Generate Medical Waste: Not reported
Treat Haz Waste: Not reported
Generate Haz Waste: Y
Subject To APSA: Not reported
Own Or Operate UST: Not reported
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 220
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
2634(e), 2641(h)
Violation Citation: Emergency Response Plan is not available/complete. 25289(b); 2632(b), Violation: UST ER RESPONSE PLAN NOT COMPLETE/AVAIL
Violation Code: 6HV3108
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: All permit operating conditions not met. 25284; 2712 Violation: ALL OPERATING CONDITIONS NOT MET
Violation Code: 6HV3158
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Violations Active Permits:
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
Other Information: PAINT WASTE
Name: WASTE 223 UNSPEC OIL CONTAINING WASTE
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
Other Information: DIESEL FUEL & WATER
Name: WASTE 223 UNSPEC OIL CONTAINING WASTE
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: OXYGEN GAS
Case Number: 7782-44-7
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: ACUTE
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 221
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.34(f)
Violation Citation: Failed to properly label/date hazardous waste container &/or tank.
Violation: HAZWASTE TANK/CONTAINER W/O LABEL/DATE
Violation Code: 6HV0227
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
SQH:66273.11(a); LQH: 66273.31(a)
Violation Citation: Disposal of universal waste to an unauthorized point. 25189.5(a); Violation: ILLEGAL DISPOSAL OF UNIVERSAL WASTE
Violation Code: 6HV0307
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: Did not have adequate employee training program 2732 &/or 25504( c) Violation: EMPLOYEE TRAINING NOT ADEQUATE
Violation Code: 6HV1015
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
DO inspection reports not onsite 2715 (c)(d)(e)
Violation Citation: Designated Operator monthly inspection not conducted or incomplete; or Violation: NO D.O INSPECTION/INCOMPL;NO REPORTS
Violation Code: 6HV3192
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 222
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Violation: ALL OPERATING CONDITIONS NOT MET
Violation Code: 6HV3158
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25284.1; 2637(a)
Violation Citation: Secondary containment testing not conducted at 6months/36 months.
Violation: 2NDRY CONT TEST NOT DONE (6/36 MOS.)
Violation Code: 6HV3112
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
2634(e), 2641(h)
Violation Citation: Emergency Response Plan is not available/complete. 25289(b); 2632(b), Violation: UST ER RESPONSE PLAN NOT COMPLETE/AVAIL
Violation Code: 6HV3108
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
(d), 2634(d), 2641(h), 2711(a)(9)
Violation Citation: Monitoring procedures not available/complete/submitted to HMD 2632(b)& Violation: MONITORING PROCEDURES NOT AVAIL/TO HMD
Violation Code: 6HV3107
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25292.2(a), 25299.33; 2809
Violation Citation: Current evidence of financial responsibility not available.
Violation: NO CURRENT FINANCIAL RESPONSIBILITY
Violation Code: 6HV3105
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25286(a); 2712(i); 68.1003
Violation Citation: Current Operating Permit not available at facility. 25284(a), Violation: OPER. PERMIT NOT CURRENT/ONSITE
Violation Code: 6HV3102
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.40(a)
waste manifest from the TSD facility on site for review. CCR Violation Citation: Generator has not maintained the required signed copy of the hazardous Violation: NO TSDF SIGNED MANIFEST ONSITE
Violation Code: 6HV0138
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 223
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Violation Citation: HMBP is incomplete/inadequate/not amended to reflect changes. 25504, Violation: HMBP INCOMPLETE/NOT AMENDED
Violation Code: 6HV1014
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25505(a)(2)
complete information for emergency response agencies. HSC 25509(a)(5) Violation Citation: Business Plan does not have a site map which provides sufficient or Violation: HMBP: INADEQUATE SITE MAP
Violation Code: 6HV1009
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66265.16(d)&(e)
with requirements for current and former employees. CCR Violation Citation: Personnel training records are not maintained to document compliance Violation: TRAINING RECORDS UNAVAILABLE
Violation Code: 6HV0401
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
explosion or release. CCR 66265.31
Violation Citation: Facility not maintained &/operated to minimize possibility of fire, Violation: FIRE/EXPLOSION/RELEASE NOT MINIMIZED
Violation Code: 6HV0207
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
identification number. CCR 66262.12(a)
Violation Citation: Generator of hazardous waste has not obtained/maintained an EPA Violation: EPA ID NUMBER NOT OBTAINED/MAINTAINED
Violation Code: 6HV0132
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: All permit operating conditions not met. 25284; 2712 SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 224
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Permit Number: 120813
Activity: ACTIVE
Violation Citation: Did not have adequate employee training program 2732 &/or 25504( c) Violation: EMPLOYEE TRAINING NOT ADEQUATE
Violation Code: 6HV1015
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
plan. HSC 25503.5(a)
Violation Citation: Hazardous materials handler has not established/implemented a business Violation: HMBP NOT ESTABISHED/IMPLEMENTED.
Violation Code: 6HV1002
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
covered containers or bins. 118280(b)
Violation Citation: Did not containerize and place red bags in rigid, leak resistant, and Violation: RED BAGS NOT CONTAINERIZED
Violation Code: 6HV4212
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.34(f)
Violation Citation: Failed to properly label/date hazardous waste container &/or tank.
Violation: HAZWASTE TANK/CONTAINER W/O LABEL/DATE
Violation Code: 6HV0227
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25505(a)(2) &/or 25509(a); 25505(b); 19 CCR 2729
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 225
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T001
UST:
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
waste as defined by law. CCR 66262.11 & 66260.200( c)
Violation Citation: Generator of a waste has not determined if that waste is a hazardous Violation: WASTE DETERMINATION NOT MADE
Violation Code: 6HV0304
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
waste regulations. CCR 66265.16(a)&(b)
Violation Citation: Personnel training is not adequate to ensure compliance with hazardous Violation: TRAINING PROGRAM NOT ADEQUATE
Violation Code: 6HV0402
Inspection Date: 06/13/2005
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
waste as defined by law. CCR 66262.11 & 66260.200( c)
Violation Citation: Generator of a waste has not determined if that waste is a hazardous Violation: WASTE DETERMINATION NOT MADE
Violation Code: 6HV0304
Inspection Date: 06/13/2005
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 07/10/2007
Update Date: 11/02/2012
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 226
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
APN: 381-050-37-00
EPA Id Number: CAL000040308
Business Type: 6HK23
Permit Number: 120813
City,State,Zip: SANTEE, CA 92071
Address: 9000 COTTONWOOD AV
Name: SD CNTY LAS COLINAS DETENTION FACILITY
MONITORS: INTERSTITIAL.
UST Monitor Method: DW TANK DW SUCTION AND/ OR GRAVITY PIPING WITH INTERSTITIAL Monitor Code: 21
Delivery System: SUCTION
Pipe Type: DOUBLE WALL
Year Installed: 1998-01-01 00:00:00
Remove Close Date: Not reported
Reg Status: ACTIVE
Other Content Info: DIESEL
UST Contents: DIESEL
Capacity Gallons: 1000
Additional Id: NT2127 DIESEL; RT2713
Tank Type: DOUBLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T003
TANK TEST ANNUAL (EXEMPT IF UST < 551 GAL), PIPE TEST TRIENNIALLY UST Monitor Method: SW TANK SW SUCTION PIPE W/DAILY RECONCILIATION OR WEEKLY GAUGING:
Monitor Code: 06
Delivery System: SUCTION
Pipe Type: SINGLE WALL
Year Installed: 1978-01-01 00:00:00
Remove Close Date: 1998-10-20 00:00:00
Reg Status: REMOVED
Other Content Info: DIESEL
UST Contents: DIESEL
Capacity Gallons: 1000
Additional Id: LC-1 (NT2127)
Tank Type: SINGLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T002
TANK TEST ANNUAL (EXEMPT IF UST < 551 GAL), PIPE TEST TRIENNIALLY UST Monitor Method: SW TANK SW SUCTION PIPE W/DAILY RECONCILIATION OR WEEKLY GAUGING:
Monitor Code: 06
Delivery System: GRAVITY
Pipe Type: SINGLE WALL
Year Installed: 1983-01-01 00:00:00
Remove Close Date: 1998-10-20 00:00:00
Reg Status: REMOVED
Other Content Info: WASTE OIL
UST Contents: Not reported
Capacity Gallons: 550
Additional Id: LC-2
Tank Type: SINGLE WALL
Permit Number: 120813
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 227
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Case Number: 68476-34-6
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: CHRONIC
Material Waste: Material
Other Information: Not reported
Name: DIESEL
Case Number: 68476-34-6
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: CARBON DIOXIDE/ ARGON GAS MIXTURE
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: ACUTE
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: ARGON GAS
Case Number: 7440-37-1
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: ACETYLENE GAS
Case Number: 74-86-2
Update Date: 11/02/2012
Permit Number: 120813
Inventory Active Permits (not SQG Medical):
Generate Medical Waste: Not reported
Treat Haz Waste: Not reported
Generate Haz Waste: Y
Subject To APSA: Not reported
Own Or Operate UST: Not reported
Handle Regulated Hazmat: Y
UST Owner: COUNTY OF SAN DIEGO/GEN SVCS
Facility Mailing Zip: 92123-1219
Facility Mailing State: CA
Facility Mailing City: SAN DIEGO
Facility Mailing Address: 5560 OVERLAND AVE 04TH FLR #410 Facility Owner: COUNTY OF SAN DIEGO
Date Last Updated: 11/02/2012
Permit Expiration: 06/30/2013
Permit Status: OPEN
Facility Telephone: 619-258-3262
Last HMMD Inspection: 08/14/2012
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 228
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Violation Citation: Emergency Response Plan is not available/complete. 25289(b); 2632(b), Violation: UST ER RESPONSE PLAN NOT COMPLETE/AVAIL
Violation Code: 6HV3108
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: All permit operating conditions not met. 25284; 2712 Violation: ALL OPERATING CONDITIONS NOT MET
Violation Code: 6HV3158
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Violations Active Permits:
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
Other Information: PAINT WASTE
Name: WASTE 223 UNSPEC OIL CONTAINING WASTE
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
Other Information: DIESEL FUEL & WATER
Name: WASTE 223 UNSPEC OIL CONTAINING WASTE
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: OXYGEN GAS
Case Number: 7782-44-7
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: ACUTE
Material Waste: Material
Other Information: LATEX PAINT
Name: LATEX PAINT
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: FIRE
Material Waste: Material
Other Information: UNDERGROUND TANK 120813 T003 DIESEL
Name: DIESEL
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 229
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
SQH:66273.11(a); LQH: 66273.31(a)
Violation Citation: Disposal of universal waste to an unauthorized point. 25189.5(a); Violation: ILLEGAL DISPOSAL OF UNIVERSAL WASTE
Violation Code: 6HV0307
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: Did not have adequate employee training program 2732 &/or 25504( c) Violation: EMPLOYEE TRAINING NOT ADEQUATE
Violation Code: 6HV1015
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
DO inspection reports not onsite 2715 (c)(d)(e)
Violation Citation: Designated Operator monthly inspection not conducted or incomplete; or Violation: NO D.O INSPECTION/INCOMPL;NO REPORTS
Violation Code: 6HV3192
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
2634(e), 2641(h)
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 230
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
2634(e), 2641(h)
Violation Citation: Emergency Response Plan is not available/complete. 25289(b); 2632(b), Violation: UST ER RESPONSE PLAN NOT COMPLETE/AVAIL
Violation Code: 6HV3108
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
(d), 2634(d), 2641(h), 2711(a)(9)
Violation Citation: Monitoring procedures not available/complete/submitted to HMD 2632(b)& Violation: MONITORING PROCEDURES NOT AVAIL/TO HMD
Violation Code: 6HV3107
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25292.2(a), 25299.33; 2809
Violation Citation: Current evidence of financial responsibility not available.
Violation: NO CURRENT FINANCIAL RESPONSIBILITY
Violation Code: 6HV3105
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25286(a); 2712(i); 68.1003
Violation Citation: Current Operating Permit not available at facility. 25284(a), Violation: OPER. PERMIT NOT CURRENT/ONSITE
Violation Code: 6HV3102
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.40(a)
waste manifest from the TSD facility on site for review. CCR Violation Citation: Generator has not maintained the required signed copy of the hazardous Violation: NO TSDF SIGNED MANIFEST ONSITE
Violation Code: 6HV0138
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.34(f)
Violation Citation: Failed to properly label/date hazardous waste container &/or tank.
Violation: HAZWASTE TANK/CONTAINER W/O LABEL/DATE
Violation Code: 6HV0227
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 231
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Violation Code: 6HV1009
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66265.16(d)&(e)
with requirements for current and former employees. CCR Violation Citation: Personnel training records are not maintained to document compliance Violation: TRAINING RECORDS UNAVAILABLE
Violation Code: 6HV0401
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
explosion or release. CCR 66265.31
Violation Citation: Facility not maintained &/operated to minimize possibility of fire, Violation: FIRE/EXPLOSION/RELEASE NOT MINIMIZED
Violation Code: 6HV0207
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
identification number. CCR 66262.12(a)
Violation Citation: Generator of hazardous waste has not obtained/maintained an EPA Violation: EPA ID NUMBER NOT OBTAINED/MAINTAINED
Violation Code: 6HV0132
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: All permit operating conditions not met. 25284; 2712 Violation: ALL OPERATING CONDITIONS NOT MET
Violation Code: 6HV3158
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25284.1; 2637(a)
Violation Citation: Secondary containment testing not conducted at 6months/36 months.
Violation: 2NDRY CONT TEST NOT DONE (6/36 MOS.)
Violation Code: 6HV3112
Inspection Date: 01/30/2003
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 232
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Violation Citation: Hazardous materials handler has not established/implemented a business Violation: HMBP NOT ESTABISHED/IMPLEMENTED.
Violation Code: 6HV1002
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
covered containers or bins. 118280(b)
Violation Citation: Did not containerize and place red bags in rigid, leak resistant, and Violation: RED BAGS NOT CONTAINERIZED
Violation Code: 6HV4212
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.34(f)
Violation Citation: Failed to properly label/date hazardous waste container &/or tank.
Violation: HAZWASTE TANK/CONTAINER W/O LABEL/DATE
Violation Code: 6HV0227
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25505(a)(2) &/or 25509(a); 25505(b); 19 CCR 2729
Violation Citation: HMBP is incomplete/inadequate/not amended to reflect changes. 25504, Violation: HMBP INCOMPLETE/NOT AMENDED
Violation Code: 6HV1014
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25505(a)(2)
complete information for emergency response agencies. HSC 25509(a)(5) Violation Citation: Business Plan does not have a site map which provides sufficient or Violation: HMBP: INADEQUATE SITE MAP
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 233
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Activity: ACTIVE
waste as defined by law. CCR 66262.11 & 66260.200( c)
Violation Citation: Generator of a waste has not determined if that waste is a hazardous Violation: WASTE DETERMINATION NOT MADE
Violation Code: 6HV0304
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
waste regulations. CCR 66265.16(a)&(b)
Violation Citation: Personnel training is not adequate to ensure compliance with hazardous Violation: TRAINING PROGRAM NOT ADEQUATE
Violation Code: 6HV0402
Inspection Date: 06/13/2005
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
waste as defined by law. CCR 66262.11 & 66260.200( c)
Violation Citation: Generator of a waste has not determined if that waste is a hazardous Violation: WASTE DETERMINATION NOT MADE
Violation Code: 6HV0304
Inspection Date: 06/13/2005
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: Did not have adequate employee training program 2732 &/or 25504( c) Violation: EMPLOYEE TRAINING NOT ADEQUATE
Violation Code: 6HV1015
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
plan. HSC 25503.5(a)
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 234
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Delivery System: SUCTION
Pipe Type: DOUBLE WALL
Year Installed: 1998-01-01 00:00:00
Remove Close Date: Not reported
Reg Status: ACTIVE
Other Content Info: DIESEL
UST Contents: DIESEL
Capacity Gallons: 1000
Additional Id: NT2127 DIESEL; RT2713
Tank Type: DOUBLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T003
TANK TEST ANNUAL (EXEMPT IF UST < 551 GAL), PIPE TEST TRIENNIALLY UST Monitor Method: SW TANK SW SUCTION PIPE W/DAILY RECONCILIATION OR WEEKLY GAUGING:
Monitor Code: 06
Delivery System: SUCTION
Pipe Type: SINGLE WALL
Year Installed: 1978-01-01 00:00:00
Remove Close Date: 1998-10-20 00:00:00
Reg Status: REMOVED
Other Content Info: DIESEL
UST Contents: DIESEL
Capacity Gallons: 1000
Additional Id: LC-1 (NT2127)
Tank Type: SINGLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T002
TANK TEST ANNUAL (EXEMPT IF UST < 551 GAL), PIPE TEST TRIENNIALLY UST Monitor Method: SW TANK SW SUCTION PIPE W/DAILY RECONCILIATION OR WEEKLY GAUGING:
Monitor Code: 06
Delivery System: GRAVITY
Pipe Type: SINGLE WALL
Year Installed: 1983-01-01 00:00:00
Remove Close Date: 1998-10-20 00:00:00
Reg Status: REMOVED
Other Content Info: WASTE OIL
UST Contents: Not reported
Capacity Gallons: 550
Additional Id: LC-2
Tank Type: SINGLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T001
UST:
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 235
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
Other Information: PHOTO PROCESSING FIXER/DEVELOPER
Name: WASTE 541 PHOTOCHEM/PHOTOPROC WASTE
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 152208
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
Other Information: RED BAGS
Name: WASTE 901 INFECTIOUS WASTE, GENERAL
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 152208
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
Other Information: Not reported
Name: WASTE 902 INFECTIOUS WASTE, SHARPS
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 152208
Inventory Active Permits (SQG Medical):
Generate Medical Waste: Y
Treat Haz Waste: Not reported
Generate Haz Waste: Not reported
Subject To APSA: Not reported
Own Or Operate UST: Not reported
Handle Regulated Hazmat: Not reported
UST Owner: Not reported
Facility Mailing Zip: 92123
Facility Mailing State: CA
Facility Mailing City: SAN DIEGO
Facility Mailing Address: 8525 GIBBS DR #303
Facility Owner: SHERIFF’S DEPT MEDICAL SERVICES
Date Last Updated: 11/02/2012
Permit Expiration: 03/31/2013
Permit Status: OPEN
Facility Telephone: 619-258-3200
Last HMMD Inspection: 07/14/2011
APN: 381-050-51-00
EPA Id Number: Not reported
Business Type: 6HK10
Permit Number: 152208
City,State,Zip: SANTEE, CA 92071
Address: 9000 COTTONWOOD AV
Name: SD COUNTY LAS COLINAS DETENTION FACILITY
MONITORS: INTERSTITIAL.
UST Monitor Method: DW TANK DW SUCTION AND/ OR GRAVITY PIPING WITH INTERSTITIAL Monitor Code: 21
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 236
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: ACUTE
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: ARGON GAS
Case Number: 7440-37-1
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: ACETYLENE GAS
Case Number: 74-86-2
Update Date: 11/02/2012
Permit Number: 120813
Inventory Active Permits (not SQG Medical):
Generate Medical Waste: Not reported
Treat Haz Waste: Not reported
Generate Haz Waste: Y
Subject To APSA: Not reported
Own Or Operate UST: Y
Handle Regulated Hazmat: Y
UST Owner: COUNTY OF SAN DIEGO/GEN SVCS
Facility Mailing Zip: 92123-1219
Facility Mailing State: CA
Facility Mailing City: SAN DIEGO
Facility Mailing Address: 5560 OVERLAND AVE 04TH FLR #410 Facility Owner: COUNTY OF SAN DIEGO
Date Last Updated: 11/02/2012
Permit Expiration: 06/30/2013
Permit Status: OPEN
Facility Telephone: 619-258-3262
Last HMMD Inspection: 08/14/2012
APN: 381-050-37-00
EPA Id Number: CAL000040308
Business Type: 6HK23
Permit Number: 120813
City,State,Zip: SANTEE, CA 92071
Address: 9000 COTTONWOOD AV
Name: SD CNTY LAS COLINAS DETENTION FACILITY
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 07/14/2011
Update Date: 11/02/2012
Permit Number: 152208
Violations Active Permits:
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 237
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Other Information: PAINT WASTE
Name: WASTE 223 UNSPEC OIL CONTAINING WASTE
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
Other Information: DIESEL FUEL & WATER
Name: WASTE 223 UNSPEC OIL CONTAINING WASTE
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: OXYGEN GAS
Case Number: 7782-44-7
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: ACUTE
Material Waste: Material
Other Information: LATEX PAINT
Name: LATEX PAINT
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: FIRE
Material Waste: Material
Other Information: UNDERGROUND TANK 120813 T003 DIESEL
Name: DIESEL
Case Number: 68476-34-6
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: CHRONIC
Material Waste: Material
Other Information: Not reported
Name: DIESEL
Case Number: 68476-34-6
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: CARBON DIOXIDE/ ARGON GAS MIXTURE
Case Number: Not reported
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 238
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: Did not have adequate employee training program 2732 &/or 25504( c) Violation: EMPLOYEE TRAINING NOT ADEQUATE
Violation Code: 6HV1015
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
DO inspection reports not onsite 2715 (c)(d)(e)
Violation Citation: Designated Operator monthly inspection not conducted or incomplete; or Violation: NO D.O INSPECTION/INCOMPL;NO REPORTS
Violation Code: 6HV3192
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
2634(e), 2641(h)
Violation Citation: Emergency Response Plan is not available/complete. 25289(b); 2632(b), Violation: UST ER RESPONSE PLAN NOT COMPLETE/AVAIL
Violation Code: 6HV3108
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: All permit operating conditions not met. 25284; 2712 Violation: ALL OPERATING CONDITIONS NOT MET
Violation Code: 6HV3158
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Violations Active Permits:
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 239
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25292.2(a), 25299.33; 2809
Violation Citation: Current evidence of financial responsibility not available.
Violation: NO CURRENT FINANCIAL RESPONSIBILITY
Violation Code: 6HV3105
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25286(a); 2712(i); 68.1003
Violation Citation: Current Operating Permit not available at facility. 25284(a), Violation: OPER. PERMIT NOT CURRENT/ONSITE
Violation Code: 6HV3102
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.40(a)
waste manifest from the TSD facility on site for review. CCR Violation Citation: Generator has not maintained the required signed copy of the hazardous Violation: NO TSDF SIGNED MANIFEST ONSITE
Violation Code: 6HV0138
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.34(f)
Violation Citation: Failed to properly label/date hazardous waste container &/or tank.
Violation: HAZWASTE TANK/CONTAINER W/O LABEL/DATE
Violation Code: 6HV0227
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
SQH:66273.11(a); LQH: 66273.31(a)
Violation Citation: Disposal of universal waste to an unauthorized point. 25189.5(a); Violation: ILLEGAL DISPOSAL OF UNIVERSAL WASTE
Violation Code: 6HV0307
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 240
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Violation: FIRE/EXPLOSION/RELEASE NOT MINIMIZED
Violation Code: 6HV0207
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
identification number. CCR 66262.12(a)
Violation Citation: Generator of hazardous waste has not obtained/maintained an EPA Violation: EPA ID NUMBER NOT OBTAINED/MAINTAINED
Violation Code: 6HV0132
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: All permit operating conditions not met. 25284; 2712 Violation: ALL OPERATING CONDITIONS NOT MET
Violation Code: 6HV3158
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25284.1; 2637(a)
Violation Citation: Secondary containment testing not conducted at 6months/36 months.
Violation: 2NDRY CONT TEST NOT DONE (6/36 MOS.)
Violation Code: 6HV3112
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
2634(e), 2641(h)
Violation Citation: Emergency Response Plan is not available/complete. 25289(b); 2632(b), Violation: UST ER RESPONSE PLAN NOT COMPLETE/AVAIL
Violation Code: 6HV3108
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
(d), 2634(d), 2641(h), 2711(a)(9)
Violation Citation: Monitoring procedures not available/complete/submitted to HMD 2632(b)& Violation: MONITORING PROCEDURES NOT AVAIL/TO HMD
Violation Code: 6HV3107
Inspection Date: 01/30/2003
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 241
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.34(f)
Violation Citation: Failed to properly label/date hazardous waste container &/or tank.
Violation: HAZWASTE TANK/CONTAINER W/O LABEL/DATE
Violation Code: 6HV0227
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25505(a)(2) &/or 25509(a); 25505(b); 19 CCR 2729
Violation Citation: HMBP is incomplete/inadequate/not amended to reflect changes. 25504, Violation: HMBP INCOMPLETE/NOT AMENDED
Violation Code: 6HV1014
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25505(a)(2)
complete information for emergency response agencies. HSC 25509(a)(5) Violation Citation: Business Plan does not have a site map which provides sufficient or Violation: HMBP: INADEQUATE SITE MAP
Violation Code: 6HV1009
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66265.16(d)&(e)
with requirements for current and former employees. CCR Violation Citation: Personnel training records are not maintained to document compliance Violation: TRAINING RECORDS UNAVAILABLE
Violation Code: 6HV0401
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
explosion or release. CCR 66265.31
Violation Citation: Facility not maintained &/operated to minimize possibility of fire, SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 242
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Activity: ACTIVE
waste regulations. CCR 66265.16(a)&(b)
Violation Citation: Personnel training is not adequate to ensure compliance with hazardous Violation: TRAINING PROGRAM NOT ADEQUATE
Violation Code: 6HV0402
Inspection Date: 06/13/2005
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
waste as defined by law. CCR 66262.11 & 66260.200( c)
Violation Citation: Generator of a waste has not determined if that waste is a hazardous Violation: WASTE DETERMINATION NOT MADE
Violation Code: 6HV0304
Inspection Date: 06/13/2005
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: Did not have adequate employee training program 2732 &/or 25504( c) Violation: EMPLOYEE TRAINING NOT ADEQUATE
Violation Code: 6HV1015
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
plan. HSC 25503.5(a)
Violation Citation: Hazardous materials handler has not established/implemented a business Violation: HMBP NOT ESTABISHED/IMPLEMENTED.
Violation Code: 6HV1002
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
covered containers or bins. 118280(b)
Violation Citation: Did not containerize and place red bags in rigid, leak resistant, and Violation: RED BAGS NOT CONTAINERIZED
Violation Code: 6HV4212
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
and/or not onsite. 2715(f)
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 243
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Pipe Type: SINGLE WALL
Year Installed: 1978-01-01 00:00:00
Remove Close Date: 1998-10-20 00:00:00
Reg Status: REMOVED
Other Content Info: DIESEL
UST Contents: DIESEL
Capacity Gallons: 1000
Additional Id: LC-1 (NT2127)
Tank Type: SINGLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T002
TANK TEST ANNUAL (EXEMPT IF UST < 551 GAL), PIPE TEST TRIENNIALLY UST Monitor Method: SW TANK SW SUCTION PIPE W/DAILY RECONCILIATION OR WEEKLY GAUGING:
Monitor Code: 06
Delivery System: GRAVITY
Pipe Type: SINGLE WALL
Year Installed: 1983-01-01 00:00:00
Remove Close Date: 1998-10-20 00:00:00
Reg Status: REMOVED
Other Content Info: WASTE OIL
UST Contents: Not reported
Capacity Gallons: 550
Additional Id: LC-2
Tank Type: SINGLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T001
UST:
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
waste as defined by law. CCR 66262.11 & 66260.200( c)
Violation Citation: Generator of a waste has not determined if that waste is a hazardous Violation: WASTE DETERMINATION NOT MADE
Violation Code: 6HV0304
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 244
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Hazardous Categories 2: Not reported
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: ACETYLENE GAS
Case Number: 74-86-2
Update Date: 11/02/2012
Permit Number: 120813
Inventory Active Permits (not SQG Medical):
Generate Medical Waste: Not reported
Treat Haz Waste: Not reported
Generate Haz Waste: Y
Subject To APSA: Not reported
Own Or Operate UST: Not reported
Handle Regulated Hazmat: Y
UST Owner: COUNTY OF SAN DIEGO/GEN SVCS
Facility Mailing Zip: 92123-1219
Facility Mailing State: CA
Facility Mailing City: SAN DIEGO
Facility Mailing Address: 5560 OVERLAND AVE 04TH FLR #410 Facility Owner: COUNTY OF SAN DIEGO
Date Last Updated: 11/02/2012
Permit Expiration: 06/30/2013
Permit Status: OPEN
Facility Telephone: 619-258-3262
Last HMMD Inspection: 08/14/2012
APN: 381-050-37-00
EPA Id Number: CAL000040308
Business Type: 6HK23
Permit Number: 120813
City,State,Zip: SANTEE, CA 92071
Address: 9000 COTTONWOOD AV
Name: SD CNTY LAS COLINAS DETENTION FACILITY
MONITORS: INTERSTITIAL.
UST Monitor Method: DW TANK DW SUCTION AND/ OR GRAVITY PIPING WITH INTERSTITIAL Monitor Code: 21
Delivery System: SUCTION
Pipe Type: DOUBLE WALL
Year Installed: 1998-01-01 00:00:00
Remove Close Date: Not reported
Reg Status: ACTIVE
Other Content Info: DIESEL
UST Contents: DIESEL
Capacity Gallons: 1000
Additional Id: NT2127 DIESEL; RT2713
Tank Type: DOUBLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T003
TANK TEST ANNUAL (EXEMPT IF UST < 551 GAL), PIPE TEST TRIENNIALLY UST Monitor Method: SW TANK SW SUCTION PIPE W/DAILY RECONCILIATION OR WEEKLY GAUGING:
Monitor Code: 06
Delivery System: SUCTION
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 245
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: OXYGEN GAS
Case Number: 7782-44-7
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: ACUTE
Material Waste: Material
Other Information: LATEX PAINT
Name: LATEX PAINT
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: FIRE
Material Waste: Material
Other Information: UNDERGROUND TANK 120813 T003 DIESEL
Name: DIESEL
Case Number: 68476-34-6
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: CHRONIC
Material Waste: Material
Other Information: Not reported
Name: DIESEL
Case Number: 68476-34-6
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: CARBON DIOXIDE/ ARGON GAS MIXTURE
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: ACUTE
Hazardous Categories 1: PRESSURE RELEASE
Material Waste: Material
Other Information: Not reported
Name: ARGON GAS
Case Number: 7440-37-1
Update Date: 11/02/2012
Permit Number: 120813
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 246
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Violation Citation: Did not have adequate employee training program 2732 &/or 25504( c) Violation: EMPLOYEE TRAINING NOT ADEQUATE
Violation Code: 6HV1015
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
DO inspection reports not onsite 2715 (c)(d)(e)
Violation Citation: Designated Operator monthly inspection not conducted or incomplete; or Violation: NO D.O INSPECTION/INCOMPL;NO REPORTS
Violation Code: 6HV3192
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
2634(e), 2641(h)
Violation Citation: Emergency Response Plan is not available/complete. 25289(b); 2632(b), Violation: UST ER RESPONSE PLAN NOT COMPLETE/AVAIL
Violation Code: 6HV3108
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: All permit operating conditions not met. 25284; 2712 Violation: ALL OPERATING CONDITIONS NOT MET
Violation Code: 6HV3158
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Violations Active Permits:
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
Other Information: PAINT WASTE
Name: WASTE 223 UNSPEC OIL CONTAINING WASTE
Case Number: Not reported
Update Date: 11/02/2012
Permit Number: 120813
Hazardous Categories 2: Not reported
Hazardous Categories 1: Not reported
Material Waste: Waste
Other Information: DIESEL FUEL & WATER
Name: WASTE 223 UNSPEC OIL CONTAINING WASTE
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 247
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Activity: ACTIVE
25286(a); 2712(i); 68.1003
Violation Citation: Current Operating Permit not available at facility. 25284(a), Violation: OPER. PERMIT NOT CURRENT/ONSITE
Violation Code: 6HV3102
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.40(a)
waste manifest from the TSD facility on site for review. CCR Violation Citation: Generator has not maintained the required signed copy of the hazardous Violation: NO TSDF SIGNED MANIFEST ONSITE
Violation Code: 6HV0138
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.34(f)
Violation Citation: Failed to properly label/date hazardous waste container &/or tank.
Violation: HAZWASTE TANK/CONTAINER W/O LABEL/DATE
Violation Code: 6HV0227
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 08/02/2011
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
SQH:66273.11(a); LQH: 66273.31(a)
Violation Citation: Disposal of universal waste to an unauthorized point. 25189.5(a); Violation: ILLEGAL DISPOSAL OF UNIVERSAL WASTE
Violation Code: 6HV0307
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 06/20/2006
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 248
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Violation Code: 6HV0135
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
identification number. CCR 66262.12(a)
Violation Citation: Generator of hazardous waste has not obtained/maintained an EPA Violation: EPA ID NUMBER NOT OBTAINED/MAINTAINED
Violation Code: 6HV0132
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: All permit operating conditions not met. 25284; 2712 Violation: ALL OPERATING CONDITIONS NOT MET
Violation Code: 6HV3158
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25284.1; 2637(a)
Violation Citation: Secondary containment testing not conducted at 6months/36 months.
Violation: 2NDRY CONT TEST NOT DONE (6/36 MOS.)
Violation Code: 6HV3112
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
2634(e), 2641(h)
Violation Citation: Emergency Response Plan is not available/complete. 25289(b); 2632(b), Violation: UST ER RESPONSE PLAN NOT COMPLETE/AVAIL
Violation Code: 6HV3108
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
(d), 2634(d), 2641(h), 2711(a)(9)
Violation Citation: Monitoring procedures not available/complete/submitted to HMD 2632(b)& Violation: MONITORING PROCEDURES NOT AVAIL/TO HMD
Violation Code: 6HV3107
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25292.2(a), 25299.33; 2809
Violation Citation: Current evidence of financial responsibility not available.
Violation: NO CURRENT FINANCIAL RESPONSIBILITY
Violation Code: 6HV3105
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 249
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Violation Code: 6HV0227
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
25505(a)(2) &/or 25509(a); 25505(b); 19 CCR 2729
Violation Citation: HMBP is incomplete/inadequate/not amended to reflect changes. 25504, Violation: HMBP INCOMPLETE/NOT AMENDED
Violation Code: 6HV1014
Inspection Date: 07/30/2008
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25505(a)(2)
complete information for emergency response agencies. HSC 25509(a)(5) Violation Citation: Business Plan does not have a site map which provides sufficient or Violation: HMBP: INADEQUATE SITE MAP
Violation Code: 6HV1009
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66265.16(d)&(e)
with requirements for current and former employees. CCR Violation Citation: Personnel training records are not maintained to document compliance Violation: TRAINING RECORDS UNAVAILABLE
Violation Code: 6HV0401
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
explosion or release. CCR 66265.31
Violation Citation: Facility not maintained &/operated to minimize possibility of fire, Violation: FIRE/EXPLOSION/RELEASE NOT MINIMIZED
Violation Code: 6HV0207
Inspection Date: 01/30/2003
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 250
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
waste as defined by law. CCR 66262.11 & 66260.200( c)
Violation Citation: Generator of a waste has not determined if that waste is a hazardous Violation: WASTE DETERMINATION NOT MADE
Violation Code: 6HV0304
Inspection Date: 06/13/2005
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
& 25160.2(b)(3)
onsite to document proper disposal of hazardous waste. CCR 66262.40(a) Violation Citation: Hazardous waste manifests/receipts for 3 years are not maintained Violation: MANIFESTS/RECEIPTS FOR 3 YEARS NOT ONSIT
Violation Code: 6HV0135
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
Violation Citation: Did not have adequate employee training program 2732 &/or 25504( c) Violation: EMPLOYEE TRAINING NOT ADEQUATE
Violation Code: 6HV1015
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
plan. HSC 25503.5(a)
Violation Citation: Hazardous materials handler has not established/implemented a business Violation: HMBP NOT ESTABISHED/IMPLEMENTED.
Violation Code: 6HV1002
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
covered containers or bins. 118280(b)
Violation Citation: Did not containerize and place red bags in rigid, leak resistant, and Violation: RED BAGS NOT CONTAINERIZED
Violation Code: 6HV4212
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 07/10/2007
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
66262.34(f)
Violation Citation: Failed to properly label/date hazardous waste container &/or tank.
Violation: HAZWASTE TANK/CONTAINER W/O LABEL/DATE
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 251
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
UST Name: UNDERGROUND TANK 120813 T002
TANK TEST ANNUAL (EXEMPT IF UST < 551 GAL), PIPE TEST TRIENNIALLY UST Monitor Method: SW TANK SW SUCTION PIPE W/DAILY RECONCILIATION OR WEEKLY GAUGING:
Monitor Code: 06
Delivery System: GRAVITY
Pipe Type: SINGLE WALL
Year Installed: 1983-01-01 00:00:00
Remove Close Date: 1998-10-20 00:00:00
Reg Status: REMOVED
Other Content Info: WASTE OIL
UST Contents: Not reported
Capacity Gallons: 550
Additional Id: LC-2
Tank Type: SINGLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T001
UST:
Activity: ACTIVE
and/or not onsite. 2715(f)
Violation Citation: Facility employee(s) are not trained, training records are incomplete, Violation: NO TRAINING/RECORD INCOMPLETE-NOT ONSITE
Violation Code: 6HV3193
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
waste as defined by law. CCR 66262.11 & 66260.200( c)
Violation Citation: Generator of a waste has not determined if that waste is a hazardous Violation: WASTE DETERMINATION NOT MADE
Violation Code: 6HV0304
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
262.34(e)&(f), &/or 25201(a) [>90 days for AHW waste]
Violation Citation: Accumulated waste too long (>180 or 270 days). 66262.34(d), CFR Violation: ACCUMULATED HW>180 OR >270 DAYS
Violation Code: 6HV0225
Inspection Date: 08/10/2010
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
waste regulations. CCR 66265.16(a)&(b)
Violation Citation: Personnel training is not adequate to ensure compliance with hazardous Violation: TRAINING PROGRAM NOT ADEQUATE
Violation Code: 6HV0402
Inspection Date: 06/13/2005
Update Date: 11/02/2012
Permit Number: 120813
Activity: ACTIVE
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 252
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Solid Waste Id No: Not reported
WID Id: Not reported
Region 2: Not reported
Effective Date: Not reported
Waste Discharge System No: Not reported
Order No: Not reported
Flag: active
Swat R: Not reported
Enf Type: Not reported
Owner: Not reported
Longitude: Not reported
Latitude: Not reported
Site Code: Not reported
Status Date: Not reported
Cleanup Status: COMPLETED - CASE CLOSED
Site/Facility Type: LUST CLEANUP SITE
Global ID: T0607399053
Envirostor Id: Not reported
Region: CORTESE
City,State,Zip: SANTEE, CA 920713005
Address: 9000 COTTONWOOD AV
Name: LAS COLINAS DETENTION FACILITY
CORTESE:
MONITORS: INTERSTITIAL.
UST Monitor Method: DW TANK DW SUCTION AND/ OR GRAVITY PIPING WITH INTERSTITIAL Monitor Code: 21
Delivery System: SUCTION
Pipe Type: DOUBLE WALL
Year Installed: 1998-01-01 00:00:00
Remove Close Date: Not reported
Reg Status: ACTIVE
Other Content Info: DIESEL
UST Contents: DIESEL
Capacity Gallons: 1000
Additional Id: NT2127 DIESEL; RT2713
Tank Type: DOUBLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
UST Name: UNDERGROUND TANK 120813 T003
TANK TEST ANNUAL (EXEMPT IF UST < 551 GAL), PIPE TEST TRIENNIALLY UST Monitor Method: SW TANK SW SUCTION PIPE W/DAILY RECONCILIATION OR WEEKLY GAUGING:
Monitor Code: 06
Delivery System: SUCTION
Pipe Type: SINGLE WALL
Year Installed: 1978-01-01 00:00:00
Remove Close Date: 1998-10-20 00:00:00
Reg Status: REMOVED
Other Content Info: DIESEL
UST Contents: DIESEL
Capacity Gallons: 1000
Additional Id: LC-1 (NT2127)
Tank Type: SINGLE WALL
Permit Number: 120813
Last Update: 2012-11-02 14:17:38
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 253
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Longitude: -116.973614
Latitude: 32.839649
Violations within 5 years: 0
Enforcement Actions within 5 years: 0
TTWQ: Not reported
Complexity: Not reported
Major/Minor: Not reported
Design Flow: Not reported
Expiration/Review Date: Not reported
Termination Date: 12/04/2015
Effective Date: 05/16/2012
Adoption Date: Not reported
NPDES Number: CAS000002
WDID: 9 37C363643
Order Number: 2009-0009-DWQ
Regulatory Measure Type: Storm water construction
Regulatory Measure Status: Terminated
Program: CONSTW
Region: 9
SIC/NAICS: Not reported
Place/Project Type: Construction
Agency Address: 5560 Overland Ave Suite 410, San Diego, CA 92123 Agency: County Of San Diego
City,State,Zip: SANTEE, CA 92071
Address: 9000 COTTONWOOD AVENUE
Name: WOMENS DETENTION FACILITY
CIWQS:
Y MapCoord: 1886180.637
X MapCoord: 6339211.047
Longitude: -116.9742539
Latitude: 32.8399908
Fire Agency: PADRE DAM MUNICIPAL WATER DISTRICT
Water Purveyor: PADRE DAM MUNICIPAL WATER DISTRICT
Watershed Basin Number: 907.12
Jurisdiction: SANTEE
Community: Santee
Census Tract: 166.15
Lead Agency Date: 06/03/1999
Lead Agency: DEH/SAM
Funding: F - LOP Federal Fund
SWRCB Global ID: T0607399053
Historical Name: COUNTY OF SD-LAS COLINAS DETEN
Case Type: LOP - Local Oversight Program
Parcel Number: 381-050-37-00
Opened Date: 05/10/1999
Record Status: Completed
Record ID: DEH1999-LSAM-H20813-001
City,State,Zip: SANTEE, CA 92071
Address: 9000 COTTONWOOD AVE
Name: LAS COLINAS DETENTION FACILITY
SAN DIEGO CO LOP:
File Name: Active Open
Waste Management Uit Name: Not reported
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 TC7493604.2s Page 254
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Affiliation Phone: ,
Affiliation Zip: Not reported
Affiliation Country: Not reported
Affiliation State: CA
Affiliation City: San Diego
Affiliation Address: P.O. Box 129261
Entity Title: Not reported
Entity Name: CAROL FENNER - SAN DIEGO COUNTY LOP
Affiliation Type Desc: Local Agency Caseworker
Affiliation:
CERS Description: Cleanup Program Site
CERS ID: T10000004142
Site ID: 681933
City,State,Zip: SANTEE, CA 92071
Address: 9000 COTTONWOOD AVENUE
Name: SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY
CERS Description: Leaking Underground Storage Tank Cleanup Site CERS ID: T0607399053
Site ID: 664607
City,State,Zip: SANTEE, CA 920713005
Address: 9000 COTTONWOOD AV
Name: LAS COLINAS DETENTION FACILITY
Affiliation Phone: ,
Affiliation Zip: Not reported
Affiliation Country: Not reported
Affiliation State: CA
Affiliation City: San Diego
Affiliation Address: P.O. Box 129261
Entity Title: Not reported
Entity Name: CAROL FENNER - SAN DIEGO COUNTY LOP
Affiliation Type Desc: Local Agency Caseworker
Affiliation:
CERS Description: Cleanup Program Site
CERS ID: T10000006155
Site ID: 681933
City,State,Zip: SANTEE, CA 92071
Address: 9000 COTTONWOOD AVENUE
Name: SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY
CERS:
SAN DIEGO COUNTY WOMEN’S DETENTION FACILITY (Continued) S106061773 Staff Initials: Not reported
Date Reported: Not reported
City,State,Zip: SANTEE, CA
Address: Not reported
Name: EDGEMORE HOSPITAL
NOTIFY 65:
2114 ft. Site 3 of 3 in cluster G
0.400 mi.
Relative:
Higher
Actual:
350 ft.
1/4-1/2 SANTEE, CA
SSE N/A
G26 EDGEMORE HOSPITAL Notify 65 S100178162
TC7493604.2s Page 255
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Status: Not reported
Global ID: Not reported
Incident Description: Not reported
Issue Date: Not reported
Discharge Date: Not reported
Facility Type: Not reported
Board File Number: Not reported
EDGEMORE HOSPITAL (Continued) S100178162
Local Case Number: H14318-002
File Location: Local Agency
Local Agency: Not reported
RB Case Number: 9UT3737
Case Worker: Not reported
Status Date: 05/09/2001
Status: Completed - Case Closed
Longitude: -116.9719531
Latitude: 32.8419479
Global Id: T0607302505
Geo Track: http://geotracker.waterboards.ca.gov/profile_report.asp?global_id=T0607302505 Case Type: LUST Cleanup Site
Lead Agency: SAN DIEGO COUNTY LOP
City,State,Zip: SANTEE, CA 920713037
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
LUST:
Date Began: 10/20/1998
Date: 5/9/2001
Facility Status: Closed Case
Facility Type: Soils Only
Funding: LOP - Federal Fund
Agency: DEH Site Assessment & Mitigation
Case Number: H14318-002
City,State,Zip: SANTEE, CA 920713037
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
Date Began: 4/23/1991
Date: 3/12/1992
Facility Status: Closed Case
Facility Type: Complaint
Funding: Non Billable
Agency: DEH Site Assessment & Mitigation
Case Number: H14318-001
City,State,Zip: SANTEE, CA 920713037
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
SAN DIEGO CO. SAM:
CERS
SAN DIEGO CO LOP
HIST CORTESE
2172 ft. Site 1 of 3 in cluster H HIST UST
0.411 mi. SWEEPS UST
Relative:
Higher
Actual:
350 ft.
1/4-1/2 SANTEE, CA 92071 CPS-SLIC
SSE 9065 EDGEMOOR DR LUST N/A
H27 EDGEMOOR GERIATRIC HOSPITAL SAN DIEGO CO. SAM U001572267 TC7493604.2s Page 256
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Global Id: T0607302505
Status Date: 10/20/1998
Status: Open - Case Begin Date
Global Id: T0607302505
LUST:
Action: Leak Discovery
Date: 10/20/1998
Action Type: Other
Global Id: T0607302505
Action: Leak Stopped
Date: 10/20/1998
Action Type: Other
Global Id: T0607302505
Action: Closure/No Further Action Letter
Date: 05/09/2001
Action Type: ENFORCEMENT
Global Id: T0607302505
Action: Leak Began
Date: 10/20/1998
Action Type: Other
Global Id: T0607302505
Action: Leak Reported
Date: 10/20/1998
Action Type: Other
Global Id: T0607302505
LUST:
Site History: Not reported
RWQCB Region: SAN DIEGO RWQCB (REGION 9)
Facility Project Subtype: Not reported
Military DOD Site: No
CA Enviroscreen 4 Score: 15-20%
CA Enviroscreen 3 Score: 41-45%
Disadvantaged Community: Not reported
Dwr Groundwater Subbasin Name: San Diego River Valley (9-015) CA Water Watershed Name: San Diego - Lower San Diego - Santee (907.12) No Further Action Date: 05/09/2001
Stop Description: CLOSE AND REMOVE TANK
Stop Method: Close and Remove Tank
Discharge Cause: Physc / Mech Damage
Discharge Source: Tank
How Discovered Description: Not reported
How Discovered: Not reported
Leak Reported Date: 10/20/1998
Begin Date: 10/20/1998
Quantity Released Gallons: Not reported
Cuf Case: NO
Coordinate Source: Google Geocode
EPA Region: 9
Potential Contaminants of Concern: Diesel
Potential Media Affect: Soil
EDGEMOOR GERIATRIC HOSPITAL (Continued) U001572267
TC7493604.2s Page 257
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Board Of Equalization: 44-022185
Number: Not reported
Comp Number: 14318
Status: Not reported
City: SANTEE
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
SWEEPS UST:
Click here to access the California GeoTracker records for this facility:
Site History: Not reported
RWQCB Region: SAN DIEGO RWQCB (REGION 9)
Facility Project Subtype: Not reported
Military DOD Site: No
CA Enviroscreen 4 Score: 15-20%
CA Enviroscreen 3 Score: 41-45%
Disadvantaged Community: Not reported
Dwr Groundwater Subbasin Name: San Diego River Valley (9-015) CA Water Watershed Name: San Diego - Lower San Diego - Santee (907.12) No Further Action Date: 03/12/1992
Stop Description: REMOVE CONTENTS
Stop Method: Remove Contents
Discharge Cause: Other
Discharge Source: Other
How Discovered Description: Not reported
How Discovered: Not reported
Leak Reported Date: 04/23/1991
Begin Date: 04/23/1991
Quantity Released Gallons: Not reported
Cuf Case: NO
Coordinate Source: Google Geocode
EPA Region: 9
Potential Contaminants of Concern: Not reported
Potential Media Affected: Under Investigation
File Location: Local Agency
RB Case Number: Not reported
Local Agency: SAN DIEGO COUNTY LOP
Case Worker: KH
Case Type: Cleanup Program Site
Longitude: -116.97027
Latitude: 32.840452
Lead Agency Case Number: H14318-001
Lead Agency: SAN DIEGO COUNTY LOP
Global Id: T0608198078
Status Date: 03/12/1992
Facility Status: Completed - Case Closed
Region: STATE
City,State,Zip: SANTEE, CA 920713037
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
CPS-SLIC:
Status Date: 05/09/2001
Status: Completed - Case Closed
EDGEMOOR GERIATRIC HOSPITAL (Continued) U001572267
TC7493604.2s Page 258
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Status: Active
City: SANTEE
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
Number Of Tanks: Not reported
Content: OTHER
STG: P
Tank Use: M.V. FUEL
Active Date: Not reported
Capacity: 5000
Tank Status: A
SWRCB Tank Id: 37-000-014318-000002
Owner Tank Id: Not reported
Created Date: 02-29-88
Action Date: 06-26-92
Referral Date: Not reported
Board Of Equalization: 44-022185
Number: 9
Comp Number: 14318
Status: Active
City: SANTEE
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
Number Of Tanks: 3
Content: OTHER
STG: P
Tank Use: M.V. FUEL
Active Date: Not reported
Capacity: 2000
Tank Status: A
SWRCB Tank Id: 37-000-014318-000001
Owner Tank Id: Not reported
Created Date: 02-29-88
Action Date: 06-26-92
Referral Date: Not reported
Board Of Equalization: 44-022185
Number: 9
Comp Number: 14318
Status: Active
City: SANTEE
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
Number Of Tanks: 1
Content: LEADED
STG: PRODUCT
Tank Use: M.V. FUEL
Active Date: Not reported
Capacity: 1000
Tank Status: Not reported
SWRCB Tank Id: 37-000-014318-000004
Owner Tank Id: Not reported
Created Date: Not reported
Action Date: Not reported
Referral Date: Not reported
EDGEMOOR GERIATRIC HOSPITAL (Continued) U001572267
TC7493604.2s Page 259
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Type of Fuel: Not reported
Tank Used for: PRODUCT
Tank Capacity: 00001000
Year Installed: Not reported
Container Num: GS 030
Tank Num: 003
Leak Detection: None
Container Construction Thickness: Not reported
Type of Fuel: DIESEL
Tank Used for: PRODUCT
Tank Capacity: 00005000
Year Installed: Not reported
Container Num: GSO42
Tank Num: 002
Leak Detection: None
Container Construction Thickness: Not reported
Type of Fuel: Not reported
Tank Used for: PRODUCT
Tank Capacity: 00001800
Year Installed: Not reported
Container Num: GS 032
Tank Num: 001
Total Tanks: 0004
Owner City,St,Zip: SAN DIEGO, CA 92123
Owner Address: 5555 OVERLAND AVE
Owner Name: COUNTY OF SAN DIEGO
Telephone: 6195655274
Contact Name: HILDO HERNANDEZ (565-5274)
Other Type: HOSPITAL/HEATING
Facility Type: Other
Facility ID: 00000044190
Region: STATE
URL: Not reported
File Number: Not reported
City,State,Zip: SANTEE, CA 92071
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
HIST UST:
Number Of Tanks: Not reported
Content: OTHER
STG: P
Tank Use: M.V. FUEL
Active Date: Not reported
Capacity: 1000
Tank Status: A
SWRCB Tank Id: 37-000-014318-000003
Owner Tank Id: Not reported
Created Date: 02-29-88
Action Date: 06-26-92
Referral Date: Not reported
Board Of Equalization: 44-022185
Number: 9
Comp Number: 14318
EDGEMOOR GERIATRIC HOSPITAL (Continued) U001572267
TC7493604.2s Page 260
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Affiliation Type Desc: Local Agency Caseworker
Affiliation:
CERS Description: Cleanup Program Site
CERS ID: T0608198078
Site ID: 651177
City,State,Zip: SANTEE, CA 920713037
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
CERS:
Y MapCoord: Not reported
X MapCoord: Not reported
Longitude: Not reported
Latitude: Not reported
Fire Agency: Not reported
Water Purveyor: Not reported
Watershed Basin Number: Not reported
Jurisdiction: Not reported
Community: Not reported
Census Tract: Not reported
Lead Agency Date: 10/20/1998
Lead Agency: DEH/SAM
Funding: F - LOP Federal Fund
SWRCB Global ID: T0607302505
Historical Name: EDGEMOOR
Case Type: LOP - Local Oversight Program
Parcel Number: 384-111-07-00
Opened Date: 10/20/1998
Record Status: Completed
Record ID: DEH1998-LSAM-H14318-002
City,State,Zip: SANTEE, CA 92071
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
SAN DIEGO CO LOP:
Reg Id: 9UT3737
Reg By: LTNKA
Facility County Code: 37
Region: CORTESE
City,State,Zip: SANTEE, CA 92071
edr_fadd1: 9065 EDGEMOOR
edr_fname: EDGEMOOR
HIST CORTESE:
Leak Detection: None
Container Construction Thickness: Not reported
Type of Fuel: Not reported
Tank Used for: PRODUCT
Tank Capacity: 00001800
Year Installed: Not reported
Container Num: GS 031
Tank Num: 004
Leak Detection: None
Container Construction Thickness: Not reported
EDGEMOOR GERIATRIC HOSPITAL (Continued) U001572267
TC7493604.2s Page 261
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Affiliation Phone: ,
Affiliation Zip: Not reported
Affiliation Country: Not reported
Affiliation State: CA
Affiliation City: San Diego
Affiliation Address: P.O. Box 129261
Entity Title: Not reported
Entity Name: KEVIN HEATON - SAN DIEGO COUNTY LOP
Affiliation Type Desc: Local Agency Caseworker
Affiliation:
CERS Description: Leaking Underground Storage Tank Cleanup Site CERS ID: T0607302505
Site ID: 651177
City,State,Zip: SANTEE, CA 920713037
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
Affiliation Phone: ,
Affiliation Zip: Not reported
Affiliation Country: Not reported
Affiliation State: CA
Affiliation City: San Diego
Affiliation Address: P.O. Box 129261
Entity Title: Not reported
Entity Name: KEVIN HEATON - SAN DIEGO COUNTY LOP
EDGEMOOR GERIATRIC HOSPITAL (Continued) U001572267
Own Or Operate UST: Not reported
Handle Regulated Hazmat: Not reported
UST Owner: Not reported
Facility Mailing Zip: 92116-
Facility Mailing State: CA
Facility Mailing City: SAN DIEGO
Facility Mailing Address: 2840 ADAMS AV 103
Facility Owner: HEARTLAND AND ADHC
Date Last Updated: 11/02/2012
Permit Expiration: 04/12/1999
Permit Status: INAC
Facility Telephone: 619-283-5731
Last HMMD Inspection: 04/12/1999
APN: 384-111-07-00
EPA Id Number: Not reported
Business Type: 6HK10
Permit Number: 153095
City,State,Zip: SANTEE, CA 92071
Address: 9065 EDGEMOOR DR
Name: HEARTLAND- ADHC
HMMD SAN DIEGO:
No Details: No Details
LUST:
2172 ft. Site 2 of 3 in cluster H
0.411 mi.
Relative:
Higher
Actual:
350 ft.
1/4-1/2 SANTEE, CA 92071
SSE 9065 EDGEMOOR DR San Diego Co. HMMD N/A
H28 HEARTLAND- ADHC LUST S105035138
TC7493604.2s Page 262
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Generate Medical Waste: Not reported
Treat Haz Waste: Not reported
Generate Haz Waste: Not reported
Subject To APSA: Not reported
HEARTLAND- ADHC (Continued) S105035138
Contact Name: ANDRE PHILLIPS/SAFETY COORD
Owner Fax: Not reported
Owner Phone: Not reported
Owner City,State,Zip: SAN DIEGO, CA 92123
Owner Address 2: Not reported
Owner Address: 5555 OVERLAND AVE BUILDING 2 RM 360
Owner Name: COUNTY OF SAN DIEGO
Mailing City,State,Zip: SAN DIEGO, CA 92123
Mailing Address 2: Not reported
Mailing Address: 5555 OVERLAND AVE BUILDING 2 RM 360
Mailing Name: Not reported
Last Act Date: Not reported
Create Date: 05/10/1990
Inactive Date: 06/30/2003
EPA ID: CAL000028400
City,State,Zip: SANTEE, CA 92071
Address 2: Not reported
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
HWTS:
File Name: Active Open
Waste Management Uit Name: Not reported
Solid Waste Id No: Not reported
WID Id: Not reported
Region 2: Not reported
Effective Date: Not reported
Waste Discharge System No: Not reported
Order No: Not reported
Flag: active
Swat R: Not reported
Enf Type: Not reported
Owner: Not reported
Longitude: Not reported
Latitude: Not reported
Site Code: Not reported
Status Date: Not reported
Cleanup Status: COMPLETED - CASE CLOSED
Site/Facility Type: LUST CLEANUP SITE
Global ID: T0607302505
Envirostor Id: Not reported
Region: CORTESE
City,State,Zip: SANTEE, CA 920713037
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
CORTESE:
2172 ft. Site 3 of 3 in cluster H
0.411 mi.
Relative:
Higher
Actual:
350 ft.
1/4-1/2 SANTEE, CA 92071 HAZNET
SSE 9065 EDGEMOOR DR HWTS N/A
H29 EDGEMOOR GERIATRIC HOSPITAL Cortese S113032110
TC7493604.2s Page 263
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Tons: 3.3712
Disposal Method: D80 - Disposal, Land Fill
CA Waste Code: 151 - Asbestos containing waste
TSD EPA ID: AZC950823111
Gepaid: CAL000028400
Year: 2002
Tons: 7.5852
Disposal Method: D80 - Disposal, Land Fill
CA Waste Code: 151 - Asbestos containing waste
TSD EPA ID: AZC950823111
Gepaid: CAL000028400
Year: 2003
Tons: 16.94028
Disposal Method: D80 - Disposal, Land Fill
CA Waste Code: 151 - Asbestos containing waste
TSD EPA ID: CAD009007626
Gepaid: CAL000028400
Year: 2003
Mailing Address: 5555 Overland Ave Building 2 Rm 360
Mailing Name: Not reported
Telephone: 8586942478
Contact: Andre Phillips/safety coord
City,State,Zip: SANTEE, CA 920713037
Address 2: Not reported
Address: 9065 EDGEMOOR DR
Name: EDGEMOOR GERIATRIC HOSPITAL
HAZNET:
Facility Zip: 920713037
Facility State: CA
Facility County: Not reported
Facility City: SANTEE
Facility Address 2: Not reported
Facility Address: 9065 EDGEMOOR DR
Facility Name: EDGEMOOR GERIATRIC HOSPITAL
Inactive Date: 2003-06-30 00:00:00
Issued EPA ID Date: 1990-05-10 00:00:00
NAICS Description: Other General Government Support
NAICS Code: 92119
Create Date: 2002-11-21 09:39:48.873
EPA ID: CAL000028400
NAICS:
Longitude: -116.970124
Latitude: 32.840131
Category: STATE
Facility Type: PERMANENT
Facility Status: Inactive
Contact Fax: Not reported
Contact Phone: Not reported
City,State,Zip: SAN DIEGO, CA 92123
Contact Address 2: Not reported
Contact Address: 5555 OVERLAND AVE BUILDING 2 RM 360
EDGEMOOR GERIATRIC HOSPITAL (Continued) S113032110
TC7493604.2s Page 264
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Additional Code 5: Not reported
Additional Code 4: Not reported
Additional Code 3: Not reported
Additional Code 2: Not reported
Additional Code 1: Not reported
Quantity Unit: Y
Waste Quantity: 0.6
Quantity Tons: 0.50568
Meth Code: D80 - Disposal, Land Fill
RCRA Code: Not reported
Waste Code Description: 151 - Asbestos-containing waste TSDF Alt Name: Not reported
TSDF Alt EPA ID: CAD009007626
Trans Name: Not reported
TSDF EPA ID: CAD009007626
Trans 2 Name: Not reported
Trans 2 EPA ID: CAR000017657
Trans Name: Not reported
Trans EPA ID: CAL000252045
Manifest ID: 22086085
Receipt Date: 20030915
Creation Date: 8/2/2004 9:36:58
Shipment Date: 20030911
Gen EPA ID: CAL000028400
Year: 2003
Additional Info:
Tons: 0.0208
Disposal Method: 14 -
CA Waste Code: 343 - Unspecified organic liquid mixture TSD EPA ID: CAT080010101
Gepaid: CAL000028400
Year: 1989
Tons: 0.0208
Disposal Method: H01 - Transfer Station
CA Waste Code: 214 - Unspecified solvent mixture
TSD EPA ID: CAT080010101
Gepaid: CAL000028400
Year: 1990
Tons: 16.856
Disposal Method: D80 - Disposal, Land Fill
CA Waste Code: 151 - Asbestos containing waste
TSD EPA ID: CAL000027741
Gepaid: CAL000028400
Year: 1995
Tons: 2.502
Disposal Method: R01 - Recycler
CA Waste Code: 223 - Unspecified oil-containing waste
TSD EPA ID: CAT080013352
Gepaid: CAL000028400
Year: 1998
EDGEMOOR GERIATRIC HOSPITAL (Continued) S113032110
TC7493604.2s Page 265
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
TSDF EPA ID: AZC950823111
Trans 2 Name: Not reported
Trans 2 EPA ID: CAR000049064
Trans Name: Not reported
Trans EPA ID: CAR000047993
Manifest ID: 22251668
Receipt Date: Not reported
Creation Date: 5/28/2003 18:32:22
Shipment Date: 20030313
Additional Code 5: Not reported
Additional Code 4: Not reported
Additional Code 3: Not reported
Additional Code 2: Not reported
Additional Code 1: Not reported
Quantity Unit: Y
Waste Quantity: 18
Quantity Tons: 15.1704
Meth Code: D80 - Disposal, Land Fill
RCRA Code: Not reported
Waste Code Description: 151 - Asbestos-containing waste TSDF Alt Name: Not reported
TSDF Alt EPA ID: CAD009007626
Trans Name: Not reported
TSDF EPA ID: CAD009007626
Trans 2 Name: Not reported
Trans 2 EPA ID: CAR000049064
Trans Name: Not reported
Trans EPA ID: CAR000047993
Manifest ID: 22251677
Receipt Date: 20030321
Creation Date: 3/16/2007 18:30:50
Shipment Date: 20030317
Additional Code 5: Not reported
Additional Code 4: Not reported
Additional Code 3: Not reported
Additional Code 2: Not reported
Additional Code 1: Not reported
Quantity Unit: Y
Waste Quantity: 1.5
Quantity Tons: 1.2642
Meth Code: D80 - Disposal, Land Fill
RCRA Code: Not reported
Waste Code Description: 151 - Asbestos-containing waste TSDF Alt Name: Not reported
TSDF Alt EPA ID: CAD009007626
Trans Name: Not reported
TSDF EPA ID: CAD009007626
Trans 2 Name: Not reported
Trans 2 EPA ID: CAR000017657
Trans Name: Not reported
Trans EPA ID: CAL000252045
Manifest ID: 22086063
Receipt Date: 20030801
Creation Date: 7/26/2004 18:30:41
Shipment Date: 20030722
EDGEMOOR GERIATRIC HOSPITAL (Continued) S113032110
TC7493604.2s Page 266
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
TSDF EPA ID: CAT080013352
Trans 2 Name: Not reported
Trans 2 EPA ID: Not reported
Trans Name: Not reported
Trans EPA ID: CA0000039461
Manifest ID: 98087719
Receipt Date: 19981104
Creation Date: 1/13/1999 0:00:00
Shipment Date: 19981102
Gen EPA ID: CAL000028400
Year: 1998
Additional Info:
Additional Code 5: Not reported
Additional Code 4: Not reported
Additional Code 3: Not reported
Additional Code 2: Not reported
Additional Code 1: Not reported
Quantity Unit: Y
Waste Quantity: 4
Quantity Tons: 3.3712
Meth Code: D80 - Disposal, Land Fill
RCRA Code: Not reported
Waste Code Description: 151 - Asbestos-containing waste TSDF Alt Name: Not reported
TSDF Alt EPA ID: Not reported
Trans Name: Not reported
TSDF EPA ID: AZC950823111
Trans 2 Name: Not reported
Trans 2 EPA ID: CAR000049064
Trans Name: Not reported
Trans EPA ID: CAR000047993
Manifest ID: 22251611
Receipt Date: 20021129
Creation Date: 3/15/2003 18:31:28
Shipment Date: 20021122
Gen EPA ID: CAL000028400
Year: 2002
Additional Info:
Additional Code 5: Not reported
Additional Code 4: Not reported
Additional Code 3: Not reported
Additional Code 2: Not reported
Additional Code 1: Not reported
Quantity Unit: Y
Waste Quantity: 9
Quantity Tons: 7.5852
Meth Code: D80 - Disposal, Land Fill
RCRA Code: Not reported
Waste Code Description: 151 - Asbestos-containing waste TSDF Alt Name: Not reported
TSDF Alt EPA ID: Not reported
Trans Name: Not reported
EDGEMOOR GERIATRIC HOSPITAL (Continued) S113032110
TC7493604.2s Page 267
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
RCRA Code: Not reported
Waste Code Description: 151 - Asbestos-containing waste TSDF Alt Name: Not reported
TSDF Alt EPA ID: Not reported
Trans Name: Not reported
TSDF EPA ID: CAL000027741
Trans 2 Name: Not reported
Trans 2 EPA ID: CAD983668583
Trans Name: Not reported
Trans EPA ID: CAL922304939
Manifest ID: 95152659
Receipt Date: 19951201
Creation Date: 7/26/1996 0:00:00
Shipment Date: 19951127
Gen EPA ID: CAL000028400
Year: 1995
Additional Info:
Additional Code 5: Not reported
Additional Code 4: Not reported
Additional Code 3: Not reported
Additional Code 2: Not reported
Additional Code 1: Not reported
Quantity Unit: G
Waste Quantity: 400
Quantity Tons: 1.668
Meth Code: R01 - Recycler
RCRA Code: Not reported
Waste Code Description: 223 - Unspecified oil-containing waste TSDF Alt Name: Not reported
TSDF Alt EPA ID: CAT080013352
Trans Name: Not reported
TSDF EPA ID: CAT080013352
Trans 2 Name: Not reported
Trans 2 EPA ID: Not reported
Trans Name: Not reported
Trans EPA ID: CA0000039461
Manifest ID: 98087712
Receipt Date: 19981021
Creation Date: 12/17/1998 0:00:00
Shipment Date: 19981019
Additional Code 5: Not reported
Additional Code 4: Not reported
Additional Code 3: Not reported
Additional Code 2: Not reported
Additional Code 1: Not reported
Quantity Unit: G
Waste Quantity: 200
Quantity Tons: 0.834
Meth Code: R01 - Recycler
RCRA Code: Not reported
Waste Code Description: 223 - Unspecified oil-containing waste TSDF Alt Name: Not reported
TSDF Alt EPA ID: CAT080013352
Trans Name: Not reported
EDGEMOOR GERIATRIC HOSPITAL (Continued) S113032110
TC7493604.2s Page 268
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Additional Code 5: Not reported
Additional Code 4: Not reported
Additional Code 3: Not reported
Additional Code 2: Not reported
Additional Code 1: Not reported
Quantity Unit: Y
Waste Quantity: 20
Quantity Tons: 16.856
Meth Code: D80 - Disposal, Land Fill
EDGEMOOR GERIATRIC HOSPITAL (Continued) S113032110
RWQCB Region: SAN DIEGO RWQCB (REGION 9)
Facility Project Subtype: Not reported
Military DOD Site: No
CA Enviroscreen 4 Score: 10-15%
CA Enviroscreen 3 Score: 6-10%
Disadvantaged Community: Not reported
Dwr Groundwater Subbasin Name: San Diego River Valley (9-015) CA Water Watershed Name: San Diego - Lower San Diego - Santee (907.12) No Further Action Date: 01/05/2017
Stop Description: Not reported
Stop Method: Not reported
Discharge Cause: Not reported
Discharge Source: Not reported
How Discovered Description: Not reported
How Discovered: Not reported
Leak Reported Date: Not reported
Begin Date: 01/19/2016
Quantity Released Gallons: Not reported
Cuf Case: NO
Coordinate Source: Google Map Move
EPA Region: 9
(TPH)
Trichloroethylene (TCE), Vinyl chloride, Total Petroleum Hydrocarbons Potential Contaminants of Concern: Other Chlorinated Hydrocarbons, Tetrachloroethylene (PCE), Potential Media Affected: Aquifer used for drinking water supply, Soil, Soil Vapor File Location: Not reported
RB Case Number: Not reported
Local Agency: SAN DIEGO COUNTY LOP
Case Worker: TS
Case Type: Cleanup Program Site
Longitude: -116.97180594841
Latitude: 32.856416474261
Lead Agency Case Number: DEH2016-LSAM-000352
Lead Agency: SAN DIEGO COUNTY LOP
Global Id: T10000008333
Status Date: 01/05/2017
Facility Status: Completed - Case Closed
Region: STATE
City,State,Zip: SANTEE, CA 92071
Address: 9866 NORTH MAGNOLIA AVENUE
Name: DAISY CLEANER - SANTANA VILLAGE SHOPPING CENTER
CPS-SLIC:
2509 ft.
0.475 mi.
Relative:
Higher
Actual:
371 ft.
1/4-1/2 SANTEE, CA 92071
NNE 9866 NORTH MAGNOLIA AVENUE CERS N/A
30 DAISY CLEANER - SANTANA VILLAGE SHOPPING CENTER S118504762 CPS-SLIC TC7493604.2s Page 269
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Click here to access the California GeoTracker records for this facility:
DEH2016-LMWP-002534.
groundwater monitoring wells were destroyed under DEH Permit number further site investigation. DEH approves case closure. The two site occupants posed by vapor intrusion. The consultant recommends no of 5 g/l. In addition, there are no significant risks to building groundwater is lower than the Maximum Contaminant Level (MCL) for PCE concern nor a health risk. Also, the detected PCE concentration in petroleum hydrocarbons at the site represent neither an environmental two groundwater samples. The consultant concludes that the detected a dissolved PCE concentration of 2.1 g/l were reported in one of the dissolved TPH-d concentration of 100 micrograms per liter ( g/l) and sample, but VOCs were not detected in any of the soil samples. A mg/kg) and TPH in the oil range (34 mg/kg) were detected in one soil extent of contamination. Relatively low concentrations of TPH-d (9.7 feet bgs behind the building to further evaluate the nature and 2016, two borings/monitoring wells were installed to a depth of 21 uses, including municipal use. Between June 29, 2016 and July 6, site is located in a groundwater basin with designated beneficial million risk considered to be of potential human health concern. The cancer risks from soil vapors at the site are below the one-in-one the screening level. DEH staff confirmed that the calculated excess in the vapor sample collected beneath the inside floor did not exceed commercial/industrial land use sites. The PCE concentration detected exceeded the California Human Health Screening Levels for TCE, and vinyl chloride detected in the outside boring vapor samples and asphalt. The consultant stated that the concentrations of PCE, the outdoor probes. The rear of the building is covered by concrete
0.053 mg/m3, respectively, were also detected in vapor samples from concentrations of 0.82 to 2.5 mg/m3 and not detected (<0.26 mg/m3) to
0.14 mg/m3 and 12.0 mg/m3. Trichloroethene (TCE) and vinyl chloride samples from the two outdoor vapor probes had PCE concentrations of a concentration of 0.044 milligrams per cubic meter (mg/m3). Vapor in one of the two samples collected beneath the dry cleaner floor at from a depth of 5 feet bgs from four vapor probes. PCE was detected in the B-4 soil sample. Four soil vapor samples were also collected (TPH-d) concentration of 1,100 milligrams per kilogram was reported any of the soil samples. A total petroleum hydrocarbons as diesel located outside the rear of the building. VOCs were not detected in building beneath the floor, and two borings (B-3 and B-4) were borings. Two of the borings (B-1 and B-2) were advanced inside of the collected at a depth of 5 feet below ground surface (bgs) from four vapor investigation was conducted at the site. Soil samples were located in front of the dry cleaners. In May 2015, a soil and soil borings or in a grab groundwater sample collected from a boring (VOCs) were detected in any of the soil samples collected from five releases had occurred at the site. No volatile organic compounds and adjacent to the dry cleaners to investigate whether solvent DF-2000. In 2003, two subsurface investigations were conducted within the machine was replaced by one that utilizes the hydrocarbon solvent tetrachloroethene (PCE) as a dry cleaning solvent until 2008, when reportedly operated at the site. The Daisy Cleaner used Shopping Center since 1992. Prior to 1992, a different dry cleaner Site History: The Daisy Cleaner has occupied a tenant space at the Santana Village DAISY CLEANER - SANTANA VILLAGE SHOPPING CENTER (Continued) S118504762 TC7493604.2s Page 270
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Affiliation Phone: ,
Affiliation Zip: Not reported
Affiliation Country: Not reported
Affiliation State: CA
Affiliation City: SAN DIEGO
Affiliation Address: P.O. Box 129261
Entity Title: Not reported
Entity Name: TERESA SHERMAN - SAN DIEGO COUNTY LOP
Affiliation Type Desc: Local Agency Caseworker
Affiliation:
CERS Description: Cleanup Program Site
CERS ID: T10000008333
Site ID: 649035
City,State,Zip: SANTEE, CA 92071
Address: 9866 NORTH MAGNOLIA AVENUE
Name: DAISY CLEANER - SANTANA VILLAGE SHOPPING CENTER
CERS:
DAISY CLEANER - SANTANA VILLAGE SHOPPING CENTER (Continued) S118504762 Alias Type: Project Code (Site Code)
Alias Name: 404785
Potential Description: NONE SPECIFIED
Confirmed COC: NONE SPECIFIED
Potential COC: NONE SPECIFIED
Past Use: NONE SPECIFIED
APN: NONE SPECIFIED
Longitude: -116.9710
Latitude: 32.85733
Funding: School District
Site Mgmt Req: NONE SPECIFIED
Restricted Use: NO
Special Program: Not reported
Senate: 40
Assembly: 75
Division Branch: Southern California Schools & Brownfields Outreach Supervisor: Shahir Haddad
Program Manager: Aslam Shareef
Lead Agency: SMBRP
Regulatory Agencies: SMBRP
NPL: NO
Acres: 1
Site Type Detailed: School
Site Type: School Investigation
Site Code: 404785
Status Date: 09/23/2008
Status: Inactive - Withdrawn
Facility ID: 60000859
City,State,Zip: SANTEE, CA 92071
Address: 9915 MAGNOLIA AVENUE
Name: SANTANA HIGH SCHOOL
ENVIROSTOR:
3009 ft.
0.570 mi.
Relative:
Higher
Actual:
383 ft.
1/2-1 SANTEE, CA 92071 CERS
NNE 9915 MAGNOLIA AVENUE SCH N/A
31 SANTANA HIGH SCHOOL ENVIROSTOR S103677965
TC7493604.2s Page 271
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Confirmed COC: NONE SPECIFIED
Potential COC: NONE SPECIFIED
Past Use: NONE SPECIFIED
APN: NONE SPECIFIED
Longitude: -116.9710
Latitude: 32.85733
Funding: School District
Restricted Use: NO
Status Date: 09/23/2008
Status: Inactive - Withdrawn
Special Program Status: Not reported
Senate: 40
Assembly: 75
Site Code: 404785
Division Branch: Southern California Schools & Brownfields Outreach Supervisor: Shahir Haddad
Project Manager: Aslam Shareef
Lead Agency Description: DTSC - Site Cleanup Program
Lead Agency: SMBRP
Cleanup Oversight Agencies: SMBRP
National Priorities List: NO
Acres: 1
Site Mgmt. Req.: NONE SPECIFIED
Site Type Detail: School
Site Type: School Investigation
Facility ID: 60000859
City,State,Zip: SANTEE, CA 92071
Address: 9915 MAGNOLIA AVENUE
Name: SANTANA HIGH SCHOOL
SCH:
Schedule Revised Date: Not reported
Schedule Due Date: Not reported
Schedule Document Type: Not reported
Schedule Sub Area Name: Not reported
Schedule Area Name: Not reported
Future Due Date: Not reported
Future Document Type: Not reported
Future Sub Area Name: Not reported
Future Area Name: Not reported
Comments: Not reported
Completed Date: 05/19/2008
Completed Document Type: Phase 1
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Not reported
Completed Date: 09/23/2008
Completed Document Type: Cost Recovery Closeout Memo
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Completed Info:
Alias Type: Envirostor ID Number
Alias Name: 60000859
SANTANA HIGH SCHOOL (Continued) S103677965
TC7493604.2s Page 272
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Affiliation Phone: ,
Affiliation Zip: Not reported
Affiliation Country: Not reported
Affiliation State: Not reported
Affiliation City: Not reported
Affiliation Address: Not reported
Entity Title: Not reported
Entity Name: Shahir Haddad
Affiliation Type Desc: Supervisor
Affiliation Phone: ,
Affiliation Zip: Not reported
Affiliation Country: Not reported
Affiliation State: Not reported
Affiliation City: Not reported
Affiliation Address: Not reported
Entity Title: Not reported
Entity Name: Aslam Shareef
Affiliation Type Desc: Lead Project Manager
Affiliation:
CERS Description: School Investigation
CERS ID: 60000859
Site ID: 610016
City,State,Zip: SANTEE, CA 92071
Address: 9915 MAGNOLIA AVENUE
Name: SANTANA HIGH SCHOOL
CERS:
Schedule Revised Date: Not reported
Schedule Due Date: Not reported
Schedule Document Type: Not reported
Schedule Sub Area Name: Not reported
Schedule Area Name: Not reported
Future Due Date: Not reported
Future Document Type: Not reported
Future Sub Area Name: Not reported
Future Area Name: Not reported
Comments: Not reported
Completed Date: 05/19/2008
Completed Document Type: Phase 1
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Not reported
Completed Date: 09/23/2008
Completed Document Type: Cost Recovery Closeout Memo
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Completed Info:
Alias Type: Envirostor ID Number
Alias Name: 60000859
Alias Type: Project Code (Site Code)
Alias Name: 404785
Potential Description: NONE SPECIFIED
SANTANA HIGH SCHOOL (Continued) S103677965
TC7493604.2s Page 273
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Activity Comments: Not reported
Removal Action Certification: Not reported
Action Included Fencing: Not reported
Well Decommissioned: Not reported
Action Included Capping: Not reported
Liquids Treated (Gals): 0
Liquids Removed (Gals): 0
Definition of Status: CERTIFIED
Activity Status: CERT
Request to Delete Activity: Not reported
Estimated Size: Not reported
Est Person-Yrs to complete: 0
Comments Date: 11081995
Revised Due Date: Not reported
AWP Completion Date: Not reported
Proposed Budget: 0
AWP Code: Not reported
Activity Name: DISCOVERY
Activity: DISC
Facility ID: 37750003
State Senate District Code: 36
State Assembly District Code: 77
Lat/Long Description: Not reported
Lat/long Method: Not reported
Lat/Long (dms): 0 0 0 / 0 0 0
Lat/Long Direction: Not reported
Region Water Control Board Name: SAN DIEGO
Region Water Control Board: SD
Supervisor Responsible for Site: Not reported
Staff Member Responsible for Site: JCULLY
Groundwater Contamination: Not reported
Date Site Hazard Ranked: Not reported
Hazardous Ranking Score: Not reported
Cortese: Not reported
Access: Not reported
SIC Name: AUTO REPAIR, SERVICES & PARKING
SIC Code: 75
NPL: Not Listed
Lead Agency: DEPT OF TOXIC SUBSTANCES CONTROL
Status Name: CERTIFIED
Status: CERTIFIED AS HAVING BEEN REMEDIED SATISFACTORILY UNDER DTSC OVERSIGHT State Senate District: 07302003
File Name: Not reported
Branch Name: SO CAL - CYPRESS
Branch: SB
Type: RESPONSIBLE PARTY
Facility Type: RP
Facility ID: 37750003
Region: CYPRESS
City: SANTEE
Address: 10438 MISSION GORGE ROAD
Name: DAVE’S AUTO SERVICE
Calsite:
3486 ft. Site 1 of 2 in cluster I
0.660 mi.
Relative:
Higher
Actual:
363 ft.
1/2-1 SANTEE, CA 92071
SSE 10438 MISSION GORGE ROAD N/A
I32 DAVE’S AUTO SERVICE HIST Cal-Sites S102860941
TC7493604.2s Page 274
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Proposed Budget: 0
AWP Code: ISED
Activity Name: I/SE, IORSE, FFA, FFSRA, VCA, EA
Activity: ORDER
Facility ID: 37750003
Unknown Type: 0
For Residential Reuse: 0
For Industrial Reuse: 0
For Commercial Reuse: 0
Activity Comments: Not reported
Removal Action Certification: Not reported
Action Included Fencing: Not reported
Well Decommissioned: Not reported
Action Included Capping: Not reported
Liquids Treated (Gals): 0
Liquids Removed (Gals): 0
Definition of Status: CERTIFIED
Activity Status: CERT
Request to Delete Activity: Not reported
Estimated Size: Not reported
Est Person-Yrs to complete: 0
Comments Date: 08021999
Revised Due Date: Not reported
AWP Completion Date: Not reported
Proposed Budget: 0
AWP Code: PASI
Activity Name: PRELIMINARY ENDANGERMENT ASSESSMENT
Activity: PEA
Facility ID: 37750003
Unknown Type: 0
For Residential Reuse: 0
For Industrial Reuse: 0
For Commercial Reuse: 0
Activity Comments: Not reported
Removal Action Certification: Not reported
Action Included Fencing: Not reported
Well Decommissioned: Not reported
Action Included Capping: Not reported
Liquids Treated (Gals): 0
Liquids Removed (Gals): 0
Definition of Status: CERTIFIED
Activity Status: CERT
Request to Delete Activity: Not reported
Estimated Size: Not reported
Est Person-Yrs to complete: 0
Comments Date: 12201995
Revised Due Date: Not reported
AWP Completion Date: Not reported
Proposed Budget: 0
AWP Code: Not reported
Activity Name: SITE SCREENING
Activity: SS
Facility ID: 37750003
Unknown Type: 0
For Residential Reuse: 0
For Industrial Reuse: 0
For Commercial Reuse: 0
DAVE’S AUTO SERVICE (Continued) S102860941
TC7493604.2s Page 275
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Liquids Removed (Gals): 172
Definition of Status: CERTIFIED
Activity Status: CERT
Request to Delete Activity: Not reported
Estimated Size: Not reported
Est Person-Yrs to complete: 0
Comments Date: 06272003
Revised Due Date: Not reported
AWP Completion Date: Not reported
Proposed Budget: 0
AWP Code: Not reported
Activity Name: REMOVAL ACTION
Activity: RA
Facility ID: 37750003
Unknown Type: 0
For Residential Reuse: 0
For Industrial Reuse: 0
For Commercial Reuse: 0
Activity Comments: Not reported
Removal Action Certification: Not reported
Action Included Fencing: Not reported
Well Decommissioned: Not reported
Action Included Capping: Not reported
Liquids Treated (Gals): 0
Liquids Removed (Gals): 0
Definition of Status: CERTIFIED
Activity Status: CERT
Request to Delete Activity: Not reported
Estimated Size: Not reported
Est Person-Yrs to complete: 0
Comments Date: 04102003
Revised Due Date: Not reported
AWP Completion Date: Not reported
Proposed Budget: 0
AWP Code: Not reported
Activity Name: REMOVAL ACTION WORKPLAN
Activity: RAW
Facility ID: 37750003
Unknown Type: 0
For Residential Reuse: 0
For Industrial Reuse: 0
For Commercial Reuse: 0
Activity Comments: Not reported
Removal Action Certification: Not reported
Action Included Fencing: Not reported
Well Decommissioned: Not reported
Action Included Capping: Not reported
Liquids Treated (Gals): 0
Liquids Removed (Gals): 0
Definition of Status: CERTIFIED
Activity Status: CERT
Request to Delete Activity: Not reported
Estimated Size: Not reported
Est Person-Yrs to complete: 0
Comments Date: 12222000
Revised Due Date: Not reported
AWP Completion Date: Not reported
DAVE’S AUTO SERVICE (Continued) S102860941
TC7493604.2s Page 276
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
For Residential Reuse: 0
For Industrial Reuse: 0
For Commercial Reuse: 0
Activity Comments: Not reported
Removal Action Certification: Not reported
Action Included Fencing: Not reported
Well Decommissioned: Not reported
Action Included Capping: Not reported
Liquids Treated (Gals): 0
Liquids Removed (Gals): 0
Definition of Status: CERTIFIED
Activity Status: CERT
Request to Delete Activity: Not reported
Estimated Size: Not reported
Est Person-Yrs to complete: 0
Comments Date: 11152002
Revised Due Date: Not reported
AWP Completion Date: Not reported
Proposed Budget: 0
AWP Code: PEAE
Activity Name: PRELIMINARY ENDANGERMENT ASSESSMENT
Activity: PEA
Facility ID: 37750003
Unknown Type: 0
For Residential Reuse: 0
For Industrial Reuse: 0
For Commercial Reuse: 0
Activity Comments: Not reported
Removal Action Certification: Not reported
Action Included Fencing: Not reported
Well Decommissioned: Not reported
Action Included Capping: Not reported
Liquids Treated (Gals): 0
Liquids Removed (Gals): 0
Definition of Status: CERTIFIED
Activity Status: CERT
Request to Delete Activity: Not reported
Estimated Size: Not reported
Est Person-Yrs to complete: 0
Comments Date: 07302003
Revised Due Date: Not reported
AWP Completion Date: Not reported
Proposed Budget: 0
AWP Code: Not reported
Activity Name: CERTIFICATION
Activity: CERT
Facility ID: 37750003
Unknown Type: 0
For Residential Reuse: 1
For Industrial Reuse: 0
For Commercial Reuse: 0
Activity Comments: Not reported
Removal Action Certification: N
Action Included Fencing: Not reported
Well Decommissioned: Not reported
Action Included Capping: Not reported
Liquids Treated (Gals): 0
DAVE’S AUTO SERVICE (Continued) S102860941
TC7493604.2s Page 277
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Comments: actions have been completed, that all acceptable engineering Comments Date: 07302003
Comments: The Department has determined that all appropriate response Comments Date: 07302003
Comments: residential standard. All confirmation samples were below the Comments Date: 06272003
Comments: a permitted disposal facility. Cleanup was completed to a Comments Date: 06272003
Comments: Lead and cadmium-contaminated soil was excavated and removed to Comments Date: 06272003
Comments: Mailed PA package to U.S. EPA.
Comments Date: 06231999
Comments: lead as high as 11,000 ppm.
Comments Date: 05251999
Comments: Performed site visit as part of PA, and took samples. Found Comments Date: 05251999
Comments: ppm. of lead.
Comments Date: 04262001
Comments: Samples taken at the site using an XRF. Found up to 38,000 Comments Date: 04262001
Comments: of this soil to a permitted disposal facility.
Comments Date: 04102003
Comments: and cadmium from this site and adjacent areas and the disposal Comments Date: 04102003
Comments: approximately 180 cubic yards of soil contaminated with lead Comments Date: 04102003
Comments: The Removal Action Workplan was approved for the excavation of Comments Date: 04102003
Comments: amount excavated was 224 tons, or an estimated 172 cubic yards.
Comments Date: 06272003
adjacent property immediately east of the site.
J.T. Diesel. The employees of Chi Li Auto Center park on an parked on the Site, in the eastern portion of the site, east of vacant. The cars that were being serviced by J.T. Diesel were northeast corner of the Site. This portion of the site is now former sump, and southwest of the section of bare soil in the Auto Center, northeast of Conceptions Retail Store, south of the Depot was there prior to that. J.T. Diesel was east of Chi Li a J.T. Diesel in the northern portion of the site, and Brake is in the southeast portion of the Site. Previously, there was and Vacuum shop. The parking lot for Conceptions Retail Store Properties, 2002). Conceptions Retail Store used to be a Sewing 2) Import Auto Tech, and 3) Chi Li Auto Center (Parker
1) Conceptions Retail Store (a toy and baby supply store), Three businesses currently operate on the Site. These include:
Not reported
Mr. Tucker for nonpayment of rent.
agreement for the radiator shop. In 1993, Mr. Storrs evicted Mr. Storrs and Mr. Tucker entered into a 20-year sublease a radiator repair shop. After the sublease expired in 1993, to 1986, and again from 1987 to 1993, and used the building as subleased a portion of this property from Mr. Storrs from 1985 and Lloyd and Rose E. Parsons Trust since 1970. David Tucker Background Info: Richard Storrs has leased the entire property from Lloyd Parson Alternate City,St,Zip: SANTEE, CA 92071
Alternate Address: 10438 MISSION GORGE ROAD
Unknown Type: 0
DAVE’S AUTO SERVICE (Continued) S102860941
TC7493604.2s Page 278
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Comments Date: 12222000
Comments: No action taken as yet. SD County and RWQCB notified.
Comments Date: 12201995
Comments: residence across alley way in rear.
Comments Date: 12201995
Comments: leakage on-site running off-site at rear. Private Comments Date: 12201995
Comments: by previous operator (Storr’s Auto Repair) indications of Comments Date: 12201995
Comments: Radiator repair process tank (above ground) possibly used Comments Date: 12201995
Comments: Not reported
Comments Date: 12201995
Comments: Charles Ferguson (619) 449-5969
Comments Date: 12201995
Comments: Consultant: Safety Compliance Inc
Comments Date: 12201995
Comments: Dave’s Auto Service: Dave Tucker (619) 562-5432 Comments Date: 12201995
Comments: Contacts:
Comments Date: 12201995
Comments: Not reported
Comments Date: 12201995
Comments: PEA required letter sent to Dave’s Auto Service.
Comments Date: 12201995
Comments: for this site.
Comments Date: 11152002
Comments: report as part of the second phase of a remedial investigation Comments Date: 11152002
Comments: Through its contractor DTSC completed a site investigation Comments Date: 11152002
Comments: Lab reports show Lead contamination in soil, 971 mg/kg.
Comments Date: 11081995
Comments: Release discovered, date of release is unknown.
Comments Date: 11081995
Comments: the RAW. With minor variations, DTSC has approved it.
Comments Date: 10222002
Comments: Tetra Tech, the contractor, submitted the latest version of Comments Date: 10222002
Comments: Changed the site status from PEAR to PEAP.
Comments Date: 10191998
Comments: Removal Action Workplan.
Comments Date: 09252001
Comments: Tetra-tech will take more surface samples and prepare a Comments Date: 09252001
Comments: sampling. Found up to approximately 1,000 mg./kg lead.
Comments Date: 09252001
Comments: DTSC’s contractor Tetra-tech submitted a report of soil Comments Date: 09252001
Comments: It was approved by U.S.EPA on August 2, 1999.
Comments Date: 08021999
Comments: Completed a Preliminary Assessment with sampling for this site.
Comments Date: 08021999
Comments: action is necessary.
Comments Date: 07302003
Comments: practices were implemented and that no further removal/remedial Comments Date: 07302003
DAVE’S AUTO SERVICE (Continued) S102860941
TC7493604.2s Page 279
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Special Programs Name: Not reported
Special Programs Code: Not reported
Alternate Name: Not reported
Alternate Name: DAVE’S AUTO SERVICE
ID Value: 400713
ID Name: CALSTARS CODE
Comments: action levels of 147 mg/kg lead and 1.4 mg/kg cadmium. Total Comments Date: 06272003
Comments: I &SE Determination issued.
DAVE’S AUTO SERVICE (Continued) S102860941
Completed Date: 09/03/2009
Completed Document Type: Letter - Notice
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Completed Info:
Alias Type: Envirostor ID Number
Alias Name: 37750003
Alias Type: Project Code (Site Code)
Alias Name: 400713
Alias Type: EPA (FRS #)
Alias Name: 110033616638
Potential Description: SOIL
Confirmed COC: NONE SPECIFIED
Potential COC : Lead
Past Use: VEHICLE MAINTENANCE
APN: NONE SPECIFIED
Longitude: -116.9699
Latitude: 32.83868
Funding: Orphan Funds
Restricted Use: NO
Status Date: 07/30/2003
Status: Certified
Special Program Status: Not reported
Senate: 40
Assembly: 75
Site Mgmt. Req.: NONE SPECIFIED
Site Code: 400713
Division Branch: Cleanup Cypress
Supervisor: Douglas Bautista
Project Manager: Joseph Cully
Lead Agency Description: DTSC - Site Cleanup Program
Cleanup Oversight Agencies: SMBRP
National Priorities List: NO
Acres: 0.55
Site Type Detail: State Response or NPL
Site Type: State Response
Facility ID: 37750003
City,State,Zip: SANTEE, CA 92071
Address: 10438 MISSION GORGE ROAD
Name: DAVE’S AUTO SERVICE
RESPONSE:
3486 ft. Site 2 of 2 in cluster I
0.660 mi.
Relative:
Higher
Actual:
363 ft.
1/2-1 SANTEE, CA 92071 LIENS
SSE 10438 MISSION GORGE ROAD ENVIROSTOR N/A
I33 DAVE’S AUTO SERVICE RESPONSE S108744490
TC7493604.2s Page 280
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Completed Document Type: Site Characterization Report
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Fact sheet dated February, 2003 was released in English and Spanish.
Completed Date: 02/28/2003
Completed Document Type: Fact Sheets
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Field visit was performed on October 15, 2004.
Completed Date: 10/15/2004
Completed Document Type: Fieldwork
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Consultant sent final RI workplan, dated May 3, 2001, to DTSC.
Completed Date: 05/03/2001
Completed Document Type: Remedial Investigation Workplan Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
was approved by U.S. EPA on August 2, 1999.
Comments: Completed a Preliminary Assessment with sampling for this site. It Completed Date: 08/02/1999
Completed Document Type: Preliminary Assessment Report
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Not reported
Completed Date: 07/31/2001
Completed Document Type: Fact Sheets
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
contamination in soil, 971 mg/kg.
Comments: Release discovered, date of release is unknown. Lab reports show Lead Completed Date: 11/08/1995
Completed Document Type: * Discovery
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: I &SE Determination issued.
Completed Date: 12/22/2000
Completed Document Type: Imminent and/or Subst. Endangerment Determination Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
implemented and that no further removal/remedial action is necessary. have been completed, that all acceptable engineering practices were Comments: The Department has determined that all appropriate response actions Completed Date: 07/30/2003
Completed Document Type: Certification
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Not reported
DAVE’S AUTO SERVICE (Continued) S108744490
TC7493604.2s Page 281
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Schedule Revised Date: Not reported
Schedule Due Date: Not reported
Schedule Document Type: Not reported
Schedule Sub Area Name: Not reported
Schedule Area Name: Not reported
Future Due Date: Not reported
Future Document Type: Not reported
Future Sub Area Name: Not reported
Future Area Name: Not reported
as yet. SD County and RWQCB notified.
at rear. Private residence across alley way in rear. No action taken (Storr’s Auto Repair) indications of leakage on-site running off-site process tank (above ground) possibly used by previous operator Compliance Inc Charles Ferguson (619) 449-5969 Radiator repair Auto Service: Dave Tucker (619) 562-5432 Consultant: Safety Comments: PEA required letter sent to Dave’s Auto Service. Contacts: Dave’s Completed Date: 12/20/1995
Completed Document Type: Site Screening
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
tons, or an estimated 172 cubic yards.
147 mg/kg lead and 1.4 mg/kg cadmium. Total amount excavated was 224 standard. All confirmation samples were below the action levels of permitted disposal facility. Cleanup was completed to a residential Comments: Lead and cadmium-contaminated soil was excavated and removed to a Completed Date: 06/27/2003
Completed Document Type: Removal Action Completion Report Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
soil to a permitted disposal facility.
cadmium from this site and adjacent areas and the disposal of this approximately 180 cubic yards of soil contaminated with lead and Comments: The Removal Action Workplan was approved for the excavation of Completed Date: 04/10/2003
Completed Document Type: Removal Action Workplan
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Not reported
Completed Date: 05/24/2010
Completed Document Type: Lien
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
limitations have been exceeded.
is releasing the lien from the property because the statute of Comments: Even though the property owners have not paid for DTSC’s costs, DTSC Completed Date: 02/07/2013
Completed Document Type: Lien Satisfaction
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Approved Site Investigation Report.
Completed Date: 11/15/2002
DAVE’S AUTO SERVICE (Continued) S108744490
TC7493604.2s Page 282
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Comments: I &SE Determination issued.
Completed Date: 12/22/2000
Completed Document Type: Imminent and/or Subst. Endangerment Determination Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
implemented and that no further removal/remedial action is necessary. have been completed, that all acceptable engineering practices were Comments: The Department has determined that all appropriate response actions Completed Date: 07/30/2003
Completed Document Type: Certification
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Not reported
Completed Date: 09/03/2009
Completed Document Type: Letter - Notice
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Completed Info:
Alias Type: Envirostor ID Number
Alias Name: 37750003
Alias Type: Project Code (Site Code)
Alias Name: 400713
Alias Type: EPA (FRS #)
Alias Name: 110033616638
Potential Description: SOIL
Confirmed COC: NONE SPECIFIED
Potential COC: Lead
Past Use: VEHICLE MAINTENANCE
APN: NONE SPECIFIED
Longitude: -116.9699
Latitude: 32.83868
Funding: Orphan Funds
Site Mgmt Req: NONE SPECIFIED
Restricted Use: NO
Special Program: Not reported
Senate: 40
Assembly: 75
Division Branch: Cleanup Cypress
Supervisor: Douglas Bautista
Program Manager: Joseph Cully
Lead Agency: SMBRP
Regulatory Agencies: SMBRP
NPL: NO
Acres: 0.55
Site Type Detailed: State Response or NPL
Site Type: State Response
Site Code: 400713
Status Date: 07/30/2003
Status: Certified
Facility ID: 37750003
City,State,Zip: SANTEE, CA 92071
Address: 10438 MISSION GORGE ROAD
Name: DAVE’S AUTO SERVICE
ENVIROSTOR:
DAVE’S AUTO SERVICE (Continued) S108744490
TC7493604.2s Page 283
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Comments: Not reported
Completed Date: 05/24/2010
Completed Document Type: Lien
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
limitations have been exceeded.
is releasing the lien from the property because the statute of Comments: Even though the property owners have not paid for DTSC’s costs, DTSC Completed Date: 02/07/2013
Completed Document Type: Lien Satisfaction
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Approved Site Investigation Report.
Completed Date: 11/15/2002
Completed Document Type: Site Characterization Report
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Fact sheet dated February, 2003 was released in English and Spanish.
Completed Date: 02/28/2003
Completed Document Type: Fact Sheets
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Field visit was performed on October 15, 2004.
Completed Date: 10/15/2004
Completed Document Type: Fieldwork
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Consultant sent final RI workplan, dated May 3, 2001, to DTSC.
Completed Date: 05/03/2001
Completed Document Type: Remedial Investigation Workplan Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
was approved by U.S. EPA on August 2, 1999.
Comments: Completed a Preliminary Assessment with sampling for this site. It Completed Date: 08/02/1999
Completed Document Type: Preliminary Assessment Report
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Not reported
Completed Date: 07/31/2001
Completed Document Type: Fact Sheets
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
contamination in soil, 971 mg/kg.
Comments: Release discovered, date of release is unknown. Lab reports show Lead Completed Date: 11/08/1995
Completed Document Type: * Discovery
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
DAVE’S AUTO SERVICE (Continued) S108744490
TC7493604.2s Page 284
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
APNS: Not reported
Amount Remaining: Not reported
Lien Amount: $502,417.55
Completed: 05/24/2010
Site Type: STATE RESPONSE OR NPL
Site Status: CERTIFIED
Date Satisfied: 2/7/2013
If Satisfied: YES
Project Code: 400713
Project Mgr: JOSEPH CULLY
Longitude: -116.96990
Latitude: 32.838684
Envirostor Id: 37750003
City,State,Zip: SANTEE, CA 92071
Name: DAVE’S AUTO SERVICE
LIENS:
Schedule Revised Date: Not reported
Schedule Due Date: Not reported
Schedule Document Type: Not reported
Schedule Sub Area Name: Not reported
Schedule Area Name: Not reported
Future Due Date: Not reported
Future Document Type: Not reported
Future Sub Area Name: Not reported
Future Area Name: Not reported
as yet. SD County and RWQCB notified.
at rear. Private residence across alley way in rear. No action taken (Storr’s Auto Repair) indications of leakage on-site running off-site process tank (above ground) possibly used by previous operator Compliance Inc Charles Ferguson (619) 449-5969 Radiator repair Auto Service: Dave Tucker (619) 562-5432 Consultant: Safety Comments: PEA required letter sent to Dave’s Auto Service. Contacts: Dave’s Completed Date: 12/20/1995
Completed Document Type: Site Screening
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
tons, or an estimated 172 cubic yards.
147 mg/kg lead and 1.4 mg/kg cadmium. Total amount excavated was 224 standard. All confirmation samples were below the action levels of permitted disposal facility. Cleanup was completed to a residential Comments: Lead and cadmium-contaminated soil was excavated and removed to a Completed Date: 06/27/2003
Completed Document Type: Removal Action Completion Report Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
soil to a permitted disposal facility.
cadmium from this site and adjacent areas and the disposal of this approximately 180 cubic yards of soil contaminated with lead and Comments: The Removal Action Workplan was approved for the excavation of Completed Date: 04/10/2003
Completed Document Type: Removal Action Workplan
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
DAVE’S AUTO SERVICE (Continued) S108744490
TC7493604.2s Page 285
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
certified.
contaminated. Teh Removal Action was completed, andt he site has been Parsons property and an adjacent property which had also been Workplan, for the removal of soil contaminated with lead for both the Investigation was performed at the site, and later a Removal Action Storrs evicted Mr. Tucker for nonpayment of rent. A Remedial into a 20-year sublease agreement for the radiator shop. In 1993, Mr.
After the sublease expired in 1993, Mr. Storrs and Mr. Tucker entered from 1987 to 1993, and used the building as a radiator repair shop. portion of this property from Mr. Storrs from 1985 to 1986, and again Lloyd and Rose E. Parsons Trust since 1970. David Tucker subleased a Description: Richard Storrs has leased the entire property from Lloyd Parson and DAVE’S AUTO SERVICE (Continued) S108744490
Longitude: -116.96666667
Latitude: 32.8375
improvements remain on the property.
commercial area. Other than the restaurant building, no other military headquarters structure, the entire site has been developed into a now used as a restaurant. Except for a small field to the south of the for Army trucks. The former headquarters building still exists, and is witnesses of the camp suggested that the site was used as a fuel depot tents located to the south of the headquarters building. First-hand the east side of the headquarters building. There may also have been the camp lived in tents, which were located on the north side and on 1915, as a headquarters building. The quartermaster units stationed at 1943. The Army used an existing structure, built in approximately sometime in 1941. There are no records of the camp’s existence after Feature Description: The Army acquired the use of the Santee Camp through unknown means Project Required: No
NPL Status: Not reported
Has Projects: No
Eligibility: Eligible
EMS Map Link: https://fudsportal.usace.army.mil/ems/inventory/map?id=62916 establishments.
Current Owner: PRIV: PRIVATE Most of the site is now occupied by various commercial Status: Properties without projects
USACE District: Los Angeles District (SPL)
USACE Division: SPD
Object ID: 9501
County: SAN DIEGO
State: CA
City: SANTEE
FUDS Number: J09CA7323
Name: ARMY CAMP (SANTEE)
Congressional District Number: 48
Installation ID: CA99799FA35200
EPA Region: 09
FUDS:
4222 ft. Site 1 of 2 in cluster J
0.800 mi.
Relative:
Higher
Actual:
376 ft.
1/2-1 SANTEE, CA
SE N/A
J34 ARMY CAMP (SANTEE) FUDS 1024904003
TC7493604.2s Page 286
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Schedule Revised Date: Not reported
Schedule Due Date: Not reported
Schedule Document Type: Not reported
Schedule Sub Area Name: Not reported
Schedule Area Name: Not reported
Future Due Date: Not reported
Future Document Type: Not reported
Future Sub Area Name: Not reported
Future Area Name: Not reported
Comments: Not reported
Completed Date: 09/21/1999
Completed Document Type: Inventory Project Report (INPR) Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Completed Info:
Alias Type: Envirostor ID Number
Alias Name: 80000969
Alias Type: INPR
Alias Name: J09CA7323
Alias Type: Federal Facility ID
Alias Name: CA99799FA35200
Potential Description: NONE SPECIFIED
Confirmed COC: NONE SPECIFIED
Potential COC: NONE SPECIFIED
Past Use: NONE SPECIFIED
APN: NONE SPECIFIED
Longitude: -116.9666
Latitude: 32.8375
Funding: DERA
Site Mgmt Req: NONE SPECIFIED
Restricted Use: NO
Special Program: Not reported
Senate: 40
Assembly: 75
Division Branch: Cleanup Cypress
Supervisor: Douglas Bautista
Program Manager: Not reported
Lead Agency: SMBRP
Regulatory Agencies: SMBRP
NPL: NO
Acres: Not reported
Site Type Detailed: FUDS
Site Type: Military Evaluation
Site Code: Not reported
Status Date: 07/01/2005
Status: Inactive - Needs Evaluation
Facility ID: 80000969
City,State,Zip: SANTEE, CA
Address: Not reported
Name: SANTEE ARMY CAMP
ENVIROSTOR:
4232 ft. Site 2 of 2 in cluster J
0.802 mi.
Relative:
Higher
Actual:
376 ft.
1/2-1 SANTEE, CA
SE N/A
J35 SANTEE ARMY CAMP ENVIROSTOR S107737292
TC7493604.2s Page 287
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Schedule Sub Area Name: Not reported
Schedule Area Name: Not reported
Future Due Date: Not reported
Future Document Type: Not reported
Future Sub Area Name: Not reported
Future Area Name: Not reported
Comments: Not reported
Completed Date: 09/30/1998
Completed Document Type: Phase I Verification
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Comments: Not reported
Completed Date: 03/31/2004
Completed Document Type: Phase 1
Completed Sub Area Name: Not reported
Completed Area Name: PROJECT WIDE
Completed Info:
Alias Type: Envirostor ID Number
Alias Name: 71003382
Alias Type: EPA Identification Number
Alias Name: CAL000178492
Potential Description: NONE SPECIFIED
Confirmed COC: NONE SPECIFIED
Potential COC: NONE SPECIFIED
Past Use: NONE SPECIFIED
APN: NONE SPECIFIED
Longitude: -116.9574
Latitude: 32.84870
Funding: Not reported
Site Mgmt Req: NONE SPECIFIED
Restricted Use: NO
Special Program: Not reported
Senate: 40
Assembly: 75
Division Branch: Cleanup Cypress
Supervisor: Not reported
Program Manager: Not reported
Lead Agency: NONE SPECIFIED
Regulatory Agencies: NONE SPECIFIED
NPL: NO
Acres: Not reported
Site Type Detailed: Tiered Permit
Site Type: Tiered Permit
Site Code: Not reported
Status Date: 09/30/1998
Status: No Action Required
Facility ID: 71003382
City,State,Zip: SANTEE, CA 92071
Address: 9484 MISSION PARK PLACE
Name: KETEMA PROCESS EQUIPMENT CO., C/O BAKER PROCESS
ENVIROSTOR:
5007 ft.
0.948 mi.
Relative:
Higher
Actual:
356 ft.
1/2-1 SANTEE, CA 92071
East 9484 MISSION PARK PLACE N/A
36 KETEMA PROCESS EQUIPMENT CO., C/O BAKER PROCESS S118757455 ENVIROSTOR TC7493604.2s Page 288
Map ID MAP FINDINGS
Direction
Distance EDR ID Number
Elevation Site Database(s) EPA ID Number
Schedule Revised Date: Not reported
Schedule Due Date: Not reported
Schedule Document Type: Not reported
KETEMA PROCESS EQUIPMENT CO., C/O BAKER PROCESS (Continued) S118757455 TC7493604.2s Page 289
ORPHAN SUMMARY
City EDR ID Site Name Site Address Zip Database(s)Count: 1 records.LAKESIDE S126984237 KEPHART DUMP SAN DIEGO EUCALYPTUS LANDS 92040 SWF/LF TC7493604.2s Page 290
To maintain currency of the following federal and state databases, EDR contacts the appropriate governmental agency on a monthly or quarterly basis, as required.
Number of Days to Update: Provides confirmation that EDR is reporting records that have been updated within 90 days from the date the government agency made the information available to the public.
STANDARD ENVIRONMENTAL RECORDS
Lists of Federal NPL (Superfund) sites
NPL: National Priority List
National Priorities List (Superfund). The NPL is a subset of CERCLIS and identifies over 1,200 sites for priority cleanup under the Superfund Program. NPL sites may encompass relatively large areas. As such, EDR provides polygon coverage for over 1,000 NPL site boundaries produced by EPA’s Environmental Photographic Interpretation Center (EPIC) and regional EPA offices.
Date of Government Version: 09/19/2023
Date Data Arrived at EDR: 10/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 16
Source: EPA
Telephone: N/A
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Quarterly
NPL Site Boundaries
Sources:
EPA’s Environmental Photographic Interpretation Center (EPIC) Telephone: 202-564-7333
EPA Region 1 EPA Region 6
Telephone 617-918-1143 Telephone: 214-655-6659
EPA Region 3 EPA Region 7
Telephone 215-814-5418 Telephone: 913-551-7247
EPA Region 4 EPA Region 8
Telephone 404-562-8033 Telephone: 303-312-6774
EPA Region 5 EPA Region 9
Telephone 312-886-6686 Telephone: 415-947-4246
EPA Region 10
Telephone 206-553-8665
Proposed NPL: Proposed National Priority List Sites
A site that has been proposed for listing on the National Priorities List through the issuance of a proposed rule in the Federal Register. EPA then accepts public comments on the site, responds to the comments, and places on the NPL those sites that continue to meet the requirements for listing.
Date of Government Version: 09/19/2023
Date Data Arrived at EDR: 10/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 16
Source: EPA
Telephone: N/A
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Quarterly
NPL LIENS: Federal Superfund Liens
Federal Superfund Liens. Under the authority granted the USEPA by CERCLA of 1980, the USEPA has the authority to file liens against real property in order to recover remedial action expenditures or when the property owner received notification of potential liability. USEPA compiles a listing of filed notices of Superfund Liens.
TC7493604.2s Page GR-1
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 10/15/1991
Date Data Arrived at EDR: 02/02/1994
Date Made Active in Reports: 03/30/1994
Number of Days to Update: 56
Source: EPA
Telephone: 202-564-4267
Last EDR Contact: 08/15/2011
Next Scheduled EDR Contact: 11/28/2011
Data Release Frequency: No Update Planned
Lists of Federal Delisted NPL sites
Delisted NPL: National Priority List Deletions
The National Oil and Hazardous Substances Pollution Contingency Plan (NCP) establishes the criteria that the EPA uses to delete sites from the NPL. In accordance with 40 CFR 300.425.(e), sites may be deleted from the NPL where no further response is appropriate.
Date of Government Version: 09/19/2023
Date Data Arrived at EDR: 10/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 16
Source: EPA
Telephone: N/A
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Quarterly
Lists of Federal sites subject to CERCLA removals and CERCLA orders FEDERAL FACILITY: Federal Facility Site Information listing A listing of National Priority List (NPL) and Base Realignment and Closure (BRAC) sites found in the Comprehensive Environmental Response, Compensation and Liability Information System (CERCLIS) Database where EPA Federal Facilities Restoration and Reuse Office is involved in cleanup activities.
Date of Government Version: 06/23/2023
Date Data Arrived at EDR: 06/23/2023
Date Made Active in Reports: 09/20/2023
Number of Days to Update: 89
Source: Environmental Protection Agency
Telephone: 703-603-8704
Last EDR Contact: 09/26/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Varies
SEMS: Superfund Enterprise Management System
SEMS (Superfund Enterprise Management System) tracks hazardous waste sites, potentially hazardous waste sites, and remedial activities performed in support of EPA’s Superfund Program across the United States. The list was formerly know as CERCLIS, renamed to SEMS by the EPA in 2015. The list contains data on potentially hazardous waste sites that have been reported to the USEPA by states, municipalities, private companies and private persons, pursuant to Section 103 of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA).
This dataset also contains sites which are either proposed to or on the National Priorities List (NPL) and the sites which are in the screening and assessment phase for possible inclusion on the NPL.
Date of Government Version: 09/19/2023
Date Data Arrived at EDR: 10/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 16
Source: EPA
Telephone: 800-424-9346
Last EDR Contact: 11/02/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: Quarterly
Lists of Federal CERCLA sites with NFRAP
SEMS-ARCHIVE: Superfund Enterprise Management System Archive TC7493604.2s Page GR-2
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
SEMS-ARCHIVE (Superfund Enterprise Management System Archive) tracks sites that have no further interest under the Federal Superfund Program based on available information. The list was formerly known as the CERCLIS-NFRAP, renamed to SEMS ARCHIVE by the EPA in 2015. EPA may perform a minimal level of assessment work at a site while it is archived if site conditions change and/or new information becomes available. Archived sites have been removed and archived from the inventory of SEMS sites. Archived status indicates that, to the best of EPA’s knowledge, assessment at a site has been completed and that EPA has determined no further steps will be taken to list the site on the National Priorities List (NPL), unless information indicates this decision was not appropriate or other considerations require a recommendation for listing at a later time. The decision does not necessarily mean that there is no hazard associated with a given site; it only means that. based upon available information, the location is not judged to be potential NPL site.
Date of Government Version: 09/19/2023
Date Data Arrived at EDR: 10/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 16
Source: EPA
Telephone: 800-424-9346
Last EDR Contact: 11/02/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: Quarterly
Lists of Federal RCRA facilities undergoing Corrective Action CORRACTS: Corrective Action Report
CORRACTS identifies hazardous waste handlers with RCRA corrective action activity.
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/31/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 14
Source: EPA
Telephone: 800-424-9346
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
Lists of Federal RCRA TSD facilities
RCRA-TSDF: RCRA - Treatment, Storage and Disposal
RCRAInfo is EPA’s comprehensive information system, providing access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. The database includes selective information on sites which generate, transport, store, treat and/or dispose of hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA). Transporters are individuals or entities that move hazardous waste from the generator offsite to a facility that can recycle, treat, store, or dispose of the waste. TSDFs treat, store, or dispose of the waste.
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/31/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 14
Source: Environmental Protection Agency
Telephone: (415) 495-8895
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
Lists of Federal RCRA generators
RCRA-LQG: RCRA - Large Quantity Generators
RCRAInfo is EPA’s comprehensive information system, providing access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. The database includes selective information on sites which generate, transport, store, treat and/or dispose of hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA). Large quantity generators (LQGs) generate over 1,000 kilograms (kg) of hazardous waste, or over 1 kg of acutely hazardous waste per month.
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/31/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 14
Source: Environmental Protection Agency
Telephone: (415) 495-8895
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
TC7493604.2s Page GR-3
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
RCRA-SQG: RCRA - Small Quantity Generators
RCRAInfo is EPA’s comprehensive information system, providing access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. The database includes selective information on sites which generate, transport, store, treat and/or dispose of hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA). Small quantity generators (SQGs) generate between 100 kg and 1,000 kg of hazardous waste per month.
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/31/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 14
Source: Environmental Protection Agency
Telephone: (415) 495-8895
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
RCRA-VSQG: RCRA - Very Small Quantity Generators (Formerly Conditionally Exempt Small Quantity Generators) RCRAInfo is EPA’s comprehensive information system, providing access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. The database includes selective information on sites which generate, transport, store, treat and/or dispose of hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA). Very small quantity generators (VSQGs) generate less than 100 kg of hazardous waste, or less than 1 kg of acutely hazardous waste per month.
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/31/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 14
Source: Environmental Protection Agency
Telephone: (415) 495-8895
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
Federal institutional controls / engineering controls registries LUCIS: Land Use Control Information System
LUCIS contains records of land use control information pertaining to the former Navy Base Realignment and Closure properties.
Date of Government Version: 08/03/2023
Date Data Arrived at EDR: 08/07/2023
Date Made Active in Reports: 10/10/2023
Number of Days to Update: 64
Source: Department of the Navy
Telephone: 843-820-7326
Last EDR Contact: 11/02/2023
Next Scheduled EDR Contact: 02/19/2024
Data Release Frequency: Varies
US ENG CONTROLS: Engineering Controls Sites List
A listing of sites with engineering controls in place. Engineering controls include various forms of caps, building foundations, liners, and treatment methods to create pathway elimination for regulated substances to enter environmental media or effect human health.
Date of Government Version: 08/21/2023
Date Data Arrived at EDR: 08/21/2023
Date Made Active in Reports: 11/07/2023
Number of Days to Update: 78
Source: Environmental Protection Agency
Telephone: 703-603-0695
Last EDR Contact: 08/21/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Varies
US INST CONTROLS: Institutional Controls Sites List
A listing of sites with institutional controls in place. Institutional controls include administrative measures, such as groundwater use restrictions, construction restrictions, property use restrictions, and post remediation care requirements intended to prevent exposure to contaminants remaining on site. Deed restrictions are generally required as part of the institutional controls.
Date of Government Version: 08/21/2023
Date Data Arrived at EDR: 08/21/2023
Date Made Active in Reports: 11/07/2023
Number of Days to Update: 78
Source: Environmental Protection Agency
Telephone: 703-603-0695
Last EDR Contact: 08/21/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Varies
TC7493604.2s Page GR-4
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Federal ERNS list
ERNS: Emergency Response Notification System
Emergency Response Notification System. ERNS records and stores information on reported releases of oil and hazardous substances.
Date of Government Version: 06/12/2023
Date Data Arrived at EDR: 06/20/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 55
Source: National Response Center, United States Coast Guard Telephone: 202-267-2180
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
Lists of state- and tribal (Superfund) equivalent sites RESPONSE: State Response Sites
Identifies confirmed release sites where DTSC is involved in remediation, either in a lead or oversight capacity.
These confirmed release sites are generally high-priority and high potential risk.
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/25/2023
Date Made Active in Reports: 10/11/2023
Number of Days to Update: 78
Source: Department of Toxic Substances Control
Telephone: 916-323-3400
Last EDR Contact: 10/24/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Quarterly
Lists of state- and tribal hazardous waste facilities
ENVIROSTOR: EnviroStor Database
The Department of Toxic Substances Control’s (DTSC’s) Site Mitigation and Brownfields Reuse Program’s (SMBRP’s) EnviroStor database identifes sites that have known contamination or sites for which there may be reasons to investigate further. The database includes the following site types: Federal Superfund sites (National Priorities List (NPL)); State Response, including Military Facilities and State Superfund; Voluntary Cleanup; and School sites. EnviroStor provides similar information to the information that was available in CalSites, and provides additional site information, including, but not limited to, identification of formerly-contaminated properties that have been released for reuse, properties where environmental deed restrictions have been recorded to prevent inappropriate land uses, and risk characterization information that is used to assess potential impacts to public health and the environment at contaminated sites.
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/25/2023
Date Made Active in Reports: 10/11/2023
Number of Days to Update: 78
Source: Department of Toxic Substances Control
Telephone: 916-323-3400
Last EDR Contact: 10/24/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Quarterly
Lists of state and tribal landfills and solid waste disposal facilities SWF/LF (SWIS): Solid Waste Information System
Active, Closed and Inactive Landfills. SWF/LF records typically contain an inve ntory of solid waste disposal facilities or landfills. These may be active or i nactive facilities or open dumps that failed to meet RCRA Section 4004 criteria for solid waste landfills or disposal sites.
Date of Government Version: 08/07/2023
Date Data Arrived at EDR: 08/08/2023
Date Made Active in Reports: 10/26/2023
Number of Days to Update: 79
Source: Department of Resources Recycling and Recovery
Telephone: 916-341-6320
Last EDR Contact: 11/07/2023
Next Scheduled EDR Contact: 02/19/2024
Data Release Frequency: Quarterly
Lists of state and tribal leaking storage tanks
TC7493604.2s Page GR-5
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
LUST REG 6L: Leaking Underground Storage Tank Case Listing For more current information, please refer to the State Water Resources Control Board’s LUST database.
Date of Government Version: 09/09/2003
Date Data Arrived at EDR: 09/10/2003
Date Made Active in Reports: 10/07/2003
Number of Days to Update: 27
Source: California Regional Water Quality Control Board Lahontan Region (6) Telephone: 530-542-5572
Last EDR Contact: 09/12/2011
Next Scheduled EDR Contact: 12/26/2011
Data Release Frequency: No Update Planned
LUST REG 9: Leaking Underground Storage Tank Report
Orange, Riverside, San Diego counties. For more current information, please refer to the State Water Resources Control Board’s LUST database.
Date of Government Version: 03/01/2001
Date Data Arrived at EDR: 04/23/2001
Date Made Active in Reports: 05/21/2001
Number of Days to Update: 28
Source: California Regional Water Quality Control Board San Diego Region (9) Telephone: 858-637-5595
Last EDR Contact: 09/26/2011
Next Scheduled EDR Contact: 01/09/2012
Data Release Frequency: No Update Planned
LUST REG 8: Leaking Underground Storage Tanks
California Regional Water Quality Control Board Santa Ana Region (8). For more current information, please refer to the State Water Resources Control Board’s LUST database.
Date of Government Version: 02/14/2005
Date Data Arrived at EDR: 02/15/2005
Date Made Active in Reports: 03/28/2005
Number of Days to Update: 41
Source: California Regional Water Quality Control Board Santa Ana Region (8) Telephone: 909-782-4496
Last EDR Contact: 08/15/2011
Next Scheduled EDR Contact: 11/28/2011
Data Release Frequency: No Update Planned
LUST REG 7: Leaking Underground Storage Tank Case Listing Leaking Underground Storage Tank locations. Imperial, Riverside, San Diego, Santa Barbara counties.
Date of Government Version: 02/26/2004
Date Data Arrived at EDR: 02/26/2004
Date Made Active in Reports: 03/24/2004
Number of Days to Update: 27
Source: California Regional Water Quality Control Board Colorado River Basin Region (7) Telephone: 760-776-8943
Last EDR Contact: 08/01/2011
Next Scheduled EDR Contact: 11/14/2011
Data Release Frequency: No Update Planned
LUST REG 5: Leaking Underground Storage Tank Database
Leaking Underground Storage Tank locations. Alameda, Alpine, Amador, Butte, Colusa, Contra Costa, Calveras, El Dorado, Fresno, Glenn, Kern, Kings, Lake, Lassen, Madera, Mariposa, Merced, Modoc, Napa, Nevada, Placer, Plumas, Sacramento, San Joaquin, Shasta, Solano, Stanislaus, Sutter, Tehama, Tulare, Tuolumne, Yolo, Yuba counties.
Date of Government Version: 07/01/2008
Date Data Arrived at EDR: 07/22/2008
Date Made Active in Reports: 07/31/2008
Number of Days to Update: 9
Source: California Regional Water Quality Control Board Central Valley Region (5) Telephone: 916-464-4834
Last EDR Contact: 07/01/2011
Next Scheduled EDR Contact: 10/17/2011
Data Release Frequency: No Update Planned
LUST REG 4: Underground Storage Tank Leak List
Los Angeles, Ventura counties. For more current information, please refer to the State Water Resources Control Board’s LUST database.
Date of Government Version: 09/07/2004
Date Data Arrived at EDR: 09/07/2004
Date Made Active in Reports: 10/12/2004
Number of Days to Update: 35
Source: California Regional Water Quality Control Board Los Angeles Region (4) Telephone: 213-576-6710
Last EDR Contact: 09/06/2011
Next Scheduled EDR Contact: 12/19/2011
Data Release Frequency: No Update Planned
TC7493604.2s Page GR-6
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
LUST REG 3: Leaking Underground Storage Tank Database
Leaking Underground Storage Tank locations. Monterey, San Benito, San Luis Obispo, Santa Barbara, Santa Cruz counties.
Date of Government Version: 05/19/2003
Date Data Arrived at EDR: 05/19/2003
Date Made Active in Reports: 06/02/2003
Number of Days to Update: 14
Source: California Regional Water Quality Control Board Central Coast Region (3) Telephone: 805-542-4786
Last EDR Contact: 07/18/2011
Next Scheduled EDR Contact: 10/31/2011
Data Release Frequency: No Update Planned
LUST REG 2: Fuel Leak List
Leaking Underground Storage Tank locations. Alameda, Contra Costa, Marin, Napa, San Francisco, San Mateo, Santa Clara, Solano, Sonoma counties.
Date of Government Version: 09/30/2004
Date Data Arrived at EDR: 10/20/2004
Date Made Active in Reports: 11/19/2004
Number of Days to Update: 30
Source: California Regional Water Quality Control Board San Francisco Bay Region (2) Telephone: 510-622-2433
Last EDR Contact: 09/19/2011
Next Scheduled EDR Contact: 01/02/2012
Data Release Frequency: No Update Planned
LUST: Leaking Underground Fuel Tank Report (GEOTRACKER) Leaking Underground Storage Tank (LUST) Sites included in GeoTracker. GeoTracker is the Water Boards data management system for sites that impact, or have the potential to impact, water quality in California, with emphasis on groundwater.
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: see region list
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Quarterly
LUST REG 6V: Leaking Underground Storage Tank Case Listing Leaking Underground Storage Tank locations. Inyo, Kern, Los Angeles, Mono, San Bernardino counties.
Date of Government Version: 06/07/2005
Date Data Arrived at EDR: 06/07/2005
Date Made Active in Reports: 06/29/2005
Number of Days to Update: 22
Source: California Regional Water Quality Control Board Victorville Branch Office (6) Telephone: 760-241-7365
Last EDR Contact: 09/12/2011
Next Scheduled EDR Contact: 12/26/2011
Data Release Frequency: No Update Planned
LUST REG 1: Active Toxic Site Investigation
Del Norte, Humboldt, Lake, Mendocino, Modoc, Siskiyou, Sonoma, Trinity counties. For more current information, please refer to the State Water Resources Control Board’s LUST database.
Date of Government Version: 02/01/2001
Date Data Arrived at EDR: 02/28/2001
Date Made Active in Reports: 03/29/2001
Number of Days to Update: 29
Source: California Regional Water Quality Control Board North Coast (1) Telephone: 707-570-3769
Last EDR Contact: 08/01/2011
Next Scheduled EDR Contact: 11/14/2011
Data Release Frequency: No Update Planned
INDIAN LUST R6: Leaking Underground Storage Tanks on Indian Land LUSTs on Indian land in New Mexico and Oklahoma.
Date of Government Version: 04/26/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 6
Telephone: 214-665-6597
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN LUST R5: Leaking Underground Storage Tanks on Indian Land Leaking underground storage tanks located on Indian Land in Michigan, Minnesota and Wisconsin.
TC7493604.2s Page GR-7
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 04/14/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA, Region 5
Telephone: 312-886-7439
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN LUST R10: Leaking Underground Storage Tanks on Indian Land LUSTs on Indian land in Alaska, Idaho, Oregon and Washington.
Date of Government Version: 04/20/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 10
Telephone: 206-553-2857
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN LUST R8: Leaking Underground Storage Tanks on Indian Land LUSTs on Indian land in Colorado, Montana, North Dakota, South Dakota, Utah and Wyoming.
Date of Government Version: 04/19/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 8
Telephone: 303-312-6271
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN LUST R4: Leaking Underground Storage Tanks on Indian Land LUSTs on Indian land in Florida, Mississippi and North Carolina.
Date of Government Version: 04/20/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 4
Telephone: 404-562-8677
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN LUST R1: Leaking Underground Storage Tanks on Indian Land A listing of leaking underground storage tank locations on Indian Land.
Date of Government Version: 04/20/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 1
Telephone: 617-918-1313
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN LUST R7: Leaking Underground Storage Tanks on Indian Land LUSTs on Indian land in Iowa, Kansas, and Nebraska
Date of Government Version: 04/25/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 7
Telephone: 913-551-7003
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN LUST R9: Leaking Underground Storage Tanks on Indian Land LUSTs on Indian land in Arizona, California, New Mexico and Nevada Date of Government Version: 04/19/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: Environmental Protection Agency
Telephone: 415-972-3372
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
TC7493604.2s Page GR-8
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
CPS-SLIC: Statewide SLIC Cases (GEOTRACKER)
Cleanup Program Sites (CPS; also known as Site Cleanups [SC] and formerly known as Spills, Leaks, Investigations, and Cleanups [SLIC] sites) included in GeoTracker. GeoTracker is the Water Boards data management system for sites that impact, or have the potential to impact, water quality in California, with emphasis on groundwater.
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
SLIC REG 1: Active Toxic Site Investigations
The SLIC (Spills, Leaks, Investigations and Cleanup) program is designed to protect and restore water quality from spills, leaks, and similar discharges.
Date of Government Version: 04/03/2003
Date Data Arrived at EDR: 04/07/2003
Date Made Active in Reports: 04/25/2003
Number of Days to Update: 18
Source: California Regional Water Quality Control Board, North Coast Region (1) Telephone: 707-576-2220
Last EDR Contact: 08/01/2011
Next Scheduled EDR Contact: 11/14/2011
Data Release Frequency: No Update Planned
SLIC REG 2: Spills, Leaks, Investigation & Cleanup Cost Recovery Listing The SLIC (Spills, Leaks, Investigations and Cleanup) program is designed to protect and restore water quality from spills, leaks, and similar discharges.
Date of Government Version: 09/30/2004
Date Data Arrived at EDR: 10/20/2004
Date Made Active in Reports: 11/19/2004
Number of Days to Update: 30
Source: Regional Water Quality Control Board San Francisco Bay Region (2) Telephone: 510-286-0457
Last EDR Contact: 09/19/2011
Next Scheduled EDR Contact: 01/02/2012
Data Release Frequency: No Update Planned
SLIC REG 3: Spills, Leaks, Investigation & Cleanup Cost Recovery Listing The SLIC (Spills, Leaks, Investigations and Cleanup) program is designed to protect and restore water quality from spills, leaks, and similar discharges.
Date of Government Version: 05/18/2006
Date Data Arrived at EDR: 05/18/2006
Date Made Active in Reports: 06/15/2006
Number of Days to Update: 28
Source: California Regional Water Quality Control Board Central Coast Region (3) Telephone: 805-549-3147
Last EDR Contact: 07/18/2011
Next Scheduled EDR Contact: 10/31/2011
Data Release Frequency: No Update Planned
SLIC REG 4: Spills, Leaks, Investigation & Cleanup Cost Recovery Listing The SLIC (Spills, Leaks, Investigations and Cleanup) program is designed to protect and restore water quality from spills, leaks, and similar discharges.
Date of Government Version: 11/17/2004
Date Data Arrived at EDR: 11/18/2004
Date Made Active in Reports: 01/04/2005
Number of Days to Update: 47
Source: Region Water Quality Control Board Los Angeles Region (4) Telephone: 213-576-6600
Last EDR Contact: 07/01/2011
Next Scheduled EDR Contact: 10/17/2011
Data Release Frequency: No Update Planned
SLIC REG 5: Spills, Leaks, Investigation & Cleanup Cost Recovery Listing The SLIC (Spills, Leaks, Investigations and Cleanup) program is designed to protect and restore water quality from spills, leaks, and similar discharges.
Date of Government Version: 04/01/2005
Date Data Arrived at EDR: 04/05/2005
Date Made Active in Reports: 04/21/2005
Number of Days to Update: 16
Source: Regional Water Quality Control Board Central Valley Region (5) Telephone: 916-464-3291
Last EDR Contact: 09/12/2011
Next Scheduled EDR Contact: 12/26/2011
Data Release Frequency: No Update Planned
TC7493604.2s Page GR-9
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
SLIC REG 6V: Spills, Leaks, Investigation & Cleanup Cost Recovery Listing The SLIC (Spills, Leaks, Investigations and Cleanup) program is designed to protect and restore water quality from spills, leaks, and similar discharges.
Date of Government Version: 05/24/2005
Date Data Arrived at EDR: 05/25/2005
Date Made Active in Reports: 06/16/2005
Number of Days to Update: 22
Source: Regional Water Quality Control Board, Victorville Branch Telephone: 619-241-6583
Last EDR Contact: 08/15/2011
Next Scheduled EDR Contact: 11/28/2011
Data Release Frequency: No Update Planned
SLIC REG 6L: SLIC Sites
The SLIC (Spills, Leaks, Investigations and Cleanup) program is designed to protect and restore water quality from spills, leaks, and similar discharges.
Date of Government Version: 09/07/2004
Date Data Arrived at EDR: 09/07/2004
Date Made Active in Reports: 10/12/2004
Number of Days to Update: 35
Source: California Regional Water Quality Control Board, Lahontan Region Telephone: 530-542-5574
Last EDR Contact: 08/15/2011
Next Scheduled EDR Contact: 11/28/2011
Data Release Frequency: No Update Planned
SLIC REG 7: SLIC List
The SLIC (Spills, Leaks, Investigations and Cleanup) program is designed to protect and restore water quality from spills, leaks, and similar discharges.
Date of Government Version: 11/24/2004
Date Data Arrived at EDR: 11/29/2004
Date Made Active in Reports: 01/04/2005
Number of Days to Update: 36
Source: California Regional Quality Control Board, Colorado River Basin Region Telephone: 760-346-7491
Last EDR Contact: 08/01/2011
Next Scheduled EDR Contact: 11/14/2011
Data Release Frequency: No Update Planned
SLIC REG 8: Spills, Leaks, Investigation & Cleanup Cost Recovery Listing The SLIC (Spills, Leaks, Investigations and Cleanup) program is designed to protect and restore water quality from spills, leaks, and similar discharges.
Date of Government Version: 04/03/2008
Date Data Arrived at EDR: 04/03/2008
Date Made Active in Reports: 04/14/2008
Number of Days to Update: 11
Source: California Region Water Quality Control Board Santa Ana Region (8) Telephone: 951-782-3298
Last EDR Contact: 09/12/2011
Next Scheduled EDR Contact: 12/26/2011
Data Release Frequency: No Update Planned
SLIC REG 9: Spills, Leaks, Investigation & Cleanup Cost Recovery Listing The SLIC (Spills, Leaks, Investigations and Cleanup) program is designed to protect and restore water quality from spills, leaks, and similar discharges.
Date of Government Version: 09/10/2007
Date Data Arrived at EDR: 09/11/2007
Date Made Active in Reports: 09/28/2007
Number of Days to Update: 17
Source: California Regional Water Quality Control Board San Diego Region (9) Telephone: 858-467-2980
Last EDR Contact: 08/08/2011
Next Scheduled EDR Contact: 11/21/2011
Data Release Frequency: No Update Planned
Lists of state and tribal registered storage tanks
FEMA UST: Underground Storage Tank Listing
A listing of all FEMA owned underground storage tanks.
Date of Government Version: 03/08/2023
Date Data Arrived at EDR: 03/09/2023
Date Made Active in Reports: 05/30/2023
Number of Days to Update: 82
Source: FEMA
Telephone: 202-646-5797
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
TC7493604.2s Page GR-10
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
UST: Active UST Facilities
Active UST facilities gathered from the local regulatory agencies Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: SWRCB
Telephone: 916-341-5851
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Semi-Annually
UST CLOSURE: Proposed Closure of Underground Storage Tank (UST) Cases UST cases that are being considered for closure by either the State Water Resources Control Board or the Executive Director have been posted for a 60-day public comment period. UST Case Closures being proposed for consideration by the State Water Resources Control Board. These are primarily UST cases that meet closure criteria under the decisional framework in State Water Board Resolution No. 92-49 and other Board orders. UST Case Closures proposed for consideration by the Executive Director pursuant to State Water Board Resolution No. 2012-0061. These are cases that meet the criteria of the Low-Threat UST Case Closure Policy. UST Case Closure Review Denials and Approved Orders.
Date of Government Version: 05/31/2023
Date Data Arrived at EDR: 06/02/2023
Date Made Active in Reports: 08/23/2023
Number of Days to Update: 82
Source: State Water Resources Control Board
Telephone: 916-327-7844
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
MILITARY UST SITES: Military UST Sites (GEOTRACKER)
Military ust sites
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
AST: Aboveground Petroleum Storage Tank Facilities
A listing of aboveground storage tank petroleum storage tank locations.
Date of Government Version: 07/06/2016
Date Data Arrived at EDR: 07/12/2016
Date Made Active in Reports: 09/19/2016
Number of Days to Update: 69
Source: California Environmental Protection Agency
Telephone: 916-327-5092
Last EDR Contact: 09/07/2023
Next Scheduled EDR Contact: 12/25/2023
Data Release Frequency: Varies
INDIAN UST R8: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank (UST) database provides information about underground storage tanks on Indian land in EPA Region 8 (Colorado, Montana, North Dakota, South Dakota, Utah, Wyoming and 27 Tribal Nations).
Date of Government Version: 04/20/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 8
Telephone: 303-312-6137
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN UST R7: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank (UST) database provides information about underground storage tanks on Indian land in EPA Region 7 (Iowa, Kansas, Missouri, Nebraska, and 9 Tribal Nations).
Date of Government Version: 04/25/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 7
Telephone: 913-551-7003
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
TC7493604.2s Page GR-11
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
INDIAN UST R1: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank (UST) database provides information about underground storage tanks on Indian land in EPA Region 1 (Connecticut, Maine, Massachusetts, New Hampshire, Rhode Island, Vermont and ten Tribal Nations).
Date of Government Version: 04/20/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA, Region 1
Telephone: 617-918-1313
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN UST R9: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank (UST) database provides information about underground storage tanks on Indian land in EPA Region 9 (Arizona, California, Hawaii, Nevada, the Pacific Islands, and Tribal Nations).
Date of Government Version: 04/19/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 9
Telephone: 415-972-3368
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN UST R6: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank (UST) database provides information about underground storage tanks on Indian land in EPA Region 6 (Louisiana, Arkansas, Oklahoma, New Mexico, Texas and 65 Tribes).
Date of Government Version: 04/26/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 6
Telephone: 214-665-7591
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN UST R5: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank (UST) database provides information about underground storage tanks on Indian land in EPA Region 5 (Michigan, Minnesota and Wisconsin and Tribal Nations).
Date of Government Version: 04/14/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 5
Telephone: 312-886-6136
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN UST R10: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank (UST) database provides information about underground storage tanks on Indian land in EPA Region 10 (Alaska, Idaho, Oregon, Washington, and Tribal Nations).
Date of Government Version: 04/20/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 10
Telephone: 206-553-2857
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INDIAN UST R4: Underground Storage Tanks on Indian Land The Indian Underground Storage Tank (UST) database provides information about underground storage tanks on Indian land in EPA Region 4 (Alabama, Florida, Georgia, Kentucky, Mississippi, North Carolina, South Carolina, Tennessee and Tribal Nations)
Date of Government Version: 04/20/2023
Date Data Arrived at EDR: 05/09/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 66
Source: EPA Region 4
Telephone: 404-562-9424
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
TC7493604.2s Page GR-12
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Lists of state and tribal voluntary cleanup sites
INDIAN VCP R7: Voluntary Cleanup Priority Lisitng
A listing of voluntary cleanup priority sites located on Indian Land located in Region 7.
Date of Government Version: 03/20/2008
Date Data Arrived at EDR: 04/22/2008
Date Made Active in Reports: 05/19/2008
Number of Days to Update: 27
Source: EPA, Region 7
Telephone: 913-551-7365
Last EDR Contact: 07/08/2021
Next Scheduled EDR Contact: 07/20/2009
Data Release Frequency: Varies
INDIAN VCP R1: Voluntary Cleanup Priority Listing
A listing of voluntary cleanup priority sites located on Indian Land located in Region 1.
Date of Government Version: 07/27/2015
Date Data Arrived at EDR: 09/29/2015
Date Made Active in Reports: 02/18/2016
Number of Days to Update: 142
Source: EPA, Region 1
Telephone: 617-918-1102
Last EDR Contact: 09/12/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Varies
VCP: Voluntary Cleanup Program Properties
Contains low threat level properties with either confirmed or unconfirmed releases and the project proponents have request that DTSC oversee investigation and/or cleanup activities and have agreed to provide coverage for DTSC’s costs.
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/25/2023
Date Made Active in Reports: 10/11/2023
Number of Days to Update: 78
Source: Department of Toxic Substances Control
Telephone: 916-323-3400
Last EDR Contact: 10/24/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Quarterly
Lists of state and tribal brownfield sites
BROWNFIELDS: Considered Brownfieds Sites Listing
A listing of sites the SWRCB considers to be Brownfields since these are sites have come to them through the MOA Process.
Date of Government Version: 06/14/2023
Date Data Arrived at EDR: 06/14/2023
Date Made Active in Reports: 09/06/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: 916-323-7905
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
ADDITIONAL ENVIRONMENTAL RECORDS
Local Brownfield lists
US BROWNFIELDS: A Listing of Brownfields Sites
Brownfields are real property, the expansion, redevelopment, or reuse of which may be complicated by the presence or potential presence of a hazardous substance, pollutant, or contaminant. Cleaning up and reinvesting in these properties takes development pressures off of undeveloped, open land, and both improves and protects the environment.
Assessment, Cleanup and Redevelopment Exchange System (ACRES) stores information reported by EPA Brownfields grant recipients on brownfields properties assessed or cleaned up with grant funding as well as information on Targeted Brownfields Assessments performed by EPA Regions. A listing of ACRES Brownfield sites is obtained from Cleanups in My Community. Cleanups in My Community provides information on Brownfields properties for which information is reported back to EPA, as well as areas served by Brownfields grant programs.
Date of Government Version: 04/06/2023
Date Data Arrived at EDR: 04/13/2023
Date Made Active in Reports: 04/19/2023
Number of Days to Update: 6
Source: Environmental Protection Agency
Telephone: 202-566-2777
Last EDR Contact: 08/30/2023
Next Scheduled EDR Contact: 12/25/2023
Data Release Frequency: Semi-Annually
TC7493604.2s Page GR-13
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Local Lists of Landfill / Solid Waste Disposal Sites
WMUDS/SWAT: Waste Management Unit Database
Waste Management Unit Database System. WMUDS is used by the State Water Resources Control Board staff and the Regional Water Quality Control Boards for program tracking and inventory of waste management units. WMUDS is composed of the following databases: Facility Information, Scheduled Inspections Information, Waste Management Unit Information, SWAT Program Information, SWAT Report Summary Information, SWAT Report Summary Data, Chapter 15 (formerly Subchapter 15) Information, Chapter 15 Monitoring Parameters, TPCA Program Information, RCRA Program Information, Closure Information, and Interested Parties Information.
Date of Government Version: 04/01/2000
Date Data Arrived at EDR: 04/10/2000
Date Made Active in Reports: 05/10/2000
Number of Days to Update: 30
Source: State Water Resources Control Board
Telephone: 916-227-4448
Last EDR Contact: 10/20/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: No Update Planned
SWRCY: Recycler Database
A listing of recycling facilities in California.
Date of Government Version: 06/02/2023
Date Data Arrived at EDR: 06/02/2023
Date Made Active in Reports: 08/23/2023
Number of Days to Update: 82
Source: Department of Conservation
Telephone: 916-323-3836
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Quarterly
HAULERS: Registered Waste Tire Haulers Listing
A listing of registered waste tire haulers.
Date of Government Version: 11/16/2022
Date Data Arrived at EDR: 11/22/2022
Date Made Active in Reports: 02/13/2023
Number of Days to Update: 83
Source: Integrated Waste Management Board
Telephone: 916-341-6422
Last EDR Contact: 11/02/2023
Next Scheduled EDR Contact: 02/19/2024
Data Release Frequency: Varies
INDIAN ODI: Report on the Status of Open Dumps on Indian Lands Location of open dumps on Indian land.
Date of Government Version: 12/31/1998
Date Data Arrived at EDR: 12/03/2007
Date Made Active in Reports: 01/24/2008
Number of Days to Update: 52
Source: Environmental Protection Agency
Telephone: 703-308-8245
Last EDR Contact: 10/23/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Varies
DEBRIS REGION 9: Torres Martinez Reservation Illegal Dump Site Locations A listing of illegal dump sites location on the Torres Martinez Indian Reservation located in eastern Riverside County and northern Imperial County, California.
Date of Government Version: 01/12/2009
Date Data Arrived at EDR: 05/07/2009
Date Made Active in Reports: 09/21/2009
Number of Days to Update: 137
Source: EPA, Region 9
Telephone: 415-947-4219
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: No Update Planned
ODI: Open Dump Inventory
An open dump is defined as a disposal facility that does not comply with one or more of the Part 257 or Part 258 Subtitle D Criteria.
Date of Government Version: 06/30/1985
Date Data Arrived at EDR: 08/09/2004
Date Made Active in Reports: 09/17/2004
Number of Days to Update: 39
Source: Environmental Protection Agency
Telephone: 800-424-9346
Last EDR Contact: 06/09/2004
Next Scheduled EDR Contact: N/A
Data Release Frequency: No Update Planned
TC7493604.2s Page GR-14
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
IHS OPEN DUMPS: Open Dumps on Indian Land
A listing of all open dumps located on Indian Land in the United States.
Date of Government Version: 04/01/2014
Date Data Arrived at EDR: 08/06/2014
Date Made Active in Reports: 01/29/2015
Number of Days to Update: 176
Source: Department of Health & Human Serivces, Indian Health Service Telephone: 301-443-1452
Last EDR Contact: 10/28/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Varies
Local Lists of Hazardous waste / Contaminated Sites
US HIST CDL: National Clandestine Laboratory Register
A listing of clandestine drug lab locations that have been removed from the DEAs National Clandestine Laboratory Register.
Date of Government Version: 08/21/2023
Date Data Arrived at EDR: 08/21/2023
Date Made Active in Reports: 11/07/2023
Number of Days to Update: 78
Source: Drug Enforcement Administration
Telephone: 202-307-1000
Last EDR Contact: 08/21/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: No Update Planned
HIST CAL-SITES: Calsites Database
The Calsites database contains potential or confirmed hazardous substance release properties. In 1996, California EPA reevaluated and significantly reduced the number of sites in the Calsites database. No longer updated by the state agency. It has been replaced by ENVIROSTOR.
Date of Government Version: 08/08/2005
Date Data Arrived at EDR: 08/03/2006
Date Made Active in Reports: 08/24/2006
Number of Days to Update: 21
Source: Department of Toxic Substance Control
Telephone: 916-323-3400
Last EDR Contact: 02/23/2009
Next Scheduled EDR Contact: 05/25/2009
Data Release Frequency: No Update Planned
SCH: School Property Evaluation Program
This category contains proposed and existing school sites that are being evaluated by DTSC for possible hazardous materials contamination. In some cases, these properties may be listed in the CalSites category depending on the level of threat to public health and safety or the environment they pose.
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/25/2023
Date Made Active in Reports: 10/11/2023
Number of Days to Update: 78
Source: Department of Toxic Substances Control
Telephone: 916-323-3400
Last EDR Contact: 10/24/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Quarterly
CDL: Clandestine Drug Labs
A listing of drug lab locations. Listing of a location in this database does not indicate that any illegal drug lab materials were or were not present there, and does not constitute a determination that the location either requires or does not require additional cleanup work.
Date of Government Version: 12/31/2020
Date Data Arrived at EDR: 11/30/2022
Date Made Active in Reports: 02/09/2023
Number of Days to Update: 71
Source: Department of Toxic Substances Control
Telephone: 916-255-6504
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
TOXIC PITS: Toxic Pits Cleanup Act Sites
Toxic PITS Cleanup Act Sites. TOXIC PITS identifies sites suspected of containing hazardous substances where cleanup has not yet been completed.
Date of Government Version: 07/01/1995
Date Data Arrived at EDR: 08/30/1995
Date Made Active in Reports: 09/26/1995
Number of Days to Update: 27
Source: State Water Resources Control Board
Telephone: 916-227-4364
Last EDR Contact: 01/26/2009
Next Scheduled EDR Contact: 04/27/2009
Data Release Frequency: No Update Planned
TC7493604.2s Page GR-15
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
CERS HAZ WASTE: California Environmental Reporting System Hazardous Waste List of sites in the California Environmental Protection Agency (CalEPA) Regulated Site Portal which fall under the Hazardous Chemical Management, Hazardous Waste Onsite Treatment, Household Hazardous Waste Collection, Hazardous Waste Generator, and RCRA LQ HW Generator programs.
Date of Government Version: 07/17/2023
Date Data Arrived at EDR: 07/18/2023
Date Made Active in Reports: 10/06/2023
Number of Days to Update: 80
Source: CalEPA
Telephone: 916-323-2514
Last EDR Contact: 10/17/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Quarterly
US CDL: Clandestine Drug Labs
A listing of clandestine drug lab locations. The U.S. Department of Justice ("the Department") provides this web site as a public service. It contains addresses of some locations where law enforcement agencies reported they found chemicals or other items that indicated the presence of either clandestine drug laboratories or dumpsites.
In most cases, the source of the entries is not the Department, and the Department has not verified the entry and does not guarantee its accuracy. Members of the public must verify the accuracy of all entries by, for example, contacting local law enforcement and local health departments.
Date of Government Version: 08/21/2023
Date Data Arrived at EDR: 08/21/2023
Date Made Active in Reports: 11/07/2023
Number of Days to Update: 78
Source: Drug Enforcement Administration
Telephone: 202-307-1000
Last EDR Contact: 08/21/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Quarterly
Local Lists of Registered Storage Tanks
SWEEPS UST: SWEEPS UST Listing
Statewide Environmental Evaluation and Planning System. This underground storage tank listing was updated and maintained by a company contacted by the SWRCB in the early 1990’s. The listing is no longer updated or maintained.
The local agency is the contact for more information on a site on the SWEEPS list.
Date of Government Version: 06/01/1994
Date Data Arrived at EDR: 07/07/2005
Date Made Active in Reports: 08/11/2005
Number of Days to Update: 35
Source: State Water Resources Control Board
Telephone: N/A
Last EDR Contact: 06/03/2005
Next Scheduled EDR Contact: N/A
Data Release Frequency: No Update Planned
HIST UST: Hazardous Substance Storage Container Database The Hazardous Substance Storage Container Database is a historical listing of UST sites. Refer to local/county source for current data.
Date of Government Version: 10/15/1990
Date Data Arrived at EDR: 01/25/1991
Date Made Active in Reports: 02/12/1991
Number of Days to Update: 18
Source: State Water Resources Control Board
Telephone: 916-341-5851
Last EDR Contact: 07/26/2001
Next Scheduled EDR Contact: N/A
Data Release Frequency: No Update Planned
SAN FRANCISCO AST: Aboveground Storage Tank Site Listing Aboveground storage tank sites
Date of Government Version: 08/04/2023
Date Data Arrived at EDR: 08/08/2023
Date Made Active in Reports: 10/25/2023
Number of Days to Update: 78
Source: San Francisco County Department of Public Health Telephone: 415-252-3896
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
CA FID UST: Facility Inventory Database
The Facility Inventory Database (FID) contains a historical listing of active and inactive underground storage tank locations from the State Water Resource Control Board. Refer to local/county source for current data.
TC7493604.2s Page GR-16
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 10/31/1994
Date Data Arrived at EDR: 09/05/1995
Date Made Active in Reports: 09/29/1995
Number of Days to Update: 24
Source: California Environmental Protection Agency
Telephone: 916-341-5851
Last EDR Contact: 12/28/1998
Next Scheduled EDR Contact: N/A
Data Release Frequency: No Update Planned
CERS TANKS: California Environmental Reporting System (CERS) Tanks List of sites in the California Environmental Protection Agency (CalEPA) Regulated Site Portal which fall under the Aboveground Petroleum Storage and Underground Storage Tank regulatory programs.
Date of Government Version: 07/17/2023
Date Data Arrived at EDR: 07/18/2023
Date Made Active in Reports: 10/06/2023
Number of Days to Update: 80
Source: California Environmental Protection Agency
Telephone: 916-323-2514
Last EDR Contact: 10/17/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Quarterly
Local Land Records
LIENS: Environmental Liens Listing
A listing of property locations with environmental liens for California where DTSC is a lien holder.
Date of Government Version: 08/22/2023
Date Data Arrived at EDR: 08/24/2023
Date Made Active in Reports: 11/07/2023
Number of Days to Update: 75
Source: Department of Toxic Substances Control
Telephone: 916-323-3400
Last EDR Contact: 08/22/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Varies
LIENS 2: CERCLA Lien Information
A Federal CERCLA (’Superfund’) lien can exist by operation of law at any site or property at which EPA has spent Superfund monies. These monies are spent to investigate and address releases and threatened releases of contamination.
CERCLIS provides information as to the identity of these sites and properties.
Date of Government Version: 09/19/2023
Date Data Arrived at EDR: 10/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 16
Source: Environmental Protection Agency
Telephone: 202-564-6023
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Semi-Annually
DEED: Deed Restriction Listing
Site Mitigation and Brownfields Reuse Program Facility Sites with Deed Restrictions & Hazardous Waste Management Program Facility Sites with Deed / Land Use Restriction. The DTSC Site Mitigation and Brownfields Reuse Program (SMBRP) list includes sites cleaned up under the program’s oversight and generally does not include current or former hazardous waste facilities that required a hazardous waste facility permit. The list represents deed restrictions that are active. Some sites have multiple deed restrictions. The DTSC Hazardous Waste Management Program (HWMP) has developed a list of current or former hazardous waste facilities that have a recorded land use restriction at the local county recorder’s office. The land use restrictions on this list were required by the DTSC HWMP as a result of the presence of hazardous substances that remain on site after the facility (or part of the facility) has been closed or cleaned up. The types of land use restriction include deed notice, deed restriction, or a land use restriction that binds current and future owners.
Date of Government Version: 05/25/2023
Date Data Arrived at EDR: 05/25/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 81
Source: DTSC and SWRCB
Telephone: 916-323-3400
Last EDR Contact: 08/29/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Semi-Annually
Records of Emergency Release Reports
TC7493604.2s Page GR-17
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
HMIRS: Hazardous Materials Information Reporting System Hazardous Materials Incident Report System. HMIRS contains hazardous material spill incidents reported to DOT.
Date of Government Version: 06/19/2023
Date Data Arrived at EDR: 06/23/2023
Date Made Active in Reports: 09/20/2023
Number of Days to Update: 89
Source: U.S. Department of Transportation
Telephone: 202-366-4555
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
CHMIRS: California Hazardous Material Incident Report System California Hazardous Material Incident Reporting System. CHMIRS contains information on reported hazardous material incidents (accidental releases or spills).
Date of Government Version: 06/01/2023
Date Data Arrived at EDR: 07/18/2023
Date Made Active in Reports: 10/05/2023
Number of Days to Update: 79
Source: Office of Emergency Services
Telephone: 916-845-8400
Last EDR Contact: 10/20/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Semi-Annually
LDS: Land Disposal Sites Listing (GEOTRACKER)
Land Disposal sites (Landfills) included in GeoTracker. GeoTracker is the Water Boards data management system for sites that impact, or have the potential to impact, water quality in California, with emphasis on groundwater.
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/25/2023
Number of Days to Update: 81
Source: State Water Qualilty Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Quarterly
MCS: Military Cleanup Sites Listing (GEOTRACKER)
Military sites (consisting of: Military UST sites; Military Privatized sites; and Military Cleanup sites [formerly known as DoD non UST]) included in GeoTracker. GeoTracker is the Water Boards data management system for sites that impact, or have the potential to impact, water quality in California, with emphasis on groundwater.
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/25/2023
Number of Days to Update: 81
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Quarterly
SPILLS 90: SPILLS90 data from FirstSearch
Spills 90 includes those spill and release records available exclusively from FirstSearch databases. Typically, they may include chemical, oil and/or hazardous substance spills recorded after 1990. Duplicate records that are already included in EDR incident and release records are not included in Spills 90.
Date of Government Version: 06/06/2012
Date Data Arrived at EDR: 01/03/2013
Date Made Active in Reports: 02/22/2013
Number of Days to Update: 50
Source: FirstSearch
Telephone: N/A
Last EDR Contact: 01/03/2013
Next Scheduled EDR Contact: N/A
Data Release Frequency: No Update Planned
Other Ascertainable Records
RCRA NonGen / NLR: RCRA - Non Generators / No Longer Regulated RCRAInfo is EPA’s comprehensive information system, providing access to data supporting the Resource Conservation and Recovery Act (RCRA) of 1976 and the Hazardous and Solid Waste Amendments (HSWA) of 1984. The database includes selective information on sites which generate, transport, store, treat and/or dispose of hazardous waste as defined by the Resource Conservation and Recovery Act (RCRA). Non-Generators do not presently generate hazardous waste.
TC7493604.2s Page GR-18
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/31/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 14
Source: Environmental Protection Agency
Telephone: (415) 495-8895
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
FUDS: Formerly Used Defense Sites
The listing includes locations of Formerly Used Defense Sites properties where the US Army Corps of Engineers is actively working or will take necessary cleanup actions.
Date of Government Version: 08/07/2023
Date Data Arrived at EDR: 08/15/2023
Date Made Active in Reports: 10/10/2023
Number of Days to Update: 56
Source: U.S. Army Corps of Engineers
Telephone: 202-528-4285
Last EDR Contact: 08/15/2023
Next Scheduled EDR Contact: 11/27/2023
Data Release Frequency: Varies
DOD: Department of Defense Sites
This data set consists of federally owned or administered lands, administered by the Department of Defense, that have any area equal to or greater than 640 acres of the United States, Puerto Rico, and the U.S. Virgin Islands.
Date of Government Version: 06/07/2021
Date Data Arrived at EDR: 07/13/2021
Date Made Active in Reports: 03/09/2022
Number of Days to Update: 239
Source: USGS
Telephone: 888-275-8747
Last EDR Contact: 10/09/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: Varies
FEDLAND: Federal and Indian Lands
Federally and Indian administrated lands of the United States. Lands included are administrated by: Army Corps of Engineers, Bureau of Reclamation, National Wild and Scenic River, National Wildlife Refuge, Public Domain Land, Wilderness, Wilderness Study Area, Wildlife Management Area, Bureau of Indian Affairs, Bureau of Land Management, Department of Justice, Forest Service, Fish and Wildlife Service, National Park Service.
Date of Government Version: 04/02/2018
Date Data Arrived at EDR: 04/11/2018
Date Made Active in Reports: 11/06/2019
Number of Days to Update: 574
Source: U.S. Geological Survey
Telephone: 888-275-8747
Last EDR Contact: 10/04/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: N/A
SCRD DRYCLEANERS: State Coalition for Remediation of Drycleaners Listing The State Coalition for Remediation of Drycleaners was established in 1998, with support from the U.S. EPA Office of Superfund Remediation and Technology Innovation. It is comprised of representatives of states with established drycleaner remediation programs. Currently the member states are Alabama, Connecticut, Florida, Illinois, Kansas, Minnesota, Missouri, North Carolina, Oregon, South Carolina, Tennessee, Texas, and Wisconsin.
Date of Government Version: 07/30/2021
Date Data Arrived at EDR: 02/03/2023
Date Made Active in Reports: 02/10/2023
Number of Days to Update: 7
Source: Environmental Protection Agency
Telephone: 615-532-8599
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/19/2024
Data Release Frequency: Varies
US FIN ASSUR: Financial Assurance Information
All owners and operators of facilities that treat, store, or dispose of hazardous waste are required to provide proof that they will have sufficient funds to pay for the clean up, closure, and post-closure care of their facilities.
Date of Government Version: 06/19/2023
Date Data Arrived at EDR: 06/20/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 55
Source: Environmental Protection Agency
Telephone: 202-566-1917
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
TC7493604.2s Page GR-19
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
EPA WATCH LIST: EPA WATCH LIST
EPA maintains a "Watch List" to facilitate dialogue between EPA, state and local environmental agencies on enforcement matters relating to facilities with alleged violations identified as either significant or high priority. Being on the Watch List does not mean that the facility has actually violated the law only that an investigation by EPA or a state or local environmental agency has led those organizations to allege that an unproven violation has in fact occurred. Being on the Watch List does not represent a higher level of concern regarding the alleged violations that were detected, but instead indicates cases requiring additional dialogue between EPA, state and local agencies - primarily because of the length of time the alleged violation has gone unaddressed or unresolved.
Date of Government Version: 08/30/2013
Date Data Arrived at EDR: 03/21/2014
Date Made Active in Reports: 06/17/2014
Number of Days to Update: 88
Source: Environmental Protection Agency
Telephone: 617-520-3000
Last EDR Contact: 10/31/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Quarterly
2020 COR ACTION: 2020 Corrective Action Program List
The EPA has set ambitious goals for the RCRA Corrective Action program by creating the 2020 Corrective Action Universe. This RCRA cleanup baseline includes facilities expected to need corrective action. The 2020 universe contains a wide variety of sites. Some properties are heavily contaminated while others were contaminated but have since been cleaned up. Still others have not been fully investigated yet, and may require little or no remediation.
Inclusion in the 2020 Universe does not necessarily imply failure on the part of a facility to meet its RCRA obligations.
Date of Government Version: 09/30/2017
Date Data Arrived at EDR: 05/08/2018
Date Made Active in Reports: 07/20/2018
Number of Days to Update: 73
Source: Environmental Protection Agency
Telephone: 703-308-4044
Last EDR Contact: 11/03/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
TSCA: Toxic Substances Control Act
Toxic Substances Control Act. TSCA identifies manufacturers and importers of chemical substances included on the TSCA Chemical Substance Inventory list. It includes data on the production volume of these substances by plant site.
Date of Government Version: 12/31/2020
Date Data Arrived at EDR: 06/14/2022
Date Made Active in Reports: 03/24/2023
Number of Days to Update: 283
Source: EPA
Telephone: 202-260-5521
Last EDR Contact: 09/15/2023
Next Scheduled EDR Contact: 12/25/2023
Data Release Frequency: Every 4 Years
TRIS: Toxic Chemical Release Inventory System
Toxic Release Inventory System. TRIS identifies facilities which release toxic chemicals to the air, water and land in reportable quantities under SARA Title III Section 313.
Date of Government Version: 12/31/2021
Date Data Arrived at EDR: 08/18/2023
Date Made Active in Reports: 11/07/2023
Number of Days to Update: 81
Source: EPA
Telephone: 202-566-0250
Last EDR Contact: 08/18/2023
Next Scheduled EDR Contact: 11/27/2023
Data Release Frequency: Annually
SSTS: Section 7 Tracking Systems
Section 7 of the Federal Insecticide, Fungicide and Rodenticide Act, as amended (92 Stat. 829) requires all registered pesticide-producing establishments to submit a report to the Environmental Protection Agency by March 1st each year. Each establishment must report the types and amounts of pesticides, active ingredients and devices being produced, and those having been produced and sold or distributed in the past year.
Date of Government Version: 07/17/2023
Date Data Arrived at EDR: 07/18/2023
Date Made Active in Reports: 10/10/2023
Number of Days to Update: 84
Source: EPA
Telephone: 202-564-4203
Last EDR Contact: 10/20/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Annually
TC7493604.2s Page GR-20
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
ROD: Records Of Decision
Record of Decision. ROD documents mandate a permanent remedy at an NPL (Superfund) site containing technical and health information to aid in the cleanup.
Date of Government Version: 09/19/2023
Date Data Arrived at EDR: 10/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 16
Source: EPA
Telephone: 703-416-0223
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Annually
RMP: Risk Management Plans
When Congress passed the Clean Air Act Amendments of 1990, it required EPA to publish regulations and guidance for chemical accident prevention at facilities using extremely hazardous substances. The Risk Management Program Rule (RMP Rule) was written to implement Section 112(r) of these amendments. The rule, which built upon existing industry codes and standards, requires companies of all sizes that use certain flammable and toxic substances to develop a Risk Management Program, which includes a(n): Hazard assessment that details the potential effects of an accidental release, an accident history of the last five years, and an evaluation of worst-case and alternative accidental releases; Prevention program that includes safety precautions and maintenance, monitoring, and employee training measures; and Emergency response program that spells out emergency health care, employee training measures and procedures for informing the public and response agencies (e.g the fire department) should an accident occur.
Date of Government Version: 05/09/2023
Date Data Arrived at EDR: 06/29/2023
Date Made Active in Reports: 09/25/2023
Number of Days to Update: 88
Source: Environmental Protection Agency
Telephone: 202-564-8600
Last EDR Contact: 09/26/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
RAATS: RCRA Administrative Action Tracking System
RCRA Administration Action Tracking System. RAATS contains records based on enforcement actions issued under RCRA pertaining to major violators and includes administrative and civil actions brought by the EPA. For administration actions after September 30, 1995, data entry in the RAATS database was discontinued. EPA will retain a copy of the database for historical records. It was necessary to terminate RAATS because a decrease in agency resources made it impossible to continue to update the information contained in the database.
Date of Government Version: 04/17/1995
Date Data Arrived at EDR: 07/03/1995
Date Made Active in Reports: 08/07/1995
Number of Days to Update: 35
Source: EPA
Telephone: 202-564-4104
Last EDR Contact: 06/02/2008
Next Scheduled EDR Contact: 09/01/2008
Data Release Frequency: No Update Planned
PRP: Potentially Responsible Parties
A listing of verified Potentially Responsible Parties
Date of Government Version: 09/19/2023
Date Data Arrived at EDR: 10/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 16
Source: EPA
Telephone: 202-564-6023
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Quarterly
PADS: PCB Activity Database System
PCB Activity Database. PADS Identifies generators, transporters, commercial storers and/or brokers and disposers of PCB’s who are required to notify the EPA of such activities.
Date of Government Version: 03/20/2023
Date Data Arrived at EDR: 04/04/2023
Date Made Active in Reports: 06/09/2023
Number of Days to Update: 66
Source: EPA
Telephone: 202-566-0500
Last EDR Contact: 10/06/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Annually
TC7493604.2s Page GR-21
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
ICIS: Integrated Compliance Information System
The Integrated Compliance Information System (ICIS) supports the information needs of the national enforcement and compliance program as well as the unique needs of the National Pollutant Discharge Elimination System (NPDES) program.
Date of Government Version: 11/18/2016
Date Data Arrived at EDR: 11/23/2016
Date Made Active in Reports: 02/10/2017
Number of Days to Update: 79
Source: Environmental Protection Agency
Telephone: 202-564-2501
Last EDR Contact: 09/27/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Quarterly
FTTS: FIFRA/ TSCA Tracking System - FIFRA (Federal Insecticide, Fungicide, & Rodenticide Act)/TSCA (Toxic Substances Control Act) FTTS tracks administrative cases and pesticide enforcement actions and compliance activities related to FIFRA, TSCA and EPCRA (Emergency Planning and Community Right-to-Know Act). To maintain currency, EDR contacts the Agency on a quarterly basis.
Date of Government Version: 04/09/2009
Date Data Arrived at EDR: 04/16/2009
Date Made Active in Reports: 05/11/2009
Number of Days to Update: 25
Source: EPA/Office of Prevention, Pesticides and Toxic Substances Telephone: 202-566-1667
Last EDR Contact: 08/18/2017
Next Scheduled EDR Contact: 12/04/2017
Data Release Frequency: No Update Planned
FTTS INSP: FIFRA/ TSCA Tracking System - FIFRA (Federal Insecticide, Fungicide, & Rodenticide Act)/TSCA (Toxic Substances Control Act) A listing of FIFRA/TSCA Tracking System (FTTS) inspections and enforcements.
Date of Government Version: 04/09/2009
Date Data Arrived at EDR: 04/16/2009
Date Made Active in Reports: 05/11/2009
Number of Days to Update: 25
Source: EPA
Telephone: 202-566-1667
Last EDR Contact: 08/18/2017
Next Scheduled EDR Contact: 12/04/2017
Data Release Frequency: No Update Planned
MLTS: Material Licensing Tracking System
MLTS is maintained by the Nuclear Regulatory Commission and contains a list of approximately 8,100 sites which possess or use radioactive materials and which are subject to NRC licensing requirements. To maintain currency, EDR contacts the Agency on a quarterly basis.
Date of Government Version: 07/20/2023
Date Data Arrived at EDR: 09/01/2023
Date Made Active in Reports: 09/20/2023
Number of Days to Update: 19
Source: Nuclear Regulatory Commission
Telephone: 301-415-0717
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Quarterly
COAL ASH DOE: Steam-Electric Plant Operation Data
A listing of power plants that store ash in surface ponds.
Date of Government Version: 12/31/2021
Date Data Arrived at EDR: 04/14/2023
Date Made Active in Reports: 07/10/2023
Number of Days to Update: 87
Source: Department of Energy
Telephone: 202-586-8719
Last EDR Contact: 09/01/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Varies
COAL ASH EPA: Coal Combustion Residues Surface Impoundments List A listing of coal combustion residues surface impoundments with high hazard potential ratings.
Date of Government Version: 01/12/2017
Date Data Arrived at EDR: 03/05/2019
Date Made Active in Reports: 11/11/2019
Number of Days to Update: 251
Source: Environmental Protection Agency
Telephone: N/A
Last EDR Contact: 08/28/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Varies
TC7493604.2s Page GR-22
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
PCB TRANSFORMER: PCB Transformer Registration Database
The database of PCB transformer registrations that includes all PCB registration submittals.
Date of Government Version: 09/13/2019
Date Data Arrived at EDR: 11/06/2019
Date Made Active in Reports: 02/10/2020
Number of Days to Update: 96
Source: Environmental Protection Agency
Telephone: 202-566-0517
Last EDR Contact: 11/03/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
RADINFO: Radiation Information Database
The Radiation Information Database (RADINFO) contains information about facilities that are regulated by U.S.
Environmental Protection Agency (EPA) regulations for radiation and radioactivity.
Date of Government Version: 07/01/2019
Date Data Arrived at EDR: 07/01/2019
Date Made Active in Reports: 09/23/2019
Number of Days to Update: 84
Source: Environmental Protection Agency
Telephone: 202-343-9775
Last EDR Contact: 09/22/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Quarterly
HIST FTTS: FIFRA/TSCA Tracking System Administrative Case Listing A complete administrative case listing from the FIFRA/TSCA Tracking System (FTTS) for all ten EPA regions. The information was obtained from the National Compliance Database (NCDB). NCDB supports the implementation of FIFRA (Federal Insecticide, Fungicide, and Rodenticide Act) and TSCA (Toxic Substances Control Act). Some EPA regions are now closing out records. Because of that, and the fact that some EPA regions are not providing EPA Headquarters with updated records, it was decided to create a HIST FTTS database. It included records that may not be included in the newer FTTS database updates. This database is no longer updated.
Date of Government Version: 10/19/2006
Date Data Arrived at EDR: 03/01/2007
Date Made Active in Reports: 04/10/2007
Number of Days to Update: 40
Source: Environmental Protection Agency
Telephone: 202-564-2501
Last EDR Contact: 12/17/2007
Next Scheduled EDR Contact: 03/17/2008
Data Release Frequency: No Update Planned
HIST FTTS INSP: FIFRA/TSCA Tracking System Inspection & Enforcement Case Listing A complete inspection and enforcement case listing from the FIFRA/TSCA Tracking System (FTTS) for all ten EPA regions. The information was obtained from the National Compliance Database (NCDB). NCDB supports the implementation of FIFRA (Federal Insecticide, Fungicide, and Rodenticide Act) and TSCA (Toxic Substances Control Act). Some EPA regions are now closing out records. Because of that, and the fact that some EPA regions are not providing EPA Headquarters with updated records, it was decided to create a HIST FTTS database. It included records that may not be included in the newer FTTS database updates. This database is no longer updated.
Date of Government Version: 10/19/2006
Date Data Arrived at EDR: 03/01/2007
Date Made Active in Reports: 04/10/2007
Number of Days to Update: 40
Source: Environmental Protection Agency
Telephone: 202-564-2501
Last EDR Contact: 12/17/2008
Next Scheduled EDR Contact: 03/17/2008
Data Release Frequency: No Update Planned
DOT OPS: Incident and Accident Data
Department of Transporation, Office of Pipeline Safety Incident and Accident data.
Date of Government Version: 01/02/2020
Date Data Arrived at EDR: 01/28/2020
Date Made Active in Reports: 04/17/2020
Number of Days to Update: 80
Source: Department of Transporation, Office of Pipeline Safety Telephone: 202-366-4595
Last EDR Contact: 10/04/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Quarterly
CONSENT: Superfund (CERCLA) Consent Decrees
Major legal settlements that establish responsibility and standards for cleanup at NPL (Superfund) sites. Released periodically by United States District Courts after settlement by parties to litigation matters.
TC7493604.2s Page GR-23
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 06/30/2023
Date Data Arrived at EDR: 07/19/2023
Date Made Active in Reports: 10/10/2023
Number of Days to Update: 83
Source: Department of Justice, Consent Decree Library
Telephone: Varies
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
BRS: Biennial Reporting System
The Biennial Reporting System is a national system administered by the EPA that collects data on the generation and management of hazardous waste. BRS captures detailed data from two groups: Large Quantity Generators (LQG) and Treatment, Storage, and Disposal Facilities.
Date of Government Version: 12/31/2021
Date Data Arrived at EDR: 03/09/2023
Date Made Active in Reports: 03/20/2023
Number of Days to Update: 11
Source: EPA/NTIS
Telephone: 800-424-9346
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Biennially
INDIAN RESERV: Indian Reservations
This map layer portrays Indian administered lands of the United States that have any area equal to or greater than 640 acres.
Date of Government Version: 12/31/2014
Date Data Arrived at EDR: 07/14/2015
Date Made Active in Reports: 01/10/2017
Number of Days to Update: 546
Source: USGS
Telephone: 202-208-3710
Last EDR Contact: 10/02/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Semi-Annually
FUSRAP: Formerly Utilized Sites Remedial Action Program DOE established the Formerly Utilized Sites Remedial Action Program (FUSRAP) in 1974 to remediate sites where radioactive contamination remained from Manhattan Project and early U.S. Atomic Energy Commission (AEC) operations.
Date of Government Version: 03/03/2023
Date Data Arrived at EDR: 03/03/2023
Date Made Active in Reports: 06/09/2023
Number of Days to Update: 98
Source: Department of Energy
Telephone: 202-586-3559
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
UMTRA: Uranium Mill Tailings Sites
Uranium ore was mined by private companies for federal government use in national defense programs. When the mills shut down, large piles of the sand-like material (mill tailings) remain after uranium has been extracted from the ore. Levels of human exposure to radioactive materials from the piles are low; however, in some cases tailings were used as construction materials before the potential health hazards of the tailings were recognized.
Date of Government Version: 08/30/2019
Date Data Arrived at EDR: 11/15/2019
Date Made Active in Reports: 01/28/2020
Number of Days to Update: 74
Source: Department of Energy
Telephone: 505-845-0011
Last EDR Contact: 08/10/2023
Next Scheduled EDR Contact: 11/27/2023
Data Release Frequency: Varies
LEAD SMELTER 1: Lead Smelter Sites
A listing of former lead smelter site locations.
Date of Government Version: 09/19/2023
Date Data Arrived at EDR: 10/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 16
Source: Environmental Protection Agency
Telephone: 703-603-8787
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Varies
LEAD SMELTER 2: Lead Smelter Sites
A list of several hundred sites in the U.S. where secondary lead smelting was done from 1931and 1964. These sites may pose a threat to public health through ingestion or inhalation of contaminated soil or dust TC7493604.2s Page GR-24
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 04/05/2001
Date Data Arrived at EDR: 10/27/2010
Date Made Active in Reports: 12/02/2010
Number of Days to Update: 36
Source: American Journal of Public Health
Telephone: 703-305-6451
Last EDR Contact: 12/02/2009
Next Scheduled EDR Contact: N/A
Data Release Frequency: No Update Planned
US AIRS (AFS): Aerometric Information Retrieval System Facility Subsystem (AFS) The database is a sub-system of Aerometric Information Retrieval System (AIRS). AFS contains compliance data on air pollution point sources regulated by the U.S. EPA and/or state and local air regulatory agencies. This information comes from source reports by various stationary sources of air pollution, such as electric power plants, steel mills, factories, and universities, and provides information about the air pollutants they produce. Action, air program, air program pollutant, and general level plant data. It is used to track emissions and compliance data from industrial plants.
Date of Government Version: 10/12/2016
Date Data Arrived at EDR: 10/26/2016
Date Made Active in Reports: 02/03/2017
Number of Days to Update: 100
Source: EPA
Telephone: 202-564-2496
Last EDR Contact: 09/26/2017
Next Scheduled EDR Contact: 01/08/2018
Data Release Frequency: Annually
US AIRS MINOR: Air Facility System Data
A listing of minor source facilities.
Date of Government Version: 10/12/2016
Date Data Arrived at EDR: 10/26/2016
Date Made Active in Reports: 02/03/2017
Number of Days to Update: 100
Source: EPA
Telephone: 202-564-2496
Last EDR Contact: 09/26/2017
Next Scheduled EDR Contact: 01/08/2018
Data Release Frequency: Annually
MINES VIOLATIONS: MSHA Violation Assessment Data
Mines violation and assessment information. Department of Labor, Mine Safety & Health Administration.
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/05/2023
Date Made Active in Reports: 09/25/2023
Number of Days to Update: 82
Source: DOL, Mine Safety & Health Admi
Telephone: 202-693-9424
Last EDR Contact: 10/04/2023
Next Scheduled EDR Contact: 02/19/2024
Data Release Frequency: Quarterly
US MINES: Mines Master Index File
Contains all mine identification numbers issued for mines active or opened since 1971. The data also includes violation information.
Date of Government Version: 08/01/2023
Date Data Arrived at EDR: 08/22/2023
Date Made Active in Reports: 11/07/2023
Number of Days to Update: 77
Source: Department of Labor, Mine Safety and Health Administration Telephone: 303-231-5959
Last EDR Contact: 08/22/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Semi-Annually
US MINES 2: Ferrous and Nonferrous Metal Mines Database Listing This map layer includes ferrous (ferrous metal mines are facilities that extract ferrous metals, such as iron ore or molybdenum) and nonferrous (Nonferrous metal mines are facilities that extract nonferrous metals, such as gold, silver, copper, zinc, and lead) metal mines in the United States.
Date of Government Version: 01/07/2022
Date Data Arrived at EDR: 02/24/2023
Date Made Active in Reports: 05/17/2023
Number of Days to Update: 82
Source: USGS
Telephone: 703-648-7709
Last EDR Contact: 08/24/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Varies
TC7493604.2s Page GR-25
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
US MINES 3: Active Mines & Mineral Plants Database Listing Active Mines and Mineral Processing Plant operations for commodities monitored by the Minerals Information Team of the USGS.
Date of Government Version: 04/14/2011
Date Data Arrived at EDR: 06/08/2011
Date Made Active in Reports: 09/13/2011
Number of Days to Update: 97
Source: USGS
Telephone: 703-648-7709
Last EDR Contact: 08/24/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Varies
MINES MRDS: Mineral Resources Data System
Mineral Resources Data System
Date of Government Version: 08/23/2022
Date Data Arrived at EDR: 11/22/2022
Date Made Active in Reports: 02/28/2023
Number of Days to Update: 98
Source: USGS
Telephone: 703-648-6533
Last EDR Contact: 08/24/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Varies
ABANDONED MINES: Abandoned Mines
An inventory of land and water impacted by past mining (primarily coal mining) is maintained by OSMRE to provide information needed to implement the Surface Mining Control and Reclamation Act of 1977 (SMCRA). The inventory contains information on the location, type, and extent of AML impacts, as well as, information on the cost associated with the reclamation of those problems. The inventory is based upon field surveys by State, Tribal, and OSMRE program officials. It is dynamic to the extent that it is modified as new problems are identified and existing problems are reclaimed.
Date of Government Version: 06/13/2023
Date Data Arrived at EDR: 06/14/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 61
Source: Department of Interior
Telephone: 202-208-2609
Last EDR Contact: 09/12/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Quarterly
FINDS: Facility Index System/Facility Registry System
Facility Index System. FINDS contains both facility information and ’pointers’ to other sources that contain more detail. EDR includes the following FINDS databases in this report: PCS (Permit Compliance System), AIRS (Aerometric Information Retrieval System), DOCKET (Enforcement Docket used to manage and track information on civil judicial enforcement cases for all environmental statutes), FURS (Federal Underground Injection Control), C-DOCKET (Criminal Docket System used to track criminal enforcement actions for all environmental statutes), FFIS (Federal Facilities Information System), STATE (State Environmental Laws and Statutes), and PADS (PCB Activity Data System).
Date of Government Version: 05/04/2023
Date Data Arrived at EDR: 05/25/2023
Date Made Active in Reports: 07/24/2023
Number of Days to Update: 60
Source: EPA
Telephone: (415) 947-8000
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Quarterly
ECHO: Enforcement & Compliance History Information
ECHO provides integrated compliance and enforcement information for about 800,000 regulated facilities nationwide.
Date of Government Version: 06/24/2023
Date Data Arrived at EDR: 06/29/2023
Date Made Active in Reports: 09/25/2023
Number of Days to Update: 88
Source: Environmental Protection Agency
Telephone: 202-564-2280
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Quarterly
UXO: Unexploded Ordnance Sites
A listing of unexploded ordnance site locations
TC7493604.2s Page GR-26
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 11/09/2021
Date Data Arrived at EDR: 10/20/2022
Date Made Active in Reports: 01/10/2023
Number of Days to Update: 82
Source: Department of Defense
Telephone: 703-704-1564
Last EDR Contact: 09/13/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: Varies
DOCKET HWC: Hazardous Waste Compliance Docket Listing
A complete list of the Federal Agency Hazardous Waste Compliance Docket Facilities.
Date of Government Version: 05/06/2021
Date Data Arrived at EDR: 05/21/2021
Date Made Active in Reports: 08/11/2021
Number of Days to Update: 82
Source: Environmental Protection Agency
Telephone: 202-564-0527
Last EDR Contact: 08/15/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Varies
FUELS PROGRAM: EPA Fuels Program Registered Listing
This listing includes facilities that are registered under the Part 80 (Code of Federal Regulations) EPA Fuels Programs. All companies now are required to submit new and updated registrations.
Date of Government Version: 08/14/2023
Date Data Arrived at EDR: 08/15/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 65
Source: EPA
Telephone: 800-385-6164
Last EDR Contact: 08/15/2023
Next Scheduled EDR Contact: 11/27/2023
Data Release Frequency: Quarterly
PFAS NPL: Superfund Sites with PFAS Detections Information EPA’s Office of Land and Emergency Management and EPA Regional Offices maintain data describing what is known about site investigations, contamination, and remedial actions under the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) where PFAS is present in the environment.
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/05/2023
Date Made Active in Reports: 10/02/2023
Number of Days to Update: 89
Source: Environmental Protection Agency
Telephone: 703-603-8895
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
PFAS FEDERAL SITES: Federal Sites PFAS Information
Several federal entities, such as the federal Superfund program, Department of Defense, National Aeronautics and Space Administration, Department of Transportation, and Department of Energy provided information for sites with known or suspected detections at federal facilities.
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/05/2023
Date Made Active in Reports: 10/02/2023
Number of Days to Update: 89
Source: Environmental Protection Agency
Telephone: 202-272-0167
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
PFAS TRIS: List of PFAS Added to the TRI
Section 7321 of the National Defense Authorization Act for Fiscal Year 2020 (NDAA) immediately added certain per- and polyfluoroalkyl substances (PFAS) to the list of chemicals covered by the Toxics Release Inventory (TRI) under Section 313 of the Emergency Planning and Community Right-to-Know Act (EPCRA) and provided a framework for additional PFAS to be added to TRI on an annual basis.
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/05/2023
Date Made Active in Reports: 10/02/2023
Number of Days to Update: 89
Source: Environmental Protection Agency
Telephone: 202-566-0250
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
TC7493604.2s Page GR-27
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
PFAS TSCA: PFAS Manufacture and Imports Information
EPA issued the Chemical Data Reporting (CDR) Rule under the Toxic Substances Control Act (TSCA) and requires chemical manufacturers and facilities that manufacture or import chemical substances to report data to EPA. EPA publishes non-confidential business information (non-CBI) and includes descriptive information about each site, corporate parent, production volume, other manufacturing information, and processing and use information.
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/05/2023
Date Made Active in Reports: 10/02/2023
Number of Days to Update: 89
Source: Environmental Protection Agency
Telephone: 202-272-0167
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
PFAS RCRA MANIFEST: PFAS Transfers Identified In the RCRA Database Listing To work around the lack of PFAS waste codes in the RCRA database, EPA developed the PFAS Transfers dataset by mining e-Manifest records containing at least one of these common PFAS keywords: PFAS, PFOA, PFOS, PERFL, AFFF, GENX, GEN-X (plus the VT waste codes). These keywords were searched for in the following text fields: Manifest handling instructions (MANIFEST_HANDLING_INSTR), Non-hazardous waste description (NON_HAZ_WASTE_DESCRIPTION), DOT printed information (DOT_PRINTED_INFORMATION), Waste line handling instructions (WASTE_LINE_HANDLING_INSTR), Waste residue comments (WASTE_RESIDUE_COMMENTS).
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/05/2023
Date Made Active in Reports: 10/02/2023
Number of Days to Update: 89
Source: Environmental Protection Agency
Telephone: 202-272-0167
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
PFAS ATSDR: PFAS Contamination Site Location Listing
PFAS contamination site locations from the Department of Health & Human Services, Center for Disease Control & Prevention. ATSDR is involved at a number of PFAS-related sites, either directly or through assisting state and federal partners. As of now, most sites are related to drinking water contamination connected with PFAS production facilities or fire training areas where aqueous film-forming firefighting foam (AFFF) was regularly used.
Date of Government Version: 06/24/2020
Date Data Arrived at EDR: 03/17/2021
Date Made Active in Reports: 11/08/2022
Number of Days to Update: 601
Source: Department of Health & Human Services
Telephone: 202-741-5770
Last EDR Contact: 10/23/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Varies
PFAS WQP: Ambient Environmental Sampling for PFAS
The Water Quality Portal (WQP) is a part of a modernized repository storing ambient sampling data for all environmental media and tissue samples. A wide range of federal, state, tribal and local governments, academic and non-governmental organizations and individuals submit project details and sampling results to this public repository. The information is commonly used for research and assessments of environmental quality.
Date of Government Version: 09/23/2023
Date Data Arrived at EDR: 10/03/2023
Date Made Active in Reports: 10/10/2023
Number of Days to Update: 7
Source: Environmental Protection Agency
Telephone: 202-272-0167
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
PFAS NPDES: Clean Water Act Discharge Monitoring Information Any discharger of pollutants to waters of the United States from a point source must have a National Pollutant Discharge Elimination System (NPDES) permit. The process for obtaining limits involves the regulated entity (permittee) disclosing releases in a NPDES permit application and the permitting authority (typically the state but sometimes EPA) deciding whether to require monitoring or monitoring with limits. Caveats and Limitations:
Less than half of states have required PFAS monitoring for at least one of their permittees and fewer states have established PFAS effluent limits for permittees. New rulemakings have been initiated that may increase the number of facilities monitoring for PFAS in the future.
TC7493604.2s Page GR-28
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/05/2023
Date Made Active in Reports: 10/02/2023
Number of Days to Update: 89
Source: Environmental Protection Agency
Telephone: 202-272-0167
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
PFAS ECHO: Facilities in Industries that May Be Handling PFAS Listing Regulators and the public have expressed interest in knowing which regulated entities may be using PFAS. EPA has developed a dataset from various sources that show which industries may be handling PFAS. Approximately 120,000 facilities subject to federal environmental programs have operated or currently operate in industry sectors with processes that may involve handling and/or release of PFAS.
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/05/2023
Date Made Active in Reports: 09/25/2023
Number of Days to Update: 82
Source: Environmental Protection Agency
Telephone: 202-272-0167
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
PFAS ECHO FIRE TRAINING: Facilities in Industries that May Be Handling PFAS Listing A list of fire training sites was added to the Industry Sectors dataset using a keyword search on the permitted facilitys name to identify sites where fire-fighting foam may have been used in training exercises. Additionally, you may view an example spreadsheet of the subset of fire training facility data, as well as the keywords used in selecting or deselecting a facility for the subset. as well as the keywords used in selecting or deselecting a facility for the subset. These keywords were tested to maximize accuracy in selecting facilities that may use fire-fighting foam in training exercises, however, due to the lack of a required reporting field in the data systems for designating fire training sites, this methodology may not identify all fire training sites or may potentially misidentify them.
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/05/2023
Date Made Active in Reports: 09/25/2023
Number of Days to Update: 82
Source: Environmental Protection Agency
Telephone: 202-272-0167
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
PFAS PART 139 AIRPORT: All Certified Part 139 Airports PFAS Information Listing Since July 1, 2006, all certified part 139 airports are required to have fire-fighting foam onsite that meet military specifications (MIL-F-24385) (14 CFR 139.317). To date, these military specification fire-fighting foams are fluorinated and have been historically used for training and extinguishing. The 2018 FAA Reauthorization Act has a provision stating that no later than October 2021, FAA shall not require the use of fluorinated AFFF. This provision does not prohibit the use of fluorinated AFFF at Part 139 civilian airports; it only prohibits FAA from mandating its use. The Federal Aviation Administration?s document AC 150/5210-6D - Aircraft Fire Extinguishing Agents provides guidance on Aircraft Fire Extinguishing Agents, which includes Aqueous Film Forming Foam (AFFF).
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/05/2023
Date Made Active in Reports: 09/25/2023
Number of Days to Update: 82
Source: Environmental Protection Agency
Telephone: 202-272-0167
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
AQUEOUS FOAM NRC: Aqueous Foam Related Incidents Listing The National Response Center (NRC) serves as an emergency call center that fields initial reports for pollution and railroad incidents and forwards that information to appropriate federal/state agencies for response. The spreadsheets posted to the NRC website contain initial incident data that has not been validated or investigated by a federal/state response agency. Response center calls from 1990 to the most recent complete calendar year where there was indication of Aqueous Film Forming Foam (AFFF) usage are included in this dataset. NRC calls may reference AFFF usage in the ?Material Involved? or ?Incident Description? fields.
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/06/2023
Date Made Active in Reports: 09/25/2023
Number of Days to Update: 81
Source: Environmental Protection Agency
Telephone: 202-267-2675
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
TC7493604.2s Page GR-29
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
PCS: Permit Compliance System
PCS is a computerized management information system that contains data on National Pollutant Discharge Elimination System (NPDES) permit holding facilities. PCS tracks the permit, compliance, and enforcement status of NPDES facilities.
Date of Government Version: 07/14/2011
Date Data Arrived at EDR: 08/05/2011
Date Made Active in Reports: 09/29/2011
Number of Days to Update: 55
Source: EPA, Office of Water
Telephone: 202-564-2496
Last EDR Contact: 09/28/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: No Update Planned
PCS ENF: Enforcement data
No description is available for this data
Date of Government Version: 12/31/2014
Date Data Arrived at EDR: 02/05/2015
Date Made Active in Reports: 03/06/2015
Number of Days to Update: 29
Source: EPA
Telephone: 202-564-2497
Last EDR Contact: 09/28/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
BIOSOLIDS: ICIS-NPDES Biosolids Facility Data
The data reflects compliance information about facilities in the biosolids program.
Date of Government Version: 07/16/2023
Date Data Arrived at EDR: 07/18/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 41
Source: Environmental Protection Agency
Telephone: 202-564-4700
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
PFAS: PFAS Contamination Site Location Listing
A listing of PFAS contaminated sites included in the GeoTracker database.
Date of Government Version: 06/02/2023
Date Data Arrived at EDR: 06/02/2023
Date Made Active in Reports: 08/23/2023
Number of Days to Update: 82
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
AQUEOUS FOAM: Former Fire Training Facility Assessments Listing Airports shown on this list are those believed to use Aqueous Film Forming Foam (AFFF), and certified by the Federal Aviation Administration (FAA) under Title 14, Code of Federal Regulations (CFR), Part 139 (14 CFR Part 139). This list was created by SWRCB using information available from the FAA. Location points shown are from the latitude and longitude listed on the FAA airport master record.
Date of Government Version: 06/02/2023
Date Data Arrived at EDR: 06/02/2023
Date Made Active in Reports: 08/23/2023
Number of Days to Update: 82
Source: State Water Resources Control Board
Telephone: 916-341-5455
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
CA BOND EXP. PLAN: Bond Expenditure Plan
Department of Health Services developed a site-specific expenditure plan as the basis for an appropriation of Hazardous Substance Cleanup Bond Act funds. It is not updated.
Date of Government Version: 01/01/1989
Date Data Arrived at EDR: 07/27/1994
Date Made Active in Reports: 08/02/1994
Number of Days to Update: 6
Source: Department of Health Services
Telephone: 916-255-2118
Last EDR Contact: 05/31/1994
Next Scheduled EDR Contact: N/A
Data Release Frequency: No Update Planned
TC7493604.2s Page GR-30
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
CHROME PLATING: Chrome Plating Facilities Listing
This listing represents chrome plating facilities the California State Water Resources Control Board staff identified as possibly being a source of Per- and polyfluoroalkyl substance (PFAS) contamination. Sites and locations were identified by staff with the Division of Water Quality in the California State Water Board. Data was collected from the CA Air Resources Board 2013 and 2018 - Cr VI emission survey, CA Emission Inventory, CA HAZ Waste discharge database and by reviewing storm water permits. Former chrome plating sites are also included that are open site investigation or remediation cases with the Regional Water Quality Control Boards and the Department of Toxic Substances Control.
Date of Government Version: 06/08/2023
Date Data Arrived at EDR: 06/08/2023
Date Made Active in Reports: 09/26/2023
Number of Days to Update: 110
Source: State Water Resources Control Board
Telephone: 916-341-5455
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
CORTESE: "Cortese" Hazardous Waste & Substances Sites List The sites for the list are designated by the State Water Resource Control Board (LUST), the Integrated Waste Board (SWF/LS), and the Department of Toxic Substances Control (Cal-Sites).
Date of Government Version: 06/14/2023
Date Data Arrived at EDR: 06/14/2023
Date Made Active in Reports: 09/06/2023
Number of Days to Update: 84
Source: CAL EPA/Office of Emergency Information
Telephone: 916-323-3400
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
CUPA LIVERMORE-PLEASANTON: CUPA Facility Listing
list of facilities associated with the various CUPA programs in Livermore-Pleasanton Date of Government Version: 03/31/2023
Date Data Arrived at EDR: 05/08/2023
Date Made Active in Reports: 07/31/2023
Number of Days to Update: 84
Source: Livermore-Pleasanton Fire Department
Telephone: 925-454-2361
Last EDR Contact: 08/10/2023
Next Scheduled EDR Contact: 11/20/2023
Data Release Frequency: Varies
DRYCLEAN SACRAMENTO METO DIST: Sacramento Metropolitan Air Quality Management DistrictDrycleaner Facility Listing A listing of drycleaner facility locations, for the Sacramento Metropolitan Air Quality Management District.
Date of Government Version: 08/15/2023
Date Data Arrived at EDR: 08/17/2023
Date Made Active in Reports: 10/31/2023
Number of Days to Update: 75
Source: Sacramento Metropolitan Air Quality Management District Telephone: 916-874-3958
Last EDR Contact: 08/15/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN SAN DIEGO CO DIST: San Diego County Air Pollution Control District Drycleaner Facility Listing A listing of drycleaner facility locations, for the San Diego County Air Pollution Control District.
Date of Government Version: 08/08/2023
Date Data Arrived at EDR: 08/09/2023
Date Made Active in Reports: 10/26/2023
Number of Days to Update: 78
Source: San Diego County Air Pollution Control District Telephone: 858-586-2616
Last EDR Contact: 08/08/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEANERS: Cleaner Facilities
A list of drycleaner related facilities that have EPA ID numbers. These are facilities with certain SIC codes:
power laundries, family and commercial; garment pressing and cleaner’s agents; linen supply; coin-operated laundries and cleaning; drycleaning plants, except rugs; carpet and upholster cleaning; industrial launderers; laundry and garment services.
Date of Government Version: 08/27/2021
Date Data Arrived at EDR: 09/01/2021
Date Made Active in Reports: 11/19/2021
Number of Days to Update: 79
Source: Department of Toxic Substance Control
Telephone: 916-327-4498
Last EDR Contact: 08/22/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Annually
TC7493604.2s Page GR-31
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
DRYCLEAN FEATHER RIVER DIST: Feather River Air Quality Management District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Feather River Air Quality Management District.
Date of Government Version: 03/08/2023
Date Data Arrived at EDR: 03/09/2023
Date Made Active in Reports: 06/05/2023
Number of Days to Update: 88
Source: Feather River Air Quality Management District
Telephone: 530-634-7659
Last EDR Contact: 06/08/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN SOUTH COAST: South Coast Air Quality Management District Drycleaner Listing A listing of dry cleaners in the South Coast Air Quality Management District Date of Government Version: 08/18/2023
Date Data Arrived at EDR: 08/18/2023
Date Made Active in Reports: 11/01/2023
Number of Days to Update: 75
Source: South Coast Air Quality Management District
Telephone: 909-396-3211
Last EDR Contact: 08/15/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Varies
DRYCLEAN AVAQMD: Antelope Valley Air Quality Management District Drycleaner Listing A listing of dry cleaners in the Antelope Valley Air Quality Management District.
Date of Government Version: 08/22/2023
Date Data Arrived at EDR: 08/24/2023
Date Made Active in Reports: 11/07/2023
Number of Days to Update: 75
Source: Antelope Valley Air Quality Management District Telephone: 661-723-8070
Last EDR Contact: 08/22/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Varies
DRYCLEAN SAN JOAQ VAL DIST: San Joaquin Valley Air Pollution Control District District Drycleaner Facility Listing A listing of drycleaner facility locations, for the San Joaquin Valley Air Pollution Control District.
Date of Government Version: 05/24/2023
Date Data Arrived at EDR: 05/30/2023
Date Made Active in Reports: 08/21/2023
Number of Days to Update: 83
Source: San Joaquin Valley Air Pollution Control District Telephone: 559-230-6001
Last EDR Contact: 05/11/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN SAN LUIS OB CO DIST: San Luis Obispo County Air Pollution Control District Drycleaner Facility Listing A listing of drycleaner facility locations, for the San Luis Obispo County Air Pollution Control District.
Date of Government Version: 07/26/2023
Date Data Arrived at EDR: 07/27/2023
Date Made Active in Reports: 10/13/2023
Number of Days to Update: 78
Source: San Luis Obispo County Air Pollution Control District Telephone: 805-781-5756
Last EDR Contact: 07/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN GLENN CO DIST: Glenn County Air Pollution Control District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Glenn County Air Pollution Control District.
Date of Government Version: 05/02/2023
Date Data Arrived at EDR: 05/03/2023
Date Made Active in Reports: 07/25/2023
Number of Days to Update: 83
Source: Glenn County Air Pollution Control District
Telephone: 530-934-6500
Last EDR Contact: 05/03/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN EAST KERN DIST: Eastern Kern Air Pollution Control District District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Eastern Kern Air Pollution Control District.
Date of Government Version: 01/12/2023
Date Data Arrived at EDR: 04/26/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 79
Source: Eastern Kern Air Pollution Control District
Telephone: 661-862-9684
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
TC7493604.2s Page GR-32
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
DRYCLEAN IMPERIAL CO DIST: Imperial County Air Pollution Control District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Imperial County Air Pollution Control District Date of Government Version: 04/25/2023
Date Data Arrived at EDR: 04/26/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 79
Source: Imperial County Air Pollution Control District
Telephone: 442-265-1800
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN MENDO CO DIST: Mendocino County Air Quality Management District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Mendocino County Air Quality Management District.
Date of Government Version: 04/27/2023
Date Data Arrived at EDR: 04/28/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 77
Source: Mendocino County Air Quality Management District Telephone: 707-463-4354
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN MOJAVE DESERT DIST: Mojave Desert Air Quality Management District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Mojave Desert Air Quality Management District.
Date of Government Version: 04/26/2023
Date Data Arrived at EDR: 04/27/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 78
Source: Mojave Desert Air Quality Management District
Telephone: 760-245-1661
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN MONTEREY BAY DIST: Monterey Bay Air Quality Management District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Monterey Bay Air Quality Management District.
Date of Government Version: 04/25/2023
Date Data Arrived at EDR: 04/26/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 79
Source: Monterey Bay Air Quality Management District
Telephone: 831-647-9411
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN SHASTA CO DIST: Shasta County Air Quality Management District District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Shasta County Air Quality Management District.
Date of Government Version: 04/26/2023
Date Data Arrived at EDR: 04/27/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 78
Source: Shasta County Air Quality Management District
Telephone: 530-225-5674
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN YOLO-SOLANO DIST: Yolo-Solano Air Quality Management District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Yolo-Solano Air Quality Management District.
Date of Government Version: 04/25/2023
Date Data Arrived at EDR: 04/27/2023
Date Made Active in Reports: 07/14/2023
Number of Days to Update: 78
Source: Yolo-Solano Air Quality Management District
Telephone: 530-757-3650
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN PLACER CO DIST: Placer County Air Quality Management District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Placer County Air Quality Management District.
Date of Government Version: 05/15/2023
Date Data Arrived at EDR: 05/17/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 89
Source: Placer County Air Quality Management District
Telephone: 530-745-2335
Last EDR Contact: 05/11/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
TC7493604.2s Page GR-33
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
DRYCLEAN BAY AREA DIST: Bay Area Air Quality Management District Drycleaner Facility Listing Bay Area Air Quality Management District Drycleaner Facility Listing.
Date of Government Version: 02/20/2019
Date Data Arrived at EDR: 05/30/2019
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 1432
Source: Bay Area Air Quality Management District
Telephone: 415-516-1916
Last EDR Contact: 07/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN BUTTE CO DIST: Butte County Air Quality Management DistrictDrycleaner Facility Listing Butte County Air Quality Management DistrictDrycleaner Facility Listing.
Date of Government Version: 12/31/2018
Date Data Arrived at EDR: 04/23/2019
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 1469
Source: Butte County Air Quality Management District
Telephone: 530-332-9400
Last EDR Contact: 10/03/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN CALAVERAS CO DIST: Calaveras County Environmental Management Agency Drycleaner Facility Listing A listing of drycleaner facility locations, for the Calaveras County Environmental Management Agency.
Date of Government Version: 06/17/2019
Date Data Arrived at EDR: 06/19/2019
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 1412
Source: Calaveras County Environmental Management Agency Telephone: 209-754-6399
Last EDR Contact: 04/24/2023
Next Scheduled EDR Contact: 09/16/2019
Data Release Frequency: Varies
DRYCLEAN GRANT: Grant Recipients List
Assembly Bill 998 (AB 998) established the Non-Toxic Dry Cleaning Incentive Program to provide financial assistance to the dry cleaning industry to switch from systems using perchloroethylene (Perc), an identified toxic air contaminant and potential human carcinogen, to non-toxic and non-smog forming alternatives.
Date of Government Version: 12/31/2020
Date Data Arrived at EDR: 02/04/2021
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 816
Source: California Air Resources Board
Telephone: 916-323-0006
Last EDR Contact: 10/28/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Varies
DRYCLEAN LAKE CO DIST: Lake County Air Quality Management District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Lake County Air Quality Management District, Date of Government Version: 04/29/2019
Date Data Arrived at EDR: 05/07/2019
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 1455
Source: Lake County Air Quality Management District
Telephone: 707-263-7000
Last EDR Contact: 05/11/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN NO COAST UNIFIED DIST: North Coast Unified Air Quality Management District Drycleaner Facility Listing A listing of drycleaner facility locations, for the North Coast Unified Air Quality Management District.
Date of Government Version: 11/30/2016
Date Data Arrived at EDR: 04/19/2019
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 1473
Source: North Coast Unified Air Quality Management District Telephone: 707-443-3093
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN NO SIERRA DIST: Northern Sierra Air Quality Management District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Northern Sierra Air Quality Management District, Date of Government Version: 05/07/2019
Date Data Arrived at EDR: 05/07/2019
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 1455
Source: Northern Sierra Air Quality Management District Telephone: 530-274-9350
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
TC7493604.2s Page GR-34
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
DRYCLEAN NO SONOMA CO DIST: Norther Sonoma County County Air Pollution Control District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Northern Sonoma County Air Pollution Control District., Date of Government Version: 04/17/2019
Date Data Arrived at EDR: 04/17/2019
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 1475
Source: Santa Barbara County Air Pollution Control District Telephone: 707-433-5911
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN SANTA BARB CO DIST: Santa Barbara County Air Pollution Control District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Santa Barbara County Air Pollution Control District.
Date of Government Version: 02/19/2019
Date Data Arrived at EDR: 04/17/2019
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 1475
Source: Santa Barbara County Air Pollution Control District Telephone: 805-961-8867
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN TEHAMA CO DIST: Tehama County Air Pollution Control District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Tehama County Air Pollution Control District.
Date of Government Version: 04/24/2019
Date Data Arrived at EDR: 04/24/2019
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 1468
Source: Tehama County Air Pollution Control District
Telephone: 530-527-3717
Last EDR Contact: 04/25/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN VENTURA CO DIST: Drycleaner Facility Listing
A listing of drycleaner facility locations, for the Ventura County Air Pollution Control District.
Date of Government Version: 04/16/2019
Date Data Arrived at EDR: 04/17/2019
Date Made Active in Reports: 05/01/2023
Number of Days to Update: 1475
Source: Ventura County Air Pollution Control District
Telephone: 805-645-1421
Last EDR Contact: 10/11/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
DRYCLEAN AMADOR: Amador Air District Drycleaner Facility Listing A listing of drycleaner facility locations, for the Amador Air Quality Management District Date of Government Version: 04/26/2023
Date Data Arrived at EDR: 04/27/2023
Date Made Active in Reports: 07/13/2023
Number of Days to Update: 77
Source: Amador Air Quality Management District
Telephone: 209-257-0112
Last EDR Contact: 04/24/2023
Next Scheduled EDR Contact: 09/11/2023
Data Release Frequency: Varies
EMI: Emissions Inventory Data
Toxics and criteria pollutant emissions data collected by the ARB and local air pollution agencies.
Date of Government Version: 12/31/2021
Date Data Arrived at EDR: 06/09/2023
Date Made Active in Reports: 08/30/2023
Number of Days to Update: 82
Source: California Air Resources Board
Telephone: 916-322-2990
Last EDR Contact: 09/15/2023
Next Scheduled EDR Contact: 12/25/2023
Data Release Frequency: Varies
ENF: Enforcement Action Listing
A listing of Water Board Enforcement Actions. Formal is everything except Oral/Verbal Communication, Notice of Violation, Expedited Payment Letter, and Staff Enforcement Letter.
Date of Government Version: 07/17/2023
Date Data Arrived at EDR: 07/18/2023
Date Made Active in Reports: 10/05/2023
Number of Days to Update: 79
Source: State Water Resoruces Control Board
Telephone: 916-445-9379
Last EDR Contact: 10/17/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
TC7493604.2s Page GR-35
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Financial Assurance 1: Financial Assurance Information Listing Financial Assurance information
Date of Government Version: 09/13/2023
Date Data Arrived at EDR: 09/14/2023
Date Made Active in Reports: 09/21/2023
Number of Days to Update: 7
Source: Department of Toxic Substances Control
Telephone: 916-255-3628
Last EDR Contact: 09/13/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
Financial Assurance 2: Financial Assurance Information Listing A listing of financial assurance information for solid waste facilities. Financial assurance is intended to ensure that resources are available to pay for the cost of closure, post-closure care, and corrective measures if the owner or operator of a regulated facility is unable or unwilling to pay.
Date of Government Version: 08/03/2023
Date Data Arrived at EDR: 08/16/2023
Date Made Active in Reports: 11/01/2023
Number of Days to Update: 77
Source: California Integrated Waste Management Board
Telephone: 916-341-6066
Last EDR Contact: 11/02/2023
Next Scheduled EDR Contact: 02/19/2024
Data Release Frequency: Varies
ICE: Inspection, Compliance and Enforcement
Contains data pertaining to the Permitted Facilities with Inspections / Enforcements sites tracked in Envirostor.
Date of Government Version: 08/14/2023
Date Data Arrived at EDR: 08/14/2023
Date Made Active in Reports: 10/31/2023
Number of Days to Update: 78
Source: Department of Toxic Subsances Control
Telephone: 877-786-9427
Last EDR Contact: 08/14/2023
Next Scheduled EDR Contact: 11/27/2023
Data Release Frequency: Quarterly
HIST CORTESE: Hazardous Waste & Substance Site List
The sites for the list are designated by the State Water Resource Control Board [LUST], the Integrated Waste Board [SWF/LS], and the Department of Toxic Substances Control [CALSITES]. This listing is no longer updated by the state agency.
Date of Government Version: 04/01/2001
Date Data Arrived at EDR: 01/22/2009
Date Made Active in Reports: 04/08/2009
Number of Days to Update: 76
Source: Department of Toxic Substances Control
Telephone: 916-323-3400
Last EDR Contact: 01/22/2009
Next Scheduled EDR Contact: N/A
Data Release Frequency: No Update Planned
HWP: EnviroStor Permitted Facilities Listing
Detailed information on permitted hazardous waste facilities and corrective action ("cleanups") tracked in EnviroStor.
Date of Government Version: 08/14/2023
Date Data Arrived at EDR: 08/14/2023
Date Made Active in Reports: 10/31/2023
Number of Days to Update: 78
Source: Department of Toxic Substances Control
Telephone: 916-323-3400
Last EDR Contact: 08/14/2023
Next Scheduled EDR Contact: 11/27/2023
Data Release Frequency: Quarterly
HWT: Registered Hazardous Waste Transporter Database
A listing of hazardous waste transporters. In California, unless specifically exempted, it is unlawful for any person to transport hazardous wastes unless the person holds a valid registration issued by DTSC. A hazardous waste transporter registration is valid for one year and is assigned a unique registration number.
Date of Government Version: 06/29/2023
Date Data Arrived at EDR: 06/29/2023
Date Made Active in Reports: 09/19/2023
Number of Days to Update: 82
Source: Department of Toxic Substances Control
Telephone: 916-440-7145
Last EDR Contact: 10/04/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Quarterly
TC7493604.2s Page GR-36
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
HWTS: Hazardous Waste Tracking System
DTSC maintains the Hazardous Waste Tracking System that stores ID number information since the early 1980s and manifest data since 1993. The system collects both manifest copies from the generator and destination facility.
Date of Government Version: 08/04/2023
Date Data Arrived at EDR: 08/09/2023
Date Made Active in Reports: 10/26/2023
Number of Days to Update: 78
Source: Department of Toxic Substances Control
Telephone: 916-324-2444
Last EDR Contact: 09/27/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
HAZNET: Facility and Manifest Data
Facility and Manifest Data. The data is extracted from the copies of hazardous waste manifests received each year by the DTSC. The annual volume of manifests is typically 700,000 - 1,000,000 annually, representing approximately 350,000 - 500,000 shipments. Data are from the manifests submitted without correction, and therefore many contain some invalid values for data elements such as generator ID, TSD ID, waste category, and disposal method. This database begins with calendar year 1993.
Date of Government Version: 12/31/2021
Date Data Arrived at EDR: 07/05/2022
Date Made Active in Reports: 09/19/2022
Number of Days to Update: 76
Source: California Environmental Protection Agency
Telephone: 916-255-1136
Last EDR Contact: 07/05/2022
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Annually
MINES: Mines Site Location Listing
A listing of mine site locations from the Office of Mine Reclamation.
Date of Government Version: 06/02/2023
Date Data Arrived at EDR: 06/02/2023
Date Made Active in Reports: 08/23/2023
Number of Days to Update: 82
Source: Department of Conservation
Telephone: 916-322-1080
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Quarterly
MWMP: Medical Waste Management Program Listing
The Medical Waste Management Program (MWMP) ensures the proper handling and disposal of medical waste by permitting and inspecting medical waste Offsite Treatment Facilities (PDF) and Transfer Stations (PDF) throughout the state. MWMP also oversees all Medical Waste Transporters.
Date of Government Version: 05/08/2023
Date Data Arrived at EDR: 05/25/2023
Date Made Active in Reports: 08/16/2023
Number of Days to Update: 83
Source: Department of Public Health
Telephone: 916-558-1784
Last EDR Contact: 08/29/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Varies
NPDES: NPDES Permits Listing
A listing of NPDES permits, including stormwater.
Date of Government Version: 08/07/2023
Date Data Arrived at EDR: 08/08/2023
Date Made Active in Reports: 10/26/2023
Number of Days to Update: 79
Source: State Water Resources Control Board
Telephone: 916-445-9379
Last EDR Contact: 11/07/2023
Next Scheduled EDR Contact: 02/19/2024
Data Release Frequency: Quarterly
PEST LIC: Pesticide Regulation Licenses Listing
A listing of licenses and certificates issued by the Department of Pesticide Regulation. The DPR issues licenses and/or certificates to: Persons and businesses that apply or sell pesticides; Pest control dealers and brokers; Persons who advise on agricultural pesticide applications.
Date of Government Version: 05/25/2023
Date Data Arrived at EDR: 05/25/2023
Date Made Active in Reports: 08/16/2023
Number of Days to Update: 83
Source: Department of Pesticide Regulation
Telephone: 916-445-4038
Last EDR Contact: 08/29/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Quarterly
TC7493604.2s Page GR-37
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
PROC: Certified Processors Database
A listing of certified processors.
Date of Government Version: 06/02/2023
Date Data Arrived at EDR: 06/02/2023
Date Made Active in Reports: 08/23/2023
Number of Days to Update: 82
Source: Department of Conservation
Telephone: 916-323-3836
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Quarterly
NOTIFY 65: Proposition 65 Records
Listings of all Proposition 65 incidents reported to counties by the State Water Resources Control Board and the Regional Water Quality Control Board. This database is no longer updated by the reporting agency.
Date of Government Version: 06/06/2023
Date Data Arrived at EDR: 06/07/2023
Date Made Active in Reports: 08/25/2023
Number of Days to Update: 79
Source: State Water Resources Control Board
Telephone: 916-445-3846
Last EDR Contact: 09/07/2023
Next Scheduled EDR Contact: 12/25/2023
Data Release Frequency: No Update Planned
SAN JOSE HAZMAT: Hazardous Material Facilities
Hazardous material facilities, including underground storage tank sites.
Date of Government Version: 11/03/2020
Date Data Arrived at EDR: 11/05/2020
Date Made Active in Reports: 01/26/2021
Number of Days to Update: 82
Source: City of San Jose Fire Department
Telephone: 408-535-7694
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Annually
SANTA CRUZ CO SITE MITI: Site Mitigation Listing
Sites may become contaminated with toxic chemicals through illegal dumping or disposal, from leaking underground storage tanks, or through industrial or commercial activities.The goal of the site mitigation program is to protect the public health and the environment while facilitating completion of contaminated site clean-up projects in a timely manner.
Date of Government Version: 12/03/2018
Date Data Arrived at EDR: 06/23/2023
Date Made Active in Reports: 07/13/2023
Number of Days to Update: 20
Source: Santa Cruz Environmental Health Services
Telephone: 831-454-2761
Last EDR Contact: 08/09/2023
Next Scheduled EDR Contact: 11/27/2023
Data Release Frequency: Varies
UIC: UIC Listing
A listing of wells identified as underground injection wells, in the California Oil and Gas Wells database.
Date of Government Version: 06/02/2023
Date Data Arrived at EDR: 06/02/2023
Date Made Active in Reports: 08/23/2023
Number of Days to Update: 82
Source: Deaprtment of Conservation
Telephone: 916-445-2408
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
UIC GEO: Underground Injection Control Sites (GEOTRACKER) Underground control injection sites
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resource Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
WASTEWATER PITS: Oil Wastewater Pits Listing
Water officials discovered that oil producers have been dumping chemical-laden wastewater into hundreds of unlined pits that are operating without proper permits. Inspections completed by the Central Valley Regional Water Quality Control Board revealed the existence of previously unidentified waste sites. The water boards review found that more than one-third of the region’s active disposal pits are operating without permission.
TC7493604.2s Page GR-38
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 02/11/2021
Date Data Arrived at EDR: 07/01/2021
Date Made Active in Reports: 09/29/2021
Number of Days to Update: 90
Source: RWQCB, Central Valley Region
Telephone: 559-445-5577
Last EDR Contact: 10/06/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Varies
WDS: Waste Discharge System
Sites which have been issued waste discharge requirements.
Date of Government Version: 06/19/2007
Date Data Arrived at EDR: 06/20/2007
Date Made Active in Reports: 06/29/2007
Number of Days to Update: 9
Source: State Water Resources Control Board
Telephone: 916-341-5227
Last EDR Contact: 08/09/2023
Next Scheduled EDR Contact: 11/27/2023
Data Release Frequency: No Update Planned
WIP: Well Investigation Program Case List
Well Investigation Program case in the San Gabriel and San Fernando Valley area.
Date of Government Version: 07/03/2009
Date Data Arrived at EDR: 07/21/2009
Date Made Active in Reports: 08/03/2009
Number of Days to Update: 13
Source: Los Angeles Water Quality Control Board
Telephone: 213-576-6726
Last EDR Contact: 09/12/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: No Update Planned
MILITARY PRIV SITES: Military Privatized Sites (GEOTRACKER) Military privatized sites
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
PROJECT: Project Sites (GEOTRACKER)
Projects sites
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
WDR: Waste Discharge Requirements Listing
In general, the Waste Discharge Requirements (WDRs) Program (sometimes also referred to as the "Non Chapter 15 (Non 15) Program") regulates point discharges that are exempt pursuant to Subsection 20090 of Title 27 and not subject to the Federal Water Pollution Control Act. Exemptions from Title 27 may be granted for nine categories of discharges (e.g., sewage, wastewater, etc.) that meet, and continue to meet, the preconditions listed for each specific exemption. The scope of the WDRs Program also includes the discharge of wastes classified as inert, pursuant to section 20230 of Title 27.
Date of Government Version: 06/02/2023
Date Data Arrived at EDR: 06/02/2023
Date Made Active in Reports: 08/23/2023
Number of Days to Update: 82
Source: State Water Resources Control Board
Telephone: 916-341-5810
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Quarterly
CIWQS: California Integrated Water Quality System
The California Integrated Water Quality System (CIWQS) is a computer system used by the State and Regional Water Quality Control Boards to track information about places of environmental interest, manage permits and other orders, track inspections, and manage violations and enforcement activities.
TC7493604.2s Page GR-39
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 05/25/2023
Date Data Arrived at EDR: 05/25/2023
Date Made Active in Reports: 08/14/2023
Number of Days to Update: 81
Source: State Water Resources Control Board
Telephone: 866-794-4977
Last EDR Contact: 08/29/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Varies
CERS: CalEPA Regulated Site Portal Data
The CalEPA Regulated Site Portal database combines data about environmentally regulated sites and facilities in California into a single database. It combines data from a variety of state and federal databases, and provides an overview of regulated activities across the spectrum of environmental programs for any given location in California.
These activities include hazardous materials and waste, state and federal cleanups, impacted ground and surface waters, and toxic materials
Date of Government Version: 07/17/2023
Date Data Arrived at EDR: 07/18/2023
Date Made Active in Reports: 10/06/2023
Number of Days to Update: 80
Source: California Environmental Protection Agency
Telephone: 916-323-2514
Last EDR Contact: 10/17/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
NON-CASE INFO: Non-Case Information Sites (GEOTRACKER)
Non-Case Information sites
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
OTHER OIL GAS: Other Oil & Gas Projects Sites (GEOTRACKER) Other Oil & Gas Projects sites
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
PROD WATER PONDS: Produced Water Ponds Sites (GEOTRACKER) Produced water ponds sites
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
SAMPLING POINT: Sampling Point ? Public Sites (GEOTRACKER) Sampling point - public sites
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
WELL STIM PROJ: Well Stimulation Project (GEOTRACKER)
Includes areas of groundwater monitoring plans, a depiction of the monitoring network, and the facilities, boundaries, and subsurface characteristics of the oilfield and the features (oil and gas wells, produced water ponds, UIC wells, water supply wells, etc?) being monitored
TC7493604.2s Page GR-40
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 06/05/2023
Date Data Arrived at EDR: 06/05/2023
Date Made Active in Reports: 08/28/2023
Number of Days to Update: 84
Source: State Water Resources Control Board
Telephone: 866-480-1028
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Varies
EDR HIGH RISK HISTORICAL RECORDS
EDR Exclusive Records
EDR MGP: EDR Proprietary Manufactured Gas Plants
The EDR Proprietary Manufactured Gas Plant Database includes records of coal gas plants (manufactured gas plants) compiled by EDR’s researchers. Manufactured gas sites were used in the United States from the 1800’s to 1950’s to produce a gas that could be distributed and used as fuel. These plants used whale oil, rosin, coal, or a mixture of coal, oil, and water that also produced a significant amount of waste. Many of the byproducts of the gas production, such as coal tar (oily waste containing volatile and non-volatile chemicals), sludges, oils and other compounds are potentially hazardous to human health and the environment. The byproduct from this process was frequently disposed of directly at the plant site and can remain or spread slowly, serving as a continuous source of soil and groundwater contamination.
Date of Government Version: N/A
Date Data Arrived at EDR: N/A
Date Made Active in Reports: N/A
Number of Days to Update: N/A
Source: EDR, Inc.
Telephone: N/A
Last EDR Contact: N/A
Next Scheduled EDR Contact: N/A
Data Release Frequency: No Update Planned
EDR Hist Auto: EDR Exclusive Historical Auto Stations
EDR has searched selected national collections of business directories and has collected listings of potential gas station/filling station/service station sites that were available to EDR researchers. EDR’s review was limited to those categories of sources that might, in EDR’s opinion, include gas station/filling station/service station establishments. The categories reviewed included, but were not limited to gas, gas station, gasoline station, filling station, auto, automobile repair, auto service station, service station, etc. This database falls within a category of information EDR classifies as "High Risk Historical Records", or HRHR. EDR’s HRHR effort presents unique and sometimes proprietary data about past sites and operations that typically create environmental concerns, but may not show up in current government records searches.
Date of Government Version: N/A
Date Data Arrived at EDR: N/A
Date Made Active in Reports: N/A
Number of Days to Update: N/A
Source: EDR, Inc.
Telephone: N/A
Last EDR Contact: N/A
Next Scheduled EDR Contact: N/A
Data Release Frequency: Varies
EDR Hist Cleaner: EDR Exclusive Historical Cleaners
EDR has searched selected national collections of business directories and has collected listings of potential dry cleaner sites that were available to EDR researchers. EDR’s review was limited to those categories of sources that might, in EDR’s opinion, include dry cleaning establishments. The categories reviewed included, but were not limited to dry cleaners, cleaners, laundry, laundromat, cleaning/laundry, wash & dry etc. This database falls within a category of information EDR classifies as "High Risk Historical Records", or HRHR. EDR’s HRHR effort presents unique and sometimes proprietary data about past sites and operations that typically create environmental concerns, but may not show up in current government records searches.
Date of Government Version: N/A
Date Data Arrived at EDR: N/A
Date Made Active in Reports: N/A
Number of Days to Update: N/A
Source: EDR, Inc.
Telephone: N/A
Last EDR Contact: N/A
Next Scheduled EDR Contact: N/A
Data Release Frequency: Varies
EDR RECOVERED GOVERNMENT ARCHIVES
Exclusive Recovered Govt. Archives
TC7493604.2s Page GR-41
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
RGA LF: Recovered Government Archive Solid Waste Facilities List The EDR Recovered Government Archive Landfill database provides a list of landfills derived from historical databases and includes many records that no longer appear in current government lists. Compiled from Records formerly available from the Department of Resources Recycling and Recovery in California.
Date of Government Version: N/A
Date Data Arrived at EDR: 07/01/2013
Date Made Active in Reports: 01/13/2014
Number of Days to Update: 196
Source: Department of Resources Recycling and Recovery
Telephone: N/A
Last EDR Contact: 06/01/2012
Next Scheduled EDR Contact: N/A
Data Release Frequency: Varies
RGA LUST: Recovered Government Archive Leaking Underground Storage Tank The EDR Recovered Government Archive Leaking Underground Storage Tank database provides a list of LUST incidents derived from historical databases and includes many records that no longer appear in current government lists.
Compiled from Records formerly available from the State Water Resources Control Board in California.
Date of Government Version: N/A
Date Data Arrived at EDR: 07/01/2013
Date Made Active in Reports: 12/30/2013
Number of Days to Update: 182
Source: State Water Resources Control Board
Telephone: N/A
Last EDR Contact: 06/01/2012
Next Scheduled EDR Contact: N/A
Data Release Frequency: Varies
COUNTY RECORDS
ALAMEDA COUNTY:
CS ALAMEDA: Contaminated Sites
A listing of contaminated sites overseen by the Toxic Release Program (oil and groundwater contamination from chemical releases and spills) and the Leaking Underground Storage Tank Program (soil and ground water contamination from leaking petroleum USTs).
Date of Government Version: 01/09/2019
Date Data Arrived at EDR: 01/11/2019
Date Made Active in Reports: 03/05/2019
Number of Days to Update: 53
Source: Alameda County Environmental Health Services
Telephone: 510-567-6700
Last EDR Contact: 09/27/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Semi-Annually
UST ALAMEDA: Underground Tanks
Underground storage tank sites located in Alameda county.
Date of Government Version: 06/27/2023
Date Data Arrived at EDR: 06/28/2023
Date Made Active in Reports: 09/14/2023
Number of Days to Update: 78
Source: Alameda County Environmental Health Services
Telephone: 510-567-6700
Last EDR Contact: 09/27/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Semi-Annually
AMADOR COUNTY:
CUPA AMADOR: CUPA Facility List
Cupa Facility List
Date of Government Version: 04/27/2023
Date Data Arrived at EDR: 04/27/2023
Date Made Active in Reports: 07/13/2023
Number of Days to Update: 77
Source: Amador County Environmental Health
Telephone: 209-223-6439
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
BUTTE COUNTY:
TC7493604.2s Page GR-42
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
CUPA BUTTE: CUPA Facility Listing
Cupa facility list.
Date of Government Version: 04/21/2017
Date Data Arrived at EDR: 04/25/2017
Date Made Active in Reports: 08/09/2017
Number of Days to Update: 106
Source: Public Health Department
Telephone: 530-538-7149
Last EDR Contact: 09/27/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: No Update Planned
CALVERAS COUNTY:
CUPA CALVERAS: CUPA Facility Listing
Cupa Facility Listing
Date of Government Version: 06/27/2023
Date Data Arrived at EDR: 06/28/2023
Date Made Active in Reports: 09/14/2023
Number of Days to Update: 78
Source: Calveras County Environmental Health
Telephone: 209-754-6399
Last EDR Contact: 09/12/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
COLUSA COUNTY:
CUPA COLUSA: CUPA Facility List
Cupa facility list.
Date of Government Version: 04/06/2020
Date Data Arrived at EDR: 04/23/2020
Date Made Active in Reports: 07/10/2020
Number of Days to Update: 78
Source: Health & Human Services
Telephone: 530-458-0396
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Semi-Annually
CONTRA COSTA COUNTY:
SL CONTRA COSTA: Site List
List includes sites from the underground tank, hazardous waste generator and business plan/2185 programs.
Date of Government Version: 07/05/2023
Date Data Arrived at EDR: 07/20/2023
Date Made Active in Reports: 10/05/2023
Number of Days to Update: 77
Source: Contra Costa Health Services Department
Telephone: 925-646-2286
Last EDR Contact: 10/20/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Semi-Annually
DEL NORTE COUNTY:
CUPA DEL NORTE: CUPA Facility List
Cupa Facility list
Date of Government Version: 08/02/2023
Date Data Arrived at EDR: 08/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 77
Source: Del Norte County Environmental Health Division
Telephone: 707-465-0426
Last EDR Contact: 10/20/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Varies
EL DORADO COUNTY:
TC7493604.2s Page GR-43
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
CUPA EL DORADO: CUPA Facility List
CUPA facility list.
Date of Government Version: 08/08/2022
Date Data Arrived at EDR: 08/09/2022
Date Made Active in Reports: 09/01/2022
Number of Days to Update: 23
Source: El Dorado County Environmental Management Department Telephone: 530-621-6623
Last EDR Contact: 10/20/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Varies
FRESNO COUNTY:
CUPA FRESNO: CUPA Resources List
Certified Unified Program Agency. CUPA’s are responsible for implementing a unified hazardous materials and hazardous waste management regulatory program. The agency provides oversight of businesses that deal with hazardous materials, operate underground storage tanks or aboveground storage tanks.
Date of Government Version: 06/28/2021
Date Data Arrived at EDR: 12/21/2021
Date Made Active in Reports: 03/03/2022
Number of Days to Update: 72
Source: Dept. of Community Health
Telephone: 559-445-3271
Last EDR Contact: 09/28/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Semi-Annually
GLENN COUNTY:
CUPA GLENN: CUPA Facility List
Cupa facility list
Date of Government Version: 01/22/2018
Date Data Arrived at EDR: 01/24/2018
Date Made Active in Reports: 03/14/2018
Number of Days to Update: 49
Source: Glenn County Air Pollution Control District
Telephone: 830-934-6500
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: No Update Planned
HUMBOLDT COUNTY:
CUPA HUMBOLDT: CUPA Facility List
CUPA facility list.
Date of Government Version: 08/12/2021
Date Data Arrived at EDR: 08/12/2021
Date Made Active in Reports: 11/08/2021
Number of Days to Update: 88
Source: Humboldt County Environmental Health
Telephone: N/A
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/26/2024
Data Release Frequency: Semi-Annually
IMPERIAL COUNTY:
CUPA IMPERIAL: CUPA Facility List
Cupa facility list.
Date of Government Version: 07/11/2023
Date Data Arrived at EDR: 07/12/2023
Date Made Active in Reports: 09/26/2023
Number of Days to Update: 76
Source: San Diego Border Field Office
Telephone: 760-339-2777
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
INYO COUNTY:
TC7493604.2s Page GR-44
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
CUPA INYO: CUPA Facility List
Cupa facility list.
Date of Government Version: 04/02/2018
Date Data Arrived at EDR: 04/03/2018
Date Made Active in Reports: 06/14/2018
Number of Days to Update: 72
Source: Inyo County Environmental Health Services
Telephone: 760-878-0238
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/26/2024
Data Release Frequency: Varies
KERN COUNTY:
CUPA KERN: CUPA Facility List
A listing of sites included in the Kern County Hazardous Material Business Plan.
Date of Government Version: 07/26/2023
Date Data Arrived at EDR: 07/27/2023
Date Made Active in Reports: 08/09/2023
Number of Days to Update: 13
Source: Kern County Public Health
Telephone: 661-321-3000
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
UST KERN: Underground Storage Tank Sites & Tank Listing Kern County Sites and Tanks Listing.
Date of Government Version: 07/26/2023
Date Data Arrived at EDR: 07/27/2023
Date Made Active in Reports: 08/03/2023
Number of Days to Update: 7
Source: Kern County Environment Health Services Department Telephone: 661-862-8700
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Quarterly
KINGS COUNTY:
CUPA KINGS: CUPA Facility List
A listing of sites included in the county’s Certified Unified Program Agency database. California’s Secretary for Environmental Protection established the unified hazardous materials and hazardous waste regulatory program as required by chapter 6.11 of the California Health and Safety Code. The Unified Program consolidates the administration, permits, inspections, and enforcement activities.
Date of Government Version: 12/03/2020
Date Data Arrived at EDR: 01/26/2021
Date Made Active in Reports: 04/14/2021
Number of Days to Update: 78
Source: Kings County Department of Public Health
Telephone: 559-584-1411
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/26/2024
Data Release Frequency: Varies
LAKE COUNTY:
CUPA LAKE: CUPA Facility List
Cupa facility list
Date of Government Version: 04/26/2023
Date Data Arrived at EDR: 04/27/2023
Date Made Active in Reports: 05/31/2023
Number of Days to Update: 34
Source: Lake County Environmental Health
Telephone: 707-263-1164
Last EDR Contact: 10/04/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: Varies
LASSEN COUNTY:
TC7493604.2s Page GR-45
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
CUPA LASSEN: CUPA Facility List
Cupa facility list
Date of Government Version: 07/31/2020
Date Data Arrived at EDR: 08/21/2020
Date Made Active in Reports: 11/09/2020
Number of Days to Update: 80
Source: Lassen County Environmental Health
Telephone: 530-251-8528
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
LOS ANGELES COUNTY:
AOCONCERN: Key Areas of Concerns in Los Angeles County
San Gabriel Valley areas where VOC contamination is at or above the MCL as designated by region 9 EPA office. Date of Government Version: 3/30/2009 Exide Site area is a cleanup plan of lead-impacted soil surrounding the former Exide Facility as designated by the DTSC. Date of Government Version: 7/17/2017 Date of Government Version: 03/30/2009
Date Data Arrived at EDR: 03/31/2009
Date Made Active in Reports: 10/23/2009
Number of Days to Update: 206
Source: N/A
Telephone: N/A
Last EDR Contact: 09/07/2023
Next Scheduled EDR Contact: 12/25/2023
Data Release Frequency: No Update Planned
HMS LOS ANGELES: HMS: Street Number List
Industrial Waste and Underground Storage Tank Sites.
Date of Government Version: 06/21/2023
Date Data Arrived at EDR: 06/28/2023
Date Made Active in Reports: 09/14/2023
Number of Days to Update: 78
Source: Department of Public Works
Telephone: 626-458-3517
Last EDR Contact: 09/27/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Semi-Annually
LF LOS ANGELES: List of Solid Waste Facilities
Solid Waste Facilities in Los Angeles County.
Date of Government Version: 07/10/2023
Date Data Arrived at EDR: 07/10/2023
Date Made Active in Reports: 09/27/2023
Number of Days to Update: 79
Source: La County Department of Public Works
Telephone: 818-458-5185
Last EDR Contact: 10/09/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: Varies
LF LOS ANGELES CITY: City of Los Angeles Landfills
Landfills owned and maintained by the City of Los Angeles.
Date of Government Version: 12/31/2022
Date Data Arrived at EDR: 01/12/2023
Date Made Active in Reports: 03/29/2023
Number of Days to Update: 76
Source: Engineering & Construction Division
Telephone: 213-473-7869
Last EDR Contact: 10/04/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: Varies
LOS ANGELES AST: Active & Inactive AST Inventory
A listing of active & inactive above ground petroleum storage tank site locations, located in the City of Los Angeles.
Date of Government Version: 06/01/2019
Date Data Arrived at EDR: 06/25/2019
Date Made Active in Reports: 08/22/2019
Number of Days to Update: 58
Source: Los Angeles Fire Department
Telephone: 213-978-3800
Last EDR Contact: 09/19/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Varies
TC7493604.2s Page GR-46
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
LOS ANGELES CO LF METHANE: Methane Producing Landfills
This data was created on April 30, 2012 to represent known disposal sites in Los Angeles County that may produce and emanate methane gas. The shapefile contains disposal sites within Los Angeles County that once accepted degradable refuse material. Information used to create this data was extracted from a landfill survey performed by County Engineers (Major Waste System Map, 1973) as well as historical records from CalRecycle, Regional Water Quality Control Board, and Los Angeles County Department of Public Health Date of Government Version: 04/13/2023
Date Data Arrived at EDR: 07/13/2023
Date Made Active in Reports: 09/27/2023
Number of Days to Update: 76
Source: Los Angeles County Department of Public Works
Telephone: 626-458-6973
Last EDR Contact: 10/04/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: No Update Planned
LOS ANGELES HM: Active & Inactive Hazardous Materials Inventory A listing of active & inactive hazardous materials facility locations, located in the City of Los Angeles.
Date of Government Version: 06/20/2023
Date Data Arrived at EDR: 06/22/2023
Date Made Active in Reports: 08/09/2023
Number of Days to Update: 48
Source: Los Angeles Fire Department
Telephone: 213-978-3800
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Varies
LOS ANGELES UST: Active & Inactive UST Inventory
A listing of active & inactive underground storage tank site locations and underground storage tank historical sites, located in the City of Los Angeles.
Date of Government Version: 06/20/2023
Date Data Arrived at EDR: 06/22/2023
Date Made Active in Reports: 09/12/2023
Number of Days to Update: 82
Source: Los Angeles Fire Department
Telephone: 213-978-3800
Last EDR Contact: 09/20/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Varies
SITE MIT LOS ANGELES: Site Mitigation List
Industrial sites that have had some sort of spill or complaint.
Date of Government Version: 03/02/2023
Date Data Arrived at EDR: 04/18/2023
Date Made Active in Reports: 07/07/2023
Number of Days to Update: 80
Source: Community Health Services
Telephone: 323-890-7806
Last EDR Contact: 10/17/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Annually
UST EL SEGUNDO: City of El Segundo Underground Storage Tank Underground storage tank sites located in El Segundo city.
Date of Government Version: 01/21/2017
Date Data Arrived at EDR: 04/19/2017
Date Made Active in Reports: 05/10/2017
Number of Days to Update: 21
Source: City of El Segundo Fire Department
Telephone: 310-524-2236
Last EDR Contact: 10/04/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: No Update Planned
UST LONG BEACH: City of Long Beach Underground Storage Tank Underground storage tank sites located in the city of Long Beach.
Date of Government Version: 04/22/2019
Date Data Arrived at EDR: 04/23/2019
Date Made Active in Reports: 06/27/2019
Number of Days to Update: 65
Source: City of Long Beach Fire Department
Telephone: 562-570-2563
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
TC7493604.2s Page GR-47
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
UST TORRANCE: City of Torrance Underground Storage Tank Underground storage tank sites located in the city of Torrance.
Date of Government Version: 04/12/2023
Date Data Arrived at EDR: 05/02/2023
Date Made Active in Reports: 06/13/2023
Number of Days to Update: 42
Source: City of Torrance Fire Department
Telephone: 310-618-2973
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Semi-Annually
MADERA COUNTY:
CUPA MADERA: CUPA Facility List
A listing of sites included in the county’s Certified Unified Program Agency database. California’s Secretary for Environmental Protection established the unified hazardous materials and hazardous waste regulatory program as required by chapter 6.11 of the California Health and Safety Code. The Unified Program consolidates the administration, permits, inspections, and enforcement activities.
Date of Government Version: 08/10/2020
Date Data Arrived at EDR: 08/12/2020
Date Made Active in Reports: 10/23/2020
Number of Days to Update: 72
Source: Madera County Environmental Health
Telephone: 559-675-7823
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/26/2024
Data Release Frequency: Varies
MARIN COUNTY:
UST MARIN: Underground Storage Tank Sites
Currently permitted USTs in Marin County.
Date of Government Version: 09/26/2018
Date Data Arrived at EDR: 10/04/2018
Date Made Active in Reports: 11/02/2018
Number of Days to Update: 29
Source: Public Works Department Waste Management
Telephone: 415-473-6647
Last EDR Contact: 09/21/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Semi-Annually
MENDOCINO COUNTY:
UST MENDOCINO: Mendocino County UST Database
A listing of underground storage tank locations in Mendocino County.
Date of Government Version: 09/22/2021
Date Data Arrived at EDR: 11/18/2021
Date Made Active in Reports: 11/22/2021
Number of Days to Update: 4
Source: Department of Public Health
Telephone: 707-463-4466
Last EDR Contact: 08/15/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Annually
MERCED COUNTY:
CUPA MERCED: CUPA Facility List
CUPA facility list.
Date of Government Version: 07/25/2023
Date Data Arrived at EDR: 08/03/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 77
Source: Merced County Environmental Health
Telephone: 209-381-1094
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/26/2024
Data Release Frequency: Varies
MONO COUNTY:
TC7493604.2s Page GR-48
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
CUPA MONO: CUPA Facility List
CUPA Facility List
Date of Government Version: 02/22/2021
Date Data Arrived at EDR: 03/02/2021
Date Made Active in Reports: 05/19/2021
Number of Days to Update: 78
Source: Mono County Health Department
Telephone: 760-932-5580
Last EDR Contact: 08/15/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: Varies
MONTEREY COUNTY:
CUPA MONTEREY: CUPA Facility Listing
CUPA Program listing from the Environmental Health Division.
Date of Government Version: 10/04/2021
Date Data Arrived at EDR: 10/06/2021
Date Made Active in Reports: 12/29/2021
Number of Days to Update: 84
Source: Monterey County Health Department
Telephone: 831-796-1297
Last EDR Contact: 11/02/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Varies
NAPA COUNTY:
LUST NAPA: Sites With Reported Contamination
A listing of leaking underground storage tank sites located in Napa county.
Date of Government Version: 01/09/2017
Date Data Arrived at EDR: 01/11/2017
Date Made Active in Reports: 03/02/2017
Number of Days to Update: 50
Source: Napa County Department of Environmental Management Telephone: 707-253-4269
Last EDR Contact: 08/15/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: No Update Planned
UST NAPA: Closed and Operating Underground Storage Tank Sites Underground storage tank sites located in Napa county.
Date of Government Version: 09/05/2019
Date Data Arrived at EDR: 09/09/2019
Date Made Active in Reports: 10/31/2019
Number of Days to Update: 52
Source: Napa County Department of Environmental Management Telephone: 707-253-4269
Last EDR Contact: 08/15/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: No Update Planned
NEVADA COUNTY:
CUPA NEVADA: CUPA Facility List
CUPA facility list.
Date of Government Version: 07/21/2023
Date Data Arrived at EDR: 07/25/2023
Date Made Active in Reports: 10/11/2023
Number of Days to Update: 78
Source: Community Development Agency
Telephone: 530-265-1467
Last EDR Contact: 10/20/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Varies
ORANGE COUNTY:
IND_SITE ORANGE: List of Industrial Site Cleanups
Petroleum and non-petroleum spills.
TC7493604.2s Page GR-49
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 05/15/2023
Date Data Arrived at EDR: 07/31/2023
Date Made Active in Reports: 08/09/2023
Number of Days to Update: 9
Source: Health Care Agency
Telephone: 714-834-3446
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Annually
LUST ORANGE: List of Underground Storage Tank Cleanups
Orange County Underground Storage Tank Cleanups (LUST).
Date of Government Version: 05/15/2023
Date Data Arrived at EDR: 07/31/2023
Date Made Active in Reports: 08/09/2023
Number of Days to Update: 9
Source: Health Care Agency
Telephone: 714-834-3446
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Quarterly
UST ORANGE: List of Underground Storage Tank Facilities Orange County Underground Storage Tank Facilities (UST).
Date of Government Version: 04/01/2023
Date Data Arrived at EDR: 05/18/2023
Date Made Active in Reports: 06/14/2023
Number of Days to Update: 27
Source: Health Care Agency
Telephone: 714-834-3446
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Quarterly
PLACER COUNTY:
MS PLACER: Master List of Facilities
List includes aboveground tanks, underground tanks and cleanup sites.
Date of Government Version: 08/26/2022
Date Data Arrived at EDR: 08/29/2022
Date Made Active in Reports: 11/15/2022
Number of Days to Update: 78
Source: Placer County Health and Human Services
Telephone: 530-745-2363
Last EDR Contact: 11/01/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Semi-Annually
PLUMAS COUNTY:
CUPA PLUMAS: CUPA Facility List
Plumas County CUPA Program facilities.
Date of Government Version: 03/31/2019
Date Data Arrived at EDR: 04/23/2019
Date Made Active in Reports: 06/26/2019
Number of Days to Update: 64
Source: Plumas County Environmental Health
Telephone: 530-283-6355
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
RIVERSIDE COUNTY:
LUST RIVERSIDE: Listing of Underground Tank Cleanup Sites Riverside County Underground Storage Tank Cleanup Sites (LUST).
Date of Government Version: 07/10/2023
Date Data Arrived at EDR: 07/11/2023
Date Made Active in Reports: 09/26/2023
Number of Days to Update: 77
Source: Department of Environmental Health
Telephone: 951-358-5055
Last EDR Contact: 09/07/2023
Next Scheduled EDR Contact: 12/25/2023
Data Release Frequency: Quarterly
TC7493604.2s Page GR-50
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
UST RIVERSIDE: Underground Storage Tank Tank List
Underground storage tank sites located in Riverside county.
Date of Government Version: 07/10/2023
Date Data Arrived at EDR: 07/11/2023
Date Made Active in Reports: 09/26/2023
Number of Days to Update: 77
Source: Department of Environmental Health
Telephone: 951-358-5055
Last EDR Contact: 09/07/2023
Next Scheduled EDR Contact: 12/25/2023
Data Release Frequency: Quarterly
SACRAMENTO COUNTY:
CS SACRAMENTO: Toxic Site Clean-Up List
List of sites where unauthorized releases of potentially hazardous materials have occurred.
Date of Government Version: 11/07/2022
Date Data Arrived at EDR: 12/21/2022
Date Made Active in Reports: 03/16/2023
Number of Days to Update: 85
Source: Sacramento County Environmental Management
Telephone: 916-875-8406
Last EDR Contact: 09/25/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Quarterly
ML SACRAMENTO: Master Hazardous Materials Facility List Any business that has hazardous materials on site - hazardous material storage sites, underground storage tanks, waste generators.
Date of Government Version: 11/07/2022
Date Data Arrived at EDR: 12/09/2022
Date Made Active in Reports: 03/01/2023
Number of Days to Update: 82
Source: Sacramento County Environmental Management
Telephone: 916-875-8406
Last EDR Contact: 09/25/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Quarterly
SAN BENITO COUNTY:
CUPA SAN BENITO: CUPA Facility List
Cupa facility list
Date of Government Version: 05/02/2023
Date Data Arrived at EDR: 05/04/2023
Date Made Active in Reports: 07/25/2023
Number of Days to Update: 82
Source: San Benito County Environmental Health
Telephone: N/A
Last EDR Contact: 10/18/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
SAN BERNARDINO COUNTY:
PERMITS SAN BERNARDINO: Hazardous Material Permits
This listing includes underground storage tanks, medical waste handlers/generators, hazardous materials handlers, hazardous waste generators, and waste oil generators/handlers.
Date of Government Version: 08/15/2023
Date Data Arrived at EDR: 08/16/2023
Date Made Active in Reports: 11/01/2023
Number of Days to Update: 77
Source: San Bernardino County Fire Department Hazardous Materials Division Telephone: 909-387-3041
Last EDR Contact: 10/26/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Quarterly
SAN DIEGO COUNTY:
TC7493604.2s Page GR-51
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
HMMD SAN DIEGO: Hazardous Materials Management Division Database The database includes: HE58 - This report contains the business name, site address, business phone number, establishment ’H’ permit number, type of permit, and the business status. HE17 - In addition to providing the same information provided in the HE58 listing, HE17 provides inspection dates, violations received by the establishment, hazardous waste generated, the quantity, method of storage, treatment/disposal of waste and the hauler, and information on underground storage tanks. Unauthorized Release List - Includes a summary of environmental contamination cases in San Diego County (underground tank cases, non-tank cases, groundwater contamination, and soil contamination are included.)
Date of Government Version: 05/25/2023
Date Data Arrived at EDR: 05/25/2023
Date Made Active in Reports: 08/16/2023
Number of Days to Update: 83
Source: Hazardous Materials Management Division
Telephone: 619-338-2268
Last EDR Contact: 08/29/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Quarterly
LF SAN DIEGO: Solid Waste Facilities
San Diego County Solid Waste Facilities.
Date of Government Version: 04/04/2023
Date Data Arrived at EDR: 04/05/2023
Date Made Active in Reports: 06/27/2023
Number of Days to Update: 83
Source: Department of Health Services
Telephone: 619-338-2209
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
SAN DIEGO CO LOP: Local Oversight Program Listing
A listing of all LOP release sites that are or were under the County of San Diego’s jurisdiction. Included are closed or transferred cases, open cases, and cases that did not have a case type indicated. The cases without a case type are mostly complaints; however, some of them could be LOP cases.
Date of Government Version: 07/22/2021
Date Data Arrived at EDR: 10/19/2021
Date Made Active in Reports: 01/13/2022
Number of Days to Update: 86
Source: Department of Environmental Health
Telephone: 858-505-6874
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
SAN DIEGO CO SAM: Environmental Case Listing
The listing contains all underground tank release cases and projects pertaining to properties contaminated with hazardous substances that are actively under review by the Site Assessment and Mitigation Program.
Date of Government Version: 03/23/2010
Date Data Arrived at EDR: 06/15/2010
Date Made Active in Reports: 07/09/2010
Number of Days to Update: 24
Source: San Diego County Department of Environmental Health Telephone: 619-338-2371
Last EDR Contact: 08/22/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: No Update Planned
SAN FRANCISCO COUNTY:
CUPA SAN FRANCISCO CO: CUPA Facility Listing
Cupa facilities
Date of Government Version: 08/04/2023
Date Data Arrived at EDR: 08/08/2023
Date Made Active in Reports: 10/26/2023
Number of Days to Update: 79
Source: San Francisco County Department of Environmental Health Telephone: 415-252-3896
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
LUST SAN FRANCISCO: Local Oversite Facilities
A listing of leaking underground storage tank sites located in San Francisco county.
TC7493604.2s Page GR-52
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
Date of Government Version: 09/19/2008
Date Data Arrived at EDR: 09/19/2008
Date Made Active in Reports: 09/29/2008
Number of Days to Update: 10
Source: Department Of Public Health San Francisco County Telephone: 415-252-3920
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: No Update Planned
UST SAN FRANCISCO: Underground Storage Tank Information Underground storage tank sites located in San Francisco county.
Date of Government Version: 08/04/2023
Date Data Arrived at EDR: 08/08/2023
Date Made Active in Reports: 10/25/2023
Number of Days to Update: 78
Source: Department of Public Health
Telephone: 415-252-3920
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Quarterly
SAN FRANCISO COUNTY:
SAN FRANCISCO MAHER: Maher Ordinance Property Listing
a listing of properties that fall within a Maher Ordinance, for all of San Francisco Date of Government Version: 07/17/2023
Date Data Arrived at EDR: 07/18/2023
Date Made Active in Reports: 10/05/2023
Number of Days to Update: 79
Source: San Francisco Planning
Telephone: 628-652-7483
Last EDR Contact: 10/17/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
SAN JOAQUIN COUNTY:
UST SAN JOAQUIN: San Joaquin Co. UST
A listing of underground storage tank locations in San Joaquin county.
Date of Government Version: 06/22/2018
Date Data Arrived at EDR: 06/26/2018
Date Made Active in Reports: 07/11/2018
Number of Days to Update: 15
Source: Environmental Health Department
Telephone: N/A
Last EDR Contact: 09/07/2023
Next Scheduled EDR Contact: 12/25/2023
Data Release Frequency: Semi-Annually
SAN LUIS OBISPO COUNTY:
CUPA SAN LUIS OBISPO: CUPA Facility List
Cupa Facility List.
Date of Government Version: 08/09/2023
Date Data Arrived at EDR: 08/10/2023
Date Made Active in Reports: 10/27/2023
Number of Days to Update: 78
Source: San Luis Obispo County Public Health Department Telephone: 805-781-5596
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/26/2024
Data Release Frequency: Varies
SAN MATEO COUNTY:
BI SAN MATEO: Business Inventory
List includes Hazardous Materials Business Plan, hazardous waste generators, and underground storage tanks.
Date of Government Version: 02/20/2020
Date Data Arrived at EDR: 02/20/2020
Date Made Active in Reports: 04/24/2020
Number of Days to Update: 64
Source: San Mateo County Environmental Health Services Division Telephone: 650-363-1921
Last EDR Contact: 09/08/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Annually
TC7493604.2s Page GR-53
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
LUST SAN MATEO: Fuel Leak List
A listing of leaking underground storage tank sites located in San Mateo county.
Date of Government Version: 03/29/2019
Date Data Arrived at EDR: 03/29/2019
Date Made Active in Reports: 05/29/2019
Number of Days to Update: 61
Source: San Mateo County Environmental Health Services Division Telephone: 650-363-1921
Last EDR Contact: 08/29/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Semi-Annually
SANTA BARBARA COUNTY:
CUPA SANTA BARBARA: CUPA Facility Listing
CUPA Program Listing from the Environmental Health Services division.
Date of Government Version: 09/08/2011
Date Data Arrived at EDR: 09/09/2011
Date Made Active in Reports: 10/07/2011
Number of Days to Update: 28
Source: Santa Barbara County Public Health Department
Telephone: 805-686-8167
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/26/2024
Data Release Frequency: No Update Planned
SANTA CLARA COUNTY:
CUPA SANTA CLARA: Cupa Facility List
Cupa facility list
Date of Government Version: 05/10/2023
Date Data Arrived at EDR: 05/11/2023
Date Made Active in Reports: 07/31/2023
Number of Days to Update: 81
Source: Department of Environmental Health
Telephone: 408-918-1973
Last EDR Contact: 10/31/2023
Next Scheduled EDR Contact: 02/26/2024
Data Release Frequency: Varies
HIST LUST SANTA CLARA: HIST LUST - Fuel Leak Site Activity Report A listing of open and closed leaking underground storage tanks. This listing is no longer updated by the county.
Leaking underground storage tanks are now handled by the Department of Environmental Health.
Date of Government Version: 03/29/2005
Date Data Arrived at EDR: 03/30/2005
Date Made Active in Reports: 04/21/2005
Number of Days to Update: 22
Source: Santa Clara Valley Water District
Telephone: 408-265-2600
Last EDR Contact: 03/23/2009
Next Scheduled EDR Contact: 06/22/2009
Data Release Frequency: No Update Planned
LUST SANTA CLARA: LOP Listing
A listing of leaking underground storage tanks located in Santa Clara county.
Date of Government Version: 03/03/2014
Date Data Arrived at EDR: 03/05/2014
Date Made Active in Reports: 03/18/2014
Number of Days to Update: 13
Source: Department of Environmental Health
Telephone: 408-918-3417
Last EDR Contact: 08/15/2023
Next Scheduled EDR Contact: 12/04/2023
Data Release Frequency: No Update Planned
SANTA CRUZ COUNTY:
CUPA SANTA CRUZ: CUPA Facility List
CUPA facility listing.
Date of Government Version: 01/21/2017
Date Data Arrived at EDR: 02/22/2017
Date Made Active in Reports: 05/23/2017
Number of Days to Update: 90
Source: Santa Cruz County Environmental Health
Telephone: 831-464-2761
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/26/2024
Data Release Frequency: Varies
SHASTA COUNTY:
TC7493604.2s Page GR-54
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
CUPA SHASTA: CUPA Facility List
Cupa Facility List.
Date of Government Version: 06/15/2017
Date Data Arrived at EDR: 06/19/2017
Date Made Active in Reports: 08/09/2017
Number of Days to Update: 51
Source: Shasta County Department of Resource Management Telephone: 530-225-5789
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/26/2024
Data Release Frequency: Varies
SOLANO COUNTY:
LUST SOLANO: Leaking Underground Storage Tanks
A listing of leaking underground storage tank sites located in Solano county.
Date of Government Version: 06/04/2019
Date Data Arrived at EDR: 06/06/2019
Date Made Active in Reports: 08/13/2019
Number of Days to Update: 68
Source: Solano County Department of Environmental Management Telephone: 707-784-6770
Last EDR Contact: 08/22/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Quarterly
UST SOLANO: Underground Storage Tanks
Underground storage tank sites located in Solano county.
Date of Government Version: 09/15/2021
Date Data Arrived at EDR: 09/16/2021
Date Made Active in Reports: 12/09/2021
Number of Days to Update: 84
Source: Solano County Department of Environmental Management Telephone: 707-784-6770
Last EDR Contact: 08/22/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Quarterly
SONOMA COUNTY:
CUPA SONOMA: Cupa Facility List
Cupa Facility list
Date of Government Version: 07/02/2021
Date Data Arrived at EDR: 07/06/2021
Date Made Active in Reports: 07/14/2021
Number of Days to Update: 8
Source: County of Sonoma Fire & Emergency Services Department Telephone: 707-565-1174
Last EDR Contact: 09/12/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Varies
LUST SONOMA: Leaking Underground Storage Tank Sites
A listing of leaking underground storage tank sites located in Sonoma county.
Date of Government Version: 06/30/2021
Date Data Arrived at EDR: 06/30/2021
Date Made Active in Reports: 09/24/2021
Number of Days to Update: 86
Source: Department of Health Services
Telephone: 707-565-6565
Last EDR Contact: 09/12/2023
Next Scheduled EDR Contact: 01/01/2024
Data Release Frequency: Quarterly
STANISLAUS COUNTY:
CUPA STANISLAUS: CUPA Facility List
Cupa facility list
Date of Government Version: 02/08/2022
Date Data Arrived at EDR: 02/10/2022
Date Made Active in Reports: 05/04/2022
Number of Days to Update: 83
Source: Stanislaus County Department of Ennvironmental Protection Telephone: 209-525-6751
Last EDR Contact: 10/04/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: Varies
SUTTER COUNTY:
TC7493604.2s Page GR-55
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
UST SUTTER: Underground Storage Tanks
Underground storage tank sites located in Sutter county.
Date of Government Version: 08/03/2023
Date Data Arrived at EDR: 08/24/2023
Date Made Active in Reports: 09/12/2023
Number of Days to Update: 19
Source: Sutter County Environmental Health Services
Telephone: 530-822-7500
Last EDR Contact: 08/22/2023
Next Scheduled EDR Contact: 12/11/2023
Data Release Frequency: Semi-Annually
TEHAMA COUNTY:
CUPA TEHAMA: CUPA Facility List
Cupa facilities
Date of Government Version: 08/01/2023
Date Data Arrived at EDR: 08/02/2023
Date Made Active in Reports: 10/19/2023
Number of Days to Update: 78
Source: Tehama County Department of Environmental Health Telephone: 530-527-8020
Last EDR Contact: 11/08/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
TRINITY COUNTY:
CUPA TRINITY: CUPA Facility List
Cupa facility list
Date of Government Version: 07/11/2023
Date Data Arrived at EDR: 07/12/2023
Date Made Active in Reports: 09/26/2023
Number of Days to Update: 76
Source: Department of Toxic Substances Control
Telephone: 760-352-0381
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
TULARE COUNTY:
CUPA TULARE: CUPA Facility List
Cupa program facilities
Date of Government Version: 10/07/2022
Date Data Arrived at EDR: 10/07/2022
Date Made Active in Reports: 12/21/2022
Number of Days to Update: 75
Source: Tulare County Environmental Health Services Division Telephone: 559-624-7400
Last EDR Contact: 10/25/2023
Next Scheduled EDR Contact: 02/12/2024
Data Release Frequency: Varies
TUOLUMNE COUNTY:
CUPA TUOLUMNE: CUPA Facility List
Cupa facility list
Date of Government Version: 04/23/2018
Date Data Arrived at EDR: 04/25/2018
Date Made Active in Reports: 06/25/2018
Number of Days to Update: 61
Source: Divison of Environmental Health
Telephone: 209-533-5633
Last EDR Contact: 10/10/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Varies
VENTURA COUNTY:
TC7493604.2s Page GR-56
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
BWT VENTURA: Business Plan, Hazardous Waste Producers, and Operating Underground Tanks The BWT list indicates by site address whether the Environmental Health Division has Business Plan (B), Waste Producer (W), and/or Underground Tank (T) information.
Date of Government Version: 06/26/2023
Date Data Arrived at EDR: 07/20/2023
Date Made Active in Reports: 10/03/2023
Number of Days to Update: 75
Source: Ventura County Environmental Health Division
Telephone: 805-654-2813
Last EDR Contact: 10/16/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Quarterly
LF VENTURA: Inventory of Illegal Abandoned and Inactive Sites Ventura County Inventory of Closed, Illegal Abandoned, and Inactive Sites.
Date of Government Version: 12/01/2011
Date Data Arrived at EDR: 12/01/2011
Date Made Active in Reports: 01/19/2012
Number of Days to Update: 49
Source: Environmental Health Division
Telephone: 805-654-2813
Last EDR Contact: 09/21/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: No Update Planned
LUST VENTURA: Listing of Underground Tank Cleanup Sites Ventura County Underground Storage Tank Cleanup Sites (LUST).
Date of Government Version: 05/29/2008
Date Data Arrived at EDR: 06/24/2008
Date Made Active in Reports: 07/31/2008
Number of Days to Update: 37
Source: Environmental Health Division
Telephone: 805-654-2813
Last EDR Contact: 11/02/2023
Next Scheduled EDR Contact: 02/19/2024
Data Release Frequency: No Update Planned
MED WASTE VENTURA: Medical Waste Program List
To protect public health and safety and the environment from potential exposure to disease causing agents, the Environmental Health Division Medical Waste Program regulates the generation, handling, storage, treatment and disposal of medical waste throughout the County.
Date of Government Version: 06/26/2023
Date Data Arrived at EDR: 07/25/2023
Date Made Active in Reports: 10/13/2023
Number of Days to Update: 80
Source: Ventura County Resource Management Agency
Telephone: 805-654-2813
Last EDR Contact: 10/16/2023
Next Scheduled EDR Contact: 01/29/2024
Data Release Frequency: Quarterly
UST VENTURA: Underground Tank Closed Sites List
Ventura County Operating Underground Storage Tank Sites (UST)/Underground Tank Closed Sites List.
Date of Government Version: 05/26/2023
Date Data Arrived at EDR: 06/02/2023
Date Made Active in Reports: 06/14/2023
Number of Days to Update: 12
Source: Environmental Health Division
Telephone: 805-654-2813
Last EDR Contact: 09/06/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Quarterly
YOLO COUNTY:
UST YOLO: Underground Storage Tank Comprehensive Facility Report Underground storage tank sites located in Yolo county.
Date of Government Version: 04/03/2023
Date Data Arrived at EDR: 04/18/2023
Date Made Active in Reports: 06/13/2023
Number of Days to Update: 56
Source: Yolo County Department of Health
Telephone: 530-666-8646
Last EDR Contact: 09/21/2023
Next Scheduled EDR Contact: 01/08/2024
Data Release Frequency: Annually
YUBA COUNTY:
TC7493604.2s Page GR-57
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
CUPA YUBA: CUPA Facility List
CUPA facility listing for Yuba County.
Date of Government Version: 07/24/2023
Date Data Arrived at EDR: 07/26/2023
Date Made Active in Reports: 10/11/2023
Number of Days to Update: 77
Source: Yuba County Environmental Health Department
Telephone: 530-749-7523
Last EDR Contact: 10/20/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Varies
OTHER DATABASE(S)
Depending on the geographic area covered by this report, the data provided in these specialty databases may or may not be complete. For example, the existence of wetlands information data in a specific report does not mean that all wetlands in the area covered by the report are included. Moreover, the absence of any reported wetlands information does not necessarily mean that wetlands do not exist in the area covered by the report.
CT MANIFEST: Hazardous Waste Manifest Data
Facility and manifest data. Manifest is a document that lists and tracks hazardous waste from the generator through transporters to a tsd facility.
Date of Government Version: 08/07/2023
Date Data Arrived at EDR: 08/08/2023
Date Made Active in Reports: 10/24/2023
Number of Days to Update: 77
Source: Department of Energy & Environmental Protection Telephone: 860-424-3375
Last EDR Contact: 11/07/2023
Next Scheduled EDR Contact: 02/19/2024
Data Release Frequency: No Update Planned
NJ MANIFEST: Manifest Information
Hazardous waste manifest information.
Date of Government Version: 12/31/2018
Date Data Arrived at EDR: 04/10/2019
Date Made Active in Reports: 05/16/2019
Number of Days to Update: 36
Source: Department of Environmental Protection
Telephone: N/A
Last EDR Contact: 09/28/2023
Next Scheduled EDR Contact: 01/15/2024
Data Release Frequency: Annually
NY MANIFEST: Facility and Manifest Data
Manifest is a document that lists and tracks hazardous waste from the generator through transporters to a TSD facility.
Date of Government Version: 01/01/2019
Date Data Arrived at EDR: 10/29/2021
Date Made Active in Reports: 01/19/2022
Number of Days to Update: 82
Source: Department of Environmental Conservation
Telephone: 518-402-8651
Last EDR Contact: 10/28/2023
Next Scheduled EDR Contact: 02/05/2024
Data Release Frequency: Quarterly
PA MANIFEST: Manifest Information
Hazardous waste manifest information.
Date of Government Version: 06/30/2018
Date Data Arrived at EDR: 07/19/2019
Date Made Active in Reports: 09/10/2019
Number of Days to Update: 53
Source: Department of Environmental Protection
Telephone: 717-783-8990
Last EDR Contact: 10/05/2023
Next Scheduled EDR Contact: 01/22/2024
Data Release Frequency: Annually
RI MANIFEST: Manifest information
Hazardous waste manifest information
Date of Government Version: 12/31/2020
Date Data Arrived at EDR: 11/30/2021
Date Made Active in Reports: 02/18/2022
Number of Days to Update: 80
Source: Department of Environmental Management
Telephone: 401-222-2797
Last EDR Contact: 08/10/2022
Next Scheduled EDR Contact: 11/27/2023
Data Release Frequency: Annually
TC7493604.2s Page GR-58
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
WI MANIFEST: Manifest Information
Hazardous waste manifest information.
Date of Government Version: 05/31/2018
Date Data Arrived at EDR: 06/19/2019
Date Made Active in Reports: 09/03/2019
Number of Days to Update: 76
Source: Department of Natural Resources
Telephone: N/A
Last EDR Contact: 08/30/2023
Next Scheduled EDR Contact: 12/18/2023
Data Release Frequency: Annually
Oil/Gas Pipelines
Source: Endeavor Business Media
Petroleum Bundle (Crude Oil, Refined Products, Petrochemicals, Gas Liquids (LPG/NGL), and Specialty Gases (Miscellaneous)) N = Natural Gas Bundle (Natural Gas, Gas Liquids (LPG/NGL), and Specialty Gases (Miscellaneous)). This map includes information copyrighted by Endeavor Business Media. This information is provided on a best effort basis and Endeavor Business Media does not guarantee its accuracy nor warrant its fitness for any particular purpose. Such information has been reprinted with the permission of Endeavor Business Media.
Electric Power Transmission Line Data
Source: Endeavor Business Media
This map includes information copyrighted by Endeavor Business Media. This information is provided on a best effort basis and Endeavor Business Media does not guarantee its accuracy nor warrant its fitness for any particular purpose. Such information has been reprinted with the permission of Endeavor Business Media.
Sensitive Receptors: There are individuals deemed sensitive receptors due to their fragile immune systems and special sensitivity to environmental discharges. These sensitive receptors typically include the elderly, the sick, and children. While the location of all sensitive receptors cannot be determined, EDR indicates those buildings and facilities - schools, daycares, hospitals, medical centers, and nursing homes - where individuals who are sensitive receptors are likely to be located.
AHA Hospitals:
Source: American Hospital Association, Inc.
Telephone: 312-280-5991
The database includes a listing of hospitals based on the American Hospital Association’s annual survey of hospitals.
Medical Centers: Provider of Services Listing
Source: Centers for Medicare & Medicaid Services
Telephone: 410-786-3000
A listing of hospitals with Medicare provider number, produced by Centers of Medicare & Medicaid Services, a federal agency within the U.S. Department of Health and Human Services.
Nursing Homes
Source: National Institutes of Health
Telephone: 301-594-6248
Information on Medicare and Medicaid certified nursing homes in the United States.
Public Schools
Source: National Center for Education Statistics
Telephone: 202-502-7300
The National Center for Education Statistics’ primary database on elementary and secondary public education in the United States. It is a comprehensive, annual, national statistical database of all public elementary and secondary schools and school districts, which contains data that are comparable across all states.
Private Schools
Source: National Center for Education Statistics
Telephone: 202-502-7300
The National Center for Education Statistics’ primary database on private school locations in the United States.
Daycare Centers: Licensed Facilities
Source: Department of Social Services
Telephone: 916-657-4041
Flood Zone Data: This data was obtained from the Federal Emergency Management Agency (FEMA). It depicts 100-year and 500-year flood zones as defined by FEMA. It includes the National Flood Hazard Layer (NFHL) which incorporates Flood Insurance Rate Map (FIRM) data and Q3 data from FEMA in areas not covered by NFHL.
Source: FEMA
Telephone: 877-336-2627
Date of Government Version: 2003, 2015
TC7493604.2s Page GR-59
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
NWI: National Wetlands Inventory. This data, available in select counties across the country, was obtained by EDR in 2002, 2005, 2010 and 2015 from the U.S. Fish and Wildlife Service.
State Wetlands Data: Wetland Inventory
Source: Department of Fish and Wildlife
Telephone: 916-445-0411
Current USGS 7.5 Minute Topographic Map
Source: U.S. Geological Survey
STREET AND ADDRESS INFORMATION
© 2015 TomTom North America, Inc. All rights reserved. This material is proprietary and the subject of copyright protection and other intellectual property rights owned by or licensed to Tele Atlas North America, Inc. The use of this material is subject to the terms of a license agreement. You will be held liable for any unauthorized copying or disclosure of this material.
TC7493604.2s Page GR-60
GOVERNMENT RECORDS SEARCHED / DATA CURRENCY TRACKING
TC7493604.2s Page A-1
geologic strata.
of the soil, and nearby wells. Groundwater flow velocity is generally impacted by the nature of the Groundwater flow direction may be impacted by surface topography, hydrology, hydrogeology, characteristics
2. Groundwater flow velocity.
1. Groundwater flow direction, and
Assessment of the impact of contaminant migration generally has two principle investigative components:
forming an opinion about the impact of potential contaminant migration.
EDR’s GeoCheck Physical Setting Source Addendum is provided to assist the environmental professional in Version Date: 2018
Target Property Map: 12008233 EL CAJON, CA
USGS TOPOGRAPHIC MAP
Elevation: 343 ft. above sea level
UTM Y (Meters): 3634295.5
UTM X (Meters): 502279.8
Universal Tranverse Mercator: Zone 11
Longitude (West): 116.975637 - 116˚ 58’ 32.29’’
Latitude (North): 32.848446 - 32˚ 50’ 54.41’’
TARGET PROPERTY COORDINATES
SANTEE, CA 92071
NOT REPORTED
NOT REPORTED
TARGET PROPERTY ADDRESS
GEOCHECK - PHYSICAL SETTING SOURCE ADDENDUM ®
TC7493604.2s Page A-2
should be field verified.
on a relative (not an absolute) basis. Relative elevation information between sites of close proximity Source: Topography has been determined from the USGS 7.5’ Digital Elevation Model and should be evaluated SURROUNDING TOPOGRAPHY: ELEVATION PROFILES Elevation (ft) Elevation (ft) TP
TP
0 1/2 1 Miles ✩Target Property Elevation: 343 ft.
North South
West East 360 353 350 343 341 341 343 347 350 350 350 350 353 386 376 371 403 424 421 371 348 342 340 337 340 343 343 343 343 347 347 353 350 340 353 353 356 356 General Topographic Gradient: General SSW
TARGET PROPERTY TOPOGRAPHY
should contamination exist on the target property, what downgradient sites might be impacted. assist the environmental professional in forming an opinion about the impact of nearby contaminated properties or, Surface topography may be indicative of the direction of surficial groundwater flow. This information can be used to
TOPOGRAPHIC INFORMATION
collected on nearby properties, and regional groundwater flow information (from deep aquifers). sources of information, such as surface topographic information, hydrologic information, hydrogeologic data using site-specific well data. If such data is not reasonably ascertainable, it may be necessary to rely on other Groundwater flow direction for a particular site is best determined by a qualified environmental professional
GROUNDWATER FLOW DIRECTION INFORMATION
GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
TC7493604.2s Page A-3
For additional site information, refer to Physical Setting Source Map Findings. 3G 1/2 - 1 Mile SSW Varies
2G 1/2 - 1 Mile SW Not Reported
1G 1/2 - 1 Mile SW NNW
M124 1/2 - 1 Mile SW NNW
K86 1/2 - 1 Mile SW Not Reported
69 1/2 - 1 Mile SSW Varies
LOCATION GENERAL DIRECTION
MAP ID FROM TP GROUNDWATER FLOW
hydrogeologically, and the depth to water table.
authorities at select sites and has extracted the date of the report, groundwater flow direction as determined flow at specific points. EDR has reviewed reports submitted by environmental professionals to regulatory EDR has developed the AQUIFLOW Information System to provide data on the general direction of groundwater AQUIFLOW®
Search Radius: 1.000 Mile.
Status: Not found
Search Radius: 1.25 miles
Site-Specific Hydrogeological Data*:
* ©1996 Site−specific hydrogeological data gathered by CERCLIS Alerts, Inc., Bainbridge Island, WA. All rights reserved. All of the information and opinions presented are those of the cited EPA report(s), which were completed under a Comprehensive Environmental Response Compensation and Liability Information System (CERCLIS) investigation. contamination exist on the target property, what downgradient sites might be impacted. environmental professional in forming an opinion about the impact of nearby contaminated properties or, should of groundwater flow direction in the immediate area. Such hydrogeologic information can be used to assist the Hydrogeologic information obtained by installation of wells on a specific site can often be an indicator
HYDROGEOLOGIC INFORMATION
EL CAJON YES - refer to the Overview Map and Detail Map
NATIONAL WETLAND INVENTORY
NWI Electronic
NWI Quad at Target Property Data Coverage
06073C1654G FEMA FIRM Flood data
06073C1653G FEMA FIRM Flood data
06073C1652G FEMA FIRM Flood data
Additional Panels in search area: FEMA Source Type
06073C1651G FEMA FIRM Flood data
Flood Plain Panel at Target Property FEMA Source Type
FEMA FLOOD ZONE
and bodies of water).
Refer to the Physical Setting Source Map following this summary for hydrologic information (major waterways contamination exist on the target property, what downgradient sites might be impacted. the environmental professional in forming an opinion about the impact of nearby contaminated properties or, should Surface water can act as a hydrologic barrier to groundwater flow. Such hydrologic information can be used to assist
HYDROLOGIC INFORMATION
GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
TC7493604.2s Page A-4
Map, USGS Digital Data Series DDS - 11 (1994).
of the Conterminous U.S. at 1:2,500,000 Scale - a digital representation of the 1974 P.B. King and H.M. Beikman Geologic Age and Rock Stratigraphic Unit Source: P.G. Schruben, R.E. Arndt and W.J. Bawiec, Geology
ROCK STRATIGRAPHIC UNIT GEOLOGIC AGE IDENTIFICATION
Era: Mesozoic Category: Plutonic and Intrusive Rocks
System: Cretaceous
Series: Cretaceous granitic rocks
Code: Kg (decoded above as Era, System & Series)
at which contaminant migration may be occurring.
Geologic information can be used by the environmental professional in forming an opinion about the relative speed
GEOLOGIC INFORMATION IN GENERAL AREA OF TARGET PROPERTY move more quickly through sandy-gravelly types of soils than silty-clayey types of soils. characteristics data collected on nearby properties and regional soil information. In general, contaminant plumes to rely on other sources of information, including geologic age identification, rock stratigraphic unit and soil using site specific geologic and soil strata data. If such data are not reasonably ascertainable, it may be necessary Groundwater flow velocity information for a particular site is best determined by a qualified environmental professional
GROUNDWATER FLOW VELOCITY INFORMATION
GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc. 4 6
5 1
2 3
5 0 1/16 1/8 1/4 Miles
TC7493604.2s Page A-6
Min: 6.6
Max: 7.8
Min: 42
Max: 141
Silty Sand.
Sands with fines,
SOILS, Sands,
COARSE-GRAINED
Well-graded sand.
Clean Sands,
SOILS, Sands,
COARSE-GRAINED
Sand.
Gravel and
Fragments,
200), Stone
passing No.
pct. or less
materials (35
Granular
loamy sand
to gravelly
gravelly sand
3 33 inches 59 inches stratified
Min: 6.6
Max: 7.8
Min: 42
Max: 141
Silty Sand.
Sands with fines,
SOILS, Sands,
COARSE-GRAINED
Well-graded sand.
Clean Sands,
SOILS, Sands,
COARSE-GRAINED
Sand.
Gravel and
Fragments,
200), Stone
passing No.
pct. or less
materials (35
2 14 inches 33 inches loamy sand Granular
Min: 6.6
Max: 7.8
Min: 42
Max: 141
Silty Sand.
Sands with fines,
SOILS, Sands,
COARSE-GRAINED
Well-graded sand.
Clean Sands,
SOILS, Sands,
COARSE-GRAINED
Sand.
Gravel and
Fragments,
200), Stone
passing No.
pct. or less
materials (35
1 0 inches 14 inches sand Granular
Soil Layer Information
Boundary Classification Saturated
hydraulic
conductivity
micro m/sec Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil Soil Reaction (pH)
Depth to Watertable Min: > 0 inches
Depth to Bedrock Min: > 0 inches
Corrosion Potential - Uncoated Steel: Moderate
Hydric Status: Partially hydric
Soil Drainage Class: Somewhat excessively drained
excessively drained sands and gravels.
Hydrologic Group: Class A - High infiltration rates. Soils are deep, well drained to Soil Surface Texture: sand
Soil Component Name: TUJUNGA
Soil Map ID: 1
in a landscape. The following information is based on Soil Conservation Service SSURGO data. for privately owned lands in the United States. A soil map in a soil survey is a representation of soil patterns Survey (NCSS) and is responsible for collecting, storing, maintaining and distributing soil survey information The U.S. Department of Agriculture’s (USDA) Soil Conservation Service (SCS) leads the National Cooperative Soil
DOMINANT SOIL COMPOSITION IN GENERAL AREA OF TARGET PROPERTY GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
TC7493604.2s Page A-7
Soil Drainage Class:
water table, or are shallow to an impervious layer.
Hydrologic Group: Class D - Very slow infiltration rates. Soils are clayey, have a high Soil Surface Texture: gravelly coarse sand
Soil Component Name: Water
Soil Map ID: 3
Max: Min:
Min: 42
Max: 141
gravel.
Well-graded
Clean Gravels,
SOILIS, Gravels,
COARSE-GRAINED
Sand.
Gravel and
Fragments,
200), Stone
passing No.
pct. or less
materials (35
Granular
gravelly sand
sand to
gravelly coarse
extremely
2 5 inches 59 inches stratified
Max: Min:
Min: 42
Max: 141
gravel.
Well-graded
Clean Gravels,
SOILIS, Gravels,
COARSE-GRAINED
Sand.
Gravel and
Fragments,
200), Stone
passing No.
pct. or less
materials (35
Granular
sand
1 0 inches 5 inches gravelly coarse
Soil Layer Information
Boundary Classification Saturated
hydraulic
conductivity
micro m/sec Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil Soil Reaction (pH)
Depth to Watertable Min: > 168 inches
Depth to Bedrock Min: > 0 inches
Corrosion Potential - Uncoated Steel: Not Reported
Hydric Status: All hydric
Soil Drainage Class: Excessively drained
water table, or are shallow to an impervious layer.
Hydrologic Group: Class D - Very slow infiltration rates. Soils are clayey, have a high Soil Surface Texture: gravelly coarse sand
Soil Component Name: RIVERWASH
Soil Map ID: 2
GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
TC7493604.2s Page A-8
Min: 7.9
Max: 8.4
Min: 1.4
Max: 4
50%), Lean Clay
limit less than
Clays (liquid
SOILS, Silts and
FINE-GRAINED
Soils.
200), Clayey
passing No.
than 35 pct.
Materials (more
3 46 inches 64 inches loam Silt-Clay
Min: 7.9
Max: 8.4
Min: 1.4
Max: 4
50%), Lean Clay
limit less than
Clays (liquid
SOILS, Silts and
FINE-GRAINED
Soils.
200), Clayey
passing No.
than 35 pct.
Materials (more
2 22 inches 46 inches clay loam Silt-Clay
Min: 7.9
Max: 8.4
Min: 1.4
Max: 4
50%), Lean Clay
limit less than
Clays (liquid
SOILS, Silts and
FINE-GRAINED
Soils.
200), Clayey
passing No.
than 35 pct.
Materials (more
1 0 inches 22 inches clay Silt-Clay
Soil Layer Information
Boundary Classification Saturated
hydraulic
conductivity
micro m/sec Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil Soil Reaction (pH)
Depth to Watertable Min: > 0 inches
Depth to Bedrock Min: > 0 inches
Corrosion Potential - Uncoated Steel: High
Hydric Status: Not hydric
Soil Drainage Class: Well drained
water table, or are shallow to an impervious layer.
Hydrologic Group: Class D - Very slow infiltration rates. Soils are clayey, have a high Soil Surface Texture: clay
Soil Component Name: SALINAS
Soil Map ID: 4
No Layer Information available.
Depth to Watertable Min: > 0 inches
Depth to Bedrock Min: > 0 inches
Corrosion Potential - Uncoated Steel: Not Reported
Hydric Status: Not hydric
GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
TC7493604.2s Page A-9
Soil Drainage Class: Moderately well drained
water table, or are shallow to an impervious layer.
Hydrologic Group: Class D - Very slow infiltration rates. Soils are clayey, have a high Soil Surface Texture: sandy loam
Soil Component Name: PLACENTIA
Soil Map ID: 6
Min: 6.1
Max: 6.5
Min: 14
Max: 42
50%), silt.
limit less than
Clays (liquid
SOILS, Silts and
FINE-GRAINED
Soils.
200), Silty
passing No.
than 35 pct.
Materials (more
Silt-Clay
loam
3 40 inches 59 inches very fine sandy
Min: 6.1
Max: 6.5
Min: 14
Max: 42
50%), silt.
limit less than
Clays (liquid
SOILS, Silts and
FINE-GRAINED
Soils.
200), Silty
passing No.
than 35 pct.
Materials (more
2 11 inches 40 inches sandy loam Silt-Clay
Min: 6.1
Max: 6.5
Min: 14
Max: 42
50%), silt.
limit less than
Clays (liquid
SOILS, Silts and
FINE-GRAINED
Soils.
200), Silty
passing No.
than 35 pct.
Materials (more
1 0 inches 11 inches sandy loam Silt-Clay
Soil Layer Information
Boundary Classification Saturated
hydraulic
conductivity
micro m/sec Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil Soil Reaction (pH)
Depth to Watertable Min: > 0 inches
Depth to Bedrock Min: > 0 inches
Corrosion Potential - Uncoated Steel: Moderate
Hydric Status: Partially hydric
Soil Drainage Class: Well drained
textures.
moderately well and well drained soils with moderately coarse Hydrologic Group: Class B - Moderate infiltration rates. Deep and moderately deep, Soil Surface Texture: sandy loam
Soil Component Name: VISALIA
Soil Map ID: 5
GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
TC7493604.2s Page A-10
O130 USGS40000129898 1/2 - 1 Mile SSW
H68 USGS40000129937 1/2 - 1 Mile NE
D16 USGS40000129916 1/4 - 1/2 Mile ESE
FEDERAL USGS WELL INFORMATION
LOCATION
MAP ID WELL ID FROM TP
State Database 1.000
Federal FRDS PWS Nearest PWS within 1 mile
Federal USGS 1.000
WELL SEARCH DISTANCE INFORMATION
DATABASE SEARCH DISTANCE (miles)
opinion about the impact of contaminant migration on nearby drinking water wells. professional in assessing sources that may impact ground water flow direction, and in forming an EDR Local/Regional Water Agency records provide water well information to assist the environmental
LOCAL / REGIONAL WATER AGENCY RECORDS
Min: 7.9
Max: 8.4
Min: 0.01
Max: 0.42
50%), Lean Clay
limit less than
Clays (liquid
SOILS, Silts and
FINE-GRAINED
Soils.
200), Silty
passing No.
than 35 pct.
Materials (more
2 12 inches 33 inches clay Silt-Clay
Min: 7.9
Max: 8.4
Min: 0.01
Max: 0.42
50%), Lean Clay
limit less than
Clays (liquid
SOILS, Silts and
FINE-GRAINED
Soils.
200), Silty
passing No.
than 35 pct.
Materials (more
1 0 inches 12 inches sandy loam Silt-Clay
Soil Layer Information
Boundary Classification Saturated
hydraulic
conductivity
micro m/sec Layer Upper Lower Soil Texture Class AASHTO Group Unified Soil Soil Reaction (pH)
Depth to Watertable Min: > 0 inches
Depth to Bedrock Min: > 0 inches
Corrosion Potential - Uncoated Steel: High
Hydric Status: Partially hydric
GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
TC7493604.2s Page A-11
E44 CAEDF0000065356 1/4 - 1/2 Mile NNE
E43 CAEDF0000120681 1/4 - 1/2 Mile NNE
E42 CAEDF0000117944 1/4 - 1/2 Mile NNE
E41 CAEDF0000101025 1/4 - 1/2 Mile NNE
E40 CAEDF0000134270 1/4 - 1/2 Mile NNE
E39 CAEDF0000033499 1/4 - 1/2 Mile NNE
E38 CAEDF0000131320 1/4 - 1/2 Mile NNE
F37 CADWR0000001600 1/4 - 1/2 Mile NE
F36 CADWR0000008714 1/4 - 1/2 Mile NE
E35 CAEDF0000006551 1/4 - 1/2 Mile NNE
C34 CAEDF0000078820 1/4 - 1/2 Mile North
C33 CAEDF0000049766 1/4 - 1/2 Mile North
C32 CAEDF0000138987 1/4 - 1/2 Mile North
C31 CAEDF0000017086 1/4 - 1/2 Mile North
C30 CAEDF0000022075 1/4 - 1/2 Mile North
E29 CAEDF0000093811 1/4 - 1/2 Mile NE
C28 CAEDF0000075043 1/4 - 1/2 Mile North
C27 CAEDF0000103694 1/4 - 1/2 Mile North
C26 CAEDF0000051770 1/4 - 1/2 Mile North
C25 CAEDF0000080398 1/4 - 1/2 Mile North
E24 CAEDF0000106149 1/4 - 1/2 Mile NNE
C23 CAEDF0000046896 1/4 - 1/2 Mile North
C22 CAEDF0000087991 1/4 - 1/2 Mile North
C21 CAEDF0000014109 1/4 - 1/2 Mile North
C20 CAEDF0000003858 1/4 - 1/2 Mile North
D19 CAUSGSN00003066 1/4 - 1/2 Mile ESE
C18 CAEDF0000102879 1/4 - 1/2 Mile North
C17 CAEDF0000100286 1/4 - 1/2 Mile North
C15 CAEDF0000060239 1/4 - 1/2 Mile North
C14 CAEDF0000104776 1/4 - 1/2 Mile North
C13 CAEDF0000070482 1/4 - 1/2 Mile North
B12 CADWR0000018644 1/4 - 1/2 Mile ESE
B11 CADWR0000024386 1/4 - 1/2 Mile ESE
B10 CADWR0000018735 1/4 - 1/2 Mile ESE
A9 CAEDF0000089199 1/8 - 1/4 Mile East
A8 CAEDF0000113145 1/8 - 1/4 Mile East
A7 CAEDF0000031787 1/8 - 1/4 Mile East
A6 CAEDF0000019468 1/8 - 1/4 Mile East
A5 CAEDF0000106144 1/8 - 1/4 Mile East
A4 CAEDF0000060710 1/8 - 1/4 Mile East
A3 CAEDF0000031702 1/8 - 1/4 Mile East
A2 CAEDF0000093974 1/8 - 1/4 Mile East
1 CADWR0000003997 1/8 - 1/4 Mile SSE
STATE DATABASE WELL INFORMATION
LOCATION
MAP ID WELL ID FROM TP
Note: PWS System location is not always the same as well location. 66 CA3710037 1/2 - 1 Mile South
FEDERAL FRDS PUBLIC WATER SUPPLY SYSTEM INFORMATION
LOCATION
MAP ID WELL ID FROM TP
GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
TC7493604.2s Page A-12
J100 CAEDF0000058938 1/2 - 1 Mile SE
K99 CAEDF0000074175 1/2 - 1 Mile SSW
K98 CAEDF0000012435 1/2 - 1 Mile SW
J97 CAEDF0000042666 1/2 - 1 Mile SSE
J96 CAEDF0000084373 1/2 - 1 Mile SSE
K95 CAEDF0000114995 1/2 - 1 Mile SSW
J94 CAEDF0000030745 1/2 - 1 Mile SSE
J93 CAEDF0000115246 1/2 - 1 Mile SSE
K92 CAEDF0000041070 1/2 - 1 Mile SSW
J91 CAEDF0000034301 1/2 - 1 Mile SSE
K90 CAEDF0000009833 1/2 - 1 Mile SW
J89 CAEDF0000131478 1/2 - 1 Mile SSE
K88 CAEDF0000140458 1/2 - 1 Mile SSW
J87 CAEDF0000069424 1/2 - 1 Mile SSE
J85 CAEDF0000114839 1/2 - 1 Mile SSE
J84 CAEDF0000100627 1/2 - 1 Mile SSE
K83 CAEDF0000060472 1/2 - 1 Mile SSW
K82 CAEDF0000102248 1/2 - 1 Mile SSW
J81 CAEDF0000106266 1/2 - 1 Mile SSE
K80 CAEDF0000093837 1/2 - 1 Mile SSW
K79 CAEDF0000099670 1/2 - 1 Mile SSW
J78 CAEDF0000109451 1/2 - 1 Mile SSE
J77 CAEDF0000115243 1/2 - 1 Mile SSE
J76 CAEDF0000092105 1/2 - 1 Mile SSE
75 CADWR0000007719 1/2 - 1 Mile ESE
J74 CAEDF0000060825 1/2 - 1 Mile SSE
I73 CADWR0000023171 1/2 - 1 Mile SSE
I72 CADWR0000026129 1/2 - 1 Mile SSE
I71 CADWR0000014893 1/2 - 1 Mile SSE
I70 CADWR0000019673 1/2 - 1 Mile SSE
H67 CAUSGSN00015577 1/2 - 1 Mile NE
65 CADWR0000002796 1/2 - 1 Mile SE
G64 CAEDF0000123696 1/2 - 1 Mile NW
G63 CAEDF0000075875 1/2 - 1 Mile NW
G62 CAEDF0000111516 1/2 - 1 Mile NW
G61 CAEDF0000079829 1/2 - 1 Mile NW
G60 CAEDF0000013617 1/2 - 1 Mile NW
G59 CAEDF0000048178 1/2 - 1 Mile NW
G58 CAEDF0000057002 1/2 - 1 Mile NW
G57 CAEDF0000136930 1/2 - 1 Mile NW
56 CADWR0000004193 1/2 - 1 Mile NNW
G55 CAEDF0000049461 1/2 - 1 Mile NW
54 CADWR0000007857 1/2 - 1 Mile SE
E53 CAEDF0000021375 1/2 - 1 Mile NNE
E52 CAEDF0000099776 1/2 - 1 Mile NNE
E51 CAEDF0000052018 1/2 - 1 Mile NNE
E50 CAEDF0000083615 1/2 - 1 Mile NNE
E49 CAEDF0000052163 1/2 - 1 Mile NNE
E48 CAEDF0000046659 1/2 - 1 Mile NNE
E47 CAEDF0000116998 1/4 - 1/2 Mile NNE
E46 CAEDF0000100042 1/4 - 1/2 Mile NNE
E45 CAEDF0000120551 1/4 - 1/2 Mile NNE
STATE DATABASE WELL INFORMATION
LOCATION
MAP ID WELL ID FROM TP
GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
TC7493604.2s Page A-13
O132 CAUSGSN00015711 1/2 - 1 Mile SSW
N131 CAEDF0000137743 1/2 - 1 Mile SW
M129 CAEDF0000048880 1/2 - 1 Mile SW
M128 CADWR0000025975 1/2 - 1 Mile SW
N127 CAEDF0000035344 1/2 - 1 Mile SW
N126 CAEDF0000037794 1/2 - 1 Mile SW
M125 CAEDF0000095232 1/2 - 1 Mile SW
L123 CAEDF0000137654 1/2 - 1 Mile SW
M122 CAEDF0000118361 1/2 - 1 Mile SW
L121 CAEDF0000010536 1/2 - 1 Mile SW
L120 CAEDF0000035180 1/2 - 1 Mile SW
L119 CAEDF0000142465 1/2 - 1 Mile SW
L118 CAEDF0000126882 1/2 - 1 Mile SW
M117 CAEDF0000106139 1/2 - 1 Mile SW
L116 CAEDF0000076119 1/2 - 1 Mile SW
L115 CAEDF0000014240 1/2 - 1 Mile SW
114 CADWR0000009465 1/2 - 1 Mile South
113 CAEDF0000050860 1/2 - 1 Mile SSW
J112 CAEDF0000038778 1/2 - 1 Mile SSE
J111 CAEDF0000104365 1/2 - 1 Mile SE
J110 CAEDF0000067998 1/2 - 1 Mile SSE
109 CADWR0000004413 1/2 - 1 Mile SE
J108 CAEDF0000099868 1/2 - 1 Mile SSE
J107 CAEDF0000074976 1/2 - 1 Mile SE
J106 CAEDF0000087777 1/2 - 1 Mile SSE
K105 CAEDF0000059940 1/2 - 1 Mile SW
J104 CAEDF0000107258 1/2 - 1 Mile SSE
J103 CAEDF0000097166 1/2 - 1 Mile SE
J102 CAEDF0000081592 1/2 - 1 Mile SSE
J101 CAEDF0000064558 1/2 - 1 Mile SSE
STATE DATABASE WELL INFORMATION
LOCATION
MAP ID WELL ID FROM TP
GEOCHECK - PHYSICAL SETTING SOURCE SUMMARY ®
EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc.EDR Inc. 8 0 0
400
1 4 0 0
400
400
400
400
600
600
5 0 0
900
500
700
CA
TC7493604.2s Page A-15
gned_name=MW-4
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607399232&assi date=&global_id=T0607399232&assigned_name=MW-4&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-4
Well ID: T0607399232-MW-4 Well Type: MONITORING
A4
East
1/8 - 1/4 Mile
Higher
CA WELLS CAEDF0000060710
gned_name=MW-8
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607399232&assi date=&global_id=T0607399232&assigned_name=MW-8&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-8
Well ID: T0607399232-MW-8 Well Type: MONITORING
A3
East
1/8 - 1/4 Mile
Higher
CA WELLS CAEDF0000031702
gned_name=MW-7
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607399232&assi date=&global_id=T0607399232&assigned_name=MW-7&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-7
Well ID: T0607399232-MW-7 Well Type: MONITORING
A2
East
1/8 - 1/4 Mile
Higher
CA WELLS CAEDF0000093974
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W22P001S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W22P001S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W22P001S Well Type: UNK
1 SSE
1/8 - 1/4 Mile
Higher
CA WELLS CADWR0000003997
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-16
gned_name=MW-5
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607399232&assi date=&global_id=T0607399232&assigned_name=MW-5&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-5
Well ID: T0607399232-MW-5 Well Type: MONITORING
A8
East
1/8 - 1/4 Mile
Higher
CA WELLS CAEDF0000113145
gned_name=MW-6
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607399232&assi date=&global_id=T0607399232&assigned_name=MW-6&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-6
Well ID: T0607399232-MW-6 Well Type: MONITORING
A7
East
1/8 - 1/4 Mile
Higher
CA WELLS CAEDF0000031787
gned_name=MW-1
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607399232&assi date=&global_id=T0607399232&assigned_name=MW-1&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-1
Well ID: T0607399232-MW-1 Well Type: MONITORING
A6
East
1/8 - 1/4 Mile
Higher
CA WELLS CAEDF0000019468
gned_name=MW-3
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607399232&assi date=&global_id=T0607399232&assigned_name=MW-3&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-3
Well ID: T0607399232-MW-3 Well Type: MONITORING
A5
East
1/8 - 1/4 Mile
Higher
CA WELLS CAEDF0000106144
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-17
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W22Q001S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W22Q001S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W22Q001S Well Type: UNK
B12
ESE
1/4 - 1/2 Mile
Higher
CA WELLS CADWR0000018644
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W22Q003S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W22Q003S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W22Q003S Well Type: UNK
B11
ESE
1/4 - 1/2 Mile
Higher
CA WELLS CADWR0000024386
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W22Q002S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W22Q002S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W22Q002S Well Type: UNK
B10
ESE
1/4 - 1/2 Mile
Higher
CA WELLS CADWR0000018735
gned_name=MW-2
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607399232&assi date=&global_id=T0607399232&assigned_name=MW-2&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-2
Well ID: T0607399232-MW-2 Well Type: MONITORING
A9
East
1/8 - 1/4 Mile
Higher
CA WELLS CAEDF0000089199
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-18
Well Depth Units: Not Reported Well Hole Depth: Not Reported Construction Date: Not Reported Well Depth: Not Reported Formation Type: Not Reported Aquifer Type: Not Reported Aquifer: California Coastal Basin aquifers
Contrib Drainage Area: Not Reported Contrib Drainage Area Unts: Not Reported Drainage Area: Not Reported Drainage Area Units: Not Reported Description: Not Reported HUC: 18070304
Monitor Location: 015S001W22Q005S Type: Well
Organization Name: USGS California Water Science Center Organization ID: USGS-CA
D16
ESE
1/4 - 1/2 Mile
Higher
FED USGS USGS40000129916
gned_name=MW-18
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-18&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-18
Well ID: T0607302618-MW-18 Well Type: MONITORING
C15
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000060239
gned_name=MW-17
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-17&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-17
Well ID: T0607302618-MW-17 Well Type: MONITORING
C14
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000104776
gned_name=MW-16
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-16&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-16
Well ID: T0607302618-MW-16 Well Type: MONITORING
C13
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000070482
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-19
gned_name=MW-9
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-9&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-9
Well ID: T0607302618-MW-9 Well Type: MONITORING
C20
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000003858
GeoTracker Data: Not Reported
amp_date=&global_id=&assigned_name=USGS-325048116580401&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=USGSNEW&s Other Name: USGS-325048116580401 GAMA PFAS Testing: Not Reported Source: United States Geological Survey
Well ID: USGS-325048116580401 Well Type: UNK
D19
ESE
1/4 - 1/2 Mile
Higher
CA WELLS CAUSGSN00003066
gned_name=MW-10
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-10&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-10
Well ID: T0607302618-MW-10 Well Type: MONITORING
C18
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000102879
gned_name=MW-13
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-13&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-13
Well ID: T0607302618-MW-13 Well Type: MONITORING
C17
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000100286
Well Hole Depth Units: Not Reported
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-20
gned_name=MW-17
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-17&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-17
Well ID: T0607302280-MW-17 Well Type: MONITORING
E24
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000106149
gned_name=MW-15
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-15&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-15
Well ID: T0607302618-MW-15 Well Type: MONITORING
C23
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000046896
gned_name=MW-3
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-3&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-3
Well ID: T0607302618-MW-3 Well Type: MONITORING
C22
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000087991
gned_name=MW-8
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-8&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-8
Well ID: T0607302618-MW-8 Well Type: MONITORING
C21
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000014109
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-21
gned_name=MW-5
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-5&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-5
Well ID: T0607302618-MW-5 Well Type: MONITORING
C28
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000075043
gned_name=MW-14
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-14&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-14
Well ID: T0607302618-MW-14 Well Type: MONITORING
C27
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000103694
gned_name=MW-1
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-1&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-1
Well ID: T0607302618-MW-1 Well Type: MONITORING
C26
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000051770
gned_name=MW-2
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-2&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-2
Well ID: T0607302618-MW-2 Well Type: MONITORING
C25
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000080398
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-22
gned_name=MW-7
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-7&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-7
Well ID: T0607302618-MW-7 Well Type: MONITORING
C32
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000138987
gned_name=MW-4
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-4&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-4
Well ID: T0607302618-MW-4 Well Type: MONITORING
C31
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000017086
gned_name=MW-6
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-6&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-6
Well ID: T0607302618-MW-6 Well Type: MONITORING
C30
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000022075
gned_name=MW-16
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-16&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-16
Well ID: T0607302280-MW-16 Well Type: MONITORING
E29
NE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000093811
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-23
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W22G002S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W22G002S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W22G002S Well Type: UNK
F36
NE
1/4 - 1/2 Mile
Higher
CA WELLS CADWR0000008714
gned_name=MW-10
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-10&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-10
Well ID: T0607302280-MW-10 Well Type: MONITORING
E35
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000006551
gned_name=MW-12
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-12&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-12
Well ID: T0607302618-MW-12 Well Type: MONITORING
C34
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000078820
gned_name=MW-11
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302618&assi date=&global_id=T0607302618&assigned_name=MW-11&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-11
Well ID: T0607302618-MW-11 Well Type: MONITORING
C33
North
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000049766
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-24
gned_name=MW-7
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-7&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-7
Well ID: T0607302280-MW-7 Well Type: MONITORING
E40
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000134270
gned_name=MW-9
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-9&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-9
Well ID: T0607302280-MW-9 Well Type: MONITORING
E39
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000033499
gned_name=MW-11
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-11&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-11
Well ID: T0607302280-MW-11 Well Type: MONITORING
E38
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000131320
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W22G001S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W22G001S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W22G001S Well Type: UNK
F37
NE
1/4 - 1/2 Mile
Higher
CA WELLS CADWR0000001600
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-25
gned_name=MW-8
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-8&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-8
Well ID: T0607302280-MW-8 Well Type: MONITORING
E44
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000065356
gned_name=MW-14
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-14&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-14
Well ID: T0607302280-MW-14 Well Type: MONITORING
E43
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000120681
gned_name=EW-2
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=EW-2&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: EW-2
Well ID: T0607302280-EW-2 Well Type: MONITORING
E42
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000117944
gned_name=MW-5
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-5&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-5
Well ID: T0607302280-MW-5 Well Type: MONITORING
E41
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000101025
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-26
gned_name=MW-4
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-4&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-4
Well ID: T0607302280-MW-4 Well Type: MONITORING
E48
NNE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000046659
gned_name=MW-12
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-12&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-12
Well ID: T0607302280-MW-12 Well Type: MONITORING
E47
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000116998
gned_name=EW-1
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=EW-1&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: EW-1
Well ID: T0607302280-EW-1 Well Type: MONITORING
E46
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000100042
gned_name=MW-18
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-18&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-18
Well ID: T0607302280-MW-18 Well Type: MONITORING
E45
NNE
1/4 - 1/2 Mile
Higher
CA WELLS CAEDF0000120551
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-27
gned_name=MW-2
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-2&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-2
Well ID: T0607302280-MW-2 Well Type: MONITORING
E52
NNE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000099776
gned_name=MW-3
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-3&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-3
Well ID: T0607302280-MW-3 Well Type: MONITORING
E51
NNE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000052018
gned_name=MW-15
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-15&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-15
Well ID: T0607302280-MW-15 Well Type: MONITORING
E50
NNE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000083615
gned_name=MW-1
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-1&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-1
Well ID: T0607302280-MW-1 Well Type: MONITORING
E49
NNE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000052163
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-28
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W22D001S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W22D001S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W22D001S Well Type: UNK
56 NNW
1/2 - 1 Mile
Higher
CA WELLS CADWR0000004193
gned_name=MW-8
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607301535&assi date=&global_id=T0607301535&assigned_name=MW-8&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-8
Well ID: T0607301535-MW-8 Well Type: MONITORING
G55
NW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000049461
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W27B002S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W27B002S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W27B002S Well Type: UNK
54 SE
1/2 - 1 Mile
Higher
CA WELLS CADWR0000007857
gned_name=MW-6
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302280&assi date=&global_id=T0607302280&assigned_name=MW-6&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-6
Well ID: T0607302280-MW-6 Well Type: MONITORING
E53
NNE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000021375
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-29
gned_name=MW-7
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607301535&assi date=&global_id=T0607301535&assigned_name=MW-7&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-7
Well ID: T0607301535-MW-7 Well Type: MONITORING
G60
NW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000013617
gned_name=MW-10
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607301535&assi date=&global_id=T0607301535&assigned_name=MW-10&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-10
Well ID: T0607301535-MW-10 Well Type: MONITORING
G59
NW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000048178
gned_name=MW-6
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607301535&assi date=&global_id=T0607301535&assigned_name=MW-6&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-6
Well ID: T0607301535-MW-6 Well Type: MONITORING
G58
NW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000057002
gned_name=MW-9
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607301535&assi date=&global_id=T0607301535&assigned_name=MW-9&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-9
Well ID: T0607301535-MW-9 Well Type: MONITORING
G57
NW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000136930
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-30
gned_name=MW-2
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607301535&assi date=&global_id=T0607301535&assigned_name=MW-2&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-2
Well ID: T0607301535-MW-2 Well Type: MONITORING
G64
NW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000123696
gned_name=MW-4
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607301535&assi date=&global_id=T0607301535&assigned_name=MW-4&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-4
Well ID: T0607301535-MW-4 Well Type: MONITORING
G63
NW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000075875
gned_name=MW-5
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607301535&assi date=&global_id=T0607301535&assigned_name=MW-5&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-5
Well ID: T0607301535-MW-5 Well Type: MONITORING
G62
NW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000111516
gned_name=VE-1
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607301535&assi date=&global_id=T0607301535&assigned_name=VE-1&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: VE-1
Well ID: T0607301535-VE-1 Well Type: MONITORING
G61
NW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000079829
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-31
Enforcement Detail: St Boil Water Order Enforcement Category: Not Reported Enforcemnt FY: 2004 Enforcement Action: 10/27/2003
Violation ID: Not Reported Orig Code: S
Latitude: 325017 Longitude: 1165823
Population served: over 100,000 Persons Treatment: Mixed (treated and untreated) County FIPS: 073 City served: SANTEE-ALPINE V
County FIPS: Not Reported City served: SANTEE-ALPINE V
System state: CA System zip: 920729003
System address: PO BOX 70 System city: SANTEE
System name: PADRE DAM MWD System address: Not Reported Date system deactivated: Not Reported Retail population: 00117000 Activity status: Active Date system activated: 7706
PWS zip: Not Reported PWS ID: CA3710037
PWS city: Not Reported PWS state: Not Reported
PWS name: Not Reported PWS address: Not Reported
PWS ID: CA3710037 PWS type: Not Reported
Source code: Purchases surface water Population: 75000
Zip: 920729003 Owner: PADRE DAM MWD
City: SANTEE State: CA
Address: Not Reported Care of: Not Reported
PWS ID: CA3710037 PWS name: PADRE DAM MWD
Pwsactivitycode: A
Contactstate: CA Contactzip: 92071
Contactaddress2: Not Reported Contactcity: SANTEE
Contactphone: 619-258-4663 Contactaddress1: PO BOX 719003 Contact: KOWALSKI, FRANK Contactorgname: KOWALSKI, FRANK Pwstype: CWS Owner: Local_Govt
Pwssvcconn: 23379 Psource longname: Purch_surface_water Status: Active Retpopsrvd: 96589
Zipserved: Not Reported Fipscounty: 06073
Cityserved: Not Reported Stateserved: CA
Pwsid: CA3710037 Pwsname: PADRE DAM MWD
Epa region: 09 State: CA
66 South
1/2 - 1 Mile
Higher
FRDS PWS CA3710037
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W27A005S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W27A005S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W27A005S Well Type: UNK
65 SE
1/2 - 1 Mile
Higher
CA WELLS CADWR0000002796
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-32
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W27G005S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W27G005S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W27G005S Well Type: UNK
I70
SSE
1/2 - 1 Mile
Higher
CA WELLS CADWR0000019673
Date: 07/05/1995
Average Water Depth: Not Reported
Deep Water Depth: 13
Shallow Water Depth: 10.5
Groundwater Flow: Varies
69 Site ID: Not Reported
SSW
1/2 - 1 Mile
Lower
AQUIFLOW 33855
Well Hole Depth Units: Not Reported
Well Depth Units: Not Reported Well Hole Depth: Not Reported Construction Date: Not Reported Well Depth: Not Reported Formation Type: Not Reported Aquifer Type: Not Reported Aquifer: California Coastal Basin aquifers
Contrib Drainage Area: Not Reported Contrib Drainage Area Unts: Not Reported Drainage Area: Not Reported Drainage Area Units: Not Reported Description: Not Reported HUC: 18070304
Monitor Location: 015S001W22G002S Type: Well
Organization Name: USGS California Water Science Center Organization ID: USGS-CA
H68
NE
1/2 - 1 Mile
Higher
FED USGS USGS40000129937
GeoTracker Data: Not Reported
amp_date=&global_id=&assigned_name=USGS-325123116580001&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=USGSNEW&s Other Name: USGS-325123116580001 GAMA PFAS Testing: Not Reported Source: United States Geological Survey
Well ID: USGS-325123116580001 Well Type: UNK
H67
NE
1/2 - 1 Mile
Higher
CA WELLS CAUSGSN00015577
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-33
gned_name=W-25
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-25&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-25
Well ID: T0607303021-W-25 Well Type: MONITORING
J74
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000060825
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W27G001S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W27G001S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W27G001S Well Type: UNK
I73
SSE
1/2 - 1 Mile
Higher
CA WELLS CADWR0000023171
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W27G006S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W27G006S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W27G006S Well Type: UNK
I72
SSE
1/2 - 1 Mile
Higher
CA WELLS CADWR0000026129
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W27G007S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W27G007S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W27G007S Well Type: UNK
I71
SSE
1/2 - 1 Mile
Higher
CA WELLS CADWR0000014893
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-34
gned_name=W-18
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-18&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-18
Well ID: T0607303021-W-18 Well Type: MONITORING
J78
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000109451
gned_name=27
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=27&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: 27
Well ID: T0607303021-27 Well Type: MONITORING
J77
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000115243
gned_name=W-22
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-22&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-22
Well ID: T0607303021-W-22 Well Type: MONITORING
J76
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000092105
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W23N001S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W23N001S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W23N001S Well Type: UNK
75 ESE
1/2 - 1 Mile
Higher
CA WELLS CADWR0000007719
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-35
gned_name=MW-2
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-2&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-2
Well ID: T0607302332-MW-2 Well Type: MONITORING
K82
SSW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000102248
gned_name=W-19
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-19&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-19
Well ID: T0607303021-W-19 Well Type: MONITORING
J81
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000106266
gned_name=MW-4
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-4&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-4
Well ID: T0607302332-MW-4 Well Type: MONITORING
K80
SSW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000093837
gned_name=MW-9
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-9&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-9
Well ID: T0607302332-MW-9 Well Type: MONITORING
K79
SSW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000099670
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-36
Source: EDF Other Name: W-17
Well ID: T0607303021-W-17 Well Type: MONITORING
J87
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000069424
Date: 07/25/1988
Average Water Depth: 13
Deep Water Depth: Not Reported
Shallow Water Depth: Not Reported
Groundwater Flow: Not Reported
K86 Site ID: Not Reported
SW
1/2 - 1 Mile
Lower
AQUIFLOW 38759
gned_name=W-20
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-20&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-20
Well ID: T0607303021-W-20 Well Type: MONITORING
J85
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000114839
gned_name=W-24
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-24&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-24
Well ID: T0607303021-W-24 Well Type: MONITORING
J84
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000100627
gned_name=MW-3
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-3&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-3
Well ID: T0607302332-MW-3 Well Type: MONITORING
K83
SSW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000060472
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-37
date=&global_id=T0607303021&assigned_name=W-16&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-16
Well ID: T0607303021-W-16 Well Type: MONITORING
J91
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000034301
gned_name=MW-5
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-5&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-5
Well ID: T0607302332-MW-5 Well Type: MONITORING
K90
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000009833
gned_name=W-23
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-23&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-23
Well ID: T0607303021-W-23 Well Type: MONITORING
J89
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000131478
gned_name=MW-10
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-10&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-10
Well ID: T0607302332-MW-10 Well Type: MONITORING
K88
SSW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000140458
gned_name=W-17
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-17&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-38
gned_name=MW-8
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-8&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-8
Well ID: T0607302332-MW-8 Well Type: MONITORING
K95
SSW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000114995
gned_name=W-15
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-15&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-15
Well ID: T0607303021-W-15 Well Type: MONITORING
J94
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000030745
gned_name=W-21
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-21&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-21
Well ID: T0607303021-W-21 Well Type: MONITORING
J93
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000115246
gned_name=MW-1
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-1&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-1
Well ID: T0607302332-MW-1 Well Type: MONITORING
K92
SSW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000041070
gned_name=W-16
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-39
gned_name=MW-7
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-7&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-7
Well ID: T0607302332-MW-7 Well Type: MONITORING
K99
SSW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000074175
gned_name=MW-11
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-11&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-11
Well ID: T0607302332-MW-11 Well Type: MONITORING
K98
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000012435
gned_name=W-13
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-13&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-13
Well ID: T0607303021-W-13 Well Type: MONITORING
J97
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000042666
gned_name=28
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=28&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: 28
Well ID: T0607303021-28 Well Type: MONITORING
J96
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000084373
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-40
gned_name=31
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=31&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: 31
Well ID: T0607303021-31 Well Type: MONITORING
J103
SE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000097166
gned_name=MW-4
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=MW-4&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-4
Well ID: T0607303021-MW-4 Well Type: MONITORING
J102
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000081592
gned_name=W-14
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-14&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-14
Well ID: T0607303021-W-14 Well Type: MONITORING
J101
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000064558
gned_name=32
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=32&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: 32
Well ID: T0607303021-32 Well Type: MONITORING
J100
SE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000058938
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-41
gned_name=MW-2
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=MW-2&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-2
Well ID: T0607303021-MW-2 Well Type: MONITORING
J107
SE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000074976
gned_name=W-12
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=W-12&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: W-12
Well ID: T0607303021-W-12 Well Type: MONITORING
J106
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000087777
gned_name=MW-6
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607302332&assi date=&global_id=T0607302332&assigned_name=MW-6&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-6
Well ID: T0607302332-MW-6 Well Type: MONITORING
K105
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000059940
gned_name=26
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=26&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: 26
Well ID: T0607303021-26 Well Type: MONITORING
J104
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000107258
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-42
gned_name=MW-1
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=MW-1&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-1
Well ID: T0607303021-MW-1 Well Type: MONITORING
J111
SE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000104365
gned_name=MW-3
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=MW-3&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-3
Well ID: T0607303021-MW-3 Well Type: MONITORING
J110
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000067998
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W27H001S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W27H001S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W27H001S Well Type: UNK
109
SE
1/2 - 1 Mile
Higher
CA WELLS CADWR0000004413
gned_name=MW-6
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=MW-6&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-6
Well ID: T0607303021-MW-6 Well Type: MONITORING
J108
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000099868
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-43
gned_name=MW-6
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-6&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-6
Well ID: SL209164191-MW-6 Well Type: MONITORING
L115
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000014240
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W27L001S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W27L001S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W27L001S Well Type: UNK
114
South
1/2 - 1 Mile
Higher
CA WELLS CADWR0000009465
igned_name=MW-1
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T06019785894&ass date=&global_id=T06019785894&assigned_name=MW-1&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-1
Well ID: T06019785894-MW-1 Well Type: MONITORING
113
SSW
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000050860
gned_name=MW-5
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=T0607303021&assi date=&global_id=T0607303021&assigned_name=MW-5&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-5
Well ID: T0607303021-MW-5 Well Type: MONITORING
J112
SSE
1/2 - 1 Mile
Higher
CA WELLS CAEDF0000038778
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-44
gned_name=MW-2
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-2&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-2
Well ID: SL209164191-MW-2 Well Type: MONITORING
L119
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000142465
gned_name=MW-4
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-4&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-4
Well ID: SL209164191-MW-4 Well Type: MONITORING
L118
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000126882
gned_name=MW-5
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-5&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-5
Well ID: SL209164191-MW-5 Well Type: MONITORING
M117
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000106139
gned_name=MW-3
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-3&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-3
Well ID: SL209164191-MW-3 Well Type: MONITORING
L116
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000076119
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-45
gned_name=MW-9
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-9&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-9
Well ID: SL209164191-MW-9 Well Type: MONITORING
L123
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000137654
gned_name=MW-12
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-12&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-12
Well ID: SL209164191-MW-12 Well Type: MONITORING
M122
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000118361
gned_name=MW-7
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-7&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-7
Well ID: SL209164191-MW-7 Well Type: MONITORING
L121
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000010536
gned_name=MW-1
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-1&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-1
Well ID: SL209164191-MW-1 Well Type: MONITORING
L120
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000035180
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-46
gned_name=MW-13
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-13&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-13
Well ID: SL209164191-MW-13 Well Type: MONITORING
N127
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000035344
gned_name=MW-14
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-14&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-14
Well ID: SL209164191-MW-14 Well Type: MONITORING
N126
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000037794
gned_name=MW-10
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-10&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-10
Well ID: SL209164191-MW-10 Well Type: MONITORING
M125
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000095232
Date: 09/09/1988
Average Water Depth: 10
Deep Water Depth: Not Reported
Shallow Water Depth: Not Reported
Groundwater Flow: NNW
M124 Site ID: Not Reported
SW
1/2 - 1 Mile
Lower
AQUIFLOW 38454
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-47
gned_name=MW-15
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-15&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-15
Well ID: SL209164191-MW-15 Well Type: MONITORING
N131
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000137743
Well Hole Depth Units: Not Reported
Well Depth Units: Not Reported Well Hole Depth: Not Reported Construction Date: Not Reported Well Depth: Not Reported Formation Type: Not Reported Aquifer Type: Not Reported Aquifer: California Coastal Basin aquifers
Contrib Drainage Area: Not Reported Contrib Drainage Area Unts: Not Reported Drainage Area: Not Reported Drainage Area Units: Not Reported Description: Not Reported HUC: 18070304
Monitor Location: 015S001W28R005S Type: Well
Organization Name: USGS California Water Science Center Organization ID: USGS-CA
O130
SSW
1/2 - 1 Mile
Higher
FED USGS USGS40000129898
gned_name=MW-11
GeoTracker Data: https://geotracker.waterboards.ca.gov/profile_report.asp?cmd=MWEDFResults&global_id=SL209164191&assi date=&global_id=SL209164191&assigned_name=MW-11&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=EDF&samp_ GAMA PFAS Testing: Not Reported
Source: EDF Other Name: MW-11
Well ID: SL209164191-MW-11 Well Type: MONITORING
M129
SW
1/2 - 1 Mile
Lower
CA WELLS CAEDF0000048880
GeoTracker Data: Not Reported
date=&global_id=&assigned_name=15S01W28G001S&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=DWR&samp_ Other Name: 15S01W28G001S GAMA PFAS Testing: Not Reported Source: Department of Water Resources
Well ID: 15S01W28G001S Well Type: UNK
M128
SW
1/2 - 1 Mile
Lower
CA WELLS CADWR0000025975
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-48
Date: 07/05/1995
Average Water Depth: Not Reported
Deep Water Depth: 13
Shallow Water Depth: 10.5
Groundwater Flow: Varies
3G Site ID: Not Reported
SSW
1/2 - 1 Mile
Lower
AQUIFLOW 33855
Date: 07/25/1988
Average Water Depth: 13
Deep Water Depth: Not Reported
Shallow Water Depth: Not Reported
Groundwater Flow: Not Reported
2G Site ID: Not Reported
SW
1/2 - 1 Mile
Lower
AQUIFLOW 38759
Date: 09/09/1988
Average Water Depth: 10
Deep Water Depth: Not Reported
Shallow Water Depth: Not Reported
Groundwater Flow: NNW
1G Site ID: Not Reported
SW
1/2 - 1 Mile
Lower
AQUIFLOW 38454
GeoTracker Data: Not Reported
amp_date=&global_id=&assigned_name=USGS-325004116584401&store_num= Groundwater Quality Data: https://gamagroundwater.waterboards.ca.gov/gama/gamamap/public/GamaDataDisplay.asp?dataset=USGSNEW&s Other Name: USGS-325004116584401 GAMA PFAS Testing: Not Reported Source: United States Geological Survey
Well ID: USGS-325004116584401 Well Type: UNK
O132
SSW
1/2 - 1 Mile
Higher
CA WELLS CAUSGSN00015711
Map ID
Direction
Distance
Elevation Database EDR ID Number
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS ®
TC7493604.2s Page A-49
Basement Not Reported Not Reported Not Reported Not Reported Living Area - 2nd Floor Not Reported Not Reported Not Reported Not Reported Living Area - 1st Floor -0.100 pCi/L 100% 0% 0%
Area Average Activity % <4 pCi/L % 4-20 pCi/L % >20 pCi/L Number of sites tested: 1
Federal Area Radon Information for Zip Code: 92071
: Zone 3 indoor average level < 2 pCi/L.
: Zone 2 indoor average level >= 2 pCi/L and <= 4 pCi/L.
Note: Zone 1 indoor average level > 4 pCi/L.
Federal EPA Radon Zone for SAN DIEGO County: 3
92071 27 2
______ ________ ________
Zipcode Num Tests > 4 pCi/L
Radon Test Results
State Database: CA Radon
AREA RADON INFORMATION
GEOCHECK - PHYSICAL SETTING SOURCE MAP FINDINGS
RADON
®
TOPOGRAPHIC INFORMATION
USGS 7.5’ Digital Elevation Model (DEM)
Source: United States Geologic Survey
EDR acquired the USGS 7.5’ Digital Elevation Model in 2002 and updated it in 2006. The 7.5 minute DEM corresponds to the USGS 1:24,000- and 1:25,000-scale topographic quadrangle maps. The DEM provides elevation data with consistent elevation units and projection.
Current USGS 7.5 Minute Topographic Map
Source: U.S. Geological Survey
HYDROLOGIC INFORMATION
Flood Zone Data: This data was obtained from the Federal Emergency Management Agency (FEMA). It depicts 100-year and 500-year flood zones as defined by FEMA. It includes the National Flood Hazard Layer (NFHL) which incorporates Flood Insurance Rate Map (FIRM) data and Q3 data from FEMA in areas not covered by NFHL.
Source: FEMA
Telephone: 877-336-2627
Date of Government Version: 2003, 2015
NWI: National Wetlands Inventory. This data, available in select counties across the country, was obtained by EDR in 2002, 2005, 2010 and 2015 from the U.S. Fish and Wildlife Service.
State Wetlands Data: Wetland Inventory
Source: Department of Fish and Wildlife
Telephone: 916-445-0411
HYDROGEOLOGIC INFORMATION
AQUIFLOW Information System R
Source: EDR proprietary database of groundwater flow information EDR has developed the AQUIFLOW Information System (AIS) to provide data on the general direction of groundwater flow at specific points. EDR has reviewed reports submitted to regulatory authorities at select sites and has extracted the date of the report, hydrogeologically determined groundwater flow direction and depth to water table information.
GEOLOGIC INFORMATION
Geologic Age and Rock Stratigraphic Unit
Source: P.G. Schruben, R.E. Arndt and W.J. Bawiec, Geology of the Conterminous U.S. at 1:2,500,000 Scale - A digital representation of the 1974 P.B. King and H.M. Beikman Map, USGS Digital Data Series DDS - 11 (1994).
STATSGO: State Soil Geographic Database
Source: Department of Agriculture, Natural Resources Conservation Service (NRCS) The U.S. Department of Agriculture’s (USDA) Natural Resources Conservation Service (NRCS) leads the national Conservation Soil Survey (NCSS) and is responsible for collecting, storing, maintaining and distributing soil survey information for privately owned lands in the United States. A soil map in a soil survey is a representation of soil patterns in a landscape. Soil maps for STATSGO are compiled by generalizing more detailed (SSURGO) soil survey maps.
SSURGO: Soil Survey Geographic Database
Source: Department of Agriculture, Natural Resources Conservation Service (NRCS) Telephone: 800-672-5559
SSURGO is the most detailed level of mapping done by the Natural Resources Conservation Service, mapping scales generally range from 1:12,000 to 1:63,360. Field mapping methods using national standards are used to construct the soil maps in the Soil Survey Geographic (SSURGO) database. SSURGO digitizing duplicates the original soil survey maps. This level of mapping is designed for use by landowners, townships and county natural resource planning and management.
TC7493604.2s Page PSGR-1
PHYSICAL SETTING SOURCE RECORDS SEARCHED
LOCAL / REGIONAL WATER AGENCY RECORDS
FEDERAL WATER WELLS
PWS: Public Water Systems
Source: EPA/Office of Drinking Water
Telephone: 202-564-3750
Public Water System data from the Federal Reporting Data System. A PWS is any water system which provides water to at least 25 people for at least 60 days annually. PWSs provide water from wells, rivers and other sources.
PWS ENF: Public Water Systems Violation and Enforcement Data Source: EPA/Office of Drinking Water
Telephone: 202-564-3750
Violation and Enforcement data for Public Water Systems from the Safe Drinking Water Information System (SDWIS) after August 1995. Prior to August 1995, the data came from the Federal Reporting Data System (FRDS).
USGS Water Wells: USGS National Water Inventory System (NWIS) This database contains descriptive information on sites where the USGS collects or has collected data on surface water and/or groundwater. The groundwater data includes information on wells, springs, and other sources of groundwater.
OTHER STATE DATABASE INFORMATION
Groundwater Ambient Monitoring & Assessment Program
State Water Resources Control Board
Telephone: 916-341-5577
The GAMA Program is Californias comprehensive groundwater quality monitoring program. GAMA collects data by testing the untreated, raw water in different types of wells for naturally-occurring and man-made chemicals. The GAMA data includes Domestic, Monitoring and Municipal well types from the following sources, Department of Water Resources, Department of Heath Services, EDF, Agricultural Lands, Lawrence Livermore National Laboratory, Department of Pesticide Regulation, United States Geological Survey, Groundwater Ambient Monitoring and Assessment Program and Local Groundwater Projects.
Water Well Database
Source: Department of Water Resources
Telephone: 916-651-9648
California Drinking Water Quality Database
Source: Department of Public Health
Telephone: 916-324-2319
The database includes all drinking water compliance and special studies monitoring for the state of California since 1984. It consists of over 3,200,000 individual analyses along with well and water system information.
California Oil and Gas Well Locations
Source: Dept of Conservation, Geologic Energy Management Division Telephone: 916-323-1779
Oil and Gas well locations in the state.
California Earthquake Fault Lines
Source: California Division of Mines and Geology
The fault lines displayed on EDR’s Topographic map are digitized quaternary fault lines prepared in 1975 by the United State Geological Survey. Additional information (also from 1975) regarding activity at specific fault lines comes from California’s Preliminary Fault Activity Map prepared by the California Division of Mines and Geology.
RADON
State Database: CA Radon
Source: Department of Public Health
Telephone: 916-210-8558
Radon Database for California
TC7493604.2s Page PSGR-2
PHYSICAL SETTING SOURCE RECORDS SEARCHED
Area Radon Information
Source: USGS
Telephone: 703-356-4020
The National Radon Database has been developed by the U.S. Environmental Protection Agency (USEPA) and is a compilation of the EPA/State Residential Radon Survey and the National Residential Radon Survey.
The study covers the years 1986 - 1992. Where necessary data has been supplemented by information collected at private sources such as universities and research institutions.
EPA Radon Zones
Source: EPA
Telephone: 703-356-4020
Sections 307 & 309 of IRAA directed EPA to list and identify areas of U.S. with the potential for elevated indoor radon levels.
OTHER
Airport Landing Facilities: Private and public use landing facilities Source: Federal Aviation Administration, 800-457-6656
Epicenters: World earthquake epicenters, Richter 5 or greater Source: Department of Commerce, National Oceanic and Atmospheric Administration California Earthquake Fault Lines: The fault lines displayed on EDR’s Topographic map are digitized quaternary fault lines, prepared in 1975 by the United State Geological Survey. Additional information (also from 1975) regarding activity at specific fault lines comes from California’s Preliminary Fault Activity Map prepared by the California Division of Mines and Geology.
STREET AND ADDRESS INFORMATION
© 2015 TomTom North America, Inc. All rights reserved. This material is proprietary and the subject of copyright protection and other intellectual property rights owned by or licensed to Tele Atlas North America, Inc. The use of this material is subject to the terms of a license agreement. You will be held liable for any unauthorized copying or disclosure of this material.
TC7493604.2s Page PSGR-3
PHYSICAL SETTING SOURCE RECORDS SEARCHED
APPENDIX E
HISTORICAL RECORDS
Certified Sanborn® Map Report
Inquiry Number:
6 Armstrong Road, 4th floor
Shelton, CT 06484
Toll Free: 800.352.0050
www.edrnet.com
Not Reported Not Reported SANTEE, CA 92071 November 09, 20237493604.3 Certified Sanborn® Map Report
Certified Sanborn Results:
Disclaimer - Copyright and Trademark Notice
EDR and its logos (including Sanborn and Sanborn Map) are trademarks of Environmental Data Resources, LLC or its affiliates. All other trademarks used herein are the property of their respective owners.
- page
The Sanborn Library includes more than 1.2 million
fire insurance maps from Sanborn, Bromley, Perris &
Browne, Hopkins, Barlow and others which track
historical property usage in approximately 12,000
American cities and towns. Collections searched:
Library of Congress
University Publications of America
EDR Private Collection
The Sanborn Library LLC Since 1866™
Limited Permission To Make Copies
Sanborn® Library search results
EDR Inquiry # Contact:
Site Name: Client Name:
Certification #
PO #
Project
11/09/23 Not Reported Not Reported Stantec 735 E. Carnegie Drive, Suite 280 SANTEE, CA 92071 7493604.3 SAN BERNARDINO, CA 92408 Alicia R Jansen The Sanborn Library has been searched by EDR and maps covering the target property location as provided by Stantec were identified for the years listed below. The Sanborn Library is the largest, most complete collection of fire insurance maps. The collection includes maps from Sanborn, Bromley, Perris & Browne, Hopkins, Barlow, and others. Only Environmental Data Resources Inc. (EDR) is authorized to grant rights for commercial reproduction of maps by the Sanborn Library LLC, the copyright holder for the collection. Results can be authenticated by visiting www.edrnet.com/sanborn.
The Sanborn Library is continually enhanced with newly identified map archives. This report accesses all maps in the collection as of the day this report was generated. 4D6B-4777-BFC9 NA UNMAPPED PROPERTY CV Santee 3 This report certifies that the complete holdings of the Sanborn Library, LLC collection have been searched based on client supplied target property information, and fire insurance maps covering the target property were not found.
Certification #: 4D6B-4777-BFC9
Stantec (the client) is permitted to make up to FIVE photocopies of this Sanborn Map transmittal and each fire insurance map accompanying this report solely for the limited use of its customer. No one other than the client is authorized to make copies. Upon request made directly to an EDR Account Executive, the client may be permitted to make a limited number of additional photocopies. This permission is conditioned upon compliance by the client, its customer and their agents with EDR's copyright policy; a copy of which is available upon request.
This Report contains certain information obtained from a variety of public and other sources reasonably available to Environmental Data Resources, LLC. It cannot be concluded from this Report that coverage information for the target and surrounding properties does not exist from other sources. This Report is provided on an “AS IS”, “AS AVAILABLE” basis. NO WARRANTY EXPRESS OR IMPLIED IS MADE WHATSOEVER IN CONNECTION WITH THIS REPORT.
ENVIRONMENTAL DATA RESOURCES, LLC AND ITS SUBSIDIARIES, AFFILIATES AND THIRD PARTY SUPPLIERS DISCLAIM ALL WARRANTIES, OF ANY
KIND OR NATURE, EXPRESS OR IMPLIED, ARISING OUT OF OR RELATED TO THIS REPORT OR ANY OF THE DATA AND INFORMATION PROVIDED IN
THIS REPORT, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES REGARDING ACCURACY, QUALITY, CORRECTNESS, COMPLETENESS,
COMPREHENSIVENESS, SUITABILITY, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, NON-INFRINGEMENT, MISAPPROPRIATION, OR OTHERWISE. ALL RISK IS ASSUMED BY THE USER. IN NO EVENT SHALL ENVIRONMENTAL DATA RESOURCES, LLC OR ITS
SUBSIDIARIES, AFFILIATES OR THIRD PARTY SUPPLIERS BE LIABLE TO ANYONE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL,
CONSEQUENTIAL OR OTHER DAMAGES OF ANY TYPE OR KIND (INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS, LOSS OF USE, OR LOSS OF DATA), ARISING OUT OF OR IN ANY WAY CONNECTED WITH THIS REPORT OR ANY OF THE DATA AND INFORMATION PROVIDED IN THIS REPORT.
Any analyses, estimates, ratings, environmental risk levels, or risk codes provided in this Report are provided for illustrative purposes only, and are not intended to provide, nor should they be interpreted as providing any facts regarding, or prediction or forecast of, any environmental risk for any property. Only an assessment performed by a qualified environmental professional can provide findings, opinions or conclusions regarding the environmental risk or conditions in, on or at any property.
Copyright 2023 by Environmental Data Resources, Inc. All rights reserved. Reproduction in any media or format, in whole or in part, of any report or map of Environmental Data Resources, Inc., or its affiliates, is prohibited without prior written permission. 7493604 3 2 EDR Historical Topo Map Report
Inquiry Number:
6 Armstrong Road, 4th floor
Shelton, CT 06484
Toll Free: 800.352.0050
www.edrnet.com
with QuadMatch™
Not Reported Not Reported SANTEE, CA 92071 November 09, 20237493604.4 EDR Historical Topo Map Report
EDR Inquiry #
Search Results:
P.O.#
Project:
Maps Provided:
Disclaimer - Copyright and Trademark Notice
EDR and its logos (including Sanborn and Sanborn Map) are trademarks of Environmental Data Resources, LLC or its affiliates. All other trademarks used herein are the property of their respective owners.
- page
Coordinates:
Latitude:
Longitude:
UTM Zone:
UTM X Meters:
UTM Y Meters:
Elevation:
Contact:
Site Name: Client Name:
2018
2015
2012
1996
1975
1967
1955
1948
1947
1942
1939
1903
1901
1893
11/09/23 Not Reported Stantec Not Reported 735 E. Carnegie Drive, Suite 280 SANTEE, CA 92071 SAN BERNARDINO, CA 92408 7493604.4 Alicia R Jansen EDR Topographic Map Library has been searched by EDR and maps covering the target property location as provided by Stantec were identified for the years listed below. EDR’s Historical Topo Map Report is designed to assist professionals in evaluating potential liability on a target property resulting from past activities. EDRs Historical Topo Map Report includes a search of a collection of public and private color historical topographic maps, dating back to the late 1800s.
NA 32.848446 32° 50' 54" North CV Santee 3 -116.975637 -116° 58' 32" West Zone 11 North 502279.77 3634486.12 343.00' above sea level This Report contains certain information obtained from a variety of public and other sources reasonably available to Environmental Data Resources, LLC. It cannot be concluded from this Report that coverage information for the target and surrounding properties does not exist from other sources. This Report is provided on an “AS IS”, “AS AVAILABLE” basis. NO WARRANTY EXPRESS OR IMPLIED IS MADE WHATSOEVER IN CONNECTION WITH THIS REPORT.
ENVIRONMENTAL DATA RESOURCES, LLC AND ITS SUBSIDIARIES, AFFILIATES AND THIRD PARTY SUPPLIERS DISCLAIM ALL WARRANTIES, OF ANY
KIND OR NATURE, EXPRESS OR IMPLIED, ARISING OUT OF OR RELATED TO THIS REPORT OR ANY OF THE DATA AND INFORMATION PROVIDED IN
THIS REPORT, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES REGARDING ACCURACY, QUALITY, CORRECTNESS, COMPLETENESS,
COMPREHENSIVENESS, SUITABILITY, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, NON-INFRINGEMENT, MISAPPROPRIATION, OR OTHERWISE. ALL RISK IS ASSUMED BY THE USER. IN NO EVENT SHALL ENVIRONMENTAL DATA RESOURCES, LLC OR ITS
SUBSIDIARIES, AFFILIATES OR THIRD PARTY SUPPLIERS BE LIABLE TO ANYONE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL,
CONSEQUENTIAL OR OTHER DAMAGES OF ANY TYPE OR KIND (INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS, LOSS OF USE, OR LOSS OF DATA), ARISING OUT OF OR IN ANY WAY CONNECTED WITH THIS REPORT OR ANY OF THE DATA AND INFORMATION PROVIDED IN THIS REPORT.
Any analyses, estimates, ratings, environmental risk levels, or risk codes provided in this Report are provided for illustrative purposes only, and are not intended to provide, nor should they be interpreted as providing any facts regarding, or prediction or forecast of, any environmental risk for any property. Only an assessment performed by a qualified environmental professional can provide findings, opinions or conclusions regarding the environmental risk or conditions in, on or at any property.
Copyright 2023 by Environmental Data Resources, Inc. All rights reserved. Reproduction in any media or format, in whole or in part, of any report or map of Environmental Data Resources, Inc., or its affiliates, is prohibited without prior written permission. 7493604 4 2 page
Topo Sheet Key
This EDR Topo Map Report is based upon the following USGS topographic map sheets. -
2018 Source Sheets
2018
El Cajon
7.5-minute, 24000
2018
La Mesa
7.5-minute, 24000
2015 Source Sheets
2015
El Cajon
7.5-minute, 24000
2015
La Mesa
7.5-minute, 24000
2012 Source Sheets
2012
El Cajon
7.5-minute, 24000
2012
La Mesa
7.5-minute, 24000
1996 Source Sheets
1996
El Cajon
7.5-minute, 24000
7493604 4 3
page
Topo Sheet Key
This EDR Topo Map Report is based upon the following USGS topographic map sheets. -
1975 Source Sheets
1975
La Mesa
7.5-minute, 24000
Aerial Photo Revised 1975
1975
El Cajon
7.5-minute, 24000
Aerial Photo Revised 1975
1967 Source Sheets
1967
El Cajon
7.5-minute, 24000
Aerial Photo Revised 1966
1967
La Mesa
7.5-minute, 24000
Aerial Photo Revised 1966
1955 Source Sheets
1955
El Cajon
7.5-minute, 24000
Aerial Photo Revised 1953
1948 Source Sheets
1948
EL CAJON
15-minute, 50000
7493604 4 4
page
Topo Sheet Key
This EDR Topo Map Report is based upon the following USGS topographic map sheets. -
1947 Source Sheets
1947
El Cajon
15-minute, 62500
1942 Source Sheets
1942
El Cajon
15-minute, 62500
1939 Source Sheets
1939
El Cajon
15-minute, 62500
1903 Source Sheets
1903
La Jolla
15-minute, 62500
1903
Elcajon
15-minute, 62500
1903
El Cajon
15-minute, 62500
7493604 4 5
page
Topo Sheet Key
This EDR Topo Map Report is based upon the following USGS topographic map sheets. -
1901 Source Sheets
1901
Elcajon
15-minute, 62500
1893 Source Sheets
1893
El Cajon
15-minute, 62500
1893
Elcajon
15-minute, 62500
7493604 4 6
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
2018 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 2018, 7.5-minute
SW, La Mesa, 2018, 7.5-minute
7493604 4 7
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
2015 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 2015, 7.5-minute
SW, La Mesa, 2015, 7.5-minute
7493604 4 8
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
2012 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 2012, 7.5-minute
SW, La Mesa, 2012, 7.5-minute
7493604 4 9
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1996 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 1996, 7.5-minute
7493604 4 10
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1975 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 1975, 7.5-minute
SW, La Mesa, 1975, 7.5-minute
7493604 4 11
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1967 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 1967, 7.5-minute
SW, La Mesa, 1967, 7.5-minute
7493604 4 12
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1955 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 1955, 7.5-minute
7493604 4 13
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1948 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, EL CAJON, 1948, 15-minute
7493604 4 14
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1947 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 1947, 15-minute
7493604 4 15
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1942 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 1942, 15-minute
7493604 4 16
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1939 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 1939, 15-minute
7493604 4 17
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1903 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, Elcajon, 1903, 15-minute
W, La Jolla, 1903, 15-minute
TP, El Cajon, 1903, 15-minute
7493604 4 18
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1901 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, Elcajon, 1901, 15-minute
7493604 4 19
Historical Topo Map
page
SITE NAME:
ADDRESS:
CLIENT:
This report includes information from the
following map sheet(s).
-
W E
SW S SE
NW N NE
1893 0 Miles 0.25 0.5 1 1.5 Not Reported Not Reported SANTEE, CA 92071 Stantec TP, El Cajon, 1893, 15-minute
TP, Elcajon, 1893, 15-minute
7493604 4 20
The EDR Aerial Photo Decade Package
Not Reported Not Reported SANTEE, CA 92071 Inquiry Number: November 10, 20237493604.8 6 Armstrong Road, 4th floor
Shelton, CT 06484
Toll Free: 800.352.0050
www.edrnet.com
2020 1"=500' Flight Year: 2020 USDA/NAIP
2016 1"=500' Flight Year: 2016 USDA/NAIP
2012 1"=500' Flight Year: 2012 USDA/NAIP
2009 1"=500' Flight Year: 2009 USDA/NAIP
2005 1"=500' Flight Year: 2005 USDA/NAIP
2002 1"=500' Acquisition Date: January 01, 2002 USGS/DOQQ 1996 1"=500' Acquisition Date: January 01, 1996 USGS/DOQQ 1994 1"=500' Acquisition Date: January 01, 1994 USGS/DOQQ 1989 1"=500' Flight Date: August 14, 1989 USDA
1985 1"=500' Flight Date: July 29, 1985 USDA
1979 1"=500' Flight Date: January 27, 1979 EDR Proprietary Landiscor 1970 1"=500' Flight Date: March 06, 1970 EDR Proprietary Landiscor 1966 1"=500' Flight Date: November 02, 1966 USGS
1964 1"=500' Flight Date: April 08, 1964 USDA
1953 1"=500' Flight Date: April 14, 1953 USDA
1949 1"=500' Flight Date: February 16, 1949 USDA
EDR Aerial Photo Decade Package 11/10/23 Not Reported Site Name: Client Name: Stantec Not Reported 735 E. Carnegie Drive, Suite 280 SANTEE, CA 92071 SAN BERNARDINO, CA 92408 EDR Inquiry # 7493604.8 Contact: Alicia R Jansen Environmental Data Resources, Inc. (EDR) Aerial Photo Decade Package is a screening tool designed to assist environmental professionals in evaluating potential liability on a target property resulting from past activities. EDR’s professional researchers provide digitally reproduced historical aerial photographs, and when available, provide one photo per decade. Search Results: Year Scale Details Source
When delivered electronically by EDR, the aerial photo images included with this report are for ONE TIME USE ONLY. Further reproduction of these aerial photo images is prohibited without permission from EDR. For more information contact your EDR Account Executive. Disclaimer - Copyright and Trademark Notice Copyright 2023 by Environmental Data Resources, Inc. All rights reserved. Reproduction in any media or format, in whole or in part, of any report or map of Environmental Data Resources, Inc., or its affiliates, is prohibited without prior written permission.
EDR and its logos (including Sanborn and Sanborn Map) are trademarks of Environmental Data Resources, LLC or its affiliates. All other trademarks used herein are the property of their respective owners. 7493604 - 8 page 2 This Report contains certain information obtained from a variety of public and other sources reasonably available to Environmental Data Resources, LLC. It cannot be concluded from this Report that coverage information for the target and surrounding properties does not exist from other sources. This Report is provided on an “AS IS”, “AS AVAILABLE” basis. NO WARRANTY EXPRESS OR IMPLIED IS MADE WHATSOEVER IN CONNECTION WITH THIS REPORT.
ENVIRONMENTAL DATA RESOURCES, LLC AND ITS SUBSIDIARIES, AFFILIATES AND THIRD PARTY SUPPLIERS DISCLAIM ALL WARRANTIES, OF ANY
KIND OR NATURE, EXPRESS OR IMPLIED, ARISING OUT OF OR RELATED TO THIS REPORT OR ANY OF THE DATA AND INFORMATION PROVIDED IN
THIS REPORT, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES REGARDING ACCURACY, QUALITY, CORRECTNESS, COMPLETENESS,
COMPREHENSIVENESS, SUITABILITY, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, NON-INFRINGEMENT, MISAPPROPRIATION, OR OTHERWISE. ALL RISK IS ASSUMED BY THE USER. IN NO EVENT SHALL ENVIRONMENTAL DATA RESOURCES, LLC OR ITS
SUBSIDIARIES, AFFILIATES OR THIRD PARTY SUPPLIERS BE LIABLE TO ANYONE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL,
CONSEQUENTIAL OR OTHER DAMAGES OF ANY TYPE OR KIND (INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS, LOSS OF USE, OR LOSS OF DATA), ARISING OUT OF OR IN ANY WAY CONNECTED WITH THIS REPORT OR ANY OF THE DATA AND INFORMATION PROVIDED IN THIS REPORT.
Any analyses, estimates, ratings, environmental risk levels, or risk codes provided in this Report are provided for illustrative purposes only, and are not intended to provide, nor should they be interpreted as providing any facts regarding, or prediction or forecast of, any environmental risk for any property. Only an assessment performed by a qualified environmental professional can provide findings, opinions or conclusions regarding the environmental risk or conditions in, on or at any property.
7493604.8 2020 = 500'
7493604.8 2016 = 500'
7493604.8 2012 = 500'
7493604.8 2009 = 500'
7493604.8 2005 = 500'
7493604.8 2002 = 500'
7493604.8 1996 = 500'
7493604.8 1994 = 500'
7493604.8 1989 = 500'
7493604.8 1985 = 500'
7493604.8 1979 = 500'
7493604.8 1970 = 500'
7493604.8 1966 = 500'
7493604.8 1964 = 500'
7493604.8 1953 = 500'
7493604.8 1949 = 500'
Not Reported
Not Reported
SANTEE, CA 92071
Inquiry Number: 7493604.5
November 14, 2023
The EDR-City Directory Image Report
6 Armstrong Road
Shelton, CT 06484
800.352.0050
Environmental Data Resources Inc www.edrnet.com
TABLE OF CONTENTS
SECTION
Executive Summary
Findings
City Directory Images
Thank you for your business.
Please contact EDR at 1-800-352-0050
with any questions or comments.
Disclaimer - Copyright and Trademark Notice
This Report contains certain information obtained from a variety of public and other sources reasonably available to Environmental Data Resources, LLC. It cannot be concluded from this Report that coverage information for the target and surrounding properties does not exist from other sources. This Report is provided on an “AS IS”, “AS AVAILABLE” basis. NO WARRANTY EXPRESS OR IMPLIED IS MADE WHATSOEVER IN CONNECTION WITH THIS REPORT. ENVIRONMENTAL DATA
RESOURCES, LLC AND ITS SUBSIDIARIES, AFFILIATES AND THIRD PARTY SUPPLIERS DISCLAIM ALL WARRANTIES, OF
ANY KIND OR NATURE, EXPRESS OR IMPLIED, ARISING OUT OF OR RELATED TO THIS REPORT OR ANY OF THE DATA AND
INFORMATION PROVIDED IN THIS REPORT, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES REGARDING
ACCURACY, QUALITY, CORRECTNESS, COMPLETENESS, COMPREHENSIVENESS, SUITABILITY, MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE, NON-INFRINGEMENT, MISAPPROPRIATION, OR OTHERWISE. ALL RISK IS ASSUMED BY THE USER. IN NO EVENT SHALL ENVIRONMENTAL DATA RESOURCES, LLC OR ITS SUBSIDIARIES,
AFFILIATES OR THIRD PARTY SUPPLIERS BE LIABLE TO ANYONE FOR ANY DIRECT, INCIDENTAL, INDIRECT, SPECIAL,
CONSEQUENTIAL OR OTHER DAMAGES OF ANY TYPE OR KIND (INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS,
LOSS OF USE, OR LOSS OF DATA), ARISING OUT OF OR IN ANY WAY CONNECTED WITH THIS REPORT OR ANY OF THE DATA AND INFORMATION PROVIDED IN THIS REPORT. Any analyses, estimates, ratings, environmental risk levels, or risk codes provided in this Report are provided for illustrative purposes only, and are not intended to provide, nor should they be interpreted as providing any facts regarding, or prediction or forecast of, any environmental risk for any property. Only an assessment performed by a qualified environmental professional can provide findings, opinions or conclusions regarding the environmental risk or conditions in, on or at any property.
Copyright 2023 by Environmental Data Resources, LLC. All rights reserved. Reproduction in any media or format, in whole or in part, of any report or map of Environmental Data Resources, LLC, or its affiliates, is prohibited without prior written permission.
EDR and its logos (including Sanborn and Sanborn Map) are trademarks of Environmental Data Resources, LLC or its affiliates.
All other trademarks used herein are the property of their respective owners.
EXECUTIVE SUMMARY
DESCRIPTION
Environmental Data Resources, Inc.’s (EDR) City Directory Report is a screening tool designed to assist environmental professionals in evaluating potential liability on a target property resulting from past activities.EDR’s City Directory Report includes a search of available business directory data at approximately five year intervals.
RECORD SOURCES
The EDR City Directory Report accesses a variety of business directory sources, including Haines, InfoUSA, Polk,Cole, Bresser, and Stewart. Listings marked as EDR Digital Archive access Cole and InfoUSA records.
The various directory sources enhance and complement each other to provide a more thorough and accurate report.
EDR is licensed to reproduce certain City Directory works by the copyright holders of those works. The purchaser of this EDR City Directory Report may include it in report(s) delivered to a customer.
RESEARCH SUMMARY
The following research sources were consulted in the preparation of this report. A check mark indicates where information was identified in the source and provided in this report.
Year Target Street Cross Street Source
2020 EDR Digital Archive
2017 Cole Information
2014 Cole Information
2010 Cole Information
2005 Cole Information
2000 Cole Information
1995 Cole Information
1992 Cole Information
1986 Haines Criss-Cross Directory
1982 Haines Criss-Cross Directory
1979 Haines Criss-Cross Directory
1975 Haines Criss-Cross Directory
1971 Haines Criss-Cross Directory
7493604- 5 Page 1
FINDINGS
TARGET PROPERTY STREET
Not Reported
SANTEE, CA 92071
Year CD Image Source
PARK CENTER
2020 pg A1 EDR Digital Archive
PARK CENTER DR
2017 pg A2 Cole Information
2014 pg A3 Cole Information
2010 - Cole Information Street not listed in Source
2005 - Cole Information Street not listed in Source
2000 - Cole Information Street not listed in Source
1995 - Cole Information Street not listed in Source
1992 - Cole Information Street not listed in Source
1986 - Haines Criss-Cross Directory Street not listed in Source 1982 - Haines Criss-Cross Directory Street not listed in Source 1979 - Haines Criss-Cross Directory Street not listed in Source 1975 - Haines Criss-Cross Directory Street not listed in Source 1971 - Haines Criss-Cross Directory Street not listed in Source 7493604- 5 Page 2
FINDINGS
CROSS STREETS
No Cross Streets Identified
7493604- 5 Page 3
City Directory Images
-
PARK CENTER
EDR Digital Archive
7493604.5 Page: A1
Target Street Cross Street Source
2020
655 BRIAN PENNINGS
DAVE SPISAK
DAVID LEASK
ERIC GERHARDT
GINA ANDERSON
GWEN HILLEARY
LAKE EVERS
LEI ZHANG
LESLIE COULTER
MARIA HEWETT
MARTHA CAMOU
MARY ESTRADA
PAMELA STERNAMAN
RENE BAHL
SAN DIEGO
VERNIE HILLIGAS
VIOLETA MARTEL
-
PARK CENTER DR
Cole Information
7493604.5 Page: A2
Target Street Cross Street Source
2017
655 COUNTY OF SAN DIEGO
SANTEE HISTORICAL SOCIETY
-
PARK CENTER DR
Cole Information
7493604.5 Page: A3
Target Street Cross Street Source
2014
655 COUNTY OF SAN DIEGO
SANTEE HISTORICAL SOCIETY
Appendix D-1
Preliminary Geotechnical Investigation
Santee 3 Residential Development
PRELIMINARY GEOTECHNICAL INVESTIGATION
SANTEE 3 RESIDENTIAL DEVELOPMENT
APN 181-151-018
SANTEE, CALIFORNIA
Prepared For SANTEE 3 INV, LLC
3121 MICHELSON DRIVE, SUITE 150
IRVINE, CALIFORNIA 92612
Prepared By LEIGHTON AND ASSOCIATES, INC.
3934 MURPHY CANYON ROAD, SUITE B-205
SAN DIEGO, CALIFORNIA 92123
Project No. 11832.002
February 5, 2024
February 5, 2024
Project No. 11832.002
Santee 3 Inv, LLC
3121 Michelson Drive, Suite 150
Irvine, California 92612
Attention: Ms. Karen Alves
Subject: Preliminary Geotechnical Investigation
Santee 3 Development
APN: 181-051-018
Santee, California
In accordance with your request and authorization, we have conducted a preliminary geotechnical investigation of the property for the design and construction of the proposed residential development project. Based on the results of our study, it is our professional opinion that the site is suitable to receive the proposed improvements provided mitigation of the underlying liquefiable soils is implemented prior to construction. The accompanying report presents a summary of our investigation and provides geotechnical conclusions and recommendations relative to the proposed site development.
If you have any questions regarding our report, please do not hesitate to contact this office. We appreciate this opportunity to be of service.
Respectfully submitted,
LEIGHTON AND ASSOCIATES, INC.
Todd Schmitz, CEG 2510 Nicholas Tracy, GE 3058
Senior Project Geologist Associate Engineer
Ext: 8030, [email protected] Ext: 8499, [email protected] Robert Stroh, CEG 2099
Principal Engineering Geologist
Extension: 4090, [email protected]
Distribution: Client via email
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
i
TABLE OF CONTENTS
Section Page
1.0 INTRODUCTION...................................................................................................... 1
1.1 PURPOSE AND SCOPE ............................................................................................. 1
1.2 SITE LOCATION AND DESCRIPTION............................................................................ 2
1.3 PROPOSED DEVELOPMENT ...................................................................................... 2
2.0 SUBSURFACE EXPLORATION AND LABORATORY TESTING.......................... 3
2.1 CURRENT SITE INVESTIGATION................................................................................. 3
2.2 PREVIOUS SITE INVESTIGATION................................................................................ 3
2.3 LABORATORY TESTING ............................................................................................ 4
3.0 SUMMARY OF GEOTECHNICAL CONDITIONS.................................................... 5
3.1 REGIONAL GEOLOGIC SETTING ................................................................................ 5
3.2 SITE-SPECIFIC GEOLOGY ........................................................................................ 5
3.2.1 Quaternary Young Alluvial Flood-Plain Deposits (Qya)................................. 5
3.3 SURFACE AND GROUNDWATER ................................................................................ 5
3.4 GEOLOGIC STRUCTURE ........................................................................................... 6
3.5 ENGINEERING CHARACTERISTICS OF ON-SITE SOILS.................................................. 6
3.5.1 Expansion Potential....................................................................................... 6
3.5.2 Compressible Soils........................................................................................ 6
3.5.3 Soil Corrosivity .............................................................................................. 7
3.5.4 Excavation Characteristics ............................................................................ 7
3.5.5 Infiltration....................................................................................................... 7
4.0 SEISMIC AND GEOLOGIC HAZARDS................................................................. 10
4.1 REGIONAL TECTONIC SETTING AND SEISMICITY....................................................... 10
4.2 LOCAL FAULTING .................................................................................................. 10
4.3 SEISMIC HAZARDS ................................................................................................ 10
4.3.1 Shallow Ground Rupture ............................................................................. 11
4.3.2 Mapped Seismic Hazard Zones .................................................................. 11
4.3.3 Site Class .................................................................................................... 11
4.3.4 Building Code Mapped Spectral Acceleration Parameters.......................... 11
4.4 SECONDARY SEISMIC HAZARDS ............................................................................. 12
4.4.1 Liquefaction and Dynamic Settlement ......................................................... 13
4.4.2 Lateral Spread............................................................................................. 14
4.4.3 Tsunamis and Seiches ................................................................................ 14
4.5 LANDSLIDES ......................................................................................................... 14
4.6 FLOOD HAZARD .................................................................................................... 15
5.0 CONCLUSIONS..................................................................................................... 16 Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
ii
6.0 RECOMMENDATIONS.......................................................................................... 18
6.1 EARTHWORK ........................................................................................................ 18
6.1.1 Site Preparation........................................................................................... 18
6.1.2 Removal of Compressible Soils................................................................... 18
6.1.3 Excavations and Oversize Material ............................................................. 19
6.1.4 Ground Improvement .................................................................................. 20
6.1.5 Engineered Fill ............................................................................................ 21
6.1.6 Earthwork Shrinkage/Bulking ...................................................................... 22
6.1.7 Import Soils ................................................................................................. 22
6.1.8 Expansive Soils and Selective Grading....................................................... 22
6.2 FOUNDATION AND SLAB CONSIDERATIONS .............................................................. 22
6.2.1 Conventional Foundations........................................................................... 23
6.2.2 Drilled Pile Foundations............................................................................... 23
6.2.3 CIDH Pile Installation .................................................................................. 25
6.2.4 Mat Foundations.......................................................................................... 25
6.2.5 Post-Tensioned Foundation Design Recommendations ............................. 26
6.2.6 Foundation Setback .................................................................................... 28
6.2.7 Floor Slabs .................................................................................................. 29
6.3 TEMPORARY EXCAVATIONS.................................................................................... 30
6.4 LATERAL EARTH PRESSURES AND RETAINING WALL DESIGN .................................... 31
6.5 GEOCHEMICAL CONSIDERATIONS ........................................................................... 32
6.6 CONCRETE FLATWORK .......................................................................................... 32
6.7 PRELIMINARY PAVEMENT DESIGN........................................................................... 33
6.8 CONTROL OF GROUND WATER AND SURFACE WATERS............................................ 34
6.9 CONSTRUCTION OBSERVATION .............................................................................. 35
6.10 PLAN REVIEW ................................................................................................... 35
7.0 LIMITATIONS........................................................................................................ 36 TABLES
TABLE 1 – PERCOLATION AND INFILTRATION RATES – PAGE 8
TABLE 2 – 2022 CBC MAPPED SPECTRAL ACCELERATION PARAMETERS – PAGE 12 TABLE 3 – POST-TENSIONED FOUNDATION DESIGN RECOMMENDATIONS - PAGE 27 TABLE 4 – MINIMUM FOUNDATION SETBACK FROM RETAINING WALLS - PAGE 28 TABLE 5 – MAXIMUM SLOPE RATIOS – PAGE 30
TABLE 6 – STATIC EQUIVALENT FLUID WEIGHT (PCF) – PAGE 31 TABLE 7 – PRELIMINARY PAVEMENT SECTIONS – PAGE 33
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
iii
Figures
Figure 1 - Site Location Map Rear of Text
Figure 2 - Geotechnical Map Rear of Text
Figure 3 - Geologic Map Rear of Text
Figure 4 - Regional Fault Map Rear of Text
Figure 5 - Flood Hazard Zone Map Rear of Text
Appendices
Appendix A - References
Appendix B - CPT Test Results and Boring Logs
Appendix C - Laboratory Testing Procedures and Test Results Appendix D - Liquefaction Analyses
Appendix E - General Earthwork and Grading Specifications for Rough Grading Geotechnical-Engineering Report
Geotechnical Services Are Performed for
Specific Purposes, Persons, and Projects
Geotechnical engineers structure their services to meet the specific needs of their clients. A geotechnical-engineering study conducted for a civil engineer may not fulfill the needs of a constructor — a construction contractor — or even another civil engineer. Because each geotechnical- engineering study is unique, each geotechnical-engineering report is unique, prepared solely for the client. No one except you should rely on this geotechnical-engineering report without first conferring with the geotechnical engineer who prepared it. And no one — not even you — should apply this report for any purpose or project except the one originally contemplated.
Read the Full Report
Serious problems have occurred because those relying on a geotechnical-engineering report did not read it all. Do not rely on an executive summary. Do not read selected
elements only.
Geotechnical Engineers Base Each Report on
a Unique Set of Project-Specific Factors
Geotechnical engineers consider many unique, project-specific factors when establishing the scope of a study. Typical factors include: the client’s goals, objectives, and risk-management preferences; the general nature of the structure involved, its size, and configuration; the location of the structure on the site; and other planned or existing site improvements, such as access roads, parking lots, and underground utilities. Unless the geotechnical engineer who conducted the study specifically indicates otherwise, do not rely on a geotechnical-engineering report that was:
• not prepared for you;
• not prepared for your project;
• not prepared for the specific site explored; or
• completed before important project changes were made.
Typical changes that can erode the reliability of an existing geotechnical-engineering report include those that affect:
• the function of the proposed structure, as when it’s changed from a parking garage to an office building, or from a lightindustrial plant to a refrigerated warehouse; • the elevation, configuration, location, orientation, or weight of the proposed structure;
• the composition of the design team; or
• project ownership.
As a general rule, always inform your geotechnical engineer of project changes—even minor ones—and request an
assessment of their impact. Geotechnical engineers cannot accept responsibility or liability for problems that occur because their reports do not consider developments of which they were not informed.
Subsurface Conditions Can Change
A geotechnical-engineering report is based on conditions that existed at the time the geotechnical engineer performed the study. Do not rely on a geotechnical-engineering report whose adequacy may have been affected by: the passage of time; man-made events, such as construction on or adjacent to the site; or natural events, such as floods, droughts, earthquakes, or groundwater fluctuations. Contact the geotechnical engineer before applying this report to determine if it is still reliable. A minor amount of additional testing or analysis could prevent major problems.
Most Geotechnical Findings Are Professional
Opinions
Site exploration identifies subsurface conditions only at those points where subsurface tests are conducted or samples are taken. Geotechnical engineers review field and laboratory data and then apply their professional judgment to render an opinion about subsurface conditions throughout the
site. Actual subsurface conditions may differ — sometimes significantly — from those indicated in your report. Retaining the geotechnical engineer who developed your report to
provide geotechnical-construction observation is the most effective method of managing the risks associated with
unanticipated conditions.
A Report’s Recommendations Are Not Final
Do not overrely on the confirmation-dependent
recommendations included in your report. Confirmationdependent recommendations are not final, because geotechnical engineers develop them principally from
judgment and opinion. Geotechnical engineers can finalize their recommendations only by observing actual subsurface conditions revealed during construction. The geotechnical engineer who developed your report cannot assume
responsibility or liability for the report’s confirmation-dependent recommendations if that engineer does not perform the
geotechnical-construction observation required to confirm the recommendations’ applicability.
A Geotechnical-Engineering Report Is Subject
to Misinterpretation
Other design-team members’ misinterpretation of
geotechnical-engineering reports has resulted in costly Important Information about This
Subsurface problems are a principal cause of construction delays, cost overruns, claims, and disputes.
While you cannot eliminate all such risks, you can manage them. The following information is provided to help. problems. Confront that risk by having your geotechnical engineer confer with appropriate members of the design team after submitting the report. Also retain your geotechnical engineer to review pertinent elements of the design team’s plans and specifications. Constructors can also misinterpret a geotechnical-engineering report. Confront that risk by having your geotechnical engineer participate in prebid and preconstruction conferences, and by providing geotechnical construction observation.
Do Not Redraw the Engineer’s Logs
Geotechnical engineers prepare final boring and testing logs based upon their interpretation of field logs and laboratory data. To prevent errors or omissions, the logs included in a geotechnical-engineering report should never be redrawn for inclusion in architectural or other design drawings. Only photographic or electronic reproduction is acceptable, but recognize that separating logs from the report can elevate risk.
Give Constructors a Complete Report and
Guidance
Some owners and design professionals mistakenly believe they can make constructors liable for unanticipated subsurface conditions by limiting what they provide for bid preparation.
To help prevent costly problems, give constructors the
complete geotechnical-engineering report, but preface it with a clearly written letter of transmittal. In that letter, advise constructors that the report was not prepared for purposes of bid development and that the report’s accuracy is limited; encourage them to confer with the geotechnical engineer who prepared the report (a modest fee may be required) and/ or to conduct additional study to obtain the specific types of information they need or prefer. A prebid conference can also be valuable. Be sure constructors have sufficient time to perform additional study. Only then might you be in a position to give constructors the best information available to you, while requiring them to at least share some of the financial responsibilities stemming from unanticipated conditions.
Read Responsibility Provisions Closely
Some clients, design professionals, and constructors fail to recognize that geotechnical engineering is far less exact than other engineering disciplines. This lack of understanding has created unrealistic expectations that have led to
disappointments, claims, and disputes. To help reduce the risk of such outcomes, geotechnical engineers commonly include a variety of explanatory provisions in their reports. Sometimes labeled “limitations,” many of these provisions indicate where geotechnical engineers’ responsibilities begin and end, to help others recognize their own responsibilities and risks. Read these provisions closely. Ask questions. Your geotechnical engineer should respond fully and frankly.
Environmental Concerns Are Not Covered
The equipment, techniques, and personnel used to perform an environmental study differ significantly from those used to perform a geotechnical study. For that reason, a geotechnicalengineering report does not usually relate any environmental findings, conclusions, or recommendations; e.g., about
the likelihood of encountering underground storage tanks or regulated contaminants. Unanticipated environmental
problems have led to numerous project failures. If you have not yet obtained your own environmental information,
ask your geotechnical consultant for risk-management
guidance. Do not rely on an environmental report prepared for someone else.
Obtain Professional Assistance To Deal
with Mold
Diverse strategies can be applied during building design, construction, operation, and maintenance to prevent
significant amounts of mold from growing on indoor surfaces.
To be effective, all such strategies should be devised for the express purpose of mold prevention, integrated into a comprehensive plan, and executed with diligent oversight by a professional mold-prevention consultant. Because just a small amount of water or moisture can lead to the development of severe mold infestations, many mold- prevention strategies focus on keeping building surfaces dry. While groundwater, water infiltration, and similar issues may have been addressed as part of the geotechnical- engineering study whose findings are conveyed in this report, the geotechnical engineer in charge of this project is not a mold prevention consultant; none of the services performed in connection with the
geotechnical engineer’s study were designed or conducted for the purpose of mold prevention. Proper implementation of the recommendations conveyed in this report will not of itself be sufficient to prevent mold from growing in or on the structure involved.
Rely, on Your GBC-Member Geotechnical Engineer
for Additional Assistance
Membership in the Geotechnical Business Council of the
Geoprofessional Business Association exposes geotechnical engineers to a wide array of risk-confrontation techniques that can be of genuine benefit for everyone involved with a construction project. Confer with you GBC-Member
geotechnical engineer for more information.
8811 Colesville Road/Suite G106, Silver Spring, MD 20910 Telephone: 301/565-2733 Facsimile: 301/589-2017
e-mail: [email protected] www.geoprofessional.org Copyright 2015 by Geoprofessional Business Association (GBA). Duplication, reproduction, or copying of this document, or its contents, in whole or in part, by any means whatsoever, is strictly prohibited, except with GBA’s specific written permission. Excerpting, quoting, or otherwise extracting wording from this document is permitted only with the express written permission of GBA, and only for purposes of scholarly research or book review. Only members of GBA may use this document as a complement to or as an element of a geotechnical-engineering report. Any other firm, individual, or other entity that so uses this document without being a GBA member could be commiting negligent or intentional (fraudulent) misrepresentation.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
1 1.0 INTRODUCTION
We recommend that all individuals utilizing this report read the preceding information sheet prepared by ASFE (the Association of Engineering Firms Practicing in the Geosciences) and the Limitations, Section 7.0, located at the end of this report.
1.1 Purpose and Scope
This report presents the results of our preliminary geotechnical investigation for the undeveloped site located to the North of the San Diego River, to the south and east of Town Center Community Park, and to the west of Chubb Lane in the City of Santee, California (Figure 1). The intent of this report is to provide specific geotechnical conclusions and recommendations for the currently proposed project.
Specifically, our scope of services included:
• Review of available pertinent, published and unpublished geotechnical literature and maps. References cited are listed in Appendix A; • Field reconnaissance of the existing on-site geotechnical conditions; • Subsurface exploration consisting of the excavation, of six cone penetration tests (CPTs). Our previous subsurface exploration at the site (2017) consisted of the excavation of 7 CPT’s. Additionally, three field percolation tests were performed at the site as part of the recent subsurface exploration. The exploration logs and field percolation test data sheets of the current and previously performed exploratory excavations are presented in Appendix B. The approximate exploration locations are shown on Figure 2; • Laboratory testing of representative soil samples obtained from the subsurface exploration program. Results of these tests are provided in Appendix C; • Assessment of geologic hazards;
• Development of seismic design parameters based on the 2022 California Building Code (CBC);
• Compilation and analysis of the geotechnical data obtained from the field investigation and laboratory testing; and
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
2 • Preparation of this report presenting our findings, conclusions, and geotechnical recommendations with respect to the proposed geotechnical design, and general construction considerations.
1.2 Site Location and Description
The site is located as vacant property to the north of the San Diego River, to the south and east of Town Center Community Park, and to the west of Chubb Lane in the City of Santee, California (Figure 1). The site encompasses approximately 22 acres of undeveloped land.
Site topography in general slopes from the north down to the south toward the San Diego River with elevations ranging between approximately 345 feet above mean sea level (msl) to 330 feet msl.
Site Latitude and Longitude
32.8485º N
-116.9751º W
1.3 Proposed Development
We understand that plans for the development of the site are not complete.
Conceptual development for the site is understood to be for multi-family housing construction. Appurtenant improvements may include concrete and asphalt hardscape, utilities, and landscaping. We further understand that grading plans have not yet been developed, however site grades are assumed to not have significant changes from existing elevations. Once conceptual plans with elevations are available, they should be sent to our office so that we can verify that the recommendations provided in our report are still valid with respect to the proposed improvements.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
3 2.0 SUBSURFACE EXPLORATION AND LABORATORY TESTING
2.1 Current Site Investigation
Our recent subsurface exploration of the site was performed on April 24, 2023. We advanced six cone penetration tests (CPTs) to characterize the onsite soils for the purpose of evaluating liquefaction potential. In addition, seven CPTs were advanced during our previous subsurface evaluation performed on October 26, 2017. The purpose of our subsurface exploration was to evaluate the underlying stratigraphy, physical characteristics, and specific engineering properties of the soils within the area of the proposed improvements. Bulk samples of the subgrade soils were collected for laboratory testing and evaluation. After logging, the CPTs were backfilled with bentonite and capped to match the existing finished surface.
The CPT’s were advanced to a maximum depth of approximately 51.5 feet bgs with a truck mounted rig utilizing an integrated, electronic, metal alloy cone.
Subsurface data was obtained at 2.5 cm intervals and in general accordance to ASTM method D 5778. CPT analysis correlates in-situ soil classification behavior to a physical soil classification (by interactions between the CPT cone and soil interface) and is substantiated by a well-studied and accepted soil classification to soil behavior library.
In addition, three percolation tests were excavated to a depth of approximately 3 feet below the existing ground surface. The percolation test well locations were presoaked overnight, and the testing was performed the following day by the falling head method.
The CPT logs and field percolation test results are provided in Appendix B. The approximate exploration locations are depicted on Figure 2.
2.2 Previous Site Investigation
As part of our study, we reviewed one study pertinent to the subject site.
Specifically, we reviewed a report by Law Crandall titled Report of Preliminary Geotechnical Investigation for Rough Grading, Proposed Santee Town Center, Edgemoor Property, dated May 7, 1999. A portion of the field investigation for that report included two borings adjacent to and within this current study area. Field Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
4 exploration locations from that study are shown on Figure 2 and the logs are presented in Appendix B.
2.3 Laboratory Testing
Laboratory testing was performed on representative soil samples to evaluate expansion index and geochemical analysis for corrosion. A discussion of the laboratory tests performed and a summary of the laboratory test results are presented in Appendix C.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
5 3.0 SUMMARY OF GEOTECHNICAL CONDITIONS
3.1 Regional Geologic Setting
The project area is situated in the Peninsular Ranges Geomorphic Province of California. This geomorphic province encompasses an area that extends approximately 900 miles from the Transverse Ranges and the Los Angeles Basin south to the southern tip of Baja California, and varies in width from approximately 30 to 100 miles (Norris and Webb, 1990). The province is characterized by mountainous terrain on the east composed mostly of Mesozoic igneous and metamorphic rocks, and relatively low-lying coastal terraces to the west underlain by late Cretaceous-age, Tertiary-age, and Quaternary-age sedimentary units.
Most of the coastal region of the County of San Diego, including the site, occurs within this coastal region and is underlain by sedimentary units. More locally, the site generally consists of alluvial soils underlain at depth by granitic bedrock.
3.2 Site-Specific Geology
Based on our subsurface exploration and review of geologic literature and maps (Appendix A), the geologic units underlying the property consist of Quaternaryaged Young Alluvial Floodplain Deposits. The approximate aerial distributions of those units are shown on the Geotechnical Map (Figure 3). A brief description of the geologic units encountered on the site is presented below.
3.2.1 Quaternary Young Alluvial Flood-Plain Deposits (Qya) Holocene-aged Young Alluvial Flood-Plain Deposits underlie the entire site.
As encountered, the young alluvial flood-plain deposits consist of interbedded zones of unconsolidated silty sand and sandy silt with varying amounts of gravel. It should be noted that the CPT’s encountered refusal on very dense gravel and potentially granitic materials at depths ranging from approximately 25 to 51 feet bgs.
3.3 Surface and Groundwater
Groundwater was observed in Boring 5-1 by others (Law Crandall, 1999) at 13 feet below the ground surface (bgs); i.e. 331 feet mean sea level (msl). In general, the depth to groundwater is anticipated to correspond to the water level within the adjacent San Diego River. It should be noted that perched groundwater levels Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
6 may develop and fluctuate during periods of precipitation or increased landscape irrigation. We anticipate that conventional foundations will be located above the existing static groundwater table at the site. However, it should be noted that any deep foundations will likely encounter groundwater underlying the site.
3.4 Geologic Structure
The site is located to the north of the San Diego River. Based on our recent subsurface exploration, the project site is underlain by compressible and potentially liquefiable soils. Recommendations to mitigate the potential liquefaction and associated dynamic settlement are provided in this report.
3.5 Engineering Characteristics of On-site Soils
Based on the results of our laboratory testing of representative on-site soils, and our professional experience on similar sites with similar soils conditions, the engineering characteristics of the on-site soils are discussed below.
3.5.1 Expansion Potential
Based on our visual observations performed during our site reconnaissance, subsurface investigation, laboratory testing, and similar projects in the site vicinity, we anticipate the near surface soils to have a generally very low expansion potential. However, soils with greater expansion potential may be encountered during grading and additional testing may be warranted. Nevertheless, expansive soils are not anticipated to impact the proposed site development.
3.5.2 Compressible Soils
Based on the results of our subsurface explorations at the site, and review of previous geotechnical explorations, the site is underlain by alluvial deposits which are considered compressible. These soils are not considered suitable for support of foundation loads in their present condition. Recommendations for ground improvement of these soils are provided in Section 6 of this report.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
7 3.5.3 Soil Corrosivity
A preliminary corrosive soil screening for the on-site materials was completed to evaluate their potential effect on concrete and ferrous metals.
The corrosion potential was evaluated using the results of laboratory testing on one representative soil sample obtained during our subsurface evaluation.
Laboratory testing was performed to evaluate pH, minimum electrical resistivity, and chloride and soluble sulfate content. The sample tested had maximum measured pH value of 7.1, and a measured minimum electrical resistivity of 12,100 ohm-cm. Test results also indicated that the sample had a chloride content of 10 parts per million (ppm), and a soluble sulfate content of less than 150 ppm.
3.5.4 Excavation Characteristics
The site is underlain by Young Alluvial Floodplain Deposits generally consisting of silty to clayey sands with gravel. With regards to the proposed project, it is anticipated these on-site soils can be excavated with conventional heavy-duty construction equipment. Oversize cobble material, if encountered, should be placed in non-structural areas or hauled off-site.
3.5.5 Infiltration
Field percolation tests were performed during our investigation in general accordance with the County of San Diego BMP Design Manual (2020).
Based on our field percolation testing, the in-situ percolation rates and calculated infiltration rates at tested locations and depths are summarized in Table 2 below. It should be noted that we have used the following equation based upon the Porchet Method to convert measured percolation rates to infiltration rates in accordance with County of San Diego Standards. In addition, we have included a recommended infiltration rate with a minimum factor of safety of 2 for the preliminary design of potential infiltration systems:
It = H * 60 * r
t(r+2HAVG)
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
8 Where:
It = calculated infiltration rate, inches/hour
H = change in head over the time interval, inches
t = time interval, minutes
r = radius of test hole
HAVG = average head over the time interval, inches
The field percolation test locations are shown on the Geotechnical Map (Figur 2). Field data and measured percolation rates are presented in Appendix B.
Table 1. Percolation and Infiltration Rates
Test No. Depth
(ft) Soil Type
Measured
Percolation
Rate
(mins/in)
Calculated
Infiltration
Rate
(inches/hr)
Recommended
Infiltration
Rate w/ FS of 2
(inches/hr)
P-1 3.0 SM 1.1 2.35 1.17
P-2 3.0 SM 0.95 3.04 1.52
P-3 3.0 SM 1.0 2.86 1.43
Based on the field percolation testing, the tested locations are categorized as “Partial Infiltration” conditions. Design of proposed infiltration basins should account for the shallow groundwater table which presents a potential for mounding and an appropriate factor of safety should be applied to the above infiltration rates to account for the vertical separation to the groundwater table. In addition, design of the basins should also consider the proximity of the San Diego River to ensure downstream water rights are not violated.
It is important to note that percolation rates are not equal to infiltration rates.
As a result, we have made a distinction between percolation rates where water movement is considered laterally and vertically versus infiltration rates where only the vertical direction is considered. It should also be noted that the above percolation test results are representative of the tested locations and depths where they were performed, and that percolation test field measurements are accurate to 0.01 feet. Varying subsurface Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
9 conditions may exist outside of the test locations, which could alter the calculated percolation rate indicated below.
It is also possible that the long-term rate of transmissivity of permeable soil strata may be lower than the values obtained by testing. Infiltration may be influenced by a combination of factors including but not limited to a highly variable vertical permeability and limited lateral extent of permeable soil strata, a reduction of permeability rates over time due to silting of the soil pore spaces, and other unknown factors. Accordingly, the possibility of future surface ponding of water, as well as shallow groundwater impacts on subterranean structures such as basements and underground utilities should be anticipated as possible future conditions in all design aspects of the site.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
10 4.0 SEISMIC AND GEOLOGIC HAZARDS
4.1 Regional Tectonic Setting and Seismicity
The site is located within the Peninsular Ranges Geomorphic Province, which is traversed by several major active faults. The Whittier-Elsinore, San Jacinto, and the San Andreas faults are major active fault systems located east of the site, and the Rose Canyon, Newport-Inglewood (offshore), and Coronado Bank are active faults located west to southwest of the site (Jennings, 2010).
The Rose Canyon fault zone consists predominantly of right-lateral strike-slip faults that extend south-southeast bisecting the San Diego metropolitan area. Various fault strands display strike-slip, normal, oblique, or reverse components of displacement. The Rose Canyon fault zone extends offshore at La Jolla and continues north-northwest subparallel to the coastline. The offshore segments are poorly constrained regarding location and character. South of downtown, the fault zone splits into several splays that underlie San Diego Bay, Coronado, and the ocean floor south of Coronado (Treiman, 1993 and 2000; Kennedy and Clarke, 1999). Portions of the fault zone in the Mount Soledad, Rose Canyon, and downtown San Diego areas have been designated by the State of California (CGS, 2021) as being Earthquake Fault Zones.
4.2 Local Faulting
The California Geologic Survey (CGS, 2018) defines a Holocene-active fault as a fault which has “had surface displacement within Holocene time (about the last 11,700 years).” Our review of available geologic literature (Appendix A) indicates that there are no known pre-Holocene or Holocene-active faults transecting the site.
The site is also not located within any State mapped Earthquake Fault Zones or County of San Diego mapped fault zones. The nearest active fault is the Rose Canyon fault zone located approximately 14.0 miles southwest of the site (USGS, 2008).
4.3 Seismic Hazards
Severe ground shaking is most likely to occur during an earthquake on one of the regional active faults in Southern California that are mentioned above. The effect Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
11 of seismic shaking may be mitigated by adhering to the California Building Code or state-of-the-art seismic design parameters of the Structural Engineers Association of California.
4.3.1 Shallow Ground Rupture
As mentioned above, no pre-Holocene or Holocene-active faults are mapped crossing or projecting toward the site. Due to the absence of faults at the site, surface rupture from faulting is considered low.
4.3.2 Mapped Seismic Hazard Zones
The site is not located within a State mapped Earthquake Fault Zone (EFZ), nor is it located within a County of San Diego fault zone.
4.3.3 Site Class
Utilizing 2022 California Building Code (CBC) procedures, we have characterized the site soil profile to be a Site Class D based on our experience with similar sites in the project area and the results of our subsurface evaluation. It should be noted, per Section 11.4.8 of ASCE 7- 16, a ground motion hazard analysis shall be performed in accordance with Section 21.2 for structures having a fundamental period of vibration greater than 0.5s on Site Class D sites where S1 is greater than or equal to 0.2g.
However, although S1 is greater than 0.2g at the site, it is anticipated that the proposed residential structures will have a fundamental period of vibration of less than 0.5s based on our current understanding. Therefore, a site-specific ground motion analysis is assumed to be not required according to ASCE 7-16 Section 11.4.8; however, the project structural engineer needs to confirm this assumption.
4.3.4 Building Code Mapped Spectral Acceleration Parameters The effect of seismic shaking may be mitigated by adhering to the California Building Code and state-of-the-art seismic design practices of the Structural Engineers Association of California. Provided in Table 2 are the spectral acceleration parameters for the project determined in accordance with the 2022 CBC (CBSC, 2022) and SEAOC/OSHPD Seismic Design Maps Web Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
12 Application (2020). Since the site has an S1 value greater than 0.2g and site specific ground motion hazard analysis has not been performed, increased values of Cs are required for analysis as summarized in EXCEPTION 2 of ASCE 7-16 Section 11.4.8.
Table 1 - 2022 CBC Mapped Spectral Acceleration Parameters Site Class D
Site Coefficients
Fa
Fv
=
=
1.192
2.034
Mapped MCE Spectral Accelerations
SS
S1
=
=
0.769g
0.283g
Site Modified MCE Spectral Accelerations
SMS
SM1
=
=
0.917g
0.576g
Design Spectral Accelerations
SDS
SD1
=
=
0.612g
0.384g
If the requirements of EXCEPTION 2 are found to be a significant design constraint, we recommend using the shear wave velocity measurements be at the site for use in performing site specific ground motion analysis.
Utilizing ASCE Standard 7-16, in accordance with Section 11.8.3, the following additional parameters for the peak horizontal ground acceleration are associated with the Geometric Mean Maximum Considered Earthquake (MCEG). The mapped MCEG peak ground acceleration (PGA) is 0.33g for the site. For a Site Class D, the FPGA is 1.27 and the mapped peak ground acceleration adjusted for Site Class effects (PGAM) is 0.419g for the site.
4.4 Secondary Seismic Hazards
In general, secondary seismic hazards can include soil liquefaction, seismicallyinduced settlement, lateral displacement, surface manifestations of liquefaction, landsliding, seiches, and tsunamis. The potential for secondary seismic hazards at the subject site is discussed below.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
13 4.4.1 Liquefaction and Dynamic Settlement
Liquefaction and dynamic settlement of soils can be caused by strong vibratory motion due to earthquakes. Granular soils tend to densify when subjected to shear strains induced by ground shaking during earthquakes.
Research and historical data indicate that loose granular soils underlain by a near surface ground water table are most susceptible to liquefaction, while the most clayey materials are not susceptible to liquefaction. Liquefaction is characterized by a loss of shear strength in the affected soil layer, thereby causing the soil to behave as a viscous liquid. This effect may be manifested at the ground surface by settlement and, possibly, sand boils where insufficient confining overburden is present over liquefied layers. Where sloping ground conditions are present, liquefaction-induced instability can result.
The project site is underlain by unconsolidated sandy materials with a groundwater table at approximately 13 feet bgs. These subsurface conditions present a potential for liquefaction. Therefore, we performed a liquefaction analysis utilizing the computer program CLiq Version 1.7.6.34, considering the Maximum Considered Earthquake event with a mean magnitude M6.4 (i.e., associated with the Design Earthquake Ground Motion). The analysis considered the mapped peak ground acceleration adjusted for Site Class effects (PGAM) of 0.42g. Based on the results of the liquefaction analysis, several discontinuous and variable thickness liquefiable layers of saturated alluvial materials are considered susceptible to liquefaction at the design earthquake ground motion.
Total dynamic settlement at the site as a result of the Design Earthquake Ground Motion is roughly estimated at between approximately 0.9 to 7.1 inches. Differential dynamic settlement at the site is anticipated to be on the order of 4 inches over 50 feet considering the depth and nature of the liquefied zones. A summary plot showing idealized profile, relevant CPT data, calculated cyclic stress and resistance ratio, factor of safety, and liquefaction-induced settlement is provided in Appendix D.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
14 4.4.2 Lateral Spread
Empirical relationships have been derived (Youd et al., 1999) to estimate the magnitude of lateral spread due to liquefaction. These relationships include parameters such as earthquake magnitude, distance of the earthquake from the site, slope height and angle, the thickness of liquefiable soil, and gradation characteristics of the soil.
The susceptibility to earthquake-induced lateral spread is considered to be moderate for the site because of the nature of the underlying liquefiable layers and sloping topography of the bank of the adjacent San Diego River.
The potential for lateral spread was evaluated using the computer program CLiq Version 1.7.6.34, considering the Maximum Considered Earthquake event with a mean magnitude M6.4 and the mapped peak ground acceleration adjusted for Site Class effects (PGAM) of 0.42g. Based on our analysis, lateral spreading of up to approximately 30 inches could occur due to a design-level earthquake. Lateral spreading can be mitigated through implementation of a recommended ground improvement program covered in Section 6 of this report.
4.4.3 Tsunamis and Seiches
Based upon the California Emergency Management Agency Tsunami Inundation Map (CalEMA, 2009), the site is not located within a tsunami inundation area. In addition, based on the generally strike-slip character of off-shore faulting and proposed elevation of the site with respect to sea level, the possibility of seiches and/or tsunamis is considered to be low.
4.5 Landslides
Several formations within the San Diego region are particularly prone to landsliding. These formations generally have high clay content and mobilize when they become saturated with water. Other factors, such as steeply dipping bedding that project out of the face of the slope and/or the presence of fracture planes, will also increase the potential for landsliding.
No landslides or indications of deep-seated landsliding were indicated at the site during our field exploration or our review of available geologic literature, Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
15 topographic maps, and stereoscopic aerial photographs. Therefore, the potential for significant landslides or large-scale slope instability at the site is considered low.
4.6 Flood Hazard
According to a Federal Emergency Management Agency (FEMA) flood insurance rate map (FEMA, 2023); portions of the site are located within the 100-Year Flood Plain (Figure 5). Based on this review and our site reconnaissance, the potential for flooding of the site is considered moderate. Planning for development of the site should consider raising grades in the potential flood zones.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
16 5.0 CONCLUSIONS
Based on the results of our geotechnical investigation of the site, it is our opinion that the proposed development is feasible from a geotechnical standpoint, provided the following conclusions and recommendations are incorporated into the project plans and specifications.
• Generally loose surficial soils consisting of alluvium underlie the site and are considered compressible. Therefore, in their present condition, these soils are not considered suitable for the support of structural loads or the support of engineered fill soils and settlement sensitive site improvements. Section 6.1.2 of this report provides specific recommendations regarding mitigation of these soil materials. • The underlying alluvial deposits to depths of up approximately 51 feet are subject to localized liquefaction, seismic settlement, and lateral spreading. Total dynamic settlement at the site as a result of the Design Earthquake Ground Motion is roughly estimated at between approximately 0.9 to 7.1 inches. Differential dynamic settlement at the site is anticipated to be on the order of 4 inches over 50 feet considering the depth and nature of the liquefied zones. Lateral spreading up to approximately 30 inches is also anticipated. The potential for seismic settlement and lateral spreading can be mitigated by following the recommendations provided in Section 6 of this report.
• Based on the results of our subsurface explorations and available geologic references, groundwater is not anticipated to be a constraint during site construction, and we do not anticipate that temporary dewatering will be necessary. However, at the time of a previous field investigation by others, groundwater was observed in 13 feet below the ground surface (bgs); i.e. 331 feet mean sea level (msl). Groundwater depth is anticipated to correspond to the water level of the adjacent San Diego River. It should be noted that groundwater will be encountered during the construction of ground improvements.
• Based on the results of our subsurface investigation, we anticipate that the onsite materials should be generally rippable with conventional heavy-duty earthwork equipment. The existing onsite soils are suitable for reuse as engineered fill provided they are relatively free of organic material, debris, and rock fragments larger than 6 inches in maximum dimension.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
17 • Based on laboratory testing, materials derived from the on-site soil materials possess a very low expansion potential, although locally more expansive materials may be encountered.
• Although Leighton does not practice corrosion engineering, laboratory test results indicate the soils present on the site have a negligible potential for sulfate attack on normal concrete. The onsite soils are not considered to be corrosive to buried uncoated ferrous metals.
• Based on the results of our geotechnical study, the site is considered to be a “Partial Infiltration” site. BMP design should consider depth to ground water and the proximity to the adjacent San Diego River.
• Portions of the site are located within a zone mapped as a 100-Year Flood Plain.
Planning of the site should consider raising the grades within these portions above the flood elevation.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
18 6.0 RECOMMENDATIONS
Plans for the development of the site were not available at the time of this report. Once grading and structural plans are complete, they should be sent to our office so that we can verify that the recommendations provided in our report are still valid with respect to the proposed improvements. Based on our geotechnical evaluation, the primary geotechnical concern at the site is the existing compressible undocumented fill and alluvial materials which are susceptible to seismically induced liquefaction in their current condition.
Remediation of the potential for static and seismic settlements include performing ground improvement, deep foundations, or mat foundations designed to accommodate differential settlement in accordance with 2022 CBC and ASCE 7-16. General recommendations for these approaches are provided in the following sections.
6.1 Earthwork
We anticipate that earthwork at the site will consist of site preparation, excavation and fill operations, and ground improvement. We recommend that earthwork on the site be performed in accordance with the following recommendations and the General Earthwork and Grading Specifications for Rough Grading included in Appendix E. In case of conflict, the following recommendations supersede those in Appendix E.
6.1.1 Site Preparation
Prior to grading, all areas to receive structural fill, engineered structures, or hardscape should be stripped of vegetation and cleared of surface and subsurface obstructions, including any existing debris and undocumented, loose, compressible, or unsuitable soils. Removed vegetation and debris should be properly disposed off site. All areas to receive fill and/or other surface improvements should be scarified to a minimum depth of 8 inches, brought to optimum or above-optimum moisture conditions, and recompacted to at least 90 percent relative compaction based on ASTM Test Method D1557.
6.1.2 Removal of Compressible Soils
Potentially compressible undocumented fill and surficial alluvial soils at the site may settle as a result of wetting or settle under the surcharge of Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
19 engineered fill and/or structural loads supported on conventional foundations. These soils should be removed to a minimum depth of 2 feet below bottom of foundation footings. The lateral limits of the removal bottom should extend a length equal to the removal depth where possible.
If the recommended lateral removal limits cannot be accommodated, temporary shoring or slot removals may be necessary. The bottom of all removals should be evaluated by a Certified Engineering Geologist to confirm conditions are as anticipated. Note that deeper alluvial soils are compressible as well. Section 6.1.4 of this report provides specific recommendations regarding mitigation of seismic settlement using ground improvement for the deeper alluvial soils.
In areas of proposed pavements, hardscape and landscaping features, removals should be performed to a depth of 2 feet below proposed subgrade elevation and extend at least 2 feet beyond the limits of the proposed improvements. The bottom of all removals should be evaluated by a Certified Engineering Geologist to confirm conditions are as anticipated.
In general, the soil that is removed may be reused and placed as engineered fill provided the material is moisture conditioned to above optimum moisture content, and then recompacted prior to additional fill placement or construction. Soil with an expansion index greater than 50 should not be used within 5 feet of finish grade in the building pad. The actual depth and extent of the required removals should be confirmed during grading operations by the geotechnical consultant.
6.1.3 Excavations and Oversize Material
Excavations of the onsite materials may generally be accomplished with conventional heavy-duty earthwork equipment. Due to the generally friable nature of the fill and alluvium, temporary excavations, such as utility trenches with vertical sides, may slough over time.
In accordance with OSHA requirements, excavations deeper than 5 feet should be shored or be laid back if workers are to enter such excavations.
Temporary sloping gradients should be determined in the field by a “competent person” as defined by OSHA. For preliminary planning, sloping Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
20 of fill soils at 1:1 (horizontal to vertical) may be assumed. Excavations supporting structures greater than 20 feet in height will require an alternative sloping plan or shoring plan prepared by a California registered civil engineer.
6.1.4 Ground Improvement
The alluvial soils are considered compressible and susceptible to seismically induced settlement resulting from potential liquefaction in their current condition. Ground improvement is recommended beneath the proposed structures to help densify the soils and improve bearing capacity where shallow foundations are planned and do not meet the thresholds for ASCE 7-16 Section 12.13. Various methods of ground improvement may be considered for the site; including stone columns, deep soil mixing, rammed aggregate piers, and compaction grouting. The selection of the appropriate ground improvement method should be based on demands of the proposed improvements, the proximity of nearby buildings and structures, and general logistics and/or limitations associated with each method.
We recommend that a site-specific ground improvement plan be drafted by a specialty contractor that will contain the location of ground improvement including design diameter and spacing. The ground improvement program should be designed with the goal of mitigating liquefaction and reducing anticipated settlements to a level that is acceptable to the project structural engineer. The plan should include the ground improvement installation equipment and specifications for the materials being used (i.e. aggregate, cement). Based on the results of the CPTs, ground improvement depths are anticipated to extend to depths ranging from approximately 43 to 51 feet bgs.
Note that the proposed ground improvement may be terminated a few feet below the bottom of the foundation level. The cutoff elevation should allow placement of a minimum of 2 feet of engineered/compacted fill immediately below the foundation level. The onsite soil or concrete generated from the demolition of the existing buildings may be used as fill. If the onsite concrete is used, the gradation of the crushed concrete should conform to the gradation of Caltrans Crushed Miscellaneous Base.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
21 A field verification program using CPTs is recommended to provide data to estimate the post ground improvement settlement. CPTs should be used prior to placement of ground improvement and following ground improvement. If the total static and seismic settlement after ground improvement is determined to be greater than 1.5 inches, a mat foundation may be required. Otherwise, conventional foundations may be used. Field verification procedures should be reviewed by and be acceptable to the Geotechnical Engineer.
In addition, a field test or trial installation program is recommended to verify the ground improvement success (i.e., verified by ASTM D1586 (SPT) and/or ASTM D3441 (CPT)). Field test or trial installation procedures should be reviewed by and be acceptable to the Geotechnical Engineer.
6.1.5 Engineered Fill
In areas proposed to receive engineered fill, the existing upper 8 inches of subgrade soils should be scarified then moisture conditioned to moisture content at or above the optimum content and compacted to 90 percent or more relative to the maximum laboratory dry density, as evaluated by ASTM D 1557. Soil materials utilized as fill should be free of oversized rock, organic materials, and deleterious debris. Rocks greater than 6 inches in diameter should not be placed within 2 feet of finished grade. Fill should be moisture conditioned to at least 2 percent above the optimum moisture content and compacted to 90 percent or more relative to the maximum laboratory dry density, as evaluated by ASTM D 1557. Although the optimum lift thickness for fill soils will be dependent on the type of compaction equipment utilized, fill should generally be placed in uniform lifts not exceeding approximately 8 inches in loose thickness.
In vehicle pavement and trash enclosure areas the upper 12 inches of subgrade soils should be scarified then moisture conditioned to a moisture content above optimum content and compacted to 95 percent or more relative to the maximum laboratory dry density, as evaluated by ASTM D 1557.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
22 Placement and compaction of fill should be performed in general accordance with current County of San Diego grading ordinances, California Building Code, sound construction practice, these recommendations and the General Earthwork and Grading Specifications for Rough Grading presented in Appendix E.
6.1.6 Earthwork Shrinkage/Bulking
The volume change of excavated onsite materials upon recompaction as fill is expected to vary with material and location. Typically, the surficial soils vary significantly in natural and compacted density, and therefore, accurate earthwork shrinkage/bulking estimates cannot be determined. However, based on our experience, a 5 to 10 percent shrinkage factor is considered appropriate for the alluvium at the site.
6.1.7 Import Soils
If import soils are necessary to bring the site up to the proposed grades, these soils should be granular in nature, environmentally clean, have an expansion index less than 50 (per ASTM Test Method D4829) and have a low corrosion impact to the proposed improvements. Import soils and/or the borrow site location should be evaluated by the geotechnical consultant prior to import.
6.1.8 Expansive Soils and Selective Grading
Based on our laboratory testing and observations, we anticipate the onsite soil materials possess a very low expansion potential (Appendix C).
Selective grading to provide low expansion materials below foundations is not anticipated.
6.2 Foundation and Slab Considerations
At the time of drafting this report, foundation loads and types were not known.
Recommendations for various foundation systems are provided for structural engineering consideration. These recommendations assume that the soils encountered within 5 feet of pad grade have a low potential for expansion (EI<50).
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
23 If more expansive materials are encountered and selective grading cannot be accomplished, revised foundation recommendations may be necessary.
6.2.1 Conventional Foundations
Proposed structures may be supported by spread footings founded in properly compacted engineered fill if underlain by properly compacted engineered fill in accordance with Section 6.1.5 and ground improvement has been performed. Footings should extend a minimum of 24 inches beneath the lowest adjacent finish subgrade. At these depths, footings may be designed for a maximum allowable (FS >3) bearing pressure of 3,000 pounds per square foot. This capacity may also be increased by 500 psf per each additional foot of embedment up to a maximum of 4,000 psf. The allowable pressures may be increased by one-third when considering loads of short duration such as wind or seismic forces. The minimum recommended width of footings is 18 inches for continuous footings and 24 inches for square or round footings. Continuous footings should be designed in accordance with the structural engineer’s requirements and have a minimum reinforcement of four No. 5 reinforcing bars (two top and two bottom). Reinforcement of individual column footings should be per the structural requirements.
The recommended allowable-bearing capacity is based on a maximum total settlement of 1 inch and a differential of 3/4-inch. Since settlement is a function of footing size and contact bearing pressures, some differential settlement can be expected where a large differential loading condition exists. The settlement estimates assume that ground improvement has been performed.
6.2.2 Drilled Pile Foundations
As an alternative to performing ground improvement within building areas, deep foundations may be used for structural support. The piles should extend at least 2 feet into competent bedrock materials which are estimated at depths ranging from approximately 43 to 51 feet bgs. The foundation depths will need to be further evaluated by the geotechnical consultant and structural engineer during the design based on anticipated axial and lateral loading.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
24 Due to the potential for caving soils, liquefaction, and downdrag, we recommend the piles be constructed with a smooth permanent casing to below the zone of the anticipated liquefiable layers. Based on the information from our CPTs, this zone ranges from the surface to approximately 20 to 43 feet bgs. Note that the proposed grades will change and the structure locations are currently unknown so further coordination between the structural engineer and geotechnical engineer will be required.
For preliminary analysis and development of the vertical capacity of CIDH friction piles, an allowable skin friction of 200 psf and 400 psf may be utilized for the alluvial and bedrock materials, respectively.
Static pile settlement is anticipated to be less than ¾-inch under design loads and normal service conditions where capacity is based solely on pile skin friction. The design skin friction is based on center-to-center pile spacing of at least 3 pile diameters. Where piles are spaced more closely, a reduction in pile capacity is necessary unless post-grouting is used (micropiles). Construction of piles should be sequenced such that the concrete of constructed piles is allowed to setup prior to construction of piles within 5 diameters.
To resist lateral loads, if any, CIDH piles can be designed in accordance with Section 1807.3 of the 2022 CBC. For level ground conditions, we recommend lateral soil bearing pressures determined from Table 1806.2 of 150 psf per foot of depth below the finish grade be used for determination of parameters S1 and S3, in the Non-constrained and Constrained design criteria, respectively. These pressures assume piles spaced at least eight diameters center-to-center. Where sloping ground is present or piles are more closely spaced, revised parameters should be provided. No increase for short term lateral loading is recommended. For seismic conditions, lateral resistance from the liquefied layers should be neglected. Once grades and structure locations are known, the elevations of the layers to neglect can be provided.
In addition to resistance to lateral loads induced in the structure from seismic shaking, lateral slope displacement is also a consideration for the piles. Lateral displacement of up to 30 inches may be experienced at the site as a result of the modal MCEG event. Piles subjected to lateral Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
25 displacement should be designed to comply with the requirements of Section 12.13.9.3.4 of ASCE 7-16.
6.2.3 CIDH Pile Installation
All CIDH pile installation should be performed under the observation of the geotechnical consultant and consistent with standard practice. Drilling equipment should be powerful enough to drill through the young alluvium materials and underlying bedrock to the design penetration depths. Once a pile excavation has been started, construction should be completed within 8 hours, which includes inspection, placement of the reinforcement, and placement of the concrete.
Caving of friable, soft or loose soils may occur where open excavations are made. Therefore, a temporary starter casing may be considered to protect the top of the borehole to mitigate caving conditions. In addition, the specialty contractor should also be prepared to employ casing or other methods of advancing the drilled pile excavation to mitigate caving, if needed. Use of temporary casing should be at the contractor’s discretion.
To the extent practical within saturated conditions, loose materials should be removed from the bottom of the pile excavation prior to concrete placement.
If pile excavations become bell-shaped and cannot be advanced due to severe caving, the caved region may be filled with a sand/cement slurry and redrilled. Redrilling may continue when the slurry has reached suitable set and strength. In this case, it may be prudent to utilize casing or other special methods to facilitate continued drilling after the slurry has set.
6.2.4 Mat Foundations
The proposed structures may also be founded on a mat foundation provided the differential settlement thresholds of ASCE 7-16 are met. Mat foundations should be supported on properly compacted fill material using a static allowable bearing capacity not to exceed 2,500 pounds per square foot. This value may be increased by one-third for short-term wind or seismic loads. Based on our experience, local static and seismic bearing pressures below the mat may exceed these values and should be reviewed Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
26 by the geotechnical consultant. Thickness and reinforcement of the mat foundation should be in accordance with the design of the project structural engineer. The mat should be founded within properly compacted fill prepared in accordance with the earthwork recommendations provided herein. If any of the soils exposed at foundation grades are disturbed during the excavation process, they should be excavated to suitable materials.
Mat foundations typically experience some deflection due to loads placed and the reaction of the soils underlying the foundations. A design coefficient of subgrade reaction of K1, of 150 pounds per cubic inch (pci) may be used for evaluating such deflections at the site. This value is based on support by engineered fill soils and is considered as applied to a unit square foot area. The value should be adjusted for the design foundation size. The coefficient of subgrade reaction Kb for a footing of specific width may be evaluated using the following equation.
Kb = K1 [(b+1)/2b]2
where b is the least width of the foundation in feet
Based on our preliminary evaluation and the net increase in the effective stress on the foundation soils, the anticipated total settlement for a mat foundation should be less than approximately ½-inch. Anticipated maximum differential settlements of approximately 50 percent of the total settlement will likely occur between the most heavily loaded areas of the structure and the areas supporting the lightest loads. More detailed analysis to evaluate total and differential settlement should be carried out by the structural engineer and reviewed by this office after bearing pressures are determined.
6.2.5 Post-Tensioned Foundation Design Recommendations
For post-tensioned foundations, we recommend using the geotechnical parameters presented in table below and criteria of the 2022 California Building Code and the Third Edition of Post-Tension Institute Manual. The parameters provided are based on subgrade soils with a low expansion potential (EI<50). A post-tensioned foundation system designed and constructed in accordance with these recommendations is expected to be Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
27 structurally adequate for the support of the at-grade residential buildings provided our recommendations for ground improvement are implemented.
Based on an evaluation of the anticipated post ground improvement settlement, Table 3 presents the recommended post-tension foundation design parameters.
Table 3 – Minimum Foundation Setback
Design Criteria At-Grade Residential Building
Edge
Moisture
Variation, em
Center Lift: 9.0 feet
Edge Lift: 4.8 feet
Differential
Swell, ym
Center Lift: 0.46 inches
Edge Lift: 0.65 inches
Perimeter Footing Depth: 24 inches
Allowable Bearing Capacity 2,500 psf
The post-tensioned (PT) foundation and slab should also be designed in accordance with structural considerations. For a PT foundation, the concrete slabs section should be at least 5 inches thick. Continuous footings (ribs or thickened edges) with a minimum width of 12 inches and a minimum depth of 24 inches below lowest adjacent soil grade may be designed for a maximum allowable bearing pressure of 2,500 pounds per square foot. For a uniform thickness “mat” PT foundation, the perimeter cut off wall should be at least 8 inches below the lowest adjacent grade.
However, note that where a foundation footing or perimeter cut off wall is within 3 feet (horizontally) of adjacent drainage swales, the adjacent footing should be embedded a minimum depth of 12 inches below the swale flow line. The allowable bearing capacity may be increased by one-third for short-term loading. For post-tension foundation, the anticipated maximum total and differential static settlement is 1-inch and ¾-inch, respectively, based on a successful ground improvement program.
The PT slab should be underlain by a moisture barrier consisting of 2 inches sand over a 10-mil plastic sheeting over 2 inches of sand. Note that Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
28 moisture barriers can retard, but not eliminate moisture vapor movement from the underlying soils up through the slabs. We recommend that the floor covering installer test the moisture vapor flux rate prior to attempting applications of the flooring. "Breathable" floor coverings should be considered if the vapor flux rates are high. A slip-sheet or equivalent should be utilized above the concrete slab if crack-sensitive floor coverings (such as ceramic tiles, etc.) are to be placed directly on the concrete slab.
Additional guidance is provided in ACI Publications 302.1R-04 Guide for Concrete Floor and Slab Construction and 302.2R-06 Guide for Concrete Slabs that Receive Moisture-Sensitive Floor Materials.
6.2.6 Foundation Setback
We recommend a minimum horizontal setback distance from retaining walls or slopes for all structural foundations, footings, and other settlementsensitive structures as indicated on the Table 4 below. The minimum recommended setback distance from the most proximal foundation of retaining wall is equal to the height of the retaining wall. This distance is measured from the outside bottom edge of the structural footing, horizontally to the slope or retaining wall rear face, and is based on the slope or wall height. However, the foundation setback distance may be revised by the geotechnical consultant on a case-by-case basis if the geotechnical conditions are different than anticipated.
Table 4 – Minimum Foundation Setback
Slope/Wall Height Minimum Recommended Foundation
Setback
Less than 5 feet 5 feet
5 to 15 feet 7 feet
Greater than 20 feet H/2, where H is slope height; not to exceed 50 feet
Please note that the soils within the structural setback area possess poor lateral stability, and improvements (such as retaining walls, sidewalks, fences, pavements, etc.) constructed within this setback area may be subject to lateral movement and/or differential settlement. Potential distress to such Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
29 improvements may be mitigated by providing a deepened footing or a grade beam foundation system to support the improvement.
In addition, open or backfilled utility trenches that parallel or nearly parallel structure footings should not encroach within an imaginary 1:1 (horizontal to vertical) downward sloping line starting from the bottom edge of the footing and should also not be located closer than 18 inches from the face of the footing. Deepened footings should meet the setbacks as described above.
Also, over-excavation should be accomplished such that deepening of footings to accomplish the setback will not introduce a cut/fill transition bearing condition.
Where pipes cross under footings, the footings should be specially designed.
Pipe sleeves should be provided where pipes cross through footings or footing walls and sleeve clearances should provide for possible footing settlement, but not less than 1 inch around the pipe.
6.2.7 Floor Slabs
Slabs-on-grade should be at least 5 inches thick and be reinforced with No. 4 rebars 18 inches on center each way (minimum) placed at mid-height in the slab. We recommend control joints be provided across the slab at appropriate intervals as designed by the project architect.
For slab areas where vapor control is appropriate, a minimum 15-mil vapor barrier should be provided between the underslab and gravel capillary break. The vapor barrier should have a permeance of less than 0.01 perms across the entire slab area in the final constructed condition. Measures to protect the barrier should be implemented throughout the installation and slab construction process to prevent damage (ASTM E1643). Vapor barrier materials should conform to ASTM E1745 Class A. The gravel capillary break should consist of a layer of uniform 3/8-inch to 1/2-inch gravel that is at least 4-inches thick. The mix design of the slab concrete should be proportioned to control bleeding, shrinkage and curling.
Moisture barriers can retard, but not eliminate moisture vapor movement from the underlying soils up through the slabs. Moisture barriers can also prolong the timeframe needed for slabs to fully cure. We recommend that Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
30 the floor covering/insulation installer test the moisture vapor flux rate prior to flooring installation. “Breathable” floor coverings should be considered if the vapor flux rates are high. Additional guidance is provided in ACI Publications 302.1R-15 Guide for Concrete Floor and Slab Construction and 302.2R-06 Guide for Concrete Slab that Receive Moisture-Sensitive Floor Materials.
The potential for slab cracking may be reduced by careful control of water/cement ratios. The contractor should take appropriate curing precautions during the pouring of concrete in hot weather to minimize cracking of the slabs. We recommend that a slipsheet (or equivalent) be utilized if grouted tile, marble tile, or other crack-sensitive floor covering is planned directly on concrete slabs. All slabs should be designed in accordance with structural considerations. If heavy vehicle or equipment loading is proposed for the slabs, greater thickness and increased reinforcing may be required. The additional measures should be designed by the structural engineer using a modulus of subgrade reaction of 150 pounds per cubic inch. Additional moisture/waterproofing measures that may be needed to accomplish desired serviceability of the building finishes and should be designed by the project architect.
6.3 Temporary Excavations
Sloping excavations may be utilized when adequate space allows. Based on the results of our evaluation, we provide the following recommendations for sloped excavations in alluvium without seepage conditions.
Table 5 - Maximum Slope Ratios
Excavation Depth (feet)
Maximum Slope Ratio
In Alluvium
0 to 5 1:1 (Horizontal to Vertical)
5 to 20 1.5:1 (Horizontal to Vertical)
The above values are based on the assumption that no surcharge loading or equipment is present within 10 feet of the top of slope. Care should be taken during design of excavations adjacent to the existing structures so that foundation support is preserved. A “competent person” should observe the slope on a daily Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
31 basis for signs of instability. All excavations should comply with current OSHA requirements.
6.4 Lateral Earth Pressures and Retaining Wall Design
Retaining walls should be designed for the lateral soil pressures exerted on them, the magnitude of which depends primarily on the type of soil used as backfill and the amount of deformation the wall can yield under the lateral load. If a retaining wall can yield enough to mobilize the full shear strength of the soil, it can be designed for the ‘active’ pressure condition. Walls that are under restrained conditions and cannot yield under the applied load (e.g., basement walls) should be designed for the ‘at-rest’ pressure condition. If a wall tends to move towards the soils, the resulting resistance developed by the soil is the ‘passive’ resistance.
For design purposes, the following lateral earth pressure values for level or sloping backfill are recommended for walls backfilled with onsite soils of very low to low (EI<50) expansion potential or undisturbed in-place materials.
Table 6 - Static Equivalent Fluid Weight (pcf)
Conditions Level 2:1 Slope
Active 35 65
At-Rest 55 80
Passive 300 (Maximum of 3 ksf) 150 (sloping down)
Walls up to 10 feet in height should be designed for the applicable equivalent fluid unit weight values provided above. If conditions other than those covered herein are anticipated, the equivalent fluid unit weight values should be provided on an individual case-by-case basis by the geotechnical engineer. A surcharge load for a restrained or unrestrained wall resulting from automobile traffic may be assumed to be equivalent to a uniform lateral pressure of 75 psf which is in addition to the equivalent fluid pressure given above. For other uniform surcharge loads, a uniform pressure equal to 0.35q should be applied to the wall. The wall pressures assume walls are backfilled with free draining materials and water is not allowed to accumulate behind walls. A typical drainage design is contained in Appendix E.
Wall backfill should be compacted by mechanical methods to at least 90 percent relative compaction (based on ASTM D 1557). If foundations are planned over the Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
32 wall backfill, the wall backfill should be compacted to 95 percent. Wall footings should be designed in accordance with the foundation design recommendations and reinforced in accordance with structural considerations. For all retaining walls, we recommend a minimum horizontal distance from the outside base of the footing to daylight as outlined in Section 6.2.3.
Lateral soil resistance developed against lateral structural movement can be obtained from the passive pressure value provided above. Further, for sliding resistance, the friction coefficient of 0.35 may be used at the concrete and soil interface. These values may be increased by one-third when considering loads of short duration including wind or seismic loads. The total resistance may be taken as the sum of the frictional and passive resistance provided that the passive portion does not exceed two-thirds of the total resistance. The passive resistance and frictional coefficients are allowable values with a factor of safety of 1.5. The passive value for level ground assumes level conditions extend horizontally at least eight times the height of the surface imposing the horizontal loading.
To account for potential redistribution of forces during a seismic event, retaining walls providing lateral support where exterior grades on opposites sides differ by more than 6 feet fall under the requirements of 2022 CBC Section 1803.5.12 and/or ASCE 7-16 Section 15.6.1 and should also be analyzed for seismic loading.
For that analysis, an additional uniform lateral seismic force of 8H should be considered for the design of the retaining walls with level backfill, where H is the height of the wall. This value does not need to be increased for restrained walls.
6.5 Geochemical Considerations
Concrete in direct contact with soil or water that contains a high concentration of soluble sulfates can be subject to chemical deterioration commonly known as “sulfate attack.” Soluble sulfate results (Appendix C) indicated a negligible soluble sulfate content. We recommend that concrete in contact with earth materials be designed in accordance with Section 4 of ACI 318-19 (ACI, 2019). In addition, the electrical resistivity characteristics of the tested soil sample indicate a low corrosive site environment to ferrous materials in contact with earth materials. A corrosion consultant may be contacted for further recommendations.
6.6 Concrete Flatwork
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
33 Concrete sidewalks and other flatwork (including construction joints) should be designed by the project civil engineer and should have a minimum thickness of 4 inches. For all concrete flatwork, the upper 12 inches of subgrade soils should be moisture conditioned to at least 2 percent above optimum moisture content and compacted to at least 90 percent relative compaction based on ASTM Test Method D1557 prior to the concrete placement.
6.7 Preliminary Pavement Design
The pavement section design below is based on an assumed Traffic Index (TI), our visual classification of the subject site soils, and our limited laboratory testing (we have estimated an R-value of 20). The TI values were chosen based on our experience with similar projects. Actual pavement recommendations should be based on R-value tests performed on bulk samples of the soils that are exposed at the finished subgrade elevations across the site at the completion of the mass grading operations. Flexible pavement sections have been evaluated in general accordance with the Caltrans method for flexible pavement design. The recommended flexible pavement section for this condition is given in Table 7 below:
Table 7 - Preliminary Pavement Sections
Assumed Traffic Index (TI) Asphalt Concrete
(inches)
Aggregate Base
(inches)
4.5 3.0 5.0
5.0 3.0 6.5
6.0 4.0 8.5
Flexible pavements should be constructed in accordance with current Caltrans Standard Specifications. Aggregate base should comply with the Caltrans Standard Specifications of Section 26. Aggregate base should be compacted to a minimum of 95 percent relative compaction based on ASTM Method D 1557.
For areas subject to regular truck loading (i.e., trash truck apron), we recommend a full depth of Portland Cement Concrete (P.C.C.) section of 7 inches with appropriate steel reinforcement and crack-control joints as designed by the project structural Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
34 engineer. We recommend that sections be as nearly square as possible. A 3,500- psi mix that produces a 550-psi modulus of rupture should be utilized.
All pavement section materials conform to and be placed in accordance with the latest revision of the California Department of Transportation Standard Specifications (Caltrans) and American Concrete Institute (ACI) codes. The upper 12 inches of subgrade soil and all aggregate base should be compacted to a relative compaction of at least 95 percent (based on ASTM Test Method D1557).
If pavement areas are adjacent to heavily watered landscape areas, we recommend some measure of moisture control be taken to prevent the subgrade soils from becoming saturated. It is recommended that the concrete curing separating the landscaping area from the pavement extend below the aggregate base to help seal the ends of the sections where heavy landscape watering may have access to the aggregate base. Concrete swales should be designed in roadway or parking areas subject to concentrated surface runoff.
6.8 Control of Ground Water and Surface Waters
Regarding Low Impact Development (LID) measures, we are of the opinion that infiltration basins, and other onsite storm water retention and infiltration systems can potentially create adverse perched ground water conditions when not installed using proper design recommendations (such as the use of liners) and infiltration design parameters. Based on our evaluation, the site is considered a “partial infiltration” site.
Surface drainage should be controlled at all times and carefully taken into consideration during precise grading, landscaping, and construction of site improvements. Positive drainage (e.g., roof gutters, downspouts, area drains, etc.) should be provided to direct surface water away from structures and improvements and towards the street or suitable drainage devices. Ponding of water adjacent to structures or pavements should be avoided. Roof gutters, downspouts, and area drains should be aligned so as to transport surface water to a minimum distance of 5 feet away from structures. The performance of structural foundations is dependent upon maintaining adequate surface drainage away from structures.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
35 Water should be transported off the site in approved drainage devices or unobstructed swales. We recommend a minimum flow gradient for unpaved drainage within 5 feet of structures of 2 percent sloping away.
The impact of heavy irrigation or inadequate runoff gradient can create perched water conditions, resulting in seepage or shallow ground water conditions where previously none existed. Maintaining adequate surface drainage and controlled irrigation will significantly reduce the potential for nuisance-type moisture problems.
To reduce differential earth movements such as heaving and shrinkage due to the change in moisture content of foundation soils, which may cause distress to a structure and improvements, moisture content of the soils surrounding the structure should be kept as relatively constant as possible. Below grade planters should not be situated adjacent to structures or pavements unless provisions for drainage such as catch basins and drains are made.
All area drain inlets should be maintained and kept clear of debris in order to function properly. In addition, landscaping should not cause any obstruction to site drainage.
Rerouting of drainage patterns and/or installation of area drains should be performed, if necessary, by a qualified civil engineer or a landscape architect.
6.9 Construction Observation
The recommendations provided in this report are based on preliminary design information and subsurface conditions disclosed by widely spaced excavations.
The interpolated subsurface conditions should be checked by Leighton in the field during construction. Construction observation of all onsite excavations and field density testing of all compacted fill should be performed by a representative of this office. We recommend that all excavations be mapped by the geotechnical consultant during grading to determine if any potentially adverse geologic conditions exist at the site.
6.10 Plan Review
Final project grading and foundation plans should be reviewed by Leighton as part of the design development process to ensure that recommendations in this report are incorporated in project plans.
Preliminary Geotechnical Investigation Project No. 11832.002 Santee 3 Residential Development February 5, 2024
36 7.0 LIMITATIONS
The conclusions and recommendations presented in this report are based in part upon data that were obtained from a limited number of observations, site visits, excavations, samples, and tests. Such information is by necessity incomplete. The nature of many sites is such that differing geotechnical or geological conditions can occur within small distances and under varying climatic conditions. Changes in subsurface conditions can and do occur over time. Therefore, the findings, conclusions, and recommendations presented in this report can be relied upon only if Leighton has the opportunity to observe the subsurface conditions during grading and construction of the project, in order to confirm that our preliminary findings are representative for the site.
FIGURES
Scale:1 " = 2,000 '
Project: 11832.002 Eng/Geol: NJT/RNB
Map Saved as V:\Drafting\11832\002\Maps\11832-002_F01_SLM_2022-04-20.mxd on 4/20/2023 11:23:16 AM Author: (mmurphy)
Date: April 2023
SITE LOCATION MAP
Approximate
Site Boundary
³ 0 2,000 4,000
Feet
FIGURE 1
Reference: © 2023 Microsoft Corporation ©
2023 Maxar ©CNES (2023) Distribution Airbus
Santee 3 Multi-Family Development
Santee, California
#0
#*
#*
#*
#0
#0 #0
#* #*
#* #*
&( #0 #0
&( &(
&<
&<
C
otto
n
w
o
o
d
Av
e
C
h
u
b
b
L
n
P
ark
C
e
nter Dr
Qya
Qya
Qya
Qya
CPT-8
CPT-6
CPT-1
CPT-7
CPT-13
CPT-11
CPT-9
CPT-5
CPT-2
CPT-3
CPT-4
CPT-10 P-1
CPT-12
P-2
P-3
5-1
4-2
334
350
344 332
342
346
330
340 342
336
346
330
330
330
332
346
330
348
350
330
330
330
332
348
344
346
342
344
332
332
342
350
352
342
346
352
330
348
348
350
330
332
330
344
330
334
330
332
330
330
336
332
348
330
332
330
344
348
346
342
352
330
330
350
342
338
334
348
332
348
352
332
330
342
342
332
330
330
344
350
338
344
336
346
352
330
330
348
330
332
330
332
338
344
348
330
352
346
350
352
330
344
330
344
342
342
330
330
348
338
352
350
344
330
332
332
330
330
330
342
332
330
330
344
330
330
330
334
330
338
350
330
342
354
330
350
330
348
344
348
346
338
338
336
344
350
340
344
352
346
342
340
350
342
342
346
338
340
334
344
336
332
342
344
348
346
330
³ 0 150 300
Feet
Map Saved as V:\Drafting\11832\002\Maps\11832-002_F02_GM_2022-04-20.mxd on 5/5/2023 9:19:10 AM
GEOTECHNICAL MAP
Santee 3 Multi-Family Development
Santee, California
Scale:1 " = 150 '
Project: 11832.002 Eng/Geol: NJT/TCS
Author: (mmurphy)
Date: May 2023
FIGURE 2
Base Map: Google Earth, 2023.
Legend
#0 Approximate Location of Cone Penetrometer (CPT)
(Leighton, This Study)
&( Approximate Location of Percolation Test
(Leighton, This Study)
#* Approximate Location of Cone Penetrometer (CPT)
(Leighton, 2017)
&< Approximate Location of Boring
(Law Crandall, 1999)
Approximate Site Boundary
Geologic Units
Quaternary-aged Young Allulvium
CPT-13
P-3
CPT-7
4-2
Qya
Qoa
Qoa
Qoa
Qya
Qya
Qya
Qya
Tf
Kgt
Qoa
Kgt
FIGURE 3
Scale:
Base Map: Geologic Map of the El Cajon 7.5' Quadrangle
San Diego County, California by Siang S. Tan, 2002.
1 " = 1,000 '
Project: 11832.002 Eng/Geol: NJT/TCS
Map Saved as V:\Drafting\11832\002\Maps\11832-002_F03_GM_2022-04-20.mxd on 4/20/2023 11:51:24 AM Author: (mmurphy)
Date: April 2023 GEOLOGIC MAP
Santee 3 Multi-Family Development
Santee, California
Approximate
Site Location
Qya
Qoa
Holocence alluvial deposits unconsolidated to poorly consolidated silt, clay, sand and gravel. Includes sediments along small, active drainage channels.
Late Pleistocene alluvial deposits; moderately consolidated, poorly-sorted flood plain deposits consisting of gravelly, sandy silt and clay.
Tf Friars Formation (middle Eocene); poorly indurated, non-marine claystone and sandstone, with lenses of cobble conglomerate. The formation contains many landslides.
Kgt Tonalite (Cretaceous); includes some granodiorite and quartz diorite; medium-grained; generally dark colored and severely weathered.
Legend
³ 0 1,000 2,000
Feet
!"_$
!"^$ !"a$
?¸
?nE
?±
%&s(
%&s(
?¸
Approximate
Site Location
Palos
Verdes
Newport-Inglewood
Thirty Mile Bank Fault
Rose Canyon Fault
Elsinore
Fault
San Diego Trough
Fault Zone
Coronado Bank Fault Zone
Earthquake Valley Fault
San Jacinto (Anza)
San Andreas
(North Branch Mill Creek)
Coronado
Bank fault zone
San Jacinto (Coyote Creek)
Newport-Inglewood
Whittier
Elsinore fault zone, Temecula section
(Murrieta Creek fault)
Elsinore (Glen Ivy)
Map Saved as V:\Drafting\11832\002\Maps\11832-002_F04_RFM_2022-04-20.mxd on 4/20/2023 12:07:27 PM ³ 0 15 30
Miles
Scale:
Faults: Bryant, Bryant CGS 2010
1 " = 15 miles
Project: 11832.002 Eng/Geol: NJT/TCS
Author: Leighton Geomatics (mmurphy)
Date: April 2023
Legend
Faults (by age)
Historic (<200 years)
Holocene (<10K years)
Late Quaternary (<700K years)
Quaternary (<1.6M years)
pre-Quaternary (>1.6M years)
REGIONAL FAULT MAP
Santee 3 Multi-Family Development
Santee, California
FIGURE 4
Scale:1 " = 2,000 '
Project: 11832.002 Eng/Geol: NJT/RNB
Map Saved as V:\Drafting\11832\002\Maps\11832-002_F05_FHZM_2023-05-05.mxd on 5/5/2023 9:12:21 AM Author: (mmurphy)
Date: May 2023
FLOOD HAZARD ZONE MAP
Approximate
Site Location
³ 0 2,000 4,000
Feet
FIGURE 5
Base Map: © 2023 Microsoft Corporation ©
2023 Maxar ©CNES (2023) Distribution Airbus
Santee 3 Multi-Family Development
Santee, California
Legend
500 Year Flood Plain
100 Year Flood Plain
Reference: FEMA, DWR
APPENDIX A
References
Preliminary Geotechnical Investigation
Santee 3 Residential Development
Project No. 11832.002
May 19, 2023
A-1
APPENDIX A
REFERENCES
ACI, 2019, Building Code Requirements for Structural Concrete (ACI 318-19) and Commentary, American Concrete Institute.
Associated Society of Civil Engineers (ASCE), 2016, ASCE Standard 7-16, Minimum Design Loads for Buildings and Other Structures, 2016.
California Emergency Management Agency (CalEMA), California Geological Survey, and University of Southern California, 2009, Tsunami Inundation Maps for Emergency Planning, Scale 1:24,000, June 1.
California Geologic Survey (CGS), 2007, Fault Rupture Hazard Zones in California, Special Publication No. 42, Revised 2007 (Interim Version).
California Building Standards Commission (CBSC), 2013, California Building Code, Volumes 1 and 2.
California Building Code (CBC), 2022, California Building Code.
County of San Diego, 2020, BMP Design Manual For Permanent Site Design, Storm Water Treatment and Hydromodification Management, dated September 15, 2020.
FEMA, 2012, Flood Insurance Maps, Panel 1618 of 2375, dated May 16.
Jennings, C.W., 2010, Fault Activity Map of California and Adjacent Areas: California Division of Mines and Geology, California Geologic Map Series, Map No. 6 Law Crandall, 1999, Report of Preliminary Geotechnical Investigation for Rough Grading, Proposed Santee Town Center Edgemoor Property, Santee, California, dated May 7, 1999.
Kennedy, M.P., and Tan, S.S., 2008, Geologic Map of the El Cajon Quadrangle, California, California Geologic Survey, 1:100,000 scale.
Treiman, J.A., 2002, Silver Strand Fault, Coronado Fault, Spanish Bight Fault, San Diego Fault, and Downtown Graben, Southern Rose Canyon Fault Zone, San Diego, California, Fault Evaluation Report FER-245, California Division of Mines and Geology, dated June 17, Supplement dated April 22, 2003.
Preliminary Geotechnical Investigation
Santee 3 Residential Development
Project No. 11832.002
May 19, 2023
A-2
APPENDIX A
REFERENCES (Continued)
________, 1993, The Rose Canyon Fault Zone, Southern California, California Division of Mines and Geology, Open File Report 93-02.
United States Department of Agriculture, 1953, Aerial Photographs, Flight AXN-3M, Numbers 98 and 99 scale approximately 1:24,000, dated March 31, 1953.
APPENDIX B
Field Exploration Logs
SUMMARY
OF
CONE PENETRATION TEST DATA
Prepared by:
KEHOE TESTING & ENGINEERING
5415 Industrial Drive
Huntington Beach, CA 92649-1518
Office (714) 901-7270 / Fax (714) 901-7289
www.kehoetesting.com
Project:
City Ventures – Santee 3 Geoinv
Cottonwood Avenue & Claudia Avenue
Santee, CA
April 24, 2023
Prepared for:
Mr. Nick Tracy
Leighton & Associates
3934 Murphy Canyon Road, B205
San Diego, CA 92123-4425
Office (800) 447-2626 / Fax (858) 292-0771
TABLE OF CONTENTS
1. INTRODUCTION
2. SUMMARY OF FIELD WORK
3. FIELD EQUIPMENT & PROCEDURES
4. CONE PENETRATION TEST DATA & INTERPRETATION
APPENDIX
• CPT Plots
• CPT Classification/Soil Behavior Chart
• CPT Data Files (sent via email)
SUMMARY
OF
CONE PENETRATION TEST DATA
1. INTRODUCTION
This report presents the results of a Cone Penetration Test (CPT) program carried out for the City Ventures – Santee 3 Geoinv project located at Cottonwood Avenue & Claudia Avenue in Santee, California. The work was performed by Kehoe Testing & Engineering (KTE) on April 24, 2023. The scope of work was performed as directed by Leighton & Associates personnel.
2. SUMMARY OF FIELD WORK
The fieldwork consisted of performing CPT soundings at six locations to determine the soil lithology. A summary is provided in TABLE 2.1.
LOCATION
DEPTH OF
CPT (ft) COMMENTS/NOTES:
CPT-8 46 Refusal
CPT-9 47 Refusal
CPT-10 38 Refusal
CPT-11 36 Refusal
CPT-12 38 Refusal
CPT-13 50
TABLE 2.1 - Summary of CPT Soundings
3. FIELD EQUIPMENT & PROCEDURES
The CPT soundings were carried out by KTE using an integrated electronic cone system manufactured by Vertek. The CPT soundings were performed in accordance with ASTM standards (D5778). The cone penetrometers were pushed using a 30-ton CPT rig. The cone used during the program was a 15 cm^2 cone with a cone net area ratio of 0.83. The following parameters were recorded at approximately 2.5 cm depth intervals:
• Cone Resistance (qc) • Inclination
• Sleeve Friction (fs) • Penetration Speed
• Dynamic Pore Pressure (u)
The above parameters were recorded and viewed in real time using a laptop computer. Data is stored at the KTE office for up to 2 years for future analysis and reference. A complete set of baseline readings was taken prior to each sounding to determine temperature shifts and any zero load offsets. Monitoring base line readings ensures that the cone electronics are operating properly.
4. CONE PENETRATION TEST DATA & INTERPRETATION
The Cone Penetration Test data is presented in graphical form in the attached Appendix. These plots were generated using the CPeT-IT program. Penetration depths are referenced to ground surface. The soil behavior type on the CPT plots is derived from the attached CPT SBT plot (Robertson, “Interpretation of Cone Penetration Test…”, 2009) and presents major soil lithologic changes. The stratigraphic interpretation is based on relationships between cone resistance (qc), sleeve friction (fs), and penetration pore pressure (u). The friction ratio (Rf), which is sleeve friction divided by cone resistance, is a calculated parameter that is used along with cone resistance to infer soil behavior type. Generally, cohesive soils (clays) have high friction ratios, low cone resistance and generate excess pore water pressures. Cohesionless soils (sands) have lower friction ratios, high cone bearing and generate little (or negative) excess pore water pressures.
The CPT data files have also been provided. These files can be imported in CPeT-IT (software by GeoLogismiki) and other programs to calculate various geotechnical parameters.
It should be noted that it is not always possible to clearly identify a soil type based on qc, fs and u. In these situations, experience, judgement and an assessment of the pore pressure data should be used to infer the soil behavior type.
If you have any questions regarding this information, please do not hesitate to call our office at (714) 901-7270.
Sincerely,
KEHOE TESTING & ENGINEERING
Steven P. Kehoe
President
04/27/23-aga-5234
APPENDIX
Project: Leighton & Associates / City Ventures - Santee 3 Geoinv Kehoe Testing and Engineering
714-901-7270
[email protected]
www.kehoetesting.com
Cottonwood Ave & Claudia Ave, Santee, CA Total depth: 46.20 ft, Date: 4/24/2023 CPT-8
Location:
Cone resistance
HAND AUGER
Tip resistance (tsf)
0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Cone resistance Sleeve friction
HAND AUGER
Friction (tsf)
0 2 4 6 8 1 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Sleeve friction Pore pressure u
HAND AUGER
Pressure (psi)
-2 0 0 2 0 4 0 6 0 8 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Pore pressure u Friction ratio
HAND AUGER
Rf (%)
0 1 2 3 4 5 6 7 8
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Friction ratio Soil Behaviour Type
HAND AUGER
SBT (Robertson, 2010)
0 2 4 6 8 1 0 1 2 1 4 1 6 1 8
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Soil Behaviour Type
Silty sand & sandy silt
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Sand & silty sand
Silty sand & sandy silt
Sand & silty sand
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Silty sand & sandy silt
Clay
Clay & silty clay
Sand & silty sand
Sand & silty sand
Sand & silty sand
Sand & silty sand
Sand
CPeT-IT v.2.3.1.9 - CPTU data presentation & interpretation software - Report created on: 4/25/2023, 12:47:24 PM 1 Project file: C:\CPT Project Data\Leighton-Santee4-23\CPT Report\CPeT.cpt Project: Leighton & Associates / City Ventures - Santee 3 Geoinv Kehoe Testing and Engineering
714-901-7270
[email protected]
www.kehoetesting.com
Cottonwood Ave & Claudia Ave, Santee, CA Total depth: 47.51 ft, Date: 4/24/2023 CPT-9
Location:
Cone resistance
HAND AUGER
Tip resistance (tsf)
0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Cone resistance Sleeve friction
HAND AUGER
Friction (tsf)
0 2 4 6 8 1 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Sleeve friction Pore pressure u
HAND AUGER
Pressure (psi)
-2 0 0 2 0 4 0 6 0 8 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Pore pressure u Friction ratio
HAND AUGER
Rf (%)
0 1 2 3 4 5 6 7 8
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Friction ratio Soil Behaviour Type
HAND AUGER
SBT (Robertson, 2010)
0 2 4 6 8 1 0 1 2 1 4 1 6 1 8
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Soil Behaviour Type
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Clay & silty clay
Clay
Silty sand & sandy silt
Sand & silty sand
Sand & silty sand
Clay & silty clay
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Silty sand & sandy silt
Sand & silty sand
Sand & silty sand
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Silty sand & sandy silt
Clay & silty clay
Sand & silty sand
Silty sand & sandy silt
Silty sand & sandy silt
Silty sand & sandy silt
Clay & silty clay
Silty sand & sandy silt
Very dense/stiff soil
Sand & silty sand
CPeT-IT v.2.3.1.9 - CPTU data presentation & interpretation software - Report created on: 4/25/2023, 12:47:24 PM 2 Project file: C:\CPT Project Data\Leighton-Santee4-23\CPT Report\CPeT.cpt Project: Leighton & Associates / City Ventures - Santee 3 Geoinv Kehoe Testing and Engineering
714-901-7270
[email protected]
www.kehoetesting.com
Cottonwood Ave & Claudia Ave, Santee, CA Total depth: 38.06 ft, Date: 4/24/2023 CPT-10
Location:
Cone resistance
HAND AUGER
Tip resistance (tsf)
0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Cone resistance Sleeve friction
HAND AUGER
Friction (tsf)
0 2 4 6 8 1 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Sleeve friction Pore pressure u
HAND AUGER
Pressure (psi)
-2 0 0 2 0 4 0 6 0 8 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Pore pressure u Friction ratio
HAND AUGER
Rf (%)
0 1 2 3 4 5 6 7 8
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Friction ratio Soil Behaviour Type
HAND AUGER
SBT (Robertson, 2010)
0 2 4 6 8 1 0 1 2 1 4 1 6 1 8
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Soil Behaviour Type
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Sand & silty sand
Silty sand & sandy silt
Sand & silty sand
Sand & silty sand
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Sand & silty sand
Silty sand & sandy silt
Sand & silty sand
Sand
Sand & silty sand
CPeT-IT v.2.3.1.9 - CPTU data presentation & interpretation software - Report created on: 4/25/2023, 12:47:25 PM 3 Project file: C:\CPT Project Data\Leighton-Santee4-23\CPT Report\CPeT.cpt Project: Leighton & Associates / City Ventures - Santee 3 Geoinv Kehoe Testing and Engineering
714-901-7270
[email protected]
www.kehoetesting.com
Cottonwood Ave & Claudia Ave, Santee, CA Total depth: 36.49 ft, Date: 4/24/2023 CPT-11
Location:
Cone resistance
HAND AUGER
Tip resistance (tsf)
0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Cone resistance Sleeve friction
HAND AUGER
Friction (tsf)
0 2 4 6 8 1 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Sleeve friction Pore pressure u
HAND AUGER
Pressure (psi)
-2 0 0 2 0 4 0 6 0 8 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Pore pressure u Friction ratio
HAND AUGER
Rf (%)
0 1 2 3 4 5 6 7 8
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Friction ratio Soil Behaviour Type
HAND AUGER
SBT (Robertson, 2010)
0 2 4 6 8 1 0 1 2 1 4 1 6 1 8
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Soil Behaviour Type
Silty sand & sandy silt
Sand & silty sand
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Silty sand & sandy silt
Silty sand & sandy silt
Sand & silty sand
Silty sand & sandy silt
Clay & silty clay
Clay
Sand & silty sand
Sand & silty sand
Sand & silty sand
Sand & silty sand
Sand & silty sand
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Sand & silty sand
CPeT-IT v.2.3.1.9 - CPTU data presentation & interpretation software - Report created on: 4/25/2023, 12:47:25 PM 4 Project file: C:\CPT Project Data\Leighton-Santee4-23\CPT Report\CPeT.cpt Project: Leighton & Associates / City Ventures - Santee 3 Geoinv Kehoe Testing and Engineering
714-901-7270
[email protected]
www.kehoetesting.com
Cottonwood Ave & Claudia Ave, Santee, CA Total depth: 38.06 ft, Date: 4/24/2023 CPT-12
Location:
Cone resistance
HAND AUGER
Tip resistance (tsf)
0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Cone resistance Sleeve friction
HAND AUGER
Friction (tsf)
0 2 4 6 8 1 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Sleeve friction Pore pressure u
HAND AUGER
Pressure (psi)
-2 0 0 2 0 4 0 6 0 8 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Pore pressure u Friction ratio
HAND AUGER
Rf (%)
0 1 2 3 4 5 6 7 8
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Friction ratio Soil Behaviour Type
HAND AUGER
SBT (Robertson, 2010)
0 2 4 6 8 1 0 1 2 1 4 1 6 1 8
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Soil Behaviour Type
Silty sand & sandy silt
Sand & silty sand
Sand & silty sand
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Sand & silty sand
Silty sand & sandy silt
Sand & silty sand
Sand & silty sand
Silty sand & sandy silt
Sand & silty sand
Silty sand & sandy silt
Clay & silty clay
Silty sand & sandy silt
Sand & silty sand
Sand & silty sand
CPeT-IT v.2.3.1.9 - CPTU data presentation & interpretation software - Report created on: 4/25/2023, 12:47:26 PM 5 Project file: C:\CPT Project Data\Leighton-Santee4-23\CPT Report\CPeT.cpt Project: Leighton & Associates / City Ventures - Santee 3 Geoinv Kehoe Testing and Engineering
714-901-7270
[email protected]
www.kehoetesting.com
Cottonwood Ave & Claudia Ave, Santee, CA Total depth: 50.22 ft, Date: 4/24/2023 CPT-13
Location:
Cone resistance
HAND AUGER
Tip resistance (tsf)
0 1 0 0 2 0 0 3 0 0 4 0 0 5 0 0 6 0 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Cone resistance Sleeve friction
HAND AUGER
Friction (tsf)
0 2 4 6 8 1 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Sleeve friction Pore pressure u
HAND AUGER
Pressure (psi)
-2 0 0 2 0 4 0 6 0 8 0
Depth (ft)
5 0
4 8
4 6
4 4
4 2
4 0
3 8
3 6
3 4
3 2
3 0
2 8
2 6
2 4
2 2
2 0
1 8
1 6
1 4
1 2
1 0
8 6
4 2
0 Pore pressure u Friction ratio