STANDARDS
3/ 4" THICK PLYWOOD ADJUSTABLE
SHELF WITH WHITE MELAMINE FINISH,
TYP.
WHITE MELAMINE FINISH, TYP.
PULLS, ALL PULLS SHALL ALIGN, TYP.
3/ 4" THICK PLYWOOD WITH PLASTIC
LAMINATE, SEE FINISH SCHEDULE
6"
5"
5"
5"
5"
5"
5"
1/ 2" THICK PLYWOOD WITH PLASTIC
LAMINATE FIXED SHELVES, SEE FINISH
SCHEDULE
1'-3"
8'-
4"3'-
0"
2'-
10"
SEALANT AT CORNERS, TYP.
WAINSCOT, SEE FINISH SCHEDULE
WATER RESISTANT GYPSUM BOARD
WALL PER PLAN
WATER RESISTANT GYPSUM BOARD
WAINSCOT, SEE FINISH SCHEDULE
PLYWOOD SHEATHING WHERE
OCCURS, SEE STRUCTURAL
WALL PER PLAN
WATER RESISTANT GYPSUM BOARD
WAINSCOT, SEE FINISH SCHEDULE
1 1/ 2"
1 1/
2"
CORNER GUARD
FACE OF WALL
GYPSUM BOARD, SEE ROOM
FINISH SCHEDULE FOR TYPE
1 1/ 2"
1 1/
2"
CORNER GUARD, ALIGN
WITH TOP OF WAINSCOT
FACE OF WALL
WAINSCOT AS SCHEDULED
GYPSUM BOARD, SEE ROOM
FINISH SCHEDULE FOR TYPE
FINISH FLOOR AS SCHEDULED
WALL BASE AS SCHEDULED
TERMINATE FRP TRIM, ALIGN
WITH TOP OF WALL BASE
FRP TRIM
FRP WAINSCOT AS SCHEDULED
FACE OF WALL
GYPSUM BOARD, SEE ROOM
FINISH SCHEDULE FOR TYPE
3"3"
3"
SOLID SURFACE TRIM AT ALL MIRRORS
AND PAPER TOWEL DISPENSERS THAT
INTERSECT SOLID SURFACE WAINSCOT,
U.O.N
ECKEFRAI
REN. 09/10/21
FEAT
ST
LFCAOI
L FEJ
C018223
OAINR
ATZ T
SNEC Y
DE CARTHI
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/20
02/ 11/21
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
DETAILS
200102
A7.9
BC
JK
GG
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:1" = 1'-0"A7.9
A2 UPPER CASEWORK
SCALE:1" = 1'-0"A7.9
B2 COUNTERTOP WITH LAVATORY
SCALE:1" = 1'-0"A7.9
A3 BASE CASEWORK
SCALE:1" = 1'-0"A7.9
B1 CASEWORK
SCALE:1" = 1'-0"A7.9
B3 BASE CASEWORK
SCALE:1" = 1'-0"A7.9
B4 MAIL SLOT CASEWORK
SCALE:3" = 1'-0"A7.9
C2 WAINSCOT AT INSIDE EDGE
SCALE:3" = 1'-0"A7.9
C3 WAINSCOT
SCALE:3" = 1'-0"A7.9
C4 WAINSCOT AT CORNER
SCALE:6" = 1'-0"A7.9
D4 CORNER GUARD
SCALE:6" = 1'-0"A7.9
D3 CORNER GUARD AT WAINSCOT
SCALE:6" = 1'-0"A7.9
D2 FRP WAINSCOT WAINSCOT AT RUBBER BASE
SCALE:1/2" = 1'-0"A7.9
C1 SOLID SURFACE TRIM
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 267 of 357
1 1/ 2"
WALL PER PLAN
2X BLOCKING
CEMENTITIOUS BACKER BOARD
GRAB BAR, SEE D3/T-3
AND T-4
WAINSCOT, SEE FINISH
SCHEDULE
ATTACH GRAB BAR THRU WALL WITH
MOUNTING SCREWS TO 2X6 WOOD
BACKING PLATE SECURELY
FASTENED BETWEEN STUDS AS
REQUIRED
SLOPE TO
DRAI N
SLOPE TO
DRAI N
CONCRETE SLAB ON
GRADE, SEE CIVIL
FLOOR DRAIN, SEE PLUMBING
SLOPE TO
DRAI N
SLOPE TO
DRAI N
CONCRETE SLAB ON
GRADE, SEE CIVIL
FLOOR SINK, SEE PLUMBING
TOP OF MIRROR
FRENCH CLEAT
FACE OF WALL
20 WALL PER PLAN
GYPSUM BOARD, SEE ROOM FINISH
SCHEDULE FOR TYPE
RUBBER MAT BASE, SEE FINISH
SCHEDULE
MIRROR
2"x3/16" ALUMINUM FLAT BAR
BRACKET. FIELD VERIFY
BRACKET LOCATIONS
2" ALUMINUM TUBE FRAME
ALUMINUM SERRATED
RUNGS 1-1/ 4" SQ AT 12"OC MAX
ACCESS HATCH
LINE SHAFT WITH PLYWOOD
AND PAINT TO MATCH
1'-
0 1'-
0 6"
22"
V.I.F.
2"x3/16" ALUMINUM
FLAT BAR BRACKET
SOLID BLOCKING
8"
1'-
0 1'-
0 1'-
6 T.O.P. 1
13' -6"
MTL
3 2" STROKE, ALUMINUM PLATE CUT
OUT LETTERS IN TW CEN MT FONT,
MOUNTED WITH 3/4" STANDOFFS,
FACTORY APPLIED BAKED ENAMEL
FINISH
1'-3"3'-6"
1'-
2 1'-
4 4'-
0 1/ 4" THICK DIBOND,
DIGITALLY PRINTED
1440 DPI IN UV INK
WITH CLEAR
ANTI-GRAFFITI
CLEAR COAT
EQ 5'-0"EQ
MCM
1 4"
7"
11 1'-
1 1
EQ.10'-5"EQ.
2" STROKE, ALUMINUM
MOUNTED WITH 3/4"
STANDOFFS, FACTORY
APPLIED BAKED ENAMEL
FINISH
2" STROKE, ALUMINUM
MOUNTED WITH 3/4"
STANDOFFS, FACTORY
APPLIED BAKED ENAMEL
FINISH
2" STROKE, ALUMINUM
PLATE CUT OUT LETTERS IN
TIMES NEW ROMAN
FONT, MOUNTED WITH
3/4" STANDOFFS,
FACTORY APPLIED BAKED
ENAMEL FINISH
1" STROKE, ALUMINUM
PLATE CUT OUT LETTERS IN
CENTURY GOTHIC FONT,
MOUNTED WITH 3/ 4"
STANDOFFS, FACTORY
APPLIED BAKED ENAMEL
FINISH
C
EN
TER
LO
G
O
O
N
P
A
N
EL
EQ.8'-6"EQ.
EQ.9'-2"EQ.
THIS DOOR TO REMAIN UNLOCKED WHEN THIS SPACE IS OCCUPIED'
LETTERS SHALL BE
UPPER CASE, SAN
SERIF TYPE, 1" HIGH
1"
42" ABOVE THE
ATTIC DECK
SURFACE
FIRE RETARDENT FRP
SELF-CLOSING FRP
GATE
ALUMINUM POST
SUPPORTS
ALUMINUM POST
HINGE
STEEL CORNER BRACKETS
HOT DIP GALVANIZED)
STAINLESS STEEL TORSION
ROD
ALUMINUM GATE HINGE
SAFETY EXTENSION ROD
STEEL CORNER BRACKETS (HOT
DIP GALVANIZED)
SAFETY EXTENSION ROD
20 GA. x 6" WIDE FLAT STOCK AND (2) #S12 S.M.S. TOP AND BOTTOM EACH END. FLAT STOCK TO EXTEND ACROSS
MINIMUM 3 STUDS
STUDS PER WALL TYPE DESIGNATION
NOTE:
1. APPLY BACKING AT CASEWORK, T.V., GUARD RAILS, GRAB BARS, MIRRORS,
WHITE BOARDS, DOOR STOPS, LOCKERS, FANS, AND OTHER TYPICAL LOCATIONS OF WALL MOUNTED EQUIPMENT.
ECKEFRAI
REN. 09/10/21
FEAT
ST
LFCAOI
L FEJ
C018223
OAINR
ATZ T
SNEC Y
DE CARTHI
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/20
02/ 11/21
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
DETAILS
200102
A7.10
BC
JK
HB
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:3" = 1'-0"A7.10
A2 GRAB BAR MOUNTING DETAIL
SCALE:3" = 1'-0"A7.10
A3 FLOOR DRAIN AT CONCRETE FLOOR
SCALE:3" = 1'-0"A7.10
A4 FLOOR SINK AT CONCRETE FLOOR
SCALE:6" = 1'-0"A7.10
B3 MIRROR WALL MOUNTING
SCALE:1 1/ 2" = 1'-0"A7.10
B4 MIRROR WALL MOUNTING AT BASE
SCALE:1/ 2" = 1'-0"A7.10
B2 ROOF ACCESS LADDER
SCALE:1" = 1'-0"A7.10
C2 EXTERIOR BUILDING SIGNAGE - ADDRESS
SCALE:1" = 1'-0"A7.10
D2 EXTERIOR BUILDING SEAL
SCALE:1" = 1'-0"A7.10
D3 EXTERIOR BUILDING SIGNAGE
SCALE:3" = 1'-0"A7.10
D1 EGRESS DECAL
SCALE:1" = 1'-0"A7.10
C1 ROOF ACCESS SAFETY RAIL DETAIL
SCALE:1" = 1'-0"A7.10
B1 ROOF ACCESS DETAIL
SCALE:3" = 1'-0"A7.10
A1 TYPICAL WALL BACKING PLATE
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 268 of 357
STRUCTURAL
NOTES
S1.0
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 269 of 357
STRUCTURAL
NOTES
S1.1
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 270 of 357
Table 25.3.1—Standard hook geometry for development of deformed bars in tension
Type of
standard
hook Bar size
No. 3 through
No. 8
90-degree
hook
No. 9 through
No. 11
No. 14 and
No. 18
No. 3 through
No. 8
180-degree
hook
No. 9 through
No. 11
No. 14 and
No. 18
Minimum inside
bend diameter, in.
6db
8db
12db
10db
6db
8db
10db
Greater of
4db and 2.5 in.
Straight
extension[1]
Lext, in.Type of standard hook
Table 25.3.2—Minimum inside bend diameters and standard hook geometry for stirrups, ties, and hoops
Type of stan-
dard hook Bar size
90-degree
hook
No. 3
through
No. 5
No. 6
through
No. 8
135-degree
hook
No. 3
through
No. 5
No. 6
through
No. 8
180-degree
hook
No. 3
through
No. 5
No. 6
through
No. 8
Minimum inside
bend diameter, in.
4db
6db
4db
Greater of 6db and
3 in.
6db
4db
6db
Straight extension[1]
Lext, in.
Greater of 6db and
3 in.
12db
Type of standard hook
Greater of
4db and
2.5 in.
TYPICAL
STRUCTURAL
DETAILS
S1.2
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 271 of 357
TYPICAL
STRUCTURAL
DETAILS
S1.3
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 272 of 357
TYPICAL
STRUCTURAL
DETAILS
S1.4
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 273 of 357
TYPICAL
STRUCTURAL
DETAILS
S1.5
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 274 of 357
TYPICAL
STRUCTURAL
DETAILS
S1.6
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 275 of 357
1 1
2 2
3 4
5 6
6 7 8 9
10 A
B
C C
D D
E E
F
G
H H
J J
5" CONC. SLAB ON GRADE
REINF. W/ #4 @ 18" O.C. EA. WAY
OVER 15 MIL. VAPOR BARRIER
OVER 4" OF SAND
AF.L.W
A
F.L.W.
A
F.L.W.
AF.L.W
A
F.L.W
A
F.L.W
A
F.L.W
A
F.L.W.
A
F.L.W.
AF.L.W
C
F.L.W.
B
F.L.W.
CF.L.W
BF.L.W
A
F.L.W
A
F.L.W
A
F.L.W
A
F.L.W.
6x6
6x6
6x6
6x6
6x6
6x6
6x6 6x6
6x6 6x6 6x6 6x6
6x6
6x6 6x6
6x6
6x6
6x6
6x6 6x6
6x6
6x6
6x6
6x6
HSS4X4X1/4 HSS4X4X1/4
1 S3.1
2 S3.1
6x6 6x6
HSS4X4X1/4
HSS4X4X1/4
FS
FD
FD FD
8" CMU WALL
6x6 6x6 6x6
W.P.J.
W.
P
J
FD
FD FD
FD
FD
FD
FD
1 S4.1
1 S4.1
1 S4.1
1 S4.1
1 S4.1
1 S4.1
1 S4.1
1 S4.1
1 S4.1
2 S4.1
4 S4.1
TYP.
3 S4.1 TYP.
5 S4.1 TYP.
6 S4.1 TYP.
7 S4.1
TYP.
3 S4.1TYP.
HSS4X4X1/4
HSS4X4X1/4
HSS4X4X1/4
HSS4X4X1/4
HSS4X4X1/4
6x6
HSS4X4X1/4
HSS4X4X1/4
8 S4.1
TYP.
HSS4X4X1/4
HSS4X4X1/4
6x6
6x6
A
F.L.W
1 S4.5
6x6
A
F.L.W
A
F.L.W.
A
F.L.W.
A
F.L.W.
A
F.L.W.
A
F.L.W.
A
F.L.W.
4 S4.1
TYP.
HSS4X4X1/4
0' -
11 1
4 1' - 11"
0' - 11 1/4"
1' -
11 0' -
11 1
4 4' - 5 1/2"
0' - 11 1/4"
1' -
11 0' -
11 1
4 1' - 11"
7 S4.1
SIM.
TYP.
2 S4.5
FD
6x6 6x6
6x6 6x6
3' -
0 2' - 6"
3' - 0"
2' -
6 4
4 A
F.L.W.
2 2 2 2
2 2
A
F.L.W.
C
F.L.W.
5 52
2 4
4 3
S1.6
TYP.
W.
P
J
W.P.J.
W.
P
J
W.
P
J
2 2
2 S4.1
2 S4.1
1 S4.1
HSS4X4X1/4
6x6
6x6
A
F.L.W
A
F.L.W
3 S4.1
TYP.
TYP.
9 S4.1
6x6
BF.L.W
4 4
3' - 0"
6x6
LEGEND:
INDICATES WALL AT THIS LEVEL
INDICATES POST STARTS AT THIS LEVEL
INDICATES HOLDOWN
INDICATES CONCRETE CURB AT WALL
INDICATES PLYWOOD FOR FULL LENGTH
OF WALL
INDICATES FLOOR DRAIN, SLOPE FLOOR
TO DRAIN
INDICATES FLOOR SINK
INDICATES SLAB JOINT PER
INDICATES DEPRESSED SLAB
POST
F.L.W.
FD
FS
W.P.J.
NOTES:
1. FOR DIMENSIONS NOT SHOWN, SEE ARCH.
2. FINISH FLOOR REFERENCE DATUM
ELEVATION = 0'-0", U.O.N.
3. INDICATES PLYWOOD SHEARWALL PER
4. INTERIOR WALLS WITH FOOTINGS SHALL BE FULL
HEIGHT
6. FOR NON-BEARING WALL CONNECTION AT BASE,
SEE
7. ALL HOLDOWN ANCHORS SHALL BE TIED IN PLACE
PRIOR TO FOUNDATION INSPECTION, SEE
8. FOR OPENING IN SHEARWALL PANELS, SEE
9. FOR PIPES THRU FOOTING, SEE
10. SPECIAL INSPECTION IS REQ'D, SEE SHEET S1.0
11. SEE GENERAL NOTES AND TYPICAL DETAILS ON S1.0,
S1.1, S1.2, S1.3, S1.4, S1.5, AND S1.6
2 S1.3
9 S1.5
2 S1.3
1 S1.2
6 S1.4
3 S1.5
7 S1.5
3 S1.6
D
DONLA EIORR.
NG
C
EXP. 12- 31-22
ETA OF
TS
RE
TSUR
RNOIACLFRTUALAI
REE
EF
DER
ISTE
RPO SASNOI
EGIN
L
No. S3838
OrieEngineering2
OR IE 2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
Structural and Bridge Engineers
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
FOUNDATION
PLAN
200102
S2.0
DRO
DRO
RCH
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:1/8" = 1'-0"S2.0
1 FOUNDATION PLAN
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 276 of 357
1 1
2 2
3 4
5 6
6 7 8 9
10 10
A
B
C C
D D
E E
F
G
H H
J J
5 1/4"x11 7/8" LVL
5 1
4 x11
7 8
LVL
3 1/2"x11 7/8" LVL
5 1/4"x11 7/8" LVL
6x8 6x8 6x8
5 1/4"x11 7/8" LVL
5 1/4"x11 7/8" LVL
6x8
5 1/4"x16" LVL 5 1/4"x14" LVL
5 1/4"x9 1/2" LVL
6x1051/4"x11 7/8" LVL6x10
6x6
6x6
6x6
6x6
6x6
6x6
6x6
6x6
6x6
6x66x66x6
6x6
6x6
6x6
6x66x6
6x6
6x6 6x6
6x8
6x6
6x6
6x6
6x6
5 1/4"x11 7/8" LVL
6x6
5 1
4 x11
7 8
LVL
5 1/4"x11 7/8" LVL
5 1/4"x11 7/8" LVL6x6K.P.6x6
ROOF JOISTS: 14" RED-I 45 @ 24" O.C. U.O.N.
1 S3.1
2 S3.1
5 1/4"x14" LVL
5 1/4"x11 7/8" LVL
6x6
6x6
6x86x8
6x8
2x14
6x6
6x6
6x6
6x6
1 S4.2
2 S4.2
2 S4.2
1 S4.2
2 S4.2
3 S4.2
TYP.
4 S4.2
5 S4.2TYP.
5 S4.2
TYP.
6 S4.2
7 S4.2
11 S4.2
8 S4.2
9 S4.2TYP.
1 S1.6 TYP.
5 1
4 x11
7 8
LVL
5 1
4 x11
7 8
LVL
5 1/4"x11 7/8" LVL
5 1/4"x14" LVL51/4"x14" LVL 5 1/4"x14" LVL
HSS10X4X3/
16 HSS10X4X3/16
HSS10X4X3/16
2x12
@
24 O
C
JOISTS
AT
CANOPY
5 1/4"x9 1/2" LVL
5 1/4"x11 7/8" LVL
2 S2.1
TYP.
TYP.
TYP. ROOF PLYWOOD:
1/2" CD-X PLYWOOD
PII 32/16 w/
BOUNDARY NAIL 8d @ 6" O.C.
EDGE NAIL 8d @ 6" O.C.
FIELD NAIL 8d @ 12" O.C.
BLOCK ALL UNSUPPORTED EDGES
FACE GRAIN PERPENDICULAR TO FRAMING
ALL NAILS SHALL BE COMMON WIRE
6x10
1 S4.5
3 S4.3
4 S4.3
1 S4.3
5 1/4"x14" LVL 5 1/4"x14" LVL
5 1
4 x14
LVL
5 1
4 x14
LVL
2x12 @ 16" O.C.
1 S4.2
6 S4.2
5 S4.3
7 S4.3
1 S4.4
2 S4.4
4 S4.4 TYP. AT SOLATUBES
3 S4.4
6x6 K.P.
16" RED-I 65 @ 24" O.C.
2 S4.5
HS
S6X4X1
4 HSS6X4X1
4 HSS6X4X1/4
6x8 6x8
6x6 K.P.
6 S4.3
TYP.
CANT.
CA
NT
SIMPSON HUCQ
HANGER
7 S4.2
CA
NT
TYP.
SIM.
8 S4.3
6 S4.3
2 S4.3
TYP.
5 1/4"x11 7/8" LVL
5 1/4"x11 7/8" LVL
5 1/4"x11 7/8" LVL
SIMPSON HUCQ
HANGER
5 1/4"x14" LVL
SIMPSON HUCQ
HANGER
SIMPSON MSTI48
STRAP
SIMPSON MSTI48
STRAP
SIMPSON MSTI48
STRAP
CANT.
CANT.
SIMPSON HUCQ
HANGER
6 S4.4
5 S4.4 TYP.
6x6 6x6 6x6 6x6 6x6 6x6
4 S4.6
SIMPSON
HUCQ
HANGER
SIMPSON
HUCQ HANGER
6 S4.6
DBL. JOIST
2x4 BRACE TYP.
5 S4.5
6x6
SIMPSON MSTI48
STRAP
1 S1.6
TYP. BEAM
TO POST
1 S4.6 1
S4.6
2 S4.6
3 S4.6
TYP. @
EXHAUST FANS
TYP.
TYP.
5 S4.6
6x6
TYP.
HEADER
9 S4.2
4 S4.2TYP.
SIM.
RIDGE
SLOPE
1/
2 12
SLOPE
1/
2 12
SLOPE
1/
2 12
30" CLR. MIN.
30" CLR. MIN.
4'-0" CLR. BETWEEN ROOF
SCUPPER AND NEAREST
BRACE ON EA. SIDE, TYP.
2x1
2 @
16 O
C
@
EYEBROW
2x12 @ 16" O.C. @ EYEBROW
2x12 @ 24' O.C.
U.O.N.
5 S4.4TYP.
INDICATES WALL BELOW
INDICATES BEARING LINE BELOW
INDICATES WOOD JOIST
INDICATES CANTILEVER SECTION OF
BEAM
LEGEND:
1. FOR DIMENSIONS NOT SHOWN, SEE ARCH.
2. FINISH FLOOR REFERENCE DATUM
ELEVATION = 0'-0", U.O.N.
3. FOR NON-BEARING WALL CONN. @ TOP, SEE
4. FOR PIPES THRU SILL PLATES, SEE
5. SPECIAL INSPECTION IS REQ'D, SEE SHEET S1.0
6. FOR STRAPS AT CORNER OF BUILDING, SEE
7. FOR SOLAR PANEL CONNECTION TO EXISTING CARPORTS
SEE S4.7.
8. SEE GENERAL NOTES AND TYPICAL DETAILS ON S1.0,
S1.1, S1.2, S1.3, S1.4, S1.5, AND S1.6.
7 S1.4
4 S1.3
8 S1.4
NOTES:
CANT.
8 9
10 10
C C
D D
5 1
4 x11
7 8
LVL
5 1
4 x11
7 8
LVL
2x6
@
24 O
C
HIGH
ROOF
JOISTS
2 S4.4
D
DONLA EIORR.
NG
C
EXP. 12- 31-22
ETA OF
TS
RE
TSUR
RNOIACLFRTUALAI
REE
EF
DER
ISTE
RPO SASNOI
EGIN
L
No. S3838
OrieEngineering2
OR IE 2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
Structural and Bridge Engineers
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ROOF
FRAMING PLAN
200102
S2.1
DRO
DRO
RCH
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:1/8" = 1'-0"S2.1
1 ROOF FRAMING PLAN
SCALE:1/8" = 1'-0"S2.1
2 ROOF FRAMING PLAN - HIGH ROOF
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 277 of 357
T.O.P. 1
13' - 6"
T.O.P. 2
16' - 6"
T.O.P. 2
16' - 6"
JCAD
F.F.
0' - 0"
T.O.P. 3
21' - 9"
T.O.P. 1
13' - 6"
LEVEL 1
0' - 0"
T.O.P. 2
16' - 6"
JCBDFH
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
S3.1
SCALE: 1/4" = 1'-0"S3.1
2 STRUCTURAL BUILDING SECTION
STRUCTURAL
SECTIONS
SCALE:1/4" = 1'-0"S3.1
1 STRUCTURAL BUILDING SECTION
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 278 of 357
STRUCTURAL
DETAILS
S4.1
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 279 of 357
S2.5
S2.5
S2.5
S2.5
STRUCTURAL
DETAILS
S4.2
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 280 of 357
STRUCTURAL
DETAILS
S4.3
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 281 of 357
STRUCTURAL
DETAILS
S4.4
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 282 of 357
CD
STRUCTURAL
DETAILS
S4.5
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 283 of 357
STRUCTURAL
DETAILS
S4.6
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 284 of 357
STRUCTURAL
DETAILS
S4.7
Description:Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
RCH
DRO
DRO
OrieEngineering2
Structural and BridgeEngineersORIE2
STRUCTURAL
BRIDGE
9750 Miramar Road, Suite 310
San Diego, CA 92126
www.Orie2.com
200102
D
DON
LA EIORR.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 285 of 357
14"ø
12"ø
10"ø
TITUS
PAR3FW
MANUFACTURERMARK
6"ø
8"ø
SIZE
TITUS
PCS3FW
FACE
20" x 20"
20" x 20"
16" x 16"
12" x 12"
301 TO 450
16"ø
24" x 24"
201 TO 300
101 TO 200
451 TO 600
601 TO 800
O TO 100
STEEL PERFORATED NECK MOUNTED
CURVED BLADE DEFLECTORS, LAY-IN
BORDER TYPE 3, HARD LID BORDER
FLUSH FACE
0 TO 100
101 TO 250
251 TO 400
401 TO 600
601 TO 800
801 TO 1000
14"ø
12"ø
10"ø
6"ø
8"ø
20" x 20"
20" x 20"
16 "x 16"
16" x 16"
12" x 12"
16"ø
20" x 20"
SUPPLY DIFFUSER
RETURN / EXHAUST REGISTER
12" x 12"
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
24" x 24"LAY-IN
HARD LID
NECK
MODEL CFM RANGE REMARKS
AIR DISTRIBUTION SCHEDULE
18"x18"800 TO140020"x20"SIDEWALL 300 RS PLENUM MOUNTED
0 TO50018"x12"20"x14"SIDEWALL STEEL RETURN GRILLE, 3/4" BLADE SPACING. RETURN AIR TRANSFER
12"x6"800 TO140015"x9"SIDEWALL 300 RL
14"ø
12"ø
10"ø
6"ø
8"ø
TMRA
381 TO 550
16"ø -
281 TO 380
141 TO 280
551 TO 745
746 TO 980
O TO 140ROUND
ROUND
ROUND
ROUND
ROUND
ROUND
NOTES:
1. ALL SUPPLY DIFFUSERS SHALL BE SELECTED AT A MAX. 30 NC.
2. DIFFUSER BRANCH DUCTWORK SHALL BE THE SAME SIZE AS THE DIFFUSER NECK.
3. REFER TO ARCHITECTURAL PLANS FOR CEILING TYPES.
4. GRILLE FINISH TO MATCH ADJACENT FINISH.
A
STEEL PERFORATED RETURN DIFFUSER,
LAY-IN BORDER TYPE 1, HARD LID
BORDER FLUSH FACE
B
C
D
E
F
G
H
I
J
K
L
M
N
AA
BB
CC
DD
EE
FF
GG
24"x14"HH
0 TO2258"x8"STEEL RETURN GRILLE, 3/4" BLADE
SPACINGII10"x10"SIDEWALL
0 TO100036"x12"STEEL RETURN GRILLE, 3/4" BLADE
SPACING. RETURN AIRTRANSFERJJ38"x14"SIDEWALL
350 RL O°
DEFLECTION
SIDEWALL 26"x16"
0 TO50018"x14"STEEL RETURN GRILLE, 3/4" BLADE
SPACING. RETURN AIRTRANSFERKK20"x16"SIDEWALL
STEEL RETURN GRILLE, 3/4" BLADE
SPACING. RETURN AIR TRANSFER
0 TO250LL10" x 10"HARD LID50F8"x8"ALUMINUM EXHAUST GRILLE, 1/2"x1/2"x1/2" CORE SIZE. ALUMINUM GRID AND BORDER.
GENERAL NOTES
1. ALL CONTRACT DRAWINGS AND SPECIFICATIONS ARE COMPLEMENTARY TO EACH OTHER IN THAT ALL
APPARATUS, MATERIALS, EQUIPMENT, AND METHOD OF INSTALLATION OUTLINED IN THE DRAWINGS AND / OR SPECIFIED HEREIN SHALL BE CONSIDERED ESSENTIAL TO THE CONTRACT. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REVIEW AND COORDINATION OF ALL DRAWINGS PRIOR TO ANY CONSTRUCTION.
2. NEW AND / OR EXISTING EQUIPMENT INDICATED ON THIS DRAWING IS SHOWN IN APPROXIMATE POSITION(S).
THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, INCLUDING EQUIPMENT LOCATIONS, POINTS OF CONNECTION, AND STRUCTURAL MEMBERS, PRIOR TO INSTALLATION. NOTIFY THE CONSTRUCTION COORDINATOR OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO COMMENCING ANY WORK. DO NOT PROCEED WITHOUT CONSTRUCTION COORDINATOR APPROVAL FOR ANY CHANGES REQUIRED.
3. CONTRACTOR SHALL COORDINATE ALL DUCT, PIPE, AND EQUIPMENT LOCATIONS WITH ELECTRICAL, STRUCTURAL, PLUMBING, AND ALL OTHER TRADES.
4. ALL WORK SHALL BE IN ACCORDANCE WITH CITY CODES, STATE OF CALIFORNIA ENERGY CONSERVATION STANDARDS, AND ALL OTHER APPLICABLE CODES.
5. ROOM THERMOSTATS SHALL BE CAPABLE OF BEING SET TO MAINTAIN SPACE TEMPERATURE SET POINTS FROM 55°F TO 85°F, AND BE CAPABLE OF OPERATING THE HEATING AND COOLING IN SEQUENCE.
THERMOSTATS SHALL BE ADJUSTABLE TO PROVIDE A TEMPERATURE RANGE OF UP TO 10°F BETWEEN FULL HEATING AND FULL COOLING BEING SUPPLIED. CONTROLS SHALL HAVE THE CAPABILITY OF TERMINATING ALL HEATING AT A TEMPERATURE NOT MORE THAT 70°F. THERMOSTATS SHALL BE HANDICAP ACCESSIBLE, LOCATED AT 48 INCHES ABOVE FLOOR.
6. ALL DUCTWORK SHALL BE CONSTRUCTED, ERECTED, AND TESTED IN ACCORDANCE WITH THE MOST RESTRICTIVE OF LOCAL REGULATIONS AND PROCEDURES DETAILED IN THE A.S.H.R.A.E. HANDBOOK OF FUNDAMENTALS, OR THE APPLICABLE STANDARDS ADOPTED BY S.M.A.C.N.A.. PROVIDE RECTANGULAR DUCT OF GALVANIZED STEEL AND PREFABRICATED SPIRAL LOCK-SEAM DUCTS AND FITTINGS. ALL DUCT SIZES SHOWN ARE NET INSIDE CLEAR DIMENSIONS (I.E. AFTER INSULATION HAS BEEN INSTALLED, REVIEW PLANS CLOSELY FOR LINED DUCTWORK.)
7. ALL FLEXIBLE DUCT SHALL BE CONSTRUCTED WITH EXTERIOR REINFORCED LAMINATED VAPOR BARRIER, 1- 1/2" THICK FIBERGLASS INSULATION (K-25 AT 75°F), ENCAPSULATED SPRING STEEL WIRE HELIX, AND IMPERVIOUS SMOOTH NON PERFORATED INTERIOR VINYL LINER. INDIVIDUAL LENGTHS OF FLEXIBLE DUCT SHALL BE SUPPORTED AT OR NEAR MID-LENGTH WITH A 2" WIDE 28-GAUGE STEEL HANGER COLLAR.
ATTACHED TO THE STRUCTURE WITH AN APPROVED DUCT HANGER. IN COMPLETE CONFORMANCE WITH 2019 C.M.C. APPENDIX. MAXIMUM LENGTH CONNECTION TO TERMINAL OUTLET SHALL BE 5 FEET.
8. ALL CEILING DIFFUSERS SHALL BE 4-WAY THROW, UNLESS SHOWN OTHERWISE.
9. ALL H.V.A.C. SYSTEMS SHALL MEET THE CONTROL REQUIREMENTS PER SECTIONS 111 AND 122 E.E.S.
10. ALL H.V.A.C. EQUIPMENT AND APPLIANCES SHALL MEET THE REQUIREMENTS PER SECTIONS 111-113, 115 AND 120-129 E.E.S.
11. DO NOT SCALE DRAWINGS - ALL DIMENSIONS AND JOB CONDITIONS SHALL BE VERIFIED BY THE CONTRACTOR AT THE JOB SITE TO BID SUBMITTAL, START OF CONSTRUCT AND / OR FABRICATION OF MATERIALS. IF DISCREPANCIES ARE ENCOUNTERED, THE ENGINEER SHALL BE NOTIFIED FOR CLARIFICATION.
12. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTION AND REPAIR OF ADJACENT EXISTING SURFACES,
EQUIPMENT, AREAS, AND PROPERTY THAT MAY BE DAMAGED AS A RESULT OF ANY DEMOLITION AND / OR NEW WORK.
13. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF THE CEILING DIFFUSERS AND GRILLES.
14. SEE ARCHITECTURAL DRAWINGS FOR ROOF ACCESS AND ADDITIONAL ENERGY CONSERVATION NOTES.
15. SEE PLUMBING DRAWINGS FOR GAS PIPING, PRIMARY AND SECONDARY CONDENSATE PIPING, AND FINAL CONNECTIONS.
16. PROVIDE SEISMIC RESTRAINTS FOR ALL MECHANICAL SYSTEMS PER CODE.
17. ALL PIPING AND DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS OF SECTIONS 118, 123, 123, TITLE 24 ENERGY STANDARDS,A ND TABLE 6-6A AND 6-6B OR C.M.C.
18. INSULATION, ADHESIVES, VAPOR-BARRIER MATERIALS, AND OTHER ACCESSORIES SHALL BE NON- COMBUSTIBLE. THE MATERIALS SHALL HAVE U.L. FLAMESPREAD RATING NOT MORE THAN 25 AND A SMOKE DENSITY NOT MORE THAT 50.
19. ALL SUPPLY, RETURN, OUTSIDE, AND RELIEF BRANCH DUCTS SHALL BE PROVIDED WITH ACCESSIBLE MANUAL VOLUME DAMPERS WITH LOCKS. BRANCHES ABOVE HARD LID CEILINGS SHALL UTILIZE REMOTE VOLUME DAMPERS LOCATED IN ACCESSIBLE AREAS SO TO AVOID ACCESS PANELS.
20. PROVIDE FLEXIBLE CONNECTIONS AT THE INLET AND OUTLET OF ALL FANS.
21. EACH SYSTEM SUPPLYING AIR IN EXCESS OF 2000 CFM SHALL BE EQUIPPED WITH AN AUTOMATIC SHUTOFF.
AUTOMATIC SHUTOFF SHALL SHUT DOWN IN THE SIR-MOVING EQUIPMENT WHEN THE SMOKE IS DETECTED IN THE SUPPLY AIR. DETECTOR SHALL BE INSTALLED IN THE MAIN SUPPLY, AHEAD OF ANY SUPPLY BRANCHES.
SPACES SERVED BY MULTIPLE AIR MOVING SYSTEMS SHALL HAVE INTERLOCKED SMOKE DETECTORS,
CONNECTED TOGETHER THROUGH A RELAY PANEL TO SHUTOFF ALL EQUIPMENT SERVING THE SPACE WHEN SMOKE IS DETECTED BY ANY SINGLE SMOKE DETECTOR.
22. PVC PIPING SHALL NOT BE ALLOWED IN THE BUILDING.
23. FIRE-STOPPING SHALL BE PROVIDED WHERE PENETRATING ITEMS PASS ENTIRELY THROUGH BOTH
PROTECTIVE MEMBRANES OR BEARING WALLS REQUIRED TO HAVE A FIRE RESISTIVE RATING, AND WALL REQUIRING PROTECTED OPENINGS. FIRE-STOPPING SHALL ALSO BE PROVIDED AT PENETRATIONS OF FIRE RESISTIVE FLOORS AND FLOORS WHICH ARE PART OF A CEILING-FLOOR ASSEMBLY. FIRE-STOPPING SHALL HAVE AN "F" OR "T" RATING AS DETERMINES BY TEST CONDUCTED IN ACCORDANCE WITH C.B.C., 2007 EDITION.
24. AIR FILTERS SHALL BE STATE FIRS MARSHALL APPROVED AND LISTED. PRE-FORMED FILTERS HAVING COMBUSTIBLE FRAMING SHALL BE TESTED AS A COMPLETE ASSEMBLY. AIR FILTERS IN ALL OCCUPANCIES SHALL BE CLASS 2 OR BETTER (AS SHOWN IN THE STATE FIR MARSHALL LISTING). AIR FILTERS SHALL BE ACCESSIBLE FOR CLEANING AND / OR REPLACEMENT.
25. ALL SPLIT-SYSTEM AIR CONDITIONING SYSTEMS SHALL HAVE REFRIGERANT LINES SIZED AND INSTALLED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS FOR EACH SYSTEM APPLICATION.
THIS CONTRACT SHALL INCLUDE ALL ACCESSORIES, HARDWARE, ETC. THAT MAY BE RECOMMENDED.
26. OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL BE INSTALLED WITH DAMPERS THAT AUTOMATICALLY CLOSE DURING PERIODS OF NON-USE OF THE AREAS SERVED BY THE EQUIPMENT.
27. PRE-OCCUPANCY VENTILATION SHALL BE: (a) THE MINIMUM RATE OF OUTDOOR AIR REQUIRED BY CALIFORNIA ENERGY EFFICIENCY STANDARDS SECTION 121 (b), OR (b) THREE COMPLETE AIR CHANGES, WHICHEVER IS
LESS, AND SHALL BE SUPPLIED TO THE ENTIRE BUILDING DURING THE ONE-HOUR PERIOD IMMEDIATELY BEFORE THE BUILDING IS NORMALLY OCCUPIED.
28. ALL DAMPERS AND CIRCUIT SETTERS SHALL BE READILY ACCESSIBLE FOR TESTING AND MAINTENANCE, LEFT
OPEN, CHECKED FOR RANGE OF ADJUSTMENT, AND NOT INSULATED OVER UNTIL TEST AND BALANCE IS COMPLETED.
29. CERTIFICATE OF ACCEPTANCE (MECH-1-A) AND ALL RELATED ACCEPTANCE DOCUMENTS SHALL BE SUBMITTED TO THE FIELD INSPECTOR DURING CONSTRUCTION. CERTIFICATE OF OCCUPANCY WILL NOT BE ISSUED UNTIL THESE FORMS ARE REVIEWED AND APPROVED.
30. COMPONENTS THAT ARE INSTALLED IN-LINE WITH THE DUCT SYSTEM AND HAVE AN OPERATING WEIGHT GREATER THEN 75 LBS. SUCH AS FANS, HEAT EXCHANGERS, AND HUMIDIFIERS, SHALL BE SUPPORTED AND LATERALLY BRACED INDEPENDENT OF THE DUCT SYSTEM. (ASCE 7 SEC. 13.6.7)
31. SEISMIC SUPPORTS ARE REQUIRED FOR HVAC DUCTWORK WHERE THE DUCTS ARE SUSPENDED FROM HANGERS MORE THAN 12 INCHES IN LENGTH OR IF THE HVAC DUCTS HAVE A CROSS SECTIONAL AREA OF 6 SQUARE FEET OR GREATER. (ASECE 7 SEC. 13.6.7)
T
S
SD
MECHANICAL LEGEND
SYMBOL ABBREVIATION DESCRIPTION
FD/SFD
VD
MD
MD-NO.)
18"x12"
18"ø
D/L
U/C
SR
FC
TG
FD/SFD
VD
MD
MDFA
AD/AP
D/L
U/C
POC
MECHANICAL LEGEND (CONTINUED)
SYMBOL ABBREVIATION DESCRIPTION
RELIEF VALVE [DIAGRAMMATIC]
MAKE-UP WATER VALVE [DIAGRAMMATIC]
GATE VALVE [DIAGRAMMATIC]
FLEXIBLE PIPE CONNECTOR [DIAGRAMMATIC]
DRAIN VALVE WITH HOSE BIBB [DIAGRAMMATIC]
PRESSURE GAUGE WITH BALL VALVE [DIAGRAMMATIC]
SOLENOID VALVE
THERMOMETER [DIAGRAMMATIC]
PETE'S PLUG [DIAGRAMMATIC]
MECHANICAL COUPLING [DIAGRAMMATIC]
MANUAL AIR VENT [DIAGRAMMATIC]
PUMP SUCTION DIFFUSER [DIAGRAMMATIC]
DIFFUSER / GRILLE CALLOUT
CFM
AFF
AMB
CFM
DB
DIA
E)
EF
ESP
F
FLA
FPM
GAL
GPM
H2O
HP
KW
LBS
MAX
MBH
MIN
OA
OBD
OV
PD
RPM
SQ. FT.
TONS
TSP
VEL
WB
ABOVE FINISHED FLOOR
AMBIENT
CUBIC FEET PER MINUTE
DRY BULB
DIAMETER
EXISTING
EXHAUST FAN
EXTERNAL STATIC PRESSURE (INCHES OF WATER)
DEGREES FAHRENHEIT
FULL LOAD AMPERES
FEET PER MINUTE
GALLON
GALLONS PER MINUTE
WATER
HORSE POWER
KILOWATTS
POUNDS (WEIGHT)
MAXIMUM
CAPACITY EXPRESSED IN THOUSANDS OF BTU/HR
MINIMUM
OUTSIDE AIR
OPPOSED BLADE DAMPER
OUTLET VELOCITY
PRESSURE DROP (FEET OF WATER)
REVOLUTIONS PER MINUTE
SQUARE FEET
CAPACITY IN TONS OF REFRIGERATION
TOTAL STATIC PRESSURE (INCHES OF WATER)
VELOCITY
WET BULB
DUCTWORK
LINED DUCTWORK
FLEXIBLE DUCTWORK
SUPPLY DIFFUSER
RETURN AIR REGISTER
EXHAUST AIR GRILLE
SUPPLY DUCT SECTION
RETURN DUCT SECTION
EXHAUST DUCT SECTION
ROUND DUCT SECTION
SIDEWALL REGISTER
LINEAR SLOT SUPPLY DIFFUSER
LINEAR SLOT RETURN AIR (DUCTED AND NON-DUCTED)
FLEXIBLE CONNECTION
TRANSFER AIR GRILLE BOOT ASSEMBLY
FIRE DAMPER OR SMOKE / FIRE DAMPER [DIAGRAMMATIC]
VOLUME DAMPER
MOTORIZED CONTROL DAMPER
MOTORIZED DAMPER FIRE ALARM
RECTANGULAR DUCTWORK (DOUBLE LINE)
FIRST NUMBER INDICATES SIDE SHOWN
ROUND DUCTWORK (DOUBLE LINE)
SMOOTH RADIUS DUCT ELBOW WITHOUT TURNING VANES
RECTANGULAR 90° ELBOW WITH AIRFOIL TURNING VANES
ACCESS DOOR / ACCESS PANEL
DOOR LOUVER (INDICATED FREE AREA)
UNDERCUT DOOR (INDICATED AFF CLEARANCE)
POINT OF CONNECTION
SMOKE DETECTOR
THERMOSTAT
SENSOR
PIPE UP
PIPE DOWN
PIPE DROP / PIPE RISE
TOP CONNECTION BRANCH LINE
BOTTOM CONNECTION BRANCH LINE
TEE UP
TEE DOWN
S
ALL MECHANICAL AND ELECTRICAL EQUIPMENT SHALL BE BRACED OR ANCHORED TO RESIST A HORIZONTAL FORCE ACTING IN ANY DIRECTION USING THE FOLLOWING CRITERIA:
EQUIPMENT ON STRUCTURE: 30% OF OPERATING WEIGHT
EQUIPMENT ON GRADE: 20% OF OPERATING WEIGHT
FOR FLEXIBLE MOUNTING EQUIPMENT, USE 2 X THE ABOVE RULES, AND FOR SIMULTANEOUS VERTICAL FOR USE ø X THE HORIZONTAL FORCE.
THE ABOVE VALUES ARE FOR AN IMPORTANCE FACTOR, "I" = 1.10 AND SEISMIC ZONE, "Z" = 0.4.
WHERE ANCHORAGE DETAILS ARE NOT SHOWN ON THE DRAWINGS, THE FIELD INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE STRUCTURAL ENGINEER.
SEISMIC REQUIREMENTS
ENERGY CONSERVATION NOTES
1. INSULATION MATERIAL SHALL MEET THE CALIFORNIA QUALITY STANDARD PER SECTION 118 E.E.S.
2. 3.
4. 5.
DOORS AND WINDOWS SHALL MEET THE MINIMUM INFILTRATION REQUIREMENTS PER SECTION 116 E.E.S.
ALL PIPING AND DUCTWORK SHALL BE INSULATED CONSISTENT WITH THE REQUIREMENTS OF SECTIONS 118, 123, AND 124 E.E.S., TABLE 6-D, AND SECTION 120 U.M.C.
ALL HVAC SYSTEMS SHALL MEET THE CONTROL REQUIREMENTS PER SECTIONS 112 AND 122 E.E.S.
ALL HVAC EQUIPMENT AND APPLIANCES SHALL BE THE REQUIREMENTS PER SECTIONS 111-113, 115, AND 120- 129 E.E.S.
MECHANICAL GENERAL NOTES AND LEGEND
MECHANICAL SCHEDULES
MECHANICAL SCHEDULES
MECHANICAL THERMAL ZONING PLAN
MECHANICAL FLOOR PLAN
MECHANICAL PIPING FLOOR PLAN
MECHANICAL ROOF PLAN
MECHANICAL DETAILS
MECHANICAL DETAILS
MECHANICAL DETAILS
MECHANICAL CONTROL DIAGRAMS
TITLE 24 DOCUMENTATION
SHEET INDEX
M0.1
M0.2
M0.3
M1.1
M2.1
M2.2
M2.3
M3.1
M3.2
M3.3
M4.1
M5.1
CAL GREEN NOTES
1. 5.201.1 SCOPE. THE CALIFORNIA ENERGY COMMISSION WILL CONTINUE TO ADOPT MANDATORY BUILDING STANDARDS.
2. 5.410.2 COMMISSIONING FOR NEW BUILDINGS 10,000 SQUARE FEET AND OVER, BUILDING COMMISSIONING SYSTEMS BY TITLE 24 DOCUMENTATION, PART 6, PROCESS SYSTEMS AND RENEWABLE ENERGY SYSTEMS SHALL BE INCLUDED IN THE DESIGN AND CONSTRUCTION PROCESSES OF THE BUILDING PROJECT. COMMISSIONING REQUIREMENTS SHALL INCLUDE ITEMS LISTED IN SECTION 5.410.2.
3. COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION OR DURING STORAGE ON THE
CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT OPENINGS SHALL BE
COVERED WITH TAPE, PLASTIC, SHEET METAL, OR OTHER METHODS ACCEPTABLE TO ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST OR DEBRIS WHICH MAY COLLECT IN THE SYSTEM. COVERING OF DUCT OPENINGS AND PROTECTION OF MECHANICAL EQUIPMENT DURING CONSTRUCTION. AT THE TIME OF ROUGH INSTALLATION OR DURING
STORAGE ON THE CONSTRUCTION SITE AND UNTIL FINAL STARTUP OF THE HEATING AND COOLING EQUIPMENT, ALL DUCT AND OTHER RELATED AIR DISTRIBUTION COMPONENT
OPENINGS SHALL BE COVERED WITH TAPE, PLASTIC, SHEET METAL, OR OTHER METHODS ACCEPTABLE TO ENFORCING AGENCY TO REDUCE THE AMOUNT OF DUST OR DEBRIS WHICH MAY COLLECT IN THE SYSTEM.
4. 5.504.5.3 FILTERS. IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED AREAS OF THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR PRIOR TO OCCUPANCY THAT PROVIDES AT LEAST A MERV OF 8. A5.504.5.3.1 FILTERS. IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE REGULARLY OCCUPIED AREA OF THE BUILDING WITH AIR FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR PRIOR TO OCCUPANCY THAT PROVIDES AT LEAST A MERV 11.
5. 5506.1 OUTSIDE AIR DELIVERY. FOR MECHANICALLY OR NATURALLY VENTILATED SPACES IN BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF SECTION 121 OF THE CALIFORNIA ENERGY CODE, CCR, TITLE 24, PART 6 , AND CHAPTER 4 OR CCR, TITLE 8 OR THE APPLICABLE LOCAL CODE, WHICHEVER IS MORE STRINGENT. AT THAN 1.
6. 5.506.2 CARBON DIOXIDE (CO2) MONITORING. FOR BUILDINGS EQUIPPED WITH DEMAND CONTROL VENTILATION, CO2 SENSORS AND VENTILATION CONTROLS SHALL BE SPECIFIED AND INSTALLED IN ACCORDANCE WITH THE REQUIREMENTS OF THE LATEST EDITION OF THE CALIFORNIA ENERGY CODE, C.C.R., TITLE 24, PART 6, SECTION 121 (C).
7. 5.508.1 OZONE DEPLETION AND GLOBAL WARMING REDUCTIONS. INSTALLATION OF HVAC, REFRIGERATION AND FIRE SUPPRESSION OF EQUIPMENT SHALL COMPLY WITH SECTION
5.508.1.1 AND 5.508.1.2 CFCS. INSTALL HVAC AND REFRIGERATION EQUIPMENT THAT DOES NOT CONTAIN CFCS. 508.1.2 HALONS. INSTALL FIRE SUPPRESSION EQUIPMENT THAT DOES NOT CONTAIN HCFCS. A5.508.1.4 HYDROFLUOROCARBONS (HFCS). INSTALL HVAC COMPLYING WITH EITHER OF THE FOLLOWING:
A. INSTALL HVAC, REFRIGERATION, AND FIRE SUPPRESSION EQUIPMENT THAT DOES NOT CONTAIN HFCS OR THAT DO NOT CONTAIN HFCS WITH A GLOBAL WARMING POTENTIAL GREATER THAN 150.
B. INSTALL HVAC AND REFRIGERANT EQUIPMENT THAT LIMIT THE USE OF HFC REFRIGERANT THROUGH USE OF A SECONDARY HEAT TRANSFER FLUID WITH A GLOBAL WARMING POTENTIAL NO GREAT THAN 1.
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
GENERAL
NOTES AND
LEGEND
200102
M0.1
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 286 of 357
WEIGHTMODELNO.MANUFACTURERMARK LOCATION AREA SERVED
PACKAGED ROOFTOP VAV SCHEDULE
FLA
FAN
CONDCFMMIN. O.A.
H O)2
COMP.(IN.
SP
EXT.
FLA
ELECTRICAL
HP FLA
EVAPCOND
FAN FAN PH.VOLT CYCLE
SENS.
MAX.
FUSEMCA (MBH)
CAP.ENT. DB
F)
COOLING
CAP.
F)
ENT. WB
E.E.R.
AMB.
F)(LBS.)
OPER.
REMARKS
DAIKIN MPS026G ROOF ALL VAV ZONES 10,000 4,000 1.5 (3)12.2 (3)2.0 -13.0 5.6 208 3 60 134.3 150 297.4 236.4 80 67 95 11.0 6,050 PROVIDE WITH VIBROACOUSTICS INTEGRAL VIBRATION ISOLATION SOUND ATTENUATION CURB, TYPE NCC-VCR. PROVIDE WITH SUPPLY AIR SMOKE DETECTOR, MERV 13 FILTERS, AND EPOXY COATING ON COOLING COIL. SHALL BE PROVIDED WITH INTEGRAL VFD AND MODULATING POWER EXHAUST. UNIT SHALL BE CONTROLLED THROUGH BMS, PROVIDE WITH BACNET INTERFACE.
BHP
EVAP
FAN
RTU
1 PROVIDE 115 V, 3/4 HP, 10.8 AMPS, RECIRCULATION PUMP AND FLUE CONNECTION. NON-CONDENSING BOILER, 84% EFF. PROVIDE WITH COLD START KIT. PROVIDE WITH OUTDOOR VENT CAP. PROVIDE WITH COMMUNICATIONS GATEWAY-BACNET.
RAYPAK
HI-DELTA
302C
ROOF HEATING HOT WATER 25 160 180 1.0 300 252 115 1 60 500 MANUFACTURERMARK MODEL NO.
HEATING HOT WATER BOILER SCHEDULE
REMARKS
ELECTRICAL
VOLTCYCLELOCATIONGPMSERVED
SYSTEM
MBH)
INPUT
RATING
MBH)
OUTPUT
RATING
PH.(LBS.)
OPER.
WEIGHTPDFT.)TEMP
ENT
TEMP
LVG
F) (° F)
B
1 MANUFACTURERMARK MODEL NO.
PUMP SCHEDULE
REMARKS
OPER.
WEIGHT
LBS.)
PUMP MOTOR
GPM
HEAD
FT. H O)
SYSTEM
SERVED
ARMSTRONG LEAD PUMP. INTEGRATED INTELLIGENT VARIABLE SPEED SENSORLESS CONTROL. PROVIDE WITH PUMP STANCHIONS.
LOCATION IMPELLER DIA. TYPE
2 RPM
HP / BHP VOLT PH.CYCLE(
FT. H O)
MIN. NPSH
2 4380 DE SENSORLESS
0103-000.7
ROOF
HEATING HOT
WATER
3.05" IN-LINE 25 50 27.7 4091 1.5 / 0.54 208 3 60 60
MAX.
SIZE
ARMSTRONG LAG PUMP (100% BACK UP). INTEGRATED INTELLIGENT VARIABLE SPEED SENSORLESS CONTROL. PROVIDE WITH PUMP STANCHIONS.
ROOFP
2 P
1 4380 DE SENSORLESS
0103-000.7
3.05" IN-LINE 25 208 3 6060HEATINGHOT
WATER
50 27.7 4091 1.5 / 0.54
AIR SEPARATOR SCHEDULE
MANUFACTURERMARK MODEL NO.
SPIROTHERM
SERVICE GPM REMARKS
LBS.)
WEIGHT
OPER.
VJR-150TM
HEATING HOT
WATER
25 1.5 2.6 x 9.1 15 BRASS JUNIOR MICROBUBBLE ELIMINATOR.
INLET
SIZE
INCHES)
DIMENSIONS
DIA. x HEIGHT)
INCHES)
1 FT.)
P.D.
MAXIMUM
AS
1 MANUFACTURERMARK MODEL NO.
EXPANSION TANK SCHEDULE
REMARKSSYSTEMSERVEDLOCATION
SIZE
DIA. X
LENGTH)(
GALS.)
CAP.
LBS.)
WEIGHT
OPER.
PRESSURIZED
ARMSTRONG 130-L ROOF 12 PSI HEATING HOT WATER 20 x 37 35 420 BLADDER EXPANSION TANK, ALLOW 18" CLEARANCE FOR SYSTEM. MANUFACTURER SHALL PROVIDE MOUNTING CLIPS FOR EXPANSION TANK FLOOR MOUNTING. PROVIDE EQUIPMENT MOUNTING PAD, SIZE PER MANUFACTURER RECOMMENDATION.
ET
1 MANUFACTURERMARK MODEL NO.
VARIABLE AIR VOLUME TERMINAL SCHEDULE
REMARKS
OPER.
WEIGHT
LBS.)
AREA
SERVEDLOCATION
SIZE
INLET)
MIN. OR
HEATING
CFM (°F)
WTR.
HEATING COIL
LVG.
GPMHTG.
MBH
CONN.
SIZE
ENT.
WTR.
F)
ENT.
AIR
F)
LVG.
F)
AIR ROWS
VALVE
TYPE
TITUS
MIN. S.P.
W.C.)
DESV CEILING ZONE 1 10 0.238 800 25.2 2.5 2 3/4" 2-WAY 40 PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.180 160 55 81.4800 MAX.
CFM
VAV
1 8 0.388 630 21.4 2.13586.2630
10 290 17.5 1.8110.6750
12 0.266 370 22.2 2.250110.11,100
0.207 100 5.9 0.630109.1300
170 10.2 1.0109.9430
0.207 130 7.8 0.8110.1300
0.150 280 16.7 1.7109.9900
10 0.238 200 11.9 1.2109.5790
8 0.388 150 9.0 0.9109.9620
8 0.388
8 0.097 70 4.1 0.5108.9350
VAV
2 VAV
3 VAV
4 VAV
5 VAV
6 VAV
7 VAV
8 VAV
9 VAV
10 VAV
11 VAV
12 6 0.092 30 1.6 0.5102.3150
VAV
13 VAV
14 TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
TITUS DESV
CEILING ZONE 2
CEILING ZONE 3
CEILING ZONE 4
CEILING ZONE 5
CEILING ZONE 6
CEILING ZONE 7
CEILING ZONE 8
CEILING ZONE 9
CEILING ZONE 10
CEILING ZONE 11
CEILING ZONE 12
CEILING ZONE 13
CEILING ZONE 14
6 8
12 6
180 160
180 160
180 160
180 160
180 160
180 160
180 160
180 160
180 160
180 160
180 160
180 160
55 55
55 55
55 55
55 55
55 55
55 55
2 3/4" 3-WAY
2 3/4" 2-WAY
2 3/4" 2-WAY
2 3/4" 2-WAY
2 3/4" 2-WAY
2 3/4" 3-WAY
2 3/4" 2-WAY
2 3/4" 2-WAY
2 3/4" 2-WAY
2 3/4" 2-WAY
2 3/4" 3-WAY
2 3/4" 3-WAY
40 30
40 35
40 35
30 35
35 VAV
15 VAV
16 VAV
17 TITUS DESV CEILING
TITUS DESV CEILING
TITUS DESV CEILING 8 0.198 210 12.5 1.3109.8590180 160 55 2 3/4" 2-WAY 35 6 0.207 160 9.5 1.0109.3300180 160 55 2 3/4" 2-WAY 30
14 0.243 490 29.3 2.9110.11,470 180 160 55 2 3/4" 2-WAY50ZONE15 ZONE 16
ZONE 17
390 23.2 2.3109.97401018016055 2 3/4" 2-WAY 40
150 9.0 0.9109.9620
0.238
0.388
0.238
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
PROVIDE WITH THERMOSTAT CONNECTED TO DDC CONTROL SYSTEM.
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
SCHEDULES
200102
M0.2
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
NOTE: PROVIDE ONE (1) 120V TO 24V TRANSFORMER FOR EVERY FIVE (5) VAV BOXES.
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 287 of 357
PROVIDE WITH MANUFACTURER ROOF CURB AND BACKDRAFT DAMPER. FAN SHALL BE CONTROLLED BY THERMOSTAT SET TO 80 DEG. F, ADJUSTABLE.
MONITOR THRU BMS.
GREENHECK GB-081-6 ROOF ELECTRICAL ROOM BELT 250 0.25 11.188 855 115 1 60 75- 1/6
MANUFACTURERMARK MODEL NO.
EXHAUST FAN SCHEDULE
REMARKSAREASERVEDLOCATIONTYPECFM
SP
IN.
H O)
FAN
SIZE
IN.)
FAN RPM
HP
WATTS VOLT
ELECTRICAL
CYCLEPH.
OPER.
WEIGHT
LBS.)2
EF
1 dBA
SONES
43 3.4
GB-141-5
MEN'S LOCKER
ROOM
1,500 0.5 14.625 1,083 100-
1/2 57
8.7 GB-071-6 WASH ROOM 150 0.25 1,018 75-
1/6 45
4.0 GB-101-4
WOMEN'S LOCKER
ROOM
900 0.5 11.125 1,397 75-
1/4 56
7.7 FITNESS 350 0.5 1,206 75-
1/6 51
6.0 BREAK / COPY 250 0.5 1,567 75-
1/6 57
8.6 RESTROOM 150 0.5 1,242 75-
50 5.7
EF
2 EF
3 EF
4 EF
5 EF
6 EF
7 GREENHECK
GREENHECK
GREENHECK
GREENHECK
GREENHECK
GREENHECK
ROOF
ROOF
ROOF
ROOF
ROOF
ROOF
75-
50 5.7
EF
8 GREENHECK ROOF
BELT
BELT
BELT
BELT
BELT
BELT
BELT
115 1 60
115 1 60
115 1 60
115 1 60
115 1 60
115 1 60
115 1 60
GB-081-6
GB-071-6
GB-071-6
GB-071-6 RESTROOM 150 0.5 1,242
1/6
1/6
PROVIDE WITH MANUFACTURER ROOF CURB AND BACKDRAFT DAMPER. FAN SHALL BE CONTROLLED BY LIGHT SWITCH. MONITOR THRU BMS.
PROVIDE WITH MANUFACTURER ROOF CURB AND BACKDRAFT DAMPER. FAN SHALL BE CONTROLLED BY LIGHT SWITCH. MONITOR THRU BMS.
PROVIDE WITH MANUFACTURER ROOF CURB AND BACKDRAFT DAMPER. FAN SHALL BE CONTROLLED BY BMS TO OPERATE DURING HOURS OF OPERATION.
PROVIDE WITH MANUFACTURER ROOF CURB AND BACKDRAFT DAMPER. FAN SHALL BE CONTROLLED BY BMS TO OPERATE DURING HOURS OF OPERATION.
PROVIDE WITH MANUFACTURER ROOF CURB AND BACKDRAFT DAMPER. FAN SHALL BE CONTROLLED BY BMS TO OPERATE DURING HOURS OF OPERATION.
PROVIDE WITH MANUFACTURER ROOF CURB AND BACKDRAFT DAMPER. FAN SHALL BE CONTROLLED BY BMS TO OPERATE DURING HOURS OF OPERATION.
PROVIDE WITH MANUFACTURER ROOF CURB AND BACKDRAFT DAMPER. FAN SHALL BE CONTROLLED BY BMS TO OPERATE DURING HOURS OF OPERATION.
11.188
11.188
11.188
11.188
11.188
AREASERVEDMARKMANUFACTURER
VIBROACOUSTICS
LOCATION
RTU-1
SUPPLY
MODEL NO.
EXRD-HV-F3 300
LBS.)
WEIGHT
UNIT.
SOUND ATTENUATOR SCHEDULE
DYNAMIC INSERTION LOSS IN OCTAVE BAN (db)
A.P.D.
IN. W.G.)
MAX.
0.18 MAX.)
10,000
CFM
DIM.
OVERALL
120 x 40 x 20
125
15 1000250
28 500
4040
40002000
26 17
REMARKS
RTU-1
SUPPLY
LxWxH (IN.)
EXRD = EXTENDED RECTANGULAR DISSIPATIVE.
SA
1 RED-MHV-FJ 9500.097,000 84 x 60 x 24 28 29 4331 3227SA 2 VIBROACOUSTICS RTU-1
RETURN
RTU-1
RETURN
RED = RECTANGULAR ELBOW DISSIPATIVE. FINAL ELBOW HEIGHT SHALL BE FIELD COORDINATED.
SPLIT SYSTEM HEAT PUMP / CONDENSING UNIT SCHEDULE (COOLING ONLY) WEIGHTMODELNO.MANUFACTURERMARK LOCATION
SERVED
AREA
FLA
FANCONDCFMO.A.
MIN.
COMP.
FLA
FAN
ELECTRICAL
FLA HP
EVAPEVAP
FAN FAN
WATTS
PH.VOLT CYCLE
SENS.
MAX.
FUSEMCA (MBH)
CAP. ENT. DB
F)
COOLING
CAP.
F)
ENT. WB
S.E.E.R.
AMB.
F)(LBS.)
OPER.
REMARKS
FTX36DAIKIN SERVER ROOM SERVER ROOM 740 - - - -0.37 -64 208 1 60 -- - - 80 67 -- 50 RX36DAIKIN ROOF FC-1 - - - -0.83 --123 19.8 20 34.4 22.2 - - 95 15.9 150 PROVIDE WITH EQUIPMENT MOUNTING PAD, SIZE PER MANUFACTURER RECOMMENDATION.
PROVIDE NEOPRENE PADS FOR VIBRATION ISOLATION.
EXT. SP
IN. WC)
SPACE IS UNOCCUPIED, OUTSIDE AIR IS NOT REQUIRED. POWERED THRU OUTDOOR CONDENSING UNIT. PROVIDE WITH INTEGRAL CONDENSATE PUMP AND WIRED CONTROLLER.
PROVIDE ROOM TEMPERATURE SENSOR TO INTERFACE WITH BMS.
FC
1 CU
1 208 1 60
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
SCHEDULES
200102
M0.3
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 288 of 357
ZONE 13
140 SQFT
ZONE 11
350 SQFT
ZONE 15
2,020 SQFT
ZONE 10
290 SQFT
T
T
T
ZONE FC-1
100 SQFT
T
ZONE 1
1,180 SQFT
T
ZONE 2
840 SQFT
T
ZONE 3
700 SQFT
ZONE 4
470 SQFT
T
T
T
ZONE 5
330 SQFT
ZONE 6
350 SQFT
T
ZONE 8
340 SQFT
T
T
ZONE 17
855 SQFT
ZONE 9
520SQFTT
T
ZONE 16
220 SQFT
T
ZONE 7
230 SQFT
T
T
ZONE 12
350 SQFT
ZONE 14
120 SQFT
T
T
1 2
G
E
J
F
H
3 C
A
98764101
B
5 D
OPEN WORK
STATIONS
117
STORAGE
114
COPY/MAIL
ROOM
115
RECEIVING
116
OFFICE D1
119MEN'S LOCKER
130
HALL
122
WOMEN'S
128
FITNESS
126
BREAK ROOM
125
OFFICE D1
111
HALL
102
RESTROOM
104
RECEPTION
103
MULTI-PURPOSE
112
OFFICE E1
139
OFFICE E1
138
OFFICE E1
137
OFFICE E1
136
OFFICE E1
135
OFFICE E1
134
OFFICE D1
121
OFFICE C1
109
OFFICE C1
108 OFFICE B
107
CONFERENCE
106
LOBBY
100
RESTROOM
101
OFFICE C1
110
SERVER
118
MEN'S
129
OFFICE E1
140
STORAGE
123JAN
124
OFFICE D1
120
WASH ROOM
131
HWH
127
COPY
105
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/02/20
BLDG DEPT
RESUBMITTAL
BID SET
11/25/20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
THERMAL
ZONING PLAN
200102
M1.1
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE: 1/8" = 1'-0"M1.1
1 MECHANICAL ZONING PLAN
KEYNOTES
GENERAL NOTES
1 ELECTRICAL ROOM IS VENTILATED ONLY.
1.FOR THERMOSTAT MOUNTING DETAIL, SEE 2/M3.3.
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 289 of 357
11 VAV
13 VAV
1 VAV
2 VAV
3 VAV
4 VAV
5 VAV
7 VAV
17 VAV
16 VAV
8 VAV
9 VAV
15 VAV
10 VAV
18"x16"
40"x20"
24 x1
8 8"ø
10"ø
10"ø 8"ø
10"ø
10"ø
12"ø
16"ø
14"ø
10"ø
14"ø
10"ø
1 FC
C 220
C 210
C 300
CC --CC --
CC --
FF --
C 230
500
CC --
BB 150
C 275
FF --
C 205
CC --
C 300
C 370
C 370
EE --
D 420
C 300
C 300
B 200
B 150
FF --
B 150
C 230
M 550
M 550
B 150
B 150
BB --
BB --
C 230
FF --
B 130
K 350
TYPx2)
BB 100
EE 700
6"ø
8"ø
6"ø
10"ø
8"ø
8"ø
10"ø
16 ø
8"ø
14 ø
16"ø
8"ø
10"ø10"ø
8"ø
10"ø
8"ø
8"ø
10"ø
8"ø
8"ø
8"ø
8"ø
10"ø
10"ø
8"ø
8"ø10"ø
6"ø
10"ø
10"ø
10"ø
12"ø
10"ø
10"ø
10"ø
8"ø10"ø
BREAK ROOM
125
LOBBY
100
SERVER
118
OFFICE D1
119
OFFICE D1
120
MULTI-PURPOSE
112
RECEPTION
103
STORAGE
114
RECEIVING
116
OPEN WORK
STATIONS
117
COPY/MAIL
ROOM
115
WOMEN'S
128
OFFICE B
107
HALL
102
RESTROOM
104
CONFERENCE
106
RESTROOM
101
COPY
105
HWH
127
ELECTRICAL
132
MEN'S
129
OFFICE D1
121
MEN'S LOCKER
130
WASH ROOM
131
STORAGE
123
HALL
122
FITNESS
126
JAN
124
OFFICE D1
111
OFFICE C1
108
OFFICE C1
110
OFFICE C1
109
STORAGE
113
FR
133
8"ø
10"ø
14"ø
BB 150
BB 150
BB 90
10"ø
CC 315 CC 315
6"ø
14"ø
EE --
BB 150
B 100
BB 195
BB 195
3"ø
AA 50
10"ø
CC --
CC --
60"x24"
CC --
FF --
10"ø
FF --
FF --
FF --
16"ø GG --
18"x12"
CC --
12"ø
8"ø
10"ø
8"ø
10"ø
8"ø
12"ø
HH --
24"x14"
FF --
BB --
GG --
18"x12"
II 200
II 350
JJ 990
FF --
FF --
6 VAV
24 x1
8 8"ø
10"ø
10"ø
12 VAV
BB --
B 150
OFFICE E1
139
OFFICE E1
138
OFFICE E1
137
OFFICE E1
136
OFFICE E1
135
OFFICE E1
134
SA
1 SA
2 14
VAV
8"ø
8"ø 8"ø
C 350
CC --
10"ø
14"ø
10"ø 10"ø
OFFICE E1
140
1 15
2 3
3 3
4 510"ø
6 6
2 G
E
J
F
H
3 C
A
98764101
B
5 D
C 365
C 365 C 370
C 370
C 370
10"Ø EA UP
TO EF-1
18"x18" EA
UP TO EF-2
8"Ø EA UP
TO EF-3
16"Ø EA UP
TO EF-4
FF --
10"Ø EA UP
TO EF-5
7 8 9
10"ø
10 11
KK --KK --KK --
KK --
KK --
GG --
GG --
12 2
14"ø
LL 75
LL 90
AA 75
13 13
LL 100
6"ø
8"ø
8"ø
10"ø10"ø
3 10"ø
KK --
10"ø10"ø 10"ø
3 TYPx2)
3 14
3 C 210 C 205 C 205 C 205 C 205 C 210
CC --CC --
CC --
CC --CC --CC --
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSNAL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
FLOOR PLAN
200102
M2.1
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:1/8" = 1'-0"M2.1
1 MECHANICAL FLOOR PLAN
KEYNOTES
GENERAL NOTES
1 PROVIDE 30"x30" ACCESS PANEL.
PROVIDE DOOR LOUVER WITH A MINIMUM OF 0.5 SQFT FREE AREA.
COORDINATE DIMENSIONS WITH ARCHITECTURAL.
RETURN AIR FLEX TAIL. TYPICAL FOR ALL RETURN GRILLES.
3" WATER HEATER FLUE UP TO TERMINATION ON ROOF. CONFIRM SIZING PER MANUFACTURER RECOMMENDATION.
10" COMBUSTION AIR DUCT UP TO ROOF. DUCT INSIDE OF HWH ROOM 127 SHALL TERMINATE WITHIN 12" OF THE CEILING. COVER WITH WIRE MESH SCREEN.
PROVIDE 1" ACOUSTICAL DUCT LINING.
12"x12" UP TO EF-6.
8" UP TO EF-7.
8" UP TO EF-8.
4" DRYER EXHAUST DUCT DOWN TO FUTURE DRYER VENT LOCATION. 4" DRYER EXHAUST DUCT UP TO VENT CAP ON ROOF.
PROVIDE DUCTWORK WITH 1" INTERNAL LINING.
ALL EXHAUST DUCTWORK SERVING LOCKER/SHOWER AREAS SHALL BE STAINLESS STEEL.
DUCTWORK SHALL BE INSTALLED TIGHT TO STRUCTURE.
PROVIDE 3/4" DOOR UNDERCUT.
2 3
ALL SIDEWALL GRILLES SHALL BE INSTALLED AS HIGH AS POSSIBLE ON VERTICAL WALLS TO MINIMIZE SIGHT.
FOR VAV BOX INSTALLATION DETAIL, SEE 1/M3.1.
FOR DUCTLESS FAN COIL UNIT MOUNTING DETAIL, SEE 4/M3.1.
FOR TYPICAL DIFFUSER DETAIL, SEE 9/M3.1.
FOR TYPICAL RETURN AIR GRILLE WITH FLEX TAIL DETAIL, SEE 1/M3.2.
FOR EXPOSED DUCTWORK DIFFUSER DETAIL, SEE 2/M3.2.
FOR TYPICAL TRANSFER AIR DETAIL, SEE 3/M3.2.
FOR TYPICAL DUCT TAKEOFFS, SEE 4/M3.2.
FOR TYPICAL DUCT SUPPORT DETAIL, SEE 5/M3.2.
FOR DUCT LINER DETAIL, SEE 6/M3.2.
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
4 5
6 7
8 9
10 11
12 13
14 15
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 290 of 357
VAV-11
VAV-13
VAV-1
VAV-2
VAV-3
VAV-4
VAV-5
VAV-7
VAV-17
VAV-16
VAV-8
VAV-9
VAV-15
VAV-10
FC-1
BREAK ROOM
125
LOBBY
100
SERVER
118
OFFICE D1
119
OFFICE D1
120
MULTI-PURPOSE
112
RECEPTION
103
STORAGE
114
RECEIVING
116
OPEN WORK
STATIONS
117
COPY/MAIL
ROOM
115
WOMEN'S
128
OFFICE B
107
HALL
102
RESTROOM
104
CONFERENCE
106
RESTROOM
101
COPY
105
HWH
127
ELECTRICAL
132
MEN'S
129
OFFICE D1
121
MEN'S LOCKER
130
WASH ROOM
131
STORAGE
123
HALL
122
FITNESS
126
JAN
124
OFFICE D1
111
OFFICE C1
108
OFFICE C1
110
OFFICE C1
109
STORAGE
113
FR
133
3/ 4"3/4"
3/4"3/4"
3/ 4"3/ 4"
3/ 4"3/ 4"
3/ 4"3/4"
1 1/2"1 1/2"
1"1"
3/4"3/4"3/ 4"3/ 4"
3/ 4"3/ 4"
3/4"3/ 4"
3/ 4"3/ 4"
3/4"3/ 4"
1 1/2", UP
2.1 GPM
1 1/ 4"
2.5 GPM
0.5 GPM
0.5 GPM
1.8 GPM
0.6 GPM
2.2 GPM
1.0 GPM
0.8 GPM
1.3 GPM
2.3 GPM
1.7 GPM
2.9 GPM
1.2 GPM
1"1"
3/ 4"3/ 4"
3/4"3/ 4"
VAV-6
1.0 GPM
VAV-14
VAV-12
0.9 GPM 0.9 GPM
3/4"3/4"
1 1/ 4"1 1/ 4"
3/ 4"3/ 4"
1 1/4"1 1/4"
1 1/ 4"1"1"1"1"
3/4"3/4"
3/4"3/4"
3/ 4"3/ 4"
3/ 4"3/ 4"
3/4"3/4"
1 2
G
E
J
F
H
3 C
A
98764101
B
5 D
OFFICE E1
134
OFFICE E1
135
OFFICE E1
136
OFFICE E1
137
OFFICE E1
138
OFFICE E1
139
OFFICE E1
140
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
PIPING FLOOR
PLAN
200102
M2.2
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE: 1/ 8" = 1'-0"M2.2
1 MECHANICAL PIPING FLOOR PLAN
KEYNOTES
GENERAL NOTES
1 REFRIGERANT PIPING UP TO CONDENSING UNIT ON ROOF.
FOR VAV BOX REHEAT COIL PIPING DIAGRAM, SEE 3/M3.1.
FOR DUCTLESS FAN COIL UNIT MOUNTING DETAIL, SEE 4/M3.1.
FOR VERTICAL DX PIPE SUPPORT DETAIL, SEE 8/M3.2.
FOR TYPICAL PIPE SUPPORT DETAIL, SEE 9/M3.2.
1. 2.
3. 4.
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 291 of 357
1 EF
2 EF
3 EF
4 EF
5 EF
6 EF
7 EF
8 EF
10' - 0"
10' - 0"
10' - 0"
10' - 0"
10' -
0"
10 0"
10' -
0"
1 B
1 CU
1 P
2 P
1 RTU11/2", DN
1 ET
1 AS
1 1/ 2"1 1/ 2"
2 G
E
J
F
H
3 C
A
98764101
B
5 D
1 2
3 10"ø
4 5
5 6
10' -
0"
6 10' -
0"
6 6
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
ROOF PLAN
200102
M2.3
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE: 1/8" = 1'-0"M2.3
1 MECHANICAL ROOF PLAN
KEYNOTES
GENERAL NOTES
1 DRYER EXHAUST VENT CAP.
WATER HEATER FLUE VENT CAP.
COMBUSTION AIR INTAKE. TERMINATE AT 45 DEGREE ANGLE WITH OPENING FACING DOWNWARD AND COVER WITH 1/4" WIRE MESH SCREEN.
TERMINATION SHALL NOT BE LESS THAN 12" ABOVE ROOF.
PERMANENT ROOF ACCESS.
MECHANICAL EQUIPMENT CLEARANCE AREA, TYPICAL.
10' MINIMUM CLEARANCE TO OUTSIDE AIR INTAKES AND BUILDING OPENINGS, TYPICAL.
2 3
FOR PACKAGE ROOFTOP A/C UNIT INSTALLATION DETAIL, SEE 2/M3.1.
FOR ROOF MOUNTED EXHAUST FAN DETAIL, SEE 5/M3.1.
FOR CONDENSING UNIT MOUNTING DETAIL, SEE 6/M3.1.
FOR BOILER MOUNTING DETAIL, SEE 7/M3.1.
FOR VERTICAL INLINE PUMP DETAIL, SEE 8/M3.1.
FOR REFRIGERANT PIPING THRU ROOF DETAIL, SEE 7/M3.2.
FOR GAS VENT DETAIL, SEE 1/M3.3.
FOR EXHAUST FAN CONTROL DIAGRAM, SEE 3/M3.3.
FOR INTAKE AIR GOOSENECK DETAIL, SEE 4/M3.3.
FOR BOILER PIPING DIAGRAM, SEE 5/M3.3.
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
4 5
6 ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 292 of 357
PACKAGE ROOFTOP A/C UNIT INSTALLATION DETAIL
NO SCALE
DISCONNECT SWITCH (BY
ELECTRICAL CONTRACTOR)
FACTORY SUPPLIED
INSULATED ROOF CURB
FOR ATTACHMENT OF ROOF
CURB TO ROOF STRUCTURE
REFER TO STRUCTURAL AND
ARCHITECTURAL DRAWINGS
ROOF
ELECTRICAL WIRING UP THRU
CURB, THRU A/C UNIT CABINET
TO SIDE MOUNTED DISCONNECT
BY ELECTRICAL CONTRACTOR)
SD
OUTSIDE AIR INTAKE HOOD
FLEX CONNECTIONS (TYPICAL)
BASE RAIL BOLT TO NAILING STRIP
NAILING STRIP
FIELD SUPPLIED METAL FLASHING
INSERTED BETWEEN CURB LIP AND NAILING
STRIP. NAIL TO NAILING STRIP (TYPx4 SIDES)
SMOKE DETECTOR (WHERE SPECIFIED)
LINED DUCT WORK WHERE SHOWN
2 M3.1
NO SCALE
VAV TERMINAL BOX DETAIL
SEAL AIR TIGHT AND SECURE
TO TERMINAL UNIT WITH
MIN. (4) SHEET METAL SCREWS
VARIABLE AIR VOLUME TERMINAL
1" WIDE HANGER STRAP, SECURE
TO BUILDING STRUCTURE (TYPx4)
MIN. 3'-0" STRAIGHT DUCT RUN
AT THE INLET TO THE TERMINAL
SECURE HANGER STRAPS TO UNIT
WITH SHEET METAL SCREWS
DAMPER ACTUATOR
SEE CONTROL DIAGRAM)
BRANCH DUCT
12" MIN. FROM VAV
TERMINAL TO FIRST
BRANCH DUCT
CONNECTION
SHEET METAL PLENUM, SAME HEIGHT
AND WIDTH AS TERMINAL OUTLET, 1"
INSULATED LINING WITH 45°
TAPER AT TERMINAL CONNECTION
REHEAT COIL CONNECTIONS, SEE
REHEAT COIL PIPING DIAGRAM
REHEAT COIL (IF SCHEDULED)
SECURE HANGER STRAPS TO
UNIT WITH SHEET METAL SCREWS
1 M3.1
NO SCALE
VAV BOX REHEAT COIL PIPING DIAGRAM
DIELECTRIC COUPLING
WHERE REQUIRED)
SERVICE VALVE (TYPICAL)
COMBINATION AUTOMATIC FLOW
CONTROL DEVICE, PRESSURE AND
TEMPERATUREPORTS, SHUT-OFF
BALL VALVE, AIR VENT AND UNIONS
DESIGNER NOTE:
WHEN DISSIMILAR METAL PIPING
CONNECTIONS OCCUR (I.E. STEEL MAIN
AND COPPER RUN-OUT) THE SERVICE
VALVE MUST BE BRASS CONSTRUCTION
AND A DIELECTRIC COUPLING
PROVIDED.
COMBINATION SHUT-OFF BALL
VALVE, STRAINER, DRAIN, PRESSURE
AND TEMPERATURE PORT AND UNIONS.
UNION (TYP.)
BYPASS LINE SHUT-OFF/
BALANCING BALL
VALVE WITH MEMORY
STOPS.
SUPPLY MAIN
RETURN MAIN
2-WAY, TWO POSITIONS VALVE (SHOWN)
3-WAY VALVE SHOWN DASHED. SEE
SCHEDULE FOR LOCATION. TWO POSITION
VALVES FOR FLOW RATES 0.5 TO 5.0 GPM
HEATING COIL
3 M3.1
FOR CONTINUATION OF REFRIGERANT
PIPING SEE MECHANICAL PLANS
OUTDOOR WIRE TO OUTDOOR UNIT
FOR CONTINUATION OF CONDENSATE
PIPING SEE PLUMBING PLANS
REFRIGERANT PIPING TO OUTDOOR UNIT
PUMPED CONDENSATE TO
AN APPROVED RECEPTOR
WALL
FINISHED CEILING
FINISHED FLOOR
4" FROM CEILING MINIMUM
DUCTLESS FAN COIL UNIT
CONDENSATE PUMP
SHEET NOTES
1. FAN COIL REQUIRES 4" SERVICE CLEARANCE FROM TOP
AND LEFT SIDE, 8" SERVICE CLEARANCE ON RIGHT SIDE
2. UNIT SHALL BE INSTALLED IN STRICT CONFORMANCE
WITH THE MANUFACTURE'S INSTRUCTIONS, START-UP
AND SERVICE INSTRUCTIONS
DUCTLESS FAN COIL UNIT MOUNTING DETAIL
NO SCALE
4 M3.1
NO SCALE
ROOF MOUNTED EXHAUST FAN DETAIL
BIRDSCREEN
EXTEND DUCT TO
TOP OF ROOF CURB
FLASHING
ROOF BY GENERAL
CONTRACTOR
FASTEN THROUGH
ROOF CONSTRUCTION
ROOF
GALVANIZED IRON CLIP
ATTACHMENT TO ROOF
ROOF OPENING
DUCT SIZE +2"
INSULATED PRE-FAB
CURB (BY FAN MFGR.)
BACKDRAFT DAMPER
5 M3.1
NO SCALE
CONDENSING UNIT MOUNTING DETAIL
CONDENSING UNIT OR HEAT PUMP
2) #10x1/2" PLATED TEK SCREW
16GA GALVANIZED CORNER BRACE
MASONRY FASTENER 1/4"x1 1/4" HEAD
CONCRETE SLAB
6 M3.1
NEOPRENE PAD
12" CLEARANCE FROM
EDGE OF BASE TO BOILER
CANT STRIP
ROOFING
BOILER
2 1/2" x 2 1/2" x 3/16" x 12"LONG
ANGLE CLIP - (4) REQUIRED
PER BASE ONE PER SIDE
INTERMEDIATE
SUPPORT AS REQUIRED
ROOF CONSTRUCTION
SEE ARCH DRAWINGS
NEOPRENE PAD ISOLATORS
20 GAUGE GALVANIZED
IRON FLASHING
1 1/2" MARINE PLYWOOD
4"x6" WOOD EQUIPMENT BASE FRAME
SECURE TO ROOF WITH ANGLE CLIPS
BOILER MOUNTING DETAIL
NO SCALE
7 M3.1
12GA WIRE ATTACHED TO OPPOSING
CORNERS, CONNECT TO STRUCTURAL
CEILING (TYP), WIRES MAY BE SLACK
FLEXIBLE DUCT NOT TO EXCEED
7'-0" WHEN FULLY EXTENDED
ATTACH RIGID DUCT TO FLEX DUCT
WITH MINIMUM 2" WIDE STRAP (TYP)
DIFFUSER
ROUND DUCT
MANUAL AIR VOLUME DAMPER (TYP)
ROD CONTINUOUS ON ALL
DAMPERS OVER 12" DIAMETER
CONNECT TO STRUCTURAL (TYP)
CONNECT RIGID DUCT TO FLEX DUCT
WITH MINIMUM 1" WIDE STRAP (TYP)
DAMPER ARM WITH QUADRANT LOCK
ACOUSTIC CEILING TILE SHOWN. SEE
DIFFUSER MANUFACTURER
INFORMATION FOR GYP. BOARD CEILING
INFORMATION
T-RUNNER (TYP)
SECURE WITH (4) #10 SCREWS
FLEX DUCT BEND RADIUS SHALL
BE 2 TIMES THE DUCT RADIUS
DIFFUSER DETAIL
NO SCALE
9 M3.1
NO SCALE
8 M3.1
VERTICAL INLINE PUMP DETAIL
SYSTEM INLET
SYSTEM OUTLET
MIN. 2" DEFLECTION
VIBRATION ISOLATION (TYP)
SUCTION GUIDE
TRIPLE DUTY
VALVE
FLUSH LINE
PRESSURE
GAGE AND PIPING
PET
COCK
TYP)
DRAIN
CONNECTION
STRAINER SEE
SPECIFICATIONS FOR TYPE
PUMP MOTOR
SEE SPECIFICATIONS
FOR DETAILS
SHUTOFF VALVE.
SEE SPECIFICATIONS FOR TYPE
SPLIT
COUPLER
PIPE SUPPORTS (TYP)
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
DETAILS
200102
M3.1
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 293 of 357
MINIMUM 1" WIDE STRAP (TYP)
ROUND SUPPLY DIFFUSER
ROUND DUCT
DAMPER ARM WITH
QUADRANT LOCK
MANUAL AIR VOLUME
DAMPER (TYPICAL)
ROD CONTINUOUS ON ALL
DAMPERS OVER 12" DIAMETER
CONNECT TO STRUCTURAL
WITH 1/4" THREADED RODS
TYPICAL)
EXPOSED DUCTWORK DIFFUSER DETAIL
NO SCALE
2 M3.2
NO SCALE
RETURN AIR GRILL WITH FLEX TAIL/SOUND BOOT DETAIL
T-RUNNER (TYP)
ACOUSTIC CEILING TILE SHOWN. SEE
DIFFUSER MANUFACTURER
INFORMATION FOR GYP. BOARD
CEILING INFORMATION
FLEX DUCT BEND RADIUS SHALL BE 2
TIMES THE DUCT RADIUS
3"MIN.
DUCT SIZE
PER FLOOR PLANS
RETURN AIR TO
CEILING PLENUM
CONNECT TO STRUCTURE
TYP)
12GA. WIRE ATTACHED TO OPPOSING
CORNERS, CONNECT TO STRUCTURAL
CEILING (TYP), WIRES MAY BE SLACK
FLEXIBLE DUCT NOT
TO EXCEED 5'-0"
ATTACH FLEX DUCT TO
STRUCTURAL W/MIN.
2" WIDE STRAP (TYP)
1 M3.2
NO SCALE
TRANSFER AIR DETAIL
T-RUNNER (TYP)ACOUSTIC CEILING TILE SHOWN. SEE
DIFFUSER MANUFACTURER
INFORMATION FOR GYP. BOARD
CEILING INFORMATION
SECURE WITH
4) #10 SCREWS
DIFFUSER
12GA. WIRE ATTACHED TO OPPOSING
CORNERS, CONNECT TO
STRUCTURAL CEILING
TYP), WIRES MAY BE SLACK
FLEXIBLE DUCT NOT
TO EXCEED 7'-0"
WHEN FULLY EXTENDED
ATTACH RIGID DUCT TO
FLEX DUCT WITH MIN.
2" WIDE STRAP (TYP)
CONNECT TO
STRUCTURAL (TYP)
ATTACH RIGID DUCT TO
FLEX DUCT WITH MINIMUM
1" WIDE STRAP (TYP)
ROUND
DUCT (TYP)
FLEX DUCT BEND RADIUS
SHALL BE 2 TIMES THE
DUCT RADIUS (TYP)
INTERIOR WALL
3 M3.2
NO SCALE
TYPICAL DUCT TAKEOFF DETAILS
3'-0" MAX
THIS DIMENSION MUST
BE AT LEAST 1/2 "D"
D"
30° OR LESS
TYPICAL)
DUCT UNDER BEAM OR CROSSOVER SECTION
NO SCALE
BRANCH DUCT
45°
MAIN
D"
4 D"
RECTANGULAR BRANCH DUCT
NO SCALE
BRANCH FLEX OR
SPIRAL DUCT
MANUAL VOLUME
DAMPER ON FITTING
TYPICAL)
45°
MAIN
ROUND BRANCH DUCT
NO SCALE
RECTANGULAR MAIN/ROUND BRANCH DUCT
NO SCALE
ROUND BRANCH
FLEX DUCT OR
SPIRAL DUCT
MANUAL VOLUME
DAMPER
RECTANGULAR)
MAIN DUCT
SADDLE TAP OR
SPIN-IN FITTING
45°
4 M3.2
HANGER
STRAPS
MA
X
IM
U
M
S
P
A
C
IN
G
SCREWS
SLING, AVOID
DISRUPTION OF
INSULATION
BAND OF SAME SIZE
AS HANGER STRAP
HANGER
STRAP
LOAD-RATED
FASTENERS
12 12
3"
1" MIN
12 ROUND DUCT RECTANGULAR DUCT
DUCT SUPPORT DETAIL
NO SCALE
5 M3.2
12"O.C. MAX
2"
NOTES:
1. METAL FASTENERS OMARK INSUL-PINS, DURA DYNE
FASTENERS OR GRIP NAILS
2. GRIP NAILS SHALL BE INSTALLED BY GRIP NAIL
HAMMER OR BY AUTOMATIC FASTENER EQUIPMENT
GALVANIZED IRON DUCT
ALL ENDS OF LINER TO BE COATED
WITH ADHESIVE (MIRACLE PF96)
ENDS OF LINER SHALL BE
BUTTED FIRMLY TOGETHER
DUCT LINER MIN 1 1/2 PCF 1.0" THICK
NOT MORE THAN 2"
FROM EDGE OF LINER
TOP AND BOTTOM
SECTION OF LINER SHALL
OVERLAP THE SIDES
DUCT LINER MIN 1 1/2 PCF 1.0" THICK
LINER TO BE ADHERED TO DUCT
DUCT LINER DETAIL
NO SCALE
6 M3.2
NO SCALE
REFRIGERANT PIPING THRU ROOF DETAIL
SEAL END OF DUCT
AROUND PIPE WITH
SPRAY FOAM
DX PIPING TO CONDENSING
UNITS
COPPER DX
PIPES WITHIN 6"ø
GALVANIZED STEEL
DUCTWORK
DX PIPING TO FAN COIL
SEAL OPENING
ROOFING
GALVANIZED
STEEL
FLASHING
CONTINUOUS
SEAL 6"ø DUCT
TO FLASHING
7 M3.2
NO SCALE
VERTICAL DX PIPE SUPPORT DETAIL
WALL
SECURE RISER
CLAMP TO CONC.
WALL WITH 3/8"ø
EXPANSION BOLT.
FRONT VIEW SIDE VIEW
PIPE
INSULATION
OFFSET RISER CLAMP
8 M3.2
PIPE SUPPORT DETAIL
SLEEVE AND PIPE PROTECTION SADDLES.
PIPE & INSULATION WITH FULL CIRCLE
CHANNEL
UNIVERSAL
OF 4 PER SUPPORTS
SADDLES TIGHT TO WALL
FULL CIRCLE SLEEVE
PIPE INSULATION WITH
AND PIPE PROTECTION
BOLT MIN.
WALL
SUPPLY & RETURN PIPING
HOT WATER HEATING
TYPICAL)
HANGER RODS
UNISTRUT
NO SCALE
9 M3.2
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
DETAILS
200102
M3.2
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 294 of 357
MINIMUM 10'-0" FROM
OPENINGS INTO THE BUILDING
OSHPD PROJECTS: MINIMUM 25'-0"
FROM OPENING INTO THE BUILDING)
24" MINIMUM
VENT CAP
STORM COLLAR
FLASHING
ROOFING
GAS VENT
GAS VENT DETAIL
NO SCALE
1 M3.3
NO SCALE
THERMOSTAT MOUNTING DETAIL
TOP OF
THERMOSTAT
FINISHED
FLOOR
46"
MAX
34"
MAX
24" MAX
T
OVEROBSTRUCTIONMOUNTINGHEIGHT
T
CENTERLINE OF
THERMOSTAT
FINISHED
FLOOR
48"
MAX
NOTE:
THERMOSTATS ARE TO BE LOCATED NO MORE THAN 48" ABOVE FINISHED FLOOR 46" MAXIMUM HEIGHT IF LOCATED OVER A COUNTER)
24" MAXIMUM REACH DEPTH AT COUNTER)
COORDINATE WITH ARCHITECTURAL DRAWING
2 M3.3
SEE SCHEDULE FOR VOLTAGE
LINE VOLTAGE THERMOSTAT
SET AT 85° F HONEYWELL
MODEL #T6054A
SEE SCHEDULE FOR VOLTAGE
TO LINE VOLTAGE
WALL SWITCH
CONTROLS LEGEND
POWER WIRING BY ELECTRICAL
CONTROL WIRING BY MECHANICAL
BY MECHANICAL CONTRACTOR
BY ELECTRICAL CONTRACTOR
NO SCALE
EXHAUST FAN CONTROL DIAGRAM
3 M3.3
M
E
INTERNAL MOTOR
THERMAL SWITCH
M
EXHAUST FAN EXHAUST FAN
M
E
E
M
E
1-1/2"
LAG PUMP
SUCTION
DIFFUSER
STRAINER
NOTE:
PROVIDE DRAINS AT ALL LOW POINTS
AND AIR VENTS AT ALL HIGH POINTS.
PRESSURE RELIEF VALVE.
RUN DISCHARGE FULL SIZE
TORECEPTORBYPASS
CONTRACTOR
CHEMICAL POT
FEEDER
BY PLUMBING
1" MAKE-UP WATER
LEAD PUMP
AUTOMATIC
AIR VENT
AIR
SEPARATOR
EXPANSION
TANK
DRAIN PIPING SHALL
EXTEND TO RECEPTOR
BALANCE VALVE (TYP)
ISOLATION BALL VALVE
ISOLATION BALL
VALVE
BYPASS VALVE
3-WAY VALVE
BOILER
RELIEF LINE RUN FULL
SIZE OF RELIEF VALVE
TO RECEPTOR
PETES PLUG
TYPICAL)
PUMP
BALANCE VALVE
SHUT OFF VALVE COIL
B
1 P
1 ET
1 P
2 AS
1 1-1/2"
1-1/2"
1-1/2"1-1/2"
1-1/2"
1-1/2" 1-1/2"
1-1/2"
1-1/2"
NO SCALE
BOILER PIPING DIAGRAM
5 M3.3
NO SCALE
4 M3.2
INTAKE AIR GOOSNECK AT ROOF DETAIL
CANT STRIP
DUCT
CAULK OR SEAL
3/4" PLYWOOD
90° (DEGREE)
CURB STRUCTURAL
SUPPORTS
ROOF
SHEATHING
COUNTER
FLASHING
20 GAUGE
GALVANIZED
STEEL CAP
BUILD UP ROOFING
4x8 WOOD AT PERIMETER,
AT 12" ON CENTER
SCREEN
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
DETAILS
200102
M3.3
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 295 of 357
VAV-01 VAV-02 VAV-03 VAV-04 VAV-05 VAV-06 VAV-07 VAV-08 VAV-09 VAV-10 VAV-12 VAV-13 VAV-14 VAV-15 VAV-16 VAV-17 B1
Boiler
P-1
VFD
P-2
VFD
HHW
BTU
SF
VFD
PLC
RTU-1
HHW System
Panel
CAT5e
EF
VFD
BACnet IP
MSTP
MSTP
BSM RISER DIAGRAM
NO SCALE
1 M4.1
P-2
1.5 HP
25 gpm
DI
MSTP
VSD
R
AO
DO
HHWS
AI-P
AI-T
AI-T
AI-F
MSTP
24 VAC
BTU
Meter
P-1
1.5 HP
25 gpm
DI
MSTP
VSD
R
AO
DO
Boiler B1
252 MBH
25 gpm
BP-1
0.75 HP
71 gpm
DI
Self-Actuated
Diverting Valve
BACnet MSTP
AI-T
HHWR
Outside Air
Mtd in Eq Yard
AI-H
AI-T
AI-T
Mtd on Roof
L
H
HEATING HOT WATER SYSTEM
NO SCALE
2 M4.1
Sup ASC
Htg
AI
T & CO2
AO
AO
MSTP
24 VAC
Ret
AI
T
Poly
Tubing
Exh
PE
1 HP
SF
10 HP
10,000 cfm DX
RTU-1
2-Way
Eq Pct Valve
Fail to Last
Command
Backdraft
Damper
MSTP
Poly
Tubing
Open Work Area
Ceiling
RTU-1 furnished
with factory
controls
OSA
Typ 17
CO2 in Conf
Room and Break
RoomonlyRTU-1 DIAGRAM
NO SCALE
3 M4.1
Exh
Exh
EF-01 Fract HP 250 cfm Electrical Room
Exh
DO
DI
Exh
R
EF-02 Fract HP 1,500 cfm Mens Locker Room
EF-03 Fract HP 150 cfm Washroom
EF-04 Fract HP 900 cfm Womens Locker Room
EF-05 Fract HP 350 cfm Fitness Room
EF-06 Fract HP 250 cfm Break & Copy Rooms
Line Voltage
Thermostat
2-#16
EXHAUST CONTROL DIAGRAMS
NO SCALE
4 M4.1
SEQUENCE OF OPERATION
NO SCALE
5 M4.1
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
MECHANICAL
CONTROL
DIAGRAMS
200102
M4.1
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 296 of 357
No. 30090
O
A
O
C
LER
E
TS EM
AT
EETSGI GG
DUUOO
RPD NESIRS
FICLFA
GI
AACANHIINL
OR
AASK EEN
OIFESSN AL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
TITLE 24
DOCUMENTATION
200102
M5.1
AE
DI
RA
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
ISSUED FOR
CONSTRUCTION
02/11/21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 297 of 357
GENERAL NOTES
CONTRACTOR SHALL CAREFULLY REVIEW THESE PLANS AND
SPECIFICATIONS PRIOR TO BID. CONTRACTOR SHALL ALSO REVIEW
PLANS AND SPECIFICATIONS OF OTHER RELATED TRADES
INCLUDING ARCHITECTURAL, MECHANICAL, STRUCTURAL, CIVIL AND
ELECTRICAL) PRIOR TO BID TO INSURE AN ACCURATE
UNDERSTANDING OF EXACT SCOPE OF WORK.
EQUIPMENT INDICATED ON THESE DRAWINGS ARE SHOWN IN
APPROXIMATE LOCATIONS. THE CONTRACTOR SHALL FIELD VERIFY
ALL EXISTING CONDITIONS INCLUDING EQUIPMENT LOCATIONS,
STRUCTURAL MEMBERS, P.O.C.'S, INVERT ELEVATIONS AND
AVAILABILITY OF ALL EXISTING UTILITIES PRIOR TO INSTALLATION.
NOTIFY THE CONSTRUCTION COORDINATOR OF ANY DISCREPANCIES OR CONFLICTS PRIOR TO COMMENCING ANY WORK. DO NOT
PROCEED WITHOUT CONSTRUCTION COORDINATOR APPROVAL FOR
ANY CHANGES IF REQUIRED.
PLUMBING EQUIPMENT, MATERIAL AND CONNECTIONS SHALL BE
INSTALLED COMPLETE PER MANUFACTURER'S INSTRUCTIONS TO
PROVIDE A COMPLETE AND FULLY OPERATIONAL SYSTEM.
WORK SHALL CONFORM TO CODE. IN CASE OF CONFLICTS WITH
CODE, DRAWINGS, OR SPECIFICATIONS, THE MORE STRINGENT
SHALL PREVAIL.
PLUMBING SHALL BE INSTALLED TO AVOID INTERFERENCE WITH
ELECTRICAL AND MECHANICAL EQUIPMENT AND STRUCTURAL
FRAMING. COORDINATE WITH ALL OTHER TRADES, STRUCTURAL
CONDITIONS AND BUILDING CONSTRUCTION, PRIOR TO START OF INSTALLATION.
EXACT LOCATION AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.
COORDINATE LOCATION OF CONDENSATE DRAIN CONNECTIONS TO
MECHANICAL EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR
TO INSTALLATION.
PLUMBING LINES SHALL BE CONCEALED WITHIN THE BUILDING
STRUCTURE TO AS GREAT EXTENT AS POSSIBLE.
PIPING SYSTEMS SHALL BE SEISMICALLY BRACED PER CALIFORNIA BUILDING CODE.
SOIL, SEWER, WASTE AND STORM DRAIN PIPING SHALL SLOPE AT 1/4" PER FOOT MINIMUM UNLESS INDICATED OTHERWISE.
VALVES SHALL BE READILY ACCESSIBLE. WHERE VALVES ARE
INSTALLED WITHIN OR BEHIND WALLS, AN ACCESS PANEL SHALL BE INSTALLED.
OUTLETS FOR FUTURE CONNECTIONS SHALL BE INSTALLED TO
PERMIT EASY CONNECTION. COORDINATE WITH DUCTWORK,
STRUCTURAL CONDITIONS AND ARCHITECTURAL LAYOUT.
BUILDING DRAIN AND VENT PIPING MATERIALS SHALL COMPLY WITH SECTIONS 701.0 AND 903.0 OF THE CALIFORNIA PLUMBING CODE.
ALL SANITARY SYSTEM MATERIALS SHALL BE LISTED BY AN
APPROVED LISTING AGENCY.
ALL INTERIOR CONDENSATE DRAIN PIPING SHALL BE INSULATED.
PROVIDE VACUUM BREAKERS AT ALL HOSE BIBS.
FAUCETS SHALL HAVE A FLOW RESTRICTION DEVICE NOT TO EXCEED
2.2 GPM. LAVATORIES IN PUBLIC AREAS SERVING THE TRANSIENT
PUBLIC SHALL HAVE SELF CLOSING FAUCETS, PER CPC SECTION 402.4.
WATER CLOSETS SHALL BE ULTRA LOW FLUSH TOILETS, 1.28 GPF MAXIMUM, PER CPC SECTION 402.2.
URINALS SHALL BE ULTRA LOW FLUSH URINALS, 0.125 GPF MAXIMUM, PER SECTION 402.3.
SHOWERHEADS SHALL HAVE A MAXIMUM FLOW OF 2.0 GPM AND
SHALL HAVE A MIXING VALVE AT SHOWER CONTROLS.
WATER HEATER/BOILER WILL COMPLY WITH CPC SECTION 608.3 FOR THERMAL EXPANSION REQUIREMENTS.
WATER HEATERS SHALL BE LISTED IN THE CALIFORNIA ENERGY
COMMISSION LIST OF APPROVED WATER HEATERS.
INSULATING MATERIALS INSTALLED SHALL BE CERTIFIED BY
CALIFORNIA ENERGY COMMISSION TO MEET C.E.C. ENERGY
EFFICIENCY STANDARDS (E.E.S) SECTION 118, 123, 124.
PLUMBING EQUIPMENT SHALL BE CERTIFIED BY AND COMPLY WITH
THE STATE OF CALIFORNIA ENERGY CONSERVATION STANDARDS
E.E.S.) SECTION 113. COMPLIANCE CERTIFICATES SHALL BE
PROVIDED WITH EQUIPMENT SUBMITTALS.
WATER HEATERS FOR DOMESTIC HOT WATER AND/OR POOLS SHALL
COMPLY WITH THE STATE OF CALIFORNIA ENERGY EFFICIENCY
STANDARDS (E.E.S.) SECTION 113. AND 114.
DO NOT ROUTE PIPING OVER ELECTRICAL ROOMS, MDF ROOMS, IDF ROOMS, COMPUTER ROOMS OR ELEVATOR EQUIPMENT ROOMS.
EXCEPTION: PIPES REQUIRED TO SERVE THE ROOM.
FLOOR DRAINS OR SIMILAR TRAPS DIRECTLY CONNECTED TO THE
DRAINAGE SYSTEM AND SUBJECT TO INFREQUENT USE SHALL BE
PROVIDED WITH AN APPROVED AUTOMATIC MEANS OF MAINTAINING THEIR WATER SEALS.
CROSS CONNECTION PROTECTION SHALL BE PROVIDED AT ALL
POTABLE WATER SUPPLIED APPLIANCES AND EQUIPMENT (OTHER
THAN THOSE LISTED IN INFORMATION BULLETIN 103 OF THE SAN DIEGO MUNICIPAL CODE.
WATER HEATERS SHALL BE ANCHORED OR STRAPPED TO RESIST
HORIZONTAL DISPLACEMENT DUE TO EARTHQUAKE MOTION, PER
CPC SECTION 508.2.
EACH WATER HEATER (WH-1) IS A LISTED, NON-STORAGE,
INSTANTANEOUS HEATER, HAVING AN INSIDE DIAMETER OF NOT
MORE THAN 3 INCHES.
THE PROJECT WILL COMPLY WITH THE COUNTY OF SAN DIEGO
FIGHTING ORDINANCE.
ROOF TOP PIPING EXPOSED TO WEATHER OR SUNLIGHT MUST BE
METTALIC.
ALL FERROUS PIPING EXPOSED TO WEATER MUST BE GALVANIZED.
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
11. 12.
13. 14.
15. 16.
17. 18.
19. 20.
21. 22.
23. 24.
25. 26.
27. 28.
29. 30.
TEMPERATURE & PRESSURE RELIEF VALVE [DIAGRAMMATIC]
WATER HAMMER ARRESTOR (P.D.I. SIZE) [DIAGRAMMATIC]
DOWN OR DROP [DIAGRAMMATIC]DN
RISE OR RISER [DIAGRAMMATIC]
UNION (DIELECTRIC) [DIAGRAMMATIC]
FLOOR SINK
WALL HOSE BIBB [DIAGRAMMATIC]
FLOOR DRAIN
FS
FD
WHA( )
U
WHB
UP
HOT WATER RETURN PIPING
TRAP PRIMER LINE
SHUT-OFF-VALVE (GATE VALVE) [DIAGRAMMATIC]
CHECK VALVE [DIAGRAMMATIC]
FLOOR CLEAN OUT [DIAGRAMMATIC]
WALL CLEAN-OUT [DIAGRAMMATIC]
CAPPED LINE [DIAGRAMMATIC]
CLEAN-OUT TO GRADE [DIAGRAMMATIC]
PRESSURE REDUCING VALVE [DIAGRAMMATIC]
RV
WCO
CL
COG
FCO
TP
PRV
CV
HWR
SOV
TP
DESCRIPTION
CONDENSATE DRAIN PIPING
SANITARY VENT PIPING
COLD WATER PIPING
HOT WATER PIPING (120°)
POINT OF CONNECTION
SOIL OR WASTE BELOW SLAB
CD
CW
HW
V
CD
SYMBOL
POC
S
ABBREV.
SOV SHUT-OFF-VALVE (BALL VALVE) [DIAGRAMMATIC]
HB HOSE BIBB [DIAGRAMMATIC]
RPBP REDUCED PRESSURE PRINCIPAL BACKFLOW
PREVENTER [DIAGRAMMATIC]
CUBIC FEET PER HOUR
BRITISH THERMAL UNITS PER HOUR
AMERICANS WITH DISABILITIES ACT
ABOVE FINISHED FLOOR
CUBIC FEET PER MINUTE
HEATING, VENTILATING, & AIR CONDITIONING
POUNDS PER SQUARE INCH
UNIFORM PLUMBING CODE
QUANTITYQTY
TYPICAL
SQUARE FEET
WITH
VOLTS/PHASE/HERTZ
VENT THRU ROOF
W/
V/PH/HZ
SF
TYP
UPC
VTR
POUNDS
MAXIMUM
OPERATING
NUMBER
MINIMUM
MANUFACTURER'S
MAX
NO
OPER
MFR'S
PSI
IN
INT
LBS
MIN
INCH
INTEGRAL
CFH
EACH
FEET/FOOT
GALLONS PER MINUTE
FEET PER SECOND
GALLONS PER HOUR
HORSE POWER
EXISTING
GPM
GPH
HP
HVAC
EA
FT
FT/SEC
E)
ABOVE CEILING
BELOW FLOOR
BELOW GRADE
BUILDING
B/F
B/G
CFM
BLDG
A/C
BTUH
AFF
ADA
PLUMBING LEGEND & ABBREVIATIONS
VARIABLE FREQUENCYDRIVEVFD
FIXTUREUNITFU
GALLONGAL
TOTAL DEVELOPEDLENGTHTDL
CALIFORNIA PLUMBING CODE
CALIFORNIA BUILDING CODE
CPC
CBC
WATER HAMMER ARRESTOR TYPE 'A'WHA-'A'
SOIL OR WASTE ABOVESLABS
AB 1953 COMPLIANCE
PIPE, PIPE FITTINGS, VALVES AND FIXTURES INTENDED TO CONVEY OR
DISPENSE WATER FOR HUMAN CONSUMPTION THROUGH DRINKING OR COOKING, SHALL BE CERTIFIED TO BE "LEAD FREE" AS DEFINED BY STATUTE AB 1953. NOTHING CONTAINED IN THESE DRAWINGS OR SPECIFICATIONS IS INTENDED TO VIOLATE THIS STATUTE.
NOTICE
THE EQUIPMENT MATERIALS AND COMPONENTS OF THE DESIGN SHOWN ON THE
MECHANICAL AND PLUMBING PLANS AND SUPPORTING DOCUMENTS AND
SPECIFICATIONS HAVE BEEN DEVELOPED FOR AN OWNER/ DEVELOPER AS RENTAL LIVING UNITS. THE EQUIPMENT, MATERIALS, AND COMPONENTS ARE BASED ON FIRST
COST AND BEST VALUE AND MAY THEREFORE REQUIRE ADDITIONAL MAINTENANCE AND OR REPLACEMENT THAN THOSE OF FOR SALE CONDOMINIUM UNITS. A MAJOR
MODIFICATION COULD BE REQUIRED AT THE OWNER/ DEVELOPER'S EXPENSE IF THE
APARTMENT PROJECT WERE TO BE CONVERTED TO A FOR SALE PRODUCT SUCH AS A CONDOMINIUM. FURTHERMORE, THE CONSTRUCTION MEANS, METHODS,
TECHNIQUES, PROCEDURES AND SEQUENCES ARE SOLELY THE RESPONSIBILITY OF
THE GENERAL CONTRACTOR AND ITS SELECTED MECHANICAL AND PLUMBING SUBCONTRACTOR.
PRESSURE LOSS THROUGH EXISTING BACKFLOW
ALLOWABLE MAXIMUM FRICTION LOSS PER 100 FT. OF PIPE
MAXIMUM DEVELOPED LENGTH OF WATER SYSTEM FT.
PRESSURE AVAILABLE FOR DROP (DESIGN PRESSURE)
METER (REGULATOR) TO HIGH OUTLET FT. X .43 =
REGULATED PRESSURE PSI X 0.8
PRESSURE AVAILABLE
DEVELOPED PRESSURE LOSS THROUGH EXISTING METER
NORMAL MINIMUM PRESSURE AT MAIN
RESIDUAL PRESSURE REQUIRED
95 PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
PSI
EXISTING METER SIZE INCH GPM AT 80% CAPACITY.
SOFT WATER CONNECTION WILL WILL NOT BE USED.
FLUSHOMETER TANK TYPE FIXTURES PREDOMINANTLY USED.
TOTAL FIXTURE UNITS . DEMAND FLOW GPM.
NUMBER OF BUILDING STORIES
METER LOCATIONS:
1 1/2
1 94
1165 E TAYLOR ST, VISTA, CA 92084
65 80
WATER CALCULATIONS
CW PIPE SIZING
SIZE GPM FT/SEC
FIXTURE UNITS
FLUSH TANK FLUSH VALVE
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
HW PIPE SIZING
SIZE GPM FT/SEC
FIXTURE UNITS
FLUSH TANK FLUSH VALVE
1/2"
3/4"
1"
1 1/4"
1 1/2"
2"
ENERGY CONSERVATION NOTES
1.EQUIPMENT SHALL MEET THE APPLICABLE REQUIREMENTS OF THE APPLIANCE EFFICIENCY REGULATIONS PER SECTION 110.1.
2.ALL PIPE INSULATION MATERIAL SHALL MEET THE REQUIREMENTS PER SECTION 120.3 E.E.S.
3.SERVICE WATER-HEATING SYSTEMS AND EQUIPMENT SHALL MEET THE REQUIREMENTS PER SECTION 110.3 E.E.S.
FIXTURE UNIT SUMMARY
FIXTURE QTY
WATER
WSFU TWSFU DFU TDFU
SANITARY
94 65
63TOTALSUMMARY =
TOTAL GPM =
PIPE MATERIAL SCHEDULE
SOIL, WASTE, GREASE WASTE, VENT, STORM DRAIN AND OVERFLOW STORM DRAIN PIPE ABOVE AND BELOW GRADE TO 5'-0'' OUTSIDE BUILDING:
CAST IRON, HUBLESS WITH STAINLESS STEEL CLAMPS, OR FOR BELOW GRADE SCHEDULE 40 ABS DWV (SOLID CORE) WITH ABS FITTINGS.
WATER PIPING ABOVE GRADE:
COPPER TYPE "L", HARD DRAWN, WITH LEAD-FREE SOLDER. DOMESTIC HOT WATER TO BE INSULATED.
WATER PIPING BELOW GRADE:
COPPER TYPE "K", HARD DRAWN, WITH LEAD-FREE SOLDER.
CONDENSATE DRAIN ABOVE GRADE:
COPPER TYPE "M", WITH LEAD-FREE SOLDER.
STANDARDS FOR PLUMBING
FIXTURES AND FIXTURE FITTINGS
REQUIRED STANDARDS
WATER CLOSETS (TOILETS)-FLUSHOMETER
VALVE TYPE SINGLE FLUSH, MAXIMUM
FLUSH VOLUME
WATER CLOSETS (TOILETS)-FLUSHOMETER
VALVE TYPE DUAL FLUSH, MAXIMUM FLUSH
VOLUME
WATER CLOSETS (TOILETS)-TANK TYPE
URINALS, MAXIMUM FLUSH VOLUME
URINALS, NON WATER URINALS
PUBLIC LAVATORY FAUCETS: MAXIMUM
FLOW RATE - 0.5 PM (1.9 AL/MIN)
PUBLIC METERING SELF-CLOSING
FAUCETS: MAXIMUM WATER USE - 0.25
GAL (1.0 AL) PER METERING CYCLE
RESIDENTIAL BATHROOM LAVATORY SINK
FAUCETS: MAXIMUM FLOW RATE - 1.5 PM
5.7 AL/MIN)
ASME A 112.19.14 AND U.S.EPA
WATERSENSE TANK-TYPE HIGH-EFFICIENCY
TOILET SPECIFICATION - 1.28 GAL (4.8 AL)
U.S.EPA WATERSENSE TANK-TYPE HIGH-
EFFICIENCY TOILET SPECIFICATION
ASME A 112.19.2/NCSA B45.1 - 0.5 GAL (1.9
AL)
ASME A 112.19.19 (VITREOUS CHINA) ANSI
Z124.9-2004 OR IAPMO Z124.9 (PLASTIC)
ASME A 112.18.1/CSA B125.1
ASME A 112.18.1/CSA B125.1ASMEA112.18.1/CSA B125.1
ASME A 112.18.1/CSA B125.1
ASME A 112.19.2/NCSA B45.1 - 1.28 GAL
4.8 AL)
PER 2016 BUILDING ENERGY EFFICIENCY STANDARDS, TABLE 120.3-A.
PIPE INSULATION SCHEDULE
FLUID
TEMP.
RANGE (ºF)
CONDUCT.
RANGE
BTUH/SF
PER ºF)
INSULATION
MEAN
RATING
TEMP. (ºF)
NOMINAL PIPE DIAMETER
105-140 0.22-0.28 100 1.0"
Less than 1"
1.5"
1" or larger
INSULATION THICKNESS REQUIRED
PER SECTION 5.303.3 PLUMBING FIXTURES (WATER CLOSETS) AND FITTINGS FAUCETS AND SHOWERHEAD) SHALL COMPLY WITH THE FOLLOWING:
5.303.3.1 WATER CLOSETS:
EFFECTIVE FLUSH VOLUME SHALL NOT EXCEED 1.28 GPF.
5.303.3.3.1 SINGLE SHOWERHEAD:
MAXIMUM FLOW RATE OF NOT MORE THAN 2.0 GPM AT 80 PSI.
5.303.3.4.1 NON-RESIDENTIAL LAVATORY FAUCETS:
MAXIMUM FLOW RATE OF NOT MORE THAN 0.5 GPM AT 60 PSI.
5.303.3.4.4 METERING FAUCETS:
FLOW RATE SHALL NOT DELIVER MORE THAN 0.20 GAL PER CYCLE.
5.303.3.6 STANDARDS FOR PLUMBING FIXTURES:
PLUMBING FIXTURES AND FITTINGS SHALL BE INSTALLED IN
ACCORDANCE WITH THE CALIFORNIA PLUMBING CODE, AND SHALL MEET THE APPLICABLE STANDARDS REFERENCED IN TABLE 1701.1 OF THE CALIFORNIA PLUMBING CODE AND IN CHAPTER 6 OF CALIFORNIA GREEN BUILDING STANDARDS CODE.
CAL GREEN CODE
NON-RESIDENTIAL MANDATORY
MEASURES
8.6 11
75.4 65
6.45 35
23.55 4
15 600
2 6
13 20
33 69 7
5.75 5.25
4.5 3.5
2.75 220
60 30
18 7
1 -
16 105
27 49 5
5 123
46 -
2 6
13 20 5
4.5 3.5
2.75 30
18 7
1 -
31. UNLESS NOTEDOTHERWISEU.N.O.
WATER CLOSET (FV)
URINAL (FV)
LAVATORY
SHOWER
BREAK SINK
KITCHEN SINK
9 3
10 3
1 1 1.51.5
2.0 2.0
1.0 4.0
5.0 45
12 10
6 2
2.0 2
2 6
10 6
364.0
2.0 2.0
2.0 1.0
HOSE BIBB 5 2.5 ----
1.0 2.5
4.0 X
X
DRINKING FOUNTAIN 2 10.5 0.5 1
COOLER FILLING STATION 1 55 ----
EMERGENCY EYE WASH 1 55 ----
32. 33.
No. 30090
O
A
O
C
LER
ETS EM
AT
EETSGI GGDUUOO
RPD NESIRS
FICLFA
GI
AACANHIINLOR
AASK EEN
OIFESSNAL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
PLUMBING
GENERAL
NOTES AND
LEGEND
200102
P0.1
AC
DI
AC
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
02/ 11/ 21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 298 of 357
FIXTURE CONNECTION SUMMARY
SYMBOL DESCRIPTION
PIPE SIZES (INCHES)
CW HW W V TRAP
REMARKS
WC-1
L-1
MS-1
HB-1
S-1
WATER CLOSET
LAVATORY (ADA)
MOP SINK
HOSE BIBB
SINK
1 1/4
1 1/4
3/4 3/4
3/4
1/21/2
1/2 1/2 2 211/2
1 1/2
2 2
24 3 3
INT
SYMBOL DESCRIPTION
GAL.
CAPACITY
EQUIPMENT SCHEDULE
EMERGENC
Y
POWER
ELECTRICAL DATA
VOLT PHASE CYCLE H.P.
OPER.
WEIGHT
LBS.)
MANUFACTURER & MODEL NUMBER
MV
1 MIXING VALVE --------------ACORN MV17-2
ET
1 THERMAL
EXPANSION TANK ------------55
WATER HEATER SCHEDULE
SYMBOL DESCRIPTION
WH
1 WATER HEATER
GALLON
STORAGE
80 199,000
BTU INPUT
GPH
RECOVERY
338
ELECTRICAL DATA
VOLT PHASE CYCLE WATTS FLA
OPER.
WEIGHT
LBS.)
MANUFACTURER & MODEL NUMBER
60 278 ---- RINNAI DEMAND DUO #CHS19980HEiN120
1 P0.2
GAS PIPING DIAGRAM
DESCRIPTION
WATER HEATER
HHW BOILER
CLOTHES DRYER
BBQ GRILL
GAS CALCULATIONS
QUANTITY
1 1
1 1
BTUH
199,000
300,000
80,000
70,000
TOTAL BTUH
199,000
300,000
80,000
70,000
TOTAL BTUH DEMAND
TOTAL CFH DEMAND (BTUH ÷ 1000)MAXIMUM
DEVELOPED LENGTH OF LOW PRESSURE GAS PIPING: (7"W.C.)ALL GAS PIPING SIZED PER 2019 CPC LOW
PRESSURE GAS SIZED AT 7"W.C.FOR
GAS PIPING DIAGRAM SEE 1/P0.2 649,
000 649
350'
E)
GAS METER AND PRESSURE REGULATOR 5PSI
TO 7"W.C.649
CFH 220'
TOTAL DEVELOPED LENGTH FROM REGULATOR TO BUILDING E)
EARTHQUAKE VALVE
MANUAL RESET 2
1/2"G 649
CFH E)
GAS COCK TYP.)
LEVEL
1 ROOF
MARK
CIRCULATION
PUMP
TYPE
PH
ELECTRICAL
PUMP
SCHEDULE DOMESTIC
HOT WATER
SYSTEM
SERVED GRUNDFOS
UPS
15-55 SUC/TLC MANUFACTURER &
MODEL
NO.3
GPM
IN-
LINE4FEET
HEAD
OF
TYPE 115
VOLT
REMARKS
AMPS
601 .
7487 WATTSCYCLE
1/
25 10 H.
P.OPER.
LBS.)
WEIGHT
P
1 SS
PUMP HOUSING, 3-SPEED PUMP W/ BUILT-IN ISOLATING
AND NON-RETURN VALVES. PROVIDE W/ TIMER
AND AQUASTAT CONTROLS. INSTALL PER MANUFACTURER'
S RECOMMENDATION.U-
1 URINAL 3/4 1 1/22--INT SLOAN #
WEUS-1000.1303, VITROUS CHINA, TOP SPUD, ELECTRONIC HARD WIRED SENSOR FLUSH VALVE WITH LOW VOLTAGE TRANSFORMER, 0.125 GPF MAXIMUM. PROVIDE WITH WALL CARRIER.L- 2 LAVATORY (ADA)1 1/41/21/21 1/22SLOAN #
WETS-2450.1303, ELONGATED VITROUS CHINA BOWL, SIPHON JET, FLUSH VALVE, ELECTRONIC HARD WIRED SENSOR WITH LOW VOLTAGE TRANSFORMER, 1.28 GPF MAXIMUM. PROVIDE WITH WALL CARRIER.
KOHLER #
K-2211-0 VITREOUS CHINA, UNDERMOUNT, SINGLE HOLE, WITH SLOAN #EFX-600-BOX-BDT-CP-0. 5GPM-MLM-IR-FCT HARDWIRED FAUCET WITH LOW VOLTAGE TRANSFORMER AND SLOAN ESD- 400-BN, ANGLE STOPS, SUPPLIES, 'P' TRAP, AND POP UP WASTE.AMERICAN STANDARD #9134001EC VITREOUS CHINA, WALL MOUNT, SINGLE HOLE, WITH SLOAN #EFX-600-BOX- BDT-CP-0.5GPM-MLM-IR-FCT HARDWIRED FAUCET WITH LOW VOLTAGE TRANSFORMER, ANGLE STOPS, SUPPLIES, ' P' TRAP, AND POP UP WASTE. PROVIDE WITH WALL CARRIER.ELKAY # LRAD221955 WITH SYMMONS #SPP-3510 FAUCET, 1.5 GPM.KS-
1 KITCHEN SINK 1 1/21/21/21 1/22ELKAY #ECTSRAD33226TBG WITH KOHLER #K-77515 FAUCET WITH PULL-DOWN SPRAY, 1.5 GPM.SH- 1 SHOWER (ADA)21/21/21 1/22EWS-
1 EMERGENCY
EYE WASH/
SHOWER ----1
1/4 ----GUARDIAN #GBF1909PCC DF-
1 DRINKING
FOUNTAIN/
BOTTLE FILLING STATION
1/
2 1 1/411/22--PARK WAREHOUSE RECESSED WALL MOUNTED WATER BOTTLE FILLER STATION.ELKAY # EFS2523C, WITH CHICAGO FAUCETS #897-CCP WALL MOUNTED FAUCET.SWANSTONE SHOWER PAN #SBF-3464 WITH SYMMONS #C961TRMTC ONE-HANDLE SHOWER SYSTEM WITH TRIM AND SYMMONS #C-96-500-B30-VX ADA HAND SHOWER WITH SLIDE BAR. CONFIRM SHOWER FINISH WITH ARCHITECTURAL. WB-
1 WASHER BOX 21/21/21 1/22SYMMONS LAUNDRY-MATE #W-602 HB- 2 HOSE BIBB 3/4 --------ACORN#
8121-LF WITH VACUUM BREAKER ACORN#
8151 WITH VACUUM BREAKER FD-
1 FLOOR DRAIN 1 1/2 22----RD-
1 ORD-
1 ROOF
DRAIN OVERFLOW
DRAIN ----------ZURN #Z164, COMBINATION ROOF AND OVERFLOW DRAIN. PROVIDE WITH DOWNPOUT NOZZLE.JAY R. SMITH #2005Y ZURN
XT-35, WATER THERMAL EXPANSION TANK, CARBON STEEL OUTER SHELL WITH EPOXY FINISH, BUTYL RUBBER DIAPHRAGM, FACTORY PRE-CHARGE 40 PSI.GD
1 GARBAGE
DISPOSAL ----120 1 60 3/4 15 INSINKERATOR
BADGER 5XP WITH J BOX BELOW COUNTER AND SWITCH ABOVE COUNTER SH-
2 SHOWER (STANDARD)21/21/21 1/22SWANSTONE
SHOWER PAN #SS-3232 WITH SYMMONS #C961TRMTC ONE-HANDLE SHOWER SYSTEM WITH TRIM.
CONFIRM SHOWER FINISH WITH ARCHITECTURAL. RR-
1 ROOF RECEPTOR 1 1/2 22----JAY R. SMITH #3960Y 2
1/2"G 649
CFH 2"
G 569
CFH CLOTHES
DRYER 80
CFH 1"
G 80
CFH WATER
HEATER 199
CFH 1
1/4"G 199
CFH BBQ
GRILL 70
CFH 1"
G 70
CFH HHW
BOILER 300
CFH11/2"G 300
CFH 2"
G 370
CFH GAS
SHUT OFF VALVE. TOTAL DEVELOPED LENGTH INSIDE BUILDING = 130' MAX..SEDIMENT TRAP PER 1212.
9, 2019 CPC (TYP)FS-
1 FLOOR SINK 1 1/2 22----JAY R. SMITH #320-Y02 WC-
2 WATER CLOSET (ADA)1 1/4 24--INT SLOAN #
WETS-2450.1303, ELONGATED VITROUS CHINA BOWL, SIPHON JET, FLUSH VALVE, ELECTRONIC HARD WIRED SENSOR WITH LOW VOLTAGE TRANSFORMER, 1.28 GPF MAXIMUM. PROVIDE WITH WALL CARRIER INSTALLED TO BE ADA COMPLIANT.HB-
3 HOSE BIBB (SPIGOT)3/4 --------SPEAKMAN #
SC-5912-IS-SCV, HOSE BIBB AND SPRAY ASSEMBLY, 69" VINYL REINFORCED HOSE, INSULATED HANDLE, SPRAY OUTLET AND WALL HOOK, INTEGRAL VACUUM BREAKER, SAFE CLOSING VALVE ON HANDLE.
No.
30090 O
A
O
C
LER
ETS
EM AT
E
ETSGIGGDUUOO RPD
NESIRS FICLFA
GI
AACANHIINL
ORAA
SKEEN OIFESSN
ALR
R Description:
Date: Project
Number:Drawn
By:Checked
By:Sheet
Title:Approved
By:ISSUED
FOR CONSTRUCTION
BLDG
DEPT SUBMITTAL
09/
02/ 20 BLDG
DEPT RESUBMITTAL
BID
SET 11/
25/ 20 PROJECT:
6353
DEL CERRO BLVD., SAN DIEGO, CA 92120 619.
698.9177 | www.jeffkatzarchitecture.com PROJECT
No.: 4560 PLUMBING
SCHEDULES
200102
P0.
2 AC
DI
AC
ADMINISTRATION
BUILDING
CITY
OF VISTA PUBLIC WORKS
DEPARTMENT 1165
E TAYLOR ST.VISTA,
CA 92084 02/
11/ 21 FOR
CONSTRUCTION
05/
18/ 21
11/10/2026 C6 299 of 357
11 10
8 ADMINISTRATION BUILDING
PATIO
E TAYLOR
ST.
POC 4"S
I.E.= 527.8'
POC 2"CW
I.E.= 525.18''
POC 4"SD
I.E.= 528.8'
POC 4"SD
I.E.= 528.8'POC 4"SD
I.E.= 528.8'
POC 4"SD
I.E.= 528.8'
POC 4"SD
I.E.= 528.8'
POC 4"SD
I.E.= 528.8'
2 1/2"G, B/G
POC 2 1/2"G
CONNECT TO EXISTING GAS PIPING ON SITE
CONTRACTOR SHALL FIELD VERIFY LOCATION AND
ELEVATION OF EXISTING GAS PIPING PRIOR TO INSTALLATION
FFE = 530.8'
No. 30090
O
A
O
C
LER
ETS EM
AT
EETSGI GGDUUOO
RPD NESIRS
FICLFA
GI
AACANHIINLOR
AASK EEN
OIFESSNAL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
PLUMBING SITE
PLAN
200102
P1.0
AC
DI
AC
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE: 1" = 10'-0"P1.0
1 PLUMBING SITE PLAN
02/ 11/ 21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 300 of 357
BREAK ROOM
125
LOBBY
100
SERVER
118
OFFICE D1
119
OFFICE D1
120
MULTI-PURPOSE
112
RECEPTION
103
STORAGE
114
RECEIVING
116
OPEN WORK
STATIONS
117
COPY/MAIL
ROOM
115
WOMEN'S
128
OFFICE B
107
HALL
102
RESTROOM
104
CONFERENCE
106
RESTROOM
101
COPY
105
HWH
127
ELECTRICAL
132
MEN'S
129
OFFICE D1
121
MEN'S LOCKER
130
WASH ROOM
131
STORAGE
123
HALL
122
FITNESS
126
JAN
124
OFFICE D1
111
OFFICE C1
108
OFFICE C1
110
OFFICE C1
109
STORAGE
113
FR
133
OFFICE E1
134
OFFICE E1
135
OFFICE E1
136
OFFICE E1
137
OFFICE E1
138
OFFICE E1
139
OFFICE E1
140
2 J
G
L
H
K
103
C
A
119864131
B
5 7
D
F
E
12 POC 4"S
HB-2
HB-2
POC 2"CW
14 L-1
L-1
L-1
MS-1
FD-1
SH-2
SH-1
U-1 U-1 U-1
WC-2 WC-1 WC-1 WC-1 WC-1
L-2
L-2
L-2
FS-1
WC-2
WC-1
SH-1
L-1
L-1
KS-1
S-1
GD
1 WH
1 CP
1 ET
1 POC 4"SD
POC 4"SD
POC 4"SD
4" SD & OSD, UP
2090 SF)
4"SD
4"OD
4"SD, DN
4"OD, DN
4" SD & OSD, UP
1366 SF)
4"SD, DN
4"OD, DN
POC 4"SD
4" SD & OSD, UP
2405 SF)
4"OD
4"SD
4"OD, DN
4"SD, DN
POC 4"SD
4" SD & OSD, UP
2090 SF)
4"OD
4"SD
4"SD, DN
HB-2
WCO
DF-1
DF-1
POC 4"SD
4" SD & OSD, UP
138 SF)
4"OD, DN
4"SD, DN
7 115
2 2 2
9 FD-1
FD-1
FD-1
L-2
WC-2
L-2
WC-2
FD-1
FD-1
FD-1
FD-1
8 8
2 2
2 2
2 1
1 1
1 1
1 1
1 1
1 1
3 EWS-1
WCO
WCO
WCO
WCO
WCO
WCO
WCO
WCO
6 1
2 10
6 3/4"CDWB-1
4" SD & OSD, UP
2202 SF)4"SD
4"OD4"OD, DN
4"SD, DN
MV
1 2 1/2"G
3/4"CW
3/4"HWR
3/4"HW
1 1/2"CW
12 13
13 HB-3
4 1
1 1/4"CW
1 1/4"CW
FS-1
WCO
WCO
WCO
FD-1
No. 30090
O
A
O
C
LER
ETS EM
AT
EETSGI GGDUUOO
RPD NESIRS
FICLFA
GI
AACANHIINLOR
AASK EEN
OIFESSNAL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
PLUMBING
FLOOR PLAN
200102
P2.1
AC
DI
AC
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE: 1/8" = 1'-0"P2.1
1 PLUMBING FLOOR PLAN
KEYNOTES
GENERAL NOTES
X
1. 1/2" TRAP PRIMER BELOW FLOOR SEE DETAIL 1 / P5.1
2.SHUT OFF VALVES ABOVE CEILING WITH ACCESS PANEL
3. 1/2"COLD WATER STUB OUT TO ICE MACHINE
4.ICE MAKER BY OTHERS.
5. 1/2"COLD WATER STUB OUT TO REFRIGERATORS
6. 3/4"COLD WATER UP TO HOSE BIBB ON ROOF
7.LOW PRESSURE GAS UP TO HHW BOILER ON ROOF
8. 2"SEWER UP TO ROOF RECEPTOR RR-1
9. 3/4" CONDENSATE DOWN TO DISCHARGE TO HOUSE SIDE OF LAVATORY P-TRAP
10.LOW PRESSURE GAS DOWN TO BBQ
11.1"COLD WATER UP, MAKE-UP WATER TO HHW BOILER ON ROOF
12.FOR SINK DETAIL SEE 2 / P5.1.
13.CONTRACTOR SHALL INSTALL PIPING VERTICALLY MOUNTED TO CORRIDOR STUDS OR OTHERWISE IN ORDER TO AVOID CONFLICT WITH SOLATUBES.
1.FOR WASTE AND VENT SIZING AND ROUTING SEE PLUMBING WASTE AND VENT RISER DIAGRAM ON SHEET P4.1.
2.FOR GAS PIPE SIZES SEE GAS RISER DIAGRAM 1 / P2.0.
02/ 11/ 21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 301 of 357
2 J
G
L
H
K
C
A
119864131
B
5 D
F
E
1214
RD-1 / ORD-1
2090 SF)
RD-1 / ORD-1
2405 SF)
RD-1 / ORD-1
2090 SF)
RD-1 / ORD-1
1366 SF)
2" VTR
2" VTR
2" VTR
1 1/2" VTR
1 1/2" VTR
2" VTR
1 1/2" VTR
1 1/2" VTR
HB-1
HB-1
RD-1 / ORD-1
138 SF)
1 1/2" VTR
RR-1
RR-1
2 1
1 1/2" VTR
RD-1 / ORD-1
2202 SF)
2" VTR
No. 30090
O
A
O
C
LER
ETS EM
AT
EETSGI GGDUUOO
RPD NESIRS
FICLFA
GI
AACANHIINLOR
AASK EEN
OIFESSNAL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
PLUMBING
ROOF PLAN
200102
P2.2
AC
DI
AC
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE: 1/8" = 1'-0"P2.2
1 PLUMBING ROOF PLAN
KEYNOTES
GENERAL NOTES
X
1. 1" COLD WATER WITH SHUTOFF VALVE AND BACKFLOW PREVENTER. MAKE-UP WATER TO BOILER.
2. 1 1/2" LOW PRESSURE GAS TO BOILER FOR GAS PIPING DIAGRAM SEE 1 / P0.2.
1.FOR WASTE AND VENT SIZING AND ROUTING SEE PLUMBING WASTE AND VENT RISER DIAGRAM ON SHEET P4.1.
02/ 11/ 21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 302 of 357
WOMEN'S
128
HWH
127
ELECTRICAL
132
MEN'S
129
OFFICE D1
121
MEN'S LOCKER
130
WASH ROOM
131
HALL
122
FITNESS
126
JAN
124
2 J
G
H
C
645
D
F
E
SH-1
WC-1
WC-2
L-1
L-1
FS-1
L-2
FD-1
L-2
L-2
WC-2 WC-1 WC-1 WC-1 WC-1
FD-1
U-1 U-1 U-1
FD-1
FD-1
L-1
L-1
L-1
FD-1
FD-1
SH-1
SH-2
FD-1
MS-1
FD-1
WB-1
HB-2
1 1
1 1
1 1
1 1
1 1/2"HW
1/2"CW
1 1/2"CW
1 1/2"CW 1 1/2"CW
1/2"CW
1/2"HW
1/2"HW
1/2"CW
1/2"HW
1/2"CW
1/2"CW
3/4"HW
1 1/2"CW
3/4"HWR
1 1/2"HW
1 1/2"CW 2"CW
1 1/2"HW
3/4"HWR
2"CW 2"CW
1 1/2"HW
3/4"HWR
3/4"HW
2"CW
3/4"CW
1 1/2"CW 2"CW11/2"CW
2"CW
2"CW
2"CW
1"CW
1"CW3/4"CW3/4"CW
1"CW
3/4"HW
3/4"CW
3/4"HW
1/2"HW
1/2"CW
3/4"HW
3/4"CW
1/2"CW
1 1/4"CW
1 1/4"CW
1"HW
2"CW
1 1/2"HW
2"CW
3/4"CW
3/4"HW
3/4"CW
3/4"CW
1/2"HW
1/2"HW
3/4"CW
3/4"CW
1/2"HW
1/2"CW
EWS-1
HB-3
FS-1
LOBBY
100
RECEPTION
103
RECEIVING
116
RESTROOM
104
RESTROOM
101
COPY
105
STORAGE
113
10119
D
F
E
WC-2
L-2
L-2
WC-2
FD-1FD-1
3/4"HW
1 1/2"CW
3/4"HW
1 1/2"CW
1/2"HW
3/4"HWR
1 1/2"CW
1/2"HW
1 1/2"CW
3/4"CW
3/4"CW
1 1/2"CW
3/4"HW
3/4"CW
1/2"HW11/2"CW
1 1/2"CW
1/2"CW& HW TOLAVATORY11/2"CW
1/2"CW&HW TO LAVATORY
S-1
No. 30090
O
A
O
C
LER
ETS EM
AT
EETSGI GGDUUOO
RPD NESIRS
FICLFA
GI
AACANHIINLOR
AASK EEN
OIFESSNAL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
PLUMBING
ENLARGED
VIEWS
200102
P3.1
AC
DI
AC
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE: 1/ 4" = 1'-0"P3.1
1 PLUMBING ENLARGED PLAN - RR WATER & GAS
SCALE: 1/4" = 1'-0"P3.1
2 PLUMBING ENLARGED PLAN - SINGLE RR WATER & GAS
KEYNOTES
GENERAL NOTES
X
1. 1/2" TRAP PRIMER BELOW FLOOR SEE DETAIL 1 / P5.1
1.FOR GAS PIPE SIZES SEE GAS RISER DIAGRAM 1 / P2.0.
02/ 11/ 21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 303 of 357
WOMEN'S
128
HWH
127
ELECTRICAL
132
MEN'S
129
OFFICE D1
121
MEN'S LOCKER
130
WASH ROOM
131
HALL
122
FITNESS
126
JAN
124
2 J
G
H
C
645
D
F
E
SH-1
WC-1
WC-2
L-1
L-1
FS-1
WC-1
L-2
L-2
L-2
FD-1
WC-2 WC-1
FD-1
WC-1 WC-1
U-1 U-1 U-1
L-1
L-1
L-1
FD-1
MS-1
SH-1
SH-2
FD-1
FD-1
FD-1
FD-1
WB-1
FD-1
EWS-1
FS-1
LOBBY
100
RECEPTION
103
RECEIVING
116
RESTROOM
104
RESTROOM
101
COPY
105
STORAGE
113
10119
D
F
E
WC-2 L-2
L-2
WC-2
FD-1FD-1
WCO S-1
No. 30090
O
A
O
C
LER
ETS EM
AT
EETSGI GGDUUOO
RPD NESIRS
FICLFA
GI
AACANHIINLOR
AASK EEN
OIFESSNAL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
PLUMBING
ENLARGED
VIEWS
200102
P3.2
AC
DI
AC
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE: 1/ 4" = 1'-0"P3.2
1 PLUMBING ENLARGED PLAN - RR WASTE & VENT
SCALE: 1/4" = 1'-0"P3.2
2 PLUMBING ENLARGED PLAN - SINGLE RR WASTE & VENT
KEYNOTES
GENERAL NOTES
X
1.--
1.FOR WASTE AND VENT SIZING AND ROUTING SEE PLUMBING WASTE AND VENT RISER DIAGRAM ON SHEET P4.1.
02/ 11/ 21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 304 of 357
S-1
1 1/2"VTR
2"VTR
L-2
WC-1FD-1
RR-1L-2
WC-1
FD-1 WCO
WCO
WCO
WCO
WCO
FD-1
1 1/2"VTR
WCO
1 1/2"VTR
WCO
DF-1
KS-1
WCO
RR-1
1 1/2"VTR
1 1/2"VTR
WCO
WCO
SH-1
SH-2
FD-1
FD-1
L-1
L-1
L-1
FD-1
MS-1
2"VTR
2"VTR
FD-1
WCO
WCO
FD-1
FD-1
WCO
WCO
WCO
U-1
U-1
U-1
2"VTR
FD-1
WCO
WC-2
WC-1
WC-1
WC-1
WC-1
WCO
FS-1
WCO
WCO
WCO
SH-1
FD-1
WC-1
WC-2
2"VTR
WCO
L-1
L-1
DF-1
WCO
2"S
1 1/2"V
4"S
4"S
1 1/2"V
2"V
1 1/2"VTR
2"V
2"V
4"S
4"S
4"S
2"S
2"S
2"V
2"S
2"V
4"S
4"S
2"S
2"S
4"S
4"S
4"S
2"S
2"S
1 1/2"V
1 1/2"V
2"S2"S
4"S
2"S
4"S
4"S
4"S
2"S
4"S
4"S
4"S
2"S
2"S
2"S
2"S
2"S
2"S
2"S
1 1/2"V
4"S
2"S
2"S
2"S
1 1/2"V
1 1/2"V
2"S
2"S
2"S
1 1/2"V
1 1/2"V
1 1/2"V
1 1/2"V
1 1/2"V
3"S
3"S
2"S
3"S
1 1/2"V
1 1/2"V
4"S
2"S
4"S
2"S
4"S
2"S
1 1/2"V
1 1/2"V
1 1/2"V
1 1/2"V
1 1/2"V
2"V
2"V
2"V
1 1/2"V11/2"V
2"S
4"S
4"S
4"S
4"S 2"S
4"S
2"S
2"S
WB-1
L-2
L-2
L-2
2"S
1 1/2"V
FS-1
WCO
WCO
No. 30090
O
A
O
C
LER
ETS EM
AT
EETSGI GGDUUOO
RPD NESIRS
FICLFA
GI
AACANHIINLOR
AASK EEN
OIFESSNAL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
PLUMBING
RISER
DIAGRAMS
200102
P4.1
AC
DI
AC
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:P4.1
1 PLUMBING WASTE AND VENT RISER DIAGRAM
02/ 11/ 21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 305 of 357
RD-1/OD-1
4"OD
4"SD
4"OD
4"SD
4"OD
4"SD
4"SD
4"OD
RD-1/OD-1
RD-1/OD-1
RD-1/OD-1
RD-1/OD-1
RD-1/OD-1
4"SD
4"OD
4"SD
4"OD
No. 30090
O
A
O
C
LER
ETS EM
AT
EETSGI GGDUUOO
RPD NESIRS
FICLFA
GI
AACANHIINLOR
AASK EEN
OIFESSNAL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
PLUMBING
RISER
DIAGRAMS
200102
P4.2
AC
DI
AC
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:P4.2
1 PLUMBING STORM DRAIN RISER DIAGRAM
02/ 11/ 21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 306 of 357
NO SCALE
NO SCALE
NO SCALE
1 P5.1
2 P5.1
3 P5.1
VENT PIPE THRU ROOF
COUNTERFLASHING
SLEEVE
SEAMLESS LEAD
FLASHING WITH STEEL
REINFORCED BOOT
STONEMAN" OR EQUAL)
BUILT-UP ROOFING
OVER FLANGE, BY
ROOF ASSEMBLY. (SEE
ARCHITECTURAL PLANS
FOR EXACT TYPE OF
CONSTRUCTION)
ROOFING CONTRACTOR
HEIGHT AS REQ'D
BY CODE
NOTE: IF THIS DETAIL DIFFERS FROM THAT
SHOWN ON THE ARCHITECTURAL PLANS,
THE ARCHITECTURAL DETAIL SHALL BE
FOLLOWED
HVAC AIR INTAKE
15' MIN
TRAP PRIMER DETAIL
KITCHEN SINK DETAIL
TYPICAL VENT THRU ROOF DETAIL
AIRGAP FITTING
GLASS FILLER
HOSE SPRAY
GF
1 DISHWASHER
BY OTHERS.
COUNTER TOP
SINGLE LEVER FAUCET
FLEXIBLE CONNECTION (TYPICAL)
KS-1
1/2"COLD WATER
ANGLE STOP (TYPICAL)
SUPPLY CONNECT
TO COFFEE MAKER
BALL VALVE (TYPICAL)
1/2"COLD WATER
CONNECTION TO
ICE MAKER IN
REFRIGERATOR
WALL CLEANOUT
P"TRAP
FINISHED FLOOR
UNION (TYPICAL)
GD
1 TO DISHWASHER
1/2"HOT WATER CONNECT
1/2"COLD WATER WITH
CAPPED BALL VALVE
FOR CONNECTION TO
FUTURE WATER FILTER
CONNECT DRAIN FROM
DISHWASHER TO GD-1
VIA AIRGAP FITTING
SUPPLY (SEE PLAN)
NEAREST COLD WATER
1/2'' COLD WATER FROM
DISTRIBUTION BOX
FOR THREE OR MORE
WITH ACCESS PANEL
TRAP PRIMER LOCATIONS.
SEE PLANS FOR PIPE, FLOOR SINK, AND
SLOPE
PRIME RITE BY PPP
TRAP PRIMER VALVE
WASTE TO
SYSTEM
VENTED
TRAP
NOTE:
FLOOR DRAIN
OR SINK
CONNECTIONS.
UNION (TYPICAL)
SHUT-OFF VALVE
FINISHED
FLOOR
No. 30090
O
A
O
C
LER
ETS EM
AT
EETSGI GGDUUOO
RPD NESIRS
FICLFA
GI
AACANHIINLOR
AASK EEN
OIFESSNAL
R R
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
ISSUED FOR
CONSTRUCTION
BLDG DEPT
SUBMITTAL
09/ 02/ 20
BLDG DEPT
RESUBMITTAL
BID SET
11/ 25/ 20
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
PROJECT No.: 4560
PLUMBING
DETAILS
200102
P5.1
AC
DI
AC
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
02/ 11/ 21
FOR
CONSTRUCTION
05/ 18/21
11/10/2026 C6 307 of 357
OHP
T
J
M
PC
DS
LCP
DETAIL NUMBER DESIGNATION
SHEET ON WHICH DETAIL IS LOCATED
E1
3 SHEET NOTEREFERENCE1
M
M
SITE SYMBOLS LEGEND
CIRCUIT BREAKER CALLOUT
FUSE CALLOUT
TRIP SIZE
POLE
FUSE SIZE
POLE
NON-FUSIBLE DISCONNECT SWITCH (RATINGS AS NOTED)
FUSIBLE DISCONNECT SWITCH (RATINGS AS NOTED)
T
MOTOR
GROUND
CIRCUIT BREAKER
GFP
SPD SURGE PROTECTION DEVICE
GROUND FAULT PROTECTION
ENCLOSED CIRCUIT BREAKER
SINGLE LINE LEGEND
TC TIME CLOCK
KILOWATT-HOUR METER
FUSED SWITCH
MOTOR STARTER (NEMA SIZE AS NOTED)
CB
AUTOMATIC TRANSFER SWITCH
PANEL BOARD
2 2
PANEL BOARD (SURFACE)
SWITCHBOARD OR MCC
POWER LEGEND
PANEL BOARD (FLUSH)
LOW VOLTAGE PANEL
LIGHTING CONTROL PANEL
LIGHTING LEGEND
OCCUPANCY SENSOR -CEILING MOUNTED.
PHOTOCELL -CEILING OR ROOF MOUNTED.
DAYLIGHT SENSOR -CEILING MOUNTED.
GRAPHICAL LOW VOLTAGE SWITCH.LV
ELECTRICAL ABBREVIATIONS
GENERAL NOTES
M EXTERNALLY MOUNTED METER
175
3 150
3 CONDUIT STUBOUT
CONDUIT RISING UP
CONDUIT DROP DOWN
8 CONDUIT CONCEALED IN FLOOR, UNDERFLOOR,
CONDUIT CONCEALED IN WALLS OR CEILING.
CONDUIT RUN EXPOSED
OR BELOW GRADE
FLEXIBLE CONDUIT
HOMERUN TO PANEL AND CIRCUITS INDICATED. NUMBER
ADJACENT TO CIRCUIT DENOTES WIRE SIZE OTHER THAN #
12 FOR ALL
CONDUCTORS UNO.
GENERAL SYMBOLS LEGEND
A-1
M
TYPICAL
DESIGNATIONS TO
BE USED IN
CONJUNCTION WITH
CONDUIT SYMBOLS
NEW CONDUIT AND/OR CONDUCTOR LINE. SEE BELOW
FOR TYPICAL DESIGNATIONS
TOGGLE TYPE FRACTIONAL HP MANUAL MOTOR STARTER WITH
THERMAL OVERLOADS (DELETED IF FOR DISCONNECT USE ONLY)
AND HANDLE GUARD/LOCK-OFF, 2 POLES (VERIFY WITH BRANCH
CIRCUIT).
COMBINATION FUSIBLE DISCONNECT SWITCH AND MOTOR STARTER, NEMA SIZE AS NOTED), 3P, 600 VAC MAXIMUM RATING.
TRANSFORMER DELTA PRIMARY, WYE SECONDARY WITH kVA RATING EMERGENCY BUG EYE FIXTURE.
SUBSCRIPT ADJACENT TO SWITCH INDICATES:
K = KEYED SWITCH
a,b,c etc. = MULTIPLE SWITCHES/CONTROL LEGS IN A GANGED BOX WITH A COMMON COVER PLATE.
LIGHTING FIXTURES. SEE FIXTURE SCHEDULE FOR
MODEL/PART NUMBERS AND ADDITIONAL DETAILS.
COORDINATE THE EXACT MOUNTING AND LOCATION OF ALL LIGHTING, SUPPORTS AND ALL CONDUITS WITH OTHER TRADES PRIOR TO ROUGH-IN. SEE ARCH PLANS FOR EXACT GRID, FLUSH AND SURFACE MOUNTING LOCATIONS.
LUMINAIRE(S) POLE MOUNTED WITH ARM. TYPE AS NOTED.
TRANSFORMER
TELEPHONE BACKBOARD. 3/4'' PLYWOOD, LENGTH AND WIDTH
AS NOTED
EPO -EMERGENCY POWER OFF BUTTON
A AMPERES
ADA AMERICANS WITH DISABILITIES ACT
A.F.F.ABOVE FINISHED FLOOR
AIC AMPS INTERRUPTING CURRENT
ALT.ALTERNATE
ATS AUTOMATIC TRANSFER SWITCH
BLDG BUILDING
C CONDUIT
CB CIRCUIT BREAKER
CFCI CONTRACTOR FURNISHED,CONTRACTOR INSTALLED
CFL COMPACT FLUORESCENT LAMP
CKT CIRCUIT
C.O.CONDUIT ONLY
CONC.CONCRETE
CX CONNECT TO EXISTING CIRCUIT
CU COPPER
dBA DECIBELS
DIST.DISTRIBUTION
DWG.DRAWING
EM EMERGENCY BATTERY PACK
ETC ET CETERA
EG EQUIPMENT GROUND
EPO EMERGENCY POWER OFF BUTTON
EWC ELECTRIC WATER COOLER
EXIST. (E)EXISTING
FA FIRE ALARM
FACP FIRE ALARM CONTROL PANEL
FLA FULL LOAD AMPS
GD GARBAGE DISPOSAL
GFI GROUND FAULT INTERRUPTER
GND GROUND
HORIZ.HORIZONTALLY MOUNTED
HP HORSEPOWER
KCMIL THOUSAND CUBIC MILLIMITERS
KVA KILOVOLT-AMPERES
KW KILOWATTS
JB JUNCTION BOX
LTG LIGHTING
MCA MINIMUM CIRCUIT AMPS
S
M M
COMBINATION VOICE/DATA OUTLET MOUNTED AT 18'' UNO.
PROVIDE 3/4" C.O. TERMINATE IN ACCESSIBLE CEILING W ITH INSULATED BUSHING.
WALL MOUNTED VOICE OUTLET AT +18'' UNO.
PROVIDE 3/4" C.O. TERMINATE IN ACCESSIBLE CEILING W ITH INSULATED BUSHING.
COORDINATE THE EXACT MOUNTING OF ALL CABLE TRAY SUPPORTS AND ALL CONDUITS WITH OTHER TRADES PRIOR TO ROUGH-IN.
12'' WIDE MONO-TRAY, 4'' DEEP (NOMINAL), 6'' RUNG SPACING.
TYPICAL UNO
12'' WIDE CABLE TRAY, 4'' DEEP (NOMINAL) TYPICAL UNO
COMMUNICATION LEGEND
WALL MOUNTED DATA OUTLET AT +18'' UNO.
PROVIDE 3/4" C.O. TERMINATE IN ACCESSIBLE CEILING W ITH INSULATED BUSHING.
CEILING MOUNTED DATA OR VOICE/DATA OUTLET.
WALL OR FLOOR VOICE/DATA CONNECTION TO MODULAR
FURNITURE. VERIFY EXACT LOCATION WITH FURNITURE
SUPPLIER.
FLOOR DATA OR VOICE/DATA OUTLET. VERIFY EXACT LOCATION WITH ARCHITECT.
SPEAKER -CEILING MOUNTED
NEW HANDHOLE
NEW MANHOLE
EXISTING MANHOLE
EXISTING MANHOLE
P P
J
D DIMMER SWITCH
D DIMMER/OCCUPANCY SENSOR SWITCH
OCCUPANCY SENSOR SWITCH
S TOGGLE SWITCH
EMERGENCY LIGHTING FIXTURES. SEE FIXTURE SCHEDULE
FOR MODEL/PART NUMBERS AND ADDITIONAL DETAILS.
LUMINAIRE(S) POLE MOUNTED ON TOP. TYPE AS NOTED.
LIGHTED EXIT SIGN. TOP MOUNTED ON CEILING OR STEM MOUNTED.
SHADED SIDE INDICATES FACE. PROVIDE ARROWS TO MATCH
ARCHITECTURAL OR LIFE SAFETY PLANS.
SUBSCRIPT ADJACENT TO LIGHTING FIXTURE INDICATES:
L# =FIXTURE DESIGNATION
1,2,3 etc. = BRANCH CIRCUIT NUMBERS
a,b,c etc. = SWITCH-LEG REFERENCE
NL = NIGHT/SECURITY LIGHTING FIXTURE
LIGHTING LEGEND
COORDINATE THE EXACT MOUNTING AND LOCATION OF ALL LIGHTING, SUPPORTS AND ALL CONDUITS WITH OTHER TRADES PRIOR TO ROUGH-IN. SEE ARCH PLANS FOR EXACT GRID, FLUSH AND SURFACE MOUNTING LOCATIONS.
S #
OHP
OHP EXISTING TO BE DEMOLISHED CONDUIT AND/OR
CONDUCTOR. SEE BELOW FOR TYPICAL DESIGNATIONS
OHPXX X
OHP EXISTING CONDUIT AND/OR CONDUCTOR LINE TO
REMAIN. SEE BELOW FOR TYPICAL DESIGNATIONS
OHP
UP - UNDERGROUND PRIMARY
US - UNDERGROUND SECONDARY
UC - UNDERGROUND COMMUNICATIONS
USL - UNDERGROUND STREET LIGHTING
OHP - OVERHEAD PRIMARY
OHS - OVERHEAD SECONDARY
OHC - OVERHEAD COMMUNICATIONS
NEW TRANSFORMER EXISTINGTRANSFORMERTT
NEW MV SWITCH EXISTING MVSWITCHSWSW
NEW OH POLE EXISTING OH POLE
NEW OH TRANSFORMER EXISTING OH TRANSFORMER
DUPLEX QUAD DUPLEX
GFI
QUAD
GFI
DUPLEX
WITH USB
RECEPTACLE, NON-LOCKING TYPE, GROUNDING, 120V -20A.
MOUNTED AT +18 AFF UNO. SHADED REPRESENTS ABOVE
COUNTER OR +42" AFF.
DUPLEX QUAD DUPLEX
GFI
QUAD
GFI
DUPLEX
WITH USB
CONTROLLED RECEPTACLE NON-LOCKING TYPE 120V-20A. CONTROLLED RECEPTACLE SHALL BE HALF HOT. TO BE LOCATED WITHIN 6' OF AN UNCONTROLLED RECEPTACLE. CONNECT SWITCH LEG BETWEEN RELAY POWER PACK AND OCCUPANCY CONTROLS FOR AUTOMATIC SHUT OFF. CONTROLLED
RECEPTACLES SHALL HAVE PERMANENT MARKING TO DIFFERENTIATE THEM FROM UNCONTROLLED RECEPTACLES. (CEC TITLE 24 SECTION 130.5(D)).
PROVIDE FACEPLATE PER NEC 406.3(E).
CEILING MOUNTED DUPLEX OR QUAD RECEPTACLE,
NON-LOCKING TYPE, GROUNDING.
POWER FLOOR BOX.
WALL OR FLOOR POWER CONNECTION TO MODULAR FURNITURE.
VERIFY EXACT LOCATION WITH FURNITURE SUPPLIER.
JUNCTION BOX
WALL MOUNTED JUNCTION BOX
EQUIPMENT SIZES SHOWN ON PLANS ARE NOT EXACT. CONTRACTOR IS RESPONSIBLE FOR ENSURING EQUIPMENT CLEARANCES ARE MET BASED ON ACTUAL SIZE.
COORDINATE THE EXACT MOUNTING AND LOCATION OF ALL W IRING DEVICES AND ALL CONDUITS WITH OTHER TRADES PRIOR TO ROUGH-IN. SEE ARCH PLANS FOR EXACT DEVICE LOCATIONS.
SPECIAL NEMA CONFIGURATION RECEPTACLE MOUNTED AT +18"
AFF UNO. SEE FLOOR PLANS FOR CONFIGURATION.
CEILING MOUNTED SPECIAL NEMA CONFIGURATION RECEPTACLE
MOUNTED AT +18" AFF UNO. SEE FLOOR PLANS FOR
CONFIGURATION.
1. ALL GROUNDING PER NEC.
2. ELECTRICAL CONTRACTOR TO VERIFY EXACT LOCATION OF RECEPTACLES IN TEL/COM ROOMS PRIOR TO ROUGH-IN.
3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ALL OTHER DOCUMENTATION. COORDINATE WITH ALL OTHER TRADES FOR EQUIPMENT LOCATIONS.
4. COORDINATE WITH ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND MOUNTING HEIGHT OF ALL RECEPTACLES AND DEVICES.
5. COORDINATE WITH EQUIPMENT MANUFACTURER FOR LOCATIONS AND CONNECTIONS.
6. VERIFY ALL MECHANICAL EQUIPMENT LOCATIONS WITH MECHANICAL AND ARCHITECTURAL DRAWINGS PRIOR TO ROUGH-IN.
7. EACH BRANCH CIRCUIT THAT SUPPLIES NON-LINEAR LOADS INCLUDING COMPUTERS, COMMUNICATION RACKS, ETC. MUST HAVE A DEDICATED NEUTRAL.
8. MULTI-WIRE BRANCH CIRCUITS FOR GENERAL LOADS CAN INCLUDE UP TO THREE
PHASE CONDUCTORS WITH A SHARED NEUTRAL IN A RACEWAY IF A MULTI-POLE
BREAKER IS PROVIDED TO SIMULTANEOUS DISCONNECT ALL SINGLE POLE
CIRCUIT BREAKERS THAT SUPPLY INDIVIDUAL PHASE CONDUCTORS OF THE MULTI-WIRE CIRCUIT.
9. ALL WORK SHALL BE PERFORMED UNDER CEC 2019.
SINGLE LINE LEGEND
MCC MOTOR CONTROL CENTER
MEP MECHANICAL, ELECTRICAL, PLUMBING
MIC MICROWAVE
MIN MINIMUM
MOP MAXIMUM OVERCURRENT PROTECTION
MTD MOUNTED
MTG. HT.MOUNTING HEIGHT
NIC NOT IN CONTRACT
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NL NIGHT LIGHT
NTS NOT TO SCALE
OC ON CENTER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
P POLE
PB PULL BOX
PH PHASE
PIV POST INDICATOR VALVE
PNL PANEL
POC POINT OF CONNECTION
PVC POLYVINYL CHLORIDE
RCP REFLECTED CEILING PLAN
RECEPT RECEPTACLE
REQ'D REQUIRED
RGS RIGID GALVANIZED STEEL
SEC SECURITY
SHT SHEET
S.N.SOLID NEUTRAL
SPD SURGE PROTECTION DEVICE
SS STAINLESS STEEL
SWGR SWITCHGEAR
TC TERMINAL CABINET
TEL TELEPHONE
T.I.TENANT IMPROVEMENT
T.R.TAMPER RESISTANT
TV TELEVISION
TYP TYPICAL
U.C.UNDER COUNTER
UL UNDERWRITERS LABORATORY
U.N.O.UNLESS NOTED OTHERWISE
V VOLTS
WH WATER HEATER
W WATTS
WP WEATHERPROOF
XFMR TRANSFORMER
X EXISTING TO REMAIN
XD EXISTING TO BE DEMOLISHED
XR EXISTING TO BE RELOCATED
XL NEW LOCATION OF EXISTING ITEM
ELECTRICAL ABBREVIATIONS
CARD READER. COORDINATE LOCATION WITH ARCHTIECT.
CR
DL ELECTRONIC DOOR LOCK. COORDINATE LOCATION WITH ARCHITECT.
B DOOR LOCK BUZZER. COORDINATE LOCATION WITH ARCHITECT.
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
LEGENDS
NOTES AND
ABBREVIATIONS
200102
E0.1
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SHEET LIST
SHEET NUMBER SHEET NUMBER
E0.1 LEGENDS NOTES AND ABBREVIATIONS
E0.2 SINGLE LINE DIAGRAM AND CALCULATIONS
E0.3 PANEL SCHEDULES
E1.0 ELECTRICAL SITE PLAN
E2.0 FIRST FLOOR PLAN - POWER
E2.1 FIRST FLOOR PLAN - LIGHTING
E2.2 FIRST FLOOR PLAN - MECH
E3.0 ELECTRICAL ROOF PLAN
E4.1 ELECTRICAL DETAILS
E4.2 ELECTRICAL DETAILS
E4.3 ELECTRICAL DETAILS
E5.1 TITLE 24
E5.2 TITLE 24
E5.3 TITLE 24
PV0.1 ELECTRICAL PV SYMBOLS
PV0.2 ELECTRICAL PV NOTES
PV0.3 ELECTRICAL PV LABELS
PV1.0 SOLAR LAYOUT
PV2.0 PV SINGLE LINE DIAGRAM
PV2.1 DC SCHEMATIC DIAGRAM
PV3.0 PV SPECIFICATIONS
PV4.0 PV CALCULATIONS
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 308 of 357
DEMOLISHED
ADMIN BUILDING
M
M
BUILDING 'B'ADMIN
800
3 G N
EXISTING METER SWITCHBOARD "MSB"
1200A, 208Y120V, 3PH, 4W, NEMA 1, BRACED FOR 42,000kA
225
3 225
3 225
3 200
3 600
3 400
3 BUILDING 'B'
800A, 208Y120V, 3PH, 4W, NEMA 1, BRACED FOR 42,000kA
1200
3 G N
X)
PANEL
BA
200
3 200
3 METER SWITCHBOARD "MSB"
PANEL
P2
200
3 40
3 HVAC
RTU-1
HVAC
B-1
SPACE
1200A, 208Y120V, 3PH, 4W, NEMA 1, BRACED FOR 42,000kA
225
3 225
3 225
3 200
3 600
3 800
3 G N
DISTRIBUTION BOARD "DB1"
NEW SINGLE LINE DIAGRAM
SCALE: NTS
RECONNECT
EXISTING LOADS
IN BUILDING B
GEN
1200A,
208Y120V,
3PH, 4W,
4-POLE
250
3 250
3 X)100KW
GENERATOR
X)
PANEL
C
PANEL
P1
X)
PANEL
BA
DEMO SINGLE LINE DIAGRAM
SCALE: NTS
RECONNECT
EXISTING LOADS
IN BUILDING B
GEN
X)100KW
GENERATOR
X)
PANEL
C
1 1
2 2
3 4
SINGLE LINE KEYED NOTES
KEY VALUE KEYNOTE TEXT
1 PROVIDE JUNCTION BOX TO INTERCEPT AND BACKFEED FROM NEW 'MSB'. 2 PANELS ARE EXISTING TO REMAIN. INTERCEPT AND EXTEND CONDUIT AND CONDUCTORS TO NEW 'MSB' LOCATION.
3 GENERATOR IS EXISTING TO REMAIN. GENERATOR SHALL BE RE-FED FROM NEW RELOACTED 'ATS'.
4 COORDINATE LOCATION OF NEW 'MSB' WITH ARCHITECT PRIOR TO ROUGH IN. SEE SITE PLAN E1.0 FOR MORE INFORMATION.
DEMO GENERAL NOTE:
ALL HATCHED ITEMS ARE EXISTING TO BE REMOVED UNLESS
OTHERWISE LOCATED.
5 5
6 ELECTRICAL CONTRACTOR SHALL COORDINATE WITH SDG&E FOR REMOVAL OF THE EXISTING METER.
XD)
ATS
5 REFER TO GROUNDING DETAIL 2/E4.1.
6 PV DISCONNECT 'UDS2'
600V, 250A WITH VISIBLE
BLADES
7 REFER TO PV SHEETS PV0.1 THRU PV4.0 FOR MORE INFORMATION. 7 PV DISCONNECT 'UDS1'
600V, 250A WITH VISIBLE
BLADES
7 AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
SINGLE LINE
DIAGRAM AND
CALCULATIONS
200102
E0.2
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FEEDER SCHEDULE
DEVICE CALLOUT
100
ATS 1-1/2"C, 3# 1, #1N, #8G
MSB 1-1/2"C, 3# 1, #1N, #6G
225
P1 3"C, 3-4/0, 4/0N, #4G
P2 3"C, 3-4/0, 4/0N, #4G
300
PV-1 3"C, 3-350kcmil, 350kcmil N, #4G
800
DB1 (3)3"C, 3-300kcmil, 300kcmil N, 4/0G
FAULT CURRENT SCHEDULE
DEVICE
FAULT AT
DEVICE AIC RATING VOLTAGE
FEEDER TRANSFORMER
SIZE LENGTH KVA Z%
FAULT AT
PRIMARY
SDG&E 15,873 480V 2/0 100 1.75 UTILITY
MSB 9,425 42000 208V #1 46'
DB1 7,502 42000 208V (3)300kcmil 163'
P1 6,842 30000 208V 4/0 21'
P2 6,780 30000 208V 4/0 24'
PV-1 7,713 42000 208V 350kcmil 51'
VOLTAGE DROP SCHEDULE
DEVICE
FEEDER BRANCH CIRCUIT TOTAL
VOLTAGE
DROP
VOLTAGE
DROP WIRE SIZE MAX VOLTAGE DROP
CIRCUIT
NUMBER WIRE SIZE
DB1 2.96% (3)300kcmil 1.16% 3 3/0 4.12%
P1 3.02% 4/0 1.73% 11 #10 4.75%
P2 3.08% 4/0 1.80% 7 #12 4.88%
PV-1 2.34% 350kcmil 2.34%
LIGHTING FIXTURE SCHEDULE
CALLOUT
Lamp
Color DESCRIPTION MANUFACTURER MODEL Voltage Display VA P1 4000 K DIRECT/INDIRECT LINEAR PENDANT LENGTH: 48' COOPER DSI-WS-50L840-1D-UNV-4-STD-W 120 V 38 W P1E 4000 K DIRECT/INDIRECT LINEAR PENDANT LENGTH: 48'EATON CORELITE DSI-WS-50L840-1D-UNV-4-STD-W-EL14W 120 V 38 W P2 4000 K SURFACE LOOP CIRCULAR CORONET LOOPLED-3-40-LTGC8000-UNV-DB-W-SM 120 V 80 W P2E 4000 K SURFACE LOOP CIRCULAR CORONET SAME AS P2, WITH EM 120V OPTION 120 V 80 W P3 4000 K SQUARE PENDANT EATON SHAPER 147 28 P1S L3/840 UNV MW 40 120 V 19 W R1 4000 K 2X2 RECESSED LED LIGHT EATON CORELITE DRI-WS-5L40-UNV-22-T1-STD 120 V 46 W R1E 4000 K 2X2 RECESSED LED LIGHT EATON CORELITE DRI-WS-5L40-UNV-22-T1-STD-EL14W 120 V 46 W R2 4000 K 2X4 RECESSED LED LIGHT EATON CORELITE DRI-WS-4L40-UNV-24-T1-STD 120 V 36 W R2E 4000 K 2X4 RECESSED LED LIGHT EATON CORELITE DRI-WS-4L40-UNV-24-T1-STD-EL14W 120 V 36 W R3 4000 K 4" LED ROUND DOWNLIGHT HALO HC420-D010-HM412-940-WD 120 V 21 W R4 3000 K 4" LED ROUND DOWNLIGHT, WET LOCATION HALO HC410-D010-HM412-940 120 V 15 W R4E 3000 K 4" LED ROUND DOWNLIGHT, WET LOCATION HALO HC410-D010-REM14-HM412-940 120 V 15 W R5 3000 K RECESSED 4" LINEAR 4' LENGTH NEO RAY S121 DRL240 FES 00481 UDDB 1W 120 V 62 W R5E 3000 K RECESSED 4" LINEAR 4' LENGTH NEO RAY SAME AS R5 WITH EMERGENCY OPTION 'B' 120 V 62 W S1 UNDERCOUNTER LIGHT W/INTEGRATED SWITCH LITHONIA LIGHTING OR EQUAL
UCLD 24IN 90CRI SWR WH
W1 3000 K ROUND WALL SCONCE MGRAW EDISON ISSAF 450LED E1T3 AP 8030 120 V 26 W W2 3000 K EXTERIOR LED WALL MOUNTED GOOSENECK FIXTURE EATON OR EQUAL 303 S1 LEDB2 3000 UNV T2 DIM10 BK 24 120 V 16 W W3 3000 K ROUND WALL SCONCE, 90 DEGREE CUTOFF MGRAW EDISON ISSAF 450LED E1SLL AP 8030 120 V 26 W X1 RED LETTER EXIT SIGN SURE LITE APX7 R 120 V 5 W
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 309 of 357
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
PANEL
SCHEDULES
200102
E0.3
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
Demand Load (A): 65 A
Kitchen Equipment 3950 VA 80.00% 3160 VA Demand Load (kVA): 23552 VA SYSTEM FURNITURE 1440 VA 100.00% 1440 VA
Non-Continuous 3486 VA 100.00% 3486 VA Connected Load (A): 83 A Receptacle 20932 VA 73.89% 15466 VA Connected Load (kVA): 29808 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:79 A 92 A 78 A
Total Load:9471 VA 11012 VA 9325 VA
41 ROOF RECEPTACLES 20 A 1 900 VA 34 VA 1 20 A VAV'S 42 39 BOTTLE FILL 20 A 1 200 VA 1152... 1 20 A FITNESS FANS 40 37 GATE MOTOR 20 A 1 800 VA 720 VA 1 20 A SYSTEM FURNITURE 38 35 DEDICATED IT QUAD 20 A 1 360 VA 720 VA 1 20 A SYSTEM FURNITURE 36 33 DEDICATED IT QUAD 20 A 1 360 VA 900 VA 1 20 A EXTERIOR ICE MACHINE 34 31 DEDICATED IT QUAD 20 A 1 360 VA 350 VA 1 20 A IRRIGATION CONTROLLER 32 29 DEDICATED IT QUAD 20 A 1 360 VA 1080... 1 20 A EXTERIOR RECEPS 30 27 DEDICATED IT QUAD 20 A 1 360 VA 900 VA 1 20 A CONV RECEP 117,120 28 25 COPY ROOM COPIER 20 A 1 350 VA 900 VA 1 20 A CONV RECEP 119,120 26 23 CONV RECEP 112,114 20 A 1 900 VA 900 VA 1 20 A CONV RECEP 115,118,133 24 21 CONV RECEP 109 20 A 1 900 VA 1080... 1 20 A CONV RECEP 113,103,116 22 19 COPIER 20 A 1 350 VA 1200...1 20 A WASHER/DRYER 20
17 CONV RECEP 108,107 20 A 1 1080... 720 VA 1 20 A CONV RECEPS 100,105 18 15 CONV RECEP 110 20 A 1 900 VA 720 VA 1 20 A CONV RECPES 109,108 16 13 BREAKROOM FRIDGE 20 A 1 1200... 900 VA 1 20 A CONV RECEP 111 14 11 BREAKROOM FRIDGE 20 A 1 1200... 350 VA 1 20 A GARBAGE DISPOSAL 12 9 BREAKROOM FRIDGE 20 A 1 1200... 540 VA 1 20 A BREAKROOM CONV RECEPS 10 7 TREADMILL 20 A 1 1 VA 540 VA 1 20 A BREAKROOM CONV RECEPS 8 5 TREADMILL 20 A 1 1 VA 720 VA 1 20 A BREAKROOM CONV RECEPS 6 3 CONV RECEP 122,126,128 20 A 1 900 VA 900 VA 1 20 A CONV RECEP 126,125 4 1 CONV RECEP 130,131,127 20 A 1 900 VA 900 VA 1 20 A CONV RECEP 121,123 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes:
Enclosure:Type 1 MCB Rating:MLO
Mounting:Surface Wires:4 Bus Rating:200
Supply From:DB1 Phases:3 Mains Type:MLO
Location:ELECTRICAL 132 Volts:208/120 - 3Ph/4W A.I.C. Rating:30000 Branch Panel: P1
SYSTEM FURNITURE 6480 VA 100.00% 6480 VA
Lighting - Exterior 118 VA 125.00% 147 VA
HVAC 4118 VA 100.00% 4118 VA
Non-Continuous 2228 VA 100.00% 2228 VA Demand Load (A): 101 A Lighting 6170 VA 125.00% 7713 VA Demand Load (kVA): 36271 VA Spare 825 VA 100.00% 825 VA
Receptacle 5220 VA 100.00% 5220 VA Connected Load (A): 95 A Motor 9040 VA 105.53% 9540 VA Connected Load (kVA): 34199 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:86 A 100 A 103 A
Total Load:10303 VA 11794 VA 12102 VA
41 SPARE 20 A 1 0 VA 667 VA 42
39 SPARE 20 A 1 0 VA 667 VA 40
37 FLUSH VALVES 20 A 1 400 VA 667 VA
3 20 A P-2
38 35 FLUSH VALVES 20 A 1 600 VA 667 VA 36
33 WATER HEATER 20 A 1 700 VA 667 VA 34
31 PUMP P-1 20 A 1 528 VA 667 VA
3 20 A P-1
32 29 CONV RECEPS RM 135,134 20 A 1 720 VA 2059...30
27 CONV RECEPS RM 136,135 20 A 1 900 VA 2059...
2 30 A HVAC CU-1
28 25 CONV RECEPS RM 137,136 20 A 1 900 VA 1584...1 20 A EF-6,7,8 26 23 CONV RECEPS RM 138,137 20 A 1 900 VA 1752... 1 20 A EF-3,4,5 24 21 CONV RECEPS RM 117,140 20 A 1 900 VA 1704... 1 20 A EF-1,2 22 19 CONV RECEPS RM 139,138 20 A 1 900 VA 508 VA 1 20 A RM 134,135,136,137,138,139,140 20 17 SYSTEM FURNITURE 20 A 1 720 VA 500 VA 1 20 A FACP 18 15 SYSTEM FURNITURE 20 A 1 720 VA 325 VA 1 20 A LIGHTING CONTROL PANEL (LCP) 16 13 SYSTEM FURNITURE 20 A 1 720 VA 255 VA 1 20 A RM 133,118,119,120 14 11 SYSTEM FURNITURE 20 A 1 720 VA 1002... 1 20 A RM 117 LTG 12 9 SYSTEM FURNITURE 20 A 1 720 VA 834 VA 1 20 A RM 106,100,101,103,104,113,114,115,116,112... 10 7 SYSTEM FURNITURE 20 A 1 720 VA 1298...1 20 A RM 108,109,110,111,125,102 LTG 8 5 SYSTEM FURNITURE 20 A 1 720 VA 1075... 1 20 A RM 122,127,128,126 LTG 6 3 SYSTEM FURNITURE 20 A 1 720 VA 879 VA 1 20 A RM 121,129,130,131,132 LTG 4 1 SYSTEM FURNITURE 20 A 1 720 VA 437 VA 1 20 A EXTERIOR LIGHTING 2 CKT Circuit Description Trip Poles A B C Poles Trip Circuit Description CKT Notes:
Enclosure:Type 1 MCB Rating:MLO
Mounting:Surface Wires:4 Bus Rating:200
Supply From:DB1 Phases:3 Mains Type:MLO
Location:ELECTRICAL 132 Volts:208/120 - 3Ph/4W A.I.C. Rating:30000 Branch Panel: P2
EQUIPMENT MOTOR 0 VA 0.00% 0 VA
Kitchen Equipment 3950 VA 80.00% 3160 VA
SYSTEM FURNITURE 7920 VA 100.00% 7920 VA
Lighting - Exterior 118 VA 125.00% 147 VA
HVAC 54558 VA 100.00% 54558 VA
Non-Continuous 5714 VA 100.00% 5714 VA Total Deman Load (A):403 A Lighting 6170 VA 125.00% 7713 VA Total Demand Load (kVA):145123 VA Spare 38295 VA 100.00% 38295 VA
Receptacle 26152 VA 69.12% 18076 VA Total Connected Load (A): 422 A Motor 9040 VA 105.53% 9540 VA Total Connected Load (kVA): 151917 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:422 A
Total Conn. Load:151917 VA
12 11
10 9
8 7
6 DB1 (Bldg A)3 100 A 100 A 114447 VA
5 UDS1 (Bldg A)3 300 A 300 A 0 VA
4 C (Bldg A)3 200 A 200 A 29350 VA
3 2
1 BA 3 225 A 225 A 8120 VA
CKT Circuit Description # of Poles Frame Size Trip Rating Load Remarks Notes:
Enclosure:Type 3R MCB Rating:1200
Mounting:Surface Wires:4 Bus Rating:1200
Supply From:SDG&E Phases:3 Mains Type:CB
Location:Volts:208/120 - 3Ph/4W A.I.C. Rating:42000
Switchboard: MSB
EQUIPMENT MOTOR 0 VA 0.00% 0 VA
Kitchen Equipment 3950 VA 80.00% 3160 VA
SYSTEM FURNITURE 7920 VA 100.00% 7920 VA
Lighting - Exterior 118 VA 125.00% 147 VA
HVAC 54558 VA 100.00% 54558 VA
Non-Continuous 5714 VA 100.00% 5714 VA Total Deman Load (A):299 A Lighting 6170 VA 125.00% 7713 VA Total Demand Load (kVA):107653 VA Spare 825 VA 100.00% 825 VA
Receptacle 26152 VA 69.12% 18076 VA Total Connected Load (A): 318 A Motor 9040 VA 105.53% 9540 VA Total Connected Load (kVA): 114447 VA Load Classification Connected Load Demand Factor Estimated Demand Panel Totals Total Amps:318 A
Total Conn. Load:114447 VA
17 16
15 14
13 12
11 10
9 8
7 UDS2 3 250 A 250 A 0 VA
6 BUSSED SPACE -- -- -- 0 VA --
5 BUSSED SPACE -- -- -- 0 VA --
4 HVAC B-1 3 20 A 20 A 2200 VA
3 HVAC RTU-1 3 175 A 175 A 48240 VA
2 P2 3 200 A 200 A 34199 VA
1 P1 3 200 A 200 A 29808 VA
CKT Circuit Description # of Poles Frame Size Trip Rating Load Remarks Notes:
Enclosure:Type 1 MCB Rating:800
Mounting:Surface Wires:4 Bus Rating:800
Supply From:MSB Phases:3 Mains Type:CB
Location:ELECTRICAL 132 Volts:208/120 - 3Ph/4W A.I.C. Rating:42000 Switchboard: DB1
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 310 of 357
CG
CG
CG
CG
CG
CG
J
J
J
J
J
J
J
J
J
CR
CR DL
DL
PR
O
P
E
R
TY
LIN
E
15 SID
E
Y
A
R
D
SE
TB
A
C
K
20' FRONT
YARD
SETBACK
E. TAYLOR
ST.
ADMINISTRATION BUILDING
TOTAL BUILDING AREA: 10,064 S.F.
CONDITIONED SPACE: 9,978 S.F.
EXISTING BUILDING B EXISTING GARAGE
MSB
XD) MSB
BA(X)
ATS
XD) ATS
X)
C
X)
C
X)
C
X)
C
X)
C
X)
C
X)
C
X)
C
1 2
3 4
5 6
7 8
9 SDG&E
NEW PAD AND XFMR 10
11 C(X)
P1 -32
X) GEN
12 13
P1 -37
1"C, 1#8, #8N, #8G
14 8
15 16
16 16
4 17
17 17
17 17
18 19
GENERAL NOTES:
A ELECTRICAL CONTRACTOR TO VERIFY ALL EXISTING FIELD
CONDITIONS.
CONTRACTOR TO VERIFY THE EXISTING CONNECTIONS OF ALL
EXISTING PARKING LIGHTS AND VERIFY NEW CONNECTIONS BACK TO POC.
CONTRACTOR TO COORIDNATE ALL UTILITIES WITH SDG&E.
PRIOR TO COMMENCEMENT OF WORK.
B
C
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
ELECTRICAL SITE
PLAN
200102
E1.0
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:1" = 20'-0"E1.0
1 SITE PLAN
KEYED NOTES
Key Value Keynote Text
1 NEW SWITCHBOARD 'MSB' IN NEMA 3R ENCLOSURE. COORDINATE EXACT PLACEMENT WITH ARCHITECT PRIOR TO ROUGH IN.
2 PROVIDE JBOX FOR POINT OF CONNECTION TO IRRIGATION
CONTROLLER. COORDINATE LOCATION WITH LANDSCAPE PLANS
PRIOR TO ROUGH IN.
3 PROVIDE WEATHER PROOF JUNCTION BOX FOR VEHICULAR GATE MOTOR CONNECTION. COORDINATE EXACT ROUTING WITH
ARCHITECT PRIOR TO ROUGH IN.
4 ( 2)2" C.O FOR FUTURE CHARGING, (1)1-1/2" C FOR GATE, (1)2" C SPARE. COORDINATE ROUTING WITH ARCHITECT PRIOR TO ROUGH IN.
5 PROVIDE NEW ELECTRICAL HANDHOLE WITH DRIVE OVER RATED COVER. COORDINATE PLACEMENT WITH ARCHITECT PRIOR TO
ROUGH IN.
6 PROVIDE HANDHOLE FOR FUTURE EV CHARGING STATION. PROVIDE DRIVE OVER RATED BOX IN PARKING LOT. CAP AND STUB C.O. FOR FUTURE CONNECTION. COORDINATE EXACT PLACEMENT WITH CIVIL AND ARCHITECT PRIOR TO ROUGH IN.
7 EXISTING COMMUNICATIONS HANDHOLE.
8 ( 2)2" COMMUNICATION CONDUIT. COORDINATE CONDUIT
ROUTING WITH ARCHITECT PRIOR TO ROUGH IN.
9 NEW 'ATS' IN NEMA 3R ENCLOSURE. COORDINATE EXACT
PLACEMENT WITH ARCHITECT PRIOR TO ROUGH IN.
10 SDG&E TRANSFORMER AND PAD, INSTALLED PER SDG&E
STANDARDS AND PRACTICES.
11 PROVIDE WEATHERPROOF JUNCTION BOX FOR GATE KEYPAD.
PROVIDE (1)1" C.O. FOR COMMUNICATION CONDUIT FOR GATE
CONTROLLER. COORDINATE LOCATION WITH ARCHITECT PRIOR TO ROUGH IN.
12 PROVIDE 4" C.O. WITH PULL TAPE, COORDINATE AND INSTALL PER SDG&E STANDARDS AND PRACTICES.
13 EXISTING GENERATOR, INTERCEPT AND EXTEND EXISTING CONDUIT AND CONDUCTORS TO NEW ATS LOCATION.
14 PROVIDE NEW COMMUNICATIONS HANDHOLE WITH DRIVE OVER
RATED COVER. SIZE PER COX STANDARDS.
15 EXISTING COMMUNICATION CONDUIT, CONTRACTOR SHALL VERIFY EXACT LOCATION PRIOR TO COMMENCEMENT OF WORK.
16 EXIT AND REVERSE LOOPS BY FENCE CONTRACTOR FOR MOTORIZED GATE, PROVIDE AND INSTALL 3/4"C.O. WITH PULL STRING TO GATE CONTROLLER. COORDINATE
17 PROVIDE JUNCTION BOX WITH 1"C.O. FOR SECURITY CAMERAS.
COORIDNATE EXACT PLACEMENT AND HIEGHT WITH ARCHITECT
PRIOR TO ROUGH IN.
18 EXISTING COMMUNICATION CONDUIT.
19 EXISTING COMMUNICATION VAULT.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 311 of 357
DW
CG
CG
CG
TV
TV
TV
P
M
P
M
P
M
TV
TV
CR
I
P
M
CR
S
CR J
J J
J
CR
CRCR
CR
DL
J
B
JJ
DL
DL
DL
DL
CR
DL
DL
DL
DL
DL
DL
J
J
DL
DLDL
DL
DL
DL DL
CR
CR
CR
CR
CR
CR
CR CR
CR
DL CR
DL
CR
CR
J
J
J
J
J
J
J JJ
J
2 G
E
J
F
H
3 C
A
641
B
5 D
FITNESS
126
BREAK ROOM
125
LOBBY
100
SERVER
118
OFFICE D1
119
OFFICE D1
120
MULTI-PURPOSE
112
RECEPTION
103
STORAGE
114
RECEIVING
116
OPEN WORK
STATIONS
117
COPY/MAIL
ROOM
115
WOMEN'S
128
OFFICE B
107
HALL
102
RESTROOM
104
CONFERENCE
106
RESTROOM
101
COPY
105
HWH
127
ELECTRICAL
132
MEN'S
129
OFFICE D1
121
MEN'S LOCKER
130
WASH ROOM
131
STORAGE
123
HALL
122
JAN
124
OFFICE D1
111
OFFICE C1
108
OFFICE C1
110
OFFICE C1
109
STORAGE
113
WP
WP
WP
P1
P2
WP
WP
FR
133
DB1
1 2
3 7'-0"
ICE
MACHINE
7'-0"
7'-0"
7'-0"
1 1
1 1
P1 -1
2 P1 -2
2 2
2 P1 -3
3 3
3 3
4 P1 -4
3/4"C, 1#10, #10N, #10G
4 4
4 P1 - 7
P1 - 5
P1 - 6
666
GB
P1 -11
3/4"C, 1#10, #10N, #10G
P1 -9
1"C, 1#8, #8N, #8G
P1 -13
3/4"C, 1#8, #8N, #8G
P1 - 8
88 P1 - 10
1010
P1 - 12
14 P1 -14
3/4"C, 1#10, #10N, #10G
1414
14 15
15 15
15 P1 -15
3/4"C, 1#10, #10N, #10G
P1 -16
3/4"C, 1#10, #10N, #10G
16 16
16 P1 -17
3/4"C, 1#8, #8N, #8G
17 17
17 17
17 P1 -18
1"C, 1#8, #8N, #8G
18 18
18 P1 - 19
P1 -20
3/4"C, 1#10, #10N, #10G
P1 -21
3/4"C, 1#8, #8N, #8G
21 21
21 21
P1 -22
1"C, 1#8, #8N, #8G
22 22
22 22
22 23
23 23
23 P1 -23
3/4"C, 1#10, #10N, #10G 24
24 P1 -24
3/4"C, 1#8, #8N, #8G
24 24P1 - 25
P1 -35
P1 -27
P1 -33
P1 -29P1 -31
P1 -26
3/4"C, 1#8, #8N, #8G
26 26
26 26
28 28
P1 -28
3/4"C, 1#10, #10N, #10G
2828
LCP
P1 -30
3/4"C, 1#8, #8N, #8G
30 30
30 30
30 4
P1 -34
P1 -36
3/4"C, 1#10, #10N, #10G
P1 -38
3/4"C, 1#10, #10N, #10G
P2-1,3,5 P2-7,9,11 P2-13,15,17
3/4"C, 1#10, #10N, #10G
FAN
9'-6"
FAN
9'-6"
FAN
9'-6"
FAN
9'-6"
P1 -40
3/4"C, 1#10, #10N, #10G
40 40
40 OFFICE E1
134
OFFICE E1
135
OFFICE E1
136
OFFICE E1
137
OFFICE E1
138
OFFICE E1
139
OFFICE E1
140
3/4"C, 1#10, #10N, #10G
21 P2 -19
19 19
19 19
P2 -21
3/4"C, 1#10, #10N, #10G
21 21
21 P2 -23
23 23
23 23
P2 -25
3/4"C, 1#10, #10N, #10G
25 25
25 25
27 27
27 27
P2 -27
3/4"C, 1#10, #10N, #10G
29 29
29 P2 -29
3/4"C, 1#10, #10N, #10G
BOTTLE FILL
BOTTLE FILL
P-1
7 8 9 10
WATER
HEATER
39 P1 -39
P2 - 31
P2 - 33
5 UDS
DB1 -7
2-1/2"C, 3-250kcmil, 250kcmil N, #4G
6 7
FLUSH
VALVE
FLUSH
VALVE
35 P2 -35
8 8
7'-0"
FUTURE
EQUIP
9 9
FLUSH
VALVE
35 35
35 35
37 37
37 P2 -37
8 8
FLUSH
VALVE
8 FLUSH
VALVE
8 8
8 8
E2.0
2 GENERAL NOTES:
A ELECTRICAL CONTRACTOR TO PROVIDE DIMENSIONED SHOP
DRAWINGS OF ALL ELECTRICAL ROOMS AND PANEL LOCATIONS
PRIOR TO ROUGH IN.
ALL WEATHERPROOF RECEPTACLES SHALL BE EQUIPPED WITH
LOCKABLE COVER.
COORDINATE ALL WALL MOUNTED ELECTRICAL DEVICE
LOCATIONS WITH ADA REQUIREMENTS.
B
C
D ELECTRICAL CONTRACTOR SHALL COORDINATE WITH
CONTROLS/HVAC CONTRACTOR ALL FANS THAT ARE CONTROLLED
VIA ROOM LIGHTING. IF REQUIRED, PROVIDE LOW VOLTAGE
RELAY FOR FAN CONTROL VIA LIGHTING SYSTEM.
E VERIFY MOUNTING HEIGHTS OF ALL DEVICES WITH ARCHITECTURAL ELEVATIONS PRIOR TO ROUGH IN.
F COORDINATE CONTROLLED RECEPTACDLE CONNECTION AND
REQUIREMENTS WITH LIGHTING CONTROL SHOP DRAWINGS.
G COORDINATE POWER FEEDS, LOCATIONS AND WIRING HARNESS
CONFIGURATION WITH FURNITURE VENDOR SHOP DRAWINGS
PRIOR TO ROUGH IN.
H COORDINATE ALL MODULAR FURNITURE MULTI -WIRE WHIPS WITH FURNITURE VENDOR PRIOR TO ELECTRICAL ROUGH IN.
COORDINATE AND PROVIDE ALL REQUIRED POWER PACKS FOR
MODULAR FURNITURE CONTROLLED RECEPTACLES WITH FURNI TURE VENDOR POWER FEEDS.
F
9 10
10 11 11
AN
TON
N A T H A
NSO
N
Exp. 03/31/21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
FIRST FLOOR
PLAN - POWER
200102
E2.0
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:1/8" = 1'-0"E2.0
1 FIRST FLOOR PLAN - POWER
KEYED NOTES
Key Value Keynote Text
1 COORDINATE ALL BREAKROOM ELECTRICAL POWER CONNECTIONS WITH MANUFACTURERS RECOMMENDATIONS. COORDINATE
LOCATIONS OF ALL BREAKROOM DEVICES WITH ARCHITECTS PRIOR TO ROUGH IN.
2 PROVIDE 3/4" THICK FIRE RATED PLYWOOD TELEPHONE
BACKBOARD. FULL HEIGHT ON 3 WALLS, COORDINATE LENGTH WITH CITY OF VISTA PRIOR TO INSTALL.
3 PROVIDE GROUND BUS PER CEC SECTION 250.50, BOND TO
BUILDING GROUNDING ELECTRODE.
4 PROVIDE (1) 1/2" CONDUIT FOR AV.PROVIDE (2) CAT 6 CABLE BETWEEN TV & CONFERENCE TABLE. PROVIDE CAT 6 TO HDMI
CONVERTER WITH 6' HDMI CABLES FOR TV CONNECTION AND USER CONNECTION.
5 PROVIDE WALL MOUNTED SWITCH FOR DOOR LOCK DEACTIVATION IN RECEPTION AREA. COORDINATE EXACT PLACEMENT WITH
ARCHITECT PRIOR TO ROUGH IN.
6 PROVIDE LV POWER SUPPLY ABOVE RECEPTION AREA FOR THE
CARD READERS. PROVIDE CONDUIT FOR POWER SUPPLY TO EACH
DOOR FOR THE LV WIRING. PROVIDE CONDUIT BACK TO SERVER
ROOM FOR CONNECTION TO THE ACCESS CONTROL SYSTEM.
7 PROVIDE LV POWER SUPPLY ABOVE BREAK ROOM AREA FOR THE EXTERIOR CARD READERS. PROVIDE CONDUIT FOR POWER SUPPLY TO EACH DOOR FOR THE LV WIRING. PROVIDE CONDUIT BACK TO
SERVER ROOM FOR CONNECTION TO THE ACCESS CONTROL
SYSTEM.
8 PROVIDE JUNCTION BOX FOR PLUMBING FIXTURES POWER SUPPLY.
COORDINATE EXACT PLACEMENT AND REQUIREMENTS WITH
ARCHITECT & PLUMBING ENGINEER. PRIOR TO ROUGH IN.
9 PROVIDE JUNCTION BOX WITH 1"C.O. FOR SECURITY CAMERAS.
COORIDNATE EXACT PLACEMENT AND HIEGHT WITH ARCHITECT
PRIOR TO ROUGH IN.
10 12"W x 4"H LADDER STYLE CABLE TRAY AT +7'-6" TO BOTTOM OF TRAY.
11 O.F.O.I. RACKS SHOWN FOR REFERENCE.
1/4" = 1'-0"
2 ENLARGED SERVER ROOM
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 312 of 357
CGCG
CG
CG
M
DDD
D
D
DDD
D
MD
MM
M
M
D
M
D
D
D
M
M
D
M
M
D
D
M
DD
D
D
M M
M
D
D
M
M
M
M
M
M
D
M
MM
MM
DS
D
DS
M
DS
M
D
D
D
D D D D D D
2 G
E
J
F
H
3 C
A
98764101
B
5 D
2 G
E
J
F
H
3 C
A
641
B
5 D
LOBBY
100
SERVER
118
OFFICE D1
119
OFFICE D1
120
MULTI-PURPOSE
112
RECEPTION
103
STORAGE
114
RECEIVING
116
OPEN WORK
STATIONS
117
COPY/MAIL
ROOM
115
WOMEN'S
128
OFFICE B
107
HALL
102
RESTROOM
104
CONFERENCE
106
RESTROOM
101
COPY
105
HWH
127
ELECTRICAL
132
MEN'S
129
OFFICE D1
121
MEN'S LOCKER
130
WASH ROOM
131
STORAGE
123
HALL
122
323 SF
FITNESS
126
JAN
124
42 SF
OFFICE D1
111
OFFICE C1
108
OFFICE C1
110
OFFICE C1
109
STORAGE
113
R2R2R2R2ER2R2
R2ER2R2R2R2R2
P1P1P1
P1
P1 P1
P1E
P1
R2
R2
R2
R2
R2
R2
R2E
R2
R2
R2
R3
R3
R3
P1P1P1P1P1P1E
R2 R2
R2R2
P1P1P1P1P1P1
P1 P1E P1
R4E
R2
R2
P1E
R3R3
R3
R1ER1
R4
R1E
R1R1R1R1E
R4
R4
R2R2
R2R2
R4
R4
R4
R4E
R4
R5
R5
R5
R3
P1
P1
P1
P1
P1P1
P1 P1
P1P1
P1EP1
R4R4
R4E R4
R4R4R4
R2
R2
R2
R2
R2R2
R2 R2
P3
P3
P3
P3
P3
P3
P3
P3
P2E
P2P2
R4R4
R2
R2R4R4
R1E R1
R1
R1
R1
R1E R1
R1
R1
R1E
R1
R5
W1
W1
W1
R5
R5
R5
R5R5
R5
R5R5
R5E
P1
FR
133
X1X1
X1
BREAK ROOM
125
X1
W2
W3
a
a a aaaaa
b
b b b b b
b
b b
b b b
aaaaaa
ab
b
bb
ab ab
ab
3ab 3ab
ab
abc
c c
c c
c c
c b
b b
a a
abc
abc
9'-0"AFF +9'-0"AFF
1 2
3 4
R4
R4
R3
R3
R3
9'-0"AFF
9'-0"AFFX1
R4R4
55 10'-4"AFF. TYP.
X1
X1
X1
X1
R4
P2 -2
3/4"C, 1#10, #10N, #10G
2 2
2 2
2 2
2 2
22 2 22
2 6
2 2
P2 -4
4 4
4 4
44 4
44 4 4 4
4 4
4 4
4 4
4 4
4 4
P2 -6
3/4"C, 1#10, #10N, #10G 6
6 6
6 6 6 6
6 66
66 66
66 66
66 66
6 66
P2 -8
1"C, 1#6, #6N, #6G
8 8 8
88888
88 88
8 8 8
8 8 8
8 8
8 8
8 8
8 8
8 8 8
88 P2 -10
1"C, 1#8, #8N, #8G
10 10
10 10
10 10
10 10
1010
1010
10 10
10 10
1010
10 10
10 10
10 14
1010
1010
12 12
12 12 12 12 12
121212121212
12 12 12 12
12 12 12 12
1212
1212
P2 -14
14 14
14 14
14 R4E
2 R4E
222 2
R4R4R4
2 R4
R4E
2 2
3 3
R4R4
22 7
77 7
P1E
a12
P2 -12
1"C, 1#8, #8N, #8G
OFFICE E1
134
OFFICE E1
135
OFFICE E1
136
OFFICE E1
137
OFFICE E1
138
OFFICE E1
139
OFFICE E1
140
X1
X1
R2
R2
R2
R2 R2
R2
R2
R2 R2 R2 R2
R2 R2 R2
P2 -20
20 20
20 20
20 20 20
20 20
20 20
20 20
20 9'-0"AFF
7 8 9 10
X1
X1
4 10
R3
X1
8 X1
5 ab
a
a
a
b
b
abdc
a
bb
c
c
dd
dd
aa
8 8
8 8
S1
8 S1101010
2 R3
10 1010
10 10
R3R3
R3R3
GENERAL NOTES:
A COORDINATE EXACT LOCATION OF LIGHTING FIXTURE WITH
ARCHITECT PLANS PRIOR TO ROUGH IN.
LIGHTING CONTROLS SHALL BE NETWORKABLE LOW VOLTAGE
SYSTEM NLIGHT OR APPORVED EQUAL. PROVIDE
MANUFACTURERS SHOP DRAWINGS FOR ALL LIGHTING CONTROLS
PRIOR TO ROUGH IN. INCLUDING BUT NOT LIMITED TO DEVICE
LOCATIONS, TYPES, CONTROL WIRING, ZONES AND SENSOR
COVERAGE.
VERIFY ALL FINISHES AND MOUNTING WITH ARCHITECT PRI OR TO PROCUREMENT.
B
C
COORDINATE EXACT LOACTION AND QUANITY OF EXTERIOR
LIGHTING FIXTURES WITH ARCHITECT PLANS PRIOR TO ROUGH IN.
D
AN
TON
N A T H A
NSO
N
Exp. 03/31/21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
FIRST FLOOR
PLAN -
LIGHTING
200102
E2.1
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:1/8" = 1'-0"E2.1
1 FIRST FLOOR PLAN - LIGHTING
KEYED NOTES
Key Value Keynote Text
1 ALL EXTERIOR FIXTURES SHALL BE CONTROLLED THRU LIGHTING CONTROL PANEL.
2 HANG FIXTURES AT +10'-0" AFF, KEEP FIXTURES LEVEL ACROSS UNEVEN CEILING.
3 PRIMARY DAYLIGHT ZONE PER TITLE 24.
4 SECONDARY DAYLIGHT ZONE PER TITLE 24.
5 HANG EXIT SIGNS ABOVE DOOR THRESHOLD. COORDINATE EXACT PLACEMENT AND HEIGHT WITH ARCHITECT PRIOR TO ROUGH IN.
6 COORDINATE PLACEMENT OF WALL SIGN FIXTURE WITH ARCHITECT PRIOR TO ROUGH IN.
7 PROVIDE WALL MOUNTED SWTICH FOR INDIVIDUAL FAN ON/OFF OPERATION. COORDINATE LOCATION WITH ARCHITECT PRIOR TO
ROUGH IN.
8 SKYLIGHT ZONE PER TITLE 24.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 313 of 357
DW
CG
CG
CG
CG
CGJ
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
J
2 G
E
J
F
H
3 C
A
641
B
5 D
VAV-2
VAV-1
VAV-3
VAV-4
VAV-5
VAV-10
VAV-11
VAV-6
VAV-14
VAV-7
VAV-13
VAV-8
VAV-9
VAV-12
FC-1
1 P1 -42
VAV-15
VAV-16
VAV-17
7 8 9 10
GENERAL NOTES:
A COORDINATE WITH MECHANICAL DRAWINGS FOR EXACT
PLACEMENT OF DISCONNECTS.
B COORDINATE POWER CONNECTIONS WITH MANUFACTURERS
RECOMMENDATIONS PRIOR ROUGH IN.
C ELECTRICAL CONTRACTOR SHALL COORDINATE WITH
CONTROLS/HVAC CONTRACTOR.
D PROVIDE ENGRAVED NAMEPLATES FOR ALL DISCONNECTS
IDENTIFYING EQUIPMENT SERVED. VERIFY EQUIPMENT NAMES WITH MECHANICAL PLANS PRIOR TO ENGRAVING.
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
FIRST FLOOR
PLAN - MECH
200102
E2.2
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
1/8" = 1'-0"
1 MECH-1ST FLOOR
KEYED NOTES
Key Value Keynote Text
1 FAN COIL IS POWERED FROM CONDENSING UNIT ON ROOF.
COORDINATE EXACT LOCATION AND REQUIREMENTS WITH
MECHANICAL PLANS PRIOR TO ROUGH IN.
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 314 of 357
TTT
T
T
T
T
T
2 G
E
J
F
H
3 C
A
641
B
5 DWPWP
1 1
EF-8EF-7EF-6
EF-5
EF-4
EF-3
EF-2
EF-1
P-1
P-2
CU-1
RTU-1WP
1 WP
1 WP 1
B-1
41 41
41 DB1 -3
3-1/2"C, 3-3/0, 3/0N, #4G
41 P1 -41
3/4"C, 1#8, #8N, #8G
DB1 -4
P2 -22
3/4"C, 1#10, #10N, #10G
22 P2 -24
3/4"C, 1#8, #8N, #8G
24 24
2626P2 -26
1"C, 1#6, #6N, #6G
P2 -28,30
1"C, 2#6, #6N, #6G
P2 -38,40,42
P2 -32,34,36
7 8 9 10
GENERAL NOTES:
A COORDINATE WITH MECHANICAL DRAWINGS FOR EXACT
PLACEMENT OF DISCONNECTS.
B COORDINATE POWER CONNECTIONS WITH MANUFACTURERS
RECOMMENDATIONS PRIOR ROUGH IN.
C ELECTRICAL CONTRACTOR SHALL COORDINATE WITH
CONTROLS/HVAC CONTRACTOR ALL FANS THAT ARE CONTROLLED
VIA ROOM LIGHTING. IF REQUIRED, PROVIDE LOW VOLTAGE RELAY FOR FAN CONTROL VIA LIGHTING SYSTEM.
D PROVIDE ENGRAVED NAMEPLATES FOR ALL DISCONNECTS
IDENTIFYING EQUIPMENT SERVED. VERIFY EQUIPMENT NAMES WITH MECHANICAL PLANS PRIOR TO ENGRAVING.
E ALL EXTERIOR RECEPTACLES SHALL BE GFCI AND PROVIDE IN A WEATHERPROOF IN USE COVER.
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
ELECTRICAL
ROOF PLAN
200102
E3.0
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
KEYED NOTES
Key Value Keynote Text
1 ROOFTOP RECEPTACLES SHALL BE LOCATED WITHIN 25' OF
ROOFTOP UNITS PER CEC.
1/8" = 1'-0"
1 ROOF PLAN POWER
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 315 of 357
TOP OF
CONTROL
TOP OF CONTROL SWITCH
OUTLET
SIDE APPROACH
44" MAX FOR
FRONT APPROACH
NOTE:
MOUNTING HEIGHT DIMENSIONS
ARE TYPICAL FOR ALL HAND
OPERABLE DEVICES.
FINISHED
FLOOR
FINISHED
GRADE
OUTLET
48"
MAX.
15"
MIN.
46"
MAX.
34"
MAX.
24"
MAX.
BONDING & GROUND DETAIL
CONCRETE ENCASED ELECTRODE (UFER) (GROUNDING
ELECTRODE #1). REFER TO CHART FOR SIZE. MINIMUM 20'.
A
MINIMUM 10 MIL ANNEALED COPPER CLAD STEEL GROUND
ROD. (GROUNDING ELECTRODE #2). REFER TO CHART FOR
SIZE.
B
GROUNDING ELECTRODE CONDUCTOR. REFER TO CHART
FOR SIZE.
C
INTEGRATED (FACTORY BONDED) BUS BAR MAIN BONDING
JUMPER. REFER TO CHART FOR MINIMUM CONDUCTOR
SIZE. (AMPACITY SHALL BE 150% RATED)
D
METALLIC PIPING BOND WIRE, REFER TO CHART FOR
MINIMUM SIZE. BOND TO ALL METALLIC PIPING (WATER,
SPRINKLER, GAS, PNEUMATIC LINES, ETC.) WITHIN THE
FIRST ACCESSIBLE 5' OF PIPES ENTRY INTO BUILDING.
E
BUILDING STEEL BOND WIRE (IF REQUIRED PER BUILDING
CONSTRUCTION TYPE). REFER TO CHART FOR MINIMUM
SIZE.
F
BOND WIRE FOR USE WITH MULTIPLE SERVICE's (WHEN
PRESENT). REFER TO CHART FOR MINIMUM SIZE.
G
INTEGRATED (FACTORY BONDED) BUS BAR CASE BOND.
REFER TO CHART FOR MINIMUM CONDUCTOR SIZE.
H
INTEGRATED (FACTORY INSTALLED) GROUND BUS BAR.
SHALL BE SIZED TO ACCOMMODATE GROUND WIRE LUGS
AS INDICATED ON THE ONE-LINE DIAGRAM.
J
SES AMPACITY B D E F&G H
200 AMP 3/4"x10' (x1)#2 #2 #2 #2
400 AMP 3/4"x10' (x1)#1/0 #1/0 # 1/0 #1/0
600 AMP 3/4"x10' (x1)#3/0 #3/0 # 3/0 #3/0
800 AMP 3/4"x10' (x2)#3/0 #3/0 # 3/0 #3/0
1000 AMP 3/4"x10' (x2)#4/0 #3/0 # 3/0 #4/0
1200 AMP 3/4"x10' (x2)#4/0 #3/0 # 3/0 #4/0
1600 AMP 3/4"x10' (x2)#300 #3/0 # 3/0 #300
2000 AMP 3/4"x10' (x3)#350 #3/0 # 3/0 #350
2500 AMP 3/4"x10' (x3)#500 #3/0 # 3/0 #500
3000 AMP 3/4"x10' (x3)#500 #3/0 # 3/0 #500
3600 AMP 3/4"x10' (x3)#700 #3/0 # 3/0 #700
A&C
4 4
4 4
4 4
4 4
4 4
4 ALL SIZES SHOWN ARE FOR Cu.. AL. IS NOT PERMITTED.
20'
A
B
C
D
F
G
E
H
J
N
G
LIGHT FIXTURE OR SPEAKER ENCLOSURE
NOTES:
4 6
5 3
2 1
1 4
2 6
5 3
4 3
2 5
45 3
21 1
6 6
NOTES:
TROFFER LIGHTING SEISMIC RESTRAINT DETAIL
DOWN LIGHTING SEISMIC RESTRAINT DETAIL LOW BAY SEISMIC RESTRAINT DETAIL
UNOBSTRUCTED CIRCUMFERENCE
45°
HANGING LINEAR FIXTURE
BRACE WIRE
OR CABLE
SWIVEL JOINT
HANGER
9 SAFETY WIRE TIED TO SAFETY WIRE SUPPORT
HOLE & FASTENED TO BLDG. STRUCTURE W/ |''x 2\''
LONG SCREW-EYE OR EQUAL.
ATTACH TO SUSPENSION SYSTEM W/CLIPS OR
WIRE TIES.
EXPOSED T-BAR CEILING SYSTEM OR CONCEALED
SUSPENSION SYSTEM
SAFETY WIRE SUPPORT HOLE IN FIXTURE OR
SPEAKER ENCLOSURE
MOUNTING CHANNELS OR T-BAR BRIDGE TO SPAN
CEILING SUSPENSION SYSTEM AS
RECOMMENDED BY MFR.
SEISMIC RESTRAINT CLIP MINIMUM (2) TWO PER
LIGHT FIXTURE, SCREWED TO T-BAR PER
SPECIFICATIONS. TYPICAL.
12 GA. SLACK SAFETY WIRE TIED TO SEISMIC CLIPS
OR SAFETY WIRE SUPPORT HOLES AND ANCHOR TO
BLDG. STRUCTURE. MINIMUM (2) SAFETY WIRES
PER EACH LIGHT FIXTURE 1'x4, 2'x2' OR SMALLER.
MINIMUM (4) SAFETY WIRES PER LIGHT FIXTURE
FOR 2'x4' OR LARGER FIXTURES.
FASTEN SEISMIC RESTRAINT CLIPS TO LIGHT
FIXTURE WITH HEX WASHER HEAD. SHEET METAL
SCREWS, MINIMUM (2) TWO PER CLIP (OPTIONAL
METHOD). USE IF SAFETY WIRE SUPPORT HOLES
ARE NOT PROVIDED WITH FIXTURE.
LIGHT FIXTURE SAFETY WIRE SUPPORT HOLE TYPICAL.
EXPOSED T-BAR CEILING SYSTEM, HEAVY DUTY GRID
TYPICAL.
5/16'' DIA. DRILL-IN EXPANSION ANCHOR (TO CONCRETE)
OR (2) #8 x 1/2'' SELF-TAPPING SCREWS (TO METAL
DECKING).
ANCHOR TO
STRUCTURE
TYPICAL)
CABLE DESCRIPTION
CIRCUIT'S ACTUAL VOLTAGE RATING.
CIRCUIT'S ACTUAL DESIGNATION.
SUBMIT COMPLETE AND PROPER
SCHEDULE OF THE CIRCUIT
DESIGNATIONS TO BE USED. PROVIDE
DESCRIPTIONS FOR EACH MANHOLE
INVOLVED.
CABLE'S ACTUAL PHASE DESIGNATION.
CABLE'S ACTUAL SIZE DESIGNATION.
1" HIGH POLYETHYLENE "BLANK" INSERT
TILE WITH YELLOW FINISH
1" HIGH POLYETHYLENE INSERT TILE WITH BLACK ON
YELLOW FINISH AND STANDARD BLOCK CHARACTERS.
TYPICAL CABLE IDENTIFICATION SHOWN.
PRIMARY CABLE WITH FIREPROOFING TAPE
POLYETHYLENE TAG HOLDER WITH BLACK FINISH
SELF-LOCKING NYLON TIE STRAP
KV
13.2 C TK Y
B
4 0
1. 2.
3. 4.
32 4
1 3''
12''
3''
3''3''
3''
BACKFILL COMPACT
TO 95% RELATIVE
DENSITY
SHOWN ON PLANS
CONDUIT(S) AS
WARNING TAPE
OR PAVING
MIN.
24''
FINISHED GRADE
3'' CONCRETE ENCASEMENT AT
PARKING LOT AND DRIVEWAYS
FOR ALL CONDUIT 2'' AND
LARGER. 3'' SAND ENCASEMENT
AT LANDSCAPED AREAS
EXACT DEPTH TO BE
DETERMINED IN FIELD
BY COORDINATION
WITH EXISTING
UTILITIES.
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
ELECTRICAL
DETAILS
200102
E4.1
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
12" = 1'-0"
1 ADA DETAIL
12" = 1'-0"
2 GROUNDING DETAIL
12" = 1'-0"
3 SIESMIC DETAIL
12" = 1'-0"
4 CABLE TAG DETAIL
12" = 1'-0"
5 TRENCH DETAIL
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 316 of 357
M
M DS
M DS
M
M
M DS
M
DS
1 2
2 34
1 2
3 4
5 6
1. REFER TO LIGHTING AND
POWER PLANS FOR QUANTITY
AND APPROXIMATE LOCATION
OF LIGHTING FIXTURES,
RECEPTACLES, DEVICES AND
CONTROLS.
2. WIRING CLASS AND TYPE CAN
VARY PER MANUFACTURER
AND CONTROL SYSTEM.
VERIFY ALL WIRING AND
CONTROLS WITH
MANUFACTURER PRIOR TO
INSTALLATION.
3. AUTOMATIC DAYLIGHTING
CONTROLS SHALL BE
INSTALLED ONLY IF THE TOTAL
COMBINED WATTAGE
INSTALLED IS GREATER THAN
120 WATTS AND IN ROOMS
THAT HAVE MORE THAN 24sq ft
OF GLAZING.
GENERAL NOTES
6 6
6 6
CEC REQUIREMENT NOTES
c
a
b
a
b
4 5
b b
6 6
6 6
c
4 5
a a
6 6
1 2
3 1
2 2
2 3
1. REFER TO LIGHTING AND
POWER PLANS FOR QUANTITY
AND APPROXIMATE LOCATION
OF LIGHTING FIXTURES,
RECEPTACLES, DEVICES AND
CONTROLS.
2. WIRING CLASS AND TYPE CAN
VARY PER MANUFACTURER
AND CONTROL SYSTEM.
VERIFY ALL WIRING AND
CONTROLS WITH
MANUFACTURER PRIOR TO
INSTALLATION.
3. AUTOMATIC DAYLIGHTING
CONTROLS SHALL BE
INSTALLED ONLY IF THE TOTAL
COMBINED WATTAGE
INSTALLED IS GREATER THAN
120 WATTS AND IN ROOMS
THAT HAVE MORE THAN 24sq ft
OF GLAZING.
GENERAL NOTES
6 6
6 6
4 4
5 6
CEC REQUIREMENT NOTES
6 4
5 4 5
6 6
6 6
6 4
6 6
OCCUPANCY SENSOR
per section 130.1(C)
PLUG LOAD CONTROL
per section 130.5 (D)
DAYLIGHT
HARVESTING
per section 130.1(D)
SWITCH WITH ON/OFF
RAISE/LOWER
per section 130.1(A)
RELAY MODULE WITH ON/OFF
DIMMING
per section 130.1(B)
AUTOMATIC DEMAND
RESPONSE
per section 130.1(E)
Dab
N
SECONDARY DAYLIGHTNIG ZONE
277/120VAC DIMMING
GRN
BLUE
W
H
T
B
L
K
O
R
N
BL
U
E
N H
CONTINUE
AS REQ'D
SEE PLANS
N
PRIMARY DAYLIGHTNIG ZONE
277/120VAC DIMMING
GRN
BLUE
CONTINUE
AS REQ'D
SEE PLANS
BLUE
W
H
T
BL
K
BL
U
E
N H
CONTINUE
AS REQ'D
SEE PLANS
W
H
T
B
L
K
O
R
N
BL
U
E
N H
NOTE DESCRIPTION
16 AMP RELAY PACK WITH DIMMING CONTROL
16 AMP RELAY PACK FOR PLUG LOAD CONTROL
ON/OFF SWITCH WITH DIMMING
NOTE DESCRIPTION
STANDARD RANGE 360° SENSOR-CEILING MOUNT
AUTOMATIC DIMMING CONTROL PHOTOCELL- CEILING MOUNT
CONTROL WIRE - CAT5/6, 0-10V, OR LINE VOLTAGE
PER MANUFACTURER REQUIREMENTS)
BLK - 120VAC OR ORN - 277VAC
SCHEMATIC OF TYPICAL CEILING-MOUNTED MOTION & DAYLIGHT - WIRING DIAGRAM PLUG
LIGHTING
LIGHTING
GRN
BILL OF MATERIAL
N
c
CONTINUE AS REQ'D
SEE PLANS
SCHEMATIC OF TYPICAL CEILING-MOUNT WITH MANUAL DIMMING - WIRING DIAGRAM
BILL OF MATERIAL
NOTE DESCRIPTION
16 AMP RELAY PACK WITH DIMMING CONTROL
16 AMP RELAY PACK FOR PLUG LOAD CONTROL
ON/OFF SWITCH WITH DIMMING
Dabc
N
SECONDARY DAYLIGHTNIG ZONE
277/120VAC DIMMING
GRN
BLUE
W
H
T
B
L
K
O
R
N
BL
U
E
N H
CONTINUE AS
REQ'D
SEE PLANS
N
PRIMARY DAYLIGHTNIG ZONE
277/120VAC DIMMING
GRN
BLUE
CONTINUE
AS REQ'D
SEE
PLANS
W
H
T
B
L
K
O
R
N
BL
U
E
N H
BLUE
W
H
T
BL
K
BL
U
E
N H
CONTINUE
AS REQ'D
SEE PLANS
NMANUAL
277/120VAC DIMMING
GRN
BLUE
CONTINUE
AS REQ'D
SEE PLANS
W
H
T
B
L
K
O
R
N
BL
U
E
N H
BLK - 120VAC OR ORN - 277VAC
NOTE DESCRIPTION
STANDARD RANGE 360° SENSOR-CEILING MOUNT
AUTOMATIC DIMMING CONTROL PHOTOCELL- CEILING MOUNT
CONTROL WIRE - CAT5/6, 0-10V, OR LINE VOLTAGE
PER MANUFACTURER RECOMMENDATION)
N
c
b
a
OCCUPANCY SENSOR
per section 130.1(C)
PLUG LOAD CONTROL
per section 130.5 (D)
DAYLIGHT
HARVESTING
per section 130.1(D)
SWITCH WITH ON/OFF
RAISE/LOWER
per section 130.1(A)
RELAY MODULE WITH ON/OFF
DIMMING
per section 130.1(B)
AUTOMATIC DEMAND
RESPONSE
per section 130.1(E)
GRN
c
b
a
PLUG
LIGHTING
a a
b
b
d
c
d
d
LIGHTING
LIGHTING
CONTINUE
AS REQ'D
SEE PLANS
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
ELECTRICAL
DETAILS
200102
E4.2
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
SCALE:12" = 1'-0"E4.2
1 CONTROL DIAGRAMS
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 317 of 357
FIRST LEVEL CORR.
MSB-3150A. 3P.
ELECTRICAL SERVICE
ALL LETTERS ARE CAPITAL
LINE 2 - EQUIPMENT BEING SERVED
LINE 1 -DISCONNECT NAME
LINE 3 - SIZE OF FEEDER / FEEDER
NO.
BLACK ON WHITE
LAMINATED PLASTIC 3/32''
THICK MIN. WITH BEVELED
EDGE
CADMIUM OR STAINLESS
STL. ROUNDHEAD SCREWS
DISCONNECT
FIRST LEVEL CORR.
MSB-3150A. 3P.
PANEL A
ALL LETTERS ARE CAPITAL
LINE 2 -LOCATION OF EQUIPMENT
BEING SERVED (SW. BD. NP'S ONLY)
LINE 1 -EQUIPMENT NAME
LINE 3 - SIZE OF FEEDER / FEEDER
NO.
BLACK ON WHITE
LAMINATED PLASTIC 3/32''
THICK MIN. WITH BEVELED
EDGE
CADMIUM OR STAINLESS
STL. ROUNDHEAD SCREWS
PANELS
DISCONNECTING
MEANS _ OF _
3"1" Min.
3"1" Min.
PER PLAN
RATED FIREWALL
APPROVED U.L. LISTED FIRESTOP
MATERIAL, INSTALLED IN
CONFORMANCE WITH
MANUFACTURER'S INSTRUCTIONS
MAX 1-1/2" DIAMETER
STEEL CONDUIT
F RATING = 1 OR 2 HOUR
T RATING = 1 HOUR
PER PLAN
RATED FIREWALL
APPROVED U.L. LISTED FIRESTOP
MATERIAL, INSTALLED IN
CONFORMANCE WITH
MANUFACTURER'S INSTRUCTIONS
MAX 2" DIAMETER
STEEL CONDUIT
F RATING = 1 OR 2 HOUR
T RATING = 1 HOUR
FIRE STOPPING DETAIL FOR 2" CONDUIT
FIRE STOPPING DETAIL FOR 1" AND SMALLER CONDUIT
TO BE CONSISTENT WITH U.L. PENETRATION
FIRESTOP SYSTEM No. W-L-1050 FOR WALL
ASSEMBLY - PER ARCHITECTURAL PLANS
TO BE CONSISTENT WITH U.L. PENETRATION
FIRESTOP SYSTEM No. W-L-1012 FOR WALL
ASSEMBLY - PER ARCHITECTURAL PLANS
BUR MEMBRANE
ROOFING
CONDUIT, SEE DRAWINGS
FOR LOCATION & SIZE
SEALANT
24 G.A. 24 G.I. FLASHING SET
ON MASTIC OVER ROOFING.
STRIP IN WITH BASE
FLASHING
ROOF
4" MIN.
2" 2"
12"
PLYWOOD ROOF
1 THREADED HUB.
GALVANIZED PIPE STRAP, TYP.
RGS CONDUIT.
BUILDINGS WALL.
TRANSITION COUPLING.
FINISH GRADE.
WHERE NECESSARY.
WEATHERPROOF BOX. JUNCTION
BOX SIZED PER NEC.
PAINT CONDUITS AND JUNCTION BOX
TO MATCH EXISTING WALL SURFACE.
9 2
3 4
5 6
7 8
NOTES:
1 8
2 4
3 TYP.
5 76
MOUNT DISCONNECT DIRECTLY
TO UNIT AT POINT OF
CONNECTION PROVIDED
FOR DISCONNECT SIZE REFER
TO ELECTRICAL ROOF PLAN.
CONDUIT TO
POWER SOURCE
ROOFTOP UNIT AS
NOTED ON ROOF
PLANS
HVAC UNIT
SERVICE
PANEL
ROOF
LIGHTING CONTROL DIAGRAM NOTES:
LIGHTING CONTROL PANEL 'LCP' PANEL SCHEDULE
LIGHTING CIRCUIT
P2''
PANEL
LVHV
P1-16
RM #111
WALL
MOUNTED
PHOTOCELL
ROOF
MOUNTED
NORTH FACING
PHOTOCELL
EXTERIOR LIGHTING CIRCUIT WITH PHOTOCELL ''ON'' TIME CLOCK 12 LIGHTING BRANCH CIRCUIT PANEL ''P2''.
LIGHTING CONTROL PANEL ''LCP''.1
2 1
OFF' CONTROL.
NO.
P-2
NO.
RELAY
2 3
1 CIRCUIT
PANEL
5 4
6 LIGHTING AREASERVEDNO.
ZONE
2 3
1 5
4 NOTES
TYPE &
1 1
CONTROL
1 1
5 6
2 PROVIDE PANEL WITH U.L. LISTED AND APPROVEDVOLTAGE5
BARRIER.
CONTACT INPUTPHOTOCELL3
EXTERIOR CONTACT INPUTPHOTOCELL4
3 1
1 4
INTERIOR TIME CLOCK ''ON'', TIME CLOCK ''OFF'' CONTROL. 3 EXTERIOR FACADE LIGHTING
J
CR
12"
48"
FLOOR, REF.
LINE OF
AND FRAME, REF.
SINGLE DOOR
AND BLOCK LAYOUT
STRUCTURAL STEEL
WITH THE
COORDINATE
ASREQUIRED4SRECESSEDBOX
AND BLANK COVER
WITH 1/2" KNOCK
OUT FOR CARD
READER
MORTISE LOCK
WITH HANDLE
L-LOCK) DOOR
TO BE DRILLED
BY OTHERS
POWER
TRANSFER
HINGE
SECURITY DOOR
CONTACT DEVICES
BY OTHERS)
DOOR CONTACT 3" FROM
LATCH SIDE OF DOOR
UNLESS THE DOOR IS
METAL, THEN 6" FROM
LATCH SIDE OF DOOR EDGE
NOTE:
CARD READERS SHALL HAVE
MANUAL OVERRIDE FOR
EXITING IN CASE OF POWER
OUTAGE.
CEILING LINE
4x4 J-BOX, MOUNT ON
SECURE SIDE
3/4" IN EMT
NOTE:
VERIFY ALL REQUIREMENTS WITH
SECURITY SHOP DRAWINGS.
3/4" IN EMT
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
ELECTRICAL
DETAILS
200102
E4.3
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
12" = 1'-0"
1 NAMEPLATE DETAIL
12" = 1'-0"
2 PENETRATION DETAILS
12" = 1'-0"
3 ROOF PENETRATION DETAIL
12" = 1'-0"
4 ROOF RECEPTACLE DETAIL
12" = 1'-0"
5 DISCONNECT MOUNTING DETAIL
12" = 1'-0"
6 LIGHTING CONTROL PANEL
12" = 1'-0"
7 CARD READER DETAIL
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 318 of 357
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
TITLE 24
200102
E5.1
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 319 of 357
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
TITLE 24
200102
E5.2
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 320 of 357
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
TITLE 24
200102
E5.3
AN
AN
KS
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 321 of 357
CONDUIT STUBOUT
CONDUIT RISING UP
CONDUIT DROP DOWN
8 CONDUIT CONCEALED IN WALLS OR CEILING.
FLEXIBLE CONDUIT
HOMERUN TO PANEL AND CIRCUITS INDICATED.
CROSSMARKS DENOTE QUANTITY OF NEUTRAL
LONG), PHASE (SHORT), AND GROUND (DOT)
CONDUCTORS IN BRANCH CIRCUIT CONDUIT. NO
CROSSMARKS DENOTES PHASE, NEUTRAL, AND
GROUND WIRES. NUMBER ADJACENT TO CROSSMARKS
DENOTES WIRE SIZE OTHER THAN #12 FOR ALL
CONDUCTORS UNO.
DETAIL NUMBER DESIGNATION
SHEET ON WHICH DETAIL IS FOUND
E1
3 SHEET NOTE REFERENCE
GENERAL SYMBOLS LEGEND
A-1
1 CONDUIT CONCEALED IN FLOOR, UNDERFLOOR,
OR BELOW GRADE
ELECTRICAL ABBREVIATIONS
PULL BOX
PHASE
POLE
NOT TO SCALE
PH.
P
PB
NTS
ATS
C
AFF
ALT.
A
AUTOMATIC TRANSFER SWITCH
ABOVE FINISHED FLOOR
CONDUIT
AMPERES
ALTERNATE
PANEL
RECEPTACLE
REQUIRED
RIGID GALVANIZED STEEL
POST INDICATOR VALVE
POINT OF CONNECTION
SECURITY
SWITCHGEAR
TYPICAL
TERMINAL CABINET
UNDER COUNTER
TELEPHONE
UNLESS NOTED OTHERWISE
WATTS
VOLTS
TRANSFORMER
NEW LOCATION OF EXISTING ITEM
WEATHERPROOF
WATER HEATER
PNL
PIV
RECEPT
RGS
SEC
UNO
TYP
U.C.
TEL.
TC
CONC.
CB
C.O.
CKT.
DWG.
DIST.
GFI
FA
HORIZ.
JB
LTG.
MCA
GROUND FAULT INTERRUPTER
HORIZONTALLY MOUNTED
LIGHTING
JUNCTION BOX
CONDUIT ONLY
EMERGENCY SERVICE
FIRE ALARM
CONCRETE
DRAWING
DISTRIBUTION
CIRCUIT BREAKER
CIRCUIT
MINIMUM CIRCUIT AMPS W
WP
V
W.H.
XL
MTD.
MCC
MOP
MTG. HT.
NL
NIC
NIGHT LIGHT
NOT IN CONTRACT
MOTOR CONTROL CENTER
MOUNTED
MOUNTING HEIGHT
MAXIMUM OVERCURRENT PROTECTION
XFMR
SWGR.
REQ'D
POC
OWNER FURNISHED, CONTRACTORINSTALLEDOFCI
CFCI CONTRACTOR FURNISHED, CONTRACTOR INSTALLED
FLA FULL LOAD AMPS
SOLIDNEUTRALS.N.
EXISTING TO BERELOCATEDXR
EXISTING TOREMAINX
EXISTING TO BEDEMOLISHEDXD
CU COPPER
EG EQUIPMENT GROUND
TAMPERRESISTANTTR
EXIST. EXISTING
EM
ONCENTEROC
MEP MECHANICAL, ELECTRICAL, PLUMBING
TENANTIMPROVEMENTT.I.
UNDERWRITERSLABORATORYUL
CFL COMPACT FLUORESCENT LAMP
REFLECTED CEILINGPLANRCP
ADA AMERICANS WITH DISABILITIES ACT
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
KVA KILOVOLT-AMPERES
KW KILOWATTS
HP HORSEPOWER
L LOCKABLE
EX EXISTING
NON-FUSIBLE DISCONNECT SWITCH
RATINGS AS NOTED)
FUSIBLE DISCONNECT SWITCH
RATINGS AS NOTED)
M
T
J
CIRCUIT BREAKER CALLOUT
FUSE CALLOUT
POLE
TRIP SIZE
FUSE SIZE
POLE
NON-FUSIBLE DISCONNECT SWITCH (RATINGS AS NOTED)
FUSIBLE DISCONNECT SWITCH (RATINGS AS NOTED)
COMBINATION FUSIBLE DISCONNECT SWITCH AND MOTOR
STARTER, (NEMA SIZE AS NOTED), 3P, 600 VAC MAXIMUM
RATING.
T TOGGLE TYPE FRACTIONAL HP MANUAL MOTOR STARTER
WITH THERMAL OVERLOADS (DELETED IF FOR
DISCONNECT USE ONLY) AND HANDLE GUARD/LOCK-OFF,
2 POLES (VERIFY WITH BRANCH CIRCUIT).
MOTOR
GROUND
CIRCUIT BREAKER
TRANSFORMER DELTA PRIMARY, WYE
SECONDARY WITH kVA RATING
GFP
SPD SURGE PROTECTION DEVICE
GROUND FAULT PROTECTION
ENCLOSED CIRCUIT BREAKER
SINGLE LINE LEGEND
TC TIME CLOCK
KILOWATT-HOUR METER
FUSED SWITCH
MOTOR STARTER (NEMA SIZE AS NOTED)
CB
AUTOMATIC TRANSFER
SWITCH
PANEL BOARD
2 2
3 225
150
3 EPO - EMERGENCY POWER OFF BUTTON
PANEL BOARD (SURFACE)
SWITCHBOARD OR MCC
POWER LEGEND
PANEL BOARD (FLUSH)
TRANSFORMER
JUNCTION BOX
LCP
LOW VOLTAGE PANEL
LIGHTING CONTROL PANEL
TELEPHONE BACKBOARD. 3/4'' PLYWOOD, LENGTH AND
WIDTH AS NOTED.
EQUIPMENT SIZES SHOWN ON PLANS ARE NOT EXACT. CONTRACTOR IS
RESPONSIBLE FOR ENSURING EQUIPMENT CLEARANCES ARE MET BASED ON ACTUAL SIZE OF EQUIPMENT.
PHOTOVOLTAIC LEGEND
G N
INVERTER
G
G
PV MODULE
PV ARRAY: S#.#-#
MPPT
STRING NUMBER
ASSOCIATED INVERTER
TOTAL SYSTEM WATTAGE
MODULE DC NAMEPLATE
INVERTER AC NAMEPLATE
ANNUAL PRODUCTION
88.8 KW
168 KW
133 MWh
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
ELECTRICAL PV
SYMBOLS
200102
PV0.1
AN
AN
MG
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 322 of 357
ALUMINUM CONDUCTOR INSTALLATION NOTES
1. MINIMUM WIRE SIZE FOR POWER LINES WHEN IMPLEMENTING ALUMINUM AS A CONDUCTOR SHALL BE #4 AWG STRANDED, COMPACT ELECTRICAL GRADE AA-8000 SERIES ALLOY.
2. ALUMINUM POWER CABLE, WIRE CONNECTORS, AND INSULATING AND CODING TAPE MANUFACTURERS SHALL BE APPROVED BY CLIMATEC PRIOR TO USAGE.
3. WHERE BOLTED CONNECTIONS ARE NOT POSSIBLE, MECHANICAL SCREW STYLE
LUGS AND TERMINATIONS ARE APPROVED ONLY WHEN USED IN CONJUNCTION WITH A LISTED COPPER PIGTAIL COMPRESSION ADAPTOR. USE OF A ONE-SHOT" CRIMPER OR "DIE-LESS CRIMPERS" WILLNOT BE ALLOWED
4. COMPRESSION STYLE LUGS AND TERMINATIONS SHALL BE RATED FOR THE MAXIMUM DC VOLTAGE OF THE SYSTEM.
4.1. MUST BE PRE-FILLED WITH OXIDE INHIBITOR.
4.2. WIRE STRIPPING AND BRUSHING OF CONDUCTOR IN ACCORDANCE WITH VENDOR SPECS IS REQUIRED IMMEDIATELY PRIOR TO LUG INSTALLATION.
4.3. OXIDE INHIBITOR MUST BE APPLIED TO EXPOSED CONDUCTOR IMMEDIATELY
AFTER STRIPPING AND BRUSHING AND IMMEDIATELY PRIOR TO INSTALLATION OF THE LUG.
4.4. USE COMPRESSION TOOL LISTED FOR USE WITH SELECTED COMPRESSION CONNECTOR.
4.5. COLD SHRINK SHALL BE APPLIED TO COVER ANY EXPOSED WIRE SURFACE AT THE JUNCTION WHERE THE WIRE MEETS THE TERMINAL.
4.6. ALL CONNECTORS AND CORRESPONDING CRIMPING TOOLS SHALL BE UL LISTED FOR THEIR SPECIFIC APPLICATION.
5. INSULATING AND COLOR CODING TAPE SHALL BE PREMIUM GRADE PRESSURE SENSITIVE VINYL, HEAT/COLD/MOISTURE/SUNLIGHT/ RESISTANT. INSULATING TAPE SHALL BE BLACK AND COLOR CODING TAPE SHALL BE FADE RESISTANT.
6. FOR ALUMINUM MV CONDUCTORS, WHERE USED, THE GUIDELINES IN THIS
SECTION PLUS GENERAL REQUIREMENTS FOR MV CONDUCTOR INSTALLATION SHALL APPLY.
GROUNDING
SEE ELECTRICAL DIAGRAM AND ELECTRICAL DETAILS FOR MORE GROUNDING INFORMATION.
1. ONLY ONE CONNECTION TO DC CIRCUITS AND ONE CONNECTION TO AC CIRCUITS WILL BE USED FOR SYSTEM GROUNDING (CEC 250-21) (REFERENCED TO THE SAME POINT).
2. EQUIPMENT GROUNDING CONDUCTORS AND SYSTEM GROUNDING
CONDUCTORS WILL HAVE AS SHORT A DISTANCE TO GROUND AS POSSIBLE AND A MINIMUM NUMBER OF TURNS.
3. NON-CURRENT CARRYING METAL PARTS SHALL BE CHECKED FOR PROPER GROUNDING; NOTING THAT TERMINAL LUGS BOLTED ON AN ENCLOSURE'S FINISHED SURFACE MAY BE INSULATED BECAUSE OF PAINT/FINISH.
PAINT/FINISH AT POINT OF CONTACT SHALL BE PROPERLY REMOVED.
4. RACKING COMPONENTS AND STRUCTURAL SUPPORTS MUST BE ELECTRICALLY BONDED TOGETHER BY AN ACCEPTABLE MEANS.
5. MODULES SHALL BE GROUNDED WITH EQUIPMENT GROUNDING CONDUCTORS
BONDED TO A LOCATION APPROVED BY THE MANUFACTURER WITH A MEANS OF BONDING LISTED FOR THIS PURPOSE.
6. THE CONNECTION TO THE MODULE OR PANEL OF THIS PROPOSED SOLAR
ELECTRIC SYSTEM SHALL BE SO ARRANGED THAT REMOVAL OF A MODULE OR
A PANEL FROM THE PHOTOVOLTAIC SOURCE CIRCUIT DOES NOT INTERRUPT A GROUNDED CONDUCTOR TO ANOTHER PHOTOVOLTAIC SOURCE CIRCUIT.
SETS OF MODULES INTERCONNECTED AS SYSTEMS RATED AT 50 VOLTS OR
LESS WITH OR WITHOUT BLOCKING DIODES, AND HAVING A SINGLE OVER CURRENT DEVICE SHALL BE CONSIDERED AS A SINGLE SOURCE CIRCUIT.
7. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,
INCLUDING BUT NOT LIMITED TO GROUND RODS, GROUNDING LUGS, GROUNDING CLAMPS, ECT.
8. ALL GROUNDING CONNECTIONS SHALL BE RATED FOR DIRECT BURIAL (DB
RATED) , CONTRACTOR IS TO SUPPLY DOCUMENTATION PROVING THIS
DURRING PRODUCT SUBMITTALS
ELECTRICAL NOTES FOR NEW PHOTOVOLTAIC SYSTEM:
1. THIS PROPOSED SOLAR ELECTRIC SYSTEM IS INTENDED TO OPERATE IN PARALLEL WITH POWER RECEIVED FROM THE UTILITY SERVICE PROVIDER.
2. THE INVERTER FOR THE PROPOSED SOLAR ELECTRIC SYSTEM SHALL BE IDENTIFIED FOR USE IN SOLAR PHOTOVOLTAIC SYSTEMS. ALL EQUIPMENT SHALL BE UL APPROVED.
3. THIS SYSTEM IS INTENDED TO CONNECT TO THE EXISTING FACILITY POWER SYSTEM AT ONE POINT, POINT OF COMMON COUPLING (POCC). THIS CONNECTION SHALL BE IN COMPLIANCE WITH THE CEC ARTICLE 705.12 "POINT OF CONNECTION".
4. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION FOR TESTING AND ISOLATION.
5. ALL DISCONNECTING COMBINERS SHALL BE SECURED FROM
UNAUTHORIZED/UNQUALIFIED PERSONNEL BY LOCK OR LOCATION.
6. ALL DISCONNECTING COMBINERS, PULL/SPLICE BOXES, AND ENCLOSURES SHALL BE LISTED FOR IT'S PURPOSE.
7. EQUIPMENT SHALL BE INSTALLED IN A SECURE AREA. INVERTER PERFORMANCE MAY BE AFFECTED IF INSTALLED IN DIRECT SUNLIGHT.
WIRING AND WIRING METHODS
ALL WIRING METHODS AND INSTALLATION PRACTICES SHALL CONFORM TO THE
NATIONAL ELECTRIC CODE, LOCAL STATE CODES, AND OTHER APPLICABLE LOCAL CODES
1. EXPOSED PV SOLAR PANEL WIRING WILL BE PV WIRE OR APPROVED EQUIVALENT, 90 DEGREE C, WET RATED AND UV RESISTANT. ALL EXPOSED
CABLES, SUCH AS MODULE LEADS SHALL BE SECURED WITH MECHANICAL OR OTHER SUN-LIGHT RESISTANT MEANS.
2. PV STRING HOME RUNS SHALL BE LABELED ON BOTH ENDS, AT ARRAY AND AT COMBINER. COMBINER OUTPUT CONDUCTORS SHALL BE LABELED AT BOTH ENDS, AT COMBINER AND AT DISCONNECT.
3. LIQUID TIGHT FLEXIBLE METAL CONDUIT IS GENERALLY SUITABLE FOR INSTALLATION IN WET AND DRY LOCATIONS. SHOULD IT BE EMPLOYED, SUPPORTS WILL BE NO MORE 12 INCHES FROM BOXES (JUNCTION BOX, CABINETS, OR CONDUIT FITTING) AND NO MORE THAN 36 INCHES APART (CEC 350.30)
4. THE PHOTOVOLTAIC SOURCE CIRCUITS AND PHOTOVOLTAIC OUTPUT CIRCUITS
OF THIS PROPOSED SOLAR SYSTEM SHALL NOT BE CONTAINED IN THE SAME
RACEWAY CABLE TRAY, CABLE, OUTLET BOX, JUNCTION BOX, OR SIMILAR
FITTING AS FEEDERS OR BRANCH CIRCUITS OF OTHER SYSTEMS UNLESS THE
CONDUCTORS OF THE DIFFERENT SYSTEMS ARE SEPARATED BY A PARTITION OR ARE CONNECTED TOGETHER.
5. UNLESS MARKED AS UV RESISTANT, PVC IS NOT APPROVED FOR INSTALLATION IN
LOCATIONS SUBJECTED TO DIRECT SUNLIGHT AND SHALL NOT BE EMPLOYED IN ANY SUCH LOCATION.
6. LONG STRAIGHT EXPOSED CONDUIT RUNS, 100 FEET OR MORE, SHALL HAVE EXPANSION FITTINGS INSTALLED PER CEC 300.7(B). EXPANSION FITTINGS SHALL ALSO BE USED WHEN CONDUIT SPANS AN EXPANSION JOINT.
7. FUSES AND WIRES SUBJECT TO TRANSFORMER INRUSH CURRENT SHALL BE SIZED ACCORDINGLY.
8. ALL D.C. MATERIALS SHALL BE UL LISTED FOR MAXIMUM DC SYSTEM VOLTAGE.
9. WHEN TRANSITIONING UNDERGROUND PVC CONDUIT TO ABOVE GROUND RMC, IMC OR EMT CONDUIT, USE 20 MIL PIPE WRAP TAPE HALF-LAPPED FROM 6” PAST TRANSITION POINT ON PVC TO 6” ABOVE GROUND ON METALLIC CONDUIT. AN EXPANSION JOINT SHALL BE USED IN THE TRANSITION TO ABOVE GROUND CONDUIT WHERE REQUIRED BY CEC 300.5(J).
10. ANY METAL SHAVINGS RESULTING FROM SITE WORK SHALL BE CLEANED FROM
ENCLOSURE INTERIORS, TOP SURFACES OF ENCLOSURE, ROOF SURFACE,
AND ANY ADDITIONAL AREAS WHERE OXIDATION OR CONDUCTIVE METAL
SHAVINGS MAY CAUSE RUST, ELECTRICAL SHORT CIRCUIT OR OTHER DAMAGE.
11. CONDUITS LONGER THAN 200' WITH NEGATIVE SLOPE TOWARD ELECTRICAL
EQUIPMENT SHALL HAVE A PULL BOX OR VAULT ADJACENT TO THE ENTRY POINT INTO THE ELECTRICAL EQUIPMENT.
12. WHEN TRANSITIONING FROM FREE AIR TO CONDUCTORS TO CONDUIT A LISTED FITTING SHALL BE USED TO PREVENT THE ENTRY OF MOISTURE.
13. ALL COPPER TERMINATION AC AND DC SHALL HAVE KOPR-SHIELD APPLIED.
14. ALL AC AND DC WIRING SHALL BE MEGGER TESTED BEFORE TERMINATING AT 1,000 VDC TO DEMONSTRATE A MINIMUM OF 250 MEGAOHMS RESISTANCE TO GROUND. DO NOT MEGGER THE SOLAR MODULES AS THEY WILL LIKLEY DAMAGE THEIR INTERNAL DIODES. MEGGERING IS INTENDED FOR ALL CONDUCTORS INSTALLED BY THE ELECTRICAL CONTRACTOR.
15. BENDS SHALL NOT DAMAGE THE RACEWAY OR SIGNIFICANTLY CHANGE THE INTERNAL DIAMETER OF RACEWAY (NO KINKS).
16. MODULE TO SOURCE CIRCUIT CONNECTORS MUST BE OF THE SAME MAKE AND MODEL AS THE MODULE TO MODULE CONNECTORS. THE CONNECTION TO
SOURCE CIRCUITS MUST BE PER THE MODULE MANUFACTURER AND CONNECTOR MANUFACTURER INSTRUCTIONS. CONTRACTOR TO VERIFY THAT
THE STRING CONDUCTOR DIAMETER IS COMPATIBLE WITH THE STRING CIRCUIT HOME RUN CONNECTORS.
17. SUPPORT CONDUCTORS IN VERTICAL CONDUITS IN ACCORDANCE WITH THE REQUIREMENT OF CEC 300.19.
18. ALL CRIMP TERMINATIONS SHALL BE 90 DEGREE C RATED.
19. CONNECTORS TO BE TORQUED PER DEVICE LISTING, OR MANUFACTURERS
RECOMMENDATIONS
20. SPLIT BOLTS/SPLICES/CONNECTORS SHALL BE INSULATED WITH APPROVED MEANS. UL LISTED ELECTRICAL TAPE ALONE IS NOT SUITABLE AS THE ONLY INSULATION MEANS. FOLLOW MANUFACTURERS INSTRUCTIONS FOR INSTALLATION, AND APPLICATION OF INSULATING PRODUCT.
21. ALL LV AC WIRING SHALL BE TYPE THWN-2 RATED AT 90 DEGREES C. XHHW-2 IS AN APPROVED ALTERNATE. THIS NOTE WILL BE SUPERCEDED BY ANY
INVERTER SPECIFICATIONS REQUIRING LV AC WIRE TO MEET HIGHER VOLTAGE OR INSULATION STANDARDS.
22. USE MEYERS HUB LISTED TO PROVIDE MOISTURE PROTECTION FOR CONDUIT ENTRANCES IN ALL APPLICABLE LOCATIONS AS REQUIRED BY CEC 314.15. ANY
CONDUIT ENTERING THE TOP OF AN ENCLOSURE SHALL HAVE A MYERS HUB CONNECTION.
23. PROTECT WIRE FROM SHARP EDGES WITH UV RATED SPIRAL WRAP, EDGEGUARD, OR SPLIT LOOM.
24. PROVIDE AN EQUIPMENT PAD FOR ALL ELECTRICAL EQUIPMENT. PAD IS TO EXTEND TO AT LEAST 8" OUTSIDE OF EQUIPMENT. WHERE EQUIPMENT IS NOT
INSTALLED ON LEVEL PAVEMENT, EQUIPMENT PAD IS TO BE BUILT SUCH THAT IT ENCOMPASSES THE EQUIPMENT WORKING CLEARANCE AS WELL.
9. ALL EQUIPMENT GROUNDS INSTALLED SHOULD BE COPPER ONLY
10. CEC ARTICLE 250.50 - GROUNDINGS EARTH RESISTANCE SHALL NOT EXCEED 25 OHMS. IF A SINGLE GROUND ROD, PIPE OR PLATE HAS EARTH RESISTANCE IN EXCESS OF 25 OHMS, SUPPLEMENTAL GROUNDING ELECTRODES SHALL BE ADDED AT 6FT MIN. INTERVALS ON ORDER TO ACHIEVE EARTH RESISTANCE OF LESS THAN 25 OHMS.
DAMAGE PROTECTION
1. THE ELECTRICAL CONTRACTOR SHALL CONSIDER THE WEATHERING OF
EQUIPMENT OVER TIME AND ELIMINATE THE POSSIBILITY OF DEGRADATION DUE TO CORROSION, WATER ENTRY AND UV EXPOSURE. AS A RESULT, THE USE OF
UNISTRUT OR SIMILAR MOUNTING SYSTEMS IS REQUIRED TO MOUNT
ENCLOSURES, PULL BOXES, LOAD CENTERS, FUSE BOXES, OR OTHER
EQUIPMENT
2. ALL NEMA 4 BOXES SHALL BE EQUIPPED WITH LISTED DRAIN PLUGS INSTALLED TO ALLOW WATER TO DRAIN. ANY MODIFICATION TO AS-MANUFACTURED
EQUIPMENT SHOULD BE DONE IN SUCH A WAY AS TO MAINTAIN ALL LISTED RATINGS.
3. ALL NEMA 3 BOXES SHALL BE EQUIPPED WITH A WEEP HOLE OR LISTED DRAIN
PLUGS INSTALLED TO ALLOW WATER TO DRAIN
4. ALL ELECTRICAL CONDUIT, EQUIPMENT AND COMPONENTS MUST BE
ADEQUATELY PROTECTED FROM DAMAGE AND VANDALISM BY THE USE OF BOLLARDS, SHIELDS, GUARDS OR OTHER ACCEPTABLE MEANS.
5. ALL CIRCUIT BREAKERS INSTALLED THAT ARE SUBJECT TO REVERSE POWER
FLOW SHALL BE LISTED AND LABELED AS BACKFEED COMPATIBLE
6. SOURCE CIRCUIT WIRING SHALL NOT BE SUPPORTED BY PLASTIC CABLE TIES
GROUND FAULT PROTECTION
1. PHOTOVOLTAIC INVERTERS SHALL BE EQUIPPED WITH D.C. GROUND FAULT PROTECTION TO REDUCE FIRE HAZARDS. INVERTERS ARE ALSO EQUIPPED
WITH ANTI-ISLANDING CIRCUITRY
DISCONNECTING MEANS
1. MEANS SHALL BE PROVIDED TO DISCONNECT ALL CURRENT CARRYING
CONDUCTORS OF THE PHOTOVOLTAIC POWER SOURCE FROM ALL OTHER CONDUCTORS IN THE BUILDING.
2. WHERE A CIRCUIT GROUNDING CONNECTION IS NOT DESIGNED TO BE
AUTOMATICALLY INTERRUPTED AS PART OF THE GROUND-FAULT
PROTECTION SYSTEM REQUIRED BY SECTION 690-5, A SWITCH OR CIRCUIT
BREAKER USED AS A DISCONNECTING MEANS SHALL NOT HAVE A POLE IN THE GROUNDED CONDUCTOR.
3. THE GROUNDED CONDUCTOR MAY HAVE A BOLTED OR TERMINAL
DISCONNECTING MEANS TO ALLOW MAINTENANCE OR TROUBLESHOOTING BY QUALIFIED PERSONNEL.
4. UNLESS DISCONNECT IS SERVICING A LINE-SIDE TAP, THE DISCONNECTING
MEANS SHALL NOT BE REQUIRED TO BE SUITABLE AS SERVICE EQUIPMENT AND SHALL BE RATED IN ACCORDANCE WITH SECTION 690-17.
5. EQUIPMENT SUCH AS PHOTOVOLTAIC SOURCE CIRCUITS, OVER CURRENT
DEVICES, AND BLOCKING DIODES SHALL BE PERMITTED ON THE
PHOTOVOLTAIC SIDE OF THE PHOTOVOLTAIC DISCONNECTING MEANS.
6. MEANS SHALL BE PROVIDED TO DISCONNECT EQUIPMENT SUCH AS
INVERTERS, BATTERIES, CHARGE CONTROLLERS, AND THE LIKE FROM ALL UNGROUNDED CONDUCTORS OF ALL SOURCES. IF THE EQUIPMENT IS
ENERGIZED FROM MORE THAN ONE SOURCE, THE DISCONNECTING MEANS SHALL BE GROUPED AND IDENTIFIED.
7. A SINGLE DISCONNECTING MEANS SHALL BE PERMITTED FOR THE COMBINED A.C. OUTPUT OF ONE OR MORE INVERTERS IN AN INTERACTIVE SYSTEM -
PROVIDED EACH INVERTER ASSOCIATED WITH THE DISCONNECT HAS ITS OWN INTERNAL AC DISCONNECT.
8. DISCONNECTING MEANS SHALL BE PROVIDED TO DISCONNECT A FUSE FROM
ALL SOURCES OF SUPPLY IF THE FUSE IS ENERGIZED FROM BOTH DIRECTIONS AND IS ACCESSIBLE TO OTHER THAN QUALIFIED PERSONS.
SUCH A FUSE IN A PHOTOVOLTAIC SOURCE CIRCUIT SHALL BE CAPABLE OF
BEING DISCONNECTED INDEPENDENTLY OF FUSES IN OTHER
PHOTOVOLTAIC SOURCE CIRCUITS.
9. ALL DISCONNECTS AND COMBINERS SHALL BE SECURED FROM
UNAUTHORIZED AND UNQUALIFIED PERSONNELL BY EITHER LOCK OR LOCATION.
REQUIRED SAFETY SIGNS AND LABELS
REQUIRED SAFETY SIGNS AND LABELS SHALL BE PERMAMENTLY ATTACHED BY ADHESIVE, OR OTHER MECHANICAL MEANS. LABELS SHALL COMPLY WITH ARTICLE 690 OF THE CEC OR OTHER APPLICABLE STATE AND LOCAL CODES.
SEE LABELS AND MARKING PAGE FOR MORE INFORMATION.
WEAR PPE APPROPRIATE FOR THE HAZARD: INSULATED GLOVES WITH
PROTECTORS, INSULATED MATS AND TOOLS
1. ANY SWITCH, FUSES, OR CIRCUIT BREAKERS THAT CAN BE ENERGIZED IN EITHER DIRECTION SHALL BE LABELED AS FOLLOWS:
WARNING:
ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH THE LINE AND LOAD SIDES MAY BE
ENERGIZED IN THE OPEN POSITION
2. THIS PHOTOVOLTAIC SYSTEM WILL BE EQUIPPED WITH DC DISCONNECTING COMBINERS WHICH WILL BE LABELED AS FOLLOWS:
PHOTOVOLTAIC
DISCONNECTING COMBINERS
3. THIS PHOTOVOLTAIC SYSTEM WILL BE EQUIPPED WITH AN A.C. DISCONNECT WHICH WILL BE LABELED AS FOLLOWS:
PHOTOVOLTAIC
DISCONNECTING MEANS
A.C. DISCONNECT
4. A MARKING SPECIFYING THE PHOTOVOLTAIC POWER SOURCE RATED AS
FOLLOWS SHALL BE PROVIDED AT AN ACCESSIBLE LOCATION AT THE DISCONNECTION MEANS FOR THE POWER SOURCE:
OPERATING CURRENT
OPERATING VOLTAGE
MAXIMUM SYSTEM VOLTAGE
SHORT CIRCUIT CURRENT
COMBINER
MARKINGS:
1. ALL INTERACTIVE SYSTEM POINTS OF INTERCONNECTION WITH OTHER
SOURCES SHALL BE MARKED AT AN ACCESSIBLE LOCATION AT THE DISCONNECTION MEANS.
2. A PERMANENT PLAQUE OR DIRECTORY SHALL BE PROVIDED IDENTIFYING THE
LOCATION OF THE SERVICE DISCONNECTION MEANS AND THE
PHOTOVOLTAIC SYSTEM DISCONNECTION MEANS, IF NOT LOCATED AT THE SAME LOCATION.
3. PHOTOVOLTAIC MODULES SHALL BE MARKED TO IDENTIFY LEAD POLARITY,
DEVICE RATINGS, AND SPECIFICATIONS FOR VOLTAGES, CURRENTS, AND POWER.
4. ALL REQUIRED EQUIPTMENT SHALL BE UL LISTED AND LABELED
ACCORDINGLY
DC WIRE MANAGEMENT
1. MODULE TO MODULE WIRE MANAGEMENT
1.1. CONDUCTORS SHALL BE SECURED TO MODULE FRAMES WITH STAINLESS STEEL WIRE CLIPS, CABLES OR EQUIVALENT. PLASTIC ZIP TIES ARE NOT APPROVED.
1.2. WIRE SHALL BE SECURED AND SUPPORTED AT A MINIMUM OF EVERY 4 FT OR ON EVERY MODULE.
1.3. WIRE SHALL BE SECURED IN A WAY THAT IT MAY NOT COME INTO CONTACT WITH ANY SHARP EDGES.
1.4. MODULE WIRING SHALL NOT BE UNDER STRAIN AT THE JUNCTION BOX, AND SHALL MEET ALL BENDING RADIUS REQUIREMENTS.
1.5. MODULE TO MODULE CONNECTORS, AND MODULE TO SOURCE
CONNECTORS SHALL BE SECURED OUT OF DIRECT SUNLIGHT.
2. ROW TO ROW WIRE MANAGEMENT
2.1. MODULE CIRCUITS AND STRING CIRCUITS SHALL BE PROTECTED FROM UV LIGHT AND PHYSICAL DAMAGE BETWEEN ROWS.
2.2. UNLESS OTHERWISE NOTED, THE FOLLOWING ARE SUITABLE TO PROTECT CONDUCTORS BETWEEN ROWS:
2.2.1. EMT, RMC, AND IMC CONDUIT (METAL RACEWAYS MUST USE
GROUND BUSHING AND PROTECTIVE BUSHINGS)
2.2.2. UV RESISTANT PVC CONDUIT
2.2.3. UV RESISTANT SPLIT CORRUGATED TUBING
2.2.4. UV RESISTANT LIQUID-TITE FLEXIBLE NONMETALLIC CONDUIT
2.3. WIRE SHALL BE BUNDLED SUCH THAT THE NUMBER OF
CONDUCTORS IN THE BUNDLE SHALL NOT EXCEED THE DERATED
AMPACITY OF THE CONDUCTORS.
3. CONDUIT ENTRANCE
3.1. WHERE SOURCE CIRCUITS ENTER CONDUIT THAT IS ROUTED TO
THE COMBINER BOX OR INVERTER, CONDUCTORS MUST PASS
THROUGH A WATER TIGHT STRAIN RELIEF SUCH AS THE HAYCO
MASTHEAD OR EQUIVALENT.
3.2. SOURCE CIRCUITS SHALL HAVE A "DRIP LOOP" IN THE WIRE BEFORE ENTERING THE CONDUIT.
SUPPLY SIDE TAP
1. SUPPLY SIDE TAP TO COMPLY WITH NEC 705.12(A)
2. SUPPLY SIDE TAP TO COMPLY WITH UL 891 AND CERTIFIED TO MAINTAIN THE UL LISTING OF SWITCHBOARD.
2.1 CERTIFICATION TO BE PREFORMED BY UL APPROVED INSPECTOR.
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
ELECTRICAL PV
NOTES
200102
PV0.2
AN
AN
MG
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 323 of 357
2"
1'-0"
11_
4"
3_
4"
1_
4"
2"
1'-0"
11_
4"
1"
3__
16"
11_
2"
41_
2"
3__
16"
3 7__
16"
2"
43_
4"
3__
16"
1"
43_
4"
3__
16"
41_
2"
1_
4"
3__
16"
5"
3__
16"
3__
16"
3__
16"
5"5"
1_
4"
1_
4"
1_
4"
1_
4"
TO BE PLACED AT ALL 208VAC EQUIPMENT
208 VOLTS AC
CAUTION:
POWER TO THIS SERVICE IS ALSO SUPPLIED FROM
THE FOLLOWING SOURCES WITH DISCONNECTS AS
SHOWN
TO BE PLACED "UDS" AND "ACC-1"
600 VOLTS DC
3"
TO BE PLACED AT INVERTERS
SOLAR
PHOTOVOLTAIC
INVERTER INV-#
1. LABELS AND MARKINGS SHALL BE APPLIED
TO THE APPROPRIATE COMPONENTS IN
ACCORDANCE WITH THE NEC, SUN EDISON
STANDARDS AND CAL FIRE GUIDELINES.
2. SOLAR MODULES ARE SUPPLIED FROM THE
MANUFACTURER WITH MARKINGS
PRE-APPLIED TO MEET THE REQUIREMENTS
OF THE NEC.
3. TEXT LABELS WILL BE ETCHED WITH WHITE
GRAPHICS ONTO 1/16” RED PLASTIC
PLACARDS. THE LABEL WILL BE ATTACHED
TO THE APPROPRIATE COMPONENT
ENCLOSURES IN CONSPICUOUS PLACES
USING RIVITS.
4. ALL EXPOSED RACEWAYS, COVERS FOR
PULLBOX/JUNCTION BOXES AND CONDUIT
BODIES WITH ANY AVAILABLE UNUSED
CONDUIT OPENINGS SHALL BE LABELED WITH
THE WORDING "PHOTOVOLTAIC POWER
SOURCE"
POINT OF COMMON COUPLING
POCC) PHOTOVOLTAIC LINE SIDE
TAP. FEEDER FROM DISCONNECT
UDS"
ARC FLASH SHOCK HAZARD
XX INCHES FLASH HAZARD BOUNDARY
X.XX FLASH HAZARD AT 18 INCHES
CATEGORY X CLOTHING REQUIREMENTS
480VAC WHEN COVER IS REMOVED
XX GLOVE CLASS
XX INCHES LIMITED APPROACH
XX INCHES RESTRICTED APPROACH
XX INCHES PROHIBITED APPROACH
APPROPRIATE PPE REQUIRED
PROVIDE INPUT FROM ARC FLASH REPORT
PROVIDE SIGNAGE AT ALL DB1, ACC1, AND UDS
WARNING
ELECTRIC SHOCK HAZARD.
THE DC CONDUCTORS OF THIS
PHOTOVOLTAIC SYSTEM ARE
UNGROUNDED AND MAY BE
ENERGIZED.
TO BE PLACED AT EACH JUNCTION BOX,
COMBINER BOX, DISCONNECT, AND DEVICE
WHERE ENERGIZED, UNGROUNDED CIRCUITS
MAY BE EXPOSED DURING SERVICE
NO ADDITIONAL LOADS MAY BE
ADDED TO THIS SWITCHBOARD.
TO BE PLACED AT ALL 600VDC EQUIPMENT
TO BE PLACED AT DB1 AT POCC
TO BE PLACED AT "ACC-1"
6"
TO BE PLACED AT UTILITY DISCONNECT "UDS"
PHOTOVOLTAIC SYSTEM UTILITY
WARNING:
ELECTRIC SHOCK HAZARD. DO NOT TOUCH
TERMINALS. TERMINALS ON BOTH LINE AND
LOAD SIDE MAY BE ENERGIZED IN THE OPEN
POSITION
AC DISCONNECT RATINGS:
OPERATING CURRENT: 200A
OPERATING VOLTAGE: 208V/3P
MAXIMUM CURRENT: 250A
MAXIMUM VOLTAGE: 600V
SAFETY DISCONNECT SWITCH
6"
TO BE PLACED AT INVERTER INV-1, INV-2, INV-3 AND INV-4
CAUTION:
TERMINALS ON BOTH LINE AND LOAD SIDE
MAY BE ENERGIZED WHEN PHOTOVOLTAIC
MODULES ARE EXPOSED TO SUNLIGHT.
WARNING:
ELECTRIC SHOCK HAZARD IF A GROUND
FAULT IS INDICATED, NORMALLY GROUNDED
CONDUCTORS MAY BY UNGROUNDED AND
ENERGIZED.
MAXIMUM VOLTAGE: 600VDC
MAXIMUM CURRENT: 180ADC
OPERATING VOLTAGE: 450VDC
OPERATING CURRENT: 137.3ADC
PV ARRAYS
MAIN ELECTRICAL
ROOM
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
ELECTRICAL PV
LABELS
200102
PV0.3
AN
AN
MG
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 324 of 357
S2-3S1-3
S1-4 S2-4 S3-4 S4-4 S5-4 S6-4
S1-1
S2-1S3-1
S4-1
S5-1
S6-1
S1-2
S2-2
S3-2
S4-2
S5-2
S6-2
S7-2
S7-1
INVERTER MPPT STRING
MODULE
CONFIGURATION
INV-1
42kW
1 11
2 3
4 5
6 7
8-24 NOT USED
1 2
3 4
5 6
7 8-24
11 11
11 11
11 11
INVERTER MPPT STRING
MODULE
CONFIGURATION
INV-2
42kW
1 11
2 3
4 5
6 7
1 2
3 4
5 6
7 11
11 11
11 11
11 INVERTER MPPT STRING
MODULE
CONFIGURATION
INV-3
42kW
1 7
2 3-24 NOT USED
1 2
3-24
7 INVERTER MPPT STRING
MODULE
CONFIGURATION
INV-4
42kW
1 9
2 3
4 5
6 7-24 NOT USED
1 2
3 4
5 6
7-24
9 9
9 9
9 8-24 NOTUSED8-24
ACC-1
INV-1
INV-2
INV-3
INV-4
2 G
E
J
F
H
3 C
A
641
B
5 D
7 8 9 10 AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
SOLAR LAYOUT
200102
PV1.0
Checker
AN
MG
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 325 of 357
FEEDER RACEWAY AND CONDUCTORS
NOTE
VOLTS
FED FROM
MOUNTING
ROOM
CBCIRCUITDESCRIPTION
LOAD KVACKTBREAKER
TRIP/POLES A
NEUTRAL
BUS AMPS
AIC
MAIN BKR
LUGS
TOTAL CONNECTED KVA BY PHASE
FEEDER RACEWAY AND CONDUCTORS
NOTE
VOLTS
FED FROM
MOUNTING
ROOM
CBCIRCUITDESCRIPTION
LOAD KVACKTBREAKER
TRIP/POLES A
NEUTRAL
BUS AMPS
AIC
MAIN BKR
LUGS
TOTAL CONNECTED KVA BY PHASE
208Y/120V 3P 4W
SURFACE
ACC-2
MSB STANDARD
150
22,000
150
100%
1-1/2"C,3#1,#1N,#8G1.87100/3 1.87 1.87
1-1/2"C,3#1/0,#1/0N,#6G7.2100/3 7.2 7.2
0-/3 0 0
0-/3 0 0
9.079.079.07
27.2 34 34
94.4 A
INV-3
INV-4
SPACE
SPACE
208Y/120V 3P 4W
SURFACE
ACC-1
DB1 STANDARD
250
22,000
250
100%
1-1/2"C,3#1/0,#1/0N,#6G10.3125/3 10.3 10.3
1-1/2"C,3#1/0,#1/0N,#6G10.3125/3 10.3 10.3
0-/3 0 0
0-/3 0 0
20.520.520.5
61.6 77 77
214 A
INV-1
INV-2
SPACE
SPACE
1 2
3 4
CONN
KVA
CALC
KVA
CALC
KVA
CONTINUOUS (125%) TOTAL LOAD
BALANCED 3-PHASE LOAD
1 2
3 4
CONN
KVA
CALC
KVA
CALC
KVA
CONTINUOUS (125%) TOTAL LOAD
BALANCED 3-PHASE LOAD
FAULT CURRENT SCHEDULE
DEVICE FAULT AIC
RATING
L-N
VOLTS
UTILITY
FAULT X R
FED FROM
DEVICE FAULT X R
FEEDER
SIZE X / 1000' R / 1000' LENGTH X R
DB1 42,000 42,000 120V 42,000 0.002802 0.0005603 (2)#350kcmil0.02 0.019 0 0 ACC-1 18,661 22,000 120V 18,661 0.005268 0.003688 DB1 42,000 0.002802 0.0005603 #250kcmil 0.041 0.052 60' 0.0025 0.0031 INV-1 14,450 22,000 120V 14,450 0.006015 0.005726 ACC-1 18,661 0.005268 0.003688 #1/0 0.044 0.12 17' 0.0007 0.002 INV-2 12,645 22,000 120V 12,645 0.006463 0.006949 ACC-1 18,661 0.005268 0.003688 #1/0 0.044 0.12 27' 0.0012 0.0033 MSB 42,000 42,000 120V 42,000 0.002802 0.0005603 (3)#600kcmil0.013 0.0077 0 0 ACC-2 13,185 22,000 120V 13,185 0.005307 0.007393 MSB 42,000 0.002802 0.0005603 #1/0 0.044 0.12 57' 0.0025 0.0068 INV-3 2,766 22,000 120V 2,766 0.01547 0.04053 ACC-2 13,185 0.005307 0.007393 #1 0.046 0.15 221' 0.0102 0.0331 INV-4 2,207 22,000 120V 2,207 0.02099 0.05015 ACC-2 13,185 0.005307 0.007393 #1/0 0.044 0.12 356' 0.0157 0.0428
FEEDER SCHEDULE
FEEDER
AMPS
CONDUIT AND FEEDER FEEDING THESE DEVICES
100 1-1/2"C,3#1,#1N,#8G INV-3
125 1-1/2"C,3#1/0,#1/0N,#6G INV-1, INV-2, INV-4
150 1-1/2"C,3#1/0,#1/0N,#6G ACC-2
250 2-1/2"C,3#250kcmil,# 250kcmil N,#4G ACC-1
SIZING METHOD: COPPER AND ALUMINUM, 60°C #12 THROUGH #1, 75°C 1/0 AND ABOVE
VOLTAGE DROP SCHEDULE
DEVICE FEEDER
VOLTAGE DROP WIRE SIZE
DB1 0% (2)#350kcmil
ACC-1 0.7% #250kcmil
INV-1 0.89% #1/0
INV-2 1.01% #1/0
MSB 0% (3)#600kcmil
ACC-2 0.33% #1/0
INV-3 0.81% #1
INV-4 2.93% #1/0
M M
PANEL "ACC-1"
SINGLE LINE DIAGRAM
SCALE: NONE
INV-1INV-1
G
G N
INV-1INV-2
G
G N
G
N
1 AC AND DC DISCONNECTS ARE INTEGRAL TO
INVERTER.
2 2 2
TYPICAL INVERTER CONNECTION. SEE PANEL
SCHEDULES ON THIS SHEET FOR CONDUIT
AND CONDUCTOR SIZES. SEE SHEET PV2.1
FOR TYPICAL INVERTER CONNECTION DETAIL
AND SHEET PV3.0 FOR CUT SHEET
INFORMATION.
3 3 3
SEE PANEL SCHEDULE ON THIS SHEET FOR
PANEL AND MAIN BREAKER CHARACTERISTICS.
1 250A, 208Y/120V, 3PH, 4W
125A
3P
125A
3P
UTILITY DISCONNECT "UDS1"
600V, 250A WITH VISIBLE BLADES
250A
208Y/120V
TO MSB
TO MSB
PANEL "ACC-2"
G
N
1 INV-1INV-3
G
G N
2 3
150A, 208Y/120V, 3PH, 4W
100A
3P
TO DB1
INV-1INV-3
G
G N
2 3
100A
3P
BUILDING B-1 BUILDING B-2 CAR PORT-1 CAR PORT-2
UTILITY DISCONNECT "UDS2"
600V, 150A WITH VISIBLE BLADES
150A
208Y/120V
TO DB1
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
PV SINGLE LINE
DIAGRAM
200102
PV2.0
AN
AN
MG
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 326 of 357
INVERTER
GROUND
6CU.
10CU.
PV STRINGS#6CU.
BOND TO
RACKING
DC SCHEMATIC DESIGN - GROUNDING SCHEMATIC
SCALE: NONE
UL LISTED GROUNDING
HARDWARE. PROVIDE
2) FOR EVERY
MODULE. (TYPICAL)
DC SCHEMATIC DIAGRAM - STRING CONNECTION DETAIL
SCALE: NONE
STRUCTURE
G
6 7 834521
GROUND LUGS ATTACHED
TO MOUNTING STRUCTURE.
ROUTE CONDUCTORS WITH STRUCTURE. CONCEAL
CONDUCTORS BEHIND STRUCTURE WHERE
POSSIBLE. PROVIDE (2) #10 CU. PER STRING. CABLE
TO BE PV WIRE FOR UNGROUNDED PV SYSTEMS.
PROVIDE (1) #10 BARE CU. E.G. AND BOND TO EACH
STRING. (TYPICAL FOR EACH STRING).
INVERTER
SEE SHEET
PV3.0 FOR
INVERTER CUT
SHEETS
TO AC COMBINER BOARDS
GROUND AT MODULE WITH
LUGS AT GROUNDING
LOCATION ONLY. PER
MODULE INSTALLATION
MANUAL. PROVIDE
CONTINUOUS MODULE
BOND WIRE
ALL DC WIRING SHALL BE 1000VDC PV
WIRE TYPE INSULATION.
RED STRIPE ON POSITIVE WIRES AND
YELLOW STRIPE ON NEGATIVE.
NOTE:
ALL AC CONDUCTORS ARE THWN-2.
ALL DC CONDUCTORS ARE PV WIRE.
PROVIDE POWER
TERMINAL LUGS IN
A WP J-BOX WHEN
CONDUCTORS
EXCEED INVERTER
LUG SIZES.
UL LISTED GROUNDING
HARDWARE. PROVIDE
2) FOR EVERY
MODULE. (TYPICAL)
TO ADDITIONAL
STRINGS. SEE
SHEET PV1.0.
G+-COMBINER BOX
REQUIRED FOR 2
STRING INPUTS PER
MPPT)
N
9 10 11
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
DC SCHEMATIC
DIAGRAM
200102
PV2.1
AN
AN
MG
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 327 of 357
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
PV
SPECIFICATIONS
200102
PV3.0
AN
AN
MG
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 328 of 357
AN
TON
N A T H A
NSON
Exp. 03/31/ 21
LATRICECLE
REEREGISTERED
PROFESSIONAL
ENGIN
STATE OF CALIFORNIA
No. E 21090
9150 CHESAPEAKE DR, STE 220
SAN DIEGO, CA 92123
www.ELENconsulting.com
Description: Date:
Project Number:
Drawn By:
Checked By:
Sheet Title:
Approved By:
PROJECT:
6353 DEL CERRO BLVD., SAN DIEGO, CA 92120
619.698.9177 | www.jeffkatzarchitecture.com
005-104
FOR CONSTRUCTION
PV
CALCULATIONS
200102
PV4.0
AN
AN
MG
ADMINISTRATION
BUILDING
CITY OF VISTA PUBLIC
WORKS DEPARTMENT
1165 E TAYLOR ST.
VISTA, CA 92084
FOR
CONSTRUCTION
05/ 18/21
BLDG DEPT
SUBMITTAL
09/ 02/20
BLDG DEPT
RESUBMITTAL
11/ 25/20
BID SET 02/ 11/21
11/10/2026 C6 329 of 357
EXHIBIT 4
Project Site
11/10/2026 C6 330 of 357
ProProposed
BUILDING C IMPROVEMENTS
APPENDIX C
11/10/2026 C6 331 of 357
EXHIBIT 5
Agreement to Comply With California Labor Law Requirements 11/10/2026 C6 332 of 357
00052253 1
AGREEMENT TO COMPLY WITH CALIFORNIA LABOR LAW REQUIREMENTS Labor Code §§ 1720, 1771.1, 1773.8, 1775, 1776, 1777.5, 1813, 1860, 1861, 3700] The undersigned Contractor certifies that it is aware of and hereby agrees to fully comply with the following provisions of California law:
1.No contractor or subcontractor may be listed on a bid proposal for a public works project unless registered with the Department of Industrial Relations pursuant to Labor Code section 1725.5 [with limited exceptions from this requirement for bid purposes only under Labor Code section 1771.1(a)]. No contractor or subcontractor of any tier may be awarded a contract for public work on a public works project without proof of registration with the Department of Industrial Relations pursuant to Labor Code section 1725.5.
This project is subject to compliance monitoring and enforcement by the Department of Industrial Relations.
2.Contractor acknowledges that this contract is subject to the provisions of Division 2, Part 7, Chapter 1 (commencing with Section 1720) of the California Labor Code relating to public works and the awarding public agency (“Agency”) and agrees to be bound by all the provisions thereof as though set forth in full herein.
3.Contractor agrees to comply with the provisions of California Labor Code Section 1773.8 which requires the payment of travel and subsistence payments to each worker needed to execute the work to the extent required by law.
4.Contractor agrees to comply with the provisions of California Labor Code Sections 1774 and 1775 concerning the payment of prevailing rates of wages to workers and the penalties for failure to pay prevailing wages. The Contractor shall, as a penalty to the Agency, forfeit not more than fifty dollars ($50) for each calendar day, or portion thereof, for each worker paid less than the prevailing rates as determined by the Director of Industrial Relations for the work or craft in which the worker is employed for any public work done under the contract by Contractor or by any subcontractor.
5.Contractor agrees to comply with the provisions of California Labor Code Section 1776 which require Contractor and each subcontractor to (1) keep accurate payroll records, (2) certify and make such payroll records available for inspection as provided by Section 1776, and (3) inform the Agency of the location of the records. The Contractor is responsible for compliance with Section 1776 by itself and all of its subcontractors.
6.Contractor agrees to comply with the provisions of California Labor Code Section 1777.5 concerning the employment of apprentices on public works projects, and further agrees that Contractor is responsible for compliance with Section 1777.5 by itself and all of its subcontractors.
7.Contractor agrees to comply with the provisions of California Labor Code Section 1813 concerning penalties for workers who work excess hours. The Contractor shall, as a penalty to the Agency, forfeit twenty-five dollars ($25) for each worker employed in the execution of the contract by the Contractor or by any subcontractor for each calendar day during which such worker is required or permitted to work more than 8 hours in any one calendar day and 40 hours in any one calendar week in violation of the provisions of Division 2, Part 7, Chapter 1, Article 3 of the California Labor Code.
8.Registrations under Section 1725.5 expire annually at the end of June, and Contractor is responsible for verifying the renewal status of each subcontractor, of any tier, working on this Contract, and providing City with an updated list of all subcontractors and their registration status. Subcontractors who do not timely renew their registration must be removed from the job site until they are registered. The removal of a subcontractor for failure to be registered shall not be cause for any extension of time or additional compensation of any nature under the Contract.
9.Contractor shall provide to City, as a condition precedent to the payment of Contractor’s final retention, a complete list of all subcontractors who have worked on the Project, including their registration numbers. This list must be provided at least 30 days prior to the payment of the final retention and shall be submitted under penalty of perjury.
11/10/2026 C6 333 of 357
00052253 1
10.To the fullest extent permitted by law and without limitation by the other provisions of this Contract relating to indemnification and insurance, Contractor shall also indemnify, defend and hold harmless City, and its directors, officers, employees and agents from and against all liability, excluding penalties assessed against City under Labor Code Section 1773.3, but including, without limitation, associated investigation and administrative expenses, defense costs, reasonable attorneys' fees, expert witnes s fees, court costs, and costs of alternative dispute resolution, resulting from Contractor’s failure to comply with the provisions of this section and of Article 2, Chapter 1, Part 7, Division 2 of the California Labor Code with respect to Contractor, all subcontractors of any tier, and their respective employees working under this Contract.
11.California Labor Code Sections 1860 and 3700 provide that every contractor will be required to secure the payment of compensation to its employees. In accordance with the provisions of California Labor Code Section 1861, Contractor hereby certifies as follows:
I am aware of the provisions of Section 3700 of the Labor Code which require every employer to be insured against liability for worker’s compensation or to undertake self-insurance in accordance with the provisions of that code, and I will comply with such provisions before commencing the performance of the work of this contract.”
Signature Date
Name/Title Company:
11/10/2026 C6 334 of 357
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS.
INSURER(S) AFFORDING COVERAGE
INSURER F :
INSURER E :
INSURER D :
INSURER C :
INSURER B :
INSURER A :
NAIC #
NAME:
CONTACT
A/C, No):
FAX
E-MAIL
ADDRESS:
PRODUCER
A/C, No, Ext):
PHONE
INSURED
REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s).
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
OTHER:
Per accident)
Ea accident)
N / A
SUBR
WVD
ADDL
INSD
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
PROPERTY DAMAGE
BODILY INJURY (Per accident)
BODILY INJURY (Per person)
COMBINED SINGLE LIMIT
AUTOS ONLY
AUTOSAUTOSONLY
NON-OWNED
SCHEDULEDOWNED
ANY AUTO
AUTOMOBILE LIABILITY
Y / N
WORKERS COMPENSATION
AND EMPLOYERS' LIABILITY
OFFICER/MEMBER EXCLUDED?
Mandatory in NH)
DESCRIPTION OF OPERATIONS below
If yes, describe under
ANY PROPRIETOR/PARTNER/EXECUTIVE
E.L. DISEASE - POLICY LIMIT
E.L. DISEASE - EA EMPLOYEE
E.L. EACH ACCIDENT
ER
OTH-
STATUTE
PER
LIMITS(MM/DD/YYYY)
POLICY EXP
MM/DD/YYYY)
POLICY EFF
POLICYNUMBERTYPEOFINSURANCELTR
INSR
DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required)
EXCESS LIAB
UMBRELLA LIAB $EACH OCCURRENCE
AGGREGATE
OCCUR
CLAIMS-MADE
DED RETENTION $
PRODUCTS - COMP/OP AGG
GENERAL AGGREGATE
PERSONAL & ADV INJURY
MED EXP (Any one person)
EACH OCCURRENCE
DAMAGE TO RENTED
PREMISES (Ea occurrence)
COMMERCIAL GENERAL LIABILITY
CLAIMS-MADE OCCUR
GEN'L AGGREGATE LIMIT APPLIES PER:
POLICY
PRO-
JECT LOC
CERTIFICATE OF LIABILITY INSURANCE
DATE (MM/DD/YYYY)
CANCELLATION
AUTHORIZED REPRESENTATIVE
ACORD 25 (2016/03)
1988-2015 ACORD CORPORATION. All rights reserved.
CERTIFICATE HOLDER
The ACORD name and logo are registered marks of ACORD
HIRED
AUTOS ONLY
1/20/2026
Kirk Miller Insurance Agency, Inc.
10636 Scripps Summit Court #110
San Diego CA 92131
Jodi Hollow
858) 240-2593
[email protected]
Firestone Builders, Inc
751 Rancheros Drive #9
San Marcos CA 92069-3043
SCOTTSDALE INS CO 41297
TRUCK INS EXCHANGE 21652
STATE COMPENSATION INS FUND 35076
25.26 Master
A BI/PD DED @ $5K Per Occ Y Y BCS2002688 06/01/2025 06/01/2026 1,000,000
100,000
Excluded
1,000,000
2,000,000
2,000,000
B Y Y 604742329 06/01/2025 06/01/2026
2,000,000
A
0 XLS2007199 06/01/2025 06/01/2026
5,000,000
5,000,000
C Y 9263541-2024 11/14/2025 11/14/2026
1,000,000
1,000,000
1,000,000
City of Vista and Buena Sanitation District are named as additional insured.
City of Vista and
Buena Sanitation District
200 Civic Center Drive
Vista CA 92084
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 335 of 357
POLICY NUMBER: CA00005668201 COMMERCIAL GENERAL LIABILITY CG 20 10 12 19
THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY.
CG 20 10 12 19 © Insurance Services Office, Inc., 2018 Page 1 of 2 ADDITIONAL INSURED – OWNERS, LESSEES OR
CONTRACTORS – SCHEDULED PERSON OR
ORGANIZATION
This endorsement modifies insurance provided under the following:
COMMERCIAL GENERAL LIABILITY COVERAGE PART
SCHEDULE
Name Of Additional Insured Person(s)
Or Organization(s) Location(s) Of Covered Operations
Information required to complete this Schedule, if not shown above, will be shown in the Declarations.
A.Section II – Who Is An Insured is amended to
include as an additional insured the person(s) or
organization(s) shown in the Schedule, but only
with respect to liability for "bodily injury", "property damage" or "personal and advertising injury"
caused, in whole or in part, by:
1.Your acts or omissions; or
2.The acts or omissions of those acting on your
behalf;
in the performance of your ongoing operations for
the additional insured(s) at the location(s)
designated above.
However:
1.The insurance afforded to such additional
insured only applies to the extent permitted by
law; and
2. If coverage provided to the additional insured is
required by a contract or agreement, the
insurance afforded to such additional insured
will not be broader than that which you are
required by the contract or agreement to
provide for such additional insured.
B.With respect to the insurance afforded to these
additional insureds, the following additional
exclusions apply:
This insurance does not apply to "bodily injury" or
property damage" occurring after:
1.All work, including materials, parts or
equipment furnished in connection with such
work, on the project (other than service,
maintenance or repairs) to be performed by or
on behalf of the additional insured(s) at the
location of the covered operations has been
completed; or
2.That portion of "your work" out of which the
injury or damage arises has been put to its
intended use by any person or organization
other than another contractor or subcontractor
engaged in performing operations for a
principal as a part of the same project.
Any person or organization that is an owner, lessee or manager of real property or personal property on which you are
performing ongoing operations, or a contractor on whose behalf you are performing ongoing operations, but only if coverage as an additional insured is required by a written contract or written agreement that is an “insured contract”, and provided the “bodily injury” or “property damage” first occurs, or the “personal and advertising injury” offense is first committed, subsequent to the execution of the contract or agreement.
All locations at which the Named Insured is performing
ongoing operations.
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 336 of 357
C.With respect to the insurance afforded to these
additional insureds, the following is added to
Section III – Limits Of Insurance:
If coverage provided to the additional insured is
required by a contract or agreement, the most we
will pay on behalf of the additional insured is the
amount of insurance:
1.Required by the contract or agreement; or
2.Available under the applicable limits of
insurance;
whichever is less.
This endorsement shall not increase the
applicable limits of insurance.
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 337 of 357
POLICY NUMBER: CA00005668201 COMMERCIAL GENERAL LIABILITY CG 20 37 12-19
THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY.
CG 20 37 12-19 © Insurance Services Office Inc. 2018 Page 1 of 1
ADDITIONAL INSURED - OWNERS, LESSEES OR
CONTRACTORS - COMPLETED OPERATIONS
This endorsement modifies insurance provided under the following:
COMMERCIAL GENERAL LIABILITY COVERAGE PART
PRODUCTS/COMPLETED OPERATIONS LIABILITY COVERAGE PART
SCHEDULE
Name Of Additional Insured Person(s)
Or Organization(s)Location And Description Of Completed Operations Any person or organization that is an owner, lessee or
manager of real property or personal property for
whom you work or have worked, or a contractor on
whose behalf you work or have worked, but only if
coverage as an additional insured extending to "bodily
injury" or "property damage" included in the "products- completed operations hazard" is required by a written
contract or written agreement that is an "insured
contract" and provided that the "bodily injury" or
property damage" first occurs subsequent to the
execution of the contract or agreement.
All locations except locations where "your work" is or
was related to a job or project involving single-family dwellings, multi-family dwellings (other than rental
apartments in an apartment building: (a) originally
constructed and at all times used for such purpose, or
b) converted from a commercial building),
condominiums, townhomes, townhouses, timeshare
units, fractional-ownership units, cooperatives and/or
any other structure or space used or intended to be
used as a residence.
A. Section II - Who Is An Insured is amended to
include as an additional insured the person(s) or
organization(s) shown in the Schedule, but only
with respect to liability for "bodily injury" or
property damage" caused, in whole or in part, by
your work" at the location designated and
described in the Schedule of this endorsement
performed for that additional insured and included
in the "products-completed operations hazard".
However:
1.The insurance afforded to such additional
insured only applies to the extent permitted by
law; and
2.If coverage provided to the additional insured is
required by a contract or agreement, the
insurance afforded to such additional insured
will not be broader than that which you are
required by the contract or agreement to
provide for such additional insured.
B.With respect to the insurance afforded to these
additional insureds, the following is added to
Section III - Limits Of Insurance:
If coverage provided to the additional insured is
required by a contract or agreement, the most we
will pay on behalf of the additional insured is the
amount of insurance:
1.Required by the contract or agreement; or
2.Available under the applicable limits of
Insurance;
whichever is less.
This endorsement shall not increase
the applicable limits of Insurance.
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 338 of 357
POLICY NUMBER:COMMERCIAL GENERAL LIABILITY
CG 24 04 12 19
THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY.
CG 24 04 12 19 © Insurance Services Office, Inc., 2018 Page 1 of 1
WAIVER OF TRANSFER OF RIGHTS OF RECOVERY
AGAINST OTHERS TO US (WAIVER OF SUBROGATION)
This endorsement modifies insurance provided under the following:
COMMERCIAL GENERAL LIABILITY COVERAGE PART
ELECTRONIC DATA LIABILITY COVERAGE PART
LIQUOR LIABILITY COVERAGE PART
POLLUTION LIABILITY COVERAGE PART DESIGNATED SITES
POLLUTION LIABILITY LIMITED COVERAGE PART DESIGNATED SITES
PRODUCTS/COMPLETED OPERATIONS LIABILITY COVERAGE PART
RAILROAD PROTECTIVE LIABILITY COVERAGE PART
UNDERGROUND STORAGE TANK POLICY DESIGNATED TANKS
SCHEDULE
Name Of Person(s) Or Organization(s):
Information required to complete this Schedule, if not shown above, will be shown in the Declarations.
The following is added to Paragraph 8. Transfer Of
Rights Of Recovery Against Others To Us of
Section IV – Conditions:
We waive any right of recovery against the person(s)
or organization(s) shown in the Schedule above
because of payments we make under this Coverage
Part. Such waiver by us applies only to the extent that the insured has waived its right of recovery against
such person(s) or organization(s) prior to loss. This
endorsement applies only to the person(s) or
organization(s) shown in the Schedule above.
MWZY 316684 23 Messer Industries USA, Inc. 03/01/23 - 03/01/24 Any person or organization as required in a written contract or agreement BCS2002688
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 339 of 357
THIS ENDORSEMENT CHANGES THE POLICY.PLEASE READ IT CAREFULLY.
J7120
1st Edition
BUSINESS AUTO EXTENSIONS
This endorsement modifies insurance provided under the following:
BUSINESS AUTO COVERAGE FORM
With respect to coverage provided by this endorsement,the provisions of the Coverage Form apply unless modified by this endorsement.
Section II -Liability Coverage is amended as follows:A.
1.The following is added to Paragraph A.1.Who Is An Insured:
Blanket Additional Insured
Each person or organization with whom you agree,by virtue of a written contract or agreement, to provide insurance is an "insured",but only with respect to their legal liability for actsoromissionsofapersonforwhomLiabilityCoverageisaffordedunderthispolicy:
1)Provided that the contract or agreement is signed and executed by you prior to the "bodily injury"or "property damage"loss;and
2)The contract or agreement is in effect during the policy period.
Section IV -Business Auto Conditions is amended as follows:B.
1.The following is added to Paragraph A.5.Transfer Of Rights Of Recovery Against Other To Us:
Blanket Waiver Of Subrogation
We waive our right of recovery that we may have against a person or organization,but only to the extent that this is required of you by a written contract or agreement that is signed andexecutedpriortoany"accident"or "loss".This waiver applies only to the person or organization designated in such contract or agreement.
2.The following is added to Paragraph B.5.Other Insurance:
Primary And Noncontributory
This insurance will be primary and will not seek contribution from any other insurance available to an additional insured under your policy provided that:
1)The additional insured is a Named Insured under such other insurance; 2)You have agreed in writing in a contract or agreement that this insurance would be primary and would not seek contribution from any other insurance available to theadditionalinsured; 3)This contract or agreement is signed and executed by you prior to when the "bodily injury"or property damage"occurs;and
4)This written contract or agreement is in effect during the policy period.
This endorsement is part of your policy.It supersedes and controls anything to the contrary.It is otherwise subject to all the terms of the policy.
93-7120 1ST EDITION 9-15 Includes copyrighted material of Insurance Services Office, Inc., with its permission.J7120101 PAGE 1 OF 1 POLICY NUMBER: 604742329
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 340 of 357
POLICY NUMBER:
COMMERCIAL AUTOCA 20 48 02 99THIS ENDORSEMENT
CHANGES THE POLICY. PLEASE READ IT CAREFULLY.CA
20 48 02 99Copyright,
Insurance Services Office,
Inc., 1998 Page 1
of 1oo DESIGNATED
INSUREDThis endorsement modifies insurance provided under the following:BUSINESS AUTO COVERAGE FORM GARAGE COVERAGE FORM MOTOR
CARRIER COVERAGE FORM TRUCKERS
COVERAGE FORM With respect to coverage provided by this endorsement, the provisions of the Coverage Form apply unless modified by this endorsement.This endorsement identifies person(s) or organization(s) who are "insureds" under the Who Is An Insured Provi-sion of the Coverage Form. This endorsement does not alter coverage provided in the
Coverage Form.This endorsement
changes the
policy effective
on the inception date of the policy unless another date is indi-cated below.Endorsement Effective:Countersigned By:Named Insured:Authorized Representative)
SCHEDULEName of Person(s) or Organization(s):(If no entry appears above, information required to complete this endorsement will be shown in the Declarations as applicable to the endorsement.)Each person or organization shown in the Schedule is an "insured"
for Liability Coverage,
but
only to the
extent that person
or organization qualifies as an "insured" under the
11/10/2026 C6 341 of 357
Name Of Person(s) Or Organization(s):
Additional Premium $
THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY.
E3153
1st Edition
CHANGES IN TRANSFER OF
RIGHTS OF RECOVERY AGAINST OTHERS TO US
WAIVER OF SUBROGATION)
This endorsement modifies insurance provided under the following:
BUSINESS AUTO COVERAGE FORM
GARAGE COVERAGE FORM
TRUCKERS COVERAGE FORM
With respect to coverage provided by this endorsement, the provisions of the Coverage Form apply unless modified by the endorsement.
This endorsement changes the policy effective on the inception date of the policy unless another date is indicated below.
Endorsement Effective:Countersigned By:
Named Insured:
Authorized Representative)
SCHEDULE
If no entry appears above, information required to complete this endorsement will be shown in the Declarations as applicable to this endorsement.)
The Transfer Of Rights Of Recovery Against Others To Us Condition does not apply to the person(s) or organization(s) shown in the Schedule. We will retain the additional premium shown above, regardless of any early termination of this endorsement or the policy.
E3153-ED1 6-06 Page 1 of 1
91-3153 E3153101
This endorsement is part of your policy. It supersedes and controls anything to the contrary. It is otherwise subject to all the terms of the policy.
CITY OF VISTA
FIRESTONE BUILDERS, INC
10/11/2021
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 342 of 357
XLS-D-1 01-21
COMMERCIAL EXCESS LIABILITY POLICY
18700 North Hayden Road · Scottsdale, Arizona 85255
1-800-423-7675
A STOCK COMPANY
ITEM 1. NAMED INSURED(S) AND MAILING ADDRESS AGENT NAME AND ADDRESS ITEM 2. POLICY PERIOD From:
12:01 A.M. Standard Time at your mailing address shown above.
DECLARATIONS
Policy Number
THIS COMMERCIAL EXCESS LIABILITY DECLARATIONS WITH THE COVERAGE FORM AND ENDORSEMENTS, IF ANY, COMPLETE THE ABOVE-NUMBERED POLICY.
Renewal of Number
To: 06/01/2026
Rate: _____________________________Per:
Policy Minimum Premium ................................................................................ $ Audit Period: Annually Other:
ITEM 7.ENDORSEMENTS ATTACHED TO THE POLICY AT INCEPTION:
See Schedule of Forms and Endorsements
New
CRC INSURANCE SERVICES
50 CALIFORNIA ST STE 2000
SAN FRANCISCO CA 94111-4703
06/01/2025
5,000,000
5,000,000
32,223
X
X
XLS2007199
In return for the payment of the premium, and subject to all the terms of this policy, we agree to provide you with the insurance as stated in this policy.
ITEM 3. THE NAMED INSURED IS: q Individual q Partnership q Corporation q Joint Venture q Other ITEM 4.LIMIT(S) OF INSURANCE:
A.Each Occurrence ............................................................................................ $ ___________________________ B. Aggregate ....................................................................................................... $ __________________________ ITEM 5.SCHEDULE OF CONTROLLING UNDERLYING INSURANCE:
See Schedule of Controlling Underlying Insurance
ITEM 6.PREMIUM COMPUTATION:
q Flat Premium:$ __________________________
q Subject to Adjustment:
Estimated Deposit Premium ..............................................................................$ __________________________ Estimated Exposure Base: ___________________________________________ FIRESTONE BUILDERS, INC.
751 RANCHEROS DR STE 9
SAN MARCOS CA 92069-3043
Agent No.04747 Program No.
Summary ofChargesSummaryofChargesSummaryofChargesSummaryofCharges Premium $32,223.00Premium $32,223.00Premium $32,223.00Premium $32,223.00 CRC Broker Fee $1,000.00CRCBrokerFee $1,000.00CRCBrokerFee $1,000.00CRCBrokerFee $1,000.00 CA Surplus Lines Tax $966.69CASurplusLinesTax $966.69CASurplusLinesTax $966.69CASurplusLinesTax $966.69 CA Stamping Office Fee $58.00CAStampingOfficeFee $58.00CAStampingOfficeFee $58.00CAStampingOfficeFee $58.00 Total $34,247.69Total $34,247.69Total $34,247.69Total $34,247.69 Zip Code92069ZipCode92069ZipCode92069ZipCode92069
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 343 of 357
UTS-SP-2L 12-95 Page 1 of 2
SCHEDULE OF FORMS AND ENDORSEMENTS
Policy No.Effective Date:
12:01 A.M., Standard Time
Named Insured Agent No.FIRESTONE BUILDERS, INC.
XLS2007199 06/01/2025
04747
IL N 018 01-22 CALIFORNIA FRAUD STATEMENT
NOTS0623CA 01-20 IMPORTANT NOTICE TO CALIFORNIA INSURED (D-2) NOTX0146CW 07-21 NOTICE TO POLICYHOLDERS RESTRICTIONS OF COVERAGE NOTX0178CW 03-16 CLAIM REPORTING INFORMATION
UTS-COVPG 03-21 COVER PAGE
XLS-D-1 01-21 COMMERCIAL EXCESS LIABILITY POLICY DECLARATIONS UTS-SP-2L 12-95 SCHEDULE OF FORMS AND ENDORSEMENTS
UTS-119g 06-14 MINIMUM EARNED CANCELLATION PREMIUM
UTS-74g 08-95 PUNITIVE OR EXEMPLARY DAMAGE EXCLUSION
UTS-9g 06-22 SERVICE OF SUIT CLAUSE
UTS-BR-606 12-22 LIMITATION OF COVERAGE-TWO OR MORE COVERAGE FORMS OR
POLICIES ISSUED BY US
XLS-SP-2 11-08 COMMERCIAL EXCESS LIABILITY SUPPLEMENTARY SCHEDULE OF
CONTROLLING UNDERLYING INSURANCE
CX 21 33 01-15 EXCLUSION OF CERTIFIED ACTS OF TERRORISM CX 00 01 04-13 COMMERCIAL EXCESS LIABILITY COVERAGE FORM XLS-2327 01-19 MULTI-UNIT HABITATIONAL CONVERSION EXCLUSION XLS-2383 04-13 LIMITS ENDORSEMENT
UTS-331s-CA 03-05 REGISTERED DOMESTIC PARTNER-CALIFORNIA CX 21 03 04-13 TOTAL POLLUTION EXCLUSION WITH A HOSTILE FIRE EXCEPTION CX 21 13 04-13 EXCLUSION - FUNGI OR BACTERIA
CX 21 47 12-20 PUBLIC OR LIVERY PASSENGER CONVEYANCE AND ON-DEMAND
DELIVERY SERVICES EXCLUSION
UTS-641 06-23 CONTINUING OR ONGOING DAMAGE EXCLUSION
UTS-BR-656 11-23 EXCLUSION - CYBER RISK
XLS-0381 05-15 CROSS LIABILITY EXCLUSION (Named Insured) XLS-0405 11-08 DESIGNATED OPERATIONS EXCLUSION
XLS-0795 11-08 KNOWN INJURY OR DAMAGE EXCLUSION
XLS-1160 11-08 PROFESSIONAL LIABILITY EXCLUSION
XLS-2519 08-17 SPECIFIED PROJECT EXCLUSION
XLS-2520 10-16 CONSOLIDATED (WRAP-UP) INSURANCE PROGRAM EXCLUSION XLS-2661 06-22 PFC/PFAS EXCLUSION
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 344 of 357
UTS-SP-2L 12-95 Page 2 of 2
SCHEDULE OF FORMS AND ENDORSEMENTS
Policy No.Effective Date:
12:01 A.M., Standard Time
Named Insured Agent No.FIRESTONE BUILDERS, INC.
XLS2007199 06/01/2025
04747
XLS-BR-2573 11-19 RESIDENTIAL PROJECT - LIMITED EXCLUSION XLS-BR-2622 09-22 COMMON EXCLUSIONS AND CONDITIONS
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 345 of 357
SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE
THE EXPIRATION DATE THEREOF, NOTICE WILL BE DELIVERED IN ACCORDANCE WITH THE POLICY PROVISIONS.
INSURER(S) AFFORDING COVERAGE
INSURER F :
INSURER E :
INSURER D :
INSURER C :
INSURER B :
INSURER A :
NAIC #
NAME:
CONTACT
A/C, No):
FAX
E-MAIL
ADDRESS:
PRODUCER
A/C, No, Ext):
PHONE
INSURED
REVISION NUMBER:CERTIFICATE NUMBER:COVERAGES
IMPORTANT: If the certificate holder is an ADDITIONAL INSURED, the policy(ies) must have ADDITIONAL INSURED provisions or be endorsed.
If SUBROGATION IS WAIVED, subject to the terms and conditions of the policy, certain policies may require an endorsement. A statement on this certificate does not confer rights to the certificate holder in lieu of such endorsement(s).
THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS NO RIGHTS UPON THE CERTIFICATE HOLDER. THIS
CERTIFICATE DOES NOT AFFIRMATIVELY OR NEGATIVELY AMEND, EXTEND OR ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW. THIS CERTIFICATE OF INSURANCE DOES NOT CONSTITUTE A CONTRACT BETWEEN THE ISSUING INSURER(S), AUTHORIZED REPRESENTATIVE OR PRODUCER, AND THE CERTIFICATE HOLDER.
OTHER:
Per accident)
Ea accident)
N / A
SUBR
WVD
ADDL
INSD
THIS IS TO CERTIFY THAT THE POLICIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED. NOTWITHSTANDING ANY REQUIREMENT, TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS
CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POLICIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS, EXCLUSIONS AND CONDITIONS OF SUCH POLICIES. LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS.
PROPERTY DAMAGE
BODILY INJURY (Per accident)
BODILY INJURY (Per person)
COMBINED SINGLE LIMIT
AUTOS ONLY
AUTOSAUTOSONLY
NON-OWNED
SCHEDULEDOWNED
ANY AUTO
AUTOMOBILE LIABILITY
Y / N
WORKERS COMPENSATION
AND EMPLOYERS' LIABILITY
OFFICER/MEMBER EXCLUDED?
Mandatory in NH)
DESCRIPTION OF OPERATIONS below
If yes, describe under
ANY PROPRIETOR/PARTNER/EXECUTIVE
E.L. DISEASE - POLICY LIMIT
E.L. DISEASE - EA EMPLOYEE
E.L. EACH ACCIDENT
ER
OTH-
STATUTE
PER
LIMITS(MM/DD/YYYY)
POLICY EXP
MM/DD/YYYY)
POLICY EFF
POLICYNUMBERTYPEOFINSURANCELTR
INSR
DESCRIPTION OF OPERATIONS / LOCATIONS / VEHICLES (ACORD 101, Additional Remarks Schedule, may be attached if more space is required)
EXCESS LIAB
UMBRELLA LIAB $EACH OCCURRENCE
AGGREGATE
OCCUR
CLAIMS-MADE
DED RETENTION $
PRODUCTS - COMP/OP AGG
GENERAL AGGREGATE
PERSONAL & ADV INJURY
MED EXP (Any one person)
EACH OCCURRENCE
DAMAGE TO RENTED
PREMISES (Ea occurrence)
COMMERCIAL GENERAL LIABILITY
CLAIMS-MADE OCCUR
GEN'L AGGREGATE LIMIT APPLIES PER:
POLICY
PRO-
JECT LOC
CERTIFICATE OF LIABILITY INSURANCE
DATE (MM/DD/YYYY)
CANCELLATION
AUTHORIZED REPRESENTATIVE
ACORD 25 (2016/03)
1988-2015 ACORD CORPORATION. All rights reserved.
CERTIFICATE HOLDER
The ACORD name and logo are registered marks of ACORD
HIRED
AUTOS ONLY
2/5/2026
Kirk Miller Insurance Agency, Inc.
10636 Scripps Summit Court #110
San Diego CA 92131
Jodi Hollow
858) 240-2593
[email protected]
Firestone Builders, Inc
751 Rancheros Drive #9
San Marcos CA 92069-3043
SCOTTSDALE INS CO 41297
TRUCK INS EXCHANGE 21652
STATE COMPENSATION INS FUND 35076
25.26 Master
A BI/PD DED @ $5K Per Occ Y Y BCS2002688 06/01/2025 06/01/2026 1,000,000
100,000
Excluded
1,000,000
2,000,000
2,000,000
B Y Y 604742329 06/01/2025 06/01/2026
2,000,000
A
0 XLS2007199 06/01/2025 06/01/2026
5,000,000
5,000,000
C Y 9263541-2024 11/14/2025 11/14/2026
1,000,000
1,000,000
1,000,000
City of Vista and Buena Sanitation District are named as additional insured. Excess policy is primary and non-contributory to the City?s insurances, per the attached endorsement.
City of Vista and
Buena Sanitation District
200 Civic Center Drive
Vista CA 92084
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 346 of 357
POLICY NUMBER: CA00005668201 COMMERCIAL GENERAL LIABILITY CG 20 10 12 19
THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY.
CG 20 10 12 19 © Insurance Services Office, Inc., 2018 Page 1 of 2 ADDITIONAL INSURED – OWNERS, LESSEES OR
CONTRACTORS – SCHEDULED PERSON OR
ORGANIZATION
This endorsement modifies insurance provided under the following:
COMMERCIAL GENERAL LIABILITY COVERAGE PART
SCHEDULE
Name Of Additional Insured Person(s)
Or Organization(s) Location(s) Of Covered Operations
Information required to complete this Schedule, if not shown above, will be shown in the Declarations.
A.Section II – Who Is An Insured is amended to
include as an additional insured the person(s) or
organization(s) shown in the Schedule, but only
with respect to liability for "bodily injury", "property damage" or "personal and advertising injury"
caused, in whole or in part, by:
1.Your acts or omissions; or
2.The acts or omissions of those acting on your
behalf;
in the performance of your ongoing operations for
the additional insured(s) at the location(s)
designated above.
However:
1.The insurance afforded to such additional
insured only applies to the extent permitted by
law; and
2. If coverage provided to the additional insured is
required by a contract or agreement, the
insurance afforded to such additional insured
will not be broader than that which you are
required by the contract or agreement to
provide for such additional insured.
B.With respect to the insurance afforded to these
additional insureds, the following additional
exclusions apply:
This insurance does not apply to "bodily injury" or
property damage" occurring after:
1.All work, including materials, parts or
equipment furnished in connection with such
work, on the project (other than service,
maintenance or repairs) to be performed by or
on behalf of the additional insured(s) at the
location of the covered operations has been
completed; or
2.That portion of "your work" out of which the
injury or damage arises has been put to its
intended use by any person or organization
other than another contractor or subcontractor
engaged in performing operations for a
principal as a part of the same project.
Any person or organization that is an owner, lessee or manager of real property or personal property on which you are
performing ongoing operations, or a contractor on whose behalf you are performing ongoing operations, but only if coverage as an additional insured is required by a written contract or written agreement that is an “insured contract”, and provided the “bodily injury” or “property damage” first occurs, or the “personal and advertising injury” offense is first committed, subsequent to the execution of the contract or agreement.
All locations at which the Named Insured is performing
ongoing operations.
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 347 of 357
C.With respect to the insurance afforded to these
additional insureds, the following is added to
Section III – Limits Of Insurance:
If coverage provided to the additional insured is
required by a contract or agreement, the most we
will pay on behalf of the additional insured is the
amount of insurance:
1.Required by the contract or agreement; or
2.Available under the applicable limits of
insurance;
whichever is less.
This endorsement shall not increase the
applicable limits of insurance.
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 348 of 357
POLICY NUMBER: CA00005668201 COMMERCIAL GENERAL LIABILITY CG 20 37 12-19
THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY.
CG 20 37 12-19 © Insurance Services Office Inc. 2018 Page 1 of 1
ADDITIONAL INSURED - OWNERS, LESSEES OR
CONTRACTORS - COMPLETED OPERATIONS
This endorsement modifies insurance provided under the following:
COMMERCIAL GENERAL LIABILITY COVERAGE PART
PRODUCTS/COMPLETED OPERATIONS LIABILITY COVERAGE PART
SCHEDULE
Name Of Additional Insured Person(s)
Or Organization(s)Location And Description Of Completed Operations Any person or organization that is an owner, lessee or
manager of real property or personal property for
whom you work or have worked, or a contractor on
whose behalf you work or have worked, but only if
coverage as an additional insured extending to "bodily
injury" or "property damage" included in the "products- completed operations hazard" is required by a written
contract or written agreement that is an "insured
contract" and provided that the "bodily injury" or
property damage" first occurs subsequent to the
execution of the contract or agreement.
All locations except locations where "your work" is or
was related to a job or project involving single-family dwellings, multi-family dwellings (other than rental
apartments in an apartment building: (a) originally
constructed and at all times used for such purpose, or
b) converted from a commercial building),
condominiums, townhomes, townhouses, timeshare
units, fractional-ownership units, cooperatives and/or
any other structure or space used or intended to be
used as a residence.
A. Section II - Who Is An Insured is amended to
include as an additional insured the person(s) or
organization(s) shown in the Schedule, but only
with respect to liability for "bodily injury" or
property damage" caused, in whole or in part, by
your work" at the location designated and
described in the Schedule of this endorsement
performed for that additional insured and included
in the "products-completed operations hazard".
However:
1.The insurance afforded to such additional
insured only applies to the extent permitted by
law; and
2.If coverage provided to the additional insured is
required by a contract or agreement, the
insurance afforded to such additional insured
will not be broader than that which you are
required by the contract or agreement to
provide for such additional insured.
B.With respect to the insurance afforded to these
additional insureds, the following is added to
Section III - Limits Of Insurance:
If coverage provided to the additional insured is
required by a contract or agreement, the most we
will pay on behalf of the additional insured is the
amount of insurance:
1.Required by the contract or agreement; or
2.Available under the applicable limits of
Insurance;
whichever is less.
This endorsement shall not increase
the applicable limits of Insurance.
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 349 of 357
POLICY NUMBER:COMMERCIAL GENERAL LIABILITY
CG 24 04 12 19
THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY.
CG 24 04 12 19 © Insurance Services Office, Inc., 2018 Page 1 of 1
WAIVER OF TRANSFER OF RIGHTS OF RECOVERY
AGAINST OTHERS TO US (WAIVER OF SUBROGATION)
This endorsement modifies insurance provided under the following:
COMMERCIAL GENERAL LIABILITY COVERAGE PART
ELECTRONIC DATA LIABILITY COVERAGE PART
LIQUOR LIABILITY COVERAGE PART
POLLUTION LIABILITY COVERAGE PART DESIGNATED SITES
POLLUTION LIABILITY LIMITED COVERAGE PART DESIGNATED SITES
PRODUCTS/COMPLETED OPERATIONS LIABILITY COVERAGE PART
RAILROAD PROTECTIVE LIABILITY COVERAGE PART
UNDERGROUND STORAGE TANK POLICY DESIGNATED TANKS
SCHEDULE
Name Of Person(s) Or Organization(s):
Information required to complete this Schedule, if not shown above, will be shown in the Declarations.
The following is added to Paragraph 8. Transfer Of
Rights Of Recovery Against Others To Us of
Section IV – Conditions:
We waive any right of recovery against the person(s)
or organization(s) shown in the Schedule above
because of payments we make under this Coverage
Part. Such waiver by us applies only to the extent that the insured has waived its right of recovery against
such person(s) or organization(s) prior to loss. This
endorsement applies only to the person(s) or
organization(s) shown in the Schedule above.
MWZY 316684 23 Messer Industries USA, Inc. 03/01/23 - 03/01/24 Any person or organization as required in a written contract or agreement BCS2002688
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 350 of 357
THIS ENDORSEMENT CHANGES THE POLICY.PLEASE READ IT CAREFULLY.
J7120
1st Edition
BUSINESS AUTO EXTENSIONS
This endorsement modifies insurance provided under the following:
BUSINESS AUTO COVERAGE FORM
With respect to coverage provided by this endorsement,the provisions of the Coverage Form apply unless modified by this endorsement.
Section II -Liability Coverage is amended as follows:A.
1.The following is added to Paragraph A.1.Who Is An Insured:
Blanket Additional Insured
Each person or organization with whom you agree,by virtue of a written contract or agreement, to provide insurance is an "insured",but only with respect to their legal liability for actsoromissionsofapersonforwhomLiabilityCoverageisaffordedunderthispolicy:
1)Provided that the contract or agreement is signed and executed by you prior to the "bodily injury"or "property damage"loss;and
2)The contract or agreement is in effect during the policy period.
Section IV -Business Auto Conditions is amended as follows:B.
1.The following is added to Paragraph A.5.Transfer Of Rights Of Recovery Against Other To Us:
Blanket Waiver Of Subrogation
We waive our right of recovery that we may have against a person or organization,but only to the extent that this is required of you by a written contract or agreement that is signed andexecutedpriortoany"accident"or "loss".This waiver applies only to the person or organization designated in such contract or agreement.
2.The following is added to Paragraph B.5.Other Insurance:
Primary And Noncontributory
This insurance will be primary and will not seek contribution from any other insurance available to an additional insured under your policy provided that:
1)The additional insured is a Named Insured under such other insurance; 2)You have agreed in writing in a contract or agreement that this insurance would be primary and would not seek contribution from any other insurance available to theadditionalinsured; 3)This contract or agreement is signed and executed by you prior to when the "bodily injury"or property damage"occurs;and
4)This written contract or agreement is in effect during the policy period.
This endorsement is part of your policy.It supersedes and controls anything to the contrary.It is otherwise subject to all the terms of the policy.
93-7120 1ST EDITION 9-15 Includes copyrighted material of Insurance Services Office, Inc., with its permission.J7120101 PAGE 1 OF 1 POLICY NUMBER: 604742329
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 351 of 357
POLICY NUMBER:
COMMERCIAL AUTOCA 20 48 02 99THIS ENDORSEMENT
CHANGES THE POLICY. PLEASE READ IT CAREFULLY.CA
20 48 02 99Copyright,
Insurance Services Office,
Inc., 1998 Page 1
of 1oo DESIGNATED
INSUREDThis endorsement modifies insurance provided under the following:BUSINESS AUTO COVERAGE FORM GARAGE COVERAGE FORM MOTOR
CARRIER COVERAGE FORM TRUCKERS
COVERAGE FORM With respect to coverage provided by this endorsement, the provisions of the Coverage Form apply unless modified by this endorsement.This endorsement identifies person(s) or organization(s) who are "insureds" under the Who Is An Insured Provi-sion of the Coverage Form. This endorsement does not alter coverage provided in the
Coverage Form.This endorsement
changes the
policy effective
on the inception date of the policy unless another date is indi-cated below.Endorsement Effective:Countersigned By:Named Insured:Authorized Representative)
SCHEDULEName of Person(s) or Organization(s):(If no entry appears above, information required to complete this endorsement will be shown in the Declarations as applicable to the endorsement.)Each person or organization shown in the Schedule is an "insured"
for Liability Coverage,
but only to
the extent that person or organization qualifies
as
an "insured" under the Who Is An Insured
11/10/2026 C6 352 of 357
POLICY NUMBER:
COMMERCIAL AUTOCA 20 48 02 99THIS ENDORSEMENT
CHANGES THE POLICY. PLEASE READ IT CAREFULLY.CA
20 48 02 99Copyright,
Insurance Services Office,
Inc., 1998 Page 1
of 1oo DESIGNATED
INSUREDThis endorsement modifies insurance provided under the following:BUSINESS AUTO COVERAGE FORM GARAGE COVERAGE FORM MOTOR
CARRIER COVERAGE FORM TRUCKERS
COVERAGE FORM With respect to coverage provided by this endorsement, the provisions of the Coverage Form apply unless modified by this endorsement.This endorsement identifies person(s) or organization(s) who are "insureds" under the Who Is An Insured Provi-sion of the Coverage Form. This endorsement does not alter coverage provided in the
Coverage Form.This endorsement
changes the
policy effective
on the inception date of the policy unless another date is indi-cated below.Endorsement Effective:Countersigned By:Named Insured:Authorized Representative)
SCHEDULEName of Person(s) or Organization(s):(If no entry appears above, information required to complete this endorsement will be shown in the Declarations as applicable to the endorsement.)Each person or organization shown in the Schedule is an "insured"
for Liability Coverage,
but only to
the extent that person or organization qualifies
as
an "insured" under the Who Is An Insured
11/10/2026 C6 353 of 357
XLS-D-1 01-21
COMMERCIAL EXCESS LIABILITY POLICY
18700 North Hayden Road · Scottsdale, Arizona 85255
1-800-423-7675
A STOCK COMPANY
ITEM 1. NAMED INSURED(S) AND MAILING ADDRESS AGENT NAME AND ADDRESS ITEM 2. POLICY PERIOD From:
12:01 A.M. Standard Time at your mailing address shown above.
DECLARATIONS
Policy Number
THIS COMMERCIAL EXCESS LIABILITY DECLARATIONS WITH THE COVERAGE FORM AND ENDORSEMENTS, IF ANY, COMPLETE THE ABOVE-NUMBERED POLICY.
Renewal of Number
To: 06/01/2026
Rate: _____________________________Per:
Policy Minimum Premium ................................................................................ $ Audit Period: Annually Other:
ITEM 7.ENDORSEMENTS ATTACHED TO THE POLICY AT INCEPTION:
See Schedule of Forms and Endorsements
New
CRC INSURANCE SERVICES
50 CALIFORNIA ST STE 2000
SAN FRANCISCO CA 94111-4703
06/01/2025
5,000,000
5,000,000
32,223
X
X
XLS2007199
In return for the payment of the premium, and subject to all the terms of this policy, we agree to provide you with the insurance as stated in this policy.
ITEM 3. THE NAMED INSURED IS: q Individual q Partnership q Corporation q Joint Venture q Other ITEM 4.LIMIT(S) OF INSURANCE:
A.Each Occurrence ............................................................................................ $ ___________________________ B. Aggregate ....................................................................................................... $ __________________________ ITEM 5.SCHEDULE OF CONTROLLING UNDERLYING INSURANCE:
See Schedule of Controlling Underlying Insurance
ITEM 6.PREMIUM COMPUTATION:
q Flat Premium:$ __________________________
q Subject to Adjustment:
Estimated Deposit Premium ..............................................................................$ __________________________ Estimated Exposure Base: ___________________________________________ FIRESTONE BUILDERS, INC.
751 RANCHEROS DR STE 9
SAN MARCOS CA 92069-3043
Agent No.04747 Program No.
Summary ofChargesSummaryofChargesSummaryofChargesSummaryofCharges Premium $32,223.00Premium $32,223.00Premium $32,223.00Premium $32,223.00 CRC Broker Fee $1,000.00CRCBrokerFee $1,000.00CRCBrokerFee $1,000.00CRCBrokerFee $1,000.00 CA Surplus Lines Tax $966.69CASurplusLinesTax $966.69CASurplusLinesTax $966.69CASurplusLinesTax $966.69 CA Stamping Office Fee $58.00CAStampingOfficeFee $58.00CAStampingOfficeFee $58.00CAStampingOfficeFee $58.00 Total $34,247.69Total $34,247.69Total $34,247.69Total $34,247.69 Zip Code92069ZipCode92069ZipCode92069ZipCode92069
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 354 of 357
UTS-SP-2L 12-95 Page 1 of 2
SCHEDULE OF FORMS AND ENDORSEMENTS
Policy No.Effective Date:
12:01 A.M., Standard Time
Named Insured Agent No.FIRESTONE BUILDERS, INC.
XLS2007199 06/01/2025
04747
IL N 018 01-22 CALIFORNIA FRAUD STATEMENT
NOTS0623CA 01-20 IMPORTANT NOTICE TO CALIFORNIA INSURED (D-2) NOTX0146CW 07-21 NOTICE TO POLICYHOLDERS RESTRICTIONS OF COVERAGE NOTX0178CW 03-16 CLAIM REPORTING INFORMATION
UTS-COVPG 03-21 COVER PAGE
XLS-D-1 01-21 COMMERCIAL EXCESS LIABILITY POLICY DECLARATIONS UTS-SP-2L 12-95 SCHEDULE OF FORMS AND ENDORSEMENTS
UTS-119g 06-14 MINIMUM EARNED CANCELLATION PREMIUM
UTS-74g 08-95 PUNITIVE OR EXEMPLARY DAMAGE EXCLUSION
UTS-9g 06-22 SERVICE OF SUIT CLAUSE
UTS-BR-606 12-22 LIMITATION OF COVERAGE-TWO OR MORE COVERAGE FORMS OR
POLICIES ISSUED BY US
XLS-SP-2 11-08 COMMERCIAL EXCESS LIABILITY SUPPLEMENTARY SCHEDULE OF
CONTROLLING UNDERLYING INSURANCE
CX 21 33 01-15 EXCLUSION OF CERTIFIED ACTS OF TERRORISM CX 00 01 04-13 COMMERCIAL EXCESS LIABILITY COVERAGE FORM XLS-2327 01-19 MULTI-UNIT HABITATIONAL CONVERSION EXCLUSION XLS-2383 04-13 LIMITS ENDORSEMENT
UTS-331s-CA 03-05 REGISTERED DOMESTIC PARTNER-CALIFORNIA CX 21 03 04-13 TOTAL POLLUTION EXCLUSION WITH A HOSTILE FIRE EXCEPTION CX 21 13 04-13 EXCLUSION - FUNGI OR BACTERIA
CX 21 47 12-20 PUBLIC OR LIVERY PASSENGER CONVEYANCE AND ON-DEMAND
DELIVERY SERVICES EXCLUSION
UTS-641 06-23 CONTINUING OR ONGOING DAMAGE EXCLUSION
UTS-BR-656 11-23 EXCLUSION - CYBER RISK
XLS-0381 05-15 CROSS LIABILITY EXCLUSION (Named Insured) XLS-0405 11-08 DESIGNATED OPERATIONS EXCLUSION
XLS-0795 11-08 KNOWN INJURY OR DAMAGE EXCLUSION
XLS-1160 11-08 PROFESSIONAL LIABILITY EXCLUSION
XLS-2519 08-17 SPECIFIED PROJECT EXCLUSION
XLS-2520 10-16 CONSOLIDATED (WRAP-UP) INSURANCE PROGRAM EXCLUSION XLS-2661 06-22 PFC/PFAS EXCLUSION
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 355 of 357
UTS-SP-2L 12-95 Page 2 of 2
SCHEDULE OF FORMS AND ENDORSEMENTS
Policy No.Effective Date:
12:01 A.M., Standard Time
Named Insured Agent No.FIRESTONE BUILDERS, INC.
XLS2007199 06/01/2025
04747
XLS-BR-2573 11-19 RESIDENTIAL PROJECT - LIMITED EXCLUSION XLS-BR-2622 09-22 COMMON EXCLUSIONS AND CONDITIONS
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 356 of 357
Underwritten by Scottsdale Insurance Company ENDORSEMENT NO.
ATTACHED TO AND
FORMING A PART OF
POLICY NUMBER
ENDORSEMENT EFFECTIVE DATE
12:01 A.M. STANDARD TIME)
NAMED INSURED AGENT NO.
XLS-BR-2749 (07-24) Page 1 of 1
THIS ENDORSEMENT CHANGES THE POLICY. PLEASE READ IT CAREFULLY.
OTHER INSURANCE CONDITION DELETED
This endorsement modifies insurance provided under the following:
COMMERCIAL EXCESS LIABILITY COVERAGE PART
Under SECTION III—CONDITIONS, paragraph 8. Other Insurance is deleted in its entirety.
All other terms and conditions of this policy remain unchanged.
AUTHORIZED REPRESENTATIVE DATE
ENDORSEMENT
NO.
ATTACHED TO AND
FORMING A PART OF
POLICY NUMBER
ENDORSEMENT EFFECTIVE DATE
12:01 A.M. STANDARD TIME)
NAMED INSURED AGENT NO.
Underwritten by Scottsdale Insurance Company
XLS2007199 01/27/2026 FIRESTONE BUILDERS, INC.04747
Docusign Envelope ID: 59FBE450-69EC-4BBB-9001-50D52F1787A4 11/10/2026 C6 357 of 357