 65 surveys were submitted, resulting in a 69% response rate. The survey data was compared to both the 2022 Like Me survey results and Citywide demographics data to identify representation disparities in advisory body representation including zip code, age, race/ethnicity, education level, gender, veteran status, disability identity, housing status, and income level.

Staff’s analysis of the survey data produced several key findings:
• Hispanic/Latino Representation: While the proportion of Hispanic/Latino individuals serving on advisory bodies has doubled since 2022, increasing from 5% to 10% in 2024, Hispanic/Latino people remain underrepresented when compared to their 21% share of the City's population. • Renter's Representation: The proportion of renters on advisory bodies decreased from 28% in 2022 to 22% in 2024.Currently, renters make up 53% of the City’s population, meaning they are underrepresented by 31%, the largest variance for any group in the 2024 survey.

9.2 • Age Disparities: Young adults (18-24) are critically underrepresented, making up only 2% of advisory body members despite being 31% of the City's population. Conversely, individuals aged 65 and over are overrepresented, comprising 43% of advisory body members compared to their 13% share of the population.
• Geographic Disparities: Residents of zip code 95060 are critically overrepresented, constituting 72% of advisory body members while only making up 46% of the city's population.

Recommendations
The 2024 Like Me Report includes several recommendations for the HiAP City Council Committee to consider when developing the 2025 City HiAP work plan. These recommendations include:
• Targeted Outreach to Renters: Implement strategies to engage renters, such as facilitating community meetings in rental complexes, creating a renters mailing list, and partnering with community-based organizations that provide services to renters. • Targeted Outreach to Young Adults: Conduct outreach to local schools and universities, and collaborate with the County on recruitment efforts.
• Goal Development: Develop goals that directly address the variance between the City's population and advisory bodies to ensure consistent progress evaluations. • More Research is Needed: To fully assess how the City’s actions are impacting applicant recruitment, and the overall representativeness of City advisory bodies continue conducting the Like Me survey biannually and focus on evaluating trends over time.

Next Steps
The 2024 Like Me Report highlights the notable progress the City has made in implementing the recommendations from the 2022 Like Me Report and increasing Hispanic/Latino representation on advisory bodies. However, persistent disparities in representation underscore the importance of the City's continued efforts to achieve equitable representation for all City residents. As City staff work with the HiAP committee to develop the 2025 HiAP workplan, the report's findings and recommendations will provide a roadmap for future actions to enhance diversity and inclusion on City advisory bodies.

Health in All Policies (HiAP)
The City’s efforts to increase diversity and representation on City advisory bodies aims to integrate historically underrepresented communities, such as people of color, and renters, into local government advisory and decision-making processes, thus supporting HiAP’s core equity pillar. Additionally, incorporating diverse voices into government decision-making is expected to contribute to the development of public health and sustainability policies that better reflect the needs of all City residents and contribute to improving community well-being.

FISCAL IMPACT: No immediate fiscal impact is associated with this report.

9.3 Prepared By:

Berny Lazareno
Management Analyst
Approved By:

Matt Huffaker
City Manager
ATTACHMENTS:

1. 2024 A CITY LIKE ME SANTA CRUZ REPORT.PDF

2. 2022 A CITY LIKE ME SANTA CRUZ REPORT.PDF

9.4 A City Like Me:

Santa Cruz
2024

9.5 Table of
Contents
01 Purpose
02 Background
04 Methodology &
Participation
05 New Targets
06 Key
Findings
08 Recommendations
10 Survey
Data Tables
15 Acknowledgement

9.6 01
Purpose
The “2024 A City Like Me: Santa Cruz" (Like Me) survey is a key component of the City of Santa Cruz’s (City) broader Health in All Policies (HiAP) initiative. The survey evaluates the current state of representation on City advisory bodies and identifies potential disparities in relation to the diverse demographics of the community.

By evaluating the composition of City advisory bodies, the City aims to develop evidence-based strategies that bolster representation and foster inclusivity to ensure that all voices are heard in the decisionmaking processes that shape Santa Cruz. This commitment to equitable representation is foundational to the City's pursuit of a just, equitable, and thriving community where everyone feels a sense of belonging and has the opportunity to contribute to the collective wellbeing. This report presents the key findings from the 2024 Like Me survey, and provides recommendations for improving representation on City advisory bodies.

The 2024 Like Me survey aims to assess and
improve the representation and diversity of
City advisory bodies, ensuring all community
voices are heard in decision-making
processes.

9.7 02
Background
In November 2021, the Santa Cruz City Council adopted the anti-racial discrimination resolution (Resolution NO. NS-29,893), acknowledging the history and ongoing presence of racism and white supremacy in the community. This resolution revived the HiAP City Council Committee and tasked it with developing concrete, actionable steps to foster a more inclusive and safe community. Additionally, the ordinance committed the City to increasing representation and diversity in civic leadership by identifying and removing barriers to access, improving outreach to diverse organizations during recruitment for City advisory bodies, and implementing measurable metrics to ensure the community's diversity is reflected at all levels.

In 2022, City staff partnered with community-based organization Ventures to produce the first Like Me report. The report’s key findings highlighted several significant disparities including:
overrepresentation of residents from zip code 95060
underrepresentation of People of Color (PoC)
underrepresentation of Hispanic/Latino residents
underrepresentation of renters
To address these disparities, the report recommended several actions:
establishing a committee to monitor and address these disparities, collecting demographic data during the application process, educating advisory body members about the importance of diversity and representation, and collaborating with the County of Santa Cruz (County) to develop comprehensive solutions for equitable representation across all community segments.

9.8 03
Over the past two years, City elected officials and staff from multiple departments have worked collaboratively to implement the recommendations contained in the 2022 City Like Me report.

Summary of Implementation Actions:

The HiAP Committee oversaw implementation of the 2022 Like Me report recommendations, including receiving progress updates from City and County staff and developing goals for increasing Hispanic/Latino and Renters representation on advisory bodies which were adopted by City Council in December 2023.

The City Clerk’s Office updated the advisory body application to include voluntary demographics questions and the Advisory Body Handbook to include information about the City’s Like Me and HiAP initiatives.

City staff have collaborated with County staff to raise public awareness about the role of advisory bodies in local government, upcoming openings, and the application and appointment process.

In September 2023, City and County staff jointly facilitated a virtual community meeting to discuss the City and County’s
representation goals, and solicit public feedback about barriers to serving on advisory bodies.

Staff developed the City’s Youth Liaison Program to formally integrate youth under 18 years old in local government decisionmaking.

In 2024, City staff started development of a City compensation policy for advisory body members which, upon approval by City Council, is tentatively scheduled to go into practice in January 2025.

The fiscal year 2024 adopted budget includes funds for advisory body compensation.

9.9 04
To assess trends in advisory body representation, the City has committed to conducting the Like Me survey biannually. This report summarizes the results and key findings of the City’s second survey of advisory bodies. Staff designed the survey specifically for individuals serving on City advisory bodies which includes committees, commissions, task forces, boards, and City Council.

Survey response data was compared to City population data from the 2022 American Community Survey and 2020 U.S. Census to assess how representative advisory bodies are of the City's population based on zip code, age, race/ethnicity, education level, gender, veteran status, disability identity, housing status, and income level. Additionally, the 2024 City survey data was compared to the 2022 City survey data to capture changes in the demographic makeup of advisory bodies from 2022 to 2024.

To maintain consistency with the methodology employed in the 2022 Like Me survey analysis, variances of 10% or more are referred to as “critical under or over representation.”
Methodology
Participation
All advisory body members were eligible to
participate in the 2024 Like Me survey. In the Spring
of 2024, a link to the online survey was provided to
all advisory body members via email. Participation
in the survey was entirely voluntary, and all
responses were collected anonymously. In total, 65
out of 94 individuals serving on advisory bodies
completed the survey for a response rate of 69%.

9.10 05
Goal 1
Goal 2
New Targets
As part of the City’s efforts to address the disparities identified in the 2022 Like Me report, the City Council adopted two goals to increase participation of
underrepresented groups on advisory bodies,
completing one action on the 2024 HiAP Workplan.

Increase Hispanic/Latino representation
on advisory bodies by 60% from its 2022
baseline level by 2025.

Increase renters representation on
advisory bodies by 30% from its 2022
baseline level by 2025.

9.11 06
Key Findings
Significant Increase in Hispanic/Latino Representation
The City achieved its goal of a 60% increase in Hispanic/Latino representation, with the proportion of Hispanic/Latino survey respondents doubling from 5% in 2022 to 10% in 2024. The 100% increase indicates progress towards greater representation. However, despite the progress made, it is important to note that Hispanic/Latino residents remain critically underrepresented on advisory bodies compared to their proportion of the City's population. Hispanic/Latino residents make up 21% of the City’s population, and only 10% of advisory body members, resulting in a 11% underrepresentation. So, while progress has been made to achieve this goal, the City will need to prioritize attention toward maintaining and even increasing representation of Hispanic/Latinos on advisory bodies.

Decrease in Renters Representation
Survey data shows that renter representation decreased from 28% in 2022 to 22% in 2024. This 21% decrease presents a challenge to meeting the City's goal of increasing renter representation by 30% from its 2022 base value by 2025. Currently, renters make up 53% of the City’s population, and only 22% of advisory body members, an
underrepresentation of -31%. The 31% variance is the largest variance for any group in the 2024 survey.

9.12 07
Key Findings
Critical Overrepresentation of Zip Code 95060
Residents in zip code 95060 are overrepresented in City advisory bodies by 26 percentage points. 72% of survey respondents live in the 95060 zip code, while only 46% of city residents live there. Although, less than half of City residents live in the 95060 zip code, approximately 3 out of every 4 advisory body members lives in this zip code, indicating that overrepresentation of this zip code potentially impacts all advisory bodies.

Critical Overrepresentation According to Age
Youth under 18 years old make up 12% of the City’s population and 0% of advisory body members. Young adults aged 18-24 years old are critically underrepresented, making up only 2% of advisory body members compared to 31% of the City's population, a variance of -29%. In contrast, individuals aged 65 and over are overrepresented, comprising 43% of advisory body members while they represent only 13% of the City's population, a variance of +30%.

9.13 08
Recommendations
Targeted Outreach to Renters
The survey reveals critical underrepresentation of renters on advisory bodies compared to the city's general population. To address this disparity, consider implementing targeted outreach strategies to engage renters, such as facilitating community workshops in rental complexes, creating a renters mailing list, and direct invitations to renters to apply for openings. Additionally, explore opportunities to partner with local housing and renter serving organizations to conduct outreach to renters.

Targeted Outreach to Youth and Young Adults
Over the past year, staff developed the City’s Youth Liaison Program to more formally integrate youth under 18 years old in local government decision-making. Although the Youth Liaison is not appointed to an advisory body, future evaluations should consider including the City’s Youth Liaison in their surveys as this will provide a more accurate analysis of youth representation in City government. Currently, the City’s Park and Recreation (P&R) Department is also exploring opportunities to formally integrate youth under 18 years old into the City’s advisory structure, including potentially standing up a youth subcommittee of the P&R Commission. Consider including an update from P&R on youth integration as part of the HiAP 2025 Workplan.

To address the age disparity for young adults 18-24 years old on City advisory bodies, consider conducting outreach to local schools, Cabrillo College and University of California Santa Cruz.

Additionally, consider collaborating with the County on young adult/youth recruitment.

The HiAP Committee will consider the following recommendations when developing the next HiAP workplan.

9.14 09
Recommendations
Goal Development
As part of the 2025 HiAP Workplan consider developing additional goals that address the underrepresentation/overrepresentation of specific groups identified in this report. When developing goals, consider developing goals that directly address the variance between the City’s population and City advisory bodies rather than a percentage increase/decrease for a specific group. For example, instead of targeting a 60% increase in Hispanic/Latino
representation from the 2022 baseline, the City could set a goal to decrease underrepresentation of Hispanic/Latino residents from -11% to -8%. This approach would directly address the existing underrepresentation/overrepresentation of specific groups and allow for more consistent progress evaluations over time.

More Research is Needed
The recommendations from the 2022 Like Me report were
implemented and put into action over the past 2 years. 2 years is a relatively short period to assess their full impact. Additionally, various factors influence representation on City advisory bodies year to year. These factors include the number of openings, which committees or commissions have openings, committee and
commission rules, applicants’ schedules, and childcare availability.

Each of these variables can significantly impact who is able and willing to serve on City advisory bodies.

More research is necessary to fully assess how these
recommendations are affecting recruitment and the overall representativeness of City advisory bodies. Therefore, it is recommended that the City continue conducting its biannual Like Me survey, continue its public engagement and education activities, and focus on evaluating trends over time rather than any specific point in time to gain a clearer and more accurate understanding of community representation on City
advisory bodies.

9.15 10
Age
Range
2022
Survey
2024
Survey
Change City Data
City
Variance
Under
18 0% 0% 0% 12% -12%
18-24 0% 2% 2% 31% -29%
25-64 65% 55% -10% 44% 11%
65 and
over
35% 43% 23% 13% 30%
Disability
Identity
2022
Survey
2024
Survey
Change City Data
City
Variance
Yes 9% 11% 2% 8% 3%
No 91% 89% -2% 92% -3%
Survey Data Tables
The following tables contain a comparison between the
2022 and 2024 Like Me surveys as well as the variance for each demographic characteristic evaluated from overall
City demographics (source: US Census). The City variance column includes the difference between the City’s
population and the demographic makeup of advisory
bodies.

Age
Disability

9.16 11
Level
of
Education
2022
Survey
2024
Survey
Change City Data
City
Variance
High School
or
Equivalent
2% 0% -2% 13% -13%
Some
college
5% 10% 5% 21% -11%
Associates 2% 6% 4% 8% -2%
Bachelors 49% 37% -11% 28% 9%
Masters 33% 35% 2% 15% 20%
Doctorate 9% 6% -3% 4% 2%
Professional 0 6% 6% 4% 2%
Gender
2022
Survey
2024
Survey
Change City Data
City
Variance
Male 52% 47% -5% 49% 2%
Female 45% 53% 8% 51% -2%
Nonbinary 2% 0% -2% n/a n/a
Transgender 2% 0% -2% n/a n/a
Other* n/a 0% n/a n/a n/a
Education
Gender
*This response category was not previously included in the 2022 Like Me survey.

9.17 12
Housing
Status
2022
Survey
2024
Survey
Change City Data
City
Variance
Homeowner 71% 78% 7% 47% 31%
Renter 28% 22% -6% 53% -31%
Other 2% 0% -2% n/a n/a
Income
2022
Survey
2024
Survey
Change
City
Data
City
Variance
less than $15,000 0% 3% 3% 10% -7%
$15,000 - $24,999 2% 0% -2% 6% -6%
$25,000 - $34,999 0% 3% 3% 7% -4%
$35,000 - $49,999 2% 6% 4% 8% -2%
$50,000 - $74,999 12% 14% 2% 8% 6%
$75,000 - $99,999 16% 20% 4% 8% 12%
$100,000 - $124,999 21% 12% -9% 9% 3%
$125,000 - $149,000 7% 11% 4% 7% 4%
$150,000 - $199,999 23% 17% -6% 12% 5%
$200,000 and over 16% 14% -2% 24% -10%
Housing
Income

9.18 13
Race/Ethnicity
2022
Survey
2024
Survey
Change
City
Data
City
Variance
American Indian or Alaskan
Native
0% 0% 0% 1% -11%
Asian 2% 0% -2% 10% -10%
Black or African American 3% 5% 2% 2% 3%
Hispanic or Latino 5% 10% 5% 21% -11%
Multiracial* n/a 6% n/a 11% -5%
Native Hawaiian and other
Pacific Islander
0% 0% 0% 0% 0%
White 85% 77% -8% 61% 16%
Other (Not Hispanic or Latino)* n/a 2% n/a 8% -6%
Veteran
Status
2022
Survey
2024
Survey
Change
City
Data
City
Variance
Yes 7% 14% 7% 3% 11%
No 93% 86% -7% 97% -11%
Race/ Ethnicity
Veteran
*This response category was not previously included in the 2022 Like Me Survey.

9.19 14
Zip Code
2022
Survey
2024
Survey
Change
City
Data
City
Variance
95060 69% 72% 3% 46% 26%
95062 26% 27% 1% 36% -9%
95063 n/a 0% n/a n/a 0
95064 3% 0% -3% 10% -10%
95065 2% 2% 0% 8% 6%
Zip Code

9.20 15
Acknowledgement
The City appreciates the contributions of community based organization Ventures and their staff to this report. Ventures, is an organization that works towards creating a shared and prosperous economic future where zip code, race, gender, or immigration status do not dictate income or wealth.

9.21 The Value of Representational Government
A City Like Me: Santa Cruz
www.sccvonline.org
PO Box 2375
Watsonville, CA 95077
powered by

9.22 This report is made possible through a partnership between Ventures and the City of Santa Cruz. It expands and complements a similar effort, “A Santa Cruz Like Me,” undertaken in 2021 with the County of Santa Cruz. Both efforts aim to ensure that the diversity of our government reflects the diversity of our region.

Different lived experiences can help inform and shape policy and governance. “A City Like Me: Santa Cruz” paints a picture of the City of Santa Cruz’s elected and appointed representative bodies including City Council and twelve (12) Commissions and Committees. It is a start to explore and identify how we are doing as a city, with a goal of ensuring a resilient, prosperous and equitable future for all.

Key Findings

1. Critical Over Representation of Zip Code 95060 Survey results show a 22% over representation as compared to census data (69% vs 47%). This zip code represents 50% of high-income households ($100K+) and college graduates in the City of Santa Cruz. Thus, making this specific zip code over representation impact all other aspects of lived experience and demographic representation at commission and board levels.

2. Critical Over Representation Based on Age, Education Level, and Income Survey results show critical over representation as compared to census data. This includes zero representation of young adults (ages 18-24) or a 20% variance, a 38% variance in those who indicated having a 4-year college degree or higher (91% vs 53%), and a variance of 26% for households earning $100K or higher (67% vs 41%). It is important to note that not all residents of zip code 95060 reported their household income, to which may indicate an under reporting of those living in households earning $100K or higher.

3. Critical Under Representation of People of Color Data shows a 34% under count of people of color, based on race and ethnicity indicators, in the make-up of boards and commissions. With the greatest variance (17%) showing up for Latino identified population based on the survey responses (5%) as compared to city population totals (23%). It is important to note that 43% of Latino identified city residents live in zip code 95060 and that the county also showed a 19% variance for Latinos on their boards and commissions. These findings point to the need for further analysis on Latino engagement and recruitment.

4. Critical Under Representation of Renters Renters make up only 28% of board and commission membership, as compared to 54% of the general population. This was also seen at the County level where a similar 28% variance was found. Given the housing crisis, representation by tenants would provide needed perspectives to housing solutions.

EXECUTIVE SUMMARY
Table of Contents
Executive Summary . . . . . . . . . 2
Background . . . . . . . . . . . . . . . . 3
Methodology & Participants . . 4
Findings . . . . . . . . . . . . . . . . . . . 5
Recommendations . . . . . . . . . . 7
Appreciation . . . . . . . . . . . . . . 8
2 • powered by Ventures 9.23

BACKGROUND
“A City Like Me: Santa Cruz” was inspired by efforts within the City of Santa Cruz’ Health in All Policies work and Santa Cruz County’s “A Santa Cruz Like Me” report. The policies and decisions our local leaders form and vote on directly affect our communities. Underscoring the importance that our leaders reflect and understand the diversity of the region.

As an organization interested in building an equitable economy, Ventures recognizes the value of a representative government and how this can affect economic decisions. This data-driven effort also aligns with the City of Santa Cruz’s Strategic Plan goals to create a vibrant city that preserves the diversity and quality of its natural and built environment and creates a satisfying quality of life for its diverse population and workers.

A City Like Me: Santa Cruz • 3 9.24

METHODOLOGY
The survey was delivered in the Summer of 2022
to City of Santa Cruz’s commissions, committees,
and City Council members to voluntarily disclose
demographic and population descriptive indicators.

The data collected was compared to American
Community Survey (ACS) and U.S. Census populationlevel data using DataShare Santa Cruz, the central hub of information for Santa Cruz County. In addition,
the team reviewed and compared overall population
data from the County’s “A Santa Cruz Like Me” report.

The report highlights indicators with variances of 5%
or higher from the population, with special review of
variances of 10% or higher.

PARTICIPATION
All commissions and boards
participated in the survey, with
63% of all possible respondents
completing the survey. It is
important to note that some
participants opted out of
certain questions. City survey
percentages reflect calculations
based solely on data attained
from respondents that
completed the respective survey
question.

City Survey Data City Data City Variance
County Survey
Data County Variance
Zipcode
95060 69% 47% 22% 22% 4%
95062 26% 36% -10% 14% 0%
95063 n/a n/a n/a n/a n/a
95064 3% 9% -6% n/a n/a
95065 2% 8% -6% 7% 4%
Age
Under 18 0% 15% -15% n/a n/a
18-24 0% 20% -20% 0% -14%
25-64 65% 47% 18% 67% 18%
65-84 35% 16% 19% 35% 19%
85-up 0% 2% -2% 0% -2%
Gender
Female 52% 49% 3% 61% 10%
Male 45% 51% -6% 38% -11%
Nonbinary 2% n/a n/a 1% n/a
Transgender 2% n/a n/a n/a n/a
Disability Identity
Yes 9% 9% -0% 17% -17%
No 91% 91% -0% 77% n/a
4 • powered by Ventures 9.25
City
Survey Data City Data City Variance
County
Survey Data County Variance
Race and Ethnicity
American Indian and Alaska Native 0% 1% -1% 2% 2%
Asian (Non Hispanic or Latino) 2% 8% -6% 2% -6%
Black or African American 3% 2% 1% 2% 1%
Hispanic or Latino 5% 23% -17% 16% -19%
Native Hawaiian and Other Pacific
Islander 0% 0.2% -0.2% n/a n/a
White 85% 72% 13% 72% -13%
Other (Non Hispanic or Latino) 0% 11% -11% n/a n/a
Education
High school diploma or equivalent 2% 18% -16% 2% -14%
Some college, no degree 5% 22% -17% 7% -15%
Associate degree 2% 7% -5% 4% -4%
Bachelor's degree 49% 30% 19% 33% 10%
Master's degree 33% 15% 18% 28% 17%
Doctorate 9% 4% 5% 11% 9%
Professional degree 0% 4% -4% 6% 3%
Veteran Status
Yes 7% 9% -2% 92% n/a
No 93% 91% 2% 8% n/a
Housing Status
Homeowner 71% 46% 24% 77% 26%
Renter 28% 54% -26% 22% 28%
Other 2% n/a 2% 1% 2%
Income
Less than $15,000 0% 10% -10% n/a n/a
$15,000 to $24,999 2% 8% -6% n/a n/a
$25,000 to $34,999 0% 6% -6% n/a n/a
$35,000 to $49,999 2% 9% -6% n/a n/a
$50,000 to $74,999 12% 14% -2% n/a n/a
$75,000 to $99,999 16% 12% 4% n/a n/a
$100,000 to $124,999 21% 9% 12% n/a n/a
$125,000 to $149,999 7% 8% -1% n/a n/a
$150,000 to $199,999 23% 9% 15% n/a n/a
$200,000 and Over 16% 15% 1% n/a n/a
A City Like Me: Santa Cruz • 5 9.26

KEY FINDINGS
3 Critical Under Representation of People
of Color. Data shows a 34% under count of
people of color, based on race and ethnicity
indicators, in the make-up of boards and
commissions. With the greatest variance (17%)
showing up for Latino identified population
based on the survey responses (5%) as
compared to city population totals (23%). It is
important to note that 43% of Latino identified
city residents live in zip code 95060 and that
the county also showed a 19% variance for
Latinos on their boards and commissions. These
findings point to the need for further analysis
on Latino engagement and recruitment. It
is also important to note a variance (11%) in
respondents that identified as “other.”
4 Critical Under Representation of
Renters. Renters make up only 28% of board
and commission membership, as compared
to 54% of the general population. This was
also seen at the County level where a similar
28% variance was found. Given the housing
crisis, representation by tenants would provide
needed perspectives to housing solutions.

While these findings are grouped by individual
indicators, we recognize that they all can and
do impact each other. For example, higher
education tends to correlate with a higher
income, which may impact residents’ ability to
afford home ownership.
1 Critical Over Representation of Zip Code 95060.

Survey results show a 22% over representation as compared to census data (69% vs 47%). This zip code represents
the area known as the Westside of Santa Cruz, which
includes downtown and areas surrounding the University
of California, Santa Cruz. It is important to note that based on the 2021 American Community Survey (ACS) 50% of
high-income households ($100K+) and college graduates in the city reside in this zip code. Thus, making this specific zip code over representation impact all other aspects of lived experience and demographic representation at commission and board levels.
2 Critical Over Representation Based on Age, Education
Level, and Income. Survey results show critical over
representation as compared to census data based on age, education level, and income. This includes:
• 0% representation of young adults (ages 18-24), or a
variance of 20%. This is reflected in part by an over
representation in both working adults (ages 25-64) and
retirees (ages 65+).
• 38% variance in those who indicated having a 4-year college degree or higher (91% vs 53%). This includes an 18% over representation of those with Master’s degrees; and
• 26% variance for households earning $100K or higher (67% vs 41%). It is important to note that not all residents of zip code 95060 reported their household income, to which may indicate an under reporting of those living in households earning $100K or higher.

Given that higher education tends to correlate with higher income, this may impact the ability for inclusive workforce development and economic development policies adopted
by the city.
6 • powered by Ventures 9.27

RECOMMENDATIONS

1. Create a Committee to Review Variances
and Propose Solutions. In alignment with City
of Santa Cruz’s vision to create a satisfying
quality of life for its diverse population and
workers, it is recommended that a committee be
formed that includes community members from
groups that are under represented to provide
recommendations to address variances in the
next 6 months. Committee members would be
charged with exploring solutions to decrease
existing variances and monitoring progress.

The committee should report on their progress
within one year of its creation.

2. Embed Collection of Demographic
Information During Application and
Onboarding. To capture a complete picture of
who is applying and ultimately appointed, it is
recommended that demographic information
be collected during the application process for
all board and commission positions. Elected
officials should also receive a City demographic
report during onboarding. This information
should be reviewed on a timely basis to ensure
outreach is reaching all members of the
community.

3. Educate Applicants on the Demographic
Information Collection as a Key Strategic. To support
the engagement and data collection process, it is
important that candidates for appointment understand
the purpose and role of the data collection process. This includes the need for participants to answer all questions in the survey. Elected officials with appointment power should help inform candidates and staff of the value
of the process in alignment with the city’s goals and
strategy.

4. Include City Data Review as Part of the
Onboarding Process. It is recommended that the
onboarding process for appointees, including those with appointment power, include a review of the demographic
makeup of the city and the data dashboards that are
available. Furthermore, appointees and elected members
should receive guidance and training on ensuring they
consider experience of population or groups not currently represented, including providing language accessibility for non-English speakers.

5. Work with the County of Santa Cruz to Review
Variances Within Both City and County. Given some
populations were found to be under represented both at
the city and county level, it is recommended these two
jurisdictions work together to identify common causes,
leverage approaches, and propose solutions.

A City Like Me: Santa Cruz • 7 9.28
About Ventures
Ventures partners with rural Latino working-class families in California’s Central Coast to implement transformational programs that activate and strengthen their economic and political power.

Together, we are working towards a shared and prosperous economic future where zip code, race, gender, or immigration status do not dictate income or wealth. sccvonline.org
About Health In All Policies Committee
Nestled between the Santa Cruz Mountains and the
Monterey Bay, the City of Santa Cruz’ unrivalled environment creates a thriving and open culture that invites innovation, entrepreneurship, and an ethos of keeping it real. Known for its vibrant community and pristine natural environments, the City is home to 65,000 residents and welcomes tourists from across California and the world. The economy is anchored in tourism and technology and is home to world class arts, cultural and education institutions. Distinguished by residents with diverse ethnicities, socioeconomic backgrounds and life experiences, Santa Cruz offers an incredible quality of life. In 2017 Time Magazine was named the third Healthiest and Happiest City in the US. In 2018, the city was named one of the “Top 100 Best Places to Live” by livability.com and one of the “30 Best Small Cities in the U.S.” by National Geographic’s Traveler magazine.

Through its Health in All Policies initiative initiated in 2019, the City has prioritized community well-being through a focus on equity, public health and sustainability in its policy making; Santa Cruz Like me is an outcome of the Health in All Policies initiative.

APPRECIATION
8 • powered by Ventures 9.29
City Council

AGENDA REPORT
DATE: 08/07/2024
AGENDA OF: 08/27/2024
DEPARTMENT: City Council
SUBJECT: Endorsement of California Senate Bill 867 (CN) RECOMMENDATION: Motion to direct the Mayor to send a letter of endorsement in support of California Senate Bill 867.

BACKGROUND: Senate Bill (SB) 867 is a legislative proposal aimed at addressing various environmental and climate related challenges in California. This bill seeks to establish the “Drought and Water Resilience, Wildfire and Forest Resilience, Coastal Resilience, Extreme Heat Mitigation, Biodiversity and Nature-Based Climate Solutions, Climate Smart Agriculture, and Park Creation and Outdoor Access Bond Act of 2023.” If enacted, it would authorize the issuance of a state bond to fund critical projects related to water and drought resilience, wildfire and forest health, coastal protection, heat mitigation, biodiversity, climate resilience and etc.

SB 867 proproses the creation of a new fund, the Drought and Water Resilience, Wildfire and forest resilience, Coastal Resilience, Extreme Heat Mitigation, Biodiversity and Nature-Based Climate Solution fund. This bill authorizes the issuance of general obligation bonds (the “Climate Bond’) in an unspecified amount, to be determined by the legislature and finance committee. These bonds would be repaid from California’s General Fund. SB 867 includes provisions for bond issuance, fund management, and repayment, following established state laws and procedures. SB 867 represents a significant investment in California’s environmental and climate resilience, aligning with ongoing state strategies and addressing pressing climate challenges through a comprehensive approach to funding and implementation.

SB 867 provides a structured framework for distributing bond proceeds across critical areas such as drought resilience and wildfire prevention, ensuring targeted investments based on priority needs. By issuing general obligation bonds and adhering to established financial practices, the bill secures the necessary resources for large scale projects while maintaining fiscal responsibility and long-term sustainability.

DISCUSSION: Santa Cruz faces several passing environmental challenges that make the Climate Bond pertinent. Funds raised through the Climate Bond’s issuance are allocated to grant programs designed to assist local governments. For example, the City relies heavily on local water sources such as the San Lorenzo River. Grant funds related to drought and water resilience could help Santa Cruz enhance water supply reliability through water recycling and reuse technologies. The 2020 CZU lighting complex fires underscored the City’s susceptibility to wildfires, affecting both the community and natural environment. Grant funds from the Climate

10.1 Bond could be invested in wildfire prevention and forest health restoration, reducing wildfire risk and improving forest management.

Santa Cruz’s location makes it vulnerable to sea level rise and coastal erosion. The City’s waterfront areas like the Boardwalk and West Cliff are at risk from both episodic events and climate change impacts. Grant allocations for coastal resilience programs would provide vital resources for protecting coastal lands, restoring wetlands, and addressing sea level rise. Because Santa Cruz is such a biodiverse hotspot, protecting biodiversity is crucial for maintaining ecological balance and supporting the health of local environments. Grant funds to preserve and protect conservation efforts, habitat restoration projects, and strategies to enhance the resilience of local ecosystems would benefit the City.

Funding obtained through the Climate Bond, primarily via grants and technical assistance, has the potential to significantly bolster the City’s efforts to address its environmental and climate challenges. By securing funding for drought and water resilience, wildfire prevention, coastal protection, biodiversity conservation, and park development, Santa Cruz can enhance its resilience to climate change, protect its natural resources, protect public safety and improve the quality of life for its residents. Furthermore, 40% of the bond measures’ funds are to be distributed to disadvantaged communities. Thus, this bill is in direct alignment with the Health in All Policies Initiatives’ three pillars of equity, sustainability and public health.

FISCAL IMPACT: There is no fiscal impact associated with providing a letter of endorsement for this bill.

Submitted By:

Shebreh Kalantari-Johnson
Councilmember
Submitted By:

Fred Keeley
Mayor
Submitted By:

Scott Newsome
Councilmember
ATTACHMENTS:

None.

10.2 City Council

AGENDA REPORT
DATE: 08/07/2024
AGENDA OF: 08/27/2024
DEPARTMENT: Fire
SUBJECT: Approve Purchase of Pierce Enforcer Pumper Fire Engine and Lease Agreement with PNC Equipment Finance (FD)
RECOMMENDATION: Motion to:
1) Award a contract for the purchase of a Pierce Enforcer Pumper Fire Engine (Apparatus) to Golden State Fire Apparatus in the amount of $1,029,503.26. 2) Adopt a resolution approving a lease agreement with PNC Equipment Finance to prepay for the purchase and finance the Apparatus for the City with a 5.32% interest rate over three (3) years for a total cost of $1,140,934.14; and authorizing the City Manager to execute the agreement and related documents in a form to be approved by the City Attorney.

BACKGROUND: The Fire Department follows an apparatus replacement program according to the National Fire Protection Association (NFPA) 1911 standards. Following NFPA 1911 standards allows the Fire Department to be equipped with reliable apparatus to meet and enhance public safety within the community. In FY25 one (1) Apparatus is due to be replaced per NFPA 1911. Apparatus build time is currently 35–38 months, orders must be placed accordingly for apparatus to be delivered in time to maintain compliance with NFPA 1911 standards.

On June 11th, 2024, the City Council provided direction during the FY25 budget hearing for the Finance Department, City Manager’s Office, and the Fire Department to explore purchasing an apparatus within 3-6 months and develop an apparatus replacement funding program for future purchases.

DISCUSSION: The Finance Department, City Manager’s Office, and Fire Department explored multiple options to purchase an Apparatus in FY25. It was mutually agreed upon to execute an agreement with Golden State Fire Apparatus, Pierce Manufacturing’s California dealer/distributor, utilizing a 3-year lease agreement with PNC Equipment Finance. Pierce Manufacturing and PNC Equipment Finance will partner to provide a tax-exempt municipal leasing program for the Apparatus. (A sample template is attached for reference). Utilizing a lease agreement allows the City to take advantage of the 100% prepay discount in the amount of $132,105. The City will pay for the Apparatus in annual installments, over three (3) years, beginning in FY26 with a 5.32% interest rate. The Apparatus will be owned outright by the City of Santa Cruz (City) after the final installment is paid. This purchase agreement with Golden State Fire Apparatus was executed on July 31, 2024, to avoid a 1.75% price increase.

11.1 The City is a member of Cooperative Sourcewell and will utilize the Sourcewell cooperative contract to purchase this Apparatus. Sourcewell contract #113021-OKC-1 is effective through February 10, 2026. The cooperative contract has been awarded through a formal RFP procurement process. Cooperative agreements result from a procurement process completed by a consortium and then are authorized for use by participating agencies, of which the City is a member.

FISCAL IMPACT: There will be no fiscal impact to the City in FY25. PNC Equipment Finance will complete prepayment to Golden State Fire Apparatus in the amount of $1,029,503.26. In FY26 the City will commence a three (3) year payment plan in the amount of $380,311.38 annually to PNC Equipment Finance in the total amount of $1,140,934.14. At the conclusion of payment, the City will have saved $34,090.36 through our lease agreement with PNC Equipment Finance overpaying in full at time of delivery per Option B in the attached Pierce Executed Agreement.

Prepared By:

Megan Nutt
Principal Management
Analyst
Submitted By:

Rob Oatey
Fire Chief
Approved By:

Matt Huffaker
City Manager
ATTACHMENTS:

1. PIERCE EXECUTED AGREEMENT.PDF

2. PNC LEASE PURCHASE.PDF

3. PNC LEASE RESOLUTION.DOCX

4. PNC LEASE SAMPLE AGREEMENT.PDF

11.2 PREPARED ESPECIALLY FOR:

CITY OF SANTA CRUZ
One (1) Pierce Manufacturing, Inc.

Enforcer 1250 GPM Type 1 Engine

11.3 Product Proposal
Standard Terms and Conditions (Exhibit A)
Product Specifications (Exhibit B)
▪ Supporting Documents (If Applicable)
◦ Electrical Analysis
◦ Turning Radius Report
Product Warranties (Exhibit C)
Dealer Supplied Products and/or Services (Exhibit D)

TABLE OF CONTENTS
1 2
3 4
5 goldenstatefire.com

11.4 JROGHQVWDWHĆUHFRP
PRODUCT 1 PROPOSAL

11.5 OPTION A
100% PRE-PAYMENT
This will be the price of the Product(s)
contingent upon the Customer paying the
Grand Total Purchase Price to GSFA within
thirty (30) calendar days of the Executed Date
pursuant to the Payment Terms
Please note this discount is also available contingent upon a Third Party (Leasing Company) paying 100% of the Grand Total Purchase Price on behalf of the Customer to GSFA within thirty (30) calendar days of the Executed Date pursuant to the Payment Terms

IF YOU ELECT THIS OPTION,

IT RESULTS IN A SAVINGS OF
($145,521.24) OFF

OF THE GRAND TOTAL OF OPTION B

11.6 goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
PRODUCT PROPOSAL FOR:

City of Santa Cruz
230 Walnut Avenue
Santa Cruz, CA 95060
Sales Consultant
Rich Myers
[email protected]
Mobile: (831) 251-8931
Golden State Fire Apparatus, Inc. (“GSFA”) is pleased to provide this proposal for the fire apparatus(es) and equipment identified below (the "Product”) to CITY OF SANTA CRUZ (“Customer”) for consideration. This proposal (this “Product Proposal”) includes the following exhibits attached hereto: the Standard Terms and Conditions attached as Exhibit A (the “Terms and Conditions”); the Product Specifications attached as Exhibit B (the “Specifications”); the Product Warranties attached as Exhibit C; and the Dealer Supplied Products and/or Services attached as Exhibit D (the “Dealer Supplied Products/Services List”) (all of the foregoing, collectively, the “Agreement”). Through its signature below or other Acceptance (as defined on page 2), Customer acknowledges having received and read, and agrees to be bound by, the Agreement. The Agreement shall be effective as of the latest date appearing in the signature blocks below (the “Executed Date”).

PAYMENT TERMS – Customer shall pay the total purchase price set forth directly above (the “Grand Total Purchase Price”) to GSFA within thirty (30) calendar days of the Executed Date. If payment of the Grand Total Purchase Price is late, a late fee as specified in section 6 of the Terms and Conditions may be applied, and the Prepayment Discount may be adjusted, and the Grand Total Purchase Price increased in accordance with section 2.c of the Terms and Conditions. Customer shall pay any balance due as a result of Change Orders as described in the Terms and Conditions.

MANUFACTURER – Customer acknowledges that GSFA is not an agent of the Product manufacturer identified above (“Manufacturer”) and is not capable of binding Manufacturer. Within five (5) business days of the Executed Date, GSFA shall submit an order form to the Manufacturer for the Product. GSFA’s further performance under the Agreement is contingent upon Manufacturer’s acceptance of such order form at the price and on the terms GSFA believed to be available when submitting this Product Proposal to Customer. If Manufacturer rejects such order as submitted or fails to respond to GSFA within a reasonable SUBMITTED DATE EXPIRATION DATE GSFA PROPOSAL # MANUFACTURER BID # MANUFACTURER CONSORTIUM 06/14/2024 08/02/2024 at 4:00
PM PST 70614-24A 955 Pierce Manufacturing Inc.

Sourcewell #113021-
OKC, ID #259,
Member # 26502

ITEM PRODUCT DESCRIPTION UNIT PRICE
A One (1) Pierce Manufacturing, Inc. Enforcer 1250 GPM Type 1 Engine 1,068,000.00 B Pre-Payment Discount for 100% Payment at Time of Order (the “Prepayment Discount”) (132,105.00) C SUBTOTAL 935,895.00
D 9.75% State Sales Tax 91,249.76
E California Tire Fee 10.50
F 100% Performance Bond 2,348.00
G GRAND TOTAL PURCHASE PRICE 1,029,503.26

11.7 goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
amount of time, GSFA shall notify Customer in writing, and unless GSFA and Customer otherwise agree in writing, the Agreement shall then terminate and have no further force or effect.

PRODUCT COMPLETION – The Product shall be ready for final inspection by Customer at the manufacturing facility within approximately 35.5 to 38.5 MONTHS after the Executed Date. The foregoing estimate is provided as a good faith approximation as of the date of submission of this Product Proposal and is subject to the Terms and Conditions.

PREDELIVERY SERVICE – If applicable, after transportation from the manufacturing facility and prior to final delivery or pick up, the Product shall receive those additional Products and/or services identified on the Dealer Supplied Products/Services List. It is estimated that such a service will add approximately 0.5 to 1 MONTH(S) to the above Product completion estimate. The foregoing estimate is provided as a good faith approximation as of the date of submission of this Product Proposal and is subject to the Terms and Conditions.

PROPOSAL EXPIRATION – This Product Proposal supersedes any previous proposal(s) presented to Customer by GSFA and its employees and may be accepted by Customer on or before the Expiration Date identified above. Unless accepted by the Expiration Date, GSFA reserves the right to withdraw this Product Proposal or to alter its terms (including by providing updated Product pricing) prior to an order being accepted.

PURCHASE ORDER – Any PO shall be made out to: Golden State Fire Apparatus, Inc. – 7400 Reese Road – Sacramento, CA 95828.

ACCEPTANCE – ACCEPTANCE OF THIS PROPOSAL CREATES AN ENFORCEABLE BINDING AGREEMENT BETWEEN GSFA AND CUSTOMER. “ACCEPTANCE” MEANS THAT THE CUSTOMER DELIVERS TO GSFA: (A) A SIGNED COPY OF THIS PRODUCT PROPOSAL, OR (B) A SIGNED COPY OF A PURCHASE ORDER INCORPORATING THE AGREEMENT IN ITS ENTIRETY. ANY ADDITIONAL OR DIFFERENT TERMS, WHETHER CONTAINED IN CUSTOMER’S FORMS OR OTHERWISE PRESENTED BY CUSTOMER AT ANY TIME, ARE HEREBY REJECTED AND OF NO EFFECT UNLESS APPROVED IN WRITING SIGNED BY GSFA.

COUNTERPARTS - This Product Proposal may be executed in multiple counterparts, each of which shall be deemed an original (including copies sent to a party by electronic transmission) as against the party signing such counterpart, but which together shall constitute one and the same instrument. A signed copy of this Product Proposal delivered by facsimile, email or other means of electronic transmission will be deemed to have the same legal effect as delivery of an original signed copy of this Product Proposal.

If this Product Proposal is returned to GSFA with the signature of Customer’s authorized representative but without an attestation or co-signers signature, then absent Customer’s written notice to the contrary, GSFA shall be entitled to rely on such single signature as sufficient evidence of the signatory’s authority to execute the Agreement and bind Customer thereby.

INTENDING TO CREATE A BINDING AGREEMENT, Customer and GSFA have each caused this Product Proposal dated 06/14/2024, GSFA Proposal Number 70614-24A to be executed by their duly authorized representatives effective as of the Executed Date.

ACCEPTED AND AGREED TO BY CUSTOMER ACCEPTED AND AGREED TO BY GSFA __________________________________________________ _________________________________________________ Signature of Authorized Customer Representative Signature of Authorized GSFA Representative

__________________________________________________ _________________________________________________ Print Name Print Name

__________________________________________________ _________________________________________________ Title Title

__________________________________________________ _________________________________________________ Date Date
Ryan Wright
President
July 31, 2024

11.8 OPTION B

PAYMENT AT TIME OF DELIVERY OR PICKUP
This will be the price of the Product(s) contingent
upon the Customer paying the Grand Total
Purchase Price to GSFA at time of delivery or pickup
pursuant to the Payment Terms

11.9 goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
PRODUCT PROPOSAL FOR:

City of Santa Cruz
230 Walnut Avenue
Santa Cruz, CA 95060
Sales Consultant
Rich Myers
[email protected]
Mobile: (831) 251-8931
Golden State Fire Apparatus, Inc. (“GSFA”) is pleased to provide this proposal for the fire apparatus(es) and equipment identified below (the "Product”) to CITY OF SANTA CRUZ (“Customer”) for consideration. This proposal (this “Product Proposal”) includes the following exhibits attached hereto: the Standard Terms and Conditions attached as Exhibit A (the “Terms and Conditions”); the Product Specifications attached as Exhibit B (the “Specifications”); the Product Warranties attached as Exhibit C; and the Dealer Supplied Products and/or Services attached as Exhibit D (the “Dealer Supplied Products/Services List”) (all of the foregoing, collectively, the “Agreement”). Through its signature below or other Acceptance (as defined on page 2), Customer acknowledges having received and read, and agrees to be bound by, the Agreement. The Agreement shall be effective as of the latest date appearing in the signature blocks below (the “Executed Date”).

PAYMENT TERMS – Customer shall pay the total purchase price set forth directly above (the “Grand Total Purchase Price”) to GSFA no later than the time of GSFA’s delivery of the applicable Product to Customer’s address listed above (or Customer’s pick up of such Product at GSFA’s facilities, if approved by GSFA). GSFA shall have no obligation to deliver, or permit pick up of the Product if the Customer does not have full payment ready when the Product is complete and ready to deliver or pick up, as applicable. Customer shall pay any balance due as a result of Change Orders as described in the Terms and Conditions.

MANUFACTURER – Customer acknowledges that GSFA is not an agent of the Product manufacturer identified above (“Manufacturer”) and is not capable of binding Manufacturer. Within five (5) business days of the Executed Date, GSFA shall submit an order form to the Manufacturer for the Product. GSFA’s further performance under the Agreement is contingent upon Manufacturer’s acceptance of such order form at the price and on the terms GSFA believed to be available when submitting this Product Proposal to Customer. If Manufacturer rejects such order as submitted or fails to respond to GSFA within a reasonable amount of time, GSFA shall notify Customer in writing, and unless GSFA and Customer otherwise agree in writing, the Agreement shall then terminate and have no further force or effect.

SUBMITTED DATE EXPIRATION DATE GSFA PROPOSAL # MANUFACTURER BID # MANUFACTURER CONSORTIUM 06/14/2024 08/02/2024 at 4:00
PM PST 70614-24B 955 Pierce Manufacturing Inc.

Sourcewell #113021-
OKC, ID #259,
Member # 26502

ITEM PRODUCT DESCRIPTION UNIT PRICE
A One (1) Pierce Manufacturing, Inc. Enforcer 1250 GPM Type 1 Engine 1,068,000.00 B 9.75% State Sales Tax 104,130.00
C California Tire Fee 10.50
D 100% Performance Bond 2,884.00
E GRAND TOTAL PURCHASE PRICE 1,175,024.50

11.10 goldenstatefire.com
7400 Reese Road, Sacramento, CA 95828 | 916.330.1638
PRODUCT COMPLETION – The Product shall be ready for final inspection by Customer at the manufacturing facility within approximately 35.5 to 38.5 MONTHS after the Executed Date. The foregoing estimate is provided as a good faith approximation as of the date of submission of this Product Proposal and is subject to the Terms and Conditions.

PREDELIVERY SERVICE – If applicable, after transportation from the manufacturing facility and prior to final delivery or pick up, the Product shall receive those additional Products and/or services identified on the Dealer Supplied Products/Services List. It is estimated that such a service will add approximately 0.5 to 1 MONTH(S) to the above Product completion estimate. The foregoing estimate is provided as a good faith approximation as of the date of submission of this Product Proposal and is subject to the Terms and Conditions.

PROPOSAL EXPIRATION – This Product Proposal supersedes any previous proposal(s) presented to Customer by GSFA and its employees and may be accepted by Customer on or before the Expiration Date identified above. Unless accepted by the Expiration Date, GSFA reserves the right to withdraw this Product Proposal or to alter its terms (including by providing updated Product pricing) prior to an order being accepted.

PURCHASE ORDER – Any PO shall be made out to: Golden State Fire Apparatus, Inc. – 7400 Reese Road – Sacramento, CA 95828.

ACCEPTANCE – ACCEPTANCE OF THIS PROPOSAL CREATES AN ENFORCEABLE BINDING AGREEMENT BETWEEN GSFA AND CUSTOMER. “ACCEPTANCE” MEANS THAT THE CUSTOMER DELIVERS TO GSFA: (A) A SIGNED COPY OF THIS PRODUCT PROPOSAL, OR (B) A SIGNED COPY OF A PURCHASE ORDER INCORPORATING THE AGREEMENT IN ITS ENTIRETY. ANY ADDITIONAL OR DIFFERENT TERMS, WHETHER CONTAINED IN CUSTOMER’S FORMS OR OTHERWISE PRESENTED BY CUSTOMER AT ANY TIME, ARE HEREBY REJECTED AND OF NO EFFECT UNLESS APPROVED IN WRITING SIGNED BY GSFA.

COUNTERPARTS - This Product Proposal may be executed in multiple counterparts, each of which shall be deemed an original (including copies sent to a party by electronic transmission) as against the party signing such counterpart, but which together shall constitute one and the same instrument. A signed copy of this Product Proposal delivered by facsimile, email or other means of electronic transmission will be deemed to have the same legal effect as delivery of an original signed copy of this Product Proposal.

If this Product Proposal is returned to GSFA with the signature of Customer’s authorized representative but without an attestation or co-signers signature, then absent Customer’s written notice to the contrary, GSFA shall be entitled to rely on such single signature as sufficient evidence of the signatory’s authority to execute the Agreement and bind Customer thereby.

INTENDING TO CREATE A BINDING AGREEMENT, Customer and GSFA have each caused this Product Proposal dated 06/14/2024, GSFA Proposal Number 70614-24B to be executed by their duly authorized representatives effective as of the Executed Date.

ACCEPTED AND AGREED TO BY CUSTOMER ACCEPTED AND AGREED TO BY GSFA __________________________________________________ _________________________________________________ Signature of Authorized Customer Representative Signature of Authorized GSFA Representative

__________________________________________________ _________________________________________________ Print Name Print Name

__________________________________________________ _________________________________________________ Title Title

__________________________________________________ _________________________________________________ Date Date

11.11 JROGHQVWDWHĆUHFRP

STANDARD TERMS

AND CONDITIONS
Exhibit “A”
2 11.12
1 STANDARD TERMS AND CONDITIONS

1. Definitions.

a. “Agreement” has the meaning given in the Product Proposal. b. “Customer” means the customer identified in the Product Proposal. c. “Dealer Preparation,” if applicable, means additional product(s) and/or services added by GSFA after Manufacturer’s completion of the Product and prior to delivery, in accordance with the Dealer Supplied Products/Services List.
d. “Delivery Date” means the Product Completion timeframe plus the Predelivery Service timeframe equals the Delivery Date.
e. “Dealer Supplied Products/Services List” means the Dealer Supplied Products and/or Services List attached to the Product Proposal as Exhibit D, which reflects all Dealer Preparation under the Agreement absent a valid Change Order(s).
f. “Grand Total Purchase Price” means the total purchase price for the Product identified in the Product Proposal (subject to any adjustments required or permitted by these Terms and Conditions, including by the execution of a valid Change Order(s).
g. “GSFA” means Golden State Fire Apparatus, Inc., a California corporation. h. “Manufacturer” means the person or persons, company, firm, corporation, partnership, or other organization identified in the Product Proposal as responsible for manufacturing the Product. i. “Party” or “Parties” means GSFA and/or Customer, as applicable. j. “Predelivery Service” means the Products and/or Services that will be provided by GSFA after transportation of the Product(s) from the manufacturing facility and prior to Final Delivery or Pick-Up. k. “Prepayment Discount” means a discount to the purchase price for the Product granted to Customer in connection with Customer’s advance payment of the Grand Total Purchase Price (or portion thereof, as specified in the Product Proposal).
l. “Product” means the fire apparatus(es) and any associated equipment listed in the Product Proposal and further described in the Specifications.
m. “Product Completion” means the fire apparatus(es) in the Product Proposal and further described in the Specifications being ready for final inspection by Customer at the manufacturing facility. n. “Product Proposal” means the GSFA proposal executed by Customer to which these Terms and Conditions are attached.
o. “Product Warranties” means the Manufacturer warranties for the Product attached to the Product Proposal as Exhibit C.
p. “Specifications” means the specifications for the Product attached to the Product Proposal as Exhibit B. q. “Terms and Conditions” means these Standard Terms and Conditions, which are attached to the Product Proposal as Exhibit A.

2. Purchase and Payment.
a. Purchase. Customer agrees to purchase the Product at the Grand Total Purchase Price (as such amount may be adjusted in accordance with these Terms and Conditions), pursuant to the payment terms set forth in the Product Proposal. The Grand Total Purchase Price is payable in U.S. dollars. b. Contingency Reserve Fund. The Grand Total Purchase Price may include an amount to be set aside for the purpose of funding any future costs or financial obligations incurred by Customer under the Product Proposal or any valid Change Order(s) (the “Contingency Reserve Fund”). If applicable, the amount of any required Contingency Reserve Fund will be set forth in either the Product Proposal or Exhibit D. The Contingency Reserve Fund may be withdrawn against by Customer or GSFA for the purpose of satisfying Customer’s payment obligations under the initial Product Proposal or any valid Change Order(s) (including, without limitation, a Change Order submitted by GSFA pursuant to Section 8.b). If a Contingency Reserve Fund is required under the Agreement, the amount of such fund is not intended as an estimate of the actual additional costs of contingencies, Change Orders, unforeseen items

11.13 2
or other required work that may be incurred under the Agreement after submission of the Product Proposal to Customer, which amounts Customer acknowledges may exceed the Contingency Reserve Fund amount. The balance of any Contingency Reserve Fund will be credited against Customer’s payment obligations, or otherwise returned to Customer within thirty (30) calendar days of delivery of all Products under the Agreement (provided that Customer has paid all amounts owed under the Agreement as of such date). c. Prepayment Discount. If GSFA has granted Customer a Prepayment Discount, Customer must provide each associated prepayment (each, a “Prepayment”) within the time frame specified in the Product Proposal in order to receive such discount. Customer’s failure to timely make such Prepayment may result in: (i) GSFA’s termination of the Agreement; and/or (ii) Customer’s loss of the Prepayment Discount for the portion of the Grand Total Purchase Price represented by such outstanding Prepayment and the application of a late fee as set forth in Section 6, in each case in GSFA’s sole discretion.
d. State Sales Tax. Customer shall be responsible for the cost of state sales tax associated with, or attributable to, the Product. The taxes stated in the Product Proposal are subject to adjustment for the applicable state sales tax rate in effect at the time of delivery. Therefore, the sales tax set forth on the Product Proposal is only an estimate of such taxes and will be increased or decreased at the time of delivery if a change in the applicable sales tax rate has occurred, in which case Customer shall pay GSFA (or be refunded by GSFA) the difference in the applicable sales tax.

3. Product Completion Date. Within thirty (30) calendar days of the date on which the last required signatory executes the Product Proposal (such date, the “Executed Date”), GSFA shall submit to Customer a tentative Product completion date (which may differ from the Product completion estimate contained in the Product Proposal). Due to global supply chain constraints, any Product completion date contained herein, or in the Product Proposal, or otherwise provided to Customer, is a good faith estimate only as of the date provided to Customer, and merely an approximation based on current information available to GSFA and Manufacturer. Customer shall not be entitled to rely on any such estimate, and GSFA shall have no liability to Customer for a failure by GSFA or Manufacturer to meet any such estimate. All Product completion estimates are subject to modification and, if applicable, GSFA will provide updates to such estimates to Customer when available.

4. Stock / Demo Units. Notwithstanding any other provision contained in the Agreement (including Section 12 hereof concerning warranties), any Products constituting stock/demo unit(s) are sold to Customer on an as-is, first-come and first served-basis and GSFA makes no further representation or warranty to any customer with respect to such unit(s). Regardless of the terms of the Product Proposal, GSFA shall only be obligated to sell such stock/demo unit(s) to the first customer to enter into a purchase agreement with GSFA identifying such unit(s), and after the execution by GSFA of such agreement any subsequent purchase agreement (including the Agreement, as applicable) shall have no further force or effect with respect to such unit(s).

5. Multiple Unit Purchase. If the Grand Total Purchase Price includes pricing for multiple Products, the Product price stated in the Product Proposal shall only be valid if the quantity of Products being proposed are purchased at the same time, pursuant to the same Agreement. GSFA shall have no obligation to offer the same price for any Product if purchased by Customer pursuant to a later purchase agreement.

6. Late Fee; Storage Fee. A late fee equal to 0.033% of the outstanding portion of the Grand Total Purchase Price will be charged per calendar day for overdue payments beginning ten (10) calendar days after the payment is due and continuing for the first thirty (30) calendar days thereafter. After such thirty (30) calendar day period, the late fee shall increase to 0.044% per calendar day until payment of the outstanding portion of the Grand Total Purchase Price is received. If Customer is unable to satisfy the delivery requirements hereunder or is unwilling to take delivery of the Product, then GSFA shall be entitled to a storage charge running from the earlier of: (i) the date of delivery agreed to between GSFA and Customer (provided GSFA is willing and able to deliver the Product on such date), or (ii) twenty-one (21) calendar days after GSFA notifies Customer that the Product is available for delivery. The storage charge is equal to: (i) $175.00 per calendar day per apparatus stored, or (ii) the actual charges incurred by GSFA with a third party for storage of the Product, whichever is greater. Such storage charge shall continue until the actual time

11.14 3
of delivery and Customer’s possession of the Product, and any such storage by GSFA or such third party shall be at the sole risk of Customer.

7. Delivery; Inspection and Acceptance.
a. Delivery. Subject to Section 5 hereof, the Product is scheduled to be delivered to the location and within the time period specified in the Product Proposal. Such delivery date is an estimate, and GSFA is, notwithstanding this Section 7.a, not bound to such date unless it otherwise agrees in a separate writing to complete delivery by a date certain. For the avoidance of doubt, GSFA is not responsible for delivery delays caused by or because of actions, omissions or conduct of Customer, the Manufacturer, or their respective employees, affiliates, suppliers, contractors, and carriers. Risk of loss for the Product shall pass to Customer at the point and time of delivery (which shall include an attempted delivery by GSFA which cannot be completed due to any act of Customer). However, title to the Product shall only pass to Customer upon delivery if Customer has then fully paid GSFA all amounts due hereunder (including additional amounts due under any valid Change Order). Absent GSFA’s separate written agreement, which it may or may not provide in its sole and absolute discretion, delivery of the Product will not occur before Customer has fully paid all amounts due under the Agreement and provided proof of insurance reasonably satisfactory to GSFA. If GSFA permits Customer to take possession of the Product, Customer may not mount equipment, conduct training, or place the Product into service until all amounts due under the Agreement have been paid. If Customer has ordered multiple Products, GSFA reserves the right to deliver such Products in installments and to separately invoice Customer for such Products.
b. Inspection and Acceptance. Upon delivery, Customer shall have ten (10) calendar days within which to inspect the Product for substantial conformance to the Specifications, and in the event of substantial nonconformance to the Specifications to furnish GSFA with written notice sufficient to permit GSFA to evaluate such non-conformance (“Notice of Nonconformance to Specifications”). Contingent upon part availability and Customer’s cooperation, any Product not in substantial conformance to material Specifications shall be remedied by GSFA (by repair or replacement, at GSFA’s election) within thirty (30) calendar days from GSFA’s receipt of the Notice of Nonconformance to Specifications. In the event GSFA does not receive a Notice of Nonconformance to Specifications within ten (10) calendar days of delivery, the Product will be deemed to be in conformance with Specifications and accepted by Customer.

8. Changes to Agreement Terms.
a. Change Orders. The Customer may request that GSFA incorporate a change to the Product or the Specifications for the Product, or GSFA may submit changes to the Agreement required or permitted to be made by GSFA (pursuant to Section 8.b or otherwise) by delivering a written Change Order to the other party hereto, which shall include a description of the proposed change sufficient to permit the receiving party to evaluate such change (either, a “Change Order”). For any Change Order submitted by Customer, GSFA will provide Customer a written response (a “Response”) stating (i) whether GSFA will accommodate such Change Order (which GSFA may decide in its sole and absolute discretion); and (ii) the terms of the modification to the order, including any increase or decrease in the Grand Total Purchase Price resulting from such Change Order, a date on which any increase in the Grand Total Purchase Price must be paid, and an estimate of any effect on production scheduling or delivery resulting from such Change Order. Customer shall have seven (7) calendar days after receipt of the Response to notify GSFA as to whether Customer desires to make the changes GSFA has approved in the Response. In the event Customer countersigns GSFA’s Response, Customer shall pay the increase (or be refunded the decrease) in the Grand Total Purchase Price by the date specified in the Response. GSFA may also send Customer a Change Order to account for any changes to the Agreement required or permitted to be made by GSFA (including those changes required pursuant to Section 8.b hereof), and such Change Order shall be effective upon delivery to Customer unless Customer elects to terminate the applicable Product order under the Agreement in accordance with Section 9.

11.15 4
b. Additional Changes.
i. Component Price Volatility; Increases Imposed by Manufacturer. GSFA shall not be responsible for (i) any unforeseen price increase or surcharge enacted by suppliers of major components of the Product (including but not limited to commercial chassis, engine, transmission, and fire pump); or (ii) price increases imposed on GSFA by Manufacturer pursuant to Manufacturer’s terms and conditions for sale of the Product (a “Manufacturer Price Increase”), after Customer becomes bound by the Agreement. Customer shall be responsible for all amounts arising from any price increases for major components of the Product (including all associated taxes and fees thereon) for the Product or any Manufacturer Price Increases occurring after the execution of the Agreement which increases the cost of the Product to GSFA, and such amounts will be documented on a Change Order adjusting the Grand Total Purchase Price accordingly. Customer shall pay any such price increase prior to Product delivery. A Manufacturer Price Increase may include, but shall not be limited to, an increase in Product price resulting from an increase in the Producer Price Index of Components for Manufacturing (see www.bls.gov Series ID: WPUID6112) in excess of a compounded annual growth rate of five percent (5%), as measured between the month Manufacturer accepts the applicable Product order and the month that is fourteen (14) months prior to the then-current estimated Product completion date (the foregoing, a “PPI-Based Price Increase”). If, upon Customer’s receipt of a Change Order reflecting a PPI-Based Price Increase, Customer elects to terminate the applicable Product Order in accordance with Section 8.b.iii rather than pay such increase, then in lieu of the cancellation fees described in Section 9.a hereof GSFA shall be entitled to recover and Customer shall pay GSFA’s actual non-reimbursable costs incurred in connection with the Product order through the date of Customer’s termination of such Product order. ii. New Legal Standards. In the event the Product design, materials or specifications require an alteration arising from new regulations issued by any governmental entity or trade association, including, but not limited to, the NFPA, DOT, and EPA, and such alteration increases the cost of the Product to GSFA, Customer shall be responsible for changes to the Grand Total Purchase Price arising from such alteration. GSFA shall promptly notify Customer when it becomes aware of any potential or required change in regulations occurring prior to delivery that would impact the Product purchased.
iii. Change Orders. Customer shall execute any Change Order submitted by GSFA documenting any of the changes required or permitted by Sections 8.b.i and 8.b.ii above (which shall, to the extent practicable, itemize any increases in the Grant Total Purchase Price and specify a commercially reasonable date by which Customer must pay such increase), unless Customer instead elects to terminate the applicable Product order under the Agreement within fifteen (15) calendar days of Customer’s receipt of such Change Order and in accordance with Section 9.

Absent such a termination, failure to execute a Change Order does not alter Customer’s obligations under this Section 8.b.
c. Changes in Commercial Specifications. Specifications for all components of the Product manufactured by companies other than the Manufacturer are subject to change without notice. Specifications for such components will be as available at the time of manufacture of the Product. GSFA shall not be liable for any deviations in such specifications arising from a substitution of components or changes in the design of any component by their original manufacturer.

9. Termination.
a. By Customer. Customer may terminate a Product order identified in the Product Proposal or a Change Order by providing written notice to GSFA in accordance with Section 16 hereof. If Customer elects to terminate a Product order, Customer shall pay GSFA a cancellation fee as follows: (a) after the Product order is accepted and entered by GSFA, 10% of the portion of the Grand Total Purchase Price applicable to such Product (including all associated taxes, fees and costs) (such amount, the “Product Purchase Price”); (b) after completion of the preconstruction phase of the order process, 20% of the Product Purchase Price; and (c) after the requisition of any materials or commencement of any manufacturing or assembly of the Product by either GSFA or Manufacturer but before substantial completion of such Product, 50% of the Product Purchase Price. Customer shall not be permitted to terminate a Product order after substantial completion of manufacturing and assembly of such Product (excluding

11.16 5
any Dealer Preparation or other pre-delivery services or untypical Product customization, if applicable).

Notwithstanding the foregoing, if the applicable tier of cancellation fee is not sufficient to cover all actual costs and fees incurred by GSFA with Manufacturer in connection with Customer’s termination of the Product order (“Manufacturer Termination Fees”), then in addition to such cancellation fee Customer shall pay the balance of all Manufacturer Termination Fees. If Customer received a Prepayment Discount, such discount shall not be considered for the purpose of calculating the above cancellation fee. The tier of cancellation fee applicable to any cancellation, as well as the determination of whether a Product has reached substantial completion, shall be in the sole and absolute discretion of GSFA. Customer may request a fee waiver, and GSFA, in its sole discretion, may agree to waive and/or adjust such fee. GSFA will return the balance of the Grand Total Purchase Price or Product Purchase Price, as applicable, within thirty (30) calendar days of the effective date of the cancellation of the Product order or termination of the Agreement.

Customer may terminate the Agreement for an Event of Default by GSFA after providing GSFA with written notice in accordance with Section 16 (which notice shall describe with reasonably particularity the Event of Default justifying such termination) if such Event of Default remains uncured (if capable of cure) thirty (30) days following GSFA’s receipt of such notice; provided, however, that the foregoing cure period shall continue if and for so long as GSFA has commenced and is continuing to undertake commercially reasonable efforts to cure such Event of Default as promptly as reasonably practicable.
b. By GSFA. GSFA may terminate the Agreement for an Event of Default by Customer after providing Customer with written notice in accordance with Section 16 (which notice shall describe with reasonably particularity the Event of Default justifying such termination) if such Event of Default remains uncured (if capable of cure) thirty (30) days following Customer’s receipt of such notice; provided, however, that the foregoing cure period shall continue if and for so long as Customer has commenced and is continuing to undertake commercially reasonable efforts to cure such Event of Default as promptly as reasonably practicable. Notwithstanding the foregoing, GSFA may terminate the Agreement effective immediately upon written notice to Customer for Customer’s failure to pay any amount owed under the Agreement when due.

Notwithstanding any other provision of this Agreement, if Customer terminates a Product order in accordance with Section 9.a above, GSFA may elect to instead terminate the Agreement upon notice to Customer in accordance with Section 16 hereof. If GSFA terminates the Agreement in accordance with this Section 9.b, Customer shall pay the applicable tier of cancellation fee for all Products pursuant to Section 9.a above as if Customer had elected to terminate each applicable Product order.
c. Based on Discontinuation or Cancellation by Manufacturer. In the event that Manufacturer cancels a Product order (provided that such cancellation is not the result of an act by Customer in violation of the Agreement) or discontinues the manufacture of a Product prior to its completion and delivery: (i) if such Product is the only Product contemplated under the Agreement, then the Agreement shall terminate; or (ii) if additional Products are contemplated under the Agreement, then only the Product order for the applicable cancelled or discontinued Product shall be terminated. Such Agreement termination or Product termination, as applicable, shall be effective upon GSFA’s written notice to Customer of such cancellation or discontinuance in accordance with Section 16 hereof.

GSFA’s only obligation to Customer in such event shall be the return of any Prepayment paid by Customer for the cancelled or discontinued Product. For the avoidance of doubt, the cancellation fees contemplated in Section 9.a hereof shall not apply in the event of a termination pursuant to this Section 9.c.

10. Customer’s Obligations. Customer shall provide its timely and best efforts to cooperate with GSFA and Manufacturer during the Product manufacturing process. Reasonable and timely cooperation includes, without limitation, Customer’s providing timely information in response to any requests from Manufacturer or GSFA and the participation of Customer’s authorized representatives in traveling to Manufacturer’s facility for inspections and approval of the Product, including a final approval before the Product leaves Manufacturer’s facility.

11. Representations and Warranties. Customer hereby represents and warrants to GSFA as of the Executed Date that the execution of the Agreement and the purchase of the Product(s) and performance of the other obligations

11.17 6
of Customer under the Agreement have been approved by Customer in accordance with applicable general laws and, as applicable, Customer’s charter, ordinances, purchasing policies, and other governing documents, and executed by the appropriate Customer employees, officials, and/or representatives, and funding for Customer’s performance of its obligations under the Agreement has been duly budgeted and appropriated by Customer.

12. Standard Warranty. All applicable Manufacturer warranties are contained in the Product Warranties. Any additional warranties must be expressly approved in a writing signed by GSFA, and Customer acknowledges and agrees that Manufacturer will not be liable for any such additional warranties. a. Disclaimer. OTHER THAN AS EXPRESSLY SET FORTH IN THE AGREEMENT, GSFA, ITS AFFILIATES, AND THEIR

RESPECTIVE OFFICERS, DIRECTORS, EMPLOYEES, SHAREHOLDERS, AGENTS, OR REPRESENTATIVES, DO NOT MAKE

ANY EXPRESS OR IMPLIED WARRANTIES WITH RESPECT TO THE PRODUCT (WHETHER RELATING TO THE CONDITION

OR QUALITY OF THE PRODUCT, OR OTHERWISE) PROVIDED HEREUNDER OR OTHERWISE REGARDING THE

AGREEMENT (INCLUDING, WITHOUT LIMITATION, WITH RESPECT TO ANY APPLICABLE DEALER PREPARATION), WHETHER ORAL OR WRITTEN, EXPRESS, IMPLIED OR STATUTORY. WITHOUT LIMITING THE FOREGOING, ANY

IMPLIED WARRANTY OR CONDITION OF MERCHANTABILITY, THE IMPLIED WARRANTY AGAINST INFRINGEMENT, THE

IMPLIED WARRANTY OR CONDITION OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY IMPLIED WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE ARE EXPRESSLY EXCLUDED AND DISCLAIMED.

STATEMENTS MADE BY SALES CONSULTANTS OR IN PROMOTIONAL MATERIALS DO NOT CONSTITUTE WARRANTIES. b. Exclusions of Incidental and Consequential Damages. In no event shall GSFA be liable for consequential, incidental, or punitive damages incurred by Customer in connection with any matter arising out of or relating to the Agreement, or the breach thereof, even if GSFA has been advised of the possibility of such damages, and regardless of whether such damages arise out of breach of warranty, the Agreement, indemnity, whether resulting from nondelivery or from GSFA’s own negligence, or otherwise, except and solely to the extent such damages arise from the gross negligence or willful misconduct of GSFA.

13. Default. The occurrence of one or more of the following events (each, an “Event of Default”) shall constitute a default under the Agreement: (a) Customer’s failure to pay any amounts due or to perform any of its obligations under the Agreement; (b) GSFA’s failure to perform any of its obligations under the Agreement; (c) either Party becoming insolvent or becoming subject to bankruptcy or insolvency proceedings; (d) any representation made by either Party under the Agreement which is false in any material respect; (e) any action by Customer to dissolve, merge, consolidate or transfer a substantial portion of its property to another entity during the term of the Agreement; (f) any other material breach of the terms of the Agreement by a Party; or (g) a default or breach by Customer under any other agreement with GSFA or its affiliates.

14. Indemnification of GSFA. Customer shall indemnify, defend, and hold harmless GSFA, its agents, servants, successors and assigns from and against all losses, damages, injuries, claims, demands and expenses, including attorneys’ fees and other legal expenses, of whatever nature (“Damages”), to the extent Damages arise out of or in connection with: (i) Customer’s breach of the Agreement, or (ii) Customer’s use, storage, or operation of the Product following delivery, regardless of where, how, and by whom operated (excluding any negligent operation by GSFA).

The indemnification and assumptions of liability and obligation herein provided shall continue in full force and effect notwithstanding the termination of the Agreement, whether by expiration of time, by operation of law or otherwise.

This provision is not intended to and shall not constitute the exclusive remedy of the Parties under the Agreement; the Parties may seek indemnity from one another under other legal principles, whether based in equity or law, so long as they do not nullify or cancel the effects of this paragraph.

15. Force Majeure. GSFA shall not be responsible nor deemed to be in default of any provision of the Agreement on account of delays in performance due to causes which are beyond GSFA’s or Manufacturer’s control and which make GSFA’s performance impracticable, including but not limited to wars, insurrections, strikes or labor unrest, riots, fires, storms, floods, other acts of nature, explosions, earthquakes, accidents, any act of federal, state or local government, failure or delays in transportation, inability to obtain necessary labor, supplies or manufacturing facilities, supply chain issues, allocation regulations or orders affecting materials, equipment, facilities or completed

11.18 7
products, failure to obtain any required license or certificates, acts of God or the public enemy or terrorism, failure of transportation, disease, pandemics or epidemics, quarantine restrictions, failure of vendors (due to causes similar to those within the scope of this clause) to perform their agreements or labor troubles causing cessation, slowdown, or interruption of work.

16. Notice. Any notices, requests, consents, claims, demands, waivers and other communications required or permitted to be given hereunder must be given in writing at the address of each Party set forth below, or to such other address as either Party may substitute by written notice to the other in accordance with this Section 16, by one of the following methods: hand delivery; registered, express, or certified mail, return receipt requested, postage prepaid; or nationally recognized private express courier. All such communications will be deemed to have been given: (i) when delivered by hand (with written confirmation of receipt); (ii) on the third (3rd) calendar day after the date mailed, by registered, express or certified mail; or (iii) when delivered by the addressee if sent by a nationally recognized private express courier.

GSFA: CUSTOMER:

Golden State Fire Apparatus Inc. To the address listed in the Product Proposal 7400 Reese Road
Sacramento, CA 95828

17. Contradictions. In the event of a conflict between the Agreement and any Change Order, or between Change Orders, the terms of the latest executed Change Order shall control.

18. Manufacturer’s Statement of Origin. It is agreed that the manufacturer’s statement of origin (“MSO”) for the Product covered by the Agreement, if applicable, shall be retained and remain in the possession of GSFA per California Department of Vehicles (DMV) directives. Notwithstanding the foregoing, GSFA shall provide Customer with the original MSO if the Customer is self-registering, and Customer shall comply with all good-faith Process of Duty and other DMV requirements applicable to the Product and retain its own MSO.

19. Assignment. The relationship of the Parties established under the Agreement is that of independent contractors and neither Party is a partner, employee, agent, or joint venturer of or with the other. Neither Party may assign its rights and obligations under the Agreement unless it has obtained the prior written approval of the other Party.

20. Governing Law; Jurisdiction; Disputes. Without regard to any conflict of laws provisions, the Agreement is to be governed by and under the laws of the state of California. Prior to taking any legal action that may and/or can arise out of the Agreement, the Parties shall first attempt mediation with an agreed upon mediator. If the Parties cannot agree upon a mediator within thirty (30) calendar days of the submission of written notice of a dispute in accordance with Section 16 hereof, if any disputed matter remain unresolved within thirty (30) calendar days of the commencement of discussions, or if any party refuses to meet, then either party may submit any remaining disputes concerning and/or claim regarding the Agreement and/or the terms and conditions herein to the Superior Court, County of Sacramento (and the parties expressly consent to exclusive personal jurisdiction and venue before such court).

21. Entire Agreement; Amendments. The Agreement, including the Product Proposal, its exhibits, and all valid Change Orders, is the exclusive agreement between the Parties regarding the subject matter contained herein and therein. No change in, modification of, or revision of the Agreement shall be valid unless in writing and signed by duly authorized representatives of both Parties with authority to sign such amendments to the Agreement.

END OF STANDARD TERMS AND CONDITIONS

11.19 JROGHQVWDWHĆUHFRP

PRODUCT

SPECIFICATIONS
Exhibit “B”
3 11.20
Proposal Details Report
OptionCode Type Option ProposalText
0766611 Boiler Plates, Pumper

GSFA is pleased to submit a proposal to the City of Santa Cruz Fire Department for a Pierce® triple combination pumper per your request for quotation. The following paragraphs will describe in detail the apparatus, construction methods, and equipment proposed. This proposal will indicate size, type, model and make of components parts and equipment, providing proof of compliance with each and every item (except where noted) in the departments advertised specifications.

PIERCE MANUFACTURING was founded in 1913. Since then we have been building bodies with one philosophy, "BUILD THE FINEST". Our skilled craftsmen take pride in their work, which is reflected, in the final product. We have been building fire apparatus since the early "forties" giving Pierce Manufacturing over 75 years of experience in the fire apparatus market. Pierce Manufacturing has built and put into service more than 62,500 apparatus, including more than 33,900 on Pierce custom chassis designed and built specifically for fire and emergency applications. Our Appleton, Wisconsin facility has over 870,000 total square feet of floor space situated on approximately 105 acres of land. Our Bradenton, Florida facility has 300,000 square feet of floor space situated on approximately 38 acres of land.

Our beliefs in high ethical standards are carried through in all of our commitments and to everyone with whom we do business. Honesty, Integrity, Accountability and Citizenship are global tenets by which we all live and work. Consequently, we neither engage in, nor have we ever been convicted of price fixing, bid rigging, or collusion in any domestic or international fire apparatus market.

Pierce has only one brand of fire apparatus "Pierce", ensuring you are receiving top of the line product that meets your specification.

In accordance with the current edition of applicable NFPA standards, this proposal will specify whether the fire department, manufacturer, or apparatus dealership will provide required loose equipment.

Images and illustrative material in this proposal are as accurate as known at the time of publication, but are subject to change without notice. Images and illustrative material is for reference only, and may include optional equipment and accessories and may not include all standard equipment.

GENERAL DESIGN AND CONSTRUCTION
To control quality, ensure compatibility, and provide a single source for service and warranty, the custom cab, chassis, pump module and body will be entirely designed, assembled/welded and painted in Pierce owned manufacturing facilities. This includes, but not limited to the cab weldment, the pumphouse module assembly, the chassis assembly, the body and the electrical system.

QUALITY AND WORKMANSHIP
Pierce has set the pace for quality and workmanship in the fire apparatus field. Our tradition of building the highest quality units with craftsmen second to none has been the rule right from the beginning and we demonstrate that ongoing commitment by: Ensuring all steel welding follows American Welding Society D1.1-2004 recommendations for structural steel welding. All aluminum welding follows American Welding society and ANSI D1.2-2003 requirements for structural welding of aluminum. All sheet metal welding follows American welding Society B2.1-2000 requirements for structural welding of sheet metal. Our flux core arc welding uses alloy rods, type 7000 and is performed to American Welding Society standards A5.20-E70T1. Furthermore, all employees classified as welders are tested and certified to meet the American welding Society codes upon hire and every three (3) years thereafter. Pierce also employs and American Welding Society certified welding inspector in plant during working hours to monitor weld quality.

Pierce Manufacturing operates a Quality Management System under the requirements of ISO 9001. These standards sponsored by the International Organization for Standardization (ISO) specify the quality systems that are established by the manufacturer for design, manufacture, installation and service. A copy of the certificate of compliance is included with this proposal.

In addition to the Quality Management system, we also employ a Quality Achievement Supplier program to ensure the vendors and suppliers that we utilize meet the high standards we demand.

That is just part of our overall "Quality at the Source" program at Pierce.

To demonstrate the quality of our products and services, a list of at least twenty (20) fire departments/municipalities that have purchased vehicles for a second time is provided.

DELIVERY
The apparatus will be delivered under its own power to ensure proper break-in of all components while the apparatus is still under warranty. A qualified delivery representative shall deliver the apparatus and remain for a sufficient length of time to instruct personnel in proper operation, care and maintenance of the equipment delivered.

MANUAL AND SERVICE INFORMATION
At time of delivery, complete operation and maintenance manuals covering the apparatus will be provided. A permanent plate will be mounted in the driver's compartment specifying the quantity and type of fluids required including engine oil, engine coolant, transmission, pump transmission lubrication, pump primer and drive axle.

SAFETY VIDEO
At the time of delivery Pierce will also provide one (1) 39-minute, professionally produced apparatus safety video, in DVD format. A link to the video is also available on the Pierce Training website. This video will address key safety considerations for personnel to follow when they are driving, operating, and maintaining the apparatus, including the following: vehicle pre-trip inspection, chassis operation, pump operation, aerial operation, and safety during maintenance.

PERFORMANCE TESTS
6/10/2024
Customer: CITY OF SANTA CRUZ FIRE
DEPT
Bid Number: 955
Representative Myers, Rich Job Number:

Requirements Manager: Organization: Golden State Fire Apparatus, Inc Description: Santa Cruz FD 1500 gpm Pump
Chassis: Enforcer Chassis
Body: Pumper, Medium, Aluminum, 2nd Gen
Bid #: 955 1

11.21 A road test will be conducted with the apparatus fully loaded and a continuous run of no less than ten (10) miles. During that time the apparatus will show no loss of power nor will it overheat. The transmission drive shaft or shafts and the axles will run quietly and be free of abnormal vibration or noise. The apparatus when fully loaded will not have less than 25 percent nor more than 50 percent on the front axle, and not less than 50 percent nor more than 75 percent on the rear axle.

The apparatus will meet the current edition of applicable NFPA standards acceleration and braking requirements.

SERVICE AND WARRANTY SUPPORT
Pierce dealership support will be provided by GSEVS by operating a Pierce authorized service center. The service center will have factory-trained mechanics on staff versed in Pierce fire apparatus. The service facility will be located within one hundred (100) miles of the fire department.

In addition to the dealership, Pierce has service facilities located in both, Weyauwega, Wisconsin and Bradenton, Florida. Pierce also maintains a dedicated parts facility of over 100,000 square feet in Appleton, Wisconsin. The parts facility stocks in excess of $5,000,000 in parts dedicated to service and replacement parts. The parts facility employs a staff dedicated solely for the distribution and shipment of service and replacement parts.

Service parts for the apparatus being proposed can be found via Pierceparts.com which, is an interactive online tool that delivers information regarding your specific apparatus as well as the opportunity to register for training classes.

As a Pierce customer you have the ability to view the complete bill of materials for your specific apparatus, including assembly drawings, piece part drawings, and beneficial parts notations. You will also have the ability to search the complete Pierce item master through a parts search function which offers all Pierce SKU's and descriptions offered on all Pierce apparatus. Published component catalogs, which include proprietary systems along with an extensive operator's manual library is available for easy reference.

Pierce Manufacturing maintains a dedicated service and warranty staff of over 35 personnel, dedicated to customer support, which also maintains a 24 hour 7 day a week toll free hot line, four (4) on staff EVTs, and offers hands-on repair and maintenance training classes multiple times a year.

LIABILITY
The successful bidder will defend any and all suits and assume all liability for the use of any patented process including any device or article forming a part of the apparatus or any appliance furnished under the contract.

INSURANCE PROVIDED BY BIDDER

COMMERCIAL GENERAL LIABILITY INSURANCE
The successful bidder will, during the performance of the contract and for three (3) years following acceptance of the product, keep in force at least the following minimum limits of commercial general liability insurance:

Each Occurrence $1,000,000
Products/Completed Operations Aggregate $1,000,000
Personal and Advertising Injury $1,000,000
General Aggregate $2,000,000
Coverage will be written on a Commercial General Liability form. The policy will be written on an occurrence form and will include Contractual Liability coverage for bodily injury and property damage subject to the terms and conditions of the policy. The policy will include Owner as an additional insured when required by written contract.

COMMERCIAL AUTOMOBILE LIABILITY INSURANCE
The successful bidder will, during the performance of the contract, keep in force at least the following minimum limits of commercial automobile liability insurance and coverage will be written on a Commercial Automobile liability form:

Each Accident Combined Single Limit: $1,000,000

UMBRELLA/EXCESS LIABILITY INSURANCE
The successful bidder will, during the performance of the contract and for three (3) years following acceptance of the product, keep in force at least the following minimum limits of umbrella liability insurance:

Aggregate: $3,000,000
Each Occurrence: $3,000,000
The umbrella policy will be written on an occurrence basis and at a minimum provide excess to the bidder's General Liability and Automobile Liability policies.

The required limits can be provided by one (1) or more policies provided all other insurance requirements are met.

Coverage will be provided by a carrier(s) rated A- or better by A.M. Best.

All policies will provide a 30-day notice of cancellation to the named insured. The Certificate of Insurance will provide the following cancellation clause: Should any of the above described polices be cancelled before the expiration date thereof, notice will be delivered in accordance with the policy provisions.

Bidder agrees to furnish owner with a current Certificate of Insurance with the coverages listed above along with the bid. The certificate will show the purchaser as certificate holder.

INSURANCE PROVIDED BY MANUFACTURER

PRODUCT LIABILITY INSURANCE
The manufacturer will, during the performance of the contract and for three (3) years following acceptance of the product, keep in force at least the following minimum limits of Product Liability insurance:

Each Occurrence $1,000,000
Products/Completed Operations Aggregate $1,000,000
Coverage will be written on a Commercial General Liability form. The policy will be written on an occurrence form. The manufacturer's policy will include the owner as additional insured when required by written contract between the Owner and a Pierce authorized dealer.

UMBRELLA/EXCESS LIABILITY INSURANCE
The manufacturer will, during the performance of the contract and for three (3) years following acceptance of the product, keep in force at least the following minimum limits of umbrella liability insurance:

Each Occurrence: $25,000,000
Aggregate: $25,000,000
The umbrella policy will be written on an occurrence basis and provide excess to the manufacturer's General Liability/Products policies.

Bid #: 955 2

11.22 The required limits can be provided by one (1) or more policies provided all other insurance requirements are met.

Coverage will be provided by a carrier(s) rated A- or better by A.M. Best.

All policies will provide a 30-day notice of cancellation to the named insured. The Certificate of Insurance will provide the following cancellation clause: Should any of the above described polices be cancelled before the expiration date thereof, notice will be delivered in accordance with the policy provisions.

Manufacturer agrees to furnish owner with a current Certificate of Insurance with the coverages listed above along with the bid. The certificate will show the purchaser as the certificate holder. 0661794 Single Source Compliance

SINGLE SOURCE MANUFACTURER
Pierce Manufacturing, Inc. provides an integrated approach to the design and manufacture of our products that delivers superior apparatus and a dedicated support team. From our facilities, the chassis, cab weldment, cab, pumphouse (including the sheet metal enclosure, valve controls, piping and operators panel) and body will be entirely designed, tested, and hand assembled to the customer's exact specifications. The electrical system either hardwired or multiplexed, will be both designed and integrated by Pierce Manufacturing. The warranties relative to these major components (excluding component warranties such as engine, transmission, axles, pump, etc.) will be provided by Pierce as a single source manufacturer. Pierce's single source solution adds value by providing a fully engineered product that offers durability, reliability, maintainability, performance, and a high level of quality.
0584456 Manufacture Location, Appleton,
Wisconsin
Your apparatus will be manufactured in Appleton, Wisconsin. 0584452 RFP Location: Appleton, Wisconsin

0588609 Vehicle Destination, US
0816491 Comply NFPA 1900 Changes
Effective Jan 1, 2024, With
Exceptions
NFPA 2024 STANDARDS
This unit will comply with the NFPA standards effective January 1, 2024, except for fire department directed exceptions. These exceptions will be set forth in the Statement of Exceptions.

Certification of slip resistance of all stepping, standing and walking surfaces will be supplied with delivery of the apparatus.

All horizontal surfaces designated as a standing or walking surface that are greater than 48.00" above the ground must be defined by a 1.00" wide line along its outside perimeter. Perimeter markings and designated access paths to destination points will be identified on the customer approval print and are shown as approximate. Actual location(s) will be determined based on materials used and actual conditions at final build. Access paths may pass through hose storage areas and opening or removal of covers or restraints may be required. Access paths may require the operation of devices and equipment such as the aerial device or ladder rack.

A plate that is highly visible to the driver while seated will be provided. This plate will show the overall height, length, and gross vehicle weight rating.

The manufacturer will have programs in place for training, proficiency testing and performance for any staff involved with certifications.

An official of the company will designate, in writing, who is qualified to witness and certify test results.
0533347 Pumper/Pumper with Aerial Device
Fire Apparatus
0588611 Vehicle Certification, Pumper

0661778 Agency, Apparatus Certification,
Pumper/Tanker, U.L.

NFPA COMPLIANCY
Apparatus proposed by the bidder will meet the applicable requirements of the National Fire Protection Association (NFPA) as stated in current edition at time of contract execution. Fire department's specifications that differ from NFPA specifications will be indicated in the proposal as "non-NFPA".

PUMP TEST
Underwriters Laboratory (UL) will test, approved, and certify the pump. The test results and the pump manufacturer's certification of hydrostatic test; the engine manufacturer's certified brake horsepower curve; and the pump manufacturer's record of pump construction details will be forwarded to the Fire Department.

GENERATOR TEST
If the unit has a generator, Underwriters Laboratory (UL) will test, approved, and certify the generator. The test results will be provided to the Fire Department at the time of delivery.

BREATHING AIR TEST
If the unit has breathing air, Pierce Manufacturing will draw an air sample from the air system and have the sample certified that the air quality meets the requirements of NFPA 1989, Standard on Breathing Air Quality for Fire and Emergency Services Respiratory Protection.

Bid #: 955 3

11.23 0816495 Certification, Vehicle Inspection
Program, NFPA 1900

VEHICLE INSPECTION PROGRAM CERTIFICATION
To assure the vehicle is built to current NFPA 1900 standards, the apparatus, in its entirety, will be third-party, independent, audit-certified through Underwriters Laboratory (UL) that it is built and complies to all applicable standards in the current edition. The certification includes: all design, production, operational, and performance testing of not only the apparatus, but those components that are installed on the apparatus.

A placard will be affixed in the driver's side area stating the third party agency, the date, the standard and the certificate number of the whole vehicle audit. 0766110 Consortium, Sourcewell

0537375 Unit of Measure, US Gallons

0030006 Bid Bond Not Requested

BID BOND NOT REQUESTED
A bid bond will not be included. If requested, the following will apply:

All bidders will provide a bid bond as security for the bid in the form of a 5 percent bid bond to accompany their bid. This bid bond will be issued by a Surety Company who is listed on the U.S.

Treasury Departments list of acceptable sureties as published in Department Circular 570. The bid bond will be issued by an authorized representative of the Surety Company and will be accompanied by a certified power of attorney dated on or before the date of bid. The bid bond will include language, which assures that the bidder/principal will give a bond or bonds as may be specified in the bidding or contract documents, with good and sufficient surety for the faithful performance of the contract, including the Basic One (1) Year Limited Warranty, and for the prompt payment of labor and material furnished in the prosecution of the contract.

Notwithstanding any document or assertion to the contrary, any surety bond related to the sale of a vehicle will apply only to the Basic One (1) Year Limited Warranty for such vehicle. Any surety bond related to the sale of a vehicle will not apply to any other warranties that are included within this bid (OEM or otherwise) or to the warranties (if any) of any third party of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. In the event of any contradiction or inconsistency between this provision and any other document or assertion, this provision will prevail.
0816571 Performance Bond, 100% with 25%
Warranty Bond, 1 Yr, and Payment
Bond, PPI Terms
PERFORMANCE BOND, 1 YEAR
The successful bidder will furnish a Performance and Payment bond (Bond) equal to 100 percent of the total contract amount within 30 days of the notice of award. Such Bond will be in a form acceptable to the Owner and issued by a surety company included within the Department of Treasury's Listing of Approved Sureties (Department Circular 570) with a minimum A.M. Best Financial Strength Rating of A and Size Category of XV. In the event of a bond issued by a surety of a lesser Size Category, a minimum Financial Strength rating of A+ is required.

Bidder and Bidder's surety agree that the Bond issued hereunder, whether expressly stated or not, also includes the surety's guarantee of the vehicle manufacturer's Basic One (1) Year Limited Warranty period included within this proposal. Owner agrees that the penal amount of this bond will be simultaneously amended to 25 percent of the total contract amount upon satisfactory acceptance and delivery of the vehicle(s) included herein. Notwithstanding anything contained within this contract to the contrary, the surety's liability for any warranties of any type will not exceed one (1) year from the date of such satisfactory acceptance and delivery, or the actual Basic One (1) Year Limited Warranty period, whichever is shorter.

Due to global supply chain constraints, any delivery date contained herein is a good faith estimate as of the date of this order/contract, and merely an approximation based on current information. Delivery updates will be made available, and a final firm delivery date will be provided as soon as possible.

If the Producer Price Index of Components for Manufacturing [www.bls.gov Series ID:

WPUID6112] ("PPI") has increased at a compounded annual growth rate of 5.0% or more between the month Pierce accepts the order ("Order Month") and a month 14 months prior to the then predicted Ready For Pickup date ("Evaluation Month"), then pricing may be updated in an amount equal to the increase in PPI over 5.0% for each year or fractional year between the Order Month and the Evaluation Month.

The seller will document any such updated price for the customer's approval before proceeding and provide an option to cancel the order.
0000007 Approval Drawing APPROVAL DRAWING
A drawing of the proposed apparatus will be prepared and provided to the purchaser for approval before construction begins. The Pierce sales representative will also be provided with a copy of the same drawing. The finalized and approved drawing will become part of the contract documents. This drawing will indicate the chassis make and model, location of the lights, siren, horns, compartments, major components, etc.

A "revised" approval drawing of the apparatus will be prepared and submitted by Pierce to the purchaser showing any changes made to the approval drawing. 0002928 Electrical Diagrams ELECTRICAL WIRING DIAGRAMS
Two (2) electrical wiring diagrams, prepared for the model of chassis and body, will be provided.

Bid #: 955 4

11.24 0649754 Enforcer Chassis

ENFORCER CHASSIS
The Pierce Enforcer™ is the custom chassis developed exclusively for the fire service. Chassis provided will be a new, tilt-type custom fire apparatus. The chassis will be manufactured in the apparatus body builder's facility eliminating any split responsibility. The chassis will be designed and manufactured for heavy-duty service, with adequate strength, capacity for the intended load to be sustained, and the type of service required. The chassis will be the manufacturer's first line tilt cab.
0021008 Overall Height, Target TARGET OVERALL HEIGHT
The target overall height of the apparatus will be 117.00-118.00". 0000110 Wheelbase WHEELBASE
The wheelbase of the vehicle will be 184.50.
0000070 GVW Rating GVW RATING
The gross vehicle weight rating will be 46,800.
0729280 Frame Rails, 13.38 x 3.50 x .375,
Enforcer
FRAME
The chassis frame will be built with two (2) steel channels bolted to five (5) cross members or more, depending on other options of the apparatus. The side rails will have a 13.38" tall web over the front and mid sections of the chassis, with a continuous smooth taper to 10.75" over the rear axle. Each rail will have a section modulus of 25.992 cubic inches and a resisting bending moment (rbm) of 3,119,040 in-lb over the critical regions of the frame assembly, with a section modulus of 18.96 cubic inches with an rbm of 2,275,200 in-lb over the rear axle. The frame rails will be constructed of 120,000 psi yield strength heat-treated 0.38" thick steel with 3.50" wide flanges.
0889469 Frame Liner, "C/Inv L" 12.50" x 3.00"
x .25", AXT/Vel/Imp/Enf, 56" QVal

FRAME REINFORCEMENT
In addition, a mainframe internal liner will be provided. The liner will be an internal "C" design that steps to an internal "L" design over the rear axle. It will be heat-treated steel measuring 12.50" x

3.00" x 0.25" through the front portion of the liner, stepping to 9.38" x 3.00" x 0.25" through the rear portion of the liner. Each liner will have a section modulus of 13.58 cubic inches, yield strength of 110,000 psi, and rbm of 1,494,042 in-lb. Total rbm at wheelbase center will be 4,391,869 in-lb.

The frame liner will be mounted inside of the chassis frame rail and extend the full length of the frame.
0629940 Axle, Front, Oshkosh TAK-4, Non
Drive, 22,800 lb, Enforcer

FRONT NON DRIVE AXLE
The Oshkosh TAK-4® front axle will be of the independent suspension design with a ground rating of 22,800 lb.

Upper and lower control arms will be used on each side of the axle. Upper control arm castings will be made of 100,000-psi yield strength 8630 steel and the lower control arm casting will be made of 55,000-psi yield ductile iron.

The center cross members and side plates will be constructed out of 80,000-psi yield strength steel.

Each control arm will be mounted to the center section using elastomer bushings. These rubber bushings will rotate on low friction plain bearings and be lubricated for life. Each bushing will also have a flange end to absorb longitudinal impact loads, reducing noise and vibrations.

There will be nine (9) grease fittings supplied, one (1) on each control arm pivot and one (1) on the steering gear extension.

The upper control arm will be shorter than the lower arm so that wheel end geometry provides positive camber when deflected below rated load and negative camber above rated load.

Camber at load will be zero degrees for optimum tire life.

The ball joint bearing will be of low friction design and be maintenance free.

Toe links that are adjustable for alignment of the wheel to the center of the chassis will be provided.

The wheel ends will have little to no bump steer when the chassis encounters a hole or obstacle.

The steering linkage will provide proper steering angles for the inside and outside wheel, based on the vehicle wheelbase.

The axle will have a turning angle of up to 45 degrees.

Bid #: 955 5

11.25 0010427 Suspension, Front TAK-4, 22,800 lb,
Qtm/AXT/Imp/Vel/Enf/SFR

FRONT SUSPENSION
Front Oshkosh TAK-4™ independent suspension will be provided with a minimum ground rating of 22,800 lb.

The independent suspension system will be designed to provide maximum ride comfort. The design will allow the vehicle to travel at highway speeds over improved road surfaces and at moderate speeds over rough terrain with minimal transfer of road shock and vibration to the vehicle's crew compartment.

Each wheel will have torsion bar type spring. In addition, each front wheel end will also have energy absorbing jounce bumpers to prevent bottoming of the suspension.

The suspension design will be such that there is at least 10.00" of total wheel travel and a minimum of 3.75" before suspension bottoms.

The torsion bar anchor lock system allows for simple lean adjustments, without the use of shims.

One can adjust for a lean within 15 minutes per side. Anchor adjustment design is such that it allows for ride height adjustment on each side.

The independent suspension was put through a durability test that simulated 140,000 miles of inner city driving.
0087572 Shock Absorbers, KONI, TAK-4,
Qtm/AXT/Imp/Vel/DCF/Enf

FRONT SHOCK ABSORBERS
KONI heavy-duty telescoping shock absorbers will be provided on the front suspension. 0000322 Oil Seals, Front Axle FRONT OIL SEALS
Oil seals with viewing window will be provided on the front axle. 0899438 Tires, Front, Goodyear, Armor MAX
MSA, 425/65R22.50, 20 ply

FRONT TIRES
Front tires will be Goodyear 425/65R22.50 radials, 20 ply Armor Max MSA, rated for 22,800 lb maximum axle load and 68 mph maximum speed.
0604672 Wheels, Front, Accuride, 22.50" x

12.25", Steel, Hub Pilot
The tires will be mounted on Accuride® 22.50" x 12.25" steel disc type wheels with a ten (10) stud, 11.25" bolt circle.
0530457 Axle, Rear, Meritor RS23-186, 24,000
lb Saber/Enforcer

REAR AXLE
The rear axle will be a Meritor™, Model RS-23-186, with a capacity of 24,000 lb. 0544253 Top Speed of Vehicle, 68 MPH /109
KPH

TOP SPEED OF VEHICLE
A rear axle ratio will be furnished to allow the vehicle to reach a top speed of 68 mph / 109 kph. 0565379 Suspen, Rear, Single Slipper Spring,
24,000 lb, Saber/Enforcer

REAR SUSPENSION
The rear suspension will be Standens, semi-elliptical, 3.00" wide x 52.50" long, with a ground rating of 24,000 lb. The spring hangers will be castings.

The two (2) top leaves will wrap the forward spring hanger pin, and the rear of the spring will be a slipper style end that will ride in a rear slipper hanger.

A steel encased rubber bushing will be used in the spring eye. The steel encased rubber bushing will be maintenance free and require no lubrication.
0000485 Oil Seals, Rear Axle

REAR OIL SEALS
Oil seals will be provided on the rear axle(s).
0782552 Tires, Rear, Goodyear, Endurance
RSA, 12R22.50, LRH, Single

REAR TIRES
Rear tires will be four (4) Goodyear 12R22.50 radials, load range H, Endurance RSA highway tread, rated for 27,120 lb maximum axle load and 75 mph maximum speed. 0654806 Wheels, Rear, Accuride, 22.50" x

8.25", Steel, Hub Pilot, Single

The tires will be mounted on Accuride® 22.50" x 8.25" steel disc type wheels with a ten (10) stud,

11.25" bolt circle.
0568081 Tire Balancing, Counteract Beads

TIRE BALANCE
All tires will be balanced with Counteract balancing beads. The beads will be inserted into the tire and eliminate the need for wheel weights.
0819008 No Tire Pressure Indicator, Fire
Department Omits, Non-NFPA 2024
Compliant

TIRE PRESSURE INDICATOR
NFPA 1900, 2024 edition, section 7.14.6 requires each tire be equipped with a visual indicator or monitoring system that indicates tire pressure.

Per Fire Department specification, a tire pressure indicator is not on the apparatus as manufactured. This apparatus will be non-compliant to NFPA 1900 standards effective at time of contract execution.

Bid #: 955 6

11.26 0801909 Lug Nut, Covers, Chrome

CHROME LUG NUT COVERS
Chrome lug nut covers will be supplied on front and rear wheels. 0003245 Axle Hub Covers w/center hole, S/S,
Front Axle

FRONT HUB COVERS
Stainless steel hub covers will be provided on the front axle. An oil level viewing window will be provided.
0001960 Axle Hub Covers, Rear, S/S, High
Hat (Pair)

REAR HUB COVERS
A pair of stainless steel high hat hub covers will be provided on rear axle hubs. 0002045 Mud Flap, Front and Rear, Pierce
Logo

MUD FLAPS
Mud flaps with a Pierce logo will be installed behind the front and rear wheels. 0544802 Chocks, Wheel, SAC-44-E, Folding,
(Up to 44" Diameter Tires)

WHEEL CHOCKS
There will be one (1) pair of folding Ziamatic, Model SAC-44-E, aluminum alloy, Quick-Choc wheel blocks, with easy-grip handle provided.
0544806 Mounting Brackets, Chocks, SAC-44-
E, Folding, Horizontal
Wheel Chock Brackets
There will be one (1) pair of Zico, Model SQCH-44-H, horizontal mounting wheel chock brackets provided for the Ziamatic, Model SAC-44-E, folding wheel chocks. The brackets will be made of aluminum and consist of a quick release spring loaded rod to hold the wheel chocks in place. The brackets will be mounted below the left side rear compartment and forward of the left side rear tire.
0820509 ESC/ABS/ATC Wabco Brake
System, Single Rear Axle, NFPA
1900

ELECTRONIC STABILITY CONTROL
A vehicle control system will be provided as an integral part of the ABS brake system from Meritor Wabco.

The system will monitor and update the lateral acceleration of the vehicle and compare it to a critical threshold where a side roll event may occur. If the critical threshold is met, the vehicle control system will automatically reduce engine RPM, engage the engine retarder (if equipped), and selectively apply brakes to the individual wheel ends of the front and rear axles to reduce the possibility of a side roll event.

The system will monitor directional stability through a lateral accelerometer, steer angle sensor and yaw rate sensor. If spinout or drift out is detected, the vehicle control system will selectively apply brakes to the individual wheel ends of the front and rear axles to bring the vehicle back to its intended direction.

ANTI-LOCK BRAKE SYSTEM
The vehicle will be equipped with a Wabco 4S4M, anti-lock braking system. The ABS will provide a four (4) channel anti-lock braking control on both the front and rear wheels. A digitally controlled system that utilizes microprocessor technology will control the anti-lock braking system. Each wheel will be monitored by the system. When any wheel begins to lockup, a signal will be sent to the control unit. This control unit will then reduce the braking of that wheel for a fraction of a second and then reapply the brake. This anti-lock brake system will eliminate the lockup of any wheel thus helping to prevent the apparatus from skidding out of control.

AUTOMATIC TRACTION CONTROL
An anti-slip feature will be included with the ABS. The Automatic Traction Control will be used for traction in poor road and weather conditions. The Automatic Traction Control will act as an electronic differential lock that will not allow a driving wheel to spin, thereby supplying traction at all times. The ABS electronic control unit (ECU) will work with the engine ECU, sharing information concerning wheel slip. Engine ECU will use information to control engine speed, allowing only as much throttle application as required for the available traction, regardless of how much the driver is asking for. An "off road traction" switch will be provided on the instrument panel. Activation of the switch will allow additional tire slip to let the truck climb out and get on top of deep snow or mud.
0030185 Brakes, Knorr/Bendix 17", Disc,
Front, TAK-4
BRAKES
The service brake system will be full air type.

The front brakes will be Knorr/Bendix disc type with a 17.00" ventilated rotor for improved stopping distance.

The brake system will be certified, third party inspected, for improved stopping distance. 0509206 Brakes, Meritor, EX225, Disc Plus,
Rear, Single Axle
The rear brakes will be Meritor™, Disc Plus, Model EX225, disc operated with automatic slack adjusters and a 17.00" ventilated rotor for improved stopping distance. 0020784 Air Compressor, Brake,
Cummins/Wabco 18.7 CFM

BRAKE SYSTEM AIR COMPRESSOR
The air compressor will be a Cummins/WABCO with 18.7 cubic feet per minute output.

Bid #: 955 7

11.27 0644232 Brake Reservoirs, 4,272 Cubic Inch
Minimum Capacity, Saber
FR/Enforcer

BRAKE SYSTEM
The brake system will include:

Brake treadle valve
Heated automatic moisture ejector on air dryer
Total air system minimum capacity of 4,272 cubic inches Two (2) air pressure gauges with a red warning light and an audible alarm, that activates when air pressure falls below 60 psi
Spring set parking brake system
Parking brake operated by a push-pull style control valve A parking "brake on" indicator light on instrument panel Park brake relay/inversion and anti-compounding valve, in conjunction with a double check valve system, with an automatic spring brake application at 40 psi A pressure protection valve to prevent all air operated accessories from drawing air from the air system when the system pressure drops below 80 psi (550 kPa) 1/4 turn drain valves on each air tank
The air tank will be primed and painted to meet a minimum 750 hour salt spray test.

The air tanks will be painted black #98.

To reduce the effects of corrosion, the air tank will be mounted with stainless steel brackets. 0568012 Air Dryer, Wabco System Saver
1200, Heater, 2010

BRAKE SYSTEM AIR DRYER
The air dryer will be WABCO System Saver 1200 with spin-on coalescing filter cartridge and 100 watt heater.
0000790 Brake Lines, Nylon BRAKE LINES
Color-coded nylon brake lines will be provided. The lines will be wrapped in a heat protective loom in the chassis areas that are subject to excessive heat. 0617799 Inlet/Outlet, Air, w/Disconnect Fitting,
1/4 Turn Valve, Location

AIR INLET/OUTLET
One (1) air inlet/outlet will be installed with the female coupling located DS PUMP PANEL. This system will tie into the "wet" tank of the brake system and include a check valve in the inlet line and an 85 psi pressure protection valve in the outlet line. The air outlet will be controlled by a 1/4 turn valve.

A mating male fitting will be provided with the loose equipment.

The air inlet will allow a shoreline air hose to be connected to the vehicle. This will allow station air to be supplied to the brake system of the vehicle to insure constant air pressure. 0808497 Engine, Cummins X15, 565 hp, 1850
lb-ft, W/OBD, EPA 2027, Enforcer
ENGINE
The chassis will be powered by an electronically controlled engine as described below:

Make:

Cummins®
Model:

X15
Power:
565 hp at 1700 rpm
Torque:
1850 lb-ft at 1150 rpm
Governed Speed:
2100 rpm
Emissions Level:

EPA 2027
Fuel:

Diesel
Cylinders:

Six (6)
Displacement:
912 cubic inches (14.9L)
Starter:

Delco 39MT+™
Fuel Filters:

Frame mounted spin-on style filter from Cummins®.

The engine will include On-board diagnostics (OBD), which provides self diagnostic and reporting. The system will give the owner or repair technician access to state of health information for various vehicle sub systems. The system will monitor vehicle systems, engine and after treatment. The system will illuminate a malfunction indicator light on the dash console if a problem is detected.

The engine will be filled with FA-4 10W30 oil as required by Cummins. 0811409 Not Required, Engine Contingency
Adjustment
0730808 Filters, Remote Mounted, Oil, Fuel,
X15, VEL/AXT/Enf

REMOTE MOUNTED ENGINE FILTERS
The engine fuel and oil filters will be remote mounted for ease of maintenance.

Bid #: 955 8

11.28 0001244 High Idle w/Electronic Engine,
Custom

HIGH IDLE
A high idle switch will be provided, inside the cab, on the instrument panel, that will automatically maintain a preset engine rpm. A switch will be installed, at the cab instrument panel, for activation/deactivation.

The high idle will be operational only when the parking brake is on and the truck transmission is in neutral. A green indicator light will be provided, adjacent to the switch. The light will illuminate when the above conditions are met. The light will be labeled "OK to Engage High Idle." 0687994 Engine Brake, Jacobs Compression
Brake, Cummins Engine

ENGINE BRAKE
A Jacobs® engine brake is to be installed with the controls located on the instrument panel within easy reach of the driver.

The driver will be able to turn the engine brake system on/off and have a high, medium and low setting.

The engine brake will activate when the system is on and the throttle is released.

The high setting of the brake application will activate and work simultaneously with the variable geometry turbo (VGT) provided on the engine.

The engine brake will be installed in such a manner that when the engine brake is slowing the vehicle the brake lights are activated.

The ABS system will automatically disengage the auxiliary braking device, when required. 0552334 Clutch, Fan, Air Actuated, Horton
Drive Master

CLUTCH FAN
A Horton® fan clutch will be provided. The fan clutch will be automatic when the pump transmission is in "Road" position, and fully engaged in "Pump" position. 0657451 Heater, 1500 Watt Immersion,
Thermostatically Controlled,
Shoreline

ENGINE HEATER
A 1,500 watt, 120 volt, immersion type engine heater will be installed. The AC power inlet will be connected to the shoreline. The heater is thermostatically controlled. 0644573 Air Intake, Water & Ember Screen,
Saber FR/Enforcer

ENGINE AIR INTAKE
The engine air intake will be located above the engine cooling package. It will draw fresh air from the front of the apparatus through the radiator grille.

The ember separator is designed to prevent road dirt and recirculating hot air from entering the engine.

The ember separator will be easily accessible by tilting the cab. 0814375 Exhaust System, Horizontal, Right
Side

EXHAUST SYSTEM
The exhaust system will be stainless steel from the turbo to the engine's aftertreatment device.

The exhaust system will include an aftertreatment device to meet current EPA standards. An insulation wrap will be provided on all exhaust pipe between the turbo and the aftertreatment device to minimize the transfer of heat to the cab.

The exhaust will terminate horizontally ahead of the right side rear wheels and will be flush with the body rub rail. The exhaust pipes will be aluminized steel.

There will be an aluminized steel exhaust diffuser reduced to 5.00" in the center to accommodate the fire department's air recovery system with a standard straight tip on the end provided to reduce the temperature of the exhaust as it exits. Heat deflector shields will be provided to isolate chassis and body components from the heat of the tailpipe diffuser. 0788765 Radiator, Saber FR/Enforcer

RADIATOR
The radiator and the complete cooling system will meet or exceed the current edition of applicable NFPA and engine manufacturer cooling system standards.

For maximum corrosion resistance and cooling performance, the entire radiator core will be constructed using long life aluminum alloy. The radiator core will consist of aluminum fins, having a serpentine design, brazed to aluminum tubes.

The radiator core will have a minimum front area of 1060 square inches.

Supply tank will be made of heavy duty glass-reinforced nylon and the return tank will be made of aluminum. Both tanks will be crimped onto the core assembly using header tabs and a compression gasket to complete the radiator core assembly. There will be a full steel frame around the inserts to enhance cooling system durability and reliability.

The radiator will be compatible with commercial antifreeze solutions.

The radiator assembly will be isolated from the chassis frame rails with rubber isolators to prevent the development of leaks caused by twisting or straining when the apparatus operates over uneven terrain.

The radiator will include a de-aeration/expansion tank. For visual coolant level inspection, the radiator will have a built-in sight glass. The radiator will be equipped with a 15 psi pressure relief cap.

A drain port will be located at the lowest point of the cooling system and/or the bottom of the radiator to permit complete flushing of the coolant from the system.

Shields or baffles will be provided to prevent recirculation of hot air to the inlet side of the radiator. 0001090 Cooling Hoses, Rubber

COOLANT LINES
Gates, or Goodyear, rubber hose will be used for all engine coolant lines installed by Pierce Manufacturing.

Hose clamps will be stainless steel constant torque type to prevent coolant leakage. They will expand and contract according to coolant system temperature thereby keeping a constant clamping pressure on the hose.

Bid #: 955 9

11.29 0001125 Fuel Tank, 65 Gallon, Left Side Fill

FUEL TANK
A 65 gallon fuel tank will be provided and mounted at the rear of the chassis. The tank will be constructed of 12-gauge, hot rolled steel. It will be equipped with swash partitions and a vent. To eliminate the effects of corrosion, the fuel tank will be mounted with stainless steel straps.

A 0.75" drain plug will be located in a low point of the tank for drainage.

A fill inlet will be located on the left hand side of the body and is covered with a hinged, spring loaded, stainless steel door that is marked "Ultra Low Sulfur - Diesel Fuel Only." A 0.50" diameter vent will be installed from tank top to just below fuel fill inlet.

The fuel tank will meet all FHWA 393.67 requirements including a fill capacity of 95 percent of tank volume.
0001129 Lines, Fuel All fuel lines will be provided as recommended by the engine manufacturer. 0662965 DEF Tank, 4.5 Gallon, DS Fill, Rear
of Axle, Common Air Bottle Door

DIESEL EXHAUST FLUID TANK
A 4.5 gallon diesel exhaust fluid (DEF) tank will be provided and mounted in the driver's side body rearward of the rear axle.

A 0.50" drain plug will be provided in a low point of the tank for drainage.

A fill inlet will be provided and marked "Diesel Exhaust Fluid Only". The fill inlet will be located adjacent to the air bottle storage behind a common door on the driver side of the vehicle.

The tank will meet the engine manufacturers requirement for 10 percent expansion space in the event of tank freezing.

The tank will include an integrated heater unit that utilizes engine coolant to thaw the DEF in the event of freezing.
0723716 Fuel Priming Pump, Electronic,
Automatic, Cummins, No Swt Req'd

FUEL PRIMING PUMP
A Cummins automatic electronic fuel priming pump will be integrated as part of the engine. 0552712 Not Required, Shutoff Valve, Fuel
Line
0699437 Cooler, Chassis Fuel, Not Req'd.

0578959 Fuel/Water Separator, Racor Inline

FUEL SEPARATOR
The engine will be equipped with a Racor in-line spin-on fuel and water separator in addition to the engine fuel filters.
0887546 Trans, Allison 6th Gen, 4000 EVS P,
w/Prognostics, Imp/Vel/SFR/Enf

TRANSMISSION
An Allison 6th generation, Model EVS 4000P, electronic, torque converting, automatic transmission will be provided.

The transmission will be equipped with prognostics to monitor oil life, filter life, and transmission health. A wrench icon on the shift selector's digital display will indicate when service is due.

Two (2) PTO openings will be located on left side and top of converter housing (positions 8 o'clock and 1 o'clock).

A transmission temperature gauge with an amber light and buzzer will be installed on the cab instrument panel.
0625331 Transmission, Shifter, 6-Spd, Push
Button, 4000 EVS

TRANSMISSION SHIFTER
A six (6)-speed push button shift module will be mounted to right of driver on console. Shift position indicator will be indirectly lit for after dark operation.

The transmission ratio will be:
1st

3.51 to 1.00
2nd

1.91 to 1.00
3rd

1.43 to 1.00
4th

1.00 to 1.00
5th

0.75 to 1.00
6th

0.64 to 1.00
R

4.80 to 1.00
0684459 Transmission Oil Cooler, Modine,
External

TRANSMISSION COOLER
A Modine plate and fin transmission oil cooler will be provided using engine coolant to control the transmission oil temperature.

Bid #: 955 10 11.30
0522824 Mode, Downshift, Aggressive
downshift to 3rd, w/engine brake, 6
speed
DOWNSHIFT MODE (w/engine brake)
The transmission will be provided with an aggressive downshift mode.

This will provide earlier transmission downshifts to 3rd gear from 6th gear, resulting in improved engine braking performance.
0801876 Fluid, 4000 Series Trans, Allison
Approved TES-668 Synthetic, IPOS,
Custom

TRANSMISSION FLUID
The transmission will be provided with TranSynd, or other Allison approved TES-668 heavy duty synthetic transmission fluid.
0001375 Driveline, Spicer 1810 DRIVELINE
Drivelines will be a heavy-duty metal tube and be equipped with Spicer® 1810 universal joints.

The shafts will be dynamically balanced before installation.

A splined slip joint will be provided in each driveshaft where the driveline design requires it. The slip joint will be coated with Glidecoat® or equivalent. 0669988 Steering, Sheppard M110 w/Tilt, TAK4, Eaton Pump, w/Cooler STEERING Dual Sheppard, Model M110, steering gears, with integral heavy-duty power steering, will be provided. For reduced system temperatures, the power steering will incorporate an air to oil cooler and an Eaton, Model VN20, hydraulic pump with integral pressure and flow control. All power steering lines will have wire braded lines with crimped fittings.

A tilt and telescopic steering column will be provided to improve fit for a broader range of driver configurations.
0605356 Steering Wheel, 4 Spoke without
Controls, Saber FR/Enforcer

STEERING WHEEL
The steering wheel will be 18.00" in diameter, have tilting and telescoping capabilities, and a 4- spoke design.
0550144 Logo/Emblem, on Horn Button

LOGO AND CUSTOMER DESIGNATION ON HORN BUTTON
The steering wheel will have an emblem containing the Pierce logo and customer name. The emblem will have three (3) rows of text for the customer's department name. There will be a maximum of eight (8) characters in the first row, 11 characters in the second row and 11 characters in the third row.

The first row of text will be: BLANK
The second row of text will be: SANTA CRUZ
The third row of text will be: FIRE DEPT
0630342 Bumper, 16" Extended, Steel Painted,
Saber FR/Enforcer
BUMPER
A one (1) piece bumper manufactured from 0.25" formed steel with a 0.38" bend radius will be provided. The bumper will be a minimum of 10.00" high with a 1.50" top and bottom flange, and will extend 16.00" from the face of the cab. The bumper will be 95.28" wide with 45 degree corners and side plates. The bumper will be metal finished and painted job color.

To provide adequate support strength, the bumper will be mounted directly to the front of the C channel frame. The frame will be a bolted modular extension frame constructed of 50,000 psi tensile steel.

Gravel Pan
A gravel pan, constructed of bright aluminum treadplate, will be furnished between the bumper and the cab face. The pan will be properly supported from the underside to prevent flexing and vibration.
0725516 No Selection Required, No Bumper
Tray Selected
0637794 Tray, (1) Hose Left Side of Bumper,
Special Capacity

LEFT SIDE HOSE TRAY
A hose tray will be placed in the left side of the extended bumper.

The tray will have a capacity of 200' of 1.00" forestry hose Black rubber grating will be provided at the bottom of the tray. Drain holes will be provided. 0633467 Hose Restraint, Bumper Tray, Velcro
Straps, Pair
Left Side Hose Tray Restraint
There will be one (1) pair hose tray restraint straps located over the left side mounted tray.

The restraints will be a pair of 2.00" wide black nylon straps with Velcro® fasteners provided. The strap(s) will be used to secure the hose in the tray.
0663647 Tray, (1) Hose Right Side of Bumper

RIGHT SIDE HOSE TRAY
A hose tray will be placed in the right side of the extended bumper.

The tray will have a capacity of 70' of 1.75" double jacket cotton-polyester hose.

Black rubber grating will be provided at the bottom of the tray. Drain holes will be provided.

Bid #: 955 11 11.31
0633453 Hose Restraint, Bumper Tray, Velcro
Straps, Pair
Right Side Hose Tray Restraint
There will be one (1) pair hose tray restraint straps over the right side hose tray.

The restraints will be a pair of 2.00" wide black nylon straps with Velcro® fasteners provided. The strap(s) will be used to secure the hose in the tray.
0778092 Lift & Tow Package, Enforcer

LIFT AND TOW MOUNTS
Mounted to the frame extension will be lift and tow mounts. The lift and tow mounts will be designed and positioned to adapt to certain tow truck lift systems.

The lift and tow mounts with eyes will be painted the same color as the frame. 0049964 Tow Eyes, Painted Black, Extended
Out Front of Bumper

TOW EYES
Two (2) tow eyes will be mounted through the front face of the bumper.

The inner and outer edges of the tow eyes will have a .25" radius.

The tow eyes will be mounted directly to the bumper frame.

Cutouts will be provided in the front face of the stainless steel bumper to allow the tow eyes to extend out the front.

The tow eyes will be designed and positioned to allow up to a 9,000 lb straight horizontal pull in line with the centerline of the vehicle. The tow eyes will not be used for lifting of the apparatus.

The tow eyes will be painted black.
0543824 Angle Tray Flooring, 45 deg, Increase
Angle of Approach, Reduce Capacity

SPECIAL TRAY FLOORING
The bottom of the front bumper trays will be angled at 45 degrees to ensure that they will not decrease the trucks angle of approach.
0516238 Partition, Adjustable, Aluminum in
Hose Tray, Qty, Location

ADJUSTABLE HOSE TRAY PARTITION
There will be one (1) adjustable aluminum partition(s) provided in the bumper hose tray located driver side tray, mounted side to side, with the divider positioned 3.00" from the rear wall of the tray, match 26143.
0698960 Coating, Top Flange, Front Bumper,
Outside Exterior, UL-LX Coating,
Black

FRONT BUMPER UL-LX COATING
Protective black UL-LX® coating will be provided on the outside exterior of the top front bumper flange. It will not be sprayed on the underside of the flange.

The lining will be properly installed by an authorized UL-LX dealer.

Bid #: 955 12 11.32
0625650 Cab, Enforcer, 7000

CAB
The Enforcer cab will be designed specifically for the fire service and manufactured by the chassis builder.

The cab will be built by the apparatus manufacturer in a facility located on the manufacturer's premises.

For reasons of structural integrity and enhanced occupant protection, the cab will be a heavy duty design, constructed to the following minimal standards.

The cab will have 12 main vertical structural members located in the A-pillar (front cab corner posts), B-pillar (side center posts), C-pillar (rear corner posts), and rear wall areas. The A-pillar will be constructed of solid A356-T5 aluminum castings. The B-pillar and C-pillar will be constructed from 0.13" wall extrusions. The rear wall will be constructed of two (2) 2.00" x 2.00" outer aluminum extrusions and two (2) 2.00" x 1.00" inner aluminum extrusions. All main vertical structural members will run from the floor to 4.625" x 3.864" x 0.090" thick roof extrusions to provide a cage-like structure with the A-pillar and roof extrusions being welded into a 0.25" thick corner casting at each of the front corners of the roof assembly.

The front of the cab will be constructed of a 0.13" firewall plate, covered with a 0.090" front skin (for a total thickness of 0.22"), and reinforced with a full width x 0.50" thick cross-cab support located just below the windshield and fully welded to the engine tunnel. The cross-cab support will run the full width of the cab and weld to each A-pillar, the 0.13" firewall plate, and the front skin.

The cab floors will be constructed of 0.125" thick aluminum plate and reinforced at the firewall with an additional 0.25" thick cross-floor support providing a total thickness of 0.375" of structural material at the front floor area. The front floor area will also be supported with two (2) triangular

0.30" wall extrusions that also provides the mounting point for the cab lift. This tubing will run from the floor wireway of the cab to the engine tunnel side plates, creating the structure to support the forces created when lifting the cab.

The cab will be 96.00" wide (outside door skin to outside door skin) to maintain maximum maneuverability.

The centerline of front axle to the rear of the cab will be 70.00" long.

The overall height (from the cab roof to the ground) of approximately 99.00". The overall height listed will be calculated based on a truck configuration with the lowest suspension weight rating, the smallest diameter tires for the suspension, no water weight, no loose equipment weight, and no personnel weight. Larger tires, wheels, and suspension will increase the overall height listed.

The floor to ceiling height inside the crew cab will be 54.50" in the center and outboard positions.

The crew cab floor will measure 46.00" from the rear wall to the back side of the rear facing seat risers.

The medium block engine tunnel, at the rearward highest point (knee level), will measure 61.50" to the rear wall. The big block engine tunnel will measure 51.50" to the rear wall.

The crew cab will be a totally enclosed design with the interior area completely open to improve visibility and verbal communication between the occupants.

The cab will be a full tilt cab style.

A 3-point cab mount system with rubber isolators will improve ride quality by isolating chassis vibrations from the cab.

CAB ROOF DRIP RAIL
For enhanced protection from inclement weather, a drip rail will be furnished on the sides of the cab. The drip rail will be painted to match the cab roof, and bonded to the sides of the cab. The drip rail will extend the full length of the cab roof.

FENDER LINERS
Full circular inner fender liners in the wheel wells will be provided.

PANORAMIC WINDSHIELD
A one (1)-piece safety glass windshield will be provided with over 2,775 square inches of clear viewing area. The windshield will be full width and will provide the occupants with a panoramic view. The windshield will consist of three (3) layers: outer light, middle safety laminate, and inner light. The outer light layer will provide superior chip resistance. The middle safety laminate layer will prevent the windshield glass pieces from detaching in the event of breakage. The inner light will provide yet another chip resistant layer. The cab windshield will be bonded to the aluminum windshield frame using a urethane adhesive. A custom frit pattern will be applied on the outside perimeter of the windshield for a finished automotive appearance.

WINDSHIELD WIPERS
Three (3) electric windshield wipers with washer will be provided that meet FMVSS and SAE requirements.

The washer reservoir will be able to be filled without raising the cab. 0727969 Engine Tunnel, X15, Foil Insulation
w/Mech Fasteners, Enforcer

ENGINE TUNNEL
Engine tunnel side walls will be constructed of 0.375" aluminum. The top will be constructed of

0.125" aluminum and will be tapered at the top to allow for more driver and passenger elbow room.

The engine tunnel will be insulated for protection from heat and sound. Perforated foil faced insulation will be over a 1.00" thick closed cell foam affixed with pressure sensitive adhesive and further secured with mechanical fasteners. Thermal rating for this insulation will be -40 degrees Fahrenheit to 300 degrees Fahrenheit. The noise insulation keeps the dBA level within the limits stated in the current edition of applicable NFPA standards.

The engine tunnel will be no higher than 18.00" off the crew cab floor. 0887601 Cab Insulation, Enforcer/Saber FR INTERIOR CAB INSULATION The cab will include 1.00" insulation in the ceiling, 1.50" insulation in the side walls, a minimum of

1.00" insulation in the crew cab floor, and 2.00" insulation in the rear wall to maximize acoustic absorption and thermal insulation.

Bid #: 955 13 11.33
0633594 Rear Wall, Interior, Adjustable
Seating

INTERIOR CREW CAB REAR WALL ADJUSTABLE SEATING (PATENT PENDING) The interior rear wall of the crew cab will have mounting holes every 2.75" to allow for adjustability of the forward facing crew cab seating along the rear wall. Seats will be adjustable with use of simple hand tools allowing departments flexibility of their seating arrangement should their department needs change.
0632103 Rear Wall, Exterior, Cab, Saber
FR/Enforcer

CAB REAR WALL EXTERIOR COVERING
The exterior surface of the rear wall of the cab will be overlaid with bright aluminum treadplate except for areas that are not typically visible when the cab is lowered. 0639727 Cab Lift, Elec/Hyd, Manual Override,
Saber FR/Enforcer

CAB LIFT
A hydraulic cab lift system will be provided consisting of an electric powered hydraulic pump, dual lift cylinders, and necessary hoses and valves.

Hydraulic pump will have a manual override for backup in the event of electrical failure.

Lift controls will be located on the right side pump panel or front area of the body in a convenient location.

The cab will be capable of tilting 43 degrees to accommodate engine maintenance and removal.

The cab will be locked down by a 2-point normally closed spring loaded hook type latch that fully engages after the cab has been lowered. The system will be hydraulically actuated to release the normally closed locks when the cab lift control is in the raised position and cab lift system is under pressure. When the cab is completely lowered and system pressure has been relieved, the spring loaded latch mechanisms will return to the normally closed and locked position.

The hydraulic cylinders will be equipped with a velocity fuse that protects the cab from accidentally descending when the control is located in the tilt position.

For increased safety, a redundant mechanical stay arm will be provided that must be manually put in place on the left side between the chassis and cab frame when the cab is in the raised position. This device will be manually stowed to its original position before the cab can be lowered.

Cab Lift Interlock
The cab lift system will be interlocked to the parking brake. The cab tilt mechanism will be active only when the parking brake is set and the ignition switch is in the on position. If the parking brake is released, the cab tilt mechanism will be disabled. 0695930 Grille, Bright Finished, Front of Cab,
Enforcer
GRILLE
A bright finished aluminum mesh grille screen, inserted behind a bright finished grille surround, will be provided on the front center of the cab.
0647932 Not Required, Trim, S/S Band, Across
Cab Face, AXT/Saber/Enforcer

0087357 Molding, Chrome on Side of Cab

SIDE OF CAB MOLDING
Chrome molding will be provided on both sides of cab.
0521669 Mirrors, Retrac, West Coast Style,
Htd/Rmt, w/Htd/Rmt Convex

MIRRORS
A Retrac, Model 613423, dual vision, motorized, west coast style mirror, with chrome finish, will be mounted on each side of the front cab door with spring loaded retractable arms. The flat glass and convex glass will be heated and adjustable with remote control within reach of the driver. 0648171 Door, Half-Height, Saber FR/Enforcer
4-Door Cab, Level Roof
DOORS
To enhance entry and egress to the cab, the forward cab door openings will be a minimum of

37.50" wide x 63.37" high. The crew cab doors will be located on the sides of the cab and will be constructed in the same manner as the forward cab doors. The crew cab door openings will be a minimum of 34.30" wide x 63.37" high.

The forward cab and crew cab doors will be constructed of extruded aluminum with a nominal material thickness of 0.093". The exterior door skins will be constructed from 0.090" aluminum.

A customized, vertical, pull-down type door handle will be provided on the exterior of each cab door. The finish of the door handle will be chrome/black. The exterior handle will be designed specifically for the fire service to prevent accidental activation, and will provide 4.00" wide x 2.00" deep hand clearance for ease of use with heavy gloved hands.

Each door will also be provided with an interior flush, open style paddle handle that will be readily operable from fore and aft positions, and be designed to prevent accidental activation. The interior handles will provide 4.00" wide x 1.25" deep hand clearance for ease of use with heavy gloved hands.

The cab doors will be provided with both interior (rotary knob) and exterior (keyed) locks exceeding FMVSS standards. The keys will be Model 751. The locks will be capable of activating when the doors are open or closed. The doors will remain locked if locks are activated when the doors are opened, then closed.

A full length, heavy duty, stainless steel, piano-type hinge with a 0.38" pin and 11 gauge leaf will be provided on all cab doors. There will be double automotive-type rubber seals around the perimeter of the door framing and door edges to ensure a weather-tight fit.

A chrome handle will be provided on the inside of each cab door for ease of entry.

A red webbed grab handle will be installed on the crew cab door stop strap. The grab handles will be securely mounted.

The bottom cab step at each cab door location will be located below the cab doors and will be exposed to the exterior of the cab.

Bid #: 955 14 11.34
0655543 Door Panel, Brushed Stainless Steel,
Saber/Enforcer 4-Door Cab
Door Panels
The inner cab door panels will be constructed out of brushed stainless steel. 0630636 Controls, Electric Roll-Up Windows,
4dr, 4 Driver Controls, Saber
FR/Enforcer

ELECTRIC OPERATED CAB DOOR WINDOWS
All four (4) cab doors will be equipped with electric operated windows with one (1) flush mounted automotive style switch on each door. The driver's door will have four (4) switches, one (1) to control each door window.

Each switch will allow intermittent or auto down operation for ease of use. Auto down operation will be actuated by holding the window down switch for approximately 1 second. 0638310 Steps, 4-Door Cab, Saber
FR/Enforcer

CAB STEPS
The forward cab and crew cab access steps will be a full size two (2) step design to provide largest possible stepping surfaces for safe ingress and egress. The bottom steps will be designed with a grip pattern punched into bright aluminum treadplate material to provide support, slip resistance, and drainage. The bottom steps will be a bolt-in design to minimize repair costs should they need to be replaced. The forward cab steps will be a minimum 25.00" wide, and the crew cab steps will be 21.65" wide with a 10.00" minimum depth. The inside cab steps will not exceed 16.50" in height.

The vertical surfaces of the step well will be aluminum treadplate. 0770194 Handrail, Exterior, Knurled, Alum, 4-
Door Cab

CAB EXTERIOR HANDRAILS
A 1.25" diameter slip-resistant, knurled aluminum handrail will be provided adjacent to each cab and crew cab door opening to assist during cab ingress and egress. 0892638 Lights, Cab & Crw Cab Acs Stps,
P25, LED w/Bezel, 6lts

STEP LIGHTS
There will be six (6) white LED step lights with chrome housing installed for cab and crew cab access steps.

One (1) light for the left access steps.

Two (2) lights for the left side crew cab access steps.

Two (2) lights for the right side crew cab access steps.

One (1) light for the right side access step.

In order to ensure exceptional illumination, each light will provide a minimum of 25 foot-candles (fc) covering an entire 15" x 15" square placed ten (10) inches below the light and a minimum of

1.5 fc covering an entire 30" x 30" square at the same ten (10) inch distance below the light.

The lights will be activated when the battery switch is on and the adjacent door is opened. 0583698 Fenders, S/S on cab, Extra Wide,
Saber/Enf

FENDER CROWNS
Stainless steel fender crowns will be installed at the cab wheel openings. 0042105 No Windows, Side of Crew Cab

0734681 Compt, Storage, 13.75 W x 24 H x 15
D, (1) Ea Side C/C, Single Pan, 70"
SFR/Enf

STORAGE COMPARTMENTS
Provided on each side of the cab, to the rear of the crew cab access doors, will be a storage compartment.

The compartments will be 13.75" wide x 24.00" high x 15.00" deep.

The doors will be two (2) reverse hinged single pan doors painted to match the cab exterior with a non-locking D-Ring latch, one (1) on each side of the cab. A pneumatic stay arm for each exterior door will be used as a doorstop.

The compartment interior will be painted to match the cab interior.

Compartment Light
There will be two (2) white LED strip lights provided, one (1) horizontally above each compartment door opening.
0894089 Dash, Heavy Duty Metal, Enforcer

CAB DASH
The driver side dash, switch panel located to the right of the driver, and center console will be constructed of metal and painted to match the cab interior.

The officer side dash will be a flat top design with an upper beveled edge to provide easy maintenance and will be constructed out of aluminum and painted to match the cab interior.

The instrument gauge cluster will be surrounded with a high impact ABS plastic contoured to the same shape of the instrument gauge cluster.

Bid #: 955 15 11.35
0797232 Cab Interior, Imperial 1200, UL-LX,
Basic Level, Enforcer

CAB INTERIOR
The cab interior will be constructed of aluminum to withstand the severe duty cycles of the fire service.

The following items will be sprayed with dark gray polyurethane/polyurea elastomer abrasive resistant material. The abrasive resistant material will be properly sprayed by an authorized ULLX® dealer.

Officer side dash
Glove box in front of officer (if applicable)
Power distribution in front of officer
Engine tunnel
Fluid check access door
Scuffplate on bottom rear of engine tunnel
Evaporator drain tubes
Permanent seat risers
Riser cover behind driver and officer seats
For durability and ease of maintenance, the cab interior side walls will be painted aluminum. The rear wall will be painted aluminum.

Headliner will be installed in both forward and rear cab sections. Headliner material will be Imperial 1200 vinyl coated polyester. A sound barrier will be part of its composition. Material will be installed on aluminum sheet and securely fastened to interior cab ceiling.

Forward portion of cab headliner will permit easy access for service of electrical wiring or other maintenance needs.

All wiring will be placed in metal raceways. Routing through holes in tubing will not be accepted due to chaffing that installation will cause.

CAB INTERIOR UPHOLSTERY
The cab interior upholstery will be gray woven with black. 0753903 Cab Interior, Paint Color, Saber
FR/Enforcer

CAB INTERIOR PAINT
The cab interior metal surfaces, excluding the rear heater panels, will be painted gray, vinyl texture paint.

The rear heater panels will be painted black, vinyl textured paint. 0052100 Floor, Rubber Padded, Cab & Crew
Cab, Saber/Enforcer

CAB FLOOR
The cab and crew cab floor areas will be covered with Polydamp™ acoustical floor mat consisting of a black pyramid rubber facing and closed cell foam decoupler.

The top surface of the material has a series of raised pyramid shapes evenly spaced, which offer a superior grip surface. Additionally, the material has a 0.25" thick closed cell foam (no water absorption) which offers a sound dampening material for reducing sound levels.

Bid #: 955 16 11.36
0722038 HVAC, Heavy-Duty, Enforcer, w/X15,
CARE

DEFROST/AIR CONDITIONING SYSTEM
A ceiling mounted combination heater, defroster and air conditioning system will be installed in the cab above the engine tunnel area.

Cab Defroster
A 54,000 BTU heater-defroster unit with 690 SCFM of air flow will be provided inside the cab. The heater-defrost will be installed in the forward portion of the cab ceiling. Air outlets will be strategically located in the cab header extrusion per the following:

One (1) adjustable outlet directed towards the left side cab window.

One (1) adjustable outlet directed towards the right side cab window.

Six (6) fixed outlets directed at the windshield.

The defroster will be capable of clearing 98 percent of the windshield and side glass when tested under conditions where the cab has been cold soaked at 0 degrees Fahrenheit for 10 hours, and a 2 ounce per square inch layer of frost/ice has been able to build up on the exterior windshield.

The defroster system will meet or exceed SAE J382 requirements.

Cab/Crew Auxiliary Heater
There will be one (1) 31,000 BTU auxiliary heater with 560 SCFM of air flow provided in each outboard rear facing seat risers with a dual scroll blower. An aluminum plenum incorporated into the cab structure used to transfer heat to the forward positions.

Air Conditioning
A 19.10 cubic inch compressor will be installed on the engine.

A roof-mounted condenser with a 78,000 BTU output at 2,400 SCFM that meets and exceeds the performance specification will be installed on the cab roof. The condenser cover to be painted #10 white.

The air conditioning system will be capable of cooling the average cab temperature from 100 degrees Fahrenheit to 75 degrees Fahrenheit at 50 percent relative humidity within 30 minutes.

The cooling performance test will be run only after the cab has been heat soaked at 100 degrees Fahrenheit for a minimum of 4 hours.

The evaporator unit will be installed in the rear portion of the cab ceiling over the engine tunnel.

The evaporator will include one (1) high performance heating core, one (1) high performance cooling core with (1) plenum directed to the front and one (1) plenum directed to the rear of the cab. The rear plenum will be covered with a metal cover painted to match the cab interior.

The evaporator unit will have a 52,000 BTU at 690 SCFM rating that meets and exceeds the performance specifications.

Adjustable air outlets will be strategically located on the forward plenum cover per the following:

Four (4) outlets directed towards the seating position on the left side of the cab.

Four (4) outlets directed towards the seating position on the right side of the cab.

Adjustable air outlets will be strategically located on the evaporator cover per the following:

Minimum of five (5) outlets directed towards crew cab area.

A high efficiency particulate air (HEPA) filter will be included for the system. Access to the filter cover will be secured with four (4) screws.

The air conditioner refrigerant will be R-134A and will be installed by a certified technician.

Climate Control
An automotive style controller will be provided to control the heat and air conditioning system within the cab. The controller will have three (3) functional knobs for fan speed, temperature, and air flow distribution (front to rear) control.

The system will control the temperature of the cab and crew cab automatically by pushing the center of the fan speed control knob. Rotate the center temperature control knob to set the cab and crew cab temperature.

The AC system will be manually activated by pushing the center of the temperature control knob.

Pushing the center of the air flow distribution knob will engage the AC for max defrost, setting the fan speeds to 100 percent and directing all air flow to the overhead forward position.

The system controller will be located within panel position #12.

Gravity Drain Tubes
Two (2) condensate drain tubes will be provided for the air conditioning evaporator. The drip pan will have two (2) drain tubes plumbed separately to allow for the condensate to exit the drip pan.

No pumps will be provided.
0624005 Sun Visor, Vinyl/Fabric, AXT, Qtm,
SFR/Enf

SUN VISORS
There will be two (2) Imperial 1200 covered sun visors provided. The sun visors will be located above the windshield with one (1) mounted on each side of the cab.

There will be a polished stainless steel bracket provided to help secure each sun visor in the stowed position.
0634328 Grab Handles, Driver and Officer
Door Posts, Saber FR/Enforcer

GRAB HANDLES
A black rubber covered grab handle will be mounted on the door post of the driver and officer's side cab door to assist in entering the cab. The grab handles will be securely mounted to the post area between the door and windshield.
0583938 Lights, Engine Compt, Custom, Auto
Sw, Wln 3SC0CDCR, 3" LED, Trim

ENGINE COMPARTMENT LIGHTS
There will be two (2) Whelen, Model 3SC0CDCR, 12 volt DC, 3.00" white LED light(s) with Whelen, Model 3FLANGEC, chrome flange kit(s) installed under the cab to be used as engine compartment illumination.

These light(s) will be activated automatically when the cab is raised.

Bid #: 955 17 11.37
0631830 Fluid Check Access, Saber
FR/Enforcer, Arrow XT

ACCESS TO ENGINE DIPSTICKS
For access to the engine oil and transmission fluid dipsticks, there will be a door on the engine tunnel, inside the crew cab. The door will be on the rear wall of the engine tunnel, on the vertical surface.

The engine oil dipstick will allow for checking only. The transmission dipstick will allow for both checking and filling.

The door will have a rubber seal for thermal and acoustic insulation. One (1) flush lift and turn latch will be provided on the access door.
0002508 Map Box, 3 Bin/30 deg Slant, Custom
Chassis

MAP BOX
There will be one (1) map box(es) with three (3) bins, open at top. The map box(es) will be installed at final inspection. The map box(es) will be divided into three (3) bins, each being 12.50" wide x 3.00" high x 12.00" deep. Each bin will slant 30 degrees from horizontal. The map box(es) will be constructed of 0.125" aluminum and will be painted to match the cab interior. 0583039 Not Required, Side Roll and Frontal
Impact Protection
0622619 Seating Capacity, 4 Seats

SEATING CAPACITY
The seating capacity of the vehicle (including tiller cab and belted seat positions in the rescue body) will be four (4).
0636957 Seat, Driver, Pierce PSV, Air Ride,
High Back, PRIMARY, SFR/Enf

DRIVER SEAT
A seat will be provided in the cab for the driver. The seat design will be a cam action type, with air suspension. For increased convenience, the seat will include a manual control to adjust the horizontal position (6.00" travel). The manual horizontal control will be a towel-bar style located below the forward part of the seat cushion. To provide flexibility for multiple driver configurations, the seat will have an adjustable reclining back. The seat back will be a high back style with side bolster pads for maximum support. For optimal comfort, the seat will be provided with 17.00" deep foam cushions designed with EVC (elastomeric vibration control).

The seat will be furnished with a 3-point, shoulder type seat belt. 0632923 Seat, Officer, Pierce PSV, Air Ride,
High Back, PRIMARY, SFR/Enf

OFFICER SEAT
A seat will be provided in the cab for the passenger. The seat design will be a cam action type, with air suspension. The seat back will be a high back style with 9 degree fixed recline angle and side bolster pads for maximum support. For optimal comfort, the seat will be provided with 17.00" deep foam cushions designed with EVC (elastomeric vibration control).

The seat will be furnished with a 3-point, shoulder type seat belt. 0002517 Not Required, Radio Compartment
0771805 Cabinet, Rear Facing, LS, 23 W x 34
H x 26.75 D, Lap, Ext Acc, SFR/Enf

REAR FACING LEFT SIDE CABINET
A rear facing cabinet will be provided in the crew cab at the left side outboard position.

The cabinet will be 23.00" wide x 34.00" high x 26.75" deep with one (1) lap door hinged on the inboard side, painted to match the cab interior with two (2) non-locking flush lift and turn latches.

The interior clear door opening of the cabinet will be 16.00" wide x 31.50" high.

The cabinet will also provide access from outside the cab with one (1) reverse hinged double pan door painted to match the cab exterior with a locking D-ring latch with #1250 key. A pneumatic stay arm will be provided as a door stop. The door will be located on the side of the cab over the wheelwell. The clear door opening will be 17.00" wide x 29.25" high.

The cabinet will include no adjustable shelves or traysin the cabinet interior.

The cabinet will include no louvers.

The exterior access will be provided with a brushed stainless steel scuffplate on the lower door frame.

The cabinet will be constructed of smooth aluminum and painted to match the cab interior.

Cabinet Light
There will be one (1) white LED strip light installed on the right side of the interior cabinet door opening. The lighting will be controlled by an automatic door switch. 0102783 Not Required, Seat, Rr Facing C/C,
Center
Bid #: 955 18 11.38
0767426 Cabinet, Rear Facing, RS, 22 W x 34
H x 26.75 D, Lap, Ext Acc, SFR/Enf

REAR FACING RIGHT SIDE CABINET
A rear facing cabinet will be provided in the crew cab at the right side outboard position.

The cabinet will be 22.00" wide x 34.00" high x 26.75" deep with one (1) lap door hinged on the inboard side, painted to match the cab interior with two (2) non-locking flush lift and turn latches.

The clear door opening of the cabinet will be 15.00" wide x 31.50" high.

The cabinet will include no adjustable shelves or traysin the cabinet interior.

The cabinet will include no louvers.

The cabinet will also provide access from outside the cab with one (1) reverse hinged double pan door painted to match the cab exterior with a locking D-ring latch with #1250 key. A pneumatic stay arm will be provided as a door stop. The exterior clear door opening will be 17.00" wide x

29.25" high.

The exterior access will be provided with a brushed stainless steel scuffplate on the lower door frame.

The cabinet will be constructed of smooth aluminum, and painted to match the cab interior.

Cabinet Light
There will be one (1) white LED strip light installed on the left side of the interior cabinet door opening. The lighting will be controlled by an automatic door switch. 0632949 Seat, Fwd Fcng C/C, LS Otbrd,
Pierce PSV, Hi-Back, Foldup,
SECONDARY, SFR/Enf

FORWARD FACING DRIVER SIDE OUTBOARD SEAT
There will be one (1) forward facing, foldup seat provided at the driver side outboard position in the crew cab. The seat back will be a high back style with 9 degree fixed recline angle. For optimal comfort, the seat will be a minimum of 15.00" from the front of the cushion to the face of the seat back and designed with EVC (elastomeric vibration control).

The seat will be furnished with a 3-point, shoulder type seat belt. 0819956 Cabinet, Fwd Fcng, Ctr, 32 W x 40 H
x 28 D, Web, SFR/Enf

FORWARD FACING CENTER CABINET
A forward facing cabinet will be provided in the crew cab at the center position.

The cabinet will be 32.00" wide x 40.00" high x 28.00" deep. The interior door will be web netting.

The netting will be made with 1.00" wide nylon material with 2.00" openings permanently fastened on the top with 1.00" cam buckle fasteners on the bottom to secure it. The clear door opening will be 29.50" wide x 37.00" high.

The cabinet will include two (2) infinitely adjustable shelves with a 1.25" flanged down lippainted to match the cab interior.

The cabinet will include no louvers.

The cabinet will be constructed of smooth aluminum, and painted to match the cab interior.

Cabinet Light
There will be one (1) white LED strip light installed horizontally above the interior cabinet door opening. The lighting will be controlled by a rocker switch on the front of the cabinet. 0632875 Seat, Fwd Fcng C/C, RS Otbrd,
Pierce PSV, Hi-Back, Foldup,
SECONDARY, SFR/Enf

FORWARD FACING PASSENGER SIDE OUTBOARD SEAT
There will be one (1) forward facing foldup seat provided at the passenger side outboard position in the crew cab. The seat back will be a high back style with 9 degree fixed recline angle. For optimal comfort, the seat will be a minimum of 15.00" from the front of the cushion to the face of the seat back and designed with EVC (elastomeric vibration control).

The seat will be furnished with a 3-point, shoulder type seat belt. 0566653 Upholstery, Seats In Cab, Turnout
Tuff

SEAT UPHOLSTERY
All seat upholstery will be gray Turnout Tuff material. 0511471 No SCBA Brackets Required In Cab
Seats, Imp/Vel, AXT 2010, Qtm
2010,Saber FR/Enf
0603866 Seat Belt, Dual Retractor,
ReadyReach, Saber FR/Enforcer

SEAT BELTS
All cab and tiller cab (if applicable) seating positions will have red seat belts. To provide quick, easy use for occupants wearing bunker gear, the female buckle and seat belt webbing length will meet or exceed the current edition of applicable NFPA and CAN/ULC - S515 standards.

The 3-point shoulder type seat belts will include height adjustment. This adjustment will optimize the belts effectiveness and comfort for the seated firefighter. The 3-point shoulder type seat belts will be furnished with dual automatic retractors that will provide ease of operation in the normal seating position.

The 3-point shoulder type belts will also include the ReadyReach D-loop assembly to the shoulder belt system. The ReadyReach feature adds an extender arm to the D-loop location placing the D-loop in a closer, easier to reach location.

Any flip up seats will include a 3-point shoulder type belts only.

To ensure safe operation, the seats will be equipped with seat belt sensors in the seat cushion and belt receptacle that will activate an alarm indicating a seat is occupied but not buckled. 0817557 Helmet Storage, Provided by Fire
Department, NFPA 2024

HELMET STORAGE PROVIDED BY FIRE DEPARTMENT
NFPA 1900, 2024 edition, section 11.1.8.4.1 requires a location for helmet storage be provided.

There is no helmet storage on the apparatus as manufactured. The fire department will provide a location for storage of helmets.

Bid #: 955 19 11.39
0647647 Lights, Dome, FRP Dual LED 4 Lts CAB DOME LIGHTS There will be four (4) dual LED dome lights with grey bezels provided. Two (2) lights will be mounted above the inside shoulder of the driver and officer and two (2) lights will be installed and located, one (1) on each side of the crew cab.

The color of the LED's will be red and white.

The white LED's will be controlled by the door switches and the lens switch.

The color LED's will be controlled by the lens switch.

In order to ensure exceptional illumination, each white LED dome light will provide a minimum of

10.1 foot-candles (fc) covering an entire 20.00" x 20.00" square seating position when mounted

40.00" above the seat.
0896451 Enhanced Software for Cab and
Crew Cab Dome Lts

ENHANCED SOFTWARE FOR CAB AND CREW CAB DOME LIGHTS
The cab and crew cab dome lights will remain on for 10 seconds for improved visibility after the doors are closed.

The dome lights will dim after 10 seconds or immediately if the vehicle's transmission is put into gear.
0626097 Light, Map, Sunnex HS76*-00 Series,
Swivel Joint, Clear Lens, Ceiling
Mount

MAP LIGHT
There will be one (1) Sunnex®, HS76*-00, halogen map light(s) with swivel joint base provided in the cab and located officer left shoulder area. Each map light will have a rectangular base with an on/off switch.

The light(s) will also be provided with no additional accessory.

The light switch(es) will be connected directly to the battery switched power. 0727913 Spotlight, Golight/RadioRay, Model
20**4GT, LED, 2 Lts

CAB SPOTLIGHT
There will be two (2) Golight, Model 20**4GT, white LED spotlights located on the cab roof, in front of the windshield, MATCH 28118. ALSO THE BRACKETS NEED .25" DRAIN HOLE IN EACH BOTTOM CORNER FOR DRAINAGE. The spotlights will be mounted on visor brackets.

These lights may be load managed when the parking brake is applied. 0650030 Controller, Spotlight, Golight, Wired
Dash Mount, 2 Lts
Spotlight Controller
There will be one (1) wired dash mounted remote provided for each spotlight. 0649967 Location, Spotlight Controller, Driver
and Officer, 2 Lts
Spotlight Controller Locations
The remotes to control the spotlights will be located one (1) within reach of the driver and one (1) within reach of the officer.
0625194 Handlts, (4) Koehler, BrightStar,
Responder 510318, light & charger,
12vdc

HAND HELD SPOTLIGHT
There will be four (4) Koehler, Model 510318, hand held lights with orange bodies and 12 volt charger units mounted match 28118, with the exception of the officer side light. Match the officer side with the provided photo..

The chargers will be hard wired to the chassis battery system. 0681751 Handlight, Streamlight, E- Flood
LiteBox, 45805 LED, 12v Charger,
Orange

HAND HELD LIGHT
There will be two (2) lights Streamlight E-Flood LiteBox, Model 45805, LED hand lights with the orange thermoplastic body and dual rear LEDs provided. These will be mounted top of the crew cab CENTER FORWARD FACING EMS compartment, leave loose until the final inspection.

The light will be provided with a 12 volt charger.
0603606 Cab Instruments, Ivory Gauges,
Chrome Bezels, Enf MUX

CAB INSTRUMENTATION
The cab instrument panel will include gauges, an LCD display, telltale indicator lamps, control switches, alarms, and a diagnostic panel. The function of the instrument panel controls and switches will be identified by a label adjacent to each item. Actuation of the headlight switch will illuminate the labels in low light conditions. Telltale indicator lamps will not be illuminated unless necessary. The cab instruments and controls will be conveniently located within the forward cab section, forward of the driver. The gauge assembly and switch panels are designed to be removable for ease of service and low cost of ownership.

Gauges
The gauge panel will include the following ten (10) ivory faced gauges with chrome bezels to monitor vehicle performance:

Voltmeter gauge (volts):

Low volts (11.8 VDC)
Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
High volts (15.5 VDC)
Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Very low volts (11.3 VDC)
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Very high volts (16.0 VDC)
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Engine Tachometer (RPM)
Speedometer MPH (Major Scale), KM/H (Minor Scale)
Bid #: 955 20 11.40
Fuel level gauge (Empty - Full in fractions):

Low fuel (1/8 full)
Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Very low fuel (1/32 full)
Red caution indicator on the information center with steady alarm Amber caution light on gauge assembly
Engine Oil pressure Gauge (PSI):

Low oil pressure to activate engine warning lights and alarms Red caution indicator on the information center with steady alarm Amber caution light on gauge assembly
Front Air Pressure Gauges (PSI):

Low air pressure to activate warning lights and alarm
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Rear Air Pressure Gauges (PSI):

Low air pressure to activate warning lights and alarm
Red warning indicator on the information center with a steady alarm Amber caution light on gauge assembly
Transmission Oil Temperature Gauge (Fahrenheit):

High transmission oil temperature activates warning lights and alarm Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Engine Coolant Temperature Gauge (Fahrenheit):

High engine temperature activates an engine warning light and alarms Amber caution indicator on the information center with intermittent alarm Amber caution light on gauge assembly
Diesel Exhaust Fluid Level Gauge (Empty - Full in fractions):

Low fluid (1/8 full)
Amber indicator light in gauge dial
All gauges will perform prove out at initial power-up to ensure proper performance.

Indicator Lamps
To promote safety, the following telltale indicator lamps will be located on the instrument panel in clear view of the driver. The indicator lamps will be "dead-front" design that is only visible when active. The colored indicator lights will have descriptive text or symbols.

The following amber telltale lamps will be present:

Low coolant
Trac cntl (traction control) (where applicable
Check engine
Check trans (check transmission
Aux brake overheat (Auxiliary brake overheat
Air rest (air restriction)
Caution (triangle symbol)
Water in fuel
DPF (engine diesel particulate filter regeneration)
Trailer ABS (where applicable)
Wait to start (where applicable)
HET (engine high exhaust temperature) (where applicable) ABS (antilock brake system)
MIL (engine emissions system malfunction indicator lamp) (where applicable) Side roll fault (where applicable)
Front air bag fault (where applicable)
The following red telltale lamps will be present:

Warning (stop sign symbol)
Seat belt
Parking brake
Stop engine
Rack down
The following green telltale lamps will be provided:

Left turn
Right turn
Battery on
The following blue telltale lamp will be provided:

High beam
Alarms
Audible steady tone warning alarm: A steady audible tone alarm will be provided whenever a warning message is present.

Audible pulsing tone caution alarm: A pulsing audible tone alarm (chime/chirp) will be provided whenever a caution message is present without a warning message being present.

Alarm silence: Any active audible alarm will be able to be silenced by holding the ignition switch at the top position for three (3) to five (5) seconds. For improved safety, silenced audible alarms will intermittently chirp every 30 seconds until the alarm condition no longer exists. The intermittent chirp will act as a reminder to the operator that a caution or warning condition still exists. Any new warning or caution condition will enable the steady or pulsing tones respectively.

Indicator Lamp and Alarm Prove-Out
A system will be provided which automatically tests telltale indicator lights and alarms located on the cab instrument panel. Telltale indicators and alarms will perform prove-out at initial power-up to ensure proper performance.

Control Switches
For ease of use, the following controls will be provided immediately adjacent to the cab instrument panel within easy reach of the driver. All switches will have backlit labels for low light applications.

Headlight/Parking light switch: A three (3)-position maintained rocker switch will be provided. The first switch position will deactivate all parking and headlights. The second switch position will activate the parking lights. The third switch will activate the headlights.

Panel back lighting intensity control switch: A three (3)-position momentary rocker switch will be provided. Pressing the top half of the switch, "Panel Up" increases the panel back Bid #: 955 21 11.41
lighting intensity and pressing the bottom half of the switch, "Panel Down" decreases the panel back lighting intensity. Pressing the half or bottom half of the switch several times will allow back lighting intensity to be gradually varied from minimum to maximum intensity level for ease of use.

Ignition switch: A three (3)-position maintained/momentary rocker switch will be provided.

The first switch position will turn off and deactivate vehicle ignition. The second switch position will activate vehicle ignition and will perform prove-out on the telltale indicators and alarms for 3 to 5 seconds after the switch is turned on. A green indicator lamp is activated with vehicle ignition. The third momentary position will temporarily silence all active cab alarms. An alarm "chirp" may continue as long as alarm condition exists.

Switching ignition to off position will terminate the alarm silence feature and reset function of cab alarm system.

Engine start switch: A two (2)-position momentary rocker switch will be provided. The first switch position is the default switch position. The second switch position will activate the vehicle's engine. The switch actuator is designed to prevent accidental activation.

Hazard switch will be provided on the instrument panel or on the steering column.

Heater, defroster, and air conditioning control panel.

Windshield wiper control will include low, high and intermittent modes.

Turn signal arm: A self-canceling turn signal with high beam headlight will be provided.

Parking brake control: An air actuated push/pull park brake control valve will be provided.

Chassis horn control: Activation of the chassis horn control will be provided through the center of the steering wheel.

High idle engagement switch: A momentary rocker switch with integral indicator lamp will be provided. The switch will activate and deactivate the high idle function. The "OK To Engage High Idle" indicator lamp must be active for the high idle function to engage. A green indicator lamp integral to the high idle engagement switch will indicate when the high idle function is engaged.
"OK To Engage High Idle" indicator lamp: A green indicator light will be provided next to the high idle activation switch to indicate that the interlocks have been met to allow high idle engagement.

Emergency switching will be controlled by a single emergency master switch that controls all emergency warning lights except those specified to have a dedicated switch.

An additional "Emergency Master" button will be provided on the lower left hand corner of the gauge panel to allow convenient control of the "Emergency Master" system from inside the driver's door when standing on the ground.

Custom Switch Panels
The design of cab instrumentation will allow for emergency lighting and other switches to be placed within easy reach of the operator thus improving safety. There will be positions for up to four (4) switch panels in the lower instrument console and up to six (6) switch panels in the overhead visor console. All switches have backlit labels for low light conditions.

Diagnostic Panel
A diagnostic panel will be accessible while standing on the ground and located inside the driver's side door left of the steering column. The diagnostic panel will allow diagnostic tools such as computers to connect to various vehicle systems for improved troubleshooting providing a lower cost of ownership. Diagnostic switches will allow ABS systems to provide blink codes should a problem exist.

The diagnostic panel will include the following:

Engine diagnostic port
Transmission diagnostic port
ABS diagnostic port
Roll sensor diagnostic port
Command Zone USB diagnostic port
ABS diagnostic switch (blink codes flashed on ABS telltale indicator) Diesel particulate filter regeneration switch (where applicable) Diesel particulate filter regeneration inhibit switch (where applicable) Cab LCD Display
A digital four (4)-row by 20-character dot matrix display will be integral to the gauge panel. The display will be capable of showing simple graphical images as well as text. The display will be split into three (3) sections. Each section will have a dedicated function. The upper left section will display the outside ambient temperature.

The upper right section will display the following, along with other configuration specific information:

Odometer
Trip mileage
PTO hours
Fuel consumption
Engine hours
The bottom section will display INFO, CAUTION, and WARNING messages. Text messages will automatically activate to describe the cause of an audible caution or warning alarm. The LCD will be capable of displaying multiple text messages should more than one caution or warning condition exist.
0509511 Air Restriction Indicator, Imp/Vel,
AXT, Dash CF, Enf MUX

AIR RESTRICTION INDICATOR
A high air restriction warning indicator light LCD message with amber warning indicator and audible alarm will be provided.

Bid #: 955 22 11.42
0543751 Light, Do Not Move Apparatus

"DO NOT MOVE APPARATUS" INDICATOR
A flashing red indicator light, located in the driving compartment, will be illuminated automatically per the current NFPA requirements. The light will be labeled "Do Not Move Apparatus If Light Is On."
The same circuit that activates the Do Not Move Apparatus indicator will activate a pulsing alarm when the parking brake is released.
0509042 Messages, Open Dr/DNMT, Color
Dsply,

DO NOT MOVE TRUCK MESSAGES
Messages will be displayed on the Command Zone™, color display located within sight of the driver whenever the Do Not Move Truck light is active. The messages will designate the item or items not in the stowed for vehicle travel position (parking brake disengaged).

The following messages will be displayed (where applicable):

Do Not Move Truck
DS Cab Door Open (Driver Side Cab Door Open)
PS Cab Door Open (Passenger's Side Cab Door Open)
DS Crew Cab Door Open (Driver Side Crew Cab Door Open)
PS Crew Cab Door Open (Passenger's Side Crew Cab Door Open) DS Body Door Open (Driver Side Body Door Open)
PS Body Door Open (Passenger's Side Body Door Open)
Rear Body Door Open
DS Ladder Rack Down (Driver Side Ladder Rack Down)
PS Ladder Rack Down (Passenger Side Ladder Rack Down)
Deck Gun Not Stowed
Lt Tower Not Stowed (Light Tower Not Stowed)
Fold Tank Not Stowed (Fold-A-Tank Not Stowed)
Aerial Not Stowed (Aerial Device Not Stowed)
Stabilizer Not Stowed
Steps Not Stowed
Handrail Not Stowed
Any other device that is opened, extended, or deployed that creates a hazard or is likely to cause major damage to the apparatus if the apparatus is moved will be displayed as a caution message after the parking brake is disengaged.
0611683 Switching, Cab Instrument Lower
Console & Overhead, Membrane,
Enforcer WiFi MUX

SWITCH PANELS
The emergency light switch panel will have a master switch for ease of use plus individual switches for selective control. Each switch panel will contain eight (8) membrane-type switches each rated for one million (1,000,000) cycles. Panels containing less than eight (8) switch assignments will include non-functioning black appliqués. The built-in switch panels will be located in the lower console or overhead console of the cab.

Additional switch panel(s) will be located in the overhead position(s) above the windshield or in designated locations on the lower instrument panel layout.

The switches will be membrane-type and also act as an integral indicator light. For quick, visual indication the entire surface of the switch will be illuminated white whenever back lighting is activated and illuminated green whenever the switch is active. An active illuminated switch will flash when interlock requirements are not met or device is actively being load managed. For ease of use, a two (2)-ply, scratch resistant laser engraved Gravoply label indicating the use of each switch will be placed in the center of the switch. The label will allow light to pass through the letters for ease of use in low light conditions.
0802940 Wiper Control, 2-Speed with
Intermittent, Saber FR/Enforcer

WIPER CONTROL
Wiper control will consist of a two (2)-speed windshield wiper control with intermittent feature and windshield washer controls. The control will be located above the ignition switch. 0820897 Wiring, Spare, 15 A 12V DC, Batt Dir,
2nd NFPA1900

SPARE CIRCUIT
There will be one (1) pair of wires, including a positive and a negative, installed on the apparatus.

The above wires will have the following features:

The positive wire will be connected directly to the isolated battery The negative wire will be connected to ground
Wires will be protected to 15 amps at 12 volts DC
Power and ground will terminate officer side dash area
Termination will be with 15 amp, power point plug with rubber cover Wires will be sized to 125 percent of the protection
Battery direct loads cannot be Load Managed
0820906 Wiring, Spare, 15 A 12V DC 2nd
NFPA1900

SPARE CIRCUIT
There will be three (3) pair of wires, including a positive and a negative, installed on the apparatus.

The above wires will have the following features:

The positive wire will be connected directly to the battery switched power The negative wire will be connected to ground
Wires will be protected to 15 amps at 12 volts DC
Power and ground will terminate DRIVER SIDE X 2, INSIDE CENTER FORWARD FACING

COMPARTMENT PER THE PROVIDED PIC
Termination will be with 15 amp, power point plug with rubber cover Wires will be sized to 125 percent of the protection
The circuit(s) may be load managed when the parking brake is set.

Bid #: 955 23 11.43
0820907 Wiring, Spare, 15 A 12V DC 3rd
NFPA1900

SPARE CIRCUIT
There will be seven (7) pair of wires, including a positive and a negative, installed on the apparatus.

The above wires will have the following features:

The positive wire will be connected directly to the battery switched power The negative wire will be connected to ground
Wires will be protected to 15 amps at 12 volts DC
Power and ground will terminate EACH BODY COMPARTMENT, LEAVE LOOSE WITH A 6' COIL Termination will be with 3/8" studs and plastic covers
Wires will be sized to 125 percent of the protection
The circuit(s) may be load managed when the parking brake is set. 0723827 SP Radio, AM/FM/Media Receiver,
Pioneer MVH-S720BHS

AM/FM/MEDIA RECEIVER
There will be one (1) Pioneer, Model MVH-S720BHS Digital Media Receiver with Enhanced Audio Functions, Pioneer Smart Sync App Compatibility, MIXTRAX®, Built-in Bluetooth®, HD Radio™ and SiriusXM-Ready™mounted in the cab per switch panel layout.

There will be one (1) pair of 5.25" speakers in the cab and one (1) pair of 5.25" speakers in the crew cab.

Antenna will be a roof-mounted rubber antenna located in an open space, on the cab roof. 0814201 Vehicle Information Center, 7" Color
Display, Touchscreen, MUX, CL714

INFORMATION CENTER
An information center employing a 7.00" diagonal touch screen color LCD display will be encased in an ABS plastic housing.

The information center will have the following specifications:

Operate in temperatures from -40 to 158 degrees Fahrenheit LCD optically bonded to hardened AR glass lens
Five weather resistant user interface switches
Grey with black accents
Sunlight Readable
Linux operating system
Minimum of 1000nits rated display
Display can be changed to an available foreign language A LCD display integral to the cab gauge panel will be included as outlined in the cab instrumentation area.

Programmed to read US Customary
General Screen Design
Where possible, background colors will be used to provide "At a Glance" vehicle information. If information provided on a screen is within acceptable limits, a green background will be used.

If a caution or warning situation arises the following will occur:

An amber background/text color will indicate a caution condition A red background/text color will indicate a warning condition The information center will utilize an "Alert Center" to display text messages for audible alarm tones. The text messages will be written to identify the item(s) causing the audible alarm to sound. If more than one (1) text message occurs, the messages will cycle every second until the problem(s) have been resolved. The background color for the "Alert Center" will change to indicate the severity of the "warning" message. If a warning and a caution condition occur simultaneously, the red background color will be shown for all alert center messages.

A label for each button will exist. The label will indicate the function for each active button for each screen. Buttons that are not utilized on specific screens will have a button label with no text or symbol.

Home/Transit Screen
This screen will display the following:

Vehicle Mitigation (if equipped)
Water Level (if the water level system includes compatible communications to the information center)
Foam Level (if the foam level system includes compatible communications to the information center)
Seat Belt Monitoring Screen
Tire Pressure Monitoring (if equipped)
Digital Speedometer
Active Alarms
On Scene Screen
This screen will display the following and will be auto activated with pump engaged (if equipped):

Battery Voltage
Fuel
Oil Pressure
Coolant Temperature
RPM
Water Level (if equipped)
Foam Level (if equipped)
Foam Concentration (if equipped)
Water Flow Rate (if equipped)
Water Used (if equipped)
Active Alarms
Virtual Buttons
There will be four (4) virtual switch panel screens that match the overhead and lower lighting and HVAC switch panels.

Page Screen
The page screen will display the following and allow the user to progress into other screens for further functionality:

Diagnostics
Faults
Listed by order of occurrence
Allows to sort by system
Bid #: 955 24 11.44
Interlock
Throttle Interlocks
Pump Interlocks (if equipped)
Aerial Interlocks (if equipped)
PTO Interlocks (if equipped)
Load Manager
A list of items to be load managed will be provided. The list will provide a description of the load.

The lower the priority numbers the earlier the device will be shed should a low voltage condition occur.

The screen will indicate if a load has been shed (disabled) or not shed. "At a glance" color features are utilized on this screen.

Systems
Command Zone
Module type and ID number
Module Version
Input or output number
Circuit number connected to that input or output
Status of the input or output
Power and Constant Current module diagnostic information Foam (if equipped)
Pressure Controller (if equipped)
Generator Frequency (if equipped)
Live Data
General Truck Data
Maintenance
Engine oil and filter
Transmission oil and filter
Pump oil (if equipped)
Foam (if equipped)
Aerial (if equipped)
Setup
Clock Setup
Date & Time
12 or 24 hour format
Set time and date
Backlight
Daytime
Night time
Sensitivity
Unit Selection
Home Screen
Virtual Button Setup
On Scene Screen Setup
Configure Video Mode
Set Video Contrast
Set Video Color
Set Video Tint
Do Not Move
The screen will indicate the approximate location and type of item that is open or is not stowed for travel. The actual status of the following devices will be indicated Driver Side Cab Door
Passenger's Side Cab Door
Driver Side Crew Cab Door
Passenger's Side Crew Cab Door
Driver Side Body Doors
Passenger's Side Body Doors
Rear Body Door(s)
Ladder Rack (if applicable)
Deck Gun (if applicable)
Light Tower (if applicable)
Hatch Door (if applicable)
Stabilizers (if applicable)
Steps (if applicable)
Notifications
View Active Alarms
Shows a list of all active alarms including date and time of the occurrence is shown with each alarm
Silence Alarms - All alarms are silenced
Timer Screen
HVAC (if equipped)
Tire Information (if equipped)
Ascendant Set Up Confirmation (if equipped)
Button functions and button labels may change with each screen.

Bid #: 955 25 11.45
0816633 Collision Mitigation, HAAS Alert
(R2V), HA7

COLLISION MITIGATION
There will be a HAAS Alert®, Model HA7 Responder-to-Vehicle (R2V) collision avoidance system provided on the apparatus. The HA7 cellular transponder module will be installed behind the cab windshield, as high and near to the center as practical, to allow clear visibility to the sky. The module dimensions are 5.40" long x 2.70" wide x 1.30" high, and operating temperature range is -40 degrees Celsius to 85 degrees Celsius.

The transponder will be connected to the vehicle's emergency master circuit and battery direct power and ground.

While responding with emergency lights on, the HA7 transponder sends alert messages via cellular network to motorists in the vicinity of the responding truck that are equipped with the WAZE app.

While on scene with emergency lights on, the HA7 transponder sends road hazard alerts to motorists in the vicinity of the truck that are equipped with the WAZE app.

The HA7 Responder-to-Vehicle (R2V) collision avoidance system will include the transponder and a 5 year cellular plan subscription.

Activation of the HAAS Alert system requires a representative of the customer to accept the End User License Agreement (EULA) via an on-line portal.
0606247 Vehicle Data Recorder w/CZ Display
Seat Belt Monitor

VEHICLE DATA RECORDER
There will be a vehicle data recorder (VDR) capable of reading and storing vehicle information provided.

The information stored on the VDR can be downloaded through a USB port mounted in a convenient location determined by cab model. A USB cable can be used to connect the VDR to a laptop to retrieve required information. The program to download the information from the VDR will be available to download on-line.

The vehicle data recorder will be capable of recording the following data via hardwired and/or CAN inputs:

Vehicle Speed - MPH
Acceleration - MPH/sec
Deceleration - MPH/sec
Engine Speed - RPM
Engine Throttle Position - % of Full Throttle
ABS Event - On/Off
Seat Occupied Status - Yes/No by Position
Seat Belt Buckled Status - Yes/No by Position
Master Optical Warning Device Switch - On/Off
Internal clock syncs the time and date when a laptop is connected.

Seat Belt Monitoring System
A seat belt monitoring system (SBMS) will be provided on the Command Zone™ color display.

The SBMS will be capable of monitoring up to 10 seating positions indicating the status of each seat position per the following:

Seat Occupied & Buckled = Green LED indicator illuminated Seat Occupied & Unbuckled = Red LED indicator with audible alarm No Occupant & Buckled = Red LED indicator with audible alarm No Occupant & Unbuckled = No indicator and no alarm
The seat belt monitoring screen will become active on the Command Zone color display when:

The home screen is active:
and there is any occupant seated but not buckled or any belt buckled with an occupant. and there are no other Do Not Move Apparatus conditions present. As soon as all Do Not Move Apparatus conditions are cleared, the SBMS will be activated.

The SBMS will include an audible alarm that will warn that an unbuckled occupant condition exists and the parking brake is released, or the transmission is not in park. 0696439 Antenna Mount, Custom Chassis,
Cable Routed to Instrument Panel
Area

RADIO ANTENNA MOUNT
There will be four (4) standard 1.125", 18 thread antenna-mounting base(s) installed two on each side per AD on the cab roof with high efficiency, low loss, coaxial cable(s) routed to the instrument panel area. A weatherproof cap will be installed on the mount. 0817058 Camera, Pierce, LS Mux, R Camera,
SD, CL714

VEHICLE CAMERA SYSTEM
There will be a color vehicle camera system provided with the following:

One (1) Standard Definition (SD) camera located at the rear of the apparatus, pointing rearward, displayed automatically with the vehicle in reverse.

The camera images will be displayed on the left side vehicle information center display. Audio from the microphone on the rear camera will be emitted by an amplified speaker with volume control located behind the driver seat.

The following components will be included:

One (1) SV-CW134639CAI Camera
All necessary cables
0814831 Not Required, Camera Switcher Camera Switcher
A camera switcher is not required.
0674566 Location, Rear Vision Camera

REAR CAMERA LOCATION
The rear camera will be located centered under the rear upper step, mounted on the rear body wall per the provided picture. .
0890416 Pierce Command Zone, Advanced
Electronics & Control System,

ELECTRICAL POWER CONTROL SYSTEM
The primary power distribution will be located forward of the officer's seating position and be Bid #: 955 26 11.46
Enforcer, WiFi CZT easily accessible while standing on the ground for simplified maintenance and troubleshooting.

Additional electrical distribution centers will be provided throughout the vehicle to house the vehicle's electrical power, circuit protection, and control components. The electrical distribution centers will be located strategically throughout the vehicle to minimize wire length. For ease of maintenance, all electrical distribution centers will be easily accessible. All distribution centers containing fuses, circuit breakers and/or relays will be easily accessible.

Distribution centers located throughout the vehicle will contain battery powered studs for supplying customer installed equipment thus providing a lower cost of ownership.

Circuit protection devices, which conform to SAE standards, will be utilized to protect electrical circuits. All circuit protection devices will be rated per NFPA requirements to prevent wire and component damage when subjected to extreme current overload. General protection circuit breakers will be Type-I automatic reset (continuously resetting). When required, automotive type fuses will be utilized to protect electronic equipment. Control relays and solenoid will have a direct current rating of 125 percent of the maximum current for which the circuit is protected per NFPA.

Solid-State Control System
A solid-state electronics based control system will be utilized to achieve advanced operation and control of the vehicle components. A fully computerized vehicle network will consist of electronic modules, electronic control modules to include black housings, a power indicator and status indicator located near their point of use to reduce harness lengths and improve reliability. The control system will comply with SAE J1939-11 recommended practices.

The control system will operate as a master-slave system whereas the main control module instructs all other system components. The system will contain patented Mission Critical software that maintains critical vehicle operations in the unlikely event of a main controller error. The system will utilize a Real Time Operating System (RTOS) fully compliant with OSEK/VDX™ specifications providing a lower cost of ownership.

For increased reliability and simplified use the control system modules will include the following attributes:

Green LED indicator light for module power
Red LED indicator light for network communication stability status Control system self test at activation and continually throughout vehicle operation No moving parts due to transistor logic
Software logic control for NFPA mandated safety interlocks and indicators Integrated electrical system load management without additional components Integrated electrical load sequencing system without additional components Customized control software to the vehicle's configuration Factory and field programmable to accommodate changes to the vehicle's operating parameters To assure long life and operation in a broad range of environmental conditions, the solid-state control system modules will meet the following specifications:

Module circuit board will meet SAE J771 specifications
Operating temperature from -40 degrees Celsius to +70 degrees Celsius Storage temperature from -40 degrees Celsius to +70 degrees Celsius Vibration to 50g
IP67 rated enclosure (Totally protected against dust and also protected against the effect of temporary immersion between 15 centimeters and one (1) meter) Operating voltage from eight (8) volts to 32 volts DC
The main controller will activate status indicators and audible alarms designed to provide warning of problems before they become critical.

Circuit Protection and Control Diagram
Copies of all job-specific, computer network input and output (I/O) connections will be provided with each chassis. The sheets will indicate the function of each module connection point, circuit protection information (where applicable), wire numbers, wire colors and load management information.

On-Board Electrical System Diagnostics
The on-board information center will include the following diagnostic information:

Text description of active warning or caution alarms
Simplified warning indicators
Amber caution indication with intermittent alarm
Red warning indication with steady tone alarm
Advanced diagnostic feature will be provided in this control system. From the Command Zone display or connected wireless device, these features allow the user to monitor the real-time status of every input or output on the vehicle. It also allows users logged in as an administrator to force on inputs or outputs to assist the troubleshooting process.

TCU Module with WiFi
An in cab module will provide WiFi wireless interface and data logging capability. The WiFi interface will comply with IEEE 802.11 b/g/n capabilities while communicating at 2.4 Gigahertz.

The module will communicate through a white WiFi antenna allowing a line of site communication range of up to 300 feet with a roof mounted antenna.

The module will transmit a password protected web page to a WiFi enabled device (i.e. most smart phones, tablets or laptops) allowing two levels of user interaction. The firefighter level will allow vehicle monitoring of the vehicle and firefighting systems on the apparatus. The technician level will allow diagnostic access to inputs and outputs installed on the Command Zone™, control and information system.

The TCU capability will record faults from the engine, transmission, ABS and Command Zone™, control and information systems as they occur. No other data will be recorded at the time the fault occurs. The data TCU will provide up to 2 Gigabytes of data storage.

The TCU will provide a means to download the TCU information and update software in the device.

Indicator Light and Alarm Prove-Out System
A system will be provided which automatically tests basic indicator lights and alarms located on the cab instrument panel.

Voltage Monitor System
A voltage monitoring system will be provided to indicate the status of the battery system connected to the vehicle's electrical load. The system will provide visual and audible warning when the system voltage is below or above optimum levels.

The alarm will activate if the system falls below 11.8 volts DC for more than two (2) minutes.

Dedicated Radio Equipment Connection Points
There will be three (3) studs provided in the primary power distribution center located in front of Bid #: 955 27 11.47
the officer for two-way radio equipment. The studs will consist of the following:
12-volt 40-amp battery switched power
12-volt 60-amp ignition switched power
12-volt 60-amp direct battery power
There will also be a 12-volt 100-amp ground stud located in or adjacent to the power distribution center.

EMI/RFI Protection
To prevent erroneous signals from crosstalk contamination and interference, the electrical system will meet, at a minimum, SAE J551/2, thus reducing undesired electromagnetic and radio frequency emissions. An advanced electrical system will be used to ensure radiated and conducted electromagnetic interference (EMI) or radio frequency interference (RFI) emissions are suppressed at their source.

The apparatus will have the ability to operate in the electromagnetic environment typically found in fire ground operations to ensure clean operations. The electrical system will meet, without exceptions, electromagnetic susceptibility conforming to SAE J1113/25 Region 1, Class C EMR for 10KHz-1GHz to 100 Volts/Meter. The vehicle OEM, upon request, will provide EMC testing reports from testing conducted on an entire apparatus and will certify that the vehicle meets SAE J551/2 and SAE J1113/25 Region 1, Class C EMR for 10KHz-1GHz to 100 Volts/Meter requirements. Component and partial (incomplete) vehicle testing is not adequate as overall vehicle design can impact test results and thus is not acceptable by itself.

EMI/RFI susceptibility will be controlled by applying appropriate circuit designs and shielding. The electrical system will be designed for full compatibility with low-level control signals and highpowered two-way radio communication systems. Harness and cable routing will be given careful attention to minimize the potential for conducting and radiated EMI/RFI susceptibility. 0896456 Prognostics, Electrical System

ELECTRICAL SYSTEM PROGNOSTICS
There will be a software based vehicle tool provided to predict remaining life of the vehicles critical fluid and events.

The system will send automatic indications to the Command Zone™ information center and/or wireless enabled devices to proactively alert of upcoming service intervals.

Prognostics will include the following:

Engine oil and filter
Transmission oil and filter
0624253 Electrical System, Enforcer MUX

ELECTRICAL
All 12-volt electrical equipment installed by the apparatus manufacturer will conform to modern automotive practices. All wiring will be high temperature crosslink type. Wiring will be run, in loom or conduit, where exposed and have grommets where wire passes through sheet metal.

Automatic reset circuit breakers will be provided which conform to SAE Standards. Wiring will be color, function and number coded. Function and number codes will be continuously imprinted on all wiring harness conductors at 2.00" intervals. Exterior exposed wire connectors will be positive locking, and environmentally sealed to withstand elements such as temperature extremes, moisture and automotive fluids.

Electrical wiring and equipment will be installed utilizing the following guidelines:

All holes made in the roof will be caulked with silicon. Large fender washers, liberally caulked, will be used when fastening equipment to the underside of the cab roof.

Any electrical component that is installed in an exposed area will be mounted in a manner that will not allow moisture to accumulate in it. Exposed area will be defined as any location outside of the cab or body.

Electrical components designed to be removed for maintenance will not be fastened with nuts and bolts. Metal screws will be used in mounting these devices. Also a coil of wire will be provided behind the appliance to allow them to be pulled away from mounting area for inspection and service work.

Corrosion preventative compound will be applied to all terminal plugs located outside of the cab or body. All non-waterproof connections will require this compound in the plug to prevent corrosion and for easy separation (of the plug).

All lights that have their sockets in a weather exposed area will have corrosion preventative compound added to the socket terminal area.

All electrical terminals in exposed areas will have silicon applied completely over the metal portion of the terminal.

All lights and reflectors, required to comply with Federal Motor Vehicle Safety Standard #108, will be furnished. Rear identification lights will be recessed mounted for protection. Lights and wiring mounted in the rear bulkheads will be protected from damage by installing a false bulkhead inside the rear compartments.

An operational test will be conducted to ensure that any equipment that is permanently attached to the electrical system is properly connected and in working order.

The results of the tests will be recorded and provided to the purchaser at time of delivery.

Bid #: 955 28 11.48
0079205 Batteries, (5) Stryten/Exide Grp 31,
950 CCA each, (1) Iso Bat, Threaded
Stud

BATTERY SYSTEM
Five (5) 12 volt, Stryten/Exide, Model 31S950X3W, group 31 batteries that include the following features will be provided:
950 CCA, cold cranking amps
190 amp reserve capacity
High cycle
Rating of 4750 CCA at 0 degrees Fahrenheit
950 minutes of reserve capacity
Threaded stainless steel studs
Each battery case will be a black polypropylene material with a vertically ribbed container for increased vibration resistance. The cover will be manifold vented with a central venting location to allow a 45 degree tilt capacity.

The inside of each battery will consist of a "maintenance free" grid construction with poly wrapped separators and a flooded epoxy bottom anchoring for maximum vibration resistance.

ISOLATED BATTERY
One (1) 12 volt, Exide, Model 31S950X3W, battery will be provided for voltage sensitive components. A battery isolator appropriately suited for the battery capacity will be supplied. 0008621 Battery System, Single Start, All
Custom Chassis

BATTERY SYSTEM
There will be a single starting system with an ignition switch and starter button provided and located on the cab instrument panel.

MASTER BATTERY SWITCH
There will be a master battery switch provided within the cab within easy reach of the driver to activate the battery system.

An indicator light will be provided on the instrument panel to notify the driver of the status of the battery system.
0002698 Battery Compartment,
Saber/Enforcer

BATTERY COMPARTMENTS
Batteries will be placed on non-corrosive mats and be stored in well ventilated compartments located under the cab and bolted directly to the chassis frame. The battery boxes will have reinforced sides. The battery compartments will be constructed of 0.188" steel plate and be designed to accommodate a maximum of three (3) group 31 batteries in each compartment. The battery hold-downs will be of a non-corrosive material. All bolts and nuts will be stainless steel.

Heavy-duty, 2/0 gauge, color coded battery cables will be provided. Battery terminal connections will be coated with anti-corrosion compound.

Battery solenoid terminal connections will be encapsulated with semi-permanent rubberized compound.

JUMPER STUDS
One (1) set of battery jumper studs with plastic color-coded covers will be included on the battery compartments.
0806076 Charger, Sngl Sys, Blue Sea P12,
7532, 40 Amp

BATTERY CHARGER
There will be a Blue Sea Model P12, battery charger provided.

The charger will have a maximum output of 40 amps and a fully automatic regulation.

The battery charger will be wired to the AC shoreline inlet through an AC receptacle adjacent to the battery charger.
0814869 Location, Cab, Charger, Behind
Driver Seat
The battery charger will be located in the cab behind the driver seat. 0812519 Panel, Charger Display, Blue Sea,
7517

REMOTE CONTROL PANEL - BATTERY CHARGER
There will be a Blue Sea™, Battery Charger Display Model 7517 included. 0814942 Location, Cab, Ind/Remote, Driver's
Seat with Bracket
The battery charger indicator will be located near the driver's seat riser with special bracketry. 0782026 Shoreline, 20A 120V, Blue Sea Sure
Eject 7851

SHORELINE INLET
There will be one (1) Blue Sea Sure Eject™ part number 7851, 20 amp 120 volt AC shoreline inlet provided to operate the dedicated 120 volt AC circuits on the apparatus.

The shoreline will be connected to battery charger and engine heater.

The shoreline inlet cover color to be red.

The connector body will be released from the inlet when the apparatus engine start button is activated.

There will be a mating connector body supplied with the loose equipment.

There will be a label installed near the inlet(s) that state the following:

Line Voltage
Current Ratting (amps)
Phase
Frequency
0026800 Shoreline Location The shoreline receptacle will be located in the driver side lower step well of cab.

Bid #: 955 29 11.49
0647728 Alternator, 430 amp, Delco Remy
55SI

ALTERNATOR
A Delco Remy®, Model 55SI, alternator will be provided. It will have a rated output current of 430 amps, as measured by SAE method J56. The alternator will feature an integral regulator and rectifier system that has been tested and qualified to an ambient temperature of 257 degrees Fahrenheit (125 degrees Celsius). The alternator will be connected to the power and ground distribution system with heavy-duty cables sized to carry the full rated alternator output. 0818490 SP Wiring, Customer Installed Solar
Panel & Controller, Sunforce
Crystalline w/Cntl

CUSTOMER SOLAR PANEL WIRING
Wiring/circuit protection will be installed to accommodate a customer installed one (1) Sunforce® Crystalline, Model 37150, 150 watt 12V DC solar panel provided on the cab roof MATCH 28118 AND PHOTO IN JOB FOLDER and one (1) Sunforce®, Model 60032, 12V DC 30 amp digital solar charge controller provided in the cab located MATCH 28118 AND PHOTO IN JOB FOLDER.

There will be a disconnect switch located MATCH 28118 AND PHOTO IN JOB FOLDER provided to activate the charging of the chassis batteries.
0784767 Load Manager/Sequencer, MUX

ELECTRONIC LOAD MANAGER
An electronic load management (ELM) system will be provided that monitors the vehicles 12-volt electrical system, automatically reducing the electrical load in the event of a low voltage condition, and automatically restoring the shed electrical loads when a low voltage condition expires. This ensures the integrity of the electrical system.

For improved reliability and ease of use, the load manager system will be an integral part of the vehicle's solid state control system requiring no additional components to perform load management tasks. Load management systems which require additional components will not be allowed.

The load manager system will be activated when the battery switch is on , the parking brake is applied and a switch in the cab on the switch panel is on.

The system will include the following features:

System voltage monitoring
A shed load will remain inactive for a minimum of five minutes to prevent the load from cycling on and off.

Eight available electronic load shedding levels.

Priority levels can be set for individual outputs.

High Idle to activate 30 seconds after engine start up and activate "Load Man Hi-Idle On" label on the information center where applicable, before any electric loads are deactivated.

Individual switch "on" indicator to flash when the particular load has been shed.

The information center indicates system voltage.

The information center, where applicable, includes a "Load Manager" screen indicating the following:

Load managed list, with priority levels and item condition.

Individual load managed item condition:

ON = not shed
SHED = shed

SEQUENCER
A sequencer will be provided that automatically activates and deactivates vehicle loads in a preset sequence thereby protecting the alternator from power surges. This sequencer operation will allow a gradual increase or decrease in alternator output, rather than loading or dumping the entire 12 volt load to prolong the life of the alternator.

For improved reliability and ease of use, the load sequencing system will be an integral part of the vehicle's solid state control system requiring no additional components to perform load sequencing tasks. Load sequencing systems which require additional components will not be allowed.

Emergency light sequencing will operate in conjunction with the emergency master light switch.

When the emergency master switch is activated, the individually switched emergency light groups will be activated one by one at half-second intervals. Sequenced emergency light switch indicators will flash while waiting for activation.

When the emergency master switch is deactivated, the sequencer will deactivate the warning light loads in the reverse order.

Sequencing of the following items will also occur, in conjunction with the ignition switch, at halfsecond intervals:

Cab Heater and Air Conditioning
Crew Cab Heater (if applicable)
Crew Cab Air Conditioning (if applicable)
Exhaust Fans (if applicable)
Third Evaporator (if applicable)
0783153 Headlights, Rect LED, JW Spkr Evo
2, AXT/DCF/Enf/Imp/Sab/Vel

HEADLIGHTS
There will be four (4) JW Speaker®, Model 8800, 4" x 6" rectangular LED lights mounted in the front quad style, chrome housing on each side of the cab grille:
the outside light on each side will contain a part number 055***1 low beam module the inside light on each side will contain a part number 055***1 high beam module the headlights to include chrome bezels
The low beam lights will be activated when the headlight switch is on.

The high beam and low beam lights will be activated when the headlight switch and the high beam switch is activated.
0625953 Light, Directional, Wln 600 Cmb, Cab
Crn, Wrp Bzl Out HD Lts, Enf, Sab
FR

DIRECTIONAL LIGHTS
There will be two (2) Whelen 600 series, LED combination directional/marker lights provided. The lights will be located on the outside cab corners, next to the headlights.

The color of the lenses will be clear.

Bid #: 955 30 11.50
0620054 Light, Directional/Marker,
Intermediate, Weldon 9186-8580-29
LED 2lts

INTERMEDIATE LIGHT
There will be two (2) Weldon, Model 9186-8580-29, amber LED turn signal marker lights furnished, one (1) each side, in the rear fender panel. The light will double as a turn signal and marker light.
0735474 Lights, Clearance/Marker/ID, Front,
P25 LED 7 Lts, Saber FR/Enforcer

CAB CLEARANCE/MARKER/ID LIGHTS
There will be seven (7) amber LED lights provided per the following:

Three (3) amber LED identification lights will be installed in the center of the cab above the windshield.

Two (2) amber LED clearance lights will be installed, one (1) on each outboard side of the cab above the windshield as close to the outside of the apparatus as practical.

Two (2) amber LED clearance lights will be installed, one (1) on each side of the cab as high and far forward as practical.

The lights will be installed without guards.
0625210 Lights, Directional, Cab Front Side,
Truck-Lite 19036Y LED, AXT/Enf

FRONT CAB SIDE CLEARANCE/MARKER LIGHTS
There will be two (2) Truck-Lite®, Model 19036Y, amber LED lights installed to the outside of the chrome wrap around bezel, one (1) on each side of the cab.

The lights will activate as additional directional lights with the corresponding directional circuit. 0563675 Lights, Clearance/Marker/ID, Rear,
Truck-Lite 33050R LED 7Lts

REAR CLEARANCE/MARKER/ID LIGHTING
There will be three (3) Truck-Lite®, Model 33050R, LED lights used as identification lights recessed and located at the rear of the apparatus per the following:

As close as practical to the vertical centerline
Centers spaced not less than 6.00" or more than 12.00" apart Red in color
All at the same height
There will be two (2) Truck-Lite, Model 33050R, LED lights recessed at the rear of the apparatus used as clearance lights located at the rear of the apparatus per the following:

To indicate the overall width of the vehicle
One (1) each side of the vertical centerline
As near the top as practical
Red in color
To be visible from the rear
All at the same height
There will be two (2) Truck-Lite, Model 33050R, LED lights recessed on the side of the apparatus as marker lights as close to the rear as practical per the following:

To indicate the overall length of the vehicle
One (1) each side of the vertical centerline
As near the top as practical
Red in color
To be visible from the side
All at the same height
There will be two (2) red reflectors located on the rear of the truck facing to the rear. One (1) each side, as far to the outside as practical, at a minimum of 15.00", but no more than 60.00", above the ground.

There will be two (2) red reflectors located on the side of the truck facing to the side. One (1) each side, as far to the rear as practical, at a minimum of 15.00", but no more than 60.00", above the ground.

Per FMVSS 108 and CMVSS 108 requirements.
0804514 Lights, Tail, Wln M62BTT* Red
Stop/Tail & M62T* Amber Dir Arw For
Hsg

REAR FMVSS LIGHTING
The rear stop/tail and directional lighting included in the rear tail light housing will include the following:

Two (2) Whelen®, Model M62BTT, 4.30" high x 6.70" wide x 1.40" deep brake/tail lights with red LEDs
Two (2) Whelen, Model M62T, 4.30" high x 6.70" wide x 1.40" deep directional lights with amber LEDs. The directional lights will be set to Steady On (Arrow) flash pattern.

The lens color(s) to be the same as the LEDs.
0806466 Lights, Backup, Wln M62BU, LED,
For Tail Lt Housing
There will be two (2) Whelen Model M62BU, LED backup lights provided in the tail light housing. 0889577 Bracket, License Plate & Light, P25
LED, Stainless Brkt

LICENSE PLATE BRACKET
One (1) license plate bracket constructed of stainless steel will be provided at the rear of the apparatus.

One (1) white LED light with chrome housing will be provided to illuminate the license plate. A stainless steel light shield will be provided over the light that will direct illumination downward, preventing white light to the rear.
0556842 Bezels, Wln, (2) M6 Chrome Pierce,
For mtg (4) Wln M6 lights

LIGHTING BEZEL
There will be two (2) Whelen, Model M6FCV4P, four (4) place chromed ABS housings with Pierce logos provided for the rear M6 series stop/tail, directional, back up, scene lights or warning lights.

Bid #: 955 31 11.51
0589905 Alarm, Back-up Warning, PRECO
1040

BACK-UP ALARM
A PRECO, Model 1040, solid-state electronic audible back-up alarm that actuates when the truck is shifted into reverse will be provided. The device will sound at 60 pulses per minute and automatically adjust its volume to maintain a minimum ten (10) dBA above surrounding environmental noise levels.
0626588 Lights, Perimeter Cab, TecNiq T10-
LC00-1 15" LED 4Dr

CAB PERIMETER SCENE LIGHTS
There will be four (4) TecNiq, Model T10-LC00-1, 15.00" lights with white LEDs and 45 degree stainless steel brackets provided per the following:
one (1) under the driver's side cab access step
one (1) under the passenger's side cab access step
one (1) under the passenger's side crew cab access step one (1) under the driver's side crew cab access step
The lights will be activated when the battery switch is on, when the respective door is open and by the same control selected for the body perimeter lights. 0617901 Lights, Perimeter Pump House,
TecNiq T10-LC00-1 15" LED 2lts

PUMP HOUSE PERIMETER LIGHTS
There will be two (2) TecNiq, Model T10-LC00-1, 15.00" white 12 volt DC LED weatherproof strip lights provided under the pump panel running boards, one (1) each side.

The lights will be controlled by the same means as the body perimeter lights. 0626579 Lights, Perimeter Body, TecNiq T10-
LC00-1 15" LED 2lts, Rear Step

BODY PERIMETER SCENE LIGHTS
There will be two (2) TecNiq, Model T10-LC00-1, 15.00" 12 volt DC LED strip lights provided at the rear step area of the body, one (1) each side shining to the rear.

The perimeter scene lights will be activated when a switch within reach of the driver is activated, a switch within reach of the passenger is activated, the parking brake is applied and either directional light is activated, activating all side facing perimeter lights with a 10 second delay after directional is deactivated.
0617802 Lights, Perimeter, TecNiq T10-LC00-1
15" LED

ADDITIONAL PERIMETER LIGHTS
There will be two (2) TecNiq, Model T10-LC00-1, 1.25" high x 15.00" long white LED light(s) provided under UNDER LS1 AND RS1.

These additional lights will be controlled with the other body perimeter lights. 0896454 Enhanced Software for Perimeter Lts

ENHANCED SOFTWARE FOR PERIMETER LIGHTS
All perimeter lights will be deactivated when the parking brake is released unless alternate control is selected.

The cab and crew cab perimeter lights will remain on for ten (10) seconds for improved visibility after the doors closed.
0556360 Lights, Step, P25 LED 4lts, Pump Pnl
Sw

STEP LIGHTS
Four (4) white LED step lights will be provided. One (1) step light will be provided on each side, on the front compartment face and two (2) step lights at the rear to illuminate the tailboard.

In order to ensure exceptional illumination, each light will provide a minimum of 25 foot-candles (fc) covering an entire 15.00" x 15.00" square placed 10.00" below the light and a minimum of 1.5 fc covering an entire 30.00" x 30.00" square at the same 10.00" distance below the light.

These step lights will be actuated with the pump panel light switch.

All other steps on the apparatus will be illuminated per the current edition of applicable NFPA standards.
0776357 Light, Visor, Wln, 12V P*H2* Pioneer,
Cnt Feature, 1st
12 VOLT LIGHTING
There will be one (1) Whelen® Model P*H2*, 17,750 lumens 12 volt DC light(s) with a combination of flood and spot optics provided on the front visor, centered.

The housing(s) painted parts of this light assembly to be white.

The light(s) will be controlled by a switch at the driver's side switch panel and by a switch at the passenger's side switch panel.

These light(s) may be load managed when the parking brake is applied. 0727946 Lights, Wln, S30M** 30" 12VDC LED,
RS Cab, Mt Fet
12 VOLT DC SCENE LIGHTS
There will be one (1) Whelen® Model S30M**, 12,960 lumens 30.00" 12 volt DC light(s) with white LEDs provided on the right side of the cab roof located, RS CAB ROOF OVER THE OFFICER DOOR. The painted parts of this light assembly to be white. The light(s) to be installed with flat horizontal mounts.

The light(s) will include the following:

Six (6) scene light modules with white LEDs
Three (3) amber LEDs as marker lights
Two (2) additional LED modules. The additional modules to be two (2) scene light modules with white LEDs.

The lights will be activated per the following:

The amber marker lights not activated.

The scene LEDs will be controlled by a switch at the driver's side switch panel, by a switch at the left side pump panel and by a switch at the passenger's side switch panel.

There will be a switch in the cab on the switch panel to control the flashing or spot LED modules.

The light(s) may be load managed when the parking brake is applied.

Bid #: 955 32 11.52
0727947 Lights, Wln, S30M** 30" 12VDC LED,
LS Cab, Mt Fet
12 VOLT DC SCENE LIGHTS
There will be one (1) Whelen® Model S30M**, 12,960 lumens 30.00" 12 volt DC light(s) with white LEDs provided on the left side of the cab roof located, LS CAB ROOF OVER THE DRIVER DOOR. The painted parts of this light assembly to be white. The light(s) to be installed with flat horizontal mounts.

The light(s) will include the following:

Six (6) scene light modules with white LEDs
Three (3) amber LEDs as marker lights
Two (2) additional LED modules. The additional modules to be two (2) scene light modules with white LEDs.

The lights will be activated per the following:

The amber marker lights not activated.

The scene LEDs will be controlled by a switch at the driver's side switch panel, by a switch at the left side pump panel and by a switch at the passenger's side switch panel.

There will be a switch in the cab on the switch panel to control the flashing or spot LED modules.

The light(s) may be load managed when the parking brake is applied. 0774336 Lights, Wln, P*H1* Pioneer, 12 VDC,
1st
12 VOLT LIGHTING
There will be two (2) Whelen® Model P*H1*, 8,875 lumens 12 volt DC LED light(s) with flood optics installed on the apparatus located, rear bulkhead as high as possible.

The painted parts of this light assembly to be white.

The light(s) to be installed in a 15 degree vertical recessed bracket.

The lights will be controlled by a switch at the driver's side switch panel, by a switch at the passenger's side switch panel and by a switch in a recessed cup located at the driver's side rear bulkhead.

The light(s) may be load managed when the parking brake is applied. 0748793 Lights, Wln, S44M** 44" 12VDC, RS
Body
12 VOLT LIGHTING
There will be one (1) Whelen® Model S44M**, 19,440 lumens 44.00" 12 volt DC light(s) with white LEDs provided on the right side of the body located, RS CATWALK OUTBOARD AS FAR AS POSSIBLE, CENTERED OVER RS2. The painted parts of this light assembly to be white.

The light(s) will include the following:
10 scene light modules with white LEDs
Three (3) amber LEDs as marker lights
Two (2) additional LED modules. The additional modules to be two (2) scene light modules with white LEDs.

The lights will be activated per the following:

The amber marker lights not activated.

The scene LEDs will be controlled by the same control that has been selected for the passenger's side scene light(s).

There will be a switch in the cab on the switch panel to control the flashing warning LED modules when selected.

The light(s) may be load managed when the parking brake is applied. 0748795 Lights, Wln, S44M** 44" 12VDC, LS
Body
12 VOLT LIGHTING
There will be one (1) Whelen® Model S44M**, 19,440 lumens 44.00" 12 volt DC light(s) with white LEDs provided on the left side of the body located, LS CATWALK OUTBOARD AS FAR AS POSSIBLE, CENTERED OVER LS2. The painted parts of this light assembly to be white.

The light(s) will include the following:
10 scene light modules with white LEDs
Three (3) amber LEDs as marker lights
Two (2) additional LED modules. The additional modules to be two (2) scene light modules with white LEDs.

The lights will be activated per the following:

The amber marker lights not activated.

The scene LEDs will be controlled by the same control that has been selected for the driver's side scene light(s).

There will be a switch in the cab on the switch panel to control the flashing warning LED modules when selected.

The light(s) may be load managed when the parking brake is applied. 0532358 Not Required, Deck Lights, Other
Hose Bed & Rear Lighting

0768474 Lights, Hose Bed, Below Alum Cvr,
Amdor AY-LB-12HW040, 40" LED 4lts

LIGHTS BELOW HOSE BED COVER
There will be four (4) Amdor Model AY-LB-12HW040, 700 lumens, 40.00" white LED lights provided to illuminate the hose bed area.

Two (2) LED light strips will be installed on the driver's side hose bed cover 30.00" from the front and rear of the hose bed, as close to the hinge as practical.

Two (2) LED light strips will be installed on the passenger's side hose bed cover 30.00" from the front and rear of the hose bed, as close to the hinge as practical.

The lights will be activated when the battery switch is on, and when the hosebed cover is raised. 0645677 Lights, Not Required, Rear Work, Alt.
12 Volt Lights At Rear Body
Bid #: 955 33 11.53
0892704 Lights, Walk Surf, 8-P25 LED, Hose
Bed Cover, Overall Height
Restrictions

WALKING SURFACE LIGHT
There will be eight (8) P25 12 volt DC LED lights with chrome housing provided on the hose bed cover to illuminate the walking surface. The lights will be located near the hose bed cover hinges evenly spaced four (4) on each side. The lights will be activated when the body step lights are on. 0060115 Pumper, Medium, Aluminum, 2nd
Gen
0554271 Body Skirt Height, 20"

0028244 Tank, Water, 500 Gallon, Poly, Med

WATER TANK
Booster tank will have a capacity of 500 gallons and be constructed of polypropylene plastic by United Plastic Fabricating, Incorporated.

Tank joints and seams will be nitrogen welded inside and out.

Tank will be baffled in accordance with the current edition of applicable NFPA standards.

Baffles will have vent openings at both the top and bottom to permit movement of air and water between compartments.

Longitudinal partitions will be constructed of .38" polypropylene plastic and will extend from the bottom of the tank through the top cover to allow for positive welding.

Transverse partitions will extend from 4.00" off the bottom of the tank to the underside of the top cover.

All partitions will interlock and will be welded to the tank bottom and sides.

Tank top will be constructed of .50" polypropylene. It will be recessed .38" and will be welded to the tank sides and the longitudinal partitions.

Tank top will be sufficiently supported to keep it rigid during fast filling conditions.

Construction will include 2.00" polypropylene dowels spaced no more than 30.00" apart and welded to the transverse partitions. Two (2) of the dowels will be drilled and tapped (.50" diameter, 13.00" deep) to accommodate lifting eyes.

A sump that will be sized dependent on the tank to pump plumbing will be provided at the bottom of the water tank.

Sump will include a drain plug and the tank outlet.

Tank will be installed in a fabricated cradle assembly constructed of structural steel.

Sufficient crossmembers will be provided to properly support bottom of tank. Crossmembers will be constructed of steel bar channel or rectangular tubing.

Tank will "float" in cradle to avoid torsional stress caused by chassis frame flexing. Rubber cushions, .50" thick x 3.00" wide, will be placed on all horizontal surfaces that the tank rests on.

Stops or other provision will be provided to prevent an empty tank from bouncing excessively while moving vehicle.

Mounting system will be approved by the tank manufacturer. 0003405 Overflow, 4.00" Water Tank, Poly

Fill tower will be constructed of .50" polypropylene and will be a minimum of 8.00" wide x 14.00" long.

Fill tower will be furnished with a .25" thick polypropylene screen and a hinged cover.

An overflow pipe, constructed of 4.00" schedule 40 polypropylene, will be installed approximately halfway down the fill tower and extend through the water tank and exit to the rear of the rear axle. 0028104 Foam Cell Required
0662467 Modified Poly Tank, Raised Tee, One
Side
0553729 Not Required, Restraint, Water Tank,
Heavy Duty
0003429 Not Required, Direct Tank Fill

0003424 Not Required, Dump Valve

0048710 Not Required, Jet Assist

0030007 Not Required, Dump Valve Chute

0514778 Not Required, Switch, Tank Dump
Master
Bid #: 955 34 11.54
0126633 Hose Bed, Aluminum, Pumper

HOSE BED
The hose bed will be fabricated of .125"-5052 aluminum with a nominal 38,000 psi tensile strength.

Upper and rear edges of side panels will have a double break for rigidity.

The upper inside area of the beavertails will be covered with brushed stainless steel to prevent damage to painted surface when hose is removed.

Flooring of the hose bed will be removable aluminum grating with the top surface corrugated to aid in hose aeration. The grating slats will be a minimum of 0.50" x 4.50" with spacing between slats for hose ventilation.
0723549 Painted Hose Bed The hose bed interior walls will be painted to match the lower body color. 0003481 Hose Bed Capacity, Special

Hose bed will accommodate 200' of 2.50" DJ hose, 400' of 1.50" forestry hose, 800' of 4.00" DJ hose, 200' of 1.75" DJ hose, 800' of 2.50" DJ hose.
0003488 Divider, Hose Bed, Unpainted

HOSE BED DIVIDER
Four (4) hosebed dividers will be furnished for separating hose.

Each divider will be constructed of a .125" brushed aluminum sheet fitted and fastened into a slotted, 1.50" diameter radiused extrusion along the top, bottom, and rear edge.

Divider will be fully adjustable by sliding in tracks, located at the front and rear of the hose bed.

Divider will be held in place by tightening bolts, at each end.

Acorn nuts will be installed on all bolts in the hose bed which have exposed threads. 0815195 Cover, Hose Bed, Alum Treadplate,
Bolted T-Bar

HOSE BED COVER
A two (2) section hose bed cover, constructed of .125" bright aluminum treadplate, will be furnished. The cover will be hinged with full length stainless steel piano hinge. The sides will be slanted down with the center of the cover supported by a stationary modular bridgework support.

The cover will be reinforced so that it can support the weight of a man walking on the cover.

The cover is designed with the left cover opening first.

If access to water tank fill tower is blocked by the hose bed cover, then a hinged door will be provided in it so that tank may be filled without raising cover doors.

Chrome grab handles and gas filled cylinders will be provided to assist in opening and closing the cover. A handrail is provided at the rear, in the center of the support, to assist in opening the cover.

The hose bed cover will be connected to the Do Not Move Truck indicator. The light will be activated if the cover is not in the stowed position and the parking brake is released. 0807414 Hose Restraint, Hose Bed, Vinyl,
Rear, Separate From Top, Split 2-
Sec, Seat Belt

HOSE RESTRAINT REAR
At the rear of the hose bed, a black vinyl flap will be provided. The vinyl flap will be split into two sections HB REAR. The vinyl flap will be provided with permanent strap footman loop at the bottom of the hose bed. The top of the vinyl flap will be attached to the top of the hosebed with seat belt buckles. The seat belt buckles will be provided with no tether release. The vinyl flap will be provided with hook and loop between each section. The bottom of the flap will be not weighted.

If a strap is provided, the color of the strap will be N/A. 0010133 Cross-Divider, Hose Bed

A cross-divider will be provided just behind the fill tower. The divider will be bolted to the side sheet.
0013512 Running Boards, 12.75" Deep

RUNNING BOARDS
Running boards will be fabricated of 0.125" bright aluminum treadplate.

Each running board will be supported by a welded 2.00" square tubing and channel assembly, which will be bolted to the pump compartment substructure.

Running boards will be 12.75" deep and spaced 0.50" away from the pump panel.

A splash guard will be provided above the running board treadplate. 0689621 Tailboard, 16" Deep TAILBOARD
The tailboard will also be constructed of .125" bright aluminum treadplate and spaced .50" from the body, as well as supported by a structural steel assembly.

The tailboard area will be 16.00" deep.

The exterior side will be flanged down and in for increased rigidity of tailboard structure. 0690037 Wall, Rear, Smooth Aluminum/Body
Material

REAR WALL, SMOOTH ALUMINUM/BODY MATERIAL
The rear facing surfaces of the center rear wall will be smooth aluminum.

The bulkheads, the surface to the rear of the side body compartments, will be smooth and the same material as the body.

Any inboard facing surfaces below the height of the hosebed will be aluminum diamondplate.

Bid #: 955 35 11.55
0889214 Tow Eyes, w/Tow Bar, 2G Pumper

REAR TOW EYES
Two (2) tow eyes, which are an integral part of the body mounting substructure, will be installed below the rear of the truck.

The tow eyes will be of adequate strength to allow the truck to be pulled from the eyes.

REAR TOW BAR
One (1) tow bar will be installed under the tailboard.

The tow bar assembly will be designed and positioned to allow up to a 30-degree upward angled pull of 17,000 lb, or a 20,000 lb straight horizontal pull in line with the centerline of the vehicle.

The tow bar design will have been tested and evaluated using finite element analysis techniques. 0590934 Hose Restraint, Running Board,
Straps, FV Fastener

RUNNING BOARD HOSE RESTRAINT
A pair of 2.00" wide black nylon straps with 2.00" side release fasteners will be provided for each hose tray to secure the hose during travel. There will be Two (2) hose trays located one (1) in each side running board.
0014112 Tray, Hose, Running Board, Special
Capacity, Predefined

HOSE TRAY
Two (2) hose trays will be recessed one (1) in each side running board.

Capacity of the tray will be 25' of 5.00" hose.

Rubber matting will be installed on the floor of the tray to provide proper ventilation. Drain holes will be provided.

Bid #: 955 36 11.56
0895820 Construction, Compt, Alum, 2G
Pumper

COMPARTMENTATION
Body and compartments will be fabricated of 0.125", 5052-H32 aluminum.

Side compartments will be an integral assembly with the rear fenders.

Circular fender liners will be provided for prevention of rust pockets and ease of maintenance.

Side compartment flooring will be of the sweep out design with the floor higher than the compartment door lip.

The side compartment door opening will be framed by flanging the edges in 1.75" and bending out again 0.75" to form an angle.

Drip protection will be provided above the doors by means of bright aluminum extrusion, formed bright aluminum treadplate or polished stainless steel.

The top of the compartment will be covered with bright aluminum treadplate rolled over the edges on the front, rear and outward side. These covers will have the corners welded.

Side compartment covers will be separate from the compartment tops.

Front facing compartment walls will be covered with bright aluminum treadplate.

All screws and bolts which protrude into a compartment will have acorn nuts on the ends to prevent injury.

UNDERBODY SUPPORT SYSTEM
Due to the severe loading requirements of this pumper a method of body and compartment support suitable for the intended load will be provided.

The backbone of the support system will be the chassis frame rails which is the strongest component of the chassis and is designed for sustaining maximum loads.

Forward to the rear axle, the support system will include "L"-shaped support members bolted to the chassis frame rails. These welded support members will include vertical formed channels, horizontal structural channels, and support gussets. These parts extend from the chassis frame outward underneath the body.

Rearward to the rear axle, the body support system will include two rearward facing "L"-shaped support members bolted to the chassis frame rails. These support members will be connected to the two body supporting crossmembers forming a boxed foundation for the rear body support system.

Steel upper platform decks will be mounted on the top of these support members to create a floating substructure which will result in a 500 lb equipment support rating per lower compartment.

All structural components of this system will be made from high strength 50K steel plate material or structural steel componentry. The steel frames as well as the steel vertical angles will be treated with an epoxy E-coat to provide resistance to corrosion and chemicals as standard.

The floating substructure will be separated from the horizontal members with neoprene elastomer isolators. These isolators will reduce the natural flex stress of the chassis from being transmitted to the body.

Isolators will have a broad load range, proven viability in vehicular applications, be of a fail-safe design and allow for all necessary movement in three (3) transitional and rotational modes.

The neoprene isolators will be installed in a pattern which assimilates a three (3)-point mounting pattern to reduce the natural flex of the chassis being transmitted to the body.

A design with body compartments hanging on the chassis in an unsupported fashion will not be acceptable.

AGGRESSIVE WALKING SURFACE
All exterior surfaces designated as stepping, standing, and walking areas will comply with the required average slip resistance of the current NFPA standards.

LOUVERS
Louvers will be stamped into compartment walls to provide the proper airflow inside the body compartments and to prevent water from dripping into the compartment. Where these louvers are provided, they will be formed into the metal and not added to the compartment as a separate plate.

TESTING OF BODY DESIGN
Body structural analysis will be fully tested. Proven engineering and test techniques such as finite element analysis, strain gauging, and model analysis will be performed with special attention given to fatigue, life and structural integrity of the body and substructure.

Body will be tested while loaded to its greatest in-service weight.

The criteria used during the testing procedure will include:

Raising opposite corners of the vehicle tires 9.00" to simulate the twisting a truck may experience when driving over a curb.

Making a 90 degree turn, while driving at 20 mph to simulate aggressive driving conditions.

Driving the vehicle at 35 mph on a washboard road.

Driving the vehicle at 55 mph on a smooth road.

Accelerating the vehicle fully, until reaching the approximate speed of 45 mph on rough pavement.

Evidence of actual testing techniques will be made available upon request.

Bid #: 955 37 11.57
0023650 LS 152" Rollup, Full Height Front &
Rear, FDLER

LEFT SIDE COMPARTMENTATION
The left side compartmentation will consist of three rollup door compartments.

A full height, rollup door compartment ahead of the rear wheels will be provided. The interior dimensions of this compartment will be 34.50" wide x 66.63" high x 25.88" deep in the lower

25.00" of the compartment and 12.00" deep in the remaining upper portion. The clear door opening will be a minimum of 28.75" wide x 56.88" high.

A rollup door compartment over the rear wheels will be provided. The interior dimensions of this compartment will be 66.50" wide x 32.88" high x 12.00" deep. The clear door opening will be a minimum of 58.25" wide x 23.13" high.

A full height, rollup door compartment behind the rear wheels will be provided.The interior dimensions of this compartment will be 47.75" wide x 67.63" high x 25.88" deep in the lower 26.00" of height and 12.00" deep in the remaining upper section of the compartment.

The clear door opening will be a minimum of 44.75" wide x 57.88" high.

The interior height of the compartments will be measured from the compartment floor to the ceiling. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartments will be measured from the back wall to the inside of the door frame.

Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.
0063658 RS 152" Rollup, Full Height Front &
Rear, FDLER

RIGHT SIDE COMPARTMENTATION
The right side compartmentation will consist of three rollup door compartments.

A full height, rollup door compartment ahead of the rear wheels will be provided. The interior dimensions of this compartment will be 34.50" wide x 66.63" high x 25.88" deep in the lower

25.00" of the compartment and 12.00" deep in the remaining upper portion. The clear door opening will be a minimum of 28.75" wide x 56.88" high.

A rollup door compartment over the rear wheels will be provided. The interior dimensions of this compartment will be 66.50" wide x 32.88" high x 12.00" deep. The clear door opening will be a minimum of 58.25" wide x 23.13" high.

A full height, rollup door compartment behind the rear wheels will be provided.The interior dimensions of this compartment will be 47.75" wide x 67.63" high x 25.88" deep in the lower 26.00" of height and 12.00" deep in the remaining upper section of the compartment.

The clear door opening will be a minimum of 44.75" wide x 57.88" high.

The interior height of the compartments will be measured from the compartment floor to the ceiling. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartments will be measured from the back wall to the inside of the door frame.

Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.
0594005 Doors, Rollup, Amdor, Side
Compartments

SIDE COMPARTMENT ROLLUP DOOR(S)
There will be six (6) compartment doors installed on the side compartments, double faced, aluminum construction, painted one (1) color to match the lower portion of the body and manufactured by AMDOR™ brand rollup doors.

Door(s) will be constructed using 1.00" extruded double wall aluminum slats which will feature a flat smooth interior surface to provide maximum protection against equipment hang-up. The slats will be connected with a structural driven ball and socket hinge designed to provide maximum curtain diaphragm strength. Mounting and adjusting the curtain will be done with a clip system that connects the curtain to the balancer drum allowing for easy tension adjustment without tools.

The slats will be mounted in reusable slat shoes with positive snap-lock securement.

Each slat will incorporate weather tight recessed dual durometer seals. One (1) fin will be designed to locate the seal within the extrusion. The second will serve as a wiping seal which will also allow for compression to prevent water ingression.

The doors will be mounted in a one (1)-piece aluminum side frame with recessed side seals to minimize seal damage during equipment deployment. All seals including side frames, top gutters and bottom panel are to be manufactured utilizing non-marring materials.

Bottom panel flange of rollup door will be equipped with two (2) cut-outs to allow for easier access with gloved hands.

A polished stainless steel lift bar with locking key latches to be provided for each roll-up door. The keys to be Model 751 to match all compartment and cab doors. The lift bar will be located at the bottom of door with striker latches installed at the base of the side frames. Side frame mounted door strikers will include support beneath the stainless steel lift bar to prevent door curtain bounce, improve bottom seal life expectancy and to avoid false door ajar signals.

All injection molded rollup door wear components will be constructed of Type 6 nylon.

Each rollup door will have a 3.00 inch diameter balancer/tensioner drum to assist in lifting the door.

The header for the rollup door assembly will not exceed 4.00".

A heavy-duty magnetic switch will be used for control of open compartment door warning lights. 0083701 Compt, Rear, Rollup, 44.50" FF,

25.88" D

REAR COMPARTMENTATION
A roll-up door compartment above the rear tailboard will be provided.

The interior dimensions of this compartment will be 40.00" wide x 47.38" high x 25.88" deep. The spool of the rollup door at the top of the compartment takes up some usable space. The depth of the compartment will be calculated with the compartment door closed.

A louvered, removable access panel will be furnished on the back wall of the compartment.

The rear compartment will be open into the rear side compartments.

The clear door opening of this compartment will be a minimum of 33.25" wide x 37.63" high.

Closing of the door will not require releasing, unlocking, or unlatching any mechanism and will easily be accomplished with one hand.

Bid #: 955 38 11.58
0594003 Door, Amdor, Rollup, Rear
Compartment

ROLLUP REAR COMPARTMENT DOOR
The rear compartment will have a rollup door.

The door will be double faced, aluminum construction, satin aluminum and manufactured by AMDOR™ brand rollup doors.

The door will be constructed using 1.00" extruded double wall aluminum slats which will feature a flat smooth interior surface to provide maximum protection against equipment hang-up. The slats will be connected with a structural driven ball and socket hinge designed to provide maximum curtain diaphragm strength. Mounting and adjusting the curtain will be done with a clip system that connects the curtain to the balancer drum allowing for easy tension adjustment without tools.

The slats will be mounted in reusable slat shoes with positive snap-lock securement.

Each slat will incorporate weather tight recessed dual durometer seals. One (1) fin will be designed to locate the seal within the extrusion. The second will serve as a wiping seal which will also allow for compression to prevent water ingression.

The door will be mounted in a one (1)-piece aluminum side frame with recessed side seals to minimize seal damage during equipment deployment. All seals including side frames, top gutters and bottom panel are to be manufactured utilizing non-marring materials.

Bottom panel flange of rollup door will be equipped with two (2) cut-outs to allow for easier access with gloved hands.

A polished stainless steel lift bar with locking key latches to be provided for each roll-up door. The keys to be Model 751 to match all compartment and cab doors. The lift bar will be located at the bottom of door with striker latches installed at the base of the side frames. Side frame mounted door strikers will include support beneath the stainless steel lift bar to prevent door curtain bounce, improve bottom seal life expectancy and to avoid false door ajar signals.

All injection molded rollup door wear components will be constructed of Type 6 Nylon.

The door will have a 3.00 inch diameter balancer/tensioner drum to assist in lifting the door.

The header for the rollup door assembly will not exceed 4.00".

A heavy-duty magnetic switch will be used for control of open compartment door warning lights. 0554995 No Body Modification Required

0632487 Guard, Switch, Rollup Door, Stainless
Steel

GUARD FOR DOOR SWITCH
There will be 16 gauge stainless steel guard(s) provided to protect the roll up door switch(s) from loose equipment inside the compartments. There will be one (1) compartment door located RS3 that include these guards.
0625184 Guard, Drip Pan, S/S, Rollup Door,
Pumper

DOOR GUARD
There will be seven (7) compartment doors that will include a guard/drip pan designed to protect the rollup door from damage when in the retracted position and contain any water spray. The guard will be fabricated from stainless steel and installed left side rearward compartment, left side over the wheel compartment, left side forward compartment, right side rearward compartment, right side over the wheel compartment, right side forward compartment and rear compartment. 0616670 Lights, Compt, Pierce LED, Dual
Light Strips, Each Side of Door,
Pumper/Tanker

COMPARTMENT LIGHTING
There will be seven (7) compartment(s) with two (2) white 12 volt DC LED compartment light strips. The dual light strips will be centered vertically along each side of the door framing. There will be two (2) light strips per compartment. The dual light strips will be in all body compartment (s).

Any remaining compartments without light strips will have a 6.00" diameter Truck-Lite, Model:
79384 light. Each light will have a number 1076 one filament, two wire bulb.

Opening the compartment door will automatically turn the compartment lighting on. 0761022 Lights, Cargo/Dunnage, Amdor AYLB-12HW020 Brkt CARGO/DUNNAGE AREA LIGHTING There will be one (1) Amdor®, Model AY-LB-12HW020, 20.00" 12 volt DC strip light(s) with white LEDs and 45 degree aluminum housing to illuminate the cargo area. The light(s) will be located, rear wall centered.

The light will be activated when the battery switch is on and the body step lights are activated. 0687146 Shelf Tracks, Painted

MOUNTING TRACKS
There will be six (6) sets of tracks for mounting shelf(s) in LS1, LS2, LS3, RS1, RS3 and B1.

These tracks will be installed vertically to support the adjustable shelf(s). The tracks will be painted to match the compartment interior.
0600350 Shelves, Adj, 500 lb Capacity, Full
Width/Depth, Predefined Locations

ADJUSTABLE SHELVES
There will be nine (9) shelves with a capacity of 500 lb provided.

The shelf construction will consist of .188" aluminum painted spatter gray with 2.00" sides.

Each shelf will be infinitely adjustable by means of a threaded fastener, which slides in a track.

The shelves will be held in place by .12" thick stamped plated brackets and bolts.

The location(s) will be in LS1 at the depth transition point, in RS1 at the transition point, in RS3 at the transition point to the right of partition, in RS3 in the upper third to the right of the partition, in LS2 centered between the floor and ceiling, in LS3 centered between the floor and ceiling, in B1 in the lower third, in LS1 in the upper third and in B1 in the upper third.

Bid #: 955 39 11.59
0647091 Tray, Floor Mounted, Slide-Out,
500lb, 2.00" Sides

SLIDE-OUT FLOOR MOUNTED TRAY
There will be two (2) floor mounted slide-out tray(s) provided.

Each tray will have 2.00" high sides and a minimum capacity rating of 500 lb in the extended position.

Each tray will be constructed of aluminum painted spatter gray.

There will be two undermount-roller bearing type slides rated at 250 lb each provided. The pair of slides will have a safety factor rating of 2.

To ensure years of dependable service, the slides will be coated with a finish that is tested to withstand a minimum of 1,000 hours of salt spray per ASTM B117.

To ensure years of easy operation, the slides will require no more than a 50lb force for push-in or pull-out movement when fully loaded after having been subjected to a 40 hour vibration (shaker) test under full load. The vibration drive file will have been generated from accelerometer data collected from a heavy truck chassis driven over rough gravel roads in an unloaded condition.

Proof of compliance will be provided upon request.

Automatic locks will be provided for both the "in" and "out" positions. The trip mechanism for the locks will be located at the front of the tray for ease of use with a gloved hand.

The location(s) will be RS1 and LS1.
0725642 Cabinet, Drawer Assembly, CTECH,
Three Drawers, Up To 36" Wide, 24"
Deep

DRAWER ASSEMBLY
A slide-out drawer assembly will be installed LS3.

The clear dimensions of the first drawer starting at the top will be 3.00" with a face plate that is

4.00" high x 21.00" deep. The clear dimensions of the second drawer will be 7.75" with a face plate that is 8.00" high x 21.00" deep. The clear dimensions of the third drawer will be 7.75" with a face plate that is 8.00" high x 21.00" deep. Each drawer will be the same width and not exceed

36.00".

The drawers will have a capacity of 250 pounds.

The drawers will be mounted in a cabinet housing constructed of light gray powder coated aluminum with anodized aluminum frames. The housing will be 24.00" deep, and completely enclose the drawer.

A full-length aluminum extruded rail will be provided at the top edge of each drawer. This rail will act as the latching mechanism as well as the handle for each drawer.

There will be a total of one (1) provided.
0726441 Partition, Trans Rear Compt PARTITION, TRANSVERSE REAR COMPARTMENT Two (2) partitions will be bolted in place to separate the left and right side rear compartments from the rear tailboard compartment. The partition will be body material painted spatter gray. 0726403 Partition, Vertical Compt, Special
Height

VERTICAL COMPARTMENT PARTITION
One (1) partition will be bolted in from the transition to the top . Each partition will be RS3 12" from the forward door frame vertical height of the compartment. Each partition will be painted spatter gray.
0502687 Matting, Dri-Deck, Compartment
Trays and Shelves

MATTING, COMPARTMENT TRAYS AND SHELVES
Dri-Deck rubber compartment matting will be provided in the compartments on 11 compartment trays and shelves. The compartment trays and shelves locations will be: all compartments.

The Dri-Deck will be black, and .562" thick with holes in the decking to allow air to flow. 0006118 Matting, Dri-Deck w/Bevel,
Compartment Floor only

MATTING, COMPARTMENT FLOOR
Dri-Deck rubber compartment matting will be provided in four (4) compartments on the compartment floor. The locations are, LS2, RS 2 RS3, B1.

The Dri-Deck will be black and .562" thick with holes in the decking to allow air to flow. The leading edge of the matting will include the beveled edge. 0755538 Toolboard, Back Wall Mounted, 3/16"
Alum, Full Height Compt

TOOLBOARD
There will be 3/16" thick aluminum toolboard (no holes) spatter gray painted installed on the back wall of two (2) compartment(s). The toolboard will be mounted using two (2) horizontal tracks.

Retainers will be used to mount the toolboard to the tracks. The toolboard will be installed the full height of the back wall. Toolboard will be installed in the following compartment(s): RS1 and RS2. 0755528 Toolboard, Alum, .188", No Holes,
Back Wall Mounted, Special

TOOLBOARD
There will be 3/16" thick aluminum toolboard (no holes) spatter gray painted installed on the back wall of two (2) compartment(s). The toolboard will be mounted using two (2) horizontal tracks.

Retainers will be used to mount the toolboard to the tracks. The toolboard will be located in the LS3 and RS3 and mounted RS3 BACK WALL REAR OF THE VERTICAL PARTITION AND LS3 BACK WALL ABOVE THE SHELF.
0024016 Rub Rail, Aluminum Extruded, Side &
Rear of Body

RUB RAIL
Bottom edge of the side and rear of the body compartments will be trimmed with a bright aluminum extruded rub rail.

Trim will be 2.12" high with 1.38" flanges turned outward for rigidity.

The rub rails will not be an integral part of the body construction, which allows replacement in the event of damage.

Bid #: 955 40 11.60
0784811 Fender Crowns, Rear, Stainless,
w/Removable Liner

BODY FENDER CROWNS
Polished stainless steel fender crowns will be provided around the rear wheel openings with a dielectric barrier will be provided between the fender crown and the fender sheet metal to prevent corrosion.

The fender crowns will be held in place with stainless steel screws that thread directly into a composite nut and not directly into the parent body sheet metal to eliminate dissimilar metals contact and greatly reduce the chance for corrosion. Rubber welting will be provided between the body and crown.

BODY FENDER LINER
A painted to match the lower body color fender liner will be provided. The liners will be removable to aid in the maintenance of rear suspension components. 0816944 Hose, Hard Suction, Provided by Fire
Department, NFPA 2024

HARD SUCTION HOSE
Hose is not on the apparatus as manufactured. The fire department will provide suction or supply hose.

There will be Two (2) lengths of 10' long x 3.00" diameter hose provided and equipped with long handle couplings provided on the ends.
0035476 Troughs, HSH, LS, Aluminum, Double HOSE TROUGHS Troughs for hard suction hose will be provided on top of the left side body compartments.

Troughs will be V-shaped and located side by side. The hose will be held in place by chrome plated, quarter turn, spring loaded clamps.

Troughs will be constructed of aluminum and painted job color. 0626229 Handrails, Side Pump Panels, Per
Print

HANDRAILS
The handrails will be 1.25" diameter knurled aluminum to provide a positive gripping surface.

Chrome plated end stanchions will support the handrail. Plastic gaskets will be used between end stanchions and any painted surfaces.

Drain holes will be provided in the bottom of all vertically mounted handrails.

Handrails will be provided to meet current edition of applicable NFPA standards. The handrails will be installed as noted on the sales drawing.
0025450 Handrails, Rear Bulkhead

One (1) vertical handrail will be located on each rear bulkhead. 0030332 Handrails, Rear, (2) Below Hose Bed,
One Each Side
Two (2) horizontal knurled aluminum handrails will be provided below the hose bed at the rear of the apparatus, one each side.
0004154 Handrail, Extra - 10" Long

ADDITIONAL HANDRAIL
Two (2) handrails, 10.00" long, will be mounted TOP FRONT OF THE HOSEBED SHEET PER THE AD. The handrail will be constructed out of knurled aluminum. 0519354 Handrail, Extra - 12"

ADDITIONAL HANDRAIL
One (1) handrail, 12.00" long, will be mounted DS vertical upright of rear hose bed per AD. The handrail(s) will be constructed out of knurled aluminum. 0622393 Compt, Air Pack Fender Panel AIR PACK STORAGE
A total of two (2) air pack compartment(s) will be provided and located on the left side forward of the rear wheels and on the right side forward of the rear wheels. The air pack compartment(s) will be tapered to match the profile of the space available in the fender. The compartment(s) will be approximately 15.50" wide at the top and 5.00" wide at the bottom for the wheel cutout. The compartment(s) will be 15.50" tall at the body side compartment and 6.00" tall at the wheel cutout. The compartment(s) will be 26.00" deep and have a drain hole.

Inside the compartment, black Dura-Surf friction reducing material will be provided.

A polished stainless steel hinged door with a chrome plated flush lift & turn latch will be provided to contain the air pack. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body sheet metal.
0654143 Compt, Air Bottle, Single,Tri Door
(DEF/Fuel), Fender Panel
AIR BOTTLE STORAGE (Single)
A quantity of one air bottle compartment, approximately 7.50" wide x 7.50" tall x 26.00" deep, will be provided on the driver side rearward of the rear wheels. The triangular door will cover the air bottle opening, the DEF tank access, and fuel fill. The compartment will be square with angled corners. A polished stainless steel door with a chrome plated flush lift & turn latch will be provided to contain the air bottle. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body sheet metal.

Inside the compartment, black Dura-Surf friction reducing material will be provided.

AIR BOTTLE COMPARTMENT STRAP
A strap will be provided in the air bottle compartment to help contain the air bottle when the vehicle is parked on an incline. The strap will wrap around the neck and attach to the wall of the compartment.

Bid #: 955 41 11.61
0657522 Compt, Air Bottle, Triple, Fender
Panel
AIR BOTTLE STORAGE (Triple)
A quantity of one (1) air bottle compartment designed to hold (3) air bottles up to 7.25" in diameter x 26.00" deep will be provided on the right side rearward of the rear wheels. A polished stainless steel door with a chrome plated flush lift & turn latch will be provided to contain the air bottle. A dielectric barrier will be provided between the door hinge, hinge fasteners and the body sheet metal.

Inside the compartment, black Dura-Surf friction reducing material will be provided.

AIR BOTTLE COMPARTMENT STRAP
A strap will be provided in the air bottle compartment(s) to help contain the air bottles when the vehicle is parked on an incline. The strap will wrap around the neck and attach to the wall of the compartment.
0004225 Ladder, 24' Duo-Safety 900A 2-
Section

EXTENSION LADDER
There will be a 24' two-section aluminum Duo-Safety Series 900-A extension ladder provided. 0004230 Ladder, 14' Duo-Safety 775A Roof ROOF LADDER
There will be a 14' aluminum Duo-Safety Series 775-A roof ladder provided. 0787027 Ladders Btwn Tank & S.Sht, RS,
Extended Rear, Enclosed, RPH,
Special Mounting

LADDER STORAGE
The ladders will be stored between the water tank and the right side compartments.

The ladders will extend into the pump compartment just to the rear of the water pump discharges.

The ladder storage area will be enclosed as practical by means of sheet metal to protect the ladders from road dirt. The ladders that extend into the pump house will also be enclosed. A black rubber boot will be provided to enclosed the ladders in the gap between the pump house and the body.

Each ladder will be stored vertically in a separate stainless steel storage trough. Each stainless steel trough will be lined with Dura-Surf nylon slides.

If the apparatus does not have a flush rear wall, an aluminum enclosure will be provided at the rear of the body to properly contain the ladders. This enclosure will extend to the rear of the side body compartments.

The ladders will be stored fly section inboard.

The enclosure will also include a vertically hinged smooth aluminum door with a D-handle latch to access the ladders.
0733387 Ladder, 10' Duo-Safety Folding 585A

FOLDING LADDER
One (1) 10.00' aluminum, Series 585-A, Duo-Safety folding ladder will be installed. 0733796 Trough, Folding Ladder, Ladder
Storage Btwn Tank & S.Sht

FOLDING LADDER STORAGE
There will be storage designated right side for folding ladders stored between the side sheet in a stainless steel trough in the ladder storage compartment. 0892606 SP Compt w/Door, Stokes Basket
Storage, Top of 4-Way Hose Bed
Cover, Liftup Door

STOKES BASKET COMPARTMENT
A stokes basket compartment will be mounted to the top of the bright aluminum treadplate hose bed cover on the left side. The compartment will be fabricated of bright aluminum treadplate and will have a bright aluminum treadplate lift-up door at the rear. The compartment(s) will be sized for a stokes basket 84.00" long x 25.00" wide x 9.00" high. 0816920 Pike Pole, Provided by Fire
Department, NFPA 2024

PIKE POLE PROVIDED BY FIRE DEPARTMENT
The pike poles are not on the apparatus as manufactured. The fire department will provide and mount the pike poles.

There will be one (1) pike pole(s) provided. The pike pole(s) will be a Duo-Safety 10' pike pole. 0760175 Tube, Pike Pole 8' or Longer, Btwn
Tank & S.Sht Ladder Storage

PIKE POLE STORAGE
There will be storage designated on the right side for One (1) pike pole 8' or longer pike poles with a .75" standard notch, stored in a tube between the side sheet and tank in the ground ladder storage compartment.
0816918 Pike Pole, 6', Provided by Fire
Department, NFPA 2024
6' PIKE POLE PROVIDED BY FIRE DEPARTMENT
The pike pole is not on the apparatus as manufactured. The fire department will provide and mount the pike poles.

There will be one (1) 6' pike pole(s) provided. The pike pole(s) will be a Duo-Safety 6' pike pole. 0760247 Tube, Pike Pole 6', Btwn Tank &
S.Sht Ladder Storage

PIKE POLE STORAGE
There will be storage designated right side for One (1) pike pole with a .75" standard notch stored in a tube between the side sheet and tank in the ground ladder storage compartment.

Bid #: 955 42 11.62
0785102 Steps, Folding, Front of Body, Cargo
Bed Access, w/LED, Trident

FOLDING STEPS FRONT OF BODY
Folding steps will be provided full height on the left side and right side body compartments to provide access to the cargo bed. Steps will be spaced evenly on the sales drawing. Actual quantity may vary due to pump panel interferences but will meet the NFPA required maximum stepping height.

The Trident steps will be bright finished, non-skid with a black tread coating on the stepping surface.

The step will incorporate an LED light to illuminate the stepping surface.

The steps can be used as a hand hold with two openings wide enough for a gloved hand. 0592995 Steps, Combo Folding Trident w/LED
& Corner, Rear Body

REAR STEPS
Aluminum treadplate corner steps and bright finished, non-skid folding steps will be provided at the rear. The folding steps will have a a black tread coating. Each folding step will incorporate an LED light to illuminate the stepping surface. The folding steps can be used as a hand hold with two openings wide enough for a gloved hand. All steps will provide adequate surface for stepping. 0650261 I Zone Bracket, Pair, Folding Style

I-ZONE BRACKETS
Two (2) flip-out I-Zone brackets will be provided and mounted at the rear of the apparatus, as shown on AD. The brackets will be designed with adequate reinforcement to eliminate flexing of the body (oil canning).
0019940 Step, Special Width, Rear Of Body,

8.00"
An 8.00" deep bright aluminum treadplate step will be provided at the rear of the body above the rear compartment.
0007575 Pump House, Side Control, 48",
Control Zone

PUMP COMPARTMENT
The pump compartment will be separate from the hose body and compartments so that each may flex independently of the other. The pump compartment will be constructed of the same material as the body compartmentation.

The pump compartment substructure will be a fabricated assembly of steel tubing, angles and channels which supports both the fire pump and the side running boards.

The pump compartment will be mounted on the chassis frame rails with rubber biscuits in a four point pattern to allow for chassis frame twist.

Pump compartment, pump, plumbing and gauge panels will be removable from the chassis in a single assembly.

PUMP MOUNTING
Pump will be mounted to a substructure which will be mounted to the chassis frame rail using rubber isolators. The mounting will allow chassis frame rails to flex independently without damage to the fire pump.

LEFT SIDE PUMP CONTROL PANEL
All pump controls and gauges will be located at the left (driver's) side of the apparatus and properly identified.

Layout of the pump control panel will be ergonomically efficient and systematically organized.

The pump operator's control panel will be removable in two (2) main sections for ease of maintenance:

The upper section will contain sub panels for the mounting of the pump pressure control device, engine monitoring gauges, electrical switches, and foam controls (if applicable). Sub panels will be removable from the face of the pump panel for ease of maintenance. Below the sub panels will be located all valve controls and line pressure gauges.

The lower section of the panel will contain all inlets, outlets, and drains.

All push/pull valve controls will have 1/4 turn locking control rods with polished chrome plated zinc tee handles. Guides for the push/pull control rods will be chrome plated zinc castings securely mounted to the pump panel. Push/pull valve controls will be capable of locking in any position.

The control rods will pull straight out of the panel and will be equipped with universal joints to eliminate binding.

IDENTIFICATION TAGS
The identification tag for each valve control will be recessed in the face of the tee handle.

All discharge outlets will have color coded identification tags, with each discharge having its own unique color. Color coding will include the labeling of the outlet and the drain for each corresponding discharge.

All line pressure gauges will be mounted directly above the corresponding discharge control tee handles and recessed within the same chrome plated casting as the rod guide for quick identification. The gauge and rod guide casting will be removable from the face of the pump panel for ease of maintenance. The casting will be color coded to correspond with the discharge identification tag.

All remaining identification tags will be mounted on the pump panel in chrome plated bezels.

The pump panel on the right (passenger's) side will be removable with lift and turn type fasteners.

Trim rings will be installed around all inlets and outlets. 0037731 Pump House Structure, Raised,
Included with Ladder Storage

0679683 Bracket, Monitor Tip Support,
Connected to Do Not Move Truck

A bracket will be provided to support the monitor tip. The bracket will be fabricated of steel and painted to match the apparatus.

The bracket will be wired to the "Do not move apparatus" light in the cab to indicate if the monitor tip is not in the stowed position when the parking brake is released.

Bid #: 955 43 11.63
0004415 Pump, Waterous, CS, 1250 GPM,
Single Stage
PUMP
Pump will be a Waterous CS, 1250 gpm, single (1) stage midship mounted centrifugal type.

Pump will be the class "A" type.

Pump will deliver the percentage of rated discharge at pressures indicated below:
- 100% of rated capacity at 150 psi net pump pressure.
- 70% of rated capacity at 200 psi net pump pressure.
- 50% of rated capacity at 250 psi net pump pressure.

Pump body will be close-grained gray iron, bronze fitted, and horizontally split in two (2) sections for easy removal of the entire impeller shaft assembly (including wear rings).

Pump will be designed for complete servicing from the bottom of the truck, without disturbing the pump setting or apparatus piping.

Pump case halves will be bolted together on a single horizontal face to minimize a chance of leakage and facilitate ease of reassembly. No end flanges will be used.

Discharge manifold of the pump will be cast as an integral part of the pump body assembly and will provide a minimum of three (3) 3.50" openings for flexibility in providing various discharge outlets for maximum efficiency.

The three (3) 3.50" openings will be located as follows: one (1) outlet to the right of the pump, one (1) outlet to the left of the pump, and one (1) outlet directly on top of the discharge manifold.

Impeller shaft will be stainless steel, accurately ground to size. It will be supported at each end by sealed, anti-friction ball bearings for rigid precise support.

Bearings will be protected from water and sediment by suitable stuffing boxes, flinger rings, and oil seals. No special or sleeve type bearings will be used. 0004482 Seal, Mechanical, Waterous

Pump will be equipped with a self-adjusting, maintenance-free, mechanical shaft seal.

The mechanical seal will consist of a flat, highly polished, spring fed carbon ring that rotates with the impeller shaft. The carbon ring will press against a highly polished stainless steel stationary ring that is sealed within the pump body.

In addition, a throttling ring will be pressed into the steel chamber cover, providing a very small clearance around the rotating shaft in the event of a mechanical seal failure. The pump performance will not deteriorate, nor will the pump lose prime, while drafting if the seal fails during pump operation.

Wear rings will be bronze and easily replaceable to restore original pump efficiency and eliminate the need to replace the entire pump casing due to wear. 0816447 Trans, Pump, Waterous C22 Series PUMP TRANSMISSION The pump transmission will be made of a three (3) piece, aluminum, horizontally split casing.

Power transfer to pump will be through a high strength Morse HY-VO silent drive chain. By the use of a chain rather than gears, 50% of the sprocket will be accepting or transmitting torque, compared to two (2) or three (3) teeth doing all the work.

Drive shafts will be 2.35" diameter hardened and ground alloy steel and supported by ball bearings. The case will be designed to eliminate the need for water cooling. 0635600 Pumping Mode, Stationary Only

PUMPING MODE
An interlock system will be provided to ensure that the pump drive system components are properly engaged so that the apparatus can be safely operated. The interlock system will be designed to allow stationary pumping only.
0605126 Pump Shift, Air Mnl Override, Split
Shaft, Interlocked, Waterous

AIR PUMP SHIFT
Pump shift engagement will be made by a two (2) position sliding collar, actuated pneumatically (by air pressure), with a three (3) position air control switch located in the cab. A manual back-up shift control will also be located on the left side pump panel.

Two (2) indicator lights will be provided adjacent to the pump shift inside the cab. One (1) green light will indicate the pump shift has been completed and be labeled "pump engaged". The second green light will indicate when the pump has been engaged, and that the chassis transmission is in pump gear. This indicator light will be labeled "OK to pump".

The pump shift will be interlocked to prevent the pump from being shifted out of gear when the chassis transmission is in gear to meet NFPA requirements.

The pump shift control in the cab will be illuminated to meet NFPA requirements. 0003148 Transmission Lock-up, EVS TRANSMISSION LOCK-UP
The direct gear transmission lock-up for the fire pump operation will engage automatically when the pump shift control in the cab is activated.
0004547 Auxiliary Cooling System

AUXILIARY COOLING SYSTEM
A supplementary heat exchange cooling system will be provided to allow the use of water from the discharge side of the pump for cooling the engine water. The heat exchanger will be a separate unit. It will be installed in the pump or engine compartment with the control located on the pump operator's control panel. The exchanger will be plumbed to the master drain valve. 0014486 Not Required, Transfer Valve, Single
Stage Pump
Bid #: 955 44 11.64
0746501 Valve, Relief Intake, Elkhart INTAKE RELIEF VALVE - PUMP There will be One (1) Elkhart Style 40 relief valve(s) installed on the suction side of the pump preset at 150 psig.

The relief valve(s) will have a working range of 75 psi to 250 psi.

The outlet will terminate below the frame rails with a 2.50" National Standard hose thread adapter and will have a "do not cap" warning tag.

The relief valve pressure control will be located behind the right side pump panel with a stainless steel access door.
0721609 Controller, Pressure, Pierce LCD,
Custom Chassis

PIERCE PRESSURE CONTROLLER
A Pierce electronic pressure controller will be provided.

A pressure transducer will be installed in the discharge side of the water pump. The transducer continuously monitors pump pressure sending a signal to the electronic pressure controller.

The pressure controller can be used in two (2) modes of operation, RPM mode and pressure modes. The controller will be programmed to turn on/default to Pressure Setting mode.

In the RPM mode, the controller can be activated after vehicle parking brake has been set. When in this mode, the controller will maintain the set engine speed, regardless of engine load (within engine operation capabilities).

In the pressure mode, the controller can be activated after vehicle parking brake has been set.

When in this mode, the controller will automatically maintain the discharge pressure set by the operator (within the discharge capabilities of the pump and water supply) regardless of flow.

A 2.00" diameter throttle control knob with no mechanical stops, a serrated grip, and a red idle push button in the center will be a integrated/part of the pressure controller. The throttle control knob will be programmed for Clockwise rotation to increase engine speed.

Individual LED indicators for ok to pump, throttle ready, pressure mode and rpm mode will be located on the pressure controller for easy viewing.

A pump cavitation protection feature will also be provided which will return the engine to idle should the pump cavitate. Cavitation is sensed by the combination of pump pressure below 30 psi and engine speed above 2000 rpm for more than five (5) seconds.

Other safety features include recognition of low water and no water conditions with an automatic programmed response and a push button to return the engine to idle.

The pressure controller LCD screen will be 4.20" in size with a minimum brightness of 750 nits.

The LCD screen and LED intensity will be automatically adjust for day and nighttime operation.

The LCD screen intensity can also be manually adjusted if needed.

The following information will be provided/displayed on the LCD screen - Engine RPM
Check engine and stop engine warning indicators
Engine oil pressure
Engine coolant temperature
Water pump transmission temperature
Fuel Level
Water tank level
Battery voltage
Operating mode (RPM or pressure)
Pressure or RPM setting
On screen messaging show diagnostic and warning messages as they occur. It will show apparatus information, stored data, and program options when selected by the operator. It will monitor inputs outputs and support audible and visual warning alarms for the following conditions -
High battery voltage
Low battery voltage/engine off
Low battery voltage/engine running
High water pump temperature
Low fuel
Low engine oil pressure
High engine coolant temperature
Water tank out of water (visual alarm only)
No engine response (visual alarm only)
The pressure controller will store the accumulated operating hours for the pump and engine.

These items are to be displayed within the pressure controller menu.

The pressure controller will include a USB port on the back of the controller for easy software upgrades if needed.
0024543 Primer, Hale, ESP Motor, (1) PVG
Valve, (1) T-Handle Control, For An
Other Pump

ESP PRIMING PUMP
Priming pump will be a positive displacement vane type, electrically driven, and conforming to the current edition of applicable NFPA standards.

One (1) priming control will open the priming valve and start the priming motor.

Primer will be environmentally safe and self lubricating. 0044552 Line, 0.50" Recirculating w/Check
Valve

RECIRCULATING LINE WITH CHECK VALVE
A 0.50" diameter recirculating line, from the pump to the water tank, will be furnished with a control installed at the pump operator's control panel. A check valve will be provided in this line to prevent the back flow of water from the tank to the pump if the valve is left in the open position. 0780364 Manuals, Pump, (2) Total, Electronic
Copies

PUMP MANUALS
There will be a total of two (2) pump manuals provided by the pump manufacturer and furnished with the apparatus. The manuals will be provided by the pump manufacturer in the form of two (2) electronic copies. Each manual will cover pump operation, maintenance, and parts.

Bid #: 955 45 11.65
0602512 Plumbing, Stainless Steel and Hose,
Single Stage Pump, Control Zone

PLUMBING, STAINLESS STEEL AND HOSE
All inlet and outlet lines will be plumbed with either stainless steel pipe, flexible polypropylene tubing or synthetic rubber hose reinforced with hi-tensile polyester braid. All hose's will be equipped with brass or stainless steel couplings. All stainless steel hard plumbing will be a minimum of a schedule 10 wall thickness.

Where vibration or chassis flexing may damage or loosen piping or where a coupling is required for servicing, the piping will be equipped with victaulic or rubber couplings.

Plumbing manifold bodies will be ductile cast iron or stainless steel.

All piping lines are to be drained through a master drain valve or will be equipped with individual drain valves. All drain lines will be extended with a hose to drain below the chassis frame.

All water carrying gauge lines will be of flexible polypropylene tubing.

All piping, hose and fittings will have a minimum of a 500 PSI hydrodynamic pressure rating. 0795135 Plumbing, Stainless Steel, w/Foam
System

FOAM SYSTEM PLUMBING
All piping that is in contact with the foam concentrate or foam/water solution will be stainless steel. The fittings will be stainless steel or brass. Cast iron pump manifolds will be allowed. 0004645 Inlets, 6.00" - 1250 GPM or Larger
Pump

MAIN PUMP INLETS
A 6.00" pump manifold inlet will be provided on each side of the vehicle. The suction inlets will include removable die cast zinc screens that are designed to provide cathodic protection for the pump, thus reducing corrosion in the pump.
0014650 Pump Suction Tube(s), Short, All

SHORT SUCTION TUBE(S)
The suction tube(s) on the water pump will have short suction tube(s) installed to allow for installation of adapters, elbows or intake valves without excessive overhang. 0730368 Valve, Ball Intake, TFT, AX Series INLET VALVES WITH INTAKE RELIEF VALVE There will be Two (2) Task Force Tips (TFT) AX Series aluminum ball intake valve(s) provided at EACH INLET .

The inlet connection will be 1SP (4.0" Rigid Storz) with a cap with a matching cap and the outlet connection will be NX (6.0" Threaded Swivel) . There will be an eight-position adjustable 30 degree swiveling detent elbow on the inlet side of the ball intake valve.

The ball intake valve will be controlled with a(n) standard crank on the left side .

If ball intake valve is to be controlled with a manual handwheel, the handwheel will be controlled with a NFPA compliant slow-close hand wheel. A position indicator will be provided to allow for a quick visualization of the status of the valve in the open, closed or transition position.

If the ball intake valve is to be electrically controlled, the ball intake valve will be controlled by a remote panel-mounted push-button switch with LED lights for a quick visualization of the status of the valve in the open, closed or transition position. The push button switch will be mounted on the pump operator's panel.

The ball intake valve will be equipped with a standard adjustable pressure relief valve. The relief valve will have a working range of 90 PSI to 300 PSI.

A 3/4" TFT bleeder/drain valve will be provided on the ball intake valve to exhaust excess air or water from the valve.

For corrosion protection the aluminum casting will have a hard coat anodized finish, with a powder coated internal and external finish. All the components facing the wet side of the valve will be constructed from stainless steel.
0004646 Cap, Main Pump Inlet, Long Handle,

NST, VLH

MAIN PUMP INLET CAP
The main pump inlets will have National Standard Threads with a long handle chrome cap.

The cap will be the Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0084610 Valves, Akron 8000 series- All

VALVES
All ball valves will be Akron® Brass. The Akron valves will be the 8000 series heavy-duty style with a stainless steel ball and a simple two-seat design. No lubrication or regular maintenance is required on the valve.

Valves will have a ten (10) year warranty.
0016158 Valve, Inlet(s) Recessed, Side Cntrl,
"Control Zone"
The location of the valve for the two (2) inlets will be recessed behind the pump panel. 0004700 Control, Inlet, at Valve

INLET CONTROL
The side auxiliary inlet(s) will incorporate a quarter-turn ball valve with the control located at the inlet valve. The valve operating mechanism will indicate the position of the valve. 0004660 Inlet (1), Left Side, 2.50"

LEFT SIDE INLET
There will be one (1) auxiliary inlet with a 2.50" valve at the left side pump panel, terminating with a 2.50" (F) National Standard hose thread adapter.

The auxiliary inlet will be provided with a strainer, chrome swivel and plug.

Bid #: 955 46 11.66
0004680 Inlet, Right Side, 2.50"

RIGHT SIDE INLET
There will be one (1) auxiliary inlet with a 2.50" valve at the right side pump panel, terminating with a 2.50" (F) National Standard hose thread adapter.

The auxiliary inlet will be provided with a strainer, chrome swivel and plug. 0034720 Anode, Zinc, Pair, Pump Inlets

ANODE, INLET
A pair of sacrificial zinc anodes will be provided in the water pump inlets to protect the pump from corrosion.
0092569 No Rear Inlet (Large Dia) Requested

0064116 No Rear Inlet Actuation Required

0092696 Not Required, Cap, Rear Inlet

0009648 No Rear Intake Relief Valve Required
on Rear Inlet
0092568 No Rear Auxiliary Inlet Requested

0723049 Valve, .75" Bleeder, Aux. Side Inlet,
"T" Swing Handle

INLET BLEEDER VALVE
A 0.75" bleeder valve will be provided for each side gated inlet.

The valves will be located behind the panel with a "T" swing style handle control extended to the outside of the panel.

The handles will be chrome plated and provide a visual indication of valve position. The swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage.

The water discharged by the bleeders will be routed below the chassis frame rails. 0014751 Tank to Pump, (1) 3.00" Valve, 3.00"
Plumbing, Reverse Linkage

TANK TO PUMP
The booster tank will be connected to the intake side of the pump with heavy duty piping and a quarter turn 3.00" full flow line valve with the control remotely located at the operator's panel. The tank to pump line will run straight (no elbows) from the pump into the front face of the water tank and down into the tank sump. A rubber coupling will be included in this line to prevent damage from vibration or chassis flexing.

The control on the pump panel will be "in" when the valve is open and "out" when the valve is closed.

A check valve will be provided in the tank to pump supply line to prevent the possibility of "back filling" the water tank.
0004905 Outlet, Tank Fill, 1.50"

TANK REFILL
A 1.50" combination tank refill and pump re-circulation line will be provided, using a quarter-turn full flow ball valve controlled from the pump operator's panel. 0062133 Control, Outlets, Manual, Pierce HW
if applicable

DISCHARGE OUTLET CONTROLS
The discharge outlets will incorporate a quarter-turn ball valve with the control located at the pump operator's panel. The valve operating mechanism will indicate the position of the valve.

If a handwheel control valve is used, the control will be a minimum of a 3.9" diameter stainless steel handwheel with a dial position indicator built in to the center of the handwheel.

Any 3.00 inch or larger discharge valve will be a slow-operating valve in accordance with NFPA

16.7.5.3. 0004940 Outlet, Left Side, 2.50"

LEFT SIDE DISCHARGE OUTLETS
There will be Two (2) discharge outlets with a 2.50" valve on the left side of the apparatus, terminating with a 2.50" (M) National Standard hose thread adapter. 0005091 Elbow, Left Side Outlets, 45 Degree,

2.50" FNST x 2.50" MNST, VLH

LEFT SIDE OUTLET ELBOWS
The 2.50" discharge outlets located on the left side pump panel will be furnished with a 2.50" (F) National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45 degree elbow.

The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0092570 Not Required, Outlets, Left Side
Additional
Bid #: 955 47 11.67
0035094 Not Required, Elbow, Left Side
Outlets, Additional
0004945 Outlet, Right Side, 2.50"

RIGHT SIDE DISCHARGE OUTLETS
There will be One (1) discharge outlet with a 2.50" valve on the right side of the apparatus, terminating with a 2.50" (M) National Standard hose thread adapter. 0025091 Elbow, Right Side Outlets, 45
Degree, 2.50" FNST x 2.50" MNST,
VLH

RIGHT SIDE OUTLET ELBOWS
The 2.50" discharge outlets located on the right side pump panel will be furnished with a 2.50" (F) National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45 degree elbow.

The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0092571 Not Required, Outlets, Right Side
Additional
0089584 Not Required, Elbow, Right Side
Outlets, Additional
0816625 Outlet, Large Diameter, Right Side,
Akron Valve

LARGE DIAMETER DISCHARGE OUTLET
There will be an Akron 8800 4.00" flat ball valve with 4.00" plumbing terminating with a 4.00" MNST chrome adapter on the right side pump panel.

The valve will be controlled with a(n) Pierce small handwheel with indicator located at the pump operator's panel.
0035197 Elbow, Large Dia Outlet, 30 Deg,

3.00" FNST x 4.00" Storz

LARGE DIAMETER OUTLET ELBOWS
The 3.00" outlet will be furnished with a 3.00" (F) National Standard hose thread x 4.00" Storz elbow adapter with Storz cap.
0649939 Outlet, Front, 1.50" w/2" Plumbing FRONT DISCHARGE OUTLET There will be one (1) 1.50" discharge outlet piped to the front of the apparatus and located on the top of the left side of the front bumper.

Plumbing will consist of 2.00" piping and flexible hose with a 2.00" ball valve with control at the pump operator's panel. A fabricated weldment made of stainless steel pipe will be used in the plumbing where appropriate. The piping will terminate with a 1.50" NST with 90 degree stainless steel swivel.

There will be automatic drains provided at all low points of the piping. 0649925 Outlet, Front, 1.50" w/ 2" Plumbing,
Additional

ADDITIONAL FRONT DISCHARGE OUTLET
There will be one (1) 1.50" discharge outlet piped to the front of the apparatus and located on the top of the right side of the front bumper.

Plumbing will consist of 2.00" piping and flexible hose with a 2.00" full flow valve with control at the pump operator's panel. A fabricated weldment made of stainless steel pipe will be used in the plumbing where appropriate. The piping will terminate with a 1.50" NST with 90 degree stainless steel swivel.

There will be automatic drains provided at all low points of the piping. 0004995 Outlet, Rear, 2.50"

REAR DISCHARGE OUTLET
There will be One (1) discharge outlet piped to the rear of the hose bed, left side, installed so proper clearance is provided for spanner wrenches or adapters. Plumbing will consist of 2.50" piping along with a 2.50" full flow ball valve with the control from the pump operator's panel. 0045091 Elbow, Rear Outlets, 45 Degree,

2.50" FNST x 2.50" MNST, VLH

REAR OUTLET ELBOWS
The 2.50" discharge outlets located at the rear of the apparatus will be furnished with a 2.50" (F) National Standard hose thread x 2.50" (M) National Standard hose thread, chrome plated, 45 degree elbow.

The elbow will be Pierce VLH, which incorporates an exclusive thread design to automatically relieve stored pressure in the line when disconnected.
0092574 Not Required, Outlet, Rear, Additional

0085695 Not Required, Elbow, Rear Outlets,
Large, Additional
0004990 Outlet, Front HB, 2.50" w/2.50"
Plumbing

FRONT OF HOSE BED DISCHARGE OUTLET
There will be One (1) discharge outlet discharge(s) piped to the front of the hose bed and located driver side - bay 1. Plumbing will consist of 2.50" piping with a 2.50" full-flow ball valve controlled at the pump operator's panel. The discharge(s) will terminate with a 2.50" (M) National Standard hose thread adapter.

Bid #: 955 48 11.68
0752097 Caps/Plugs for 1.00" to 3.00"
Discharges/Inlets, Chain

DISCHARGE CAPS/ INLET PLUGS
Chrome plated, rocker lug, caps with chain will be furnished for all discharge outlets 1.00" thru

3.00" in size, besides the pre-connected hose outlets.

Chrome plated, rocker lug, plugs with chain will be furnished for all auxiliary inlets 1.00" thru 3.00" in size.

The caps and plugs will incorporate a thread design to automatically relieve stored pressure in the line when disconnected.
0723042 Valve, 0.75" Bleeder, Discharges, "T"
Swing Handle

OUTLET BLEEDER VALVE
A 0.75" bleeder valve will be provided for each outlet 1.50" or larger. Automatic drain valves are acceptable with some outlets if deemed appropriate with the application.

The valves will be located behind the panel with a T swing style handle control extended to the outside of the side pump panel.

The handles will be chrome plated and provide a visual indication of valve position.

The T swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage.

Bleeders will be located at the bottom of the pump panel. They will be properly labeled identifying the discharge they are plumbed in to.

The water discharged by the bleeders will be routed below the chassis frame rails. 0048403 Outlet, 3.00" Deluge Riser, Akron
Valve, w/Handwheel, w/Foam System
ByPass

DELUGE RISER
A 3.00" deluge riser will be installed above the pump in such a manner that a monitor can be mounted and used effectively. Piping will be installed securely so no movement develops when the line is charged. The riser will be gated and controlled at the pump operator's panel.

This outlet will have two (2) supply lines teed together to allow proper water flow in the water only operation and the water/foam operation. The water only piping will consist of a 3.00" ball valve.

The water/foam piping will include a 2.50" ball valve and it will be plumbed into the foam system.

The outlet will include an Akron valve with a handwheel control. 0543605 Monitor, Akron 3431 Hi-Riser and 4"
storz Inlet Grd Base

MONITOR
An Akron Model 3431 Apollo Hi-Riser monitor will be properly installed on the deluge riser. A fixed mounting base and a portable base with one (1) 4.00" Storz inlet will be provided.

A position sensor will be provided on the monitor that will activate the "do not move apparatus" light inside the cab when the monitor is in the raised position.

The monitor will be painted to match the lower body.
0046968 Nozzle, Akron 2499, Quad Stacked
Tips and 3488 Shaper

NOZZLE, DELUGE
Akron model #2499 Quad Stacked pyrolite deluge tips will be provided.

The tip sizes will be 1.375", 1.50", 1.75", and 2.00".

This will include an Akron 3488 pyrolite stream shaper. 0005072 Deluge Mount, 3" ANSI 4 Bolt Flange

The deluge riser will have a 3.00" four (4)-bolt flange for mounting the monitor. 0723726 Speedlay Module Not Required

0722432 Hose Restraint Not Required, No
Speedlay Module
0723395 Speedlays, Not Required

0723394 Speedlays, Not Required

0029167 Crosslays Sngl Sheet Unpainted,
(2+) 1.50", Std. Cap

CROSSLAY HOSE BEDS
Two (2) crosslays with 1.50" outlets will be provided. Each bed to be capable of carrying 200' of

1.75" double jacketed hose and will be plumbed with 2.00" i.d. pipe and gated with a 2.00" quarter turn ball valve.

Outlets to be equipped with a 1.50" National Standard hose thread 90 degree swivel located in the hose bed so that hose may be removed from either side of apparatus.

The crosslay controls will be at the pump operator's panel.

The center crosslay dividers will be fabricated of 0.25" aluminum and will provide adjustment from side to side. The divider will be unpainted with a brushed finish.

Vertical scuffplates constructed of stainless steel will be provided at the front and rear ends of the bed on each side of vehicle.

Crosslay bed flooring will consist of removable perforated brushed aluminum. 0029196 Not Required, 2.50" Crosslay

Bid #: 955 49 11.69
0591138 Hose Restraint, Crosslay/Deadlay,
Vinyl, Strap Fasteners, Each Side,
Ends

CROSSLAY/DEADLAY HOSE RESTRAINT
There will be black vinyl end flap provided across each end of three (3) crosslay/deadlay opening (s) to secure the hose during travel. Each vinyl end flap will be permanently attached at the top of the crosslay/deadlay opening(s). 1.00" web straps will loop through footman loops at the opposite end of the permanently attached vinyl. They will be attached with 1.00" cam buckle fasteners. 0029260 Not Required, Speedlays

0750536 Hose Restr, Spdly, Not Required, No
Spdly
0615255 Cover, Crosslay, 3/16" Alum
Treadplate, Front Hinge

CROSSLAY COVER
A hinged .19" aluminum treadplate cover will be installed over the crosslay hose beds. It will include a latch at each end of the cover to hold it securely in place, a chrome grab handle at each end for opening and closing the cover and a foam rubber gasket where the cover comes into contact to a painted surface.

The cover will be provided with no stay arm device hold open device.

The hinge will be to the front of the hose beds.
0019853 Crosslays, 8.00" Lower Than
Standard - Control Zone w/9.00"
Raised PH
CROSSLAY 8.00" LOWER THAN STANDARD
The crosslays will be lowered 8.00" from standard.
0092844 Deadlay(s), Special Cap.

DEADLAY HOSE BED
One (1) deadlay bed without plumbing, will be provided above the pump compartment capable of carrying match previous unit 28118.

Stainless steel vertical scuffplates will be provided at hose bed ends (each side of vehicle). The bottom of hose bed ends (each side) will also be equipped with a stainless steel scuffplate.

FRONT OF CROSSLAYS
Deadlay bed flooring will consist of removable perforated brushed aluminum. 0015216 Reel, Booster, Aluminum - Over
Pump, Right Side

BOOSTER HOSE REEL
A Hannay electric rewind booster hose reel will be installed over the pump in a recessed open compartment on the right side of the apparatus. The reel will be fabricated of aluminum and have highly polished end discs.

A polished stainless steel roller and guide assembly will be mounted on the reel side of the apparatus.

Discharge control will be provided at the pump operator's panel. Plumbing to the reel will consist of 1.50" Aeroquip hose and a 1.50" valve.
0011060 Switch, Reel Rewind - One at Pump
Panel
Reel motor will be protected from overload with a circuit breaker rated to match the motor.

An electric rewind control switch will be installed on the reel side pump panel. 0075300 Hose, Booster - 100' of 1.00"/800 PSI

Booster hose, 1.00" diameter and 100 feet, with chrome plated Barway, or equal couplings will be provided.

Working pressure of the booster hose will be a minimum of 800 psi. 0025244 Capacity, Hose Reel 100' of 1"

Capacity of the hose reel will be 100 feet of 1.00" booster hose. 0007428 Nozzle for Booster Reel Not Req'd

0021954 Cutout for Reel Access, One, w/ S/S
Trim

HOSEREEL ACCESS
A cutout will be provided in the side sheet next to the booster hose reel. This cutout will allow access to the hose and provide a window to view the reel. Stainless steel trim will be mounted horizontally and vertically around the cutout.
0014047 Linkage, Reverse, Hose Reel

The control on the pump panel will be "in" when the valve is open and "out" when the valve is closed. This style control will be provided on one (1) hose reel(s). 0622237 Roller Assembly, Additional There will be one (1) additional polished stainless steel roller and guide assembly mounted LS PUMP HOUSE TOP.

Bid #: 955 50 11.70
0624939 Foam Sys, Husky 3, Single Agent,
Multi Select Feature
HUSKY 3 FOAM PROPORTIONER
A Pierce Husky® 3 foam proportioning system will be provided. The Husky 3 is an on demand, automatic proportioning, single point, direct injection system suitable for all types of Class A and B foam concentrates, including the high viscosity (6000 cps), alcohol resistant Class B foams.

Operation will be based on direct measurement of water flow, and remain consistent within the specified flows and pressures. The system will automatically proportion foam solution at rates from .1 percent to 3 percent regardless of variations in water pressure and flow, up to the maximum rated capacity of the foam concentrate pump.

The design of the system will allow operation from draft, hydrant, or relay operation.

System Capacity
The system will have the ability to deliver the following minimum foam solution flow rates at accuracies that meet or exceed NFPA requirements at a pump rating of 150 psi. 100 gpm @ 3 percent
300 gpm @ 1 percent
600 gpm @ 0.5 percent
Class A foam setting in 0.1 percent increments from 0.1 percent to 1 percent. Typical settings of 1 percent, 0.5 percent and 0.3 percent (maximum capacity will be limited to the plumbing and water pump capacity).

Control System
The system will be equipped with a digital electronic control display located on the pump operator's panel. Push button controls will be integrated into the panel to turn the system on/off, control the foam percentage, and to set the operation modes.

The percent of injection will have a preset. This preset can be changed at the fire department as desired. The percent of injection will be able to be easily changed at the scene to adjust to changing demands.

Three (3) .50 tall LEDs will display the foam percentage in numeric characters. Three (3) indicator LEDs will also be included, one (1) green, one (1) red, and one (1) yellow. The LEDs will indicate various system operation or error states.

The indications will be:

Solid Green - System On
Solid Red - Valve Position Error
Solid Yellow - Priming System
Flashing Green - Injecting Foam
Flashing Red - Low Tank Level
Flashing Yellow - Refilling Tank
The control display will house a microprocessor, which receives input from the systems water flow meter while also monitoring the position of the foam concentrate pump. The microprocessor will compare the values of the water flow versus the position/rate of the foam pump, to ensure the proportion rate is accurate. One (1) check valve will be installed in the plumbing to prevent foam from contaminating the water pump.

Hydraulic Drive System
The foam concentrate pump will be powered by an electric over hydraulic drive system. The hydraulic system and motor will be integrated into one (1) unit.

Foam Concentrate Pump
The foam concentrate pump will be of positive displacement, self-priming; linear actuated design, driven by the hydraulic system. The pump will be constructed of brass body; chrome plated stainless steel shaft, with a stainless steel piston. In order to increase longevity of the pump, no aluminum will be present in its construction.

A relief system will be provided which is designed to protect the drive system components and prevent over pressuring the foam concentrate pump.

The foam concentrate pump will have minimum capacity for 3 gpm with all types of foam concentrates with a viscosity at or below 6000 cps including protein, fluoroprotein, AFFF, FFFP, or AR-AFFF. The system will deliver only the amount of foam concentrate flow required, without recirculating foam back to the storage tank. Recirculating foam concentrate back to the storage tank can cause agitation and premature foaming of the concentrate, which can result in system failure. The foam concentrate pump will be self-priming and have the ability to draw foam concentrate from external supplies such as drums or pails.

External Foam Concentrate Connection
An external foam pick-up will be provided to enable use of a foam agent that is not stored on the vehicle. The external foam pick-up will be designed to allow continued operation after the onboard foam tank is empty, or the use of foam different than the foam in the foam tank.

Panel Mounted External Pick-Up Connection / Valve
A bronze three (3)-way valve will be provided. The unit will be mounted to the pump panel. The valve unit will function as the foam system tank to pump valve and external suction valve. The external foam pick-up will be one (1) 0.75" male connection GHT (garden hose thread) with a cap.

Pick-Up Hose
A 0.75" flexible hose with an end for insertion into foam containers will be provided. The hose will be supplied with a 0.75" female swivel GHT (garden hose thread) swivel connector. The hose will be shipped loose.

Discharges
The foam system will be plumbed to the deluge foam bypass, hose reel in right side of dunnage area, left rear outlet, front crosslay, rear crosslay and right side outlet.

System Electrical Load
The maximum current draw of the electric motor and system will be no more than 55 amperes at 12 VDC.
0012126 Not Required, CAF Compressor

Bid #: 955 51 11.71
0592527 Refill, Foam Tank, Integral, Husky 3

SINGLE FOAM TANK REFILL
The foam system's proportioning pump will be used to fill the foam tank. This will allow use of the auxiliary foam pick-up to pump the foam from pails or a drum on the ground into the foam tank. A foam shut-off switch will be installed in the fill dome of the tank to shut the system down when the tank is full. The fill operation will be controlled by a mode in the foam system controller. While the proportioner pump is filling the tank, the controller will display a flashing yellow LED to indicate that the tank is filling. When the tank is full, as determined by the float switch in the tank dome, the pump will stop and the controller will shut the yellow LED off. If it attempted to use tank fill and the refill valve and suction valve are in the wrong position(s), then a red LED will illuminate to indicate the improper valve position(s). When the valves are positioned properly, then filling will commence.
0031896 Demonstration, Foam System, Dealer
Provided
0005446 Foam Cell, 20 Gallon, Not Reduce
Water

FOAM TANK
The foam tank will be an integral portion of the polypropylene water tank. The cell will have a capacity of 20 gallons of foam with the intended use of Class A foam. The foam cell will not reduce the capacity of the water tank. The foam cell will have a screen in the fill dome and a breather in the lid.
0697589 Drain, 1.00", Foam Tank #1, Husky 3
Foam System, Quarter Turn

FOAM TANK DRAIN
The foam tank drain will be a 1.00" quarter turn drain valve located inside the pump/plumbing compartment.
0091079 Not Required, Foam Tank #2

0091112 Not Required, Foam Tank #2 Drain

0738072 Approval Dwg, Pump Panel(s), Not
Required
0032479 Pump Panel Configuration, Control
Zone

PUMP PANEL CONFIGURATION
The pump panel configuration will be arranged and installed in an organized manner that will provide user-friendly operation.
0629252 Material, Pump Panels, Side Control
Black Vinyl

PUMP AND GAUGE PANEL
The pump and gauge panels will be constructed of aluminum with a black vinyl finish. A polished aluminum trim molding will be provided around each panel. 0721772 Panel, Pump Access - Right Side,
Side Control

PUMP ACCESS
Right Side Panel
The right side pump panel will be removable.

Panel Fastener
The right side removable panel will be secured using a black lift and turn latch .

The left side pump panels will be attached with screws.

The right side lower panel (drain bank) will be secured using screws. 0583824 Light, Pump Compt, Wln 3SC0CDCR
LED White

PUMP COMPARTMENT LIGHT
There will be two (2) Whelen®, Model 3SC0CDCR, 3.00" white 12 volt DC LED light(s) with Whelen, Model 3FLANGEC, flange(s) installed in the pump compartment. 0536401 Gauges, Engine, Included With
Pierce Pressure Controller

Engine monitoring graduated LED indicators will be incorporated with the pressure controller. 0005601 Throttle, Engine, Incl'd w/Press
Controller
0739224 Indicator Light @ Pump Panel,
Throttle Ready, Incl w/Pressure
Gov/Throttle,Green

THROTTLE READY GREEN INDICATOR LIGHT
There will be a green indicator light integrated with the pressure governor and/or engine throttle installed on the pump operators panel that is activated when the pump is in throttle ready mode. 0549333 Indicators, Engine, Included with
Pressure Controller
Bid #: 955 52 11.72
0745568 Indicator Light, Pump Panel, Ok To
Pump, Green

OK TO PUMP INDICATOR LIGHT
There will be a green indicator light installed on the pump operators panel that is activated when the pump is in Ok To Pump mode.
0049174 Compartment, Cab Lift Control, Pump
Panel, S/S Door

COMPARTMENT, CAB LIFT CONTROL PANEL
A compartment will be provided at the pump panel, right side. This compartment will be large enough to house the control panel for the cab lift. A stainless steel door will be provided. 0511078 Gauges, 4.00" Master, Class 1, 30"-0
-600psi

VACUUM AND PRESSURE GAUGES
The pump vacuum and pressure gauges will be liquid filled and manufactured by Class 1 Incorporated ©.

The gauges will be a minimum of 4.00" in diameter and will have white faces with black lettering, with a pressure range of 30.00"-0-600#.

Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded retaining nut.

The pump pressure and vacuum gauges will be installed adjacent to each other at the pump operator's control panel.

Test port connections will be provided at the pump operator's panel. One will be connected to the intake side of the pump, and the other to the discharge manifold of the pump. They will have 0.25 in. standard pipe thread connections and non-corrosive polished stainless steel or brass plugs.

They will be marked with a label.

This gauge will include a 10 year warranty against leakage, pointer defect, and defective bourdon tube.
0511100 Gauge, 2.00" Pressure, Class 1, 30"-
0-400psi

PRESSURE GAUGES
The individual "line" pressure gauges for the discharges will be Class 1© interlube filled.

They will be a minimum of 2.00" in diameter and have white faces with black lettering.

Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded retaining nut.

Gauges will have a pressure range of 30"-0-400#.

The individual pressure gauge will be installed as close to the outlet control as practical.

This gauge will include a 10 year warranty against leakage, pointer defect, and defective bourdon tube.
0536428 Gauge, Water Level, Pierce, In
pressure Controller

WATER LEVEL GAUGE
An electric water level gauge will be incorporated in the pressure controller that registers water level by means of 9 LEDs. They will be at 1/8 level increments with a tank empty LED. The LEDs will be a bright type that is readable in sunlight, and have a full 180-degree of clear viewing.

To further alert the pump operator, the gauge will have a warning flash when the tank volume is less than 25%, and will have "Down Chasing LEDs when the tank is almost empty.

The level measurement will be ascertained by sensing the head pressure of the fluid in the tank or cell.
0084763 Gauge, Ernst Sight Water Level,
w/Red Ball, IATS

WATER LEVEL GAUGE, ADDITIONAL
An additional water level gauge will be provided. An Ernst sight tube water level indicator with a floating red ball will be mounted on the gauge panel with an unrestricted view for the operator. 0604354 Gauge, Foam Level, FRC, Tank
Vision Pro, WLA 360-A00, Class "A"

CLASS "A" FOAM LEVEL GAUGE
A Fire Research TankVision Pro model WLA360-A00 cell/tank level indicator kit will be installed on the pump operators panel. The kit will include an electronic indicator module, a pressure sensor, a 10' sensor cable and a tank vent. The indicator will show the volume of Class "A" foam concentrate in the cell/tank on nine (9) easy to see super bright RGB LEDs. A wide view lens over the LEDs will provide for a viewing angle of 180 degrees. The indicator case will be waterproof, manufactured of Polycarbonate/Nylon material and have a distinctive green label.

The program features will be accessed from the front of the indicator module. The program will support self-diagnostics capabilities, self-calibration, six (6) programmable colored light patterns to display cell/tank volume, adjustable brightness control levels and a data link to connect remote indicators. Low foam level warnings will include flashing LEDs at 1/4 cell/tank and down chasing LEDs when the cell/tank is almost empty.

The indicator will receive an input signal from an electronic pressure sensor. The sensor will be mounted from the outside of the foam cell/tank near the bottom. No probe will be placed on the interior of the cell/tank. Wiring will be weather resistant and have automotive type plug-in connectors.

Bid #: 955 53 11.73
0682503 Light Shield/Step 8", LED, P25 LED
Stp Lt

STEP/LIGHT SHIELD
There will be an aluminum treadplate stepping surface no less than 8.00" deep and properly reinforced to support a man's weight, installed over the pump operators panel.

There will be 12 volt DC white LED lights installed under the step to illuminate the controls, switches, essential instructions, gauges, and instruments necessary for the operation of the apparatus. These lights will be activated by the pump panel light switch. Additional lights will be included every 18.00" depending on the size of the pump house.

One (1) pump panel light will come on when the pump is in ok to pump mode.

There will be a light activated above the pump panel light switch when the parking brake is applied. This is to afford the operator some illumination when first approaching the control panel.

There will be one (1) white LED, step light provided above this step. In order to ensure exceptional illumination, each step light will provide a minimum of 25 foot-candles (fc) covering an entire 15.00" x 15.00" square placed 10.00" below the light and a minimum of 1.5 fc covering an entire 30.00" x 30.00" square at the same 10.00" distance below the light. The step light will be activated by the pump panel light switch.
0682498 Light Shield/Step 8", PS LED, P25
LED Stp Lt

ADDITIONAL STEP/LIGHT SHIELD
There will be an additional aluminum treadplate stepping surface no less than 8.00" deep and properly reinforced to support a man's weight, installed over the passenger's side pump panel.

There will be 12 volt DC white LED lights installed under the step to illuminate the controls, switches, essential instructions, gauges, and instruments necessary for the operation of the apparatus. These lights will be activated by the pump panel light switch. Additional lights will be included every 18.00" depending on the size of the pump house.

There will be one (1) white LED, step light provided above the step. In order to ensure exceptional illumination, each step light will provide a minimum of 25 foot-candles (fc) covering an entire 15.00" x 15.00" square placed 10.00" below the light and a minimum of 1.5 fc covering an entire 30.00" x 30.00" square at the same 10.00" distance below the light. The step light will be activated by the pump panel light switch.
0508020 Air Horn, (1) Hadley, 6" Round,
eTone, In Bumper

AIR HORN SYSTEM
One (1) Hadley round air horn with 6.00" bell will be recessed in the front bumper. The air horn system will be piped to the air brake system wet tank utilizing 0.38" tubing. A pressure protection valve will be installed to prevent the loss of air in the brake system. 0606840 Location, Air Horn, Bumper, Left Side,
Inside Frame (Pos #5)
Air Horn Location
The air horn will be located on the left side of the bumper, inside of the frame rail. 0757092 Control, Air Horn, Multi Select

Air Horn Control
The air horn(s) will be activated by the following:
0757077 Control, Air Horn, Lanyard, LS

Left side lanyard. The lanyard to be a nylon rope.
0757080 Control, Air Horn, Ft Sw, RS

Right side foot switch
0757084 Control, Air Horn, Horn Ring

Steering wheel horn ring with electric/air horn selector switch 0006129 Siren, Code 3 3672, 100W or 200W ELECTRONIC SIREN A "Code 3", model 3672, electronic siren with noise canceling microphone will be provided.

This siren to be active when the battery switch is on and that emergency master switch is on. 0692039 Location, Electronic Siren, Center
Console Electronic siren head will be located in the center console. 0076156 Control, Elec Siren, Head Only The electronic siren will be controlled on the siren head only. No horn button or foot switches will be provided.
0601375 Speaker, (1) Code 3, PB100C,
Chrome

SPEAKER
There will be one (1) Code 3®, Model PB100C, speaker with chrome finish provided. The speaker will be connected to the siren amplifier.
0601560 Location, Speaker, Frt Bumper,
Recessed, Right Side, Inside Frame
(Pos 3)
The speaker will be recessed in the right side of the front bumper, inside of the frame rail.

Bid #: 955 54 11.74
0895310 Siren, Federal Q2B

AUXILIARY MECHANICAL SIREN
There will be a Federal Signal Model Q2B mechanical siren furnished and installed in the front of the apparatus.

The Q2B will be chrome finish.

The siren will have a 2-gauge cable connected to a power solenoid that is connected by a 2- gauge cable ran battery direct to the primary chassis batteries and will be labeled Q2B+ at the battery. The power solenoid will only be enabled when the emergency master switch is on.

The siren will have a 2-gauge ground wire connected to the chassis battery stud. The cable will be labeled Q2B- at the battery.
0006097 Location of Siren, Recessed in
Bumper
The mechanical siren will be recessed in the front bumper in the center. The siren will be properly supported using the bumper framework.
0748305 Control, Mech Siren, Multi Select

MECHANICAL SIREN CONTROL
The mechanical siren will be activated by the following:
0748281 Control Mech Siren, Ft Sw RS

Right side foot switch.
0748282 Control, Mech Siren, Ft Sw LS Left side foot switch. 0736691 Sw, Siren Brake, Momentary Chrome
Push Button, LS
A momentary chrome push button switch will be included in the left side dash panel to activate the siren brake.
0740391 Sw, Siren Brake, Momentary Chrome
Push Button, RS
A momentary chrome push button switch will be included in the right side dash panel to activate the siren brake.
0032018 Bracket, Wedge Style, Foot Switches BRACKET, FOOT SWITCHES A wedge style bracket will be provided on the driver and officer's side of cab floor.

Each bracket will be large enough to hold the foot switches picked in this order, in the following location:
one (1) footswitch on the driver side and two (2) footswitches on the officer side, 0746353 Not Required, Warning Lights
Intensity
0773930 SP Lightbar, Wln, Freedom IV-Q, 92",
RRRWRWRsr_Opt_srRWRWRRR

FRONT Zone UPPER WARNING LIGHTS
There will be one (1) 92.00" Whelen® Freedom IV lightbar mounted on the cab roof.

The lightbar will include the following:
one (1) red flashing LED module in the left side end position one (1) red flashing LED module in the left side front corner position one (1) red flashing LED module in the left side first front position one (1) white flashing LED module in the left side second front position one (1) red flashing LED module in the left side third front position one (1) white flashing LED module in the left side fourth front position one (1) red flashing LED module in the left side fifth front position one (1) steady red LED module in the left side sixth front position one (1) open in the left side seventh front position
one (1) 795 traffic light controller set to national standard high priority in the front center positions one (1) open in the right side seventh front position
one (1) steady red LED module in the right side sixth front position one (1) red flashing LED module in the right side fifth front position one (1) white flashing LED module in the right side fourth front position one (1) red flashing LED module in the right side third front position one (1) white flashing LED module in the right side second front position one (1) red flashing LED module in the right side first front position one (1) red flashing LED module in the right side front corner position one (1) red flashing LED module in the right side end position There will be clear lenses included on the lightbar.

The following switches may be installed in the cab on the switch panel to control the lightbar:
a switch to control the flashing LED modules.
the traffic light controller will be activated by a cab switch with emergency master control there will be a driver's side momentary cab switch with no emergency master control to activate the traffic light controller
The four (4) white flashing LED modules and the traffic light controller will be deactivated when the parking brake is applied.

The six (6) red flashing LED modules in the front positions may be load managed when the parking brake is applied.

Bid #: 955 55 11.75
0734071 Lights, Front Zone, Wln M6** M6**
M6** M6** LED, Q Bzl, 4lts

LIGHTS, FRONT ZONE LOWER
There will be four (4), Whelen® Model M6** 4.32" high x 6.75" wide x 1.37" deep flashing LED warning lights installed on the cab face above the headlights in twin bezels.

The left side outside warning light to include red LEDs The left side inside warning light to include red LEDs
The right side inside warning light to include red LEDs The right side outside warning light to include red LEDs The warning light lens color(s) to be clear
The housing to be polished and the trim shall be chrome The lights may be controlled per the following:

A switch on the cab instrument panel will control the lights White LEDs will be deactivated when the parking brake is applied Amber LEDs will be activated when the parking brake is applied Amber, blue green or red LEDs in the inside positions may be load managed when the parking brake is applied
0558676 Daytime Running Lights, Headlights,
Qtm, Vel/Imp, Enf/AXT-MUX, DCF
(Low Beam)

DAYTIME RUNNING LIGHTS (HEADLIGHTS)
The low-beam headlights used as daytime running lights will be activated with the following measures:

Ignition switch is turned on
Parking brake is released
These lights will be deactivated with any one of the following measures:

Headlight switch is turned on
High-beam flash is turned on
Parking brake is set
0653937 Flasher, Headlight Alternating HEADLIGHT FLASHER The high beam headlights will flash alternately between the left and right side.

There will be a switch installed in the cab on the switch panel to control the high beam flash. This switch will be live when the battery switch and the emergency master switches are on.

The flashing will automatically cancel when the hi-beam headlight switch is activated or when the parking brake is set.
0747228 Lights, Side Zone Lower, Wln M6**,
M6**, M6**, 6Lts

SIDE ZONE LOWER LIGHTING
There will be six (6) Whelen®, Model M6**, 4.31" high x 6.75" long x 1.37" deep flashing LED warning lights with chrome trim installed per the following:

Two (2) lights located, one (1) each side on the bumper extension. The driver's side, side front light to include red warning LEDs and the passenger's side, side front light to include red warning LEDs.

Two (2) lights located, one (1) each side of cab rearward of crew cab doors. The driver's side, side middle light to include red warning LEDs and the passenger's side, side middle light to include red warning LEDs.

Two (2) lights located, one (1) each side above rear wheels. The driver's side, side rear light to include red warning LEDs and the passenger's side, side rear light to include red warning LEDs.

The warning light lens color(s) to be clear.

There will be a switch in the cab on the switch panel to control the lights. 0564655 Lights, Rear Zn Lwr, Wln M6*C LED,
Clear Lens, For Tail Lt Housing

REAR ZONE LOWER LIGHTING
There will be two (2) Whelen®, Model M6*C, LED flashing warning lights located at the rear of the apparatus.

The driver's side rear light to be red
The passenger's side rear light to be red
Both lights will include a lens that is clear.

There will be a switch located in the cab on the switch panel to control the lights. 0686562 Light, Rear Zone Up, Wln MCFLED2*
LED

REAR UPPER ZONE WARNING LIGHTS
There will be two (2) Whelen, Model MCFLED2* LED warning beacons provided at the rear of the truck, one (1) each side.

The color of the lights will be:

The rear upper light(s) on the driver's side to be red.

The rear upper light(s) on the passenger's side to be red.

All lenses will be clear.

There will be a switch located in the cab on the switch panel to control the beacons. 0006551 Not Required, Lights, Rear Upper
Zone Blocking
0006615 Mounting, Rear Warn Lights, On Top
of Compartment
The rear warning lights will be mounted on top of the compartmentation with all wiring totally enclosed. The rear deck lights will be mounted on the beavertails as high as possible.

Bid #: 955 56 11.76
0791493 Light, Traffic Directing, Wln TAM65
36" Long LED

TRAFFIC DIRECTING LIGHT
There will be one (1) Whelen® Model TAM65, 36.00" long x 2.87" high x 2.25" deep, amber LED traffic directing light installed at the rear of the apparatus.

The Whelen Model TACTL5 control head will be included with this installation.

The control head will be energized when the battery switch is on.

The auxiliary flash not activated.
0529858 Location, TDL, Recessed Within
Treadplate Step
This traffic directing light will be recessed within a treadplate step at the rear of the apparatus. 0530281 Location, Traf Dir Lt Controller,
Center Console in Sw Pnl

The traffic directing light controller will be located within the switch panel on the center console.

The controller will be within easy reach of the driver. 0810757 SP Light Twr, W-B Chf NS1.8-300 WHL,
2-P*H2 12VDC Lts Cld 6'

LIGHT TOWER
There will be one (1) Will-Burt, Model NS1.8-2 WHL, light tower provided.

There will be two (2) Whelen, Model P*H2, 17,750 lumens 12 volt DC light heads with a combination of flood and spot optics included on this tower.

The painted parts of the light tower and the light heads to be white.

This tower will be connected to the Do Not Move Truck Indicator in the cab.

The lights included on this tower may be load managed when the parking brake is applied. 0664472 Location, Light Tower, Crew Cab
Roof
Light Tower Location
The light tower will be installed on the crew cab roof. 0617750 Controller, Lt Twr, W-B, Wired
Hndhld, E-STOP Chf, Chf Pr, Pow Pr

Light Tower Controller
There will be one (1) handheld wired controller included. 0664791 Location, Light Tower Controller,
Driver's Side Front Body
Compartment
Light Tower Controller Location
The light tower controller will be installed in the driver's side front body compartment. 0775556 Receptacle, 15A 120V 3-Pr 3-Wr SB
Dup, Surge Prot Shoreline

120 VOLT RECEPTACLE
There will be one (1), 15 amp 120 volt AC three (3) wire straight blade duplex receptacle(s) with blue interior cover plate installed RS3 PER PROVIDED PICTURE in stage 7. The NEMA configuration for the receptacles will be 5-15R. The blue face on the receptacle plate will be provided to indicate the receptacle is surge protected.

The receptacle will absorb a transient surge of 500 volts minimum. A damage alert alarm sounds when surge protection is no longer functioning and keeps sounding until the receptacle is repaired.

A power on indicator light indicates that power is available and the suppression circuit is in operation.

The receptacle(s) will be powered from the shoreline inlet.

There will be a label installed near the receptacle(s) that state the following:

Line Voltage
Current Ratting (amps)
Phase
Frequency
0519934 Not Required, Brand, Hydraulic Tool
System
0649753 Not Required, PTO Driven Hydraulic
Tool System
0007150 Bag of Nuts and Bolts

LOOSE EQUIPMENT
The following equipment will be furnished with the completed unit:

One (1) bag of chrome, stainless steel, or cadmium plated screws, nuts, bolts and washers, as used in the construction of the unit.

Bid #: 955 57 11.77
0816508 NFPA Required Loose Equipment,
Pumper, NFPA 2024, Provided by
Fire Department

NFPA LOOSE EQUIPMENT
NFPA Required Loose Equipment Provided by Fire Department The following loose equipment as outlined in NFPA 1900, 2024 edition, table 8.1 will be provided by the fire department:

One (1) traffic vest for each seating position, each vest to comply with ANSI/ISEA 207, Standard for High Visibility Public Safety Vests, and have a five-point breakaway feature that includes two (2) at the shoulders, two (2) at the sides, and one (1) at the front.

Five (5) fluorescent orange traffic cones not less than 28.00" (711 mm) in height, each equipped with a 6.00" (152 mm) retro-reflective white band no more than 4.00" (152 mm) from the top of the cone, and an additional 4.00" (102 mm) retro-reflective white band 2.00" (51 mm) below the

6.00" (152 mm) band.

Five (5) illuminated warning devices such as highway flares, unless the five (5) fluorescent orange traffic cones have illuminating capabilities.

NFPA Loose Equipment That Shall be Considered:

The following loose equipment as outlined in NFPA 1900, 2024 edition, appendix table A.8.4 (a) should be considered:
800 ft (60 m) of 2.50" (65 mm) or larger fire hose.
400 ft (120 m) of 1.50" (38 mm), 1.75" (45 mm), or 2.00" (52 mm) fire hose.

One (1) handline nozzle, 200 gpm (750 L/min) minimum.

Two (2) handline nozzles, 95 gpm (360 L/min) minimum.

One (1) smooth bore or combination nozzle with shutoff and with 2.50" (65 mm) inlet that flows a minimum of 250 gpm (950 L/min).

Four (4) SCBA apparatus
Four (4) SCBA spare cylinders
One (1) first aid kit.

Four (4) combination spanner wrenches.

Two (2) hydrant wrenches.

One (1) double female 2.50" (65 mm) adapter with national hose (NH) threads.

One (1) double male 2.50" (65 mm) adapter with national hose (NH) threads.

One (1) rubber mallet, for use on suction hose connections.

Two (2) salvage covers each a minimum size of 12 ft × 18 ft (3.7 m × 5.5 m).

One (1) automatic external defibrillator (AED).
0519913 Not Required, Soft Suction Hose

SOFT SUCTION HOSE
There will be no soft suction hose provided.
0821565 Strainer, Provided by Fire
Department, Pumper NFPA 2024
Classification

STRAINER PROVIDED BY FIRE DEPARTMENT
NFPA 1900, 2024 edition, section 8.3 requires a suction strainer when suction hose is provided.

The strainer is not on the apparatus as manufactured. The fire department will provide the suction strainer.
0816939 Extinguisher, Dry Chemical, NFPA
2024, Provided by Fire Department

DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0816937 Extinguisher, 2.5 Gal. Pressurized
Water, NFPA 2024, Provided by Fire
Department

WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0816998 Axe, Flathead, Provided by Fire
Department

FLATHEAD AXE PROVIDED BY FIRE DEPARTMENT
The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe.
0817000 Axe, Pickhead, Provided by Fire
Department

PICKHEAD AXE PROVIDED BY FIRE DEPARTMENT
The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe.

Bid #: 955 58 11.78
0741569 Paint Process / Environmental
Requirements, Appleton

PAINT PROCESS
The exterior custom cab and body painting procedure will consist of a seven (7) step finishing process as follows:

Manual Surface Preparation - All exposed metal surfaces on the custom cab and body will be thoroughly cleaned and prepared for painting. Imperfections on the exterior surfaces will be removed and sanded to a smooth finish. Exterior seams will be sealed before painting. Exterior surfaces that will not be painted include; chrome plating, polished stainless steel, anodized aluminum and bright aluminum treadplate.

Chemical Cleaning and Pretreatment - All surfaces will be chemically cleaned to remove dirt, oil, grease, and metal oxides to ensure the subsequent coatings bond well. The aluminum surfaces will be properly cleaned and treated using a high pressure, high temperature 4 step Acid Etch process. The steel and stainless surfaces will be properly cleaned and treated using a high temperature 3 step process specifically designed for steel or stainless. The chemical treatment converts the metal surface to a passive condition to help prevent corrosion.

Surfacer Primer - The Surfacer Primer will be applied to a chemically treated metal surface to provide a strong corrosion protective basecoat. A minimum thickness of 2 mils of Surfacer Primer is applied to surfaces that require a Critical aesthetic finish. The Surfacer Primer is a twocomponent high solids urethane that has excellent sanding properties and an extra smooth finish when sanded.

Finish Sanding - The Surfacer Primer will be sanded with a fine grit abrasive to achieve an ultrasmooth finish. This sanding process is critical to produce the smooth mirror like finish in the topcoat.

Sealer Primer - The Sealer Primer is applied prior to the Basecoat in all areas that have not been previously primed with the Surfacer Primer. The Sealer Primer is a two-component high solids urethane that goes on smooth and provides excellent gloss hold out when topcoated.

Basecoat Paint - Two coats of a high performance, two component high solids polyurethane basecoat will be applied. The Basecoat will be applied to a thickness that will achieve the proper color match. The Basecoat will be used in conjunction with a urethane clear coat to provide protection from the environment.

Clear Coat - Two (2) coats of Clear Coat will be applied over the Basecoat color. The Clear Coat is a two-component high solids urethane that provides superior gloss and durability to the exterior surfaces. Lap style and roll-up doors will be Clear Coated to match the body. Paint warranty for the roll-up doors will be provided by the roll-up door manufacturer.

After the cab and body are painted, the color will be verified to make sure that it matches the color standard. Electronic color measuring equipment will be used to compare the color sample to the color standard entered into the computer. Color specifications will be used to determine the color match. A Delta E reading will be used to determine a good color match within each family color.

All removable items such as brackets, compartment doors, door hinges, and trim will be removed and painted separately if required, to ensure paint behind all mounted items. Body assemblies that cannot be finish painted after assembly will be finish painted before assembly.

The paint finish quality levels for critical areas of the apparatus (cab front and sides, body sides and doors, and boom lettering panels) are to meet or exceed Cadillac/General Motors GMW15777 global paint requirements. Orange peel levels are to meet or exceed the #6 A.C.T. standard in critical areas. The manufacture's written paint standards will be available upon request.

Environmental Impact
Contractor will meet or exceed all current state regulations concerning paint operations. Pollution control will include measures to protect the atmosphere, water and soil. Controls will include the following conditions:

Topcoats and primers will be chrome and lead free.

Metal treatment chemicals will be chrome free. The wastewater generated in the metal treatment process will be treated on-site to remove any other heavy metals.

Particulate emission collection from sanding operations will have a 99.99 percent efficiency factor.

Particulate emissions from painting operations will be collected by a dry filter or water wash process. If the dry filter is used, it will have an efficiency rating of 98 percent. Water wash systems will be 99.97 percent efficient
Water from water wash booths will be reused. Solids will be removed on a continual basis to keep the water clean.

Paint wastes are disposed of in an environmentally safe manner.

Empty metal paint containers will be recycled to recover the metal.

Solvents used in clean-up operations will be recycled on-site or sent off-site for distillation and returned for reuse.

Additionally, the finished apparatus will not be manufactured with or contain products that have ozone depleting substances. Contractor will, upon demand, present evidence that the manufacturing facility meets the above conditions and that it is in compliance with his state EPA rules and regulations.
0709566 Paint, Two-Tone Color, Enforcer

TWO-TONE CAB PAINT
The cab will be painted two-tone with the upper section painted #10 white and the lower section painted #90 red. There will be a standard two-tone cab paint break provided.

There will be no cab shield provided.
0709845 Paint, Single Color, Body

BODY PAINT
The body will be painted to match the lower section of the cab.

Bid #: 955 59 11.79
0646901 Paint Chassis Frame Assy, With
Liner, E-Coat, Standard

PAINT CHASSIS FRAME ASSEMBLY
The chassis frame assembly will be finished with a single system black top coat before the installation of the cab and body, and before installation of the engine and transmission assembly, air brake lines, electrical wire harnesses, etc.

Components that are included with the chassis frame assembly that will be painted are:

Frame rails
Frame liners
Cross members
Axles
Suspensions
Steering gear
Battery boxes
Bumper extension weldment
Frame extensions
Body mounting angles
Rear Body support substructure (front and rear)
Pump house substructure
Steel fuel tank
Castings
Individual piece parts used in chassis and body assembly Components treated with epoxy E-coat protection prior to paint:

Two (2) C-channel frame rails
Two (2) frame liners
The E-coat process will meet the technical properties shown. 0693798 Paint, Front Wheels FRONT WHEELS PAINT
All wheel surfaces, inside and outside, will be provided with powder coat paint #90 red. 0693793 Paint, Rear Wheels, Single Axle REAR WHEELS PAINT All wheel surfaces, inside and outside, will be provided with powder coat paint #90 red. 0733739 Paint, Axle Hubs

AXLE HUB PAINT
All axle hubs will be painted to match lower job color. 0007230 Compartment, Painted, Spatter Gray

COMPARTMENT INTERIOR PAINT
The interior of all compartments will be painted with a gray spatter finish for ease of cleaning and to make it easier to touch up scratches and nicks.
0544124 Reflective Band, 1"-4"-1"

REFLECTIVE STRIPES
Three (3) reflective stripes will be provided across the front of the vehicle and along the sides of the body. The reflective band will consist of a 1.00" white stripe at the top with a 1.00" gap then a

4.00" white stripe with a 1.00" gap and a 1.00" white stripe on the bottom. 0007356 Reflective across Cab Face

The reflective band provided on the cab face will be at the headlight level. 0536954 Stripe, Chevron, Rear, Diamond
Grade, Pumper

REAR CHEVRON STRIPING
There will be alternating chevron striping located on the rear-facing vertical surface of the apparatus. The rear surface, excluding the rear compartment door, will be covered.

The colors will be red and yellow diamond grade.

Each stripe will be 6.00" in width.

This will meet the requirements of the current edition of NFPA 1901, which states that 50% of the rear surface will be covered with chevron striping.
0065687 Stripe, Reflective, Cab Doors Interior

CAB DOOR REFLECTIVE STRIPE
A 6.00" x 16.00" black reflective stripe will be provided across the interior of each cab door. The stripe will be located approximately 1.00" up from the bottom, on the door panel.

This stripe will meet the NFPA 1901 requirement.
0033179 Lettering Specifications, Reflective

0686159 Lettering, Reflective, 3.00", (41-60)

LETTERING
Forty-one (41) to sixty (60) reflective lettering, 3.00" high, with outline and shade will be provided. 0686013 Lettering, Reflective, 6.00", Each

LETTERING
There will be reflective lettering, 6.00" high, with outline and shade provided. There will be 24 letters provided.

Bid #: 955 60 11.80
0686018 Lettering, Reflective, 5.00", Each

LETTERING
There will be reflective lettering, 5.00" high, with outline and shade provided. There will be eight (8) letters provided.
0686033 Lettering, Reflective, 4.00", Each

LETTERING
There will be reflective lettering, 4.00" high, with outline and shade provided. There will be 21 letters provided.
0772003 Manual, Fire Apparatus Parts, USB
Flash Drive, Custom

FIRE APPARATUS PARTS MANUAL
There will be one (1) custom parts manual(s) in USB flash drive format for the complete fire apparatus provided.

The manual(s) will contain the following:

Job number
Part numbers with full descriptions
Table of contents
Parts section sorted in functional groups reflecting a major system, component, or assembly Parts section sorted in alphabetical order
Instructions on how to locate parts
Each manual will be specifically written for the chassis and body model being purchased. It will not be a generic manual for a multitude of different chassis and bodies.

Service Parts Internet Site
The service parts information included in these manuals are also available on the Pierce website.

The website offers additional functions and features not contained in this manual, such as digital photographs and line drawings of select items. The website also features electronic search tools to assist in locating parts quickly.
0772037 Manual, Chassis Service, USB Flash
Drive, Custom

CHASSIS SERVICE MANUALS
There will be one (1) chassis service manuals on USB flash drives containing parts and service information on major components provided with the completed unit.

The manual will contain the following sections:

Job number
Table of contents
Troubleshooting
Front Axle/Suspension
Brakes
Engine
Tires
Wheels
Cab
Electrical, DC
Air Systems
Plumbing
Appendix
The manual will be specifically written for the chassis model being purchased. It will not be a generic manual for a multitude of different chassis and bodies. 0773381 Manual, Chassis Operation, (1) USB
Flash Drive, Custom

CHASSIS OPERATION MANUAL
The chassis operation manual will be provided on one (1) USB flash drive. 0030008 Warranty, Basic, 1 Year, Apparatus,
WA0008
ONE (1) YEAR MATERIAL AND WORKMANSHIP
A Pierce basic apparatus limited warranty certificate, WA0008, is included with this proposal. 0696698 Warranty, Engine, Cummins, 5 Year,
WA0181

ENGINE WARRANTY
A Cummins five (5) year limited engine warranty will be provided. A limited warranty certificate, WA0181, is included with this proposal.
0684953 Warranty, Steering Gear, Sheppard
M110, 3 Year WA0201

STEERING GEAR WARRANTY
A Sheppard three (3) year limited steering gear warranty will be provided. A copy of the warranty certificate will be submitted with this proposal.
0596017 Warranty, Frame, 50 Year, Custom
Chassis, WA0013
FIFTY (50) YEAR STRUCTURAL INTEGRITY
The Pierce custom chassis frame limited warranty certificate, WA0013, is included with this proposal.
0595698 Warranty, Axle, 3 Year, TAK-4,
WA0050
FRONT AXLE THREE (3) YEAR MATERIAL AND WORKMANSHIP WARRANTY The Pierce TAK-4 suspension limited warranty certificate, WA0050, is included with this proposal. 0733306 Warranty, Single Axle, 5 Year, Meritor,
General Service, WA0384
SINGLE REAR AXLE FIVE (5) YEAR MATERIAL AND WORKMANSHIP WARRANTY A Meritor™ Axle 5 year limited warranty will be provided.

Bid #: 955 61 11.81
0652758 Warranty, ABS Brake System, 3 Year,
Meritor Wabco, WA0232
ABS BRAKE SYSTEM THREE (3) YEAR MATERIAL AND WORKMANSHIP WARRANTY A Meritor Wabco™ ABS brake system limited warranty certificate, WA0232, is included with this proposal.
0019914 Warranty, Structure, 10 Year, Custom
Cab, WA0012
TEN (10) YEAR STRUCTURAL INTEGRITY
The Pierce custom cab limited warranty certificate, WA0012, is included with this proposal. 0744240 Warranty, Paint, 10 Year, Cab, ProRate, WA0055 TEN (10) YEAR PRO-RATED PAINT AND CORROSION A Pierce cab limited pro-rated paint warranty certificate, WA0055, is included with this proposal. 0524627 Warranty, Electronics, 5 Year, MUX,
WA0014
FIVE (5) YEAR MATERIAL AND WORKMANSHIP
The Pierce Command Zone electronics limited warranty certificate, WA0014, is included with this proposal.
0695416 Warranty, Pierce Camera System,
WA0188

CAMERA SYSTEM WARRANTY
A Pierce fifty four (54) monthwarranty will be provided for the camera system. 0647720 Warranty, Pierce LED Strip Lights,
WA0203

COMPARTMENT LIGHT WARRANTY
The Pierce 12 volt DC LED strip lights limited warranty certificate, WA0203, is included with this proposal.
0046369 Warranty, 5-year EVS Transmission,
Standard Custom, WA0187

TRANSMISSION WARRANTY
The transmission will have a five (5) year/unlimited mileage warranty covering 100 percent parts and labor. The warranty will be provided by Allison Transmission.

Note: The transmission cooler is not covered under any extended warranty you may be getting on your Allison Transmission. Please review your Allison Transmission warranty for coverage limitations.
0685945 Warranty, Transmission Cooler,
WA0216

TRANSMISSION COOLER WARRANTY
The transmission cooler will carry a five (5) year parts and labor warranty (exclusive to the transmission cooler). In addition, a collateral damage warranty will also be in effect for the first three (3) years of the warranty coverage and will not exceed $10,000 per occurrence. A copy of the warranty certificate will be included with this proposal. 0688798 Warranty, Water Tank, Lifetime, UPF,
Poly Tank, WA0195

WATER TANK WARRANTY
A UPF poly water tank limited warranty certificate, WA0195, is included with this proposal. 0596025 Warranty, Structure, 10 Year, Body,
WA0009
TEN (10) YEAR STRUCTURAL INTEGRITY
The Pierce apparatus body limited warranty certificate, WA0009, is included with this proposal. 0693126 Warranty, AMDOR, Roll-up Door, 10
Year/5 Year Painted, WA0185

ROLL UP DOOR MATERIAL AND WORKMANSHIP WARRANTY
An AMDOR roll-up door limited warranty will be provided. The roll-up door will be warranted against manufacturing defects for a period of ten (10) years. A five (5) year limited warranty will be provided on painted roll up doors.

The limited warranty certificate, WA0185, is included with this proposal. 0734463 Warranty, Pump, Waterous, 7 Year
Parts, WA0382

PUMP WARRANTY
The Waterous pump will be provided with a seven (7) yearmaterial and workmanship limited warranty.

A copy of the warranty certificate will be included with this proposal. 0648675 Warranty, 10 Year S/S Pumbing,
WA0035
TEN (10) YEAR PUMP PLUMBING WARRANTY
The Pierce apparatus plumbing limited warranty certificate, WA0035, is included with this proposal.
0657990 Warranty, Foam System, Husky 3,
WA0231

FOAM SYSTEM WARRANTY
The Husky 3 foam system limited warranty certificate, WA0231, is included with this proposal. 0595820 Warranty, Paint, 10 Year, Body, ProRate, WA0057 TEN (10) YEAR PRO-RATED PAINT AND CORROSION A Pierce body limited pro-rated paint warranty certificate, WA0057, is included with this proposal.

Bid #: 955 62 11.82
0595412 Warranty, Graphics Lamination, 1
Year, Apparatus, WA0168

ONE (1) YEAR MATERIAL AND WORKMANSHIP
The Pierce graphics fading and deterioration limited warranty limited warranty certificate, WA0168, is included with this proposal.
0819254 Certification, Vehicle Stability,
CD0196

VEHICLE STABILITY CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the apparatus complies with NFPA 1900, current edition, section 7.14, Vehicle Stability. The certification is included with this proposal.
0808564 Certification, Engine Installation, Enf,
Cummins X15, 2027

ENGINE INSTALLATION CERTIFICATION
The fire apparatus manufacturer will provide a certification, along with a letter from the engine manufacturer stating they approve of the engine installation in the bidder's chassis. The certification will be provided at the time of delivery. 0686786 Certification, Power Steering,
CD0098

POWER STEERING CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the power steering system as installed meets the requirements of the component supplier. The certification is included with this proposal.
0892691 Certification, Cab Integrity, Saber
FR/Enforcer, CD0189

CAB INTEGRITY CERTIFICATION
The fire apparatus manufacturer will provide a cab crash test certification with this proposal. The certification will state that a specimen representing the substantial structural configuration of the cab has been tested and certified by an independent third party test facility. Testing events will be documented with photographs, real-time and high-speed video, vehicle accelerometers, cart accelerometers, and a laser speed trap. The fire apparatus manufacturer will provide a state licensed professional engineer to witness and certify all testing events. Testing will meet or exceed the requirements below:

SAE J2422 Cab Roof Strength Evaluation - Quasi-Static Loading Heavy Trucks.

European Occupant Protection Standard ECE Regulation No.29.

SAE J2420 COE Frontal Strength Evaluation - Dynamic Loading Heavy Trucks.

Side Impact
The cab will be subjected to dynamic preload where a 14,320-lb moving barrier is slammed into the side of the cab at 5.50 mph, striking with an impact of 13,000 ft-lb of force. This test is part of the SAE J2422 test procedure and more closely represents the forces a cab will see in a rollover incident.

Frontal Impact
The same cab will withstand a frontal impact of 32,600 ft-lb of force using a moving barrier in accordance with SAE J2420.

Additional Frontal Impact
The same cab will withstand a frontal impact of 65,098 ft-lb of force using a moving barrier. (Twice the force required by SAE J2420)
Roof Crush
The cab will be subjected to a roof crush force of 22,500 lb. This value meets the ECE 29 criteria, and is equivalent to the front axle rating up to a maximum of ten (10) metric tons.

Additional Roof Crush
The same cab will be subjected to a roof crush force of 110,000 lbs. (Four and a half times the load criteria of ECE 29)
The same cab will withstand all tests without any measurable intrusion into the survival space of the occupant area.

There will be no exception to any portion of the cab integrity certification. Nonconformance will lead to immediate rejection of bid.
0631973 Certification, Cab Door Durability,
Saber FR/Enforcer, CD0137

CAB DOOR DURABILITY CERTIFICATION
Robust cab doors help protect occupants. Cab doors will survive a 200,000 cycle door slam test where the slamming force exceeds 20 G's of deceleration. The bidder will certify that the sample doors similar to those provided on the apparatus have been tested and have met these criteria without structural damage, latch malfunction, or significant component wear. 0631978 Certification, Windshield Wiper
Durability, Saber FR/Enforcer,
CD0132

WINDSHIELD WIPER DURABILITY CERTIFICATION
Visibility during inclement weather is essential to safe apparatus performance. Windshield wipers will survive a 3 million cycle durability test in accordance with section 6.2 of SAE J198 Windshield Wiper Systems - Trucks, Buses and Multipurpose Vehicles. The bidder will certify that the wiper system design has been tested and that the wiper system has met these criteria. 0631974 Certification, Electric Window
Durability, Saber FR/Enforcer,
CD0133

ELECTRIC WINDOW DURABILITY CERTIFICATION
Cab window roll-up systems can cause maintenance problems if not designed for long service life. The window regulator design will complete 30,000 complete up-down cycles and still function normally when finished. The bidder will certify that sample doors and windows similar to those provided on the apparatus have been tested and have met these criteria without malfunction or significant component wear.

Bid #: 955 63 11.83
0631977 Certification, Seat Belt Anchors and
Mounting, Saber FR/Enforcer,
CD0134

SEAT BELT ANCHOR STRENGTH
Seat belt attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat belt anchor design will withstand 3000 lb of pull on both the lap and shoulder belt in accordance with FMVSS 571.210 Seat Belt Assembly Anchorages.

The bidder will certify that each anchor design was pull tested to the required force and met the appropriate criteria.

SEAT MOUNTING STRENGTH
Seat attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat mounting design will be tested to withstand 20 G's of force in accordance with FMVSS 571.207 Seating Systems. The bidder will certify, at time of delivery, that each seat mount and cab structure design was pull tested to the required force and met the appropriate criteria.
0735949 Certification, Cab HVAC System
Performance, SFR/Enf,
CD0165/CD0167/CD0174/CD0175

PERFORMANCE CERTIFICATIONS
Cab Air Conditioning
Good cab air conditioning temperature and air flow performance keeps occupants comfortable, reduces humidity, and provides a climate for recuperation while at the scene. The cab air conditioning system will cool the cab from a heat-soaked condition at 100 degrees Fahrenheit to an average of 78 degrees Fahrenheit in 30 minutes. The bidder will certify that a substantially similar cab has been tested and has met these criteria.

Cab Defroster
Visibility during inclement weather is essential to safe apparatus performance. The defroster system will clear the required windshield zones in accordance with SAE J381 Windshield Defrosting Systems Test Procedure And Performance Requirements - Trucks, Buses, And Multipurpose Vehicles.The bidder will certify that the defrost system design has been tested in a cold chamber and passes the SAE J381 criteria.

Cab Auxiliary Heater
Good cab heat performance and regulation provides a more effective working environment for personnel, whether in-transit, or at a scene. An auxiliary cab heater will warm the cab 77 degrees Fahrenheit from a cold-soak, within 30 minutes when tested using the coolant supply methods found in SAE J381. The bidder will certify, at time of delivery, that a substantially similar cab has been tested and has met these criteria.
0545073 Amp Draw Report, NFPA Current
Edition

AMP DRAW REPORT
The bidder will provide, at the time of bid and delivery, an itemized print out of the expected amp draw of the entire vehicle's electrical system.

The manufacturer of the apparatus will provide the following:

Documentation of the electrical system performance tests.

A written load analysis, which will include the following:

The nameplate rating of the alternator.

The alternator rating under the conditions specified per:

Current edition of applicable NFPA standards.

The minimum continuous load of each component that is specified per:

Current edition of applicable NFPA standards.

Additional loads that, when added to the minimum continuous load, determine the total connected load.

Each individual intermittent load.

All of the above listed items will be provided by the bidder per the current edition of applicable NFPA standards.
0002758 Amp Draw, NFPA/ULC Radio
Allowance
0799248 Appleton/Florida BTO

0000018 PUMPER, 2ND GEN

0000012 PIERCE CHASSIS
0004713 ENGINE, OTHER
0046396 EVS 4000 Series TRANSMISSION
0020011 WATEROUS PUMP

0020009 POLY TANK

0028048 FOAM SYSTEM
Bid #: 955 64 11.84
0020006 SIDE CONTROL
0020007 AKRON VALVES

0020015 ABS SYSTEM

0658751 PUMPER BASE

Bid #: 955 65 11.85
Option Description Type* Minimum
Load
Intermittent
Load
Total
Connected
0001244 High Idle w/Electronic Engine, Custom 0.00 1.20 0.00 0015216 Reel, Booster, Aluminum - Over Pump, Right Side 0.00 36.00 0.00 0024543 Primer, Hale, ESP Motor, (1) PVG Valve, (1) T-Handle Control, For An Other Pump

0.00 275.00 0.00
0079205 Batteries, (5) Stryten/Exide Grp 31, 950 CCA each, (1) Iso Bat, Threaded Stud

0.00 3.00 0.00
0543751 Light, Do Not Move Apparatus 0.00 0.80 0.00
0549333 Indicators, Engine, Included with Pressure Controller 0.00 0.35 0.00 0583824 Light, Pump Compt, Wln 3SC0CDCR LED White 0.00 0.72 0.00 0583938 Lights, Engine Compt, Custom, Auto Sw, Wln 3SC0CDCR, 3" LED, Trim

0.00 0.60 0.00
0589905 Alarm, Back-up Warning, PRECO 1040 0.00 0.50 0.00 0604354 Gauge, Foam Level, FRC, Tank Vision Pro, WLA 360-A00, Class "A"

0.00 0.00 1.23
0624939 Foam Sys, Husky 3, Single Agent, Multi Select Feature 0.00 55.00 0.00 0625194 Handlts, (4) Koehler, BrightStar, Responder 510318, light & charger, 12vdc

0.00 0.00 1.60
0626097 Light, Map, Sunnex HS76*-00 Series, Swivel Joint, Clear Lens, Ceiling Mount

0.00 0.00 1.56
0630636 Controls, Electric Roll-Up Windows, 4dr, 4 Driver Controls, Saber FR/Enforcer

0.00 26.00 0.00
0639727 Cab Lift, Elec/Hyd, Manual Override, Saber FR/Enforcer 0.00 180.00 0.00 0681751 Handlight, Streamlight, E- Flood LiteBox, 45805 LED, 12v Charger, Orange

0.00 0.00 1.40
0687994 Engine Brake, Jacobs Compression Brake, Cummins Engine 0.00 0.42 0.00 0723827 Radio, AM/FM/Media Receiver, Pioneer MVH-S720BHS 0.00 0.00 10.00 0727913 Spotlight, Golight/RadioRay, Model 20**4GT, LED, 2 Lts 0.00 0.00 7.40 0727946 Lights, Wln, S30M** 30" 12VDC LED, RS Cab, Mt Fet 0.00 0.00 7.20 0727947 Lights, Wln, S30M** 30" 12VDC LED, LS Cab, Mt Fet 0.00 0.00 7.20 0734681 Compt, Storage, 13.75 W x 24 H x 15 D, (1) Ea Side C/C, Single Pan, 70" SFR/Enf

0.00 0.00 0.00
0748793 Lights, Wln, S44M** 44" 12VDC, RS Body 0.00 0.00 10.80 0748795 Lights, Wln, S44M** 44" 12VDC, LS Body 0.00 0.00 10.80 0806466 Lights, Backup, Wln M62BU, LED, For Tail Lt Housing 0.00 3.20 0.00 0810757 Light Twr, W-B Chf NS1.8-300 WHL, 2-P*H2 12VDC Lts Cld 6' 0.00 0.00 23.44 0812519 Panel, Charger Display, Blue Sea, 7517 0.00 0.05 0.00 0817058 Camera, Pierce, LS Mux, R Camera, SD, CL714 0.00 1.20 0.00 0818490 Wiring, Customer Installed Solar Panel & Controller, Sunforce Crystalline w/Cntl

0.00 25.00 0.00
0820509 ESC/ABS/ATC Wabco Brake System, Single Rear Axle, NFPA 1900

0.00 6.00 0.00
0820897 Wiring, Spare, 15 A 12V DC, Batt Dir, 2nd NFPA1900 0.00 0.00 15.00 0820906 Wiring, Spare, 15 A 12V DC 2nd NFPA1900 0.00 0.00 45.00 0820907 Wiring, Spare, 15 A 12V DC 3rd NFPA1900 0.00 0.00 105.00 0895310 Siren, Federal Q2B 0.00 100.00 0.00
0722038 HVAC, Heavy-Duty, Enforcer, w/X15, CARE Load Managed 0.00 0.00 100.00 0774336 Lights, Wln, P*H1* Pioneer, 12 VDC, 1st Load Managed 0.00 0.00 13.00 0776357 Light, Visor, Wln, 12V P*H2* Pioneer, Cnt Feature, 1st Load Managed 0.00 0.00 13.00 0002758 Amp Draw, NFPA/ULC Radio Allowance NFPA 5.00 0.00 0.00 0006129 Siren, Code 3 3672, 100W or 200W NFPA 1.40 12.60 0.00 0023650 LS 152" Rollup, Full Height Front & Rear, FDLER NFPA 4.50 0.00 4.50 0063658 RS 152" Rollup, Full Height Front & Rear, FDLER NFPA 4.50 0.00 4.50 0083701 Compt, Rear, Rollup, 44.50" FF, 25.88" D NFPA 0.90 0.00 0.90 0536401 Gauges, Engine, Included With Pierce Pressure Controller NFPA 0.30 0.00 0.00 0536428 Gauge, Water Level, Pierce, In pressure Controller NFPA 1.23 0.00 0.00 0556360 Lights, Step, P25 LED 4lts, Pump Pnl Sw NFPA 1.00 0.00 0.00 0563675 Lights, Clearance/Marker/ID, Rear, Truck-Lite 33050R LED 7Lts NFPA 0.35 0.00 0.00 0564655 Lights, Rear Zn Lwr, Wln M6*C LED, Clear Lens, For Tail Lt Housing
NFPA 1.80 2.70 0.00
* UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 1 Electrical Analysis 6/10/2024
Bid #: 955
Santa Cruz FD 1500 gpm Pumper (similar to 38004) Sales Rep:

Organization:

Myers, Rich
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer: CITY OF SANTA CRUZ FIRE DEPT
Option: Pierce Command Zone, Advanced Electronics & Control System, Enforcer, WiFi CZT
Type: Multiplexed

11.86 Option Description Type* Minimum
Load
Intermittent
Load
Total
Connected
0568012 Air Dryer, Wabco System Saver 1200, Heater, 2010 NFPA 7.81 0.00 0.00 0603606 Cab Instruments, Ivory Gauges, Chrome Bezels, Enf MUX NFPA 1.26 0.00 0.00 0605126 Pump Shift, Air Mnl Override, Split Shaft, Interlocked, Waterous NFPA 1.00 0.00 0.00 0617802 Lights, Perimeter, TecNiq T10-LC00-1 15" LED NFPA 1.56 0.00 0.00 0617901 Lights, Perimeter Pump House, TecNiq T10-LC00-1 15" LED 2lts NFPA 0.80 0.00 0.00 0620054 Light, Directional/Marker, Intermediate, Weldon 9186-8580-29 LED 2lts
NFPA 0.10 0.90 0.00
0625210 Lights, Directional, Cab Front Side, Truck-Lite 19036Y LED, AXT/Enf
NFPA 0.12 0.00 0.00
0625650 Cab, Enforcer, 7000 NFPA 6.80 10.20 0.00
0625953 Light, Directional, Wln 600 Cmb, Cab Crn, Wrp Bzl Out HD Lts, Enf, Sab FR
NFPA 0.70 0.70 0.00
0626579 Lights, Perimeter Body, TecNiq T10-LC00-1 15" LED 2lts, Rear Step
NFPA 0.80 0.00 0.00
0626588 Lights, Perimeter Cab, TecNiq T10-LC00-1 15" LED 4Dr NFPA 1.60 0.00 0.00 0647647 Lights, Dome, FRP Dual LED 4 Lts NFPA 0.80 0.80 0.00 0653937 Flasher, Headlight Alternating NFPA 0.08 0.00 0.00 0662965 DEF Tank, 4.5 Gallon, DS Fill, Rear of Axle, Common Air Bottle Door
NFPA 0.60 11.40 0.00
0682498 Light Shield/Step 8", PS LED, P25 LED Stp Lt NFPA 3.85 0.00 0.00 0682503 Light Shield/Step 8", LED, P25 LED Stp Lt NFPA 4.00 0.00 0.00 0686562 Light, Rear Zone Up, Wln MCFLED2* LED NFPA 3.00 0.00 0.00 0721609 Controller, Pressure, Pierce LCD, Custom Chassis NFPA 1.70 0.00 0.00 0734071 Lights, Front Zone, Wln M6** M6** M6** M6** LED, Q Bzl, 4lts NFPA 3.60 5.40 0.00 0735474 Lights, Clearance/Marker/ID, Front, P25 LED 7 Lts, Saber FR/Enforcer
NFPA 0.35 0.00 0.00
0739224 Indicator Light @ Pump Panel, Throttle Ready, Incl w/Pressure Gov/Throttle,Green
NFPA 0.10 0.00 0.00
0745568 Indicator Light, Pump Panel, Ok To Pump, Green NFPA 0.10 0.00 0.00 0747228 Lights, Side Zone Lower, Wln M6**, M6**, M6**, 6Lts NFPA 5.40 8.10 0.00 0761022 Lights, Cargo/Dunnage, Amdor AY-LB-12HW020 Brkt NFPA 0.30 0.00 0.00 0767426 Cabinet, Rear Facing, RS, 22 W x 34 H x 26.75 D, Lap, Ext Acc, SFR/Enf
NFPA 0.30 0.30 0.00
0768474 Lights, Hose Bed, Below Alum Cvr, Amdor AY-LB-12HW040, 40" LED 4lts
NFPA 2.40 0.00 0.00
0771805 Cabinet, Rear Facing, LS, 23 W x 34 H x 26.75 D, Lap, Ext Acc, SFR/Enf
NFPA 0.68 0.68 0.00
0773930 Lightbar, Wln, Freedom IV-Q, 92",
RRRWRWRsr_Opt_srRWRWRRR
NFPA 6.48 5.16 9.92
0783153 Headlights, Rect LED, JW Spkr Evo 2, AXT/DCF/Enf/Imp/Sab/Vel NFPA 4.20 4.20 0.00 0784767 Load Manager/Sequencer, MUX NFPA 0.56 0.56 0.00 0791493 Light, Traffic Directing, Wln TAM65 36" Long LED NFPA 1.26 2.52 0.00 0804514 Lights, Tail, Wln M62BTT* Red Stop/Tail & M62T* Amber Dir Arw For Hsg
NFPA 0.83 2.49 0.00
0808497 Engine, Cummins X15, 565 hp, 1850 lb-ft, W/OBD, EPA 2027, Enforcer
NFPA 6.00 0.00 0.00
0814201 Vehicle Information Center, 7" Color Display, Touchscreen, MUX, CL714
NFPA 1.20 0.00 0.00
0819956 Cabinet, Fwd Fcng, Ctr, 32 W x 40 H x 28 D, Web, SFR/Enf NFPA 0.40 0.40 0.00 0887546 Trans, Allison 6th Gen, 4000 EVS P, w/Prognostics, Imp/Vel/SFR/Enf
NFPA 2.00 2.00 0.00
0889577 Bracket, License Plate & Light, P25 LED, Stainless Brkt NFPA 0.07 0.00 0.00 0892638 Lights, Cab & Crw Cab Acs Stps, P25, LED w/Bezel, 6lts NFPA 1.00 0.00 0.00 0892704 Lights, Walk Surf, 8-P25 LED, Hose Bed Cover, Overall Height Restrictions
NFPA 0.07 0.00 0.00
0647728 Alternator, 430 amp, Delco Remy 55SI S 0.00 0.00 0.00 Load Totals: 94.86 786.15 393.45
Note: Minimum Continous Load is in "Blocking Right of Way" mode.(Reference current edition of NFPA 1901) Note: Intermittent Load items are not factored in on any alternator load comparisons. These items are included on the report for reference only and should be looked at as amp draw exclusion items. (Reference current edition of NFPA 1901) Note: Total Connected Load "Demand" represents Total Connected Load minus any Load Managed items * UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 2 Electrical Analysis 6/10/2024
Bid #: 955
Santa Cruz FD 1500 gpm Pumper (similar to 38004) Sales Rep:

Organization:

Myers, Rich
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer: CITY OF SANTA CRUZ FIRE DEPT
Option: Pierce Command Zone, Advanced Electronics & Control System, Enforcer, WiFi CZT
Type: Multiplexed

11.87 Minimum Continuous Load
Supply: 253.00
Demand: 94.86
Variance: 158.14
Total Connected Load
Supply: 369.00
Demand: 362.31
Variance: 6.69
Alternator Output at Idle: 253.00 Alternator Output at Governed Speed: 369.00 * UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 3 Electrical Analysis 6/10/2024
Bid #: 955
Santa Cruz FD 1500 gpm Pumper (similar to 38004) Sales Rep:

Organization:

Myers, Rich
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer: CITY OF SANTA CRUZ FIRE DEPT
Option: Pierce Command Zone, Advanced Electronics & Control System, Enforcer, WiFi CZT
Type: Multiplexed

11.88 Turning Performance Analysis
Bid Number: 955 Chassis: Enforcer Chassis
Department: CITY OF SANTA CRUZ FIRE DEPT Body: Pumper, Medium, Aluminum, 2nd Gen Parameters:
*Inside Cramp Angle: 45°
Axle Track: 82.92 in.

Wheel Offset: 5.25 in.

Tread Width: 16.3 in.

Chassis Overhang: 65.95 in.

Additional Bumper Depth: 16 in.

Front Overhang: 81.95 in.

Wheelbase: 187.5 in.

Calculated Turning Radii:

Inside Turn: 14 ft. 6 in.

Curb to curb: 28 ft. 6 in.

Wall to wall: 32 ft. 7 in.

Notes:
*Actual Inside cramp angle may be less than shown.

Curb to Curb turning radius calculated for 9.00 inch curb. 06/10/2024
Category Option Description
Axle, Front, Custom 0629940 Axle, Front, Oshkosh TAK-4, Non Drive, 22,800 lb, Enforcer Bumpers 0630342 Bumper, 16" Extended, Steel Painted, Saber FR/Enforcer Wheels, Front 0604672 Wheels, Front, Accuride, 22.50" x 12.25", Steel, Hub Pilot Tires, Front 0899438 Tires, Front, Goodyear, Armor MAX MSA, 425/65R22.50, 20 ply

11.89 Definitions:

Inside CrampAngle Maximum turning angle of the front inside fire.

Axle Track King-pin to King-pin distance of front axle.

Wheel Offset Offset from the center line of the wheel to the King-pin.

Tread Width Width of the tire tread.

Chassis Overhang Distance of the center line of the front axle to the front edge of the cab. This does not include the bumper depth.

Additional Bumper Wheel Depth that the bumper assembly adds to the front overhang.

Wheelbase Distance between the center lines of the vehicles front and rear axles.

Inside Turning Radius Radius of the smallest circle around which the vehicle can turn.

Curb to Curb Turning Radius Radius of the smallest circle around which the vehicle's tires can turn. This measures assumes a curb height of 9 inches.

Wall to Wall Turning Radius Radius of the smallest circle around which the vehicle's tires can turn. This measures takes into account any front overhang due to chassis , bumper extensions and or aerial devices.

11.90 JROGHQVWDWHĆUHFRP

PRODUCT

WARRANTIES
Exhibit “C”
4 11.91
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0008

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

No specific exclusions apply
Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:

One (1) Year Material and Workmanship
Basic Apparatus
Twelve (12) months. Warranty Period
Ends After:

The date the apparatus is placed in service, or 60 days from the original buyer invoice date, whichever comes first. Warranty Begins:

Portions of the apparatus manufactured by Pierce shall be free from defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

11.92 Cummins Warranty
Worldwide
Fire Apparatus/Crash Trucks

11.93 Coverage
Products Warranted
This Warranty applies to new diesel Engines sold by
Cummins and delivered to the first user on or after
April 1, 2007, that are used in fire apparatus truck and crash truck* applications Worldwide.

Base Engine Warranty
The Base Engine Warranty covers any failures of the
Engine which result, under normal use and service,
from a defect in material or factory workmanship
(Warrantable Failure). This Coverage begins with the
sale of the Engine by Cummins and ends five years or
100,000 miles (160,935 kilometers), whichever occurs
first, after the date of delivery of the Engine to the first user.

Engine aftertreatment components included in the
Cummins Critical Parts List (CPL) and marked with a
Cummins part number are covered under Base Engine
Warranty.

Additional Coverage is outlined in the Emission
Warranty section.

These Warranties are made to all Owners in the
chain of distribution and Coverage continues to all
subsequent Owners until the end of the periods of
Coverage.

Cummins
Responsibilities
Cummins will pay for all parts and labor needed to
repair the damage to the Engine resulting from a
Warrantable Failure.

Cummins will pay for the lubricating oil, antifreeze,
filter elements, belts, hoses and other maintenance
items that are not reusable due to the Warrantable
Failure.

Cummins will pay for reasonable labor costs for
Engine removal and reinstallation when necessary to
repair a Warrantable Failure.

Cummins will pay reasonable costs for towing a
vehicle disabled by a Warrantable Failure to the
nearest authorized repair location. In lieu of the towing expense, Cummins will pay reasonable costs for
mechanics to travel to and from the location of the
vehicle, including meals, mileage and lodging when
the repair is performed at the site of the failure.

Owner
Responsibilities
Owner is responsible for the operation and
maintenance of the Engine as specified in Cummins
Operation and Maintenance Manuals. Owner is also
responsible for providing proof that all recommended
maintenance has been performed.

Before the expiration of the applicable Warranty,
Owner must notify a Cummins distributor, authorized
dealer or other repair location approved by Cummins
of any Warrantable Failure and make the Engine
available for repair by such facility. Except for Engines disabled by a Warrantable Failure, Owner must also
deliver the Engine to the repair facility.

Service locations are listed on the Cummins Worldwide
Service Locator at cummins.com.

Owner is responsible for the cost of lubricating oil,
antifreeze, filter elements and other maintenance items provided during Warranty repairs unless such items
are not reusable due to the Warrantable Failure.

Owner is responsible for communication expenses,
meals, lodging and similar costs incurred as a result of a Warrantable Failure.

Owner is responsible for non-Engine repairs and for
‘‘downtime’’ expenses, cargo damage, fines, all
applicable taxes, all business costs and other losses
resulting from a Warrantable Failure.

Owner is responsible for a $100 (U.S. Dollars)
deductible per each service visit under this plan in the 3rd, 4th and 5th years of Base Engine Warranty. The
deductible will not be charged during the first 2 years of the Base Engine Warranty.

Limitations
Cummins is not responsible for failures or damage
resulting from what Cummins determines to be abuse
or neglect, including, but not limited to: operation
without adequate coolants or lubricants; overfueling;
overspeeding; lack of maintenance of lubricating,
cooling or intake systems; improper storage, starting,
warm-up, run-in or shutdown practices; unauthorized
modifications of the Engine.

Any unauthorized modifications to the aftertreatment
could negatively effect emissions certification and void Warranty.

Cummins is also not responsible for failures caused by
incorrect oil, fuel or diesel exhaust fluid or by water, dirt or other contaminants in the fuel, oil or diesel

11.94 exhaust fluid.

This Warranty does not apply to accessories supplied
by Cummins which bear the name of another
company. Such non-warranted accessories include, but
are not limited to: alternators, starters, fans, air
conditioning compressors, clutches, filters,
transmissions, torque converters, vacuum pumps,
power steering pumps, fan drives and air compressors.

Cummins branded alternators and starters are covered
for the first two years from the date of delivery of the Engine to the first user, or the expiration of the Base Engine Warranty, whichever occurs first.

Failures resulting in excessive oil consumption are not covered beyond the duration of the Coverage or
100,000 miles (160,935 kilometers) or 7,000 hours from
the date of delivery of the Engine to the first user,
whichever of the three occurs first. Before a claim for excessive oil consumption will be considered, Owner
must submit adequate documentation to show that
consumption exceeds Cummins published standards.

Failures of belts and hoses supplied by Cummins are
not covered beyond the first year from the date of
delivery of the Engine to the first user or the duration of the Warranty, whichever occurs first.

Parts used to repair a Warrantable Failure may be new
Cummins parts, Cummins approved rebuilt parts or
repaired parts. Cummins is not responsible for failures resulting from the use of parts not approved by
Cummins.

A new Cummins or Cummins approved rebuilt part
used to repair a Warrantable Failure assumes the
identity of the part it replaced and is entitled to the remaining Coverage hereunder.

Cummins Inc. reserves the right to interrogate
Electronic Control Module (ECM) data for purposes of
failure analysis.

CUMMINS DOES NOT COVER WEAR OR WEAROUT
OF COVERED PARTS.

CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.

THIS WARRANTY AND THE EMISSION WARRANTY

SET FORTH HEREINAFTER ARE THE SOLE

WARRANTIES MADE BY CUMMINS IN REGARD TO
THESE ENGINES. CUMMINS MAKES NO OTHER

WARRANTIES, EXPRESS OR IMPLIED, OR OF

MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE.

This Warranty gives you specific legal rights, and you
may also have other rights which vary from state to
state.

Emission
Warranty
Products Warranted
This Emission Warranty applies to new Engines
marketed by Cummins that are used in the United
States** in vehicles designed for transporting persons
or property on a street or highway. This Warranty
applies to Engines delivered to the first user on or after September 1, 1992.

Coverage
Cummins warrants to the first user and each
subsequent purchaser that the Engine is designed,
built and equipped so as to conform at the time of sale by Cummins with all U.S. federal emission regulations
applicable at the time of manufacture and that it is free from defects in material or factory workmanship which
would cause it not to meet these regulations within the longer of the following periods: (A) Five years or
100,000 miles (160,935 kilometers) of operation,
whichever occurs first, as measured from the date of
delivery of the Engine to the first user or (B) The Base Engine Warranty.

If the vehicle in which the Engine is installed is
registered in the state of California, a separate
California Emission Warranty also applies.

Limitations
Failures, other than those resulting from defects in
material or factory workmanship, are not covered by
this Warranty.

Cummins is not responsible for failures or damage
resulting from what Cummins determines to be abuse
or neglect, including, but not limited to: operation
without adequate coolants or lubricants; overfueling;
overspeeding; lack of maintenance of lubricating,
cooling or intake systems; improper storage, starting,
warm-up, run-in or shutdown practices; unauthorized
modifications of the Engine.

Any unauthorized modifications to the aftertreatment
could negatively effect emissions certification and void Warranty.

Cummins is also not responsible for failures caused by
incorrect oil, fuel or diesel exhaust fluid or by water, dirt or other contaminants in the fuel, oil or diesel
exhaust fluid.

Cummins is not responsible for non-Engine repairs,
‘‘downtime’’ expenses, cargo damage, fines, all
applicable taxes, all business costs or other losses
resulting from a Warrantable Failure.

11.95 Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.

Bulletin 3381161
Printed in U.S.A. Rev. 08/09
©2001 Cummins Inc.

CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.
* Airport operated crash trucks and fire department
operated trucks employed to respond to fires,
hazardous material releases, rescue and other
emergency-type situations.
** United States includes American Samoa, the
Commonwealth of Northern Mariana Islands, Guam,
Puerto Rico and the U.S. Virgin Islands.

Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.

Bulletin 3381161
Printed in U.S.A. Rev. 08/09
2001 Cummins Inc.

11.96 11.97

11.98 11.99

11.100
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0013

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This warranty does not apply to damage caused by corrosion.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:

Lifetime Fifty (50) Year Structural Integrity
Custom Chassis Frame
Fifty (50) Years
(Expected Life of Apparatus)
Warranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

Custom chassis frame rail manufactured by Pierce shall be free from defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

11.101
This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty excludes brake pads, brake rotors, seal boots and shock absorbers.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Three (3) Years
-or30,000 Miles
Warranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 12/16/2013 WA0050
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

Fire and Rescue Apparatus
Coverage:

Three (3) Year Material and Workmanship
TAK-4 Independent Front Suspension
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The TAK-4 Front Independent Suspension and Steering
Gears shall be free from defects in material and
workmanship.

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

11.102
Fire and Rescue Apparatus
Coverage:

SUPPLIER
Limited Warranty Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The Meritor axle shall be covered by Meritor as indicated in the attached Meritor warranty coverage description

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the purchaser who first puts the product in service ("Buyer"):
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

The exclusions listed in the attached Meritor warranty
description shall apply.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Five (5) Years Warranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 6/29/2020 WA0384
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

11.103

CUMMINS-MERITOR

COMMERCIAL

VEHICLE SYSTEMS

WARRANTY

COVERAGE FOR THE

UNITED STATES AND CANADA
MODEL YEAR 2024 VEHICLES

11.104
2 WARRANTY INFORMATION

TABLE OF CONTENTS
EFFECTIVE MODEL YEAR 2024 VEHICLES
Linehaul.......................................................................................................3 General Service ...........................................................................................6 Heavy Service/Specialty Vehicle ..................................................................9 Fire and Emergency................................................................................... 12 Transit Bus ................................................................................................ 14 Off-highway Service................................................................................... 15 Terms and Conditions................................................................................ 17 How to Read Warranty Coverage
Number of Years Mileage (in thousands)
Unl = Unlimited
P = Parts Only
P&L = Parts and Labor
Notice:

Models or components that are approved for use by Cummins-Meritor’s vocational guidelines contained in Cummins-Meritor publication TP-9441 for axles, SP-8320 for trailer axles and TP-12126 for drivelines, or any other products that have an application approval completed with Cummins-Meritor which are not specifically listed, are warranted for one year, unlimited miles, parts only (1/Unl/P).

Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles, parts only (1/Unl/P).

Advantage Program
Purchasing additional coverage on select components will continue to safeguard your investment against major repair costs after the initial base coverage expires. You can find out more about the Advantage Program by visiting meritor.com or by contacting Cummins-Meritor at 866-OnTrac1 (866-668-7221).

11.105
3 Linehaul Vehicles
Auto Hauler1
Bulk Hauler1
Chip Hauler1,2
Doubles
Flatbed
General Freight
Grain Hauler1
Livestock Hauler
Moving Van
Pipe Hauler
Refrigerated Freight
Tanker1
Triples
1 Cummins-Meritor classifies these vehicle types as high center of gravity, which require special axle housing considerations. 2 Chip Hauler vehicles require specific axle models listed below and Linehaul condition to be eligible for Linehaul warranty consideration.

Linehaul Typically Is:

High mileage operation (over 60,000 miles/year)
Greater than 30 miles between starts and stops
Maximum grades of 12%
Well maintained highways of concrete or asphalt construction (100% on-road)
Category A job sites, terminals, docks and transfer sites (defined as pavement, concrete or maintained and hard packed gravel).

Note:Category B job sites, terminals, docks, transfer sites (defined as loose or unmaintained sand, dirt or gravel; landfill; farm field; mud; or other similar surfaces) are NOT approved for certain linehaul axle models.

Front Non-Drive Steer Axles – 5/750/P&L
FD-965
FF-941
FF-942
FF-943
FF-944
FF-961
FF-966
FF-967
FG-941
FG-943
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122A-N
MFS-12-122B-N
MFS-12-122C-N
MFS-12E-122A-N
MFS-12E-122B-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12-132C-N
MFS-12E-132B-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12E-143A-N
MFS-12-144A-N
MFS-13-122A-N
MFS-13-122B-N
MFS-13-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-13B-122B-N
MFS-13B-122C-N
MFS-13B-132B-N
MFS-13B-132C-N
MFS-14-122A-N
MFS-14-122B-N
MFS-14F-122B-N
MFS-14G-122B-N
MFS-14-122C-N
MFS-14F-122C-N
MFS-14G-122C-N
MFS-14-124A-N
MFS-14-132B-N
MFS-14F-132B-N
MFS-14G-132B-N
MFS-14-132C-N
MFS-14F-132C-N
MFS-14G-132C-N
MFS-14-142B-N
MFS-14F-142B-N
MFS-14G-142B-N
MFS-14-142C-N
MFS-14F-142C-N
MFS-14G-142C-N
MFS-14-143A-N
MFS-14-144A-N
Rear Drive Single Axles – 5/750/P&L
MS-19-14X
RS-21-160
MS-23-17H1,2
MS-23-17X2
RS-23-160
RS-23-161
RS-23-185
RS-23-186
Coverage under Cummins-Meritor’s warranty require that
the application of products be properly approved pursuant to OEM and Cummins-Meritor approvals. Refer to TP-9441
for axles, SP-8320 for trailer axles, TP-12126 for drivelines and/or contact Cummins-Meritor regarding specific
application approval questions on any product line.

LINEHAUL

WARRANTY INFORMATION
Vocational Definition of Linehaul
Long distance hauling of food, goods and finished materials Not included are raw ferrous materials, minerals (except oil), sand, gravel, stone, rocks, topsoil, waste or logs Linehaul includes turnpike and hub & spoke
1 Not approved for use in any Category B job sites, terminals, docks or transfer sites. 2 Recommend 11 mm minimum wall thickness for these models used in combination with high center of gravity vehicles and trailing arm suspensions or vehicles operating mainly in Canada.

11.106
4 Trailer Axles1
Beam and Brackets 5/500/P, 1/100/L
TPX3000 Axle Series2 10/Unl/P, 1/Unl/L
Wheel End Systems3
Standard System4 1/100/P&L
AxlePak5 5/Unl/P&L
AxlePak75 7/Unl/P&L
1 For brake components and ABS coverage, refer to appropriate product warranties. 2 Structural components only excluding spindle wear. Spindle wear is 5/Unl/P, 1/Unl/L. 3 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage. 4 When installed by Cummins-Meritor. 5
When specified with AxlePak7 wheel end system, coverage on Meritor Tire Inflation System (MTIS) thru-tee and stator is 7/Unl/P, 1/Unl/L.

TAG/Pusher Axles1
TQ, TR Beam and Brackets 5/750/P&L
1 For brake components and ABS coverage, refer to appropriate product warranties.

Trailer Mechanical Suspension
Systems1
IMS40 (Integrated Mechanical Suspension – Tandem)2 1/Unl/P&L IMS20 (Integrated Mechanical Suspension – Single)2 1/Unl/P&L 1 For axle coverage, refer to appropriate product warranties. 2 All other suspension components refer to appropriate manufacturer’s warranty.

Trailer Air Suspension Systems
MPA40 (Tandem Axle Parallelogram)1
Major Structural Components 5/500/P, 1/100/L
Curbing Damage Warranty2 5/500/P, 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs 2/200/P, 1/100/L
Bushings 5/Unl/P, 3/Unl/L
PinLoc Air Controls 1/100/P&L
PinLoc Actuator 3/300/P&L
MPA20 (Single Axle Parallelogram)
Major Structural Components 5/500/P, 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs 2/200/P, 1/100/L
Bushings 5/Unl/P, 3/Unl/L
MTA and MTA-Tec6 Trailing Arm Suspension System
Major Structural Components 5/500/P, 1/100/L
Height Control Valve 1/100/P&L
Air Springs 2/200/P, 1/100/L
Bushings 5/500/P, 3/300/L
Shock Absorbers 2/200/P&L
Lift Kit System 1/100/P&L
1 Fastener torque coverage is limited to 2/Unl/P&L when torqued by CumminsMeritor (For axle and ABS coverage, refer to appropriate product warranties.) 2 “Curbing damage” is defined as deformation (bending, buckling or breakage), caused by sudden impact with a curb or similar fixed object. Damage to the RideSentry slider box (the suspension sliding sub-frame consisting of the frame rails, cross-members and central A-frame assembly), caused by accidental trailer impact with a curb or similar fixed object, is eligible for warranty coverage. Damage to other components or resulting from collision with another vehicle, rollover or fire is not covered under this provision. Warranty is not transferable to another trailer VIN and coverage does not apply if the trailer is deemed to be a total loss, scrapped or otherwise not salvageable.

LINEHAUL

WARRANTY INFORMATION
Rear Drive Tandem/Tridem Axles – 5/750/P&L
RT-40-160/P1,2
RT-46-160/P1,2
RT-46-164/P1,2
RZ-1662
RT-50-160/P1,2
MA-40-165
MA-40-17H3
RZ-188
MA-40-175
MT-34-14X/P4
MT-40-14T/P
MT-40-14X/P4
MT-40-14X/P4
MT-40-14H/E3,4
1 These models required for Chip Hauler and Linehaul warranty consideration. 2 Each vehicle must have a Request for Application Recommendation (RAR) approved by Cummins-Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details. 3 Not approved for use in any Category B job sites, terminals, docks or transfer sites. 4 Recommend 11 mm minimum wall thickness for these models used in combination with high center of gravity vehicles and trailing arm suspensions or vehicles operating mainly in Canada.

11.107
5 LINEHAUL

WARRANTY INFORMATION
Brake Components
Cam Q Series Trailer Brakes 5/500/P, 1/100/L
Q+ Drum Brake™1 5/500/P, 1/Unl/P&L
ASA 5/500/P, 1/Unl/P&L
Hubs/Cast Drums and Other Wheel-End Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
STEELite X30 Drum Brake™2 12-Years or Wearable Life/P
EX+ L and EX+LS Air Disc Brake™3 5/500/P, 1/Unl/L
EX+L Air Disc Brake Extended Standard Warranty3,4 5/500/P&L 1 For Trailer only, 3/300/P against rust jacking when equipped with Platinum Shield III. 2
Based on stamped wear diameter max. 3
Warranty coverage for boots, seals, caps, bushings and pins is 2/200/P.

Warranty coverage for pads is 1/100/P. 4
Applies only to calipers using friction: MA9300 (EX225LXXXCGXXX).

Drivelines
RPL 5/500/P, 1/Unl/P&L
MXL 3/350/P, 1/Unl/P&L
92N 1/Unl/P
Meritor Tire Inflation System
(MTIS)
MTIS Components 5/Unl/P, 1/Unl/L

11.108
6 General Service Vehicles
Auto Hauler
Beverage Truck
Bulk Hauler
Chip Hauler
Cross Country Coach
Flatbed
Front Engine Commercial
Chassis
Front Engine Integral Coach
General Freight
Grain Hauler
Intercity Coach
Intermodal Chassis
Livestock Hauler
Meat Packer
Moving Van
Municipal Truck
Newspaper Delivery
Pick-Up and Delivery
Pipe Hauler
Platform Auto Hauler
Rear Engine Integral Coach
Recreational Vehicles
Refrigerated Freight
School Bus
Stake Truck
Tanker
Tanker Trailer
Tour Bus
Wrecker
General Service Typically Is:

Typically, moderate mileage operation (less than 60,000 miles/year) An average of 3 to 30 miles between starts and stops
Maximum grades of 12%
Generally, on-road service (less than 10% off-road allowed) Category A job sites, terminals, docks and transfer sites (defined as pavement, concrete or maintained and hard packed gravel) or Category B job sites, terminals, docks and transfer sites (defined as loose or unmaintained sand, dirt or gravel; landfill; farm field; mud, or other similar surfaces)
Front Non-Drive Steer Axles – 2/Unl/P&L
FD-965
FF-941
FF-942
FF-943
FF-944
FF-946
FF-961
FF-966
FF-967
FG-941
FH-941
FH-9461
FL-941
FL-943
MFS-6-151A-N
MFS-6-153B-N
MFS-6-162B-N
MFS-6-153C-N
MFS-6-162C-N
MFS-7-113C-N
MFS-7-153C-N
MFS-7-163C-N
MFS-8-113B-N
MFS-8-143A-N
MFS-8-153B-N
MFS-8-163B-N
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122A-N
MFS-12E-122A-N
MFS-12-122B-N
MFS-12E-122B-N
MFS-12-122C-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12E-132B-N
MFS-12-132C-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12-144A-N
MFS-12E-143A-N
MFS-13-122A-N
MFS-13-122B-N
MFS-13B-122B-N
MFS-13-122C-N
MFS-13B-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13B-132B-N
MFS-13B-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-14-122A-N
MFS-14-122B-N
MFS-14F-122B-N
MFS-14G-122B-N
MFS-14-122C-N
MFS-14F-122C-N
MFS-14G-122C-N
MFS-14-124A-N
MFS-14-132B-N
MFS-14F-132B-N
MFS-14G-132B-N
MFS-14-132C-N
MFS-14F-132C-N
MFS-14G-132C-N
MFS-14-142B-N
MFS-14F-142B-N
MFS-14G-142B-N
MFS-14-142C-N
MFS-14F-142C-N
MFS-14G-142C-N
MFS-14-143A-N
MFS-14-144A-N
MFS-16-122A-N
MFS-16-133A-N
MFS-16-135A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
1 Can also be used with reduced steer angles in tag position in Coach applications.

GENERAL SERVICE

WARRANTY INFORMATION
Coverage under Cummins-Meritor’s warranty require that
the application of products be properly approved pursuant to OEM and Cummins-Meritor approvals. Refer to TP-9441
for axles, SP-8320 for trailer axles, TP-12126 for drivelines and/or contact Cummins-Meritor regarding specific
application approval questions on any product line.

11.109
7 GENERAL SERVICE

WARRANTY INFORMATION
Rear Drive Tandem/Tridem Axles – 2/Unl/P&L
MT-34-14X/P
MT-40-14T/P
MT-40-14X/P
MT-44-14X/P
RT-46-169
MT-52-616
RT-52-1851
MT-58-616
RT-58-1851
MT-70-380
RZ-188
1 Each vehicle must have a Request for Application Recommendation (RAR) approved by Cummins-Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details.

Rear Drive Tandem/Tridem – 3/Unl/P&L
RT-40-160/P RT-46-160/P RT-46-164/P RT-50-160/P RZ-166
Rear Drive Axles – 1/Unl/P&L
RND-14H RND-16A
PTO – 1/Unl/P&L
MPT-170
MPT-180
MPT-185
MPT-309
MPT-500
MPT-518
MPT-1702
Brake Components
Cam Q Series Trailer Brakes1 3/Unl/P, 1/Unl/L
Cam P2 2/200/P
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
Q+ Drum Brake™1,2 2/200/P&L
ASA 3/Unl/P
ASA2 2/200/P
Hubs/Cast Drums and Other Wheel-End Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
STEELite X30 Drum Brake™3 12-Years or Wearable Life/P
EX+ Air Disc Brake™4 2/Unl/P&L
1 For Trailer only, 3/300/P against rust jacking when equipped with Platinum Shield III or Chassis Protect. 2
Applies to Tour Bus and Cross Country Coach only. 3
Based on stamped wear diameter max. 4
Warranty coverage for boots, seals, caps, bushings and pins is 2/200/P.

Warranty coverage for pads is 1/100/P.

Drivelines
RPL 4/400/P, 1/Unl/P&L
MXL 3/350/P, 1/Unl/P&L
92N 1/Unl/P
Rear Drive Single Axles – 2/Unl/P&L
MS-17-13X
MS-17-14X
MS-19-13X
MS-19-14X
MS-21-13X
MS-21-14X
MS-23-17X
RS-21-160
RC-23-160
RC-23-161
RC-23-1621
RC-23-1651
RS-23-160
RS-23-161
RS-23-185
RS-23-186
RS-24-160
RC-25-160
RS-26-185
MS-26-616
MS-26-616-SP
RS-30-185
MS-30-616
MS-30-616-SP
RS-35-380
1 3/Unl/P&L if PreSet by Cummins-Meritor.

11.110
8 Trailer Axles1
Beam and Brackets2 5/Unl/P, 1/Unl/L
TPX4000 Axle Series3 10/Unl/P, 1/Unl/L
Wheel End Systems4
Standard System5 1/Unl/P&L
AxlePak5 5/Unl/P&L
AxlePak76 7/Unl/P&L
AxlePak107 10/Unl/P&L
1 For brake components and ABS coverage, refer to appropriate product warranties.
2 9000 Series is 3/Unl/P, 1/Unl/L 3 Structural components only excluding spindle wear. Spindle wear 5/Unl/P, 1/Unl/L. 4 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage. 5 When installed by Cummins-Meritor. 6
When specified with AxlePak7 wheel end system, coverage on Meritor Tire Inflation System (MTIS) thru-tee and stator is 7/Unl/P, 1/Unl/L. 7 AxlePak10 is limited to Intermodal Chassis applications equipped with TPX4000 series axles.

TAG/Pusher Axles1
TQ, TR Beam and Brackets 3/Unl/P, 1/Unl/L
MC14002, MC16003, FH9462 2/Unl/P&L
1 For brake components coverage, refer to appropriate product warranties. 2 3/Unl/P&L if sold with PreSet by Cummins-Meritor.

Meritor Tire Inflation System
(MTIS)
MTIS Components 5/Unl/P, 1/Unl/L
Trailer Mechanical Suspension
Systems1
IMS40 (Integrated Mechanical Suspension – Tandem)2 1/Unl/P&L IMS20 (Integrated Mechanical Suspension – Single)2 1/Unl/P&L 1 For axle coverage, refer to appropriate product warranties. 2 All other suspension components refer to appropriate manufacturer’s warranty.

Trailer Air Suspension Systems1
MPA40 (Tandem Axle Parallelogram)2
Major Structural Components 5/Unl/P, 1/Unl/L
Curbing Damage Warranty3 5/500/P, 1/100/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P, 1/Unl/L
Bushings 5/P, 3/L
PinLoc Air Controls 1/Unl/P&L
PinLoc Actuator 3/Unl/P&L
MPA20 (Single Axle Parallelogram)
Major Structural Components 5/Unl/P, 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs and Rebound Straps 2/Unl/P, 1/Unl/L
Bushings 5/P, 3/L
MTA and MTA-Tec6 Trailing Arm Suspension System
Major Structural Components 5/Unl/P, 1/Unl/L
Height Control Valve 1/Unl/P&L
Air Springs 2/Unl/P, 1/Unl/L
Bushings4 5/Unl/P, 3/Unl/L
Shock Absorbers 2/Unl/P&L
Lift Kit System 1/Unl/P&L
1 For axle coverage, refer to appropriate product warranties. 2 Fastener torque coverage is limited to 2/Unl/P&L when torqued by CumminsMeritor. 3 “Curbing damage” is defined as deformation (bending, buckling or breakage), caused by sudden impact with a curb or similar fixed object. Damage to the RideSentry slider box (the suspension sliding sub-frame, consisting of the frame rails, cross-members and central A-frame assembly), caused by accidental trailer impact with a curb or similar fixed object, is eligible for warranty coverage. Damage to other components or damage resulting from collision with another vehicle, rollover or fire is not covered under this provision. Warranty is not transferable to another trailer VIN and coverage does not apply if the trailer is deemed to be a total loss, scrapped or otherwise not salvageable. 4 Raw wood applications 3/Unl/P, 1/Unl/L

GENERAL SERVICE

WARRANTY INFORMATION

11.111
9 Heavy Service/Specialty Vehicles
Airport Rescue Fire
Fighting (ARFF)
Airport Shuttle1
Asphalt Truck
Block Truck
Bottom Dump Trailer
Combination
Cementing Vehicle
Commercial Pick-Up
Concrete Pumper
Construction Material Hauler
Mixer
Demolition
Drill Rig
Dump
Equipment Hauling
Flatbed Trailer Hauler
Flatbed Truck
Fracturing Truck
Front Loader
Geophysical Exploration
Hopper Trailer Combinations
Landscaping Truck
Liquid Waste Hauler
Log Hauling
Lowboy
Michigan Special Gravel
Train
Michigan Special Log Hauler
Michigan Special Steel
Hauler
Michigan Special Waste
Vehicle
Municipal Dump
Rear Loader (Refuse)
Recycling Truck
Residential Pick-Up (Refuse)
Rigging Truck
Roll-Off
Scrap Truck
Semi-End Dump
Sewer/Septic Vacuum
Shuttle Bus1
Side Loader
Snowplow/Snowblower
Steel Hauling
Tanker
Tank Truck
Tractors with Pole Trailers
Tractor/Trailer with Jeeps
Transfer Dump
Transfer Vehicle
Utility Truck
Winch Truck
1 Commercial chassis only
Heavy Service/Specialty Vehicle
Typically Is:

Moderate mileage operation (less than 60,000 miles per year) On/off-road vocations (10% or more off-road)
Moderate to frequent stops/starts (up to 10 stops per mile) An average of three (3) miles between starting and stopping Front Non-Drive Steer Axles – 2/Unl/P&L
FD-965
FF-941
FF-942
FF-943
FF-944
FF-946
FF-961
FF-966
FF-967
FG-941
FG-943
FH-941
FH-946
FL-941
FL-943
MFS-6-151A-N
MFS-6-153B
MFS-6-162B
MFS-6-162C
MFS-7-113C-N
MFS-7-153C-N
MFS-7-163C-N
MFS-8-113B-N
MFS-8-153B-N
MFS-8-163B-N
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122
MFS-12E-122
MFS-12-122B-N
MFS-12E-122B-N
MFS-12-122C-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12E-132B-N
MFS-12-132C-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12-144A-N
MFS-12-155
MFS-13-122
MFS-13-122B-N
MFS-13B-122B-N
MFS-13-122C-N
MFS-13B-122C-N
MFS-13-132B-N
MFS-13B-132B-N
MFS-13-132C-N
MFS-13B-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-13-155
MFS-14-122
MFS-14-122B-N
MFS-14F-122B-N
MFS-14G-122B-N
MFS-14-122C-N
MFS-14F-122C-N
MFS-14G-122C-N
MFS-14-124A-N
MFS-14-132B-N
MFS-14F-132B-N
MFS-14G-132B-N
MFS-14-132C-N
MFS-14F-132C-N
MFS-14G-132C-N
MFS-14-142B-N
MFS-14F-142B-N
MFS-14G-142B-N
MFS-14-142C-N
MFS-14F-142C-N
MFS-14G-142C-N
MFS-14-143A-N
MFS-14-144A-N
MFS-16-122A-N
MFS-16-133A-N
MFS-16-135A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-192A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
RF-16-145
RF-21-160

HEAVY SERVICE/SPECIALTY VEHICLE

WARRANTY INFORMATION
Coverage under Cummins-Meritor’s warranty require that
the application of products be properly approved pursuant to OEM and Cummins-Meritor approvals. Refer to TP-9441
for axles, SP-8320 for trailer axles, TP-12126 for drivelines and/or contact Cummins-Meritor regarding specific
application approval questions on any product line.

11.112
10 Rear Drive Axles – 2/Unl/P&L
MS-17-14X
MS-19-14X
MS-21-14X
RS-21-160
RC-23-160
RH-23-160
RS-23-160
RC-23-161
RS-23-161
RS-23-185
RS-23-186/380
RS-24-160
RC-25-160
RS-25-160
MS-26-616
MS-26-616-SP
RS-26-185/380
RC-26-633
MS-30-616
MS-30-616-SP
RS-30-185/380
MS-35-380
RS-38-380
MT-58-616
MT-58-616-SP
Rear Drive Axles – 1/Unl/P&L
RND-14H RND-16A
Rear Drive Tandem/Tridem Axles – 2/Unl/P&L
MT-34-14X/P
MT-40-14T/P
MT-40-14X/P
MT-44-14X/P
RT-46-169
RT-58-160
MT-52-616
MT-52-616-SP
RT-52-185/3801,2
MT-58-616
MT-58-616-SP
RT-58-185/3801,2
RT-70-380
MT-70-380
RZ-188
1 Axle model designated will vary according to options and variations specified on these axles. Contact Cummins-Meritor Axle Applications Engineering for details. 2 Each vehicle must have a Request for Application Recommendation (RAR) approved by Cummins-Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details.

Rear Drive Tandem/Tridem – 3/Unl/P&L
RT-40-160/P/A3 RT-46-160/P/A1,3 RT-46-164/P2,3 RT-50-160/P/A3 RZ-166 1 U.S. only. Canadian warranty = 1/Unl/P for combination vehicles only. 2 Axle model designated will vary according to options and variations specified on these axles. Contact Cummins-Meritor Axle Applications Engineering for details. 3 Each vehicle must have a Request for Application Recommendation (RAR) approved by Cummins-Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details.

Front Drive Steer Axles – 1/Unl/P&L
MX-08-130-FV (FSD-08A)
MX-10-130-FV (FSD-10A)
MX-12-130-FV (FSD-12A)
MX-13-130-FV (FSD-13A)
MX-14-130-FV (FSD-14A)
MX-16-130-FV (FSD-16A)
MX-18-130-FV (FSD-18A)
MX-18-130-SD (SDA-1800)
MX-20-130-FV (FSD-20A)
MX-21-130-FV (FSD-21A)
MX-21-130-SD (SDA-2100)
MX-23-130-FV (FSD-23A)
MX-23-130-SD (SDA-2300)

HEAVY SERVICE/SPECIALTY VEHICLE

WARRANTY INFORMATION
MX-10-120
MX-10-120 EVO
MX-12-120
MX-12-120 EVO
MX-14-120
MX-14-120 EVO
MX-16-120
MX-18-120
MX-17-140
MX-19-140
MX-21-140
MX-21-160
MX-23-160
MX-23-810
Front Drive Steer Axles – 2/Unl/P&L
MPT-170
MPT-180
MPT-185
MPT-309
MPT-500
MPT-518
MPT-1702
PTO – 1/Unl/P&L

11.113
11 Drivelines
RPL 3/Unl/P, 1/Unl/P&L
92N 1/Unl/P&L
MXL 1/Unl/P&L
Transmission – 1/Unl/P&L
FAT 30
Brake Components
Cam P 3/Unl/P
Cam P 2/100/P
Cam Cast Plus™ 2/100/P&L
Q+ Drum Brake™1 3/Unl/P&L
Q+ Drum Brake™2 2/100/P&L
ASA 3/Unl/P
ASA2 2/100/P
Hubs/Cast Drums and Other Wheel-End Components3 1/Unl/P Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake4 2/100/P&L
1 For Trailer only, 3/300/P against rust jacking when equipped with Platinum Shield III. 2
Applies to City Bus, Trolley, Shuttle Bus and Airport Shuttle only. 3 Based on stamped wear diameter max. 4
Warranty coverage for boots, seals, caps, bushings and pins is 2/100/P.

Warranty coverage for pads is 1/100/P.

Trailer Axles1
Beam and Brackets2 5/Unl/P, 1/Unl/L
Wheel End Systems3
Standard System4 1/Unl/P&L
1 For brake components coverage, refer to appropriate product warranties. 2 9000 Series is 3/Unl/P, 1/Unl/L 3 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage. 4 When installed by Cummins-Meritor.

Trailer Air Suspension Systems1
MTA and MTA-Tec6 Trailing Arm Suspension System
Major Structural Components2 5/500/P, 1/100/L
Height Control Valve 1/100/P&L
Air Springs 2/200/P, 1/100/L
Bushings2 5/500/P, 3/300/L
Shock Absorbers 2/200/P&L
Lift Kit System 1/100/P&L
1 For axle coverage, refer to appropriate product warranties. 2 Raw wood applications 3/Unl/P, 1/Unl/L
Meritor Tire Inflation System
(MTIS)
MTIS Components 5/Unl/P, 1/Unl/L
Gearboxes – 1/Unl/P&L
MGX-402
MGX-423
MGX-450
MGX-451
MGX-466
MGX-479
MGX-538
Transfer Cases – 1/Unl/P
MTC-2212-CV (306)
MTC-3106-FV (TC-137)
MTC-3111 (T-2111)
MTC-3112-CV (548C)
MTC-3116 (T-2111 through-shaft)
MTC-3118-FV (TC-180 and TC-180-23)
MTC-3118-CV (358)
MTC-3120-FV (TC-143)
MTC-3124 (T-2119)
MTC-3203
MTC-3205-GV (MTC-25/RTC-25)
MTC-3206-FV (TC-237)
MTC-3206-CS (544)
MTC-3208-GV (RTC-50)
MTC-3209-GV (MTC-60/RTC-60)
MTC-3212-CV (315 and 548B)
MTC-3312-FV (TC-270)
MTC-3220-FC (TC-142)
MTC-4206-FV (TC-38)
MTC-4208
MTC-4210
MTC-4213

HEAVY SERVICE/SPECIALTY VEHICLE

WARRANTY INFORMATION

11.114
12 Fire and Emergency Vehicles
Aerial Ladder Truck
Aerial Platform
Ambulance
Command Vehicle
Crash Fire Rescue
Pumper
Rapid Intervention
Vehicle (RIV)
Tanker
Fire and Emergency Typically Is:

Lower mileage operations (less than 20,000 miles/year)
Generally, on-road service (less than 10% off-road)
An average of three (3) miles between starting and stopping Front Non-Drive Steer Axles – 5/Unl/P&L
FL-941
FL-943
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
Rear Drive Single Axles – 5/Unl/P&L
RC-23-160
RS-23-160
RS-23-161
RS-23-185
RS-23-186
RS-24-160
RC-25-160
RS-26-185
RS-30-185
RS-35-1851
RS-25-160
1 2/Unl/P&L if PreSet by Cummins-Meritor.

Rear Drive Tandem/Tridem Axles – 5/Unl/P&L
MT-40-14X/P
RT-40-160/P
MT-44-14X/P
RT-46-160/P
RT-46-164/P
RT-46-169
RT-50-160/P
MT-52-616
RT-52-1851
MT-58-616
RT-58-1851
MT-70-3802
1 Each vehicle must have a Request for Application Recommendation (RAR) approved by Cummins-Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details. 2 2/Unl/P&L Front Drive Steer Axles – 2/Unl/P&L
MX-19-140 MX-21-140 MX-21-160 MX-23-160 MX-23-810

FIRE AND EMERGENCY

WARRANTY INFORMATION
Coverage under Cummins-Meritor’s warranty require
that the application of products be properly approved
pursuant to OEM and Cummins-Meritor approvals.

Refer to TP-9441 for axles, TP-12126 for drivelines
and/or contact Cummins-Meritor regarding specific
application approval questions on any product line.

Transfer Cases – 1/Unl/P
MTC-2212-CV (306)
MTC-3106-FV (TC-137)
MTC-3111 (T-2111 through-shaft)
MTC-3112-CV (548C)
MTC-3118-FV (TC-180 and TC-180-23)
MTC-3118-CV (358)
MTC-3120-FV (TC-143)
MTC-3124 (T-2119)
MTC-3206-FV (TC-237)
MTC-3206-CS (544)
MTC-3208-GV (RTC-50)
MTC-3209-GV (MTC-60/RTC-60)
MTC-3212-CV (315 and 548B)
MTC-3312-FV (TC-270)
MTC-3220-FC (TC-142)
MTC-4206-FV (TC-38)
MTC-4208
MTC-4210
MTC-4213

11.115
13 PTO – 1/Unl/P&L
MPT-170
MPT-180
MPT-185
MPT-309
MPT-500
MPT-518
MPT-1702

FIRE AND EMERGENCY

WARRANTY INFORMATION
Brake Components
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
ASA 3/Unl/P
Hubs/Cast Drums and Other Wheel-End Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake™1 2/Unl/P&L
1 Warranty coverage for boots, seals, caps, bushings and pins is 2/200/P.

Warranty coverage for pads is 1/100/P.

Drivelines
RPL 4/400/P, 1/Unl/L
MXL 3/350/P, 1/Unl/L
92N 1/Unl/P

11.116
14 Transit Bus Vehicles
Airport Shuttle
City Bus
Commuter Coach
Shuttle Bus
Transit Bus Trolley
Transit Bus Typically Is:

Moderate mileage operation (less than 50,000 miles per year) Moderate to frequent stops/starts (up to 10 stops per mile) Front Non-Drive Steer Axles – 5/300/P&L
FH-946 FH-9411 MFS-12-155 MFS-13-155
1 Commuter coach only – 2/Unl/P&L
Tag Axles – 2/Unl/P&L
Brake Components
Cam Cast Plus™ 2/100/P&L
Q+ Drum Brake™1 2/100/P&L
ASA1 2/100/P
Hubs/Cast Drums and Other Wheel-End Components 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake2 2/100/P&L
1 Applies to City Bus, Trolley, Shuttle Bus and Airport Shuttle only. 2 Warranty coverage for boots, seals, caps, bushings and pins is 2/100/P.

Warranty coverage for pads is 1/100/P.

Drivelines
RPL 3/Unl/P, 1/Unl/L
92N 1/Unl/P&L
MXL 1/Unl/P&L
1 Commuter coach only – 2/Unl/P&L
Rear Drive Single Axles – 5/300/P&L
RS-23-160
RC-23-161
71163
79163
RC-23-1621
RC-23-1651
RS-21-160
MC-14002 MC-16003 FH-946
Center Non-drive Axles – 5/300/P&L
MC-26000 71063 79063
Gearboxes – 1/Unl/P&L
MGX-450 MGX-451 MGX-538

TRANSIT BUS

WARRANTY INFORMATION
Coverage under Cummins-Meritor’s warranty require
that the application of products be properly approved
pursuant to OEM and Cummins-Meritor approvals.

Refer to TP-9441 for axles, TP-12126 for drivelines
and/or contact Cummins-Meritor regarding specific
application approval questions on any product line.

11.117
15 Industrial and Off-Highway Service Vehicles
Load-On/Load-Off
Port Tractor
Rail Yard Spotter
Roll-On/Roll-Off
Stevedoring Tractor
Trailer Spotter
Yard Jockey
All and Rough
Terrain Cranes
Forestry
Material Handling
Specialized Heavy
Haul
Excavator
Compactor
Fertilizer Spreader
Snow Blower
Mining and
Specialized Mining
Rail Car Mover
Loader
Tow Tractor
Pushback Tractor
Industrial and Off-Highway Service Typically Is:

Low mileage operation
Low speed vehicle speed restriction
Vehicles are not typically licensed for highway use
Six (6) starts/stops per mile (typical)
Front Non-Drive Steer Axles – 1/Unl/P
FF - 941
FF - 943
FF - 961
FF - 966
FG - 941
FG - 943
FL - 941
FL - 943
FN - 951
FS-25
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
MON-Z0 FAMILY
Gearboxes – 1/Unl/P&L
MGX-402
MGX-423
MGX-450
MGX-451
MGX-466
MGX-479
MGX-538
PTO – 1/Unl/P&L
MPT-170
MPT-180
MPT-185
MPT-309
MPT-500
MPT-518
MPT-1702
1 2/Unl/P for LO/LO Terminal Tractor applications
Planetary Axles – 1/Unl/P
MOB
MOC
MOD
MOE
MOF
MOG
MOH
MOR
MOS
MOT
MOX
MOY
MOZ
Rear Drive Axles – 1/Unl/P
MT-14X1
RS-23-186
RS-23-380
RS-24-160
RS-30-185
RS-30-380
RT-1451
RT-1601

OFF-HIGHWAY SERVICE

WARRANTY INFORMATION
Coverage under Cummins-Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Cummins-Meritor approvals. Contact Cummins-Meritor regarding specific application approval questions on any product line.

11.118
16 Drivelines – 1/Unl/P

RPL MXL
Transmission – 1/Unl/P&L
FAT 30
Brake Components
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
ASA 3/Unl/P
Hubs/Cast Drums and Other Wheel-End Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P

OFF-HIGHWAY SERVICE

WARRANTY INFORMATION
Transfer Cases – 1/Unl/P
MTC-2212-CV (306)
MTC-3106-FV (TC-137)
MTC-3111 (T-2111 through-shaft)
MTC-3112-CV (548C)
MTC-3116 (T-2111)
MTC-3118-FV (TC-180 and TC-180-23)
MTC-3118-CV (358)
MTC-3120-FV (TC-143)
MTC-3124 (T-2119)
MTC-3206-FV (TC-237)
MTC-3208-GV (RTC-50)
MTC-3209-GV (MTC-60/RTC-60)
MTC-3220-FC (TC-142)

11.119
17 Coverage Exclusions
Product Description
All
The cost of any repairs, replacements or adjustments to a covered component (1) associated with noise; (2) resulting from the use or installation of non-genuine Cummins-Meritor components or materials; (3) due to vibration associated with improper operation or misapplication of drivetrain components; and (4) damage resulting from corrosion.

For axle assemblies supplied by Cummins-Meritor with suspension and interface brackets designed and/or attached by nonCummins-Meritor parties, Cummins-Meritor warranty coverage does not apply to the brackets, bracket attachment methods and field issues caused by brackets or bracket attachments to any covered component unless specified in a separate OEM agreement.

Front Axles1
Linehaul – King Pin Bushings 1yr/Unl P&L
All Other Vocations – King Pin Bushings Excluded
1 King Pin Bushing wear excluded for all vocations.

Rear Axles
Self-contained traction equalizers and oil filters. The use of NoSPIN differentials will result in the exclusion of axle shafts from warranty considerations. NoSPIN is a product of Eaton.

ASA
Boot and bushing. Bent, broken, over-torqued, missing or otherwise damaged pawl assemblies.

Cam Brake
Brake lining wear and brake shoe “rust-jacking.”
Disc Brake
Pad wear, rotor wear.

Coverage Limitations
Product Description
All
Any claim beyond 60 days from date of repair will not be accepted or honored under this warranty program. Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles parts only (1/Unl/P).

Warranty coverage on vehicles with 1,850 lb-ft engine torque and over may be reduced on individual drivetrain components. Contact your Cummins-Meritor representative for specific details.

Front Axles
Tie rod and tie rod ends limited to 3-year/300,000-mile or published vocational coverage, whichever is less. Wheel seals, gaskets and wheel bearings are covered for 1 year/unlimited miles if the wheel end equipment is supplied and assembled by Cummins-Meritor.

Rear Axles
Pinion and through shaft seals limited to 3-year/300,000-mile or published vocational coverage, whichever is less, if yoke is installed by Cummins-Meritor. If yoke is not installed by CumminsMeritor, then Cummins-Meritor does not warrant pinion seals.

Wheel seals, gaskets and wheel bearings are covered for 1 year/unlimited miles if the wheel end equipment is supplied and assembled by Cummins-Meritor.

Rear Axles
The Cummins-Meritor breather part number A-2297-C-8765 with A-3196-J-1336 hose must be used for eligibility of any potential warranty consideration relating to contamination and/or loss of lube in axles.

Cam Brake
Limited to bracket, brake spider and camshaft structural integrity.

STEELite X30
Wearable life is up to the discard diameter of the drum.

Terms and Conditions
(1) What is Covered by this Commercial Warranty?
Meritor Heavy Vehicle Systems, LLC warrants to the owner (“Owner”) that the components listed in this publication, which have been installed by an Original Equipment Manufacturer (“OEM”) as original equipment in vehicles licensed for on-highway use, will be free from defects in material and workmanship. This warranty coverage begins only after the expiration of the OEM’s vehicle warranty for the applicable covered components. Warranty coverage ends at the expiration of the applicable time period from the date of vehicle purchase by the first Owner or the applicable mileage limitation, whichever occurs first. Duration of coverage varies by component and vocation as detailed elsewhere in this warranty statement.

Some components are warranted for parts only and the Owner must pay any labor costs associated with the repair or replacement of the component.

Other components are warranted for both parts and reasonable labor to repair or replace the subject component. Components (whether new, used or remanufactured) installed as replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty.

For certain components, coverage requires the use of specific extended drain interval or synthetic lubricants. For further information about lubrication and maintenance, see Cummins-Meritor publication Maintenance Manual Number l and the applicable Cummins-Meritor maintenance manual for the product in question. Other conditions and limitations applicable to this warranty are detailed below.

TERMS AND CONDITIONS

11.120
Product models, brands, names and trademarks depicted herein are the property of their respective owners and, except where otherwise indicated, are not in any way associated with Meritor Heavy Vehicle Systems, LLC, or any parent or affiliate, thereof. (2) Designation of Vocational Use Required
To obtain warranty coverage, each Owner must notify Cummins-Meritor through the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the Cummins-Meritor components have been incorporated prior to the vehicle in-service date. This notification may be accomplished by registering the vehicle through your OEM new truck and/or trailer dealer or with Cummins-Meritor directly. Failure to notify CumminsMeritor of (I) the intended vocational use of the vehicle or (II) a change in vocational use from that which was originally designated, will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial in-service date.

A second Owner and each subsequent Owner must also notify CumminsMeritor as to the intended vocational use of the vehicle. This notification can be sent directly to Cummins-Meritor or through the OEM new truck and/ or trailer dealer. The duration and mileage coverage of this warranty cannot exceed the coverage extended to the first Owner after his or her initial designation of vocational use.

Coverage under Cummins-Meritor’s warranty requires that the application of products be properly approved pursuant to OEM and Cummins-Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines and/or contact Cummins-Meritor regarding specific application approval questions on any product line.
(3) What is the Cost of this Warranty?
There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty?
This warranty does not cover normal wear and tear; nor does it cover a component that fails, malfunctions or is damaged as a result of (I) improper installation, adjustment, repair or modification (including the use of unauthorized attachments or changes or modification in the vehicle’s configuration, usage or vocation from that which was originally approved by Cummins-Meritor), (II) accident, natural disaster, abuse or improper use (including loading beyond the specified maximum vehicle weight or altering engine power settings to exceed the axle and/or driveline capacity) or (III) improper or insufficient maintenance (including deviation from approved lubricants, change intervals or lube levels). This warranty does not cover any component or part that is not branded by Cummins-Meritor. For vehicles that operate full or part time outside of the United States and Canada, a one year, unlimited mileage, parts only warranty (1/Unl/P) will apply.
(5) Remedy
The exclusive remedy under this warranty shall be the repair or replacement of the defective component at Cummins-Meritor’s option. Cummins-Meritor reserves the right to require that all applicable failed materials are available and/or returned to Cummins-Meritor for review and evaluation. (6) Disclaimer of Warranty

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES

OR CONDITIONS, EXPRESSED, IMPLIED OR STATUTORY INCLUDING

ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
PARTICULAR PURPOSE.
(7) Limitation of Remedies
In no event shall Cummins-Meritor be liable for special, incidental, indirect or consequential damages of any kind or under any legal theory, including, but not limited to, towing, downtime, lost productivity, cargo damage, taxes or any other losses or costs resulting from a defective covered component. (8) To Obtain Service
If the Owner discovers within the applicable coverage period a defect in material or workmanship, the Owner must promptly give notice to either Cummins-Meritor or the dealer from which the vehicle was purchased. To obtain service, the vehicle must be taken to any participating OEM new truck and/or trailer dealer or authorized Cummins-Meritor service location. The dealer will inspect the vehicle and contact Cummins-Meritor for an evaluation of the claim. When authorized by Cummins-Meritor, the dealer will repair or replace during the term of this warranty any defective Cummins-Meritor component covered by this warranty.
(9) Entire Agreement
This is the entire agreement between Cummins-Meritor and the Owner about warranty and no Cummins-Meritor employee or dealer is authorized to make any additional warranty on behalf of Cummins-Meritor. This agreement allocates the responsibilities for component failure between Cummins-Meritor and the Owner.

TERMS AND CONDITIONS
Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.
cummins.com
SP-95155
Bulletin 6451105 Produced in U.S.A. Rev. 1/24
©2024 Meritor, Inc.

11.121
)LUHDQG5HVFXH$SSDUDWXV
Coverage:
7KUHH

<HDU0DWHULDODQG:RUNPDQVKLS
0HULWRU:DEFR$%6%UDNH6\VWHP
Limited Warranty Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The Meritor Wabco ABS brake system shall be covered by
Meritor Wabco as indicated in the attached Meritor Wabco warranty coverage description
/,0,7(':$55$17<
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Three (3) Year Warranty Period
Ends After:

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

The exclusions listed in the attached Meritor Wabco warranty description shall apply.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
(;&/86,212)&216(48(17,$/$1',1&,'(17$/'$0$*(6
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
%8<(5
6(;&/86,9(5(0('<
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/25/2013 WA0232
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
',6&/$,0(562):$55$17,(6
capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

11.122

WARRANTY
Warranty coverage is essential to protecting your investment. But understanding the full details of your coverage can be challenging. This straightforward approach allows you, our valued customer, to better understand how your specific vehicle applications will be covered in your region. Our component warranty coverage is provided according to vocation/usage categories listed below. • Linehaul covers high mileage operation (over 60,000 miles/year) on well-maintained major highways of concrete or asphalt construction.
• General Service covers moderate mileage operations (less than 60,000 miles/year) on well-maintained public roads (less than 10 percent off-road) typically with less than three (3) stops per mile. • Heavy Service (Vocational) covers vehicles with more than 10 percent off-road OR moderate to frequent starts/stops typically with more than three (3) stops per mile.
• Off-Highway Service covers lower mileage operations. Vehicles are not typically licensed for highway use. • The standard aftermarket warranty for WABCO products - including WABCO Original parts, WABCO Reman Solutions, ProVia quality aftermarket parts and WABCO retrofit solutions - is one year, parts only from in-service date when purchased from ZF distributor networks or its affiliates and/or subsidiaries.

MODEL YEAR 2021 VEHICLES
How to Read Warranty Coverage (Example)
Number of Years Mileage (in thousands) Unl=Unlimited P=Parts Only P&L=Parts & Labor 3 300 P

11.123
WARRANTY - MODEL YEAR 2021 VEHICLES
¹ ZF and WABCO branded components. 2
WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve.
• Aerial Ladder Truck
• Aerial Platform
• Ambulance
• Auto Hauler
• Beverage Truck
• Bulk Hauler
• Chip Hauler (Truck)
• Cross Country Coach
• Doubles
• Flatbed
• Front Engine Commercial
Chassis
• Front Engine Integral
Coach
• General Freight
• Grain Hauler
• Intercity Coach
• Intermodal Chassis
• Livestock Hauler
• Meat Packer
• Moving Van
• Municipal Truck
• Pipe Hauler
• Platform Auto Hauler
• Pumper
• Rear Engine Integral Coach
• Recreational Vehicles
• Refrigerated Freight
• School Bus
• Stake Truck
• Tanker
• Tanker Truck
• Triples
• Tour Bus
• Wrecker

LINEHAUL/GENERAL SERVICE VEHICLES

LINEHAUL/GENERAL SERVICE WARRANTY INFORMATION

LINEHAUL TYPICALLY IS
• High mileage operation (over 60,000 miles/year)
• Well maintained major highways of concrete or
asphalt construction

GENERAL SERVICE TYPICALLY IS
• Moderate mileage operations (less than 60,000 miles/year) • Well maintained public roads (less than 10% off-road) • Less than three (3) stops per mile
WABCO Components1
Air Management
Air Brake Valves
Trailer Lift Axle Control Valve 1/100/P&L
Trailer Control Line Filter3
Air Compressors (ALL)2 2/200/P&L
Air Dryers (ALL) 3/300/P&L
Aerodynamics
OptiFlow® TrailerSkirt 2/UnU/P
OptiFlow® Trailer Tail and AutoTail 2/UnI/P
Braking Systems
ABS (Anti-Lock Braking System) Air
3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic
Electronic Braking System (EBS)
Electronic Stability Control (ESC)
Roll Stability Control (RSS)
Trailer Roll Stability Support (RSS)
Trailer ABS (Anti-Lock Braking System)3
Driveline Suspension Control
Clutch Controls 2/200/P&L
Leveling Valves
1/100/P&L
OptiRide® Automated Manual Transmission (AMT)
OptiRide® Electronically Controlled Air Suspension
(ECAS) 3/300/P&L
WABCO Components1 (cont.)
Safety
OnGuardACTIVE®
3/300/P&L
OnLane®
OnLaneALERT®
OnSide®
Trailer SafeStart™
Trailer TailGUARD™
Telematics
TrailerCAST™ Telematics Device 3/300/P&L
Wheel End Solutions
EasyFit™ Slack Adjuster 6/600/P
MAXXUS™ Truck Air Disc Brake 5/500/P&L
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 17 and 19 Air Disc Brake 2/Unl/P and
1/Unl/L
Pan 22 Air Disc Brake 5/500/P and 1/L
TRISTOP™ D Actuator w/ IBV or IRB 6/600/P
TRISTOP™ D Actuator 3/300/P
UNISTOP™ Actuator 2/200/P
Trailer MAXX22T™ Air Disc Brake 5/500/P and 1/L

11.124
1 ZF and WABCO branded components. 2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve.

WABCO Components1
Air Management
Air Brake Valves
1/100/P&L Air Compressors (ALL)2
Air Dryers (ALL)
Trailer Control Line Filter3
Braking Systems
ABS (Anti-Lock Braking System) Air 3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic 2/200/P&L
Electronic Braking System (EBS)
3/300/P&L
Electronic Stability Control (ESC)
Trailer ABS Valve3
Roll Stability Control (RSS)
Trailer Roll Stability Support (RSS)
Driveline Suspension Control
OptiRide® Electronically Controlled Air Suspension
(ECAS) 2/200/P&L
Leveling Valves 1/100/P&L
Clutch Controls 2/200/P&L
Safety
OnGuardACTIVE®
3/300/P&L
OnLane®
OnLaneALERT®
OnSide®
Trailer SafeStart™
Trailer TailGUARD™
Telematics
TrailerCAST™ Telematics Device 3/300/P&L
Wheel End Solutions
EasyFit™ Slack Adjuster 2/200/P
MAXXUS™ Air Disc Brake 1/Unl/P&L
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 22, 19 and 17 Air Disc Brake 1/Unl/P&L
Trailer MAXX22T™ 1/Unl/P&L
TRISTOP™ D Actuator w/ IBV 3/Unl/P
TRISTOP™ D Actuator 2/200/P
UNISTOP™ Actuator 1/100/P
• Airport Rescue Fire (ARF)
• Airport Shuttle
• Asphalt Truck
• Block Truck
• Bottom Dump Trailer
Combination
• Cementing Vehicle
• City Bus
• Commercial Pick-Up
• Concrete Pumper
• Construction Material Hauler
• Crash Fire Rescue (CFR)
• Mixer
• Demolition
• Drill Rig
• Dump
• Emergency Service
• Equipment Hauling
• Flatbed Trailer Hauler
• Flatbed Truck
• Fracturing Truck
• Front Loader
• Geophysical Exploration
• Hopper Trailer Combinations
• Landscaping Truck
• Liquid Waste Hauler
• Log Hauling
• Lowboy
• Michigan Special
Gravel Trains
• Michigan Special
Log Hauler
• Michigan Special
Steel Hauler
• Michigan Special
Waste Vehicle
• Municipal Dump
• Newspaper Delivery
• Package Delivery
• Pick-up and Delivery
• Rapid Intervention
Vehicle (RIV)
• Rear Loader
• Recycling Truck
• Residential Pick-Up/Waste
• Rigging Truck
• Roll-Off
• Scrap Truck
• Semi-End Dump
• Sewer/Septic Vacuum
• Shuttle Bus
• Side Loader
• Snowplow/Snowblower
• Steel Hauling
• Tanker
• Tank Truck
• Tractors with Pole Trailers
• Tractor/Trailer with Jeeps
• Transfer Dump
• Transfer Vehicle
• Transit Bus
• Trolley
• Utility Truck
• Winch Truck

HEAVY SERVICE VEHICLES

HEAVY SERVICE (VOCATIONAL) WARRANTY INFORMATION

HEAVY SERVICE TYPICALLY IS
• On/Off road vocations (10% or more off-road) OR
• Moderate to frequent starts/stops typically more than three (3) stops per mile

11.125
WARRANTY - MODEL YEAR 2021 VEHICLES

INDUSTRIAL AND OFF-HIGHWAY SERVICE

TYPICALLY IS
• Low mileage operation3
• Vehicles are not typically licensed for highway use
¹ ZF and WABCO branded components. 2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 Equivalent hours of service limit: 2,000 hours for all components.

INDUSTRIAL/OFF-HIGHWAY SERVICE WARRANTY INFORMATION
WABCO Components1
Air Management
Air Brake Valves
Air Compressors (ALL)2 2/Unl/P
Air Dryers (ALL)
Brake Actuation
Air/Hydraulic Actuators
2/Unl/P
Master Cylinders
Remote Actuators
Slave and Wheel Cylinders
Two Fluid Actuators
Brake Locks
Brake Locks (ALL)
Electric Brake Locks 2/Unl/P
Lever Locks
Braking Systems
ABS (Anti-Lock Braking System) Air 1/100/P&L
ABS (Anti-Lock Braking System) Hydraulic
Driveline Suspension Control
Clutch Controls
1/100/P&L
Leveling Valves
Electrohydraulics & Controls
Electronic Pedals
Electrohydraulic Brake Valves (EBV) 2/Unl/P
Pressure Switches
Hydraulic Braking Solutions
Accumulator Charging Valves
Hydraulic Throttle Controls and Switches 2/Unl/P
Modulating Brake Valves
Wheel End Solutions
EasyFit™ Slack Adjuster 2/200/P
Caliper Disc Brakes 2/Unl/P
MAXXUS™ Air Disc Brake 1/Unl/P&L
Multiple Disc Brakes 2/Unl/P
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 22, 19 and 17 Air Disc Brake 1/Unl/P&L
TRISTOP™ D Actuator w/ IBV 3/Unl/P
TRISTOP™ D Actuator 2/200/P
UNISTOP™ Actuator 1/100/P
Market Common Application Types
Agriculture
Fertilizer Spreader, Tractor, Heavy Duty Ag
Trailers, Harvester, Sprayer, Skid Loader, Silage
Bagger, Slurry Wagons, Grain Cart
Airport Support
Pushback Tractor, Towing Tugs, Aircraft Tow
Tractor, Refueling Trucks, Food Service Trucks,
Baggage Tractors, De-Icing Equipment,
Runway Clearing Equipment
Construction
All-Terrain Crane, Rough Terrain Crane,
Excavator, Compactor, Wheel Loader, Road
Roller, Motor Grader, Articulated Dump Truck,
Rubber Tire Road Roller, Backhoe Loaders,
Haul Trucks, Scraper Rough Terrain Forklifts,
Trenchers, Drills
Forestry Logging Forwarder, Kidder, Loaders, Yard
Forklifts, Harvesters Fellers
Material Handling
Port Tractor, Rail Yard Spotter, Stevedoring
Tractor, Trailer Spotter, Yard Jockey, Scissor
Lift, Straddle Carrier, Manlift, Forklift, Boom Lift
Telebandlers, Aerial Work Platforms
Mining
Specialized Mining, Excavator, Haul Truck,
Underground Loader, Service Trucks, Wheel
Loaders, Scrapers, Load Haul Dumps,
Personnel Transports, Bolters, Scalers
Municipal
Street Sweeper, Utility Tractor, Utility Trucks,
Tree Trimmers, Dump Trucks, Tow Trucks, Flat
Bed Trucks, Winch Applications
Oil & Gas
Fracturing Trailer, Injecter Heads, Top Drives,
Jack/Lift Boats, Wireline Trucks, Load-On /
Load-Off
Rail
Railcar Mover, Track Layers, Grinders, Platform
Crane, Locomotive Railcars, Ballast Equipment,
Winch Applications

11.126

ABS, ELECTRONIC STABILITY CONTROL (ESC),
ROLL STABILITY CONTROL (RSC), OPTIRIDE®,
ONGUARD® AND ONLANE®, COLLECTIVELY
“ELECTRONICS”
Failure of electronic components due to overvoltage
condition, improper grounding, electrostatic discharge
(ESD), improper shielding, electromagnetic interference (EMI), or other wiring or installation issues. Malfunctions and failure codes caused by other electronic subsystem failures (data bus, engine, transmission, dashboard, etc.)

HYDRAULIC COMPONENTS
For certain components, brake fluid DOT3 or DOT4 is
used as the operating medium. Use of any other fluid will void all warranties associated with that component. For hydraulic braking applications the brake fluid is considered a maintenance item. Maintenance intervals are listed in TB1367.

COVERAGE LIMITATIONS

PRODUCT DESCRIPTION

ALL PRODUCTS
Any claim beyond 60 days from date of repair will not be accepted or honored under this warranty program.

Products purchased on an incomplete vehicle (glider) are limited to one year, 1/Unl/P.

For vehicles that operate full- or part-time outside of the United States and Canada, a 1-Year/Unlimited Miles parts only (1/Unl/P) will apply.

TOOLBOX PLUS™ DIAGNOSTIC SOFTWARE
Proper diagnostics of WABCO Electronics may require the latest version of TOOLBOX PLUS™. Additional labor due
to use of an outdated version of TOOLBOX™ software
and/or the time to purchase or install the latest version of TOOLBOX PLUS™ are not covered under product
warranty.

TERMS AND CONDITIONS

COVERAGE EXCLUSIONS

PRODUCT DESCRIPTION

ALL PRODUCTS
This Warranty shall not apply to the following, but not limited to: (1) damage to the product or its component
parts caused by incorrect use, installation, maintenance or repair, including without limitation (a) improper fit of mating components or brackets, damaged threads, cut, broken,
chafed, pinched or otherwise damaged wiring (sensors,
harnesses and connectors), (b) sensors damaged during
removal when seized in block, or associated with sensor adjustments/ alignments, and (c) damage resulting from the use or installation of non-genuine WABCO components or
materials; (2) damage to the product, its component parts, or diminished product or component part performance due to incorrect operation, deviation from approved conditions or misapplication; (3) any unauthorized disassembly of the product or its component parts including without limitation (a) obliterated, defaced or missing WABCO or WABCO
name plate, serial numbers or label identifying the device as a ZF product or WABCO component, (b) changes to sealed
adjusting screws, and (c) opening or attempted repair of non-serviceable components; (4) malfunction
of the component due to internal contamination of the
vehicle system including without limitation (a) water and other contamination damage that is due to the use of a
non-genuine air dryer cartridge or (b) valve failures due to contamination in air system, (5) complaints associated
with noise, (6) damage resulting from corrosion (including oxidation of electrical devices and connections).

AIR DRYERS
Mounting brackets (see vehicle OEM). Desiccant cartridge housing only.

AIR SYSTEM COMPONENTS
Normal wear items; Gladhand seals, dash valve knobs,
valve actuation handles, treadles, pedals.

11.127
WARRANTY - MODEL YEAR 2021 VEHICLES
(1) What is Covered by this Commercial Warranty?
ZF CV Systems North America LLC and its North American
subsidiaries and affiliates (ZF) warrant to the owner (“Owner”) that the components listed in this publication, which have been installed by an Original Equipment Manufacturer (“OEM”) as original equipment will be free from defects in material and workmanship. This warranty coverage begins from the original in-service date to the limits provided and runs concurrently with any warranties provided by OEMs and/or any distribution agreements and/or any service contracts that cover the components listed in this publication, if any. If the components listed in this publication are covered by an OEM warranty and/or service contract, then the OEM’s warranty and/ or service contract shall supersede ZF’s warranty and Owner shall comply with all OEM’s warranty and/or service contract requirements for claims under such OEM’s warranty and/or service contract until those agreements expire.

Once those agreements expire and provided the ZF warranty has not expired under the terms stated above, the ZF warranty will be in effect until its expiration date.

Warranty coverage ends at the expiration of the applicable time period from the date of vehicle purchase by the first Owner, or, the applicable mileage limitation, whichever occurs first. Duration of coverage varies by component and vocation as detailed previously in this publication.

Some components are warranted for parts only and the Owner must pay any labor costs associated with the repair or replacement of the component. Other components are warranted for both parts and reasonable labor to repair or replace the subject component.

Additional diagnostic time due to use of an outdated version of TOOLBOX™, time to purchase or install latest version of TOOLBOX™ are the responsibility of the authorized ZF distributor networks and are not covered under product warranty. Components installed as replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty. (2) Designation of Vocational Use Required. To obtain warranty coverage, each Owner must notify ZF through the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the WABCO components have been incorporated prior to the vehicle inservice date. This notification may be accomplished by registering the vehicle through your OEM new truck and/or trailer dealer or with ZF directly. Failure to notify ZF of (I) the intended vocational use of the vehicle or (II) a change in vocational use from that which was originally designated, will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial inservice date. A second Owner and each subsequent Owner must also notify ZF as to the intended vocational use of the vehicle. This notification can be sent directly to ZF or through
the OEM new truck and/or trailer dealer. The duration and mileage coverage of this warranty cannot exceed the coverage extended to the first Owner after his or her initial designation of vocational use. Coverage under ZF’s warranty requires that the application of products be properly approved pursuant to OEM and ZF, approvals. (3) What is the Cost of this Warranty? There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty? In addition to the items listed on "Coverage Exclusions," this warranty does not cover normal wear and tear, or service items; nor does it cover a component that fails, malfunctions or is damaged as a result of (a) improper handling, storage, installation, adjustment, repair or modification including the use of unauthorized attachments or changes or modification in the vehicle’s configuration, usage, or vocation from that which was originally approved by ZF, (b) accident, fire or other casualty, natural disaster, road debris, negligence, misuse, abuse, or improper use (including loading beyond the specified maximum vehicle weight or altering engine power settings to exceed the brake system capacity), or (c) improper or insufficient maintenance (including deviation from maintenance intervals, approved lubricants, or lube levels). This warranty does not cover any component or part that is not sold by ZF. (5) To obtain service. If the owner discovers within the applicable coverage period a defect in material or workmanship, the Owner must promptly give notice to either ZF or the dealer from which the vehicle was purchased. To obtain service, the vehicle must be taken to any participating OEM dealer or ZF distributor networks' servicer. The dealer or ZF authorized servicer will inspect the vehicle and contact ZF for an evaluation of the claim. When authorized by ZF, the dealer or ZF authorized servicer will repair or replace during the term of this warranty any defective WABCO component covered by this warranty. (6) Disclaimer of Warranty and Limitation of remedies. TO THE MAXIMUM

EXTENT PERMITTED BY LAW, THE LIMITED WARRANTY SET

FORTH HEREIN IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED, ARISING BY OPERATION OF

LAW OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY

IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE AND/OR WARRANTY FOR HIDDEN OR

LATENT DEFECTS, AND IN NO EVENT WILL ZF OR ANY OF ITS

AFFILIATES BE LIABLE FOR DIRECT, INDIRECT, INCIDENTAL,

PROGRESSIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES OF ANY
KIND.

TERMS AND CONDITIONS

11.128
(7) Legal action. Any legal action or claim arising from or related to this Warranty, in contract or otherwise, must be commenced within one year from the accrual of that cause of action, or be barred forever. Any dispute arising in connection with this agreement shall be governed by and construed according to the laws of the State of Michigan and be brought, heard and determined exclusively in either the Circuit Court for the County of Oakland, State of Michigan or the United States District Court for the Eastern District of Michigan. The parties stipulate that the referenced venues are convenient.
(8) Remedy. The exclusive remedy under this warranty shall be the repair or replacement of the defective component at ZF's option. ZF reserves the right to require that all applicable covered components are available and/or returned to ZF for review
and evaluation. THE MAXIMUM LIABILITY, IF ANY, OF ZF FOR ALL

DAMAGES, INCLUDING WITHOUT LIMITATION CONTRACT

DAMAGES, BREACH OF WARRANTY, NEGLIGENCE, STRICT

LIABILITY, OR OTHER TORT, IS LIMITED TO AN AMOUNT NOT TO EXCEED THE PURCHASE PRICE OF THE PRODUCT and where
indicated in the product and application warranty information above, the inclusion of labor is limited to the standard repair time. THE

PARTIES ACKNOWLEDGE AND AGREE THAT THE LIMITATION

OF DAMAGES PROVISION SET FORTH IN THIS PARAGRAPH

SURVIVES BETWEEN THE ORIGINAL END USER AND ZF EVEN IF

THE EXCLUSIVE REMEDY SET FORTH ABOVE IS DEEMED TO FAIL
OF ITS ESSENTIAL PURPOSE. ZF may change the design or make improvements to its Products without incurring any warranty obligation for previously manufactured Product .
(9) Entire Agreement. This is the entire agreement between ZF and the Owner about warranty and no, ZF employee, or dealer is authorized to make any additional warranty on behalf of ZF unless in writing and signed by an authorized representative of ZF.

11.129
About ZF Friedrichshafen AG
ZF is a global technology company and supplies systems for passenger cars, commercial vehicles and industrial technology, enabling the next generation of mobility. ZF allows vehicles to see, think and act. In the four technology domains Vehicle Motion Control, Integrated Safety, Automated Driving, and Electric Mobility, ZF offers comprehensive solutions for established vehicle manufacturers and newly emerging transport and mobility service providers. ZF electrifies different kinds of vehicles. With its products, the company contributes to reducing emissions and protecting the climate.

ZF, which acquired WABCO Holdings Inc. on May 29, 2020, now has 160,000 employees worldwide with approximately 260 locations in 41 countries. In 2019, the two then-independent companies achieved sales of €36.5 billion (ZF) and $3.4 billion (WABCO). For more information, visit: www.wabco-na.com
© 2021 ZF CV Systems North America LLC - All rights reserved - SP1375 / 2.2021 For further product details contact your distributor or the WABCO Customer Care Center at 855-228-3203.

11.130
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0012

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This warranty applies only to the cab tubular support and mounting structures and other structural components of the cab of the vehicle model, as identified in the Pierce
specifications for the Fire and Rescue Apparatus.

This warranty does not apply to damage caused by corrosion.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:

Ten (10) Year Structural Integrity
Custom Cab
Ten (10) Years
- or -
100,000 Miles
Warranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

The Pierce Custom Cab shall be free from structural failures caused by defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

11.131

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

Fire and Rescue Apparatus
Coverage:

Ten (10) Year Pro-Rated Paint and Corrosion
Cab
Ten (10) Years Warranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

Exterior surfaces of the cab painted by Pierce shall be free from blistering, peeling, corrosion or any other adhesion defect caused by defective manufacturing methods or paint material selection.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0055

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty is applicable to the vehicle in the following percentage costs of warranty repair, if any:

Topcoat Durability & Appearance: Gloss, Color Retention & Cracking
0-72 months 100%
73-96 months 50%
97-120 months 25%
Integrity of Coating System: Adhesion, Blistering/Bubbling 0-36 months 100%
37-84 months 50%
85-120 months 25%
Corrosion: Dissimilar Metal and Crevice
0-36 months 100%
37-48 months 50%
49-72 months 25%
73-120 months 10%
Corrosion Perforation
0-120 months 100%
This limited warranty applies only to exterior paint. Paint on the vehicle's interior is warranted only under the Pierce Basic One Year Limited Warranty.

Items not covered by this warranty include:
(a) Damage from lack of maintenance and cleaning (proper cleaning and maintenance procedures are detailed in the Pierce operation and maintenance manual).
(b) UV paint fade.
(c) Any cab not manufactured by Pierce.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

11.132
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0014

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty applies to all of the control modules for the Command Zone system, including the full color graphic displays. Related wire harnesses, cables and connectors are not covered under this limited warranty and are instead covered under the Pierce One Year Basic Apparatus Limited Warranty.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:

Five (5) Year Material and Workmanship
Command Zone Electronics
Five (5) Years Warranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

Command Zone control modules shall be free from failures caused by defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

11.133
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 1/11/2011 WA0188

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty does not apply to related wire
harnesses, cables, and connectors, which are covered by the Pierce one (1) year basic apparatus limited warranty.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:
54 Months Material and Workmanship
Camera System
Fifty - Four (54) months Warranty Period
Ends After:

Warranty Begins: The date of delivery.

This limited warranty covers repairs to correct any defect related to materials or workmanship of the Sharpvision
camera system installed on the apparatus occuring during the warranty period.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

11.134
Fire and Rescue Apparatus
Coverage:

Ten (10) Year Material and Workmanship
Pierce 12V LED Strip Light
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

This limited warranty covers repairs to correct any defect related to materials or workmanship of the Pierce 12V LED strip lights installed on the apparatus occuring during the warranty period.

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty does not apply to related wire
harnesses, cables, and connectors, which are covered by the Pierce one (1) year basic apparatus limited warranty.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Ten (10) Year Warranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 7/5/2011 WA0203
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

11.135

NEW PRODUCT WARRANTY

PARTICIPATING OEM SALES

DISTRIBUTOR SALES

LIMITED WARRANTY ON NEW ALLISON AUTOMATIC TRANSMISSIONS

USED IN EMERGENCY VEHICLE APPLICATIONS
Allison Transmission will provide for repairs or replacement, at its option, during the warranty period of each new Allison transmission listed below that is installed in an Emergency Vehicle in accordance with the following terms, conditions, and limitations.

WHAT IS COVERED
 WARRANTY APPLIES — This warranty is for new Allison transmission models listed below installed in an Emergency Vehicle and is provided to the original and any subsequent owner(s) of the vehicle during the warranty period.  REPAIRS COVERED — The warranty covers repairs or replacement, at Allison Transmission’s option, to correct any transmission malfunction resulting from defects in material or workmanship occurring during the warranty period. Needed repairs or replacements will be performed using the method Allison Transmission determines most appropriate under the circumstances.  TOWING — Towing is covered to the nearest Allison Transmission Distributor or authorized Dealer only when necessary to prevent further damage to your transmission.
 PAYMENT TERMS — Warranty repairs, including parts and labor, will be covered per the schedule shown in the chart contained in section “APPLICABLE MODELS, WARRANTY LIMITATIONS, AND ADJUSTMENT SCHEDULE.”  OBTAINING REPAIRS — To obtain warranty repairs, take the vehicle to any Allison Transmission Distributor or authorized Dealer within a reasonable amount of time and request the needed repairs. A reasonable amount of time must be allowed for the Distributor or Dealer to perform necessary repairs.
 TRANSMISSION REMOVAL AND REINSTALLATION — Labor costs for the removal and re-installation of the transmission, when necessary to make a warranty repair, are covered by this warranty.  WARRANTY PERIOD — The warranty period for all coverages shall begin on the date the transmission is delivered to the first retail purchaser, with the following exception:

Demonstration Service - A transmission in a new truck or bus may be demonstrated to a total of 5000 miles (8000 kilometers).

If the vehicle is within this limit when sold to a retail purchaser, the warranty start date is the date of purchase. Normal warranty services are applicable to the demonstrating Dealer. Should the truck or bus be sold to a retail purchaser after these limits are reached, the warranty period will begin on the date the vehicle was first placed in demonstration service and the purchaser will be entitled to the remaining warranty.

APPLICABLE MODELS, WARRANTY LIMITATIONS, AND ADJUSTMENT SCHEDULE

WARRANTY LIMITATIONS
(Whichever occurs first)

ADJUSTMENT CHARGE TO BE

APPLICABLE PAID BY THE CUSTOMER
MODELS
Months
Transmission Miles
Or Kilometers Parts Labor
MT, MD
3000, 3200, 3500, 3700 0–24 No Limit No Charge No Charge HT with Hydraulic Controls 0–24 No Limit No Charge No Charge AT, 1000 Series, 2000 Series,
2400 Series 0–36 No Limit No Charge No Charge
HT with Electronic Controls 0–60 No Limit No Charge No Charge HD
1000 EVS, 2100 EVS, 2200 EVS
2350 EVS, 2500 EVS, 2550 EVS,
3000 EVS, 3500 EVS, 4000,
4000 EVS, 4500, 4500 EVS, 4700,
4700 EVS, 4800, 4800 EVS
0–60 No Limit No Charge No Charge

Page 1 of 2 ends