GOHEEN CIR.
127
PROJECT NO.

LAST SAVED BY:

FILE NAME:

Plot Date:

NKM
AL
DGB
G05
5 GENERAL

SURVEY CONTROL AND GEOTECHNICAL BORINGS
201631G05.dwg
TDonnell
201631-100000
9/12/2022 7:29:07 AM

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
80'40'0 20'
SCALE: 1" = 40'
SURVEY CONTROL:

SKYVIEW
RESERVOIR 1

GOHEEN CIR
SEE SECTION 01722 FOR CONTRACTOR'S REQUIREMENTS FOR SURVEY CONTROL.

BASIS OF BEARINGS AND COORDINATES:

THE COORDINATE SYSTEM IS BASED ON THE CALIFORNIA COORDINATE SYSTEM, ZONE II NAD 83, (EPOCH 2010.00), HOLDING GPS CONTROL POINT MONUMENT WITH THE NGS PERMANENT IDENTIFIER (PID) JT9617 (N 1,818,294.49, E 6,488,778.77). SEE "WWW.NGS.NOAA.GOV" FOR POINT DATA SHEETS AND DESCRIPTIONS. RTK GPS WAS USED TO ESTABLISH LOCAL CONTROL POINTS ON SITE: LCC CP 9 (N 1,805,287.37, E 6,498,458.39 - GPS COORDINATE HELD HERE), A MAGNETIC NAIL SET ON

THE NORTHEAST EDGE OF THE ASPHALT CONCRETE ROAD LEADING TO THE EXISTING TANK, AS SHOWN HEREON, AND LCC CP 108 (N 1,805,031.24, E 6,498,452.91), A CUT "+" ON THE TOP OF CURB ON THE SOUTH SIDE OF

GOHEEN CIRCLE OPPOSITE OF THE DRIVEWAY TO THE TANK ACCESS ROAD, AS SHOWN HEREON. DISTANCES AND COORDINATES AS SHOWN

ON THIS SURVEY SHOULD BE CONSIDERED AS GROUND DISTANCES AND COORDINATES.

VERTICAL DATUM

ELEVATIONS SHOWN HEREON ARE BASED ON THE CITY OF VALLEJO DATUM.

PROJECT BENCHMARK

ELEVATIONS ARE BASED ON CITY OF VALLEJO BENCHMARK, A SQUARE CUT ON TOP OF CURB OPPOSITE PG&E BOX IN FRONT OF NO. 444

SKYLINE DRIVE (NORTH SIDE OF SKYLINE), THE ELEVATION IS HELD AS 302.035 FEET (CITY DATUM).

NAVD88 CONVERSION
THE CONVERSION FROM CITY OF VALLEJO VERTICAL DATUM TO NAVD88 IS APPROXIMATELY GIVEN BY THE FOLLOWING:

CITY OF VALLEJO VERTICAL DATUM PLUS 9.4 FT = NAVD88
(APPROXIMATELY).

THIS INFORMATION IS PROVIDED FOR REFERENCE ONLY. ALL

CONSTRUCTION SHALL BE COMPLETED USING THE CITY OF VALLEJO DATUM AND STATED PROJECT BENCHMARK.

1. THE FIELD WORK FOR THIS SURVEY WAS CONDUCTED DECEMBER 2022 BY LCC ENGINEERING & SURVEYING, INC.

2. UTILITIES SHOWN ARE BASED UPON SURFACE OBSERVATIONS OF STRUCTURES FOUND IN THE FIELD. THE SURVEYOR ASSUMES NO

RESPONSIBILITY FOR LOCATIONS, CAPACITIES OR FUNCTIONALITY OF ALL UTILITIES SHOWN HEREON. SOME UNDERGROUND UTILITIES MAY NOT BE SHOWN.

3. THE BOUNDARY (PROPERTY) LINES SHOWN ON THIS MAP ARE
BASED ON SOLANO COUNTY RECORD MAPS: FINAL MAP OF
RIDGECREST, VALLEJO, CA (RM B033P097), AND RECORD OF
SURVEY, SKYVIEW RESERVOIR PARCEL, (RS B11P045), AND FOUND STREET MONUMENTS IN GOHEEN CIRCLE.

4. THIS SURVEY DOES NOT REPRESENT A COMPLETE BOUNDARY
SURVEY. ALL PROPERTY CORNERS HAVE NOT BEEN SEARCHED

FOR OR LOCATED (OTHER THAN THE FOUND STREET MONUMENTS

IN THE SURROUNDING SUBDIVISIONS PER THE LISTED RECORD
MAPS - NOT SHOWN ON THIS EXHIBIT). NEW CORNERS OR
MONUMENTS HAVE NOT BEEN SET DURING THIS SURVEY. THE

BOUNDARY (PROPERTY) LINES SHOWN HEREON ARE APPROXIMATE
AND ARE BASED ON RECORD INFORMATION ONLY. FURTHER

SURVEY AND BOUNDARY ANALYSIS WOULD BE REQUIRED TO

DETERMINE PROPERTY LINES WITH GREATER ACCURACY, IF
REQUIRED.

5. NO ATTEMPT WAS MADE TO IDENTIFY THE NATURE OF USE OF UNDERLYING LAND SHOWN HEREON. ANY POTENTIAL PAST USES,

INCLUDING THOSE WHICH MAY HAVE RESULTED IN SIGNIFICANT

ENVIRONMENTAL OR CULTURAL IMPACTS, WERE NOT ASSESSED BY THIS SURVEY.

6. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ON THIS SITE, CONTRACTOR SHALL REVIEW SECTION 8771 AND SECTION 8725 OF

THE CALIFORNIA BUSINESS AND PROFESSIONS CODE, AND
SECTION 605 OF THE CALIFORNIA PENAL CODE TO ENSURE THAT MONUMENT CONSERVATION HAS BEEN PROPERLY ADDRESSED.

7. BOUNDARY LINES (STREET CENTERLINES, ROAD RIGHTS-OF-WAY, PARCEL LINES, EASEMENTS, ETC.) ARE PLOTTED FROM RECORD
INFORMATION ONLY.

8. NOTHING ON THIS SURVEY SHALL BE INTERPRETED IN A MANNER CONTRARY TO THE ABOVE STATEMENTS.

SURVEYOR'S NOTES:

CONTROL POINT TABLE

POINT NUMBER NORTHING EASTING ELEVATION DESCRIPTION
9 1805287.37 6498458.39 261.60 MAG NL
108 1805031.24 6498452.91 248.47 CUT + ON TC
110 1805380.24 6498469.91 261.60 MAG NL
111 1805541.74 6498382.11 261.89 MAG NL
112 1805418.02 6498227.75 262.23 MAG NL
113 1805509.63 6498219.36 262.03 MAG NL
114 1805569.01 6498290.72 262.13 MAG NL
CP#110
CP#111
CP#9
CP#112
CP#113
CP#114
CP#108
APN 0081-050-100

TO CITY DISTRIBUTION SYSTEM
EX-24" SD
(CMP)
EX-24" SD
(CMP)
EX-24" W
(PCCP)
EX-12" D
(ACP)

GEOTECHNICAL BORINGS
BORING # NORTHING EASTING
B1 1805435.75 6498401.24
B2 1805554.21 6498351.66
B3 1805555.93 6498274.34
B4 1805486.49 6498219.41
B5 1805395.40 6498260.80
LOCATIONS SHOWN ARE APPROXIMATE.

SEE APPENDIX A TO SPECIFICATIONS FOR BORING DATA.

B1
B3 B2
B4
B5
EX 12KV PRIMARY FEED
Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 11:48:45-07'00'

Page 1456 of 1832 ends

PROJECT NO.

LAST SAVED BY:

FILE NAME:

Plot Date:

NKM
AL
DGB
G06
6 GENERAL

CONTRACTOR SITE ACCESS AND

TRAFFIC ROUTING PLAN
201631G06.dwg
ALaico
201631-100000
9/12/2022 7:29:07 AM

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444

1. REFER TO SECTION 01140 AND THE GENERAL AND SPECIAL
PROVISIONS FOR ADDITIONAL REQUIREMENTS.

2. CONTRACTOR SHALL LIMIT ALL CONSTRUCTION TRAFFIC TO THE ACCESS ROUTES AS SHOWN. ANY DEVIATIONS SHALL BE

APPROVED BY THE ENGINEER IN WRITING PRIOR TO USING
ALTERNATE ROUTES FOR CONSTRUCTION TRAFFIC.

SITE ACCESS AND ROUTING NOTES:

SCALE:

FILE:

PLAN
201631G06A

A NO SCALE

PROJECT

LOCATION
GOHEEN
CIRCLE

REDWOOD PARKWAY
INTERSTATE 80

OAKWOOD AVENUE

TENNESSEE STREET

SKYLINE DRIVE
Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 11:47:54-07'00'

Page 1457 of 1832 ends

GOHEEN CIR.

LAIR CT.
250
251
252
253
254
255
256
257
258
259
260
261
262
263
265
264
263
269
268
267
266
271
270
249
249
248
248
W
W
W
W W W
G
G
G
G
G
G
W
W
W
W W
W
W
PROJECT NO.

LAST SAVED BY:

FILE NAME:

Plot Date:

NKM
AL
DGB
C01
7 CIVIL

SITE PLAN
201631C01.dwg
TDonnell
201631-100000
9/12/2022 7:29:07 AM

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
GENERAL NOTES:

SKYVIEW
RESERVOIR 2

GOHEEN CIR

1. ALL SITE INGRESS AND EGRESS SHALL BE MADE THROUGH THE EXISTING ACCESS GATE FROM GOHEEN CIRCLE. SEE SECTION 01140 FOR WORK RESTRICTIONS.

2. NOT ALL EXISTING SITE FEATURES TO REMAIN ARE SHOWN ON THIS DRAWING. SUBSURFACE FEATURES OMITTED FOR CLARITY. REFER TO DRAWING C02 FOR SITE DEMOLITION REQUIREMENTS.

3. CONTRACTOR IS ADVISED THAT SUPPLEMENTAL GEOTECHNICAL

INVESTIGATION (BY CITY) WILL BE REQUIRED FOLLOWING
DEMOLITION OF SKYVIEW RESERVOIR 1. WORK WITHIN THE
FOUNDATION FOOTPRINT OF SKYVIEW RESERVOIR 2 SHALL NOT
PROCEED WITHOUT WRITTEN NOTICE BY CITY. SEE SECTION 01140 FOR ADDITIONAL REQUIREMENTS AND INFORMATION.

4. SEE SECTION 01140 FOR RESTRICTIONS ON USE OF SECONDARY STAGING AREA.

5. OFFSITE 24" WATER MAIN (ALTERNATE BID ITEM) IMPROVEMENTS NOT SHOWN. SEE DWGS C06 AND C07 FOR ALTERNATE BID ITEM
PLANS AND DETAILS.

EXIST YARD LIGHT
(TO REMAIN)

EXIST ACCESS

GATE (TO REMAIN)

SITE INGRESS/

EGRESS PATH

PERIMETER FENCE

PRIMARY

STAGING AREA
APN 0081-050-100

DRAINAGE EASEMENT TO CITY
(1580 OR 609)

GATE MOTOR

OPERATORS

SITE ACCESS GATE

W/ CARD READER

EXIST ELECTRICAL TRANSFORMER
(TO REMAIN)

EXIST ELECTRICAL PANEL
(TO REMAIN)

EXIST YARD LIGHT
(TO REMAIN)

DRAIN/OVERFLOW

CATCH BASIN

RESERVOIR

CONTROL

VALVE VAULT
100'50'0 25'
SCALE: 1" = 50'

SECONDARY

STAGING AREA

CONNECT TO EXISTING

WATER MAIN
24' W

CONNECT TO EXISTING

WATER MAIN
SEE DWG C04 FOR YARD

PIPING CONTINUATION
EX 12 KV PRIMARY FEED
Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:10:26-07'00'

Page 1458 of 1832 ends

PROJECT NO.

LAST SAVED BY:

FILE NAME:

Plot Date:

NKM
AL/TD
DGB
C02
8 CIVIL

DEMOLITION PLAN
201631C02.dwg
atucker
201631-100000
9/12/2022 7:29:07 AM

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
40'20'0 10'
SCALE: 1" = 20'

MATCH LINE - SEE BELOW LEFT

MATCH LINE - SEE ABOVE RIGHT

1. DEMOLISH EXISTING SKYVIEW RESERVOIR 1. SEE SECTION 01140 FOR REQUIREMENTS AND WORK RESTRICTIONS.

2. REMOVE ALL EXISTING BOLLARDS.

3. PROTECT IN PLACE EXISTING SITE LIGHTING, ELECTRICAL BOXES AND CONDUIT. FIELD VERIFY CONDUIT LOCATION.

4. PROTECT IN PLACE EXISTING ELECTRICAL PANEL, SERVICE, AND TRANSFORMER.

5. REMOVE EXISTING UNDERDRAIN PIPING SYSTEM AND ASSOCIATED (6) INSPECTION WELLS. RECORD DRAWINGS INDICATE THAT

UNDERDRAIN PIPING AND INSPECTION WELLS ARE CONSTRUCTED
OF ACP. REFER TO SECTION 01354 FOR HANDLING, REMOVAL, AND DISPOSAL REQUIREMENTS FOR HAZARDOUS MATERIALS.

6. REMOVE EXISTING 36" CONCRETE MANHOLE. REFER TO SECTION 01354 FOR HANDLING, REMOVAL, AND DISPOSAL REQUIREMENTS
FOR HAZARDOUS MATERIALS.

7. REMOVE EXISTING SD AS REQUIRED TO ALLOW FOR INSTALLATION OF 24" SD (DRAWING C04) AND OTHER SITE IMPROVEMENTS.

EXISTING SD PIPELINE SEGMENTS WITH GREATER THAN 3 FEET OF

COVER AT PROPOSED FINISHED GRADE AND NOT IN CONFLICT WITH OTHER IMPROVEMENTS MAY REMAIN IN PLACE. CAP ENDS OF SD
SEGMENTS TO REMAIN IN PLACE AND FILL WITH CLSM.

8. PROTECT IN PLACE EXISTING SCADA ANTENNA FASTENED TO
LIGHTPOLE.

9. PROTECT IN PLACE EXISTING CATCH BASIN.

10. PROTECT IN PLACE EXISTING PG&E BOX.

11. FIELD LOCATE AND REMOVE EXISTING ANCHOR BLOCK AT 24" W ANGLE POINT. SEE DRAWING C05 FOR ADDITIONAL CONNECTION
REQUIREMENTS.

12. REMOVE EXISTING CONDUIT. FIELD VERIFY LOCATION.

13. WELD STEEL CAP ON EXISTING 24" W AND ABANDON IN PLACE PER SECTION 01738. EXISTING 24" W IS ASSUMED TO BE PCCP.

CONTRACTOR SHALL VERIFY PRESENCE OF PRESTRESSING WIRE
PRIOR TO CUTTING. NOTIFY ENGINEER OF PRESTRESSING IS NOT FOUND.

14. EXISTING DRAINAGE FACILITIES TO REMAIN IN PLACE.

PRE-CONSTRUCTION DRAINAGE PATHWAYS SHALL BE MAINTAINED. # KEY NOTES:

EXIST

INSPECTION

WELL (TYP)
5 SKYVIEW
RESERVOIR 1
8 EXIST MAIN ELEC PANEL

EXIST UTILITY TRANSFORMER
6 2

EXIST AC

PAVEMENT
EX-12" SD (RCP)

EXIST GATE

EXIST PG&E

ELEC BOX
4 1
CP#110
CP#9
CP#111
CP#114
CP#113
CP#112
CP#108

GOHEEN CIR
3 7

1. UNLESS SPECIFICALLY CALLED OUT FOR DEMOLITION IN

THIS SHEET, EXISTING FACILITIES SHALL BE PROTECTED
IN PLACE.

2. PAVEMENT DEMOLITION AND REMOVAL NOT SHOWN FOR
CLARITY. SEE DRAWING C03 FOR EXTENT OF PAVEMENT
INSTALLATION. ALL EXISTING PAVEMENT WITHIN THESE
LIMITS SHALL BE DEMOLISHED.

3. CONTRACTOR IS ADVISED THAT SUPPLEMENTAL

GEOTECHNICAL INVESTIGATION (BY THE CITY) WILL BE

REQUIRED FOLLOWING DEMOLITION OF SKYVIEW
RESERVOIR 1. WORK WITHIN THE FOUNDATION
FOOTPRINT OF SKYVIEW RESERVOIR 2 SHALL NOT
PROCEED WITHOUT WRITTEN NOTICE BY THE CITY. SEE
SECTION 01140 FOR ADDITIONAL REQUIREMENTS AND
INFORMATION.

4. RECORD DRAWINGS FOR THE EXISTING RESERVOIR WILL

BE MADE AVAILABLE FOR CONTRACTOR REVIEW DURING
THE BID ADVERTISEMENT PERIOD. CONTRACTOR IS

RESPONSIBLE FOR DEMOLITION OF ALL EXISTING

MATERIALS WITHIN THE PROJECT SITE REQUIRED FOR
CONSTRUCTION OF THE NEW RESERVOIR.

GENERAL NOTES:
10 EXIST CATCH BASIN 9
3 EX-6" SD
EX-6" D
EX-24" SD
EX-18" SD
EX-24" W
EX-24" SD
11 DEMOLISH AND REMOVE
LEGEND:

EXIST SECONDARY FEED
12 EXIST 12KV PRIMARY FEED
13 REMOVE EXISTING 24" W
ABANDON EXISTING 24" W

IN PLACE
14 14
14 Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:09:39-07'00'

Page 1459 of 1832 ends

103
104
105
110
111
112
113 114
115
116
117
118
119
120
121
123
124
125
126
107
108
109
301 302
303
304
305
306
307
308
309
310
311
312
122
101
102
106
127
262
265
270
5' 14.71' 5'

COORDINATE CONTROL POINTS
POINT
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127

NORTHING
1805378.24
1805387.50
1805369.05
1805359.79
1805400.72
1805407.86
1805399.88
1805392.73
1805400.49
1805393.00
1805395.27
1805474.18
1805550.82
1805548.55
1805469.64
1805556.04
1805568.72
1805570.17
1805472.99
1805474.63
1805384.91
1805340.73
1805349.61
1805358.49
1805417.74
1805421.86
1805471.91

EASTING
6498355.92
6498370.18
6498382.16
6498367.90
6498364.73
6498373.10
6498379.91
6498371.55
6498372.16
6498353.99
6498264.18
6498221.24
6498268.11
6498357.91
6498400.85
6498288.90
6498285.56
6498285.18
6498398.04
6498224.09
6498311.48
6498397.89
6498408.53
6498419.18
6498385.45
6498388.28
6498311.05

ELEVATION
260.02
260.03
259.54
259.53
260.67
260.67
260.67
260.67
260.57
260.70
260.96
261.72
262.10
261.68
260.89
262.34
262.08
262.50
260.95
261.78
260.75
259.25
259.53
259.08
260.71
260.76
255.79

DESCRIPTION
FG
FG
FG
FG
FG
FG
FG
FG
RIM
RIM
RIM
RIM
RIM
RIM
RIM
FG
LG
TC
FG
FG
FG
LG
FG
LG
FG
FG

CENTER OF TANK

FENCE COORDINATES
POINT
301
302
303
304
305
306
307
308
309
310
311
312

NORTHING
1805303.03
1805311.67
1805317.50
1805441.36
1805537.11
1805623.76
1805602.11
1805591.88
1805581.61
1805555.55
1805428.37
1805351.72

EASTING
6498368.28
6498340.69
6498261.54
6498164.51
6498186.81
6498311.60
6498418.09
6498475.25
6498483.70
6498490.38
6498465.02
6498426.39

DESCRIPTION
FENCE
FENCE
FENCE
FENCE
FENCE
FENCE
FENCE
FENCE
FENCE
FENCE
FENCE
FENCE
PROJECT NO.

LAST SAVED BY:

FILE NAME:

Plot Date:

NKM
AL/TD
DGB
C03
9 CIVIL

PAVING AND GRADING
PLAN
201631C03.dwg
atucker
201631-100000
9/12/2022 7:29:07 AM

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
40'20'0 10'
SCALE: 1" = 20'

MATCH LINE - SEE BELOW LEFT

MATCH LINE - SEE ABOVE RIGHT

SKYVIEW
RESERVOIR 2
REMOVE EXISTING ASPHALT SECTION. REPLACE WITH
4" TYPE A AC OVER 6" CLASS 2 AGGREGATE BASE, 95%
RELATIVE COMPACTION. SEE SECTION 02742A FOR
ADDITIONAL INFORMATION. INSTALL GEOTEXTILE

FABRIC BETWEEN AGGREGATE BASE AND SUBGRADE
PER SECTION 02621.

LEGEND:

1. REFER TO PROJECT NOTES ON DRAWING G03.

2. SURFACE FEATURES AND SUBSURFACE UTILITIES NOT IDENTIFIED ON DRAWING C02 FOR DEMOLITION SHALL BE PROTECTED IN PLACE.

3. SEE STRUCTURAL AND MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.

1. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION.

2. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.

3. CONFORM TO EXISTING GRADE AT TOE OF EMBANKMENT.

POST-CONSTRUCTION DRAINAGE PATH SHALL MATCH
PRE-CONSTRUCTION DRAINAGE PATH.

4. INSTALL RIP RAP APRON BETWEEN CURB TERMINATION TO EXISTING CATCH BASIN AS SHOWN. RIP RAP APRON SHALL BE 93 SQUARE FEET MINIMUM. FINAL PLACEMENT AND EXTENTS TO BE DETERMINED BY CONSTRUCTION MANAGER.

5. REPLACE SIDEWALK AND DRIVEWAY ENTRANCE PER CITY STANDARD DETAIL 3-13. CONFORM TO EXISTING GRADES AND SIDEWALK
DIMENSIONS. PROTECT EXISTING CATCH BASIN AND PG&E ELECTRICAL BOX IN PLACE.

6. 8-FOOT FENCE WITH 6-STRAND BARBED WIRE. SEE SECTION 02820 FOR ADDITIONAL REQUIREMENTS.

7. EXISTING GATE TO REMAIN. PROTECT IN PLACE. REMOVE AND

RE-INSTALL IF REQUIRED TO COMPLETE PAVING IMPROVEMENTS AS SHOWN.

8. PROTECT IN PLACE. MATCH GRADE AT RIM.

9. 3'-0" WIDE PERSONNEL GATE WITH PADLOCK.

10. GATE OPERATOR. COORDINATE FINAL PLACEMENT WITH
CONSTRUCTION MANAGER. LOCATE OPERATOR TO AVOID CONFLICT WITH PERSONNEL GATE.

GENERAL NOTES:
# KEY NOTES:

GOHEEN CIR

RESERVOIR CONTROL
VALVE VAULT 260

EXIST MAIN ELEC PANEL

EXIST UTILITY TRANSFORMER
1 DRAIN/OVERFLOW

CATCH BASIN
1 2
TYP
CR102
3 EXIST CATCH BASIN
5 EXIST PG&E

ELEC BOX
4 4
C05
GRADE
BREAK
262
262
FL @ 1.0% MIN

FROM GRADE BREAK

TO END OF CURB
FL @ 0.7% MIN

FROM GRADE BREAK

TO END OF CURB
2% MIN
261
261
CARD
FL 259.14 READER
INLET INV 258.80
INLET INV 258.70
FL 258.90
6 FL 262.00
260
TYP
(TYP) CF161
260
255
250
8 7 EXIST GATE
260
HH-1 (SEE ELEC DWGS)
TYP
CF202
TYP
AG229 (TYP)
1 EXTERIOR LADDER
TYP
(TYP) CF161
11 TYP
CF161 (TYP)
10 9
12 11. SUPPORT FAN ON 6" THICK CONCRETE PAD W/ #4 REINF @ 12" EW. SEE DWG M02 FOR ADDITIONAL INFORMATION.

12. 16' WIDE DOUBLE-LEAF ENTRANCE GATE. SEE SECTION 02820 AND DETAIL CF202/TYP.

13. 12' WIDE DOUBLE-LEAF ENTRANCE GATE. SEE SECTION 02820 AND DETAIL CF202/TYP.

14. INSTALL REDWOOD HEADER PER CR106/TYP AT ALL ASPHALT

EDGES WHERE NOT BOUNDED BY A CURB, FOOTING, TANK
WALL, OR OTHER CONCRETE STRUCTURE.
10 13
TYP
CR106
14 TYP
CR106
14 Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:09:25-07'00'

Page 1460 of 1832 ends

201
203 202
204
205
206
207
208
209
210
211
W

COORDINATE CONTROL POINTS
POINT
201
202
203
204
205
206
207
208
209
210
211

NORTHING
1805358.23
1805388.37
1805383.28
1805376.39
1805384.11
1805405.26
1805436.83
1805473.05
1805509.14
1805544.11
1805551.79

EASTING
6498382.03
6498355.00
6498347.16
6498309.96
6498273.63
6498242.86
6498222.36
6498215.65
6498223.32
6498247.35
6498259.17

CENTERLINE
251.00
251.00
251.00
251.00
251.00
251.00
251.00
251.00
251.00
251.00
251.00

DESCRIPTION

TEE W/BF
90° BEND

22.5° BEND

22.5° BEND

22.5° BEND

22.5° BEND

22.5° BEND

22.5° BEND

22.5° BEND

22.5° BEND
90° BEND
PROJECT NO.

LAST SAVED BY:

FILE NAME:

Plot Date:

NKM
AL/TD
DGB
C04
10 CIVIL

YARD PIPING
PLAN
201631C04.dwg
atucker
201631-100000
9/12/2022 7:29:07 AM

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
40'20'0 10'
SCALE: 1" = 20'

1. REFER TO PROJECT NOTES ON DRAWING G03.

2. SEE CORROSION PROTECTION DRAWINGS FOR ADDITIONAL
METALLIC PIPELINE INSTALLATION DETAILS.

3. ALL PRESSURE PIPELINES SHALL BE FULLY RESTRAINED. SEE SECTION 02693 FOR ADDITIONAL INFORMATION.

4. TRENCH PIPING PER CY111/TYP AND SECTION 02318.

1. CAP AND ABANDON EXISTING 24" W PER DWG C02.

2. COORDINATE FINAL LOCATION OF COMBINATION AIR VALVE
ASSEMBLY WITH CONSTRUCTION MANAGER. RESTORE GRADE
AND DRAINAGE PATH TO PRECONSTRUCTION CONDITIONS.

3. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION.

4. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.

5. INSTALL 24" W AT 0% SLOPE.

6. INLET PIPE FLOOR PENETRATION. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL INFORMATION.

7. INSTALL PERFORATED LEAK DETECTION PIPELINE AT INVERT ELEVATION 249.08 (SLOPE=0.0%). SEE RESERVOIR STRUCTURAL SECTIONS AND DETAILS FOR ADDITIONAL INFORMATION.

8. INSTALL 6 LEAK INSPECTION WELLS AT EQUAL SPACING ALONG LEAK DETECTION PIPELINE.

9. INSTALL TWO SELF-RESTRAINED DIP JOINTS SPACE AT 5 FEET.

JOINT NEAREST TO TANK OR STRUCTURE SHALL BE PLACED 1

FOOT FROM EDGE OF CONCRETE FOUNDATION, EXTERIOR
STRUCTURE WALL, OR PIPE ENCASEMENT.

10. 14" SDR 26 HDPE DUCT FROM VALVE VAULT TO EXHAUST FAN.

INSTALL DUCT AT MINIMUM 36" COVER WITH MINIMUM 2% UPWARD SLOPE TO EXHAUST FAN.

GENERAL NOTES:
# KEY NOTES:

SKYVIEW
RESERVOIR 2

SEE STRUCTURAL DWGS

FOR CONTINUATION
(INLET)
SEE DWG C02 FOR

ABANDONMENT
EX-24" W
2 24" W
24" SD
24" W
INV OUT = 257.00

EXIST SDCB
RIM=259.6±
24" INV IN (NW)=254.3
EX-18" INV IN (SW)=249.9±
EX-24" INV OUT (NE)=249.9±
(OUTLET)
24" W
8 (TYP)
4" LDP
5 RESERVOIR CONTROL

VALVE VAULT

DRAIN/OVERFLOW

CATCH BASIN
3 4
7 92 LF @
S=2.93%
TYP
CY745
TYP
CY715
2 C05
(INLET/OUTLET)
1 C05
6 6
9 9
1 M02
10 HH-1 (SEE ELEC DWGS)
FAN-1 1
24" W
SEE DWG C07 FOR

CONTINUATION
(TO PIT)
4" W
Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:09:00-07'00'

Page 1461 of 1832 ends

NKM
GL
DGB
C05
11 CIVIL

SECTION AND DETAILS
201631-100000 201631C05.dgn
N
Yaroshuk
24" SD
2'-0"
30"
10 "
3 "
M
IN
12 "
M
IN
6 "
C
LR
24" W
EX-24" W (PCCP)

CONNECTION TO EXISTING CATCH BASIN
20163100C0400
C04 NO SCALE
1 CY257
CONNECTION TO EXISTING 24" W
20163100C0400
C06 1/2" = 1'-0"
3 INSPECTION WELL
20163100C0400
C04 NO SCALE
2 EX-36"SD (CMP)
EX-24"SD (CMP)
EX-24" SD (CMP)

ROCK LINED DRAINAGE CHANNEL
20163100C0400
C03 NO SCALE
4 3'-0"
6 "
9 "
2 4
5 3
2'-0"
A
-
20163100C0400
- 1/2" = 1'-0"
A
EX-24" W (PCCP)
7 6
6 1
24" STL SPOOL (TYP)
SEE DWG C06 FOR CONTINUATION
2'-0"

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
P
lotD
ate: 8
-S
E
P
-2025 10:52:45
AM
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

CL CATCH BASIN

EXIST WELD COLLAR

OR EQUAL)
(CALDER STYLE

COUPLING

REPAIR BAND

WELD COLLAR
2'-0" CLR OF EXIST

CUT EXIST CMP

CL INSPECTION WELL

PAVEMENT

SHALL MATCH

TOP OF COVER

FRAME WITH CI RIM AND COVER

VALVE BOX OR MANHOLE
HS20 TRAFFIC RATED
ASTM C76, CLASS III, WALL B
15" (MIN DIA) REINF CONC PIPE PER

WHERE SOIL IS UNSTABLE
8" MIN ABC UNDER BASE

UNDISTURBED SOIL OR

CAST BASE AGAINST
CONCRETE BASE.

CAST-IN-PLACE CLASS "A"
#5 @12 EW
3" EPOXY GROUT

STEEL TROWEL FINISH

TOP OF PIPE WITHIN WELL
DRAIN PIPE. CUT OUT
4" PVC PERFORATED
CLASS "A" CONCRETE

AC PAVEMENT
(FROM SKYLINE DRIVE)

FIELD VERIFY
TYP

FINISHED GRADE

CL FINISHED GRADE
PROTECTION PER SECTION 02372
"LIGHT CLASS" STONE SLOPE
RIPRAP

FILTER FABRIC

GEOTEXTILE

NON-WOVEN
INSULATED.

1. ALL CONNECTIONS BETWEEN DISSIMILAR METALS SHALL BE
#
FOR REPAIR BAND COUPLING.

EXISTING 24" SD PRIOR TO PREPARING SHOP DRAWING SUBMITTAL

7. CONTRACTOR SHALL FIELD VERIFY OUTSIDE DIAMETER OF
NOT FOUND.

PRIOR TO CUTTING. NOTIFY ENGINEER IF PRESTRESSING WIRE IS

CONTRACTOR SHALL VERIFY PRESENCE OF PRESTRESSING WIRE

6. EXISTING 24" W PIPE MATERIAL IS ASSUMED TO BE PCCP.

SIZE DISTRIBUTION.

VOIDS. HAND PLACEMENT MAY BE NECESSARY TO OBTAIN EVEN

SO IT FORMS A DENSE, UNIFORM, WELL GRADED MASS WITH FEW

5. REFER TO DRAWING C03 FOR LIMIT OF PLACEMENT. PLACE ROCK SECTION 02620 FOR ADDITIONAL INFORMATION.

FILTER FABRIC SPLICES SHALL HAVE 18" MINIMUM OVERLAP. SEE PLACE THE ROCK AS SOON AS THE FOUNDATION IS PREPARED.

4. PLACE NON-WOVEN FILTER FABRIC OR GRAVEL FILTER LAYER AND OVERCUT FOR THICKNESS OF ROCK AND FILTER FABRIC.

3. EXCAVATE THE CROSS SECTION TO THE GRADES SHOWN ON PLANS.

FRAME IN GROUT.

2. LOCATE WELL COVER ON DOWNSTREAM SIDE OF WELL. SET WELL INFORMATION.

1. SEE CATHODIC PROTECTION DRAWINGS FOR ADDITIONAL
GENERAL NOTES:

KEY NOTES:

INSULATING KIT PER CP DWGS
24" FLANGE CONNECTION W/
(INLET/OUTLET)

WSP DIP

PER CP DWGS

INSULATING KIT

CONNECTION W/
24" FLANGE

WSP DIP
CY301/TYP

HOLES PER
MIN 3 PASS

CONTINUATION
SEE DWG C06 FOR
S
TA
0+00
S
TA
0+00
Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:10:50-07'00'

Page 1462 of 1832 ends

236
240
244
248
252
256
260
264
268
-0+25 0+00 1+00 2+00 3+00 4+00 EX 8" SS INV=242.7± EX 6" SS INV=249.6± EX 1" W INV=245.7± EX 4" SS INV=242.4± EX 1" W INV=246.0± EX 1" W INV=250.9± EX 4" SS INV=251.9± EX 4" SS INV=256.0± STA=0+05 CL=259.44 24" 45° HORZ BEND EX 1" W INV UNK

4.42%

0.00%
STA=0+19.96
CL=258.83
24" 45° HORZ BEND

0.00%
STA=0+62.40
CL=257.07
24" 11.25° HORZ BEND

7.99%
STA=0+93.29CL=254.64
24" 11.25° HORZ BEND

7.86%
STA=1+34.08CL=251.48
24" 11.25° HORZ BEND

8.33%
STA=1+61.56
CL=249.23
24" 11.25° HORZ BEND

8.20%
STA=2+03.80
CL=245.81
24" 11.25° HORZ BEND

0.00%
STA=2+16.30CL=245.81
24"x14" TEE

0.00%
STA=2+30.67
CL=245.81
24" 11.25° HORZ BEND

2.56%
STA=2+73.38CL=244.73
24" 11.25° HORZ BEND

0.78%
STA=3+03.46
CL=244.50
24" 11.25° HORZ BEND
STA=2+13.94
24" BFV
STA=2+18.63
24" BFV

4.21%

0.67%
SKYLINE DR.
251
252
253
254
255
256
257
258
259
260
262
261
263
261
262
263
264
265
266
267
268
269
270
271
W
W
W
W
W
W
W
W
G
G
G
G
G
G
G
G
G G
W
W
W
W
W
W
W
W
W
W
W
W
W W
0+00
1+00
2+00
24" 45° BEND
N=1804842.99
E=6498093.68
24" 45° HORZ BEND
N=1804853.42
E=6498082.95
24" 11.25° HORZ BEND
N=1804895.85
E=6498083.73
24" 11.25° HORZ BEND
N=1804926.23
E=6498089.37 24" 11.25° HORZ BEND
N=1804964.01
E=6498104.73
24" 11.25° HORZ BEND
N=1804987.00
E=6498119.78
24" 11.25° HORZ BEND
N=1805017.13
E=6498149.39
14" W
N 1804837.99
E 6498093.66
24" W
GOHEEN CIR.
250
251
252
253
249
249
W
W
W
W
W
W W W
W
W
G G
G
G
G
G
W
W
W
W
W
W
W
2+00
3+00
4+00
24" 11.25° HORZ BEND
N=1805032.27
E=6498171.59
24" 11.25° HORZ BEND
N=1805048.96
E=6498210.91
24" 11.25° HORZ BEND
N=1805054.81
E=6498240.41
14" W
24" W
24"x14" TEE
N 1805024.17
E 6498159.72
14" 22.5° BEND
N 1805058.22
E 6498136.22
SCALE
KEY NOTES:

1. DIP WATER MAIN. SEE SECTION 02693.

2. 24"x14" TEE W/ TWO BUTTERFLY VALVES AND ONE 14"
BUTTERFLY VALVE. INSTALL VALVES PER CY715/TYP.

3. INSTALL 14" WATER MAIN AT CONSTANT SLOPE
BETWEEN POINTS OF CONNECTION.

4. APPROXIMATE TIE-IN LOCATION. CONTRACTOR SHALL
POTHOLE EX. WATER MAIN TO VERIFY PIPE MATERIAL
AND DEPTH PRIOR TO CONSTRUCTION. COORDINATE
WITH CITY STAFF FOR THE SHUTDOWN OF THE EX.

WATER MAIN. CUT-IN TO EXISTING 14" DIP WATER
MAIN WITH 14" 90° HORZ BEND AND MECHANICAL
JOINT ADAPTERS. INSTALL THRUST BLOCK PER
CY131/TYP.

5. APPROXIMATE TIE-IN LOCATION. CONTRACTOR SHALL
POTHOLE EX. WATER MAIN TO VERIFY PIPE MATERIAL
AND DEPTH PRIOR TO CONSTRUCTION. COORDINATE
WITH CITY STAFF FOR THE SHUTDOWN OF THE EX.

WATER MAIN. FOR PURPOSES OF BIDDING, ASSUME
EX. 24" W IS PCCP. COMPLETE CONNECTION TO EX.
24" WITH 2'-0" SEGMENT OF WSP AND BUTT STRAP
WELD PER DET. 3/C05.

6. FIELD VERIFY ELEVATION OF EXISTING WATER
SERVICES. IF WATER SERVICE IS IN CONFLICT WITH
24" W, CONTRACTOR SHALL REROUTE SERVICE
LATERAL TO PROVIDE MINIMUM 6" VERTICAL
CLEARANCE TO 24" W WITH AT LEAST 24" COVER ON
WATER SERVICE. SEE CITY STANDARD DETAIL 4-04
FOR MATERIAL REQUIREMENTS.
(HORIZ)
10'5'0 2.5'
SCALE: 1" = 5'
GENERAL NOTES:

1. ALL PRESSURE PIPELINES SHALL BE FULLY
RESTRAINED. SEE SECTION 02693 FOR ADDITIONAL
INFORMATION.

2. ALL DUCTILE IRON WATER MAINS SHALL BE FULLY
BONDED PER DET. 4/CP03. "CATHODIC PROTECTION
GENERAL NOTES" ON DWG CP01 SHALL APPLY TO ALL
DUCTILE IRON PIPING SHOWN ON DWGS C06 AND C07.

PROVIDE INSULATING JOINTS PER DET. 1/CP04 AND
2/CP04 AT CONNECTIONS TO EXISTING WATER MAINS.

BID PRICING SHALL INCLUDE 3 INSULATING JOINT
TEST STATIONS WITH (2)-32 LB ANODES (AT EACH

IJTS) ON GOHEEN CIRCLE AND/OR ACCESS ROAD PER
DET. 1/CP02. THE TESTING OF THE INSULATING

JOINTS SHALL BE CONDUCTED IN THE PRESENCE OF

THE OWNER'S REPRESENTATIVE AND APPROVED BY

THE REPRESENTATIVE PRIOR TO FINAL ACCEPTANCE
AND BACKFILL. COORDINATE FINAL PLACEMENT OF
TEST STATIONS WITH CONSTRUCTION MANAGER.

3. CONTRACTOR SHALL POTHOLE AND VERIFY

LOCATIONS OF ALL EXISTING UTILITIES PRIOR TO
CONSTRUCTION. ALL POTENTIAL CONFLICTS OR

CONDITIONS THAT DO NOT ALLOW FOR THE

REQUIRED SEPARATION DISTANCES SHALL BE

BROUGHT TO THE ATTENTION OF THE
CONSTRUCTION MANAGER WITHIN 5 WORKING DAYS
OF POTHOLING.

4. MAINTAIN MIN 3' SEPARATION BETWEEN PROPOSED

WATER MAIN AND EXISTING WATER MAIN AND GAS
LINES.

5. MAINTAIN MIN 10' HORIZONTAL AND 0.5' VERTICAL

SEPARATION BETWEEN PROPOSED WATER MAIN AND
EXISTING SEWER AND STORM DRAIN LINES. WATER

MAINS SHALL CROSS ABOVE SEWER AND STORM
DRAIN LINES.

6. WHERE REQUIRED SEPARATION TO EXISTING SEWER

AND STORM DRAIN LINES CANNOT BE ACHIEVED, OR

WHERE THE WATER MAIN MUST BE CONSTRUCTED

BELOW A SEWER OR STORM DRAIN LINE, CONSTRUCT
NEW WATER MAIN WITHOUT PIPE JOINTS WITHIN 10'

OF EITHER SIDE OF THE OUTSIDE DIAMETER OF THE
SEWER OR STORM PIPE BARREL. ENCASE WATER
MAIN PER MP003/TYP. ENCASEMENT SHALL EXTEND
10' BEYOND THE OUTSIDE BARREL OF THE STORM OR
SEWER PIPELINE.

7. ABANDON WATER MAINS WHERE INDICATED PER
SECTION 01738.
0 10' 20' 40'
SCALE: 1" = 20'
(VERT)
FILE:

PLAN
20163100C102

PROFILE
FILE: 20163100C102
#
PROJECT NO.

LAST SAVED BY:

FILE NAME:

Plot Date:

JCP
TD
DGB
C06
12 CIVIL
24" WATER MAIN
PLAN AND PROFILE 1
201631C06.dwg
atucker
201631-100000
9/12/2022 7:29:07 AM
usanorth811.org

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
MATCH LINE STA 4+15 SEE DWG C07
268
264
260
256
252
248
244
240
236
MATCH LINE STA 4+15 SEE DWG C07
MATCH LINE STA 2+10 SEE RIGHT
MATCH LINE STA 2+10 SEE LEFT

SKYLINE DRIVE

3.5'
MIN
415' OF 24" DUCTILE IRON PIPE (PC 200 PER SECTION 02001)

EX GRADE
1 3
EX-14" W
EX-24" W

CONNECT TO
EX 14" W (DIP)
4 GOHEEN CIRCLE
EX-8" SS
EX-8" W
1 EX-6" SS

EX-SS LAT
EX-8" SS

CONNECT TO
EX 24" W (PCCP) 5
EX-24" W

ABANDON IN PLACE
1 2
EX-14" W
EX-24" W
6" MIN CLR
5 5'

ABANDON IN PLACE
TYP
CY131
BACKFILL PIPE TRENCH WITH CLSM TO AC SECTION FROM STA 0+00 TO STA 2+50 6" MIN CLR 6" MIN CLR 6" MIN CLR
6 6
6 6
6 6
6 6
Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:10:39-07'00'

Page 1463 of 1832 ends

236
240
244
248
252
256
260
264
268
5+00 6+00 7+00 8+00 9+00 EX 8" W INV=244.7±
EX 4" SS
INV=241.6±
EX 1" W
INV=245.3±
EX 4" SS
INV=241.9±

0.73%

0.20% 0.05% 1.78%

11.69%
STA=4+99.55CL=243.19
24" 45° HORZ BENDSTA=5+25.72CL=243.01
24" 45° HORZ BEND

0.67%
EX 12" SD
INV=248.0±
EX 18" SD
INV=251.6±
EX 12" SD
INV=250.5±
STA=7+74.93CL=255.25
24" 22.5° HORZ BEND
STA=7+22.62CL=255.25
24" 22.5° HORZ BEND
STA=8+07.83CL=254.68
24" 22.5° HORZ BEND
STA=8+40.25CL=251.00
24" 22.5° HORZ BEND
STA=8+45.66
24" TEE

4.85%

17.76%
STA=8+07.83CL=254.68
24" 22.5° HORZ BEND
STA=6+77.23CL=255.32
24" 11.25° VERT BEND
STA=6+38.54
CL=248.44
24" 11.25° VERT BEND
W W W
SD

SS SS SS
5+00
24" 45° HORZ BEND
N=1805072.0360
E=6498455.2260
24" 45° HORZ BEND
N=1805053.7500
E=6498436.4940
24" W
SD
SD
SD
8+45.66
6+00 7+00
8+00
24" TEE
N=1805358.2313
E=6498382.0313
24" 22.5° HORZ BEND
N=1805268.9219
E=6498457.3148
24" 22.5° HORZ BEND
N=1805317.4617
E=6498437.8096
24" 22.5° HORZ BEND
N=1805340.9714
E=6498414.7934
24" 22.5° HORZ BEND
N=1805353.6935
E=6498384.9782
24" 11.25° VERT BEND
N 1805223.53
E 6498456.81
24" 11.25° VERT BEND
N 1805184.85
E 6498456.43
24" W
SCALE
(HORIZ)
10'5'0 2.5'
SCALE: 1" = 5'
0 10' 20' 40'
SCALE: 1" = 20'
(VERT)
FILE:

PLAN
20163100C102

PROFILE
FILE: 20163100C102
PROJECT NO.

LAST SAVED BY:

FILE NAME:

Plot Date:

JCP
TD
DGB
C07
13 CIVIL
24" WATER MAIN
PLAN AND PROFILE 2
201631C07.dwg
atucker
201631-100000
9/12/2022 7:29:07 AM
usanorth811.org

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
268
264
260
256
252
248
244
240
236
MATCH LINE STA 5+40 SEE RIGHT
MATCH LINE STA 4+15 SEE DWG C06 MATCH LINE STA 4+15 SEE DWG C06 MATCH LINE STA 5+40 SEE LEFT
KEY NOTES:

1. DIP WATER MAIN. SEE SECTION 02693.

2. 24" MJxFL TEE W/ BLIND FLANGE.

3. SEE DWG C04 FOR CONTINUATION.

4. COORDINATE FINAL LOCATION OF COMBINATION

AIR VALVE ASSEMBLY WITH CONSTRUCTION
MANAGER. RESTORE GRADE AND DRAINAGE
PATH TO PRECONSTRUCTION CONDITIONS.

5. FIELD VERIFY ELEVATION OF EXISTING WATER
SERVICES. IF WATER SERVICE IS IN CONFLICT
WITH 24" W, CONTRACTOR SHALL REROUTE
SERVICE LATERAL TO PROVIDE MINIMUM 6"
VERTICAL CLEARANCE TO 24" W WITH AT LEAST
24" COVER ON WATER SERVICE. SEE CITY
STANDARD DETAIL 4-04 FOR MATERIAL
REQUIREMENTS.
#
EX-8" W

3.5'
MIN

EX GRADE

GOHEEN CIRCLE

REPLACE SIDEWALK
PER DWG C03
9'±
EX-12" SD
1 EX-12" SD

ACCESS ROAD
431'± LF OF 24" DUCTILE IRON PIPE (PC 200 PER SECTION 02001) 3 2
TYP
CY745
4 TYP
CF161
TYP
CY745
4 GENERAL NOTES:

1. ALL PRESSURE PIPELINES SHALL BE FULLY
RESTRAINED. SEE SECTION 02693 FOR ADDITIONAL
INFORMATION.

2. ALL DUCTILE IRON WATER MAINS SHALL BE FULLY
BONDED PER DET. 4/CP03. "CATHODIC PROTECTION
GENERAL NOTES" ON DWG CP01 SHALL APPLY TO ALL
DUCTILE IRON PIPING SHOWN ON DWGS C06 AND C07.

PROVIDE INSULATING JOINTS PER DET. 1/CP04 AND
2/CP04 AT CONNECTIONS TO EXISTING WATER MAINS.

BID PRICING SHALL INCLUDE 3 INSULATING JOINT
TEST STATIONS WITH (2)-32 LB ANODES (AT EACH

IJTS) ON GOHEEN CIRCLE AND/OR ACCESS ROAD PER
DET. 1/CP02. THE TESTING OF THE INSULATING

JOINTS SHALL BE CONDUCTED IN THE PRESENCE OF

THE OWNER'S REPRESENTATIVE AND APPROVED BY

THE REPRESENTATIVE PRIOR TO FINAL ACCEPTANCE
AND BACKFILL. COORDINATE FINAL PLACEMENT OF
TEST STATIONS WITH CONSTRUCTION MANAGER.

3. CONTRACTOR SHALL POTHOLE AND VERIFY

LOCATIONS OF ALL EXISTING UTILITIES PRIOR TO
CONSTRUCTION. ALL POTENTIAL CONFLICTS OR

CONDITIONS THAT DO NOT ALLOW FOR THE

REQUIRED SEPARATION DISTANCES SHALL BE

BROUGHT TO THE ATTENTION OF THE
CONSTRUCTION MANAGER WITHIN 5 WORKING DAYS
OF POTHOLING.

4. MAINTAIN MIN 3' SEPARATION BETWEEN PROPOSED

WATER MAIN AND EXISTING WATER MAIN AND GAS
LINES.

5. MAINTAIN MIN 10' HORIZONTAL AND 1' VERTICAL

SEPARATION BETWEEN PROPOSED WATER MAIN AND
EXISTING SEWER AND STORM DRAIN LINES. WATER

MAINS SHALL CROSS ABOVE SEWER AND STORM
DRAIN LINES.

6. WHERE REQUIRED SEPARATION TO EXISTING SEWER

AND STORM DRAIN LINES CANNOT BE ACHIEVED, OR

WHERE THE WATER MAIN MUST BE CONSTRUCTED

BELOW A SEWER OR STORM DRAIN LINE, CONSTRUCT
NEW WATER MAIN WITHOUT PIPE JOINTS WITHIN 10'

OF EITHER SIDE OF THE OUTSIDE DIAMETER OF THE
SEWER OR STORM PIPE BARREL. ENCASE WATER
MAIN PER MP003/TYP. ENCASEMENT SHALL EXTEND
10' BEYOND THE OUTSIDE BARREL OF THE STORM OR
SEWER PIPELINE.

7. ABANDON WATER MAINS WHERE INDICATED PER
SECTION 01738.

EX-8" SS
1 6" MIN CLR
6" MIN CLR
6" MIN CLR

DUCT BANK

DUCT BANK

DUCT BANK
DUCT BANKS.

SEE DWG E02 (TYP)
1' MIN CLR
5 5
Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:09:11-07'00'

Page 1464 of 1832 ends

PROJECT NO.

LAST SAVED BY:

FILE NAME:

TDH
DJA
JDH
CP01
14 CATHODIC PROTECTION

SITE PLAN
201631CP.dwg
DAlfano
201631-100000

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
(925)927-6630 FAX (925)927-6634
WWW.JDHCORROSION.COM
Concord, CA 945201100 Willow Pass Court
40'20'0 10'
SCALE: 1" = 20'
CATHODIC PROTECTION GENERAL NOTES:

SKYVIEW
RESERVOIR 2

SEE STRUCTURAL DWGS

FOR CONTINUATION
(INLET)
EX-24" W
24" W
24" W
(OUTLET)
24" W
4" LDP
2 RESERVOIR CONTROL

VALVE VAULT

DRAIN/OVERFLOW

CATCH BASIN
3 1. THE PIPELINES WHICH ARE THE SUBJECT OF THIS CATHODIC

PROTECTION SYSTEM ARE THE YARD PIPING OF THE SKYVIEW

TANKS CONSISTING OF DUCTILE IRON PIPE, VALVES & FITTINGS OF THE POTABLE WATER OUTLET AND INLET. ALL DUCTILE IRON PIPE AND FITTINGS SHALL BE WRAPPED WITH 8-MIL POLYETHYLENE IN ACCORDANCE WITH AWWA C-105.

2. CATHODIC PROTECTION FOR THE METALLIC PIPE SHALL CONSIST

OF PREPACKAGED, HIGH POTENTIAL MAGNESIUM ANODES
INSTALLED INSTALLED IN TEST STATIONS AS SHOWN. THE ANODE SIZES ARE INDICATED ON THIS SHEET (SEE KEYNOTES).

3. ALL NON-WELDED, NON-INSULATING JOINTS SHALL BE BONDED

WITH ONE HMWPE INSULATED COPPER CABLES FOR ELECTRICAL

CONTINUITY OF THE DUCTILE IRON PIPE AND/OR FITTINGS PER DETAIL 4/CP03. CABLE-TO-PIPE CONNECTIONS TO DUCTILE IRON

PIPE AND FITTINGS SHALL BE MADE BY MEANS OF EXOTHERMIC
WELDS.

4. THE NEW PIPELINES AND FITTINGS SHALL BE ELECTRICALLY

ISOLATED FROM ALL ABOVE GRADE STRUCTURES AND FROM

EXISTING METALLIC STRUCTURES, SUCH AS REBAR, COPPER PIPE, GROUNDING CLAMPS, TRACER WIRE, EXISTING PIPE, ETC.

INSULATING JOINTS SHALL BE INSTALLED AT ALL CONNECTIONS TO

ABOVE GRADE STRUCTURES, IN-VAULT PIPE AND
INSTRUMENTATION AND TO EXISTING PIPELINES.

5. TEST STATIONS ARE REQUIRED FOR ANODE LOCATIONS ON ALL PIPES & FITTINGS.

6. ANY ADDITIONAL ANODES INSTALLED SHALL BE DOCUMENTED AND REPORT PROVIDED TO THE ENGINEER.

7. REFER TO SECTION 13100 FOR CATHODIC PROTECTION SYSTEM TESTING AND INSPECTION REQUIREMENTS.

SCALE:

FILE:

PLAN
201631CP
A 1" = 20'

CATHODIC PROTECTION SITE PLAN
1 CP02 1

1. INSTALL ON THE 24" W OUTLET CONNECTION TO THE TANK AN IJTSA W/(2)-32 LB. PREPACKAGED MAGNESIUM ANODES PER
DETAIL 1/CP02. EXTEND THE WAX TAPE COATING FROM THE
INSULATING FLANGE APPROXIMATELY 15 FEET TO THE FACE OF

THE CONCRETE ENCASEMENT WHERE THE OUTLET PIPE EXITS
FROM THE CONCRETE ENCASEMENT UNDER THE TANK.

2. INSTALL BOND CABLES ON ALL BURIED (NON-INSULATING) JOINTS OF THE 24" W OUTLET PER DETAIL 4/CP03.

3. INSTALL INSULATING JOINTS INSIDE THE RESERVOIR CONTROL

VAULT ON ALL PIPE ENTERING AND EXITING THE VAULT PER
DETAIL 1/CP04. PROVIDE ADDITIONAL GROUNDING FOR ANY
ELECTRICALLY POWERED INSTRUMENTATION IN THE VAULT.

4. INSTALL WAX TAPE COATING ON THE DUCTILE IRON PIPE OF THE 24" INLET. EXTEND THE WAX TAPE COATING FROM THE FACE OF THE VAULT APPROXIMATELY 14 FEET TO THE FACE OF THE

CONCRETE ENCASEMENT WHERE THE INLET PIPE EXITS FROM
THE CONCRETE ENCASEMENT UNDER THE TANK.

5. INSTALL ON THE 24" W OUTLET AN ATS W/(2)-32 LB. PREPACKAGED MAGNESIUM ANODES PER DETAIL 2/CP02.
# KEY NOTES:
2 CP02 5
1 CP05 4
1 CP04
1 CP04
1 CP04
SEPTEMBER 2025

Page 1465 of 1832 ends

NOTES:

1. EXTEND THE WAX TAPE COATING TO THE FACE OF THE CONCRETE ENCASEMENT.

2. COAT ALL BURIED BOLTS & NUTS WITH BITUMASTIC. ENCASE ALL DUCTILE IRON PIPE AND FITTINGS IN POLYETHYLENE PER CATHODIC PROTECTION GENERAL NOTE 1. ON SHEET CP04,

3. BOND ALL BURIED, NON-WELDED, (NON-INSULATING) DUCTILE ITON PIPE JOINTS. SEE DETAIL 4/CP03.

TANK WALL

TANK FLOOR
PIPE

TEST STATION

SEE DETAIL

PREPACKAGED MAGNESIUM ANODE (TYP)

SEE DETAIL

INSULATING FLANGE & COATING

SEE DETAIL

POLYETHYLENE

ENCASEMENT
(SEE NOTE 2.)
#10 AWG/THHN (BLACK) ANODE CABLES
#10 AWG/THHN
TEST (RED) CABLES #10 AWG HMWPE (WHITE) DRAIN CABLE
#10 AWG/THHN

TEST (WHITE) CABLE
10' MIN
(SEE NOTE 1.)
NOTES:

1. INSTALL 2" PVC PIPE IN CLEAN NATIVE SOIL. FILL PIPE WITH CLEAN SOIL, FREE FROM ROCKS & DEBRIS.

2. INSTALL 18" LENGTH OF 3/ 4" PVC PIPE TO ENSURE THAT THE TERMINAL BOX WILL REMAIN IN THE UPRIGHT POSITION. POSITION THE PIPE SO THAT THE TERMINAL BOX WILL BE AS HIGH AS POSSIBLE WITH THE CAST IRON LID STILL CLOSING PROPERLY. 12" (TYP)
NOTE:

1. IDENTIFY ALL CABLES IN THE TERMINAL BOX PER DETAIL 2 ON SHEET CP03.

CABLE-TO-PIPE

CONNECTION (TYP)

SEE DETAIL

INSULATING JOINT &

COATING

SEE DETAILS

PROTECTED PIPELINE
#10 AWG/THHN TEST

CABLE (RED)
#10 AWG/THHN BOND

CABLE (RED)
#10 AWG THHN BOND

CABLE (WHITE)
#10 AWG THHN TEST

CABLE (WHITE)

NONPROTECTED

PIPELINE
(SEE NOTE 2.)

TEST STATION

TERMINAL BOX SEE DETAIL

SEE LEFT
6"
MIN

FINISHED GRADE

TERMINAL BOX
6"
10-1/4"Ø CONCRETE TRAFFIC BOX W/CAST IRON
COVER MARKED "CP-TEST"

CONCRETE COLLAR
3000 PSI
#4 REBAR

CENTERED

IN COLLAR
PROVIDE 18" SLACK IN CABLES

TO ALLOW REMOVAL OF

TERMINAL BOX FROM TEST

STATION
6"
MIN
6"

CONCRETE
COLLAR
3000 PSI

ASPHALT CONCRETE

2.5"

TERMINAL BOX
PROVIDE 18" SLACK IN CABLES

TO ALLOW REMOVAL OF

TERMINAL BOX FROM TEST

STATION
#4 REBAR

CENTERED

IN COLLAR
10-1/4"Ø CONCRETE TRAFFIC BOX W/CAST IRON
COVER MARKED "CP-TEST"
24"
MIN
2" PVC PIPE (SEE NOTE 1.)
24"
MIN

DRAIN ROCK DRAIN ROCK

NATIVE SOIL NATIVE SOIL
12"
MIN
6"
MIN
12"
MIN
6"
MIN
3/4" PVC PIPE (SEE NOTE 2.)
2" PVC PIPE (SEE NOTE 1.)
3/4" PVC PIPE (SEE NOTE 2.)
32 LB PREPACKAGED MAGNESIUM ANODE

SEE DETAIL
#10 AWG THHN ANODE

CABLE (BLACK)
10'
(TYP)

CABLE-TO-PIPE

CONNECTION
SEE DETAIL #10 AWG/THHN DRAIN
CABLE
#10 AWG THHN TEST
CABLE
#10 AWG/THHN (BLACK)

ANODE CABLE (TYP)

DUCTILE IRON

PIPELINE
WHITE
12" (TYP)
NOTES:

1. INSTALL BOND CABLES ON ALL BURIED JOINTS (EXCEPT INSULATING JOINTS) PER TO DETAIL 4/CP03.

2. COAT ALL NUTS AND BOLTS WITH BITUMASTIC AND ENCASE ALL DUCTILE IRON PIPE AND FITTINGS IN POLYETHYLENE PER CATHODIC PROTECTION GENERAL NOTE II.A.4 ON SHEET CP01.

TEST STATION

SEE DETAIL
GRADE
6' MIN
(SEE NOTE 2.)
12" MIN
6' MIN
(SEE
NOTE 2.)

TO PIPE/FITTING
(SEE NOTE 5.)

NATIVE BACKFILL

FREE OF ROCKS &
DEBRIS

PREPACKAGED
ANODE
#10 AWG/THHN ANODE

CABLE (BLACK)
GRADE
6"
12"
12" MIN

TO PIPE/FITTING
(SEE NOTE 5.)

NATIVE BACKFILL

FREE OF ROCKS &
DEBRIS

PREPACKAGED
ANODE
#10 AWG/THHN ANODE

CABLE (BLACK)
NOTES:

1. INSTALL ANODES 3 FEET OFF THE PIPE/FITTING IN NATIVE SOIL.

2. THE ANODES MAY BE INSTALLED HORIZONTALLY OR VERTICALLY UPON DISCRETION OF THE CONTRACTOR.

3. MAINTAIN A MIN. DISTANCE OF 10 FEET BETWEEN ANODES IF MULTIPLE ANODES ARE INSTALLED.

4. CONNECT ANODE CABLE TO TEST STATION OR DIRECTLY TO PIPE OR FITTING AS SHOWN IN THE DRAWINGS.

PREPACKAGED MAGNESIUM ANODE (TYP)

SEE DETAIL
5 CP02
1 CP04
4 CP02
3 CP03
5 CP02
4 CP02
5 CP02
3 CP03
1 CP04
4 CP02
2 CP04
2 CP04

FACE OF CONCRETE ENCASEMENT
(SEE NOTE 1.)

CONCRETE

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
(925)927-6630 FAX (925)927-6634
WWW.JDHCORROSION.COM
Concord, CA 945201100 Willow Pass Court
PROJECT NO.

LAST SAVED BY:

FILE NAME:

TDH
DJA
JDH
CP02
15 CATHODIC PROTECTION
DETAILS 1
201631CP.dwg
DAlfano
201631-100000
SEPTEMBER 2025

Page 1466 of 1832 ends

0.01 OHM-8 AMP SHUNT
#10 AWG/THHN
(BLACK) ANODE CABLE
(2) #10 AWG/THHN TEST
CABLES
(WHITE-PROTECTED PIPE

RED-EXISTING PIPE)
#8 AWG/THHN TEST

CABLE (RED)

TERMINAL BOX (COVER

NOT SHOWN FOR

CLARITY)
#8 AWG/THHN (WHITE)

DRAIN CABLE

NICKEL PLATED BRASS

BINDING POST W/SET

SCREW (TYP)

0.01 OHM-8 AMP SHUNT
#10 AWG/THHN
(BLACK) ANODE CABLE
#10 AWG/THHN TEST
CABLES (BLUEPROTECTED PIPE )

TERMINAL BOX (COVER

NOT SHOWN FOR

CLARITY)
#8 AWG/THHN (BLUE)

DRAIN CABLE

NICKEL PLATED BRASS

BINDING POST W/SET

SCREW (TYP)
1/4"

DUCTILE IRON PIPE

FILL W/EPOXY TO COVER ALL

EXPOSED STEEL & COPPER A
MINIMUM OF 1/4"

EXOTHERMIC WELD

SEE DETAIL
COPPER
SLEEVE

JOINT BOND CABLE OR

TEST STATION CABLE
(SIZE AS REQ'D)

BUILD DAM W/PLUMBER'S
PUTTY

GRAPHITE COVER
SLEEVE
HANDLE

GRAPHITE MOLD
CABLE

STARTING POWDER

METAL DISC

METAL WELDING POWDER

FILE STRUCTURE CONNECTION AREA
TO BARE SHINY METAL AND CLEAN.

STRIP INSULATION FROM WIRE. ATTACH SLEEVE
REQUIRED ON #6 AWG WIRE OR SMALLER

HOLD MOLD FIRMLY WITH OPENING AWAY FROM
OPERATOR AND IGNITE WITH FLINT GUN.

REMOVE SLAG FROM CONNECTION AND PEEN
WELD FOR SOUNDNESS.

COVER CONNECTION AND EXPOSED STRUCTURE

SURFACE WITH EPOXY COATING COMPOUND OR
MORTAR PER DETAIL 3 ON DRAWING CP03.

NOTE:

PROCEDURE SHOWN ABOVE IS TO BE USED AS A GENERAL GUIDE ONLY. CONSULT MANUFACTURER'S LITERATURE FOR SPECIFIC INSTALLATION INSTRUCTIONS.

STEP 1.

STEP 2.

STEP 3.

STEP 4.

STEP 5.

PIPELINE

SURFACE

PERMANENT NYLON

MARKING TAG

WIRE INSULATION STRIPPED TO FIT

TERMINAL LUG

ABBREVIATIONS NUMBER

ANODE NUMBER

AN - ANODE

W - WATER

DR - DRAIN CABLE

TT - TEST CABLE
HMWPE BOND CABLE, 24" LONG
(SEE NOTE 2.)

CAST IRON OR STEEL COUPLING

EPOXY COATED
HMWPE BOND CABLE (SEE NOTE 2.)
DIPDIP
DIPDIP
DIPDIP
DIPDIP
(1) #8 AWG/HMWPE

BOND CABLE (TYP)
HMWPE BOND CABLE (SEE NOTE 2.)
HMWPE BOND CABLE (SEE NOTE 2.)
NOTES:

1. INSTALL ONE #8 AWG/HMWPE BOND CABLE ON EACH JOINT FOR DUCTILE IRON SETTLEMENT JOINTS.

INSTALL ONE #8 AWG/HMWPE BOND CABLE ON EACH JOINT FOR METALLIC PIPELINES OF UP TO 10-INCHES IN DIAMETER.

INSTALL ONE #4 AWG/HMWPE BOND CABLE ON EACH JOINT FOR METALLIC PIPELINES OF UP TO 18-INCHES IN DIAMETER.

INSTALL TWO #4 AWG/HMWPE BOND CABLES ON EACH JOINT FOR METALLIC PIPELINES 20" IN DIAMETER OR GREATER.

2. PROVIDE ENOUGH SLACK IN THE BOND CABLES SHALL BE OF SUFFICIENT LENGTH TO ALLOW FOR SIGNIFICANT SOIL SUBSIDENCE AND PIPE JOINT MOVEMENT.
3 CP03
5 CP03

CABLE-TO-PIPE

CONNECTION (TYP)

SEE DETAIL

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
(925)927-6630 FAX (925)927-6634
WWW.JDHCORROSION.COM
Concord, CA 945201100 Willow Pass Court
PROJECT NO.

LAST SAVED BY:

FILE NAME:

TDH
DJA
JDH
CP03
16 CATHODIC PROTECTION
DETAILS 2
201631CP.dwg
DAlfano
201631-100000
SEPTEMBER 2025

Page 1467 of 1832 ends

INSULATING SLEEVE/BUSHING

INSULATING WASHER NUT

INSTALL INSULATING

SLEEVES & WASHERS
(TYP)

STEEL WASHER
NOTES:

1. THE INSULATING FLANGE KIT SHALL BE FOR WATER SERVICE, SUITABLE FOR WET & DRY LOCATIONS, AND BE OF SAME PRESSURE RATING AS THE FLANGE.

2. THIS DETAIL IS TYPICAL FOR STEEL AND DUCTILE IRON PIPE FLANGES, AND ALSO FOR STEEL PIPE INSULATING FLEXIBLE COUPLINGS AND INSULATED RESTRAINED FLEXIBLE COUPLINGS.

3. THE ALLOY OF THE STEEL WASHERS SHALL BE THE SAME AS IS SPECIFIED FOR THE FLANGE BOLTS.

INSULATING
WASHER
STEEL
WASHER

DOUBLE NUT

INSULATING

SLEEVE/BUSHING

RESTRAING ROD
(TYP)

WELDED ANCHOR

INSULATING GASKET
(TYP)

WELD ANCHOR (TYP)

SEE ANCHOR DETAIL

TO THE RIGHT

RESTRAINING ROD (TYP)

MIDDLE RING

FOLLOWER RING (TYP)

INSULATING
GASKET

TANK SIDE PIPE

RESTRAINING ROD
(TYP)

BELOW GRADE
PIPE
FLANGE

PIPELINE

INSULATING GASKET

FLANGE BOLT

FULL LENGTH

REINFORCED PHENOLIC RESIN

OR MYLAR SLEEVE

PHENOLIC INSULATING

WASHER (TYP)

FLANGE NUT

STEEL WASHER (TYP)

BUILD UP WITH FILL COAT TO

COVER ALL NUTS AND BOLTS A
MINIMUM OF 1
4" (SEE SPECS.)

INSULATING WASHER
(TYPICAL OF 2)

STEEL WASHER
(TYPICAL OF 2)

WAX TAPE &

OUTERWRAP
(SEE SPECS.)

INSULATING SLEEVE
FLANGE

STAINLESS STEEL
NUT

STAINLESS STEEL BOLT
(SEE NOTE 4.)

INSULATING
GASKET

DUCTILE IRON

OR STEEL PIPE

BOLT (TYP)

MIDDLE RING

INSULATING

GASKET (TYP)

BUILD UP WITH FILL

COAT TO COVER

ALL NUTS AND RODS
A MINIMUM OF 1/4"
(SEE SPECS.)
(SEE NOTE 2.)

MIDDLE RING

INSULATING FOLLOWER RING (TYP)

GASKET (TYP)

WELD ANCHOR (TYP)
(SEE NOTE 2.)

RESTRAINING ROD (TYP)
SEE NOTE 4.
#8 AWG HMWPE BOND CABLES

SEE DETAIL

FOLLOWER RING (TYP)

RESTRAINING ROD (TYP)
#8 AWG HMWPE BOND CABLES
(TYP)

SEE DETAIL

BUILD UP WITH FILL COAT

TO COVER ALL NUTS AND
RODS A MINIMUM OF 1/4"
(SEE SPECS.)
(SEE NOTE 2.)

OUTER WRAP

INSULATING
GASKET
#8 AWG HMWPE BOND CABLES

SEE DETAIL
4 CP03
4 CP03
4 CP03

WAX TAPE &

OUTERWRAP
(SEE SPECS.)

WAX TAPE &

OUTERWRAP
(SEE SPECS.)

BUILD UP WITH FILL COAT

TO COVER ALL NUTS AND
RODS A MINIMUM OF 1/4"
(SEE SPECS.)
(SEE NOTE 2.)

WAX TAPE & OUTERWRAP
(SEE SPECS.)
NOTES:

1. OMIT COATING IF COUPLING IS LOCATED ABOVE GRADE OR IN VAULTS.

2. ENSURE APPLICATION OF VISCOUS ELASTIC COATING AND VISCOUS ELASTIC PASTE TO COVER ALL RESTRAINING ROD ASSEMBLIES.

3. ALL INSULATING JOINTS SHALL BE TESTED AND APPROVED PRIOR TO BACKFILL.

4. INSTALL STAINLESS STEEL RODS, BOLTS, NUTS, AND WASHERS.

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
(925)927-6630 FAX (925)927-6634
WWW.JDHCORROSION.COM
Concord, CA 945201100 Willow Pass Court
PROJECT NO.

LAST SAVED BY:

FILE NAME:

TDH
DJA
JDH
CP04
17 CATHODIC PROTECTION
DETAILS 3
201631CP.dwg
DAlfano
201631-100000
SEPTEMBER 2025

Page 1468 of 1832 ends

BOLT (TYP)

MIDDLE RING

INSULATING

GASKET (TYP)

MIDDLE RING

FOLLOWER RING (TYP)

INSULATING

GASKET (TYP)

WELD ANCHOR (TYP)
(SEE NOTE 2.)

RESTRAINING ROD (TYP)
SEE NOTE 4.
#8 AWG HMWPE BOND CABLES

SEE DETAIL

FOLLOWER RING (TYP)

RESTRAINING ROD (TYP)
#8 AWG HMWPE BOND CABLES
(TYP)

SEE DETAIL

OUTER WRAP

INSULATING
GASKET
#8 AWG HMWPE BOND CABLES

SEE DETAIL
NOTES:

1. OMIT COATING IF COUPLING IS LOCATED ABOVE GRADE OR IN VAULTS.

2. ENSURE APPLICATION OF VISCOUS ELASTIC COATING AND VISCOUS ELASTIC PASTE TO COVER ALL RESTRAINING ROD ASSEMBLIES.

3. ALL INSULATING JOINTS SHALL BE TESTED AND APPROVED PRIOR TO BACKFILL.

4. INSTALL STAINLESS STEEL RODS, BOLTS, NUTS, AND WASHERS.

5. THIS DETAIL IS TYPICAL FOR THE WAX TAPE COATING OF DUCTILE IRON PIPE OF THE INLET. 4 CP03
4 CP03
4 CP03

BUILD UP WITH FILL COAT

TO COVER ALL NUTS AND
RODS A MINIMUM OF 1/4"
(SEE SPECS.)
(SEE NOTE 2.)

WAX TAPE & OUTERWRAP
(SEE SPECS.)

WAX TAPE &

OUTERWRAP
(SEE SPECS.)

BUILD UP WITH FILL

COAT TO COVER

ALL NUTS AND RODS
A MINIMUM OF 1/4"
(SEE SPECS.)
(SEE NOTE 2.)

BUILD UP WITH FILL COAT

TO COVER ALL NUTS AND
RODS A MINIMUM OF 1/4"
(SEE SPECS.)
(SEE NOTE 2.)

WAX TAPE &

OUTERWRAP
(SEE SPECS.)

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
(925)927-6630 FAX (925)927-6634
WWW.JDHCORROSION.COM
Concord, CA 945201100 Willow Pass Court
PROJECT NO.

LAST SAVED BY:

FILE NAME:

TDH
DJA
JDH
CP05
18 CATHODIC PROTECTION
DETAILS 4
201631CP.dwg
DAlfano
201631-100000
SEPTEMBER 2025

Page 1469 of 1832 ends

201631-100000
JB
aum
barger
CE
CE
JAD
GS01
19 STRUCTURAL

GENERAL STRUCTURAL NOTES
201631GS01.dgn

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
P
lotD
ate: 9-S
E
P
-2025 10:56:02
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1 LA
S
T
S
AVED
B
Y:

PROJECT NO. FILE NAME:

GENERAL NOTES: GEOTECHNICAL REPORT / FOUNDATION DESIGN CRITERIA:

TYPICAL STRUCTURAL MATERIALS:

CONSTRUCTION: STRUCTURAL SYMBOLS:

CURED TO THEIR MINIMUM SPECIFIED 28-DAY COMPRESSIVE STRENGTH.

OF THE WALL ARE IN PLACE, ARE COMPLETE, AND (IN THE CASE OF CONCRETE) HAVE

2.DO NOT PLACE BACKFILL AGAINST WALLS UNTIL STRUCTURES SUPPORTING THE TOP PREPARED, BEFORE PROCEEDING WITH FOUNDATION CONSTRUCTION.

OBTAIN ENGINEER’S OBSERVATION OF SUBGRADE SURFACES, AS EXPOSED AND AS

1.EXPOSE AND PREPARE SUBGRADE AS SHOWN ON THE DRAWINGS AND SPECIFIED.

EXCAVATION AND BACKFILLING:

SPECIAL INSPECTION:

REINFORCING STEEL (FOR CONCRETE ):

CONCRETE:

STRUCTURAL STEEL:

STAINLESS STEEL:

B. TYPE 304L: E304L-15 ELECTRODES.

A. TYPE 316L: E316L-15 ELECTRODES.

4. WELDED CONNECTIONS:

C. TYPE 304/304L: ASTM F 593, GRADE B8, CLASS 1, HEAVY HEX.

B. TYPE 316/316L: ASTM F 593, GRADE B8M, CLASS 1, HEAVY HEX.

A. MATCH ALLOY OF THE STRUCTURAL MEMBERS CONNECTED.

3. BOLTED CONNECTIONS - BOLTS AND ANCHOR BOLTS:

2. SECTIONS: SHAPES AND BARS: ASTM A 276.

1. ANSI TYPE 316/316L EXCEPT WHERE TYPE 304/304L IS INDICATED ON THE DRAWINGS.

STRUCTURAL ALUMINUM:

ALLOY 4043 ELECTRODES.

A. GAS METAL ARC (MIG) OR GAS TUNGSTEN ARC (TIG) PROCESS USING FILLER

3. WELDED CONNECTIONS:

A. STAINLESS STEEL - TYPE 316, ASTM F 593, GRADE B8M, CLASS 1, HEAVY HEX.

2. BOLTED CONNECTIONS - BOLTS AND ANCHOR BOLTS:

B. SHEET AND PLATE: ASTM B 209, ALLOY 6061-T6.

A. SHAPES: ASTM B 308, ALLOY 6061-T6.

1. SECTIONS
STRUCTURAL ABBREVIATIONS:

DEFERRED DESIGN SUBMITTALS
BRACING, AND BALANCING.

THEIR DESIGN STRENGTH, PROTECT STRUCTURES AS REQUIRED BY SHORING, FACILITIES. UNTIL CONSTRUCTION IS COMPLETE AND MEMBERS HAVE ACHIEVED

STRUCTURES HAVE BEEN DESIGNED FOR OPERATING LOADS ON COMPLETED

9. CONSTRUCTION LOADS:

STRUCTURAL DESIGN CRITERIA - GENERAL:

A. DESIGN RAINFALL INTENSITY: i = 1.32 INCHES / HOUR. (100 YEAR/1 HOUR EVENT)

8. RAIN LOADS:
( * 5% DAMPED)
C. DESIGN SPECTRAL RESPONSE ACCELERATIONS:*
B. MAXIMUM CONSIDERED ACCELERATIONS:*
A. SITE CLASS: C.

7. EARTHQUAKE DESIGN DATA:

C. BASIC WIND SPEED (3 SEC GUST, 33 FEET ABOVE GROUND): 99 MPH.

B. WIND-BORNE DEBRIS REGION:

A. SPECIAL WIND REGION:

6. WIND DESIGN DATA:

5. FLUID PRESSURE LOADS: 62.4 PSF/FT (UNO).

E. CONCENTRATED AND IMPACT LOADS: SEE PLANS.

D. EQUIPMENT LOADS: SEE PLANS.

C. ROOF LIVE LOAD: SEE PLANS (20 PSF MINIMUM).

B. GRATING AND CHECKERED PLATE: 100 PSF (UNO).

A. FLOOR LIVE LOAD: SEE PLANS.

4. LIVE LOADS: (REDUCTIONS NOT USED)

3. DEAD LOADS: CALCULATED FOR STRUCTURE SELF-WEIGHT.

2. STRUCTURE RISK CATEGORY: IV.

B. LOCAL AMENDMENTS: 2022 CALIFORNIA BUILDING CODE.

A. 2021 INTERNATIONAL BUILDING CODE (“IBC 2021”) WITH ASCE 7-16.

1. BUILDING CODE:

THESE OVERALL CRITERIA FOR THE SITE.

SEE DRAWINGS OF INDIVIDUAL STRUCTURES FOR SPECIFIC DESIGN CRITERIA BASED ON NO
NO

2. PRESTRESSING STRANDS: ASTM A 416, 270 KSI YIELD STRENGTH, 7-WIRE.

B. WHERE INDICATED ON THE DRAWINGS: ASTM A 706.

A. TYPICAL: ASTM A 615, GRADE 60.

1. DEFORMED BARS:

THE DRAWINGS.

CONFORM TO THE FOLLOWING REQUIREMENTS UNLESS OTHERWISE INDICATED ON ITS MINIMUM SPECIFIED 28-DAY COMPRESSIVE STRENGTH.

STRUCTURE ABOVE IS COMPLETE AND (IN THE CASE OF CONCRETE) HAS CURED TO ARE COMPLETE, PROVIDE BRACING FOR WALLS. KEEP BRACING IN PLACE UNTIL THE

3. WHERE BACKFILL MUST BE PLACED AGAINST WALLS BEFORE STRUCTURES ABOVE FOR DETAILED AND LOCATION-SPECIFIC REQUIREMENTS.

2. SEE PROJECT SPECIFICATIONS AND NOTES ON DRAWINGS OF SPECIFIC STRUCTURES OTHERWISE INDICATED ON THE DRAWINGS.

1.MATERIALS SHALL CONFORM TO THE FOLLOWING REQUIREMENTS UNLESS 1) BOLTING.

C.STRUCTURAL ALUMINUM.
1) HIGH-STRENGTH BOLTING.

B.STRUCTURAL STEEL (CARBON AND STAINLESS).
4) ANCHORS - POST-INSTALLED MECHANICAL AND ADHESIVE.
3) ANCHORS - CAST-IN AND BUILT-IN ANCHOR BOLTS.
2) MEMBER SIZES/TYPES.
1) MEMBER LOCATIONS.

A.GENERAL ALL METALS:

4.DIVISION 5 METALS
H.PRECAST CONCRETE.

G.PRESTRESSED CONCRETE.

F.PROTECTION AND CURING PROCEDURES.

E.CONCRETE MIX AND PLACEMENT.

D.ANCHORS: CAST-IN AND POST-INSTALLED.

C.REINFORCING STEEL.

B.FORMWORK AND MEMBER SIZES.

A.LOCATIONS.

3.DIVISION 3 CONCRETE:

D.FILL AND BACKFILL.

C.PREPARATION OF SOILS/SURFACES SUPPORTING CONSTRUCTION.

B.ADEQUACY OF EXPOSED SURFACE TO PROVIDE REQUIRED SUPPORT.

A.EXCAVATION DEPTH.

2.DIVISION 2 SITE CONSTRUCTION (EARTHWORK)
AND CONSTRUCTION. SEE SPECIFICATION SECTION 01455 FOR DETAILS.

1.SPECIAL INSPECTION IS REQUIRED FOR THE FOLLOWING STRUCTURAL MATERIALS A. 13207 STRAND-WOUND CIRCULAR PRESTRESSED CONCRETE TANK

2. DIVISION 13 SPECIAL CONSTRUCTION.

A. 03300 CONCRETE MIX DESIGNS

1. DIVISION 3 CONCRETE.

DEFERRED DESIGN SUBMITTALS FOR THIS PROJECT INCLUDE:

SUBSEQUENTLY SUBMITTED TO THE BUILDING OFFICIAL.

THAT ARE TO BE REVIEWED BY THE REGISTERED DESIGN PROFESSIONAL AND

OF THE DESIGN THAT ARE NOT SUBMITTED AT THE TIME OF PERMIT APPLICATION, AND

AS DEFINED IN THE BUILDING CODE, DEFERRED DESIGN SUBMITTALS ARE PORTIONS 4500 6000

DISCREPANCIES
D. SEE MECHANICAL DRAWINGS FOR EQUIPMENT PADS AND PIPE SUPPORTS.

AND ASSOCIATED STRUCTURAL REQUIREMENTS.

C. SEE MECHANICAL DRAWINGS FOR DETAILS OF PIPE PENETRATIONS, PIPE SUPPORTS, DIAMETER ARE NOT SHOWN ON THE STRUCTURAL DRAWINGS.

B. IN GENERAL, OPENINGS, EMBEDMENTS, AND PENETRATIONS LESS THAN 12 INCHES IN ITEMS AND EQUIPMENT FURNISHED.

A. CONFIRM SIZE AND LOCATIONS OF OPENINGS, PENETRATIONS AND EMBEDMENT FOR STRUCTURES.

CONDUITS, AND OTHER ITEMS THAT ARE EMBEDDED INTO OR PASS THROUGH

7.DRAWINGS PREPARED BY OTHER DISCIPLINES INCLUDE OPENINGS, ANCHORS, PIPES, TO WHICH SITE COORDINATES REFER ARE SHOWN ON THE STRUCTURAL PLANS.

6.SEE CIVIL DRAWINGS FOR STRUCTURE COORDINATES. POINTS ON THE STRUCTURES ORIENTATION REQUIRED AT THAT STRUCTURE.

CONCRETE) IS GENERALLY ARBITRARY. SEE DRAWINGS OF EACH STRUCTURE FOR REINFORCEMENT (WHETHER “LINES” OR “DOTS”ARE CLOSER TO THE FACE OF THE B. IN STRUCTURAL TYPICAL DETAILS, ORIENTATION OF BARS IN EACH MAT OF TITLES, EVEN WHEN NOT SPECIFICALLY REFERENCED ON THE DRAWINGS.

A. TYPICAL DETAILS ARE INTENDED TO APPLY AT LOCATIONS DESCRIBED BY THEIR

5.TYPICAL DETAILS ARE INCLUDED ON THE “TS” DRAWINGS.

B. SIZES AND LOCATIONS OF EQUIPMENT PADS FOR EQUIPMENT SELECTED.

A. DIMENSIONS AND WEIGHTS FOR EQUIPMENT SELECTED.

FOLLOWING BEFORE PREPARATION AND SUBMITTAL OF SHOP DRAWINGS:

DIMENSIONS, AND INFORMATION SHOWN ON THESE DRAWINGS. CONFIRM THE

IMMEDIATELY OF BETWEEN EXISTING CONDITIONS AND

4.VERIFY DIMENSIONS AND CONDITIONS BEFORE BEGINNING WORK. ADVISE ENGINEER SHOWS CONSTRUCTION AT AND BELOW ELEVATION 110.)
C. PLANS ARE TREATED AS HORIZONTAL SECTIONS. (I.E.: “PLAN AT ELEVATION 110” B. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED SIZES.

A. SCREENED LINE WORK INDICATES EXISTING CONDITIONS.

3.PRESENTATION CONVENTIONS FOR STRUCTURAL DRAWINGS:

INDICATED IN THE GENERAL NOTES AND TYPICAL DETAILS.

2.UNLESS DETAILED, SPECIFIED, OR INDICATED OTHERWISE, CONSTRUCTION SHALL BE AS DISCIPLINES AND WITH THE SPECIFICATIONS.

1.USE STRUCTURAL DRAWINGS IN CONJUNCTION WITH PROJECT DRAWINGS BY OTHER E.PRECAST MEMBERS: f’c = 5000 PSI.

D.ELECTRICAL DUCT ENCASEMENT: “CLASS CE” f’c = 3000 PSI.

C.PIPE ENCASEMENT: “CLASS A” f’c = 4000 PSI.

B.FILL AND THRUST BLOCKS: “CLASS C” f’c = 2500 PSI.

A.STRUCTURES: “CLASS A” f’c = 4000 PSI.

2.MINIMUM SPECIFIED CONCRETE COMPRESSIVE STRENGTH, f’c (AT 28 DAYS UNO).

1.NORMAL DENSITY.

FASTEN GRATING TO SUPPORTS AS INDICATED IN S559/TYP.

C.UNLESS INDICATED ON THE DRAWINGS AS “REMOVABLE GRATING”, SECURELY B.GRATING AND ITS SEATS OR SUPPORTS SHALL BE OF THE SAME MATERIAL.

OTHERWISE NOTED.

A.ALUMINUM WITH TYPE 316 STAINLESS STEEL FASTENERS, UNLESS

2.GRATING:

A.ALUMINUM, EXCEPT WHERE OTHER MATERIALS ARE NOTED.

1.HANDRAILS AND GUARDRAILS:

METAL FABRICATIONS:

SLIDING COEFFICIENT OF FRICTION: 0.35
PASSIVE (PSF/FT): 350
SOIL SEISMIC, INVERSE TRIANGULAR LOAD (PSF/FT): 40
AT REST (PSF/FT): 65
ACTIVE (PSF/FT): 45
SURCHARGE: EQUIVALENT TO 2 FEET OF SOIL ABOVE FINISHED GRADE.

B. LATERAL EARTH PRESSURE (UNO):

A. NET ALLOWABLE BEARING PRESSURE (PSF): STATIC SEISMIC INVESTIGATION REPORT.

2. FOUNDATION DESIGNS ARE BASED ON RECOMMENDATIONS IN THE GEOTECHNICAL REPORT NO: E9149-04-03 DATED: MAY 2023.

PREPARED BY:GEOCON CONSULTANTS, INC.

TITLE: GEOTECHNICAL AND GEOLOGIC HAZARDS INVESTIGATION.

1. GEOTECHNICAL INVESTIGATION REPORT:
(AWS) A2.4.

2.WELDING: SYMBOLS: IN ACCORDANCE WITH AMERICAN WELDING SOCIETY DEFINITION OF MATERIALS SHADING PATTERNS.

1. SEE DRAWING G03 FOR KEY TO DRAWING TITLES AND SECTION CUTS, AND FOR

BAR SIZE)
# NUMBER (REINFORCING
T.O. TOP OF
O.F. OUTSIDE FACE
I.F. INSIDE FACE

EF EACH FACE PL PLATE

BO BOTTOM OF L ANGLE
REINFORCEMENT: OTHER:

ABBREVIATIONS HAVE THE MEANINGS LISTED.

WHEN USED ON THE STRUCTURAL DRAWINGS, THE FOLLOWING

4. ABBREVIATIONS FOR STRUCTURAL DRAWINGS:

THE ALUMINUM ASSOCIATION’S ALUMINUM DESIGN MANUAL, CURRENT EDITION.

B. ALUMINUM: ABBREVIATIONS AND DESIGNATIONS ARE IN ACCORDANCE WITH MANUAL, CURRENT EDITION.

AMERICAN INSTITUTE OF STEEL CONSTRUCTION’S STEEL CONSTRUCTION A. STEEL: ABBREVIATIONS AND DESIGNATIONS ARE IN ACCORDANCE WITH THE

3. STRUCTURAL MEMBERS:

PROJECT SPECIFICATIONS.

2. ABBREVIATIONS FOR NAMES OF TECHNICAL GROUPS MAY BE FOUND IN THE

1. SEE DRAWING G04 FOR GENERAL LIST OF ABBREVIATIONS USED ON DRAWINGS.

C. WELDS - SHIELDED METAL ARC PROCESS USING E70-XX ELECTRODES.

ASTM F 1554, GRADE 36 GALVANIZED.

ASTM F 593, STAINLESS TYPE 316 (304)
ANCHOR BOLTS WITH HEX FORGED HEAD.

B. BOLTS - STEEL TO CONCRETE OR MASONRY:

WASHERS.

ASTM F 3125 GRADE A325 HIGH-STRENGTH BOLTS, WITH LOAD INDICATOR A. BOLTS - STEEL TO-STEEL:

2. CONNECTIONS:

SQUARE AND RECTANGULAR: ASTM A 500, GRADE B (Fy = 46 KSI) ROUND: ASTM A 500, GRADE B (Fy = 42 KSI)
E. HOLLOW STRUCTURAL SECTIONS:

D. PIPES: ASTM A 53, GRADE B (Fy = 35 KSI)
C. PLATES AND BARS: ASTM A 36 (Fy = 36 KSI)
B. SHAPES S, ST, M, MT, HP, C, MC, L: ASTM A 36 (Fy = 36 KSI) A. SHAPES W, WT: ASTM A 992 (Fy = 50 KSI)

1. SECTIONS
ANCHORS.

LOCATIONS OF REINFORCEMENT IN MEMBERS BEFORE DRILLING HOLES FOR ANCHORS. USE NON-DESTRUCTIVE TESTING EQUIPMENT TO IDENTIFY B.DO NOT CUT, DAMAGE, OR INTERRUPT EXISTING REINFORCEMENT TO INSTALL EVALUATION REPORT AND MANUFACTURER’S INSTRUCTIONS.

A.INSTALL IN FULL COMPLIANCE WITH ACCEPTED BUILDING CODE

4.POST-INSTALLED ANCHORS IN CONCRETE:

ALUMINUM SURFACES AS SPECIFIED IN SECTION 09960.

B.WHERE ALUMINUM IS IN CONTACT WITH MASONRY OR CONCRETE, COAT ISOLATING SLEEVES AND WASHERS AS SPECIFIED IN SECTION 05190.

AND STAINLESS STEEL, OR ALUMINUM AND STEEL) PROVIDE
A.AT BOLTED CONNECTIONS THAT INCLUDE DIFFERENT METALS (E.G.: STEEL

3.INTERFACE BETWEEN MATERIALS:

BEING JOINED, AND FULL LENGTH OF THE JOINT.

A.FILLET WELDS: PER AWS CODE BASED ON THE THICKNESS OF THE MATERIALS

2.WELDED:

EDGE OF A PLATE OR STRUCTURAL ELEMENT.

C.WITH A DISTANCE OF AT LEAST 1 1/2 INCHES FROM CENTER OF BOLT TO ANY CENTER.

B.HAVING A MINIMUM OF 2 BOLTS, SPACED NOT CLOSER THAN 3 INCHES ON A.MADE USING 3/4-INCH DIAMETER BOLTS.

1.BOLTED:

STEEL, STAINLESS STEEL, AND ALUMINUM - CONNECTIONS:

B.HOUSEKEEPING PAD FOR ELECTRICAL EQUIPMENT SEE S350/TYP.

A.EQUIPMENT PAD SEE S302/TYP.

8. CONCRETE PADS

7.FINISH CONCRETE AS SPECIFIED IN SECTION 03366.

AND EMBEDMENTS.

6.MAINTAIN MINIMUM 3 INCHES CLEAR CONCRETE COVER BETWEEN REINFORCING DRAWINGS OR ACCEPTED IN ADVANCE BY THE ENGINEER.

5.WELDING OF REINFORCING IS NOT PERMITTED UNLESS DETAILED ON THE B.AT OPENINGS - AS INDICATED IN S180/TYP.

ADDED BARS WHERE INDICATED ON THE DRAWINGS.

A.AT CORNERS AND JUNCTIONS - AS INDICATED IN S144/TYP, SUPPLEMENT WITH

4.PROVIDE REINFORCING:

SPECIFICATION 03102 FOR CHAMFERS.

3.PROVIDE CHAMFER AT EXPOSED EDGES OF CAST-IN-PLACE CONCRETE. SEE ACCEPTANCE BY THE ENGINEER BEFORE FORM LAYOUT.

2.SUBMIT LOCATIONS OF CONSTRUCTION JOINTS NOT SHOWN ON THE DRAWINGS FOR LENGTH REQUIREMENTS FOR REINFORCING.

1.SEE S101/TYP FOR CONCRETE NOTES, INCLUDING CLEAR COVER AND LAP SPLICE CONCRETE:

Sds = 1.673 g Sd1 =0.799 g
Sms = 2.510 g Sm1 = 1.199 g

0.2 SECOND *1.0 SECOND
Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:24:16-07'00'

Page 1470 of 1832 ends

D
4 1
2 3
5 6
7 A B C E G

7.5° 7.5°
R 89'-0" MIN
R 86'-0"
R 83'-0"
R 76'-0"
HPT 255.69
HPT
(TYP ALL AROUND)
HPT 255.00

SWALE LINE LPT
(TYP ALL AROUND)
LPT 254.93
5 EQ SPACES @ 24'-6" = 122'-6"
5 EQ SPACES @ 24'-6" = 122'-6"
36" SST HINGED
MANWAY
(TYP) @

MANWAYS
6 S05
C
S03
E
S03
2 S04
D
S03
5°
36" SST HINGED
MANWAY
G
S04
4 S05
F
WATER

SAMPLING

STATION
3 S05
U
S09

FOUNDATION
PLAN
22'-0"
17'-0" V
S09
UPPER
PLAN
10°

13.5°

6.5°
INLET PIPE 24" W
OUTLET PIPE 24" W
10°
9 S06
(TYP)
8 S06
(TYP)
14 S08

FLOOR CJ
(TYP)

COORDINATE

CONTROL POINT

SEE CIVIL DWGS

9.25°

8.25°
45°
E
S03
SIM
GENERAL NOTES:

1. FOR GENERAL STRUCTURAL NOTES, REFER TO DRAWING GS01.

2. SEE DRAWING S03 FOR THE TANK DESIGN CRITERIA.

3. THE TANK SHALL BE AN AWWA D110, TYPE I, STRAND WOUND,

PRESTRESSED CONCRETE TANK DESIGNED AND CONSTRUCTED BY

QUALIFIED TANK CONTRACTOR IN ACCORDANCE WITH THE
REQUIREMENTS SET FORTH IN SPECIFICATION 13207.

4. DRAWINGS SHOW THE GENERAL ARRANGEMENT FOR AWWA D110, TYPE I TANK. DETAILED ASPECTS OF THE TANK, INCLUDING

SHOTCRETE, WATERSTOPS, BEARING PADS, REINFORCING STEEL, PRESTRESSING CONNECTIONS, SEISMIC CABLES, JOINTS, ETC. ARE

EXAMPLES AND SHALL BE COORDINATED WITH TANK
MANUFACTURER.

5. ALL STAINLESS STEEL SHALL BE A MINIMUM OF 316/316L FOR WELDING FABRICATIONS UNLESS NOTED OTHERWISE.

6. FOR WATERSTOP SEE DETAILS S106/TYP & S107/TYP. WATERSTOP SHALL BE CONTINUOUS WITH CLOSED LOOP ALL AROUND JOINTS.

7. CONSTRUCTION JOINT SPACING AND LOCATIONS AS REQUIRED BY TANK MANUFACTURER. FOR CONSTRUCTION JOINT SEE DETAIL
S110/TYP.

8. COORDINATE FINAL EDGE DISTANCE OF BELOW-SLAB INLET AND OUTLET PIPES WITH TANK SUPPLIER.

9. STRUCTURAL DRAWINGS S01 THROUGH S08 SHOW THE GENERAL

ARRANGEMENT AND REQUIRED APPURTENANCES FOR AN AWWA
D110, TYPE I TANK. PROPORTIONS AND DETAILS OF THE TANK

ELEMENTS, SUCH AS WALL THICKNESS, REINFORCING STEEL, JOINT LOCATIONS, ETC. ARE NOT SPECIFIED AND/OR SHOWN ON THE
DRAWINGS. UNLESS OTHERWISE INDICATED, DETAILS NOT SHOWN

SHALL BE DETERMINED BY THE TANK MANUFACTURER IN

ACCORDANCE WITH THE DESIGN REQUIREMENTS SET FORTH IN
SECTION 13207.

10. SEE DETAIL S102/TYP FOR CIRCULAR WALL LAP SPLICE
INFORMATION.

11. REFER TO DRAWINGS GS01 AND S03 FOR SEISMIC DESIGN CRITERIA. 1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN
DESIGNED JOB NO.

DRAWING NO.

SHEET NO.

VERIFY SCALES

IF NOT ONE INCH ON

THIS SHEET, ADJUST

SCALES ACCORDINGLY

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF
FILE NAME:
59 PLOT DATE:

SEPTEMBER 2025

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
201631
9/9/2025 11:13:33 PM
R:\d0163181\20163100S0801.rvt
S01

SKYVIEW RESERVOIR
FOUNDATION PLAN 20

STRUCTURAL
JAD
JBB
MAE
SCALE:

PLAN A 3/32" = 1'-0"
Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:25:07-07'00'

Page 1471 of 1832 ends

GENERAL NOTES:

1. FOR GENERAL STRUCTURAL NOTES, REFER TO DRAWING GS01.

2. SEE DRAWING S03 FOR THE TANK DESIGN CRITERIA.

3. THE TANK SHALL BE AN AWWA D110, TYPE I, STRAND WOUND,

PRESTRESSED CONCRETE TANK DESIGNED AND CONSTRUCTED BY

QUALIFIED TANK CONTRACTOR IN ACCORDANCE WITH THE
REQUIREMENTS SET FORTH IN SPECIFICATION 13207.

4. DRAWINGS SHOW THE GENERAL ARRANGEMENT FOR AWWA D110, TYPE I TANK. DETAILED ASPECTS OF THE TANK, INCLUDING

SHOTCRETE, WATERSTOPS, BEARING PADS, REINFORCING STEEL, PRESTRESSING CONNECTIONS, SEISMIC CABLES, JOINTS, ETC. ARE

EXAMPLES AND SHALL BE COORDINATED WITH THE TANK
MANUFACTURER.

5. THE HORIZONTAL LIFELINE FALL PROTECTION SYSTEM SHALL BE

COMPRISED OF COMPONENTS MANUFACTURED BY DBI-SALA FOR
THE SAFE LINE SYSTEM. THE INSTALLED SYSTEM AND ALL

ASSOCIATED COMPONENTS SHALL MEET ALL APPLICABLE OSHA
SAFETY REGULATIONS.

6. ALL STAINLESS STEEL SHALL BE A MINIMUM OF 316/316L FOR WELDING FABRICATIONS UNLESS NOTED OTHERWISE.

7. STRUCTURAL DRAWINGS S01 THROUGH S08 SHOW THE GENERAL

ARRANGEMENT AND REQUIRED APPURTENANCES FOR AN AWWA
D110, TYPE I TANK. PROPORTIONS AND DETAILS OF THE TANK

ELEMENTS, SUCH AS WALL THICKNESS, REINFORCING STEEL, JOINT LOCATIONS, ETC. ARE NOT SPECIFIED AND/OR SHOWN ON THE
DRAWINGS. UNLESS OTHERWISE INDICATED, DETAILS NOT SHOWN

SHALL BE DETERMINED BY THE TANK MANUFACTURER IN

ACCORDANCE WITH THE DESIGN REQUIREMENTS SET FORTH IN
SECTION 13207.

8. SEE DETAIL S102/TYP FOR CIRCULAR WALL LAP SPLICE
INFORMATION.

9. REFER TO DRAWING GS01 AND S03 FOR SEISMIC DESIGN CRITERIA.

D
4 1
2 3
5 6
7 A B C E G
5 EQ SPACES @ 24'-6" = 122'-6"
5 EQ SPACES @ 24'-6" = 122'-6"
TYP
6"W X 6"T S184

ALL AROUND
L
(TYP ALL AROUND)
LPT 299.60
C
S03

ALUM ROOF VENT
D
S03
F
42" SQ

ACCESS HATCH

AL LADDER W/

SAFETY CLIMB DEVICE

AL GUARDRAIL
(TYP ALL AROUND) TYP
AC504

AL GUARDRAIL GATE
TYP
AC514

ROOF CJ
(TYP)
12 S07
5 S05

ROOF DRAIN SCUPPER W/
GALV STEEL PIPE. (TYP 10

PLACES EQUALLY SPACED)
4'-0" X 8'-0" DOUBLE LEAF

ACCESS HATCH, FINAL

PLACEMENT BY TANK

CONTRACTOR
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN
DESIGNED JOB NO.

DRAWING NO.

SHEET NO.

VERIFY SCALES

IF NOT ONE INCH ON

THIS SHEET, ADJUST

SCALES ACCORDINGLY

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF
FILE NAME:
59 PLOT DATE:

SEPTEMBER 2025

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
201631
9/9/2025 11:13:38 PM
R:\d0163181\20163100S0801.rvt
S02

SKYVIEW RESERVOIR
ROOF PLAN 21

STRUCTURAL
JAD
JBB
MAE
SCALE:

PLAN B 3/32" = 1'-0"
Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:25:30-07'00'

Page 1472 of 1832 ends

CONCRETE WALL

ASSEMBLY

FIN SURFACE, SEE CIVIL DWGS

WATERSTOP
1 2
SEE DETAIL 1 / -

FOR OMITTED

SUBGRADE

PREPARATION

INFORMATION

CONCRETE WALL

FOOTING & SLAB

EXTEND CONC

WALL FOOTING

AS REQUIRED
TOC 255.00

BEGIN SLOPE

TO SWALE
3'-0"
TYP
MP003

ENCASEMENT

REINFORCING STEEL
MUST BE INSTALLED 2"

MINIMUM FROM ANY

PORTION OF PIPE
1% SLOPE 1% SLOPE

ANCHORED

FLEXIBLE-BASE

CONNECTION
15 S08

SUBGRADE PREP
SIMILAR TO DETAIL 1

SEE CIVIL FOR

CONTINUATION

SUBGRADE PREP SIMILAR TO
DETAIL 1
24" W
9'-0"
1 INLET OR OUTLET PIPE
CL 251.00
40 DUROMETER RUBBER SEAL (TYP)

PVC WATERSTOP (TYP)
GENERAL NOTES:

1. FOR GENERAL STRUCTURAL NOTES, REFER TO DRAWING GS01.

2. SEE ADDITIONAL NOTES ON SHEET S01.

3. THE TANK DESIGN SHALL, AS A MINIMUM, MEET THE FOLLOWING STRUCTURAL DESIGN CRITERIA PER 2022 CALIFORNIA BUILDING CODE. SEE SPECIFICATION
13207 FOR ADDITIONAL DESIGN CRITERIA FOR THE TANK DESIGN:
a. ROOF LIVE LOAD : 40PSF (NON-REDUCIBLE) WITH A 300 LBS CONCENTRATED LOAD.
b. WIND DESIGN DATA:
i. BASIC DESIGN WIND SPEED, Vult (3-SEC GUST): 99 MPH
ii. EXPOSURE: C
c. EARTHQUAKE DESIGN DATA (ASCE 7-16):
i. RISK CATEGORY: IV
ii. SEISMIC IMPORTANCE FACTOR, Ie: 1.50
iii. DESIGN SPECTRAL RESPONSE ACCELERATION, SDS*: 1.673 g iv. DESIGN SPECTRAL RESPONSE ACCELERATION, SD1*: 0.799 g v. SEISMIC DESIGN CATEGORY: D
vi. RESPONSE MODIFICATION FACTOR, R: 3.25
(ANCHORED FLEXIBLE-BASE TANK)
vii. LONG-PERIOD TRANSITION PERIOD, TL: 8 SECONDS
* SITE-SPECIFIC GROUND MOTION HAZARD ANALYSIS PER ASCE
7-16 CHAPTER 21.2 METHOD 1.
d. GEOTECHNICAL DESIGN DATA:
i. ALLOWABLE GROSS BEARING PRESSURE 4500 PSF

4. INSPECTION OF REBAR BY ENGINEER REQUIRED PRIOR TO

PLACEMENT OF CONCRETE FOR PIPE ENCASEMENT (VERIFY MINIMUM

CONCRETE COVER AT TANK CONNECTION)

5. FOR WATERSTOP SEE DETAILS S106/TYP & S107/TYP. WATERSTOP SHALL BE CONTINUOUS WITH CLOSED LOOP ALL AROUND JOINTS.

6. PRIOR TO PLACING FILL, THE GEOTECHNICAL ENGINEER SHALL

REVIEW AND VERIFY THE BOTTOM OF ALL EXCAVATIONS ARE
SUITABLE FOR PLACING COMPACTED FILL.

CONCRETE

BACKFILL

AGGREGATE BASE COURSE

UNDISTURBED EARTH MATERIAL

SCARIFIED NATIVE MATERIAL
LEGEND:

1. PROVIDE VORTEX BREAKER AT OUTLET PIPE PER DETAIL 13/S07.

VORTEX BREAKER NOT REQUIRED AT INLET PIPE. INLET PIPE SHOWN.

2. LINER PER SECTION 02666. TERMINATE MEMBRANE LINER AT PIPE ENCASEMENT.

3. SCARIFY NATIVE MATERIAL. MOISTURE CONDITION TO AT LEAST 2% ABOVE OPTIMUM MOISTURE CONTENT AND RECOMPACT TO 95%
RELATIVE COMPACTION.
# KEY NOTES:

A B C D E G
(ALL AROUND)
TOC 255.00
L

ALL AROUND
LPT 299.60
2'-6"
SEE DETAIL 1 / -

FOR OMITTED

SUBGRADE

PREPARATION

INFORMATION

SLOPE SLOPE
SLOPE
SLOPE

SLOPE SLOPE
TYP
S184 6"W X 6"T

ALL AROUND
F
MAX WSE 292.00

FINISH SURFACE

SEE CIVIL DWGS
P
S06

SEE ELECTRICAL DWGS

FOR CONDUIT AND CABLE

PENETRATIONS AT ROOF
HPT 301.40
5 S05

AL GUARDRAIL

INTERIOR SST LADDER
-
1 ACCESS HATCH
TOC 255.00
T.O. CURB 300.10
FIN GR 262.00

AL LADDER WITH

LOCKING LOWER CAGE

CONCRETE WALL

FOOTING & SLAB

CONCRETE
WALL

ASSEMBLY
12" THICK ABC LEVELING

COURSE OVER COMPACTED
SUBGRADE COMPACTED TO 95%

RELATIVE COMPACTION NEAR

OPTIMUM MOISTURE CONTENT
PER ASTM D1557
30 MIL

MEMBRANE
LINER
12" CLASS 2
ABC SEE C03
4" AC PAVING
SEE C03
12" SCARIFIED NATIVE MATERIAL
NATIVE

SUBGRADE
MIN

ANCHORED
FLEXIBLEBASE

CONNECTION
4" PERFORATED

DRAIN PIPE/LEAK

DETECTION PIPE

FILTER FABRIC

BEGIN SLOPE

TO SWALE
1% SLOPE
3'-0"

FIN GRADE, SEE CIVIL DWGS
2'-0" MIN
6'-0"
TYP
S106 W/ WSTP
15 S08

SHEETING/SHORING AS REQUIRED

SAFE CONSTRUCTION
SLOPE
2 6 MIL POLYETHYLENE SHEETING

AT CONTRACTOR'S OPTION
255.00
1'-6"
1'-3"
1'-4"
INV 249.08

CRUSHED ROCK
5'-0"

FLOOR OF EXIST
RESERVOIR EL 257±
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN
DESIGNED JOB NO.

DRAWING NO.

SHEET NO.

VERIFY SCALES

IF NOT ONE INCH ON

THIS SHEET, ADJUST

SCALES ACCORDINGLY

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF
FILE NAME:
59 PLOT DATE:

SEPTEMBER 2025

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
201631
9/9/2025 11:13:42 PM
R:\d0163181\20163100S0801.rvt
S03

SKYVIEW RESERVOIR
SECTIONS AND DETAILS 1 22

STRUCTURAL
JAD
JBB
MAE
SCALE:

SECTION
S01 3/8" = 1'-0"
E
SCALE:

SECTION
S01 1/8" = 1'-0"
C
SCALE:

SECTION
S01 1/8" = 1'-0"
D
SCALE: - 1/2" = 1'-0"
1 DETAIL
Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:25:48-07'00'

Page 1473 of 1832 ends

OVERFLOW WEIR
TYP
S550 AL GRATING

SUPPORTS
3'-0" X 1'-6" REMOVABLE

GRATING SECTION
2 SEE NOTE
- 2
F
72"X72" PRECAST CATCH BASIN

W/ ALUMINUM GRATING PER
SECTION 02084 SEE CIVIL DWGS

FOR DRAIN CONTINUATION
3 CEMENT GROUT,
SLOPE 1% TO

OVERFLOW PIPE
TOC 255.00
4" SST FLG PIPE OUTLET
4" SST MPT BALL VALVE W/ BLIND FLANGE

ANCHORED FLEXIBLE-BASE

CONNECTION

CONCRETE WALL ASSEMBLY

INSTALL PIPE AT AN ELEVATION
WHERE A 2 DEGREE SLOPE FROM

VALVE TO RESERVOIR IS
MAINTAINED. COORDINATE WITH

ALTITUDE VALVE MANUFACTURER

FL X FL PIPE CAST INTO

WALL OR COUPLERS PER

TANK MANUFACTURER
15 S08
FIN GR 262.00
GENERAL NOTES:

1. FOR GENERAL STRUCTURAL NOTES, REFER TO DRAWING GS01.

2. CONTRACTOR SHALL DESIGN OVERFLOW WEIR. REFER TO SECTION 13207 FOR OVERFLOW WEIR DESIGN REQUIREMENTS.

3. ALL STAINLESS STEEL SHALL BE A MINIMUM OF 316/316L FOR WELDING FABRICATIONS UNLESS NOTED OTHERWISE.

4. AT CONTRACTOR'S OPTION, DECHLORINATION WEIR WALL MAY BE

PROVIDED AS PRECAST, AS PART OF THE PRECAST CATCH BASIN

WITH BOTTOM SLAB THICKNESS PER PRECAST DESIGN
SPECIFICATION.

5. SUBGRADE PREPARATION SIMILAR TO DETAIL 1/S03.

KEY NOTES:

1. GRATING SUPPORTS SIMILAR TO S550/TYP. COORDINATE WITH PRECAST BASIN MANUFACTURER.

2. DECHLORINATION WEIR WALL. SEE DETAIL FOR
REINFORCING.

3. BOTTOM SLAB OF PRECAST CATCH BASIN SHALL BE MINIMUM 12" THICK TO ALLOW FOR 8" EMBEDMENT FOR DOWELS FOR CAST-INPLACE DECHLORINATION WEIR WALL. #
7 S05
2'-0"
TOC 292.50
TOC 257.00

OVERFLOW WEIR

SST PIPE SUPPORT BRACING

DESIGNED BY TANK SUPPLIER (TYP)
MIN
7'-0"
12" SST BFV PROVIDE LOCK AND
CHAIN PER SECTION 15110

DUCKBILL

CHECK VALVE
4'-6"

REMOVABLE

BOLLARD
(BEYOND)

FIN GRADE

SEE CIVIL
DWGS
72"X72" PRECAST CATCH BASIN

W/ ALUMINUM GRATING PER
SECTION 02084 SEE CIVIL DWGS

FOR DRAIN CONTINUATION
1'-6"
2 TYP
AL GRATING S550

SUPPORTS
1 T.O. SUMP 254.83
LPT 254.93
1% MIN FROM LPT

TO SUMP
3 15
S08

ANCHORED FLEXIBLE-BASE

CONNECTION
12" R
24" R

CEMENT GROUT,
SLOPE 1% TO

OVERFLOW PIPE
316 SST MESH

INSECT SCREEN
MIN
4'-0"
MIN
2'-0"
CL 270.91
CL 265.50
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN
DESIGNED JOB NO.

DRAWING NO.

SHEET NO.

VERIFY SCALES

IF NOT ONE INCH ON

THIS SHEET, ADJUST

SCALES ACCORDINGLY

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF
FILE NAME:
59 PLOT DATE:

SEPTEMBER 2025

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
201631
9/9/2
0 2
5 11:13:4
9 P
M
R:\d0163181\20163100S0801.rvt
S04

SKYVIEW RESERVOIR
SECTIONS AND DETAILS 2 23

STRUCTURAL
JAD
JBB
MAE
SCALE:

DETAIL
S01
1/4" = 1'-0"
2 SCALE:

SECTION
S01 3/8" = 1'-0"
G
SCALE: - 3/8" = 1'-0"

F SECTION
Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:26:04-07'00'

Page 1474 of 1832 ends

4'-10"
3'-0"
6" 6"
11' - 0"
15' - 0"

LOCKABLE

SECURITY
COVER
1/2" SST BALL
VALVE

PREFORMED

CHANNEL

PIPE SUPPORT,
6'-0" SPACING
(TYP)
K
-
TOC
1'-8"
1'-0" 4"
4"
1 1/2" 8" 3"

HEAVY DUTY

SST HINGE (TYP)
RD 7/8" DIA WITH

HOLE SIZED FOR

PADLOCK HASP

HANDLE BENT
RD 3/8" DIA
J
-
H
-
(TYP)
3"
2"

CUT SLOTS IN

TOP PLATE TO

ACCOMMODATE
PIPES

TANK WALL
1'-3"
6" 3"
1'-10"
10" 1'-2"
5" 8"
3/4"
R=1" (TYP)
4" DIA DRAIN HOLE

BENEATH EACH PIPE
9"
2'-0"

INSIDE OF

TANK WALL
1/2" SST BALL
VALVE
1 1/2" SCH 40

STL PIPE
1 1/2" NIPPLE
1 1/2" SCHEDULE 40 HALF

NPT THREADED CPLG

LOCKABLE

SECURITY
COVER
6"

CAST PIPE

PENETRATION

INTO WALL
GENERAL NOTES:

1. FOR GENERAL STRUCTURAL NOTES, REFER TO DRAWING GS01.

2. SECURITY ENCLOSURES:

A. SECURITY ENCLOSURES TO BE PROVIDED BY TANK
MANUFACTURER.

B. FABRICATE SECURITY ENCLOSURE FROM 3/8" SST PLATE.

C. GRIND ALL EDGES AND WELDS SMOOTH.

D. ROUND CORNERS AND EDGES TO 1/8" RADIUS.

E. PROVIDE HIGH STRENGTH PADLOCK.

F. SST HINGE SHALL PROVIDE 180° ROTATION.

G. REPAIR COATING ON RESERVOIR EXTERIOR AND INTERIOR
WHERE DAMAGED BY WELDING.

H. PROVIDE WITH TYPE 316/316L STAINLESS STEEL.

3. SEE SECTION 13207 FOR ADDITIONAL REQUIREMENTS.

STAINLESS STEEL

MANWAY GRAB BAR

CONC CORE WALL

INSIDE FACE OF WALL
GASKET

FIELD WELD

HAND WHEEL AND YOKE
CL
3/8" DIA HOLE

FOR PADLOCK

PADLOCKS
2 REQUIRED
3'-0" CLR

OPENING
3'-0" ABOVE FIN GR (TYP)

SHOTCRETE COVER

WALL COLLAR WELDED

TO SLEEVE CENTERED

WITHIN CONC CORE WALL,

THICKNESS PER TANK

MANUFACTURER

SST DISHED HEAD AND
SLEEVE

SST LADDER

EXTEND TO FLOOR

OF RESERVOIR
2'-0"

PRECAST CATCH BASIN

BOTTOM SLAB
6" DIA OPENING AT BOTTOM

CENTERED ON WALL (TYP)
TYP
S194 #5 DWLS W/
8" EMBED

SECTION
8" 3'-0" 8"
8" 1'-6"

PRECAST CATCH

BASIN WALL
6" DIA OPENING AT

BOTTOM CENTERED

ON WALL (TYP)
#5@8" EW VERT

CENTERED IN WALL
(TYP)
PLAN

BOTTOM SLAB OF PRECAST CATCH
BASIN SHALL BE MINIMUM 12" THICK
TO ALLOW FOR 8" EMBEDMENT FOR

DOWELS FOR CAST-IN-PLACE

DECHLORINATION WEIR WALL

SST BRACKET, J HOOK OR SIM
1'-0"
3/4" OD X 1/16" X 1" BAND

TACK WELDED TO BRACKET
(8) 5/8" X 1/4" FLAT BAR BRACKETS

BEND TOP AND BOTTOM OF ALL

BRACKETS EQUALLY SPACED
(8) 5/8" GALV CAP BOLTS TACK

WELD NUTS TO BRACKET
34" OD X 30" ID X 1/4" PL
34" OD X 1/4" X 8" LONG ROLLED PL
#5@12" (TYP)
#5 (TYP)

RESERVOIR
CL
(8) 5/8" GALV CAP BOLTS TACK

WELD NUTS TO BRACKETS

NEOPRENE WASHER
2X2 MESH BRONZE, BRASS OR

MONEL METAL WIRE-CLOTH
SCREEN, 20 GA (0.035") WIRE AND
#14 MESH SS NON CORRODIBLE

INSECT SCREEN (BEND SCREEN
1" ALL AROUND TOP & BOT
1/4" ROLLED PL
5/8" ANCHOR BOLT (DOUBLE NUT

FOR LEVELING) EQUALLY
SPACED ALL AROUND (12 TOTAL)
3'-10"
3'-10" SQ CURB W/ 2'-6"

DIA OPENING IN CENTER
48" DIA X 3/16"

BUMPED HEAD
PLAN

SECTION
CL
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN
DESIGNED JOB NO.

DRAWING NO.

SHEET NO.

VERIFY SCALES

IF NOT ONE INCH ON

THIS SHEET, ADJUST

SCALES ACCORDINGLY

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF
FILE NAME:
59 PLOT DATE:

SEPTEMBER 2025

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
201631
9/9/2025 11:13:53 PM
R:\d0163181\20163100S0801.rvt
S05

SKYVIEW RESERVOIR
SECTIONS AND DETAILS 3 24

STRUCTURAL
JAD
JBB
MAE
SCALE:

DETAIL
S01 1" = 1'-0"
3 WATER SAMPLING STATION
SCALE:

DETAIL
S01 1" = 1'-0"
4 WATER SAMPLING STATION
SCALE: - 1" = 1'-0"

J SECTION
SCALE: - 1" = 1'-0"

H SECTION
SCALE: - 1" = 1'-0"

K SECTION
SCALE:

DETAIL
S01
1" = 1'-0"
6 MANWAY
SCALE:

DETAIL
1" = 1'-0"
7 SCALE:

DETAIL
S02 1/2" = 1'-0"
5 ROOF VENT
S04
Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:26:25-07'00'

Page 1475 of 1832 ends

L
-
M
-
N
-
8 S01
DETAIL

NO SCALE
201631S0401
L
-

SECTION

NO SCALE
201631S0401
M
-

SECTION

NO SCALE
201631S0401
9 S01
DETAIL

NO SCALE
201631S0401
N
S08

SECTION

NO SCALE
201631S0401

2.5 "
M
IN
10 S08
DETAIL

NO SCALE
201631S0401
P
S03

SECTION

NO SCALE
201631S0401
6"
31/2
"

CENTERED ON COREWALL
3" WIDE BEARING PAD
1/2
"
4"
9"
11 -
DETAIL

NO SCALE
201631S0401
MAE
JBB
JAD
S06
25 STRUCTURAL

SKYVIEW RESERVOIR
SECTIONS AND DETAILS 4
201631-100000 201631S06.dgn
JB
aum
barger

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

2. SEE SECTION 13207 FOR ADDITIONAL REQUIREMENTS.

1. FOR GENERAL STRUCTURAL NOTES, REFER TO DRAWING GS01.

GENERAL NOTES:

SEISMIC CABLE SLEEVE (TYP)
1/4" THICK PLASTIC SHIM UNDER

EVERY REINF BAR LEG
W
ALL
FO
O
TIN
G
W
ALL
7-WIRE GALVANIZED

SEISMIC CABLE SLEEVE

PRESTRESSING

STRAND (TYP)

CL OF ANCHOR
CABLE SLEEVE.

OF CLOSED CELL

NEOPRENE GLUED

TOGETHER WITH
NEOPRENE GLUE.

CLOSED CELL
GALV STRAND.
(TYP)

PER TANK CONTRACTOR

PRESTRESSING STRAND
(TYP)

CL OF VERTICAL THREAD BAR ASSEMBLY

TYPICAL SLAB REINFORCING

PLACE DIRECTLY BENEATH
#4 HOOPS WITH LAP SPLICE.

UNDER COLUMN

RECESS CENTERED

COLUMN FOOTING
(TYP)

PLASTIC SPACER DISC

COLUMN FOOTING ABOVE
2" CLR
6"

TANK CONTRACTOR

VERTICAL BARS PER

TANK CONTRACTOR
SPIRAL REINF + PITCH PER

CONTRACTOR

DIA PER TANK
SURFACE. SEE NOTE 1

ROUGHEN CONCRETE
COLUMN FOOTING.

COMPOUNDS BY SANDBLASTING, OR EQUAL, PRIOR TO CONCRETE PLACEMENT FOR THE

1. COLUMN FOOTING RECESSES SHALL BE ROUGHENED AND CLEANED OF CURING NOTES:

DIMENSION EQUAL TO HALF THE SPACING

ELEVATION
W
ALL
VERTICAL WALL CONSTRUCTION JOINT. TWO

OF THE SEISMIC CABLES AT THE WALL

JOINT MAY BE BENT BACK SO THAT THEY DO

NOT INTERFERE WITH THE WALL CONSTRUCTION
JOINT. (TYP)
CL
W
ALL
FO
O
TIN
G

OF THE VERTICAL THREAD BAR ASSEMBLIES

3. SPACE WALL CONSTRUCTION JOINTS EQUALLY.

2. WALL AND FOOTING REINFORCEMENT NOT SHOWN FOR CLARITY.

1. DIMENSIONS MEASURED AT CENTER OF WALL.

NOTES:
40 DUROMETER SOLID

PVC REGLET

SHOTCRETE AND

WRAPPED STRAND

NEOPRENE PAD
NEOPRENE BEARING PAD.

PLACE CONTINUOUSLY

BETWEEN SQUARE TUBING

AFTER PLACING ROOF CONC

AND BEFORE APPLICATION

OF SHOTCRETE
3/4" DRIP GROOVE

REINFORCING NOT SHOWN

FOR CLARITY

SHOWN FOR CLARITY

REINFORCING NOT
ROOF SLAB. ROOF
RUBATEX R423N (OR EQUAL)

UNDER SIDE OF ROOF
NEOPRENE PAD. GLUE TO

THREAD BARS AND WALL
CONC COREWALL. VERTICAL

CLOSED CELL RUBBER

RUBBER SEISMIC

USE TWO PIECES

CLOSED-CELL RUBBER
BASE OF COLUMN.
2" CLR (TYP)

ROUGHEN CONC SURFACE
TO 1/4" AMPLITUDE.

ENCLOSING IN FORM.

THOROUGHLY AFTER FABRICATION AND BEFORE
SPIRAL. INSPECT COLUMN REINFORCING

ALL TIE WIRES MUST BE BENT ENTIRELY WITHIN
PRIOR TO USE.

SPACERS MUST BE DEMONSTRATED
PLACING OPERATIONS. ADEQUACY OF

FABRICATION, ERECTION, AND CONCRETE

PROPER COVER DURING THE ENTIRE

REINFORCING IN PLACE AND TO MAINTAIN

SIZE, STRENGTH, AND SPACING TO HOLD

PLASTIC SPACER DISC MUST BE OF SUFFICIENT
ROWS AT 36" MAXIMUM VERTICAL SPACING.

TOP AND BOTTOM. PLACE HORIZONTAL
SPACERS AT 60° HORIZONTALLY. START AT
HIGH STRENGTH PLASTIC SPACER DISC. USE
TO 1/4" AMPLITUDE

ROUGHEN CONC SURFACE

ONE FULL REVOLUTION

SPIRAL REINFORCING

LAP SPLICE

TYP SLAB REINF

VERTICAL BARS

FOOTING TO COLUMN

SPLICE BARS FROM

VERTICAL BARS OR LAP

USE CONTINUOUS

CONTRACTOR

PER TANK
SLAB ROOF. REINF

TWO-WAY FLAT
PANEL

HOOK (TYP)
3/4" KEY
1" KEY
DROP
SURFACE TO 1/4" AMPLITUDE.

RECESS. ROUGHEN CONC
1 1/2" DEEP FOOTING

ADD BARS PER TANK CONTRACTOR

CONC FOOTING

FLOOR SLAB
CONC

SEISMIC WALL ANCHOR (TYP)
SEE SECTIONS Q/S07 AND S/S07

FOR THREADED BAR ASSEMBLY
SEE DETAIL 09/S06 AND DETAIL 10/S06
S/S07

SEE SECTION

CONTRACTOR

PER TANK

BAR ASSEMBLY

VERT THREAD
6"
45°
SCALE:

FILE:

COLUMN/FOOTING
SCALE:

FILE:

COLUMN
SCALE:

FILE:

FOOTING/RECESS
SCALE:

FILE:

SEISMIC WALL ANCHOR
SCALE:

FILE:

SEISMIC WALL ANCHOR
SCALE:

FILE:

ELEVATION OF SEISMIC CABLES IN COREWALL
SCALE:

FILE:

ROOF TO WALL JOINT
SCALE:

FILE:

VERTICAL WALL CONSTRUCTION JOINT
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:26:44-07'00'

Page 1476 of 1832 ends

S02
12 NO SCALE
201631S0401
R
- NO SCALE
201631S0401
S
S06 NO SCALE
201631S0401
T
- NO SCALE
201631S0401
S03
13 NO SCALE
201631S0401
Q
S06 NO SCALE
201631S0401
T
-
13/4
"
5" 5"
2 "
3 "
3 "
2 1/2" 2 1/4"
42 "
5 "
42"
1'-6"
MAE
JBB
JAD
S07
26 STRUCTURAL

SKYVIEW RESERVOIR
SECTIONS AND DETAILS 5
201631-100000 201631S07.dgn
ALaico
S
-
3 "

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

2. SEE SECTION 13207 FOR ADDITIONAL REQUIREMENTS.

1. FOR GENERAL STRUCTURAL NOTES, REFER TO DRAWING GS01.

GENERAL NOTES:
1/8 STEEL PIPE

PVC ADAPTER

STEEL PIPE

STEEL TEE

PVC ADAPTER

TOP BEARING PLATE

BEARING PLATES)

TOP AND BOTTOM

BOTTOM BEARING PLATE

COREWALL

STEEL PIPE
1/8

CL COREWALL
VALVE FOR GROUT PUMPING.

EPOXY GROUT FILL

PVC PIPE

PER TANK CONTRACTOR

VERTICAL THREAD BAR

CONC ROOF SLAB

BEARING PLATES)
(TYP TOP AND BOTTOM

SHAPED BEARING SURFACE
ANCHOR NUT W/ SPHERICALREQUIRED.

DOWELS. TWO

TANK RADIAL LINE

INSIDE FACE OF WALL

FILL ALL VOIDS BETWEEN

RECTANGULAR AND SQUARE
NEOPRENE PAD. FIT TIGHTLY AROUND
OF RECTANGULAR TUBING.

CL COREWALL

THREADBAR ASSEMBLY
BAR ASSEMBLY.

THREAD BAR ASSEMBLY BEFORE PLACEMENT
1/2" x 3" x 40 DUROMETER NEOPRENE
BEARING PAD. PLACE CONTINUOUSLY

AND FIT TIGHTLY AROUND THREAD BAR

ASSEMBLY BEFORE PLACEMENT OF
RECTANGULAR TUBING.

3. VERIFY ALIGNMENT AND CLEARANCES DURING WALL CONC PLACEMENT.

2. FILL ALL VOIDS BETWEEN WATERSTOP, ROOF PADS, AND TUBING WITH A SOFT MASTIC.

1. GLUE ALL PADS TO TOP OF WALL WITH CONTACT CEMENT.

NOTES:

HSS 8 x 6

CENTER OVER THREAD

TUBING WITH
RUBATEX R423N NEOPRENE

CL COREWALL

TANK RADIAL LINE
HSS 5 x 5

VERTICAL THREAD BAR

HOLE THROUGH BEARING
PLATE WITH 70° COUNTERSINK

BEARING PLATE
1 3/4" x 5" x 6"
(TYP TOP AND BOTTOM
(TYP TOP AND BOTTOM BEARING
(TOP BEARING PLATE ONLY)
PLATE)

BEARING PLATE)
FORM. WELD TO HSS.

SUPPORT IN WALL
1/2" NUT FOR

1. SPHERICAL ANCHOR NUT AND EPOXY GROUT FILL NOT SHOWN FOR CLARITY.

NOTE:
1/2" THICK RUBATEX R423N
1/4
TYP
SST PLATE 1/2" x 4" x 6"

ANCHOR (TYP)
2 - 1/2"Ø SST CONC
(TYP 2 PLACES)

GRAB BAR
1'-6
"
3/4"Ø SST CONCRETE ANCHOR

ACCESS HATCH

SINGLE LEAF ALUMINUM

HATCH DRAIN
4" SCHED 40 SST PIPE

AROUND)
12" CURB (TYP ALL
4" SCHED 40 SST PIPE

AROUND TUBING

RUBBER ALL

CLOSED-CELL
1" INTO 4"Ø PIPES.

TOP SURFACE. EXTEND ENDS

CONSTRUCTION JOINT

VERTICAL WALL
9" CIRCUMFERENTIAL ADD #5 ON EACH SIDE OF

VERTICAL

THREAD BAR
(TYP)

LAP SPLICE WRAPPED STRAND

SHOTCRETE AND

WATERSTOP AT WALL
BASE JOINT. CONNECT
TO 6" WATERSTOP IN

VERTICAL WALL JOINT

INSIDE FACE OF WALL

SPACING (TYP)

ASSEMBLY
1/2 THREAD BAR
OF WALL.

VERTICAL WALL CONST RUCTION
JOINT. ADD ONE EXTRA SET OF

HAIRPINS AT TOP AND BOTTOM

ASSEMBLY (TYP)
REINF

CIRCUMFERENTIAL
* = PER TANK CONTRACTOR
*
*
*

VERT REINF
6" WATERSTOP PER DETAIL S107/TYP
BAR 5/8" @ 6" OC
RING DIAMETER PIPE OD +3/4"
6" WIDE X 1/4" THK SST RING
PIPE
OUTLET
(TYP EA SIDE)

AND PHENOLIC WASHERS
SLEEVES, 316 SST NUTS,

SST BOLTS W/ PHENOLIC
(4) EVENLY SPACED 3/4" 316

TO OUTLET PIPE W/

SECURE VORTEX BREAKER

CERTIFIED EPOXY
RING W/ NSF 61

BOND TO STEEL
3/8" NEOPRENE PAD

TANK FLOOR

AFTER CUTTING
HSS 5 x 5 GALVANIZE
C
LR
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:
6" WIDE X 1/4" SST RING

IN EACH DIRECTION
W/ "T" CONFIGURATION
2" X 5/8" BARS @ 6" OC

SECTION
PLAN
3/16
3/16
3/16
3/16

(TYP)

(TYP)
BAR 5/8" BEYOND

TOP PLATE

GALVANIZED
PL 3/16
Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:27:01-07'00'

Page 1477 of 1832 ends

MAE
AL
JAD
S08
27 STRUCTURAL

SKYVIEW RESERVOIR
SECTIONS AND DETAILS 6
201631-100000 201631S08.dgn
JB
aum
barger
10 S06
N
S06
10 S06
N
S06
1/2" (TYP)

FLOOR CONSTRUCTION JOINT
201631S0401
S01 NO SCALE
14 WALL BASE JOINT
201631S0401
S03 NO SCALE
15 REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

2. SEE SECTION 13207 FOR ADDITIONAL REQUIREMENTS.

1. FOR GENERAL STRUCTURAL NOTES, REFER TO DRAWING GS01.

GENERAL NOTES:

PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

HOT-DIP GALV

PVC WATERSTOP
JOINT #5 x 5'-0"

CONSTRUCTION

CONCRETE FLOOR

1. SUBGRADE NOT SHOWN.

NOTES:

ANCHOR (TYP)

SEISMIC WALL

SEISMIC CABLES
SOFT MASTIC.

2. FILL ALL VOIDS BETWEEN BASE PADS, SEISMIC CABLE SLEEVE, AND WATERSTOP WITH A

1. SECURE ALL PADS TO TOP OF WALL FOOTING.

NOTES:

WATERSTOP

CONTINUOUSLY INSIDE
BEARING PAD. PLACE
DUROMETER 40 NEOPRENE
SEISMIC CABLE SLEEVE.

PREVENT GROUT LEAKAGE.

BETWEEN WALL FORMS TO
WALL. COMPRESS PADS

GREATER THAN WIDTH OF
WATERSTOP IS 1/2"

WIDTH OF BASE PADS AND
ABOVE TOP OF FOOTING.

PLACING COREWALL CONC

AND BEFORE APPLICATION
OF SHOTCRETE.

PAD. PLACE AFTER
RUBBER PAD. TOTAL

CLOSED-CELL

CLOSED-CELL RUBBER
PLACE TOP OF SLEEVE 3/4"
A A

TOP OF WALL FOOTING

INSIDE FACE OF WALL

CL WATERSTOP

CL SEISMIC WALL ANCHOR

ANCHOR (TYP)

SEISMIC WALL

A-A SECTION

INSIDE FACE OF WALL

CL WATERSTOP
WATERSTOP.

CONTINUOUSLY OUTSIDE

CLOSED-CELL
RUBBER PAD. PLACE
INSIDE WATERSTOP.

PLACE CONTINUOUSLY
NEOPRENE BEARING PAD.

DUROMETER 40

CAST-IN-PLACE CONCRETE

COREWALL REINFORCING BARS
PER TAN CONTRACTOR.

ON BOTH SIDES OF TOP EDGES
TIE OFF WATERSTOP AT 12" OC
9" WATERSTOP WITH CENTER BULB

TANK CONTRACTOR)

REINFORCING PER
(DIMENSIONS AND

CONCRETE SLIP PAD
Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:27:18-07'00'

Page 1478 of 1832 ends

FINISH SURFACE

SEE CIVIL DWGS
#8@10" OC EF (TYP)
T.O.W. 262.00
TYP
S140 W/WSTP
(TYP)
TYP
S592 HEAVY DUTY ACCESS HATCH
PER SPEC 08320
#7@10" EW T&B
TOC 248.00
2'-0"
#7@12" OC EF (TYP)
1 SEE MECH FOR PIPING

AND EQUIPMENT
TYP
MP544
TYP
(TYP) S180
TYP
W/WSTP S142
(TYP)
TYP
AC300AL LADDER

W/ SPRING
LOADED

SAFETY POLE
#8@10" EW T&B
2'-0"
5'-0"
TOC 247.78
GENERAL NOTES:

1. FOR GENERAL STRUCTURAL NOTES, REFER TO DRAWING GS01.

2. SUBGRADE PREPARATION SIMILAR TO DETAIL 1/S03.

3. ALL ACCESS HATCHES SHALL BE H-20 RATED AND MEET THE
REQUIREMENTS OF SPECIFICATION 08320.

4. GRATING LIVE LOAD = 100 PSF.

5. PIPING AND PIPE SUPPORTS NOT SHOWN FOR CLARITY. SEE
MECHANICAL DRAWINGS.

KEY NOTES:

1. 3M DBI-SALA FLUSH MOUNT DAVIT SLEEVE (8512828). SUBMIT

LOCATION TO ENGINEER FOR REVIEW AND APPROVAL BEFORE
INSTALLATION.

2. PROVIDE ALUMINUM GRATING SEAT PER S542/TYP. PROVIDE
MINIMUM (2) ANCHORS PER ANGLE.

3. COORDINATE FINAL ACCESS HATCH PLACEMENT WITH ENGINEER

BASED ON APPROVED SHOP DRAWING SUBMITTAL LAYOUTS FOR
VAULT PIPING AND VALVES. SEE MECHANICAL DRAWINGS.

4. CLEAR OPENING OF ACCESS HATCH SHALL BE AT LEAST 4" LARGER IN ALL DIRECTIONS THAN THE RESERVOIR CONTROL VALVE.

5. PROVIDE FALL PROTECTION GRATING SYSTEM AT ACCESS HATCH PER SPECIFICATION 08320.
#
W
-
X
-
5'-6" 6'-0" 5'-2" 3'-4" 2'-0"
22'-0"
3'-0" 6'-0" 1'-2" 4'-0" 2'-10"
17'-0"
1 HEAVY DUTY

ACCESS HATCH

REFER TO
SECTION 08320

COORDINATE

CONTROL POINT

SEE CIVIL DWGS

COORDINATE

CONTROL POINT

SEE CIVIL DWGS
3'-4"
2'-7"
3'-2"

BEAM REINFORCING,
(TYP)
4 (2) #8@10" ADD BARS T&B EACH

SIDE OF OPENING, ALTERNATE

WITH TYPICAL SLAB REINFORCING
5 TYP
S180 (TYP)
3 5
W
-
X
-
2'-0"
2'-0" 2'-0"
17'-0"
TYP
AC300AL LADDER
2'-6" 2'-0" 8'-6"
2'-0" 2'-6" 2'-0" 13'-6"
22'-0"
TYP
S542 AL GRATING

REBATES
TYP
S542
2 TYP
(TYP) S144 (TYP) 1'-0"
(TYP)
1'-0"

SUMP BEYOND
TYP
S592

HEAVY DUTY ACCESS

HATCH W/O LADDER PER
SPEC 08320 (TYP)
TYP
S140W/WSTP
(TYP)
2'-0"
TOC 248.00
T.O.W. 262.00

FOR SLAB REINF

SEE W/- (TYP)

FOR WALL REINF SEE W/-
(3) #8 T&B
#4 STIRRUPS @ 12" OC
5 1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN
DESIGNED JOB NO.

DRAWING NO.

SHEET NO.

VERIFY SCALES

IF NOT ONE INCH ON

THIS SHEET, ADJUST

SCALES ACCORDINGLY

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF
FILE NAME:
59 PLOT DATE:

SEPTEMBER 2025

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
201631
9/9/2025 11:13:59 PM
R:\d0163181\20163100S0801.rvt
S09

VALVE VAULT
PLANS AND SECTIONS 28

STRUCTURAL
JAD
JBB
MAE
SCALE:

SECTION
S09 3/8" = 1'-0"
W
SCALE:

ENLARGED PLAN
S01
3/8" = 1'-0"
V
UPPER
SCALE:

ENLARGED PLAN
S01 3/8" = 1'-0"
U

FOUNDATION
SCALE:

SECTION
S09
3/8" = 1'-0"
X
Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:27:33-07'00'

Page 1479 of 1832 ends

B
M02

SKYVIEW
RESERVOIR 2
(INLET)

CONNECTION TO
EXISTING 24"

INLET/OUTLET

PIPELINE
(OUTLET)
TYP
MA112
24" W
(TYP)
2'-0" MIN
24" W
12" R 24" R
3" PD
4'-0" 6'-3"
1 10
8 5 3
6 7 12
11 TYP
MP034 (TYP)
13 (TYP) 9
C
M02
4 1
14 2
4" W
15 (TYP)16
(TYP)16
24" SD
5 15
15 MOV-1
17 4" LDP
18 KEY NOTES:

1. 1.5" TAP CORP STOP AND 2" SAF-T-FLO INJECTION QUILL.

2. 24" ONE WAY PILOT CONTROLLED ALTITUDE VALVE (RESERVOIR CONTROL VALVE).

3. 24" RESTRAINED FLANGE COUPLING ADAPTER.

4. 24" DUAL FLAPPER CHECK VALVE (FLxFL).

5. 24" BFV WITH HANDWHEEL (FLxFL).

6. ACCESS LADDER WITH SAFETY POST EXTENSION.

7. 24" RESTRAINED DISMANTLING JOINT.

8. 24" BFV WITH MOTOR OPERATOR.

9. INSTALL TWO SELF-RESTRAINED DIP JOINTS SPACED AT 5 FEET.

JOINT NEAREST TO TANK OR STRUCTURE SHALL BE PLACED
1 FOOT FROM THE EDGE OF CONCRETE FOUNDATION OR PIPE
ENCASEMENT.

10. 1.5" TAP WITH INSULATING BUSHING TO 1.5" SST PIPE. CONNECT TO HOSE BIB PER DETAIL MA415/TYP. CONTRACTOR TO SUPPORT PIPING FROM TAP TO HOSE BIBB.

11. HOSE BIBB WITH WALL MOUNTED ROSE RACK PER DETAILS
MA415/TYP AND MA417/TYP.

12. SEE ELECTRICAL DRAWINGS FOR DUCT BANK PENETRATION
ROUTING.

13. SST MESH SCREEN (1/2"x1/2") AT FACE OF DUCT.

14. 14" SDR 26 HDPE DUCT TO EXHAUST FAN INVERT 255.0 AT STRUCTURE WALL.

15. INSULATING JOINT PER DETAIL 1/CP04 AT FLANGE NEAREST TO WALL.

16. INSTALL TWO FLEXIBLE RESTRAINED JOINTS SPACED AT 5 FEET.

JOINT NEAREST TO TANK OR STRUCTURE SHALL BE PLACED 1 FOOT FROM THE EDGE OF CONCRETE FOUNDATION OR ENCASEMENT.

17. LEAK DETECTION INSPECTION WELL. SEE DRAWING C04 AND DETAIL 2/C05.

18. 4" SDR 26 PVC WITHOUT PERFORATION. EXTEND 4" PIPING FROM INSPECTION WELL AND TERMINATE INTO VALVE VAULT.
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN
DESIGNED JOB NO.

DRAWING NO.

SHEET NO.

VERIFY SCALES

IF NOT ONE INCH ON

THIS SHEET, ADJUST

SCALES ACCORDINGLY

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF
FILE NAME:
59 PLOT DATE:

SEPTEMBER 2025

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
201631
9/9/2025 11:20:18 PM
R:\d0163192\20163100M0801.rvt
M01

VALVE VAULT
PLAN 29

MECHANICAL
DGB
JDW
NKM
SCALE:

PLAN A 3/8" = 1'-0"
Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:12:51-07'00'

Page 1480 of 1832 ends

CL 251.00

SKYVIEW
RESERVOIR 2

TANK WALL AND FOOTING
TYP
(TYP) MP544
3" PD
(TYP) 1
TYP
MP003
FG 262.00 +/-
2 3
4 5
TYP
8 MP034 (TYP)
8 (TYP) 9
4" W
1'-0"
4" SDR26 PVC

FROM INSPECTION WELL
KEY NOTES:

1. INSTALL TWO SELF-RESTRAINED DIP JOINTS SPACED AT
5 FEET. JOINT NEAREST TO TANK OR STRUCTURE SHALL
BE PLACED 1-FOOT FROM THE EDGE OF CONCRETE
FOUNDATION OR PIPE ENCASEMENT.

2. 3M DBI-SALA FLOOR MOUNT DAVIT SLEEVE, NO EQUAL. SEE
STRUCTURAL DRAWINGS FOR ADDITIONAL DETAILS.

3. 4" WYE STRAINER.

4. 4" BV WITH HANDWHEEL.

5. PRESSURE INDICATING TRANSMITTER (ROSEMOUNT, NO
EQUAL). SEE INSTRUMENTATION DRAWINGS FOR ADDITIONAL
INFORMATION.

6. TOP OF CURB SHALL BE LEVEL. TAPER CONCRETE CURB AS
REQUIRED.

7. PROVIDE BACK DRAFT DAMPERS WHERE SPECIFIED. INSTALL TO OPEN IN DIRECTION OF AIR FLOW.

8. INSULATING JOINT PER DETAIL 1/CP04.

9. INSTALL TWO FLEXIBLE RESTRAINED JOINTS SPACED AT 5 FEET.

JOINT NEAREST TO TANK OR STRUCTURE SHALL BE PLACED
1 FOOT FROM THE EDGE OF CONCRETE FOUNDATION OR
ENCASEMENT.
#
6" THICK CONCRETE PAD
W/ #4 @ 12" EW REINF
1/4" Ø TYPE
304 SST

BOLTS IN
FLUSH
SHELLS @ 12".
2 ANCHORS

MIN PER SIDE

SIZE AS INDICATED ON THE

DRAWINGS OR TO MATCH

EQUIPMENT SUPPLIED

RELIEF VENT,

CENTRIFUGAL ROOF

EXHAUSTER, OR
#4 @ 12" EW (TYP) SUPPLY FAN

BIRD SCREEN
6 6"
6" CURB
EG
EG + 0.1 FT
7 6" AGGREGATE BASE
3" PD
SP-1
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN
DESIGNED JOB NO.

DRAWING NO.

SHEET NO.

VERIFY SCALES

IF NOT ONE INCH ON

THIS SHEET, ADJUST

SCALES ACCORDINGLY

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF
FILE NAME:
59 PLOT DATE:

SEPTEMBER 2025

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
201631
9/9/2025 11:20:24 PM
R:\d0163192\20163100M0801.rvt
M02

VALVE VAULT
SECTIONS AND FAN DETAIL 30

MECHANICAL
DGB
JDW
NKM
SCALE:

SECTION
M01
3/8" = 1'-0"
B
SCALE:

DETAIL

NO SCALE
1 SUPPLY FAN FOR VALVE VAULT (FAN-1)
SCALE: C04

SECTION
M01 3/8" = 1'-0"
C
Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:12:37-07'00'

Page 1481 of 1832 ends

52 a
b
a
b
b
a
b
c
d
e
a
f
c
d
e
J
FACP
F
F
F
F
b
a
HP
c
b
a
d
e
a
b
a
b
ATP
SSM
*
b
B
A
b
c
a
a
b
SPD
b
a
a
b
b
a
b
a
b
a
b
a
a
b
a
b
a
c
ab
a
B
K
da
XXXX
X
c
b a
X
c
b a
X
b
a
EQUIP #
A
201631-100000 201631GE01.dgn
CE
CE
JGB
GE01
31 ELECTRICAL

ELECTRICAL LEGEND
B
R
oepken

ELECTRICAL PLAN SYMBOLS ELECTRICAL ONE-LINE SYMBOLS

DUPLEX RECEPTACLE

QUADRUPLEX RECEPTACLE
DUPLEX RECEPTACLE w/SPLIT WIRE

WELDING RECEPTACLE

SPECIAL PURPOSE RECEPTACLE

TWIST LOCK RECEPTACLE

TELEPHONE OUTLET

DATA COMMUNICATIONS OUTLET

LUMINAIRE IDENTIFICATION

LUMINAIRE, EMERGENCY/EXIT BATTERY-POWERED

LUMINAIRE, EMERGENCY BATTERY-POWERED REMOTE
(PERTAINS ONLY TO SHEET WHERE NOTE IS FOUND)

LUMINAIRE, EMERGENCY BATTERY-POWERED

LUMINAIRE, SURFACE OR PENDANT MOUNTED

LUMINAIRE, FLOOD/SPOT
LUMINAIRE, EXIT ONE OR TWO FACES AS INDICATED.

ARROW POINTS IN DIRECTION OF EGRESS.
2' X 2' LAY-IN TROFFER
2' X 4' LAY-IN TROFFER

LUMINAIRE POLE MOUNTED

PHOTOCELL
MOTOR

EQUIPMENT/INSTRUMENT LOCATOR

EXPOSED CONDUIT

EXPOSED CONDUIT HIDDEN BEHIND WALLS,

FLOORS OR OTHER STRUCTURES

UNDERGROUND CONDUIT, DIRECT BURIED

CONDUIT VERTICAL CHANGE IN DIRECTION

JUNCTION BOX

CONDUIT SEAL

MEDIUM VOLTAGE

DISCONNECT SWITCH

NON-FUSED CUT OUT

MEDIUM VOLTAGE

DISCONNECTING FUSE

SINGLE FUSE CUT OUT

MEDIUM VOLTAGE

DISCONNECTING FUSE

DOUBLE FUSE CUT OUT

MEDIUM VOLTAGE SINGLE FUSE

MEDIUM VOLTAGE DOUBLE FUSE

MEDIUM VOLTAGE
FUSE

LIVE FRONT TERMINATOR

MEDIUM VOLTAGE ELBOW

UTILITY METER

CAPACITOR

BATTERY

LIGHTNING ARRESTER
GROUND

AMPERE TEST POINT

VOLTAGE TEST POINT

GROUNDED WYE CONNECTION

DELTA CONNECTION

GROUND ROD

SOLID STATE

MULTIFUNCTION METER

GROUND ROD AND GROUND WELL

IDENTIFICATION SYMBOLS MEDIUM VOLTAGE LOW VOLTAGE MISCELLANEOUS

GROUNDING

LUMINAIRES

SWITCHES/RECEPTACLES RACEWAY

LUMINAIRE, WALL MOUNTED

CONDUIT IDENTIFICATION
XXXX = CONDUIT NUMBER,

REFER TO CONDUIT SCHEDULE

APPROXIMATE DIMENSIONS

EQUIPMENT ENCLOSURE

MOV-ELBOW ARRESTER

MEDIUM VOLTAGE CONTACTOR

MEDIUM VOLTAGE STARTER

KIRK KEY INTERLOCK
a
b
c

FIRE ALARM CONTROL PANEL

FIRE ALARM PULL STATION

FIRE ALARM HORN/STROBE COMBINATION

FIRE ALARM STROBE

CONDUIT SIZE AND CONDUCTORS

IN FLOOR QUADRUPLEX RECEPTACLE

IN FLOOR DUPLEX RECEPTACLE

ENGINE-GENERATOR RATINGS AS INDICATED ON

THE DRAWINGS

CURRENT TRANSFORMER WITH

SHORTING TERMINAL BLOCK

DISCONNECT SWITCH

LOW VOLTAGE CIRCUIT BREAKER

AUXILIARY OPERATOR
* = S = SHUNT TRIP
= G = GROUND FAULT INTERRUPTER
= V = SOLENOID KEY RELEASE

CIRCUIT BREAKER, MEDIUM VOLTAGE

ANSI RELAY DEVICE
~
G
VTP

CONDUIT IN SLAB

DRAWOUT CONNECTION
f
g
h

TRANSFORMER
a = DEVICE I.D.
b = KVA RATING
c = NUMBER OF PHASES
d = PRIMARY VOLTAGE
e = SECONDARY VOLTAGE
f,g= CONNECTION TYPE SYMBOL
h = IMPEDANCE

PACKAGED EQUIPMENT

LOAD RATING AS INDICATED
c d

POTENTIAL TRANSFORMER
a = QUANTITY
b = RATIO
c,d = CONNECTION TYPE SYMBOL
2 = DOUBLE POLE SWITCH
3 = THREE-WAY SWITCH
4 = FOUR-WAY SWITCH
K = KEY OPERATED SWITCH
F = SWITCH AND FUSESTAT HOLDER
P = SWITCH AND PILOT LIGHT
T = THERMOSTAT
D = DIMMER SWITCH
L = LOW VOLTAGE LIGHT SWITCH
M = MANUAL MOTOR STARTER

SINGLE POLE SWITCH
a
b = DEVICE SWITCHED DESIGNATION
= CIRCUIT DESIGNATION

SWITCH AND SINGLE RECEPTACLE

DISCONNECT SWITCH

SMOKE DETECTOR
= TYPE
= IONIZATION
= PHOTOELECTRIC
= DUCT DETECTOR

FIRE SPRINKLER
F = FLOW SWITCH
T = TAMPER SWITCH

LOW VOLTAGE CIRCUIT BREAKER

COMBINATION STARTER

WITH CONTROL POWER TRANSFORMER

SURGE PROTECTIVE
DEVICE

UNDERGROUND GROUND CABLE
PE

LOAD BANK

CONDUIT CAP

CONDUIT TEE
ARE LABELED LEFT TO RIGHT OR TOP TO BOTTOM.

BREAK AND CONTINUATION IN CONDUIT RUN

MEDIUM VOLTAGE TEE

FIRE ALARM

INDICATES KEYNOTE X

EQUIPMENT AND INSTRUMENT IDENTIFICATION
#4/0 SDBC UNLESS OTHERWISE NOTED

UNLESS OTHERWISE NOTED, GROUPED CONDUITS
d
R H
3P= THREE POSITION SWITCH

OCCUPANCY SENSOR

R G GO/NO-GO PANEL - SOLID

R GO/NO-GO PANEL - STROBE
c = TYPE

REFER TO ABBREVIATIONS LEGEND

OR IN DUCT BANK

DUCT BANK

SHOWN ON DUCT BANK SECTIONS

GO/NO-GO PANEL - STROBE AND HORN
= CIRCUIT DESIGNATION
= DEVICE SWITCHED FROM
= MOUNTING HEIGHT IN FEET TO

BOTTOM OF FIXTURE
FOR ALL OTHER DESIGNATIONS.

A = TYPE, REFER TO DISCONNECT SCHEDULE
= REFERENCE LIGHTING CONTROL COMPONENT SCHEDULE
= CIRCUIT DESIGNATION
= DEVICE SWITCHED DESIGNATION
= MOUNTING HEIGHT IN FEET TO BOTTOM OF SENSOR
X
a
b
c
= CIRCUIT DESIGNATION
b = DEVICE TYPE DESIGNATION
a
= CIRCUIT DESIGNATION
b
a
= DISCONNECT TYPE
a = AMP RATING
= CIRCUIT DESIGNATION
b
a
= MOUNTING HEIGHT
= CIRCUIT DESIGNATION
b
a
= MOUNTING HEIGHT
d
P
I
a
= CIRCUIT BREAKER NUMBER
= FRAME SIZE
= ANSI DEVICE FUNCTION
= QUANTITY
b
a
a
b

TYPE AS NOTED

FUSED DISCONNECT SWITCH
MCP = MOTOR CIRCUIT PROTECTOR
TM = THERMAL MAGNETIC
SS = SOLID STATE

FRAME SIZE UNLESS INDICATED)
(AT = AMP TRIP)
(AC = MCP CONTINUOUS RATING)
a = TYPE
b = FRAME SIZE (MANUFACTURER TO DETERMINE
c = NUMBER OF POLES
d = TRIP SETTING
e = DESIGNATION
f = INTERRUPTING RATING
A = TYPE, REFER TO DISCONNECT SCHEDULE
b = FUSE RATING
B = TYPE, REFER TO DISCONNECT SCHEDULE
a = CIRCUIT BREAKER DISCONNECT,
b = STARTER TYPE
c = NEMA STARTER SIZE
d = OVERLOAD

FULL LOAD AMPS AS NOTED
HP = HORSEPOWER RATING
a = RATED LOAD
b = UNIT(HP, KW, KVA) AS INDICATED
a = QUANTITY
b = RATIO
a = KVA/KW
b = VOLTAGE/CONNECTION
c = PHASE
d = WIRE
e = PF
a
MOTOR STARTER/DRIVES:
b
c
a = DEVICE TYPE
b
c

LINEAR FIXTURE
N = NETWORKED SINGLE OR

MULTIPLE SWITCH LOCATIONS
R = RED LIGHT
G = GREEN LIGHT
H = HORN
= INPUT OPTIONS
= OUTPUT OPTIONS
VFD-6 = 6-PULSE VFD
VFD-18 = 18-PULSE VFD
RVSS = REDUCED VOLTAGE SOLID

STATE STARTER
=
=

RVAT REDUCED VOLTAGE AUTO

TRANSFORMER
a/B DEVICE WITH BYPASS
STARTER. REFER TO

THE SPECIFICATIONS
=
=
=
DV/DT = Dv/dt FILTER
=

LL LINE REACTOR

PHF PASSIVE HARMONIC FILTER

LR LOAD REACTOR

SWF SINE WAVE FILTER
FOR STARTER DEFINITIONS.

REFER TO THE SPECIFICATIONS
X

LUMINAIRE SCHEDULE
= LUMINAIRE TYPE, REFER TO THE
VFD-RH = REDUCED HARMONIC VFD
(18-PULSE OR ACTIVE FRONT END

AS DEFINED IN THE SPECIFICATIONS)

DEDICATED RECEPTACLE
CAMERA

FIBER OPTIC CABLES
N = NUMBER OF INDIVIDUAL FIBERS
FO/N

INDIVIDUAL CONDUCTORS
U = NUMBER OF PARALLEL RUNS
U{3-X (Ø) & 1-X (G)}
(G) = DESIGNATES GROUND CONDUCTORS
Z = SIZE OF CONDUCTORS
1 = QUANTITY
1-Z (G) (WHERE INDICATED):
(N) = DESIGNATES NEUTRAL CONDUCTORS
Y = SIZE OF CONDUCTORS
1 = QUANTITY
1-Y (N) (WHERE INDICATED):
(Ø) = DESIGNATES PHASE CONDUCTORS
X = SIZE OF CONDUCTORS
3 = QUANTITY
3-X (Ø):

W"C (WHERE INDICATED): W = CONDUIT TRADE SIZE
W"C-(3-X (Ø), 1-Y (N) & 1-Z (G))

MULTI CONDUCTOR CABLES
X = SIZE OF CONDUCTORS
N/C = NUMBER OF PHASE CONDUCTORS IN THE CABLE
MC = MULTICONDUCTOR CABLE
U = NUMBER OF PARALLEL RUNS
U{[N/C-X (Ø) & INTEGRAL (G)]:MC}

TWISTED SHIELDED TRIPLETS
3/C#16S = THREE CONDUCTOR, 16 GAUGE,
K (WHERE INDICATED) = NUMBER OF TRIPLETS
K/3/C#16S

TWISTED SHIELDED PAIR
2/C#16S = TWO CONDUCTOR, 16 GAUGE,
K (WHERE INDICATED) = NUMBER OF PAIRS
K/2/C#16S

VFD CONDUCTORS
VFD = VFD CABLE
X = SIZE OF CONDUCTORS
N/C = NUMBER OF PHASE CONDUCTORS IN CABLE
U = NUMBER OF PARALLEL RUNS
U{[N/C-X (Ø) & INTEGRAL (G)]:VFD}

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
P
lotD
ate: 9-S
E
P
-2025 10:56:49
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1 LA
S
T
S
AVED
B
Y:

PROJECT NO. FILE NAME:

Digitally signed by John G. Briones
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.11 15:32:58-07'00'

Page 1482 of 1832 ends

CE
CE
JGB
GE02
32 ELECTRICAL

ELECTRICAL ABBREVIATIONS
201631-100000 201631GE02.dgn
B
R
oepken

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

ABBREVIATIONS
NOTES:
94 TRIPPING OR TRIP-FREE RELAY
93 FIELD-CHANGING CONTACTOR
92 VOLTAGE AND POWER DIRECTIONAL RELAY
91 VOLTAGE DIRECTIONAL RELAY
90 REGULATING DEVICE
89 LINE SWITCH
88 AUXILIARY MOTOR OR MOTOR GENERATOR
87 DIFFERENTIAL PROTECTIVE RELAY
86 LOCKOUT RELAY
85 PILOT COMMUNICATIONS, CARRIER OR PILOT-WIRE RELAY
84 OPERATING MECHANISM
83 AUTOMATIC SELECTIVE CONTROL OR TRANSFER RELAY

P PHASE PROTECTION

V VOLTAGE

T TRANSFORMER PROTECTION
(RELAY COIL CONNECTED IN RESIDUAL CT CIRCUIT)

N GROUND FAULT PROTECTION

M MOTOR PROTECTION

L LINE PROTECTION
(RELAY CT IN TOROIDAL OR GROUND SENSOR TYPE)

GS GROUND FAULT PROTECTION
(RELAY CT IN A SYSTEM NEUTRAL CIRCUIT OR GENERATOR PROTECTION)

G GROUND FAULT PROTECTION

B BUS PROTECTION

A ALARM ONLY

ABBREVIATIONS

POWER DEVICE FUNCTION NUMBERS

POWER DEVICE FUNCTION NUMBERS

COMMONLY USED SUFFIX LETTERS APPLIED TO

SYM SYMMETRICAL

SWGR SWITCHGEAR

SWBD SWITCHBOARD

SW SWITCH

STB SHORTING TERMINAL BLOCK

SS SOLID STATE

SPKR SPEAKER

SPST SINGLE POLE SINGLE THROW

SPDT SINGLE POLE DOUBLE THROW

SPD SURGE PROTECTIVE DEVICE

SP SINGLE POLE

SM SURFACE MOUNTED

SLT SEALTIGHT LIQUIDTIGHT FLEXIBLE CONDUIT

SFL SUB FEED LUGS

SDBC SOFT DRAWN BARE COPPER

SC SHORT CIRCUIT

SA SURGE ARRESTER

S SHIELD / SHORT-TIME

RVSS REDUCED VOLTAGE SOLID STATE

RVNR REDUCED VOLTAGE NON-REVERSING

RVAT REDUCED VOLTAGE AUTO TRANSFORMER

RMS ROOT MEAN SQUARED

RF RADIO FREQUENCY

REV REVERSE

RECPT RECEPTACLE

RAC RIGID ALUMINUM CONDUIT

PWR POWER

PVC POLYVINYL CHLORIDE RIGID PLASTIC CONDUIT

PT POTENTIAL TRANSFORMER

PRI PRIMARY
PPX POWER PANEL NO. X

PNL PANEL

PH PHASE

PFR PHASE FAILURE RELAY

PFCC POWER FACTOR CORRECTION CAPACITOR

PF POWER FACTOR

PE PHOTOCELL

PCM PROCESS CONTROL MODULE

PCS PVC COATED GALVANIZED STEEL CONDUIT

PB PUSHBUTTON / PULL BOX

PA PUBLIC ADDRESS
P POLE

OL OVERLOAD RELAY

OH OVERHEAD

O OPEN OR OPENED

NP NAMEPLATE

NO NORMALLY OPEN

NL NIGHT LIGHT

NFC NONMETALLIC FLEXIBLE CONDUIT

NEC NATIONAL ELECTRICAL CODE

NC NORMALLY CLOSED

N NEUTRAL

MW MEGAWATT

MVS MEDIUM VOLTAGE SWITCH

MVA MEGAVOLT-AMPERES

MV MEGAVOLT

MTS MANUAL TRANSFER SWITCH
MTR-X MOTOR NO. X

MTO MANUAL THROW OVER

MSP MOTOR STARTING PANEL
MS-X MOTOR STARTER NO. X

MPR MOTOR PROTECTION RELAY

MOV METAL OXIDE VARISTOR

MOD MOTOR OPERATED DAMPER

MLO MAIN LUGS ONLY

MH MANHOLE / MOUNTING HEIGHT

MCP MOTOR CIRCUIT PROTECTOR
MCC - X MOTOR CONTROL CENTER NO. X

MCA MOTOR CIRCUIT AMPS

MA MILLIAMPERE
M-X MOTOR CONTROLLER NO. X

LVL LEVEL

LV LOW VOLTAGE

LTG LIGHTING
LP - X LIGHTING PANEL NO. X

LP LIGHT POLE

LL LEAD-LAG LOAD REACTOR
LCP- X LOCAL CONTROL PANEL NO. X

LC LIGHTING CONTACT OR

LBL LABEL

LA LIGHTNING ARRESTOR

L-G LINE-GROUND

L-B LINE-BUS

L LONG-TIME

KWH KILOWATT HOUR

KWD KILOWATT DEMAND

KW KILOWATT

KVAR KILOVAR (REACTANCE)

KVA KILOVOLT AMPERE

KV KILOVOLT

KA KILOAMP

K KEY INTERLOCK

J JUNCTION BOX
82 DC LOAD MEASURING RECLOSING RELAY
81 FREQUENCY RELAY
80 FLOW SWITCH
79 AC RECLOSING RELAY
78 PHASE-ANGLE MEASURING RELAY
77 TELEMETERING DEVICE
76 DC OVERCURRENT RELAY
75 POSITION CHANGING MECHANISM
74 ALARM RELAY
73 LOAD-RESISTOR CONTACTOR
72 DC CIRCUIT BREAKER
71 LIQUID LEVEL SWITCH
70 RHEOSTAT
69 PERMISSIVE CONTROL DEVICE
68 BLOCKING OR OUT OF STEP RELAY
67 AC DIRECTIONAL OVERCURRENT RELAY
66 NOTCHING OR JOGGING DEVICE
65 GOVERNOR
64 GROUND DETECTOR RELAY
63 PRESSURE SWITCH
62 TIME-DELAY STOPPING OR OPENING RELAY
61 DENSITY SWITCH OR SENSOR
60 VOLTAGE OR CURRENT BALANCE RELAY
59 OVERVOLTAGE RELAY
58 RECTIFICATION FAILURE RELAY
57 SHORT-CIRCUITING OR GROUNDING DEVICE
56 FIELD APPLICATION RELAY
55 POWER FACTOR RELAY
54 TURNING GEAR ENGAGING DEVICE
53 FIELD EXCITATION RELAY
52 AC CIRCUIT BREAKER
51 AC TIME OVERCURRENT RELAY
50 INSTANTANEOUS OVERCURRENT RELAY
49 MACHINE OR TRANSFORMER THERMAL RELAY
48 INCOMPLETE SEQUENCE RELAY
47 PHASE-BALANCE OR PHASE-SEQUENCE VOLTAGE RELAY
46 REVERSE-PHASE OR BALANCE CURRENT RELAY
45 ABNORMAL ATMOSPHERIC CONDITION MONITOR
44 UNIT SEQUENCE STARTING RELAY
43 MANUAL TRANSFER OR SELECTOR DEVICE
42 RUNNING CIRCUIT BREAKER
41 FIELD CIRCUIT BREAKER
40 FIELD RELAY
39 MECHANICAL CONDITION MONITOR
38 BEARING PROTECTIVE DEVICE
37 UNDERCURRENT OR UNDERPOWER RELAY
36 POLARITY DEVICE
35 BRUSH-OPERATING OR SLIP-RING SHORT-CIRCUITING DEVICE 34 MASTER SEQUENCE DEVICE
33 POSITION SWITCH
32 DIRECTIONAL POWER RELAY
31 SEPARATE EXCITATION DEVICE
30 ANNUNCIATOR RELAY
29 ISOLATING CONTACTOR
28 FLAME DETECTOR
27N GROUND FAULT UNDERVOLTAGE RELAY
27 UNDERVOLTAGE RELAY
26 APPARATUS THERMAL DEVICE
25 SYNCHRONIZING OR SYNCHRONISM-CHECK DEVICE
24 VOLTS PER HERTZ RELAY
23 TEMPERATURE CONTROL DEVICE
22 EQUALIZER CIRCUIT BREAKER
21 DISTANCE RELAY
20 ELECTRICALLY OPERATED VALVE
19 STARTING-TO-RUNNING TRANSITION CONTACTOR
18 ACCELERATING OR DECELERATING DEVICE
17 SHUNTING OR DISCHARGE SWITCH
16 DATA COMMUNICATIONS DEVICE
15 SPEED OR FREQUENCY MATCHING DEVICE
14 UNDER-SPEED DEVICE
13 SYNCHRONOUS-SPEED DEVICE
12 OVER-SPEED DEVICE
11 MULTIFUNCTION DEVICE
10 UNIT SEQUENCE SWITCH
9 REVERSING DEVICE
8 CONTROL POWER DISCONNECTING DEVICE
7 ANODE CIRCUIT BREAKER
6 STARTING CIRCUIT BREAKER
5 STOPPING DEVICE
4 MASTER CONTACTOR
3 CHECKING OR INTERLOCKING RELAY
2 TIME-DELAY STARTING OR CLOSING RELAY
1 MASTER ELEMENT

TCM - TRIP CIRCUIT MONITOR

SER - SEQUENCE OF EVENTS RECORDER

RTU - REMOTE TELEMETRY UNIT/REMOTE TERMINAL UNIT

RIO - REMOTE I/O DEVICE

PQM - POWER QUALITY MONITOR

PMU - PHASOR MEASUREMENT UNIT

PDC - PHASOR DATA CONCENTRATOR

MET - SUBSTATION METERING

LGC - SCHEME LOGIC

HST - HISTORIAN

HMI - HUMAN MACHINE INTERFACE

HIZ - HIGH IMPEDANCE FAULT DETECTOR

ENV - ENVIRONMENTAL DATA

DFR - DIGITAL FAULT RECORDER

DDR - DYNAMIC DISTURBANCE RECORDER

CLK - CLOCK OR TIMING SOURCE

AFD - ARC FLASH DETECTOR

1. REFER TO SPECIFICATIONS AND OTHER DRAWINGS FOR ADDITIONAL ABBREVIATIONS.

INTERCOM INTERCOMMUNICATION

INT INTERLOCK

INST INSTANTANEOUS

IMC INTERMEDIATE METAL CONDUIT

IJB INSTRUMENT JUNCTION BOX

IC INTERRUPTING CAPACITY

I INSTANTANEOUS / INTERMITTENT LOAD

HZ HERTZ

HVAC HEATING/VENTILATION/AIR CONDITIONING

HV HIGH VOLTAGE

HSTAT HUMIDISTAT

HR HOUR

HPS HIGH PRESSURE SODIUM

HP HORSEPOWER

HF HIGH FREQUENCY

H HOT-LEG

GFR GROUND FAULT RELAY

GFI GROUND FAULT INTERRUPTER (BREAKER)

GFCI GROUND FAULT CIRCUIT INTERRUPTER (RECEPTACLE)

GRC GALVANIZED STEEL RIGID CONDUIT

GEN GENERATOR

G GROUND / EQUIPMENT GROUND / GROUND FAULT

FWD FORWARD

FVR FULL VOLTAGE REVERSING

FVNR FULL VOLTAGE NON-REVERSING

FU SW FUSED SWITCH

FU FUSE

FREQ FREQUENCY

FRC FIBERGLASS RIGID CONDUIT

FO FIBER OPTIC

FLX FLEXIBLE CONDUIT

FLA FULL LOAD AMPS

FDR FEEDER

FACP FIRE ALARM CONTROL PANEL

FA FIRE ALARM

F SUB-FED

ETM ELAPSED TIME METER

EP EXPLOSION PROOF

ENT ELECTRICAL NON-METALLIC TUBING

ENG ENGINE

ENCL ENCLOSURE

EMT ELECTRICAL METALLIC TUBING

EM EMERGENCY

E/G EMERGENCY GENERATOR

DS DOOR SWITCH

DPST DOUBLE POLE SINGLE THROW

DPDT DOUBLE POLE DOUBLE THROW

DM DEMAND METER

DISC DISCONNECT SWITCH

DEMO DEMOLITION
DCU - X DISTRIBUTED CONTROL UNIT NO. X

DCS DISTRIBUTED CONTROL SYSTEM

DC DIRECT CURRENT

CW CLOCKWISE / COOL WHITE

CV CONTROL VALVE

CT CURRENT TRANSFORMER

CS CONTROL SWITCH

CR CONTROLLED RECEPTACLE

CPT CONTROL POWER TRANSFORMER

COMM COMMUNICATION

COM COMMON

COAX COAXIAL CABLE

CKT CIRCUIT

CCW COUNTER CLOCKWISE

CCTV CLOSED CIRCUIT TELEVISION

CB CIRCUIT BREAKER

C CONDUIT / CONTINUOUS LOAD

BRF BELOW RAISED FLOOR

BKR BREAKER

BHP BRAKE HORSEPOWER

BFG BELOW FINISHED GRADE

BAT BATTERY
B BELL

AWG AMERICAN WIRE GAGE

AUX AUXILIARY

AUTO XFMR AUTOMATIC TRANSFORMER

ATS AUTOMATIC TRANSFER SWITCH

ATP AMMETER TEST POINT

ATO AUTOMATIC THROW OVER

AT AMP TRIP

ASYM ASYMMETRICAL

AS AMMETER SWITCH

ARM ARMORED CABLE

APU AUXILIARY POWER UNIT

ANT ANTENNA

ANN ANNUNCIATOR

AM AMMETER

AIC AMP INTERRUPTING CAPACITY

AFC AUTOMATIC FREQUENCY CONTROL

AF AMP FRAME

ACTR ACTUATOR

ACK ACKNOWLEDGE

AC ALTERNATING CURRENT

ABS ABSOLUTE
A AMP

XFMR TRANSFORMER

WP WEATHER PROOF

WT WATER TIGHT

W WATT / WEST

VTP VOLTAGE TEST POINT

VT VOLTAGE TRANSFORMER

VS VOLTAGE SWITCH

VR VOLTAGE REGULATOR

VP VAPORPROOF

VM VOLTMETER

VHF VERY HIGH FREQUENCY

VFD VARIABLE FREQUENCY DRIVE

VCP VENDOR CONTROL PANEL

VAR VARMETER

VA VOLT AMPERE
V VOLT

UVR UNDER VOLTAGE RELAY

UPS UNINTERRUPTIBLE POWER SUPPLY

UNG UNGROUNDED

UHF ULTRA HIGH FREQUENCY

TSTAT THERMOSTAT
TS2W TWO SPEED SEPARATE WINDING
TS1W TWO SPEED CONSEQUENT POLE, ONE WINDING

TS TEMPERATURE SWITCH

TP TWISTED PAIR

TM THERMAL MAGNETIC

TJB TERMINAL JUNCTION BOX

TERM TERMINAL

TENV TOTALLY ENCLOSED NON-VENTILATED

TEFC TOTALLY ENCLOSED FAN COOLED

TE TOTALLY ENCLOSED

TD TEMPERATURE DETECTOR RELAY

TC THERMOCOUPLE / TIME CLOCK / TRAY CABLE

TB - X TERMINAL BLOCK - UNIT X

TACH TACHOMETER
P
lotD
ate: 9-S
E
P
-2025 10:56:40
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1 LA
S
T
S
AVED
B
Y:

PROJECT NO. FILE NAME:

Digitally signed by John G. Briones
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.11 15:33:38-07'00'

Page 1483 of 1832 ends

J
J
TM
100A
2-#3 (Q) & 1-#3 (N) & 1-#8

UTILITY TRANSFORMER PNL-MAIN
LP-1
FROM

UTILITY
2P
PNL-1
(E) LP-1
PROJECT NO.

LAST SAVED BY:

FILE NAME:

HR
QGS
JGB
E01
33 ELECTRICAL

ELECTRICAL SITE PLAN AND

OVERALL ONE-LINE DIAGRAM
201631E01.dwg
ALaico
201631-100000

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

SKYVIEW
RESERVOIR 2
G
E04
H
E04
E
E03
F
E03
20'0 10' 40'
CAM-1
CAM-2
ZS-10
ZS-11
ZS-12
N-410
N-405
N-400
L-200
C-203
C-207
C-205
C-209
X-200
2 TYP
EM032
TYP
EM107
(TYP)
A
E02
TYP
EA070
(TYP)
1 B
E02
C
E02
TYP
EM001
(TYP)
TYP
EM015
(TYP)
3 3
4 OVERALL ONE-LINE DIAGRAM
KEY NOTES:

1. SUPPORT CONDUITS ON CONCRETE TANK WITH PREFORMED CHANNEL.

2. DISCONNECT SWITCH SHALL BE RATED 30A, 600V, 1 POLE, WITH NEMA 4X ENCLOSURE.

3. REMOVE EXISTING SECURITY CAMERAS, ASSOCIATED CONDUCTORS AND EXPOSED CONDUITS. MOUNT NEW CAMERA ON THE LIGHT POLE AT THE SAME HEIGHT AS EXISTING CAMERA WAS MOUNTED PREVIOUSLY.

PROVIDE NEW CONDUITS AND CONDUCTORS FOR THE NEW CAMERA AS SHOWN HERE AND ACCORDING TO THE CONDUIT SCHEDULE.

4. INSTALL NEW PANELBOARD LP-1 INSIDE EXISTING PANEL PNL-1 ENCLOSURE. REFER TO PANELBOARD SCHEDULE FOR ENCLOSURE BUS RATING AND LOAD INFORMATION.

5. TRANSFORMER IS OWNED AND MAINTAINED BY THE UTILITY.

6. COORDINATE MIXER CONDUIT PENETRATION WITH THE ACCESS HATCH SUPPLIER.

7. CONNECT CONDUIT AND CONDUCTORS TO THE ACCESS HATCH
INTRUSION SWITCH.

8. CONNECT CONDUIT AND CONDUCTORS TO THE LADDER INTRUSION SWITCH.

9. MOUNT JUNCTION BOX ADJACENT TO THE CAMERA.

10. PROVIDE NEMA 4X JUNCTION BOX WITH TERMINAL STRIPS FOR TRANSITION FROM MIXER CABLE TO FIELD WIRING. SUPPORT JUNCTION BOX WITH PREFORMED CHANNEL ON TANK'S ROOF.

11. REMOVE EXISTING PANELBOARD AND ITS FEEDER CONDUCTORS. REFER TO PHOTO 1 AND PHOTO 2 ON DRAWING E03 FOR PANEL LOCATION, LOAD INFORMATION, AND ADDITIONAL DEMOLITION NOTES.
#
MIX-1
C-202
7 8
L-203
FAN-1
L-130
9 ZS-13
C-201
TYP
EM201
GENERAL NOTES:

1. PROVIDE PROVISIONS FOR SUPPORTING ELECTRICAL EQUIPMENT ON THE

TANK SUCH THAT WATER STORAGE TANK'S STRUCTURAL INTEGRITY IS NOT COMPROMISED. CONTRACTOR SHALL COORDINATE LOCATION AND TYPE OF

ALL ANCHORAGES USED TO SUPPORT ELECTRICAL EQUIPMENT ON THE STORAGE TANK WITH THE TANK SUPPLIER.

2. DUCT BANKS RISING FROM GROUND SHALL BE ACCORDING TO TYPICAL DETAIL EM020/TYP.
11 TYP
EM105
TYP
10 EM315
6 C-200
5 Digitally signed by John G. Briones
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.11 15:33:24-07'00'

Page 1484 of 1832 ends

HR
QGS
JGB
E02
34 ELECTRICAL

SECTIONS AND SCHEDULES
201631-100000 201631E02.dgn
B
R
oepken
1 1
1 2

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
PANEL LP-1 9/13/2023
LOCATION: PNL-1 CABINET NEMA: 1 PH A WEIGHTED VA 4441
VOLTS: 240/120 FEED: BOTTOM PH B WEIGHTED VA 5300
PHASE & WIRE: 1 PH 3W MTG. SURFACE
INTERRUPT: 18 KAIC BUS RATING: 100
OPTIONS: SPD MAIN: MLO EQUIP SIZING VA 10600
PANEL AMPS 44.2
I/C/S DESCRIPTION LOAD (VA) BKR CIR Ø CIR BKR LOAD (VA) DESCRIPTION I/C/S C PNL-1 DOOR LIGHTS 100 15A-1P 1 A 2 15A-1P 1176 SP-1 - VAULT SUMP PUMP C C VAULT AND GATE LIGHTS 300 15A-1P 3 B 4 15A-2P 400 SITE LIGHTING C C SITE GFI RECEPTACLES 360 15A-1P 5 A 6 400 C
I GATE-1 - SLIDE GATE 1 1200 15A-1P 7 B 8 15A-1P 864 FAN-1 - VAULT FAN C I GATE-2 - SLIDE GATE 2 1200 15A-1P 9 A 10 15A-1P 696 MOV-1 - 24" MOTORIZED VALVE I C MIX-1 - TANK MIXER 1176 15A-1P 11 B 12 15A-1P 540 VAULT AND GATE GFCI RECEPTACLES C SPARE 20A-1P 13 A 14 20A-1P SPARE
SPARE 20A-1P 15 B 16 20A-1P SPARE
SPARE 20A-1P 17 A 18 20A-1P SPARE
LUMINAIRE SCHEDULE 9/13/2023

ITEM DESCRIPTION MOUNTING LAMP LUMINAIRE SPECIFICATIONS

METHOD QUANTITY TYPE MANUFACTURER CATALOG VOLTS VA
A

CAST-ALUMINUM HOUSING WITH CORROSION-RESISTANT PAINT

SEALED GASKET FOR PROTECTION AGAINST MOISTURE AND DUST

FROSTED GLASS DIFFUSER FOR EVEN LIGHT DISTRIBUTION
OPERATING TEMPERATURE -40ºC TO 40ºC
600 LUMENS, 4000K CCT
WALL MOUNT N/A LED LITHONIA OLVTWM 120 15
B

RUGGED DIECAST ALUMINUM WITH CORROSION RESISTANT HOUSING TWISTLOCK PHOTOCONTROL FOR SOLID STATE (20 YEAR RATED LIFE) IP66, WIDE ROADWAY OPTICS AND RATED FOR -40°C / (-40°F) MINIMUM AMBIENT

VERTICAL TENON (VH) MOUNTING ARM
15400 LUMENS, 4000K CCT
GREY COLOR ANODIZED ALUMINUM LIGHT POLE, 12'-0" HIGH, 4" DIA WITH 2" VERTICAL TENON ADAPTER

MATCH EXISTING POLES
POLE
MOUNT
N/A LED LITHONIA MGLEDM P1 4OK MVOLT WR VH GRSD PCLL 120 105 S-103
(2")
X-100
(2")
X-105
(2")
C-350
(2")
X-300
(2")
L-107
(2")
L-120
(2")
C-110
(2")
L-203
(2")
C-209
(2")
X-200
(2")
L-310
(2")
L-320
(2")
L-305
(2")
C-315
(2")
Width: 1'-11"
Height: 1'-9"
Width: 1'-11"
Height: 1'-5"
Width: 1'-7"
Height: 1'-9"
Width: 1'-7"
Height: 1'-5"

A DUCT BANK SECTION B DUCT BANK SECTION C DUCT BANK SECTION D DUCT BANK SECTION E01, E03, E04 E01, E03 E01, E03 E03
P
lotD
ate: 9-S
E
P
-2025 10:56:45
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1 LA
S
T
S
AVED
B
Y:

PROJECT NO. FILE NAME:
#
AND LUMEN LEVEL AND PROVIDE NEW MATCHING LIGHT FIXTURE.

2. VERIFY EXISTING LIGHT FIXTURE FINISHED PAINT, LIGHTING COLOR,

1. RECONNECT EXISTING CIRCUITS TO THE NEW LIGHTING PANEL.

KEY NOTES:

Digitally signed by John G. Briones
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.11 15:32:44-07'00'

Page 1485 of 1832 ends

PROJECT NO.

LAST SAVED BY:

FILE NAME:

HR
QGS
JGB
E03
35 ELECTRICAL

ACCESS GATE AND ELECTRICAL

SERVICE PLANS
201631E03.dwg
ALaico
201631-100000

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
A
E02
PNL-1

PNL-MAIN
LP-1 L-310
C-350
L-320
X-300
L-203
C-209
X-200
C-110
L-107
S-103
X-105
L-120
X-100
B
E02
C
E02
HH-1
TYP
EM056
L-300
C-300
LP-1-12

GFCI-WP
LP-1-3
12'-0"
B
TYP
EL507
C-325
C-320
C-307
C
E02
D
E02
TYP
EM001
(TYP)
L-305
C-315
TYP
EM015
(TYP)
5 1
4 3
2 GENERAL NOTES:

KEY NOTES:

1. SEE DRAWING E01 FOR LOCATION OF FACILITY ON SITE PLAN.

2. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE ARE NOT
SHOWN. USE THE SAME MATERIALS FOR CONDUITS, FITTINGS,

ATTACHMENTS AND MOUNTING AS INDICATED FOR PROCESS
POWER AND CONTROL WITHIN THE SAME AREA.

3. 3-WIRE AND 4-WIRE CIRCUITS SHALL NOT BE USED FOR LIGHTING CIRCUITS. EACH CIRCUIT SHALL HAVE A DEDICATED NEUTRAL TO THE PANELBOARD.

4. SIZE LIGHTING AND RECEPTACLE RACEWAYS PER THE
REQUIREMENTS IN THE SPECIFICATIONS FOR CONDUIT FILL.

PROVIDE 3/4" MINIMUM CONDUIT SIZE.
#

1. INSTALL THE NEW LIGHTING PANELBOARD LP-1 INSIDE THE
EXISTING PANEL PNL-1 ENCLOSURE AS SHOWN.

2. CONDUIT IS FOR GATE LIGHT AND RECEPTACLE.

3. PRECAST CONCRETE HANDHOLE DIMENSIONS SHALL BE MINIMUM 3' L x 3' W x 3' H.

4. FIELD VERIFY NEW CONDUIT ENTRY TO PNL-1. PROVIDE PULL BOXES OR JUNCTION BOXES MOUNTED ON THE EXISTING PNL-1 TO

COMBINE CIRCUITS AND ACCOMMODATE FOR CONDUIT ENTRY IF
NEEDED.

5. EXPOSED CONDUIT SHALL BE TYPE SEALTIGHT-LIQUIDTIGHT
FLEXIBLE CONDUIT. SUPPORT CONDUIT ON THE GATE.

6. EQUIPMENT LOCATION SHALL BE FIELD VERIFIED AND SELECTED PER THE GATE OPERATOR MANUFACTURER RECOMMENDATION.

7. PROVIDE DOUBLE POLE SINGLE THROW (DPST) SWITCH AND
CONNECT VAULT LIGHTING AND FAN TO IT. SWITCH ENCLOSURE
SHALL BE NEMA 4X RATED AND WEATHER PROOF.

8. REFER TO DRAWING E01 FOR CONTINUATION OF THE CONDUIT ROUTING.

9. THIS PICTURE SHOWS APPROXIMATE LOCATION OF THE NEW
LIGHTING PANEL LP-1 INSIDE THE EXISTING PNL-1, AND DOES NOT

INCLUDE OTHER NEW WORKS SUCH AS CONDUIT ROUTINGS, DUCT
BANKS RISERS, AND FAN SWITCH.

10. INSTALL GATE OPERATOR AND SECURITY EQUIPMENT ACCORDING TO THE MANUFACTURER INSTRUCTION AND RECOMMENDATION.

11. FIELD VERIFY THAT THE EXISTING LOAD WILL REMAIN IN
COMMISSION AND PROTECT EXISTING CONDUCTORS FOR IT.

EXISTING CONDUCTORS SHALL CONNECT TO THE NEW CIRCUIT
BREAKER INSIDE NEW PANELBOARD LP-1 AS SHOWN IN THE
PANELBOARD SCHEDULE.

12. DEMOLISH EXPOSED CONDUITS AND CONDUCTORS FOR DEMO
EQUIPMENT.

CONTINUED ON
DWG E01

CONTINUED ON
DWG E01

CONTINUED ON
DWG E01

CONTINUED ON
DWG E01
L-125

UTILITY TRANSFORMER
6 10
10 C-308
GATE DETECTION LOOP 10
PHOTO
SCALE:

FILE:
1 --- NO SCALE
201631E03A.jpg

EXISTING TRANSFORMER AND PANEL
LP-1 1
PNL-1 (E)
(E) UTILITY TRANSFORMER
1 ---
L-130
TYP
EM015
LP-1-5GFCI-WP
TYP
EM202
8 9
7 L-133
L-325
C-360
S-105
N-410
8 HH-2 3
2 ---
PHOTO
SCALE:

FILE:
2 --- NO SCALE
201631E03A.jpg

DEMOLITION OF EXISTING PANELBOARD
1 11
11 11
12 12
12 12
L-050
TYP
EM015
(TYP)

PNL-MAIN (E)
SCALE:

FILE:

PLAN
20163100E0101
E 6" = 1'-0"

MAIN ELECTRICAL SERVICE
SCALE:

FILE:

PLAN
20163100E0101
F 3" = 1'-0"

ACCESS GATE
CARD-1
MAGLOCK-1 GATE-2
GATE-1
Digitally signed by John G. Briones
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.11 15:32:29-07'00'

Page 1486 of 1832 ends

LP-1-12

GFCI-WP
LP-1-12

GFCI-WP
J
A
a LP-1-3
8'-0"
A
a LP-1-3
8'-0"
#4/0 SDBC TYP
EG002
TYP
EG001
TYP
(TYP) EG101
4 4

CONTINUED ON
DWG E01
PIT-1
ZS-1
TYP
EM070
A
E02
TYP
EM001
ZS-2
ZS-3
C-103
C-105
C-100
S-100
C-107
TYP
(TYP) EA070
PB-1 1
3 CONTINUED ON
DWG E01
2 C-110
X-100
L-120
X-105
L-107
S-103
TYP
EM315
6 5
L-100
L-105
MOV-1
SP-1
GENERAL NOTES:

1. SEE DRAWING E01 FOR LOCATION OF FACILITY ON SITE PLAN.

2. CONDUIT ROUTING FOR LIGHTING AND RECEPTACLE ARE NOT
SHOWN. USE THE SAME MATERIALS FOR CONDUITS, FITTINGS,

ATTACHMENTS AND MOUNTING AS INDICATED FOR PROCESS POWER AND CONTROL WITHIN THE SAME AREA.

3. 3-WIRE AND 4-WIRE CIRCUITS SHALL NOT BE USED FOR LIGHTING CIRCUITS. EACH CIRCUIT SHALL HAVE A DEDICATED NEUTRAL TO THE PANELBOARD.

4. SIZE LIGHTING AND RECEPTACLE RACEWAYS PER THE
REQUIREMENTS IN THE SPECIFICATIONS FOR CONDUIT FILL. PROVIDE 3/4" MINIMUM CONDUIT SIZE.

5. ALL GROUNDING CONDUCTORS SHALL BE 4/0 SDBC UNLESS NOTED OTHERWISE. USE CONNECTIONS AND TESTING AS DESCRIBED IN THE SPECIFICATIONS UNLESS OTHERWISE NOTED.

KEY NOTES:

1. MOUNT ELECTRICAL PULL BOX ON THE WALL. PULL BOX ENCLOSURE SHALL BE RATED FOR NEMA 4X AND SIZED ACCORDING TO NEC.

2. PROVIDE NEMA 4X JUNCTION BOX WITH TERMINAL STRIPS FOR TRANSITION FROM SUMP PUMP CABLE TO FIELD WIRING. SUPPORT

JUNCTION BOX WITH PREFORMED CHANNEL ON VAULT'S CONCRETE WALL.

3. SUPPORT CONDUITS ON CONCRETE WALL OR CEILING WITH
PREFORMED CHANNEL.

4. RECEPTACLE MOUNTING HEIGHT SHALL BE MINIMUM 4 FEET FROM THE VAULT FINISHED GRADE.

5. MOUNT DISCONNECT SWITCH FOR MOV-1 INSIDE THE VAULT AND SUPPORT IT ON CONCRETE WALL WITH PREFORMED CHANNEL.

DISCONNECT SWITCH SHALL BE RATED 30A, 600V, 2 POLES, WITH NEMA 4X ENCLOSURE. PROVIDE LOCKABLE ROTARY SWITCH.

DISCONNECT SWITCH MOUNTING HEIGHT SHALL BE MINIMUM 4 FEET FROM THE VAULT FINISHED FLOOR.

6. MOUNT DISCONNECT SWITCH INSIDE THE VAULT AND SUPPORT IT ON CONCRETE WALL WITH PREFORMED CHANNELS. DISCONNECT
SWITCH SHALL BE RATED 30A, 600V, 1 POLE WITH NEMA 4X
ENCLOSURE. PROVIDE LOCKABLE ROTARY SWITCH. DISCONNECT
SWITCH MOUNTING HEIGHT SHALL BE MINIMUM 4 FEET FROM THE VAULT FINISHED FLOOR.
#
1 2 3 4 5 6 7 8 9 4 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN
DESIGNED JOB NO.

DRAWING NO.

SHEET NO.

VERIFY SCALES

IF NOT ONE INCH ON

THIS SHEET, ADJUST

SCALES ACCORDINGLY

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
OF
FILE NAME:
59 PLOT DATE:

SEPTEMBER 2025

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
201631
9/9/2025 11:31:57 PM
R:\d0163214\20163100E0801.rvt
E04

VALVE VAULT
PLANS 36

ELECTRICAL
JGB
NCS
HR
SCALE:

PLAN
SCALE: H 3/8" = 1'-0"
PLAN G 3/8" = 1'-0"
Digitally signed by John G. Briones
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.11 15:33:11-07'00'

Page 1487 of 1832 ends

1 2
1 2
3 4
5 6
7 3
1 2 3 2 5
1 2 3
1 2 3
1 2 3 2 5
3 3
3 4
1 3 5 6 7
1 1
1 3
1 3
3 3
3 3
3 3
3 3
3 3
5 6 7
6 7
6 7
6 7
6 7
6 7
6 7
1 2
3 4
5 6
6<0%2/ '5$:,1*9,6,%/(),(/'6 ),(/'1 ),(/'2 ),(/'3 ),(/'4 ),(/'5 ),(/'6 ),(/'7 ),(/' ,167580(17 1  7$* 5()(5 5()(5 '(6&5,37,21 '(6&5,37,21 $5($12 (  (;,67,1* 35,0$5<(/(0(17 2  /223180%(5 %8,/',1*12 )  )8785( 3  )81&7,21 522012
4  )851,6+('%<
5  /2&$7,21
6  (;,67,1*)8785(
,167580(17 1  7$* 5()(5 5()(5 '(6&5,37,21 '(6&5,37,21 '(6&5,37,21 (  (;,67,1* 287  287'225 &21752/(/(0(17 2  /223180%(5 ,17  ,17(*5$/ )  )8785( 35,0$5<)81&7,21 3  )81&7,21 5(0  5(027(
23(5$725 4  )851,6+('%<
$&&(66,%/( 5  '(6&5,37,21
6  (;,67,1*)8785(
,167580(17 1  7$* 5()(5 5()(5 '(6&5,37,21 '(6&5,37,21 '(6&5,37,21 (  (;,67,1* &21752/(/(0(17 2  /223180%(5 )  )8785(
$8;,/,$5<)81&7,21 3  )81&7,21
23(5$725 4  )851,6+('%<
$&&(66,%/( 5  /2&$7,21
6  (;,67,1*)8785(
,167580(17 1  7$* 5()(5 5()(5 '(6&5,37,21 '(6&5,37,21 '(6&5,37,21 (  (;,67,1* &21752/(/(0(17 2  /223180%(5 )  )8785(
35,0$5<)81&7,21 3  )81&7,21
23(5$725 4  )851,6+('%<
,1$&&(66,%/( 5  /2&$7,21 ;5  3527(&7,21
6  (;,67,1*)8785( 5(/$<
&5  &21752/
5(/$<
;5  ,17(5326,1*
5(/$<
,167580(17 1  7$* 5()(5 5()(5 '(6&5,37,21 '(6&5,37,21 '(6&5,37,21 (  (;,67,1* &21752/(/(0(17 2  /223180%(5 )  )8785(
$8;,/,$5<)81&7,21 3  )81&7,21
23(5$725 4  )851,6+('%<
,1$&&(66,%/( 5  /2&$7,21 ;5  3527(&7,21
6  (;,67,1*)8785( 5(/$<
&5  &21752/
5(/$<
;5  ,17(5326,1*
5(/$<
),(/'(48,30(17 1  7$* 5()(5 5()(5 '(6&5,37,21 '(6&5,37,21 $5($12 (  (;,67,1* 12132:(5(' 2  /223180%(5 %8,/',1*12 )  )8785(
3  )81&7,216,=( 522012
4  )851,6+('%<
5  /2&$7,21
6  (;,67,1*)8785(
),(/'(48,30(17 1  7$* 5()(5 5()(5 '(6&5,37,21 '(6&5,37,21 $5($12 (  (;,67,1* 35,0$5<)81&7,21 2  /223180%(5 %8,/',1*12 )  )8785( 32:(5(' 3  )81&7,21 522012
4  )851,6+('%<
5  /2&$7,21
6  (;,67,1*)8785(
),(/'(48,30(17 1  7$* 0:+  02725 5()(5 '(6&5,37,21 '(6&5,37,21 '(6&5,37,21 (  (;,67,1* $8;,/,$5<)81&7,21 2  /223180%(5 :,1',1* )  )8785(
32:(5(' 3  )81&7,21 +($7(5
4  )851,6+('%< 76+  7(03(5$785(
5  /2&$7,21 6:,7&+
6  (;,67,1*)8785( ;6+  72548(
6:,7&+
),(/'(48,30(17 1  7$* 06  02725 5()(5 )915  )8//92/7$*( 129$&  13 /&3  /2&$/&21752/ (  (;,67,1* 67$57(5'5,9( 2  /223180%(5 67$57(5 1215(9(56,1*67$57(5 29$&  23 3$1(/12 )  )8785( &8%,&/(&$%,1(7 3  7<3( 59$7  5('8&(' )95  )8//92/7$*( 29$&  33 0&&  02725&21752/ 4  92/7$*(32/( 92/7$*($872 5(9(56,1*67$57(5 249$&  23 &(17(512 5  32:(56285&( 75$16)250(5 3:6  3$57:,1',1*67$57(5 249$&  33 3&0  352&(66&21752/ 6  (;,67,1*)8785( 67$57(5 59$7  5('8&('92/7$*($872 49$&  33 02'8/(12 5966  5('8&(' 5966  5('8&('92/7$*( 249$&  33 9&3  9(1'25&21752/ 92/7$*( 62/,'67$7(67$57(5 4169$&  33 3$1(/12
62/,'67$7( 761:  7:263(('6,1*/(
67$57(5 :,1',1*
9)'  9$5,$%/( 762:  7:263(('7:2:,1',1*6
)5(48(1&< 9)'  9$5,$%/()5(48(1&<
'5,9( '5,9(
,167580(17%8%%/(/2&$7,216 127(6
3&6
,167580(177$*,'(17,),&$7,21/(77(567$%/(
23(5$7253,/27'(9,&(/(*(1'
,2
(48,30(177$**,1*7$%/(
,27<3('(6,*1$7,216
23(5$725
,17(5)$&(
&21752/
'(9,&(6
,167580(177<3('(6,*1$7,2167$%/(
)851,6+('%<
)%2 )851,6+('%<2:1(5
)%9 )851,6+('%<9(1'25
32:(5
6285&(
3529,'('%<
3%2 3529,'('%<2:1(5
3%9 3529,'('%<9(1'25
),(/'
6<0%2/ '5$:,1*9,6,%/(),(/'6 ),(/'1 ),(/'2 ),(/'3 ),(/'4 ),(/'5 ),(/'6 ),(/'7 ),(/' +0,6&$'$6<67(0 1  7$* 5()(5 5()(5 $&7,21 '(6&5,37,21 '(6&5,37,21 (  (;,67,1* 23(5$725 2  /223180%(5 $/$50 )  )8785(
,17(5)$&( 3  )81&7,21 63  180(5,&
7(50,1$/ 4  '(6&5,37,21 67$786  6(732,17
5  '(6&5,37,21 75(1'
6  (;,67,1*)8785(
+$5':,5(',2 1  7$* 5()(5 5()(5 $,  $1$/2*,1387 '(6&5,37,21 3$&  352*5$00$%/( (  (;,67,1* 32,17 2  /223180%(5 $2  $1$/2*287387 $8720$7,21 )  )8785( 3  )81&7,21 ',  ',6&5(7(,1387 &21752//(512
4  '(6&5,37,21 '2  ',6&5(7(287387 3/&  352*5$00$%/( 5  /2&$7,21 57'  57',1387 /2*,&
6  (;,67,1*)8785( &21752//(512
7  ,27$%/( 5,2  5(027(,2
9&3  9(1'25&21752/
3$1(/12
1(7:25.62)7,2 1  7$* 5()(5 5()(5 &20081,&$7,2135272&2/ '(6&5,37,21 3$&  352*5$00$%/( (  (;,67,1* 2  /223180%(5 &1(7  &21752/1(7 $8720$7,21 )  )8785( 3  35272&2/ '1(7  '(9,&(1(7 &21752//(512
4  3$1(/ (,3  (7+(51(7,3 3/&  352*5$00$%/(
5  3/& ))  )281'$7,21),(/'%86 /2*,&
6  (;,67,1*)8785( +$57,3  +$5729(5(7+(51(7 &21752//(512 7  ,27$%/( 0$1)  0)535235,(7$5< 5,2  5(027(,2
  6:,7&+6(*0(17 0%578  02'%86578 9&3  9(1'25&21752/ 0%  02'%863/86 3$1(/12
0%7&3  02'%867&3
'3  352),%86'3
3$  352),%863$
31(7  352),1(7
6103  6103Y3
+773  :(%6(59(5
7&3,3

/2&$/ 1  7$* 5()(5 5()(5 $&7,21 '(6&5,37,21 /2,  /2&$/23(5$725 (  (;,67,1* 23(5$725 2  /223180%(5 $/$50 ,17(5)$&(12 )  )8785( ,17(5)$&( 3  )81&7,21 63  180(5,& /&3  /2&$/&21752/ 4  '(6&5,37,21 67$786  6(732,17 3$1(/12
5  /2&$7,21 75(1' 3&0  352&(66&21752/
6  (;,67,1*)8785( 02'8/(12
9&3  9(1'25&21752/
3$1(/12
3,/27'(9,&( 1  7$* 5()(5 5()(5 $0  $8720$18$/ '(6&5,37,21 /&3  /2&$/&21752/ (  (;,67,1* 23(5$725 2  /223180%(5 %<3$66  %<3$66 3$1(/12 )  )8785( ,17(5)$&( 3  )81&7,21 (6723  (0(5*(1&<6723 0&&  02725&21752/ 4  '(6&5,37,21 )5/5  ),;('5$7(/(9(/5$7( &(17(512 5  /2&$7,21 +2$  +$1'2))$872 3&0  352&(66&21752/
6  (;,67,1*)8785( /25  /2&$/2))5(027( 02'8/(12
/26  /2&.2876723 5966  5('8&('92/7$*(
/6  /($'67$1'%< 62/,'67$57(512
/65  /2&$/67235(027( 9&3  9(1'25&21752/
1227  122))/,1(2))/,1( 3$1(/12
75$16,7,21 9)'  9$5,$%/(
2&  23(1&/26( )5(48(1&<
2/2/  21/,1(2))/,1( '5,9(12
22  2))21
26&  23(16723&/26(
567  5(6(7
6$$0  6(0,$872$8720$18$/
6(/  6(/(&7
63'  63(('
66  67$576723
67  6723
32:(5'(9,&( 1  7$* &%  &,5&8,7 5()(5 70  7+(50$/0$*1(7,& 249'&  13 '3  ',675,%87,21 (  (;,67,1* 35,0$5<)81&7,21 2  /223180%(5 %5($.(5 &,5&8,7%5($.(5 249'&  23 3$1(/12 )  )8785( 23(5$725 3  )81&7,21 ',6&  ',6&211(&7 249$&  13 /&3  /2&$/&21752/ $&&(66,%/( 4  92/7$*(32/( )8  )86( 49'&  23 3$1(/12 5  /2&$7,21 129$&  13 /3  /,*+7,1*3$1(/12
6  (;,67,1*)8785( 29$&  23 0&&  02725&21752/
29$&  33 &(17(512
249$&  23 3&0  352&(66&21752/
249$&  33 02'8/(12
49$&  33 33  32:(53$1(/12
249$&  33 9&3  9(1'25&21752/
4169$&  33 3$1(/12
32:(5'(9,&( 1  7$* ',6&  ',6&211(&7 5()(5 '(6&5,37,21 '(6&5,37,21 '(6&5,37,21 (  (;,67,1* $8;,/,$5<)81&7,21 2  /223180%(5 )  )8785(
23(5$725 3  '(6&5,37,21
$&&(66,%/( 4  '(6&5,37,21
5  '(6&5,37,21
6  (;,67,1*)8785(
32:(5'(9,&( 1  7$* &%  &,5&8,7 5()(5 0&3  02725&,5&8,7 249'&  13 '3  ',675,%87,21 (  (;,67,1* 35,0$5<)81&7,21 2  /223180%(5 %5($.(5 3527(&725 249'&  23 3$1(/12 )  )8785( 23(5$725 3  )81&7,21 )8  )86( 66  62/,'67$7( 249$&  13 /&3  /2&$/&21752/ ,1$&&(66,%/( 4  92/7$*(32/( &,5&8,7%5($.(5 49'&  23 3$1(/12 5  /2&$7,21 70  7+(50$/0$*1(7,& 129$&  13 /3  /,*+7,1*3$1(/12 6  (;,67,1*)8785( &,5&8,7%5($.(5 29$&  23 0&&  02725&21752/ 29$&  33 &(17(512
249$&  23 3&0  352&(66&21752/
249$&  33 02'8/(12
49$&  33 33  32:(53$1(/12
249$&  33 9&3  9(1'25&21752/
4169$&  33 3$1(/12
5(9 '$7( %< '(6&5,37,21
'$7(
&+(&.('
'5$:1
'(6,*1('
21631
-2%12
'5$:,1*12
6+((712
6&$/(6$&&25',1*/<
9(5,)<6&$/(6
7+,66+((7$'-867
,)12721(,1&+21
%$5,621(,1&+21
25,*,1$/'5$:,1*
 1
6(37(0%(5225 2)5

&,7<2)9$//(-2

6.<9,(:5(6(592,55(3/$&(0(17352-(&7
1 2 3 4 5 6 7 
1 11 12 13
$
%
&
'
(
)
1 2 3 4 5 6 7 
1 11 12 13
$
%
&
'
(
)
* *
1R245
352-(&712
/$676$9('%<

),/(1$0(

&(
&(
-*%
*11
37 ,167580(17$7,21
6<0%2/6$1'$%%5(9,$7,2161
21631*11GZJ
&<RXQJ
216311
Digitally signed by Daniel S. Robinson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:25:53-07'00'

Page 1488 of 1832 ends

INSTRUMENT OR CONNECTION

TO PROCESS

INTERNAL SYSTEM LINK
(SOFTWARE OR DATA LINK)

PNEUMATIC SIGNAL

ELECTRIC SIGNAL

HYDRAULIC SIGNAL

CAPILLARY TUBE

PRIMARY PROCESS FLOW

IN PIPE

SECONDARY PROCESS FLOW

IN PIPE

PRIMARY PROCESS FLOW

IN CHANNEL

SECONDARY PROCESS FLOW

IN CHANNEL

EQUIPMENT ENCLOSURE

EXISTING

DESIGNATIONS

MISCELLANEOUS P&ID SYMBOLS

PIPE CALLOUT

PROCESS CONTINUATION

P&ID LINE SYMBOLSINSTRUMENT TAG IDENTIFICATION LETTERS

PROCESS LINE SYMBOLS
FUTURE

SIGNAL CONTINUATION

PIPE SIZE
TYP
*
TYPNUM
TYPNUM2
TYPNUM3
TYPNUM4
TYPNUM5
TYPNUM6
?
-

SCHEMATIC DETAIL

TYPICAL DETAIL
// // // // // // //

X X X X X
o o o o o o o o o o o
FUTURE
# DWG NO.

DESC1_
DESC2_
# DWG NO.

DESC1_
DESC2_

CONTINUATION
SHEET
UNIQUE

IDENTIFIER

CONTINUATION
SHEET
UNIQUE

IDENTIFIER

L L L L L L L L L L

INSTRUMENT FUNCTION

MEASURED VARIABLE

ELEMENT

TRANSMITTER

INDICATING TRANSMITTER

CONVERTER TRANSDUCER,

RELAY SPECIAL DEVICES

INDICATOR

RECORDER

CONTROL/COMMAND

INDICATING CONTROLLER

RECORDING CONTROLLER
SWITCH
SWITCH

LOW LOW
SWITCH
LOW
SWITCH
HIGH
SWITCH

HIGH HIGH

SWITCH COMBINATION

HIGH LOW
ACTION
ALARM

LOW LOW
ALARM
LOW
ALARM
HIGH
ALARM

HIGH HIGH

TOTALIZE INDICATOR

TRANSMITTER
VALVE
GAUGE
LIGHT

SPEED SETTING

A ANALYSIS AE AT AIT AY AI AR AC AIC ARC AS ASLL ASL ASH ASHH ASHL AALL AAL AAH AAHH AL

B BURNER FLAME BE BT BIT BY BI BR BC BIC BRC BS BSLL BSL BSH BSHH BALL BAL BAH BAHH BL

C CONDUCTIVITY CE CT CIT CY CI CR CC CIC CRC CS CSLL CSL CSH CSHH CSHL CALL CAL CAH CAHH CL

D DENSITY DE DT DIT DY DI DR DC DIC DRC DS DSLL DSL DSH DSHH DSHL DALL DAL DAH DAHH DL

E VOLTAGE ESL

F FLOW FE FT FIT FY FI FR FC FIC FRC FS FSLL FSL FSH FSHH FSHL FALL FAL FAH FAHH FQI FCV FG FL

FF FLOW RATIO FFY FFI FFC FFIC FFS FFL
H HAND (MANUAL)* HC HS* HA* HV HL HSS
I CURRENT IT IIT lY II IR IC llC IRC IS ISLL ISL ISH ISHH IALL IAL IAH IAHH lL

J POWER JS

K TIME KY KI KR KC KIC KRC KS KSLL KSL KSH KSHH KALL KAL KAH KAHH KV KL

L LEVEL LE LT LIT LY LI LR LC LIC LRC LS LSLL LSL LSH LSHH LSHL LALL LAL LAH LAHH LCV LG LL

M MOISTURE OR HUMIDITY ME MT MIT MY MI MR MC MIC MRC MS MSLL MSL MSH MSHH MALL MAL MAH MAHH ML

N USER'S CHOICE

P PRESSURE OR VACUUM PE PT PIT PY PI PR PC PIC PRC PS PSLL PSL PSH PSHH PSHL PALL PAL PAH PAHH PCV PL

PD DIFFERENTIAL PRESSURE PDT PDIT PDY PDI PDR PDC PDIC PDRC PDS PDSLL PDSL PDSH PDSHH PDALL PDAL PDAH PDAHH PDCV PDL

Q QUANTITY QE QT QIT QY QI QR QS QSLL QSL QSH QSHH QALL QAL QAH QAHH

R RADIATION

S SPEED SE ST SIT SY SI SR SC SIC SRC SS SSLL SSL SSH SSHH SALL SAL SAH SAHH

T TEMPERATURE TE TT TIT TY TI TR TC TIC TRC TS TSLL TSL TSH TSHH TSHL TALL TAL TAH TAHH TCV TL

TD DIFFERENTIAL TEMPERATURE TDT TDIT TDY TDI TDR TDC TDIC TDRC TDS TDSLL TDSL TDSH TDSHH TDALL TDAL TDAH TDAHH TDCV TDL

U MULTIVARIABLE UI UR UC UIC URC US UL

V VISCOSITY VE VT VIT VY VI VR VC VIC VRC VS VSLL VSL VSH VSHH VALL VAL VAH VAHH VL

W WEIGHT WE WT WIT WY WI WR WS WSLL WSL WSH WSHH WALL WAL WAH WAHH

X UNCLASSIFIED XE XT XIT XY XI XR XC XIC XRC XS XSLL XSL XSH XSHH XALL XAL XAH XAHH XCV XG XL

XV VIBRATION XVE XVT XVY XVI XVR XVS XVSH XVSHH XVAH XVAHH XVL

Y STATUS YI YL
Z POSITION ZE ZT ZIT ZY ZI ZC** ZS** ZV ZL**
* REFER TO OPERATOR PILOT DEVICE LEGEND
** LETTER INDICATES POSITION (O=OPEN, C=CLOSED, R=RAISE, L=LOWER, ETC)

I/O TYPE DESIGNATIONS INSTRUMENT TYPE DESIGNATIONS SPECIFIC ABBREVIATIONS

RNG RUNNING SPDC SPEED COMMAND CGD COMBUSTIBLE GAS DETECTOR RTD RESISTANCE TEMP DETECTOR HTR HEATER

FAIL FAILED/FAULT SPDF SPEED FEEDBACK COND CONDUCTIVITY SB SLUDGE BLANKET HTU HEAT TRACE UNIT

FWD RUNNING FORWARD REM LOR IN REMOTE DO DISSOLVED OXYGEN SC STREAMING CURRENT MWH MOTOR WINDING HEATER FAST RUNNING HIGH LOC LOR IN LOCAL FMCW FREQ. MODULATED CONT. WAVE SD SLUDGE DEPTH SV SOLENOID VALVE

SLOW RUNNING LOW AUTO HOA IN AUTO IS INTRINSIC SAFETY BARRIER SH SODIUM HYPOCHLORITE SPD SURGE PROTECTIVE DEVICE REV RUNNING REVERSE HAND HOA IN HAND LEL LOWER EXPLOSIVE LIMIT SO2 SULFUR DIOXIDE UPS UNINTERRUPTIBLE POWER SUPPLY

SVC SOLENOID VALVE CLOSE RST RESET MLSS MIXED LIQUOR SUSPENDED SOLIDS TDR TIME DOMAIN REFLECTOMETRY YA STATUS AUTO PILOT LIGHT

SVO SOLENOID VALVE OPEN ORP OXIDATION REDUCTION POTENTIAL TOC TOTAL ORGANIC CARBON YR STATUS REMOTE PILOT LIGHT RUN RUN P-SUB PRESSURE SUBMERSIBLE TSS TOTAL SUSPENDED SOLIDS Y1 STATE RUNNING PILOT LIGHT SLWC MOTOR START LOW PC PARTICLE COUNTER UVI UV INTENSITY Y2 ALARM FAILED/FAULT PILOT LIGHT

REVC MOTOR START REVERSE PTOF PULSE TIME OF FLIGHT UVT UV TRANSMITTANCE

OPERATOR PILOT DEVICE LEGEND

PILOT DEVICE FUNCTION

DEVICE TYPE

LOCAL-OFF-REMOTE (LOR)OR

LOCAL-STOP-REMOTE (LSR)

STOP(SP)

START (ST)

HAND-OFF-AUTO (HOA)

OFF-ON (OO)

SELECT (SEL)

OPEN-STOP-CLOSE (OSC)

JOG OPEN-HOLD-CLOSE (JOHC)

SEMIAUTO-AUTO-MANUAL (SAAM)

LEAD-LAG-STANDBY (LLGS)

JOG OPEN-JOG CLOSE (JOJC)

ONLINE-OFFLINE (OLOF)

AUTO-MANUAL (AM)

FIXED RATE-LEVEL RATE (FRLR)

OPEN-CLOSE (OC)

NO OFFLINE-OFFLINE

TRANSITION (NOOT)

LOW-HIGH (LH)

RESET (RST)

SPEED (SPD)

START-STOP (STSP)

EQUIPMENT SHUTDOWN (ESD)

BYPASS (BYP)

SILENCE

POSITION (POS)

PILOT DEVICE TAG (HAND SWITCHES) HSA HSB HSC HSD HSE HSF HSG HSH HIS HSJ HSK HSL HSM HSN HSO HSP HSQ HSR HSS HST HSU HSV HSW HSX HSY HSZ

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 20405
PROJECT NO.

LAST SAVED BY:

FILE NAME:

CE
CE
JGB
GN02
38 INSTRUMENTATION
SYMBOLS AND ABBREVIATIONS 2
201631GN02.dwg
CYoung
201631-100000
Digitally signed by Daniel S. Robinson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:25:38-07'00'

Page 1489 of 1832 ends

ACTUATORS
O
C
L
L L

L L L L

L L L L L L L L
BALL

CHECK VALVES PRESSURE VALVES

REGULATING

PRESSURE RELIEF

VACUUM RELIEF
// // //
S
// // //
//
VALVES

AIR-RELIEF
ANGLE
BALL

BUTTERFLY
CONE

DIAPHRAGM
3-WAY PLUG
4-WAY
3-WAY

BALL V-NOTCH
GATE
GLOBE
HOSE
MUD
NEEDLE
PINCH

PLUG ECCENTRIC

PLUG CONCENTRIC

TELESCOPING

PUMP DISCHARGE
S
P
S
// //
// //
// // // // // //
//
P
S

DIAPHRAGM

PNEUMATIC
HAND

HYDRAULIC
//
// // //
S
// // //
S
// // // // // //
//
S
S
S
P
S
P
~
IY
I/P
PIPING

AIR GAP

BLIND FLANGE
DRAIN
PUMPS

AIR DRIVEN

CENTRIFUGAL

DIAPHRAGM
GEAR
PISTON

SUBMERSIBLE

WATER CHAMP
FAN

BASKET STRAINER

COALESCER

EDUCTOR/EJECTOR

VAPORIZER

BLOW-OFF SILENCER

INLINE DUCT

BALANCING DAMPER

GAS CANNON

GRINDER

HEAT EXCHANGER

HORIZONTAL MIXER
FILTER

FILTER SEPARATOR

FLAME ARRESTER

EYEWASH

FINE FILTER

FLOW CONDITIONER

HOSE CONNECTION

INLET STRAINER
MIXER
NOZZLE

RUPTURE DISK

SAMPLE PORT

SIGHT TUBE

VAPOR HEATER
OR
MISC

VALVE DESIGNATIONS

NO NORMALLY OPEN

NC NORMALLY CLOSED

FO FAIL OPEN

FC FAIL CLOSE

FLP FAIL LAST POSITION

SMOKE DETECTOR

FIRE ALARM/SENSOR
HOIST

SOLENOID
// //
// //
// // // // // // //
//
//
// // // //
// //
// // // // // // // //
//
//
//

ELECTRIC

HYDRAULIC

HYDRAULIC

MODULATING

PNEUMATIC

SINGLE SOLENOID

OPEN/CLOSE

PNEUMATIC

SINGLE SOLENOID
w/ SPEED CONTROL

PNEUMATIC

DUAL SOLENOID

OPEN/CLOSE

PNEUMATIC

DUAL SOLENOID

OPEN/HOLD/CLOSE

PNEUMATIC

DUAL SOLENOID

OPEN/CLOSE
w/ SPEED CONTROL

PNEUMATIC

MODULATING

PNEUMATIC

MODULATING

OPEN/CLOSE
w/ SPEED CONTROL

CAPPED OR

PLUGGED

CONCENTRIC

INCREASER

CONCENTRIC

REDUCER

ECCENTRIC

INCREASER

ECCENTRIC

REDUCER

EXPANSION

COUPLING

EXPANSION JOINT

VIBRATION
CENTER

FLEXIBLE

CONNECTION
QUICK

DISCONNECT

PERISTALTIC

OR HOSE

PROGRESSIVE
CAVITY

VERTICAL

TURBINE

VERTICAL

CHOPPER

CENTRIFUGAL

SINGLE STAGE

BLOWER/FAN

CENTRIFUGAL

MULTI STAGE
BLOWER

RECIPROCATING

COMPRESSOR
SCREW

COMPRESSOR

LIQUID RING

COMPRESSOR

ROTARY LOBE
BLOWER

DESICCANT
DRYER

CALIBRATION
COLUMN

PLUG CONCENTRIC
-BURIED VALVE BOX

PLUG CONCENTRIC

LUBRICATED

PLUG CONCENTRIC

LUBRICATED

BURIED VALVE
BOX

PLUG ECCENTRIC
w-VALVE BOX

PLUG ECCENTRIC

LUBRICATED

PLUG ECCENTRIC

LUBRICATED BURIED

VALVE BOX
BUTTERFLYBURIED VALVE BOX

PRESSURE

REDUCING

EXTERNAL

PRESSURE TAP

PRESSURE

REDUCING

SELF CONTAINED

BACKPRESSURE

REGULATING

EXTERNAL TAP

BACKPRESSURE

REGULATING

SELF CONTAINED

DIAPHRAGM
CHECK
L L L

L L L L

INLINE STATIC MIXER

MATERIAL CHANGE

BLOWERS/

COMPRESSORS/FANS

FLAME ARRESTER
w/THERMALLY

OPERATED
VALVE

PERISTALTIC

COMPOSITE

SAMPLER

ORIFICE

RESTRICTION

PULSATION

DAMPENER

REFRIGERATED
DRYER

STRAINER -

MECHANICALLY

CLEANED

STRAINER

WITH BLOW OFF

STRAINER

WYE TYPE

VENT TO

ATMOSPHERE
UNION
TEE
P
P
P

CHEMICAL FEED

DIAPHRAGM
OR
VENT

BACK FLOW

PREVENTER

GATE-BURIED

VALVE BOX

AIR / CHEMICAL

DIFFUSER

EQUIPMENT/INSTRUMENT

LOCATOR
E
H
H
S

LOUVER OR

BACKDRAFT DAMPER
FLOAT

FLANGED

CONNECTION

MISCELLANEOUS
MOTOR
P
LOBE

E ELECTRIC

DOUBLE FLAP

FLAPPER
SWING

SPRING LOADED
SWING

SPRING LOADED

GENERAL

SLANTING DISC

DUCKBILL

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 20405
PROJECT NO.

LAST SAVED BY:

FILE NAME:

CE
CE
JGB
GN03
39 INSTRUMENTATION
SYMBOLS AND ABBREVIATIONS 3
201631GN03.dwg
CYoung
201631-100000
Digitally signed by Daniel S. Robinson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:26:05-07'00'

Page 1490 of 1832 ends

ORIFICE
POSITIVEDISPLACEMENT
VORTEX
V-CONE

THERMAL

CORIOLIS

MAGNETIC

PADDLE WHEEL

ROTAMETER

BUBBLER

CAPACITANCE

ELECTRODE

BALL FLOAT

INVERTED COLUMN

RADAR PTOF

RADAR TDR

ULTRASONIC
GAUGE

PRESSURE SWITCH
KNIFE
SLIDE
SLUICE
STOP
SLIDE
SLUICE
STOP
FLAP
WEIR

PARSHALL

LEOPOLD-LAGCO

PALMER-BOWLUS

TRAPEZOIDAL

REGULAR

CUTTHROAT

RECTANGULAR
w/ END CONTRACTIONS
PROPELLERTURBINE

VENTURI TUBE

OR FLOW NOZZLE

DIFFERENTIAL

PRESSURE

SUSPENDED/

SUBMERSIBLE
SEAL

ANNULAR
SEAL

DIAPHRAGM
SEAL

SANITARY

PRESSURE SWITCH

MANOMETER

PRESSURE DIFFERENTIAL PRESSURE PRESSURE SEALS
GAUGE

DIFFERENTIAL

INDICATOR

PRESSURE

TRANSMITTER

DIFFERENTIAL

PRESSURE
SWITCH

DIFFERENTIAL

PRESSURE

TRANSMITTER

TUNING FORK
PISTON
WEIRS

SIDE VIEW PLAN VIEW

FLUMESFLOW LEVEL

SIDE VIEW PLAN VIEW

RECTANGULAR
w/o END CONTRACTIONS

RECTANGULAR
w/o END CONTRACTIONS

RECTANGULAR
w/ END CONTRACTIONS

V-NOTCH
(TRIANGULAR)

V-NOTCH
(TRIANGULAR)

TRAPEZOIDAL
(CIPOLLETTI)

TRAPEZOIDAL
(CIPOLLETTI)

PRESSURE/VACUUM

EXAMPLE
GATES

PITOT TUBE

ANNUBAR

ULTRASONIC

ULTRASONIC
BIOGAS

THERMOMETER

PLATFORM SCALE

TEMPERATURE
w/THERMOWELL

TEMPERATURE
GAUGE
WEIGHT

TEMPERATURE
PROBE
RADAR
(FREQUENCY

MODULATED

CONTINUOUS WAVE)

BUTTERFLY
K
N
A
T
T

NETWORKS
F
F
F
F

FIBER LINE

REPRESENTS ONE
24-STRAND FIBER

OPTIC CABLE
24/FO-SM
F
F
F
F

FIBER LINE

REPRESENTS TWO
24-STRAND FIBER

OPTIC CABLES
(2) 24/FO-SM (1) 24/FO-SM EA.

EACH FIBER LINE

REPRESENTS ONE
24-STRAND FIBER

OPTIC CABLE

FIBER ABBREVIATIONS
##/FO-XX
## = STRAND COUNT
FO = FIBER OPTIC
XX = MODE
SM = SINGLE MODE
MM = MULTIMODE
C
C
(4)

COPPER LINE

REPRESENTS FOUR

COPPER ETHERNET
CABLES
C
C
C
C
(2) EA.

EACH COPPER LINE

REPRESENTS TWO

COPPER ETHERNET
CABLES

NETWORK ABBREVIATIONS

VLAN SYMBOLS
= BUSINESS NETWORK
= SECURITY CONTROL NETWORK
= BUILDING MANAGEMENT SYSTEM
= PROCESS CONTROL NETWORK

MISCELLANEOUS NETWORK SYMBOLS

NETWORK CABLE CONTINUATIONS
UNIQUE

IDENTIFIER

TOP OF PAGE STYLE

CONTINUATION
UNIQUE

IDENTIFIER

FIELD NETWORK DEVICE

NETWORK EQUIPMENT CALLOUT
TAG
DESC 1

CABLE CALLOUTS AND ABBREVIATIONS
BMS
BSN
FCN
MIN
PCN
PLCN
SCN
PCN-W
NR
NP
ES
FPP
= BUILDING MANAGEMENT SYSTEM
= BUSINESS NETWORK
= FIELD CONTROL NETWORK
= MAINTENANCE INFORMATION NETWORK
= PROCESS CONTROL NETWORK
= PLC NETWORK
= SECURITY CONTROL NETWORK
= WIRELESS PROCESS CONTROL NETWORK
= NETWORK RACK
= NETWORK PANEL
= ETHERNET SWITCH
= FIBER PATCH PANEL

COPPER ETHERNET

FIBER OPTIC ETHERNET

WIRELESS

PROFIBUS DP

PROFIBUS PA

NETWORK LINE SYMBOLS

BOTTOM/LEFT OF PAGE

STYLE CONTINUATION

CONTINUATION
SHEET

CONTINUATION
SHEET

C C C C C

F F F F F

PBD PBD PBD PBD PBD

W W W W W

PBA PBA PBA PBA PBA
SEGMENT #

P&ID DRAWING REFERENCE
DESC 3
DESC 2
DESC 1
TAG

PROTOCOL

PANEL TAG

PLC TAG

DEVICE SPECIFIC
SYMBOL
#
DWG NO.

DESC 1
DESC 2
DESC 3
#
DWG NO.

DESC 1
DESC 2
DESC 3
= WIRELESS PROCESS CONTROL NETWORK
= MAINTENANCE INFORMATION NETWORK
= PLC NETWORK
= FIELD CONTROL NETWORK
SERIAL DATA o o o o o o o o o o o o

DISPLACEMENT

SHUTTLE

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 20405
PROJECT NO.

LAST SAVED BY:

FILE NAME:

CE
CE
JGB
GN04
40 INSTRUMENTATION
SYMBOLS AND ABBREVIATIONS 4
201631GN04.dwg
CYoung
201631-100000
Digitally signed by Daniel S. Robinson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:24:12-07'00'

Page 1491 of 1832 ends

POWER SOURCE FIELD I/O
24" R
24" SD

SANITARY DRAIN
12" R

DRAIN/OVERFLOW

CATCH BASIN
EX 24" W
SYSTEM
TYP
*
NP122
MAX LEVEL ELEV. 292.0

MIN LEVEL
24" W
24" W
INLET
OUTLET

RESERVOIR CONTROL

VALVE VAULT

OVERFLOW
DRAIN

L L L L L L L L L L
3" PD
# KEY NOTES:

1. RESERVOIR CONTROL VALVE.
1 PROJECT NO.

LAST SAVED BY:

FILE NAME:

DSR
MCG
JGB
N01
41 INSTRUMENTATION

WATER STORAGE TANK P&ID
201631N01.dwg
LRivas
201631-100000

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 20405
Digitally signed by Daniel S. Robinson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:25:26-07'00'

Page 1492 of 1832 ends

RADIO

TRANSCEIVER
& CONTROLLER
OPEN EYE OE-MDX0804
NVR

PLC CONTROLLER
POWER

ADDRESS/ERROR

MODULE NET
# KEY NOTES:

1. EXISTING PLC RADIO AND ANTENNA TO BE REUSED.

2. ACCESS CONTROL SYSTEM TO BE PROVIDED BY THE CITY
PREFERRED VENDOR:

BRANDON HERD

ACCESS SYSTEMS, INC
4947 HILLSDALE CIRCLE
EL DORADO HILLS, CA 95762
(916) 673-8366 CELL
(916) 941-8099 OFFICE
(916) 941-8017 FAX
CA LIC# 814697
NV LIC# 0085320
PNL-1
o
o
o
o
o
o
o
1 1
MERAKI MG41E

CELLULAR MODEM

ACCESS CONTROL
SYSTEM
2 C
C C
C
C
C
C
C
OPEN EYE OE-C7088AWR

CAMERAS
C
C
C
C
C
C
C
C
MERAKI MX68

FIREWALL
CAT 6
CAT 6 CAT 6
CAT 6 CAT 6
2 2
2 2
PROJECT NO.

LAST SAVED BY:

FILE NAME:

DSR
KMM
JGB
N02
42 INSTRUMENTATION

FIELD NETWORK DIAGRAM
201631N02.dwg
BRoepken
201631-100000

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 20405
Digitally signed by Daniel S. Robinson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:25:14-07'00'

Page 1493 of 1832 ends

1/4
"
M
AX 1/4
"
M
AX
MIN
2"
3 1/2"
AC510
AC510
AC510
AC510
4 "
1"

SIDE OF GAP

PLATES ON THIS

DO NOT FASTEN
AC500
TYP

GUARDRAIL - HANDRAIL - NOTES
NS 06/21/19
TYP
AC300
R
U
N
G
S
E
Q
U
ALLY
S
PA
C
ED
@ 12
"
O
C
M
AX

LADDER - ALUMINUM - WALL
30" MAX
24" MIN
S 12/28/20
AC504
TYP
3'-6
"
2'-10
"
3'-6
"
6'-0" MAX
MAX
6"
3'-6
"
2'-10
"

GUARDRAIL - THREE RAIL
NS SHEET 1 OF 3 06/21/19
AC504
TYP
2'-10
"

GUARDRAIL - THREE RAIL
NS SHEET 3 OF 3 06/21/19
TYP
AC510 GUARDRAIL - MOUNTING
NS SHEET 1 OF 2 06/21/19
TYP
AC510 GUARDRAIL - MOUNTING
NS SHEET 1 OF 2 06/21/19
TYP
AC510 GUARDRAIL - MOUNTING
NS SHEET 2 OF 2 06/21/19
AC504
TYP
3'-6
"
2'-10
"
5'-0" MAX
3'-6
"
2'-10
"

GUARDRAIL - THREE RAIL
NS SHEET 2 OF 3 06/21/19
-
A
1/4
"
M
AX 1/4
"
M
AX
6" MIN
6 " 1/2
"
6" MIN
6 " 1/2
"
6"
1/4
"
M
AX
1/4
"
M
AX
6 "
6"
1/4
"
M
AX
1/4
"
M
AX
6 "
6" MIN
4 1/4"

KICKPLATE
5 NOTE
AC500
AC500
MIN 1/4"Ø DRAIN
MIN 1/4"Ø DRAIN

GRATING STOP

GRATING
TOP & SIDES.

MIN 2" CLR
MIN (1) #4.

DRAIN HOLE INVERT

FOAM INSERT TO
KICKPLATE. SEE NOTE 4.

MIN 1/4"Ø DRAIN
MIN 1/4"Ø DRAIN

GRATING STOP

GRATING
TOP & SIDES.

MIN 2" CLR
MIN (1) #4.

DRAIN HOLE INVERT

FOAM INSERT TO
KICKPLATE. SEE NOTE 4.

CE
CE
JAD
TA01
43 TYPICAL DETAILS
ARCHITECTURAL 1
201631-100000 201631TA01.dgn
JB
aum
barger

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
E
Q
E
Q
E
Q
E
Q
~
~
1"

EDGE OF

CONCRETE
E
Q
E
Q
E
Q
E
Q
E
Q
E
Q
E
Q
E
Q

MOUNTED
TOP
~

FOR CLARITY

NOT SHOWN

KICKPLATE

KICKPLATE JOINT - ELEVATION
FLANGE WIDTH = 1".

MIN 1/8" THICK. MIN

KICKPLATE CHANNEL

EA SIDE
PL1/8"x3 1/2"x4"

WASHERS & NUTS
(2) 1/4"Ø SST BOLTS,
GAP
POST

FIXED END SLIP END
1" MIN
J K
G
H

RAIL SLIP JOINT - PLAN
FIT

FOR FREE

REAM PIPE

SLEEVE ASSEMBLY

MFRS SPLICE
GAP

FOR CLARITY)
(KICKPLATE NOT SHOWN
M
IN
6 "
TYP
TYP
TYP
TYP

L GUARDRAIL POST
C C

L GUARDRAIL POST
2 " 1"
NEOPRENE GASKET BETWEEN ALUMINUM AND STEEL.

17. COAT SURFACES OF ALUMINUM IN CONTACT WITH CONCRETE AS SPECIFIED. PROVIDE LOCK.

MAINTAIN 1/4" MAX CLEAR SPACING. HAND TIGHTEN AND CENTER PUNCH BOLT THREADS TO

GUARDRAIL, PROVIDE STANDARD SPACER BLOCK BETWEEN POST AND KICKPLATE TO KICKPLATE TO POST WITH BOTTOM 1/4" CLEAR ABOVE FLOOR. FOR SIDE MOUNTED PLATE AND SHALL BE ATTACHED WITH SST BOLTS IN 5/16" x 3/4" SLOTTED HOLES. BOLT WHERE GUARDRAIL IS MOUNTED ON A 4" MIN CURB. KICKPLATE MAY BE EXTRUDED OR BENT

16. PROVIDE KICKPLATE AT ALL LOCATIONS EXCEPT AT SLOPING GUARDRAIL ON STAIRS AND GROUND SMOOTH.

15. JOINTS FOR STAINLESS STEEL GUARDRAIL AND HANDRAIL SHALL BE COPED, WELDED, AND MATERIAL AS THE GUARDRAIL.

14. MATERIAL FOR KICKPLATE CHANNEL SLIDING JOINT PLATES, SHALL BE OF THE SAME FOR THE FULL RANGE OF MOVEMENT.

CONCRETE EXPANSION JOINT. MAKE INSERT SLEEVES IN RAILS LONG ENOUGH TO ALLOW JOINTS, PROVIDE MINIMUM 1" GAP IN SLIDING JOINTS BUT NOT LESS THAN WIDTH OF INTERPOLATE GAP FOR OTHER INSTALLATION TEMPERATURES. AT CONCRETE EXPANSION BASED ON TEMPERATURE OF GUARDRAIL. PROVIDE 1/4" GAP AT 100°F AND 5/8" GAP AT 0°F.

LOCATE SLIDING JOINTS NEAR FACE OF POST. GAP AT TIME OF INSTALLATION SHALL BE

13. PROVIDE SLIDING JOINTS AT 24' MAX SPACING FOR EXPANSION OF RAIL AND KICKPLATE.

BE ALUMINUM OR STAINLESS STEEL.

REINFORCED CONNECTION FROM POST TO PLATE. PLATE AND REINFORCED INSERTS SHALL

12. FOR GUARDRAIL POSTS MOUNTED TO BEAM OR STAIR CHANNEL, PROVIDE MANUFACTURERS

11. PLACE GUARDRAIL POSTS OPPOSITE EACH OTHER WHERE RAILINGS ARE PARALLEL.

EDGE OF CONCRETE STAIR NOSINGS UNLESS OTHERWISE INDICATED ON THE DRAWINGS.

10. PLACE CENTER OF EMBEDDED POSTS 6" FROM EDGE OF CONCRETE AND 6" FROM FRONT

9. GUARDRAIL SHALL BE FIXED UNLESS OTHERWISE INDICATED ON THE DRAWINGS.

ABOVE LANDINGS OR TREAD NOSINGS. PROVIDE MATCHING HANDRAIL ON OPPOSITE SIDE.

8. FOR WALL MOUNTED HANDRAILS, PROVIDE SINGLE RAIL WITH TOP OF RAIL AT 2'-10" HEIGHT

7. MAKE INSIDE HANDRAIL ON SWITCHBACK STAIRS CONTINUOUS.

PERPENDICULAR TO AND IMPEDES EXIT FLOW.

HANDRAIL EXTENSION ON STAIR MOUNTED GUARDRAIL MAY BE OMITTED WHERE IT IS

6. PROVIDE HANDRAIL EXTENSIONS AT BOTH SIDES OF STAIRS AT TOP AND BOTTOM.

STAIR.

5. PROVIDE CONTINUOUS HANDRAIL GRIPPING SURFACES FOR THE FULL LENGTH OF THE

4. PROVIDE HANDRAIL AT BOTH SIDES OF EVERY STAIR HAVING 2 OR MORE RISERS.

3. SEE DRAWINGS AND SPECIFICATIONS FOR GUARDRAIL MATERIAL TYPE(S).

GUARDRAIL AT ROOF LOCATIONS.

FORMING A PROTECTIVE BARRIER. PARAPET WALL 42" OR MORE IN HEIGHT MAY BE THE THAN 30" ABOVE GRADE OR ADJACENT CONSTRUCTION, PROVIDE 42" HIGH GUARDRAIL

2. WHERE EQUIPMENT IS LOCATED LESS THAN 10' FROM EDGE OF ROOF AND ELEVATED MORE ELEVATED MORE THAN 30" ABOVE GRADE OR ADJACENT CONSTRUCTION.

1. PROVIDE GUARDRAILS AT STAIRS AND AT OPEN SIDED WALKING SURFACES THAT ARE NOTES:

A
-

SECTION

WELDING (TYP)

GRIND SMOOTH AFTER

RADIUS OF GUARDRAIL POST,

BEND BAR SIDE RAILS TO

LANDING LEVEL

TOP RUNG AT
1/2" RADIUS

SIDE RAILS
1/2 x 4

AL RECT
1/8" RADIUS

SMOOTH TO

CORNERS

ROUND ALL
1/4
TYP
1/4
1/4
1'-4
"
8"
4"
TYP
AN
C
H
O
R
S
TR
AP
S.

S
PA
C
E
@
6'-0
"
O
C
M
AX.
1'-6"
3'-6
"

OTHERWISE INDICATED)

GATE (TYP UNLESS

ELEVATION
RAILS AND PLUG WELD. (TYP)

EXTEND HALF WAY THROUGH
TREAD ON TOP SURFACE.

AL 1" SQ SOLID RUNGS W/

DRAWINGS

INDICATED IN THE

GUARDRAIL, TYPE AS
GROUT
MINIMUM 1" NON-SHRINK
DWGS

WALL, SEE

MASONRY

CONC OR
MASONRY CONSTRUCTION. (TYP)

ANCHOR INTO GROUTED CELL AT
WALL W/ 5/8"Ø SST CONC ANCHORS.

WELD TO LADDER AND FASTEN TO
AL RECT 3/8 x 3 ANCHOR STRAP.
5/8"Ø SST CONC ANCHORS

FASTEN TO FLOOR W/

4. WHERE GUARDRAIL IS SST, BOLT PIPE TO RAIL W/ 2 - 1/2"Ø SST BOLTS.

SLEEVES AND WASHERS AT DISSIMILAR METALS, AS SPECIFIED.

3. COAT ALL AL SURFACES IN CONTACT W/ CONC AND MASONRY, AND INSTALL ISOLATION (2'-3" AT SMOOTH WALL). 1'-3" EACH SIDE OF CENTER LINE, ON EACH SIDE OF LADDER.

2. MINIMUM CLEARANCE TO ANY OBSTRUCTION ADJACENT TO LADDER: 2'-6" ON CLIMBING SIDE

1. INSTALL FALL PREVENTION SYSTEM PER SPEC WHERE HEIGHT OF LADDER EXCEEDS 24'-0".

NOTES:

GUARDRAIL ELEVATION

TOP OF STAIR CORNER END

HANDRAIL
4"R (TYP)
4"R (TYP)

GUARDRAIL

HANDRAIL

KICKPLATE
@RAILS AND

SLIP JOINT

METAL BEAM

SURFACE

WALKING

KICKPLATE

PER DWGS
HEIGHT
CURB

MOUNTED
BEAM

MOUNTED
SIDE

MOUNTED
CURB

MOUNTED
EMBED
4"
12" (MIN)
6" (TYP)
12" (MIN)
~

FOR CLARITY

NOT SHOWN

KICKPLATE
1'-0 1/2"
1'-0 1/2"
1'-5
"
1'-2"

BOT OF STAIR
EA WAY
1'-2"
1 1/2"Ø PIPE

GUARDRAIL

HANDRAIL DETAILS

POST BRACKET

WALL BRACKET

SUPPORT POST

GUARDRAIL

MOUNTED HANDRAIL

GUARDRAIL

HANDRAIL

GUARDRAIL POST

ELEVATION PLAN

ELEVATION PLAN
~
12" EXTENSION
12" EXTENSION

TERMINATION AT WALL

TERMINATION AT POST

FASTENING

CONCEALED

MFR DETAIL FOR

FASTENING

CONCEALED

MFR DETAIL FOR
OC MAX
BRACKET @ 5'-0"

MFR WALL

BRACKET (TYP)

MFR POST

WALL-MOUNTED HANDRAIL
4" EMBED TYP
ANCHOR. MIN
1/2"Ø SST CONC

SIDE MOUNTED POST

EMBEDDED POST

REMOVABLE

CHANNEL MOUNTED POST

FOAM INSERT

PLASTIC PIPE OR
FORM W/ 2 1/2" ID

LANDING)

AT STAIR
CHANNEL (E.G.:

EMBEDDED POST -
CLEAR TOP & SIDES.

MIN (1) #4. MIN 2"
SEE NOTE 4.

KICKPLATE.

SEE NOTE 4.

KICKPLATE.

CLEAR TOP & SIDES.

MIN (1) #4. MIN 2"
1/2
"
TOP & SIDES.

MIN 2" CLEAR
MIN (1) #4.

HOLE INVERT.

FILL POST TO DRAIN
NON-SHRINK GROUT.
(4) 1/2"Ø SST BOLTS

BRACKET W/ MIN
W/ 9/16"Ø HOLE
SPACER PL 1" x 2" x 2"
HOLE
1/8"Ø DRAIN
MIN 4" EMBED.

THREADED ROD SET W/ EPOXY.

BRACKET W/ MIN (4) 1/2"Ø SST

SIDE MOUNTED POST

EMBEDDED POST

REMOVABLE

CHANNEL MOUNTED POST

FOAM INSERT

PLASTIC PIPE OR
FORM W/ 2 1/2" ID

LANDING)

AT STAIR
CHANNEL (E.G.:

EMBEDDED POST -
CLEAR TOP & SIDES.

MIN (1) #4. MIN 2"
SEE NOTE 4.

KICKPLATE.

SEE NOTE 4.

KICKPLATE.

CLEAR TOP & SIDES.

MIN (1) #4. MIN 2"
1/2
"
TOP & SIDES.

MIN 2" CLEAR
MIN (1) #4.

HOLE INVERT.

FILL POST TO DRAIN
NON-SHRINK GROUT.
(4) 1/2"Ø SST BOLTS

BRACKET W/ MIN
W/ 9/16"Ø HOLE
SPACER PL 1" x 2" x 2"
HOLE
1/8"Ø DRAIN
MIN 4" EMBED.

THREADED ROD SET W/ EPOXY.

BRACKET W/ MIN (4) 1/2"Ø SST
AND CONTRACTION.

BOLT. PROVIDE WASHER AND DOUBLE NUTS. INSIDE NUT FINGER-TIGHT TO PERMIT EXPANSION

4. KICKPLATE CONNECTION AT POST: MIN 3/4" HORIZONTAL SLOTTED HOLE IN CHANNEL W/ MIN 1/4"Ø

3. COAT ALUMINUM SURFACES IN CONTACT WITH CONCRETE OR DISSIMILAR METALS AS SPECIFIED.

2. SEE DRAWINGS FOR MATERIAL TYPES.

1. FOR ADDITIONAL REQUIREMENTS, SEE DETAIL AC500/TYP.

NOTES:

STAIR GUARDRAIL/HANDRAIL ELEVATION

KICKPLATE

GUARDRAIL

HANDRAIL
6" (TYP)
6"
1'-0 1/2"
1'-0 1/2"
4"
3'-6
"

EXTENSION (MIN)
12" HANDRAIL

EXTENSION (MIN)
12" HANDRAIL

5. AT CURB, USE EMBEDDED OR TOP MOUNTED POST AS INDICATED ON THE DRAWINGS.

HANDRAIL IS CONTINUOUS AT SWITCHBACK STAIR.

4. HANDRAIL EXTENSIONS ARE REQUIRED ON BOTH SIDES OF STAIR, EXCEPT WHERE INSIDE AC510/TYP FOR SPECIFIC MOUNTING REQUIREMENTS.

3. VARIOUS POST MOUNTING DETAILS ARE ILLUSTRATED. SEE DRAWINGS AND DETAIL

2. SEE SPECIFICATIONS AND DETAIL AC500/TYP FOR ADDITIONAL REQUIREMENTS.

THE BUILDING CODE.

OPERATOR ONLY ACCESS IS REQUIRED. DETAILS AND INSTALLATION SHALL COMPLY WITH

1. THIS DETAIL IS APPLICABLE AT PRIVATE STAIRS IN F, H, AND S OCCUPANCIES WHERE NOTES:

F
-
INSERT
F
-
PLAN

TOP MOUNTED POST
A
B
E
C
D

F BASE PL
-
INSERT
F
-
PLAN

TOP MOUNTED POST
A
B
E
C
D

BASE PL

STRINGER MOUNTED POST

BEAM MOUNTED POST
INSERT
INSERT
3'-6
"
2'-10
"
3'-6
"
1'-5
"
1/8
1/8
HOLE
1/8"Ø DRAIN

FOR EA POST SLEEVE

TREAD PLATE COVER
PLATE (PROVIDE 1/4"

LEDGE FOR COVER
40 PIPE
2 1/2"Ø SCH
40 PIPE
2"Ø SCH
PL 3/16" x 3"Ø
1/8
1/8
HOLE
1/8"Ø DRAIN

FOR EA POST SLEEVE

TREAD PLATE COVER
PLATE (PROVIDE 1/4"

LEDGE FOR COVER
40 PIPE
2 1/2"Ø SCH
40 PIPE
2"Ø SCH
PL 3/16" x 3"Ø
TOP OF

STRINGER

TOP OF STAIR
BEAM
BOLTS.

W/ MIN (2) 5/8"Ø SST

MFR'S BRACKET
BOLTS.

W/ MIN (2) 5/8"Ø SST

MFR'S BRACKET
4 1/2" MAX
PLATE
KICKTYP
TYP
C C

L GUARDRAIL POST L GUARDRAIL POST
MIN

L GUARDRAIL POST C
C
POST

L REMOVABLE GUARDRAIL
C

L GUARDRAIL POST

MIN MIN
ANCHORS. MIN 4" EMBED.

MIN (4) SST CONC

MFR'S BRACKET W/
(KICKPLATE NOT SHOWN FOR CLARITY)
C C

L GUARDRAIL POST L GUARDRAIL POST
MIN

L GUARDRAIL POST C
C
POST

L REMOVABLE GUARDRAIL
C

L GUARDRAIL POST

MIN MIN
ANCHORS. MIN 4" EMBED.

MIN (4) SST CONC

MFR'S BRACKET W/
(KICKPLATE NOT SHOWN FOR CLARITY)
1 1/2" CLEAR
1 1/2" CLEAR
4 1/2" MAX
P
lotD
ate: 9-S
E
P
-2025 10:59:29
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:29:06-07'00'

Page 1494 of 1832 ends

AC514
TYP
2 1/2"
3'-6
"
3 1/2" (TYP)

GUARDRAIL - GATE - THREE RAIL
S 06/21/19
AG229
TYP

SPLASH BLOCK - CONCRETE - SURFACE MOUNTED
06/21/19
CE
CE
JAD
TA02
44 TYPICAL DETAILS
ARCHITECTURAL 2
201631-100000 201631TA02.dgn
JB
aum
barger

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

GUARDRAIL GATE
1/4" PL GATE STOP.

ELEVATION

SLEEVE FULL HEIGHT

SELF CLOSING HINGE

HINGE RINGS
PLAN
4" R (TYP)
4'-0" MAX.

OR TO SUIT EQUIP FURNISHED.

AS INDICATED ON THE DRAWING

SST GATE LATCH

TO SUIT HINGE PROVIDED

WITH SST RIVETS

NYLON GASKET

REINFORCE WITH INTERNAL

2. GATE SHALL OPEN TOWARD THE WALKWAY.

1. GATE MATERIAL AND FINISH SHALL MATCH GUARDRAIL.

NOTES:

WELD TO GUARDRAIL POST.

0.74"Ø SST PIN (TYP)
2"
2"
2"
1"
1'-2"
4"
2'-0"
51/2
"
2 "
4"
2"
2"
2"
1"
1'-2"
4"
2'-0"
51/2
"
2 "
4"
P
lotD
ate: 9-S
E
P
-2025 11:00:01P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:29:29-07'00'

Page 1495 of 1832 ends

12"
TYP
SN
CY111 PIPE TRENCH
SHEET 1 OF 2 08/19/22
TYP
SN
CY111
SHEET 2 OF 2

PIPE TRENCH
08/19/22
TYP
N
CF161
-
B
-
B
-
A
3'-6
"
1"
1"
12/29/2020

GUARD POST - REMOVABLE
TYP
CR102 YARD CURB AND GUTTER
A
-
1" 6"
MIN
6"
M
IN
6 "
2'-0"
MIN
8"
12/24/2020
TYP
SN
CY131 THRUST RESTRAINT - BURIED THRUST BLOCK
"L"/2
"L"/2
9" MIN

0.25 Ø
8" MIN
08/19/22
TYP
09/13/23
CF202
10'-0" MAX 10'-0" MAX
SHEET 2 OF 2

FENCE AND GATE - CHAIN LINK
R
TYP
CR106
12/29/2020

YARD CURB - WOOD HEADER
TYP
09/13/23
CF202
R
10'-0" 10'-0"

PER PLANS
SHEET 1 OF 2

FENCE AND GATE - CHAIN LINK
8'-0
"
CE
CE
DGB
TC01
45 TYPICAL DETAILS
CIVIL 1
201631-100000 201631TC01.dgn
D
F
assbinder

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
NOTES:

OPERATE SIMULTANEOUSLY WHEN CONTROLLED BY MOTOR OPERATOR.

4.OMIT SLIDING POST FROM DOUBLE LEAF ENTRANCE GATE. BOTH GATE LEAVES SHALL

3. SEE SECTION 02820 FOR ADDITIONAL REQUIREMENTS.

2. PROVIDE 6-STRAND BARBED WIRE IN "V" CONFIGURATION PER SECTION 02820.

INDICATED ON SECTION 02820.

1. CONTRACTOR SHALL OMIT TOP RAIL SHOWN ON DETAIL AND PROVIDE TENSION WIRE AS 1 2

TRENCH WIDTH

AS SPECIFIED

SAW CUT

EXISTING GRADE

EXISTING SUBGRADE

UNDISTURBED SOIL

SHOULDER

BEGINNING OF

PAVEMENT, OR

FACE, EDGE OF

EXIST GUTTER
TAPE

CAUTIONARY MARKER

PAVEMENT SECTION
(SEE DRAWINGS)

NEW PAVEMENT
(SEE DRAWINGS)

SUBGRADE

NEW PAVEMENT

AND IN OPEN AREAS

OUTSIDE ROADWAY

AND PAVED AREAS

IN ROADWAYS

BACKFILL

PIPE FOUNDATION
ZONE

EMBEDMENT
PIPE
SHEET 2

SEE DETAILS,

ON THE DRAWINGS

ELEVATION INDICATED

GRADE / GRADE TO

MATCH EXISTING

BEDDING
P

STABILIZATION FABRIC
IPEOD
AREA

PAVEMENT IN THIS

AND REPLACE
THAN 3'-0", REMOVE
VARIES. IF LESS
SEE NOTE 2
SLOPE
SEE NOTE 1

SHORING

3. SEE SPECIFICATIONS FOR DEPTH AND WIDTH REQUIREMENTS.

2. SEE SPECIFICATIONS FOR SLOPE REQUIREMENTS.

1. SEE SPECIFICATIONS FOR SHORING REQUIREMENTS.

NOTES:

BACKFILL
-
B

PIPE FOUNDATION

TRENCH WIDTH
-
A

PIPE FOUNDATION

PIPE SPRINGLINE

TRENCH WIDTH

PIPE SPRINGLINE
PIPEOD
PIPEOD
CL
CL
(ABOVE SPRINGLINE)

BACKFILL
(BELOW SPRINGLINE)

HAUNCH ZONE

EMBEDMENT ZONE
PIPE

EMBEDMENT ZONE
PIPE

PIPE ZONE EMBEDMENT - RIGID PIPE

PIPE ZONE EMBEDMENT - FLEXIBLE PIPE

PVC PIPE SLEEVE
CLASS "C" CONCRETE
4"Ø GALV SCH 40 STEEL POST.
4'-0
"
6 "

MATERIAL ALL

CONCRETE PAVEMENT
SEE DRAWINGS.

CONCRETE PAVEMENT

WELD ON CAP

PAINT SAFETY YELLOW PER
ANSI Z535.1. 1/2" BITUMINOUS

FIBER EXP JOINT

AROUND (UNLESS

OTHERWISE INDICATED

ON THE DRAWINGS)

FINISHED GRADE

AC PAVEMENT OR

FINISHED GRADE
OR AC PAVEMENT.
3/4" R (TYP

AC PAVING
1/2" R

BOTH SIDES)
6 "

SECTION
1'-5"
1"
1"
#4 @ 12"

DRAWINGS
ON THE

INDICATED

OTHERWISE
6" UNLESS
4 - #4

CURB AND GUTTER
6" MIN. ABC UNDER
WHERE INDICATED ON THE DRAWINGS.

5. DEPRESS CURB AT DRIVEWAYS, ROADWAYS, SIDEWALKS FOR HANDICAPPED ACCESS, AND FACES, PROVIDE 1/2" RADIUSED EDGE EACH SIDE AT JOINTS.

4. PROVIDE WEAKENED PLANE JOINTS AT 10 FEET OC MAXIMUM. AT FRONT, TOP AND BACK

3. DO NOT PASS REINFORCING BARS THROUGH EXPANSION JOINTS.

EXPANSI0N JOINT MATERIAL.

WIDE WITH 1/4" RADIUS CONCRETE EDGES AT BOTH SIDES OF JOINT. USE BITUMINOUS FIBER STRUCTURES, AND AT MAXIMUM SPACING OF 30 FEET. EXPANSION JOINTS SHALL BE 3/4"

CURVATURE, AT BOTH SIDES OF DRIVEWAYS AND WALKWAYS, AT CURB RETURNS, AT

2. PROVIDE 3/4" EXPANSION JOINTS AT ENDS OF CONCRETE PLACEMENT, AT POINTS OF BACK.

1. FINISH CURB ON TOP, DOWN FRONT FACE AND ACROSS GUTTER TO PAVING, AND 2" DOWN NOTES:

TOOLED EDGE
1/4" RADIUS
(SEE NOTE 4)
JOINTS.

PLANE CONTROL
(SEE NOTE 5)
CURB

DEPRESSED
1/2" DEEP, WEAKENED

UNDISTURBED SOIL

OBTAIN BEARING AREA AGAINST
LENGTH "L" AS REQUIRED TO
SLOPE

MAXIMUM
2 1
TO
O
B
TA
IN
B
EAR
IN
G
AR
EA

ADDITIONAL EXCAVATION IF NECESSARY
FORCE
THRUST

OBTAIN BEARING AREA AGAINST
LENGTH "L" AS REQUIRED TO

UNDISTURBED SOIL
AG
A
IN
S
T
U
N
D
IS
TU
R
B
ED
S
O
IL

TO OBTAIN REQUIRED BEARING AREA
"H
"
A
S
R
E
Q
U
IR
ED

THRUST FORCE
"L"/2 "L"/2
"L"/2 "L"/2

OBTAIN REQUIRED BEARING AREA

OR SLOPE UP IF NECESSARY TO

PLACE CONC LEVEL WITH TOP OF PIPE

3. THRUST BLOCK SHALL BEAR ON UNDISTURBED SOIL.

2. CONCRETE SHALL BE CLASS "A" OR "C".

OF 200 PSF/FT DEPTH.

PRESSURE, OR BEARING AREA INDICATED ON THE DRAWINGS USING A PASSIVE RESISTANCE THAN 1500 PSF AT THE TOP OF THRUST BLOCK WHEN THE PIPE IS SUBJECTED TO ITS TEST

1. BEARING AREA IS THE AREA REQUIRED TO OBTAIN A MAXIMUM PRESSURE NOT GREATER NOTES:

AGAINST UNDISTURBED SOIL

OBTAIN BEARING AREA
LENGTH "L" AS REQUIRED TO
-

A TYPICAL SECTION
A
-
A
-
A
-
FORCE
THRUST

DOME CAP
POST

TERMINAL

CORNER OR
BARS

STRETCHING
FABRIC
MESH

POST CAP
FRAME
PIPE

HINGE CLIP
LATCH
DROP

PER PLAN

CONCRETE SLAB
CAP

LINE POST

END CLAMP

HINGE CLAMP

GATE POST

CORNER POSTS

TERMINAL GATE AND

BRACES AT

GATE POST

LINE POST

BOTTOM WIRE
STAKES @ 6'-0" OC

COMPACTED ABC

AC PAVING

FINISH GRADE
1/2"
5/8"Ø x 1'-6" STEEL GRADE
SEE NOTE 1.

HEADER BOARDS.

SMALLER RADIUS, USE 2 - 1 x 8
EDGES AND LARGE RADIUS. FOR
2 x 8 HEADER BOARD AT STRAIGHT
NOTES:

1. HEADER BOARD MATERIAL SHALL BE EITHER PRESSURE TREATED DOUGLAS FIR OR REDWOOD.

PERSONNEL GATE DETAIL

AT CONC

PAVEMENT

V-TYPE BARBED WIRE ARM
6 STRAND BARBED WIRE

BARBED WIRE CORNER ARM
~

FABRIC MESH

CHAIN LINK
8'-0
"
FG
BAR

STRETCHER
WIRE

TENSION

TENSION WIRE

CENTERLINE TOP RAIL OR

BARBED WIRE FRAME GATE BARBED WIRE
POST

SLIDING

SLEEVE ROD
TRUSS
ROD

TENSIONING
ROD

TENSIONING
LATCH
POST
GATE

TENSION WIRE

TOP RAIL OR

CORNER POST

BRACE (TYP)

DIAGONAL

CONCRETE FENCE POST FOUNDATION

MAX MAX
(SEE NOTE 4)

CHAIN LINK FENCE DETAIL

CHAIN LINK GATE DETAILS
P
lotD
ate: 9-S
E
P
-2025 10:57:47
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:16:53-07'00'

Page 1496 of 1832 ends

L
TYP
08/22/22
CY257
SN SHEET 1 OF 5

STEEL PIPE - CONNECTION TO EXISTING PCCP
TYP
08/22/22
CY257
SN SHEET 2 OF 5

STEEL PIPE - CONNECTION TO EXISTING PCCP
TYP
11/27/18
CY257
SN SHEET 3 OF 5
TYP
08/22/22
CY257
SN SHEET 3 OF 5

STEEL PIPE - CONNECTION TO EXISTING PCCP
TYP
08/22/22
CY257
SN SHEET 4 OF 5

STEEL PIPE - CONNECTION TO EXISTING PCCP
TYP
08/22/22
CY257
SN SHEET 5 OF 5
STEEL PIPE - CONNECTION TO EXISTING PCCP CY481
TYP
09/05/18

DIP TEST BULKHEAD
S SHEET 2 OF 2
CY481
TYP
09/05/18

DIP TEST BULKHEAD
S SHEET 1 OF 2
TYP
12/26/18
CY301 STEEL PIPE - PASS HOLE DETAIL
S
2'-0
"
CE
CE
DGB
TC02
46 TYPICAL DETAILS
CIVIL 2
201631-100000 201631TC02.dgn
gleal

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
1/4

CLAMP AND DIP

BRONZE SERVICE

TAPE BETWEEN

POLYETHYLENE
20-MIL

WAX TAPE

WRAP WITH
IPT, 0-600 PSI (V-30)
WITH MALE IPT x FEMALE

BRONZE BALL VALVE
JOINT x MALE IPT, 0-300 PSI

COPPER SOLDER

COPPER ADAPTER,
STRONG, IPT, 2" LONG.

RED BRASS NIPPLE, EXTRA
OUTLET.

WITH FEMALE IPT

SERVICE SADDLE

DUCTILE IRON
OUTLET.

WITH FEMALE IPT

SERVICE SADDLE

DUCTILE IRON

ASSEMBLY SIZE INSULATING BUSHING
2-1/2"
1-1/2"

OUTLET SIZE
1-1/2" 2"
2"
1"
2" x 1-1/2"
2-1/2" x 2"
1-1/2" x 1"
1-1/2"
2"

VALVE SIZE
1"
TACK WELD AT 4 LOCATIONS

PIPE TO REMAIN PIPE TO BE REMOVED

COIL BACK REMAINING

CONNECTED WIRE

EXISTING
AWWA C303 PIPE
STEPS 1-3
STEPS 5-6
9" 3"

CL OF CUT
STEP 4
STEPS 7-11

BUTT STRAP

SEE REPAIR DETAILS
SHEETS 3 AND 4

BUTT STRAP INSTALLATION SEQUENCE

PER DRAWINGS

NEW STEEL PIPE

BUTT STRAP INSTALLATION SEQUENCE
1 DETERMINE LENGTH "L" OF PIPE TO BE REMOVED AND MARK ON PIPE. 2 BE CONTACTED IMMEDIATELY.

GREATER THAN SHOWN IN THE DETAIL, THE OWNER AND ENGINEER ARE TO MINIMUM DISTANCE. IF THE CONTRACTOR REQUIRES COATING REMOVAL BE REMOVED 3" FROM THE MARKED POINT. THE DIMENSIONS ARE A

TO REMAIN, THEN CHIP OFF THE COATING OF THE PORTION OF THE PIPE TO CAUTIOUSLY CHIP OFF THE COATING 9" FROM THE MARKED POINT OF PIPE 3 MARK THE CUT LOCATION ON THE EXPOSED BAR WRAPPED CYLINDER. 4 STEP DESCRIPTION
CIRCUMFERENTIAL WRAPS OF THE PIPE TO REMAIN 6" FROM THE CUT MARK.

TACK WELD EXPOSED WIRE ALONG A HORIZONTAL LINE ON FOUR
5 WIRE NOT STILL CONNECTED TO THE REMAINING CYLINDER WRAP.

CUT CYLINDER AND WIRE WRAP ALONG MARK AND REMOVE PIPE AND ANY 6 OF FIELD APPLIED COATING.

CEMENT MORTAR LINING IN PREPARATION FOR WELDING AND PLACEMENT COIL BACK PORTION OF UNTACKED WIRE WRAP. CHIP BACK EXISTING 7 PLACE NEW CONNECTING PIPE AND INSTALL BUTT STRAP AND WELD. 8 AIR TEST BUTT STRAP JOINT PER CONTRACT DOCUMENTS.
9 MORTAR LINE THE INSIDE BOTTOM OF THE BUTT STRAP.
10 BUTT STRAP OVERLAP AND TACK WELD.

PULL TAUGHT THE REMAINING BAR WRAP (STEP 6) BACK TO WITHIN 1" OF 11 WELDED WIRE FABRIC HELD 3/8" FROM STEEL .

WRAPPED CYLINDER IN ACCORDANCE WITH AWWA C303 USING 2x4x13 GA

PLACE CEMENT MORTAR COATING OVER BUTT STRAP AND EXPOSED BAR

SPIGOT RING CONNECTION DEMOLITION
NOTE 4 GASKET
WIRES

PRE-STRESSED
HIGH TENSION NOTE 3

RESTRAINING HEX BOLTS
NOTE 2

SPIGOT RING

BELL RING

PCCP TO REMAIN

CONTRACT DRAWINGS

BUTT STRAP PER

CONTRACT DRAWINGS

WELD BUTT STRAP PER

STEEL PIPING

PROPOSED

APPLIED LINING

APPLIED LINING SHOP
FIELD

PRE-STRESSED WIRES

HIGH TENSION
WIRE MESH (NOTE 5)

SPIGOT RING BUTT STRAP CONNECTION
SHIM (NOTE 9)

BUTT STRAP

BE REMOVED

PCCP TO

PER CONTRACT DRAWINGS

PROPOSED STEEL PIPE
PIPING (NOTE 5)

BUTT STRAP AND EXPOSED

MORTAR DIAPER OVER
NOTE 7

BELL RING CONNECTION
NOTE 2

SPIGOT RING
NOTE 6
GASKET

PCCP TO REMAIN
WIRE MESH (NOTE 5)
NOTE 8
SHIM (NOTE 9)

BE REMOVED

PCCP TO

HEX BOLTS

RESTRAINING
WIRES

PRE-STRESSED

HIGH TENSION
STRAP AND EXPOSED PIPING (NOTE 5)

MORTAR DIAPER OVER BUTT

DETERMINED IN FIELD

WELD DIMENSION TO BE
WIRES

PRE-STRESSED

HIGH TENSION

DETERMINED IN FIELD

WELD DIMENSION TO BE

STEEL PIPE
NEW

APPLIED LINING
FIELD

APPLIED LINING
SHOP

BELL RING CONNECTION DEMOLITION
PCCP BUTT STRAP INSTALLATION NOTES:

9. SHIM THICKNESS TO BE DETERMINED BASED ON FIELD OBSERVATIONS.

OBSERVATIONS.

CONTRACTOR SHALL DETERMINE PLUG SIZE AND THREADING BASED ON FIELD PLUG HOLE WITH NICKEL PLATE BRASS HEX SOCKET PLUG AFTER TESTING.

8. CONTRACTOR TO LEAVE ONE BOLT HOLE OPEN FOR AIR TESTING.

7. PLUG WELD EXISTING BOLT HOLES ENTIRE THICKNESS OF EXISTING BELL RING.

DAMAGE REMAINING SPIGOT RING.

AND SLIDE PIPING SPIGOT RING OUT OF BELL RING TAKING CARE NOT TO

REMOVE GAP SECTION, UNBOLT RESTRAINING HEX BOLTS AT BOTH ENDS,

CIRCUMFERENCE IN CENTER OF STICK AT TWO PLACES TO CREATE A GAP, PROTECT EXISTING BELL RING IN PLACE. TO REMOVE PCCP STICK, CUT PIPING

6. REMOVE ENTIRE STICK OF PCCP, RESTRAINING HEX NUTS, AND SPIGOT RING.

AS REQUIRED.

WELDED WIRE FABRIC HELD 3/8" FROM STEEL. REPAIR INTERIOR LINING WRAPPED CYLINDER IN ACCORDANCE WITH AWWA C304 USING 2x4x13 GA

5. PLACE CEMENT MORTAR COATING OVER BUTT STRAP AND EXPOSED BAR FOR WELDING.

SPIGOT RING. GRIND SPIGOT RING PLAIN END SMOOTH IN PREPARATION

4. CHIP AWAY INTERIOR LINING AS REQUIRED AND CUT GASKET SEAT FROM DAMAGE REMAINING SPIGOT RING.

AND SLIDE PIPING BELL RING OFF OF SPIGOT RING TAKING CARE NOT TO

GAP, REMOVE GAP SECTION, UNBOLT RESTRAINING HEX BOLTS AT BOTH ENDS,

PIPING CIRCUMFERENCE IN CENTER OF STICK AT TWO PLACES TO CREATE A PROTECT EXISTING SPIGOT RING IN PLACE. TO REMOVE PCCP STICK, CUT

3. REMOVE ENTIRE STICK OF PCCP, RESTRAINING HEX NUTS, AND GASKET.

2. CHIP AWAY MORTAR DIAPER AT BELL CONNECTION.

TO TAKE CARE NOT TO DAMAGE EXISTING HIGH TENSION PRE-STRESSED WIRES.

TO FABRICATION OF BUTT STRAP, BUTT STRAP SHIMS, AND SHIM. CONTRACTOR

1. CONTRACTOR TO FIELD VERIFY DIMENSIONS OF SPIGOT RING AND BELL PRIOR NOTES:

UNLESS ACCESS THROUGH MANWAY IS AVAILABLE.

1. PASS HOLE EVERY 300-FEET ON CONTINUOUS WELDED SECTIONS,

ELEVATION

SQUARE HEAD PLUG

FIELD PLACED MORTAR

THREAD-O-LET

MORTAR (TYP)

SHOP PLACED
6X2 REDUCER
150# GV

BLOCKING

TEMPORARY

PROVIDE

DIP FLANGE
CLASS 54 MIN
t

DRILL TO MATCH DIP FLANGE
STEEL FLANGE AWWA C207

SYSTEM CONNECTION

INSTALLATION OF

OVER FLANGES DURING

WAX TAPE COATING

REQUIRED

VALVES AS
6" DRAIN WITH
OUTLET

SYSTEM CONNECTION

INSTALLATION OF

ENCASEMENT DURING

POLYETHYLENE

PROTECT
SECTION VIII, DIV 1.

PRESSURE VESSELS

CODE, UNFIRED

PRESSURE VESSEL

BY ASME BOILER AND

CALCULATE THICKNESS
STEEL BULKHEAD.

SEMI-ELLIPSOIDAL

HEMISPHERICAL OR

REQUIRED

VALVES AND CAP AS
3" AIR VENT WITH

INFILTRATION

TO PREVENT WATER

PIPE AND TAPE ENDS

TIGHTLY AGAINST
ENCASEMENT. WRAP
8-MIL POLYETHYLENE
THICKNESS.

FOR MINIMUM
PIPE. SEE SPECS

DUCTILE IRON
0-300 PSI

INSULATING BUSHING,

PLASTIC OR NYLON

HYDROSTATIC TESTING

SEAL WELD PRIOR TO
P
lotD
ate: 9-S
E
P
-2025 10:57:3
3 P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:18:07-07'00'

Page 1497 of 1832 ends

6 "
M
IN
TR
EN
C
H
6" MINIMUM (TYP)
"X" + 4" MIN
"X"
TYP
10/20/20
CY716
S

GATE VALVE - DIRECT BURY

OFFSET AS SHOWN ON PLANS

RECESSED LOCK
1'-4"
1'-4
"
3 "
3"
1'-4"
1'-4
"
3 "
3"
CY745
TYP
08/22/22

AIR/VACUUM VALVE ASSEMBLY - ABOVE GRADE
SN
CY745
TYP
09/13/22

AIR/VACUUM VALVE ASSEMBLY - ABOVE GRADE
R

AS REQD
2'-0
"
2'-0
"
A
S
R
E
Q
D
TYP
CY715
R SHEET 1 OF 2 08/29/23

BUTTERFLY VALVE - DIRECT BURY

AS REQD
1'-0
" 1'-0
"
VAR
IE
S
TYP
CY715
R SHEET 2 OF 2 08/29/23

BUTTERFLY VALVE - DIRECT BURY
CY745
TYP
09/13/22

AIR/VACUUM VALVE ASSEMBLY - ABOVE GRADE
R
1'-0" MIN
MIN
1'-0"
CY745
TYP
08/22/22

AIR/VACUUM VALVE ASSEMBLY - ABOVE GRADE
SN
MP100
MP100
CE
CE
DGB
TC03
47 TYPICAL DETAILS
CIVIL 3
201631-100000 201631TC03.dgn
ALaico

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
16 TYP
TYP
TYP
TYP
TYP
TYP
TYP
TYP
16 4. VALVE TYPE AS INDICATED ON THE DRAWINGS.

3. CLEAN VALVE BOX OF ALL DEBRIS AND SOIL.

2. COAT BURIED PIPE AND VALVE BOX AS SPECIFIED.

ROTATION TO OPEN VALVE.

SQUARE AWWA NUT WITHIN 36" OF VALVE BOX COVER. NUT IS TO INDICATE DIRECTION OF

1. ALL BURIED VALVES SHALL BE PROVIDED WITH EXTENSION STEM OPERATION WITH 2" NOTES:

W
ID
TH
PLAN

UNDISTURBED SOIL

SECTION
DIA = VALVE BOX ID MINUS 1/8"

VALVE STEM EXTENSION

VALVE SUPPORT

VALVE ENDS FOR TYPE

OF PIPE INSTALLED
CLASS "C" CONCRETE
1/4" THICK STL TRASH RING. RING

RUBBER VALVE BOX TOP HAT

PAVED UNPAVED

CENTERED
#5@12" EW
3 SQ FT x 8" CLASS A CONC PAD

SERVICE STAMPED ON LID

BEDDING

BOTTOM OF TRENCH

BEDDING

PAVEMENT
5 4
2 1
3 7
14 12
15 6
8 9
13 5
4 8
9 10
7 11
12 (TYP)

DIP PIPING

AC PAVEMENT

ELEVATION

PROFILE DWGS

SEE PLAN AND
1 B
FIN GR
VAR
IE
S
2 "
2%MINIMUM

SLOPEUP
NOTES:

PANEL
22 GA GALVANIZED

METAL COVER
1-1/2" #9 EXPANDED

CONSTRUCTION
MIN 14 GA STEEL

OR EQUAL
E1A-PWW ENCLOSURE

PLACER WATERWORKS
3" 24" L x 36" W x 36" H

VALVE SIZE ENCLOSURE SIZE

4. SIZE BOX APPROPRIATELY PER TABLE.

RECESSED LOCK.

3. ENCLOSURE SHALL INCLUDE A
CORNER (4 TOTAL).

BOLT TABS. ONE ANCHOR IN EACH

TO CONCRETE PAD USING INTEGRAL

2. ENCLOSURE SHALL MOUNT SECURELY
(DFT 6-8 MILS).

ANTI-GRAFFITI CHEMISTRY TOP COAT
MILS ZINC RICH PRIMER WITH 4-5 MILS
BLAST) AND POWDER COATED WITH 2-3
BLASTED (SSPC SP-5 WHITE METAL

1. ALL SURFACES SHALL BE ABRASIVE

ITEM DESCRIPTION
REMOVABLE GUARDPOST. SEE TYPICAL DETAIL CF161.

CONCRETE ANCHOR BLOCK, 24" SQ. MINIMUM BEARING AREA.

SURFACE ABOVE GRADE. SEE TYPICAL DETAIL MP544.

FLOOR AND SLAB PENETRATION, EXTEND COATING FOR BURIED
3" GROOVED COUPLING.

POLYETHYLENE ENCASEMENT PER AWWA C105. BOND ALL JOINTS. 3" DIP WITH RESTRAINED JOINTS AND CEMENT MORTAR LINING WITH GOOSENECK PIPED TO FLOOR.
2" COMBINATION AIR RELEASE AND AIR VACUUM VALVE WITH 180° 2" BRASS GATE VALVE.

VALVE.
3" DUAL BODY COMBINATION AIR RELEASE VALVE AND VACUUM
AIR VALVE ENCLOSURE.
6" THICK CONCRETE PAD WITH #4 @ 12" EW REINFORCEMENT BARS. 3" 90° MJ x MJ ELBOW.
3" 90° FLG x MJ ELBOW.
3" FLANGED RESILIENT SEATED GATE VALVE.

INSTALL CONCRETE COLLAR IN NON-TRAFFIC AREAS.

VALVE SEE TYPICAL DETAIL CY716.

VALVE BOX INSTALLATION FOR BURIED
1 FLANGE OUTLET.
2 3
4 5
6 10
7 8
9 11
12 13
14 15
16 PROFILE DWGS

SEE PLAN AND
PLAN
2 B
-
A
(TYP OF 4)
NOTES:

PROFILE DWGS

SEE PLAN AND
PLAN
CONNECTIONS BETWEEN DISSIMILAR METALS.

4.PROVIDE FLANGE INSULATING JOINT OR DIELECTRIC FITTING AT

3. ALL MJ FITTINGS SHALL BE FULLY RESTRAINED.

2. CONNECTION PIPING SHALL BE THE SAME SIZE AS THE AIR/VACUUM VALVE.

1. LOCATE AIR VALVES AS SHOWN ON PLANS
2 B
-
A
(TYP OF 4)

3. CLEAN VALVE BOX OF ALL DEBRIS AND SOIL.

2. COAT BURIED PIPE AND VALVE BOX PER SPECIFICATIONS.

ROTATION TO OPEN VALVE.

SQUARE AWWA NUT WITHIN 36" OF VALVE BOX COVER. INDICATE ON NUT DIRECTION OF

1. ALL BURIED VALVES SHALL BE PROVIDED WITH EXTENSION STEM OPERATOR WITH 2" NOTES:

SHEET 2 OF 4
FOR 3/8" STUDS

TAB WITH HOLES

ANCHOR BOLT
FRAME
DOOR
STEEL
HINGES

INTERNAL
SHEET 3 OF 4

OF STEEL BODY

BONDED TO INSIDE

INSULATION
MINIMUM R-8
MINIMUM 25 SQ IN

ALONG BASE FOR

GAP SPACE

CONTINUOUS AIR
MINIMUM 3/8"

DIMENSIONS
PLAN

PIPELINE

TRANSMISSION
WATER
CL
VALVE

BUTTERFLY
SLAB

CONCRETE

CONCRETE PAD

VALVE BOX AND

CL STATION
CLSM

BUTTERFLY VALVE
12" ABC

ELEVATION
DIA = VALVE BOX ID MINUS 1/8"
1/4" THICK STL TRASH RING. RING

PAVED UNPAVED

CENTERED
#5@12" EW
3 SQ FT x 8" CLASS A CONC PAD

SERVICE STAMPED ON LID

FINISHED GRADE
2 "

BOX TOP HAT

RUBBER VALVE

EXTENSION

VALVE STEM

CONCRETE SLAB

ACTUATOR
VALVE
#5@12" T&B EW

BACKFILL

PAVEMENT
SHEET 4 OF 4
(TYP)
(TYP)
SHEET 1 OF 4

VALVE BODY

SHALL NOT REST ON
CI VALVE BOX. BOX
5 1/4" DIA. SLIP TYPE
TYP
(TYP)

PIPE SUPPORT

CONCRETE

TYP PIPE SUPPORT

CONCRETE

VALVE BODY

SHALL NOT REST ON
CI VALVE BOX. BOX
5 1/4" DIA. SLIP TYPE
P
lotD
ate: 9-S
E
P
-2025 10:5
8:52
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:16:41-07'00'

Page 1498 of 1832 ends

CITY
CITY
DGB
TC04
48 TYPICAL DETAILS
CIVIL 4
201631-100000 201631TC04.dgn
ALaico

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
P
lotD
ate: 9-S
E
P
-2025 10:59:49
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:16:28-07'00'

Page 1499 of 1832 ends

6 "
M
IN 12
" 12
"
EG001

COMPRESSION CONNECTION

GROUND ROD AND GROUNDWELL
S
TYP
TYP
S
EL507
S101
A
-
-
B
-
B
-

A SECTION SECTION

NON-TRAFFIC AREAS

POLE FOUNDATION
TYP
S
EA070

TO CONCRETE WALL

PREFORMED CHANNEL ATTACHMENT
C
LR
2 "
M
IN
DRAWINGS (NOTE 3)

REFER TO STRUCTURAL

REINFORCEMENT (TYP)

CONCRETE WALL

PREFORMED CHANNEL
REQUIRED (TYP) (NOTE 2)

ANCHORS, NUTS, AND LOCKWASHER AS
(NOTE 2)
MAX
INTERMEDIATE Z FITTINGS AT 3'-0" O.C.

WHERE LENGTH EXCEEDS 3'-0" PROVIDE
U.O.N. (TYP)
TYP
S
EG101 COPPER GROUNDING CABLE CONNECTION

TYP COMPRESSION CONNECTION
S
EG002 GROUND ROD

COMPRESSION CONNECTION
CE
CE
JGB
TE01
49 TYPICAL DETAILS
ELECTRICAL 1
201631-100000 201631TE01.dgn
nself

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

FINISHED GRADE

DIAMETER AS SPECIFIED)

GROUND ROD (LENGTH AND

BACKFILL
SOIL
1 DRAIN ROCK
OR IN SPECIFICATIONS.

SIZE AS INDICATED ON DRAWINGS

GROUND GRID CONDUCTOR

GROUND WELL AS SPECIFIED
# KEY NOTES:

ROD AND CABLE PER CONNECTOR MANUFACTURERS GUIDELINES.

1. GROUND ROD TO GROUND GRID CROSS CONNECTOR. SIZE FOR
GENERAL NOTES:

POLE

CONDUIT
GRADE

SST ANCHOR BOLTS,

NUTS, LOCK WASHERS,

AND LEVELING NUTS PER

ELEVATION

COMPACTED SOIL

CONCRETE
CLASS "A"
SEE

LAP SPLICE

POLE BASE

CONC PIER
L
POLE

FINISHED
COVER

POLE BASE

CONDUIT(S)

ELECTRICAL

ENCASED
GROUT
MIN 1" NON-SHRINK

1. SEE NOTE
6-#5 MIN.

LAP SPLICE @ TOP SPIRAL.
#3 SPIRAL MIN. SEE NOTE 1.

TYP
S
E
E
N
O
TE 1.
5'-0
"
M
IN
6 "
P
ITC
H
P
ITC
H
3 @
3 "
2 "
C
LR
P
ITC
H
O
F
S
P
IR
AL
4"
MIN
2'-0
"
M
IN
3"CL
B
R
OLT
ANCHOR
C
MIN
8"
3 "
C
LR
2'-0"D
IA
M
IN
S
E
E
N
O
TE 1
S
E
E
N
O
TE 1
2'-0
"
D
IA
M
IN
INCREASE DIMENSIONS AS REQUIRED.

OTHERWISE NOTED. PROVIDE WIND LOAD CALCULATIONS AND

1. USE MINIMUM DIMENSIONS AND REINFORCEMENT SHOWN UNLESS

POLE MFR REQUIREMENTS
A
S
R
E
Q
U
IR
ED
GRADE

FINISHED
1 OR IN SPECIFICATIONS.

SIZE AS INDICATED ON DRAWINGS
GROUND GRID CONDUCTOR.
3'-0" (MIN)
SOIL
# KEY NOTES:

CONNECTOR MANUFACTURERS GUIDELINES.

1. GROUND GRID CROSS CONNECTOR. SIZE FOR CABLE PER

DIAMETER AS SPECIFIED)

GROUND ROD (LENGTH AND
GRADE

FINISHED
1 OR IN SPECIFICATIONS.

SIZE AS INDICATED ON DRAWINGS
GROUND GRID CONDUCTOR.
3'-0" (MIN) SOIL
# KEY NOTES:

ROD AND CABLE PER CONNECTOR MANUFACTURERS GUIDELINES.

1. GROUND ROD TO GROUND GRID CROSS CONNECTOR. SIZE FOR
GENERAL NOTES:

3. REFER TO STRUCTURAL DRAWINGS FOR ORIENTATION OF REINFORCEMENT AND BARS.

SHALL BE PER THE SPECIFICATIONS.

2. SUPPORTS TO BE SPACED IN ACCORDANCE WITH NEC REQUIREMENTS. CONCRETE ANCHORS

1. THIS DETAIL TYPICAL FOR BOTH VERTICAL AND HORIZONTAL MOUNTING.

P
lotD
ate: 9-S
E
P
-2025 10:59:19
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by John G. Briones
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.11 15:41:54-07'00'

Page 1500 of 1832 ends

S
EM001 REINFORCED CONCRETE DUCT BANK
1 4
2 3
2 4
5 TYP
1 6
6 6 7
8 2
3 9
5 INDICATED ON THE DRAWINGS.

WIRE UNLESS OTHERWISE
#4/0 SDBC GROUND

GROUND WIRE
SDBC

CLASS CE CONCRETE (RED)

FINISHED GRADE
(TYP
)

3.0 "
(TYP)

3.0"
TYP
S
EM015 DIRECT BURIED CONDUIT OR CABLE
3" (TYP)
3 "
4 "
2'-6
"
12 "
TYP
S
EM020 DUCT BANK RISER
1 EM001
EM001
TYP
R
EM032
08/23/2023
EM001
EM001
EM107
(TYP
)"
18 "

DUCT BANK RISER
S
EM070 ENCASED CONDUITS AT MANHOLES OR
1 2
4 3
EM001
S130
S180

TYP STRUCTURES - W/O WATERSTOP
CE
CE
JGB
TE02
50 TYPICAL DETAILS
ELECTRICAL 2
201631-100000 201631TE02.dgn
nself

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
12"
24"
BELOW
GRADE (MIN)"
CONCRETE PLACEMENT & CURING.

3. MAKE PROVISIONS TO PREVENT CONDUIT FLOTATION DURING
CONDUITS.

SECTIONS, AND CONDUIT SCHEDULE FOR NUMBER AND SIZE OF
NUMBER OF CONDUITS WITHIN DUCT BANK. REFER TO DUCT BANK

THE DUCT BANK SPECIFICATION TO ACCOMMODATE ACTUAL

2. ADJUST SIZE OF DUCT BANK BASED UPON THESE GUIDELINES AND

1. DIMENSIONS SHOWN ARE MINIMUM.
#
AT BOTH ENDS OF THE DUCT BANK.

9. BOND THE DUCT BANK GROUND WIRE TO THE GROUNDING SYSTEM PROVIDES 1'-4" VERTICAL LEGS EACH SIDE.

8. LOWER PORTION OF TIES COULD BE U-BARS IF UPPER PORTIONS OF HORIZONTAL TIE.

7. CONTRACTOR'S OPTION TO PROVIDE 1'-4" LAP LENGTH EACH SIDE SHALLOWER THAN 21"

6. 1'-4" OR 135 DEGREE HOOK FOR SHALLOW DUCT BANKS
CONDUIT REQUIREMENTS.

5. REFER TO DUCT BANK SECTIONS AND SPECIFICATIONS FOR
FROM TIES.

4. PVC CONDUIT SPACERS ON 8'-0" CENTERS (MAXIMUM). LOCATE 12" 24" TO REDUCE DEFLECTION.

DUCT BANK. PROVIDE PRECAST BAR SUPPORTS AT INTERVALS OF

UNDER A TIE AT EACH PVC CONDUIT SPACER ALONG LENGTH OF

3. MINIMUM OF TWO PRECAST CONCRETE BAR SUPPORTS PLACED
LENGTH OF DUCT BANK.

2. #4 REINFORCING STEEL TIES MAXIMUM 24" ON CENTER ALONG PERIMETER OF DUCT BANK.

1. #4 REINFORCING STEEL 12" MAXIMUM ON CENTER AROUND ENTIRE GENERAL NOTES:

KEY NOTES:

FINISHED GRADE

BACKFILL

WARNING TAPE

SAND BACKFILL

CONDUIT OR CABLE

DIRECT BURIED
GENERAL NOTES:

REQUIREMENTS.

2. REFER TO THE SPECIFICATIONS FOR TRENCH BACKFILL
THE DRAWINGS.

1. ALL DIMENSIONS ARE MINIMUM UNLESS OTHERWISE INDICATED ON #4@12"
#4 U-SHAPED BARS

LAP SPLICE
(TYP)
TYP
TYP
3" CLR COVER
DRAWINGS.

ON THE

AS INDICATED

DUCT BANK

CONTINUING
KEY NOTES:

GENERAL NOTES:

1. REFER TO THE SPECIFICATIONS FOR MATERIAL REQUIREMENTS. #
EQUIPMENT ABOVE.

1. ADJUST DUCT SPACING TO FIT OPENING IN THE SLAB AND
#4@12"
#4 U-SHAPED BARS

LAP SPLICE
(TYP)
GRADE

SLAB ON
1 3" CLR COVER
TYP
TYP
TYP
CONTINUING DUCT BANK AS INDICATED ON THE DRAWINGS.

KEY NOTES:

GENERAL NOTES:

1. REFER TO THE SPECIFICATIONS FOR MATERIAL REQUIREMENTS. #
WHERE THE CONDUIT IS NOT PROTECTED BY AN EQUIPMENT PAD.

1. PROVIDE CONDUIT HOUSE KEEPING CURB AT ALL LOCATIONS

CONDUIT(S)

OUTSIDE OF

STRUCTURE

INSIDE OF

DUCTBANK)
1" (TYP AROUND

STIRRUPS

STRUCTURE

FITTING (TYP)

END BELL

CONDUCTOR

GROUNDING

REINFORCEMENT

LONGITUDINAL
TYP
TYP
TYP
# KEY NOTES:

REINFORCEMENT PER
REQUIRED. FOR CAST-IN-PLACE STRUCTURES, PROVIDE

4. PROVIDE ADDITIONAL REINFORCEMENT AROUND OPENING AS
ALTERNATE WITH TYPICAL REINFORCEMENT FOR 6" SPACING.

3. ADDITIONAL #4 x 12'-0" @ 12" ON ALL FOUR FACES OF ENCASEMENT.

HEIGHT IN INCHES.

SPACING IN INCHES = (H-4)/2 WHERE H = CONCRETE ENCASEMENT

2. FOR FIRST 12'-0" FROM INSIDE FACE OF STRUCTURE, STIRRUP CONDUCTOR.

MANHOLE. BOND GROUNDING FITTING TO DUCTBANK GROUNDING

1. PROVIDE GROUNDING FITTING FOR METALLIC CONDUITS ENTERING P
lotD
ate: 9-S
E
P
-2025 10:5
8:3
7 P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by John G. Briones
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.11 15:42:35-07'00'

Page 1501 of 1832 ends

TYP
S
EM105 SPARE CONDUIT DETAIL
A
-

ELEVATION
-
C
C
-

SECTION
C
-
TYP
S
EM202 DEVICE SUPPORT AND MOUNTING
B
-

ELEVATION
4'-0" MAX
1'-6" SQ
3 "
1 1/2" (TYP)
EM
B
ED
M
EN
T
2'-6
"
M
IN
4-#5
#3 @ 6"
GROUT
1" NON-SHRINK
BOLTS
ANCHOR 3/4 x 12 x 12
AL PL
5 SQ
GROUT
1" NON-SHRINK
AL 5 SQ x 0.250 WALL
3/8 AL PL
1/2" RADIUS (TYP)

ROUND CORNERS TO
1/4 AL PL

TYP DEVICE
5'-0
"
M
AX
6'-6
"
M
AX
3"
3 -1/2
"
TYP
R
EM107 CONDUIT HOUSEKEEPING CURB
08/23/2023
2 1
FLOOR

FINISHED

TO FLOOR

DOWEL CURB

CHAMFER

CONDUIT
#3 HOOP
DRAINAGE.

TOP OF CURB FOR

CROWN OR SLOPE

STEEL CONDUIT

PVC COATED
(TYP)

CONDUIT COUPLING
(TYP
)"
12 "
EM001

TYP MOUNTING DETAIL
NP122 PRESSURE TRANSMITTER
S
TYP
S
EM315 SUBMERSIBLE EQUIPMENT

CABLE CONNECTION DETAIL
4 "
6 "
M
IN
EM001
EM070
(TYP)
TYP
EM056

PRECAST CONCRETE W/HATCH

ELECTRICAL HANDHOLE
S
C
-

ELEVATION
-
A
B
-

SECTION
-
C
1'-4" SQ
3 "
10"
1"(TYP)
3/8
"
6 "
C
-

SECTION
EM201
S
TYP

DEVICE SUPPORT AND MOUNTING
CE
CE
JGB
TE03
51 TYPICAL DETAILS
ELECTRICAL 3
201631-100000 201631TE03.dgn
nself

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
3 2 2
1 ENCASED CONDUITS

EXPOSED CONDUITS

WASHER OR HEX NUT

CONDUIT CAP

NYLON PULL ROPE

NUT TO PIPE CAP

WELD WASHER OR HEX
STEEL CONDUIT.

PVC COATED RIGID
STEEL COUPLING.

PVC COATED RIGID

WASHER OR HEX NUT

TIE PULL ROPE TO
CURB

OR HOUSEKEEPING

FINISHED FLOOR
GENERAL NOTES:

1. PROVIDE 2" MIN CLEAR BETWEEN ADJACENT CONDUITS

STEEL CONDUIT

PVC COATED RIGID

WITH THE CURB

COUPLING BOOT FLUSH

CUT PVC COATING
COATED CONDUITS.

EXTEND SPARE

CAN BE USED TO

SEALING LOCKNUT

RIGID STEEL

AND PVC COATED

MAY BE REMOVED

IN FUTURE, PLUG
PLUG.

BRASS CONDUIT
CL
CL
CL
1/4
1/4
1/4
GENERAL NOTES:

4. WEIGHT OF DEVICE(S) SHALL NOT EXCEED 300 POUNDS.

3. USE STAINLESS STEEL FASTENERS FOR MOUNTING DEVICES.

SPECIFICATIONS.

2. COAT ALUMINUM SURFACES IN CONTACT W/ CONCRETE PER

1. USE ELEVATION B WHERE A SEPARATE FOUNDATION IS REQUIRED. # KEY NOTES:

TYP

2. COORDINATE REINFORCING STEEL REQUIREMENTS WITH THE CONTRACTOR.

1. TYPICAL BOTH SIDES, FRONT AND REAR.

PIPE CAP
1/4" GALVANIZED STEEL FLOOR
FLOOR
PIPE

PROCESS
1" S.S. PIPE NIPPLE
PIPE. w/ANCHOR BOLTS
CL

BELOW CENTER LINE OF PROCESS PIPE

MOUNT PRESSURE TRANSMITTER

FLEXIBLE CONDUIT
1/4" S.S. TUBING
1/4" S.S. TUBING
1/2" MALE CONNECTOR FOR
1" TO 1/2" S.S. REDUCER
1" S.S. WELDOLET
1" S.S. UNI-BODY BALL VALVE

MOUNTING
BRACKET FOR 2" PIPE
MOUNTING PLATE. WELD TO
6 7
8 9
11 10
9 3
1 2
12 5
4 12
11 10
9 8
7 6
5 4
3 2
1 NOTES:

SPECIFICATIONS

PRESSURE TRANSMITTER AS PER
#
GENERAL NOTES:

KEY NOTES:

ENCLOSURES.

3. DO NOT MAKE CONDUIT CONNECTIONS TO THE TOP OF NEMA 4X AND CONTROL BLOCKS.

2. PROVIDE A BACK PANEL AND DIN RAIL FOR MOUNTING THE POWER REQUIREMENTS.

1. REFER TO THE SPECIFICATIONS FOR ENCLOSURE AND MATERIAL JUNCTION BOX AS REQUIRED.

4. PROVIDE CONDUIT SEALS ON THE BUILDING WIRE SIDE OF THE WET WELL. REFER TO THE DRAWINGS.

3. THE EQUIPMENT CABLE MAY BE ROUTED IN CONDUIT FROM THE

2. PROVIDE CLEARANCE IN ACCORDANCE WITH THE NEC.

1. LISTED POWER TERMINAL BLOCKS WITH SAFETY COVER.

SUBGRADE

PREPARED
GRADE

FINISHED
PANEL

KNOCKOUT

PRE-FORMED
HATCH

ACCESS ROADWAY

COATING

EXTERIOR

DRAIN SUMP

GROUND ROD
3/4" x 10'-0"

PULLING IRON (TYP)
1 6
3 5
8 4
2 MAX
6"

MATERIAL
BASE 9
(TYP 4 SIDES)
12" MIN
TYP
TYP
#
GENERAL NOTES:

KEY NOTES:

COURSE.

9. BASE MATERIAL: PROVIDE MIN 12" COMPACTED AGGREGATE BASE

8. PROVIDE ONE PULLING IRON ON EACH WALL OF HANDHOLE.

FOR CONNECTION REQUIREMENTS.

7. GROUNDING CABLE CONNECTION. REFER TO THE SPECIFICATIONS HANDHOLE.

6. MAXIMUM TOP SLAB OVERHANG IS TYPICAL AROUND 4 SIDES OF PROOFING.

5. COAT EXTERIOR WALLS BELOW GRADE WITH BITUMINOUS DAMP BASE MATERIAL BELOW.

MINIMUM 18" SQUARE FILTER FABRIC TO ISOLATE GRAVEL FROM THROUGH FLOOR OF HANDHOLE. SET SUMP OPENING OVER

4. PROVIDE MINIMUM 4 INCH DIAMETER, GRAVEL FILLED PENETRATION WALL AROUND HANDHOLE.

PREFORMED KNOCKOUT PANELS. PROVIDE KNOCKOUTS ON EACH

3. INSTALL DUCT BANKS ONLY THROUGH CAST-IN OPENINGS OR
SPECIFICATIONS FOR CONNECTION REQUIREMENTS.

2. BOND DUCT BANK GROUND CABLE TO GROUND ROD. REFER TO THE LOAD RATING OF HATCH.

1. SEE THE MANHOLE AND HANDHOLE SCHEDULE FOR REQUIRED
BANKS AT EACH HANDHOLE.

3. SEE DRAWINGS FOR ORIENTATION, NUMBER, AND SIZE OF DUCT USING #4 AWG BARE COPPER CABLE.

2. BOND ALL METALLIC ITEMS INSIDE HANDHOLE TO GROUND ROD ELECTRICAL HANDHOLE AND MANHOLE SCHEDULE.

1. PROVIDE MINIMUM INTERIOR DIMENSIONS AS SHOWN IN THE
AL CS6 x 4.03
ROUND CORNERS TO 1/2"
4'-6
"
M
AX
CL

CONC ANCHORS
1" NON-SHRINK
GROUT

RADIUS (TYP)
#3 @ 6"
4 - #5
1/4
TO
C
EN
TER
O
F
D
EV
IC
E
GROUT
1" NON-SHRINK

ANCHORS
EM
B
ED
M
EN
T
2'-6
"
M
IN
AL PL
5/8"
GENERAL NOTES:

4. WEIGHT OF DEVICE(S) SHALL NOT EXCEED 100 POUNDS.

3. USE STAINLESS STEEL FASTENERS FOR MOUNTING DEVICES.

SPECIFICATIONS.

2. COAT ALUMINUM SURFACES IN CONTACT WITH CONCRETE PER

1. WHERE SEPARATE FOUNDATION IS REQUIRED, SEE SECTION B. 7 KELLEMS GRIP

EQUIPMENT CABLE
4 P
lotD
ate: 9-S
E
P
-2025 10:5
8:54
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by John G. Briones
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.11 15:42:19-07'00'

Page 1502 of 1832 ends

SIZE PER DWGS

COUPLING, MALE NPT,

FEMALE QUICK

ANGLE VALVE W/

HOSE END BRONZE
AS REQ'D.

REDUCER
(SEE NOTE 2)

PVC SLEEVE

NON-METALLIC
FLOOR

PIPE CLAMP
MP253

DWGS & SPECS

PIPE, PER
FLOOR
3'-0" ABOVE

GATE VALVE
BRONZE

SEE PLANS HOSE END
FOR CONT.

S542
S542
MP256
TYP
12/01/22
MA417
S SHEET 1 OF 2

WASHDOWN - HOSE RACK
TYP
S SHEET 1 OF 2 08/03/23
MP003
B
2 CONCRETE ENCASEMENT - BELOW STRUCTURE
TYP
MP003
S 08/03/2023

CONCRETE ENCASEMENT - BELOW STRUCTURE
TYP
09/14/23
MA415
R

WASHDOWN - HOSE BIBB
2'-6
"
5'-0
"
3'-0
"
2'-6
" 1'-2
"
2 WALLS)

WALL ABOVE (TYP
MATCH THICKNESS OF 12" (TYP 2 WALLS)
#5 @ 12" (TYP)
2'-6"
3'-6"
1'-2"R
8"R
8"
3 1/4" (TYP)
1"
1/8
1/8
1'-6
"
TYP
J 05/17/23
MA112 SUBMERSIBLE SUMP PUMP
1'-2"R
8"R
6 "
10"
4'-0
"
1'-2"R
8"R
1/4
TYP
1'-6
"
3'-6"
3'-6"
1'-6
"
TYP
12/01/22
MA417
S SHEET 2 OF 2

WASHDOWN - HOSE RACK
A
-
B
-
A
1 FORMED ENCASEMENT
NOTE 5
O
R
FO
R
M
EN
C
A
S
EM
EN
T
S
N
O
TE
5 6"
0 "
O
R
FO
R
M
ED
EN
C
A
S
EM
EN
T
3" CLR

WIDTH OF TRENCHED
8" MIN ALONG PIPE
12 "
M
IN
CE
CE
DGB
TM01
52 TYPICAL DETAILS
MECHANICAL 1
201631-100000 201631TM01.dgn
gleal

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444

5. SPLICE PERIMETER REINFORCEMENT OUTSIDE INTERSECTION OF ENCASEMENT WHERE POSSIBLE.

4. ENCASEMENT CONCRETE: CLASS A-NA.

POLYETHYLENE SHEETING.

TROWEL TOP SURFACE AND SEPARATE ENCASEMENT FROM STRUCTURE WITH 2 LAYERS 6 MIL SECTION IS LESS THAN 12", EXTEND ENCASEMENT UPWARD TO UNDERSIDE OF SLAB. STEEL

3. WHERE DISTANCE BETWEEN BOTTOM OF STRUCTURE AND TOP OF TYPICAL ENCASEMENT

2. TERMINATE CONCRETE ENCASEMENT AT A PIPE JOINT OUTSIDE OF THE STRUCTURE.

1. PIPE MATERIAL AND PIPE JOINTS / COUPLERS AS INDICATED ON THE DRAWINGS.

NOTE:

CHANNEL

SUPPORT TYP
6 "
*
3'-0
"
* OR AS NOTED ON PLANS
~
TYP
TYP
TYP
SHEET 2 OF 2
NOTES:

2. SLEEVE REQUIRED FOR DISSIMILAR METALS.

1. INSTALL HOSE RACK, MA417/TYP AT EACH HOSE VALVE.
#5 @ 6" EW

CUT AND BAND GRATING

AL GRATING

AROUND PIPING
PLAN

PIPE SUPPORT

PUMP (TYP)

SUBMERSIBLE SUMP

REINFORCEMENT

WALL ABOVE

BAR SIZE AND

SPACING SHALL

MATCH BARS IN
3" PIPE
#5 @ 6" EW

SLAB REINF (TYP)

FOR SLAB

SEE DRAWINGS
3" PV (TYP)
3" UNION (TYP)

LAP SPLICE
-
A
A
-

SECTION
#5 @ 12" EW H2E
3" CV (TYP)
3"Ø x 12" RUBBER

FLEX CONN (TYP)

LAP SPLICE WITH TOP
(TYP 2 WALLS)
#5 @ 12" EW EF
(TYP 2 WALLS)
#5 @ 12" EF

SHOW A SMALLER PIPE DIAMETER

INSTALL REDUCER IF DRAWINGS

1. UNLESS OTHERWISE INDICATED, PIPE SHALL BE SCH80 PVC.

NOTES:

RACK

GUARDRAIL MOUNTED

TOP OF CONC

U-BOLTS
-
A
A
-

SECTION
3-8
3-8

AL OR SST GUARDRAIL

3. WALL MOUNTED HOSE RACKS ON MASONRY WALL SHALL BE FASTEN TO GROUTED CELLS.

LONG x 2'-0" WIDE x 12" DEEP CONCRETE PAD WITH #5@12" EW, T&B.

2. HOSE RACKS INSTALLED IN YARD LOCATIONS SHALL BE FREESTANDING. ANCHOR TO A 4'-6" SMOOTH.

1. HOSE RACK SHALL BE FABRICATED FROM 3/16" ALUMINUM PLATE. ROUND ALL EDGES NOTES:

RACK
RACK

CONCRETE OR

MASONRY WALL
1" NON-SHRINK

GROUT (TYP)
-
B
-
B

WALL MOUNTED

SECTION
AL CS6 x 4.03

NUT, AND WASHER (TYP)
AL CS6 x 4.03 (TYP)

FREE STANDING
1/2" AL PL
2" (TYP)
2"
1" (TYP)
1/2"Ø SST CA (TYP)
1/2"Ø SST CA (TYP)
1/2"Ø SST CA (TYP)

SECTION

VERTICAL RISER BELOW STRUCTURE

HOOK (TYP) PIPE

ACI STD
& CLEARANCES IN SEC A/1

MATCH MIN DIMENSIONS
#4
TIE
S
@
2'-0
"
- TURNED DOWN)

ACI STD HOOK (TYP

LAP SPLICE
H
E
IG
H
T
O
F
TR
EN
C
H
ED

ENCASEMENT
- AT TOP OF HORIZ
& INSIDE TYP REINF
#5X4'-0" DIA ES PIPE

AT STRUCTURE

TOP OF ENCASEMENT

SEE DRAWINGS
(OPT)

CONST JT

RISER REINF

TO MATCH VERT
VERT
REINF

LONGITUDINAL

TO MATCH
HORIZ
NOTE 3
MIN
#4@2'-0"
#4@2'-0"
MIN 1 EA CORNER
CONT #5@2'-0" OC ES
PIPE 36" DIA & SMALLER:

UNO ON DRAWINGS:

LARGEST OD
NOTE 1

INDICATED ON DRAWINGS

BACKFILL W/ BASE MATL
B.O. STRUCTURE
M
IN
M
IN
H
E
IG
H
T
O
F
TR
EN
C
H
ED
LAR
G
E
S
T
O.D.
(TYP)

OR FORMED ENCASEMENT
(TYP)

PIPE FOUNDATION
MIN 1 EA CORNER
CONT #6@2'-0" OC ES
PIPE LARGER THAN 36" DIA:

ON DRAWINGS

BASE MATERIAL INDICATED
N
O
TE
3 6
"
M
AX
3 "
M
IN
B.O. STRUCTURE

PREPARED SUBGRADE
FABRIC

STABILIZATION

CL SYMM

PLACE FILL AS SHOWN
12" OR MORE BELOW STRUCTURE:

TOP OF ENCASEMENT

EXTEND ENCASEMENT TO STRUCTURE
THAN 12" BELOW STRUCTURE:

TOP OF ENCASEMENT LESS
6 "
ALO
N
G
P
IP
E
6 "
P
lotD
ate: 9-S
E
P
-2025 10:5
8:09
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:17:47-07'00'

Page 1503 of 1832 ends

"C"
1 1/2" (TYP)
"D
"

PROVIDE CLAMP WITH SUPPORT
ROUND ALL SHARP CORNERS TO 1/2" RADIUS
"B" SCHEDULE 40 STL PIPE
MAX DIMENSION SHOWN. USE STRAIGHT THREADS

LENGTH AND THREADS TO ALLOW MIN AND
"A" SCHEDULE 40 STL PIPE
SQ 3/4" PL
1" NON-SHRINK GROUT

ANCHORS
4 - 3/4"Ø SST CONC
MP034
TYP
12/01/22
PIPE SUPPORT - POST ON CONCRETE: ADJUSTABLE

HEIGHT STEEL W/ TOP SADDLE
NS
"D
"
2" (TYP)
"D"/4
"D"/4
9"
TYP
12/01/22
MP100
N SHEET 1 OF 2

PIPE SUPPORT - CONCRETE CRADLE
PIPE OD + 6"
1 1/2"
3" (TYP)
TYP
12/01/22
MP256
N

SWAY BRACE

PIPE SUPPORT - WALL - VERTICAL PIPE ON CLAMP
TYP
09/15/23
MP253
CHANNEL: SURFACE MOUNTED

PIPE SUPPORT - PREFORMED
R
2'-0
"
12 "
TYP
12/01/22
MP100
N SHEET 2 OF 2

PIPE SUPPORT - CONCRETE CRADLE
CE
CE
DGB
TM02
53 TYPICAL DETAILS
MECHANICAL 2
201631-100000 201631TM02.dgn
ALaico

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444

3. = NOMINAL PIPE SIZE.

2. = USE 2 1/2" SUPPORTS FOR PIPES LESS THEN 2 1/2"Ø.

1. HOT-DIP GALVANIZED SUPPORT AFTER FABRICATION.

NOTES:
2 1/2 2 1/2 1 1/2
PIPE

SUPPORTED

SIZE OF
**
"A"

PIPE SIZE
"B"
PIPE SIZE "C"
"D"

MINIMUM MAXIMUM
(INCHES)

ADJUSTABLE PIPE SADDLE SUPPORT SCHEDULE
*
12 8 13
3 2 1/2 1 1/2 12 8 1/2 13 1/2
3 1/2 2 1/2 1 1/2 12 8 1/2 13 1/2
4 3 2 1/2 12 9 1/2 14
6 3 2 1/2 12 10 1/2 15 1/2
8 3 2 1/2 12 11 1/2 16 1/2
10 3 2 1/2 12 13 1/2 18 1/2
12 3 2 1/2 12 15 19 1/2
14 4 3 12 16 1/2 20 1/2
16 4 3 12 17 1/2 22 1/2
18 6 3 1/2 14 19 1/2 24
20 6 3 1/2 14 21 25 1/2
24 6 4 14 23 1/2 28 1/2
30 6 4 14 27 31 1/2
32 6 4 14 28 1/2 32 1/2
36 6 4 14 30 1/2 34 1/2
1/4
*
**
1/8" THICK 40 DUROMETER
ANCHOR BOLTS. SEE SCHEDULE

STRUCTURE

SUPPORT FOOTING

OR STRUCTURE
#4 EF
FOR SIZE.

STRAP. SEE SCHEDULE
1" NON-SHRINK GROUT
NEOPRENE PAD. BOND TO
PAINTED PIPE WITH EPOXY.
-
B
B
-
-
A

SECTION

SECTION-SUPPORT AT STRUCTURE
FOR SIZE. 12" MINIMUM EMBEDMENT.
6 x BOLT DIA WITH 3" MINIMUM
#4 TIES @ 12"
#5 @ 12" EF H1E
6" MIN

MASONRY WALL

CONCRETE OR GROUTED
BENT FB 3/8 x 1 1/2
x LENGTH REQUIRED
WALL
OD/2 + 1"

PIPE OR FLANGE

LOCK WASHERS (TYP)
45° (TYP)
DRAWINGS.

MATERIAL SHALL BE HOT-DIP GALVANIZED STEEL UNLESS OTHERWISE INDICATED ON THE STRUCTURE, ALL MATERIAL SHALL BE STAINLESS STEEL. IN ALL OTHER AREAS, ALL

1. IF SUPPORT IS SUBMERGED OR LOCATED BELOW THE TOP OF WALL IN WATER BEARING NOTE:
(TYP)
1/2"Ø BOLTS WITH
1/2"Ø CONC ANCHOR

ELEVATION

PIPE SIZE AND MATERIAL

PIPE STRAP

PREFORMED CHANNEL

PIPE SUPPORT
BOLTS
ANCHOR
-
A
A
-

AS INDICATED ON THE DRAWINGS

SECTIONAL PLAN

2. SEE SECTION 15062 FOR ADDITIONAL REQUIREMENTS.

DRAWINGS. HOT-DIP GALVANIZE AFTER FABRICATION.

MATERIALS SHALL BE HOT-DIP GALVANIZED STEEL UNLESS OTHERWISE INDICATED ON THE STRUCTURE, ALL MATERIAL SHALL BE STAINLESS STEEL. IN ALL OTHER AREAS, THE

1. IF SUPPORT IS SUBMERGED OR LOCATED BELOW THE TOP OF WALL IN WATER BEARING NOTES:

FINISH GRADE
FB 1/4" x 4"
FB 5/16" x 4"
FB 3/8" x 4"
6" ABC
#4 TIES @ 12"
-

C SECTION-ISOLATED
#4 @ 10" EW T&B
"W".

SEE NOTE 2.

SCHEDULE

2. THE WIDTH OF THE FOOTING "W" = 2'-6". THE LENGTH OF THE FOOTING = "D" + 2'-0".

GALVANIZED STEEL UNLESS OTHERWISE INDICATED ON THE DRAWINGS.

OTHER AREAS, THE MATERIAL FOR ANCHOR BOLTS AND STRAP SHALL BE HOT-DIP STRUCTURE, MATERIAL FOR ANCHOR BOLTS AND STRAP SHALL BE STAINLESS STEEL. IN ALL

1. IF SUPPORT IS SUBMERGED OR LOCATED BELOW THE TOP OF WALL IN WATER BEARING NOTES:

SUPPORT WITH FOOTING
8" - 12"
14" - 24"
26" - 36"
1/2"
5/8"
3/4"
SIZE
PIPE
SIZE
STRAP

BOLT DIA
ANCHOR
P
lotD
ate: 9-S
E
P
-2025 10:5
8:18
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Page 1504 of 1832 ends

TYP
12/01/22
MP544
NS
S180
1"
-
A
-
B
SHEET 1 OF 2

W/ BARRIER SEALS

WALL PENETRATION - CAST-IN SLEEVE
TYP
12/01/22
MP544
NS SHEET 2 OF 2

W/ BARRIER SEALS

WALL PENETRATION - CAST-IN SLEEVE
-
A
-
B
CE
CE
DGB
TM03
54 TYPICAL DETAILS
MECHANICAL 3
201631-100000 201631TM03.dgn
ALaico

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
No. 78444
TYP

MANUFACTURER)

SLEEVE (BY SEAL

SEAL (TYP)

FINISHED FLOOR MODULAR MECHANICAL

MANUFACTURER)

SLEEVE (BY SEAL
SEAL (TYP). NOTE 1.

MODULAR MECHANICAL
SLEEVE.

1. WALLS THICKER THAN 12" INSTALL MODULAR MECHANICAL SEAL AT BOTH ENDS OF WALL NOTES:

WALL PENETRATION
NEW

SLAB PENETRATION
NEW

SEAL (TYP)

FINISHED FLOOR MODULAR MECHANICAL
SEAL (TYP). NOTE 2.

MODULAR MECHANICAL
CORE DRILL. NOTE 1.

CORE DRILL. NOTE 1.

PENETRATION.

2. WALLS 12" OR THICKER INSTALL MODULAR MECHANICAL SEAL AT BOTH ENDS OF OD.

MODULAR MECHANICAL SEAL MANUFACTURER'S RECOMMENDATIONS FOR SPECIFIC PIPE

1. CORE DRILL DIAMETER. PROCEDURES, AND POST -DRILLING SURFACE PREPARATION PER NOTES:

WALL PENETRATION

EXISTING

SLAB PENETRATION

EXISTING
P
lotD
ate: 9-S
E
P
-2025 10:59:42
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by Justin C. Peterson
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 13:17:22-07'00'

Page 1505 of 1832 ends

TYP
S 03/12/19
S101 REINFORCED CONCRETE NOTES
SHEET 2 OF 3
TYP
S 03/12/19
S101 REINFORCED CONCRETE NOTES
SHEET 3 OF 3
TYP
S107 PREFABRICATED PVC WATERSTOP JOINTS
TYP
S 07/11/16
S110 CONSTRUCTION JOINT
0 "
0 "
SHEET 1 OF 2
NOTE 5
NOTE 5
TYP
S102 CIRCULAR WALLS - HORIZONTAL REINFORCEMENT

LAP SPLICES
S 03/19/19
TYP
S 03/12/19
S101 REINFORCED CONCRETE NOTES
SHEET 1 0F 3
TYP
S 07/11/16
S110 CONSTRUCTION JOINT
0 "
MIN 9"
E
Q
E
Q
12 "
U
N
O
0 "
"T
"/2
"T
"
MIN 9"
SHEET 2 OF 2
NOTE 5
NOTE 5
TYP
S106 PVC WATERSTOP SCHEDULE
"A"
"B"
"D"
"C"
CE
CE
JAD
TS01
55 TYPICAL DETAILS
STRUCTURAL 1
201631-100000 201631TS01.dgn
JB
aum
barger

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
SPLICE SHALL BE IN CONTACT WITH EACH OTHER.

WHEN MULTIPLE BARS ARE SPLICED AT THE SAME SECTION, THE "CLEAR D.

C.

B.

FORMED VERTICAL CONCRETE SURFACES.............................2"

11. LAP SPLICES:

D. FOOTINGS AND SLABS ON GRADE:

OR CONCRETE WORK MATS.......................................................3"

AT UNFORMED CONCRETE SURFACES CAST AGAINST SOIL, ROCK,
TOP SURFACE OF FOOTINGS AND SLABS................................SAME AS SLABS

8. WATERSTOPS:

A SLAB WITHOUT WATERSTOPS, CONTINUE WATERSTOP TO WALL/SLAB JOINT. WHERE B. END WATERSTOPS 3" BELOW TOP OF WALLS. WHERE TOP OF WALL IS COVERED BY

TOP OF WALL IS COVERED BY A SLAB WITH WATERSTOPS, MAKE WATERSTOPS ADEQUATE SYSTEMS TO PROVIDE WATER CURING WHERE REQUIRED.

10. DO NOT PLACE BACKFILL AGAINST WALLS UNTIL:

HAS REACHED THE MINIMUM SPECIFIED COMPRESSIVE STRENGTH (f'c).

BAR SPACING" IS DEFINED AS THE MINIMUM CLEAR DISTANCE BETWEEN THE BARS OUTSIDE THE SPLICE LENGTH MINUS ONE BAR DIAMETER.
"TOP BARS" ARE HORIZONTAL REINFORCEMENT AT LOCATIONS WHERE MORE

9. CURE CONCRETE IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. WHERE WATER CURING IS SPECIFIED, MEMBRANE CURING IS NOT ALLOWED.

A. THE CONTRACTOR IS WARNED THAT WATER CURING IS DIFFICULT AT TIMES DUE TO WIND AND DRY CONDITIONS. STUDY SPECIFICATION REQUIREMENTS AND FURNISH B. KEEP WATER CURED SURFACES VISIBLY MOIST AT ALL TIMES. FLOOD TOPS OF WALLS NOT LESS THEN 3 TIMES DAILY.

ELEMENTS HAS REACHED THE MINIMUM SPECIFIED COMPRESSIVE STRENGTH (f'c).

B. CONNECTING SLABS AND BEAMS HAVE BEEN CAST AND CONCRETE IN THOSE

12. FORM EXPOSED CONCRETE CORNERS AND EDGES WITH 3/4" CHAMFER UNLESS A. PROVIDE WATERSTOPS AT JOINTS IN SLABS AND WALLS OF LIQUID-CONTAINING CONTINUOUS, SPLICING WATERSTOPS IN WALLS WITH WATERSTOPS IN SLAB.

A. WALLS HAVE BEEN CAST TO FULL HEIGHT OF STRUCTURE AND CONCRETE

UNLESS OTHERWISE INDICATED ON THE DRAWINGS, BARS AT A LAP THAN 12 INCHES OF FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE BAR.

OTHERWISE INDICATED ON THE DRAWINGS.

STRUCTURES, AND PORTIONS OF STRUCTURES BELOW THE DESIGN GROUNDWATER LEVEL. MAKE WATERSTOPS CONTINUOUS THROUGH STRUCTURE, SPLICING A.

WATERSTOPS IN SLABS WITH WATERSTOPS IN WALLS.

SEE TABLE 1 OF THIS DETAIL FOR LAP SPLICE LENGTHS.
#4 MORE THAN 2
MORE THAN 2
#11
MORE THAN 2
MORE THAN 2
#10
#9
MORE THAN 2
MORE THAN 2
#8
#7
MORE THAN 2
MORE THAN 4
#6
#5
43 33
62 56
50 48
42 38
30 26
20 24
20 16
MORE THAN 1
MORE THAN 2
MORE THAN 1
MORE THAN 2
MORE THAN 1
MORE THAN 2
MORE THAN 1
MORE THAN 2
MORE THAN 1
MORE THAN 2
MORE THAN 1
MORE THAN 1
MORE THAN 1
MORE THAN 4
MORE THAN 4
MORE THAN 4
MORE THAN 4
MORE THAN 4
MORE THAN 4
MORE THAN 2
MORE THAN 2 MORE THAN 4 69 54
MORE THAN 2
MORE THAN 2
*
* *
114 88
*
*
*
*
*
*
*
81 70
62 54
37 31
25 104
*
*
*
*
*
*
32 *
40 48
70 81
90 BAR
SIZE

LAP SPLICE LENGTH (INCHES)

TOP BARS OTHER BARS
(BAR DIA)

BAR SPACING

MINIMUM CLEAR
(BAR DIA)
COVER

MINIMUM
TABLE 1: REINFORCING BAR LAP SPLICES: f'c = 4000 PSI, Fy = 60,000 PSI INCREASED BY 50 PERCENT.

COVER IS LESS THAN OR EQUAL TO ONE BAR DIAMETER, THE LAP SPLICE LENGTH SHALL BE

2. = IF THE CLEAR BAR SPACING IS LESS THAN OR EQUAL TO TWO BAR DIAMETERS, OR THE MINIMUM COVER AND FOR MINIMUM CLEAR BAR SPACING ARE SATISFIED.

1. TABULATED SPLICE LENGTHS ARE APPLICABLE ONLY WHEN BOTH REQUIREMENTS FOR REINFORCING BAR LAP SPLICE TABLE NOTES:

BOND BOND
BOND
BOND

VERTICAL CROSS
EXPANSION JOINT.

EXPANSION JOINT
MANUFACTURER. FIELD WELDS SHALL BE BUTT WELDS ONLY.

2. CROSSES AND TEES SHALL BE FACTORY PREFABRICATED BY THE MANUFACTURER'S RECOMMENDATIONS.

1. MAKE WELDS AS SPECIFIED AND IN ACCORDANCE WITH THE
NOTES:

CROSS TEE

IN-PLANE JOINTS
CROSS

TEE WALL TO FOOTING AT EXPANSION JOINT

OUT-OF-PLANE JOINTS
07/08/16

VERTICAL / WALL

HORIZONTAL / SLAB
JOINT

SLAB CONSTRUCTION

WALL TO FOOTING /

NON-WATER BEARING WALL OR SLAB

SINGLE LAYER REINFORCEMENT

NON-WATER BEARING WALL OR SLAB

DOUBLE LAYER REINFORCEMENT

CL CONSTRUCTION JOINT

CL CONSTRUCTION JOINT
BARS @ "S" 2 1/2"2 1/2" BARS @ "S"
BARS @ "S" 2 1/2" 2 1/2" BARS @ "S"

THROUGH JOINT

CONTINUE REINF
REINF WHERE "S" > 8"

TYP SPACING OF
_
REINF WHERE "S" < 8"

TYP SPACING OF
NOTE 2
(TYP
)

THROUGH JOINT

LAP SPLICE CONTINUE REINF
NOTE 2 NOTE 3
(TYP
)
LAP SPLICE NOTE 3
NOTE 2
DETAIL
THIS

FIGURES

TYP FOR ALL
4" 4"
L
L
L
WALL

CIRCULAR

REINF (TYP)

CIRCUMFERENTIAL
NOTE2
(TYP)
(TYP)

SPLICE LENGTH

TOP BAR LAP
NOTE 3
(TYP)

C LAP SPLICE

C LAP SPLICE
(TYP)
NOTE2
NOTE 4.

JOINT. SEE

CONSTRUCTION
WALL

5. SHOP-BEND HORIZONTAL BARS TO RADIUS OF WALL.

LAYOUT RESULTING FROM NOTES 2 AND 3.

4. STAGGER BAR PROJECTIONS PAST VERTICAL CONSTRUCTION JOINT TO MAINTAIN THAN EVERY THIRD BAR.

3. AT EACH FACE OF WALL, LAP SPLICES SHALL NOT COINCIDE IN VERTICAL ARRAYS MORE SPLICE LENGTH, BUT NOT LESS THAN 3 FEET.

2. AT EACH FACE, STAGGER ADJACENT LAP SPLICES BY AT LEAST ONE TOP BAR LAP STRUCTURES USING TOP BAR LAP SPLICES.

1. LAP SPLICE HORIZONTAL REINFORCEMENT IN CIRCULAR WALLS OF LIQUID-CONTAINING NOTES:

C LAP SPLICE
FORMED CONCRETE SURFACES FOR DRY CONDITIONS:

FORMED CONCRETE SURFACES EXPOSED TO WEATHER,
STIRRUPS AND TIES................................................2"

FORMED CONCRETE SURFACES EXPOSED TO WEATHER,
FORMED CONCRETE SURFACES FOR DRY CONDITIONS:

C. WALLS:

B. BEAMS AND COLUMNS:

FORMED CONCRETE SURFACES AND UNFORMED TOP SURFACES

7. 6.

5. EXPOSED TO WEATHER, IN CONTACT WITH SOIL OR FLUIDS,

3. 2.

1. A. SLABS AND JOISTS:
#7 BARS AND SMALLER..........................................1" #8 BARS AND LARGER............................................1 1/2" #8 BARS AND LARGER............................................1 1/2" #7 BARS AND SMALLER..........................................1" PRINCIPAL REINFORCEMENT................................2 1/2" PRINCIPAL REINFORCEMENT................................2" STIRRUPS, SPIRALS, AND TIES..............................1 1/2" SEE DIVISION 03 SPECIFICATION FOR REQUIREMENTS FOR CONCRETE CONSTRUCTION.

WALL REINFORCEMENT AT CORNERS OR JUNCTIONS OF WALLS SHALL BE CONTINUOUS, OR LOCATED OVER FLUIDS..........................................2"

IN CONTACT WITH SOIL OR FLUIDS, OR IN BEAMS LOCATED
OVER FLUIDS:

OR IN CONTACT WITH SOIL OR FLUIDS.......................2"

SLAB, BEAM AND COLUMN REINFORCING BARS SHALL HAVE A MINIMUM EXTENSION OR ANCHORAGE INTO SUPPORTS IN ACCORDANCE WITH ACI 318 AND ACI 350.

DISPLACEMENT AS REQUIRED.

UNLESS OTHERWISE INDICATED ON THE DRAWINGS, CONCRETE COVER OVER #11 AND SMALLER REINFORCING BARS SHALL BE AS FOLLOWS:

FORMED CONCRETE SURFACES AND UNFORMED TOP SURFACES FOR DRY CONDITIONS

UNLESS OTHERWISE INDICATED ON THE DRAWINGS, MINIMUM REINFORCEMENT OF CONCRETE WALLS OR SLABS SHALL BE AS FOLLOWS. CONTACT ENGINEER FOR LOCATIONS INSIDE CONCRETE.

MORE THAN 10" THICK: ..........................................#5 @ 12" EACH WAY, EACH FACE.

PROVIDE STIRRUP SUPPORT BARS SHALL BE TO SECURE TOP BARS AGAINST 10" THICK OR LESS: ................................................#5 @ 12" EACH WAY.

4. UNLESS OTHERWISE INDICATED ON THE DRAWINGS, DOWELS BETWEEN ADJACENT CONCRETE

PLACEMENTS SHALL BE THE SAME SIZE AND SPACING AS THE REINFORCEMENT WHICH IS SPLICED TO THE DOWELS.

LAP SPLICED, OR TERMINATED IN AN ACI STANDARD 90 DEGREE HOOK. SEE DETAIL S144/TYP.

LAP SPLICE

LAP SPLICE (TYP)
NOTES:

1. 2.

3. 4.

WATER BEARING SLAB OR WALL
WATER BEARING SLAB LESS THAN 12" THICK
1 1/2 1 1/2
1 CL CONSTRUCTION JOINT
NOTE 2
NOTE 3
NOTE 4
(TYP
)
NOTE 4 NOTE 3

CL CONSTRUCTION JOINT
(TYP
)

THROUGH JOINT

CONTINUE REINF
JOINT EDGES:

A. FOR WALLS AND BOTTOM OF EXPOSED SLABS: FORM EDGES WITH 1/2" CHAMFER.

B. FOR SLABS: EDGE TOP AND ENDS WITH 1/4" RADIUS.
"T" EQUALS SLAB OR WALL THICKNESS.
"S" EQUALS TYPICAL BAR SPACING INDICATED ON THE DRAWINGS. 1 NOTE 2

CONTINUE REINF THROUGH JOINT

5. STOP REINFORCING 2" CLEAR OF JOINT.

PLACING CONCRETE.

WATER-BLAST EXPOSED JOINT FACE AND PROJECTING REINFORCEMENT BEFORE PLACING CONCRETE IN SECOND POUR.

HOG RINGS MAY BE USED IN LIEU OF WIRE LOOPS. THOROUGHLY CLEAN WATERSTOP BEFORE 6" WATERSTOP CENTERED ON JOINT - SEE DETAIL S106/TYP. PROVIDE WIRE TIES MAX 2'-0" OC. "E" = NUMBER OF
RIBS PER SIDE "F"
(MINIMUM)

2. DIMENSIONS ARE MINIMUM, UNLESS OTHERWISE NOTED.

1. SEE SPECIFICATIONS FOR MATERIAL REQUIREMENTS.

NOTES:

R 6/17/24
3/8"
3/8"
1" 3/8"
3/8" -
1/4"
7 7
TYPE "B" "C" "D" "E" "F"
2" 3/8" 3/8" 7 1/4"
-
9"
"A"
9"
6"

APPLICATION

CONSTRUCTION AND

EXPANSION JOINTS
1" AND NARROWER

EXPANSION JOINTS

TENSION/COMPRESSION

CONTROL JOINTS
WIDER THAN 1" AND

RING BEAM AT DIGESTERS

W/O CENTER BULB

CENTER BULB

CENTER BULB
P
lotD
ate: 9-S
E
P
-2025 10:5
8:03
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:29:45-07'00'

Page 1506 of 1832 ends

TYP
03/12/19
S140
SHEET 2 OF 2

CONSTRUCTION JOINT - WALLS
S, N
TYP
03/12/19
S142
0 "
LAP
S
P
LIC
E
0 "
(TYP
)

CONSTRUCTION JOINT - WALLS AT ELEVATED SLABS
S,N SHEET 2 OF 3
TYP
S 07/22/16
S130
SHEET 1 OF 2
"W" SEE PLANS AND NOTE 3 FOR JOINT WIDTH

EXPANSION JOINT
TYP
S 07/22/16
S130
SHEET 2 OF 2
MIN 9"
"W"
MIN 9"
"W" SEE PLANS AND NOTE 3 FOR JOINT WIDTH
12 "
U
N
O
E
Q
S
LAB
E
Q
2" CLR (TYP)

EXPANSION JOINT
TYP
03/12/19
S142
0 "
4" MAX
0 "
(TYP
)

CONSTRUCTION JOINT - WALLS AT ELEVATED SLABS
S, N SHEET 1 OF 3
TYP
03/12/19
S140
SHEET 1 OF 2
LAP
S
P
LIC
E
LAP
S
P
LIC
E
0" (TYP AT LAPS)
LAP
S
P
LIC
E
0" (TYP AT LAPS)
LAP
S
P
LIC
E

CONSTRUCTION JOINT - WALLS
S, N
TYP
03/12/19
S142 CONSTRUCTION JOINT - WALLS AT ELEVATED SLABS
S,N SHEET 3 OF 3
LAP
S
P
LIC
E
LAP
S
P
LIC
E
LAP
S
P
LIC
E
CE
CE
JAD
TS02
56 TYPICAL DETAILS
STRUCTURAL 2
201631-100000 201631TS02.dgn
JB
aum
barger

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
2" CLR (TYP)
2" CLR (TYP)

1. "S" EQUALS TYPICAL BAR SPACING INDICATED ON THE DRAWINGS.

2. PLACE AND ALIGN BARS BEFORE PLACING DOWELS. BAR SIZE TO MATCH SLAB BARS.

3. WATER-BLAST JOINT FACE AND PROJECTING REINFORCEMENT BEFORE PLACING CONCRETE.

4. 5.

6. 7.

8. BEFORE PLACING CONCRETE.

HOG RINGS MAY BE USED IN LIEU OF WIRE LOOPS. THOROUGHLY CLEAN WATERSTOP 6" PVC WATERSTOP CENTERED VERTICALLY ON JOINT. PROVIDE WIRE TIES MAX 2'-0" OC.

NOTES:

10. 9.

DOWELS: SAME SIZE AND SPACING AS VERTICAL WALL BARS, UNLESS OTHERWISE NOTED. (SEE SPECIFICATIONS.)
PLACE CEMENT GROUT OVER JOINT FACE IMMEDIATELY BEFORE PLACING CONCRETE.

HOOK WHERE REQUIRED BY SLAB THICKNESS.)
WATERSTOP AT TOP SURFACE OF JOINT AND CENTERED BETWEEN VERTICAL BARS.

WHERE DRAWINGS INDICATE "W/ STRIP WSTP" PROVIDE LOW EXPANSION HYDROPHILIC CONSTRUCTION JOINT WHERE INDICATED ON THE DRAWINGS.

DRAWINGS

INDICATED ON THE

SPACING AS

REINF SIZE AND

WALL AND SLAB
NOTE 6
B
AR
S
AT
"S
"
4 "
4 "
NOTE 6
NOTE 9
T.O. SLAB
NOTE 5
NOTES 3 & 4
SPLICE
LAP
NOTE 5
NOTES 3 & 4
NOTES 3 & 4
NOTE 8
NOTE 8
NOTE 8
NOTES 3 & 4
NOTE 6
NOTE 2
NOTE 9
NOTE 8
NOTE 8
NOTES 3 & 4
T.O. SLAB

OF WALL

SLABS AT BOTTOM
S140/TYP FOR

SEE DETAIL
(TYP)
NOTE 2
(TYP)
NOTES 3 & 4
NOTE 2 (TYP)
3 "
3 "
NOTE 2 (TYP)
NOTE 8
NOTE 11

JOINT MATERIAL

JOINT MATERIAL
SEE NOTE 4
SEE NOTE 4 A
-
B
-
B
-
A
-

CL EXPANSION JOINT

CL EXPANSION JOINT

CL WALL OR SLAB

NON-WATER BEARING SLAB OR WALL

WATER BEARING SLAB OR WALL
(TYP EA FACE)
(TYP EA FACE)
EXPANSION NOTE 1.

WATERSTOP.

EXPANSION
1 1/2
1 1
1 1/2
A
-
B
-
WATER BEARING SLAB LESS THAN 12" THICK
TH
IC
KN
E
S
S
DETAIL

SUBGRADE
-
B
-
A

CL EXPANSION JOINT

TO SUBGRADE

JOINT MATERIAL

EXTEND EXPANSION
WATERSTOP. NOTE 1.

DETAIL

JOINT MATERIAL

EXPANSION
MORE THAN 1/2"
THAN 1/4" & NOT

NOT LESS
"W" /2 BUT

RUBBER FILLER

SYNTHETIC SPONGE
GAP
MIN 1/4"

JOINT MATERIAL

EXPANSION
SURFACE.

CONCAVE
TOOLED
SEE SPECS.

JOINT SEALANT
LOCATIONS.

4. USE DETAIL A ONLY AT SOIL SIDE OF SLABS ON GRADE. USE DETAIL B AT ALL OTHER (MIN JOINT WIDTH = 3/8". MAX JOINT WIDTH = 2")

3. "W"=1" UNLESS OTHERWISE INDICATED ON PLANS.

B. FOR SLABS: EDGE TOP AND ENDS WITH 1/4" RADIUS.

A. FOR WALLS AND BOTTOM OF EXPOSED SLABS: FORM EDGES WITH 3/4" CHAMFER.

2. JOINT EDGES:

THOROUGHLY CLEAN WATERSTOP BEFORE PLACING CONCRETE IN SECOND POUR.

PROVIDE WIRE TIES MAX 2'-0" OC. HOG RINGS MAY BE USED IN LIEU OF WIRE LOOPS.

1. 9" WATERSTOP WITH CENTER BULB CENTERED ON JOINT - SEE DETAIL S106/TYP.

NOTES:
(TYP)
3/4" CHAMFER
NOTE 5
NOTE 6

DRAWINGS

INDICATED ON THE

SPACING AS

REINF SIZE AND

WALL AND SLAB
NOTE 6
NOTE 9
T.O. SLAB
NOTES 3 & 4
NOTE 2 NOTE 2
NOTE 9
SPLICE
LAP
NOTES 3 & 4
NOTES 3 & 4 NOTES 3 & 4
NOTES 3 & 4
NOTES 3 & 4 NOTE 6
T.O. SLAB
NOTE 10
NOTE 10
NOTE 10

OF WALL

SLABS AT BOTTOM
S140/TYP FOR

SEE DETAIL
NOTE 10
NOTE 7
NOTE 10
(TYP) (TYP)
NOTE 2 (TYP)
NOTE 2 (TYP)
NOTE 11
2 "
C
LR
A
-
B
-
NOTE 7
NOTES 3 & 4
(TYP
)
NOTE 5
NOTE 7
NOTES 3 & 4
NOTE 6

SECTION
NOTE 5
NOTES 3 & 4
NOTE 7
NOTE 8
NOTES 3 & 4
NOTE 7
NOTE 6
NOTE 8
2 "
C
LR
B
AR
S
AT
"S
"
4 "
4 "
(TYP
)
B
AR
S
AT
"S
"
4 "
4 "
(TYP
)
B
AR
S
AT
"S
"
4 "
4 "
(TYP
)
B
AR
S
AT
"S
"
4 "
4 "
SECTION - "W/ WSTP"

WALL HEIGHT

ELEVATIONS ALONG

INTERMEDIATE

WALLS AND AT

FOR SLABS AT TOP OF
SEE DETAIL S142/TYP
NOTE 2 NOTE 2
NOTE 9 NOTE 9
3 "
NOTE 10

DRAWINGS

INDICATED ON THE

SIZE AND SPACING AS

WALL AND SLAB REINF
NOTE 10
B
-
(TYP
)
NOTE 5
T.O. SLAB
SLAB AT 1 SIDE SLAB AT 2 SIDES
(TYP
)
B
AR
S
AT
"S
"
4 "
4 "
SECTION - "W/ WSTP"
3 "
3 "
3 "
A
-

SECTION
(TYP
)
B
AR
S
AT
"S
"
4 "
4 "
NOTE 5 T.O. SLAB
NOTE 5
SLAB AT 1 SIDE SLAB AT 2 SIDES
(TYP
)
B
AR
S
AT
"S
"
4 "
4 "

1. "S" EQUALS TYPICAL BAR SPACING INDICATED ON THE DRAWINGS.

2. 3. WATER-BLAST JOINT FACE AND PROJECTING REINFORCEMENT BEFORE PLACING CONCRETE.

4. 5.

6. 8.

BEFORE PLACING CONCRETE.

HOG RINGS MAY BE USED IN LIEU OF WIRE LOOPS. THOROUGHLY CLEAN WATERSTOP 6" PVC WATERSTOP CENTERED VERTICALLY ON JOINT. PROVIDE WIRE TIES MAX 2'-0" OC.

9. WALL. PLACE BARS AT SAME LAYERS AS IN ADJACENT SLAB OR WALL.

AT INTERSECTION, MAKE BAR SIZE THE LARGER OF BAR SIZES IN ADJACENT SLAB OR NOTES:
(SEE SPECIFICATIONS)
PLACE CEMENT GROUT OVER JOINT FACE IMMEDIATELY BEFORE PLACING CONCRETE. 1 BAR DIAMETER CLEAR.

WATERSTOP AT TOP SURFACE OF JOINT AND CENTERED BETWEEN VERTICAL BARS.

WHERE DRAWINGS INDICATE "W/ STRIP WSTP" PROVIDE LOW EXPANSION HYDROPHILIC CONSTRUCTION JOINT WHERE INDICATED ON THE DRAWINGS.

10. 7.

11. STANDARD 180° HOOK WHERE INDICATED ON THE DRAWINGS.

APPROVED BY ENGINEER.)
STANDARD 180° HOOK (ALTERNATE: 90° HOOK ROTATED OUT OF VERTICAL PLANE IF P
lotD
ate: 9-S
E
P
-2025 10:5
8:28
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:30:00-07'00'

Page 1507 of 1832 ends

"S" (TYP)
"S"/2 (TYP)
(TYP)
NOTE 6
(TYP)
NOTE 6
TYP
03/12/19
S180

CONCRETE SLABS OR WALLS

ADDITIONAL REINFORCING AT OPENINGS IN
S, N
TYP
S 04/18/17
S194

THREAD RODS

ADHESIVE BONDED REINFORCING BARS OR ALL
TYP
S 04/26/17
S184 CONCRETE CURB
12"
12" (TYP)
SEE NOTE 1
6" MIN (TYP)
TYP
S
S300 EQUIPMENT SLAB
S302
12/15/20
JOINT
3/4
"
3/4
"
3/4"
TYP
S 05/31/16
S144 WALL REINFORCEMENT AT CORNERS
0 "

LAP SPLICE
0"
0"
LAP
S
P
LIC
E
1 BAR DIA CLR
2"CLR
0"
LAP
S
P
LIC
E
0 "
LAP
TYP
S 05/31/16
S144
0"
0"
0" LAP
S
P
LIC
E
LAP
S
P
LIC
E

WALL REINFORCEMENT AT CORNERS
0 "
0 "
0 "
2 "
C
LR
TYP
N 07/21/16
S162 V-GROOVE JOINT
CE
CE
JAD
TS03
57 TYPICAL DETAILS
STRUCTURAL 3
201631-100000 201631TS03.dgn
JB
aum
barger

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G

SIDE OF OPENING (TYP)

ADD BARS ON EACH
*
*
*
IN
TER
R
U
P
TED
(TYP
)
(TYP)
"X"/2 (TYP)
"X" (TYP)

ON THE DRAWINGS

BARS AS INDICATED
B
AR
S
(TYP
)

BARS (TYP)

INTERRUPTED
C
IR
C
U
LAR
O
P
EN
IN
G
R
E
C
TAN
G
U
LAR
O
P
EN
IN
G
NOTES:

THAN 12" THICK.

EACH FACE FOR WALLS AND SLABS GREATER
AND SLABS 12" THICK OR LESS. PROVIDE 1 SET
PROVIDE 1 SET OF DIAGONAL BARS FOR WALLS
ADD 4 - #5 x 5'-0" DIAGONAL CORNER BARS.

WALL OR BEAM.

7. ADD BARS ARE NOT REQUIRED AT SIDES OF OPENINGS PARALLEL TO AND WITHIN 6" OF A OVERCUT REINFORCEMENT FOR EASIER PLACEMENT OF WEEP RINGS AND FLANGES.

6. 2" CLEAR TO CONCRETE OPENINGS OR OUTSIDE FACE OF PIPES AND PIPE SLEEVES. DO NOT LAP SPLICE LENGTH.

5. DIMENSION EQUALS OPENING DIMENSION MEASURED PERPENDICULAR TO ADD BARS PLUS

4. PLACE #5 DIAGONAL BARS ON INSIDE OF INTERRUPTED REINFORCING.

3. PLACE ADD BARS IN SAME PLANES AS INTERRUPTED REINFORCING.

CANNOT BE ACHIEVED.

2. PROVIDE STANDARD ACI HOOKS ON BARS IF STRAIGHT EXTENSION PAST THE OPENING, GREATER THAN 1/2 THE CROSS SECTIONAL AREA OF THE INTERRUPTED BARS.

1. AREA OF ADD BARS AT EACH EDGE OF OPENING IN EACH DIRECTION SHALL BE EQUAL TO OR

REINFORCING BARS

ALL-THREAD RODS
EX
IS
TIN
G
C
O
N
C
R
E
TE

NEW CONCRETE EXISTING CONCRETE
SPECIFICATIONS.

1. INSTALLATION OF REINFORCING BARS AND ALL THREAD RODS AS INDICATED IN THE NOTE:

ADHESIVE (EPOXY UNO)

ADHESIVE (EPOXY UNO)

ON THE DRAWINGS

OTHERWISE INDICATED

LAP SPLICE, UNLESS

EMBEDMENT LENGTH

SEE DRAWINGS FOR

SIZE AND SPACING

REINFORCING BAR

SEE DRAWINGS FOR

CEMENT BONDING AGENT

EPOXY RESIN/PORTLAND

AMPLITUDE AND COAT WITH
ROUGHEN CONCRETE TO 1/4"

THREAD ROD SIZE AND SPACING

SEE DRAWINGS FOR ALL

EMBEDMENT LENGTH

SEE DRAWINGS FOR

DRAWINGS
SEE
6 "
M
IN
6"

ON NEW CONCRETE

ON EXISTING CONCRETE
S
E
E
D
R
AW
IN
G
S
S
E
E
D
R
AW
IN
G
S

DRAWINGS
SEE
6 "
M
IN
2" CLR FOR FORMED SLABS.
3" CLR FOR SLABS ON GRADE.

SLABS.

FORMED
2" CLR FOR
GRADE.

SLABS ON
3" CLR FOR
NOTE 4
NOTE 2
NOTE 1
NOTE 6
NOTES 2, 3.
#3 @ 12", H2E.

NOTE 1
NOTE 6
NOTE 2
NOTE 4
NOTES 2, 5.
#3 @ 12", H1E.

NOTES 1, 3.
#3@12"
NOTES 1, 5.
#3@12"
STRIP MIN 4" BELOW TOP OF CURB.

WRAP STRIP WATERSTOP UP VERTICAL END WHERE CURB ABUTS WALL OR COLUMN. STOP HYDROPHILIC WATERSTOP AT TOP SURFACE OF JOINT AND CENTERED BETWEEN VERTICAL #3'S.

6. FOR CURB 10" & WIDER: WHERE DRAWINGS INDICATE "W/STRIP WSTP," PROVIDE LOW EXPANSION

5. SET NEW REINF IN EXISTING CONCRETE USING DETAIL S194/TYP.

EPOXY RESIN/PORTLAND CEMENT BONDING AGENT BEFORE PLACING CURB.

4. REMOVE EXISTING COATINGS. ROUGHEN CONCRETE TO 1/4" AMPLITUDE. CLEAN AND APPLY

3. HOOK PARALLEL TO CURB WHERE REQD.

ADD 1 - #4 HORIZ FOR EACH 12" HEIGHT.

2. FOR CURB WIDTH < 10". HORIZ REINF: 1 - #4 INSIDE 180° HOOK.

1. FOR CURB WIDTH > 10": HORIZ REINF: 1 - #4 EACH FACE FOR EACH 12" HEIGHT.

NOTES:

1. DIMENSIONS AS REQUIRED TO SUIT EQUIPMENT OR AS INDICATED ON THE DRAWINGS.

NOTE:
#5 (TYP)
1 MIN 6" ABC
1 1/2

LAP SPLICE
(TYP)
#5@12" EW T&B
(TYP)
TYP
WITH 12" MIN

THE DWGS

INDICATED ON

THICKNESS AS
GRADE

FINISHED

SUBGRADE

PREPARED
#5@12" (TYP)
M
IN
12 "
M
IN
4 "
& INTERSECTIONS SHEET 2 OF 2
NOTE 3
NOTE 3
NOTE 3
NOTE 2
SEE NOTE 2

BAR AT BEND
LENGTH
SPLICE

ALTERNATE

DIRECTION

OF HOOKS
SHEET 1 OF 2
HOOK

CHAMFER

CHAMFER
NOTE 2
NOTE 2
NOTE 2
NOTE 2
HOOK

3. BAR TAILS: 12 BAR DIAMETERS PLUS 12".

PLACE BARS IN SAME LAYERS AS AT CONNECTING WALLS (TYP).

2. AT INTERSECTION, MAKE BAR SIZE THE LARGER OF BAR SIZES IN CONNECTING WALLS.

DRAWINGS.

1. BAR SIZE, SPACING, AND ORIENTATION OF BAR LAYERS SHALL BE AS INDICATED ON THE NOTES:
& INTERSECTIONS
G
-
DETAIL - INTERSECTION:

CHANGE IN WALL THICKNESS
E
-
DETAIL - INTERSECTION:

DOUBLE MAT
F
-
DETAIL - INTERSECTION:

SINGLE MAT
A
-
DETAIL - CORNER:

DOUBLE MAT
B
-
DETAIL - CORNER:

SINGLE MAT
C
-

DOUBLE MAT
D
-

SINGLE MAT
DETAIL - INTERSECTION: DETAIL - INTERSECTION:

P
lotD
ate: 9-S
E
P
-2025 10:5
8:11P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:30:15-07'00'

Page 1508 of 1832 ends

TYP
SHEET 1 OF 2 06/21/19
S542
2" MIN
1/4"
NS
1/4
"

GRATING - REBATE AND SEAT

ALUMINUM TYP
S542
3 "
1/8" MAX
G
R
ATIN
G
D
E
P
TH
O
F

GRATING - REBATE AND SEAT

ALUMINUM
NS SHEET 2 OF 2 06/21/19
S350
TYP

ELECTRICAL EQUIPMENT HOUSEKEEPING PAD
A
-
B
-
S 02/21/14
TYP
N 05/20/15
S310
10 x
"D
"
1/4"
1/4"
10 x
"D
"
M
IN.
"D"

ANCHOR BOLT - EMBED AND SLEEVE
-
A
A
-
TYP
08/01/05
S510 ALUMINUM DOUBLE ANGLE BOLTED CONNECTION
3" OR 3 1/2"
B
EAM
D
E
P
TH
1 1/4" (TYP)
3 1/2" 3 1/2"
11/4
"

VERTICAL BOLT LINES

LAP SPLICE
TYP
N
S302 EQUIPMENT BASE
"D"
S310
2" CLR (TYP 4 SIDES)
12/29/2017
CE
CE
JAD
TS04
58 TYPICAL DETAILS
STRUCTURAL 4
201631-100000 201631TS04.dgn
JB
aum
barger

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
*
2"
6"
2"
*
1/8 4-12
1/8 4-12
A
-

GRATING REBATE
-

B ALTERNATE REBATE
-
B
1/4
1/4

6. = DIMENSION AS REQUIRED BY GRATING MANUFACTURER. SEE SPECIFICATIONS.

5. COAT ALUMINUM SURFACES IN CONTACT WITH CONCRETE AS SPECIFIED.

4. REBATE MAY BE EXTRUDED, SUBJECT TO ENGINEER'S ACCEPTANCE.

3. EMBEDDED REBATE ANGLE AND PLATE SHALL BE 1/4" MINIMUM THICKNESS.

2. MAKE REBATE AND/OR SEAT CONTINUOUS AROUND OPENING.

1. SEE SPECIFICATIONS FOR ALUMINUM GRATING.

NOTES:
*
1/8 4-12
1/8 4-12
N
O
TE

6. 13/4
"
-

C GRATING SEAT

AL GRATING
NOTED)
(UNLESS OTHERWISE
SST CONCRETE ANCHOR @ 2'-0".

NOTED)
(UNLESS OTHERWISE
AL L 3 x 2 x 1/4
N
O
TE
6 LOCATIONS TO FIT BETWEEN WINDOWS.

4. FOR EQUIPMENT WITH CONDUIT WINDOWS BELOW, ADJUST BAR

OVER SLAB

PAD PLACED

W/ SLAB

PAD PLACED

C ANCHOR
L
1/2" CHAMFER

C SYMM L
N
O
TE 1
N
O
TE
3 NOTE 4
(HOOKS HORIZ)
#3 @ 6"
(TYP AROUND)
#3 @ 6"
NOTE 4
#3 @ 6"
L
L
STUD ABOVE). NOTE 6.
(NEED NOT ALIGN W/ THREADED
END OF PLATE & MAX. 12" OC
ANCHOR STUD. MAX. 2" FROM
WT 2 x 6.5. NOTE 6.

6. THREADED STUD. NOTE

WELD SHOULDER)
(DIA CENTER HOLE > OD OF
THREADED STUD.
2" x 2" SHIM PACK AT EACH
JOINT

CONSTRUCTION

C ANCHOR
L

FACE OF CABINET
ROD

GALVANIZED ALL THREAD

EPOXY BONDED
C MIN 5/8"Ø x MIN 4" EMBED

2. SEE S101/ TYP FOR MIN CONCRETE COVER REQUIREMENTS.

NOTES:

STUDS.

TOUCH UP GALVANIZING AFTER FIELD WELDING THREADED

6. HOT DIP GALVANIZE WT AND HEADED ANCHOR STUD ASSEMBLY.

CABINET 4"
4"
NOTE 5
1 1/2"
4 "
PAD
11/2
"
C
LR 1"
N
O
TE
2 7
"
M
IN
S
LAB
4"
2" 2"
VERTICAL 2x FORM DURING SLAB PLACEMENT.

5. LOCATE VERTICAL EDGE OF PAD AND VERTICAL FACE OF #3s USING IS LESS THAN DIMENSION SHOWN.

3. CONTACT ENGINEER FOR INSTRUCTIONS WHERE HOOK EMBEDMENT SLAB REINFORCEMENT NOT SHOWN.

1. SEE STRUCTURAL DRAWINGS FOR THICKNESS OF SLAB BELOW PAD.

CAST-IN-ANCHOR

POST-INSTALLED ANCHOR
S
E
E
N
O
TE

3. 1/8

SST LOCK NUT
1 1/2" NON-SHRINK GROUT
1/4" SST PLATE
DETAIL
SST AB WITH 2 TO 4 THREADS EXPOSED
SEE NOTE 6.

FILL SLEEVE WITH NON-SHRINK GROUT.

ID = BOLT DIA + 2" MIN.

SST PIPE SLEEVE.
1/8" MIN WALL THICKNESS

SOLE PLATE OR SKID

EQUIPMENT BASE, BASE PLATE,

BASE PLATE, SOLE PLATE, OR SKID

ALL AROUND EQUIPMENT BASE,

COMPOUND BEAD CONTINUOUS

SYNTHETIC RUBBER SEALING
PLATE, OR SKID.

6. DO NOT USE LEVELING NUTS TO SUPPORT AND LEVEL EQUIPMENT BASE, BASE PLATE, SOLE WELD NUTS TO THE THREADED RODS.

RODS THREADED AT THE ENDS MAY BE USED IF ACCEPTABLE TO THE ENGINEER. DO NOT

5. DO NOT USE ALL THREAD RODS AS A SUBSTITUTE FOR BOLTS WITH A BOLT HEAD. SMOOTH

4. PREFABRICATED PLASTIC ANCHOR BOLT SLEEVE OPTIONAL.

PROVIDE EXTRA THICKNESS OF SLAB OR BEAM.

3. WHERE CONCRETE SLAB OR BEAM THICKNESS WILL NOT ACCOMMODATE THE ANCHOR BOLT, MANUFACTURER.

DRAWINGS, THE ANCHOR BOLT SIZE SHALL BE AS RECOMMENDED BY THE EQUIPMENT

2. ANCHOR BOLT DIAMETER AS INDICATED ON THE DRAWINGS. IF NOT INDICATED ON THE

1. "D" = DIAMETER OF ANCHOR BOLT.

NOTES:

AL COLUMN
8 AND 10 2
12 3

AL BEAM AL BEAM

AL BEAM
2 - AL L 4 x 3 1/2 x 0.250
INDICATED ON THE FRAMING PLAN BY .

1. SCHEDULE APPLIES TO ALL BEAMS UNLESS NUMBER OF BOLTS PER LEG IS OTHERWISE NOTE:

PER LEG

NUMBER OF BOLTS
(INCHES)

BEAM DEPTH
3 "
(TYP
)
(TYP
)
FOR 5 1/2" COLUMN GAGE.
2 - AL L 4 x 3 1/2 x 0.250
COLUMN GAGE OF 3 1/2" OR LESS.
2 - AL L 3 1/2 x 3 x 0.250 FOR
LARGER COLUMNS.

0.313 FOR 10" OR
2 - AL L 4 x 3 1/2 x

0.250 FOR 8" COLUMNS.
2 - AL L 3 1/2 x 3 x
FLANGES AS REQUIRED.

PLANS. COPE TOP AND BOTTOM

INDICATED ON THE FRAMING

FLUSH UNLESS OTHERWISE

TOP OF BEAMS SHALL BE

BOLTS (TYP)
3/4"Ø SST
1:1 SLOPE (TYP)

CL ANCHOR BOLT
2" CLR FOR ALL OTHER SLABS.
3" CLR FOR SLABS ON GRADE.

H
E
IG
H
T
SEE NOTE 2
AROUND
4" MIN ALL
TYP
#5 @ 12" H1E (TYP 4 SIDES)
3/4" CHAMFER
2 "
C
LR

BONDING AGENT

PORTLAND CEMENT

COAT WITH EPOXY RESIN/
1/4" AMPLITUDE AND

ROUGHEN CONCRETE TO
N
O
TE
4 (OPT)
SKID

PLATE, SOLE PLATE, OR

EQUIPMENT BASE, BASE
NOTE 6
#5 @ 12" (TYP 4 SIDES)
NOTE 5

ANCHOR BOLTS
GROUT
1 1/2" NON-SHRINK

6. PROVIDE HOOPS OR CORNERS PER DETAIL S144/TYP.

PROVIDE EXTRA THICKNESS FOR SLAB OR BEAM.

5. WHERE CONCRETE SLAB OR BEAM THICKNESS WILL NOT ACCOMMODATE THE ANCHOR BOLT,

4. HEIGHT TO SUIT EQUIPMENT FURNISHED OR AS INDICATED ON THE DRAWINGS.

MANUFACTURER'S REQUIREMENTS.

3. PAD DIMENSIONS AND ANCHOR BOLT SIZE SHALL CONFORM TO EQUIPMENT

2. THE EDGE DISTANCE ON THE ANCHOR BOLTS SHALL NOT BE LESS THAN 6" OR 8 x "D".

1. "D" = DIAMETER OF ANCHOR BOLT.

NOTES:

AND FORMS

WOOD BLOCKING

AL EXTRUSION

AL ANGLE OR

EMBEDDED
2" MAX.
1 1/4" MIN.

G
R
ATIN
G
D
E
P
TH
O
F
REMOVAL.

SMOOTH AFTER FORM

NAILS OFF AND GRIND
AL NAIL @ 2'-0" OC. CUT
PLATE
PLATE
ANGLE

LESS THAN TWO PER SIDE

MAX SPACING, AND NOT
END OF REBATE, AT 1'-6"
LOCATED 6" FROM EACH
1/2"Ø AL ROD ANCHORS
P
lotD
ate: 9-S
E
P
-2025 10:5
8:52
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:30:30-07'00'

Page 1509 of 1832 ends

S510
S542
TYP
03/16/21
S559 GRATING - FASTENERS
(ALL MATERIALS)
G
R
ATIN
G
N
O
TE
3 TYP
S550

ON THE DRAWINGS

WIDTH AS INDICATED

ALUMINUM
TH
E
D
R
AW
IN
G
S
IN
D
IC
ATED
O
N
S
PA
C
IN
G
A
S

GRATING - SUPPORT BEAMS
N SHEET 1 OF 2 06/21/19
TYP
S550
3 3/4
"
3 3/4
"
3"
1 1/2"
2 1/2"

ALUMINUM

GRATING - SUPPORT BEAMS
N SHEET 2 OF 2 06/21/19
TYP
S592 HATCH WITH LADDER
3'-6"
8"
6"
AC300
06/21/19
CE
CE
JAD
TS05
59 TYPICAL DETAILS
STRUCTURAL 5
201631-100000 201631TS05.dgn
JB
aum
barger

REV DATE BY DESCRIPTION
DATE

CHECKED
DRAWN

DESIGNED
201631
JOB NO.

DRAWING NO.

SHEET NO.

SCALES ACCORDINGLY

VERIFY SCALES

THIS SHEET, ADJUST

IF NOT ONE INCH ON

BAR IS ONE INCH ON

ORIGINAL DRAWING
0 1"
SEPTEMBER 2025 OF 59

CITY OF VALLEJO

SKYVIEW RESERVOIR REPLACEMENT PROJECT
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
1 2 3 4 5 6 7 8 9 10 11 12 13
A
B
C
D
E
F
G G
TYP
TYP

SST SADDLE CLIP
SST BOLT. MIN 2 BOLTS PER
SECTION @ ALL SUPPORTS.

SECTION OF GRATING

TOP FLANGE

OF SUPPORT
HAZARD.

3. RECESS THE GRATING CLIP WITHIN THE DEPTH OF THE GRATING TO AVOID A TRIPPING SPACING NOT TO EXCEED 8'-0".

2. GRATING FASTENERS SHALL BE INSTALLED AT EACH CORNER OF EACH PANEL AND AT

1. GRATING FASTENERS SHALL BE INSTALLED WHERE INDICATED ON THE DRAWINGS.

NOTES:

D
E
P
TH

AL GRATING

TOP OF CONCRETE
PLAN
(TYP)
(TYP
)

OF WEB AT CONNECTION TO WALL

CUT FLANGES FLUSH WITH FACE

TOP OF CONCRETE

GRATING
-
A PLAN
D
2 A
B -
2 C
2 (TYP)
~
~

REBATE (TYP)

1. COAT ALUMINUM SURFACES IN CONTACT WITH CONCRETE AS SPECIFIED.

NOTE:

CONC ANCHORS AL T 8 x 6.18
2 - AL L 4 x 3.5 x 0.375
AL RECT 1/4 x HEIGHT
GRATING x CONT
2 - AL L 4 x 3.5 x 0.375
AL T 8 x 6.18

CONC ANCHORS
1 D SECTION
1 C SECTION
1 B SECTION
~
1 1/4" (TYP)
2 - 5/8"Ø SST

REMOVABLE

KEY WRENCH

GUARDRAIL POST AS

SPRING LOADED TELESCOPING

LADDER SAFETY POST
GRAB BAR. INSTALL

WHERE INDICATED ON
THE DRAWINGS.
(TYP 2 PLACES)

ACCESS HATCH
1 1/2" TO DRAIN
TYP
P
lotD
ate: 9-S
E
P
-2025 10:59:46
P
M
U
ser:svcP
W
M
odel:Layout1 C
olorTable:gshade.ctb
D
esignS
cript:C
arollo_S
td_P
en_v0905.pen
P
lotS
cale:1:1
PROJECT NO.

LA
S
T
S
AVED
B
Y:

FILE NAME:

Digitally signed by James A. Doering
Contact Info: Carollo Engineers, Inc.

Date: 2025.09.10 14:30:46-07'00'

Page 1510 of 1832 ends