Process:

Component
Item No./Asset ID:
63 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 102959
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Pump #2 was not running. Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
N/A
Yes
Yes
Yes
No
Yes
Yes
Yes
Buena Vista Pumping Station
CHECK VALVE - SEWAGE PUMP #2, 14"
Mechanical
CKV-9902-000
2 Manufacturer Anniston AL (M&H valve co?)
Model cushioned swing, spring-loaded
1995
No
Yes
15 Yes
Yes
YesAt packing--->
No
05/13/2025 C9 544 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component
Item No./Asset ID:
64 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 103408
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Pump #4 not running Excessive vibration?
Vertically oriented Excessive noise?
Excessive Some corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
N/A
Yes
At packing--->
Yes
Yes
No
No
Yes
No
CHECK VALVE - SEWAGE PUMP #4, 14"
Buena Vista Pumping Station
Manufacturer
Model
Yes
Yes
N/A
N/A
N/A
CKV-9904-000
Mechanical
2 Anniston AL (M&H valve co?)
cushioned swing, spring-loaded
1995
15 05/13/2025 C9 545 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component
Item No./Asset ID:
66 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 104130
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive
Some leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
No
Yes
N/A
Yes
Yes
No
N/A
Yes
Yes
N/A
N/A
N/A
N/A
Manufacturer
Mechanical
2 1995
At connections-->
Model
15 N/A
N/A
V-9795-010
Buena Vista Pumping Station
PLUG VALVE - DIP FORCEMAIN W/RESTRAINT, 24"
05/13/2025 C9 546 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component
Item No./Asset ID:
67 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JW
Year Installed
Year Refurbished/Replaced Photo # 104130
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion? Yes
2 - Minor Defects Excessive leaks? Yes
3 - Requires Significant Maintenance Paint in good condition? No 4 - Requires Rehabilitation Supports in good condition? N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
No
Yes
Yes
N/A
Yes
Yes
Yes
Yes
N/A
Model
Buena Vista Pumping Station
PLUG VALVE - RESTRAINED MECH, 16"
Mechanical
5 V-9795-011
Manufacturer
1995
15 No
No
05/13/2025 C9 547 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
68 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JW
Year Installed
Year Refurbished/Replaced Photo # 103108
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion? Yes
2 - Minor Defects Excessive leaks? Yes
3 - Requires Significant Maintenance Paint in good condition? No 4 - Requires Rehabilitation Supports in good condition? N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
V-9795-012
N/A
Yes
Yes
Yes
No
Yes
Model
1995
15 No
No
Yes
Yes
N/A
Manufacturer
Buena Vista Pumping Station
PLUG VALVE - FORCE MAIN, 16"
Mechanical
5 05/13/2025 C9 548 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
69 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JW
Year Installed
Year Refurbished/Replaced Photo # 103113
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion? Yes N Yes
2 - Minor Defects Excessive leaks? Yes
3 - Requires Significant Maintenance Paint in good condition? No 4 - Requires Rehabilitation Supports in good condition? N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
No
No
Yes
Yes
N/A
5 V-9795-041
15 Yes
Yes
No
Yes
Yes
Manufacturer
Model
1995
Buena Vista Pumping Station
PLUG VALVE - FORECEMAIN, 24"
Mechanical
N/A
05/13/2025 C9 549 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
79 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JW
Year Installed
Year Refurbished/Replaced Photo # 103323
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion? Yes N Yes
2 - Minor Defects Excessive leaks? Yes
3 - Requires Significant Maintenance Paint in good condition? No 4 - Requires Rehabilitation Supports in good condition? N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
N/A
Yes
Yes
5 Yes
Manufacturer
Model
Mechanical
1995
15 No
Buena Vista Pumping Station
PLUG VALVE - 20" FORCEMAIN ISOLATION
V-9961-000
No
No
Yes
Yes
N/A
05/13/2025 C9 550 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
80 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JW
Year Installed
Year Refurbished/Replaced Photo # 103710
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion? Yes
2 - Minor Defects Excessive leaks? Yes
3 - Requires Significant Maintenance Paint in good condition? No 4 - Requires Rehabilitation Supports in good condition? N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
15 Yes
Yes
Yes
Yes
No
Manufacturer
Model
1995
Buena Vista Pumping Station
No
No
PLUG VALVE - 20" FORCEMAIN ISOLATION
Mechanical
5 V-9965-000
Yes
Yes
N/A
N/A
05/13/2025 C9 551 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
81 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JW
Year Installed
Year Refurbished/Replaced Photo # 104153
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion? Yes
2 - Minor Defects Excessive leaks? Yes
3 - Requires Significant Maintenance Paint in good condition? No 4 - Requires Rehabilitation Supports in good condition? N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
15 N/A
Yes
Yes
No
No
V-9970-000
Manufacturer
Model
Yes
Yes
Yes
Yes
N/A
No
Buena Vista Pumping Station
PLUG VALVE - 20" FORCEMAIN ISOLATION
Mechanical
5 1995
05/13/2025 C9 552 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
118
Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 113236
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
60 gal, 6 hp air supply anchorage for seismic Excessive vibration? should be checked (per Raj G) Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
PVL-9770-000
Yes
Yes
No
Yes
Yes
No
No
Yes
No
No
No
Yes
Yes
Model
1996
15 No
N/A
Buena Vista Pumping Station

TANK - HYDROPNEUMATIC TANK
Mechanical
2 Manufacturer
05/13/2025 C9 553 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
58 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 102121
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Not using external seal water system Excessive vibration? Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
Yes
Yes
N/A
No
No
Yes
N/A
Yes
No
Manufacturer
?
SWP-9901-000
N/A
N/A

4.5 Buena Vista Pumping Station
PANEL - SEAL WATER - #1 SEWAGE PUMP
Mechanical
Model
N/A
1996
15 N/A
?
Not in use-->
Yes
05/13/2025 C9 554 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
59 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 102121
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
Yes
Buena Vista Pumping Station
PANEL - SEAL WATER - #2 SEWAGE PUMP
SWP-9902-000
15 N/A
N/A
No
No
?
Yes
N/A
1996
Yes
N/A
Mechanical

4.5 Manufacturer N/A
Model N/A
Yes
No
Not in use-->
?
Yes
05/13/2025 C9 555 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
60 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 104535
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
15 N/A
Yes
N/A
No
No
1996
SWP-9904-000
?
Yes
N/A
Yes
Buena Vista Pumping Station
Manufacturer N/A
Model N/A
N/A
N/A
PANEL - SEAL WATER - #4 SEWAGE PUMP
Mechanical
5 Yes
Yes
No
?
Not in use-->
05/13/2025 C9 556 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
61 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 104535
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
15 1996
Buena Vista Pumping Station
Mechanical

4.5 Manufacturer N/A
Model N/A
?
Not in use-->
SWP-9905-000
Yes
N/A
No
No
Yes
?
Yes
N/A
PANEL - SEAL WATER - SEWAGE PUMP #5
Yes
Yes
No
N/A
N/A
N/A
05/13/2025 C9 557 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component
Item No./Asset ID:

Discipline:

Main Tab
Condition* Date of Inspection
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 112915
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Model
N/A
N/A
N/A
Buena Vista Pumping Station
Ventilation

WET WELL FAN VENTILATION STACK
Mechanical
2 Manufacturer
Yes
Yes
No
No
No
No
7/22/2015
N/A
N/A
No
?
Yes
?
05/13/2025 C9 558 of 1078
Facility:

Process:

Component
Item No./Asset ID:
65 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 103656
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Vertically oriented Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Buena Vista Pumping Station
CHECK VALVE - SEWAGE PUMP #5, 14"
Mechanical
3 CKV-9905-000
N/A
Anniston AL (M&H valve co?)
No
Yes
Yes
No
Yes
Yes
Yes
No
15 N/A
Yes
At packing-->
May be pump-->
Manufacturer
Model
cushioned swing, spring-loaded
1996
Yes
Yes
No
Yes
05/13/2025 C9 559 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component
Item No./Asset ID:
22 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 102917
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Buena Vista Pumping Station
P-9902-000
No
2008
check with electrician
Yes
Yes
No
Yes
PUMP - #2 SEWAGE
Mechanical
2 1995
No
Yes
Manufacturer Yeoman's Chicago Pump
Model 10522-6
No
20 Yes
No
No
No
Yes
No
05/13/2025 C9 560 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component
Item No./Asset ID:
163
Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 115623
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
No
Yes
No
No
MME-9750-000
No
No
N/A
Yes
Yes
N/A
Yes
Yes
N/A

DOOR - ROLL-UP (GENERATOR ROOM)
Mechanical
1 Manufacturer
Model
1995
20 Buena Vista Pumping Station
Yes
N/A
05/13/2025 C9 561 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component
Item No./Asset ID:
120
Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo # 105831
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
Yes
N/A
2001
15 SURGE TANK - FORCEMAIN
Mechanical
1 Manufacturer
Model
Buena Vista Pumping Station
PVL-9830-000
Yes
Yes
Yes
No
No
No
Yes
Yes
N/A
N/A
No
No
05/13/2025 C9 562 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
148
Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
In generator room, experiences only light use Excessive vibration? Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
Yes
?
20 Yes
N/A
Yes
C-9750-000
N/A
Model
1996
N/A
N/A
N/A
N/A
No
Yes
Yes
No
Buena Vista Pumping Station

CRANE - CHAIN HOIST (GENERATOR ROOM)
Mechanical
1 Manufacturer
05/13/2025 C9 563 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
116
Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JW
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
No
No
Buena Vista Pumping Station

GRINDER
Yes
Yes
GDR-9820-000
N/A
No
No
No
Yes
Yes
No
Mechanical
3 Manufacturer
Model
1996
2008
No
Yes
15 No
No
05/13/2025 C9 564 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
23 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Pump #4 not running Excessive vibration?
GPM= 4016/500 Head= 179/165 Excessive noise?
Excessive corrosion?
Excessive Some leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive Some corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%) ***corrosion, needs to be recoated 0 - Non-Existent
Buena Vista Pumping Station
Raw Sewage
PUMP - #4 SEWAGE
Mechanical
2 20
N/A
Manufacturer
P-9904-000
Yeoman/s Chicago Pump
Model 10522-6
1995
N/A
Intake elbow connection to pump-->
Pump #4 not running-->
N/A
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No
Yes
Some corrosion, needs to be recoated-->
2006
Intake elbow and pump base-->
N/A
05/13/2025 C9 565 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
24 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Pump #5 has more noises than other pumps. Excessive vibration? Can Hear popping in volute/impeller Excessive noise?
Could be due to hydraulics Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
***need tocheck with electrician
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
3 Manufacturer
Yeoman/s Chicago Pump
Model
1995
Yes
Yes
Mechanical
***needs more attention than other pumps
No
No
Buena Vista Pumping Station
Raw Sewage
2007
20 10522-6
Yes
Yes
?
No
No
Yes
Yes
Yes
Yes
No
No
PUMP - #5 SEWAGE
P-9905-000
05/13/2025 C9 566 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
21 Discipline:

Main Tab
Condition* Date of Inspection 7/22/2015
Assessed By JL
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Pump #1 was not running Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects **base support
3 - Requires Significant Maintenance
Excessive leaks?
4 - Requires Rehabilitation Paint in good condition?
5 - Requires Replacement (> 50%) Supports in good condition? 0 - Non-Existent
Model 10522-6
P-9901-000
Yes
Yes
N/A
N/A
Yes
not running
No
No
N/A
Yes
Mechanical
2 Manufacturer
No
1995
2008
20 Yes
No
Yes
Yes
Yeoman's Chicago Pump
Buena Vista Pumping Station
Raw sewage
PUMP - #1 SEWAGE
05/13/2025 C9 567 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
91 Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By JW
Year Installed
Year Refurbished/Replaced Photo # 112507
Nominal Useful Life (years):

Component Information Tab
Comments Structural
Spalling concrete?
Visible rebar?
Excessive corrosion to structure?
Excessive corrosion to members?
Corrosion coating intact & in place?
Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Buena Vista Pumping Station
FENCE
Structural
1 2 3 4 5 0
Manufacturer
Model
1995
20 N/A
N/A
No
N/A
No
No
No
N/A
N/A
N/A
N/A
FENCE
05/13/2025 C9 568 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
92 Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By JW
Year Installed
Year Refurbished/Replaced Photo # 123059
Nominal Useful Life (years):

Component Information Tab
Comments Structural
Significant cracking Spalling concrete?
Visible rebar?
Excessive corrosion to structure?
Excessive corrosion to members?
Corrosion coating intact & in place?
Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Structural
3 N/A
N/A
Buena Vista Pumping Station
Manufacturer
Model
1995
20 PAVEMENT - ASPHALT
N/A
N/A
N/A
N/A
N/A
Yes
N/A
N/A
N/A

PAVEMENT
05/13/2025 C9 569 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
94 Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By RG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural
Roof of wet well has multiple cracks, possibly Spalling concrete? causing the leaks inside the room. Visible rebar?
This should be fixed to prevent rebar corrosion. Excessive corrosion to structure? Excessive corrosion to members?
Corrosion coating intact & in place?
Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Structural
2 Manufacturer
Model
No
No
No
1995
50 Buena Vista Pumping Station
No
No
N/A

BUILDING - WET WELL
Yes
N/A
N/A
No
N/A

WETWELL
05/13/2025 C9 570 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
164
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By RG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural
Water leaking in causing rusting at aluminum Spalling concrete? beam and also along the perimeter wall. The Visible rebar? vault ws wet due to rain yesterday. It usually Excessive corrosion to structure? dries out bu the crew thinks it could be Excessive corrosion to members? groundwater infiltration due to the hgih water Corrosion coating intact & in place? table. It should be investigated to prevent Visible structural deformations? rebar corrosion Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent

STRUCTURE - VAULT FOR FLOW METER
Structural
3 50
Manufacturer
1995
Model
Buena Vista Pumping Station
No
No
No
Rebar: Maybe
Rebar: Maybe
Yes
No
Yes
N/A
No
N/A
STR-9790-000
05/13/2025 C9 571 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
165
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
2 Assessed By RG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural

1. 60 gal, 6 hp hydropneumatic tank air supply Spalling concrete? anchorage for seismic should be checked. Visible rebar?

2. White residue seen on ceiling of concrete roof after Excessive corrosion to structure? Most likely caused by water leak thru cracks. Excessive corrosion to members?

3. Minor shrinkage crack in basement wall. Also a Corrosion coating intact & in place? larger size crack lining up w/ C.J. in perp. wall. Visible structural deformations? Does not seem to be structural issue. Foundation settling evident?

4. The roof concrete slab leaks per David (maint). The Major cracks? expansion joint between CMU and concrete Structure Evidence of tank leakage? leaks at the floor level. The expansion joint was Joint sealant replacement? probably compromised on roof. Damaged members?

6. Random cracks in plaster on exterior wall - non-structural * Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Manufacturer
Roof concrete
1 Model
50 No
N/A
N/A

7. Expansion joint behind stair stringer on roof is broken. Water is probably leaking through this broken joint and to the floor below between the building expansion joint. 1995
N/A
No
No
No
No
BLD-9750-000

5. Roof of wet well has multiple cracks, possible causing the leaks inside the room. This should be fixed to No
No
No
Structural
Buena Vista Pumping Station

BUILDING - BUENA VISTA PUMP STATION
05/13/2025 C9 572 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By RG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural

1. Minor cracks in wood beams in a couple of locationsSpalling concrete? Sister new joists to strengthen. Visible rebar?

2. Some of wood framing appears to have been exposeExcessive corrosion to structure? to moisture but wood has not deteriorated. Excessive corrosion to members? Corrosion coating intact & in place?

3. Fans pull in moisture from the coast and probably Visible structural deformations? causing mold on a few pieces of wood. Foundation settling evident? Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
No
Manufacturer
Model
N/A
Yes
No
ROOF Generator Room
Structural
1 Buena Vista Pumping Station
No
Yes
No
N/A
No
No
05/13/2025 C9 573 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By RG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural
Spalling concrete?
Visible rebar?
Excessive corrosion to structure?
Excessive corrosion to members?
Corrosion coating intact & in place?
Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
Yes
No
No
No
N/A
N/A
No
Model
2013
No
No
Yes
Buena Vista Pumping Station

FLOW METER VAULTS, NORTH AND SOUTH
Structural

2.5 Manufacturer
05/13/2025 C9 574 of 1078
Facility / System Condition Assessment Form
Facility: Buena Vista Pumping Station
Process:

Component: SWITCH - AUTO TRANSFER SWITCH - #1 GEN
Item No./Asset ID:
125 ATS-9801-000
Discipline: Electrical and Instrumentation
Main Tab
Level of Service* 2 Date of Inspection 7/22/2015
Manufacturer Asco
Model s/o: 75276501 Assessed By SM
Year Installed 1994
Year Refurbished/Replaced Photo #
Nominal Useful Life (years): 20
Component Information Tab
Comments Electrical
Minor scratches and spots Excessive corrosion? No
Clean, well maintained contacts? Yes
Parts available for maintenance? Yes No N/A Supports in good condition? Yes No N/A Instrumentation
All critical indications functioning?Yes No N/A Alarms functional? Yes No N/A
Equipment or missing parts? Yes No N/A * Condition / Level of Service Parts available for maintenance? Yes No N/A 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
05/13/2025 C9 575 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
43 Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
No signs of corrosion or damage Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Buena Vista Pumping Station
Allen-Bradley
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A

PANEL - PUMP CONTROL
Electrical and Instrumentation
1 PCP-9800-000
Model
Manufacturer
Yes No N/A
Yes No N/A
No
1995
15 05/13/2025 C9 576 of 1078
Facility / System Condition Assessment Form
Facility: Buena Vista Pumping Station
Process:

Component: MAIN TIE BREAKER, BVPS
Item No./Asset ID:
140 MBT-9900-000
Discipline: Electrical and Instrumentation
Main Tab
Level of Service* 1 Date of Inspection 7/22/2015
Manufacturer
Model Assessed By SM
Year Installed 1995
Year Refurbished/Replaced Photo #
Nominal Useful Life (years): 20
Component Information Tab
Comments Electrical
No signs of damage or corrosion Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
05/13/2025 C9 577 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
17 Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo # 2650-2655
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
No signs of corrosion or damage Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Model
Yes
1996
2004
Yes No N/A
Yes No N/A
Buena Vista Pumping Station
Yes No N/A
Manufacturer
MOTOR - #1 SEWAGE PUMP
Electrical and Instrumentation
1 M-9901-000
Yes No N/A
10 No
Yes
Yes No N/A
05/13/2025 C9 578 of 1078
Facility / System Condition Assessment Form
Facility: Buena Vista Pumping Station
Process:

Component: PANEL - VFD, #1 SEWAGE PUMP MOTOR
Item No./Asset ID:
100 VFD-9901-000
Discipline: Electrical and Instrumentation
Main Tab
Level of Service* 5 Date of Inspection 7/22/2015
Manufacturer Allen-Bradley
Model s/o: IWC-KFKY85-V1 Assessed By SM
Year Installed 1995
Year Refurbished/Replaced 2009 Photo #
Nominal Useful Life (years): 10
Component Information Tab
Comments Electrical
No signs of corrosion or damage Excessive corrosion? Yes No N/A ***Obsolete and scheduled for replacement Clean, well maintained contacts?Yes No N/A Parts available for maintenance?Yes No N/A Supports in good condition? Yes No N/A Instrumentation
All critical indications functioning?Yes No N/A Alarms functional? Yes No N/A
Equipment or missing parts? Yes No N/A * Condition / Level of Service Parts available for maintenance?Yes No N/A 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
05/13/2025 C9 579 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
110
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
No signs of damage or corrosion Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Buena Vista Pumping Station
Manufacturer
Yes No N/A
Yes No N/A
Electrical and Instrumentation
1 2001
Yes No N/A
Yes No N/A
PNL-9830-000

CONTROL PANEL FOR SURGE TANK
Yes No N/A
Yes No N/A
15 Model
Yes No N/A
Yes No N/A
05/13/2025 C9 580 of 1078
Facility / System Condition Assessment Form
Facility: Buena Vista Pumping Station
Process:

Component: PANEL - WET WELL BUBBLWER
Item No./Asset ID:
108 PNL-9800-000
Discipline: Electrical and Instrumentation
Main Tab
Level of Service* 1 Date of Inspection 7/22/2015
Manufacturer
Model Assessed By SM
Year Installed 1995
Year Refurbished/Replaced 2005 Photo # 2662-2673
Nominal Useful Life (years): 15
Component Information Tab
Comments Electrical
No signs of corrosion. Excessive corrosion? Yes No N/A Panel in good condition Clean, well maintained contacts?Yes No N/A Parts available for maintenance?Yes No N/A Supports in good condition? Yes No N/A Instrumentation
All critical indications functioning?Yes No N/A Alarms functional? Yes No N/A
Equipment or missing parts? Yes No N/A * Condition / Level of Service Parts available for maintenance?Yes No N/A 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
05/13/2025 C9 581 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
101
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
No signs of corrosion or damage Excessive corrosion?
***Obsolete and scheduled for replacement Clean, well maintained contacts? Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
VFD-9902-000
Yes No N/A
Yes No N/A
10 Buena Vista Pumping Station
Yes No N/A
Allen-Bradley
1995
2009
Yes No N/A
Yes No N/A
5 Manufacturer
PANEL - VFD, #2 SEWAGE PUMP MOTOR
Electrical and Instrumentation
Yes No N/A
Model
Yes No N/A
Yes No N/A
s/o: IWC-HOZO93
05/13/2025 C9 582 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
142
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor scratches and spots Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
MCC-9800-B00
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Buena Vista Pumping Station
MOTOR CONTROL CENTER - #2
Electrical and Instrumentation
2 Manufacturer
Yes No N/A
Yes No N/A
Model
1995
Allen-Bradley
40 Yes No N/A
Yes No N/A
05/13/2025 C9 583 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
126
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor scratches and spots Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
SWITCH - AUTOTRANSFER SWITCH - #2 GENERATOR
Yes No N/A
20 Yes No N/A
Yes No N/A
2006
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Asco
ATS-9802-000
Manufacturer
Buena Vista Pumping Station
Electrical and Instrumentation
Model
1994
Yes No N/A
2 05/13/2025 C9 584 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
109
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor scratches Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Model

PANEL - GRINDER LEVEL
Electrical and Instrumentation
1996
15 Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
PNL-9820-000
No
Yes No N/A
Manufacturer
Buena Vista Pumping Station
2 05/13/2025 C9 585 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
146
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
No sign of corrosion or damage Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
15 Model
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
No
Yes No N/A
Yes No N/A
Electrical and Instrumentation
PNL-9815-000
1 1996

PANEL - BARSCREEN CONTROL PANEL
Buena Vista Pumping Station
Yes No N/A
Manufacturer
05/13/2025 C9 586 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
20 Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo # 2633-2637
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
No signs of damage or corrosion Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
1 Buena Vista Pumping Station
MOTOR - #5 SEWAGE PUMP
Electrical and Instrumentation
M-9905-000
Model
Manufacturer
10 No
Yes No N/A
1996
2003
05/13/2025 C9 587 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: AUTOTRANSFER SWITCH
Item No./Asset ID:
128
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor scratches and spots Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Model
ATS-9803-000
Buena Vista Pumping Station
No
20 1994
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Electrical and Instrumentation
2 AscoManufacturer
Yes No N/A
Yes No N/A
Yes No N/A
05/13/2025 C9 588 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
138
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor scratches and spots. Excessive corrosion?
Also minor signs of corrosion Clean, well maintained contacts? Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Allen-Bradley
Model
20 1995
Buena Vista Pumping Station
2 Electrical and Instrumentation
MAIN BREAKER, MCC-1
MBA-9900-000
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
No
Manufacturer
05/13/2025 C9 589 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
139
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor scratches Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Manufacturer
Model
20 Yes No N/A
MAIN BREAKER, MCC-2
Electrical and Instrumentation
MBB-9900-000
1995
Buena Vista Pumping Station
No
2 Allen-Bradley
05/13/2025 C9 590 of 1078
Facility / System Condition Assessment Form
Facility: Buena Vista Pumping Station
Process:

Component: PANEL - VFD, #4 SEWAGE PUMP MOTOR
Item No./Asset ID:
102 VFD-9904-000
Discipline: Electrical and Instrumentation
Main Tab
Level of Service* 5 Date of Inspection 7/22/2015
Manufacturer Allen-Bradley
Model s/o: IWC-KFKY85-V2 Assessed By SM
Year Installed 1995
Year Refurbished/Replaced 2009 Photo #
Nominal Useful Life (years): 10
Component Information Tab
Comments Electrical
No signs of corrosion or damage Excessive corrosion? Yes No N/A ***Obsolete and scheduled for replacement Clean, well maintained contacts?Yes No N/A Parts available for maintenance?Yes No N/A Supports in good condition? Yes No N/A Instrumentation
All critical indications functioning?Yes No N/A Alarms functional? Yes No N/A
Equipment or missing parts? Yes No N/A * Condition / Level of Service Parts available for maintenance?Yes No N/A 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
05/13/2025 C9 591 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
104
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By
Year Installed
Year Refurbished/Replaced Photo # 2762-2764 Wet well
Nominal Useful Life (years): 2765-2768 Dry well
Component Information Tab
Comments Electrical
No signs of corrosion or damage Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
1996
2008
20 Buena Vista Pumping Station
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
AE-9772-000
Electrical and Instrumentation

DETECTOR - GAS/OXYGEN ALARM UNIT, BVPS
1 Yes No N/A
Model
Manufacturer
05/13/2025 C9 592 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
18 Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo # 2656-2661
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
No signs of corrosion or damage Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
M-9902-000
1996
MOTOR - #2 SEWAGE PUMP
Electrical and Instrumentation
2007
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Manufacturer
Model
10 1
Buena Vista Pumping Station
05/13/2025 C9 593 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
127
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor scratches and spots Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
ATS-9803-00A

SWITCH - AUTOTRANSFER SWITCH
Yes No N/A
Electrical and Instrumentation
2 Buena Vista Pumping Station
20 Manufacturer Asco
1994
2006
Model
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
05/13/2025 C9 594 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
103
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
No signs of corrosion or damage Excessive corrosion?
***Obsolete and scheduled for replacement Clean, well maintained contacts? Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
PANEL - VFD, #5 SEWAGE PUMP MOTOR
VFD-9905-000
Yes No N/A
5 Model
Manufacturer Allen_Bradley
Buena Vista Pumping Station
Electrical and Instrumentation
Yes No N/A
2009
10 Yes No N/A
Yes No N/A
s/o: IWC-KFKY85-V3
1995
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
05/13/2025 C9 595 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
141
Discipline:

Main Tab
Level of Service* Date of Inspection 7/22/2015
Assessed By SM
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor signs of corrosion and scratches Excessive corrosion? Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
2 MCC-9800-A00
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
40 1995
MOTOR CONTROL CENTER - #1
Electrical and Instrumentation
Manufacturer
Model
Buena Vista Pumping Station
05/13/2025 C9 596 of 1078
PUMP STATION REHABILITATION STUDY | CITY OF VISTA
FINAL | AUGUST ͮͬͭͲ
Appendix C
RACEWAY PUMP STATION: CONDITION

ASSESSMENT FORMS
05/13/2025 C9 597 of 1078
05/13/2025 C9 598 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Condition* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 0104-0106
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Groundwater infiltration issues Excessive vibration?
Excessive noise?
esst valve to/from emergency overflow not Excessive corrosion? sealing, can see flow Excessive leaks?
Running hot?
Curbing with rail needs to be redone Capable of running when inspected? -concrete cracking at handrail posts Support equipment functional? -redo curb with appropriate insertion material Equipment or parts missing? -handrail can be reused Parts for maintenance available? Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Mechanical
4 Manufacturer
Raceway Pumping Station

STORAGE BASIN
N/A
Model
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
05/13/2025 C9 599 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
14 Discipline:

Main Tab
Condition* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 110628
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Grinder NOT INSTALLED Excessive vibration?
Not functioning Excessive noise?
Valves not exercised enough Excessive corrosion?
Valves should be separate assets Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Manufacturer
MOYNO
Model M32C3 CS7R5R
15 N/A
Raceway Pumping Station
N/A
Yes
N/A
No

CHANNEL GRINDER, RWPS
N/A
N/A
N/A
N/A
No
2006
Mechanical
5 GDR-12000-000
No
N/A
N/A
N/A
N/A
05/13/2025 C9 600 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
20 Discipline:

Main Tab
Condition* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 100551
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Well-maintained: pull up annually to inspect Excessive vibration? Ragging issues Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Model
4" D5434MV
Raceway Pumping Station
PUMP - #1 SEWAGE PUMP, SUBMERSIBLE, 75 HP, RWPS
P-12001-000
Mechanical
2 Manufacturer FAIRBANKS MORSE PUMP CO
2007
2008 operators stated more recent
15 No
Yes
Yes
No
No
No
No
Yes
**Minor on Flanges
No
N/A
N/A
No
Yes
Yes
05/13/2025 C9 601 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
21 Discipline:

Main Tab
Condition* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 100559
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Well-maintained: pull up annually to inspect Excessive vibration? Ragging issues Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Mechanical
2 Manufacturer

FAIRBANKS MORSE PUMP CO
Raceway Pumping Station
PUMP - #2 SEWAGE PUMP, SUBMERSIBLE, 75 HP, RWPS
15 Model 4" D5434MV
2007
No
No
Yes
Yes
Yes
Yes
Yes
No
No
No
P-12002-000
**Minor on Flanges
No
N/A
N/A
No
05/13/2025 C9 602 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
22 Discipline:

Main Tab
Condition* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 100541
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Well-maintained: pull up annually to inspect Excessive vibration? Ragging issues Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
2007
15 Manufacturer FAIRBANKS MORSE PUMP CO
Model 4" D5434MV
No
No
No
Yes
Yes
Yes
PUMP - #3 SEWAGE PUMP, SUBMERSIBLE, 75 HP, RWPS
Raceway Pumping Station
No
No
N/A
N/A
Yes
No
P-12003-000
Mechanical
2 **Minor on Flanges
No
Yes
05/13/2025 C9 603 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Condition* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 110708
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Exercised weekly Excessive vibration?
No sign of leakage Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Mechanical
2 Manufacturer
Raceway Pumping Station

PUMP DISCHARGE VALVES
No
Model
N/A
No
N/A
N/A
No
Yes
No
No
No
Yes
N/A
N/A
No
N/A
05/13/2025 C9 604 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: ODOR CONTROL SCRUBBER SYSTEM, LOW-FLOW, RWPS Item No./Asset ID:
19 Discipline:

Main Tab
Condition* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 101708
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Pipes brittle Excessive vibration?
Carbon has never been changed Excessive noise?
Rust on supports and bolts Excessive corrosion?

0.68 hp motor Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3- Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
No
Yes
N/A
N/A
ORF-12000-000
Mechanical
3 Manufacturer
Model FRP Radial Fume Exhauster
Raceway Pumping Station
2005
20 Yes
N/A
No
No
No
No
Yes
No
No
Yes
Yes
05/13/2025 C9 605 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
25 Discipline:

Main Tab
Condition* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 2250
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Valves get stuck, hard to move Excessive vibration?
Seals well Excessive noise?
Valves are exercised annually Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Model
N/A
N/A
N/A
N/A
N/A
N/A
Yes
Yes
Yes
No
SLG-12009-000
Hydrogate
Mechanical
2 2007
20 N/A
N/A
N/A
N/A
Manufacturer
Raceway Pumping Station
SLUICE GATE VALVE- WET WELL GRINDER SIDE, 16", RWPS
N/A
05/13/2025 C9 606 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
26 Discipline:

Main Tab
Condition* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 104
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Valves get stuck, hard to move Excessive vibration?
Seals well Excessive noise?
Valves are exercised annually Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Mechanical
2 Manufacturer
Hydrogate
Raceway Pumping Station
SLUICE GATE VALVE- WET WELL BAR RACK SIDE, 16", RWP
20 Model
2007
N/A
N/A
N/A
N/A
N/A
N/A
Yes
No
N/A
Yes
Yes
N/A
N/A
N/A
N/A
SLG-12010-000
05/13/2025 C9 607 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Condition* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 1311
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
8' chain link fencing in good condition Excessive vibration? Back fence/gate notsecure with just a lock Excessive noise? -needs a chain at least Excessive corrosion?
Roof overhangs building: easy access to site Excessive leaks? -Is fence at property line or can move it back? Running hot? Need additional security on top of fence Capable of running when inspected? -City Ord. 2003-3, Section 18.02.300.F precludes use Support equipment functional? of barbed/razor wire within city limits Equipment or parts missing? -Candy cane style security fencing acceptable Parts for maintenance available? Asphalt and concrete good Adequate for intended purpose? Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Manufacturer
Model
N/A
N/A
No
N/A
No
N/A
N/A
N/A

FENCE & PAVEMENT
Raceway Pumping Station
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Mechanical
3 05/13/2025 C9 608 of 1078
Facility / System Condition Assessment Form
Facility: Raceway Pumping Station
Process:

Component:

Item No./Asset ID:

Discipline: Mechanical
Main Tab
Condition* Date of Inspection 7/23/2015
Manufacturer
Model Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 104
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
No issues Excessive vibration? N/A
Exercised weekly Excessive noise? N/A
Excessive corrosion? No
Excessive leaks? No
Running hot? N/A
Capable of running when inspected? N/A
Support equipment functional? N/A
Equipment or parts missing? N/A
Parts for maintenance available? N/A
Adequate for intended purpose? Yes
Motor amps within rating? N/A
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
No
No
No
No

WEST FLAP GATE VALVE - WET WELL
2 05/13/2025 C9 609 of 1078
Facility / System Condition Assessment Form
Facility: Raceway Pumping Station
Process:

Component:

Item No./Asset ID:

Discipline: Mechanical
Main Tab
Condition* 4 Date of Inspection 7/23/2015
Manufacturer
Model Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 104
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Surficial, moderate corrosion and leaking reported Excessive vibration? N/A Is gasket damaged, missing? Excessive noise? N/A
Can see water flowing toward flap gate Excessive corrosion? Moderate If basin is full, will pressure of water seal the gate? Excessive leaks? Moderate Running hot? N/A
Capable of running when inspected? N/A
Support equipment functional? N/A
Equipment or parts missing? N/A
Parts for maintenance available? N/A
Adequate for intended purpose?Yes No N/A Motor amps within rating? Yes No N/A * Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
N/A
N/A
N/A

EAST FLAP GATE VALVE - WET WELL
05/13/2025 C9 610 of 1078
Facility / System Condition Assessment Form
Facility: Raceway Pumping Station
Process:

Component: WET WELL
Item No./Asset ID:

Discipline: Mechanical
Main Tab
Condition* 2 Date of Inspection 7/23/2015
Manufacturer
Model Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 100534
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Good condition Excessive vibration? N/A
Liner is good Excessive noise? N/A
Excessive corrosion? N/A
Operator concerns: Excessive leaks? No
-Mixing system to homogenize grease build up Running hot? N/A -Chopper pump? Capable of running when inspected? N/A
-spray down system? Support equipment functional? Yes
Equipment or parts missing? N/A
Parts for maintenance available? N/A
Adequate for intended purpose? Yes
Motor amps within rating? N/A
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
N/A
N/A
No
05/13/2025 C9 611 of 1078
Facility / System Condition Assessment Form
Facility: Raceway Pumping Station
Process:

Component: AIR AND VACUUM RELIEF VALVE
Item No./Asset ID:

Discipline: Mechanical
Main Tab
Condition* 2 Date of Inspection 7/23/2015
Manufacturer
Model Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Cleaned regularly, in good shape Excessive vibration? N/A Excessive noise? N/A
Excessive corrosion? No
Excessive leaks? No
Running hot? N/A
Capable of running when inspected? N/A
Support equipment functional? N/A
Equipment or parts missing? N/A
Parts for maintenance available? N/A
Adequate for intended purpose? N/A
Motor amps within rating? N/A
* Condition Piping
1 - Very Good Excessive corrosion? No
2 - Minor Defects Excessive leaks? No
3 - Requires Significant Maintenance Paint in good condition? N/A 4 - Requires Rehabilitation Supports in good condition? N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
05/13/2025 C9 612 of 1078
Facility / System Condition Assessment Form
Facility: Raceway Pumping Station
Process:

Component: BUILDING
Item No./Asset ID:

Discipline: Mechanical
Main Tab
Condition* 2 Date of Inspection 7/23/2015
Manufacturer
Model Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo # 119
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Exhaust fan- minor corrosion, looks good Excessive vibration? N/A Excessive noise? N/A
NEEDS: Excessive corrosion? No
-New solid doors to replac elouvered door that Excessive leaks? No allow plant material infiltration Running hot? N/A
-roof intake fans Capable of running when inspected? N/A Support equipment functional? N/A
Equipment or parts missing? N/A
Parts for maintenance available? N/A
Adequate for intended purpose? N/A
Motor amps within rating? N/A
* Condition Piping
1 - Very Good Excessive corrosion? No
2 - Minor Defects Excessive leaks? No
3 - Requires Significant Maintenance Paint in good condition? N/A 4 - Requires Rehabilitation Supports in good condition? N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
05/13/2025 C9 613 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 53
Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural
8' chain link fencing in good condition Spalling concrete? Back fence/gate notsecure with just a lock Visible rebar? -needs a chain at least Excessive corrosion to structure? Roof overhangs building: easy access to site Excessive corrosion to members? -Is fence at property line or can move it back? Corrosion coating intact & in place? Need additional security on top of fence Visible structural deformations? -City Ord. 2003-3, Section 18.02.300.F precludes use Foundation settling evident? of barbed/razor wire within city limits Major cracks?
-Candy cane style security fencing acceptable Evidence of tank leakage? Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Manufacturer
Model
2007
Raceway Pumping Station
3 FENCE - 8' HIGH CHAIN LINK, RWPS
Structural
FENCE
N/A
10 N/A
N/A
No
N/A
N/A
No
N/A
N/A
N/A
N/A
05/13/2025 C9 614 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 54
Discipline:

Main Tab
Level of Service* Date of Inspection
Assessed By
Year Installed
Year Refurbished/Replaced Photo # 1311
Nominal Useful Life (years):

Component Information Tab
Comments Structural
Spalling concrete?
Visible rebar?
Excessive corrosion to structure?
Excessive corrosion to members?
Corrosion coating intact & in place?
Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Raceway Pumping Station

PAVEMENT, AC - PUMP STATION SITE, RWPS

AC PAVING
Structural
2 20
2007
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Manufacturer
Model
05/13/2025 C9 615 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 3
Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/2015
Assessed By RG
Year Installed
Year Refurbished/Replaced Photo # 119
Nominal Useful Life (years):

Component Information Tab
Comments Structural

1. Overflow tank gets groundwater seeping Spalling concrete? though the bottom slab to liner joint Visible rebar?

2. PVC liner peeling in a few areas at the top of Excessive corrosion to structure? the vaults Excessive corrosion to members?

3. Roof wod exposed to outside environment; Corrosion coating intact & in place? these joists were not pressure-treated; plywood Visible structural deformations? can be seen flaking due to moisture caused Foundation settling evident? shrinkage Major cracks?

4. Joists outside the building walls are only Evidence of tank leakage? painted for protection. Can cause deterioration Joint sealant replacement? in future. Damaged members?

5. PVC liner looks in good shape in wet well, no tears or damage. * Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
No
No
No
50 No
No
Yes
No
No
No
Yes
No
Raceway Pumping Station

BUILDING
BLD-12000-000
Structural
Manufacturer
Model
1 2007
05/13/2025 C9 616 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 28
Discipline:

Main Tab
Level of Service* Date of Inspection
Assessed By JW
Year Installed
Year Refurbished/Replaced Photo # 104
Nominal Useful Life (years):

Component Information Tab
Comments Structural
groundwater leakage Spalling concrete?
Visible rebar?
Excessive corrosion to structure?
Excessive corrosion to members?
Corrosion coating intact & in place?
Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
50 2007
Manufacturer
Model
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
3 Raceway Pumping Station

EMERGENCY OVERFLOW STORAGE POND
STR-12001-000
Structural
05/13/2025 C9 617 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 29
Discipline:

Main Tab
Level of Service* Date of Inspection
Assessed By RG
Year Installed
Year Refurbished/Replaced Photo # 122-130
Nominal Useful Life (years):

Component Information Tab
Comments Structural
PVC liner looks good Spalling concrete?
No tears or damage Visible rebar?
Excessive corrosion to structure?
Excessive corrosion to members?
Corrosion coating intact & in place?
Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Raceway Pumping Station

WET WELL, RWPS
STR-12003-000
Structural
1 Manufacturer
Model
2007
50 05/13/2025 C9 618 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2781-2789
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
2 pole lights are not on the photo eye. Excessive corrosion? Fixture on top of building needs to be replaced. Clean, well maintained contacts? All other fixtures are in good condition. Parts available for maintenance? Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Manufacturer
Model
N/A
Yes
No
N/A
Yes
Raceway Pumping Station
1 N/A
N/A
N/A
Exterior Lights
Electrical and Instrumentation
05/13/2025 C9 619 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 1
Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2857-2861
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Manufacturer
GE Zenith Controls
Model
Yes
Yes
No
Yes
Yes
Yes
Electrical and Instrumentation
15 No
1 Yes
2007
Raceway Pumping Station

AUTOMATIC TRANSFER SWITCH, RWPS
ATS-12000-000
05/13/2025 C9 620 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2790-2791 &
Nominal Useful Life (years): 2849-2851
Component Information Tab
Comments Electrical
In good condition Excessive corrosion?
No reported issues Clean, well maintained contacts?
Vault has ver low risk of flooding Parts available for maintenance? Transmitter located in electrical room Supports in good condition? Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
Yes
Yes
Yes
No
Yes
Manufacturer
Sparling Tiger Mag EP
Model FM 656
No
N/A
Electrical and Instrumentation
1 Discharge Meter Vault
Raceway Pumping Station
05/13/2025 C9 621 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2852-2856
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
Yes
No
Yes
N/A
Yes
Yes
Manufacturer
Manyo Annihilator Controller
Model
Raceway Pumping Station
Grinder Control Panel
Electrical and Instrumentation
1 No
05/13/2025 C9 622 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 43
Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2801-2807
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Maintenance staff has reported issues of VFD failures Excessive corrosion? caused by dirty environment in electrical room. Clean, well maintained contacts? Minor UV degredation on FRP cable termination box. Parts available for maintenance? Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
No
Yes
Yes
Manufacturer
Allen-Bradley
Model Powerflex
2007
N/A
Yes
N/A
Yes
Raceway Pumping Station
VFD - SEWAGE PUMP # 2 RWPS
Electrical and Instrumentation
1 10
No
VFD-12002-000
05/13/2025 C9 623 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 24
Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2818-2844
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Inside of the cabinet is very dirty. Excessive corrosion? Ventilation fan I very dirty. Clean, well maintained contacts? FlexLogix PLC fails every couple months and needs Parts available for maintenance? to be reset. Supports in good condition?
FlexLogix PLC doesn no allow for redundant
processor.

Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3- Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
15 Raceway Pumping Station

PLC, RWPS
PLC-12000-000
Electrical and Instrumentation
1 Manufacturer Allen-Bradley
Model FlexLogix 5434
2007
05/13/2025 C9 624 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2792-2795
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
Yes
No
Manufacturer
Square D
Model
Electrical and Instrumentation
Raceway Pumping Station
Odor Control System
1 N/A
Yes
05/13/2025 C9 625 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2889-2893
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
8' - 2 lamp wet location flourecents in good condition Excessive corrosion? Emergency lights are functional Clean, well maintained contacts? Light switch is functional Parts available for maintenance? Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
N/A
Yes
Raceway Pumping Station
Building Interior Lights
Electrical and Instrumentation
1 Manufacturer
Model
N/A
N/A
N/A
N/A
05/13/2025 C9 626 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 44
Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2808-2813
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Maintenance staff has reported issues of VFD failures Excessive corrosion? caused by dirty environment in electrical room. Clean, well maintained contacts? Minor UV degredation on FRP cable termination box. Parts available for maintenance? Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Raceway Pumping Station
VFD - DRIVE SEWAGE PUMP#3 RWPS
Electrical and Instrumentation
2007
Powerflex
VFD-12003-000
10 No
1 Manufacturer Allen-Bradley
Model
No
N/A
Yes
N/A
Yes
Yes
Yes
05/13/2025 C9 627 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 9
Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2769-2780
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
140 of runtime Excessive corrosion?
No observed or reported issues. Clean, well maintained contacts? Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
Yes
Raceway Pumping Station
E-12000-000
Electrical and Instrumentation
20 No
Yes
1 N/A

ENGINE - EMERGENCY STANDBY GENERATOR, RWPS
Manufacturer Kohler Power Ssytems
Model 275RE0ZV
2007
No
Yes
Yes
05/13/2025 C9 628 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Level of Service* Date of Inspection 7/23/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2814-2817
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor corrosion on manifold valves. Excessive corrosion? Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Electrical and Instrumentation
1 Manufacturer
3051
Yes
Yes
No
Yes
Yes
Yes
Raceway Pumping Station
Pump Discharge manifold - Pressure transmitter gauge
Rosemount
Model
No
N/A
05/13/2025 C9 629 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 42
Discipline:

Main Tab
Level of Service* Date of Inspection
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2796-2800
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Maintenance staff has reported issues of VFD failures Excessive corrosion? caused by dirty environment in electrical room. Clean, well maintained contacts? Minor UV degredation on FRP cable termination box. Parts available for maintenance? Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
10 No
N/A
Yes
Yes
Yes
No
Yes
Manufacturer
Allen-Bradley
Model Powerflex
2007
2008
Raceway Pumping Station
VFD - SEWAGE PUMP #1 RWPS
Electrical and Instrumentation
1 N/A
7/23/15
VFD-12001-000
05/13/2025 C9 630 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID: 18
Discipline:

Main Tab
Level of Service* Date of Inspection
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2862-2888
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
MCC does not have a surge protective device. Excessive corrosion? Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
7/23/15
Yes
No
Yes
Yes
Model
CenterLine
2005
Yes
No
Yes
Yes
40 Electrical and Instrumentation
1 Manufacturer Allen-Bradley
MCC-12001-000
Raceway Pumping Station

MOTOR CONTROL CENTER, RWPS
05/13/2025 C9 631 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Ass N/A
Discipline:

Main Tab
Level of Service* Date of Inspection
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2845-2848
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
In good condition, but not functional due to high Excessive corrosion? levels of foam. Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Raceway Pumping Station
Wetwell ultrasonic level transmitter
Electrical and Instrumentation
1 Manufacturer
Siemens
No
N/A
Yes
N/A
7/23/15
Model HyroRanger 2000
Yes
Yes
Yes
No
05/13/2025 C9 632 of 1078
PUMP STATION REHABILITATION STUDY | CITY OF VISTA
FINAL | AUGUST ͮͬͭͲ
Appendix D
BUENA CREEK PUMP STATION: CONDITION

ASSESSMENT FORMS
05/13/2025 C9 633 of 1078
05/13/2025 C9 634 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks? Yes No N/A 3 - Requires Significant Maintenance Paint in good condition? Yes No N/A 4 - Requires Rehabilitation Supports in good condition? Yes No N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Model
Buena Creek Pump Station

AIR COMPRESSOR (GRINDERS HU'S)
Mechanical
2 Manufacturer
Ingersoll Rand
05/13/2025 C9 635 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical

1. Asphalt resurfacing due to large cracks Excessive vibration?

2. Berm or curb installed to direct flow to basin on Excessive noise? west side of site for containment in case of spill Excessive corrosion? coming out manholes. Prevent flow to creek Excessive leaks?

3. Fence is too short Running hot?

4. Stairs needed to access SDG&E meter on east side Capable of running when inspected? of the building; dirt hill with erosion poses a safety Support equipment functional? hazard; erosion control needed Equipment or parts missing?

5. Staging area for bypass pumping Parts for maintenance available? Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks? Yes No N/A 3 - Requires Significant Maintenance Paint in good condition? Yes No N/A 4 - Requires Rehabilitation Supports in good conditioYes No N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Model
Buena Creek Pump Station

SITE WORK
Mechanical
5 Manufacturer
05/13/2025 C9 636 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Shop# W06393 100 Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks? Yes No N/A 3 - Requires Significant Maintenance Paint in good condition? Yes No N/A 4 - Requires Rehabilitation Supports in good condition? Yes No N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Model
FRP Radial Fume Exhauster
manufactured 2004
Buena Creek Pump Station

EXHAUST FAN
Mechanical
2 Manufacturer
New York Blower Co
05/13/2025 C9 637 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Wallace 2 ton crane, 10' span Excessive vibration?
Excessive noise?
Coffey hoist Excessive corrosion?
Excessive leaks?
M522S4T10-S10 Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks? Yes No N/A 3 - Requires Significant Maintenance Paint in good condition? Yes No N/A 4 - Requires Rehabilitation Supports in good condition? Yes No N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Buena Creek Pump Station

CRANE (A-FRAME HOIST)
Mechanical
1 Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Manufacturer
Wallace Products
Model S4T10-S10
05/13/2025 C9 638 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:

Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Crew stated that reaching end of useful life and Excessive vibration? need replacement Excessive noise?
2 valves per pump used to divert flow to Shadow- Excessive corrosion? ridge and Encina Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks? Yes No N/A 3 - Requires Significant Maintenance Paint in good condition? Yes No N/A 4 - Requires Rehabilitation Supports in good condition? Yes No N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Manufacturer
Model
Buena Creek Pump Station

ELECTRIC VALVES (TO SHADOWRIDGE AND ENCINA)
Mechanical
5 05/13/2025 C9 639 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
37 P-11080-000
Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
No issues Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks? Yes No N/A 3 - Requires Significant Maintenance Paint in good condition? Yes No N/A 4 - Requires Rehabilitation Supports in good condition? Yes No N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
2 Manufacturer
Model
Buena Creek Pump Station
DRYWELL SUMP PUMP #1 BCPS
Mechanical
05/13/2025 C9 640 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
38 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
No issues Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks? Yes No N/A 3 - Requires Significant Maintenance Paint in good condition? Yes No N/A 4 - Requires Rehabilitation Supports in good condition? Yes No N/A 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
Yes No N/A
P-11090-000
Mechanical
2 Manufacturer
Model
Buena Creek Pump Station
DRYWELL SUMP PUMP #2 BCPS
05/13/2025 C9 641 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
25 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Minor corrosion on valves Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
Raceway Pumping Station

SURGE TANK - ENCINA FORCEMAIN
T-11000-000
Mechanical
2 No
Yes
Yes
Yes
Yes
No
Manufacturer
Model
2002
No
No
Yes
Yes
15 N/A
N/A
No
No
05/13/2025 C9 642 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
48 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Operators reported that forcemain valves are leaking Excessive vibration? and need replacement Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
V-11200-C01
Yes
N/A
N/A
N/A
N/A
N/A
15 5
Valmatic, Camcentric
2002
Raceway Pumping Station
PLUG VALVE - 24" FORCE MAIN
Mechanical
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
No
Manufacturer
Model
05/13/2025 C9 643 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
23 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
Yes
N/A
Yes
Yes
No
N/A
N/A
N/A
N/A
No
No
No
No
No
HU-11010-000
Mechanical
2 Manufacturer
Model
Raceway Pumping Station
HYDRAULIC UNIT CHANNEL GRINDER #1
05/13/2025 C9 644 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
24 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
No
No
Yes
N/A
N/A
N/A
N/A
No
Yes
Yes
N/A
Model
HYDRAULIC UNIT CHANNEL GRINDER #2
HU-11020-000
Mechanical
2 Manufacturer
Raceway Pumping Station
No
No
Yes
No
05/13/2025 C9 645 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
72 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
No issues noted Excessive vibration?
Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
GDR-11020-000
Yes
No
Yes
Yes
Yes
No
No
No
No
No
Yes
No
Yes
Yes
Model
Channel Monster
2002
2006
15 Raceway Pumping Station
CHANNEL GRINDER UNIT #2
Mechanical
2 Manufacturer JWC Environmental
No
05/13/2025 C9 646 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
7 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
S/N 124073 Excessive vibration?
1736 GPM Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
P-11010-000
Yes
No
Yes
Yes
No
Yes
Yes
PUMP - #1, SEWAGE
Mechanical
2 No
No
No
No
Manufacturer
Cornell Pumps
Model 8NNT
2002
20 Raceway Pumping Station
No
No
Yes
Yes
05/13/2025 C9 647 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
82 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
Condition level 3 due to housing Excessive vibration?
Minor corrosion on baseFiberglass with surficial cracks Excessive noise? Fiberglass needs to be patched and painted Excessive corrosion? Fans, solenoids, and piping good Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
2002
N/A
No
Yes
Yes
No
Yes
Yes
N/A
Yes
No
N/A
20 Raceway Pumping Station

ODOR CONTROL UNIT -BIO-FILTER
ORF-11000-000
Mechanical
3 N/A
N/A
No
No
Manufacturer
Model
05/13/2025 C9 648 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
71 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
No issues noted Excessive vibration?
A spare unit is kept onsite Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
GDR-11010-000
Yes
Yes
No
No
Yes
Yes
No
Yes
No
No
Yes
Yes
2008
15 No
No
No
2 Manufacturer
JWC Environmental
Model Channel Monster
2002
Raceway Pumping Station
CHANNEL GRINDER UNIT #1
Mechanical
05/13/2025 C9 649 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
8 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
S/N 124072 Excessive vibration?
3600GPM Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
P-11020-000
Yes
Yes
Yes
No
No
No
Yes
Yes
No
2002
2007
20 No
No
Mechanical
2 Manufacturer Cornell Pumps
Model 8NNT
Raceway Pumping Station
PUMP - #2, SEWAGE
No
No
Yes
Yes
05/13/2025 C9 650 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
9 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
S/N 124071 Excessive vibration?
2037 GPM Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion? Yes N
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
Yes
No
No
Yes
Model
8NNT
2002
2008
20 Raceway Pumping Station
PUMP - #3, SEWAGE
P-11030-000
Mechanical
2 Manufacturer Cornell Pumps
No
No
No
No
No
Yes
Yes
05/13/2025 C9 651 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
10 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
S/N 124070 Excessive vibration?
2037 GPM Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
P-11040-000
Yes
No
Yes
Yes
Yes
No
No
No
No
No
Yes
Model
8NNT
2002
2008
20 Raceway Pumping Station
PUMP - #4, SEWAGE
Mechanical
2 Manufacturer Cornell Pumps
No
No
Yes
Yes
05/13/2025 C9 652 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
11 Discipline:

Main Tab
Condition* Date of Inspection 7/28/2015
Assessed By JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Mechanical
S/N 124069 Excessive vibration?
2037 GPM Excessive noise?
Excessive corrosion?
Excessive leaks?
Running hot?
Capable of running when inspected?
Support equipment functional?
Equipment or parts missing?
Parts for maintenance available?
Adequate for intended purpose?
Motor amps within rating?
* Condition Piping
1 - Very Good Excessive corrosion?
2 - Minor Defects Excessive leaks?
3 - Requires Significant Maintenance Paint in good condition? 4 - Requires Rehabilitation Supports in good condition? 5 - Requires Replacement (> 50%)
0 - Non-Existent
P-11050-000
Yes
No
Yes
Yes
No
Yes
Yes
PUMP - #5, SEWAGE
Mechanical
2 No
No
No
No
Manufacturer
Cornell Pumps
Model 8NNT
2002
2008
20 Raceway Pumping Station
No
No
Yes
Yes
05/13/2025 C9 653 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
83 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Manufacturer
Model Assessed By RG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural

1. Water leaking from west wall penetraion close to Spalling concrete? mechanical duct; groundwater can be seen dripping' Visible rebar?

2. Evidence of past leak at bottom of wet well (12" Excessive corrosion to structure? wall at north); evidence of water leak at bottom Excessive corrosion to members? of east wall as well Corrosion coating intact & in place?

3. Evidence of past leak and calcium seen on south Visible structural deformations? wall near stair entrance. Seems like it was patched Foundation settling evident? before with plaster concrete Major cracks?

4. Evidence of leak at bottom of south wall Evidence of tank leakage?

5. Crack in overhead slab at south-west corner Joint sealant replacement?

6. Small hairline cracks on walls, appear to be minor Damaged members? non-structural cracks.

7. Patch on south wall was done during first year of
construction due to leak issues. Since then it does
seem like leak occurred at crack in the past.

8. Seal the leak on west wall to stop water infiltration into the room. * Condition / Level of Service
1-Very Good
2-Minor Defects
3-Requires Significant Maintenance
4-Requires Rehabilitation
5-Requires Replacement (> 50%)
0-Non-Existent
No
No
No
Yes
Yes
No
No
No
Yes
No
No
Buena Creek Pump Station
Structural
2 2002
50 BUILDING - BUENA CREEK PUMP STATION
BLD-11000-000
05/13/2025 C9 654 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
84 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Manufacturer
Model Assessed By JW
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural
PVC liner known to be failing; will be replaced in Spalling concrete? an upcoming project. Visible rebar?
Concrete not visible Excessive corrosion to structure?
Grinders look ok Excessive corrosion to members?
Stainless gates look ok Corrosion coating intact & in place? Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1-Very Good
2-Minor Defects
3-Requires Significant Maintenance
4-Requires Rehabilitation
5-Requires Replacement (> 50%)
0-Non-Existent

BUILDING - WET WELL

WET WELL
N/A
N/A
N/A
N/A
N/A
N/A
N/A
50 N/A
N/A
N/A
N/A
Structural
4 2002
Buena Creek Pump Station
05/13/2025 C9 655 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
54 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Manufacturer
Model Assessed By JW
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural
Abandoned Shadkowridge pump vault used for Spalling concrete? emergency storage; 50K gal capacity Visible rebar?
Unlined vault Excessive corrosion to structure?
Small sump for pump back to wet well Excessive corrosion to members? No major issues Corrosion coating intact & in place?
Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1-Very Good
2-Minor Defects
3-Requires Significant Maintenance
4-Requires Rehabilitation
5-Requires Replacement (> 50%)
0-Non-Existent
No
No
No
No
No
Buena Creek Pump Station
Structural
2 No
N/A
No
2002
50 No
No
No

BASIN - OVERFLOW
BASIN
05/13/2025 C9 656 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
53 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Manufacturer
Model Assessed By RG & JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural
JW/RLG: fence too short Spalling concrete?
Visible rebar?
Excessive corrosion to structure?
Excessive corrosion to members?
Corrosion coating intact & in place?
Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1-Very Good
2-Minor Defects
3-Requires Significant Maintenance
4-Requires Rehabilitation
5-Requires Replacement (> 50%)
0-Non-Existent
N/A
N/A
No
No
No
RG-1; JW/RLG-4
Yes
No
No
No
2002
20 No
N/A
Buena Creek Pump Station
Structural
FENCE - 8' HIGH CHAIN LINK
FENCE
05/13/2025 C9 657 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
52 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Manufacturer
Model Assessed By RG & JW/RLG
Year Installed
Year Refurbished/Replaced Photo #
Nominal Useful Life (years):

Component Information Tab
Comments Structural
RG: Pavement has relatively large cracks on surface Spalling concrete? Visible rebar?
JW/RLG: Asphalt needs resurfacing due to extensive Excessive corrosion to structure? cracking Excessive corrosion to members?
Corrosion coating intact & in place?
Visible structural deformations?
Foundation settling evident?
Major cracks?
Evidence of tank leakage?
Joint sealant replacement?
Damaged members?
* Condition / Level of Service
1-Very Good
2-Minor Defects
3-Requires Significant Maintenance
4-Requires Rehabilitation
5-Requires Replacement (> 50%)
0-Non-Existent
N/A
N/A
N/A
No
Yes
N/A
N/A
N/A
N/A
N/A
N/A
2002
20 Buena Creek Pump Station
Structural
RG-2; JW/RLG-5

PAVEMENT - AC
19 05/13/2025 C9 658 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
2 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3003-3022
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor corrosion on suction side diaphram seal. Excessive corrosion? Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
M-11010-000
No
Yes
Yes
Yes
Yes
Yes
Buena Creek Pump Station
MOTOR - #1 SEWAGE PUMP
Electrical and Instrumentation
1 10
No
Yes
Manufacturer Licoln Motors
Model
2002
05/13/2025 C9 659 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
3 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3023-3045
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor corrosion on suction side diaphram seal. Excessive corrosion? Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
M-11020-000
MOTOR - #2 SEWAGE PUMP
Yes
Yes
Yes
No
Yes
Yes
No
Yes
2002
10 Manufacturer Licoln Motors
Model
1 Buena Creek Pump Station
Electrical and Instrumentation
05/13/2025 C9 660 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
4 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3046-3067
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor corrosion on suction side diaphram seal. Excessive corrosion? Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
MOTOR - #3 SEWAGE PUMP
Yes
No
Yes
Yes
Yes
No
Yes
Yes
10 Model
2002
1 Manufacturer Licoln Motors
Buena Creek Pump Station
Electrical and Instrumentation
M-11030-000
05/13/2025 C9 661 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
5 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3068-3089
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor corrosion on suction side diaphram seal. Excessive corrosion? Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
Yes
No
Yes
No
Yes
Yes
Yes
10 Model
2002
1 Manufacturer Licoln Motors
Buena Creek Pump Station
Electrical and Instrumentation
MOTOR - #4 SEWAGE PUMP
M-11040-000
05/13/2025 C9 662 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
6 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3090-3109
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor corrosion on suction side diaphram seal. Excessive corrosion? Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
Yes
No
Yes
Yes
10 Model
2002
1 Manufacturer Licoln Motors
Buena Creek Pump Station
Electrical and Instrumentation
MOTOR - #5 SEWAGE PUMP
M-11050-000
05/13/2025 C9 663 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
16 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 313-3121
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
Yes
Yes
No
Yes
No
N/A
Yes
10 Model
2002
1 Manufacturer
Buena Creek Pump Station
Electrical and Instrumentation
FLOW METER - ENCINA FORCEMAIN 14"
FE-11020-000
05/13/2025 C9 664 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
66 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2977-2980
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
VFD's are obsolete and will be replaced as part Excessive corrosion? of current project. Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
VFD - #2, SEWAGE PUMP BCPS
VFD-11020-000
Yes
Yes
Yes
No
Model
2002
10 No
N/A
Yes
Yes
Buena Creek Pump Station
Electrical and Instrumentation
5 Manufacturer
Allen-Bradley
05/13/2025 C9 665 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
67 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2973-2976
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
VFD's are obsolete and will be replaced as part Excessive corrosion? of current project. Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
VFD - #3, SEWAGE PUMP BCPS
VFD-11030-000
Yes
Yes
Yes
No
Yes
Yes
No
N/A
2002
10 Manufacturer Allen-Bradley
Model
5 Buena Creek Pump Station
Electrical and Instrumentation
05/13/2025 C9 666 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
68 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2970-2972
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
VFD's are obsolete and will be replaced as part Excessive corrosion? of current project. Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
VFD - #4, SEWAGE PUMP BCPS
Yes
No
Yes
Yes
Yes
No
N/A
Yes
10 Model
2002
5 Manufacturer Allen-Bradley
Buena Creek Pump Station
Electrical and Instrumentation
VFD-11040-000
05/13/2025 C9 667 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
69 VFD-11050-
000
Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2965-2969
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
VFD's are obsolete and will be replaced as part Excessive corrosion? of current project. Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
Yes
No
Yes
No
Yes
N/A
Yes
10 Model
2002
5 Manufacturer Allen-Bradley
Buena Creek Pump Station
Electrical and Instrumentation
VFD - #5, SEWAGE PUMP BCPS
05/13/2025 C9 668 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
14 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3126-3131
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
This 1 panel used for both dry well and wetwell. Excessive corrosion? Using a manual 3-way valve to switch between Clean, well maintained contacts? wetwell and dry well air samples. Parts available for maintenance? Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
N/A
No
N/A
Yes
2006
10 Model
2002
1 Manufacturer MSA
Buena Creek Pump Station
Electrical and Instrumentation

GAS ANALYZER DRY WELL
AE-11010-000
05/13/2025 C9 669 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
70 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3145-3176
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
PLC to be replaced. Excessive corrosion?
Client wants hard-wired data link type connection Clean, well maintained contacts? between PLC and flow meter. Parts available for maintenance? Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
Yes
Yes
No
Yes
No
Yes
Yes
15 Model
5/40C
2002
4 Manufacturer Allen-Bradley
Buena Creek Pump Station
Electrical and Instrumentation

CONTROL PANEL - PLC (BCPS)
PNL-11000-000
05/13/2025 C9 670 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
77 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2900-2916
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Minor corrosion on exhaust silencers. Excessive corrosion? Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
G-11000-000
EMERGENCY STANDBY GENERATOR / 500 KW
Yes
Yes
Yes
No
Yes
Yes
No
Yes
2002
20 Manufacturer Kohler Power Systems
Model
Buena Creek Pump Station
Electrical and Instrumentation
1 05/13/2025 C9 671 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
1 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2945-3002
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
VFD's are obsolete and will be replaced as part Excessive corrosion? of current project. Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
MCC-11000-000

MOTOR CONTROL PANEL
Yes
No
Yes
Yes
Yes
No
N/A
Yes
40 Model Centerline
2002
Electrical and Instrumentation
1 Manufacturer Allen-Bradley
Buena Creek Pump Station
05/13/2025 C9 672 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: Exterior Lighting
Item No./Asset ID: N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2927-2933
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
The lights on the west side of the building will be Excessive corrosion? replaced by Encina maintenance. Clean, well maintained contacts? Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
N/A
N/A
N/A
Yes
No
N/A
Yes
Model
1 Manufacturer
Buena Creek Pump Station
Electrical and Instrumentation
05/13/2025 C9 673 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: Force Main Flow Meter (ShadowRidge)
Item No./Asset ID: N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3122-3125
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
Yes
No
N/A
Yes
Model
1 Manufacturer
Buena Creek Pump Station
Electrical and Instrumentation
05/13/2025 C9 674 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: Grinders
Item No./Asset ID: N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3138-3144
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
N/A
No
N/A
Yes
Model
1 Manufacturer
Buena Creek Pump Station
Electrical and Instrumentation
05/13/2025 C9 675 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: Return Pump
Item No./Asset ID: N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/15
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3177-3180
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Replace pilot lights. Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
No
Model
Buena Creek Pump Station
Yes
Yes
Yes
No
Yes
Electrical and Instrumentation
1 Manufacturer
N/A
Yes
05/13/2025 C9 676 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
65 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2981-2984
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
VFD's are obsolete and will be replaced as part Excessive corrosion? of current project. Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
Yes
No
N/A
Yes
10 Model
2002
5 Manufacturer Allen-Bradley
Buena Creek Pump Station
Electrical and Instrumentation
VFD - #1, SEWAGE PUMP BCPS
VFD-11010-000
05/13/2025 C9 677 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component:

Item No./Asset ID:
64 Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2945-2947
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
Yes
No
N/A
Yes
2007
15 Model MX 200
2002
1 Manufacturer Allen-Bradley
Buena Creek Pump Station
Electrical and Instrumentation

AUTOMATIC TRANSFER SWITCH
ATS-11000-000
05/13/2025 C9 678 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: Service Entrance
Item No./Asset ID: N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2894-2899
Nominal Useful Life (years): 2917-2926
Component Information Tab
Comments Electrical
Very minor corrosion on exterior of enclosure. Excessive corrosion? Challenging access, recommend installing Clean, well maintained contacts? staircase. Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
N/A
N/A
N/A
Yes
Yes
No
N/A
Manufacturer
GE
Model
Buena Creek Pump Station
Electrical and Instrumentation
1 05/13/2025 C9 679 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: Interior Lighting
Item No./Asset ID: N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 2934-2944
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
No reported or observed issues. Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
N/A
N/A
N/A
N/A
Yes
No
N/A
Yes
Model
Electrical and Instrumentation
1 Manufacturer
Buena Creek Pump Station
05/13/2025 C9 680 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: Blower Motor High Water Floats
Item No./Asset ID: N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3110-3112
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
N/A
No
N/A
Yes
Model
1 Manufacturer
Buena Creek Pump Station
Electrical and Instrumentation
05/13/2025 C9 681 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: Air Compressor
Item No./Asset ID: N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3132-3137
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
N/A
No
N/A
Yes
Model
1 Manufacturer
Buena Creek Pump Station
Electrical and Instrumentation
05/13/2025 C9 682 of 1078
Facility / System Condition Assessment Form
Facility:

Process:

Component: Odor Control Blower Control Panel
Item No./Asset ID: N/A
Discipline:

Main Tab
Level of Service* Date of Inspection 7/28/2015
Assessed By TH/AM
Year Installed
Year Refurbished/Replaced Photo # 3181-3184
Nominal Useful Life (years):

Component Information Tab
Comments Electrical
Replace pilot lights. Excessive corrosion?
Clean, well maintained contacts?
Parts available for maintenance?
Supports in good condition?
Instrumentation
All critical indications functioning?
Alarms functional?
Equipment or missing parts?
* Condition / Level of Service Parts available for maintenance? 1 - Very Good
2 - Minor Defects
3 - Requires Significant Maintenance
4 - Requires Rehabilitation
5 - Requires Replacement (> 50%)
0 - Non-Existent
Yes
No
Yes
Yes
Yes
No
N/A
Yes
Model
1 Manufacturer
Buena Creek Pump Station
Electrical and Instrumentation
05/13/2025 C9 683 of 1078
05/13/2025 C9 684 of 1078
PUMP STATION REHABILITATION STUDY | CITY OF VISTA
FINAL | AUGUST ͮͬͭͲ
Appendix E

V&A CONSUL TING ENGINEERS PUMP STATION

CONDITION ASSESSMENTS DRAFT REPORT
05/13/2025 C9 685 of 1078
05/13/2025 C9 686 of 1078

CITY OF VISTA, CALIFORNIA

PUMP STATION CONDITION ASSESSMENTS

DRAFT REPORT

Prepared for: Carollo Engineers, Inc.
5075 Shoreham Place
Suite 120
San Diego, CA 92122
Date: March 2016
Prepared by:

V&A Project No. 15-0024

05/13/2025 C9 687 of 1078
05/13/2025 C9 688 of 1078
V&A Project No. 15-0024 Table of Contents i

TABLE OF CONTENTS
ES EXECUTIVE SUMMARY............................................................................................................ .......... 1 Actions carried out on September 9, 10, and 11, 2015: .................................................................. 1 Actions carried out on January 12, 2016: .......................................................................................... 1

1.0 INTRODUCTION ............................................................................................................... .................. 6

2.0 ASSESSMENT APPROACH ........................................................................................................ ........ 8

2.1 Access ..................................................................................................................... .......................... 8

2.2 Visual Assessment .......................................................................................................... ................. 8

2.3 Ultrasonic Thickness Testing ........................................................................................................... 9

2.3.1 Wall Thickness Loss Analysis ............................................................................................. .... 9

2.4 Pit Depth Measurements .............................................................................................................. 10

2.5 Vibration Analysis ......................................................................................................... ................. 10

2.6 In-Situ Soil Resistivity .................................................................................................................... 11

2.6.1 Wenner Four-Electrode Method: General Information ...................................................... 11

2.6.2 Soil Resistivity Calculation – to Depth ................................................................................ 12

2.6.3 Soil Resistivity Calculation – per Layer (Barnes Method) ................................................. 13

2.7 Soil Sample Analysis ....................................................................................................... .............. 14

2.7.1 Resistivity .............................................................................................................. ............... 14

2.7.2 Bicarbonate Ions ......................................................................................................... ......... 14

2.7.3 Chloride Ions ............................................................................................................ ............ 15

2.7.4 Sulfate Ions ............................................................................................................. ............. 15

2.7.5 Soil pH .................................................................................................................. ................ 15

2.8 VANDA ® Metal Condition Index..................................................................................................... 16

2.9 VANDA ® Concrete Condition Index ............................................................................................... 17

3.0 BUENA CREEK PUMP STATION AND PIPELINES .......................................................................... 18

3.1 Dry Well Visual Assessment .......................................................................................................... 18

3.2 Ultrasonic Thickness Measurements ........................................................................................... 22

3.3 Vibration Analysis Results ............................................................................................................. 23

3.4 In-situ Soil Resistivity Results ....................................................................................................... 23

3.5 Soil Sample Analysis Results ........................................................................................................ 25

3.6 Conclusions ................................................................................................................ ................... 26

3.7 Recommendations ............................................................................................................ ............ 27

4.0 BUENA VISTA PUMP STATION ................................................................................................... .... 28 05/13/2025 C9 689 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Table of Contents ii

4.1 Dry Well Visual Assessment .......................................................................................................... 28

4.2 Meter Vault Visual Assessments .................................................................................................. 32

4.3 Ultrasonic Thickness Measurements ........................................................................................... 35

4.4 Vibration Analysis Results ............................................................................................................. 36

4.5 Conclusions ................................................................................................................ ................... 37

4.6 Recommendations ............................................................................................................ ............ 38

5.0 RACEWAY PUMP STATION ....................................................................................................... ...... 40

5.1 Visual Assessment .......................................................................................................... .............. 40

5.2 Ultrasonic Thickness Measurements ........................................................................................... 41

5.3 Conclusions ................................................................................................................ ................... 42

5.4 Recommendations ............................................................................................................ ............ 43 APPENDIX A. REED ELECTRIC & FIELD SERVICES VIBRATION ANALYSIS REPORT .................................. 1 APPENDIX B. IN-SITU SOIL RESISTIVITY COMPLETE RESULTS .................................................................. 1 APPENDIX C. PROJECT X CORROSION ENGINEERING SOIL ANALYSIS REPORT ...................................... 1 TABLES
Table ES-1. Buena Creek Pump Station Assessment Summary ............................................................... 2 Table ES-2. Buena Vista Pump Station Assessment Summary ................................................................ 3 Table ES-3. Raceway Pump Station Assessment Summary ...................................................................... 5 Table 2-1. Effect of Resistivity on Soil Corrosivity ................................................................................... 14 Table 2-2. Effect of Chloride Ions on Soil Corrosivity .............................................................................. 15 Table 2-3. Effect of Sulfate Ions on Soil Corrosivity ................................................................................ 15 Table 2-4. Effect of pH on Soil Corrosivity ............................................................................................... 16 Table 2-5. VANDA
® Metal Condition Index .............................................................................................. 16 Table 2-6. VANDA® Concrete Condition Index ......................................................................................... 17 Table 3-1. Buena Creek Pump Station Ultrasonic Thickness Data Summary ....................................... 22 Table 3-2. Buena Creek Pump Station Vibration Analysis Results ........................................................ 23 Table 3-3. Summary of In-Situ Soil Resistivity Test Results ................................................................... 24 Table 3-4. Summary of Laboratory Soil Analysis Results ....................................................................... 26 Table 4-1. Buena Vista Pump Station Ultrasonic Thickness Data Summary ........................................ 36 Table 4-2. Buena Vista Pump Station Vibration Analysis Summary ...................................................... 37 Table 5-1. Raceway Pump Station Ultrasonic Thickness Data Summary ............................................. 42 05/13/2025 C9 690 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Table of Contents iii

FIGURES
Figure 1—1. Aerial Map Showing Locations of the Buena Creek, Buena Vista, and Raceway Pump Stations ...................................................................................................................................... 6 Figure 2—1. Standard Pit Depth Gage ..................................................................................................... 10 Figure 2—2. Typical Reed Electric Vibration Test Monitoring Sites on Pump Motors ........................... 11 Figure 2—3. Wenner 4-Electrode Method Schematic ............................................................................. 12 Figure 3—1. Soil Resistivity Testing Site Plan .......................................................................................... 24 Figure 3—2 Excavation Location Site Plan .............................................................................................. 25

05/13/2025 C9 691 of 1078
05/13/2025 C9 692 of 1078
V&A Project No. 15-0024 1

ES EXECUTIVE SUMMARY
V&A Consulting Engineers, Inc. (V&A) was retained by Carollo Engineers, Inc. (Carollo) to conduct a condition assessment of the Buena Vista Pump Station (BVPS), the Buena Creek Pump Station (BCPS), and the Raceway Pump Station (RPS). Thes e stations are owned by the City of Vista and Buena Sanitation District, and operated by the Encina Wastewater Authority. The intent of the assessments are to assist in preparing Preliminary Design Reports for the three pump stations which will outline capital projects and plan budgets for future fiscal years. Concrete surfaces, piping, motors, and pumps were evaluated in each of the three pump stations. The assessment methods used to assess these features are as follows:

Actions carried out on September 9, 10, and 11, 2015:
x Visual evaluation of the concrete surfaces an d metal piping and appurtenances in the BCPS and BVPS dry wells using digital photographs to document notable observations. x Visual evaluation of coatings on concrete and metal structures x Pit depth measurement on corroded metallic surf aces in the BCPS and BVPS dry wells and on above grade RPS piping.
x Pipe wall thickness measurements using an ultrasonic testing gage for dry well piping in the BCPS and BVPS dry wells, and on above grade piping at the RPS. x Rating the evaluated concrete and metal surfaces using the VANDA ® Concrete and Metal Condition Index
x Motor and pump vibration analysis by Reed Electric at BCPS and BVPS Actions carried out on January 12, 2016:
x In-situ soil resistivity testin g along the 16-inch diameter force main and 14-inch diameter excess effluent pipeline alignments for the BC PS. Cursory foreign utility investigation along both ductile iron pipelines (DIPs) for potent ial cathodically protected structures. After potholing over the pipeline, collected three soil samples at pipe depth for corrosivity analysis.

Soil samples were laboratory tested for as-rec eived and saturated (minimum) soil resistivity, pH, and soluble chloride, sulfate, and bicarbonate ion concentrations. 05/13/2025 C9 693 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Executive Summary 2

Conclusions and recommendations based on the results of the assessments are presented in Table ES-1 through Table ES-3:

Table ES-1. Buena Creek Pump Station Assessment Summary CConclusion Recommendation Implementation
Timeframe (years)
The evaluated concrete surfaces are in
good condition. However, there was
evidence of infiltration at the pipe
penetrations and on the south wall of the
dry well.

The evidence of groundwater infiltration on
the concrete walls and the corrosive soil
environment the pump station is located in
warrant additional testing in the concrete
pump room.
0 to 2
Metal surfaces are in good condition with
the majority of the coating (about 90% )
intact. There is some copper piping t hat is
significantly corroded.

Repair damaged coating on mechanical
equipment and piping as needed. Clean
the surfaces of the copper piping and
determine if the replacement of copper
piping is warranted.
3 to 5
At most of the testing locations, the
ductile iron pipe is in good condition.

There were a few locations that showed
wall thickness outside the manufacturing
tolerances by what is considered a minor
degree. No significant exterior corrosion
or leaks were observed on the rest of the
piping in the dry well, which was outside
the ultrasonic testing areas.

Routine assessment.
5 to 10
The inverted pendulum arrangement of
the motor and pumps appears to be a
significant issue with respe ct to seismic
loading.

Evaluate the seismic vulnerability of the
motor and pump arrangement. 0 to 2
Vibration levels are high on most motor
and pump test locations, with many
exceeding ISO and Hydraulic Institute
acceptance standards for operating
levels.

Reed Electric recommended additional
testing during the next planned outage.
0 to 2
The buried excess effluent and force main
ductile iron pipes are within a moderately
to very highly corrosive soil environment.

Consider cathodic protection for buried
metal piping if it is to remain in service for
the next 20 years. If a new pipeline is to be
installed, alternative materials to metal or
concrete, such as plastic, should be
considered.

As Appropriate

05/13/2025 C9 694 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Executive Summary 3

Table ES-2. Buena Vista Pump Station Assessment Summary CConclusion Recommendation Implementation
Timeframe (years)
In general, the concrete interior surfaces
of the dry well were in good condition.

There were, however, some isolated areas
of groundwater infiltration, some with
staining indicating possible corrosion of
the reinforcing steel. The grout pads
under the pump b ases showed
deterioration at the edges in some cases.

Monitor areas of infilt ration within the dry
well for increased evidence of infiltration or
corrosion staining. Consider further
evaluation of the concrete and reinforcing
steel in areas where there is corrosion
staining.
0 to 2
The coating on the piping was generally in
good condition at higher elevations, with
numerous chips and other defects in the
coating at lower elevations. Generally,
there was minor surface corrosion where
the coating was damaged. There was also
one spool downstream of Pumps 1 and 2
that exhibited moderate external
corrosion.

Repair damaged coating on mechanical
equipment and piping as needed.
0 to 2
At most of the ultrasonic thickness testing
locations, the dry well pipin g is in good
condition, but there was one location on
the header downstream of Pumps 1 and 2
that exhibited a significant thickness loss
of 37%. This location also exhibited
external corrosion. It is possible, though
considered unlikely, that the pipe at t his
location was manufactured thinner than
required by AWWA standards. No
significant exterior corrosion or leaks were
observed on the rest of the piping in the
dry well, which was outside the ultrasonic
testing areas.

Calculate the minimum required thickn ess
for the piping based on pressure, loading,
etc. Compare the minimum required
thickness against the measured
thicknesses in this report to determine the
amount of further wall loss that can be
tolerated, if any, before the integrity of the
piping is imp aired. With the results of this
analysis in mind, consider activities to
address corrosion and int egrity of the dry
well piping:
3 to 5
The bathroom drain piping and ventilation
ducting exhibited various moderate -
severity defects.

Repair the bathroom drain piping and
ventilation ducting connections. 0 to 2
The meter vaults show moderate to
extensive groundwater infiltration, with
staining that indicates possible corrosion
of the reinforcing steel. The vaults are
only a few years old. The extent of staining
may indicate that the water leaking into
the vaults is brackish, which would
promote corrosion.

Perform testing to quantify the extent of
degradation of the concrete and
reinforcement in the two meter vaults.

Testing to consider is similar to that
recommended for the dry well. Sample the
water entering the vaults for resistivity and
chloride content.
0 to 2
05/13/2025 C9 695 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Executive Summary 4

CConclusion Recommendation Implementation
Timeframe (years)
The piping, pipe supports, sump pump
fittings, and electrical items within the
meter vaults also showed various defects
that appear to be relate d to the
groundwater infiltration, particularly if it is
brackish.

1. Address the electrical connections
within the meter vaults (meter
ground cables and power for
sump pump). Replace corroded
connectors with corrosion -
resistant materials and take
precautions for galvanic corrosion
between dissimilar metals.

2. Replace the cam- lock fittings for
the sump pump in the south
meter vault.

3. Assuming that the groundwater
entering the meter vaults is
brackish, use materials and
coatings suitable for a marine
environment for all items within
the vaults.

4. Consider whether the groundwater
may also be aggressive to the
buried DIP force mains within the
pump station site, review the
construction details for the force
mains to determine whether
adequate corrosion protection
was provided for the buried pipe.

Consider conducting field
evaluations to determine the
corrosivity of the soil and/or the
condition of the buried DIP.
3 to 5
Reed Electric identified several minor- to
moderate-severity vibration issues and
recommended that these be addressed
during the next planned outage
Reed Electric recommended additional
testing during the next planned outage. 0 to 2

05/13/2025 C9 696 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Executive Summary 5

Table ES-3. Raceway Pump Station Assessment Summary
CConclusion Recommendation Implementation
Timeframe (years)
There is potential infiltration/exfiltration
at cracks in the concrete reservoir. The
concrete surface is in good condition
though. The concrete has spalled at the
base of the guardrail around the concrete
reservoir due to a lack of insulation
between the aluminum and concrete
material.

Seal points of infiltration/exfiltration within
the concrete reservoir Install a grout or
sealant at the base of the aluminum posts
and slope it so that water runoff is allowed
to flow away from the embedded section. 3 to 5
The coating on the electrical box supports
has failed and the concrete is damaged at
the base. There is corrosion staining on
the electrical box and conduits.

Replace corroded conduits. Recoat
electrical equipment as needed. 3 to 5
The surface of the piping is in good
condition, with the majority of the coating
(about 90% ) intact. The coating on the
flange near the Pump 3 discharge pipe
has failed though, leading to the exposed
metal surface to have moderate
corrosion.

Recoat piping and associated equipment
as needed.
3 to 5
At most of the testing locations, the pipe
and fittings are in good condition. There
were a few locations that showed wall
thickness outside the manufacturing
tolerances by what is consid ered a minor
degree. The pipe spools that showed this
increased wall thickness loss were
assumed to have been manufactured
thicker than Class 53 (minimum required
for flanged DIP per AWWA C115). Overall,
while there may have been a minor
thickness loss at a few locations, it does
not appear to have been to a significant
degree.

Recoat or replace the corroded metal
flange near the Pump 3 discharge pipe.
3 to 5

05/13/2025 C9 697 of 1078
V&A Project No. 15-0024 Introduction 6

1.0 INTRODUCTION
V&A Consulting Engineers, Inc. (V&A) was retained by Carollo Engineers, Inc. (Carollo) to conduct a condition assessment of three pump stations for the City of Vista (City) and the Buena Sanitation District (District). The pump stations of interest are the Buena Vista Pump Station (BVPS), the Buena Creek Pump Station (BCPS), and the Raceway Pump St ation (RPS). The BVPS is located in Carlsbad, California, and the BCPS and the RPS are located in Vista, California. These pump stations are part of four pump stations that convey water to the Encina Wastewater Authority’s (EWA) Water Pollution Control Facility. The EWA operates these pump stat ions for the City and the District. The BVPS and RPS are in the City service area, and the BCPS is in the District service area. Figure 1—1 is an aerial view of the pump station locations.

Figure 1—1. Aerial Map Showing Locations of the
Buena Creek, Buena Vista, and Raceway Pump Stations
N N
05/13/2025 C9 698 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Introduction 7

The City and District wish to assess the condition of assets in the wastewater conveyance system for rehabilitation planning and providing the necessary upgrades to improve the safety, reliability, and efficiency of the stations, and meet current applic able treatment codes, standards, and guidelines.

V&A’s assessments are intended to provide informat ion to assist Carollo in preparing Preliminary Design Reports for the three pump stations. The assessment consisted of the following actions, which were carried out between September 2015 and January 2016:

x Visual evaluation of the concrete surfaces an d metal piping and appurtenances in the BCPS and BVPS dry wells using digital photographs to document notable observations. x Visual evaluation of coatings on concrete and metal structures x Pit depth measurement on corroded metallic surf aces in the BCPS and BVPS dry wells and on above grade RPS piping.
x Pipe wall thickness measurements using an ultrasonic testing gage for dry well piping in the BCPS and BVPS dry wells, and on above grade piping at the RPS. x Rating the evaluated concrete and metal surfaces using the VANDA ® Concrete and Metal Condition Index
x Motor and pump vibration analysis by Reed Electric at BCPS and BVPS x In-situ soil resistivity testin g along the 18-inch diameter force main and 14-inch diameter excess effluent pipeline alignments for the BC PS. Cursory foreign utility investigation along both ductile iron pipelines for potential cathodically protected structures. After potholing over the pipeline, collect three soil samples at pipe depth for corrosivity analysis. Soil samples were laboratory tested for as-received and saturated (minimum) soil resistivity, pH, and soluble chloride, sulfate, and bicarbonate ion concentrations.

The assessment approach is described in more detail in Section 2.0.

05/13/2025 C9 699 of 1078
V&A Project No. 15-0024 Assessment Approach 8

2.0 ASSESSMENT APPROACH
V&A uses both qualitative and quantitative means to evaluate structures and their components. The condition assessment utilized the methods and techniques described in this section.

2.1 Access
The dry wells accessed during the assessments are not confined spaces, yet V&A personnel wore 4- gas monitors as a precautionary measure. Piping and concrete surfaces intended for evaluation were accessible while standing on the dry well floors. A ladder was used when needed to reach and evaluate concrete and metal surfaces. Above grade piping and other components were easy to access on foot and did not require ladders or scaffolding. The assessment team members wore the appropriate personal protective equipment while on-site, which included steel-toed shoes, safety glasses, gloves, and hard hats.

2.2 Visual Assessment
The visual assessment focused on the condition of concrete and metal surfaces. Observations such as exposed aggregate, cracks, and evidence of corrosion were recorded when found, supplemented with digital photographs. Pipeline joints were evaluated for offsets, leaks, gaps, and other notable items if found. It should be noted that the assessment of concrete for this project was limited to a visual evaluation. Physical and quantitative testing was not performed for the concrete surfaces. 05/13/2025 C9 700 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Assessment Approach 9

2.3 Ultrasonic Thickness Testing
V&A conducted ultrasonic thickness testing on the piping in the dry wells at the BCPS and BVPS, and on the above-
grade header piping at the RPS. Ultrasonic thickness
testing is a non-destructive evaluation technique that
allows for the determination of metal wall thickness. High- frequency sound waves are transmitted through one side
of a metal wall from a transducer. When sound waves
reach the other side of the metal wall, a fraction of the waves will echo back to the transducer. The metal
thickness is determined by reco rding the time it takes for the sound wave to travel through the metal and return.

V&A used an Olympus ultrasonic thickness gauge to obtain thickness measurements for the metallic piping (Photo
2-1). Prior to taking measurements, the gauge was
calibrated to the velocity of sound in ductile iron or steel, as appropriate. The type of testing that was conducted is known as A-scan, which gives the wall thickness at a single point at each measurement location. It should be noted
that the wall thickness at other locations may vary. Test locations were chosen to provide a representative
condition of the entire pipe surface. Testing was performed on accessible piping (i.e. able to be reached without a ladder/scaffolding/confined space entry).

2.3.1 Wall Thickness Loss Analysis
The classes and nominal thicknesses of the pipe and fittings used at the pump stations were unknown. The wall thickness loss was calculated based on the nominal thickness and the associated casting tolerance from the ductile iron pipe (DIP) standards that were assumed to be applicable. The nominal thickness defines each class of pipe or fitting and is used in specifying and ordering. The casting tolerance is a “minus” tolerance given by the applicable standard, allowing the pipe or fitting to be thinner than the nominal thickness at manufacture. If the measured thicknesses are within the casting tolerance, variations in thickness at a gi ven location are not necessarily an indicator of corrosion.

Since the pipe spools that were tested had thread ed flanges or grooved ends, they are assumed to have been made from Class 53 ductile iron pipe, or thicker, per the requirements of AWWA C115, "Flanged Ductile-Iron Pipe with Threaded Flan ges," and AWWA C606, “Grooved and Shouldered Joints.” It should be noted that the piping was not evaluated for pressure or other loading considerations. Higher pressures, for example, coul d have dictated a need for pipe that was thicker than the minimum class allowed by these standards, which are based on manufacturing considerations.

Photo 2-1. Olympus Ultrasonic
Thickness Gauge

05/13/2025 C9 701 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Assessment Approach 10

In addition to the ductile iron pipe spools that we re tested, steel rectangular suction lines at the BVPS and ductile iron elbows at the RPS were also tested. The nominal thickness for the steel rectangular components was unknown, so they were assumed to have been fabricated from fractional-inch plate. The nominal thickness and ca sting tolerance for the ductile iron elbows were taken from AWWA C110, "Ductile-Iron and Gray-Iron Fittings,” for Class 250 ductile iron fittings.

2.4 Pit Depth Measurements
Where pitting was observed on the exterior of
the piping, pit depths were measured using a
handheld pit depth gage (Figure 2—1). The
gage is held in a vertical position above the pit
to be measured with the lower edge flush
against the metal surface. The claw is inserted
into the pit. The pit depth is read on the dial at
the right hand side of the gage.

2.5 Vibration Analysis
Reed Electric & Field Services was retained to pe rform vibration tests for the motors and pumps at the BCPS and BVPS. The RPS has submersible pump s, so testing was not performed there. The intent of testing is to screen for maintenance and repair activities. The vibration tests were performed for Pumps and Motors 1, 2, 3, 4, and 5 at the BCPS and the BVPS. Motor 3 at the BCPS experienced Variable Frequency Drive (VFD) or other electrical issues, and the testing was aborted.

A four-channel data recorder and analyzer were used with three magnetic-mount accelerometers and a laser speed tachometer to monitor vibration and motor speeds in revolutions per minute (rpm).

Sensors were mounted as shown in Figure 2—2 on the motor upper bearing, motor lower bearing, pump upper bearing, and pump lower bearing in th e in-line, perpendicular, and axial directions.

System control limitations allowed data to be collect ed only at certain pump speeds for several test points. The following data was recorded for each test performed at both pump stations:

x Overall velocity and displacement vibration
x Velocity spectrum plots
x Filtered amplitude/phase measurements where the tachometer was available

The test observations and Reed Electric’s recommendations for future monitoring and evaluation are presented in the Findings sections for the BCPS and the BVPS assessments.

Figure 2—1 . Standard Pit Depth Gage
05/13/2025 C9 702 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Assessment Approach 11
Figure 2—2. Typical Reed Electric Vibratio n Test Monitoring Sites on Pump Motors

2.6 In-Situ Soil Resistivity

2.6.1 Wenner Four-Electrode Method: General Information Understanding how easily current will travel thro ugh a medium surrounding a metallic object is important in evaluating the corrosivity of the envi ronment. Resistivity is an inverse measure of the ability of a soil to conduct an electric current, wi th higher resistivity resulting in a lesser degree of current flow. Corrosion rate depends on current flow between a metal and the adjacent medium.

Normally, the corrosion activity on metals in soil increases as soil resistivity decreases.

Soil resistivity measurements were conducted in accordance with ASTM G57, “Standard Test Method for Field Measurement of Soil Resistivity Using the Wenner Four-Electrode Method.” The Wenner method involves the use of four metal electrodes (p ins) driven into the ground along a straight line, equidistant from each other, as shown in Figure 2—3. At each of the two excavation locations, soil resistance measurements were recorded at pin spacings of 5, 7.5, 10, 15, and 20 feet.

Motorr
UUpperr
Motorr
LLowerr
Pumpp
UUpperr
Pumpp
LLowerr
05/13/2025 C9 703 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Assessment Approach 12
An alternating current from the soil resistance meter causes a current to flow through the soil between the outside pins C1 and C2. The soil resistance creates a voltage gradient, which is proportional to the average resistance of the soil mass to a depth equal to the distance between pins. The voltage drop is then measured across pins P1 and P2, and the soil resistance (in ohms) is calculated by the soil resistance meter. Resistivity of the soil (in ohm-cm) is then computed from the instrument reading using the procedure described in Sections 2.6.2 and 2.6.3.

Figure 2—3. Wenner Four-Electrode Method Schematic

2.6.2 Soil Resistivity Calculation – to Depth
In the Wenner four-electrode method, the average resistivity of the soil mass below the pins, to a depth equal to the pin spacing, is calculated with the equation ρ = 2 ∙ π ∙ A ∙ R,
where ρ = average soil resistivity to a depth of A (ohm-cm), A = distance between electrodes (cm),
R = soil resistance to a depth of A, soil resistance meter reading (ohm), and π = 3.14 (approximately).
05/13/2025 C9 704 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Assessment Approach 13

The resulting resistivity value represents the average resistivity of the soil below the pins to a depth equal to the pin spacing. This average resistivity va lue includes the effect of soil layers near the surface. The Barnes layer method, described below in Section 2.6.3, allows the resistivity of each soil layer below grade to be calculated without the effect of shallower layers.

2.6.3 Soil Resistivity Calculation – per Layer (Barnes Method) The Wenner four-electrode method, described abov e in Sections 2.6.1 and 2.6.2, determines the average soil resistivity from grade to a depth equal to the pin spacing. These results can be expanded using the Barnes layer meth od to remove the effect of shal lower soil layers and arrive at the resistivity of each soil layer individually. For example, the average resistivity of the soil layer between 5 feet and 10 feet deep may be calc ulated using the four-electrode resistance measurements for the 5- and 10-foot depths.

The results of the Barnes layer calculations are used to evaluate the corrosivity of the soil in lieu of the average resistivity from grade to a given depth. The Barnes layer method isolates the layer of soil that a particular structure will be in contact with, whil e neglecting the soil in layers that will not be in contact with the structure. The soil layers that are no t in contact with the structure will have little to no effect on the corrosion rate of the structure. Soil corrosivity as a function of soil resistivity is discussed in Section 2.7.

In the Barnes layer method, the soil layer resistance (RA-B) is first calculated using the equation

RA-B = (RA ∙ RB) / (RA – RB),

where RA-B = soil layer resistance from depth A to depth B (ohms), RA = soil resistance to depth A, soil resistance meter reading (ohms), and RB = soil resistance to depth B, soil resistance meter reading (ohms).

Next, the average soil layer resistivity (ρA-B) is calculated using the equation

ρA-B = 2 ∙ π ∙ (B – A) ∙ RA-B,

where ρA-B = average resistivity of soil layer between depth A and depth B (ohm-cm), A = depth below grade to the top of the soil layer (cm), B = depth below grade to the bottom of the soil layer (cm), π = 3.14 (approximately), and
RA-B = soil layer resistance from depth A to depth B (ohms), as determined above.

05/13/2025 C9 705 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Assessment Approach 14

2.7 Soil Sample Analysis
A wide variety of water-soluble salts is typically f ound in soils. Two soils having the same resistivity may have significantly different corrosion characteri stics, depending on the specific ions available.

The major constituents which accelerate corrosion are bicarbonate ions, chloride ions, sulfate ions, and the pH (acidity) of the soil. Potholing was performed to collect soil samples near the depth of the pipe invert. These soil samples were sent to a Project X Corrosion Engineering laboratory in Murrieta, California to be tested for resistivity and the major corrosive constituents described below.

2.7.1 Resistivity
The in-situ soil resistivity testing per ASTM G57 discussed in Section 2.6 determines the soil resistivity at several different depths at a poin t in time. The minimum soil resistivity provides information about the soil during wet-weather conditions.

Soil resistivity is primarily dependent on the ion and moisture content of the soil. Higher levels of ions in the soil lower the soil resistivity. Additional mois ture decreases the soil resistivity up to the point where the maximum solubility for the dissolved ioni c compounds is achieved. Beyond this point, an increase in moisture increases the resistivity as the ions become more and more diluted. The decrease in soil resistivity is attributed to the pres ence of ions in the “as-received” soil going into solution and providing a less resistive path for current flow.

The following table correlates resistivity values wi th degree of corrosivity. The interpretation of corrosivity correlation to soil resistivity varies somewhat among corrosion engineers. However, Table 2-1 is a generally accepted guide and is based upon corrosivity rankings presented in “Corrosion Basics – An Introduction,” pg. 191 (1984), published by the National Association of Corrosion Engineers (NACE).

Table 2-1. Effect of Resistivity on Soil Corrosivity
SSoil Resistivity
((ohm--ccm) DDegree of Corrosivity
< 500 Very high
500 – 1,000 High
1,000 – 2,000 Moderate
2,000 – 10,000 Mild
> 10,000 Negligible

2.7.2 Bicarbonate Ions
High concentrations of bicarbonates tend to decrease soil resistivities. Bicarbonates are not directly aggressive to buried metal, but the lower-resistivity environments can promote corrosion activity. 05/13/2025 C9 706 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Assessment Approach 15

2.7.3 Chloride Ions
Chloride ions found in soils tend to break down otherwise protective surface deposits and can result in corrosion of buried metallic structures and reinforcing steel in concrete structures. Table 2-2 shows the effect of chloride ions on the corrosivit y of the soil. These ranges are generally accepted by the corrosion engineering community.

Table 2-2. Effect of Chloride Ions on Soil Corrosivity
WWater--ssoluble Chloride
CConcentration (mmg/kg)) DDegree of Corrosivity
> 5,000 Very high
1,500 – 5,000 High
500 – 1,500 Moderate
100 – 500 Mild
< 100 Negligible

2.7.4 Sulfate Ions
Sulfate ions found in soils can be highly aggressive to the portland cement matrix in concrete by combining chemically with certain constituents of the cement, principally tricalcium aluminate.

Typically, this reaction is accompanied by expansio n and eventual disruption of the concrete matrix, and can result in corrosion of reinforcing steel in concrete structures. High sulfate levels also reduce soil resistivity, which can promote corrosion of buried metallic structures. Table 2-3 shows the effect of sulfate ions on the corrosivit y of the soil. These ranges are ge nerally accepted by the corrosion engineering community.

Table 2-3. Effect of Sulfate Ions on Soil Corrosivity
Water--soluble Sulfate
Concentration (mmg/kg) Degree of Corrosivity
> 2,000 Very high
1,000 – 2,000 Moderate
< 1,000 Negligible

2.7.5 Soil pH
Acidity, as indicated by the pH value, is another im portant factor of soil wi th respect to corrosivity.

Lower pH (more acidic) will result in a greater de gree of corrosivity with respect to buried metallic and concrete structures. When pH increases above 7.0 (the neutral value), the conditions become increasingly more alkaline. In alkaline environments , steel forms a protective layer on its surface.

This is referred to as passivation. V&A developed Table 2-4, which correlates the effect of pH on the rate of corrosion for buried steel or concrete structures.

05/13/2025 C9 707 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Assessment Approach 16

Table 2-4. Effect of pH on Soil Corrosivity
SSoil pH Degree of Corrosivity
< 5.5 High

5.5 – 6.5 Moderate

6.5 – 7.5 Mild
> 7.5 Negligible

2.8 VANDA ® Metal Condition Index
The VANDA Metal Condition Index was created by V&A to provide consistent reporting of metal corrosion damage based on qualitative, objective cr iteria. Condition of corrosion can vary from Level 1 to Level 4 based upon visual observations and field measurements, with Level 1 indicating the best condition and Level 4 indicating severe damage.

Table 2-5. VANDA
® Metal Condition Index
Condition
Rating Description Representative
Photograph
Level 1 Little or No Corrosion
x Loss of Wall Thickness %: None
x Pitting Depth (as % of Wall Thickness): None to Minimal x Extent (Area) of Corrosion: None

Level 2 Minor Surface Corrosion
x Loss of Wall Thickness %: < 25%
x Pitting Depth (as % of Wall Thickness): < 25%
x Extent (Area) of Corrosion: Localized

Level 3 Moderate to Significant Corrosion
x Loss of Wall Thickness %: 25%–75%
x Pitting Depth (as % of Wall Thickness): 25%–75%
x Extent (Area) of Corrosion: 25%–75%

Level 4 Severe Corrosion; Immediate Repair/Replacement Needed x Loss of Wall Thickness %: > 75%
x Pitting Depth (as % of Wall Thickness): 75% or More
x Extent (Area) of Corrosion: Affects Most or All of Surface

© 2016 V&A Consulting Engineers, Inc. All rights reserved.

05/13/2025 C9 708 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Assessment Approach 17

2.9 VANDA ® Concrete Condition Index
The VANDA Concrete Condition Index was created by V&A to provide consistent reporting of corrosion damage based on qualitative, objective criteria. Condition of corrosion can vary from Level 1 to Level 4 based upon visual observations and field measurements, with Level 1 indicating the best condition and Level 4 indicating severe damage.

Table 2-6. VANDA® Concrete Condition Index
CCondition
RRating Description Representative
Photograph
Level 1 None/Minimal Damage to Concrete
x Hardness: No Loss
x Surface Profile: No Loss
x Cracking: Shrinkage Cracks
x Spalling: None
x Reinforcing Steel (Rebar): Not Exposed or Damaged

Level 2 Damage to Concrete Mortar
x Hardness: Damage to Concrete Mortar
x Surface Profile: Some Loss
x Cracking: Thumbnail Sized Cracks of Minimal Frequency x Spalling: Shallow Spalling of Minimal Frequency,
Related Rebar Damage
x Reinforcing Steel (Rebar): May Be Exposed but Not Damaged

Level 3 Loss of Concrete Mortar/Damage to Rebar
x Hardness: Complete Loss
x Surface Profile: Large Diameter Exposed Aggregate
x Cracking: ¼-inch to ½-inch Cracks, Moderate Frequency x Spalling: Deep Spalling of Moderate Frequency,
Related Rebar Damage
x Reinforcing Steel (Rebar): Exposed and Damaged, Can Be Rehabilitated

Level 4 Rebar Severely Corroded/Significant Damage to Structure x Hardness: Complete Loss
x Surface Profile: Large Diameter Exposed Aggregate
x Cracking: ½-inch Cracks or Greater, High Frequency
x Spalling: Deep Spalling at High Frequency, Related Rebar Damage x Reinforcing Steel (Rebar): Damaged or Consumed,
Loss of Structural Integrity

© 2016 V&A Consulting Engineers, Inc. All rights reserved.

05/13/2025 C9 709 of 1078
V&A Project No. 15-0024 Buena Creek Pump Station and Pipelines 18

3.0 BUENA CREEK PUMP STATION

AND PIPELINES
The BCPS was constructed circa 2002 and has a capacity of 8.8 million gallons per day (mgd). The collection system for the District culminates at this station, and is conveyed to the Buena outfall and the EWA Water Pollution Control Fa cility. V&A conducted a visual assessment, ultrasonic thickness testing, in-situ soil resistivity surveys, and soil sampling at the BCPS and along the downstream pipeline alignments. The visual assessment and ultrasonic thickness testing were conducted on September 10, 2015. Reed Electric & Field Service conducted the pump and motor vibration tests on September 10, 2015. The corrosivity of the so il environment that the pump station excess effluent and force main pipelines are buried in was also assessed. This was done by performing in- situ resistivity testing on January 12, 2016, which included a foreign utility investigation and soil sample analysis. The results of these studies are presented below.

3.1 Dry Well Visual Assessment
The BCPS has five pumps, each rated 4,500 gallons per minute. Pumps 1 and 2 drain the West Wet Well and Pumps 3, 4, and 5 drain the East Wet We ll. The concrete walls, floor, and ceiling of the Pump Room are in good condition. No major spalls or cracks were observed. A few isolated hairline cracks with groundwater leak deposits were seen, predominantly on the south wall. The leachate mineral deposits did not show the brownish staining indicative of reinforcing steel corrosion (Photo 3-1 and Photo 3-2).

Photo 3-1
. Groundwater leachate deposits
along hairline cracks, south wall.

Photo 3-2. Groundwater seepage deposits on
Pump Room wall at hairline cracks.
05/13/2025 C9 710 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Creek Pump Station and Pipelines 19 The mounting of the pump motors appears to be a significant issue with respect to seismic loading.

The motors and pumps form an inverted-pendulu m arrangement that is only supported by the suction and discharge flanges on each pump (Photo 3-3 and Photo 3-4). It should be noted that the condition assessment did not focus on seismic and structural issues, but this particular issue was apparent based on V&A’s experience with other pump stations.

Photo 3-3. Typical pump motor supported by
pump volute flanges.

Photo 3-4. Typical pump motor supported by
pump volute flanges.

A variety of minor defects on equipment in th e Pump Room was documented. Minor corrosion staining and hairline cracking was seen on the Pu mp 3 support pedestal (Photo 3-5). Coating failure and corrosion were observed on a discharge piping support at Pump 4 (Photo 3-6). These features indicate minor leaks from above the support pedestals that collect on flat surfaces.

Photo 3-5. Minor cracks and corrosion
staining on Pump 3 support pedestal.

Photo 3-6. Coating failure and corrosion on a
Pump 4 discharge piping support.
05/13/2025 C9 711 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Creek Pump Station and Pipelines 20 Overall the coatings on the metal piping and appu rtenances are intact. Minor coating delaminations were seen, but the exposed metal surfaces, if not di rectly exposed to water, are not corroded (Photo 3-7 and Photo 3-8).

Photo 3-7. Small coating loss on Pump 1
electric motor housing.

Photo 3-8. Delaminated coating and exposed,
uncorroded metal substrate.

Leakage appears to have occurred at a flange bolt on Pump 3, which is evident from and corrosion staining (Photo 3-9). Wall penetrations of pump su ction piping for Pumps 2, 3, 4, and 5 have leak stains running down the wall. A representative example from Pump 3 is shown in Photo 3-10.

Photo 3-9. Leak along flange at bolt. Photo 3-10. Wall staining at Pump 5 suction pipe at wall penetration.

The only active leak in the Pump Room was on th e west wall behind ventilation ducting (Photo 3-11 and Photo 3-12). It may be a supply line to an up stairs bathroom in the Pump Station, and is not associated with the discharge piping and pump systems. A 1-inch diameter copper pipe extending from ceiling to floor on the west wall a few feet south of the active leak is corroded at a tee fitting adjacent to a grounding cable connection (Photo 3- 13). The corroded area was high on the wall and could not be accessed, but appeared to be a connecti on from a slightly larger pipe entering the wall at this point.
05/13/2025 C9 712 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Creek Pump Station and Pipelines 21 Photo 3-11. Active leak along west wall of
Pump Room. Not associated with pump
discharge and suction piping.

Photo 3-12. Active leak along west wall of
Pump Room. Not associated with pump
discharge and suction piping.

Photo 3-13. Corroded copper piping on Pump
Room west wall.

Four of the five galvanized pipe support bracke ts for the pump discharge piping along the Pump Room walls are loose and are providing little support. The fourth support in the effluent direction was rattling during pump operation and the coating is being damaged from the vibration. Overall, no significant corrosion staining or corrosive exfoliation of piping or appurtenances was observed in the Pump Room.
05/13/2025 C9 713 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Buena Creek Pump Station and Pipelines 22

3.2 Ultrasonic Thickness Measurements
The ultrasonic thickness data is summarized in Tabl e 3-1. As shown in the table, the wall thickness loss for the ductile iron pipe and fittings, at th e locations that were tested, was mostly within manufacturing tolerances. There were four loca tions that the wall thickness was outside the tolerances, yet by what is considered a mino r degree. The maximum wall thickness loss was calculated to be 19%. However, the wall thicknes s at these locations was outside the manufacturing tolerances by only 0.014 inches.

Table 3-1. Buena Creek Pump Station Ultrasonic Thickness Data Summary LLocation Dia.
(in.)
Measured Thickness (in.) Assumed Pipe
Specifications Max.

Wall
Loss
(in.)
Max.

Wall
Loss
Min. Avg. Max. Class
Nom.

Thick-
ness
(in.)
Cast--
ing
Tol.
(in.)
Pump 1 suction, upstream 12 0.440 0.453 0.477 55 0.46 −0.06 0.020 4% Pump 1 suction, downstream 12 0.365 0.388 0.413 53 0.40 −0.06 0.035 9% Pump 2 suction, upstream 12 0.521 0.527 0.534 56 0.49 −0.06 (a) (a) Pump 2 suction, downstream 12 0.326 0.337 0.351 53 0.40 −0.06 0.074 19% Pump 3 suction, upstream 12 0.388 0.398 0.423 53 0.40 −0.06 0.012 3% Pump 3 suction, downstream 12 0.357 0.374 0.394 53 0.40 −0.06 0.043 11% Pump 4 suction, upstream 12 0.344 0.375 0.399 53 0.40 −0.06 0.056 14% Pump 4 suction, downstream 12 0.359 0.384 0.397 53 0.40 −0.06 0.041 10% Pump 5 suction, upstream 12 0.326 0.364 0.395 53 0.40 −0.06 0.074 19% Pump 5 suction, downstream 12 0.342 0.371 0.395 53 0.40 −0.06 0.058 15% Pump 4 discharge 12 0.352 0.360 0.370 53 0.40 −0.06 0.048 12% Pump 5 discharge 12 0.337 0.349 0.358 53 0.40 −0.06 0.063 16% Lower header between Pumps 4 and 5 12 0.409 0.424 0.451 54 0.43 −0.06 0.021 5% Surge tank riser 12 0.343 0.369 0.394 53 0.40 −0.06 0.057 14% Force main on S. wall, upstream of meter 14 0.403 0.424 0.438 54 0.45 −0.07 0.047 10% Force main on S. wall, downstream of meter 14 0.367 0.394 0.420 53 0.42 −0.07 0.053 13% Flow meter bypass along south wall 14 0.353 0.353 0.353 53 0.42 −0.07 0.067 16% Lower header between Pumps 3 and 4 24 0.506 0.522 0.536 56 0.56 −0.07 0.054 10% Lower header between Pumps 2 and 3 24 0.560 0.576 0.645 56 0.56 −0.07 0.000 0% Lower header between Pumps 1 and 2 24 0.464 0.526 0.557 56 0.56 −0.07 0.096 17% Lower header west of Pump 1 24 0.515 0.531 0.549 56 0.56 −0.07 0.045 8% Force main along west wall 24 0.502 0.523 0.543 56 0.56 −0.07 0.058 10% Notes
(a) Measured thickness within manufacturing tolerances or greater than nominal; wall loss not reported.

05/13/2025 C9 714 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Buena Creek Pump Station and Pipelines 23

3.3 Vibration Analysis Results
Vibration testing was performed on Motors and Pumps 1, 2, 4, and 5. Pump 3 was not operational and was not tested. The pumps were run between 78 to 87% speed during the test. System control limitations and high cavitation vibration at lower lo ads dictated that data only be collected at those speeds. General observations of the testing indicate that vibration levels are high on most motor and pump test locations, with many exceeding Internati onal Standards Organization (ISO) and Hydraulic Institute acceptance standards for operating levels. The high readings were directional, primarily in the in-line direction on both the motors and the pu mps. The highest readings on each pump system were typically in the pump lower bearing area. Pr edominant vibration frequency peaks were at two times the running speed. Reed theorizes that the stiffness of the pipe and pump supports may have a significant bearing on the severity of vibratio n. There was no indication of high-frequency mechanical or electrical peaks on any of the test points, indicating that there is minimum hydraulic noise and no apparent VFD issues. A summary of th e testing results is presented in Table 3-2. The full report from Reed Electric is attached is Appendix A.

Table 3-2. Buena Creek Pump Station Vibration Analysis Results MMotor OObservation
Motor/Pump 1 High directional levels in the inline direction from the motor bearings down to the pump bearings. This motor generally had the highest readings at all test points.

Motor/Pump 2 High directional levels in the inline direction from the motor bearings down to the pump bearings, but at lower levels than Pump 1.

Motor/Pump 3 Not tested.

Motor/Pump 4 Pump bearings showed a higher perpendicular relationship than the other pumps. While performing testing, the suction piping support for Pump 4 was found to be loose.

Motor/Pump 5 Generally comparable or lower levels of vibration compared to the other three pumps that were tested.

3.4 In-situ Soil Resistivity Results
Figure 3—1 shows the locations where soil resistivity testing was performed along the excess effluent and force main pipelines. A summary of the in-situ so il resistivity results is presented in Table 3-3.

The complete list of in-situ soil resistivity results is presented in Appendix B. The “resistivity to depth” at a given test site is the resistivity of the soil mass from grade down to the designated depth. Per Section 2.6, resistivities of 10,000 ohm-cm and greater can be considered negligible with regards to corrosion. The resistivities for the layers down to a depth of 7.5 - 10 feet on average are between 2,766 – 2,696 ohm-cm, with locations as low as 287 ohm-cm. This means the majority of the tested soils along the alignment are moderately to highly corrosive, with areas of very highly corrosive conditions. Per the provided record drawings, the de pth of cover for the pipelines ranges from about 5 to 7.5 feet below grade.

05/13/2025 C9 715 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Creek Pump Station and Pipelines 24 Figure 3—1. Soil Resistivity Testing Site Plan
Table 3-3. Summary of In-Situ Soil Resistivity Test Results DDepthh
(feet))
Resistivityy too Depthh (ohm--cm)
Layerr
(feet))
Resistivityy off Layerr (ohm--cm)
Average Minimumm Maximumm Average Minimum Maximum
5 3,015 335 14,995 0 - 5 3,015 335 14,995

7.5 2,766 287 11,563 5 - 7.5 2,657 187 10,249
10 2,696 287 10,208 7.5 - 10 3,075 271 15,052
15 2,301 259 8,905 10 - 15 1,969 215 7,170
20 1,961 268 8,235 15 - 20 2,189 230 11,462
Alll Depths 2,548 259 14,995 Alll Layers 2,581 187 15,052 05/13/2025 C9 716 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Creek Pump Station and Pipelines 25 Foreign utility investigation revealed a 16-inch co ncrete mortar lined and tape wrapped pipeline owned by Olivenhain Water District on Faraday Av enue (as noted on the brass tag at the cathodic protection test station). Based on the type of test station and the results of the potential testing, the pipeline is cathodically protected with a galvanic system. Current output from galvanic anode beds is low compared to that of typical impressed cu rrent anode beds, so galvanic systems are not considered to be a risk of interference.

Power utilities are primarily underground along the alignment routes evaluated. High voltage power lines cross the pipeline alignments on Melrose Dr ive between Sycamore Avenue and Mountain Pass Circle. High voltage alternating current can be reas on for concern when power lines parallel buried pipelines for long distances. This short crossing is noted, but is not of concern.

3.5 Soil Sample Analysis Results
The locations of the potholing where soil samples were collected are shown in Figure 3—2. Table 3-4 presents a summary of the laboratory analysis resu lts. Based on the guidelines in Section 2.7 the three soil samples were high to moderately corrosi ve. Site 3 is the most corrosive considering the high chloride concentration.

Figure 3—2 Potholing Location Site Plan
05/13/2025 C9 717 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Buena Creek Pump Station and Pipelines 26

Table 3-4. Summary of Laboratory Soil Analysis Results
PPothole
Location
Depth
(ft)
Resistivity (ohm-cm) Chemical Data /
Rating Overall
Corrosivity
Rating As--
received Minimum pH Sulfate
(mg/kg)
Chloride
(mg/kg)
Bicarbonate
(mg/kg)
1 4 67,000 670 6.7 234 334 330 High
2 3.5 201,000 1,005 6.8 108 564 133.2 Moderate
3 3.5 603,000 2,144 7.7 24 2,904 180 High

3.6 Conclusions
Based on the results of the condition assessment, V&A presents the following conclusions:

1. The evaluated concrete surfaces are in good condition, rated VANDA Level 1.

2. Metal surfaces are in good condition with th e majority of the coating (about 90%) intact.

There is some copper piping that is significantly corroded (VANDA Level 3).

3. At most of the testing locations, the DIP is in good condition and is rated VANDA Level 1.

There were a few locations that showed wall thickness outside the manufacturing tolerances by what is considered a minor degree. No significant exterior corrosion or leaks were observed on the rest of the piping in the dr y well, which was outside the ultrasonic testing areas.

4. The inverted pendulum arrangement of the motor and pumps appears to be a significant issue with respect to seismic loading. However, seismic/structural analysis was not part of the project scope of work.

5. Vibration levels are high on most motor and pu mp test locations, with many exceeding ISO and Hydraulic Institute acceptance standards for operating levels.

6. The buried excess effluent and force main DI P are within a moderately to very highly corrosive soil environment.

05/13/2025 C9 718 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Buena Creek Pump Station and Pipelines 27

3.7 Recommendations
Based on the conclusions of the condition assessment, V&A presents the following recommendations:

1. The evidence of groundwater infiltration on the concrete walls and the corrosive soil environment around the pump station warrant additional testing in the concrete pump room.

Testing to be considered includes:
a. Concrete core analysis to identify corrosion stimulants and concrete characteristics b. Determining placement of reinforcing steel
c. Identify corrosion potential on reinforcing steel and visually verify condition

2. Seal points of infiltration at the construction joints. It is recommended this be done after performing additional concrete testing to de termine the appropriate repair/rehabilitation approach.

3. Repair damaged coating on mechanical equipment and piping as needed. Prepare surfaces to remain per SSPC SP 2 to 3. Coat with a 100% solids epoxy or polyurethane coating system, such as Carboline Carboguard 890, PPG Amercoat Amerlock 400, or Tnemec Series N69 at 2 to 3 mils dry film thickness.

4. Clean the surfaces of the copper piping and determine if the replacement of copper piping is warranted.

5. Evaluate the seismic vulnerability of the motor and pump arrangement.

6. Reed Electric recommended the following actions for the pumps and motors based on the vibration analysis results:
a. #3 Motor & Pump: This unit had VFD drive or other electrical issues during the test. It will need to be scheduled for a retest when feasible.
b. The evidence of high vibration on all motor and pump structures warrants a full structural mode shape analysis, to allow proper definition of any resonance issues as they relate to structure, and should result in effective recommendations to adjust or change the supports, etc., to reduce the effect.
c. #1 Motor & Pump – The extremely high levels on this unit warrant prioritized scheduling of detailed analysis and correction. In the meantime, the stiffness of the pump supports should be inspected for rigidity (see typical pump supports, Figures 4 & 5).
d. #2 Motor & Pump – The high levels on this unit warrant scheduling of detailed analysis and correction. In the meantime, the stiffness of the pump supports should be inspected for rigidity.
e. #4 Pump – This units’ suction piping support was found loose, and should be adjusted.

7. Consider cathodic protection for buried metal pipi ng if it is to remain in service for the next 20 years. If a new pipeline is to be installed, alternative materials to metal or concrete, such as plastic, should be considered.

05/13/2025 C9 719 of 1078
V&A Project No. 15-0024 Buena Vista Pump Station 28

4.0 BUENA VISTA PUMP STATION
The BVPS is a 23.1-mgd pump station originally constructed circa 1986. The pumps and piping were rebuilt circa 1994. The force main within the pump station site was reconfigured circa 2013, including the addition of two new flow meter vaults and surge tanks. V&A conducted a visual assessment and ultrasonic thickness testing at the pump station on September 9, 2015. Reed Electric & Field Service conducted the pump and motor vibration tests on September 10, 2015. The findings of these studies are presented below.

4.1 Dry Well Visual Assessment
The interior concrete surfaces of the dry well (lower level pump room) generally appeared to be in good condition and exhibited minimal evidence of degradation (Photo 4-1). However, there were some notable observations and minor, isolated defects, such as the following:

1. There were several isolated areas where there was evidence of groundwater seeping in through the exterior walls of the dry well. So me of these areas appeared to have been abandoned penetrations that have been patc hed. Some locations showed rust-colored staining (Photo 4-2).

2. At a few other locations, such as the discharge manifold penetration from Pumps 4 and 5, there was apparently some type of injection foam or epoxy that had dripped down the wall, probably during construction (Photo 4-3). No evidence of infiltration was observed though.

3. The mortar below the pump baseplates has cracked or spalled in some locations, particularly on Pumps 4 and 5 (Photo 4-4).
05/13/2025 C9 720 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Vista Pump Station 29
Photo 4-1. Typical concrete surfaces inside
BVPS dry well.

Photo 4-2. Evidence of groundwater intrusion
and rust-colored staining under
pipe penetration.

Photo 4-3. Apparent foam or epoxy injected
around pipe penetration.

Photo 4-4. Deteriorated mortar below
pump baseplates.

The coatings on the pumps, piping, and valves we re generally intact, but again there were some notable observations and defects, such as the following:

4. There were numerous small chips in the co ating in some areas, particularly on the components at lower elevations, such as the pump volutes, pump stands, valves, and pipe supports (Photo 4-5).
05/13/2025 C9 721 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Vista Pump Station 30

5. The coating has failed around the penetration of the check valve lever shafts (Photo 4-6).

This is probably due to leakage through the packing. There was minor surface corrosion of the valve body where the coating has failed.

6. The underside of the rectangular suction lines did not appear to be coated thoroughly at the wall penetrations from the wet well.

Photo 4-5. Typical coating condition on
piping at lower levels. Numerous small chips
in paint.

Photo 4-6. Coating failure and apparent
leakage on check valves.

In general, the exterior of the dry well piping was in good condition, along with the coatings as noted above (Photo 4-7). The pipe supports also appeared to be in good condition. Notable observations and defects included the following:

7. One pipe spool on the discharge header from Pumps 1 and 2 had a direct-threaded tap at the top of the pipe, with coating failure and moderate external corrosion surrounding the tap (Photo 4-8). It appears that the threaded ta p may leak. This spool was also an isolated location of internal wall thickness loss, as note d below in Section 4.3. It may be that the corrosion was caused by installation of the ta p having damaged both the coating and lining on this spool.

8. Most of the flanged joints did not exhibit sign s of leakage, but there were stains emanating from the suction flange on Pump 4 (Photo 4- 9). There was also evidence of minor leakage from some of the check valve covers (Photo 4-10).
05/13/2025 C9 722 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Vista Pump Station 31
Photo 4-7. Typical piping at upper elevations
in dry well, coated and in good condition.

Photo 4-8. Evidence of corrosion and
apparent leakage around threaded tap on 20-
inch header spool for Pumps 1 and 2.

Photo 4-9. Leakage from suction flange on
Pump 4.

Photo 4-10. Typical evidence of leakage from
check valve covers.

Other observations from the dry well included the site bathroom drain plumbing and the ventilation equipment:

9. The drain plumbing exhibited visible corrosion on the exterior and evidence of leakage. Some of the band clamps for the couplings were broken or missing (Photo 4-11).

10. One of the flanges for the ventilation ducting at the blower was missing most of the nuts and bolts, and it was misaligned by about 1/2 of an inch (Photo 4-12). 05/13/2025 C9 723 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Vista Pump Station 32
Photo 4-11. Motor room bathroom drain
piping. Corrosion evident; broken band
clamp visible at right.

Photo 4-12. Missing bolts and misalignment
at ventilation ducting flange.

4.2 Meter Vault Visual Assessments
The two meter vaults showed moderate to extens ive groundwater seepage at several locations at various heights on the walls. Most of these locations were characterized by rust-colored staining. The floor of each vault was wet during the evaluation, wi th a slight amount of puddling in some areas.

Examples of the groundwater infiltration are show n in Photo 4-13 to Photo 4-16. This water may be brackish due to proximity to a nearby creek and lagoon. The chloride content in brackish water would tend to promote corrosion of the reinforcing steel in the walls, as well as items inside the vaults that may be immersed. It should be noted that the meter vaults are only a few years old.

Photo 4-13. Groundwater seepage stains
along joint near hatch opening in north
meter vault.

Photo 4-14. Extensive seepage at mid-height
construction joint in south meter vault walls.
05/13/2025 C9 724 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Vista Pump Station 33
Photo 4-15. Deposits from seepage above
pipe penetration in south meter vault.

Photo 4-16. Active seep at the bottom of the
north meter vault.

The coating on the 24-inch DIP force main in the mete r vaults is peeling off the pipe at the concrete wall penetrations. There is surface corrosion on the DIP, particularly in the north meter vault (Photo 4-17). This coating failure and corrosion appears to be related to groundwater intrusion at the pipe penetrations. The wall penetration details shown on the “as built” drawings for the “Buena Vista Lift Station Force Main (VC-4) – Contract No. 55081” diff ered from the penetrations observed on-site.

The drawings show a sleeve with a waterstop ring embedded in the concrete, with mechanical expanding rubber seals (i.e., Link-Seals) and a sealant sealing the gap between the pipe and the sleeve. Instead the DIP force mains appear to have been directly embedded in the concrete walls and there may not be a waterstop ring. This woul d tend to explain the evidence of groundwater intrusion at the pipe penetrations.

The flow meter within each vault is equipped with a bare copper ground cable that attaches to a grounding ring at one of the meter flanges. The copper cables show a green copper oxide product on the surface, but generally appear to be intact. Th ere is greater and apparently ongoing oxidation at some of the connectors for the copper cables. Wher e the cables connect to the meter flanges, the moisture is dripping on the adjacent pipe flange and causing apparent coating failure and surface corrosion (Photo 4-18). In comparison with the corrosion observed at the connectors, the green oxide product on the cable itself does no t appear to be a significant concern. The ground cable is also zip- tied to the outside of another conduit and appears to be damaging the coating on the conduit.

Other than the isolated defects noted above, the DIP and flow meter, as well as their coatings, within each vault appear to be in good condition. However, the hold-down rods for the pipe supports in each vault may eventually cause coating failure and corros ion of the pipe at that location. The hold-down rods were applied directly over the coated DIP surface without any form of galvanic or vibration isolation (such as a rubber pad) in between.
05/13/2025 C9 725 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Vista Pump Station 34
Photo 4-17. Failed coating and metal
corrosion on DIP force main in north meter
vault (typical of both vaults).

Photo 4-18. Corrosion stains at copper ground
cable connection and jumper wire at flange
on flow meter (typical of both vaults).

The pipe support saddle in each vault has what ap pears to be a square galvanized steel baseplate bolted to a small concrete mortar pad. Despite th e galvanizing, the edges of the baseplate in each vault show evidence of corrosion (Photo 4-19). Th e corrosion may be due to water standing within the vaults, particularly if it is brackish water.

The plug valve downstream from each flow meter rests on a concrete support. The valve support in the north meter vault exhibits isolated spalling and corrosion of the reinforcing steel, probably due to insufficient depth of concrete cover (Photo 4-20).

Photo 4-19. Corroding baseplate for pipe
support (typical of both vaults).

Photo 4-20. Valve support pedestal in north
meter vault. Corroding reinforcing steel.
05/13/2025 C9 726 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Buena Vista Pump Station 35
The north meter vault drains to the south meter vault, which has a sump pump. The sump pump is connected to the discharge piping by a short length of rubber hose with cam-lock fittings at either end. The lower fitting is severely corroded or encrusted (Photo 4-21), while the upper fitting shows surface corrosion. The fittings appear to be aluminum, which is not corrosion-resistant in an environment with brackish water or seawater. The pump is plugged into a standard 120-volt outlet higher on the vault wall. The outlet box has surface corrosion along its lower edge and may not be watertight (Photo 4-22).

Photo 4-21. Severely corroded or encrusted
quick-connect fitting for sump pump.

Photo 4-22. Surface corrosion at lower edge of
sump pump outlet box in south meter vault.

4.3 Ultrasonic Thickness Measurements
The ultrasonic thickness data is summarized in Tabl e 4-1. As shown in the table, the wall thickness loss for the DIP, at the locations that were tested , was within manufacturing tolerances, except at one location on the header downstream of Pumps 1 and 2. At this location, there appears to be a significant thickness loss of 0.167 inches, or 37% of the assumed nominal thickness. This spool also exhibited localized external corrosion, as noted above in Photo 4-8. The maximum wall thickness loss for the fabricated, rectangular steel suction lines was 9%, which is considered negligible considering the tolerances that may have been applicable (steel pipe made to ASTM standards often has a thickness tolerance of −12.5%).
05/13/2025 C9 727 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Buena Vista Pump Station 36

Table 4-1. Buena Vista Pump Station Ultrasonic Thickness Data Summary LLocation Dia.
(in.)
Measured Thickness (in.) Assumed Pipe
Specifications Max.

Wall
Loss
(in.)
Max.

Wall
Loss
Min. Avg. Max. Class
Nom.

Thick-
ness
(in.)
Cast--
ing
Tol.
(in.)
Pump 1 discharge riser 14 0.399 0.415 0.424 53 0.42 −0.07 0.021 5% Pump 2 discharge riser 14 0.375 0.392 0.408 53 0.42 −0.07 0.045 11% Pump 4 discharge riser 14 0.404 0.409 0.415 53 0.42 −0.07 0.016 4% Pump 5 discharge riser 14 0.402 0.412 0.424 53 0.42 −0.07 0.018 4% Header between Pumps 1 and 2 14 0.390 0.397 0.408 53 0.42 −0.07 0.030 7% Header downstream of Pumps 1 and 2 20 0.283 0.305 0.343 53 0.45 −0.07 0.167 37% Spool upstream of NW. force main penetration 24 0.757 0.758 0.759 (a) (a) (a) (a) (a) Pump 1 suction wall spool (b) 0.343 0.359 0.368 (b) 0.375 (b) 0.032 9% Pump 2 suction wall spool (b) 0.340 0.354 0.371 (b) 0.375 (b) 0.035 9% Pump 4 suction wall spool (b) 0.350 0.367 0.374 (b) 0.375 (b) 0.025 7% Pump 5 suction wall spool (b) 0.351 0.373 0.394 (b) 0.375 (b) 0.024 6% Pump 1 suction reducer (b) 0.517 0.521 0.524 (b) 0.500 (b) (c) (c) Pump 2 suction reducer (b) 0.505 0.520 0.523 (b) 0.500 (b) (c) (c) Pump 4 suction reducer (b) 0.516 0.520 0.523 (b) 0.500 (b) (c) (c) Pump 5 suction reducer (b) 0.515 0.520 0.525 (b) 0.500 (b) (c) (c) Notes
(a) This spool measured much thicker than the published thicknesses for centrifugally cast (typical) ductile iron pipe. It may be p it- cast; the applicable class, nominal thickness, etc., are unknown. (b) The pump suction lines are rectangular and are fabricated from steel. As a result, the pipe “class” is not applicable terminology and they were assumed to have been made from fractional-inch-thickness plate. The plate thickness tolerance is also unknown. (c) Measured thickness within manufacturing tolerances or greater than nominal; wall loss not reported.

4.4 Vibration Analysis Results
Vibration testing was performed on Motors and Pumps 1, 2, 4 and 5. There is no Motor or Pump 3 at the BVPS. The pumps were run at approximatel y 65% and near 100% speed. System control limitations only allowed data to be collected at ap proximately 65% speed on many of the pump test points. General observations of the testing indicate that vibration levels are reasonable on most motor and pump test locations, with the majority meeting ISO and Hydraulic Institute acceptance standards for operating levels. The highest readings were noted in the perpendicular direction on both the motors and the pumps. This appears to be due to a residual resonance issue. There was no indication of high-frequency mechanical or electric al peaks on any of the test points, pointing to minimum hydraulic noise and no apparent VFD issues. Predominant vibration frequency peaks were two, three, and six times running speed, felt primar ily to be the area of re sonant response on these structures. Reed believes the stiffening beams abov e the pumps to be related to reducing vibration.

However, it also appears likely that they were in stalled for seismic considerations. A summary of the testing results is presented in Table 4-2. The full report from Reed Electric is attached in Appendix A.

05/13/2025 C9 728 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Buena Vista Pump Station 37

Table 4-2. Buena Vista Pump Station Vibration Analysis Summary MMotoor OObservation
Motor/Pump 1 Generally comparable or lower levels of vibration compared to the other three pumps that were tested.

Motor/Pump 2 Pump upper bearing has a high 4x peak at 65% speed. Generally higher vibration levels than other pumps.

Motor/Pump 3 Does not exist.

Motor/Pump 4 Showed unusual running speed harmonics on the motor upper bearing. Generally had the highest readings at all test points.

Motor/Pump 5
Motor has high 6x peak on motor upper bearings, with some high-frequency peaks indicative of bearing looseness. Pump upper bearing shows some indication of cavitation noise at low load and is the only pump at the station to exhibit this.

4.5 Conclusions
Based on the results of the condition assessment, V&A presents the following conclusions:

1. In general, the concrete interior surfaces of the dry well were in good condition (VANDA Level 1). There were, however, some isolated areas of groundwater infiltration, some with staining indicating possible corrosion of the reinforcing steel. The grout pads under the pump bases showed deterioration at the edges in some cases.

2. The coating on the piping was generally in go od condition at higher elevations, with numerous chips and other defects in the coating at lower elevations. Generally, there was minor surface corrosion where the coating was damaged. There was also one spool downstream of Pumps 1 and 2 that exhibited moderate external corrosion.

3. At most of the ultrasonic thickness testing location s, the dry well piping is in good condition, but there was one location on the header downstream of Pumps 1 and 2 that exhibited a significant thickness loss of 37%. This location also exhibited external corrosion. It is possible, though considered unlikely, that the pipe at this location was manufactured thinner than required by AWWA standards. No signific ant exterior corrosion or leaks were observed on the rest of the piping in the dry well, which was outside the ultrasonic testing areas.

4. The bathroom drain piping and ventilation ducting exhibited various moderate-severity defects.

5. The meter vaults show moderate to extensive groundwater infiltration, with staining that indicates possible corrosion of the reinforcing steel. The vaults are only a few years old. The extent of staining may indicate that the water leaking into the vaults is brackish, which would promote corrosion.

6. The piping, pipe supports, sump pump fittings, and electrical items within the meter vaults also showed various defects that appear to be related to the grou ndwater infiltration, particularly if it is brackish.

7. Reed Electric identified several minor- to moderate-severity vibration issues and recommended that these be addressed during the next planned outage. 05/13/2025 C9 729 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Buena Vista Pump Station 38

4.6 Recommendations
Based on the conclusions of the condition assessment, V&A presents the following recommendations:

1. Monitor areas of infiltration within the dry we ll for increased evidence of infiltration or corrosion staining. Consider further evaluation of the concrete and reinforcing steel in areas where there is corrosion staining. Testing to be considered includes:
o Concrete core analysis to identify corrosion stimulants and concrete characteristics o Determining placement of reinforcing steel
o Identify corrosion potential on reinforcing steel and visually verify condition

2. Consider repairing the grout pads under the pump bases.

3. Recoat the exterior of the piping, at least at lower elevations, to prevent further corrosion.

The lower elevations are subject to more water splashing and dripping from operations and maintenance activities, which exacerbates any minor coating defects that may be present.

Prepare surfaces to remain per SSPC SP 2 to 3. Coat with a 100% solids epoxy or polyurethane coating system, such as Carbol ine Carboguard 890, PPG Amercoat Amerlock 400, or Tnemec Series N69 at 2 to 3 mils dry film thickness.

4. Calculate the minimum required thickness for the piping based on pressure, loading, etc.

Compare the minimum required thickness against the measured thicknesses in this report to determine the amount of further wall loss that can be tolerated, if any, before the integrity of the piping is impaired. With the results of th is analysis in mind, consider conducting the following activities to address corrosion and integrity of the dry well piping:
o Address the corrosion on the spool downs tream of Pumps 1 and 2. Replacing the spool is probably the most cost-effective option. When the piping is shut down and drained for this activity, consider using this opportunity to evaluate the interior of the remaining piping. This could be done using closed-circuit television (CCTV). This would provide further insight on the lining condition and corrosion inside the piping, which is expected to be localized.
o Ensure that there is a contingency plan and materials available in case of a piping leak or failure. The data indicated that there may be isolated areas of corrosion.

Consider the impact of a failure or leak. If the impact to operations is greater, the preparations should be more comprehensive, and further evaluation of the piping should be conducted.

5. Repair the bathroom drain piping and ventilation ducting connections.

6. Perform testing to quantify the extent of degr adation of the concrete and reinforcement in the two meter vaults. Testing to consider is similar to that recommended for the dry well.

Sample the water entering the vaults for resistivity and chloride content.

7. Address the electrical connections within the meter vaults (meter ground cables and power for sump pump). Replace corroded connectors with corrosion-resistant materials and take precautions for galvanic corrosion between dissimilar metals.

8. Replace the cam-lock fittings for the sump pump in the south meter vault. 05/13/2025 C9 730 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Buena Vista Pump Station 39

9. Assuming that the groundwater entering the meter vaults is brackish (see sampling recommendation above), use materials and coat ings suitable for a marine environment for all items within the vaults.

10. Consider whether the groundwater may also be aggressive to the buried DIP force mains within the pump station site, review the construction details for the force mains to determine whether adequate corrosion protection was provided for the buried pipe. Consider conducting field evaluations to determine the co rrosivity of the soil and/or the condition of the buried DIP.

11. Reed Electric recommended the following actions for the pumps and motors based on the vibration analysis results:
o The evidence of historical vibration issues based on the need for dampeners on all motor and pump structures necessitates the frequent periodic monitoring of the vibration, to assure that the stiffness of the arms does not change significantly with time or maintenance.
o #4 Motor – If a motor inspection is forecast , this would be the prioritized unit for mechanical disassembly and inspection.
o #5 Motor & Pump – If a unit inspection is fo recast, this would be the prioritized unit for motor bearing inspection and pump impeller inspection. o #2 Pump – The pump dampener structures and piping supports should be inspected for rigidity.

05/13/2025 C9 731 of 1078
V&A Project No. 15-0024 Raceway Pump Station 40

5.0 RACEWAY PUMP STATION
The RPS was constructed circa 1988 and is a 1.9 mgd pump station. The station was replaced in 2007. V&A conducted a visual assessment and ultraso nic thickness testing at the pump station on September 11, 2015. The findings of these studies are presented below.

5.1 Visual Assessment
The majority of exterior surface of pump piping ha s no signs of corrosion. The exterior coating is in good condition. There is corrosion staining and cr acked coating on conduits near the pump piping.

The concrete reservoir has cracking and staining in dicating possible infiltration or exfiltration at some of those areas. The concrete at the guard rail connections is cracked and damaged by spalling.

The embedded guardrail post was not coated with a coal tar and PVC sleeve in order to isolate it from the concrete. There is no horizontal reinforcing steel on the outer wall of the curb which also allowed the corroding railing to cr ack the concrete. Examples of the defects are shown in Photo 5-1 through Photo 5-6.

Photo 5-1. Cracking and staining in
concrete reservoir.

Photo 5-2. Crack in concrete at base of
guard rail.
05/13/2025 C9 732 of 1078
City of Vista, California
Pump Station Condition Assessments Draft Report
V&A Project No. 15-0024 Raceway Pump Station 41
Photo 5-3. Defective coating, staining, cracks,
missing concrete at electrical box support.

Photo 5-4. Defective coating and corrosion on
flange near Pump 3 discharge piping.

Photo 5-5. Spalling at base of guard rail. P hoto 5-6. Staining on electrical box.

5.2 Ultrasonic Thickness Measurements
The ultrasonic thickness data is summarized in Tabl e 5-1. As shown in the table, the wall thickness loss for the DIP and fittings, at the locations that were tested, was mostly within manufacturing tolerances. At three locations the wall thickness was outside the tolerances by what is considered a minor degree. The maximum wall thickness loss was calculated to be 18% for the DIP and 21% for the fittings. However, at these locations, the wall thickness was outside the manufacturing tolerances by only 0.028 inches or less.
05/13/2025 C9 733 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Raceway Pump Station 42

Table 5-1. Raceway Pump Station Ultrasonic Thickness Data Summary LLocation

Dia.
(in.)
Measured Thickness (in.) Assumed Pipe
Specifications Max.

Wall
Loss
(in.)
Max.

Wall
Loss
Min. Avg. Max. Class
Nom.

Thick-
ness
(in.)
Cast--
ing
Tol.
(in.)
Pump 1 discharge, ground penetration 6 0.352 0.412 0.435 56 0.43 −0.05 0.078 18% Pump 2 discharge, ground penetration 6 0.359 0.381 0.397 55 0.40 −0.05 0.041 10% Pump 3 discharge, ground penetration 6 0.303 0.341 0.361 54 0.37 −0.05 0.067 18% Pump 1 discharge, horizontal spool 6 0.353 0.361 0.366 54 0.37 −0.05 0.017 5% Pump 2 discharge, horizontal spool 6 0.378 0.383 0.392 55 0.40 −0.05 0.022 6% Pump 3 discharge, horizontal spool 6 0.363 0.374 0.396 55 0.40 −0.05 0.037 9% Pump 1 discharge, elbow 6 0.435 0.501 0.547 250 0.55 −0.10 0.115 21% Pump 2 discharge, elbow 6 0.456 0.516 0.639 250 0.55 −0.10 0.094 17% Pump 3 discharge, elbow 6 0.455 0.515 0.592 250 0.55 −0.10 0.095 17% Discharge header, horizontal spool 8 0.357 0.376 0.399 54 0.39 −0.05 0.033 8% Discharge header, ground penetration 8 0.353 0.366 0.379 54 0.39 −0.05 0.037 9% Discharge header, elbow 8 0.653 0.702 0.759 250 0.60 −0.12 (a) (a) Notes
(a) Measured thickness within manufacturing tolerances or greater than nominal; wall loss not reported.

5.3 Conclusions
Based on the results of the condition assessment, V&A presents the following conclusions:

1. There is potential infiltration/exfiltration at cr acks in the concrete reservoir. The concrete surface is in good condition though (VANDA Level 1). The concrete has spalled at the base of the guardrail around the concrete reservoir due to a lack of insulation between the aluminum and concrete material.

2. The coating on the electrical box supports has failed and the concrete is damaged at the base. There is corrosion staining on the electrical box and conduits.

3. The surface of the piping is in good condition, with the majority of the coating (about 90%) intact. The coating on the flange near the Pump 3 discharge pipe has failed though, leading to the exposed metal surface to have moderate corrosion (VANDA Level 3).

4. At most of the testing locations, the pipe and fittings are in good condition. There were a few locations that showed wall thickness outsid e the manufacturing tolerances by what is considered a minor degree. The pipe spools that showed this increased wall thickness loss were assumed to have been manufactured th icker than Class 53 (minimum required for flanged DIP per AWWA C115). Overall, while there may have been a minor thickness loss at a few locations, it does not appear to have been to a significant degree. The piping and fittings are rated a VANDA Level 1.

05/13/2025 C9 734 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Raceway Pump Station 43

5.4 Recommendations
Based on the conclusions of the condition assessment, V&A presents the following recommendations:

1. Seal points of infiltration/exfiltration within the concrete reservoir

2. Install a grout or sealant at the base of the aluminum posts and slope it so that water runoff is allowed to flow away from the embedded section.

3. Replace corroded conduits.

4. Recoat or replace the corroded metal flange near the Pump 3 discharge pipe.

5. Recoat piping and electrical equipment as ne eded. Prepare surfaces to remain per SSPC SP 2 to 3. Coat with a 100% solids epoxy or po lyurethane coating system, such as Carboline Carboguard 890, PPG Amercoat Amerlock 400, or Tnemec Series N69 at 2 to 3 mils dry film thickness.

05/13/2025 C9 735 of 1078
05/13/2025 C9 736 of 1078

V&A Project No. 15-0024 Appendix A. Reed Electric & Field Services Vibration Analysis Report A-1

APPENDIX A. REED ELECTRIC & FIELD

SERVICES VIBRATION ANALYSIS REPORT

As mentioned in Section 3.3 and 4.4, attached are the results of the vibration analysis for the BCPS and the BVPS.

05/13/2025 C9 737 of 1078
05/13/2025 C9 738 of 1078

1 BUENA CREEK SEWAGE PUMPS VIBRATION ANALYSIS

FOR CONDITION ASSESSMENT

TEST SETUP:

1. Instrumentation: An ADASH 4-channel data recorder and analyzer was utilized along with three magnetic- mount accelerometers and a laser speed tachometer (see typical Motor monitoring setup, Figure 1).

2. Test Locations: The sensors were mounted on the Motor Upper, Motor Lower, Pump Upper, and Pump Lower bearings, in the Inline, Crossline (Perpendicular), and axial directions for each of the tests (see test layout schematic, Figure 2).

3. Test Conditions: The units were run between 78-87% load under normal operating mode. System control limitations and high cavitation vibration at lower loads dictated that data only be collected at that condition. The following data was recorded for each test:
a. overall velocity and displacement vibration
b. velocity spectrum plots
c. filtered amplitude/phase measurements (where the tach was available) See a table of overall velocity levels for each test point in Figure 6, and charts showing comparative levels on Pages 11 -14.

OBSERVATIONS:

4. General:
a. Vibration levels are high on most motor and pump test locations, with many exceeding ISO and Hydraulic Institute acceptance standards for operating levels. b. In general, the high readings were very directional, primarily in the In-Line (Parallel) direction on both the Motors and Pumps. The highest readings on each pump system were typically in the Pump Lower bearing area. This was felt to be due to a residual system resonance issue, which appears to be sensitive to piping support stiffness (see and typical motor-pump layout, Figure 3). c. In general, there was no indication of high-frequency mechanical or electrical peaks on any of the test points, pointing to minimum hydraulic noise, and no apparent VFD issues. d. Predominant frequencies peaks of vibration was 2X running speed, felt primarily to be the area of resonant response on these structures.

5. Specific Units:
a. #1 Motor-Pump – This unit showed high directional levels in the inline direction from the motor bearings down to the pump bearings. The predominant frequency of vibration was the 2X running speed peak (see all #1 bearing inline spectrums Figure 7). This motor generally had the highest readings at all test points (see level comparison charts, Pages 11– 14). b. #2 Motor-Pump – This unit showed similar high directional levels in the inline direction from the motor bearings down to the pump bearings, though at lower levels, with the same predominant frequency (see all #2 bearing inline spectrums Figure 8, and level comparison charts, Pages 11– 14). c. #4 Pump – the pump bearings showed a higher perpendicular relationship than the other pumps. 05/13/2025 C9 739 of 1078

2 RECOMMENDATIONS:

1. #3 Motor & Pump: This unit had VFD drive or other electrical issues during the test. It will need to be scheduled for a retest when feasible.

2. General Monitoring: The evidence of high vibration on all motor and pump structures warrants a full structural mode shape analysis, to allow proper definition of any resonance issues as they relate to structure, and should result in effective recommendations to adjust or change the supports, etc., to reduce the effect.

3. #1 Motor & Pump – The extremely high levels on this unit warrant prioritized scheduling of detailed analysis and correction. In the meantime, the stiffness of the pump supports should be inspected for rigidity (see typical pump supports, Figures 4 & 5).

4. #2 Motor & Pump – The high levels on this unit warrant scheduling of detailed analysis and correction. In the meantime, the stiffness of the pump supports should be inspected for rigidity.

5. #4 Pump – This units’ suction piping support was found loose, and should be adjusted.

DATA

1. A summary table of overall velocity levels for each position at each test load is shown in Figure 6.

2. Charts showing comparison levels for each position at the different loads is shown on Pages 11 - 14.

3. Spectrum Waterfall plots for each position are available if requested.

05/13/2025 C9 740 of 1078

3 Figure 1 - Typical Buena Creek Motor Bearing Monitoring Points 05/13/2025 C9 741 of 1078

4 Figure 2 - Typical Pump Layout Test Locations
05/13/2025 C9 742 of 1078

5 Figure 3 – Buena Creek Motor-Pumps

05/13/2025 C9 743 of 1078

6 Figure 4 - Pump #4 suction piping saddle support

05/13/2025 C9 744 of 1078

7 Figure 5 - Pump #5 discharge piping support

05/13/2025 C9 745 of 1078

8 Plant:

Buena Creek
Plant Instrument:

ADASH
VA4 PRO

Unit:

Pumps 1,2, 3,
4, and 5 Operator: Costa Yiannakakis
Date: 9/10/2015
Overall Spectrum IPS, RMS (0-1600 Hz)
Bearing Probe Dir. % Load Speed (RPM) Pump #1 Pump #2 Pump #3 Pump #4 Pump #5 Motor Upper Inline 87 1560 3.736 1.508 Not Op. 1.140 1.037 Motor Upper Perpendicular 87 1560 0.215 0.206 Not Op. 0.295 0.096 Motor Upper Axial 87 1560 0.186 0.090 Not Op. 0.268 0.133 Motor Lower Inline 87 1560 2.527 1.503 Not Op. 1.220 0.753 Motor Lower Perpendicular 87 1560 0.135 0.116 Not Op. 0.293 0.085 Pump Upper Inline 87 1560 3.796 3.251 Not Op. 1.897 1.278 Pump Upper Perpendicular 87 1560 0.197 0.241 Not Op. 0.437 0.114 Pump Upper Axial 87 1560 0.304 0.184 Not Op. 0.184 0.069 Pump Lower Inline 87 1560 4.081 3.442 Not Op. 1.388 1.516 Pump Lower Perpendicular 87 1560 0.203 0.351 Not Op. 0.418 0.124

Figure 6 - Buena Creek Pumps - Overall Velocity Levels for all positions for each test point

05/13/2025 C9 746 of 1078

9 Figure 7 - Buena Creek Pump #1 Motor & Pump Bearings Inline Spectrums

05/13/2025 C9 747 of 1078

10 Figure 8 - Buena Creek Pump #2 Motor & Pump Bearings Inline Spectrums

05/13/2025 C9 748 of 1078

11 0.000

0.500

1.000

1.500

2.000

2.500

3.000

3.500

4.000
Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Velocity, IPS
Buena Creek Pumps
Motor Upper Inline - at 85% Load

0.000

0.050

0.100

0.150

0.200

0.250

0.300

0.350
Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Velocity, IPS
Buena Creek Pumps
Motor Upper Perpendicular - at 85% Load

0.000

0.050

0.100

0.150

0.200

0.250

0.300
Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Velocity, IPS
Buena Creek Pumps
Motor Upper Axial - at 85% Load
05/13/2025 C9 749 of 1078

12 0.000

0.500

1.000

1.500

2.000

2.500

3.000
Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Velocity, IPS
Buena Creek Pumps
Motor Lower Inline - at 85% Load

0.000

0.050

0.100

0.150

0.200

0.250

0.300

0.350
Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Velocity, IPS
Buena Creek Pumps
Motor Lower Perpendicular- at 85% Load
05/13/2025 C9 750 of 1078

13 0.000

0.500

1.000

1.500

2.000

2.500

3.000

3.500

4.000
Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Velocity, IPS
Buena Creek Pumps
Pump Upper Inline - at 85% Load

0.000

0.050

0.100

0.150

0.200

0.250

0.300

0.350

0.400

0.450

0.500
Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Velocity, IPS
Buena Creek Pumps
Pump Upper Perpendicular- at 85% Load
0 0.05

0.1 0.15

0.2 0.25

0.3 0.35
Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Velocity, IPS
Buena Creek Pumps
Pump Upper Axial - at 85% Load
05/13/2025 C9 751 of 1078

14 0

0.5 1

1.5 2

2.5 3

3.5 4

4.5 Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Velocity, IPS
Buena Creek Pumps
Pump Lower Inline - at 85% Load
0 0.05

0.1 0.15

0.2 0.25

0.3 0.35

0.4 0.45
Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Velocity, IPS
Buena Creek Pumps
Pump Lower Perpendicular - at 85% Load
05/13/2025 C9 752 of 1078

1 BUENA VISTA & SEWAGE PUMPS VIBRATION ANALYSIS

FOR CONDITION ASSESSMENT

TEST SETUP:

1. Instrumentation: An ADASH 4-channel data recorder and analyzer was utilized along with three magnetic- mount accelerometers and a laser speed tachometer (see typical Pump monitoring setup, Figure 1).

2. Test Locations: The sensors were mounted on the Motor Upper, Motor Lower, Pump Upper, and Pump Lower bearings, in the Inline, Crossline (Perpendicular), and axial directions for each of the tests (see test layout schematic, Figure 2).

3. Test Conditions: The units were run at ~65% and near 100% load. System control limitations only allowed data to be collected at ~65% load on many of the pump test points. The following data was recorded for each test:
a. overall velocity and displacement vibration
b. velocity spectrum plots
c. filtered amplitude/phase measurements (where the tach was available) See a table of overall velocity levels for each test point in Figure 5, and charts showing comparative levels on Pages 12 – 15.

OBSERVATIONS:

4. General:
a. Vibration levels are reasonable on most motor and pump test locations, with the majority meeting ISO and Hydraulic Institute acceptance standards for operating levels. b. In general, the highest readings were noted in the Cross Line (Perpendicular) direction on both the Motors and Pumps. This was felt to be due to a residual system resonance issue, which was likely the reason for the stiffening beams on both the Motor and Pump structures (see and typical motor and pump layouts, 3 & 4).
c. In general, there was no indication of high-frequency mechanical or electrical peaks on any of the test points, pointing to minimum hydraulic noise, and no apparent VFD issues. d. Predominant frequencies peaks of vibration were 2X, 3X, and 6X running speed, felt primarily to be the area of resonant response on these structures.

5. Specific Units:
a. #4 Motor – This motor showed some unusual multiple harmonics of running speed on the Motor Upper bearing (see Motor Upper Perpendicular spectrum Figure 6). This motor generally had the highest readings at all test points (see level comparison charts, Pages 12 – 15). b. #5 Motor & Pump – This motor has a high 6X peak on the Motor Upper bearings, with some high- frequency peaks indicative of bearing looseness (see Motor Upper Perpendicular spectrum Figure 7).

Additionally, the Pump Upper bearing shows some indication of cavitation noise, and is the only pump in the plant to exhibit this, though only at low load (see Pump Upper Perpendicular spectrum, Figure 8). c. #2 Pump – the pump Upper bearing has a high 4X peak at 65% load. Most of this pump’s test points are higher than the other pumps (see Pump Perpendicular spectrum, Figure 9). 05/13/2025 C9 753 of 1078

2 RECOMMENDATIONS:

1. General Monitoring: The evidence of historical vibration issues based on the need for dampeners on all motor and pump structures necessitates the frequent periodic monitoring of the vibration, to assure that the stiffness of the arms does not change significantly with time or maintenance.

2. #4 Motor – If a motor inspection is forecast, this would be the prioritized unit for mechanical disassembly and inspection.

3. #5 Motor & Pump – If a unit inspection is forecast, this would be the prioritized unit for motor bearing inspection and pump impeller inspection.

4. #2 Pump – The pump dampener structures and piping supports should be inspected for rigidity.

DATA

1. A summary table of overall velocity levels for each position at each test load is shown in Figure 5.

2. Charts showing comparison levels for each position at the different loads is shown on Pages 12 - 15.

3. Spectrum Waterfall plots for each position are available if requested.

Figure 1 - Typical Buena Vista Pump Upper Bearing Monitoring Points 05/13/2025 C9 754 of 1078

3 Figure 2 - Typical Pump Layout Test Locations
05/13/2025 C9 755 of 1078

4 Figure 3 – Buena Vista Motors

05/13/2025 C9 756 of 1078

5 Figure 4 - Buena Vista Pump

05/13/2025 C9 757 of 1078

6 Plant: Buena Vista
Plant
Instrument: ADASH VA4 PRO

Unit: Pumps 1,2,
4, and 5
Operator: Costa Yiannakakis

Date: 9/10/2015
Overall Spectrum IPS, RMS (0-1600 Hz)
Bearing Probe Dir.

Unit
Load (%)
Speed
(RPM) Pump #1 Pump #2 Pump #3 Pump #4 Pump #5
Motor Upper Inline 65 780 0.015 0.070 N/A 0.033 0.036
95 1185 0.117 0.050 N/A 0.213 0.123
Motor Upper Perp. 65 780 0.112 0.297 N/A 0.151 0.249
95 1185 0.361 0.483 N/A 0.801 0.731
Motor Upper Axial 65 780 0.016 0.027 N/A 0.024 0.026
95 1185 0.060 0.039 N/A 0.114 0.048
Motor Lower Inline 65 780 0.017 0.042 N/A 0.036 0.067
95 1185 0.096 --- N/A 0.078 ---
Motor Lower Perp. 65 780 0.081 0.357 N/A 0.155 0.335
95 1185 0.309 --- N/A 0.558 ---
Pump Upper Inline 65 780 0.058 0.156 N/A 0.075 0.128
95 1185 --- --- N/A --- ---
Pump Upper Perp. 65 780 0.259 0.872 N/A 0.226 0.676
95 1185 --- --- N/A --- ---
Pump Upper Axial 65 780 0.06 0.082 N/A 0.067 0.094
95 1185 --- --- N/A --- ---
Pump Lower Inline 65 780 0.127 0.115 N/A 0.058 0.123
95 1185 --- --- N/A --- ---
Pump Lower Perp. 65 780 0.512 0.557 N/A 0.202 0.488
95 1185 --- --- N/A --- ---

Figure 5 - Buena Vista Pumps - Overall Velocity Levels for all positions for each test point 05/13/2025 C9 758 of 1078

7 Figure 6 - Buena Vista Pump #4 Motor Upper Perpendicular Spectrum

05/13/2025 C9 759 of 1078

8 Figure 7 - Buena Vista Pump #5 Motor Upper Perpendicular Spectrum 05/13/2025 C9 760 of 1078

9 Figure 8 - Buena Vista Pump #5 Pump Upper Perpendicular 05/13/2025 C9 761 of 1078

10 Figure 9 - Buena Vista Pump #2 Pump Upper Perpendicular Spectrum

05/13/2025 C9 762 of 1078

11 0.000

0.100

0.200

0.300

0.400

0.500

0.600

0.700

0.800

0.900
Pump #1 Pump #2 Pump #4 Pump #5
IPS, Velocity
Buena Vista Pumps
Motor Upper Perpendicular
65% Load 98% Load
05/13/2025 C9 763 of 1078

12 0.000

0.020

0.040

0.060

0.080

0.100

0.120
Pump #1 Pump #2 Pump #4 Pump #5
IPS, Velocity
Buena Vista Pumps
Motor Lower Inline
65% Load 98% Load
05/13/2025 C9 764 of 1078

13 0

0.02 0.04

0.06 0.08

0.1 Pump #1 Pump #2 Pump #4 Pump #5
IPS, Velocity
Buena Vista Pumps
Pump Upper Axial
65% Load 98% Load
05/13/2025 C9 765 of 1078

14 0

0.02 0.04

0.06 0.08

0.1 0.12

0.14 Pump #1 Pump #2 Pump #4 Pump #5
IPS, Velocity
Buena Vista Pumps
Pump Lower Inline
65% Load 98% Load
0 0.1

0.2 0.3

0.4 0.5

0.6 Pump #1 Pump #2 Pump #4 Pump #5
IPS, Velocity
Buena Vista Pumps
Pump Lower Perpendicular
65% Load 98% Load
05/13/2025 C9 766 of 1078

V&A Project No. 15-0024 Appendix B. In-Situ Soil Resistivity Complete Results B-1

APPENDIX B. IN-SITU SOIL RESISTIVITY

COMPLETE RESULTS

As mentioned in Section 3.4, the results of the in -situ soil resistivity test ing using the Wenner Four- Electrode Method are presented in Table A-1.

Table A- 1. In-situ Soil Resistivity Results
SSite
Number
Depth
(feet)
Resistance
to Depth,
Meter
Reading
(ohm)
Resistivity
to Depth
(ohm-cm)
Layer
(feet)
Resistance
of Soil
Layer
(ohm)
Resistivity
of Soil
Layer
(ohm-cm)
Degree of
Corrosivity
for Layer
1 5 5.72 5,477 0 - 5 5.7 5,477 Mild

7.5 2.62 3,763 5 - 7.5 4.8 2,315 Mild
10 1.24 2,375 7.5 - 10 2.4 1,127 Moderate
15 0.66 1,896 10 - 15 1.4 1,351 Moderate
20 0.39 1,494 15 - 20 1.0 913 High
2 5 15.66 14,995 0 - 5 15.7 14,995 Negligible

7.5 8.05 11,563 5 - 7.5 16.6 7,931 Mild
10 5.33 10,208 7.5 - 10 15.8 7,552 Mild
15 2.33 6,693 10 - 15 4.1 3,964 Mild
20 1.26 4,826 15 - 20 2.7 2,627 Mild
3 5 9.15 8,762 0 - 5 9.2 8,762 Mild

7.5 6.41 9,207 5 - 7.5 21.4 10,249 Negligible
10 5.29 10,131 7.5 - 10 30.3 14,495 Negligible
15 3.10 8,905 10 - 15 7.5 7,170 Mild
20 2.15 8,235 15 - 20 7.0 6,718 Mild
4 5 4.52 4,328 0 - 5 4.5 4,328 Mild

7.5 3.19 4,582 5 - 7.5 10.8 5,191 Mild
10 2.21 4,232 7.5 - 10 7.2 3,444 Mild
15 1.30 3,734 10 - 15 3.2 3,023 Mild
20 1.15 4,405 15 - 20 10.0 9,544 Mild
5 5 6.25 5,985 0 - 5 6.3 5,985 Mild
05/13/2025 C9 767 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Appendix B. In-Situ Soil Resistivity Complete Results B-2

SSite
Number
Depth
(feet)
Resistance
to Depth,
Meter
Reading
(ohm)
Resistivity
to Depth
(ohm-cm)
Layer
(feet)
Resistance
of Soil
Layer
(ohm)
Resistivity
of Soil
Layer
(ohm-cm)
Degree of
Corrosivity
for Layer

7.5 4.57 6,564 5 - 7.5 17.0 8,140 Mild
10 3.99 7,641 7.5 - 10 31.4 15,052 Negligible
15 2.45 7,038 10 - 15 6.3 6,078 Mild
20 0.76 2,911 15 - 20 1.1 1,055 Moderate
6 5 2.83 2,710 0 - 5 2.8 2,710 Mild

7.5 2.06 2,959 5 - 7.5 7.6 3,625 Mild
10 1.54 2,949 7.5 - 10 6.1 2,921 Mild
15 1.15 3,304 10 - 15 4.5 4,348 Mild
20 0.89 3,409 15 - 20 3.9 3,769 Mild
7 5 1.67 1,599 0 - 5 1.7 1,599 Moderate

7.5 0.88 1,264 5 - 7.5 1.9 891 High
10 0.60 1,149 7.5 - 10 1.9 903 High
15 0.44 1,264 10 - 15 1.7 1,580 Moderate
20 0.24 919 15 - 20 0.5 506 High
8 5 2.29 2,193 0 - 5 2.3 2,193 Mild

7.5 1.08 1,551 5 - 7.5 2.0 979 High
10 0.73 1,398 7.5 - 10 2.3 1,078 Moderate
15 0.41 1,178 10 - 15 0.9 896 High
20 0.24 919 15 - 20 0.6 554 High
9 5 1.37 1,312 0 - 5 1.4 1,312 Moderate

7.5 0.87 1,250 5 - 7.5 2.4 1,141 Moderate
10 0.61 1,168 7.5 - 10 2.0 977 High
15 0.21 603 10 - 15 0.3 307 Very High
20 0.16 613 15 - 20 0.7 643 High
10 5 0.78 747 0 - 5 0.8 747 High

7.5 0.36 517 5 - 7.5 0.7 320 Very High
10 0.22 421 7.5 - 10 0.6 271 Very High
15 0.16 460 10 - 15 0.6 562 High
20 0.11 421 15 - 20 0.4 337 Very High
11 5 3.40 3,256 0 - 5 3.4 3,256 Mild

7.5 2.27 3,260 5 - 7.5 6.8 3,270 Mild
10 1.74 3,332 7.5 - 10 7.5 3,568 Mild
05/13/2025 C9 768 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Appendix B. In-Situ Soil Resistivity Complete Results B-3

SSite
Number
Depth
(feet)
Resistance
to Depth,
Meter
Reading
(ohm)
Resistivity
to Depth
(ohm-cm)
Layer
(feet)
Resistance
of Soil
Layer
(ohm)
Resistivity
of Soil
Layer
(ohm-cm)
Degree of
Corrosivity
for Layer
15 0.93 2,672 10 - 15 2.0 1,913 Moderate
20 0.60 2,298 15 - 20 1.7 1,619 Moderate
12 5 0.82 785 0 - 5 0.8 785 High

7.5 0.48 689 5 - 7.5 1.2 554 High
10 0.32 613 7.5 - 10 1.0 460 Very High
15 0.18 517 10 - 15 0.4 394 Very High
20 0.14 536 15 - 20 0.6 603 High
13 5 3.67 3,514 0 - 5 3.7 3,514 Mild

7.5 2.49 3,576 5 - 7.5 7.7 3,708 Mild
10 1.76 3,371 7.5 - 10 6.0 2,874 Mild
15 1.26 3,620 10 - 15 4.4 4,247 Mild
20 1.14 4,366 15 - 20 12.0 11,462 Negligible
14 5 0.41 393 0 - 5 0.4 393 Very High

7.5 0.20 287 5 - 7.5 0.4 187 Very High
10 0.15 287 7.5 - 10 0.6 287 Very High
15 0.09 259 10 - 15 0.2 215 Very High
20 0.07 268 15 - 20 0.3 302 Very High
15 5 0.60 575 0 - 5 0.6 575 High

7.5 0.35 503 5 - 7.5 0.8 402 Very High
10 0.30 575 7.5 - 10 2.1 1,005 Moderate
15 0.18 517 10 - 15 0.5 431 Very High
20 0.13 498 15 - 20 0.5 448 Very High
16 5 0.86 823 0 - 5 0.9 823 High

7.5 0.63 905 5 - 7.5 2.4 1,128 Moderate
10 0.48 919 7.5 - 10 2.0 965 High
15 0.31 891 10 - 15 0.9 838 High
20 0.24 919 15 - 20 1.1 1,018 Moderate
17 5 0.83 795 0 - 5 0.8 795 High

7.5 0.51 733 5 - 7.5 1.3 633 High
10 0.41 785 7.5 - 10 2.1 1,001 Moderate
15 0.23 661 10 - 15 0.5 502 High
20 0.16 613 15 - 20 0.5 503 High
05/13/2025 C9 769 of 1078

City of Vista, California
Pump Station Condition Assessments Draft Report

V&A Project No. 15-0024 Appendix B. In-Situ Soil Resistivity Complete Results B-4

SSite
Number
Depth
(feet)
Resistance
to Depth,
Meter
Reading
(ohm)
Resistivity
to Depth
(ohm-cm)
Layer
(feet)
Resistance
of Soil
Layer
(ohm)
Resistivity
of Soil
Layer
(ohm-cm)
Degree of
Corrosivity
for Layer
18 5 0.42 402 0 - 5 0.4 402 Very High

7.5 0.29 417 5 - 7.5 0.9 449 Very High
10 0.24 460 7.5 - 10 1.4 666 High
15 0.15 431 10 - 15 0.4 383 Very High
20 0.11 421 15 - 20 0.4 395 Very High
19 5 1.38 1,321 0 - 5 1.4 1,321 Moderate

7.5 1.01 1,451 5 - 7.5 3.8 1,804 Moderate
10 0.85 1,628 7.5 - 10 5.4 2,569 Mild
15 0.36 1,034 10 - 15 0.6 598 High
20 0.22 843 15 - 20 0.6 542 High
20 5 0.35 335 0 - 5 0.4 335 Very High

7.5 0.20 287 5 - 7.5 0.5 223 Very High
10 0.15 287 7.5 - 10 0.6 287 Very High
15 0.12 345 10 - 15 0.6 575 High
20 0.08 306 15 - 20 0.2 230 Very High

05/13/2025 C9 770 of 1078

V&A Project No. 15-0024 Appendix C. Project X Corrosion Engineering Soil Analysis Report C-1

APPENDIX C. PROJECT X CORROSION

ENGINEERING SOIL ANALYSIS REPORT

As mentioned in Section 3.5, attached are the results of the soil sample analysis for the BCPS.

05/13/2025 C9 771 of 1078
05/13/2025 C9 772 of 1078
Project X REPORT S160216A
Corrosion Engineers Page 1
Soil & Condition Assessment – Corrosion Engineering
29970 Technology Dr, Suite 105F, Murrieta, CA 92563 Tel: 213-928-7213 Fax: 951-226-1720 www.projectxcorrosion.com
City of Vista Rehab
February 22, 2016
PREPARED FOR:

MICHAEL SHERMAN

V&A ENGINEERING
11011 VIA FRONTERA SUITE C
SAN DIEGO, CA 92127
[email protected]
Client Job Number: 15-0024
Project X Job Number: S160216A
05/13/2025 C9 773 of 1078
Project X REPORT S160216A
Corrosion Engineers Page 2
Soil & Condition Assessment – Corrosion Engineering
29970 Technology Dr, Suite 105F, Murrieta, CA 92563 Tel: 213-928-7213 Fax: 951-226-1720 www.projectxcorrosion.com

SOIL ANALYSIS LAB RESULTS
Client: V&A Engineering
Job Name: City of Vista Rehab
Client Job Number: 15-0024
Project X Job Number: S160216A
February 22, 2016
Unk = Unknown
NT = Not Tested
ND = Not Detected
mg/kg = milligrams per kilogram (parts per million) of dry soil weight mg/L - milligrams per liter of liquid volume
Chemical Analysis performed on 1:3 Soil-To-Water extract Please call if you have any questions.

Respectfully Submitted,
Eddie Hernandez, M.Sc., P.E.

Sr. Corrosion Consultant
NACE Corrosion Technologist #16592
Professional Engineer
California No. M37102
[email protected]
specececccce tftfttftftftfulululululullullylylyllylyy SSSSSSSSSSSuububububuububbuubuu mimimittttttttttedeee ,

05/13/2025 C9 774 of 1078
PUMP STATION REHABILITATION STUDY | CITY OF VISTA
FINAL | AUGUST ͮͬͭͲ
Appendix F
FLOW SCIENCE INCORPORATED: BUENA CREEK

LIFT STATION AND FORCE MAIN POTENTIAL

PRESSURE SURGE ISSUES AND MITIGATION

AL TERNATIVES TECHNICAL MEMO
05/13/2025 C9 775 of 1078
05/13/2025 C9 776 of 1078
05/13/2025 C9 777 of 1078
05/13/2025 C9 778 of 1078
05/13/2025 C9 779 of 1078
05/13/2025 C9 780 of 1078
05/13/2025 C9 781 of 1078
05/13/2025 C9 782 of 1078
PUMP STATION REHABILITATION STUDY | CITY OF VISTA
FINAL | AUGUST ͮͬͭͲ
Appendix G
BUENA VISTA PUMP STATION: COST ESTIMATE

WORKSHEETS
05/13/2025 C9 783 of 1078
05/13/2025 C9 784 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Building Items and Site Work SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Flood containment door 1 EA $10,000 $10,000
2 Demo and install new wet well lighting, Class I Div II 1 LS $9,000 $9,000 3 Remove seal water system 1 LS $1,000 $1,000
4 Demo existing and install new tile roof 1,400 SF $7 $9,800 5 Membrane roof installed over concrete barrel roof 1,600 SF $8 $12,561 6 Floodlights 3 EA $1,000 $3,000
7 Painting and coating, initial application* 1 LS $10,000 $10,000 8 Replace service entrance switchgear 1 LS $205,000 $205,000 9 Security fence at vehicle platform access gate 100 LF $60 $6,000 10 Meter vault crack injection for GW infiltration 2 EA $2,500 $5,000 Total Direct Costs $271,361
SUBTOTAL 271,000$
Contingency: 30% 81,000$
Contractor Overhead and Profit15% 53,000$
State Sales Tax: 4% 16,000$
-
Engineering, Legal and Administrative: 20% 84,000$
TOTAL PROBABLE COST (2015 DOLLARS) 505,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency *Initial painting and coating; touch-up to be performed annually at approx. $3,000/yr 05/13/2025 C9 785 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Fence SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 6' High chain link fencing demolition 500 LF $3 $1,715 2 8' High candy-cane style security fence 500 LF $60 $30,000 3 Remove traffic gate 1 EA $381.00 $381
4 8' High traffic gate 1 EA $5,000.00 $5,000
5 8' High walk gate 1 EA $466.77 $467
Total Direct Costs $37,944
SUBTOTAL 38,000$
Contingency: 30% 11,000$
Contractor Overhead and Profit15% 7,000$
State Sales Tax: 4% 2,000$
-
Engineering, Legal and Administrative: 20% 12,000$
TOTAL PROBABLE COST (2015 DOLLARS) 70,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 786 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Asphalt, Overlay SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 3" Asphalt overlay w/tack coat 18,000 SF $2 $31,320
2 Manholes, raising to grade 2 EA $298 $596
Total Direct Costs $31,916
SUBTOTAL 32,000$
Contingency: 30% 10,000$
Contractor Overhead and Profit15% 6,000$
State Sales Tax: 4% 2,000$
-
Engineering, Legal and Administrative: 20% 10,000$
TOTAL PROBABLE COST (2015 DOLLARS) 60,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 787 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Surge Tank Platform SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Aluminum platform 1 LS $44,000 $44,000
2 Aluminum stairs 13 RSR $561 $7,296
3 Aluminum handrail 150 LF $75 $11,324
Total Direct Costs $62,619
SUBTOTAL 63,000$
Contingency: 30% 19,000$
Contractor Overhead and Profit15% 12,000$
State Sales Tax: 4% 4,000$
-
Engineering, Legal and Administrative: 20% 20,000$
TOTAL PROBABLE COST (2015 DOLLARS) 118,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 788 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Pump Rehabilitation SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Rehabilitate pumps 4 and 5 2 LS $25,000 $50,000
Total Direct Costs $50,000
SUBTOTAL 50,000$
Contingency: N/A -
Contractor Overhead and ProfitN/A -
State Sales Tax: N/A -
-
Engineering, Legal and Administrative: N/A -
TOTAL PROBABLE COST (2015 DOLLARS) 50,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 789 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

FM Valve Replacement and Automation SITE: Buena Vista PS CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Replace 14" discharge and suction plug valves 8 EA $3,893 $31,146 2 Replace 20" forcemain plug valves 3 EA $7,304.39 $21,913 3 Replace 24" forcemain plug valves 3 EA $11,208.39 $33,625 4 Add for Motor Operated Valve 22" to 48" 4 EA $7,000 $28,000 5 Additional crew labor 1 LS $15,000 $15,000
Total Direct Costs $129,684
SUBTOTAL 130,000$
Contingency: 30% 39,000$
Contractor Overhead and Profit15% 25,000$
State Sales Tax: 4% 8,000$
-
Engineering, Legal and Administrative: 20% 40,000$
TOTAL PROBABLE COST (2015 DOLLARS) 242,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 790 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Grinder Improvements SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Demo existing grinder and bar screen 1 EA $10,000 $10,000 2 FM sewage grinder 2 EA $99,806 $199,612
3 Excavation and site work 1 LS $59,880 $59,880
4 Bypass pumping 1 LS $823,000 $823,000
5 Aluminum Stairs, Including Railing And Supports 15 RSR $561 $8,418 6 Aluminum Hatches 1 LS $25,000 $25,000
7 Concrete, FRP grating, slide gates 1 LS $113,006 $113,006 Total Direct Costs $1,238,916
SUBTOTAL 1,239,000$
Contingency: 30% 372,000$
Contractor Overhead and Profit15% 242,000$
State Sales Tax: 4% 74,000$
-
Engineering, Legal and Administrative: 20% 385,000$
TOTAL PROBABLE COST (2015 DOLLARS) 2,312,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 791 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Grinder - Shelf Spare
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Macho Monster Communitor 40002-0024 1 EA $43,000 $43,000 2 3
4 5
6 7
Total Direct Costs $43,000
SUBTOTAL 43,000$
Contingency: % - $
Contractor Overhead and ProfitN/A -
State Sales Tax: 8% 3,000$
-
Engineering, Legal and Administrative: N/A 5,000$
TOTAL PROBABLE COST (2014 DOLLARS) 51,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Prevailing Wages is applied to Subtotal + Contingency
Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 792 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Backflow Preventer SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Demo hydropneumatic tank 1 EA $5,000 $5,000
2 Demo air gap tank 1 EA $10,000 $10,000
3 Backflow preventer 1 EA $10,000 $10,000
4Y a r d w o r k 1 LS $10,000 $10,000
5 Additional pipe modifications 1 LS $2,500 $2,500
Total Direct Costs $37,500
SUBTOTAL 38,000$
Contingency: 30% 11,000$
Contractor Overhead and Profit15% 7,000$
State Sales Tax: 4% 2,000$
-
Engineering, Legal and Administrative: 20% 12,000$
TOTAL PROBABLE COST (2015 DOLLARS) 70,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 793 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Vapor Phase Odor Control SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 2-stage biological scrubber 1 EA $292,188 $292,188
Total Direct Costs $292,188
SUBTOTAL 292,000$
Contingency: 30% 88,000$
Contractor Overhead and Profit15% 57,000$
State Sales Tax: 4% 17,000$
-
Engineering, Legal and Administrative: 20% 91,000$
TOTAL PROBABLE COST (2015 DOLLARS) 545,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency O&M approx. $16,450/yr
05/13/2025 C9 794 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Wet Well Rehabilitation SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Surface preparation 3,000 SF $18 $54,000
2 Concrete repair 1,500 SF $20.00 $30,000
3 Wet well coating 3,000 SF $25.00 $75,000
4 Bypass pumping mob/demob 1 LS $55,000 $55,000
5 Bypass pumping operations 21 Day $12,800 $268,800
Total Direct Costs $482,800
SUBTOTAL 483,000$
Contingency: 30% 145,000$
Contractor Overhead and Profit15% 94,000$
State Sales Tax: 4% 29,000$
-
Engineering, Legal and Administrative: 20% 150,000$
TOTAL PROBABLE COST (2015 DOLLARS) 901,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 795 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Level Monitoring Upgrade SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Demolish existing bubbler system and equipment 1 LS $5,000 $5,000 2 Install pressure transducer level moniroting system 1 LS $10,000 $10,000 Total Direct Costs $15,000
SUBTOTAL 15,000$
Contingency: 30% 5,000$
Contractor Overhead and Profit15% 3,000$
State Sales Tax: 4% 1,000$
-
Engineering, Legal and Administrative: 20% 5,000$
TOTAL PROBABLE COST (2015 DOLLARS) 29,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 796 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 4/1/2016 PROJECT DESCRIPTION:

Exhaust Fan Replacement SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Demo existing fan 2 EA $100 $200
2 Centrifugal exhaust/supply fan, 3600 CFM - electrical room
2 EA $6,019 $12,038
3 Exhaust fan motor, 1 hp - electrical room 2 EA $1,002 $2,004 4 Thermostat 1 EA $338 $338
Total Direct Costs $14,581
SUBTOTAL 15,000$
Contingency: 30% 5,000$
Contractor Overhead and Profit15% 3,000$
State Sales Tax: 4% 1,000$
-
Engineering, Legal and Administrative: 20% 5,000$
TOTAL PROBABLE COST (2015 DOLLARS) 29,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 797 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Assets Nearing End of Useful Life SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Flow meter, forcemain A and B 2 EA $20,000 $40,000
2 Flow transmitter 2 EA $5,000.00 $10,000
3 Gas analyzer 1 EA $5,000.00 $5,000
4 Dry-pit pump replacement (300 hp) 4 EA $75,000 $300,000 5 Adder for electrical (10%) 1 LS $30,000 $30,000
Total Direct Costs $385,000
SUBTOTAL 385,000$
Contingency: 30% 116,000$
Contractor Overhead and Profit15% 75,000$
State Sales Tax: 4% 23,000$
-
Engineering, Legal and Administrative: 20% 120,000$
TOTAL PROBABLE COST (2015 DOLLARS) 719,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 798 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

V & A Projects SITE: Buena Vista PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Replace 20" header spool 1 EA $1,500 $1,500
2 Repair grout pads under pump bases 1 LS $2,000 $2,000 3 Replace connections and fittings - meter vaults 1 LS $10,000 $10,000 4 Coating of equipment/piping - meter vaults 2 EA $5,000 $10,000 5 Bathroom drain and ducting repairs 1 LS $1,000 $1,000 Total Direct Costs $24,500
SUBTOTAL 25,000$
Contingency: 30% 8,000$
Contractor Overhead and Profit15% 5,000$
State Sales Tax: 4% 2,000$
-
Engineering, Legal and Administrative: 20% 8,000$
TOTAL PROBABLE COST (2015 DOLLARS) 48,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 799 of 1078
05/13/2025 C9 800 of 1078
PUMP STATION REHABILITATION STUDY | CITY OF VISTA
FINAL | AUGUST ͮͬͭͲ
Appendix H
RACEWAY PUMP STATION: COST ESTIMATE

WORKSHEETS
05/13/2025 C9 801 of 1078
05/13/2025 C9 802 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Building and Site Improvements SITE: Racewa y PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Double hollow metal door with frame and hardware 2 PR $2,130 $4,261 2 Concrete berm on south side of propert y 120 LF $11.00 $1,320 3 Painting/coating equipment, initial* 1 LS $10,000 $10,000 4 Replace roof floodlight 1 EA $1,000 $1,000
5 Surge protection device for MCC 1 EA $1,000 $1,000
6 Connect pole light fixtures to photoelectric sensor 2 EA $500 $1,000 Total Direct Costs $18,581
SUBTOTAL 19,000$
Contingency: 30% 6,000$
Contractor Overhead and Profit15% 4,000$
State Sales Tax: 4% 1,000$
-
Engineering, Legal and Administrative: 20% 6,000$
TOTAL PROBABLE COST (2015 DOLLARS) 36,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency *Initial painting and coating; touch-up to be performed annually at approx. $3,000/yr 05/13/2025 C9 803 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Fence SITE: Racewa y PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 8' High chain link fence demolition 425 LF $3 $1,338
2 8' High candy-cane style security fence 425 LF $60 $25,500 3 Remove traffic gate 1 EA $381 $381
4 8' High traffic gate 1 EA $5,000 $5,000
5 8' High walk gate 1 EA $467 $467
Total Direct Costs $32,686
SUBTOTAL 33,000$
Contingency: 30% 10,000$
Contractor Overhead and Profit15% 6,000$
State Sales Tax: 4% 2,000$
-
Engineering, Legal and Administrative: 20% 10,000$
TOTAL PROBABLE COST (2015 DOLLARS) 61,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 804 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Overflow Storage Pond SITE: Racewa y PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Concrete curb demolition 245 LF $7 $1,624
2 6" Curved concrete curb 45 LF $11 $509
3 6" Straight concrete curb 200 LF $9 $1,770
4 Aluminum handrail 150 LF $71 $10,724
5 Replace 18" flap gate at emergency overflow pipe 1 EA $8,099 $8,099 6 Apply epoxy/polyurethane coating 2,200 SF $35 $77,000 7 $0
Total Direct Costs $99,725
SUBTOTAL 100,000$
Contingency: 30% 30,000$
Contractor Overhead and Profit15% 20,000$
State Sales Tax: 4% 6,000$
-
Engineering, Legal and Administrative: 20% 31,000$
TOTAL PROBABLE COST (2015 DOLLARS) 187,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 805 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Odor Control Unit SITE: Racewa y PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Demo existing odor control unit 1 LS $2,500 $2,500
2 Install new odor control unit 1 LS $8,000 $8,000
3 EI&C 1 LS $4,000 $4,000
$0
$0
$0
$0
Total Direct Costs $14,500
SUBTOTAL 15,000$
Contingency: 30% 5,000$
Contractor Overhead and Profit15% 3,000$
State Sales Tax: 4% 1,000$
-
Engineering, Legal and Administrative: 20% 5,000$
TOTAL PROBABLE COST (2015 DOLLARS) 29,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 806 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Replace Floating Plug at RPS/Carlsbad Interconnect SITE: Racewa y PS CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Excavation 1 LS $1,200 $1,200
2 Backfill 1 LS $1,320 $1,320
3 Repave 50 SF $10 $490
4 Full port plug valve, 10" 1 EA $3,437 $3,437
5 10" couplings, buried 2 EA $1,109 $2,218
6 Sewer plugs 1 LS $5,000 $5,000
7 Remove and replace storm drain 1 EA $10,000 $10,000
Total Direct Costs $23,666
SUBTOTAL 24,000$
Contingency: 30% 7,000$
Contractor Overhead and Profit15% 5,000$
State Sales Tax: 4% 1,000$
-
Engineering, Legal and Administrative: 20% 7,000$
TOTAL PROBABLE COST (2015 DOLLARS) 44,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 807 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Wet Well Sprayer SITE: Racewa y PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Wet well sprayer 1 EA $43,975 $43,975
Total Direct Costs $43,975
SUBTOTAL 44,000$
Contingency: 30% 13,000$
Contractor Overhead and Profit15% 9,000$
State Sales Tax: 4% 3,000$
-
Engineering, Legal and Administrative: 20% 14,000$
TOTAL PROBABLE COST (2015 DOLLARS) 83,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 808 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 4/1/2016 PROJECT DESCRIPTION:

Exhaust Fan Replacement SITE: Racewa y PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Demo exisitng exhaust fan 1 EA $100 $100
2 Centrifugal exhaust fan, 600 CFM 1 EA $5,296 $5,296
3 Fan motor, 0.5 hp 1 EA $981 $981
Total Direct Costs $6,377
SUBTOTAL 6,000$
Contingency: 30% 2,000$
Contractor Overhead and Profit15% 1,000$
State Sales Tax: 4% - $
-
Engineering, Legal and Administrative: 20% 2,000$
TOTAL PROBABLE COST (2015 DOLLARS) 11,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 809 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

RPS - Pressure Surge Improvements
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Hydropneumatic Surge Control System (1,000 gal) 1 EA $70,000 $70,000 2 Site preparation (earthwork, foundation, piping) 1 LS $73,100 $73,100 3 Electrical (25%) 1 LS $35,775 $35,775
4 Vacuum relief valves 2 EA $50,000 $100,000
5 6
7 Total Direct Costs $278,875
SUBTOTAL 279,000$
Contingency: 30% 84,000$
Contractor Overhead and Profit15% 54,000$
State Sales Tax: 4% 17,000$
-
Engineering, Legal and Administrative: 20% 87,000$
TOTAL PROBABLE COST (2014 DOLLARS) 521,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Prevailing Wages is applied to Subtotal + Contingency
Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 810 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Assets Nearing End of Useful Life SITE: Racewa y PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Install chopper pumps 3 EA $25,000 $75,000
2 Adder for electrical 1 LS $7,500 $7,500

15.0% $12,375
Total Direct Costs $94,875
SUBTOTAL 95,000$
Contingency: 25% 24,000$
Contractor Overhead and Profit15% 18,000$
State Sales Tax: 4% 5,000$
-
Engineering, Legal and Administrative: 20% 28,000$
TOTAL PROBABLE COST (2014 DOLLARS) 170,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Prevailing Wages is applied to Subtotal + Contingency
Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 811 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 4/1/2016 PROJECT DESCRIPTION:

V & A Recommendations SITE: Racewa y PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Replace corroded conduits at electrical box 1 LS $5,000 $5,000 $0
$0
$0
$0
$0
Total Direct Costs $5,000
SUBTOTAL 5,000$
Contingency: 30% 2,000$
Contractor Overhead and Profit15% 1,000$
State Sales Tax: 4% - $
-
Engineering, Legal and Administrative: 20% 2,000$
TOTAL PROBABLE COST (2015 DOLLARS) 10,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 812 of 1078
PUMP STATION REHABILITATION STUDY | CITY OF VISTA
FINAL | AUGUST ͮͬͭͲ
Appendix I

BUENA CREEK PUMP STATION COST ESTIMATE

WORKSHEETS
05/13/2025 C9 813 of 1078
05/13/2025 C9 814 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Wet Well Rehabilitation SITE: Buena Creek PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 General Conditions & Mob/Demob (10%) 1 LS $48,000 $48,000 2 Wet Well Liner (Div. 06 - Wood and Plastics) 1 LS $421,000.00 $421,000 3 Equipment 1 LS $56,000.00 $56,000
4 5
6 Total Direct Costs $525,000
SUBTOTAL 525,000$
Contingency: %
Contractor Overhead and ProfitN/A
State Sales Tax: N/A
Engineering, Legal and Administrative: N/A
TOTAL PROBABLE COST (2015 DOLLARS) 525,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 815 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Odor Control Unit Repair SITE: Buena Creek PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Patch and paint fiberglass housing 1 LS $5,000 $5,000 2 Replace blower control panel pilot light 1 EA $1,000 $1,000 Total Direct Costs $6,000
SUBTOTAL 6,000$
Contingency: N/A -
Contractor Overhead and ProfitN/A -
State Sales Tax: N/A -
-
Engineering, Legal and Administrative: N/A -
TOTAL PROBABLE COST (2015 DOLLARS) 6,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 816 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Wet Well Sprayers SITE: Buena Creek PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Wet well sprayers 1 LS $103,368 $103,368
Total Direct Costs $103,368
SUBTOTAL 103,000$
Contingency: 30% 31,000$
Contractor Overhead and Profit15% 20,000$
State Sales Tax: 4% 6,000$
-
Engineering, Legal and Administrative: 20% 32,000$
TOTAL PROBABLE COST (2015 DOLLARS) 192,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 817 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 4/1/2016 PROJECT DESCRIPTION:

Exhaust Fan Replacement SITE: Buena Creek PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Demo existing fan 2 EA $100 $200
2 Centrifugal exhaust fan, 2250 CFM -pump room 1 EA $5,296 $5,296 3 Exhaust fan motor, 1.5 hp - pump room 1 EA $1,219 $1,219 4 Centrifugal roof supply fan, 7000 CFM - building 1 EA $7,111 $7,111 5 Supply fan motor, 3 hp - building 1 EA $1,994 $1,994
Total Direct Costs $15,820
SUBTOTAL 16,000$
Contingency: 30% 5,000$
Contractor Overhead and Profit15% 3,000$
State Sales Tax: 4% 1,000$
-
Engineering, Legal and Administrative: 20% 5,000$
TOTAL PROBABLE COST (2015 DOLLARS) 30,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Contractor Overhead and Profit is applied to Subtotal + Contingency Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 818 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Pump Selection Programming
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Pump Selection Programming 1 LS $100,000 $100,000
2 3
4 5
6 7
Total Direct Costs $100,000
SUBTOTAL 100,000$
Contingency: % - $
Contractor Overhead and ProfitN/A -
State Sales Tax: N/A -
-
Engineering, Legal and Administrative: N/A -
TOTAL PROBABLE COST (2014 DOLLARS) 100,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Prevailing Wages is applied to Subtotal + Contingency
Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 819 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Pressure Surge Improvements
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Hydropneumatic Surge Control System (5,000 gal) 1 EA $95,000 $95,000 2 Site preparation (earthwork, foundation, piping) 1 LS $92,621 $92,621 3 Electrical (25%) 1 LS $46,905 $46,905
4 Vacuum relief valves 4 EA $50,000 $200,000
5 6
7 Total Direct Costs $434,526
SUBTOTAL 435,000$
Contingency: 30% 131,000$
Contractor Overhead and Profit15% 85,000$
State Sales Tax: 4% 26,000$
-
Engineering, Legal and Administrative: 20% 135,000$
TOTAL PROBABLE COST (2014 DOLLARS) 812,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Prevailing Wages is applied to Subtotal + Contingency
Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 820 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

Assets Nearing End of Useful Life SITE: Buena Creek PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Flow meter, Shadowridge 1 LS $10,000 $10,000
2 Flow meter, Encina 1 LS $15,000 $15,000
3 Wet/dry well gas analyzer 1 LS $5,000 $5,000
4 Rehabilitation of sewage pumps 5 EA $5,000 $25,000
5 Adder for Electric 1 LS $8,250 $8,250
Total Direct Costs $63,250
SUBTOTAL 63,000$
Contingency: 30% 19,000$
Contractor Overhead and Profit15% 12,000$
State Sales Tax: 4% 4,000$
-
Engineering, Legal and Administrative: 20% 20,000$
TOTAL PROBABLE COST (2014 DOLLARS) 118,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Prevailing Wages is applied to Subtotal + Contingency
Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 821 of 1078
8/17/2016
PROJECT: Pump Station Rehab and VFD/PLC Replacement DATE: 11/11/2015 PROJECT DESCRIPTION:

V & A Recommendations SITE: Buena Creek PS
CLIENT: City of Vista

ITEM SCHEDULE OF VALUES
NO. DESCRIPTION QNTY UNIT UNIT PRICE TOTAL COST
1 Cathodic Protection 1 LS $1,000,000 $1,000,000
2 3
4 5
Total Direct Costs $1,000,000
SUBTOTAL 1,000,000$
Contingency: 30% 300,000$
Contractor Overhead and Profit15% 195,000$
State Sales Tax: 4% 60,000$
-
Engineering, Legal and Administrative: 20% 311,000$
TOTAL PROBABLE COST (2014 DOLLARS) 1,866,000$
Notes:

ENGINEER'S OPINION OF PROBABLE COST
Contingency is applied to Subtotal
Prevailing Wages is applied to Subtotal + Contingency
Sales Tax, as applicable, is applied to Subtotal + Contingency + Prevailing Wages Engineering, Legal and Administrative is an estimate based on Subtotal + Contingency 05/13/2025 C9 822 of 1078
PUMP STATION REHABILITATION STUDY | CITY OF VISTA
FINAL | AUGUST ͮͬͭͲ
Appendix J
RACEWAY PUMP STATION: GRINDER

INVESTIGATION LETTER REPORT
05/13/2025 C9 823 of 1078
05/13/2025 C9 824 of 1078
Project No 9936A.10 | Letter report_RPS grinder.docx 5075 Shoreham Place, Suite 120, San Diego, California 92122 P. 858.505.1020 F. 858.505.1015
carollo.com
August 31, 2015
Mr. Alfred Pedroza
City of Vista
200 Civic Center Drive
Vista, CA 92084
Subject: City of Vista - Grinder Replacement at Raceway Pumping Station Dear Mr. Pedroza:

This letter report highlights Carollo's investigation into installation of new grinders at the City of Vista's (City) Raceway Pump Station (RWPS).

BACKGROUND
The RWPS is a sewage lift station with a design capacity of 2.1 million gallons per day (mgd).

As wastewater enters the RWPS, it passes through a sewage grinder prior to entering the pump station wet well. The grinder consists of two shafts of cutters that spin in opposite directions.

The cutters shred large debris and rags to prevent "pump ragging," which occurs when rags wrap around the pump impellers. Pump ragging can damage the pumps, motors and variable frequency drives (VFD) downstream. If the grinder is offline, or removed for servicing, the flow is diverted to a PVC pipe rack that requires labor-intensive manual cleaning by Encina staff.

Under current operations, the Moyno grinder has been out of service for over six months and is currently having a complete motor rebuild. The pipe rack allows rags to pass through intact and has resulted in at least one instance of a pump ragging. The ragging was sever enough to result in significant damage to the pump VFD and required replacement. Replacement of the existing set-up with a grinder in each channel is desired.

DESIGN CRITERIA
Each grinder should be able to match the existing pump station capacity so that redundancy is maintained for each of the influent channels. The existing channels are 4.25 feet (ft.) wide by

1.9 ft. long with a maximum water depth of 2.47 ft. The channels are separated by a concrete wall and a weir that diverts flow to the bar screen (or second grinder) channel as needed.

Installation of mechanical equipment in each channel does increase the risk of a pump station overflow if both devices were to fail. New grinders should be capable of motor submersion to allow an overflow bypass in the event of failure.

ALTERNATIVES
Two JWC Environmental Open Channel Grinders have been evaluated for use at RWPS, the 30005 Series Wipes Ready Muffin Monster and the Wipes Ready CMD Series Channel 05/13/2025 C9 825 of 1078
Mr. Alfred Pedroza
City of Vista
August 31, 2015

Page 2 ends