PATH OF EMERGENCY EGRESS TRAVEL
R-2.1 OCCUPANCY MAXIMUM: 250'
COMMON PATH OF EMERGENCY EGRESS TRAVEL
R-2.1 OCCUPANCY MAXIMUM: 75'
EGRESS EXIT DIRECTION
2A-10B:C CFC 906 FIRE EXTINGUISHER IN CABINET
75' MAX. TRAVEL DISTANCE
4A-20B:C FIRE EXTINGUISHER ON BRACKET
OCCUPANCY SIGN PER 1004.9
TACTILE EXIT SIGN MARKED "EXIT" PER 1013.4,
DETAILS ON SHEET A847
TACTILE EXIT SIGN MARKED "TO EXIT" PER 1013.4,
DETAILS ON SHEET A847
OCCUPANT LOAD AT EXIT
EXIT SIGN W/ INTEGRATED DIRECTIONAL ARROW
WHERE OCCURS AT ALL EXITS, EVERY 100' IN
CORRIDORS, AND IN SPACES WHERE 2 MORE ARE
REQUIRED PER SECTION 1013. SEE ELECTRICAL
DRAWINGS. (W/ POCHE INDICATING "EXIT" TEXT
SIDE OF SIGN.) SIGNS SHOWN IN CORRIDORS ARE
CEILING HUNG. SIGNS SHOWN ON WALL ARE
WALL HUNG.
PANIC DOOR HARDWARE
47 FEC
FE
OP
TE
TTE
MIN EGRESS PATH WIDTH
44" MIN AT CORRIDORS (0.3" PER OCC)
36" MIN AT OTHER COMPONENTS (0.2" PER OCC)
P
1-HOUR FIRE BARRIER
ADDITIONAL PROTECTION FEATURES REQUIRED
1-HOUR FIRE PARTITION
ADDITIONAL PROTECTION FEATURES REQUIRED
NON-RATED WALL
NO ADDITIONAL PROTECTION FEATURES
NON-RATED SMOKE PARTITION
A. SEE SPECIFIC WALL ASSEMBLY TYPES ON FLOOR
PLANS AND A801 FOR DETAILS
B. AT WALL TYPES DESIGNATED BELOW WITH NOTE:
“ADDITIONAL PROTECTION FEATURES REQUIRED”,
SEE DOOR AND WINDOW SCHEDULES FOR
RATINGS, MECHANICAL DRAWINGS, PENETRATION
DETAILS, JOINT DETAILS, AND FOR CONTINUITY
REQUIREMENTS, SEE ASSOCIATED VERTICAL
SECTIONS AND DETAILS (AND HORIZONTAL
ASSEMBLIES WHERE REQUIRED.)
C. AT WALL TYPES DESIGNATED BELOW, IN
ACCESSIBLE CONCEALED SPACES PER CBC 2022,
SECTION 703.5, PROVIDE PERMANENT SIGNAGE
NOTING "FIRE AND OR SMOKE BARRIER -
PROTECT ALL OPENINGS".
132 SF
NC 2
OLF 200 = 1 OCC
132 SF
NC 3
OLF 200 = 1 OCC
132 SF
NC 4
OLF 200 = 1 OCC
132 SF
NC 5
OLF 200 = 1 OCC
132 SF
NC 6
OLF 200 = 1 OCC
132 SF
NC 7
OLF 200 = 1 OCC
132 SF
NC 8
OLF 200 = 1 OCC
132 SF
NC 9
OLF 200 = 1 OCC
NC 10
137 SF
OLF 200 = 1 OCC
134 SF
NC 1
OLF 200 = 1 OCC
602 SF
HALLWAY
OLF 200 = 4 OCC
1970 SF
HALLWAY
OLF 200 = 10 OCC
149 SF
STORAGE
OLF 300 = 1 OCC
125 SF
OFFICE
OLF 150 = 1 OCC
499 SF
LAUNDRY
OLF 200 = 3 OCC
134 SF
STORAGE
OLF 300 = 1 OCC
123 SF
LINEN STORAGE
OLF 300 = 1 OCC
695 SF
MEN RR
OLF 200 = 4 OCC
67 SF
KITCHEN RR
OLF 200 = 1 OCC
65 SF
OFFICE
OLF 150 = 1 OCC
979 SF
COMM KITCHEN
OLF 200 = 5 OCC
101 SF
STORAGE
OLF 300 = 1 OCC
116 SF
FIRE
OLF 300 = 1 OCC
121 SF
ELECTRICAL
OLF 300 = 1 OCC
93 SF
STAFF RR
OLF 150 = 1 OCC
72 SF
DATA
OLF 300 = 1 OCC
230 SF
ADMIN OFFICE
OLF 150 = 2 OCC
242 SF
CASE MGMT
OLF 150 = 2 OCC
259 SF
CASE MGMT
OLF 150 = 2 OCC 143 SF
PEST CONTROL
OLF 300 = 1 OCC
INTAKE
165 SF
OLF 150 = 2 OCC
629 SF
COUNSELING
OLF 15 = 42 OCC
252 SF
HALLWAY
OLF 200 = 2 OCC
74 SF
MEDICATION
OLF 300 = 1 OCC
118 SF
OFFICE
OLF 150 = 1 OCC
118 SF
OFFICE
OLF 150 = 1 OCC
95 SF
UTILITY
OLF 300 = 1 OCC
93 SF
MAINT
OLF 300 = 1 OCC
147 SF
ADMIN OFFICE
OLF 150 = 1 OCC
116 SF
LAUNDRY
OLF 200 = 1 OCC
466 SF
WOMEN RR
OLF 200 = 3 OCC
189 SF
MEN RR NC
OLF 200 = 1 OCC
197 SF
WOMEN RR NC
OLF 200 = 1 OCC
75 SF
MEN RR NC
OLF 200 = 1 OCC
78 SF
WOMEN RR NC
OLF 200 = 1 OCC
460 SF
DAY ROOM
OLF 15 = 31 OCC
165 SF
NC 11
OLF 200 = 1 OCC
169 SF
NC 12
OLF 200 = 1 OCC
158 SF
NC 13
OLF 200 = 1 OCC
172 SF
NC 14
OLF 200 = 1 OCC
ROOF OVERHANG ABOVE
296 SF
FRIDGE
OLF 300 = 1 OCC
EXIT DISCHARGE
TO PUBLIC WAY
EXIT DISCHARGE
EXIT DISCHARGE
EXIT
EXIT
EXIT
COMMON PATH = 45' - 6"
COMMON PATH = 37' - 6"
PATH OF TRAVEL = 108' - 10"
PATH OF TRAVEL = 101' - 10" PATH OF TRAVEL = 76' - 1"
PATH OF TRAVEL = 93' - 0"
COMMON PATH = 20' - 10"
EXIT
EXIT
25 25
25 25
5 EXIT
FEC
FEC
FEC
FEC FEC
FEC
FEC
d/3
= 55' - 11"
155' - 8"
5' - 0"
2' - 4"
11' - 5"
8' - 0"
14' - 6"
1' - 10"
OVERHANG ABOVE
8' - 7"
P
P
P
P
P
P
PATH OF TRAVEL = 78' - 0"
EXIT DISTANCE
112' - 6"
P
EXIT DISCHARGE
EXITEXIT
EXIT
25 POTENTIAL EXISTING
ROOF DEMO TO BE
COORDINATED WITH
FIRE MARSHAL
CLR
44"
SERVICE ONLY GATE
5' - 0" 3' - 0" IMAGINARY LINE LINE PER 705.5
9' - 6"
A K
3'-0" DISTANCE TO
IMAGINARY LOT LINE (15%
OPENINGS ALLOWED)
9'-6" DISTANCE TO
IMAGINARY LOT LINE (25%
OPENINGS ALLOWED)
CANOPY COLUMN -TYP
NON-COMPUSTIBLE
12' - 8" 1' - 10" CANOPY -TYP
2'-4" DISTANCE TO
ADJACENT BUILDING ROOF
(0% OPENINGS ALLOWED)
ALLOWABLE OPENING AREA PER TABLE 705.8
527.7 SF
OPENINGS: 55.0 SF
56.9 SF ÷ 527.7 SF = 10.8%
185.1 SF 580.0 SF
OPENINGS 60.9 SF
60.9 ÷ 580.0 = 10.5%
8'-7" DISTANCE TO
ADJACENT BUILDING ROOF
(25% OPENINGS ALLOWED)
26.5 SF
T.O. FLAT ROOF
A. THIS CODE ANALYSIS PLAN IS FOR REFERENCE
ONLY. SEE ALL OTHER PLAN SHEETS FOR
CONTRACT DOCUMENT INFORMATION. THIS CODE
ANALYSIS IDENTIFIES SOME SPECIFIC BUILDING
CODE REQUIREMENTS BUT IS NOT INTENDED TO
LIST ALL BUILDING CODE REQUIREMENTS.
B. SEE G-009 SHEET FOR CODE SUMMARY AND AREA
CALCULATIONS.
C. SEE G-010, A-847, A-852 AND OTHER PLAN AND
DETAIL SHEETS FOR ACCESSIBILITY
CONFORMANCE.
D. SEE SITE PLAN FOR EXIT DISCHARGE, PROPERTY
LINE, PUBLIC WAY LOCATIONS, AND COURTYARD
LAYOUT (WHERE OCCURS).
E. EGRESS LIGHTING SHALL BE PROVIDED IN ALL
CORRIDORS, LOBBIES AND AT ALL INTERIOR AND
EXTERIOR DESIGNATED EGRESS PATHS.
LIGHTING SHALL BE CONTINUOUS TO EXTERIOR
LANDING OF EGRESS DOORS AND PROVIDED A
MINIMUM OF
1 FOOTCANDLE OF LIGHTING ON 90-MIN BATTERY
BACKUP POWER. SEE ELECTRICAL DRAWINGS
FOR ADDITIONAL INFORMATION.
W7 W7 W7 W7
EXISTING WINDOWS
TO BE DEMOLISHED
X103 X102
EXISTING WINDOWS
TO BE DEMOLISHED
5'-0" DISTANCE TO
IMAGINARY LOT LINE
(25% OPENINGS ALLOWED)
2'-4" DISTANCE FROM
BUILDING OVERHANG
TO NEW BUILDING
8'-7" DISTANCE TO IMAGINARY LOT LINE
(25% OPENINGS ALLOWED)
PROPOSED NEW SINGLE HUNG
WINDOWS. WINDOWS MEET EXIT
REQUIREMENTS PER CBC 2022 - 1031.3.1
NO ADJACENT STRUCTURE
(OPENINGS ALLOWED - NO LIMIT)
940.3 SF
OPENINGS 219.0 SF
219.0 ÷ 940.3 = 23.3%
NEW DOOR NEW DOOR
FOR DISTANCES FROM
EDGE OF OVERHANG TO
PROPOSED BUILDING, SEE
FLOOR PLAN - A-201
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
2222 NE OREGON ST.
SUITE 101
PORTLAND, OR 97232
PHONE: 503.702.2575
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:5
5 A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
FIRE & LIFE
SAFETY PLANS
G-010
EN, KS, JL
AS
07/25/24
LEGEND
LEGEND - WALL TYPES
1/8" = 1'-0"G-010
1 FIRE & LIFE SAFETY PLAN
OCCUPANT LOAD
OCCUPANCY NAME AREA FUNCTION OF SPACE OLF
OCCUPANT
LOAD
B ADMIN OFFICE 230 SF BUSINESS AREAS 150 2
B ADMIN OFFICE 147 SF BUSINESS AREAS 150 1
B CASE MGMT 242 SF BUSINESS AREAS 150 2
B CASE MGMT 259 SF BUSINESS AREAS 150 2
B COMM
KITCHEN
979 SF KITCHENS,
COMMERCIAL
200 5
B DATA 72 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
B FRIDGE 296 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
B INTAKE 165 SF BUSINESS AREAS 150 2
B KITCHEN RR 67 SF KITCHENS,
COMMERCIAL
200 1
B MEDICATION 74 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
B OFFICE 125 SF BUSINESS AREAS 150 1
B OFFICE 65 SF BUSINESS AREAS 150 1
B OFFICE 118 SF BUSINESS AREAS 150 1
B OFFICE 118 SF BUSINESS AREAS 150 1
B PEST CONTROL 143 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
B STAFF RR 93 SF BUSINESS AREAS 150 1
B STORAGE 149 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
B STORAGE 101 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
26 R-2.1 COUNSELING 629 SF ASSEMBLY 15 42
R-2.1 DAY ROOM 460 SF ASSEMBLY 15 31
R-2.1 ELECTRICAL 121 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
R-2.1 FIRE 116 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
R-2.1 HALLWAY 602 SF RESIDENTIAL 200 4
R-2.1 HALLWAY 1970 SF RESIDENTIAL 200 10
R-2.1 HALLWAY 252 SF RESIDENTIAL 200 2
R-2.1 LAUNDRY 499 SF RESIDENTIAL 200 3
R-2.1 LAUNDRY 116 SF RESIDENTIAL 200 1
R-2.1 LINEN
STORAGE
123 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
R-2.1 MAINT 93 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
R-2.1 MEN RR 695 SF RESIDENTIAL 200 4
R-2.1 MEN RR NC 189 SF RESIDENTIAL 200 1
R-2.1 MEN RR NC 75 SF RESIDENTIAL 200 1
R-2.1 NC 1 134 SF RESIDENTIAL 200 1
R-2.1 NC 2 132 SF RESIDENTIAL 200 1
R-2.1 NC 3 132 SF RESIDENTIAL 200 1
R-2.1 NC 4 132 SF RESIDENTIAL 200 1
R-2.1 NC 5 132 SF RESIDENTIAL 200 1
R-2.1 NC 6 132 SF RESIDENTIAL 200 1
R-2.1 NC 7 132 SF RESIDENTIAL 200 1
R-2.1 NC 8 132 SF RESIDENTIAL 200 1
R-2.1 NC 9 132 SF RESIDENTIAL 200 1
R-2.1 NC 10 137 SF RESIDENTIAL 200 1
R-2.1 NC 11 165 SF RESIDENTIAL 200 1
R-2.1 NC 12 169 SF RESIDENTIAL 200 1
R-2.1 NC 13 158 SF RESIDENTIAL 200 1
R-2.1 NC 14 172 SF RESIDENTIAL 200 1
R-2.1 STORAGE 134 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
R-2.1 UTILITY 95 SF ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
300 1
R-2.1 WOMEN RR 466 SF RESIDENTIAL 200 3
R-2.1 WOMEN RR NC 197 SF RESIDENTIAL 200 1
R-2.1 WOMEN RR NC 78 SF RESIDENTIAL 200 1
124
1/8" = 1'-0"G-010
2 FIRE & LIFE SAFETY - WEST ELEVATION
GENERAL NOTES - FIRE/LIFE SAFETY
1/8" = 1'-0"G-010
4 FIRE & LIFE SAFETY - EAST ELEVATION EXISTING BUILDING
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:30:56 AM
C:\Users\enavarro\Documents\_RevitLocal\2321 24_0903 Shelter Expansion_R21_enavarroQT4G7.rvt 2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
CALGREEN
CHECKLIST
NON-RESIDENTIAL
G-020
EN, KS, JL
AS
09/19/24
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:30:56 AM
C:\Users\enavarro\Documents\_RevitLocal\2321 24_0903 Shelter Expansion_R21_enavarroQT4G7.rvt 2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
CALGREEN
CHECKLIST
NON-RESIDENTIAL
G-021
EN, KS, JL
AS
09/19/24
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:30:57 AM
C:\Users\enavarro\Documents\_RevitLocal\2321 24_0903 Shelter Expansion_R21_enavarroQT4G7.rvt 2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
CALGREEN
CHECKLIST
NON-RESIDENTIAL
G-022
EN, KS, JL
AS
09/19/24
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:30:57 AM
C:\Users\enavarro\Documents\_RevitLocal\2321 24_0903 Shelter Expansion_R21_enavarroQT4G7.rvt 2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
CALGREEN
CHECKLIST
NON-RESIDENTIAL
G-023
EN, KS, JL
AS
09/19/24
NO PARKING NO PARKING
LAUGENOUR AND MEIKLE
CIVIL ENGINEERING · LAND SURVEYING · PLANNING
· LM · REDUCED PLOT
TITLE SHEET
© L A U G E N O U R A N D M E I K L E © L A U G E N O U N A R
D M E I K L E
© L A U G E N O U R A N D M E I K L E © L A U G E N O U N A R
D M E I K L E
LM
C001
SHEET 1 OF 14
LAUGENOUR AND MEIKLE
CIVIL ENGINEERING · LAND SURVEYING · PLANNING
· LM · REDUCED PLOT
ABBREVIATIONS & GENERAL NOTES
C002
SHEET 2 OF 14
·
·
·
±
LAUGENOUR AND MEIKLE
CIVIL ENGINEERING · LAND SURVEYING · PLANNING
· LM · REDUCED PLOT
TOPOGRAPHIC SURVEY & DEMOLITION PLAN
C101
SHEET 3 OF 14
© L A U G E N O U R A N D M E I K L E © L A U G E N O U N A R
D M E I K L E
LM
LAUGENOUR AND MEIKLE CIVIL ENGINEERING · LAND SURVEYING · PLANNING · LM · REDUCED PLOT CIVIL SITE PLAN C201 SHEET 4 OF 12 © L A U G E N O U R A N D M E I K L E © L A U G E N O U N A R D M E I K L E LM
LAUGENOUR AND MEIKLE
CIVIL ENGINEERING · LAND SURVEYING · PLANNING
· LM · REDUCED PLOT
GRADING & DRAINAGE PLAN
C301
SHEET 5 OF 14
© L A U G E N O U R A N D M E I K L E © L A U G E N O U N A R
D M E I K L E
LM
± LAUGENOUR AND MEIKLE CIVIL ENGINEERING · LAND SURVEYING · PLANNING · LM · REDUCED PLOT UTILITIES PLAN C401 SHEET 6 OF 14 © L A U G E N O U R A N D M E I K L E © L A U G E N O U N A R D M E I K L E LM
LAUGENOUR AND MEIKLE
CIVIL ENGINEERING · LAND SURVEYING · PLANNING · LM · REDUCED PLOT
EROSION & SEDIMENTATION CONTROL PLAN
C601
SHEET 7 OF 14
© L A U
G
E
N
O U R A N D M
E I K L E © L A U G E
N
O U N A R D M
E I K L E
LM
√√√ √√ √√√ √ √ √√√ √ √√√√ √√√√√√√√
LAUGENOUR AND MEIKLE
CIVIL ENGINEERING · LAND SURVEYING · PLANNING
· LM · REDUCED PLOT
DETAILS
C701
SHEET 9 OF 14
NO
PARKING
NO
PARKING
MINIMUM
FINE $250
PARKING
ONLY
VAN
ACCESSIBLE
UNAUTHORIZED VEHICLES PARKED
IN DESIGNATED ACCESSIBLE
SPACES NOT DISPLAYING
DISTINGUISHING PLACARDS OR
SPECIAL LICENSE PLATES ISSUED
FOR PERSONS WITH DISABILITIES
WILL BE TOWED AWAY
AT THE OWNER'S EXPENSE.
TOWED VEHICLES
MAY BE RECLAIMED AT
( ADDRESS)
OR BY TELEPHONING
(TELEPHONE NUMBER)
EV CHARGING
ONLY COMPACT
LAUGENOUR AND MEIKLE
CIVIL ENGINEERING · LAND SURVEYING · PLANNING
· LM · REDUCED PLOT
DETAILS
C702
SHEET 10 OF 14
±
LAUGENOUR AND MEIKLE
CIVIL ENGINEERING · LAND SURVEYING · PLANNING
· LM · REDUCED PLOT
FIRE PLAN
C901
SHEET 12 OF 14
© L A U G E N O U R A N D M E I K L E © L A U G E N O U N A R
D M E I K L E
LM
DS
DS
DS
DS
1 A-402
A
C
1 D
E
G
H
F
2 5 12
A-301
2 A-302
1 B
113 SF
NC-1
140
115 SF
NC-2
139
115 SF
NC-3
138
115 SF
NC-4
137
115 SF
NC-5
136
115 SF
NC-6
135
115 SF
NC-7
134
115 SF
NC-8
133
115 SF
NC-9
132
4 K
104' - 8"
227 SF
CASE
MANAGEMENT
112
216 SF
CASE
MANAGEMENT
111
60 SF
DATA
110
204 SF
ADMINISTRATION
OFFICE
109
143 SF
INTAKE
102
122 SF
PEST CONTROL
103
577 SF
GROUP
COUNSELING
124
105 SF
STORAGE LINEN
115
121 SF
UTILITY /
STORAGE
117
425 SF
LAUNDRY
114
650 SF
MEN'S
BATHROOM
118
131 SF
CLIENT STORAGE
116
105 SF
OFFICE
107
81 SF
STAFF
RESTROOM
108
410 SF
WOMEN'S
BATHROOM
148
3' - 0"9' - 6"6' - 0"11' - 0"
131 SF
ADMINISTRATION
OFFICE
128
237 SF
MEN'S
BATHROOM-NC
147
238 SF
WOMEN'S
BATHROOM-NC
144
62 SF
MEDICATION
127
104 SF
COUNSELING
OFFICE 1
143
80 SF
MECHANICAL
UTILITY
145
78 SF
MAINTENANCE
ROOM
146
87 SF
LAUNDRY
129
104 SF
COUNSELING
OFFICE 2
142
6 7 8 9 10 11
12' - 6"6' - 0"31' - 6"10' - 0"15' - 0"15' - 0"12' - 0"3' - 0"10' - 0"9' - 0" 2 A-402
440 SF
DAY ROOM
141
102 SF
WAITING AREA
125
921 SF
COMMERCIAL
KITCHEN
119
100 SF
FIRE
122
100 SF
ELECTRICAL
123
25' - 0" 12' - 9"
L
144 SF
NC-11
154
144 SF
NC-12
153
142 SF
NC-13
152
142 SF
NC-14
151
3 6' - 5 1/2" 3' - 11 1/2" 10' - 5" 10' - 5" 10' - 5" 5' - 9 1/2" 4' - 7 1/2" 10' - 5" 10' - 5" 10' - 5" 10' - 5" 10' - 11" 281 SF
WAITING AREA
105
168 SF
ENTRY
101
299 SF
HALLWAY 5
106
126 SF
HALLWAY 2
126
598 SF
HALLWAY 3
130
914 SF
HALLWAY 1
113
241 SF
HALLWAY 4
149
3 A-402
2 A-401
3 A-401
A-601
2 A-601
1 A-600
4 124' - 0"
116 SF
NC-10
131
1 A-401
W
D
DDWWW/D W/D W/D W/D W/D W/D
J
A-600
1 A-600
2 103
145
102
104
107
109A
110
108
111A
122A123A
119D
119B
119A
118A
117
115A
114A
116A
148A
149E
146
143A142A
127
140
139138137136135134133132131
147A144A
128A
124B
124A
106A
130A
147B144B
101A
119C
119E
149D
X103 149C
X102
5' - 9 3/4"
4' - 11 3/4"
22.7 109B
111B
8' - 0" FOF
11' - 1 1/2"
3' - 1" 2' - 10" 8' - 6"
3' - 1" 2' - 8" 2' - 3"
14' - 6"
6.1 24' - 6 1/2"
10' - 0 1/2"
EQ EQ EQ
EQ
EQ EQ
7.6 7.6
8.21 7B
7A
7A
7B 7B 7B 7B 7B 7B 7B 7B
7A 8A
5B
10 10
10 10
10 10
10 10
10 10
10 10
10 10
10 10
10 7A
5B
5B
5B
5B
5B
5B
5B
7A
5B
7A
7A
7A
7B
5A
5B
5B
7A
5B
9 7A
7A
7A
5A
7B
7B
7B
6B
6B
5B
5B 5B
5B
5B TYP
7B
7B
7B
7B
7B
7B
8A
8A
8A
5A
5A
5A
5A
5A
5A
6B
7A
7A
5A
5A
5A
7A
7A
7A
7A
7A
5A
7A
7A
7A
7A
8A 8A
8A
143B142B
6B
5B
W1 W3 W3 W1 W3 W3 W1 W3
W3
W3
W1
W3
W3
W1
W3
W4
W4
W4
W4
W4
W4
W4
W4 W4
W1
W1
W1
W1
W1
W1
W6 W6
W6
129
W8
W3 W1 W3 W3 W1 W3 W3 W1
W1
W6
W6
W6
2 5/8"
3' - 10"
7A
7A
7A
7A
7A
7A
EXISTING ROOF
PROJECTION TO BE
DEMOLISHED PER
COORDINATION WITH
FIRE MARSHALL
149A
W5
5' - 6 1/4"
W7
W7
W7
W7
W6
87 SF
PANTRY
119E
174 SF
REFRIGERATOR
119F
97 SF
FREEZER
119G
57 SF
RESTROOM
119C
53 SF
OFFICE
119B
5B
1 A-301
1' - 6"
112
X104
X105
X106
X107
W6 W6 W6
1' - 6"
5A
5B
8.21 7.6
7.6 8.21
8.21 7.6 7.6
G1
G2
G3
A-602
1 12' - 1 7/8" 12' - 0" 13' - 5"
149B
A-302 2
HALLWAY 1
113
26.15 W6
W6 W6
5' - 8 1/2"5 1/2"
1' - 2"
W8
7' - 2"4" 5' - 3 3/4"2' - 8" 2' - 2" 2' - 0"
6' - 10"
CLR
18"
Y101
6 7/8" 2' - 5 1/4"
2' - 5 1/4"
3' - 6 7/8" 6' - 6 7/8"
2' - 5 1/4"
6' - 6 7/8" 2' - 2" 3' - 10" 4' - 7" 5' - 7" 3' - 10" 5' - 0" 4' - 11 5/8" 4' - 7 7/8" 5' - 5 7/8"
2' - 2" 1' - 4 1/8" 4' - 6 7/8" 2' - 2" 1' - 6 5/8" 2' - 2" 1' - 9 7/8" 4' - 3 7/8" 1' - 7 1/8" 3' - 2 7/8" 3' - 2 1/8" 2' - 2" 4' - 0 7/8" 2' - 11 1/2"
2' - 8" 3' - 5 1/2"
6B
6B
2' - 0 1/4"
1' - 9"
3 A-603
1 A. SITE INFORMATION IS BASED ON OWNERS
SURVEY DATED xxxxx BY xxxxx. REFER TO THE
LEGAL SURVEY (PROVIDED BY OTHERS) FOR
PROPERTY LINE DIMENSIONS AND EXACT
LOCATIONS OF EXISTING SITE ELEMENTS.
B. ALL SURVEY INFORMATION INDICATING ALL
EXISTING CONDITIONS ARE SHOWN FOR
REFERENCE ONLY.
C. SEE CIVIL DRAWINGS FOR STANDARD SITE
ACCESSIBILITY REQUIREMENTS.
D. ALL PARKING SPACE DIMENSIONS ARE TO
GARAGE SIDE OF CURB. PARKING SPACES ARE
8’-6” WIDE UNO. SCD.
E. STREET, PARKING, DRIVE CUTS, AND / OR PUBLIC
RIGHT OF WAY INFORMATION ARE SHOWN FOR
REFERENCE ONLY. SEE CIVIL DRAWINGS FOR
DETAILED INFORMATION.
F. DIMENSIONS SHOWN ON THIS PLAN ARE FOR
GENERAL LAYOUT OF THE BUILDINGS AND SITE
ELEMENTS.
G. SEE CIVIL FOR FINISH GRADES ADJACENT TO
BUILDING.
H. ENTRY DOORS TO HAVE A SLOPE OF NOT MORE
THAN 1:48 FOR A MINIMUM OF 60" IN FRONT OF
DOORS.
I. SLOPE ALL GRADES AT PLANTING AREAS,
SIDEWALKS AND PAVING AWAY FROM THE
BUILDING. IF CONFLICTS OCCUR NOTIFY THE
ARCHITECT IMMEDIATELY.
J. SLOPE OF WALKING SURFACES TO BE NO
STEEPER THAN 1:20 AND HAVE A CROSS SLOPE
OF NO STEEPER THAN 1:48.
A. SEE SPECIFIC WALL ASSEMBLY TYPES ON FLOOR
PLANS AND A801 FOR DETAILS.
B. AT OSSC WALL TYPES DESIGNATED BELOW WITH
NOTE: “ADDITIONAL PROTECTION FEATURES
REQUIRED”, SEE DOOR AND WINDOW SCHEDULES
FOR RATINGS, MECHANICAL DRAWINGS,
PENETRATION DETAILS, JOINT DETAILS, AND FOR
CONTINUITY REQUIREMENTS, SEE ASSOCIATED
VERTICAL SECTIONS AND DETAILS (AND HORIZONTAL
ASSEMBLIES WHERE REQUIRED.)
C. AT OSSC WALLS TYPES DESIGNATED BELOW, IN
ACCESSIBLE CONCEALED SPACES PER IBC 703.5,
PROVIDE PERMANENT SIGNAGE NOTING "FIRE AND OR
SMOKE BARRIER - PROTECT ALL OPENINGS".
3-HOUR FIRE BARRIER WALL & RATED
COLUMN
2-HOUR RATED WALL
ADDITIONAL PROTECTION FEATURES
REQUIRED
1-HOUR RATED WALL
ADDITIONAL PROTECTION FEATURES
REQUIRED
NON-RATED WALL
NO ADDITIONAL PROTECTION FEATURES
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:01 A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
LEVEL 01
A-201
EN, KS, JL
AS, JM, JL
10/15/24
3/16" = 1'-0"A-201
1 LEVEL 01 FLOOR PLAN
N
0 4' 8' 12'
GENERAL NOTES
KEYNOTES
7.6 DOWNSPOUT; WITH THROUGH WALL
SCUPPER AT PARAPETS; PAINTED, TYP.,
PAINT COLOR INDICATED ON ELEVATION
8.21 DOOR ACTUATOR MOUNTED AT 42" AFF
TO TOP OF OPERABLE PARTS
22.7 HOSE BIBB
26.15 ELECTRICAL METER IS LOCATED IN
ELECTRICAL ROOM 123. THE METER IS
INTEGRATED INTO THE MAIN
SWITCHBOARD (MSB), AND THE
REQUIRED CLEARANCE IS INDICATED
WITH DASHED LINES ON THE PLAN. SEE
ELECTRICAL SHEETS E-401 FOR
ENLARGED PLAN AND E-701 FOR MSB
ELEVATION.
LEGEND - WALL TYPES
UP
A
C
1 D
E
G
H
F
2 5 12
B
4 K
6 7 8 9 10 11
L
3 J
6.1 3/4"
3/4"3/4" 3/4"
3' - 0"
3/4" 3/4"
3' - 0"
3/4"
4' - 7 1/4"1' - 3 1/4" 3/4" 3' - 0 1/4" 1' - 0 3/4"3/4" 3/4"
1 3/4" 2' - 1" 6" 2' - 6" 2 3/4" 4' - 6 3/4" 4' - 8 3/4" 4' - 10 3/4" 7' - 0 1/2" 3' - 7 3/4" 2 3/4" 6"
ROUND HSS
COLUMN -TYP, SEE
STRUCTURAL
TIMBER COLUMN -TYP,
SEE STRUCTURAL
4' - 6"
6"
3/4"
4' - 6"
6' - 11 1/4"
5 3/4"
6"
4' - 6"
1' - 10"
4' - 9"
7' - 2"
1"
1' - 8"
4"
1' - 0"
1' - 8"
1"
2' - 10"
2' - 2"
1' - 7 1/2"
1' - 7"
3' - 5 3/4"
5 1/2"
4' - 6"
2' - 1"
1' - 4"
1/2"6' - 9"
6"
1' - 3" 5' - 9" 1' - 0" 9' - 0"
6" 6" 3' - 0" 7' - 4" 6' - 8" 7' - 4"
2' - 7" 11' - 0"
6 3/4" 1' - 6 3/4" 4' - 2 3/4" 3' - 8 3/4" 6 3/4" 2' - 0" 10 1/4" 10 1/2"
14' - 10 1/4"
1% MIN
1% MIN
1% MIN
1% MIN
1% MIN
1% MIN 6 3/4"
2' - 1 1/4"
6 3/4" 1 1/4"
11' - 1 1/4" 7' - 5"
1% MIN 1% MIN
1' - 3 1/2" 1' - 6 3/4"
1' - 0 1/2"
3/4" 2' - 9 1/4"
1% MIN
1% MIN
1% MIN
1% MIN
3 1/2" 2' - 6"
5' - 3 1/4" 3' - 0 3/4"
1% MIN 1% MIN
1% MIN
1% MIN
6" 6 1/4"
5' - 0 1/2"
5' - 5 3/4"
11"
5' - 2"
6' - 1 1/2"
3' - 11 1/4" 3' - 6"
1' - 11 3/4"
1% MIN 1% MIN
6 1/4" 3' - 10 1/4"
2' - 10 1/4"
1 1/4"
1% MIN
1% MIN
A. ALL DIMENSIONS ARE TO FACE OF CONCRETE,
FACE OF FOUNDATION ,OR CENTER OF COLUMN
UNO.
B. VERIFY ALL DOOR OPENINGS SIZED IN CURBS
WITH DOOR MFR.
FLOOR DRAIN / SINK, SEE PLUMBING
SLAB SLOPE
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 1:05:21 PMC:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
SLAB PLAN
A-201s
EN, KS, JL
AS
09/18/24
A-201s 3/16" = 1'-0"
1 LEVEL 01 SLAB PLAN
N
0 4' 8' 12'
GENERAL NOTES
LEGEND
DS DOWNSPOUT
OVERBUILT CRICKET
ROOF TIE-BACK ANCHOR;
SEE STRUCTURAL
ROOF OPENING
LIGHT WELL
A. COORDINATE INTERNAL ROOF DRAINS AND
PLUMBING VENTILATION STACKS WITH DESIGN
BUILD STRUCTURAL ELEMENTS AND PLUMBING
PLANS.
B. SPOT ELEVATIONS ARE TO THE TOP OF THE ROOF
SYSTEM OF THE TOP OF THE PARAPET UNO AND
ARE RELATIVE TO THE ROOF LEVEL DATUM.
C. COORDINATE MECHANICAL UNIT LOCATIONS,
SIZES AND CLEARANCE AND OTHER
REQUIREMENTS.
D. SEE A-830 FOR ROOF PENETRATION DETAILS.
E. PROVIDE NO SLOPE LESS THAN 1/4" PER 12" AT
ROOFS, OVERHANGS, CRICKETS AND VALLEYS.
F. DRAFTSTOPPING MATERIALS SHALL BE NOT LESS
THAN 1/2" GYPSUM BOARD, 3/8" WOOD
STRUCTURAL PANEL, 3/8-INCH" PARTICLEBOARD,
1" NOMINAL LUMBER, CEMENT FIBERBOARD,
BATTS OR BLANKETS OF MINERAL WOOL OR
GLASS FIBER, OR OTHER APPROVED MATERIALS
ADEQUATELY SUPPORTED. THE INTEGRITY OF
DRAFTSTOPS SHALL BE MAINTAINED.
G. DOWNSPOUTS SHALL BE 26 GAUGE, 3" x 4"
RECTANGULAR PROFILES.
1 A-402
A
C
1 D
E
G
H
F
12 1 A-301
2 5
A-301
2 A-302
1 B
4 K
6 7 8 9 10 11
2 A-402
L
3 3
A-402
2 A-401
3 A-401
1 A-401
J
6.1 SHED ROOF
4293 SF
POTENTIAL FUTURE PV LOCATION
2500 SF MAX
LOW ROOF
6675 SF
MECHANICAL EQUIPMENT LOCATION
1 1/2" / 1'-0"
VALLEY
RIDGE
VALLEY
VALLEY
VALLEY
RIDGE
VALLEY
ROOF ACCESS HATCH,
CRICKET AT HIGH SIDE
PARAPET / STEM WALL
FACE OF WALL
BELOW -TYP
A-301
3 ROOF AREA TO BE
REINFORCED TO
SUPPORT MECHANICAL
AND PLUMBING
EQUIPMENT
ROOF AREA TO BE
REINFORCED TO
SUPPORT MAU,
SEE MECHANICAL
AND STRUCTURAL
VENTILATED RAFTER SPACE PER 1202.2.1:
1029 SF /150 = 7 SF MIN FREE AREA TOTAL
PROVIDED = 3.5 SF FREE AREA AT LOW EAVE
VENTILATED RAFTER SPACE PER 1202.2.1:
1029 SF /150 = 7 SF MIN FREE AREA TOTAL
PROVIDED = 3.5 SF FREE AREA AT HIGH EAVE
2 A-830
3 A-830
3 A-822
1 A-830
4 A-830
5 A-830
AT WALL
AT PARAPET CAP
15 A-830
15 A-830
ROOF EQUIPMENT -TYP, SEE
1/4" / 1'-0"
MECHANICAL AND PLUMBING
1/4" / 1'-0"
STEM WALL 8" ABOVE
ROOF SURFACE MIN
1/4" / 1'-0"
1/4" / 1'-0"
VALLEY
VALLEY
VALLEY
7.6 7.6
7.6 7.6
ROOF AREA TO BE
REINFORCED TO
SUPPORT CONDSENER,
SEE MECHANICAL AND
FOOD SERVICE
7.6 7.6
A-302 2
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:0
3 A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
ROOF PLAN
A-202
EN, KS, JL
AS
06/26/24
KEYNOTES
7.6 DOWNSPOUT; WITH THROUGH WALL
SCUPPER AT PARAPETS; PAINTED, TYP.,
PAINT COLOR INDICATED ON ELEVATION
LEGEND
GENERAL NOTES
3/16" = 1'-0"A-202
1 ROOF PLAN
N
0 4' 8' 12'
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
1 A-402
K H G F E D C B A
HIGH POINT
21' - 6 3/4"
L
2 A-401
3 A-401
J
W4 W4 W4 W4 W4 W4 W4
W3 W3 W3 W3 W3
TYP
2' - 2"
10 W1 W1
A-821
9 A-821
11 A-821
4 A-830
1 A-830
5 A-822
T
Y
P
2' - 3"
A-811
1 A-811
2 7.6
7.14 SW 7025
SW 7025
5.8 5.28
8.21 5.32 5.31 5.30 5.29 5.31 5.32
6.17 PURPLE GREEN YELLOW MAGENTA GREEN PURPLE
5.15 10.13
8.21 A. SEE G010 AND A850 FOR STANDARD
ACCESSIBILITY REQUIREMENTS.
B. SEE ENLARGED PLANS FOR ADDITIONAL
INFORMATION.
C. SEE ENLARGED PLANS AND EXTERIOR WINDOW
SCHEDULE FOR SIZE AND TYPE OF WINDOW.
D. ALL DIMENSIONS ARE TO FACE OF STUD UNO OR
CENTER OF WINDOW OPENING, COLUMN,
EXTERIOR DIMENSIONS ARE TO FACE OF
FOUNDATION/FACE OF FRAMING. DIMENSIONS
INDICATED AS “CLR” ARE TO FACE OF FINISH
UNO.
E. ALL DOOR OPENINGS PERPENDICULAR TO A WALL
ARE 4” TO FACE OF PERP STUD UNO.
F. SEE A851 FOR PENETRATION REQUIREMENTS.
G. ALL FIXTURES, FURNISHINGS & EQUIPMENT NOT
IN CONTRACT SHOWN DASHED FOR REFERENCE
ONLY.
H. DASHED BOXES AND CIRCLES ON PLAN
DESIGNATE REQUIRED ACCESSIBLE OR
EQUIPMENT CLEAR FLOOR SPACE.
I. ALL JANITOR CLOSETS TO HAVE WATER
RESISTANT GYP BOARD AT WALLS.
J. SEE A850 FOR FIXTURE AND ACCESSORY
MOUNTING HEIGHTS, BLOCKING AND
CLEARANCES
K. SIGNAGE IS TO BE MOUNTED ON ALL FDC’S
SERVING AUTOMATIC SPRINKLERS, STANDPIPES
OR FIRE PUMP CONNECTIONS.
FCP1 - FIBER CEMENT PANEL, PAINTED
SW 7727
FCL1 - FIBER CEMENT LAP SIDING
SW 9166
FCP2 - FIBER CEMENT PANEL, PAINTED
SW 7025
FCP3 - FIBER CEMENT PANEL, PAINTED
SW 7026
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
12 11 10 9 8 7 6 5 4 2 1
2 A-402
HIGH POINT
21' - 6 3/4"
3 BREEZEWAY
3 A-402
1 A-401
6.1 T.O. PLATE AT
SHED
19' - 6 3/4"
W3 W3 W3 W3 W3 W3 W3 W3 W3 W3
W1 W1 W1 W1 W1 W1 BREEZEWAY
EQEQ EQEQ
EXISTING BUILDING
A-301
3 7.6
7.6 7
A-822
2 A-830
8 A-830
14 A-821
13 A-821
16 A-821
T
Y
P
2' - 3"
SW 9166
SW 9166 5.8
5.15 5.31 5.29 5.30 5.32 5.31 5.30 5.29 5.30 5.31 5.30 5.29
5.28 GREEN MAGENTA YELLOW PURPLE GREEN YELLOW MAGENTA YELLOW GREEN YELLOW MAGENTA
5.32 PURPLE
5.32 PURPLE
8 A-411
T.O. PLATE
9' - 0"
12 11 10 9 8 7 6 5 4
2 A-402
HIGH POINT
21' - 6 3/4"
1 A-401
6.1 T.O. PLATE AT
SHED
19' - 6 3/4"
W2 W2 W2 W2 W2 W2 W2 W2 W2 W2 W2 W2 W2 W2
T
Y
P
4' - 0"
5.28 8
A-411
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:0
9 A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
EXTERIOR
ELEVATIONS
A-301
EN, KS, JL
AS
06/26/24
3/16" = 1'-0"A-301
1 EAST ELEVATION
GENERAL NOTES
MATERIALS LEGEND
KEYNOTES
5.8 PARAPET COPING, PAINTED, TYP. SW
9166
5.15 HSS STEEL TUBE, PAINTED, TYP., SW 7025
5.28 METAL FASCIA, PAINTED, TYP., SW 7025
5.29 METAL SURROUND, PAINTED, TYP., SW
6579
5.30 METAL SURROUND, PAINTED, TYP., SW
6677
5.31 METAL SURROUND, PAINTED, TYP., SW
6732
5.32 METAL SURROUND, PAINTED, TYP., SW
6981
6.17 PAINTED COLUMN & BEAM, TYP. SEE
STRUCTURAL, SW 7025
7.6 DOWNSPOUT; WITH THROUGH WALL
SCUPPER AT PARAPETS; PAINTED, TYP.,
PAINT COLOR INDICATED ON ELEVATION
7.14 METAL GUTTER, PAINTED, TYP. PAINT
COLOR INDICATED ON ELEVATIONS
8.21 DOOR ACTUATOR MOUNTED AT 42" AFF
TO TOP OF OPERABLE PARTS
10.13 SUNSHADE FABRIC, TYP., CLASS A FIRE
SPREAD FABRIC
3/16" = 1'-0"A-301
2 NORTH ELEVATION
0 4' 8' 12'
3/16" = 1'-0"A-301
3 NORTH ELEVATION - SECOND STORY
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
12456789 10 11 12 2
A-402
HIGH POINT
21' - 6 3/4"
3 EXISTING
BUILDING
3 A-402
1 A-401
6.1 W4 W4
22.7 BREEZEWAY 10
A-822
9 A-822
11 A-822
18 A-821
17 A-821
19 A-821
3 A-830
3' - 1"
A-822 6
TYP
A-811 3 TYP
A-811 4
A-811 5
7.6 SW 7025
7.14 SW 7025
SW 9166 7.6 5.8
10.13 6.17
5.15 8
A-411
2' - 6"
12 A-821
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
1 A-402
ABCDEFGHK
HIGH POINT
21' - 6 3/4"
L
2 3 A-401
A-401
T.O. PLATE AT
SHED
19' - 6 3/4"
NOTE: ALL WINDOWS ON WEST
ELEVATION TO BE FROSTED
W1 W1 W1 W1 W1 W1 W1 8
A-830
15 A-821
TYP
2' - 3"
AT CHANNEL 7
A-822
W5
EQ EQ EQ EQ
5.15 7.6 SW 9166
5.8 10.13
5.28 5.15
8.2 15
A-822
A. SEE G010 AND A850 FOR STANDARD
ACCESSIBILITY REQUIREMENTS.
B. SEE ENLARGED PLANS FOR ADDITIONAL
INFORMATION.
C. SEE ENLARGED PLANS AND EXTERIOR WINDOW
SCHEDULE FOR SIZE AND TYPE OF WINDOW.
D. ALL DIMENSIONS ARE TO FACE OF STUD UNO OR
CENTER OF WINDOW OPENING, COLUMN,
EXTERIOR DIMENSIONS ARE TO FACE OF
FOUNDATION/FACE OF FRAMING. DIMENSIONS
INDICATED AS “CLR” ARE TO FACE OF FINISH
UNO.
E. ALL DOOR OPENINGS PERPENDICULAR TO A WALL
ARE 4” TO FACE OF PERP STUD UNO.
F. SEE A851 FOR PENETRATION REQUIREMENTS.
G. ALL FIXTURES, FURNISHINGS & EQUIPMENT NOT
IN CONTRACT SHOWN DASHED FOR REFERENCE
ONLY.
H. DASHED BOXES AND CIRCLES ON PLAN
DESIGNATE REQUIRED ACCESSIBLE OR
EQUIPMENT CLEAR FLOOR SPACE.
I. ALL JANITOR CLOSETS TO HAVE WATER
RESISTANT GYP BOARD AT WALLS.
J. SEE A850 FOR FIXTURE AND ACCESSORY
MOUNTING HEIGHTS, BLOCKING AND
CLEARANCES
K. SIGNAGE IS TO BE MOUNTED ON ALL FDC’S
SERVING AUTOMATIC SPRINKLERS, STANDPIPES
OR FIRE PUMP CONNECTIONS.
FCP1- FIBER CEMENT PANEL, PAINTED
SW 7727
FCL1- FIBER CEMENT LAP SIDING
SW 9166
FCP2- FIBER CEMENT PANEL, PAINTED
SW 7025
FCP3- FIBER CEMENT PANEL, PAINTED
SW 7026
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
NEW
BUILDING
TRENCH DRAIN SLOPE
S
L
O
P
E
EXISTING
BUILDING
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
2222 NE OREGON ST.
SUITE 101
PORTLAND, OR 97232
PHONE: 503.702.2575
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:30:12 AM
C:\Users\enavarro\Documents\_RevitLocal\2321 24_0903 Shelter Expansion_R21_enavarroQT4G7.rvt 2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
EXTERIOR
ELEVATIONS
A-302
EN, KS, JL
AS
08/22/24
A-302 3/16" = 1'-0" 1 SOUTH ELEVATION
3/16" = 1'-0"A-302 2 WEST ELEVATION
GENERAL NOTES
MATERIALS LEGEND
KEYNOTES
5.8 PARAPET COPING, PAINTED, TYP. SW
9166
5.15 HSS STEEL TUBE, PAINTED, TYP., SW 7025
5.28 METAL FASCIA, PAINTED, TYP., SW 7025
6.17 PAINTED COLUMN & BEAM, TYP. SEE
STRUCTURAL, SW 7025
7.6 DOWNSPOUT; WITH THROUGH WALL
SCUPPER AT PARAPETS; PAINTED, TYP.,
PAINT COLOR INDICATED ON ELEVATION
7.14 METAL GUTTER, PAINTED, TYP. PAINT
COLOR INDICATED ON ELEVATIONS
8.2 WALL CAP VENT – COLOR TO MATCH
ADJACENT WALL, PAINTED.
10.13 SUNSHADE FABRIC, TYP., CLASS A FIRE
SPREAD FABRIC
22.7 HOSE BIBB
0 4' 8' 12'
1/4" = 1'-0"A-302 3 DETAIL SECTION - BREEZEWAY
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
1 2 4 5 6 7 8 9 10 11 12
2 A-402
HIGH POINT
21' - 6 3/4"
3 3
A-402
1 A-401
6.1 3
3 7B
2 10
7A
7A
10 1
10 HALLWAY 1
113
COMMERCIAL
KITCHEN
119
HALLWAY 5
106
CASE
MANAGEMENT
111
TYP
8" MIN
A-830
4 SIM
A-411
4 A-411
3 SIM
2 8' - 0"
REFRIGERATOR
119F
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
12 11 10 9 8 7 6 5 4 2 1
2 A-402
HIGH POINT
21' - 6 3/4"
3 3
A-402
1 A-401
6.1 T.O. PLATE AT
SHED
19' - 6 3/4"
2 3
10 HALLWAY 3
130
1 A-411
3 SIM
A-411
5 8
A-411
NOT RATED
1HR RATED
A. REFER TO G-010 FOR ENERGY CODE
COMPLIANCE REQUIREMENTS.
B. SEE WALL SECTIONS AND DETAILS FOR
INFORMATION ON CONTINUITY OF ALL EXTERIOR
CONTROL LAYERS.
C. WHERE EXTERIOR ELEMENTS INTERFACE WITH
INTERIOR SEE ENLARGED PLAN SHEETS FOR
ADDITIONAL INFORMATION.
D. TYPICAL ROOF CONDITIONS SHOWN - SEE ROOF
PLANS FOR ROOF CONFIGURATION AND PITCH.
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
1 A B C D A-402 E F G K
HIGH POINT
21' - 6 3/4"
L
2 A-401
3 A-401
J
T.O. PLATE AT
SHED
19' - 6 3/4"
7A 7A 5B
10 5A 7A
10 7A
5A
7A
8A
10 1
2 3
3 NC-7
134
HALLWAY 3
130
LAUNDRY
129
ADMINISTRATION
OFFICE
128
MEDICATION
127
WAITING AREA
105
OFFICE
107
STAFF
RESTROOM
108
ELECTRICAL
123
TYP
A-411
1 A-411
2 A-411
3 1' - 8"
1 1/2" / 1'-0"
3 2' - 0"
2' - 0"
BATT INSULATE ABOVE
WALLS THAT DO NOT
STOP AT PRIMARY
STRUCTURAL ROOF
2 REFRIGERATOR
119F
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:13
A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
BUILDING
SECTIONS
A-401
EN, KS, JL
AS
01/03/19
3/16" = 1'-0"A-401
2 BUILDING SECTION 2 - EW
3/16" = 1'-0"A-401
3 BUILDING SECTION 3 - EW
ASSEMBLY FIRE RATINGS
GENERAL NOTES
0 4' 8' 12'
3/16" = 1'-0"A-401
1 BUILDING SECTION 1 - NS
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
1 2 4 6 7 8 9 10 11 12
2 A-402
HIGH POINT
21' - 6 3/4"
3 3
A-402
1 A-401
6.1 2
3 1
10 3
2 10
HALLWAY 1
113
ENTRY
101
WAITING AREA
105
HALLWAY 4
149
10 A-411
6 A-411
3 SIM
2 LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
1 A-402
L K H G F E D C B A
2 A-401
3 A-401
3 2
HALLWAY 1
113
MEN'S
BATHROOM
118
UTILITY /
STORAGE
117
STORAGE LINEN
115
HALLWAY 1
113
WOMEN'S
BATHROOM
148
HALLWAY 3
130
NC-2
139
7B 7B 5B
7A
10 5A 5A 7A
7A 7A
10 1
A-411
3 A-411
3 SIM
OPP
2 8" MIN
TYP
OFFICE
119B
RESTROOM
119C
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
1 A-402
K H G F E D C B A
HIGH POINT
21' - 6 3/4"
L
2 A-401
3 A-401
J
T.O. PLATE AT
SHED
19' - 6 3/4"
3 3 TYP
2 HALLWAY 5
106
WAITING AREA
105
WAITING AREA
125
HALLWAY 2
126
NC-8
133
10 2
1 7A
10 7A
A-411
4 OPP
A-411
3 SIM
OPP
A-411
7 1' - 8"
10 NOT RATED
1HR RATED
A. REFER TO G-010 FOR ENERGY CODE
COMPLIANCE REQUIREMENTS.
B. SEE WALL SECTIONS AND DETAILS FOR
INFORMATION ON CONTINUITY OF ALL EXTERIOR
CONTROL LAYERS.
C. WHERE EXTERIOR ELEMENTS INTERFACE WITH
INTERIOR SEE ENLARGED PLAN SHEETS FOR
ADDITIONAL INFORMATION.
D. TYPICAL ROOF CONDITIONS SHOWN - SEE ROOF
PLANS FOR ROOF CONFIGURATION AND PITCH.
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:14
A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
BUILDING
SECTIONS
A-402
EN, KS, JL
AS
07/10/24
3/16" = 1'-0"A-402
1 BUILDING SECTION 4 - EW
3/16" = 1'-0"A-402
3 BUILDING SECTION 6 - NS
3/16" = 1'-0"A-402
2 BUILDING SECTION 5 - NS
0 4' 8' 12'
ASSEMBLY FIRE RATINGS
GENERAL NOTES
A. REFER TO A-811 FOR FENESTRATION SCHEDULE
AND G-010 FOR ENERGY CODE COMPLIANCE
REQUIREMENTS.
B. SEE BUILDING SECTIONS FOR INFORMATION ON
CONTINUITY OF ALL EXTERIOR CONTROL LAYERS.
C. WHERE EXTERIOR ELEMENTS INTERFACE WITH
INTERIOR, SEE ENLARGED PLAN SHEETS FOR
ADDITIONAL INFOMRATION.
D. TYPICAL ROOF CONDITIONS SHOWN - SEE ROOF
PLANS FOR ROOF CONFIGURATION AND PITCH.
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
K L
10 1' - 3"
A-830
3 A-822
1 A-822
3 BEAM PER STRUCTURAL
COLUMN PER
STRUCTURAL -BEYOND
TRUSS BLOCKING
WITH DRAFT STOP
2' - 3 1/2"
1 2
TYP AT SIDEWALK
TYP AT WALL TO ROOF
TRUSS BLOCKING
INTERIOR EXTERIOR
BULK WATER BARRIER /
VAPOR RETARDER - SEE
DETAILS -TYP
T.O. PLATE
9' - 0"
D
T.O. PLATE AT
SHED
19' - 6 3/4"
TRUSS BLOCKING
WITH DRAFT STOP
A-830
5 3
7A
10 2
3 A-830
2 TRUSS BLOCKING
A-822
3 SIM
SIM
INTERIOR
INTERIOR
EXTERIOR
2 LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
A
A-830
4 A-830
8 AT SCUPPER
10 1
3 2
EXTERIOR INTERIOR
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
A-830
1 10
2 A-821
9 A-821
11 TYP AT WINDOW
TYP AT WINDOW
1' - 2"
1 TRUSS BLOCKING
WITH DRAFT STOP
INTERIOR EXTERIOR
3 LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
A-830
4 A-822
9 A-821
20 NEW CANOPY
STRUCTURE
R-14 MIN BATT INSULATION
R-17 MIN BATT INSULATION
A-822
4 TYP AT DOOR AT SIDEWALK
1 A-830
5 A-822
6 EXTERIOR INTERIOR
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
12 HIGH POINT
21' - 6 3/4"
R-14 MIN BATT INSULATION
A-821
19 A-822
4 SIM
10 2
3 1' - 2"
A-830
1 1
INTERIOR EXTERIOR
LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
3 TRUSS BLOCKING 2
WITH DRAFT STOP
A-821
19 1
EXTERIOR INTERIOR
10 LEVEL 1
0' - 0"
T.O. PLATE
9' - 0"
T.O. PARAPET
14' - 6"
K
10"
WALL MOUNTED
ROLL UP DOOR
PER SPECS
3' - 1"
2' - 6"
1 10
3 2
A-821
12 A-821
19 PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:16
A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
WALL SECTIONS
A-411
EN, KS, JL
AS
01/03/19
GENERAL NOTES
0 1' 2' 4'
A-411 1/2" = 1'-0"
1 WALL SECTION 1
A-411 1/2" = 1'-0"
2 WALL SECTION 2
A-411 1/2" = 1'-0"
3 WALL SECTION 3
A-411 1/2" = 1'-0"
4 WALL SECTION 4
1/2" = 1'-0"A-411
5 WALL SECTION 5
1/2" = 1'-0"A-411
6 WALL SECTION 6
1/2" = 1'-0"A-411
7 WALL SECTION 7
1/2" = 1'-0"A-411
8 WALL SECTION 8
A. SEE G010 AND A850 FOR STANDARD
ACCESSIBILITY REQUIREMENTS.
B. SEE ENLARGED PLANS FOR ADDITIONAL
INFORMATION.
C. SEE ENLARGED PLANS AND EXTERIOR WINDOW
SCHEDULE FOR SIZE AND TYPE OF WINDOW.
D. ALL DIMENSIONS ARE TO FACE OF STUD UNO OR
CENTER OF WINDOW OPENING, COLUMN,
EXTERIOR DIMENSIONS ARE TO FACE OF
FOUNDATION/FACE OF FRAMING. DIMENSIONS
INDICATED AS “CLR” ARE TO FACE OF FINISH
UNO.
E. ALL DOOR OPENINGS PERPENDICULAR TO A WALL
ARE 4” TO FACE OF PERP STUD UNO.
F. SEE A851 FOR PENETRATION REQUIREMENTS.
G. ALL FIXTURES, FURNISHINGS & EQUIPMENT NOT
IN CONTRACT SHOWN DASHED FOR REFERENCE
ONLY.
H. DASHED BOXES AND CIRCLES ON PLAN
DESIGNATE REQUIRED ACCESSIBLE OR
EQUIPMENT CLEAR FLOOR SPACE.
I. ALL JANITOR CLOSETS TO HAVE WATER
RESISTANT GYP BOARD AT WALLS.
J. SEE A850 FOR FIXTURE AND ACCESSORY
MOUNTING HEIGHTS, BLOCKING AND
CLEARANCES
K. SIGNAGE IS TO BE MOUNTED ON ALL FDC’S
SERVING AUTOMATIC SPRINKLERS, STANDPIPES
OR FIRE PUMP CONNECTIONS.
G
H
4 5
K
6 6.1 7
3' - 0 1/2"
8' - 4 1/2" 3' - 0"
4' - 11 1/2"
8' - 3 1/2"
8' - 6 1/2" 7' - 11 1/2"
7' - 11"
2' - 5 1/2"
119B 119C
119A
119D
119E
W6
2' - 4"
PANTRY
119E
REFRIGERATOR
119F
FREEZER
119G
COMMERCIAL
KITCHEN
119
OFFICE
119B
RESTROOM
119C
RANGE HOOD ABOVE
1' - 2 1/4"
1' - 1 3/8"
15' - 7 1/2"
10' - 7"
10' - 6"
8 A-411
A-600 14
15 16
13 C
D
A-600
10 12
11 9
2' - 2" 3' - 10" 4' - 7" 5' - 0" 3' - 10" 5' - 7"
4' - 0" 8' - 0"
124A
124B
1 A-855
TYP
GROUP
COUNSELING
124
W6
W6
24"
CPT-3
CPT-4
3' - 10" 3' - 10"
3' - 10" 3' - 10"
ACCENT PAINT
ACCENT PAINT
33" 33" 30"
3 6" 20" 3
4"
32"
12.15 12.13 11.4
ACCENT PAINT
3 4" 20" 3
6"
47"
24"34"34"34"34"34"24"4"
CASEWORK BLANK
PANEL AT EACH END
12.13 ACCENT PAINT
ACCENT PAINT
3' - 0"
A-600
17 TYP
A-600 6
5 6.1
3' - 2" 7' - 7 1/2"
12' - 0"
6' - 3" 6' - 3"
4' - 5" CLR
BUILT IN BENCH
SEATING
W6 W6
143A142A
129
DAY ROOM
141
CPT-3
CONC-1
ACCENT PAINT
2 A-855
7 3' - 0"3' - 0"
LIGHT GUAGE
METAL FRAMING
3"
STRIP LIGHT,
SEE ELECTRICAL
LIGHT GUAGE
METAL ANGLE
J-TRIM AT EDGE
1 1/2"
A-855
2 6.18
AND AT
WALL ENDS
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:19
A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
ENLARGED
PLANS &
ELEVATIONS
A-600
EN, KS, JL
AS
01/14/22
GENERAL NOTES
KEYNOTES
6.18 COMPOSITE WOOD ACCENT
11.4 UNDER COUNTER MINI FRIDGE - SEE
SPECIFICATIONS
12.13 SOLID SURFACE COUNTERTOP AND 4"
HIGH BACKSPLASH PER SPECIFICATIONS
12.15 CASEWORK SHROUD PANEL -
COORIDNATE WITH SINK DEPTH AND
ACCESSIBILITY KNEE CLEARANCE
REQUIREMENTS - CAP AT EXPOSED ENDS
1/4" = 1'-0"A-600
4 COMMERCIAL KITCHEN
1/4" = 1'-0"A-600
3 TYPICAL NON-CONGREGATE ROOM
0 2' 4' 8'
1/4" = 1'-0"A-600
1 GROUP COUNSELING
1/4" = 1'-0"A-600
6 DAY USE EAST
1/4" = 1'-0"A-600
10 GROUP COUNSELING SOUTH
1/4" = 1'-0"A-600
12 GROUP COUNSELING NORTH
1/4" = 1'-0"A-600
11 GROUP COUNSELING WEST
1/4" = 1'-0"A-600
9 GROUP COUNSELING EAST
1/4" = 1'-0"A-600
2 DAY USE
1/4" = 1'-0"A-600
5 DAY USE SOUTH
A-600 1/4" = 1'-0"
13 TYP NC NORTH
A-600 1/4" = 1'-0"
14 TYP NC EAST
A-600 1/4" = 1'-0"
15 TYP NC SOUTH
A-600 1/4" = 1'-0"
16 TYP NC WEST
3" = 1'-0"A-600
17 COVE LIGHT
1/4" = 1'-0"A-600
7 DAY USE NORTH
C
D
3 4 5 6
WOMEN'S
BATHROOM
148
MEN'S
BATHROOM-NC
147
WOMEN'S
BATHROOM-NC
144
A-601 1E
A-601
1G
A-601
1D
1F
1C
1B
A-601
2' - 0"
1' - 0"
3' - 8"
16' - 8 1/2" 6' - 6 1/2"
6"
3' - 6"
11 1/2"
2' - 2"
1A A-601
1C SIM
B46
148A
147A144A
147B144B
SEE FOR
ACCESSIBILITY REQUIREMENTS
1 / A-850
1' - 5"
3' - 5
5/8" 3' - 2 1/2" 3' - 0
3/4" 3' - 0
3/4" 7' - 4 1/4"
1' - 9"
3' - 4
3/4" 5' - 3 1/4" 10"
10 1/4"
T
Y
P
3' - 1 1/4"
24"
CLR
18"
CLR
18"
10.9 A. SEE G010 AND A850 FOR STANDARD
ACCESSIBILITY REQUIREMENTS.
B. SEE ENLARGED PLANS FOR ADDITIONAL
INFORMATION.
C. SEE ENLARGED PLANS AND EXTERIOR WINDOW
SCHEDULE FOR SIZE AND TYPE OF WINDOW.
D. ALL DIMENSIONS ARE TO FACE OF STUD UNO OR
CENTER OF WINDOW OPENING, COLUMN,
EXTERIOR DIMENSIONS ARE TO FACE OF
FOUNDATION/FACE OF FRAMING. DIMENSIONS
INDICATED AS “CLR” ARE TO FACE OF FINISH
UNO.
E. ALL DOOR OPENINGS PERPENDICULAR TO A WALL
ARE 4” TO FACE OF PERP STUD UNO.
F. SEE A851 FOR PENETRATION REQUIREMENTS.
G. ALL FIXTURES, FURNISHINGS & EQUIPMENT NOT
IN CONTRACT SHOWN DASHED FOR REFERENCE
ONLY.
H. DASHED BOXES AND CIRCLES ON PLAN
DESIGNATE REQUIRED ACCESSIBLE OR
EQUIPMENT CLEAR FLOOR SPACE.
I. ALL JANITOR CLOSETS TO HAVE WATER
RESISTANT GYP BOARD AT WALLS.
J. SEE A850 FOR FIXTURE AND ACCESSORY
MOUNTING HEIGHTS, BLOCKING AND
CLEARANCES
K. SIGNAGE IS TO BE MOUNTED ON ALL FDC’S
SERVING AUTOMATIC SPRINKLERS, STANDPIPES
OR FIRE PUMP CONNECTIONS.
B50
B49
B49
B50
B43
B10 B49
B47
B48 B10
B47
17" 30" 30" 30" 17"
B48 B49
B50
E
G
F
4 5 6 7
LAUNDRY
114
MEN'S
BATHROOM
118
A-601
2A
2B
A-601
2E
2D
2C
6.1 11"
3' - 6"
4' - 0" 4' - 0" 4' - 0" 4' - 0" 3' - 7 1/2"
1' - 2 1/2"
1' - 1"
7' - 0"
2' - 8 1/2" 3' - 11" 3' - 0"
3' - 0"
W6 W6 W6
24"
1' - 8"
115A
114A
118A
SEE FOR
ACCESSIBILITY REQUIREMENTS
1 / A-850
3' - 4 1/2" 3' - 2 7/8" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" 3' - 0 3/4" TYP
5' - 3 1/4" 3' - 1 1/4" 6"
10 1/2"
24"
W6 W6
10.9 10.9
12.13 B48 B49
B50
10.9 B44
B10
B47 B48
17" 17"30"30"30"30"
154"
10.9 B50
3' - 3"
36"36"36"
12.13 D
W
D
W
D
W
D
W
D
W
D
WW WD D
24"36"
12.13 3C A-601
3A
3B
3D
1' - 6"
SEE FOR
ACCESSIBILITY REQUIREMENTS
1 / A-850
B43
B26
B50
B21
B13
B44
B21
B10
B46
B50
B49
B46
B50
B10
B47
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:24
A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
ENLARGED
PLANS &
ELEVATIONS
A-601
EN, KS, JL
AS
07/16/24
1/4" = 1'-0"A-601
1 WOMEN'S RESTROOM & NC RESTROOMS
GENERAL NOTES
KEYNOTES
10.9 CHANGING BENCH, CFCI
12.13 SOLID SURFACE COUNTERTOP AND 4"
HIGH BACKSPLASH PER SPECIFICATIONS
B10 SURFACE MOUNTED MIRROR 30X42. TYP
B13 TOILET TISSUE DISPENSER.
B21 GRAB BAR.
B26 SOAP DISPENSER.
B43 PAPER TOWEL DISPENSER.
B44 TOILET SEAT COVER DISPENSER.
B46 BABY CHANGING STATION
B47 HOSE BIB MOUNTED 18" AFF
B48 SHOWER
B49 ADA SHOWER COMPARTMENT
B50 WALL BASE, SEE ROOM SCHEDULE
A-601 1/4" = 1'-0"
1G SHOWER RM WALL
A-601 1/4" = 1'-0"
1F SHOWER RM TYP
1/4" = 1'-0"A-601
1C BATHROOM-NC
1/4" = 1'-0"A-601
1B MEN'S BATHROOM-NC
1/4" = 1'-0"A-601
1E WOMEN'S RESTROOM
1/4" = 1'-0"A-601
1D WOMEN'S BATHROOM
1/4" = 1'-0"A-601
2 LAUNDRY & MEN'S BATHROOM
1/4" = 1'-0"A-601
2B MEN'S BATHROOM SOUTH
1/4" = 1'-0"A-601
2A MEN'S BATHROOM NORTH
1/4" = 1'-0"A-601
2E LAUNDRY ROOM NORTH
1/4" = 1'-0"A-601
2D LAUNDRY ROOM SOUTH
1/4" = 1'-0"A-601
3 STAFF RESTROOM
1/4" = 1'-0"A-601
3A STAFF RR NORTH
1/4" = 1'-0"A-601
3B STAFF RR SOUTH
1/4" = 1'-0"A-601
3C STAFF RR WEST
1/4" = 1'-0"A-601
3D STAFF RR EAST
1/4" = 1'-0"A-601
2C LAUNDRY ROOM EAST
1/4" = 1'-0"A-601
1A WOMEN'S BATHROOM-NC
D
E
4 5 6.1
A-602
2 3
8.21 WAITING AREA
105 W6 W6 W6
W8
W8
143B142B
104
146145
149A114A
116A
103102
101A
8' - 3" 10' - 2 1/2" 12' - 9" 6' - 0" 9' - 1"
3' - 0"
6' - 4"
W6 W6
A-855
9 1' - 1" 3' - 7 1/2" 7' - 7" 11' - 3" 7' - 1 1/2" 11' - 3" 7' - 11" 3' - 11 1/2"
14' - 4 1/2"
ACCENT PAINT
ACCENT PAINT
OPEN TO BEYOND
3' - 0"
13' - 0"
FOUR PAINT COLORS.
SHAPE/PATTERN TBD.
12.13 OPEN TO BEYOND
OPEN TO BEYOND
3' - 3"
3' - 0"
8.21 FOUR PAINT COLORS.
SHAPE/PATTERN TBD.
A. SEE G010 AND A850 FOR STANDARD
ACCESSIBILITY REQUIREMENTS.
B. SEE ENLARGED PLANS FOR ADDITIONAL
INFORMATION.
C. SEE ENLARGED PLANS AND EXTERIOR WINDOW
SCHEDULE FOR SIZE AND TYPE OF WINDOW.
D. ALL DIMENSIONS ARE TO FACE OF STUD UNO OR
CENTER OF WINDOW OPENING, COLUMN,
EXTERIOR DIMENSIONS ARE TO FACE OF
FOUNDATION/FACE OF FRAMING. DIMENSIONS
INDICATED AS “CLR” ARE TO FACE OF FINISH
UNO.
E. ALL DOOR OPENINGS PERPENDICULAR TO A WALL
ARE 4” TO FACE OF PERP STUD UNO.
F. SEE A851 FOR PENETRATION REQUIREMENTS.
G. ALL FIXTURES, FURNISHINGS & EQUIPMENT NOT
IN CONTRACT SHOWN DASHED FOR REFERENCE
ONLY.
H. DASHED BOXES AND CIRCLES ON PLAN
DESIGNATE REQUIRED ACCESSIBLE OR
EQUIPMENT CLEAR FLOOR SPACE.
I. ALL JANITOR CLOSETS TO HAVE WATER
RESISTANT GYP BOARD AT WALLS.
J. SEE A850 FOR FIXTURE AND ACCESSORY
MOUNTING HEIGHTS, BLOCKING AND
CLEARANCES
K. SIGNAGE IS TO BE MOUNTED ON ALL FDC’S
SERVING AUTOMATIC SPRINKLERS, STANDPIPES
OR FIRE PUMP CONNECTIONS. PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:25
A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
ENLARGED
PLANS &
ELEVATIONS
A-602
EN, KS, JL
AS
09/24/24
1/4" = 1'-0"A-602
1 HALLWAY 1
A-602 1/4" = 1'-0"
2 HALLWAY 1 NORTH
1/4" = 1'-0"A-602
3 HALLWAY 1 SOUTH
GENERAL NOTES
KEYNOTES
8.21 DOOR ACTUATOR MOUNTED AT 42" AFF
TO TOP OF OPERABLE PARTS
12.13 SOLID SURFACE COUNTERTOP AND 4"
HIGH BACKSPLASH PER SPECIFICATIONS
C
D
5 B
4 6.1
A-603
2 3
LAUNDRY
129
ADMINISTRATION
OFFICE
128
MEDICATION
127
WAITING AREA
125
HALLWAY 2
126
HALLWAY 3
130
ACCENT PAINT
ACCENT PAINT
ACCENT PAINT
8.21 2"
6.18 3' - 0"
COMPOSITE
WOOD FRAME
10.14 4' - 0"
3' - 0"
6"
ACCENT PAINT
OPEN TO BEYOND OPEN TO
BEYOND
8.21 OPEN TO BEYOND
2"
ACCENT PAINT
A. SEE G010 AND A850 FOR STANDARD
ACCESSIBILITY REQUIREMENTS.
B. SEE ENLARGED PLANS FOR ADDITIONAL
INFORMATION.
C. SEE ENLARGED PLANS AND EXTERIOR WINDOW
SCHEDULE FOR SIZE AND TYPE OF WINDOW.
D. ALL DIMENSIONS ARE TO FACE OF STUD UNO OR
CENTER OF WINDOW OPENING, COLUMN,
EXTERIOR DIMENSIONS ARE TO FACE OF
FOUNDATION/FACE OF FRAMING. DIMENSIONS
INDICATED AS “CLR” ARE TO FACE OF FINISH
UNO.
E. ALL DOOR OPENINGS PERPENDICULAR TO A WALL
ARE 4” TO FACE OF PERP STUD UNO.
F. SEE A851 FOR PENETRATION REQUIREMENTS.
G. ALL FIXTURES, FURNISHINGS & EQUIPMENT NOT
IN CONTRACT SHOWN DASHED FOR REFERENCE
ONLY.
H. DASHED BOXES AND CIRCLES ON PLAN
DESIGNATE REQUIRED ACCESSIBLE OR
EQUIPMENT CLEAR FLOOR SPACE.
I. ALL JANITOR CLOSETS TO HAVE WATER
RESISTANT GYP BOARD AT WALLS.
J. SEE A850 FOR FIXTURE AND ACCESSORY
MOUNTING HEIGHTS, BLOCKING AND
CLEARANCES
K. SIGNAGE IS TO BE MOUNTED ON ALL FDC’S
SERVING AUTOMATIC SPRINKLERS, STANDPIPES
OR FIRE PUMP CONNECTIONS. PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:27 A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
ENLARGED
PLANS &
ELEVATIONS
A-603
EN, KS, JL
AS
10/10/24
1/4" = 1'-0"A-603
1 HALLWAY 2 AND 3
A-603 1/4" = 1'-0"
2 NC HALLWAY SOUTH
1/4" = 1'-0"A-603
3 NC HALLWAY NORTH
GENERAL NOTES
KEYNOTES
6.18 COMPOSITE WOOD ACCENT
8.21 DOOR ACTUATOR MOUNTED AT 42" AFF
TO TOP OF OPERABLE PARTS
10.14 LOCKABLE DISPLAY UNIT
11' - 4"
20' - 0"
1.5%
12 12
12 12
12 2CY BIN -TYP
A-604 4
6" CONCRETE
CURBA-604
3 3
A-604
A-604 2
SIM
5 A-604
EA SIDE
3' - 0" FOOTING BELOW
A-604 6
EMBED PLATE -TYP
AT EACH COLUMN
4x4 HSS -TYP, SEE
STRUCTURAL
A. SEE G010 AND A850 FOR STANDARD
ACCESSIBILITY REQUIREMENTS.
B. SEE ENLARGED PLANS FOR ADDITIONAL
INFORMATION.
C. SEE ENLARGED PLANS AND EXTERIOR WINDOW
SCHEDULE FOR SIZE AND TYPE OF WINDOW.
D. ALL DIMENSIONS ARE TO FACE OF STUD UNO OR
CENTER OF WINDOW OPENING, COLUMN,
EXTERIOR DIMENSIONS ARE TO FACE OF
FOUNDATION/FACE OF FRAMING. DIMENSIONS
INDICATED AS “CLR” ARE TO FACE OF FINISH
UNO.
E. ALL DOOR OPENINGS PERPENDICULAR TO A WALL
ARE 4” TO FACE OF PERP STUD UNO.
F. SEE A851 FOR PENETRATION REQUIREMENTS.
G. ALL FIXTURES, FURNISHINGS & EQUIPMENT NOT
IN CONTRACT SHOWN DASHED FOR REFERENCE
ONLY.
H. DASHED BOXES AND CIRCLES ON PLAN
DESIGNATE REQUIRED ACCESSIBLE OR
EQUIPMENT CLEAR FLOOR SPACE.
I. ALL JANITOR CLOSETS TO HAVE WATER
RESISTANT GYP BOARD AT WALLS.
J. SEE A850 FOR FIXTURE AND ACCESSORY
MOUNTING HEIGHTS, BLOCKING AND
CLEARANCES
K. SIGNAGE IS TO BE MOUNTED ON ALL FDC’S
SERVING AUTOMATIC SPRINKLERS, STANDPIPES
OR FIRE PUMP CONNECTIONS.
1 /4
"
/
1 '-
0"
4x4 HSS, SEE
STRUCTURAL
3" DEEP
CORRUGATED
METAL ROOF
DRIP FLASHING BELOW
DECKING AT LOW END
AND ABOVE DECKING
AT HIGH END
5 A-604
4x4 HSS, SEE
STRUCTURAL
3" DEEP
CORRUGATED
METAL ROOF
5 A-604
4x4 HSS, SEE
STRUCTURAL
3" DEEP
CORRUGATED
METAL ROOF
6' - 0"
6" MIN
8" 1' - 0"
2' - 0"
PROPERTY LINE
8"
SLOPED CMU
TOP CAP
4x4 HSS, SEE
STRUCTURAL
CORRUGATED
METAL ROOF
DECKING
8" CMU WALL
GROUTED SOLID W/ #
4 VERT AT 16" O.C., (2)
#4 VERT AT WALL
ENDS AND CORNERS.
BOND BEAMS: (2) #4
HORIZ AT TOP BEAM
AND 48" HIGH BEAM
6" CONCRETE CURB
4' - 0"
(2) #4 CONTINUOUS #5 AT 18" O.C.
REINFORCED
CONCRETE SLAB
1' - 6" MIN
DRIP FLASHING
BELOW DECKING AT
LOW END AND ABOVE
DECKING AT HIGH
END
FULL HEIGHT C6x10.5
W/ 3 1/2"x12" ANCHOR
BOLT TO CMU
STEEL ANGLE
GATE FRAME
GROUT CELLS
AT REBAR
HEAVY DUTY GATE
HINGE, (3) PER
GATE LEAF
NOTE: GRIND SMOOTH AND
PAINT ALL GATE WELDS
STEEL
CORRUGATED DECK
PL 3/8x6x6 AT HSS
COLUMN ABOVE
1" 1"
(2) 4" DEEP a24
EMBED STUDS
PER PLATE
3" 3"
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:30:27 AM
C:\Users\enavarro\Documents\_RevitLocal\2321 24_0903 Shelter Expansion_R21_enavarroQT4G7.rvt 2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
TRASH
ENCLOSURE
A-604
EN, KS, JL
AS
09/24/24
A-604 3/8" = 1'-0" 1 TRASH ENCLOSURE PLAN
GENERAL NOTES
KEYNOTES
0 2' 4' 6'
3/8" = 1'-0"A-604 3 TRASH ENCLOSURE - SIDE ELEVATION
A-604 3/8" = 1'-0" 2 TRASH ENCLOSURE - BACK ELEVATION
3/8" = 1'-0"A-604 4 TRASH ENCLOSURE - FRONT ELEVATION
A-604 3/4" = 1'-0" 5 TRASH ENCLOSURE - WALL SECTION
A-604 3" = 1'-0" 6 TRASH ENCLOSURE GATE POST
1 1/2" / 1'-0"
8' - 0"
8' - 0"
7' - 9"
8' - 0" 8' - 0"
8' - 0"
1 1/2" / 1'-0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
8' - 0"
EQ EQ
1 1/2" / 1'-0"
EQ EQ
E
Q
E
Q
TYP
EQ
TYP
EQ
T
Y
P
E
Q
T
Y
P
E
Q
EQ EQ
EQ EQ
E
Q
E
Q
1' - 6"
3' - 0"
E
Q
E
Q
12' - 0 1/4"
7' - 2 3/4"
EQ EQ
E
Q
E
Q
3' - 6"
EQ EQ
8' - 0" 4' - 0"8' - 0" 4' - 0"
6' - 6"
6' - 8 1/2"
8' - 6"
8' - 6"
8' - 6"
8' - 6"
EQ EQ
E
Q
E
Q
E
Q
E
Q
10' - 0"
POTENTIAL EXISTING
ROOF DEMO TO BE
COORDINATED WITH
FIRE MARSHAL
15' - 0" 10' - 0" 10' - 0" 5' - 0"
EQ EQ
E
Q
E
Q
4' - 6" 4' - 6"
4' - 0" 6' - 0"
FIBER CEMENT
PANEL SOFFIT
ALIGN SOFFIT JOINTS
WITH WALL JOINTS
SOFFIT VENT STRIPS,
SEE ROOF PLAN
RANGE HOOD BELOW
LAUNDRY
114
STORAGE LINEN
115
UTILITY /
STORAGE
117
MEN'S
BATHROOM
118
COMMERCIAL
KITCHEN
119 FIRE
122
ELECTRICAL
123
CASE
MANAGEMENT
112
CASE
MANAGEMENT
111
DATA
110
ADMINISTRATION
OFFICE
109 INTAKE
102
PEST CONTROL
103
HALLWAY 1
113
WAITING AREA
105
ENTRY
101
WOMEN'S
BATHROOM
148
MEN'S
BATHROOM-NC
147
WOMEN'S
BATHROOM-NC
144
MAINTENANCE
ROOM
146
MECHANICAL
UTILITY
145
COUNSELING
OFFICE 1
143
COUNSELING
OFFICE 2
142
NC-1
140
NC-2
139
NC-3
138
NC-4
137
NC-5
136
NC-6
135
NC-7
134
NC-8
133
NC-9
132
NC-10
131
HALLWAY 3
130
DAY ROOM
141
CLIENT STORAGE
116
OFFICE
107
STAFF
RESTROOM
108
GROUP
COUNSELING
124
WAITING AREA
125
MEDICATION
127
ADMINISTRATION
OFFICE
128
LAUNDRY
129
HALLWAY 4
149
HALLWAY 1
113
HALLWAY 2
126
5' - 0" EQ EQ EQ
E
Q
E
Q
11' - 0" AFF TYP
5' - 0" 5' - 0" E
Q
E
Q
2' - 0" 2' - 0"
3' - 0" EQ EQ 3' - 0"
EA SIDE
3' - 10" TYP
E
Q
E
Q
EQ EQ EQ EQ
E
Q
T
Y
P
E
Q
T
Y
P
4' - 0" 9' - 6" 2' - 6"
2' - 6"
2' - 6"
2' - 6" 2' - 10"
1' - 6"
TYP
EQ
TYP
EQ
T
Y
P
E
Q
T
Y
P
E
Q
E
Q
E
Q
5' - 6"
3' - 6" 3' - 0"
4' - 0" EQ EQ EQ EQ 5' - 1 1/2" 9' - 8 3/8" EQ EQ EQ 2' - 0" 2' - 0"
2' - 6"
2' - 5" 2' - 6" E
Q
E
Q
E
Q
E
Q
E
Q
2' - 0" 2' - 6"
EQ EQ EQ EQ
E
Q
E
Q
EQ EQ
2' - 0" EQ EQ
1' - 6" 1' - 6"
EQ EQ
6' - 4"
2' - 0"
4' - 6"
4' - 0" EQ EQ 4' - 0"
E
Q
E
Q
8' - 0" 8' - 0"
5' - 0" 12' - 0" 12' - 0" 12' - 0"
6' - 0" 6' - 0" E
Q
E
Q
E
Q
E
Q
7' - 6"
8' - 2"
7' - 6"
8' - 0" 8' - 0" 2' - 0" 6' - 0"
11 3/4"
4' - 0"
COOLING
UNIT LID
5' - 0"
ROOF STEP ABOVE,
SEE STRUCTURAL
NON-COMBUSTIBLE
FABRIC CANOPY
ABOVE -TYP
RESTROOM
119C
OFFICE
119B
PANTRY
119E
FREEZER
119G
REFRIGERATOR
119F
SEE FOOD SERVICE
DRAWINGS FOR
LIGHTING IN
COOLING UNITS
8' - 0"
TYP
7' - 8"
TYP
2' - 0"
8' - 0"
8' - 0"
7' - 6"
4' - 2
4' - 6"
"
4' - 0"
6' - 0" 6' - 0"
E
Q
E
Q
E
Q
E
Q
8' - 0" 8' - 0"
8' - 0"
6' - 0"
EQ EQ
6' - 0"
EQ EQ
6' - 0"
E
Q
E
Q
8' - 0"
8' - 0"
8' - 0"
9' - 0" 9' - 0"
8' - 0" 3' - 0"
10' - 0"
6' - 0" 10' - 0"
3' - 0"
10' - 0"
10' - 0"
8' - 0"
9' - 0"
3' - 0"3' - 0"
8' - 0"8' - 0"
4' - 0"
2' - 0"
4' - 0"
6' - 0"
1' - 9" 1' - 9"
1' - 2" 1' - 2"
6.18 9' - 0"
AFF
PRE-MANUFACTURED
WOOD SLAT CEILING
3' - 6"
4' - 6"
1' - 3"
2' - 3"
1' - 8"
7' - 6"
E
Q
E
Q
3' - 0" 3' - 0"
3' - 0"
3' - 0"
E
Q
E
Q
8' - 10 3/4"
2' - 0"
WALL MOUNTED
ROLL UP DOOR
PER SPECS
1. SEE A850 FOR STANDARD ACCESSIBILITY
REQUIREMENTS.
2. ALL DIMENSIONS ARE TO FACE OF FINISH UNO.
3. SEE A851 FOR PENETRATION REQUIREMENTS.
4. SEE A850 FOR ACCESSIBLE FIXTURE AND ACCESSORY
MOUNTING HEIGHTS, BLOCKING AND CLEARANCES.
5. SEE ELECTRICAL PLANS FOR EMERGENCY EGRESS
LIGHTING.
6. CENTER LIGHT FIXTURES IN ROOM IF NO DIMENSIONS
ARE PROVIDED. NOTIFY THE ARCHITECT IF THERE
APPEARS TO BE A CONFLICT.
DROPPED GYPSUM SOFFIT / CEILING
RECESSED CAN LIGHT, SEE ELECTRICAL
WALL SCONCE LIGHT, SEE ELECTRICAL
LINEAR PENDANT LIGHT, SEE ELECTRICAL
RECTANGULAR SURFACE MOUNT
LIGHT, SEE ELECTRICAL
PENDANT CAN LIGHT, SEE ELECTRICAL
RECTANGULAR RECESSED LIGHT,
SEE ELECTRICAL
DIFFUSER GRILLE, SEE MECHANICAL
SECURITY CAMERA, SEE TECHNOLOGY
ATTIC / ROOF ACCESS HATCH
SOLAR TUBE REFLECTOR
DIRECT/INDIRECT PENDANT
RECESSED CAN LIGHT
SURFACE MOUNTED CAN LIGHT
DROPPED 24"x24" ACT SOFFIT / CEILING
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 1:0
5:24
P
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
OVERALL CEILING
PLAN
A-701
EN, KS, JL
AS
07/25/24
A-701 3/16" = 1'-0"
1 OVERALL CEILING PLAN
GENERAL NOTES
LEGEND
N
0 4' 8' 12'
REINFORCED
CONCRETE SLAB,
SEE STRUCTURAL
FLOOR FINISH,
SEE PLANS FOR
TYPE AND
LOCATION
15mil VAPOR
BARRIER
COMPACTED
ROCK BASE, SEE
GEOTECH
REPORT
UNDISTURBED
SOIL
ROOF MEMBRANE
PROTECTION BOARD R-12 MIN CONTINUOUS
RIGID INSULATION
VAPOR RETARDER
ROOF
SHEATHING, SEE
STRUCTURAL
DRAFTSTOP
WHERE NOTED
ON ROOF PLAN
ROOF TRUSS,
SEE STRUCTURAL
(2) LAYERS TYPE
'X' GYPSUM
BOARD APPLIED
PERPENDICULAR
TO TRUSSES
MIN OFFSET
8"
R-19 MIN BATT
INSULATION
1 3/4" METAL
SUSPENSION
SYSTEM
(1) LAYER 1/2" MIN
GYPSUM BOARD / ACT
SYSTEM, SEE RCP
1 3/4"
SEE FOR SEISMIC
BRACING REQUIREMENTS 4 / A-853
2x6 WOOD STUDS
AT 16" OC, SEE
STRUCTURAL
3 1/2" BATT
INSULATION AT
BATHROOM ,
MEETING AND
OFFICE WALLS
(1) LAYER 5/8"
TYPE 'X' GYPSUM
BOARD
(1) LAYER 5/8"
TYPE 'X' GYPSUM
BOARD
5B 2x4 WOOD STUDS AT 16" OC IN LIEU OF 2x6 WOOD STUDS
2x6 WOOD STUDS
AT 16" OC, SEE
STRUCTURAL
5/8" TYPE 'X'
GYPSUM BOARD
6B 2x4 WOOD STUDS AT 16" OC IN LIEU OF 2x6 WOOD STUDS
R-17 MIN BATT INSLUATION
2x6 WOOD STUDS AT 16"
OC, SEE STRUCTURAL
5/8" TYPE 'X'
GYPSUM BOARD
SHEATHING, SEE
STRUCTURAL
DRAINABLE WRB
FIBER CEMENT PANEL
SIDING; SEE ELEVATIONS
INTERIOR EXTERIOR
METAL JOINT FINISHED TO
MATCH SIDING OVER WRB PRESTRIP AS REQUIRED BY MFR
UNIT CORRIDOR
(1) LAYER 5/8"
TYPE 'X' GYPSUM
BOARD
WOOD
SHEATHING
WHERE OCCURS,
SEE STRUCTURAL
3 1/2" BATT
INSULATION
2x6 WOOD STUDS
AT 16" OC, SEE
STRUCTURAL
RESILIENT
CHANNELS AT 24"
OC
(1) LAYER 5/8"
TYPE 'X' GYPSUM
BOARD
GRID
7B 2x4 WOOD STUDS AT 16" OC IN LIEU OF 2x6 WOOD STUDS
2x6 WOOD STUDS
AT 16" OC, SEE
STRUCTURAL
3 1/2" BATT
INSULATION AT
BATHROOM AND
OFFICE WALLS
(1) LAYER 5/8"
TYPE 'X' GYPSUM
BOARD
(1) LAYER 5/8"
TYPE 'X' GYPSUM
BOARD
WOOD
SHEATHING
WHERE OCCURS,
SEE STRUCTURAL
8B 2x4 WOOD STUDS AT 16" OC IN LIEU OF 2x6 WOOD STUDS
UNIT UNIT/CORRIDOR
(1) LAYER 5/8"
TYPE 'X' GYPSUM
BOARD
WOOD
SHEATHING
WHERE OCCURS,
SEE STRUCTURAL
3 1/2" ACOUSTIC
FIBERGLASS BATT
INSULATION
1" AIR SPACE
2x4 WOOD STUDS
AT 24" OC MAX
UNO, SEE
STRUCTURAL
(1) LAYER 5/8"
TYPE 'X' GYPSUM
BOARD
GRID
SEE STRUCTURAL
FOR PIPE
PENETRATION
LIMITATIONS
R-17 MIN BATT INSLUATION
2x6 WOOD STUDS AT 16"
OC, SEE STRUCTURAL
5/8" TYPE 'X'
GYPSUM BOARD
SHEATHING, SEE
STRUCTURAL
DRAINABLE WRB
FIBER CEMENT LAP SIDING;
SEE ELEVATIONS
INTERIOR EXTERIOR
8 X 8 X 16 CMU,
SEE STRUCTURAL
REINFORCEMENT
AS NEEDED, SEE
STRUCTURAL
ELASTOMERIC PAINT
PER ELEVATION
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:30:30 AM
C:\Users\enavarro\Documents\_RevitLocal\2321 24_0903 Shelter Expansion_R21_enavarroQT4G7.rvt 2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
ASSEMBLIES
A-801
EN, KS, JL
AS
01/03/19
1. WHERE A NON-SHEARWALL EXTENDS AND ALIGNS
PARALLEL WITH A SHEAR WALL, PROVIDE ADDITIONAL
SHEATHING LAYERS TO THE NONSHEAR WALL TO
PROVIDE CONTINUOUS FACE OF FINISH.
2. LOCATE THERMAL INSULATION ON THE COLD SIDE (IN
WINTER) OF DOMESTIC WATER PIPES AS REQUIRED TO
PROTECT PIPE FROM FREEZING.
3. PROVIDE ADDITIONAL FRAMING, BLOCKING, AND FINISHES
AS REQUIRED FOR PLUMBING ACCESS PANELS.
4. PROVIDE ADDITIONAL BLOCKING AS REQUIRED TO
SUPPORT SHELVING, TOWEL BARS, GRAB BARS, RAILINGS,
AND ALL OTHER WALL-MOUNTED ACCESSORIES AND
EQUIPMENT.
5. PROVIDE UL APPROVED THROUGH PENETRATION AND
MEMBRANE PENETRATION FIRESTOP SYSTEMS AS
REQUIRED BY CODE AT ALL ELECTRICAL, PLUMBING, AND
MECHANICAL PENETRATIONS IN FIRE-RATED ASSEMBLIES,
SEE XX/XX.
6. PROVIDE WATER RESISTANT GYPSUM BOARD AT BATH TUB
AND SHOWER WALLS.
7. PROVIDE FIRE BLOCKING & DRAFTSTOPS IN CONCEALED
SPACES BETWEEN RATED ASSEMBLIES, PROVIDE FIRE
BLOCKS AND DRAFT STOPS PER 2014 OSSC SECTION 718.
8. PROVIDE FIRE BLOCKING IN CONCEALED SPACES OF
WALLS, PARTITIONS, AND FURRED SPACES AT 10 FT OC
MIN IN BOTH VERTICAL AND HORIZONTAL DIRECTIONS
AND AT ALL INTERCONNECTIONS BETWEEN CONCEALED
VERTICAL AND HORIZONTAL SPACES.
9. PROVIDE FLUID APPLIED WATERPROOFING AT EXTERIOR
FOUNDATIONS, FOOTINGS AND SUBGRADE WALLS.
BLIND-SIDE ATTACHED BENTONITE WATERPROOFING TO
BE USED AT SHORED WALLS.
FLOOR - SLAB ON GRADE
1 ASSEMBLY: N/A
1HR FLAT ROOF/CEILING
2 ASSEMBLY: GA RC 2602 FIRE: 1HR
NON-RATED DROPPED CEILING
3 ASSEMBLY: N/A
NON-RATED INTERIOR WALL
5A
ASSEMBLY: N/A
NON-RATED INTERIOR FURRING WALL
6A
ASSEMBLY: N/A
1HR EXTERIOR WALL - PANEL
10 ASSEMBLY: WS4-1.2 FIRE: 1HR
1HR CORRIDOR WALL
7A
ASSEMBLY: GA WP 3243 FIRE: 1HR
SOUND: STC 51SOUND TEST NRC-TL-97-003
1HR INTERIOR WALL
8A
ASSEMBLY: GA WP 3510 FIRE: 1HR
1HR PARTY WALL
9 ASSEMBLY: UL U431 FIRE: 1HR
SOUND: STC 56-57TL-93-266 OR PGD-02-10-055
1HR EXTERIOR WALL - LAP
11 ASSEMBLY: WS4-1.2 FIRE: 1HR
2HR EXTERIOR WALL - CMU
12 ASSEMBLY: CBC TABLE 721.1(2) ITEM 3 FIRE: 2HR
A.
SINGLE FLUSH
B.
SINGLE FLUSH
NARROW LITE
C.
SINGLE FLUSH
FULL LITE
E.
SINGLE FLUSH
LOUVRE
F.
DOUBLE FLUSH
D.
SINGLE FLUSH
HALF LITE
G.
SLIDING POCKET
H.
DOUBLE FLUSH
FULL LITE
A.1.
SINGLE FLUSH
PARTIAL
W1) FIXED
EXTERIOR
W4) FIXED / AWNING
EXTERIOR
W3) SINGLE HUNG
EXTERIOR
1' - 4" 2' - 6"
5' - 6"5' - 6"
U
N
O
2' - 3"
U
N
O
2' - 3"
W2) FIXED
EXTERIOR
CLERESTORY
VA
RIE
S
4' - 2" W6) FIXED
INTERIOR
3' - 0"
U
N
O
2' - 3" 7' - 7"
5' - 6"
3' - 0"
W5) FIXED
EXTERIOR
T
O
T.O. PLA
T
E
4' - 0" 3' - 0"
3' - 0"
FINISHED FLOOR
U
N
O
2' - 3" 5' - 6"
3' - 0"
W7) (E) SINGLE HUNG
EXTERIOR
5' - 6"
3' - 0"
E
XIS
TIN
G
M
A
T
C
H
W8) FIXED
INTERIOR
VA
RIE
S
4' - 2"
5' - 0"
1' - 7"
5' - 10"
8' - 10"
1' - 7"
8' - 10"
9' - 10 1/4"
EQ EQ
1' - 7"
9' - 7"
5' - 10 1/4"
2' - 6"
4' - 8"
6' - 0"
1' - 5"
EQ EQ EQEQ
OPERABLE
SLIDER
WINDOW
7' - 6"
5' - 0"
1' - 7"
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:3
3 A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
SCHEDULES
A-811
EN, KS, JL
AS
01/03/19
DOOR SCHEDULE
DOOR
NUMBER ROOM NAME WIDTH
HEIGH
T
THICKNES
S TYPE
DOOR FRAME
HARDWARE
FIRE
RATING
SIGN TYPE
(SEE A-851) COMMENTSMATERIAL FINISH MATERIAL FINISH
101A ENTRY 6' - 0" 7' - 4" 0' - 1 3/4" SF ALUM CLR ALUM CLR 1 102 INTAKE 3' - 0" 7' - 0" 0' - 1 3/4" B HM PT HM PT 16 20 MIN S1 103 PEST CONTROL 3' - 0" 7' - 0" 0' - 1 3/4" B HM PT HM PT 16 20 MIN S1 104 WAITING AREA 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 14 20 MIN S1 106A ENTRY 3' - 0" 7' - 4" 0' - 1 3/4" SF ALUM CLR ALUM CLR 5 107 OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" C WD CLR WD CLR 16 20 MIN S1 108 STAFF RESTROOM 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 18 20 MIN S2 109A ADMINISTRATION OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" C WD CLR WD CLR 16 20 MIN S1 109B CASE MANAGEMENT 3' - 0" 6' - 8" 0' - 1 3/8" G WD CLR WD CLR 20 S1 110 DATA 3' - 0" 7' - 4" 0' - 1 3/4" E WD CLR WD CLR 16 20 MIN S1 111A CASE MANAGEMENT 3' - 0" 7' - 0" 0' - 1 3/4" C WD CLR WD CLR 19 20 MIN S1 111B CASE MANAGEMENT 3' - 0" 6' - 8" 0' - 1 3/8" G WD CLR WD CLR 20 S1 112 CASE MANAGEMENT 3' - 0" 7' - 0" 0' - 1 3/4" C WD CLR WD CLR 19 20 MIN S1 114A LAUNDRY 3' - 0" 7' - 0" 0' - 1 3/4" D WD CLR WD CLR 12 20 MIN S1 115A STORAGE LINEN 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 16 S1 116A STORAGE 6' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 17 20 MIN S1 117 STORAGE CLIENT ITEMS 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 16 20 MIN S1 118A MENS BATHROOM 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 11 20 MIN S2 119A COMMERCIAL KITCHEN 6' - 0" 7' - 0" 0' - 1 3/4" A WD CLR WD CLR 9 20 MIN S1 119B COMMERCIAL KITCHEN 3' - 0" 7' - 0" 0' - 1 3/4" C HM PT HM PT 16 S1 119C RESTROOM 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT PT HM 18 S2 119D COMMERCIAL KITCHEN 4' - 0" 7' - 4" 0' - 1 3/4" A HM PT HM PT 6 S1 119E COMMERCIAL KITCHEN 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 22 S1 122A FIRE RISER 3' - 0" 7' - 4" 0' - 1 3/4" A HM PT HM PT 2 S1 123A ELECTRICAL 3' - 0" 7' - 4" 0' - 1 3/4" A HM PT HM PT 2 60 MIN S1 124A GROUP COUNSELING 3' - 0" 7' - 0" 0' - 1 3/4" C WD CLR WD CLR 16 20 MIN S1 124B GROUP COUNSELING 3' - 0" 7' - 0" 0' - 1 3/4" C WD CLR WD CLR 16 20 MIN S1 127 MEDICATION STORAGE 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 16 S1 128A ADMINISTRATION OFFICE 3' - 0" 7' - 0" 0' - 1 3/4" C WD CLR WD CLR 16 20 MIN S1 129 LAUNDRY 3' - 0" 7' - 0" 0' - 1 3/4" D WD CLR WD CLR 13 20 MIN S1 130A ENTRY 3' - 0" 7' - 4" 0' - 1 3/4" SF ALUM CLR ALUM CLR 3 131 NON-CONGREGATE 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 20 MIN S1 132 NON-CONGREGATE 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 20 MIN S1 133 NON-CONGREGATE 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 20 MIN S1 134 NON-CONGREGATE 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 20 MIN S1 135 NON-CONGREGATE 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 20 MIN S1 136 NON-CONGREGATE 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 20 MIN S1 137 NON-CONGREGATE 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 20 MIN S1 138 NON-CONGREGATE 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 20 MIN S1 139 NON-CONGREGATE 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 20 MIN S1 140 NON-CONGREGATE 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 20 MIN S1 142A COUNSELING OFFICE 2 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 19 20 MIN S1 142B COUNSELING OFFICE 2 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 19 20 MIN S1 143A COUNSELING OFFICE 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 19 20 MIN S1 143B COUNSELING OFFICE 1 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 19 20 MIN S1 144A WOMENS BATHROOM 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 11 20 MIN S2 144B SHOWER ROOM 3' - 0" 7' - 0" 0' - 1 3/4" A.1 HM PT HM PT 11 S1 145 STORAGE 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 15 20 MIN S1 146 MAINTENANCE 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 15 20 MIN S1 147A MENS BATHROOM 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 11 20 MIN S2 147B SHOWER ROOM 3' - 0" 7' - 0" 0' - 1 3/4" A.1 HM PT HM PT 11 S1 148A HALLWAY 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 11 S2 149A ENTRY 3' - 0" 7' - 0" 0' - 1 3/4" C ALUM CLR ALUM CLR 1.1 S1 149B ENTRY 3' - 0" 7' - 4" 0' - 1 3/4" SF ALUM CLR ALUM CLR 3.1 149C ENTRY 3' - 0" 7' - 4" 0' - 1 3/4" C HM PT PT HM 7 S1 149D ENTRY 3' - 0" 7' - 4" 0' - 1 3/4" C HM PT HM PT 7 S1 149E ENTRY 3' - 0" 7' - 0" 0' - 1 3/4" B HM PT HM PT 21 20 MIN S1 G1 SITE 5' - 0" 4' - 0" 0' - 1 1/2" - HM MATCH
FENCE
MTL MATCH
FENCE
GATE PANIC HARDWARE
G2 SITE 5' - 0" 4' - 0" 0' - 1 1/2" - HM MATCH
FENCE
MTL MATCH
FENCE
GATE
G3 SITE 5' - 0" 4' - 0" 0' - 1 1/2" - HM MATCH
FENCE
MTL MATCH
FENCE
GATE PANIC HARDWARE
X102 (E) BLDG 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 5 S1 X103 (E) BLDG 3' - 0" 7' - 0" 0' - 1 3/4" A HM PT HM PT 5 S1 X104 (E) BLDG 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 S1 X105 (E) BLDG 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 S1 X106 (E) BLDG 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 S1 X107 (E) BLDG 3' - 0" 7' - 0" 0' - 1 3/4" B WD CLR WD CLR 10 S1 Y101 (E) BLDG 6' - 0" 7' - 2" 0' - 1 3/4" HM PT HM PT 1 S1
MATERIAL/FINISH
ROOM FINISH SCHEDULE
ROOM NO ROOM NAME FLOOR BASE WALL CEILING COMMENTS AREA 101 ENTRY CONC-1 RB-2 GYP BD/PT GYP BD/PT FOUR PAINT COLORS. 168 SF 102 INTAKE CPT-1 WB-1 GYP BD/PT GYP BD/PT 143 SF
103 PEST CONTROL CONC-1 RB-1 GYP BD/PT GYP BD/PT 122 SF 105 WAITING AREA CONC-1 RB-2 GYP BD/PT GYP BD/PT FOUR PAINT COLORS. 281 SF 106 HALLWAY 5 CONC-1 RB-2 GYP BD/PT GYP BD/PT FOUR PAINT COLORS. 299 SF 107 OFFICE CPT-1 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 105 SF 108 STAFF RESTROOM CONC-1 RB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 81 SF 109 ADMINISTRATION OFFICE CPT-1 WB-1 GYP BD/PT GYP BD/PT 204 SF 110 DATA CONC-1 RB-1 GYP BD/PT GYP BD/PT 60 SF
111 CASE MANAGEMENT CPT-1 WB-1 GYP BD/PT GYP BD/PT 216 SF 112 CASE MANAGEMENT CPT-1 WB-1 GYP BD/PT GYP BD/PT 227 SF 113 HALLWAY 1 CONC-1 RB-2 GYP BD/PT GYP BD/PT FOUR PAINT COLORS. 914 SF 114 LAUNDRY CONC-1 RB-1 GYP BD/PT GYP BD/PT 425 SF
115 STORAGE LINEN CONC-1 RB-1 GYP BD/PT GYP BD/PT 105 SF 116 CLIENT STORAGE CONC-1 RB-1 GYP BD/PT GYP BD/PT 131 SF 117 UTILITY / STORAGE CONC-1 RB-1 GYP BD/PT GYP BD/PT 121 SF 118 MEN'S BATHROOM CONC-1 RB-1 GYP BD/PT GYP BD/PT 650 SF 119 COMMERCIAL KITCHEN CONC-2 RB-1 GYP BD/PT GYP BD/PT 921 SF 119B OFFICE CONC-2 RB-1 GYP BD/PT GYP BD/PT 53 SF
119C RESTROOM CONC-2 RB-1 GYP BD/PT GYP BD/PT 57 SF
119E PANTRY CONC-2 RB-1 GYP BD/PT GYP BD/PT 87 SF
119F REFRIGERATOR CONC-2 RB-1 GYP BD/PT GYP BD/PT 174 SF 119G FREEZER CONC-2 RB-1 GYP BD/PT GYP BD/PT 97 SF
122 FIRE CONC-2 RB-1 GYP BD/PT GYP BD/PT 100 SF
123 ELECTRICAL CONC-1 RB-1 GYP BD/PT GYP BD/PT 100 SF
124 GROUP COUNSELING CPT-3, CPT-4 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 577 SF 125 WAITING AREA CONC-1 RB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 102 SF 126 HALLWAY 2 CONC-1 RB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 126 SF 127 MEDICATION CPT-1 WB-1 GYP BD/PT GYP BD/PT HIGH SECURITY 62 SF 128 ADMINISTRATION OFFICE CPT-1 WB-1 GYP BD/PT GYP BD/PT 131 SF 129 LAUNDRY CONC-1 RB-1 GYP BD/PT GYP BD/PT 87 SF
130 HALLWAY 3 CONC-1 RB-1 GYP BD/PT GYP BD/PT THREE PAINT COLORS. VENEER ACCENT WALL. 598 SF 131 NC-10 CPT-2 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 116 SF 132 NC-9 CPT-2 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 115 SF 133 NC-8 CPT-2 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 115 SF 134 NC-7 CPT-2 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 115 SF 135 NC-6 CPT-2 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 115 SF 136 NC-5 CPT-2 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 115 SF 137 NC-4 CPT-2 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 115 SF 138 NC-3 CPT-2 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 115 SF 139 NC-2 CPT-2 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 115 SF 140 NC-1 CPT-2 WB-1 GYP BD/PT GYP BD/PT TWO PAINT COLORS. 113 SF 141 DAY ROOM CONC-1, CPT-3 RB-1 GYP BD/PT GYP BD/PT THREE PAINT COLORS. VENEER ACCENT WALL. 440 SF 142 COUNSELING OFFICE 2 CPT-1 WB-1 GYP BD/PT GYP BD/PT 104 SF 143 COUNSELING OFFICE 1 CPT-1 WB-1 GYP BD/PT GYP BD/PT 104 SF 144 WOMEN'S BATHROOM-NC CONC-1 RB-1 GYP BD/PT GYP BD/PT 238 SF 145 MECHANICAL UTILITY CONC-1 RB-1 GYP BD/PT GYP BD/PT 80 SF 146 MAINTENANCE ROOM CONC-1 RB-1 GYP BD/PT GYP BD/PT 78 SF 147 MEN'S BATHROOM-NC CONC-1 RB-1 GYP BD/PT GYP BD/PT 237 SF 148 WOMEN'S BATHROOM CONC-1 RB-1 GYP BD/PT GYP BD/PT 410 SF 149 HALLWAY 4 CONC-1 RB-2 GYP BD/PT GYP BD/PT 241 SF
151 NC-14 CPT-2 WB-1 GYP BD/PT GYP BD/PT (E) BLDG, TWO PAINT COLORS. 142 SF 152 NC-13 CPT-2 WB-1 GYP BD/PT GYP BD/PT (E) BLDG, TWO PAINT COLORS. 142 SF 153 NC-12 CPT-2 WB-1 GYP BD/PT GYP BD/PT (E) BLDG, TWO PAINT COLORS. 144 SF 154 NC-11 CPT-2 WB-1 GYP BD/PT GYP BD/PT (E) BLDG, TWO PAINT COLORS. 144 SF 1/4" = 1'-0"
DOOR TYPES
1/4" = 1'-0"
WINDOW TYPES
A-811 1/4" = 1'-0"
1 STOREFRONT 1
A-811 1/4" = 1'-0"
2 STOREFRONT 2
A-811 1/4" = 1'-0"
3 STOREFRONT 3
A-811 1/4" = 1'-0"
4 STOREFRONT 4
A-811 1/4" = 1'-0"
5 STOREFRONT 5
CUT HEAD FLAP AND SECURE IT
AWAY FROM OPENING
INSTALL WRB IN SHINGLE
LAPPED STYLE, SEAL WITH WRB
MANUFACTURER'S APPROVED
TAPE. WRAP WRB INTO JAMBS
OF WINDOW OPENING
NOTE: VERIFY OPENING WILL
ENABLE MANUFACTURER'S
REQUIRED CLEARANCE AT HEAD
AND JAMBS OF WINDOWS. IF
CLEARANCES ARE NOT AVAILABLE
NOTIFY ARCHITECT.
STEP 1 STEP 2
SECURE WINDOW TO FRAMED
OPENING BY APPLYING
SEALANT ONTO BACK SIDE OF
HEAD AND JAMB FLANGE PER
WINDOW MANUFACTURER'S
RECOMMENDATIONS
PROVIDE SEALANT DAM
IMMEDIATELY BEHIND
WINDOW AT BACKER
ANGLE AND UP JAMBS 1"
AFTER WINDOW
INSTALLATION. TIE
SEALANT TO AIR SEAL AT
JAMBS.
STEP 7 STEP 8
INSTALL HEAD
FLASHING FIRST
INSTALL 6" SAM AT HEAD
OVER SAM AT JAMB FLANGE
AND OVER HEAD FLASHING,
SAM SHALL BE ROLLED DOWN
INSTALL DRAINAGE MAT
BEHIND SILL FLANGE FOR
WIDTH TO SEAL
9"
9"
45°
9"
INSTALL BACKER ANGLE AT
B.O .OPENING WITH
ENOUGH SPACE FOR
INSTALLATION OF WINDOW
AND SEALANT JOINT
INSTALL WRB AND WRAP INTO
HEAD AND JAMB AND SECURE
IT AWAY FROM OPENING
18"
STEP 3
INSTALL SAM IN WINDOW SILL,
EXTEND UP JAMBS 6" ON EA
SIDE OVER WRB, PRESS SAM
ALONG FRONT OF SILL AND INTO
CORNERS USING ROLLER TO
ROLL IT DOWN FIRMLY FOR
GOOD ADHESION, THEN INSTALL
CORNER BOOT
TAPE WITH BOW TIE SHAPED
SAM AT CORNER
3. SAM BOW TIE
1. SILL SAM
2. CORNER BOOT
INSTALL ORDER:
STEP 4
STEP 5
INSTALL 6" SIDE SAM ON EA SIDE OF
JAMB OVER WRB AND WINDOW
FLANGE, SAM SHALL BE ROLLED DOWN
NOTES:
• INSPECT WINDOW FRAME MITER
JOINTS AND NAILING FLANGES
FOR DAMAGE
• AFTER WINDOW IS PLACED INTO
ROUGH OPENING, ADJUST TO
ENABLE MANUFACTURER'S
MINIMUM AIRSPACE BETWEEN
WINDOW AND JAMBS/HEAD
• INSTALL WINDOW PER MFR'S
INSTRUCTIONS, CLEAN WINDOW
SEALANT OFF BUILDING
SUBSTRATE, WRB AND WINDOW
FIN, DO NOT INSTALL SAMF UNTIL
WINDOW SEALANT HAS CURED
• DO NOT SECURE WINDOW
THROUGH NAIL FIN AT HEAD OF
WINDOW UNLESS APPROVED BY
WINDOW MRF
• FASTEN USING PREPUNCHED
HOLES IN FLANGES ONLY
STEP 6
SEAL AND LOWER HEAD FLAP OF
WRB OVER 6" SAM
TAPE THE 45 DEGREE
CUTS WITH WRB TAPE.
VERIFY IF SEALANT NEEDS
TO DRY FIRST WITH MFR
NOTE:
• BLADE OFF AND CLEAN
WINDOW FLANGES SO
THEY ARE FREE OF
DEBRIS FOR STEP 5
ALTERNATE: SINGLE PIECE
FLEXIBLE FLASHING IN LIEU OF
BOW TIE AND CORNER BOOT
SAM LAPPED
OVER WRB AND
WRAPPED INTO
WINDOW
OPENING AND
UPTURNED AT
BACKER ANGLE
SHIM FOR
TRIM AS
REQUIRED
METAL BACKER
ANGLE, 1" x 1" WOOD TRIM
AIR SEAL
WINDOW SHIM
WINDOW PER
SCHEDULE
NO SEALANT
AT BOTTOM
FLANGE
DRAINAGE MAT
CONNECT AIR
SEAL TO
FLANGE AT
JAMB BEYOND
SEAL WINDOW
TO TRIM
2" MIN 2"
SEE
SECTIONS
INTERIOR SEAL
SIDING TRIM
WINDOW PER
SCHEDULE
SEALANT
SAM
AIR SEAL
2" 2" MIN
SEAL WINDOW
TO TRIM
CONNECT AIR
SEAL TO SEAL
AT BACKER
ANGLE AT SILL
BELOW
SAM WRAPPED
INTO OPENING
SIDING TRIM
SAM
WRAPPED
INTO
WINDOW
OPENING
AIR SEAL
SAM
WINDOW PER
SCHEDULE
NO SEALANT
2" MIN 2" MIN
SEALANT
METAL FLASHING
FINISHED TO
MATCH SIDING
SEE
SECTIONS
WRB SEALED
TO SAM
SIDING PER
ELEVATIONS
CONNECT AIR
SEAL TO
FLANGE AT
JAMB BEYOND
2" MIN
FOUNDATION
DAMP PROOFING
SAM
DRAINAGE MAT
STAINLESS STEEL
PAN FLASHING
SEALANT AND
BACKER ROD
WALL
BEYOND
SHIM ABOVE AND
BELOW FLASHING
+/- 1"
STOREFRONT
PER SCHEDULE
2"x2"
BACKER
ANGLE
FASTENER
GRADE SLOPED
AWAY FROM
BUILDING
AIR SEAL
SEAL CLOSURE
TO TRIM
SIDING TRIM
STOREFRONT
PER SCHEDULE
AIR SEAL
SAM WRAPPED
INTO OPENING
METAL CLOSURE FINISHED
TO MATCH STOREFRONT
MULLIONS SET IN SEALANT
SHIM PER MFR
WRB SEALED
TO SAM
J-TRIM
AIR SEAL
SAM
NO SEALANT
SEALANT
SEE
SECTIONS
WRB SEALED
TO SAM
SIDING PER
ELEVATIONS
STOREFRONT
PER SCHEDULE
AIR SEAL
SAM WRAPPED
INTO OPENING
METAL FLASHING
AND COUNTER
FLASHING
FINISHED TO
MATCH MULLIONS
SEALANT AND
BACKER ROD
2" MIN 2" MIN
J-TRIM
STOREFRONT
PER SCHEDULE
AIR SEAL
SAM
SEALANT AND
BACKER ROD
1x2
MDF
TRIM
WRB
2" MIN
CLADDING PER RCP
NO SEALANT
1/4"
SAM
WRAPPED
INTO
WINDOW
OPENING
AIR SEAL
SAM
WINDOW PER
SCHEDULE
NO SEALANT
2" MIN 2" MIN
SEALANT
METAL
FLASHING AND
COUNTER
FLASHING
SEE
SECTIONS
WRB SEALED
TO SAM
SIDING PER
ELEVATIONS
FIBER CEMENT
TRIM
TRIM FLASHING
1"
BLOCKING AS
REQUIRED
CONNECT AIR
SEAL TO
FLANGE AT
JAMB BEYOND
WINDOW PER
SCHEDULE
SEALANT
SAM
AIR SEAL
2" 2" MIN
SEAL WINDOW
TO TRIM
CONNECT
FLANGE
WEATHER SEAL
TO SEAL AT
BACKER ANGLE
AT SILL BELOW
SAM WRAPPED
INTO OPENING
TRIM PER ELEVATION
1/4" 1/4" 1"
BLOCKING AS
REQUIRED
METAL FIN TRIM
SAM LAPPED OVER
WRB AND WRAPPED
INTO WINDOW
OPENING AND
UPTURNED AT
BACKER ANGLE SHIM FOR
TRIM AS
REQUIRED
METAL BACKER
ANGLE, 1" x 1" WOOD TRIM
WEATHER SEAL
WINDOW SHIM
WINDOW PER
SCHEDULE
NO SEALANT AT
BOTTOM FLANGE
DRAINAGE MAT
CONNECT WEATHER
SEAL TO FLANGE AT
JAMB BEYOND
SEAL WINDOW
TO TRIM
2" MIN 2"
SEE
SECTIONS
VAPOR
RETARDER
INTERIOR SEAL
FIBER CEMENT
TRIM
SIDING PER
ELEVATIONS
METAL FIN TRIM
1"
BLOCKING AS
REQUIRED
SEE FOR 14 / A-821
TYPICAL DETAILING
FILLET SEAL
SIDING TO
REVEAL
METAL JOINT
CHANNEL
SEAL TRIM
TO CHANNEL
SAM
METAL PAN
FLASHING
FINISHED TO
MATCH
STOREFRONT
SEALANT AND
BACKER ROD
WALL BEYOND
SHIM ABOVE
AND BELOW
FLASHING
STOREFRONT
PER SCHEDULE
SEE
SECTIONS
1"
AIR SEAL
J-TRIM
S.S. SHELF
FOR ROLL UP
DOOR
TERMINATION
VRFY W/ MFR
3"
METAL ROOL
UP DOOR IN
CLOSED
POSITION
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:3
5 A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
DETAILS
A-821
EN, KS, JL
AS
01/03/19
1/2" = 1'-0"A-821
1 WINDOW WRAP SEQUENCE (SIM AT DOORS AND LOUVERS)
6" = 1'-0"A-821
9 WINDOW SILL -TYP
6" = 1'-0"A-821
10 WINDOW JAMB -TYP
6" = 1'-0"A-821
11 WINDOW HEAD -TYP
6" = 1'-0"A-821
17 STOREFRONT SILL AT GRADE
6" = 1'-0"A-821
18 STOREFRONT JAMB
6" = 1'-0"A-821
19 STOREFRONT HEAD
6" = 1'-0"A-821
20 STOREFRONT HEAD AT ROOF
6" = 1'-0"A-821
16 WINDOW HEAD AT LAP SIDING
6" = 1'-0"A-821
14 WINDOW JAMB AT LAP SIDING
6" = 1'-0"A-821
13 WINDOW SILL AT LAP SIDING
6" = 1'-0"A-821
15 WINDOW JAMB AT LAP AT CHANNEL
6" = 1'-0"A-821
12 STOREFRONT SILL AT WALL
2" MIN
FOUNDATION
DAMP PROOFING
SAM
DRAINAGE
MAT
FLASHING
FINISHED TO
MATCH SIDING
GRADE SLOPED
AWAY FROM
BUILDING
AIR SEAL
WALL BASE
PER ROOM
SCHEDULE
SILL
GASKET
WRB SEALED
TO SAM
2" MIN 2" MIN
SAM
NO SEALANT
SEE
SECTIONS
6" MIN
SIDING PER
ELEVATIONS
DRAINAGE MAT
S.S. PAN
FLASHING SET
IN SEALANT
EXTERIOR PAVER
SLOPED AWAY
FROM BUILDING
EXPANSION JOINT
SAM
FOUNDATION
DAMP PROOFING
AIR SEAL
1/4" M
AX
1/2" M
AX
2 1
MAX SLOPE
DOOR SWEEP
AIR SEAL
2" MIN
HM FRAME SET
IN EXPANDING
FOAM SEALANT
SEAL FRAME
TO TRIM
WRB WRAPPED
INTO OPENING
HM DOOR PER
SCHEDULE
COMPRESSION
SEAL
2" MIN 2" MIN
SAM
SIDING TRIM
HM FRAME SET
IN EXPANDING
FOAM SEALANT
SEE
SECTIONS
WRB
WRAPPED
INTO
OPENING
HM DOOR PER
SCHEDULE
COMPRESSION
SEAL
2" MIN 2" MIN
SAM
NO SEALANT
WRB LAPPED
SEALED TO SAM
METAL
FLASHING
FINISHED TO
MATCH DOOR
FRAME
SIDING PER
ELEVATIONS
2" MIN
2" MIN 2" M
NO SEALANT IN
SEE
SECTIONS
DRAINAGE MAT
STAINLESS
STEEL FLASHING
EXTERIOR PAVER
SLOPED AWAY
FROM BUILDING
EXPANSION JOINT
SAM
FOUNDATION
DAMP PROOFING
SIDING PER
ELEVATIONS
AIR SEAL
WALL BASE
PER ROOM
SCHEDULE
SILL
FILTER FABRIC GASKET
AND DRAINAGE
MAT, SEE CIVIL
CLEAN, CRUSHED
GRAVEL - NO
FINES; 6" MIN
ABOVE DRAIN, 2"
MIN BELOW DRAIN
12" MAX
4" DIA
PERFORATED
DRAIN PIPE, SEE
CIVIL FOR
CONNECTIONS
CRUSHED
AGGREGATE
BASE
VAPOR
BARRIER
SIM
SEAL EDGE
OF VAPOR
BARRIER TO
CONCRETE
A-822
5 SEE SECTIONS
SAM LAPPED
OVER COLLAR
WRAP
PENETRATING
ITEM WITH
FLEXIBLE
FLASHING
COLLAR SET IN
SEALANT ON ALL
SIDES
NO SEALANT
2" MIN 2" MIN
WRB SEALED TO
SAM BELOW
SEE
SECTIONS
WRB PRE-STRIP
BEHIND COLLAR
WRB PRE-STRIP
BEHIND COLLAR
TRIM FLASHING
NOTE: FOR PENETRATIONS
EXCEEDING 1 1/2"
FIBER CEMENT
SETTING BLOCK
SAM
SIDING TRIM
FOAM AIR SEAL
INTERIOR
SEAL
WRB SEALED TO
SAM; 2" OVERLAP MIN
SAM LAPPED OVER
FLASHING BY 2" MIN
SIDING PER
ELEVATION
CLADDING PER RCP
METAL FLASHING
FINISHED TO
MATCH WALL
SIDING
NO SEALANT
WRB
4" MIN
1"
1/4"
WRB
BRAKE METAL
SIDING PER
ELEVATION
SEE SECTIONS
5/8" TYPE X GYPSUM
BOARD DRAFT STOP /
FIRE BLOCKING
TRUSS BLOCKING
1"
EMBER RESISTANT
SOFFIT VENT
SAM AT
SHEATHING
SEAMS
2" MIN 2" MIN
FOAM AIR SEAL
VAPOR BARRIER
VAPOR BARRIER
SEAM TAPE PER MFR
PIPE PENETRATION
VAPOR BARRIER
SHEET WITH CUT
OPENING FOR
PENETRATION
VAPOR BARRIER TO
PIPE TAPE PER MFR
FOAM WRAP OVER
PIPE AND VAPOR TIE
FOR CONCRETE
EXPANSION AND
CONTRACTION
SEE PLANS
ADVANCED
CORNER
FRAMING
SIDING PER
ELEVATION
SEAL SIDING TO
CORNER TRIM
6" EA LEG
CORNER SAM
BLOCKING - SIZE
AS REQUIRED FOR
RAINSCREEN
FURRING
VAPOR RETARDER
SEE PLANS
ADVANCED
CORNER FRAMING
SIDING PER
ELEVATION
SEAL SIDING
TO TRIM
BRAKE METAL
CORNER TRIM
6" EA LEG
CORNER SAM
BLOCKING - SIZE
AS REQUIRED
SEE PLANS
FILLET SEAL
SIDING TO
REVEAL
LAP SIDING PER
METAL JOINT ELEVATION
CHANNEL
BLOCKING - SIZE
AS REQUIRED FOR
JOINT CHANNELS
1/4"
1/4"
TOP OF SIDEWALK
PAINTED STEEL COLUMN,
SEE STRUCTURAL
PIPE CAP PAINTED
TO MATCH COLUMN
9' - 6"
EYE PLATE, SEE
STRUCTURAL
EYE BOLT ATTACHED
TO CLASS-A FLAME
SPREAD SHADE FABRIC
SEALANT
SAM
2" 2" MIN
SEAL WINDOW
TO TRIM
SAM WRAPPED
INTO OPENING
SIDING TRIM
FLANGED WALL
CAP VENT
PAINTED TO
MATCH SIDING
AIR SEAL
SAM
NO SEALANT
2" MIN 2" MIN
SEALANT
METAL FLASHING
FINISHED TO
MATCH SIDING
SEE
SECTIONS
WRB SEALED
TO SAM
SIDING PER
ELEVATIONS
SAM LAPPED
OVER WRB AND
WRAPPED INTO
OPENING OVER
BACK SHIM
AIR SEAL
SHIM
NO SEALANT
AT BOTTOM
FLANGE
DRAINAGE MAT
2" MIN 2"
FLANGED WALL
CAP VENT
PAINTED TO
MATCH SIDING
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:37 A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
DETAILS
A-822
EN, KS, JL
AS
09/24/20
A-822 6" = 1'-0"
5 WOOD WALL AT GRADE
A-822 6" = 1'-0"
9 DOOR SILL AT GRADE
6" = 1'-0"A-822
10 OUTSWING DOOR JAMB AT WOOD WALL
6" = 1'-0"A-822
11 OUTSWING DOOR HEAD AT WOOD WALL
A-822 6" = 1'-0"
1 WOOD WALL AT SIDEWALK
A-822 3" = 1'-0"
13 FOUNDATION DRAINAGE
A-822 6" = 1'-0"
17 EXTERIOR PENETRATION
3" = 1'-0"A-822
4 SOFFIT AT WALL
3" = 1'-0"A-822
3 EAVE AT WALL
3" = 1'-0"A-822
2 SLAB ON GRADE PENETRATION
3" = 1'-0"A-822
8 INSIDE CORNER FC TO FC
3" = 1'-0"A-822
12 OUTSIDE CORNER FC TO FC
3" = 1'-0"A-822
7 LAP SIDING VERTICAL CHANNEL
3" = 1'-0"A-822
6 SHADE CANOPY ATTACHMENT
6" = 1'-0"A-822
14 WALL CAP JAMB -TYP
6" = 1'-0"A-822
15 WALL CAP SECTION -TYP
TPO COATED
METAL DRIP EDGE
FASCIA FINISHED
TO MATCH FACIA
SHEET METAL BOX GUTTER
FINISHED TO MATCH FASCIA
ROOF MEMBRANE
FIBER CEMENT FACIA
WRB
FASTEN THROUGH
SEALANT BEAD
BLOCKING
EMBER RESISTANT
SOFFIT VENT
TRUSS BLOCKING /
SUBSTRATE
6"
1 /4
"
ATTACH GUTTER
JUST BELOW DRIP
EDGE
S
E
E
C
I
V
I
L
SEE CIVIL
HIGH TEMP SAM
METAL DRIP EDGE
FASCIA FINISHED
TO MATCH FACIA ROOF MEMBRANE 6"
FIBER CEMENT
FACIA
3/4
"
WRB
FASTEN THROUGH
SEALANT BEAD
MEMBRANE
COVER STRIP
PER ROOF MFR
BLOCKING
EMBER RESISTANT
SOFFIT VENT
1 /4
"
TRUSS
BLOCKING /
SUBSTRATE
METAL DRIP EDGE
FASCIA FINISHED
TO MATCH FACIA ROOF MEMBRANE 6"
FIBER CEMENT
FACIA
WRB
FASTEN THROUGH
SEALANT BEAD
MEMBRANE
COVER STRIP
PER ROOF MFR
BLOCKING
1/4"
TRUSS
BLOCKING /
SUBSTRATE
3/4"
ROOF
MEMBRANE
PARAPET FLASHING &
REINFORCEMENT PER
ROOFING MFR
6" MIN
8" MIN
PROVIDE BLOCKING
IF FASTENERES ARE
REQUIRED
2" MIN
VAPOR
RETARDER
ROOF MEMBRANE
HIGH TEMP SAM
WRB
SIDING PER
ELEVATION
METAL FLASHING
FINISHED TO
MATCH CLADDING
WITH CLEAT FOR
STABILITY
12"
1/4"
ROOF MEMBRANE
6"
2" MIN
2" MIN
2" MIN
ANGLED PT
WOOD TOP PLATE
COUNTER
FLASHING LAPPED
OVER ROOF
MEMBRANE
TERMINATION
BAR OVER HIGH
TEMP SAM
ROOF MEMBRANE
SEAL PER ROOFING MFR
PRE-FABRICATED
COUNTER
FLASHING COLLAR
COMPATIBLE MEMBRANE
FLASHING AND
REINFORCEMENT PER
ROOFING MFR
PRE-FABRICATED
FLASHING BOOT
SEALANT ALL AROUND
8" MIN
S.S. DRAWBAND
COMPATIBLE SEALANT
ALL AROUND
4" MIN
ROOF MEMBRANE
SEAL PER ROOFING MFR
COMPATIBLE MEMBRANE
FLASHING AND
REINFORCEMENT PER
ROOFING MFR
PRE-FABRICATED
FLANGED
GOOSENECK
8" MIN
UTILITY LINES
FILL GAPS WITH
EXPANDING SEALANT
MEMBRANE FLASHING &
REINFORCEMENT PER
ROOFING MFR
REMOVABLE STAINLESS
STEEL CURB COUNTER-
FLASHING
FLASHING CLEAT
8" MIN
GLULAM CURB PER
STRUCTURAL
2" MIN
VAPOR RETARDER
S
LO
P
E
FLASHING PER
ROOF MFR
SHEET METAL
SCUPPER SLEEVE
SIDING PER
ELEVATION
SHEET METAL
CONDUCTOR
HEAD
ROOF MEMBRANE
SAM
WRB
2" MIN
OVERFLOW
PER MFR
SEE CIVIL
A-830 4
SEE CIVIL
SAM,
CONTINUOUS
BELOW SADDLE
METAL SADDLE
FLASHING, PLACE
OVER FLEXIBLE
FLASHING AT INSIDE
CORNER, FASTEN TO
TALLER WALL ONLY
FOR DEFLECTION
LAP WEATHER
RESISTIVE
BARRIER OVER
METAL SADDLE
FLASHING
GUARDRAIL /
PARAPET WALL W/
INTEGRAL SLOPE
TO DRAIN
4"
4"
4"
PER
MECH
CODE
306
.5
30"
MIN
CLEAR
3' - 0"
SPACING
6" TOE
OF RUNG
7" CENTER
NOTE: REFER TO SPEC FOR HATCH INSTALLATION.
SEE FOR CURB DETAIL
18" WIDE STEEL LADDER
3/4" DIA. RUNG
LADDER
15 /
A-830
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:30:38 AM
C:\Users\enavarro\Documents\_RevitLocal\2321 24_0903 Shelter Expansion_R21_enavarroQT4G7.rvt 2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
ROOF DETAILS
A-830
EN, KS, JL
AS
xx/xx/xx
A-830 6" = 1'-0" 3 FLAT ROOF AT LOW EAVE
A-830 6" = 1'-0" 2 FLAT ROOF AT HIGH EAVE
A-830 6" = 1'-0" 1 FLAT ROOF AT RAKEA-830 3" = 1'-0" 5 FLAT ROOF AT WALL 3" = 1'-0"A-830 4 FLAT ROOF PARAPET CAP
A-830 3" = 1'-0"
13 FLAT ROOF PENETRATION
A-830 3" = 1'-0"
14 FLAT ROOF LINESET PENETRATION
A-830 3" = 1'-0"
15 FLAT ROOF CURB
1 1/2" = 1'-0"A-830 8 FLAT ROOF AT SCUPPER1 1/2" = 1'-0"A-830 16 SADDLE FLASHING
A-830 1 1/2" = 1'-0" 6 ROOF HATCH
6" MAX 48" MIN 6" MAX CONTROL WALL
6" M
AX
BACK WALL
NOTE: GRAB BARS SHOWN FOR REFERENCE TYPE A/B BATHTUB ONLY, INSTALL BLOCKING ONLY 3 8" MIN
8-10"
3 3-3
6"
24" MAX 24" MIN
MIN
12"
18" MIN
4" MAX 24" MIN
BACK WALL
CONTROL WALL
TYPE A UNIT
LOCATION OF
SHOWER
CONTROLS
TYPE A UNIT
HANDHELD
SHOWER HEAD
W/59" MIN HOSE
LENGTH
HEAD WALL
HEAD WALL
4" MAX BACK WALL
3 3-3
6"
MIN
12"
BLOCKING
2" MIN 2" MIN
3 8" MIN
3 0" M
AX
MIN
6"
TYPICAL BLOCKING HEIGHTS, SEE
FIXTURES ELEVATION FOR EXCEPTIONS
INSTALL
PEDESTAL AS
NECESSARY TO
ACHIEVE 15"
MINIMUM TO
B.O. OPENING
FRONT LOADING WASHER/DRYER
T.O. CONTROLS
LAUNDRY EQUIPMENT
4 8" M
AX
15-3
4"
NOTE: GRAB BARS SHOWN FOR REFERENCE
TYPE A/B WATER CLOSET ONLY, INSTALL BLOCKING ONLY
FLUSH
LEVER ON
WIDE SIDE
OF WC
T.O. S
E
A
T
15-19"
F.O. FINISH
18"
F.O. TUB
15" MIN SIDE WALL36" MIN
MIN
12"
TYPE A/B WATER CLOSET
PLACEMENT
REAR GRAB BAR
F.O. FINISH
18"
SIDE WALL
3 3-3
6"
F.O. FINISH
18"
SIDE WALL
3 3-3
6"
REAR GRAB BAR ALT (PERMITTED
WHERE LAV OVERLAPS GRAB BAR AREA)
24" MIN
MIN
12"
REAR WALLREAR WALL
MAX
12" 24" MIN
MAX
12" 42" MIN
SIDE GRAB BAR SIDE GRAB BAR ALT (ONLY WHERE 42"
GRAB BAR CANNOT BE ACCOMODATED)
3 3-3
6"
3 3-3
6"
SWING-UP GRAB BARS
18" CLR 18" CLR
12" MIN
15 3/4" 15 3/4"
NOTE: GRAB BARS SHOWN FOR REFERENCE
TYPE B WATER CLOSET ALTERNATES ONLY, INSTALL BLOCKING ONLY
SWING-UP GRAB BARS
18" CLR
15 3/4"
MIN
12"
3 3-3
6"
UPPER
CABINET
SWITCH / OUTLET
LOWER
CABINET
T.O. B
O
X
4 4" M
AX
SWITCH AND OUTLET HEIGHTS
SWITCH
OUTLET
T.O. B
O
X
4 8" M
AX
B.O. B
O
X
15" MIN
UNOBSTRUCTED OBSTRUCTED
DRINKING FOUNTAIN
UNOBSTRUCTED
15" MIN
17-19"
4" MAX
MIN
9"
T
O
S
P
O
U
T
O
U
TLE
T
3 6" M
AX
S
TA
N
DIN
G
U
S
E
A
D
ULT
3 8-4
3"
ACCESSIBLE BATH ACCESSORIES
BABY CHANGING STATION
T.O. W
O
R
K
S
U
R
F
A
C
E
28-3
4"
T.O. H
A
N
DLE
4 4" M
AX
DIS
P
E
N
S
E
R
O
P
E
NIN
G
4 8" M
AX
PAPER TOWEL
DISPENSER
SOAP DISPENSER
P
U
S
H
B
U
T
T
O
N
4 4" M
AX
DIS
P
E
N
S
E
R
O
P
E
NIN
G
4 8" M
AX
TOILET SEAT
COVER DISPENSER
B.O. R
E
FLE
C
TIV
E
S
U
R
F
A
C
E
4 0" M
AX
MIRROR
NOTE: GRAB BARS SHOWN FOR REFERENCE, INSTALL BLOCKING ACCESSIBLE WATER CLOSET AT ALL LOCATIONS WHERE GRAB BARS ARE NOT SHOWN IN PLAN FLUSH
LEVER ON
WIDE SIDE
OF WC
T.O. S
E
A
T
15-19"
F.O. FINISH
18"
F.O. TUB
15" MIN SIDE WALL
ACCESSIBLE WATER CLOSET
PLACEMENT
REAR WALL
MAX
12" 42" MIN
SIDE GRAB BAR
3 3-3
6"
36" MIN
MIN
12"
REAR GRAB BAR
F.O. FINISH
18"
SIDE WALL
3 3-3
6"
39-41"
3 9-41" 18" MIN
REAR WALL
PROTRUDING TOILET PAPER DISPENSER
24" MIN
18" MIN
42" MAX
1 1/2" MIN
DISPENSER AREA
REMOVABLE CABINETS
BATHROOM KITCHEN
30" MIN CLR
REAR WALL
RECESSED TOILET PAPER DISPENSER
24" MIN
18" MIN
42" MAX
MIN
1 1/2"
DISPENSER AREA
36" MAX
4 8" M
AX
LOCATE
REMOVABLE
CABINET AT END
OF COUNTER
4 A-851
SEE MIRROR
REQUIREMENTS 4
A-851
30" MIN CLR
3 6" T
Y
P
E
B
3 4" T
Y
P
E
A / A
C
C
ROOM SIGNAGE
ELEVATION
NOTE: SIGNS SHALL BE CONSTRUCTED OF DURABLE MATERIALS,
PERMANENTLY INSTALLED AND READILY VISIBLE
ROOM NAME
201
MIN
9"
B.O. TA
C
TILE
C
O
P
Y
4 8" MIN
T.O. T
A
C
TILE
C
O
P
Y
6 0"
ROOM SIGN
NOTE: LOCATE SIGN ON
RIGHT SIDE OF RIGHT
LEAF AT DOUBLE DOORS
LOCATE SIGN ON ADJACENT
WALL WHERE THERE IS
INSUFFICIENT WALL SPACE
FOR SIGN, 18" CLEAR SPACE
MUST BE OUTSIDE OF ARC OF
DOOR IN 45 DEGREE POSITION
.:::..:::..:
E
Q
E
Q
PLAN AT ADJACENT MOUNTING
45°
18" MIN
18" MIN
LIMITS OF PROTRUDING OBJECTS VERTICAL CLEARANCE
8 0"
27" M
AX
4" MAX
27" MIN
NOTE: HANDRAILS SHALL BE PERMITTED
TO PROTRUDE 4 1/2" MAX OFF OF WALL
NOTE: DOOR CLOSERS AND STOPS PROTRUDING OBJECTS SHALL BE PERMITTED TO BE AT 78" AFF 8 0" MIN
VERTICAL BAR
AUTOMATIC
DOOR OPENER
PUSH
TO
OPEN
T.O. O
P
E
R
A
BLE
P
A
R
T
42"
6"
ACCESS CONTROLS
CARD READER DOOR ACTUATOR
3 6"
15" MIN
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:3
9 A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
ACCESSIBILITY
DETAILS
A-850
EN, KS, JL
AS
06/29/20
1/2" = 1'-0"A-850
1 ASSESSIBILITY DETAILS
BLUE
WHITE
x;TOWED VEHICLES
MAY BE RECLAIMED AT
OR BY TELEPHONING
XXXXXXXXXXXXXXXXXXXXXXX
(XXX) XXX-XXXX
x;UNAUTHORIZED VEHICLES PARKED
IN DESIGNATED ACCESSIBLE
SPACES NOT DISPLAYING
DISTINGUISHING PLACARDS OR
SPECIAL LICENSE PLATES ISSUED
FOR PERSONS WITH DISABILITIES
WILL BE TOWED AWAY
AT THE OWNER'S EXPENSE
80" MIN
16 GA. GALV. STL. SIGN
PAINTED OSHA BLUE
INCL. FASTENERS
9 1/2" HIGH ISA SYMBOL
AND 2 1/4" HIGH "PARKING
ONLY" PAINTED WITH
WHITE REFLECTORIZED
PAINT
1/2" WIDE BORDER PAINTED
WITH WHITE
REFLECTORIZED PAINT
16 GA. GALV. STL. SIGN
PAINTED WHITE INCL.
FASTENERS. TEXT:
"MINIMUM FINE OF $250"
FONT: ARIAL, BLACK
SIZE: 1"
16 GA. GALV. STL. SIGN
PAINTED OSHA BLUE
INCL. FASTENERS. 2 1/4"
HIGH "VAN ACCESSIBLE"
REFLECTORIZED PAINT.
80" MIN
FINISHED
GRADE
NOTES:
1. SIGNS SHALL BE PAINTED WHITE ON BLUE
BACKGROUND.
2. SIGNS IDENTIFYING VAN PARKING SPACES
SHALL CONTAIN ADDITIONAL LANGUAGE
OR AN ADDITIONAL SIGN WITH THE
DESIGNATION "VAN ACCESSIBLE."
3. SIGNS SHALL BE 80" MINIMUM ABOVE THE
FINISH FLOOR OR GROUND SURFACE
MEASURED TO THE BOTTOM OF SIGN.
4. IDENTIFICATION SIGNS SHALL BE
REFLECTORIZED WITH A MINIMUM AREA OF
70 SQUARE INCHES.
5. ADDITIONAL LANGUAGE OR AN ADDITIONAL
SIGN BELOW THE INTERNATIONAL SYMBOL
OF ACCESSIBILITY SHALL STATE "MINIMUM
FINE $250."
6. SIGN SHALL BE VISIBLE FROM EACH
ACCESSIBLE PARKING SPACE. SIGNS
SHALL BE PERMANENTLY POSTED EITHER
IMMEDIATELY ADJACENT TO THE PARKING
SPACE OR WITHIN THE PROJECTED
PARKING SPACE.
ACCESSIBLE PARKING
IDENTIFICATION SIGN
NTS
INTERNATIONAL SYMBOL
OF ACCESSIBILITY
NTS
AUTHORIZED ACCESSIBLE
PARKING DETAIL
NTS
NOTES:
1. CONTRACTOR SHALL CONFIRM TOWING
AND TELEPHONE INFORMATION WITH
OWNER PRIOR TO ORDERING SIGN
2. SIGN SHALL CONFORM TO THE 2019
CALIFORNIA BUILDING CODE
REQUIREMENTS.
NOTES:
1. SEE PARKING SPACE DETAILS FOR SYMBOL
LOCATIONS.
2. INTERNATIONAL ACCESSIBILITY PAVEMENT
SYMBOL SHALL COMPLY WITH TITLE 24 OF
THE CALIFORNIA BUILDING CODE AND LOCAL
CODES.
3. FOR REFERENCE ONLY. REFER TO CAMUTCD
FOR CURRENT REQUIREMENTS.
WHITE
BLUE
1" RADIUS, TYPICAL
5' - 0" MIN
4' - 6" MIN
4' - 0" MIN
4' - 0" MIN
3' - 0"
MIN
1' - 0"
MIN
1' - 6"
5% MAX CROSS
SLOPE AT GATE
CLEARANCES
PULL CLEARANCE
PUSH CLEARANCE
SEE REF GATE SHEET
2 FOR ELEVATIONS
72" MIN
6' - 0" MIN
5' - 0" MIN
4' - 0" MIN
4' - 0"
MIN
2' - 0"
MIN
1' - 0"
PUSH CLEARANCE
PULL CLEARANCE
5% MAX CROSS
SLOPE AT GATE
CLEARANCES
SEE REF GATE SHEET
2 FOR ELEVATIONS
KNEE CLEARANCE
COUNTER WITH SINK
NOTE: KNEE CLEARANCE
PER ANSI 117.1-2009
REMOVABLE
CABINET
WHERE
NOTED
FINISH FACE OF WALL,
INCLUDING WHERE
REMOVABLE CABINET
IS CALLED OUT
WRAP PLUMBING WITH
INSULATION
KITCHEN SINK
CONTINUE FLOORING
UNDER SINK, INCLUDING
WHERE REMOVABLE
CABINET IS CALLED OUT
GARBAGE DISPOSAL
WHERE NOTED
6" MAX
8" MIN
17" MIN
FIXED PANEL
BACKSPLASH
27" MIN
T.O. SINK RIM
34" MAX
9" MIN
22" TYP
24" MAX
1/2" MAX
1/4" MAX
1 2
1/4" MAX
NOTE: ACCESSIBLE
THRESHOLD TO HAVE 1:2
MAX SLOPE AT ALL
TRANSITIONS, 1/4" MAX
HEIGHT AT VERTICAL
PORTION OF SILL AND 1/2"
MAX OVERALL HEIGHT
DOOR PER
SCHEDULE
1/4" MAX
1 2
1 1/2"
CLR
1 1/2"
WALL FINISH
WOOD
HANDRAIL,
P3.1 FINISH
WALL BASE
PER ROOM
SCHEDULE
FLOOR FINISH
PER ROOM
SCHEDULE
36"
CLR
1 1/2"
1 1/2"
CLR
1 1/2"
METAL GRAB
BAR,
BRUSHED
NICKEL OR
APPROVED
EQUAL
SEE A-850
WALL FINISH
WALL BASE
PER ROOM
SCHEDULE
FLOOR FINISH
PER ROOM
SCHEDULE
BLOCKING AS
REQUIRED
BLOCKING AS
REQUIRED
WOMEN
6" HIGH INTERNATIONAL
ACCESSIBILITY SYMBOL
1" HIGH CONTRASTING
CHARACTERS PER SCHEDULE
6" HIGH "MEN" / "WOMEN" SYMBOL
GRADE 2 CLEAR BEAD
BRAILLE MATCHING
ROOM TEXT
1/8" THK. PLASTIC SIGN W/
CONTRASTING BACKGROUND.
MOUNT ON WALL 4" FROM LATCH
SIDE OF DOOR FRAME
T.O. SIGN
60" AFF
10"
10" 4"
COMMUNITY
GRADE 2 CLEAR BEAD BRAILLE
MATCHING ROOM TEXT
TACTILE SIGNAGE IDENTIFYING PERMANENT ROOMS
AND SPACES IS REQUIRED TO BE POSITIONED AT A
MAXIMUM OF 60" TO THE BASELINE OF THE HIGHEST LINE
OF RAISED ALPHA CHARACTERS AND MINIMUM 48" TO
THE BASELINE OF THE BRAILLE CELLS
1" HIGH CONTRASTING
CHARACTERS PER
SCHEDULE
T.O. SIGN
60" AFF
4"
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:30:39 AM
C:\Users\enavarro\Documents\_RevitLocal\2321 24_0903 Shelter Expansion_R21_enavarroQT4G7.rvt 2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
ACCESSIBILITY
DETAILS
A-851
EN, KS, JL
AS
10/03/24
1/4" = 1'-0"A-851 1 ACCESSIBLE EV PARKING SIGNS
1/4" = 1'-0"A-851 2 3'-0" GATE CLEARANCES1/4" = 1'-0"A-851 3 4'-0" GATE CLEARANCES 1" = 1'-0"A-851 4 ACCESSIBLE KNEE CLEARANCE
6" = 1'-0"A-851 5 ACCESSIBLE DOOR THRESHOLD
3" = 1'-0"A-851 6 HANDRAIL / GRAB BAR REQUIREMENTS
3" = 1'-0"A-851 8 PICTOGRAM ROOM SIGN - TYPE S2
3" = 1'-0"A-851 7 ROOM IDENTIFICATION SIGN - TYPE S1
FIRE RATED CAULKING
PER UL SYSTEM
AND/OR ACOUSTICAL
RATED CAULKING
ELECTRICAL BOX
HORIZONTAL SEPARATION
24" MIN
NOTE: RECEPTACLE
BOXES IN FIRE RATED
WALLS SHALL BE
STEEL OR APPROVED
FIRE RATED EQUAL.
THE ANNULAR SPACE
BETWEEN THE
MEMBRANE AND THE
BOX SHALL NOT
EXCEED 1/8" PER CBC
714.5.2.
FIRE RATED CAULKING
PER UL SYSTEM
AND/OR ACOUSTICAL
RATED CAULKING
ELECTRICAL BOX
HORIZONTAL SEPARATION
24" MIN
NOTE: RECEPTACLE
BOXES IN FIRE RATED
WALLS SHALL BE
STEEL OR APPROVED
FIRE RATED EQUAL.
THE ANNULAR SPACE
BETWEEN THE
MEMBRANE AND THE
BOX SHALL NOT
EXCEED 1/8" PER CBC
714.5.2.
IF HORIZONTAL
SEPARATION IS LESS
THAN 36", BOXES SHALL
BE BACKED WITH
FIRESTOPPING PUTTY
UL SYSTEM NO WL 1001 AT
METALLIC PIPE OR CONDUIT
CONDITIONS
UL SYSTEM NO WL 2003 AT NON-
METALLIC PIPE OR CONDUIT
CONDITIONS
FIRE RATED CAULKING PER UL
SYSTEM AND/OR ACOUSTICAL
RATED CAULKING
PIPE / DUCT
NOTE: ACOUSTICAL SEALANT
MUST BE PROVIDED AT ALL
SOUND RATED WALLS IN
ACCORDANCE WITH ASTM
STANDARD C919
NON-RATED INTERIOR WALL
RATED INTERIOR WALL TO
REMAIN CONTINUOUS
SOLID STUD OR NAILER
AT WALL INTERSECTION
CONTINUOUS GYP BOARD
BEHIND STUD AT
INTERSECTING PARTITIONS
PIPE RISER
UL SYSTEM NO WL 1001 AT METALLIC
PIPE OR CONDUIT CONDITIONS
UL SYSTEM NO WL 2003 AT NON-
METALLIC PIPE OR CONDUIT
CONDITIONS
NOTE: ACOUSTICAL SEALANT MUST
BE PROVIDED AT ALL SOUND RATED
WALLS IN ACCORDANCE WITH ASTM
STANDARD C919
FIRE RATED CAULKING PER UL
SYSTEM AND/OR ACOUSTICAL
RATED CAULKING
NOTE: RIGID PLUMBING SYSTEMS
SHALL BE INSTALLED ON VIBRATION
ISOLATION SYSTEMS
ELECTRICAL BOXES IN THE SAME
WALL CAVITY AND THAT ARE WITHIN
24" OF PLUMBING LINES THAT SHALL
BE BACKED WITH FIRESTOPPING
PUTTY
FIRE RATED CAULKING
PER UL SYSTEM
AND/OR ACOUSTICAL
RATED CAULKING
T.O. FLOOR ASSEMBLY
FIRE RATED CAULKING B.O. CEILNG ASSEMBLY
PER UL SYSTEM
AND/OR ACOUSTICAL
RATED CAULKING
NAILER AS REQUIRED
RECESSED / SEMI
RECESSED FIRE
EXTINGUISHER CABINET
INSTALLED PER
MANUFACTURER'S
INSTRUCTIONS
WRAP FRAMED OPENING W/
GYP BOARD TO MAINTAIN
ASSEMBLY RATING
INSULATION AS REQUIRED
PER ASSEMBLY
VRFY W/ MFR
CROSS RUNNER MAIN RUNNER
#12 SPLAYED
BRACE WIRES
NOTES:
1. SEISMIC BRACING SHALL COMPLY WITH CBC 1613 AND ASCE 7
2. AREA OF CEILING SUPPORTED NOT TO EXCEED 144 SF.
3. MAXIMUM BRACE SPACING NOT TO EXCEED 12' OC EACH WAY, 6' MAX FROM WALL
4. BRACE POINT ON MAIN RUNNER NOT TO EXCEED 2" DISTANCE FROM CROSS RUNNER. 45° OR LESS 45° OR LESS #12 HANGER WIRE
45° OR LESS
45° OR LESS
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:30:40 AM
C:\Users\enavarro\Documents\_RevitLocal\2321 24_0903 Shelter Expansion_R21_enavarroQT4G7.rvt 2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
INTERIOR
DETAILS - RATED
A-853
EN, KS, JL
AS
07/02/20
3" = 1'-0"A-853 1 BOX PENETRATION AT RATED WALL
3" = 1'-0"A-853 2 BOX PENETRATION AT PARTY WALL
3" = 1'-0"A-853 3 THRU PENETRATION AT RATED WALL3" = 1'-0"A-853 7 RATED TO NON-RATED WALL 3" = 1'-0"A-853 5 PLUMBING PENETRATION AT RATED WALL
3" = 1'-0"A-853 6 RATED WALL HEAD AND SILL
3" = 1'-0"A-853 9 RECESSED FEC AT RATED WALL
3" = 1'-0"A-853 4 DROPPED CEILING SEISMIC BRACING
WOOD TRIM
WINDOW SHIM
AS REQUIRED
WINDOW PER
SCHEDULE
WRAP GYPSUM
BOARD INTO
OPENING AT JAMB
AND HEAD
2x FRAMING
F.O. WALL
1/4"
CHAMFER AT
EXPOSED
EDGES
TOP OF SLAB
SEAL ALONG
WALL EDGES
3/4" MIN
1x6 COMPOSITE
WOOD WITH
COGNAC FINISH
20°
1/4" CHAMFER AT
FREE END
EDGES BEYOND
NOTE: WRAP COMPOSITE
WOOD AROUND FACE BEYOND
NTS
1' - 10 1/2"
1' - 6"
D
5 4"
15"
6" 30" 7" 40" 7" 30" 6"
15" 5
4"
18" 18"
SPRING HINGED
180 DEGREE
SALOON DOORS
PONY WALL BELOW
A-855
10 14 A-855
13 A-855
COUNTERTOP SUPPORT BELOW
1x PAINT GRADE WOOD WALL CAP
FLUSH WITH FACE OF WALL;
FINISHED TO MATCH WALL BELOW
LEVEL 1
0' - 0"
ARCHITECTURAL GRADE
PLYWOOD; SANDED
SMOOTH WITH SEALER
PLYWOOD EDGE FROM
BUTT JOINT AT FRONT SIDE
WALL BASE PER ROOM
SCHEDULE
LOWER QUARTZ
COUNTERTOP
UPPER QUARTZ
COUNTERTOP
SEALED TO
COUNTERTOP
BELOW
1x PAINT GRADE
WOOD WALL CAP
FLUSH WITH FACE
OF WALL; FINISHED
TO MATCH WALL
BELOW
SPRING HINGED 180
DEGREE SALOON DOORS
ARCHITECTURAL GRADE
PLYWOOD; SANDED
SMOOTH WITH SEALER
4"
LEVEL 1
0' - 0"
D
13 A-855
1/4" REVEAL
ARCHITECTURAL GRADE
PLYWOOD; SANDED
SMOOTH WITH SEALER
DRYWALL J-TRIM
REINFORCEMENT
AT REVEAL
WALL BASE PER
ROOM SCHEDULE
SUSPENSION WIRE -
SEE STRUCTURAL
PRE-MANUFACTURED
WOOD SLAT CEILING
RECESSED CAN LIGHT
BEYOND - SEE
ELECTRICAL
LOWER QUARTZ
COUNTERTOP
UPPER QUARTZ
COUNTERTOP SEALED TO
COUNTERTOP BELOW
DOUBLE 2x PONY WALL
WALL BASE PER ROOM SCHEDULE
1/4" R
E
V
E
AL
3 4" A
F
F
PLYWOOD WALL CAP
FLUSH WITH FACE OF
WALL; FINISHED TO
MATCH DOORS
PROJECT NUMBER:
CLIENT:
PHASE:
SHEET TITLE:
SHEET:
All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer.
REVISIONS:
1201 J STREET
SUITE 200
SACRAMENTO, CA 95814
PHONE: 916.269.8818
WWW.SALAZARCH.COM
DRAWN BY:
CHECKED BY:
DATE CREATED:
Salazar Architect, Inc.
# DATE DESCRIPTION
10/15/2024 10:3
0:41 A
M
C:\Users\enavarro\D
ocuments\_
RevitLocal\2321 24
_
0 9
0 3
Shelter E
x
p
ansion_
R21_enavarro
Q
T
4 G7.rvt
2321
SHELTER II AT
EAST BEAMER
1901 EAST BEAMER STREET
WOODLAND, CA 95776
APN:027-360-042
FRIENDS OF THE
MISSION
PO BOX 8485
WOODLAND, CA 95776
(916) 416-0901
BUILDING PERMIT
SUBMITTAL
INTERIOR
DETAILS
A-855
EN, KS, JL
AS
09/16/24
6" = 1'-0"A-855
1 INTERIOR WINDOW SILL -TYP
3" = 1'-0"A-855
2 BUILT IN BENCH
3/4" = 1'-0"A-855
9 FRONT DESK PLAN
3/4" = 1'-0"A-855
10 FRONT DESK DOOR ELEVATION
3/4" = 1'-0"A-855
14 FRONT DESK SIDE ELEVATION
1 1/2" = 1'-0"A-855
13 FRONT DESK SECTION
1. THIS DOCUMENT IS AN INSTRUMENT OF PROFESSIONAL SERVICE PREPARED BY STONECAP, INC. ALTERATION OF THIS DOCUMENT BY ANY PARTY OTHER THAN STONECAP, INC. IS A VIOLATION OF LAW THAT WILL BE PROSECUTED TO ITS FULLEST EXTENT.
2. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS & CONDITIONS AT THE JOB SITE PRIOR TO STARTING CONSTRUCTION AND THE ARCHITECT/ENGINEER SHALL BE NOTIFIED OF ANY DISCREPANCIES OR INCONSISTENCIES.
3. AT ANY DISCREPANCIES OR CONFLICTS BETWEEN PLAN AND ELEVATION DIMENSIONS SHOWN ON THE ARCHITECTURAL DRAWINGS AND THE STRUCTURAL DRAWINGS, THE ARCHITECTURAL DIMENSIONS SHALL GOVERN. IF ANY OF THESE DIMENSIONS DIFFER BY MORE THAN 5%, THE ENGINEER SHALL BE NOTIFIED OF THE CONFLICT, AND THE CONTRACTOR SHALL WAIT FOR INSTRUCTIONS.
4. ALL PHASES OF WORK SHALL CONFORM TO THE MINIMUM STANDARDS OF THE LATEST LOCALLY ADOPTED CODE AND ALL RELEASED ADDENDUMS.
5. THE CONTRACT CONSTRUCTION DRAWINGS AND SPECIFICATIONS REPRESENT THE FINISHED STRUCTURE. UNLESS OTHERWISE NOTED, THEY DO NOT INDICATE THE METHOD OF CONSTRUCTION. THE CONTRACTOR SHALL PROVIDE ALL MEASURES NECESSARY TO PROTECT THE STRUCTURE, WORKMEN, AND OTHER PERSONS DURING CONSTRUCTION. SUCH MEASURES SHALL INCLUDE, BUT NOT LIMITED TO: BRACING, ALL SHORING, FORMS, AND SCAFFOLDING.
6. OPENINGS, POCKETS, ETC. SHALL NOT BE PLACED IN SLABS BEAMS, COLUMNS, WALLS, ETC., UNLESS SPECIFICALLY DETAILED ON THE STRUCTURAL DRAWINGS.
7. ALL ASTM SPECIFICATIONS NOTED ON THESE DRAWINGS SHALL BE OF THE LATEST REVISION.
8. IN THE EVENT THAT CERTAIN FEATURES OF CONSTRUCTION ARE NOT FULLY SHOWN ON THE DRAWINGS OR CALLED FOR IN THE NOTES OR SPECIFICATIONS. NOTIFY THE ARCHITECT/ENGINEER IMMEDIATELY & WAIT FOR INSTRUCTIONS.
9. COST OF ADDITIONAL DESIGN WORK NECESSITATED BY SELECTION OF AN OPTION OR DUE TO ERRORS OR OMISSIONS IN CONSTRUCTION, SHALL BE BORN BY THE CONTRACTOR.
10. WHERE DESIGN AND DETAILS OF PLATE GIRDERS, TRUSSES, ETC., IS TO BE PROVIDED BY FABRICATOR CONTRACTOR SHALL
SUBMIT CALCULATIONS PREPARED BY A CIVIL OR STRUCTURAL ENGINEER, TO THE ENGINEER AND TO THE BUILDING DEPARTMENT FOR REVIEW PRIOR TO FABRICATION.
11. UNLESS AN ITEM ON THE PLANS OR DETAILS IS SPECIFICALLY MARKED AS AN EXISTING ITEM, THE CONTRACTOR IS TO ASSUME THAT IT IS NEW, AND INCLUDE IT IN THE CONSTRUCTION BUDGET.
12. WHERE SOIL REPORT IS CITED, ITS REQUIREMENTS ADOPTED HEREIN.
13. ALL MANUFACTURED PRODUCTS MUST BE INSTALLED PER MANUFACTURER'S RECOMMENDATION.
14. WHILE EVERY REASONABLE EFFORT HAS BEEN MADE TO PROVIDE A BUILDABLE SET ON CONTRACT DOCUMENTS WITH
MINIMAL ERRORS OR OMISSIONS, THE CONTRACTOR ACKNOWLEDGES AND UNDERSTANDS THAT THE CONTRACT DOCUMENTS
MAY REPRESENT IMPERFECT DATA AND MAY CONTAIN ERRORS, OMISSIONS, CONFLICTS, INCONSISTENCIES, CODE VIOLATIONS AND IMPROPER USE OF MATERIALS. SUCH DEFICIENCIES WILL BE CORRECTED BY THE ARCHITECT OR HIS CONSULTANTS WHEN IDENTIFIED. THE CONTRACTOR AGREES TO CAREFULLY STUDY AND COMPARE THE INDIVIDUAL CONTRACT DOCUMENTS AND REPORT AT ONCE IN WRITING TO THE ARCHITECT ANY DEFICIENCIES THE CONTRACTOR MAY DISCOVER. THE
CONTRACTOR FURTHER AGREES TO REQUIRE EACH SUBCONTRACTOR TO LIKEWISE STUDY THE DOCUMENTS AND TO REPORT AT ONCE ANY DEFICIENCIES DISCOVERED. THE CONSULTANT AND ARCHITECT, TOGETHER WITH CONTRACTOR SHALL RESOLVE ALL REPORTED DEFICIENCIES PRIOR TO STARTING ANY WORK. ANY QUESTIONABLE WORK PERFORMED PRIOR TO
RESOLUTION OF CONFLICTS OR ERRORS OR FURTHER CLARIFICATION FROM THE ARCHITECT WILL BE DONE AT THE CONTRACTOR'S RISK.
15. OPTIONS, IF PROVIDED HEREIN, ARE FOR CONTRACTOR'S CONVENIENCE. HE SHALL BE RESPONSIBLE FOR ALL CHANGES NECESSARY, SHALL COORDINATE ALL DETAILS, AND SHALL OBTAIN ALL REQUIRED APPROVALS.
16. ANY MECHANICAL AND ELECTRICAL EQUIPMENT, STORAGE RACKS, SAFES, AND ANY OBJECT EXPECTED TO BE IN THE BUILDING THAT HAS AN OPERATIONAL WEIGHT (FULLY LOADED) GREATER THEN 400 LB. FLOOR OR ROOF MOUNTED, OR GREATER THEN 200 LB. SUSPENDED FROM A FLOOR, CEILING OR WALL SHALL BE SHOWN ON THESE DRAWINGS. IF THEY ARE
NOT SHOWN ON THESE DRAWINGS, THEY SHALL BE BROUGHT TO THE ATTENTION OF THE STRUCTURAL ENGINEER, AND A CUT SHEET FOR THE SPECIFIC ITEM SHALL BE MADE AVAILABLE.
17. THE DEFERRED SUBMITTAL ITEMS SHALL BE SUBMITTED TO THE ARCHITECT OR ENGINEER OF RECORD WHO SHALL REVIEW
AND APPROVE THEM, AND FORWARD THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING THAT THE DEFERRED
SUBMITTAL DOCUMENTS HAVE BEEN REVIEWED AND APPROVED AND THAT THEY HAVE BEEN FOUND TO BE IN GENERAL CONFORMANCE WITH THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS SHALL NOT BE INSTALLED UNTIL THEIR DESIGN AND SUBMITTAL DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. PROVIDE AMPLE TIME FOR THE BUILDING OFFICIAL TO REVIEW THE DOCUMENTS.
18. CONSTRUCTION WASTE REDUCTION, DISPOSAL AND RECYCLING SHALL BE IN CONFORMANCE WITH THE REQUIREMENTS OF THE LATEST ADOPTED CALIFORNIA GREEN BUILDING CODE.
19. CONTRACTOR IS TO VERIFY THAT NO EXISTING STEEL REINFORCING, OR TENSION CABLES ARE DAMAGED WHEN INSTALLING POST INSTALLED WEDGE OR CHEMICAL ANCHORS. MECHANICAL ANCHORS ARE ONLY APPROVED FOR INTERIOR DRY USE, OTHERWISE CHEMICAL ANCHORS MUST BE USED.
GENERAL STRUCTURAL NOTES
1. SPECIAL INSPECTION U.N.O. BY A REGISTERED DEPUTY INSPECTOR APPROVED BY THE ARCHITECT AND/OR ENGINEER AND THE BUILDING DEPARTMENT SHALL BE EMPLOYED BY THE OWNER FOR THE FOLLOWING TYPES OF WORK:
A. FOUNDATION CONCRETE INVOLVING CONCRETE STRENGTH GREATER THAN 2500 P.S.I.
B. PERIODIC INSPECTION FOR SOILS IN SEISMIC DESIGN CATEGORIES D, E, AND F.
C. ALL WELDING. (EXCEPTIONS: WELDING DONE IN AN APPROVED FABRICATOR'S SHOP IN ACCORDANCE WITH AWS D1.1), ONLY PERIODIC INSPECTION IS REQUIRED FOR: SINGLE PASS FILLET WELDS LESS THEN 5/16", FLOOR AND ROOF DECK WELDS, WELDED STUDS ON A METAL DECK SYSTEM, WELDED COLD FOR STEEL, STAIRS, AND RAILING.
D. ALL POST INSTALLED CONCRETE OR MASONRY ANCHORS SUCH AS CHEMICAL AND MECHANICAL ANCHORS E. PERIODIC INSPECTION FOR ALL PLYWOOD DIAPHRAGMS, VERTICAL OR HORIZONTAL, WITH NAIL SPACING LESS THAN 4"OC. OR DOUBLE SIDED SHEAR WALLS.
F. PERIODIC INSPECTION FOR PLATE TRUSSES, TRUSS BLOCKING, HANGERS, AND TEMPORARY BRACING.
G. SEE C.B.C. VOL.II, SECTION 1704 FOR ADDITIONAL REQUIREMENTS. DEPUTY INSPECTION MAY BE WAVED FOR WORK THAT IS MINOR IN NATURE AS INTERPRETED BY THE BUILDING OFFICIAL.
2. THE SPECIAL INSPECTOR SHALL BE A QUALIFIED PERSON WHO SHALL DEMONSTRATE COMPETENCE, TO THE SATISFACTION OF
THE BUILDING OFFICIAL, FOR INSPECTION OF THE PARTICULAR TYPE OF CONSTRUCTION OR OPERATION REQUIRING SPECIAL INSPECTION. THE SPECIAL INSPECTOR SHALL OBSERVE THE WORK ASSIGNED FOR CONFORMANCE TO THE APPROVED DESIGN DRAWINGS AND SPECIFICATIONS. THE SPECIAL INSPECTOR SHALL FURNISH INSPECTION REPORTS TO THE BUILDING OFFICIAL, THE ENGINEER OR ARCHITECT OF RECORD, AND OTHER DESIGNATED PERSONS. ALL DISCREPANCIES SHALL BE BROUGHT TO
THE IMMEDIATE ATTENTION OF THE CONTRACTOR FOR CORRECTION, THEN, IF UNCORRECTED, TO THE PROPER DESIGN AUTHORITY AND TO THE BUILDING OFFICIAL. THE SPECIAL INSPECTOR SHALL SUBMIT A FINAL SIGNED REPORT STATING
WHETHER THE WORK REQUIRING SPECIAL INSPECTION WAS, TO THE BEST OF THE INSPECTOR'S KNOWLEDGE, IN
CONFORMANCE TO THE APPROVED PLANS AND SPECIFICATIONS AND THE APPLICABLE WORKMANSHIP PROVISIONS OF THE CODE PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
3. EACH CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF A MAIN WIND-OR SEISMIC-FORCE-RESISTING SYSTEM,
DESIGNATED SEISMIC SYSTEM OR A WIND-OR SEISMIC-RESISTING COMPONENT LISTED IN THE STATEMENT OF SPECIAL
INSPECTION SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL CONTAIN THE FOLLOWING:
A. ACKNOWLEDGMENT OF AWARENESS OF THE SPECIAL REQUIREMENTS CONTAINED IN THE STATEMENT OF SPECIAL INSPECTIONS;
B. ACKNOWLEDGMENT THAT CONTROL WILL BE EXERCISED TO OBTAIN CONFORMANCE WITH CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL;
C. PROCEDURES FOR EXERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND THE DISTRIBUTION OF THE REPORTS; AND
D. IDENTIFICATION AND QUALIFICATION OF THE PERSON(S) EXERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE ORGANIZATION.
SPECIAL INSPECTIONS
1. SHOP AND ERECTION DRAWINGS SERVE TO AID SUBCONTRACTORS IN THE PERFORMANCE OF THEIR WORK. THE
CONTRACTOR SHALL REVIEW SUBMITTALS RECEIVED BY THEIR SUBCONTRACTORS FOR COMPLIANCE AND CONFORMANCE WITH THE REQUIREMENTS OF THE STRUCTURAL DRAWINGS AND MARK ANY DISCREPANCIES. SHOP AND ERECTION DRAWINGS
SHALL INCORPORATE THE LATEST REVISIONS TO THE STRUCTURAL DRAWINGS AND THOSE THAT DO NOT SHALL BE FORWARDED TO THE DESIGN TEAM FOR REVIEW. THE CONTRACTOR SHALL ASSIGN A NUMBER TO EACH SUBMITTAL AND PROVIDE A REVIEW STAMP AND SIGNATURE.
2. WHERE THE FOLLOWING TYPES OF WORK ARE SHOWN IN THE PLANS, SHOP AND ERECTION DRAWINGS ARE REQUIRED:
A. REINFORCING STEEL.
B. CONCRETE MIX DESIGNS.
C. STRUCTURAL STEEL.
D. STEEL STAIRS, HANDRAILS, GUARDRAILS, AND LANDINGS.
E. FIRE SPRINKLER SUPPORT.
F. ROOF AND FLOOR PREMANUFACTURED TRUSSES
3. INDIVIDUAL MEMBERS SHALL BE CROSS-REFERENCED TO GRIDLINES FOR PURPOSES OF LOCATION. WORK SHALL NOT BEGIN UNTIL THE SHOP AND ERECTION DRAWINGS REVIEWED BY THE STRUCTURAL ENGINEER ARE RECEIVED AT THE JOBSITE.
4. CORRECTIONS OR COMMENTS MADE BY THE STRUCTURAL ENGINEER ON THE SHOP AND ERECTION DRAWINGS DURING
REVIEW DO NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE REQUIREMENTS OF THE DRAWINGS AND SPECIFICATIONS. REVIEW IS ONLY FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT OF THE PROJECT AND GENERAL COMPLIANCE WITH THE INFORMATION GIVEN IN THE CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR
CONFIRMING AND CORRELATING ALL QUANTITIES AND DIMENSIONS, SELECTING FABRICATION PROCESSES AND TECHNIQUES
OF CONSTRUCTION, COORDINATING WORK WITH THAT OF ALL OTHER TRADES, AND PERFORMING HIS WORK IN A SAFE AND SATISFACTORY MANNER.
5. IN ORDER TO REDUCE THE POSSIBILITY OF ERRORS IN TRANSFERRING REDMARKS TO NUMEROUS COPIES OF RETURNED
SHOP AND ERECTION DRAWINGS, ONLY ONE REPRODUCIBLE AND ONE COPY SHALL BE SENT TO THE STRUCTURAL ENGINEER FOR REVIEW. ONE REVIEW STAMPED REPRODUCIBLE WILL BE RETURNED. ADDITIONAL PRINTS FOR DISTRIBUTION BY THE CONTRACTOR CAN BE RUN FROM THE REPRODUCIBLE.
SHOP AND ERECTION DRAWINGS
1. DESIGN OF HANGERS, SWAY BRACING, AND ATTACHMENT TO THE STRUCTURE IS A DEFERRED SUBMITTAL ITEM. SEE DESIGN/BUILD NOTES FOR REQUIREMENTS.
2. CONTRACTOR SHALL SUBMIT DRAWINGS TO THE STRUCTURAL ENGINEER PRIOR TO THE START OF FRAMING. PROVIDE PIPE SIZES, WET PIPE WEIGHTS, AND PROPOSED DETAILS FOR ATTACHMENT. SIZE OF MEMBERS MAY BE SUBJECT TO CHANGE DUE TO PIPE LOCATIONS. INSTALLATION OF FRAMING SHALL NOT PROCEED UNTIL SHOP DRAWINGS AND METHOD OF STRENGTHENING, IF REQUIRED, HAVE BEEN DETERMINED.
3. LOCATE MAIN LINE NEAR COLUMNS AND ATTACH TO STEEL BEAMS, MANUFACTURED LUMBER, WOOD I-JOISTS, WOOD TRUSSES, STEEL JOISTS, AND CONCRETE BEAMS ONLY.
4. CONNECT BRANCH LINES TO STEEL BEAMS, CONCRETE OVER METAL DECK, MANUFACTURED LUMBER, WOOD I-JOISTS, WOOD TRUSSES, STEEL JOISTS, AND CONCRETE BEAMS ONLY. DO NOT CONNECT TO METAL DECK THAT DOES NOT HAVE STRUCTURAL CONCRETE FILL. CONNECTIONS FOR BRANCH LINES IN AREAS OF 2X FRAMING SHALL BE MADE TO DOUBLE 2X'S OR TO 4X'S, CONTRACTOR TO COORDINATE.
5. CONNECTIONS TO MANUFACTURED LUMBER SHALL OCCUR WITHIN THE MIDDLE THIRD OF THE MEMBER DEPTH.
6. THE METAL DECK, WOOD I-JOISTS, WOOD TRUSSES, AND STEEL JOIST MANUFACTURERS SHALL VERIFY ADEQUACY OF THEIR PRODUCTS TO SUPPORT HANGER LOADS. CONTACT THE MANUFACTURER FOR ACCEPTABLE CONNECTION DETAILS.
FIRE SPRINKLER SUPPORT
1. THE ABBREVIATION "GC" WHERE SHOWN ON THE DRAWINGS INDICATES GENERAL CONTRACTOR, OR IN THE CASE WHERE THE
PROJECT DOES NOT HAVE A GENERAL CONTRACTOR, THE CONTRACTOR RESPONSIBLE FOR THE DESIGN/BUILD OR DEFERRED SUBMITTAL ITEM.
2. THE CONTRACTOR SHALL CONTACT THE BUILDING DEPARTMENT TO DETERMINE WHICH DESIGN/BUILD ITEMS ARE REQUIRE A PERMIT THROUGH THE DEFERRED APPROVAL PROCESS.
3. FOR THOSE ITEMS REQUIRING DEFERRED APPROVAL, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING PERMITS.
THE CONTRACTOR SHALL PREPARE ALL REQUIRED DOCUMENTS: CALCULATIONS, SHOP DRAWINGS, MATERIAL
SPECIFICATIONS AND DATA SHEETS, ALL OF WHICH SHALL BE STAMPED AND SIGNED BY A PROFESSIONAL ENGINEER LICENSED IN THE PROJECT STATE. IN THE EVENT THAT THE CONTRACTOR IS UNABLE TO OBTAIN OUTSIDE STRUCTURAL ENGINEERING SERVICES, NCE CAN BE CONTRACTED TO PERFORM SUCH SERVICES AT AN ADDITIONAL FEE. PRIOR TO THE
CONTRACTOR'S SUBMITTAL TO THE BUILDING DEPARTMENT, ALL DOCUMENTS SHALL BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR REVIEW. THIS REVIEW IS LIMITED TO VERIFICATION THAT THE DESIGN COMPLIES WITH THE PROJECT DESIGN
LOADING CRITERIA, THAT THE PRIMARY STRUCTURAL SYSTEM IS CAPABLE OF SUPPORTING THE IMPOSED LOADS AT CONNECTION POINTS, AND FOR COORDINATION AS REQUIRED. THE PREPARER OF THE DOCUMENTS IS SOLELY RESPONSIBLE FOR THEIR DESIGN. THE STRUCTURAL ENGINEER IS NOT RESPONSIBLE FOR VERIFICATION OF CODE COMPLIANCE. THE
CONTRACTOR SHALL SUBMIT DOCUMENTS TO THE BUILDING DEPARTMENT AND RESOLVE ALL PLAN CHECK CORRECTIONS TO OBTAIN A PERMIT. FABRICATION AND INSTALLATION OF DESIGN/BUILD AND DEFERRED APPROVAL ITEMS SHALL NOT PROCEED
UNTIL THE DESIGN TEAM HAS REVIEWED THE DOCUMENTS AND THE CONTRACTOR HAS OBTAINED A PERMIT FOR THE ITEMS REQUIRING DEFERRED APPROVAL.
4. THE CONTRACTOR SHALL COORDINATE WITH OTHER TRADES, THE ARCHITECT, AND OTHER CONSULTANTS. DESIGN SHALL INCLUDE THE DESIGN OF THE ELEMENT AND ITS CONNECTION TO THE STRUCTURE. THE STRUCTURAL ENGINEER HAS NOT DESIGNED THE FOLLOWING ITEMS:
A. FIRE SPRINKLER SUPPORT.
B. ROOF AND FLOOR PREMANUFACTURED TRUSSES, AND COMMERCIAL JOISTS C. PREMANUFACTURED BALCONIES INCLUDING JULIET BALCONIES
5. ANY STRUCTURE THAT IS NOT SHOWN ON THE STRUCTURAL DRAWINGS BUT IS REQUIRED BY OTHER DISCIPLINES, SUCH AS ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING, LANDSCAPE, ETC.
6. ALL PIPES, DUCTS, AND CONDUIT SHALL BE BRACED TO RESIST THE FORCES PRESCRIBED IN ASCE 7 SECTION 13.6 WITH DETAILS IN ACCORDANCE WITH THE SMACNA SEISMIC RESTRAINT MANUAL, GUIDELINES FOR MECHANICAL SYSTEMS.
DESIGN/BUILD AND DEFERRED SUBMITTAL REQUIREMENTS:
1. FOUNDATION DESIGN IS BASED ON THE SOIL INVESTIGATION REPORT BY:
WALLACE KUHL & ASSOCIATES
WKA NO. 12185.02P DATED JANUARY 29, 2020
3050 INDUSTRIAL BOULEVARD
WEST SACRAMENTO, CA95691
CONTACT INFORMATION 916.372.1434
2. DESIGN SOIL BEARING PRESSURE IS 2000 PSF @ 12" MIN. BELOW LOWEST ADJACENT GRADE.
3. PRIOR TO THE CONTRACTOR REQUESTING A BUILDING DEPT. FOUNDATION INSPECTION, THE SOILS ENGINEER SHALL ADVISE THE BUILDING OFFICIAL, IN WRITING, THAT:
A. THE BUILDING PAD WAS PREPARED ACCORDING TO THE SOILS REPORT.
B. THE FOUNDATION EXCAVATIONS COMPLY WITH THE INTENT OF THE SOILS REPORT.
C. THE UTILITY TRENCHES HAVE BEEN PROPERLY BACK FILLED AND COMPACTED.
4. THE SOILS REPORT IS AN INTEGRAL PART OF THE CONSTRUCTION DOCUMENTS. ANY INCONSISTENCIES OR CONFLICTS SHOULD BE BROUGHT TO OUR ATTENTION IMMEDIATELY, AND WAIT FOR OUR DIRECTION.
5. REFERENCE THE SOILS REPORT FOR OVER EXCAVATION, LAYMENT OF BIAXLE GRID/GEOFABRIC, AND RECOMPACTION, AND OPTIMUM MOISTURE LEVEL INSTRUCTIONS.
6. IT IS THE CONTRACTORS RESPONSIBILITY TO VERIFY FINAL GRADE ELEVATIONS, FOR MINIMUM FOOTING DEPTHS BELOW LOWEST ADJACENT GRADES AND MINIMUM COVERAGE OVER TOP OF FOOTINGS. ELEVATIONS OF FOOTINGS SHOWN ON THESE PLANS ARE ESTIMATES BASED ON THE INFORMATION AVAILABLE. FOOTING ELEVATIONS ARE SUBJECT TO CHANGE,
AND ARE NOT FINAL TILL THE BUILDING PAD IS GRADED AND TRENCHES FOR FOOTINGS HAVE BEEN APPROVED BY THE SOILS ENGINEER OF RECORD.
7. THE CONTRACTOR IS TO VERIFY IF THE SOILS ENGINEER REQUIRES ADDITIONAL TESTING AT THE COMPLETION OF GRADING OF THE BUILDING PAD.
8. PRIOR TO BEING DELIVERED TO THE SITE, ALL IMPORTED SOIL SHALL BE TESTED AND APPROVED BY THE SOILS ENGINEER FOR CORROSIVITY AND SUITABILITY FOR THE FOUNDATION DESIGN.
9. BACKFILL BEHIND ALL RETAINING WALLS SHALL BE FREE DRAINING PER RECOMMENDATIONS OF THE SOILS REPORT.
10. EXCAVATION FOR ANY PURPOSE SHALL NOT REMOVE LATERAL SUPPORT FROM ANY FOUNDATION WITHOUT FIRST UNDERPINNING OR PROTECTING THE FOUNDATION AGAINST SETTLEMENT OR LATERAL TRANSLATION.
11. THE EXCAVATION OUTSIDE THE FOUNDATION SHALL BE BACKFILLED WITH SOIL THAT IS FREE OF ORGANIC MATERIAL, CONSTRUCTION DEBRIS, COBBLES AND BOULDERS OR WITH A CONTROLLED LOW-STRENGTH MATERIAL (CLSM). THE BACKFILL
SHALL BE PLACED IN LIFTS AND COMPACTED IN A MANOR THAT DOES NOT DAMAGE THE FOUNDATION OR THE WATERPROOFING OR DAMPPROOFING MATERIAL. EXCEPTION: CLSM NEED NOT BE COMPACTED.
12. THE GROUND IMMEDIATELY ADJACENT TO THE FOUNDATION SHALL BE SLOPED AWAY FROM THE BUILDING AT A SLOPE OF NOT LESS THAN ONE UNIT VERTICAL IN 20 UNITS HORIZONTAL (5-PERCENT SLOPE) FOR A MINIMUM DISTANCE OF 10 FEET (3048 MM) MEASURED PERPENDICULAR TO THE FACE OF THE WALL. IF PHYSICAL OBSTRUCTIONS OR LOT LINES PROHIBIT 10 FEET (3048 MM) OF HORIZONTAL DISTANCE, A 5-PERCENT SLOPE SHALL BE PROVIDED TO AN APPROVED ALTERNATIVE METHOD OF DIVERTING WATER AWAY FROM FOUNDATION. SWALES USED FOR THIS PURPOSE SHALL BE SLOPED A MINIMUM OF 2 PERCENT WHERE LOCATED WITHIN 10 FEET (3048 MM) OF THE BUILDING FOUNDATION. IMPERVIOUS SURFACES WITHIN 10 FEET (3048 MM) OF THE BUILDING FOUNDATION SHALL BE SLOPED A MINIMUM OF 2 PERCENT AWAY FROM THE BUILDING. EXCEPTION: WHERE
CLIMATIC OR SOIL CONDITIONS WARRANT, THE SLOPE OF THE GROUND AWAY FROM THE BUILDING FOUNDATION SHALL BE PERMITTED TO BE REDUCED TO NOT LESS THAN ONE UNIT VERTICAL IN 48 UNITS HORIZONTAL (2-PERCENT SLOPE). THE
PROCEDURE USED TO ESTABLISH THE FINAL GROUND LEVEL ADJACENT TO THE FOUNDATION SHALL ACCOUNT FOR ADDITIONAL SETTLEMENT OF THE BACKFILL.
FOUNDATION NOTES
1. FLOOR LIVE LOADS = 50 PSF [1603.1.1 CBC]
FLOOR DEAD LOADS = 25 PSF
EGRESS LIVE LOADS = 100 PSF
BALCONY LIVE LOADS = 60 PSF
STAIR AND EXIT LIVE LOADS = NA
2. GROUND SNOW LOAD, Pg = NA
FLAT-ROOF LOAD, Pf = NA (ONLY WHERE Pg EXCEEDS 10 PSF)
EXPOSURE FACTOR, I = NA (ONLY WHERE Pg EXCEEDS 10 PSF)
THERMAL FACTOR, Ct = NA (ONLY WHERE Pg EXCEEDS 10 PSF)
3. ROOF LIVE LOAD = 20 PSF [1603.1.2 CBC]
4. [1603.1.4 CBC] WIND DESIGN DATA:
ASD WIND SPEED (3-SEC GUST) = 85 MPH
ULTIMATE WIND SPEED (3-SEC GUST) = 110 MPH
WIND RISK CATEGORY = II
WIND EXPOSURE(S) = B
5. [1603.1.5 CBC] EARTHQUAKE DESIGN DATA:
SEISMIC RISK CATEGORY = II
MAPPED SPECTRAL RESPONSE ACCELERATIONS, Ss = 0.870g & SI = 0.322g SITE CLASS = D
SPECTRAL RESPONSE COEFFICIENTS, SDS = 0.668g
SEISMIC DESIGN CATEGORY = D
BASIC SEISMIC-FORCE RESISTING SYSTEM(S)= A.15 (LIGHT FRAMED WOOD WALLS SHEATHED W/ WOOD STRUCTURAL
PANELS RATED FOR SHEAR RESISTANCE)
BASIC SEISMIC-FORCE RESISTING SYSTEM(@ COMMERCIAL SPACE) = C.1 (STEEL SPECIAL MOMENT FRAME) DESIGN BASE SHEAR V = 0.1028W
SEISMIC RESPONSE COEFFICIENT(S), CS = 0.1028
RESPONSE MODIFICATIONS FACTOR(S), R = 6.5
ANALYSIS PROCEDURE USED: EQUIVALENT LATERAL FORCE PROCEDURE
DESIGN CRITERIA
1. CONCRETE MIXES SHALL BE DESIGNED BY A RECOGNIZED TESTING LABORATORY AND COPIES OF THE DESIGN SHALL BE SENT TO THE ARCHITECT AND THE ENGINEER. COMPRESSIVE STRENGTH TEST REPORTS SHALL BE SUBMITTED TO THE BUILDING DEPARTMENT AND THE ARCHITECT. ALL CONCRETE EXCEPT FOUNDATION CONCRETE SHALL CONTAIN POLYMER BASED WATER REDUCING ADMIXTURE.
2. PORTLAND CEMENT SHALL CONFORM TO ASTM C-150. TYPE II. AGGREGATE FOR STONE CONCRETE SHALL CONFORM TO ASTM C-33. NON-REACTIVE AGGREGATE FOR LIGHTWEIGHT CONCRETE SHALL CONFORM ASTM C-330.
3. ALL REINFORCING BARS, ANCHOR BOLTS, PRE STRESSING TENDONS, AND ALL OTHER CONCRETE INSERTS SHALL BE WELL SECURED IN POSITION PRIOR TO PLACING CONCRETE.
4. THE MAXIMUM SLUMP SHALL NOT EXCEED 4" +/- 1" FOR FOOTINGS, SLABS ON EARTH, AND MASS CONCRETE, AND 5" +/- 1" FOR OTHER CONCRETE. SLUMP MAY BE INCREASED WHEN CHEMICAL ADMIXTURES ARE USED, PROVIDED THAT ADMIXTURETREATED CONCRETE HAS THE SAME OR LOWER WATER: CEMENT OR WATER: CEMENTITIOUS MATERIAL RATIO. (ACI 211 TABLE
6.3.1)
5. MINIMUM COMPRESSIVE STRENGTH:
A. PROVIDE CONCRETE WITH THE FOLLOWING MINIMUM COMPRESSIVE STRENGTH (f'c) AT 28 DAYS UNLESS NOTED OTHERWISE (MINIMUM 5 SACKS OF CEMENT PER CUBIC YARD) (MAXIMUM WATER/CEMENT RATIO BY WEIGHT SHALL BE .65 FOR BALANCE):
a. SLABS ON GRADE............................................................................ 3000 P.S.I.*(HARDROCK) b. SPREAD FOOTING.............................................................................3000 P.S.I. (HARDROCK) c. CONTINUOUS FOOTINGS.................................................................... 3000 P.S.I. (HARDROCK) d. FOOTING UNDER CONC. SHEAR WALLS............................................ 4000 P.S.I. (HARDROCK) e. RETAINING WALLS............................................................................. 3000 P.S.I. (HARDROCK) f. STRUCTURAL SLABS......................................................................... 5000 P.S.I. (HARDROCK) g. COLUMNS.......................................................................................... 4000 P.S.I. (HARDROCK) h. BEAMS............................................................................................... 5000 P.S.I. (HARDROCK) i. SHEAR WALLS................................................................................... 4000 P.S.I. (HARDROCK) j. OTHER WALLS...................................................................................3000 P.S.I. (HARDROCK) k. CONCRETE OVER METAL DECK.......................................................... 4000 P.S.I. (LIGHTWEIGHT) B. * 2500 PSI STRENGTH USED FOR DESIGN, SPECIAL INSPECTION NOT REQUIRED.
6. THE COMPRESSIVE STRENGTH OF EXTERIOR SLABS AND FLAT WORK SHALL BE INCREASED FOR MODERATE AND SEVERE WEATHERING EXPOSURE PER TABLE 1904.2.2 OF THE CBC.
7. ALL STRUCTURAL CONCRETE IS TO BE REINFORCED.
8. CONTRACTOR SHALL SUBMIT SLAB CONSTRUCTION JOINT LAYOUT DRAWINGS TO THE ARCHITECT AND ENGINEER FOR REVIEW.
9. PROJECTING CORNERS OF BEAMS, COLUMNS, WALLS, ETC.. SHALL BE FORMED WITH A 3/4" CHAMFER UNLESS DETAILED OTHERWISE.
10. IF EXPOSURE TO SULFATES, OR SPECIAL EXPOSURE CONDITIONS OCCUR, THE CONCRETE STRENGTH, WATER CEMENT RATIOS, AND OTHER PROPERTIES OF THE CONCRETE MIX SHALL BE IN ACCORDANCE WITH ACI 318 SECTION 4.3. VERIFY WITH SOILS REPORT FOR CORROSIVE CHEMICALS IN THE SOILS.
11. THE MAXIMUM SPACING OF CONTROL JOINTS IN SLAB ON GRADE EACH WAY SHALL BE 30X THE SLAB THICKNESS BEFORE 7 DAYS OF CURING. SLABS REQUIRE AT LEAST 7 DAYS CURING (14 DAYS WHERE FLY ASH OR POZOLAN IS USED), AND THE
ENVIRONMENT (HUMIDITY AND TEMPERATURE) OF ROOM SHALL BE ACCLIMATED TO LONG TERM CLIMATE CONDITIONS PRIOR TO INSTALLATION OF FLOORING. THE SLAB TEMPERATURE SHALL BE WITHIN 5 DEGREES OF DEW POINT DURING CURING. NO CURING COMPOUND SHALL BE USED, ONLY WET CURED. MOISTURE AND HUMIDITY TESTING SHALL BE PERFORMED BY AN
INDEPENDENT TESTING LABORATORY HIRED BY THE OWNER, AND TESTS RESULTS SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL PRIOR TO INSTALLATION OF FLOORING.
12. DO NOT POUR CONCRETE WHEN THE TEMPERATURE EXCEEDS 90°F OR 80°F WHEN THE WIND EXCEEDS 12MPH.
13. START CURING AS SOON AS HARD TRAWLING IS DONE. ALL CURING SHALL BE WET CURING BY USING BURLAP FOR A MINIMUM OF 7 DAYS. BURLAP MUST BE PLACED WITHIN 2 HOURS OF POURING (NO SPRAY CURING).
14. WHEN WIND, TEMPERATURE AND HUMIDITY CONDITIONS CAUSE EARLY DISAPPEARANCE OF BLEED WATER, STEPS SHALL BE TAKEN TO USE A FOG SPRAY. CURING SHALL COMMENCE IMMEDIATELY AFTER FINISHING TRAWLING.
15. WHERE AIR ENTRAINED CONCRETE IS SPECIFIED, THE VOLUME OF AIR IN THE MORTAR FRACTION OF CONCRETE MIX DESIGN SHALL BE 9% ±1%.
16. ALL REINFORCING STEEL SHALL CONFORM TO THE REQUIREMENTS OF ASTM A-615 GRADE 60 FOR NO.5 AND LARGER, ASTM A-615 GRADE 40 FOR NO.4 AND SMALLER. AT GRADE BEAMS & CONCRETE FRAMES ALL REINF. SHALL CONFORM TO ASTM A706 REBAR.
17. WIRE MESH SHALL CONFORM TO ASTM A-185, AND SHALL BE LAPPED 1-1/2 SPACES OR 12" MINIMUM.
18. ALL REINFORCING BAR BENDS SHALL BE MADE COLD.
19. REINFORCING STEEL SHALL BE SPLICED WITH CLASS B SPLICES UNLESS NOTED OTHERWISE ON THE DRAWINGS.
20. LOW HYDROGEN ELECTRODES SHALL BE USED WHEREVER REINFORCING STEEL IS WELDED. BARS SHALL BE A706 GRD. 60 MIN. FOR WELD ABILITY.
21. AT THE TIME CONCRETE IS PLACED, REINFORCEMENT SHALL BE FREE FROM MUD, OIL, OR OTHER NONMETALLIC COATINGS THAT DECREASE BOND. WHERE SPECIFIED IN THE DETAILS, EPOXY-COATING OF STEEL REINFORCEMENT IN ACCORDANCE WITH ACI STANDARDS.
22. EXCEPT FOR PRESTRESSING STEEL, STEEL REINFORCEMENT WITH RUST, MILL SCALE, OR A COMBINATION OF BOTH SHALL BE
CONSIDERED SATISFACTORY, PROVIDED THE MINIMUM DIMENSIONS (INCLUDING HEIGHT OF DEFORMATIONS) AND WEIGHT OF A HAND-WIRE-BRUSHED TEST SPECIMEN COMPLY WITH APPLICABLE ASTM SPECIFICATIONS.
23. THE MINIMUM CLEAR SPACING BETWEEN PARALLEL BARS IN A LAYER SHALL BE db BUT NOT LESS THAN 1 IN.
24. WHERE PARALLEL REINFORCEMENT IS PLACED IN TWO OR MORE LAYERS, BARS IN THE UPPER LAYERS SHALL BE PLACED DIRECTLY ABOVE BARS IN THE BOTTOM LAYER WITH CLEAR DISTANCE BETWEEN LAYERS NOT LESS THAN 1 IN.
25. IN SPIRALLY REINFORCED OR TIED REINFORCED COMPRESSION MEMBERS, CLEAR DISTANCE BETWEEN LONGITUDINAL BARS SHALL BE NOT LESS THAN 1.5db NOR LESS THAN 11/2 IN.
26. CLEAR DISTANCE LIMITATION BETWEEN BARS SHALL APPLY ALSO TO THE CLEAR DISTANCE BETWEEN A CONTACT LAP SPLICE AND ADJACENT SPLICES OR BARS.
27. IN WALLS AND SLABS OTHER THAN CONCRETE JOIST CONSTRUCTION, PRIMARY FLEXURAL REINFORCEMENT SHALL NOT BE SPACED FARTHER APART THAN THREE TIMES THE WALL OR SLAB THICKNESS, NOR FARTHER APART THAN 18 IN.
28. GROUPS OF PARALLEL REINFORCING BARS BUNDLED IN CONTACT TO ACT AS A UNIT SHALL BE LIMITED TO FOUR IN ANY ONE BUNDLE.
29. BUNDLED BARS SHALL BE ENCLOSED WITHIN STIRRUPS OR TIES.
30. BARS LARGER THAN NO. 11 SHALL NOT BE BUNDLED IN BEAMS.
31. INDIVIDUAL BARS WITHIN A BUNDLE TERMINATED WITHIN THE SPAN OF FLEXURAL MEMBERS SHALL TERMINATE AT DIFFERENT POINTS WITH AT LEAST 40db STAGGER.
32. WHERE CONCRETE MUST BE INSTALLED AND CURED IN COLD WEATHER, THE GENERAL REQUIREMENTS AND SPECIFICATIONS OF ASTM STD C-31 SHALL BE IMPLEMENTED.
33. CAST-IN-PLACE CONCRETE (NON-PRESTRESSED)
A. THE FOLLOWING MINIMUM CONCRETE COVER SHALL BE PROVIDED FOR REINFORCEMENT:
a. CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH.........................................3" MIN. b. CONCRETE EXPOSED TO EARTH OR WEATHER:
• NO.6 THROUGH NO.18 BARS........................................................................................2" MIN. • NO.5 BAR, W31 OR D31 WIRE, AND SMALLER..........................................................1 1/2" MIN. c. CONCRETE NOT EXPOSED TO WEATHER OR IN CONTACT WITH GROUND:
d. SLABS, WALLS, JOISTS:
• NO.14 AND NO.18 BARS............................................................................................11/2" MIN. • NO.11 BAR AND SMALLER...........................................................................................3/4" MIN. e. BEAMS, COLUMNS:
• PRIMARY REINFORCEMENT, TIES, STIRRUPS, SPIRALS................................................11/2" MIN. f. SHELLS, FOLDED PLATE MEMBERS:
• NO.6 BAR AND LARGER...............................................................................................3/4" MIN. • NO.5 BAR, W31 OR D31 WIRE, AND SMALLER............................................................1/2" MIN.
34. BUNDLED BARS:
FOR BUNDLED BARS, MINIMUM CONCRETE COVER SHALL BE EQUAL TO THE EQUIVALENT DIAMETER OF THE BUNDLE, BUT NEED NOT TO BE GREATER THAN 2 IN.; EXCEPT FOR CONCRETE CAST AGAINST AND PERMANENTLY EXPOSED TO EARTH, WHERE MINIMUM COVER SHALL BE 3 IN.
35. CORROSIVE ENVIRONMENTS:
IN CORROSIVE ENVIRONMENTS OR OTHER SEVERE EXPOSURE CONDITIONS, AMOUNT OF CONCRETE PROTECTION SHALL BE
SUITABLY INCREASED, AND DENSENESS AND NONPOROSITY OF PROTECTING CONCRETE SHALL BE CONSIDERED, OR OTHER PROTECTION SHALL BE PROVIDED. "COVER" WHERE NOTED ON PLANS AND DETAILS IS NOT A MINIMUM, UNLESS NOTED AS "MIN." THE COVER SHALL BE AS NOTED WITH TOLERANCE.
36. MINIMUM DIAMETER OF BEND:
37. TOLERANCE FOR d AND MINIMUM CONCRETE COVER IN FLEXURAL MEMBERS, WALLS, AND COMPRESSION MEMBERS SHALL BE AS FOLLOWS:
EXCEPT THAT TOLERANCE FOR THE CLEAR DISTANCE TO FORMED SOFFITS SHALL BE MINUS 1/4 IN. AND TOLERANCE FOR COVER SHALL NOT EXCEED MINUS 1/3 THE MINIMUM CONCRETE COVER REQUIRED IN THE DESIGN DRAWINGS AND SPECIFICATIONS.
38. MAXIMUM CHLORIDE ION CONTENT FOR CORROSION PROTECTION OF REINFORCEMENT:
39. TOLERANCE FOR LONGITUDINAL LOCATION OF BEND AND ENDS OF REINFORCEMENT SHALL BE ± 2 IN., EXCEPT THE TOLERANCE SHALL BE ± 1/2 IN. AT THE DISCONTINUOUS ENDS OF BRACKETS AND CORBELS, AND ± 1 IN. AT THE DISCONTINUOUS ENDS OF OTHER MEMBERS.
40. REINFORCEMENT RESISTING EARTHQUAKE-INDUCED FLEXURAL AND AXIAL FORCES IN FRAME MEMBERS AND IN STRUCTURAL WALL BOUNDARY ELEMENTS SHALL COMPLY WITH ASTM A 706. ASTM A 615 GRADES 40 AND 60 REINFORCEMENT SHALL BE PERMITTED IN THESE MEMBERS IF:
A. THE ACTUAL YIELD STRENGTH BASED ON MILL TESTS DOES NOT EXCEED fy BY MORE THAN 18,000 PSI (RETESTS SHALL NOT EXCEED THIS VALUE BY MORE THAN AN ADDITIONAL 3000 PSI): AND B. THE RATION OF THE ACTUAL TENSILE STRENGTH TO THE ACTUAL YIELD STRENGTH IS NOT LESS THAN 1.25.
C. THE VALUE OF fyt FOR TRANSVERSE REINFORCEMENT INCLUDING SPIRAL REINFORCEMENT SHALL NOT EXCEED 60,000 PSI.
41. CONCRETE FLOOR FLATNESS SHALL BE A MINIMUM OF 1/4" : 10 FT. TYP. U.N.O.
42. WHERE CORROSION-RESISTANT REINFORCEMENT (CRR) IS SPECIFIED, USE MMFX2 REBAR ASTM A1035 GRADES 690 AND 830.
43. WELDING OF ELECTRICAL CONDUCTORS TO REINFORCING STEEL IS PROHIBITED WITHOUT THE APPROVAL OF THE ENGINEER OF RECORD.
44. PERFORMANCE OF SHOTCRETE SHALL BE PER ACI 506.2 SPECIFICATIONS.
CONCRETE NOTES
BAR SIZE MIN DIA.
#3 - #8 6db
#9 - #11 8db
#12 - #18 10db
d TOLERANCE
d ≤ 8" ± 3/8"
d > 8" ± 1/2"
MIN. CONC. COVER TOLERANCE
- 3/8"
- 1/2"
TYPE OF MEMBER
MAXIMUM WATER SOLUBLE
CHLORIDE ION (CI') IN CONCRETE,
PERCENT BY WEIGHT OF CEMENT
PRESTRESSED CONCRETE 0.06
0.15 1.00
REINFORCED CONCRETE EXPOSED TO CHLORIDE IN SERVICE
REINFORCED CONCRETE THAT WILL BE DRY OR PROTECTED FROM MOISTURE IN SERVICE OTHER REINFORCED CONCRETE CONSTRUCTION 0.30
1. ALL FRAMING LUMBER SHALL BE COAST REGION DOUGLAS FIR-LARCH & SHALL CONFORM TO THE FOLLOWING GRADES AS ESTABLISHED BY THE W.C.L.I.B. SAWN LUMBER, MACHINE STRESS-RATED OR MACHINE-EVALUATED LUMBER, SHALL BE
IDENTIFIED BY THE GRADE MARK OF LUMBER GRADING OR INSPECTION AGENCY THAT HAS BEEN APPROVED BY AN ACCREDITATION BODY THAT COMPLIES WITH DOC PS 20 OR EQUIVALENT.:
A. STUDS: (EXCEPT AS NOTED ON DRAWINGS)
a. 2"-4" THICK, 2"-4" WIDE, INTERIOR, NON-BEARING PARTITIONS, STANDARD GRADE. b. 2"-4" THICK, 5" AND WIDER, NO.2 OR BETTER DF.
B. JOISTS AND RAFTERS: (EXCEPT AS NOTED ON DRAWINGS)
a. 2"-4" THICK, 2"-4" WIDE, NO.2
b. 2"-4" THICK, 5" AND WIDER, NO.2
C. BEAMS AND HEADERS: (EXCEPT AS NOTED ON DRAWINGS)
a. 2"-4" THICK, 5" AND WIDER, NO.1
b. 5" AND THICKER, NO.1
D. POSTS: ALL POSTS NO.1
E. TOP PLATES: 2 X 4 NO.1 2 X 6 NO.2 OR BETTER
F. BLOCKING: STANDARD GRADE
G. SILL PLATES:
a. EXTERIOR AND SHEAR WALLS 2 X OR 3X NO.2 PRESSURE TREATED b. INTERIOR PARTITIONS 2 X 4 CONSTR. OR BETTER.
2. ALL FRAMING ANCHORS, CLIPS, STRAPS, HANGERS, ETC., SHALL BE MANUFACTURED BY SIMPSON COMPANY OR I.C.C.
APPROVED EQUAL WITH 5% TOLERANCE.
3. HY-TEK FASTENERS MAY BE USED AS AN APPROVED EQUAL IN LIEU OF COMMON, SHORT, BOX, SINKER NAILS, AND SIMPSON SDS SCREWS AS APPROVED IN ICC-ES ESR-2648 (LARR 25959 IN THE CITY OF LOS ANGELES).
4. ALL BEAM AND JOIST HANGERS SHALL BE THE FULL DEPTH OF THE MEMBER IT IS SUPPORTING.
5. ALL BEAM AND JOIST METAL HANGERS SHALL HAVE ALL HOLES FILLED PER MANUF. TO ACHIEVE MAX CAPACITY.
6. TYPICAL ROOF SHEATHING SHALL BE 5 PLY. WITH THICKNESS & PANEL INDEX LUMBER AS INDICATED ON THE DRAWINGS.
STAGGER SHEETS 4'-0". FACE GRAIN SHALL BE PERPENDICULAR TO THE SUPPORTS. PLYWOOD SHALL BE NAILED AS INDICATED ON THE DRAWINGS.
7. MAXIMUM UNFRAMED HOLES IN SHEATHING SHALL BE 3" IN DIAMETER. WHERE POSSIBLE, LOCATE HOLE IN WALL MIDWAY BETWEEN THE JOISTS. WHERE SQUARE HOLES ARE CUT, DO NOT RUN SAW BEYOND THE CORNER OF THE OPENING.
8. ALL WOOD SHEATHING SHALL BE APA RATED EXPOSURE 1 UNO. WHERE PLYWOOD IS PERMANENTLY EXPOSED TO WEATHER, OR USED IN DECKS, THE EXPOSURE RATING SHALL BE EXTERIOR. WOOD STRUCTURAL PANELS SHALL CONFORM TO THE REQUIREMENTS FOR THEIR TYPE IN DOC PS 1 OR PS 2. EACH PANEL OR MEMBER SHALL BE IDENTIFIED FOR GRADE AND GLUE TYPE BY THE TRADEMARKS OF AN APPROVED TESTING AND GRADING AGENCY. DIAPHRAGMS STRUCTURAL I U.N.O.
9. WHERE ROOF AND/OR FLOOR SHEATHING IS NAILED AT 2 1/2" O.C., ALL FRAMING INCLUDING BLOCKING SHALL BE 3X NOMINAL.
10. OSB IS AN ACCEPTABLE ALTERNATIVE TO PLYWOOD AT SHEAR WALLS, ROOF SHEATHING, AND FLOOR SHEATHING WHEN THE OWNER APPROVES THE SUBSTITUTION.
11. ALL EDGE NAILING ON SHEAR WALL PLY. SHALL MAINTAIN A 3/8" MIN. CLR. DISTANCE @ ALL BOUNDARY NAILING ON ROOF OR FLOOR PLYWOOD SHEATHING SHALL MAINTAIN A 3/8" MIN. CLR.
12. FASTENERS IN CONTACT WITH PRESERVATIVE-TREATED WOOD SHALL BE HOT-DIPPED ZINC-COATED GALVANIZED STEEL, STAINLESS STEEL, SILICON BRONZE OR COPPER. FASTENERS OTHER THAN NAIL, TIMBER RIVETS, WOOD SCREWS AND LAG
SCREWS SHALL BE PERMITTED TO BE OF MECHANICALLY DEPOSITED ZINC-COATED STEEL WITH COATING WEIGHTS IN ACCORDANCE WITH ASTM B 695, CLASS 55 MINIMUM. CONNECTORS THAT ARE USED IN EXTERIOR APPLICATIONS AND IN
CONTACT WITH PRESERVATIVE-TREATED WOOD SHALL HAVE COATING TYPES AND WEIGHTS IN ACCORDANCE WITH THE TREATED WOOD OR CONNECTOR MANUFACTURER'S RECOMMENDATIONS. IN THE ABSENCE OF MANUFACTURER'S RECOMMENDATIONS, A MINIMUM OF ASTM A 653, TYPE G185 ZINC-COATED GALVANIZED STEEL, OR EQUIVALENT, SHALL BE USED. EXCEPTION: PLAIN CARBON STEEL FASTENERS IN SBX/DOT AND ZINC BORATE PRESERVATIVE-TREATED WOOD IN AN INTERIOR, DRY ENVIRONMENT SHALL BE PERMITTED.
13. GRADE AND SPECIES OF ALL LUMBER MUST BE GRADE MARKED.
14. ALL DIAPHRAGMS AND SHEAR WALL NAILING SHALL UTILIZE COMMON NAILS OR GALVANIZED BOX.
15. ALL BOLTS SHALL BE DRILLED 1/32 TO 1/16" OVERSIZED.
16. ALL LUMBER SHALL BE KILN DRY TO 19% AND 15% FOR PLYWOOD MAX MOISTURE CONTENT.
17. WHERE ROUGH CARPENTRY IS EXPOSED TO WEATHER, IN GROUND CONTACT, PRESSURE-PRESERVATIVE TREATED, OR IN AREA OF HIGH RELATIVE HUMIDITY, PROVIDE FASTENERS WITH HOT-DIP ZINC COATING COMPLYING WITH ASTM A 153/A 153M OR TYPE 304 STAINLESS STEEL.
18. LAG SCREWS SHALL BE BORED AS FOLLOWS:
A. THE CLEARANCE HOLE FOOT THE SHANK SHALL HAVE THE SAME DIAMETER AS THE SHANK, AND THE SAME DEPTH OF PENETRATION AS THE LENGTH OF UNTHREADED SHANK.
B. THE LEAD HOLE FOR THE THREADED PORTION SHALL HAVE A DIAMETER EQUAL TO 40%-70% IN WOOD W/G < 0.5 AND A LENGTH EQUAL TO AT LEAST THE LENGTH OF THE THREADED PORTION. THE LARGER PERCENTILE IN EA. RANGE SHALL APPLY TO LAG SCREWS OF GREATER DIAMETERS. LEAD HOLES OR CLEARANCE HOLES SHALL NOT BE REQUIRED FOR 3/8" AND SMALLER DIAMETER LAG SCREWS LOADED PRIMARILY IN WITHDRAWAL IN WOOD W/ G < 0.5, PROVIDED THAT EDGE DISTANCES, END DISTANCES, AND SPACING ARE SUFFICIENT TO PREVENT UNUSUAL SPLITTING. THE THREADED PORTION OF THE LAG SCREW SHALL BE INSERTED IN ITS LEAD HOLE BY TURNING WITH A WRENCH, NOT BY DRIVING W/ A HAMMER.
SOAP OR OTHER LUBRICANT SHALL NOT BE USED ON THE LAG SCREWS OR IN THE LEAD HOLES TO FACILITATE INSERTION AND PREVENT DAMAGE TO THE SCREW.
D = UNTHREADED SHANK DIAMETER
S = UNTHREADED SHANK LENGTH
Dr = ROOT DIAMETER OF THREADED PORTION
T = THREAD LENGTH
W = WIDTH OF HEAD ACROSS FLATS
E = LENGTH OF TAPERED TIP
H = HEIGHT OF HEAD
M = NUMBER OF THREADS/INCH
ROUGH CARPENTRY NOTES
1. BLOCK SHALL BE MEDIUM WEIGHT UNITS CONFORMING TO ASTM C-90 GRADE N-1. USE UNITS OPEN ONE END, AND BOND BEAM UNITS AT HORIZONTAL REINFORCING. WHEN BLOCKS ARE EXPOSED OBTAIN APPROVAL OF SUBMITTAL FROM ARCHITECT.
UNITS SHALL ATTAIN A MINIMUM COMPRESSIVE STRENGTH AS REQUIRED TO MEET THE MASONRY COMPRESSIVE STRENGTH OF MASONRY f'm SPECIFIED ON THE PLANS AS FOLLOWS:
A. 1,900 PSI FOR SPECIFIED f'm UP TO 1,500 PSI
B. 2,800 PSI FOR SPECIFIED f'm UP TO 2,000 PSI
C. 3,750 PSI FOR SPECIFIED f'm UP TO 2,500 PSI
D. 4,800 PSI FOR SPECIFIED f'm UP TO 3,000 PSI
2. MIN. SPECIFIED COMPRESSIVE STRENGTH SHALL BE f'm = 2,000 PSI, UNLESS OTHERWISE SPECIFIED ON THE PLANS.
3. CEMENT: ASTM C-150, LOW ALKALI, TYPE I OR II PORTLAND CEMENT. (MASONRY CEMENT AND PLASTIC CEMENT SHALL NOT BE USED.)
4. MORTAR:
A. CONFORMING TO ASTM C-270, TYPE [S].
B. MIX PROPORTIONS SHALL CONFORM TO ASTM C-270.
C. AGGREGATES SHALL CONFORM TO ASTM C-144.
5. GROUT:
A. CONFORMING TO ASTM C-476.
B. ATTAINS THE MASONRY COMPRESSIVE STRENGTH f'm OR 2,000 PSI AT 28 DAYS, WHICHEVER IS GREATER.
C. MIX PROPORTIONS SHALL CONFORM TO ASTM C-476.
D. AGGREGATES SHALL CONFORM TO ASTM C-404.
E. USE COARSE GROUT IN GROUT SPACES 2 INCHES OR MORE IN WIDTH AND IN CELLS TO BE GROUTED SOLID.
6. MINIMUM LAP OF REINFORCING STEEL IN 12" CMU OR GREATER WALLS, OR #6 OR GREATER BARS SHALL BE 72 BAR DIAMETERS. BALANCE OF LAPS SHALL BE 48 BAR DIAMETERS OR A MINIMUM OF 2'-0".
7. MINIMUM GROUTING: SOLID GROUT ALL CELLS UNLESS NOTED OTHERWISE.
8. VERTICAL EXPANSION JOINTS SHALL BE PROVIDED AT 40'-0" o/c MAXIMUM. EXPANSION JOINT MATERIALS SHALL BE PER ASTM C90, D994, OR D1056 CLASS 2A1.
9. SPECIAL INSPECTION OF WORK IS REQUIRED FOR ALL MASONRY STRUCTURES PER TMS 402/ACI 530/ASCE 5 LEVEL B QUALITY ASSURANCE, UNLESS NOTED OTHERWISE ON THE DRAWINGS.
10. ALL BOLTS SHALL BE GROUTED IN PLACE WITH AT LEAST 1 INCH OF GROUT BETWEEN THE BOLT AND THE MASONRY.
11. THE CLEAR DISTANCE BETWEEN PARALLEL BARS SHALL NOT BE LESS THAN THE NOMINAL DIAMETER OF THE BARS, NOR LESS THAN 1 IN. (25.4mm).
12. IN COLUMNS AND PILASTERS, THE CLEAR DISTANCE BETWEEN VERTICAL BARS SHALL NOT BE LESS THAN ONE AND ONE-HALF TIMES THE NOMINAL BAR DIAMETER, NOR LESS THAN 11/2 IN. (38.1mm).
13. THE CLEAR DISTANCE LIMITATIONS BETWEEN BARS REQUIRED IN SECTIONS 1.13.3.1 AND 1.13.3.2 SHALL ALSO APPLY TO THE CLEAR DISTANCE BETWEEN A CONTACT LAP SPLICE AND ADJACENT SPLICES OR BARS.
14. GROUPS OF PARALLEL REINFORCING BARS BUNDLED IN CONTACT TO ACT AS A UNIT SHALL BE LIMITED TO TWO IN ANY ONE BUNDLE. INDIVIDUAL BARS IN A BUNDLE CUT OFF WITHIN THE SPAN OF A MEMBER SHALL TERMINATE AT POINTS AT LEAST 40 BAR DIAMETER APART.
15. REINFORCEMENT EMBEDDED IN GROUT SHALL HAVE A THICKNESS OF GROUT BETWEEN THE REINFORCEMENT AND MASONRY UNITS NOT LESS THAN 1/4 IN. (6.4mm) FOR FINE GROUT OR 1/2 IN. (12.7mm) FOR COARSE GROUT.
16. REINFORCING BARS SHALL HAVE A MASONRY COVER NOT LESS THAN THE FOLLOWING:
A. MASONRY FACE EXPOSED TO EARTH OR WEATHER: 2 IN. (50.8mm) FOR BARS LARGER THAN NO.5 (M #16); 11/2 IN. (38.1mm) FOR NO.5 (M #16) BARS OR SMALLER.
B. MASONRY NOT EXPOSED TO EARTH OR WEATHER: 11/2 IN. (38.1mm).
17. LONGITUDINAL WIRES OF JOINT REINFORCEMENT SHALL BE FULLY EMBEDDED IN MORTAR OR GROUT WITH A MINIMUM COVER OF 5/8 IN. (15.9mm) WHEN EXPOSED TO EARTH OR WEATHER AND 1/2 IN. (12.7mm) WHEN NOT EXPOSED TO EARTH OR WEATHER. JOINT REINFORCEMENT SHALL BE STAINLESS STEEL OR PROTECTED FROM CORROSION BY HOT-DIPPED
GALVANIZED COATING OR EPOXY COATING WHEN USED IN MASONRY EXPOSED TO EARTH OR WEATHER AND IN INTERIOR WALLS EXPOSED TO A MEAN RELATIVE HUMIDITY EXCEEDING 75 PERCENT. ALL OTHER JOINT REINFORCEMENT SHALL BE MILL GALVANIZED, HOT-DIP GALVANIZED, OR STAINLESS STEEL.
18. WALL TIES, SHEET-METAL ANCHORS, STEEL PLATES AND BARS, AND INSERTS EXPOSED TO EARTH OR WEATHER, OR EXPOSED TO A MEAN RELATIVE HUMIDITY EXCEEDING 75 PERCENT SHALL BE STAINLESS STEEL OR PROTECTED FROM CORROSION BY HOT-DIP GALVANIZED COATING OR EPOXY COATING. WALL TIES, ANCHORS, AND INSERTS SHALL BE MILL GALVANIZED, HOT-DIP GALVANIZED, OR STAINLESS STEEL FOR ALL OTHER CASES. ANCHOR BOLTS, STEEL PLATES, AND BARS NOT EXPOSED TO EARTH, WEATHER, NOR EXPOSED TO A MEAN RELATIVE HUMIDITY EXCEEDING 75 PERCENT, NEED NOT BE COATED.
19. REINFORCEMENT SHALL BE SUPPORTED AND FASTENED TOGETHER TO PREVENT DISPLACEMENTS BEYOND THE TOLERANCES ALLOWED BY SECTION 3.4 OF ACI 530.1 PRIOR TO GROUTING.
20. GROUT LIFTS SHALL NOT EXCEED 12.67 FEET WHEN THE MASONRY HAS CURED FOR 4 HOURS, THE GROUT SLUMP IS MAINTAINED BETWEEN 10 AND 11 INCHES AND NO INTERMEDIATE REINFORCED BOND BEAMS ARE PLACED BETWEEN THE TOP AND THE BOTTOM OF THE POUR HEIGHT. OTHERWISE, PLACE GROUT IN LIFTS NOT EXCEEDING 5 FEET. (SECTION 3.5 OF ACI 530.1)
21. PIPES AND CONDUITS EMBEDDED IN MASONRY SHALL NOTE REDUCE THE REQUIRED STRENGTH. (SECTION 1.16.2 OF ACI 530)
22. SUPPORT AND FASTEN REINFORCEMENT TOGETHER TO PREVENT DISPLACEMENT BEYOND THE TOLERANCES ALLOWED BY CONSTRUCTION LOADS OR BY PLACEMENT OF GROUT OR MORTAR.
23. COMPLETELY EMBED REINFORCING BARS IN GROUT IN ACCORDANCE WITH ARTICLE 3.5 ACI 350.
24. MAINTAIN CLEAR DISTANCE BETWEEN REINFORCING BARS AND ANY FACE OF MASONRY UNIT OR FORMED SURFACE, BUT NOT LESS THAN 1/4 IN. (6.4mm) FOR FINE GROUT OR 1/2 IN. (12.7mm) FOR COARSE GROUT.
25. SPLICE ONLY WHERE INDICATED ON THE PROJECT DRAWINGS, UNLESS OTHERWISE ACCEPTABLE. WHEN SPLICING BY WELDING, PROVIDE WELDS IN CONFORMANCE WITH THE PROVISIONS OF AWS D 1.4.
26. UNLESS ACCEPTED BY THE ARCHITECT/ENGINEER, DO NOT BEND REINFORCEMENT AFTER IT IS EMBEDDED IN GROUT OR MORTAR.
27. NONCONTACT LAP SPLICES - POSITION BARS SPLICED BY NONCONTACT LAP SPLICE NO FARTHER APART TRANSVERSELY THAN ONE-FIFTH THE SPECIFIED LENGTH OF LAP NOR MORE THAN 8 IN. (203mm).
28. TOLERANCES FOR THE PLACEMENT OF REINFORCING BARS IN WALLS AND FLEXURAL ELEMENTS SHALL BE ± 1/2 IN. (12.7mm) WHEN THE DISTANCE FROM THE CENTERLINE OF REINFORCING BARS TO THE OPPOSITE FACE OF MASONRY, d, IS EQUAL TO 8 IN. (203mm) OR LESS, ± 1 IN. (25.4mm) FOR d EQUAL TO 24 IN. (610mm) OR LESS BUT GREATER THAN 8 IN. (203mm), AND ± 11/4 IN. (31.8mm) FOR d GREATER THAN 24 IN. (610mm).
29. PLACE VERTICAL BARS WITHIN 2 IN. (50.8mm) OF THE REQUIRED LOCATION ALONG THE LENGTH OF THE WALL.
30. IF IT IS NECESSARY TO MOVE BARS MORE THAN ONE BAR DIAMETER OR A DISTANCE EXCEEDING THE TOLERANCE STATED
ABOVE TO AVOID INTERFERENCE WITH OTHER REINFORCING STEEL, CONDUITS, OR EMBEDDED ITEMS, NOTIFY THE ARCHITECT/ENGINEER FOR ACCEPTANCE OF THE RESULTING ARRANGEMENT OF BARS.
31. FOUNDATION DOWELS THAT INTERFERE WITH UNIT WEBS ARE PERMITTED TO BE BENT TO A MAXIMUM OF 1 IN. (25mm) HORIZONTALLY FOR EVERY 6 IN. (152mm) OF VERTICAL HEIGHT.
32. EMBED HEADED AND BENT-BAR ANCHOR BOLTS LARGER THAN 1/4 IN. (6.4mm) DIAMETER IN GROUT THAT IS PLACED IN ACCORDANCE WITH ARTICLE 3.5 A AND ARTICLE 3.5 B ACI 350. ANCHOR BOLTS OF 1/4 IN. (6.4mm) DIAMETER OR LESS ARE PERMITTED TO BE PLACED IN GROUT OR MORTAR BED JOINTS THAT HAVE A SPECIFIED THICKNESS OF AT LEAST 1/2 IN. (12.7mm) THICKNESS.
33. MAINTAIN CLEAR DISTANCE BETWEEN ANCHOR BOLTS AND ANY FACE OF MASONRY UNIT OR FORMED SURFACE OF AT LEAST 1/4 IN. (6.4mm) WHEN USING FINE GROUT, AND OF AT LEAST 1/2 IN. (12.7mm) WHEN USING COARSE GROUT.
34. PLACE ANCHOR BOLTS WITH A CLEAR DISTANCE BETWEEN PARALLEL ANCHOR BOLTS NOT LESS THAN THE NOMINAL DIAMETER OF THE ANCHOR BOLT, NOR LESS THAN 1 IN. (25.4mm).
35. OWNER WILL ENGAGE A QUALIFIED INDEPENDENT TESTING AGENCY TO PERFORM PRECONSTRUCTION TESTING INDICATED BELOW. RETESTING OF MATERIALS THAT FAIL TO COMPLY WITH SPECIFIED REQUIREMENTS SHALL BE DONE AT CONTRACTOR'S EXPENSE.
A. CONCRETE MASONRY UNIT TEST: FOR EACH TYPE OF UNIT REQUIRED, ACCORDING TO ASTM C 140 FOR COMPRESSIVE STRENGTH.
B. MORTAR TEST (PROPERTY SPECIFICATION): FOR EACH MIX REQUIRED, ACCORDING TO ASTM C 109/C 109M FOR COMPRESSIVE STRENGTH[, ASTM C 1506 FOR WATER RETENTION, AND ASTM C 91 FOR AIR CONTENT].
C. MORTAR TEST (PROPERTY SPECIFICATION): FOR EACH MIX REQUIRED, ACCORDING TO ASTM C 780 FOR COMPRESSIVE STRENGTH.
D. GROUT TEST (COMPRESSIVE STRENGTH): FOR EACH MIX REQUIRED, ACCORDING TO ASTM C 1019.
CONCRETE MASONRY UNIT (CMU) NOTES
Structural Engineering
Stonecap, Inc.
1809 S Street, Ste. 101-277
Sacramento, CA 95811
© 2024 Stonecap, Inc.
SHELTER II
AT EAST BEAMER
1901 EAST BEAMER
WOODLAND, CA
95776
JOB NO.
DRAWN
DATE
SCALE
FILENAME
KEYPLAN
REVISIONS
9/26/2024 5:18:47
PM
Author
23035
S001
STRUCTURAL
NOTES
PROGRESS SET
NOT FOR
CONSTRUCTION
1. PROVIDE STRUCTURAL STEEL COMPLYING WITH THE FOLLOWING ASTM STANDARD SPECIFICATIONS, UNLESS NOTED OTHERWISE:
A. WIDE FLANGE AND WT SECTIONS.......................... ASTM A992, GRADE 50 B. ANGLES AND CHANNELS........................................ ASTM A36 C. PLATES................................................................... ASTM A36 D. PIPES..................................................................... ASTM A53, GRADE B (35 KSI) E. HOLLOW STRUCTURAL SECTIONS........................... ASTM A500, GRADE B (46 KSI) F. STRUCTURAL STEEL NOTED THUS (50)................ ASTM A572 OR A992, GRADE 50 G. ANCHOR BOLTS.....................................................ASTM F1554, GRADE 36 H. BOLTS (SS)............................................................ ASTM F593 I. ANCHOR BOLTS IN FRAME.................................... ASTM F1554, GRADE 105 J. THREADED ROUND STOCK (STEEL FRAMING)........ASTM A325 K. REINFORCING STEEL............................................... SEE REINFORCING STEEL SECTION L. ALL STIFFENER PLATES, GUSSETS, AND BASE PLATES PART OF A MOMENT FRAME OR BRACE FRAME.......................ASTM A-572, GRADE 50
2. WHERE NOTED ON PLANS AS (SS), SHALL BE STAINLESS STEEL 304 CONDITION (A). STAINLESS STEEL MECHANICAL TUBING SHALL BE PER ASTM A554-11 STANDARD SPECIFICATION, AND ALL STAINLESS BARS AND SHAPES SHALL BE PER ASTM A276-10 STANDARD SPECIFICATIONS. FURNISH READILY IDENTIFIABLE STRUCTURAL STEEL COMPLYING WITH CBC.
3. HIGH STRENGTH BOLTS, NUTS, AND WASHERS:
A. TYPE: PROVIDE HIGH STRENGTH BOLTS, NUTS, AND WASHERS COMPLYING WITH ASTM A325, UNLESS NOTED OTHERWISE.
HIGH STRENGTH BOLTS SHALL BE BEARING WITH THREADS INCLUDED IN SHEAR PLANE (A325-N), UNLESS NOTED OTHERWISE. PROVIDE SLIP-CRITICAL HIGH STRENGTH BOLTS (A325-SC) FOR SEISMIC MOMENT FRAME BEAM-TO-COLUMN CONNECTIONS, UNLESS NOTED OTHERWISE.
B. INSTALLATION: INSTALL HIGH STRENGTH BOLTS COMPLYING WITH "SPECIFICATION FOR STRUCTURAL JOINTS USING HIGHSTRENGTH BOLTS" AND CBC SECTION 2204.2.
C. TIGHTENING: TIGHTEN A325-N BOLTS TO A SNUG TIGHT CONDITION. TIGHTEN A325-SC BOLTS TO AT LEAST THE MINIMUM TENSION USING ONE OF THE FOLLOWING METHODS: TURN-OF-NUT, CALIBRATED WRENCH, OR DIRECT TENSION INDICATOR TIGHTENING.
4. WELDING:
A. WELDING STANDARD: AWS D1.1 AND AISC 360 (AWS D1.8 AND AISC 341 FOR SEISMIC FORCE RESISTING SYSTEM) B. WELDING PROCESS: WELDING SHALL BE DONE BY ELECTRIC ARC USING E70XX ELECTRODES UNLESS NOTED OTHERWISE.
SUBMERGED ARC PROCESS WITH AUTOMATIC WELDING (SAW-1) MAY BE USED AS AN ALTERNATE.
C. PRE-QUALIFIED & NON PRE-QUALIFIED WELDS: WELDS SHALL BE PRE-QUALIFIED COMPLYING WITH WELDING STANDARD.
WHERE NON PRE-QUALIFIED WELDS ARE SPECIFICALLY INDICATED, QUALIFY BY TESTING AND PROCEDURE QUALIFICATION TEST RECORD COMPLYING WITH WELDING STANDARD.
D. WELDER CERTIFICATION: WELDERS SHALL BE CERTIFIED AS REQUIRED BY GOVERNING CODE AUTHORITY.
E. SHOP WELDING INCLUDING ULTRASONIC TESTING OF COMPLETE PENETRATION GROOVE WELDS WELDED IN SHOP:
PERFORM ON PREMISES OF AN APPROVED FABRICATOR COMPLYING WITH CBC SECTION 1704.2.5.2.
F. MINIMUM FILLET WELD SIZE: PROVIDE MINIMUM FILLET WELD COMPLYING WITH AISC 360 SECTION J2 AND TABLE J2.4 UNLESS A LARGER WELD IS INDICATED ON DRAWINGS.
G. SHOP AND FIELD WELDING INDICATION ON DRAWINGS: NO ATTEMPT IS MADE TO DIFFERENTIATE BETWEEN SHOP AND FIELD WELDED CONNECTIONS.
5. WELD INSPECTION:
A. LEAD WELDING INSPECTOR CERTIFICATION: LEAD WELDING INSPECTOR SHALL BE A CERTIFIED WELDING INSPECTOR (CWI) COMPLYING WITH AWS-QC1 STANDARDS, SHALL BE RECOGNIZED BY THE BUILDING OFFICIAL AS A REGISTERED DEPUTY
INSPECTOR FOR STRUCTURAL STEEL WELDING (ICC CERTIFICATION) AND SHALL POSSES A MINIMUM LEVEL OF UT LEVEL II CERTIFICATION.
B. OTHER WELDING INSPECTORS: WELDING INSPECTORS PERFORMING VISUAL INSPECTION UNDER THE SUPERVISION OF
THE LEAD WELDING INSPECTOR SHALL POSSES ICC CERTIFICATION, AND PERSONS PERFORMING NON-DESTRUCTIVE TESTING SHALL POSSES UT LEVEL II CERTIFICATION. FOUR NON-CERTIFIED WELDING INSPECTORS MAXIMUM SHALL BE UNDER THE SUPERVISION OF A CWI.
C. WELD INSPECTIONS: PROVIDE WELD INSPECTIONS AS REQUIRED BY CBC SECTION 1705.2 AND AISC 360 CHAPTER N (AISC 341 CHAPTER J FOR SEISMIC FORCE RESISTING SYSTEM). SEE STATEMENT OF SPECIAL INSPECTION AND QUALITY ASSURANCE SECTION.
6. THE STRUCTURAL STEEL FABRICATOR SHALL FURNISH SHOP DRAWINGS OF ALL STEEL FOR THE ENGINEERS REVIEW PRIOR TO FABRICATION. ALL STEEL FABRICATION SHALL BE PERFORMED IN A SHOP APPROVED BY THE BUILDING DEPARTMENT.
7. EXCEPT WHERE ENCASED IN CONCRETE, MASONRY, OR SPRAYED-ON FIREPROOFING, ALL STEEL SHALL BE PRIMERED UNLESS NOTED OTHERWISE ON THE DRAWINGS. PAINTING OF STRUCTURAL STEEL MEMBERS SHALL COMPLY WITH THE REQUIREMENTS CONTAINED IN AISC 360.
8. OPENINGS SHALL NOT BE PLACED IN STEEL MEMBERS UNLESS SPECIFICALLY DETAILED. STEEL MEMBERS SHALL BE SHORED WHEN PERMISSIBLE HOLES ARE CUT WITH A TORCH AFTER STEEL IS ERECTED. THE SHORES SHALL REMAIN IN PLACE UNTIL THE STEEL TEMPERATURE HAS RETURNED TO AIR TEMPERATURE.
9. STRUCTURAL STEEL SHALL BE DELIVERED TO THE JOB SITE FREE OF EXCESSIVE RUST, MILL SCALE, GREASE, ETC. AND SHALL BE PRIMED.
10. WHERE WELDING TO EXISTING BEAMS ARE SHOWN, IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE AND PROVIDE ADEQUATE SHORING OF EXISTING BEAMS FOR LOSS OF STRENGTH DUE TO HEAT DURING WELDING.
11. NON-SHRINK GROUTS OR DRY-PACKS SHALL BE 6000 PSI MIN. ASTM C109 W/ SPECIAL INSPECTION REQUIRED TYP.
12. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL MEET THE MINIMUM SPECIFICATIONS IN THE AISC CODE OF STANDARD PRACTICE CHAPTER 10 UNLESS NOTED OTHERWISE ON THE ARCHITECTURAL DRAWINGS.
13. DEMAND CRITICAL WELDS: WELDS DESIGNATED AS DEMAND CRITICAL SHALL BE MADE WITH FILLER METALS MEETING THE REQUIREMENTS SPECIFIED IN AWS D1.8M CLAUSE 6.3.
IN ADDITION TO THE ABOVE REQUIREMENTS, AWS D1.8/D1.8M REQUIRES, UNLESS OTHERWISE EXEMPTED FROM TESTING, THAT
ALL DEMAND CRITICAL WELDS ARE TO BE MADE WITH FILLER METALS RECEIVING HEAT INPUT ENVELOPE TESTING THAT ACHIEVE THE FOLLOWING MECHANICAL PROPERTIES IN THE WELD METAL:
STRUCTURAL STEEL NOTES
PROPERTY
70 KSI (480 MPa)
YIELD STRENGTH, KSI (MPa) 58 (400) MIN.
CLASSIFICATION
80 KSI (550 MPa)
68 (470) MIN.
USER NOTE: AWS D1.8/D1.8M REQUIRES THAT ALL SEISMIC FORCE RESISTING SYSTEM WELDS ARE TO BE MADE WITH FILLER METALS CLASSIFIED USING AWS A5 STANDARDS THAT ACHIEVE THE FOLLOWING MECHANICAL PROPERTIES.
TENSILE STRENGTH, KSI (MPa) 70 (480) MIN. 80 (550) MIN.
ELONGATION, % 22 MIN. 19 MIN.
CVN TOUGHNESS, ft-lb (J) 20 (27) MIN. @ 0°F (-18°C)
a.
a. FILLER METALS CLASSIFIED AS MEETING 20 ft-lb (27 J) MIN. AT A TEMPERATURE LOWER THAN 0°F (-18°C) ALSO MEET THIS REQUIREMENT.
PROPERTY
70 KSI (480 MPa)
YIELD STRENGTH, KSI (MPa) 58 (400) MIN.
CLASSIFICATION
80 KSI (550 MPa)
68 (470) MIN.
MECHANICAL PROPERTIES FOR DEMAND CRITICAL WELDS
TENSILE STRENGTH, KSI (MPa) 70 (480) MIN. 80 (550) MIN.
ELONGATION, % 22 MIN. 19 MIN.
CVN TOUGHNESS, ft-lb (J) 40 (54) MIN. @ 70°F (20°C)
b., c.
b. FOR LAST OF +50°F (+10°C). FOR LAST LESS THAN +50°F (+10°C), SEE AWS D1.8/D1.8M SUBCLAUSE 6.3.6. c. TESTS CONDUCTED IN ACCORDANCE WITH AWS D1.8/D1.8M ANNEX A MEETING 40 ft-lb (54 J) MIN. AT A TEMPERATURE LOWER THAN +70°F (+20°C) ALSO MEET THIS REQUIREMENT.
Structural Engineering
Stonecap, Inc.
1809 S Street, Ste. 101-277
Sacramento, CA 95811
© 2024 Stonecap, Inc.
SHELTER II
AT EAST BEAMER
1901 EAST BEAMER
WOODLAND, CA
95776
JOB NO.
DRAWN
DATE
SCALE
FILENAME
KEYPLAN
REVISIONS
9/26/2024 5:18:47
PM
Author
23035
S002
STRUCTURAL
NOTES
PROGRESS SET
NOT FOR
CONSTRUCTION
BEAM & JOISTS SCHEDULE
LABEL
16" TRUSSES
SIZE
@24"OC
FB-1 - -
FB-2 - -
NOTES:
SPACING
RT-1
RJ-1 2X6 @16"OC
FB-3 - -
COLUMN SCHEDULE
NOTES:
MARK COLUMN SIZE BASE PLATE ANCHOR BOLTS LAYOUT COMMENTS C1 HSS 4x4x1/4 8" SQ. X 1/2" THK (4) 3/4"⌀X8" EMB A -
C2 - 16" SQ. X 1" THK B -
C3 - 18" SQ. X 1" THK (4) PAB9X12" EMB B -
'X''X'
'X' TYP
'X' = 1½" FOR AB ≤ 1"⌀
'X' = 2" FOR AB > 1"⌀
'X' TYP
'X' TYP
'X' TYP
EQ EQ
'X' TYP
EQ EQ
'X''X'
EQ EQ
A B C D E
C3B - (4) PAB8X12" EMB B -
C4 - (4) PAB9X12" EMB B -
C4B - (4) PAB8X12" EMB B -
18" SQ. X 1" THK
18" SQ. X 1" THK
18" SQ. X 1" THK
(4) 3/4"⌀X12" EMB
Structural Engineering
Stonecap, Inc.
1809 S Street, Ste. 101-277
Sacramento, CA 95811
© 2024 Stonecap, Inc.
SHELTER II
AT EAST BEAMER
1901 EAST BEAMER
WOODLAND, CA
95776
JOB NO.
DRAWN
DATE
SCALE
FILENAME
KEYPLAN
REVISIONS
9/26/2024 5:18:48
PM
Author
23035
S003
SCHEDULES
SHEAR WALL SCHEDULE
SW- MIN. MUD SILL
STUD/BLKG @
ADJOINING
PANEL EDGES
PERIODIC
SPECIAL
INSPECTION APA RATED OSB
EDGE NAILING
(EN)
FIELD NAILING
(FN)
FASTENERS @
2X SOLE PLT TO
BLKG
2X MUDSILL
ANCHOR
3X MUDSILL
ANCHOR
A35 OR LTP4
BLKG TO TOP PL
SW1 2X 2X NO 1/2" STRUC 1 8d @6"OC 12"OC 16d @9"OC 5/8"X10" @4'-0" 5/8"X12" @4'-0" 19"OC MAX SW2 3X 3X NO 1/2" STRUC 1 8d @4"OC 12"OC 16d @6"OC 5/8"X10" @1'-8" 5/8"X12" @4'-0" 12" OC MAX SW3 3X 3X YES 1/2" STRUC 1 8d @3"OC 12"OC 16d @5"OC 5/8"X10" @1'-4" 5/8"X12" @3'-5" 9"OC MAX SW4 3X 3X YES 1/2" STRUC 1 8d @2"OC 12"OC 16d @3"OC N/A 5/8"X12" @2'-7" 7"OC MAX SW5 3X 3X YES 1/2" STRUC 1 10d @2"OC 12"OC SDS25600 @6"OC N/A 5/8"X12" @2'-2" 6"OC MAX SW6 3X 3X YES 1/2" STRUC 1
BOTH SIDES
8d @3"OC BOTH
SIDES
12"OC SDS25600 @6"OC N/A 5/8"X12" @1'-8" LTP4 @7"OC
SW7 3X 3X YES 1/2" STRUC 1
BOTH SIDES
8d @2"OC BOTH
SIDES
8" OC SDS25600 @4"OC N/A 5/8"X12" @1'-3" LTP4 @5"OC
SW8 3X 3X YES 1/2" STRUC 1
BOTH SIDES
10d @2"OC BOTH
SIDES
8" OC SDS25600 @3"OC N/A 5/8"X12" @1'-0" LTP4 @4"OC
HOLD DOWN SCHEDULE
MARK HOLD DOWN SIZE
MIN. WOOD
MEMBER
THICKNESS POST FASTENERS FDN BOLT SIZE
H1 SIMPSON-HDU2 (2) 2X4 (6) SDS 1/4"X2 1/2" SSTB24
H2 SIMPSON-HDU4 4X4 (10) SDS 1/4"X2 1/2" 5/8" DIA.
H3 SIMPSON-HDU5 4X4 (14) SDS 1/4"X2 1/2" 5/8" DIA.
H4 SIMPSON-HDU8 4X4 (20) SDS 1/4"X2 1/2" 7/8" DIA.
H5 SIMPSON-HDU11 4X6 (30) SDS 1/4"X2 1/2" 1" DIA.
H6 SIMPSON-HDU11 4X8 (30) SDS 1/4"X2 1/2" 1" DIA.
H7 SIMPSON-HDU14 6X6 (36) SDS 1/4"X2 1/2" 1" DIA.
S1 SIMPSON-MST37 (2) 2X4 (22) 16d -
S2 SIMPSON-MST48 (2) 2X4 (34) 16d -
S3 SIMPSON-MST60 (2) 2X4 (48) 16d -
S4 SIMPSON-CMST12 6X6 (86) 16d -
S5 SIMPSON-MSTC48B3 (2) 2X6 (38) 16d -
CONTINUOUS FOOTING SCHEDULE
Type Mark Width Foundation Thickness Long Reinforcing Trans Reinforcing WF2.0 2'-0" 1'-6" (3)#5 T&B #5@12"OC T&B
HEADER SCHEDULE
WIDTH
HEADER (LOAD
BEARING)
HEADER
(NON-LOAD
BEARING) JACK STUD TRIMMER
4'-0" 6X4 6X4 (1) 2X6 (1) 2X STUD
6'-0" 6X8 6X6 (2) 2X6 (1) 2X STUD
8'-0" 6X10 6X8 (3) 2X6 (2) 2X STUD
10'-0" 6X12 6X10 (4) 2X6 (1) 4X STUD
12'-0" 6X14 6X12 (5) 2X6 (2) 2X STUD
LOAD BEARING SCHEDULE
LEVEL SIZE & SPACING MAX HEIGHT COMMENTS
1 2X6@16"OC 12'-0"
1 2X6@12"OC 20'-0"
ISOLATED FOOTING SCHEDULE
Mark
SIZE
Depth
REINFORCING
CommentsWidth Length EW Bottom EW Top
2'-0" <varies>
F3.0 3'-0" 3'-0" 1'-6" 4-#5 EW
PROGRESS SET
NOT FOR
CONSTRUCTION
A
5 12
S300
___________
11 S300
___________
12 S300
___________
11 S300
___________
11 S300
___________
11 S300
___________
5" THK SLAB ON GRADE W/
#4 @18"OC EW AT MIDHEIGHT
TYP
BCE
E
FF
GG
HKL
12346789 10 11 12
D
12 S300
___________
12 S300
___________
12 S300
___________
11 S300
___________
11 S300
___________ 11
S300
___________ 11
S300
11 ___________
S300
11 ___________
S300
___________
11 S300
___________
11 S300
___________
11 S300
___________
11 S300
___________
12 S300
___________
12 S300
___________
12 S300
___________
11 S300
___________ 11
S300
___________
J
F3.0
F3.0
F3.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0WF2.0
WF2.0WF2.0
WF2.0WF2.0
WF2.0WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
WF2.0
C1
C1
6x6
TYP. (8) PLACES
TYP. (7) PLACES
6x6
TYP. U.N.O.
TYP. (12) PLACES
F3.0
C1
F3.0
C1
WF2.0
WF2.0
WF2.0
TYP. (8) PLACES
TYP. (4) PLACES
S300
15 S300
15 S300
15 S300
15 H1 H1
H1
H1
H1
H1 H1
H1
H1
H1
H1
H1
H1
H1
H1 H1 H1
H1
H1
H1
H1 H1 H1 H1
H1 H1
H1
H1
H1
H1 H1 H1
SW1
10'-0"
SW1
10'-0"
SW1
17'-6"
SW1
19'-7"
SW1
22'-3"
SW1
44'-7"
SW1
17'-0"
SW1
19'-7"
SW1
35'-11"
SW1
35'-5"
SW1
20'-0"
SW1
21'-8"
23'-2"
SW1 SW1
14'-0"
H2
H2
9'-7"
SW3
H1
H1
31'-1"
SW1
31'-1"
SW1
H1
H1
H1
H1
9'-11"
SW4
H1
H1
SW2
17'-9"
H1
H1
H1
H1
SW1
15'-9"
SW1
7'-3"
SW1
12'-6"
SW1 (FTAO)
20'-0"
SW1 (FTAO)
15'-0"
H1
H1
H1
SW1
11'-3"
H1
20'-9"
SW1
FOUNDATION PLAN NOTES:
1. SEE S001 FOR GENERAL STRUCTURAL NOTES
2. SEE S001 FOR DESIGN SOIL BEARING PRESSURE, ETC.
3. AT EXTERIOR STUD WALLS WITH NO SHEAR WALL DESIGNATION, USE 5/8" ∅ ANCHOR BOLTS @
48" O.C.
4. SEE ARCH. FOR ALL DIMENSIONS & CONDITIONS NOT SHOWN.
5. PRIOR TO THE CONTRACTOR REQUESTING A BUILDING DEPT. FOUNDATION INSPECTION, THE SOILS ENGINEER SHALL ADVISE THE BUILDING OFFICIAL IN WRITING THAT:
A. THE BUILDING PAD WAS PREPARED IN ACCORDANCE WITH THE SOILS REPORT &
ADDENDUM LETTER
B. THE UTILITY TRENCHES HAVE BEEN PROPERLY BACK FILLED & COMPACTED.
C. THE FOUNDATION EXCAVATIONS COMPLY WITH THE INTENT OF THE SOILS REPORT.
6. ALL HOLDOWNS AND ANCHOR BOLTS AT SHEARWALL SHALL BE SET IN PLACE BY TEMPLATE PRIOR TO FOUNDATIONS INSPECTION AND RETIGHTENED PRIOR TO COVERING OF WALLS.
7. TYPICAL CONCRETE SLAB ON GRADE SHALL BE 5" THICK WITH #4 @ 18"O.C. EA. WAY MID HT.
OVER A 6-MIL MINIMUM POLYETHYLENE VAPOR RETARDER OVER 6" OF CRUSHED ROCK.
RECOMPACT SOILS PER THE RECOMMENDATIONS OF THE SOILS REPORT. MAXIMUM SPACING OF THE CONTROL JOINTS SHALL BE 10'-0" EA. WAY.
8. VAPOR RETARDER JOINTS SHOULD BE LAPPED NOT LESS THAN 6 INCHES AND SHALL BE PLACED BETWEEN THE BASE COURSE AND THE SOG.
9. ALL FOOTINGS ARE CENTERED UNDER COLUMNS AND BEARING WALLS UNLESS NOTED OTHERWISE ON PLANS AND DETAILS.
10. SEE ARCHITECTURAL PLANS FOR LOCATIONS OF ALL WALL OPENINGS, SLOPED AND
DEPRESSED SLABS, CONCRETE CURBS, ADDITIONAL EMBEDDED ITEMS NOT SHOWN ON THESE DRAWINGS. VERIFY ALL BUILDING DIMENSIONS, SLOPES AND DEPRESSED SLAB DIMENSIONS WITH ARCHITECTURAL PLANS BEFORE BEGINNING WORK. REPORT ANY DISCREPANCIES TO THE ARCHITECT FOR RESOLUTION.
11. SEE GENERAL NOTES AND SPECIFICATIONS FOR SPECIAL GRADING REQUIREMENTS UNDER FOOTINGS.
12. COLUMNS ARE ONE SIZE FROM FOUNDATION TO ROOF UNLESS OTHERWISE NOTED ON PLANS
13. ALL DIMENSIONS SHOWN ARE TO EDGE OF CONCRETE SLAB, CENTER OF INTERIOR WALL, OR CENTERLINE OF POST OR COLUMN. REFER TO ARCHITECTURAL PLANS FOR OTHER DIMENSIONS.
14. U.N.O. MINIMUM REINFORCEMENT OF ALL 8" MASONRY BLOCK WALLS SHALL BE #5 VERTICAL BARS @ 16"O.C. CENTERED IN WALL, AND #4 HORIZONTAL BARS @ 24"O.C. REFER TO PLANS AND DETAILS FOR ADDITIONAL REINFORCEMENT REQUIREMENTS. SPECIAL INSPECTION REQUIRED. SOLID GROUT ALL CELLS.
15. ALL COLUMNS ARE CENTERED ON THE GRID LINES UNLESS NOTED OTHERWISE.
16. ALL CONCRETE FLOORS TO BE FLAT U.N.O.
17. NEW TYPICAL CONTINUOUS FOOTINGS ARE 18" WIDE X 18" DEEP BELOW LOWEST ADJACENT GRADE WITH (2) #4 T&B (4) TOTAL, U.N.O.
18. SURFACE WATER SHALL DRAIN AWAY FROM THE BUILDING. COORDINATE WITH CIVIL & LANDSCAPE.
19. CONTRACTOR SHALL COORDINATE ALL UNDERGROUND UTILITY WORK TO AVOID CONFLICTS WITH FOOTINGS.
20. CONTRACTOR SHALL SUBMIT PROPOSED FIRE RISER, CONDUIT, PIPING SLEEVE LOCATION FOR ENGINEER'S REVIEW PRIOR TO FOOTING CONSTRUCTION.
21. SEE ARCH'L AND CIVIL DRAWINGS FOR LOCATION OF MOISTURE BARRIER, CURBS, TRASH ENCLOSURES, EXTERIOR SLABS, DRAINAGE, RAMPS, WALKS, ETC.
22. FOR FOOTINGS OUTSIDE THE BUILDING ENVELOPE, COORDINATE TOP OF FOOTING ELEVATION WITH THE STRUCTURAL DETAILS AND WITH CIVIL AND LANDSCAPE.
23. BUILDING SLAB IS NOT DESIGNED TO SUPPORT CRANE LOADS, CONCRETE MIXING TRUCKS, OR OTHER SPECIFIC CONSTRUCTION LOADING. IF SUCH LOADS OCCUR, THE CONTRACTOR SHALL
BE RESPONSIBLE FOR UPGRADING THE SLAB THICKNESS AND PROVIDING REINFORCING AS REQUIRED. ANY DAMAGE CAUSED TO THE SLAB SHALL BE REPAIRED AT THE CONTRACTOR'S EXPENSE PER THE OWNER'S REQUEST.
24. EXCAVATIONS SHALL BE MADE IN COMPLIANCE WITH CAL/OSHA REGULATIONS.
25. BACKFILLING OF WALLS WITH RETAINED SOIL SHALL BE OF NO-EXPANSIVE GRANULAR FILL IN ACCORDANCE WITH THE SOILS REPORT. WALLS RETAINING SOIL SHALL NOT BE BACKFILLED PRIOR TO PLACING SLAB ON GRADE AND SECOND FLOOR SLAB.
26. WF#.# INDICATES FOOTING MARK, FOR SIZE SEE SCHEDULE SHEET S003.
27. SW# INDICATES SHEAR WALL MARK, SEE SCHEDULE SHEET S003.
28. INDICATES A HOLDOWN MARK, SEE SCHEDULE SHEET S003. HOLDDOWNS SHOWN ON FOUNDATION PLAN ARE SAME HOLDDOWNS SHOWN ON 2ND FLOOR FRAMING.
29. INDICATES SIMPSON ATS HOLDDOWN. SEE ATS SHEETS FOR ID AND DETAILS & 6/S300
FOR FOUNDATION DETAILS
30. WWO# INDICATES WALL WITH OPENING PER DETAIL 7/S603
31. S-------S INDICATES STEPPED FOOTING PER DETAIL 15/S300 H# #
FRAMING PLAN NOTES:
1. FOR GENERAL STRUCTURAL NOTES SEE S001
2. FOR HEADERS CALLED OUT ON PLAN PROVIDE 2X TRIMMER @ 7¼ OR LESS HEADER; (2) 2X TRIMMER @ 9½ OR GREATER
3. ALL LOAD BEARING DEMISING WALLS TO BE 2 X 6 STUDS @ 16" O.C., U.N.O.
4. ALL EXTERIOR WALLS TO BE 2 X 6 STUDS @ 16" O.C., U.N.O.
5. EXTERIOR WALLS WITHOUT SHEARWALL SHEATHING SHALL HAVE SUBSTRATE SHEATHING PER ARCHITECTURAL DRAWINGS.
6. FOR TYPICAL STUD WALL FRAMING SEE S600
7. SEE DETAIL 10/S600 FOR ROUGH OPENINGS AROUND PTAC UNITS
8. PROVIDE MULTIPLE STUDS UNDER MULTIPLE JOISTS AND GIRDER TRUSSES (GT)
9. COLUMNS ARE CALLED OUT AT THE BASE LEVEL OF COLUMN AND CONTINUOUSLY STACK TO THE ROOF OR UNTIL IT IS NO LONGER SHOWN ON PLANS.
10. "C" = INDICATES CAMBER BETWEEN SUPPORTS ONLY @ GLUED, LAMINATED BEAMS. (i.e. NO CAMBER @ CANTILEVERS)
11. PROVIDE BOUNDARY NAILING ALONG ALL STRUT MEMBERS, INTERIOR SHEAR WALLS, AND INTERIOR LATERAL FRAMES U.N.O.
12. SEE ARCH. FOR ALL DIMENSIONS & CONDITIONS NOT SHOWN.
13. TYPICAL FLOOR SHEATHING SHALL BE 23/32" APA RATED SHEATHING, STURD-I-FLOOR, OR SINGLE FLOOR (EXPOSURE 1) (40/20) W/ 10d COMMON NAILS @ 6"O.C. BOUNDARIES & CONT.
PANEL EDGES, 6"O.C. OTHER PANEL EDGES, AND 12"O.C. FIELD NAILING. (UN-BLOCKED, T&G @
UNSUPPORTED PANEL EDGES)
14. UNLESS SPECIFICALLY NOTED ON THE PLANS, FRAMING SHALL NOT BE CUT OR RELOCATED WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. CONTRACTOR SHALL OBTAIN APPROVAL OF JOIST MFR. SHOP DRAWINGS FROM BOTH MECHANICAL AND STRUCTURAL ENGINEERS PRIOR TO ERECTION OF JOIST FRAMING.
15. ALL MULTIPLE JOISTS SHALL HAVE EACH JOIST NAILED TO THE ADJACENT ONE WITH 16d @ 16"O.C. STAGGERED.
16. ALL MULTIPLE STUDS SHALL HAVE EACH STUD NAILED TO THE ADJACENT ONE WITH SOLE PLATE NAILING PER SHEAR WALL SCHEDULE, 10d @9"O.C. STAGGERED MINIMUM.
17. FOR HEADER SIZES NOT NOTED, SEE SCHEDULE ON SHEET S003.
18. SW# INDICATES SHEAR WALL MARK, SEE SCHEDULE SHEET S003.
19. INDICATES A HOLDOWN MARK, SEE SCHEDULE SHEET S003.
H#
Structural Engineering
Stonecap, Inc.
1809 S Street, Ste. 101-277
Sacramento, CA 95811
© 2024 Stonecap, Inc.
SHELTER II
AT EAST BEAMER
1901 EAST BEAMER
WOODLAND, CA
95776
JOB NO.
DRAWN
DATE
SCALE
FILENAME
KEYPLAN
REVISIONS
9/26/2024 5:18:49
PM
ES
23035
S101
FOUNDATION
PLAN
S101 1/8" = 1'
-0"
1 FOUNDATION PLAN
PROGRESS SET NOT FOR CONSTRUCTION
A
5 H1
S602
1 S602
1 2
S601
___________
H1
B
C
E
F
G
H
K
L
1 2 3 4 6 7 8 9 10 11 12
D
J
RT-1
RT-1
RT-1
RT-1 RT-1 RT-1 RT-1 RT-1
RT-1
RT-1
RT-1
RT-1
RT-1
RT-1
RT-1
RT-1
6x12 6x12
6x12
6x12
6x12
6x12
6x12
6x12
H1
H1
H1
H1 H1
H1
H1
H1
H1
H1
H1
H1
H1 H1 H1
H1
H1
H1
H1 H1 H1 H1
H1 H1
H1 H1
H1
H1
H1
H1
H1 H1
1 S601
___________
7 S601
___________
3 S602
___________
7 S601
___________
7 S601
___________
1 S601
___________
1 S601
___________
7 S601
___________
2 S601
___________ 2
S601
___________ 2
S601
___________
2 S601
___________
2 S601
___________
2 S601
___________
2 S601
___________ 2
S601
___________
RT-1 RT-1
3 S602
___________
7 S601
___________
6x12 6x12 6x12 6x12 6x12 6x12
SW1
10'-0"
SW1
10'-0"
SW1
17'-6"
SW1
19'-7"
SW1
22'-3"
SW1
44'-7"
SW1
17'-0"
SW1
19'-7"
SW1
35'-11"
SW1
35'-5"
SW1
20'-0"
S
W1
21'-8" 20'-2"
SW1
23'-2"
SW1
S
W1
14'-0"
H2
H2
9'-7"
SW3
H1
H1
31'-1"
SW1
31'-1"
SW1
H1
H1
H1
H1
9'-11"
SW4
H1
H1
S
W2
17'-9"
4 S601
___________
H1
H1
H1
H1
S
W1
15'-9"
S
W1
7'-3"
S
W1
12'-6"
S
W1 (FTA
O)
20'-0"
S
W1 (FTA
O)
15'-0"
H1
H1
ST-A ST-A
H1
SW1
11'-3"
H1
ST-1&2
5.5K
WH-1&2
750 LBS
KH-1
1100 LBS
MAU-1
500 LBS
ERV-1
1000 LBS
S600
9 TYP
(12) PLACES
S600
9 TYP
(8) PLACES
S600
9 TYP
(8) PLACES
S600
TYP 9
(4) PLACES
FB-1
FB-1
2 S601
___________
8'-7"
SW2
H2
H2
7 S601
___________
5 S601
___________
6x12
FRAMING PLAN NOTES:
1. FOR GENERAL STRUCTURAL NOTES SEE S001
2. FOR HEADERS CALLED OUT ON PLAN PROVIDE 2X TRIMMER @ 7¼ OR LESS HEADER; (2) 2X TRIMMER @ 9½ OR GREATER
3. ALL LOAD BEARING DEMISING WALLS SEE LOAD BEARING WALL SCHEDULE ON S003.
4. EXTERIOR WALLS WITHOUT SHEARWALL SHEATHING SHALL HAVE SUBSTRATE SHEATHING PER ARCHITECTURAL DRAWINGS.
5. FOR TYPICAL STUD WALL FRAMING SEE 8/S600.
6. FOR STAIR STRINGER SIZE SEE 4 & 5/S603.
7. SEE DETAIL 10/S600 FOR ROUGH OPENINGS AROUND PTAC UNITS
8. PROVIDE MULTIPLE STUDS UNDER MULTIPLE JOISTS AND GIRDER TRUSSES (GT)
9. COLUMNS ARE CALLED OUT AT THE BASE LEVEL OF COLUMN AND CONTINUOUSLY STACK TO THE ROOF OR UNTIL IT IS NO LONGER SHOWN ON PLANS.
10. "C" = INDICATES CAMBER BETWEEN SUPPORTS ONLY @ GLUED, LAMINATED BEAMS. (i.e. NO CAMBER @ CANTILEVERS)
11. PROVIDE BOUNDARY NAILING ALONG ALL STRUT MEMBERS, INTERIOR SHEAR WALLS, AND INTERIOR LATERAL FRAMES U.N.O.
12. CONTRACTOR SHALL COORDINATE ALL MECH'L. UNIT LOCATIONS, SIZES, OPENINGS, ETC. WITH MECH'L. DRAWINGS.
13. SEE ARCH. FOR ALL DIMENSIONS & CONDITIONS NOT SHOWN.
14. TYPICAL FLOOR SHEATHING SHALL BE 23/32" APA RATED SHEATHING, STURD-I-FLOOR, OR SINGLE FLOOR (EXPOSURE 1) (40/20) W/ 10d COMMON NAILS @ 6"O.C. BOUNDARIES & CONT.
PANEL EDGES, 6"O.C. OTHER PANEL EDGES, AND 12"O.C. FIELD NAILING. (UN-BLOCKED, T&G @
UNSUPPORTED PANEL EDGES)
15. TYPICAL ROOF SHEATHING SHALL BE 15/32" APA RATED SHEATHING, STURD-I-FLOOR, OR SINGLE FLOOR (EXPOSURE 1) (32/16) W/ 10d COMMON NAILS @ 6"O.C. BOUNDARIES & CONT.
PANEL EDGES, 6"O.C. OTHER PANEL EDGES, AND 12"O.C. FIELD NAILING. (UN-BLOCKED, T&G @
UNSUPPORTED PANEL EDGES)
16. UNLESS SPECIFICALLY NOTED ON THE PLANS, FRAMING SHALL NOT BE CUT OR RELOCATED WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. CONTRACTOR SHALL OBTAIN APPROVAL OF JOIST MFR. SHOP DRAWINGS FROM BOTH MECHANICAL AND STRUCTURAL ENGINEERS PRIOR TO ERECTION OF JOIST FRAMING.
17. ALL MULTIPLE JOISTS SHALL HAVE EACH JOIST NAILED TO THE ADJACENT ONE WITH 16d @ 16"O.C. STAGGERED.
18. ALL MULTIPLE STUDS SHALL HAVE EACH STUD NAILED TO THE ADJACENT ONE WITH SOLE PLATE NAILING PER SHEAR WALL SCHEDULE, 10d @9"O.C. STAGGERED MINIMUM.
19. FOR HEADER SIZES NOT NOTED, REFER TO TYPICAL DETAIL SCHEDULE.
20. FOR LOW SPOTS CREATED BY THE ROOF PITCH SHALL BE PROVIDED WITH CRICKETS AS REQUIRED TO SLOPE AS REQUIRED.
21. ALL ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) SHALL MEET THE MINIMUM SPECIFICATIONS IN THE AISC CODE OF STANDARD PRACTICE CHAPTER 10 UNLESS NOTED OTHERWISE ON THE ARCHITECTURAL DRAWINGS.
22. SW# INDICATES SHEAR WALL MARK, SEE SCHEDULE SHEET S003.
23. (FTAO) INDICATES FORCE TRANSFER AROUND OPENING, SEE DETAIL 10/S602.
24. INDICATES A HOLDOWN MARK, SEE SCHEDULE SHEET S003 AND ATS SHEETS.
HOLDDOWNS SHOWN ARE AT THE LEVEL BELOW THE FRAMING PLAN.
25. SEE DETAIL 3/S500 FOR 'ATS ABV' CONNECTION TO STEEL COLUMN/BEAM.
26. INDICATES DRAG STRUT, SEE DETAIL 7/S600.
27. INDICATES COLLECTOR, SEE DETAIL 7/S600.
28. INDICATES STRUT/COLLECTOR TYPE PER DETAIL 7/S600.
29. MOMENT FRAME CONNECTION, SEE DETAIL 12/S500.
30. SIMPSON 'HU' HANGER U.N.O.
H#
ST-X
Structural Engineering
Stonecap, Inc.
1809 S Street, Ste. 101-277
Sacramento, CA 95811
© 2024 Stonecap, Inc.
SHELTER II
AT EAST BEAMER
1901 EAST BEAMER
WOODLAND, CA
95776
JOB NO.
DRAWN
DATE
SCALE
FILENAME
KEYPLAN
REVISIONS
9/26/2024 5:18:50
PM
Author
23035
S102
ROOF FRAMING
PLAN
S102 1/8" = 1'-0"
1 ROOF FRAMING PLAN
PROGRESS SET
NOT FOR
CONSTRUCTION
STUDS PER PLAN
SHEAR WALL PER PLAN
PTDF SILL PL W/ A.B. & PL
WASHER PER PLAN
PER PLAN
FTG WIDTH
FDN REINF. PER PLAN
E.N.
BASE & VAPOR BARRIER
PER PLAN OR
GEOTECHNICAL REPORT
STUDS PER PLAN
SHEAR WALL PER PLAN
PTDF SILL PL W/ A.B. & PL
WASHER PER PLAN
#3 DOWELS @24"OC
C
V
R
3"
FTG WIDTH PER PLAN
FDN REINF. PER PLAN
36" MIN. LAP
E.N.
6" MIN. 18" MIN.
BLW BLD
G PA
D
MIN. FTG DEPTH PER PLAN
BASE & VAPOR
BARRIER PER PLAN OR
GEOTECHNICAL
REPORT
1'-0"
PER ARCH
#4 CONT. AT EDGE
CONC SLAB PER PLAN
PIPE THRU FTG/FTG WALL
SLEEVES 2" LARGER THAN
O.D. OF PIPES
TYP.
MIN.
3"
SEE NOTE
1'-6"
NOTE: FOR PIPES 3'-0" OR LESS BELOW FTG,
PROVIDE SLEEVE AND CONC. AS SHOWN. FOR
GREATER THAN 3'-0", COMPACT BACKFILL OVER
PIPE TO 90% AS APPROVED BY GEOTECHNICAL
ENGINEER. USE STEPPED FTG BELOW PIPE.
NOTE: CONTRACTOR SHALL BE RESPONSIBLE FOR
SHORING, SHEATHING, OR OTHERWISE
MAINTAINING THE SIDES OF THE EXCAVATION
FROM CAVE-IN UNTIL ALL BACKFILL IS COMPLETED
PER SPECIFICATIONS.
COMPACTED FILL 90% DENSITY AS
APPROVED BY GEOTECHNICAL ENGINEER
BOTTOM OF TRENCH EXCAVATION SHALL
NOT EXTEND BELOW THIS LINE
1'-6" MIN. 9" MIN.
10'-0" MIN.
BACKFILL PER SPEC FTG
2 1
1 2
STUDS PER PLAN
SHEAR WALL PER PLAN
PTDF SILL PL W/ A.B. & PL
WASHER PER PLAN
PER PLAN
FTG WIDTH
FDN REINF. PER PLAN
E.N.
#3 CONT.
#3 @16"OC
PER ARCH
BASE & VAPOR BARRIER
PER PLAN OR
GEOTECHNICAL REPORT
1/4 OF SLAB THICKNESS
DEEP TOOL JOINT W/ 1/4"
MAX EDGE RADIUS
CONC. SLAB PER PLAN
SAWCUT WITHIN 12 HR OF
PLACING CONCRETE
(ALTERNATIVE)
STD HOOK
OPN'G REINF.
STD
HOOK
SPLICE
BAR LAP
(1) #5 TYP
OPNG REINF.
INTERSECTION
REINFORCING EACH FACE
INTERSECTION CORNER
REINFORCING EACH FACE
CORNER
VERT
REINF ON
WALL
OPN'G REINF.
180° HOOK
OPN'G REINF.
OPN'G REINF.
180°
HOOK
4"
REINFORCING
EACH FACE
SINGLE CURTAIN TYPICAL LINTEL
TOP OF WALL
JAMB & WALL
ENDS
NOTES:
1. GROUT ALL CELLS OR CAVITIES SOLID
2. AT CMU WALLS USE OPEN END BLOCK AT VERTICAL REINFORCING BARS
3. REFER TO TYPICAL MASONRY WALL REINFORCING SCHEDULE
4. AT DOUBLE CURTAIN REINFORCING STAGGER VERTICAL AND HORIZONTAL BARS. PLACE VERTICAL REBAR AS CLOSE TO MASONRY SURFACE AS THE MINIMUM CLEARANCES WILL PERMIT.
CORNER INTERSECTION ANGLE
END
DOUBLE CURTAIN
LENGTH OF BENDS
SHALL BE LARGER
OR 18" PER
CORNER INTERSECTION ANGLE
END
SINGLE CURTAIN
SIMPSON 0.157"Ø
'PDPA-250' SHOT DRIVEN
PINS @32"OC TYP.
2X P.T.D.F. SILL PL
CONC. SLAB PLAN
STUDS PER PLAN @
16"OC NON-BEARING
WALL
E.N. - FULL HT MIN. THK
HOLDDOWN PER PLAN
LAG SCREW OR SDS
CONNECTION TO POST
TO PROVIDE DUCTILE
YIELDING
END POST PER
PLAN
TOP OF FOOTING,
GRADE BEAM, OR
COLD JOINT
END OF FTG
WHERE OCCURS
de MIN. I1
CVR
3"
F MIN F MIN
PL AND WSHR PER
SCHEDULE
C
V
R
3"
TOP OF CONC SLAB,
CURB, OR STEM
THICKEN FTG AS
REQUIRED FOR MIN.
A.B. EMB.
A
A
PROVIDE (6) #3 TIES @
6"OC MIN FOR ALL ATS
HOLD DOWNS AND
'PAB8' TO 'PAB10' de MIN
COLD JOINT
WHERE OCCURS
2F MIN
SECTION A-A
SIMPSON
'PAB'
DIAMETER
(IN.)
de MIN.
(IN.)
F MIN.
(IN.)
I1 MIN.
(IN.)
PL WSHR SIZE
(IN.)
PAB5 5/8" 7" 10½" 1¼" 3/8"X1½"X1½"
PAB6 3/4" 9" 13½" 1 3/8" 3/8"X1½"X1½"
PAB7 7/8" 11" 16½" 1½" 3/8"X1½"X1½"
PAB7H 7/8" 16" 24" 1½" 3/8"X1½"X1½"
PAB8 1" 12" 18" 1 5/8" 3/8"X1½"X1½"
PAB8H 1" 19" 28½" 1 5/8" 3/8"X1½"X1½"
PAB9 1 1/8" 14" 21" 1¾" 3/8"X1½"X1½"
PAB10 1 1/4" 16" 24" 2½" 3/8"X1½"X1½"
ANCHOR BOLT SCHEDULE
DESIGN LOADS ARE CALCULATED USING A
FULL SHEAR CONE. COVERAGE ON EACH SIDE
OF THE BOLT SHALL BE A MINIMUM OF F OR
REDUCTIONS MUST BE TAKEN.
NOTES:
1. ANCHOR EMBEDMENT LENGTH IS BASED ON A SINGLE POUR CONCRETE FOUNDATION WITHIN THE FOOTING DIMENSIONS de AND F. DOUBLE POUR FOUNDATIONS SYSTEMS, MASONRY WALLS, AND MASONRY FOOTINGS MUST BE EVALUATED BY THE DESIGNER.
2. ANCHOR BOLT MUST BE ASTM A307 OR A36 STEEL.
3. ANCHOR HEAD REQUIRED (2) HEX NUTS W/ A 2¼X2¼X3/8" PLATE, USE OF SIMPSON STRONGTIE BEARING PLATE BP1 MAY BE USED AS SUBSTITUTE PLATE FOR 1"⌀ BOLTS AND BP¾ MAY BE USED AS SUBSTITUTE PLATE FOR ¾"⌀ BOLTS.
4. DESIGN VALUES ARE BASED ON ACI318 WHERE CRACKED CONCRETE IS ASSUMED AND ADDITIONALLY FOR SEISMIC LOADS DUCTILITY REQUIREMENTS ARE CONSIDERED.
5. FOR HOLDDOWNS, PER ASTM TEST STANDARDS, ANCHOR BOLT NUT SHOULD BE FINGER-TIGHT PLS 1/3 TO 1/2 TURN WITH A HAND WRENCH, WITH CONSIDERATION GIVEN TO POSSIBLE FUTURE WOOD SHRINKAGE. CARE SHOULD BE TAKEN TO NOT OVER-TORQUE THE NUT. IMPACT WRENCHES SHOULD NOT BE USED.
6. TENSION VALUES ARE VALID FOR HOLDDOWNS FLUSH OR RAISED OFF SILL PLATE.
7. HDU14 ALLOWABLE LOADS ARE BASED ON 6X6 POST. ALL OTHER LOADS BASED ON 4X MIN POST.
8. REQUIRES HEAVEY HEX ANCHOR NUT TO ACHIEVE LOAD VALUES.
SIMPSON
'PAB'
DIAMETER
(IN.)
de MIN.
(IN.)
F MIN.
(IN.)
I1 MIN.
(IN.)
PL WSHR SIZE
(IN.)
PAB4 1/2" 15" 12" 1¼" 3/8"X1½"X1½"
PAB8H 1" 15" 15" 1 5/8" 3/8"X1½"X1½"
ATS ANCHOR BOLT SCHEDULE
PTDF SILL PL W/ A.B. & PL
WASHER PER PLAN
#3 DOWELS @24"OC
C
V
R
3"
FTG WIDTH PER PLAN
FDN REINF. PER PLAN
36" MIN. LAP
E.N.
PER ARCH
8" MIN
#3 CONT.
#3 @16"OC
C
V
R BLW PIPE
1'-0"
MIN. EMB.
9"
18" MIN.
10" THK
UTILITY LINE
PER CIVIL
3/C3.1
PER CIVIL
3/C3.1
PER CIVIL
1 1
ADJACENT (E)
BUILDING FOOTING
NOTE:
CONTRACTOR TO VERIFY IN FIELD
THAT (E) FTG FROM ADJACENT
BUILDING DOES NOT INFLUENCE
(N) FOOTING
STUDS PER PLAN
SHEAR WALL PER PLAN
PTDF SILL PL W/ A.B. & PL
WASHER PER PLAN
#3 DOWELS @24"OC
C
V
R
3"
FDN REINF. PER PLAN
36" MIN. LAP
BLW BLD
G PA
D
MIN. FTG DEPTH PER PLAN
9" EMB. MIN.
PROPERTY LINE
PER ARCH
BASE & VAPOR
BARRIER PER PLAN OR
GEOTECHNICAL
REPORT
6" MIN.
PER PLAN
FTG WIDTH FDN REINF.
PER PLAN
2" CVR
STL. COL. PER PLAN
1 1/2" MIN. DRYPACK
OPTIONAL COLD JOINT
SLAB PER PLAN
A.B. SIZE, QTY, &
LOCATION PER PLAN
C
V
R
3"
TIES WHERE
OCCURS
FTG THICKNESS PER PLAN
℄
1/4"
'D' PER PLAN
MATCH BM DEPTH
#4 TYP.
#4 @12"OC
TYP..
CONC. FTG OR GRADE BM &
REINF. PER PLAN. REINF.
SHOWN FOR REFERENCE ONLY
PER PLAN
FTG DEPTH
1.75 X 'S' MIN.
2'-0" M
A
X
'S'
TYPICAL SPLICES
WIRE TIES
SEE SCHED. & NOTES
40d IN MASONRY
'B' OR 'C' IN CONC.
STAGGERED SPLICES
'B' 'B'
BAR SIZE 3000 PSI 4000 PSI
#4 24" 24"
#5 24" 24"
#6 25" 24"
#7 34" 30"
#8 45" 39"
#9 57" 49"
#10 72" 63"
#11 89" 77"
SCHED. OF MIN. SPLICE LENGTH
'B' FOR ACI CLASS B LAP SPLICE NOTES:
1. FOR TOP BARS USE SPLICE LENGTH SHOWN ABOVE X 1.3.
2. d=NORMAL DIAMETER OF SPLICE BAR.
3. SPLICES OF REPETITIVE REINF. IN CONC. SHALL BE
STAGGERED PER ACI CLASS B SPLICES AS SHOWN ABOVE.
4. FOR NON-REPETITIVE REINF. IN CONC. OR WHERE SPLICES
CANNOT BE STAGGERED, USE ACI CLASS C SPLICES.
5. SPLICES SHALL BE MADE AWAY FROM POINTS OF MAX.
STRESS OR AT LOCATIONS SHOWN PER PLAN
6. NO LAP SHALL BE LESS THAN 2 FEET.
Structural Engineering
Stonecap, Inc.
1809 S Street, Ste. 101-277
Sacramento, CA 95811
© 2024 Stonecap, Inc.
SHELTER II
AT EAST BEAMER
1901 EAST BEAMER
WOODLAND, CA
95776
JOB NO.
DRAWN
DATE
SCALE
FILENAME
KEYPLAN
REVISIONS
9/26/2024 5:18:51
PM
Author
23035
S300
FOUNDATION
DETAILS
S300 1" = 1'-0"
11 INTERIOR WALL FDN
S300 1" = 1'-0"
12 EXTERIOR WALL FDN W/ CURB
S300 1" = 1'-0"
9 SOG STEP
S300 1" = 1'-0"
4 PIPES IN FOOTING
S300 1" = 1'-0"
1 TRENCH DETAIL
S300 1" = 1'-0"
10 INTERIOR WALL W/ CURB
S300 1" = 1'-0"
8 SOG CONTROL JOINT
S300 1" = 1'-0"
2 CMU REINF. INTERSECTIONS - TYP
S300 1" = 1'-0"
3 REINFORCEMENT INTERSECTIONS - TYP
S300 1" = 1'-0"
5 NON-LOADBEARING/SHEARWALL
S300 1" = 1'-0"
6 HOLD DOWN FDN DETAIL - TYP
S300 1" = 1'-0"
13 DEEPENED FDN W/ CURB
S300 1" = 1'-0"
14 EXTERIOR WALL FDN @ PL
S300 1" = 1'-0"
15 COLUMN FOOTING
S300 1" = 1'-0"
16 STEPPED FOOTING (OPTION B)
S300 1" = 1'-0"
7 REINFORCEMENT INTERSECTIONS - TYP
PROGRESS SET
NOT FOR
CONSTRUCTION
BN @ PERIMETER OF
DIAPHRAGM
BLKG. & BN @ ALL
UNSUPPORTED
EDGES WHERE
BLOCKED DIAPH. ARE
SPECIFIED UNO, EN
MAY BE USED ONLY IF
PANEL JOINTS ARE
STAGGERED
PROVIDE (2) ROWS OF
BN @ ALL 'STRUTS',
INTERIOR SHEAR
WALLS, AND INTERIOR
LATERAL FRAMES
FULL LENGTH OF
DIAPHRAGM TYP.
STRUT WHERE
INDICATED ON PLANS
LEDGER PER PLAN
EN @ ALL STAGGERED
JOINTS
MIN. PLYWD
AREA IS 8 SQ FT
FN @ INTERIOR
SUPPORTS
JOISTS
PER PLAN
LEGEND
EN = EDGE NAILING
BN = BOUNDARY NAILING
FN = FIELD NAILING
MIN. PLYWD WIDTH IS 24"
STAGGER JOINTS
16" MIN.
60% MAX STUD WIDTH BORE
2"Ø @2X4 STUDS &
3 1/4"Ø @2X6 STUDS
.
40% MAX NOTCH
1 3/8" MAX @2X4 STUDS
2 1/8" MAX @2X6 STUDS
.
.
5/8" MIN. EDGE
TYP ALL STUDS
WIDTH OF STUD MAX
TYP ALL STUDS
NON-BEARING STUDS
40% MAX STUD WIDTH BORE
1 3/8"Ø MAX @2X4 STUDS
2 1/4"Ø MAX @2X6 STUDS
DOUBLE STUDS
.
.
40% MAX NOTCH
1 3/8"Ø MAX @2X4 STUDS
2 1/8"Ø MAX @2X6 STUDS
.
WIDTH OF STUD MAX
TYP ALL STUDS
EXTERIOR & BEARING STUDS
25% MAX NOTCH
7/8"Ø MAX @2X4 STUDS
1 3/8"Ø MAX @2X6 STUDS
COLUMN
.
30% MAX COLUMN
WIDTH BORE @ CENTER
OF COLUMN
NOTES:
1. BORING OF MORE THAN (2)
SUCCESSIVE DOUBLE STUDS IS
NOT PERMITTED.
2. NOTCH AND BORING IS NOT TO
OCCUR IN THE SAME STUD
SECTION
(4) 16d EA SIDE OF
BEAM
BEAM PER PLAN
2X F.H. STUD W/ 16d @
8"OC STAGGERED EA
SIDE OF BEAM
COLUMN BELOW
BEAM PER PLAN
A
A
SECTION A-A
'A35' EA SIDE OF BEAM
BEAM PER PLAN
DOUBLE TOP PL
MIN (2) 16d SINKER TN
EA SIDE
COLUMN OR MULTISTUD PER PLAN
(4) 16d SINKER TN EA
SIDE
SILL PL
'A35' EA SIDE OF BEAM SIMPSON 'MST48' UNO
DOUBLE TOP PL
(1) 16d SINKER FOR EA
2" OF BM DEPTH ON EA
SIDE OF BEAM
'A35' EA SIDE
BEAM PER PLAN
'MST48' UNO (ALT.
LOCATION @ SIDE OF
PL
DOUBLE TOP PL
(1) 16d SINKER FOR EA
2" OF BM DEPTH ON EA
SIDE OF BEAM
'A35' EA SIDE
BEAM PER PLAN
12" MAX FROM SILL PL END
5" MIN
9" TYP.
HEADER PER PLAN OR
PER SCHEDULE
'A34' EA SIDE T&B FOR
OPENINGS > 8'-0"
(2) 16d MIN EA END
ADDITIONAL (2) 16d EA
END FOR EA ADD'L 2"
HDR DEPTH
10d @12"OC EA SIDE
STAGGERED
WINDOW OPENING
DOOR OPENING
SIMILAR
TRIMMERS BLW HDR
PER SCHEDULE
STUDS PER PLAN
JACK STUDS SAME
SIZE AS STUDS. # PER
SCHEDULE
'A34' T&B @
OPENINGS > 8'-0"
END OF WALL
HOLDDOWN POST
MAY BE USED IN LIEU
OF JACK STUD WHERE
OCCURS
P.T.D.F. SILL PL PER
PLAN
HOLDDOWN PER PLAN
ADDITIONAL STUD OR
WIDER STUD PER
HOLDDOWN SCHEDULE
FIRE BLOCK STUD WALLS &
PARTITION (HORIZONTALLY
@10' INTERVALS &
VERTICALLY @ CEILING &
FLOOR LEVELS), ENCLOSED
& CONCEALED SPACES, & AT
OPENINGS AROUND VENTS,
PIPES, DUCTS, CHIMNEY
CHASES, AT STAIR
STRINGERS, & SIMILAR
PLACES AT CEILING & FLOOR
LEVELS.
DOUBLE 2X TOP PL
BLKG
TOP PL WALL PER PLAN
SHEAR WALL PER PLAN
SHEAR WALL PER PLAN
SIMPSON 'CMST14'
STRAP LENGTH PER
PLAN
LENGTH PER PLAN
10d@3-1/2"OC TO BLKG
BLKG TYP.
(37) 16d TO PL
LENGTH PER PLAN
10d@3-1/2"OC TO BLKG
SIMPSON 'CMST14' STRAP
LENGTH PER PLAN
E.N.
SHEAR WALL PER PLAN
SHEAR WALL PER PLAN
DISCONTINUOUS TRUSS
PER PLAN
EQ EQ
SIMPSON 'MST48'
NOTE:
TRUSSES USED AS A STRUT OR COLLECTOR SHALL BE DESIGNED FOR 240 PLF
LATERAL FORCE ALONG TOP CHORD OF TRUSS
BLKG
4'-0" W/ 16d TO BLKG 4'-0" W/ 16d TO BLKG
SIMPSON 'CMST14' STRAP
E.N.
SHEAR WALL PER PLAN
BLKG
TOP PL WALL PER PLAN
EQ EQ
SIMPSON 'MSTC48' STRAP
ST-A ST-B
ST-C ST-D
ST-E ST-F
'CMST12' 4X BLKG
W/ 10d@3"OC TO BLKG
12'-0" MIN OR END OF WALL
W/ (42) 16d TO TOP PL
38" MIN.
DBL TOP PL
E.N.
'CMST12'
A-A
A
A
TRUSS OR BEAM PER PLAN
BEAM OR TRUSS
BEAM WHERE OCCURS
B.N. TO FULL LENGTH
OF BLKG AND HEADER
TYP. HEADER PER PLAN.
3X BLKG BELOW
STRAPS TYP.
WINDOW OPENING
DOOR OPENING
SIMILAR
STUDS PER PLAN
E.N. REQ. F.H.@KING
STUDS
PLYWOOD SHEARWALL
CONTINUOUS VERTICAL
EDGE MEMBER PROVIDE
STRAP IF ANY
DISCONTINUITY
NOTES:
1. B.N. AROUND OPENING TYP. SEE
SHEARWALL SCHEDULE
2. IF SHTG IS ON OPPOSITE SIDE OF
STRAPS, ADD E.N. ALL BLKG.
1/8" MIN. THK END
PLATE
P.P.
FABRIC SHADE PER
ARCH.
ATTACHMENT PER
MANUF.
COLUMN PER PLAN
Structural Engineering
Stonecap, Inc.
1809 S Street, Ste. 101-277
Sacramento, CA 95811
© 2024 Stonecap, Inc.
SHELTER II
AT EAST BEAMER
1901 EAST BEAMER
WOODLAND, CA
95776
JOB NO.
DRAWN
DATE
SCALE
FILENAME
KEYPLAN
REVISIONS
9/26/2024 5:18:52
PM
Author
23035
S600
WOOD TYPICAL
DETAILS
S600 1" = 1'-0"
1 SHEATHING - TYP
S600 1" = 1'-0"
2 STUD NOTCHING - TYP
S600 1" = 1'-0"
4 MISC1/07A - TYP
S600 1" = 1'-0"
5 BEAM AT WALL - TYP
S600 1" = 1'-0"
6 POCKET BEAM TO WALL - TYP
S600 1" = 1'-0"
8 TYPICAL WALL FRAMING
S600 1" = 1'-0"
7 COLLECTOR/STRUT DETAIL
S600 1/2" = 1'-0"
3 SHEARWALL W/ OPENING
S600 1" = 1'-0"
9 FABRIC SHADE CONNECTION
PROGRESS SET
NOT FOR
CONSTRUCTION
STUDS WALL ABOVE PER
PLAN WHERE OCCURS
SHEAR WALL PER PLAN
E.N.
E.N.
SHEAR WALL PER PLAN
TRUSS PER PLAN
SHTG PER PLAN
2X BLKG @48"OC IN 'U'
HNGR
2X SOLE PL W/
FASTENERS TO RIM
JOIST PER SW SCHED.
2X BLKG W/ 'A35' TO TOP
PL 24"OC MAX. (IAPMO ES
ER-112)
B.N
TRUSS PER PLAN
STUDS PER PLAN
BALLOON FRAMED
PARAPET
2X BLKG
E.N.
E.N.
SHEAR WALL PER PLAN
JOISTS PER PLAN
SHTG PER PLAN
2X BLKG @24"OC IN 'JB'
HNGR & ROOF E.N.
(ICC-ES ESR-2553)
3/8" CDX PLYWD
BACKING W/ 8d @6"
E.N. & 12" F.N. WHERE
OCCURS
B.N.
2X BLKG
2X8 CONT. LEDGER W/
(2) 16d EA STUD W/
CMST14 STRAP EA
SPLICE
ADD (3) 16d EA BLK
4'-0" MAX
E.N.
SIMPSON 'H2A' @
24"OC (ICC-ES
ESR-2613)
BN
SHTG PER PLAN
TRUSS PER PLAN
GIRDER TRUSS PER PLAN
E.N.
SHEAR WALL PER PLAN
TRUSS PER PLAN W/
PARAPET
SHTG PER PLAN
2X BLKG W/ 'A35' @24"OC TO
TOP PLATE
B.N.
PARAPET FRAMING
DESIGN FOR 50PLF AT TOP
PL BY TRUSS MANUF.
2X BLKG
E.N.
3/8" CDX PLYWD
BACKING W/ 8d @6"
E.N. & 12" F.N. WHERE
OCCURS
E.N.
(2) SIMSPONS 'SDWS' 0.22X5
EA STUD TO PL
BEAM WHERE OCCURS PER
PLAN
E.N.
50 PLF
NOTE:
TRUSS MANUFACTURER TO DESIGN
PARAPETS FOR HORIZONTAL WIND
PRESSURE OF 40 PSF IN BOTH
DIRECTIONS.
2X BLKG w/ 'A35' EA BLK @
24"OC MAX
BN
TRUSS PER PLAN BOTH
SIDES WHERE OCCURS
SHTG PER PLAN
TRUSS PER PLAN
E.N.
SHEAR WALL PER PLAN
E.N.
SHEAR WALL PER PLAN
TRUSS PER PLAN
SHTG PER PLAN
B.N
TRUSS PER
PLAN
2X BLKG @48"OC IN 'U'
HNGR
LOAD BEARING NONSHEARWALL PER PLAN
TRUSS PER PLAN
SHTG PER PLAN
F.N
TRUSS PER
PLAN
2X BLKG @48"OC IN 'U'
HNGR
2X SOLE PL W/
FASTENERS TO RIM
JOIST PER SW SCHED.
B.N
E.N.
SHEAR WALL PER PLAN TRUSS PER PLAN
1.5" TIMBERSTRAND RIM
JOIST W/ 'A35' TO TOP PL
24"OC MAX. (IAPMO ES
ER-112)
SIMPSON 'LSTA18' @
48"OC TO JOIST
NOTE:
TRUSS MANUFACTURER TO DESIGN
PARAPETS FOR HORIZONTAL WIND
PRESSURE OF 40 PSF IN BOTH
DIRECTIONS.
E.N.
SHEAR WALL PER PLAN
TRUSS PER PLAN W/
PARAPET
SHTG PER PLAN
2X BLKG W/ 'A35' @24"OC TO
TOP PLATE
B.N.
PARAPET FRAMING
DESIGN FOR 50PLF AT TOP
PL BY TRUSS MANUF.
2X BLKG
E.N.
3/8" CDX PLYWD
BACKING W/ 8d @6"
E.N. & 12" F.N. WHERE
OCCURS
E.N.
(2) SIMSPONS 'SDWS' 0.22X5
EA STUD TO PL
E.N.
50 PLF
E.N.
Structural Engineering
Stonecap, Inc.
1809 S Street, Ste. 101-277
Sacramento, CA 95811
© 2024 Stonecap, Inc.
SHELTER II
AT EAST BEAMER
1901 EAST BEAMER
WOODLAND, CA
95776
JOB NO.
DRAWN
DATE
SCALE
FILENAME
KEYPLAN
REVISIONS
9/26/2024 5:18:52
PM
ES
23035
S601
WOOD DETAILS
S601 1" = 1'-0"
3 INTERIOR WALL
S601 1" = 1'-0"
7 PARAPET DETAIL
S601 1" = 1'-0"
9 ROOF GIRDER TRUSS
S601 1" = 1'-0"
1 PARAPET TRUSS PERP TO SHEARWALL
S601 1" = 1'-0"
2 ROOF TRUSS PERPENDICULAR TO SHEAR WALL
S601 1" = 1'-0"
4 ROOF JOISTS // TO SHEARWALL
S601 1" = 1'-0"
5 LOW AND HIGH ROOF TRANSITION
PROGRESS SET
NOT FOR
CONSTRUCTION
FRAMING PER PLAN
DOUBLE JOIST OR TRUSS
BLOCKING IN SIMPSON 'BA'
HNGR. MATCH DEPTH OF
FRAMING.
SEE PLAN FOR SHEATHING
2X6 BLKG MIN. IN
SIMPSON 'JB' HNGR
TYP
SIMPSON 'LSTA18'
TYP
OPEN
NOTE:
1. OPENING TO BE 4'-0" SQUARE MAXIMUM.
2. SPACING OF OPENINGS NO CLOSER THAN 6'-0" CC.
DBL JOISTS OR TRUSSES
FRAMING PER PLAN
HEADER PER PLAN
SEE PLAN FOR SHEATHING
3X BLKG BELOW
STRAPS
SIMPSON 'CS16' PLACE
OVER PLYWOOD W/
10d@2"OC
WINDOW
ROUGH OPENING
NOTE:
1. B.N. AROUND OPENING TYP. SEE SHEAR WALL SCHED.
2. IF SHEATHING IS ON OPPOSITE SIDE OF STRAPS, ADD
E.N. ALL BLKG.
R.O. WIDTH
16" MIN TYP
1/2 OF R.O. WIDTH CONTINUOUS VERTICAL EDGE
MEMBER PROVIDE STRAP IF
ANY DISCONTINUITY
B.N.
STUD WALL PER PLAN
4X12 BLKG W/ 'A34' T&B BOTH
SIDES TO STUD
TRUSS PER PLAN
2X8 LEDGER W/ (3)10d@
12"OC TO BLOCKING
SIMPSON 'LSTA15' FROM
BLKG & LEDGER TO BLKG
2X BLKG @48"OC IN
'JB' HNGR (ICC-ES
ESR-2553)
SHEAR WALL PER PLAN
FASCIA PER ARCH
W/ (3) 10d TO BLKG
SHEAR WALL PER PLAN
TRUSS PER PLAN
SHTG PER PLAN
2X BLKG @48"OC IN 'U'
HNGR
1.5" LSL RIM JOIST W/ 'A35'
TO TOP PL 24"OC MAX.
(IAPMO ES ER-112)
E.N.
B.N.
PER ARCH
VARIES
PER ARCH
1'-0" MAX OVRHNG
Structural Engineering
Stonecap, Inc.
1809 S Street, Ste. 101-277
Sacramento, CA 95811
© 2024 Stonecap, Inc.
SHELTER II
AT EAST BEAMER
1901 EAST BEAMER
WOODLAND, CA
95776
JOB NO.
DRAWN
DATE
SCALE
FILENAME
KEYPLAN
REVISIONS
9/26/2024 5:18:52
PM
Author
23035
S602
WOOD DETAILS
S602 1" = 1'-0"
1 DIAPHRAGM OPENING
S602 1" = 1'-0"
2 FORCE TRANSER AROUND OPENING
S602 1" = 1'-0"
3 LOW AND HIGH ROOF TRANSITION PROGRESS SET
NOT FOR
CONSTRUCTION
PROJECT NUMBER: CLIENT: PHASE: SHEET TITLE: SHEET: All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer. REVISIONS: 2222 NE OREGON ST. SUITE 101 PORTLAND, OR 97232 PHONE: 503.702.2575 WWW.SALAZARCH.COM DRAWN BY: CHECKED BY: DATE CREATED: Salazar Architect, Inc. # DATE DESCRIPTION 2321 SHELTER II AT EAST BEAMER 1901 EAST BEAMER STREET WOODLAND, CA 95776 APN:027-360-042 THURMOND CONSULTING 2122 NATOMAS CROSSING SUITE 200-288 SACRAMENTO, CA 95834 75% CONSTRUCTION DOCUMENTS 10/02/24 M-001 EDC EDC MECHANICAL TITLE SHEET TV TURNING VANES DRAWING NUMBER DETAIL NUMBER CEILING SUPPLY DIFFUSER/REGISTER CEILING RETURN GRILLE/REGISTER RETURN AIR DUCT RISER/DROP EXHAUST AIR DUCT RISER/DROP CEILING EXHAUST GRILLE/REGISTER WALL SUPPLY GRILLE/REGISTER WALL RETURN OR EXHAUST GRILLE/REGISTER SUPPLY AIR DUCT RISER/DROP R or D AL FS SLOPED DUCT (RISE OR DROP) FLEXIBLE DUCT SQUARE TO ROUND DUCT FIRE-SMOKE DAMPER ACOUSTICAL LINING (1" FIBERGLASS U.O.N.) VD VOLUME DAMPER TEMPERATURE SENSOR (MOUNT AT 48" AFF) TS T-STAT THERMOSTAT (MOUNT AT 48" AFF) DUCT CONTINUATION BDD BACK DRAFT DAMPER H HUMIDISTAT (MOUNT AT 48" AFF) SLOT DIFFUSER WITH AIR DUCT MECHANICAL SHEET NOTE RL REFRIGERANT LIQUID RS REFRIGERANT SUCTION CO2 SENSOR SYMBOL ABBR DESCRIPTION DRAWING NUMBER SECTION NUMBER UNIT NUMBER EQUIPMENT TYPE NECK SIZE AIR QUANTITY SYMBOL (4-WAY UON) CEILING OUTSIDE AIR GRILLE/REGISTER CEILING TRANSFER DIFFUSER/GRILLE OUTSIDE AIR DUCT RISER/DROP (D) HHWS HEATING HOT WATER SUPPLY HHWR HEATING HOT WATER RETURN HHWS HHWR CHWS CHILLED WATER SUPPLY CHWR CHILLED WATER RETURN CHWS CHWR BOTTOM CONNECTION - BRANCH LINE CIRCUIT SETTER TEE DOWN TEE UP TOP CONNECTION - BRANCH LINE PIPE DOWN PIPE UP PIPE ANCHOR AUTOMATIC AIR VENT EXPANSION LOOP CAPPED OR PLUGGED TEE EXPANSION JOINT PIPE GUIDE TEST TAP (PETE'S PLUG) MANUAL AIR VENT FLEXIBLE CONNECTOR UNION AAV MV PRESSURE GAGE THERMOMETER PUMP PRESSURE GAUGE WITH COCK STRAINER WITH BLOW OFF STRAINER 3-WAY CONTROL VALVE 2-WAY CONTROL VALVE MOTORIZED BUTTERFLY VALVE CHECK VALVE GATE VALVE DIRECTION OF FLOW DIRECTION OF SLOPE BUTTERFLY VALVE RELIEF VALVE, P&T RELIEF VALVE BALL VALVE P&TRV ∅ DIAMETER AC AIR CONDITIONING AFF ABOVE FINISHED FLOOR AMP AMPERE ARCH ARCHITECTURAL BDD BACKDRAFT DAMPERS BHP BRAKE HORSEPOWER BLDG BUILDING BOD BOTTOM OF DUCT BTU BRITISH THERMAL UNIT BTUH BRITISH THERMAL UNIT PER HOUR CFM CUBIC FEET PER MINUTE CL CENTER LINE CLG CEILING DBT DRY BULB TEMPERATURE DN DOWN DSD DUCT MOUNTED SMOKE DETECTOR (E) EXISTING EA EXHAUST AIR EAT ENTERING AIR TEMPERATURE EER ENERGY EFFICIENCY RATIO ELEC ELECTRICAL ESP EXTERNAL STATIC PRESSURE (IN WG) EWT ENTERING WATER TEMPERATURE F FAHRENHEIT FA FACE AREA FLA FULL LOAD AMPS FD FIRE DAMPER FPM FEET PER MINUTE FSD FIRE/SMOKE DAMPER FT FEET GA GAUGE GAL GALLONS GALV GALVENIZED GPM GALLONS PER MINUTE HD HEAD HP HORSEPOWER HVAC HEATING VENTILATING AND AC HZ HERTZ ID INSIDE DIAMETER IN. INCH IN. W.G. INCHES WATER GAGE (PRESSURE) KW KILOWATT LAT LEAVING AIR TEMPERATURE LBS POUNDS LF LINEAR FEET LWT LEAVING WATER TEMPERATURE MA MIXED AIR MAX MAXIMUM MBH THOUSAND BTU PER HOUR MECH MECHANICAL MIN MINIMUM (N) NEW N/A NOT APPLICABLE NC NORMALLY CLOSED NIC NOT IN CONTRACT NO NUMBER OR NORMALLY OPEN NTS NOT TO SCALE OAT OUTSIDE AIR TEMPERATURE OBD OPPOSED BLADE DAMPER OC ON CENTER OD OUTSIDE DIMENSION OH OVERHEAD OSA OUTSIDE AIR PD PRESSURE DROP PH PHASE PLBG PLUMBING POC POINT OF CONNECTION POD POINT OF DEMOLITION RA RETURN AIR REQ'D REQUIRED REV REVISION RPM REVOLUTIONS PER MINUTE SA SUPPLY AIR SAD SEE ARCHITECTURAL DRAWINGS SCD SEE CIVIL DRAWINGS SED SEE ELECTRICAL DRAWINGS SD SMOKE DAMPER SEER SEASONAL ENERGY EFFICIENCY RATIO SF SQUARE FEET SP STATIC PRESSURE SPD SEE PLUMBING DRAWINGS SQ.FT. SQUARE FEET SSD SEE STRUCTURAL DRAWINGS TA TRANSFER AIR TCP TEMPERATURE CONTROL PANEL TEMP TEMPERATURE TOD TOP OF DUCT TYP TYPICAL UC UNDERCUT UG UNDERGROUND UON UNLESS OTHERWISE NOTED VAV VARIABLE AIR VOLUME VEL VELOCITY VFD VARIABLE FREQUENCY DRIVE WG WATER GAGE WT WEIGHT NOTE: NOT ALL SYMBOLS APPLY 1. 2022 BUILDING STANDARD ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R. 2. 2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R. 3. 2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R. 4. 2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R. 5. 2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R. 6. 2022 CALIFORNIA ENERGY CODE, PART 6, TITLE 24 C.C.R. 7. 2022 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24, C.C.R. 8. 2022 CALIFORNIA "GREEN" BUILDING REQUIREMENTS, PART 11, TITLE 24 C.C.R 9. 2022 CALIFORNIA EXISTING BUILDING CODE, PART 10, TITLE 24 C.C.R 10. 2022 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24, C.C.R. 11. TITLE 19, C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS REFERENCE CODE SECTION FOR NFPA STANDARDS - CBC(SFM) 3504.1 TITLE 24 C.C.R. ACCESSIBILITY STANDARDS AMERICAN WITH DISABILITIES ACT (A.D.A., ADAAG) FEDERAL ACCESSIBILITY STANDARDS LOCAL MUNICIPAL BUILDING CODES SYMBOLS ABBREVIATIONS NOTE: NOT ALL ABBREVIATIONS APPLY 1. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS OF TITLE 24 OF THE CALIFORNIA CODE OF REGULATIONS (C.C.R.), 2022 CMC. 2. ALL SYSTEMS SHALL BE INSTALLED IN STRICT ACCORDANCE WITH ALL APPLICABLE CITY, COUNTY, FEDERAL AND STATE CODES AND ORDINANCES, AND SHALL MEET ALL REQUIREMENTS OF ALL AUTHORITIES HAVING JURISDICTION. 3. SYSTEM LAYOUTS AS INDICATED ON DRAWINGS ARE GENERALLY DIAGRAMMATIC BUT SHALL BE FOLLOWED AS CLOSELY AS ACTUAL CONSTRUCTION WILL PERMIT. 4. PRIOR TO SUBMISSION OF BID, REVIEW FULL SET OF NEW CONSTRUCTION DRAWINGS (INCLUDING ALL OTHER TRADES). INCLUDE ANY ADDITIONAL PIPE OR DUCT OFF-SETS THAT ARE NOT CURRENTLY SHOWN ON DRAWINGS BUT MAY BE REQUIRED TO CLEAR STRUCTURE, FINISHES OR WORK OF OTHER TRADES. NO EXTRA PAYMENT WILL BE ALLOWED FOR WORK RESULTING FROM LACK OF PROPER INITIAL APPRAISAL OF ENTIRE SCOPE OF WORK. SUBMIT REQUESTS FOR INFORMATIONS (RFIS) AS REQUIRED TO ANSWER ANY QUESTIONS THAT MAY ARISE DURING BIDDING PHASE. CLEARLY INDICATE SCOPE INCLUSION AND EXCLUSION IN BID. 5. FURNISH ALL LABOR, MATERIALS, TRANSPORTATION, AND PERFORM ALL REQUIRED OPERATIONS TO PROVIDE COMPLETE AND OPERABLE MECHANICAL SYSTEM, IN ACCORDANCE WITH THE FULL INTENT AND MEANING OF THE DRAWINGS AND SPECIFICATIONS AND PER STANDARD TRADE PRACTICES. 6. WORKMANSHIP SHALL BE FIRST CLASS THROUGHOUT AND PERFORMED ONLY BY COMPETENT AND EXPERIENCED WORKMEN IN A MANNER SATISFACTORY TO THE OWNER, ARCHITECT AND MECHANICAL ENGINEER. 7. ALL EQUIPMENT SHALL BE INSTALLED WITH SUFFICIENT ACCESS TO CONTROLS, FILTERS, ELECTRIC MOTORS, ETC. CONTRACTOR SHALL PROVIDE ACCESS PANELS WHERE REQUIRED - COORDINATE LOCATIONS WITH ARCHITECT. 8. COORDINATE ACCESS TO ALL DAMPERS, VALVES, AND OTHER SERVICEABLE EQUIPMENT WITH ARCHITECT. 9. PROVIDE BIRD SCREENS AT ALL INTAKE AND EXHAUST OPENINGS WITH BACKDRAFT DAMPERS PER CAL GREEN. 10. FLASH AND COUNTER FLASH ALL ROOF PENETRATIONS AS REQUIRED TO SEAL WEATHER TIGHT. (SEE ROOFING DETAILS AND SPECIFICATIONS). 11. PROVIDE UL-LISTED/APPROVED THROUGH PENETRATION FIRE-STOPPING AT ALL DUCT, PIPE AND CONDUIT PENETRATIONS OF FIRE-RATED WALLS, FLOORS, CEILING/FLOOR OR CEILING/ROOF ASSEMBLIES AND SHAFTS COMPLIANT WITH CHAPTER 7 OF THE 2022 CALIFORNIA BUILDING CODE. 12. LIMITING TRANSMISSION OF NOISE AND VIBRATIONS IS EXTREMELY IMPORTANT. CONTRACTOR TO PAY PARTICULAR ATTENTION THAT PIPING, EQUIPMENT, AND DUCTWORK ARE INSTALLED SO AS NOT TO CHATTER OR RUB AGAINST OTHER MATERIALS, EQUIPMENT OR BUILDING STRUCTURE. PROVIDE ISOMODE PADS, INSULATION OR OTHER SUITABLE MATERIALS TO AVOID DIRECT CONTACT AND NOISY CONDITIONS. SUFFICIENT CLEARANCES OF PIPING AND ITS ASSOCIATED COMPONENTS SHALL BE PROVIDED FROM ADJACENT JOIST, STUDS, BEAMS, COLUMNS DRYWALL, ETC. TO ALLOW FOR PIPE MOVEMENT DUE TO THERMAL EXPANSION AND STILL NOT COME IN CONTACT WITH STRUCTURE. INSULATION SHALL BE CONTINUOUS THROUGH PIPE HANGERS (PROVIDE SHEET METAL INSULATION SHIELD AT EACH HANGER). 13. WHERE JOIST, STUD OR BEAM PENETRATIONS ARE REQUIRED, SIZE TO PROVIDE ADEQUATE CLEARANCE FROM PIPE BUT DO NOT SIZE FOR INSULATION. PROVIDE “ACCOUSTO-PLUMB” ISOLATORS AT EACH SUCH PIPE PENETRATION AND BUTT ENDS OF INSULATION TIGHT AGAINST FRAMING TO ELIMINATE ANY CONNECTIVE HEAT LOSS. REVIEW ALL SUCH PENETRATIONS WITH ARCHITECT AND GENERAL CONTRACTOR BEFORE DRILLING OR NOTCHING. SEE STRUCTURAL DRAWINGS FOR CRITERIA ON JOIST PENETRATIONS - VERIFY WITH GENERAL CONTRACTOR. 14. PROVIDE DIELECTRIC INSULATING CONNECTIONS BETWEEN ALL DISSIMILAR METALS. 15. NOTIFY ARCHITECT AND GENERAL CONTRACTOR 48 HOURS IN ADVANCE BEFORE ANY TESTING. 16. PROVIDE DUCT AND PIPE INSULATION AND THERMOSTATS PER TITLE 24 REQUIREMENTS AND SPECIFICATIONS. 17. PER CALIFORNIA GREEN BUILDING STANDARDS CODE (PART 11 OF TITLE 24, CALIFORNIA CODE OF REGULATIONS): A. PROTECT DUCT OPENINGS AND MECHANICAL EQUIPMENT DURING CONSTRUCTION. B. LIMIT USE OF PERMANENT HVAC DURING CONSTRUCTION TO CONDITIONING NECESSARY FOR MATERIAL AND EQUIPMENT INSTALLATION. IF PERMANENT HVAC IS USED DURING CONSTRUCTION, INSTALL MERV-8 FILTERS ON RETURNS, AND REPLACE ALL FILTERS IMMEDIATELY PRIOR TO OCCUPANCY, OR, IF THE BUILDING IS OCCUPIED DURING ALTERATION, AT THE CONCLUSION OF CONSTRUCTION. C. PROVIDE AT LEAST MERV-13 FILTERS IN AIR HANDLERS CONDITIONING REGULARLY OCCUPIED SPACES OF MECHANICALLY VENTILATED BUILDINGS. D. DO NOT INSTALL EQUIPMENT THAT CONTAINS CFCS OR HALONS. E. PROVIDE THE BUILDING OWNER OR REPRESENTATIVE WITH DETAILED OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES OF GUARANTIES/WARRANTIES FOR EACH SYSTEM. O & M INSTRUCTIONS SHALL BE CONSISTENT WITH OSHA REQUIREMENTS IN CCR, TITLE 8, SECTION 5142, AND OTHER RELATED REGULATIONS. 18. ALL EXHAUST FAN DISCHARGES SHALL BE MINIMUM 3'-0" FROM ANY OPERABLE WINDOW WITH BACKDRAFT DAMPERS PER CAL GREEN. 19. ALL EXHAUST FAN DISCHARGES SHALL BE MINIMUM 10'-0" FROM A FORCED AIR INLET. 20. COMPLY WITH CHAPTER 7 & 7A OF 2022 CBC. 21. COORDINATE WITH ELECTRICAL DRAWINGS FOR POWER AND WIRING INFORMATION. 1. PROVIDE ROOFTOP ENERGY RECOVERY VENTILATOR FOR FRESH AIR TO OFFICES AND GROUP SPACES AND EXHAUST FOR PUBLIC RESTROOMS. 2. PROVIDE VRV SYSTEM FOR CONDITIONING OF OFFICES AND GROUP SPACES. 3. PROVIDE DUCTED FAN COIL AND ENERGY RECOVERY VENTILATOR FOR HVAC TO NC SLEEPING ROOMS. 4. PROVIDE WALL MOUNTED AC UNITS FOR COOLING TO ELECTRICAL AND DATA ROOMS. 5. PROVIDE ROOFTOP GREASE FAN FOR TYPE I GREASE HOOD IN COMMERCIAL KITCHEN. 6. PROVIDE MAKEUP AIR UNIT AND DUCTED FAN COIL FOR HVAC TO COMMERCIAL KITCHEN. FS FS FD FD FD FIRE DAMPER 1M-11M-1 AC1 A XXX, FD 12x12# GENERAL MECHANICAL NOTES SHEET INDEX SCOPE OF WORK APPLICABLE CODES M-001 MECHANICAL TITLE SHEET M-002 MECHANICAL SCHEDULES M-201 LEVEL 01 - MECHANICAL PLAN M-203 ROOF - MECHANICAL PLAN VENTILATION CALCULATIONS HRV AIR FLOW RELATIONSHIPS
PROJECT NUMBER: CLIENT: PHASE: SHEET TITLE: SHEET: All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer. REVISIONS: 2222 NE OREGON ST. SUITE 101 PORTLAND, OR 97232 PHONE: 503.702.2575 WWW.SALAZARCH.COM DRAWN BY: CHECKED BY: DATE CREATED: Salazar Architect, Inc. # DATE DESCRIPTION 2321 SHELTER II AT EAST BEAMER 1901 EAST BEAMER STREET WOODLAND, CA 95776 APN:027-360-042 THURMOND CONSULTING 2122 NATOMAS CROSSING SUITE 200-288 SACRAMENTO, CA 95834 75% CONSTRUCTION DOCUMENTS 10/02/24 M-002 EDC EDC MECHANICAL TITLE SHEET
20x20 20x20 20x20
20x20
20x20
20x20 3'-6" DS DSDSDS
A
C
1 D
E
G
H
F
2 5 12
B 113 SF NC-1 140 115 SF NC-2 139 115 SF NC-3 138 115 SF NC-4 137 115 SF NC-5 136 115 SF NC-6 135 115 SF NC-7 134 115 SF NC-8 133 115 SF NC-9 132 4 K 227 SF CASE MANAGEMENT 112 216 SF CASE MANAGEMENT 111 60 SF DATA 110 204 SF ADMINISTRATION OFFICE 109 143 SF INTAKE 102 122 SF PEST CONTROL 103 577 SF GROUP COUNSELING 124 105 SF STORAGE LINEN 115 121 SF UTILITY / STORAGE 117 425 SF LAUNDRY 114 650 SF MEN'S BATHROOM 118 131 SF CLIENT STORAGE 116 105 SF OFFICE 107 81 SF STAFF RESTROOM 108 410 SF WOMEN'S BATHROOM 148 131 SF ADMINISTRATION OFFICE 128 237 SF MEN'S BATHROOM-NC 147 238 SF WOMEN'S BATHROOM-NC 144 62 SF MEDICATION 127 104 SF COUNSELING OFFICE 1 143 80 SF MECHANICAL UTILITY 145 78 SF MAINTENANCE ROOM 146 87 SF LAUNDRY 129 104 SF COUNSELING OFFICE 2 142 6 7
8 9 10 11 440 SF DAY ROOM 141 102 SF WAITING AREA 125 921 SF COMMERCIAL KITCHEN 119 100 SF FIRE 122 100 SF ELECTRICAL 123 L 144 SF NC-11 154 144 SF NC-12 153 142 SF NC-13 152 142 SF NC-14 151 3 281 SF WAITING AREA 105 168 SF ENTRY 101 299 SF HALLWAY 5 106 126 SF HALLWAY 2 126 598 SF HALLWAY 3 130 914 SF HALLWAY 1 113 241 SF HALLWAY 4 149 116 SF NC-10 131 W
D W/D W/D W/D W/D W/D W/D
W
W
D
D
J 6.1 7B 7A 7A 7B 7B 7B 7B 7B 7B 7B 7B 7A 8A 5B 10 10 10 10 10 10 10 10 10 10 10 1010 10 1010 10 7A 5B 5B 5B 5B 5B 5B5B 7A 5B7A 7A 7A 7B 5A5B5B 7A 5B 7A 7A 7A 5A 7B 7B 7B 6B 6B 5B5B 5B5B 5B TYP 7B 7B 7B 7B 7B 7B 8A 8A 8A 5A 5A 5A 5A 5A 5A6B 7A 7A 5A 5A5A 7A 7A 7A 7A 7A 5A 7A 7A 7A 7A 8A 8A 8A 6B 5B W1 W3 W3 W1 W3 W3 W1 W3 W3 W3 W1 W3 W3 W1 W3 W4 W4 W4 W4 W4 W4 W4 W4 W4 W1 W1 W1 W1 W1 W1 W6 W6 W6 W6 W6 W3 W1 W3 W3 W1 W3 W3 W1 W1 W6 W6 W6 7A 7A 7A 7A 7A7A EXISTING ROOF PROJECTION TO BE DEMOLISHED PER COORDINATION WITH FIRE MARSHALL W5 W7 W7 W7 W7 W6 87 SF PANTRY 119E 174 SF REFRIGERATOR 119F 97 SF FREEZER 119G 57 SF RESTROOM 119C 53 SF OFFICE 119B 5B W6 W6 W6 5A 5B EF 2 DBF
1 TYP. 2 AC
2 AC
1 FC
1 6"Ø 10"Ø 10"Ø 6"Ø EF
1 SEE FOOD SERVICE PLANS FOR CONNECTION TO TYPE I HOOD SEE M-203 PLAN FOR CONTINUATION ON ROOF 14"Ø GREASE DUCT TO ROOFTOP EF-3 E 6" 74
S 6" 45
S 6" 45
S 6" 45
S 8" 172
S 10" 250
R 8" 125
S 10" 334
S 10" 334
S 6" 40
S 6" 40
S 8" 200
S 6" 78
S 6" 80
S 6" 100
R 10" 305
R 10" 305
S 6" 40 S 8" 130
S 4" 20
S 4" 29
S 4" 30
S 4" 30
S 4" 30
S 4" 30
S 4" 30
S 4" 30
S 4" 30
E 6" 30
S 6" 30
E 6" 30
S 6" 30
E 6" 30
S 6" 30
E 6" 30
S 6" 30
R 14" 668
O 18" 1750 RA TO ABOVE WITH 1" ACOUSTIC LINING FOR FIRST 10' OF DUCT FROM FC-K1 ON ROOF SA FROM ABOVE WITH 1" ACOUSTIC LINING FOR FIRST 10' OF DUCT FROM FC-K1 ON ROOF16"x10" 10"Ø 10"Ø MAKE UP AIR FROM ABOVE WITH 1" ACOUSTIC LINING FOR FIRST 10' OF DUCT FROM MAU-1 ON ROOF 10"Ø 26"x11" 16"x10" S 6" 80
T 6" 80 EF 6"Ø 4 10"Ø 6"Ø 6"Ø 8"Ø 12"x10" or 12"Ø 10"Ø 8"Ø 6"Ø T 6" 80
T 6" 80 16"x6"
R 10" 360
S 10" 360
S 10" 360 36"x18"x6" 12"x6"
T 12" 448
T 6" 74
T 6" 80 8"x6" 6"Ø 18"x6" 10"x6" 10"x6" 8"x6" 8"x6" 12"x6" 12"x6" 22"x6" 10"x6" 4"Ø 6"Ø 6"Ø 8"x6" 8"x6" 8"x6" 12"x6" 6"Ø 6"Ø 4"Ø 8"Ø 8"Ø 6"Ø E 10" 298
R 8" 210
R 8" 210
R 12" 572
R 4" 30 1" ACOUSTIC LINING FOR FIRST 10' OF DUCT FROM UNIT. (TYP) 6"Ø R 4" 30
R 4" 30
R 4" 30
S 4" 30
S 4" 30
R 4" 30
R 4" 30
R 4" 30
R 4" 30
R 4" 30
R 4" 30
R 4" 29 12"x6" 4"Ø 6"Ø 6"Ø 8"x6" 8"x6" 8"x6" 4"Ø 6"Ø 8"x6" S 6" 45S 6" 45 6"Ø6"Ø6"Ø 8"Ø LAUNDRY ROOM MAKE UP AIR SUPPLY DIFFSUER. 20"x6" 18"Ø (OR 26"x11") LAUNDRY ROOM MAKE UP AIR INLET LOUVER ABOVE. 1750 CFM PASSIVE AIR ENTRY WITH FABRIC BACK DRAFT DAMPER. SEE M-203 FOR CONTINUATION 8"Ø HRV 2FC
2 10"Ø 10"Ø 10"Ø
S 12" 572 HRV
3 E 12" 448 DBF EXHAUST TERMINATION ABOVE. SEE M-203 FOR CONTINUATION S 8" 210
S 8" 210
O 10" 298 12"x10" 6"Ø8"Ø8"Ø RESTROOM EXHAUST TERMINATION ABOVE. SEE M-203 FOR CONTINUATION HRV 1 12"x10"
S 4" 30
R 10" 360 16"x6" 16"x6" 16"x6" DUCT CONNECTIONS FROM UNIT ABOVE. 36"x18"x6" 10"x6" 18"x6" 4"Ø 6"Ø 8"x6" 6"Ø S 8" 200 10"x6" DUCT CONNECTIONS FROM UNIT ABOVE. 1" ACOUSTIC LINING FOR FIRST 10' OF DUCT (TYP) R 10" 307 12"x6" DUCT CONNECTIONS FROM UNIT ABOVE.36"x36"x6" 36"x36"x6" 4"Ø 36"x22"x6" 36"x22"x6" 20"x6" 10"x6" 10"x6" 10"x6" 10"x6" 18"x6" 18"x6" 10"x6" 1" ACOUSTIC LINING FOR FIRST 10' OF DUCT (TYP) UNDERGROUND REFRIGERANT LINES IN 4" PVC CONDUIT REFRIGERANT LINES DROP TO UNDERGROUND 4" PVC CONDUIT REFRIGERANT LINE RISERS FROM 4" PVC CONDUIT TO UNIT PROJECT NUMBER: CLIENT: PHASE: SHEET TITLE: SHEET: All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer. REVISIONS: 2222 NE OREGON ST. SUITE 101 PORTLAND, OR 97232 PHONE: 503.702.2575 WWW.SALAZARCH.COM DRAWN BY: CHECKED BY: DATE CREATED: Salazar Architect, Inc. # DATE DESCRIPTION 2321 SHELTER II AT EAST BEAMER 1901 EAST BEAMER STREET WOODLAND, CA 95776 APN:027-360-042 THURMOND CONSULTING 2122 NATOMAS CROSSING SUITE 200-288 SACRAMENTO, CA 95834 75% CONSTRUCTION DOCUMENTS 10/02/24 M-201 EDC EDC LEVEL 01 - MECHANICAL PLAN 1 SCALE: LEVEL 01 - MECHANICAL PLAN 3/16" = 1'-0"
N
AC 1 DEGHF 2 5 12 B 44 K 6 7 8 9 10 11 L 3 J 6.1 SHED ROOF 4293 SF POTENTIAL FUTURE PV LOCATION 2500 SF MAX LOW ROOF 6675 SF MECHANICAL EQUIPMENT LOCATION 1 1/2" / 1'-0" VALLEY
RIDGE VALLEY VALLEY VALLEY RIDGEVALLEY ROOF ACCESS HATCH, CRICKET AT HIGH SIDE PARAPET / STEM WALL FACE OF WALL BELOW -TYP ROOF AREA TO BE REINFORCED TO SUPPORT MECHANICAL AND PLUMBING EQUIPMENT ROOF AREA TO BE REINFORCED TO SUPPORT MAU, SEE MECHANICAL AND STRUCTURAL VENTILATED RAFTER SPACE PER 1202.2.1: 1029 SF /150 = 7 SF MIN FREE AREA TOTAL PROVIDED = 3.5 SF FREE AREA AT LOW EAVE VENTILATED RAFTER SPACE PER 1202.2.1: 1029 SF /150 = 7 SF MIN FREE AREA TOTAL PROVIDED = 3.5 SF FREE AREA AT HIGH EAVE AT WALL AT PARAPET CAP ROOF EQUIPMENT -TYP, SEE 1/4" / 1'-0" MECHANICAL AND PLUMBING
1/4" / 1'-0" STEM WALL 8" ABOVE ROOF SURFACE MIN 1/4" / 1'-0" 1/4" / 1'-0" VALLEY VALLEY VALLEY 7.6 7.6 7.6 7.6 ROOF AREA TO BE REINFORCED TO SUPPORT CONDSENER, SEE MECHANICAL AND FOOD SERVICE CU3 EF3 CU2 CU1 CUK2 14"Ø GREASE DUCT FROM TYPE I HOOD IN COMMERCIAL KITCHEN SEE M-201 PLAN FOR CONTINUATION IN HIGH CEILING MAU1FCK1 RA FROM BELOW WITH 1" ACOUSTIC LINING FOR FIRST 10' OF DUCT FROM UNIT SA TO BELOW WITH 1" ACOUSTIC LINING FOR FIRST 10' OF DUCT FROM UNIT REFRIGERATION CONDENSER REFERENCE KITCHEN PLANS FOR ADDITIONAL INFORMATION 6"Ø RESTROOM EXHAUST VENT TERMINATION LAUNDRY ROOM MAKE UP AIR INLET LOUVER. 1750 CFM PASSIVE AIR ENTRY WITH FABRIC BACK DRAFT DAMPER. SEE M-201 FOR CONTINUATION DBF EXHAUST TERMINATION. SEE M-201 FOR CONTINUATION RESTROOM EXHAUST TERMINATION. SEE M-201 FOR CONTINUATION HP1 HP3 HP2 PROJECT NUMBER: CLIENT: PHASE: SHEET TITLE: SHEET: All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer. REVISIONS: 2222 NE OREGON ST. SUITE 101 PORTLAND, OR 97232 PHONE: 503.702.2575 WWW.SALAZARCH.COM DRAWN BY: CHECKED BY: DATE CREATED: Salazar Architect, Inc. # DATE DESCRIPTION 2321 SHELTER II AT EAST BEAMER 1901 EAST BEAMER STREET WOODLAND, CA 95776 APN:027-360-042 THURMOND CONSULTING 2122 NATOMAS CROSSING SUITE 200-288 SACRAMENTO, CA 95834 75% CONSTRUCTION DOCUMENTS 10/02/24 M-203 EDC EDC ROOF - MECHANICAL PLAN 1 SCALE: ROOF - MECHANICAL PLAN 3/16" = 1'-0" N
PROJECT NUMBER: CLIENT: PHASE: SHEET TITLE: SHEET: All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer. REVISIONS: 2222 NE OREGON ST. SUITE 101 PORTLAND, OR 97232 PHONE: 503.702.2575 WWW.SALAZARCH.COM DRAWN BY: CHECKED BY: DATE CREATED: Salazar Architect, Inc. # DATE DESCRIPTION 2321 SHELTER II AT EAST BEAMER 1901 EAST BEAMER STREET WOODLAND, CA 95776 APN:027-360-042 THURMOND CONSULTING 2122 NATOMAS CROSSING SUITE 200-288 SACRAMENTO, CA 95834 75% CONSTRUCTION DOCUMENTS 10/02/24 E-001 EDC EDC ELECTRICAL TITLE SHEET GENERAL ELECTRICAL NOTES SCOPE OF WORK APPLICABLE CODES SHEET INDEX ABBREVIATIONS 1. ALL WORK IS TO BE PERFORMED IN STRICT COMPLIANCE WITH THE NATIONAL ELECTRIC CODE, STATE LAWS, AND ALL OTHER REGULATIONS GOVERNING WORK OF THIS NATURE. 2. CONTRACTOR SHALL FAMILIARIZE HIMSELF WITH THE EXISTING JOB CONDITION. HE SHALL EXAMINE CONSTRUCTION DRAWINGS AND SPECIFICATIONS AND SHALL HAVE HAD VISITED THE CONSTRUCTION SITE, PRIOR TO SUBMITTING HIS BID PROPOSAL. HE SHALL BE FAMILIAR WITH THE EXISTING CONDITIONS UNDER WHICH HE WILL HAVE TO OPERATE AND WHICH WILL IN ANY WAY AFFECT THE WORK UNDER THIS CONTRACT. NO SUBSEQUENT ALLOWANCE WILL BE MADE IN THIS CONNECTION IN BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLIGENCE ON HIS PART. DETERMINE THE SEQUENCE OF CONSTRUCTION THROUGHOUT THE PROJECT, INCLUDING TEMPORARY FACILITIES AND CONNECTIONS REQUIRED FOR THE DURATION OF THE PROJECT. 3. THE CONTRACTOR SHALL SECURE ALL PERMITS OR APPLICATIONS, AND PAY ANY AND ALL FEES AS REQUIRED. 4. EXISTING ARCHITECTURAL SURFACES DISTURBED DURING CONSTRUCTION SHALL BE PATCHED AND PAINTED TO MATCH EXISTING. 5. WORK SHOWN IN THESE PLANS ARE NEW, UON. INSTALLATION SHALL BE CONCEALED. WHERE NOT POSSIBLE, CONTRACTOR SHALL OBTAIN APPROVAL FROM ARCHITECT AND ENGINEER FOR EXPOSED INSTALLATION. A WRITTEN APPROVAL IS REQUIRED. USE SURFACE RACEWAYS, WIREMOLD, OR EQUAL. ALL ELECTRIC MATERIALS, DEVICES, AND EQUIPMENT FOR THE PROJECT SHALL BE NEW AND U.L. APPROVED 6. ALL CONDUIT SHALL BE 3/4" MINIMUM. ALL CONDUIT SHALL BE RUN PARALLEL TO EXISTING SURFACES. WHEN CONDUIT CROSSES CORRIDORS OR ROOMS IT SHALL BE DONE PERPENDICULAR TO WALLS. 7. PAINT ALL SURFACE MOUNTED CONDUITS AND FITTINGS TO MATCH ADJACENT SURFACE. CONFIRM COLOR WITH OWNER. 8. ALL EXPOSED CONDUITS SHALL BE MOUNTED WITH 2-HOLE STRAPS. 9. CONDUIT CONNECTORS SHALL BE COMPRESSION TYPE. 10. SEAL ALL CONDUIT PENETRATIONS THROUGH FIRE RATED WALLS. FURNISH AND INSTALL FIRE RATED BACKBOXES AS REQUIRED TO MAINTAIN FIRE RATING OF CEILING OR WALLS WHERE RECESSED ELECTRIC EQUIPMENT SUCH AS LIGHT FIXTURES, SWITCHES, RECEPTACLES, PANEL, ETC. ARE INSTALLED IN RATED WALL OR CEILINGS. PENETRATIONS OF FIRE RATED WALLS, CEILINGS, OR FLOORS SHALL COMPLY WITH CBC CHAPTER 7 REQUIREMENTS. IN WALLS AND PARTITIONS THAT ARE FOR FIRE RESISTIVE CONSTRUCTION, OPENINGS FOR STEEL ELECTRICAL OUTLET BOXES SHALL NOT EXCEED 16 SQUARES INCHES. IN ADDITION, THE AGGREGATE AREA OF SUCH OPENING SHALL NOT EXCEED 100 SQUARE INCH FOR ANY 100 SQUARE FEET OF WALL OR PARTITION. OUTLET BOXES ON OPPOSITE SIDES OF THE WALLS OR PARTITION SHALL BE SEPARATED BY A HORIZONTAL DISTANCE OF AT LEAST 24 INCHES, OR BE PROVIDED WITH FIRE PUTTY. 11. ALL NEW WIRING SHALL BE IN CONDUIT. COORDINATE ROUTING OF CONDUIT WITH ARCHITECT AND STRUCTURAL FOR OPENINGS IN WALLS AND ANY NOTCHING OF JOISTS. 12. THE ELECTRICAL PLANS ARE SCHEMATIC IN NATURE AND ARE NOT INTENDED TO SHOW ALL OF THE ARCHITECTURAL DETAILS OR SPECIFICS OF ELECTRICAL CONSTRUCTION. TAKE ALL DIMENSIONS FROM THE ARCHITECTURAL DRAWINGS. BEFORE ROUGH-IN, VERIFY ALL MOUNTING HEIGHTS AND EXACT LOCATIONS FOR ALL EQUIPMENT ELECTRICAL CONNECTIONS, STUB-UPS, RECEPTACLES, OUTLETS, CONDUIT RUNS, ETC. WITH ARCHITECT AND OWNER. PLACE DEVICES LOCATED ABOVE COUNTERS, SHELVING, ETC. AND IN BATHROOMS SO AS NOT TO CONFLICT WITH EDGES OF WAINSCOTING, COUNTER SPLASH, SHELVING, ETC. ARCHITECTURAL SHEETS SHALL GOVERN. SEE ELECTRICAL SECTION OF ARCHITECTURAL SPECIFICATION FOR ADDITIONAL INFORMATION. 13. PULLROPES: ANY RACEWAY WITHOUT CABLE OR WIRE SHALL BE INSTALLED WITH MINIMUM 200 POUND TEST PULL LINE AND LARGER. 14. ALL DEVICES AND EQUIPMENT INSTALLED OUTDOORS OR EXPOSED TO THE WEATHER SHALL BE OF WEATHERPROOF CONSTRUCTION. ALL WALL PENETRATIONS TO EXTERIOR WALLS SHALL BE SEALED WATER TIGHT. 15. ALL EQUIPMENT SHALL BE LISTED AND LABELED BY A NATIONALLY RECOGNIZED TESTING LABORATORY AND SHALL BE INSTALLED AS PER LISTING OR LABELING (I.E. MAXIMUM FUSE SIZE MEANS FUSE PROTECTION IS REQUIRED). 16. ALL EQUIPMENT MANUFACTURERS SHALL BE NOTED IN DRAWINGS. SUBSTITUTIONS ARE PERMITTED BUT MUST BE APPROVED EQUAL. 17. CONNECTIONS TO MECHANICAL EQUIPMENT SHALL BE MADE WITH A MINIMUM OF 24" OF WEATHERPROOF FLEXIBLE CONDUIT TO PREVENT SOUND AND VIBRATION TRANSMISSION TO THE STRUCTURE. COORDINATE ALL MOTOR OVERLOADS AND/OR FUSES FURNISHED BY THIS CONTRACT WITH THE ACTUAL EQUIPMENT INSTALLED. SIZE OVERLOADS BASED ON MOTOR NAMEPLATE FULL LOAD CURRENT AND SERVICE FACTOR. FUSES FOR MOTOR AND TRANSFORMER CIRCUITS SHALL BE DUAL ELEMENT. FUSES FOR OTHER "NON-INRUSH" LOADS SHALL BE FAST ACTING. ALL FUSES SHALL BE CURRENT LIMITING CLASS RK5 OR CLASS L, UON. CONTRACTOR SHALL COORDINATE WITH ALL TRADES FOR MANUFACTURER INSTALLATION REQUIREMENTS. 18. SEE MECHANICAL AND PLUMBING DRAWINGS FOR LOCATION OF FANS AND WATER HEATERS. 19. ALL ELECTRICAL WORK SHALL BE COORDINATED WITH THE MECHANICAL WORK AS CALLED FOR IN MECHANICAL SPECIFICATIONS. 20. GROUNDING CONDUCTORS ARE GENERALLY NOT SHOWN. GROUND AND BOND ALL EQUIPMENT, RACEWAYS, MOTORS, PANELBOARDS AND SWITCHBOARDS, ETC. IN ACCORDANCE WITH NEC ARTICLE 250. 21. FIELD MOUNTED DEVICES SUCH AS SWITCHES, MOTOR STARTERS, RECEPTACLES, ETC., ARE SHOWN IN THEIR APPROXIMATE LOCATION. SWITCH MOUNTING HEIGHT SHALL BE 48" ABOVE FINISHED FLOOR AND RECEPTACLE MOUNTING HEIGHT SHALL BE 18" ABOVE FINISHED FLOOR. CONTRACTOR SHALL COORDINATE WITH ALL TRADES FOR MANUFACTURER INSTALLATION REQUIREMENTS. 22. ELECTRICAL CONTRACTOR TO PROVIDE EXPANSION FITTINGS AT ALL EXPANSION JOINT LOCATION. USE STEEL FLEX 6 FEET EACH SIDE OF THE JOINT AND TERMINATE IN A PULLBOX AT EACH END, OR OTHER APPLIED METHODS. 23. ALL LIGHTING FIXTURE LOCATIONS AND ROUTING SHALL BE REVIEWED BY ARCHITECT PRIOR TO ROUGH-IN. 24. ALL ELECTRICAL EQUIPMENT SHALL BE INSTALLED TO MAINTAIN A MINIMUM OF 36" CLEARANCE PER NEC ARTICLE 110.26. 25. PENETRATIONS OF FIRE RATED WALLS CEILINGS OR FLOORS SHALL COMPLY WITH CBC CHAPTER 7 REQUIREMENTS. 26. WHERE OUTLET BOXES ARE INSTALLED WITHIN RATED ASSEMBLIES, PROVIDE 3M MOLDABLE PUTTY PADS OR EQUAL TO MAINTAIN FIRE RATED ASSEMBLIES. 27. ALL RECEPTACLES SHALL BE GROUNDING TYPE. 28. ALL RECEPTACLES INSTALLED IN BATHROOMS AND KITCHENS SHALL HAVE GROUND-FAULT CIRCUIT INTERRUPTER PROTECTION AS REQUIRED BY THE NATIONAL ELECTRIC CODE. 29. CONTRACTOR TO CONFIRM EXACT LOCATION OF METERS WITH ELECTRIC UTILITY. 30. SUBMIT TO THE OWNER CERTIFICATES OF INSPECTIONS IN DUPLICATE FROM AN APPROVED INSPECTION AGENCY UPON COMPLETION. 31. PERFORMANCE AND WITNESSING OF TESTS: A. THE CONTRACTOR SHALL FURNISH ALL INSTRUMENTS AND QUALIFIED PERSONNEL OR FIRM TO PERFORM ALL REQUIRED TESTS. B. ALL NEW AND RECONNECTED ELECTRICAL CIRCUIT SHALL BE TESTED TO INSURE CIRCUIT CONTINUITY, INSULATION RESISTANCE, PROPER SPLICING AND GROUNDING IN ACCORDANCE WITH THE LATEST STANDARDS AS STATED ABOVE. BEFORE CONNECTING POWER CABLES TO MOTORS, THE INSULATION RESISTANCE OF ALL MOTOR WINDINGS SHALL BE TESTED IN ACCORDANCE WITH THE ABOVE STANDARDS. C. ANY CONTRACTOR FURNISHED AND/OR INSTALLED SPLICE, RECOMMENDED VOLTAGE AND INSULATION RESISTANCE TESTS, SHALL BE CONNECTED OR REPLACED BY THE CONTRACTOR AT HIS EXPENSE. D. NO EQUIPMENT SHALL BE ENERGIZED UNTIL ALL TESTS AND ADJUSTMENTS HAVE BEEN MADE. E. THREE COPIES OF ALL TEST RESULTS SHALL BE DELIVERED TO THE OWNER. 32. IN DOUBLE-STUD PARTITIONS, CONDUIT SHOULD NOT BRIDGE STUD ROWS. CONDUIT SHOULD BE ROUTED ONLY IN THE STUDS ON THE SIDE OF THE UNIT SERVED AND SHOULD NOT BE PLACED IN THE GAP BETWEEN STUD ROWS. 33. OUTLET BOXES ON OPPOSITE SIDES OF DEMISING PARTITIONS SHOULD BE SEPARATED BY AT LEAST 16 INCHES AND PROVIDE BACKING EQUIVALENT TO LOWRY'S OUTLET BOX PADS. WHEN ELECTRICAL BOXES MUST BE BACK-TO-BACK OR LESS THAN 16" OF EACH OTHER, INSTALL GYPSUM BOARD CENTERED VERTICALLY TO BOX FROM STUD TO STUD. 34. DO NOT ALLOW ELECTRICAL CONDUIT OR BOXES TO COME INTO CONTACT WITH PLUMBING. 1 FOR REQUIRED MOUNTING HEIGHTS, SEE DETAIL: E-801 SYMBOLS (NOT ALL USED) # = DETAIL NUMBER X = SHEET NUMBER DEMOLITION WORK MATCH LINE ENLARGED PLANS BRANCH CIRCUIT WIRING IN CONDUIT CONCEALED IN CEILING OR WALL. BRANCH CIRCUIT WIRING IN CONDUIT CONCEALED UNDER FLOOR OR UNDERGROUND. BRANCH CIRCUIT HOMERUN TO PANEL. CONCEALED IN CEILING SPACE OR WHERE POSSIBLE. REQUIRED WORKING CLEARANCE PER NEC 110.26. LIGHT FIXTURE TAG (X = FIXTURE TYPE). REFER TO LIGHTING SCHEDULE. JUNCTION OR OUTLET BOX MOUNTED ABOVE CEILING WITH BLANK COVER. · X = JUNCTION BOX TYPE: CU = CONDENSING UNIT, EF = EXHAUST FAN, ERV = ENERGY RECOVERY VENTILATOR, FC = FAN COIL, KRH = KITCHEN RANGE HOOD, HP = HEAT PUMP, OAF = OUTSIDE AIR FAN, AND SF = SUPPLY FAN. 1" CONDUIT HOMERUN TO PANEL EV FOR FUTURE EV CHARGING STATION AT EV CAPABLE SPACES, BOLLARD MOUNT OR WALL MOUNT. HORSEPOWER RATED TOGGLE SWITCH WITH THERMAL OVERLOADS. FUSED DISCONNECT SWITCH WITH DUAL ELEMENT FUSED (UON). DUPLEX RECEPTACLE 20A, 125V, 3WG, NEMA 5-20R, +15" (UON). NEW INTERIOR RECEPTACLES SHALL BE TAMPER RESISTANT TYPE. REFER TO PANEL SCHEDULES FOR AFCI TYPE RECEPTACLE APPLICATION. · X = RECEPTACLE TYPE: WP = GFCI AND WEATHERPROOF WITH IN-USE COVER, D = DEDICATED, GFCI = WITH GROUND FAULT CIRCUIT INTERRUPTER, AND OS = OCCUPANCY SENSOR CONTROLLED. DUPLEX RECEPTACLE 20A, WITH GROUND FAULT CIRCUIT INTERRUPTER, +15" (UON). (WP = WEATHERPROOF) DUPLEX RECEPTACLE 20A, ABOVE COUNTER OR +42" AFF. DOUBLE DUPLEX RECEPTACLE (2) NEMA 5-20R, WITH GROUND FAULT CIRCUIT INTERRUPTER, ABOVE COUNTER. DUPLEX RECEPTACLE, 20A, FLUSH MOUNTED FLOOR BOX. NEW INTERIOR RECEPTACLES SHALL BE TAMPER RESISTANT TYPE. REFER TO PANEL SCHEDULES FOR AFCI TYPE RECEPTACLE APPLICATION. QUADPLEX RECEPTACLE NEMA 5-20R , FLUSH MOUNTED FLOOR BOX. NEW INTERIOR RECEPTACLES SHALL BE TAMPER RESISTANT TYPE. REFER TO PANEL SCHEDULES FOR AFCI TYPE RECEPTACLE APPLICATION. DOUBLE DUPLEX RECEPTACLE (2) NEMA 5-15R. DOUBLE DUPLEX RECEPTACLE (2) NEMA 5-20R, SPLIT-WIRED, WITH GROUND FAULT CIRCUIT INTERRUPTER. 240V OR 208V RECEPTACLE OR OUTLET. COORDINATE ELECTRICAL CONNECTION WITH FINAL EQUIPMENT SELECTION. PANELBOARD: 120/240V, 1 PHASE, 3 WIRE SURFACE MOUNTED; 120/208V, 3 PHASE, 4 WIRE FLUSH/SURFACE MOUNTED. LOW VOLTAGE DIMMER SWITCH FOR MULTIPLE ZONES. (# = NUMBER OF CONTROLLED ZONE AND a,b = ZONE) SINGLE POLE SWITCH AND BOX WITH STANDARD MANUAL ON / OFF IN COMBINATION OF SWITCH TYPE LISTED BELOW, WALL MOUNTED, +48" AFF TO THE TOP OF THE BOX, UON. · X = SWITCH TYPE: BLANK = MANUAL ON / OFF ONLY, 3 = THREE-WAY, D = DIMMER, OS = OCCUPANCY SENSOR, VS = VACANCY SENSOR, AND WP = WEATHERPROOF. SINGLE POLE SWITCH AND BOX WITH LIGHTING SENSOR AND DIMMING CAPABILITY, WALL MOUNTED, +48" AFF TO THE TOP OF THE BOX, UON. · SWITCH TYPE: OSD = OCCUPANCY SENSOR WITH DIMMER, AND VSD = VACANCY SENSOR WITH DIMMER. THREE-WAY SWITCH WITH DIMMING CAPABILITY, WALL MOUNTED, +48" AFF TO THE TOP OF THE BOX, UON. · a,b = CONTROLLED ZONE (ONLY APPLICABLE TO THREE-WAY SWITCH). LIGHTING SENSOR, CEILING MOUNTED. OS = CONFIGURE FOR OCCUPANCY AND VS = CONFIGURE FOR VACANCY. LIGHTING SENSOR, WALL MOUNTED. OS = CONFIGURE FOR OCCUPANCY AND VS = CONFIGURE FOR VACANCY. LIGHTING SENSOR COMBO OF OCCUPANCY AND DAYLIGHT, CEILING MOUNTED. DAYLIGHTING SENSOR, CEILING MOUNTED. FIRE ALARM SYSTEM SMOKE DETECTOR, CEILING MOUNTED. 120V SMOKE ALARM WITH BATTERY BACKUP. (CO = CARBON MONOXIDE) FIRE ALARM HORN STROBE DEVICE, CEILING MOUNTED, ACTIVATED BY BUILDING SYSTEM. (# = CANDELA RATING) FIRE ALARM STROBE DEVICE, WALL MOUNTED, CONNECTED WITH RELAY BREAK TO SMOKE ALARM AND BUILDING SYSTEM FOR VISUAL NOTIFICATION. (FOR ADA ONLY) FIRE ALARM HORN STROBE DEVICE, WALL MOUNTED, ACTIVATED BY BUILDING SYSTEM. (# = CANDELA RATING) MANUAL PULL STATION, WALL MOUNTED. DATA OUTLET, FLUSH MOUNT IN WALL. (# = NUMBER OF PORTS) PHONE OUTLET, FLUSH MOUNT IN WALL. DATA/PHONE OUTLET, FLUSH MOUNT IN WALL. DATA/PHONE OUTLET, FLUSH MOUNTED FLOOR BOX. TWO DATA OUTLETS, FLUSH IN FINISHED CEILING. RESERVED FOR WIRELESS ACCESS POINT. WIRELESS ACCESS POINTS BY OTHERS. CATV OUTLET, FLUSH MOUNT IN WALL GENERAL SYMBOLS #X X X X X GFCIXTX D# a,b LIGHTING CONTROLS SYSTEM SYMBOLS FIRE ALARM SYSTEM SYMBOLS LOW VOLTAGE SYSTEM SYMBOLS TV ## GFCI OSD POWER SYSTEM SYMBOLS DEFERRED FIRE ALARM SUBMITTAL 1. 2022 BUILDING STANDARD ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R. 2. 2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R. 3. 2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R. 4. 2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R. 5. 2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R. 6. 2022 CALIFORNIA ENERGY CODE, PART 6, TITLE 24 C.C.R. 7. 2022 CALIFORNIA FIRE CODE (CFC), PART 9, TITLE 24, C.C.R. 9. 2022 CALIFORNIA EXISTING BUILDING CODE, PART 10, TITLE 24 C.C.R. 10. 2022 CALIFORNIA "GREEN" BUILDING REQUIREMENTS, PART 11, TITLE 24 C.C.R. 11. 2022 CALIFORNIA REFERENCED STANDARDS CODE, PART 12, TITLE 24, C.C.R. 12. TITLE 19, C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS NFPA 13, AUTOMATIC SPRINKLER SYSTEM, 2022 EDITION NFPA 14, STANDPIPE AND HOSE SYSTEMS, 2022 EDITION NFPA 72, NATIONAL FIRE ALARM CODE, 2022 EDITION LOCAL MUNICIPAL BUILDING CODES (E) EXISTING TO REMAIN (F) FUTURE (N) NEW (RR) REMOVE AND RELOCATE A AMPERE AC ALTERNATING CURRENT ADA AMERICANS WITH DISABILITIES ACT AF AMPERE RATING OF FUSE AFCI ARC FAULT CIRCUIT INTERRUPTER AFF ABOVE FINISHED FLOOR AFG ABOVE FINISHED GRADE AV AUDIO/VISUAL BS BRANCH SELECTOR C CONDUIT CKT CIRCUIT CO CARBON MONOXIDE CU CONDENSING UNIT D/G DISHWASHER AND GARBAGE DISPOSAL D DEDICATED DIM DIMMABLE EC ELECTRICAL CONTRACTOR EF EXHAUST FAN ELEC ELECTRICAL EM EMERGENCY EMT ELECTRICAL METALLIC TUBING ENT ELECTRICAL NONMETALLIC TUBING EV ELECTRIC VEHICLE EVSE ELECTRIC VEHICLE SUPPLIED EQUIPMENT F/I FURNISH AND INSTALL FACP FIRE ALARM CONTROL PANEL FATC FIRE ALARM TERMINAL CAN FC FAN COIL FSD FIRE SMOKE DAMPER G GROUNDING CONDUCTOR GFI GROUND FAULT INTERRUPTER GFCI GROUND FAULT CIRCUIT INTERRUPTER GND GROUND HP HORSEPOWER HVI HEARING AND VISUALLY IMPAIRED IWH INSTANT WATER HEATER JB JUNCTION BOX kVA KILOVOLT AMPS kW KILOWATTS LC LOAD CENTER LF LOW FREQUENCY LTG LIGHTING LTS LIGHTS LV LOW VOLTAGE MC MEDIA CABINET MECH MECHANICAL MTD MOUNTED MV MEDIUM VOLTAGE N NEUTRAL N.E.C. NATIONAL ELECTRICAL CODE NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION NEUT NEUTRAL NIC NOT IN CONTRACT NTS NOT TO SCALE OS OCCUPANCY SENSOR OSD OCCUPANCY SENSOR WITH DIMMER P POLE PB PULL BOX PH, ɸ PHASE PNL PANEL POS POINT OF SALE RSC RIGID STEEL CONDUIT S.A.D. SEE ARCHITECTURAL DRAWINGS S.A.V.D. SEE AUDIO/VISUAL DRAWINGS S.C.D. SEE CIVIL DRAWINGS S.L.D. SEE LANDSCAPE DRAWINGS S.L.D.G. SINGLE LINE DIAGRAM S.M.D. SEE MECHANICAL DRAWINGS S.P.D. SEE PLUMBING DRAWINGS SLD SINGLE LINE DIAGRAM SPEC SPECIFICATION T TELEPHONE TYP TYPICAL TV TELEVISION UG UNDERGROUND UAC UNDER ANOTHER CONTRACT UON UNLESS OTHERWISE NOTED V VOLT VP VANDAL PROOF VS VACANCY SENSOR VSD VACANCY SENSOR WITH DIMMER W WATTS WAP WIRELESS ACCESS POINT WP WEATHERPROOF (NEMA 3R) WT WATERTIGHT XFMR TRANSFORMER 1. POWER SYSTEM: · F/I NEW RECEPTACLES IN SPACES PART OF SCOPE OF WORK. COORDINATE DEVICE FINISHES TO MATCH WITH OWNER APPROVED STANDARD. · PROVIDE POWER TO MECHANICAL EQUIPMENT. THIS INCLUDES HVAC SYSTEM. REFER TO MECHANICAL DRAWINGS AND NARRATIVES FOR REQUIREMENTS FOR CONNECTIONS TO EQUIPMENT. · PROVIDE POWER TO PLUMBING EQUIPMENT. THIS INCLUDES WATER HEATER SYSTEM. REFER TO PLUMBING DRAWINGS AND NARRATIVES FOR REQUIREMENTS FOR CONNECTIONS TO EQUIPMENT. 2. PV SYSTEM: (DESIGN/BUILD) · F/I CONDUIT TO ROOF. COORDINATE WITH PV DRAWINGS. · SYSTEM TO BE SUBMITTED UNDER SEPARATE PERMIT. · PV DESIGN BY OTHERS. · FURNISH AND INSTALL LOAD SIDE CONNECTED PV SYSTEM. SYSTEM SHALL BE MINIMUM OF 30kW DC. CONTRACTOR SHALL FURNISH COMPONENTS RELATED TO PV SYSTEM. INTERTIE SHALL BE AT 208V-3 PHASE. AC DISCONNECT SHALL BE PROVIDED BY CONTRACTOR. BASE BID PROJECT SHALL PROVIDE BREAKER IN MAIN SWITCH BOARD AND CONDUIT TO ROOF 3. LIGHTING SYSTEM: · F/I NEW INTERIOR LED LIGHTING FIXTURES AND T24 CONTROLS. · F/I NEW EXTERIOR LED LIGHTING FIXTURES AND T24 CONTROLS. · COORDINATE LIGHTING FIXTURE WITH ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHT AND EXACT LOCATIONS. · SEE TITLE 24 REQUIREMENTS. 4. FIRE ALARM SYSTEM: (DESIGN/BUILD) · DEFERRED PERMIT SUBMITTAL BY CONTRACTOR. · FIRE ALARM SYSTEM SHALL BE DESIGN/BUILD. SEE ADDITIONAL NOTES ON THIS PAGE. 5. LOW VOLTAGE SYSTEM: (DESIGN/BUILD) · F/I (N) CONDUIT WITH PULL STRINGS AND BOXES. · LOW VOLTAGE SYSTEMS SHALL BE DESIGN/BUILD. SEE ADDITIONAL NOTES ON THIS PAGE. 3a,bVSD XF EV EV SYSTEM APPROVAL THE CONTRACTOR IS RESPONSIBLE FOR SUBMITTING A COMPLETE SET OF MATERIALS TO THE LOCAL FIRE AND/OR BUILDING DEPARTMENT FOR DEFERRED APPROVAL. THIS SUBMITTAL IS TO INCLUDE ALL ITEMS LISTED IN THE SUBMITTALS SECTION. IN ADDITION, THE CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE POINT TO POINT, DEVICES, BATTERIES, ANY NECESSARY APPLICATIONS AND FEES. CONSULT WITH THE LOCAL AHJ FOR EXACT REQUIREMENTS. SYSTEM PERFORMANCE REQUIREMENTS 1. FURNISH AND INSTALL HORN-STROBES IN COMMON BUILDING AREAS, EXTERIOR, ACCESSIBLE ROOF DECKS, AND CORRIDORS. 2. FURNISH AND INSTALL SYSTEM SMOKE DETECTORS IN ALL EGRESS PATHWAYS INCLUDING BUT NOT LIMITED TO CORRIDORS, STAIRWELLS, AND ELEVATOR LOBBIES. 3. FURNISH AND INSTALL ASPIRATING SMOKE DETECTORS AT THE TOP OF ELEVATOR SHAFTS. 4. FURNISH AND INSTALL CONTROL AND MONITORING MODULES FOR ELEVATOR INTERFACE AND ELEVATOR RECALL. 5. FURNISH AND INSTALL MONITORING MODULES FOR TWO-WAY COMMUNICATION SYSTEM. 6. FURNISH AND INSTALL MONITORING MODULES FOR ERRCS IF REQUIRED FOR BUILDING. 7. FURNISH AND INSTALL MONITORING MODULES FOR FIRE SPRINKLER SYSTEM MONITORING INCLUDING STANDPIPES, AUTOMATIC SPRINKLER VALVES, PIV, BACK FLOW PREVENTERS, AND THE FIRE PUMP. 8. FURNISH AND INSTALL FIRE ALARM ANNUNCIATORS AS NOTED ON PLANS. 9. COORDINATE WITH OWNER FOR MONITORING SERVICE AND PHONE LINES. 10. CLOSELY COORDINATE WITH MECHANICAL FOR FIRE SMOKE DAMPERS AND DUCT DETECTORS FOR SHUTDOWN WHERE REQUIRED. 11. CLOSELY COORDINATE WITH ARCHITECTURAL FOR HOLD OPEN. 12. FURNISH AND INSTALL MONITORING MODULE FOR ROOF ELECTRICAL ROOM EXHAUST FAN. SUBMITTALS CONTRACTOR SHALL WITHIN TWO WEEKS OF NOTICE TO PROCEED SUBMIT THE FOLLOWING FOR THE ELECTRICAL ENGINEER'S REVIEW AND CONCURRENT APPROVAL BY THE AHJ. 1. PRODUCT DATA: PROVIDE DATA CUT SHEETS SHOWING ELECTRICAL CHARACTERISTICS AND CONNECTION REQUIREMENTS OF FIRE ALARM DEVICES. 2. PROVIDE CALIFORNIA STATE FIRE MARSHAL (CSFM) LISTING OF FIRE ALARM DEVICES. 3. INSTALLER NATIONAL INSTITUTE FOR CERTIFICATION IN ENGINEERING TECHNOLOGIES (NICET) LEVEL II CERTIFICATION. 4. SHOP DRAWINGS SHOWING THE FOLLOWING: A. DEVICE, CONDUITS, AND WIRING CONNECTION REQUIRED. B. INTERCONNECTION TO THE FIRE SPRINKLER SYSTEM VIA FLOW AND TAMPER SWITCHES. 5. MANUFACTURER'S INSTALLATION INSTRUCTIONS: INDICATE APPLICATION CONDITIONS AND LIMITATIONS OF USE STIPULATED BY PRODUCT TESTING AGENCY. INCLUDE INSTRUCTIONS FOR STORAGE, HANDLING, PROTECTION, EXAMINATION, PREPARATION, INSTALLATION AND STARTING OF PRODUCTS. TITLE 24 REQUIREMENTS PROJECT COMPLIES FROM THE FOLLOWING COMPLIANCE FORMS: 1. NRCC-ELC-E - ELECTRICAL POWER DISTRIBUTION · PROVIDED BY EDESIGNC, SEE SHEET TBD. 2. NRCC-LTI-E - INDOOR LIGHTING · PROVIDED BY EDESIGNC, SEE SHEET T24 SERIES. 3. NRCC-LTO-E - OUTDOOR LIGHTING · PROVIDED BY EDESIGNC, SEE SHEET T24 SERIES. CONTRACTOR TO FILL OUT AND SUBMIT THE FOLLOWING FORMS: 1. NRCA-LTI-02-A - LIGHTING CONTROLS 2. NRCA-LTI-03-A - AUTOMATIC DAYLIGHTING CONTROLS 3. NRCA-LTO-02-A - OUTDOOR MOTION SENSOR AND LIGHTING SHUT-OFF CONTROLS # D E-001 ELECTRICAL TITLE SHEET E-002 LIGHTING SCHEDULES E-003 POWER SCHEDULES E-201 LEVEL 01 - POWER PLAN E-203 ROOF - ELECTRICAL PLAN E-301 LEVEL 01 - LIGHTING PLAN E-401 ENLARGED ELECTRICAL ROOMS E-701 SINGLE LINE DIAGRAM E-702 ELECTRICAL LOAD CALCULATIONS E-801 ELECTRICAL DETAILS LOW VOLTAGE DESIGN/BUILD NOTES 1. COMMUNICATIONS SYSTEM · COORDINATE WITH AT&T AND COMCAST TO PROVIDE NEW MPOE WITH CONDUITS FROM THE NEAREST SERVICE CONNECTION POINT. · PROVIDE BUILD-OUT OF OWNER'S COMMUNICATIONS EQUIPMENT RACK INCLUDING CABLING, CABLE LADDER, VERTICAL AND HORIZONTAL ORGANIZERS, PATCH PANELS, POWER DISTRIBUTION UNITS (PDU), AND RELATED SUPPORTING EQUIPMENT. PROVIDE DATA, PHONE, WI-FI, AND CATV OUTLETS WITH HOMERUN WIRING TO EQUIPMENT RACK. 2. ACCESS CONTROL SYSTEM (ACS) · DESIGN, FURNISH, INSTALL COMPLETE ACCESS CONTROL SYSTEM INCLUDING INSTALLATION OF MAIN PANELS, SOFTWARE, SECURITY MANAGEMENT STATION, CARD READERS, AND WIRING. ALL WIRING SHALL BE IN CONDUIT. CARD READERS ARE REQUIRED AT MAIN BUILDING ENTRANCES, OFFICES, AND MEETING ROOMS. 3. VIDEO SURVEILLANCE SYSTEM (VSS) · DESIGN, FURNISH, INSTALL COMPLETE VSS INCLUDING NETWORK VIDEO RECORDER (NVR), POE SWITCHES, CABLING, AND CAMERAS. CABLING SHALL BE INSTALLED IN CONDUIT. NVR SHALL BE SIZED FOR 30 DAYS OF STORAGE. SITE COVERAGE SHALL INCLUDE PARKING, BUILDING PERIMETER, ENTRY/EXIT POINTS. COORDINATE WITH OWNER TO PROVIDE REMOTE OFF SITE CAMERA ACCESS. 4. INTRUSION DETECTION SYSTEM (IDS) · DESIGN, FURNISH, INSTALL COMPLETE INTRUSION DETECTION SYSTEM INCLUDING MAIN PANELS, SOFTWARE, MOTIONS SENSORS, DOOR SENSORS, ALARMS, AND WIRING. ALL WIRING SHALL BE IN CONDUIT. COORDINATE WITH OWNER TO PROVIDE REMOTE MONITORING. PROVIDE A SINGLE ZONE FOR THE WHOLE BUILDING WITH FULL COVERAGE OF ALL POTENTIAL BUILDING ACCESS POINTS. 5. VOICE/VIDEO INTERCOM SYSTEM · DESIGN, FURNISH, INSTALL COMPLETE VOICE & VIDEO INTERCOM SYSTEM INCLUDING MASTER, DOOR STATIONS, REMOTE DOOR UNLOCKING, POWER SUPPLIES, AND RELATED COMPONENTS.
PROJECT NUMBER: CLIENT: PHASE: SHEET TITLE: SHEET: All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer. REVISIONS: 2222 NE OREGON ST. SUITE 101 PORTLAND, OR 97232 PHONE: 503.702.2575 WWW.SALAZARCH.COM DRAWN BY: CHECKED BY: DATE CREATED: Salazar Architect, Inc. # DATE DESCRIPTION 2321 SHELTER II AT EAST BEAMER 1901 EAST BEAMER STREET WOODLAND, CA 95776 APN:027-360-042 THURMOND CONSULTING 2122 NATOMAS CROSSING SUITE 200-288 SACRAMENTO, CA 95834 75% CONSTRUCTION DOCUMENTS 10/02/24 E-002 EDC EDC LIGHTING SCHEDULES 1 SCALE: LIGHTING FIXTURE SCHEDULE 2 SCALE: NTS LIGHTING SEQUENCE OF OPERATION NTS
PROJECT NUMBER: CLIENT: PHASE: SHEET TITLE: SHEET: All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer. REVISIONS: 2222 NE OREGON ST. SUITE 101 PORTLAND, OR 97232 PHONE: 503.702.2575 WWW.SALAZARCH.COM DRAWN BY: CHECKED BY: DATE CREATED: Salazar Architect, Inc. # DATE DESCRIPTION 2321 SHELTER II AT EAST BEAMER 1901 EAST BEAMER STREET WOODLAND, CA 95776 APN:027-360-042 THURMOND CONSULTING 2122 NATOMAS CROSSING SUITE 200-288 SACRAMENTO, CA 95834 75% CONSTRUCTION DOCUMENTS 10/02/24 E-003 EDC EDC POWER SCHEDULES PANEL LA PANEL R1 PANEL L1 PANEL M1 PANEL R2 INV1 PANEL K1 PANEL R3 SCHEDULE SHEET LAYOUT MP EQUIP FEEDER SCHED KITCHEN FEEDER SCHED
20x20 20x20 20x20
20x20
20x20
20x20
3'-6"
60 24 x
60 24 x 60 24 x 60 24 x 36 24 x 48 21 X 48 21 X 54 24 x 54 24 x 48 24 x 48 24 x
42 24 x 42 24 x
42 24 x 42 24 x
42 24 x 42 24 x
54 24 x 60 21 / DS DSDSDS AC 1 DEGHF 2 5 12 B 113 SF NC-1 140 115 SF NC-2 139 115 SF NC-3 138 115 SF NC-4 137 115 SF NC-5 136 115 SF NC-6 135 115 SF NC-7 134 115 SF NC-8 133 115 SF NC-9 132 4 K 227 SF CASE MANAGEMENT 112 216 SF CASE MANAGEMENT 111 60 SF DATA 110 204 SF ADMINISTRATION OFFICE 109 143 SF INTAKE 102 122 SF PEST CONTROL 103 577 SF GROUP COUNSELING 124 105 SF STORAGE LINEN 115 121 SF UTILITY / STORAGE 117 425 SF LAUNDRY 114 650 SF MEN'S BATHROOM 118 131 SF CLIENT STORAGE 116 105 SF OFFICE 107 81 SF STAFF RESTROOM 108 410 SF WOMEN'S BATHROOM 148 131 SF ADMINISTRATION OFFICE 128 237 SF MEN'S BATHROOM-NC 147 238 SF WOMEN'S BATHROOM-NC 144 62 SF MEDICATION 127 104 SF COUNSELING OFFICE 1 143 80 SF MECHANICAL UTILITY 145 78 SF MAINTENANCE ROOM 146 87 SF LAUNDRY 129 104 SF COUNSELING OFFICE 2 142 6 7 8 9 10 11 440 SF DAY ROOM 141 102 SF WAITING AREA 125 921 SF COMMERCIAL KITCHEN 119 100 SF FIRE 122 100 SF ELECTRICAL 123 L 144 SF NC-11 154 144 SF NC-12 153 142 SF NC-13 152 142 SF NC-14 151 3 281 SF WAITING AREA 105 168 SF ENTRY 101 299 SF HALLWAY 5 106 126 SF HALLWAY 2 126 598 SF HALLWAY 3 130 914 SF HALLWAY 1 113 241 SF HALLWAY 4 149 116 SF NC-10 131 J 6.1 87 SF PANTRY 119E 174 SF REFRIGERATOR 119F 97 SF FREEZER 119G 57 SF RESTROOM 119C 53 SF OFFICE 119B 1 E-401 2 E-401 4 E-401 5 E-401 GFCI GFCI GFCI GFCI GFCI GFCI OS OS OS OS OS OS OS OS OS OS OS OS OS OSOS OS OSOS OS OS OS OS OS OS OS GFCI GFCI OS GFCI GFCI OS OS OS OS OS OS OSGFCI OS OS OS OS J T FCJ T HRV J DBFJ DBF JEF JEF JEF J T AC J TAC OS 3' AFF WP WP WP OS OS OS JFCT JFCT OS OS OS OS OS OS OS OS JHRVT JHRVT JFCT GFCI OS EWH GFCI WAP WAP WAP WAP WAP WAP WAP WAP WAP WAP CONDUIT RESERVED FOR PV STUB UP TO ROOF 3 E-401 1 (3) 5" CONDUITS TO UTILITY TRANSFORMER. COORDINATE WITH CIVIL DRAWINGS. JHRVT OS OS R1-7 R1-7 R1-7 R1-7 R1-9 R1-9 R1-9 R1-11 R1-11 R1-11 R1-11 R1-13 R1-13 R1-13R1-13 R1-15 R1-15 R1-15 R1-15 R1-17 R1-17 R1-17 R1-17 R1-19R1-19 R1-8 R1-8 R1-10 R1-10 R1-12 R1-14 R1-14 R1-16 R1-16 R1-16 R1-18 R1-18 R1-20 R1-20 R1-22 R1-5 R2-3 R2-3 R2-3 R2-3 R2-5 R2-5 R2-3 R2-2 R2-2 R1-21 R2-4 R2-4 R2-6 R2-6 R2-8 R2-8 R2-7 R2-7 R2-9 R2-7 R2-9 R2-9 R2-9 R2-11 R2-11 R2-11 R2-11 R2-13 R2-13 R2-13 R2-15 R2-15 R2-17 R2-17 R2-13 GFCI GFCI R2-10R2-12 R2-12 R2-14 R2-16,18 R2-20 R2-20 R2-20 R2-20 R2-19 R2-19 R2-19 R2-19 R2-21 R2-21 R2-21 R2-24 R2-22 R3-1 R3-1 R3-3 R3-3 R3-5 R3-7 R3-5 R3-7 R3-9 R3-9 R3-11 R3-11 R3-13 R3-15 R3-13 R3-15 R3-2 R3-2 R3-4 R3-4 R3-6R3-8 R3-6 R3-19 R3-8 R3-17 R3-19R3-17 R3-14 R3-14 R3-16 R3-16 R3-12 R3-10 R3-12R3-10 R3-20 R3-18 R3-20R3-18 2222 33 R2-23 M1-1,3 M1-5,7 M1-9,11 M1-2 M1-4,6 M1-8,10 M1-12,14 M1-33,35,37 PROJECT NUMBER: CLIENT: PHASE: SHEET TITLE: SHEET: All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer. REVISIONS: 2222 NE OREGON ST. SUITE 101 PORTLAND, OR 97232 PHONE: 503.702.2575 WWW.SALAZARCH.COM DRAWN BY: CHECKED BY: DATE CREATED: Salazar Architect, Inc. # DATE DESCRIPTION 2321 SHELTER II AT EAST BEAMER 1901 EAST BEAMER STREET WOODLAND, CA 95776 APN:027-360-042 THURMOND CONSULTING 2122 NATOMAS CROSSING SUITE 200-288 SACRAMENTO, CA 95834 75% CONSTRUCTION DOCUMENTS 10/02/24 E-201 EDC EDC LEVEL 01 - POWER PLAN 1 SCALE: LEVEL 01 - POWER PLAN 3/16" = 1'-0" N GENERAL NOTES A. ALL ITEMS LISTED OR SHOWN SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR, UON. B. PROVIDE POWER TO HVAC AND PLUMBING EQUIPMENT. F/I JUNCTION BOX MOUNTED ABOVE CEILING / FLUSH MOUNTED ON WALL AS SHOWN ON PLANS. FOR 1 PHASE LOADS, F/I LOCKABLE BREAKER. FOR 2 PHASE LOADS, F/I LOCAL HP RATED TOGGLE SWITCH. FOR 3 PHASE LOADS, F/I LOCAL DISCONNECT SWITCH. COORDINATE EXACT LOCATION, CONTROL, AND POWER REQUIREMENTS WITH MECHANICAL AND PLUMBING DRAWINGS. REFER TO SHEET E-003 FOR EQUIPMENT FEEDER SCHEDULE. C. PROVIDE POWER TO FOODSERVICE EQUIPMENT. COORDINATE EXACT LOCATION, CONTROL, AND POWER REQUIREMENTS WITH FOODSERVICE DRAWINGS. REFER TO SHEET E-003 FOR KITCHEN EQUIPMENT SCHEDULE. D. PROVIDE POWER TO THERMOSTATS. COORDINATE POWER REQUIREMENTS WITH MANUFACTURER. COORDINATE EXACT LOCATION AND MOUNTING HEIGHT WITH MECHANICAL DRAWINGS. E. FOR PLUG LOAD CONTROLLED RECEPTACLES: · QUAD RECEPTACLE - F/I SPLIT DUPLEX RECEPTACLE WITH ONE CONTROLLED AND ONE UNCONTROLLED RECEPTACLE PER CEC 130.5(D). · DUPLEX RECEPTACLE - CONTROLLED RECEPTACLE. SHEET NOTES 1. 1/2" CONDUIT MOUNTED ABOVE CEILING RESERVED FOR TELECOM. 2. NEW OUTLETS IN THIS ROOM SHALL BE FED FROM NEAREST AVAILABLE ELECTRICAL PANEL OF EXISTING BUILDING. PROVIDE TWO (2) 20A/1P CIRCUITS TO EACH NC ROOM. CONTRACTOR TO VERIFY IN FIELD. 3. NEW MECHANICAL EQUIPMENT SHALL BE FED FROM NEAREST AVAILABLE ELECTRICAL PANEL OF EXISTING BUILDING. CONTRACTOR TO VERIFY IN FIELD. #
AC 1 DEGHF 2 5 12 B 44 K 6 7 8 9 10 11 L 3 J 6.1
1 1/2" / 1'-0"
1/4" / 1'-0"
1/4" / 1'-0" 1/4" / 1'-0" 1/4" / 1'-0" 7.6 7.6 7.6 7.6 CU CU HP CU CU WP WP WP HWC WH CU WP FC EF WP WH CONDUIT RESERVED FOR PV STUB DOWN TO ELECTRICAL ROOM BELOW HP HP MAU ELECTRICAL ROOM BELOW 1 EXISTING BUILDING ROOF (N.I.C) REMODEL OF EXISTING OFFICES REMODEL OF EXISTING OFFICES EXISTING BUILDING ROOF (N.I.C) M1-1,3 M1-13,15,17 M1-5,7 M1-18,20 M1-20,22 M1-19,21 M1-23,25 M1-19,21 M1-27,29,31 M1-23,25 R2-25 R2-25 R2-27 R1-23 2 3 K1-29,31,33 STEP UP XFMR FEEDING WH-1 AND WH-2 208V, 3PH TO 480V, 3PH MODEL: LOCHINVAR PART #100371007 COORDINATE EXACT LOCATION WITH PLUMBING DRAWINGS AND INSTALLATION WITH STRUCTURAL DRAWINGS. 20A/3P, 480V HEAVY DUTY DISCONNECT FOR XFMR SECONDARY SIDE. F/I 3/4"C - 3#10 + #10GND M1-34,36,38 50A/3P, 208V HEAVY DUTY DISCONNECT FOR XFMR PRIMARY SIDE. F/I 3/4"C - 3#6 + #10GND 20A/3P, 480V HEAVY DUTY DISCONNECT FOR WATER HEATER. 20A/3P, 480V HEAVY DUTY DISCONNECT FOR WATER HEATER. M1-40 PROJECT NUMBER: CLIENT: PHASE: SHEET TITLE: SHEET: All drawings and written materials apperaing herein constitute the original and unpublised work of the designer and the same may not be duplicated, used, or disclosed without the written consent of the designer. REVISIONS: 2222 NE OREGON ST. SUITE 101 PORTLAND, OR 97232 PHONE: 503.702.2575 WWW.SALAZARCH.COM DRAWN BY: CHECKED BY: DATE CREATED: Salazar Architect, Inc. # DATE DESCRIPTION 2321 SHELTER II AT EAST BEAMER 1901 EAST BEAMER STREET WOODLAND, CA 95776 APN:027-360-042 THURMOND CONSULTING 2122 NATOMAS CROSSING SUITE 200-288 SACRAMENTO, CA 95834 75% CONSTRUCTION DOCUMENTS 10/02/24 E-203 EDC EDC ROOF - ELECTRICAL PLAN 1 SCALE: ROOF - ELECTRICAL PLAN 3/16" = 1'-0" N GENERAL NOTES A. ALL ITEMS LISTED OR SHOWN SHALL BE FURNISHED AND INSTALLED BY CONTRACTOR, UON. B. PROVIDE POWER TO HVAC EQUIPMENT. F/I LOCAL DISCONNECT SWITCH AS SHOWN ON PLANS. COORDINATE EXACT LOCATION, CONTROL, AND POWER REQUIREMENTS WITH MECHANICAL DRAWINGS. REFER TO EQUIPMENT FEEDER SCHEDULE ON SHEET E-003. C. PROVIDE POWER TO FOODSERVICE EQUIPMENT. COORDINATE EXACT LOCATION, CONTROL, AND POWER REQUIREMENTS WITH FOODSERVICE DRAWINGS. REFER TO KITCHEN EQUIPMENT SCHEDULE ON SHEET E-003. D. AIR CONDITIONING EQUIPMENT MUST BE INSTALLED TO THE EQUIPMENT MINIMUM CIRCUIT AMPACITY (MCA) AND MAXIMUM OVERCURRENT PROTECTION (MOCP) AS SEEN ON THE NAMEPLATE. E. GFCI (WP) PROTECTED SERVICE RECEPTACLES WITH EXTRA DUTY COVERS MUST BE INSTALLED WITHIN 25 FEET OF EQUIPMENT PER CEC 210.63 AND CMC 301.4. SEE DETAIL: F. DISCONNECT SWITCHES WITH OVERCURRENT PROTECTION SHALL HAVE WORKING CLEARANCE PER NEC 110.26. SEE DETAIL: SHEET NOTES 1. REMOTE REFRIGERATION. PROVIDE 208V/3P POWER. COORDINATE EXACT LOCATION AND MOUNTING WITH FOODSERVICE DRAWINGS. 2. NEW MECHANICAL EQUIPMENT SHALL BE FED FROM NEAREST AVAILABLE ELECTRICAL PANEL OF EXISTING BUILDING. CONTRACTOR TO VERIFY IN FIELD. 3. NEW CONVENIENCE HEAVY DUTY OUTLET SHALL BE FED FROM NEAREST AVAILABLE ELECTRICAL PANEL OF EXISTING BUILDING. CONTRACTOR TO VERIFY IN FIELD. # 8 E-801 6 E-801