Cities Index.
Agenda packet

Turlock City Council
March 24, 2026

Document
Agenda packet
Meeting
March 24, 2026
Body
Turlock City Council
Pages
519
Original file
51.8 MB
Text extracted from the city's file for reading and search. Open the original on turlockca.api.civicclerk.com. That file is the official record.

0045099
Not Required, Elbow, Rear Outlets

0092574
Not Required, Outlet, Rear,
Additional
0085695
Not Required, Elbow, Rear Outlets,
Large, Additional
0092573
Not Required, Outlet, Hose
Bed/Running Board Tray

0752097
Caps/Plugs for 1.00" to 3.00"
Discharges/Inlets, Chain

DISCHARGE CAPS/ INLET PLUGS
Chrome plated, rocker lug, caps with chain will be furnished for all discharge outlets

1.00 " thru

3.00 " in size, besides the pre-connected hose outlets.

Chrome plated, rocker lug, plugs with chain will be furnished for all auxiliary inlets

1.00 " thru

3.00 "
in size.

The caps and plugs will incorporate a thread design to automatically relieve stored pressure in the line when disconnected.
0723042
Valve, 0.75" Bleeder, Discharges, "T"
Swing Handle

OUTLET BLEEDER VALVE
A

0.75 " bleeder valve will be provided for each outlet

1.50 " or larger. Automatic drain valves are
acceptable with some outlets if deemed appropriate with the application.

The valves will be located behind the panel with a T swing style handle control extended to the outside of the side pump panel.

The handles will be chrome plated and provide a visual indication of valve position.

The T swing handle will provide an ergonomic position for operating the valve without twisting the wrist and provides excellent leverage.

Bleeders will be located at the bottom of the pump panel. They will be properly labeled identifying the discharge they are plumbed in to.

The water discharged by the bleeders will be routed below the chassis frame rails. 0029106
Not Required, Deluge Outlet
0029302
No Monitor Requested

0029304
No Nozzle Req'd

0029107
No Deluge Mount

0029167
Crosslays Sngl Sheet Unpainted,
(2+) 1.50", Std. Cap

CROSSLAY HOSE BEDS
Two (
2 ) crosslays
with

1.50 " outlets will be provided. Each bed to be capable of carrying 200
' of

1.75 " double jacketed hose and will be plumbed with

2.00 " i.d. pipe and gated with a

2.00 "
quarter turn ball valve.

Outlets to be equipped with a

1.50 " National Standard hose thread
90 degree swivel located in
the hose bed so that hose may be removed from either side of apparatus.

The crosslay controls will be at the pump operator's panel.

The center crosslay dividers will be fabricated of

0.25 " aluminum and will provide adjustment from
side to side. The divider will be unpainted with a brushed finish.

Vertical scuffplates constructed of polished stainless steel will be provided at the front and rear ends of the bed on each side of vehicle.

Crosslay bed flooring will consist of removable perforated brushed aluminum. 0029196
Not Required, 2.50" Crosslay

0591145
Hose Restraint, Crosslay/Deadlay,
Top/Ends, Elastic Netting

CROSSLAY/DEADLAY HOSE RESTRAINT
Elastic netting will be provided across the top and ends of two (
2 )
crosslay/deadlay opening(s) to
secure the hose during travel. The netting will be permanently attached at the top center of the crosslay/deadlay bed and removable on each end.
0029260
Not Required, Speedlays

0750536
Hose Restr, Spdly, Not Required, No
Spdly
60 989
Bid #:

Page 381 of 519 ends

0044333
Not Required, Foam System

FOAM SYSTEM
A foam system will not be required on this apparatus.
0012126
Not Required, CAF Compressor

0552517
Not Required, Refill, Foam Tank
0042573
Not Required, Foam System
Demonstration

0045465
Not Required, Foam Tanks
0091110
Not Required, Foam Tank Drain
0091079
Not Required, Foam Tank #2

0091112
Not Required, Foam Tank #2 Drain

0738072
Approval Dwg, Pump Panel(s), Not
Required
0035570
Pump Panel Configuration, No Match
Required

PUMP PANEL CONFIGURATION
The pump panel configuration will be neat and orderly.
0562698
Step, Slide-Out/Fold-Out, Pump
Operator Platform, Aerial

PUMP OPERATOR'S PLATFORM
A pull out, flip down platform will be provided at the pump operator's control panel.

The front edge and the top surface of the platform will be made of DA finished aluminum with a Morton Cass insert.

The platform will be approximately

13.75 " deep when in the stowed position and approximately

22.00 " deep when extended. The platform stepping surface will be

35.00 " wide. The platform will
lock in the retracted and the extended position.

The sides, bottom and rear portions of the support assembly will be painted to match lower job color.

The platform will be wired to the "step not stowed" indicator in the cab. 0667186
Light, Slide-Out Pump Operator Step,
OSS Access LED, Short Step

PUMP OPERATOR'S PLATFORM PERIMETER LIGHT
There will be an On Scene Solutions, Model Night Stick Access,

20.00 " white
12 volt DC LED
strip light provided to illuminate the ground area.
0629252
Material, Pump Panels, Side Control
Black Vinyl

PUMP AND GAUGE PANEL
The pump and gauge panels will be constructed of
aluminum
with a
black vinyl
finish. A polished
aluminum trim molding will be provided around each panel. 0721765
Panel, Pump Access - Right Side
Only, Side Control

PUMP ACCESS
Right Side Panel
The right side upper pump panel will be removable.

Panel Fastener
The removable panels will be secured with
black swell latch
.

The left side pump panels will be attached with screws.

The right side lower pump panel (drain bank) will be attached with screws. 0583824
Light, Pump Compt, Wln 3SC0CDCR
LED White

PUMP COMPARTMENT LIGHT
There will be
two (
2 )
Whelen®, Model
3 SC
0 CDCR,

3.00 " white
12 volt DC LED light(s) with
Whelen, Model
3 FLANGEC, flange(s) installed in the pump compartment. 0536401
Gauges, Engine, Included With
Pierce Pressure Controller

Engine monitoring graduated LED indicators will be incorporated with the pressure controller. 0005601
Throttle, Engine, Incl'd w/Press
Controller
61 989
Bid #:

Page 382 of 519 ends

0739224
Indicator Light @ Pump Panel,
Throttle Ready, Incl w/Pressure
Gov/Throttle,Green

THROTTLE READY GREEN INDICATOR LIGHT
There will be a green indicator light integrated with the pressure governor and/or engine throttle installed on the pump operators panel that is activated when the pump is in throttle ready mode. 0549333
Indicators, Engine, Included with
Pressure Controller
0745568
Indicator Light, Pump Panel, Ok To
Pump, Green

OK TO PUMP INDICATOR LIGHT
There will be a green indicator light installed on the pump operators panel that is activated when the pump is in Ok To Pump mode.
0511078
Gauges, 4.00" Master, Class 1, 30"-0
-600psi

VACUUM AND PRESSURE GAUGES
The pump vacuum and pressure gauges will be liquid filled and manufactured by Class 1 Incorporated.

The gauges will be a minimum of

4.00 " in diameter and will have white faces with black lettering, with a pressure range of

30.00 "-
0-600#
.

Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded retaining nut.

The pump pressure and vacuum gauges will be installed adjacent to each other at the pump operator's control panel.

Test port connections will be provided at the pump operator's panel. One ( 1 ) will be connected to
the intake side of the pump, and the other to the discharge manifold of the pump. They will have

0.25 in. standard pipe thread connections and non-corrosive polished stainless steel or brass plugs. They will be marked with a label.

This gauge will include a
10 year warranty against leakage, pointer defect, and defective bourdon tube.
0511100
Gauge, 2.00" Pressure, Class 1, 30"-
0-400psi

PRESSURE GAUGES
The individual "line" pressure gauges for the discharges will be Class 1 interlube filled.

They will be a minimum of

2.00 " in diameter and have white faces with black lettering.

Gauge construction will include a Zytel nylon case with adhesive mounting gasket and threaded retaining nut.

Gauges will have a pressure range of
30 "-
0-400#
.

The individual pressure gauge will be installed as close to the outlet control as practical.

This gauge will include a
10 year warranty against leakage, pointer defect, and defective bourdon tube.
0750526
Gauge, Water Level, Pierce, In
pressure Controller, Lt Driver

WATER LEVEL GAUGE
An electric water level gauge will be incorporated in the pressure controller that registers water level by means of nine (
9 ) LEDs. They will be at
1/8
level increments with a tank empty LED. The
LEDs will be a bright type that is readable in sunlight and have a full 180
-degree of clear viewing.

To further alert the pump operator, the gauge will have a warning flash when the tank volume is less than
25 percent. The gauge will have down chasing LEDs when the tank is almost empty.

The level measurement will be ascertained by sensing the head pressure of the fluid in the tank or cell.

There will be a light driver module with this installation to power additional water level gauge(s) included on the apparatus.
0006774
Not Required, Foam Level Gauge
0593161
Light Shield, S/S LED

LIGHT SHIELD
There will be a polished,
16 gauge stainless steel light shield installed over the pump operator's panel.

There will be
12 volt DC white LED lights installed under the stainless steel light shield to illuminate the controls, switches, essential instructions, gauges, and instruments necessary for the operation of the apparatus. These lights will be activated by the pump panel light switch.

Additional lights will be included every

18.00 " depending on the size of the pump house.

One (
1 ) pump panel light will come on when the pump is in ok to pump mode.

The switch panel will be lit when the parking brake is set. This is to afford the operator illumination when first approaching the control panel.
0606694
Air Horns, (2) Hadley, 6" Round,
eTone, In Bumper

AIR HORN SYSTEM
Two (
2 ) Hadley®, eTone, chrome air horns will be recessed in the front bumper. The air horn system will be piped to the air brake system wet tank utilizing

0.38 " tubing. A pressure protection
valve will be installed to prevent the loss of air in the brake system. 0606832
Location, Air Horns, Bumper, Left
Side, Outside Frame, (Pos #6 & #7)
Air Horn Location
The air horns will be located on the left side of the bumper, outside of the frame rail. 0757092
Control, Air Horn, Multi Select

Air Horn Control
The air horn(s) will be activated by the following:
62 989
Bid #:

Page 383 of 519 ends

0757078
Control, Air Horn, Push Button Sw,
RS
Right side push button switch
0743360
Control, Air Horn, Ft Sw, LS, Location
Fet
Left side foot switch will be
To the left of Mechanical siren foot switch. Match 38759 .
0534828
Siren, Wln 295SL101, 100 or 200W
Removable Mic

ELECTRONIC SIREN
There will be a Whelen, Model
295
SL
101
,
100
or
200
watt electronic siren with noise canceling
plug-in microphone will be provided.

This siren to be active when the battery switch is on and that emergency master switch is on. 0510206
Location, Elect Siren, Recessed
Overhead In Console

Electronic siren head will be
recessed in the driver side center switch panel
.
0076157
Control, Elec Siren, Horn Ring

SIREN CONTROL
The electronic siren will be controllable on the siren head and horn ring only. No foot switches will be required.

The driver will have the option to control the siren or the chassis horns from the horn button by means of a selector switch located on the instrument panel. 0649097
Speaker, (1) Wln, SA315P, w/Pierce
Painted Job Color Grille, 100 watt

SPEAKER
There will be one (
1 ) Whelen, Model SA
315
P, black nylon composite,
100
-watt, speaker with
through bumper mounting brackets and painted grille provided. The speaker will be connected to
the siren amplifier
.
0601551
Location, Speaker, Frt Bumper,
Recessed, Right Side, Outside
Frame,Outbrd(Pos 1)
The speaker will be recessed in the right side of the front bumper, towards the outside. 0895281
Siren, Federal Q2B, Littelfuse 24213
Sol

AUXILIARY MECHANICAL SIREN
There will be a Federal Signal Model Q
2 B mechanical siren furnished and installed in the front of the apparatus.

The Q
2 B siren will be
chrome finish
.

The siren will have a
2 -gauge cable connected to a Littelfuse part number
24213
power solenoid
that is connected by a
2 -gauge cable ran battery direct to the primary chassis batteries and will be labeled Q
2 B+ at the battery. The power solenoid will only be enabled when the emergency master switch is on.

The siren will have a
2 -gauge ground wire connected to the chassis battery stud. The cable will be labeled Q
2 B- at the battery.
0578974
Siren, Mechanical, Recessed In
Grille, Imp/Vel
The mechanical siren will be mounted recessed in the front grille. The siren mounting will include a reinforcement plate.
0748305
Control, Mech Siren, Multi Select

MECHANICAL SIREN CONTROL
The mechanical siren will be activated by the following:
0748279
Control Mech Siren, Push Button Sw,
RS
Right side push button switch
0748282
Control Mech Siren, Ft Sw LS
Left side foot switch.
0736165
Sw, Siren Brake, Momentary, RS
Overhead Sw Pnl

A momentary switch will be included in the right side overhead switch panel to activate the siren brake.
0736649
Sw, Siren Brake, Momentary Red,
Center Console Sw Pnl

A momentary red switch will be included on the center console switch panel to activate the siren brake.
0776528
SP
Grille, Speaker, Front Bumper,S/S,
Painted

SPEAKER GRILLE
There will be
one (
1 )
painted stainless steel grille(s) provided, one (
1 ) over each siren speaker in
the front bumper. The grille(s) and bumper will be the same color. 0746353
Not Required, Warning Lights
Intensity
63 989
Bid #:

Page 384 of 519 ends

0604784
Lightbar, Wln, Freedom IV-Q, 81",
RRRRWRsrROptRsrRWRRRR

FRONT ZONE UPPER WARNING LIGHTS
There will be one (
1 )

81.00 " Whelen® Freedom IV
™
lightbar mounted on the cab roof.

The lightbar will include the following:

One (
1 ) red flashing LED module in the driver's side end position.

One (
1 ) red flashing LED module in the driver's side front corner position.

One (
1 ) red flashing LED module in the driver's side first front position.

One (
1 ) red flashing LED module in the driver's side second front position.

One (
1 ) white flashing LED module in the driver's side third front position.

One (
1 ) red flashing LED module in the driver's side fourth front position.

One (
1 ) red steady burning LED module in the driver's side fifth front position.

One (
1 ) red flashing LED module in the driver's side sixth front position.

One (
1 )
795
LED traffic light controller set to
national standard high priority
in the center positions.

One (
1 ) red flashing LED module in the passenger's side sixth front position.

One (
1 ) red steady burning LED module in the passenger's side fifth front position.

One (
1 ) red flashing LED module in the passenger's side fourth front position.

One (
1 ) white flashing LED module in the passenger's side third front position.

One (
1 ) red flashing LED module in the passenger's side second front position.

One (
1 ) red flashing LED module in the passenger's side first front position.

One (
1 ) red flashing LED module in the passenger's side front corner position.

One (
1 ) red flashing LED module in the passenger's side end position.

There will be
clear lenses and colored filters included on the lightbar .

The following switches may be a installed in the cab on the switch panel to control the lightbar:
a switch to control the flashing LED modules.
the traffic light controller
by a cab switch with emergency master control
.
no momentary switch to activate the traffic light controller .

The white flashing LED modules and the traffic light controller will be disabled when the parking brake is applied.

The eight (
8 ) red flashing LED modules in the front positions may be load managed when the parking brake is applied.
0641379
Bracket, Lightbar, Forward Offset,
Custom

LIGHTBAR MOUNTING BRACKETS
There will be a pair of lightbar mounting brackets that will move the lightbar forward of the normal position on the cab roof. These brackets will be made of 12 gauge steel and painted black.
0540439
Light, Front Zone, Wln M6* LED,
Colored Lens 2Lts
WARNING LIGHTS (Cab Face)
Two (
2 ) Whelen model M
6 * LED flashing warning lights with chrome flange will be provided on the front of the cab above the headlights.

The
driver's side front warning light to be red
.

The
passenger's side front warning light to be red
.

Both lights will include a lens that is the same color as the LED's.

There will be a switch located in the cab, on the switch panel, to control the lights. 0653937
Flasher, Headlight Alternating

HEADLIGHT FLASHER
The high beam headlights will flash alternately between the left and right side.

There will be a switch installed in the cab on the switch panel to control the high beam flash. This switch will be live when the battery switch and the emergency master switches are on.

The flashing will automatically cancel when
the hi-beam headlight switch is activated
or when the
parking brake is set.
0747228
Lights, Side Zone Lower, Wln M6**,
M6**, M6**, 6Lts

SIDE ZONE LOWER LIGHTING
There will be six (
6 ) Whelen®, Model M
6 **,

4.31 " high x

6.75 " long x

1.37 " deep flashing LED
warning lights with
black trim
installed per the following:

Two (
2 ) lights located,
one (
1 ) each side on the front custom cab corner
. The
driver's side, side
front light to include red warning LEDs
and the
passenger's side, side front light to include blue
warning LEDs
.

Two (
2 ) lights located,
one (
1 ) each side of cab rearward of crew cab doors
. The
driver's side,
side middle light to include red warning LEDs
and the
passenger's side, side middle light to
include red warning LEDs
.

Two (
2 ) lights located,
one (
1 ) each side, just rearward of the rear wheels
. The
driver's side, side
rear light to include red warning LEDs
and the
passenger's side, side rear light to include red
warning LEDs
.

The
warning light lens colors to be the same as the LEDs
.

There will be a switch in the cab on the switch panel to control the lights. 0895974
Lights, Door Interior Flash, 4 Dr Cab,
Wln 3S*00F*R, 3" Round

INTERIOR CAB DOOR WARNING LIGHTS
There will be four (
4 ) Whelen® Model
3 S*
00 F*R,

3.00 " round deep flashing LED warning lights
with
chrome trim
.

One (
1 )
light(s) to include red flashing LED's
on the left side cab door
One (
1 )
light(s) to include red flashing LED's
on the right side cab door.

One (
1 )
light(s) to include red flashing LED's
on the right side crew cab door.

One (
1 )
light(s) to include red flashing LED's
on the left side crew cab door.

The
lens color(s) to be the same as the LEDs
.

Each light will be
located in the door pan as low and far to the outside as practical .

Each light will be activated when the battery switch is on, respective door is opened and no other
controls are on
.
64 989
Bid #:

Page 385 of 519 ends

0815847
Connectors, Door Interior Flash, All
Cabs, Weatherproof

ELECTRICAL CONNECTORS FOR WARNING LIGHTS
The lights will be installed with a weatherproof insulated crimped connectors in order to provide ease of connection/disconnection of the circuit applied to. 0750408
Lights, Side, Wln PS*01FCR, 1st

SIDE WARNING LIGHTS
There will be
ten (
10 )
Whelen® Model PS*
01 FCR,

1.68 " high x

11.11 " wide x

0.52 " deep flashing
LED warning light(s) with
chrome trim
and clear lenses provided on the side of the apparatus, 1 )
Centered in rub rail Below RS
1 ,
1 ) Centered in rub rail below LS
1 ,
1 ) Centered in rub rail below
RS
5 ,
1 ) Centered in rub rail below LS
3 ,
1 ) Centered in rub rail below LS
5 ,
1 ) Centered in rub rail
below RS
7 ,
1 ) Centered in rub rail below RS
9 ,
1 ) Cente
.

The
light(s) to include red flashing LEDs
.

These lights will be controlled by the side zone lower switch in the cab.

White LEDs will be deactivated when the parking brake is applied.

Amber, blue, green and red LEDs may be load manages when the parking brake is applied. 0564654
Lights, Rear Zn Lwr, Wln M6*,
Colored Lens, For Tail Light Housing

REAR ZONE LOWER LIGHTING
There will be two (
2 ) Whelen®, Model M
6 *, LED flashing warning lights will be located at the rear of the apparatus.

The
driver's side rear light to be red
The
passenger's side rear light to be red
Both lights will include a lens that is the same color as the LED's.

There will be a switch located in the cab on the switch panel to control the lights. 0621947
Light, Rear Zone Up, Wln Rota-Beam
R316*F LED Beacon, Color Lens

REAR OF HOSE BED WARNING LIGHTS
There will be two (
2 ) Whelen® Rota-Beam
™,
Model R
316
*F,

4.00 " high x

7.19 " wide beacons
with the same color domes as the LEDs provided.

The
rear zone upper light(s) to be red in color
.

There will be a switch located in the cab on the switch panel to control the beacons. 0006551
Not Required, Lights, Rear Upper
Zone Blocking
0791528
Light, Traffic Directing, Wln TAL65,

36.00" Long, TACTL5

TRAFFIC DIRECTING LIGHT
There will be one (
1 ) Whelen®, Model TAL
65 ,

36.00 " long x

2.87 " high x

2.25 " deep, amber LED
traffic directing light installed at the rear of the apparatus.

The Whelen, Model TACTL
5 , control head will be included with this installation.

The controller will be energized when the battery switch is on.

The
auxiliary flash to be activated when the emergency master switch is on .
0529278
Location, TDL, Surface Mounted
This traffic directing light will be surface mounted at the rear of the apparatus. 0530282
Location, Traf Dir Lt Controller,
Overhead Switch Panel DS Right
End
The traffic directing light control head will be located in the driver side overhead switch panel in the right panel position.
0006646
Electrical System, 120/240VAC,
General Design
ELECTRICAL SYSTEM GENERAL DESIGN for ALTERNATING CURRENT The following guidelines will apply to the
120/240
VAC system installation:

General
Any fixed line voltage power source producing alternating current (ac) line voltage will produce electric power at
60 cycles plus or minus
3 cycles.

Except where superseded by the requirements of the current edition of applicable NFPA standards, all components, equipment and installation procedures will conform to NFPA 70 ,
National Electrical Code (herein referred to as the NEC).

Line voltage electrical system equipment and materials included on the apparatus will be listed and installed in accordance with the manufacturer's instructions. All products will be used only in the manner for which they have been listed.

Grounding
Grounding will be in accordance with Section
250-6
"Portable and Vehicle Mounted Generators"
of the NEC. Ungrounded systems will not be used. Only stranded or braided copper conductors will be used for grounding and bonding.

An equipment grounding means will be provided in accordance with Section 250-91
(Grounding
Conductor Material) of the NEC.

The grounded current carrying conductor (neutral) will be insulated from the equipment grounding conductors and from the equipment enclosures and other grounded parts. The neutral conductor will be colored white or gray in accordance with Section 200-6
(Means of Identifying Grounding
Conductors) of the NEC.

In addition to the bonding required for the low voltage return current, each body and driving or crew compartment enclosure will be bonded to the vehicle frame by a copper conductor. This conductor will have a minimum amperage rating of
115
percent of the nameplate current rating of
the power source specification label as defined in Section 310-15
(amp capacities) of the NEC. A
single conductor properly sized to meet the low voltage and line voltage requirements will be permitted to be used.

All power source system mechanical and electrical components will be sized to support the continuous duty nameplate rating of the power source.

Operation
Instructions that provide the operator with the essential power source operating instructions, including the power-up and power-down sequence, will be permanently attached to the apparatus 65 989
Bid #:

Page 386 of 519 ends

at any point where such operations can take place.

Provisions will be made for quickly and easily placing the power source into operation. The control will be marked to indicate when it is correctly positioned for power source operation. Any control device used in the drive train will be equipped with a means to prevent the unintentional movement of the control device from its set position.

A power source specification label will be permanently attached to the apparatus near the operator's control station. The label will provide the operator with the following information:

Rated voltage(s) and type (ac or dc)
Phase
Rated frequency
Rated amperage
Continuous rated watts
Power source engine speed
Direct drive (PTO) and portable generator installations will comply with Article 445
(Generators) of
the NEC.

Overcurrent protection
The conductors used in the power supply assembly between the output terminals of the power source and the main over current protection device will not exceed 144.00
" (
3658
mm) in length.

For fixed power supplies, all conductors in the power supply assembly will be type THHW, THW, or use stranded conductors enclosed in nonmetallic liquid tight flexible conduit rated for a minimum of
194
degree Fahrenheit (
90 degrees Celsius).

For portable power supplies, conductors located between the power source and the line side of the main overcurrent protection device will be type SO or type SEO with suffix WA flexible cord rated for
600
-volts at
194
degrees Fahrenheit (
90 degrees Celsius).

Wiring Methods
Fixed wiring systems will be limited to the following:

Metallic or nonmetallic liquid tight flexible conduit rated at not less than 194
degrees Fahrenheit
(
90 degrees Celsius)
or
Type SO or Type SEO cord with a WA suffix, rated at
600
volts at not less than
194
degrees
Fahrenheit (
90 degrees Celsius)
Electrical cord or conduit will not be attached to chassis suspension components, water or fuel lines, air or air brake lines, fire pump piping, hydraulic lines, exhaust system components, or low voltage wiring. In addition the wiring will be run as follows.

Separated by a minimum of

12.00 " (
305
mm), or properly shielded, from exhaust piping
Separated from fuel lines by a minimum of

6.00 " (
152
mm) distance
Electrical cord or conduit will be supported within

6.00 " (
152
mm) of any junction box and at a
minimum of every

24.00 " (
610
mm) of continuous run. Supports will be made of nonmetallic materials or corrosion protected metal. All supports will be of a design that does not cut or abrade the conduit or cable and will be mechanically fastened to the vehicle.

Wiring Identification
All line voltage conductors located in the main panel board will be individually and permanently identified. The identification will reference the wiring schematic or indicate the final termination point. When prewiring for future power sources or devices, the unterminated ends will be labeled showing function and wire size.

Wet Locations
All wet location receptacle outlets and inlet devices, including those on hardwired remote power distribution boxes, will be of the grounding type provided with a wet location cover and installed in accordance with Section
210-7
"Receptacles and Cord Connections" of the NEC.

All receptacles located in a wet location will be not less than

24.00 " (
610
mm) from the ground.

Receptacles on off-road vehicles will be a minimum of

30.00 " (
762
mm) from the ground.

The face of any wet location receptacle will be installed in a plane from vertical to not more than 45 degrees off vertical. No receptacle will be installed in a face up position.

Dry Locations
All receptacles located in a dry location will be of the grounding type. Receptacles will be not less than

30.00 " (
762
mm) above the interior floor height.

All receptacles will be marked with the type of line voltage ( 120
-volts or
240
-volts) and the current
rating in amps. If the receptacles are direct current, or other than single phase, they will be so marked.

Listing
All receptacles and electrical inlet devices will be listed to UL 498
, Standard for Safety
Attachment Plugs and Receptacles, or other appropriate performance standards. Receptacles used for direct current voltages will be rated for the appropriate service.

Electrical System Testing
The wiring and associated equipment will be tested by the apparatus manufacturer or the installer of the line voltage system.

The wiring and permanently connected devices and equipment will be subjected to a dielectric voltage withstand test of
900
-volts for one (
1 ) minute. The test will be conducted between live
parts and the neutral conductor, and between live parts and the vehicle frame with any switches in the circuit(s) closed. This test will be conducted after all body work has been completed.

Electrical polarity verification will be made of all permanently wired equipment and receptacles to determine that connections have been properly made.

Operational Test per Current Edition NFPA Standard
The apparatus manufacturer will perform the following operation test and ensure that the power source and any devices that are attached to the line voltage electrical system are properly connected and in working order. The test will be witnessed and the results certified by an independent third-party certification organization.

The prime mover will be started from a cold start condition and the line voltage electrical system loaded to
100
percent of the nameplate rating.

The power source will be operated at
100
percent of its nameplate voltage for a minimum of two
(
2 ) hours unless the system meets category certification as defined in the current edition of applicable NFPA standards.

Where the line voltage power is derived from the vehicle's low voltage system, the minimum continuous electrical load as defined in the current edition of applicable NFPA standards will be applied to the low voltage electrical system during the operational test. 66 989
Bid #:

Page 387 of 519 ends

0649150
Generator, Harrison 10kW Hydraulic,
Hot Shift PTO, IHT System

HYDRAULIC GENERATOR
There will be one (
1 ) Harrison

10.0 kW hydraulic single phase
60 Hz
120/240
volt AC generator
provided.

An electrical instrument gauge panel will be provided for the operator to monitor and control all electrical operations and output. The meter and indicators will be installed near eye level in a compartment. Instruments will be flush mounted in an appropriate sized weatherproof electrical enclosure.

The hydraulic engagement supply will be operational
at any time (no interlocks)
.

There will be two (
2 ) hydraulic loads driven by a transmission power take off unit (PTO) through a Harrison Integrated Hydraulic Technologies (IHT) valve system. This system will include a function manifold to direct the hydraulic fluid from the PTO to the following circuits:

The first hydraulic circuit to be the

10.0 kW generator.

The second hydraulic circuit to be
provided for the Holmotro tool system
.

There will be a switch located
next to the captive rollers on the hydraulic reels
to activate the
second hydraulic circuit.
0505796
Location, Hydraulic Generator Above
Gooseneck of Tiller

GENERATOR LOCATION
The generator will be mounted in the area above the goose neck of the tiller trailer. The flooring in this area will be either reinforced or constructed, in such a manner, that it will handle the additional weight of the generator.
0658370
Starting Sw, Truck Engine Powered
Gen, Cab Sw Pnl, Tiller Cab

GENERATOR START
There will be a switch located on the cab instrument panel to engage the generator.

There will be another switch located in the tiller cab on the instrument panel to engage the same generator.
0732223
SP
Remote Start, Hydraulic Generator, 4
Locations

GENERATOR REMOTE START
There will be a generator remote start/stop switch with indicator light in the following locations:
within reach of the officer switch panel
.

Generator control station in LS
7 .

Tied to Aerial Master Switch
.
within reach of the drivers switch panel
.
0016740
Not Required, Fuel System
0016767
Not Required, Oil Drain Extension,
Generator
0006738
Circuit Breaker Panel w/Generator

CIRCUIT BREAKER PANEL
A circuit breaker panel will be installed in the
D
7 mounted on a partition that faces straight out the
door for easy access
. A directory for each breaker will be provided adjacent to the circuit breaker panel. Identification of circuits will be done in a durable manner that provides years of service. 0095290
Cover, Generator & Hyd Res, On
Gooseneck (Tiller)

HYDRAULIC GENERATOR COVER
The hydraulic generator and reservoir will be covered on the front and two sides with bright aluminum treadplate. The top and rear will not be covered. The cover will be attached to the gooseneck. The cover will be louvered as required to provide adequate ventilation and be removeable for maintenance of the generator. Protective edging will be provided along the top edge of the cover.
0016771
Not Required, Routing Exhaust,
Generator
0779717
Receptacle, 15/20A 120V 3-Pr 3-Wr,
NEMA 5-20R SB Dup, 3rd, Interior
Body
120

VOLT RECEPTACLE
There will be
one (
1 )
,
15/20
amp
120
volt AC three (
3 ) wire straight blade duplex receptacle(s)
with
an interior flip up cover
, installed
LS
4 - TBD at preconstruction
. The NEMA configuration for
the receptacle(s) will be
5-20
R.

The receptacle(s) will be powered from the
onboard generator to shoreline power transfer switch
.

There will be a label installed near the receptacle(s) that state the following:

Line Voltage
Current Ratting (amps)
Phase
Frequency
67 989
Bid #:

Page 388 of 519 ends

0779718
Receptacle, 15/20A 120V 3-Pr 3-Wr,
NEMA 5-20R SB Dup, 2nd, Interior
Body
120

VOLT RECEPTACLE
There will be
one (
1 )
,
15/20
amp
120
volt AC three (
3 ) wire straight blade duplex receptacle(s)
with
an interior flip up cover
, installed
RS
6 - Location TBD at preconstruction
. The NEMA
configuration for the receptacle(s) will be
5-20
R.

The receptacle(s) will be powered from the
onboard generator to shoreline power transfer switch
.

There will be a label installed near the receptacle(s) that state the following:

Line Voltage
Current Ratting (amps)
Phase
Frequency
0779722
Receptacle, 15/20A 120V 3-Pr 3-Wr,
NEMA 5-20R SB Dup, 1st, Interior
Body
120

VOLT RECEPTACLE
There will be
one (
1 )
,
15/20
amp
120
volt AC three (
3 ) wire straight blade duplex receptacle(s)
with
an interior duplex flip up cover
, installed
RS
8 - Exact location at preconstruction
. The NEMA
configuration for the receptacle(s) will be
5-20
R.

The receptacle(s) will be powered from the
onboard generator to shoreline power transfer switch
.

There will be a label installed near the receptacle(s) that state the following:

Line Voltage
Current Ratting (amps)
Phase
Frequency
0519934
Not Required, Brand, Hydraulic Tool
System
0649753
Not Required, PTO Driven Hydraulic
Tool System
0649748
Not Required, Hydraulic Hose

0755072
Aerial, 107' ASL, 750/500 Tip, 50
MPH Wind, Tiller
FOUR (
4 )-SECTION
107

FOOT TRACTOR-DRAWN AERIAL LADDER

CONSTRUCTION STANDARDS
The ladder will be constructed to meet all of the requirements as described in the current edition of applicable NFPA standards.

The aerial device will be a true ladder type device.

These capabilities will be established in an unsupported configuration.

All structural load supporting elements of the aerial device that are made of a ductile material will have a design stress of not more than
50 percent of the minimum yield strength of the material based on the combination of the live load and the dead load. This 2:1
structural safety factor
meets the current NFPA standard.

All structural load supporting elements of the aerial device that are made of non-ductile material will have a design stress of not more than
20 percent of the minimum ultimate strength of the
material, based on the combination of the rated capacity and the dead load. This 5:1
safety factor
meets the current NFPA standard.

Wire ropes and attaching systems used to extend and retract the fly sections will have a 5:1

safety factor based on the ultimate strength under all operating conditions. The factor of safety for the wire rope will remain above
2:1
during any extension or retraction stall. The minimum ratio of the diameter of wire rope used to the diameter of the sheave used will be 1:12
. Wire ropes will be
constructed of seven (
7 ) strands over an inner wire core for increased flexibility. The wire rope will be galvanized to reduce corrosion.

The aerial base pivot bearings will be maintenance free type bearings and require no external lubrication.

The aerial device will be capable of sustaining a static load one and one-half times its rated tip load capacity (live load) in every position in which the aerial device can be placed when the vehicle is on a firm level surface.

The aerial device will be capable of sustaining a static load one and one-third times its rated tip load capacity (live load) in every position the aerial device can be placed when the vehicle is on a slope of five degrees downward in the direction most likely to cause overturning.

With the aerial device out of the cradle and in the fully extended position at zero degrees elevation, a test load will be applied in a horizontal direction normal to the centerline of the ladder.

The turntable will not rotate and the ladder will not deflect beyond what the product specification allows.

All welding of aerial components, including the aerial ladder sections, turntable, pedestal, and outriggers, will be in compliance with the American Welding Society standards. All welding personnel will be certified, as qualified under AWS welding codes.

The aerial device will be capable of operating in conditions of wind up to 50 mph and icing
conditions of up to a

0.25 " coating over the aerial structure.

All of the design criteria must be supported by the following test data:

Strain gage testing of the complete aerial device
Analysis of deflection data taken while the aerial device was under test load The following standards for materials are to be used in the design of the aerial device:

Materials are to be certified by the mill that manufactured the material Material testing that is performed after the mill test will be for verification only and not with the intent of changing the classification
All welded structural components for the ladder will be traceable to their mill lots.

LADDER CONSTRUCTION
The ladder is comprised of four (
4 ) sections.

The ladder will have the capability to support a minimum of 750
lb at the tip in the unsupported
configuration, based upon
360
degree rotation, up to full extension and from -
10 degrees to +
77 degrees.

The ladder (handrails, baserails, trusses, K-braces and rungs) will be constructed of high strength 68 989
Bid #:

Page 389 of 519 ends

low alloy steel, minimum
100,000
pounds per square inch yield, with full traceability on all structural members.

Each section will be trussed diagonally, vertically and horizontally using welded steel tubing.

All ladder rungs are round and welded to each section utilizing "K" bracing for lateral and torsional rigidity.

The inside width dimensions of the ladder will be:

Base Section:

41.87 "
Lower Mid Section:

34.88 "
Upper Mid Section:

27.87 "
Fly Section:

21.63 "
The height of the handrails above the centerline of the rungs will be:

Base Section:

26.28 "
Lower Mid Section:

22.68 "
Upper Mid Section:

20.06 "
Fly Section:

17.32 "
The ladder will be designed to provide continuous egress for firefighters and civilians from an elevated position to the ground.

The egress section will be designed to maintain the rated load of the aerial device. It will be bolted on for easy replacement. There will be a lift eye welded on to each side of the egress.

VERTICAL HEIGHT
The ladder will extend to a minimum height of
107
' above the ground at full extension and
elevation. The measurement of height will be consistent with NFPA standards.

HORIZONTAL REACH
The rated horizontal reach will be
100
'. The measurement of horizontal reach will be consistent with NFPA standards.

TURNTABLE
The upper turntable assembly will connect the aerial ladder to the turntable bearing. The steel structure will have a mounting position for the aerial elevation cylinders, ladder connecting pins, and upper turntable operator's position.

The turntable will be coated with an non-skid, chemical resistant material in the walking areas.

The stepping surfaces will meet the skid-resistance requirements of the current NFPA standard.

The turntable handrails will be a minimum

42.00 " high and will not increase the overall travel
height of the vehicle. The handrails will be constructed from aluminum and have a slip resistant knurled surface. The turntable vertical handrail spacing will be designed with a

44.00 " wide x

27.00 " high opening to allow for equipment to pass through from the ground to the aerial ladder.

The opening will be located at the center, rear of the turntable. A chain will be provided across this opening.

ELEVATION SYSTEM
Dual

5.50 " diameter elevating cylinders will be mounted on the underside of the base section of the ladder, one (
1 ) on each side. One (
1 )

2.25 " diameter stainless steel pin will fasten each
cylinder to the ladder and one (
1 )

2.50 " diameter stainless steel pin will fasten each cylinder to the turntable. The pins will have
125,000
psi minimum yield strength and will be secured with

0.50 " Grade
8 bolts with castle nut and cotter pin. The bolts are to ensure that the pins do not walk out of the mounting brackets on the turntable and base section.

The elevating cylinders will be mounted utilizing maintenance-free spherical bearings on both ends of the cylinders. The aerial base pivot bearings will be maintenance-free type bearings with no external lubrication required.

The cylinders will function only to elevate the ladder and not as a structural member to stabilize the ladder side movement. The elevating cylinders will be provided with pilot-operated check valves on the barrel and rod side of the piston to prevent movement of the ladder in case of a loss of hydraulic pressure.

The operation envelope will be
10 degrees below horizontal to
77 degrees above
horizontal.

The elevation system will be designed following NFPA standards. The elevation hydraulic cylinders will incorporate cushions on the upper limit of travel.

The lift cylinders will be equipped with integral holding valves located in the cylinder to prevent the unit from descending should the charged lines be severed, at any point within the hydraulic system and to maintain the ladder in the bedded position during road travel.

The integral holding valves will NOT be located in the transfer tubes.

The elevation system will be controlled by the microprocessor. Linear transducers will measure the extension of the elevation cylinder. The microprocessor will provide the following features:

Collision avoidance of the elevation system to prevent accidental body damage Automatic deceleration when the aerial device is lowered into the cradle Automatic deceleration at the end of stroke, in maximum raise and lower positions Deceleration of the aerial device at the limits of travel.

EXTENSION/RETRACTION SYSTEM
A hydraulically powered, extension and retraction system will be provided through dual hydraulic cylinders and wire ropes. Each set will be capable of operating the ladder in the event of a failure, of the other. The extension cylinder rod will be chrome plated to provide smooth operation of the aerial device and reduce seal wear. The extension/retraction cylinders will be equipped, with integral holding valves, to prevent the unit from retracting should the charged line be severed, at any point within the hydraulic system. The integral holding valves will NOT be located in the transfer tubes.

Wire ropes and attaching systems used to extend and retract the fly sections will have a 5:1
safety factor based on the ultimate strength under all operating conditions. The factor of safety for the wire rope will remain above
2:1
during any extension or retraction stall.

The minimum ratio of the diameter of wire rope used to the diameter of the sheave used will be
1:12
. Wire ropes will be constructed of seven (
7 ) strands over an inner wire for
increased flexibility. The wire rope will be galvanized to reduce corrosion.

The extension/retraction system will be controlled by the microprocessor. Linear 69 989
Bid #:

Page 390 of 519 ends

transducers will measure the ladder extension. The microprocessor will provide the following features:

Automatic deceleration at the end of stroke, in maximum extend and retract positions All sheaves will require lubrication. They will have bronze bushings and grease zerks.

MANUAL OVERRIDE CONTROLS
Manual override controls will be provided for all aerial and stabilizer functions.

LADDER SLIDE MECHANISM
UHMW polyethylene wear pads will be used between the telescoping ladder sections, to provide greater bearing surface area for load transfer. Adjustable slide pads will be used to control side play between the ladder sections.

ROTATION SYSTEM
The aerial will be supplied with a powered rotation system as outlined in NFPA standards.

The hydraulic rotation motor will provide continuous rotation under all rated conditions and be supplied with a brake to prevent unintentional rotation. One ( 1 ) hydraulically
driven, planetary gear box with drive speed reducers will be used to provide infinite and minute rotation control throughout the entire rotational travel. One ( 1 ) spring applied,
hydraulically released disc type swing brake will be furnished to provide positive braking of the turntable assembly. Provisions will be made for emergency operation of the rotation system should complete loss of normal hydraulic power occur. The hydraulic system will be equipped with pressure relief valves which will limit the rotational torque to a nondestructive power. The gearbox will have a minimum continuous torque rating of 80,000
in. lbs. and a minimum intermittent rating of
160,000
in. lbs. The turntable bearing,
ring gear teeth, pinion gear, planetary gearbox,
and output shaft will be certified by the
manufacturer of the components for the application.

The rotation system will be controlled by the microprocessor. The microprocessor will provide the following features:

Collision avoidance to prevent accidental body damage
Prevent the aerial from being rotated into an unstable condition.

ROTATION INTERLOCK
The microprocessor will be used to prevent the rotation of the aerial device to the side in which the stabilizers have not been fully deployed (short-jacked). The microprocessor will allow full and unrestricted use of the aerial, in the
180
degree area, on the side(s) where
the stabilizers have been fully deployed. The system will also have a manual override to comply with the current edition of applicable NFPA standards.

LADDER CRADLE INTERLOCK SYSTEM
A ladder cradle interlock system will be provided through the microprocessor to prevent the lifting of the aerial device from the nested position until the operator places all the stabilizers in a load supporting configuration. A switch will be installed at the boom support to prevent operation of the stabilizers once the aerial has been elevated from the nested position.

AERIAL TORQUE BOX/PEDESTAL
The pedestal assembly will be a welded assembly made of high strength

0.25 " plate. The
vertical member will be a

0.375
" reinforced wall cylinder with a

28.00 " outside diameter
and will connect the rotation bearing mounting plate to the lower substructure.

The pedestal assembly will be bolted to the chassis frame with

0.88 " diameter Grade
8 bolts, and will be utilized to mount the outrigger jacks and reservoir for the aerial hydraulic system.

LOAD CAPACITIES
The following load capacities will be established with the stabilizers at full horizontal extension and placed in the down position to level the truck and to relieve the weight from the tires and axles. Capacities will be based upon full extension and 360
degree rotation.

A load chart, visible at the operator's station, will be provided. The load chart will show the recommended safe load at any condition of the aerial device's elevation and extension. 50 MPH WIND CONDITIONS/WATERWAY DRY
Degrees of
Elevation
-
10 to
9 10
to
19 20
to
29 30
to
39 40
to
49 50
to
59 60
to
69 70
to
77 Egress
750
750
750
750
750
750
750
750
Fly
-
-
-
-
-
250
500
750
Upper Mid
-
-
-
-
70 989
Bid #:

Page 391 of 519 ends

250
500
1000
1000
Lower Mid
-
-
-
-
500
750
1000
1000
Base
-
-
-
500
500
1000
1000
1000
50 MPH WIND CONDITIONS/WATERWAY CHARGED
Degrees of
Elevation
-
10 to
9 10
to
19 20
to
29 30
to
39 40
to
49 50
to
59 60
to
69 70
to
77 Egress
500
500
500
500
500
500
500
500
Fly
-
-
-
-
-
250
500
500
Upper Mid
-
-
-
-
250
500
750
1000
Lower Mid
-
-
-
250
500
750
1000
1000
Base
-
-
250
500
750
1000
1000
1000
Reduced loads at the tip can be redistributed in
250
lb increments to the fly, mid, or base
sections as needed.

The tip capacity will be reduced to zero when flowing water with the nozzle above the waterway centerline.

BOOM SUPPORT
A heavy-duty boom support will be provided for support of the ladder in the travel position. On the base section of the ladder, a stainless steel scuffplate will be provided where the ladder comes into contact with the boom support. 71 989
Bid #:

Page 392 of 519 ends

0762413
Light, Boom Support, Amdor AY-LB-
12HW012, 12" LED

AERIAL BOOM SUPPORT LIGHT
There will be one (
1 ) Amdor®, Model AY-LB-
12 HW
012
,
190
lumen,
12 " long, white LED strip light
mounted on the boom support cradle. This light will be activated when the aerial master switch is activated.
0755127
Tie Down, Rope, Per Pair, 9000lb
Rating, Trailer Gooseneck, Tiller

ROPE TIE DOWN AT GOOSENECK
There will be
two (
2 ) pairs
of rope tie downs provided
each side of the tiller gooseneck in the
forward and rearward locations
. Equal quantities will be provided on each side. The tie downs will be rated for a straight line pull of
9000
lb and will be
nickel plated
.
0663833
Boom Support, Raised, Tiller

SPECIAL HEIGHT BOOM SUPPORT
A special height boom support will be provided to raise the aerial device to clear the compartment
on top of the body
.
0680821
Boom Panel, Pair

AERIAL BOOM PANEL
There will be one boom panel provided on each side of the aerial ladder base section. The boom panel will be painted
Red
90 . Customer requests that NO bolts show on the exterior of the panel per previous job
#27235
.

The boom panels will be designed so no mounting bolts are in the face of the panel. This will keep the lettering surface free of holes.
0526885
Indicator, Extension, Inside and
Outside Handrails, Every 10'

EXTENSION INDICATOR
Extension markings and corresponding numerical indicators will be provided along each inside and outside top rail of the base section of the aerial every 10 '. They will indicate various positions
of extension up to full. Markings and indicators will be clearly visible to the console operator. To aid in visibility during hours of darkness, the markings and numerical indicators will be red

reflective material.
0723719
Steps, Folding, Four, Aerial Device,
Trident

FOLDING STEPS
One (
1 ) set of folding steps will be provided at the tip of the ladder. An additional set of folding steps will be provided at the base of the fly section. The steps will be black powder coated finish

with
a luminescent tread coating, that is rechargeable from any light source and can hold a charge for up to
24 hours,
on the stepping surface. Each step will have
no integrated light
.
0688232
Rung Covers, Aerial Device

AERIAL DEVICE RUNG COVERS
Each rung will be covered with a secure, heavy-duty, fiberglass pultrusion that incorporates an aggressive, no-slip coating.

The rung covers will be glued to each rung and will be easily replaceable should the rung cover become damaged.

The center portion of each rung cover will be black and the outside

2.00 " edge at each side will
be
photoluminescent to assist in providing a light source for each rung during low light conditions .

Under no circumstances will the rung covers be fastened to the rungs using screws or rivets.

The rung covers will have a
10 -year, limited warranty.
0674963
Scabbard, Temporary Vent Saw
Storage, No Depth Gauge, Aerial
Ladder

TEMPORARY SCABBARD AT END OF AERIAL
There will be a total of
two (
2 )
vent saw scabbard(s) provided. The scabbard(s) will be mounted on
each side of the aerial egress
. The scabbard(s) will be DA finished.
0678539
Brackets Only, Roof/Wall Ladder,
Aerial Fly Section

LADDER STORAGE MOUNTING BRACKETS
There will be brackets that are
painted to match the aerial device
provided near the end of the fly
section of the aerial for mounting a roof ladder.

The mounting brackets will accommodate a
14 ' Duo-Safety
875
-A,

16.00 " wide
roof/wall ladder as
determined by the type of aerial device and the available space. 0786841
Brackets Only, Roof/Fresno Ladder,
Base Section, Inboard of Boom Panel

LADDER STORAGE MOUNTING BRACKETS
Mounting will be provided on
each side of the aerial device
for storage of
two (
2 )
roof ladder(s).

The bracket(s) will be located inboard of the boom panel at the base section. The bracket(s) will hold the boom panel as close to the base section as possible and include straps to secure the ladder.

The mounting brackets will accommodate a
14 ' Duo-Safety
775
-DR and
8 ' Duo-Safety
875
-DR

roof ladder as determined by the type of aerial device and the available space. 0601972
Lights, Turntable Walkway, P25, LED

LIGHTS FOR TURNTABLE WALKWAY
There will be white LED lights provided at the aerial turntable. The lights will be located to illuminate the entire walking surface of the turntable including the area around the turntable console. These lights will be activated by the aerial master switch. 72 989
Bid #:

Page 393 of 519 ends

0601949
Light, Turntable Console, TecNiq T-
10, LED Strip Light

TURNTABLE CONSOLE LIGHTING
There will be one (
1 ) TecNiq, Model T
10 , white LED light strip mounted in the turntable console cover to illuminate the controls located on both the upper and lower portion of the turntable control station. These lights will be activated by the aerial master switch. 0771409
Hoist Rings, S/S, Forward Area of
Turntable, Ascendant, LSL

HOIST RINGS
There will be two (
2 ) stainless steel hoist rings located on the turntable.

One (
1 ) to be mounted on each side of the vertical surface of the lift cylinder ear at the front of the turntable (aerial side).

The rating of each hoist ring will be a maximum of
1000
lb in all directions. There will be a label
indicating this rating provided next to the hoist rings. 0771410
SP
Eyes,(2) Rear Of T/T,6.00" Off
Center,Rope Tie Off,Use w/Rope Tie
Bar/LyfePulley

EYELETS FOR ROPE TIE OFF POINTS
Two (
2 ) eyelets will be mounted near the edge at the rear edge of the turntable to be used as a rope tie off point. Eyelets will be provided that are approximately

6.00 " off the center on each
side. They will be spaced as not to interfere with handrail mounting.

The rating on each of these eyelets will be no more than 750
lbs. An adjacent label to each eyelet
will indicate this.
0682074
Box, Ladder Belt Storage, Turntable

LADDER BELT STORAGE BOX AT TURNTABLE
A storage box with a hinged cover will be provided at the turntable. The box and cover will be constructed of aluminum treadplate. The box will be large enough to contain four (
4 )
ladder belt
(s).
0619248
SP
Cover, Raised, Control Station

CONTROL STATION COVER
The cover provided at the turntable control station will be made taller than standard to allow the intercom controls, speaker,
120
volt tip light switch (if applicable), and/or waterway shutoff valve control (if applicable) to be installed under the console cover. 0814632
Control Stations, ASL Tiller, MUX,
Color Display, CL714

INFORMATION CENTER
There will be an information center provided at the aerial turntable control station. The information center will operate in temperatures from -
40 to
158
degrees Fahrenheit. The information center
will employ a Linux operating system and a

7.00 " (diagonal measurement) LCD display. The LCD
will have a
1000
nits rated, color display. The LCD will be sunlight readable. The LCD display will be encased in an ABS, grey plastic housing with a Pierce decal. There will be five ( 5 ), weather-
resistant user interface switches provided. The LCD display can be changed to an available foreign language.

OPERATION
The information center will be designed for easy operation in everyday use. There will be a page button to cycle from one screen to the next screen in a rotating fashion. A video button will allow an NTSC signal into the information center to be displayed on the LCD. If any button is pressed while viewing a video feed, the information center will return to the vehicle information screens.

There will be a menu button to provide access to maintenance, setup, and diagnostic screens. All other button labels will be specific to the information being viewed.

GENERAL SCREEN DESIGN
Where possible, background colors will be used to provide vehicle information At A
Glance
. If the
information provided on a screen is within acceptable limits, a green background color will be used. If the information provided on a screen is not within acceptable limits, an amber background color will indicate a caution condition and a red background color will indicate a warning condition.

Every screen in the information center will include the aerial tip temperature, the time ( 12 - or
24 -
hour mode) and a text Alert Center. The time will be synchronized between all Command Zone color displays located on the vehicle. The Alert Center will display text messages for audible alarms. The text messages will identify any items causing the audible alarm to sound. If more than one (
1 ) audible alarm is activated, the text message for each alarm will cycle every second until the problems have been resolved. The background for the Alert Center will change to indicate the severity of the warning message. Amber will indicate a caution condition and red will indicate a warning condition. If a warning and a caution condition occur simultaneously, the red background color will be shown for all Alert Center messages.

A label will be provided for each button. The label will indicate the function for each active button for each screen. If the button is not utilized on specific screens, it will have a button label with no text.

Symbols will accurately depict the aerial device type the information pertains to such as rear mount ladder, rear mount platform, mid-mount ladder or mid-mount platform.

PAGE SCREENS
The Information center will include the following pages:

The Aerial Main and Load Chart page will indicate the following information:

Rungs Aligned and Rungs Not Aligned will be indicated with text and respective green or red colored ladder symbols.

Ladder Elevation will be indicated via a fire apparatus vehicle with ladder symbol with the degree of elevation indicated between the vehicle and ladder.

Water Flow (if applicable) will be indicated via a water nozzle symbol and text indicating flow / time.

Breathing Air Levels will be indicated via an air bottle symbol and text indicating the percent (%) of air remaining. A green bar graphs shown inside the bottle will indicate oxygen levels above 20%
. A red bar graph will indicate oxygen levels at or below 20%
. When oxygen levels are at or
below
10%
the red bar graph will flash.

The Aerial Load Chart will indicate the load limit on each section of the ladder based on actual ladder position and water flow (if applicable).

At A Glance
color features will be utilized on this screen. Caution type conditions will be indicated 73 989
Bid #:

Page 394 of 519 ends

via a yellow background. Warning type conditions will be indicated via a red background.

Conditions operating within acceptable limits will be indicated via a green background.

The Aerial Reach and Hydraulic Systems page will indicate the following information:

Aerial Hydraulic Oil Temperature will be indicated with symbol and text. At a glance features will be utilized.

Aerial Hydraulic Oil Pressure will be indicated with a symbol and text. At a glance features will be utilized.

The following calculations will be indicated on a representative vehicle symbol:

Aerial Device Extension length.

Aerial Device Height indicating the height of the aerial device tip from the ground.

Aerial Device Reach indicating the horizontal distance the aerial reaches from the turntable.

Aerial Device Angle indicating the angle from the vehicle which the device is at.

At A Glance
color features will be utilized on this screen. Caution type conditions will be indicated via a yellow background. Warning type conditions will be indicated via a red background.

Conditions operating within acceptable limits will be indicated via a green background.

The Level Vehicle page will indicate the following information:

The grade of the vehicle will be indicated via a fire apparatus vehicle symbol with the degree of grade shown in text format. The symbol will tilt dependent on the vehicle grade.

The slope of the vehicle will be indicated via a fire apparatus vehicle symbol with the degree of slope shown in text format. The symbol will tilt dependent on the vehicle slope.

Outriggers status will be indicated via a colored symbol for each outrigger present. Each outrigger status will be defined as one of the following:

Outrigger stowed indicated with a silver pan located close to the vehicle Outrigger fully extended indicated with a fully deployed green outrigger Outrigger short-jacked indicated by a yellow outrigger partially deployed Outrigger not set indicated by a red outrigger that is not set on the ground A text box located on the vehicle symbol will be utilized to identify the overall status of the outrigger leveling system. The following status will be indicated in the text box:

Deployed status will indicate all outriggers are properly set on the ground at full extension Shortjacked status will indicate one or more outriggers are set on the ground but not fully extended.

Not Set status will indicate one or more outriggers is not properly set on the ground.

Stowed status will indicate all outriggers are stowed for vehicle travel.

A bedding assist alert will indicate that the aerial device is being aligned by the Command Zone system as the operator lowers the aerial device into the cradle with the joystick.

At A Glance
color features will be utilized on this screen. Caution type conditions will be indicated via a yellow background. Warning type conditions will be indicated via a red background.

Conditions operating within acceptable limits will be indicated via a green background.

MENU SCREENS
The following screens will be available through the Menu button:

The View System Information screen will display aerial device hours, aerial PTO hours, ladder aligned for stowing, aerial rotation angle, total water flow (if applicable), and aerial waterway valve status (if applicable).

The Set Display Brightness screen will allow brightness increase and decrease and include a default setting button.

The Configure Video Mode screen will allow setting of video contrast, video color and video tint.

The Set Startup screen allows setting of the screen that will be active at vehicle power-up.

The Set Date and Time screen has a
12 - or
24 -hour format, and allows setting of the time and
date.

The View Active Alarms screen shows a list of all active alarms including the date and time of each alarm occurrence and shows all alarms that are silenced.

The System Diagnostics screen allows the user to view system status for each module and it's respective inputs and outputs. Viewable data will include the module type and ID number; the module version; and module diagnostics information including input or output number, the circuit number connected to that input or output, the circuit name (item connected to the circuit), status of the input or output, and other module diagnostic information.

Aerial calibrations screen indicates items that may be calibrated by the user and instructions to follow for proper calibration of the aerial device.

Button functions and button labels may change with each screen.

STABILIZER CONTROL STATION
There will be an easily accessible control station located on the trailer gooseneck, one ( 1 ) each
side of the apparatus. The following controls and indicator lights will be clearly identified and conveniently located for ease of operation and viewing at each control station.

Driver Side/Passenger Side In/Out control switches
Driver Side/Passenger Side Up/Down control switches
Driver Side/Passenger Side Fully Extended indicator lights Driver Side/Passenger Side Firm On Ground indicator lights Stabilizer Emergency Power control switch
Trailer Level Assist control toggle switch
Global Safety Interlock Override red guarded switch
Aerial system Emergency Stop switch
Aerial system Emergency Stop Activated indicator light

TURNTABLE CONTROL STATION
There will be one (
1 ) device control station located on the right side of the turntable so the operator may easily observe the ladder tip while operating the controls. All elevation, extension and rotation controls will operate from this location. The controls will permit the operator to regulate the speed of the aerial functions, within the safe limits, as determined by the manufacturer and NFPA standards. Each control will be equipped, with a positive lock to hold the control in a neutral position, preventing accidental activation. In addition to the neutral lock, a console cover will be provided at the turntable control station.

The following items will also be provided at the turntable control station, clearly identified and lighted for nighttime operation and conveniently located for ease of operation and viewing:

Intercom controls
Tip tracking light switch
Emergency stop switch
Emergency power unit switch
Operator's load chart
Two (
2 ) position switch for selecting aerial operational speed 74 989
Bid #:

Page 395 of 519 ends

HIGH IDLE
The high idle will be controlled by the microprocessor. The microprocessor will automatically adjust the engine rpm to compensate for the amount of load placed upon the system. The system will include a safety device that allows activation of the high idle, only when the parking brake is set and the transmission is placed in neutral.
0743299
Remote Tip Controls, ASL/105' MUX

REMOTE AERIAL CONTROL
A remote control will be provided whereby all ladder movements can be controlled at the ladder tip, in addition to the control console.

The three (
3 ) ladder functions (extension, rotation, elevation) will be controlled individually by means of spring loaded, return to center
12 -volt proportional controls.

A momentary switch at the turntable control station will enable the controls at the ladder tip.

The turntable control console ladder controls will override the ladder tip controls.

The remote control aerial speed will be set in accordance with the current edition of applicable NFPA standards.
75 989
Bid #:

Page 396 of 519 ends

0789602
Stabilizers, ASL Tractor Drawn Steel
Aerial, Split Pan, 17' Spread

STABILIZERS
The vehicle will come equipped with a stabilization system consisting of two ( 2 ) hydraulically
operated out and down style stabilizers. This system will meet or exceed all requirements of the NFPA specifications related to stabilization and setup on sloped surfaces.

The stabilizer/leveling jacks will have a maximum spread of 17 ' measured from the centerline of
the jack footpads when the beams are fully extended. The beams will be

6.81 " wide x

8.88 " high
with

0.75 " thick top and bottom plates and

0.50 " thick sides of
100,000
-PSI minimum yield
strength steel. The cylinders will have pilot-operated check valves with thermal relief designed to ensure that the beams will not drift out of the stowed position during travel. Wear pads will guide the stabilizers.

The horizontal extension cylinders will be totally enclosed within the beams and will incorporate telescoping hydraulic tubing to supply the jack cylinder hydraulic power. Stabilizer hydraulic hoses will remain stationary during operation of the stabilizers to prevent hose wear and potential failure. The cylinders will be equipped with decelerators to reduce the speed of extension and retraction when the beams are near the fully retracted and extended positions. The stabilizer extension hydraulic cylinders will have the following dimensions:

2.25 " bore,

1.38 " rod, and

57.25 "
stroke.

The vertical jack cylinders will be capable of

12.00 " ground penetration. The cylinders will be
supplied with pilot operated check valves on each jack cylinder to hold the cylinder in the stowed or working position, should a charged line be severed at any point in the hydraulic system. For safety, the integral holding valves will be located in the cylinder base end, NOT in the transfer tube. Vertical jack cylinder rods will be fully enclosed by a telescoping inner box to protect the cylinder rods from damage. The stabilizer jack hydraulic cylinders will have the following dimensions:

4.25 " bore,

3.00 " rod, and

28.88 " stroke.

Each stabilizer jack will have a pan that will be of the split-pan design and will be a maximum

12.50 " wide so as to allow the extension of the stabilizer between parked cars or other obstacles.

This pan will serve as a protective guard and a mounting surface for warning lights. The top, forward, and rear edges will be flanged back
90 degrees for added strength.

STABILIZER PADS
The stabilizer footpad will be

12.00 " in diameter. The footpad will be attached to the jack cylinder rod by means of a machined ball at the end of the jack cylinder rod which mates to a socket machined into the footpad. The footpad will have the ability to pivot 20 degrees from horizontal in
any direction to allow setup on uneven terrain.

AUXILIARY STABILIZER PADS
An auxiliary ground pad will be supplied for each stabilizer to provide additional load distribution on soft surfaces. The pads will be

24.00 " square and made from
lightweight composite material
.

The ground pressure will not exceed
75 lb per square inch when the ground pads are used and the apparatus is fully loaded and the aerial device is carrying its rated capacity in any position.

There will be one (
1 ) pad located on each side of the apparatus, behind the stabilizers.

STABILIZER CONTROLS
An electrically controlled hydraulic valve will power stabilizer movement. The valve can also be manually controlled in the event of electrical malfunction. Hydraulic power override controls will be incorporated into the valve. The manual override mechanism will be completely sealed within the valve assembly to prevent any possibility of corrosion.

The stabilizer controls will be located on the trailer gooseneck, one ( 1 ) each side of the
apparatus, to provide the operator with a full view of each stabilizer being positioned. Each stabilizer control panel will include the following:

Driver Side/Passenger Side In/Out control toggle switches Driver Side/Passenger Side Up/Down control toggle switches Driver Side/Passenger Side Fully Extended indicator lights Driver Side/Passenger Side Firm On Ground indicator lights Stabilizer Emergency Power control toggle switch
Trailer Level Assist control toggle switch
Global Safety Interlock Override red guarded toggle switch Aerial system Emergency Stop mushroom switch
Aerial system Emergency Stop Activated indicator light
As a safety device, an electrically actuated diverter valve will be provided. The hydraulic power will be diverted to the aerial ladder controls automatically the instant all stabilizer jacks are firmly planted on the ground. Once the aerial ladder is raised from the bedded position, the stabilizer hydraulic power is cut off so the stabilizers will not accidentally be moved while the aerial is being operated.

To aid in leveling the unit, two (
2 ) bubble type angle indicators will be located near the stabilizer controls. One (
1 ) indicator will show the angle of the truck from the front to rear and the other will show the side to side angle of the truck. The indicators will be color coded green to show when the truck has been properly leveled allowing the aerial device to be operated at full capacity.

A stabilizer deployment audible warning alarm will be provided at each side of the body, activated by the stabilizer movement.

A "Stabilizers Not Stowed" indicator light will be provided in the cab within view of the driver. It will illuminate automatically whenever the stabilizers are not fully stowed to prevent damage to the vehicle if it is moved. The stabilizer system will also be wired to the "Do Not Move Truck" indicator light. This light will flash whenever the apparatus parking brake is not engaged and the stabilizers are not fully stowed.
0728961
Stabilizer Pan Material

STABILIZER PAN MATERIAL
The aerial stabilizer pans will be
smooth aluminum, painted to match the lower body color
.
0530819
Not Required, Aerial Stabilizer Pins

STABILIZER PINS
The stabilizer jacks will not have holes for the stabilizer pins. 76 989
Bid #:

Page 397 of 519 ends

0779621
Doors, Stabilizer Control Box,
Valve/Electrical Distribution Box,
Tiller

STABILIZER CONTROL BOX DOORS
There will be
aluminum treadplate
doors hinged
on the bottom
with a
flush lift and turn latch

provided over each stabilizer control box.

VALVE/POWER DISTRIBUTION BOX ACCESS DOOR
There will be
aluminum treadplate
doors with a
flush lift and turn latch
provided over the valve
and power distribution box doors. These doors will be bottom hinged. 0629913
Lights, Stabilizer Pad Locator, Wln
Micro MPB*, Rec Stb S Pn, Sw Ft

STABILIZER GROUND ILLUMINATION LIGHT
There will be
two (
2 )
Whelen Micro Pioneer, Model MPB*,
12 volt DC LED spot light(s) provided.

The light(s) will be recessed in the stationary stabilizer pan..

The light(s) will indicate where the stabilizer pad will be set down.

The
painted parts of this light assembly to be black
.

The light(s) will be recessed into the stabilizer side cover plate on the aerial platform body and trimmed with a polished stainless steel housing/garnish ring.

The light(s) will be activated per the following selections:
a switch at the driver's side switch panel
no additional switch location
when the aerial master switch is activated
no additional switch location
0540495
Pads, Stabilizer, Modified to Slide On

STABILIZER PADS, MODIFIED
The
two (
2 )
auxiliary stabilizer pads will be modified so they can be installed on the bottom of the stabilizer. The auxiliary stabilizer pad holders on the truck will also be modified. 0747060
Hydraulic System, Special Reservoir,
ASL Tiller

HYDRAULIC SYSTEM
All hose assemblies will be assembled and crimped by the hose manufacturers certified technician.

All manufacturing employees responsible for the installation of hydraulic components will be properly trained. Training will include: proper handling, installation, torque requirements, cleanliness and quality control procedures for hydraulic components.

Hoses used in the aerial hydraulic system will be of a premium quality hose with a high abrasion resistant cover. All pressure hoses will have a working pressure of 4000
psi and a burst pressure
rating of
16,000
psi.

All hydraulic fittings and tubing will be plated to minimize corrosion.

The fitting will use an O-ring seal where possible to minimize hydraulic leaks.

An interlock will be provided that prevents activation of the hydraulic pump until the transmission is placed in neutral and the parking brake is set as outlined in the current NFPA standard.

The system will meet the performance requirement of the current NFPA standard, which requires adequate cooling less than

2.5 hours of operations.

All hydraulic components that are non-sealing whose failure could result in the movement of the aerial will comply with current NFPA standards and have burst strength of 4:1
.

Dynamic sealing components whose failure could cause aerial movement will have a margin of 2:1
on maximum operating pressure per the current NFPA standard.

All hydraulic hoses, tubes, and connections will have a minimum burst strength of 4:1
per the
current NFPA standard.

A chassis mounted positive displacement piston pump for consistent pressure and rapid responses will supply hydraulic power for all aerial operations. The positive displacement pump will provide
3,150
psi. The hydraulic pump will be solely dedicated to aerial operations.

The hydraulic oil will be a premium Multi-Vis product having a leading edge additive package, provide oxidation stability, be extremely shear stable and maximum anti-wear properties. All oil delivered to the manufacturing site will have a minimum ISO cleanliness level of 18/15/13
.

Each aerial will be evaluated as to the region and climate where it will be used to determine the optimum viscosity and proper oil grade. Oil viscosity will be based on an optimum range of 80 to
1000
SUS during normal aerial use. Before shipment of the unit, an oil sample will be taken and analyzed to confirm the oil is within the allowable ISO grade tolerance.

The aerial hydraulic system will have a minimum oil cleanliness level of ISO 18/15/13
based on
the ISO
4406:1999
cleanliness standard. Each customer will receive a certificate of actual cleanliness test results and an explanation of the rating system.

Each aerial will include an oil sample port, identified with a yellow dust cap and a label, for subsequent customer testing.

Ball valves will be provided in the hydraulic suction lines to permit component servicing without draining the oil reservoir.

The aerial will incorporate the use of trombone steel tubes inside the stabilizer beams to eliminate hydraulic hose wear and leaks.

Hydraulic power to the ladder will be transferred from the pedestal by a hydraulic swivel.

The system hydraulic pressure will be displayed on the turntable display.

The hydraulic system will be additionally protected from excessive pressure by a secondary pressure relief valve set at
3,150
psi. In the event the main hydraulic pump compensator
malfunctions, the secondary relief will prevent system damage.

HYDRAULIC CYLINDERS
All cylinders used on the aerial device will be produced by a manufacturer that specializes in the manufacture of hydraulic cylinders.

Each cylinder will include integral safety holding cartridges.

Each cylinder will be designed to a minimum safety factor of 4:1
to failure.

All safety holding cartridges will be installed at the cylinder manufacturer, in a controlled clean environment to avoid possible contamination and or failure.

POWER TAKEOFF/HYDRAULIC PUMP
The apparatus will be equipped with a power takeoff driven by the chassis transmission and actuated by an electric shift, located inside the cab. The power takeoff which drives the hydraulic pump will meet all the requirements for the aerial unit operations.

Am amber indicator light will be installed on the cab instrument panel to notify the operator that the power takeoff is engaged.

An interlock will be provided that allows operation of aerial power only after the chassis spring 77 989
Bid #:

Page 398 of 519 ends

brake has been set and the chassis transmission has either been placed in the neutral position or drive position after the driveline has been disengaged from the rear axle.

The hydraulic system will be supplied by a variable displacement load and pressure compensating piston pump. The pump will meet the demands of all three simultaneous aerial functions. The pump will provide proper flow for single aerial function with the engine at idle speed. A switch will be provided on the control console to increase the engine speed for multiple function operation.

EMERGENCY PUMP
The hydraulic system will be designed with an auxiliary power unit meeting the guidelines of the current NFPA
1901
standard.

The aerial will be equipped with an emergency hydraulic pump, electrically driven from the truck batteries. The pump will be capable of running for
30 minutes for limited aerial functions to stow
the unit in case of a main pump or truck system failure. A momentary switch will be located at the stabilizer and aerial control locations to activate the emergency pump.

AERIAL CONTROL VALVE
The aerial hydraulic control valve will be designed with special spool flows, limiting the oil flow for the designed function speed. The valve will be electrically controlled and be located in the control console with the handles oriented downward for manual operation. The activation handles will be spaced a minimum of

3.50 " for ease of operation. The valve spools will be designed to bleed off downstream pressure, in the neutral position and allow proper sealing of any cylinder holding cartridge.

OIL RESERVOIR
The oil reservoir will have a minimum capacity of
40 gallons. The oil fill location will be easily
accessible and be labeled "Hydraulic Oil Only" and also indicate the grade of oil that is installed in the reservoir. The fill cap will have a
40 micron filter to provide protection from contamination. A drain hose will be included and will terminate with a quarter turn ball valve.

Two suction ports will be provided, one for the main hydraulic pump and one for the emergency pump. The main suction will be slightly elevated off the bottom of the reservoir and include a 100

mesh suction strainer. The emergency suction port will be closer to the bottom of the reservoir to provide some reserve oil for emergency operation.

A six (
6 ) disc type magnetic drain will also be provided to collect any ferrous contaminants.

A combination sight glass and thermometer will be mounted to the reservoir in an easily viewable location.

The hydraulic oil reservoir will be labeled per the current edition of NFPA standard.

RETURN FILTER
The low pressure oil return filter will be remote mounted and designed to prevent oil loss during filter change. A
50 psi bypass will be included to protect the element and hydraulic system during lower than normal operating temperatures. The system will incorporate the following filter to provide dependable service:
return filter: beta
200
at
6 micron
0786880
Swivels, D-Series w/Encoder, ASL-
Tandem/Tiller, MUX (32 Collector
Rings)

HYDRAULIC SWIVEL
The aerial ladder will be equipped with a three (
3 ) port, high pressure hydraulic swivel which will
connect the hydraulic lines from the hydraulic pump and reservoir through the rotation point to the aerial control bank. The hydraulic swivel will allow for 360
degree continuous rotation of the
aerial.

ELECTRIC SWIVEL
The ladder will be equipped with an electric swivel to allow 360
degrees rotation of the aerial
while connecting all electrical circuits through the rotation point. A minimum of 32 collector rings
will be provided that are capable of supplying
30 amp continuous service. All collector rings will
be enclosed and protected with desiccant plugs against condensation and corrosion. No oil or silicone will be used.
12 -BIT ABSOLUTE ENCODER
The aerial ladder will be equipped with a
12 -Bit Absolute Encoder which provides
4096
counts
per shaft turn for position and direction reference.

The
12 -Bit Absolute Encoder will provide a unique binary word to reference each position and direction for all
360
degrees of rotation.

If the power is interrupted for any reason, the
12 -Bit Absolute Encoder will allow power to be
returned to the system without having to re-zero the settings.

The
12 -Bit Absolute Encoder will be an integral part of a micro-processor based control system. 78 989
Bid #:

Page 399 of 519 ends

0815131
Electrical System, ASL Tiller, MUX,
10/8 Cable

ELECTRICAL SYSTEM
The standard
8 conductor cable to the tip contains
10 AWG conductors.

The aerial device will utilize a microprocessor-based control system. The system will consist of the following components:

Control System Modules
Each of the control system modules will be configured as follows:

Sealed to a NEMA
4 rating
Operating range from -
40 degrees F to
185
degrees F (-
40 degrees C to
85 degrees C)
Communicate using J
1939
data link
Two (
2 ) diagnostic LED light
One (
1 ) green light that illuminates when module has power (B+) and ground One (
1 ) red light that flashes to indicate the module is capable of communicating via the data link Ground matrix identification system
The following control system modules will be used:

Control Module
Main controller for the system
USB connection allows for computer diagnostics
Power Module
Built-in fault sensing
Eight (
8 ) digital outputs
Pulse width modulating (PWM) capable
10 A continuous per output
Circuit protection based on actual current draw (not affected by heat) Constant Current Module
Built-in fault sensing
Three (
3 ) analog inputs
Eight (
8 ) digital outputs
Pulse width modulating (PWM) capable
4 A continuous per output
Circuit protection based on actual current draw (not affected by heat) Closed Loop System
Input Module
16 software selectable (digital or analog) inputs
Output Module
16 digital outputs
Input/Output Module
Eight (
8 ) software selectable (digital or analog) inputs
Eight (
8 ) digital outputs
0804781
Aerial Scene Lts Separated into
Aerial Tip Category and Aerial
Tracking Category
0803462
Lights, Tip, Wln MP** LED, 2lts

TIP LIGHT
There will be two (
2 ) Whelen® Model MP**,
5,695
lumens
12 volt DC LED lights installed at the
tip of the aerial device.

One (
1 ) will be located on the left side with
left side tip light to include spot optics
.

One (
1 ) will be located on the right side with
right side tip light to include spot optics
.

The
light(s) to be installed on adjustable bail bracket(s)
.

The
painted parts of this light assembly to be black
The lights will be controlled with the tracking lights. 0802753
Lights, Tracking, Wln MP** LED, 2lts

TRACKING LIGHTS
There will be two (
2 ) Whelen® MP**,
5,695
lumens
12 volt DC LED lights installed on the base
section of the aerial device below the hand rails per the following:

One (
1 ) will be located on the left side with
left side tracking light to include spot optics
.

One (
1 ) will be located on the right side with
right side tracking light to include spot optics
.

The
light(s) to be installed on adjustable bail bracket(s)
.

The
painted parts of this light assembly to be black
.

The tracking lights will be controlled by a switch located at the platform/tip and turntable
.
0653677
Lighting, Rung, LED, TecNiq, 4
Section, Base, Lower/Upper Mid, Fly

LIGHTING ON AERIAL LADDER
There will be TecNiq, Model D
02 LED rung lighting provided on both sides of the aerial ladder base, lower and upper mid, and fly sections. The lighting will be located adjacent to the ladder rungs along the lower rail of the ladder sections and will run the length of the ladder section.

The color of the sections will be:

The
base section of the ladder to be red
.

The
lower mid section of the ladder to be red
.

The
upper mid section of the ladder to be red
.

The
fly section of the ladder, excluding the egress, to be red .

The LED rung lighting will be activated when
a switch at the turntable operator's panel is
activated through the aerial master and a switch at the turntable operator's panel is activated through the master battery switch
.

The lights may be load managed when the parking brake is applied. 0540725
Lights, Stabilizer Warn (1) Set, Wln
M6* LED, Rear Colored Lens

STABILIZER WARNING LIGHTS
There will be two (
2 ) LED flashing warning lights with chrome flanges installed on the stabilizer cover panels, one (
1 ) each side.

The rear stabilizer pan lights will be
red
LED with a lens the same color as the LEDs.

These warning lights will be activated by the same switch as the side warning lights. 79 989
Bid #:

Page 400 of 519 ends

0068703
Lights, Grote Supernova LED,
Stabilizer Beam, (1) Set

STABILIZER BEAM WARNING LIGHTS
Two (
2 )

4.00 " diameter red LED flashing lights will be mounted on each stabilizer, one ( 1 ) facing
forward and one (
1 ) facing rearward. The lights will be Grote Supernova 40 series LED lights. The
lights will be recessed in the horizontal beam of the stabilizer. These warning lights will be activated with the aerial master switch.
0601980
Lights, Stabilizer Scene, (1) set,
Truck-Lite 40227C, Incandescent

STABILIZER SCENE LIGHTS
There will be one (
1 ) Truck-Lite, Model
40227
C

4.00 " incandescent, scene light installed under
each stabilizer beam to illuminate the surrounding area. A total of two ( 2 ) lights will be installed.

These lights will be activated by the aerial master switch. 0783034
DC Power To Aerial Tip, 13.92 Amps
@ 12 Volt DC, ASL
DC POWER CABLE to TIP
There will be a cable installed in the aerial device to provide

13.92 amps @
12 volts DC to the tip
of the aerial device.
0724821
SP
Intercom, 2-Way Fire Research
ICA910 Hands Free (Special
Location, Con)
2 -WAY AERIAL COMMUNICATION SYSTEM
There will be a Fire Research, Model ICA
910
, two-way intercom system provided. The control
module with LED volume display and push-button volume control and speaker will be located in the turntable operator console, provided there is room.

A hands free module will be located at the aerial tip or platform and constantly transmit to the other module unless the control module push-to-talk button is pressed.

Each intercom unit will be weatherproof.
0540895
Not Required, Breathing Air to Tip,
Aerial Ladder
0024742
Not Required, Mask, Breathing Air To
Tip
0066919
Not Required, Raised Pedestal, Tiller
0604457
Lifting Eye Assembly, Rope Rescue
Attachment, ASL, LSL

LIFTING EYE ASSEMBLY - ROPE RESCUE ATTACHMENT
A lifting eye assembly will be provided that is designed to evenly distribute load at the tip of the aerial. The lift eye assembly is retained by two (
2 ) locking pins, one (
1 ) at each end outboard side
of the egress. Leveling is maintained by the lifting eye assembly rotating within the egress mounting. The lifting eye assembly rating will match the capacity rating of the aerial device. 0709614
SP
Rope Tie Bar At Base Section,forLyfe
Pulley,Compt Storage,Ascend,105'
HDL,Tiller

ROPE TIE BAR AT BASE SECTION, RESCUE LIFTING SYSTEM
A removable bracket shall be supplied at the rear of the base section, attached between the left hand and right hand rear hand rails. The bracket shall provide Lyfe Pulley rope tie off and/or guide points spaced

5.75 " apart, centered between the rear hand rails. The bracket shall be designed to be easily removable and not interfere with a fully retracted ladder assembly when attached to the base section. The bracket shall be stored in a compartment. 0786677
Rope Tie Bar At Base Section,
Painted Box, Rescue Lifting System,
w/ Winch

ROPE TIE BAR AT BASE SECTION, RESCUE LIFTING SYSTEM WITH WINCH A removable bracket will be supplied at the rear of the base section, attached between the left hand and right hand rear hand rails. The bracket will provide Lyfe Pulley rope tie off and/or guide points centered between the rear hand rails. The bracket will be designed to be easily removable and not interfere with a fully retracted ladder assembly when attached to the base section. A storage box for the bracket will be provided on the outside rear of the base section. The storage box and bracket will be painted to match the aerial device.

There will be a Harken Model

40.2 ST winch with

10.00 " (
254
mm) handle provided and mounted
directly to the top of the removable bracket and centered between the rope tie off eyes. The winch will be rated for a
500
lb maximum load that will allow straight or horizontal side pulls only.

A label will be provided near the winch to indicate the 500
lb maximum load.
0808215
LyfePulley, Rescue System

RESCUE LIFTING SYSTEM
A rescue lifting attachment will be provided. The lifting attachment will mount to the aerial
egress and will consist of a pair of nylatron pulleys mounted to a stainless steel shaft. The pulleys will be adjustable from side to side and will have a total lifting capacity of 750
lb,
regardless of whether one (
1 ) or both pulleys are being utilized.
0530828
Turntable Access, Chains

AERIAL TURNTABLE CHAIN
A chain will be installed at the aerial turntable.
80 989
Bid #:

Page 401 of 519 ends

0790402
Waterway, High Flow, ASL-Tiller

WATER SYSTEM
A waterway system will be provided consisting of the following components and features:

A

5.00 " pipe will be connected to the water supply on one end and to a

5.00 " internal diameter
water swivel at the rotation point of the turntable. The water swivel will permit 360
degree
continuous rotation of the aerial device.

The

5.00 " waterway swivel is to be routed through the rotation point up to the heel pin swivel. The heel pin swivel will allow the water to flow to the ladder pipe while elevating the aerial ladder from -
10 degrees to
77 degrees. The heel pivot pin is not integral with the waterway swivel at any point. The design of the waterway will allow complete servicing of the waterway swivel without disturbing the heel pivot pin.

The integral telescopic water system will consist of a

4.50 " diameter tube in the base section, a

4.00 " diameter tube in the inner mid-section, a

3.50 " diameter tube in the outer mid-section, and a

3.00 " diameter tube in the fly section. The telescopic waterway will be constructed of anodized aluminum pipe.

The aerial will be capable of discharging up to
1000
gpm at
100
psi parallel to the ladder and
90 degrees to each side of center while maintaining the rated tip load.

The aerial will be capable of discharging between
1001
and up to
1500
gallons per minute at
100

psi parallel to the ladder and
40 degrees to each side of center while maintaining the rated tip load.

The master stream will be capable of flow up to
30 degrees above horizontal.

An adjustable pressure relief valve will be furnished to protect the aerial waterway from a pressure surge.

Two (
2 )

1.50 " drain valves will be located at the lowest points of the waterway system and will be routed to drain through the center of the
5 th wheel.

WATERWAY SEALS
The waterway seals will be of type-B PolyPak design, composed of nitroxile seal and a nitrile wiper, which together offer maximum stability and extrusion resistance on the waterway. The seal will be capable of withstanding pressures up to
2000
psi, temperatures in excess of
250
degrees
Fahrenheit and have resistance to all foam generating solutions. The seals will be internally lubricated.

The waterway seals will have automatic centering guides constructed of synthetic thermalpolymer. The guides will provide positive centering of the extendible sections within each other and the base section to insure longer service life and smoother operation. 0632855
Monitor, Akron 3480 StreamMaster II
Electric w/Extended Vertical Travel

AERIAL MONITOR
An Akron Model
3480
monitor with stow and deploy will be provided at the tip with a Akron
1250

gpm Model
1578
. This monitor will allow for an additional
30 degrees of travel above horizontal at
the aerial tip.

The monitor's functions will be controlled electrically from two ( 2 ) separate locations. One (
1 )
control will be located at the control console and the other at the ladder tip.

There will be a courtesy light at the tip of the aerial to illuminate the controls.

If the aerial has a quick-lock waterway, a limit switch will be provided to disable the extended vertical travel when the monitor is locked to the lower ladder section. 0010758
Flow Meter, Waterway, PAL, 110'
Ascendant, MUX

AERIAL WATERWAY FLOW METER
Waterway flow, including total water flowed, will be monitored by the microprocessor. An LCD display will be located at the turntable control station. 0512000
Inlet, Aerial Waterway, 4.00"
Plumbing with 5.00" Inlet, Tiller

AERIAL WATERWAY INLET
The aerial waterway will be plumbed from the fifth wheel area to the waterway swivel with

4.00 "
pipe. A

5.00 " inlet will be located on each side of the apparatus complete with a chrome plated cap. The individual "line" pressure gauges for the inlets will be manufactured by Class 1 . They will
be a minimum of

3.50 " in diameter and will have white faces with black lettering. Gauges will be compound type with a vacuum/pressure range of

30.00 "-
0-600#
.

The individual pressure gauge will be installed as close to the inlet as practical. 0673128
Quick-Lock Waterway Locking
System, 100' HDL, 105' HDL, ASL

WATERWAY LOCKING SYSTEM
The aerial ladder waterway monitor will be capable of being positioned at either the fly section or at the next lower section of the ladder.

The monitor location will be changeable by the use of a single handle, located at the side of the ladder.

The handle, attached to a cam bracket, will simply be moved forward to lock the monitor at the fly section and back to lock it to the previous section.

There will be no pins to remove and reinstall.

The monitor will be operational at all times, regardless of its position, without connecting or disconnecting electrical lines.
0768548
Label, Pinnable Waterway Lock,
Ascendant

QUICK-LOCK WATER WAY LOCK LABELING
The Quick-Lock waterway locking mechanism will be labeled "LOWER FLY" "RELEASE" "UPPER FLY". Three (
3 ) labels will be installed on the side of the pinnable waterway release lever mounting bracket.
0013164
Elbow, Aerial Inlet, 5" FNST x 5"
Storz w/Cap

ADAPTER, STORZ INLET
There will be
two (
2 )

5.00 " FNST x

5.00 " Storz
30 degree elbow(s) with blind cap provided
on
each side of the aerial waterway inlets
.
81 989
Bid #:

Page 402 of 519 ends

0047897
Tools, Aerial

TOOLS
The following tools will be provided for retorquing of all specified bolts as recommended by the manufacturer:

Torque Wrench
All Required Extensions, Sockets and Adapters
4 -to-
1 Multiplier
0668583
Manuals and Training, 4 Consecutive
Days, Ascendant Ladder, PAL,
English

MANUALS
Two (
2 ) operator maintenance manuals and two (
2 ) wiring diagrams pertaining to the aerial
device will be provided with the apparatus at time of pick-up. Manuals will be in the English language.

INITIAL INSTRUCTION
On initial delivery of the fire apparatus, the contractor will supply a qualified representative to demonstrate the apparatus and provide initial instruction to the fire department regarding the operation, care, and maintenance of the apparatus for a period of four ( 4 ) consecutive days.
0645891
Chart, Lubrication Points, Number
and Location

LUBRICATION CHART
two (
2 )
copie(s) of a lubrication chart will be provided with the manuals. The chart will indicate the total number of lubrication points and their locations. 0832200
Cab, Tiller, Sliding Doors, 2025

TILLER CAB
A permanently mounted tiller cab will be located on top of the tiller trailer, to the rear of the aerial ladder. The maximum overall height of the tiller cab will not exceed 134.00
". The tiller cab will be
totally enclosed.

The cab windshield will be automotive approved tinted safety glass and will provide a minimum of 1,513
square inches of clear viewing area.

Each side window, directly rearward of the windshield, will be more than 536
square inches. The
side windows, combined with the windshield, will provide a minimum of 2,585
square inches of
unobstructed viewing area. In order to provide maximum visibility for the tillerman, there will be no corner posts at the forward corners of the windshield.

Two (
2 ) slide back doors, one each side of cab will be provided. Doors will be mounted on top and bottom slides which will be lockable in either open or closed position. A minimum door opening of

21.50 " will be provided when entering and exiting the tiller cab. The tiller cab doors will be equipped with drop-down windows. The windows will be

18.00 " wide x

31.00 " high.

The rear wall of the tiller cab will have a vertically-split sliding window. The window will be

33.50 "
wide x

27.75 " high.

The tiller cab floor will be constructed of aluminum treadplate.

A two (
2 ) speed electric windshield wiper with washer will be provided for the front windshield.

The windshield washer reservoir will have a capacity of two ( 2 ) quarts and will be located forward
of the tiller cab.

An adjustable, telescopic steering column will be provided.

The diagnostic plug for the trailer ABS system will be provided in the driver side tiller access stepwell, behind the fuel fill door.

The following controls/alarms will be provided inside the tiller cab:

Buzzer signaling system with push button in tiller cab steering wheel as well as a labeled push button in the tractor cab, within reach of the driver.

Jackknife alarm
The following will be provided on the steering column support pedestal:

Two (
2 ) heater/defroster outlets
Heater/defroster control switch
The following controls/gauges will be located in the upper control panel:

Tiller wheel position indicator LCD color display gauge (L-C-R) Two (
2 ) LED amber turn signals
Windshield wiper/washer control switch
0726222
Sun Visor, Smoked Lexan, Tiller Cab
A smoked Lexan
™
sun visor will be provided in the tiller cab above the windshield. There will be a black plastic thumb latch
provided to help secure the sun visor in the stowed position. 0636262
Light, Dome, Weldon Dual LED 1lt

TILLER CAB DOME LIGHT
There will be one (
1 ) P
1006
, dual LED dome light with
grey
bezel installed in the tiller cab.

The color of the LED will be
red and white
.

The white LED will be controlled by
the door switches and the lens switch
.

The color LED will be controlled by
the lens switch
.
0724595
Heater/Defroster, Tiller Cab, Electric,
Dual 12V, 3 Spd, No Thermo, Med
Climate

TILLER CAB HEATER/DEFROSTER
There will be two (
2 ) DC Thermal, Model SA
12-4000
, combination heater/defroster provided in
the tiller cab. The system will be
12 volt and will be powered through the tractor ignition circuit.

Each heater will have a max of
5,000
BTU.

Each heater/defroster will have a
3 -speed motor and a high/low heat switch located in the tiller cab within reach of the tillerman.

There will be a minimum of two (
2 ) defrost outlets in the cab for maximum defrost performance.

The system will be
12 volt and will be powered through the tractor ignition circuit.

The heater/defrost system will have an airflow of
220
cfm.
82 989
Bid #:

Page 403 of 519 ends

0734216
SP
Air Conditioner, Tiller Cab, Painted,
2019

TILLER CAB AIR CONDITIONING
Air conditioning will be provided for the tiller cab.

The unit will be manufactured by Danhard Inc.

The air conditioner will have cooling capacity of
13,500
BTU.

The in tiller cab venting will route via louvers included on the B-pillar of the tiller cab.

The unit will be
120
volt AC and will be run off of the onboard generator. The full load amperage draw will be

12.00 amps in the cooling mode.

The evaporator will be located ahead of the tiller cab on the top deck of the tiller trailer. The air conditioning unit will not increase the overall height of the tiller cab.

The evaporator cover will be painted to match the job color. 0746465
SP
Seat, Tiller, Pierce PS6, Premium, Air
Ride Hi-Back, w/Arm Rests

TILLER CAB SEAT
A seat will be provided in the tiller cab. The seat will be a cam action type, with air suspension.

For increased convenience, the seat will include a manual control to adjust the horizontal position (

6.00 " travel). The manual horizontal control will be a towel-bar style located below the forward part of the seat cushion. The seat will have a reclining back adjustable from 20 degrees back to
0 degrees forward. The seat back will be a high back style with manual lumbar adjustment lever, and will include minimum

7.50 " deep side bolster pads for maximum support. For optimal comfort, the seat will be provided with

17.00 " deep dual density foam cushions designed with EVC (elastomeric vibration control). An arm rest will be provided on each side of the seat. To ensure safe operation, the seat will be equipped with seat belt sensors in the seat cushion and belt receptacle that will activate an alarm indicating a seat is occupied but not buckled.

The seat will be furnished with a
3 -point, shoulder type seat belt. The seat belt will be furnished with dual automatic retractors that will provide ease of operation in the normal seating position. 0831942
SP
Steps,Tiller Cab Access,
w/Reinforced Channels, Moved Rear,
Ea Side,60" Rear Ht

TILLER CAB STEPS
For access to the tiller cab, two (
2 ) sets of steps will be furnished at the rear of the apparatus, one set each side. The steps will be moved rearward and be in alignment with the tiller cab door.

The bottom three (
3 ) access steps will be full width, approximately

21.00 " wide and the top two
(
2 ) steps will be full width, approximately

18.50 " wide. The steps will be securely reinforced and constructed of aluminum treadplate. There will be a reinforcing channel provided on the underside of each step. Handrails will be provided on each side of the step assemblies for maximum safety; a vertical handrail will be on the forward side and a candy cane style will be provided on the rearward side. A vertical handrail will also be provided on the tiller cab. The steps will be illuminated for nighttime operation.
0888725
SP
Ind Warn, Cab Seatbelt Warn,
Jackknife Warn Wln VTX609B, FB
UT-09-515-S, Dual

JACKKNIFE ALARM
There will be two (
2 ) Floyd Bell, Model UT-
09-515
-S, staccato tone audible alarms and two (
2 )
Whelen, Model VTX
609
B, blue flashing LED lights activated when the jackknife position approaches the maximum allowable angle which is
65 degrees. There will also be two (
2 ) Floyd
Bell, Model UO-
09-515
-S, whoop tone audible alarms activated when the jackknife position approaches collision which is
80 degrees.

One (
1 ) of each alarm and light will be installed in the tractor cab within view of the tractor driver.

One (
1 ) of each alarm and light will be installed in the tiller cab within view of the tiller driver.

At
80 degrees jackknife position both alarms will sound, the staccato alarm will not deactivate at 80 degrees jackknife position.

TILLER WARNING INDICATOR
A warning indicator in the tractor cab will be activated if the parking brake is released and the tiller driver is not seated and buckled in the tiller cab. 0012207
Mirror, 6" Round Convex, Tiller Cab
(PR)
CONVEX MIRRORS (tiller cab)
A

6.00 " diameter round convex mirror with adjustable arm will be installed on each side of tiller cab.
0600100
Bracket, Wedge, 30 Degree, HVAC
Controls

HVAC CONTROL BRACKET
There will be one (
1 )
30 degree wedge bracket for mounting the A/C/heater/defroster controls onto. This will allow the Tillerman to view the control screens from where he is seated. 0766006
Air Conditioning Condenser Cover,
Treadplate, Knockouts

AIR CONDITIONER CONDENSER COVER
There will be a treadplate cover provided over the tiller cab air conditioner condenser. Knockouts will be provided to allow for proper air flow and circulation. 0634358
Steering Shaft, Raised for Raised
Rear Body/Tiller Cab

TILLER CAB STEERING
The steering shaft provided for the tiller cab will be designed to accommodate a raised rear body.

The rear body will be raised

6.00 "
.
0099824
Footswitch, Engine Start in Tiller Cab,
W/Master Override Switch In Tractor
Cab

ENGINE START IN TILLER CAB
A foot switch will be provided in the tiller cab on the passenger side to allow the truck to be started. If the switch is not pressed the truck will not start.

There will be a master override switch located in the cab which will allow the truck to be started in the unlikely event that the switch at the tiller cab would fail.

The switch in the cab will be a covered momentary switch. 83 989
Bid #:

Page 404 of 519 ends

0051052
Window Defrost Fans (2)

WINDOW DEFROST FANS
Two (
2 ) window defrost fans will be mounted
one each side of the tiller steering column
.
0615412
Deflectors, Tiller Cab Air Vents,
Angled Towards Windshield

VENT DEFLECTORS
There will be painted aluminum deflectors provided around the tiller cab air vents to help direct the air towards the windshield to help maintain clear visibility through the tiller cab windshield. 0763551
SP
Tinted Glass, Medium Gray, 40-50%,
Tiller Cab Door Windows

WINDOW TINT
The tiller cab side door sliding windows will be tinted medium gray, a 40-50%
tint range.
0732242
SP
Tinted Glass, Medium Gray, 40%-
50%, Tiller Cab Rear Wall Window

WINDOW TINT
The tiller cab rear wall sliding window will be tinted medium gray, a 40-50%
tint range.
0821772
SP
UV Protection,3M Ceramic IR Series
Solar Film,Till Cab
Windshield,Drs,Rear Wind

WINDOW UV PROTECTION
The tiller cab windshield, rear wall sliding window and each door window will have 3 M
™,
Ceramic
IR series, UV protection film applied.
0768851
SP
Air Conditioner and Heater Controls,
Angled Panel, Special Loc, Tiller Cab

TILLER CAB HVAC CONTROLS LOCATION
The controls for the tiller cab air conditioner and heater will be installed on an angled panel located
AC controls RS Dash and Heater Controls LS Dash
.
0535631
SP
Light, Indicator and Buzzer, Cab and
Body Doors Open, Tiller Cab

TILLER INDICATOR LIGHT
Two (
2 ) amber indicator lights and buzzers will be provided in the tiller cab to indicate when any driver side or passenger side cab and body doors are open. The lights will be wired into the "door open warning circuit" the same as in the cab. The system will not activate until the parking brake has been released. The indicator lights will be visible to the tillerman in an overhead switch panel, the lights will be labeled "DS DOOR OPEN" and "PS DOOR OPEN". 0521828
SP
Door Lock, Keyed, Tiller Cab Door, to
Match Cab, Exterior Only

TILLER CAB DOOR LOCKS
The door on the tiller cab will be furnished with lockable exterior handles. The tiller door and all cab and crew cab doors will be keyed alike.
0601213
SP
Vent Louvers, (2) Aluminum, IPOS,
Tiller Cab

VENT LOUVERS
The tiller cab vent louvers will be aluminum.
0626771
Trailer, 3.00" Extended Gooseneck,
Single Axle Only, Tiller

TILLER TRAILER
The gooseneck area of the tiller trailer will be constructed of 100,000
psi minimum yield strength
steel.

The gooseneck area will have a section modulus of
289.00
cu. in. and a resistance to bending
moment of
28,900,000
inch pounds.

The gooseneck area will be

46.00 " wide x

13.50 " deep.

The tiller trailer frame will be box type construction to effectively resist trailer twist.

The side rails will have a

13.38 " tall web over the front and mid sections of the trailer, with a continuous smooth taper to a

10.75 " over the tiller axle.

The frame rails will be constructed of
80,000
psi minimum yield strength heat treated .
38 " thick
steel, with

3.50 " wide flanges and covered by top and bottom plates to form a ridged box structure. Cover plates will be
50,000
psi minimum yield strength steel.

The tiller trailer frame will have a section modulus of 257.70
cu. in., and a resisting bending
moment (rbm) of
12,880,000
inch pounds over the critical regions of the frame assembly, with a section modulus of

18.96 cu. in. with an rbm of
2,085,803
inch pounds over the rear axle.

The overall length of the tiller trailer will be
471.00
". The gooseneck area of the trailer will be
extended

3.00 ".
0090681
Walkway, Turntable to Body, Tiller

WALKWAY, TURNTABLE TO BODY
A walkway will be provided from the aerial turntable to the tiller body. 84 989
Bid #:

Page 405 of 519 ends

0052481
Axle, Tiller Trailer, Oshkosh TAK-4,
Non Drive, 22,800#

TILLER TRAILER NON DRIVE AXLE
The tiller trailer axle will be of the independent suspension design with a ground rating of 22,800

lb.

Upper and lower control arms will be used on each side of the axle. Upper control arm castings will be made of
100,000
-psi yield strength
8630
steel and the lower control arm casting will be
made of
55,000
-psi yield ductile iron.

The center cross members and side plates will be constructed out of 80,000
-psi yield strength
steel.

Each control arm will be mounted to the center section using elastomer bushings. These rubber bushings will rotate on low friction plain bearings and be lubricated for life. Each bushing will also have a flange end to absorb longitudinal impact loads, reducing noise and vibrations.

The upper control arm will be shorter than the lower arm so that wheel end geometry provides positive camber when deflected below rated load and negative chamber above rated load.

Camber at load will be zero degrees for optimum tire life.

The kingpin bearing will be of low friction design and be sealed for life.

Toe links that are adjustable for alignment of the wheel to the center of the trailer will be provided.

The wheel ends must have little to no bump steer when the chassis encounters a hole or obstacle.

The steering linkage will provide proper steering angles for the inside and outside wheel, based on the vehicle wheelbase.

The turning angle will be up to
24 degrees.

TILLER TRAILER NON DRIVE AXLE WARRANTY
The non drive axle system will have a
three (
3 ) year parts
and labor warranty.
0032125
Steering, Sheppard M110 w/tilt, TAK-
4, Tiller Trailer

TILLER TRAILER STEERING
Dual Sheppard M
110
steering gears, with integral heavy-duty power steering, will be provided.

The steering wheel will be

18.00 " in diameter, and capable of tilting and telescoping.

A lock-out pin will be provided on the tiller cab steering column. 0652502
Brakes, Meritor, EX225, 17", Disc
Plus, TAK-4, Tiller
BRAKES
The tiller trailer brake calipers will be Meritor® DiscPlus ™
EX
225
air disc type. The brake rotors
will be

17.00 " ventilated.
0052483
Suspension, Tiller, 22,800#

SUSPENSION
Independent suspension will be provided with a minimum ground rating of 22,800
lb.

The independent suspension system will be designed to provide maximum ride comfort. The design will allow the vehicle to travel at highway speeds over improved road surfaces, and at moderate speeds over rough terrain with minimal transfer of road shock and vibration to the vehicle's crew compartment.

Each wheel will have torsion bar type spring. In addition, each wheel end will also have energy absorbing jounce bumpers to prevent bottoming of the suspension.

The suspension design will be such that there is at least

10.00 " of total wheel travel and a
minimum of

3.75 " before suspension bottoms.

The torsion bar type spring and anchor lock system will allow for simple lean adjustments without the use of shims. Adjustment for a lean will be accomplished within 15 minutes. Anchor
adjustment design is such that it allows

4.00 " of ride height adjustment per side.

The independent suspension will have been put through a durability test that simulated a minimum of
140,000
miles of inner city driving.
0088777
Tires, Michelin, XZY 3 (wb),
425/65R22.50 20 ply (tiller)
TIRES
Tiller trailer tires will be Michelin
425/65
R

22.50 radials,
20 ply all-position XZY
3 wide base tread,
rated for
22,800
lb maximum axle load and
65 mph maximum speed.
0037030
Wheels, Alum. Alcoa, 22.50" x 12.25"
(385/425), Tiller

WHEELS, TILLER
The tires will be mounted on Alcoa®

22.50 " x

12.25 " polished aluminum disc type wheels with a
ten (
10 )-stud

11.25 " bolt circle.
0037050
Oil Seals, Tiller Axle

OIL SEALS
Oil seals with viewing window will be provided on the tiller axle. 0007150
Bag of Nuts and Bolts

LOOSE EQUIPMENT
The following equipment will be furnished with the completed unit:

One (
1 ) bag
of chrome, stainless steel, or cadmium plated screws, nuts, bolts and washers, as used in the construction of the unit.
85 989
Bid #:

Page 406 of 519 ends

0816498
NFPA Required Loose Equipment,
Aerial, NFPA/ULC 2024, Provided by
Fire Dept

NFPA LOOSE EQUIPMENT
NFPA Required Loose Equipment Provided by Fire Department The following loose equipment as outlined in NFPA
1900
,
2024
edition, table

8.1 and CAN/ULC
S
515:2024
edition, section

5.2 will be provided by the fire department:

One (
1 ) traffic vest for each seating position, each vest to comply with ANSI/ISEA 107
,
American
National Standard for High-Visibility Safety Apparel and Accessories , and have a five-point
breakaway feature that includes two (
2 ) at the shoulders, two (
2 ) at the sides, and one (
1 ) at the
front.

Five (
5 ) fluorescent orange traffic cones not less than

28.00 " (
711
mm) in height, each equipped
with a

6.00 " (
152
mm) retro-reflective white band no more than

4.00 " (
152
mm) from the top of
the cone, and an additional

4.00 " (
102
mm) retro-reflective white band

2.00 " (
51 mm) below the

6.00 " (
152
mm) band.

Five (
5 ) illuminated warning devices such as highway flares, unless the five ( 5 ) fluorescent
orange traffic cones have illuminating capabilities.

Four (
4 ) ladder belts meeting the requirements of NFPA
2500
.

NFPA Loose Equipment That Should be Considered
The following loose equipment as outlined in NFPA
1900
,
2024
edition, appendix table A.

8.4 (a)
and CAN/ULC S
515:2024
edition, section

5.2 should be considered:

Two (
2 )
3 ft -
4 ft plaster hooks with D handles mounted in brackets fastened to the apparatus Two (
2 ) crowbars
Two (
2 ) claw tools
Two (
2 )
12 lb (
5 kg) sledgehammers
Four (
4 ) SCBA apparatus
Four (
4 ) SCBA spare cylinders
One (
1 ) first aid kit
Six (
6 ) salvage covers, each a minimum size of
12 ft ×
18 ft (

3.6 m ×

5.5 m)
Four (
4 ) combination spanner wrenches
Two (
2 ) scoop shovels
One (
1 ) pair of bolt cutters,

24.00 " (

0.6 m) minimum
One (
1 )
150
ft (
45 m) light-use life safety rope meeting the requirements of NFPA 2500
One (
1 )
150
ft (
45 m) general-use life safety rope meeting the requirements of NFPA 2500
One (
1 )
150
ft (
45 m) utility ropes having a breaking strength of at least 5000
lb (
2300
kg)
One (
1 ) box of tools to include the following:
one (
1 ) hacksaw with three (
3 ) blades
one (
1 ) keyhole saw
one (
1 )
12 " (.
3 m) pipe wrench
one (
1 )
24 " (.
6 m) pipe wrench
one (
1 ) ballpeen hammer
one (
1 ) pair of tin snips
one (
1 ) pair of pliers
one (
1 ) pair of lineman's pliers
assorted types and sizes of screwdrivers
assorted adjustable wrenches
assorted combination wrenches
One (
1 ) automatic external defibrillator (AED)
0816941
Soft Suction Hose, Provided by Fire
Department, NFPA/ULC 2024

SOFT SUCTION HOSE PROVIDED BY FIRE DEPARTMENT
Hose is not on the apparatus as manufactured. The fire department will provide suction or supply hose.
0816939
Extinguisher, Dry Chemical, NFPA
2024, Provided by Fire Department

DRY CHEMICAL EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0816937
Extinguisher, 2.5 Gal. Pressurized
Water, NFPA/ULC 2024, Provided by
Fire Dept

WATER EXTINGUISHER PROVIDED BY FIRE DEPARTMENT
The extinguisher is not on the apparatus as manufactured. The fire department will provide and mount the extinguisher.
0007482
Not Required, Crowbars

0007484
Not Required, Claw Tools

0816998
Axe, Flathead, Provided by Fire
Department

FLATHEAD AXE PROVIDED BY FIRE DEPARTMENT
The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe.
0817000
Axe, Pickhead, Provided by Fire
Department

PICKHEAD AXE PROVIDED BY FIRE DEPARTMENT
The axe is not on the apparatus as manufactured. The fire department will provide and mount the axe.
0007494
Not Required, Sledgehammers

86 989
Bid #:

Page 407 of 519 ends

0741569
Paint Process / Environmental
Requirements, Appleton

PAINT PROCESS
The exterior custom cab and body painting procedure will consist of a seven ( 7 ) step finishing
process as follows:

Manual Surface Preparation
- All exposed metal surfaces on the custom cab and body will be thoroughly cleaned and prepared for painting. Imperfections on the exterior surfaces will be removed and sanded to a smooth finish. Exterior seams will be sealed before painting. Exterior surfaces that will not be painted include; chrome plating, polished stainless steel, anodized aluminum and bright aluminum treadplate.

Chemical Cleaning and Pretreatment
- All surfaces will be chemically cleaned to remove dirt, oil, grease, and metal oxides to ensure the subsequent coatings bond well. The aluminum surfaces will be properly cleaned and treated using a high pressure, high temperature 4 step Acid Etch
process. The steel and stainless surfaces will be properly cleaned and treated using a high temperature
3 step process specifically designed for steel or stainless. The chemical treatment converts the metal surface to a passive condition to help prevent corrosion.

Surfacer Primer
- The Surfacer Primer will be applied to a chemically treated metal surface to provide a strong corrosion protective basecoat. A minimum thickness of 2 mils of Surfacer Primer
is applied to surfaces that require a Critical aesthetic finish. The Surfacer Primer is a two- component high solids urethane that has excellent sanding properties and an extra smooth finish when sanded.

Finish Sanding
- The Surfacer Primer will be sanded with a fine grit abrasive to achieve an ultra- smooth finish. This sanding process is critical to produce the smooth mirror like finish in the topcoat.

Sealer Primer
- The Sealer Primer is applied prior to the Basecoat in all areas that have not been previously primed with the Surfacer Primer. The Sealer Primer is a two-component high solids urethane that goes on smooth and provides excellent gloss hold out when topcoated.

Base
coat Paint
- Two coats of a high performance, two component high solids polyurethane basecoat will be applied. The Basecoat will be applied to a thickness that will achieve the proper color match. The Basecoat will be used in conjunction with a urethane clear coat to provide protection from the environment.

Clear Coat
- Two (
2 ) coats of Clear Coat will be applied over the Basecoat color. The Clear Coat is a two-component high solids urethane that provides superior gloss and durability to the exterior surfaces. Lap style and roll-up doors will be Clear Coated to match the body. Paint warranty for the roll-up doors will be provided by the roll-up door manufacturer.

After the cab and body are painted, the color will be verified to make sure that it matches the color standard. Electronic color measuring equipment will be used to compare the color sample to the color standard entered into the computer. Color specifications will be used to determine the color match. A Delta E reading will be used to determine a good color match within each family color.

All removable items such as brackets, compartment doors, door hinges, and trim will be removed and painted separately if required, to ensure paint behind all mounted items. Body assemblies that cannot be finish painted after assembly will be finish painted before assembly.

The paint finish quality levels for critical areas of the apparatus (cab front and sides, body sides and doors, and boom lettering panels) are to meet or exceed Cadillac/General Motors GMW
15777
global paint requirements. Orange peel levels are to meet or exceed the #6
A.C.T.
standard in critical areas. The manufacture's written paint standards will be available upon request.

Environmental Impact
Contractor will meet or exceed all current state regulations concerning paint operations. Pollution control will include measures to protect the atmosphere, water and soil. Controls will include the following conditions:

Topcoats and primers will be chrome and lead free.

Metal treatment chemicals will be chrome free. The wastewater generated in the metal treatment process will be treated on-site to remove any other heavy metals.

Particulate emission collection from sanding operations will have a

99.99 percent efficiency
factor.

Particulate emissions from painting operations will be collected by a dry filter or water wash process. If the dry filter is used, it will have an efficiency rating of 98 percent. Water wash
systems will be

99.97 percent efficient.

Water from water wash booths will be reused. Solids will be removed on a continual basis to keep the water clean.

Paint wastes are disposed of in an environmentally safe manner.

Empty metal paint containers will be recycled to recover the metal.

Solvents used in clean-up operations will be recycled on-site or sent off-site for distillation and returned for reuse.

Additionally, the finished apparatus will not be manufactured with or contain products that have ozone depleting substances. Contractor will, upon demand, present evidence that the manufacturing facility meets the above conditions and that it is in compliance with his state EPA rules and regulations.
0709846
Paint, Two-Tone Color,
Velocity/Impel

CAB TWO-TONE PAINT
The cab will be painted two-tone, with the upper section painted Pierce
994
(Match
38759
)
and
the lower section painted
Pierce
1019
Red (Match
38759
)
. There will be
a standard two-tone cab
paint break provided
.

There will be
a high cab shield provided
.
0709845
Paint, Single Color, Body

BODY PAINT
The body will be
painted to match the lower section of the cab
.
0509327
Paint, Two Tone, Tiller Cab
PAINT
The cab will be two-tone, with the upper section painted Pierce
994
and the lower section of the
cab painted
Pierce Red
1019
.

The paint break will be located
Standard Paint Break
.
87 989
Bid #:

Page 408 of 519 ends

0646897
Paint Chassis Frame Assy, E-Coat,
Standard

PAINT CHASSIS FRAME ASSEMBLY
The chassis frame assembly will be finished with
primer and gloss paint to match the lower job
color
before the installation of the cab and body, and before installation of the engine and transmission assembly, air brake lines, electrical wire harnesses, etc.

Components treated with epoxy E-coat protection prior to paint:

Two (
2 ) C-channel frame rails
Components that are included with the chassis frame assembly that will be painted not e-coated (unless otherwise stated in a secondary option) are:

Cross members
Axles
Suspensions
Steering gear
Battery boxes
Bumper extension weldment
Frame extensions
Body mounting angles
Rear Body support substructure (front and rear)
Pump house substructure
Steel fuel tank
Castings
Individual piece parts used in chassis and body assembly The E-coat process will meet the technical properties shown. 0693797
No Paint Required, Aluminum Front
Wheels

0693792
No Paint Required, Aluminum Rear
Wheels

0809564
No Paint Required, Aluminum Tiller
Wheels
0733739
Paint, Axle Hubs

AXLE HUB PAINT
All axle hubs will be painted
to match lower job color
.
0887826
Coating, UL-LX, Accessory Compt
Door

ACCESSORY COMPARTMENT DOOR
There will be
one (
1 )
accessory compartment door(s) sprayed with
black
UL-LX®
polyurethane/polyurea material. The locations will be
B
2 - Interior side of Compartment door B
2 .

The lining will be properly installed by an authorized UL-LX dealer. 0823974
SP
Coating, Safe-Stride,Top Surf Tiller
Trailer,A/C Cond/Hose Line,No
Lower Catwalk

TRAILER HORIZONTAL COATING
Portions of the trailer will be coated with
grey
Safe-Stride® anti-slip coating to help reduce glare
for the tillerman.

Surfaces to be coated include:

Top, horizontal surfaces of the front, center and rear body module All drip rails
Tiller cab air conditioning condenser and hose lines will also be covered (if applicable) 0581434
Transit Coating, Carwell, Corrosion
Protection, Including Underside

TRANSIT COATING
All non-painted metal surfaces on the exterior of the vehicle will be sprayed with a corrosion protective coating provided by Carwell. The coating can be removed with soap and water.

The coating is made of a linseed oil base and is biodegradable.

The underside non-painted metal surfaces will also be coated with a corrosion protective coating. 0760810
Coating, Safe-Stride, Tiller A/C, Top
of Cover in Front of Tiller Cab

TILLER CAB A/C COVER COATING
There will be
grey
Safe-Stride® anti-slip coating provided on the top of the tiller A/C evaporator cover directly in front of the tiller cab.
0007230
Compartment, Painted, Spatter Gray

COMPARTMENT INTERIOR PAINT
The interior of all compartments will be painted with a gray spatter finish for ease of cleaning and to make it easier to touch up scratches and nicks.
88 989
Bid #:

Page 409 of 519 ends

0790913
Aerial Ladder Paint, Incl Gooseneck,
Stabilizers, Tiller

AERIAL DEVICE PAINT COLOR
The aerial device paint procedure will consist of a seven ( 7 ) step finishing process as follows:
1 .

Manual Surface Preparation
- All exposed metal surfaces on the aerial device structural components above the rotation point will be thoroughly cleaned and mechanically shot-blasted to remove metal impurities and prepare the aerial for painting. 2 .

Zinc Rich Primer
- Zinc rich primer will be applied to the trailer including the gooseneck and stabilizer housings, stabilizer beams and jacks, and upper 5 th wheel components.
3 .

Primer/Surfacer Coats
- A two (
2 ) component epoxy primer/surfacer will be applied to the mechanically shot-blasted metal surfaces to provide a strong corrosion protective base coat and to smooth out the surface. All seams will be caulked with a two ( 2 ) component epoxy caulk before
painting.
4 .

Hand Sanding
- The primer/surfacer coat of the outer surfaces of the hand rails and base rails will be lightly sanded to a smooth finish.
5 .

Primer Coat
- A two (
2 ) component epoxy primer coat will be applied over the sanded primer. 6 .

Topcoat Paint
- Urethane base coat will be applied to opacity for correct color matching. 7 .

Clear Coat
- Two (
2 ) coats of an automotive grade two (
2 ) component urethane will be applied.

Surfaces that will not be painted include all chrome plated, polished stainless steel, anodized aluminum and bright aluminum treadplate.

All buy out components, such as monitor, nozzle, gauges, etc. will be supplied as received from the vendor.

Removable items such as brackets will be removed and painted separately to ensure paint coverage behind all mounted items.

The aerial device components will be painted as follows using the aforementioned seven ( 7 ) step
finishing process:

Aerial device ladder sections and extension cylinders:
charcoal metallic
479
Aerial turntable:
charcoal metallic
479
Aerial control console:
charcoal metallic
479
Aerial lift cylinders:
charcoal metallic
479
Aerial rotation motor (if applicable):
charcoal metallic
479
Aerial trailer including the gooseneck and stabilizer housings, 5 th wheel components below the
rotation point, body support structure, tiller axle and suspension:
red
90 Aerial stabilizers:
red
90 Aerial egress:
#90
red
(will be contrasting color to the aerial device ladder sections) Aerial boom support:
red
90 0544124
Reflective Band, 1"-4"-1"

REFLECTIVE STRIPES
Three (
3 ) reflective stripes will be provided across the front of the vehicle and along the sides of the body. The reflective band will consist of a

1.00 "
black
stripe at the top with a

1.00 " gap then a

4.00 "
black
stripe with a

1.00 " gap and a

1.00 "
black
stripe on the bottom.
0077356
Reflective, Cab Face, Below the S/S
Trim Band

REFLECTIVE STRIPE ON CAB FACE
The reflective band provided on the cab face will be located below the stainless steel trim band and above the front bumper.
0820104
Stripe, Chevron, Rear, Reflective,
NFPA/ULC 2024, Tiller

REAR CHEVRON STRIPING
There will be alternating chevron striping located on the rear-facing vertical surface of the apparatus including the rear door. The tillerman cab and rear bumper will not be covered.

The colors will be
ruby red
and
black
reflective.

Each stripe will be

6.00 " in width.
0596383
Stripe, Reflective/Diamond Grade, 6"
on Stabilizers

REFLECTIVE STRIPE ON STABILIZERS
There will be a

6.00 " wide
black
reflective stripe provided on the forward and rear facing side of all aerial stabilizers.
0567374
Stripe, Black Outline each Chevron
Stripe @ Rear (Not Warranted)

REFLECTIVE STRIPE OUTLINE
A black vinyl outline will be provided for each chevron stripe at the rear of the truck.

There will be no warranty provided for this material.
0065687
Stripe, Reflective, Cab Doors Interior

CAB DOOR REFLECTIVE STRIPE
A

6.00 " x

16.00 "
black
reflective stripe will be provided across the interior of each cab door. The stripe will be located approximately

1.00 " up from the bottom, on the door panel.

This stripe will meet the current edition of applicable NFPA standards. 0543998
Stripe, Reflective, Tillerman Doors
Interior

REFLECTIVE STRIPE, TILLERMAN DOORS
A

6.00 " x

16.00 "
black
reflective stripe will be provided across the interior of each tillerman's entry door. The stripe will be located approximately

1.00 " up from the bottom, on the door panel.

This stripe will meet the NFPA
1901
requirement.
0679822
Stripe, Sign Gold, Two-Tone Paint
Break with Shield, IPO Chrome
Molding

CAB STRIPE
There will be a Sign Gold stripe provided on both sides of the cab in place of the chrome molding and on the cab face with shield.
89 989
Bid #:

Page 410 of 519 ends

0679906
Stripe, Sign Gold, Box, Boom Sign
with Scrolls, Aerial

BOOM SIGN STRIPING
There will be Sign Gold stripes along all edges of the aerial boom sign. The stripes will have an outline and a scroll at each corner.
0594559
Lettering Specifications, (Sign Gold
Process)

LETTERING
The lettering will be
22 karat gold vinyl.
0685936
Lettering, Sign Gold, 3.00", Each

LETTERING
There will be sign gold lettering,

3.00 " high, with
outline and shade
provided. There will be
22 letters
provided.
0685732
Lettering, Sign Gold, 14.00", Each

LETTERING
There will be sign gold lettering,

14.00 " high, with
outline
provided. There will be
six (
6 )
letters
provided.
0685750
Lettering, Sign Gold, 9.00", Each

LETTERING
There will be sign gold lettering,

9.00 " high, with
outline and shade
provided. There will be
22 letters
provided.
0685793
Lettering, Sign Gold, 7.00", Each

LETTERING
There will be sign gold lettering,

7.00 " high, with
outline and shade
provided. There will be
four
(
4 ) letters
provided.
0685800
Lettering, Sign Gold, 6.00", Each

LETTERING
There will be sign gold lettering,

6.00 " high, with
outline and shade
provided. There will be
six (
6 )
letters
provided.
0685817
Lettering, Sign Gold, 4.00", Each

LETTERING
There will be sign gold lettering,

4.00 " high, with
outline and shade
provided. There will be
seven
(
7 ) letters
provided.
0778135
SP
Laminate Lettering on Entire unit for
Protection with Goldstar cut

LAMINATE LETTERING ON ENTIRE UNIT WITH GOLDSTAR CUT
The lettering on the entire unit will be completely covered with a clear plastic laminate material to protect it and with a goldstar cut.
0655896
Sign Kit, Painted, Holder and Insert,
Each

SIGN KIT FOR LETTERING/NUMERALS
four (
4 )
painted stainless steel plate(s) and holder(s) will be provided for department lettering.

They will be mounted
to be determined at precon
and

9.75 "W X
11 "H on the cab sides & front
bumper.
in size.
0530793
Emblem, American Flag, Flat (Not
Moving), Pair, Mirror Images

EMBLEMS
There will be
one (
1 )
pair of American flag emblems,

12.00 "
high, installed
Located on the
gooseneck section of the tiller.
. The flag will be flat (not moving) and made out of vinyl material.

The pair will be mirror images of each other.
0755303
Artwork File, Provided on Custom
USB Drive

ARTWORK ON CUSTOM USB DRIVE
There will be a custom USB drive with department specific artwork files provided to the Fire Department.

Stock artwork, or artwork developed exclusively by Pierce Manufacturing, and proprietary fonts will not be included on the USB drive.
0684199
Emblem, Maltese Cross, Sign Gold,
15"-17", Pair

EMBLEMS
There will be
one (
1 )
pair of maltese crosses, comprised of sign gold material, provided and installed
Cab Doors, match
38759
.
90 989
Bid #:

Page 411 of 519 ends

0529225
Manuals, Two (2) CD, Fire Apparatus
Parts, Custom Chassis

FIRE APPARATUS PARTS CD MANUAL
There will be two (
2 ) custom parts manuals for the complete fire apparatus provided in CD format with the completed unit.

The manuals will contain the following:

Job number
Part numbers with full descriptions
Table of contents
Parts section sorted in functional groups reflecting a major system, component, or assembly Parts section sorted in alphabetical order
Instructions on how to locate parts
The manuals will be specifically written for the chassis and body model being purchased. It will not be a generic manual for a multitude of different chassis and bodies.

Service Parts Internet Site
The service parts information included in these manuals are also available on the factory website.

The website offers additional functions and features not contained in this manual, such as digital photographs and line drawings of select items. The website also features electronic search tools to assist in locating parts quickly.
0543577
Manuals, (1) Chassis Service & (1)
CD, Custom

CHASSIS SERVICE MANUALS
One (
1 ) chassis service manuals containing parts and service information on major components will be provided with the completed unit.

One (
1 ) compact disk (CD) will also be provided that will include all of the information from the above manual.

The manuals will contain the following sections:
- Job number
- Table of contents
- Troubleshooting
- Front Axle/Suspension
- Brakes
- Engine
- Tires
- Wheels
- Cab
- Electrical, DC
- Air Systems
- Plumbing
- Appendix
The manual will be specifically written for the chassis model being purchased. It will not be a generic manual for a multitude of different chassis and bodies. 0531638
Manual, Two (2) CD, Chassis
Operation, Custom, English

CHASSIS OPERATION CD MANUALS
There will be two (
2 ) CD format chassis operation manuals provided. Manuals will be in the English language.
0030008
Warranty, Basic, 1 Year, Apparatus,
WA0008
ONE (
1 ) YEAR MATERIAL AND WORKMANSHIP
A Pierce basic apparatus limited warranty certificate, WA 0008
, is included with this proposal.
0611136
Warranty, Chassis, 3 Year,
Velocity/Impel, WA0284

THREE (
3 ) YEAR MATERIAL AND WORKMANSHIP
The Pierce custom chassis limited warranty certificate, WA 0284
, is included with this proposal.
0696698
Warranty, Engine, Cummins, 5 Year,
WA0181

ENGINE WARRANTY
A Cummins
five (
5 ) year
limited engine warranty will be provided. A limited warranty certificate, WA
0181
, is included with this proposal.
0684953
Warranty, Steering Gear, Sheppard
M110, 3 Year WA0201

STEERING GEAR WARRANTY
A Sheppard
three (
3 ) year
limited steering gear warranty will be provided. A copy of the warranty certificate will be submitted with this proposal.
0595767
Warranty, Frame, 50 Year,
Velocity/Impel, WA0038

FIFTY (
50 ) YEAR STRUCTURAL INTEGRITY
The Pierce custom chassis frame and crossmembers limited warranty certificate, WA 0038
, is
included with this proposal.
0595698
Warranty, Axle, 3 Year, TAK-4,
WA0050

FRONT AXLE THREE (
3 ) YEAR MATERIAL AND WORKMANSHIP WARRANTY
The Pierce TAK-
4 suspension limited warranty certificate, WA
0050
, is included with this proposal.
0733306
Warranty, Single Axle, 5 Year,
Meritor, General Service, WA0384

SINGLE REAR AXLE FIVE (
5 ) YEAR MATERIAL AND WORKMANSHIP WARRANTY
A Meritor
™
Axle
5 year limited warranty will be provided.
91 989
Bid #:

Page 412 of 519 ends

0652758
Warranty, ABS Brake System, 3
Year, Meritor Wabco, WA0232

ABS BRAKE SYSTEM THREE (
3 ) YEAR MATERIAL AND WORKMANSHIP

WARRANTY
A Meritor Wabco
™
ABS brake system limited warranty certificate, WA
0232
, is included with this
proposal.
0019914
Warranty, Structure, 10 Year, Custom
Cab, WA0012
TEN (
10 ) YEAR STRUCTURAL INTEGRITY
The Pierce custom cab limited warranty certificate, WA
0012
, is included with this proposal.
0744240
Warranty, Paint, 10 Year, Cab, Pro-
Rate, WA0055
TEN (
10 ) YEAR PRO-RATED PAINT AND CORROSION
A Pierce cab limited pro-rated paint warranty certificate, WA 0055
, is included with this proposal.
0524627
Warranty, Electronics, 5 Year, MUX,
WA0014
FIVE (
5 ) YEAR MATERIAL AND WORKMANSHIP
The Pierce Command Zone electronics limited warranty certificate, WA 0014
, is included with this
proposal.
0695416
Warranty, Pierce Camera System,
WA0188

CAMERA SYSTEM WARRANTY
A Pierce fifty four (
54 ) month
warranty will be provided for the camera system
.
0647720
Warranty, Pierce LED Strip Lights,
WA0203

COMPARTMENT LIGHT WARRANTY
The Pierce
12 volt DC LED strip lights limited warranty certificate, WA 0203
, is included with this
proposal.
0046369
Warranty, 5-year EVS Transmission,
Standard Custom, WA0187

TRANSMISSION WARRANTY
The transmission will have a
five (
5 ) year/unlimited mileage
warranty covering
100
percent
parts and labor. The warranty will be provided by Allison Transmission.

Note: The transmission cooler is not covered under any extended warranty you may be getting on your Allison Transmission. Please review your Allison Transmission warranty for coverage limitations.
0685945
Warranty, Transmission Cooler,
WA0216

TRANSMISSION COOLER WARRANTY
The transmission cooler will carry a five (
5 ) year parts and labor warranty (exclusive to the
transmission cooler). In addition, a collateral damage warranty will also be in effect for the first three (
3 ) years of the warranty coverage and will not exceed
$10,000
per occurrence. A copy of
the warranty certificate will be included with this proposal. 0688798
Warranty, Water Tank, Lifetime, UPF,
Poly Tank, WA0195

WATER TANK WARRANTY
A UPF poly water tank limited warranty certificate, WA
0195
, is included with this proposal.
0596025
Warranty, Structure, 10 Year, Body,
WA0009
TEN (
10 ) YEAR STRUCTURAL INTEGRITY
The Pierce apparatus body limited warranty certificate, WA 0009
, is included with this proposal.
0693126
Warranty, AMDOR, Roll-up Door, 10
Year/5 Year Painted, WA0185

ROLL UP DOOR MATERIAL AND WORKMANSHIP WARRANTY
An AMDOR roll-up door limited warranty will be provided. The roll-up door will be warranted against manufacturing defects for a period of
ten (
10 ) years
. A
five (
5 ) year
limited warranty will
be provided on painted roll up doors.

The limited warranty certificate, WA
0185
, is included with this proposal.
0734463
Warranty, Pump, Waterous, 7 Year
Parts, WA0382

PUMP WARRANTY
The Waterous pump will be provided with a seven (
7 ) year
material and workmanship limited
warranty.

A copy of the warranty certificate will be included with this proposal. 0648675
Warranty, 10 Year S/S Pumbing,
WA0035
TEN (
10 ) YEAR PUMP PLUMBING WARRANTY
The Pierce apparatus plumbing limited warranty certificate, WA 0035
, is included with this
proposal.
0641372
Warranty, Foam System, Not
Available
0006999
Warranty, Structure, 20 Year, Aerial
Device, WA0052

TWENTY (
20 ) YEAR AERIAL DEVICE STRUCTURAL INTEGRITY WARRANTY
The Pierce device limited warranty certificate, WA
0052
, is included with this proposal.
92 989
Bid #:

Page 413 of 519 ends

0687388
Warranty, Swivels, 5 Year, Aerial
Device, WA0197

AERIAL SWIVEL WARRANTY
An Amity five (
5 ) year limited swivel warranty will be provided. A copy of the warranty certificate will be included with this proposal.
0088889
Not Required, Additional Aerial
Warranty
0687327
Warranty, Waterway, 10 Year, Aerial
Device, WA0198

AERIAL WATERWAY WARRANTY
An Amity ten (
10 ) year limited waterway warranty will be provided. A copy of the warranty certificate is included with this proposal.
0595860
Warranty, Paint, 4 Year, Aerial
Device, Pro-Rated, WA0047

FOUR (
4 ) YEAR PRO-RATED PAINT AND CORROSION
A Pierce aerial device limited pro-rated paint warranty certificate, WA 0047
, is included with this
proposal.
0725636
Warranty, Harrison Generator, 2 Year

TWO (
2 ) YEAR GENERATOR MATERIAL AND WORKMANSHIP WARRANTY
A Harrison Hydra-Gen generator two (
2 ) year
limited warranty will be provided.
0595820
Warranty, Paint, 10 Year, Body, Pro-
Rate, WA0057
TEN (
10 ) YEAR PRO-RATED PAINT AND CORROSION
A Pierce body limited pro-rated paint warranty certificate, WA 0057
, is included with this proposal.
0595412
Warranty, Graphics Lamination, 1
Year, Apparatus, WA0168

ONE (
1 ) YEAR MATERIAL AND WORKMANSHIP
The Pierce graphics fading and deterioration limited warranty limited warranty certificate, WA
0168
, is included with this proposal.
0819254
Certification, Vehicle Stability,
CD0196

VEHICLE STABILITY CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the apparatus complies with NFPA
1900
, current edition, section

7.14 , Vehicle Stability. The certification is included with this proposal.
0808577
Certification, Engine Installation,
Velocity, Cummins X15, 2027

ENGINE INSTALLATION CERTIFICATION
The fire apparatus manufacturer will provide a certification, along with a letter from the engine manufacturer stating they approve of the engine installation in the bidder's chassis. The certification will be provided at the time of delivery. 0686786
Certification, Power Steering,
CD0098

POWER STEERING CERTIFICATION
The fire apparatus manufacturer will provide a certification stating the power steering system as installed meets the requirements of the component supplier. The certification is included with this proposal.
0892701
Certification, Cab Integrity,
Impel/Velocity FR, CD0190

CAB INTEGRITY CERTIFICATION
The fire apparatus manufacturer will provide a cab crash test certification with this proposal. The certification will state that a specimen representing the substantial structural configuration of the cab has been tested and certified by an independent third party test facility. Testing events will be documented with photographs, real-time and high-speed video, vehicle accelerometers, cart accelerometers, and a laser speed trap. The fire apparatus manufacturer will provide a state licensed professional engineer to witness and certify all testing events. Testing will meet or exceed the requirements below:

SAE J
2422
Cab Roof Strength Evaluation - Quasi-Static Loading Heavy Trucks.

European Occupant Protection Standard ECE Regulation No. 29 .

SAE J
2420
COE Frontal Strength Evaluation - Dynamic Loading Heavy Trucks.

Side Impact
The cab will be subjected to dynamic preload where a
14,320
-lb moving barrier is slammed into
the side of the cab at

5.50 mph, striking with an impact of
13,000
ft-lb of force. This test is part of
the SAE J
2422
test procedure and more closely represents the forces a cab will see in a rollover incident.

Roof Crush
The same cab will be subjected to a roof crush force of 22,050
lb. This value meets the ECE
29 criteria and is equivalent to the front axle rating up to a maximum of ten ( 10 ) metric tons.

Additional Roof Crush
The same cab will be subjected to a roof crush force of 100,000
lb. (Four and a half times the
load criteria of ECE
29 )
Frontal Impact
The same cab will withstand a frontal impact of
32,600
ft-lb of force using a moving barrier in
accordance with SAE J
2420
.

Additional Frontal Impact
The same cab will withstand a frontal impact of
65,200
ft-lb of force using a moving barrier.
(Twice the force required by SAE J
2420
)
The same cab will withstand all tests without any measurable intrusion into the survival space of the occupant area.
93 989
Bid #:

Page 414 of 519 ends

0548950
Certification, Cab Door Durability,
Velocity/Impel, CD0001

CAB DOOR DURABILITY CERTIFICATION
Robust cab doors help protect occupants. Cab doors will survive a 200,000
-cycle door slam test
where the slamming force exceeds
20 G's of deceleration. The bidder will certify that the sample doors similar to those provided on the apparatus have been tested and have met these criteria without structural damage, latch malfunction, or significant component wear. 0548967
Certification, Windshield Wiper
Durability, Impel/Velocity, CD0005

WINDSHIELD WIPER DURABILITY CERTIFICATION
Visibility during inclement weather is essential to safe apparatus performance. Windshield wipers will survive a
3 million cycle durability test in accordance with section

6.2 of SAE J
198

Windshield
Wiper Systems - Trucks, Buses and Multipurpose Vehicles.

The bidder will certify that the wiper
system design has been tested and that the wiper system has met these criteria. 0667411
Certification, Electric Window
Durability, Velocity/Impel FR,
CD0004

ELECTRIC WINDOW DURABILITY CERTIFICATION
Cab window roll-up systems can cause maintenance problems if not designed for long service life. The window regulator design will complete
30,000
complete up-down cycles and still function
normally when finished. The bidder will certify that sample doors and windows similar to those provided on the apparatus have been tested and have met these criteria without malfunction or significant component wear.
0549273
Certification, Seat Belt Anchors and
Mounting, Imp/Vel/Vel SLT, CD0018

SEAT BELT ANCHOR STRENGTH
Seat belt attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat belt anchor design will withstand 3000
lb of pull on both
the lap and shoulder belt in accordance with FMVSS
571.210
Seat Belt Assembly Anchorages.

The bidder will certify that each anchor design was pull tested to the required force and met the appropriate criteria.

SEAT MOUNTING STRENGTH
Seat attachment strength is regulated by Federal Motor Vehicle Safety Standards and should be validated through testing. Each seat mounting design will be tested to withstand 20 G's of force in
accordance with FMVSS
571.207
Seating Systems. The bidder will certify that each seat mount and cab structure design was pull tested to the required force and met the appropriate criteria. 0735950
Certification, Cab HVAC System Perf,
Vel/Imp FR,
CD0166/CD0168/CD0176/CD0177

PERFORMANCE CERTIFICATIONS
Cab Air Conditioning
Good cab air conditioning temperature and air flow performance keeps occupants comfortable, reduces humidity, and provides a climate for recuperation while at the scene. The cab air conditioning system will cool the cab from a heat-soaked condition at 100
degrees Fahrenheit to
an average of
78 degrees Fahrenheit in
30 minutes. The bidder will certify that a substantially similar cab has been tested and has met these criteria.

Cab Defroster
Visibility during inclement weather is essential to safe apparatus performance. The defroster system will clear the required windshield zones in accordance with SAE J 381
Windshield
Defrosting Systems Test Procedure And Performance Requirements - Trucks, Buses, And Multipurpose Vehicles.

The bidder will certify that the defrost system design has been tested in a cold chamber and passes the SAE J
381
criteria.

Cab Auxiliary Heater
Good cab heat performance and regulation provides a more effective working environment for personnel, whether in-transit, or at a scene. An auxiliary cab heater will warm the cab 77 degrees
Fahrenheit from a cold-soak, within
30 minutes when tested using the coolant supply methods found in SAE J
381
. The bidder will certify, at time of delivery, that a substantially similar cab has been tested and has met these criteria.
0545073
Amp Draw Report, NFPA Current
Edition

AMP DRAW REPORT
The bidder will provide, at the time of bid and delivery, an itemized print out of the expected amp draw of the entire vehicle's electrical system.

The manufacturer of the apparatus will provide the following:

Documentation of the electrical system performance tests.

A written load analysis, which will include the following:

The nameplate rating of the alternator.

The alternator rating under the conditions specified per:

Current edition of applicable NFPA standards.

The minimum continuous load of each component that is specified per:

Current edition of applicable NFPA standards.

Additional loads that, when added to the minimum continuous load, determine the total connected load.

Each individual intermittent load.

All of the above listed items will be provided by the bidder per the current edition of applicable NFPA standards.
0002758
Amp Draw, NFPA/ULC Radio
Allowance
0799248
Appleton/Florida BTO

0000029

TILLER BODY
94 989
Bid #:

Page 415 of 519 ends

0000012

PIERCE CHASSIS
0004713

ENGINE, OTHER
0046396
EVS 4000 Series TRANSMISSION
0020011

WATEROUS PUMP

0020009

POLY TANK

0028047

NO FOAM SYSTEM

0020006

SIDE CONTROL
0020007

AKRON VALVES

0020015

ABS SYSTEM

0658751

PUMPER BASE

95 989
Bid #:

Page 416 of 519 ends

Electrical Analysis
3/16/2026
Bid #:
989
107' w/pump & Tank Ascendant Velocity Tiller - City of
Turlock Fire (Duplicate to 43739)
Sales Rep:

Organization:

Young, Dewayne
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer:

Turlock Fire Department
Option:

Pierce Command Zone, Advanced Electronics & Control
System, Vel WiFi CZT
Type:

Multiplexed
Option
Description
Type*
Minimum
Load
Intermittent
Load
Total
Connected
0001244
High Idle w/Electronic Engine, Custom

0.00 1.20

0.00 0072153
Primer, Trident, Air Prime, Air Operated

0.00 0.00

0.00 0098841
Batteries, (6) Deka Grp 31, 1000 CCA each, Threaded Stud

0.00 3.00

0.00 0549333
Indicators, Engine, Included with Pressure Controller

0.00 0.35

0.00 0583824
Light, Pump Compt, Wln 3SC0CDCR LED White

0.00 0.72

0.00 0583938
Lights, Engine Compt, Custom, Auto Sw, Wln 3SC0CDCR, 3" LED, Trim

0.00 0.30

0.00 0589905
Alarm, Back-up Warning, PRECO 1040

0.00 0.50

0.00 0628472
Light, Map, Overhead, Peterson M371S LED, Rectangular
w/Switch 2lts

0.00 0.24

0.00 0629913
Lights, Stabilizer Pad Locator, Wln Micro MPB*, Rec Stb S Pn, Sw Ft

0.00 8.00

0.00 0652881
Lights, Dome, FRP Dual LED

0.00 0.00

0.40 0653350
Guards, Vehicle Camera(s), Painted Smooth Aluminum

0.00 0.00

0.00 0678715
Compt, At Rear Between Tow Eyes, Smooth Alum Sngl Pan Door w/D-Latch, Tiller

0.00 0.00

0.00 0687994
Engine Brake, Jacobs Compression Brake, Cummins Engine

0.00 0.42

0.00 0732223
Remote Start, Hydraulic Generator, 4 Locations

0.00 1.00

0.00 0770696
Aerial PTO Activated with Aerial Master Sw

0.00 0.00

0.08 0780137
Intercom, David Clark, 5-Pos, 2-Radio, (D,O,RPTT), 2obC, TC, 3805

0.00 0.00

0.50 0789602
Stabilizers, ASL Tractor Drawn Steel Aerial, Split Pan, 17' Spread

0.00 2.00

0.00 0804537
Lights, Cornering, Tiller, Wln, 704BU, 2 lts

0.00 1.00

0.00 0804781
Aerial Scene Lts Separated into Aerial Tip Category and Aerial Tracking Category

0.00 0.00

0.00 0805325
Light, Directional, Wln M62T* LED, 15 Degree Angle Bracket, Additional

0.00 1.50

0.00 0806466
Lights, Backup, Wln M62BU, LED, For Tail Lt Housing

0.00 3.20

0.00 0817058
Camera, Pierce, LS Mux, R Camera, SD, CL714

0.00 1.20

0.00 0821239
Wiring, Spare, 20 A 12V DC, 6 Ckt FB, Blue Sea 5025 Batt Dir 2nd NFPA1900/ULC

0.00 0.00

20.00 0821240
Wiring, Spare, 20 A 12V DC, 6 Ckt FB, Blue Sea 5025 Batt Dir 3rd NFPA1900/ULC

0.00 0.00

20.00 0821725
Wiring, Spare, 3 A 12V DC Batt Dir 1st NFPA1900/ULC

0.00 0.00

6.00 0822289
ABS/ATC Wabco Brake System, Single Axle, Tiller, NFPA
1900/ULC

0.00 6.00

0.00 0825970
Controls, Electric Windows, All Cab Doors, Impel/Velocity FR, Pnl 8 0.00

26.00 0.00
0834413
USB, Cab, 4, 12V DC, Dual USB Termination, Batt Dir.

NFPA1900/ULC

0.00 0.00

10.00 0895281
Siren, Federal Q2B, Littelfuse 24213 Sol

0.00 100.00

0.00 0895974
Lights, Door Interior Flash, 4 Dr Cab, Wln 3S*00F*R, 3" Round

0.00 2.00

0.00 0897669
Cab Lift, Elec/Hyd, w/Manual Override, Batt Swtich, Imp/Vel

0.00 180.00

0.00 0653677
Lighting, Rung, LED, TecNiq, 4 Section, Base, Lower/Upper Mid, Fly
Load Managed

0.00 0.00

7.20 0693551
Lights, Tractor Scene, Wln M9LZC LED, pair
Load Managed

0.00 0.00

12.00 0724595
Heater/Defroster, Tiller Cab, Electric, Dual 12V, 3 Spd, No Thermo, Med Climate
Load Managed

0.00 0.00

75.00 0725783
Lights, Centering, Cab Roof, Tlr, Clpsbl, Attwood NV2002SS-7, Red/Grn LED
Load Managed

0.00 0.00

1.44 0727540
Spotlight, Golight/RadioRay, Model 20**4GT, LED, 1 Lt
Load Managed

0.00 0.00

3.00 0727946
Lights, Wln, S30M** 30" 12VDC LED, RS Cab, Mt Fet
Load Managed

0.00 0.00

7.20 0736755
Light, Wln, 12V PSL2** Slm Ln, 12 VDC 1st
Load Managed

0.00 0.00

12.00 0741239
HVAC, Heavy-Duty, Impel/Velocity FR, CARE
Load Managed

0.00 0.00
136.00
0748793
Lights, Wln, S44M** 44" 12VDC, RS Body
Load Managed

0.00 0.00

32.40 0748795
Lights, Wln, S44M** 44" 12VDC, LS Body
Load Managed

0.00 0.00

32.40 0750408
Lights, Side, Wln PS*01FCR, 1st
Load Managed

0.00 4.80

3.20 0766481
Lights, Wln, PSL1** Pioneer, 12 VDC, 1st
Load Managed

0.00 0.00

6.00 0776357
Light, Visor, Wln, 12V P*H2* Pioneer, Cnt Feature, 1st
Load Managed

0.00 0.00

13.00 0783530
Mirrors, Ramco, 8000PCHR, All Heated/Remote, w/Convex, Dr Mnt, Add Wiring
Load Managed

0.00 0.00

8.00 0803462
Lights, Tip, Wln MP** LED, 2lts
Load Managed

0.00 0.00

7.03 0804719
Handlts, (4) Streamlight, Fire Vulcan, 44451, C4 LED, Tail Lts, 12v, Orange
Load Managed

0.00 0.00

4.40 * UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 1

Page 417 of 519 ends

Electrical Analysis
3/16/2026
Bid #:
989
107' w/pump & Tank Ascendant Velocity Tiller - City of
Turlock Fire (Duplicate to 43739)
Sales Rep:

Organization:

Young, Dewayne
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer:

Turlock Fire Department
Option:

Pierce Command Zone, Advanced Electronics & Control
System, Vel WiFi CZT
Type:

Multiplexed
Option
Description
Type*
Minimum
Load
Intermittent
Load
Total
Connected
0815635
Light, Wln, 12V PCPSM2*, 12 VDC, Rear Facing, Id Lts Rr Til Cab Spcl Brkt
Load Managed

0.00 0.00

12.00 0821261
Wiring, Spare, 20 A 12V DC, 12 Circuit Fuse Block Blue Sea 5026 2nd NFPA1900/ULC
Load Managed

0.00 0.00

20.00 0822831
Inverter/Battery Charger, Xantrex Frdm XC Pro 818-2010, Sw, NonNFPA 2024 100 Amp
Load Managed

0.00 0.00
195.31
0889659
Lights, Wln, S30M** 30" 12VDC LED, LS Cab, Mtg Fet
Load Managed

0.00 0.00

7.20 0898153
Lights, Wln, PSL1** Pioneer, 12 VDC, 2nd
Load Managed

0.00 0.00

6.00 0002565
Hourmeter, Aerial Inside Cab
NFPA

0.10 0.00

0.00 0002615
Switch, Aerial 12V Master
NFPA

0.08 0.00

0.00 0002758
Amp Draw, NFPA/ULC Radio Allowance
NFPA

5.00 0.00

0.00 0010758
Flow Meter, Waterway, PAL, 110' Ascendant, MUX
NFPA

0.50 0.00

0.00 0059809
Light, Marker, Weldon, 9186-1500 LED, Location
NFPA

0.10 0.00

0.00 0068703
Lights, Grote Supernova LED, Stabilizer Beam, (1) Set
NFPA

1.60 0.00

0.00 0092582
Load Manager/Sequencer, MUX
NFPA

0.56 0.56

0.00 0534828
Siren, Wln 295SL101, 100 or 200W Removable Mic
NFPA

0.80 7.20

0.00 0534987
Lights, Clearance/Marker/ID, Rear, Truck-Lite 33050R LED 7Lts, Aerial
NFPA

0.35 0.00

0.00 0536401
Gauges, Engine, Included With Pierce Pressure Controller NFPA

0.30 0.00

0.00 0540439
Light, Front Zone, Wln M6* LED, Colored Lens 2Lts
NFPA

1.80 2.70

0.00 0540725
Lights, Stabilizer Warn (1) Set, Wln M6* LED, Rear Colored Lens NFPA

1.80 2.70

0.00 0555915
Wiper Control, 2-Speed with Intermittent, MUX, Impel/Velocity NFPA

2.10 8.40

0.00 0564654
Lights, Rear Zn Lwr, Wln M6*, Colored Lens, For Tail Light Housing
NFPA

1.80 2.70

0.00 0568012
Air Dryer, Wabco System Saver 1200, Heater, 2010
NFPA

7.81 0.00

0.00 0568369
Cab Instruments, Ivory Gauges, Chrome Bezels, Impel/Velocity 2010
NFPA

1.26 0.00

0.00 0593161
Light Shield, S/S LED
NFPA

3.00 0.00

0.00 0601949
Light, Turntable Console, TecNiq T-10, LED Strip Light
NFPA

0.20 0.00

0.00 0601972
Lights, Turntable Walkway, P25, LED
NFPA

0.35 0.00

0.00 0601980
Lights, Stabilizer Scene, (1) set, Truck-Lite 40227C, Incandescent NFPA

2.88 0.00

0.00 0602102
Lights, Torque Box Ladder Storage, Truck-Lite 44042C 2lts, LED, Round 4"
NFPA

1.00 0.00

0.00 0604784
Lightbar, Wln, Freedom IV-Q, 81", RRRRWRsrROptRsrRWRRRR NFPA

8.96 2.68

9.92 0605126
Pump Shift, Air Mnl Override, Split Shaft, Interlocked, Waterous NFPA

1.00 0.00

0.00 0606017
Light, Do Not Move Apparatus, Wln VTX609R Red LED 2lts, DS PS Indicator
NFPA

0.60 0.90

0.00 0620054
Light, Directional/Marker, Intermediate, Weldon 9186-8580-29 LED 2lts
NFPA

0.10 0.90

0.00 0621947
Light, Rear Zone Up, Wln Rota-Beam R316*F LED Beacon, Color Lens
NFPA

4.50 0.00

0.00 0636262
Light, Dome, Weldon Dual LED 1lt
NFPA

2.00 2.00

0.00 0647245
Cab, Velocity FR, 6000
NFPA

6.80 10.20

0.00 0647647
Lights, Dome, FRP Dual LED 4 Lts
NFPA

0.80 0.80

0.00 0648074
Lights, Clearance/Marker/ID, Front, P25 LED 7 Lts
NFPA

0.49 0.00

0.00 0648630
Lights, Perimeter Cab, TecNiq E10-WS00-1 LED 4Dr, Angled Brkt NFPA

3.00 0.00

0.00 0649150
Generator, Harrison 10kW Hydraulic, Hot Shift PTO, IHT System NFPA

53.47 1.53

0.00 0653937
Flasher, Headlight Alternating
NFPA

0.08 0.00

0.00 0658406
Light, Marker, Britax Rubber Arm, Model 427.200.LB,
Amber/Amber, Qty/Loc
NFPA

2.00 0.00

0.00 0667186
Light, Slide-Out Pump Operator Step, OSS Access LED, Short Step
NFPA

0.65 0.00

0.00 0680193
Ladder Storage, Vertically Hinged Doors, Smooth Alum, Grabber Door Brkt, Tiller
NFPA

0.90 0.00

0.90 0683224
Compt, F/H, Trans Front, Roll, 6.00" Raised, RS Center, Tiller NFPA

1.80 0.00

1.80 0683225
Compt, F/H, Trans Roll, Special Width, 6.00" Raised, 92.00" Wide,RS Front,Tiller
NFPA

1.80 0.00

1.80 0683228
Compt, F/H, Trans Front, Roll, 6.00" Raised, LS Center, Tiller NFPA

1.80 0.00

1.80 0683231
Compt, F/H, Trans Roll, Special Width, 6.00" Raised, 92.00" Wide, LS Front
NFPA

1.80 0.00

1.80 0709438
Lights, Walk Surf, FRP Flood, LED
NFPA

2.00 0.00

0.00 0721094
Lights, Hose Bed, Not Required, No Hose Bed/Cargo Area
NFPA

1.36 0.00

0.00 0721609
Controller, Pressure, Pierce LCD, Custom Chassis
NFPA

1.70 0.00

0.00 * UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 2

Page 418 of 519 ends

Electrical Analysis
3/16/2026
Bid #:
989
107' w/pump & Tank Ascendant Velocity Tiller - City of
Turlock Fire (Duplicate to 43739)
Sales Rep:

Organization:

Young, Dewayne
Golden State Fire Apparatus, Inc
Desc:

Job #:

Customer:

Turlock Fire Department
Option:

Pierce Command Zone, Advanced Electronics & Control
System, Vel WiFi CZT
Type:

Multiplexed
Option
Description
Type*
Minimum
Load
Intermittent
Load
Total
Connected
0724821
Intercom, 2-Way Fire Research ICA910 Hands Free (Special Location, Con)
NFPA

0.50 0.00

0.00 0739224
Indicator Light @ Pump Panel, Throttle Ready, Incl w/Pressure Gov/Throttle,Green
NFPA

0.10 0.00

0.00 0745568
Indicator Light, Pump Panel, Ok To Pump, Green
NFPA

0.10 0.00

0.00 0747228
Lights, Side Zone Lower, Wln M6**, M6**, M6**, 6Lts
NFPA

5.40 8.10

0.00 0750526
Gauge, Water Level, Pierce, In pressure Controller, Lt Driver NFPA

1.23 0.00

0.00 0755072
Aerial, 107' ASL, 750/500 Tip, 50 MPH Wind, Tiller
NFPA

5.00 0.00

0.00 0762413
Light, Boom Support, Amdor AY-LB-12HW012, 12" LED
NFPA

0.18 0.00

0.00 0763582
DEF Tank, 4.5 Gallon, DS Fill, Forward of Rear Axle, Tiller NFPA

0.60 11.40

0.00 0765826
Cabinet, Rear Facing, LS, 30.5 W x 30 H x 24 D, Ext Acc Only, Imp/Vel
NFPA

0.56 0.56

0.00 0769564
Lights, Perimeter Pump House, Amdor AY-LB-12HW020 LED 1lt NFPA

0.30 0.00

0.00 0770200
Handrail, Exterior, Hansen, Knurled, Alum, LED Backlit, 4-Door Cab
NFPA

0.80 0.00

0.00 0780173
Lights, Perimeter, TecNiq E10-WS00-1 6.39" LED
NFPA

4.40 0.00

0.00 0783153
Headlights, Rect LED, JW Spkr Evo 2, AXT/Enf/Imp/Sab/Vel NFPA

4.20 4.20

0.00 0784035
Cpt,Low F/D Frt Roll/Lift,Low Rr Lap,Spc Stp,10" Rsd Fend,6" Rsd Bd,4" Rsd Flr
NFPA

3.60 0.00

3.60 0784038
Cpt,Low F/D Frt Roll,3 Lifts,Low Rr Lap,Spc Stp,10" Rsd Fend,6" Rsd Bd,4"Rsd Flr
NFPA

3.60 0.00

3.60 0791528
Light, Traffic Directing, Wln TAL65, 36.00" Long, TACTL5 NFPA

0.60 1.20

0.00 0802753
Lights, Tracking, Wln MP** LED, 2lts
NFPA

8.00 0.00

0.00 0804514
Lights, Tail, Wln M62BTT* Red Stop/Tail & M62T* Amber Dir Arw For Hsg
NFPA

0.83 2.49

0.00 0808499
Engine, Cummins X15, 565 hp, 1850 lb-ft, W/OBD, EPA 2027, Velocity
NFPA

6.00 0.00

0.00 0813525
Lights, Step, P25 LED, Tiller, Control, Trim Feature
NFPA

0.50 0.00

0.00 0814201
Vehicle Information Center, 7" Color Display, Touchscreen, MUX, CL714
NFPA

1.20 0.00

0.00 0814632
Control Stations, ASL Tiller, MUX, Color Display, CL714 NFPA

4.26 0.00

0.00 0815943
Cabinet, Rear Facing, RS, 26.5 W x 30 H x 21.5 D, Ext Acc Only, Sp Mtg, Imp/Vel
NFPA

0.30 0.30

0.00 0821860
Lights, Compt, Pierce LED, Dual Light Strips, Each Side of Door, All Compts
NFPA

11.52 0.00

0.00 0840425
Light, Directional, Wln 600 Cmb, Cab Crn, Wrp Bzl Out HD Lts, Imp/Vel
NFPA

1.15 1.15

0.00 0887546
Trans, Allison 6th Gen, 4000 EVS P, w/Prognostics,
Imp/Vel/SFR/Enf
NFPA

2.00 2.00

0.00 0888060
Lights, Perimeter Body, TecNiq E10-W000-1 4lts, Turntbl/Rr Stp, Tiller
NFPA

1.60 0.00

0.00 0889577
Bracket, License Plate & Light, P25 LED, Stainless Brkt NFPA

0.07 0.00

0.00 0892637
Lights, Cab & Crw Cab Acs Stps, P25, LED w/Bezel, 1Lt Per Step NFPA

1.00 0.00

0.00 0647728
Alternator, 430 amp, Delco Remy 55SI
S

0.00 0.00

0.00 Load Totals:
200.60
418.10
682.98
Minimum Continuous Load
Supply:
253.00
Demand:
200.60
Variance:

52.40 Total Connected Load
Supply:
369.00
Demand:
282.80
Variance:

86.20 Note: Minimum Continous Load is in "Blocking Right of Way" mode.(Reference current edition of NFPA/ULC) Note: Intermittent Load items are not factored in on any alternator load comparisons. These items are included on the report for reference only and should be looked at as amp draw exclusion items. (Reference current edition of NFPA/ULC) Note: Total Connected Load "Demand" represents Total Connected Load minus any Load Managed items 253.00
369.00
Alternator Output at Idle:

Alternator Output at Governed Speed:
* UDMC = User Defined Mission Critical, LM = User Defined Load Managed, S = Electrical Amperage Supply 3

Page 419 of 519 ends

Turning Performance Analysis
Bid Number:
989
Chassis:

Velocity Tractor Chassis (Tiller), (Big Block), 2010
Department:

Turlock Fire Department
Body:

Aerial, Tiller, Alum Body
Parameters:
*Inside Cramp Angle:
45°
Axle Track:

82.92 in.

Wheel Offset:

5.3 in.

Tread Width:

16.3 in.

Chassis Overhang:

65.99 in.

Additional Bumper Depth:
10 in.

Front Overhang:

75.99 in.

Wheelbase:
176 in.

Calculated Turning Radii:

Inside Turn:
13 ft. 7 in.

Curb to curb:
27 ft. 3 in.

Wall to wall:
30 ft. 11 in.

Notes:
*Actual Inside cramp angle may be less than shown.

Curb to Curb turning radius calculated for 9.00 inch curb. 03/16/2026
Category
Option
Description
Tires, Front
0899288
Tires, Front, Goodyear, Armor MAX MSA, 425/65R22.50, 20 ply, Fire Service Speed
Wheels, Front
0019618
Wheels, Front, Alcoa, 22.50" x 13.00", Aluminum, Hub Pilot Aerial Devices
0755072
Aerial, 107' ASL, 750/500 Tip, 50 MPH Wind, Tiller
Bumpers
0790541
Bumper, 10" Ext, Fab, .25" Steel, Painted, 12" H, Imp/Vel Axle, Front, Custom
0508849
Axle, Front, Oshkosh TAK-4, Non Drive, 22,800 lb, Imp/Vel

Page 420 of 519 ends

Definitions:

Inside CrampAngle
Maximum turning angle of the front inside fire.

Axle Track
King-pin to King-pin distance of front axle.

Wheel Offset
Offset from the center line of the wheel to the King-pin.

Tread Width
Width of the tire tread.

Chassis Overhang
Distance of the center line of the front axle to the front edge of the cab. This does not include the bumper depth.

Additional Bumper Wheel
Depth that the bumper assembly adds to the front overhang.

Wheelbase
Distance between the center lines of the vehicles front and rear axles.

Inside Turning Radius
Radius of the smallest circle around which the vehicle can turn.

Curb to Curb Turning Radius
Radius of the smallest circle around which the vehicle's tires can turn. This measures assumes a curb height of 9 inches.

Wall to Wall Turning Radius
Radius of the smallest circle around which the vehicle's tires can turn. This measures takes into account any front overhang due to chassis , bumper extensions and or aerial devices.

Page 421 of 519 ends

JROGHQVWDWHĆUHFRP

PRODUCT

WARRANTIES
Exhibit “C”
4

Page 422 of 519 ends

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/8/2010 WA0008

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

No specific exclusions apply
Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Fire and Rescue Apparatus
Coverage:

One (1) Year Material and Workmanship
Basic Apparatus
Twelve (12) months.Warranty Period
Ends After:

The date the apparatus is placed in service, or 60 days from the original buyer invoice date, whichever comes first.Warranty Begins:

Portions of the apparatus manufactured by Pierce shall be free from defects in material and workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot;

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

Page 423 of 519 ends

Fire and Rescue Apparatus
Coverage:

Three (3) Year Material and Workmanship
Velocity and Impel Custom Chassis
Limited Warranty Limited Warranty Limited Warranty Limited Warranty Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Portions of the apparatus manufactured by Pierce shall be free from defects in material and workmanship

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date the apparatus is placed in service, or 60 days from the original buyer invoice date, whichever comes first. Warranty Begins:

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty applies, where applicable, to Goldstar lamination, defroster heater coil and motor blower assembly (excluding the FET PWM module), heater, air conditioning condenser coil and fan/motor assembly, air conditioning evaporator coil and motor blower assembly (excluding the drain pan pump and thermostat), under seat heaters coil and motor blower assembly (excluding the FET PWM module),
HVAC electronic switches, HVAC hoses and hard lines,
heater water valve, Pierce PS6 seat frames and hardware, Pierce One-Eleven mirrors, Pierce hands-free scba holder, cracking or color loss of roto-molded components, Meritor rear axle, Wabco ABS system, cab door handles, Standen
spring suspension components, and the gauge instrument
cluster.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGE S.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Three (3) Years, or
30,000 Miles, or
5000 Engine Hours
Warranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle.
7/2/2015 WA0284
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

Page 424 of 519 ends

Cummins Warranty
Worldwide
Fire Apparatus/Crash Trucks

Page 425 of 519 ends

Coverage
Products Warranted
This Warranty applies to new diesel Engines sold by
Cummins and delivered to the first user on or after
April 1, 2007, that are used in fire apparatus truck and crash truck* applications Worldwide.

Base Engine Warranty
The Base Engine Warranty covers any failures of the
Engine which result, under normal use and service,
from a defect in material or factory workmanship
(Warrantable Failure). This Coverage begins with the
sale of the Engine by Cummins and ends five years or
100,000 miles (160,935 kilometers), whichever occurs
first, after the date of delivery of the Engine to the first user .

Engine aftertreatment components included in the
Cummins Critical Parts List (CPL) and marked with a
Cummins part number are covered under Base Engine
Warranty.

Additional Coverage is outlined in the Emission
Warranty section.

These Warranties are made to all Owners in the
chain of distribution and Coverage continues to all
subsequent Owners until the end of the periods of
Coverage.

Cummins
Responsibilities
Cummins will pay for all parts and labor needed to
repair the damage to the Engine resulting from a
Warrantable Failure.

Cummins will pay for the lubricating oil, antifreeze,
filter elements, belts, hoses and other maintenance
items that are not reusable due to the Warrantable
Failure.

Cummins will pay for reasonable labor costs for
Engine removal and reinstallation when necessary to
repair a Warrantable Failure.

Cummins will pay reasonable costs for towing a
vehicle disabled by a Warrantable Failure to the
nearest authorized repair location. In lieu of the towing expense, Cummins will pay reasonable costs for
mechanics to travel to and from the location of the
vehicle, including meals, mileage and lodging when
the repair is performed at the site of the failure.

Owner
Responsibilities
Owner is responsible for the operation and
maintenance of the Engine as specified in Cummins
Operation and Maintenance Manuals. Owner is also
responsible for providing proof that all recommended
maintenance has been performed.

Before the expiration of the applicable Warranty,
Owner must notify a Cummins distributor ,authorized
dealer or other repair location approved by Cummins
of any Warrantable Failure and make the Engine
available for repair by such facility. Except for Engines disabled by a Warrantable Failure, Owner must also
deliver the Engine to the repair facility.

Service locations are listed on the Cummins Worldwide
Service Locator at cummins.com.

Owner is responsible for the cost of lubricating oil,
antifreeze, filter elements and other maintenance items provided during Warranty repairs unless such items
are not reusable due to the Warrantable Failure.

Owner is responsible for communication expenses,
meals, lodging and similar costs incurred as a result of a Warrantable Failure.

Owner is responsible for non-Engine repairs and for
‘‘downtime’’expenses, cargo damage, fines, all
applicable taxes, all business costs and other losses
resulting from a Warrantable Failure.

Owner is responsible for a $100 (U.S. Dollars)
deductible per each service visit under this plan in the 3rd, 4th and 5th years of Base Engine Warranty. The
deductible will not be charged during the first 2 years of the Base Engine Warranty.

Limitations
Cummins is not responsible for failures or damage
resulting from what Cummins determines to be abuse
or neglect, including, but not limited to: operation
without adequate coolants or lubricants; overfueling;
overspeeding; lack of maintenance of lubricating,
cooling or intake systems; improper storage, starting,
warm-up, run-in or shutdown practices; unauthorized
modifications of the Engine.

Any unauthorized modifications to the aftertreatment
could negatively effect emissions certification and void Warranty.

Cummins is also not responsible for failures caused by
incorrect oil, fuel or diesel exhaust fluid or by water , dirt or other contaminants in the fuel, oil or diesel

Page 426 of 519 ends

exhaust fluid.

This Warranty does not apply to accessories supplied
by Cummins which bear the name of another
company. Such non-warranted accessories include, but
are not limited to: alternators, starters, fans, air
conditioning compressors, clutches, filters,
transmissions, torque converters, vacuum pumps,
power steering pumps, fan drives and air compressors.

Cummins branded alternators and starters are covered
for the first two years from the date of delivery of the Engine to the first user ,or the expiration of the Base Engine Warranty, whichever occurs first.

Failures resulting in excessive oil consumption are not covered beyond the duration of the Coverage or
100,000 miles (160,935 kilometers) or 7,000 hours from
the date of delivery of the Engine to the first user ,
whichever of the three occurs first. Before a claim for excessive oil consumption will be considered, Owner
must submit adequate documentation to show that
consumption exceeds Cummins published standards.

Failures of belts and hoses supplied by Cummins are
not covered beyond the first year from the date of
delivery of the Engine to the first user or the duration of the Warranty, whichever occurs first.

Parts used to repair a Warrantable Failure may be new
Cummins parts, Cummins approved rebuilt parts or
repaired parts. Cummins is not responsible for failures resulting from the use of parts not approved by
Cummins.

A new Cummins or Cummins approved rebuilt part
used to repair a Warrantable Failure assumes the
identity of the part it replaced and is entitled to the remaining Coverage hereunder .

Cummins Inc. reserves the right to interrogate
Electronic Control Module (ECM) data for purposes of
failure analysis.

CUMMINS DOES NOT COVER WEAR OR WEAROUT
OF COVERED PARTS.

CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.

THIS W ARRANTYAND THE EMISSION W ARRANTY

SET FORTH HEREINAFTER ARE THE SOLE

W ARRANTIESMADE BY CUMMINS IN REGARD TO
THESE ENGINES. CUMMINS MAKES NO OTHER

W ARRANTIES,EXPRESS OR IMPLIED, OR OF

MERCHANT ABILITYOR FITNESS FOR A
P ARTICULARPURPOSE.

This Warranty gives you specific legal rights, and you
may also have other rights which vary from state to
state.

Emission
Warranty
Products Warranted
This Emission Warranty applies to new Engines
marketed by Cummins that are used in the United
States** in vehicles designed for transporting persons
or property on a street or highway. This Warranty
applies to Engines delivered to the first user on or after September 1, 1992.

Coverage
Cummins warrants to the first user and each
subsequent purchaser that the Engine is designed,
built and equipped so as to conform at the time of sale by Cummins with all U.S. federal emission regulations
applicable at the time of manufacture and that it is free from defects in material or factory workmanship which
would cause it not to meet these regulations within the longer of the following periods: (A) Five years or
100,000 miles (160,935 kilometers) of operation,
whichever occurs first, as measured from the date of
delivery of the Engine to the first user or (B) The Base Engine Warranty.

If the vehicle in which the Engine is installed is
registered in the state of California, a separate
California Emission Warranty also applies.

Limitations
Failures, other than those resulting from defects in
material or factory workmanship, are not covered by
this Warranty.

Cummins is not responsible for failures or damage
resulting from what Cummins determines to be abuse
or neglect, including, but not limited to: operation
without adequate coolants or lubricants; overfueling;
overspeeding; lack of maintenance of lubricating,
cooling or intake systems; improper storage, starting,
warm-up, run-in or shutdown practices; unauthorized
modifications of the Engine.

Any unauthorized modifications to the aftertreatment
could negatively effect emissions certification and void Warranty.

Cummins is also not responsible for failures caused by
incorrect oil, fuel or diesel exhaust fluid or by water , dirt or other contaminants in the fuel, oil or diesel
exhaust fluid.

Cummins is not responsible for non-Engine repairs,
‘‘downtime’’expenses, cargo damage, fines, all
applicable taxes, all business costs or other losses
resulting from a Warrantable Failure.

Page 427 of 519 ends

Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.

Bulletin 3381161
Printed in U.S.A. Rev. 08/09
©2001 Cummins Inc.

CUMMINS IS NOT RESPONSIBLE FOR INCIDENTAL
OR CONSEQUENTIAL DAMAGES.
* Airport operated crash trucks and fire department
operated trucks employed to respond to fires,
hazardous material releases, rescue and other
emergency-type situations.
** United States includes American Samoa, the
Commonwealth of Northern Mariana Islands, Guam,
Puerto Rico and the U.S. Virgin Islands.

Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.

Bulletin 3381161
Printed in U.S.A. Rev. 08/09
/H230052001 Cummins Inc.

Page 428 of 519 ends
Page 429 of 519 ends
Page 430 of 519 ends
Page 431 of 519 ends
Page 432 of 519 ends

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.

Fire and Rescue Apparatus
Coverage:

Lifetime Fifty (50) Year Structural Integrity
Chassis Frame & Crossmembers
Fifty (50) Years
(Expected Life of Apparatus)
Warranty Period
Ends After:

The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:

Custom chassis frame rail and cross members manufactured by Pierce shall be free from defects in material and
workmanship
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce. (b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Limited Warranty
Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 2/16/2010 WA0038

1. LIMITED WARRANTY
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This warranty does not apply to damage caused by corrosion.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

Page 433 of 519 ends

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

This limited warranty excludes brake pads, brake rotors, seal boots and shock absorbers.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGE S.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Three (3) Years
-or-
30,000 Miles
Warranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle.
12/16/2013 WA0050
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

Fire and Rescue Apparatus
Coverage:

Three (3) Year Material and Workmanship
TAK-4 Independent Front Suspension
Limited Warranty Limited Warranty Limited Warranty Limited Warranty Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The TAK-4 Front Independent Suspension and Steering
Gears shall be free from defects in material and
workmanship.

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory). Warranty Begins:

Page 434 of 519 ends

Fire and Rescue Apparatus
Coverage:

SUPPLIER
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The Meritor axle shall be covered by Meritor as indicated in the attached Meritor warranty coverage description

1. LIMITED WARRANTY
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the purchaser who first puts the product in service ("Buyer"):
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:

This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

The exclusions listed in the attached Meritor warranty
description shall apply.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4

4. EXCLUSION OF CONSEQUENTIAL AND INCIDENTAL DAMAGES.

Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.

3. BUYER'S EXCLUSIVE REMEDY.
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Five (5) YearsWarranty Period
Ends After:

Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle. 6/29/2020 WA0384
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES ALL

OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.

2. DISCLAIMERS OF WARRANTIES
The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

Page 435 of 519 ends

CUMMINS-MERITOR

COMMERCIAL

VEHICLE SYSTEMS

WARRANTY

COVERAGE FOR THE

UNITED STATES AND CANADA
MODEL YEAR 2024 VEHICLES

Page 436 of 519 ends

2 WARRANTY INFORMATION

TABLE OF CONTENTS
EFFECTIVE MODEL YEAR 2024 VEHICLES
Linehaul .......................................................................................................3 General Service ...........................................................................................6 Heavy Service/Specialty Vehicle ..................................................................9 Fire and Emergency ...................................................................................12 Transit Bus ................................................................................................ 14 Off-highway Service ...................................................................................15 Terms and Conditions ................................................................................17 How to Read Warranty Coverage
Number of Years Mileage (in thousands)
Unl = Unlimited
P = Parts Only
P&L = Parts and Labor
Notice:

Models or components that are approved for use by Cummins-Meritor’s vocational guidelines contained in Cummins-Meritor publication TP-9441 for axles, SP-8320 for trailer axles and TP-12126 for drivelines, or any other products that have an application approval completed with Cummins-Meritor which are not specifically listed, are warranted for one year, unlimited miles, parts only (1/Unl/P).

Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles, parts only (1/Unl/P).

Advantage Program
Purchasing additional coverage on select components will continue to safeguard your investment against major repair costs after the initial base coverage expires. You can find out more about the Advantage Program by visiting meritor.com or by contacting Cummins-Meritor at 866-OnTrac1 (866-668-7221) .

Page 437 of 519 ends

3 Linehaul Vehicles
Auto Hauler1
Bulk Hauler1
Chip Hauler1,2
Doubles
Flatbed
General Freight
Grain Hauler1
Livestock Hauler
Moving Van
Pipe Hauler
Refrigerated Freight
Tanker1
Triples
1 Cummins-Meritor classifies these vehicle types as high center of gravity, which require special axle housing considerations. 2 Chip Hauler vehicles require specific axle models listed below and Linehaul condition to be eligible for Linehaul warranty consideration.

Linehaul Typically Is:

High mileage operation (over 60,000 miles/year)
Greater than 30 miles between starts and stops
Maximum grades of 12%
Well maintained highways of concrete or asphalt construction (100% on-road)
Category A job sites, terminals, docks and transfer sites (defined as pavement, concrete or maintained and hard packed gravel).

Note: Category B job sites, terminals, docks, transfer sites (defined as loose or unmaintained sand, dirt or gravel; landfill; farm field; mud; or other similar surfaces) are NOT approved for certain linehaul axle models.

Front Non-Drive Steer Axles – 5/750/P&L
FD-965
FF-941
FF-942
FF-943
FF-944
FF-961
FF-966
FF-967
FG-941
FG-943
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122A-N
MFS-12-122B-N
MFS-12-122C-N
MFS-12E-122A-N
MFS-12E-122B-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12-132C-N
MFS-12E-132B-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12E-143A-N
MFS-12-144A-N
MFS-13-122A-N
MFS-13-122B-N
MFS-13-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-13B-122B-N
MFS-13B-122C-N
MFS-13B-132B-N
MFS-13B-132C-N
MFS-14-122A-N
MFS-14-122B-N
MFS-14F-122B-N
MFS-14G-122B-N
MFS-14-122C-N
MFS-14F-122C-N
MFS-14G-122C-N
MFS-14-124A-N
MFS-14-132B-N
MFS-14F-132B-N
MFS-14G-132B-N
MFS-14-132C-N
MFS-14F-132C-N
MFS-14G-132C-N
MFS-14-142B-N
MFS-14F-142B-N
MFS-14G-142B-N
MFS-14-142C-N
MFS-14F-142C-N
MFS-14G-142C-N
MFS-14-143A-N
MFS-14-144A-N
Rear Drive Single Axles – 5/750/P&L
MS-19-14X
RS-21-160
MS-23-17H1,2
MS-23-17X2
RS-23-160
RS-23-161
RS-23-185
RS-23-186
Coverage under Cummins-Meritor’s warranty require that
the application of products be properly approved pursuant to OEM and Cummins-Meritor approvals. Refer to TP-9441
for axles, SP-8320 for trailer axles, TP-12126 for drivelines and/or contact Cummins-Meritor regarding specific
application approval questions on any product line.

LINEHAUL

WARRANTY INFORMATION
Vocational Definition of Linehaul
Long distance hauling of food, goods and finished materials Not included are raw ferrous materials, minerals (except oil), sand, gravel, stone, rocks, topsoil, waste or logs Linehaul includes turnpike and hub & spoke
1 Not approved for use in any Category B job sites, terminals, docks or transfer sites. 2 Recommend 11 mm minimum wall thickness for these models used in combination with high center of gravity vehicles and trailing arm suspensions or vehicles operating mainly in Canada.

Page 438 of 519 ends

4 Trailer Axles1
Beam and Brackets 5/500/P , 1/100/L
TPX3000 Axle Series 2 10/Unl/P, 1/Unl/L
Wheel End Systems3
Standard System 4 1/100/P&L
AxlePak5 5/Unl/P&L
AxlePak7 5 7/Unl/P&L
1 For brake components and ABS coverage, refer to appropriate product warranties. 2 Structural components only excluding spindle wear. Spindle wear is 5/Unl/P, 1/Unl/L.
3 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage. 4 When installed by Cummins-Meritor.
5 When specified with AxlePak7 wheel end system, coverage on Meritor Tire Inflation System (MTIS) thru-tee and stator is 7/Unl/P, 1/Unl/L.

TAG/Pusher Axles1
TQ, TR Beam and Brackets 5/750/P&L
1 For brake components and ABS coverage, refer to appropriate product warranties.

Trailer Mechanical Suspension
Systems1
IMS40 (Integrated Mechanical Suspension – Tandem)2 1/Unl/P&L IMS20 (Integrated Mechanical Suspension – Single)2 1/Unl/P&L 1 For axle coverage, refer to appropriate product warranties. 2 All other suspension components refer to appropriate manufacturer’s warranty.

Trailer Air Suspension Systems
MPA40 (Tandem Axle Parallelogram)1
Major Structural Components 5/500/P, 1/100/L
Curbing Damage Warranty2 5/500/P , 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs 2/200/P , 1/100/L
Bushings 5/Unl/P , 3/Unl/L
PinLoc Air Controls 1/100/P&L
PinLoc Actuator 3/300/P&L
MPA20 (Single Axle Parallelogram)
Major Structural Components 5/500/P, 1/100/L
Height Control Valve 1/100/P&L
Shock Absorbers 2/200/P&L
Air Springs 2/200/P , 1/100/L
Bushings 5/Unl/P , 3/Unl/L
MTA and MTA-Tec6 Trailing Arm Suspension System
Major Structural Components 5/500/P, 1/100/L
Height Control Valve 1/100/P&L
Air Springs 2/200/P , 1/100/L
Bushings 5/500/P , 3/300/L
Shock Absorbers 2/200/P&L
Lift Kit System 1/100/P&L
1 Fastener torque coverage is limited to 2/Unl/P&L when torqued by Cummins- Meritor (For axle and ABS coverage, refer to appropriate product warranties.) 2 “Curbing damage” is defined as deformation (bending, buckling or breakage), caused by sudden impact with a curb or similar fixed object. Damage to the RideSentry slider box (the suspension sliding sub-frame consisting of the frame rails, cross-members and central A-frame assembly), caused by accidental trailer impact with a curb or similar fixed object, is eligible for warranty coverage. Damage to other components or resulting from collision with another vehicle, rollover or fire is not covered under this provision. Warranty is not transferable to another trailer VIN and coverage does not apply if the trailer is deemed to be a total loss, scrapped or otherwise not salvageable.

LINEHAUL

WARRANTY INFORMATION
Rear Drive Tandem/Tridem Axles – 5/750/P&L
RT-40-160/P1,2
RT-46-160/P1,2
RT-46-164/P1,2
RZ-1662
RT-50-160/P1,2
MA-40-165
MA-40-17H3
RZ-188
MA-40-175
MT-34-14X /P4
MT-40-14T/P
MT-40-14X /P4
MT-40-14X /P4
MT-40-14H/E3,4
1 These models required for Chip Hauler and Linehaul warranty consideration. 2 Each vehicle must have a Request for Application Recommendation (RAR) approved by Cummins-Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details. 3 Not approved for use in any Category B job sites, terminals, docks or transfer sites. 4 Recommend 11 mm minimum wall thickness for these models used in combination with high center of gravity vehicles and trailing arm suspensions or vehicles operating mainly in Canada.

Page 439 of 519 ends

5 LINEHAUL

WARRANTY INFORMATION
Brake Components
Cam Q Series Trailer Brakes 5/500/P , 1/100/L
Q+ Drum Brake™1 5/500/P , 1/Unl/P&L
ASA 5/500/P , 1/Unl/P&L
Hubs/Cast Drums and Other Wheel-End Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
STEELite X30 Drum Brake™2 12-Years or Wearable Life/P
EX+ L and EX+LS Air Disc Brake™3 5/500/P , 1/Unl/L
EX+L Air Disc Brake Extended Standard Warranty 3,4 5/500/P&L 1 For Trailer only, 3/300/P against rust jacking when equipped with Platinum Shield III.
2 Based on stamped wear diameter max.
3 Warranty coverage for boots, seals, caps, bushings and pins is 2/200/P.

Warranty coverage for pads is 1/100/P.
4 Applies only to calipers using friction: MA9300 (EX225LXXXCGXXX).

Drivelines
RPL 5/500/P , 1/Unl/P&L
MXL 3/350/P , 1/Unl/P&L
92N 1/Unl/P
Meritor Tire Inflation System
(MTIS)
MTIS Components 5/Unl/P , 1/Unl/L

Page 440 of 519 ends

6 General Service Vehicles
Auto Hauler
Beverage Truck
Bulk Hauler
Chip Hauler
Cross Country Coach
Flatbed
Front Engine Commercial
Chassis
Front Engine Integral Coach
General Freight
Grain Hauler
Intercity Coach
Intermodal Chassis
Livestock Hauler
Meat Packer
Moving Van
Municipal Truck
Newspaper Delivery
Pick-Up and Delivery
Pipe Hauler
Platform Auto Hauler
Rear Engine Integral Coach
Recreational Vehicles
Refrigerated Freight
School Bus
Stake Truck
Tanker
Tanker Trailer
Tour Bus
Wrecker
General Service Typically Is:

Typically, moderate mileage operation (less than 60,000 miles/year) An average of 3 to 30 miles between starts and stops
Maximum grades of 12%
Generally, on-road service (less than 10% off-road allowed) Category A job sites, terminals, docks and transfer sites (defined as pavement, concrete or maintained and hard packed gravel) or Category B job sites, terminals, docks and transfer sites (defined as loose or unmaintained sand, dirt or gravel; landfill; farm field; mud, or other similar surfaces)
Front Non-Drive Steer Axles – 2/Unl/P&L
FD-965
FF-941
FF-942
FF-943
FF-944
FF-946
FF-961
FF-966
FF-967
FG-941
FH-941
FH-9461
F L-9 41
FL -943
MFS-6-151A-N
MFS-6-153B-N
MFS-6-162B-N
MFS-6-153C-N
MFS-6-162C-N
MFS-7-113C-N
MFS-7-153C-N
MFS-7-163C-N
MFS-8-113B-N
MFS-8-143A-N
MFS-8-153B-N
MFS-8-163B-N
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122A-N
MFS-12E-122A-N
MFS-12-122B-N
MFS-12E-122B-N
MFS-12-122C-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12E-132B-N
MFS-12-132C-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12-144A-N
MFS-12E-143A-N
MFS-13-122A-N
MFS-13-122B-N
MFS-13B-122B-N
MFS-13-122C-N
MFS-13B-122C-N
MFS-13-132B-N
MFS-13-132C-N
MFS-13B-132B-N
MFS-13B-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-14-122A-N
MFS-14-122B-N
MFS-14F-122B-N
MFS-14G-122B-N
MFS-14-122C-N
MFS-14F-122C-N
MFS-14G-122C-N
MFS-14-124A-N
MFS-14-132B-N
MFS-14F-132B-N
MFS-14G-132B-N
MFS-14-132C-N
MFS-14F-132C-N
MFS-14G-132C-N
MFS-14-142B-N
MFS-14F-142B-N
MFS-14G-142B-N
MFS-14-142C-N
MFS-14F-142C-N
MFS-14G-142C-N
MFS-14-143A-N
MFS-14-144A-N
MFS-16-122A-N
MFS-16-133A-N
MFS-16-135A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
1 Can also be used with reduced steer angles in tag position in Coach applications.

GENERAL SERVICE

WARRANTY INFORMATION
Coverage under Cummins-Meritor’s warranty require that
the application of products be properly approved pursuant to OEM and Cummins-Meritor approvals. Refer to TP-9441
for axles, SP-8320 for trailer axles, TP-12126 for drivelines and/or contact Cummins-Meritor regarding specific
application approval questions on any product line.

Page 441 of 519 ends

7 GENERAL SERVICE

WARRANTY INFORMATION
Rear Drive Tandem/Tridem Axles – 2/Unl/P&L
MT-34-14X /P
MT-40-14T/P
MT-40-14X /P
MT-44-14X /P
RT-46-169
MT-52-616
RT-52-1851
MT-58-616
RT-58-1851
MT-70-380
RZ-188
1 Each vehicle must have a Request for Application Recommendation (RAR) approved by Cummins-Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details.

Rear Drive Tandem/Tridem – 3/Unl/P&L
RT-40-160/P RT-46-160/P RT-46-164/P RT-50-160/P RZ-166
Rear Drive Axles – 1/Unl/P&L
RND-14H RND-16A
PTO – 1/Unl/P&L
MPT-170
MPT-180
MPT-185
MPT-309
MPT-500
MPT-518
MPT-1702
Brake Components
Cam Q Series Trailer Brakes1 3/Unl/P, 1/Unl/L
Cam P2 2/200/P
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
Q+ Drum Brake™1,2 2/200/P&L
ASA 3/Unl/P
ASA2 2/200/P
Hubs/Cast Drums and Other Wheel-End Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
STEELite X30 Drum Brake™3 12-Years or Wearable Life/P
EX+ Air Disc Brake™4 2/Unl/P&L
1 For Trailer only, 3/300/P against rust jacking when equipped with Platinum Shield III or Chassis Protect.
2 Applies to Tour Bus and Cross Country Coach only.
3 Based on stamped wear diameter max.
4 Warranty coverage for boots, seals, caps, bushings and pins is 2/200/P.

Warranty coverage for pads is 1/100/P.

Drivelines
RPL 4/400/P , 1/Unl/P&L
MXL 3/350/P , 1/Unl/P&L
92N 1/Unl/P
Rear Drive Single Axles – 2/Unl/P&L
MS-17-13X
MS-17-14X
MS-19-13X
MS-19-14X
MS-21-13X
MS-21-14X
MS-23-17X
RS-21-160
RC-23-160
RC-23-161
RC-23-1621
RC-23-1651
RS-23-160
RS-23-161
RS-23-185
RS-23-186
RS-24-160
RC-25-160
RS-26-185
MS-26-616
MS-26-616-SP
RS-30-185
MS-30-616
MS-30-616-SP
RS-35-380
1 3/Unl/P&L if PreSet by Cummins-Meritor.

Page 442 of 519 ends

8 Trailer Axles1
Beam and Brackets2 5/Unl/P, 1/Unl/L
TPX4000 Axle Series 3 10/Unl/P, 1/Unl/L
Wheel End Systems4
Standard System 5 1/Unl/P&L
AxlePak5 5/Unl/P&L
AxlePak76 7/Unl/P&L
AxlePak107 10/Unl/P&L
1 For brake components and ABS coverage, refer to appropriate product warranties.
2 9000 Series is 3/Unl/P , 1/Unl/L
3 Structural components only excluding spindle wear. Spindle wear 5/Unl/P, 1/Unl/L.
4 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage. 5 When installed by Cummins-Meritor.
6 When specified with AxlePak7 wheel end system, coverage on Meritor Tire Inflation System (MTIS) thru-tee and stator is 7/Unl/P, 1/Unl/L. 7 AxlePak10 is limited to Intermodal Chassis applications equipped with TPX4000 series axles.

TAG/Pusher Axles1
TQ, TR Beam and Brackets 3/Unl/P , 1/Unl/L
MC14002, MC16003, FH946 2 2/Unl/P&L
1 For brake components coverage, refer to appropriate product warranties. 2 3/Unl/P&L if sold with PreSet by Cummins-Meritor.

Meritor Tire Inflation System
(MTIS)
MTIS Components 5/Unl/P , 1/Unl/L
Trailer Mechanical Suspension
Systems1
IMS40 (Integrated Mechanical Suspension – Tandem)2 1/Unl/P&L IMS20 (Integrated Mechanical Suspension – Single)2 1/Unl/P&L 1 For axle coverage, refer to appropriate product warranties. 2 All other suspension components refer to appropriate manufacturer’s warranty.

Trailer Air Suspension Systems1
MPA40 (Tandem Axle Parallelogram)2
Major Structural Components 5/Unl/P, 1/Unl/L
Curbing Damage Warranty3 5/500/P , 1/100/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs 2/Unl/P , 1/Unl/L
Bushings 5/P , 3/L
PinLoc Air Controls 1/Unl/P&L
PinLoc Actuator 3/Unl/P&L
MPA20 (Single Axle Parallelogram)
Major Structural Components 5/Unl/P, 1/Unl/L
Height Control Valve 1/Unl/P&L
Shock Absorbers 2/Unl/P&L
Air Springs and Rebound Straps 2/Unl/P , 1/Unl/L
Bushings 5/P , 3/L
MTA and MTA-Tec6 Trailing Arm Suspension System
Major Structural Components 5/Unl/P, 1/Unl/L
Height Control Valve 1/Unl/P&L
Air Springs 2/Unl/P , 1/Unl/L
Bushings 4 5/Unl/P, 3/Unl/L
Shock Absorbers 2/Unl/P&L
Lift Kit System 1/Unl/P&L
1 For axle coverage, refer to appropriate product warranties. 2 Fastener torque coverage is limited to 2/Unl/P&L when torqued by Cummins- Meritor.
3 “Curbing damage” is defined as deformation (bending, buckling or breakage), caused by sudden impact with a curb or similar fixed object. Damage to the RideSentry slider box (the suspension sliding sub-frame, consisting of the frame rails, cross-members and central A-frame assembly), caused by accidental trailer impact with a curb or similar fixed object, is eligible for warranty coverage. Damage to other components or damage resulting from collision with another vehicle, rollover or fire is not covered under this provision. Warranty is not transferable to another trailer VIN and coverage does not apply if the trailer is deemed to be a total loss, scrapped or otherwise not salvageable. 4 Raw wood applications 3/Unl/P, 1/Unl/L

GENERAL SERVICE

WARRANTY INFORMATION

Page 443 of 519 ends

9 Heavy Service/Specialty Vehicles
Airport Rescue Fire
Fighting (ARFF)
Airport Shuttle1
Asphalt Truck
Block Truck
Bottom Dump Trailer
Combination
Cementing Vehicle
Commercial Pick-Up
Concrete Pumper
Construction Material Hauler
Mixer
Demolition
Drill Rig
Dump
Equipment Hauling
Flatbed Trailer Hauler
Flatbed Truck
Fracturing Truck
Front Loader
Geophysical Exploration
Hopper Trailer Combinations
Landscaping Truck
Liquid Waste Hauler
Log Hauling
Lowboy
Michigan Special Gravel
Train
Michigan Special Log Hauler
Michigan Special Steel
Hauler
Michigan Special Waste
Vehicle
Municipal Dump
Rear Loader (Refuse)
Recycling Truck
Residential Pick-Up (Refuse)
Rigging Truck
Roll-Off
Scrap Truck
Semi-End Dump
Sewer/Septic Vacuum
Shuttle Bus1
Side Loader
Snowplow/Snowblower
Steel Hauling
Tanker
Tank Truck
Tractors with Pole Trailers
Tractor/Trailer with Jeeps
Transfer Dump
Transfer Vehicle
Utility Truck
Winch Truck
1 Commercial chassis only
Heavy Service/Specialty Vehicle
Typically Is:

Moderate mileage operation (less than 60,000 miles per year) On/off-road vocations (10% or more off-road)
Moderate to frequent stops/starts (up to 10 stops per mile) An average of three (3) miles between starting and stopping Front Non-Drive Steer Axles – 2/Unl/P&L
FD-965
FF-941
FF-942
FF-943
FF-944
FF-946
FF-961
FF-966
FF-967
FG-941
FG-943
FH-941
FH-946
F L-9 41
FL -943
MFS-6-151A-N
MFS-6-153B
MFS-6-162B
MFS-6-162C
MFS-7-113C-N
MFS-7-153C-N
MFS-7-163C-N
MFS-8-113B-N
MFS-8-153B-N
MFS-8-163B-N
MFS-10-122A
MFS-10-143A-N
MFS-10-144A-N
MFS-12-122
MFS-12E-122
MFS-12-122B-N
MFS-12E-122B-N
MFS-12-122C-N
MFS-12E-122C-N
MFS-12-124A-N
MFS-12-132B-N
MFS-12E-132B-N
MFS-12-132C-N
MFS-12E-132C-N
MFS-12-143A-N
MFS-12-144A-N
MFS-12-155
MFS-13-122
MFS-13-122B-N
MFS-13B-122B-N
MFS-13-122C-N
MFS-13B-122C-N
MFS-13-132B-N
MFS-13B-132B-N
MFS-13-132C-N
MFS-13B-132C-N
MFS-13-143A-N
MFS-13-144A-N
MFS-13-155
MFS-14-122
MFS-14-122B-N
MFS-14F-122B-N
MFS-14G-122B-N
MFS-14-122C-N
MFS-14F-122C-N
MFS-14G-122C-N
MFS-14-124A-N
MFS-14-132B-N
MFS-14F-132B-N
MFS-14G-132B-N
MFS-14-132C-N
MFS-14F-132C-N
MFS-14G-132C-N
MFS-14-142B-N
MFS-14F-142B-N
MFS-14G-142B-N
MFS-14-142C-N
MFS-14F-142C-N
MFS-14G-142C-N
MFS-14-143A-N
MFS-14-144A-N
MFS-16-122A-N
MFS-16-133A-N
MFS-16-135A-N
MFS-16-143A-N
MFS-18-133A-N
MFS-18-135A-N
MFS-18-192A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
RF-16-145
RF-21-160

HEAVY SERVICE/SPECIALTY VEHICLE

WARRANTY INFORMATION
Coverage under Cummins-Meritor’s warranty require that
the application of products be properly approved pursuant to OEM and Cummins-Meritor approvals. Refer to TP-9441
for axles, SP-8320 for trailer axles, TP-12126 for drivelines and/or contact Cummins-Meritor regarding specific
application approval questions on any product line.

Page 444 of 519 ends

10 Rear Drive Axles – 2/Unl/P&L
MS-17-14X
MS-19-14X
MS-21-14X
RS-21-160
RC-23-160
RH-23-160
RS-23-160
RC-23-161
RS-23-161
RS-23-185
RS-23-186/380
RS-24-160
RC-25-160
RS-25-160
MS-26-616
MS-26-616-SP
RS-26-185/380
RC-26-633
MS-30-616
MS-30-616-SP
RS-30-185/380
MS-35-380
RS-38-380
MT-58-616
MT-58-616-SP
Rear Drive Axles – 1/Unl/P&L
RND-14H RND-16A
Rear Drive Tandem/Tridem Axles – 2/Unl/P&L
MT-34-14X /P
MT-40-14T/P
MT-40-14X /P
MT-44-14X /P
RT-46-169
RT-58-160
MT-52-616
MT-52-616-SP
RT-52-185/3801,2
MT-58-616
MT-58-616-SP
RT-58-185/3801,2
RT-70-380
MT-70-380
RZ-188
1 Axle model designated will vary according to options and variations specified on these axles. Contact Cummins-Meritor Axle Applications Engineering for details. 2 Each vehicle must have a Request for Application Recommendation (RAR) approved by Cummins-Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details.

Rear Drive Tandem/Tridem – 3/Unl/P&L
RT-40-160/P/A3 RT-46-160/P/A1,3 RT-46-164/P2,3 RT-50-160/P/A3 RZ-166 1 U.S. only. Canadian warranty = 1/Unl/P for combination vehicles only. 2 Axle model designated will vary according to options and variations specified on these axles. Contact Cummins-Meritor Axle Applications Engineering for details. 3 Each vehicle must have a Request for Application Recommendation (RAR) approved by Cummins-Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details.

Front Drive Steer Axles – 1/Unl/P&L
MX-08-130-FV (FSD-08A)
MX-10-130-FV (FSD-10A)
MX-12-130-FV (FSD-12A)
MX-13-130-FV (FSD-13A)
MX-14-130-FV (FSD-14A)
MX-16-130-FV (FSD-16A)
MX-18-130-FV (FSD-18A)
MX-18-130-SD (SDA-1800)
MX-20-130-FV (FSD-20A)
MX-21-130-FV (FSD-21A)
MX-21-130-SD (SDA-2100)
MX-23-130-FV (FSD-23A)
MX-23-130-SD (SDA-2300)

HEAVY SERVICE/SPECIALTY VEHICLE

WARRANTY INFORMATION
MX-10-120
MX-10-120 EVO
MX-12-120
MX-12-120 EVO
MX-14-120
MX-14-120 EVO
MX-16-120
MX-18-120
MX-17-140
MX-19-140
MX-21-140
MX-21-160
MX-23-160
MX-23-810
Front Drive Steer Axles – 2/Unl/P&L
MPT-170
MPT-180
MPT-185
MPT-309
MPT-500
MPT-518
MPT-1702
PTO – 1/Unl/P&L

Page 445 of 519 ends

11 Drivelines
RPL 3/Unl/P , 1/Unl/P&L
92N 1/Unl/P&L
MXL 1/Unl/P&L
Transmission – 1/Unl/P&L
FAT 30
Brake Components
Cam P 3/Unl/P
Cam P 2/100/P
Cam Cast Plus™ 2/100/P&L
Q+ Drum Brake™1 3/Unl/P&L
Q+ Drum Brake™2 2/100/P&L
ASA 3/Unl/P
ASA2 2/100/P
Hubs/Cast Drums and Other Wheel-End Components 3 1/Unl/P Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake4 2/100/P&L
1 For Trailer only, 3/300/P against rust jacking when equipped with Platinum Shield III.
2 Applies to City Bus, Trolley, Shuttle Bus and Airport Shuttle only. 3 Based on stamped wear diameter max.
4 Warranty coverage for boots, seals, caps, bushings and pins is 2/100/P.

Warranty coverage for pads is 1/100/P.

Trailer Axles1
Beam and Brackets2 5/Unl/P, 1/Unl/L
Wheel End Systems3
Standard System 4 1/Unl/P&L
1 For brake components coverage, refer to appropriate product warranties. 2 9000 Series is 3/Unl/P , 1/Unl/L
3 Includes hub, wheel seals and wheel bearings—all systems require annual inspections and proper documentation to ensure full coverage. 4 When installed by Cummins-Meritor.

Trailer Air Suspension Systems1
MTA and MTA-Tec6 Trailing Arm Suspension System
Major Structural Components 2 5/500/P , 1/100/L
Height Control Valve 1/100/P&L
Air Springs 2/200/P , 1/100/L
Bushings 2 5/500/P , 3/300/L
Shock Absorbers 2/200/P&L
Lift Kit System 1/100/P&L
1 For axle coverage, refer to appropriate product warranties. 2 Raw wood applications 3/Unl/P, 1/Unl/L
Meritor Tire Inflation System
(MTIS)
MTIS Components 5/Unl/P , 1/Unl/L
Gearboxes – 1/Unl/P&L
MGX-402
MGX-423
MGX-450
MGX-451
MGX-466
MGX-479
MGX-538
Transfer Cases – 1/Unl/P
MTC-2212-CV (306)
MTC-3106-FV (TC-137)
MTC-3111 (T-2111)
MTC-3112-CV (548C)
MTC-3116 (T-2111 through-shaft)
MTC-3118-FV (TC-180 and TC-180-23)
MTC-3118-CV (358)
MTC-3120-FV (TC-143)
MTC-3124 (T-2119)
MTC-3203
MTC-3205-GV (MTC-25/RTC-25)
MTC-3206-FV (TC-237)
MTC-3206-CS (544)
MTC-3208-GV (RTC-50)
MTC-3209-GV (MTC-60/RTC-60)
MTC-3212-CV (315 and 548B)
MTC-3312-FV (TC-270)
MTC-3220-FC (TC-142)
MTC-4206-FV (TC-38)
MTC-4208
MTC-4210
MTC-4213

HEAVY SERVICE/SPECIALTY VEHICLE

WARRANTY INFORMATION

Page 446 of 519 ends

12 Fire and Emergency Vehicles
Aerial Ladder Truck
Aerial Platform
Ambulance
Command Vehicle
Crash Fire Rescue
Pumper
Rapid Intervention
Vehicle (RIV)
Tanker
Fire and Emergency Typically Is:

Lower mileage operations (less than 20,000 miles/year)
Generally, on-road service (less than 10% off-road)
An average of three (3) miles between starting and stopping Front Non-Drive Steer Axles – 5/Unl/P&L
F L-9 41
FL -943
MFS-18-133A-N
MFS-18-135A-N
MFS-18-193A-N
MFS-20-133A-N
MFS-20-135A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
Rear Drive Single Axles – 5/Unl/P&L
RC-23-160
RS-23-160
RS-23-161
RS-23-185
RS-23-186
RS-24-160
RC-25-160
RS-26-185
RS-30-185
RS-35-1851
RS-25-160
1 2/Unl/P&L if PreSet by Cummins-Meritor.

Rear Drive Tandem/Tridem Axles – 5/Unl/P&L
MT-40-14X /P
RT-40-160/P
MT-44-14X /P
RT-46-160/P
RT-46-164/P
RT-46-169
RT-50-160/P
MT-52-616
RT-52-1851
MT-58-616
RT-58-1851
MT-70-3802
1 Each vehicle must have a Request for Application Recommendation (RAR) approved by Cummins-Meritor prior to vehicle build. All RARs must identify the chassis number or VIN. Refer to Product Information Letter #303 and #396 for further details. 2 2/Unl/P&L
Front Drive Steer Axles – 2/Unl/P&L
MX-19-140 MX-21-140 MX-21-160 MX-23-160 MX-23-810

FIRE AND EMERGENCY

WARRANTY INFORMATION
Coverage under Cummins-Meritor’s warranty require
that the application of products be properly approved
pursuant to OEM and Cummins-Meritor approvals.

Refer to TP-9441 for axles, TP-12126 for drivelines
and/or contact Cummins-Meritor regarding specific
application approval questions on any product line.

Transfer Cases – 1/Unl/P
MTC-2212-CV (306)
MTC-3106-FV (TC-137)
MTC-3111 (T-2111 through-shaft)
MTC-3112-CV (548C)
MTC-3118-FV (TC-180 and TC-180-23)
MTC-3118-CV (358)
MTC-3120-FV (TC-143)
MTC-3124 (T-2119)
MTC-3206-FV (TC-237)
MTC-3206-CS (544)
MTC-3208-GV (RTC-50)
MTC-3209-GV (MTC-60/RTC-60)
MTC-3212-CV (315 and 548B)
MTC-3312-FV (TC-270)
MTC-3220-FC (TC-142)
MTC-4206-FV (TC-38)
MTC-4208
MTC-4210
MTC-4213

Page 447 of 519 ends

13 PTO – 1/Unl/P&L
MPT-170
MPT-180
MPT-185
MPT-309
MPT-500
MPT-518
MPT-1702

FIRE AND EMERGENCY

WARRANTY INFORMATION
Brake Components
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
ASA 3/Unl/P
Hubs/Cast Drums and Other Wheel-End Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake™1 2/Unl/P&L
1 Warranty coverage for boots, seals, caps, bushings and pins is 2/200/P.

Warranty coverage for pads is 1/100/P.

Drivelines
RPL 4/400/P , 1/Unl/L
MXL 3/350/P , 1/Unl/L
92N 1/Unl/P

Page 448 of 519 ends

14 Transit Bus Vehicles
Airport Shuttle
City Bus
Commuter Coach
Shuttle Bus
Transit Bus Trolley
Transit Bus Typically Is:

Moderate mileage operation (less than 50,000 miles per year) Moderate to frequent stops/starts (up to 10 stops per mile) Front Non-Drive Steer Axles – 5/300/P&L
FH-946 FH-9411 MFS-12-155 MFS-13-155
1 Commuter coach only – 2/Unl/P&L
Tag Axles – 2/Unl/P&L
Brake Components
Cam Cast Plus™ 2/100/P&L
Q+ Drum Brake™1 2/100/P&L
ASA1 2/100/P
Hubs/Cast Drums and Other Wheel-End Components 1/Unl/P
All Other Brakes 1/Unl/P
EX+ Air Disc Brake2 2/100/P&L
1 Applies to City Bus, Trolley, Shuttle Bus and Airport Shuttle only. 2 Warranty coverage for boots, seals, caps, bushings and pins is 2/100/P.

Warranty coverage for pads is 1/100/P.

Drivelines
RPL 3/Unl/P , 1/Unl/L
92N 1/Unl/P&L
MXL 1/Unl/P&L
1 Commuter coach only – 2/Unl/P&L
Rear Drive Single Axles – 5/300/P&L
RS-23-160
RC-23-161
71163
79163
RC-23-1621
RC-23-1651
RS-21-160
MC-14002 MC-16003 FH-946
Center Non-drive Axles – 5/300/P&L
MC-26000 71063 79063
Gearboxes – 1/Unl/P&L
MGX-450 MGX-451 MGX-538

TRANSIT BUS

WARRANTY INFORMATION
Coverage under Cummins-Meritor’s warranty require
that the application of products be properly approved
pursuant to OEM and Cummins-Meritor approvals.

Refer to TP-9441 for axles, TP-12126 for drivelines
and/or contact Cummins-Meritor regarding specific
application approval questions on any product line.

Page 449 of 519 ends

15 Industrial and Off-Highway Service Vehicles
Load-On/Load-Off
Port Tractor
Rail Yard Spotter
Roll-On/Roll-Off
Stevedoring Tractor
Trailer Spotter
Yard Jockey
All and Rough
Terrain Cranes
Forestry
Material Handling
Specialized Heavy
Haul
Excavator
Compactor
Fertilizer Spreader
Snow Blower
Mining and
Specialized Mining
Rail Car Mover
Loader
Tow Tractor
Pushback Tractor
Industrial and Off-Highway Service Typically Is:

Low mileage operation
Low speed vehicle speed restriction
Vehicles are not typically licensed for highway use
Six (6) starts/stops per mile (typical)
Front Non-Drive Steer Axles – 1/Unl/P
FF - 941
FF - 943
FF - 961
FF - 966
FG - 941
FG - 943
FL - 941
FL - 943
FN - 951
FS-25
MFS-20-133A-N
MFS-20-135A-N
MFS-20-192A-N
MFS-20-193A-N
MFS-22-135A-N
MFS-22H-135A-N
MFS-22-193A-N
MFS-22H-193A-N
MON-Z0 FAMILY
Gearboxes – 1/Unl/P&L
MGX-402
MGX-423
MGX-450
MGX-451
MGX-466
MGX-479
MGX-538
PTO – 1/Unl/P&L
MPT-170
MPT-180
MPT-185
MPT-309
MPT-500
MPT-518
MPT-1702
1 2/Unl/P for LO/LO Terminal Tractor applications
Planetary Axles – 1/Unl/P
MOB
MOC
MOD
MOE
MOF
MOG
MOH
MOR
MOS
MOT
MOX
MOY
MOZ
Rear Drive Axles – 1/Unl/P
MT-14X1
RS-23-186
RS-23-380
RS-24-160
RS-30-185
RS-30-380
RT-1451
RT-1601

OFF-HIGHWAY SERVICE

WARRANTY INFORMATION
Coverage under Cummins-Meritor’s warranty require that the application of products be properly approved pursuant to OEM and Cummins-Meritor approvals. Contact Cummins-Meritor regarding specific application approval questions on any product line.

Page 450 of 519 ends

16 Drivelines – 1/Unl/P

RPL MXL
Transmission – 1/Unl/P&L
FAT 30
Brake Components
Cam 3/Unl/P
Q+ Drum Brake™ 3/Unl/P&L
ASA 3/Unl/P
Hubs/Cast Drums and Other Wheel-End Components 1/Unl/P
Hydraulic Disc Brakes 1/Unl/P
All Other Brakes 1/Unl/P

OFF-HIGHWAY SERVICE

WARRANTY INFORMATION
Transfer Cases – 1/Unl/P
MTC-2212-CV (306)
MTC-3106-FV (TC-137)
MTC-3111 (T-2111 through-shaft)
MTC-3112-CV (548C)
MTC-3116 (T-2111)
MTC-3118-FV (TC-180 and TC-180-23)
MTC-3118-CV (358)
MTC-3120-FV (TC-143)
MTC-3124 (T-2119)
MTC-3206-FV (TC-237)
MTC-3208-GV (RTC-50)
MTC-3209-GV (MTC-60/RTC-60)
MTC-3220-FC (TC-142)

Page 451 of 519 ends

17 Coverage Exclusions
Product Description
All
The cost of any repairs, replacements or adjustments to a covered component (1) associated with noise; (2) resulting from the use or installation of non-genuine Cummins-Meritor components or materials; (3) due to vibration associated with improper operation or misapplication of drivetrain components; and (4) damage resulting from corrosion.

For axle assemblies supplied by Cummins-Meritor with suspension and interface brackets designed and/or attached by non- Cummins-Meritor parties, Cummins-Meritor warranty coverage does not apply to the brackets, bracket attachment methods and field issues caused by brackets or bracket attachments to any covered component unless specified in a separate OEM agreement.

Front Axles1
Linehaul – King Pin Bushings 1yr/Unl P&L
All Other Vocations – King Pin Bushings Excluded
1 King Pin Bushing wear excluded for all vocations.

Rear Axles
Self-contained traction equalizers and oil filters. The use of NoSPIN differentials will result in the exclusion of axle shafts from warranty considerations. NoSPIN is a product of Eaton.

ASA
Boot and bushing. Bent, broken, over-torqued, missing or otherwise damaged pawl assemblies.

Cam Brake
Brake lining wear and brake shoe “rust-jacking.”
Disc Brake
Pad wear, rotor wear.

Coverage Limitations
Product Description
All
Any claim beyond 60 days from date of repair will not be accepted or honored under this warranty program. Products purchased on an incomplete vehicle (glider) are limited to one year, unlimited miles parts only (1/Unl/P).

Warranty coverage on vehicles with 1,850 lb-ft engine torque and over may be reduced on individual drivetrain components. Contact your Cummins-Meritor representative for specific details.

Front Axles
Tie rod and tie rod ends limited to 3-year/300,000-mile or published vocational coverage, whichever is less. Wheel seals, gaskets and wheel bearings are covered for 1 year/unlimited miles if the wheel end equipment is supplied and assembled by Cummins-Meritor.

Rear Axles
Pinion and through shaft seals limited to 3-year/300,000-mile or published vocational coverage, whichever is less, if yoke is installed by Cummins-Meritor. If yoke is not installed by Cummins- Meritor, then Cummins-Meritor does not warrant pinion seals.

Wheel seals, gaskets and wheel bearings are covered for 1 year/unlimited miles if the wheel end equipment is supplied and assembled by Cummins-Meritor.

Rear Axles
The Cummins-Meritor breather part number A-2297-C-8765 with A-3196-J-1336 hose must be used for eligibility of any potential warranty consideration relating to contamination and/or loss of lube in axles.

Cam Brake
Limited to bracket, brake spider and camshaft structural integrity.

STEELite X30
Wearable life is up to the discard diameter of the drum.

Terms and Conditions
(1) What is Covered by this Commercial Warranty?
Meritor Heavy Vehicle Systems, LLC warrants to the owner (“Owner”) that the components listed in this publication, which have been installed by an Original Equipment Manufacturer (“OEM”) as original equipment in vehicles licensed for on-highway use, will be free from defects in material and workmanship. This warranty coverage begins only after the expiration of the OEM’s vehicle warranty for the applicable covered components. Warranty coverage ends at the expiration of the applicable time period from the date of vehicle purchase by the first Owner or the applicable mileage limitation, whichever occurs first. Duration of coverage varies by component and vocation as detailed elsewhere in this warranty statement.

Some components are warranted for parts only and the Owner must pay any labor costs associated with the repair or replacement of the component.

Other components are warranted for both parts and reasonable labor to repair or replace the subject component. Components (whether new, used or remanufactured) installed as replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty.

For certain components, coverage requires the use of specific extended drain interval or synthetic lubricants. For further information about lubrication and maintenance, see Cummins-Meritor publication Maintenance Manual Number l and the applicable Cummins-Meritor maintenance manual for the product in question. Other conditions and limitations applicable to this warranty are detailed below.

TERMS AND CONDITIONS

Page 452 of 519 ends

Product models, brands, names and trademarks depicted herein are the property of their respective owners and, except where otherwise indicated, are not in any way associated with Meritor Heavy Vehicle Systems, LLC, or any parent or affiliate, thereof. (2) Designation of Vocational Use Required
To obtain warranty coverage, each Owner must notify Cummins-Meritor through the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the Cummins-Meritor components have been incorporated prior to the vehicle in-service date. This notification may be accomplished by registering the vehicle through your OEM new truck and/or trailer dealer or with Cummins-Meritor directly. Failure to notify Cummins- Meritor of (I) the intended vocational use of the vehicle or (II) a change in vocational use from that which was originally designated, will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial in-service date.

A second Owner and each subsequent Owner must also notify Cummins- Meritor as to the intended vocational use of the vehicle. This notification can be sent directly to Cummins-Meritor or through the OEM new truck and/ or trailer dealer. The duration and mileage coverage of this warranty cannot exceed the coverage extended to the first Owner after his or her initial designation of vocational use.

Coverage under Cummins-Meritor’s warranty requires that the application of products be properly approved pursuant to OEM and Cummins-Meritor approvals. Refer to TP-9441 for axles, SP-8320 for trailer axles, TP-12126 for drivelines and/or contact Cummins-Meritor regarding specific application approval questions on any product line.
(3) What is the Cost of this Warranty?
There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty?
This warranty does not cover normal wear and tear; nor does it cover a component that fails, malfunctions or is damaged as a result of (I) improper installation, adjustment, repair or modification (including the use of unauthorized attachments or changes or modification in the vehicle’s configuration, usage or vocation from that which was originally approved by Cummins-Meritor), (II) accident, natural disaster, abuse or improper use (including loading beyond the specified maximum vehicle weight or altering engine power settings to exceed the axle and/or driveline capacity) or (III) improper or insufficient maintenance (including deviation from approved lubricants, change intervals or lube levels). This warranty does not cover any component or part that is not branded by Cummins-Meritor. For vehicles that operate full or part time outside of the United States and Canada, a one year, unlimited mileage, parts only warranty (1/Unl/P) will apply.
(5) Remedy
The exclusive remedy under this warranty shall be the repair or replacement of the defective component at Cummins-Meritor’s option. Cummins-Meritor reserves the right to require that all applicable failed materials are available and/or returned to Cummins-Meritor for review and evaluation. (6) Disclaimer of Warranty

THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES

OR CONDITIONS, EXPRESSED, IMPLIED OR STATUTORY INCLUDING

ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR
PARTICULAR PURPOSE.
(7) Limitation of Remedies
In no event shall Cummins-Meritor be liable for special, incidental, indirect or consequential damages of any kind or under any legal theory, including, but not limited to, towing, downtime, lost productivity, cargo damage, taxes or any other losses or costs resulting from a defective covered component. (8) To Obtain Service
If the Owner discovers within the applicable coverage period a defect in material or workmanship, the Owner must promptly give notice to either Cummins-Meritor or the dealer from which the vehicle was purchased. To obtain service, the vehicle must be taken to any participating OEM new truck and/or trailer dealer or authorized Cummins-Meritor service location. The dealer will inspect the vehicle and contact Cummins-Meritor for an evaluation of the claim. When authorized by Cummins-Meritor, the dealer will repair or replace during the term of this warranty any defective Cummins-Meritor component covered by this warranty.
(9) Entire Agreement
This is the entire agreement between Cummins-Meritor and the Owner about warranty and no Cummins-Meritor employee or dealer is authorized to make any additional warranty on behalf of Cummins-Meritor. This agreement allocates the responsibilities for component failure between Cummins-Meritor and the Owner.

TERMS AND CONDITIONS
Cummins Inc.

Box 3005
Columbus, IN 47202-3005
U.S.A.
cummins.com
SP-95155
Bulletin 6451105 Produced in U.S.A. Rev. 1/24
©2024 Meritor, Inc.

Page 453 of 519 ends

)LUHDQG5HVFXH$SSDUDWXV
Coverage:
7KUHH

<HDU0DWHULDODQG:RUNPDQVKLS
0HULWRU:DEFR$%6%UDNH6\VWHP
Limited Warranty
Notwithstanding anything to the contrary herein, Pierce makes no warranty whatsoever as to:

The Meritor Wabco ABS brake system shall be covered by
Meritor Wabco as indicated in the attached Meritor Wabco warranty coverage description
/,0,7(':$55$17<
(b) any vehicle, chassis, or component, part, attachment or accessory damaged by misuse, neglect, fire, exposure to severe environmental or chemical conditions, acidic environment, improper maintenance, accident, crash, or force majeure such as natural disaster, lightning, earthquake, windstorm, hail, flood, war or riot; Subject to the limitations and exclusions set forth below, Pierce Manufacturing provides the following warranty to the Buyer:
(c) any vehicle, chassis or component, part, attachment or accessory that has been repaired, altered or assembled in any way by any person or entity other than Pierce which, in the sole judgment of Pierce, adversely affects the performance, stability or purpose for which it was manufactured; or
(a) any integral parts, components, attachments or trade accessories of or to the product that are not manufactured by Pierce, including but not limited to engines, transmissions, drivelines, axles, water pumps and generators; with respect to all such parts, components, attachments and accessories, Pierce shall assign to Buyer the applicable warranties, if any, made by the respective manufacturers thereof; The date of the original purchase invoice (issued when the product ships from the factory).Warranty Begins:
(d) products or parts which may in the ordinary course wear out and have to be replaced during the warranty period, including, but not limited to, tires, fluids, gaskets and light bulbs. Pierce assumes no responsibility for the assembly of its parts or subassemblies into finishing products or vehicles unless the assembly is performed by Pierce.

Three (3) YearWarranty Period
Ends After:

The original purchaser may void this warranty in part or in its entirety if the product is repaired or replaced (a) without prior written approval of the Pierce Customer Service Department; or (b) at a facility which has not been approved by Pierce as to technical This limited warranty shall apply only if the product is properly maintained in accordance with Pierce's maintenance instructions and manuals and is used in service which is normal to the particular model. Normal service means service which does not subject the product to stresses or impacts greater than normally result from careful use. If the Buyer discovers a defect or nonconformity, it must notify Pierce in writing within thirty (30) days after the date of discovery, but in any event prior to the expiration of the warranty period.

THIS LIMITED WARRANTY MAY NOT BE ASSIGNED OR OTHERWISE

TRANSFERRED BY THE BUYER TO ANY SUBSEQUENT USER OR PURCHASER OR TO ANY OTHER PERSON OR ENTITY.

The exclusions listed in the attached Meritor Wabco warranty description shall apply.

Conditions and
Exclusions:

See Also
Paragraphs
2 thru 4
(;&/86,212)&216(48(17,$/$1',1&,'(17$/'$0$*(6
Notwithstanding anything to the contrary herein or in any agreement between Pierce and Buyer, IN NO EVENT SHALL PIERCE BE LIABLE FOR ANY CONSEQUENTIAL,

INCIDENTAL, SPECIAL, INDIRECT, OR PUNITIVE DAMAGES WHATSOEVER,

WHETHER ARISING OUT OF BREACH OF CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE AND STRICT LIABILITY) OR OTHER THEORY OF LAW

OR EQUITY, WITH RESPECT TO VEHICLES OR OTHER PRODUCTS SOLD BY

PIERCE, OR THEIR OPERATION OR FAILURE TO OPERATE, OR ANY DEFECTS

THEREIN, OR ANY UNDERTAKINGS, ACTS OR OMISSIONS RELATED THERETO,

REGARDLESS OF WHETHER PIERCE HAS BEEN INFORMED OF THE
POSSIBILITY OF ANY SUCH DAMAGES. Without limiting the generality of the foregoing, Pierce specifically disclaims any liability for property or personal injury damages, penalties, damages for lost profits or revenues, loss of vehicles or products or any associated equipment, cost of substitute vehicles or products, down-time, delay damages, any other types of economic loss, or for any claims by any third party for any such damages.

If the product fails to conform to the warranty set forth in paragraph 1 during the warranty period, and such nonconformity is not due to misuse, neglect, accident or improper maintenance, Buyer must notify Pierce within the time period specified in paragraph 1, and shall make the product available for inspection by Pierce or its designated agent. At the request of Pierce, any allegedly defective product shall be returned to Pierce by Buyer for examination and/or repair. Buyer shall be responsible for the cost of such transportation, and for risk of loss of or damage to the product during transportation.

Within a reasonable time, Pierce shall repair or replace (at Pierce's option and expense) any nonconforming or defective parts. Repair or replacement shall be made only by a facility approved in advance in writing by Pierce. THIS REMEDY SHALL BE THE EXCLUSIVE AND SOLE REMEDY FOR ANY BREACH OF WARRANTY.
%8<(5
6(;&/86,9(5(0('<
Note: Any Surety Bond, if a part of the sale of the vehicle as to which this limited warranty is provided, applies only to this Pierce Basic One Year Limited Warranty for such vehicle, and not to other warranties made by Pierce in a separate document (if any) or to the warranties (if any) made by any manufacturer (other than Pierce) of any part, component, attachment or accessory that is incorporated into or attached to the vehicle.
2/25/2013 WA0232
THE WARRANTY SET FORTH IN PARAGRAPH 1 IS THE SOLE AND EXCLUSIVE WARRANTY GIVEN BY PIERCE. PIERCE HEREBY DISCLAIMS AND EXCLUDES

ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED OR STATUTORY,

INCLUDING WITHOUT LIMITATION ANY WARRANTY OF MERCHANTABILITY, ANY

WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR USAGE OF TRADE.
',6&/$,0(562):$55$17,(6
capability. Any repairs, modifications, alterations or aftermarket parts added after manufacture without the authorization of Pierce may void this warranty.

Page 454 of 519 ends

WARRANTY
Warranty coverage is essential to protecting your investment. But understanding the full details of your coverage can be challenging. This straightforward approach allows you, our valued customer, to better understand how your specific vehicle applications will be covered in your region. Our component warranty coverage is provided according to vocation/usage categories listed below. • Linehaul covers high mileage operation (over 60,000 miles/year) on well-maintained major highways of concrete or asphalt construction.
• General Service covers moderate mileage operations (less than 60,000 miles/year) on well-maintained public roads (less than 10 percent off-road) typically with less than three (3) stops per mile. • Heavy Service (Vocational) covers vehicles with more than 10 percent off-road OR moderate to frequent starts/stops typically with more than three (3) stops per mile.
• Off-Highway Service covers lower mileage operations. Vehicles are not typically licensed for highway use. • The standard aftermarket warranty for WABCO products - including WABCO Original parts, WABCO Reman Solutions, ProVia quality aftermarket parts and WABCO retrofit solutions - is one year, parts only from in-service date when purchased from ZF distributor networks or its affiliates and/or subsidiaries.

MODEL YEAR 2021 VEHICLES
How to Read Warranty Coverage (Example)
Number of Years Mileage (in thousands) Unl=Unlimited P=Parts Only P&L=Parts & Labor 3 300 P

Page 455 of 519 ends

WARRANTY - MODEL YEAR 2021 VEHICLES
¹ ZF and WABCO branded components.
2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve.
• Aerial Ladder Truck
• Aerial Platform
• Ambulance
• Auto Hauler
• Beverage Truck
• Bulk Hauler
• Chip Hauler (Truck)
• Cross Country Coach
• Doubles
• Flatbed
• Front Engine Commercial
Chassis
• Front Engine Integral
Coach
• General Freight
• Grain Hauler
• Intercity Coach
• Intermodal Chassis
• Livestock Hauler
• Meat Packer
• Moving Van
• Municipal Truck
• Pipe Hauler
• Platform Auto Hauler
• Pumper
• Rear Engine Integral Coach
• Recreational Vehicles
• Refrigerated Freight
• School Bus
• Stake Truck
• Tanker
• Tanker Truck
• Triples
• Tour Bus
• Wrecker

LINEHAUL/GENERAL SERVICE VEHICLES

LINEHAUL/GENERAL SERVICE WARRANTY INFORMATION

LINEHAUL TYPICALLY IS
• High mileage operation (over 60,000 miles/year)
• Well maintained major highways of concrete or
asphalt construction

GENERAL SERVICE TYPICALLY IS
• Moderate mileage operations (less than 60,000 miles/year) • Well maintained public roads (less than 10% off-road) • Less than three (3) stops per mile
WABCO Components1
Air Management
Air Brake Valves
1/100/P&LTrailer Lift Axle Control Valve
Trailer Control Line Filter3
Air Compressors (ALL)2 2/200/P&L
Air Dryers (ALL) 3/300/P&L
Aerodynamics
OptiFlow® TrailerSkirt 2/UnU/P
OptiFlow® Trailer Tail and AutoTail 2/UnI/P
Braking Systems
ABS (Anti-Lock Braking System) Air
3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic
Electronic Braking System (EBS)
Electronic Stability Control (ESC)
Roll Stability Control (RSS)
Trailer Roll Stability Support (RSS)
Trailer ABS (Anti-Lock Braking System)
3 Driveline Suspension Control
Clutch Controls 2/200/P&L
Leveling Valves
1/100/P&L
OptiRide® Automated Manual Transmission (AMT)
OptiRide® Electronically Controlled Air Suspension
(ECAS) 3/300/P&L
WABCO Components1 (cont.)
Safety
OnGuardACTIVE®
3/300/P&L
OnLane®
OnLaneALERT®
OnSide®
Trailer SafeStart™
Trailer TailGUARD™
Telematics
TrailerCAST™ Telematics Device 3/300/P&L
Wheel End Solutions
EasyFit™ Slack Adjuster 6/600/P
MAXXUS™ Truck Air Disc Brake 5/500/P&L
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 17 and 19 Air Disc Brake 2/Unl/P and
1/Unl/L
Pan 22 Air Disc Brake 5/500/P and 1/L
TRISTOP™ D Actuator w/ IBV or IRB 6/600/P
TRISTOP™ D Actuator 3/300/P
UNISTOP™ Actuator 2/200/P
Trailer MAXX22T™ Air Disc Brake 5/500/P and 1/L

Page 456 of 519 ends

1 ZF and WABCO branded components. 2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 An extended warranty of 4/400/P will apply when a WABCO Trailer Control Line Filter is used in combination with a WABCO Trailer ABS valve.

WABCO Components1
Air Management
Air Brake Valves
1/100/P&L
Air Compressors (ALL)2
Air Dryers (ALL)
Trailer Control Line Filter3
Braking Systems
ABS (Anti-Lock Braking System) Air 3/300/P&L
ABS (Anti-Lock Braking System) Hydraulic 2/200/P&L
Electronic Braking System (EBS)
3/300/P&L
Electronic Stability Control (ESC)
Trailer ABS Valve3
Roll Stability Control (RSS)
Trailer Roll Stability Support (RSS)
Driveline Suspension Control
OptiRide® Electronically Controlled Air Suspension
(ECAS) 2/200/P&L
Leveling Valves 1/100/P&L
Clutch Controls 2/200/P&L
Safety
OnGuardACTIVE®
3/300/P&L
OnLane®
OnLaneALERT®
OnSide®
Trailer SafeStart™
Trailer TailGUARD™
Telematics
TrailerCAST™ Telematics Device 3/300/P&L
Wheel End Solutions
EasyFit™ Slack Adjuster 2/200/P
MAXXUS™ Air Disc Brake 1/Unl/P&L
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 22, 19 and 17 Air Disc Brake 1/Unl/P&L
Trailer MAXX22T™ 1/Unl/P&L
TRISTOP™ D Actuator w/ IBV 3/Unl/P
TRISTOP™ D Actuator 2/200/P
UNISTOP™ Actuator 1/100/P
• Airport Rescue Fire (ARF)
• Airport Shuttle
• Asphalt Truck
• Block Truck
• Bottom Dump Trailer
Combination
• Cementing Vehicle
• City Bus
• Commercial Pick-Up
• Concrete Pumper
• Construction Material Hauler
• Crash Fire Rescue (CFR)
• Mixer
• Demolition
• Drill Rig
• Dump
• Emergency Service
• Equipment Hauling
• Flatbed Trailer Hauler
• Flatbed Truck
• Fracturing Truck
• Front Loader
• Geophysical Exploration
• Hopper Trailer Combinations
• Landscaping Truck
• Liquid Waste Hauler
• Log Hauling
• Lowboy
• Michigan Special
Gravel Trains
• Michigan Special
Log Hauler
• Michigan Special
Steel Hauler
• Michigan Special
Waste Vehicle
• Municipal Dump
• Newspaper Delivery
• Package Delivery
• Pick-up and Delivery
• Rapid Intervention
Vehicle (RIV)
• Rear Loader
• Recycling Truck
• Residential Pick-Up/Waste
• Rigging Truck
• Roll-Off
• Scrap Truck
• Semi-End Dump
• Sewer/Septic Vacuum
• Shuttle Bus
• Side Loader
• Snowplow/Snowblower
• Steel Hauling
• Tanker
• Tank Truck
• Tractors with Pole Trailers
• Tractor/Trailer with Jeeps
• Transfer Dump
• Transfer Vehicle
• Transit Bus
• Trolley
• Utility Truck
• Winch Truck

HEAVY SERVICE VEHICLES

HEAVY SERVICE (VOCATIONAL) WARRANTY INFORMATION

HEAVY SERVICE TYPICALLY IS
• On/Off road vocations (10% or more off-road) OR
• Moderate to frequent starts/stops typically more than three (3) stops per mile

Page 457 of 519 ends

WARRANTY - MODEL YEAR 2021 VEHICLES

INDUSTRIAL AND OFF-HIGHWAY SERVICE

TYPICALLY IS
• Low mileage operation3
• Vehicles are not typically licensed for highway use
¹ ZF and WABCO branded components. 2 WABCO compressors installed on Cummins, Mercedes, and DDC engines are not warranted or serviced by ZF. Please contact your respective dealer/distributor of those engines for warranty and servicing. 3 Equivalent hours of service limit: 2,000 hours for all components.

INDUSTRIAL/OFF-HIGHWAY SERVICE WARRANTY INFORMATION
WABCO Components1
Air Management
Air Brake Valves
2/Unl/PAir Compressors (ALL)2
Air Dryers (ALL)
Brake Actuation
Air/Hydraulic Actuators
2/Unl/P
Master Cylinders
Remote Actuators
Slave and Wheel Cylinders
Two Fluid Actuators
Brake Locks
Brake Locks (ALL)
2/Unl/PElectric Brake Locks
Lever Locks
Braking Systems
ABS (Anti-Lock Braking System) Air
1/100/P&L
ABS (Anti-Lock Braking System) Hydraulic
Driveline Suspension Control
Clutch Controls
1/100/P&L
Leveling Valves
Electrohydraulics & Controls
Electronic Pedals
2/Unl/PElectrohydraulic Brake Valves (EBV)
Pressure Switches
Hydraulic Braking Solutions
Accumulator Charging Valves
2/Unl/PHydraulic Throttle Controls and Switches
Modulating Brake Valves
Wheel End Solutions
EasyFit™ Slack Adjuster 2/200/P
Caliper Disc Brakes 2/Unl/P
MAXXUS™ Air Disc Brake 1/Unl/P&L
Multiple Disc Brakes 2/Unl/P
IVTM - Wheel Module 6/P
IVTM - All Other Products 2/P
Pan 22, 19 and 17 Air Disc Brake 1/Unl/P&L
TRISTOP™ D Actuator w/ IBV 3/Unl/P
TRISTOP™ D Actuator 2/200/P
UNISTOP™ Actuator 1/100/P
Market Common Application Types
Agriculture
Fertilizer Spreader, Tractor, Heavy Duty Ag
Trailers, Harvester, Sprayer, Skid Loader, Silage
Bagger, Slurry Wagons, Grain Cart
Airport Support
Pushback Tractor, Towing Tugs, Aircraft Tow
Tractor, Refueling Trucks, Food Service Trucks,
Baggage Tractors, De-Icing Equipment,
Runway Clearing Equipment
Construction
All-Terrain Crane, Rough Terrain Crane,
Excavator, Compactor, Wheel Loader, Road
Roller, Motor Grader, Articulated Dump Truck,
Rubber Tire Road Roller, Backhoe Loaders,
Haul Trucks, Scraper Rough Terrain Forklifts,
Trenchers, Drills
Forestry Logging Forwarder, Kidder, Loaders, Yard
Forklifts, Harvesters Fellers
Material Handling
Port Tractor, Rail Yard Spotter, Stevedoring
Tractor, Trailer Spotter, Yard Jockey, Scissor
Lift, Straddle Carrier, Manlift, Forklift, Boom Lift
Telebandlers, Aerial Work Platforms
Mining
Specialized Mining, Excavator, Haul Truck,
Underground Loader, Service Trucks, Wheel
Loaders, Scrapers, Load Haul Dumps,
Personnel Transports, Bolters, Scalers
Municipal
Street Sweeper, Utility Tractor, Utility Trucks,
Tree Trimmers, Dump Trucks, Tow Trucks, Flat
Bed Trucks, Winch Applications
Oil & Gas
Fracturing Trailer, Injecter Heads, Top Drives,
Jack/Lift Boats, Wireline Trucks, Load-On /
Load-Off
Rail
Railcar Mover, Track Layers, Grinders, Platform
Crane, Locomotive Railcars, Ballast Equipment,
Winch Applications

Page 458 of 519 ends

ABS, ELECTRONIC STABILITY CONTROL (ESC),
ROLL STABILITY CONTROL (RSC), OPTIRIDE®,
ONGUARD® AND ONLANE®, COLLECTIVELY
“ELECTRONICS”
Failure of electronic components due to overvoltage
condition, improper grounding, electrostatic discharge
(ESD), improper shielding, electromagnetic interference (EMI), or other wiring or installation issues. Malfunctions and failure codes caused by other electronic subsystem failures (data bus, engine, transmission, dashboard, etc.)

HYDRAULIC COMPONENTS
For certain components, brake fluid DOT3 or DOT4 is
used as the operating medium. Use of any other fluid will void all warranties associated with that component. For hydraulic braking applications the brake fluid is considered a maintenance item. Maintenance intervals are listed in TB- 1367.

COVERAGE LIMITATIONS

PRODUCT DESCRIPTION

ALL PRODUCTS
Any claim beyond 60 days from date of repair will not be accepted or honored under this warranty program.

Products purchased on an incomplete vehicle (glider) are limited to one year, 1/Unl/P .

For vehicles that operate full- or part-time outside of the United States and Canada, a 1-Year/Unlimited Miles parts only (1/Unl/P) will apply.

TOOLBOX PLUS™ DIAGNOSTIC SOFTWARE
Proper diagnostics of WABCO Electronics may require the latest version of TOOLBOX PLUS™. Additional labor due
to use of an outdated version of TOOLBOX™ software
and/or the time to purchase or install the latest version of TOOLBOX PLUS™ are not covered under product
warranty.

TERMS AND CONDITIONS

COVERAGE EXCLUSIONS

PRODUCT DESCRIPTION

ALL PRODUCTS
This Warranty shall not apply to the following, but not limited to: (1) damage to the product or its component
parts caused by incorrect use, installation, maintenance or repair, including without limitation (a) improper fit of mating components or brackets, damaged threads, cut, broken,
chafed, pinched or otherwise damaged wiring (sensors,
harnesses and connectors), (b) sensors damaged during
removal when seized in block, or associated with sensor adjustments/ alignments, and (c) damage resulting from the use or installation of non-genuine WABCO components or
materials; (2) damage to the product, its component parts, or diminished product or component part performance due to incorrect operation, deviation from approved conditions or misapplication; (3) any unauthorized disassembly of the product or its component parts including without limitation (a) obliterated, defaced or missing WABCO or WABCO
name plate, serial numbers or label identifying the device as
a ZF product or WABCO component, (b) changes to sealed
adjusting screws, and (c) opening or attempted repair of non-serviceable components; (4) malfunction
of the component d ue to internal cont amination of t he vehicle system including without limitation (a) water and other contamination damage that is due to the use of a
non-genuine air dryer cartridge or (b) valve failures due to contamination in air system, (5) complaints associated
with noise, (6) damage resulting from corrosion (including oxidation of electrical devices and connections).

AIR DRYERS
Mounting brackets (see vehicle OEM). Desiccant cartridge housing only.

AIR SYSTEM COMPONENTS
Normal wear items; Gladhand seals, dash valve knobs,
valve actuation handles, treadles, pedals.

Page 459 of 519 ends

WARRANTY - MODEL YEAR 2021 VEHICLES
(1) What is Covered by this Commercial Warranty?
ZF CV Systems North America LLC and its North American
subsidiaries and affiliates (ZF) warrant to the owner (“Owner”) that the components listed in this publication, which have been installed by an Original Equipment Manufacturer (“OEM”) as original equipment will be free from defects in material and workmanship. This warranty coverage begins from the original in-service date to the limits provided and runs concurrently with any warranties provided by OEMs and/or any distribution agreements and/or any service contracts that cover the components listed in this publication, if any. If the components listed in this publication are covered by an OEM warranty and/or service contract, then the OEM’s warranty and/ or service contract shall supersede ZF’s warranty and Owner shall comply with all OEM’s warranty and/or service contract requirements for claims under such OEM’s warranty and/or service contract until those agreements expire.

Once those agreements expire and provided the ZF warranty has not expired under the terms stated above, the ZF warranty will be in effect until its expiration date.

Warranty coverage ends at the expiration of the applicable time period from the date of vehicle purchase by the first Owner, or, the applicable mileage limitation, whichever occurs first. Duration of coverage varies by component and vocation as detailed previously in this publication.

Some components are warranted for parts only and the Owner must pay any labor costs associated with the repair or replacement of the component. Other components are warranted for both parts and reasonable labor to repair or replace the subject component.

Additional diagnostic time due to use of an outdated version of TOOLBOX™, time to purchase or install latest version of TOOLBOX™ are the responsibility of the authorized ZF distributor networks and are not covered under product warranty. Components installed as replacements under this warranty are warranted only for the remainder of the original period of time or mileage under the original warranty. (2) Designation of Vocational Use Required. To obtain warranty coverage, each Owner must notify ZF through the OEM new truck and/or trailer dealer of the intended vocational use of the vehicle into which the WABCO components have been incorporated prior to the vehicle in- service date. This notification may be accomplished by registering the vehicle through your OEM new truck and/or trailer dealer or with ZF directly. Failure to notify ZF of (I) the intended vocational use of the vehicle or (II) a change in vocational use from that which was originally designated, will result in the application of a one year, unlimited mileage, parts only warranty (1/Unl/P) from the initial in- service date. A second Owner and each subsequent Owner
must
also notify ZF as to the intended vocational use of the vehicle. This notification can be sent directly to ZF or through
the OEM new truck and/or trailer dealer. The duration and mileage coverage of this warranty cannot exceed the coverage extended to the first Owner after his or her initial designation of vocational use. Coverage under ZF’
s warranty requires that the application of
products be properly approved pursuant to OEM and ZF, approvals. (3) What is the Cost of this Warranty? There is no charge to the Owner for this warranty.
(4) What is not Covered by this Warranty? In addition to the items listed on "Coverage Exclusions," this warranty does not cover normal wear and tear, or service items; nor does it cover a component that fails, malfunctions or is damaged as a result of (a) improper handling, storage, installation, adjustment, repair or modification including the use of unauthorized attachments or changes or modification in the vehicle’s configuration, usage, or vocation from that which was originally approved by ZF, (b) accident, fire or other casualty, natural disaster, road debris, negligence, misuse, abuse, or improper use (including loading beyond the specified maximum vehicle weight or altering engine power settings to exceed the brake system capacity),
or (c) improper or insufficient maintenance (including deviation from maintenance intervals, approved lubricants, or lube levels). This warranty does not cover any component or part that is not sold by ZF. (5) To obtain service. If the owner discovers within the applicable coverage period a defect in material or workmanship, the Owner must promptly give notice to either ZF or the dealer from which the vehicle was purchased. To obtain service, the vehicle must be taken to any participating OEM dealer or ZF distributor networks' servicer. The dealer or ZF authorized servicer will inspect the vehicle and contact ZF for an evaluation of the claim. When authorized by ZF, the dealer or ZF authorized servicer will repair or replace during the term of this warranty any defective WABCO component covered by this warranty. (6) Disclaimer of Warranty and Limitation of remedies. TO THE MAXIMUM

EXTENT PERMITTED BY LAW, THE LIMITED WARRANTY SET

FORTH HEREIN IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER

WARRANTIES, EXPRESS OR IMPLIED, ARISING BY OPERATION OF

LAW OR OTHERWISE, INCLUDING, WITHOUT LIMITATION, ANY

IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A

PARTICULAR PURPOSE AND/OR WARRANTY FOR HIDDEN OR

LATENT DEFECTS, AND IN NO EVENT WILL ZF OR ANY OF ITS

AFFILIATES BE LIABLE FOR DIRECT, INDIRECT, INCIDENTAL,

PROGRESSIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES OF ANY
KIND.

TERMS AND CONDITIONS

Page 460 of 519 ends