JULY 05, 2023 (Revised 9.26.2023)
1150-1170 KIFER Sunnyvale, California
1 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
TABLE OF CONTENTS
2 LU SUBMITTAL 05 JULY 05, 2023
INTRO
ZONING & DATA
SITE CONTEXT
RENDERINGS
ZONING DIAGRAMS
CIVIL
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 24
25 26
27 28
29 30
31 32
33 34
35 36
37 38
39 40
41 42
43 44
45 46
47 48
49 50
51 52
53 54
55 56
57 58
59 60
61 62
63 64
65 66
67 68
69 70
71 72
73 74
75 76
77 78
79 80
81 82
83 84
85 86
87 88
89 90
91 92
93 94
95 96
97 98
99 100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
LANDSCAPE ARCHITECTURE
EXHIBITS
Cover
Table of Contents
Project Summary
Overall Site Plan
Site Photos - Looking out
Site Photos - Looking in
Context Map
Rendering - Northeast Corner View
Rendering - Main Entry Vignette
Rendering - North Elevation View
Rendering - Townhomes Views
Rendering - North Path View
Rendering - 2nd Entry Vignette
Rendering - West Vignette
Rendering - South Elevation View
Rendering - Southeast View
Rendering - Shared Use Path Vignette - West
Rendering - Shared Use Path Vignette - East
Land Coverage
Building Height
Setback - San Zeno Way
Setback - Shared Use Path
Active Use
Open Space Area
Not used - sheet omitted
Landscape Area
Site Circulation
Horizontal Building Articulation
Horizontal Building Articulation
Vertical Modules Diagrams
Elevation Diagrams
Roof Height Variation Diagrams
Building Context
Window openings - Savoy
TM1.0 Tentative Parcel Map
C1.0 Existing Conditions and Tree Removal Plan
C2.0 Preliminary Site Plan
C2.1 Overall Preliminary Site Plan
C3.0 Preliminary Grading and Drainage Plan
C4.0 Preliminary Utility Plan
C5.0 Preliminary Stormwater Management Plan
C6.0 Fire and Vehicular Access Exhibit
C7.0 Future Right-of-Way
Overall Site Plan - Key Map Existing Conditions
Landscape Area - Lot 2 Office Building
Landscape Area - Lot 1 Residential Building
Report, Notes and Plan - Arborist Report
Tree Protection Details - Arborist Report
Tree Protection & Removal Plan 1 of 2
Tree Protection & Removal Plan 2 of 2
Materials Plan 1 of 2
Materials Plan 2 of 2
Materials Plan Level 4
Materials Plan Level 8
Site Furnishing
Site Surfaces
Site Plan 1 of 2 - Irrigation
Site Plan 2 of 2 - Irrigation
Site Plan - Irrigation Level 4
Site Plan - Irrigation Level 8
General Site Notes - Irrigation
Notes & Details - Irrigation
Notes & Details - Irrigation
Notes & Details - Irrigation
Notes & Details - Irrigation
Notes & Details - Irrigation
Water Calculations - Irrigation
Water Effecient Checklist - Lot 2 Office
Water Effecient Checklist - Lot 1 Office
Hydrozone Plan 1 of 2 - Landscape Site Plan
Hydrozone Plan 2 of 2 - Landscape Site Plan
Hydrozone Plan - Landscape Plan Level 4
Hydrozone Plan - Landscape Plan Level 8
Landscape Site Plan - Planting Plan 1 of 2 - Site Plan
Ground Level Office Proposed Planting Sheet 1 of 2
Ground Level Office Proposed Planting Sheet 2 of 2
Landscape Site Plan - Planting Plan 2 of 2 - Site Plan
Ground Level Site Proposed Planting Sheet 1 of 2
Ground Level Site Proposed Planting Sheet 2 of 2
Planting Plan - Landscape Plan Level 4
4th Level Proposed Planting
Planting Plan - Landscape Plan Level 8
8th Level Proposed Planting
Lighting Plan
Landscape Sections
Landscape Sections
Landscape Sections
Site Plan
Ground Story Plan
2nd Story Plan
3rd Story Plan
4th Story Plan
5th Story Plan
6th Story Plan
7th Story Plan
8th Story Plan
Roof Plan
Building Elevations
Building Elevations
Building Sections
Material Palette - North
Material Palette - South
Material Board
Unit Layout Examples
Overall Site Parking
Ground Story Parking
2nd Story Parking
3rd Story Parking
Metal Screen Greenwall 1 of 2
Metal Screen Grennwall 2 of 2
Architectural Lighting Plan
Lighting Site Plan
Site Photometrics
Garage Door Design
Bicycle Racks
Lockable Storage
In-Unit Storage Story Plans
In-Unit Storage Typical Floor Plans
Rooftop Visibility
Building Cornice
Guardrail Details
Base - Brick Texture
Control Joint Detail
Window Details - Thin Brick
Sunnyvale Gateway Sign - Lawrence Station
Trash Exibit - Trash Enclosure
Trash Exhibit - Site Plan
Trash Exhibit - Upper Stories
Trash Exhibit - Main Trash Collection Rooms
Trash Exhibit - Secondary Trash Collection Room
Trash Exhibit - Trash Staging Enclosure
Trash Exhibit - Trash Pickup Truck Maneuver
GPR Checklist
ROW Photometric Plan
Rooftop Sight Line - Lawrence Expy
Rooftop Sight Line - Sorona Ct
Rooftop Sight Line - Kifer Rd
Attachment 6
PROJECT SUMMARY
3 LU SUBMITTAL 05 JULY 05, 2023
1ST 2ND 3RD 4TH 5TH 6TH 7TH 8TH
0 0 1 6 5 6 6 6 30 13.3%
0 0 9 22 24 24 24 22 125 55.6%
4 0 5 9 10 12 12 10 62 27.6%
800000 0 0 8 3 . 6 %
12 0 15 37 39 42 42 38 225 100.0%
9,824 4,912 12,542 29,396 32,014 34,824 34,620 29,970
3,560 0 454 3,067 0 0 0 740
4,320 1,600 4,100 5,380 4,700 4,700 4,700 5,800
30,775 35,686 37,079 0 0 0 0 0
6,265 5,450 7,650 480 480 480 480 480
54,744 47,648 61,825 38,323 37,194 40,004 39,800 36,990
CIRCULATION (SF)
PARKING (SF)
21,765
1,359
91,833
67,6862 BEDROOM 1,092
7351 BEDROOM
356,528
10,868
RESIDENTIAL AMENITIES & FITNESS (SF)
188,102
7,821
35,300
103,540
TOTAL UNITS 188,102836
NET RENTABLE (SF)
UTILITY / MEP / BIKE PARKING (SF)
TOTAL GROSS (SF)
3 BED TOWNHOMES
STUDIOS
RATIO
UNITS BY FLOOR
COUNT
17,715591
CATEGORY
TOTAL (SF)
UNIT AVG (SF)UNIT TYPE
1150 - 1170 KIFER RD.
SUNNYVALE, CA 94086
KIFER RD
LAWRENCE EXPY
VICINITY MAP
SITE AREA
LSAP ZONING
LAND USE TYPE
SETBACKS
REQUIRED PROPOSED REFERENCE
ZONING HEIGHT MAX 100'-0" 88'-6" P. 21
LOT COVERAGE MAX 80% 69% P. 20
OPEN SPACE 50 SF / UNIT
(11,200 SF) 45,000 SF P. 25
LANDSCAPE AREA 20% BASE
(40% = 5 PTS.) 35,312 SF P. 27, 49
RESIDENTIAL UNITS 225 P. 93 - 100
CLUBHOUSE / AMENITY ROOM AREA 450 SF 2,188 SF P. 96 & P 100 * NO EXPANSION OF THE OFFICE USE IS OCCURING / PROPOSED. ONLY PROPOSING AN ADJUSTMENT TO THE PARCEL SIZE
ZONING INFO
87,156 SF (2 ACRES)
MXD-1
MULTI FAMILY RESIDENTIAL
FRONT - 15'
REAR - 10'
SECONDARY BIKE PATH - 22'
SIDE - 10'
1ST - 3RD STORY
4TH - 8TH STORY
CONSTRUCTION TYPE
TYPE 1A: 161,010 SF
TYPE IIIA: 195,516 SF
PROPOSED BUILDING INFO
APPLICABLE CODES
SUNNYVALE MUNICIPAL CODES (SMC)
2022 CALIFORNIA BUILDING CODES
SUNNYVALE AMENDMENTS TO THE CALIFORNIA FIRE CODE (SMC 16.52) 2022 CALIFORNIA FIRE CODE (CFC)
NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) CODES AND STANDARDS EXISTING 1150 LOT SIZE
EXISTING 1170 LOT SIZE
PROPOSED MODIFIED LOT SIZE
SITE SQFT
EXISTING 1150 OFFICE SF 46,849 sf
EXISTING 1170 OFFICE SF 57,649 sf
PROPOSED FAR NO CHANGE - 104,498 SF
OFFICE EXISTING PARKING 394 TOTAL EXISTING PARKING STALLS
OFFICE PARKING REQUIRED
EXISTING TO REMAIN
PROPOSED SHARED PARKING STALLS
TOTAL OFFICE PARKING 288 MIN / 418 MAXIMUM
OFFICE CAR SHARE REQUIREMENT 5% OF OFFICE PARKING
OFFICE BICYCLE PARKING REQUIRED EXISTING REFERENCE
CLASS I 14 15 P. 109 & P. 28
CLASS II 4 29 P. 109 & P. 28
STUDIO
1 BED
2 BED
3 BED
TOTAL
STATE DENSITY BONUS PARKING RATIO .5 SPACES PER UNIT
EV PARKING TYPE REQUIRED PROPOSED REFERENCE
65% LEVEL 1 EV READY SPACE (SHARED) 101 101 P. 110-112 35% LEVEL 2 ELECTRIC VEHICLE CHARGING STATIONS (SHARED) 55 55 P. 110-112 65% LEVEL 1 ELECTRIC VEHICLE READY CIRCUIT (RESIDENTIAL) 73 73 P. 110-112 35% LEVEL 2 ELECTRIC VEHICLE CHARGING STATIONS (RESIDENTIAL) 40 40 P. 110-112
BICYCLE PARKING REQUIRED PROPOSED REFERENCE
CLASS I 1 / 4 UNITS = 57 357 P. 111-112
CLASS II 1 / 15 UNITS = 15 22 P. 55
STORAGE REQUIRED PROPOSED REFERENCE
STUDIO 1 / UNIT: 200 CF 225 UNITS P. 120-122,
1 BED 1 / UNIT: 200 CF & P. 111-112
2 BED+ 1 / UNIT: 300 CF
1 / UNIT = 125
RESIDENTIAL AUTOMOBILE PARKING
1 / UNIT = 30
FAR: 41%
FAR: 61%
114,084 sf (2.62 ACRES)
139,608 SF (3.20 ACRES)
166,546 SF (3.82 ACRES)
PROPOSED
243 TO BE REMOVED
FAR
FAR: 41%
148 STALLS
156 STALLS
304 STALLS
16 STALLS
EV PARKING
225 UNITS = 113 STALLS
1.25 / UNIT = 78
1.7 / UNIT = 14
247
OFFICE SITE PARCEL
OFFICE AUTOMOBILE PARKING
OFFICE BUILDING SQFT / FAR
LOT SIZE
301 STALLS
* 3 - Waste Staging
142 STALLS
* 3 - Waste Staging
Attachment 6
OVERALL SITE PLAN
4 LU SUBMITTAL 05 JULY 05, 2023
EV
EV
EV
SL
AL
SAN ZENO WAY
KIFER RD.
LAWRENCE EXPRESSWAY
(E) ONE STORY OFFICE
BUILDING
(E) ONE STORY OFFICE
BUILDING
SOUTH PARCEL
2 ACRES
SITE PLAN 1/40 SCALE
MARCH 10, 2022 LU35
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1" = 40'-0"LU35
1 STE PLAN
EV
EV
EV
SL
AL
SAN ZENO WAY
KIFER RD.
LAWRENCE EXPRESSWAY
(E) ONE STORY OFFICE
BUILDING
(E) ONE STORY OFFICE
BUILDING
SOUTH PARCEL
2 ACRES
SITE PLAN 1/40 SCALE
MARCH 10, 2022 LU35
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1" = 40'-0"LU35
1 STE PLAN
EVA
EVASECONDARY BIKE PATH
SCALE : 1” = 80’
TREE #696
TREE #706
TREE #696
TREE #706
SAN ZENO W
AY
KIFER RD.
LAWRENCE EXPRESSWAY
EXISTING OFFICE
BUILDING
1150 KIFER RD
SOUTH PARCEL
2.00 ACRES
EXISTING OFFICE
BUILDING
1170 KIFER RD
NORTH PARCEL
3.82 ACRES
PROPOSED 8 STORY
RESIDENTIAL BUILDING
OVERALL SITE PLAN
MAY 24, 2023 LU4
170 SAN ZENO WAY
SUNNYVALE, CA 94086
PROPOSED GATEWAY SIGNAGE LOCATION,
SEE EXHIBIT SHEETS FOR GATEWAY SIGNAGE
DESIGN AND DIMENSIONS.
40FT X 40FT CORNER VISION TRIANGLE
PROPOSED PROPERTY LINES
EXISTING PROPERTY LINES
PROPOSED WAYFINDING SIGNAGE,
SEE EXHIBIT SHEETS FOR GATEWAY SIGNAGE
DESIGN AND DIMENSIONS,
EV
EV
EV
SL
AL
SAN ZENO WAY
KIFER RD.
LAWRENCE EXPRESSWAY
(E) ONE STORY OFFICE
BUILDING
(E) ONE STORY OFFICE
BUILDING
SOUTH PARCEL
2 ACRES
SITE PLAN 1/40 SCALE
MARCH 10, 2022 LU35
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1" = 40'-0"LU35
1 STE PLAN
20’ 40’ 80’ 160’
Attachment 6
SITE PHOTOS
N SAN ZENO WA
Y
1 2
3 4
1 AERIAL SITE VIEW
3 SE SAN ZENO WAY LOOKING NORTH
2 NE SAN ZENO WAY LOOKING SOUTH
4 EXISTING OFFICE COURTYARD
5 LU SUBMITTAL 05 JULY 05, 2023
PROJECT SITE
Attachment 6
SITE PHOTOS
N SAN ZENO WA
Y
1 2
4 3
2 SOUTH ACCESS TO SITE1 NORTH ACCESS TO SITE
4 EAST PROPERTY EDGE3 WEST PROPERTY EDGE
(SAVOY - NEIGHBORING PROPERTY)
6 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
CONTEXT MAP
7 LU SUBMITTAL 05 JULY 05, 2023
KIFER ROAD
LAWRENCE
EXPRESSWAY
SONORA CT.
SAN ZENO WAY
LAWRENCE CALTRAIN
STATION
1150-1170 KIFER ROAD
PROJECT SITE
Attachment 6
NORTH EAST CORNER VIEW
8 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
MAIN ENTRY VIGNETTE
9 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
NORTH ELEVATION VIEW
10 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
TOWNHOMES VIGNETTE
11 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
NORTH PATH VIGNETTE
12 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
2ND ENTRY VIGNETTE
13 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
WEST VIGNETTE
14 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
SOUTH ELEVATION VIEW
15 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
SOUTHEAST VIEW
16 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
SHARED USE PATH VIGNETTE - WEST
17 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
SHARED USE PATH VIGNETTE - EAST
18 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
ZONING DIAGRAMS
19 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
LAND COVERAGE
N
LAND COVERAGE
20 LU SUBMITTAL 05 JULY 05, 2023
185.20'200.00'
LAND COVERAGE
AUGUST 21, 2022 LU12
170 SAN ZENO WAY
SUNNYVALE, CA 94086
LAND COVERAGE
REQUIRED: NOT TO EXCEED 80%
LOT SF: 87,156 SF
PROVIDED: LAND COVERAGE: 65%
PROPOSED GROUND ST ORY FOOTPRINT: 56,856 SF
EXISTING OFFICE SITE LAND COVERAGE
EXISTING LOT AREA: 253,702 SF
1 150 KIFER RD PARCEL: 114,094 SF (2.62 ACRES)
1 170 KIFER RD PARCEL: 139,608 SF (3.20 ACRES)
PROPOSED MODIFIED SITE AREA: 166,546 SF (3.82 ACRES)
TOTAL LAND COVERAGE: 51,494 SF
EXISTING BUILDING FOOTPRINT: 31%
1 150 KIFER RD. GROUND STORY FOOTPRINT: 23,142 SF
1170 KIFER RD. GROUND STORY FOOTPRINT: 28,352 SF
SETBACK REQUIREMENTS
FRONT YARD: 15FT MIN SIDE YARD: 10FT MIN REAR YARD: 10FT MIN PUBLIC SHARED USE PATH: 22FT MIN 10’
10’ 15’
22’
FRONT YARDSAN ZENO WAY
PUBLIC SHARED-USE PATH
SIDE YARD
REAR YARD
1150 KIFER RD.
EXISTING OFFICE
BUILDING
1170 KIFER RD.
EXISTING OFFICE
BUILDING
PROPOSED BUILDING
FOOTPRINT
Attachment 6
BUILDING HEIGHT
21 LU SUBMITTAL 05 JULY 05, 2023
ELEVATION DIAGRAMS
MARCH 02, 2023 LU19
170 SAN ZENO WAY
SUNNYVALE, CA 94086
92’-2”
100’-0” MAX ALLOWED BUILDING HEIGHT
SAN ZENO T.O. CURB
MAX ALLOWED BUILDING HEIGHT
T.O. PARAPET
58’-4”
158’-4”
148’-6”
ZONING BUILDING HEIGHT
Attachment 6
SETBACK - SAN ZENO WAY
22 LU SUBMITTAL 05 JULY 05, 2023
FRONT YARD SETBACK
MAX PROPOSED
ADDITIONAL SETBACK
MAX PROPOSED
ADDITIONAL SETBACK
SAN ZENO WAY SAN ZENO WAY SAN ZENO WAY SAN ZENO WAY
FRONT YARD SETBACKSETBACK ABOVE 50FT SETBACK ABOVE 50FTFRONT YARD SETBACK FRONT YARD SETBACK
FRONT YARD SETBACKFRONT YARD SETBACK
R.O.W.R.O.W.
SETBACK ABOVE 50FTSETBACK ABOVE 50FT
ZONING SETBACK REQ’D ABOVE 50’
PLAN
PROPOSED SETBACK 1st & 2nd STORIES
PLAN
PROPOSED SETBACK 3rd, 5th-7th STORIES
PLAN
PROPOSED SETBACK 4th STORY
PLAN
PROPOSED SETBACK 8th STORY
WALL SECTION
REQUIRED SETBACK - FRONT YARD
WALL SECTION
PROPOSED SETBACK - FRONT YARD
PROVIDED SETBACK AREA: 1,100 SF
REQ’D SETBACK AT FRONT YARD < 50FT : 15FT
REQ’D SETBACK AT FRONT YARD > 50FT: 30 FT
TOTAL SETBACK AREA REQ’D ABOVE 50FT: 6,220 SF
TOTAL PROVIDED SETBACK AREA: 7,585 SF
PROVIDED SETBACK AREA PER FLR: 840 SF
MAX PROPOSED SETBACK: 13FTMAX PROPOSED ADDITIONAL SETBACK: 20FTMAX PROPOSED ADDITIONAL SETBACK: 12FT MAX PROPOSED SETBACK: 17FT PROVIDED SETBACK AREA: 1,300 SF PROVIDED SETBACK AREA : 1,298 SF 15’12’ 20’
12’
20’ 17’
15’ 15’ 15’15’ 15’
15’15’
15’15’
50’50’
31’
PROPOSED SETBACK LINE
CITY STAFF CONFIRMED THE USE OF A DBL WAIVER CAN BE USED LSAP DESIGN GUIDELINE: RB-UDG5
Attachment 6
SETBACK - SHARED-USE PATH
23 LU SUBMITTAL 05 JULY 05, 2023
M
170 S
SUNNYVA
SETBACKS
MARCH 7, 2022 LU13
170 SAN ZENO WAY
SUNNYVALE, CA 94086
SETBACKS
MARCH 7, 2022 LU13
170 SAN ZENO WAY
SUNNYVALE, CA 94086
OVERALL AREA REQUIRED AT SETBACK ABOVE 50FT: 7,417 SF
OVERALL AREA PROVIDED AT SETBACK ABOVE 31 FT : 13.600 SF ZONING SETBACK REQ’D ABOVE 50’ ZONING SETBACK REQ’D ABOVE 50’ ZONING SETBACK REQ’D ABOVE 50’
PROPOSED SETBACK LINEPROPOSED SETBACK LINE
SETBACK ABOVE 50FT
SETBACK ABOVE 50FT
SHARED-USE PATH SETBACK
SHARED-USE PATH SETBACK
SECONDARY BIKE PATH
R.O.W.
22’97’
SECONDARY PATH
R.O.W.
SETBACK ABOVE 50FT
22’15’22’15’
50’
PLAN
PROPOSED SHARED-USE PATH SETBACK
WALL SECTION
PROPOSED SHARED-USE PATH SETBACK
WALL SECTION
REQUIRED SHARED-USE PATH SETBACK
N
31’-6”
CITY STAFF CONFIRMED THE USE OF A DBL WAIVER CAN BE USED Attachment 6
ACTIVE USE
N
EXTERIOR COMMUNITY PLAZA
ACTIVE USE
24 LU SUBMITTAL 05 JULY 05, 2023
59'
ACTIVE - USE
AUGUST 05, 2022 LU14B
170 SAN ZENO WAY
SUNNYVALE, CA 94086
GROUND STORY ACTIVE USE
SAN ZENO WAY ACTIVE USE
SHARED-USE SECONDARY PATHWAYENLARGED BICYCLE & PEDESTRIAN PATHWAY DN
ELEV 1 & 2
OFFICE PARKING
ELEV 3
UTILITY
1143 SF
MAINTENANCE
479 SF
ELECTRICAL
TRASH
89 STALLS
RAMP
LOBBY
ELEV 4
RR
OFFICE
BOH
PACKAGE
LOBBY
MAIL
PARLOR
BOILER
TRASH
3 BED TOWNHOME 3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
LOADING ZONE
OFFICE PARKING
ENTRY
RAMP
621 SF
TRANSFORMERS
379 SF
ELECTRICAL
UP
233 SF
DOM WATER
296 SF
FIRE PUMP
511 SF
ELECTRICAL
123 4 5 67 89 10 11 12 13 14 15 16 17
18 19
20 21
22 23 2425 26 2728 2930 3132 33 3435 36 3738 39 40
41 42
43 44
45 54 53 5251 50 4948 47 46 63 62 6160 59 5857 56 55 65 64 77 78 7980 81 8283 84 85 68 69 7071 72 7374 75 76 66 67 ELEC
ELEC
GROUND STORY
JULY 20, 2022 LU37
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU37
1 GROUND STORY
N
DN
ELEV 1 & 2
OFFICE PARKING
ELEV 3
UTILITY
1143 SF
MAINTENANCE
479 SF
ELECTRICAL
TRASH
89 STALLS
RAMP
LOBBY
ELEV 4
RR
OFFICE
BOH
PACKAGE
LOBBY
MAIL
PARLOR
BOILER
TRASH
3 BED TOWNHOME 3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
LOADING ZONE
OFFICE PARKING
ENTRY
RAMP
621 SF
TRANSFORMERS
379 SF
ELECTRICAL
UP
233 SF
DOM WATER
296 SF
FIRE PUMP
511 SF
ELECTRICAL
123 4 5 67 89 10 11 12 13 14 15 16 17
18 19
20 21
22 23 2425 26 2728 2930 3132 33 3435 36 3738 39 40
41 42
43 44
45 54 53 5251 50 4948 47 46 63 62 6160 59 5857 56 55 65 64 77 78 7980 81 8283 84 85 68 69 7071 72 7374 75 76 66 67 ELEC
ELEC
GROUND STORY
JULY 20, 2022 LU37
170 SAN ZENO WAY
SUNNYVALE, CA 94086
ORY
N
SEMI-PRIVATE RESIDENTIAL UNITS
ACTIVE USE PROGRAMMED SPACE ALONG SAN ZENO
(MAIN ENTRY, LEASING OFFICE, COMMUNITY GATHERING SPACE AND EXTERIOR COMMUNITY PLAZA)
ACTIVE-USE SECONDARY BICYCLE & PEDESTRIAN PATHWAY
BICYCLE & PEDESTRIAN PATHWAY
Attachment 6
USEABLE OPEN SPACE AREA
FOURTH STORY OPEN SPACE
25 LU SUBMITTAL 05 JULY 05, 2023
3 -
5 6
5042 677 (50% of 1,354)1259 6,978
USEABLE OPEN SPACE AREA
MAY 10, 2023 LU25
170 SAN ZENO WAY
SUNNYVALE, CA 94086
15,614
15,614
9333
21,173
3 -
5 6
5042 677 (50% of 1,354)1259 6,978
USEABLE OPEN SPACE AREA
MAY 10, 2023 LU25
170 SAN ZENO WAY
SUNNYVALE, CA 94086
15,614
15,614
9333
21,173
OPEN SPACE AREA
AN OUTDOOR OR UNENCLOSED AREA ON THE GROUND, OR ON A ROOF, BALCONY, DECK, PORCH, POOL
AREA, PATIO OR TERRACE OR RECREATION BUILDING, WHEN DESIGNED AND ACCESSIBLE FOR OUTDOOR
LIVING, RECREATION, PEDESTRIAN ACCESS OR LANDSCAPING, BUT EXCLUDING PARKING FACILITIES, DRIVEWAYS, UTILITIES, SERVICE OR STORAGE AREAS.
REQUIRED:
50 SF PER UNIT = 11,200 SF
PROVIDED: 4TH STORY COURTYARD AREA: 13,616 SF
AREA ATLEAST 12FT IN ANY DIRECTION AND GREATER THAN 200 SQFT: 5,042 SF FRONT YARD AREA (50% COUNTED TOWARDS USEABLE OPEN SPACE): 677 SF TOTAL OPEN SPACE: 19,335 SF
4TH STORY COURTYARD AREA: 13,616 SF
GROUND STORY OPEN SPACE
OUTDOOR GROUND AREA: 5,042 SF
FRONT YARD AREA (50%) : 677 SF
Attachment 6
SHEET OMITTED
26 LU SUBMITTAL 05 JULY 05, 2023
Attachment 6
GROUND STORY LANDSCAPE AREA
4TH STORY LANDSCAPE AREA 8TH STORY LANDSCAPE AREA
N
N N
LANDSCAPE AREA
27 LU SUBMITTAL 05 JULY 05, 2023
9,770 SF
10,253 SF
4,824 SF
WEST COURTYARD VEGETATION: 3,209 SF
WEST COURTYARD HARDSCAPE: 1,615 SF
WEST COURTYARD TOTAL: 4,824 SF
EAST COURTYARD VEGETATION: 2,407 SF
10,115 SF
8TH STORY AMENITY DECKS VEGETATION AREA:
8TH STORY AMENITY DECKS LANDSCAPE AREA: TOTAL 350 SF
TOTAL 350 SF
1,720 SF (EXCLUDED)
LANDSCAPE AREA
AUGUST 21, 2022 LU23
170 SAN ZENO WAY
SUNNYVALE, CA 94086
LANDSCAPE AREA
LSAP MINIMUM :
INCENTIVE :
20% (17,433 SF)
25%-30% (21,791 SF) = 3 POINTS
35% (30,507 SF) = 5 POINTS
PROVIDED : GROUNND STORY =
4TH STORY =
8TH STORY =
TOTAL =
17,855 SF
14,856.5 SF
2,070 SF
34,782 SF (40%) = 5 POINTS
SITE AREA 87,165 SF
9,770 SF
10,253 SF
4,824 SF
WEST COURTYARD VEGETATION: 3,209 SF
WEST COURTYARD HARDSCAPE: 1,615 SF
WEST COURTYARD TOTAL: 4,824 SF
EAST COURTYARD VEGETATION: 2,407 SF
10,115 SF
8TH STORY AMENITY DECKS VEGETATION AREA:
8TH STORY AMENITY DECKS LANDSCAPE AREA: TOTAL 350 SF
TOTAL 350 SF
1,720 SF (EXCLUDED)
LANDSCAPE AREA
AUGUST 21, 2022 LU23
170 SAN ZENO WAY
SUNNYVALE, CA 94086
LANDSCAPE AREA
LSAP MINIMUM :
INCENTIVE :
20% (17,433 SF)
25%-30% (21,791 SF) = 3 POINTS
35% (30,507 SF) = 5 POINTS
PROVIDED : GROUNND STORY =
4TH STORY =
8TH STORY =
TOTAL =
17,855 SF
14,856.5 SF
2,070 SF
34,782 SF (40%) = 5 POINTS
SITE AREA 87,165 SF
9,770 SF
10,253 SF
4,824 SF
WEST COURTYARD VEGETATION: 3,209 SF
WEST COURTYARD HARDSCAPE: 1,615 SF
WEST COURTYARD TOTAL: 4,824 SF
EAST COURTYARD VEGETATION: 2,407 SF
10,115 SF
8TH STORY AMENITY DECKS VEGETATION AREA:
8TH STORY AMENITY DECKS LANDSCAPE AREA: TOTAL 350 SF
TOTAL 350 SF
1,720 SF (EXCLUDED)
LANDSCAPE AREA
AUGUST 21, 2022 LU23
170 SAN ZENO WAY
SUNNYVALE, CA 94086
LANDSCAPE AREA
LSAP MINIMUM :
INCENTIVE :
20% (17,433 SF)
25%-30% (21,791 SF) = 3 POINTS
35% (30,507 SF) = 5 POINTS
PROVIDED : GROUNND STORY =
4TH STORY =
8TH STORY =
TOTAL =
17,855 SF
14,856.5 SF
2,070 SF
34,782 SF (40%) = 5 POINTS
SITE AREA 87,165 SF
LANDSCAPE AREA
A PORTION OF A SITE PLANTED WITH VEGETATION UTILIZED FOR SCREENING OR ORNAMENTATION. FOR
PURPOSES OF COMPUTATION OF LANDSCAPED AREA AS THAT TERM IS USED IN THIS TITLE, AUTOMOBILE
PARKING AREAS, STORAGE AREAS, VEHICULAR WAYS AND SPECIFICALLY PERMITTED UNENCLOSED USES SHALL NOT BE CONSIDERED AS LANDSCAPING.
REQUIRED:
20% OF LOT (87,156 SF x .20) = 17,431 SF
INCENTIVE: 35% = 5 POINTS (87,156 SF x .35) = 30,505 SF PROVIDED: GROUND STORY: 20,023 SF
4TH ST ORY: 14,939 SF
8TH ST ORY: 350 SF
TOTAL: 35,312 SF = 40.5%
MAIN ENTRANCE & TOWNHOME WALK (NORTH & EAST): 9,770 SF
SHARED USE PATH: 10,253 SF
WEST AMENITY DECK: 4,824 SF
EAST AMENITY DECK: 10,115 SF
AMENITY DECK PLANTERS: 350 SF
TOTAL LANDSCAPED AREA PROVIDED: 35,312 SF
35,312 SF = 40.5% OF GROSS FLOOR AREA (87,156 SF)SHARED USE PATH: 10,253 SF EAST AMENITY DECK: 10,115 SF
MAIN ENTRANCE & TOWNHOME WALK (NORTH & EAST): 9,770 SF
WEST AMENITY DECK: 4,824 SF AMENITY DECK PLANTERS: 350 SF Attachment 6
SITE CIRCULATION
N
28 LU SUBMITTAL 05 JULY 05, 2023
SITE CIRCULATION
SITE CIRCULATION
MARCH 02, 2023 LU17
170 SAN ZENO WAY
SUNNYVALE, CA 94086
PEDESTRIAN CIRCULATION
BICYCLE CIRCULATION
VEHICLE CIRCULATION
VEHICLE PARKING
CLASS II BICYCLE PARKING
PEDESTRIAN ENTRY
CIRCULATION LEGEND
1150 KIFER RD.
EXISTING OFFICE
BUILDING
1170 KIFER RD.
EXISTING OFFICE
BUILDING
RESIDENTIAL PARKING
TO TRAIN STATION
OFFICE ENTRY
PEDESTRIAN CONNECTION
KIFER RD.
SAN ZENO WAY
OFFICE PARKING
P
P P
P
P
P
P
P
P
Attachment 6
HORIZONTAL BUILDING ARTICULATION
CITY STAFF CONFIRMED THE USE OF A DBL WAIVER CAN BE USED LSAP DESIGN GUIDELINE: BMA-UDG4
29 LU SUBMITTAL 05 JULY 05, 2023
< 175’ < 175’
124’43’ 50’
165’
50’70’
70’ 49’ 11’ 27’
70’ 50’ 48’ 62’
82’
40’
1’- 6”
2’- 4” 2’- 4” 4’- 6”
1’- 6”
HORIZONTAL BUILDING ARTICULATION
N
INTERPRETED HORIZONTAL MODULE DIAGRAM
< 175’
< 175’
< 175’
< 175’
< 175’
< 175’
< 175’
N
PROPOSED HORIZONTAL MODULE DIAGRAM - 1ST - 3RD LVLS
EVERY 175 LINEAR FEET OF FACADE SHALL HAVE A MINIMUM WALL RECESS / OPENING OF AT LEAST 15FT WIDE BY 15FT DEEP (AREA: 225 SF)
PER LSAP BMA-UDG4
Attachment 6
HORIZONTAL BUILDING ARTICULATION
CITY STAFF CONFIRMED THE USE OF A DBL WAIVER CAN BE USED LSAP DESIGN GUIDELINE: BMA-UDG4
30 LU SUBMITTAL 05 JULY 05, 2023
HORIZONTAL BUILDING ARTICULATION
10’10’
8’ 10’
94’
N N
INTERPRETED HORIZONTAL MODULE DIAGRAM PROPOSED HORIZONTAL MODULE DIAGRAM 4TH - 8TH LVLS PER LSAP BMA-UDG4
EVERY 175 LINEAR FEET OF FACADE SHALL HAVE A MINIMUM WALL RECESS / OPENING OF AT LEAST 15FT WIDE BY 15FT DEEP (AREA: 225 SF)
THE PROPOSED WALL RECESS / OPENINGS EXCEED THE MINIMUM DIMENSION & AREA
REQUIREMENT, FURTHER INCREASING THE NET VOLUME REDUCTIONS
SOUTH ELEVATION
REQUIRED VOLUME REDUCTION: 225 SF X 8 ST ORIES = 3,600 SF PROPOSED VOLUME REDUCTION: 67,500 SF
NORTH ELEVATION
REQUIRED VOLUME REDUCTION: 225 SF X 8 ST ORIES = 3,600 SF PROPOSED VOLUME REDUCTION: 4,950 SF
EAST & WEST ELEVATION
=165 LINEAR FEET
>175 LINEAR FEET EXEMPT FROM REQUIREMENT
< 175’ < 175’ < 175’
124’43’ 50’
< 175’
165’
< 175’ < 175’
50’70’
70’ 87’
70’ 100’
< 175’
< 175’ < 175’
< 175’
< 175’
82’
40’
Attachment 6
VERTICAL MODULES DIAGRAMS
CITY STAFF CONFIRMED THE USE OF A DBL WAIVER CAN BE USED LSAP DESIGN GUIDELINE: BMA-UDG1
31 LU SUBMITTAL 05 JULY 05, 2023
ELEVATION DIAGRAMS
JULY 20, 2022 LU20
170 SAN ZENO WAY
SUNNYVALE, CA 94086
ELEVATION
MARCH 02, 2023
170 SAN ZENO WAY
SUNNYVALE, CA 94086
ELEVATION DIAGRAMS
JULY 20, 2022 LU20
170 SAN ZENO WAY
SUNNYVALE, CA 94086
10 FT
BEYOND
10 IN
BEYOND
4 FT - 6 IN BEYOND
10 FT
BEYOND
94 FT
BEYOND
94 FT
BEYOND
20 FT
BEYOND
20 FT
BEYOND
WEST ELEVATION
NORTH ELEVATIONEAST ELEVATION
SOUTH ELEVATION
VERTICAL
MODULE
VERTICAL
MODULE
VERTICAL
MODULE
VERTICAL
MODULE
VERTICAL
MODULE
VERTICAL
MODULE
VERTICAL
MODULE
VERTICAL
MODULE
VERTICAL
MODULE
VERTICAL
MODULE
VERTICAL
MODULE
VERTICAL
MODULE
100’ -0”50’ -0”
46’ -6” 40’ -6”
37’ - 0”
Attachment 6
ELEVATION DIAGRAMS
32 LU SUBMITTAL 05 JULY 05, 2023
ELEVATION DIAGRAMS
JULY 20, 2022 LU20
170 SAN ZENO WAY
SUNNYVALE, CA 94086
ELEVATION
MARCH 02, 2023
170 SAN ZENO WAY
SUNNYVALE, CA 94086
ELEVATION DIAGRAMS
JULY 20, 2022 LU20
170 SAN ZENO WAY
SUNNYVALE, CA 94086
WEST ELEVATION
NORTH ELEVATIONEAST ELEVATION
SOUTH ELEVATION
MIDDLE
MIDDLE
MIDDLEMIDDLE
BASEBASE
BASEBASE
TOPTOP
TOPTOP
Attachment 6
ROOF HEIGHT VARIATION DIAGRAMS
WEST ELEVATIONSOUTH ELEVATION
LSAP DESIGN GUIDELINE: BMA-UDG5
33 LU SUBMITTAL 05 JULY 05, 2023
ELEVATION DIAGRAMS
JULY 20, 2022 LU20
170 SAN ZENO WAY
SUNNYVALE, CA 94086
ELEVATION
MARCH 02, 2023
170 SAN ZENO WAY
SUNNYVALE, CA 94086
ELEVATION DIAGRAMS
JULY 20, 2022 LU20
170 SAN ZENO WAY
SUNNYVALE, CA 94086
46’ -6”
31’ -10” 31’ -10” 31’ -10” 31’ -10” 61’ -9” 75’ -10” 78’ -10” 46’ -4” 25’ -8” 75’ -6” 45’ -9” 27’ -6”37’ -10” 50’ -0” 42’ -3” 27’ -2” 31’ -10”
NORTH ELEVATIONEAST ELEVATION
HEIGHT LIMIT
100’ -0”
15’
85’-0”
HEIGHT LIMIT
100’ -0”
15’
85’-0”
Attachment 6
BUILDING CONTEXT
EAST SITE ELEVATION
EXISTING OFFICE BUILDINGEXISTING OFFICE
BUILDING
SAN ZENO WAY
LAWRENCE
EXPRESSWAY
34 LU SUBMITTAL 05 JULY 05, 2023
NORTH SITE ELEVATION
61’-6”
92’-2”
32’
18’
NEIGHBORING BUILDING
ELEVATION FOR REFERENCE
KIFER RD
LAWRENCE
EXPRESSWAY
Attachment 6
N
WINDOW OPENINGS - SAVOY
35 LU SUBMITTAL 05 JULY 05, 2023
BUILDING WINDOW DIAGRAM
EXISTING ADJACENT BUILDING WINDOW OPENINGS (SAVOY)
PROPOSED BUILDING WINDOW OPENINGS
BETWEEN BUILDINGS
66 FT
Attachment 6
36 LU SUBMITTAL 05 JULY 05, 2023
CIVIL
Attachment 6
June 14,2023
Attachment 6
June 14,2023
Attachment 6
June 14,2023
20'x27' RESIDENTIAL
STAGING AREA
10'x27'
CONCRETE PAD
Attachment 6
June 14,2023
Attachment 6
June 14,2023
Attachment 6
June 14,2023
Attachment 6
June 14,2023
Attachment 6
May 22, 2023
1150-1170 Kifer Road
SUNNYVALE, CA
BKF ENGINEERS
1730 N. FIRST STREET
SUITE 600
SAN JOSE, CA 95112
(408) 467-9100
www.bkf.com
June 14,2023
Attachment 6
June 14,2023
Attachment 6
46 LU SUBMITTAL 05 JULY 05, 2023
LANDSCAPE
Attachment 6
47 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
1” = 60’-0”
OVERALL SITE PLAN
KEY MAP EXISTING CONDITIONS
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
08.05. 2022
# REVISION LIST
2325 Third Street #210
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
L020
1" = 30'-0"
OVERALL SITE PLAN -
EXISTING PLANTING ARE
EXISTING SITE PLANTING AREAS
PROPOSED PLANTING AREAS
SEE SHEET 2 OF 2: PROPOSED LOT 1 RESIDENTIAL BUILDING
SEE SHEET 1 OF 2 : EXISTING & PROPOSED LOT2 OFFICE BUILDING Attachment 6
48 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
DN
UP
UP
DN
DN
UP
UP
UP
EASEMENTS SEE CIVIL PLANS
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
2325 Third Street #210
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L010
1" = 30'-0"
OVERALL SITE KEY PLAN
OFFICE LANDSCAPE AREA
PER SMC 19.35.090
EXISTING LOT 2 = 166,546 SQFT
EXISTING LANDSCAPE AREA IS 48,299 SQFT
PROPOSED LANDSCAPE AREA IS 11,003 SQFT (6 NEW TREES)
PROPOSED LANDSCAPE AREA WITH UNTOUCHED EXISTING = 47,333 SQFT LANDSCAPE AREA PERCENTAGE = 28.4%
1” = 60’-0”
LANDSCAPE AREA
LOT 2 OFFICE BUILDING
UP
DN
DN
EASEMENTS SEE CIVIL PLANS
SH
SH
PR
DA
SC
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch O
OFFICE LANDSCAPE AREA
PER SMC 19.35.090
EXISTING LOT 2 = 166,546 SQFT
EXISTING LANDSCAPE AREA IS 48,299 SQFT
PROPOSED LANDSCAPE AREA IS 11,003 SQFT (6 NEW TREES)
PROPOSED LANDSCAPE AREA WITH UNTOUCHED EXISTING = 47,333 SQFT LANDSCAPE AREA PERCENTAGE = 28.4%
LANDSCAPE AREA
Attachment 6
49 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
DN
UP
UP
DN
DN
UP
UP
UP
EASEMENTS SEE CIVIL PLANS
EASEMENTS SEE CIVIL PLANS
EASEMENTS SEE CIVIL PLANS
4TH LEVEL
8TH LEVEL
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
2325 Third Street #210
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L011
1" = 30'-0"
OVERALL SITE KEY PLAN
PER SMC 19.37.060 (a) (3)
PROPOSED LANDSCAPE AREAS
GROUND LEVEL LANDSCAPE AREA IS 20,023 SQFT (42 NEW TREES) 4TH LEVEL LANDSCAPE AREA IS 14,939 SQFT (47 NEW TREES)
8TH LEVEL LANDSCAPE AREA IS 350 SQFT (NO NEW TREES)
TOTAL LANDSCAPE AREA = 35,312 SQFT
REQUIRED - 1 TREE / 1,000 SQFT = 35 REQUIRED TREES
REQUIRED REPLACEMENT TREES = 16
TOTAL REQUIRED = 51
TOTAL TREES PLANTED = 89
1” = 60’-0”
LANDSCAPE AREA
PROPOSED LOT 1 RESIDENTIAL BUILDING
UP
DN
DN
EASEMENTS SEE CIVIL PLANS
SH
SH
PR
DA
SC
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch O
PER SMC 19.37.060 (a) (3)
PROPOSED LANDSCAPE AREAS
GROUND LEVEL LANDSCAPE AREA IS 20,023 SQFT (42 NEW TREES) 4TH LEVEL LANDSCAPE AREA IS 14,939 SQFT (47 NEW TREES)
8TH LEVEL LANDSCAPE AREA IS 350 SQFT (NO NEW TREES)
TOTAL LANDSCAPE AREA = 35,312 SQFT
REQUIRED - 1 TREE / 1,000 SQFT = 35 REQUIRED TREES
REQUIRED REPLACEMENT TREES = 16
TOTAL REQUIRED = 51
TOTAL TREES PLANTED = 89
EASEMENTS SEE CIVIL PLANS
EASEMENTS SEE CIVIL PLANS
4TH LEVEL
8TH LEVEL
ISSUES
#
4TH LEVEL
8TH LEVEL
UP
EASEMENTS SEE CIVIL PLANS
EASEMENTS SEE CIVIL PLANS
4TH LEVEL
8TH LEVEL
ISSUES
#
LANDSCAPE AREA
Attachment 6
50 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
REPORT NOTES AND PLAN
LANDSCAPE - ARBORIST REPORT
NOTE: FOR MORE DETAILS SEE FULL ARBORIST REPORT
Attachment 6
51 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
TREE PROTECTION DETAILS
LANDSCAPE - ARBORIST REPORT
NOTE: FOR MORE DETAILS SEE FULL ARBORIST REPORT
Attachment 6
52 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE SITE PLAN
TREE #709
TREE #705
TREE #560
TREE #656
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702
TREE #697
TREE #696
TREE #706
TREE #704
TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
TREE #561
TREE #562
TREE #595
TREE #20
STUMP NO TAG
LEGEND
EXISTING
TREES TO BE PROTECTED
TREE TO BE REMOVED AND
REQUIRED TO REPLACE
TREE TO BE REMOVED
TREE PROTECTION FENCE
REQUIRED TREES TO REPLACED
TREE TAG # TRUNK DIAMETER (IN) (QTY) PROPOSED
REPLACEMENT TREE
529 19 (1) 36"
532 18 (1) 36"
549 34 (2) 36"
548 31 (2) 36"
551 30 (2) 36"
550 35 (2) 36"
595 15 (1) 36"
602 12 (1) 36"
618 13 (1) 36"
635 13 (1) 36"
636 12 (1) 36"
644 12 (1) 36"
TOTAL (16) 36"
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
08.05. 20
# REVIS
KIFER DEVELOPMENT
1/16" = 1
TREE PROTE
REMOVAL PL
SHEET L101 SHEET L101
NOTE: ALL PROPOSED TREES ARE 36" BOX; PLEASE SEE
PLANTING PLAN SHEETS
1/32” = 1’-0”
TREE PROTECTION & REMOVAL PLAN 1 OF 2
SEE SHEET 2 OF 2 SEE SHEET
2 OF 2
TREE #635
TREE
#637
TREE
#638
TREE
#639
TREE
#640
TREE
#641
TREE
#642
TREE
#644 TREE
#645
TREE
#647
TREE
#648
TREE #23
TREE #25
TREE #26
TREE #29
TREE #596
TREE #529
TREE #530
TREE #531 TREE #532
TREE #533
TREE
#634
TREE
#633
TREE
#632
TREE
#631
TREE
#630
TREE
#629
TREE
#628
TREE
#624
TREE
#623
TREE
#622
TREE
#621
TREE
#620
TREE
#614
TREE
#649
TREE
#650
TREE
#651
TREE
#599
TREE
#600
TREE
#601
TREE
#602
TREE
#603
TREE
#604
TREE
#607
TREE
#609
TREE
#610
TREE
#611
TREE
#612
TREE
#613
TREE
#614 TREE
#615
TREE
#616
TREE
#547
TREE
#546
TREE
#545
TREE
#524
TREE
#543
TREE
#544TREE
#541
TREE
#540
TREE
#538
TREE
#532
TREE
#536
TREE
#535
TREE
#534
TREE
#539
TREE
#548
TREE
#549
TREE
#551
TREE
#550
TREE
#552
TREE
#553
TREE
#554
TREE
#555
TREE
#556
TREE
#557
TREE
#558
#653 TREE
#654
TREE
#655
TREE
#618
TREE
#617
TREE
#626
TREE
#627
TREE
#625
TREE
#608
TREE
#605
TREE
#606
TREE
#597
TREE
#598
TREE
#559
LEGEND
EXISTING
TREES TO BE PROTECTED
TREE TO BE REMOVED AND
REQUIRED TO REPLACE
TREE TO BE REMOVED
TREE PROTECTION FENCE
REQUIRED TREES TO REPLACED
TREE TAG # TRUNK DIAMETER (IN) (QTY) PROPOSED
REPLACEMENT TREE
529 19 (1) 36"
532 18 (1) 36"
549 34 (2) 36"
548 31 (2) 36"
551 30 (2) 36"
550 35 (2) 36"
595 15 (1) 36"
602 12 (1) 36"
618 13 (1) 36"
635 13 (1) 36"
636 12 (1) 36"
644 12 (1) 36"
TOTAL (16) 36"
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
08.05. 2022
# REVISION
KIFER DEVELOPMENT
1/16" = 1'-0"
TREE PROTEC
REMOVAL PLA
NOTE: ALL PROPOSED TREES ARE 36" BOX; PLEASE SEE
PLANTING PLAN SHEETS
trees proposed for removal, the following guidelines shall apply (with exceptio ns considered for dead, unhealthy or hazardous trees or emergency situations):
Tree to be Removed Replacement Tree(s)
12” - 18” diameter
(36”-56” circumference)
One 24” box tree, or
Three 15-gallon trees
18” - 24” diameter
(56” -75” circumference)
One 36” box tree, or
Two 24” box trees
Over 24” diameter
(greater than 75” circumference)
One 48” box tree, or
Two 36” box trees, or
Four 24” box trees
If space permits, smaller size container trees are generally preferred over larger size boxed trees to maximize the quantity of replacement trees. Additionally, smaller size container trees usually adapt easier to soil conditions and over time may exceed the size of larger size boxed trees. However, if immediate screening or visual impac t is desired and sp ace is limited, larger boxed trees may be required. Where insufficient space is available to plant all or some of the required replacement trees or other site conditions or uses limit the feasibility of replacement trees, the following t ree replacement in -lieu fees shall be assessed.
Tree removal on properties without a Planning development application:
Replacement Tree Tree Replacement
In-Lieu Fee*
Each 24” box tree $441
Each 36” box tree $883
Each 48” box tree $1,765
* This fee does not include the tree removal permit fee.
PG 3 OF THE TREE REPLACEMENT REQUIREMENTS - HTTPS://WWW.SUNNYVALE.
CA.GOV/HOME/SHOWPUBLISHEDDOCUMENT/1420/637957155372030000 Attachment 6
53 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 37
LANDSCAPE SITE PLAN
TREE #560
TREE #636
TREE #635
TREE
#637
TREE
#638
TREE
#639
TREE
#640
TREE
#641
TREE
#642
TREE
#643
TREE
#644
TREE
#646
TREE
#645
TREE
#647
TREE
#648
TREE #21
TREE #20
TREE #23
TREE #25
TREE #26
TREE #29
TREE #596
TREE #529
TREE #530
TREE #531 TREE #532
TREE #533
TREE
#634
TREE
#633
TREE
#632
TREE
#631
TREE
#630
TREE
#629
TREE
#628
TREE
#624
TREE
#623
TREE
#622
TREE
#621
TREE
#620
TREE
#614
TREE
#649
TREE
#650
TREE
#651
TREE
#599
TREE
#600
TREE
#601
TREE
#602
TREE
#603
TREE
#604
TREE
#607
TREE
#609
TREE
#610
TREE
#611
TREE
#612
TREE
#613
TREE
#614 TREE
#615
TREE
#616
TREE
#547
TREE
#546
TREE
#545
TREE
#524
TREE
#543
TREE
#544TREE
#541
TREE
#540
TREE
#538
TREE
#532
TREE
#536
TREE
#535
TREE
#534
TREE
#539
TREE
#548
TREE
#549
TREE
#551
TREE
#550
TREE
#552
TREE
#553
TREE
#554
TREE
#555
TREE
#556
TREE
#557
TREE
#558
TREE
#652 TREE
#653 TREE
#654
TREE
#655
TREE
#618
TREE
#617
TREE
#626
TREE
#627
TREE
#625
TREE
#608
TREE
#605
TREE
#606
TREE
#597
TREE
#598
TREE
#559
LEGEND
EXISTING
TREES TO BE PROTECTED
TREE TO BE REMOVED AND
REQUIRED TO REPLACE
TREE TO BE REMOVED
TREE PROTECTION FENCE
REQUIRED TREES TO REPLACED
TREE TAG # TRUNK DIAMETER (IN) (QTY) PROPOSED
REPLACEMENT TREE
529 19 (1) 36"
532 18 (1) 36"
549 34 (2) 36"
548 31 (2) 36"
551 30 (2) 36"
550 35 (2) 36"
595 15 (1) 36"
602 12 (1) 36"
618 13 (1) 36"
635 13 (1) 36"
636 12 (1) 36"
644 12 (1) 36"
TOTAL (16) 36"
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
08.05. # REV
LA
23 Sa
41 KIFER DEVELOPMENT
1/16" =
TREE PROT
REMOVAL P
SHEET L100 SHEET L100
NOTE: ALL PROPOSED TREES ARE 36" BOX; PLEASE SEE
PLANTING PLAN SHEETS
1/32” = 1’-0”
TREE PROTECTION & REMOVAL PLAN 2 OF 2
SEE SHEET 1 OF 2 SEE SHEET 1 OF 2TREE #635
TREE
#637
TREE
#638
TREE
#639
TREE
#640
TREE
#641
TREE
#642
TREE
#644 TREE
#645
TREE
#647
TREE
#648
TREE #23
TREE #25
TREE #26
TREE #29
TREE #596
TREE #529
TREE #530
TREE #531 TREE #532
TREE #533
TREE
#634
TREE
#633
TREE
#632
TREE
#631
TREE
#630
TREE
#629
TREE
#628
TREE
#624
TREE
#623
TREE
#622
TREE
#621
TREE
#620
TREE
#614
TREE
#649
TREE
#650
TREE
#651
TREE
#599
TREE
#600
TREE
#601
TREE
#602
TREE
#603
TREE
#604
TREE
#607
TREE
#609
TREE
#610
TREE
#611
TREE
#612
TREE
#613
TREE
#614 TREE
#615
TREE
#616
TREE
#547
TREE
#546
TREE
#545
TREE
#524
TREE
#543
TREE
#544TREE
#541
TREE
#540
TREE
#538
TREE
#532
TREE
#536
TREE
#535
TREE
#534
TREE
#539
TREE
#548
TREE
#549
TREE
#551
TREE
#550
TREE
#552
TREE
#553
TREE
#554
TREE
#555
TREE
#556
TREE
#557
TREE
#558
#653 TREE
#654
TREE
#655
TREE
#618
TREE
#617
TREE
#626
TREE
#627
TREE
#625
TREE
#608
TREE
#605
TREE
#606
TREE
#597
TREE
#598
TREE
#559
LEGEND
EXISTING
TREES TO BE PROTECTED
TREE TO BE REMOVED AND
REQUIRED TO REPLACE
TREE TO BE REMOVED
TREE PROTECTION FENCE
REQUIRED TREES TO REPLACED
TREE TAG # TRUNK DIAMETER (IN) (QTY) PROPOSED
REPLACEMENT TREE
529 19 (1) 36"
532 18 (1) 36"
549 34 (2) 36"
548 31 (2) 36"
551 30 (2) 36"
550 35 (2) 36"
595 15 (1) 36"
602 12 (1) 36"
618 13 (1) 36"
635 13 (1) 36"
636 12 (1) 36"
644 12 (1) 36"
TOTAL (16) 36"
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
08.05. 2022
# REVISION
KIFER DEVELOPMENT
1/16" = 1'-0"
TREE PROTEC
REMOVAL PLA
NOTE: ALL PROPOSED TREES ARE 36" BOX; PLEASE SEE
PLANTING PLAN SHEETS
trees proposed for removal, the following guidelines shall apply (with exceptio ns considered for dead, unhealthy or hazardous trees or emergency situations):
Tree to be Removed Replacement Tree(s)
12” - 18” diameter
(36”-56” circumference)
One 24” box tree, or
Three 15-gallon trees
18” - 24” diameter
(56” -75” circumference)
One 36” box tree, or
Two 24” box trees
Over 24” diameter
(greater than 75” circumference)
One 48” box tree, or
Two 36” box trees, or
Four 24” box trees
If space permits, smaller size container trees are generally preferred over larger size boxed trees to maximize the quantity of replacement trees. Additionally, smaller size container trees usually adapt easier to soil conditions and over time may exceed the size of larger size boxed trees. However, if immediate screening or visual impac t is desired and sp ace is limited, larger boxed trees may be required. Where insufficient space is available to plant all or some of the required replacement trees or other site conditions or uses limit the feasibility of replacement trees, the following t ree replacement in -lieu fees shall be assessed.
Tree removal on properties without a Planning development application:
Replacement Tree Tree Replacement
In-Lieu Fee*
Each 24” box tree $441
Each 36” box tree $883
Each 48” box tree $1,765
* This fee does not include the tree removal permit fee.
PG 3 OF THE TREE REPLACEMENT REQUIREMENTS - HTTPS://WWW.SUNNYVALE.
CA.GOV/HOME/SHOWPUBLISHEDDOCUMENT/1420/637957155372030000 Attachment 6
54 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 37
LANDSCAPE SITE PLAN
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
TYP.
5-031-02
1-033-02
3-02
4-01
TYP.8-01 TYP.8-01
TYP.8-01
TYP.
8-01
EXISTING WALL STARTS HERE HEIGHT
OF PROPOSED WALLS TO MATCH
0 WORK BY OTHERS - FOR REFERENCE
SYMBOL DESCRIPTION NOTES
POOL AND SPA BY OTHERS
1 PAVEMENT, RAMPS, CURBS
SYMBOL DESCRIPTION NOTES
PAVING TYPE I SHARED-USE PATHWAY WITH PERMEABLE CONCRETE PAVING TYPE II C.I.P. PEDESTRIAN CONCRETE
PAVING TYPE III DECORATIVE CONCRETE
PAVING TYPE IV UNIT PAVER
PAVING TYPE V PERMEABLE UNIT PAVER
PAVING TYPE V VEHICULAR UNIT PAVERS
PAVING TYPE VI GRASSCRETE
PAVING TYPE VII ENTRY WALK PERFORATED METAL PAVING
0-01
1-01
1-02
1-03
1-04
1-05
1-06
1-07
1-08
MATERIALS NOTES SCHEDULE
2 STEPS
SYMBOL DESCRIPTION NOTES
STAIR TYPE I PERFORATED METAL STEPS
3 EDGING & WALLS
SYMBOL DESCRIPTION NOTES
EDGE TYPE I 6" - 10" WOOD OR CONCRETE CURB
WALL TYPE I 4'-0" RETAINING WALL
EDGE TYPE III 12" - 30" HIGH METAL EDGE
4 SITE FURNISHINGS
SYMBOL DESCRIPTION NOTES
BIKE RACK TYPE I LANDSCAPE FORMS - BOLA BIKE RACK - EMBEDDED BENCH TYPE I VESTRE BLOC BENCH WITH BACKREST 1516-900
BENCH TYPE II STREETLIFE ROUGH AND READY CUBE
BENCH TYPE III STREETLIFE ROUGH AND READY 6 BENCH
WASTE RECEPTACLES MMCITE CRYSTAL CS331 LITTER BIN
2-01
3-01
3-02
3-03
4-01
4-02
4-03
4-04
4-05
5 RAILINGS, BARRIERS, FENCING
SYMBOL DESCRIPTION NOTES
RAILING TYPE I 36" HIGH METAL HANDRAIL
FENCE TYPE I 6'-0" HIGH SLAT LOUVERED SCREEN FENCE WITH VINES BOLLARD TYPE I 27 1
2" TALL MMCITE LOT BOLLARD; REMOVABLE
8 PLANTING & LANDSCAPE
SYMBOL DESCRIPTION NOTES
PLANTING AREA SEE PLANTING PLAN
STORMWATER TYPE I STORMWATER BIORETENTION AREA
5-01
5-02
5-03
8-01
8-02
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 20
# REVIS
KIFER DEVELOPMENT
NOT FOR
1/16" = 1
MATERIALS
SHEET L201 SHEET L201
NOTE: FOR UTILITIES SEE CIVIL PLANS
1/32” = 1’-0”
MATERIALS PLAN 1 OF 2
SEE SHEET 2 OF 2 SEE SHEET 2 OF 2
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
DN
UP
UP
DN
DN
UP
UP
UP
3 -
1 -
2 -
4 -
5 6
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
TYP.
TYP.
TYP.
TYP.
TYP.
TYP. TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
1-01
1-06
1-07
2-011-08
8-01
8-02
4-01
5-01
5-02
4-02
4-03
4-04
1-02
1-02 1-02
1-02
1-02
1-02
1-01
1-04
1-07
1-08
2-01
4-05
1-02
4-01
8-02
3-03
3-03
1-05
1-05
1-05
1-05
EDGE OF PAVING IF
TREE DIES DURING
CONSTRUCTION
5-01
5-01
1-02
5-01
3-03
3-03 3-03 3-03
3-03 3-03 3-03 3-03 3-03
TYP.
3-03
1-04
TYP.
5-03
3-01 3-01
3-01
3-01
3-01
3-01
3-01
3-01
1-03
TYP.
NEW WAYFINDING SIGNAGE (TYPE
A) LOCATION PER PL-3 COMMENT
DELINEATED WALKWAY
MARKINGS
0 WORK BY OTHERS - FOR REFERENCE
SYMBOL DESCRIPTION NOTES
POOL AND SPA BY OTHERS
1 PAVEMENT, RAMPS, CURBS
SYMBOL DESCRIPTION NOTES
PAVING TYPE I SHARED-USE PATHWAY WITH PERMEABLE CONCRETE PAVING TYPE II C.I.P. PEDESTRIAN CONCRETE
PAVING TYPE III DECORATIVE CONCRETE
PAVING TYPE IV UNIT PAVER
PAVING TYPE V PERMEABLE UNIT PAVER
PAVING TYPE V VEHICULAR UNIT PAVERS
PAVING TYPE VI GRASSCRETE
PAVING TYPE VII ENTRY WALK PERFORATED METAL PAVING
0-01
1-01
1-02
1-03
1-04
1-05
1-06
1-07
1-08
MATERIALS NOTES SCHEDULE
2 STEPS
SYMBOL DESCRIPTION NOTES
STAIR TYPE I PERFORATED METAL STEPS
3 EDGING & WALLS
SYMBOL DESCRIPTION NOTES
EDGE TYPE I 6" - 10" WOOD OR CONCRETE CURB
WALL TYPE I 4'-0" RETAINING WALL
EDGE TYPE III 12" - 30" HIGH METAL EDGE
4 SITE FURNISHINGS
SYMBOL DESCRIPTION NOTES
BIKE RACK TYPE I LANDSCAPE FORMS - BOLA BIKE RACK - EMBEDDED BENCH TYPE I VESTRE BLOC BENCH WITH BACKREST 1516-900
BENCH TYPE II STREETLIFE ROUGH AND READY CUBE
BENCH TYPE III STREETLIFE ROUGH AND READY 6 BENCH
WASTE RECEPTACLES MMCITE CRYSTAL CS331 LITTER BIN
2-01
3-01
3-02
3-03
4-01
4-02
4-03
4-04
4-05
5 RAILINGS, BARRIERS, FENCING
SYMBOL DESCRIPTION NOTES
RAILING TYPE I 36" HIGH METAL HANDRAIL
FENCE TYPE I 6'-0" HIGH SLAT LOUVERED SCREEN FENCE WITH VINES BOLLARD TYPE I 27 1
2" TALL MMCITE LOT BOLLARD; REMOVABLE
8 PLANTING & LANDSCAPE
SYMBOL DESCRIPTION NOTES
PLANTING AREA SEE PLANTING PLAN
STORMWATER TYPE I STORMWATER BIORETENTION AREA
5-01
5-02
5-03
8-01
8-02
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx.
# RE
KIFER DEVELOPMENT
NOT F
1/16"
MATERIALS
NOTE: FOR UTILITIES SEE CIVIL PLANS
Attachment 6
55 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 37
LANDSCAPE SITE PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
DN
UP
UP
DN
DN
UP
UP
UP
3 -
1 -
2 -
4 -
5 6
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
TYP.
TYP.
TYP.
TYP.
TYP.
TYP. TYP.
TYP. TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
1-01
1-06
1-07
2-011-08
8-01
8-02
4-01
3-01
5-01
5-02
4-02
4-03
4-04
1-02
1-02 1-02
1-02
1-02
1-02
1-02
1-01
1-03
1-04
1-07
1-08
2-01
4-05
1-02
4-01
8-02
3-03
3-03
1-05
1-05
1-05
1-05
EDGE OF PAVING IF
TREE DIES DURING
CONSTRUCTION
5-01
5-01
1-02
5-01
3-03
3-03 3-03 3-03
3-03 3-03 3-03 3-03 3-03
TYP.
3-03
TYP.
3-01
1-04
TYP.
1-04
TYP.
5-03
3-01 3-01
3-01
3-01
3-01
3-01
3-01
3-01
3-01
1-03
3-01
TYP.
TYP.
NEW WAYFINDING SIGNAGE (TYPE
A) LOCATION PER PL-3 COMMENT
DELINEATED WALKWAY
MARKINGS
1-09
TYP.
0 WORK BY OTHERS - FOR REFERENCE
SYMBOL DESCRIPTION NOTES
POOL AND SPA BY OTHERS
1 PAVEMENT, RAMPS, CURBS
SYMBOL DESCRIPTION NOTES
PAVING TYPE I SHARED-USE PATHWAY WITH PERMEABLE CONCRETE PAVING TYPE II C.I.P. PEDESTRIAN CONCRETE
PAVING TYPE III DECORATIVE CONCRETE
PAVING TYPE IV UNIT PAVER
PAVING TYPE V PERMEABLE UNIT PAVER
PAVING TYPE V VEHICULAR UNIT PAVERS
PAVING TYPE VI GRASSCRETE
PAVING TYPE VII ENTRY WALK PERFORATED METAL PAVING
PAVING TYPE VIII STAMPED DECORATIVE ASPHALT IN RUNNING BOND PATTERN 0-01
1-01
1-02
1-03
1-04
1-05
1-06
1-07
1-08
1-09
MATERIALS NOTES SCHEDULE
2 STEPS
SYMBOL DESCRIPTION NOTES
STAIR TYPE I PERFORATED METAL STEPS
3 EDGING & WALLS
SYMBOL DESCRIPTION NOTES
EDGE TYPE I 6" - 10" WOOD OR CONCRETE CURB
WALL TYPE I 4`-0" RETAINING WALL
EDGE TYPE III 12" - 30" HIGH METAL EDGE
4 SITE FURNISHINGS
SYMBOL DESCRIPTION NOTES
BIKE RACK TYPE I LANDSCAPE FORMS - BOLA BIKE RACK - EMBEDDED BENCH TYPE I VESTRE BLOC BENCH WITH BACKREST 1516-900
BENCH TYPE II STREETLIFE ROUGH AND READY CUBE
BENCH TYPE III STREETLIFE ROUGH AND READY 6 BENCH
WASTE RECEPTACLES MMCITE CRYSTAL CS331 LITTER BIN
2-01
3-01
3-02
3-03
4-01
4-02
4-03
4-04
4-05
5 RAILINGS, BARRIERS, FENCING
SYMBOL DESCRIPTION NOTES
RAILING TYPE I 36" HIGH METAL HANDRAIL
FENCE TYPE I 6`-0" SLAT LOUVERED SCREEN FENCE WITH VINES BOLLARD TYPE I 27 1/2" TALL MMCITE LOT BOLLARD; REMOVABLE 8 PLANTING & LANDSCAPE
SYMBOL DESCRIPTION NOTES
PLANTING AREA SEE PLANTING PLAN
STORMWATER TYPE I STORMWATER BIORETENTION AREA
5-01
5-02
5-03
8-01
8-02
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
MATERIALS PLA
SHEET L200 SHEET L200
NOTE: FOR UTILITIES SEE CIVIL PLANS
1/32” = 1’-0”
MATERIALS PLAN 2 OF 2
SEE SHEET
1 OF 2
SEE SHEET
1 OF 2
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
DN
UP
UP
DN
DN
UP
UP
UP
3 -
1 -
2 -
4 -
5 6
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
TYP.
TYP.
TYP.
TYP.
TYP.
TYP. TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
1-01
1-06
1-07
2-011-08
8-01
8-02
4-01
5-01
5-02
4-02
4-03
4-04
1-02
1-02 1-02
1-02
1-02
1-02
1-01
1-04
1-07
1-08
2-01
4-05
1-02
4-01
8-02
3-03
3-03
1-05
1-05
1-05
1-05
EDGE OF PAVING IF
TREE DIES DURING
CONSTRUCTION
5-01
5-01
1-02
5-01
3-03
3-03 3-03 3-03
3-03 3-03 3-03 3-03 3-03
TYP.
3-03
1-04
TYP.
5-03
3-01 3-01
3-01
3-01
3-01
3-01
3-01
3-01
1-03
NEW WAYFINDING SIGNAGE (TYPE
A) LOCATION PER PL-3 COMMENT
DELINEATED WALKWAY
MARKINGS
0 WORK BY OTHERS - FOR REFERENCE
SYMBOL DESCRIPTION NOTES
POOL AND SPA BY OTHERS
1 PAVEMENT, RAMPS, CURBS
SYMBOL DESCRIPTION NOTES
PAVING TYPE I SHARED-USE PATHWAY WITH PERMEABLE CONCRETE PAVING TYPE II C.I.P. PEDESTRIAN CONCRETE
PAVING TYPE III DECORATIVE CONCRETE
PAVING TYPE IV UNIT PAVER
PAVING TYPE V PERMEABLE UNIT PAVER
PAVING TYPE V VEHICULAR UNIT PAVERS
PAVING TYPE VI GRASSCRETE
PAVING TYPE VII ENTRY WALK PERFORATED METAL PAVING
PAVING TYPE VIII STAMPED DECORATIVE ASPHALT IN RUNNING BOND PATTERN 0-01
1-01
1-02
1-03
1-04
1-05
1-06
1-07
1-08
1-09
MATERIALS NOTES SCHEDULE
2 STEPS
SYMBOL DESCRIPTION NOTES
STAIR TYPE I PERFORATED METAL STEPS
3 EDGING & WALLS
SYMBOL DESCRIPTION NOTES
EDGE TYPE I 6" - 10" WOOD OR CONCRETE CURB
WALL TYPE I 4`-0" RETAINING WALL
EDGE TYPE III 12" - 30" HIGH METAL EDGE
4 SITE FURNISHINGS
SYMBOL DESCRIPTION NOTES
BIKE RACK TYPE I LANDSCAPE FORMS - BOLA BIKE RACK - EMBEDDED BENCH TYPE I VESTRE BLOC BENCH WITH BACKREST 1516-900
BENCH TYPE II STREETLIFE ROUGH AND READY CUBE
BENCH TYPE III STREETLIFE ROUGH AND READY 6 BENCH
WASTE RECEPTACLES MMCITE CRYSTAL CS331 LITTER BIN
2-01
3-01
3-02
3-03
4-01
4-02
4-03
4-04
4-05
5 RAILINGS, BARRIERS, FENCING
SYMBOL DESCRIPTION NOTES
RAILING TYPE I 36" HIGH METAL HANDRAIL
FENCE TYPE I 6`-0" SLAT LOUVERED SCREEN FENCE WITH VINES BOLLARD TYPE I 27 1/2" TALL MMCITE LOT BOLLARD; REMOVABLE 8 PLANTING & LANDSCAPE
SYMBOL DESCRIPTION NOTES
PLANTING AREA SEE PLANTING PLAN
STORMWATER TYPE I STORMWATER BIORETENTION AREA
5-01
5-02
5-03
8-01
8-02
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx.
# RE
KIFER DEVELOPMENT
NOT F
1/16"
MATERIALS
NOTE: FOR UTILITIES SEE CIVIL PLANS
I
Attachment 6
56 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 38
LANDSCAPE PLAN LEVEL 4
2 A300
1 A300
1 A400
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
TYP.
TYP.
TYP. TYP.
TYP.
1-10 1-10
1-11
1-11
1-11
8-03
8-03
4-06
4-07
4-08
4-08
4-08
4-09
0-01
8-04 TYP.
4-10TYP.
4-08 TYP.
4-11
4-11
0 WORK BY OTHERS - FOR REFERENCE
SYMBOL DESCRIPTION NOTES
POOL AND SPA BY OTHERS
1 PAVEMENT, RAMPS, CURBS
SYMBOL DESCRIPTION NOTES
PAVING TYPE IX PEDESTAL UNIT PAVERS
PAVING TYPE X PEDESTAL WOOD DECKING
4 SITE FURNISHINGS
SYMBOL DESCRIPTION NOTES
BBQ GRILL TYPE I BBQ GRILL
FIRE FEATURE TYPE I FIRE FEATURE
MOVEABLE FURNITURE PROVIDED BY CLIENT
EXERCISE EQUIPMENT PROVIDED BY CLIENT
TABLE TYPE I 30" - 42" HIGH LAPTOP WOOD TABLE
BUILT-IN FURNITURE WOOD BUILT-IN BENCH
8 PLANTING & LANDSCAPE
SYMBOL DESCRIPTION NOTES
PLANTING TYPE I RAISED PLANTER
PLANTING TYPE II PLANTING POT
0-01
1-10
1-11
4-06
4-07
4-08
4-09
4-10
4-11
8-03
8-04
MATERIALS NOTES SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
# REVISION L
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
MATERIALS PLA1/32” = 1’-0”
MATERIALS PLAN
2 A300
1 A300
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
TYP.
TYP.
TYP. TYP.
TYP.
1-10 1-10
1-11
1-11
1-11
8-03
8-03
4-06
4-07
4-08
4-08
4-08
4-09
0-01
8-04 TYP.
4-10TYP.
4-08 TYP.
4-11
4-11
0 WORK BY OTHERS - FOR REFERENCE
SYMBOL DESCRIPTION NOTES
POOL AND SPA BY OTHERS
1 PAVEMENT, RAMPS, CURBS
SYMBOL DESCRIPTION NOTES
PAVING TYPE IX PEDESTAL UNIT PAVERS
PAVING TYPE X PEDESTAL WOOD DECKING
4 SITE FURNISHINGS
SYMBOL DESCRIPTION NOTES
BBQ GRILL TYPE I BBQ GRILL
FIRE FEATURE TYPE I FIRE FEATURE
MOVEABLE FURNITURE PROVIDED BY CLIENT
EXERCISE EQUIPMENT PROVIDED BY CLIENT
TABLE TYPE I 30" - 42" HIGH LAPTOP WOOD TABLE
BUILT-IN FURNITURE WOOD BUILT-IN BENCH
8 PLANTING & LANDSCAPE
SYMBOL DESCRIPTION NOTES
PLANTING TYPE I RAISED PLANTER
PLANTING TYPE II PLANTING POT
0-01
1-10
1-11
4-06
4-07
4-08
4-09
4-10
4-11
8-03
8-04
MATERIALS NOTES SCHEDULE
S
S
I
P
D
S
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch K
M
Attachment 6
57 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 39
LANDSCAPE PLAN LEVEL 8
2 A300
1 A300
1 A400
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
8-03 8-03
TYP.
4-08
1-10
1-11
8-03
4-08
TYP.
TYP.
4-08
1-10
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
4-10 TYP.
4-10
TYP.
8-04 TYP.
4-10 TYP.
8-04 TYP.
1 PAVEMENT, RAMPS, CURBS
SYMBOL DESCRIPTION DETAIL NOTES
PAVING TYPE IX PEDESTAL UNIT PAVERS
PAVING TYPE X PEDESTAL WOOD DECKING
4 SITE FURNISHINGS
SYMBOL DESCRIPTION DETAIL DETAIL
MOVEABLE
FURNITURE
TABLE TYPE I 30" - 42" HIGH LAPTOP WOOD TABLE
8 PLANTING & LANDSCAPE
SYMBOL DESCRIPTION DETAIL NOTES
PLANTING TYPE I RAISED PLANTER
PLANTING TYPE II PLANTING POT
1-10
1-11
4-08
4-10
8-03
8-04
MATERIALS NOTES SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
MATERIALS PLA
SHEET L202 SHEET L202
1/32” = 1’-0”
MATERIALS PLAN
2 A300
1 A300
A400
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
8-03 8-03
TYP.
4-08
1-10
1-11
8-03
4-08
TYP.
TYP.
4-08
1-10
TYP.
TYP.
TYP.
TYP.
TYP.
TYP.
4-10 TYP.
4-10
TYP.
8-04 TYP.
4-10 TYP.
8-04 TYP.
1 PAVEMENT, RAMPS, CURBS
SYMBOL DESCRIPTION DETAIL NOTES
PAVING TYPE IX PEDESTAL UNIT PAVERS
PAVING TYPE X PEDESTAL WOOD DECKING
4 SITE FURNISHINGS
SYMBOL DESCRIPTION DETAIL DETAIL
MOVEABLE
FURNITURE
TABLE TYPE I 30" - 42" HIGH LAPTOP WOOD TABLE
8 PLANTING & LANDSCAPE
SYMBOL DESCRIPTION DETAIL NOTES
PLANTING TYPE I RAISED PLANTER
PLANTING TYPE II PLANTING POT
1-10
1-11
4-08
4-10
8-03
8-04
MATERIALS NOTES SCHEDULE
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch Attachment 6
58 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
42 LANDSCAPE - SITE FURNISHING
MMCite Crystal Litter BinLandscape Forms Bola Bike Rack Vestre Bloc Bench with Backrest
PRODUCT IMAGES & TYPICAL BIKE LAYOUT
Streetlife Rough and Ready CubeStreetlife Rough and Ready 6 BenchMMCite Lot Bollard SCALE:
0 1' 2' 4'
BOLA BIKE RACK - LAYOUT
TYPICAL SECTION
1/2"=1'-0"
3'-0"
2'-4" 3'-0" MIN.
2'-0"
BOLA BIKE RACKBIKE, TYP.
SCALE:
0 1' 2' 4'
BOLA BIKE RACK - ELEVATION
TYPICAL SECTION
1/2"=1'-0"
2'-8 1/8"
2'-4"
6"
GRADE
1 1/2"
15°
N
"
SCALE:
0 1' 2' 4'
BOLA BIKE RACK - ELEVATION
TYPICAL SECTION
1/2"=1'-0"
2'-8 1/8"
2'-4"
6"
GRADE
1 1/2"
15°
Attachment 6
59 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE - SITE SURFACES
PRODUCT IMAGES
1-01 Shared-Use Pathway - Permeable Concrete 1-02 C.I.P. Pedestrian Concrete 1-03 Decorative Concrete 1-04 Unit Paver 1-05 Permeable Unit Paver 1-06 Vehicular Unit Paver 1-07 Grasscrete 1-08 Perforated Metal 1-09 Pedestal Unit 1-10 Pedestal Wood Decking
1-10 Decorative Stamped Asphalt
Attachment 6
60 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 37
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 20
# REVIS
KIFER DEVELOPMENT
NOT FOR
1/16" = 1
IRRIGATION
SHEET L501 SHEET L501
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
CALL BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
NOTES:
1. IRRIGATION EQUIPMENT MAY BE SHOWN WITHIN HARDSCAPE FOR GRAPHIC CLARITY ONLY.
INSTALL ALL IRRIGATION EQUIPMENT WITHIN PLANTED AREAS. IRRIGATION PIPE AND WIRE
CROSSING BENEATH HARDSCAPE SURFACES SHALL BE CONTAINED WITHIN SLEEVING OR SCHEDULE 40 PVC CONDUIT. SLEEVING SIZE SHALL BE A MINIMUM OF TWO TIMES THE AGGREGATE DIAMETER OF ALL PIPES CONTAINED WITH SLEEVE. PROVIDE VERTICAL SWEEP FOR ALL ELECTRICAL CONDUIT ON EACH SIDE OF HARDSCAPE AND TERMINATE ENDS AT 12" MINIMUM DEPTH AND 12" FROM HARDSCAPE SURFACE.
2. UNSIZED LATERAL LINE PIPING LOCATED DOWN STREAM OF 1" PIPING SHALL BE 3/4" IN SIZE (TYPICAL).
3. SIZING OF LATERAL PIPE SHALL BE AS FOLLOWS:
0.75" 0-6 GPM
1" 7-12 GPM
1.25" 13-20 GPM
4. SIZING OF LATERAL PIPE FOR DRIPLINE (12" O.C. GRID WITH 0.6 GPH OR LESS EMITTERS) SHALL BE AS FOLLOWS:
0.75 0-500 FT
1" 501-1100 FT
1.25" 1101-2000 FT
1.5" 2001-3000 FT
5. EACH DRIP ZONE SHALL RECEIVE A SET OF AIR VENT/VACUUM RELIEF VALVE AT THE HIGHS POINT AND FLUSH VALVES AT FARTHEST ENDS OF EACH SYSTEM AND EACH PLANTER.
6. CONTRACTOR TO INSTALL ALL IRRIGATION PIPING TO GO AROUND ALL UTILITY BOX, LIGHTS, SIGNS, ETC. (DRAWINGS ARE DIAGRAMMATIC).
7. FOR GRAPHIC CLARITY MAINLINE, REMOTE CONTROL VALVE AND LATERAL IS SHOWN OUTSIDE PLANTER. MAINLINE, REMOTE CONTROL VALVE AND LATERAL SHALL BE LOCATED WITHIN PLANTING AREAS. (TYPICAL)
1/32” = 1’-0”
SITE PLAN 1 OF 2 - L500
SEE SHEET 2 OF 2 SEE SHEET 2 OF 2
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
# REVISION LIST
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCT
L
1/16" = 1'-0"
IRRIGATION PLAN
SHEET L501 SHEET L501
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
CALL BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
NOTES:
1. IRRIGATION EQUIPMENT MAY BE SHOWN WITHIN HARDSCAPE FOR GRAPHIC CLARITY ONLY.
INSTALL ALL IRRIGATION EQUIPMENT WITHIN PLANTED AREAS. IRRIGATION PIPE AND WIRE
CROSSING BENEATH HARDSCAPE SURFACES SHALL BE CONTAINED WITHIN SLEEVING OR SCHEDULE 40 PVC CONDUIT. SLEEVING SIZE SHALL BE A MINIMUM OF TWO TIMES THE AGGREGATE DIAMETER OF ALL PIPES CONTAINED WITH SLEEVE. PROVIDE VERTICAL SWEEP FOR ALL ELECTRICAL CONDUIT ON EACH SIDE OF HARDSCAPE AND TERMINATE ENDS AT 12" MINIMUM DEPTH AND 12" FROM HARDSCAPE SURFACE.
2. UNSIZED LATERAL LINE PIPING LOCATED DOWN STREAM OF 1" PIPING SHALL BE 3/4" IN SIZE (TYPICAL).
3. SIZING OF LATERAL PIPE SHALL BE AS FOLLOWS:
0.75" 0-6 GPM
1" 7-12 GPM
1.25" 13-20 GPM
4. SIZING OF LATERAL PIPE FOR DRIPLINE (12" O.C. GRID WITH 0.6 GPH OR LESS EMITTERS) SHALL BE AS FOLLOWS:
0.75 0-500 FT
1" 501-1100 FT
1.25" 1101-2000 FT
1.5" 2001-3000 FT
5. EACH DRIP ZONE SHALL RECEIVE A SET OF AIR VENT/VACUUM RELIEF VALVE AT THE HIGHS POINT AND FLUSH VALVES AT FARTHEST ENDS OF EACH SYSTEM AND EACH PLANTER.
6. CONTRACTOR TO INSTALL ALL IRRIGATION PIPING TO GO AROUND ALL UTILITY BOX, LIGHTS, SIGNS, ETC. (DRAWINGS ARE DIAGRAMMATIC).
7. FOR GRAPHIC CLARITY MAINLINE, REMOTE CONTROL VALVE AND LATERAL IS SHOWN OUTSIDE PLANTER. MAINLINE, REMOTE CONTROL VALVE AND LATERAL SHALL BE LOCATED WITHIN PLANTING AREAS. (TYPICAL)
SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 9
2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
7 DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
LANDSCAPE - IRRIGATION
15'-0"
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
MVFSEZ
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2
# REV
AN
LA
23 Sa
41 KIFER DEVELOPMENT
NOT FO
1/16" =
IRRIGATION
SHEET L600 SHEET L600
POINT OF CONNECTION TO POTABLE WATER METER .
1.5" WATER METER WITH 2" SERVICE LINE FOR IRRIGATION MAXIMUM IRRIGATION DEMAND: 20 GPM AT A MINIMUM 65 PSI STATIC PRESSURE AT WATER METER LOCATION. CONTRACTOR TO FIELD VERIFIED THE PRESSURE BEFORE COMMENCING THE WORK. (IF THE PRESSURE AS NOTED IS NOT
ACCURATE A BOOSTER PUMP SHALL BE REQUIRED FOR THE SYSTEM TO FUNCTION PROPERLY).
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
CALL BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1" CONDUIT ROUTED THROUGH BUILDING TO 4TH LEVEL PLANTER, WITH PULL
ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE THE VALVES. (REFER TO SHEET L5.02)
2 SHEET NOTES:
1 IRRIGATION COORDINATION NOTES
1. PEX PIPING WITHIN STRUCTURE SHALL BE PROVIDED,
ROUTED AND INSTALLED BY PLUMBING CONTRACTOR.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND
PULL BOXES IN STRUCTURE. INSTALLATION OF WIRING TO
REMOTE CONTROL VALVES AND CONTROLLER SHALL BE
COMPLETED BY IRRIGATION CONTRACTOR.
1" CONDUIT ROUTED THROUGH BUILDING TO 8TH LEVEL PLANTER, WITH
PULL ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK. (REFER TO SHEET L5.03)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING TO 8TH LEVEL
PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR.
(REFER TO SHEET L5.03)
4 3
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING TO 4TH LEVEL
PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.02)
IRRIGATION CONTROLLER "C".
MOUNT ON WALL AT THIS LOCATION AS DETAILED. CONNECT TO 120 VOLT A.C.
ELECTRICAL SERVICE INSTALLED AT THIS LOCATION UNDER ELECTRICAL CONTRACT. IRRIGATION CONTRACTOR SHALL COORDINATE LOCATION OF ELECTRICAL SERVICE PRIOR TO CONSTRUCTION. (COORDINATE WITH GENERAL CONTRACTOR FOR FINAL LOCATION)-(2-WIRE CONTROLLER).
ELECTRICAL CONTRACTOR TO INSTALL 1" CONDUIT WITH PULL CORD FOR LOW VOLTAGE WIRES.
NOTES:
1. IRRIGATION EQUIPMENT MAY BE SHOWN WITHIN HARDSCAPE FOR GRAPHIC CLARITY ONLY. INSTALL ALL IRRIGATION EQUIPMENT WITHIN PLANTED AREAS. IRRIGATION PIPE
AND WIRE CROSSING BENEATH HARDSCAPE SURFACES SHALL BE CONTAINED WITHIN SLEEVING OR SCHEDULE 40 PVC CONDUIT. SLEEVING SIZE SHALL BE A MINIMUM OF TWO TIMES THE AGGREGATE DIAMETER OF ALL PIPES CONTAINED WITH SLEEVE. PROVIDE
VERTICAL SWEEP FOR ALL ELECTRICAL CONDUIT ON EACH SIDE OF HARDSCAPE AND TERMINATE ENDS AT 12" MINIMUM DEPTH AND 12" FROM HARDSCAPE SURFACE.
2. UNSIZED LATERAL LINE PIPING LOCATED DOWN STREAM OF 1" PIPING SHALL BE 3/4" IN SIZE (TYPICAL).
3. SIZING OF LATERAL PIPE SHALL BE AS FOLLOWS:
0.75" 0-6 GPM
1" 7-12 GPM
1.25" 13-20 GPM
4. SIZING OF LATERAL PIPE FOR DRIPLINE (12" O.C. GRID WITH 0.6 GPH OR LESS EMITTERS) SHALL BE AS FOLLOWS:
0.75 0-500 FT
1" 501-1100 FT
1.25" 1101-2000 FT
1.5" 2001-3000 FT
5. EACH DRIP ZONE SHALL RECEIVE A SET OF AIR VENT/VACUUM RELIEF VALVE AT THE
HIGHS POINT AND FLUSH VALVES AT FARTHEST ENDS OF EACH SYSTEM AND EACH PLANTER.
6. CONTRACTOR TO INSTALL ALL IRRIGATION PIPING TO GO AROUND ALL UTILITY BOX, LIGHTS, SIGNS, ETC. (DRAWINGS ARE DIAGRAMMATIC).
7. FOR GRAPHIC CLARITY MAINLINE, REMOTE CONTROL VALVE AND LATERAL IS SHOWN OUTSIDE PLANTER. MAINLINE, REMOTE CONTROL VALVE AND LATERAL SHALL BE LOCATED WITHIN PLANTING AREAS. (TYPICAL)
WIRELESS WEATHER SENSOR AND RAIN SENSOR. MOUNT ON EVE OF BUILDING. INSTALL SENSOR OPEN TO THE SKY. COORDINATE AND CONFIRM EXACT LOCATION WITH OWNER'S REPRESENTATIVE.
REFER TO IRRIGATION LEGEND.
NEW REDUCED PRESSURE BACKFLOW ASSEMBLY WITH VIT STRONGBOX ENCLOSURE AND FREEZE BLANKET. REFER TO IRRIGATION LEGEND.
FLOW SENSOR.
REFER TO THE IRRIGATION LEGEND.
BRASS MASTER CONTROL VALVE
(LINE SIZE) REFER TO THE IRRIGATION LEGEND.
5 6
7 8
9 10
EZ-FLOW FERTILIZING SYSTEM WITH A 2" MAIN LINE CONNECTOR WITH BALL VALVE. CONTACT PHIL VANGENE WITH ANY QUESTION
CELL: 925-250-5885 EMAIL: [email protected]
11 SHEET L600
1 2
1 2
3 4
5 6
78 9
10 11
EXISTING PLANTING
AREA ZONE
Attachment 6
61 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 37
LANDSCAPE - IRRIGATION
15'-0"
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
MVFSEZ
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
IRRIGATION PL
POINT OF CONNECTION TO POTABLE WATER METER .
1.5" WATER METER WITH 2" SERVICE LINE FOR IRRIGATION MAXIMUM IRRIGATION DEMAND: 20 GPM AT A MINIMUM 65 PSI STATIC PRESSURE AT WATER METER LOCATION. CONTRACTOR TO FIELD VERIFIED THE PRESSURE BEFORE COMMENCING THE WORK. (IF THE PRESSURE AS NOTED IS NOT
ACCURATE A BOOSTER PUMP SHALL BE REQUIRED FOR THE SYSTEM TO FUNCTION PROPERLY).
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
CALL BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1" CONDUIT ROUTED THROUGH BUILDING TO 4TH LEVEL PLANTER, WITH PULL
ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE THE VALVES. (REFER TO SHEET L5.02)
2 SHEET NOTES:
1 IRRIGATION COORDINATION NOTES
1. PEX PIPING WITHIN STRUCTURE SHALL BE PROVIDED,
ROUTED AND INSTALLED BY PLUMBING CONTRACTOR.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND
PULL BOXES IN STRUCTURE. INSTALLATION OF WIRING TO
REMOTE CONTROL VALVES AND CONTROLLER SHALL BE
COMPLETED BY IRRIGATION CONTRACTOR.
1" CONDUIT ROUTED THROUGH BUILDING TO 8TH LEVEL PLANTER, WITH
PULL ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK. (REFER TO SHEET L5.03)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING TO 8TH LEVEL
PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR.
(REFER TO SHEET L5.03)
4 3
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING TO 4TH LEVEL
PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.02)
IRRIGATION CONTROLLER "C".
MOUNT ON WALL AT THIS LOCATION AS DETAILED. CONNECT TO 120 VOLT A.C.
ELECTRICAL SERVICE INSTALLED AT THIS LOCATION UNDER ELECTRICAL CONTRACT. IRRIGATION CONTRACTOR SHALL COORDINATE LOCATION OF ELECTRICAL SERVICE PRIOR TO CONSTRUCTION. (COORDINATE WITH GENERAL CONTRACTOR FOR FINAL LOCATION)-(2-WIRE CONTROLLER).
ELECTRICAL CONTRACTOR TO INSTALL 1" CONDUIT WITH PULL CORD FOR LOW VOLTAGE WIRES.
NOTES:
1. IRRIGATION EQUIPMENT MAY BE SHOWN WITHIN HARDSCAPE FOR GRAPHIC CLARITY ONLY. INSTALL ALL IRRIGATION EQUIPMENT WITHIN PLANTED AREAS. IRRIGATION PIPE
AND WIRE CROSSING BENEATH HARDSCAPE SURFACES SHALL BE CONTAINED WITHIN SLEEVING OR SCHEDULE 40 PVC CONDUIT. SLEEVING SIZE SHALL BE A MINIMUM OF TWO TIMES THE AGGREGATE DIAMETER OF ALL PIPES CONTAINED WITH SLEEVE. PROVIDE
VERTICAL SWEEP FOR ALL ELECTRICAL CONDUIT ON EACH SIDE OF HARDSCAPE AND TERMINATE ENDS AT 12" MINIMUM DEPTH AND 12" FROM HARDSCAPE SURFACE.
2. UNSIZED LATERAL LINE PIPING LOCATED DOWN STREAM OF 1" PIPING SHALL BE 3/4" IN SIZE (TYPICAL).
3. SIZING OF LATERAL PIPE SHALL BE AS FOLLOWS:
0.75" 0-6 GPM
1" 7-12 GPM
1.25" 13-20 GPM
4. SIZING OF LATERAL PIPE FOR DRIPLINE (12" O.C. GRID WITH 0.6 GPH OR LESS EMITTERS) SHALL BE AS FOLLOWS:
0.75 0-500 FT
1" 501-1100 FT
1.25" 1101-2000 FT
1.5" 2001-3000 FT
5. EACH DRIP ZONE SHALL RECEIVE A SET OF AIR VENT/VACUUM RELIEF VALVE AT THE
HIGHS POINT AND FLUSH VALVES AT FARTHEST ENDS OF EACH SYSTEM AND EACH PLANTER.
6. CONTRACTOR TO INSTALL ALL IRRIGATION PIPING TO GO AROUND ALL UTILITY BOX, LIGHTS, SIGNS, ETC. (DRAWINGS ARE DIAGRAMMATIC).
7. FOR GRAPHIC CLARITY MAINLINE, REMOTE CONTROL VALVE AND LATERAL IS SHOWN OUTSIDE PLANTER. MAINLINE, REMOTE CONTROL VALVE AND LATERAL SHALL BE WIRELESS WEATHER SENSOR AND RAIN SENSOR. MOUNT ON EVE OF BUILDING. INSTALL SENSOR OPEN TO THE SKY. COORDINATE AND CONFIRM EXACT LOCATION WITH OWNER'S REPRESENTATIVE.
REFER TO IRRIGATION LEGEND.
NEW REDUCED PRESSURE BACKFLOW ASSEMBLY WITH VIT STRONGBOX ENCLOSURE AND FREEZE BLANKET. REFER TO IRRIGATION LEGEND.
FLOW SENSOR.
REFER TO THE IRRIGATION LEGEND.
BRASS MASTER CONTROL VALVE
(LINE SIZE) REFER TO THE IRRIGATION LEGEND.
5 6
7 8
9 10
EZ-FLOW FERTILIZING SYSTEM WITH A 2" MAIN LINE CONNECTOR WITH BALL VALVE. CONTACT PHIL VANGENE WITH ANY QUESTION
CELL: 925-250-5885 EMAIL: [email protected]
11 1
2 1
2 3
4 5
6 78
9 10
11 1/32” = 1’-0”
SITE PLAN 2 OF 2 - L501
SEE SHEET
1 OF 2
SEE SHEET
1 OF 2
15'-0"
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
MVFSEZ
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L501
1/16" = 1'-0"
IRRIGATION PLAN
POINT OF CONNECTION TO POTABLE WATER METER .
1.5" WATER METER WITH 2" SERVICE LINE FOR IRRIGATION MAXIMUM IRRIGATION DEMAND: 20 GPM AT A MINIMUM 65 PSI STATIC PRESSURE AT WATER METER LOCATION. CONTRACTOR TO FIELD VERIFIED THE PRESSURE BEFORE COMMENCING THE WORK. (IF THE PRESSURE AS NOTED IS NOT
ACCURATE A BOOSTER PUMP SHALL BE REQUIRED FOR THE SYSTEM TO FUNCTION PROPERLY).
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
CALL BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1" CONDUIT ROUTED THROUGH BUILDING TO 4TH LEVEL PLANTER, WITH PULL
ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE THE VALVES. (REFER TO SHEET L5.02)
2 SHEET NOTES:
1 IRRIGATION COORDINATION NOTES
1. PEX PIPING WITHIN STRUCTURE SHALL BE PROVIDED,
ROUTED AND INSTALLED BY PLUMBING CONTRACTOR.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND
PULL BOXES IN STRUCTURE. INSTALLATION OF WIRING TO
REMOTE CONTROL VALVES AND CONTROLLER SHALL BE
COMPLETED BY IRRIGATION CONTRACTOR.
1" CONDUIT ROUTED THROUGH BUILDING TO 8TH LEVEL PLANTER, WITH
PULL ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK. (REFER TO SHEET L5.03)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING TO 8TH LEVEL
PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR.
(REFER TO SHEET L5.03)
4 3
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING TO 4TH LEVEL
PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.02)
IRRIGATION CONTROLLER "C".
MOUNT ON WALL AT THIS LOCATION AS DETAILED. CONNECT TO 120 VOLT A.C.
ELECTRICAL SERVICE INSTALLED AT THIS LOCATION UNDER ELECTRICAL CONTRACT. IRRIGATION CONTRACTOR SHALL COORDINATE LOCATION OF ELECTRICAL SERVICE PRIOR TO CONSTRUCTION. (COORDINATE WITH GENERAL CONTRACTOR FOR FINAL LOCATION)-(2-WIRE CONTROLLER).
ELECTRICAL CONTRACTOR TO INSTALL 1" CONDUIT WITH PULL CORD FOR LOW VOLTAGE WIRES.
NOTES:
1. IRRIGATION EQUIPMENT MAY BE SHOWN WITHIN HARDSCAPE FOR GRAPHIC CLARITY ONLY. INSTALL ALL IRRIGATION EQUIPMENT WITHIN PLANTED AREAS. IRRIGATION PIPE
AND WIRE CROSSING BENEATH HARDSCAPE SURFACES SHALL BE CONTAINED WITHIN SLEEVING OR SCHEDULE 40 PVC CONDUIT. SLEEVING SIZE SHALL BE A MINIMUM OF TWO TIMES THE AGGREGATE DIAMETER OF ALL PIPES CONTAINED WITH SLEEVE. PROVIDE
VERTICAL SWEEP FOR ALL ELECTRICAL CONDUIT ON EACH SIDE OF HARDSCAPE AND TERMINATE ENDS AT 12" MINIMUM DEPTH AND 12" FROM HARDSCAPE SURFACE.
2. UNSIZED LATERAL LINE PIPING LOCATED DOWN STREAM OF 1" PIPING SHALL BE 3/4" IN SIZE (TYPICAL).
3. SIZING OF LATERAL PIPE SHALL BE AS FOLLOWS:
0.75" 0-6 GPM
1" 7-12 GPM
1.25" 13-20 GPM
4. SIZING OF LATERAL PIPE FOR DRIPLINE (12" O.C. GRID WITH 0.6 GPH OR LESS EMITTERS) SHALL BE AS FOLLOWS:
0.75 0-500 FT
1" 501-1100 FT
1.25" 1101-2000 FT
1.5" 2001-3000 FT
5. EACH DRIP ZONE SHALL RECEIVE A SET OF AIR VENT/VACUUM RELIEF VALVE AT THE
HIGHS POINT AND FLUSH VALVES AT FARTHEST ENDS OF EACH SYSTEM AND EACH PLANTER.
6. CONTRACTOR TO INSTALL ALL IRRIGATION PIPING TO GO AROUND ALL UTILITY BOX, LIGHTS, SIGNS, ETC. (DRAWINGS ARE DIAGRAMMATIC).
7. FOR GRAPHIC CLARITY MAINLINE, REMOTE CONTROL VALVE AND LATERAL IS SHOWN OUTSIDE PLANTER. MAINLINE, REMOTE CONTROL VALVE AND LATERAL SHALL BE LOCATED WITHIN PLANTING AREAS. (TYPICAL)
WIRELESS WEATHER SENSOR AND RAIN SENSOR. MOUNT ON EVE OF BUILDING. INSTALL SENSOR OPEN TO THE SKY. COORDINATE AND CONFIRM EXACT LOCATION WITH OWNER'S REPRESENTATIVE.
REFER TO IRRIGATION LEGEND.
NEW REDUCED PRESSURE BACKFLOW ASSEMBLY WITH VIT STRONGBOX ENCLOSURE AND FREEZE BLANKET. REFER TO IRRIGATION LEGEND.
FLOW SENSOR.
REFER TO THE IRRIGATION LEGEND.
BRASS MASTER CONTROL VALVE
(LINE SIZE) REFER TO THE IRRIGATION LEGEND.
5 6
7 8
9 10
EZ-FLOW FERTILIZING SYSTEM WITH A 2" MAIN LINE CONNECTOR WITH BALL VALVE. CONTACT PHIL VANGENE WITH ANY QUESTION
CELL: 925-250-5885 EMAIL: [email protected]
11 1
2 1
2 3
4 5
6 78
9 10
11 15'-0"
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
MVFSEZ
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L501
1/16" = 1'-0"
IRRIGATION PLAN
POINT OF CONNECTION TO POTABLE WATER METER .
1.5" WATER METER WITH 2" SERVICE LINE FOR IRRIGATION MAXIMUM IRRIGATION DEMAND: 20 GPM AT A MINIMUM 65 PSI STATIC PRESSURE AT WATER METER LOCATION. CONTRACTOR TO FIELD VERIFIED THE PRESSURE BEFORE COMMENCING THE WORK. (IF THE PRESSURE AS NOTED IS NOT
ACCURATE A BOOSTER PUMP SHALL BE REQUIRED FOR THE SYSTEM TO FUNCTION PROPERLY).
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
CALL BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1" CONDUIT ROUTED THROUGH BUILDING TO 4TH LEVEL PLANTER, WITH PULL
ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE THE VALVES. (REFER TO SHEET L5.02)
2 SHEET NOTES:
1 IRRIGATION COORDINATION NOTES
1. PEX PIPING WITHIN STRUCTURE SHALL BE PROVIDED,
ROUTED AND INSTALLED BY PLUMBING CONTRACTOR.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND
PULL BOXES IN STRUCTURE. INSTALLATION OF WIRING TO
REMOTE CONTROL VALVES AND CONTROLLER SHALL BE
COMPLETED BY IRRIGATION CONTRACTOR.
1" CONDUIT ROUTED THROUGH BUILDING TO 8TH LEVEL PLANTER, WITH
PULL ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK. (REFER TO SHEET L5.03)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING TO 8TH LEVEL
PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR.
(REFER TO SHEET L5.03)
4 3
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING TO 4TH LEVEL
PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.02)
IRRIGATION CONTROLLER "C".
MOUNT ON WALL AT THIS LOCATION AS DETAILED. CONNECT TO 120 VOLT A.C.
ELECTRICAL SERVICE INSTALLED AT THIS LOCATION UNDER ELECTRICAL CONTRACT. IRRIGATION CONTRACTOR SHALL COORDINATE LOCATION OF ELECTRICAL SERVICE PRIOR TO CONSTRUCTION. (COORDINATE WITH GENERAL CONTRACTOR FOR FINAL LOCATION)-(2-WIRE CONTROLLER).
ELECTRICAL CONTRACTOR TO INSTALL 1" CONDUIT WITH PULL CORD FOR LOW VOLTAGE WIRES.
NOTES:
1. IRRIGATION EQUIPMENT MAY BE SHOWN WITHIN HARDSCAPE FOR GRAPHIC CLARITY ONLY. INSTALL ALL IRRIGATION EQUIPMENT WITHIN PLANTED AREAS. IRRIGATION PIPE
AND WIRE CROSSING BENEATH HARDSCAPE SURFACES SHALL BE CONTAINED WITHIN SLEEVING OR SCHEDULE 40 PVC CONDUIT. SLEEVING SIZE SHALL BE A MINIMUM OF TWO TIMES THE AGGREGATE DIAMETER OF ALL PIPES CONTAINED WITH SLEEVE. PROVIDE
VERTICAL SWEEP FOR ALL ELECTRICAL CONDUIT ON EACH SIDE OF HARDSCAPE AND TERMINATE ENDS AT 12" MINIMUM DEPTH AND 12" FROM HARDSCAPE SURFACE.
2. UNSIZED LATERAL LINE PIPING LOCATED DOWN STREAM OF 1" PIPING SHALL BE 3/4" IN SIZE (TYPICAL).
3. SIZING OF LATERAL PIPE SHALL BE AS FOLLOWS:
0.75" 0-6 GPM
1" 7-12 GPM
1.25" 13-20 GPM
4. SIZING OF LATERAL PIPE FOR DRIPLINE (12" O.C. GRID WITH 0.6 GPH OR LESS EMITTERS) SHALL BE AS FOLLOWS:
0.75 0-500 FT
1" 501-1100 FT
1.25" 1101-2000 FT
1.5" 2001-3000 FT
5. EACH DRIP ZONE SHALL RECEIVE A SET OF AIR VENT/VACUUM RELIEF VALVE AT THE
HIGHS POINT AND FLUSH VALVES AT FARTHEST ENDS OF EACH SYSTEM AND EACH PLANTER.
6. CONTRACTOR TO INSTALL ALL IRRIGATION PIPING TO GO AROUND ALL UTILITY BOX, LIGHTS, SIGNS, ETC. (DRAWINGS ARE DIAGRAMMATIC).
7. FOR GRAPHIC CLARITY MAINLINE, REMOTE CONTROL VALVE AND LATERAL IS SHOWN OUTSIDE PLANTER. MAINLINE, REMOTE CONTROL VALVE AND LATERAL SHALL BE LOCATED WITHIN PLANTING AREAS. (TYPICAL)
WIRELESS WEATHER SENSOR AND RAIN SENSOR. MOUNT ON EVE OF BUILDING. INSTALL SENSOR OPEN TO THE SKY. COORDINATE AND CONFIRM EXACT LOCATION WITH OWNER'S REPRESENTATIVE.
REFER TO IRRIGATION LEGEND.
NEW REDUCED PRESSURE BACKFLOW ASSEMBLY WITH VIT STRONGBOX ENCLOSURE AND FREEZE BLANKET. REFER TO IRRIGATION LEGEND.
FLOW SENSOR.
REFER TO THE IRRIGATION LEGEND.
BRASS MASTER CONTROL VALVE
(LINE SIZE) REFER TO THE IRRIGATION LEGEND.
5 6
7 8
9 10
EZ-FLOW FERTILIZING SYSTEM WITH A 2" MAIN LINE CONNECTOR WITH BALL VALVE. CONTACT PHIL VANGENE WITH ANY QUESTION
CELL: 925-250-5885 EMAIL: [email protected]
11 1
2 1
2 3
4 5
6 78
9 10
11 SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 9
2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
7 DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
15'-0"
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
MVFSEZ
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2
# REV
AN
LA
23 Sa
41 KIFER DEVELOPMENT
NOT FO
1/16" =
IRRIGATION
SHEET L600 SHEET L600
POINT OF CONNECTION TO POTABLE WATER METER .
1.5" WATER METER WITH 2" SERVICE LINE FOR IRRIGATION MAXIMUM IRRIGATION DEMAND: 20 GPM AT A MINIMUM 65 PSI STATIC PRESSURE AT WATER METER LOCATION. CONTRACTOR TO FIELD VERIFIED THE PRESSURE BEFORE COMMENCING THE WORK. (IF THE PRESSURE AS NOTED IS NOT
ACCURATE A BOOSTER PUMP SHALL BE REQUIRED FOR THE SYSTEM TO FUNCTION PROPERLY).
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
CALL BEFORE YOU DIG
UNDERGROUND SERVICE ALERT
1" CONDUIT ROUTED THROUGH BUILDING TO 4TH LEVEL PLANTER, WITH PULL
ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE THE VALVES. (REFER TO SHEET L5.02)
2 SHEET NOTES:
1 IRRIGATION COORDINATION NOTES
1. PEX PIPING WITHIN STRUCTURE SHALL BE PROVIDED,
ROUTED AND INSTALLED BY PLUMBING CONTRACTOR.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND
PULL BOXES IN STRUCTURE. INSTALLATION OF WIRING TO
REMOTE CONTROL VALVES AND CONTROLLER SHALL BE
COMPLETED BY IRRIGATION CONTRACTOR.
1" CONDUIT ROUTED THROUGH BUILDING TO 8TH LEVEL PLANTER, WITH
PULL ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK. (REFER TO SHEET L5.03)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING TO 8TH LEVEL
PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR.
(REFER TO SHEET L5.03)
4 3
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING TO 4TH LEVEL
PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.02)
IRRIGATION CONTROLLER "C".
MOUNT ON WALL AT THIS LOCATION AS DETAILED. CONNECT TO 120 VOLT A.C.
ELECTRICAL SERVICE INSTALLED AT THIS LOCATION UNDER ELECTRICAL CONTRACT. IRRIGATION CONTRACTOR SHALL COORDINATE LOCATION OF ELECTRICAL SERVICE PRIOR TO CONSTRUCTION. (COORDINATE WITH GENERAL CONTRACTOR FOR FINAL LOCATION)-(2-WIRE CONTROLLER).
ELECTRICAL CONTRACTOR TO INSTALL 1" CONDUIT WITH PULL CORD FOR LOW VOLTAGE WIRES.
NOTES:
1. IRRIGATION EQUIPMENT MAY BE SHOWN WITHIN HARDSCAPE FOR GRAPHIC CLARITY ONLY. INSTALL ALL IRRIGATION EQUIPMENT WITHIN PLANTED AREAS. IRRIGATION PIPE
AND WIRE CROSSING BENEATH HARDSCAPE SURFACES SHALL BE CONTAINED WITHIN SLEEVING OR SCHEDULE 40 PVC CONDUIT. SLEEVING SIZE SHALL BE A MINIMUM OF TWO TIMES THE AGGREGATE DIAMETER OF ALL PIPES CONTAINED WITH SLEEVE. PROVIDE
VERTICAL SWEEP FOR ALL ELECTRICAL CONDUIT ON EACH SIDE OF HARDSCAPE AND TERMINATE ENDS AT 12" MINIMUM DEPTH AND 12" FROM HARDSCAPE SURFACE.
2. UNSIZED LATERAL LINE PIPING LOCATED DOWN STREAM OF 1" PIPING SHALL BE 3/4" IN SIZE (TYPICAL).
3. SIZING OF LATERAL PIPE SHALL BE AS FOLLOWS:
0.75" 0-6 GPM
1" 7-12 GPM
1.25" 13-20 GPM
4. SIZING OF LATERAL PIPE FOR DRIPLINE (12" O.C. GRID WITH 0.6 GPH OR LESS EMITTERS) SHALL BE AS FOLLOWS:
0.75 0-500 FT
1" 501-1100 FT
1.25" 1101-2000 FT
1.5" 2001-3000 FT
5. EACH DRIP ZONE SHALL RECEIVE A SET OF AIR VENT/VACUUM RELIEF VALVE AT THE
HIGHS POINT AND FLUSH VALVES AT FARTHEST ENDS OF EACH SYSTEM AND EACH PLANTER.
6. CONTRACTOR TO INSTALL ALL IRRIGATION PIPING TO GO AROUND ALL UTILITY BOX, LIGHTS, SIGNS, ETC. (DRAWINGS ARE DIAGRAMMATIC).
7. FOR GRAPHIC CLARITY MAINLINE, REMOTE CONTROL VALVE AND LATERAL IS SHOWN OUTSIDE PLANTER. MAINLINE, REMOTE CONTROL VALVE AND LATERAL SHALL BE LOCATED WITHIN PLANTING AREAS. (TYPICAL)
WIRELESS WEATHER SENSOR AND RAIN SENSOR. MOUNT ON EVE OF BUILDING. INSTALL SENSOR OPEN TO THE SKY. COORDINATE AND CONFIRM EXACT LOCATION WITH OWNER'S REPRESENTATIVE.
REFER TO IRRIGATION LEGEND.
NEW REDUCED PRESSURE BACKFLOW ASSEMBLY WITH VIT STRONGBOX ENCLOSURE AND FREEZE BLANKET. REFER TO IRRIGATION LEGEND.
FLOW SENSOR.
REFER TO THE IRRIGATION LEGEND.
BRASS MASTER CONTROL VALVE
(LINE SIZE) REFER TO THE IRRIGATION LEGEND.
5 6
7 8
9 10
EZ-FLOW FERTILIZING SYSTEM WITH A 2" MAIN LINE CONNECTOR WITH BALL VALVE. CONTACT PHIL VANGENE WITH ANY QUESTION
CELL: 925-250-5885 EMAIL: [email protected]
11 SHEET L600
1 2
1 2
3 4
5 6
78 9
10 11
Attachment 6
62 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 38
EASEMENTS SEE CIVIL PLANS
4TH LVL TREE - MEDIUM 23
BETULA NIGRA - MEDIUM TO HIGH
ACER CIRCINATUM - MEDIUM
AESCULUS X CARNEA - MEDIUM
4TH LVL TREE - LOW 24
LAURUS NOBILIS `SARATOGA` - LOW
OLEA EUROPAEA ‘SWAN HILL’ - LOW
4TH LVL PLANTING AREA - MEDIUM 1,466 SF
SESLERIA AUTUMNALIS - MEDIUM
4TH LVL PLANTING AREA - LOW 3,530 SF
LAURUS NOBILIS - LOW
OLEA EUROPAEA `LITTLE OLLIE` - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
IRRIGATION PL
1" CONDUIT ROUTED THROUGH BUILDING FROM BELOW, WITH PULL ROPE FOR
IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE THE VALVES. (REFER TO SHEET L5.01)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING FROM BELOW TO
THIS LOCATION WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.01)
2 SHEET NOTES:
1 IRRIGATION COORDINATION NOTES
1. PEX PIPING WITHIN STRUCTURE SHALL BE PROVIDED,
ROUTED AND INSTALLED BY PLUMBING CONTRACTOR.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND
PULL BOXES IN STRUCTURE. INSTALLATION OF WIRING TO
REMOTE CONTROL VALVES AND CONTROLLER SHALL BE
COMPLETED BY IRRIGATION CONTRACTOR.
IRRIGATION EQUIPMENT REFER TO IRRIGATION SHEET L5.01
NOTES:
1 2
1 2
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
1" CONDUIT ROUTED THROUGH BUILDING FROM 4TH LEVEL, TO 8TH LEVEL
PLANTER, WITH PULL ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK. (REFER TO SHEET L5.03)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING FROM 4TH LEVEL TO 8TH LEVEL PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.03)
4 3
4 3
1/32” = 1’-0”
SITE PLAN - L502
23 24
1,466 SF
3,530 SF
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L502
1/16" = 1'-0"
IRRIGATION PLAN LEVEL 4
1" CONDUIT ROUTED THROUGH BUILDING FROM BELOW, WITH PULL ROPE FOR
IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE THE VALVES. (REFER TO SHEET L5.01)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING FROM BELOW TO
THIS LOCATION WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.01)
2 SHEET NOTES:
1 IRRIGATION COORDINATION NOTES
1. PEX PIPING WITHIN STRUCTURE SHALL BE PROVIDED,
ROUTED AND INSTALLED BY PLUMBING CONTRACTOR.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND
PULL BOXES IN STRUCTURE. INSTALLATION OF WIRING TO
REMOTE CONTROL VALVES AND CONTROLLER SHALL BE
COMPLETED BY IRRIGATION CONTRACTOR.
IRRIGATION EQUIPMENT REFER TO IRRIGATION SHEET L5.01
NOTES:
1 2
1 2
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
1" CONDUIT ROUTED THROUGH BUILDING FROM 4TH LEVEL, TO 8TH LEVEL
PLANTER, WITH PULL ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK. (REFER TO SHEET L5.03)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING FROM 4TH LEVEL TO 8TH LEVEL PLANTER, WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.03)
4 3
4 3
SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 9
2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
7 DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
LANDSCAPE - IRRIGATION LEVEL 4
Attachment 6
63 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 39
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
8TH LVL PLANTING AREA - LOW - 5 GAL. 220 SF
LAURUS NOBILIS - LOW
OLEA EUROPAEA `LITTLE OLLIE` - VERY LOW
AGAVE `BLUE FLAME` - LOW
8TH LVL PLANTING AREA - MEDIUM - 5 GAL. 65 SF
SESLERIA AUTUMNALIS - MEDIUM
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
IRRIGATION PL
1" CONDUIT ROUTED THROUGH BUILDING FROM BELOW, WITH PULL ROPE
FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE THE VALVES. (REFER TO SHEET L5.01)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING FROM BELOW TO
THIS LOCATION WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.01)
2 SHEET NOTES:
1 IRRIGATION COORDINATION NOTES
1. PEX PIPING WITHIN STRUCTURE SHALL BE PROVIDED,
ROUTED AND INSTALLED BY PLUMBING CONTRACTOR.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND
PULL BOXES IN STRUCTURE. INSTALLATION OF WIRING TO
REMOTE CONTROL VALVES AND CONTROLLER SHALL BE
COMPLETED BY IRRIGATION CONTRACTOR.
IRRIGATION EQUIPMENT REFER TO IRRIGATION SHEET L5.01
NOTES:
1 2
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
3 1" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING WITH A SINGLE
PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. TO SERVICE SECOND PODIUM AS SHOWN.
3 1" CONDUIT ROUTED THROUGH BUILDING, WITH PULL ROPE FOR IRRIGATION
CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE SECOND PODIUM AS SHOWN.
4 4
6 5
1" CONDUIT ROUTED THROUGH BUILDING FROM 4TH LEVEL BELOW, WITH
PULL ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK. (REFER TO SHEET L5.02)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING FROM 4TH LEVEL
BELOW TO THIS LOCATION WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.02)
6 5
1/32” = 1’-0”
SITE PLAN - L503
36'-5"
0 SF
SF
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L503
1/16" = 1'-0"
IRRIGATION PLAN LEVEL 8
1" CONDUIT ROUTED THROUGH BUILDING FROM BELOW, WITH PULL ROPE
FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE THE VALVES. (REFER TO SHEET L5.01)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING FROM BELOW TO
THIS LOCATION WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.01)
2 SHEET NOTES:
1 IRRIGATION COORDINATION NOTES
1. PEX PIPING WITHIN STRUCTURE SHALL BE PROVIDED,
ROUTED AND INSTALLED BY PLUMBING CONTRACTOR.
2. ELECTRICAL CONTRACTOR SHALL PROVIDE CONDUIT AND
PULL BOXES IN STRUCTURE. INSTALLATION OF WIRING TO
REMOTE CONTROL VALVES AND CONTROLLER SHALL BE
COMPLETED BY IRRIGATION CONTRACTOR.
IRRIGATION EQUIPMENT REFER TO IRRIGATION SHEET L5.01
NOTES:
1 2
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
3 1" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING WITH A SINGLE
PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. TO SERVICE SECOND PODIUM AS SHOWN.
3 1" CONDUIT ROUTED THROUGH BUILDING, WITH PULL ROPE FOR IRRIGATION
CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK TO SERVICE SECOND PODIUM AS SHOWN.
4 4
6 5
1" CONDUIT ROUTED THROUGH BUILDING FROM 4TH LEVEL BELOW, WITH
PULL ROPE FOR IRRIGATION CONTROL WIRE (TWO-WIRE) TO BE INSTALLED UNDER ELECTRICAL SCOPE OF WORK. (REFER TO SHEET L5.02)
1.5" PEX MAIN LINE TO BE ROUTED THROUGH BUILDING FROM 4TH LEVEL
BELOW TO THIS LOCATION WITH A SINGLE PENETRATION AND TERMINATED WITH PEX FEMALE ADAPTER STUB-OUT BY BUILDING PLUMBING CONTRACTOR. (REFER TO SHEET L5.02)
6 5
SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 9
2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
7 DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
LANDSCAPE - IRRIGATION LEVEL 8
Attachment 6
64 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 37
SHEET TITLE:
DISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
08.05. 2022
D# REVISION LIST
ANDREA COCHRAN
LANDSCAPE ARCHITECTURE
2325 Third Street #210
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
1/16" = 1'-0"
IRRIGATION NOTES AND
LEGEND
SHEET L601
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 fax 925.932.5671
IRRIGATION LEGEND - PLUMBING & CIVIL
ELECTRICAL
CONDUIT:
SHOWN FOR REFERENCE ONLY, SEE ELECTRICAL
PLANS FOR ROUTING THROUGH STRUCTURE.
IRRIGATION POINT OF CONNECTION TO PEX PIPE AND
ELECTRICAL CONDUIT FOR COMMUNICATION WIRES
ROUTED THROUGH THE BUILDING AND STUBBED OUT INTO
PLANTERS WHERE SHOWN. WORK TO BE BY ELECTRICAL
AND PLUMBING CONTRACTORS.
SYMBOL DESCRIPTIONMODEL NUMBER
PEX PIPE. SHOWN FOR REFERENCE ONLY, SEE
PLUMBING PLANS FOR ROUTING THROUGH
STRUCTURE.
PEX
MAIN LINE:
IRRIGATION NOTES
1. THESE IRRIGATION DRAWINGS ARE DIAGRAMMATIC AND INDICATIVE OF THE WORK TO BE INSTALLED. ALL PIPING, VALVES, AND OTHER IRRIGATION
COMPONENTS MAY BE SHOWN WITHIN PAVED AREAS FOR GRAPHIC CLARITY ONLY AND ARE TO BE INSTALLED WITHIN PLANTING AREAS. DUE TO THE SCALE
OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, SLEEVES, CONDUIT, AND OTHER ITEMS WHICH MAY BE REQUIRED. INVESTIGATE
THE STRUCTURAL AND FINISHED CONDITION AFFECTING THE CONTRACT WORK
INCLUDING OBSTRUCTIONS, GRADE DIFFERENCES OR AREA DIMENSIONAL DIFFERENCES. IN THE EVENT OF FIELD DISCREPANCY WITH CONTRACT
DOCUMENTS, PLAN THE INSTALLATION WORK ACCORDINGLY BY
NOTIFICATION AND APPROVAL OF A AUTHORIZED COSTCO REPRESENTATIVE AND ACCORDING TO THE CONTRACT SPECIFICATIONS. NOTIFY AND
COORDINATE IRRIGATION CONTRACT WORK WITH APPLICABLE CONTRACTORS
FOR THE LOCATION AND INSTALLATION OF PIPE, CONDUIT OR SLEEVES
THROUGH OR UNDER WALLS, ROADWAYS, PAVING AND STRUCTURES BEFORE CONSTRUCTION. IN THE EVENT THESE NOTIFICATIONS ARE NOT PERFORMED, THE CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR REQUIRED REVISIONS.
2. LANDSCAPE AND IRRIGATION MAINTENANCE SCHEDULE, IRRIGATION AUDIT,
IRRIGATION SURVEY, AND IRRIGATION WATER USE ANALYSIS SHALL BE
SUBMITTED WITH THE CERTIFICATE OF COMPLETION IN COMPLIANCE WITH WATER EFFICIENT LANDSCAPE ORDINANCE AB 1881 PRIOR TO COUNTY ACCEPTANCE.
3. THE INTENT OF THIS IRRIGATION SYSTEM IS TO PROVIDE THE MINIMUM AMOUNT OF WATER REQUIRED TO SUSTAIN GOOD PLANT HEALTH.
4. THE LANDSCAPE CONTRACTOR SHALL SCHEDULE A POST CONSTRUCTION
MEETING WHICH INCLUDES REPRESENTATIVES OF THE IRRIGATION CONTROLLER
MANUFACTURER, THE MAINTENANCE CONTRACTOR, THE OWNE'R
REPRESENTATIVE AND THE IRRIGATION CONTRACTOR AT THE SITE FOR
INSTRUCTION ON THE PROPER PROGRAMMING AND OPERATION OF THE IRRIGATION CONTROLLER.
5. THE LANDSCAPE CONTRACTOR TO PROGRAM THE IRRIGATION
CONTROLLER TO PROVIDE THE MINIMUM AMOUNT OF WATER NEEDED TO SUSTAIN GOOD PLANT HEALTH. THIS INCLUDES MAKING ADJUSTMENTS TO THE
PROGRAM FOR SEASONAL WEATHER CHANGES, PLANT MATERIAL, WATER REQUIREMENTS, MOUNDS, SLOPES, SUN, SHADE AND WIND EXPOSURE.
6. IT IS THE RESPONSIBILITY OF A LICENSED ELECTRICAL CONTRACTOR TO PROVIDE 120 VOLT A.C. (2.5 AMP DEMAND TO CONTROLLER) ELECTRICAL SERVICE TO THE CONTROLLER LOCATION. IT IS THE RESPONSIBILITY OF THE IRRIGATION
CONTRACTOR TO COORDINATE THE ELECTRICAL SERVICE STUB-OUT TO THE CONTROLLER. PROVIDE PROPER GROUNDING PER CONTROLLER
MANUFACTURER'S INSTRUCTIONS AND IN ACCORDANCE WITH LOCAL CODES.
7. PROVIDE CONTROLLER WITH ITS OWN GROUND ROD. SEPARATE THE GROUND ROD BY A MINIMUM OF EIGHT FEET. THE GROUND ROD SHALL BE AN EIGHT FOOT LONG BY 5/8" DIAMETER U.L. APPROVED COPPER CLAD ROD. INSTALL NO MORE THAN 6" OF THE GROUND ROD ABOVE FINISH GRADE. CONNECT #6 GAUGE WIRE WITH A U.L. APPROVED GROUND ROD CLAMP TO ROD AND
BACK TO GROUND SCREW AT BASE OF CONTROLLER WITH APPROPRIATE CONNECTOR. MAKE THIS WIRE AS SHORT AS POSSIBLE, AVOIDING KINKS OR BENDING.
8. PROVIDE IRRIGATION CONTROLLER WITH ITS OWN INDEPENDENT LOW VOLTAGE COMMON GROUND WIRE.
9. INSTALL NEW BATTERIES IN THE IRRIGATION CONTROLLER TO RETAIN PROGRAM IN MEMORY DURING TEMPORARY POWER FAILURES. USE QUANTITY, TYPE AND SIZE REQUIRED AS PER MANUFACTURER'S INSTRUCTIONS.
10. FOR PROPER INSTALLATION OF THE 2-WIRE CABLE CONTRACTOR SHALL CONTACT CONTROLLER REPRESENTATIVE FOR A PRE-CONSTRUCTION MEETING.
11. IRRIGATION CONTROL WIRES: SOLID COPPER WITH U.L. APPROVAL FOR DIRECT BURIAL IN GROUND. SIZE #14AWG WIRE WITH A JACKETED 2-CONDUCTOR.
PREFERRED WIRE MAKE AND MODEL IS THE PAIGE IRRIGATION WIRE, SPEC P7350D (TORO). ALL SPLICING SHALL BE MADE WITH 3-M DBR/Y-6 WATERPROOF SPLICE KIT.
12. DECODER GROUNDING SHALL BE PROVIDED EVERY (500 FEET OR EVERY 8 DECODERS, WHICHEVER IS SMALLER. GROUND WITH A 8' GROUNDING ROD.
INCLUDE A SURGE ARRESTOR AT EACH GROUNDING LOCATION. A SPLIT BOLT
CONNECTION TO BE USED TO CONNECT THE SURGE DEVICE TO THE GROUND WIRE WITH A DBR/Y-6 WATERPROOF CONNECTOR.
13. SPLICING OF JACKETED 2-WIRE IS PERMITTED IN VALVE BOXES ONLY. LEAVE A 36" LONG COIL OF WIRE AT EACH SPLICE AND A 36" LONG EXPANSION LOOP EVERY 100 FEET ALONG WIRE RUN.
14. INSTALL BLACK PLASTIC VALVE BOXES AND LIDS WITH BOLT DOWN, NON HINGED COVER MARKED "IRRIGATION". BOX BODY SHALL HAVE KNOCK OUTS.
ACCEPTABLE VALVE BOX MANUFACTURER'S INCLUDE NDS, CARSON OR APPROVED EQUAL.
15. INSTALL REMOTE CONTROL VALVE BOXES 12" FROM WALK, CURB, BUILDING OR LANDSCAPE FEATURE. AT MULTIPLE VALVE BOX GROUPS, INSTALL EACH BOX
AN EQUAL DISTANCE FROM THE WALK, CURB, BUILDING OR LANDSCAPE FEATURE AND PROVIDE 12" BETWEEN BOX TOPS. ALIGN THE SHORT SIDE OF
RECTANGULAR VALVE BOXES PARALLEL TO WALK, CURB, BUILDING OR LANDSCAPE FEATURE.
16. LOCATE BUBBLERS ON UPHILL SIDE OF TREE.
17. INSTALL A HUNTER HCV SERIES, KBI CV SERIES, OR APPROVED EQUAL SPRING
LOADED CHECK VALVE IN SPRINKLER RISER ASSEMBLIES WHERE LOW OUTLET DRAINAGE WILL CAUSE EROSION AND/OR EXCESS WATER.
18. THE IRRIGATION SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE SHOWN ON THE IRRIGATION DRAWINGS. VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE WATER
PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO THE OWNER'S REPRESENTATIVE.
19. IRRIGATION DEMAND: REFER TO PLANS.
20. PIPE SIZING SHOWN ON THE DRAWINGS IS TYPICAL. AS CHANGES IN LAYOUT
OCCUR DURING STAKING AND CONSTRUCTION THE SIZE MAY NEED TO BE ADJUSTED ACCORDINGLY.
21. PIPE THREAD SEALANT COMPOUND SHALL BE RECTOR SEAL #5.
22. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR CHANGES IN THE
IRRIGATION LAYOUT AND VALVE ZONING DUE TO VARIATIONS IN THE EXISTING SITE CONDITIONS SUCH AS EXPOSURE FROM BUILDINGS, TREES, ETC., AS WELL AS SLOPE AND SOIL CONDITIONS. THE CONTRACTOR SHALL NOTIFY
THE OWNER'S REPRESENTATIVE OF THE PROPOSED CHANGES PRIOR TO INSTALLATION FOR APPROVAL.
23. NOTIFY LOCAL JURISDICTIONS FOR INSPECTION AND TESTING OF BACKFLOW PREVENTION DEVICE. TESTING SHALL BE PERFORMED BY A LICENSED BACKFLOW TESTER AND TESTING SHALL BE DONE BEFORE WATER IS USED.
24. LOCATE AND PROTECT ALL UTILITES PRIOR TO CONSTRUCTION. DO NOT DAMAGE ANY UTITLIES, PAVING, OR STRUCTURES. CONTRACTOR TO MAKE ANY NECESSARY REPAIRS AT NO ADDITIONAL COST TO COSTCO.
25. REMOVE ALL IRRIGATION CONSTRUCTION DEBRIS FROM THE SITE AND LEAVE THE AREA CLEAN ACCEPTABLE TO THE OWNERS REPRESENTATIVE.
26. THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE SITE FOLLOWING ACCEPTANCE OF THE WORK BY THE OWNERS REPRESENTATIVE. MAKE
CORRECTIONS OR REPAIRS TO THE IRRIGATION AS REQUIRED, PRIOR TO COMPLETION OF THE MAINTENANCE PERIOD. REFER TO SPECIFICATIONS FOR THE TIME PERIOD.
27. ANY VARIANCE IN THE FIELD TO THE DRAWINGS AND SPECIFICATIONS WILL
REQUIRE THE SUBMITTAL OF A SHOP DRAWING FROM THE CONTRACTOR AND AN APPROVAL BY THE OWNERS REPRESENTATIVE. CHANGES BY THE
CONTRACTOR WITHOUT COSTCO'S APPROVAL SHALL BE PAID FOR BY THE CONTRACTOR.
28. THE IRRIGATION SYSTEM IS PROTECTED WITH A NORMALLY CLOSED MASTER VALVE. TO OPERATE A QUICK COUPLER VALVE AN OPEN STATION ON THE
CONTROLLER WILL REQUIRE ACTIVATION TO ALLOW WATER TO ENTER THE MAIN LINE.
"A Landscape Irrigation Audit is required. This Audit must be completed by a Certified Landscape Irrigation Auditor, not the designer or installer. The Audit must be submitted to the Building Department, with Certificate of Completion (Appendix C) as required by the Department of Water Resources, prior to scheduling a Final Inspection of the Water Efficient Landscape permit." LATERAL LINE:
SYMBOL
NOZZLE
GPMNUMBER DESCRIPTION
OPERATING RADIUS
(FEET)
OPERATING
PSI
IRRIGATION LEGEND
SLEEVING: 1120-CL. 200 PVC PLASTIC PIPE. COVER TO BE AS
INDICATED IN SPECIFICATIONS OR AS INDICATED ABOVE
FOR PIPE DEPTH OF COVER.
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH
SCHEDULE 40 PVC SOLVENT WELD FITTINGS.
18" COVER.
MAIN LINE: 2" THROUGHOUT
3/4" AND LARGER:
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH
SCHEDULE 40 PVC SOLVENT WELD FITTINGS.
12" COVER. (18 COVER UNDER PAVEMENT SECTION)
LATERAL LINE COVER FOR THE ROOF TO BE 6"-8" COVER
WTPRO3-C-
2W48-SWM
WeatherTRAK ET PRO3 2-WIRE 48 STATION CONTROLLER IN A
STAINLESS STEEL WALL MOUNTED ENCLOSURE.
WT2W-SVD-11 WEATHERTRAK DECODER (1 PER VALVE)
WT2W-LSP WEATHERTRAK SURGE ARRESTOR (1 EVERY 500 FEET ALONG MAIN) REFER TO DETAILS FOR INSTALLATION INSTRUCTIONS.
ROUTE TWO WIRE CABLE TO ALL REMOTE CONTROL VALVES. SIZE #14AWG WIRE WITH A JACKETED 2-CONDUCTOR. PREFERRED WIRE MAKE AND MODEL IS PAIGE ELECTRIC WIRE P7072D. ALL SPLICING SHALL BE MADE WITH 3-M DBR/Y-6 WATERPROOF SPLICE KITS OR APPROVED EQUAL. INSTALL 2 WIRE CABLE WITHIN 1.25" SCH 40 ELECTRICAL CONDUIT.
PULL BOXES SHALL BE LOCATED EVERY 200' NO SPLICES ARE ALLOWED BETWEEN VALVES. REFER TO DETAIL FOR INSTALLATION INSTRUCTIONS.
NOT SHOWN ON
PLANS
MV
WeatherTRAK 1" FLOW SENSOR (1-40 GPM)WT-FS-100-CSTFS
1 LA
CIM-5YA 5 YEAR EXTENSION OF WeatherTRAK Central.
T-YD-500-34 TORO DRIPLINE AIR RELIEF VALVE
WLT-0500-T NDS SCH 40 BALL VALVE OR APPROVED EQUAL
700-1-OMR-100 IRRITROL REMOTE CONTROL VALVE WITH PRESSURE REGULATOR (LOCATED IN EQUIPMENT ROOM)
700-1"/
HFR-100-075-40
IRRITROL 700 SERIES REMOTE CONTROL VALVE WITH HUNTER FILTER AND PRESSURE REGULATOR (40 PSI) AND A 1" FILTER (IN GROUND VALVES) T-580-A NIBCO BRASS BALL VALVE (LINE SIZE)
DRIPLINE REMOTE CONTROL VALVEPVC LATERAL
975XL-1.5" WILKINS REDUCED PRESSURE BACKFLOW ASSEMBLY
CONTROLLER AND STATION NUMBER
AREA (SQ. FT.)
FLOW (GPM)
REMOTE CONTROL VALVE SIZE (IN INCHES)
ASSOCIATED REMOTE CONTROL VALVE
WATER USE CLASSIFICATION OF ZONE
APPLICATION RATE (IN/HR) or DRIPLINE SPACING
570-DRIP-IND TORO POP-UP DRIPLINE INDICATOR WITH SIDE INLET.
DRIP ZONE:
TORO DL2000 SERIES DRIPLINE WITH DL2000 INSERT
FITTINGS, PART #RGP-212. TUBING TO BE INSTALLED 4"
BELOW GRADE IN A 12" O.C. GRID ACCORDING TO
DETAILS. SIZE EXHAUST HEADERS AS FOLLOWS: 1": 0-10
GPM, 1.25": 11-20 GPM. ALL EXHAUST HEADERS SHALL BE
1" SCH 40 PVC OR 1" SCH 40 FLEXIBLE PVC. USE SCH. 40
PVC SOLVENT WELD FITTINGS. EXTEND PVC HEADERS TO
THE ENDS OF ALL DRIP ZONES TO BALANCE FLOW IF
REQUIRED. SEE DETAILS FOR FURTHER INFORMATION.
DRIPLINE REMOTE CONTROL VALVE
APPROXIMATE CONNECTION POINT BETWEEN DRIPLINE
TUBING AND PVC SUPPLY WHEN DRIP ZONE IS LESS THAN
3 GPM AND NO PVC SUPPLY/EXHUST HEADERS ARE
NEEDED. REFER TO DRIPLINE TUBING CONNECTION
DETAIL FOR MORE INFORMATION.
SUPPLY
HEADER
EXHAUST
HEADER
DRIP ZONE
EXTENTS
PVC LATERAL
TORO POP-UP SPRAY
SPRINKLER (SHRUB)
8-10
10-12
12-151.2,0.6
0.75,0.37
1,0.5,0.23
570Z-12P-PRX-COM
O-T-12FP,12HP,12QP
570Z-12P-PRX-COM
O-T-10FP,10HP,10QP
570Z-12P-PRX-COM
O-T-15FP,15HP,15QP
DRIPLINE
LATERAL LINE:
3/4" AND LARGER:
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH SCHEDULE 40
PVC SOLVENT WELD FITTINGS. 12" COVER. (18" COVER
UNDER PAVING)
33DNP RAIN BIRD QUICK COUPLING VALVE
WT-MV-SNC WeatherTRAK BRASS MASTER VALVE (NORMALLY CLOSE)-(LINE SIZE)
TORO POP-UP SPRAY
SPRINKLER (SHRUB)
TORO POP-UP SPRAY
SPRINKLER (SHRUB)
30 30
30 0.066 30 TRICKLETORO BUBBLE (SHRUB)
MIN. 1 PER SHRUB (REFER TO
BUBBLER DETAIL FOR
QUANTITY OF BUBBLERS PER
SHRUB SIZE)
DB-04-PC-CV
WATER CONSERVATION STATEMENT
RUSSELL D MITCHELL AND ASSOCIATES, INC. (RMA) HAVE COMPLIED
WITH THE CRITERIA OF THE MODEL WATER EFFICIENT LANDSCAPE
ORDINANCE AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN.
JOSE L. CRUZ
IRRIGATION CONSULTATION-PROJECT MANGER
EZ-FLOW FERTILIZING SYSTEM WITH A 2" MAIN LINE CONNECTOR WITH BALL VALVE. CONTACT PHIL VANGENE WITH ANY QUESTION
CELL: 925-250-5885 EMAIL: [email protected]
EZ003-CX
CBV-2
ON GRADE DL2000
BROWNLINE DRIP RING FOR
TREES-SEE DETAIL
0.10 30 TRICKLET-PC-B-18-53-12
GENERAL SITE NOTES - L504
SHEET TITLE:
DAISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
08.05. 2022
DA# REVISION LIST
ANDREA COCHRAN
LANDSCAPE ARCHITECTURE
2325 Third Street #210
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
1/16" = 1'-0"
IRRIGATION NOTES AND
LEGEND
SHEET L601
Irrigation Consultant:
2760 Camino Diablo
IRRIGATION LEGEND - PLUMBING & CIVIL
ELECTRICAL
CONDUIT:
SHOWN FOR REFERENCE ONLY, SEE ELECTRICAL
PLANS FOR ROUTING THROUGH STRUCTURE.
IRRIGATION POINT OF CONNECTION TO PEX PIPE AND
ELECTRICAL CONDUIT FOR COMMUNICATION WIRES
ROUTED THROUGH THE BUILDING AND STUBBED OUT INTO
PLANTERS WHERE SHOWN. WORK TO BE BY ELECTRICAL
AND PLUMBING CONTRACTORS.
SYMBOL DESCRIPTIONMODEL NUMBER
PEX PIPE. SHOWN FOR REFERENCE ONLY, SEE
PLUMBING PLANS FOR ROUTING THROUGH
STRUCTURE.
PEX
MAIN LINE:
IRRIGATION NOTES
1. THESE IRRIGATION DRAWINGS ARE DIAGRAMMATIC AND INDICATIVE OF THE WORK TO BE INSTALLED. ALL PIPING, VALVES, AND OTHER IRRIGATION
COMPONENTS MAY BE SHOWN WITHIN PAVED AREAS FOR GRAPHIC CLARITY ONLY AND ARE TO BE INSTALLED WITHIN PLANTING AREAS. DUE TO THE SCALE
OF THE DRAWINGS, IT IS NOT POSSIBLE TO INDICATE ALL OFFSETS, FITTINGS, SLEEVES, CONDUIT, AND OTHER ITEMS WHICH MAY BE REQUIRED. INVESTIGATE
THE STRUCTURAL AND FINISHED CONDITION AFFECTING THE CONTRACT WORK
INCLUDING OBSTRUCTIONS, GRADE DIFFERENCES OR AREA DIMENSIONAL DIFFERENCES. IN THE EVENT OF FIELD DISCREPANCY WITH CONTRACT
DOCUMENTS, PLAN THE INSTALLATION WORK ACCORDINGLY BY
NOTIFICATION AND APPROVAL OF A AUTHORIZED COSTCO REPRESENTATIVE AND ACCORDING TO THE CONTRACT SPECIFICATIONS. NOTIFY AND
COORDINATE IRRIGATION CONTRACT WORK WITH APPLICABLE CONTRACTORS
FOR THE LOCATION AND INSTALLATION OF PIPE, CONDUIT OR SLEEVES
THROUGH OR UNDER WALLS, ROADWAYS, PAVING AND STRUCTURES BEFORE CONSTRUCTION. IN THE EVENT THESE NOTIFICATIONS ARE NOT PERFORMED, THE CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR REQUIRED REVISIONS.
2. LANDSCAPE AND IRRIGATION MAINTENANCE SCHEDULE, IRRIGATION AUDIT,
IRRIGATION SURVEY, AND IRRIGATION WATER USE ANALYSIS SHALL BE
SUBMITTED WITH THE CERTIFICATE OF COMPLETION IN COMPLIANCE WITH WATER EFFICIENT LANDSCAPE ORDINANCE AB 1881 PRIOR TO COUNTY ACCEPTANCE.
3. THE INTENT OF THIS IRRIGATION SYSTEM IS TO PROVIDE THE MINIMUM AMOUNT OF WATER REQUIRED TO SUSTAIN GOOD PLANT HEALTH.
4. THE LANDSCAPE CONTRACTOR SHALL SCHEDULE A POST CONSTRUCTION
MEETING WHICH INCLUDES REPRESENTATIVES OF THE IRRIGATION CONTROLLER
MANUFACTURER, THE MAINTENANCE CONTRACTOR, THE OWNE'R
REPRESENTATIVE AND THE IRRIGATION CONTRACTOR AT THE SITE FOR
INSTRUCTION ON THE PROPER PROGRAMMING AND OPERATION OF THE IRRIGATION CONTROLLER.
5. THE LANDSCAPE CONTRACTOR TO PROGRAM THE IRRIGATION
CONTROLLER TO PROVIDE THE MINIMUM AMOUNT OF WATER NEEDED TO SUSTAIN GOOD PLANT HEALTH. THIS INCLUDES MAKING ADJUSTMENTS TO THE
PROGRAM FOR SEASONAL WEATHER CHANGES, PLANT MATERIAL, WATER REQUIREMENTS, MOUNDS, SLOPES, SUN, SHADE AND WIND EXPOSURE.
6. IT IS THE RESPONSIBILITY OF A LICENSED ELECTRICAL CONTRACTOR TO PROVIDE 120 VOLT A.C. (2.5 AMP DEMAND TO CONTROLLER) ELECTRICAL SERVICE TO THE CONTROLLER LOCATION. IT IS THE RESPONSIBILITY OF THE IRRIGATION
CONTRACTOR TO COORDINATE THE ELECTRICAL SERVICE STUB-OUT TO THE CONTROLLER. PROVIDE PROPER GROUNDING PER CONTROLLER
MANUFACTURER'S INSTRUCTIONS AND IN ACCORDANCE WITH LOCAL CODES.
7. PROVIDE CONTROLLER WITH ITS OWN GROUND ROD. SEPARATE THE GROUND ROD BY A MINIMUM OF EIGHT FEET. THE GROUND ROD SHALL BE AN EIGHT FOOT LONG BY 5/8" DIAMETER U.L. APPROVED COPPER CLAD ROD. INSTALL NO MORE THAN 6" OF THE GROUND ROD ABOVE FINISH GRADE. CONNECT #6 GAUGE WIRE WITH A U.L. APPROVED GROUND ROD CLAMP TO ROD AND
BACK TO GROUND SCREW AT BASE OF CONTROLLER WITH APPROPRIATE CONNECTOR. MAKE THIS WIRE AS SHORT AS POSSIBLE, AVOIDING KINKS OR BENDING.
8. PROVIDE IRRIGATION CONTROLLER WITH ITS OWN INDEPENDENT LOW VOLTAGE COMMON GROUND WIRE.
9. INSTALL NEW BATTERIES IN THE IRRIGATION CONTROLLER TO RETAIN PROGRAM IN MEMORY DURING TEMPORARY POWER FAILURES. USE QUANTITY, TYPE AND SIZE REQUIRED AS PER MANUFACTURER'S INSTRUCTIONS.
10. FOR PROPER INSTALLATION OF THE 2-WIRE CABLE CONTRACTOR SHALL CONTACT CONTROLLER REPRESENTATIVE FOR A PRE-CONSTRUCTION MEETING.
11. IRRIGATION CONTROL WIRES: SOLID COPPER WITH U.L. APPROVAL FOR DIRECT BURIAL IN GROUND. SIZE #14AWG WIRE WITH A JACKETED 2-CONDUCTOR.
PREFERRED WIRE MAKE AND MODEL IS THE PAIGE IRRIGATION WIRE, SPEC P7350D (TORO). ALL SPLICING SHALL BE MADE WITH 3-M DBR/Y-6 WATERPROOF SPLICE KIT.
12. DECODER GROUNDING SHALL BE PROVIDED EVERY (500 FEET OR EVERY 8 DECODERS, WHICHEVER IS SMALLER. GROUND WITH A 8' GROUNDING ROD.
INCLUDE A SURGE ARRESTOR AT EACH GROUNDING LOCATION. A SPLIT BOLT
CONNECTION TO BE USED TO CONNECT THE SURGE DEVICE TO THE GROUND WIRE WITH A DBR/Y-6 WATERPROOF CONNECTOR.
13. SPLICING OF JACKETED 2-WIRE IS PERMITTED IN VALVE BOXES ONLY. LEAVE A 36" LONG COIL OF WIRE AT EACH SPLICE AND A 36" LONG EXPANSION LOOP EVERY 100 FEET ALONG WIRE RUN.
14. INSTALL BLACK PLASTIC VALVE BOXES AND LIDS WITH BOLT DOWN, NON HINGED COVER MARKED "IRRIGATION". BOX BODY SHALL HAVE KNOCK OUTS.
ACCEPTABLE VALVE BOX MANUFACTURER'S INCLUDE NDS, CARSON OR APPROVED EQUAL.
15. INSTALL REMOTE CONTROL VALVE BOXES 12" FROM WALK, CURB, BUILDING OR LANDSCAPE FEATURE. AT MULTIPLE VALVE BOX GROUPS, INSTALL EACH BOX
AN EQUAL DISTANCE FROM THE WALK, CURB, BUILDING OR LANDSCAPE FEATURE AND PROVIDE 12" BETWEEN BOX TOPS. ALIGN THE SHORT SIDE OF
RECTANGULAR VALVE BOXES PARALLEL TO WALK, CURB, BUILDING OR LANDSCAPE FEATURE.
16. LOCATE BUBBLERS ON UPHILL SIDE OF TREE.
17. INSTALL A HUNTER HCV SERIES, KBI CV SERIES, OR APPROVED EQUAL SPRING
LOADED CHECK VALVE IN SPRINKLER RISER ASSEMBLIES WHERE LOW OUTLET DRAINAGE WILL CAUSE EROSION AND/OR EXCESS WATER.
18. THE IRRIGATION SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE SHOWN ON THE IRRIGATION DRAWINGS. VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE WATER
PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO THE OWNER'S REPRESENTATIVE.
19. IRRIGATION DEMAND: REFER TO PLANS.
20. PIPE SIZING SHOWN ON THE DRAWINGS IS TYPICAL. AS CHANGES IN LAYOUT
OCCUR DURING STAKING AND CONSTRUCTION THE SIZE MAY NEED TO BE ADJUSTED ACCORDINGLY.
21. PIPE THREAD SEALANT COMPOUND SHALL BE RECTOR SEAL #5.
22. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR CHANGES IN THE
IRRIGATION LAYOUT AND VALVE ZONING DUE TO VARIATIONS IN THE EXISTING SITE CONDITIONS SUCH AS EXPOSURE FROM BUILDINGS, TREES, ETC., AS WELL AS SLOPE AND SOIL CONDITIONS. THE CONTRACTOR SHALL NOTIFY
THE OWNER'S REPRESENTATIVE OF THE PROPOSED CHANGES PRIOR TO INSTALLATION FOR APPROVAL.
23. NOTIFY LOCAL JURISDICTIONS FOR INSPECTION AND TESTING OF BACKFLOW PREVENTION DEVICE. TESTING SHALL BE PERFORMED BY A LICENSED BACKFLOW TESTER AND TESTING SHALL BE DONE BEFORE WATER IS USED.
24. LOCATE AND PROTECT ALL UTILITES PRIOR TO CONSTRUCTION. DO NOT DAMAGE ANY UTITLIES, PAVING, OR STRUCTURES. CONTRACTOR TO MAKE ANY NECESSARY REPAIRS AT NO ADDITIONAL COST TO COSTCO.
25. REMOVE ALL IRRIGATION CONSTRUCTION DEBRIS FROM THE SITE AND LEAVE THE AREA CLEAN ACCEPTABLE TO THE OWNERS REPRESENTATIVE.
26. THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE SITE FOLLOWING ACCEPTANCE OF THE WORK BY THE OWNERS REPRESENTATIVE. MAKE
CORRECTIONS OR REPAIRS TO THE IRRIGATION AS REQUIRED, PRIOR TO COMPLETION OF THE MAINTENANCE PERIOD. REFER TO SPECIFICATIONS FOR THE TIME PERIOD.
27. ANY VARIANCE IN THE FIELD TO THE DRAWINGS AND SPECIFICATIONS WILL
REQUIRE THE SUBMITTAL OF A SHOP DRAWING FROM THE CONTRACTOR AND AN APPROVAL BY THE OWNERS REPRESENTATIVE. CHANGES BY THE
CONTRACTOR WITHOUT COSTCO'S APPROVAL SHALL BE PAID FOR BY THE CONTRACTOR.
28. THE IRRIGATION SYSTEM IS PROTECTED WITH A NORMALLY CLOSED MASTER VALVE. TO OPERATE A QUICK COUPLER VALVE AN OPEN STATION ON THE
CONTROLLER WILL REQUIRE ACTIVATION TO ALLOW WATER TO ENTER THE MAIN LINE.
"A Landscape Irrigation Audit is required. This Audit must be completed by a Certified Landscape Irrigation Auditor, not the designer or installer. The Audit must be submitted to the Building Department, with Certificate of Completion (Appendix C) as required by the Department of Water Resources, prior to scheduling a Final Inspection of the Water Efficient Landscape permit." LATERAL LINE:
SYMBOL
NOZZLE
GPMNUMBER DESCRIPTION
OPERATING RADIUS
(FEET)
OPERATING
PSI
IRRIGATION LEGEND
SLEEVING: 1120-CL. 200 PVC PLASTIC PIPE. COVER TO BE AS
INDICATED IN SPECIFICATIONS OR AS INDICATED ABOVE
FOR PIPE DEPTH OF COVER.
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH
SCHEDULE 40 PVC SOLVENT WELD FITTINGS.
18" COVER.
MAIN LINE: 2" THROUGHOUT
3/4" AND LARGER:
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH
SCHEDULE 40 PVC SOLVENT WELD FITTINGS.
12" COVER. (18 COVER UNDER PAVEMENT SECTION)
LATERAL LINE COVER FOR THE ROOF TO BE 6"-8" COVER
WTPRO3-C-
2W48-SWM
WeatherTRAK ET PRO3 2-WIRE 48 STATION CONTROLLER IN A
STAINLESS STEEL WALL MOUNTED ENCLOSURE.
WT2W-SVD-11 WEATHERTRAK DECODER (1 PER VALVE)
WT2W-LSP WEATHERTRAK SURGE ARRESTOR (1 EVERY 500 FEET ALONG MAIN) REFER TO DETAILS FOR INSTALLATION INSTRUCTIONS.
ROUTE TWO WIRE CABLE TO ALL REMOTE CONTROL VALVES. SIZE #14AWG WIRE WITH A JACKETED 2-CONDUCTOR. PREFERRED WIRE MAKE AND MODEL IS PAIGE ELECTRIC WIRE P7072D. ALL SPLICING SHALL BE MADE WITH 3-M DBR/Y-6 WATERPROOF SPLICE KITS OR APPROVED EQUAL. INSTALL 2 WIRE CABLE WITHIN 1.25" SCH 40 ELECTRICAL CONDUIT.
PULL BOXES SHALL BE LOCATED EVERY 200' NO SPLICES ARE ALLOWED BETWEEN VALVES. REFER TO DETAIL FOR INSTALLATION INSTRUCTIONS.
NOT SHOWN ON
PLANS
MV
WeatherTRAK 1" FLOW SENSOR (1-40 GPM)WT-FS-100-CSTFS
1 LA
CIM-5YA 5 YEAR EXTENSION OF WeatherTRAK Central.
T-YD-500-34 TORO DRIPLINE AIR RELIEF VALVE
WLT-0500-T NDS SCH 40 BALL VALVE OR APPROVED EQUAL
700-1-OMR-100 IRRITROL REMOTE CONTROL VALVE WITH PRESSURE REGULATOR (LOCATED IN EQUIPMENT ROOM)
700-1"/
HFR-100-075-40
IRRITROL 700 SERIES REMOTE CONTROL VALVE WITH HUNTER FILTER AND PRESSURE REGULATOR (40 PSI) AND A 1" FILTER (IN GROUND VALVES) T-580-A NIBCO BRASS BALL VALVE (LINE SIZE)
DRIPLINE REMOTE CONTROL VALVEPVC LATERAL
975XL-1.5" WILKINS REDUCED PRESSURE BACKFLOW ASSEMBLY
CONTROLLER AND STATION NUMBER
AREA (SQ. FT.)
FLOW (GPM)
REMOTE CONTROL VALVE SIZE (IN INCHES)
ASSOCIATED REMOTE CONTROL VALVE
WATER USE CLASSIFICATION OF ZONE
APPLICATION RATE (IN/HR) or DRIPLINE SPACING
570-DRIP-IND TORO POP-UP DRIPLINE INDICATOR WITH SIDE INLET.
DRIP ZONE:
TORO DL2000 SERIES DRIPLINE WITH DL2000 INSERT
FITTINGS, PART #RGP-212. TUBING TO BE INSTALLED 4"
BELOW GRADE IN A 12" O.C. GRID ACCORDING TO
DETAILS. SIZE EXHAUST HEADERS AS FOLLOWS: 1": 0-10
GPM, 1.25": 11-20 GPM. ALL EXHAUST HEADERS SHALL BE
1" SCH 40 PVC OR 1" SCH 40 FLEXIBLE PVC. USE SCH. 40
PVC SOLVENT WELD FITTINGS. EXTEND PVC HEADERS TO
THE ENDS OF ALL DRIP ZONES TO BALANCE FLOW IF
REQUIRED. SEE DETAILS FOR FURTHER INFORMATION.
DRIPLINE REMOTE CONTROL VALVE
APPROXIMATE CONNECTION POINT BETWEEN DRIPLINE
TUBING AND PVC SUPPLY WHEN DRIP ZONE IS LESS THAN
3 GPM AND NO PVC SUPPLY/EXHUST HEADERS ARE
NEEDED. REFER TO DRIPLINE TUBING CONNECTION
DETAIL FOR MORE INFORMATION.
SUPPLY
HEADER
EXHAUST
HEADER
DRIP ZONE
EXTENTS
PVC LATERAL
TORO POP-UP SPRAY
SPRINKLER (SHRUB)
8-10
10-12
12-151.2,0.6
0.75,0.37
1,0.5,0.23
570Z-12P-PRX-COM
O-T-12FP,12HP,12QP
570Z-12P-PRX-COM
O-T-10FP,10HP,10QP
570Z-12P-PRX-COM
O-T-15FP,15HP,15QP
DRIPLINE
LATERAL LINE:
3/4" AND LARGER:
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH SCHEDULE 40
PVC SOLVENT WELD FITTINGS. 12" COVER. (18" COVER
UNDER PAVING)
33DNP RAIN BIRD QUICK COUPLING VALVE
WT-MV-SNC WeatherTRAK BRASS MASTER VALVE (NORMALLY CLOSE)-(LINE SIZE)
TORO POP-UP SPRAY
SPRINKLER (SHRUB)
TORO POP-UP SPRAY
SPRINKLER (SHRUB)
30 30
30 0.066 30 TRICKLETORO BUBBLE (SHRUB)
MIN. 1 PER SHRUB (REFER TO
BUBBLER DETAIL FOR
QUANTITY OF BUBBLERS PER
SHRUB SIZE)
DB-04-PC-CV
WATER CONSERVATION STATEMENT
RUSSELL D MITCHELL AND ASSOCIATES, INC. (RMA) HAVE COMPLIED
WITH THE CRITERIA OF THE MODEL WATER EFFICIENT LANDSCAPE
ORDINANCE AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN.
JOSE L. CRUZ
IRRIGATION CONSULTATION-PROJECT MANGER
EZ-FLOW FERTILIZING SYSTEM WITH A 2" MAIN LINE CONNECTOR WITH BALL VALVE. CONTACT PHIL VANGENE WITH ANY QUESTION
CELL: 925-250-5885 EMAIL: [email protected]
EZ003-CX
CBV-2
ON GRADE DL2000
BROWNLINE DRIP RING FOR
TREES-SEE DETAIL
0.10 30 TRICKLET-PC-B-18-53-12
All drawings and written material appearing herein constitute Architect/Engineer and may not be duplicated, used or disclo SHEET L601
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
IRRIGATION LEGEND - PLUMBING & CIVIL
ELECTRICAL
CONDUIT:
SHOWN FOR REFERENCE ONLY, SEE ELECTRICAL
PLANS FOR ROUTING THROUGH STRUCTURE.
IRRIGATION POINT OF CONNECTION TO PEX PIPE AND
ELECTRICAL CONDUIT FOR COMMUNICATION WIRES
ROUTED THROUGH THE BUILDING AND STUBBED OUT INTO
PLANTERS WHERE SHOWN. WORK TO BE BY ELECTRICAL
AND PLUMBING CONTRACTORS.
SYMBOL DESCRIPTIONMODEL NUMBER
PEX PIPE. SHOWN FOR REFERENCE ONLY, SEE
PLUMBING PLANS FOR ROUTING THROUGH
STRUCTURE.
PEX
MAIN LINE:
THE CONTRACTOR ASSUMES FULL RESPONSIBILITY FOR REQUIRED REVISIONS.
2. LANDSCAPE AND IRRIGATION MAINTENANCE SCHEDULE, IRRIGATION AUDIT,
IRRIGATION SURVEY, AND IRRIGATION WATER USE ANALYSIS SHALL BE
SUBMITTED WITH THE CERTIFICATE OF COMPLETION IN COMPLIANCE WITH WATER EFFICIENT LANDSCAPE ORDINANCE AB 1881 PRIOR TO COUNTY ACCEPTANCE.
3. THE INTENT OF THIS IRRIGATION SYSTEM IS TO PROVIDE THE MINIMUM AMOUNT OF WATER REQUIRED TO SUSTAIN GOOD PLANT HEALTH.
4. THE LANDSCAPE CONTRACTOR SHALL SCHEDULE A POST CONSTRUCTION
MEETING WHICH INCLUDES REPRESENTATIVES OF THE IRRIGATION CONTROLLER
MANUFACTURER, THE MAINTENANCE CONTRACTOR, THE OWNE'R
REPRESENTATIVE AND THE IRRIGATION CONTRACTOR AT THE SITE FOR
INSTRUCTION ON THE PROPER PROGRAMMING AND OPERATION OF THE IRRIGATION CONTROLLER.
5. THE LANDSCAPE CONTRACTOR TO PROGRAM THE IRRIGATION
CONTROLLER TO PROVIDE THE MINIMUM AMOUNT OF WATER NEEDED TO SUSTAIN GOOD PLANT HEALTH. THIS INCLUDES MAKING ADJUSTMENTS TO THE
PROGRAM FOR SEASONAL WEATHER CHANGES, PLANT MATERIAL, WATER REQUIREMENTS, MOUNDS, SLOPES, SUN, SHADE AND WIND EXPOSURE.
6. IT IS THE RESPONSIBILITY OF A LICENSED ELECTRICAL CONTRACTOR TO PROVIDE 120 VOLT A.C. (2.5 AMP DEMAND TO CONTROLLER) ELECTRICAL SERVICE TO THE CONTROLLER LOCATION. IT IS THE RESPONSIBILITY OF THE IRRIGATION
CONTRACTOR TO COORDINATE THE ELECTRICAL SERVICE STUB-OUT TO THE CONTROLLER. PROVIDE PROPER GROUNDING PER CONTROLLER
MANUFACTURER'S INSTRUCTIONS AND IN ACCORDANCE WITH LOCAL CODES.
7. PROVIDE CONTROLLER WITH ITS OWN GROUND ROD. SEPARATE THE GROUND ROD BY A MINIMUM OF EIGHT FEET. THE GROUND ROD SHALL BE AN EIGHT FOOT LONG BY 5/8" DIAMETER U.L. APPROVED COPPER CLAD ROD. INSTALL NO MORE THAN 6" OF THE GROUND ROD ABOVE FINISH GRADE. CONNECT #6 GAUGE WIRE WITH A U.L. APPROVED GROUND ROD CLAMP TO ROD AND
BACK TO GROUND SCREW AT BASE OF CONTROLLER WITH APPROPRIATE CONNECTOR. MAKE THIS WIRE AS SHORT AS POSSIBLE, AVOIDING KINKS OR BENDING.
8. PROVIDE IRRIGATION CONTROLLER WITH ITS OWN INDEPENDENT LOW VOLTAGE COMMON GROUND WIRE.
9. INSTALL NEW BATTERIES IN THE IRRIGATION CONTROLLER TO RETAIN PROGRAM IN MEMORY DURING TEMPORARY POWER FAILURES. USE QUANTITY, TYPE AND SIZE REQUIRED AS PER MANUFACTURER'S INSTRUCTIONS.
10. FOR PROPER INSTALLATION OF THE 2-WIRE CABLE CONTRACTOR SHALL CONTACT CONTROLLER REPRESENTATIVE FOR A PRE-CONSTRUCTION MEETING.
11. IRRIGATION CONTROL WIRES: SOLID COPPER WITH U.L. APPROVAL FOR DIRECT BURIAL IN GROUND. SIZE #14AWG WIRE WITH A JACKETED 2-CONDUCTOR.
PREFERRED WIRE MAKE AND MODEL IS THE PAIGE IRRIGATION WIRE, SPEC P7350D (TORO). ALL SPLICING SHALL BE MADE WITH 3-M DBR/Y-6 WATERPROOF SPLICE KIT.
12. DECODER GROUNDING SHALL BE PROVIDED EVERY (500 FEET OR EVERY 8 DECODERS, WHICHEVER IS SMALLER. GROUND WITH A 8' GROUNDING ROD.
INCLUDE A SURGE ARRESTOR AT EACH GROUNDING LOCATION. A SPLIT BOLT
CONNECTION TO BE USED TO CONNECT THE SURGE DEVICE TO THE GROUND WIRE WITH A DBR/Y-6 WATERPROOF CONNECTOR.
13. SPLICING OF JACKETED 2-WIRE IS PERMITTED IN VALVE BOXES ONLY. LEAVE A 36" LONG COIL OF WIRE AT EACH SPLICE AND A 36" LONG EXPANSION LOOP EVERY 100 FEET ALONG WIRE RUN.
14. INSTALL BLACK PLASTIC VALVE BOXES AND LIDS WITH BOLT DOWN, NON HINGED COVER MARKED "IRRIGATION". BOX BODY SHALL HAVE KNOCK OUTS.
ACCEPTABLE VALVE BOX MANUFACTURER'S INCLUDE NDS, CARSON OR APPROVED EQUAL.
PRIOR TO CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE WATER
PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO THE OWNER'S REPRESENTATIVE.
19. IRRIGATION DEMAND: REFER TO PLANS.
20. PIPE SIZING SHOWN ON THE DRAWINGS IS TYPICAL. AS CHANGES IN LAYOUT
OCCUR DURING STAKING AND CONSTRUCTION THE SIZE MAY NEED TO BE ADJUSTED ACCORDINGLY.
21. PIPE THREAD SEALANT COMPOUND SHALL BE RECTOR SEAL #5.
22. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR CHANGES IN THE
IRRIGATION LAYOUT AND VALVE ZONING DUE TO VARIATIONS IN THE EXISTING SITE CONDITIONS SUCH AS EXPOSURE FROM BUILDINGS, TREES, ETC., AS WELL AS SLOPE AND SOIL CONDITIONS. THE CONTRACTOR SHALL NOTIFY
THE OWNER'S REPRESENTATIVE OF THE PROPOSED CHANGES PRIOR TO INSTALLATION FOR APPROVAL.
23. NOTIFY LOCAL JURISDICTIONS FOR INSPECTION AND TESTING OF BACKFLOW PREVENTION DEVICE. TESTING SHALL BE PERFORMED BY A LICENSED BACKFLOW TESTER AND TESTING SHALL BE DONE BEFORE WATER IS USED.
24. LOCATE AND PROTECT ALL UTILITES PRIOR TO CONSTRUCTION. DO NOT DAMAGE ANY UTITLIES, PAVING, OR STRUCTURES. CONTRACTOR TO MAKE ANY NECESSARY REPAIRS AT NO ADDITIONAL COST TO COSTCO.
25. REMOVE ALL IRRIGATION CONSTRUCTION DEBRIS FROM THE SITE AND LEAVE THE AREA CLEAN ACCEPTABLE TO THE OWNERS REPRESENTATIVE.
26. THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE SITE FOLLOWING ACCEPTANCE OF THE WORK BY THE OWNERS REPRESENTATIVE. MAKE
CORRECTIONS OR REPAIRS TO THE IRRIGATION AS REQUIRED, PRIOR TO COMPLETION OF THE MAINTENANCE PERIOD. REFER TO SPECIFICATIONS FOR THE TIME PERIOD.
27. ANY VARIANCE IN THE FIELD TO THE DRAWINGS AND SPECIFICATIONS WILL
REQUIRE THE SUBMITTAL OF A SHOP DRAWING FROM THE CONTRACTOR AND AN APPROVAL BY THE OWNERS REPRESENTATIVE. CHANGES BY THE
CONTRACTOR WITHOUT COSTCO'S APPROVAL SHALL BE PAID FOR BY THE CONTRACTOR.
28. THE IRRIGATION SYSTEM IS PROTECTED WITH A NORMALLY CLOSED MASTER VALVE. TO OPERATE A QUICK COUPLER VALVE AN OPEN STATION ON THE
CONTROLLER WILL REQUIRE ACTIVATION TO ALLOW WATER TO ENTER THE MAIN LINE.
"A Landscape Irrigation Audit is required. This Audit must be completed by a Certified Landscape Irrigation Auditor, not the designer or installer. The Audit must be submitted to the Building Department, with Certificate of Completion (Appendix C) as required by the Department of Water Resources, prior to scheduling a Final Inspection of the Water Efficient Landscape permit." PVC
S
H
PV
WATER CONSERVATION STATEMENT
RUSSELL D MITCHELL AND ASSOCIATES, INC. (RMA) HAVE COMPLIED
WITH THE CRITERIA OF THE MODEL WATER EFFICIENT LANDSCAPE
ORDINANCE AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN.
JOSE L. CRUZ
IRRIGATION CONSULTATION-PROJECT MANGER
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
08.05. 2022
DATE# REVISION LIST
ANDREA COCHRAN
LANDSCAPE ARCHITECTURE
2325 Third Street #210
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
1/16" = 1'-0"
IRRIGATION NOTES AND
LEGEND
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
IRRIGATION LEGEND - PLUMBING & CIVIL
ELECTRICAL
CONDUIT:
SHOWN FOR REFERENCE ONLY, SEE ELECTRICAL
PLANS FOR ROUTING THROUGH STRUCTURE.
IRRIGATION POINT OF CONNECTION TO PEX PIPE AND
ELECTRICAL CONDUIT FOR COMMUNICATION WIRES
ROUTED THROUGH THE BUILDING AND STUBBED OUT INTO
PLANTERS WHERE SHOWN. WORK TO BE BY ELECTRICAL
AND PLUMBING CONTRACTORS.
SYMBOL DESCRIPTIONMODEL NUMBER
PEX PIPE. SHOWN FOR REFERENCE ONLY, SEE
PLUMBING PLANS FOR ROUTING THROUGH
STRUCTURE.
PEX
MAIN LINE:
ND INDICATIVE OF THE
HER IRRIGATION
FOR GRAPHIC CLARITY
EAS. DUE TO THE SCALE
LL OFFSETS, FITTINGS,
REQUIRED. INVESTIGATE
G THE CONTRACT WORK
REA DIMENSIONAL
TH CONTRACT
INGLY BY
TCO REPRESENTATIVE
NOTIFY AND
PLICABLE CONTRACTORS
UIT OR SLEEVES
ND STRUCTURES BEFORE
ARE NOT PERFORMED,
REQUIRED REVISIONS.
, IRRIGATION AUDIT,
ALYSIS SHALL BE
COMPLIANCE WITH
OR TO COUNTY
E THE MINIMUM
ANT HEALTH.
T CONSTRUCTION
RRIGATION CONTROLLER
E OWNE'R
T THE SITE FOR
OPERATION OF THE
GATION
WATER NEEDED TO
G ADJUSTMENTS TO THE
MATERIAL, WATER
WIND EXPOSURE.
ONTRACTOR TO PROVIDE
CTRICAL SERVICE TO
OF THE IRRIGATION
E STUB-OUT TO THE
TROLLER
E WITH LOCAL CODES.
SEPARATE THE GROUND
SHALL BE AN EIGHT
R CLAD ROD. INSTALL
H GRADE. CONNECT #6
LAMP TO ROD AND
WITH APPROPRIATE
AVOIDING KINKS OR
EPENDENT LOW
ER TO RETAIN PROGRAM
E QUANTITY, TYPE AND
S.
TRACTOR SHALL
ONSTRUCTION MEETING.
APPROVAL FOR DIRECT
ETED 2-CONDUCTOR.
ATION WIRE, SPEC
M DBR/Y-6
0 FEET OR EVERY 8
8' GROUNDING ROD.
OCATION. A SPLIT BOLT
VICE TO THE GROUND
BOXES ONLY. LEAVE A
ONG EXPANSION LOOP
OLT DOWN, NON
ALL HAVE KNOCK OUTS.
DS, CARSON OR
15. INSTALL REMOTE CONTROL VALVE BOXES 12" FROM WALK, CURB, BUILDING OR LANDSCAPE FEATURE. AT MULTIPLE VALVE BOX GROUPS, INSTALL EACH BOX
AN EQUAL DISTANCE FROM THE WALK, CURB, BUILDING OR LANDSCAPE FEATURE AND PROVIDE 12" BETWEEN BOX TOPS. ALIGN THE SHORT SIDE OF
RECTANGULAR VALVE BOXES PARALLEL TO WALK, CURB, BUILDING OR LANDSCAPE FEATURE.
16. LOCATE BUBBLERS ON UPHILL SIDE OF TREE.
17. INSTALL A HUNTER HCV SERIES, KBI CV SERIES, OR APPROVED EQUAL SPRING
LOADED CHECK VALVE IN SPRINKLER RISER ASSEMBLIES WHERE LOW OUTLET DRAINAGE WILL CAUSE EROSION AND/OR EXCESS WATER.
18. THE IRRIGATION SYSTEM DESIGN IS BASED ON THE MINIMUM OPERATING PRESSURE SHOWN ON THE IRRIGATION DRAWINGS. VERIFY WATER PRESSURE PRIOR TO CONSTRUCTION. REPORT ANY DIFFERENCE BETWEEN THE WATER
PRESSURE INDICATED ON THE DRAWINGS AND THE ACTUAL PRESSURE READING AT THE IRRIGATION POINT OF CONNECTION TO THE OWNER'S REPRESENTATIVE.
19. IRRIGATION DEMAND: REFER TO PLANS.
20. PIPE SIZING SHOWN ON THE DRAWINGS IS TYPICAL. AS CHANGES IN LAYOUT
OCCUR DURING STAKING AND CONSTRUCTION THE SIZE MAY NEED TO BE ADJUSTED ACCORDINGLY.
21. PIPE THREAD SEALANT COMPOUND SHALL BE RECTOR SEAL #5.
22. THE LANDSCAPE CONTRACTOR SHALL BE RESPONSIBLE FOR CHANGES IN THE
IRRIGATION LAYOUT AND VALVE ZONING DUE TO VARIATIONS IN THE EXISTING SITE CONDITIONS SUCH AS EXPOSURE FROM BUILDINGS, TREES, ETC., AS WELL AS SLOPE AND SOIL CONDITIONS. THE CONTRACTOR SHALL NOTIFY
THE OWNER'S REPRESENTATIVE OF THE PROPOSED CHANGES PRIOR TO INSTALLATION FOR APPROVAL.
23. NOTIFY LOCAL JURISDICTIONS FOR INSPECTION AND TESTING OF BACKFLOW PREVENTION DEVICE. TESTING SHALL BE PERFORMED BY A LICENSED BACKFLOW TESTER AND TESTING SHALL BE DONE BEFORE WATER IS USED.
24. LOCATE AND PROTECT ALL UTILITES PRIOR TO CONSTRUCTION. DO NOT DAMAGE ANY UTITLIES, PAVING, OR STRUCTURES. CONTRACTOR TO MAKE ANY NECESSARY REPAIRS AT NO ADDITIONAL COST TO COSTCO.
25. REMOVE ALL IRRIGATION CONSTRUCTION DEBRIS FROM THE SITE AND LEAVE THE AREA CLEAN ACCEPTABLE TO THE OWNERS REPRESENTATIVE.
26. THE LANDSCAPE CONTRACTOR SHALL MAINTAIN THE SITE FOLLOWING ACCEPTANCE OF THE WORK BY THE OWNERS REPRESENTATIVE. MAKE
CORRECTIONS OR REPAIRS TO THE IRRIGATION AS REQUIRED, PRIOR TO COMPLETION OF THE MAINTENANCE PERIOD. REFER TO SPECIFICATIONS FOR THE TIME PERIOD.
27. ANY VARIANCE IN THE FIELD TO THE DRAWINGS AND SPECIFICATIONS WILL
REQUIRE THE SUBMITTAL OF A SHOP DRAWING FROM THE CONTRACTOR AND AN APPROVAL BY THE OWNERS REPRESENTATIVE. CHANGES BY THE
CONTRACTOR WITHOUT COSTCO'S APPROVAL SHALL BE PAID FOR BY THE CONTRACTOR.
28. THE IRRIGATION SYSTEM IS PROTECTED WITH A NORMALLY CLOSED MASTER VALVE. TO OPERATE A QUICK COUPLER VALVE AN OPEN STATION ON THE
CONTROLLER WILL REQUIRE ACTIVATION TO ALLOW WATER TO ENTER THE MAIN LINE.
"A Landscape Irrigation Audit is required. This Audit must be completed by a Certified Landscape Irrigation Auditor, not the designer or installer. The Audit must be submitted to the Building Department, with Certificate of Completion (Appendix C) as required by the Department of Water Resources, prior to scheduling a Final Inspection of the Water Efficient Landscape permit." LATERAL LINE:
SYMBOL
NOZZLE
GPMNUMBER DESCRIPTION
OPERATING RADIUS
(FEET)
OPERATING
PSI
IRRIGATION LEGEND
SLEEVING: 1120-CL. 200 PVC PLASTIC PIPE. COVER TO BE AS
INDICATED IN SPECIFICATIONS OR AS INDICATED ABOVE
FOR PIPE DEPTH OF COVER.
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH
SCHEDULE 40 PVC SOLVENT WELD FITTINGS.
18" COVER.
MAIN LINE: 2" THROUGHOUT
3/4" AND LARGER:
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH
SCHEDULE 40 PVC SOLVENT WELD FITTINGS.
12" COVER. (18 COVER UNDER PAVEMENT SECTION)
LATERAL LINE COVER FOR THE ROOF TO BE 6"-8" COVER
WTPRO3-C-
2W48-SWM
WeatherTRAK ET PRO3 2-WIRE 48 STATION CONTROLLER IN A
STAINLESS STEEL WALL MOUNTED ENCLOSURE.
WT2W-SVD-11 WEATHERTRAK DECODER (1 PER VALVE)
WT2W-LSP WEATHERTRAK SURGE ARRESTOR (1 EVERY 500 FEET ALONG MAIN) REFER TO DETAILS FOR INSTALLATION INSTRUCTIONS.
ROUTE TWO WIRE CABLE TO ALL REMOTE CONTROL VALVES. SIZE #14AWG WIRE WITH A JACKETED 2-CONDUCTOR. PREFERRED WIRE MAKE AND MODEL IS PAIGE ELECTRIC WIRE P7072D. ALL SPLICING SHALL BE MADE WITH 3-M DBR/Y-6 WATERPROOF SPLICE KITS OR APPROVED EQUAL. INSTALL 2 WIRE CABLE WITHIN 1.25" SCH 40 ELECTRICAL CONDUIT.
PULL BOXES SHALL BE LOCATED EVERY 200' NO SPLICES ARE ALLOWED BETWEEN VALVES. REFER TO DETAIL FOR INSTALLATION INSTRUCTIONS.
NOT SHOWN ON
PLANS
MV
WeatherTRAK 1" FLOW SENSOR (1-40 GPM)WT-FS-100-CSTFS
1 LA
CIM-5YA 5 YEAR EXTENSION OF WeatherTRAK Central.
T-YD-500-34 TORO DRIPLINE AIR RELIEF VALVE
WLT-0500-T NDS SCH 40 BALL VALVE OR APPROVED EQUAL
700-1-OMR-100 IRRITROL REMOTE CONTROL VALVE WITH PRESSURE REGULATOR (LOCATED IN EQUIPMENT ROOM)
700-1"/
HFR-100-075-40
IRRITROL 700 SERIES REMOTE CONTROL VALVE WITH HUNTER FILTER AND PRESSURE REGULATOR (40 PSI) AND A 1" FILTER (IN GROUND VALVES) T-580-A NIBCO BRASS BALL VALVE (LINE SIZE)
DRIPLINE REMOTE CONTROL VALVEPVC LATERAL
975XL-1.5" WILKINS REDUCED PRESSURE BACKFLOW ASSEMBLY
CONTROLLER AND STATION NUMBER
AREA (SQ. FT.)
FLOW (GPM)
REMOTE CONTROL VALVE SIZE (IN INCHES)
ASSOCIATED REMOTE CONTROL VALVE
WATER USE CLASSIFICATION OF ZONE
APPLICATION RATE (IN/HR) or DRIPLINE SPACING
570-DRIP-IND TORO POP-UP DRIPLINE INDICATOR WITH SIDE INLET.
DRIP ZONE:
TORO DL2000 SERIES DRIPLINE WITH DL2000 INSERT
FITTINGS, PART #RGP-212. TUBING TO BE INSTALLED 4"
BELOW GRADE IN A 12" O.C. GRID ACCORDING TO
DETAILS. SIZE EXHAUST HEADERS AS FOLLOWS: 1": 0-10
GPM, 1.25": 11-20 GPM. ALL EXHAUST HEADERS SHALL BE
1" SCH 40 PVC OR 1" SCH 40 FLEXIBLE PVC. USE SCH. 40
PVC SOLVENT WELD FITTINGS. EXTEND PVC HEADERS TO
THE ENDS OF ALL DRIP ZONES TO BALANCE FLOW IF
REQUIRED. SEE DETAILS FOR FURTHER INFORMATION.
DRIPLINE REMOTE CONTROL VALVE
APPROXIMATE CONNECTION POINT BETWEEN DRIPLINE
TUBING AND PVC SUPPLY WHEN DRIP ZONE IS LESS THAN
3 GPM AND NO PVC SUPPLY/EXHUST HEADERS ARE
NEEDED. REFER TO DRIPLINE TUBING CONNECTION
DETAIL FOR MORE INFORMATION.
SUPPLY
HEADER
EXHAUST
HEADER
DRIP ZONE
EXTENTS
PVC LATERAL
TORO POP-UP SPRAY
SPRINKLER (SHRUB)
8-10
10-12
12-151.2,0.6
0.75,0.37
1,0.5,0.23
570Z-12P-PRX-COM
O-T-12FP,12HP,12QP
570Z-12P-PRX-COM
O-T-10FP,10HP,10QP
570Z-12P-PRX-COM
O-T-15FP,15HP,15QP
DRIPLINE
LATERAL LINE:
3/4" AND LARGER:
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH SCHEDULE 40
PVC SOLVENT WELD FITTINGS. 12" COVER. (18" COVER
UNDER PAVING)
33DNP RAIN BIRD QUICK COUPLING VALVE
WT-MV-SNC WeatherTRAK BRASS MASTER VALVE (NORMALLY CLOSE)-(LINE SIZE)
TORO POP-UP SPRAY
SPRINKLER (SHRUB)
TORO POP-UP SPRAY
SPRINKLER (SHRUB)
30 30
30 0.066 30 TRICKLETORO BUBBLE (SHRUB)
MIN. 1 PER SHRUB (REFER TO
BUBBLER DETAIL FOR
QUANTITY OF BUBBLERS PER
SHRUB SIZE)
DB-04-PC-CV
WATER CONSERVATION STATEMENT
RUSSELL D MITCHELL AND ASSOCIATES, INC. (RMA) HAVE COMPLIED
WITH THE CRITERIA OF THE MODEL WATER EFFICIENT LANDSCAPE
ORDINANCE AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN.
JOSE L. CRUZ
IRRIGATION CONSULTATION-PROJECT MANGER
EZ-FLOW FERTILIZING SYSTEM WITH A 2" MAIN LINE CONNECTOR WITH BALL VALVE. CONTACT PHIL VANGENE WITH ANY QUESTION
CELL: 925-250-5885 EMAIL: [email protected]
EZ003-CX
CBV-2
ON GRADE DL2000
BROWNLINE DRIP RING FOR
TREES-SEE DETAIL
0.10 30 TRICKLET-PC-B-18-53-12
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch SHEET L601
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
IRRIGATION LEGEND - PLUMBING & CIVIL
ELECTRICAL
CONDUIT:
SHOWN FOR REFERENCE ONLY, SEE ELECTRICAL
PLANS FOR ROUTING THROUGH STRUCTURE.
IRRIGATION POINT OF CONNECTION TO PEX PIPE AND
ELECTRICAL CONDUIT FOR COMMUNICATION WIRES
ROUTED THROUGH THE BUILDING AND STUBBED OUT INTO
PLANTERS WHERE SHOWN. WORK TO BE BY ELECTRICAL
AND PLUMBING CONTRACTORS.
SYMBOL DESCRIPTIONMODEL NUMBER
PEX PIPE. SHOWN FOR REFERENCE ONLY, SEE
PLUMBING PLANS FOR ROUTING THROUGH
STRUCTURE.
PEX
MAIN LINE:
CONNECTOR. MAKE THIS WIRE AS SHORT AS POSSIBLE, AVOIDING KINKS OR BENDING.
8. PROVIDE IRRIGATION CONTROLLER WITH ITS OWN INDEPENDENT LOW VOLTAGE COMMON GROUND WIRE.
9. INSTALL NEW BATTERIES IN THE IRRIGATION CONTROLLER TO RETAIN PROGRAM IN MEMORY DURING TEMPORARY POWER FAILURES. USE QUANTITY, TYPE AND SIZE REQUIRED AS PER MANUFACTURER'S INSTRUCTIONS.
10. FOR PROPER INSTALLATION OF THE 2-WIRE CABLE CONTRACTOR SHALL CONTACT CONTROLLER REPRESENTATIVE FOR A PRE-CONSTRUCTION MEETING.
11. IRRIGATION CONTROL WIRES: SOLID COPPER WITH U.L. APPROVAL FOR DIRECT BURIAL IN GROUND. SIZE #14AWG WIRE WITH A JACKETED 2-CONDUCTOR.
PREFERRED WIRE MAKE AND MODEL IS THE PAIGE IRRIGATION WIRE, SPEC P7350D (TORO). ALL SPLICING SHALL BE MADE WITH 3-M DBR/Y-6 WATERPROOF SPLICE KIT.
12. DECODER GROUNDING SHALL BE PROVIDED EVERY (500 FEET OR EVERY 8 DECODERS, WHICHEVER IS SMALLER. GROUND WITH A 8' GROUNDING ROD.
INCLUDE A SURGE ARRESTOR AT EACH GROUNDING LOCATION. A SPLIT BOLT
CONNECTION TO BE USED TO CONNECT THE SURGE DEVICE TO THE GROUND WIRE WITH A DBR/Y-6 WATERPROOF CONNECTOR.
13. SPLICING OF JACKETED 2-WIRE IS PERMITTED IN VALVE BOXES ONLY. LEAVE A 36" LONG COIL OF WIRE AT EACH SPLICE AND A 36" LONG EXPANSION LOOP EVERY 100 FEET ALONG WIRE RUN.
14. INSTALL BLACK PLASTIC VALVE BOXES AND LIDS WITH BOLT DOWN, NON HINGED COVER MARKED "IRRIGATION". BOX BODY SHALL HAVE KNOCK OUTS.
ACCEPTABLE VALVE BOX MANUFACTURER'S INCLUDE NDS, CARSON OR APPROVED EQUAL.
REQUIRE THE SUBMITTAL OF A SHOP DRAWING FROM THE CONTRACTOR AND AN APPROVAL BY THE OWNERS REPRESENTATIVE. CHANGES BY THE
CONTRACTOR WITHOUT COSTCO'S APPROVAL SHALL BE PAID FOR BY THE CONTRACTOR.
28. THE IRRIGATION SYSTEM IS PROTECTED WITH A NORMALLY CLOSED MASTER VALVE. TO OPERATE A QUICK COUPLER VALVE AN OPEN STATION ON THE
CONTROLLER WILL REQUIRE ACTIVATION TO ALLOW WATER TO ENTER THE MAIN LINE.
"A Landscape Irrigation Audit is required. This Audit must be completed by a Certified Landscape Irrigation Auditor, not the designer or installer. The Audit must be submitted to the Building Department, with Certificate of Completion (Appendix C) as required by the Department of Water Resources, prior to scheduling a Final Inspection of the Water Efficient Landscape permit." LATERAL LINE:
SLEEVING: 1120-CL. 200 PVC PLASTIC PIPE. COVER TO BE AS
INDICATED IN SPECIFICATIONS OR AS INDICATED ABOVE
FOR PIPE DEPTH OF COVER.
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH
SCHEDULE 40 PVC SOLVENT WELD FITTINGS.
18" COVER.
MAIN LINE: 2" THROUGHOUT
3/4" AND LARGER:
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH
SCHEDULE 40 PVC SOLVENT WELD FITTINGS.
12" COVER. (18 COVER UNDER PAVEMENT SECTION)
LATERAL LINE COVER FOR THE ROOF TO BE 6"-8" COVER
DRIPLINE REMOTE CONTROL VALVEPVC LATERAL
CONTROLLER AND STATION NUMBER
AREA (SQ. FT.)
FLOW (GPM)
REMOTE CONTROL VALVE SIZE (IN INCHES)
ASSOCIATED REMOTE CONTROL VALVE
WATER USE CLASSIFICATION OF ZONE
APPLICATION RATE (IN/HR) or DRIPLINE SPACING
DRIP ZONE:
TORO DL2000 SERIES DRIPLINE WITH DL2000 INSERT
FITTINGS, PART #RGP-212. TUBING TO BE INSTALLED 4"
BELOW GRADE IN A 12" O.C. GRID ACCORDING TO
DETAILS. SIZE EXHAUST HEADERS AS FOLLOWS: 1": 0-10
GPM, 1.25": 11-20 GPM. ALL EXHAUST HEADERS SHALL BE
1" SCH 40 PVC OR 1" SCH 40 FLEXIBLE PVC. USE SCH. 40
PVC SOLVENT WELD FITTINGS. EXTEND PVC HEADERS TO
THE ENDS OF ALL DRIP ZONES TO BALANCE FLOW IF
REQUIRED. SEE DETAILS FOR FURTHER INFORMATION.
DRIPLINE REMOTE CONTROL VALVE
APPROXIMATE CONNECTION POINT BETWEEN DRIPLINE
TUBING AND PVC SUPPLY WHEN DRIP ZONE IS LESS THAN
3 GPM AND NO PVC SUPPLY/EXHUST HEADERS ARE
NEEDED. REFER TO DRIPLINE TUBING CONNECTION
DETAIL FOR MORE INFORMATION.
SUPPLY
HEADER
EXHAUST
HEADER
DRIP ZONE
EXTENTS
PVC LATERAL
DRIPLINE
LATERAL LINE:
3/4" AND LARGER:
1120-SCHEDULE 40 PVC PLASTIC PIPE WITH SCHEDULE 40
PVC SOLVENT WELD FITTINGS. 12" COVER. (18" COVER
UNDER PAVING)
WATER CONSERVATION STATEMENT
RUSSELL D MITCHELL AND ASSOCIATES, INC. (RMA) HAVE COMPLIED
WITH THE CRITERIA OF THE MODEL WATER EFFICIENT LANDSCAPE
ORDINANCE AND APPLIED THEM ACCORDINGLY FOR THE EFFICIENT USE OF WATER IN THE LANDSCAPE DESIGN PLAN.
JOSE L. CRUZ
IRRIGATION CONSULTATION-PROJECT MANGER
BALL VALVE. CONTACT PHIL VANGENE WITH ANY QUESTION
CELL: 925-250-5885 EMAIL: [email protected]
CBV-2
LANDSCAPE - IRRIGATION
Attachment 6
65 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the If this drawing is not 24"x36", then the drawing has been revised from its original size.
KEYPLAN
-
08.05. 2022
DATE# REVISION LIST
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
L505
1/16" = 1'-0"
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
6"typ. RED BLK
SCALE: NONE
DET: --------
3 INSTALLATION DETAIL - MASTER VALVE/FLOW SENSOR
VALVE CONTROL WIRE: SOLID COPPER, DIRECT
BURIAL WIRE. POSITIVE: DIFFERENT COLOR FROM
RCV WIRES 12-1, NEURTAL: WHITE 14-1. PROVIDE
WATERPROOF SPLICES AND 36" OF EXCESS WIRE
IN A 1" DIAMETER COIL. RUN IN THE SAME
CONDUIT WITH FLOW SENSOR WIRE.
FINISH
GRADE
TO CONTROLLER
MASTER VALVE
PEA GRAVEL-4" DEEP BELOW VALVE (NO
SOIL IN VALVE BOX), TYP.
BRICK-ONE @EACH CORNER, TYP.
PVC MAIN LINE
TO CONTROLLER
18 GAUGE AWG DIRECT BURRIAL WIRE. FLOW
SENSOR WIRE MUST BE RUN IN 1.5" PVC
CONDUIT FROM FLOW SENSOR TO
CONTROLLER ENCLOSURE.
FLOW SENSOR MUST BE INSTALLED WITH INSERT
(TOP) POSITIONED VERTICALLY AND BODY (TEE)
POSITIONED HORIZONTALLY.
SCH. 80 REDUCING
COUPLING, TYP.
FLOW
SENSOR
10 PIPE DIAMETERS
DIMENSION
'A'
5 PIPE DIAMETERS
DIMENSION
'B'
NO VALVES,
REDUCERS, OR
ELBOWS IN THIS
AREA
VALVE
BOX
VALVE
BOX
SCH. 40 PVC (TYP).
VALVE I.D. TAG
(CONTROLLER AND
STATION NUMBER)
AND PURPLE
RECYCLED WATER
WARNING TAG (2
TAGS TOTAL)
VALVE I.D. TAG
(CONTROLLER AND
STATION NUMBER)
AND PURPLE
RECYCLED WATER
WARNING TAG (2
TAGS TOTAL)
PVC
MAIN LINE.
2.5"
FRONT VIEWSIDE VIEW
1 2
3 4
5 MOUNTING BRACKETS (STANDARD WITH ENCLOSURE) TO BE SET INTO CONCRETE PAD.
PROVIDE LOCKING TAB TO ACCEPT PADLOCK PER MANUFACTURER'S INSTRUCTION. 6" [150mm] THICK CONCRETE PAD FOR ENCLOSURE SUPPORT TO EXTEND 6" [150mm] BEYOND ENCLOSURE ON ALL SIDES. CONCRETE TO HAVE MEDIUM BROOM FINISH.
FINISH GRADE
SET PAD 1/2" [13MM] ABOVE FINISH GRADE
STAINLESS STEEL ENCLOSURE TO COMPLETELY ENCLOSE DEVICE
5 1
2 3
4 [65mm]
SCALE: NONE
2 BACKFLOW ASSEMBLY ENCLOSURE
SCALE: NONE
1 REDUCED PRESSURE BACKFLOW ASSEMBLY
INSTALL A FREEZE PREVENTATIVE BLANKET AROUND BACKFLOW ASSEMBLY. BLANKET SHALL BE GREEN.
NIPPLES AND FITTINGS TO BE SAME IPT SIZE AS BACKFLOW ASSEMBLY.
DO NOT SOLDER CONNECT FITTINGS WHILE THREADED INTO BACKFLOW ASSEMBLY.
THIS MAY CAUSE DAMAGE TO DEVICE.
1 3
4 5
6 7
8 PROVIDE A STAINLESS STEEL ENCLOSURE TO COMPLETELY ENCLOSE DEVICE. INSTALL ENCLOSURE TO CONCRETE BASE AS DIRECTED BY MANUFACTURER.
REDUCED PRESSURE BACKFLOW
ASSEMBLY.
WROUGHT COPPER MALE ADAPTER-2
TOTAL (SOLDER x THREAD CONNECTION).
COPPER TYPE "K" PIPE (LENGTH
AS REQUIRED).
WROUGHT COPPER 90° ELBOW-2 TOTAL
(SOLDER x THREAD CONNECTION).
PVC MAIN LINE TO POINT OF
CONNECTION.
BUSH AS NECESSARY FOR SIZE
TRANSITION.
REFER TO IRRIGATION LEGEND.
PVC SLEEVE BOTH SIDES.
FINISH GRADE.
CONCRETE PAD-SEE ENCLOSURE DETAIL.
CONCRETE SUPPORT BLOCK.
SCHEDULE 40 PVC MALE ADAPTER-2
TOTAL.
9 11
12 13
14 PVC MAIN LINE TO IRRIGATION SYSTEM.
NOTES:
1. 2.
3. 4.
10 FLOW
1 10
11 12
987 14
13 3
4 5
6 2
YB "Y" STRAINER SYSTEM (AS
REQUIRED).
2 12"[300mm]
SCALE: NONE
7 WEATHERPROOF WIRE SPLICE ASSEMBLY
1 2
3 4 5
INSTRUCTIONS:
STRIP WIRES APPROXIMATELY 1/2" (13 mm) TO EXPOSE WIRE.
TWIST CONNECTOR AROUND WIRES CLOCKWISE UNTIL HAND
TIGHT, DO NOT OVERTIGHTEN.
INSERT WIRE ASSEMBLY INTO PLASTIC TUBE UNTIL WIRE
CONNECTOR SNAPS PAST LIP IN BOTTOM OF TUBE.
PLACE WIRES WHICH EXIT TUBE IN WIRE EXIT HOLES AND
CLOSE CAP UNTIL IT SNAPS.
INSPECT FINAL SPLICE ASSEMBLY TO BE SECURE AND
FINISHED.
1. 2.
3. 4.
5. INTERIOR WALL
120 VOLT LOCKABLE WEATHERPROOF ON/OFF SWITCH PROVIDED UNDER IRRIGATION CONTRACT.
120 VOLT SERVICE TO CONTROLLER LOCATION PROVIDED BY CONTRACTOR.
IRRIGATION CONTROLLER.
120 VOLT SERVICE IN RIGID STEEL CONDUIT.
FINISH FLOOR.
5 6
4 3
2 1
1 4
3 2 5
6 50" MAX.
SCALE: NONE
6 CONTROLLER - INTERIOR WALL MOUNTED
LOW VOLTAGE WIRE IN SCHEDULE 40 PVC CONDUIT. 2-WIREBRASS BALL VALVE COMMON BRICK, TWO TOTAL-180° APART
10" ROUND X 12" DEEP PLASTIC VALVE BOX
4"
1/2"
REFER TOIRRIGATION
NOTE:
BRASS NIPPLES WILL ALLOW
FOR A 10 FPS FLOW THROUGH VALVE.
LEGEND
PEA GRAVEL (NO SOIL IN VALVE BOX)
SCALE: NONE
1 2
3 FINISH GRADE
4 5
6 7
1 2
3 5
7 4 BALL VALVE-BRASS
PVC MAIN LINE TO BACKFLOW
6 4
MALE ADAPTER. REFER TO LEGEND FOR FITTING TYPE.
EZ-FLO FERTILIZING SYSTEM MODEL NUMBER -
EZ001-CX 1.5 GALLON CAPACITY
1 PROPORTIONING CAP WITH FEED ADJUSTMENT KNOB.
NOTE:
ITEMS 3, 4, 5, 6, 7 AND 8 ARE INCLUDED WITH THE EZ-FLO SYSTEM. ITEM 11 IS PURCHASED SEPARATELY.
SCALE: NONE
FINISHED GRADE.
VALVE BOX & COVER 17"L X 12"D X 12"W.
EZ-FLO SHUT OFF VALVES.
1 2
3 4
5 EZ-FLO MODEL EZ001-CX FERTILIZING SYSTEM- 13" X 8"D X 11"H. 6 FERTILIZER OUT-CONNECT CLEAR TUBE TO GREEN CONNECTIONS ON PROPORTIONING CAP AND COUPLING.
7 WATER IN-CONNECT BLACK TUBE TO BLUE CONNECTIONS ON PROPORTIONING CAP AND COUPLING.
8 1/4" TUBING CLAMP-BOTH THE GREEN AND BLUE COUPLING TUBING CONNECTIONS. 9 BRICK-1 EACH CORNER.
10 PVC MAIN LINE TO VALVE MANIFOLD.
11 EZ COUPLING CONNECTOR-INSTALL ACCORDING TO WATER DIRECTION FLOW ARROW.
12 PEA GRAVEL (1 CU. FT.)
13 PVC MAIN LINE FROM BACK FLOW PREVENTER.
2 3
4 4 5
6 7
8 9 10 11 12 13
5 NOTES & DETAILS - L505
SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 7
9 2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
5 7
DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
LANDSCAPE - IRRIGATION
Attachment 6
66 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
SCALE: NONE
ON STRUCTURE UPPER LEVEL STUB-OUT
WITH BRONZE BALL VALVE1
1 1
2 3
4 8
7 BRONZE BALL VALVE.
6 10
9 PEX 90° ELBOW.
PEX MALE ADAPTER.
CONDUIT FOR CONTROL WIRES
THROUGH STRUCTURE PROVIDED BY
ELECTRICAL CONTRACTOR.
WATERPROOF ALL PENETRATIONS
PEX PIPE THROUGH STRUCTURE
PROVIDED BY PLUMBING
CONTRACTOR. WATERPROOF ALL
PENETRATIONS. 10
2 4
7 9
6 SCH 40 PVC MALE ADAPTER.
3 SLOPED ROOF BELOW PEDESTAL
SYSTEM
5 5
PVC MAIN LINE TO REMOTE
CONTROL VALVES.
ROOF DECK PAVERS8
11 11 10" ROUND PLASTIC VALVE BOX.
CUT BOX TO FIT BELOW
PEDESTAL PAVER SYSTEM
TWO-WIRE CABLE OR CONTROL WIRES
SCALE: NONE
3 1
2 CARSON 1220 BLACK
RECTANGULAR PLASTIC VALVE
BOX WITH LID. INSTALL PER
REMOTE CONTROL VALVE DETAIL.
15 18
SCHEDULE 80 PVC THREADED
FEMALE COUPLING TO SERVICE QCV.
IF NO QCV INSTALL A DURA 1" CAP
(PART #348-010)
SCHEDULE 80 PVC NIPPLE (LENGTH AS
REQUIRED).
19 20
SCHEDULE 80 PVC 90° ELBOW (TxT).
SCHEDULE 80 PVC NIPPLE (LENGTH AS
REQUIRED).
DURA 1"x1" THREADED
ADAPTER (PART #08303) 3
TOTAL.
9 13
14DRIP REMOTE CONTROL VALVE. REFER
TO LEGEND FOR MODEL.
SCHEDULE 40 PVC LATERAL TO DRIP
IRRIGATION
10 FILTER. REFER TO LEGEND FOR
MODEL.
5 NDS 1"LO-TORQ BALL VALVE
THREADED (PART #LT-1000-T)
DURA 1" SLIP X 1" SWIVEL (PART
#329-011) 4 TOTAL.
SCH 40 PVC 90° ELBOW (SxS) FROM
PVC MAIN LINE BELOW.
SCH 40 PVC PIPE. LENGTH AS
REQUIRED.
3 SCH 80 PVC MALE ADAPTER.
4 7
8 DURA 1" MULTI-PORT MANIFOLD (PART
#301-010-2)
11 40 PSI REGULATOR. REFER TO LEGEND
FOR MODEL.
12 DURA 1" x 3/4" MALE ADAPTER (PART
#08303-131). ONLY REQUIRED WITH 3/4"
OUTLET REGULATORS. USE 1"x1" DURA
THREAD ADAPTER ON 1" REGULATORS
16 BUBBLER OR SPRINKLER REMOTE
CONTROL VALVE. REFER TO LEGEND
FOR MODEL.
17 SCHEDULE 40 PVC LATERAL TO
BUBBLER OR SPRAY IRRIGATION.
DURA 1" MIPT x 1" SWIVEL 90° (PART
#306-009)
6 7 8 15 19
20 17
11 18
16 10
5 3
1 2
9 12
13 14
4 6
2.5"MIN.
22 QUICK COUPLING VALVE. INSTALL PER
DETAIL.
10" ROUND BOX. INSTALL PER DETAIL.
21 21
22 TWO REMOTE VALVE MANIFOLD DETAIL WITH QUICK COUPLING VALVE SCALE: NONE
4 1
2 CARSON 1220 BLACK
RECTANGULAR PLASTIC VALVE
BOX WITH LID. INSTALL PER
REMOTE CONTROL VALVE DETAIL.
15 16
SCHEDULE 80 PVC THREADED FEMALE
COUPLING TO SERVICE QCV. IF NO
QCV INSTALL A DURA 1" CAP (PART
#348-010)
SCHEDULE 80 PVC NIPPLE (LENGTH AS
REQUIRED).
17 18
SCHEDULE 80 PVC 90° ELBOW (TxT).
SCHEDULE 80 PVC NIPPLE (LENGTH AS
REQUIRED).
DURA 1"x1" THREADED
ADAPTER (PART #08303) 3
TOTAL.
9 13
14DRIP REMOTE CONTROL VALVE. REFER
TO LEGEND FOR MODEL.
SCHEDULE 40 PVC LATERAL TO DRIP
IRRIGATION
10 FILTER. REFER TO LEGEND FOR
MODEL.
5 NDS 1"LO-TORQ BALL VALVE
THREADED (PART #LT-1000-T)
DURA 1" SLIP X 1" SWIVEL (PART
#329-011) 4 TOTAL.
SCH 40 PVC 90° ELBOW (SxS) FROM
PVC MAIN LINE BELOW.
SCH 40 PVC PIPE. LENGTH AS
REQUIRED.
3 SCH 80 PVC MALE ADAPTER.
4 7
8 DURA 1" MULTI-PORT MANIFOLD (PART
#301-010-2)
11 40 PSI REGULATOR. REFER TO LEGEND
FOR MODEL.
12 DURA 1" x 3/4" MALE ADAPTER (PART
#08303-131). ONLY REQUIRED WITH 3/4"
OUTLET REGULATORS. USE 1"x1" DURA
THREAD ADAPTER ON 1" REGULATORSDURA 1" MIPT x 1" SWIVEL 90° (PART #306-009)
6 7 8 15 17
18 11
16 10
5 3
1 2
9 12
13 14
4 6
2.5"MIN.
20 QUICK COUPLING VALVE. INSTALL PER
DETAIL.
10" ROUND BOX. INSTALL PER DETAIL.
19 19
20 REMOTE VALVE MANIFOLD DETAIL WITH QUICK COUPLING VALVE SCALE: NONE
CARSON 1220 RECTANGULAR VALVE
BOX FOR FOUR VALVES OR CARSON
1419 FOR TWO VALVES
REMOTE CONTROL VALVE WITH
FLOW CONTROL AND MANUAL
BLEED. REFER TO TWO OR FOUR
VALVE MANIFOLD DETAIL FOR
INSTALLATION INSTRUCTIONS
VALVE CONTROL WIRE- PROVIDE
3M-DBY SEAL PACKS AT ALL
SPLICES AND 24" OF EXCESS UF
WIRE IN A 1" DIAMETER COIL
BRICK-1 EACH CORNER
FINISH GRADE
1 2
5 6
7 4
3 2
1 5
19 GAUGE 1/2" SQUARE WIRE MESH.
WRAP UP THE SIDES OF THE BOX
PEA GRAVEL OR 3/4" DRAIN ROCK- 4"
DEEP BELOW VALVE (NO SOIL IN
VALVE BOX)
BUBBLER OR SPRAY REMOTE CONTROL VALVE
IN TWO OR FOUR VALVE MANIFOLD
FLOW
6 7
3 4
5 8
SCH 40 PVC LATERAL LINE TO
BUBBLERS OR SPRAY
8 SCALE: NONE
CARSON 1220 RECTANGULAR VALVE
BOX FOR FOUR VALVES OR CARSON
1419 FOR TWO VALVES
VALVE CONTROL WIRE- PROVIDE
3M-DBY SEAL PACKS AT ALL
SPLICES AND 24" OF EXCESS UF
WIRE IN A 1" DIAMETER COIL
BRICK-1 EACH CORNER
FINISH GRADE
1 2
5 6
9 4
3 2
1 6
19 GAUGE 1/2" SQUARE WIRE MESH.
WRAP UP THE SIDES OF THE BOX
PEA GRAVEL OR 3/4" DRAIN ROCK- 4"
DEEP BELOW VALVE (NO SOIL IN
VALVE BOX)
DRIP REMOTE CONTROL VALVE IN TWO OR
FOUR VALVE MANIFOLD
7 9
3 4
5 6
SCH 40 PVC LATERAL LINE TO
DRIPLINE OR DRIP.
8 8
7 DRIP FILTER AND REGULATOR
REMOTE CONTROL VALVE WITH
FLOW CONTROL AND MANUAL
BLEED. REFER TO TWO OR FOUR
VALVE MANIFOLD DETAIL FOR
INSTALLATION INSTRUCTIONS
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
08.05. 2022
DATE# REVISION LIST
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
L506
1/16" = 1'-0"
IRRIGATION DETAILS
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
SCALE: NONE
COPPER MAIN AND ELECTRICAL CONDUIT THRU
STUCTURE STUB OUT2
1 2
3 4
8 7
BRONZE BALL VALVE.
6 10
9 COPPER 90° ELBOW.
COPPER MALE ADAPTER.
CONDUIT FOR CONTROL WIRES
THROUGH STRUCTURE PROVIDED BY
ELECTRICAL CONTRACTOR.
WATERPROOF ALL PENETRATIONS
COPPER PIPE THROUGH STRUCTURE
PROVIDED BY PLUMBING
CONTRACTOR. WATERPROOF ALL
PENETRATIONS.
10 2
4 7
TWO-WIRE CABLE OR CONTROL
WIRES
9 6
SCH 40 PVC MALE ADAPTER.
3 EXTERIOR WALL
5 5
PVC MAIN LINE TO REMOTE CONTROL
VALVES.
FINISH GRADE
8 11
11 10" ROUND PLASTIC VALVE BOX
WITH BRICKS TO SUPPORT BOX.
1 SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 7
9 2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
5 7
DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
NOTES & DETAILS - L506
LANDSCAPE - IRRIGATION
Attachment 6
67 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
08.05. 2022
DATE# REVISION LIST
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
L507
1/16" = 1'-0"
IRRIGATION DETAILS
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
1 4
6 2
#14AWG TWO WIRE CABLE FROM
CONTROLLER. REFER TO IRRIGATION NOTES
FOR MODEL NUMBER OF WIRE. ALLOW A
24" SLACK PER DECODER. USE ELECTRICAL
TAPE TO HOLD SLACK CABLES TOGETHER.
DECODER
TWO WIRE CABLE TO NEXT DECODER
ALL DECODERS SHALL HAVE A VALVE NUMBER ADDRESSED AT
CONTROLLER PRIOR TO INSTALLATION.
NOTE:
1. 8 VALVE BOX. REFER TO REMOTE
CONTROL VALVE DETAIL FOR
INSTALLATION INSTRUCTIONS.
9 REMOTE CONTROL VALVE. REFER TO
REMOTE CONTROL VALVE DETAIL FOR
INSTALLATION INSTRUCTIONS.3M DBR/Y-6 OR APPROVED EQUAL
WATERPROOF SPLICE KIT (4 TOTAL)
DECODER WIRING IN CONDUIT
SCALE: NONE
2 1
6 7
3 3
9 8
3 DECODER
USE U.F. SAFETY CABLE STRIPPER BY KING INNOVATION (MODEL NUMBER 46200) FOR ALL TWO-WIRE SPLICE CONNECTIONS.
2. A MAXIMUM OF 4" OF WIRE SHALL BE
STRIPPED FROM TWO WIRE CABLE WHEN
SPLICING AT DECODERS.
4 CONNECT CORRECT DECODER WIRES
TO VALVE SOLENOID WIRES
7 5
5 CONNECT CORRECT DECODER WIRES TO
TWO WIRE CABLES.
10 1.25" CONDUIT FOR 2 WIRE CABLE
WITH LONG SWEEPS IN AND OUT OF
EACH VALVE BOX. SEAL ALL CONDUIT
OPENINGS WITH WATERPROFF
FOAM.
4 SCALE: NONE
TWO WIRE
CABLE
10" ROUND VALVE BOX
2-WIRE SPLICE BOX AT MAIN LINE TEE OR 3
WAY WIRE BRANCH
3M DBR/Y-6 OR
APPROVED EQUAL
WATERPROOF
CONNECTOR.
SCALE: NONE
2 1
2 3
4 2-WIRE PATH JACKETED/ TWISTED
TO NEXT DECODER
6 INSTALL 5/8" DIAMETER COPPER
GROUND ROD OF 8' LENGTH.
7 NOTE:
2-WIRE PATH JACKETED/ TWISTED FROM
CONTROLLER. ALLOW A 24" SLACK PER
DECODER
LIGHTNING ARRESTOR
1 2
3 4
7 5
1.25" CONDUIT FOR 2 WIRE CABLE
WITH LONG SWEEPS IN AND OUT OF
EACH VALVE BOX. SEAL ALL CONDUIT
OPENINGS WITH WATERPROOF
FOAM.
CONDUIT FOR
TWO WIRE CABLE.
SEAL OPENINGS WITH
WATERPROOF FOAM.
FINISH GRADE
SCALE: NONE
1 IRRIGATION TWO WIRE PULL BOX
3M DBR/Y-6 OR APPROVED EQUAL
WATERPROOF SPLICE KIT (4 TOTAL)
11 10
BRICK-ONE ON EACH CORNER11
8 BRICK-ONE ON EACH CORNER8
PEA GRAVEL
BRICK-ONE ON
EACH CORNER1
2 3
5 3"
1 6
3 FINISH GRADE
24" LOOP OF TWO WIRE CABLE.
SCHEDULE 40 U.L. LISTED PVC
CONDUIT
8 PEA GRAVEL OR 3/4" [20mm] DRAIN
ROCK - 4" [102mm] DEEP BELOW
VALVE (NO SOIL IN VALVE BOX).
8 2
5 BRICK-ONE ON EACH CORNER
4 7
7 SEAL ALL CONDUIT OPENINGS
WITH WATERPROOF FOAM.
9 9
GREY RECTANGULAR PLASTIC VALVE
BOX WITH BOLT DOWN LID. HEAT
BRAND "PB" INTO LID.
LIGHTNING ARRESTOR (MODEL
WT2W-LSP). 1 EVERY 500' FROM
STARTING FROM CONTROLLER.
TWO WIRE DECODER SYSTEMS MUST BE PROPERLY GROUNDED IN ORDER TO PROTECT AGAINST LIGHTNING SURGES. THE COMMUNICATION CABLE MUST BE GROUNDED NO FURTHER THAN 500' FROM ANY DECODER. THE SURGE DEVICE MUST BE A WEATHERTRAK MODEL WT2W-LSP. THE MINIMUM DISTANCE BETWEEN THE SURGE ARRESTOR AND THE GROUND ROD SHOULD BE 3' (91.4CM). WEATHERTRAK
RECOMMENDS A SPLIT BOLT CONNECTION TO BE USED TO CONNECT THE SURGE DEVICE TO THE GROUND WIRE WITH A 3M DBY-6 WATERPROOF CONNECTOR. 9 9 GREY RECTANGULAR PLASTIC VALVE
BOX WITH BOLT DOWN LID. HEAT
BRAND "GR" INTO LID.
6 4
SCHEDULE 40 PVC SWEEP ELLS
18 GAUGE 1/2" [13mm] SQUARE
STAINLESS STEEL WIRE MESH.
6 5 18 GAUGE 1/2" [13mm] SQUARE
STAINLESS STEEL WIRE MESH.
CONTROLLER ID AND
STATION NUMBER.
INSTRUCTIONS:
TOP VIEW
36"
EDGE OF LAWN, WALK, ETC.
SCALE: NONE
CENTER VALVE BOX OVER REMOTE CONTROL VALVES TO
FACILITATE SERVICING VALVE.
SET BOXES 1" ABOVE FINISH GRADE OR MULCH COVER IN GROUND COVER/SHRUB AREA AND FLUSH WITH FINISH GRADE IN TURF AREA.
SET RCV AND VALVE BOX ASSEMBLY IN GROUND COVER/SHRUB AREA WHERE POSSIBLE. INSTALL IN LAWN ONLY IF GROUND COVER DOES NOT EXIST ADJACENT TO LAWN.
SET BOXES PARALLEL TO EACH OTHER AND PERPENDICULAR TO
EDGE OF LAWN, WALK, FENCE, CURB, ETC.
AVOID HEAVILY COMPACTING SOIL AROUND VALVE BOXES TO
PREVENT COLLAPSE AND DEFORMATION OF VALVE BOX SIDES.
INSTALL EXTENSION BY VALVE BOX MANUFACTURER AS
REQUIRED TO COMPLETELY ENCLOSE ASSEMBLY FOR EASY
ACCESS.
1. 2.
3. 4.
5. 6.
10" DIAMETER ROUND VALVE
BOX. FOR QCV AND GATE
VALVE. HEAT BRAND VALVE
TYPE INTO INTO LID
15" x 21" OR 14" x 19"
RECTANGULAR VALVE
BOX.
8 VALVE BOX INSTALLATION (ALL BOXES
AND LID ARE BLACK IN COLOR)
12"
SCALE: NONE
6 QUICK COUPLING VALVE
NOTE:
SIDE VIEW
TOP VIEW
10" ROUND PLASTIC VALVE BOX
WITH BOLT DOWN LID.
1 1/4" x 1 1/4" x 3/16" [30mm x 30mm x
5mm] ANGLE IRON 30" [760mm]
LONG W/2 STAINLESS STEEL
STRAPS (ONE AROUND QCV).
PVC MAIN LINE.
3" [75mm] LONG SCHEDULE 80 PVC
THREADED NIPPLE.
QUICK COUPLING VALVE.
SCHEDULE 80 PVC THREADED
NIPPLE.
10" [250mm] LONG SCHEDULE 80
PVC THREADED NIPPLE.
UPC APPROVED SCHEDULE 40 PVC
TEE OR ELBOW.
SCHEDULE 80 PVC THREADED 90°
ELL.
1 2
3 4
5 6
7 8
9 10
NIPPLES AND FITTINGS TO BE
SAME SIZE AS VALVE IPT INLET
THREAD SIZE.
REFER TO
IRRIGATION
LEGEND
1 2
3 4
6 5
9 10
11 12
FINISH GRADE.
7 8
19 GAUGE 1/2" [13mm] SQUARE
WIRE MESH.
BRICK - 2 TOTAL.
11 12
PEA GRAVEL OR 3/4" DRAIN ROCK- 4"
[100mm] DEEP BELOW VALVE (NO
SOIL IN VALVE BOX).
13 13
SCALE: NONE
NOTE:
1. NIPPLES AND FITTINGS TO BE SAME SIZE AS VALVE IPT INLET THREAD SIZE.
2. TRIM VALVE BOX LENGTH AS NECESSARY TO BE FLUSH WITH TOP OF PLANTING TILES.
3. IF NECESSARY SLOT SIDES VALVE BOX TO ALLOW PASSAGE OF PIPE THROUGH BOTTOM OF VALVE BOX.
QUICK-COUPLING VALVE
VALVE BOX WITH COVER:
10-INCH SIZE. CUT BOX TO FIT
WITHIN SOIL AREA.
PVC SCH 80 NIPPLE
(LENGTH AS REQUIRED)
PVC SCH 80 NIPPLE
(LENGTH AS REQUIRED)
SIDE VIEW
SCHEDULE 80 PVC
THREADED 90° ELL.
INSTALL ON TWO BRICKS OR
DIRECTLY ON FOAM OR
WATERPROOFING.
FINISH GRADE
CRUSHED ROCK
QUICK COUPLING VALVE-ON STRUCTURE
-UPPER LEVEL7
ALL TREE VALVES
TO HAVE TREE
BRANDED INTO
LID.
5 POP-UP SPRAY SPRINKLER - SHRUB
24"
1"
1 2
3 4
5 6
WALL, WALK, CURB OR BUILDING.
PVC LATERAL LINE.
UPC APPROVED SCHEDULE 40 PVC
TEE OR ELBOW.
POP-UP SHRUB SPRAY SPRINKLER
OR BUBBLER.
FINISH GRADE.
1/2" [13mm] SCHEDULE 80 PVC
THREADED NIPPLE (LENGTH AS
REQUIRED).
1/2" [13mm] SCHEDULE 40 PVC
THREADED 90° ELL.
1/2" [13mm] SCHEDULE 40 PVC
STREET ELL.
7 8
9 1
2 3
4 5
6 7
8 9
[25mm]
1/2" [13mm] FLEXIBLE IPS HOSE 6"
[150mm] LONG WITH MALE
ADAPTERS OR 1/2" [13mm] FLEXIBLE
SWING JOINT (1/2" x 6") [13mm x
150mm] WITH A MINIMUM
PRESSURE RATING OF 100 PSI
[690kPa].
12" BETWEEN
SPRINKLERS AND 18"
BELOW SPRINKLER
SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 7
9 2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
5 7
DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
NOTES & DETAILS - L507
LANDSCAPE - IRRIGATION
Attachment 6
68 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the If this drawing is not 24"x36", then the drawing has been revised from its original size.
KEYPLAN
-
08.05. 2022
DATE# REVISION LIST
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
L508
1/16" = 1'-0"
IRRIGATION DETAILS
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
SCALE: NONE
1 TRENCHING
2 1
3 4
5 CLEAN BACKFILL MATERIAL.
FINISH GRADE.
LATERAL LINE. MAIN LINE.
TWO WIRE CABLE IN CONDUIT4 3" DETECTABLE WARNING TAPE OVER MAIN LINE.
INSTALL 3" ABOVE MAIN LINE. USE CHRISTY MODEL
#TA-DT-3-BIRR FOR POTABLE IRRIGATION SYSTEMS OR
#TA-DT-3-PRW FOR RECYCLED IRRIGATION WATER
SYSTEMS
NOTES:
1. ALL MAIN SUPPLY LINES AND LATERAL LINES SHALL BE PLACED IN SLEEVES UNDER PAVED SURFACES. INSTALL LOW VOLTAGE WIRES WITHIN A SEPARATE CONDUIT UNDER PAVED SURFACES. DO NOT TAPE WIRES WITHIN CONDUIT.
2. REUSE SALVAGED EXCAVATED FILL AND COMPACT TO ORIGINAL DENSITY IN LANDSCAPE AREAS. ALL OTHER AREAS SHALL BE AT 95% COMPACTION.
BACKFILL MATERIAL SHALL BE THE EARTH EXCAVATED FROM THE TRENCHES, FREE FROM ROCKS (ANYTHING LARGER THAN 2"), CONCRETE CHUNKS, AND OTHER FOREIGN OR COARSE MATERIALS.
3. WHEN 12" POP-UP SPRINKLER HEADS ARE USED, INCREASE THE DEPTH OF LATERAL TO 18" AT THE SPRINKLER LOCATION ONLY.
8"-12" MIN.
LATERAL, MAIN,
AND WIRES
6" MIN.
MAIN AND
WIRES ONLY
LATERAL
ONLY
MULTIPLE
LATERALS
4"
18"
12"
4"
2 1
3 4
6 5
SCALE: NONE
6 TORO DL 2000 CENTER FEED MANIFOLD
1 2
3 4
5 6
7 8
9 ISOMETRIC
9 8
7 6
54 3
1 2
NOTE:
THE TOTAL LENGTH OF A SINGLE DRIP LINE RUN SHALL NOT EXCEED 300 FT.
FINISH GRADE.
DEPTH OF TUBING PER
IRRIGATION LEGEND.
DEPTH OF PVC LATERAL LINE
PER IRRIGATION LEGEND
DRIPLINE TUBING.
BLANK 5/8" [16mm] POLY
TUBING, LENGTH AS
NECESSARY.
PVC TEE (SxSxT) WITH 1/2" [13mm]
FPT OUTLET.
PVC LATERAL LINE FROM REMOTE
CONTROL VALVE.
TORO TRI-LOC TEE (TL-T)
TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIP RINGS AROUND TREE
SCALE: NONE
2 3
4 5
6 BLANK TUBING
DRIPLINE
LOC-EZE TEE (TYP)
TREE TRUNK
2 3
4 5
7 9
2 6
1 12"
8 1 FIGURE 8 LINE END 7 ROOT BALL
8 3
ADAPTER TEE FROM PVC TO
DRIPLINE.
6-INCH SOIL STAPLE (TYP)
EQUALLY SPACE 4 AROUND EACH
TUBE RING
9 LOCATE FIRST DRIPLINE RING
HALFWAY BETWEEN THE TRUNK AND
EDGE OF ROOTBALL. LOCATE THE
SECOND DRIPLINE RING AT EDGE OF
ROOTBALL. LOCATE THE THIRD RING
12" OUTSIDE THE SECOND RING
NOTE:
SUGGESTED QUANTITY DRIP RINGS PER TREES SIZE:
· 15 GAL OR 24" BOX = 2 RINGS
· 36 GAL OR 48" BOX = 3 RINGS
· 60 GAL OR LARGER = 4 RINGS
SCALE: NONE
DET: TRENCH
2 1
2 3
CLEAN BACKFILL MATERIAL.
FINISH GRADE.
1 2
3 6"-8"
ALL LATERAL LINES SHALL BE PLACED IN SLEEVES UNDER PAVED SURFACES.
1. NOTES:
PVC LATERAL LINE.
TRENCHING UPPER LEVELS
SCALE: NONE
4 TORO DL 2000 CENTER FEED LAYOUT
SCALE: NONE
5 TORO DL 2000 END FEED LAYOUT
11 10
8 9
1 2
3 4
5 6
7 FLUSH VALVE PLUMBED
TO FLUSH MANIFOLD AT
LOW POINT
MANIFOLD-TO-ELBOW
CONNECTION (TYP).
PVC LATERAL LINE FROM
VALVE. MINIMUM SIZE TO
BE 1" UNLESS OTHERWISE
NOTED.
MANIFOLD-TO-TEE
CONNECTION.
DRIPLINE LATERAL.
AIR/VACUUM RELIEF
LATERAL, BLANK POLY
TUBING CENTERED ON
MOUND OR BERM.
AIR/VACUUM RELIEF
PLUMBED TO BLANK 5/8"
POLY TUBING AT EACH
HIGH POINT.
PERIMETER LATERALS
2" [50mm] TO 4" [100mm]
FROM EDGE.
AREA PERIMETER.
12 DRIPLINE OPERATION
INDICATOR LOCATED AT
THE ENDS OF EACH
DRIPLINE ZONE.
11 10
8 9
1 2
3 4
5 6
7 MANIFOLD-TO-ELBOW
CONNECTION (TYP).
DRIPLINE LATERAL.
AIR/VACUUM RELIEF
VALVE PLUMBED TO
BLANK 5/8" TUBING AT
EACH HIGH POINT.
AIR/VACUUM RELIEF
LATERAL, BLANK 5/8"
POLY TUBING
CENTERED ON MOUND
OR BERM.
PERIMETER LATERALS
2" [50mm] TO 4" [100mm]
FROM EDGE.
AREA PERIMETER.
DRIP OPERATION
INDICATOR LOCATED AT
THE ENDS OF EACH
DRIPLINE ZONES.
AUTOMATIC FLUSH
VALVE PLUMBED TO
FLUSH MANIFOLD AT
LOW POINT.
NOTE:
1. THE TOTAL LENGTH OF ALL INTERCONNECTED DRIP
LINE OFF A SINGLE PVC SUPPLY LINE CONNECTION OR
A SINGLE RUN OF DRIPLINE SHALL NOT EXCEED 300 FT.
2. INSTALL DRIPLINE 2"-4" BELOW GRADE AND STAKE
DOWN EVERY 4' OR AS REQUIRED.
PVC FLUSH MANIFOLD.
MINIMUM SIZE TO BE 1"
UNLESS OTHERWISE
NOTED.
PVC LATERAL LINE
FROM VALVE. MINIMUM
SIZE TO BE 1" UNLESS
OTHERWISE NOTED.
1" FLEXIBLE PVC IPS
HOSE FLUSH MANIFOLD.
1" FLEXIBLE PVC IPS
HOSE FLUSH MANIFOLD.
NOTE:
1. THE TOTAL LENGTH OF ALL INTERCONNECTED DRIP
LINE OFF A SINGLE PVC SUPPLY LINE CONNECTION OR
A SINGLE RUN OF DRIPLINE SHALL NOT EXCEED 300 FT.
2. INSTALL DRIPLINE 2"-4" BELOW GRADE AND STAKE
DOWN EVERY 4' OR AS REQUIRED.
PLAN
FV
FV
AV
PVC SUPPLY MANIFOLD.
EXTEND TO END OF
ZONE/EXHAUST
HEADER.
1 2
3 4
5 6
7 8
9 10
11 1212
PLAN
FV
AV
10 9
8 7
6 5
4 3
2 1
11 SCALE: NONE
DRIPLINE-FLUSH POINT8
3 7
5 4
2 1
1" IPS PVC HOSE FROM EXHAUST HEADER.
BRICK (1 OF 2)
NOTE:
ALLOW A MINIMUM OF PVC HOSE IN VALVE BOX IN ORDER TO DIRECT FLUSHED WATER OUTSIDE VALVE BOX.
2 4
5 1
6 6 7
1/2" SCH 40 THREADED
BALL VALVE.
6" BLACK ROUND PLASTIC
VALVE BOX WITH PURPLE
LID.
PEA GRAVEL SUMP (6"
DEEP).
FINISH GRADE
3 1/2" SCH 40 MALE
ADAPTER.
7 570 POP-UP DRIP OPERATION INDICATOR
FINISH GRADE.
570 POP-UP DRIP OPERATION INDICATOR ASSEMBLY
(TORO MODEL 570-DRIP-IND) INSTALLED AT FURTHEST
POINT DOWNSTREAM OF ZONE VALVE.
PVC OR SWING PIPE SWING JOINT ASSEMBLY.
PVC DRIP ZONE FOOTER.
DEPTH OF PVC LINE PER SPECIFICATIONS.
NOTE: TEFLON TAPE ALL THREADED JOINTS
1 2
3 4
5 10"-12"
5 4
6" MIN. 8"-12" MIN.
SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 7
9 2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
5 7
DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
LANDSCAPE - IRRIGATION
NOTES & DETAILS - L508
Attachment 6
69 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
08.05. 2022
# REVISION LIST
ANDREA COCHRAN
LANDSCAPE ARCHITEC
2325 Third Street #210
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
1/16" = 1'-0"
IRRIGATION DETAILS
Irrigation Consultant:
2760 Camino Diablo
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
REFER TO
IRRIGATION
LEGEND
4"
1 FINISH GRADE
3 4
5 8
7 6
9 2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
1 8
2 3
6 TORO TRI-LOC ELBOW
(TL-E)
5 7
4 DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
21 SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 7
9 2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
5 7
DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
LANDSCAPE - IRRIGATION
NOTES & DETAILS - L509
Attachment 6
70 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
WATER TYPE POTABLE
SITE ETO= 45.5
9/29/2022
HYDROZONE # HYDROZONE NAME PLANT WATER
USE TYPE
PLANT
FACTOR (PF)
IRRIGATION
METHOD
IRRIGATION
EFFICIENCY ETAF (PF/IE) AREA (SQ. FT)
(HA) ETAF X AREA (HA) ETWU
(GAL/YR)
ACRE FEET/
YEAR HCF/ YEAR PERCENTAGE OF
LANDSCAPE
1 GROUNDCOVER LOW 0.3 DRIP 0.81 0.37 4,689 1,737 48,991 0.15 65.50 15% 2 SHRUBS MOD 0.5 DRIP 0.81 0.62 2,276 1,405 39,633 0.12 52.99 7% 2 SHRUBS LOW 0.3 DRIP 0.81 0.37 5,008 1,855 52,324 0.16 69.95 16% 3 TREES LOW 0.3 RINGS 0.81 0.37 2,200 815 22,986 0.07 30.73 7% 4 TREES MOD 0.5 RINGS 0.81 0.62 2,200 1,358 38,310 0.12 51.22 7% 5 STORMWATER MOD 0.5 SPRAY 0.75 0.67 2,666 1,777 50,139 0.15 67.03 8% 6 VINE MOD 0.5 BUBBLER 0.81 0.62 126 78 2,194 0.01 2.93 0% 7 GRASS PLUGS HIGH 0.7 SPRAY 0.75 0.93 2,101 1,961 55,318 0.17 73.95 7% 8 PLANTING AREA 1 MOD 0.5 DRIP 0.81 0.62 6,269 3,870 109,166 0.34 145.94 20% 9 PLANTING AREA 2 LOW 0.3 DRIP 0.81 0.37 3,228 1,196 33,727 0.10 45.09 10% 10 POOL/SPA HIGH 0.7 1 1,025 3%
31,788 16,051 452,788 1.39 605.33 100%
HYDROZONE # HYDROZONE NAME
1 0%
TOTALS 0 0%
493,207
1.51 659.37
452,788 ETo = REFERENCE EVAPOTRANSPIRATION ETo = REFERENCE EVAPOTRANSPIRATION
1.39 0.45= ET ADJUSTMENT FACTOR PF = PLANT FACTOR FOR HYDROZONES 605.33 LA=LANDSCAPED AREA (SQUARE FEET) HA = HYDROZONE AREA (SQ.FT)
SITE IRRIGATION
EFFICIENCY SITE PLANT FACT0R
MAWA
COMPLIANT IE = IRRIGATION EFFICIENCY (0.81)-BUBBLER/DRIP
80.7% 0.42 YES IE = IRRIGATION EFFICIENCY (0.75)-ROTORS/SPRAY TOTAL ETAF x AREA 16,051
TOTAL AREA 31,788
AVG. ETAF 50.49%
REGULAR LANDSCAPE AREAS
GALLONS/YR
ETWU
ETAF Calculations
WATER USE ESTIMATION-Kifer Development -Ground, 4th and 8th Floor LVL-Sunnyvale
SPECIAL LANDSCAPE AREAS
REGULAR LANDSCAPE AREAS
ACRE FEET/YR
HCF/YR
MAWA
ETWU= ((ETO)(.62)(ETAF x LA))MAWA = (ETo)(0.62)[(LA x 0.55) + (0.45 x SLA)]
ETWU FORMULA
TOTALS
MAXIMUM APPLIED WATER ALLOWANCE (MAWA)
GALLONS PER YEAR
0.62 = CONVERSION FACTOR (GALLONS/SQ.FT/YR)0.62 = CONVERSION FACTOR (GALLONS/SQ.FT/YR)
ACRE FEET/YR
HCF/YR
MAWA FORMULA
GALLONS/YR
ESTIMATED TOTAL WATER USE (ETWU) GALLONS PER
YEAR
SHEE
SHEE
PRO
DATE
SCAL
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch KEYP
#
IRR
Irrigation Consultant:
2760 Camino Diablo
Walnut Creek, CA 94597
tel 925.939.3985 t fax 925.932.5671
www.rmairrigation.com
NOT TO SCALE
SECTION
SCALE: NONE
DRIPLINE TO PVC CONNECTION1
1 FINISH GRADE
8 7
9 2 CARSON 708 OR EQUAL.
COLOR: BLACK
3 DRIPLINE TUBING
4 TORO TRI-LOC TEE X 1/2"
FPT ADAPTER
5 TORO 1/2" CHECK VALVE
(PCV-500)
6 1/2" SCH 40 MALE ADAPTER.
7 8
BRICK (1 OF 2)
1/2" SCH 40 PVC (LENGTH AS
REQUIRED)
9 PVC LATERAL LINE SUPPLY.
MINIMUM SIZE TO BE 1" UNLESS
SIZED DIFFERENTLY ON
DRAWINGS. USE SCH 40 PVC
1"x1"x1/2" TEE OR 90° ELBOW.
SCALE: NONE
2 DRIPLINE MANIFOLD TO ELBOW CONNECTION
1 2
3 4
5 6FINISH GRADE TORO TRI-LOC MPT
ADAPTER (TL-M50)
DRIPLINE TUBING
TORO BLUE STRIPE POLY
TUBING (EHD1645)
SECTION/ELEVATION
NOT TO SCALE
6 TORO TRI-LOC ELBOW
(TL-E)
5 7
DEPTH OF TUBING PER
IRRIGATION LEGEND.
7 SCH 40 PVC TEE (SxSxT)
WITH 1/2" FPT OUTLET.
8 DEPTH OF PVC LATERAL
LINE PER IRRIGATION
LEGEND
LANDSCAPE - IRRIGATION
WATER CALCULATIONS - L510
Attachment 6
71 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE - WATER EFFICIENT CHECKLIST
PROPOSED LOT 2 OFFICE L.O.W.
Attachment 6
72 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE - WATER EFFICIENT CHECKLIST
PROPOSED LOT 1 RESIDENTIAL
Attachment 6
73 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE SITE PLAN
1/32” = 1’-0”
HYDROZONE PLAN 1 OF 2
LOW 4,501 SF
-
MEDIUM 4,291 SF
-
CONCEPT PLANT SCHEDULE OFFICE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 20
# REVIS
KIFER DEVELOPMENT
NOT FOR
1/16" = 1
HYDROZONE
SHEET L601 SHEET L601
SEE SHEET 2 OF 2 SEE SHEET 2 OF 2
LOW 4,501 SF
-
MEDIUM 4,291 SF
-
CONCEPT PLANT SCHEDULE OFFICE
SHEET N
SHEET T
ISSUES
PROJECT
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
#
HYD
SHEET L601 SHEET L601
Attachment 6
74 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE SITE PLAN
1/32” = 1’-0”
HYDROZONE PLAN 2 OF 2
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
DN
UP
UP
DN
DN
UP
UP
UP
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
LOW 6,647 SF
-
HIGH 2,218 SF
-
MEDIUM 2,844 SF
-
CONCEPT PLANT SCHEDULE PROJECT SITE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
HYDROZONE P
SHEET L600 SHEET L600
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
DN
UP
UP
DN
DN
UP
UP
UP
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
LOW 6,647 SF
-
HIGH 2,218 SF
-
MEDIUM 2,844 SF
-
CONCEPT PLANT SCHEDULE PROJECT SITE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
#
N
1 HYDROZ
Attachment 6
75 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLAN LEVEL 4
1/32” = 1’-0”
HYDROZONE PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
2 A300
1 A300
1 A400
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
LOW 3,530 SF
-
MEDIUM 1,466 SF
-
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
HYDROZONE P
LEVEL 4
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
2 A300
1 A300
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
LOW 3,530 SF
-
MEDIUM 1,466 SF
-
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
# REVISION L
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
HYDROZONE P
LEVEL 4
Attachment 6
76 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLAN LEVEL 8
1/32” = 1’-0”
HYDROZONE PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
2 A300
1 A300
1 A400
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
LOW 220 SF
-
MEDIUM 65 SF
-
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
HYDROZONE P
LEVEL 8
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
2 A300
1 A300
2 A400
3 A400
1 A607
1 A608
1 A201
1 A200
2 A201
EASEMENTS SEE CIVIL PLANS
LOW 220 SF
-
MEDIUM 65 SF
-
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
# REVISION
KIFER DEVELOPMENT
NOT FOR CO
1/16" = 1'-0"
HYDROZONE P
LEVEL 8
Attachment 6
77 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
TREE #709
TREE #705
TREE #560
TREE #656
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702
TREE #697
TREE #704
TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
TREE #561
TREE #562
NO TAG
TREE - MEDIUM - 36" BOX 1
NYSSA SYLVATICA `WILDFIRE`
ACER CIRCINATUM
TREE - LOW - 36" BOX 5
AESCULUS CALIFORNICA
CERCIS OCCIDENTALIS `ALBA`
EXISTING TREE 16
VINE - MEDIUM - 5 GAL. - TRAINED ON STAKE 16
FICUS PUMILA
CONCEPT PLANT SCHEDULE OFFICE
GROUND COVER - 1 GAL. 1,916 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
PLANTING AREA - MEDIUM - 5 GAL. 4,291 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 2,585 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT` - LOW
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 20
# REVIS
KIFER DEVELOPMENT
NOT FOR
1/16" = 1
PLANTING P
SHEET L601 SHEET L601
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
TREES ARE 36" BOX.
SEE SHEET 2 OF 2 SEE SHEET 2 OF 2
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
TREE #709
TREE #705
TREE #560
TREE #656
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702
TREE #697
TREE #704
TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
TREE #561
TREE #562
NO TAG
TREE - MEDIUM - 36" BOX 1
NYSSA SYLVATICA `WILDFIRE`
ACER CIRCINATUM
TREE - LOW - 36" BOX 5
AESCULUS CALIFORNICA
CERCIS OCCIDENTALIS `ALBA`
EXISTING TREE 16
VINE - MEDIUM - 5 GAL. - TRAINED ON STAKE 16
FICUS PUMILA
CONCEPT PLANT SCHEDULE OFFICE
GROUND COVER - 1 GAL. 1,916 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
PLANTING AREA - MEDIUM - 5 GAL. 4,291 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 2,585 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT` - LOW
SHEET N
SHEET T
ISSUES
PROJECT
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
#
PLAN
SHEET L601 SHEET L601
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
TREES ARE 36" BOX.
LANDSCAPE SITE PLAN
1/32” = 1’-0”
PLANTING PLAN 1 OF 2
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
TREE #709
TREE #705
TREE #560
TREE #656
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702
TREE #697
TREE #704
TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
TREE #561
TREE #562
NO TAG
1 `
5 `
16 NED ON STAKE 16
GROUND COVER - 1 GAL. 1,916 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
PLANTING AREA - MEDIUM - 5 GAL. 4,291 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 2,585 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT` - LOW
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L600
1/16" = 1'-0"
PLANTING PLAN
SHEET L601
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
TREES ARE 36" BOX.
Attachment 6
78 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLANT IMAGES
GROUND LEVEL OFFICE PROPOSED PLANTING SHEET 1 OF 2
Tree Medium - 36” BOX
Nyssa sylvatica ‘Wildfire’
Tree Medium - 36” BOX
Acer circinatum
Tree Low - 36” BOX
Aesculus californica
Tree Low - 36” BOX
Cercis occidentalis ‘Alba’
Vine - Medium - 5 Gal
Trained on Stake
Ficus pumila
Ground Cover - 1 Gal.
Fragaria vesca - Medium
Ground Cover - 1 Gal.
Rhamnus Californica ‘Eve
Case’ - Low
Ground Cover - 1 Gal.
Arctostaphylos ‘Pacific Mist’
- Low
Ground Cover - 1 Gal.
Dymondia margaretae - Low
Plant Area - Medium - 5 Gal.
Pittosporum tenuifolium
‘Silver Sheen’
Plant Area - Low - 5 Gal.
Ceanothus griseus var. hori-
zontalis ‘Yankee Point’
Plant Area - Low - 5 Gal.
Olea europaea Little Olle -
Very Low
Attachment 6
79 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
Plant Area - Low - 5 Gal
Muhlenbergia dubia
Plant Area - Low - 5 Gal
Achillea millefolium
Plant Area - Low - 5 Gal
Lomandra longifolia Breeze
Plant Area - Low - 5 Gal
Agave ‘Blue Flame’
Plant Area - Low - 5 Gal
Melianthus major ‘Antanow’s
Blue’
Plant Area - Low - 5 Gal
Lomandra ’Platinum beauty’
Plant Area - Low - 5 Gal
Acacia cognata ‘Cousin Itt’
LANDSCAPE PLANT IMAGES
GROUND LEVEL OFFICE PROPOSED PLANTING SHEET 2 OF 2
Attachment 6
80 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 37
LANDSCAPE SITE PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
DN
UP
UP
DN
DN
UP
UP
UP
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
TREE #560
TREE
#539
TREE
#552
TREE
#553
TREE
#554
TREE
#555
TREE
#556
TREE
#557
TREE
#558
15'-0"
LANDSCAPE
FRONTAGE STRIP
SHADE TREE - 36" BOX 8
GINKGO BILOBA COLUMNAR
ACER X FREEMANII
TREE - MEDIUM - 36" BOX 14
NYSSA SYLVATICA `WILDFIRE`
ACER CIRCINATUM
TREE - LOW - 36" BOX 20
AESCULUS CALIFORNICA
CERCIS OCCIDENTALIS `ALBA`
EXISTING TREE 8
CONCEPT PLANT SCHEDULE PROJECT SITE
SHRUB - MEDIUM - 5 GAL. 138
BUXUS SEMPERVIRENS `MONRUE` TM
SHRUB - LOW - 5 GAL. 152
RHAMNUS ALATERNUS `JOHN EDWARDS`
VINE - MEDIUM - 5 GAL. - TRAINED ON STAKE 26
FICUS PUMILA
GRASSES - LOW - 5 GAL. 107
DIETES GRANDIFLORA
LOMANDRA `PLATINUM BEAUTY`
STORMWATER 2,645 SF
CERCIS CANADENSIS - MEDIUM 36" BOX
CHRONDROPETALUM TECTORUM - LOW TO MEDIUM 5 GAL.
CORNUS SERICEA - HIGH 5 GAL.
CALYCANTHUS OCCIDENTALIS - MEDIUM 5 GAL.
JUNCUS PATENS `ELK BLUE` - LOW 5 GAL.
GROUND COVER - 1 GAL. 2,732 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
GRASSCRETE 2,115 SF
NATIVE GRASS PLUGS - HIGH
PLANTING AREA - MEDIUM - 5 GAL. 1,920 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 646 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT`
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
PLANTING PLAN
SHEET L600 SHEET L600
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
1/32” = 1’-0”
PLANTING PLAN 2 OF 2
SEE SHEET
1 OF 2
SEE SHEET
1 OF 2
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
DN
UP
UP
DN
DN
UP
UP
UP
EASEMENTS SEE CIVIL PLANS
15'-0"
LANDSCAPE
FRONTAGE STRIP
TREE
#539
TREE
#552
TREE
#553
TREE
#554
TREE
#555
TREE
#556
TREE
#557
TREE
#558
15'-0"
LANDSCAPE
FRONTAGE STRIP
SHADE TREE - 36" BOX 8
GINKGO BILOBA COLUMNAR
ACER X FREEMANII
TREE - MEDIUM - 36" BOX 14
NYSSA SYLVATICA `WILDFIRE`
ACER CIRCINATUM
TREE - LOW - 36" BOX 20
AESCULUS CALIFORNICA
CERCIS OCCIDENTALIS `ALBA`
EXISTING TREE 8
CONCEPT PLANT SCHEDULE PROJECT SITE
SHRUB - MEDIUM - 5 GAL. 138
BUXUS SEMPERVIRENS `MONRUE` TM
SHRUB - LOW - 5 GAL. 152
RHAMNUS ALATERNUS `JOHN EDWARDS`
VINE - MEDIUM - 5 GAL. - TRAINED ON STAKE 26
FICUS PUMILA
GRASSES - LOW - 5 GAL. 107
DIETES GRANDIFLORA
LOMANDRA `PLATINUM BEAUTY`
STORMWATER 2,645 SF
CERCIS CANADENSIS - MEDIUM 36" BOX
CHRONDROPETALUM TECTORUM - LOW TO MEDIUM 5 GAL.
CORNUS SERICEA - HIGH 5 GAL.
CALYCANTHUS OCCIDENTALIS - MEDIUM 5 GAL.
JUNCUS PATENS `ELK BLUE` - LOW 5 GAL.
GROUND COVER - 1 GAL. 2,732 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
GRASSCRETE 2,115 SF
NATIVE GRASS PLUGS - HIGH
PLANTING AREA - MEDIUM - 5 GAL. 1,920 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 646 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT`
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
#
N
1 PLANTIN
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
TREES ARE 36" BOX.
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
+ 58.20 TREE #560
TREE #656
TREE #709
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702TREE #705
TREE #697
TREE #704 TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
POST
POST
POST
TREE #709
TREE #705
TREE #560
TREE #656
TREE #708
TREE #707
TREE #698
TREE #699
TREE #700
TREE #702
TREE #697
TREE #704
TREE #703 TREE #701
TREE #695
TREE #658
TREE #659
TREE #657
TREE #561
TREE #562
NO TAG
1 `
5 `
16 NED ON STAKE 16
GROUND COVER - 1 GAL. 1,916 SF
FRAGARIA VESCA - MEDIUM
ARCTOSTAPHYLOS `PACIFIC MIST` - LOW
RHAMNUS CALIFORNICA `EVE CASE` - LOW
DYMONDIA MARGARETAE - LOW
PLANTING AREA - MEDIUM - 5 GAL. 4,291 SF
PITTOSPORUM TENUIFOLIUM `SILVER SHEEN` - MEDIUM
PLANTING AREA - LOW - 5 GAL. 2,585 SF
CEANOTHUS GRISEUS VAR. HORIZONTALIS `YANKEE POINT` - LOW
OLEA EUROPAEA LITTLE OLLIE - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
LOMANDRA LONGIFOLIA BREEZE - LOW
AGAVE `BLUE FLAME` - LOW
MELIANTHUS MAJOR `ANTANOW`S BLUE` - LOW
LOMANDRA `PLATINUM BEAUTY` - LOW
ACACIA COGNATA `COUSIN ITT` - LOW
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L600
1/16" = 1'-0"
PLANTING PLAN
SHEET L601
NOTE: TOTAL REQUIRED TREES TO BE REPLACED IS 16. FOR
REQUIRED TREES TO BE REPLACED SUMMARY PLEASE SEE
TREE PROTECTION AND REMOVAL PLANS. ALL PROPOSED
TREES ARE 36" BOX.
Attachment 6
81 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLANT IMAGES
GROUND LEVEL SITE PROPOSED PLANTING SHEET 1 OF 2
Shade Tree - 36” BOX
Ginkgo Biloba Columnar
Shade Tree - 36” BOX
Acer x Freemanii
Tree Medium - 36” BOX
Nyssa Sylvatica ‘ Wildfire’
Tree Medium - 36” BOX
Acer Circinatum
Tree Low - 36” BOX
Aesculus californica
Tree Low - 36” BOX
Cercis occidentalis ‘Alba’
Shrub - Medium - 5 Gal
Buxus sempervirens ‘Monrue’
Grasses - Low - 5 Gal
Dietes grandiflora
Shrub - Low - 5 Gal
Rhamnus alaternus
‘John Edwards’
Vine - Medium - 5 Gal
Trained on Stake
Ficus pumila
Grasses - Low - 5 Gal
Lomandra ‘Platinum Beauty’
Attachment 6
82 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLANT IMAGES
Stormwater
Cercis canadensis
Medium - 36” Box
Stormwater
Chrondropetalum tectorum
Low to Medium - 5 Gal
Stormwater
Cornus Sericea
High - 5 Gal
Stormwater
Calycanthus occidentalis
Medium - 5 Gal
Stormwater
Juncus patens ‘Elk Blue’
Low - 5 Gal
Ground Cover - 1 Gal.
Fragaria Vesca - Medium
Grasscrete
Native Grass Plugs - High
Ground Cover - 1 Gal.
Arctostaphylos ‘Pacific Mist’
Low
Ground Cover - 1 Gal.
Rhamnus californica ‘ Eve
Case’ - Low
Ground Cover - 1 Gal.
Dymondia margaretae - Low
GROUND LEVEL SITE PROPOSED PLANTING SHEET 2 OF 2
Attachment 6
83 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 38
LANDSCAPE PLAN LEVEL 4
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
EASEMENTS SEE CIVIL PLANS
4TH LVL TREE - MEDIUM 23
BETULA NIGRA - MEDIUM TO HIGH
ACER CIRCINATUM - MEDIUM
AESCULUS X CARNEA - MEDIUM
4TH LVL TREE - LOW 24
LAURUS NOBILIS `SARATOGA` - LOW
OLEA EUROPAEA ‘SWAN HILL’ - LOW
4TH LVL PLANTING AREA - MEDIUM 1,466 SF
SESLERIA AUTUMNALIS - MEDIUM
4TH LVL PLANTING AREA - LOW 3,530 SF
LAURUS NOBILIS - LOW
OLEA EUROPAEA `LITTLE OLLIE` - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
PLANTING PLAN
1/32” = 1’-0”
PLANTING PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
EASEMENTS SEE CIVIL PLANS
4TH LVL TREE - MEDIUM 23
BETULA NIGRA - MEDIUM TO HIGH
ACER CIRCINATUM - MEDIUM
AESCULUS X CARNEA - MEDIUM
4TH LVL TREE - LOW 24
LAURUS NOBILIS `SARATOGA` - LOW
OLEA EUROPAEA ‘SWAN HILL’ - LOW
4TH LVL PLANTING AREA - MEDIUM 1,466 SF
SESLERIA AUTUMNALIS - MEDIUM
4TH LVL PLANTING AREA - LOW 3,530 SF
LAURUS NOBILIS - LOW
OLEA EUROPAEA `LITTLE OLLIE` - VERY LOW
MUHLENBERGIA DUBIA - LOW
ACHILLEA MILLEFOLIUM - LOW
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
# REVISION L
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
PLANTING PLAN
Attachment 6
84 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLANT IMAGES
4TH LEVEL PROPOSED PLANTING
4th Lvl Tree - Medium
Betula nigra
4th Lvl Tree - Medium
Acer circinatum
4th Lvl Tree - Medium
Aesculus x carnea
4th Lvl Tree - Low
Laurus nobilis ‘Saratoga’
4th Lvl Tree - Low
Olea europaea ‘Swan Hill’
4th Lvl Plant Area - Medium
Sesleria autumnalis
4th Lvl Plant Area - Low
Laurus nobilis - Low
4th Lvl Plant Area - Low
Olea europaea ‘Little Ollie’
4th Lvl Plant Area - Low
Muhlenbergia dubia
4th Lvl Plant Area - Low
Achillea millenfolium
Attachment 6
85 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 39
LANDSCAPE PLAN LEVEL 8
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 58.20 TREE #560
EASEMENTS SEE CIVIL PLANS
8TH LVL PLANTING AREA - LOW - 5 GAL. 220 SF
LAURUS NOBILIS - LOW
OLEA EUROPAEA `LITTLE OLLIE` - VERY LOW
AGAVE `BLUE FLAME` - LOW
8TH LVL PLANTING AREA - MEDIUM - 5 GAL. 65 SF
SESLERIA AUTUMNALIS - MEDIUM
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 2023
# REVISION L
LANDSCA
2325 Thir
San Fran
415.503.0
170 SAN ZENO WAY
KIFER DEVELOPMENT
NOT FOR CONS
1/16" = 1'-0"
PLANTING PLAN
1/32” = 1’-0”
PLANTING PLAN
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
+ 60.1 TREE #553
+ 60.9 TREE #552
+ 61.9 TREE #554
+ 60.8 TREE #555
+ 60.9 TREE #556
+ 61.7 TREE #557
+ 61.6 TREE #558
EASEMENTS SEE CIVIL PLANS
8TH LVL PLANTING AREA - LOW - 5 GAL. 220 SF
LAURUS NOBILIS - LOW
OLEA EUROPAEA `LITTLE OLLIE` - VERY LOW
AGAVE `BLUE FLAME` - LOW
8TH LVL PLANTING AREA - MEDIUM - 5 GAL. 65 SF
SESLERIA AUTUMNALIS - MEDIUM
CONCEPT PLANT SCHEDULE
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
# REVISION
KIFER DEVELOPMENT
NOT FOR CO
1/16" = 1'-0"
PLANTING PLA
Attachment 6
86 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
LANDSCAPE PLANT IMAGES
8TH LEVEL PROPOSED PLANTING
8th Lvl Planting Area - Low
Laurus nobilis
8th Lvl Planting Area - Low
Olea europaea ‘Little Ollie’
8th Lvl Planting Area - Low
Agave ‘Blue Flame’
8th Lvl Planting Area - Medium
Sesleria autumnalis
Attachment 6
87 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 37
LANDSCAPE SITE PLAN
1/32” = 1’-0”
DN
UP
UP
DN
DN
UP
UP
UP
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 27
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
KEYPLAN
-
xx.xx. 20
# REVIS
AND
LAN
2325
San
415.
KIFER DEVELOPMENT
NOT FOR
1/16" = 1
LIGHTING PL
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
DN
UP
UP
DN
DN
UP
UP
UP
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 27
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO:
SHEET TITLE:
ISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2
# REV
KIFER DEVELOPMENT
NOT FO
1/16" =
LIGHTING P
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
DN
UP
UP
DN
DN
UP
UP
UP
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 27
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
xx.xx. 2023
DATE# REVISION LIST
San Francisco CA 94107
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L801
1/16" = 1'-0"
LIGHTING PLAN
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
LIGHTING PLAN
Attachment 6
88 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 40
SCALE: 3/16” = 1’-0”
SECTION 1: NORTH TOWN HOUSE APPROACH
LANDSCAPE SECTIONS
SECTION 2: NORTH TOWN HOUSE APPROACH - STORMWATER
BUILDING
2'-0"
4'-6"
SIDEWALK
7'-11"
STORMWATERROADWAY
5'-8"
STORMWATER
VARIES 6'-0" TO
8'-0"
TOWNHOUSE
PORCH
NORTH BUILDING
FACADE
12" TO 28"
10'-4"
STORMWATER
4'-6"
SIDEWALK
11'-7"
LOADING ZONE
BUILDING
2'-0"
PROPERTY LINE
Attachment 6
89 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023 41
SECTION 3: SHARED USE PATH SECTION 4: SAN ZENO PLAZA
LANDSCAPE SECTIONS
SCALE: 3/16” = 1’-0”
VINES AT SOUTH
BUILDING FACADE
9'-0"
PLANTING AREA
14'-0"
PERMEABLE
CONCRETE PAVING
SHARED USE PATHWAY
2'-0"
PLANTING
SOUTH PROPERTY
LINE
POLE LIGHT
PL
6'-0"
SIDEWALK
VARIES: 9' TO 19'
ENTRY PLAZA PERMEABLE
UNIT PAVERS
VARIES: 20' TO 27'
EXISTING REDWOOD BERM
SAN ZENO
WAY
PL
EAST PROPERTY
LINE
EAST FACE OF
BUILDING BEYOND
EAST FACE OF
BUILDING
Attachment 6
90 LU SUBMITTAL 05 JULY 05, 2023
LU SUBMITTAL 04 MARCH 2ND, 2023
SECTION 6: BACKFLOW SCREENINGSECTION 5: TRANSFORMER SCREENING FENCE WITH VINES
PROPERTY LINE
10'-3"
GRASSCRETE
20'-0"
CONCRETE PAD
VINES TRAINED ON
U-SHAPE SLAT LOUVER
VERTICAL FENCE
1'-5"
PLANTING
STRIP
4'-6"
SIDEWALK
BUILDING
PAD MOUNT
TRANSFORMER 6'-0"
BUILDING
PROPERTY LINE
BFP - RPDA
HEDGE U-SHAPE SCREEN
29'-3"
PLANTING STRIP
4'-6"
SIDEWALK
9'-8" GROUND COVER
AROUND UTILITIES
2'-10"
HEDGE
SCREENING
16'-9"
GROUND COVER
6'-7"
SIDEWALK
SAN
ZENO
WAY
6'-0"
VISION TRIANGLE
WM
LANDSCAPE SECTIONS
SCALE: 3/16” = 1’-0”
Attachment 6
91 LU SUBMITTAL 05 JULY 05, 2023
ARCHITECTURE
Attachment 6
92 LU SUBMITTAL 05 JULY 05, 2023
10’ 20’ 40’ 80’
SCALE : 1” = 40’
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
EXISITING FIRE
HYDRANT
CL R.O.W.
CL R.O.W.
EXISITING TREES
TRANSFORMERS
PER CIVIL
15' - 0"
10' - 0"
12' - 5" 29' - 5"
10' - 0" SETBACK
15' - 0" SETBACK
SAN
ZEN
O WAY
AMENITY DECK AMENITY DECK
PRIMARY RESIDENTIAL
ENTRY
AMENITY DECK
AMENITY POOL DECKAMENITY COURTYARD
SECONDARY SHARED-USE PATH
397.9'
298.6'
212.3'
NEW TRASH
ENCLOSURE
133.5'
182.6'
40' CORNER VISION TRIANGLE
14' - 0"
SETB
ACK
17' - 11" PRO
POSED
8' - 0"
LOADING SPACE
SITE PLAN 1/20 SCALE
1" = 20'-0"LU36
1 SITE PLAN
N
CB
24" RC
P
24" RC
P
EASEMENTS SEE CIVIL PLANS
CB
24" RC
P
24" RC
P
EASEMENTS SEE CIVIL PLANS
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
PROPERTY LINE
EXISITING FIRE
HYDRANT
CL R.O.W.
CL R.O.W.
EXISITING TREES
TRANSFORMERS
PER CIVIL
15' - 0"
10' - 0"
12' - 5" 29' - 5"
10' - 0" SETBACK 26' - 3"
15' - 0" SETBACK
SAN
ZEN
O WAY
AMENITY DECK AMENITY DECK
PRIMARY RESIDENTIAL
ENTRY
AMENITY DECK
AMENITY POOL DECKAMENITY COURTYARD
SECONDARY SHARED-USE PATH
397.9'
298.6'
212.3'
NEW TRASH
ENCLOSURE
133.5'
182.6'
40' CORNER VISION TRIANGLE
14' - 0"
SETB
ACK
17' - 10" PROPOSED
TYP.
1' - 4"
8' - 0"
50' - 0"
LOADING SPACE
TRASH STAGING ZONE
36' - 0"
10' - 0"
(6) 3-YARD
TRASH/RECYCLING BINS
SHOWN
SITE PLAN 1/20 SCALE
1" = 20'-0"LU87
1 SITE PLAN
N
SITE PLAN
AMENITY COURTYARD AMENITY POOL DECK
RESIDENTIAL WASTE
STAGING AREA
VISUAL FENCE SCREENING
ON SIDES
TRASH STAGING ZONE
10'-0"
20'-0"
27'-0"
Attachment 6
93 LU SUBMITTAL 05 JULY 05, 2023
SCALE : 1/32” = 1’-0”
DN
ELEV 1 & 2
OFFICE PARKING
ELEV 3
UTILITY
1122 SF
MAINTENANCE
486 SF
ELECTRICAL
TRASH
85 STALLS
RAMP
LOBBY
ELEV 4
RR
OFFICE
BOH
PACKAGE
LOBBY
MAIL
PARLOR
BOILER
5' - 9"
70' - 4" 49' - 7" 70' - 4"
3 BED TOWNHOME 3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
70' - 3" 41' - 0" 48' - 8" 11' - 0" 28' - 0" 48' - 10"
LOADING ZONE
OFFICE PARKING
ENTRY
15' - 0" SETBACK
63' - 0"20' - 0"
3' - 8"
24' - 0" 24' - 0"
RAMP
648 SF
TRANSFORMERS
396 SF
ELECTRICAL
UP
137 SF
WATER
397 SF
FIRE PUMP
20' - 0"
526 SF
ELECTRICAL
123 4 5 67 89 10 11 12 13 14 15 16 17
18 19
20 21
22 23 2425 26 2728 2930 3132 33 3435 36 3738 39 40
41 42
43 44
45 54 53 5251 50 4948 47 46 63 62 6160 59 5857 56 55 65 64 77 78 7980 81 8283 84 85 68 69 7071 72 7374 75 76 66 67 15' - 10"66' - 10"
50' - 7" 47' - 1" 62' - 0"
349' - 11"
ELEC
ELEC
24' - 0" 18' - 0" 18' - 0" 24' - 0" 18' - 0"
22' - 8" 20' - 0"
3' - 7"
14' - 1"
18' - 0"
8' - 6"
RESIDENTIAL PARKING
ENTRY
247' - 9"
SETB
ACK
10' - 0"
GATE
60' - 4"
165' - 8"
3' - 8"
3' - 8"
3' - 9"
94' - 4"
26' - 3"
120' - 7"
79' - 3"
GROUND STORY
MARCH 02, 2023 LU88
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU88
1 GROUND STORY
N
GROUND STORY PLAN
8’ 16’ 32’ 64’
1.89 2.89
Attachment 6
94 LU SUBMITTAL 05 JULY 05, 2023
2ND STORY PLANSCALE : 1/32” = 1’-0”
94 STALLS
RAMP
RAMP
WATER ROOM
STORAGE
3 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME
BIKE PARKING
BIKE PARKING
WATER RM
42 UNITS
84 BIKES
128 BIKES
RESIDENTIAL PARKING
12 UNITS
5' - 9"
ELEV 3ELEV 4
ELEV 1 & 2
70' - 3" 41' - 0" 48' - 8" 11' - 0" 28' - 0" 48' - 10"
ACCESS CONTROL
GATE
18' - 0" 24' - 0" 18' - 0" 18' - 0" 24' - 0" 18' - 0"
24' - 0"
BICYCLE REPAIR
65 SF
8' - 6"
ACCESS CONTROL GATE
26' - 3"
94' - 4"
79' - 3"
46' - 3" 14' - 1"
60' - 4"
70' - 4" 49' - 7" 70' - 4" 97' - 8" 62' - 0"
349' - 11"
61' - 9"103' - 4"
165' - 0"
247' - 9"
120' - 7"
STORAGE
2ND STORY
MARCH 02, 2023 LU89
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU89
1 2ND STORY
N
8’ 16’ 32’ 64’
1.89 2.89
Attachment 6
95 LU SUBMITTAL 05 JULY 05, 2023
3RD STORY PLANSCALE : 1/32” = 1’-0”
DOG WASH
STORAGE
STORAGE
(47) 200 CUFT UNITS
(4) 300 CUFT UNITS
(6) 300 CUFT UNITS
RAMP
UTILITY
(16) 200 CUFT UNITS
TRASH
1 BED F 1 BED A1 BED F1 BED F
TRASH
70' - 4" 49' - 7" 70' - 4" 97' - 8" 62' - 0"
ELEV 3ELEV 4
ELEV 1 & 2
2 BED C- 1 BED A 1 BED A2 BED B2 BED B
1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
STUDIO C
123' - 8"
24' - 6"24' - 0"
349' - 11"
62' - 8"102' - 8"
18' - 0" 24' - 0" 18' - 0" 18' - 0" 18' - 0"24' - 0"
165' - 4"
69' - 7" 41' - 9" 87' - 0" 49' - 7"
8' - 6"
90 STALLS
STORAGE
BIKE PARKING
152 BICYCLE STALLS
PARKING
82' - 1"14' - 0"46' - 3"
247' - 11"
60' - 3"
3RD STORY
MAY 24, 2023 LU90
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU90
1 3RD STORY
N
8’ 16’ 32’ 64’
1.89 2.89
Attachment 6
96 LU SUBMITTAL 05 JULY 05, 2023
4TH STORY PLANSCALE : 1/32” = 1’-0”
1619 SF
FITNESS
STUDIO A+
1448 SF
CLUB HOUSE
STUDIO DSTUDIO D
STUDIO A+
1 BED A 1 BED A 1 BED D
STUDIO A+
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
2 BED B
STUDIO C
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
ELEV 3
ELEV 1 & 2
TRASHTRASH
4TH STORY
MARCH 02, 2023 LU91
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU91
1 4TH STORY
N
1619 SF
FITNESS
STUDIO A+
1448 SF
CLUB HOUSE
69' - 8" 41' - 8" 87' - 0" 47' - 5"
STUDIO DSTUDIO D
STUDIO A+
1 BED A 1 BED A 1 BED D
STUDIO A+
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
2 BED B
STUDIO C
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
245' - 9"
ELEV 3
ELEV 1 & 2
19' - 2"
10' - 0"
10' - 0"
13' - 0"
123' - 8"
62' - 4"36' - 7"65' - 9"
69' - 8" 50' - 4" 69' - 8" 98' - 4"
349' - 8"
90' - 9"
164' - 8"
94' - 10"
14' - 0"46' - 0"
60' - 0"
TRASHTRASH
82' - 1"
61' - 9"
4TH STORY
MARCH 02, 2023 LU91
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU91
1 4TH STORY
N
8’ 16’ 32’ 64’
1.89 2.89
Attachment 6
97 LU SUBMITTAL 05 JULY 05, 2023
SCALE : 1/32” = 1’-0”
2 BED D
STUDIO A
SHAFT TRASH TRASHSHAFT ELEV 3
ELEV 1 & 2
1 BED A
2 BED B
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
1 BED A
5TH STORY
JULY 20, 2022 LU41
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU41
1 5TH STORY
N
69' - 8" 41' - 8" 87' - 0" 47' - 5"
94' - 10"
2 BED D
STUDIO A
SHAFT SHAFT ELEV 3
ELEV 1 & 2
1 BED A
2 BED B
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
1 BED A
10' - 0"
10' - 0"
4' - 6"
13' - 0"
5' - 10"
123' - 8"
69' - 8" 50' - 4" 69' - 8"
349' - 8"
98' - 4" 61' - 9"
90' - 9"
62' - 8"36' - 7"65' - 9"
14' - 0"46' - 0"
60' - 0"
165' - 0"
TRASHTRASH
245' - 9"
82' - 1"
5TH STORY
MARCH 02, 2023 LU92
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU92
1 5TH STORY
N
5TH STORY PLAN
8’ 16’ 32’ 64’
1.89 2.89
Attachment 6
98 LU SUBMITTAL 05 JULY 05, 2023
SCALE : 1/32” = 1’-0”
SHAFT TRASH TRASHSHAFT ELEV 3
ELEV 1 & 2
2 BED D
STUDIO A
1 BED A
2 BED F
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED E
2 BED A
2 BED A 2 BED A
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
1 BED A
2 BED G
STUDIO D
2 BED A
6TH STORY
JULY 20, 2022 LU42
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU42
1 6TH STORY
N
69' - 8" 41' - 8" 87' - 0" 47' - 5"
94' - 10"
SHAFT SHAFT ELEV 3
ELEV 1 & 2
2 BED D
STUDIO A
1 BED A
2 BED F
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED E
2 BED A
2 BED A 2 BED A
2 BED C
1 BED B
1 BED A 1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED C 1 BED C+
1 BED A
2 BED G
STUDIO D
2 BED A
10' - 0"
10' - 0"
90' - 9"
65' - 9"
165' - 0"
69' - 8" 50' - 4" 69' - 8" 98' - 3" 61' - 9"
349' - 8"
TRASHTRASH
123' - 8"
14' - 0"46' - 0"
60' - 0"
245' - 9"
82' - 1"
6TH STORY
MARCH 02, 2023 LU93
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU93
1 6TH STORY
N
6TH STORY PLAN
8’ 16’ 32’ 64’
1.89 2.89
Attachment 6
99 LU SUBMITTAL 05 JULY 05, 2023
SHAFT TRASH TRASHSHAFT ELEV 3
ELEV 1 & 2
2 BED D
STUDIO A
1 BED A
2 BED B
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A 1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
1 BED A
2 BED G
STUDIO D
2 BED E
7TH STORY
JULY 20, 2022 LU43
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU43
1 7TH STORY
N
94' - 10"
SHAFT SHAFT ELEV 3
ELEV 1 & 2
2 BED D
STUDIO A
1 BED A
2 BED B
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A
2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A 1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED C 1 BED C+
1 BED A
2 BED G
STUDIO D
2 BED E
10' - 0"
10' - 0"
4' - 5"
90' - 9"
246' - 9"
121' - 11"
69' - 8" 41' - 8" 87' - 0" 48' - 5"
5' - 6"
TRASHTRASH
14' - 5"46' - 0"
60' - 5"
69' - 8" 50' - 4" 69' - 8" 98' - 3" 61' - 9"
349' - 8"
36' - 7"65' - 9"
165' - 0"
81' - 11"
62' - 8"
7TH STORY
MARCH 02, 2023 LU94
170 SAN ZENO WAY
SUNNYVALE, CA 94086
1/16" = 1'-0"LU94
1 7TH STORY
N
7TH STORY PLAN
1.89 2.89
Attachment 6
100
LU SUBMITTAL 05 JULY 05, 2023
CLUB HOUSE
SHAFT TRASH TRASHSHAFT ELEV 3
ELEV 1 & 2
STUDIO A
1 BED A
2 BED B
STUDIO C
STUDIO DSTUDIO D
1 BED A
1 BED A 1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A
2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A 1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED A
STUDIO D
2 BED E
1 BED A
8TH STORY
JULY 20, 2022 LU44
170 SAN ZENO WAY
SUNNYVALE, CA 94086
SCALE : 1/32” = 1’-0”
CLUB HOUSE
94' - 0"
68' - 6" 43' - 1" 85' - 6" 46' - 6"
243' - 6"
ELEV 1 & 2
STUDIO A
1 BED A
2 BED B
STUDIO C
STUDIO D
STUDIO D
1 BED A
1 BED A
1 BED A 1 BED D
1 BED A
1 BED A
1 BED A
1 BED B
1 BED B
1 BED B1 BED B
1 BED B
2 BED A+
2 BED A 2 BED E 2 BED E
2 BED C
1 BED B
1 BED A
1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
1 BED D
2 BED B
STUDIO B
1 BED E
1 BED A
STUDIO D
2 BED E
68' - 3" 52' - 1" 68' - 0" 112' - 10" 36' - 9"
9' - 4"10' - 9"
1 BED A
9' - 4"
10' - 9"
90' - 9"
740 SF
75' - 4"9' - 0"79' - 0"
TRASHTRASH
163' - 4"
12' - 10"
337' - 10"
35' - 7" 18' - 2"
53' - 9"
121' - 11"
81' - 0"
8TH STORY
MARCH 02, 2023 LU95
170 SAN ZENO WAY
SUNNYVALE, CA 94086
8TH STORY PLAN
8’ 16’ 32’ 64’
1.89 2.89
Attachment 6
101
LU SUBMITTAL 05 JULY 05, 2023
163' - 8"
94' - 0"
68' - 8" 43' - 0" 85' - 9" 46' - 4"
68' - 5" 52' - 1" 68' - 0" 112' - 10" 36' - 9"
20' - 1"
243' - 8"
35' - 7" 18' - 2"
53' - 9"
ELEV /
STAIR
OVERRUN
STAIR STAIR
ELEV
RIDGE
RIDGE
RIDGE
HATCH
HATCH
RIDGE
STAIR
RIDGE
RIDGE
RIDGE
RIDGE
RIDGE
RIDGE
RIDGE
RIDGE
90' - 9"
PV PANELS
PV PANELS
PV PANELSPV PANELS
PV PANELS
PV PANELS
PV PANELS
PV PANELS
PV PANELS PV PANELS
PV PANELS PV PANELS
PV PANELS
PV PANELS PV PANELS
MECHANICAL UNITS MECHANICAL UNITS MECHANICAL UNITS MECHANICAL UNITS
MECHANICAL UNITSMECHANICAL UNITS
MECHANICAL UNITS MECHANICAL UNITS
MECHANICAL UNITS
EXHAUST FAN (4FT)
GARAGE EXHAUST
FAN (9FT)
SUPPLY FAN (6FT)
SUPPLY FAN (6FT)
EXHAUST FAN (4FT)
EXHAUST FAN, (4FT)
338' - 1"
77' - 8" 10' - 4" 75' - 8"
5' - 10"
12' - 10" 10' - 7"
20' - 3"
SUPPLY FAN (6FT)
EXHAUST FAN (4FT)
T.O. PARAPET
(2.75FT) TYP.
T.O. PARAPET
(3.5FT) TYP.
UNIT HEAT PUMPS, TYP (2.5FT)
LOUVER SCREEN
(TO MATCH UNIT HEIGHT)
81' - 4"
122' - 11"
ROOF PLAN
MAY 24, 2023 LU96
170 SAN ZENO WAY
SUNNYVALE, CA 94086
SCALE : 1/32” = 1’-0”
SCALE 1/32" = 1'-0"
0 32
KIFER DEVELOPME
PLAN - 4TH LEVEL
ACLA
10.12.2022 ROOF PLAN
8’ 16’ 32’ 64’
1.89 2.89
Attachment 6
102
LU SUBMITTAL 05 JULY 05, 2023
GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
3' - 6"13' - 0"10' - 3"10' - 3"10' - 3"10' - 3"11' - 2"10' - 6"9' - 4" 1' - 2"
88' - 6"
GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
1' - 2" 9' - 4" 10' - 6" 11' - 2" 10' - 3" 10' - 3" 10' - 3" 10' - 3" 13' - 0" 3' - 6" 88' - 6"
BUILDING ELEVATIONS
AUGUST 21, 2022 LU61
170 SAN ZENO WAY
SUNNYVALE, CA 94086
GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
3' - 6"13' - 0"10' - 3"10' - 3"10' - 3"10' - 3"11' - 2"10' - 6"9' - 4"1' - 2" 88' - 6"
GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
88' - 6"
3' - 6"13' - 0"10' - 3"10' - 3"10' - 3"10' - 3"11' - 2"10' - 6"9' - 4"1' - 2"
BUILDING ELEVATIONS
AUGUST 21, 2022 LU60
170 SAN ZENO WAY
SUNNYVALE, CA 94086
BUILDING ELEVATIONS
NORTH ELEVATION
SCALE : 1/32” = 1’-0”
SCALE : 1/32” = 1’-0”
EAST ELEVATION
8’ 16’ 32’ 64’
METAL CANOPIES
SPANDREL PANEL
METAL PANEL
TEXTURED BRICK CLADDING 1 SPANDREL PANEL
STUCCO 2 METAL CANOPY
CEMENT PANEL 3 CEMENT PANEL 1
1.89 METAL PANEL
VINYL WINDOW
BRICK CLADDING 1
GLASS GUARDRAIL
METAL SCREEN
GREENWALL
CEMENT PANEL 2
STEEL RAILING
STOREFRONT
BRICK CLADDING 2
2.89 Attachment 6
103
LU SUBMITTAL 05 JULY 05, 2023
GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
88' - 6"
3' - 6"13' - 0"10' - 3"10' - 3"10' - 3"10' - 3"11' - 2"10' - 6"9' - 4"1' - 2"
BUILDING ELEVATIONS
AUGUST 21, 2022 LU60
170 SAN ZENO WAY
SUNNYVALE, CA 94086
METAL SCREEN
GREENWALL
42 INCH PARAPET
1.89 GROUND STORY
60' - 0"
2ND STORY
69' - 4"
3RD STORY
79' - 10"
4TH STORY
91' - 0"
5TH STORY
101' - 3"
6TH STORY
111' - 6"
7TH STORY
121' - 9"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
PARKING
58' - 10"
3' - 6"13' - 0"10' - 3"10' - 3"10' - 3"10' - 3"11' - 2"10' - 6"9' - 4" 1' - 2"
88' - 6"
8TH STORY
132' - 0"
T.O ROOF
145' - 0"
T.O. PARAPET
148' - 6"
" 13' - 0" 3' - 6"
CEMENT PANEL 1
BUILDING ELEVATIONS
SCALE : 1/32” = 1’-0”
SOUTH ELEVATION
WEST ELEVATION
SCALE : 1/32” = 1’-0”
8’ 16’ 32’ 64’
ROLL-UP DOOR
2.89 CEMENT PANEL 1
Attachment 6
104
LU SUBMITTAL 05 JULY 05, 2023
SCALE : 1/32” = 1’-0”
BUILDING SECTION N-S
BUILDING SECTIONS
1. 2.
SCALE : 1/32” = 1’-0”
BUILDING SECTION E-W
8’ 16’ 32’ 64’ Attachment 6
105
LU SUBMITTAL 05 JULY 05, 2023
ELEVATION DIAGRA
AUGUST 21, 2022 LU1
170 SAN ZENO WAY
SUNNYVALE, CA 94086
MATERIAL PALETTE - NORTH
BRICK CLADDING 2
BRICK CLADDING 2
BRICK CLADDING 1
BRICK CLADDING 1
CEMENT PANEL 1CEMENT PANEL 2STUCCO 2
STUCCO 2METAL CANOPIES METAL CANOPIES
CEMENT PANEL 3 GLASS RAILING
WOOD
STOREFRONT SPANDREL PANEL
STEEL RAILING
METAL PANEL
Attachment 6
106
LU SUBMITTAL 05 JULY 05, 2023
ELEVATION DIAGRAMS
AUGUST 21, 2022 LU20
170 SAN ZENO WAY
SUNNYVALE, CA 94086
STUCCO 2
MATERIAL PALETTE - SOUTH
* WIRE CABLE FOR
* SEE METAL SCREEN GREENWALL FOR ADDITIONAL DETAILS
* WIRE MESH * SEMI-TRANSLUCENT
BRICK CLADDING 1
CLIMBING PLANTSON STEEL FRAME WOVEN WIRE MESH
CEMENT PANEL 3 CEMENT PANEL 2SPANDREL PANEL STEEL RAILINGGLASS RAILINGCEMENT PANEL 1 BRICK CLADDING 1*SPANDREL PANEL
Attachment 6
107
LU SUBMITTAL 05 JULY 05, 2023
MATERIAL BOARD
METAL PANEL - BOX RIB
MATTE BLACK
STUCCO 2- SMOOTH
COLOR TERRACOTTA
SPANDREL PANEL
CHARCOAL
STOREFRONT
BLACK
WINDOWS
BLACK EXTERIOR
CEMENT PANEL
TERRACOTTA
BRICK CLADDING 1
ARCTIC WHITE
CEMENT PANEL
CHARCOAL
BRICK CLADDING 2
CHARCOAL
CEMENT PANEL
COLOR TO MATCH ARCTIC WHITE
UPPER STORIES
LOWER STORIES
Attachment 6
108
LU SUBMITTAL 05 JULY 05, 2023
BEDROOM
LIVING
DINING
KITCHEN
BATH
BALCONY
W/D
CLOSET
24' - 10" 5' - 0"
30' - 9"
10' - 5" 12' - 11"
24' - 2"
BEDROOM 1
BATH 1
STORAGE
BEDROOM 2
LIVING
DINING
KITCHEN
BALCONY
BATH 2
CLOSET
5' - 0"24' - 11"
30' - 8"
10' - 6" 24' - 3"
35' - 7"
5' - 10"
7' - 10"
CLOSET
W/D
BATH
KITCHEN
LIVING
30' - 9"
16' - 8"
DINING
BEDROOM
W/D
BALCONY
UNITS
MARCH 02, 2023 LU103
170 SAN ZENO WAY
SUNNYVALE, CA 94086
UNIT LAYOUT EXAMPLES
STUDIO UNIT 1 BEDROOM UNIT 2 BEDROOM UNIT
SCALE : 1/8” = 1’-0” SCALE : 1/8” = 1’-0” SCALE : 1/8” = 1’-0” Attachment 6
109
LU SUBMITTAL 05 JULY 05, 2023
W
M
W
M
W
M
W
M
TREE #696
TREE #706
TREE #696
TREE #706
RAMP
RAMP
OVERALL SITE PARKING
MARCH 02, 2023 LU104
170 SAN ZENO WAY
SUNNYVALE, CA 94086
OVERALL SITE PARKING
SEE GROUND STORY PARKING SHEET FOR
PARKING IN PROPOSED BUILDING
16 CAR SHARE SPACES (5%) OF NONRESIDENTIAL AND MIXED-USE PARKING 305 STALLS, TO BE IDENTIFIED WITH MARKINGS, SIGNS AS
NECESSARY
EXISTING EV PARKING CHARGING STATIONS, TO REMAIN
15 CLASS II OFFICE BICYCLE PARKING SPACES
29 TOTAL CLASS I OFFICE BICYCLE PARKING SPACES
OFFICE TENANT CURCULATION ROUTE
148 EXISTING STALLS TO REMAIN ON OFFICE PARCEL
Attachment 6
110
LU SUBMITTAL 05 JULY 05, 2023
SCALE : 1/32” = 1’-0”
DN
ELEV 1 & 2
OFFICE PARKING
ELEV 3
UTILITY
MAINTENANCE
ELECTRICAL
TRASH
85 STALLS
RAMP
LOBBY
ELEV 4
RR
OFFICE
BOH
PACKAGE
LOBBY
MAIL
PARLOR
BOILER
TRASH
3 BED TOWNHOME 3 BED TOWNHOME 2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
OFFICE PARKING
ENTRY
RAMP
TRANSFORMERS ELECTRICAL
UP
WATERFIRE PUMP ELECTRICAL
123 4 5 67 89 10 11 12 13 14 15 16 17
18 19
20 21
22 23 2425 26 2728 2930 3132 33 3435 36 3738 39 40
41 42
43 44
45 54 53 5251 50 4948 47 46 63 62 6160 59 5857 56 55 65 64 77 78 7980 81 8283 84 85 68 69 7071 72 7374 75 76 66 67 ELEC
ELEC
24' - 0"18' - 0"8' - 6"
18' - 0" 24' - 0"8' - 6"
24' - 0"
24' - 0"
RESIDENTIAL PARKING
ENTRY
GROUND STORY PARKING
MARCH 02, 2023 LU105
170 SAN ZENO WAY
SUNNYVALE, CA 94086
GROUND STORY PARKING
8’ 16’ 32’ 64’ LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1 LEVEL 2 LEVEL 2
LEVEL 2LEVEL 2
LEVEL 2
LEVEL 2
LEVEL 2
LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2
LEVEL 2 LEVEL 2LEVEL 2
LEVEL 2
LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2LEVEL 2
LEVEL 2
LEVEL 2 LEVEL 2
CLASS 1 BICYCLE PARKING USER ROUTE35% (30) LEVEL 2 - EVCS 65% (55) LEVEL 1 - EV READY SPACE
REACH CODE REQUIREMENTS FOR OFFICE PARKING EV PARKING SPACES, SMC TITLE 16, REACH CODES 85 SHARED PARKING SPACES AT GROUND STORY
*SEE OVERALL PARKING SHEET 109 FOR EXISTING ONSITE PARKING SPACES
OFFICE TENANT CURCULATION ROUTE
OFFICE TENANT CURCULATION ROUTE
OFFICE PARKING / SHARED PARKING
Attachment 6
111
LU SUBMITTAL 05 JULY 05, 2023
94 STALLS
RAMP
RAMP
WATER ROOM
STORAGE
3 BED TOWNHOME 3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
3 BED TOWNHOME
2 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME 3 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME2 BED TOWNHOME
BIKE PARKING
BIKE PARKING
WATER RM
(39) 200 CUFT UNITS
(3) 300 CUFT UNITS
79 BIKES
126 BIKES
RESIDENTIAL PARKING
11 200 CUFT UNITS
1 300 CUFT UNITS
ELEV 3ELEV 4
ELEV 1 & 2
ACCESS CONTROL
GATE
BICYCLE REPAIR
65 SF
12 345 67 8 13 14 15 16 17 18 19 21 20 23
25 26
27 29 30 3132 3334 3536 37 3839 40 4142 43 44
45 54
53 52
6362 61 6059 58 575655 65 64
77 78 798081 8283 84 85
74 75
9 10 11 12 22
24 46
47 48
49 50
51 66 67 68 69 70 71 72 73
86 878889 90 9192
28 93
9' - 0"
18' - 0"
8' - 6"
24' - 0"18' - 0"
24' - 0" 24' - 0"
24' - 0"
76 94
ACCESS CONTROL
GATE
STORAGE
2ND STORY PARKING
MARCH 02, 2023 LU106
170 SAN ZENO WAY
SUNNYVALE, CA 94086
SCALE : 1/32” = 1’-0”
2ND STORY PARKING
8’ 16’ 32’ 64’ CALGREEN EV SPACES (9X18)
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2
LEVEL 2LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2
LEVEL 2LEVEL 2
LEVEL 2LEVEL 2
LEVEL 2LEVEL 2LEVEL 2
LEVEL 2 LEVEL 2
LEVEL 2LEVEL 2 LEVEL 2LEVEL 2
LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2
LEVEL 1 LEVEL 1
LEVEL2 LEVEL 2
CLASS I
CLASS I
CLASS I
REPAIR
REPAIR
CLASS 1 BICYCLE PARKING USER ROUTE
35% (25) LEVEL 2 - EVCS 35% (8) LEVEL 2 - EVCS
205 CLASS I BICYCLE PARKING SPACES
65 SF BICYCLE REPAIR STATION
65% (46) LEVEL 1 - EV READY SPACE 65% (15) LEVEL 1 - EV READY SPACE REACH CODE REQUIREMENTS FOR EV PARKING SPACES, SMC TITLE 16, REACH CODES
OFFICE PARKING / SHARED PARKING RESIDENTIAL PARKING
71 SHARED PARKING SPACES AT SECOND STORY 23 RESIDENTIAL PARKING Attachment 6
112
LU SUBMITTAL 05 JULY 05, 2023
3RD STORY PARKING
DOG WASH
90 STALLS
RAMP
UTILITY
TRASH
1 BED F 1 BED A1 BED F1 BED F
ELEV 3ELEV 4
ELEV 1 & 2
2 BED C- 1 BED A 1 BED A2 BED B2 BED B
1 BED A
1 BED A
1 BED A
2 BED B
2 BED B
STUDIO C
1 2 3 4 56 7 8 13 14 15 16 17 18 19
21 20
23 25
26 27
3032 3334 35 3637 38 394042
43 44
45 54 53 52 63 62 6160 59 5857 56 55 65 64
77 7879 808182 83 8485 7576
9 10 11 12
22 24
46 47
48 49
50 66 67 68 69 70 71 72
86 8788
29 28
3141
51 73
89 9' - 0" 8' - 6"
24' - 0"18' - 0"24' - 0"
18' - 0" 24' - 0"
24' - 6"
74 90
ACCESS CONTROL GATE
TRASH
(6) 300 CUFT UNITS
STORAGE
STORAGE
(16) 200 CUFT UNITS
STORAGE
(16) 200 CUFT UNITS
(46) 200 CUFT UNITS
(4) 300 CUFT UNITS
STORAGE
BIKE PARKING
152 BIKE PARKING
3RD STORY PARKING
MARCH 02, 2023 LU107
170 SAN ZENO WAY
SUNNYVALE, CA 94086
SCALE : 1/32” = 1’-0”
8’ 16’ 32’ 64’ CALGREEN EV SPACES (9X18)
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 RC LEVEL 1 RCLEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 LEVEL 1 RC LEVEL 1 RCLEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1
LEVEL 1 RC LEVEL 1 RC
LEVEL 1LEVEL 1LEVEL 1LEVEL 1 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2LEVEL 2LEVEL 2LEVEL 2 LEVEL 2LEVEL 2LEVEL 2 LEVEL 2 LEVEL 2LEVEL 2 LEVEL 2 LEVEL 1
LEVEL 2 35% (32) LEVEL 2 - EVCS
65% (58) LEVEL 1 - EV READY SPACE
LEVEL 2LEVEL 2 LEVEL 2LEVEL 2LEVEL 2LEVEL 2LEVEL 2 LEVEL 2LEVEL 2
CLASS I
REACH CODE REQUIREMENTS FOR EV PARKING SPACES, SMC TITLE 16, REACH CODES 152 CLASS I BICYCLE PARKING SPACES
Attachment 6
113
LU SUBMITTAL 05 JULY 05, 2023
METAL SCREEN GREENWALL
LINE OF SIGHT
6’-0”
Attachment 6
114
LU SUBMITTAL 05 JULY 05, 2023
METAL SCREEN GREENWALL
WIRE MESH BETWEEN PILASTERS BRICK ON STEEL FRAME
WIRE CABLE FOR CLIMBING PLANTS
SEMI-TRANSLUCENT WOVEN WIRE MESH TO PROVIDE
DAYLIGHT WHILE OBSCURING VIEWS INTO THE PARKING LEVEL
Attachment 6
115
LU SUBMITTAL 05 JULY 05, 2023
ARCHITECTURAL & LANDSCAPE LIGHTING PLAN
LU SUBMITTAL 02 AUGUST 5TH, 202
DRAFT
LANDSCAPE SITE P
1/32” =
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8 " x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
10.06. 2022
DATE# REVISION LIST
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L801
1/16" = 1'-0"
LIGHTING PLAN
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
LIGHTING
LU SUBMITTAL 02 AUGUST 5TH, 2022 37
DRAFT
LANDSCAPE SITE PLAN
1/32” = 1’-0”
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET TITL
ISSUES
PROJECT N
DATE:
SCALE:
KEYPLAN
#
LIGHT
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO
SHEET TI
ISSUES
PROJECT
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
#
LIGH
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
36'-5"
10'-0"
EASEMENTS SEE CIVIL PLANS
LEGEND
SITE LIGHT FIXTURE QTY
VISIONAIRE LIGHTING PREMIER II
PRE-2-L-T2-32LC-3-3K-UNV-PT-SL-DIM-MS,
POLE RNTA4RS-188-15’-AKB-343-T4R-SL,
15’-0” mounting height, single-mount pole, type II,
cast aluminum housing, with silver metallic finish
6 BL LIGHTING
LED LIGHT STRIP UNDER BENCH
24V SD 2400K LED Ribbon
BL-RBN-SD-24V-2400K
3 SELUX
Olivio Medio LED - Floracion Mount - Triple at 120°
STRUCTURA POLE
Bol 16' Round Straight Wood Shaft and Aluminum Base Pole 3 BEGA
LED Garden and Pathway Bollard - 77 263-K3 - 4 3
8" x 27 1
2" 20
WALL SCONCE LIGHTS; CENTERED ON PILASTERS; S.A.D. 24
RECESSED LIGHT; S.A.D. 16
SHEET NO:
SHEET TITLE:
DATEISSUES
PROJECT NO.:
DATE:
SCALE:
All drawings and written material appearing herein constitute original and unpublished work of the Architect/Engineer and may not be duplicated, used or disclosed without consent of Designer.
If this drawing is not 24"x36", then the drawing has been revised from its original size.
Noted scales must be adjusted. This line should be equal to one inch
KEYPLAN
-
10.06. 2022
DATE# REVISION LIST
415.503.0060
170 SAN ZENO WAY
SUNNYVALE, CA 94086
KIFER DEVELOPMENT
NOT FOR CONSTRUCTION
L801
1/16" = 1'-0"
LIGHTING PLAN
BEGA - LED BOLLARD VISIONAIRE - SENSE OF PLACE PLAN REQUIREMENTSELUX LED WITH STRUCTURA POLE - LED FIXTURES
CAN BE DIRECTED DOWN
BL INNOVATIVE LIGHTING - LED STRIP UNDER BENCH
LIGHTING PLAN
BEGA WALL LUMINAIRE
NARROW BEAM DOWNWARD
BEGA DOWNLIGHT
WALL SCONCE LIGHTS RECESSED LIGHT
Attachment 6