METAL DECK WITH
INTERCORP/STRONG
POINT #12 HEX HEAD
SCREWS @ 12" O.C.
CONT. BENT CLOSURE
PLATE PER PEMB
DRAWINGS.
CURB. REFER
TO VIEW 'A'
ROOF AND ROOF
STRUCTURE PER
PEMB DRAWINGS.
ROOF ACCESS LADDER
RETRACTABLE SAFETY POST
LOCK STRICK & PADLOCK HASP
FRAME W/ CAP FLASHING
SHT. METAL CURB.
PREFINISHED TO
MATCH ROOF PANELS.
REFER TO VIEW "A"
SHT. METAL CRICKET
IN CURB, PREFINISHED
TO MATCH ROOF
PANELS. REFER TO
VIEW "A"
STRUCTURAL FRAMING
AROUND OPENING. REFER TO
PEMB DRAWINGS.5'-0" MAX"M WASHER"
SUPPORT PLATE
4'-0"
TYPICAL SECTION PERPENDICULAR TO SEAMSTYPICAL SECTION PARALLEL TO SEAMS
SELF-DRILLING FASTENER
STANDING SEAM
CLAMP (S-5 B.O.D.)
SELF-DRILLING FASTENER
PLANK
SUPPORT PLATE
M WASHER
PLANK
CENTERLINE OF
SEAM OF STANDING
SEAM METAL ROOF
TYPICAL PLAN
SEAM OF STANDING
SEAM METAL ROOF
U.N.O.
EQ2'-0" MIN.
U.N.O.
EQ
NOTE:
ALL ROOF WALKWAY SYSTEM COMPONENTS
SHOWN ARE FOR REFERENCE ONLY TO
DEMONSTRATE MINIMUM CODE
REQUIREMENTS AND GENERAL DESIGN
INTENT. THE FINAL DESIGN AND ANALYSIS
SHALL BE SUBMITTED TO THE CITY AS A
DEFERRED SUBMITTAL. CITY APPROVAL IS
REQUIRED PRIOR TO FABRICATION AND
INSTALLATION.
•
•
•
•
•
SYSTEM BASIS OF DESIGN IS R&S
MANUFACTURING AND SALES RW24-SS-40-P
(WHITE) ROOF WALKWAYS.
(DEFERRED APPROVAL)
INSTALLATION NOTES:
ATTACHED PLANKS ON SUPPORT PLATES
USING 3" SELF-DRILLING SCREWS AND "M"
WASHERS
GRATINGS SHOULD BE BUTTED END TO
END OVER SUPPORTS AND SPLICE PLATES.
INSTALL S-5 BLOCKS OVER SEAMS.
CONSULT ROOF MANUFACTURER FOR
SPECIFIC INSTRUCTIONS AND WARRANTY
INFORMATION.
ROOFWALK PLANS AND SUPPORTS
WEIGHT APPROXIMATELY 13 LBS/FT.
ROOF ACCESS
PLATFORM
PER MFR.
ROOF ACCESS LADDER.
WALL PER PLAN.
GUARDRAIL
PER MFR.CLEAR6" MIN.CLEAR6" MIN.4'-0"INTERIOR FACE OF WALL WHERE OCCURS PER PLAN.
WHERE WALL DOES NOT OCCUR:
EXTERIOR FACE OF GUARDRAIL.
WALL WHERE
OCCURS PER PLAN.
2'-6" CLEAR
3'-4"
STEEL BAR CAGE.
SEE 09/A8.22
02 - FLOOR
15'-0"
E02
A7.21 D.9
ROOF ACCESS LADDER
PER MFR
ROOF ACCESS
PLATFORM PER MFR
GUARDRAIL PER MFR
ROOF ACCESS LADDER
WITH CAGE ABOVE
ROOF HATCH
FIXED RAILING SYSTEM
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.95% CONSTRUCTION DOCS 08/01/2025
As indicatedCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ROOF ACCESS
DETAILS
A8.22
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 1/4" = 1'-0"01ROOF ACCESS ELEVATION - NORTH
3/4" = 1'-0"09CAGE LADDER ELEVATION 1 1/2" = 1'-0"13ROOF ACCESS LADDER 1 1/2" = 1'-0"14ROOF ACCESS LADDER - UPPER
1 1/2" = 1'-0"21ROOF ACCESS LADDER PLAN -
INTERIOR
1 1/2" = 1'-0"03ROOF HATCH CURB 1" = 1'-0"15BATTEN METAL ROOF WALKWAY 1" = 1'-0"22ROOF ACCESS LADDER PLAN AT
PLATFORM LEVEL- INTERIOR
1/4" = 1'-0"05ROOF ACCESS ELEVATION - WEST
CONCRETE CURB
SEE LANDSCAPE DWG
FOR GROUND OR
PAVING CONDITION
0' - 0"
01 - FIRST FLOOR
6" MIN AT LANDSCAPE2" MIN AT PAVING0'-6"W2
BACKER ROD AND
SEALANT
BLOCKING AS REQ
5/8" TYPE "X" GYP BD
EXTERIORINTERIOR
TYP0'-2"CONCRETE CURB
SEE LANDSCAPE DWG
FOR GROUND OR
PAVING CONDITION
0' - 0"
01 - FIRST FLOOR
INTERIOR EXTERIOR
W1
6" MIN AT LANDSCAPE2" MIN AT PAVING5/8" TYPE "X" GYP BD,
WHERE OCCURS
0'-6"TYP0'-2"INTERIOR
EXTERIOR
SASM, HIGH TEMP,
TYP
W2 3/8" REVEAL
BLOCKING AS REQ
5/8" TYPE "X" GYP BD
SHEAR WALL PER
STRUCTURAL DWGS
SHEET METAL
CORNER WRAP
FIELD MITER
PANELS
HSS COLUMN
PER PEMB MFR
HSS COLUMN PER PEMB MFR
INTERIOREXTERIOR
EXTERIOR
GRID
GRID
W1
FILL VOIDS WITH
COMPRESSIBLE FOAM CLOSURE
RUBBER JOINT GASKET
FILL VOIDS WITH COMPRESSIBLE
FOAM CLOSURE
RUBBER JOINT GASKETREVEAL
0'-0 1/2"W1INTERIOR
EXTERIOR
STEEL COLUMN PER PEMB MFR
GRID
GRID
BACKER ROD AND SEALANT.
DEPTH OF SEALANT TO
MATCH REVEAL DEPTH.
COMPRESSIBLE
FOAM CLOSURE
CORNER TRIM
W1
GRID GRID
GRID
EXTERIORINTERIOR R1AW1
METAL PANEL CEILING
PER SPECS
INTERIOR CEILING
ASSEMBLY
COMPRESSIBLE FOAM
TRAPAZOIDAL STANDING SEAM ROOFR1B
BRACING PER PEMB
STRUCTURE WHERE
OCCURS
INTERIOREXTERIOR
GRID
SLOPE
R1AW1
METAL PANEL
CEILING PER SPECS
INTERIOR CEILING
ASSEMBLY
COMPRESSIBLE
FOAM
TRAPAZOIDAL STANDING
SEAM ROOF
R1BINTERIOREXTERIOR
GRIDR2A
SLOPE
W2R2B12
METAL PANEL CEILING
PER SPECS
LINE OF SUSPENDED CEILING
AND INTERIOR WALL FINISH
OCCURS BELOW
SHEAR WALL PER STRUCTURAL DWGS
INTERIOREXTERIOR
W2
SHEET METAL CORNER WRAP
5/8" TYPE "X" GYP BD
BLOCKING AS REQ
SASM, HIGH TEMP, TYP
FIELD MITER PANELS
HSS COLUMN
PER PEMB MFR
W1
5/8" TYPE "X" GYP BD,
WHERE OCCURS
GRID
3/8" REVEALSTRUCTURE PER PEMB
MANUFACTURER
INSULATED METAL PANEL
PER PEMB MANUFACTURER
INTERIOR EXTERIOR
FILL VOIDS WITH COMPRESSIBLE
FOAM CLOSURE
RUBBER JOINT GASKETREVEAL
0'-0 1/2"W1INTERIOR
EXTERIOR
STEEL COLUMN PER
PEMB MFR
GRID
GRID
INSULATED METAL
PANEL PER MFR
STEEL BEAM PER
PEMB MFR
FASTENER PER MFR
2 PIECE FLASHING WITH
1/2" HEMMED EDGE
SEALANT
FILL VOID WITH FIP
INSULATION
SECTIONELEVATION
STEEL BEAM
PENETRATION
2 PIECE FLASHING
WITH 1/2" HEMMED
EDGE
FASTENER PER MFR
SILICONE SEALANT
AROUND PENETRATION
LINE OF CEILING
SILICONE SEALANT
AT PANEL JOINTS
INSULATED METAL
PANEL JOINT
STEEL BEAM PER
PEMB MFR
STRUCTURE PER
PEMB MFR
EXTERIORINTERIOR
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202230% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 3" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
INSULATED METAL
PANEL DETAILS
A8.31
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 3" = 1'-0"01STEM INSULATED METAL PANEL CURB - W2
3" = 1'-0"02EXHIBIT HALL INSULATED METAL
PANEL CURB - W1
3" = 1'-0"
A8.31 07STEM IMP CORNER - W2
3" = 1'-0"
A8.3117ANGLED WALL PLAN 3" = 1'-0"13COLUMN AT IMP OUTSET GIRT - TYP
3" = 1'-0"
A8.31 05EXHIBIT HALL INSULATED METAL PANEL CORNER - W1
3" = 1'-0"04EXHIBIT BUILDING EXTERIOR WALL TO ROOF CANOPY 3" = 1'-0" A8.31 12EXTERIOR WALL TO ROOF CANOPY PERPENDICULAR 3" = 1'-0" A8.3120EXTERIOR WALL TO CANOPY STEM
3" = 1'-0"
A8.31 06STEM IMP CORNER - W2
3" = 1'-0"
A8.31 03HORIZONTAL JOINT DETAIL
3" = 1'-0"14COLUMN AT IMP INSET GIRT - TYP
3" = 1'-0"11BEAM PENETRATION DETAIL
ALIGNSTEEL PLATE WELDED TO
TUBE STEEL BEAM
TUBE STEEL BEAM PER PRE
ENGINEERED METAL
BUILDING MFR
W1
22 GA SHEET METAL DRIP WITH
1/2" HEMMED EDGE, PREFINISHED
TO MATCH ADJACENT FRAME, TYP
GA1
EXTERIOR INTERIOR
SASM, HIGH TEMP, TYP
SECTION AT
CONNECTION
1"
INTERMEDIATE
SECTION
TUBE STEEL COLUMN
BEYOND
VERTICAL CURTAIN WALL
MULLION BEYOND
STEEL PLATE WELDED TO
TUBE STEEL BEAM
PROVIDED BY PRE
ENGINEERED METAL
BUILDING MFR
TUBE STEEL BEAM PER
PRE ENGINEERED
METAL BUILDING MFR
GA1W1
INTERIOR
EXTERIOR
wewrwerGA1
HARDSCAPE PER
LANDSCAPE
CAULKING
EXPANSION
MATERIAL AND
SEALANT
STRUCTURAL SLAB
0'-0 3/8"
GA1
0' - 0"
01 FLOOR
CURTAIN WALL MULLION BEYOND
1'-6"
CORNER CURTAIN WALL MULLION
CURTAIN WALL MULLION
HSS TUBE STEEL COLUMN PER PRE
ENGINEERED METAL BUILDING MFR
SEALANT AND BACKER ROD
1" INSULATED GLASS
1'-6"GA1
INTERIOR
EXTERIOR
GA1
W1
0'-1"
HSS TUBE STEEL COLUMN PER PRE
ENGINEERED METAL BUILDING MFR
ALIG
N
INTERIOREXTERIOR
SASM, HIGH TEMP, TYP
1" INSULATED LOW-E GLASS
VERTICAL CURTAIN
WALL MULLION
CURTAIN WALL MULLION BEYOND
1"CURTAIN WALL MULLION
BEYOND
TUBE STEEL
COLUMN BY PRE
ENGINEERED METAL
BUILDING
MANUFACTURER
PLAN DETAILGA1 NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202230% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 3" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
CURTAIN WALL
SYSTEM DETAILS
A8.32
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 3" = 1'-0"04CURTAINWALL HEADER AT IMP 3" = 1'-0"
A8.32 02TYP CURTAINWALL MULLION AT GIRT
3" = 1'-0"
A8.32 07CURTAINWALL JAMB AT IMP
3" = 1'-0"
A8.32 01TYP CURTAIN WALL AT SLAB
3" = 1'-0"
A8.32 12CURTAIN WALL OBLIQUE CORNER DETAIL
3" = 1'-0"
A8.32 10CURTAINWALL AT PARTIAL WALL 3" = 1'-0"
A8.32 06VERTICAL MULLION AT COLUMN
8 AW1INTERIOR
EXTERIOR
BLOCKING
PARTITION TYPE PER PLAN
STEEL COLUMN PER PEMB MFR
E
D.9
EXTERIOR
INTERIORW1
02 - FLOOR
15'-0"
9 GRID
W1
INTERIOR EXTERIOR
PREF-FINISHED
ALUMINUM COVER
PLATE PER MFR
EXPANSION ANCHOR
CONCRETE METAL
DECK PER PEMB MFR
REINFORCED VAPOR
BARRIER
CONTINUOUS SEALANT
FINISH FLOOR
PER PLAN
GRID
HSS COLUMN PER
PEMB MFR
PARTITION TYPES
PER PLAN
9 GRID
INTERIOR EXTERIOR
W1
02 - FLOOR
15'-0"
9 W1
INTERIOR EXTERIOR
MECHANICAL DUCT PER
MECHANICAL DWGS
COMPRESSIBLE FOAM
CLOSURE
BATT INSULATION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.30% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 3" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
WALL SYSTEMS
DETAILS
A8.33
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 3" = 1'-0"01RATED & NON-RATED EXTERIOR WALL - TYP - PLAN 3" = 1'-0"02RATED WALL TO EXTERIOR DOOR - PLAN
3" = 1'-0"09SECOND FLOOR AND INSULATED METAL PANEL WALL CONNECTION- W1 3" = 1'-0"03TYP INTERIOR RATED VS
NON-RATED INTERSECTION - PLAN
3" = 1'-0"20MECHANICAL SHAFT 3" = 1'-0"12MECHANICAL SHAFT AT EXTERIOR WALL - W1 3" = 1'-0"11MECHANICAL SHAFT AT EXTERIOR WALL - W1
OPERABLE GLASS WALL
WITH INSULATED GLASS
0'-1 3/8"0'-4"
PEMB BEYOND
SLOPE 2% MAX.
HARDSCAPE PER
LANDSCAPE DWGS
CAULKING
COMPRESSIBLE FILLER
STRUCTURAL SLAB
INTERIOR EXTERIOR
W1
INTERIOREXTERIOR
STRUCTURE PER
PEMB MANUFACTURER
MECHANICAL LOUVER
PER MECHANICAL
DRAWINGS
PEMB BEYOND
SASM, HIGH TEMP,
TYP
0'-2 1/2"
MECHANICAL LOUVER
PER MECHANICAL
DRAWINGS
EXTERIORINTERIOR
W1
STRUCTURE PER PEMB
MANUFACTURER
0'-1 1/2"
0'-2 1/2"
PEMB BEYOND
FIXED EXTRUDED DRAINABLE
LOUVER (INVISIBLE MULLION);
INDUSTRIAL LOUVER
INTERIOR
EXTERIOR
PEMB BEYONDW1FRAMING PER PEMB
MANUFACTURER
BACKER ROD
AND SEALANT
INTERIOR EXTERIOR
W2
22 GA SHEET METAL DRIP
WITH 1/2" HEMMED EDGE,
PREFINISHED TO MATCH
ADJACENT TRIM, TYP
DOOR PER SCHEDULE,
TYP
HSS PER STRUCTURAL
DWGS
BLOCKING AS REQ
0'-4"
0'-2 1/2"
INTERIOR
EXTERIOR
W25/8" TYPE "X" GYP BD,
WHERE OCCURS
SHIM AS REQALIGN
DOOR PER SCHEDULE, TYP
LINE OF JAMB BEYOND
DOOR AND HARDWARE PER SCHEDULE
ALUMINUM THRESHOLD PER
SCHEDULE; BEDDED IN SEALANT
TO ST/STL EDGE FLASHING
2 1/2" x 1 1/2" x DOOR WIDTH 24
GA ST/STL FLASHING BEDDED
IN SEALANT TO EDGE OF SLAB
TYP AT ALL DOOR
THRESHOLDS
HARDSCAPE PER LANDSCAPE
CAULKING
COMPRESSIBLE FILLER
STRUCTURAL SLAB
FINISH PER FINISH PLAN
EXTERIORINTERIOR
SLOPE 2% MAX.1/2" MAX1/2" MAX...1/4"1
2 1/2" MAXALIGNW1
INTERIOR EXTERIOR
0'-2 1/2"
STRUCTURE PER
PEMB
MANUFACTURER
DOOR PER
SCHEDULE, TYP
PEMB BEYOND
0'-1 1/2"
22 GA SHEET METAL
DRIP WITH 1/2"
HEMMED EDGE,
PREFINISHED TO
MATCH ADJACENT
TRIM, TYP
SASM, HIGH TEMP,
TYP
5/8" TYPE "X" GYP BD,
WHERE OCCURS
METAL CORNER
FLASHING
STRUCTURE PER
PEMB
MANUFACTURER
W1
INTERIOREXTERIOR
0'-2 1/2"
PEMB BEYOND
0'-1 1/2"
22 GA SHEET METAL
DRIP WITH 1/2"
HEMMED EDGE,
PREFINISHED TO
MATCH ADJACENT
TRIM, TYP
5/8" TYPE "X" GYP BD,
WHERE OCCURS
0'-2 1/2"0'-1"
INTERIOREXTERIOR
OPENING PER
ELEVATIONS
W1
PEMB BEYOND
STRUCTURE PER
PEMB
MANUFACTURER
0'-2 1/2"
SASM, HIGH TEMP,
TYP
5/8" TYPE "X" GYP
BD, WHERE
OCCURS
0'-2 1/2"0'-1"W1EXTERIOR
INTERIOR
PEMB BEYOND
SILL BEYOND
5/8" TYPE "X" GYP BD, WHERE
OCCURS
FRAMING PER PEMB
MANUFACTURER
INTERIOR
EXTERIOR
W15/8" TYPE "X" GYP BD, WHERE
OCCURS
FRAMING PER PEMB MANUFACTURER
ANCHOR PER 04/--
HM DOOR FRAME
INTERIOR
EXTERIOR
DOOR PER SCHEDULE, TYP
DOOR FRAME TO MATCH
FRAMING SYSTEM GA1INTERIOR EXTERIOR
DOOR FRAME TO MATCH
FRAMING SYSTEM
GA1
DOOR PER SCHEDULE,
TYP
STRUCTURE PER PEMB
MANUFACTURER
CURTAIN WALL BEYOND
STUD CAPFLOOR CLIPBOLT-IN-Z
TYP MULLION &
HEAD WELD
ABC
D
5 1/2"
1"
ANCHOR CLIP (16-GA)
W/ (2) #10 SHEET MTL
SCREWS AT EACH
LEG
5"1 1/2"2 1/4"
EMBEDMENT
OF 1/2" HILTI
KB-TZ PER ICC
ESR-1917 W/ 3"
MIN EDGE
DISTANCE 16 GA 'L'
5"
ANCHOR SPACING PER SPECS
SEE JAMB DETAILS FOR STUD
SIZES OVERLAP HM FRAME &
GYP BD, 1/2" MIN
3 ANCHORS PER JAMB AND 2 AT HEAD,
NOT TO EXCEED 24" OC PUNCH AND
DIMPLE FOR 3/8" BOLTS AND PROVIDE
'Z' SPACERS AT EACH BOLTS, SHIELDS,
SHIMS, ETC
NOTE: FOR ADD INSTALLATION
INFO, SEE SPECIFICATIONS
16 GA 'Z'
(1"x1 1/4"x1")
3/8" DIA HILTI KB-3
PER ICC ESR-1385
1. 2.
3. 4.
5. 6.
NOTES:
ALL HOLLOW MTL FRAME/JAMBS SHALL BE CUT FOR
STANDARD UNIT LOCK STRIKES 3/4" HIGH.
FRAME DIMENSIONS ARE FROM FINISH PAVING. FRAME
DIMENSIONS MAY VARY DUE TO FINISH MATERIALS.
SEE 'LABELS' ON DOOR SCHEDULE FOR REQ RATED
DOORS.
VERIFY ALL DOOR AND FRAME OPENING SIZES AND
WALL AND DOOR FRAME WIDTHS ON SITE.
PER CBC 715.4, APPROVED FIRE DOOR HDWR AND FIRE
DOOR FRAMES INCL THE ANCHORAGE THEREOF SHALL
BE INSTALLED IN ACCORDANCE WITH THEIR LISTING.
ADHERE TO UBC STANDARD 7-2 FOR INSTALLATION OF
DOOR FRAMES.
3" MIN
ADJ HAT SECTION (2) SPOT
WELDS PER END
NOTE: GROUT FRAME SOLID &
PROVIDE (3) ANCHOR STRAPS
PER JAMB.
ANCHOR AT CMU
& CONCRETE E
1/16TYP1/163 SIDES
1/16
1/163 SIDES
1/2" EXPANSION JOINT
THRESHOLD SET IN FULL
BED OF SEALANT
10"SLOPE
TOPPING SLAB PER
LANDSCAPE DRAWINGS
01 - FIRST FLOOR
0' - 0"
INTERIOR EXTERIOR
ALUMINUM DOOR WITH
TEMPERED 3/8" LAMINATED
GLASS
3" MIN
BACKER ROD AND SEALANT
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202230% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 As indicatedCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
OPENING DETAILS
A8.51
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 3" = 1'-0"05FOLDING WALL THRESHOLD 3" = 1'-0"17MECHANICAL LOUVER SILL - W1 3" = 1'-0"18MECHANICAL LOUVER HEADER -
W1
3" = 1'-0"19MECHANICAL LOUVER JAMB - W1
3" = 1'-0"06STEM BIFOLD DOOR HEADER - W2
3" = 1'-0"07STEM BIFOLD DOOR JAMB - SWING
- W2
3" = 1'-0"09EXTERIOR SILL DETAIL
3" = 1'-0"10EXHIBIT HALL DOOR HEADER - W1 3" = 1'-0"14STOREFRONT HEADER - W1 3" = 1'-0"13STOREFRONT SILL - W1
3" = 1'-0"15STOREFRONT JAMB - W1 3" = 1'-0"11EXHIBIT HALL DOOR JAMB - W1 3" = 1'-0"03ALUMINIUM DOOR JAMB - GA1 3" = 1'-0"02ALUMINIUM DOOR HEADER - GA1
12" = 1'-0"04TYPICAL HOLLOW METAL DOOR FRAME DETAILS
3" = 1'-0"01ALUMINUM EXT. DOOR
THRESHOLD
DOOR TRACK PER
SCHEDULE
SLAB DEPRESSION
EDGE OF SLAB
INSULATED METAL
PANEL BY PEMB
MANUFACTURER
BEYOND
OVERHEAD DOOR PER
SCHEDULE
0'-1 1/2"THRESHOLD
01 - FLOOR
CIVIL DRAWINGS
ELEVATION PER
1" / 20" MAX.
CHAIN
CLEARANCE FOR
PULLEY ABOVE
CARRIAGE ABOVEW1
TRACK PER DOOR
MANUFACTURER
STEEL TRACK
SUPPORTS PER
MANUFACTURER
RECOMMENDATIONS
DOOR PER SCHEDULE
HSS COLUMN BEYOND PER PEMB
MANUFACTURER
VERTICAL TRACK PER MANUFACTURER
HEAD PLATE
ADJUSTABLE BRACKET, TYP
STRUCTURE WITH HIGH PERFORMANCE
EXTERIOR FINISH PER PEMB
MANUFACTURER
DOOR PER SCHEDULE, TYP
JAMB BRACKETS PER MANUFACTURER
INTERIOREXTERIOR
SHEET METAL,
COLOR TO MATCH
COMPOSITE METAL
PANEL
BREAKAWAY
TRACK PER
MANUFACTURER
CABLE DRUM
GA1
STRUCTURE WITH
HIGH PERFORMANCE
EXTERIOR FINISH BY
PEMB
MANUFACTURER
STRUCTURE BY PEMB
MANUFACTURER
ABOVE
SHEET METAL,
COLOR TO MATCH
COMPOSITE METAL
PANEL
VERTICAL TRACK PER
MANUFACTURER
DOOR PER
SCHEDULE, TYP GA1STEEL TRACK
SUPPORTS PER
MANUFACTURER
RECOMMENDATIONS
1'-10"0'-3"1'-9"
W1
DOOR MOTOR REQUIREMENTS
PER MANUFACTURER
OVERHEAD DOOR
PER SCHEDULE
COILING DOOR COVER. PAINT
TO MATCH ADJACENT WALL
SHEET METAL,
COLOR TO MATCH
ADJACENT PANEL
FINISH
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202230% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 3" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
OPENING DETAILS
A8.52
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 3" = 1'-0"09ROLLUP DOOR THRESHOLD TYP 3" = 1'-0"12STORAGE ROOM ROLLUP DOOR
JAMB
3" = 1'-0"01GLAZED OVERHEAD DOOR
3" = 1'-0"04GLAZED VERTICAL DOOR JAMB
3" = 1'-0"10OVERHEAD COILING DOOR HEADER
10 EXTERIOR
STRUCTURE WITH HIGH
PERFORMANCE EXTERIOR FINISH
BY PEMB MANUFACTURER
PULLEY BEYOND PER DOOR
MANUFACTURER
COUNTERWEIGHT AND TRACK
BEYOND PER DOOR
MANUFACTURER
MOTOR ROD PER DOOR
MANUFACTURER
INTERIOR
DOOR PER SCHEDULE
0'-1"
SHEET METAL, COLOR TO MATCH COMPOSITE
METAL PANEL AT JAMB
EXTERIOR CURTAIN WALL
PER ELEVATIONS
COMPOSITE METAL PANEL, TYP.
DOOR STEEL BRACING PER
MANUFACTURER
10 STRUCTURE WITH HIGH
PERFORMANCE
EXTERIOR FINISH BY
PEMB MANUFACTURER
COMPOSITE METAL
PANEL, TYP.
EXTERIOR
BACKER ROD AND
SEALANT AT SILL
DOOR COUNTERWEIGHT
PULLEY BY MANUFACTURER
MOUNTING PLATE
FASTENED TO STEEL
STRUCTURE
FLUSH MOUNT SAFETY
SENSOR BY MANUFACTURER
INTERIOR
BACKER ROD AND SEALANT
SURFACE MOUNTED
FIRE EXTINGUISHER
CABINET
4" MAX
GL
0'-1"
DOOR PER SCHEDULE
WATERPROOFING MEMBRANE
EXTERIOR CURTAIN
WALL PER ELEVATIONS
ALIGN0'-1"ALIGNSHEET METAL, COLOR TO
MATCH COMPOSITE METAL
PANEL
MOTOR BY
MANUFACTURER
MOTOR CONTROLLER
BY MANUFACTURER
2'-0"1'-8 1/4"
SLOPE 2%
EXTERIOR
GL
INTERIOR
SAFETY SENSOR BY
DOOR MANUFACTURER
COMPOSITE METAL
PANEL, TYP.
SHEET METAL, COLOR TO
MATCH COMPOSITE METAL
PANEL
STRUCTURAL SLAB
ALUMINUM THRESHOLD BY
DOOR MANUFACTURER
DOOR STEEL BRACING
PER MANUFACTURER
DOOR PER SCHEDULE
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202230% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 3" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
OPENING DETAILS
A8.53
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 3" = 1'-0" A8.5315HANGAR DOOR HEAD
3" = 1'-0"
A8.53 01HANGAR DOOR PLAN DETAIL 3" = 1'-0"
A8.5313HANGAR DOOR THRESHOLD
BOTTOM OF STRUCTURE
CEILING SYSTEM, WHERE
OCCURS SEE REFLECTED
CEILING PLAN
(1) LAYER OF 5/8" TYPE "X"
GYP BD BOTH SIDES, UNO,
SEE FINISH PLANS AND
ELEVATIONS
METAL STUD FRAMING PER
NOTES
ACOUSTICAL INSULATION
WHERE OCCURS
LINE OF CONCRETE CURB
WHERE OCCURS
CONTINUOUS SEALANT , BOTH
SIDES, TOP AND BOTTOM
CONTINUOUS TRACK TO
MATCH STUD SIZE
BOTTOM OF STRUCTURE
CONTINUOUS SEALANT , BOTH
SIDES
CONTINUOUS TRACK TO
MATCH STUD SIZE
CEILING SYSTEM, WHERE
OCCURS SEE REFLECTED
CEILING PLAN
(1) LAYER OF 5/8" TYPE "X"
GYP BD BOTH SIDES, UNO,
SEE FINISH PLANS AND
ELEVATIONS
METAL STUD FRAMING PER
NOTES
ACOUSTICAL INSULATION
WHERE OCCURSUNO0'-6"TYPLINE OF CONCRETE CURB
WHERE OCCURS
BOTTOM OF STRUCTURE
CEILING SYSTEM, WHERE
OCCURS SEE REFLECTED
CEILING PLAN
(1) LAYER OF 5/8" TYPE "X"
GYP BD BOTH SIDES, UNO,
SEE FINISH PLANS AND
ELEVATIONS
METAL STUD FRAMING PER
NOTES
ACOUSTICAL INSULATION
WHERE OCCURS
LINE OF CONCRETE CURB
WHERE OCCURS
CONTINUOUS SEALANT , TOP
AND BOTTOM
CONTINUOUS TRACK TO
MATCH STUD SIZE
STRAP OR BRIDGING
BOTTOM OF STRUCTURE
CEILING SYSTEM, WHERE
OCCURS SEE REFLECTED
CEILING PLAN
(1) LAYER OF 5/8" TYPE "X"
GYP BD BOTH SIDES, UNO,
SEE FINISH PLANS AND
ELEVATIONS
METAL STUD FRAMING PER
NOTES
ACOUSTICAL INSULATION
WHERE OCCURS
LINE OF CONCRETE CURB
WHERE OCCURS
CONTINUOUS SEALANT
CONTINUOUS TRACK TO
MATCH STUD SIZE
STRAP OR BRIDGINGUNO0'-6"
BOTTOM OF STRUCTURE
CEILING SYSTEM, WHERE
OCCURS SEE REFLECTED
CEILING PLAN
(1) LAYER OF 5/8" TYPE "X"
GYP BD BOTH SIDES, UNO,
SEE FINISH PLANS AND
ELEVATIONS
METAL STUD FRAMING PER
NOTES
ACOUSTICAL INSULATION
WHERE OCCURS
LINE OF CONCRETE CURB
WHERE OCCURS
CONTINUOUS FIRE CAULKING,
BOTH SIDES, TOP AND
BOTTOM
CONTINUOUS TRACK TO
MATCH STUD SIZE
STRUCTURE
CEILING SYSTEM, WHERE
OCCURS SEE REFLECTED
CEILING PLAN
(1) LAYER OF 5/8" TYPE "X"
GYP BD , SEE FINISH PLANS
AND ELEVATIONS
CH METAL STUD FRAMING PER
NOTES
ACOUSTICAL INSULATION
WHERE OCCURS
LINE OF CONCRETE CURB
WHERE OCCURS
CONTINUOUS FIRE CAULKING ,
TOP AND BOTTOM
CONTINUOUS J TRACK TO
MATCH STUD SIZE
1" SHAFT WALL LINER ON
INACCESSIBLE SIDE OF
PARTITION
BOTTOM OF STRUCTURE
SHAFT
SIDE
SEE ASSEMBLY
NOTES BELOW
BOTTOM OF STRUCTURE
METAL STUD FRAMING PER
NOTES
LINE OF CONCRETE CURB
WHERE OCCURS
CONTINUOUS SEALANT , BOTH
SIDES, TOP AND BOTTOM
CONTINUOUS TRACK TO
MATCH STUD SIZE
R-19 BATT INSULATION
(1) LAYER OF 5/8" TYPE
"X" MOISTURE
RESISTANT GYP BD, SEE
FINISH PLANS AND
ELEVATIONS
(1) LAYER OF 5/8" TYPE
"X" GYP BD, SEE FINISH
PLANS AND ELEVATIONS
MECHANICAL ROOM
BOTTOM OF STRUCTURE
METAL STUD FRAMING PER
NOTES
LINE OF CONCRETE CURB
WHERE OCCURS
CONTINUOUS FIRE CAULKING,
BOTH SIDES, TOP AND
BOTTOM
CONTINUOUS TRACK TO
MATCH STUD SIZE
(1) LAYER OF 5/8" TYPE "X"
MOISTURE RESISTANT
GYP BD, SEE FINISH PLANS
AND ELEVATIONS
(1) LAYER OF 5/8" TYPE
"X" GYP BD, SEE FINISH
PLANS AND ELEVATIONS
MECHANICAL ROOM
R-19 BATT INSULATION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 3" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
PARTITION TYPES
A9.01
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGSAPARTITION TYPE "SA"SBPARTITION TYPE "SB"SDPARTITION TYPE "SD"SEPARTITION TYPE "SE" SA Walls
WALL TYPE STUD SIZE
SA4
SA8
SB Walls
WALL TYPE STUD SIZE
SD Walls
WALL TYPE STUD SIZE
SD1
SD4 4" STUDS
SD6 6" STUDS
SD8 8" STUDS
SE Walls
WALL TYPE STUD SIZE
SE4 4" STUDS
SE8 8" STUDS
SNPARTITION TYPE "SN" (1HR)
SN Walls
WALL TYPE STUD SIZE
SN4 4" STUDS
SN8 8" STUDS
SSPARTITION TYPE "SS" (1HR PARTITION)
SS Walls
WALL TYPE STUD SIZE
SS6 5" CH STUDS
SJPARTITION TYPE "SJ"SKPARTITION TYPE "SK" (1 HR PARTITION) SJ Walls
WALL TYPE STUD SIZE
SJ6 6" STUDS
SK Walls
WALL TYPE STUD SIZE
SK6 6" STUDS
WALL TYPE PER FLOOR PLAN
EXTRUDED ALUMINUM DOOR
FRAME
DOOR PER DOOR SCHEDULE
ALUMINUM FRAME, BEYOND
FIXED PANEL
HANDLE
1/4" VISION GLAZING
EXTRUDED ALUMINUM FRAME
FLOOR FINISH PER FINISH PLANS
PRESSURE TREATED OR PLASTIC
SHIM AS REQUIRED
SEALANT AND BACKER ROD,
BOTH SIDES
FINISH FLOOR
SLIDING DOOR THRESHOLDFIXED PANELRECESSED TRACK
WALL TYPE PER FLOOR PLAN
EXTRUDED ALUMINUM DOOR
FRAME
DOOR PER DOOR SCHEDULE
ALUMINUM FRAME, BEYOND
BI PARTING SLIDING DOOR HEAD
FIXED PANELALUMINUM FRAME, FULL
TRIM PROFILE.
WALL, PER PARTITION PLAN
METAL STUD FRAMING, REFER
TO STRUCTURAL DETAILS
DOOR PER PLAN
U.O.N.
4"TYP.
ALUMINUM FRAME, FULL
TRIM PROFILE
LINE OF ADJACENT WALL
WHERE OCCURS.
5/8" GYPSUM BOARD
DOOR PER SCHEDULE
METAL STUD FRAMING
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 3" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
INTERIOR DOOR
DETAILS
A9.11
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 3" = 1'-0" A9.11 15INT SLIDING DOOR JAMB - ALUMINUM
3" = 1'-0"
A9.11 14ALUM FRAME SILL
3" = 1'-0"
A9.11 16BI PART SLIDING DOOR HEAD - ALUMINUM 3" = 1'-0"04INT DOOR HEAD 3" = 1'-0"03INT DOOR JAMB (HEAD SIM)
CONCRETE DECK
AT CONCRETE METAL DECK:
ATTACH WITH 1/4" DIA.
CONCRETE SCREWS WITH
2" MIN. EMBEDMENT PER
F/S0.01 AT METAL DECK:
ATTACH WITH #12 SHEET
METAL SCREWS
(2) #12 TEKS
(HEX HEAD)
SELF DRILLING
FASTENERS
COMPRESSION
STRUT, SEE
10/A9.30
METAL STUD
TRACK TO
MATCH STRUT
CEILING PANEL
CONTINUOUS BLOCKING
OR WITHIN 1/4" OF THE
LENGTH OF THE END
TEE, WHICHEVER IS
LEAST
7/8"3/4"
8" MAX OR WITHIN 1/4" OF
THE LENGTH OF THE END
TEE, WHICHEVER IS
LEAST.
2" BERC CLIP WITH
3/4" CLEARANCE
(ICC-ESR-1308)
MAIN "T" @ 48" OC
CROSS "T" @ 24" OC
12 GA HANGER WIRES AT
4'-0" OC EA WAY W/ (3)
TIGHT TURNS IN 3"
SECURE WIRES TO
STRUCTURE
ABOVE, REFER TO
12 GA HANGER WIRES AT
4'-0" OC EA. WAY W/ (3)
TIGHT TURNS IN 3"
AT METAL STUD WALL: #10
SMS, AT MASONRY WALL:
1/4" MASONRY SCREWS WITH
2-1/2" EMBED PER F/S0.01,
AT CONCRETE WALL:
1/4" CONCRETE SCREWS
WITH 2-1/2" EMBED PER
F/S1.O1
0'-8"MAX 14
A9.21
OR WITHIN 1/4" OF THE
LENGTH OF THE END
TEE, WHICHEVER IS
LEAST.
7/8"
12 GA HANGER WIRES AT
4'-0" OC EA WAY WITH (3)
TIGHT TURNS IN 3"
MAIN "T" @ 48" OC
CROSS "T" @ 24" OC
CEILING PANEL
METAL STUD BLOCKING
SECURE WIRES TO
STRUCTURE ABOVE,
REFER TO
ANGLE CLIP AT
TRANSITION
12 GA HANGER WIRES AT
4'-0" OC EA WAY W/ (3)
TIGHT TURNS IN 3"
2" BERC CLIP
ATTACHED TO
PERIMETER ANGLE
(ICC- ESR-1308)
SCREW TIGHTENED
THROUGH MAIN RUNNER
WEB RESTRICTING
SEPARATION FROM WALL
MOLDING
AT METAL STUD WALL: #10
SMS, AT MASONRY WALL:
1/4" MASONRY SCREWS
WITH 2-1/2" EMBED
XXX
X
XXX
X
0'-8"MAX
8" MAX OR WITHIN 1/4"
OF THE LENGTH OF
THE END TEE,
WHICHEVER IS LEAST.
12 GA VERTICAL HANGER WIRE
AT 4'-0" EA WAY WITH MIN 3
TIGHT TURNS IN 3" BOTH ENDS
OF WIRE, TYPICAL.
COMPRESSION STRUTS REQ
AT EA SET OF BRACING
WIRES, TYP ATTACH
COMPRESSION STRUT TO
MAIN RUNNER WITHIN 2" OF
CROSS RUNNER.
(4)-12 GA SPLAYED WIRES 90
DEGREES APART HORIZ WITH
MIN 4 TIGHT TURNS IN 1-1/2"
BOTH ENDS OF WIRE TYPICAL.
WIRES SHOULD BE TAUT
WITHOUT CAUSING THE
CEILING TO LIFT- NO SPLICES
PERMITTED.
45° MAX
VERT TYP
2" MAX. FROM BRACING
WIRES TO CROSS
RUNNERS
MAIN RUNNER
DXT-26
(DOWN)
CROSS RUNNER
DTX-218, 424
(DOWN)
COMPRESSION STRUTS: STEEL
SECTION WITH L/R RATIO OF 200
MAX. COMPRESSION STRUT
SHALL NOT REPLACE HANGER
WIRE. COMPRESSION STRUT NOT
REQUITED AT AREAS LESS THAN
1000 SF. REFER TO
1. 2.
NOTES:
FOR CONNECTIONS OF BRACING & HANGER WIRES TO THE
STRUCTURE ABOVE, REFER TO
FOR CONNECTIONS OF HANGER WIRES @ BARE MTL DECK,
REFER TO
XXX
X
XXX
X
XXX
X
CROSS RUNNER
DXT-218, 424
(DOWN)
AT STEEL BEAMS
SPLAYED SEISMIC BRACING
WIRE TEST FOR 440 LBS
VERT HANGER WIRE
TEST FOR 200 LBS
1"W x 2"L x 13 GA MIN
MTL CLIP
STRUCTURAL STL BEAM
POWER ACTUATED FASTENER,
PER GENERAL NOTES ON S0.01
CONC AND
MTL DECK PER
STRUCT
CONC AND MTL DECK
PER STRUCT
NOTE:
NO FASTENERS SHALL BE DRIVEN UNTIL CONC HAS
REACHED ITS FULL COMPRESSIVE STRENGTH.
AT STEEL DECK
XXX
X
XXX
X
5/8"
STRUCTURAL STL FRAMING
BEYOND
(2) #8 x 1/2" SELF TAPPING SMS
12 GA MIN STL STRAP, 3"W x 4"L,
BEND TO ALIGN WITH WIRE
CABLE BRACE (12 GA MIN)
MTL DECK PER
STRUCTURAL
VERT HANGER WIRE 12 GA MIN
(TEST FOR 200# MAX LOAD)
HANGER WIRE-TIE TO #3
REBAR WITH (3) WRAPS
AROUND REBAR AND (1)
WRAP AROUND WIRE
#3 x 12" REBAR
3/8" DIA (MIN) DRILL-IN
EXPANSION ANCHOR
STL STRAP
3"W x 4"L x 12 GA MIN
BEND TO ALIGN WITH WIRE
SPLAYED SEISMIC
BRACING WIRE SECURE
TO CLIP WITH (4 )TIGHT
TURNS IN 1-1/2"
HILTI "X-CC" CLG CLIP
ICC ESR-2184
1. 2.
3. 4.
NOTES:
NO FASTENERS SHALL BE DRIVEN UNTIL CONC HAS REACHED ITS FULL COMPRESSIVE STRENGTH.
SHOT IN ANCHORS NOT ALLOWED FOR BRACING WIRES.
1 OUT OF 10 HANGER WIRE/ANCHOR ASSEMBLIES SHALL BE FIELD TESTED FOR 200 LBS IN TENSION. 1 OUT OF 2 BRACING WIRE ASSEMBLIES SHALL BE FIELD TESTED FOR 400 LBS IN TENSION IN THE DIRECTION OF THE WIRE.
VERT HANGER WIRE
SECURE TO CLIP
WITH (3 )TIGHT
TURNS IN 1-1/2"
(B) VERTICAL HANGER WIRE CLIP
ATTACHMENT
(A) SPLAYED BRACING WIRE CLIP
ATTACHMENT
5/8" MAXMAX45.00
°
STRUCTURAL CONC
SHOT-IN ANCHOR
3/4" (MIN)
PENETRATION OR
DRILLED-IN ANCHOR
STRUCTURAL CONC
5/8" MAX3" EMBEDEDGE DIST
1-1/8" MIN
1"1 1/2"1 1/2" FURRING STRIPS
24" OC OR EQUAL
TECTUM DIRECT-ATTACH
PANEL
2-1/2" BATT
INSULATION
FASTENER PER MFR
GL
1/2"
#12 VERTICAL
HANGER WIRE
ARMSTRONG SJCG
SEISMIC EXPANSION
JOINT CLIP
FASTENERS TO
ALLOW LATERAL
MOVEMENT IN
SLOTTED TRACK
CROSS TEES
MAIN RUNNER
FOR SEISMIC CEILINGS
EXCEEDING 2,500 S.F.
PROVIDE SEISMIC
EXPANSION JOINT CLIPS.
SEE REFLECTED CEILING
PLAN FOR LOCATIONS
(a) SJCG CLIP
a
-
WALL PER PLAN
STEEL STRAP
3" WIDE x 4" LONG x 10 GA. MIN.
10 GA. HANGER WIRE WITH
MIN. 3 TIGHT TURNS IN 1 1/2"
AT SPLAYED WIRE MAX3/4"AT VERTICAL HANGER
WIRE WALL PER PLAN
STEEL STRAP
3" WIDE x 4" LONG x 10 GA.
MIN.
10 GA. HANGER WIRE WITH
MIN. 3 TIGHT TURNS IN 1 1/2"MAX3/4"NOTE:
1. AT METAL STUD WALLS,
PROVIDE BACKING AS
REQUIRED.
AT METAL STUD WALL: #10 S.M.S.
AT MASONRY WALL: 1/4" MASONRY
SCREWS WITH 2-1/2" EMBEDED
AT METAL STUD WALL: #10 S.M.S.
AT MASONRY WALL: 1/4" MASONRY
SCREWS WITH 2-1/2" EMBEDED
MIN OPNG 22"x30"
DOUBLE STUD FRAMING, TYP
HINGE
STEEL FRAME
KEYLOCK & PULL
J MOLDING TYP
PAINTED GYP BD
EQ EQ EQ EQ
LIGHT FIXTURE, TYP
TYPICAL ELECTRICAL/ FIRE
PROTECTION DEVICE
SPEAKER
MECHANICAL DIFFUSER
EQ EQ
1. 2.
3. 4.
5. NOTES:
CENTER DEVICE ON LIGHT FIXTURE OR MECHANICAL DIFFUSER
WHERE OCCURS IN CORRIDORS
IN ACT CEILINGS, CENTER DEVICES IN CEILING TILE, NO MORE THAN TWO DEVICES PER 2x4 TILE.
IN ACT CLGS, IF ONLY ONE DEVICE OCCURS, CENTER DEVICE IN TILE, BOTH DIRECTIONS.
WHERE MULTIPLE DEVICES OCCUR, CONSOLIDATE INTO ONE AREA
WHERE POSSIBLE
REFER TO LAY-IN CEILING REQUIREMENTS FOR DEVICE, SERVICE, AND LIGHTING SUPPORT AND ATTACHMENT.
CONDITION AT ACT CEILING
CONDITION AT GYP CEILING
FULL TILE
HALF TILE HALF TILE
EQ.EQ.FULL TILEEQEQNOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 As indicatedCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
CEILING DETAILS
A9.21
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 3" = 1'-0" A9.21 05COMPRESSION STRUT @ DECK
3" = 1'-0"06OPP. WALL OF STARTER WALL
(FREE END)
3" = 1'-0"
A9.21 07PERIMETER STARTER WALL
12" = 1'-0"
A9.21 08SPLAY BRACING DETAIL 1 1/2" = 1'-0"
A9.2116WIRE CONNECTIONS TO STL BEAMS & STL DECK
3" = 1'-0"
A9.2114WIRE CONNECTION TO MTL DECK
6" = 1'-0"
A9.2115WIRE CONNECTION @ STL DECK WITH CONCRETE INFILL
3" = 1'-0"
A9.21 09TECTUM CEILING ATTACHMENT
12" = 1'-0"04CEILING SEISMIC EXPANSION
JOINTS
6" = 1'-0"03SEISMIC BRACING
CONNECTIONS TO WALL
1 1/2" = 1'-0"02HORIZONTAL ACCESS PANEL 1/2" = 1'-0"10TYPICAL DEVICE LAYOUT
PERIMETER STARTER WALLS,
GRID ATTACHED TO
(2) ADJACENT WALLS
BRACING ASSEMBLIES, TYP.
12 GA. HANGER WIRES AT 4'-0" O.C.
EACH WAY ALONG MAIN RUNNERS
12 GA. HANGER WIRES
AT 8" FROM ALL WALLS
AT ALL MAIN RUNNERS
& CROSS TEES
OPPOSITE FREE WALLS,
NO GRID ATTACHMENT-
3/4" MIN. CLEAR
FIXTURES, SUPPORT
PER AND
CROSS TEES
AT 24" O.C.
MAIN
RUNNERS
AT 48" O.C.
NOTES:
1. CLASSIFICATION OF CEILING GRID IS: HEAVY DUTY - REFER TO SPECIFICATIONS.
1. CEILING SYSTEM GENERAL NOTES
1.01 CEILING SYSTEM COMPONENTS SHALL COMPLY WITH ASTM C635 AND SECTION 5.1 OF ASTM E580.
1.02 THE CEILING GRID SYSTEM MUST BE RATED HEAVY DUTY AS DEFINED BY ASTM C635.
1.03 CEILING SYSTEMS. THE FOLLOWING CEILING SYSTEM(S) IS/ARE PART OF THE SCOPE OF THIS PROJECT:
MANUFACTURER: ARMSTRONG WORLD INDUSTRIES, INC.
PRODUCT NAME: ULTIMA HIGH NRC WITH SUPRAFINE XL GRID
EVALUATION REPORT TYPE AND NUMBER: ICC ESR-1308
MAIN RUNNER PART, MODEL, OR CATALOG NUMBER: 7501 HRC
CROSS RUNNER PART, MODEL, CATALOG NUMBER: XL7549 HRC
1.04 SEISMIC WALL CLIP:
MANUFACTURER’S MODEL: ARMSTRONG BERC-2
1.05 CEILING PANELS SHALL NOT SUPPORT ANY LUMINAIRES, AIR TERMINALS OR DEVICES.
1.06 FOR CEILING INSTALLATIONS UTILIZING ACOUSTICAL TILE PANELS OF MINERAL OR GLASS FIBER, IT IS NOT MANDATORY TO PROVIDE ¾”
CLEARANCE BETWEEN THE ACOUSTICAL TILE PANELS AND THE WALL ON THE SIDES OF THE CEILING WHICH ARE FREE TO SLIP. FOR ALL OTHER CEILING PANEL TYPES, PROVIDE ¾” CLEARANCE BETWEEN THE CEILING PANEL AND THE WALL ON THE SIDES OF THE CEILING FREE TO SLIP.
CLEARANCE BETWEEN CEILING GRID RUNNERS/MEMBERS AND WALLS
SHALL COMPLY WITH THE DETAILS ON THESE DRAWINGS REGARDLESS OF CEILING TILE MATERIAL.
2. MATERIALS
2.01 CEILING WIRE SHALL BE CLASS 1 ZINC COATED (GALVANIZED) CARBON STEEL CONFORMING TO ASTM A641. WIRE SHALL BE #12 GAUGE (0.106”
DIAMETER) WITH SOFT TEMPER AND MINIMUM ULTIMATE TENSILE STRENGTH = 70 KSI.
2.02 GALVANIZED SHEET STEEL (INCLUDING THAT USED FOR METAL STUD AND TRACK COMPRESSION STRUTS/POST) SHALL CONFORM TO ASTM A653, OR OTHER EQUIVALENT SHEET STEEL LISTED IN SECTION A3.1 OF THE NORTH
AMERICAN SPECIFICATION FOR THE DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS, (AISI S100). MATERIAL 43 MIL (18 GAUGE) AND LIGHTER SHALL HAVE MINIMUM YIELD STRENGTH OF 33 KSI. MATERIAL 54 MIL (16 GAUGE) AND HEAVIER SHALL HAVE A MINIMUM YIELD STRENGTH OF 50KSI.
2.03 ELECTRICAL METALLIC TUBE (EMT) SHALL BE ANSI C80.3/UL 797 CARBON STEEL WITH G90 GALVANIZING. EMT SHALL HAVE MINIMUM YIELD STRENGTH (FY) OF 30 KSI AND MINIMUM ULTIMATE STRENGTH (FU) OF 48 KSI.
3. ATTACHMENT OF HANGER AND BRACING WIRES
3.01 SEPARATE ALL CEILING HANGER AND BRACING WIRES AT LEAST 6 INCHES FROM ALL UNBRACED DUCTS, PIPES, CONDUIT, ETC.
3.02 HANGER AND BRACING WIRES SHALL NOT ATTACH TO OR BEND AROUND
OBSTRUCTIONS INCLUDING BUT NOT LIMITED TO PIPING, DUCTWORK, CONDUIT AND EQUIPMENT.
3.03 HANGER WIRES THAT ARE MORE THAN ONE (HORIZONTAL) IN SIX (VERTICAL) OUT OF PLUMB SHALL HAVE COUNTER-SLOPING WIRES.
3.04 SLACK SAFETY WIRES SHALL BE CONSIDERED HANGER WIRES FOR INSTALLATION AND TESTING REQUIREMENTS.
3.05 HANGER AND BRACING WIRE ANCHORAGE TO THE STRUCTURE SHALL BE
INSTALLED IN SUCH A MANNER THAT THE DIRECTION OF THE ANCHORAGE ALIGNS CLOSELY WITH THE DIRECTION OF THE WIRE (E.G., BRACING WIRE
CEILING CLIPS MUST BE BENT AS SHOWN IN THE DETAILS AND ROTATED AS
REQUIRED TO ALIGN CLOSELY WITH THE DIRECTION OF THE WIRE, SCREW
EYES IN WOOD MUST BE INSTALLED SO THEY ALIGN CLOSELY WITH THE DIRECTION OF THE WIRE, ETC.).
4. FASTENERS AND WELDING
4.01 SHEET METAL SCREWS SHALL COMPLY WITH ASTM C1513 AND ASME B18.6.3.
PENETRATION OF SCREWS THROUGH JOINED MATERIAL SHALL NOT BE LESS THAN THREE EXPOSED THREADS.
4.02 EXPANSION ANCHORS SHALL BE: NOT USED
4.03 POWER-ACTUATED FASTENERS SHALL BE: NOT USED
4.04 IF NOT OTHERWISE SPECIFIED IN THE EVALUATION REPORT,
POWER-ACTUATED FASTENERS INSTALLED IN STEEL SHALL BE INSTALLED
SO THE ENTIRE POINTED END OF THE FASTENER IS DRIVEN THROUGH THE
STEEL MEMBER
4.05 POWER-ACTUATED FASTENERS IN CONCRETE OR MASONRY ARE NOT PERMITTED FOR BRACING WIRES.
4.06 CONCRETE REINFORCEMENT AND PRESTRESSING TENDONS SHALL BE
LOCATED BY NON-DESTRUCTIVE MEANS PRIOR TO INSTALLING POST INSTALLED ANCHORS.
4.07 WELDING SHALL BE IN ACCORDANCE WITH AWS D1.3 USING E60XX SERIES ELECTRODES.
5. TESTING
5.01 ALL FIELD TESTING MUST BE PERFORMED IN THE PRESENCE OF THE PROJECT INSPECTOR.
5.02 POST-INSTALLED ANCHORS IN CONCRETE USED TO SUPPORT HANGER WIRES SHALL BE TESTED AT A FREQUENCY OF 10 PERCENT. POWER
ACTUATED FASTENERS IN CONCRETE SHALL BE FIELD TESTED FOR 200 POUNDS IN TENSION. ALL OTHER POST-INSTALLED ANCHORS IN
CONCRETE SHALL BE TESTED IN ACCORDANCE WITH CBC SECTION 1910A.5.
5.03 POST-INSTALLED ANCHORS IN CONCRETE USED TO ATTACH BRACING WIRES SHALL BE TESTED AT A FREQUENCY OF 50 PERCENT IN
ACCORDANCE WITH CBC SECTION 1910A.5.
6. LUMINAIRES
6.01 ALL LUMINAIRES SHALL BE POSITIVELY ATTACHED TO THE CEILING
SUSPENSION SYSTEMS BY MECHANICAL MEANS TO RESIST A HORIZONTAL FORCE EQUAL TO THE WEIGHT OF THE LUMINAIRE. A MINIMUM OF TWO
SCREWS OR APPROVED FASTENERS ARE REQUIRED AT EACH LUMINAIRE, PER ASTM E580 SECTION 5.3.1.
6.02 SURFACE-MOUNTED LUMINAIRES SHALL BE ATTACHED TO THE MAIN RUNNER WITH AT LEAST TWO POSITIVE CLAMPING DEVICES. THE
CLAMPING DEVICE SHALL COMPLETELY SURROUND THE SUPPORTING
CEILING RUNNER AND BE MADE OF STEEL WITH A MINIMUM THICKNESS OF #14 GAUGE. ROTATIONAL SPRING CATCHES DO NOT COMPLY. A #12
GAUGE SLACK SAFETY WIRE SHALL BE CONNECTED FROM EACH
CLAMPING DEVICE TO THE STRUCTURE ABOVE. PROVIDE ADDITIONAL SUPPORTS WHEN A LUMINAIRE IS 8 FEET OR LONGER OR EXCEEDS 56 POUNDS. MAXIMUM SPACING BETWEEN SUPPORTS SHALL NOT EXCEED 8 FEET.
6.03 LUMINAIRES WEIGHING LESS THAN OR EQUAL TO 10 POUNDS MAY BE
SUPPORTED DIRECTLY ON THE CEILING RUNNERS, SHALL HAVE A MINIMUM OF ONE #12 GAUGE SLACK SAFETY WIRE CONNECTED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE.
6.04 LUMINAIRES WEIGHING GREATER THAN 10 POUNDS BUT LESS THAN OR EQUAL TO 56 POUNDS MAY BE SUPPORTED DIRECTLY ON THE CEILING RUNNERS, BUT THEY SHALL HAVE A MINIMUM OF TWO #12 GAUGE SLACK
SAFETY WIRES CONNECTED FROM THE FIXTURE HOUSING AT DIAGONAL CORNERS TO THE STRUCTURE ABOVE.
EXCEPTION: ALL LUMINAIRES GREATER THAN TWO BY FOUR FEET WEIGHING LESS THAN 56 POUNDS SHALL HAVE A #12 GAUGE SLACK SAFETY WIRE AT EACH CORNER.
6.05 ALL LUMINAIRES WEIGHING GREATER THAN 56 POUNDS SHALL BE INDEPENDENTLY SUPPORTED BY NOT LESS THAN FOUR TAUT #12 GAUGE
HANGER WIRES (ONE AT EACH CORNER) ATTACHED FROM THE FIXTURE HOUSING TO THE STRUCTURE ABOVE OR OTHER APPROVED HANGERS.
THE FOUR TAUT #12 GAUGEWIRES OR OTHER APPROVED HANGERS,
INCLUDING THEIR ATTACHMENT TO THE STRUCTURE ABOVE, SHALL BE CAPABLE OF SUPPORTING FOUR TIMES THE WEIGHT OF THE FIXTURE.
7. SERVICES WITHIN THE CEILING
7.01 ALL FLEXIBLE SPRINKLER HOSE FITTING MOUNTING BRACKETS, CEILING
MOUNTED AIR TERMINALS OR OTHER SERVICES SHALL BE POSITIVELY
ATTACHED TO THE CEILING SUSPENSION SYSTEMS BY MECHANICAL MEANS. SCREWS OR APPROVED FASTENERS ARE REQUIRED. A MINIMUM OF TWO ATTACHMENTS ARE REQUIRED AT EACH COMPONENT.
7.02 CEILING-MOUNTED AIR TERMINALS OR OTHER SERVICES WEIGHING LESS THAN OR EQUAL TO 20 POUNDS SHALL HAVE ONE #12 GAUGE SLACK
SAFETY WIRE ATTACHED FROM THE TERMINAL OR SERVICE TO THE STRUCTURE ABOVE.
7.03 FLEXIBLE SPRINKLER HOSE FITTINGS, CEILING-MOUNTED AIR TERMINALS OR OTHER SERVICES WEIGHING MORE THAN 20 POUNDS BUT LESS THAN OR EQUAL TO 56 POUNDS SHALL HAVE TWO #12 GAUGE SLACK SAFETY
WIRES (AT DIAGONAL CORNERS) CONNECTED FROM THE TERMINAL OR SERVICE TO THE STRUCTURE ABOVE.
7.04 FLEXIBLE SPRINKLER HOSE FITTINGS, CEILING-MOUNTED AIR TERMINALS OR OTHER SERVICES WEIGHING MORE THAN 56 POUNDS SHALL BE
SUPPORTED DIRECTLY FROM THE STRUCTURE ABOVE BY NOT LESS THAN FOUR TAUT #12 GAUGE HANGER WIRES ATTACHED FROM THE TERMINAL
OR SERVICE TO THE STRUCTURE ABOVE OR OTHER APPROVED
HANGERS.
8. OTHER DEVICES WITHIN THE CEILING
8.01 ALL LIGHTWEIGHT MISCELLANEOUS DEVICES, SUCH AS STROBE LIGHTS, OCCUPANCY SENSORS, SPEAKERS, EXIT SIGNS, ETC., SHALL BE ATTACHED TO THE CEILING GRID. IN ADDITION, DEVICES WEIGHING MORE THAN 10 POUNDS SHALL HAVE A #12 GAUGE SLACK SAFETY WIRE ANCHORED TO THE STRUCTURE ABOVE. DEVICES WEIGHING MORE THAN 20 POUNDS SHALL BE SUPPORTED INDEPENDENTLY FROM THE
STRUCTURE ABOVE.
REQUIREMENTS FROM DSA IR 25-2 (REVISED 03/18/2022)
6'-0" MAX.12'-0" MAX. 6'-0" MAX.4'-0" MAX.8'-0" MAX. 4'-0" MAX.
CONT. ANGLE AT PERIMETER
ROOF OR FLOOR STRUCTURE
BRACE WIRE: SEE DETAIL
(2) 1/4"DIA. MACHINE BOLT
CROSS RUNNER
MAIN RUNNER
HANGER WIRE
4 TIGHT TURNS IN 1 1/2" TYP.
FOR BRACE WIRE
3 TIGHT TURNS IN 3"
FOR HANGER TYP.
1 1/2" MAX.TYP0º
TO
45 ºDISTANCE, TYP.3/4" MIN. EDGE"L" (SEE NOTE 1 BELOW)CHANNEL TYPE COMPRESSION STRUT PER TABLE; CENTER
OVER CROSS RUNNER
1 1/2" MAX.
MAX.
4'-0" O.C.
3/4" MIN. TYP.1" MAX
A
1. NOTES:
DIMENSION "L" SHALL
NOT EXCEED THE
ALLOWABLE LENGTH
GIVEN IN THE TABLE FOR
THE COMPRESSION
STRUT SECTION USED.
MAIN RUNNER
CROSS RUNNER
BRACE WIRE
BEYOND
HANGER WIRE
BEYOND
COPE FLANGE OR
FLATTEN TO ALLOW
INSTALLATION OF
ACOUSTICAL TILE
5' - 10"
MAXIMUM
LENGTH
250S137-33
362S137-33
250S137-43
400S137-43
250S125-33
6' - 10"
8' - 0"
8' - 10"
10' - 10"
COMPRESSION STRUT
CHANNEL SECTION
SECTION A
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 As indicatedCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
CEILING DETAILS
A9.22
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 6" = 1'-0"01CEILING REQUIREMENTS 1 1/2" = 1'-0"04COMPRESSION STRUT
(2) #8 SMS @ EACH STUD
FULL LENGTH WELD AT WEB
AND FLANGES OF BACKING
TRACK TO STUD, TYPICAL
6" x 16 GA. BACKING
TRACK NOTCHED AROUND
STUDS, ( ONE BAY BEYOND
CABINET, BRACKETS, ETC).
STUD PER PLAN
DOUBLE STUDS AT SIDES
OF OPENING
BACKING TRACK - TYPE 'B'
1. 2.
3. 4.
5. BACKING TRACK TYPE 'A' - FOR MISCELLANEOUS ITEMS I.E.
SURFACE MOUNTED MIRRORS, WASTE RECEPTACLES,
TOWEL DISPENSERS, ETC., MAXIMUM WEIGHT: 50
POUNDS.
BACKING TRACK TYPE 'B' - FOR UPPER WALL-HUNG
CABINETS (UP TO 2 SHELVES), BASE CABINETS, FULL
HEIGHT CABINETS, FILM VIEWING COUNTER, WALL-HUNG
BENCHES, HANDRAILS, GUARDRAILS, GRAB BARS, WALL-
HUNG EQUIPMENT, TOWEL BARS, ETC., MAXIMUM WEIGHT:
250 POUNDS.
VERIFY LENGTH, HEIGHT, LOCATION OF BACKING PLATE &
NUMBER REQUIRED WITH EQUIPMENT ACCESSORY
MANUFACTURERS.
USE #12 SELF TAPPING SHEET METAL SCREWS WHEN
ATTACHING ITEMS TO METAL BACKING PLATE.
WALL STUD FLANGES ARE CONTINUOUS.BACKING TRACKS
SHALL BE LONGER THAN HUNG EQUIPMENT, ACCESSORY,
CABINET BY ONE STUD SPACING AT EACH END (ALL
CONDITIONS).
BACKING TRACK NOTES:
(3) #10 F.H.S.M.S. @
EACH STUD
6" x 54 MIL. UNPUNCHED
BACKING NOTCHED
AROUND STUDS
STUD PER PLAN (MIN 16 GA)
DOUBLE STUDS AT SIDES
OF OPENING
BACKING TRACK - TYPE 'A'
3/8" MIN.3/8" MIN.
SPLICE
CONDITION
TYP.3/4
"
M
IN
.
1/16
IN LIEU OF
SCREWS
NOTE:
BLOCK & ANCHOR EACH SIDE OF CABINET.
3/4" TYPE 1-M-2
PARTICLE BOARD
(CABINET SIDE)
#10 x 2 1/2" RHWS
@ 6" O.C.
1/2" HARDWOOD CABINET RAIL
2"x6" WOOD BLOCKING
(LENGTH=6")
0.145 DIA LOW VELOCITY
FASTENERS (1-1/8" EMBED)
ICC #2388 @ 24" OC MIN (2 PER
CABINET)
(3) #10 x 3" RHWS @ 6" O.
BASE PER FINISH PLANS &
ELEVATIONS
FINISH FLOOR
DOUBLE 16 GA MTL STUDS AT
ANGLE SUPPORT
2" X 2" X 1/4" STL ANGLE AT
48" OC MAX, MIN (2) ATTACH
TO STUD WITH #12 SMS @ 6"
OC PT TO MATCH WALL
FIN/COLOR
BACKSPLASH WHERE
OCCURS - SEE ELEVATION
COUNTERTOP PER
FINISH PLANS
WALL FINISH PER PLAN
EASED EDGE
UNO ON PLANS
2'-0"
UNO
1'-6"MIN
0'-1 127/128"0'-0 3/4"0'-1 1/2"(34" MAX @ ACCESSIBLE STATION)SEE ELEVATION27" MIN CLR2'-0"UNOMIRROR WHERE OCCURS -
SEE ELEVATION
1. 2.
3. NOTES:
CONSTRUCTION SHALL BE AWS CUSTOM STANDARDS.
FINISH PER FINISH PLANS AND LEGEND.
THERE SHALL BE NO SHARP OR ABRASIVE SURFACES BELOW
THE COUNTER.
CLEAT, TYP PER XXX
INTEGRAL ACCESSIBLE
PLASTIC LAMINATE TOE KICK
AREA NOT HATCHED BELOW SINK
SHALL BE ACCESSIBLE & CLEAR
WRAP HOT & COLD WATER
SUPPLIES AND DRAIN PIPING WITH
PVC INSULATION MATERIAL
COMPLIANT WITH ASTM E84-07, 25
FLAME / 450 SMOKE INDEX
PLASTIC LAMINATE CABINET DOOR
PLASTIC LAMINATE DOOR STOP
PULL PER XXX
COUNTERTOP PER FINISH PLAN
COVED BACKSPLASH (WHERE OCCURS)
CONTINUE ADJ FLOORING
SEE FINISH PLAN
RUBBER BASE INSIDE CABINET
WALL FRAMING AND FINISH PER PLAN
INSULATE SINK BOTTOM IF HOT
WATER PROVIDED
FAUCET CONTROLS TO BE LEVER OR A
TYPE NOT REQUIRING GRASPING,
PINCHING, OR TWISTING OF THE WRIST
W/ 5 LBS FORCE MAX TO OPERATE.TO TOP OF SELF-RIMMING SINK2'-10" MAXMIN0'-9"0'-8"MIN MIN2'-5"(17" MIN) 2'-0"MIN2'-3"0'-1"
6" MAX
17" MIN
1. 2.
NOTES:
SEE 02/A9.60 FOR GENERAL
NOTES.
SEE 02/A9.60 FOR
ADDITIONAL INFORMATION
NOT SHOWN.
PLASTIC LAMINATE DOOR STOP
ADJUSTABLE SHELF,
PLASTIC LAMINATE
FIXED MIDDLE SHELF,
PLASTIC LAMINATE
HORIZ MTD PULL - FINISH TO
MATCH DOOR HDWR
RECESSED HEAVY DUTY
ADJ SHELF SUPPORTS WITH
SHELF CLIPS
4" COVED RUBBER BASE
PLASTIC LAMINATE CABINET
DOOR WHERE OCCURS - SEE
ELEVATIONS (GLASS DOOR
WHERE OCCURS - SEE
ELEVATIONS)0'-4"0'-2"SEE ELEVATIONSUNO NOTED ON PLANS
2'-0"4'-6" MAX4'-0"1.
2. 3.
NOTES:
CONSTRUCTION SHALL BE WIC CUSTOM STANDARDS; PLASTIC LAMINATE PER FINISH
PLANS WITH WHITE THERMALLY FUSED MELAMINE AT CONCEALED INT
FOR BASE ANCHORAGE DETAILS REFER TO
FOR WALL BACKING DETAILS REFER TO
XXX
X
XXX
X
A9.31
01 A9.31
01 A9.31
02 6" X 18" ACCESS PANEL AT
BASE TO PROVIDE ACCESS
TO ELECTRICAL GROUND
BUS BAR - SEE ELECTRICAL
DRAWINGS 0'-6"WIC DESIGN SERIES
SEE INTERIOR ELEVATIONS
SEE ELEVATIONVARIESNAAWS CABINET DESIGN SERIES
SEE INTERIOR ELEVATIONS34" MAXSEE ELEVATIONSEE REFLECTED CEILING PLANADJ SHELVES
CABINET LOCK
LINE OF BOTTOM
SHELF
LIGHT FIXTURE
WHERE SHOWN
HORIZ MTD PULLS, TYP FIN
TO MATCH DOOR HDWR
4" BACKSPLASH
WHERE OCCURS (SEE
ELEVATION)
DRAWER ON FULL
EXTENSION HVY DUTY
GLIDES,WHERE OCCURS
(SEE ELEVATION)
COUNTERTOP NOT TO
EXCEED 1/2" AT CABINET
EXPOSED ENDS
ADJUSTABLE SHELF
BREAK AT ADA ACCESS
TOE KICK WHERE SINK
OCCURS
AT EXPOSED ENDS:
PROVIDE A 2" RECESS
4" COVED RUBBER BASE
ELEVATION0'-4"CLEAR
1'-2 3/4"WALL FRAMING AND FINISH PER PLAN
RECESSED HVY DUTY ADJUSTABLE
SHELF SUPPORTS WITH SHELF CLIPS
PLASTIC LAMINATE ADJ SHELVES
LIGHT FIXTURE WHERE OCCURS
4" COVED BACKSPLASH WHERE OCCURS
(SEE ELEVATION)
DRAWER ON FULL EXTENSION HEAVY
DUTY GLIDES, WHERE OCCURS (SEE
ELEVATION)
ADJ PLASTIC LAMINATE SHELF
SECTION
RECESSED HEAVY DUTY ADJ SHELF
SUPPORTS WITH SHELF CLIPS
FINISHED FLOOR
FINISHED CEILING
(SEE REFLECTED CEILING PLANS)
LOWER CABINET
WITHOUT DRAWER
LOWER CABINET
WITH SINK
COUNTERTOP ONLY
TYP0'-4"0'-2"0'-6"2'-0" MAX
@CMU AND CONC
1. 2.
3. 4.
5. 6.
7. NOTES:
CONSTRUCTION SHALL BE PER THE NORTH AMERICAN ARCHITECTURAL WOODWORK STANDARDS (NAAWS) 'CUSTOM' STANDARDS, LATEST EDITION.
FINISH PER FINISH PLANS AND LEGEND.
WHITE THERMALLY FUSED MELAMINE AT CONCEALED INT OF CABINETS.
SEE 04/A9.60 FOR WALL BACKING.
AT SINKS, WHEN DOORS OPEN 90° PROVIDE FOR 32" MIN CLEAR BETWEEN KICKS.
NO SHARP OR ABRASIVE SURFACES UNDER SINK.
ALL JOINTS TO BE CAULKED WITH CLEAR SILICONE CAULK.
(LOWER CABINET WITH
DRAWER SHOWN)
WALL WHERE OCCURS WALL FRAMING AND
FINISH PER PLAN SEE XXXX. FOR FREE STANDING
MILLWORK SUPPORT
COUNTERTOP (PER ELEVATIONS)
PLASTIC LAMINATE DOOR STOP, TYP
PLASTIC LAMINATE CABINET DOOR
1x4 WALL CLEAT WITH NO 10 x 2" SELF TAPPING
SHEET MTL SCREWS INTO MTL STUDS OR
BLOCKING. ATTACH CABINET TO CLEAT WITH
NO 8 x 1 1/4" WOOD SCREWS @ 16" OC (TYP)
4" COVED RUBBER BASE
ANCHOR PER 03/A9.60, SIM
PLASTIC LAMINATE CABINET DOOR
HORIZ MTD PULL, TYP MATCH DOOR HDWR FINISH
1x4 WALL CLEAT WITH NO 10 x 2" SELF
TAPPING SHEET MTL SCREWS INTO
MTL STUDS OR BLOCKING. ATTACH
CABINET TO CLEAT WITH NO 8 x 1-1/4"
WOOD SCREWS @ 16" OC TYP
HORIZ MTD PULL, TYP MATCH
DOOR HDWR FINISH 6" MAX3' - 0" MAXXXX
X
XXX
X
XXX
X
XXX
X
MIRROR
2'-3" MIN2'-10" TO TOP OF SELF-RIMMING SINK40" TO BOT OF REFLECTIVE SURFACEAT BRACKET, PROVIDE DOUBLE STUDS WITH MIN 4"x16 GA 2'-5" AFF0'-4 253/256"9" MIN1'-5" MIN 0'-11" MIN
0'-8" MIN
NOTE:
SEE GENERAL NOTES #11.
FINISH WALL WHERE OCCURS
PLASTIC LAMINATE PLUMBING
SCREEN MTD W/ "S" HOOKS TO
UNDERSIDE OF COUNTER. 12"
MIN SEE ELEVATIONS
INSTALL TRAP ASSEMBLY AS
HIGH AS CODE ALLOWS TO
CONCEAL FROM VIEW
WALL BASE PER FINISH PLAN
BACKSPLASH WHERE
OCCURS, SIDE SPLASH AT
ADJACENT WALLS
2" X 3" X 1/4" LLV STEEL ANGLE
@ 48" OC MAX - PAINT TO
MATCH WALL FINISH
COVED BACKSPLASH
(WHERE OCCURS)
COUNTERTOP; SEE FINISH PLANS
PULL PER SPECS, TYP
PLAM. BASE
WALL WHERE OCCURS
WALL FRAMING AND
FINISH PER PLAN
HAFELE US CARGO 21 SILVER
502.74.252 WITH (2) GRAY
TRASH BINS
DOOR MOUNT BRACKET
RECESSED 2" DIA. STAINLESS
STEEL DISK WITH ROUTED TRASH
& RECYCLE GRAPHIC, SEE
17/A9.31
0'-6"A9.30
16 TYP
A9.31
02 TYP
RECYCLE SYMBOL ON MATTE
BLACK COIN
ROUTE PLASTIC LAMINATE
TO ACCEPT MATTE BLACK
COIN WITH SYMBOL
TRASH SYMBOL ON MATTE
BLACK COIN1 1/2"1 1/2"NOTE: SUITE 120 AND 150 TO HAVE SS STL TRASH AND RECYCLE COINS. 4" METAL STUD FRAMING
LAYER OF 5/8" GYP. BD.
SEE ELEVATION FOR FINISH
FLOOR FINISH SEE
FINISH PLAN2'-10".1" LAYER OF MDF PLAM
WRAPPED, 3MM
DOELLKEN EDGE
BANDING FINISH TO
MATCH ADJ. P. LAM.
WALL BASE SEE FINISH
PLANPAINTED TO MATCH0'-0 1/4" REVEAL1/4" WOOD CONT.
BLOCKING, TYP.
PLAN VIEW
REFERENCE
FOR PLAM
SEAM
LOCATION
TOP OF PLINTH,
STRUCTURAL
BRACING ABOVE
SCRIBE PLAM
INTO EDGE
3'-0".
EQ.EQ
DIAGONAL BRACING AT
48" O.C. (ALTERNATING
DIRECTIONS)
SCRIBE EDGE INTO
BRACE FRAME
OPENINGBRACE FRAMEEQUALEQUALTYP. CORNER BEAD
STRUCTURAL BRACING
WHERE OCCURS
CONT. 3" MTL. ANGLE, TYP.
SOLID SURFACE
PER PLAN
WALL PER SCHEDULE
METAL STUD PER PLAN W/
ONE LAYER OF 5/8" GYP. BD.
BOTH SIDES
SEE ELEVATION FOR FINISHTOP OF COUNTER 2'-10"1" LAYER OF MDF PLAM WRAPPED, 3MM DOELLKEN
EDGE BANDING FINISH TO
MATCH ADJ. P. LAM.
WALL BASE SEE FINISH
PLANPAINTED TO MATCH0'-0 1/4" REVEAL1/4" WOOD BLOCKING, TYP. 3'-0".
EQUALEQUAL
STRUCTURAL BRACING
BEYOND
SCRIBE EDGE INTO BRACE
FRAME
EQUIPMENT
PER
SCHEDULE
2" X 3" X 1/4" LLV STL ANGLE
@ 36" OC MAX - PROVIDE
DOUBLE STUDS WITH MIN
4"x16 GA.
2 1/2" METAL STUDS W/ ONE
LAYER OF 5/8" GYP. BD. BOTH
SIDES
SEE ELEVATION FOR FINISH
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 As indicatedCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
CASEWORK
DETAILS
A9.31
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 3/8" = 1'-0" A9.31 01BACKING TRACK AND SUPPORT
3" = 1'-0"
A9.31 02CABINET ANCHORAGE
1" = 1'-0"
A9.31 09TYP. COUNTER SUPPORT (AS REQ'D.)
1" = 1'-0"
A9.31 06LOWER CABINET WITH SINK
1" = 1'-0"
A9.3115TALL CABINET 1" = 1'-0"
A9.31 03TYPICAL UPPER/LOWER CABINETS
1" = 1'-0"10RESTROOM SINK COUNTER
1" = 1'-0"13PULL-OUT TRASH 12" = 1'-0"17PULL-OUT COIN1
1 1/2" = 1'-0"18TYP. COUNTER IN OFFICE
1 1/2" = 1'-0"19OPEN OFFICE 406 - PLINTH SECTION
PROVIDE CONCEALED BRACKET FOR
FLOATING SHELF PROVIDE BACKING
AS REQ
WALL PER SCHEDULE
PLAM WRAPPED FLOATING
SHELF SEE ELEVATION
1 1/2"NOTE: SEE FINISH PLAN AND ELEVATIONS FOR FINISHES
LIGHT FIXTURE PER SCHEDULE
SEE ELEC
SEE RCP
TYP. CORNER BEAD
TYP. CONT. MTL. ANGLE PER STRUCTURAL
METAL STUDS W/5/8" GYP. BD.
TYPE " X" PER STRUCTURAL
MTL. BRACING PER
STRUCTURAL
LINE OF WALL BEYOND
WHERE OCCURS
1'-0"
CABINET
ANCHORAGE
LOWER CABINET REFER TO
ELEVATION
0'-3"
P.LAM ON 3/4" PLY. REFER TO
ELEVATIONS
COUNTERTOP - REFER TO
ELEVATIONS.
2'-0"
STRUCTURAL SHELF
ANCHORAGE 4 241/256"1 LAYER OF 5/8" GYP. PAINTED
PER FINISH SCHEDULE
REFER TO ELEVATION FOR DIMENSIONS0'-4"4"COUNTERTOP PER FINISH PLAN BASE TO MATCH MILLWORK FINISH4"3"
DOUG MOCKETT PULL DP3C-17S
MILLWORK CHASE
NOTE: SEE FINISH PLAN AND ELEVATIONS FOR FINISHES 1 1/2"OUTLET CUTOUT PER
EQUIP SPEC
MICROWAVE DRAWER PER
EQUIPMENT SCHEDULE VERIFY W/ EQUIP CLR15 1/2"13"PLAM FINISH PER
SCHEDULE
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
CASEWORK
DETAILS
A9.32
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 1" = 1'-0"01BREAK ROOM CASEWORK AND SOFFIT 1" = 1'-0"03MICROWAVE DRAWER
WALL TILE
PER
FINISH
PLAN
TILE FLOORING
PER FINISH PLAN
PAINTED
CEMENTITIOUS
BACKER BOARD PER
WALL TYPE
HORIZONTAL
& VERTICAL
GROUT
JOINTS TO
BE
1/16", SEE
NOTE: FOR JOINT ALIGNMENT DETAIL SEE
A9.41
07 A9.41
03 PARTITION PER PLAN
WALL TILE WHERE OCCURS
(SEE ELEVATION)
GRAB BAR COLLAR
ANCHOR
MOUNTING PLATE
TO BACKING
PLATE W/ 3 1/4"-#
12 S.M.S.0'-1 1/4"0'-1 1/2"
GRAB BAR WITH CONCEALED
MOUNTING SUPPORT
BACKING SUPPORT
24" MINCONTINUOUS ACOUSTICAL
SEALANT AROUND ENTIRE
PERIMETER TYP
24" MIN
TYP OUTLET BOX
BOX PAD, TYP
PARTITION PER PLAN
TYP SINGLE STUD PARTITION
WITH SOUND INSULATION
TYP DOUBLE STUD PARTITION WITH
SOUND INSULATION (SIMILAR FOR
STAGGERED STUDS)
NOTE: SEPARATE CONDUIT
FOR OUTLET BOXES ON 2
SIDES OF PARTITION. NO
CONTACT BETWEEN STUDS
1. 2.
3. 4.
5. 6.
NOTES:
PLACE OUTLET BOXES IN SEPARATE STUD SPACES.
BACK-TO-BACK OUTLETS NOT PERMITTED.
PLUG ALL UNUSED KNOCK-OUTS IN OUTLET BOXES WITH KNOCK OUT CAPS.
PROVIDE BACKING EQUIVALENT TO "LOWRY'S" OUTLET BOX PAD - (HARRY A. LOWRY & ASSOC. INC. @ 800/225-8231)
DEPTH OF OUTLET BOX MUST BE COMPATIBLE WITH STUD SIZE IN ORDER TO ACCOMMODATE BOX PAD.
ACOUSTICAL BOX PAD REQUIREMENT APPLIES TO ALL PARTITIONS WITH ACOUSTICAL INSULATION.0'-4"WALL FINISH AND
FRAMING PER PLANS
STRAIGHT RUBBER
BASE
WALL FINISH AND
FRAMING PER PLANS
STRAIGHT
RUBBER BASE
0'-4"A AT CONCRETE - UNO B AT CARPET, RUBBER &
WOOD FLOORING - UNO
SEE PLANS FOR
PARTITION TYPE
GROUT, TYP
WALL TILE PER FIN
PLAN AND INT
ELEVATIONS
B
SEE PLANS FOR
PARTITION TYPE
GROUT, TYP
WALL TILE PER FIN
PLAN AND INT
ELEVATIONS
A WALL FINISH PER FINISH PLAN
AND INTERIOR ELEVATIONS
SEE PLANS FOR
PARTITION TYPE
GROUT, TYP
WALL TILE PER FIN
PLAN AND INT
ELEVATIONS
D
SEE PLANS FOR
PARTITION TYPE
BULLNOSE CORNER
WALL TILE PER FIN
PLAN AND INT
ELEVATIONS
C
WALL FINISH, WHERE
OCCURS PER WALL TYPE
PARTITION, SEE FLOOR PLAN
FOR WALL TYPE DESIGNATION
CEMENTITIOUS BACKER
BOARD PER WALL TYPE
WALL TILE PER FINISH PLAN
THINSET ADHESIVE
0'-0 1/8"WALL TILE, SURFACE
BULLNOSE AT TOP
SEE ELEVATION
WALL, PARTITION TYPE PER
FLR PLAN
0'-6"COATED GLASS MAT WATER-
RESISTANT GYP BACKER BD
COVED BASE TRIM PIECE
FLR TILE PER FINISH PLAN
NOTE:
PROVIDE WP UNDER TILE
WORK, TYP SEE
SPECIFICATIONS
WALL TILE PER ELEVATIONS
ALIGN VERT JOINTS, TYP
WALL BASE PER FIN PLAN AND
INT ELEVATIONS
FLOOR TILE PER FIN PLANS
ALIGN JOINTS @ WALL & FLR,
TYP
0'-1 1/2"GRAB BAR
TOILET PARTITION
ALIGNALIGNPARTITION MOUNTED SEAT -
COVER DISPENSER, TOILET
TISSUE DISPENSER AND
SANITARY NAPKIN DISPOSAL
(WHERE OCCURS)
TYPICAL
STALL SIDE
ACCESSIBLE
STALL SIDE 0'-0 1/4"MAX"ROUTE OUT" PARTITION
TO ALLOW DISPENSER
FLANGE TO BE ALIGNED
WITH FACE OF PARTITIONALIGN 0'-1 1/2"
GRAB BAR
TILE WALL
ALIGNALIGNRECESSED SEAT-COVER
DISPENSER, TOILET TISSUE
DISPENSER AND SANITARY
NAPKIN DISPOSAL (WHERE
OCCURS)
1/4" GROUT JOINT MAX,
TYP ALL SIDES
TILE WALL
FLOOR DRAIN
1' - 0"1' - 0"FLOOR TILE PER FINISH PLANS -
SLOPE FULL TILE MODULES TO DRAIN
2% SLOPE, TYP.EQEQEQEQ
+0' - 0" A.F.F. AT 4 SIDES & CORNERS
-0' - 1/4" AT DRAIN
PLAN @ TILE
FLOOR DRAIN
1' - 0"1' - 0".
FLOOR FINISH PER FINISH PLANS
2% SLOPE, TYP.EQEQEQEQ
+0' - 0" A.F.F. AT 4 SIDES & CORNERS
PLAN @ EPOXY / RUBBER / FINISHED CONCRETE FLOOR
SECTION @ TILE
SECTION @ EPOXY / RUBBER / FINISHED CONCRETE FLOOR
FLOOR TILE PER FINISH PLAN
2% MAX. SLOPE2% MAX. SLOPEOPENINGS
1/4" MAX.
N.T.S.
SEALANT
S.S. FLOOR DRAIN
CONCRETE SLAB @ FIRST FLOOR;
CONCRETE DECKING @ UPPER FLOORS
FLOOR FINISH PER FINISH PLANS
2% MAX. SLOPE2% MAX. SLOPE
OPENINGS
1/4" MAX.
SEALANT
S.S. FLOOR DRAIN
CONCRETE SLAB @ FIRST FLOOR;
CONCRETE DECKING @ UPPER FLOORS
N.T.S.
2% SLOPE, TYP.
2"X1" STEEL BAR STOCK
ELEVATION VIEW
4'-0" O.C. MAX
26" (27" MAX)CONCRETE FLOOR
SECTION VIEW
F.O.F.
0'-1"
FINISHED WALL
NOTE:
UNDERCUT ALL DOORS TO
CLEAR FLOOR FINISH BY 1/4"
EXCEPT AT RATED DOORS.
SEALED CONCRETE OR
POLISHED CONCRETE
CENTER LINE OF
THRESHOLD & FRAME
CONCRETE SLAB
SOLID SURFACING
THRESHOLD (COLOR BY
ARCHITECT) 1:2 MAX.
SLOPE, TYP.
SEALED CONCRETE OR
POLISHED CONCRETE
DOOR WHERE OCCURS
1/4" MAXEDGE OF DOOR FRAME
BEYOND
BSEALED OR POLISHED CONCRETE / EPOXY
CENTER LINE OF THRESHOLD & FRAME
DOOR, WHERE
OCCURS
CARPET
CONCRETE SLAB
ACARPET / CONCRETE
2:1 MAX. SLOPE
CONCRETE
FLOOR PER
FINISH PLAN
BURKE MERCER #700
REDUCER, COLOR TO
MATCH ADJ. WALL
BASE
0'-0 1/4"MAX1/2" MAX1/4" MAX1
2MAX
DOOR, WHERE OCCURS
POLISHED CONCRETE / TILE
TILE PER FINISH
PLAN
2:1 MAX. SLOPE
1 2MAX.
SOLID SURFACE
TRANSITION: CORIAN
POLISHED CONCRETE
FLOOR PER FINISH PLAN
1/2"MAX1/4"MAXDOOR, WHERE OCCURS
STATIC DISSIPATIVE TILE,
REFER TO FINISH PLAN
CONCRETE SLAB
STATIC DISSIPATIVE TILE / CONCRETE OR EPOXY
JOHNSONITE SSR-XX-B 1/8" TO 0"
WHEELED TRAFFIC TRANSITION,
COLOR: CHARCOAL #20
CONCRETE OR
EPOXY FLOOR PER
FINISH PLAN
2:1 MAX. SLOPE
12MAX.
CENTER LINE OF
THRESHOLD AND FRAME
C
D
CENTER LINE OF
THRESHOLD AND FRAME
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 As indicatedCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
INTERIOR DETAILS
A9.41
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 1/2" = 1'-0" A9.41 08BASE TO WAINSCOT
3" = 1'-0"
A9.41 06GRAB BAR AND SUPPORT
1 1/2" = 1'-0"
A9.4113OUTLET BOX DETAILS 3" = 1'-0"
A9.41 01RUBBER BASE
3" = 1'-0"
A9.41 07TILE CORNERS 3" = 1'-0"
A9.41 03HORIZONTAL TILE JOINT
3" = 1'-0"
A9.41 02TILE AT TOP AND BASE
1 : 6
A9.41 04TILE CORNERS ISOMETRIC
3" = 1'-0"
A9.41 09PARTITION MOUNTED ACCESSORY 3" = 1'-0"
A9.41 05RECESSED TOILET ACCESSORY
3" = 1'-0"19FLOOR DRAIN DETAILS
3" = 1'-0"12CANE DETECTION RAIL
3" = 1'-0"10INTERIOR FLOOR TRANSITIONS
WPWPWPWPWPWPWPWPWPTVFFFFFF
F
FF
FFFJ
JJJJFJJFF
FFJJFJJJWP
J
F
FF
FF
J
GMWJTTJJJJJ
JJJJJ
T
FC-1
T
FC-2
Z
VFC-1
Z
VFC-2
DCDC
DCWVLTCVLTSS
S
SCMMWREF.TVTVN 1792873.09E 6520967.53CGPRINT
COLUMBIA WAYPROPERTY LINELIMIT OF WORKPROPOSED
2 STORY BUILDING
PROPOSED 1
STORY
CLASSROOMS
CONGRESSMAN STEVE HORN WAY
PROPERTY LINELIMIT OF WORKROOF ABOVE
E-G
003
E-E
001
E-F
002
E-G
004
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1" = 20'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SIGNAGE SITE PLAN
SG1.01
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 1" = 20'-0"1SITE PLAN
FF
FFFF
FFF
FF
CMMWREF.TVTVCGPRINT
EXHIBIT
SPACE
100
ELEVATOR
111
ELEVATOR
MACHINE
ROOM
110
STAFF
ROOM
102
STORAGE
101
JANITOR'S
ROOM
109
FAMILY
RESTROOM
108
STAFF
RESTROOM
114
WOMEN'S
RESTROOM
107
IDF
ROOM
105
ELECTRICAL
ROOM
104
MEN'S
RESTROOM
106
MECHANICAL
ROOM
103
STEM
CLASSROOM
112
STEM
CLASSROOM
113
FIRE
RISER
115
ROOF ABOVE
I-A2
1005
I-B2
1004
I-A1
1001 I-B1
1000
I-C
1003
I-C
1016
I-C
1009
I-A3
1007
I-B3
1006
I-H
1017
I-C
1012
I-C
1013
I-C
1010
I-C
1023
I-C
1022
I-C
1021
I-C
1020
I-C
1019
I-C
1018
I-C
1025
I-C
1026
I-A3
1014
I-B3
1015
I-G
1011
I-C
1024
I-H
1027
I-C
1028 I-C
1029
I-C
1030
I-C
1031
I-F1
1037
I-F1
1034
I-F1
1035
I-F1
1036
I-F1
1032
I-F1
1033
I-C
1038
I-P2
1039
I-P2
1041
I-P1
1042
I-P1
1043
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
FIRST FLOOR
SIGNAGE PLAN
SG2.01
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 1/8" = 1'-0"01FIRST FLOOR SIGNAGE PLAN
I-G
2000
I-C
2003
I-P1
2001
I-Q
2002
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SECOND FLOOR
SIGNAGE PLAN
SG2.02
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 1/8" = 1'-0"1SECOND FLOOR SIGNAGE PLAN
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN07/18/2022DESIGN DEVELOPMENT 10/27/2022ENTER DESCRIPTION XX/XX/XXXXENTER DESCRIPTION XX/XX/XXXXENTER DESCRIPTION XX/XX/XXXXCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SIGNAGE
SCHEDULE
SG3.01
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGSIGN SCHEDULE - BUILDING FIRST FLOOR SIGN
NUMBER
SIGN
TYPE SIGN DETAIL COPY
MOUNT
LOCATION BRAILLE
1000 I-B1 (07/SG4.01)(MEN'S - SEE DETAIL FOR ARTWORK/COPY LAYOUT)WALL Yes 1001 I-A1 (06/SG4.01)(MEN'S - SEE DETAIL FOR ARTWORK/COPY LAYOUT)DOOR No 1003 I-C (11/SG4.01)JANITOR'S ROOM WALL Yes
1004 I-B2 (08/SG4.01)(WOMEN'S - SEE DETAIL FOR ARTWORK/COPY LAYOUT)WALL Yes 1005 I-A2 (06/SG4.01)(WOMEN'S - SEE DETAIL FOR ARTWORK/COPY LAYOUT)DOOR No 1006 I-B3 (07/SG4.01)(RESTROOM - SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL Yes 1007 I-A3 (07/SG4.01)(RESTROOM - SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1009 I-C (11/SG4.01)NURSING ROOM WALL Yes
1010 I-C (11/SG4.01)STORAGE WALL Yes
1011 I-G (07/SG4.02)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1012 I-C (11/SG4.01)ELEVATOR MACHINE ROOM WALL Yes
1013 I-C (11/SG4.01)STAFF ROOM WALL Yes
1014 I-A3 (07/SG4.01)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1015 I-B3 (07/SG4.01)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL Yes 1016 I-C (11/SG4.01)IDF ROOM WALL Yes
1017 I-H (17/SG4.01)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1018 I-C (11/SG4.01)FIRE RISER ROOM WALL Yes
1019 I-C (11/SG4.01)STAFF ROOM WALL Yes
1020 I-C (11/SG4.01)STORAGE WALL Yes
1021 I-C (11/SG4.01)MECHANICAL ROOM WALL Yes
1022 I-C (11/SG4.01)ELECTRICAL ROOM WALL Yes
1023 I-C (11/SG4.01)EXHIBIT SPACE WALL Yes
1024 I-C (11/SG4.01)EXIT ROUTE WALL Yes
1025 I-C (11/SG4.01)STEM ROOM WALL Yes
1026 I-C (11/SG4.01)STEM ROOM WALL Yes
1027 I-H (17/SG4.01)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1028 I-C (11/SG4.01)EXIT WALL Yes
1029 I-C (11/SG4.01)EXIT WALL Yes
1030 I-C (11/SG4.01)EXIT WALL Yes
1031 I-C (11/SG4.01)EXIT WALL Yes
1032 I-F1 (19/SG4.01)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1033 I-F1 (19/SG4.01)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1034 I-F1 (19/SG4.01)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1035 I-F1 (19/SG4.01)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1036 I-F1 (19/SG4.01)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1037 I-F1 (19/SG4.01)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1038 I-C (11/SG4.01)STEM ROOM WALL Yes
1039 I-P2 (16/SG4.01)IN OPEN POSITION 71, IN CLOSED POSITION 38 (SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1041 I-P2 (16/SG4.01)IN OPEN POSITION 71, IN CLOSED POSITION 33 (SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1042 I-P1 (12/SG4.01)299 (SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 1043 I-P1 (12/SG4.01)299 (SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No
SIGN SCHEDULE - SITE
SIGN
NUMBER
SIGN
TYPE SIGN DETAIL COPY
MOUNT
LOCATION BRAILLE
001 E-E (05/SG4.02)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 002 E-F (06/SG4.02)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 003 E-G (14/SG4.02)(0000A - SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 004 E-G (14/SG4.02)(0000B - SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No
SIGN SCHEDULE - BUILDING SECOND FLOOR
SIGN
NUMBER
SIGN
TYPE SIGN DETAIL COPY
MOUNT
LOCATION BRAILLE
2000 I-G (07/SG4.02)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 2001 I-P1 (12/SG4.01)(211 - SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 2002 I-Q (15/SG4.02)(SEE DETAL FOR ARTWORK/COPY LAYOUT)WALL No 2003 I-C (11/SG4.01)ROOF ACCESS WALL Yes
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
11. 12.
13. 14.
THE SIGN CONTRACTOR SHALL CONFIRM AND PROVIDE ALL CODE
COMPLIANT SIGNAGE.
PRIOR TO FABRICATION, THE SIGN CONTRACTOR SHALL PROVIDE
SHOP DRAWINGS WITH THE GRAPHIC LAYOUT, COPY, AND BRAILLE (WHERE OCCURS) FOR ALL SIGN TYPES FOR REVIEW BY THE OWNER AND THE ARCHITECT.
ALL CONSTRUCTION ATTACHMENT / CONSTRUCTION METHODS TO BE HIDDEN.
ALL SIGNAGE MOUNTING SYSTEMS / BRACKETS TO BE HIDDEN, U.N.O.
ON DETAIL.
PROVIDE ACCESS FOR INTERNAL MAINTENANCE OF LIGHTS FOR ALL INTERNALLY ILLUMINATED SIGN TYPES.
PRIOR TO FABRICATION, THE SIGN CONTRACTOR SHALL PROVIDE A
DRAWING WITH THE GRAPHIC LAYOUT, COPY, AND BRAILLE (WHERE
OCCURS) FOR ALL SIGNS FOR REVIEW BY THE OWNER AND THE
ARCHITECT. IDENTIFY EACH SIGN WITH ITS TAG AS IDENTIFIED ON THE FOLLOWING SHEETS: SG1.01, SG2.01, SG2.02, SG3.01, SG 4.01, SG4.02
THE SIGN CONTRACTOR SHALL BE RESPONSIBLE FOR THE PURCHASE OF ALL REQUIRED FONT TYPES.
ALL ARTWORK TO BE COMPLETED BY THE SIGN CONTRACTOR FOR
REVIEW BY THE OWNER AND THE ARCHITECT, UNLESS NOTED
OTHERWISE ON DETAIL.
ALL EXTERIOR SIGNS TO HAVE UV AND ANTI GRAFFITI COATING
COMPRISED OF NAN-SIZED QUARTZ PARTICLES COVALENTLY BONDED TO SUBSTRATE APPLIED OVER ALL COPY AND GRAPHICS, U.N.O. ON DETAIL.
ALL LIGHTING TO BE (LED) UNLESS NOTED ON DETAIL, COLOR
TEMPERATURE 3000K
PRIOR TO FABRICATION, THE CONTRACTOR SHALL PROVIDE COLOR
SAMPLES APPLIED TO THE APPROPRIATE SUBSTRATE FOR ALL
COLORS.
PRIOR TO FABRICATION, THE SIGN CONTRACTOR SHALL PROVIDE TWO (2) MOCK-UPS WHERE REQUESTED PER DETAIL, ONE (1) MOCK-UP WILL BE RETURNED TO CONTRACTOR AND ONE (1) MOCK-UP WILL BE
RETAINED BY ARCHITECT.
ALL TACTILE SIGNS TO HAVE EASED CORNERS.
ALL BRAILLE SHOWN IN DETAIL LAYOUTS ARE PLACE HOLDER ONLY, PROVIDE CORRECT TRANSLATION AS REQUIRED.
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
SIGNS SHALL COMPLY WITH SECTION CBC 11B-703, WHERE BOTH VISUAL AND TACTILE CHARACTERS ARE REQUIRED.
RAISED CHARACTERS SHALL COMPLY WITH CBC 11B-703.2 AND SHALL BE DUPLICATED IN BRAILLE COMPLYING WITH SECTION CBC 11B-703.3.
CHARACTER DEPTH: CBC 11B-703.2.1
CHARACTER CASE: CBC 11B-703.2.2
CHARACTER STYLE: CBC 11B-703.2.3
CHARACTER PROPORTIONS: CBC 11B-703.2.4
CHARACTER HEIGHT: CBC 11B-703.2.5
CHARACTER STROKE THICKNESS: CBC 11B-703.2.6
CHARACTER SPACING: CBC 11B-703.2.7
CHARACTER LINE SPACING: CBC 11B-703.2.8
CHARACTER FORMAT: CBC 11B-703.2.9
BRAILLE CHARACTERS SHALL COMPLY WITH CBC 11B-703.3
BRAILLE SHALL BE CONTRACTED (GRADE 2) AND SHALL COMPLY WITH SECTIONS CBC11B-703.3 AND CBC 11B-703.4.
BRAILLE DIMENSIONS AND CAPITALIZATION: CBC TABLE 11B-703.3.1 BRAILLE POSITION: CBC TABLE 11B-703.3.2
VISUAL CHARACTERS SHALL COMPLY WITH CBC 11B-703.5
FINISH AND CONTRAST: CBC11B-703.5.1
HEIGHT: CBC TABLE 11B-703-5.5
STROKE THICKNESS: CBC11B-703.5.7
FORMAT: CBC TABLE 11B-703.5.10
SIGNS AT SINGLE DOORS
GLASS
SIGN ON
BOTH SIDES
1. 2.
3. 4.
NOTES:
SIGN MOUNTING LOCATION AND HEIGHT SHALL COMPLY WITH CBC 11B-703.4.1; CBC 11B-703.4.2; CBC 11B-703.7.2.6
AT SINGLE DOORS, LOCATE SIGN ON LATCH SIDE OUTSIDE OF DOOR ENTERING ROOM THAT IS IDENTIFIED ON SIGN
WHEN SIGNS ARE MOUNTED TO GLASS, PROVIDE VINYL BACKING BETWEEN SIGN AND GLASS
WHEN SIGNS ARE MOUNTED ON BOTH SIDES OF GLASS, ALIGN SIGNS CL
(58" MIN. - 60" MAX.)60" A.F.F.EQ EQCL
RAISED COPY
LOWEST BRAILLE CELLS48" MIN. BASELINE OFHIGHEST RAISED CHARACTERS60" MAX BASELINE OFEQ EQ FLR. SPACE
1'-6"
RESTROOM DOOR SIGNAGE
RESTROOM & TACTILE SIGN
RAISED COPY
LOWEST BRAILLE CELLS48" MIN. BASELINE OFEQ EQ
FLR. SPACE
1'-6"HIGHEST RAISED CHARACTERS60" MAX BASELINE OFSIGNS AT DOUBLE DOORSSIGNS MOUNTED TO GLASS
SIGN ON
SINGLE SIDE
GLASS
VINYL, SAME SIZE AND
SHAPE AS SIGN -
COLOR (V1)
STANDARD COLORS
(P1) = MATTEWS PINT - (MP04761 'STEEL WOOL')
(P2) = MATTEWS PINT - (MP27386 'VERIZON WHITE')
VINYL COLORS
(V1) = 3M OPAQUE GRAPHIC FILM - (180MC-10 WHITE)
FONT TYPES
(A) = ARIAL
(B) = TBD
1. 2.
NOTES:
SEE DETAIL 01/SG4.01 FOR FOTNT TYPES AND COLORS
VERTICES SHALL BE RADIUSED BETWEEN 1/8" MIN. AND 1/4" MAX. (I-A1) MEN
(I-A2) WOMEN
(I-A3) RESTROOM
1/4" THICK ACRYLIC EQUILATERAL
TRIANGLE SIGN PANEL POINTING
UPWARDS WITH 12" SIDES - COLOR
(P2)
DIRECT PRINT - COLOR (P1)
DIRECT PRINT - COLOR (P1)
1/4" THICK ACRYLIC 12" DIAMETER
CIRCLE SIGN PANEL - COLOR (P2)
1/4" THICK ACRYLIC EQUILATERAL
TRIANGLE SIGN PANEL POINTING
UPWARDS, SUPER IMPOSED ON
AND GEOMETRICALLY INSCRIBED
WITHIN THE CIRCLE. THE VERTICES
OF THE TRIANGLE SHALL BE
LOCATED ON THE EDGE OF THE
CIRCLE - COLOR (P1)
1. 2.
NOTES:
VINYL APPLIED TO SECOND SURFACE OF GLASS
VYNYL APPLIED TO FIRST SURFACE OF NON GLASS SURFACE
WHERE OCCURS
NO SMOKING OR VAPING
WITHIN 25 FEET OF
BUILDING ENTRANCE0'-0 1/2"5/8" TALL COPY, FONT TYPE
(C) - COLOR (V1)0'-3"PICTOGRAM - COLOR (V1)
DIRECT TO SUBSTRATE
DIGITAL PRINT SIGN COPY
AND GRAPHIC - COLOR (P1)
5'-10" MAX
A.F.F.
ASSISTIVE LISTENING
SYSTEMS AVAILABLE
AT RECEPTION DESK
3/32" THICK
ALUMINUM
PANEL -
COLOR
(P2)0'-6"1'-2"
5/8" TALL COPY, FONT TYPE (B)0'-0 1/2"0'-0 1/2"0'-0 1/2"0'-0 1/2" DESIGNER'S NOTE:
SHOW WHERE TO OBTAIN THE
SYSTEM.
IF SYSTEM IS LOCATED IN THE
SAME ROOM, REMOVE SAMPLE
COPY "AT RECEPTION DESK"
1. NOTES:
SEE DETAIL 01/SG4.01 FOR FOTNT TYPES AND COLORS
MAXIMUM
OCCUPANCY
###0'-6"1'-2"
5/8" TALL RAISED LETTERS,
FONT TYPE (A) - COLOR (P1)
1/4" THICK CLEAR ACRYLIC
PANEL - COLOR (P2)
APPLIED TO SECOND
SURFACE.
5'-10" MAX.
A.F.F.
1. NOTES:
SEE DETAIL 01/SG4.01 FOR FOTNT TYPES AND COLORS
5'-10" MAX.
A.F.F.
MAXIMUM OCCUPANCY
0'-8"1'-2"
1. NOTES:
SEE DETAIL 01/SG4.01 FOR FOTNT TYPES AND COLORS
5/8" TALL RAISED LETTERS,
FONT TYPE (A) - COLOR (P1)
1/4" THICK CLEAR ACRYLIC
PANEL - COLOR (P2)
APPLIED TO SECOND
SURFACE.
IN OPEN
POSITION
###
IN CLOSED
POSITION
###0'-0 3/4"1/8" THICK LINE -
COLOR (P1)0'-0 3/4"0'-1 1/2"1/4" THICK CLEAR ACRYLIC
PANEL
5/8" TALL RAISED LETTERS,
FONT TYPE (A) - COLOR (P1)
PICTOGRAM APPLIED TO
SECOND SURFACE - COLOR
(P1), FIELD COLOR (P2)
0'-8"0'-0 3/8"5'-0"
A.F.F.0'-8"MEN
0'-2"0'-5"0'-0 1/2"BRAILLE, COLOR (CLEAR)
(I-B1) FRONT ELEVATION
5/8" TALL RAISED LETTERS,
FONT TYPE (A) - COLOR (P1)
0'-8"0'-0 3/8"5'-0"
A.F.F.0'-8"WOMEN
0'-2"0'-0 1/2"0'-5"1/4" THICK CLEAR ACRYLIC
PANEL
PICTOGRAM APPLIED TO
SECOND SURFACE - COLOR
(P1), FIELD COLOR (P2)
BRAILLE, COLOR (CLEAR)
(I-B2) FRONT ELEVATION
1/4" THICK CLEAR ACRYLIC
PANEL
5/8" TALL RAISED LETTERS,
FONT TYPE (A) - COLOR (P1)
PICTOGRAM APPLIED TO
SECOND SURFACE - COLOR
(P1), FIELD COLOR (P2)
BRAILLE, COLOR (CLEAR)
(I-B3) FRONT ELEVATION
0'-8"0'-0 3/8"5'-0"
A.F.F.0'-8"RESTROOM
0'-2"EQ.0'-4" EQ.
1. NOTES:
SEE DETAIL 01/SG4.01 FOR FOTNT TYPES AND COLORS
NO SMOKING OR VAPING WITHIN 25 FEET OF BUILDING ENTRANCE 0'-11"2'-4"0'-8"
5'-0"
A.F.F.
ELEVATOR
MACHINE
ROOM
FRONT ELEVATION
(THREE LINE COPY)
1/4" THICK CLEAR ACRYLIC
PANEL - COLOR (P2)
APPLIED TO SECOND
SURFACE. AT EXTERIOR
CONDITIONS, FINISH TO BE
ALUMINUM, WITH COLORS
APPLIED TO TO FIRST
SURFACE.0'-0 3/8"EXIT
FRONT ELEVATION
(SINGLE LINE COPY)EQ.EQ.COPY SHALL NOT
ENCROACH ON IMAGINARY
1/2" BORDER AROUND SIGN
PANEL0'-0 1/2"0'-0 1/2"EQ.EQ.0'-0 3/8"0'-5 1/4"5'-0"
A.F.F.
0'-8"
0'-0 1/2"0'-0 1/2"BRAILLE, COLOR (CLEAR)
0'-8"
5'-0"
A.F.F.
EXIT STAIR
DOWN
FRONT ELEVATION
(TWO LINE COPY)EQ.EQ.0'-0 3/8"0'-4 1/2"0'-0 1/2"0'-0 1/2"0'-4"1.
NOTES:
SEE DETAIL 01/SG4.01 FOR FOTNT TYPES AND COLORS
5/8" TALL RAISED LETTERS.
FONT TYPE (A) - COLOR (P1)
WALL
8'-0"
A.F.F.
FRONT ELEVATION
PLAN
6"4 1/2"PERFORATED METAL
CHASIS
1/4" THICK CLEAR ACRYLIC
PANEL - COLOR (P2)
APPLIED TO SECOND
SURFACE.
1/4" THICK CLEAR ACRYLIC
PANEL - COLOR (P2)
APPLIED TO SECOND
SURFACE.
PICTOGRAM APPLIED TO
SECOND SURFACE - COLOR
(P1), FIELD COLOR (P2)
1. 2.
3. NOTES:
SEE DETAIL 01/SG4.01 FOR FOTNT TYPES AND COLORS
GRAPHIC CENTER ON SIGN PANEL
SEE SCHEDULE FOR ARROW DIRECTION
WALL
8'-0"
A.F.F.
FRONT ELEVATION
PLAN
6"4 1/2"1.
2. 3.
NOTES:
SEE DETAIL 01/SG4.01 FOR FOTNT TYPES AND COLORS
GRAPHIC CENTER ON SIGN PANEL
SEE SCHEDULE FOR ARROW DIRECTION
METAL MOUNTING BRACKET
1/4" THICK CLEAR ACRYLIC
PANEL - COLOR (P2)
APPLIED TO SECOND
SURFACE.
1/4" THICK CLEAR ACRYLIC
PANEL - COLOR (P2)
APPLIED TO SECOND
SURFACE.
PICTOGRAM APPLIED TO
SECOND SURFACE - COLOR
(P1), FIELD COLOR (P2)
1"
8'-0"
A.F.F.
BACK ELEVATION
1/4" THICK CLEAR ACRYLIC
PANEL - COLOR (P2)
APPLIED TO SECOND
SURFACE.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 As indicatedCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SIGNAGE DETAILS
SG4.01
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGSIGN GENERAL NOTES
SIGN RAISED CHARACTER & BRAILLE NOTES
NTS 05SIGN MOUNTING 12" = 1'-0"01SIGN COLORS AND FONT TYPES NTS 06SIGN TYPE I-A (DOOR)
3" = 1'-0"17SIGN TYPE I-H (ENTRY SYMBOLS)
10SIGN TYPE I-F (ASSISTIVE LISTENING)
12SIGN TYPE I-P1 (MAXIMUM OCCUPANCY)16SIGN TYPE I-P2 (MAXIMUM OCCUPANCY/DIVISIBLE) 07SIGN TYPE I-B (WALL) 3" = 1'-0"11SIGN TYPE I-C 3" = 1'-0"19SIGN TYPE I-F1 (FIRE EXT.) 3" = 1'-0"23SIGN TYPE I-F2 (FIRE EXT.)
18" TALL X 3" DEEP LED HALO LIT
FABRICATED ALUMINUM COPY, PIN
MOUNTED 1 1/2" AWAY FROM FROM
MOUNTINGSURFACE. FONT TYPE (B), (P2).
INSULATED METAL PANEL BY OTHERS
1. 2.
NOTES:
SEE DETAIL 01/SG4.01 FOR FONT TYPES AND COLORS
LED COLOR TEMPERATURE (CONFIRM WITH LIGHTING)
1. 2.
NOTES:
SEE DETAIL 01/SG4.01 FOR FONT TYPES AND COLORS
LED COLOR TEMPERATURE (CONFIRM WITH LIGHTING)
4.24.8 10
SG4.02
2'-6" TALL, 4" DEEP FABRICATED
ALUMINUM COPY, LED INTERNALLY
ILLUMINATED FACE-LIT CHANNEL
COPY, TRANSLUCENT WHITE FACE,
FONT TYPE (B), PAINT ALL SIDES
OF ALUMINUM (P-TBD)
FASCIA BY OTHERS
INSULATED
METAL PANEL
BY OTHERS0'-10"1'-0"
FLOOR 2
3'-6" A.F.F.0'-8"FIREFIGHTERS OPERATION
FIRE RECALL
To recall elevators
Insert fire key and
turn to "ON"
IN CASE OF FIRE,
USE STAIRWAYS FOR EXIT.
DO NOT USE ELEVATOR.
4'-0" A.F.F.
MAX HEIGHT OF BOTTOM PORTION
OF EVACUATION SIGN
0'-2"EVACUATION INFORMATION1'-0"0'-2" 0'-3"
EQ
EVACUATION INFORMATION
0'-11"EQ
3'-0"1'-0"
1" TALL ETCHED
PAINT FILLED COPY
FINAL EVACUATION
COPY/GRAPHIC TO BE
PROVIDED BY SIGN
FABRICATOR FOR
ARCHITECT/OWNER
REVIEW, ETCHED AND
PAINT FILL
1/2" TALL ETCHED
PAINT FILLED COPY
ELEVATOR
DISPATCH SYSTEM
PER ELEVATOR
SPECIFICATIONS
1/4" TALL ETCHED
AND PAINT FILLED
COPY (AT FIRST
FLOOR ONLY)
1/4" TALL ETCHED
AND PAINT FILLED
COPY (AT FIRST
FLOOR ONLY)
FIREFIGHTERS'
PHONE JACK (AT
FIRST FLOOR ONLY)
SPEAKER
1. 2.
NOTES:
SEE DETAIL 01/SG4.01 FOR FONT TYPES AND COLORS
COORDINATE SIGN PANEL FACE LAYOUT WITH ELEVATOR CONTRACTOR
FRONT ELEVATION (HORIZONTAL PLAN LAYOUT)
3/32" THICK ALUMINUM SIGN
PANEL PAINTED - COLOR (P2)PUSH FOR HELP
AREA OF RECESSED 2-WAY
COMMUNICATION DEVICE
MOUNTED TO BACK OF SIGN
PANEL, COORDINATE PANEL
FACE LAYOUT WITH 2-WAY
COMMUNICATION DEVICE
5/8" TALL RAISED COPY,
FONT TYPE (A), COLOR (P1)
COPY SHALL NOT ENCROACH
ON IMAGINARY 1/2" BORDER
AROUND PERIMETER OF
SIGN PANEL
Persons able to use the exit
stairway do so as soon as possible,
unless they are assisting others.
After activation the two-way
emergency communication system,
wait here for assistance.
SOLID LIGHT:
CALLING
BLINKING LIGHT:
RECEIVED
BRAILLE
DIRECT PRINT 5/8" TALL
COPY, FONT TYPE (A),
COLOR (P1)0'-10"1'-8"
3'-4" A.F.F.
BOTTOM OF SIGN PANEL
1. 2.
NOTES:
SEE DETAIL 01/SG4.01 FOR FONT TYPES AND COLORS
LED COLOR TEMPERATURE (CONFIRM WITH LIGHTING)
B.1B.11'-0" TALL, 3" DEEP LED HALO
LIT FABRICATED ALUMINUM
COPY, PIN MOUNTED 1 1/2"
AWAY FROM FROM
MOUNTINGSURFACE. FONT
TYPE (B), (P2).
1. 2.
NOTES:
SEE DETAIL 01/SG4.01 FOR FONT TYPES AND COLORS
LED COLOR TEMPERATURE (CONFIRM WITH LIGHTING)
EQEQ
EQEQG
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 As indicatedCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SIGNAGE DETAILS
SG4.02
03/20/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 1/4" = 1'-0"05E-E (STEM BUILDING SIGN 1) 1/4" = 1'-0"06E-F (STEM BUILDING SIGN 2)
3" = 1'-0"07I-G (EVACUATION MAP/CALL BUTTON) 3" = 1'-0"15I-Q (2-WAY COMMUNICATION SYSTEM) 1/4" = 1'-0"14E-G (EXHIBIT BUILDING SIGN 3)
ANY APPLIANCE FOR WHICH THERE IS A CALIFORNIA
STANDARD ESTABLISHED IN THE APPLIANCE EFFICIENCY
REGULATIONS SHALL COMPLY WITH THE APPLIANCE
STANDARD.
COVERED PROCESS
REFRIGERATED WAREHOUSES, COMMERCIAL
REFRIGERATION, ENCLOSED PARKING GARAGES, PROCESS
BOILERS, AND COMPRESSED AIR SYSTEMS SHALL MEET THE
REQUIREMENTS WITHIN THIS SECTION.
BUILDING COMMISSIONING
PROCEDURES, REVIEWS, AND REPORTS SHALL BE FOLLOWED
AS DESCRIBED WITHIN THIS SECTION.
EQUIPMENT EFFICIENCY
HEATING AND COOLING EQUIPMENT EFFICIENCY
ANY SPACE-CONDITIONING EQUIPMENT SHALL BE INSTALLED
ONLY IF THE MANUFACTURER HAS CERTIFIED THAT THE
EQUIPMENT COMPLIES WITH ALL THE APPLICABLE
REQUIREMENTS OF THE CALIFORNIA BUILDING ENERGY
EFFICIENCY STANDARDS.
PIPE INSULATION
ALL HVAC PIPING, EXCEPT FOR THAT CONVEYING LIQUIDS
BETWEEN 40°F AND 350°F OR LOCATED WITHIN HVAC
EQUIPMENT, SHALL BE INSULATED IN ACCORDANCE WITHIN
THIS SECTION.
WATER HEATER CERTIFICATION
ANY SERVICE WATER-HEATING SYSTEM OR EQUIPMENT MAY
BE INSTALLED ONLY IF THE MANUFACTURER HAS CERTIFIED
THAT THE SYSTEM OR EQUIPMENT COMPLIES WITH ALL OF
THE REQUIREMENTS OF THE CALIFORNIA BUILDING ENERGY
EFFICIENCY STANDARDS.
SERVICE WATER HEATING INSTALLATION
ON SYSTEMS THAT HAVE A TOTAL CAPACITY GREATER THAN
167,000 BTU/HR. OUTLETS THAT REQUIRE HIGHER SERVICE
WATER TEMPERATURES SHALL HAVE SEPARATE REMOTE
HEATERS, HEAT EXCHANGERS, OR BOOSTERS. CIRCULATING
SERVICE WATER-HEATING SYSTEMS SHALL HAVE A CONTROL
CAPABLE OF AUTOMATICALLY TURNING OFF THE
CIRCULATING PUMP WHEN HOT WATER IS NOT REQUIRED.
CONTROLS SHALL LIMIT THE OUTLET TEMPERATURE TO 110°F
FOR PUBLIC LAVATORIES.
POOL AND SPA EFFICIENCY AND CONTROL
A READILY ACCESSIBLE ON-OFF SWITCH, MOUNTED ON THE
OUTSIDE OF THE HEATER THAT ALLOWS SHUTTING OFF THE
HEATER WITHOUT ADJUSTING THE THERMOSTAT SETTING; A
PERMANENT, EASILY READABLE, AND WEATHERPROOF PLATE
OR CARD THAT GIVES INSTRUCTION FOR THE ENERGY
EFFICIENT OPERATION OF THE POOL OR SPA AND FOR THE
PROPER CARE OF POOL OR SPA WATER WHEN A COVER IS
USED. NO ELECTRIC RESISTANCE HEATING.
POOL AND SPA INSTALLATION
ANY POOL OR SPA HEATING SYSTEM OR EQUIPMENT SHALL
BE INSTALLED WITH ALL OF THE FOLLOWING: AT LEAST 36
INCHES OF PIPE BETWEEN THE FILTER AND THE HEATER TO
ALLOW FOR THE FUTURE ADDITION OF SOLAR HEATING
EQUIPMENT; A COVER FOR OUTDOOR POOLS OR OUTDOOR
SPAS; THE POOL SHALL HAVE DIRECTIONAL INLETS THAT
ADEQUATELY MIX THE POOL WATER; THE CIRCULATION PUMP
SHALL HAVE A TIME SWITCH THAT ALLOWS THE PUMP TO BE
SET TO RUN IN THE OFF-PEAK ELECTRIC DEMAND PERIOD.
POOL HEATERS SHALL NOT HAVE A PILOT LIGHT.
SPA HEATERS SHALL NOT HAVE A PILOT LIGHT.
GENERAL
WATER-SIDE SYSTEMS
SERVICE HOT WATER SYSTEMS
110.1
120.6
120.8
110.2(d)
120.1(c.2)
120.1(d.1)
120.1(d.2)
120.1(d.3)
120.2(e.1)
120.2(e.2)
120.2(f)
120.2(g)
120.2(i)
120.4
110.2(a)
120.3
110.3(a)
110.3(b)
110.3(c)
110.4(a)
110.4(b)
110.5(c)
110.5(d)
AIR-SIDE SYSTEMS
HEATING AND COOLING EQUIPMENT EFFICIENCY
ANY SPACE-CONDITIONING EQUIPMENT SHALL BE INSTALLED
ONLY IF THE MANUFACTURER HAS CERTIFIED THAT THE
EQUIPMENT COMPLIES WITH ALL THE APPLICABLE
REQUIREMENTS OF THE CALIFORNIA BUILDING ENERGY
EFFICIENCY STANDARDS.
HEAT PUMP CONTROLS
HEAT PUMPS WITH SUPPLEMENTARY ELECTRIC RESISTANCE
HEATERS SHALL HAVE CONTROLS: 1. THAT PREVENT
SUPPLEMENTARY HEATER OPERATION WHEN THE HEATING
LOAD CAN BE MET BY THE HEAT PUMP ALONE; AND 2. IN
WHICH THE CUT-ON TEMPERATURE FOR COMPRESSION
HEATING IS HIGHER THAN THE CUT-ON TEMPERATURE FOR
SUPPLEMENTARY HEATING, AND THE CUT-OFF
TEMPERATURE FOR COMPRESSION HEATING IS HIGHER THAN
THE CUT-OFF TEMPERATURE FOR SUPPLEMENTARY
HEATING.
THERMOSTATS
ALL UNITARY HEATING OR COOLING SYSTEMS, INCLUDING
HEAT PUMPS, NOT CONTROLLED BY A CENTRAL ENERGY
MANAGEMENT SYSTEM SHALL HAVE A SETBACK
THERMOSTAT.
FURNACE CONTROLS
GAS-FIRED AND OIL-FIRED FORCED AIR FURNACES WITH
INPUT RATINGS 225,000 BTU/H SHALL NOT HAVE A PILOT
LIGHT, AND SHALL HAVE EITHER POWER VENTING OR A FLUE
DAMPER.
NATURAL VENTILATION
NATURALLY VENTILATED SPACES SHALL BE PERMANENTLY
OPEN TO AND WITHIN 20 FEET OF OPERABLE WALL OR ROOF
OPENINGS TO THE OUTDOORS; THE OPENABLE AREA OF
WHICH IS NOT LESS THAN 5% OF THE CONDITIONED FLOOR
AREA OF THE NATURALLY VENTILATED SPACE. WHERE
OPENINGS ARE COVERED WITH LOUVERS OR OTHERWISE
OBSTRUCTED, OPENABLE AREA SHALL BE BASED ON THE
FREE UNOBSTRUCTED AREA THROUGH THE OPENING. THE
MEANS TO OPEN REQUIRED OPERABLE OPENINGS SHALL BE
READILY ACCESSIBLE TO BUILDING OCCUPANTS WHENEVER
THE SPACE IS OCCUPIED.
MINIMUM VENTILATION
EACH SPACE THAT IS NOT NATURALLY VENTILATED SHALL BE
VENTILATED WITH A MECHANICAL SYSTEM CAPABLE OF
PROVIDING AN OUTDOOR AIR RATE NO LESS THAN AS
REQUIRED BY THE CALIFORNIA ENERGY EFFICIENCY
STANDARDS.
PRE-OCCUPANCY VENTILATION PURGE
THE MINIMUM RATE OF OUTDOOR AIR OR THREE COMPLETE
AIR CHANGES SHALL BE SUPPLIED TO THE ENTIRE BUILDING
DURING THE ONE-HOUR PERIOD IMMEDIATELY BEFORE THE
BUILDING IS NORMALLY OCCUPIED.
DEMAND CONTROL VENTILATION
HVAC SINGLE ZONE SYSTEMS WITH AN OUTDOOR AIR
ECONOMIZER AND WITH A DESIGN OCCUPANT DENSITY, OR A
MAXIMUM OCCUPANT LOAD FACTOR FOR EGRESS PURPOSES
GREATER THAN OR EQUAL TO 25 PEOPLE PER 1000 SF SHALL
HAVE DEMAND CONTROL VENTILATION OR OCCUPANT
SENSOR VENTILATION CONTROLS.
TIME CONTROL
EACH SPACE-CONDITIONING SYSTEM SHALL BE INSTALLED
WITH CONTROLS THAT ARE CAPABLE OF AUTOMATICALLY
SHUTTING OFF THE SYSTEM DURING PERIODS OF NON-USE
AND SHALL HAVE EITHER AN AUTOMATIC TIME SWITCH
CONTROL DEVICE WITH AN ACCESSIBLE MANUAL OVERRIDE
THAT ALLOWS OPERATION OF THE SYSTEM FOR UP TO FOUR
HOURS; OR AN OCCUPANCY SENSOR; OR A FOUR-HOUR
TIMER THAT CAN BE MANUALLY OPERATED.
SETBACK AND SETUP CONTROL
THE CONTROL SHALL AUTOMATICALLY RESTART AND
TEMPORARILY OPERATE THE SYSTEM AS REQUIRED TO
MAINTAIN A SETBACK HEATING THERMOSTAT SETPOINT.
IF THE SYSTEM PROVIDES MECHANICAL HEATING AND A
SETUP COOLING THERMOSTAT SETPOINT IF THE SYSTEM
PROVIDES MECHANICAL COOLING.
OUTDOOR DAMPER CONTROL
OUTDOOR AIR SUPPLY AND EXHAUST EQUIPMENT SHALL BE
INSTALLED WITH DAMPERS THAT AUTOMATICALLY CLOSE
UPON FAN SHUTDOWN.
ISOLATION ZONES
EACH SPACE-CONDITIONING SYSTEM SERVING MULTIPLE
ZONES WITH A COMBINED CONDITIONED FLOOR AREA OF
MORE THAN 25,000 SQUARE FEET SHALL BE DESIGNED,
INSTALLED, AND CONTROLLED TO SERVE ISOLATION AREAS.
AUTOMATIC DEMAND SHED CONTROLS
HVAC SYSTEMS WITH DDC TO ZONE LEVEL SHALL BE
PROGRAMMED TO ALLOW CENTRALIZED DEMAND SHED FOR
NON-CRITICAL ZONES.
ECONOMIZER FAULT DETECTION AND DIAGNOSTICS (FDD)
AIR-COOLED UNITARY DIRECT-EXPANSION UNITS EQUIPPED
WITH AN ECONOMIZER AND MECHANICAL COOLING AT AHRI
CONDITIONS OF GREATER THAN OR EQUAL TO 54.0 MBH
SHALL INCLUDE A FDD SYSTEM.
DUCT INSULATION
ALL AIR DISTRIBUTION SYSTEM DUCTS AND PLENUMS SHALL
BE INSTALLED, SEALED AND INSULATED TO MEET THE
REQUIREMENTS OF THE 2019 CMC SECTIONS 601, 602, 603,
604, 605.
110.2(a)
110.2(b)
110.2(c)
120.2(h)
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
11. 12.
13. 14.
15. 16.
17. 18.
19. 20.
21. 22.
23. 24.
25. 26.
27. 28.
29. ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND IN
ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, LAWS, PERMITS, AND THE CONTRACT DOCUMENTS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION ON THE SITE.
THE CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS,
AND EXACT LOCATIONS AND ELEVATIONS OF PIPING BEFORE STARTING WORK. SHOULD A DISCREPANCY APPEAR IN THE CONTRACT DOCUMENTS, OR
BETWEEN THE CONTRACT DOCUMENTS AND EXISTING CONDITIONS, NOTIFY THE ARCHITECT AT ONCE FOR INSTRUCTION ON HOW TO PROCEED.
THE MECHANICAL CONTRACTOR SHALL ACQUIRE AND PAY FOR ALL PERMITS AND FEES.
COORDINATE MECHANICAL WORK WITH ALL OTHER TRADES (ELECTRICAL, ARCHITECTURAL, STRUCTURAL, CIVIL, AND LANDSCAPE). REFER TO
ELECTRICAL, ARCHITECTURAL,STRUCTURAL, CIVIL, AND LANDSCAPE DRAWINGS AND SPECIFICATIONS FOR DETAILS. COORDINATION SHALL OCCUR PRIOR TO FABRICATION, PURCHASE, AND/OR INSTALLATION OF ALL WORK.
COORDINATE MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION SYSTEM ROUTING PRIOR TO INSTALLATION. DUCTWORK ROUTING TAKES PRECEDENCE OVER OTHER DISCIPLINES INCLUDING FIRE PROTECTION.
DRAWINGS ARE DIAGRAMMATIC IN NATURE. PROVIDE ALL FITTINGS, TRANSITIONS AND/OR OFFSETS AS REQUIRED FOR A COMPLETE SYSTEM.
PRIOR TO COMMENCING ANY WORK VERIFY ALL EQUIPMENT LOCATIONS WITH
THE GENERAL CONTRACTOR, OTHER TRADES, ARCHITECT AND STRUCTURAL ENGINEER.
MECHANICAL SYSTEMS SEISMIC RESTRAINTS SHALL CONFORM TO "SEISMIC RESTRAINT MANUAL: GUIDELINES FOR MECHANICAL SYSTEMS" AS PUBLISHED BY SMACNA 3RD EDITION 2008, ANSI/SMACNA 001-2008.
THE MECHANICAL CONTRACTOR IS RESPONSIBLE FOR THE SAFE KEEPING OF HIS OWN PROPERTY ON THE JOB SITE. OWNER ASSUMES NO RESPONSIBILITY
FOR THE PROTECTION OF PROPERTIES AGAINST, FIRE, SMOKE, THEFT, AND ENVIRONMENTAL CONDITIONS.
MECHANICAL MATERIALS, EQUIPMENT, DUCTWORK AND PIPING SHALL BE STORED IN ORDERLY PROFESSIONAL FASHION. ALL ITEMS SHALL BE COVERED AND PROTECTED FROM RAIN AND ALL OTHER ENVIRONMENTAL CONDITIONS.
VERIFY AND COORDINATE THE MAINTENANCE ACCESS AND CODE REQUIRED CLEARANCES FOR ALL MECHANICAL EQUIPMENT. INSTALL ALL WORK AND
COORDINATE THE WORK OF OTHER TRADES TO MAINTAIN CODE REQUIRED CLEARANCE AND ACCESS FOR PROPER MAINTENANCE OF EQUIPMENT.
PROVIDE EQUIPMENT TAGS FOR ALL MECHANICAL EQUIPMENT. TAG SHALL BE MADE OF BAKELITE WITH ETCHED 1/2" HIGH LETTERS. LOCATE TAG ON EQUIPMENT NEAR MANUFACTURERS NAMEPLATE.
PROVIDE DUCTWORK THAT CONFORMS TO THE "HVAC DUCT CONSTRUCTION STANDARDS - METAL AND FLEXIBLE" AS PUBLISHED IN THE LATEST EDITION OF THE CALIFORNIA MECHANICAL CODE. ACOUSTICAL LINING SHALL CONFORM TO SMACNA 2006 EDITION (ANSI / SMACNA 006-2006) STANDARDS.
FLEXIBLE DUCTWORK SHALL BE USED FOR CONNECTIONS TO AIR TERMINAL
DEVICES IN CONCEALED, LOW PRESSURE, ENVIRONMENTAL AIR DUCT SYSTEMS. FLEXIBLE DUCT CONNECTIONS SHALL BE 5’-0” MAXIMUM LENGTH
AND SHALL BE INSTALLED IN ACCORDANCE WITH SMACNA HVAC DUCT CONSTRUCTION STANDARDS.
REFRIGERANT PIPING SHALL BE SIZED AND ROUTED IN ACCORDANCE WITH MANUFACTURER’S REQUIREMENTS. REFRIGERANT SYSTEM SHALL INCLUDE
ALL ADDITIONAL TRAPS, VALVES, AND ACCESSORIES REQUIRED BY THE MANUFACTURER FOR THE INSTALLED PIPE ROUTING. PROVIDE MINIMUM 1”
CLOSED CELL FOAM INSULATION FOR ALL REFRIGERANT PIPING, ARMACELL “ARMAFLEX” OR SIMILAR. REFER TO SPECIFICATIONS.
THE MECHANICAL CONTRACTOR SHALL PROVIDE ALL CONTROL WIRING IN CONDUIT.
THERMOSTATS SHALL BE MOUNTED 48" ABOVE FINISHED FLOOR UNLESS NOTED OTHERWISE.
THE MECHANICAL CONTRACTOR SHALL PROVIDE AS-BUILT DRAWINGS.
DRAWINGS SHALL BE SUBMITTED IN AUTO CAD FORMAT. AS-BUILT DRAWINGS
SHALL BE COMPLETED AND SUBMITTED TO ENGINEER/ARCHITECT PRIOR TO SUBSTANTIAL COMPLETION. ENGINEER WILL NOT PERFORM PUNCH LIST UNTIL AS-BUILT DRAWINGS ARE RECEIVED.
PROVIDE COMPLETE AIR AND WATER BALANCE FOR ALL MECHANICAL SYSTEMS. BALANCING CONTRACTOR SHALL BE AN INDEPENDENT THIRD PARTY AND A MEMBER OF "AABC" OR THE "NEBB". MECHANICAL CONTRACTOR
SHALL PROVIDE ALL NECESSARY BELTS SHEAVES AND PULLEYS AS REQUIRED
BY THE BALANCING CONTRACTOR TO COMPLETE THE BALANCING OF THE SYSTEM.
DUCT SIZES INDICATED ON PLANS ARE THE "FREE" INSIDE DIMENSION OF THE DUCT. THE CONTRACTOR SHALL INCREASE THE SIZE OF THE DUCT TO ACCOMMODATE ACOUSTICAL AND / OR PERFORATED LINERS.
SEAL ALL DUCT SYSTEMS AIRTIGHT USING MASTIC AND/OR LIQUID ELASTIC SEALANT. "DUCT TAPE" SHALL NOT BE USED.
PROVIDE VOLUME DAMPERS FOR EACH SUPPLY DIFFUSER AS WELL AS FOR
RETURN AND EXHAUST OPENINGS AS REQUIRED BY THE BALANCING CONTRACTOR TO BALANCE THE SYSTEM. LOCATE DAMPER AS FAR UPSTREAM AS POSSIBLE. FOR ALL VOLUME DAMPERS LOCATED ABOVE CEILINGS PROVIDE 12" LONG 1/2" WIDE FLUORESCENT ORANGE TAPE TO MARK DAMPER LOCATIONS.
PROVIDE "PETE'S PLUG" TYPE TEST WELLS BEFORE AND AFTER EACH EACH
PIECE OF EQUIPMENT REQUIRING BALANCING OR MONITORING IN THE
HYDRONIC SYSTEMS INCLUDING BUT NOT LIMITED TO COILS, HEAT
EXCHANGERS, CONTROL VALVES, TEMPERATURE AND / OR PRESSURE SENSORS, ETC. PROVIDE ADDITIONAL TEST WELLS AS REQUIRED BY THE COMMISSIONING AGENT.
DUCT SYSTEMS USED WITH BLOWER TYPE EQUIPMENT WHICH ARE PORTIONS
OF HEATING COOLING, ABSORPTION, EVAPORATIVE COOLING OR OUTDOOR AIR VENTILATION SYSTEM SHALL BE SIZED IN ACCORDANCE WITH CHAPTER 17 OF THE CALIFORNIA MECHANICAL CODE.
AIR-MOVING SYSTEMS SUPPLYING AIR IN EXCESS OF 2000 CFM SHALL BE
INTERLOCKED TO AND SHUTDOWN BY AREA WIDE FIRE ALARM SYSTEM SIGNAL. FOR BUILDINGS WITHOUT AREA WIDE SYSTEM THE EQUIPMENT SHALL
BE EQUIPPED WITH AN AUTOMATIC SHUTOFF ACTIVATED BY SMOKE DETECTOR LOCATED IN THE MAIN SUPPLY-AIR DUCT.
PROVIDE TURNING VANES IN ALL 90° MITERED ELBOWS
DUCT SYSTEMS SHALL BE SEALED TO A LEAKAGE RATE NOT TO EXCEED 6% OF THE NOMINAL AIR HANDLER AIRFLOW RATE. CONFIRM THROUGH FIELD VERIFICATION AND DIAGNOSTIC TESTING.
ALL MECHANICAL EQUIPMENT SHALL BE INSTALLED WITH ADEQUATE
CLEARANCE FOR MAINTENANCE ACCESS, PER MANUFACTURER'S
REQUIREMENTS.
REFER TO ARCHITECTURAL PLANS FOR LOCATION OF FIRE AND/OR SMOKE SEPARATION WALLS. THE MECHANICAL CONTRACTOR SHALL PROVIDE FIRE AND/OR SMOKE DAMPERS FOR ALL RATED WALLS/CEILINGS/ASSEMBLIES. 2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R.
2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R.; (2021 INTERNATIONAL BUILDING CODE OF THE INTERNATIONAL CODE
COUNCIL, WITH CALIFORNIA AMENDMENTS)
2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R.; (2020 NATIONAL ELECTRICAL CODE OF THE NATIONAL FIRE PROTECTION
ASSOCIATION, NFPA)
2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R.; (2021 UNIFORM MECHANICAL CODE OF THE INTERNATIONAL ASSOCIATION OF
PLUMBING AND MECHANICAL OFFICIALS, IAPMO)
2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R.; (2021 UNIFORM PLUMBING CODE OF THE INTERNATIONAL ASSOCIATION OF
PLUMBING AND MECHANICAL OFFICIALS, IAPMO)
2022 ENERGY CODE (CEC), PART 6, TITLE 24 C.C.R.;
2022 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R.;
(2021 INTERNATIONAL FIRE CODE OF THE INTERNATIONAL CODE COUNCIL) 2022 CALIFORNIA GREEN BUILDING CODE (CAL GREEN), PART 11, TITLE 24 C.C.R. 2022 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 C.C.R. 2022 TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS.
PARTIAL LIST OF APPLICABLE STANDARDS
ASHRAE 62.1 VENTILATION FOR ACCEPTABLE INDOOR AIR VERSION 2019
QUALITY
ASHRAE 55 THERMAL COMFORT FOR HUMAN OCCUPANCY VERSION 2017 ASHRAE G36 HIGH PERFORMANCE SEQUENCE OF OPERATIONS
FOR HVAC SYSTEMSVERSION 2018
NFPA 13 AUTOMATIC SPRINKLER SYSTEMS 2016 EDITION
(CALIFORNIA AMENDED)
NFPA 14 STANDPIPE SYSTEMS2016 EDITION
(CALIFORNIA AMENDED)
NFPA 17 DRY CHEMICAL EXTINGUISHING SYSTEMS2017 EDITION
NFPA 17A WET CHEMICAL EXTINGUISHING SYSTEMS2017 EDITION NFPA 20 STATIONARY PUMPS2016 EDITION
NFPA 24 PRIVATE FIRE SERVICE MAINS2016 EDITION
(CALIFORNIA AMENDED)
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2016 EDITION (CALIFORNIA AMENDED)
(NOTE: SEE UL STANDARD 1971 FOR "VISUAL
DEVICES")
NFPA 80 FIRE DOOR AND OTHER OPENING PROTECTIVES 2016 EDITION NFPA 253 CRITICAL RADIANT FLUX OF FLOOR COVERING 2019 EDITION
SYSTEMS
NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS 2015 EDITION (CALIFORNIA AMENDED)
BUILDING CODES: (APPLICABLE AS OF JANUARY 1, 2023)
ABBREVIATIONDESCRIPTION
AAIR, AMPS
AAVAUTOMATIC AIR VENT
ABVABOVE
ACAIR CONDITIONING
ACTACOUSTICAL CEILING TILE
ADACCESS DOOR
AFFABOVE FINISH FLOOR
AFUEANNUAL FUEL UTILIZATION EFFICIENCY
AHJAUTHORITY HAVING JURISDICTION
AHUAIR HANDLING UNIT
AMBAMBIENT
APDAIR PRESSURE DROP
ASHRAEAMERICAN SOCIETY OF HEATING, REFRIGERATION
AND AIR-CONDITIONING ENGINEERS, INC.
ASSYASSEMBLY
ATMATMOSPHERE
BBOILER
BFFBELOW FINISHED FLOOR
BHPBRAKE HORSE POWER
BELBELOW
BODBOTTOM OF DUCT
BOPBOTTOM OF PIPE
BTUHBRITISH THERMAL UNIT PER HOUR
BVBALL VALVE
CCONDENSATE PIPING
CACOMPRESSED AIR
CAPCAPACITY
CDCEILING DIFFUSER, CONDENSATE DRAIN
CFGCEILING FIRE DAMPER
CFMCUBIC FEET PER MINUTE
CGCEILING GRILLE
CHCHILLER
CHRCHILLED WATER RETURNED
CHSCHILLED WATER SUPPLY
CVCHECK VALVE
CLGCEILING, COOLING
COCARBON MONOXIDE SENSOR
CO2CARBON DIOXIDE SENSOR
COMBCOMBINATION, COMBUSTION
CONDCONDENSER, CONDENSATE
CONTCONTINUE, CONTROL
COPCOEFFICIENT OF PERFORMANCE
CRCONDENSER WATER RETURN
CSCONDENSER WATER SUPPLY
CxCOMISSIONING
CxACOMISSIONING AGENT
(D)DEMOLISH
DBDRY BULB
dBDECIBEL
DDCDIRECT DIGITAL CONTROL
DIADIAMETER
DNDOWN
ØDIAMETER
EXISTEXISTING
(E)EXISTING
EAEXHAUST AIR
EATENTERING AIR TEMPERATURE
EERENERGY EFFICIENCY RATIO
EFEXHAUST FAN
EGEXHAUST GRILLE
ELECELECTRICAL
EMSENERGY MANAGEMENT SYSTEM
EQUIVEQUIVALENT
ESPEXTERNAL STATIC PRESSURE
ETEXPANSION TANK
EVAPEVAPORATOR, EVAPORATIVE
EWTENTERING WATER TEMPERATURE
FFAHRENHEIT
FCFLUID COOLER
FCUFAN COIL UNIT
FDFIRE DAMPER
FLAFULL LOAD AMPS
FLRFLOOR
FLTRFILTER
FPMFEET PER MINUTE
FPSFEET PER SECOND
FSDCOMBINATION FIRE SMOKE DAMPER
FTFOOT, FEET
FVFACE VELOCITY
GAGAGE
GALGALLONS
GPMGALLONS PER MINUTE
GRDGRILLES, REGISTERS, AND DIFFUSERS
GWRGLYCOL WATER RETURN PIPING
GWSGLYCOL WATER SUPPLY PIPING
HHUMIDISTAT, HEIGHT
HDHEAD
HORIZHORIZONTAL
HPHORSE POWER, HEAT PUMP
HTGHEATING
HVACHEATING VENTILATION AND AIR CONDITIONING
HHRHEATING WATER RETURN
HHSHEATING WATER SUPPLY
HZHERTZ
IAQINDOOR AIR QUALITY
ININCHES
IN WCINCHES WATER COLUMN
KWKILOWATT
LATLEAVING AIR TEMPERATURE
LBSPOUNDS
LRALOCKED ROTOR AMPS
LVRLOUVER
LWTLEAVING WATER TEMPERATURE
MATMIXED AIR TEMPERATURE
MBHTHOUSAND BRITISH THERMAL UNITS PER HOUR
MECHMECHANICAL
MERVMINIMUM EFFICIENCY REPORTING VALUE
MCMECHANICAL CONTRACTOR
MCAMINIMUM CIRCUIT AMPACITY
MOCPMAXIMUM OVER CURRENT PROTECTION
NANOT APPLICABLE
NCNORMALLY CLOSED, NOISE CRITERIA
NICNOT IN CONTRACT
NONORMALLY OPEN
NTSNOT TO SCALE
OAOUTSIDE AIR
OBDOPPOSED BLADE DAMPER
OCON CENTER
ODOUTSIDE DIAMETER
PPUMP
PDPRESSURE DROP
POCPOINT OF CONNECTION
PODPOINT OF DISCONNECTION
PRVPRESSURE REDUCING VALVE
PSIPOUNDS PER SQUARE INCH
RARETURN AIR, RELIEF AIR
REFREFRIGERANT
RGRETURN GRILLE
RHRELATIVE HUMIDITY
RLREFRIGERANT LIQUID LINE
RLARATED LOAD AMPS
RPMREVOLUTIONS PER MINUTE
RTUROOF TOP UNIT
SSENSOR
SASUPPLY AIR, SOUND ATTENUATOR
SATSUPPLY AIR TEMPERATURE
SFSUPPLY FAN, SQUARE FOOT
SGSUPPLY GRILLE
SIMSIMILAR
SLREFRIGERANT SUCTION LINE
SMACNASHEET METAL AND AIR-CONDITIONING
CONTRACTOR NATIONAL ASSOCIATION
SOOSEQUENCE OF OPERATION
STSOUND TRAP
TDTEMPERATURE DIFFERENCE
TDHTOTAL DYNAMIC HEAD
TEMPTEMPERATURE
TGTRANSFER GRILLE
TODTOP OF DUCT
TOPTOP OF PIPE
TOSTOP OF STEEL / STRUCTURE
TSPTOTAL STATIC PRESSURE
T'STATTHERMOSTAT
TUTERMINAL UNIT
TYPTYPICAL
UHUNIT HEATER
VVOLT
VAVVARIABLE AIR VOLUME
VDVOLUME DAMPER
VELVELOCITY
VENTVENTILATION, VENTILATOR
VFDVARIABLE FREQUENCY DRIVE
WWATT, WIDE, WATER
W/WITH
W/OWITHOUT
WBWET BULB TEMPERATURE
WTWEIGHT
MOTORIZED DAMPER
SP
BP
SD
AF
A
T
MD
OPERABLE WINDOW
CONTACT
WC
DCOPERABLE DOOR
CONTACT
DP
DUCT SMOKE DETECTOR
TEMPERATURE TRANSMITTER
AQUASTAT
AIRFLOW MEASURING UNIT
DUCT STATIC PRESSURE
TRANSMITTER
BUILDING PRESSURE
TRANSMITTER
DIFFERENTIAL
PRESSURE
TRANSMITTER
VFD
DDC
VARIABLE FREQUENCY DRIVE
MAIN BUILDING DIRECT DIGITAL CONTROL PANEL
AUTOMATIC CONTROL VALVE, 2-WAY
AUTOMATIC CONTROL VALVE, 3-WAY
----
TYPE
TYPEDESCRIPTION
T THERMOSTAT
Z ZONE TEMPERATURE SENSOR - W/ LOCAL OVERRIDE / DISPLAY
S SPACE TEMPERATURE SENSOR- STAINLESS STEEL FLAT PLATE
R HUMIDISTAT OR HUMIDITY SENSOR
C CARBON DIOXIDE SENSOR
CO CARBON MONOXIDE SENSOR
EXAMPLE
TCR= THERMOSTAT WITH CO2 AND HUMIDISTAT SENSOR
GENERAL CONTROL NOTES
1. 2.
3. 4.
BUILDING EMS TO INTERCONNECT WITH EXISTING CAMPUS EMS SYSTEM FOR FULL CONTROL AND MONITORING.
BUILDING EMS TO CONNECT TO LIGHTING CONTROL PANELS THROUGH BACNET INTERFACE CARD.
BUILDING CONTROLS TO COMPLY WITH OWNER CONTROLS STANDARDS.
MOTOR STARTERS SHALL BE PROVIDED BY ELECTRICAL CONTRACTOR.
STARTERS SHALL BE EQUAL TO CERUS MODEL 'BAS'.
DEFINITION:
THERMOSTAT - FACTORY PROVIDED WITH ON-BOARD CONTROL LOGIC AND LOCAL USEABILITY CONTROLS. CONNECT TO EMS FOR MONITORING ONLY.
ZONE TEMPERATURE SENSOR W/ LOCAL OVERRIDES - FIELD PROVIDED SENSOR WITH WIRING TO CENTRAL EMS WITH LOCAL USER OVERRIDE CONTROLS. MOUNT FLUSH AND AT EQUAL HEIGHT WITH LIGHT SWITCHES AND OTHER DEVICES.
SENSOR MODEL TO BE APPROVED BY THE ARCHITECT.
SPACE TEMPERATURE SENSOR W/O LOCAL OVERRIDES - FIELD PROVIDED
SENSOR WITH WIRING TO CENTRAL EMS WITHOUT LOCAL USER OVERRIDE CONTROLS EQUAL TO KELE ST-S. EXACT SENSOR TYPE TO MATCH ARCHITECTURAL FEATURES AND TO BE APPROVED BY THE ARCHITECT. 24x10
TRANSITION - ECCENTRIC
DUCT RISE / DROP W/ 90° ELBOWS
(RECTANGULAR DUCTS)
45° ELBOW, R/D OR R/W=1.5
DUCT RISE / DROP W/ 90° ELBOWS
(ROUND AND / OR OVAL DUCT)
DUCT RISE / DROP W/ 45° ELBOWS
(RECTANGULAR DUCTS)
DUCT RISE / DROP W/ 45° ELBOWS
(ROUND AND / OR OVAL DUCTS)
90° ELBOW, R/D OR R/W=1.5
TRANSITION OR REDUCER
SOUNDLINED DUCTWORK
RECTANGULAR DUCT DN
RECTANGULAR DUCT UP
ROUND OR OVAL DUCT DN
ROUND OR OVAL DUCT UP
FLEXIBLE CONNECTION
DUCT SIZE (CLEAR INSIDE DIMENSION IN
INCHES)
TRANSITION - RECTANGULAR TO ROUND
RADIUS TEE
SQUARE TEE W/ TURNING VANES
RADIUS TAP IN
BULLHEAD TEE
MITERED ELBOW WITH TURNING
VANES
90° CONICAL TAP
90° STRAIGHT TAP
45° TAP
90° TAP WITH 45° BEVEL
WYE FITTING
RETURN AIR DUCT UP AND DOWN
SUPPLY AIR DUCT UP AND DOWN
RETURN DUCT ROOF PENETRATION
SUPPLY DUCT ROOF PENETRATION
EXHAUST AIR DUCT UP AND DOWN
EXHAUST DUCT ROOF PENETRATION
WYE AND 45° ELBOW W/ REDUCER
(ROUND AND / OR OVAL DUCT)
CHILLED WATER SUPPLY PIPING
CHILLED WATER RETURN PIPING
HEATING WATER SUPPLY PIPING
HEATING WATER RETURN PIPING
CHS
CHR
HHS
HHR
CONTINUATION OF PIPING
DUCT SMOKE DETECTOR
SHUT-OFF VALVE ABOVE GRADE
MANUAL VOLUME DAMPER
SMOKE DAMPER
FIRE DAMPER
FIRE / SMOKE DAMPER
BACK DRAFT DAMPER
SYMBOLDESCRIPTION
SD
SUPPLY DIFFUSER
RETURN GRILLE
EXHAUST GRILLE
ELECTRONIC REMOTE DAMPER
MECHANICAL REMOTE DAMPER
REMOTE DAMPER CONTROL LOCATIONRDCL
POINT OF CONNECTION
POINT OF DISCONNECTION
REFRIGERANT PIPINGREF
CONTINUATION OF DUCT
(NOT TO SCALE)
5.201.1
5.504.3
5.504.5.3
5.504.5.3.1
5.410.3
5.410.4.3.1
5.410.4.4
5.410.4
5.410.4.5
5.504.4.1
5.506.1
5.506.2
702.1
702.2
703.1
COMPLY WITH REQUIREMENTS OF CALIFORNIA ENERGY
CODE (CCR TITLE-24, PART 6, 2019)
PERFORM TESTING AND ADJUSTING PROCEDURES IN
ACCORDANCE WITH INDUSTRY BEST PRACTICES AND
APPLICABLE NATIONAL STANDARDS ON EACH SYSTEM.
TESTING AND ADJUSTING OF SYSTEMS SHALL BE REQUIRED
FOR BUILDINGS LESS THAN 10,000 SQFT OR NEW SYSTEMS
TO SERVE AN ADDITION OR ALTERATION.
BEFORE A NEW SPACE-CONDITIONING SYSTEM SERVING A
BUILDING OR SPACE IS OPERATED FOR NORMAL USE, THE
SYSTEM SHALL BE BALANCED IN ACCORDANCE WITH THE
PROCEDURES DEFINED BY THE TESTING, ADJUSTING, AND
BALANCING BUREAU NATIONAL STANDARDS; THE NATIONAL
ENVIRONMENTAL BALANCING BUREAU PROCEDURAL
STANDARDS; OR ASSOCIATED AIR BALANCE COUNCIL
NATIONAL STANDARDS.
AFTER COMPLETION OF TESTING, ADJUSTING AND
BALANCING, PROVIDE A FINAL REPORT OF TESTING SIGNED
BY THE INDIVIDUAL RESPONSIBLE FOR PERFORMING THESE
SERVICES.
BUILDING OWNER SHALL BE PROVIDED WITH DETAILED
OPERATING AND MAINTENANCE INSTRUCTIONS AND COPIES
OF GUARANTEES AND WARRANTIES FOR EACH SYSTEM
PRIOR TO FINAL INSPECTION.
ADHESIVES, ADHESIVE BONDING PRIMERS, ADHESIVE
PRIMERS, SEALANTS, SEALANT PRIMERS AND CAULKS
SHALL COMPLY WITH LOCAL OR REGIONAL AIR POLLUTION
CONTROL OR AIR QUALITY MANAGEMENT DISTRICT RULES
WHERE APPLICABLE OR SCAQMD RULE 1168 VOC LIMITS, AS
SHOWN IN TABLES 5.504.4.1 & 5.504.4.2.
AEROSOL ADHESIVES AND SMALLER UNIT SIZES OF
ADHESIVES AND SEALANT OR CAULKING COMPOUNDS (IN
UNITS OF PRODUCT, LESS PACKAGING, WHICH DO NOT
WEIGH MORE THAN ONE POUND AND DO NOT CONSIST OF
MORE THAN 16 FLUID OUNCES) SHALL COMPLY WITH
STATEWIDE VOC STANDARDS AND OTHER REQUIREMENTS,
INCLUDING PROHIBITIONS ON USE OF CERTAIN TOXIC
COMPOUNDS, OF CALIFORNIA CODE OF REGULATIONS,
TITLE 17, COMMENCING WITH SECTION 94507.
AT THE TIME OF ROUGH INSTALLATION AND DURING
STORAGE ON THE CONSTRUCTION SITE UNTIL FINAL
STARTUP OF THE HEATING, COOLING, AND VENTILATION
EQUIPMENT, ALL DUCT AND OTHER AIR DISTRIBUTION
COMPONENT OPENINGS SHALL BE COVERED WITH TAPE,
PLASTIC, SHEETMETAL, OR OTHER METHODS ACCEPTABLE
TO THE ENFORCING AGENCY TO REDUCE THE AMOUNT OF
DUST, WATER, AND DEBRIS WHICH MAY ENTER THE
SYSTEM.
IN MECHANICALLY VENTILATED BUILDINGS, PROVIDE
REGULARLY OCCUPIED AREAS OF THE BUILDINGS WITH AIR
FILTRATION MEDIA FOR OUTSIDE AND RETURN AIR THAT
PROVIDES AT LEAST A MERV 13. MERV 13 FILTERS SHALL BE
INSTALLED PRIOR TO OCCUPANCY AND
RECOMMENDATIONS FOR MAINTENANCE WITH FILTERS OF
THE SAME VALUE SHALL BE INCLUDED IN THE M&O MANUAL.
INSTALLED FILTERS SHALL BE CLEARLY LABELED BY THE
MANUFACTURER INDICATING THE MERV RATING.
FOR MECHANICALLY OR NATURALLY VENTILATED SPACES
IN BUILDINGS, MEET THE MINIMUM REQUIREMENTS OF
SECTION 120.1 OF THE CALIFORNIA ENERGY CODE, CCR
TITLE 24, PART 6 AND CHAPTER 4 OF CCR, TITLE 8 OR THE
APPLICABLE LOCAL CODE WHICHEVER IS MORE
STRINGENT.
FOR BUILDINGS EQUIPPED WITH DEMAND CONTROL
VENTILATION, CO2 SENSORS AND VENTILATION CONTROLS
SHALL BE SPECIFIED AND INSTALLED IN ACCORDANCE WITH
THE REQUIREMENTS OF THE LATEST EDITION OF THE
CALIFORNIA ENERGY CODE, CCR, TITLE 24, PART 6, SECTION
120.1(c).1.
HVAC SYSTEM INSTALLERS SHALL BE TRAINED AND
CERTIFIED IN THE PROPER INSTALLATION OF HVAC
SYSTEMS INCLUDING DUCTS AND EQUIPMENT BY A
NATIONALLY OR REGIONALLY RECOGNIZED TRAINING OR
CERTIFICATION PROGRAM. UNCERTIFIED PERSONS MAY
PERFORM HVAC INSTALLATIONS WHEN UNDER THE DIRECT
SUPERVISION AND RESPONSIBILITY OF A PERSON TRAINED
AND CERTIFIED TO INSTALL HVAC SYSTEMS OR
CONTRACTOR LICENSED TO INSTALL HVAC SYSTEMS.
ACCEPTABLE HVAC TRAINING AND CERTIFICATION
PROGRAMS INCLUDE BUT ARE NOT LIMITED TO THE
FOLLOWING: 1) STATE CERTIFIED APPRENTICESHIP
PROGRAMS, 2) PUBLIC UTILITY TRAINING PROGRAMS, 3)
TRAINING PROGRAMS SPONSORED BY TRADE, LABOR, OR
STATEWIDE ENERGY CONSULTING OR VERIFICATION
ORGANIZATIONS, 4) PROGRAMS SPONSORED BY
MANUFACTURING ORGANIZATIONS, 5) OTHER PROGRAMS
ACCEPTABLE TO THE ENFORCING AGENCY.
SPECIAL INSPECTORS MUST BE QUALIFIED AND ABLE TO
DEMONSTRATE COMPETENCE IN THE DISCIPLINE THEY ARE
INSPECTING.
THE BUILDING OWNER SHALL BE PROVIDED WITH THE FINAL
REPORT OF ALL INSPECTION VERIFICATIONS AND REPORTS
REQUIRED BY THE ENFORCING AGENCY.
1 M7.01
DOOR LOUVER
TRANSOM LOUVER
UNDERCUT DOOR
SUPPLY AIR FLOW DIRECTION
OUTSIDE AIR FLOW DIRECTION
EXHAUST AIR FLOW DIRECTION
RETURN AIR FLOW DIRECTION
KEYNOTE SYMBOL
EQUIPMENT TAG SYMBOL
DETAIL NUMBER
SSHEET NUMBER
DIFFUSER IDENTIFICATION, NECK SIZE
AIR FLOW, NUMBER OF OCCURRENCES
D/L
T/L
U/C
EA
OA
?
?
RA
SA
S-1: 12"
200TYP.3
(NOT TO SCALE)
1. 2.
3. 4.
5. 6.
ALL EQUIPMENT, PIPING, UTILITIES, AND THEIR CONNECTIONS SHALL BE
SEISMICALLY BRACED PER LATEST CBC AND LATEST EDITION OF SMACNA SEISMIC RESTRAINT MANUAL, BASED ON SEISMIC HAZARD LEVEL A. MAINTAIN A COPY OF SMACNA SEISMIC RESTRAINT MANUAL ON SITE.
LIMITS TO NON-STRUCTURAL ITEMS SUSPENDED FROM CONCRETE FILLED METAL DECKING: HANGERS SUPPORTED BY METAL DECKING WITH
STRUCTURAL CONCRETE FILL MAY BE INSTALLED USING ICC-ES APPROVED ANCHORAGE SYSTEMS. DO NOT SUPPORT UTILITIES FROM METAL DECK WITHOUT CONCRETE. HANGERS FROM CONCRETE FILLED DECK, WHERE OCCURS, ARE LIMITED TO 4-INCH DIAMETER PIPE MAXIMUM. LOCATE HANGERS TWO FLUTES APART ON SAME DECK SPAN. SUPPORT LARGER PIPING FROM STRUCTURAL BEAMS OR COLUMNS. ADD DOUBLE UNISTRUT SPREADERS AS NECESSARY.
PROVIDE SHOP DRAWINGS WITH LARGE SCALE PLANS AND SECTIONS SHOWING HANGERS AND BRACING LOCATIONS. SHOP DRAWINGS SHALL BE
PREPARED BY A STRUCTURAL ENGINEER LICENSED IN THE STATE OF CALIFORNIA AND SHALL BE STAMPED AND SIGNED. INDICATE HANGERS AND BRACING LOADS ON STRUCTURAL FRAMING PLANS. REFERENCE RELEVANT DETAILS FROM SMACNA SEISMIC RESTRAINT MANUAL.
EXPANSION ANCHORS AND EPOXY ANCHORS, WHERE USED, SHALL HAVE A
MINIMUM EMBEDMENT OF EIGHT TIMES THE ANCHOR DIAMETER AND A MINIMUM EDGE DISTANCE OF 10 TIMES THE DIAMETER. EXPANSION ANCHORS AND EPOXY ANCHORS MUST HAVE CURRENT AND VALID ICC REPORT. SHOT PINS ARE NOT ACCEPTABLE.
UNLESS SPECIFIED ON STRUCTURAL DRAWINGS, ANY ALTERATIONS OR
MODIFICATIONS TO A STRUCTURAL ELEMENT BY CUTTING, DRILLING, BORING, BRACING, WELDING, ETC. SHALL HAVE WRITTEN APPROVAL BY THE STRUCTURAL ENGINEER OF RECORD AND DSA PRIOR TO STARTING WORK.
SEE GENERAL NOTES ON STRUCTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
MECHANICAL
LEGENDS AND
GENERAL NOTES
M0.10
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGTITLE-24 MECHANICAL MANDATORY MEASURESGENERAL NOTES
APPLICABLE CODES
ABBREVIATIONS
CONTROL DIAGRAM
CONTROL SYSTEM (PLAN VIEW)
MECH LEGEND CALGREEN BUILDING STANDARDS
NON-RESIDENTIAL MANDATORY MEASURES
ANNOTATION SYMBOLS
GENERAL STRUCTURAL NOTES
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
MECHANICAL
SCHEDULES
M0.20
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING23 - FAN SCHEDULE (EXHAUST) TAG
UNIT
SERVICELOCATION TYPE
AIRFLOW
(CFM)
EXT STAIC
PRESSURE
(IN-WG)
MOTOR DATA SOUND
POWER
(SONES / dBA)
ELECTRICAL
UNIT SIZE
(L"xW"xH")
OPERATING
WEIGHT
(LBS.)EM. POWER
CONTROLS
DETAIL NO.
SPECIFICATION
SECTION REMARKSMFRMODELHPRPMVOLTAGE PHASE
EF-1 GREENHECK SQ-160-VG GENERAL EXHAUST MECH. ROOM 103 CENTRIFUGAL INLINE 3,000 1.5 2 1650 12.6 / 65 208 V 3 28"x26"x26" 175 N 1 23 - VARIABLE REFRIGERANT CONDENSING UNIT SCHEDULE
TAG
UNIT
SERVICELOCATION
NOMINAL
CAPACITY
(TONS)
AMBIENT
(°F)
COOLING HEATING REFRIGERANT PER MODULE
VOLT. PHASE
ELECTRICAL EFFICIENCY
EM.
POWER
(Y / N)
UNIT SIZE (W"xD"xH")OPERATING WEIGHT (LBS.)
INSTALL
DETAIL NO.
CONTROLS
DETAIL NO.
SPECIFICATION
SECTION REMARKSMFRMODELMODULES
RATED
CAPACITY
(MBH)
CAPACITY
(MBH) REFRIGERANT
FACTORY
CHARGE (LBS)
MODULE 1 MODULE 2 MODULE 3
EER IEER COP MODULE 1 MODULE 2 MODULE 3 MODULE 1 MODULE 2 MODULE 3MCA MOCP MCA MOCP MCA MOCP VRF-1 TOSHIBA-CARRIER MMY-UP4801HT6P-UL HEAT PUMP MUP1681HT6P-UL + MUP1681HT6P-UL + MUP1441HT6P-ULAHU-1BUILDING EXTERIOR @ GRADE 40 98 480540R-410A 19.8 /19.8 / 19.8 460 V 3 27.4 40 27.4 40 27.4 35 9.97 - 3.2 N 51.4" x 31.3" x 66.5" 51.4" x 31.3" x 66.5" 51.4" x 31.3" x
66.5"
800 800 750 1, 2, 3
VRF-2 TOSHIBA-CARRIER MMY-UP2401HT6P-UL HEAT PUMPMUP1441HT6P-UL + MUP0961HT6P-ULAHU-2BUILDING EXTERIOR @ GRADE 20 98 240270R-410A 19.8 / 13.2 460 V 3 24.6 35 17.5 20 - - 10.3 - 3.99 N 51.4" x 31.3" x 66.5" 39.6 "x 31.3" x 66.5"-750 550 -1, 2, 3 VRF-3 TOSHIBA-CARRIER MMY-MUP1201FT6P-UL HEAT RECOVERYMMY-MUP1201FT6P-ULVFC-1, VFC-2, VFC-3, VFC-4 BUILDING EXTERIOR @ GRADE 10 98 120135R-410A19.8 460 V 3 24.2 30 - - - - 11.1 - 4.09 N 51.4" x 31.3" x 66.5"--750 --1, 2, 3 23 - VARIABLE REFRIGERANT FAN COIL UNIT SCHEDULE
TAG
UNIT
SERVICE TYPE
OUTDOOR
UNIT
AIRFLOW
(CFM)
COOLING HEATING
OUTPUT
(MBH)
ELECTRICAL
UNIT SIZE
(W"xH"xD")
OPERATING
WEIGHT (LBS)
FILTER BOX SIZE
(W"xH"xD")
FILTER BOX
WEIGHT (LBS)
INSTALL
DETAIL NO.
CONTROL
DETAIL NO.
SPECIFICATION
SECTION REMARKSMFRMODEL NO.TOTAL (MBH)VOLT. PHASE MCA MOCP VFC-1 CARRIER-TOSHIBAMMK-UP0121HP-UL-HIGH WALLEMRWALL MOUNTED VRF-3 320 12.0 13.5 230 1 0.3 15 32 x 12 x 10 30 N / A N / A 1, 2, 3, 7 VFC-2 CARRIER-TOSHIBA MMD-UP0361HP-UL-01-HIGH STATIC DUCT STAFF OFFICE / BREAK ROOM DUCTED VRF-3 1,130 36.0 40.0 230 1 3.4 15 56 x 12 x 30 110 10-5/8 x 27-5/8 x 5/8 55 1, 2, 4, 5, 6 VFC-3 CARRIER-TOSHIBAMMK-UP0241HP-UL-HIGH WALLIDFWALL MOUNTED VRF-3 700 24.0 27.0 230 1 0.6 15 42 x 13 x 10 40 N / A N / A 1, 2, 3, 7 VFC-4 CARRIER-TOSHIBAMMK-UP0241HP-UL-HIGH WALLELECTRICAL ROOM WALL MOUNTED VRF-3 700 24.0 27.0 230 1 0.6 15 42 x 13 x 10 40 N / A N / A 1, 2, 3, 7 23 - SPLIT SYSTEM (MINI) INDOOR UNIT SCHEDULE
TAG
UNIT
SERVICE LOCATION TYPE
NOMINAL
CAPACITY
(TONS)
AIRFLOW
(CFM)
MIN. OSA
(CFM)
COOLING HEATING
POWERED FROM
OUTDOOR UNIT
ELECTRICAL
UNIT SIZE
(L"xW"xH")
OPERATING
WEIGHT (LBS.)
FILTER BOX SIZE
(L"xW"xH")
FILTER BOX
WEIGHT
(LBS.)
INSTALL
DETAIL NO.
CONTROLS
DETAIL NO.
SPECIFICATION
SECTION REMARKSMFRMODEL
CAPACITY
(MBH)
CAPACITY
(MBH)VOLTAGE PHASE
FC-1 TOSHIBA RAV-HB361BTP-UL STEM 113 CEILING DUCTED3 1130 450 36 40 YES 208 V 1 55.25 X 29.63 X 11 100 50 X 10 X 24 55 1, 2, 3, 4 FC-2 TOSHIBA RAV-HB361BTP-UL STEM 112 CEILING DUCTED3 1130 450 36 40 YES 208 V 1 55.25 X 29.63 X 11 100 50 X 10 X 24 55 1, 2, 3, 4 23 - SPLIT SYSTEM (MINI) OUTDOOR UNIT SCHEDULE
TAG
UNIT
SERVICELOCATION
NOMINAL
CAPACITY
(TONS)
AMBIENT
(F)
COOLING HEATING REFRIGERANT ELECTRICAL
UNIT SIZE
(L"xW"xH")
OPERATING
WEIGHT
(LBS.)
INSTALL
DETAIL NO.
CONTROLS
DETAIL NO.
SPECIFICATION
SECTION REMARKSMFRMODEL
CAPACITY
(MBH)SEER / EER
CAPACITY
(MBH)HSPF TYPE
CHARGE
(LBS)VOLTAGE PHASE FLA MCA MOCP
CU-1 TOSHIBA RAV-BP361AT2P-UL FC-1 BUILDING EXTERIOR @ GRADE 3 89 36 18.1 / 11.8 40 10.1 R454B 5.84 208 V 1 30 A 40 A 35.375 X 12.625 X
52.75 230 1
CU-2 TOSHIBA RAV-BP361AT2P-UL FC-2 BUILDING EXTERIOR @ GRADE 3 89 36 18.1 / 11.8 40 10.1 R454B 5.84 208 V 1 30 A 40 A 35.375 X 12.625 X
52.75 230 1
23 - AIR HANDLING UNIT WITH RETURN FAN SCHEDULE
TAG
UNIT
SERVICELOCATION
NOMINAL
CAPACITY
OUTSIDE AIRSUPPLY FAN PERFORMANCERETURN / RELIEF FAN PERFORMANCEDX COOILING COIL DX HEATING COIL DX HEATING COIL FILTERS ELECTRICAL
UNIT SIZE
(L"xW"xH")
OPERATING
WEIGHT (LBS.)
INSTALL
DETAIL NO.
CONTROLS
DETAIL NO.
SPECIFICATION
SECTION REMARKSMFR / MODEL
DESIGN
(CFM)
MIN.CO2
(CFM)
AIRFLOW
(CFM)
TOTAL STATIC
PRESSURE (IN-WG)
DRIVE
TYPE
MOTOR
DATA
AIRFLOW
(CFM)
EXT.
STATIC
PRESSURE
(IN-WG)
DRIVE
TYPE
MOTOR
DATA
TOTAL
(MBH)
SENSIBLE
(MBH)
EAT
DB
(°F)
EAT
WB
(°F)
LAT DB
(°F)
LAT
WB
(°F)
AIR PD
(IN-WG)
NO.
ROWS
NO.
FINS /
INCH
FLUID
TYPE
COIL
CONN.
(IN-Ø)
TOTAL
(MBH)
EAT
(°F)
LAT
(°F)
AIR PD
(IN-WG)
NO.
ROWS
NO.
FINS /
INCH
FLUID
TYPE
COIL
CONN.
(IN-Ø)PRE FINAL VOLTAGEPHASEFLAMCAMOCPHP RPMHP RPM
AHU-1 CARRIER / 39CCHIGH VOLUME SPACEMECH. ROOM 103 40 6,300 3,800 16,0004.25VFD 4 @ 5 1800 9,700 1 VFD 5 1200 446.0 322.9 80 67 61.6 58.4 0.49 3 6 R410A 1-3/8 1,137 41 105.6 0.32 6 6 R410A 1-3/8 MERV 8 MERV 13 460 V 3 38.0 A 39.9 A 45 A 188"x78"x96" 8,725 1, 2, 3, 4, 5, 6, 7, 8, 9 AHU-2 CARRIER / 39CCMEZZANINEMECH. ROOM 103 18 3,000 1,650 7,0004VFD 2 @ 3 1800 4,000 1 VFD 3 1800 231.8 164.6 80 67 58.6 56.6 0.46 4 6 R410A 1-3/8 467 41 101.6 0.32 6 6 R410A 1-3/8 MERV 8 MERV 13 460 V 3 14.4 A 15.6 A 20 A 182"x46"x84" 5,525 1, 2, 3, 4, 5, 6, 7, 8, 9 23 - HVLS CEILING FANS
TAG MFR MODEL LOCATION
AIRFOIL Ø
(FT.)
ELECTRICAL
OPERATING
WEIGHT (LBS)REMARKSVOLTAGE PHASE
HP
(WATTS)AMPS
CF-1 GREENHECK DS-6-20 EXHIBIT SPACE 20 460 V 3 1,100W 4 A 250 1, 2, 3 CF-2 GREENHECK DS-6-20 EXHIBIT SPACE 20 460 V 3 1,100W 4 A 250 1, 2, 3
1. REMARKS:
BACKDRAFT DAMPER
DUCT LINER (WHERE
INDICATED)
POLYESTER - 1"
R=4.2, k-0.23, 0.75 LBS/ CF
INDOOR - EXPOSEDNONE
INDOOR - CONCEALEDFIBERGLASS DUCT WRAP - 1.5"
R=4.2, k-0.29, 0.75 LBS/CFNONE
OUTDOORDOUBLE WALL CONSTRUCTION - FIBERGLASS DUCT WRAP - 2" R=5.6, k-0.24, 0.75 lbs/cf
OSASARATA
LOCATION
SERVICE
DUCT INSULATION SCHEDULE
ALL SIZESELASTOMERIC 1" THICKOUTDOOR - ALUMINUM
INDOOR - NONE1
REFRIGERANT
INSULATIONJACKET REMARKS
PIPE INSULATION SCHEDULE
LARGER THAN 3/4" ACR COPPERBRAZED1
3/4" AND SMALLER ACR COPPERSOLDER1
REFRIGERANT
MATERIALCONNECTION REMARKS
PIPE MATERIAL SCHEDULE
1. REMARKS:
SEE SPECIFICATION SECTION 230719 FOR ADDITIONAL INFORMATION
1. REMARKS:
SEE SPECIFICATION SECTION 232300 FOR ADDITIONAL INFORMATION 23 - VRF FLOW SELECTOR UNIT SCHEDULE
TAG
UNIT
QUANTITY LOCATION
MAX. CAPACITY
(PER PORT)
[MBH]
ELECTRICAL
UNIT SIZE
(W"xH"xD")
OPERATING
WEIGHT (LBS)
CONTROL
DETAIL NO.
SPECIFICATION
SECTION REMARKSMFRMODEL NO.VOLT PHASE MCA MOCP
FS-1TOSHIBA -CARRIER RBM-Y0611FU4PUL 1 STAFF OFFICE / BREAK ROOM 61 208 1 0.75 15 A 13.3 x 11.5 x 18.4 50
1. REMARKS:
PROVIDE SHUT OFF VALVES TO EACH REFRIGERANT PIPE CONNECTED TO FLOW SELECTOR UNIT, LOCATE VALVES NEXT TO THE FLOW SELECTOR UNIT.
1. 2.
3. 4.
5. 6.
7. REMARKS:
VERIFY REFRIGERANT PIPING SIZES AND ROUTING LIMITATIONS WITH MANUFACTURER
FACTORY WIRED PROGRAMMABLE THERMOSTAT
FIELD PROVIDED CONDENSATE PUMP
FACTORY INSTALLED CONDENSATE PUMP (MAX LIFT 27.5")
PROVIDE FACTORY VENTILATION KIT (PTVK)
PROVIDE MERV 13 FILTER KIT (SHARPE FILTER BOX, OR SIMILAR)
COOLING ONLY UNIT
1. 2.
3. 4.
REMARKS:
FIELD PROVIDED CONDENSATE PUMP
FACTORY PROVIDED WIRED THERMOSTAT
PROVIDE MERV 13 FILTER
REFRIGERANT R454B
1. REMARKS:
VERIFY REFRIGERANT PIPING SIZES AND ROUTING LIMITATIONS WITH MANUFACTURER
1. 2.
REMARKS:
PROVIDE WALL CONTROLLER
INTERCONNECT FAN WITH FIRE ALARM PANEL
1. 2.
3. REMARKS:
MOUNT ON CONCRETE PAD
EACH MODULE POWERED SEPARATELY
FACTORY CONTROLS
1. 2.
3. 4.
5. 6.
REMARKS:
FANS TO BE INTERNALLY ISOLATED WITH FACTORY MOUNTED VIBRATION SPRING ISOLATORS
SINGLE POINT POWER, ELECTRICAL TO CONNECT
FACTORY TEMPERATURE BASED ECONOMIZER
FACTORY OUTDOOR AIRFLOW MONITORING STATION
FACTORY COIL COATING FOR ANTI-CORRISION PROTECTION
INTERCONNECT SUPPLY FAN VFD WITH FIRE ALARM PANEL
7. 8.
9. STAND-ALONE, WIRED, PROGRAMMABLE THERMOSTAT CONTROLS
MOUNT ON CONCRETE PAD
FACTORY PROVIDED STAINLESS STEEL CONDENSATE PAN
23 - EXTERIOR LOUVER SCHEDULE
TAG QTY
UNIT
SERVICE TYPE MATERIAL REMARKSMFR MODEL
L-1: 60"x96" 2 GREENHECK EAC-601 2-RELIEF EXTRUDED ALUMINUM COMBINATION LOUVER-DAMPER ALUMINUM 1, 2, 3 L-2: 60"x108" 2 GREENHECK EDD-601 1-INTAKE 6" STATIONARY DRAINABLE BLADE WALL LOUVER ALUMINUM 1, 2 L-3: 72"x48" 1 GREENHECK EDD-601 3 - EXHAUST 6" STATIONARY DRAINABLE BLADE WALL LOUVER ALUMINUM 1, 2
1. 2.
3. REMARKS:
PROVIDE WITH BIRD SCREEN
PAINT TO MATCH EXTERIOR. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR COLORING SCHEME
PROVIDE MOTORIZED DAMPER
23 - AIR TERMINAL SCHEDULE
EQUIPMENT TAG QTY
UNIT
SERVICE TYPE MATERIAL REMARKSMFR MODEL
1 Greenheck Fan
Corp.
EAC-601 Combination Louver/Damper
S-1: 10"ø 10 PRICE SPD 1 - SUPPLY SQUARE PLAQUE DIFFUSER 24"x24"STEEL 1, 2, 3, 4, 5, 6 S-1: 12"ø 1 PRICE SPD 1 - SUPPLY SQUARE PLAQUE DIFFUSER 24"x24"STEEL 1, 2, 3, 4, 5, 6 S-22: 12"x30"10 PRICE HCD 1 - SUPPLY DUCT MOUNTED HIGH CAPACITY DRUM LOUVER DIFFUSER STEEL 1, 2, 3, 4, 5, 6, 7 S-22: 12"x42"10 PRICE HCD 1 - SUPPLY DUCT MOUNTED HIGH CAPACITY DRUM LOUVER DIFFUSER STEEL 1, 2, 3, 4, 5, 6, 7 R-1: 16"x16"5 PRICE 530L 2 - RETURN 45° SINGLE DEFLECTION GRILLE - 24"x24" FACE STEEL 1, 2, 3, 4, 5, 6 R-40: 30"x14"1 PRICE 530L 2 - RETURN 45° SINGLE DEFLECTION GRILLE - SIDEWALL STEEL 1, 2, 3, 4, 5, 6 E-9: 10"ø 6 PRICE 530L 3 - EXHAUST 45° SINGLE DEFLECTION GRILLE 24"x24"ALUMINUM 1, 2, 3, 4, 5, 6 E-10: 6"ø 2 PRICE 530L 3 - EXHAUST 45° SINGLE DEFLECTION GRILLE 12"x12"ALUMINUM 1, 2, 3, 4, 5, 6 E-40: 8"x8"4 PRICE 530L 3 - EXHAUST 45° SINGLE DEFLECTION GRILLE - SIDEWALL STEEL E-41:14"X4"/12"ø 3 PRICE SDGE 3 - EXHAUST EXTRUDED SPIRAL DUCT GRILLE STEEL 1, 2, 3, 4, 5, 6 E-41:14"X4"/18"ø 2 PRICE SDGE 3 - EXHAUST EXTRUDED SPIRAL DUCT GRILLE STEEL 1, 2, 3, 4, 5, 6 T-1: 18"x18"2 PRICE 530L 4 - TRANSFER 45° SINGLE DEFLECTION GRILLE - 24"x24" FACE ALUMINUM 1, 2, 3, 4, 5, 6 T-2: 18"x14"2 PRICE 530L 4 - TRANSFER 45° SINGLE DEFLECTION GRILLE - 24"x12" FACE STEEL 1, 2, 3, 4, 5, 6
1. 2.
3. 4.
5. 6.
7. REMARKS:
CEILING COMPATIBILITY: FURNISH WITH BORDER STYLES COMPATIBLE WITH ADJACENT CEILING SYSTEMS SPECIFICALLY MANUFACTURERED TO FIT INTO CEILING MODULE WITH ACCURATE AND ADEQUATE SUPPORT. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR TYPES OF CEILING SYSTEMS MATERIAL VARIANCE: PROVIDE ALUMINUM GRILLES, REGISTERS, AND DIFFUSERS WHERE INDICATED ABOVE AND IN THE FOLLOWING AREAS- LOCKER ROOMS, RESTROOMS, AND SHOWERS COLOR COMPATIBILITY: PAINT AIR TERMINAL TO MATCH CEILING AND WALLS. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATIONS FOR TYPES OF COLORING SCHEME.
PROVIDE RECTANGULAR TO ROUND ADAPTOR AND VICE VERSA AS REQUIRED
PROVIDE VOLUME DAMPER (AND ACCESS PANEL, IF REQUIRED) AT DUCT BRANCH
CONTRACTOR TO VERIFY EXACT QUANTITIES
PROVIDE OPTIONAL OPPOSED BLADE DAMPER (VCS3)
23 - SILENCER SCHEDULE
TAG SYSTEM NAME MFRMODEL
SIZE
(L"xW"xH")
DESIGN
AIRFLOW
(CFM)
DESIGN
VELOCITY
(FPM)
PRESSURE
DROP
(IN-WG)
INSERTION LOSS
OPERATING
WEIGHT
DETAIL NO.
INSTALL
SPECIFICATION
SECTION REMARKS63 HZ 125 HZ 250 HZ 500 HZ 1000 HZ 2000 HZ 4000 HZ 8000 HZ RDS-1 RA 7,RA 21 PRICE ERM66/9B 66"x30"x56" 9,7001058 0.09 9 13 18 25 28 25 21 18 204 1,2,3,4,5 RDS-2 RA 1,RA 20 PRICE ERM70/7E 70"x26"x36" 4,0006150.10 11 18 27 35 40 34 28 23 185 1,2,3,4,5 SDS-1 SA 7,SA 6 PRICE ERM66/9A 66"x30"x56" 16,000 1371 0.11 7 10 14 21 23 23 19 17 300 1,2,3,4,5 SDS-2 SA 3 PRICE ERM70/7C 70"x26"x36" 7,0001077 0.13 8 13 19 27 32 29 25 21 175 1,2,3,4,5
1. 2.
3. 4.
5. REMARKS:
ELBOW SILENCER
SLIP AND DRIVE DUCT CONNECTION
PERFORATED LINER
NATURAL FIBER ACOUSTIC MEDIA
MASTIC FILLED SEAMS
3. PROVIDE WITH PLAIN BLACK HUB PLATE, NO LOGO
CMMWREF.TVTVCGPRINT
1 1
2 2
345
5 6
6 7
7 8
8 9
9 A A
F F
11 10
10 12
GG
B B
C C
D D
E E
STEM
CLASSROOM
113
STEM
CLASSROOM
112
STAFF
ROOM
102
MEN'S
RESTROOM
106
MECHANICAL
ROOM
103
ELECTRICAL
ROOM
104
IDF
ROOM
105
FAMILY
RESTROOM
108
NURSING
ROOM
116
WOMEN'S
RESTROOM
107
EXHIBIT
SPACE
100
STORAGE
101
ELEVATOR
111
ELEVATOR
MACHINE
ROOM
110
01 M5.01
CU-1
CU-2
FC-2
FC-1
VRF-1
VRF-2
VRF-3
VFC-1
VFC-3
VFC-4
VFC-2
AHU-2
AHU-1
FS-1
17 M5.01
OA
OA
OA
OANANAL-2: 60"x108"
TYP. 2
E-9: 10"ø
TYP. 2300
NANAR-40: 30"x14"
30"x14"
STAFF
RESTROOM
114
OA8"x8"
E-10: 6"ø100
E-10: 6"ø100
E-9: 10"ø250
E-9: 10"ø250
E-9: 10"ø250
E-9: 10"ø250
S-1: 10"ø275
S-1: 10"ø275
NANAR-1: 16"x16"
S-1: 10"ø275
12"ø 16"ø
12"ø
10"ø
10"ø
S-1: 10"ø350
S-1: 10"ø275
S-1: 10"ø275S-1: 10"ø275
NANAR-1: 16"x16"
S-1: 12"ø400
S-1: 10"ø350
NANAR-1: 16"x16"
18"x8"
18"x8"
10"ø
10"ø
48"x10"
14"ø
36"x8"
1"(LINED)
10"ø
14"ø
16"ø
E-41:14"X4"/12"ø200
E-41:14"X4"/12"ø200
E-41:14"X4"/12"ø200
E-41:14"X4"/18"ø200
E-41:14"X4"/18"ø200
12"ø
12"ø
18"ø
18"øE-40: 8"x8"100
44"x30"
56"x30"
S-1: 10"ø275
10"ø
10"øRARA48"x10"
U/C
U/C
U/C
NANAT-1: 18"x18"
NANAT-2: 18"x14"
NANAT-2: 18"x14"
NANAT-1: 18"x18"
18"x14"
1"(LINED)
18"x14"
1"(LINED)
EF-1
24"x20"
14"ø
6"ø
12"ø
M-1201
NANAR-1: 16"x16"
10"ø
M-0005
M-0006
300 CFM
JANITOR'S
ROOM
109
12"ø
10"ø 10"ø
10"ø
E-40: 8"x8"100
6"ø
16"x16"
10"ø
10"ø
NANAR-1: 16"x16"
6"ø 14"ø6"ø6"ø
U/
C U/C
36"x26"
SDS-2
RDS-1
SDS-1
36"x26"
56"x30"
36"x8"
1"(LINED)
RDS-2
M-1101
M-1108
M-1208
450
CFM
450
CFM
S-1: 10"ø275
10"ø 10"ø
10"ø
10"ø
12"ø
M-30
M-40
M-46
M-16
U/C
KEYNOTES
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
11. 12.
PROVIDE ACCESS PANELS IN NON-ACCESSIBLE AREAS (RATED OR NON-RATED MINIMUM 18"X18" SIZE FOR COMBINATION FIRE/SMOKE DAMPERS. INSTALL LARGER ACCESS PANELS FOR LARGER EQUIPMENT AS REQUIRED BY CODE. COORDINATE WITH ARCHITECT FOR APPROVAL OF FINAL LOCATIONS PRIOR TO INSTALLATION. ACCESS PANELS TO BE LOCKING TYPE IN PUBLIC AREAS.
PROVIDE FIRESTOPPING AT PASS THROUGH DUCT PENETRATIONS THROUGH RATED WALLS. DUCTWORK SHALL BE A MINIMUM 26 GA SHEET METAL. COORDINATE WITH OTHER TRADES THAT MAY HAVE PENTRANTS AROUND THE SAME AREA. REFER TO ARCHITECTURAL SHEETS FOR FIRE RATING ASSEMBLIES.
INSULATION MATERIALS APPLIED TO DUCTWORK SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND SMOKE DENSITY NOT EXCEEDING 50 WHEN TESTED AS A COMPOSITE PRODUCT IN ACCORDANCE WITH ASTM E 84 OR UL 723 AND SHALL COMPLY WITH ALL REQUIREMENTS OF THE 2019 CMC SECTION 602.2.
REQUIRED OFFSETS, COMPONENTS, ACCESSORIES, AND FITTINGS MAY NOT BE SHOWN BUT SHALL BE PROVIDED AS REQUIRED TO AVOID INTERFERENCES WITH UNFORESEEN COMPONENTS.
PROVIDE DIELECTRIC UNIONS, GASKETS, AND FASTENERS AT DISSIMILAR METAL CONNECTIONS OF CONTACT POINTS.
REFER TO PLUMBING DRAWINGS FOR CONDENSATE DRAIN PIPE ROUTING.
MAINTAIN A 3'-0" DISTANCE FROM ENVIRONMENTAL EXHAUST OUTLETS (AS DEFINED IN CMC 502.2.1) TO BUILDING OPENINGS AND 10'-0" DISTANCE TO MECHANICALLY FORCED AIR INLET.
FLEXIBLE DUCT CONNECTION TO AIR TERMINAL SHALL BE MAXIMUM 5'-0".
INSTALL DUCT SYSTEMS IN THE FOLLOWING ORDER FROM LOWEST TO HIGHEST REFERENCED FROM THE FINISHED CEILING HEIGHT UNLESS OTHERWISE NOTED:
- SUPPLY DUCT
- RETURN/RELIEF DUCT
- EXHAUST DUCT
COMBINATION FIRE/SMOKE DAMPERS SHALL BE U.L. LABELED AND INSTALLED PER CALIFORNIA'S FIRE MARSHALL MATERIAL LISTING NO. 3225-0981:103 & 0981:104.
DUCT SIZES INDICATED ON PLANS ARE THE "FREE" INSIDE DIMENSION OF THE DUCT. THE CONTRACTOR SHALL INCREASE THE SIZE OF THE DUCT TO ACCOMMODATE ACOUSTICAL AND / OR PERFORATED LINERS. FOR EXAMPLE, A DUCT SIZE SHOWN AS 12"x12" WITH 1" LINER SHALL BE SUPPLIED WITH A 14"x14" DUCT.
ALL DUCTWORK IN EXPOSED CEILING AREAS TO BE PAINTED PER ARCHITECTURAL DIRECTION. SEE ARCHITECTURAL SET FOR COLOR DETAILS.
LEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
FIRST FLOOR
MECHANICAL PLAN
M2.01
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
ITEM DESCRIPTION
M-0005 O/A INTAKE TO TERMINATE IN WALL CAP (WC-18X8, OR SIMILAR) M-0006 O/A INTAKE TO TERMINATE IN WALL CAP (WC-8X8, OR SIMILAR) M-16 30"X14" TRANSFER AIR DUCT. FINISH WITH MASH WIRE. (1100 CFM) M-30 FILTER BOX
M-40 50"X24"X10" MIXING AIR BOX
M-46 FLOW SELECTOR SHALL BE WRAPPED IN THE REMOVABLE SOUND BLANKET M-1101 56"X30" SUPPLY AIR DUCT UP
M-1108 36"X26" SUPPLY AIR DUCT UP
M-1201 30"X44" RETURN AIR DUCT UP
M-1208 36"X26" RETURN AIR DUCT UP
1 1
2 2
3 3
45 5
6 6
7 7
8 8
9 9
A A
F F
11 10
10 12
GG
B B
C C
D D
E E
01 M5.01
CF-2CF-1
OPEN
EXHIBIT
SPACE
200
MD MDNANAL-1: 60"x96"
TYP. 2
17 M5.01
24"ø
24"ø
24"ø
36"x26"SASASASASASASASASASASASASASASASA
SA
SA
SA
SA
50"ø36"ø
S-22: 12"x42"1600(TYP. 10)
(TYP. 10)
S-22: 12"x30"700
M-0002
M-40
RELIEF AIR
L-3: 72"x48"3000
M-1302
M-1102
M-1202
M-1202
M-1102
24"x24"
M-0003
72"x46"
30"x44"
30"x56"
M-29
KEYNOTES
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
11. 12.
PROVIDE ACCESS PANELS IN NON-ACCESSIBLE AREAS (RATED OR NON-RATED MINIMUM 18"X18" SIZE FOR COMBINATION FIRE/SMOKE DAMPERS. INSTALL LARGER ACCESS PANELS FOR LARGER EQUIPMENT AS REQUIRED BY CODE. COORDINATE WITH ARCHITECT FOR APPROVAL OF FINAL LOCATIONS PRIOR TO INSTALLATION. ACCESS PANELS TO BE LOCKING TYPE IN PUBLIC AREAS.
PROVIDE FIRESTOPPING AT PASS THROUGH DUCT PENETRATIONS THROUGH RATED WALLS. DUCTWORK SHALL BE A MINIMUM 26 GA SHEET METAL. COORDINATE WITH OTHER TRADES THAT MAY HAVE PENTRANTS AROUND THE SAME AREA. REFER TO ARCHITECTURAL SHEETS FOR FIRE RATING ASSEMBLIES.
INSULATION MATERIALS APPLIED TO DUCTWORK SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND SMOKE DENSITY NOT EXCEEDING 50 WHEN TESTED AS A COMPOSITE PRODUCT IN ACCORDANCE WITH ASTM E 84 OR UL 723 AND SHALL COMPLY WITH ALL REQUIREMENTS OF THE 2019 CMC SECTION 602.2.
REQUIRED OFFSETS, COMPONENTS, ACCESSORIES, AND FITTINGS MAY NOT BE SHOWN BUT SHALL BE PROVIDED AS REQUIRED TO AVOID INTERFERENCES WITH UNFORESEEN COMPONENTS.
PROVIDE DIELECTRIC UNIONS, GASKETS, AND FASTENERS AT DISSIMILAR METAL CONNECTIONS OF CONTACT POINTS.
REFER TO PLUMBING DRAWINGS FOR CONDENSATE DRAIN PIPE ROUTING.
MAINTAIN A 3'-0" DISTANCE FROM ENVIRONMENTAL EXHAUST OUTLETS (AS DEFINED IN CMC 502.2.1) TO BUILDING OPENINGS AND 10'-0" DISTANCE TO MECHANICALLY FORCED AIR INLET.
FLEXIBLE DUCT CONNECTION TO AIR TERMINAL SHALL BE MAXIMUM 5'-0".
INSTALL DUCT SYSTEMS IN THE FOLLOWING ORDER FROM LOWEST TO HIGHEST REFERENCED FROM THE FINISHED CEILING HEIGHT UNLESS OTHERWISE NOTED:
- SUPPLY DUCT
- RETURN/RELIEF DUCT
- EXHAUST DUCT
COMBINATION FIRE/SMOKE DAMPERS SHALL BE U.L. LABELED AND INSTALLED PER CALIFORNIA'S FIRE MARSHALL MATERIAL LISTING NO. 3225-0981:103 & 0981:104.
DUCT SIZES INDICATED ON PLANS ARE THE "FREE" INSIDE DIMENSION OF THE DUCT. THE CONTRACTOR SHALL INCREASE THE SIZE OF THE DUCT TO ACCOMMODATE ACOUSTICAL AND / OR PERFORATED LINERS. FOR EXAMPLE, A DUCT SIZE SHOWN AS 12"x12" WITH 1" LINER SHALL BE SUPPLIED WITH A 14"x14" DUCT.
ALL DUCTWORK IN EXPOSED CEILING AREAS TO BE PAINTED PER ARCHITECTURAL DIRECTION. SEE ARCHITECTURAL SET FOR COLOR DETAILS.
LEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SECOND FLOOR
MECHANICAL PLAN
M2.02
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
ITEM DESCRIPTION
M-0002 CONTRACTOR TO PROVIDE 1/4" WELDED WIRE MESH OVER RETURN DUCT OPENING,
FASTENED TO MANUFACTURERS DUCT CONNECTION FLANGES
M-0003 12" DEEP PLENUM CONNECTED TO EXHAUST LOUVER
M-29 30"X30" ELEVATOR VENT GREENHECK EAC-601. ASSOCIATED DUCTWORK SHALL BE FIRE WRAPPED.
M-40 50"X24"X10" MIXING AIR BOX
M-1102 SUPPLY AIR DUCT DOWN
M-1202 RETURN AIR DUCT DOWN
M-1302 EXHAUST AIR DUCT DOWN
CMMWREF.TVTVCGPRINT
T
FC-1
T
FC-2
Z
VFC-1
Z
VFC-2
DCDC
DC1
1 2
2 345
5 6
6 7
7 8
8 9
9 A A
F F
11 10
10 12
GG
B B
C C
D D
E E
STEM
CLASSROOM
113
STEM
CLASSROOM
112
STAFF
ROOM
102
MEN'S
RESTROOM
106
MECHANICAL
ROOM
103
ELECTRICAL
ROOM
104
IDF
ROOM
105
FAMILY
RESTROOM
108
NURSING
ROOM
116
WOMEN'S
RESTROOM
107
EXHIBIT
SPACE
100 STORAGE
101
ELEVATOR
111
ELEVATOR
MACHINE
ROOM
110
01 M5.01
FC-1
FC-2
CU-2
CU-1
17 M5.01AHU-2AHU-1
VRF-3
VRF-1
VRF-2
STAFF
RESTROOM
114
VFC-2
VFC-1
FS-1
VFC-4
VFC-3
Z
VFC-4
M-3900
Z
VFC-3
C
C
Z
AHU-1
C
F
HVLS FAN
CONTROLLER
EF-1
M-3900
M-3900
M-3900
M-3900
M-3900
M-3900
M-3900
KEYNOTES
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
ALIGN THERMOSTATS, TEMPERATURE SENSORS, AND CO2 SENSORS (IF APPLICABLE) WITH OTHER WALL DEVICES SUCH AS LIGHT SWITCHES. FIELD COORDINATE WITH OTHER TRADES & OWNERS FF&E PRIOR TO INSTALLATION.
CONTROL THERMOSTATS/SENSORS AND LOW VOLTAGE WIRING IN CONDUITS (LESS THAN 50 VOLTS) SHALL BE FURNISHED, WIRED, AND INSTALLED BY THE ELECTRICAL CONTRACTOR. FIELD COORDINATE EXACT LENGTHS.
PROVIDE ACCESS PANELS IN NON-ACCESSIBLE AREAS (RATED OR NON-RATED) MINIMUM 18"X18" SIZE FOR VALVES, METERS, OR DEVICES REQUIRING MAINTENANCE. INSTALL LARGER ACCESS PANELS FOR LARGER EQUIPMENTAS REQUIRED BY CODE. COORDINATE WITH ARCHITECT FOR APPROVAL OF FINAL LOCATIONS PRIOR TO INSTALLATION.
PROVIDE FIRESTOPPING AT PIPE PENETRATIONS THROUGH RATED WALLS. COORDINATE WITH OTHER TRADES THAT MAY HAVE PENTRANTS AROUND THE SAME AREA. REFER TO ARCHITECTURAL SHEETS FOR FIRE RATING ASSEMBLIES.
INSULATION MATERIALS APPLIED TO PIPING SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND SMOKE DENSITY NOT EXCEEDING 50. REQUIRED OFFSETS, COMPONENTS, ACCESSORIES, AND FITTINGS MAY NOT BE SHOWN BUT SHALL BE PROVIDED AS REQUIRED TO AVOID INTERFERENCES WITH UNFORESEEN COMPONENTS.
PROVIDE DIELECTRIC UNIONS, GASKETS, AND FASTENERS AT DISSIMILAR METAL CONNECTIONS OF CONTACT POINTS.
PROVIDE SEISMIC RATED FLEXIBLE PIPING ACROSS BUILDING SIESMIC JOINTS.
ROUTE MECHANICAL PIPING PARALLEL TO PLUMBING DOMESTIC PIPING TO SHARE TRAPEZE SUPPORTS AS MUCH AS POSSIBLE. REFER TO PLUMBING DRAWINGS FOR REFERENCE.
REFER TO PLUMBING DRAWINGS FOR CONDENSATE POINT OF CONNECTION AND ROUTING.
AUTOMATIC AIR VENTS TO BE PROVIDED AT ALL HIGH POINT LOCATIONS.
LEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
FIRST FLOOR
PIPING & CONTROL
PLAN
M3.01
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
ITEM DESCRIPTION
M-3900 PROVIDE INSULATED REFRIGERANT PIPING LIQUID AND SUCTION LINES. PIPING SIZES
AND FINAL LENGTHS SHALL BE PER MANUFACTURER SPECIFICATION
Z
AHU-2
C
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
11 10
10 12
GG
B B
C C
D D
E E
WALKWAY
VIEWING
GALLERY
202
KEYNOTES
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
ALIGN THERMOSTATS, TEMPERATURE SENSORS, AND CO2 SENSORS (IF APPLICABLE) WITH OTHER WALL DEVICES SUCH AS LIGHT SWITCHES. FIELD COORDINATE WITH OTHER TRADES & OWNERS FF&E PRIOR TO INSTALLATION.
CONTROL THERMOSTATS/SENSORS AND LOW VOLTAGE WIRING IN CONDUITS (LESS THAN 50 VOLTS) SHALL BE FURNISHED, WIRED, AND INSTALLED BY THE ELECTRICAL CONTRACTOR. FIELD COORDINATE EXACT LENGTHS.
PROVIDE ACCESS PANELS IN NON-ACCESSIBLE AREAS (RATED OR NON-RATED) MINIMUM 18"X18" SIZE FOR VALVES, METERS, OR DEVICES REQUIRING MAINTENANCE. INSTALL LARGER ACCESS PANELS FOR LARGER EQUIPMENTAS REQUIRED BY CODE. COORDINATE WITH ARCHITECT FOR APPROVAL OF FINAL LOCATIONS PRIOR TO INSTALLATION.
PROVIDE FIRESTOPPING AT PIPE PENETRATIONS THROUGH RATED WALLS. COORDINATE WITH OTHER TRADES THAT MAY HAVE PENTRANTS AROUND THE SAME AREA. REFER TO ARCHITECTURAL SHEETS FOR FIRE RATING ASSEMBLIES.
INSULATION MATERIALS APPLIED TO PIPING SHALL HAVE A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND SMOKE DENSITY NOT EXCEEDING 50. REQUIRED OFFSETS, COMPONENTS, ACCESSORIES, AND FITTINGS MAY NOT BE SHOWN BUT SHALL BE PROVIDED AS REQUIRED TO AVOID INTERFERENCES WITH UNFORESEEN COMPONENTS.
PROVIDE DIELECTRIC UNIONS, GASKETS, AND FASTENERS AT DISSIMILAR METAL CONNECTIONS OF CONTACT POINTS.
PROVIDE SEISMIC RATED FLEXIBLE PIPING ACROSS BUILDING SIESMIC JOINTS.
ROUTE MECHANICAL PIPING PARALLEL TO PLUMBING DOMESTIC PIPING TO SHARE TRAPEZE SUPPORTS AS MUCH AS POSSIBLE. REFER TO PLUMBING DRAWINGS FOR REFERENCE.
REFER TO PLUMBING DRAWINGS FOR CONDENSATE POINT OF CONNECTION AND ROUTING.
AUTOMATIC AIR VENTS TO BE PROVIDED AT ALL HIGH POINT LOCATIONS.
LEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SECOND FLOOR
PIPING & CONTROL
PLAN
M3.02
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
ITEM DESCRIPTION
778899AABBCCDDEE01- FLO
O
R
0' - 0"01 - FL
O
O
R
0'-0"01 - FL
O
O
R
0' - 0"778899AABBCCDDEE01- FLO
O
R
0' - 0"
01- FLOOR
0' - 0"
02 - MEZZANINE15' - 0"
03 - LOW ROOF
20' - 6"
01 - FLOOR
0'-0"
02 - FLOOR
15'-0"
A
LOW ROOF
20'-6"
B.5
D EC
B.2
B
D.6A.2A.3 D.8
D.9
01 - FLOOR
0' - 0"
MEZZANINE15' - 0"
A B C D ED.9ABCDE
01- FLOOR
0' - 0"
02 - MEZZANINE15' - 0"
03 - LOW ROOF
20' - 6"
A B C D E
17 M5.01
STAFF
ROOM
102
STORAGE
101
MECHANICAL
ROOM
103
OPEN
EXHIBIT
SPACE
200
36"x26"44"x30"56"x30"24"ø 24"ø
S-22: 12"x30"700
(TYP. 5)
AHU-1
VFC-2
FS-1
16"ø
50"x10"36"x26"RARAM-0004
2" REF
2" REF
SDS-1 RDS-1
RDS-2
SDS-2
AHU-2
8"x8"
S-1: 10"ø275 S-1: 10"ø275
R-1: 16"x16"600
56"x30"36"x26"
M-3900
24"x24"
EF-1
01- FLOOR0' - 0"
02 - MEZZANINE15' - 0"
03 - LOW ROOF20' - 6"
01 - FLOOR
0'-0"
02 - FLOOR
15'-0"
9 LOW ROOF
20'-6"
8.9 9
01- FLOOR0' - 0"
02 - MEZZANINE15' - 0"
03 - LOW ROOF20' - 6"
9 01
M5.01
AHU-130"x56"50"ø
24"ø
ELECTRICAL
ROOM
104
MECHANICAL
ROOM
103
OPEN
EXHIBIT
SPACE
200
SDS-1
2" REF
2" REF
M-3900
M-3900
VRF-1
VRF-2
VRF-3
VFC-2
VFC-3
12"ø
18"ø
12"ø
10"ø
10"ø
10"ø
10"ø
14"ø
18"x14"
18"x14"
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SECTION AND
ISOMETRIC VIEWS
M5.01
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING 3/16" = 1'-0"DUCT RISERS - LOOKING EAST 01 3/16" = 1'-0"DUCT RISERS - LOOKING NORTH17 3D VIEW 2 2
T
M
M
H L
M
CT
SF
N.O.
N.O.
DI - SUPPLY FAN STATUS
AI - RETURN AIR TEMP
AI - FILTER DIFFERENTIAL PRESSURE
OA
RA
T AI - ZONE TEMP
SA
AI - SUPPLY AIR TEMP
T
DI - ZONE OVERRIDE
AI - ZONE SETPOINT ADJUST
H L
DI - HIGH STATIC SHUTDOWN
H L
AI - BUILDING STATIC PRESSURE
DO - ENABLE/DISABLE
FILTERAI - OUTSIDE AIR FLOW
C02
AI - ZONE C02 CONCENTRATION
OUTSIDE AIR
MONITORING STATION
SEE 3/M601
DX COIL
INTERNAL UNIT
CONTROLLER
AO - ZONE SETPOINT
AO - ZONE AIR TEMP
DO -ECONOMIZER ENABLE
AO - OUTSIDE AIR DAMPER
(BACNET INTERFACE)
OUTSIDE INSIDE
FIRE ALARM SIGNAL
(HARD-WIRED TO
INTERNAL UNIT
CONTROLLER)
(HARD-WIRED TO SF
AND RF VFD)
OC
DI - ZONE OVERRIDE
DC
DI - OPERABLE CONTACT
(CONTACTS TO BE WIRED AS A
SINGLE INPUT TO THE
CONTROLLER)AI - ECONOMIZER DAMPERS
LPA
N.C.
M
EA
AI - RELIEF DAMPERS
SD DI- UNIT SHUTDOWN
(HARD-WIRED TO FIRE
ALARM PANEL)
•
•
•
•
•
•
ECONOMIZER:
THE ECONOMIZER SHALL BE ENABLED WHENEVER:
OUTSIDE AIR TEMPERATURE IS LESS THAN 70°F (ADJ.).
AND THE OUTSIDE AIR TEMPERATURE IS LESS THAN THE RETURN AIR TEMPERATURE.
AND THE SUPPLY FAN STATUS IS ON.
THE OUTSIDE AIR DAMPERS SHALL OPEN WHILE THE RETURN AIR DAMPER SHALL CLOSE DURING THE FULL ECONOMIZER MODE THE ECONOMIZER SHALL CLOSE WHENEVER:
MIXED AIR TEMPERATURE DROPS TO 60°F (ADJ.).
OR ON LOSS OF SUPPLY FAN STATUS.
THE OUTSIDE AIR AND REMOTE RELIEF AIR DAMPERS SHALL CLOSE AND THE RETURN AIR DAMPER SHALL OPEN WHEN THE UNIT IS OFF.
OUTSIDE AIR FLOW RATE:
THE CONTROLLER SHALL MEASURE THE OUTSIDE AIR FLOW RATE AND MODULATE THE OUTSIDE AIR DAMPER TO MAINTAIN THE OSA SETPOINT. THE MINIMUM OSA SETPOINT (ADJ.) DURING OCCUPIED HOURS SHALL BE AS SCHEDULED ON THE DRAWINGS.
OUTSIDE AIR VENTILATION - CARBON DIOXIDE (CO2) CONTROL:
THE OSA SETPOINT SHALL BE RESET BASED ON THE ZONE CO2 CONCENTRATION. IF THE ZONE CO2 CONCENTRATION IS FROM 50-100% CONTROL LOOP SIGNAL (I.E. ZONE CO2; 250 TO 500 PPM (ADJ.) ABOVE THE ZONE CO2 SETPOINT) THE OSA SETPOINT SHALL BE RESET PROPORTIONALLY UP TO THE OSA MAXIMUM SETPOINT.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
HIGH ZONE CO2 CONCENTRATION: IF THE HIGHEST ZONE CO2 CONCENTRATION IS GREATER THAN 1200 PPM (ADJ.).
FILTER DIFFERENTIAL PRESSURE MONITOR:
THE CONTROLLER SHALL MONITOR THE DIFFERENTIAL PRESSURE ACROSS THE AHU FILTER..
ALARMS SHALL BE PROVIDED AS FOLLOWS:
· FILTER CHANGE REQUIRED: FILTER DIFFERENTIAL PRESSURE EXCEEDS 1.25 IN WG (ADJ.).
RETURN AIR TEMPERATURE:
THE CONTROLLER SHALL MONITOR THE RETURN AIR TEMPERATURE.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
· HIGH RETURN AIR TEMP: RETURN AIR TEMPERATURE IS GREATER THAN 90°F (ADJ.). · LOW RETURN AIR TEMP: RETURN AIR TEMPERATURE IS LESS THAN 50°F (ADJ.).
SUPPLY AIR TEMPERATURE:
THE CONTROLLER SHALL MONITOR THE SUPPLY AIR TEMPERATURE.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
· HIGH SUPPLY TEMP: SUPPLY AIR TEMP IS 5°F (ADJ.) GREATER THAN SETPOINT. . LOW SUPPLY TEMP: SUPPLY AIR TEMP IS LESS THAN 48°F (ADJ.) VRF
CONTROLLER
DO - ENABLE/DISABLE
AO - ZONE SETPOINT
AO - ZONE AIR TEMP
DO -ECONOMIZER ENABLE
AO - OUTSIDE AIR DAMPER
(BACNET INTERFACE)
•
•
•
•
•
•
•
•
•
•
•
•
•
•
RUN CONDITIONS - SCHEDULED:
THE AIR HANDLING UNIT SHALL BE CONTROLLED BY A FACTORY INSTALLED CONTROLLER PROVIDED BY THE EQUIPMENT MANUFACTURER.
RUN CONDITIONS - SCHEDULED:
THE AHU SHALL RUN BASED UPON AN OPERATOR ADJUSTABLE SCHEDULE. · 7 DAYS A WEEK: 8:00 AM TO 6:00 PM (ADJ.)
· HOLIDAYS: OFF (ADJ.)
RUN CONDITIONS - ON-HOURS MODE:
WHEN THE AHU IS SCHEDULED "ON" THE UNIT SHALL MAINTAIN:
75°F (ADJ.) COOLING SETPOINT
70°F (ADJ.) HEATING SETPOINT
RUN CONDITIONS - OFF-HOURS SETBACK MODE:
WHEN THE AHU IS SCHEDULED "OFF" THE UNIT SHALL MAINTAIN:
85°F (ADJ.) COOLING SETPOINT
60°F (ADJ.) HEATING SETPOINT
RUN CONDITIONS - DEMAND SHED SETBACK MODE:
WHEN DEMAND SHED MODE IS TRIGGERED THE UNIT SHALL CONDUCT A CENTRALIZED DEMAND SHED TO MAINTAIN THE FOLLOWING TEMPERATURES:
80°F (ADJ.) COOLING SETPOINT
65°F (ADJ.) HEATING SETPOINT
CONTROLS SHALL BE CAPABLE OF BEING REMOTELY RESET TO ORIGINAL SET POINTS.
CONTROLS SHALL HAVE THE FOLLOWING FEATURES:
DISABLED (BY AUTHORIZED FACILITIES OPERATOR)
AUTOMATIC DEMAND SHED CONTROL. UPON RECEIPT OF DEMAND RESPONSE SIGNAL, UNIT SHALL RUN DEMAND SHED OPERATION RUN CONDITIONS - WINDOW - DOOR OPEN SETBACK MODE:
WHEN AHU IS OPERATING AND ZONE DOOR STATUS IS OPEN, THE UNIT SHALL MAINTAIN 82°F (ADJ.) COOLING SETPOINT
64°F (ADJ.) HEATING SETPOINT
ZONE SETPOINT ADJUSTMENT:
THE OCCUPANT SHALL BE ABLE TO ADJUST THE ZONE TEMPERATURE SETPOINT BY UP TO +/-2°F (ADJ.).
EMERGENCY UNIT SHUTDOWN:
THE UNIT SHALL SHUT DOWN UPON DETECTION OF SMOKE AND GENERATE A SUPERVISORY SIGNAL TO THE FIRE ALARM PANEL. SMOKE DETECTOR SHALL BE HARD- WIRED TO THE FIRE ALARM PANEL.
OPTIMAL START:
IF IN 1-HOUR (ADJ.) PRIOR TO SCHEDULED OPERATION, THE ZONE TEMPERATURE IS LESS THAN 60°F (ADJ.) OR GREATER THAN 80°F (ADJ.), THE UNIT SHALL OPERATE IN WARM-UP/COOL DOWN MODE FOR 1-HOUR (ADJ.). IN WARM-UP/COOL DOWN MODE, THE OUTSIDE AIR DAMPER SHALL BE CLOSED AND THE SUPPLY AIR DAMPER AND RETURN AIR DAMPER SHALL BE OPEN.
BUILDING STATIC PRESSURE CONTROL:
THE CONTROLLER SHALL MEASURE BUILDING STATIC PRESSURE AND MODULATE THE POWER EXHAUST FAN VFD SPEED TO MAINTAIN THE BUILDING STATIC PRESSURE SETPOINT OF 0.02 IN WG (ADJ.).
ALARMS SHALL BE PROVIDED AS FOLLOWS:
· HIGH BUILDING STATIC PRESSURE: BUILDING STATIC PRESSURE IS 100% (ADJ.) GREATER THAN SETPOINT. · LOW BUILDING STATIC PRESSURE: BUILDING STATIC PRESSURE IS 0.00 IN WG (ADJ.) OR LESS.
SUPPLY FAN:
THE SUPPLY FAN SHALL RUN ANYTIME THE AHU IS SCHEDULED TO RUN, UNLESS SHUTDOWN ON SAFETIES. TO PREVENT SHORT CYCLING, THE SUPPLY FAN SHALL HAVE A 10 MINUTE (ADJ.) MINIMUM RUNTIME.
WHEN ZONE TEMPERATURE IS GREATER THAN ITS COOLING SETPOINT, FROM 0-100% CONTROL LOOP SIGNAL (IE ZONE TEMPERATURE 0°F TO 2°F (ADJ.) ABOVE THE COOLING SETPOINT) THE SUPPLY FAN SHALL MODULATE BETWEEN THE TWO STAGES (50-100% (ADJ.)).
SUPPLY FAN VFD SPEED SHALL NOT DROP BELOW 40% (ADJ.)
WHEN THE ZONE TEMPERATURE IS BETWEEN THE COOLING SETPOINT AND THE HEATING SETPOINT, THE SUPPLY FAN SHALL MAINTAIN THE MINIMUM FAN VFD SPEED OF 40% (ADJ.).
WHEN ZONE TEMPERATURE IS LESS THAN ITS HEATING SETPOINT, FROM 0-100% CONTROL LOOP SIGNAL (IE ZONE TEMPERATURE 0°F TO 2°F (ADJ.) BELOW THE HEATING SETPOINT) THE SUPPLY FAN SHALL MODULATE BETWEEN THE TWO STAGES (50-100% (ADJ.)).
COOLING STAGES / MODULATION:
THE CONTROLLER SHALL MONITOR THE ZONE TEMPERATURE AND STAGE/MODULATE THE REMOTE VRF'S COMPRESSORS TO MAINTAIN THE ZONE TEMPERATURE SETPOINT.
IF APPLICABLE, TO PREVENT SHORT CYCLING, THERE SHALL BE A DELAY BETWEEN STAGES AND EACH STAGE SHALL HAVE A MINIMUM RUNTIME AS RECOMMENDED BY
THE MANUFACTURER
COOLING SHALL BE ENABLED WHENEVER:
OUTSIDE AIR TEMPERATURE IS GREATER THAN 60°F (ADJ.)
AND THE SUPPLY FAN STATUS IS ON
HEATING STAGES / MODULATION:
THE CONTROLLER SHALL MONITOR THE ZONE TEMPERATURE AND STAGE/MODULATE THE REMOTE VRF'S COMPRESSORS TO MAINTAIN THE ZONE TEMPERATURE SETPOINT.
IF APPLICABLE, TO PREVENT SHORT CYCLING, THERE SHALL BE A DELAY BETWEEN STAGES AND EACH STAGE SHALL HAVE A MINIMUM RUNTIME AS RECOMMENDED BY
THE MANUFACTURER
HEATING SHALL BE ENABLED WHENEVER:
OUTSIDE AIR TEMPERATURE IS LESS THAN 60°F (ADJ.)
AND THE SUPPLY FAN STATUS IS ON
VRF CONDENSING
UNIT
•
•
•
•
•
SEQUENCE OF OPERATION
RUN CONDITIONS - 24/7 OPERATION:
THE SYSTEM SHALL OPERATE CONTINUOUSLY TO MAINTAIN THE FOLLOWING TEMPERATURES IN EACH ZONE:
76°F (ADJ.) COOLING SETPOINT
70°F (ADJ.) HEATING SETPOINT
ZONE SETPOINT ADJUST:
THE OCCUPANT SHALL BE ABLE TO ADJUST THE ZONE TEMPERATURE HEATING AND COOLING SETPOINTS AT THE ZONE SENSOR BY UP TO +/- 2°F (ADJ.).
THE DDC SYSTEM SHALL MONITOR TEMPERATURE AND PROVIDE ALARM FOR THE UNIT.
ALARMS SHALL BE PROVIDED AS FOLLOWS:
HIGH ZONE TEMP: IF THE ZONE TEMPERATURE IS GREATER THAN 80°F (ADJ.) LOW ZONE TEMP: IF THE ZONE TEMPERATURE IS LESS THAN 60°F (ADJ.) IF ZONE CO2 CONCENTRATION IS ABOVE 1500PPM (ADJ.) (FOR ZONES WITH CO2 SENSORS)
SA
ZONE SETPOINT ADJUST
T
OUTDOOR
UNIT
INDOOR UNIT (TYP.)
HRU BOX
(TYP.)
CO2AI - ZONE CO2 PPM
(IF APPLICABLE)
•
•
SEQUENCE OF OPERATION
RUN CONDITIONS - SCHEDULED:
THE SPLIT SYSTEMS SHALL RUN BASED UPON AN OPERATOR ADJUSTABLE SCHEDULE.
· 7 DAYS A WEEK: 8:00 AM TO 6:00 PM (ADJ.)
· HOLIDAYS: OFF (ADJ.)
RUN CONDITIONS - ON-HOURS MODE:
WHEN THE FAN COIL IS SCHEDULED "ON" THE UNIT SHALL MAINTAIN:
75°F (ADJ.) COOLING SETPOINT
70°F (ADJ.) HEATING SETPOINT
RUN CONDITIONS - OFF-HOURS MODE:
THE UNIT SHALL NOT BE ENABLED IN OFF HOURS MODE.
WHEN COMMANDED ON AT THE OCCUPANT LEVEL THE SYSTEM SHALL BE ENABLED AND RUN PER THE 'ON-HOURS MODE' FOR A DURATION OF 3 HRS. (ADJ.) SA
ZONE SETPOINT ADJUST
T
OUTDOOR UNIT
INDOOR UNIT
LPA
THE FAN SHALL RUN DURING SCHEDULED TIME (ADJ.)
SCHEDULE SWITCH (START/STOP)
EA
M
S
LPA
T
H
OUTSIDE AIR CONDITIONS:
THE CONTROLLER SHALL MONITOR THE OUTSIDE AIR
TEMPERATURE (F) AND HUMIDITY (%RH) AND
CALCULATE THE OUTSIDE AIR ENTHALPY ON A
CONTINUAL BASIS. THESE VALUES SHALL BE MADE
AVAILABLE TO THE SYSTEM AT ALL TIMES.
OUTSIDE AIR TEMPERATURE HISTORY:
THE CONTROLLER SHALL MONITOR AND RECORD THE
HIGH AND LOW TEMPERATURE READINGS FOR THE
OUTSIDE AIR. THESE READINGS SHALL BE RECORDED
ON A DAILY, MONTH-TO-DATE, AND YEAR-TO-DATE
BASIS.
AI - OUTSIDE AIR
TEMPERATURE
AI - OUTSIDE AIR
HUMIDITY
REFER TO SHEET MX.XX FOR
LOCATION
LPA
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
MECHANICAL
CONTROL
SEQUENCES AND
DIAGRAMS
M6.00
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNTSSINGLE ZONE VAV HVAC UNIT WITH DX COIL 01 NTSVRF FAN COIL UNIT, 24/7 OPERATION17
NTSSPLIT SYSTEM COOLING UNIT18
NTSEXHAUST FAN, LINE VOLTAGE SCHEDULED SWITCH19
NTSAMBIENT CLIMATE MONITORING, DDC20
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
MECHANICAL
CONTROL
SEQUENCES AND
DIAGRAMS Copy 1
M6.01
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING
1 8
3 4
5 7
911
CUSTOM AIR HANDLING UNIT
OUTSIDE AIR LOUVER
VERTICAL INTERNALLY LINED SUPPLY AND
RETURN AIR DUCTWORK, PROVIDE
FLEXIBLE CONNECTION AT UNIT
(SEE NOTE #3)
ACCESS DOOR
DX COIL
FILTER SECTION
1. 2.
3. NOTE:
SEE STRUCTURAL DETAIL FOR PLATFORM AND ANCHORAGE DETAILS.
SEE PLUMBING DRAWING P2.01 FOR ROUTING AND SIZES.
SEE DUCT INSULATION SCHEDULE ON DRAWING M0.20 FOR MATERIAL AND THICKNESS REQUIREMENTS.
CONCRETE HOUSEKEEPING PAD
(SEE NOTE #1)
1 2
3 4
5 6
7 8
FINISHED FLOOR
CONDENSATE DRAIN PIPING CONNECTION
(SEE NOTE #2)
9 10
11 SIDE VIEW BOLT THRU PAD (SEE NOTE #1)12
FLEXIBLE CONNECTION13RASA6
2 SUPPLY FAN SECTION
ASSEMBLE UNIT SECTIONS ON C-CHANNEL
BASE. WELD IN PLACE. TYPICAL PER SECTION
10 1
3 7 9
FRONT VIEWSA 10
2 OA
12 13
TYP.
5 6
7 ELECTRICAL INLETS
REFRIGERANT PIPING, ROUTING PER
PLANS SIZE PER MANUFACTURER'S
RECOMMENDATIONS
CONDENSING UNIT (MAX WEIGHT 700 LBS)
NEOPRENE ISOLATOR PADS, MODEL
SUPER W MASONWEST OR EQUAL
6" MINIMUM
LEVEL CONCRETE PAD (SEE NOTE #1)
1. NOTE:
SEE STRUCTURAL DETAIL FOR PLATFORM AND ANCHORAGE DETAILS.
FINISHED GRADE
ANCHORAGE TABS INTEGRAL TO
CONDENSING UNIT. BOLT THRU TAB AND
ISOLATOR PAD TO CONCRETE.
1 2
3 4
5 6
7 8
(TYP)
(TYP. 4)
1 2
3 4
8 ELECTRICAL INLETS
REFRIGERANT PIPING, ROUTING PER
PLANS SIZE PER MANUFACTURER'S
RECOMMENDATIONS
CONDENSING UNIT (MAX WEIGHT 250 LBS)
NEOPRENE ISOLATOR PADS, MODEL
SUPER W MASONWEST, OR EQUAL
6" MINIMUM
LEVEL CONCRETE PAD
(SEE NOTE #1)
1. NOTE:
SEE STRUCTURAL DETAIL FOR PLATFORM AND ANCHORAGE DETAILS.
FINISHED GRADE
ANCHORAGE TABS INTEGRAL TO
CONDENSING UNIT. BOLT THRU TAB AND
ISOLATOR PAD TO CONCRETE
1 2
3 4
5 6
7 8
(TYP)
(TYP. 4)
1 2
3 4
6 7
8 5
1 ROOF OR STRUCTURE ABOVE
MASON TYPE 30N SPRING HANGER (SEE
NOTE #1)
MASON TYPE SCB SEISMIC BRACKET (SEE
NOTE #1)
SNUBBER PLATE (UP STOP)
MASON TYPE SCBH SEISMIC BRACKET
MASON TYPE SRC OR UC STIFFENER AND
ROD CLAMPS (SEE NOTE #1)
1. 2.
NOTE:
SEE STRUCTURAL DETAIL FOR UPPER ATTACHMENT DETAILS.
PROVIDE SEISMIC BRACING AS REQUIRED BY THE CBC AND ASCE STANDARDS 7-10, SECTION 13.6.7. RODS, TRAPEZE HANGERS, STRAPS, BANDS, DUCT SPACING, ETC. SHALL BE SIZED PER THE CURRENT EDITION OF SMACNA SEISMIC RESTRAINT MANUAL.
1 2
3 4
5 6
SUSPENDED EQUIPMENT
IF DIMENSION EXCEEDS 50 TIMES THE
DIAMETER OF THE ROD, THEN A VERTICAL
STIFFENER IS REQUIRED
PRESTRETCHED STEEL AIRCRAFT CABLE
7 8
9 ELEVATION
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
(TYP)
PLAN VIEW
1 2
3 4
5 6
7 8
3 7
69
45°45°250# MAX
1 2
3 45
3 (TYP.)
FAN MOUNTING PLATE WITH FACTORY
PROVIDED I-BEAM MOUNTING KIT
1/4" CABLE 1:1 SLOPE, IN 4 DIRECTIONS
(SEE NOTE #1)
CIRCULATING FAN
STRUCTURE ABOVE
EXTENSION ARM
1. NOTE:
SEE STRUCTURAL DETAIL FOR UPPER ATTACHMENT DETAIL.
1 2
3 4
5 (TYP)
1 23456
NEGATIVE PRESSURE DUCT SIZE PER
PLAN
FLEXIBLE CONNECTION
ROOF OR STRUCTURE ABOVE
EXHAUST FAN (SEE NOTE #1)
POSITIVE PRESSURE DUCT SIZE PER PLAN
CEILING
1. 2.
NOTE:
SEE STRUCTURAL DETAIL FOR UPPER ATTACHMENT DETAILS.
PROVIDE SEISMIC BRACING AS REQUIRED BY THE CBC AND ASCE STANDARDS 7-10, SECTION 13.6.7. RODS, TRAPEZE HANGERS, STRAPS, BANDS, DUCT SPACING, ETC. SHALL BE SIZED PER THE CURRENT EDITION OF SMACNA SEISMIC RESTRAINT MANUAL.
1 2
3 4
5 645°FRONT
REAR
4" MIN.12" MIN.
18" MIN. FROM ROOF STRUCTURE
TOP OF STRUCTURE
1 2
3 4
MAX UNIT SIZE: 39"x14"x9"
MAX UNIT WEIGHT: 35 LBS
SIDE
18" MAX.
3 5
SECURE FACTORY MOUNTING BRACKET
TO WALL. SEE STRUCTURAL TYPICAL WALL
MOUNTED DETAIL
KNOCKOUT FOR REFRIGERANT, DRAIN,
POWER AND SIGNAL LINES
UNIT OUTLINE
WALL MOUNTED CONDENSATE PUMP
(SEE NOTE #4)
1. 2.
3. 4.
NOTE:
CLEARANCES OF 18" ON TOP OF AND TO THE LEFT OF THE FAN COIL UNIT ARE ABSOLUTE MINIMINUM CLEARANCES AROUND UNIT FROM ANY OBSTRUCTIONS.
REFRIGERANT IS METERED BY CAPILLARY TUBES IN THE OUTDOOR UNIT. INSULATE BOTH REFRIGERANT LINES.
REFRIGERANT, DRAIN, AND POWER CONNECTIONS TO BE MADE IN THE REAR OF THE UNIT.
WALL MOUNTED CONDENSATE PUMP FOR DUCTLESS FAN COIL UNITS SHALL HAVE SEPARATE 120V CONNECTION FOR PUMP.
WALL ANCHORS. SEE STRUCTURAL DETAIL
1 2
3 4
5 BLOCKING PLATE 6
1/4-14 HILTI KWIK-FLEX SCREWS (ICC
ESR-3332)
7 7
6 1ANCHOR BOLT (SEE NOTE #1)
STEEL WASHER
EQUIPMENT SUPPORT PER MANUF.
NEOPRENE GROMMET
NEOPRENE RIBBED PAD (5/16" MIN.)
LOAD DISTRIBUTING PLATE (3/16" MIN.
STEEL)
1. NOTE:
SEE STRUCTURAL DETAIL FOR PLATFORM AND ANCHORAGE DETAILS. 1 2
3 4
5 6
2 3
5 4
(TYP)
4 1
2 3
WELDED METAL FASTENERS 12" ON
CENTER MAX. BOTH DIRECTIONS, 2" FROM
EDGES
ALL ENDS OF LINER TO BE COATED WITH
ADHESIVE ("BUTIERED"), ENDS OF LINER
SHALL BE BUTTED FIRMLY TOGETHER NO
EXPOSED INSULATION SHALL BE VISIBLE
INTERNAL DUCT LINER (SEE NOTE #2)
SHEET METAL DUCT
1. 2.
NOTE:
LINER TO BE ADHERED TO DUCT WITH ADHESIVE.
SEE DUCT INSULATION SCHEDULE ON M0.20 FOR MATERIAL AND THICKNESS REQUIREMENTS. 1 2
3 4
LOCKING QUADRANT VOLUME DAMPER
1/3W, 6" MINIMUM
SHEET METAL DUCT AS SPECIFIED
CONICAL TAP
MAIN DUCT
1 2
3 4
5 1.
NOTE:
LATERAL TAKE-OFF
UNLESS OTHERWISE
NOTED ON PLANS.
RETURN/EXHAUST
AIR FLOW
AIR FLOW
SUPPLYFLOWAIR1
2 3
4 5
W45°D
LOCKING QUADRANT VOLUME DAMPER
LATERAL TAP
SHEET METAL DUCT AS SPECIFIED
MAIN DUCT
INSIDE RADIUS = DIAMETER
TRANSITION
1 2
3 4
5 6
FLOW
AIRFLOWAIR1
2 3
4 5
6 1.
NOTE:
LATERAL TAKE-OFF
UNLESS OTHERWISE
NOTED ON PLANS.45°D
DUCTWORK WITH CROSS
SECTIONAL AREA GREATER
THAN 6.0 SQUARE FEET1.
2. NOTE:
SEE STRUCTURAL DETAIL FOR UPPER ATTACHMENT DETAIL.
PROVIDE SEISMIC BRACING AS REQUIRED BY THE CBC AND ASCE STANDARDS 7-10, SECTION 13.6.7. RODS, TRAPEZE HANGERS, STRAPS, BANDS, DUCT SPACING, ETC. SHALL BE SIZED PER THE CURRENT EDITION OF SMACNA SEISMIC RESTRAINT MANUAL.
(TYP)(TYP)
(TYP)
(TYP)(TYP)
1 5910
67 8
27 RECTANGULAR DUCT
LOAD RATED FASTENER
ROUND DUCT
SHEET METAL SCREW
SECURE TO STRUCTURE ABOVE (SEE
NOTE # 1 AND #2)
1" x 22 GA. METAL STRAP
THREADED ROD
1 2
3 4
5 6
7 DOUBLE NUT
TRAPEZE HANGER
RIGID SEISMIC BRACE. AIR CRAFT CABLE
ON BOTH SIDES CAN BE USED IN LIEU OF A
RIGID SEISMIC BRACE. (SEE NOTE #2)
8 9
10 (TYP)
(TYP)
4 526
3 6
1 5
(TYP)
6 1
2 3
15° MIN
2 INTERIOREXTERIOR
SECTION
PLAN
4 LOUVER
DUCT. SEE FLOOR PLANS FOR SIZE.
PLENUM BOX
EXTERIOR WALL (SEE NOTE #1)
1. 2.
NOTE:
SEE FLOOR PLANS
AND SPECIFICATION
FOR LOUVER SIZE
AND SCHEDULE FOR
MATERIAL.
CONNECTION TO
BOTTOM OR TOP OF
PLENUM BOX
SIMILAR.
12" MIN
1 2
3 4
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
MECHANICAL
DETAILS AND
DIAGRAMS
M7.00
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNTSAHU-1 & 2 ON CONCRETE PAD W/ RIGID CURB 01 NTSCONDENSING UNIT ON CONCRETE PAD ON GRADE 02
NTSSMALL CONDENSING UNIT ON CONCRETE PAD ON GRADE 03
NTSSUSPENDED EQUIPMENT MOUNTING 04
NTSCIRCULATING FAN SUPPORT 10
NTSINLINE EXHAUST FAN 11
NTSWALL MOUNTED FAN COIL IN METAL STUD DETAIL 12
NTSNEOPRENE PAD ISOLATOR17
NTSACOUSTICAL DUCT LINER18
NTSRECTANGULAR TO ROUND
DUCT TAKEOFF13
NTSROUND DUCT TAKEOFF14
NTSTYPICAL DUCT SUPPORT19
NTSEXT. LOUVER-DUCT CONNECTION20
SIDE VIEW
FRONT VIEW
21 FRONT VIEW
TOP VIEW
1 2
MAIN OR BRANCH SUPPLY DUCT
PROVIDE GRILLE EACH SIDE OF DUCT
WHERE INDICATED ON PLANS
SUPPLY AIR GRILLE. SINGLE OR DOUBLE-
DEFLECTION VANES. SEE AIR TERMINAL
SCHEDULE FOR TYPE
3 1
2 3
1 2 3
1 2
3 4
4 7
6" MIN.
6" MIN.
1. 2.
3. NOTE:
SEE STRUCTURAL DETAIL FOR UPPER
ATTACHMENT.
CEILING GRILLE BOOT DIMENSION SHALL
BE EQUAL TO THE TRANSFER AIR GRILLE.
BOOT HEIGHT SHALL BE EQUAL TO 12". FOR
RETURN BOOT DIMENSIONS, REFER TO
MECHANICAL FLOOR PLANS.
SEE DUCT INSULATION SCHEDULE ON
M0.20 FOR MATERIAL AND THICKNESS
REQUIREMENTS.
OPENING SHALL BE 8" MINIMUM FROM
STRUCTURAL
5 WIRED MESH SCREEN AT TERMINATION
HANGER STRAP SECURE TO STRUCTURE
ABOVE,ATTACH STRAP WITH 2 - #12 SMS
(SEE NOTE #1)
INTERNALLY LINED SHEET METAL SOUND
BOOT (SEE NOTES #2 & #3)
1 RETURN BOOT
CEILING
3 1
2 3
4 5
6 22 6
H=12" MIN
(TYP)
(TYP)
3 2
4 1 5
INTERNALLY LINED SHEET METAL BOX
(SEE NOTE #3)
HANGER STRAP SECURE TO STRUCTURE
ABOVE (SEE NOTE #1)
TRANSFER AIR GRILLE, SEE FLOOR PLANS
FOR SIZE
CEILING
ATTACH STRAP WITH 2 -
#12 SMS
TYPICAL WALL
6 (TYP)
1 2
3 4
5 6
2 3
12 5
6 7108
9 11 INSULATED FLEXIBLE DUCT INSTALLED
WITH INNER DUCT STRETCHED TAUT
(TAKE UP SLACK)
1-1/2" X 18 GA. SHEETMETAL HANGER
STRAP EVERY 8'-0" & AT TURN IN
DIRECTION. SECURE STRAP TO
STRUCTURE ABOVE (SEE NOTE #1)
FLEX DUCT
DUCT COLLAR (SEE NOTE #3)
3/8" BAND ON DUCT COLLARS (TYP)
ROUND DUCT
FACTORY MOUNTED SHEET METAL INLET
COLLAR SECURE WITH CLAMPING DEVICE
1-1/2" x 22 GA SHEETMETAL STRAP
SECURE TO STRUCTURE ABOVE (SEE
NOTES #1 & #2)
CEILING
LOCKING QUADRANT VOLUME DAMPER
SECURE WIRE TO STRUCTURE ABOVE
(SEE NOTE #2)
1 2
3 4
5 6
7 8
9 10
11 12
2. 3.
4. NOTE:
1. FOR UPPER ATTACHMENT TO STEEL STRUCTURE, AND FOR STEEL STRUCTURE BRACING REQUIREMENTS TO STRUCTURE DETAILS.
PULL BACK JACKET & INSULATION FROM CORE DUCT COLLECT EXCESS INNER DUCT PAST COLLAR BEAD
UNTIL FULLY STRETCHED, THEN WRAP AT LEAST TWICE AROUND WITH APPROVED TAPE AND SECURE WITH APPROVED CLAMP. PULL JACKET & INSULATION BACK OVER THE CORE. SECURE JACKET WITH TWO WRAPS OF TAPE OR AN APPROVED CLAMP. TUCK IN EDGE OF JACKET OR TAPE. FIBERS SHALL NOT BE EXPOSED. FACTORY FLEX DUCT METAL COLLARS MAY BE USED FOR RIGIND CONNECTIONS IN LIEU OF BANDS.
CEILING MOUNTED AIR TERMINALS WEIGHING LESS THAN OR EQUAL TO 20 LBS SHALL HAVE ONE (1) #12 GA.
SLACK SAFETY WIRE ATTACHED FROM THE TERMINAL TO THE STRUCTURE ABOVE.
IF GRILLE IS LESS THAN OR EQUAL TO 56 LBS, PROVIDE TWO #12 GAGE SLACK SAFETY WIRES AT DIAGONAL CORNERS. IF DIFFUSER IS MORE THAN 56 LBS, PROVIDE INDEPENDENT SUPPORT USING 4 TAUT #12 GAGE WIRES, ONE AT EACH CORNER, ATTACHED TO STRUCTURE ABOVE. 1 1" 20 GAGE DUCT STRAP ONE PER SIDE (4
TOTAL). ATTACH TO GRID WITH 2 #8 SM
SCREWS. PROVIDE RUBBER WASHER
WHEN TAPPING INTO AIR TERMINAL
DEVICE
13 4
13 1
2 3
4 5
6 COVER
1. 2.
3. NOTE:
COORDINATE EXACT LOCATION OF WALL MOUNTED CONCEALED REGULATOR WITH ARCHITECT PRIOR TO INSTALLATION.
THE ELECTRONIC AND REMOTE CONTROL SYSTEM IS DESIGNED TO BE IMBEDDED IN THE WALL WITH THE FINISHED SURFACE.
OPERATION TO BE ADJUSTABLE USING HAND HELD REMOTE.
UNIVERSAL DRIVE DAMPER
PLENUM RATED WIRE WITH FEMALE DC
POWER CONNECTOR
ROUND DAMPER OR RECTANGULAR
SINGLE BLADE DAMPER
1 2
3 4
5 EIGHT CONNECTOR WALL PLATE
INTERFACE WITH COVER
6 MOTOR CONTROL MODULE AND WIRE
TETHER
FINISHED WALL
*PROVIDE MIN. 30"x48" CLEAR FLOOR SPACE FOR
PERPENDICULAR APPROACH AT EACH LOCATION.
12"
48"
4"
DOOR JAMB
STRIKE SIDE OF JAMB
THERMOSTAT OR ZONE TEMPERATURE SENSOR
CARBON DIOXIDE OR OTHER ZONE SENSOR
TOP OF STAT, SWITCH, SENSOR, ETC.
FINISHED FLOOR
1 2
3 4
5 6
1 2
3 4
5 6
24" MAX
34" MAX46" MAX SIDE APPROACHFINISHED
FLOOR
WALL
THERMOSTAT
OR ZONE
TEMPERATURE
SENSOR
44" MAX FRONT APPROACH(IF COUNTER WITH KNEE SPACE PER CBC 11A-1I)TOP OF
THERMOSTAT,
SWITCH, OUTLET,
CONTROL
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
MECHANICAL
DETAILS AND
DIAGRAMS
M7.01
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNTSDUCT MOUNTED GRILLE 01 NTSCEILING RETURN AND TRANSFER AIR PLENUM OR GRILLE 02
NTSDIFFUSER CONNECTION 03
NTSCONCEALED ELECTRONIC REGULATOR CABLE SYSTEM DETAIL 04 NTSTHERMOSTAT MOUNTING HEIGHT DETAIL10
NTSTHERMOSTAT MOUNTING OVER OBSTRUCTION 09
1. ALL CONSTRUCTION AND MATERIALS SHALL BE AS SPECIFIED AND IN
ACCORDANCE WITH ALL APPLICABLE CODES, ORDINANCES, LAWS, PERMITS, AND THE CONTRACT DOCUMENTS.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE ACCURATE PLACEMENT OF ALL NEW CONSTRUCTION ON THE SITE.
3. THE CONTRACTOR SHALL VERIFY ALL SITE CONDITIONS AND DIMENSIONS,
AND EXACT LOCATIONS AND ELEVATIONS OF PIPING BEFORE STARTING WORK. SHOULD A DISCREPANCY APPEAR IN THE CONTRACT DOCUMENTS, OR
BETWEEN THE CONTRACT DOCUMENTS AND EXISTING CONDITIONS, NOTIFY THE ARCHITECT AT ONCE FOR INSTRUCTION ON HOW TO PROCEED.
4. SEWER, WATER, AND STORM DRAIN SYSTEMS INDICATED IN THESE DRAWINGS SHALL EXTEND TO PLUMBING/CIVIL POINTS OF CONNECTION AT 5'-0" OUTSIDE OF THE BUILDING(S) UNLESS NOTED OTHERWISE. CONTINUATION OF THESE
PIPING SYSTEMS ARE INDICATED ON THE CIVIL DRAWINGS WITH
CORRESPONDING ASSOCIATED MATERIALS SPECIFIED UNDER A SEPARATE SECTION OF THE PROJECT SPECIFICATIONS. ALL SUCH PIPING SHALL BE
INSTALLED IN A MANNER TO PROVIDE PROPER CONNECTION TO INVERT ELEVATIONS INDICATED ON CIVIL DRAWINGS. WHERE SIZES DIFFER BETWEEN
PLUMBING AND CIVIL DRAWINGS, CONTRACTOR SHALL PROVIDE TRANSITION FITTINGS AS NECESSARY TO ALLOW FOR PROPER CONNECTION.
5. TRAPS FOR ALL LAVATORIES AND SINKS SHALL TRAP STRAIGHT BACK TO WALL WITH ALL REQUIRED OFFSETS HAPPENING WITHIN THE WALL.
6. HORIZONTAL SOIL, WASTE AND TRAP PRIMER PIPING WITHIN THE BUILDING
SHALL BE INSTALLED CONCEALED WITHIN WALLS, BELOW FINISH FLOOR, OR BELOW FINISH SLAB AS APPLICABLE UNLESS NOTED OTHERWISE. ALL OTHER
HORIZONTAL PIPING WITHIN THE BUILDING SHALL BE INSTALLED CONCEALED
ABOVE CEILING OR WITHIN WALLS AS APPLICABLE UNLESS NOTED OTHERWISE. ALL VERTICAL PIPING SHALL BE INSTALLED CONCEALED WITHIN WALLS UNLESS NOTED OTHERWISE. NO PIPING SHALL BE INSTALLED IN EXPOSED LOCATIONS UNLESS SPECIFICALLY NOTED AS SUCH ON PLANS.
7. HORIZONTAL SOIL AND WASTE PIPING 4" AND GREATER IN SIZE SHALL SLOPE AT 1/8" PER FOOT UNLESS OTHERWISE NOTED. ALL SUCH PIPING 3" AND LESS IN SIZE SHALL SLOPE AT 1/4" PER FOOT UNLESS NOTED OTHERWISE.
8. HORIZONTAL STORM DRAIN AND OVERFLOW PIPING SHALL SLOPE AT 1/8" PER FOOT UNLESS NOTED OTHERWISE.
9. HORIZONTAL CONDENSATE PIPING SHALL SLOPE AT 1/8" PER FOOT UNLESS NOTED OTHERWISE.
10. PRIOR TO COMMENCING ANY WORK VERIFY ALL EQUIPMENT LOCATIONS WITH
THE GENERAL CONTRACTOR, OTHER TRADES, ARCHITECT AND STRUCTURAL ENGINEER. EXACT ROUGH-IN LOCATIONS AND REQUIREMENTS SHALL BE COORDINATED IN THE FIELD.
11. PIPING BETWEEN EACH PLUMBING FIXTURE AND THE NEAREST BRANCH OR
MAIN PIPING RUN SHALL BE SIZED TO MATCH THE CORRESPONDING FIXTURE
SCHEDULE CONNECTION SIZE AT A MINIMUM UNLESS NOTED AS A LARGER SIZE ON PLANS. PIPE HEADERS IN WALLS SERVING BANKS OF FIXTURES SHALL
BE FULL LINE SIZE FROM THE UPSTREAM END OF THE BRANCH LINE TO THE END TERMINAL UNLESS NOTED OTHERWISE.
12. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS, ROUGH IN
DIMENSIONS, AND MOUNTING HEIGHTS OF ALL FIXTURES, EQUIPMENT,
ACCESS PANELS, HOSE BIBBS, RECESSED HOSE BIBBS, OVERFLOW DRAIN TERMINATION POINTS, AND OTHER EXPOSED PLUMBING ELEMENTS. WHERE
DIMENSIONS ARE NOT INDICATED, SEEK ARCHITECT'S DIRECTION AND/OR APPROVAL PRIOR TO INSTALLATION.
13. ACCESS PANELS
A. WHERE POSSIBLE, USE SAME ACCESS PANEL FOR SHUT-OFF VALVES,
MIXING VALVES, TRAP PRIMERS AND WATER HAMMER ARRESTORS AND/OR
OTHER INTERIOR WALL COMPONENTS WHEN LOCATED DIRECTLY ADJACENT IN SAME IMMEDIATE VICINITY. SEE ARCHITECTURAL DRAWINGS FOR MOUNTING HEIGHTS.
B. SEE SPECIFICATIONS FOR ACCESS PANEL REQUIREMENTS.
14. CLEANOUTS.
A. INTERIOR CLEANOUTS SHALL BE WALL CLEANOUTS RATHER THAN FLOOR
CLEANOUTS UNLESS OTHERWISE INDICATED, SHALL BE READILY ACCESSIBLE,
AND SHALL BE CAREFULLY COORDINATED WITH CASEWORK, EQUIPMENT, AND OTHER ITEMS TO AVOID CONFLICT. NOT ALL REQUIRED CLEANOUTS ARE INDICATED ON PLANS. WALL CLEANOUTS IN FINISHED SPACES SHALL BE INSTALLED IN ACCESS PANELS.
B. SEE SPECIFICATIONS FOR ACCESS PANEL REQUIREMENTS.
15. YARD BOX AND CLEANOUT COVERS SHALL BE CLEARLY STAMPED WITH "WATER", "GAS", OR "SEWER" AS APPLICABLE. VALVES SHALL BE INSTALLED
AND PROPERLY POSITIONED WITHIN YARD BOX TO ALLOW FOR FULL RANGE OF OPERATION, MAINTENANCE, REPAIR, AND REPLACEMENT. ALL YARD BOXES
AND CLEANOUT COVERS SHALL ALIGN WITH SCORED HARDSCAPE JOINTS PER LANDSCAPE PLANS. YARD BOX COVERS SHALL BE CONCRETE. SEWER CLEANOUT COVERS SHALL BE BRASS. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.
16. VERIFY EXACT LOCATIONS OF ALL MECHANICAL AND/OR OTHER EQUIPMENT
INSTALLED BY OTHERS AND REQUIRING PLUMBING CONNECTIONS PRIOR TO ORDERING OF MATERIALS OR INSTALLATION. COORDINATE EXACT ROUGH-IN
LOCATIONS AND REQUIREMENTS WITH OTHER INSTALLING CONTRACTORS AS APPLICABLE PRIOR TO INSTALLATION.
17. ADA LAVATORIES AND SINKS SHALL BE PROVIDED WITH ADA INSULATED TRAP AND SUPPLY COVERS AS SPECIFIED.
18. ADA WATER CLOSETS SHALL BE INSTALLED WITH FLUSH VALVE ACTUATOR HANDLE LOCATED ON THE WHEEL CHAIR ACCESS SIDE.
19. ALL VALVES, UNIONS, CLEANOUTS, ETC. TO BE SAME SIZE AS PIPE UNLESS NOTED OTHERWISE.
20. REFER TO MECHANICAL DRAWINGS FOR MECHANICAL MANDATORY MEASURES AND ASSOCIATED REQUIREMENTS.
21. REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF ALL FIRE RATED ASSEMBLIES. PROVIDE FIRESTOPPING AT PENETRATIONS THROUGH FIRE RETARDANT CONSTRUCTION IN ACCORDANCE WITH SPECIFICATIONS. PIPING THROUGH FIRE RATED WALLS SHALL BE PER U.L. FIRE RESISTANCE SYSTEM NO. W-L-1001. SEE ARCHITECTURAL PLANS FOR WALL LOCATIONS.
22. NO PIPING SHALL BE INCASED IN THE CONCRETE SLAB.
23. ALL VALVES, TRAP PRIMERS, WATER HAMMER ARRESTERS OR OTHER
EQUIPMENT SHOWN IN WALLS OR ABOVE NON-ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL.
24. ALL PLUMBING FIXTURES AND EQUIPMENT SHALL BE CERTIFIED BY THE
CALIFORNIA STATE ENERGY COMMISSION TO COMPLY WITH EFFICIENCY STANDARDS PER SECTION 2-5314(A) OF THE TITLE-24 REGULATIONS.
25. ALL UNDERGROUND IRON, COPPER OR STEEL PIPING LOCATED BOTH INSIDE AND OUTSIDE OF BUILDING SHALL BE ENCASED WITHIN A MINIMUM 10 MIL
POLYETHYLENE PLASTIC SLEEVE SEALED WATER TIGHT WITH POLYVINYL CHLORIDE TAPE.
26. ALL POINTS OF CONNECTION SHALL BE COORDINATED WITH THE GENERAL CONTRACTOR PRIOR TO BID.
27. ALL HORIZONTAL PIPING LINES EXTENDED AND CONNECTED TO EQUIPMENT SHALL BE RUN AT THE HIGHEST POSSIBLE ELEVATIONS AND NOT LESS THAN 6" ABOVE THE FLOOR TO PROVIDE CLEARANCE FOR CLEANING. AT WALL OR
COLUMN LOCATIONS, PIPING ROUGH-IN SHALL BE STUBBED IN WALLS WHENEVER POSSIBLE.
28. ALL CUTTING OF EXISTING PAVINGS, WALKS AND/OR FLOORS SHALL BE BY MACHINE SAW CUTTING. HOLES FOR PIPES IN CONCRETE WALLS OR FLOORS SHALL BE DONE BY CORE DRILLING EQUIPMENT.
29. ABOVE GROUND PIPING SYSTEMS SHALL BE MARKED IN ACCORDANCE WITH ASME A13.1.
30. UNLESS SPECIFICALLY SHOWN ON THESE PLANS NO STRUCTURAL MEMBERS
SHALL BE CUT, DRILLED OR NOTCHED WITHOUT PRIOR WRITTEN
AUTHORIZATION FROM THE STRUCTURAL ENGINEER AND THE DISTRICT STRUCTURAL ENGINEER FROM THE DIVISION OF THE STATE ARCHITECT.
31. ALL CONCEALED CONDENSATE DRAIN PIPING ABOVE CEILING SHALL BE INSULATED WITH 3/4" CLOSED CELL FOAM. INSULATION SHALL BE EQUAL TO ARMACELL "ARMAFLEX".
32. VENT PIPING SHALL TERMINATE NOT LESS THAN 10 FEET FROM, OR NOT LESS THAN 3 FEET ABOVE, AN OPENABLE WINDOW, DOOR, OPENING, AIR INTAKE, OR VENT SHAFT.
2022 CALIFORNIA BUILDING STANDARDS ADMINISTRATIVE CODE, PART 1, TITLE 24 C.C.R.
2022 CALIFORNIA BUILDING CODE (CBC), PART 2, TITLE 24 C.C.R.; (2021 INTERNATIONAL BUILDING CODE OF THE INTERNATIONAL CODE
COUNCIL, WITH CALIFORNIA AMENDMENTS)
2022 CALIFORNIA ELECTRICAL CODE (CEC), PART 3, TITLE 24 C.C.R.; (2023 NATIONAL ELECTRICAL CODE OF THE NATIONAL FIRE PROTECTION
ASSOCIATION, NFPA)
2022 CALIFORNIA MECHANICAL CODE (CMC), PART 4, TITLE 24 C.C.R.; (2021 UNIFORM MECHANICAL CODE OF THE INTERNATIONAL ASSOCIATION OF
PLUMBING AND MECHANICAL OFFICIALS, IAPMO)
2022 CALIFORNIA PLUMBING CODE (CPC), PART 5, TITLE 24 C.C.R.; (2021 UNIFORM PLUMBING CODE OF THE INTERNATIONAL ASSOCIATION OF
PLUMBING AND MECHANICAL OFFICIALS, IAPMO)
2022 ENERGY CODE (CEC), PART 6, TITLE 24 C.C.R.;
2022 CALIFORNIA FIRE CODE, PART 9, TITLE 24 C.C.R.;
(2021 INTERNATIONAL FIRE CODE OF THE INTERNATIONAL CODE COUNCIL) 2022 CALIFORNIA GREEN BUILDING CODE (CAL GREEN), PART 11, TITLE 24 C.C.R. 2022 CALIFORNIA REFERENCED STANDARDS, PART 12, TITLE 24 C.C.R.
TITLE 19 C.C.R., PUBLIC SAFETY, STATE FIRE MARSHAL REGULATIONS.
PARTIAL LIST OF APPLICABLE STANDARDS
2022 CALIFORNIA BUILDING CODE (FOR SFM) REFERENCED STANDARDS CH. 35 NFPA 13 AUTOMATIC SPRINKLER SYSTEMS 2022 EDITION
(CALIFORNIA AMENDED)
NFPA 14 STANDPIPE SYSTEMS 2019 EDITION
(CALIFORNIA AMENDED)
NFPA 17 DRY CHEMICAL EXTINGUISHING SYSTEMS 2021 EDITION NFPA 17A WET CHEMICAL EXTINGUISHING SYSTEMS 2021 EDITION NFPA 20 STATIONARY PUMPS 2019 EDITION
NFPA 22 STANDARD FOR WATER TANKS FOR PRIVATE
FIRE PROTECTION 2016 EDITION
NFPA 24 PRIVATE FIRE SERVICE MAINS 2019 EDITION
(CALIFORNIA AMENDED)
NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE 2022 EDITION (CALIFORNIA AMENDED)
(NOTE: SEE UL STANDARD 1971 FOR "VISUAL
DEVICES")
NFPA 80 FIRE DOOR AND OTHER OPENING PROTECTIVES 2019 EDITION NFPA 253 CRITICAL RADIANT FLUX OF FLOOR COVERING 2019 EDITION
SYSTEMS
NFPA 2001 CLEAN AGENT FIRE EXTINGUISHING SYSTEMS 2018 EDITION (CALIFORNIA AMENDED)
BUILDING CODES: (APPLICABLE AS OF JANUARY 1, 2023)
ABBREVIATION DESCRIPTION
&AND
@ AT
ABV ABOVE
A/C AIR CONDITIONING
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
AFF ABOVE FINISH FLOOR
AHJ AUTHORITY HAVING JURISDICTION
AP ACCESS PANEL
APPROX APPROXIMATELY
ARCH ARCHITECT
ASD AUTOMATIC SPRINKLER DRAIN
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
AVTR ACID VENT THRU ROOF
BEL BELOW
BFF BELOW FINISHED FLOOR
BFG BELOW FINISHED GRADE
BFP BACKFLOW PREVENTER
BLDG BUILDING
BTUH BRITISH THERMAL UNIT PER HOUR
CA COMPRESSED AIR
CBC CALIFORNIA BUILDING CODE, CURRENT EDITION
CD CONDENSATE DRAIN
CEC CALIFORNIA ELECTRICAL CODE, CURRENT EDITION
CFC CALIFORNIA FIRE CODE, CURRENT EDITION
CFM CUBIC FEET PER MINUTE
CFH CUBIC FEET PER HOUR
CLG CEILING
CMC CALIFORNIA MECHANICAL CODE, CURRENT EDITION
CO CLEANOUT
COMB COMBUSTION
CONT CONTINUATION
CONTR CONTRACTOR
CPC CALIFORNIA PLUMBING CODE, CURRENT EDITION
CVTR CONCENTRIC VENT THRU ROOF
CWD CAN WASH DRAIN
(D)DEMOLISH
DET DETAIL
DEPT DEPARTMENT
DIA DIAMETER
DN DOWN
DWG DRAWING
Ø DIAMETER
E EAST
EA EACH
EXIST EXISTING
(E)EXISTING
ELEC ELECTRICAL
ENGR ENGINEER
EOR ENGINEER ON RECORD
ET EXPANSION TANK
EXH EXHAUST
F FAHRENHEIT
FD FLOOR DRAIN
FFE FINISH FLOOR ELEVATION
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FLR FLOOR
FM FACTORY MANUAL
FPS FEET PER SECOND
FT FOOT, FEET
FV FLUSH VALVE
GA GAUGE
GAL GALLONS
GPM GALLONS PER MINUTE
GVTR GREASE VENT THRU ROOF
HDR HEADER
HORIZ HORIZONTAL
HBD HOSE BIBB DRAINAGE
HP HORSE POWER
HVAC HEATING VENTILATION AND AIR CONDITIONING
HZ HERTZ
ICW INDUSTRIAL COLD WATER
IE INVERT ELEVATION
IN INCHES
IN WC INCHES WATER COLUMN
INT INTEGRAL
IRR IRRIGATION
KW KILOWATT
LBS POUNDS
MAX MAXIMUM
MBH THOUSAND BRITISH THERMAL UNITS PER HOUR
MC MECHANICAL CONTRACTOR
MECH MECHANICAL
MFR MANUFACTURER
MIN MINIMUM
N NORTH
NA NOT APPLICABLE
NIC NOT IN CONTRACT
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NO NUMBER
NTS NOT TO SCALE
OC ON CENTER
OCD OVERFLOW CONDENSATE DRAIN
OD OVERFLOW DRAIN, OUTSIDE DIAMETER
P PUMP
PCD PUMPED CONDENSATE DRAIN
PH PHASE
PLBG PLUMBING
POC POINT OF CONNECTION
POD POINT OF DISCONNECTION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
RO REVERSE OSMOSIS
RPM REVOLUTIONS PER MINUTE
RW RECLAIMED WATER
S SOUTH
SD STORM DRAIN
SF SQUARE FOOT
SHD SHOWER DRAIN
SIM SIMILAR
SPKLR SPRINKLER
SCW SOFT COLD WATER
SS SANITARY SEWER
SST STAINLESS STEEL
STD STANDARD
STRUCT STRUCTURAL
SYS SYSTEM
TD TRENCH DRAIN
TEMP TEMPERATURE
THRU THROUGH
T'STAT THERMOSTAT
TYP TYPICAL
UL UNDERWRITER'S LABORATORY
UNO UNLESS NOTED OTHERWISE
VA VACUUM
V VOLT
VBF VENT BELOW FLOOR
VBG VENT BELOW GRADE
VTR SANITARY VENT THRU ROOF
W WEST
W/WITH
W/O WITHOUT
WCO WALL CLEANOUT
WC WATER COLUMN
WT WEIGHT
YB YARD BOX
CS
RPBP
FS
PS
DESCRIPTIONABBREVIATIONSYMBOL
ACID VENT PIPINGAV
WALL CLEANOUT
HOSE BIBB
/
PRESSURE REDUCING VALVE
CHECK VALVE
SOV / SOC
IN WALL AP
WCO
PRV
CV
REDUCED PRESSURE BACKFLOW PREVENTERRPBP
FLOOR CLEANOUTFCO
CLEANOUT TO GRADECOTG
FLOOR DRAIN OR AREA DRAIN
HB
UNION
SLEEVE
STRAINER
PUMP
PRESSURE GAUGE
TEMPERATURE GAUGE
TEMPERATURE AND PRESSURE RELIEF VALVETPV
CAP ON END OF PIPE
PIPE RISER DOWN (ELBOW)
PIPE RISER UP (ELBOW)
PIPE RISE OR DROP
BRANCH LINE TOP CONNECTION
BRANCH LINE BOTTOM CONNECTION
FLOW IN DIRECTION OF ARROW
WATER HAMMER ARRESTOR IN WALL ACCESS PANEL
FLOW SWITCH
PRESSURE SWITCH
AQUASTAT
SEISMIC JOINT
TRAP PRIMER WITH SOV IN WALL ACCESS PANELTP W/ SOV
WHA IN WALL AP
BALANCING VALVEBLV
SHUT-OFF VALVE / SHUT-OFF COCK IN WALL ACCESS PANEL
SOV SHUT-OFF VALVE ABOVE FINISHED GRADE
CONTINUATION OF PIPING
RECESSED HOSE BIBBRHB
FLOOR SINK
CONTROL STATION
DRYWELL
OVERFLOW DRAIN SPILL TO GRADE
ROOF RECEPTOR
P1
T1
FLOOR DRAIN OR AREA DRAIN
HATCH INDICATES ITEM(S) TO BE DEMOLISHED
SOC SHUT-OFF COCK ABOVE FINISHED GRADE
ACCESS PANELAP
WASHING MACHINE OUTLET BOX WITH 1/4 TURN VALVESWB
ICE MAKER OUTLET BOX WITH 1/4 TURN VALVEIB
SOLENOID VALVESV
GAS TURRET
SOV IN
CLG AP SHUT-OFF VALVE IN CEILING ACCESS PANEL
SOV
IN YB SHUT-OFF VALVE BELOW FINISHED GRADE IN YARD BOX
SOC
IN YB SHUT-OFF COCK BELOW FINISHED GRADE IN YARD BOX
SOC IN
CLG AP SHUT-OFF COCK IN CEILING ACCESS PANEL
GAS PRESSURE REGULATORGPR
MV /
TMV MIXING VALVE / THERMOSTATIC MIXING VALVE
ACID WASTE PIPING ABOVE FINISHED FLOORAW
ACID WASTE PIPING UNDERGROUNDAW-U
GREASE VENT PIPINGGV
GREASE WASTE PIPING ABOVE FINISHED FLOORGW
GREASE WASTE PIPING UNDERGROUNDGW-U
SANITARY VENT PIPINGV
SANITARY SOIL OR WASTE PIPING ABOVE FINISHED FLOORSS
SANITARY SOIL OR WASTE PIPING UNDERGROUNDSS-U
OVERFLOW DRAIN PIPINGOD
STORM DRAIN PIPING ABOVE FINISHED FLOORSD
STORM DRAIN PIPING UNDERGROUNDSD-U
CONDENSATE DRAIN PIPINGCD
OVERFLOW CONDENSATE DRAIN PIPINGOCD
HOSE BIBB DRAINAGE PIPINGHBD
RECLAIMED WATER PIPINGRW
IRRIGATION PIPINGIRR
INDUSTRIAL COLD WATER PIPINGICW
REVERSE OSMOSIS BLENDED WATER PIPINGRO
DOMESTIC COLD WATER PIPINGCW
DOMESTIC HOT WATER PIPINGHW
DOMESTIC HOT WATER RETURN PIPINGHWR
DOMESTIC TEMPERED WATER PIPINGTW
DOMESTIC TEMPERED WATER RETURN PIPINGTWR
DOMESTIC SOFT COLD WATER PIPINGSCW
DOMESTIC SOFT HOT WATER RETURN PIPINGSHWR
SUBSOIL DRAINAGE PIPINGSSD
VACUUM PIPINGVAC
COMPRESSED AIR PIPINGCA
STANDARD PRESSURE GAS PIPING (8" W.C.)G
MEDIUM PRESSURE GAS PIPING (5 PSI)MPG
MEDIUM PRESSURE GAS PIPING UNDERGROUND (5 PSI)MPG-U
WATER HEATER COMBUSTION AIRCOMB. AIR
WATER HEATER EXHAUST AIREXH. AIR
WATER HEATER CONCENTRIC VENT THRU ROOFCVTR
FD
FD
FS
GT
RR
REVISION
DETAIL
DEMOLITION KEYNOTE
PLAN IDENTIFICATION
SHEET WHERE PLAN IS DRAWN
CONTINUATION
PLAN IDENTIFICATION
SHEET WHERE PLAN IS DRAWN
ENLARGED PLAN
CLOUD AROUND REVISED AREA OPTIONAL
KEYNOTE IDENTIFICATION
OCCURANCE
SPECIFIC INFORMATION
DEMOLITION KEYNOTE IDENTIFICATION
OCCURANCE
DETAIL IDENTIFICATION
SHEET WHERE DETAIL IS DRAWN
OCCURANCE
FIXTURE IDENTIFICATION
OCCURANCE
SPECIFIC INFORMATION
FIXTURE OR EQUIPMENT IDENTIFICATION
1 FOOD SERVICE SCHEDULE REFERENCE NO.
OCCURANCE
SPECIFIC INFORMATION
SEE 1
P8.01 TYP
1 P4.01
SEE 1
P2.01 FOR CONT
RD-1 3", 900 SF
TYP OF 4
109 IW TO FS-1
TYP OF 2
0101 1", 150 CFH
TYP OF 3
0101
TYP OF 4
1. ALL EQUIPMENT, PIPING, UTILITIES, AND THEIR CONNECTIONS SHALL BE
SEISMICALLY BRACED PER LATEST CBC AND EQUIPMENT ANCHORAGE FOR
PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTES PER STRUCTURAL DRAWINGS.
2. LIMITS TO NON-STRUCTURAL ITEMS SUSPENDED FROM CONCRETE FILLED METAL DECKING: HANGERS SUPPORTED BY METAL DECKING WITH
STRUCTURAL CONCRETE FILL MAY BE INSTALLED USING ICC-ES APPROVED ANCHORAGE SYSTEMS. DO NOT SUPPORT UTILITIES FROM METAL DECK WITHOUT CONCRETE. HANGERS FROM CONCRETE FILLED DECK, WHERE OCCURS, ARE LIMITED TO 4-INCH DIAMETER PIPE MAXIMUM. LOCATE HANGERS TWO FLUTES APART ON SAME DECK SPAN. SUPPORT LARGER PIPING FROM STRUCTURAL BEAMS OR COLUMNS. ADD DOUBLE UNISTRUT SPREADERS AS NECESSARY.
3. PROVIDE SHOP DRAWINGS WITH LARGE SCALE PLANS AND SECTIONS SHOWING HANGERS AND BRACING LOCATIONS. SHOP DRAWINGS SHALL BE
PREPARED BY A STRUCTURAL ENGINEER LICENSED IN THE STATE OF CALIFORNIA AND SHALL BE STAMPED AND SIGNED. INDICATE HANGERS AND BRACING LOADS ON STRUCTURAL FRAMING PLANS.
4. EXPANSION ANCHORS AND EPOXY ANCHORS, WHERE USED, SHALL HAVE A
MINIMUM EMBEDMENT OF EIGHT TIMES THE ANCHOR DIAMETER AND A MINIMUM EDGE DISTANCE OF 10 TIMES THE DIAMETER. EXPANSION ANCHORS AND EPOXY ANCHORS MUST HAVE CURRENT AND VALID ICC REPORT. SHOT PINS ARE NOT ACCEPTABLE.
5. UNLESS SPECIFIED ON STRUCTURAL DRAWINGS, ANY ALTERATIONS OR
MODIFICATIONS TO A STRUCTURAL ELEMENT BY CUTTING, DRILLING, BORING, BRACING, WELDING, ETC. SHALL HAVE WRITTEN APPROVAL BY THE STRUCTURAL ENGINEER OF RECORD AND DSA PRIOR TO STARTING WORK.
6. SEE GENERAL NOTES ON STRUCTURAL DRAWINGS FOR ADDITIONAL REQUIREMENTS.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 As indicatedCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
PLUMBING
LEGENDS AND
GENERAL NOTES
P0.10
01/06/2023
CheckerSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGGENERAL NOTES
APPLICABLE CODES
ABBREVIATIONSPLUMBING LEGENDPLUMB ANNOTATION SYMBOLS1 GENERAL STRUCTURAL NOTES
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
PLUMBING FIXTURE
SCHEDULES
P0.20
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGPLUMBING FIXTURE SCHEDULE ITEM MANUFACTURER MODEL NO. FIXTURE TYPE
ROUGH-IN CONNECTION SIZES (in)
MOUNT HARDWARE TYPE DESCRIPTIONWASTE VENT COLD
WATER
HOT
WATER
DF-1 ELKAY LZWS-LRPBM28K
FILTERED,
REFRIGERATED
DRINKING FOUNTAIN
W/ BOTTLE FILLER
2" 1 1/2" 3/4"WALL MOUNT ELECTRIC DRINKING FOUNTAIN WITH BOTTLE FILLER, WALL MOUNT, FILTERED, ADA COMPLIANT, DUAL-HEIGHT, CALIF AB-1953 COMPLIANT, STAINLESS STEEL CONSTRUCTION WITH FRONT ACCESS PANEL. FLEXI-GUARD SAFETY BUBBLER WITH PUSH ACTIVATION.
RECESSED CHILLER/COMPRESSOR RATED AT 115 VOLTS, 60 HZ., 1 PHASE, 1.0 AMPS, 370 WATTS TO DELIVER 8 GPH FILL RATE AT 50°F. COMPLETE WITH CHICAGO MODEL No. 45LK STRAIGHT STOPS. INSTALL IN ACCORDANCE WITH ADA ACCESSIBILITY REQUIREMENTS.
DSB-1 Zurn Industries, LLC Z191-RD-18-CA DOWNSPOUT BOOT 4 X 18 Downspout Boot ET-1 ZURN XT-8 THERMAL EXPANSION
TANK WALL MOUNT ZURN WILKINS, CARBON STEEL OUTER SHELL, NPT STAINLESS STEEL SYSTEM CONNECTION, 2.1 GALLONS.
FCO-1 ZURN Z1400-BZ FLOOR CLEANOUT FLOOR MOUNT "LEVEL-TROL" ADJUSTABLE LEVELING FLOOR CLEANOUT, DURA-COATED CAST IRON BODY WITH GAS & WATER TIGHT ABS TAPERED THREAD PLUG, AND ROUND, SCORIATED SECURED LIGHT-DUTY TOP WITH ADDITIONAL LEVELING ADJUSTMENT TO FINISHED FLOOR.
FD-1 J.R. SMITH 2005Y-02-P050-U FLOOR DRAIN,
SQUARE STRAINER 2" 1 1/2"FLOOR MOUNT FLOOR DRAIN WITH 2" OUTLET, DUCO CAST IRON DRAIN BODY WITH FLASHING COLLAR AND 5" SQUARE NICKEL-BRONZE ADJUSTABLE STRAINER WITH 1/2" TRAP SEAL PRIMER CONNECTION.
FD-2 J.R. SMITH 2005Y-02-P050-U FLOOR DRAIN, ROUND
STRAINER 2" 1 1/2"FLOOR MOUNT FLOOR DRAIN WITH 2" OUTLET, DUCO CAST IRON DRAIN BODY WITH FLASHING COLLAR AND 5" DIAMETER ROUND NICKEL-BRONZE ADJUSTABLE STRAINER WITH 1/2" TRAP SEAL PRIMER CONNECTION.
FS-1 J.R. SMITH 3430Y-C-12 FLOOR SINK 2" 2"FLOOR MOUNT SANI-FLOOR RECEPTOR 12"x12"x6" DEEP CAST IRON BODY AND SQUARE, LIGHT-DUTY GRATE WITH 1/2" SLOTTED OPENINGS, WHITE ACID RESISTANT PORCELAIN ENAMEL COATED INTERIOR & TOP, COMPLETE WITH WHITE ABS ANIT-SPLASH INTERIOR BOTTOM DOME STRAINER.
IMB-1 GUY GRAY MIB1AB ICEMAKER SUPLY
BOX, FIRE RATED WALL MOUNT "WHITE POWER COATED METAL IMOB 1/4 TURN VALVE - 1/2" SWEAT CONX", CALIF. AB 1953 COMPLIANT, RECESSED WALL TYPE, 1/4 TURN VALVE & MOUNTED IN HEAVY DUYT STEEL ENCLOSURE W/ WHITE POWDER COAT FINISH & TWO FACTORY INSTALLED INTUMESCENT PADS, ONE OR TWO HOUR RATED DEPENDING ON WALL CONSTRUCTION. INSTALL IN ACCORDANCE WITH MFR'S RECOMMENDATIONS.
L-1 KOHLER KINGSTON No. K-2005 LAVATORY, ADA 2" 1 1/2" 3/4" 3/4" WALL MOUNT SLOAN "OPTIMA" ETF-880 LAVATORY, ADA COMPLIANT, WHITE VITREOUS CHINA, WALL MOUNTED, CONCEALED HANGER, 4" CENTERS, W/ OVERFLOW, COMPLETE W/ CHROME FINISH DECK MOUNTED FAUCET WITH COVER PLATE & VANDAL RESISTANT OUTLET, CALIF AB 1953 COMPLIANT (0.5 GPM), McGUIRE MODEL No. 155A 1-1/4" CAST BRASS CHROME PLATED OPEN GRID P.O. PLUG, McGUIRE "PROWRAP VANDAL TRAP" MODEL No. PWV8090NC0 1-1/4" L.A. PATTERN P-TRAP WITH PRE-WRAPPED TRAP AND SUPPLY COVERS, GALVANIZED NIPPLE TRAP ARM W/ CHROMIUM PLATED BRASS CASING, CHICAGO "ECAST" MODEL No. 1017-ABCP LOOSE KEY STOPS WITH RIGID SUPPLIES, CALIF AB 1953 COMPLIANT, & MIFAB MODEL No. MC-41 FIXTURE CARRIER W/ CONCEALED ARMS. INSTALL IN ACCORDANCE WITH ADA ACCESSIBILITY REQUIREMENTS.
L-2 TOTO USA, Inc.LT191 LAVATORY,
UNDERMOUNT ADA 2" 1 1/2" 3/4" 3/4" UNDER MOUNT
LAVATORY, ADA COMPLIANT, WHITE VITREOUS CHINA, W/ OVERFLOW, COMPLETE W/ CHROME FINISH DECK MOUNTED FAUCET WITH COVER PLATE & VANDAL RESISTANT OUTLET, CALIF AB 1953 COMPLIANT (0.35 GPM), McGUIRE MODEL No. 155A 1-1/4" CAST BRASS CHROME PLATED OPEN GRID P.O. PLUG, McGUIRE "PROWRAP VANDAL TRAP" MODEL No. PWV8090NC0 1-1/4" L.A. PATTERN P-TRAP WITH PRE-WRAPPED TRAP AND SUPPLY COVERS, GALVANIZED NIPPLE TRAP ARM W/ CHROMIUM PLATED BRASS CASING, CHICAGO "ECAST" MODEL No. 1017-ABCP LOOSE KEY STOPS WITH RIGID SUPPLIES, CALIF AB 1953 COMPLIANT. INSTALL IN ACCORDANCE WITH ADA ACCESSIBILITY REQUIREMENTS.
S-1 ELKAY LUSTERTONE MODEL
No. ELUHAD311855
DOUBLE COMP SINK,
ADA 2" 1 1/2" 3/4" 3/4" UNDER MOUNT DELTA DSP-K-100LF-HDF ADA SINGLE COMPARTMENT, 18 GAUGE TYPE 304 STAINLESS STEEL, UNDERMOUNT SINK, 21.5" X 18.5" X 5-1/2" DEEP, COMPLETE W/ DECK MOUNTED FAUCET, CALIF AB 1953 COMPLIANT, (1.5 GPM),INSINKERATOR "BADGER 1" GARBAGE DISPOSAL, McGUIRE MODEL No. 151 BRASS BASKET STRAINER, McGUIRE MODEL No. PW8089NC0 1-1/2" L.A. PATTERN P-TRAP WITH PRE-WRAPPED TRAP AND SUPPLY COVERS, GALVANIZED NIPPLE TRAP ARM W/ CHROMIUM PLATED BRASS CASING, & CHICAGO "ECAST" MODEL No. 1017-ABCP LOOSE KEY STOPS WITH RIGID SUPPLIES, CALIF AB 1953 COMPLIANT. INSTALL IN ACCORDANCE WITH ADA ACCESSIBILITY REQUIREMENTS.
S-2 ELKAY LUSTERTONE MODEL
No. ELUHAD191655
SINGLE COMP SINK,
ADA 2" 1 1/2" 3/4" 3/4" UNDER MOUNT DELTA DSP-K-100LF-HDF S-3 ELKAY LUSTERTONE MODEL
No. ELUHAD191655
SINGLE COMP SINK,
ADA 2" 1 1/2" 3/4" 3/4" UNDER MOUNT DELTA DSP-K-100LF-HDF SI-1 ZURN Z1180 SOLIDS
INTERCEPTOR 2" 1 1/2"UNDERCOUNTER ZURN ACID RESISTANT SOLIDS INTERCEPTOR WITH REMOVABLE PVC SEDIMENT BUCKET AND TOP ACCESS GASKETED SECURED COVER.
SS-1 AMERICAN STANDARD 7745.811 SERVICE SINK -
CORNER 3" 2" 3/4" 3/4" FLOOR MOUNT T&S BRASS B-0665-BSTR ENAMELED CAST IRON, CORNER MOP SINK, 28"X28"X8" DEEP, HW & CW, WALL MOUNTED FAUCET WITH SUPPORT ROD, VACUUM BREAKER, LEVER HANDLES, BUILT-IN SHUT-OFF STOPS AND PAIL HOOK, 3/4" MALE HOSE THREAD OUTLET, VINYL RIM GUARD & HOSE AND 3" DIAMETER DRAIN WITH FLAT CHROME STRAINER.
TMV-1 LEONARD VALVE 270-LF-BRKT
POINT OF USE
THERMOSTATIC
MIXING VAVLE
3/4" 3/4" WALL MOUNT POINT OF USE THERMOSTATIC MIXING VALVE WITH INTEGRAL CHECK VALVES ON HOT AND COLD INLETS, 1/2" INLETS & 1/2" OUTLET, 0.25 GPM MIN FLOW CAPACITY, 12 GPM MAX FLOW CAPACITY. INSTALL WITH SHUT OFF VALVES AND WALL MOUNTING BRACKET. SET OUTPUT TEMPERATURE TO 105 DEGREES.
TP-1 MIFAB MR-500 TRAP PRIMER,
MULTIPLE DRAIN 1/2"WALL MOUNT MIFAB MODEL NO. MR-500 PRESSURE DROP ACTIVATED TRAP SEAL PRIMER, 1/2" MALE NPT INLET AND 1/2" FEMALE NPT OUTLET & REMOVABLE FILTER SCREEN. INSTALL COMPLETE WITH WALL ACCESS PANEL, SHUT-OFF VALVE, MIFAB NO. MI-DU TRAP SEAL PRIMER DISTRIBUTION UNIT, & 1/2" TYPE "L" COPPER DRAIN LINES FROM TRAP SEAL PRIMER DISTRIBUTION UNIT OUTLETS TO EACH RECEPTOR CONNECTION POINT.
UR-1 KOHLER BARDON No.
K-4991-ETSS URINAL 2" 1 1/2" 3/4"WALL MOUNT SLOAN ROYAL 186 ESS-0.125-DBP-TMO-HW WALL MOUNTED URINAL, WASHOUT ACTION, WHITE VITREOUS CHINA COMPLETE W/ HARDWIRD, SENSOR-OPERATED, FLUSH VALVE WITH TRUE MECHANICAL OVERRIDE (0.125 GPF), & MIFAB MODEL No. MC-32 CARRIER.
UR-2 KOHLER BARDON No.
K-4991-ETSS URINAL, ADA 2" 1 1/2" 3/4"WALL MOUNT SLOAN ROYAL 186 ESS-0.125-DBP-TMO-HW
WALL MOUNTED URINAL, WASHOUT ACTION, WHITE VITREOUS CHINA COMPLETE W/ HARDWIRD, SENSOR-OPERATED, FLUSH VALVE WITH TRUE MECHANICAL OVERRIDE (0.125 GPF), & MIFAB MODEL No. MC-32 CARRIER. INSTALL IN ACCORDANCE WITH ADA ACCESSIBILITY REQUIREMENTS.
WC-1 KOHLER KINGSTON No. K-4325 WATER CLOSET 4" 2" 1"WALL MOUNT SLOAN ROYAL 111 ESS-1.28-TMO WATER CLOSET, SIPHON JET ACTION, ELONGATED BOWL, WHITE VITREOUS CHINA, COMPLETE W/ HARDWIRED, SENSOR-OPERATED, FLUSH VALVE WITH TRUE MECHANICAL OVERRIDE (1.28 GPF), & OLSONITE MODEL No. 95SSCT "STA-TITE" (AS MANUFACTURED BY BEMIS) WHITE ELONGATED OPEN FRONT SEAT LESS COVER W/ STAINLESS STEEL CHECK HINGE & MIFAB No. MC-10 OR MC-13 SERIES CARRIER.
WC-2 KOHLER KINGSTON No. K-4325 WATER CLOSET, ADA 4" 2" 1"WALL MOUNT SLOAN ROYAL 111 ESS-1.28-TMO WATER CLOSET, ADA COMPLIANT, SIPHON JET ACTION, ELONGATED BOWL, WHITE VITREOUS CHINA, COMPLETE W/ HARDWIRED, SENSOR-OPERATED, FLUSH VALVE WITH TRUE MECHANICAL OVERRIDE (1.28 GPF), OLSONITE MODEL No. 95SSCT "STA-TITE" (AS MANUFACTURED BY BEMIS) WHITE ELONGATED OPEN FRONT SEAT LESS COVER W/ STAINLESS STEEL CHECK HINGE & MIFAB No. MC-10 OR MC-13 SERIES CARRIER. INSTALL IN ACCORDANCE WITH ADA ACCESSIBILITY REQUIREMENTS.
WCO ZURN Z1441 WALL CLEANOUT WALL MOUNT WALL CLEANOUT, DURA-COATED CAST IRON BODY WITH GAS & WATER TIGHT ABS TAPERED THREAD PLUG, AND ROUND, SMOOTH STAINLESS STEEL ACCESS COVER WITH SECURING SCREW.
WHA-1 PPP SC SERIES WATER HAMMER
ARRESTOR WALL MOUNT PISTON OPERATED WATER HAMMER ARRESTOR, CALIF. AB 1953 COMPLIANT, HARD DRAWN SEAMLESS TYPE "K" COPPER BODY, MPT BRASS CONNECTION. INSTALL COMPLETE W/ WALL ACCESS PANEL. WATER HAMMER ARRESTORS SHALL BE SIZED IN ACCORDANCE W/ MFR'S SIZING CRITERIA PER FIXTURE UNIT CAPACITY SERVED AT EACH LOCATION/OCCURRANCE.
WS-1 INSINKERATOR FC3010 COLD WATER SPIGOT 3/4"STAINLESS STEEL COLD WATER FAUCET. CONNECT PENTAIR "EVERPURE SERIES DRINKING WATER FILTRATION.
ELECTRIC WATER HEATER SCHEDULE
ITEM MANUFACTURER MODEL NO.LOCATION STORAGE CAPACITY
(GAL.)
INCOMING CW TEMP
(DEG. F.)
OUTGOING HW TEMP
(DEG. F.)
TEMP RISE
(DEG. F.)
RECOVERY
(GAL/HR)
OPERATING
WEIGHT (LBS)
ELECTRICAL DESCRIPTIONVOLTAGE AMPS PHASE kW
EWH-1 AO SMITH DEN-40 JANITOR'S ROOM 109 50 50 140 90 23 458 480 V 10.4 A 3 5 COMMERCIAL ELECTRIC TANK TYPE WATER HEATER WITH DRAIN PAN.
MOUNT ON CONCRETE PAD, DRAIN TO FLOOR SINK.
EWH-2 EEMAX SPEX8208T STEM 111 & 112 N/A 50 110 MAX 57 NA 4 208 V 40.0 A 1 8.3 ACCUMIX ELECTRIC TANKLESS WATER HEATER
ELECTRIC TRAP PRIMER SCHEDULE
ITEM MANUFACTURER MODEL NO.LOCATION INLET SIZE ELECTRICAL EQUIPMENT SIZE DESCRIPTIONVOLTAGE AMPS PHASE kW ETP-1 PRECISION PLUMBING
PRODUCTS MPB-500-115V FIRE RISER 115 1/2"115 V 1 12"x12"x4"MINI-PRIME ELECTRONIC FLOOR DRAIN TRAP PRIMER W/NEMA1 BOX, 115V
ETP-1 PRECISION PLUMBING
PRODUCTS MPB-500-115V MECHANICAL ROOM
103 1/2"115 V 1 12"x12"x4"MINI-PRIME ELECTRONIC FLOOR DRAIN TRAP PRIMER W/NEMA1 BOX, 115V
CIRCULATING PUMP SCHEDULE
ITEM MANUFACTURER MODEL NO.LOCATION TYPE CAPACITY ELECTRICAL OPERATING WEIGHT (LBS)DESCRIPTIONGPM HEAD VOLTAGE AMPS PHASE kW HP RPM CP-1 GRUNDFOS UP 15-42 B7 JANITOR'S ROOM 109 CIRCULATION PUMP 17.2 15.1 115 V 1 A .085 6.7 STAINLESS STEEL PUMP.
NOTES:
1. ALL BRAZED AND SOLDERED JOINTS SHALL BE LEAD FREE. EXPOSED VENT PIPE SHALL BE GALVANIZED PER SPECIFICATIONS.
2. ALL METALLIC PIPING BELOW GRADE SHALL BE ENCASED WITH 10 MIL MINIMUM POLYETHYLENE PLASTIC SLEEVE. ALL FITTINGS, VALVES, ETC. THAT ARE NOT ABLE TO BE ENCASED WITHIN SLEEVE SHALL PROVIDE HEAVY OF "HENRY'S" OIL BASE ROOF MASTIC OVER ENTIRE SURFACE AND WRAPPED ENTIRE COMPONENT BY 10 MIL FERGUSON POLYETHYLENE WRAP WITH OVERLAPPED 50% OF THE CIRCUMFERENCE. SECURE ENDS AND SEAMS BY 3M SCOTCH, 10 MIL, 2" WIDE PIPE WRAP SEALING TAPE. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.
BELOW GRADE OUTSIDE WITHIN FIVE FEET (5') OF THE FOUNDATION SHALL BE PVC PIPE APPROVED FOR FIRE SERVICE CLASS 150 (DR-18) WITH CAST IRON, RING-TITE FITTINGS AS REQUIRED.
FIRE PROTECTION
ABOVE GRADE DUCTILE IRON, CEMENT LINED WITH MECHANICAL JOINT FITTINGS, CLASS 250, FLANGED OR MECHANICAL JOINT, IN ACCORDANCE WITH ANSI-AWWA C111/A21.11, CLASS 52 OR AWWA C153 DUCTILE IRON COMPACT FITTINGS.
BELOW FLOOR SAME AS ABOVE ENCASED WITHIN A MINIMUM OF 10 MIL POLYETHYLENE PLASTIC SLEEVE SEALED WATER TIGHT WITH POLYVINYL CHLORIDE TAPE.
SANITARY VENT
ABOVE FLOOR HUBLESS CAST IRON PIPE AND FITTINGS, ASTM A 888 OR CISPI 301, SHIELDED COUPLINGS ASTM C 1277, STANDARD-DUTY, 2-BAND SHIELDED, STAINLESS-STEEL COUPLINGS AND ASTM C 564 RUBBER SLEEVE.
BELOW FLOOR SAME AS ABOVE ENCASED WITHIN A MINIMUM OF 10 MIL POLYETHYLENE PLASTIC SLEEVE SEALED WATER TIGHT WITH POLYVINYL CHLORIDE TAPE.
SANITARY WASTE
ABOVE FLOOR HUBLESS CAST IRON PIPE AND FITTINGS, ASTM A 888 OR CISPI 301, SHIELDED COUPLINGS ASTM C 1540, HEAVY-DUTY, 4-BAND SHIELDED, STAINLESS-STEEL COUPLINGS AND ASTM C 564 RUBBER SLEEVE.
BELOW FOOR SAME AS ABOVE ENCASED WITHIN A MINIMUM OF 10 MIL POLYETHYLENE PLASTIC SLEEVE SEALED WATER TIGHT WITH POLYVINYL CHLORIDE TAPE.
STORM / OVERFLOW
DRAIN
ABOVE FLOOR HUBLESS CAST IRON PIPE AND FITTINGS, ASTM A 888 OR CISPI 301, SHIELDED COUPLINGS ASTM C 1540, HEAVY-DUTY, 4-BAND SHIELDED, STAINLESS-STEEL COUPLINGS AND ASTM C 564 RUBBER SLEEVE.
WITHIN BUILDING SAME AS ABOVE EXCEPT WITH 1-INCH THICK FLEXIBLE ELASTOMERIC, COMPLYING WITH ASTM C534/C534M GRADE 1; USE TUBULAR MATERIAL WHEREVER POSSIBLE.
CONDENSATE DRAIN
ON ROOF HARD DRAWN COPPER DWV TUBE, ASTM B 306, DRAINAGE TUBE, DRAWN TEMPER. COPPER DRAINAGE DWV FITTINGS, ASME B16.23, CAST COPPER OR ASME B16.29, WROUGHT COPPER, SOLDER-JOINT FITTINGS.
HOT WATER
SAME AS COLD WATER ABOVE COMPLETE WITH 1" THICK ONE-PIECE PRE-FORMED GLASS FIBER MOLDED PIPE INSULATION WITH ALL PURPOSE FIRE RETARDANT VAPOR BARRIER JACKET FOR 3/4" DIAMETER PIPES AND SMALLER, 1-1/2" THICK INSULATION FOR 1" TO 1-1/2" DIAMETER PIPES AND 2" THICK INSULATION FOR 2" DIAMETER PIPES AND LARGER. (VIEGA PRO PRESS FITTINGS ARE AN ACCEPTABLE SUBSTITUTION FOR SOLDER JOINTS).
BELOW FLOOR
SOFT COPPER TUBE, ASTM B88, TYPE K WATER TUBE, ANNEALED TEMPER. COPPER SOLDER-JOINT FITTINGS, ASME B16.22, WROUGHT-COPPER PRESSURE FITTINGS. ENCASE WITHIN A HIGH DENSITY CROSS LAMINATED POLYETHYLENE FILM, MINIMUM 10 MIL THICK, TUBE FORM, ASTM 1674 OR AWWA C105, FOR PROTECTION AGAINST CORROSION.DOMESTIC WATER COLD WATER HARD COPPER TUBE, ASTM B88, TYPE L WATER TUBE, DRAWN TEMPER. WROUGHT-COPPER SOLDER-JOINT FITTINGS (VIEGA PRESS FITTINGS ARE AN ACCEPTABLE SUBSTITUTION FOR SOLDER JOINTS), ASME B16.22, WROUGHT-COPPER PRESSURE FITTINGS.
SERVICES LOCATION MATERIAL
PIPE MATERIALS SCHEDULE
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
PLUMBING
CALCULATION
P0.30
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING4 185 840 -4.7 3 105 406 -4.8
PRESSURE SELECTED FOR UNIFORM LOSS 5 PSI/100FT 2 1/2 74 245 -4.8 PRSSURE AVAILABLE FOR UNIFORM LOSS 13.3 PSI/100FT 2 48 119 -4.9 GPM Calculations based on Flush Valves DEVELOPED LENGTH OF HORIZONTAL WATER PIPING WITHIN THE BUILDING 150 FT 1 1/2 27 46 -4.9 CONVERT TO GPM =60 -PRESSURE AVAILABLE FOR PIPE SIZING 20 PSI 1 1/4 19 28 -5 TOTAL FIXTURE UNITS = 79.5 57.0 PRESSURE LOSS THROUGH ADDITIONAL EQUIPMENT (PRV, MV, BFP OR OTHER)-4 PSI 1 12 16 -4.9 EMPTY 0 X 0.0 0.0 0.0 0.0 PRESSURE LOSS DUE TO ELEVATION, BUILDING INLET TO CONTROLLING FIXTURE -7 PSI 3/4 6 7 -4.4 EMPTY 0 X 0.0 0.0 0.0 0.0 PRESSURE REQUIRED AT CONTROLLING FIXTURE -25 PSI 1/2 2 1 -3.3 EMPTY 0 X 0.0 0.0 0.0 0.0 WATER DISTRIBUTION SIZING PIPE SIZE (IN) GPM FU (FT) FU (FV) VELOCITY (FT/S) EMPTY 0 X 0.0 0.0 0.0 0.0 TOTAL PRESSURE AT BUILDING INLET 56 PSI FRICTION LOSS 13.3 PSI PER 100 FEET, MAXIMUM VELOCITY OF 5 FEET/SECOND EMPTY 0 X 0.0 0.0 0.0 0.0 PRESSURE LOSS THROUGH ADDITIONAL EQUIPMENT -13 PSI DOMESTIC HOT WATER PIPE SIZING (PER CPC TABLE A-2 & CHART A-4) EMPTY 0 X 0.0 0.0 0.0 0.0 PRESSURE LOSS THROUGH METER (PER SITE GPM)-2 PSI SINK 1 X 2.0 2.0 2.0 2.0 PRESSURE GAIN/LOSS DUE TO ELEVATION, MAIN TO BUILDING -2 PSI 4 290 1668 1668 399 DRINKING FOUNTAIN 4 X 0.5 0.5 2.0 2.0 PRESSURE LOSS DUE TO FRICTION IN A 3-INCH DIAMETER SERVICE -2 PSI 3 165 719 666 227 HOSE BIBB, EACH ADDITIONAL 6 X 1.0 0.0 6.0 0.0 PRESSURE AVAILABLE AT BUILDING INLET 2 1/2 115 455 329 158.2 HOSE BIBB 1 X 2.5 0.0 2.5 0.0 RESIDUAL PRESSURE AT MAIN IN STREET 75 PSI 2 74 245 124 101.8 MOP BASIN 1 X 3.0 3.0 3.0 3.0 FLOW RATE IN WATER SERVICE MAIN TO BUILDING INLET (SITE WATER)75 GPM 1 1/2 35 66 20 48.2 LAVATORY 6 X 1.0 1.0 6.0 6.0 DEVELOPED LENGTH OF WATER SERVICE FROM MAIN TO BUILDING (SITE WATER) 350 FT 1 1/4 22 34 5 30.3 URINAL, 0.125 GPF F.V.2 X 4.0 2.0 8.0 4.0 DIFFERENCE IN ELEVATION FROM BUILDING INLET TO CONTROLLING FIXTURE 15 FT 1 13 18 0 17.9 WATER CLOSET, 1.28 GPF F.V.10 X 5.0 4.0 50.0 40.0 DIFFERENCE IN ELEVATION FROM MAIN TO BUILDING INLET 5 FT 3/4 6 7 0 8.3 FIXTURE TYPE (PUBLIC)QUA.X DWSFU DFU WSFU
SUB-TOTAL
DFU
SUB-TOTAL SIZE OF WATER SERVICE (DIAMETER)3 IN 1/2 2 1 0 2.8 DOMESTIC WATER GPM LOAD CALCULATION (CPC TABLE A 103.1)BUILDING WATER DEMAND 60 GPM PIPE SIZE (IN) GPM FU (FT) FU (FV) VELOCITY (FT/S) INFORMATION NEEDED FOR WATER SERVICE SIZING FRICTION LOSS 5 PSI PER 100 FEET, MAXIMUM VELOCITY OF 8 FEET/SECOND PRV REQUIR... Y/N SET PRESSURE ? PSI DOMESTIC COLD WATER PRESSURE CALCULATION DOMESTIC COLD WATER PIPE SIZING (PER CPC TABLE A-2 & CHART A-4) METER INFO SIZE 3 IN PIPE MATERIAL COPPER Date of Calc.7/23/2025 STREET PRESSURE STATIC 82 PSI RESIDUAL 75 PSI TEST DATE 12/16/2022 SPACE EXHIBIT BUILDING 4 185 840 -4.7
3 105 406 -4.8
PRESSURE SELECTED FOR UNIFORM LOSS 5 PSI/100FT 2 1/2 74 245 -4.8 PRSSURE AVAILABLE FOR UNIFORM LOSS 34 PSI/100FT 2 48 119 -4.9 GPM Calculations based on Flush Valves DEVELOPED LENGTH OF HORIZONTAL WATER PIPING WITHIN THE BUILDING 50 FT 1 1/2 27 46 -4.9 CONVERT TO GPM =21 -PRESSURE AVAILABLE FOR PIPE SIZING 17 PSI 1 1/4 19 28 -5 TOTAL FIXTURE UNITS = 4.0 4.0 PRESSURE LOSS THROUGH ADDITIONAL EQUIPMENT (PRV, MV, BFP OR OTHER)-4 PSI 1 12 16 -4.9 EMPTY 0 X 0.0 0.0 0.0 0.0 PRESSURE LOSS DUE TO ELEVATION, BUILDING INLET TO CONTROLLING FIXTURE -7 PSI 3/4 6 7 -4.4 EMPTY 0 X 0.0 0.0 0.0 0.0 PRESSURE REQUIRED AT CONTROLLING FIXTURE -30 PSI 1/2 2 1 -3.3 EMPTY 0 X 0.0 0.0 0.0 0.0 WATER DISTRIBUTION SIZING PIPE SIZE (IN) GPM FU (FT) FU (FV) VELOCITY (FT/S) EMPTY 0 X 0.0 0.0 0.0 0.0 TOTAL PRESSURE AT BUILDING INLET 58 PSI FRICTION LOSS 34 PSI PER 100 FEET, MAXIMUM VELOCITY OF 5 FEET/SECOND EMPTY 0 X 0.0 0.0 0.0 0.0 PRESSURE LOSS THROUGH ADDITIONAL EQUIPMENT -13 PSI DOMESTIC HOT WATER PIPE SIZING (PER CPC TABLE A-2 & CHART A-4) EMPTY 0 X 0.0 0.0 0.0 0.0 PRESSURE LOSS THROUGH METER (PER SITE GPM)-2 PSI SINK 2 X 2.0 2.0 4.0 4.0 PRESSURE GAIN/LOSS DUE TO ELEVATION, MAIN TO BUILDING -2 PSI 4 290 1668 1668 399 DRINKING FOUNTAIN 0 X 0.5 0.5 0.0 0.0 PRESSURE LOSS DUE TO FRICTION IN A 3-INCH DIAMETER SERVICE 0 PSI 3 165 719 666 227 HOSE BIBB, EACH ADDITIONAL 0 X 1.0 0.0 0.0 0.0 PRESSURE AVAILABLE AT BUILDING INLET 2 1/2 115 455 329 158.2 HOSE BIBB 0 X 2.5 0.0 0.0 0.0 RESIDUAL PRESSURE AT MAIN IN STREET 75 PSI 2 74 245 124 101.8 MOP BASIN 0 X 3.0 3.0 0.0 0.0 FLOW RATE IN WATER SERVICE MAIN TO BUILDING INLET (SITE WATER)75 GPM 1 1/2 35 66 20 48.2 LAVATORY 0 X 1.0 1.0 0.0 0.0 DEVELOPED LENGTH OF WATER SERVICE FROM MAIN TO BUILDING (SITE WATER) 200 FT 1 1/4 22 34 5 30.3 URINAL, 0.125 GPF F.V.0 X 4.0 2.0 0.0 0.0 DIFFERENCE IN ELEVATION FROM BUILDING INLET TO CONTROLLING FIXTURE 15 FT 1 13 18 0 17.9 WATER CLOSET, 1.28 GPF F.V.0 X 5.0 4.0 0.0 0.0 DIFFERENCE IN ELEVATION FROM MAIN TO BUILDING INLET 5 FT 3/4 6 7 0 8.3 FIXTURE TYPE (PUBLIC)QUA.X DWSFU DFU WSFU
SUB-TOTAL
DFU
SUB-TOTAL SIZE OF WATER SERVICE (DIAMETER)3 IN 1/2 2 1 0 2.8 DOMESTIC WATER GPM LOAD CALCULATION (CPC TABLE A 103.1)BUILDING WATER DEMAND 21 GPM PIPE SIZE (IN) GPM FU (FT) FU (FV) VELOCITY (FT/S) INFORMATION NEEDED FOR WATER SERVICE SIZING FRICTION LOSS 5 PSI PER 100 FEET, MAXIMUM VELOCITY OF 8 FEET/SECOND PRV REQUIR... Y/N SET PRESSURE ? PSI DOMESTIC COLD WATER PRESSURE CALCULATION DOMESTIC COLD WATER PIPE SIZING (PER CPC TABLE A-2 & CHART A-4) METER INFO SIZE 3 IN PIPE MATERIAL COPPER Date of Calc.7/23/2025 STREET PRESSURE STATIC 82 PSI RESIDUAL 75 PSI TEST DATE 12/16/2022 STEM CLASSROOM BUILING
CMMWREF.TVTVCGPRINT
NS - 1792885.184000
REVIT CONTROL POINT
EW - 6520966.684000
Elev - 8'-1 7/16"959596969 6
12400 COLUMBIA
WAY
WVLTPP
PP
PP
PP
CVLTDGDG
DG
DGDGDG989797979797979898989897979 7
9796979898979 7
9696969796989896979898SD
S
S
D
D
N 1792873.09E 6520967.53BUILDING FOOTPRINTAREA=10,775 SQ. FT.UTIL ENCLOSUREFOOTPRINTAREA=1,078 SQ.FT.TAX APN:6256-004-903S'LY LINE LOT 3, MR 30-34 PARCEL 1M.B. 273-73/75 C O L U M B I A W A Y20 FT EASEMENT FOR UTILITYPURPOSES IN FAVOR OF THE CITY OFDOWNEY; IN THE EASEMENT AGREEMENTBETWEEN THE CITY OF DOWNEY ANDTHE UNITED STATES OF AMERICA; D-12 44 40'
80'COLUMBIA WAYPROPERTY LINELIMIT OF WORKPROPERTY LINE LIMIT OF WORKCONGRESSMAN STEVE HORN WAY
PROPOSED
2 STORY BUILDING
PROPOSED 1
STORY
CLASSROOMS
ROOF PROJECTION ABOVE
2" CW
I.E = -2' -1" BFF
6" F
I.E = -3' -3" BFF
6" F
I.E = -3' -3" BFF
4" SS-U
I.E = -4' -0" BFF
6" SD-U
I.E = -1' -6" BFF 6" SD-U
I.E = -1' -6" BFF 6" SD-U
I.E = -1' -6" BFF 6" SD-U
I.E = -1' -6" BFF 6" SD-U
I.E = -1' -6" BFF
6" SD-U
I.E = -1' -6" BFF 6" SD-U
I.E = -1' -6" BFF
4" SD-U
I.E = -1' -6" BFF
1" CW
I.E = -1' -4" BFF
P-0001
P-0001 P-0001 P-0001
P-0001
P-0001
P-0001 P-0001 P-0001
P-0001P-0001
4,680 SQ. FT.4,680 SQ. FT.4,680 SQ. FT.
4,680 SQ. FT.
4,680 SQ. FT.
4,680 SQ. FT.4,680 SQ. FT.
P-0001
P-0001
FF 97.50
N.I.C.
N.I.C.
P-00012" SS-U
I.E = -1' -6" BFF
2 D.F.U
2 D.F.U
2,553 SQ. FT.
4 W.S.F.U
57 D.F.U
79.5 W.S.F.U
P-00012" SS-U
I.E = -2' -0" BFF
KEYNOTES
LEGEND
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
GENERAL NOTES
1. BEFORE COMMENCEMENT OF WORK, THE CONTRACTORS SHALL VERIFY THE EXACT
LOCATIONS, ELEVATIONS AND CHARACTERISTICS OF ALL UTILITIES AND PIPING AND SHALL IMMEDIATELY NOTIFY THE ARCHITECT OF ANY DISCREPANCIES.
2. REFER TO THE CIVIL ENGINEERING PLANS FOR ADDITIONAL INFORMATIONS NOT SHOWN ON THESE PLANS.
3. COORDINATE ALL UTILITY PIPING INSTALLATION WITH STRUCTURAL FOUNDATION PRIOR TO INSTALLATION OF PIPING.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
PLUMBING SITE
PLAN
P0.40
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNN
TRUE NORTH PROJECT NORTH
1" = 20'-0"
SITE PLAN 05
ITEM DESCRIPTION
P-0001 POINT OF CONNECTION. SEE CIVIL PLANS FOR CONTINUATION.
1 1
2 2
3 3
4 5
5 6
6 7
7 8
8 9
9 A A
F F
11 10
10 12
G G
B B
C C
D D
E E
2" CW6" F
FD-2
FS-1
FCO-1
1" CW
6" F
4" SS-U
P-0234
P-0234P-0234
P-0234
FCO-1
4" SD-U
P-0234
P-0234
FD-1
FD-1
P-0234 P-0234 P-0234 P-0234 P-0234 P-0234 P-0234
6" SD-U 6" SD-U 6" SD-U 6" SD-U 6" SD-U 6" SD-U 6" SD-U4" SS-U4" SS-U 4" SS-U4" SS-U4" SS-U
2" SS-U
4" SS-U
2" SS-U
2" SS-U
4" SS-U4" SS-U
2" SS-U
4" SS-U2" SS-U
2" SS-U
P-3002
P-3002
P-3004
P-4103 P-4103 P-4103 P-4103 P-4103 P-4103 P-4103
P-4103
6" SD-U 6" SD-U 6" SD-U 6" SD-U 6" SD-U 6" SD-U 6" SD-U 4" SD-U
2" SS-U
P-3002
(TYP. 5)
P-3002
P-3002
(TYP. 4)
2" SS-U
P-3002
FS-1
P-3002
3" SS-U
P-3004
4" SS-U
P-3002
FD-1 FD-1
P-3002
P-3002
P-3002
2" SS-U
4" SS-U
P-3002
2" SS-U
(TYP. 2)
P-3002 4" SS-U
P-3002
(TYP. 2)
2" SS-U
P-3002 2" SS-U
P-2102
2" CW
P-2102
1" CW
P-3002
P-3002
2" SS-U
2" SS-U
P-0234
2" SS-U
1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0"1/4" / 1'-0" P-0234
2" SS-U
KEYNOTESLEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
REFER TO THE GENERAL NOTES SECTION OF SHEET P0.10 FOR OVERALL GENERAL NOTES REGARDING THIS PROJECT.1.
FOR CONTINUATION OF UTILITIES SEE SHEET P0.40 - PLUMBING SITE PLAN SHEET.2.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
UNDERGROUND
PLUMBING PLAN
P2.00
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
ITEM DESCRIPTION
P-0234 POC WITH CIVIL. FOR CONTINUATION SEE SHEET P0.40.
P-2102 COLD WATER UP TO FINISH FLOOR ABOVE.
P-3002 SANITARY SOIL/WASTE DOWN FROM FLOOR ABOVE.
P-3004 SANITARY WALL CLEAN OUT DOWN FROM FLOOR ABOVE,
P-3111 SANITARY VENT UP TO VENT THRU ROOF.
P-4103 DOWNSPOUT DOWN FROM ABOVE TO TRANSITION TO BELOW STORM DRAINAGE. REFER TO ARCHITECTURAL PLANS.
CMMWREF.TVTVCGPRINT
1 1
2 2
3 3
4 5
5 6
6 7
7 8
8 9
9 A A
F F
11 10
10 12
G G
B B
C C
D D
E E
STAFF
ROOM
102
MEN'S
RESTROOM
106
MECHANICAL
ROOM
103
ELECTRICAL
ROOM
104
IDF
ROOM
105
FAMILY
RESTROOM
108
NURSING
ROOM
116
WOMEN'S
RESTROOM
107
EXHIBIT
SPACE
100
STORAGE
101
ELEVATOR
111
ELEVATOR
MACHINE
ROOM
110
AHU-1
AHU-2
P4.11
02 P4.11
10 VFC-1
VFC-4
VFC-3
VFC-2
STEM
CLASSROOM
113
STEM
CLASSROOM
112
P4.11
18 P4.11
19 P4.12
02 P4.12
14 P4.11
04 P4.11
12 DSB-1DSB-1 DSB-1 DSB-1 DSB-1 DSB-1 DSB-12" CW2" V2" CW3/4" CW 2" V
P-3607
P-3608
3/4" CD
P-3610
P-3607
P-3610
3/4" CD
P-3608
FC-2
FC-1
3/4" CD
(20 TON)
(40 TON)
(3 TON)
(3 TON)
(3 TON)(3 TON)3/4" CD3/4" CD
3/4" CD
P-3604
P-3604
1" CD
P-3613
(TYP. 2)
P-3605P-3607
P-3608
4,680 SQ. FT.4,680 SQ. FT.4,680 SQ. FT.4,680 SQ. FT.4,680 SQ. FT.4,680 SQ. FT.4,680 SQ. FT. (2 TON)
(2 TON)
P-3605
P-3611
P-3611
P-3605
3/4" CD
3/4" CD
2" VFW spigot
KEYNOTESLEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
REFER TO THE GENERAL NOTES SECTION OF SHEET P0.10 FOR OVERALL GENERAL NOTES REGARDING THIS PROJECT.1.
FOR CONTINUATION OF UTILITIES SEE SHEET P0.40 - PLUMBING SITE PLAN SHEET.2.
EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.
3. LOCATIONS SHOWN FOR POC'S TO MECHANICAL UNITS ARE APPROXIMATE. COORDINATE EXACT ROUGH-IN LOCATIONS AND REQUIREMENTS WITH THE INSTALLING MECHANICAL HVAC CONTRACTOR PRIOR TO INSTALLATION. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
4. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFERENCE WITH ELECTRICAL AND MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING.
5. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING ACCESS PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN AND THE ELECTRICAL LIGHTING LAYOUT.
6. ALL VALVES, TRAP PRIMER, WATER HAMMER ARRESTERS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON- ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL.
7. NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
FIRST FLOOR
PLUMBING PLAN
P2.01
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
ITEM DESCRIPTION
P-0234 POC WITH CIVIL. FOR CONTINUATION SEE SHEET P0.40.
P-3604 CONDENSATE DRAIN CONNECTION TO WALL MOUNTED MECHANICAL UNIT - SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
P-3605 CONDENSATE DRAIN CONNECTION TO MECHANICAL UNIT - PROVIDE CONDENSATE DRAIN
PUMP ON UNIT AS REQUIRED - SEE MECHANICAL DRAWINGS FOR ADDITIONAL P-3607 ROUTE 1/2" PUMPED CONDENSATE DRAIN FROM FAN COIL UNIT UP TO ABOVE CEILING SPACE.
P-3608 1/2" PUMPED CONDENSATE DRAIN IN CEILING SPACE, DOWN TO CONNECT TO THE TOP QUADRANT OF GRAVITY FED CONDENSATE DRAIN - SIZE AS NOTED.
P-3610 CONDENSATE DOWN IN WALL WITH INDIRECT WASTE CONNECTION TO LAVATORY TAILPIECE.
P-3611 CONDENSATE DOWN IN WALL WITH INDIRECT WASTE CONNECTION TO SINK TAILPIECE.
P-3613 CONDENSATE DOWN TO POINT OF DISCHARGE OVER FLOOR SINK WITH MIN 2" AIR GAP.
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
11 10
10 12
G G
B B
C C
D D
E E
P-31124" V
OPEN
EXHIBIT
SPACE
200
3" V
P-31114" V
P-31043" V
ROOF
ACCESS
201
P-3105
1/2" / 1'-0"
1/2" / 1'-0"
1/2" / 1'-0"
KEYNOTESLEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
STORM DRAIN ARE SIZED IN ACCORDANCE WITH THE 2022 CALIFORNIA PLUMBING CODE, TABLE 1103.2, AND IS BASED ON A RAINFALL RATE OF 4" (IN) PER HOUR.
2. MAIN BUILDING STORM DRAINAGE IS PART OF THE PRE-ENGINEERED METAL BUILDING DESIGN BY OTHERS.3.
REFER TO THE GENERAL NOTES SECTION OF SHEET P0.10 FOR OVERALL GENERAL NOTES REGARDING THIS PROJECT.1.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SECOND FLOOR
PLAN AND STEM
ROOF PLAN
P2.02
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
ITEM DESCRIPTION
P-3104 SANITARY VENT UP FROM BELOW FLOOR.
P-3105 SANITARY VENT TO ROUTE HIGH IN CEILING SPACE.
P-3111 SANITARY VENT UP TO VENT THRU ROOF.
P-3112 VENT THROUGH ROOF.
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
B B
C C
D D
E E
P-31124" V1/2" / 1'-0"1/2" / 1'-0"1/2" / 1'-0"1/2" / 1'-0"1/2" / 1'-0"1/2" / 1'-0"1/2" / 1'-0"1/2" / 1'-0"1/2" / 1'-0"KEYNOTESLEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
STORM DRAIN ARE SIZED IN ACCORDANCE WITH THE 2022 CALIFORNIA PLUMBING CODE, TABLE 1103.2, AND IS BASED ON A RAINFALL RATE OF 4" (IN) PER HOUR.
2. MAIN BUILDING STORM DRAINAGE IS PART OF THE PRE-ENGINEERED METAL BUILDING DESIGN BY OTHERS.3.
REFER TO THE GENERAL NOTES SECTION OF SHEET P0.10 FOR OVERALL GENERAL NOTES REGARDING THIS PROJECT.1.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025 1/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ROOF PLUMBING
PLAN
P2.03
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
ITEM DESCRIPTION
P-3112 VENT THROUGH ROOF.
CMREF.CGCMREF.CGKEYNOTESLEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
REFER TO THE GENERAL NOTES SECTION OF SHEET P0.10 FOR OVERALL GENERAL NOTES REGARDING THIS PROJECT.1.
FOR CONTINUATION OF UTILITIES SEE SHEET P0.40 - PLUMBING SITE PLAN SHEET.2.
EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.
3. LOCATIONS SHOWN FOR POC'S TO MECHANICAL UNITS ARE APPROXIMATE. COORDINATE EXACT ROUGH-IN LOCATIONS AND REQUIREMENTS WITH THE INSTALLING MECHANICAL HVAC CONTRACTOR PRIOR TO INSTALLATION. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
4. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFERENCE WITH ELECTRICAL AND MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING.
5. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING ACCESS PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN AND THE ELECTRICAL LIGHTING LAYOUT.
6. ALL VALVES, TRAP PRIMER, WATER HAMMER ARRESTERS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON- ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL.
7. 7
7 A A
B B
C C
MEN'S
RESTROOM
106
FAMILY
RESTROOM
108
NURSING
ROOM
116
WOMEN'S
RESTROOM
107
STORAGE
101
WC-2WC-1WC-1
WC-2WC-1WC-1WC-1WC-1
UR-1UR-2
WC-2
L-1
FD-1
FD-1
FS-1
L-1
WC-2
FD-1
FD-1
S-1
DF-1
2" V3" VS-2
4" SS-U
WCO
4" SS-U
2" SS-U
2" V
2" V4" SS-U4" SS-U2" V2" V4" SS-U2" VSS-1
L-2 L-2
WCO
(TYP. 5)
3" V
2" V
2" V
L-2 L-2
2" SS-U
2" V
P-3012
(TYP. 5)
P-3010
2" V4" SS-U
P-3010
WCO WCO
(TYP. 2)
P-3010
(TYP. 4)
WCO WCO
P-3011
4" SS-U
WCO WCO
P-3010
(TYP. 2)
P-3010
(TYP. 2)
WCO
P-3010
P-3010
(TYP. 2)P-3012
WCO
P-3010
P-3103
3" V
P-3010
WS-1
7 7
A A
B B
C C
WC-2WC-1WC-1
WC-2WC-1WC-1WC-1WC-1
UR-1UR-2
WC-2
L-1
SS-1
TP-1
WHA-1
WHA-1
TP-1
FD-1
FD-1
CP-1
FS-1
L-1
WC-2
TP-1
WHA-1
WHA-1
TP-1
MEN'S
RESTROOM
106
FAMILY
RESTROOM
108
NURSING
ROOM
116
WOMEN'S
RESTROOM
107
STORAGE
101
FD-1 FD-1
S-1
2" CW2" CW1 1/4" HWL-2
L-2
L-2
L-2
S-2
3/4" CW2" CW2" CW
DF-1
IMB-1
3/4" HW3/4" CW
2" CW
TMV-1
ET-1
EWH-1
1/2" TP
1/2" TP
(TYP. 2)
P-2116
P-2116
P-2114
TMV-1
P-2115
P-2115
P-2111
1 1/2" CW
P-2111
1 1/2" CW
STAFF
RESTROOM
114
P-2114
TMV-1
P-2115
P-2115
P-2114
P-2111
P-2111
2" CW
2" CW
1" HW
1" HW
3/4" HW
1 1/2" CW
WS-1
9 9
B B
C C
MECHANICAL
ROOM
1033/4" CWETP-1
FS-1
FD-2
1/2" TP
1/2" TP
IDF
ROOM
105
STORAGE
101
P-2114
9 9
B B
C C
MECHANICAL
ROOM
1034" SS-U2" VFCO-1
FS-1
FD-2
FCO-1
2" V
4" SS-U
AHU-2
AHU-1
ETP-1
P-3010
P-3010
E E
2" V
4" SS-U
ELEVATOR
MACHINE
ROOM
110
STAFF
ROOM
102
FIRE
RISER
115
ETP-1
WCO
P-3012
HUB-DRAIN
E E
ELEVATOR
MACHINE
ROOM
110
STAFF
ROOM
102
FIRE
RISER
115
ETP-1
HUB-DRAIN
P-2118
2" CW
P-2114
6" F
2" CW
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ENLARGED
PLUMBING PLANS
P4.11
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING1/4" = 1'-0" ENLARGED CORE RESTROOM DRAINAGE PLAN 021/4" = 1'-0"
ENLARGED CORE RESTROOM WATER PLAN 10
ITEM DESCRIPTION
P-2111 COLD WATER DOWN IN WALL TO FULL SIZE HEADER WITH SHUT OFF VALVE BEHIND ACCESS PANEL.
P-2114 3/4" COLD WATER DOWN TO FIXTURE.
P-2115 3/4" COLD AND HOT WATER DOWN TO THERMOSTATIC MIXING VALVE. ROUTE TEMPERED WATER TO FIXTURE.
P-2116 3/4" COLD AND HOT WATER DOWN TO FIXTURE.
P-2118 COLD WATER UP TIGHT TO WALL TO 2'-0" ABOVE FINISHED FLOOR. PROVIDE SHUT-OFF BALL VALVE ON RISE.
P-3010 2" WASTE DOWN, 1-1/2" VENT UP.
P-3011 3" WASTE DOWN, 2" VENT UP.
P-3012 4" WASTE DOWN, 2" VENT UP.
P-3103 SANITARY VENT UP TO FLOOR ABOVE.
1/4" = 1'-0"
ENLARGED MECHANICAL ROOM WATER PLAN 19
1/4" = 1'-0"
ENLARGED MECHANICAL ROOM DRAINAGE PLAN 18
1/4" = 1'-0"ENLARGED FIRE RISER ROOM DRAINAGE PLAN 041/4" = 1'-0"ENLARGED FIRE RISER ROOM WATER PLAN 12
TVTVTVTVKEYNOTESLEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
REFER TO THE GENERAL NOTES SECTION OF SHEET P0.10 FOR OVERALL GENERAL NOTES REGARDING THIS PROJECT.1.
FOR CONTINUATION OF UTILITIES SEE SHEET P0.40 - PLUMBING SITE PLAN SHEET.2.
EXACT LOCATIONS AND MOUNTING HEIGHTS OF PLUMBING FIXTURES SHALL BE OBTAINED FROM THE ARCHITECTURAL DRAWINGS.
3. LOCATIONS SHOWN FOR POC'S TO MECHANICAL UNITS ARE APPROXIMATE. COORDINATE EXACT ROUGH-IN LOCATIONS AND REQUIREMENTS WITH THE INSTALLING MECHANICAL HVAC CONTRACTOR PRIOR TO INSTALLATION. SEE MECHANICAL DRAWINGS FOR ADDITIONAL INFORMATION.
4. ALL PLUMBING WORK SHALL BE INSTALLED SO AS TO AVOID INTERFERENCE WITH ELECTRICAL AND MECHANICAL EQUIPMENT AND STRUCTURAL FRAMING.
5. THE CONTRACTOR SHALL COORDINATE THE LOCATION OF ALL CEILING ACCESS PANELS WITH THE ARCHITECTURAL REFLECTED CEILING PLAN AND THE ELECTRICAL LIGHTING LAYOUT.
6. ALL VALVES, TRAP PRIMER, WATER HAMMER ARRESTERS OR OTHER EQUIPMENT SHOWN IN WALLS OR ABOVE NON- ACCESSIBLE CEILINGS SHALL BE INSTALLED BEHIND AN ACCESS PANEL.
7. F F
11 11
12 12
G G
SI-1
S-3
EWH-2
S-3
EWH-2
SI-1
DSB-1
2" V
4" V
WCO
WCO
P-3010
P-3010
4" SD-U
2,553 SQ. FT.
FC-2
FC-1
P-3111
STEM
CLASSROOM
112
STEM
CLASSROOM
113
2" SS-U
2" SS-U
F F
11 11
12 12
G G
STEM
CLASSROOM
112
STEM
CLASSROOM
113
P-21181" CW
1" CW
3/4" CW
P-2117
P-2117
S-3
EWH-2
S-3
EWH-2
SI-1
SI-1
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ENLARGED
PLUMBING PLANS
P4.12
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING1/4" = 1'-0"ENLARGED STEM CLASSROOM PLUMBING DRAINAIGE PLAN 021/4" = 1'-0"ENLARGED STEM CLASSROOM PLUMBING WATER PLAN 14
ITEM DESCRIPTION
P-2117 3/4" COLD WATER DOWN TO INSTA-HOT WATER HEATER. REFER TO DETAIL 19/P6.01 FOR CONTINUATION.
P-2118 COLD WATER UP TIGHT TO WALL TO 2'-0" ABOVE FINISHED FLOOR. PROVIDE SHUT-OFF BALL VALVE ON RISE.
P-3010 2" WASTE DOWN, 1-1/2" VENT UP.
P-3111 SANITARY VENT UP TO VENT THRU ROOF.
NOTES:
A.GENERAL.
2.PROVIDE SHOP DRAWINGS INDICATING LOCATIONS OF
ALL EXPOSED PLUMBING ELEMENTS IN RESTROOMS,
INCLUDING BUT NOT LIMITED TO ACCESS PANELS, WALL
CLEANOUTS, HOSE BIBBS, INSTANTANEOUS ELECTRIC
WATER HEATERS, TEHRMOSTATIC MIXING VALVES,
TRANSFORMERS, AND OTHER EXPOSED PLUMBING
ELEMENTS AS APPLICABLE. INDICATE ALL SUCH ITEMS
USING THE ARCHITECTURAL INTERIOR ELEVATIONS AS A
BACKGROUND, WITH ALL ITEMS DIMENSIONALLY
LOCATED AND DRAWN TO SCALE.
3.REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS,
ROUGH IN DIMENSIONS, AND MOUNTING HEIGHTS OF
FIXTURES, EQUIPMENT, AND OTHER EXPOSED PLUMBING
ELEMENTS.
a.REFER TO PLUMBING DRAWINGS FOR ADDITIONAL
INFORMATION.
b.IN THE EVENT OF A CONFLICT BETWEEN
ARCHITECTURAL AND PLUMBING DOCUMENTS, SEEK
ARCHITECT'S DIRECTION AND/OR APPROVAL PRIOR
TO INSTALLATION.
4.WHERE A COMMON PLUMBING WALL SERVES BOTH
MEN'S AND WOMEN'S RESTROOMS, ASSOCIATED
ACCESS PANELS AND CLEANOUTS SHALL BE LOCATED
ON THE MEN'S RESTROOM SIDE OF THE WALL.
5.ITEMS EXPOSED TO PUBLIC VIEW BELOW COUNTERS (I.E.:
COUNTER-MOUNTED LAVATORY LOCATIONS) SHALL BE
MOUNTED AS HIGH AS POSSIBLE TO MINIMIZE ANY VISUAL
IMPACT.
C.WALL ACCESS PANELS.
1.WHERE POSSIBLE, USE SAME ACCESS PANEL FOR
PLUMBING COMPONENTS LOCATED WITHIN WALL
DIRECTLY ADJACENT IN SAME IMMEDIATE VICINITY (I.E.:
WATER HAMMER ARRESTORS INSTALLED DIRECTLY
ADJACENT TO TRAP PRIMERS).
2.TYPICAL ACCESS PANELS SHALL BE 12"X12" SIZE, OR AS
NECESSARY FOR PROPER OPERATION AND
MAINTENANCE OF ITEMS INSTALLED WITHIN. WHERE
ACCESS PANELS LARGER THAN 12"X12" ARE REQUIRED,
CONTRACTOR SHALL SEEK ARCHITECT'S APPROVAL
PRIOR TO INSTALLATION.
5.CAREFULLY COORDINATE ALL ACCESS PANEL
LOCATIONS WITH OTHER TRADES PRIOR TO
INSTALLATION. PLUMBING COMPONENTS INSTALLED
WITHIN ACCESS PANELS SHALL BE COORDINATED WITH
THE FINALIZED ACCESS PANEL LOCATION SUCH THAT
ITEMS ARE CENTERED WITHIN OPENING AND ARE FULLY
ACCESSIBLE FOR OPERATION, MAINTENANCE, AND
REPAIR.
CL
CLCL
CLCL
CL
3.ACCESS PANELS SHALL BE INSTALLED IN A MANNER
SUCH THAT DOOR SWING IS NOT IMPEDED BY ANY
ADJACENT BUILDING ELEMENT. EXCEPTION: AT UNDER-
COUNTER LOCATIONS, ACCESS PANELS SHALL BE
MOUNTED AS HIGH AS POSSIBLE TO MINIMIZE VISUAL
IMPACT. IN SUCH CASES, IT IS ACCEPTABLE FOR THE
ACCESS PANEL TO BE LOCATED BEHIND A REMOVABLE
PORTION OF SOAP DISPENSER BOTTLE IF CONDITION
OCCURS.
CL
3" MIN. FROM WALL
OR PARTITION
(TYP)
WALL CLEANOUT
SERVING MAIN
SOIL/WASTE LINE
ITEMS EXPOSED TO PUBLIC
VIEW BELOW COUNTERS
SHALL BE MOUNTED AS HIGH
AS POSSIBLE TO MINIMIZE
ANY VISUAL IMPACT.
CL
CL
B.CLEANOUTS
1.CLEANOUTS SHALL BE MOUNTED AS LOW AS POSSIBLE
WHILE MAINTAINING ALIGNMENT WITH ADJACENT
EXPOSED PLUMBING ELEMENTS, BUT NOT LESS THAT 12"
ABOVE FINISHED FLOOR.
1.EXAMPLES SHOWN ARE TO ILLUSTRATE TYPICAL
INSTALLATION CRITERIA FOR EXPOSED PLUMBING
COMPONENTS IN RESTROOMS. SEE PLANS FOR SPECIFIC
LOCATIONS, QUANTITIES, AND TYPES OF ITEMS AS
APPLICABLE TO EACH RESTROOM. REFER TO CONTRACT
DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS NOT ADDRESSED IN THIS DETAIL.
4.ACCESS PANELS SHALL NOT OVERLAP PAINTED AND
NON-PAINTED SURFACES SUCH AS TILE OR TERRAZO,
AND SHALL BE MOUNTED SUCH THAT THE EDGE OF THE
ACCESS PANEL IS MINIMUM 3" FROM THE EDGE OF ANY
SUCH SURFACE.
CL
D.ELECTRONIC SENSOR OPERATED FLUSH VALVES, FAUCETS,
AND SOAP DISPENSERS
2.TRANSFORMERS SERVING SENSOR FAUCETS AND SOAP
DISPENSERS SHALL BE MOUNTED IN CONCEALED
LOCATION AT THE REAR UNDERSIDE OF COUNTER WITH
ALL WIRING CONCEALED AND RUN WITHIN CONDUIT IN
ORDER TO MINIMIZE ANY VISUAL IMPACT OR EXPOSURE
TO VANDALISM.
1.TRANSFORMERS SERVING MULTIPLE TOILETS AND
URINALS SHALL BE LOCATED BEHIND ONE CENTRAL
ACCESS PANEL.
CL
ALL ACCESS PANELS SHALL
BE HORIZONTALLY ALIGNED
IN A UNIFORM MANNER
SHUTOFF VALVE ACCESS
PANEL
WATER HAMMER ARRESTOR
AND TRAP PRIMER COMBINED
ACCESS PANEL
.
EQ.EQ.
EQ.EQ.12" MIN.12" MIN.12" MIN.3" MIN.3" MIN.SENSOR FLUSH VALVE
TRANSFORMER ACCESS
PANEL (WHERE
OCCURS)
EXPOSED PLUMBING ELEMENTS
SHALL ALIGN VERTICALLY AND/OR
HORIZONTALLY WHEREPOSSIBLE
WALL CLEANOUT
SERVING BANK OF
URINALS
3" MIN.3" MIN. (TYP.)
3" MIN.
EQ.EQ.
MIXING VALVE ACCESS
PANEL
WALL CLEANOUT
SHUTOFF VALVE AND/OR
MIXING VALVE ACCESS
PANEL
RECESSED HOSE BIBB OR
WALL FLANGE TYPE HOSE
BIBB AS APPLICABLE
WALL CLEANOUT
ADJACENT EXPOSED
PLUMBING ELEMENTS
SHALL BE HORIZONTALLY
ALIGNED IN A UNIFORM
MANNER
REFER TO SHEET B-A521 FOR
ADDITIONAL MOUNTING HEIGHTS.
FUSED DISCONNECT
SWITCH & POWER. SEE
ELECTRICAL DWGS.
FINISHED FLOOR
DIELECTRIC UNION (TYP)
THERMOMETER
CHECK
VALVE (TYP)
SOV (TYP)
ASME RATED
TEMPERATURE &
PRESSURE RELIEF
VALVE
SPACEMAKER E-100
SEISMIC RESTRAINT
SYSTEM (TYP OF 2)
ROUTE DRAIN LINE TO
APPROVED
RECEPTOR.
4" CONCRETE
HOUSEKEEPING PAD
CW
HW
BLV
EXPANSION TANK
MOUNTED ON WALL
WITH MAPA EXPANSION
TANK CAGE.
3/4" TPR DRAIN LINE
ET-1
WH-
CP-1
CEILING HWR
NOTE:
1. INSTALL WITH A MINIMUM AMOUNT OF EXPOSED
PIPING AS NECESSARY FOR DIRECT ACCESS TO
VALVES AND COMPONENTS. PIPING SHALL BE
CONCEALED WITHIN WALLS OR ABOVE FINISHED
CEILING WHERE POSSIBLE.
2. WATER HEATER STRAPPING SHALL BE AT POINTS
WITHIN THE UPPER ONE-THIRD AND LOWER ONE-
THIRD OF ITS VERTICAL DIMENSIONS. AT THE LOWER
POINT, A MINIMUM ONE-THIRD.
CIRCULATING PUMP WITH
INTEGRAL TIME SWITCH
AND AQUASTAT CONTROL.
LPA
SLOPE TO DRAIN
LOCATION. SEE PLANS
FOR CONTINUATION.
DIELECTRIC UNION
(IF REQUIRED)
MECHANICAL
UNIT
FLEXIBLE
CONNECTION
(IF REQUIRED)
TYPE "M"
COPPER TUBING
WITH WROUGHT
COPPER FITTING
CLEANOUT PLUG
(THREADED)
VENT SAME
SIZE AS DRAIN
CEILING
TERMINATE SECONDARY CONDENSATE DRAIN THRU CEILING
WITHIN A CHROME-PLATED, RECESSED ESCUTCHEON. PIPE
SHALL NOT BE VISIBLE BELOW THE CEILING LINE.
3/4"
MIN.
3".SECONDARY
DRAIN PAN
LPA
FINISHED FLOOR
3/4" BRAIDED
STAINLESS STEEL
HOSE
SINK OR LAVATORY
ESCUTCHEON
(TYP.)
WALL
CHROME PLATED
TAILPIECE WITH
DRAIN CONN.
HOSE CLAMP (TYP.)
"P" TRAP
COUNTERTOP
CABINET DOOR
RECESSED
TOE KICK
CONDENSATE
DRAIN IN WALL
WASTE
DRAIN IN
WALL
LPA
NOTE: SEE 01/S601 FOR ADDITIONAL INFORMATION
FINISHED FLOOR
FINISHED GRADE
SLAB ON GRADE
MINIMUM 6"
INV PER
PLANS
EXTERIOR WALL
PROVIDE SLEEVES OR
OPENINGS FOR ALL PIPES
PASSING THROUGH
CONCRETE WALL WITH ID
2" LARGER THAN PIPE.
PENETRATION THROUGH CONCRETE
STRUCTURAL ELEMENTS SHALL BE DOUBLE HALF
LAP WRAPPED WITH 0.125 INCH THICK "ARMOFLEX"
INSULATING TAP
FINISHED FLOOR
FINISHED GRADE
SLAB ON GRADE
INV PER
PLANS
EXTERIOR WALL
PROVIDE SLEEVES OR OPENINGS
FOR ALL PIPES PASSING
THROUGH CONCRETE WALL
WITH ID 2" LARGER THAN PIPE.6" MINLPA
NOTES:
1. INSULATE ALL FITTINGS, VALVES, CHECK VALVE, PIPE AND PUMP BODY. EXTEND MEASUREMENT PORT TO EXTERIOR OF INSULATION.
2. RECIRCULATION BOOSTER PUMP SHALL BE LEAD-FREE CONSTRUCTION.
3. 7-DAY PROGRAMMABLE TIMER SHALL BE SET TO ALLOW PUMP OPERATION ONLY DURING OCCUPIED HOURS.
4. AQUASTAT CONTROLLER SHALL BE SET TO DISENGAGE THE PUMP WHEN THE RETURN WATER TEMPERATURE IS ABOVE 105 F OR AS ALLOWED BY LOCAL ENERGY CODE.
5. PROVIDE AUTOMATIC AIR VENT AS REQUIRED BY LOCAL ENERGY CODE TO REDUCE CAVITATION. ROUTE DRAIN LINE TO APPROVED DRAINAGE RECEPTOR. INSTALL AIR VENT WITHIN 48" OF PUMP INLET AS REQUIRED TO REDUCE.
THERMOMETER, (TYP.)
HOT WATER
RETURN
HOT WATER RETURN
TO WATER HEATER
UNION, (TYP.)
SWING
CHECK
VALVE
.
.
ACORN MODEL 8126-LF
HOSE BIBB WITH
VACUUM BREAKER
CP-1
PRESSURE &
TEMPERATURE
TEST TAP (TYP.)
AQUASTAT BULB
IN THERMOWELL
BALL VALVE (TYP.)
CROSS FITTING
AQUASTAT
CONTROLLER
DIGITAL 7-DAY PROGRAMMABLE TIMER
AQUASTAT BULB IN THERMOWELL
120V
POWER
CAPILLARYAS REQUIREDHEIGHTCLEANOUT
TYPE 'L' COPPER WITH
WROUGHT COPPER FITTINGS
.
1/8" FT.
POSITIVELY ATTACH TUBING TO
"Y" FITTING WITH HOSE CLAMP
"Y" FITTING
CEILING
ROUTE DRAIN TO
APPROVED LOCATION,
REFER TO PLANS
1/2" PCD (PUMPED
CONDENSATE DRAIN)
CONDENSATE
DRAIN PAN
FACTORY SUPPLIED
CONDENSATE PUMP
MOUNTED IN UNIT
OUTLINE OF WALL
MOUNTED FAN COIL UNIT
1/2" PCD CONNECTION
AT PUMP DISCHARGE
LAVATORY OR
SINK
RIGID COLD
WATER SUPPLY
J-BOX
COUNTER TOP
RIGID HOT
WATER SUPPLY
P
E
ITEM INDICATED ON THE
PLUMBING DRAWINGS
AND SPECIFIED IN THE
PLUMBING SECTIONS OF
THE SPECIFICATIONS.
ITEM INDICATED ON THE
ELECTRICAL DRAWINGS
AND SPECIFIED IN THE
ELECTRICAL SECTIONS
OF THE SPECIFICATIONS.
EWH-2
PE
LPA
INSTANTANEOUS
WATER HEATER
1/4 TURN
ANGLE STOP
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
PLUMBING DETAILS
P6.01
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN.T.S.
TYPICAL EXPOSED PLUMBING ELEMENTS IN RESTROOMS 01
N.T.S.ELECTRIC WATER HEATER W/ RECIRC. PUMP 02
N.T.S.CONDENSATE DRAIN W/
SECONDARY DRAIN PAN 03N.T.SCONDENSATE DRAIN TO TRAP 07
N.T.S.PIPE PENATRATION 18 NTSCIRCULATION PUMP INSTALLATION SCHEMATIC 10 NTSFAN COIL CONDENSATE PUMP PIPING DETAIL 11N.T.S.INSTANTANEOUS WATER HEATER 19
2"AIR GAP2" VENT
4" x 2"
REDUCER
CLEANOUT
4" WYE
SAN TEE
CAULK ALL
AROUND
FIN. FLOOR
ANCHOR TO
WALL (TYP.)
4" LONG SWEEP
C.I. BEND
4" DEEP SEAL "P" TRAP
6" x 4" INCREASER
NO-HUB COUPLING WITH
4-BAND STAINLESS STEEL
CLAMP AND SHIELD (TYP.)
6" C.I. SOIL PIPE24"-2" SPRINKLER SYSTEM DRAIN
CENTERED OVER 6" C.I. PIPE
COLD WATER FROM
TRAP PRIMER, SPILL
INTO 6" C.I. PIPE
DOMESTIC COLD
WATER SUPPLY LINE
ACCESS PANEL
TRAP PRIMER VALVE.
INSTALL PER MANUFACTURER'S
INSTALLATION INSTRUCTIONS
WALL
1/2"CW COPPER PIPING IN WALL
(SEE PLUMBING SPECIFICATIONS)
FINISHED FLOOR
FLOOR DRAIN WITH DEEP SEAL FLOOR
TRAP & TRAP PRIMER CONNECTION
(SEE PLUMBING SPECIFICATION)
1/2"CW PIPING
BELOW FLOOR
BARE PIPE
REFER TO DETAIL #17/A8.21
FOR ALL FLASHING AND
INSULATION INFORMATION
TYP. ROOFING
ASSEMBLY, REFER
TO DETAIL #17/A8.21
DECK ASSEMBLY PER
STRUCTURAL ROOF PLANS
VANDAL-RESISTANT
VENT CAP FOR VTR
(ZURN MODEL Z193)
A
A
NOTE:
MIN. HEIGHT = 0'-6"
MAX. HEIGHT = 1'-6"
THREADED ROD HANGER (SEE NOTE #2)
LOCKING NUT
SUPPORT NUT
B-LINE B3100F CLEVIS HANGER
14 GAGE ZINC COATED SADDLE.
SEISMIC AIRCRAFT CABLE BOTH SIDE
OF UNISTRUT (SEE NOTE #3). 4 DIRECTION
SPLAYED AT 45 DEGREES AT SINGLE PIPE
PIPE. MAX DIAMETER OF PIPE TO BE 4"
(SEE PLANS FOR SIZES)
UPPER ATTACHMENT (SEE NOTE #2)
NOTES:
1. MAXIMUM HORIZONTAL HANGER SPACING FOR 1-1/4" PIPING AND SMALLER TO BE 5'-0" AND 1-1/2" PIPING AND LARGER TO BE 8'-0".
2. SEE STRUCTURAL HANGER DETAILS 01/S6.92 FOR ROD HANGER DETAILS.
3. 1/4" DIA AIRCRAFT CABLE PER DETAIL 03/S6.92. PROVIDE CABLE BRACING ON EACH SIDE OF UNISTRUT/HANGER. • PROVIDE TRANSVERSE BRACING AT 16'-0" MAX, O.C. EACH DIRECTION. MINIMUM (2) ON EACH STRAIGHT RUN. • PROVIDE LONGITUDINAL BRACING AT 24'-0" MAX. O.C. EACH SIDE OF UNISTRUT/HANGER, EACH DIRECTION. MINIMUM (1) ON EACH STRAIGHT RUN. 1 2
3 4
5 7
8 2" MIN.
2 3
5 8
9 10
1 2
3 4
5 6
7 8
9 10
STRUCT CLAMP OR U-BOLT
P1001 UNISTRUT. MAX SPAN 4'-0".
MAX. WEIGHT 1,000 LBS
6 1
7 LPA
6 DISHWASHER
(BY OTHERS)
COUNTER TOP
AIR GAP FITTING
FOOD WASTE DISPOSER, REFER
TO PLUMBING FIXTURE
SCHEDULE FOR SPECIFICATION
MCGUIRE No. PW8089NCO 1-1/2"
P-TRAP W/ PRE-WRAPED TRAP
AND SUPPLY COVERS
KITCHEN
SINK
COUNTER TOP
FINISHED FLOOR
ANGLE STOP (TYP)HOT WATER SUPPLY
WITHIN WALL
COLD WATER SUPPLY
WITHIN WALL
McGUIRE MODEL No.
151 BRASS BASKET
STRIANER
GENERAL NOTES
1. APPLIES TO UNDERMOUNT AND SELF RIMMING
INSTALLATIONS.
2. THIS DETAIL IS TYPICAL FOR INSTALLATIONS WITH
THE COFFEE MAKER OR WATER DISPENSER ON
EITHER SIDE OF THE SINK, REFER TO
ARCHITECTURAL PLANS FOR EXACT LOCATION.
FILTERED COLD
WATER SUPPLY
3/4" DIA. HOLE IN COUNTER,
COORDINATE EXACT LOCATION IN
FIELD WITH COFFEE MAKER LOCATION
1/2" CW LINE
1/2" TO 1/4" REDUCER
1/4" WATER LINE, STUB FOR
FUTURE INSTALLATION IF
COFFEE MAKER NOT PRESENT
1/2" CW LINE
1/2" TO 1/4"
REDUCER
WATER FILTER
COFFEE
MAKER
(OFOI)
WS-1
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% CONSTRUCTION DOCS 08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
PLUMBING DETAILS
P6.02
01/06/2023
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNTS
FIRE SPRINKLER STANDPIPE DRAIN 01
NTS
TRAP PRIMER CONNECTION DETAIL 02
NTSVENT THRU ROOF DETAIL 03
NTS
SINGLE PIPE AND TRAPEZE HANGER DETAIL 05
N.T.S.
TYPICAL BREAKROOM SINK LAYOUT 06
ABBREVIATIONS
4S/DP
ACT
ADA
A.F.F.
A.F.G.
AWG
AMP, A
A.I.C.
AF/AT
AHJ
AS/AF
ATS
AVG
4" SQUARE BY 2 1/8" DEEP BOX
ACOUSTICAL CEILING TILE
AMERICAN WITH DISABILITIES ACT
ABOVE FINISH FLOOR
ABOVE FINISH GRADE
AMERICAN WIRE GAUGE
AMPERE
AMPERES INTERRUPTING CAPACITY (SYMMETRICAL)
AMP FRAME, AMP TRIP
AUTHORITY HAVING JURISDICTION
AMP SWITCH, AMP FUSE
AUTOMATIC TRANSFER SWITCH
AVERAGE
BDF
BR
BLDG
BUILDING DISTRIBUTION FRAME
BRANCH
BUILDING
CEC
CIRC., CKT.
CB
CSFD
C.
C.O.
CONN
CPT
CLCB
CLF
CT
CALIFORNIA ELECTRICAL CODE
CIRCUIT
CIRCUIT BREAKER
COMBINATION SMOKE FIRE DAMPER
CONDUIT
CONDUIT ONLY, COMPLETE WITH PULLSTRING
CONNECTED
CONTROL POWER TRANSFORMER
CURRENT LIMITING CIRCUIT BREAKER
CURRENT LIMITING FUSE
CURRENT TRANSFORMER
(D)
DIA
DISC
DIST
EXISTING TO BE DEMOLISHED
DIAMETER
DISCONNECT
DISTRIBUTION
E.C.
EMS
EMT
ENT
EWC
E.P.O.
E-O-L
EF
E/G
EP
(E)
(ER*)
ELECTRICAL CONTRACTOR
ENERGY MANAGEMENT CONTROL SYSTEM
ELECTRICAL METALLIC TUBING
ELECTRICAL NON-METALLIC TUBING
ELECTRIC WATER COLLER
EMERGENCY POWER OFF
END-OF-LINE CIRCUIT TERMINATOR
EXHAUST FAN
EQUIPMENT GROUND (GREEN)
EXPLOSION PROOF
EXISTING EQUIP TO REMAIN
EXISTING EQUIP TO BE RELOCATED (*CORRESPONDS TO
NEW LOCATION)
FT or '
FA
FLA
FEET
FIRE ALARM
FULL LOAD AMPS
GRD
GFCI
GFP
GEC
GROUND
GROUND FAULT CIRCUIT INTERRUPTER
GROUND FAULT PROTECTION
GROUNDING ELECTRODE CONDUCTOR
HACR
HOA
HVAC
H., W., D., L.
HID
HP
HPS
HEATING AIR CONDITIONING REFRIGERATION
HAND-OFF-AUTO
HEATING, VENTILATING AND AIR CONDITIONING
HEIGHT, WIDTH, DEPTH, LENGTH
HIGH INTENSITY DISCHARGE
HORSEPOWER
HIGH PRESSURE SODIUM
IN. or "
I/G
IDF
INCHES
OSOLATED GROUND
INTERMEDIATE DISTRIBUTION FRAME
JBOX JUNCTION BOX
K
KCMIL
KVA
KW
KWH
DEGREE KELVIN
THOUSAND CIRCULAR MILS
KILOVOLT AMPERES
KILOWATT
KILOWATT HOUR
LCL
L.F.
LTG, LTS
LPS
LONG CONTINUOUS LOAD
LINEAR FEET
LIGHTING
LOW PRESSURE SODIUM
MAX.
MDF
MOCP
MCB
MLO
M.C.
M
M/M
MV
MH
MIN.
MCA
MCC
MCM
MCP
MFR.
MTD
MW
MAXIMUM
MAIN DISTRIBUTION FRAME
MAXIMUM OVERCURRENT PROTECTION
MAIN CIRCUIT BREAKER
MAIN LUGS ONLY
MECHANICAL CONTRACTOR
METER
METER MAIN
MERCURY VAPOR
METAL HALIDE
MINIMUM
MINIMUM CIRCUIT AMPS
MOTOR CONTROL CENTER
THOUSAND CIRCULAR MILS
MOTOR CIRCUIT PROTECTOR
MANUFACTURER
MOUNTED
MICROWAVE
(N)
NATS
NEC
NEMA
NC
NO
NF
NIC
N.T.S.
NL
NO. or #
NEW
NON AUTOMATIC DISCONNECT
NATIONAL ELECTRICAL CODE
NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION
NORMALLY CLOSED
NORMALLY OPENED
NON-FUSED
NOT IN CONTRACT
NOT TO SCALE
NIGHT LIGHT
NUMBER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
%Z
PH. or ~
PC
P.C.
P
PVC
PDU
PRIMARY
PROVIDE
PT
PA
PERCENT IMPEDANCE
PHASE
PHOTOCELL
PLUMBING CONTRACTOR
POWER
POLY VINYL CHLORIDE
POWER DISTRIBUTION UNIT
OVER 600 VOLTS
FURNISH, INSTALL AND CONNECT
POTENTIAL TRANSFORMER
PUBLIC ADDRESS
RE
REC, RECEPT
REF
RGS
RMS
REPLACE EXISTING (IN-PLACE)
RECEPTACLE
REFRIGERATOR
RIGID GALVANIZED STEEL
ROOT MEAN SQUARE
SCC
SCS
SFD
SECONDARY
SMACNA
SPD
SQ
SHORT CIRCUIT CURRENT
STRUCTURED CABLING SYSTEM
SMOKE FIRE DAMPER
600 VOLTS AND LESS
SHEET MTL & AIR COND. CONTRACTORS' NATIONAL ASSOC.
SURGE PROTECTION DEVICE
SQUARE
TC
TEL/DATA
TV
T.V.S.S.
TYP
TIMECLOCK
TELEPHONE AND DATA
TELEVISION
TRANSIENT VOLTAGE SURGE SUPPRESSION
TYPICAL
U.G.P.S.
U.O.N.
U.P.S.
UNDERGROUND PULL SECTION
UNLESS OTHERWISE NOTED
UNINTERRUPTABLE POWER SYSTEM
VAV
V
VA
VD
VFD
VARIABLE AIR VOLUME
VOLTS
VOLT AMPERES
VOLTAGE DROP
VARIABLE FREQUENCY DRIVE
WP
W
WEATHERPROOF
WIRE
XFMR
XX
TRANSFORMER
EXISTING EQUIP TO BE DEMO'D
FLOOR BOX / SPECIALTY WALL BOX SYMBOLS
MECHANICAL EQUIPMENT CALLOUT, "AC" INDICATES UNIT TYPE AND "2" INDICATES UNIT NUMBER. REFER TO MECHANICAL DRAWINGS FOR EXACT LOCATION AND ELECTRICAL REQUIREMENTS.
ANNOTATIONS
TELEPHONE TERMINAL BACKBOARD SIZED AS NOTED, REFER TO
SYSTEM GROUND DETAIL.
BRANCH CIRCUIT SYMBOLS
1 3
E-1
XXX-X
XXXXXXXX
XXX
AC-2
A-1,3,5
X X
LV
P
12KV
SINGLE SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE SPECIFICATIONS FOR MORE INFORMATION.
TWO SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE SPECIFICATIONS FOR MORE INFORMATION.
THREE SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE SPECIFICATIONS FOR MORE INFORMATION.
FOUR SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE SPECIFICATIONS FOR MORE INFORMATION.
SIX SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN.
SEE SPECIFICATIONS FOR MORE INFORMATION.
DELTA CONFIGURATION
DETAIL CALLOUT, "3" INDICATES DETAIL NUMBER "E-1"
INDICATES SHEET NUMBER.
FEEDER SIZE DESIGNATION
LIGHTING FIXTURE DESIGNATION
KEYNOTE REFERENCE, REFER TO NOTES ON SHEETS, OR AS
DIRECTED
REVISION REFERENCE
WYE CONFIGURATION
GROUND
HOME RUN TO PANEL. LETTER DESIGNATES PANEL, NUMBERS
INDICATE CIRCUITS. PROVIDE DEDICATED NEUTRAL WIRE FOR
EACH 'HOT' CIRCUIT IN CONDUIT RUN, #12 AWG MINIMUM
UNLESS OTHERWISE NOTED.
CONCEALED CONDUIT OR BRANCH CIRCUIT UNLESS OTHERWISE
NOTED. 1/2" CONDUIT MINIMUM, (2) #12 AWG CONDUCTORS
MINIMUM.
CONCEALED CONDUIT OR BRANCH CIRCUIT ROUTED IN FLOOR
SLAB OR CONCRETE. COORDINATE INSTALLATION WITH GENERAL
CONTRACTOR AND SUPPORT AS REQUIRED. 1/2" CONDUIT (2) #12 AWG CONDUCTORS MINIMUM.
CONDUIT OR BRANCH CIRCUIT CONCEALED BELOW GRADE, 3/4"
CONDUIT MINIMUM WITH (2) 12 AWG CONDUCTORS MINIMUM AND A CODE SIZED EQUIPMENT GROUND.
SURFACE-MOUNTED CONDUIT OR BRANCH CIRCUIT UNLESS
OTHERWISE NOTED. 1/2" CONDUIT MINIMUM, (2) #12 AWG
CONDUCTORS MINIMUM. CONDUIT SHALL BE PAINT TO MATCH
ADJACENT SURFACE. COORDINATE COLOR WITH
ARCHITECT/INTERIORS.
CONDUIT STUB OUT, CAP, MARK AND RECORD ON AS-BUILT
DRAWINGS.
CONDUIT CONTINUATION.
FLEXIBLE CONNECTION AS REQUIRED. NUMBER OF CONDUCTORS
AS REQUIRED. VERIFY CONNECTION REQUIREMENTS WITH
MANUFACTURER PRIOR TO ROUGH-IN.
CONDUIT/ BRANCH CIRCUIT/FEEDER CONTINUATION DOWN
WALL TO FLOOR BELOW.
CONDUIT/ BRANCH CIRCUIT/FEEDER CONTINUATION UP WALL TO
FLOOR ABOVE.
EXISTING FEEDER, CONDUIT, WIRE TO BE DEMOLISHED.
LOW VOLTAGE DUCTBANK BELOW GRADE.
POWER DUCTBANK BELOW GRADE, SEE FEEDER TAG(s) FOR
QUANTITY AND SIZE OF CONDUIT AND WIRE.
MEDIUM -HIGH VOLTAGE DUCTBANK BELOW GRADE, WITH
VOLTAGE INDICATED. SEE FEEDER TAG(s) FOR QUANTITY AND SIZE OF CONDUIT AND WIRE.
FLUSH MOUNTED, LOCKABLE TERMINAL CABINET WITH TERMINAL
STRIPS AS REQUIRED.
SURFACE MOUNTED, LOCKABLE TERMINAL CABINET WITH
TERMINAL STRIPS AS REQUIRED.
DECORATIVE PENDANT
"EM" SHADED OR HALF-SHADED CONNECTION POINT INDICATES
FIXUTRE ON EMERGENCY POWER.
SURFACE MOUNTED EMERGENCY BATTERY PACK.
EXIT SIGN.
POLE MOUNTED LIGHT.
ABOVE-GRADE MOUNTED ADJUSTABLE ACCENT LIGHT.
BOLLARD LIGHT.
WALL STEP LIGHT.
RECESSED MULTI-LAMP ADJUSTABLE DOWNLIGHT.
CONCEALED LINEAR LIGHT STRIP.
SURFACE MOUNTED ADJUSTABLE LINEAR WALLWASHER.
TRACK LIGHT.
WALL MOUNTED FIXTURE.
SURFACE MOUNTED DOWNLIGHT.
RECESSED ADJUSTABLE ACCENT LIGHT.
RECESSED WALLWASHER.
RECESSED DOWNLIGHT.
RECESSED LINEAR WALLWASH.
PENDANT MOUNTED LINEAR.
RECESSED LINEAR OR PERIMETER WALLSLOT.
RECESSED ARCHITECTURAL TROFFER
SURFACE MOUNTED WRAPAROUND.
DECORATIVE SURFACE MOUNTED LIGHT.
STRIP LIGHT (B.O.H.)
RECESSED LENSED TROFFER
LIGHTING SYMBOLS
LIGHTING CONTROLS
KS
ab
ab
ab
WALL MOUNTED OCCUPANCY SENSOR. MOUNTING HEIGHT PER
ADA - UON OR REQUIRED. "xx" INDICATES THE FOLLOWING:
• IO: INFRARED OCCUPANCY SENSOR
• UO: ULTRASONIC OCCUPANCY SENSOR
• DO: DUAL TECHNOLOGY OCCUPANCY SENSOR.
• P: PHOTOCELL
• OP: COMBINATION PHOTOCELL AND DUAL TECHNOLOGY
OCCUPANCY SENSOR
LETTERS "ab" INDICATE ZONES CONTROLLED.
xx
MZ - #
G
SINGLE POLE SWITCH, MOUNTING HEIGHT PER ADA. SUBSCRIPT
"K" INDICATES KEY OPERATED SWITCH.
MANUAL ON/OFF, DIMMING AND GRAPHIC SCENE SELECT
CONTROL STATION.
LOW VOLTAGE MANUAL ON/OFF, DIMMING AND MULTI BUTTON
ZONE SELECT CONTROL STATION. "#" DENOTES NUMBER OF
ZONES. LETTERS "ab" INDICATE ZONES CONTROLLED.
WALL MOUNTED COMBINATION VACANCY SENSOR AND DIMMER
SWITCH, MOUNTING HEIGHT PER ADA - UON OR REQUIRED.
LETTERS "ab" INDICATES ZONES CONTROLLED. BOTH SWITCH
LEGS TO BE CONFIGURED IN A "MANUAL ON" CONFIGURATION.
CEILING MOUNTED SENSOR. PROVIDE WITH POWER PACK AND
RELAYS FOR PLUG LOAD AND HVAC CONTROL. LETTERS "ab"
INDICATE ZONES CONTROLLED. "xx" INDICATES THE FOLLOWING:
• OS: DUAL TECHNOLOGY OCCUPANCY SENSOR
• HOS: HIGH BAY/ HIGH CEILING OCCUPANCY SENSOR
• P: PHOTOCELL
• OP: COMBINATION PHOTOCELL AND DUAL TECHNOLOGY
OCCUPANCY SENSOR.
xx
ab
WALL MOUNTED COMBINATION OCCUPANCY SENSOR AND
DIMMER SWITCH, MOUNTING HEIGHT PER ADA - UON OR
REQUIRED. LETTERS "ab" INDICATE ZONES CONTROLLED.
o
v
MS - #
LOW VOLTAGE MANUAL ON/OFF, DIMMING AND MULTI BUTTON
SCENE SELECT CONTROL STATION. "#" DENOTES NUMBER OF
SCENE. LETTERS "ab" INDICATE ZONES CONTROLLED.
ab
ab
SZ LOW VOLTAGE MANUAL ON/OFF AND SINGLE ZONE
DIMMING CONTROL.
DUPLEX RECEPTACLE -MOUNTING HEIGHT PER ADA DETAIL
19/E7.01 OR AS NOTED. "C" INDICATES CONTROLLED RECEPTACLE, MUST BE WITHIN 6'-0" OF UNCONTROLLED RECEPTACLE PER TITLE 24 REQUIREMENTS.
DOUBLE DUPLEX RECEPTACLE, MOUNTING HEIGHT PER ADA
DETAIL 19/E7.01 OR AS NOTED.
DUPLEX, GFCI RECEPTACLE, MOUNTING HEIGHT PER ADA DETAIL 19/E7.01 OR AS NOTED. WP INDICATES WEATHERPROOF, REFER TO THE GENERAL PRODUCT SPECIFICATIONS.
DOUBLE DUPLEX, GFCI RECEPTACLE, MOUNTING HEIGHT PER ADA DETAIL 19/E7.01 OR AS NOTED. WP INDICATES WEATHERPROOF, REFER TO THE GENERAL PRODUCT SPECIFICATIONS.
DEDICATED 20A DUPLEX RECEPTACLE, MOUNTING HEIGHT PER
ADA DETAIL 19/E7.01 OR AS NOTED.
DUPLEX RECEPTACLE WITH USB CONNECTORS -MOUNTING
HEIGHT PER ADA DETAIL 19/E7.01 OR AS NOTED.
DOUBLE DUPLEX RECEPTACLE WITH USB CONNECTORS,
MOUNTING HEIGHT PER ADA DETAIL 19/E7.01 OR AS NOTED.
EMERGENCY DUPLEX RECEPTACLE -MOUNTING HEIGHT PER ADA
DETAIL 19/E7.01 OR AS NOTED.
NOTE: TICK MARKS SHOWN ON ANY DEVICE REPRESENTS
RECEPTACLE CONNECTED TO EMERGENCY CIRCUIT (RED DEVICE)
TYPICAL FOR ANY DEVICE IN LEGEND.
SIMPLEX RECEPTACLE, MOUNTING HEIGHT PER ADA DETAIL
19/E7.01 OR AS NOTED.
SPECIAL RECEPTACLE, MOUNTING HEIGHT PER ADA DETAIL
19/E7.01 OR AS NOTED. REFER TO PLAN NOTES.
DUPLEX RECEPTACLE FLUSH IN CEILING -MOUNT FLUSH IN FLOOR WHEN INDICATED IN A FLOOR BOX SYMBOL.
DOUBLE DUPLEX RECEPTACLE FLUSH IN CEILING -MOUNT FLUSH
IN FLOOR WHEN INDICATED IN A FLOOR BOX SYMBOL.
SIMPLEX RECEPTACLE FLUSH IN CEILING -MOUNT FLUSH IN FLOOR WHEN INDICATED IN A FLOOR BOX SYMBOL.
SPECIAL RECEPTACLE FLUSH IN CEILING -MOUNT FLUSH IN FLOOR WHEN INDICATED IN A FLOOR BOX SYMBOL.
DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER, MOUNTING
HEIGHT PER ADA DETAIL 19/E7.01 -UON OR REQUIRED.
DOUBLE DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER,
MOUNTING HEIGHT PER ADA DETAIL 19/E7.01 -UON OR REQUIRED.
DUPLEX, GFCI RECEPTACLE MOUNTED ABOVE COUNTER,
MOUNTING HEIGHT PER ADA DETAIL 19/E7.01 -UON OR REQUIRED.
WP INDICATES WEATHERPROOF, REFER TO THE GENERAL
PRODUCT SPECIFICATIONS.
DOUBLE DUPLEX, GFCI RECEPTACLE MOUNTED ABOVE COUNTER,
MOUNTING HEIGHT PER ADA DETAIL 19/E7.01 -UON OR REQUIRED.
WP INDICATES WEATHERPROOF, REFER TO THE GENERAL
PRODUCT SPECIFICATIONS.
SIMPLEX RECEPTACLE MOUNTED ABOVE COUNTER, MOUNTING
HEIGHT PER ADA DETAIL 19/E7.01 -UON OR REQUIRED.
SPECIAL RECEPTACLE MOUNTED ABOVE COUNTER, MOUNTING
HEIGHT PER ADA DETAIL 19/E7.01 -UON OR REQUIRED.
WALL MOUNTED JUNCTION BOX. MOUNTING HEIGHT AS NOTED.
4S/DP MINIMUM OR AS REQUIRED BY N.E.C..
JUNCTION BOX, MOUNTED IN ACCESSIBLE CEILING FOR
APPLICATION DENOTED ON PLAN. 4S/DP MINIMUM OR AS
REQUIRED BY N.E.C..
SURFACE MOUNTED MULTI-OUTLET ASSEMBLY. REFER TO
GENERAL PRODUCT SPECIFICATIONS. PROVIDE ALL COMPONENTS
NECESSARY FOR A COMPLETE INSTALLATION.
EXHAUST FAN, OR MOTOR LOAD. REFER TO MECHANICAL,
PLUMBING OR KITCHEN DRAWINGS FOR SPECIFIC LOAD
REQUIREMENTS OR AS NOTED.
FLUSH MOUNTED ELECTRICAL PANELBOARD OR LOAD CENTER.
REFER TO PANEL SCHEDULE.
SURFACE MOUNTED ELECTRICAL PANELBOARD OR LOAD CENTER.
REFER TO PANEL SCHEDULE.
DISTRIBUTION SWITCHBOARD. REFER TO SINGLE LINE DIAGRAM.
TRANSFORMER, REFER TO SINGLE LINE DIAGRAM.
FUSED DISCONNECT SWITCH, HP RATED, OR COMBINATION
MOTOR STARTER/DISCONNECT SWITCH WITH FUSES PER
EQUIPMENT MANUFACTURER AND WEATHERPROOF AS REQUIRED.
PROVIDE FINAL CONNECTION TO UNIT EQUIPMENT. SEE
MOTORIZED EQUIPMENT SCHEDULE FOR DISCONNECT AND
STARTER SIZES.
MOTOR STARTER COMBINATION SWITCH WITH HOA SELECTOR
SWITCH, ON "RUNNING LIGHT" RESET AND OVERLOAD
PROTECTION.
NON-FUSED DISCONNECT SWITCH, HP RATED AND
WEATHERPROOF AS REQUIRED. PROVIDE FINAL CONNECTION TO
UNIT EQUIPMENT. SEE MOTORIZED EQUIPMENT SCHEDULE FOR
DISCONNECT SIZES.
UTILITY COMPANY METER. PROVIDE "CT's" AND "PT's" AS
REQUIRED, REFER TO SINGLE LINE DIAGRAM.
CIRCUIT BREAKER, LINE 1 REPRESENTS FRAME SIZE/RATING; LINE 2 REPRESENTS TRIP SIZE/RATING; LINE 3 REPRESENTS NUMBER OF POLES AND LINE 4 REPRESENTS MISCELLANEOUS BREAKER
INFO. (SEE BELOW):
SHUNT = PROVIDE SHUNT TRIP MECHANISM.
HACR = PROVIDE HACR-RATED BREAKER.
GFP = GROUND FAULT PROTECTION
CLCB = CURRENT LIMITING CIRCUIT BREAKER
SS = PROVIDE SOLID STATE CIRCUIT BREAKER
FUSIBLE SWITCH: LINE 1 REPRESENTS SWITCH SIZE/RATING; LINE 2 REPRESENTS NUMBER OF POLES; LINE 3 REPRESENTS FUSE
SIZE/RATING; LINE 4 REPRESENTS FUSE TYPE; LINE 5 REPRESENTS MISCELLANEOUS FUSE INFO. (SEE BELOW):
SHUNT= PROVIDE SHUNT TRIP MECHANISM.
GFP = GROUND FAULT PROTECTION
CLF = CURRENT LIMITING FUSE
FUSIBLE SWITCH: LINE 1 REPRESENTS SWITCH SIZE/RATING; LINE 2 REPRESENTS NUMBER OF POLES; LINE 3 REPRESENTS FUSE
SIZE/RATING; LINE 4 REPRESENTS FUSE TYPE; LINE 5 REPRESENTS MISCELLANEOUS FUSE INFO. (SEE BELOW):
SHUNT= PROVIDE SHUNT TRIP MECHANISM.
GFP = GROUND FAULT PROTECTION
CLF = CURRENT LIMITING FUSE
GROUND CONNECTION, SIZE AS INDICATED OR AS REQUIRED.
LOW VOLTAGE TRANSFORMER
PULLBOX, SIZED PER N.E.C. OR AS NOTED.
RECESSED COMBINATION POWER OUTLET FOR IN FLOOR BOX
PER PLAN FOR FLEXIBLE CONNECTION TO FURNITURE SYSTEM.
VERIFY CONNECTION REQUIREMENTS WITH MANUFACTURER
PRIOR TO ROUGH-IN -MOUNT FLUSH IN FLOOR WHEN INDICATED
IN A FLOOR BOX SYMBOL.
POWER OUTLET OUTLET, MOUNTING HEIGHT PER ADA DEVICE
MOUNTING REQUIREMENTS. FOR FLEXIBLE CONNECTION TO
FURNITURE SYSTEM PROVIDE THE FOLLOWING:
• IN A NON-RATED INSULATED WALL, OR NON-RATED
UNINSULATED WALL, PROVIDE A 2-GANG MUD RING OR CADDY
#RBS SERIES BOX MOUNTING BRACKET (EQUAL BY B-LINE OR
RAYCO) WITH (2) 1-1/4"C.O. WITH PULL STRING TO ACCESSIBLE CEILING. PROVIDE 1-1/4" BUSHINGS AT CONDUIT ENDS. REFER
TO ARCHITECTURAL PLANS FOR WALL CONSTRUCTION/TYPE
AND CEILING CONDITIONS.
• IN A RATED WALL, PROVIDE (1) 4S/DP BOX WITH (2) 1-1/4"C.O.
AND (1) 4S/DP BOX WITH (1) 1-|"C.O. WITH PULL STRINGS IN EACH CONDUIT TO ACCESSIBLE CEILING. PROVIDE 1-1/4"
BUSHINGS AT CONDUIT ENDS. UTILIZE CADDY #RBS SERIES
BOX MOUNTING BRACKET TO MAINTAIN BOX ALIGNMENT.
(EQUAL BY B-LINE OR RAYCO)UTILIZE FIRESTOPPING SYSTEM
PADS RATED FOR USE ON THE INSIDE OR OUTSIDE OF THE
BOX (STI OR EQUAL) AS REQUIRED TO MAINTAIN RATING OF
WALL OR MEMBRANE. REFER TO ARCHITECTURAL PLANS FOR
WALL CONSTRUCTION/TYPE AND CEILING CONDITIONS.
GROUND BUS BAR
POWER SYMBOLS
J
J
3 T
F
M CT
1 150AF
150AT
3P
60AS
3P
50AF
CLASS J
T
PB POR
J
J
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ELECTRICAL LEAD
SHEET
E0.01
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
1. REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION & ELEVATION OF ALL LIGHTING FIXTURES AND ALL DEVICES. ALL WALL-MOUNTED DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO ROUGH-IN. IF ANY WALL MOUNTED
FIXTURES ARE PLACED WITHOUT VERIFICATION FROM THE ARCHITECT, CONTRACTOR SHALL RELOCATE FIXTURE TO APPROVED LOCATION AT NO ADDITIONAL COST.
2. VERIFY EXACT CEILING CONSTRUCTION WITH ARCHITECTURAL REFLECTED CEILING PLAN AND PROVIDE LIGHTING FIXTURES WITH ALL NECESSARY MOUNTING HARDWARE.
3. ALL RECESSED FIXTURES SHALL BE PROVIDED WITH ALL REQUIRED STRUCTURAL SUPPORTS AS REQUIRED BY THE CURRENTLY ADOPTED ISSUE OF THE UNIFORM BUILDING CODE, AS WELL AS ANY LOCAL CODES.
4. ALL COVE MOUNTED FIXTURES SHALL EXTEND THE FULL LENGTH OF THE COVE. CONTRACTOR TO FIELD MEASURE COVE LENGTH AND ORDER QUANTITY OF FIXTURES AS REQUIRED.
5. ALL DIMMING BRANCH CIRCUITS SHALL BE PROVIDED WITH A DEDICATED NEUTRAL CONDUCTOR FOR EACH ZONE/CHANNEL.
6. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR EXIT SIGN CHEVRONS AND NUMBER OF FACES PER EXIT SIGN.
ANY DISCREPANCIES BETWEEN EXIT SIGNS SHOWN ON THE ELECTRICAL AND ARCHITECTURAL PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO ORDERING EXIT SIGNS.
7. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR WILL NEED TO PROVIDE THE FOLLOWING ITEMS:
A. ALL BRANCH CIRCUITS SHALL BE IN EMT.
B. ALL BRANCH CIRCUITS SHALL BE ROUTED NEATLY TRAINED AND IN PARALLEL TO STRUCTURES OR DUCT WORK. THE TERM “TRAINED”MEANS ALL PARALLEL CONDUITS SHALL MAINTAIN THE SAME SPATIAL RELATIONSHIP WITH EACH OTHER FOR ENTIRE RUN TO INCLUDE RADIUS BENDS AND SWEEPS.
C. VISUALLY OBJECTIONABLE BRANCH CIRCUITS WILL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST.
D. SHOP DRAWINGS SHOWING LOCATION AND PLACEMENT OF ALL CONDUITS.
8. RECESSED FIXTURES LOCATED IN A FIRE-RATED CEILING OR WALL SHALL BE PROVIDED WITH A 5-SIDED RATED ENCLOSURE
SO CONSTRUCTED AS TO ALLOW CODE AND MANUFACTURER-REQUIRED CLEARANCES BETWEEN THE FIXTURE AND THE ENCLOSURE.
9. REFER TO GENERAL POWER PLAN NOTES AND COMMUNICATIONS PATHWAYS GENERAL NOTES FOR ADDITIONAL REQUIREMENTS WHEN POWER AND/OR DATA DEVICES ARE SHOWN ON THIS PLAN.
10. CONTRACTOR TO INCLUDE AN ALLOWANCE TO CORE AND SEAL PENETRATIONS THROUGH STRUCTURAL CONCRETE WALLS.
COORDINATE LOCATIONS AND REQUIREMENTS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS.
11. COORDINATE ALL PENETRATIONS WITH STRUCTURAL PLANS AND DETAILS.NO PENETRATIONS ARE PERMITTED UNLESS SPECIFICALLY NOTED ON STRUCTURAL DRAWINGS.
LIGHTING GENERAL NOTES
1. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET 24" MINIMUM.
2. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL.
3. COORDINATE ALL MOUNTING DIMENSIONS FOR ELECTRICAL DEVICES AND SWITCHES WITH ARCHITECTURAL INTERIOR ELEVATIONS PRIOR TO ROUGH-IN.
4. ALL FURNITURE FEED LOCATIONS TO BE VERIFIED WITH ARCHITECT AND FURNITURE VENDOR PRIOR TO ROUGH IN..
5. ALL FURNITURE WHIPS SHALL BE TRIMMED TO REDUCE EXCESS WHIP LENGTH
6. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR WILL NEED TO PROVIDE THE FOLLOWING ITEMS:
A. ALL BRANCH CIRCUITS SHALL BE IN EMT.
B. ALL BRANCH CIRCUITS SHALL BE ROUTED NEATLY AND IN PARALLEL TO STRUCTURES OR DUCT WORK.
C. VISUALLY OBJECTIONABLE BRANCH CIRCUITS WILL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST.
7. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC WHERE ADOPTED, ARTICLE 300.22(C.
8. PROVIDE G.F.C.I. TYPE RECEPTACLE(S) WITHIN 6 FEET OF ANY SINK.
9. CONTRACTOR TO INCLUDE AN ALLOWANCE TO CORE AND SEAL PENETRATIONS THROUGH STRUCTURAL CONCRETE WALLS.
COORDINATE LOCATIONS AND REQUIREMENTS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS.
10. COORDINATE ALL PENETRATIONS WITH STRUCTURAL PLANS AND DETAILS.NO PENETRATIONS ARE PERMITTED UNLESS SPECIFICALLY NOTED ON STRUCTURAL DRAWINGS.
POWER GENERAL NOTES
1. ELECTRICAL CONTRACTOR SHALL REFER TO MECHANICAL/PLUMBING AND ARCHITECTURAL DRAWINGS FOR EXACT LOCATIONS AND CHARACTERISTICS OF ALL EQUIPMENT LISTED IN SCHEDULE. ANY MODIFICATIONS AND/OR ADDITIONAL WORK NECESSARY SHALL BE INCLUDED IN THE BASE BID.
2. ELECTRICAL CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF ALL CONNECTION POINTS WITH THE EQUIPMENT INSTALLER PRIOR TO ROUGH-IN.
3. ELECTRICAL CONTRACTOR SHALL PROVIDE LOCAL REMOTE DISCONNECTING MEANS FOR ALL ELECTRIC HEATING EQUIPMENT IF REQUIRED BY THE LOCAL ELECTRICAL CODE.
4. ELECTRICAL CONTRACTOR SHALL COORDINATE THE ROUTING OF CONDUIT/WIRING TO ROOF-MOUNTED EQUIPMENT WITH EQUIPMENT INSTALLER PRIOR TO ROUGH-IN. WHERE ROOF-MOUNTED EQUIPMENT IS MANUFACTURED TO BE FED FROM
WITHIN MECHANICAL CURB ASSEMBLY -SEPARATE ROOF PENETRATIONS FOR WIRING CONNECTIONS SHALL NOT BE PERMITTED. ALL WIRING SHALL BE BELOW THE ROOF IN AN ACCESSIBLE CEILING SPACE LOCATION.
5. ALL ROOF MOUNTED EQUIPMENT SHALL BE NEMA 3R RATED
ROOF GENERAL NOTES
MEP COMPONENT ANCHORAGE NOTE
1. ALL MECHANICAL, PLUMBING, AND ELECTRICAL COMPONENTS SHALL BE ANCHORED AND INSTALLED PER THE DETAILS ON THE DSA APPROVED CONSTRUCTION DOCUMENTS. THE FOLLOWING COMPONENTS SHALL BE ANCHORED OR BRACED TO MEET THE FORCE AND DISPLACEMENT REQUIREMENTS PRESCRIBED IN THE 2019 CBC, SECTIONS 1617A.1.18 THROUGH 1617A.1.26 AND ASCE 7-16 CHAPTERS 13, 26 AND 30:
A. ALL PERMANENT EQUIPMENT AND COMPONENTS.
B. TEMPORARY, MOVEABLE OR MOBILE EQUIPMENT THAT IS PERMANENTLY ATTACHED (e.g. HARD WIRED) TO THE BUILDING UTILITY SERVICES SUCH AS ELECTRICITY, GAS OR WATER. "PERMANENTLY ATTACHED" SHALL INCLUDE ALL ELECTRICAL CONNECTIONS EXCEPT PLUGS FOR 110/220 VOLT RECEPTACLES HAVING A FLEXIBLE CABLE.
C. TEMPORARY, MOVABLE OR MOBILE EQUIPMENT WHICH IS HEAVIER THAN 400 POUNDS OR HAS A CENTER OF MASS LOCATED 4 FEET OR
MORE ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT IS REQUIRED TO BE RESTRAINED IN A MANNER APPROVED BY DSA.
2. THE FOLLOWING MECHANICAL AND ELECTRICAL COMPONENTS SHALL BE POSITIVELY ATTACHED TO THE STRUCTURE, BUT NEED NOT DEMONSTRATE DESIGN COMPLIANCE WITH THE REFERENCES NOTED ABOVE. THESE COMPONENTS SHALL HAVE FLEXIBLE CONNECTIONS PROVIDED BETWEEN THE COMPONENT AND ASSOCIATED DUCTWORK, PIPING, AND CONDUIT. FLEXIBLE CONNECTIONS MUST ALLOW MOVEMENT IN BOTH TRANSVERSE AND LONGITUDINAL DIRECTIONS:
A. COMPONENTS WEIGHING LESS THAN 400 POUNDS AND HAVE A CENTER MASS LOCATED 4 FEET OR LESS ABOVE THE ADJACENT FLOOR OR ROOF LEVEL THAT DIRECTLY SUPPORT THE COMPONENT.
B. COMPONENTS WEIGHING LESS THAN 20 POUNDS, OR IN THE CASE OF DISTRIBUTED SYSTEMS, LESS THAN 5 POUNDS PER FOOT, WHICH ARE SUSPENDED FROM A ROOF OR FLOOR OR HUNG FROM A WALL.
3. THE ANCHORAGE OF ALL MECHANICAL, ELECTRICAL AND PLUMBING COMPONENTS SHALL BE SUBJECT TO THE APPROVAL OF THE DESIGN PROFESSIONAL IN GENERAL RESPONSIBLE CHARGE OR STRUCTURAL ENGINEER DELEGATED RESPONSIBILITY AND ACCEPTANCE BY DSA.
THE PROJECT INSPECTOR WILL VERIFY THAT ALL COMPONENTS AND EQUIPMENT HAVE BEEN ANCHORED IN ACCORDANCE WITH ABOVE REQUIREMENTS.
MECHANICAL PIPING (MP), MECHANICAL DUCTS (MD), PLUMBING PIPING (PP), ELECTRICAL DISTRIBUTION SYSTEMS (E):
MP MD PP E OPTION 1: DETAILED ON THE APPROVED
DRAWINGS WITH PROJECT SPECIFIC NOTES
AND DETAILS.
MP MD PP E OPTION 2: SHALL COMPLY WITH THE
APPLICABLE PRE-APPROVAL (OPM#): MASON
WEST 0043-13 OR MW SAUSSE 0203-13
PIPING DUCTWORK AND ELECTRICAL DISTRIBUTION SYSTEM BRACING NOTE
PIPING, DUCTWORK, AND ELECTRICAL DISTRIBUTION SYSTEMS SHALL BE BRACED TO COMPLY WITH THE FORCES AND DISPLACEMENTS PRESCRIBED IN ASCE 7-16 SECTION 13.3 AS DEFINED IN ASCE 7-16 SECTIONS 13.6.5, 13.6.6, 13.6.7, 13.6.8; AND 2019 CBC, SECTIONS 1617A.1.24, 1617A.1.25 AND 1617A.1.26.
THE METHOD OF SHOWING BRACING AND ATTACHMENTS TO THE STRUCTURE FOR THE IDENTIFIED DISTRIBUTION SYSTEM ARE AS NOTED BELOW. WHEN BRACING AND ATTACHMENTS ARE BASED ON A PREAPPROVED INSTALLATION GUIDE (e.g. OSHPD OPM FOR 2013 CBC OR LATER),
COPIES OF THE BRACING SYSTEM INSTALLATION GUIDE OR MANUAL SHALL BE AVAILABLE ON THE JOBSITE PRIOR TO THE START OF AND DURING THE HANGING AND BRACING OF THE DISTRIBUTION SYSTEMS. THE STRUCTURAL ENGINEER OF RECORD SHALL VERIFY THE ADEQUACY OF THE STRUCTURE TO SUPPORT THE HANGER AND BRACE LOADS.
MEP SYSTEMS COMPONENT ANCHORAGE AND BRACING NOTES
THESE NOTES ESTABLISH MINIMUM QUALITY LEVELS AND COORDINATION REQUIREMENTS. RESPECTIVE UTILITY COMPANY PLANS AND
REQUIREMENTS TAKE PRECEDENCE OVER THESE NOTES WITH REGARD TO RESPECTIVE UTILITY COMPANY CONDUIT AND UNDERGROUND STRUCTURE SYSTEMS.
1. CALL UNDERGROUND SERVICE ALERT (USA) AT 1 (800) 422-4133 OR APPLICABLE STATE AND LOCAL DIG SAFE OR UNDERGROUND ALERT HOTLINES PRIOR TO CONSTRUCTION START.
2. COORDINATE ALL UNDERGROUND STRUCTURES AND CONDUIT ROUTING WITH LANDSCAPE ARCHITECT PRIOR TO ROUGH-IN TO ENSURE THAT SUCH ITEMS ARE NOT PLACED IN CRITICAL LANDSCAPE PLANTING/HARDSCAPE AREAS.
3. VAULTS, MAINTENANCE HOLES (MH's) AND CONDUITS SHALL MAINTAIN A MINIMUM COVER OF 24" BELOW FINAL SURFACE AT ALL CONDITIONS. INCLUDE ALL COSTS IN BASE BID TO MEET UTILITY COMPANY REQUIREMENTS WHICH MAY REQUIRE GREATER MINIMUM CONDUIT DEPTHS.
4. VAULTS, MH's AND PULLBOXES (PB's) SHALL BE EQUIPPED WITH KNOCKOUT PANELS OR PRE-CAST INDIVIDUAL CONDUIT OPENINGS.
CONDUITS SHALL ONLY ENTER AND EXIT ON END/SHORT WALLS. CONDUITS MAY NOT ENTER AND EXIT ON SIDE/LONG WALLS, CEILINGS OR FLOORS UNLESS OTHERWISE NOTED.
5. CUT DUCTS FLUSH WITH INTERIOR VAULT/MH/PB WALL.
6. GROUT AROUND DUCT ENTRANCES ON VAULT/MH/PB WALLS.
7. SLURRY BACKFILL AROUND DUCTS WITHIN 5 FEET OF VAULT/MH/PB TO PREVENT SHEARING.
8. CONDUITS PASSING UNDER THE BUILDING PERIMETER SHALL BE ENCASED IN LIGHTWEIGHT CONCRETE OR WATER-IMPERVIOUS CLAY TO PREVENT WATER INFILTRATION. SEE ELECTRICAL SPECIFICATIONS FOR ADDITIONAL INFORMATION.
9. CONDUIT BEND RADIUS FOR BUILDING ENTRANCES AND AT POLES SHALL BE A MINIMUM OF 24" FOR CONDUITS WITH LESS THAN 2" INTERNAL DIAMETER AND A MINIMUM OF 48" FOR CONDUITS WITH MORE THAN 2" INTERNAL DIAMETER.
10. PREFERRED CONDUIT SWEEP RADIUS BETWEEN VAULTS IS 25 FEET. UNDER NO CIRCUMSTANCES SHALL THE CONDUIT SWEEP RADIUS BE LESS THAN 12.5 FEET. MAXIMUM OF 90 DEGREES PER SWEEP AND LIMITED TO NO MORE THAN (2) 90 DEGREE WEEPS BETWEEN VAULTS.
11. VAULTS/MH's/PB's ARE TO BE EQUIPPED WITH RACKING, GROUNDING LUGS, AND BOLT-DOWN LIDS UNLESS OTHERWISE NOTED.
12. VAULTS AND MH's TO BE EQUIPPED WITH ROUND COVERS, EXTENSION RINGS AS REQUIRED, LADDERS AND (3) SEGMENTS OF 6 FOOT HIGH CABLE RACKING PER EACH LONG WALL.
13. LABEL ALL NON-UTILITY COMMUNICATION VAULT/MH/PB COVERS WITH "COMMUNICATIONS" UNLESS OTHERWISE NOTED ON PLANS.
14. COORDINATE FINAL VAULT/MH/PB OPENING HEIGHT WITH G.C. PRIOR TO ROUGH-IN TO ENSURE FINAL GRADE DOES NOT SLOPE INTO VAULT/MH/PB OPENING.
15. CONTRACTOR TO PROVIDE A MINIMUM OF 8" DEEP COMPACTED 1/2" DIAMETER GRAVEL, UNDER ALL VAULTS, MH's OR PB's TO ENSURE UNIFORM DISTRIBUTION OF SOIL PRESSURE ON THE FLOOR AND BE ABLE TO DISSIPATE WATER OUT OF THE VAULT, MH OR PB.
16. ALL VAULTS/MH's/PB's WITHOUT GROUNDING LUGS SHALL HAVE AN 8' x 3/4" COPPER GROUND ROD DRIVEN THRU THE FLOOR TO ALLOW GROUNDING OF ITEMS WITHIN.
17. ALL VAULTS/MH's/PB's SHALL BE PROVIDED WITH TRAFFIC RATED COVERS WHEN LOCATED IN PAVED AREAS UTILIZED FOR VEHICLE TRAFFIC.
18. IF THE WATER OR MOISTURE BARRIER ON OR NEAR THE FOUNDATION OF A BUILDING IS DISTURBED IN ANY MANNER BY EXCAVATION OR OTHER CONSTRUCTION WORK. THE MOISTURE BARRIER MUST BE REPAIRED FOLLOWING THE RECOMMENDATIONS OF THE MANUFACTURER OF THE ORIGINAL BARRIER PRODUCT.
19. THE CONTRACTOR SHALL INCLUDE IN BASE BID ALL COSTS TO COMPLY WITH ALL REQUIREMENTS FOR CONFINED SPACE ENTRY PER THE OSHA REQUIREMENTS 29 CFR-1910.146, 29 CFR-1910.268, ETC. DURING ANY CONFINED SPACE ENTRY.
20. ANY DUCTS LEAVING A VAULT, MH OR PB ROUTED INTO A FACILITY SHALL BE PLUGGED AT EACH END USING REMOVEABLE MECHANICAL PLUGS DESIGNED TO PREVENT WATER AND GAS FROM ENTERING THE FACILITY.
21. SEE ELECTRICAL SPECIFICATIONS AND PLAN DETAILS FOR ADDITIONAL REQUIREMENTS REGARDING UNDERGROUND CONDUITS AND IN- GRADE VAULT/MH/PB/JUNCTION BOXES.
22. INSTALL MULE TAPE OR 3/8" PULL ROPE AND TRUE-TAPE IN EACH UTILITY CONDUIT.
SITE UTILITY PLAN GENERAL NOTES
1. THE ELECTRICAL DRAWINGS ARE DIAGRAMMATIC ONLY. DO NOT SCALE THE ELECTRICAL DRAWINGS TO DETERMINE THE LOCATION OF EQUIPMENT OR OUTLETS. SEE ARCHITECTURAL PLANS, WHERE PROVIDED ON PROJECT, FOR EXTENT OF DEMOLITION.
2. THE EXISTING CONDITIONS SHOWN ARE FROM AVAILABLE RECORD DRAWINGS AND SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL VERIFY ACTUAL EXISTING CONDITIONS AT SITE PRIOR TO SUBMITTING BID. ALL DEMOLITION, ALTERATION, EXTENSION, RELOCATION, REHABILITATION WORK SHALL BE INCLUDED IN CONTRACT. NO ADDITIONAL ALLOWANCE OR CHANGE ORDERS WILL BE ACCEPTED.
3. CONTRACTOR IS RESPONSIBLE TO RELOCATE OR REMOVE FROM WALLS, CEILINGS, FLOOR SPACES, ETC. ANY EXISTING CONDUITS, WIRES, BOXES, FITTINGS, FIXTURES OR OTHER ELECTRICAL EQUIPMENT WHICH INTERFERES WITH PLANNED REMODEL WORK. PROVIDE CIRCUIT CONTINUATION REQUIRED FOR ALL EXISTING OUTLETS, FIXTURES, EQUIPMENT, ETC. SCHEDULED TO REMAIN.
4. NOTIFY THE ENGINEER IMMEDIATELY WHEREVER EXISTING EQUIPMENT IS ENCOUNTERED WHICH MUST BE RELOCATED DUE TO THE NEW CONSTRUCTION, OR NOT INDICATED ON "AS-BUILT" DRAWINGS OR WAS BURIED UNDERGROUND OR EMBEDDED IN STRUCTURE WALLS.
5. CAREFULLY PROTECT ALL WALLS, TRIM, FLOORS, EQUIPMENT, UTILITY LINES AND MATERIALS. WHEN WORKING ON FINISHED SURFACES,
LIMIT DAMAGE TO THE SMALLER AREA IF POSSIBLE AND RESTORE TO THE ORIGINAL CONDITION ALL SURFACES WHICH ARE DAMAGED BECAUSE OF THE INSTALLATION OF THIS WORK.
6. EQUIPMENT, MATERIALS AND SUPPLIES TEMPORARILY REMOVED FOR PROTECTION SHALL BE REPLACED IN ORIGINAL LOCATIONS. ANY MATERIALS DAMAGED SHALL BE REPLACED WITH NEW MATERIALS OF LIKE KIND AND QUALITY.
7. DEMOLITION WORK SHALL BE DONE IN A MANNER WHICH WILL NOT CAUSE UNNECESSARY INCONVENIENCE OR DANGER TO USERS OF THE PREMISES AND ADJACENT SITE, AND NOT INTERFERE WITH ITS OPERATION. ANY DEMOLITION WORK TO BE PERFORMED MUST BE PLANNED IN ADVANCE.
8. DO ALL DRILLING, CUTTING, ETC. REQUIRED TO DEMOLISH ELECTRICAL WORK AS INDICATED OR PROVIDE BLANK COVER PLATE ON ALL OUTLETS EXPOSED BY REMOVAL OF FIXTURE OF DEVICES.
9. RESEAL ALL PENETRATIONS OR OPENING THROUGH WALLS, CEILING, FLOORS, ETC., TO MAINTAIN THE RATING OF STRUCTURE.
10. CONTRACTOR SHALL VERIFY EXISTING CONDUIT/CONDUCTOR RUNS ON CIVIL DEMOLITION PLAN, SHEET C1.01. REUSE AS REQUIRED AND REMOVE ALL UNUSED CONDUIT/CONDUCTORS. REMOVE CONDUIT BACK TO SCOPE OF WORK LIMIT LINE. AT EACH END OF FEEDER, TAG AND LABEL CONDUIT. DOCUMENT DETAILED DIMENSIONS ON AS-BUILTS. REMOVE CONDUCTORS BACK TO SOURCE (VERIFY WITH OWNER).
UNUSED CONDUIT IN INACCESSIBLE LOCATIONS (WALLS TO REMAIN) CAN BE ABANDONED IN PLACE.
11. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDUIT/WIRING RUNS, REUSE AS REQUIRE AND REMOVED ALL UNUSED CONDUIT/WIRING.
UNUSED CONDUIT IN INACCESSIBLE LOCATIONS (WALLS TO REMAIN) CAN BE ABANDONED IN PLACE. REMOVE UNUSED WIRING.
12. CONTRACTOR TO VERIFY CIRCUIT NUMBER AND LOADS FOR ALL EXISTING EQUIPMENT PRIOR TO INSTALLATION OF NEW OR RELOCATED ELECTRICAL EQUIPMENT. REASSIGN CIRCUITS AND LOADS ACCORDINGLY. PROVIDE COMPLETE "AS BUILT" DRAWINGS AND TYPEWRITTEN DIRECTORIES FOR PANELS.
13. WHERE NECESSARY TO SHUT OFF UTILITY SERVICES OR CAUSE INTERRUPTION TO POWER OR SIGNAL SYSTEMS WHILE A BUILDING IS
OCCUPIED OR THAT EFFECT ADJACENT BUILDINGS, SCHEDULE OUTAGES OR INTERRUPTIONS WITH THE OWNER, BUILDING OCCUPANTS AND/OR ADJACENT BUILDING OWNER(S) AND OCCUPANTS PRIOR TO CONDUCTING OUTAGE(S) OR INTERRUPTIONS.
DEMOLITION NOTES
1. THE ELECTRICAL CONTRACTOR (EC) SHALL INCLUDE AND PROVIDE IN BID ALL LABOR AND MATERIALS NECESSARY FOR A COMPLETE AND OPERATIONAL INSTALLATION OF ALL ELECTRICAL SYSTEMS.
2. EC SHALL COORDINATE AND OBTAIN ALL APPROVALS, PERMITS, AND DOCUMENTS FROM REGULATORY AGENCIES AND UTILITY COMPANIES.
3. ALL CONDUIT RACEWAY SYSTEMS ARE TO BE INSTALLED AS FOLLOWS:
A. RIGID GALVANIZED STEEL IS TO BE INSTALLED IN ALL AREAS WHICH ARE EXPOSED TO WEATHER AND/OR PHYSICAL DAMAGE.
B. FLEXIBLE METALLIC CONDUIT I S PERMITTED FOR SHORT CONNECTIONS TO LIGHT FIXTURES (6'-0" MAX).
C. FLEXIBLE CONDUIT SHALL ALSO BE INSTALLED FOR EQUIPMENT REQUIRING VIBRATION ISOLATION AND HORIZONTAL RUNS IN WOODEN STUD WALLS. ELECTRICAL METALLIC TUBING (EMT) WITH COMPRESSION TYPE FITTINGS SHALL BE USED FOR BUILDING INTERIOR WORK.
D. PVC CONDUIT SHALL BE USED FOR UNDERGROUND CONDUITS. ROUTE CODE SIZED GROUND WIRE INSIDE OF CONDUIT. CONDUIT RISERS AND STUBS ABOVE GRADE SHALL BE I.M.C. WITH HALF-LAPPED TAPE COVERING OR PVC COATING AND UTILITY COMPANIES.
4. UNLESS OTHERWISE NOTED OR REFERENCED ON THE DRAWINGS ALL NEW ELECTRICAL WIRING IS TO BE 600V RATED COPPER WITH TYPE "THHN/THWN" INSULATION.
5. ALL MOUNTING HEIGHTS REFERENCED ON DRAWINGS ARE MEASURED FROM FINISHED FLOOR UNLESS OTHERWISE REFERENCED OR INDICATED ON THE DRAWINGS.
6. ALL ELECTRICAL EQUIPMENT LOCATIONS (LIGHTING, RECEPTACLE, FLOOR BOX, ETC.) ARE TO BE VERIFIED WITH THE ARCHITECT AND/OR EQUIPMENT SUPPLIER PRIOR TO BEGINNING ANY ROUGH-IN.
7. ALL LIGHTING FIXTURES SHALL BE MOUNTED AND SUPPORTED IN ACCORDANCE WITH OSHA STANDARDS, AND ALL STATE, LOCAL, SEISMIC, AND CALIFORNIA ELECTRIC CODES.
8. THE DRAWINGS INCLUDED IN THIS DOCUMENT SET ARE DIAGRAMMATIC. THEY ARE REPRESENTATIVE OF THE ENGINEER OF RECORDS DESIGN INTENT FOR ALL ELECTRICAL DEVICES/EQUIPMENT AND THE INDIVIDUAL POWER FEEDS THEY ARE TO BE CONNECTED TO. THE SELECTED EC SHALL BE RESPONSIBLE FOR PROVIDING ALL J-BOXES, CONDUIT, WIRING/CABLING, ETC. AS REQUIRED FOR A COMPLETE AND OPERATIONAL ELECTRICAL INSTALLATION.
9. ALL ELECTRICAL EQUIPMENT (PANELS, RECEPTACLES, J-BOXES, ETC.) SHALL BE WEATHERPROOF AND/OR INSTALLED IN A NEMA 3R ENCLOSURE WHERE APPLICABLE OR INSTALLED OUTDOORS.
10. ALL ELECTRICAL WORK SHALL BE PERFORMED ACCORDING TO STATE, LOCAL, NATIONAL, AND DISTRICT STANDARDS AND CODES.
COORDINATE SPECIFIC REQUIREMENTS WITH DISTRICT STANDARDS AND AUTHORITY HAVING JURISDICTION.
11. ALL ELECTRICAL EQUIPMENT SHALL BE NEW AND IS TO BE CLEARLY LABELED/IDENTIFIED AS UNDERWRITER LABORATORIES (UL) COMPLIANT UNLESS OTHERWISE NOTED OR REFERENCED IN THE DRAWINGS OR SPECIFICATIONS.
12. EC IS RESPONSIBLE FOR SECURING ALL REQUIRED BUILDING PERMITS AND SHALL INCLUDE THE COST TO SECURE BUILDING PERMITS IN THEIR FINAL BID.
13. UNLESS OTHERWISE WRITTEN, STATED, OR REFERENCED IN DRAWINGS OR SPECIFICATIONS CONTRACTOR SHALL GUARANTEE THE COMPLETE ELECTRICAL INSTALLATION FOR A PERIOD OF 1-YEAR.
14. ALL ELECTRICAL DISTRIBUTION EQUIPMENT (PANELS, DISTRIBUTION BOARDS, TRANSFORMERS, ETC), FEEDERS (CONDUIT, CONDUCTOR SIZE, AND QUANTITY), MECHANICAL EQUIPMENT, ELEVATORS, VARIABLE FREQUENCY DRIVES (VFD'S), ETC. MAY ONLY BE REFERENCED ON THE SINGLE-LINE DRAWING AND NOT INDIVIDUAL PLAN SHEETS. EC SHALL REVIEW AND VERIFY ALL REFERENCED INFORMATION ON THE SINGLE-LINE DRAWING.
15. EC SHALL BE RESPONSIBLE FOR ALL REQUIRED SAW-CUTTING, CORE DRILLING, PATCHING, REFINISHING, ETC. AS REQUIRED FOR INSTALLATION OF ELECTRICAL EQUIPMENT AND SYSTEMS. ANY PENETRATIONS OR OPENINGS MADE IN WALLS OR STRUCTURES SHALL BE PATCHED AND/OR SEALED AS REQUIRED TO MAINTAIN THE INTEGRITY AND/OR RATING OF THE WALL OR STRUCTURE.
16. EC SHALL VISIT THE SITE PRIOR TO SUBMISSION OF THEIR FINAL BID TO VERIFY ALL EXISTING SITE CONDITIONS WHICH MAY AFFECT THE COMPLETION OF THE ELECTRICAL INSTALLATION. ALL METHODS AND REQUIREMENTS FOR INSTALLATION SHALL BE DETERMINED PRIOR TO BID DATE. ELECTRICAL EC SHALL NOTIFY THE ENGINEER OF RECORD OF ANY REQUIRED MODIFICATIONS WHICH ARE NOT REFERENCED ON THESE ELECTRICAL PLANS. SUBMITTAL OF THE EC'S BID DEMONSTRATES THE CONTRACTOR'S AWARENESS OF ALL SITE CONDITIONS AND REQUIRED WORK TO BE PERFORMED.
17. ALL CEILINGS AND CEILING SYSTEMS AS A RULE ARE CONSIDERED TO BE INACCESSIBLE. ALL ELECTRICAL DEVICES AND EQUIPMENT INSTALLED ABOVE CEILINGS ARE TO BE MOUNTED IN A LOCATION WHICH IS ACCESSIBLE. IN SITUATIONS WHERE ELECTRICAL DEVICES AND
EQUIPMENT MUST BE INSTALLED IN AN AREA WHICH IS INACCESSIBLE, EC SHALL INSTALL AN ADEQUATELY SIZED, CODE COMPLIANT
ACCESS PANEL AS REQUIRED BY CURRENT CODES -LOCATION OF THE REQUIRED ACCESS PANEL SHALL BE COORDINATE WITH THE ARCHITECT AND INTERIOR DESIGNER PRIOR TO ROUGH-IN.
18. EC IS RESPONSIBLE FOR COMPLETING ALL FINAL ELECTRICAL CONNECTIONS TO OWNER FURNISHED EQUIPMENT AND SHALL PROVIDE ALL MOTOR START SWITCHES, DISCONNECTS, ETC. AS REQUIRED.
19. ALL ELECTRICAL EQUIPMENT CONNECTIONS, MOUNTING LOCATIONS, ELECTRICAL REQUIREMENTS, ETC. ARE TO BE COORDINATED AND VERIFIED PRIOR TO COMMENCEMENT OF ELECTRICAL ROUGH-IN.
20. EC TO SUBMIT SHOP DRAWINGS FOR THE APPROVAL OF THE ELECTRICAL ENGINEER OF RECORD FOR ALL ELECTRICAL EQUIPMENT AND MATERIALS TO BE UTILIZED IN THE ELECTRICAL INSTALLATION. ALL APPROVALS BY THE ENGINEER OF RECORD MUST BE SECURED PRIOR TO COMPLETION OF ANY PURCHASE ORDERS OR ROUGH-IN WORK.
21. THESE ELECTRICAL DRAWINGS AND ASSOCIATED SPECIFICATIONS ARE TO BE CONSIDERED CONTRACT DOCUMENTS FOR AGENCY REVIEW/APPROVAL AND EC BIDDING PURPOSES.
22. THE COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH CEC ARTICLE 250. ALL POWER AND LIGHTING CIRCUITS SHALL BE INSTALLED WITH A MINIMUM #12AWG CU GROUND WIRE UNLESS OTHERWISE NOTED OR REFERENCED.
23. EC TO PROVIDE ENGRAVED PHENOLIC NAMEPLATES ON ALL DISCONNECT SWITCHES, DISTRIBUTION EQUIPMENT, J-BOXES ETC. WITH METALLIC COVERS. SEE GENERAL NOTES ON SINGLE-LINE DIAGRAM FOR SPECIFIC INFORMATION REGARDING NAMEPLATE REQUIREMENTS.
24. ELECTRICAL AND LIGHTING COVER PLATE COLOR, ENGRAVING AND LABELING PER SPECIFICATIONS.
25. AT THE COMPLETION OF THE PROJECT THE EC SHALL PROVIDE THE OWNER WITH A COMPLETE SET OF AS-BUILT ELECTRICAL DRAWINGS.
26. ANY AND ALL WORK THAT REQUIRES AN INTERRUPTION TO A BUILDING(S) ELECTRICAL SERVICE MUST BE COORDINATED WITH THE DISTRICT A MINIMUM OF 48 HOURS IN ADVANCE. ANY SERVICE DOWNTOWN SHALL NOT OCCUR DURING SCHOOL HOURS.
27. EC SHALL BE RESPONSIBLE FOR FOR ENSURING THAT ALL LOW VOLTAGE SYSTEMS ARE COMPATIBLE AND ARE COMPLETE AND OPERATIONAL.
28. EC SHALL PERMANENTLY TAG ALL CONDUCTORS IN EACH ELECTRICAL AND LOW VOLTAGE SYSTEM AS REFERENCED IN THE SPECIFICATIONS.
29. ANY SURFACE MOUNTED EXPOSED CONDUIT IN VIEW OF THE PUBLIC SHALL BE PAINTED TO MATCH THE FINISH OF THE SURFACE TO WHICH IT IS MOUNTED WITH TWO (2) COATS OF PAINT. ALL EXTERIOR SURFACE MOUNTED EXPOSED CONDUITS ARE TO BE PAINTED WITH TWO (2) COATS OF WEATHERPROOF LATEX PAINT.
30. EC TO PROVIDE ALL CONDUIT ONLY (C.O.) INFRASTRUCTURE WITH A 3/16" NYLON PULL ROPE. LABEL PULL ROPE AT EACH END WITH THE LOCATIONS OF ORIGIN AND TERMINATION.
31. IN INSTANCES WHERE A CONFLICT BETWEEN THE ELECTRICAL DRAWINGS AND THE SPECIFICATIONS FOR THE PROJECT EXISTS, THE EC SHALL ADHERE TO THE MORE STRINGENT REQUIREMENT.
32. ELECTRICAL DRAWINGS ARE DIAGRAMMATIC. AS SUCH, ALL ELECTRICAL EQUIPMENT LOCATIONS, CONDUIT ROUTING, ETC. ARE NOT PRECISE AND SHALL BE COORDINATED, VERIFIED, AND DETERMINED IN THE FIELD. EC TO INSTALL ALL ELECTRICAL EQUIPMENT AND
ROUTE ALL CONDUITS IN LOCATIONS WHICH MEET CODE REQUIREMENTS FOR ACCESSIBILITY/MOUNTING AND DO NOT INTERFERE WITH ANY BUILDING STRUCTURES, UTILITIES, OR OTHER TRADE EQUIPMENT.
33. ALL EXISTING SITE RELATED ELECTRICAL EQUIPMENT (I.E. UNDERGROUND UTILITIES, DUCTS, STRUCTURES, PULL BOXES, ETC.) LOCATIONS ARE DIAGRAMMATIC IN NATURE AND ONLY REFLECT APPROXIMATE LOCATIONS, QUANTITIES, AND/OR ROUTING INFORMATION. ALL
REFERENCED INFORMATION HAS EITHER BEEN SURVEYED, REPORTED BY THE OWNER/OWNERS REP, AND/OR REFERENCED ON AN AS- BUILT RECORD DOCUMENTS. ALL EXISTING ELECTRICAL EQUIPMENT REFERENCE D ON THESE DRAWINGS IS TO BE FIELD VERIFIED BY THE
CONTRACTOR PRIOR TO COMMENCEMENT OF BY ACCEPTING THESE PLANS OR PROCEEDING WITH ELECTRICAL SCOPE OF WORK,
AGREES TO ACCEPT LIABILITY AND SHALL RENDER THE ENGINEER OF RECORD HARMLESS FOR ANY ELECTRICAL EQUIPMENT NOT REPORTED TO THE ENGINEER DURING THE DESIGN PROCESS. THE CONTRACT TO TAKE THE REQUIRED PRECAUTIONARY MEASURES TO ENSURE ALL EXISTING ELECTRICAL EQUIPMENT IS PROTECTED IN PLACE.
34. ANY EXISTING BUILDING STRUCTURES OR SURFACES DAMAGED BY DEMOLITION OR DURING INSTALLATION ACTIVITIES SHALL BE REPAIRED, PATCHED, AND/OR REFINISHED TO THE SATISFACTION OF THE OWNER.
35. ALL EXISTING ELECTRICAL EQUIPMENT INDICATED TO BE DEMOLISHED SHALL BE REMOVED ENTIRELY AND ALL AFFECTED SURFACES OR STRUCTURES SHALL BE REPAIRED, REPLACED, AND/OR REFINISHED TO MATCH THE ADJACENT SURFACES OR DAMAGED ITEM(S).
36. FOR CLARITY ONLY RECONSTRUCTION OR NEW WORK RELATED ELEMENTS AND SELECT EXISTING FACILITIES SPECIFICALLY REQUIRING COORDINATION WITH ANY NEW WORK.
37. ALL CONDUITS, BOXES, SURFACE MOUNTED RACEWAYS, SUPPORT DEVICES, AND ASSOCIATED FITTINGS SHALL BE MOUNTED IN CONCEALED LOCATIONS ABOVE CEILINGS, DUCTS, TRUSSES, BEAMS, ETC. IN AREAS WHERE A CONCEALED MOUNTING LOCATION IS NOT AVAILABLE EQUIPMENT SHALL BE PAINTED TO MATCH THE ADJACENT SURFACES.
38. ANY PENETRATIONS BY CONDUITS OR OTHER ELECTRICAL EQUIPMENT THROUGH A FIRE RATED WALL -WHETHER EXISTING OR NEW -
SHALL MAINTAIN THE APPROPRIATE FIRE RATING BY SEALING THE PENETRATION WITH THE APPROPRIATE UL-LISTED FIRE-STOP MATERIAL/SYSTEM.
39. ELECTRICAL CONTRACTOR SHALL PREPARE AND SUBMIT THE FOLLOWING CALIFORNIA ENERGY COMMISSION T-24 CERTIFICATE OF ACCEPTANCE LTG-1-1, PARTS 1, 2, & 3; LIGHTING CONTROL LTG-2-A; AND/OR AUTOMATIC DAYLIGHTING CONTROL LTG-3-A, AS THEY APPLY TO THE BUILDING DEPARTMENT PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.
40. LEED COMMISSIONING NOTE:ELECTRICAL CONTRACTOR TO COORDINATE AND PROVIDE ASSISTANCE FOR COMPLETE COMMISSIONING OF
ALL SYSTEMS IDENTIFIED IN COMMISSIONING AGENT'S DOCUMENTS, INCLUDING BUT NOT LIMITED TO LIGHTING CONTROLS, ELECTRONIC METERING, ETC.
GENERAL NOTES
ADDITIONAL NOTES
1. ALL INFORMATION REFERENCED IS PRELIMINARY IN NATURE AND DOES NOT REPRESENT FINAL DESIGN DOCUMENTS. ALL INFORMATION
AND REQUIREMENTS RELATIVE TO UTILITY INFRASTRUCTURE SHALL BE COORDINATED, VERIFIED, AND INSTALLED PER FINAL UTILITY COMPANY DESIGN DOCUMENTS.
2. ROUTING OF ALL CONDUIT SHALL BE COORDINATED IN THE FIELD AND CONFIRMED BY ENGINEER AND ARCHITECT.
3. COORDINATE ALL CONDUIT ROUTING, ELECTRICAL DEVICE LOCATIONS, PULL BOX LOCATIONS, ETC. WITH LANDSCAPE PLANTING PLANS TO AVOID CONFLICTS WITH TREES, SHRUBS, ETC.
4. ALL CONDUCTOR AND CABLE RUNS ARE TO BE CONTINUOUS. NO CONDUCTORS OR LOW VOLTAGE CABLING TO BE INSTALLED AS PART OF INCREMENT ONE. ALL CONDUCTORS AND LOW VOLTAGE CABLING TO BE INSTALLED AS PART OF INCREMENT TWO AND TERMINATED INSIDE OF THE BUILDING.
5. ALL CONDUIT SHALL BE PROVIDED WITH PROPERLY SIZED PULL STRING PER UTILITY COMPANY STANDARDS.
6. ALL EQUIPMENT MOUNTED OUTDOORS SHALL BE INSTALLED IN A WEATHERPROOF NEMA 3R ENCLOSURE.
7. SEE ARCHITECTURAL/LANDSCAPE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF FIXTURES, PULLBOXES, MANHOLES, OTHER ELECTRICAL DEVICES, ETC. COORDINATE ALL UNDERGROUND STRUCTURES AND CONDUIT ROUTING WITH LANDSCAPE ARCHITECT PRIOR TO ROUGH-IN TO ENSURE THAT SUCH ITEMS ARE NOT PLACED IN CRITICAL LANDSCAPE PLANTING/HARDSCAPE AREAS.
8. PROVIDE CONCRETE ENCASEMENT FOR ALL TRENCHES WITH MORE THAN THREE (3) CONDUITS. ALL UTILITY CONDUIT SHALL BE ENCASED PER UTILITY COMPANY REQUIREMENTS.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ELECTRICAL LEAD
SHEET
E0.02
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
GENERAL NOTES -LIGHTING FIXTURE/SCHEDULE
1. ALL LIGHTING FIXTURES SHALL BE LABELED WITH THE APPROPRIATE UL LABEL (DAMP, WET, ETC.) AS REQ BY CODES AND LOCAL ORDINANCES.
2. SHOP DRAWING SUBMITTALS SHALL INCLUDE ALL FIXTURES, AND DRIVERS/DIMMING INFORMATION. ANY SHOP DRAWINGS
WHICH ARE SUBMITTED WITHOUT ANY ONE OF THESE ITEMS WILL BE REJECTED AS INCOMPLETE AND WILL BE REQ TO BE RESUBMITTED WITH THE REQ INFORMATION.
3. ALL LIGHTING FIXTURE SPECIFIC INFORMATION (TYPE, OUTPUT/LUMEN LEVEL, DRIVER, COLOR, MOUNTING, ETC.) HAS BEEN SPECIFIED WITH THE CONSIDERATION OF SPECIFIC PERFORMANCE AND AESTHETIC REQUIREMENTS. ANY SUBSTITUTION OF THE SPECIFIED FIXTURES IS SUBJECT TO THE ARCHITECT AND ENGINEER OF RECORD ’S FINAL APPROVAL AND ARE SUBJECT TO THE FOLLOWING CRITERIA:
a. SUBMIT AN OPERABLE SAMPLE OF THE SPECIFIED FIXTURE AND A 120V CORD AND PLUG (AND DRIVER TO OPERATE SAMPLE IF NECESSARY).
b. PROVIDE COMPLETE PHOTOMETRIC REPORT(S) FOR THE SITE AND/OR FLOOR PLAN CONFIRMING SUBSTITUTE FIXTURE(S) MEET OR EXCEED DESIGNED ILLUMINANCE LEVELS IN SPACES IDENTIFIED. CLEARLY IDENTIFY ILLUMINANCE
LEVELS (IN FOOT -CANDLES), AND ALL INPUT DATA UTILIZED IN THE CALCULATION (LUMEN OUTPUTS, LIGHT LOSS FACTORS, ETC.). IN SITUATIONS WHERE SUBSTITUTIONS AFFECT FIXTURES EQUIPPED WITH EMERGENCY BATTERY
PACKS OR OTHER EMERGENCY SOURCES OF POWER, PROVIDE ADDITIONAL PHOTOMETRIC REPORT(S) THAT CLEARLY IDENTIFY A MIN OF 1 FOOT -CANDLE ALONG THE PATH(S) OF EGRESS, ALL INPUT DATA UTILIZED IN THE CALCULATION, AND THE LUMEN RATING AND QUANTITY OF FIXTURES FOR THE EMERGENCY BATTERY PACK. SEE BELOW FOR PHOTOMETRIC PLAN GUIDELINES:
1. POINT BY POINT SPACING IS NOT TO EXCEED 10’-0”IN ANY DIRECTION ON SITE PLANS; SPACING IS NOT TO EXCEED 4 ’-0”IN ANY DIRECTION ON INTERIOR FLOOR PLANS.
2. PHOTOMETRIC STUDY IS TO BE BASED ON MAINTAINED ILLUMINANCE LEVELS (IN FOOT -CANDLES) USING MEAN
FIXTURE LUMENS AND THE SAME LIGHT LOSS FACTORS USED IN THE ORIGINAL DESIGN CALCULATIONS PERFORMED BY THE ENGINEER OF RECORD.
3. ASSOCIATED REPORT TO INCLUDE AN ENERGY COST MODEL WHICH IDENTIFIES ADDITIONAL ENERGY OR ENERGY COSTS FOR A 10 -YEAR PERIOD AS COMPARED TO THE ORIGINAL ITEM SPECIFIED. ALL ADDITIONAL EXPENSES WILL BE SUBTRACTED FROM THE CONTRACT COST.
c. WHERE APPLICABLE, TEST SWITCH MOUNTING (INTEGRAL OR REMOTE) SHALL MATCH THE MOUNTING AS SPECIFIED ON THE DESIGN DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL COVER PLATES, TRIMS, REFLECTORS, ETC. NECESSARY FOR THE SPECIFIC TEST SWITCH MOUNTING.
d. MANUFACTURER ’S CATALOG CUT SHEET WHICH INCLUDES BUT IS NOT LIMITED TO THE FOLLOWING INFORMATION:
LUMEN LEVEL, DRIVER/TRANSFORMER OPTIONS, VOLTAGES, OPTICS, EPA RATING (WHERE APPLICABLE), FIXTURE DIMENSIONS, EMERGENCY OPTIONS (WHERE APPLICABLE), AND FIXTURE FINISHES. e. FOR ALL SITE LIGHTING FIXTURES, PROVIDE POLE SPECIFICATIONS WITH SUPPLEMENTAL DOCUMENTATION
IDENTIFYING POLE SIZE IS RATED ACCORDINGLY BASED ON FIXTURE(S) EPA AND WIND RATING FOR THE PROJECT ZONE.
f. A SIGNED COPY OF THE “SUBSTITUTION COMPLIANCE FORM ”LOCATED IN THE DIVISION 1 SPECIFICATION WHICH STATES
THAT IF THE PROPOSED SUBSTITUTION IS ACCEPTED, THEN THE PROJECT SCHEDULE WILL NOT BE NEGATIVELY AFFECTED. IF THE COMPLETION OF THE PROJECT IS DELAYED DUE TO THE PROPOSED SUBSTITUTION, THEN THE ELECTRICAL CONTRACTOR WILL BE RESPONSIBLE FOR ANY AND ALL ESTABLISHED LIQUIDATED DAMAGES. g. CONTRACTOR TO PROVIDE ARCHITECT AND ENGINEER OF RECORD WITH ALL SUBSTITUTE INFORMATION REFERENCED ABOVE NO LATER THAN TWO WORKING WEEKS PRIOR TO THE BID DEADLINE.
4. CATALOG NUMBERS AS REFERENCED ON THE FIXTURE SCHEDULE PROVIDE GENERAL FIXTURE INFORMATION.
CONTRACTOR SHALL REVIEW LIGHTING PLANS AND SPECIFICATIONS TO VERIFY ALL FIXTURE ASSOCIATED DESIGN INFORMATION. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY PARTS AND PIECES REQ FOR A COMPLETE AND OPERATIONAL INSTALLATION. ANY DISCREPANCIES BETWEEN DESCRIPTIONS, SPECIFICATIONS, AND
CATALOG NUMBERS ARE TO BE PRESENTED TO THE ENGINEER OF RECORD PRIOR TO COMPLETION OF THE BID PROCESS FOR CLARIFICATION.
5. ALL COLOR SPECIFIC INFORMATION WHICH RELATES TO LIGHTING FIXTURES AND/OR THEIR RELATED PARTS ARE TO BE REVIEWED AND COMMENTED ON BY THE ARCHITECT. FIXTURES WHICH REQUIRE A CUSTOM COLOR WILL HAVE A CUSTOM COLOR PAINT WHICH WILL BE INCLUDED IN THE ARCHITECT ’S SHOP DRAWING REVIEW COMMENTS.
6. ALL LIGHTING EQUIPMENT LOCATIONS ARE TO BE COORDINATED WITH THE ARCHITECTURAL REFLECTED CEILING PLAN PRIOR TO ORDERING AND INSTALLING.
7. ENSURE COMPATIBILITY OF ALL DIMMING SYSTEMS AND INDIVIDUAL LIGHTING CONTROLS WITH FIXTURES, AND DRIVERS.
ALL COMPONENTS TO BE FACTORY CERTIFIED COMPATIBLE FOR A FULL RANGE OF DIMMING.
8. LIGHTING FIXTURE CLEARANCES FROM COMBUSTIBLE MATERIALS ARE TO BE A MIN OF ½”(OTHER THAN AT POINTS OF SUPPORT) AND 3”FROM INSULATION FOR NON -IC RATED RECESSED LIGHTING FIXTURES.
9. ALL LIGHTING FIXTURES WHICH ARE TO BE MOUNTED IN FOOD SERVICE AREAS SHALL BE PROVIDED WITH THE FOLLOWING CHARACTERISTICS: DOOR TO FRAME GASKETS, LENS TO FRAME GASKETS, INVERTED LENS, AND A FOOD SERVICE RATING.
10. ALL LIGHTING FIXTURES TO BE MOUNTED IN A SUSPENDED CEILING ARE TO BE SUPPORTED BY T -BAR CLIPS AND (2) #12 SUPPORT WIRES ATTACHED TO THE BUILDING FRAME. IN ADDITION, LIGHTING FIXTURE ARE TO BE SECURED TO THE CEILING GRID WITH (4) SHEET METAL SCREWS ((1) AT EACH CORNER OF THE FIXTURE) –SCREWS SHALL BE NEITHER VISIBLE NOR IMPEDE THE INSTALLATION OF CEILING TILES; UON. WITH MANUFACTURER ’S INSTALLATION INSTRUCTIONS.
11. CONTRACTOR TO FOLLOW COLOR TEMPERATURE GUIDELINES LISTED BELOW UNLESS OTHERWISE NOTED OR SPECIFIED:
a. 3500K FOR ALL INTERIOR ENVIRONMENTS
b. 3000K FOR ALL EXTERIOR ENVIRONMENTS
12. CONTRACTOR TO FOLLOW CRI AND TM30 VALUES GUIDELINES LISTED BELOW UNLESS OTHERWISE NOTED OR SPECIFIED:
a. CRI 80 FOR INTERIOR
b. TM30 RF VALUE ≥78 FOR INTERIOR
c. TM30 RG VALUE ≥98 FOR INTERIOR
d. CRI 70 FOR EXTERIOR
13. ALL FIXTURES, TRIMS, AND MODULES/LAMPS SHALL BE CLEANED AND FREE FROM DIRT, DUST, LABEL/ADHESIVE, AND FINGER PRINTS.
14. IN THE EVENT OF THE FAILURE OF NORMAL POWER SUPPLIES, EMERGENCY LIGHTING FIXTURES SHALL BE AUTOMATICALLY POWERED BY AN EMERGENCY POWER SYSTEM. THE FIXTURE SHALL BE EITHER:
a. CIRCUITED TO AN EMERGENCY POWER SYSTEM, OR
b. EMERGENCY BATTERY PACKS ARE TO BE PROVIDED. WHERE EMERGENCY BATTERY PACKS ARE PROVIDED, EMERGENCY LIGHTING FIXTURES AND BATTERY PACKS ARE TO MEET THE FOLLOWING CRITERIA:
1. FIXTURES SPECIFIED WITH INTEGRAL EMERGENCY BATTERY PACKS ARE TO BE FED WITH/PROVIDED WITH A CONSTANT HOT CONNECTION TO THE CHARGING LEAD.
2. APPROVED EMERGENCY BATTERY PACKS SHALL BE PROVIDED AS FOLLOWS: BODINE #BSL23 OR #BSL722 OR EQUAL IF AVAILABLE.
3. ALL LED FIXTURES EQUIPPED WITH EMERGENCY BATTERY PACKS SHALL HAVE THE BATTERY PACKS FACTORY INSTALLED AND TESTED AT THE FIXTURE MANUFACTURER ’S FACILITY TO ENSURE UL LISTING OF THE FIXTURE IS MAINTAINED. FIELD INSTALLATION OF LED EMERGENCY BATTERY PACKS IS STRICTLY PROHIBITED. NOTIFY
ENGINEER OF RECORD SHOULD SPECIFIED FIXTURE NOT HAVE ADEQUATE SPACE TO ACCOMMODATE THE EMERGENCY BATTERY PACK. CONTRACTOR TO MODIFY BASE BID TO INCLUDE ALL NECESSARY EQUIPMENT FOR A
COMPLETE OPERATIONAL, ADEQUATELY SIZED MINIATURE INVERTER SYSTEM TO BE MOUNTED IN NEAREST ELECTRICAL ROOM IN THE EVENT THE BATTERY PACK CAN NOT BE INSTALLED IN THE FIXTURE.
4. ALL BATTERY PACKS ARE TO BE FACTORY INSTALLED IN FIXTURE ASSEMBLIES WHEN APPLICABLE. ELECTRICAL
CONTRACTOR IS RESPONSIBLE FOR CONTACTING FIXTURE MANUFACTURERS TO VERIFY SPECIFIED (OR APPROVED SUBSTITUTE) FIXTURE HAS ADEQUATE SPACE WITHIN THE FIXTURE TO MOUNT THE EMERGENCY BATTERY PACK. IF
IT IS DETERMINED THE BATTERY PACK CANNOT BE MOUNTED IN THE FIXTURE, THEN CONTRACTOR SHALL INCLUDE ALL COSTS REQ FOR REMOTE MOUNTING THE EMERGENCY BATTERY PACK ABOVE NEAREST ACCESSIBLE CEILING.
ENSURE DISTANCE FROM FIXTURE TO REMOTE BATTERY PACK LOCATION DOES NOT EXCEED THE MANUFACTURER ’S RECOMMENDED DISTANCES. COORDINATE ALL ACCESS PANELS WITH ARCHITECT OF RECORD PRIOR TO INSTALL.
5. ALL LIGHTING FIXTURES WITH EMERGENCY BATTERY PACKS ARE TO BE PROVIDED WITH INTEGRAL TEST SWITCHES AND CHARGE LIGHTS UNLESS OTHERWISE NOTED OR REQ BY THE AUTHORITY HAVING JURISDICTION (AHJ). IN THE
EVENT INTEGRAL TEST SWITCHES ARE NOT ALLOWED, NOTIFY THE ENGINEER OF RECORD PRIOR TO INSTALLATION OF REMOTE TEST SWITCHES. TEST SWITCHES TO BE INSTALLED IN FIXTURES WITH A MIN OF 18 ”OF ADDITIONAL WIRING TO ALLOW FOR GENERAL FIXTURE MAINTENANCE.
6. SHUNT UL 924 WILL BE PROVIDED IN CONTROL SYSTEM OR WITHIN FIXTURE TO RAISE EMERGENCY LIGHT FIXTURE TO 100% AT TIME OF EMERGENCY.
15. EMERGENCY ILLUMINATION UNITS SHALL BE ARRANGED TO PROVIDE AT LEAST AN AVERAGE OF 1 FOOT-CANDLE AND A MIN OF 0.1 FOOT -CANDLE MEASURED ALONG THE PATH OF EGRESS. A MAXIMUM -TO -MIN ILLUMINATION UNIFORMITY RATIO OF 40 -TO -1 SHALL NOT BE EXCEEDED. WHERE LOCAL CODES OR ORDINANCES REQUIRE MORE STRINGENT ILLUMINATION OR
CONTRAST RATIOS, EMERGENCY ILLUMINATION UNITS SHALL MEET OR EXCEED LOCAL CODE OR ORDINANCE REQUIREMENTS.
16. INSTALL ALL EXIT SIGNS IN ACCORDANCE WITH THE LOCAL AHJ AND FIRE AUTHORITY. THE CONTRACTOR IS RESPONSIBLE
FOR PROVIDING ALL REQ PARTS, PIECES, AND MOUNTING HARDWARE FOR EXIT SIGNS, AS WELL AS ENSURING THE EXIT SIGNS ARE MOUNTED IN AN APPROVED VISIBLE LOCATION. VERIFY ALL REQ CHEVRONS, MIRRORS, AND FACES ARE PROVIDED AS REFERENCED ON THE ARCHITECTURAL REFLECTED CEILING PLAN. NOTIFY ARCHITECT AND ENGINEER OF
RECORD OF ANY DISCREPANCIES BETWEEN ARCHITECTURAL AND ELECTRICAL DRAWINGS PRIOR TO ORDERING OF EQUIPMENT.
17. TRACK LIGHTING FIXTURE SPECIFICATIONS ARE TO BE COORDINATED, VERIFIED, AND CONFIRMED WITH EQUIPMENT MANUFACTURER AND/OR DISTRIBUTOR PRIOR TO ORDERING AND INSTALLING. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL NECESSARY PARTS AND PIECES FOR A COMPLETE, FUNCTIONAL, AND OPERATIONAL INSTALLATION. TRACK LENGTHS ARE AS SPECIFIED ON THE FIXTURE SCHEDULE.
18. CONTRACTOR SHALL INSTALL ALL LIGHTING FIXTURES PER LOCAL AND NATIONAL BUILDING, ELECTRICAL, AND SEISMIC CODES. CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL REQ MOUNTING HARDWARE AND BRACING MATERIALS FOR COMPLETE AND CODE COMPLIANT INSTALLATION. COORDINATE REQUIREMENTS WITH AUTHORITY HAVING JURISDICTION PRIOR TO INSTALLATION.
19. CONTRACTOR TO INCLUDE IN BASE BID A MIN OF 2-HOURS FOR A ONE TIME AIMING AND ADJUSTMENT TIME OF ALL MULTI- HEAD AND DIRECTIONAL FIXTURE ASSEMBLIES. AIMING AND ADJUSTMENT TO BE SCHEDULED FOR A NIGHT AND AFTER HOURS WITH THE ARCHITECT, ENGINEER, AND OWNER PRESENT. CONTRACTOR IS RESPONSIBLE FOR SCHEDULING AN APPROPRIATE TIME PRIOR TO ORDERING THE FINAL PUNCH WALK FOR THE PROJECT.
20. SUPPLEMENTARY OVERCURRENT PROTECTION PANEL FOR TRACK LIGHTING SYSTEMS TO BE PROMINENTLY LABELED AS FOLLOWS:
NOTICE: THIS PANEL FOR TRACK LIGHTING ENERGY CODE COMPLIANCE ONLY. THE OVERCURRENT PROTECTION DEVICES IN THIS PANEL SHALL ONLY BE REPLACED WITH THE SAME OR LOWER AMPERAGE. NO OTHER OVERCURRENT PROTECTIVE DEVICE(S) SHALL BE ADDED TO THIS PANEL. ADDING TO, OR REPLACEMENT OF EXISTING OVERCURRENT PROTECTIVE
DEVICE(S) WITH HIGHER CONTINUOUS AMPERE RATING, WILL VOID THE PANEL LISTING AND REQUIRE RESUBMITTAL AND RE -CERTIFICATION OF CALIFORNIA TITLE 24, PART 6 COMPLIANCE DOCUMENTATION.
21. LED DRIVERS SHALL CONFORM TO IEEE P1789 STANDARDS. ALTERNATIVELY, MANUFACTURERS MUST DEMONSTRATE CONFORMANCE WITH PRODUCT LITERATURE AND TESTING WHICH DEMONSTRATES THIS PERFORMANCE. SYSTEM THAT DO NOT MEET IEEE P1789 WILL NOT BE CONSIDERED.
22. LED DRIVERS WILL NOT HAVE VOLTAGE LEAK OR CONTAIN A FILTER WITHIN THE CONTROL MODULE TO CONTROL THE VOLTAGE LEAK AND REDUCE THE CHANCES OF FLICKERING.
23. LED DIODES SHALL BE SOURCED WITHIN 3 MACADAMS ELLIPSE ALONG THE BLACK BODY CURVE.
LIGHTING CONTROL SYSTEM REQUIREMENTS
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE FURNISHING OF ALL MATERIAL, LABOR, EQUIPMENT, AND SERVICES, IN CONNECTION WITH THE INSTALLATION OF A COMPLETE AND FULLY FUNCTIONING AND CODE COMPLIANT INSTALLATION.
2. IT IS THE INTENT OF THE CONTRACT DOCUMENTS, WHICH ARE PRESENTED IN A DIAGRAMMATIC FORMAT, TO PROVIDE
CONTRACTOR INFORMATION THAT SUPPLEMENTS AND ENHANCES THE GENERALLY ACCEPTED CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES EMPLOYED IN CONNECTION WITH INSTALLATION OF THIS TYPE OF PRODUCT / SYSTEM.
3. THE CONTRACTOR SHALL ALSO INCORPORATE THE REQUIREMENTS OF THE MANUFACTURER'S INSTALLATION INSTRUCTIONS / WARRANTY REQUIREMENTS AS PART OF THE REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS. IN THE
EVENT OF A CONFLICT BETWEEN THE CONTRACT DOCUMENT REQUIREMENTS AND THE MANUFACTURERS INSTALLATION
REQUIREMENTS, THE MORE STRINGENT REQUIREMENTS SHALL APPLY - UNLESS THE MORE STRINGENT REQUIREMENT VOIDS APPLICABLE WARRANTIES OR VIOLATES THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION. ANY
SUCH CONFLICT SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING THROUGH THE FORMAL RFI PROCESS.
4. REFER TO THE ASSOCIATED SCHEDULES, SCHEMATICS, DRAWINGS, AND SPECIFICATIONS FOR DETAILED INFORMATION / REQUIREMENTS ON THIS PRODUCT / SYSTEM.
5. LIGHTING CONTROL SYSTEM MUST INTERGRATE WITH DISTRICT APPROVED AUTOMATED LOGIC ENERGY MANAGAMENT SYSTEM.
6. PROVIDE (6) "SPARE" ADDITIONAL RELAYS.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
LIGHTING FIXTURE
NOTES, LIGHTING
FIXTURE & LCP
SCHEDULES
E0.20
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGZW2-T3 Exterior Wall Sconce (Type III)"BLDS W1X" series, wall mounted sconce, Type III distribution, provide custom canopy to cover the surface mounted j-box and allow for hard conduit, provide exterior occ sensors, all custom RAL to match adjacent finishes 58 VA 277V Integral 0-10V
dimming
LED 4,429lm 3000K 90+ Exterior B1-U0-G1 LUMENPULSE #BLDS-WM-277-CSL-S60-30K-CRI80-3FBLS-LV-CC-DIM-[Motion Detector]-[Mounting Adapter]
RAL# TBD Exterior
ZW1-T3 Exterior Wall Sconce (Type III)"BLDS W1H" series wall mounted sconce, Type III distribution, custom finish, half-frosted site lens, 1 LED board, after hours dim, integral dimming occupancy sensor and photocontrol, horizontal wall mount adapter for 2"x4" recessed junction... 58 VA 277V Integral 0-10V
dimming
LED 4,636lm 3000K 90+ Exterior B1-U0-G1 LUMENPULSE #BLDS-WM-277-HFSL-S60-30K-CRI80-3-LV-CC-DIM-[Motion Detector]-W1H2 RAL# TBD Exterior ZR1-18 18'-0" Exterior Recessed Linear (Metal Ceiling) Same as ZR1-8, except 18' in length 88.2 VA 120V Integral 0-10V dimming to 1%
LED 335lm/ft 3000K 90+ Exterior B1-U1-G1 SELUX #PT-ID20-830-LW-TS-18-SP-1-DIM RAL# TBD Exterior ZR1-14 14'-0" Exterior Recessed Linear (Metal Ceiling) Same as ZR1-8, except 14' in length 68.6 VA 120V Integral 0-10V dimming to 1%
LED 335lm/ft 3000K 90+ Exterior B1-U1-G1 SELUX #PT-ID20-830-LW-TS-14-SP-1-DIM RAL# TBD Exterior ZR1-12 12'-0" Exterior Recessed Linear (Metal Ceiling) Same as ZR1-8, except 12' in length 58.8 VA 120V Integral 0-10V dimming to 1%
LED 335lm/ft 3000K 90+ Exterior B1-U1-G1 SELUX #PT-ID20-830-LW-TS-12-SP-1-DIM RAL# TBD Exterior ZR1-8 8'-0" Exterior Recessed Linear (Metal Ceiling) "Peeta" series, recessed IP65 linear, 8' in length, LED optimized white lens, custom RAL finish to match exterior canopy, 4.9w/ft
39.2 VA 120V Integral 0-10V
dimming to 1%
LED 335lm/ft 3000K 90+ Exterior B1-U1-G1 SELUX #PT-ID20-830-LW-TS-08-SP-1-DIM RAL# TBD Exterior ZN1 15'-0" Pedestrian Pole Light "B84082" series, 12' pedestrian pole, finish custom RAL, universal voltage, motion sensor, locable weatherproof cover with base cover and pole 66 VA UNV Integral 0-10V
dimming
LED 4,572lm 3000K 80 Exterior B2-U0-G1 BEGA #B84082-K30-CUS RAL#RAL# TBD Exterior
LIGHTING FIXTURE SCHEDULE (SITE)
XW1 Wall Mounted Exit Sign "Sovereign II" series, wall surface mounted exit sign, single clear face with green letters, arrows per plan, trim and housing TBD
5 VA UNV n/a GREEN
LED
n/a GREEN Interior n/a EVENLITE #SOVII-AC-G-1C-CC-SW-[Chevrons per plan]-FP RAL# TBD General Throughout XM1 Mullion Mounted Exit Sign "Sovereign II" series, bottom surface mount mullion mounted legend exit sign, single clear face with green letters, arrows per plan, trim and housing TBD 5 VA UNV n/a GREEN
LED
n/a GREEN Interior n/a EVENLITE #SOVII-AC-G-1C-CC-MU-[Chevrons per plan]-IN (Bottom Surface Mount Inverted Legend)-FP
RAL# TBD General Throughout
W5-5DI 5'-0" Wall Mounted Linear (Direct/Indirect) "M36" series, 5' wall mounted direct/indirect linear, direct - optimized white lens,
8.7w/ft, indirect - LMO batwing lens, 6.1w/ft
55 VA UNV 0-10V Dimming to
1%
LED 637lm/ft (direct)
510lm/ft (indirect)
3500K 90+ Interior n/a SELUX #L36DI-1C25-1C20-835-LW-WB-W-5-SV-U-DIM Silver Restrooms W4 Column Mounted Downlight (Type II)"Lumenblade Nano" series, column mounted area light with Type II distribution, half frosted site lens, integral louver, horizontal wall mounting adaptor for 4" dia. Round exterior surface junction box.
30 VA 277V LED 2,500lm 3500K 90+ Interior n/a LUMENPULSE #BLDN-WM-277-HFSL-XS20-35K-CRI90-2-LV-CC-DIM-W1HSJB RAL# TBD Mezzanine - Interior Columns
W3-6DI 6'-0" Wall Mounted Linear (Direct/Indirect) "M36" series, 6' wall mounted direct/indirect linear, direct - optimized white lens,
8.7w/ft, indirect - LMO batwing lens, 6.1w/ft
80.4 VA UNV 0-10V Dimming to
1%
LED 988lm/ft (direct)
637lm/ft (indirect)
3500K 90+ Interior n/a SELUX #L36DI-1C30-1C25-835-LW-WB-W-6-SV-U-DIM Silver Restrooms W2-4 Wall Mounted Striplight (Elevator Pit)"Wall 3" series, 4' wall mounted striplight, vandal resistant 22.4 VA UNV 0-10V Dimming to 1%
LED 3,127lm 3500K 80 Interior n/a LIFESHIELD #W3B-4-35-LW-SFA-ED1-U White Elevator Pit W1-4 Wall Mounted Striplight (BOH)"CSL" series, 4' in length wall mounted strip light, frosted acrylic lens 36 VA UNV Integral 0-10V dimming to 1%
LED 4,850lm 3500K 90 Interior n/a COLUMBIA #CSL4-LSCS-MED-3500 White Elevator Machine Room 110
Mechanical Room 103
Fire Riser
S1 Surface Mounted Cylinder Downlight "M Surface Cylinder" series, 4" surface mounted cylinder downlight, wide flood optics, hexcell louver, jbox cover
24.5 VA UNV 0-10V Dimming to
1%
LED 2,000lm 3500K 90 Interior n/a DMF #DC4-SM-S-M-D-20-WF-H-00-00-35-WH-O-00 Jbox Cover: #DCCX-[Finish]
White Mezzanine - Under
Mezzanine Deck
R4 Recessed Flat Lensed 1x4 "NBT" series, recessed 1x4 light fixture, gyp ceiling, flat lens 24.7 VA UNV 0-10V Dimming to 1%
LED 3,161lm 3500K 80 Interior n/a COLUMBIA #NBT-14-35-L032-[Ceiling]-SF-ED1-U-R Smooth Frrosted Sheilding Janitor R3-20 20'-0" Recessed Linear (Tile)Same as R3-16, except 20' in length 146 VA UNV Integral, 0-10V dimming to 1%
LED 627lm/ft 3500K 90 Interior n/a SELUX #L60-1C30-935-LW-[Grid]-20-WH-U-DIM White Stem Classrooms 112 and 113
R3-16 16'-0" Recessed Linear (Tile)"M60" series, 16' in length recessed linear light fixture mounted in ACT ceiling,
7.3w/ft, LED optimized white lens, grid TBD, custom RAL finish, emergency circuit 116.8 VA UNV Integral, 0-10V
dimming to 1%
LED 627lm/ft 3500K 90 Interior n/a SELUX #L60-1C30-935-LW-[Grid]-16-WH-U-DIM White Stem Classrooms 112 and 113
R2 Recessed 2x2 Architectural Troffer "Fluxgrid" series, recessed 2x2 light fixture, grid mounting, diffuse flat smooth 29 VA UNV Integral 0-10V dimming driver to 1%
LED 3,800lm 3500K 80 Interior n/a DAY-BRITE #2-FGX-G-38L-935-2-FS-UNV-DIM White Staff Room 102 R1 4" Recessed Round Downlight "M Series 4" Round Downlight" series, 4" diameter recessed downlight, new construction, round apeture, fixed module, wide flood 60° optics, standard trim
14.3 VA UNV Integral 0-10V
dimming driver to 1%
LED 1,500lm 3500K 80 Interior n/a DMF Housing: #M4NCRN
Light Module: #MD-15-8-35-WF-O
Trim: #M4TRS-CW
Optics: #MDLX-WF
Reflector: Matte Diffuse
Trim: White
Conference Room 136
P3 4'-0" Pendant Mounted Striplight "CSL" series, 4' in length pendant mounted strip light, frosted acrylic lens 36 VA UNV Integral 0-10V dimming to 10%
LED 4850lm 3500K 90 Interior n/a COLUMBIA #CSL4-LSCS-MED-3500 White Mechanical Room 103 Electrical Room 104
IDF Room 105
P2-10DI 10'-0" Pendant Mounted Linear (Direct/Indirect) "M60" series, 10'-0" pendant mounted direct/indirect, direct batwing with satine lens, indirect wide batwing distribution, cable mounting
134 VA UNV Integral 0-10V
dimming to 1%
LED 627lm/ft 3500K 90+ Interior n/a SELUX #L6DI-1C30-1C30-935-BW-WB-C-10-WH-U-DIM Canopy: Matte White Fixture: Matte White
Storage 101
P1 Pendant Mounted Highbay "SCPL" series, high bay pendant mounted on flexible cable with 22" diameter frosted acrylic shade
170 VA UNV Integral 0-10V
dimming
LED 21700lm 3500K 90+ Interior n/a CONTECH
LIGHTING
#SCPL4-35KC-MVD2-CNH-FC-B-ACL22FR-B Canopy: Black
Cable: Black
Exterior Shade: Frosted
Acrylic
Exhibit Space 100
C1 Concealed Tapelight w/ Frosted Lens in
Continuous Channel (Undercabinet)
"Flex Mini Channel + Flex One HO Interior" series, concealed tape light, with extrusion/channel, frosted lens, 5.5w/ft. Provide length per plan; contractor to coordinate final length with plans and millwork shop drawings prior to purchase and installation. Include all hardware necessary for a complete installation, including mounting clips, drivers, and jumpers. Coordinate location of remote driver with millworker and interior designer prior to installation. Contractor to provide sketch for LPA to review.
5.5 VA/ft UNV Remote 0-10V
dimming driver to 1%
LED 555lm/ft 3500K 90 Interior n/a ACCLAIM Flex Mini Channel: #FLX-MIN-[Length per plan] Frosted Lens: #FLX-MIN-FL-[Length per plan]
Fixture: #-FLEXOHI-35-[Length per plan]
Mounting Clip: #FLX MIN MC
Provide all appropriate 0-10V dimmable drivers, mounting hardware, feed connectors, and endcaps as required.
Satin Silver Storage 101
Stem Classrooms 112
and 113
Type Name Description
Apparent
Load
Volta
ge Driver Source Lumens CCT CRI Condition
BUG
Rating Manufacturer Model Number Finish Location
Electrical Source Manufacturer
LIGHTING FIXTURE SCHEDULE (BUILDING)
LIGHTING CONTROL PANEL SCHEDULE LCPA
Relay Number Panel Circuit Number Load Name Control Method 1 HLA 9 SITE LGT (LCPA)VIA TIMECLOCK/PHOTOCELL
2 INV-A 2 EM SITE LGT (LCPA)VIA TIMECLOCK/PHOTOCELL
LIGHTING CONTROL PANEL SCHEDULE LCPB
Relay Number Panel Circuit Number Load Name Control Method 1 LPS1 51 EXTERIOR LGT (LCPB)VIA TIMECLOCK/PHOTOCELL
2 LPS1 53 EM LGT. VIA INVERTER (LCPB)VIA TIMECLOCK/PHOTOCELL
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ELECTRICAL DEMO
SITE PLAN
E1.01
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGx x xxxxxxxxxxxxxx21"SS16"SS co co10"SS12"SS81"SDco
EEEEEEEEEE
EEEEE E E E E EEEEEE E E
EEEEEEEEEEx
x
x x x x x x x x x
x x x x
x x
x
x
EXISTING BLDG
NCOLUMBIA WAYLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKELECTRICAL DEMO SITE PLAN
PROPERTY LINEPROPERTY LINEKEYNOTES
DEMOLISH EXISTING LIGHT FIXTURE, FOOTING AND BRANCH
CONDUIT, CAP OFF WHERE SHOWN.1
GENERAL NOTES
1 2
2 DEMOLISH EXISTING CONDUITS AND WIRES WHERE SHOWN.
EC TO VERIFY CONDUCTORS SIZES DURING DEMOLITION
PHASE TO USE APPROPRIATE WIRES SIZE WHEN SPLICING.
2 1. REFER TO CIVIL DEMOLITION DRAWING C1.01 FOR MORE
INFORMATION.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ELECTRICAL SITE
PLAN
E1.11
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGx x xxxxxxxxxxxxxx21"SS16"SS 10"SS12"SS81"SD12"DW12"DW12"DW
6"FW
EEEEEEEEEE
EEEEE E E E E EEEEEE E E
EEEEEEEEEE2"GT
DCDA
PIV
FACP
ANN
T
T
WP
WP
WP
WP
WP
B
WP
WP
WP
EXISTING BLDG
NCOLUMBIA WAYLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKELECTRICAL SITE PLAN
PROPERTY LINEPROPERTY LINESTEM
BLDG
MAIN BLDG
KEYNOTES
UTILITY TRANSFORMER BY SCE.1
EC TO PROVIDE (2) 5" CONDUITS BURRIED AT 30" DEPTH AND
WITH PULL STRINGS FOR MAIN SERVICE FEEDERS. CONDUITS
GOING TO UTILITY POLE.
2 SEE E5.01 FOR FEEDER SCHEDULE. AND REFER TO DETAILS
09/E7.01 FOR UNDERGROUND DUCTBANK SECTION DETAILS.
3 CONNECT SECONDARY FEEDER FROM UTILITY TRANSFORMER
TO MAIN SWITCHBOARD. SEE E5.01 FOR FEEDER SCHEDULE.
4 REFER TO 10/E7.01 FOR TYPICAL PULLBOX DETAIL.5
SEE E5.01 FOR FEEDER SCHEDULE AND REFER TO FIRST
FLOOR POWER PLAN E2.01 FOR FEEDER ROUTING.
6 INSTALL NEW CONDUITS AND WIRES FOR EXISTING LOAD,
SPLICE CONDUCTORS AT PULL BOX WITH MATCHING WIRING
SIZES TO EXISTING ELECTRICAL LINE TO REMAIN CIRCUIT
CONNECTION CONTINUITY.
7 FEEDER PROVISION FOR FUTURE BATTERY ENERGY STORAGE
SYSTEM. REFER TO E5.01 FOR MORE INFORMATION8
1000-4 4
2 1
100-4S
(1)-
(1)-
5 CONCRETE PAD
(N)18"x24" PB
150-4S(1)-
(1)-
+(1) 2" C.O.
LMS1
LPS1
3 6
(N)11"x17" PB
(N)11"x17" PB
7 7
(N)11"x17" PB
(N) FA PULL BOX,
18" X 24"
(N) 1" UG C. FA
(N) 1" UG C. FA
(N) 2" UG C. FA
(N) FA PULL BOX,
11" X 17"(N) 2" UG C. FA
7 TO (E) LOAD+ (1) 2" C.O.
+ (N) WIRE & CONDUIT
FOR EXISTING LOAD
8 100-4S
150-4S
KEYNOTES
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
x x xxxxxxxxxxxxxx21"SS16"SS
10"SS12"SS81"SD12"DW12"DW12"DW
6"FW
EEEEEEEEEE
EEEEE E E E E EEEEEE E E
EEEEEEEEEE2"GT
DCDA
PIV
FACP
ANN
T
T
WP
WP
WP
WP
WP
B
WP
WP
WP
EXISTING BLDG
NCOLUMBIA WAYLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKELECTRICAL SITE PLAN
PROPERTY LINEPROPERTY LINESTEM
BLDG
MAIN BLDG
KEYNOTES
UTILITY TRANSFORMER BY SCE.1
EC TO PROVIDE (2) 5" CONDUITS BURRIED AT 30" DEPTH AND
WITH PULL STRINGS FOR MAIN SERVICE FEEDERS. CONDUITS
GOING TO UTILITY POLE.
2 SEE E5.01 FOR FEEDER SCHEDULE. AND REFER TO DETAILS
09/E7.01 FOR UNDERGROUND DUCTBANK SECTION DETAILS.
3 CONNECT SECONDARY FEEDER FROM UTILITY TRANSFORMER
TO MAIN SWITCHBOARD. SEE E5.01 FOR FEEDER SCHEDULE.
4 REFER TO 10/E7.01 FOR TYPICAL PULLBOX DETAIL.5
SEE E5.01 FOR FEEDER SCHEDULE AND REFER TO FIRST
FLOOR POWER PLAN E2.01 FOR FEEDER ROUTING.
6 INSTALL NEW CONDUITS AND WIRES FOR EXISTING LOAD,
SPLICE CONDUCTORS AT PULL BOX WITH MATCHING WIRING
SIZES TO EXISTING ELECTRICAL LINE TO REMAIN CIRCUIT
CONNECTION CONTINUITY.
7 FEEDER PROVISION FOR FUTURE BATTERY ENERGY STORAGE
SYSTEM. REFER TO E5.01 FOR MORE INFORMATION8
1000-4 4
2 1
200-4S+(1)-
5 CONCRETE PAD
(N)18"x24" PB
200-4S+(1)-+(1) 2" C.O.
LPS1
3 6
(N)11"x17" PB
(N)11"x17" PB
7 7
(N)11"x17" PB
(N) FA PULL BOX,
18" X 24"
(N) 1" UG C. FA
(N) 1" UG C. FA
(N) 2" UG C. FA
(N) FA PULL BOX,
11" X 17"(N) 2" UG C. FA
7 TO (E) LOAD+ (1) 2" C.O.
+ (N) WIRE & CONDUIT
FOR EXISTING LOAD
8 KEYNOTESKEYNOTES
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
LIGHTING SITE
PLAN
E1.21
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGx x xxxxxxxxxxxxxxZN1 (TYP)
E-1201
ZN1
(TYP)
E-1201
EM
EM
EM
ZN1
(TYP)
E-1201
EXISTING BLDG
NCOLUMBIA WAYLIMIT OF WORKLIMIT OF WORK LIMIT OF WORKLIGHTING SITE PLAN
PROPERTY LINEPROPERTY LINESTEM
BLDG
MAIN BLDG
KEYNOTES
PEDESTRIAN POLE
GENERAL NOTES
E-1201
(N) LIGHTING PULL BOX
11" X 17"
INV-A - 2
#10
9 2
2 2
9 9
9 9
9 9
9 9
9 9
HLA - 9
#10
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
CMMWREF.TVTVPRINTWP
WP WPWPWP WP
WPDFWP
WPTVF
F FFFM
M
M
MF
J
JJJJ FM
M
JJFFFFJJFJJJWP
JTV F
J
GMWJTVTTJ J J J J
JJJJJ JJFJWP
WP WP
M
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
11 10
10 12
G G
B B
C C
D D
E E
STEM
CLASSROOM
113
STEM
CLASSROOM
112
STAFF
ROOM
102
MEN'S
RESTROOM
106
MECHANICAL
ROOM
103
ELECTRICAL
ROOM
104
IDF
ROOM
105
FAMILY
RESTROOM
108
NURSING
ROOM
116
WOMEN'S
RESTROOM
107
EXHIBIT
SPACE
100
STORAGE
101
ELEVATOR
111
ELEVATOR
MACHINE
ROOM
110
LP1A
LP1B
LM1A
HMA
E4.01
02 AHU-1
AHU-2
VRF-3
VFC-4
VFC-1
VFC-3
VFC-2
CU-2
CU-1
LPS1
VRF-1
VRF-2
FC-1
FC-2
TYP.
E-1401
TYP.
E-1403
TYP.
E-1408
TYP.
E-1401
TYP.
E-1402
E-1406
E-1407
E-1405
E-1409
E-1411
E-1412
EF-1
STAFF
RESTROOM
114
E-1418
3 9
21 LP1A - 13
LP1A - 15
LP1A - 17
LP1A - 19
LP1A - 21
LP1A - 22
LPS1 - 30,32
E-1414
LP1A - 1
LP1A - 3
LP1A - 5,7,9
4 4 4 6 6 6 12
1214
101010888
18 18 16 16
12 LP1A - 14,16,18
14 14
LP1A - 8,10,12
LP1A - 2,4,6
2 2
2 2
2 20
20 20 20 20
29 29
31 31
33 33
7 7 5
5 5
5 5
9 9
9 HMA - 7,9,11
FS-1
LPS1 - 3,5
LM1A - 5,7
LP1A - 23
LP1B - 5
HMA - 8,10,12
LM1A - 6,8
HMA - 13,15,17
HMA - 14,16,18
HMA - 19,21,23
HMA - 20,22,24
HMA - 25,27,29
HMA - 26,28,30
TYP.
E-1401
TYP.
E-1402
LP1B - 3
LP1A - 11
33 25 25
25 11
11 11
11 1125
25 LM1A - 1,3
E-1406
5 23
23 23
21 21
21 27
27 27
27 555
5 MSB-A - 2
LP1B - 7
LP1B - 9
E-1421
LP1B - 1
HMA - 31,33,35
LP1A - 27 LM1A - 2,4
LP1A - 20
TYP.
E-1422
E-1423
LP1B - 11
LCPB
FA-CAB
LP1A - 31
LP1A - 29
LP1A - 25
LPS1 - 25,27
LPS1 - 26,28
1 1
1 1
LPS1 - 1
2 2
2 4
4 4
LPS1 - 2,4
LPS1 - 29,31
5 5
5 5
3 3 3
E-1423
LP1A - 33
GROUND BUSBAR
KEYNOTES
1. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET 24" MINIMUM.
2. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL.
3. COORDINATE ALL MOUNTING DIMENSIONS FOR ELECTRICAL DEVICES AND SWITCHES WITH ARCHITECTURAL INTERIOR ELEVATIONS PRIOR TO ROUGH-IN.
4. ALL FURNITURE FEED LOCATIONS TO BE VERIFIED WITH ARCHITECT AND FURNITURE VENDOR PRIOR TO ROUGH IN..
5. ALL FURNITURE WHIPS SHALL BE TRIMMED TO REDUCE EXCESS WHIP LENGTH
6. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR WILL NEED TO PROVIDE THE FOLLOWING ITEMS:
A. ALL BRANCH CIRCUITS SHALL BE IN EMT.
B. ALL BRANCH CIRCUITS SHALL BE ROUTED NEATLY AND IN PARALLEL TO STRUCTURES OR DUCT WORK.
C. VISUALLY OBJECTIONABLE BRANCH CIRCUITS WILL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST.
7. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC WHERE ADOPTED, ARTICLE 300.22(C.
8. PROVIDE G.F.C.I. TYPE RECEPTACLE(S) WITHIN 6 FEET OF ANY SINK.
9. CONTRACTOR TO INCLUDE AN ALLOWANCE TO CORE AND SEAL PENETRATIONS THROUGH STRUCTURAL CONCRETE WALLS. COORDINATE LOCATIONS AND REQUIREMENTS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS.
10. COORDINATE ALL PENETRATIONS WITH STRUCTURAL PLANS AND DETAILS. NO PENETRATIONS ARE PERMITTED UNLESS SPECIFICALLY NOTED ON STRUCTURAL DRAWINGS.
GENERAL NOTES
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
FIRST FLOOR
POWER PLAN
E2.01
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
1/8" = 1'-0"
1 -FLOOR -POWER 1
ITEM DESCRIPTION
E-1401 PROVIDE DISCONNECT SWITCH FOR AC UNIT PER MANUFACTURER'S REQUIREMENTS.
SEE SCHEDULES ON SHEET E5.21 FOR ADDITIONAL INFORMATION. VERIFY EXACT LOCATION WITH MECHANICAL DRAWINGS. PROVIDED AND INSTALLED BY MECHANICAL CONTRACTOR. POWERED BY ELECTRICAL CONTRACTOR.
E-1402 PROVIDE 3/4"C.O. WITH PULL STRINGS TO EMS PANEL FOR CONTROL CIRCUIT.
E-1403 PROVIDE 1" CONDUIT FOR POWER CONTROL AND CONNECT BACK TO CORRESPONDING FAN COIL UNIT.
E-1405 PROVIDE AND INSTALL DRINKING FOUNTAIN RECEPTACLE AT HEIGHT PER MANUFACTURER'S RECOMMENDATION. COORDINATE LOCATION WITH ARCHITECTURAL ELEVATION PRIOR TO ROUGH-IN.
E-1406 PROVIDE 120V POWER FOR ELECTRIC TRAP PRIMER, INSTALL PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE LOCATION WITH PLUMPING PRIOR TO ROUGH-IN.
E-1407 PROVIDE 480V 3 PHASE POWER CONNECTION TO EWH-1 UNIT. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE LOCATION WITH PLUMPING PRIOR TO ROUGH-IN.
E-1408 PROVIDE 208V SINGLE PHASE POWER CONNECTION TO EWH-2, UNIT TO BE INSTALL UNDER CABINET. INSTALL PER MANUFACTURER'S RECOMMENDATIONS. COORDINATE LOCATION WITH PLUMPING PRIOR TO ROUGH-IN.
E-1409 FEEDERS TO RUN ABOVE FIRST FLOOR CEILING AND DOWN TO GROUND TO FEED ELECTRICAL PANELS IN STEM BUILDING. SEE SITE PLAN FOR CONTINUATION.
E-1411 ELEVATOR DISCONNECT. INTERCONNECT WITH ELEVATOR MOTOR CONTROLLER PER MANUFACTURER RECOMMENDATIONS. REFER TO DETAIL 09/E7.02 FOR INSTALLATION DETAILS AND 07/E4.01 FOR WIRES AND FUSE SIZING.
E-1412 PROVIDE A 30AS/20AF/1P LOCKABLE FUSED DISCONNECT SWITCH WITH NEUTRAL FOR ELEVATOR CART. SEE DETAIL 09/E7.02 FOR MORE INFORMATION.
E-1414 PROVIDE 120V POWER CONNECTION FOR TV SCREEN. COORDINATE WITH ARCHITECT FOR FINAL LOCATION PRIOR ROUGH-IN.
E-1418 PROVIDE COMPLETE POWER CONNECTION TO DOOR OPERATOR ASSISTANT.
E-1421 CONNECT THE GFCI RECEPTACLE AND THE LIGHT SWITCH ALONG WITH THE IMPACT RESISTANT PIT LIGHT FIXTURES. LIGHTS TO NOT BE CONNECTED TO LOAD SIDE OF GFCI OUTLET. LOCATE SWITCH PER MANUFACTURER'S RECOMMENDATIONS. SEE SHEET E3.01 FOR LIGHT LOCATIONS AND TYPES. REFER TO DETAIL 9/E7.02 FOR INSTALLATION DETAILS.
E-1422 PROVIDE POWER FOR LOW VOLTAGE CONVERTER FOR PLUMBING URINAL SENSOR.
REFER TO PLUMING FIXTURE SCHEDULE FOR COMPLETE INFORMATION. REFER TO MANUFACTURER INSTALLATION GUIDE.
E-1423 POWERED FROM OUTDOOR UNIT VIA MOTOR RATED TOGGLE SWITCH. PROVIDE AND INSTALL 3/4" CONDUIT WITH WIRES PER MANUFACTURER AND AS REQUIRED FOR COMPLETE AND WORKABLE INSTALLATION. COORDINATE WITH HVAC CONTROL CONTRACTOR.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
J
J
J
J J
J
F
F
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
11 10
10 12
G G
B B
C C
D D
E E
CF-1
CF-2
LP2A
E-1410
E-1410
E-1416
LP2A - 1,3,5
LP2A - 2,4
2 2 2
2 2
2 4
4 4
4 4
EXHIBIT
SPACE
100
3 3
3 1
1 1
LP1B - 2
LP1B - 6
LP1B - 8
LP1B - 4 LP1B - 12
LP1B - 10
LP2A - 7
4 E-1410 E-1410
HMA - 1,3,5
HMA - 2,4,6
E-1419
TYP.
E-1420
77 7 5 5 5
KEYNOTES
1. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES AND OFFSET 24" MINIMUM.
2. ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE WITH AN APPROVED FIRESTOP SYSTEM EQUAL OR GREATER THAN THE FIRE RATING OF THE WALL.
3. COORDINATE ALL MOUNTING DIMENSIONS FOR ELECTRICAL DEVICES AND SWITCHES WITH ARCHITECTURAL INTERIOR ELEVATIONS PRIOR TO ROUGH-IN.
4. ALL FURNITURE FEED LOCATIONS TO BE VERIFIED WITH ARCHITECT AND FURNITURE VENDOR PRIOR TO ROUGH IN..
5. ALL FURNITURE WHIPS SHALL BE TRIMMED TO REDUCE EXCESS WHIP LENGTH
6. WHEN EXPOSED CEILINGS OR OPEN GRID CONDITIONS OCCUR, THE CONTRACTOR WILL NEED TO PROVIDE THE FOLLOWING ITEMS:
A. ALL BRANCH CIRCUITS SHALL BE IN EMT.
B. ALL BRANCH CIRCUITS SHALL BE ROUTED NEATLY AND IN PARALLEL TO STRUCTURES OR DUCT WORK.
C. VISUALLY OBJECTIONABLE BRANCH CIRCUITS WILL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDITIONAL COST.
7. EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC WHERE ADOPTED, ARTICLE 300.22(C.
8. PROVIDE G.F.C.I. TYPE RECEPTACLE(S) WITHIN 6 FEET OF ANY SINK.
9. CONTRACTOR TO INCLUDE AN ALLOWANCE TO CORE AND SEAL PENETRATIONS THROUGH STRUCTURAL CONCRETE WALLS. COORDINATE LOCATIONS AND REQUIREMENTS WITH ARCHITECTURAL AND STRUCTURAL DRAWINGS.
10. COORDINATE ALL PENETRATIONS WITH STRUCTURAL PLANS AND DETAILS. NO PENETRATIONS ARE PERMITTED UNLESS SPECIFICALLY NOTED ON STRUCTURAL DRAWINGS.
GENERAL NOTES
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SECOND FLOOR
POWER PLAN
E2.02
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
1/8" = 1'-0"
2 -FLOOR -POWER 1
ITEM DESCRIPTION
E-1410 PROVIDE COMPLETE POWER CONNECTION FOR GATE OPENER. INSTALL PER MANUFACTURER RECOMMENDATION.
E-1416 PROVIDE 120V POWER CONNECTION FOR PROJECTOR SCREEN. REFER TO ARCHITECTURAL PLAN EXACT LOCATION.
E-1419 PROVIDE 120V POWER CONNECTION FOR PROJECTOR. COORDINATE WITH ARCHITECT FOR FINAL LOCATION PRIOR ROUGH-IN.
E-1420 PROVIDE 480V POWER CONNECTION FOR CEILING FAN. REFER TO SCHEDULE ON SHEET E5.21 FOR DISCONNECT AND WIRE SIZING.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
B B
C C
D D
E E
ROOF ACCESS
E-1501
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ELECTRICAL
POWER ROOF PLAN
E2.03
08/01/2025
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING1/8" = 1'-0" R -ROOF -POWER 1
N
ITEM DESCRIPTION
E-1501 PROPOSED CONDUIT STUB UP FOR PV
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
REF.TVTVCGOP
OS
OP
OS
OS
OS
OSOS
OSOS
OS
OS
OS
OS
OS
OS
OS
OS
OSOSOSOSOS OOSZ-3BK
KMZ4-8B
MZ4-8BMZ-4BMZ-4BSZ-3B
UNITOUCHOS
OS
OS
OPLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLED OOS
LEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDOSUNITOUCH EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EMEMEMEM
EM
EM EM
EMEM
EM EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
11 11
10 10
12 12
G G
B B
C C
D D
E E
STEM
CLASSROOM
113
STEM
CLASSROOM
112
MEN'S
RESTROOM
106
MECHANICAL
ROOM
103
ELECTRICAL
ROOM
104
IDF
ROOM
105
FAMILY
RESTROOM
108
NURSING
ROOM
116
WOMEN'S
RESTROOM
107
EXHIBIT
SPACE
100
STORAGE
101
ELEVATOR
111
ELEVATOR
MACHINE
ROOM
110
(TYP.)
R1
(TYP.)
S1
ZR1-18
ZR1-14
ZR1-12
ZR1-8R3-16
R3-16
R3-20
R3-16
R3-20
R3-20
STAFF
RESTROOM
114
XW1XM1
(TYP.)
ZW1-T3
STAFF
ROOM
102
W1-4
(TYP.)
P3
(TYP.)
P3
(TYP.)
ZW1-T3
4 4 a 4 a
4 a 3 a
4 a
a4
a4a4
b b b
3 b b 3 b
b b b
3 b b 3 b
b b bb3bbb3bbb3bbb3bbb
49 C1
49 C1
W3-6DI W3-6DI
R4
(TYP.)
R1
XW1
3 4
4 4
3 4
3 4
4 3
4 3
(TYP.)
W1-4
a
b b
b b
b b
4 C1
c
4 4
4 3
abc
abc
1 1 1 1 1 1 1
1 1
1 5149
53 49
49 53
49 1
9 9
(TYP.)
W2-4
a
b
a
a
a
a
a aa
51 aa
53 aa
51 aa
1 bb bb bb bb bb bb
bb
bb
bb
4?
4 4
4 4W5-5DI
W5-5DI
R1
4 4
b
LPS1 - 51
E-1301
E-1301
E-1301
E-1312
E-1302
E-1304
E-1306
E-1306
c
abcdef
abcdef
E-1312
E-1312
E-1312
E-1312
3 P3
a
a
a
E-1313
E-1313
4 4 4
3 3
3 3
HLA - 1
3 33
3 4
4 4 4
3 3
3 3
E-1305
(TYP.)
P2-10DI
LPS1
E-1314
LPS1 -
149
LPS1 -53
SEE E2.01
INV-A - 1
INV -A -3
4 4 4
44 4 4 4
4 4 4
4 4 44
4 4
2 2 2
2 2 2
2 2 22222222222
E-1303
HLA - 2
HLA - 4
KEYNOTES
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
FIRST FLOOR
LIGHTING RCP
E3.01
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
ITEM DESCRIPTION
E-1301 FIXTURE TO BE CONCEALED BEHIND LIP OF CABINET. LOCATE REMOTE DIRVER FOR TYPE C1 ABOVE TILE CEILING THAT IS TO BE ACCESSIBLE FOR MAINTENANCE. RUN WIRING BEHIND WALL AND EXIT WHERE FIXTURE MEETS WALL. HOLE IN WALL TO BE
CLEAN, MINIMAL, AND HIDDEN BEHIND LIP OF CABINET SUCH THAT IT IS NOT VISIBLE FROM VIEW. PROVIDE SMALLEST DIAMETER CABLE GROMMET THAT IS APPROPRIATE WHERE WIRING PASSES THROUGH MILLWORK. GROMMET FINISH TO MATCH AS CLOSE TO MILLWORK FINISH. ALL WIRING SHOULD BE INSTALLED CLEAN, NEAT, CONCEALED, AND RUN TIGHT TO BUILDING ELEMENTS/MILLWORK WHERE POSSIBLE.
E-1302 TYPE S1 TO BE SURFACE MOUNTED UNDER MEZZANINE DECK.
E-1303 TYPE S1 TO BE SURFACE MOUNTED UNDER STAIRS.
E-1304 CENTERLINE OF TYPE W1-4 TO BE MOUNTED AT 9'-0" A.F.F.
E-1305 BOTTOM OF TYPE P2-10DI TO BE MOUNTED AT 10'-0" A.F.F.
E-1306 BOTTOM OF TYPE P3 TO BE MOUNTED AT 10'-0" A.F.F.
E-1312 TYPE ZR1 SERIES TO BE RECESSED INTO METAL CEILING.
E-1313 CENTERLINE OF TYPE ZW1-T3 TO BE MOUNTED AT 27'-0" A.F.F. INTENT IS FOR FIXTURE TO SIT CENTERED HORIZONTALLY AND VERTICALLY IN SCORE JOINTS.
E-1314 INSTALL BODINE 400VA EMERGENCY BATTERY MINI INVERTER FOR EMERGENCY LIGHTING CIRCUIT. MOUNT INVERTER ABOVE CEILING.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
HOS
HOS
HOS HOS HOS OS OS
HOS OS OS
HOS HOS OS OSHOS
UNITOUCH
EM EM
EM
EM
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
B B
C C
D D
E E
(TYP.)
ZW2-T3
ELEVATOR
111
6 f 6 f 6 f 6 f 6 f 6 f 6 f
5 d 5 d 5 d 5 d 5 d 3 d 3 e 3 e 3 e 3 e 3 e
4 d 5 d 4 d 3 d 4 e 3 e 3 e 4 e 3 e
5 d d 5 d 5 d d 3 d 3 e 3 e 3 e 3 e 3 e
4 d d 5 d 4 d d 3 d 4 e 3 e 3 e 4 e 3 e
4 cc 7 cc 7 cc 4 cc 7 cc 7 cc 7 cc 7 cc 7 cc
5 5
5 d
5 d
5 5
(TYP.)
W4
(TYP.)
P1
INV-A - 4
HLA - 3
HLA - 5
HLA - 7
HLA - 6
EM
EM EM EM
EMEM EM
EM
4 4
(TYP.)
W1-4
abcdefE-1307
E-1308
E-1312
E-1310
E-1311
KEYNOTES
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SECOND FLOOR
LIGHTING RCP
E3.02
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING1/8" = 1'-0" 2 -FLOOR -LIGHTING 1
N
ITEM DESCRIPTION
E-1307 BOTTOM OF TYPE P1 TO BE MOUNTED AT 40'-0" A.F.F.
E-1308 TOP OF TYPE W4 TO BE MOUNTED AT 24'-0" A.F.F. INTENT IS TO ALIGN WITH SEAM OF COLUMN.
E-1310 CENTERLINE OF TYPE W1-4 TO BE MOUNTED AT 5'-0" ABOVE METAL GRATE LANDING.
E-1311 CENTERLINE OF TYPE W1-4 TO BE MOUNTED AT 10'-0" A.F.F.
E-1312 TYPE ZR1 SERIES TO BE RECESSED INTO METAL CEILING.
8 8
A A
B B
C C
LP1ALP1BLM1ALL1A
HMA
HLA
MSB-A
DB-A
T-A
ELECTRICAL
ROOM
104
IDF
ROOM
105
E-1701
E-1703
E-1705
E-1703
E-1706
(TYP)
INV-A
LCPA
E-1413
LL1A - 5
LL1A - 1
LL1A - 2,4
LL1A - 6,8
LL1A - 3
E-1707
TYP.
E-1708
E-1709
KEYNOTES
1. CONTRACTOR TO FIELD VERIFY ALL CONDITIONS PRIOR TO ROUGH-IN.
2. ALL ROUTING SHOWN ON ELECTRICAL DRAWINGS ARE DIAGRAMATIC. CONTRACTOR TO VERIFY IN FIELD EXACT LOCATION OF FINAL ROUTING AND COORDINATE WITH ARCHITECT PRIOR TO INSTALLATION.
3. CONTRACTOR TO VERIFY POWER REQUIREMENTS BEFORE ORDERING ELECTRICAL DEVICES.
4. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR ADDITIONAL CONNECTION TO CONTROL PANELS, SWITCHES, VALVES, STATS, RALY, ETC. INDICATED ON MECHANICAL CONTROL DIAGRAMS. ELECTRICAL CONTRACTOR SHALL VERIFY FINAL CONTROL WIRING REQUIREMENTS WITH ACTUAL EQUIPMENT TO BE INSTALLED PRIOR TO ANY WORK AND PROVIDE ALL NECESSARY CIRCUITS, DEVICES, AND CONNECTIONS AS REQUIRED.
5. CONTRACTOR SHALL VERIFY ACTUAL MECHANICAL EQUIPMENT TO BE INSTALLED AND PROVIDE FUSED DISCONNECT SWITCHES WHEN SUCH EQUIPMENT U.L. LISTING AND/OR LABELING INDICATED MAXIMUM FUSE FOR EQUIPMENT PROTECTION.
GENERAL NOTES
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025As indicatedCOLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ENLARGED
ELECTRICAL/DATA
PLAN AND DETAILS
E4.01
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING1/4" = 1'-0" 1 -FLOOR -POWER -MAIN -ENLARGED ELECTRICAL AND IDF ROOM 02
ITEM DESCRIPTION
E-1413 PROVISION FOR FUTURE PV AND BATTERY PACK.
E-1701 MAIN GROUND BUS BAR. REFER TO DETAIL 01/E7.01 FOR MORE INFORMATION.
E-1703 REFER TO STRUCTURAL DETAIL 01/S6.91 FOR FLOOR MOUNTED EQUIPMENT ANCHORAGE INFORMATION.
E-1705 REFER TO DETAIL 11/E7.02 FOR MORE INFORMATION.
E-1706 INSTALL PANIC DOOR HARDWARE PER CEC 110.26(C)(30).
E-1707 PROPOSED 2" C.O. FOR PV CONNECTION
E-1708 PROVIDE 208V SINGLE PHASE POWER CONNECTION FOR RECEPTACLE WITH L6-30R TYPE. COORDINATE WITH LOW VOLTAGE CONSULTANT PRIOR ROUGH-IN E-1709 FIRE ALARM PANELS. REFER TO FIRE ALARM DRAWINGS FOR MORE INFORMATION.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
LP1A
PANEL
L=18'
VD=0.20%125-4LP1B
PANEL
L=20'
VD=0.25%100-4LP2A
PANEL
L=42'
VD=0.55%70-4HMA
PANEL
HLA
PANEL
DISTRIBUTION BOARD 'DB-A'
500A, 208/120V, 3 ⌀, 4W
LM1A
PANEL
L=18'
VD=0.25%100-4600AF
500AT
3P
125AF
100AT
3P
100AF
70AT
3P
125AF
100AT
3P
125AF
125AT
3P
A
INV
L=10'
VD=0.08%20-320A
3P
400AF
400AT
3P
M SCE METER
UG
SCE
MAINSWITCHBOARD 'MSB-A'
1000A, 480/277V, 3 ⌀, 4W
100AF
50AT
3P
225AF
225AT
3P
1200AF
1000AT
3P
UTILITY
TRANSFORMER
L=20'
VD=0.12%225-3L=10'
VD=0.18%500-41000-4 L=65'
VD=0.26%
TRANSFORMER 'T-A'
150KVA
480-208Y/120V
3Ø, 4W
L=22'
VD=0.11%400-3L=27'
VD=0.19%50-4 27.3kISC
x
14416 ISC
x
10.7k ISC
x
9.7k ISC
x
5.7k ISC
x
10.1k ISC
x
25.0kISC
x
14.2kISC
x
9.1kISC
x
LPS1
PANEL
L=340'
VD=2.29%200-4S+225AF
200AT
3P
4.6k ISC
x
100AF
100AT
3P
L=100'
VD=0.59%70-340
F
ELEV. CNTRL
LL1A
PANEL
L=24'
VD=0.27%50-4125AF
50AT
3P
7.7k ISC
x
E-1002
(TYP.)
E-1002
(TYP.)
PROVISION FOR
FUTURE PV
PROVISION FOR
FUTURE BATTERY
LCPA
20A
1P
20-2L=10'
VD=0.04%
(F) CB
E-1008
E-1009
BESS
FUTURE
40HP / 52 FLA
ELEVATOR 1
ST
LCPB
20A
1P 20-2
L=10'
VD=0.09%
100AS
70AF
3P
20A/3P
(VOLTAGE
SENSING)
eGauge
SPD
E-1010
GFI
E-1011
E-1011
3.6k ISC
x
9.1kISC
x
KEYNOTES
GENERAL NOTES
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
SINGLE LINE
DIAGRAM AND LOAD
FEEDER SCHEDULE
E5.01
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNTS
SINGLE LINE DIAGRAM 07
1.ALL EQUIPMENT TO BE SQUARE D OR EQUAL BY SIEMENS, CUTLER - HAMMER, G.E., OR RSC -SIERRA.
2.ALL ELECTRICAL EQUIPMENT SHALL BE PROVIDED WITH SPECIFIED AND
APPROPRIATE UL LISTING BASED ON THE ENVIRONMENT IN WHICH THE EQUIPMENT IS TO BE MOUNTED.
3.ALL ELECTRICAL EQUIPMENT SHALL BE PROVIDED WITH AND BRACED FOR
REQUIRED FAULT CURRENT RATINGS BASED ON THEIR VOLTAGE AND LOCATION WITHIN THE SYSTEM. SHOP DRAWINGS TO INCLUDE FAULT CURRENT RATINGS FOR ALL ELECTRICAL EQUIPMENT. ALL EQUIPMENT SHALL BE FULLY RATED, NO SERIES RATING SHALL BE ALLOWED.
4.ALL TERMINATIONS AND ENCLOSURES SHALL BE RATED FOR USE WITH 75 DEGREES CELSIUS CONDUCTORS.
5.ALL SERVICE ENTRANCE EQUIPMENT/DISTRIBUTION
BOARDS/SWITCHBOARDS RATED AT 600A OR GREATER SHALL BE PROVIDED
WITH A SOLID STATE MAIN OVER -CURRENT PROTECTIVE DEVICE AND BUSSING RATED AT 100% OPERATION.6.ALL SWITCH/DISTRIBUTION BOARDS SHALL BE PROVIDED WITH:
TIN -PLATED ALUMINUM BUSSING WITH RECTANGULAR CROSS
SECTION. HORIZONTAL AND VERTICAL BUSSING SHALL BE FULL
LENGTH AND HAVE PROVISIONS FOR FUTURE EXTENSIONS WERE
APPLICABLE. ALL BUSSING SHALL HAVE A MINIMUM WITHSTAND
RATING EQUAL TO AVAILABLE FAULT CURRENT INDICATED ON THE AIC CALCULATION. ALL VERTICAL AND HORIZONTAL BUSSING SHALL
BE RATED AT FULL CAPACITY IN ALL SWITCHBOARD AND
DISTRIBUTION BOARD ASSEMBLIES. PROVIDE 100% NEUTRAL
BUSSING MINIMUM -UNLESS OTHERWISE NOTED. PROVIDE FULL
LENGTH GROUND BUSS, AND WHERE INDICATED ON PLANS,
ISOLATED GROUND BUSSING. PROVIDE REAR WIRE WAY IN ALL
SWITCHBOARD SECTIONS -UNLESS OTHERWISE NOTED OR
REQUIRED.
a.
LUGS SHALL BE SUITABLE FOR USE WITH BOTH COPPER AND
ALUMINUM CONDUCTORS AND 75 DEGREE CELSIUS AMPACITY
CONDUCTORS.
b.
PERMANENT PLACARDS(S) MARKED PER THE SPECIFICATIONS AND PER CEC -WHERE ADOPTED SECTIONS 225.37, 230.2(E), 690.56(B) & (C), 692.56, 700.8, 701.9, AND 702.8 DENOTING PRESENCE OF
ADDITIONAL SERVICES, PHOTOVOLTAIC SYSTEMS, FUEL CELLS,
EMERGENCY OR STAND -BY POWER SOURCES, ETC. AS APPLICABLE. c.
7.CONTRACTOR SHALL PROVIDE SWITCHBOARD SHOP DRAWINGS TO SERVING UTILITY COMPANY PRIOR TO FABRICATION OF EQUIPMENT.
CONTRACTOR SHALL SECURE CONFIRMATION PROPOSED SWITCHBOARD COMPLIES WITH ELECTRICAL UTILITY COMPANY REGULATIONS.
8.ELECTRICAL EQUIPMENT SUBMITTALS SHALL BE ACCOMPANIED BY A 1/4" = 1'-0" SCALED DRAWING WHICH REFERENCES ALL ELECTRICAL EQUIPMENT ROOMS AND EQUIPMENT. DRAWING SHALL CLEARLY IDENTIFY ADEQUATE
SPACE IS PROVIDED IN ELECTRICAL ROOMS TO ACCOMMODATE THE
INSTALLATION OF ELECTRICAL EQUIPMENT WHILE MAINTAINING ALL REQUIRED CODE CLEARANCES. ALL SUBMITTALS NOT ACCOMPANIED BY SCALED DRAWING WILL BE REJECTED AS INCOMPLETE.
9.EC SHALL CONDUCT, WITH ASSISTANCE OF SWITCHGEAR MANUFACTURER,
AN ELECTRICAL HAZARD ANALYSIS CONSISTING OF AN ARC FLASH, SHORT
CIRCUIT, AND COORDINATION STUDY TO DETERMINE APPROPRIATE LEVELS OF PERSONNEL PROTECTIVE EQUIPMENT (PPE) AS REQUIRED BY NFPA 70E AND IEEE STD 1584, AND TO ENSURE PROPER COORDINATION (INCLUDING
GROUND FAULT COORDINATION) EXISTS BETWEEN ALL OVER -CURRENT PROTECTIVE DEVICES SHOWN ON SINGLE -LINE DIAGRAM. ADDITIONALLY:
STUDY SHALL INCLUDE ALL PORTIONS OF ELECTRICAL SINGLE -LINE DIAGRAM. NORMAL SYSTEM CONNECTIONS AND THOSE THAT RESULT
IN MAXIMUM FAULT CONDITION SHALL BE ADEQUATELY COVERED IN THE STUDY. PERFORM STUDY WITH THE AID OF A COMPUTER
PROGRAM, SKM CAPTOR, OR EQUAL. STUDY SHALL IDENTIFY
SELECTIVE COORDINATION SUCH THAT DEVICE CLOSEST TO FAULT WILL TRIP FIRST. GROUND FAULT PORTION OF THE STUDY SHALL
DEMONSTRATE COORDINATION OF MAIN BREAKER AND ANY FEEDER
GROUND FAULT DEVICES WITH DOWNSTREAM CIRCUIT BREAKERS
30A AND LESS.
a.
EC SHALL BE RESPONSIBLE TO RECOMMEND SETTINGS OF ALL
DEVICES AND TO NCLUDE GROUND FAULT SETTINGS NECESSARY TO ACHIEVE SYSTEM COORDINATION. CONTRACTOR SHALL FIELD
ADJUST DEVICES ACCORDINGLY UTILIZING A QUALIFIED
MANUFACTURER'S REPRESENTATIVE.
b.
DURING THE CONSTRUCTION PHASE OF THE PROJECT ALL GROUND FAULT RELAYS SHALL BE SET AT SHORTEST AVAILABLE TIME DELAY. c.
RESULT OF COORDINATION STUDY SHALL BE SUBMITTED AS PART OF
OVERALL SWITCHGEAR SUBMITTAL AND SHALL INCLUDE PROTECTIVE
DEVICE TIME VERSUS CURRENT COORDINATION CURVES, GROUPING
APPROPRIATE DEVICES TOGETHER, TABULATIONS OF RELAY AND
CIRCUIT BREAKER TRIP SETTINGS, FUSE SELECTION, AND
COMMENTARY REGARDING SAME.
d.
A GROUND FAULT SYSTEM TEST SHALL BE CONDUCTED BY AN
INDEPENDENT TESTING AGENCY PER CEC -230.95(C). GROUND FAULT SYSTEM TEST SHALL BE PERFORMED IN PRESENCE OF LOCAL AHJ.
VERIFICATION OF DEVICE SETTINGS PER THE COORDINATION STUDY SHALL BE PERFORMED BY SAME INDEPENDENT TESTING AGENCY.
GROUND FAULT TEST RESULTS SHALL BE DELIVERED TO ENGINEER OF RECORD.
e.
PERFORM ARC FLASH ANALYSIS TO DETERMINE FALSH BOUNDARY,
FLASH HAZARD CATEGORY, PPE REQUIREMENTS, AND MINIMUM ARC RATING (CAL/SQUARE CM). ABOVE INFORMATION SHALL BE
INDICATED AT EACH ARC FLASH SOURCE ON A CEC COMPLIANT ARC FLASH HAZARD LABEL(S) AS MANUFACTURED BY BRADY.
f.
10.GROUND ALL ELECTRICAL EQUIPMENT, BRANCH CIRCUITS, FEEDERS, PANEL AND DISTRIBUTION BOARDS, ELECTRICAL SERVICES, ETC. PER ADOPTED CEC ARTICLE 250.
11.FEEDER SPECIFICATIONS ARE BASED ON USE OF COPPER CONDUCTORS
AND SHALL BE PROVIDED WITH A CODE SIZED COPPER GROUNDING CONDUCTOR. 12.ALL MAIN SWITCHBOARDS, PANELBOARDS, DISTRIBUTION BOARDS, ETC SHALL BE PROVIDED WITH A COPPER BUSS RATED AT SPECIFIED AMPACITY.
ALL SWITCHBOARDS AND DISTRIBUTION BOARDS SHALL ALIGN IN FRONT.
ALL PANELBOARDS SHALL BE PROVIDED WITH BOLT-ON BREAKERS,
DEADFRONT COVERS WITH LOCKABLE DOORS, FACTORY INSTALLED MAIN
CIRCUIT BREAKERS (IF APPLICABLE), AND PANEL DIRECTORY PER THESE DOCUMENTS.13.TRANSIENT VOLTAGE SURGE PROTECTION SHALL BE PROVIDED IN ALL MAIN
SWITCHGEAR AND DISTRIBUTION BOARD UNLESS OTHERWISE NOTED OR IDENTIFIED ON DRAWINGS. COORDINATE WITH LOCAL UTILITY COMPANY.
14.ALL PANELBOARDS INSTALLED IN GARAGES OR AREAS COMPLYING WITH ARTICLE 500, 511, AND/OR 514 SHALL BE INSTALLED 18'' ABOVE FLOOR LINE
TO BOTTOM OF PANEL AND SHALL BE IN MULTIPLE PANELS AS REQUIRED WITH TOP MOST BREAKER NO HIGHER THAN 6'-7'' A.F.F. PER ARTICLE 380.
15.ALL ELECTRICAL EQUIPMENT (I.E. SWITCHGEAR, TRANSFORMERS, DISTRIBUTION BOARDS, PANELBOARDS, DISCONNECT SWITCHES, ETC.)
SHALL BE PROVIDED WITH A PHENOLIC NAMEPLATE WITH ENGRAVED WHITE LETTERS REFERENCING FOLLOWING INFORMATION:
LINE 1 -"EQUIPMENT NAME"
LINE 2 -"FED FROM ..."
LINE 3 -"VOLTAGE, AMPACITY, PHASE"
LINE 4 -"DATE INSTALLED"
NAMEPLATES SHALL BE SIZED BASED ON FOLLOWING:
SWITCHBOARDS, DISTRIBUTION BOARDS, TRANSFORMERS:
* LINE 1 = 1/2'' LETTERS, LINES 2, 3, & 4 = 1/4'' LETTERS
PANELBOARDS, MOTOR CONTROL CENTERS, DISCONNECTS,
STARTERS, ETC:
* LINE 1 = 3/8'' LETTERS, LINES 2, 3, & 4 = 1/4'' LETTERS NAMEPLATE COLORS SHALL BE AS FOLLOWS:
BLACK = NORMAL POWER
RED = LIFE SAFETY/EMERGENCY POWER
BLUE = STANDBY POWER
GREEN = INVERTOR POWER
ALL NAMEPLATES SHALL BE FASTENED WITH A MINIMUM OF TWO (2) MACHINE SCREWS. NO SELF ADHESIVE NAMEPLATES ARE ALLOWED.
16.ELECTRICAL DESIGN COMPUTES VOLTAGE DROP BASED ON FEEDER LENGTHS REFERENCED ON SINGLE -LINE DIAGRAM. EC TO NOTIFY ENGINEER
OF RECORD IN EVENT FIELD CONDITIONS CAUSE A SUBSTANTIAL INCREASE IN OVERALL FEEDER LENGTH.
17.ANY FLOOR -STANDING ELECTRICAL EQUIPMENT (I.E. INVERTERS,
DISTRIBUTION BOARDS, SWITCHBOARDS, ATS SWITCHES, MOTOR CONTROL CENTERS, ETC.) WHICH ARE MOUNTED AT/BELOW GRADE AND/OR
SUSCEPTIBLE TO WATER DAMAGE SHALL BE MOUNTED ON A MINIMUM 4" HIGH HOUSEKEEPING PAD WHICH EXTENDS 4" BEYOND EQUIPMENT IN ALL DIRECTIONS.18.ALL MOTOR RELATED CIRCUITS ARE TO BE PROVIDED WITH PROTECTIVE RELAYS FOR PHASE FAILURE AND UNDER -VOLTAGE.
19.ELECTRICAL CONTRACTOR TO INCLUDE IN BID ALL ASSOCIATED COSTS FOR
THIRD PARTY TESTING OF ELECTRICAL EQUIPMENT, GROUND FAULT, CONDUCTORS, ETC..
9. NOT ALL SIZES USED.
AS...
8. FEEDERS WITH AN AMPACITY > 400A SHALL BE PROVIDED WITH A SPARE CONDUIT OF EQUIVALENT SIZE
7. FEEDERS CONNECTED TO AN EMERGENCY INVERTER OR PV SHALL BE RATED AT 90 DEG. C.
HAVE OVERSIZED NEUTRAL (200% MIN.)
6. FEEDERS CONNECTED TO THE SECONDARY OF A K-4 OR HIGHER XFMR SHALL
5. NOMINAL AMPACITIES GREATER THAN 100 AMPS ARE FOR 75 DEG. C TERMINALS.
4. "S" INDICATES A FEEDER COMING FROM A SEPARATELY DERIVED SYSTEM.
3. CONDUIT SIZES CALLED OUT ON PLANS SUPERSEDE THIS SCHEDULE.
2. A "+" IN FEEDER TAGS SHOWN ON PLANS INDICATES A FEEDER UPSIZED DUE TO VOLTAGE DROP.
CONDUCTORS WITH THHN/THWN INSULATION.
1. CONDUCTORS AND CONDUITS SHOWN IN THIS SCHEDULE ARE BASED ON COPPER
FEEDER SIZING NOTES
4000-4 11 4"(4)500 500 4000-3 11 4" (3)500 500
3000-4 8 4" (4)500 400 3000-3 8 4" (3)500 400
2500-4S 7 4" (4)500 250 ------ --- ------
2500-4 7 4" (4)500 350 2500-3 7 4" (3)500 350
2000-4 6 4" (4)500 250 2000-3 5 4" (3)500 250
1600-4S 5 4" (4)400 4/0 ------ --- ------
1600-4 5 4" (4)400 4/0 1600-3 4 3" (3)400 4/0
1200-4 4 4" (4)350 3/0 1200-3 4 3" (3)350 3/0
1000-4S 3 4" (4)500 3/0 ------ --- ------
1000-4 3 4" (4)500 2/0 1000-3 3 4" (3)500 2/0
800-4S 3 3" (4)300 3/0 ------ --- ------
800-4 3 3" (4)300 1/0 800-3 3 3" (3)300 1/0
750-4 2 4" (4)500 1/0 750-3 2 4" (3)500 1/0
650-4 2 4" (4)400 1/0 650-3 2 3" (3)400 1/0
600-4 2 3" (4)350 1 600-3 2 3" (3)350 1
500-4S 2 3" (4)250 2/0 ------ --- ------
500-4 2 3" (4)250 2 500-3 2 2-1/2" (3)250 2
450-4 2 2-1/2" (4)4/0 2 450-3 2 2-1/2" (3)4/0 2
400-4S 2 2-1/2" (4)3/0 1/0 ------ --- ------
400-4 2 2-1/2" (4)3/0 2 400-3 2 2" (3)3/0 2
350-4 1 4" (4)500 2 350-3 1 4" (3)500 2
300-4 1 3" (4)350 4 300-3 1 3" (3)350 4
250-4 1 3" (4)250 4 250-3 1 2-1/2" (3)250 4
225-4S 1 2-1/2" (4)4/0 2
225-4 1 2-1/2" (4)4/0 4 225-3 1 2-1/2" (3)4/0 4
200-4S+1 3" (4)350 2
200-4 1 2-1/2" (4)3/0 6 200-3 1 2" (3)3/0 6
175-4 1 2" (4)2/0 6 175-3 1 2" (3)2/0 6
150-4S 1 2-1/2" (4)350 6 ------ --- ------
150-4 1 2" (4)1/0 6 150-3 1 2" (3)1/0 6
125-4 1 2" (4)1 6 125-3 1 1-1/2" (3)1 6
110-4 1 1-1/2" (4)2 6 110-3 1 1-1/2" (3)2 6
100-4S+1 1-1/2" (4)1 6 ------ --- ------
100-4S 1 2" (4)4/0 4 ------ --- ------
100-4 1 1-1/2" (4)2 8 100-3 1 1-1/2" (3)2 8
90-4 1 1-1/2" (4)2 8 90-3 1 1-1/2" (3)2 8
80-4 1 1-1/2" (4)2 8 80-3 1 1-1/2" (3)2 8
70-4 1 1-1/2" (4)4 8 70-3 1 1-1/2" (3)4 8
60-4 1 1-1/2" (4)4 10 60-3 1 1-1/2" (3)4 10
50-4S 1 1" (4)1 6 ------ --- ------
50-4 1 1" (4)6 10 50-3 1 1" (3)6 10
40-4 1 1" (4)8 10 40-3 1 3/4" (3)8 10
30-4 1 3/4"(4)10 10 30-3 1 3/4" (3)10 10
20-4 1 3/4"(4)12 12 20-3 1 3/4" (3)12 12
15-4 1 3/4"(4)12 12 15-3 1 3/4" (3)12 12
------ --- ------20-2 1 3/4" (2)12 12
------ --- ------15-2S 1 3/4" (2)6 10
# SETS SIZE Φ & N GND # SETS SIZE Φ GND
MARK
(AMPACITY)
CONDUITS CONDUCTORS PER SET MARK
(AMPACITY)
CONDUITS CONDUCTORS PER SET
COPPER FEEDER SCHEDULE
ITEM DESCRIPTION
E-1002 PROVIDE SCHNEIDER ELECTRIC EM4900 OR ABB RGM45OOQ MULTI-CIRCUIT POWER METER WHERE SHOWN.
E-1008 SIZE OF CIRCUIT BREAKER TO BE DETERMINED BASED ON FUTURE PV DESIGN. FRAME SIZE TO BE A MININUM OF 225A
E-1009 PROVIDE (1) 2" CONDUIT FROM MAIN SWITCHBOARD MSB-A TO PV INVERTER UP TO CONDUIT STUB OUT ON THE ROOF. REFER
ENLARGED PLAN E4.01 AND ROOF PLAN E2.03 FOR ROUTING
INFORMATION
E-1010 PROVIDE A DIRECT CONNECTION FROM 50A CIRCUIT BREAKER TO
PANEL HLA PROVISIONALLY UNTIL THE PERMANENT FEED THROUGH THE BESS IS ESTABLISHED AND COMMISSIONED. EC TO PROVIDE FEEDERS TO AND FROM BESS AS PART OF BASE BID.
E-1011 REFER TO MAIN SYSTEM GROUND BUS DETAIL 01/1-E7.01 FOR CONDUCTOR SIZING AND CONNECTION DETAILS.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
PANEL SCHEDULES
E5.11
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGGENERAL PANEL SCHEDULE NOTES:
WHERE PANEL IS INDICATED TO INCLUDE FEED THRU LUGS, PROVIDE FEED THROUGH LUGS AT THE OPPOSITE END OF THE PANELBOARD FROM THE PANELBOARD MAIN LUGS.
WHERE PANEL IS INDICATED TO INCLUDE DOUBLE LUGS, PROVIDE A DOUBLE LUG KIT AT THE SAME END OF THE PANELBOARD AS THE PANELBOARD MAIN LUGS.
WHERE PANEL IS INDICATED TO INCLUDE 200% NEUTRAL, PROVIDE PANELBOARDS UL LISTED AS HAVING NEUTRAL BUSSES RATED TO CARRY 200 PERCENT OF THE CURRENT CARRYING CAPACITY OF THE PHASE BUSSING. OTHERWISE, NEUTRAL BUSSING TO BE FULL SIZE AND RECTANGULAR.
WHERE PANEL IS INDICATED TO INCLUDE AN I/G BUS, PROVIDE PANELBOARDS WITH AN ISOLATED GROUND BUS, DRILLED AND TAPPED
FOR NUMBER OF ISOLATED GROUND CONDUCTORS SHOWN, AS WELL AS FOR ALL SPARES AND SPACES SHOWN ON THE PANELBOARD.
ALL CIRCUIT BREAKERS SHALL BE FULLY RATED.
WHERE PANEL IS INDICATED AS RECESSED OR FLUSH MOUNTED, PROVIDE SPARE CONDUITS STUBBED UP INTO THE ACCESSIBLE CEILING SPACE. PROVIDE ONE (1) 3/4" CONDUIT ONLY FOR EACH THREE (3) SPARES OR SPACES, MINIMUM OF TWO (2). EACH CONDUIT SHALL BE TAGGED, CAPPED AND MARKED FOR FUTURE USE.
ALL BUSSING SHALL BE COPPER.
ALL CIRCUIT BREAKERS USED TO SERVE MECHANICAL OR HEATING EQUIPMENT SHALL BE UL LISTED AND LABELED "HACR" FOR USE WITH THESE LOADS, WHERE REQUIRED.
ALL CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE AND SHALL BE SUITABLE FOR 75 DEGREE AMPACITY CONDUCTORS.
PANELS SHALL BE OF THE DEAD FRONT SAFETY TYPE. PANELS SHALL BE MINIMUM 20" WIDE AND 5 3/4" DEEP UNLESS OTHERWISE NOTED ON PLAN.
COORDINATE WITH APPLICABLE TRADE TO INSURE RECESSED MOUNTED PANELBOARDS WILL SEAT FLUSH IN THE WALLS PROVIDED.
PANEL TRIMS SHALL HAVE CONCEALED DOORS AND FASTENERS WITH FLUSH TYPE COMBINATION LOCK AND CATCH, TWO MILLED TYPE KEYS SUPPLIED WITH EACH PANEL. ALL LOCKS SHALL BE KEYED ALIKE AND EACH DOOR SHALL HAVE A PLASTIC COVERED DIRECTORY FRAME WITH A TYPED IDENTIFICATION CARD OF ALL CIRCUIT AND PANEL NUMBERS FOR BRANCH CIRCUIT PANELBOARDS.
SPECIFIC PANEL SCHEDULE NOTES:
"A" PROVIDE LOCK -ON DEVICE
"B" PROVIDE LOCK -OFF DEVICE
"C" PROVIDE SHUNT TRIP DEVICE
"D" PROVIDE GFCI TYPE DEVICE.
"E" PROVIDE A RED CIRCUIT FIRE ALARM BREAKER. SEE SHEET FA0.03, KEYNOTE #6.
"F" PROVIDE A NEW BREAKER TO MATCH THE EXISTING IN PANEL. "G" PROVIDE BREAKER INTERLOCK WITH ADJACENT BREAKER.
BREAKER INTERLOCK GROUPING SHALL BE BY BRANCH
CIRCUIT GROUP (i.e. MULTIPLE CIRCUITS ON A COMMON
YOKE NEC 210.4(B) FURNITURE SYSTEM NEC 605.7)
"H" PROVIDE HACR BREAKER
"J" EXISTING BREAKER WITH NEW LOAD
UPON PROJECT COMPLETION, CONTRACTOR SHALL INSTALL TYPED AS -BUILT PANEL DIRECTORIES IN EACH PANEL WITHIN THE MFGR - PROVIDED DIRECTORY HOLDER. DIRECTORIES SHALL CONSIST OF LOAD DESCRIPTION AND CIRCUIT NUMBER FOR EACH CIRCUIT BASED ON AS -BUILT PANEL SCHEDULES. HANDWRITTEN DIRECTORIES ARE UNACCEPTABLE. LOCAL AHJ MAY REQUIRE COPIES OF ENGINEERED PANEL SCHEDULES BE PLACED IN PANEL DIRECTORIES. E.C. TO VERIFY REQUIREMENTS PRIOR TO BID AND INCLUDE ALL
COSTS REQUIRED FOR LARGER -THAN -STANDARD CUSTOM PANEL DIRECTORY HOLDERS TO ACCOMMODATE COPIES OF ENGINEERED PANEL SCHEDULES.
PANELBOARDS SHALL BE MANUFACTURED BY G.E., CUTLER -HAMMER, SIEMENS, OR SQUARE "D".
PROVIDE SHOP DRAWING SUBMITTAL PER THE ELECTRICAL SPECIFICATION SUBMITTAL REQUIREMENTS FOR EACH PANEL DEPICTING CONFORMANCE WITH THE ABOVE NOTES AND SCHEDULES.
NOTES
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
11. 12.
13. 14.
LL1ALM1ADB-A
HLA
LP1BLP1AHMA
MSB-A
INVA
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 43212 VA 125.00% 54015 VA
RECEPTACLE LOADS 31916 VA 65.67% 20958 VA Total Est. Demand...378 A HVAC 180903 VA 100.00% 180903 VA Total Conn. Current:372 A NON CONTINUOUS LOADS 20180 VA 100.00% 20180 VA Total Est. Demand:314257 VA LIGHTING LOADS 15008 VA 125.00% 18760 VA Total Conn. Load:309624 VA CONTINUOUS LOADS 3600 VA 125.00% 4500 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:372 A
Total Conn. Load:309624 VA
20 19
18 17
16 15
14 13
12 11
10 9
8 7
6 5 eGauge (VOLTAGE SENSING)3 20 A 20 A 500 VA
4 HLA 3 100 A 50 A 14053 VA
3 HMA 3 400 A 400 A 169263 VA
2 ELEVATOR 1 3 100 A 100 A 43212 VA
1 T-A 3 225 A 225 A 82730 VA
CKT Circuit Description # of Poles Frame Size Trip Rating Load Remarks Notes:
Enclosure:NEMA 1 MCB Rating:1000 A
Mounting:FLOOR Wires:4 Mains Rating:1200 A
Supply From:Phases:3 Mains Type:MCB
Location:Space 15 Volts:277/480V A.I.C. Rating:42 kAIC
Switchboard: MSB-A
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 0 VA 0.00%0 VA
RECEPTACLE LOADS 0 VA 0.00%0 VA Total Est. Demand...204 A HVAC 164163 VA 100.00% 164163 VA Total Conn. Current:204 A NON CONTINUOUS LOADS 0 VA 0.00%0 VA Total Est. Demand:169263 VA LIGHTING LOADS 0 VA 0.00%0 VA Total Conn. Load:169263 VA CONTINUOUS LOADS 0 VA 0.00%0 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:204 A 204 A 204 A
Total Load:56421 VA 56421 VA 56421 VA
41 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 42
39 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 40
37 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 38
35 ---- --1700 VA 0 VA 1 20 A Spare 36
33 ---- --1700 VA 0 VA 1 20 A Spare 34
31 EWH-1 20 A 3 1700 VA 0 VA 1 20 A Spare 32
29 ---- --4650 VA 6430 VA -- -- --30
27 ---- --4650 VA 6430 VA -- -- --28
25 VRF-2 MODULE 2 20 A 3 4650 VA 6430 VA 3 30 A VRF-3 26 23 ---- --7280 VA 6535 VA -- -- --24
21 ---- --7280 VA 6535 VA -- -- --22
19 VRF-1 MODULE 3 40 A 3 7280 VA 6535 VA 3 35 A VRF-2 MODULE 1 20 17 ------7280 VA 7280 VA -- -- --18
15 ------7280 VA 7280 VA -- -- --16
13 VRF-1 MODULE 1 40 A 3 7280 VA 7280 VA 3 40 A VRF-1 MODULE 2 14 11 ------10526... 4000 VA -- -- --12
9 ------10526... 4000 VA -- -- --10
7 AHU-1 50 A 3 10526... 4000 VA 3 20 A AHU-2 8
5 ------370 VA 370 VA -- -- --6
3 ------370 VA 370 VA -- -- --4
1 CF-1 20 A 3 370 VA 370 VA 3 20 A HVAC 2
CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes:
Enclosure:NEMA 1 MCB Rating:400 A
Mounting:SURFACE Wires:4 Mains Rating:400 A
Supply From:MSB-A Phases:3 Mains Type:MCB
Location:Space 15 Volts:277/480V A.I.C. Rating:42 kAIC
Branch Panel: HMA
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 0 VA 0.00%0 VA
RECEPTACLE LOADS 0 VA 0.00%0 VA Total Est. Demand...21 A HVAC 0 VA 0.00%0 VA Total Conn. Current:17 A
NON CONTINUOUS LOADS 0 VA 0.00%0 VA Total Est. Demand:17534 VA LIGHTING LOADS 13920 VA 125.00% 17400 VA Total Conn. Load:14053 VA CONTINUOUS LOADS 0 VA 0.00%0 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:17 A 25 A 11 A
Total Load:4502 VA 6621 VA 2930 VA
41 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 42
39 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 40
37 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 38
35 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 36
33 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 34
31 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 32
29 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 30
27 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 28
25 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 26
23 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 24
21 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 22
19 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 20
17 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 18
15 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 16
13 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 14
11 Spare 20 A 1 0 VA 0 VA -- -- --12
9 SITE LGT (LCPA)20 A 1 726 VA 0 VA -- -- --10
7 LIGHTING PATIO 20 A 1 560 VA 2732 VA 3 20 A INV-A 8
5 LIGHTING FLOOR 2 20 A 1 2720 VA 210 VA 1 20 A LIGHTING WALL FLOOR 2 6 3 LIGHTING FLOOR 2 20 A 1 3400 VA 2495 VA 1 20 A LIGHTING FLOOR 1 4 1 LIGHTING LOADS 20 A 1 720 VA 490 VA 1 20 A LIGHTING HALLWAY FLOOR 1 2 CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes:
Enclosure:NEMA 1 MCB Rating:50 A
Mounting:SURFACE Wires:4 Mains Rating:125 A
Supply From:MSB-A Phases:3 Mains Type:MCB
Location:Space 15 Volts:277/480V A.I.C. Rating:22 kAIC
Branch Panel: HLA
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 0 VA 0.00%0 VA
RECEPTACLE LOADS 31916 VA 65.67% 20958 VA Total Est. Demand...203 A HVAC 16740 VA 100.00% 16740 VA Total Conn. Current:230 A NON CONTINUOUS LOADS 20180 VA 100.00% 20180 VA Total Est. Demand:73014 VA LIGHTING LOADS 1088 VA 125.00% 1360 VA Total Conn. Load:82730 VA CONTINUOUS LOADS 3600 VA 125.00% 4500 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:230 A
Total Conn. Load:82730 VA
20 19
18 17
16 15
14 13
12 11
10 9
8 7 Spare 1 125 A 100 A 0 VA
6 LPS1 3 225 A 200 A 33482 VA
5 LL1A 3 125 A 50 A 4680 VA
4 LM1A 3 125 A 100 A 4260 VA
3 LP2A 3 100 A 70 A 6334 VA
2 LP1B 3 125 A 100 A 9725 VA
1 LP1A 3 125 A 125 A 24618 VA
CKT Circuit Description # of Poles Frame Size Trip Rating Load Remarks Notes:
Enclosure:NEMA 1 MCB Rating:500 A
Mounting:FLOOR Wires:4 Mains Rating:600 A
Supply From:T-A Phases:3 Mains Type:MCB
Location:Space 15 Volts:120/208V A.I.C. Rating:22 kAIC
Switchboard: DB-A
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 0 VA 0.00%0 VA
RECEPTACLE LOADS 19607 VA 75.50% 14804 VA Total Est. Demand...55 A HVAC 0 VA 0.00%0 VA Total Conn. Current:68 A
NON CONTINUOUS LOADS 480 VA 100.00% 480 VA Total Est. Demand:19819 VA LIGHTING LOADS 0 VA 0.00%0 VA Total Conn. Load:24618 VA CONTINUOUS LOADS 0 VA 0.00%0 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:80 A 71 A 58 A
Total Load:9373 VA 8327 VA 6927 VA
41 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 42
39 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 40
37 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 38
35 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 36
33 CIRC. PUMP & REC 20 A 1 300 VA 0 VA 1 20 A Spare 34
31 LV FLUSH & LAVATORY RM 106 20 A 1 680 VA 0 VA 1 20 A Spare 32 29 LV FLUSH & LAVATORY RM 107 20 A 1 680 VA 0 VA 1 20 A Spare 30 27 REC. RR 20 A 1 720 VA 0 VA 1 20 A Spare 28
25 RECEPTACLE LOADS Space 38 20 A 1 900 VA 0 VA 1 20 A Spare 26 23 REC. MECH. RM. & ETP 20 A 1 540 VA 0 VA 1 20 A Spare 24 21 REC. RM 101 & 114 20 A 1 720 VA 900 VA 1 20 A DRINKING FOUNTAIN EXHBIT 100 22 19 REC. REFRIGERATOR STOR. 101 20 A 1 1200 VA 900 VA 1 20 A REC. CONVENIENCE EXHBIT 100 20 17 REC. COFFEE MAKER STOR. 101 20 A 1 1200 VA 720 VA 1 20 A REC. FLOOR EXHIBIT 100 18 15 REC. MICROWAVE STORAGE 101 20 A 1 1200 VA 720 VA 1 20 A REC. FLOOR EXHIBIT 100 16 13 REC. PRINTER STORAGE 101 20 A 1 1200 VA 1080 VA 1 20 A REC. FLOOR EXHIBIT 100 14 11 REC. RM 101 20 A 1 900 VA 1080 VA 1 20 A REC. FLOOR EXHIBIT 100 12 9 REC. RM 102 20 A 1 720 VA 1080 VA 1 20 A REC. FLOOR EXHIBIT 100 10 7 REC. ELEV. RM & ETP 20 A 1 360 VA 1080 VA 1 20 A REC. FLOOR EXHIBIT 100 8 5 REC. RM 102 20 A 1 900 VA 1080 VA 1 20 A REC. FLOOR EXHIBIT 100 6 3 FURNITURE WHIP RM 102 20 A 1 1080 VA 1080 VA 1 20 A REC. FLOOR EXHIBIT 100 4 1 FURNITURE WHIP RM 102 20 A 1 1080 VA 1056 VA 1 20 A REC. EXHIBIT 100 2 CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes:
Enclosure:NEMA 1 MCB Rating:125 A
Mounting:SURFACE Wires:4 Mains Rating:125 A
Supply From:DB-A Phases:3 Mains Type:MCB
Location:Space 15 Volts:120/208V A.I.C. Rating:14 kAIC
Branch Panel: LP1A
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 0 VA 0.00%0 VA
RECEPTACLE LOADS 1980 VA 100.00% 1980 VA Total Est. Demand...27 A HVAC 0 VA 0.00%0 VA Total Conn. Current:27 A
NON CONTINUOUS LOADS 3100 VA 100.00% 3100 VA Total Est. Demand:9736 VA LIGHTING LOADS 45 VA 125.00%56 VA Total Conn. Load:9725 VA CONTINUOUS LOADS 0 VA 0.00%0 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:34 A 28 A 21 A
Total Load:4000 VA 3245 VA 2480 VA
41 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 42
39 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 40
37 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 38
35 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 36
33 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 34
31 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 32
29 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 30
27 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 28
25 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 26
23 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 24
21 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 22
19 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 20
17 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 18
15 RISER BELL 20 A 1 500 VA 0 VA 1 20 A Spare 16
13 FA POWER SUPPLY 20 A 1 500 VA 0 VA 1 20 A Spare 14
11 REC. ELEC RM.20 A 1 180 VA 900 VA 1 20 A GATE OPENER 12 9 ELEV. PIT 20 A 1 225 VA 900 VA 1 20 A GATE OPENER 10
7 ELEVATOR CART LIGHT DISC. 20 A 1 900 VA 1200...1 20 A PROJECTOR EXHIBIT 8 5 REC. EXTERIOR 20 A 1 900 VA 500 VA 1 20 A PROJECTOR SCREEN EXHIBIT 6 3 REC. EXTERIOR 20 A 1 720 VA 900 VA 1 20 A GATE OPENER 4 1 POWER DOOR 20 A 1 500 VA 900 VA 1 20 A GATE OPENER 2
CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes:
Enclosure:NEMA 1 MCB Rating:100 A
Mounting:SURFACE Wires:4 Mains Rating:125 A
Supply From:DB-A Phases:3 Mains Type:MCB
Location:Space 15 Volts:120/208V A.I.C. Rating:14 kAIC
Branch Panel: LP1B
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 0 VA 0.00%0 VA
RECEPTACLE LOADS 0 VA 0.00%0 VA Total Est. Demand...12 A HVAC 4260 VA 100.00% 4260 VA Total Conn. Current:12 A
NON CONTINUOUS LOADS 0 VA 0.00%0 VA Total Est. Demand:4260 VA LIGHTING LOADS 0 VA 0.00%0 VA Total Conn. Load:4260 VA
CONTINUOUS LOADS 0 VA 0.00%0 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:18 A 6 A 14 A
Total Load:2040 VA 660 VA 1560 VA
41 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 42
39 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 40
37 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 38
35 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 36
33 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 34
31 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 32
29 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 30
27 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 28
25 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 26
23 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 24
21 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 22
19 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 20
17 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 18
15 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 16
13 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 14
11 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 12
9 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 10
7 ---- --0 VA 1380...-- -- --8
5 FS-1 20 A 2 180 VA 1380... 2 20 A EF-1 6
3 ---- --500 VA 160 VA -- -- --4
1 VFC-1 & VFC-2 20 A 2 500 VA 160 VA 2 20 A VFC-4 & VFC-4 2 CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes:
Enclosure:NEMA 1 MCB Rating:100 A
Mounting:SURFACE Wires:4 Mains Rating:125 A
Supply From:DB-A Phases:3 Mains Type:MCB
Location:Space 15 Volts:120/208V A.I.C. Rating:14 kAIC
Branch Panel: LM1A
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 0 VA 0.00%0 VA
RECEPTACLE LOADS 1080 VA 100.00% 1080 VA Total Est. Demand...15 A HVAC 0 VA 0.00%0 VA Total Conn. Current:13 A
NON CONTINUOUS LOADS 0 VA 0.00%0 VA Total Est. Demand:5580 VA LIGHTING LOADS 0 VA 0.00%0 VA Total Conn. Load:4680 VA
CONTINUOUS LOADS 3600 VA 125.00% 4500 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:18 A 11 A 11 A
Total Load:2160 VA 1260 VA 1260 VA
41 0 VA 1 20 A Spare 42
39 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 40
37 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 38
35 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 36
33 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 34
31 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 32
29 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 30
27 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 28
25 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 26
23 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 24
21 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 22
19 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 20
17 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 18
15 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 16
13 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 14
11 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 12
9 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 10
7 Spare 20 A 1 0 VA 900 VA -- -- --8
5 REC. IDF RM 105 20 A 1 360 VA 900 VA 2 30 A REC. IDF RM 105 6 3 REC. IDF RM 105 20 A 1 360 VA 900 VA -- -- --4
1 REC. IDF RM 105 20 A 1 360 VA 900 VA 2 30 A REC. IDF RM 105 2 CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes:
Enclosure:NEMA 1 MCB Rating:50 A
Mounting:SURFACE Wires:4 Mains Rating:125 A
Supply From:DB-A Phases:3 Mains Type:MCB
Location:Space 15 Volts:120/208V A.I.C. Rating:10 kAIC
Branch Panel: LL1A
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 0 VA 0.00%0 VA
RECEPTACLE LOADS 0 VA 0.00%0 VA Total Est. Demand...4 A HVAC 0 VA 0.00%0 VA Total Conn. Current:3 A
NON CONTINUOUS LOADS 0 VA 0.00%0 VA Total Est. Demand:3412 VA LIGHTING LOADS 2717 VA 125.00% 3397 VA Total Conn. Load:2732 VA CONTINUOUS LOADS 0 VA 0.00%0 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:3 A
Total Conn. Load:2732 VA
20 19
18 17
16 15
14 13
12 11
10 9
8 7
6 5
4 EMERGENCY LTG FLOOR 2 1 20 A 20 A 1592 VA
3 EMERGENCY LTG FLOOR 1 1 20 A 20 A 927 VA
2 EM SITE LGT (LCPA)1 20 A 20 A 198 VA
1 EXIT SIGN 1 20 A 20 A 15 VA
CKT Circuit Description # of Poles Frame Size Trip Rating Load Remarks Notes:
Enclosure:NEMA 1 MCB Rating:20 A
Mounting:FLOOR Wires:4 Mains Rating:20 A
Supply From:HLA Phases:3 Mains Type:MCB
Location:Space 15 Volts:277/480V A.I.C. Rating:14 kAIC
INVERTER: INV-A
A,E
A,E
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
PANEL SCHEDULES
E5.12
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGGENERAL PANEL SCHEDULE NOTES:
WHERE PANEL IS INDICATED TO INCLUDE FEED THRU LUGS, PROVIDE FEED THROUGH LUGS AT THE OPPOSITE END OF THE PANELBOARD FROM THE PANELBOARD MAIN LUGS.
WHERE PANEL IS INDICATED TO INCLUDE DOUBLE LUGS, PROVIDE A DOUBLE LUG KIT AT THE SAME END OF THE PANELBOARD AS THE PANELBOARD MAIN LUGS.
WHERE PANEL IS INDICATED TO INCLUDE 200% NEUTRAL, PROVIDE PANELBOARDS UL LISTED AS HAVING NEUTRAL BUSSES RATED TO CARRY 200 PERCENT OF THE CURRENT CARRYING CAPACITY OF THE PHASE BUSSING. OTHERWISE, NEUTRAL BUSSING TO BE FULL SIZE AND RECTANGULAR.
WHERE PANEL IS INDICATED TO INCLUDE AN I/G BUS, PROVIDE PANELBOARDS WITH AN ISOLATED GROUND BUS, DRILLED AND TAPPED
FOR NUMBER OF ISOLATED GROUND CONDUCTORS SHOWN, AS WELL AS FOR ALL SPARES AND SPACES SHOWN ON THE PANELBOARD.
ALL CIRCUIT BREAKERS SHALL BE FULLY RATED.
WHERE PANEL IS INDICATED AS RECESSED OR FLUSH MOUNTED, PROVIDE SPARE CONDUITS STUBBED UP INTO THE ACCESSIBLE CEILING SPACE. PROVIDE ONE (1) 3/4" CONDUIT ONLY FOR EACH THREE (3) SPARES OR SPACES, MINIMUM OF TWO (2). EACH CONDUIT SHALL BE TAGGED, CAPPED AND MARKED FOR FUTURE USE.
ALL BUSSING SHALL BE COPPER.
ALL CIRCUIT BREAKERS USED TO SERVE MECHANICAL OR HEATING EQUIPMENT SHALL BE UL LISTED AND LABELED "HACR" FOR USE WITH THESE LOADS, WHERE REQUIRED.
ALL CIRCUIT BREAKERS SHALL BE BOLT -ON TYPE AND SHALL BE SUITABLE FOR 75 DEGREE AMPACITY CONDUCTORS.
PANELS SHALL BE OF THE DEAD FRONT SAFETY TYPE. PANELS SHALL BE MINIMUM 20" WIDE AND 5 3/4" DEEP UNLESS OTHERWISE NOTED ON PLAN.
COORDINATE WITH APPLICABLE TRADE TO INSURE RECESSED MOUNTED PANELBOARDS WILL SEAT FLUSH IN THE WALLS PROVIDED.
PANEL TRIMS SHALL HAVE CONCEALED DOORS AND FASTENERS WITH FLUSH TYPE COMBINATION LOCK AND CATCH, TWO MILLED TYPE KEYS SUPPLIED WITH EACH PANEL. ALL LOCKS SHALL BE KEYED ALIKE AND EACH DOOR SHALL HAVE A PLASTIC COVERED DIRECTORY FRAME WITH A TYPED IDENTIFICATION CARD OF ALL CIRCUIT AND PANEL NUMBERS FOR BRANCH CIRCUIT PANELBOARDS.
SPECIFIC PANEL SCHEDULE NOTES:
"A" PROVIDE LOCK -ON DEVICE
"B" PROVIDE LOCK -OFF DEVICE
"C" PROVIDE SHUNT TRIP DEVICE
"D" PROVIDE GFCI TYPE DEVICE.
"E" PROVIDE A RED CIRCUIT FIRE ALARM BREAKER. SEE SHEET FA0.03, KEYNOTE #6.
"F" PROVIDE A NEW BREAKER TO MATCH THE EXISTING IN PANEL. "G" PROVIDE BREAKER INTERLOCK WITH ADJACENT BREAKER.
BREAKER INTERLOCK GROUPING SHALL BE BY BRANCH
CIRCUIT GROUP (i.e. MULTIPLE CIRCUITS ON A COMMON
YOKE NEC 210.4(B) FURNITURE SYSTEM NEC 605.7)
"H" PROVIDE HACR BREAKER
"J" EXISTING BREAKER WITH NEW LOAD
UPON PROJECT COMPLETION, CONTRACTOR SHALL INSTALL TYPED AS -BUILT PANEL DIRECTORIES IN EACH PANEL WITHIN THE MFGR - PROVIDED DIRECTORY HOLDER. DIRECTORIES SHALL CONSIST OF LOAD DESCRIPTION AND CIRCUIT NUMBER FOR EACH CIRCUIT BASED ON AS -BUILT PANEL SCHEDULES. HANDWRITTEN DIRECTORIES ARE UNACCEPTABLE. LOCAL AHJ MAY REQUIRE COPIES OF ENGINEERED PANEL SCHEDULES BE PLACED IN PANEL DIRECTORIES. E.C. TO VERIFY REQUIREMENTS PRIOR TO BID AND INCLUDE ALL
COSTS REQUIRED FOR LARGER -THAN -STANDARD CUSTOM PANEL DIRECTORY HOLDERS TO ACCOMMODATE COPIES OF ENGINEERED PANEL SCHEDULES.
PANELBOARDS SHALL BE MANUFACTURED BY G.E., CUTLER -HAMMER, SIEMENS, OR SQUARE "D".
PROVIDE SHOP DRAWING SUBMITTAL PER THE ELECTRICAL SPECIFICATION SUBMITTAL REQUIREMENTS FOR EACH PANEL DEPICTING CONFORMANCE WITH THE ABOVE NOTES AND SCHEDULES.
NOTES
1. 2.
3. 4.
5. 6.
7. 8.
9. 10.
11. 12.
13. 14.
LPS1LP2A
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 0 VA 0.00%0 VA
RECEPTACLE LOADS 3060 VA 100.00% 3060 VA Total Est. Demand...94 A HVAC 12480 VA 100.00% 12480 VA Total Conn. Current:93 A NON CONTINUOUS LOADS 16600 VA 100.00% 16600 VA Total Est. Demand:33743 VA LIGHTING LOADS 1043 VA 125.00% 1304 VA Total Conn. Load:33482 VA CONTINUOUS LOADS 0 VA 0.00%0 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:139 A 63 A 82 A
Total Load:16425 VA 7506 VA 9551 VA
53 EM LGT. VIA INVERTER (LCPB) 20 A 1 331 VA 0 VA 1 20 A Spare 54 51 EXTERIOR LGT (LCPB)20 A 1 186 VA 0 VA 1 20 A Spare 52 49 INTERIOR LGT 20 A 1 625 VA 0 VA 1 20 A Spare 50
47 48
45 46
43 44
41 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 42
39 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 40
37 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 38
35 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 36
33 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 34
31 ---- --4150... 4150...-- -- --32
29 EWH-2 RM 112 50 A 2 4150... 4150... 2 50 A EWH-2 RM 113 30 27 ---- --3120... 3120...-- -- --28
25 CU-1 40 A 2 3120... 3120...2 40 A CU-2 26
23 24
21 22
19 20
17 Space -- 1 ---- 1 -- Space 18
15 Space -- 1 ----1 -- Space 16
13 Space -- 1 ----1 -- Space 14
11 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 12
9 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 10
7 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 8
5 REC. STEM CLASS RM 112 20 A 1 720 VA 200 VA 1 20 A LCPB 6 3 REC. STEM CLASS RM 112 20 A 1 540 VA 540 VA 1 20 A REC. STEM CLASS RM 113 4 1 REC. EXTERIOR 20 A 1 720 VA 540 VA 1 20 A REC. STEM CLASS RM 113 2 CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes:
Enclosure:NEMA 3R MCB Rating:200 A
Mounting:SURFACE Wires:4 Mains Rating:225 A
Supply From:DB-A Phases:3 Mains Type:MCB
Location:Volts:120/208V A.I.C. Rating:10 kAIC
Branch Panel: LPS1
Notes:
Other 0 VA 0.00%0 VA
LARGEST MOTOR LOADS 0 VA 0.00%0 VA
RECEPTACLE LOADS 6334 VA 100.00% 6334 VA Total Est. Demand...18 A HVAC 0 VA 0.00%0 VA Total Conn. Current:18 A
NON CONTINUOUS LOADS 0 VA 0.00%0 VA Total Est. Demand:6334 VA LIGHTING LOADS 0 VA 0.00%0 VA Total Conn. Load:6334 VA
CONTINUOUS LOADS 0 VA 0.00%0 VA
Load Classification Connected Load Demand Factor Estimated...Panel Totals Legend:
Total Amps:28 A 19 A 9 A
Total Load:3167 VA 2105 VA 1080 VA
41 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 42
39 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 40
37 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 38
35 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 36
33 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 34
31 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 32
29 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 30
27 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 28
25 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 26
23 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 24
21 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 22
19 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 20
17 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 18
15 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 16
13 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 14
11 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 12
9 Spare 20 A 1 0 VA 0 VA 1 20 A Spare 10
7 REC. FLOOR MEZZANINE 20 A 1 1080... 0 VA 1 20 A Spare 8 5 REC. FLOOR MEZZANINE 20 A 1 1080... 0 VA 1 20 A Spare 6 3 REC. FLOOR MEZZANINE 20 A 1 1080... 1080...1 20 A REC. CONVENIENCE MEZZ. 4 1 REC. FLOOR MEZZANINE 20 A 1 1080... 1080...1 20 A REC. CONVENIENCE MEZZ. 2 CKT Circuit Description Trip P A B C P Trip Circuit Description CKT Notes:
Enclosure:NEMA 1 MCB Rating:70 A
Mounting:RECESSED Wires:4 Mains Rating:125 A
Supply From:DB-A Phases:3 Mains Type:MAIN CB
Location:Space 35 Volts:120/208V A.I.C. Rating:10 kAIC
Branch Panel: LP2A
SPLIT BUS
SPLIT BUS
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
MECHANICAL AND
PLUMBING
SCHEDULES
E5.21
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING26 - AIR HANDLING UNIT WITH RETURN FAN SCHEDULE
TAG SERVICE LOCATION
ELECTRICAL
DISCONNECT CONDUIT/WIREVOLTAGEPHASEFLAMCAMOCP
AHU-1 HIGH VOLUME SPACE MECH. ROOM 103 460 V 3 38.0 A 39.9 A 45 A 60AS/45AF/3P 1"C. 3#6 + 1#8 GND.
AHU-2 MEZZANINE MECH. ROOM 103 460 V 3 14.4 A 15.6 A 20 A 30AS/20AF/3P 3/4'C. 3#12 + 1#12 GND 26 - FAN SCHEDULE (EXHAUST)
TAG SERVICE LOCATION
MOTOR DATA ELECTRICAL
CONDUIT/WIRE DISCONNECTHPRPM VOLTAGE PHASE
EF-1 GENERAL EXHAUST MECH. ROOM 103 2 1650 208 V 3 3/4'C. 3#12 + 1#12 GND 30AS/20AF/3P 26 - HVLS CEILING FANS
TAG LOCATION
ELECTRICAL
DISCONNECT CONDUIT/WIREVOLTAGE PHASE
HP
(WATTS)AMPS
CF-1 EXHIBIT SPACE 460 V 3 1,100W 4 A 30AS/20AF/3P 3/4'C. 3#12 + 1#12 GND CF-2 EXHIBIT SPACE 460 V 3 1,100W 4 A 30AS/20AF/3P 3/4'C. 3#12 + 1#12 GND 26 - SPLIT SYSTEM (MINI) INDOOR UNIT SCHEDULE
TAG
POWER FROM
OUTDOOR
UNIT
ELECTRICAL
DISCONNECTVOLTAGE PHASE
FC-1 YES 208 V 1 2 POLES MOTOR RATED TOGGLE SWITCH
FC-2 YES 208 V 1 2 POLES MOTOR RATED TOGGLE SWITCH
26 - SPLIT SYSTEM (MINI) OUTDOOR UNIT SCHEDULE
TAG SERVICE LOCATION
ELECTRICAL
DISCONNECT CONDUIT/WIREVOLTAGE PHASE MCA MOCP
CU-1 FC-1 BUILDING EXTERIOR @ GRADE 208 V 1 30 A 40 A 60AS/40AF/2P NEMA 3R 1"C. 3#8 + 1#10 GND.
CU-2 FC-2 BUILDING EXTERIOR @ GRADE 208 V 1 30 A 40 A 60AS/40AF/2P NEMA 3R 1"C. 3#8 + 1#10 GND. 26 - VARIABLE REFRIGERANT CONDENSING UNIT SCHEDULE
TAG SERVICE VOLT. PHASE
MODULE 1 MODULE 2 MODULE 3 MODULE 1 MODULE 2 MODULE 3
MCA MOCP MCA MOCP MCA MOCP DISCONNECT CONDUIT/WIRE DISCONNECT CONDUIT/WIRE DISCONNECT CONDUIT/WIRE VRF-1 AHU-1 460 V 3 27.4 40 27.4 40 27.4 35 60AS/40AF/3P NEMA 3R 1"C. 3#8 + 1#10 GND. 60AS/40AF/3P NEMA 3R 1"C. 3#8 + 1#10 GND. 60AS/35AF/3P NEMA 3R 1"C. 3#8 + 1#8 GND.
VRF-2 AHU-2 460 V 3 24.6 35 17.5 20 - - 60AS/35AF/3P NEMA 3R 1"C. 3#10 + 1#10 GND. 30AS/20AF/3P NEMA 3R 1"C. 3#12 + 1#12 GND. -- VRF-3 VFC-1, VFC-2, VFC-3, VFC-4 460 V 3 24.2 30 - - - - 30AS/30AF/3P NEMA 3R 1"C. 3#10 + 1#10 GND. ---- 26 - VARIABLE REFRIGERANT FAN COIL UNIT SCHEDULE
TAG SERVICE
ELECTRICAL
DISCONNECT CONDUIT/WIREVOLT. PHASE MCA MOCP
VFC-1 EMR 230 1 0.3 15 2 POLES MOTOR RATED TOGGLE SWITCH 3/4'C. 2#12 + 1#12 GND VFC-2 STAFF OFFICE / BREAK ROOM 230 1 3.4 15 2 POLES MOTOR RATED TOGGLE SWITCH 3/4'C. 2#12 + 1#12 GND VFC-3 IDF 230 1 0.6 15 2 POLES MOTOR RATED TOGGLE SWITCH 3/4'C. 2#12 + 1#12 GND VFC-4 ELECTRICAL ROOM 230 1 0.6 15 2 POLES MOTOR RATED TOGGLE SWITCH 3/4'C. 2#12 + 1#12 GND 26 - VRF FLOW SELECTOR UNIT SCHEDULE1
TAG QUANTITY LOCATION
ELECTRICAL
DISCONNECT CONDUIT/WIREVOLT PHASE MCA MOCP
FS-1 1 STAFF OFFICE / BREAK ROOM 208 1 0.75 15 A 2 POLES MOTOR RATED TOGGLE SWITCH 3/4'C. 2#12 + 1#12 GND 26- ELECTRIC WATER HEATER SCHEDULE
ITEM MANUFACTURER LOCATION ELECTRICAL
DISCONNECT CONDUIT/WIREVOLTAGE AMPS PHASE kW
EWH-1 AO SMITH JANITOR'S ROOM 109 480 V 10.4 A 3 5 30AS/20AF/3P NEMA 1 1"C. 3#12 + 1#12 GND.
EWH-2 EEMAX STEM 111 & 112 208 V 40.0 A 1 8.3 60AS/50AF/2P NEMA 1 1"C. 2#6 + 1#6 GND.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
LIGHTING CONTROL
DIAGRAMS AND
DETAILS
E6.01
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
3-BUTTON SINGLE ZONE (TYP.)
FUNCTION ASSIGNMENTENGRAVING
ON/OFF
RAISE
LOWER
CONTROLLED ZONE(S) FADE ON/OFF (3 SECOND FADE RATE)
CONTROLLED ZONE(S) RAISE INCREMENTALLY
CONTROLLED ZONE(S) LOWER INCREMENTALLY
SZ-3B
ON/OFF
ON/OFF
FUNCTION ASSIGNMENTENGRAVING
ON/OFF
RAISE
LOWER
ZONE (a) FADE ON/OFF (3 SECOND FADE RATE)
ZONE (a) RAISE INCREMENTALLY
ZONE (a) LOWER INCREMENTALLY
MZ-6B
6-BUTTON 2-ZONE (TYP.)
1 2
1 ON/OFF
RAISE
LOWER
ZONE (b) FADE ON/OFF (3 SECOND FADE RATE)
ZONE (b) RAISE INCREMENTALLY
ZONE (b) LOWER INCREMENTALLY
2 FUNCTION ASSIGNMENTENGRAVING
ZONE
ZONE
ON
ZONE
(a)
(b)
(c)
MASTER ON 100% (ALL ZONES)
MZ4-8B
1 2
ON
3 8-BUTTON 4-ZONE (TYP.)
1 2
3 4
ON
OFF
ZONE (d)4
OFF MASTER OFF (ALL ZONES)OFF
RAISE SELECTED SCENE RAISES INCREMENTALLY
LOWER SELECTED SCENE LOWERS INCREMENTALLY
FUNCTION ASSIGNMENTENGRAVING
ON
OFF
ZONE
MASTER ON 100% (ALL ZONES - 3 SECOND FADE RATE)
MASTER OFF (ALL ZONES - 3 SECOND FADE RATE)
G
TOUCH SCREEN 16-ZONE (1ST FLOOR - DOORS/ MEZZANINE)
ALL ON
ZONE
ZONE
ZONE
ALL OFF
SURFACE MOUNTED DOWNLIGHTS
SURFACE MOUNTED DOWNLIGHTS
VESTIBULE DOWNLIGHT
EXHIBIT HIGHBAYS
MEZZANINE HIGHBAYS ZONE
COLUMN DOWNLIGHTS ZONE
(a)
(b)
(c)
(d)
(e)
(f)
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Job Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
408-780-7200 Office
408-780-7201 Fax
60 South Market Street,
Suite 150
San Jose, California 95113
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SPACE SHUTTLE EXHIBIT ANDEDUCATION BUILDINGCOLUMBIA WAYDOWNEY, CA 902423055401
LIGHTING CONTROL
DIAGRAMS AND
DETAILS
E6.02
08/01/2025
N.T.S.
LIGHTING CONTROL PROGRAMMING/ENGRAVING -nLIGHT nPODMA 3
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
1 # * cu., 3/4"C. TO METAL
UNDERGROUND WATER PIPE AND OR
INTERIOR METAL WATER PIPE WITHIN 5'
OF POINT OF ENTRANCE INTO THE
BUILDING PER ART. 250.52(A)(1).
FINISHED FLOOR
MAIN BONDING JUMPER SHALL
BE SIZED AS FOLLOWS:
GROUNDING ELECTRODE CONDUCTOR SHALL
BE SIZED AS FOLLOWS:
2,000A
0-200A
201-400A
OVER 401A
2,500A
4,000A
3,000A
SERVICE SIZE
SERVICE SIZE
0-1,000A
1,600A
1,200A
#300KCMIL
#4
#3/0
#1/0
G.E.C. SIZE
#500KCMIL
#600KCMIL
#500KCMIL
M.B.J. SIZE
#250KCMIL
#3/0
#4/0
0-200 FT.
OVER 200 FT.#3/0
#1/0
TELECOMMUNICATIONS GROUND CONDUCTOR
MINIMUM SIZE SHALL BE BASED ON DISTANCE
BETWEEN TELECOMMUNICATIONS ROOM AND
SYSTEM GROUNDING BUS BAR AS FOLLOWS:
1 # *** cu., 3/4"C. TO
TELECOMMUNICATIONS ROOM
BACKBOARDS & GROUNDING
BUS BARS. IF PROVIDED IN
PROJECT DRAWINGS, SEE
TELECOM PATHWAYS &
GROUNDING RISER FOR
ADDITIONAL REQUIREMENTS.
1 # ** cu. TO GROUNDED
CONDUCTOR PER ART.
250.102. PROTECTED WITH
CODE-SIZED EMT, IMC, OR
RIGID CONDUIT AS
CONDITIONS DICTATE.
1 # * cu., 3/4"C. TO EFFECTIVELY
GROUNDED METAL FRAME OF
THE BLDG. PER ART. 250.52(A)(2).
(1) MINIMUM 20 FT. LENGTH OF #4
MINIMUM/ 1# * BARE COPPER
ENCASED IN MINIMUM 2" OF
CONCRETE ALL AROUND PER ART.
250.52(A)(3).
WHEN A GROUND RING IS REQUIRED
ELSEWHERE IN THESE DRAWINGS,
PROVIDE BARE cu CONDUCTOR
CONNECTION EQUAL IN SIZE TO
GROUND RING CONDUCTOR BUT
NOT LESS THAN #2 BARE cu., PER
ART. 250.52(A)(4).
1 #6 cu., 1/2"C. TO ELECTRODE
PER ART. 250.52(A)(5), (A)(6),
(A)(7) & 250.53 WHERE NONE
OF THE ELECTRODES IN ART.
250.52 (A)(1), (A)(2), (A)(3) &
(A)(4) ARE AVAILABLE.
PROVIDE CONNECTION OF
GROUNDING CONDUCTORS
BONDING JUMPERS PER ART.250.8
(TYPICAL) USING 2-HOLE
CONNECTORS.
1 # *** cu., 3/4"C. TO UTILITY CO.
TELEPHONE/CATV BACKBOARD.
(3) SPARE DRILLED
CONNECTION POINTS
TO GROUND BUS LOCATED
WITHIN BUILDING SERVICE
SWITCHGEAR.
PROVIDE PERMANENT TAG TO
IDENTIFY EACH CONDUCTOR.
1/4"x3"x LENGTH AS REQUIRED.
COPPER GROUND BUS
OUTSIDE SWITCHBOARD,
DRILLED AND TAPPED AS
REQUIRED. PROVIDE
PHENOLIC LABEL INDICATING
"MAIN ELECTRICAL SERVICE
GROUND". SEE ELECTRICAL
SPECIFICATIONS FOR MORE
INFORMATION.
PROVIDE BONDING WITH 1# ** cu., 1 1/4"C.
TO NEAREST METAL,WATER PIPE (HOT,
COLD, SPRINKLER, SEWER, BUILDING
MOUNTED - INTERIOR OREXTERIOR ETC),
UNINTENTIONALLY UNGROUNDED
BUILDING STEEL, GAS PIPE, HVAC
DUCTS IN THE BUILDING PER ART.
250.104 (A), (B), & (C)
1#6 CU TO RAISED FLOOR PEDESTALS
PER NEC ART. 645.15. SEE DETAIL 10
THIS SHEET FOR ADDITIONAL
GROUNDING INFORMATION AND
REQUIREMENTS.
***
**
*
LPA
SWITCHBOARD
INSULATED GROUNDING
BUSHING SIZE AS REQUIRED
CONDUIT NIPPLE (TYPICAL)
SWITCHBOARD FOUNDATION
AND HOUSEKEEPING PAD
FOOTING AS REQUIRED
BY STRUCTURE
CONDUIT PER PLAN
FINISH FLOOR
CONDUIT COUPLING
INSTALL FLUSH WITH
FOUNDATION (TYPICAL)
GROUNDING BUS
TIE ALL CONDUIT STUB WITH
GROUND WIRE SIZE PER NEC
AND BOND TO GROUNDING BUS
4"
LPA
WALL OR FLOOR
APPLY SEALANT ON BOTH SIDES FOR
WALL APPLICATION
CONDUIT
GENERAL ELECTRICAL
SILICONE/PENSIL 100 SEALANT OR
EQUAL THICKNESS AS REQUIRED.
4" MINERAL WOOL, SYSTEM # 238
LPA
1-2 HOUR FIRE RATED
GYPSUM WALL BOARD
1/4"(6MM) MINIMUM
DIAMETER BEAD OF
INTUMESCENT PUTTY
METAL PIPE OR
CONDUIT
STEEL STUD
NOTES FOR THIS DETAIL:
1. THE SPACE BETWEEN THE PENETRATING ITEM AND WALL
BOARD MUST ACCOMMODATE AT LEAST ONE WRAP (1/4")
OF INTUMESCENT WRAP STRIP.
2. IF THE ANNULAR SPACE IS LESS THAN 1/2", ONE WRAP OF
INTUMESCENT WRAP STRIP IS REQUIRED. IF THE ANNULAR
SPACE IS 1/2" OR GREATER, FILL WITH ADDITIONAL WRAPS
OF FS-195 WRAP STRIP UNTIL THE ANNULAR SPACE IS
LESS THEN 1/4". WRAP STRIPS MAY BE FRICTION FIT INTO
OPENING, SECURED WITH FOIL TAPE OR 16 GAUGE STEEL
TIE WIRE.
3. SLIDE THE WRAP STRIP INTO THE OPENING, LEAVING A
MAX. 3/4" EXPOSED WRAP BEYOND THE WALL SURFACE.
4. SEAL THE WRAP/STRIP EDGES AND SEAMS WITH A 1/4"
MINIMUM BEAD OF INTUMESCENT PUTTY.
5. INSTALL FIRESTOP ON BOTH SIDES OF THE WALL.
6. THESE RECOMMENDATIONS ARE BASED ON PRODUCT
PERFORMANCE PER ASTM-E814 (UL 1479) FIRE TEST AND
UL THROUGH-PENETRATION FIRESTOP SYSTEM # WL1002.
LPA
72" MAX FLEX LENGTH
MIN #6 AWG INSULATED
GROUNDING CONDUCTOR
PROVIDE % SLACK
CONDUIT PENDANT
SUPPORTER SECURED
DIRECTLY TO BUILDING
STRUCTURE
CONDUIT
BUILDING STRUCTURE SEISMIC JOINT
LPA
FINISHED FLOOR
OVER OBSTRUCTIONMOUNTING HEIGHT
FINISHED FLOOR 44" MAX. - FORWARD REACHOVER AN OBSTRUCTIONTOP OF DEVICE
TO BOTTOM OF DEVICE
TOP OF DEVICE
48" MAX.15" MIN.24" MAX
34" MAX46" MAX.- SIDE APPROACH
LPA
(TELE/DATA) BACKFILL WITH
SAND OR BACKFILL MATERIAL
FREE OF LARGE ROCKS, PAVING
MATERIALS, CINDERS, LARGE OR
SHARPLY ANGULAR
SUBSTANCES, OR CORROSIVE
MATERIALS.
(POWER) ENCASE IN CONCRETE.
PROVIDE 2-SACK SLURRY
ENCASEMENT.
3" BASE (SAND OR TWO-SACK
CONCRETE SLURRY ENCASEMENT)
PAVING BASE
UNDISTURBED EARTH
WARNING TAPE
SELECTED BACKFILL FREE OF
LARGE DEBRIS AND COMPACTED
TO MEET 95% MAXIMUM DENSITY
TYPICAL ELECTRICAL OR SIGNAL
CONDUIT. FOR QUANTITY,
DISTRIBUTION AND SIZES, SEE
RESPECTIVE SITE PLANS.
ASPHALT OR CONCRETE PAVING
SEE SITE AND/OR CIVIL PLANS FOR
LOCATIONS.
BACKFILL TO MATCH EXISTING
GRADE AT NON-PAVED AREAS
24" MIN. U.O.N.DIMENSION AS REQUIRED12" DIMENSION AS REQUIRED3" 2" 2" 3" "3" 2" 2" 2" 3" LPA
W.P. DUPLEX GROUND FAULT INTERRUPTER
RECEPTACLE IN W.P. BOX WITH UL LISTED
IN-USE COVER PER SPECIFICATIONS.
PROVIDE 20A SNAP SWITCH IN LIEU OF
RECEPTACLE WHEN CONNECTING TO
SIGNAGE.
6" SQ. x 3/8" THICK BASE PLATE (GALV) WITH
(4) 3/8" DIA. THRU BOLTS TO 6" SQ. x 3/8"
PLATE ON UNDERSIDE OF DECK. PROVIDE
1" EDGE DISTANCE TYPICAL AT PLATE.
RGS THREADED PIPE CAP,
SIZED AS REQUIRED (TYP).
RGS PIPE SUPPORT(S),
SIZED AS REQUIRED (TYP).
NOTE: OFFSET CONDUIT A MINIMUM OF 12"
FROM THE CONDUIT SUPPORT SYSTEM SO
THAT CONDUIT FLASHING CLEARS OTHER
STRUCTURES - OTHER FLASHING. FIELD VERIFY
REQUIRED DISTANCE. CONDUIT, WHILE
DEPICTED DIRECTLY IN FRONT OF RECEPTACLE
FOR EASE OF REPRESENTATION, SHALL BE
OFFSET TO THE RIGHT OR LEFT SIDE OF THE
RECEPTACLE.
ROOF MATERIAL ON
INTERIOR OF PARAPET WALL
6" BELOW TOP OF SCREEN OR
PARAPET WALL. VERIFY WITH
ARCHITECT PRIOR TO ROUGH-IN.
BOX HOLDER, SIZED AS REQUIRED
(ARLINGTON OR EQUAL).
LIQUID TIGHT CONDUIT -
36" OR LESS IN LENGTHLEAD ROOF FLASHING UON PER
SPECIFICATIONS, ARCHITECTURAL PLANS
AND SMACNA STANDARDS. SEAL CONDUIT
AT FLASHING AS REQUIRED (TYP).
RGS CONDUIT EXTENDING A MINIMUM OF 12 INCHES
ABOVE THE ROOF TO ALLOW FLASHING OF PENETRATION
- USE OF EMT FOR ROOF PENETRATION IS NOT ALLOWED.
2 CONDUIT SUPPORTS REQUIRED PER PENETRATION.
PROVIDE UNISTRUT AS NECESSARY TO SPAN BETWEEN
ROOF SUPPORT MEMBERS. COORDINATE ALL
ATTACHMENTS WITH ARCHITECT PRIOR TO ROUGH-IN.
RUN CONDUIT
AS REQUIRED LPA
PULL BOX NOTES:
1. ALL BOXES SHALL BE SET ON A GRAVEL BASE WITH \" DIAMETER GRAVEL. DEPTHS PER DETAIL.
2. ALL INCIDENTAL CONCRETE SHALL BE REMOVED FROM BOXES.
3. PROVIDE WATERTIGHT SPLICES AND CAPS FOR POWER CONDUCTORS.
4. PROVIDE SEALING GEL IN ALL CONDUITS (BOTH W/ CONDUCTORS AND IN EMPTY SPARE CONDUITS.) GEL SHALL BE INSERTED IN THE CONDUIT TO A DEPTH OF 6" AND FLUSH W/ THE END OF THE CONDUIT.
THE GEL SHALL BE MANUFACTURED BY 3M #4442 RE-ENTERABLE ENCAPSULANT.
5. PROVIDE IDENTIFYING TAGS ON ALL POWER AND COMMUNICATION CONDUCTORS IN PULL-BOXES.
6. PULLBOX SHALL BE SIZED PER N.E.C. REQUIREMENTS.
7. SEE PULL-BOX/MAN-HOLE GROUNDING DETAIL FOR ADDITIONAL GROUNDING INFORMATION.
BASE
GRADESERVICE LOOP
DRAIN HOLE
COMPACTED SOIL
END BELL
FITTING
MAINTAIN 6" MIN FROM
DRIVEWAY EDGE AND MIN 4"
FROM CURB FINAL LOCATION
PER LANDSCAPE ARCHITECT.
EXTENSION QUANTITY PER
FINAL TRENCH DEPTH AND
CONDUIT ROW ARRANGEMENT.
ADJUST PULLBOX HEIGHT FOR
LID FLUSH WITH PAVED AREA
OR LID 1" ABOVE UNPAVED
AREA.
TRAFFIC COVER, STEEL
BOLT DOWN
IDENTIFY PER SYSTEM:
1. FIRE ALARM
2. LOW VOLTAGE
SYSTEM/SIGNAL
3. POWER
PULL BOX AS MANUFACTURED
BY BROOKS OR EQUAL, (SEE
PLANS FOR SIZE)
RUN CONDUIT THRU OPENINGS
WITH " SPACE.
SLOPE CONDUIT 4%
FOR DRAINAGE
COMPACTED PEA
GRAVEL
8"
12"
24" MIN
LPA
(1) -STAINLESS STEEL
DRAW BAND
PRE-MOLDED RUBBER PIPE
FLASHING
ROOF INSULATION
CONDUIT,
BY E.C.SEALANT (URETHANE)
ROOF DECK
TOP OF STEEL JOIST
NOTES:
1. CONDUIT SHALL BE SUPPORTED WITHIN 24 INCHES ABOVE AND BELOW ROOF.
2. VERIFY FINAL REQUIREMENTS WITH GENERAL CONTRACTOR (G.C.) AND ROOFING INSTALLER PRIOR TO INSTALLATION.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ELECTRICAL
DETAILS
E7.01
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN.T.S.
MAIN SYSTEM GROUND BUS -MSGB 01
N.T.S.
SWITCHBOARD STUB -UPS AND GROUNDING BOND 03
N.T.S.
FIRE -RATED POKETHRU DETAIL 12
N.T.S.
FIRESTOPPING FOR DRYWALL CONDUIT PENETRATION (PUTTY)17
1/2" = 1'-0"
CONDUIT SEISMIC EXPANSION JOINT CROSSING 18
12" = 1'-0"
ADA DEVICE MOUNTING 19
12" = 1'-0"
UNDERGROUND DUCTBANK SECTION (DIRECT BURIAL)09
N.T.S.
HOLIDAY / STAND ALONE / SIGN DISCONNECT SWITCH / RECEPTACLE MOUNTING DETAIL 20 12" = 1'-0"
PULL BOX 10
12" = 1'-0"
CONDUIT ROOF PENETRATION 04
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
POURED-IN-PLACE
CONCRETE OUTLET BOX
INTERIOR
FACEPLATE
CONDUIT(S) PER PLAN
CONCRETE
INTERIOR BARRIER BEHIND
INTERIOR FACEPLATE.
KEYED LOCK.
INTERIOR FACEPLATE
OPENING(S) PER PLANS.
MFGR - PROVIDED CORD
OPENINGS TO MAINTAIN RAIN-
TIGHT-WHILE IN USE RATING.
COMMUNICATIONS CONDUIT ROUTED
PER PLAN. IF ROUTING IS NOT SHOWN
ON PLAN, INCLUDE ALL COSTS IN BASE
BID TO ROUTE (1) 3/4"C.O. FROM EACH
DUAL SERVICE DEVICE TO NEAREST IDF
RACK.
SIDE VIEW FRONT VIEW
LPA
SSTYPICAL SCHEMATIC ELEVATOR ROOM DETAILS
TYPICAL SCHEMATIC ELEV. MACHINE ROOM.
SEE SINGLE LINE DIAGRAM
ELEVATOR SHUTDOWN WIRING DETAIL
ELEVATOR MACHINE ROOM.
ELEV. CONTROLLER
ELEV. MOTOR
SEE PLANS
SEE PLANS WP
WHERE REQUIRED BY UNIFORM FIRE CODE, UNIFORM BUILDING CODE AND/OR STATE/LOCAL SUPPLEMENTAL CODES, PROVIDE THE FOLLOWING:
TYPICAL SCHEMATIC ELEV. SHAFT
WP
WP
SEE PLANSS
S m
L.V. FIRE ALARM CONTROL DEVICE(S) FOR ELEVATOR BATTERY LOWERING DEVICE SHUNT MECHANISM.
FIRE ALARM CONTRACTOR TO PROVIDE SPEAKER AND FIREMAN'S PHONE JACK FOR EACH ELEVATOR TO BE INSTALLED BY ELEVATOR CONTRACTOR. SPEAKER AND JACK TO BE CUSTOM COLOR AND MATERIAL PER ARCHITECT.
PROVIDE CONDUIT(S) FROM THE HOISTWAY/MACHINE ROOM TO FIRE CONTROL ROOM AND AUTOMATIC TRANSFER SWITCHES. COORDINATE CONDUIT SIZE, ROUTING AND QUANTITY WITH G.C. AND ELEVATOR CONTRACTOR PRIOR TO BID.
FIRE ALARM CONTRACTOR TO PROVIDE FIREMAN'S PHONE JACK AT EACH LOBBY. JACK AND FACEPLATE TO BE PER ARCHITECTURAL DETAIL.
CONNECT TO EMERGENCY CIRCUIT.
L.V. FIRE ALARM CONTROL DEVICE FOR ALTERNATE FLOOR CAPTURE/RECALL FUNCTION.
PROVIDE EMERGENCY OR STANDBY 120V POWER, IF AVAILABLE ON PROJECT, TO SMOKE AND/OR FIRE DOOR.
CONNECT AS REQUIRED. PROVIDE ADDITIONAL WALL SWITCH J-BOX WITH CONDUIT/ CONDUCTORS TO CONTROL PANELS REQUIRED FOR SMOKE AND/OR FIRE DOOR RESET SWITCH. PROVIDE L.V. FIRE ALARM CONTROL AND MONITORING DEVICE(S) FOR SMOKE AND/OR FIRE DOOR. CONNECT TO ELEVATOR CONTROLLER(S) AS REQUIRED.
SEE ARCHITECTURAL PLANS FOR LOCATIONS AND QUANTITIES. COORDINATE EXACT LOCATIONS AND REQUIREMENTS WITH SMOKE AND/OR FIRE DOOR SUPPLIER AND ARCHITECT PRIOR TO ROUGH-IN.
W.P. SWITCH AND SURFACE-MOUNTED, WET LOCATION-LISTED, SINGLE 32W T8 FLUORESCENT FIXTURE WITH
MOLDED ACRYLIC LENS AND FIBERGLASS REINFORCED POLYESTER BODY TO BE LOCATED IN ELEVATOR PIT PER CODE REQUIREMENTS. PROVIDE REQUIRED QUANTITY OF FIXTURES NECESSARY TO MEET CODE MINIMUM LIGHT LEVELS. W.P. SWITCH TO BE LOCATED ADJACENT TO ELEVATOR PIT LADDER.
W.P. G.F.C.I. OUTLET TO BE LOCATED IN ELEVATOR PIT PER CODE AND MANUFACTURER REQUIREMENTS.
W.P. G.F.C.I. OUTLET TO BE LOCATED HALFWAY UP ELEVATOR SHAFT IF REQUIRED BY CODE OR MANUFACTURER REQUIREMENTS.
W.P. G.F.C.I. OUTLET TO BE LOCATED IN ELEVATOR MACHINE ROOM PER CODE AND MANUFACTURER'S REQUIREMENTS.
TELEPHONE OUTLET. COORDINATE MOUNTING LOCATION WITH ELEVATOR MANUFACTURER TO DETERMINE IF PHONE IS TO BE MOUNTED IN EITHER THE ELEVATOR SHAFT OR THE ELEVATOR MACHINE ROOM OR BOTH.
ROUTE (1) 3/4"C.O. FROM OUTLET TO NEAREST IDF ROOM OR TELEPHONE BACKBOARD WHICHEVER IS CLOSER.
ELEVATOR DISCONNECT/MOTOR START SWITCH. INTERCONNECT TO ELEVATOR MOTOR CONTROLLER(S). LOCATE AND LABEL DISCONNECT SWITCH(S) PER CODE REQUIREMENTS. SEE SINGLE LINE DIAGRAM FOR MORE INFORMATION/REQUIREMENTS. COORDINATE REQUIREMENTS WITH EQUIPMENT MANUFACTURER AND INSTALLATION GUIDES.
CONTRACTOR TO PROVIDE MOUNTING BACK BOXES FOR ELEVATOR CALL BUTTON AND ELEVATOR FLOOR LIGHT AT EACH FLOOR. COORDINATE MOUNTING LOCATION AND DIMENSIONS WITH ARCHITECTURAL ELEVATIONS.
L.V. SMOKE DETECTOR(S) TO BE LOCATED AT EACH ELEVATOR LOBBY/FLOOR FOR ELEVATOR CAPTURE/RECALL.
CONNECT TO ELEVATOR CONTROLLER(S) VIA FIRE ALARM CONTROL DEVICE(S) AS REQUIRED.
PROVIDE A 3P 30A LOCKABLE FUSED DISCONNECT SWITCH WITH NEUTRAL AND (2) 20A FUSES FOR CONNECTION
TO ELEVATOR CAB LIGHTING, CAB RECEPTACLE, CAB VENTILATION, AND/OR CAB AIR CONDITIONING/HEATING UNIT(S). INSTALL DISCONNECT AND BRANCH CIRCUITS PER NEC (CEC WHERE ADOPTED) ART 620.22 & 620-53.
SMOKE AND HEAT DETECTORS LOCATED IN ELEVATOR HOISTWAY ACCESSIBLE FROM OUTSIDE ELEVATOR SHAFT.
SEE ELEVATOR SHUTDOWN WIRING DETAIL. CONTRACTOR TO COORDINATE EXACT REQUIREMENTS WITH THE ARCHITECT AND THE FIRE ALARM DESIGN BUILD CONTRACTOR PRIOR TO ROUGH IN. SET HEAT DETECTORS 10 DEGREES LESS THAN SPRINKLER HEAD. INSTALLATION SHALL COMPLY WITH RULE 211.3b OF ASME A17.0 (CURRENT EDITION) AND ELEVATOR INSPECTOR REQUIREMENTS.
SMOKE AND HEAT DETECTORS LOCATED IN ELEVATOR MACHINE ROOM. SEE ELEVATOR SHUTDOWN WIRING DETAIL.
L.V. FIRE ALARM CONTROL DEVICE(S) FOR ELEVATOR CAPTURE/RECALL. CONNECT TO ELEVATOR CONTROLLER(S) AS REQUIRED.
PROVIDE LOCKABLE 30A FUSED SWITCH AND EXTEND CIRCUIT TO ELEVATOR GROUP CONTROLLER(S), IF REQUIRED. COORDINATE LOCATION AND FUSE SIZES (IF REQUIRED) WITH ELEVATOR CONTRACTOR PRIOR TO ROUGH IN.
PROVIDE 1/2" CONDUIT WITH REQUIRED CONDUCTORS FROM DISCONNECT SWITCH AUXILIARY CONTACTS TO ELEVATOR CONTROLLER. COORDINATE REQUIREMENTS WITH ELEVATOR CONTRACTOR AND G.C. PRIOR TO ROUGH-IN.
PROVIDE CONNECTION TO SUMP PUMP, AS REQUIRED.
ROOM LIGHT SWITCH TO BE WITHIN 18" OF DOOR. SEE LIGHTING PLANS FOR MORE INFORMATION.
ELEVATOR PLAN NOTES:ELEVATOR INSTALLATION REQUIREMENTS:
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE FURNISHING OF ALL MATERIAL, LABOR, EQUIPMENT, AND SERVICES, IN CONNECTION WITH THE INSTALLATION OF A COMPLETE AND FULLY FUNCTIONING AND CODE COMPLIANT INSTALLATION.
2. IT IS THE INTENT OF THE CONTRACT DOCUMENTS, WHICH ARE PRESENTED IN A DIAGRAMMATIC FORMAT, ARE TO PROVIDE
CONTRACTOR INFORMATION THAT SUPPLEMENTS AND ENHANCES THE GENERALLY ACCEPTED CONSTRUCTION MEANS,
METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES EMPLOYED IN CONNECTION WITH INSTALLATION OF THIS TYPE OF PRODUCT / SYSTEM.
3. THE CONTRACTOR SHALL ALSO INCORPORATE THE REQUIREMENTS OF THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND WARRANTY REQUIREMENTS AS PART OF THE REQUIREMENTS OF THE CONSTRUCTION DOCUMENTS. IN THE EVENT OF A
CONFLICT BETWEEN THE CONTRACT DOCUMENT REQUIREMENTS AND THE MANUFACTURERS INSTALLATION REQUIREMENTS,
THE MORE STRINGENT REQUIREMENTS SHALL APPLY - UNLESS THE MORE STRINGENT REQUIREMENT VOIDS APPLICABLE WARRANTIES OR VIOLATES THE REQUIREMENTS OF THE LOCAL AUTHORITY HAVING JURISDICTION. ANY SUCH CONFLICT SHALL IMMEDIATELY BE BROUGHT TO THE ATTENTION OF THE ENGINEER IN WRITING THROUGH THE FORMAL RFI PROCESS.
4. REFER TO THE ASSOCIATED SCHEDULES, SCHEMATICS, DRAWINGS, AND SPECIFICATIONS FOR DETAILED INFORMATION AND REQUIREMENTS ON THIS PRODUCT / SYSTEM.
5. THE CONTRACTOR SHALL COORDINATE AND VERIFY EXACT REQUIREMENTS WITH ELEVATOR DRAWINGS, SPECIFICATIONS AND THE ELEVATOR CONTRACTOR PRIOR TO ANY ROUGH IN.
ELEVATOR DISCONNECT
WITH DPDT AUXILIARY
CONTACTS. SEE MOTORIZED
EQUIP. SCHEDULE.
ELECTRICAL ROOM WHERE
ELEVATOR FEEDER OVER
CURRENT DEVICE EXISTS.
SHUNT TRIP BREAKER WITH
NORMALLY OPEN CONTACT.
SEE SINGLE LINE DIAGRAM.
N.O. MOMENTARY CONTACT
RELAY-ADJUST TIMING AS
REQUIRED. SEE FIRE ALARM
INFORMATION SHEET.
WP
SEE
MOTORIZED
EQUIPMENT
SCHEDULE
CIRCUIT
120 VOLT
TO FACP
(IF SPRINKLED)
ELEVATOR SHAFT.
ELEVATOR MACHINE ROOM.
MONITOR SHUNT TRIP CIRCUIT
ELEVATOR LOBBY WITH SMOKE
AND/OR FIRE DOOR(S) PER
ARCHITECTURAL PLANS.
CONNECT TO ELEVATOR
CONTROLLER FOR ELEVATOR
CAPTURE RECALL
CONNECT TO ELEVATOR
CONTROLLER FOR ALTERNATE
FLOOR ELEVATOR CAPTURE/
RECALL
CONNECT TO ELEVATOR
BATTERY POWER LOWERING
DEVICE SHUNT MECHANISM
SMOKE AND/OR FIRE DOOR
WITH NORMALLY OPEN
CONTACT. SEE SINGLE
ELECTRICAL ROOM WHERE
ELEVATOR FEEDER OVER
CURRENT DEVICE EXISTS.
SHUNT TRIP BREAKER WITH
NORMALLY OPEN CONTACT.
SEE SINGLE LINE DIAGRAM.
N.O. MOMENTARY CONTACT
RELAY-ADJUST TIMING AS
REQUIRED.
Zm
RCC
C
C
RC
Zm R
M
F
PH
M C R
PH
C
C
S
C
J
J J
J
F
M
F
1 2
3 4
5 6
7 8
9 10
11 12
13 14
15 16
17 18
19 20
21 22
23 21
4 9 14
6 16
11 22
13 6
19 5
2 3
15 18
10 1
1 1
723
8 20
5 17
12 1
1 LPA 7 " 11 " 4 " 6 "
CONCRETE
SLAB
ELECTRICAL
CONDUIT
ELECTRICAL
DEVICE
PVC
TRANSITION FROM PVC
TO COATED RIGIS
STEEL
GROUNDING ELECTRODE CONDUCTOR
SHALL BE SIZED AS FOLLOWS: SEE
RESPECTIVE SYSTEM/DEVICE
SCHEDULE FOR G.E.C. SIZE.
WHERE GROUNDED STRUCTURAL MEMBER OR
EFFECTIVE GROUNDED WATER PIPE IS
UNAVAILABLE ON THE PREMISES (*), PROVIDE 1 #
cu., "C. TO A CONCRETE-ENCASED ELECTRODE
WITH MIN OF 20 FT IN LENGTH OF MIN. #4 BARE
ENCASED IN MIN. 2" OF CONCRETE ALL AROUND,
OR A GROUND RING IN DIRECT CONTACT WITH
EARTH AT A DEPTH NOT LESS THAN 2\ FT. WITH 20
FT. LENGTH MIN OF #2 BARE COPPER,
WHICHEVER IS AVAILABLE, PER ART. 250.52(A) (3)
& (4).
WHERE NO EFFECTIVE GROUNDING
ELECTRODE (*) IS AVAILABLE PER ART. 250.50,
PROVIDE 1 # cu., ["C. TO OTHER LOCAL METAL
UNDERGROUND PIPING SYSTEMS AND TANKS,
OR ROD AND PIPE ELECTRODES WITH MIN. OF 8
FT. IN LENGTH AND SHALL BE INSTALLED PER
ART. 250.52(A)(5)(a) & (b), OR PLATE
ELECTRODES, WHICHEVER IS AVAILABLE, PER
ART 250.52 (A)(5), (A)(6) & (A)(7)
10' COPPER GROUND
ELECTRODE(S) W/ EXOTHERMIC
CONNECTION(S) TO GROUND
CONDUCTOR. PROVIDE FIBER
GLASS INSPECTION WELL(S).
QUANTITY AS REQUIRED TO
ACHIEVE CODE-REQUIRED
RESISTANCE VALUES.
NEUTRAL BUS WITHIN
EQUIPMENT.
WHEN SEPARATELY DERIVED
SYSTEM IS A UPS, CPC, PDU OR
TRANSFORMER LOCATED IN
INFORMATION TECHNOLOGY ROOM,
AS DEFINED BY NEC (OR CEC
WHERE ADOPTED) ART. 645,
SERVER ROOM, DATA CENTER, OR
COMPUTER ROOM, PROVIDE 1#2
INSULATED GREEN CONDUCTOR, "C
AND MECHANICALLY CONNECT TO
MAIN TELECOMMUNICATIONS
GROUNDING BUS AND, WHEN
LOCATED ON A TILE ACCESS
FLOOR, TO UNDER FLOOR SIGNAL
REFERENCE OR GROUNDING GRID
AS REQUIRED.
PROVIDE CONNECTION OF
GROUNDING CONDUCTORS/
BONDING JUMPERS PER
ART.250.8.
IF AVAILABLE ON THE PREMISES AT EACH BUILDING
AND/OR STRUCTURE SERVED, CONNECT EFFECTIVELY
GROUNDED STRUCTURAL STEEL OR EFFECTIVELY
GROUNDED UNDERGROUND METAL WATER PIPE WITHIN
5 FT FROM POINT OF ENTRANCE TO THE BUILDING
AND/OR STRUCTURE WITH TO THE SEPARATELY SYSTEM
PER ART. 250.30(A)(4)(1) & (A)(4)(2) - SEE RESPECTIVE
SYSTEM/DEVICE SCHEDULE FOR G.E.C. SIZE. WHERE
ACCESS TO EFFECTIVELY GROUNDED STRUCTURAL
STEEL OR EFFECTIVELY GROUNDED UNDERGROUND
METAL WATER PIPE IS SUFFICIENTLY REMOTE, THE
CONTRACTOR MAY ELECT TO INSTALL A COMMON
GROUNDING ELECTRODE CONDUCTOR(S) TO TIE (1) OR
MORE SEPARATELY DERIVED SYSTEMS TO THE REMOTE
GROUNDING ELECTRODES. DESIGN AND INSTALLATION
OF SUCH A SYSTEM SHALL FULLY COMPLY WITH ART.
250.30(A)(3).
PROVIDE BONDING (*) WITH 1 # cu., 1
1/4"C. TO NEAREST METAL, WATER PIPE
(HOT, COLD, SPRINKLER, SEWER,
BUILDING MOUNTED - INTERIOR OR
EXTERIOR ETC), UNINTENTIONALLY
UNGROUNDED BUILDING STEEL, GAS
PIPE, HVAC DUCTS IN THE BUILDING PER
ART. 250.104 (A), (B), & (C)
(*)
LPA
GEC
SIZEW
NAME KVA
V P
INPUT MIN
%Z
OUTPUT
V WP
A.I.C.
VALUE
K
VAL.
DIMENSIONSNEMA
REDUCED
SOUND
LEVEL H DW
WGT.WINDING
MATERIAL
T-A 150 COPPER 480 3 3 120/208 3 4 3.8 15,888 N/A 3/4"C, #3/0 N/A 1 50 35 29 1200
1. TRANSFORMERS SHALL BE DRY TYPE, INTEGRAL, SELF-COOLED, ENCLOSED DISTRIBUTION, TWO-WINDING TYPE PER UL 506. TRANSFORMERS SHALL BE PROVIDED WITH WINDINGS AS SPECIFIED IN THE TRANSFORMER SCHEDULE. EACH TRANSFORMER MUST UNDERGO RESISTANCE, IMPEDANCE AND RATIO TESTING, THE RESULTS OF WHICH SHALL BE PROVIDED AS PART OF THE TRANSFORMER SUBMITTAL PACKAGE.
2. TRANSFORMERS SHALL BE EQUIPPED WITH TWO (2) 2 1/2% FCAN AND TWO (2) 2 1/2% FCBN TAPS. TAP LEADS SHALL BE TERMINATED ON AN INTERNAL BLOCK WITH LUGS FOR CONNECTION OF INCOMING CONDUCTORS. THE TERMINAL COMPARTMENT SHALL BE LOCATED BELOW THE LEVEL OF THE TRANSFORMER WINDINGS. PROVIDE ACCESS TO TERMINALS FROM THE FRONT FOR WALL AND FLOOR MOUNTED TRANSFORMERS, AND FROM THE FRONT AND BOTTOM FOR SUSPENDED TRANSFORMERS.
3. VENTILATION OPENINGS SHALL BE LOCATED TO PERMIT PLACING THE TRANSFORMER IN A CORNER WITHIN 6" OF THE TWO ADJACENT WALLS. ENCLOSURE SHALL BE CONSTRUCTED OF HEAVY GAUGE STEEL, COATED INSIDE AND OUT WITH ZINC CHROMATE OR IRON OXIDE RUST INHIBITING PRIMER. ENCLOSURE SHALL THEN BE FINISHED IN GRAY ENAMEL. EACH TRANSFORMER SHALL BE FURNISHED WITH A MANUFACTURER'S NAMEPLATE LOCATED ON THE FRONT OF THE UNIT. THE NAMEPLATE SHALL BE ANODIZED ALUMINUM STENCILED WITH VOLTAGE, KVA RATING, K-RATING, PHASE, TAP ADJUSTMENTS AND WIRING DIAGRAMS.
4. VIBRATION DAMPERS (KORFUND COMPANY, MASON INDUSTRIES, VMC OR EQUAL) SHALL BE LOCATED AT EACH CORNER OF THE TRANSFORMER. THE DAMPERS SHALL BE A NEOPRENE ISOLATOR INCORPORATING A STEEL HOUSING CAPABLE OF RESISTING A SEISMIC LOAD OF 1.0 G IN ALL DIRECTIONS. THE DAMPER SHALL
CONSIST OF A CAPTIVE STEEL INSERT EMBEDDED INTO A NEOPRENE ELEMENT WHICH IS ENCLOSED BY A STEEL HOUSING WHICH ALSO INCLUDES FLOOR MOUNTING HOLES. THE ISOLATOR SHALL HAVE A RATED DEFLECTION OF .15 INCHES COMPRESSION, .12 INCHES IN TENSION AND .09 INCHES IN SHEAR.
TRANSFORMER SHALL BE BOLTED TO THE FLOOR (OR HOUSEKEEPING PAD WHEN REQUIRED) AT ALL FOUR CORNERS OR BOLTED TO THE WALL MOUNTING BRACKETS WHEN WALL-MOUNTED. WHEN SHOWN AS WALL-MOUNTED, PROVIDE EITHER MANUFACTURER'S STANDARD TRANSFORMER WALL MOUNTING BRACKET'S OR FIELD-FABRICATED MOUNTING SYSTEMS. WALL-MOUNTED TRANSFORMER INSTALLATIONS SHALL MEET THE SEISMIC BRACING REQUIREMENTS IN THE GENERAL ELECTRICAL SPECIFICATIONS.
5. STANDARD TRANSFORMERS SHALL HAVE CLASS 220 INSULATION, HAVING A 150 DEGREE CELSIUS TEMPERATURE RISE ABOVE 30 DEGREE CELSIUS AVERAGE AND 40 DEGREE CELSIUS MAXIMUM, WHEN OPERATING AT FULL LOAD - WITHOUT A LOSS OF LIFE. STANDARD TRANSFORMERS SHALL COMPLY WITH NEMA ENERGY EFFICIENCY STANDARD "TP-1".
6. K RATED TRANSFORMERS SHALL HAVE CLASS 220 INSULATION, HAVING A 115 DEGREE CELSIUS TEMPERATURE RISE ABOVE 30 DEGREE CELSIUS AVERAGE AND 40 DEGREE CELSIUS MAXIMUM, WHEN OPERATING AT FULL LOAD - WITHOUT A LOSS OF LIFE. K RATED TRANSFORMERS SHALL COMPLY WITH NEMA ENERGY EFFICIENCY STANDARD "TP-1".
7. USE FLEXIBLE CONDUIT FOR PRIMARY AND SECONDARY CONNECTIONS WITH A SEPARATE EQUIPMENT GROUND CONDUCTOR.
8. THE "MIN. %Z" COLUMN INDICATES THE MINIMUM ALLOWED TRANSFORMER IMPEDANCE.
9. THE "A.I.C. VALUE" COLUMN INDICATES THE INTERRUPTING CURRENT AT THE SECONDARY TERMINALS BASED UPON AN INTERRUPTING CURRENT OF INFINITY AT THE PRIMARY TERMINALS.
10. THE "K VALUE" COLUMN INDICATES THE MINIMUM UL APPROVED K RATING. K RATED TRANSFORMERS SHALL BE PROVIDED WITH DOUBLE SIZE NEUTRAL TERMINALS, ADDITIONAL COIL CAPACITY, AN ELECTROSTATIC SHIELD, AND SHALL BE UL LISTED FOR NON-LINEAR LOADS.
11. THE "GEC SIZE" COLUMN INDICATES THE MINIMUM CONDUIT AND COPPER GROUNDING ELECTRODE CONDUCTOR SIZE. THE G.E.C. AND CONDUIT SIZE SHALL BE INCREASED PER NEC OR CEC WHERE ADOPTED, TABLE 250.66 BY THE CONTRACTOR BASED ON EQUIVALENT SIZE OF THE TRANSFORMER SECONDARY CONDUCTORS.
12. WHEN THE TRANSFORMER SCHEDULE INDICATES A "REDUCED SOUND LEVEL" TRANSFORMER, PROVIDE A TRANSFORMER THAT PRODUCES 3 DECIBELS LESS SOUND AS COMPARED TO NEMA STANDARD SOUND LEVELS. WHEN REDUCED SOUND LEVEL TRANSFORMER IS NOT INDICATED, PROVIDE A TRANSFORMER THAT MEETS NEMA STANDARD SOUND LEVELS, WHICH ARE:
13. THE "DIMENSIONS" COLUMN INDICATES "H" HEIGHT, "W" WIDTH, AND "D" DEPTH. ALL DIMENSIONS AND WEIGHTS ARE BASED UPON SQUARE D PRODUCTS.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL COST IMPACTS OF LARGER DIMENSIONS FROM AN ALTERNATE MANUFACTURER.
14. TRANSFORMERS SHALL BE GROUNDED TO A CODE APPROVED GROUND SOURCE PER NEC, OR CEC WHERE ADOPTED, ARTICLE 250.30.
15. IF THE SINGLE LINE DIAGRAM INDICATES TWO (2) SECONDARY FEEDERS THE TRANSFORMER SHALL BE PROVIDED WITH A DOUBLE LUG KIT.
16. SHOP DRAWINGS SHALL BE SUBMITTED PER THE ELECTRICAL SUBMITTAL REQUIREMENTS SHOWING CONFORMANCE TO THESE SPECIFICATIONS.
17. TRANSFORMERS SHALL BE MANUFACTURED BY GE, CUTLER-HAMMER, SIEMENS, SQUARE D, OR OLSEN. 10-50 KVA - 45 DECIBELS
51-150 KVA - 50 DECIBELS
151-300 KVA - 55 DECIBELS
301-300 KVA - 60 DECIBELS
LPA
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
ELECTRICAL
DETAILS
E7.02
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN.T.S.
FLUSH EXTERIOR OUTLET BOX "WP -R" DETAIL 03
N.T.S.
ELEVATOR ROOM 09
NTS
UNDER SLAB CONDUIT RISER 04
N.T.S.
SEPARATELY DERIVED SYSTEM GROUND 01
N.T.S.
TRANSFORMER SYSTEM SPECIFICATIONS 11
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
LIGHTING FIXTURE TYPE AS
INDICATED ON PLANS
TO LIGHTING FIXTURE OUTLET
J-BOX ON SLAB ABOVE
ATTACHMENT TO
STRUCTURE (TYPICAL ONE
EACH CORNER). REFER TO
ARCHITECTURAL DETAIL
ATTACH FRAME-IN KIT TO
CEILING SYSTEM CHANNELS
PER MANUFACTURER
INSTRUCTIONS
14/A9.21
6" MAX
#10 TEK SCREWS LOCATED AT
OPPOSITE CORNERS OF RUNNERS - ONE SHOWN
FOR CLARITY. USE OF INTEGRAL FIXTURE
SUPPORT TABS OR UL-LISTED ACCESSORY
FIXTURE SUPPORT TABS PROVIDED BY FIXTURE
MANUFACTURER MAY BE USED IF ACCEPTABLE
WITH THE LOCAL AHJ.
LIGHT FIXTURE. DETAIL IS TYPICAL FOR
MOST RECESSED TROFFER AND LINEAR
FIXTURES.
INTEGRAL SUPPORT TAB OR
HARDWARE PER MANUFACTURER
SUPPORT CABLE ATTACHMENT TO
STRUCTURE PER ARCH. DETAIL
GENERAL NOTES:
1. INSTALLATION SHALL COMPLY WITH LATEST PUBLISHED EDITION OF THE INTERPRETATION OR REGULATION MANUAL" IR 25-2.13 AS ISSUED BY THE DIVISION OF THE STATE ARCHITECT.
2. ATTACHMENT TO CEILING / STRUCTURE SHALL NOT AFFECT ASSEMBLY RATING.
3. INSTALL SAFTEY WIRES PER THE FOLLOWING:
A. FIXTURES @ LESS THAN 56 LBS: INSTALL (2) #12 GA. SAFETY WIRES (SLACK.)
ONE ON EACH END OF FIXTURE DIAGONALLY OPPOSED AND CONNECTED TO STRUCTURE ABOVE.
B. FIXTURES @ 56 LBS OR GREATER: INSTALL (4) #12 GA SUPPORT WIRES (TAUT).
ONE ON EACH CORNER OF FIXTURE CONNECTED TO STRUCTURE. WIRES SHALL SUPPORT (4) TIMES THE WEIGHT OF THE FIXTURE.
C. FIXTURES @ LESS THAN 56 LBS AND 4'X4' MIN IN SIZE: INSTALL (4) #12 GA.
SAFETY WIRES (SLACK) AT EACH CORNER OF THE FIXTURE.
FOR GRID AND GRID SUPPORT/ATTACHMENT
TO STRUCTURE, REFER TO ARCHITECTURAL
DETAILS ON XX/A9.XX
XX/A9.XX
POLE
FINISH GRADE
PER LANDSCAPE
DRAWINGS
CONCRETE TOPPING PAD
AND FINISH PER
LANDSCAPE DRAWINGS
1 1
4 3
5 2
REFER TO LANDSCAPE
DRAWINGS.
BOND EQUIPMENT
GROUND TO POLE.
BRANCH CIRCUIT CONDUIT
PER SITE PLAN.
PROVIDE MINIMUM COVER OF
24" FROM FINISH GRADE.
POLE ANCHOR BOLTS PER
MANUFACTURER SPEC'S.
NOTES
1 2
3 4
5 SEE LANDSCAPE DETAIL 21/L5.01
DRAINAGE
ACCESS DOOR
LIGHT FIXTURE
WALL PER ARCHITECTURAL
PLANS
27" MAX / 80" MIN. A.F.FIF FIXTURE IS NOT LOCATED 27"
MAX. OR 80" MIN. A.F.F./A.F.G.
FIXTURE MAY NOT EXCEED 4"
MAX. PROJECTION.
PROJECTION
MOUNTING PER STRUTURAL
DETAIL (10/S6.92)
CEILING MATERIAL (FOR
SUSPENDED LAY-IN PANEL
CEILING, SEE ADDITIONAL
BRACING INFORMATION ON
DETAIL )
FIXTURE FLANGE
WHERE OCCURS
CONTRACTOR TO
FOLLOW MANUFACTURER
INSTALLATION
INSTRUCTIONS
ATTACHMENT TO
STRUCTURE (TYPICAL ONE
EACH CORNER). REFER TO
ARCHITECTURAL DETAIL
XX/A9.XX
XX/A9.XX
CABINET PER
ARCHITECTURE AND
INTERIORS REFER TO
VARIES0' - 1 1/2"1"H x 1/2"W x "L
CABLE RACEWAY
(FINISH PER
INTERIORS)
MOUNTING CLIP AND
FASTENERS PER
MANUFACTURER
LOW VOLTAGE
WIRING TO REMOTE
DRIVER LOCATED IN
VENTILATED
ACCESSIBLE
LOCATION PER
PLANS; ALL WIRING
TO BE CONCEALED
AND NOT VISABLE
UNDER CABINET
FIXTURE; REFER TO
FIXTURE SCHEDULE
X/AX.XX
SECTION VIEW A
3/4" DIAMETER CABLE
GROMMET WHERE
WIRING PASSES
THROUGH MILLWORK
PLAN VIEW B
LIGHT FIXTURE
(2) M8-32 BOLTS MINIMUM;
SEAL PENETRATION WITH
SILICONE TO PROTECT
FIXTURE FROM WATER
J-BOX (PROVIDED BY
CONTRACTOR)
CANOPY STRUCTURE ABOVE;
STRUCTURE TO BE SOLID,
NON-PERFORATED TO SHIELD
FIXTURE FROM WATER
PENETRATION.
SURFACE WIRING BOX
COVER PER MFG
EXPOSED CONDUIT; RUN
CONDUIT TIGHT TO
ELEMENTS AND IN A CLEAN
MANNER. CONFIRM FINAL
CONDUIT RUN LOCATION
WITH ARCHITECT PRIOR TO
INSTALLATION.
NOTE:
CONT R ACTOR TO FIELD
DRILL AND COLD SPRAY
GALVANIZE DRILL HOLES IN
STRUCTURE.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
LIGHTING DETAILS
E7.03
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN.T.S.
RECESSED DOWNLIGHT 9
1" = 1'-0"
RECESSED FIXTURE -GRID CEILING 2
N.T.S.
POLE WITH CONCRETE PAD 5
N.T.S.
WALL MOUNTED LIGHT FIXTURE 3N.T.S.
RECESSED FIXTURE -HARD CEILING 7
N.T.S.
UNDER CABINET MOUNTING DETAIL 10
3" = 1'-0"
SURFACE MOUNTED LIGHT FIXTURE (SIDE FEED)11
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
CANOPY, SLIP RING,
AND CABLE COUPLER
PER MANUFACTURER
1/16" DIAMETER MIN.
MOUNTING/SUPPORT
CABLE AND POWER
CORD PER
MANUFACTURER
BUSHING AND NPT
FITTING TO J-BOX
LUMINAIRE
CEILING SYSTEM PER
ARCHITECTURAL DRAWINGS
6" MAX.ATTACH TO STRUCTURE
(4) #12 SPLAY WIRES PER FIXTURE,
45° IN EACH DIRECTION, 90° APART.
12'-0" MAXIMUM SPACING.
(2) CABLE COUPLERS (GRIPLOCK
SYSTEMS #CC-UNICROSS)
CONNECTING SEISMIC SWAY CABLES
AND FIXTURE SUPPORT CABLE (TYP)
(SEE ARCHITECTURAL DETAIL)
(SEE DETAIL 24/E7.04)
NOTES:
1. SUSPENSION SYSTEMS FOR LIGHT FIXTURES WHICH, AS INSTALLED, ARE FREE TO SWING A MINIMUM OF 45° FROM THE VERTICAL IN ALL
DIRECTIONS BELOW THE CEILING WITHOUT CONTACTING
OBSTRUCTIONS SHALL BE ASSUMED TO COMPLY WITH THE LATERAL-
FORCE REQUIREMENTS OF
2. IF FIXTURES CANNOT SWING A MINIMUM OF 45° FROM THE VERTICAL IN
ALL DIRECTIONS WITHOUT CONTACTING OBSTRUCTIONS, PROVIDE ALL
COMPONENTS NECESSARY FOR CABLE SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES.
3. ALL COMPONENTS SHALL BE APPROVED FOR A COMPLETE CODE-
COMPLIANT SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES. CABLE BRACING SYSTEM SHALL NOT BE DRAWN
TAUT TO AVOID DAMAGING THE BRACING SYSTEM DURING WALL
MOVEMENT CAUSED BY EARTHQUAKES. ADJUST TENSION PER
BRACING SYSTEM MFGR RECOMMENDATIONS.
4. SUPPORT TYPICAL FOR FEED & NON FEED POINT (WITHOUT J-BOX AND FLEX).
5. SHOULD A CONFLICT OCCUR BETWEEN FIXTURE SUPPORT DETAIL AND
HVAC DUCT ROUTING, EC SHALL INCLUDE ALL COSTS IN BASE BID TO PROVIDE A UNISTRUT "TRAPEZE"
WITH 3/8" DIA THREADED ROD HANGERS AROUND THE HVAC DUCT OR OTHER OBSTRUCTION. TRAPEZE SHALL BE SUBMITTED TO PROJECT
STRUCTURAL ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION OR OF ORDERING TRAPEZE MATERIAL.
(SEE ARCHITECTURAL DETAIL)
2019 CBC SECTION 1617A.1.18-21, ASCE 7-13
CANOPY, SLIP RING, AND CABLE
COUPLER PER MANUFACTURER
1/16" DIAMETER MIN.
MOUNTING/SUPPORT
CABLE AND POWER
CORD PER
MANUFACTURER
BUSHING AND NPT
FITTING TO J-BOX
LUMINAIRE
CABLE COUPLER (GRIPLOCK
SYSTEMS #CC-UNICROSS)
CONNECTING SEISMIC SWAY CABLES
AND FIXTURE SUPPORT CABLE
(4) #12 SPLAY WIRES PER FIXTURE
((2) ON EACH END OF FIXTURE),
SPLAYED @ 45° FROM
LONGITUDINAL AXIS OF FIXTURE
6" MAX.A. SECTION
B. PLAN
LUMINAIRE
(4) #12 SPLAY WIRES PER FIXTURE ((2) ON EACH
END OF FIXTURE), SPLAYED @ 45° FROM
LONGITUDINAL AXIS OF FIXTURE
45.00°B
A
CEILING SYSTEM PER
ARCHITECTURAL DRAWINGS
ATTACH TO STRUCTURE
(SEE ARCHITECTURAL DETAIL)
(SEE DETAIL 24/E7.04)
NOTES:
1. SUSPENSION SYSTEMS FOR LIGHT FIXTURES WHICH, AS INSTALLED, ARE FREE TO SWING A MINIMUM OF 45° FROM THE VERTICAL IN ALL
DIRECTIONS BELOW THE CEILING WITHOUT CONTACTING
OBSTRUCTIONS SHALL BE ASSUMED TO COMPLY WITH THE LATERAL-
FORCE REQUIREMENTS OF
2. IF FIXTURES CANNOT SWING A MINIMUM OF 45° FROM THE VERTICAL IN
ALL DIRECTIONS WITHOUT CONTACTING OBSTRUCTIONS, PROVIDE ALL
COMPONENTS NECESSARY FOR CABLE SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES.
3. ALL COMPONENTS SHALL BE APPROVED FOR A COMPLETE CODE-
COMPLIANT SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES. CABLE BRACING SYSTEM SHALL NOT BE DRAWN
TAUT TO AVOID DAMAGING THE BRACING SYSTEM DURING WALL
MOVEMENT CAUSED BY EARTHQUAKES. ADJUST TENSION PER
BRACING SYSTEM MFGR RECOMMENDATIONS.
4. SUPPORT TYPICAL FOR FEED & NON FEED POINT (WITHOUT J-BOX AND FLEX).
5. SHOULD A CONFLICT OCCUR BETWEEN FIXTURE SUPPORT DETAIL AND
HVAC DUCT ROUTING, EC SHALL INCLUDE ALL COSTS IN BASE BID TO PROVIDE A UNISTRUT "TRAPEZE"
WITH 3/8" DIA THREADED ROD HANGERS AROUND THE HVAC DUCT OR OTHER OBSTRUCTION. TRAPEZE SHALL BE SUBMITTED TO PROJECT
STRUCTURAL ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION OR OF ORDERING TRAPEZE MATERIAL.
(SEE ARCHITECTURAL DETAIL)
2019 CBC SECTION 1617A.1.18-21, ASCE 7-13
CANOPY, SLIP RING, AND
CABLE COUPLER PER
MANUFACTURER
1/16" DIAMETER MIN.
MOUNTING/SUPPORT
CABLE AND POWER
CORD PER
MANUFACTURER
BUSHING AND NPT
FITTING TO J-BOX
LUMINAIRE
WALL AND BLOCKING PER
ARCHITECTURAL/STRUCTURAL
DRAWINGS
(2) CABLE COUPLERS (GRIPLOCK
SYSTEMS #CC-UNICROSS) CONNECTING
SEISMIC SWAY CABLES AND FIXTURE
SUPPORT CABLE @ 90° (TYP)
SEISMIC SWAY AIRCRAFT CABLES TO
MATCH AIRCRAFT CABLE PROVIDED BY
FIXTURE MANUFACTURER (GRIPLOCK
SYSTEMS OR EQUAL) PROVIDE CABLES
IN BOTH X & Y DIRECTION @ 90° @ EACH
CABLE COUPLER
2-PART ADJUSTABLE COUPLER
(GRIPLOCK SYSTEMS #25Z-
M13-1420-SL) FASTENED TO WALL.6" MAX.CEILING SYSTEM PER
ARCHITECTURAL DRAWINGS
NOTES:
1. SUSPENSION SYSTEMS FOR LIGHT FIXTURES WHICH, AS INSTALLED, ARE FREE TO SWING A MINIMUM OF 45° FROM THE VERTICAL IN ALL
DIRECTIONS BELOW THE CEILING WITHOUT CONTACTING
OBSTRUCTIONS SHALL BE ASSUMED TO COMPLY WITH THE LATERAL-
FORCE REQUIREMENTS OF
2. IF FIXTURES CANNOT SWING A MINIMUM OF 45° FROM THE VERTICAL IN
ALL DIRECTIONS WITHOUT CONTACTING OBSTRUCTIONS, PROVIDE ALL
COMPONENTS NECESSARY FOR CABLE SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES.
3. ALL COMPONENTS SHALL BE APPROVED FOR A COMPLETE CODE-
COMPLIANT SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES. CABLE BRACING SYSTEM SHALL NOT BE DRAWN
TAUT TO AVOID DAMAGING THE BRACING SYSTEM DURING WALL
MOVEMENT CAUSED BY EARTHQUAKES. ADJUST TENSION PER
BRACING SYSTEM MFGR RECOMMENDATIONS.
4. SUPPORT TYPICAL FOR FEED & NON FEED POINT (WITHOUT J-BOX AND FLEX).
5. SHOULD A CONFLICT OCCUR BETWEEN FIXTURE SUPPORT DETAIL AND
HVAC DUCT ROUTING, EC SHALL INCLUDE ALL COSTS IN BASE BID TO PROVIDE A UNISTRUT "TRAPEZE"
WITH 3/8" DIA THREADED ROD HANGERS AROUND THE HVAC DUCT OR OTHER OBSTRUCTION. TRAPEZE SHALL BE SUBMITTED TO PROJECT
STRUCTURAL ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION OR OF ORDERING TRAPEZE MATERIAL.
(SEE ARCHITECTURAL DETAIL)
(METAL STUD:#10 SHEET METAL
SCREW MIN.)
(WOOD BLOCKING:#10 WOOD
SCREW W/ 3" EMBED)
(CONRETE: 3/8" DIA HILTI KB-TZ2
ANCHOR W/ 2 1/2" EMBED PER
ICC-ES ESR-4561)
(SEE DETAIL 24/E7.04)
2019 CBC SECTION 1617A.1.18-21, ASCE 7-13
FOR FIXTURE SUPPORT AT
GRID/T-BAR CEILING, REFER
TO DETAIL XX/E7.XX
CANOPY, SLIP
RING, AND CABLE
COUPLER PER
MANUFACTURER
1/16" DIAMETER MIN.
MOUNTING/SUPPORT
CABLE AND POWER
CORD PER MFG
BUSHING AND
NPT FITTING TO
J-BOX
LUMINAIRE
WALL AND BLOCKING
PER ARCHITECTURAL/
STRUCTURAL
DRAWINGS
CABLE COUPLER
(GRIPLOCK SYSTEMS
#CC-UNICROSS)
CONNECTING SEISMIC
SWAY CABLE AND
FIXTURE SUPPORT
CABLE (TYP).
SEISMIC SWAY AIRCRAFT
CABLE IN DIRECTION OF
NARROWEST LENGTH
BETWEEN WALLS. CABLE
TO MATCH AIRCRAFT
CABLE PROVIDED BY
FIXTURE MFG (GRIPLOCK
SYSTEMS OR EQUAL)
2-PART ADJUSTABLE
COUPLER (GRIP LOCK
SYSTEMS ##25Z-
M13-1420-SL)
FASTENED TO WALL.
CEILING SYSTEM PER
ARCHITECTURAL
DRAWINGS
B A
A. SECTION B. PLAN
FIXTURE TO FREELY
SWING PERPENDICULAR
TO CABLING A MINIMUM
OF 45 DEGREES
WITHOUT CONTACTING
OBSTRUCTIONS PER
NOTE #1.
LUMINAIRE6" MAX.(METAL STUD:#10 SHEET
METAL SCREW MIN.)
(WOOD BLOCKING:#10
WOOD SCREW W/ 3"
EMBED)
(CONRETE: 3/8" DIA HILTI
KB-TZ2 ANCHOR W/ 2 1/2"
EMBED PER ICC-ES
ESR-4561)
(SEE DETAIL 24/E7.04)
NOTES:
1. SUSPENSION SYSTEMS FOR LIGHT FIXTURES WHICH, AS INSTALLED, ARE FREE TO SWING A MINIMUM OF 45° FROM THE VERTICAL IN ALL
DIRECTIONS BELOW THE CEILING WITHOUT CONTACTING
OBSTRUCTIONS SHALL BE ASSUMED TO COMPLY WITH THE LATERAL-
FORCE REQUIREMENTS OF
2. IF FIXTURES CANNOT SWING A MINIMUM OF 45° FROM THE VERTICAL IN
ALL DIRECTIONS WITHOUT CONTACTING OBSTRUCTIONS, PROVIDE ALL
COMPONENTS NECESSARY FOR CABLE SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES.
3. ALL COMPONENTS SHALL BE APPROVED FOR A COMPLETE CODE-
COMPLIANT SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES. CABLE BRACING SYSTEM SHALL NOT BE DRAWN
TAUT TO AVOID DAMAGING THE BRACING SYSTEM DURING WALL
MOVEMENT CAUSED BY EARTHQUAKES. ADJUST TENSION PER
BRACING SYSTEM MFGR RECOMMENDATIONS.
4. SUPPORT TYPICAL FOR FEED & NON FEED POINT (WITHOUT J-BOX AND FLEX).
5. SHOULD A CONFLICT OCCUR BETWEEN FIXTURE SUPPORT DETAIL AND
HVAC DUCT ROUTING, EC SHALL INCLUDE ALL COSTS IN BASE BID TO PROVIDE A UNISTRUT "TRAPEZE"
WITH 3/8" DIA THREADED ROD HANGERS AROUND THE HVAC DUCT OR OTHER OBSTRUCTION. TRAPEZE SHALL BE SUBMITTED TO PROJECT
STRUCTURAL ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION OR OF ORDERING TRAPEZE MATERIAL.
(SEE ARCHITECTURAL DETAIL)
2019 CBC SECTION 1617A.1.18-21, ASCE 7-13
CANOPY, SLIP RING, AND CABLE
COUPLER PER MANUFACTURER
1/16" DIAMETER MIN.
MOUNTING CABLE AND
POWER CORD PER
MANUFACTURER
BUSHING AND NPT
FITTING TO J-BOX
LUMINAIRE
(1) CABLE COUPLER (GRIPLOCK SYSTEMS
#CC-UNICROSS) CONNECTING SEISMIC
SWAY CABLE AND FIXTURE SUPPORT
CABLE (TYP)
(2) #12 SPLAY WIRES PER FIXTURE (ONE ON
EACH END OF THE FIXTURE), TO LIMIT
FIXTURE FROM SWINGING IN
LONGITUDINAL DIRECTION.
FIXTURE TO FREELY SWING IN LATERAL
DIRECTION A MINIMUM OF 45° WITHOUT
CONTACTING OBSTRUCTIONS PER NOTE #1 6" MAX.CEILING SYSTEM PER
ARCHITECTURAL DRAWINGS
ATTACH TO STRUCTURE
(SEE ARCHITECTURAL DETAIL)
(SEE DETAIL 24/E7.04)
NOTES:
1. SUSPENSION SYSTEMS FOR LIGHT FIXTURES WHICH, AS INSTALLED, ARE FREE TO SWING A MINIMUM OF 45° FROM THE VERTICAL IN ALL
DIRECTIONS BELOW THE CEILING WITHOUT CONTACTING
OBSTRUCTIONS SHALL BE ASSUMED TO COMPLY WITH THE LATERAL-
FORCE REQUIREMENTS OF
2. IF FIXTURES CANNOT SWING A MINIMUM OF 45° FROM THE VERTICAL IN
ALL DIRECTIONS WITHOUT CONTACTING OBSTRUCTIONS, PROVIDE ALL
COMPONENTS NECESSARY FOR CABLE SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES.
3. ALL COMPONENTS SHALL BE APPROVED FOR A COMPLETE CODE-
COMPLIANT SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES. CABLE BRACING SYSTEM SHALL NOT BE DRAWN
TAUT TO AVOID DAMAGING THE BRACING SYSTEM DURING WALL
MOVEMENT CAUSED BY EARTHQUAKES. ADJUST TENSION PER
BRACING SYSTEM MFGR RECOMMENDATIONS.
4. SUPPORT TYPICAL FOR FEED & NON FEED POINT (WITHOUT J-BOX AND FLEX).
5. SHOULD A CONFLICT OCCUR BETWEEN FIXTURE SUPPORT DETAIL AND
HVAC DUCT ROUTING, EC SHALL INCLUDE ALL COSTS IN BASE BID TO PROVIDE A UNISTRUT "TRAPEZE"
WITH 3/8" DIA THREADED ROD HANGERS AROUND THE HVAC DUCT OR OTHER OBSTRUCTION. TRAPEZE SHALL BE SUBMITTED TO PROJECT
STRUCTURAL ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION OR OF ORDERING TRAPEZE MATERIAL.
(SEE ARCHITECTURAL DETAIL)
2019 CBC SECTION 1617A.1.18-21, ASCE 7-13
CANOPY, SLIP RING, AND CABLE COUPLER PER
MANUFACTURER 1/16" DIAMETER MIN.
MOUNTING/SUPPORT
CABLE AND POWER CORD
PER MANUFACTURER
BUSHING AND NPT
FITTING TO J-BOX
LUMINAIRE6" MAX.CEILING SYSTEM PER ARCHITECTURAL DRAWINGS (2) #12 SPLAY WIRES PER FIXTURE, 180° APART, 45° IN
DIRECTION OF NARROWEST LENGTH BETWEEN WALLS.
12'-0" MAXIMUM SPACING.
FIXTURE TO FREELY SWING IN OPPOSITE DIRECTION A
MINIMUM OF 45 DEGREES WITHOUT CONTACTING
OBSTRUCTIONS PER NOTE #1.
(1) CABLE COUPLER (GRIPLOCK SYSTEMS #CC-
UNICROSS) CONNECTING SEISMIC SWAY CABLE AND
FIXTURE SUPPORT CABLE (TYP)
ATTACH TO STRUCTURE
(SEE ARCHITECTURAL DETAIL XX/A9.XX)
(SEE DETAIL 24/E7.04)
NOTES:
1. SUSPENSION SYSTEMS FOR LIGHT FIXTURES WHICH, AS INSTALLED, ARE FREE TO SWING A MINIMUM OF 45° FROM THE VERTICAL IN ALL
DIRECTIONS BELOW THE CEILING WITHOUT CONTACTING
OBSTRUCTIONS SHALL BE ASSUMED TO COMPLY WITH THE LATERAL-
FORCE REQUIREMENTS OF
2. IF FIXTURES CANNOT SWING A MINIMUM OF 45° FROM THE VERTICAL IN
ALL DIRECTIONS WITHOUT CONTACTING OBSTRUCTIONS, PROVIDE ALL
COMPONENTS NECESSARY FOR CABLE SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES.
3. ALL COMPONENTS SHALL BE APPROVED FOR A COMPLETE CODE-
COMPLIANT SEISMIC BRACING SYSTEM TO LIMIT MOVEMENT OF CABLE HUNG FIXTURES. CABLE BRACING SYSTEM SHALL NOT BE DRAWN
TAUT TO AVOID DAMAGING THE BRACING SYSTEM DURING WALL
MOVEMENT CAUSED BY EARTHQUAKES. ADJUST TENSION PER
BRACING SYSTEM MFGR RECOMMENDATIONS.
4. SUPPORT TYPICAL FOR FEED & NON FEED POINT (WITHOUT J-BOX AND FLEX).
5. SHOULD A CONFLICT OCCUR BETWEEN FIXTURE SUPPORT DETAIL AND
HVAC DUCT ROUTING, EC SHALL INCLUDE ALL COSTS IN BASE BID TO PROVIDE A UNISTRUT "TRAPEZE"
WITH 3/8" DIA THREADED ROD HANGERS AROUND THE HVAC DUCT OR OTHER OBSTRUCTION. TRAPEZE SHALL BE SUBMITTED TO PROJECT
STRUCTURAL ENGINEER FOR REVIEW PRIOR TO CONSTRUCTION OR OF ORDERING TRAPEZE MATERIAL.
(SEE ARCHITECTURAL DETAIL)
2019 CBC SECTION 1617A.1.18-21, ASCE 7-13
CABLE COUPLER (GRIPLOCK
SYSTEMS #CC-UNICROSS)
CONNECTING SEISMIC SWAY
CABLES AND FIXTURE
SUPPORT CABLE
#12 SPLAY WIRES ((2) ON EACH
END OF FIXTURE), SPLAYED @
45° FROM LONGITUDINAL AXIS
OF FIXTURE
1/16" DIAMETER MIN.
MOUNTING/SUPPORT CABLE
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Job Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
408-780-7200 Office
408-780-7201 Fax
60 South Market Street,
Suite 150
San Jose, California 95113
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SPACE SHUTTLE EXHIBIT ANDEDUCATION BUILDINGCOLUMBIA WAYDOWNEY, CA 902423055401
LIGHTING DETAILS
E7.04
08/01/2025
N.T.S.
PENDANT FIXTURE -SPLAY BRACING1 2
N.T.S.
PENDANT FIXTURE -SPLAY BRACING (LINEAR)3
N.T.S.
PENDANT FIXTURE -HORIZONTAL BRACING 1N.T.S.
PENDANT FIXTURE -HORIZONTAL BRACING (SINGLE DIRECTION)13 N.T.S.
PENDANT FIXTURE -SPLAY BRACING (LINEAR, SINGLE DIRECTION)15 N.T.S.
PENDANT FIXTURE -SPLAY BRACING (SINGLE DIRECTION)14
N.T.S.
CC -UNICROSS CABLE COUPLER 24
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401 ENERGY
COMPLIANCE
FORMS
E8.01
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401 ENERGY
COMPLIANCE
FORMS
E8.02
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGNOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
LIGHTING SITE
PHOTOMETRIC
E9.01
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
Label LLF Avg Max Min Max/Min
MEZZANINE 0.9 8.1 fc 28.3 fc 0.8 fc 35.3:1
NOTE:
THIS LIGHTING CALCULATION REPRESENTS ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA TAKEN UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY (IES) APPROVED METHODS.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
LIGHTING SITE
EMERGENCY
PHOTOMETRIC
E9.02
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
Label LLF Avg Max Min Max/Min
MEZZANINE 0.9 8.1 fc 28.3 fc 0.8 fc 35.3:1
NOTE:
THIS LIGHTING CALCULATION REPRESENTS ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA TAKEN UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY (IES) APPROVED METHODS.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
REF.TVTVCGLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDEM EM
EM
EM
EM
EM
EM
EM
EM
EM
EMEMEMEM
EM
EM EM
EMEM
EM EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
23.0 26.1 27.9 28.4 28.1 26.6 23.8
29.3 32.9 35.6 36.0 35.4 33.3 30.6
35.3 38.6 42.1 42.4 42.1 38.8 35.9
38.1 41.7 44.7 45.2 45.1 41.6 37.8
38.0 42.3 44.9 45.5 44.8 42.2 37.9
38.1 42.0 45.1 45.1 44.5 41.5 38.1
36.0 38.9 41.9 42.0 41.9 38.5 35.4
30.5 33.3 35.1 35.6 35.4 32.9 29.4
23.8 26.7 27.9 28.2 27.9 26.4 23.0
16.3 18.0 17.0
21.0 22.5 22.0
23.9 24.7 24.3
22.0 22.9 21.7
17.4 18.8 17.4
14.9 18.1 21.3 22.5
17.6 21.6 25.5 27.5
19.8 24.1 28.4 30.6
21.1 25.5 29.4 31.2
17.2 18.7 17.0
16.2 17.8 16.2
30.5 34.5 37.1 37.5 36.8 34.7 31.4
37.3 40.8 44.4 44.6 44.2 40.9 37.6
40.8 44.8 47.6 48.2 48.0 45.1 40.2
40.8 45.3 48.1 48.8 48.0 45.1 40.4
40.7 44.8 48.4 48.5 47.8 44.7 40.6
38.6 41.9 45.2 45.4 45.1 41.4 37.7
32.8 36.2 38.1 38.6 38.3 35.5 31.2
11.3 10.9 10.8 10.2
12.8 14.2 14.2 12.5
13.6 17.3 17.0 14.1
14.0 18.2 17.9 15.0
14.5 18.8 18.5 16.0
15.3 18.7 19.9 16.7
17.7 19.6 18.0 20.3 20.8 19.6 16.3
19.2 22.7 23.6 22.6 21.4 20.3 16.3
18.3 19.5 21.1 22.5 21.1 19.8 16.1
14.5 20.8 21.0 17.4 15.6
13.9 18.5 20.6 17.2 14.8
13.4 18.0 18.8 15.6 13.2
12.9 17.3 17.0 14.9 13.9
12.4 15.5 15.9 15.5 13.1
11.5 13.8 14.6 13.8 11.5
10.7 12.4 11.1 12.8 12.5 11.7 9.4
32.3 35.9 34.8 36.8 34.1 30.6 32.0 30.2 27.2 28.5 24.9 23.6 25.1 19.0
17.3 39.1 41.5 39.2 40.5 36.6 33.3 33.8 30.5 26.9 27.8 24.2 24.1 25.5 19.6
29.3 40.1 39.4 36.5 35.4 32.2 29.8 24.0 22.2 19.8 15.6 12.3 13.6 16.8 14.4
25.3 33.8 32.6 19.3 18.8 17.8 12.5 11.4 13.4 17.0 14.5
22.2 21.4 22.7 20.0 17.8 16.5 22.8 18.4
19.9 18.3 21.3 19.3 17.2 15.2 21.2 17.1
19.5 24.1 26.7 26.5 25.5 25.8 27.7 28.7 27.5 25.8 25.5 26.5 26.2 22.8 17.8
24.1 30.5 34.2 33.2 30.7 31.2 34.5 36.5 34.3 31.2 31.0 33.3 33.6 28.9 22.4
27.4 34.9 39.5 37.9 34.8 35.3 39.4 42.0 39.2 35.3 35.0 37.9 38.6 33.1 25.5
28.6 36.0 40.7 39.3 36.6 37.2 41.0 43.3 40.7 37.0 36.7 39.2 39.5 34.2 26.8
29.1 36.1 41.0 40.0 37.6 38.2 41.5 43.4 41.2 38.0 37.6 39.6 39.5 34.6 27.4
30.2 39.6 43.8 42.0 39.1 39.6 43.5 45.8 43.2 39.4 39.0 41.6 41.9 36.3 28.4
30.7 41.6 45.6 43.4 40.2 40.7 44.9 47.5 44.4 40.2 39.8 42.7 43.3 37.4 29.1
29.3 34.8 34.2 30.6 27.5 25.0 37.6 42.7 45.2 43.1 39.8 40.2 43.9 46.1 43.4 39.5 39.0 41.4 41.7 36.4 28.7
32.4 40.5 40.5 37.5 38.0 37.4 39.5 42.6 44.3 42.1 39.1 39.3 42.3 44.2 41.9 38.4 37.7 39.7 39.9 35.2 28.1
26.0 30.6 29.4 41.9 43.0 42.3 41.6 43.9 45.4 42.4 38.6 38.6 42.2 44.4 41.6 37.5 36.9 39.4 40.3 35.4 27.8
31.8 42.8 42.1 41.0 43.0 44.4 41.1 36.9 36.7 40.4 42.9 39.9 35.7 35.1 38.0 39.4 34.5 26.3
27.8 32.5 35.1 35.9 37.5 38.5 35.8 32.4 32.4 35.2 36.9 34.6 31.5 31.0 33.0 34.0 30.5
19.8 18.3 15.5 12.7
24.0 22.2 18.5 14.5
26.6 24.3 19.5 14.1
27.0 23.6 15.1 11.2
9.4 10.3 10.8 10.6 9.7 7.8
12.3 13.5 14.1 14.0 13.3 11.2
17.0 19.0 20.0 19.6 18.6 17.9 21.0 23.0 24.9 26.3 26.0 23.5 19.7 16.9
23.2 26.4 28.6 27.7 25.3 23.5 24.4 27.9 31.9 34.1 34.0 31.7 28.3 26.6 27.6 30.8 32.8 32.7 29.6 24.3 19.0
21.9 25.5 29.7 34.1 35.6 34.3 30.6 28.0 28.4 32.5 37.5 40.5 40.5 37.4 32.7 30.3 32.4 36.0 39.2 39.2 35.2 28.4 21.9
24.6 23.8 27.2 32.5 37.2 39.4 37.7 34.0 30.4 30.8 35.2 40.6 43.8 43.6 39.8 35.1 32.5 34.4 39.1 42.1 41.9 38.2 31.0 23.8
26.1 24.7 27.7 32.8 37.9 39.9 38.6 34.9 31.8 31.8 36.2 41.0 44.1 43.7 40.5 35.9 33.6 35.4 39.2 42.3 42.1 38.1 31.3 24.2
25.3 24.4 27.5 33.3 37.8 40.0 38.5 35.3 32.4 32.6 36.5 41.0 43.8 43.6 40.3 36.4 33.9 35.4 39.4 42.1 41.2 37.3 31.4 24.4
17.9 23.3 27.9 34.6 39.7 42.0 41.0 36.7 33.6 33.3 37.5 42.9 45.7 45.6 42.0 37.2 34.8 36.6 41.0 44.0 43.3 38.8 32.3 24.9
14.8 20.3 27.5 35.4 41.3 43.8 42.5 38.2 34.0 34.2 38.5 44.5 47.2 47.2 43.7 37.6 35.1 37.0 42.2 45.3 44.8 40.0 32.9 25.2
14.9 19.0 26.3 34.3 41.1 43.6 42.3 38.2 33.7 34.0 38.5 44.4 47.3 46.7 42.6 37.5 34.9 37.0 41.8 45.0 44.3 40.1 32.3 25.0
14.8 18.8 24.9 32.7 38.6 41.1 40.4 36.5 33.3 33.3 37.4 42.2 44.6 44.2 41.2 36.3 33.9 36.1 40.0 42.7 41.8 37.6 31.1 24.2
14.8 18.7 24.5 31.7 37.3 39.7 38.9 35.8 32.6 32.8 36.3 40.7 43.0 42.8 39.5 35.9 33.9 35.2 38.4 41.4 40.3 36.6 30.2 23.3
14.5 18.3 24.8 31.9 37.6 40.4 39.5 35.8 32.9 32.5 36.3 40.9 43.8 43.2 40.2 35.3 33.2 34.7 39.0 41.3 41.2 37.0 30.1 22.9
14.0 17.8 24.1 31.7 37.4 40.1 39.0 35.1 31.5 31.6 35.5 40.5 43.4 43.0 39.1 34.4 32.1 33.8 38.1 41.0 41.2 36.9 29.8 22.1
13.1 17.0 22.7 29.4 35.1 37.4 36.0 32.9 29.5 29.6 33.0 37.3 40.1 39.6 36.5 32.0 29.8 31.1 34.9 38.1 38.1 34.1 27.4 20.4
11.3 15.6 19.8 25.1 29.5 31.3 30.6 27.8 25.8 25.2 27.8 31.5 33.5 33.0 30.6 27.2 25.7 27.0 29.6 31.7 31.4 28.5 23.2 17.7
17.0 21.1 24.4 25.9 25.3 23.4 20.9
6.5 11.5 15.8 19.9 23.2 24.4 23.6 20.5 15.8
8.4 11.8 16.5 21.8 25.7 27.0 25.5 21.4 16.5
8.6 12.1 17.5 23.9 28.8 30.3 28.1 23.2 17.5
8.2 11.6 17.1 23.7 28.8 30.3 28.0 22.8 16.9
7.6 10.5 15.2 20.8 25.0 26.3 24.6 20.1 15.1
6.6 8.9 12.2 15.9 18.8 19.7 18.4 15.5 12.1
5.8 7.5 9.6 11.9 13.5 14.0 13.3 11.6 9.3
18.0 17.4 19.9 18.6 17.3 14.7 21.1 17.7
15.4 19.5 14.7 20.2 18.5 20.5 19.4 18.0 16.0 22.7 19.0
21.5 29.3 25.7 21.0 17.7 14.8 12.7 11.8 14.1 12.1 11.4 13.0 16.9 14.7
16.5 32.5 34.2 32.1 31.5 28.2 16.0 15.8 15.2 14.6 12.2 13.1 16.5 14.3
33.3 36.0 34.7 37.1 33.1 27.6 25.8 24.7 22.9 25.6 24.7 24.4 25.6 19.7
29.9 33.1 32.3 36.1 31.7 28.1 27.7 25.6 23.6 26.7 25.5 24.4 25.8 19.3
10.5 11.8 13.7 15.4 16.6 17.5 18.1 18.7 19.4 20.3 21.4 7.9 10.5 13.4 14.4 12.7 10.9 11.4 13.6 11.9 10.6 10.6 12.5 13.2 10.6 8.1 8.1 8.4 10.4 13.1 13.7 12.4 12.1 13.7 14.2 13.2 12.2 12.4 13.5 14.0 13.7 13.5 13.9 14.2 13.7 12.8 13.0 13.3 12.9 12.4 12.5 13.1 13.2 12.8 12.2 11.9 12.0 12.1 11.0 10.7 10.8 11.0 10.8 10.2 10.2 10.5 10.5 10.2 9.7 9.5 9.5 9.1 8.0
11.9 13.6 16.0 17.4 17.8 18.1 18.9 19.8 20.6 21.8 23.2 10.8 14.9 19.8 21.2 17.8 14.9 16.5 20.7 21.5 18.1 15.2 14.9 18.6 19.4 15.0 10.4 10.2 11.2 15.0 19.6 20.8 18.1 15.6 16.2 18.6 19.3 17.5 16.0 16.5 18.3 18.9 18.1 17.4 17.8 18.2 17.5 16.5 16.5 17.3 17.7 16.9 15.8 15.6 16.1 16.2 15.6 14.9 14.9 15.3 15.6 13.7 13.0 13.0 13.2 13.4 13.0 12.2 12.2 12.6 12.7 12.3 11.7 11.6 11.5 11.1 9.8
13.6 15.8 17.7 17.7 18.4 19.4 20.4 21.4 22.7 24.5 25.7 12.4 17.1 22.7 23.9 19.7 16.5 18.6 23.6 24.9 20.7 17.4 17.0 21.1 21.9 16.4 11.3 11.4 12.8 17.2 22.4 23.8 20.6 17.6 18.0 20.3 21.2 19.5 18.0 18.6 20.5 21.2 20.2 19.4 19.4 19.7 19.0 18.3 18.5 19.5 20.0 19.1 20.0 19.9 20.6 20.9 21.4 31.6 32.5 33.6 34.8 23.8 23.0 21.6 20.5 19.1 17.9 13.6 13.7 14.1 14.2 13.7 13.0 12.9 13.2 12.3 10.8
15.1 17.2 17.8 18.5 19.6 20.5 21.4 22.8 24.8 26.5 27.9 31.5 36.5 39.6 40.2 37.1 35.1 36.9 40.7 41.1 37.1 35.1 24.3 25.6 28.2 18.5 16.8 28.8 30.5 34.9 40.3 41.9 39.6 36.7 36.9 38.2 39.1 38.3 37.6 39.0 39.8 40.8 40.1 38.6 38.5 38.1 38.0 37.7 38.2 39.9 39.6 39.4 38.3 37.2 37.1 36.3 36.1 36.1 36.4 37.1 36.1 25.4 24.3 23.0 22.4 20.8 19.0 14.2 14.3 14.7 14.7 14.3 13.5 13.5 13.8 13.6 11.2
16.3 17.8 18.3 19.6 20.5 21.5 22.3 23.6 25.7 27.6 29.4 30.3 28.7 29.0 30.1 29.8 29.5 29.2 29.6 30.1 31.2 32.1 32.1 33.3 35.3 36.3 36.3 35.1 34.3 35.3 37.4 36.7 34.6 33.8 24.6 24.1 26.7 20.3 20.1 29.8 31.4 33.9 37.2 38.0 37.5 35.9 35.9 36.5 37.0 36.8 37.1 37.9 38.2 38.7 38.8 37.7 37.4 37.3 37.1 37.0 37.8 38.7 38.3 38.1 38.0 37.0 36.8 36.1 35.9 36.0 36.5 36.6 35.8 24.3 24.3 23.5 23.2 22.3 20.2 14.5 14.6 15.0 15.0 14.6 13.8 13.8 14.2 14.2 13.5
17.2 18.2 19.4 20.5 21.5 22.1 22.8 24.2 26.0 27.6 30.4 31.3 31.8 31.9 32.7 32.4 31.2 31.3 31.4 31.8 33.4 33.1 33.7 33.9 34.8 34.5 33.8 33.6 33.4 33.8 35.6 34.4 33.9 33.3 23.4 22.8 25.5 19.7 20.6 29.9 31.9 33.1 36.2 36.2 36.3 35.2 34.5 34.9 35.1 35.2 36.4 36.8 37.4 37.3 37.5 36.5 35.7 35.8 35.6 35.7 37.1 37.5 37.8 37.4 37.4 36.4 35.6 35.2 35.0 35.1 36.2 35.8 36.0 23.5 23.9 23.9 23.8 23.1 21.3 14.9 15.0 15.4 15.5 15.0 14.2 14.3 14.8 14.9 14.5 13.6 11.4 10.7
17.8 18.8 20.4 21.5 22.7 22.9 24.3 26.5 28.0 28.7 31.0 32.5 33.6 33.8 34.4 34.0 33.8 34.1 33.9 33.5 34.8 35.3 35.9 35.8 36.1 35.3 34.8 35.0 34.7 34.3 35.7 34.5 34.4 34.1 23.9 23.6 26.0 20.2 21.5 31.0 32.7 33.8 36.6 36.5 36.6 35.4 35.2 36.0 35.8 35.4 36.6 37.1 37.6 37.5 37.5 36.4 36.0 36.7 36.4 35.9 37.1 37.5 37.9 37.7 37.6 36.5 36.0 36.3 35.9 35.4 36.3 36.0 36.5 23.4 23.7 24.2 24.2 23.7 21.9 15.2 15.3 15.7 15.8 15.3 14.5 14.6 15.1 15.3 15.0 14.3 13.5 11.4
18.5 19.5 21.3 22.8 24.4 24.6 26.2 28.7 30.2 30.7 32.7 34.2 35.2 35.8 36.7 36.4 36.4 37.4 37.1 36.5 37.7 38.3 38.4 38.5 38.9 37.7 37.5 38.4 38.1 37.4 38.6 38.9 38.8 38.5 39.3 38.2 37.9 38.9 37.8 37.0 38.2 38.7 38.8 38.8 39.1 38.4 38.1 39.0 38.5 37.7 38.9 39.3 38.7 38.7 38.9 37.8 37.5 38.5 38.1 37.4 38.5 38.9 38.9 38.9 39.1 37.9 37.5 38.0 37.6 36.8 37.7 37.4 37.4 23.6 23.8 24.4 24.3 23.7 21.9 15.0 15.1 15.5 15.6 15.1 14.3 14.4 14.8 15.0 14.6 13.9 12.0 11.1
18.9 20.3 22.4 24.7 26.5 26.4 27.2 29.4 31.1 32.3 34.9 36.4 37.6 38.5 39.5 38.6 37.8 38.3 38.1 38.3 40.2 41.0 41.0 41.1 41.4 39.8 38.7 39.1 39.0 38.9 40.8 41.5 41.4 41.1 42.0 40.2 39.1 39.6 38.7 38.7 40.6 41.4 41.6 41.7 42.1 40.9 39.8 40.1 39.8 39.8 41.6 42.4 42.4 42.4 42.6 40.9 39.8 40.2 40.0 39.9 41.7 42.4 42.3 42.0 41.5 39.7 38.6 38.6 38.2 38.2 39.7 39.8 39.7 24.1 24.1 24.5 24.3 23.5 21.6 14.7 14.8 15.2 15.3 14.8 14.0 14.0 14.4 14.4 13.8 12.6 9.5 9.2
21.5 23.7 26.1 27.7 28.6 28.8 30.2 32.3 34.4 37.3 38.7 39.8 40.7 41.8 41.1 39.6 39.2 39.4 40.5 42.7 43.4 43.8 43.5 43.7 42.2 40.6 40.0 40.2 41.2 43.2 43.9 44.0 43.7 44.1 42.7 41.0 40.5 40.1 41.0 43.1 43.9 44.2 44.2 44.4 43.3 41.6 41.0 41.0 41.9 44.0 44.7 45.0 44.8 44.8 43.3 41.6 41.2 41.4 42.1 44.1 44.7 44.8 44.5 44.4 42.8 41.0 40.0 40.0 40.9 42.7 42.7 42.6 25.7 25.6 25.2 24.9 23.9 21.8 14.8 14.8 15.2 15.3 14.8 14.0 13.9 14.2 14.1 13.1
22.8 24.6 27.2 28.8 30.0 30.8 32.0 34.1 36.5 39.0 40.9 41.5 42.9 44.3 43.5 42.4 41.5 41.9 43.2 44.8 46.0 45.9 46.1 46.1 44.6 43.3 42.3 42.7 43.9 45.4 46.5 46.3 46.3 46.6 45.1 43.7 42.9 42.6 43.8 45.4 46.5 46.5 46.7 46.7 45.7 44.3 43.4 43.5 44.6 46.0 47.2 47.0 47.2 47.1 45.6 44.3 43.5 43.8 45.1 46.6 47.7 47.4 47.4 47.2 45.7 44.3 42.8 43.1 44.1 45.3 45.8 44.9 27.0 26.7 25.9 25.5 24.3 22.3 15.2 15.2 15.6 15.7 15.2 14.3 14.2 14.4 14.1 11.8
23.5 26.1 27.4 28.4 29.3 30.7 32.2 34.2 36.4 38.8 42.0 44.2 45.2 45.1 43.9 43.1 42.2 42.7 43.9 45.3 47.9 49.4 49.3 47.2 45.2 44.0 43.1 43.5 44.6 46.0 48.4 49.8 49.5 47.6 45.7 44.5 43.6 43.5 44.5 45.9 48.5 50.1 50.0 47.9 46.2 45.0 44.1 44.3 45.2 46.7 49.1 50.6 50.4 48.1 46.2 45.0 44.2 44.6 45.6 47.1 49.5 51.0 50.6 48.3 46.3 44.9 43.5 43.8 44.7 46.0 47.7 48.2 29.7 27.4 26.7 26.0 24.4 22.7 15.4 15.5 15.9 16.0 15.4 14.5 14.4 14.5 13.6 11.9
27.1 27.1 27.8 29.5 31.2 32.7 34.8 37.6 39.4 42.0 45.9 45.8 44.6 44.4 43.8 42.7 43.5 45.2 46.1 48.2 51.6 50.6 47.4 46.2 45.2 43.9 44.5 46.2 47.1 49.1 52.4 51.3 47.9 46.7 45.6 44.2 44.7 46.3 47.2 49.2 52.7 51.7 48.5 47.3 46.1 44.7 45.0 46.6 47.4 49.4 52.8 51.7 48.5 47.3 46.1 44.8 45.3 47.0 47.9 49.8 53.1 51.9 48.6 47.4 46.1 44.2 44.4 46.0 46.8 48.0 50.2 30.8 28.2 27.3 26.3 24.2 22.5 15.2 15.3 15.7 15.7 15.2 14.3 14.1 14.0 13.4 11.6
25.8 27.5 28.8 29.6 30.7 32.5 35.0 37.7 40.3 43.2 44.3 45.6 45.7 44.4 43.3 42.9 43.8 45.3 47.1 49.4 50.1 50.3 48.9 47.0 45.5 44.5 45.1 46.4 48.1 50.4 50.9 51.0 49.5 47.5 46.0 44.9 45.3 46.6 48.3 50.6 51.2 51.4 49.9 47.9 46.4 45.3 45.7 46.9 48.5 50.8 51.3 51.4 49.9 47.9 46.5 45.5 46.0 47.2 48.9 51.1 51.6 51.6 50.1 48.0 46.5 44.8 45.1 46.2 47.8 49.3 48.9 29.9 28.3 27.5 26.6 24.7 22.5 15.0 15.1 15.4 15.4 14.9 14.0 13.7 13.7 13.1 11.4
27.1 28.7 30.1 31.2 32.8 35.3 37.8 40.4 42.2 42.7 44.1 45.3 44.8 44.0 43.7 44.4 45.7 47.7 48.7 48.6 48.8 48.8 47.5 46.4 46.0 46.4 47.1 48.6 49.5 49.3 49.4 49.4 48.0 47.0 46.4 46.6 47.3 48.8 49.9 49.7 49.8 49.9 48.4 47.4 46.8 47.0 47.6 49.0 50.0 49.8 49.9 49.9 48.5 47.4 47.0 47.2 47.9 49.4 50.3 50.2 50.1 50.1 48.6 47.5 46.4 46.4 47.0 48.3 48.6 47.8 28.9 28.5 27.6 27.2 26.0 23.6 15.7 15.8 16.1 16.1 15.6 14.6 14.3 14.3 13.7 12.1
25.9 27.7 28.7 29.6 31.6 33.6 35.6 38.7 40.2 41.7 42.6 43.7 43.5 42.8 43.0 43.1 44.0 46.2 47.1 47.4 47.4 47.4 46.4 45.3 45.5 45.6 46.0 47.5 47.9 48.3 48.1 48.1 47.0 45.9 45.9 45.9 46.3 47.8 48.3 48.6 48.5 48.5 47.3 46.3 46.2 46.2 46.5 47.9 48.5 48.8 48.6 48.6 47.4 46.4 46.4 46.5 46.8 48.2 48.8 49.1 48.8 48.8 47.5 46.5 45.9 45.7 45.9 47.2 47.0 47.1 28.2 27.9 27.8 27.6 26.7 24.6 16.2 16.3 16.6 16.7 16.1 15.1 15.0 14.8 14.3 12.7
26.7 27.3 28.8 31.2 33.0 34.1 36.7 38.5 39.8 40.7 42.3 42.5 42.4 43.3 43.4 43.2 44.9 45.7 45.7 45.8 46.7 45.6 45.3 46.0 45.9 45.5 46.8 46.9 46.5 46.6 47.3 46.3 45.8 46.5 46.3 45.9 47.1 47.2 46.9 47.0 47.7 46.7 46.2 46.8 46.6 46.2 47.3 47.4 47.1 47.1 47.9 46.8 46.3 47.0 46.7 46.5 47.6 47.6 47.2 47.3 47.9 46.9 46.4 46.5 46.1 45.7 46.5 45.9 45.7 27.7 27.6 27.9 27.7 27.0 25.0 16.4 16.5 16.9 16.9 16.4 15.4 15.2 15.1 14.6 12.9
25.3 26.0 27.8 30.4 32.1 32.8 35.1 37.1 38.5 39.5 41.4 42.2 42.5 43.8 43.9 43.3 44.4 44.7 44.9 45.2 46.3 45.7 45.7 46.7 46.4 45.7 46.6 46.4 45.8 46.0 47.0 46.4 46.2 47.2 46.9 46.1 47.0 46.7 46.2 46.3 47.3 46.7 46.5 47.5 47.1 46.3 47.2 46.9 46.4 46.5 47.5 46.9 46.7 47.7 47.3 46.6 47.5 47.2 46.6 46.7 47.6 47.0 46.8 47.2 46.7 45.8 46.4 45.5 45.0 27.6 27.5 27.8 27.5 26.8 24.8 16.3 16.3 16.7 16.8 16.3 15.3 15.1 15.1 14.4 12.8
24.2 24.9 26.1 28.4 30.2 31.5 34.5 36.4 38.2 39.7 41.5 41.9 41.8 42.7 43.0 43.1 44.6 45.1 45.9 46.3 47.0 45.9 45.4 45.9 45.7 45.7 47.0 47.2 47.1 47.2 47.7 46.6 45.9 46.4 46.3 46.1 47.4 47.6 47.5 47.5 48.1 47.0 46.2 46.7 46.5 46.3 47.7 47.8 47.7 47.7 48.2 47.1 46.4 46.9 46.7 46.5 47.8 48.0 47.9 47.8 48.4 47.3 46.5 46.4 46.0 45.8 46.9 46.4 46.3 27.9 27.7 27.8 27.5 26.6 24.6 16.1 16.2 16.6 16.7 16.2 15.3 15.0 15.1 14.3 12.7
24.5 25.3 26.9 29.1 31.5 34.8 36.6 38.2 39.8 41.7 42.1 41.9 42.3 42.8 43.8 45.5 46.3 47.0 47.7 47.9 46.9 45.8 45.8 45.9 46.4 48.1 48.6 48.8 48.6 48.7 47.6 46.5 46.3 46.4 46.9 48.5 49.0 49.2 49.0 49.1 47.8 46.8 46.7 46.7 47.2 48.6 49.3 49.5 49.3 49.3 48.1 46.9 46.8 46.9 47.4 48.9 49.4 49.7 49.4 49.4 48.2 47.1 46.3 46.3 46.6 48.0 47.8 47.7 28.7 28.5 28.0 27.7 26.7 24.7 16.3 16.4 16.8 16.9 16.4 15.5 15.3 15.4 14.8 13.1
24.0 25.4 27.2 29.7 32.1 34.7 37.0 38.2 40.4 42.4 42.7 42.8 43.0 43.7 45.1 46.8 48.1 48.2 49.3 49.7 48.4 47.2 46.9 47.1 47.9 49.3 50.5 50.4 50.5 50.5 49.1 47.9 47.4 47.6 48.4 49.8 50.9 50.8 50.9 50.8 49.4 48.2 47.7 47.9 48.6 50.0 51.2 50.9 51.1 51.0 49.6 48.4 47.9 48.1 48.8 50.2 51.4 51.1 51.2 51.2 49.7 48.6 47.7 47.8 48.5 49.8 50.3 50.2 39.6 40.2 40.0 39.8 39.0 37.2 32.6 33.4 34.2 34.8 34.0 32.9 32.1 29.1 28.1 25.6
24.7 26.4 28.8 31.7 34.3 37.3 39.4 41.2 42.0 41.6 41.8 41.6 42.6 44.7 46.8 49.6 51.3 51.6 50.3 48.5 47.0 46.0 46.4 47.8 49.4 52.0 53.5 53.3 51.1 49.1 47.7 46.5 46.8 48.3 49.9 52.5 54.0 53.7 51.5 49.5 47.9 46.8 47.2 48.5 50.1 52.7 54.2 54.0 51.7 49.6 48.2 47.0 47.4 48.7 50.4 52.9 54.4 54.2 51.8 49.9 48.4 46.8 47.1 48.5 50.1 52.1 53.3 43.4 41.5 40.5 39.8 38.5 37.2 33.5 34.6 36.5 38.3 37.4 34.8 33.3 32.5 32.1 26.9
23.9 25.4 27.7 30.9 33.5 37.0 40.8 40.6 40.0 40.4 40.7 40.8 42.2 44.7 46.6 49.3 53.0 52.3 49.8 48.5 47.2 45.6 46.3 48.2 49.5 51.9 55.4 54.3 50.9 49.3 47.9 46.3 46.8 48.7 50.0 52.3 55.8 54.7 51.2 49.7 48.2 46.7 47.1 48.9 50.2 52.5 56.0 54.8 51.4 49.8 48.4 46.8 47.3 49.2 50.4 52.8 56.2 55.0 51.6 50.1 48.6 46.7 47.0 48.9 50.2 52.2 55.2 44.3 41.7 40.8 39.7 38.0 37.5 34.8 35.6 37.0 38.6 37.7 35.6 34.4 33.7 32.8 28.0 28.8
22.6 24.5 27.1 29.8 32.7 36.0 38.0 39.0 39.3 39.1 39.1 40.1 42.1 44.3 46.6 49.3 50.1 50.5 49.9 48.2 47.0 46.0 46.6 47.8 49.6 52.0 52.6 52.7 51.2 49.0 47.7 46.7 47.1 48.3 50.0 52.4 53.0 53.1 51.5 49.4 48.0 47.0 47.4 48.6 50.3 52.6 53.3 53.4 51.7 49.6 48.2 47.2 47.6 48.8 50.5 52.8 53.4 53.6 51.9 49.8 48.4 47.1 47.4 48.6 50.3 52.5 52.5 42.9 41.6 40.2 39.2 38.0 37.8 35.2 35.9 37.2 36.6 36.8 36.2 34.9 34.3 33.7 29.1 36.5
24.6 27.2 29.1 31.5 33.4 34.5 36.5 37.5 38.0 38.5 39.5 41.5 43.7 46.0 47.3 47.2 47.8 48.6 47.8 47.1 46.7 46.9 47.7 49.1 50.0 49.7 49.9 50.1 48.7 47.7 47.4 47.5 48.2 49.6 50.5 50.2 50.3 50.4 49.1 48.1 47.6 47.8 48.4 49.8 50.7 50.4 50.5 50.6 49.2 48.3 47.9 48.0 48.7 50.0 50.9 50.6 50.8 50.8 49.5 48.5 47.8 47.9 48.5 49.8 50.7 49.9 41.8 41.3 39.6 38.6 37.9 37.6 35.2 36.0 36.7 36.1 36.2 36.2 35.0 34.3 34.2 28.8 38.6
23.4 25.8 27.6 29.6 31.0 32.8 34.6 35.5 35.9 36.4 37.9 39.7 41.3 44.2 45.3 45.9 46.1 46.8 46.3 45.5 45.6 45.8 46.1 47.7 48.2 48.5 48.4 48.4 47.2 46.3 46.3 46.3 46.6 48.1 48.6 48.9 48.8 48.8 47.6 46.6 46.5 46.5 46.9 48.4 48.8 49.2 48.9 48.9 47.8 46.8 46.8 46.8 47.1 48.6 49.1 49.4 49.1 49.2 48.0 47.0 46.9 46.9 47.3 48.8 49.3 49.8 49.3 49.6 48.6 47.9 48.0 48.1 48.2 49.7 50.3 50.6 50.2 50.2 48.7 47.3 47.4 39.3 40.1
24.4 26.2 28.2 29.1 30.7 32.4 34.3 34.6 35.9 38.0 39.6 40.4 42.7 43.9 44.0 44.5 45.8 45.6 45.3 46.0 45.8 45.7 46.9 46.9 46.6 46.8 47.5 46.5 46.0 46.8 46.5 46.2 47.3 47.4 47.1 47.2 47.9 46.9 46.4 47.0 46.8 46.4 47.6 47.6 47.3 47.3 48.1 47.0 46.6 47.3 47.0 46.6 47.8 47.9 47.5 47.6 48.3 47.3 46.8 47.3 47.1 46.8 48.0 48.1 47.9 47.7 48.5 47.6 47.2 47.9 47.7 47.3 48.4 48.5 48.1 48.1 48.8 47.4 46.6 47.2 38.2 34.1
23.0 24.7 26.6 27.6 29.2 31.1 33.4 34.1 35.8 38.3 39.7 40.3 42.0 42.8 43.1 43.7 45.3 45.5 45.6 46.6 46.3 45.6 46.6 46.4 45.8 46.0 47.0 46.4 46.2 47.2 47.0 46.2 47.1 46.8 46.3 46.4 47.4 46.8 46.6 47.5 47.3 46.5 47.4 47.0 46.4 46.5 47.6 46.9 46.7 47.8 47.4 46.7 47.6 47.3 46.7 46.8 47.8 47.2 47.0 47.9 47.6 46.8 47.7 47.5 46.9 46.8 47.9 47.4 47.2 48.3 47.9 47.0 47.9 47.6 47.0 47.0 47.9 47.1 46.9 47.6 44.8 33.1
23.5 25.6 26.8 28.9 31.2 33.3 33.8 35.0 37.2 38.8 39.8 42.0 43.1 44.0 44.6 45.9 45.6 45.1 45.7 45.5 45.4 46.7 47.1 47.0 46.9 47.5 46.5 45.8 46.3 46.0 46.0 47.3 47.5 47.4 47.3 47.9 46.8 46.1 46.6 46.4 46.3 47.6 47.8 47.7 47.6 48.1 47.0 46.3 46.8 46.6 46.5 47.7 48.0 47.9 47.8 48.4 47.3 46.6 47.0 46.7 46.7 48.0 48.2 48.2 47.9 48.4 47.4 46.6 47.2 47.0 46.6 47.9 48.1 48.0 47.9 46.6 45.4 44.4 44.6 42.0 33.0
22.7 25.1 27.1 29.1 31.5 33.1 34.4 35.3 36.9 38.9 40.5 42.9 44.0 45.1 45.9 46.8 46.4 45.4 45.4 45.6 46.1 47.7 48.2 48.5 48.4 48.4 47.2 46.2 46.0 46.1 46.6 48.1 48.6 49.0 48.8 48.8 47.6 46.5 46.3 46.4 46.8 48.4 48.9 49.1 49.0 49.1 47.8 46.7 46.5 46.6 47.1 48.6 49.1 49.4 49.1 49.2 48.1 46.9 46.7 46.8 47.3 48.8 49.3 49.7 49.2 49.4 48.1 47.1 46.9 46.9 47.2 48.8 49.3 49.5 49.2 47.4 46.2 44.8 44.5 44.5 34.6
22.2 25.0 27.6 29.3 31.8 33.4 34.7 35.8 37.2 39.3 41.3 43.6 45.5 45.8 47.1 48.1 47.1 46.1 45.6 45.9 46.7 48.3 49.6 49.6 49.7 49.5 48.0 46.8 46.3 46.5 47.4 48.9 50.2 50.0 50.1 49.9 48.4 47.2 46.6 46.8 47.6 49.1 50.4 50.2 50.4 50.2 48.6 47.4 46.8 47.0 47.8 49.4 50.7 50.5 50.6 50.4 48.8 47.6 47.0 47.2 48.1 49.6 50.9 50.7 50.7 50.5 48.9 47.7 47.1 47.3 48.0 49.4 50.7 50.5 50.7 48.6 46.9 45.6 45.2 45.9 44.4
24.6 27.9 30.4 31.6 32.6 33.4 34.4 35.7 37.7 40.3 42.6 45.6 47.3 48.0 47.6 46.3 45.0 43.9 44.3 45.7 47.3 49.7 51.1 51.0 48.9 47.1 45.7 44.6 45.0 46.4 47.8 50.2 51.6 51.4 49.3 47.5 46.0 44.8 45.2 46.6 48.1 50.4 51.7 51.6 49.5 47.6 46.3 45.0 45.4 46.8 48.3 50.6 52.0 51.8 49.8 47.9 46.5 45.3 45.6 47.1 48.5 51.0 52.3 51.9 49.8 48.0 46.6 45.3 45.7 47.0 48.4 50.7 52.0 51.9 47.9 45.8 44.5 43.6 45.2
23.6 27.4 30.8 30.8 31.2 32.5 33.8 35.2 37.1 39.7 41.6 44.2 47.9 47.8 46.1 45.5 44.5 43.3 43.7 45.3 46.2 48.3 51.8 50.7 47.5 46.2 45.2 43.9 44.3 45.8 46.7 48.8 52.3 51.1 47.8 46.6 45.6 44.2 44.6 46.2 47.0 49.0 52.5 51.3 48.1 46.8 45.7 44.4 44.8 46.3 47.2 49.3 52.6 51.6 48.2 47.0 45.9 44.7 45.0 46.6 47.5 49.5 53.0 51.9 48.6 47.4 46.3 45.0 45.3 46.9 47.7 49.7 53.2 52.1 46.6 45.4 44.4 43.6 45.4 49.7 38.1 38.1 38.3 36.2 30.3 16.4
25.8 28.1 29.8 31.0 31.6 32.8 34.2 36.2 38.4 40.8 43.7 44.7 45.9 45.8 44.2 43.2 42.4 42.9 43.9 45.6 47.9 48.6 48.7 47.1 45.1 44.0 43.1 43.4 44.4 46.0 48.4 49.0 49.1 47.6 45.4 44.3 43.4 43.7 44.7 46.4 48.6 49.2 49.3 47.8 45.7 44.4 43.6 43.9 45.0 46.5 48.9 49.5 49.6 47.9 45.9 44.6 43.8 44.2 45.2 46.7 49.1 49.7 49.8 48.2 46.2 45.0 44.2 44.4 45.4 47.0 49.2 49.8 50.0 46.2 44.0 42.8 42.6 43.9 47.5 36.0 37.2 36.7 33.6 28.3 21.9
23.6 25.4 28.1 29.7 31.1 31.9 32.9 35.1 37.3 39.8 41.3 41.7 42.8 44.1 43.3 42.1 41.2 41.6 42.8 44.5 45.5 45.2 45.4 45.5 44.1 42.8 41.9 42.2 43.3 45.0 45.9 45.6 45.8 45.9 44.4 43.2 42.2 42.5 43.7 45.2 46.1 45.9 46.0 46.1 44.6 43.3 42.4 42.7 43.8 45.4 46.4 46.1 46.2 46.3 44.9 43.5 42.6 42.9 44.0 45.6 46.6 46.3 46.5 46.6 45.1 43.8 42.9 43.0 44.2 45.7 46.5 46.3 46.4 42.5 40.7 39.1 38.0 38.4 40.8 24.0 25.0 24.8 22.8 19.4 15.0
21.9 24.3 26.7 28.3 28.8 29.1 30.6 32.5 34.4 37.3 38.7 39.8 40.6 41.4 40.6 39.1 38.9 39.1 39.8 42.0 42.8 43.2 42.9 42.9 41.4 39.8 39.6 39.6 40.3 42.5 43.2 43.6 43.3 43.4 41.7 40.2 39.9 39.9 40.6 42.8 43.5 43.8 43.5 43.6 42.0 40.4 40.1 40.1 40.9 42.9 43.7 44.0 43.7 43.7 42.2 40.5 40.3 40.3 41.1 43.1 43.9 44.2 44.0 44.0 42.4 40.8 40.5 40.4 41.1 43.2 43.9 44.2 43.9 39.9 37.9 36.1 35.6 35.8 37.6 23.0 24.1 23.6 21.9 18.9 14.5
22.9 25.1 26.9 26.7 27.8 30.1 31.6 32.5 34.9 36.4 37.3 38.0 39.0 38.2 37.6 38.3 38.1 37.9 39.5 40.3 40.2 40.2 40.6 39.0 38.2 38.8 38.7 38.4 40.1 40.7 40.6 40.7 41.0 39.4 38.6 39.2 39.0 38.7 40.4 41.0 40.9 40.9 41.3 39.6 38.8 39.4 39.2 38.9 40.5 41.1 41.0 41.0 41.4 39.8 38.9 39.5 39.3 39.1 40.7 41.3 41.2 41.3 41.6 40.0 39.2 39.8 39.4 39.2 40.7 41.3 41.1 41.1 37.6 35.5 34.5 34.9 35.2 36.8 24.6 25.7 25.1 23.7 20.7 15.6
21.7 23.3 24.8 25.0 26.5 29.0 30.4 30.8 32.7 34.3 35.2 35.5 36.3 36.0 35.9 37.0 36.7 36.0 37.1 37.7 37.8 37.7 37.9 36.9 36.6 37.6 37.3 36.6 37.6 38.1 38.2 38.2 38.3 37.3 37.0 38.0 37.6 36.9 37.9 38.4 38.5 38.4 38.5 37.5 37.1 38.2 37.8 37.0 38.1 38.5 38.6 38.5 38.7 37.6 37.3 38.3 38.0 37.2 38.2 38.7 38.8 38.7 38.9 37.8 37.5 38.5 38.0 37.2 38.2 38.6 38.7 38.6 35.3 33.3 32.7 33.7 34.2 35.9 25.6 26.6 26.2 25.2 21.8 16.1
22.1 23.3 23.6 24.6 26.6 28.0 28.9 31.5 32.9 33.7 33.8 34.5 34.2 33.6 34.3 34.2 34.0 35.3 35.7 36.2 36.0 36.1 35.0 34.3 34.9 34.7 34.5 35.8 36.2 36.6 36.4 36.5 35.4 34.7 35.2 35.0 34.8 36.1 36.4 36.8 36.6 36.6 35.6 34.9 35.4 35.2 35.0 36.2 36.6 36.9 36.8 36.8 35.7 35.0 35.6 35.4 35.1 36.4 36.7 37.2 36.9 37.0 35.9 35.2 35.7 35.4 35.1 36.3 36.6 37.0 36.7 33.8 31.7 30.4 30.7 31.0 32.9 22.6 23.7 23.8 22.5 19.4 14.3
21.2 22.2 22.9 23.4 24.7 26.5 28.3 30.9 31.7 32.1 32.1 33.2 33.1 32.2 32.1 32.2 32.7 34.2 34.4 34.6 34.4 34.7 33.8 32.8 32.8 32.8 33.2 34.7 34.9 34.9 34.7 35.1 34.2 33.2 33.1 33.1 33.6 34.9 35.1 35.2 34.9 35.3 34.4 33.3 33.2 33.3 33.7 35.1 35.3 35.3 35.1 35.4 34.5 33.5 33.4 33.4 33.8 35.2 35.4 35.5 35.2 35.6 34.7 33.7 33.5 33.4 33.8 35.1 35.3 35.2 35.0 32.6 31.0 29.0 28.2 27.5
21.3 22.2 23.2 24.5 26.5 28.2 29.6 30.9 30.4 31.0 32.1 31.9 31.5 31.2 31.5 31.9 32.6 33.4 32.8 33.2 33.5 32.5 32.1 31.8 32.0 32.4 33.1 33.9 33.2 33.6 33.8 32.9 32.5 32.1 32.3 32.7 33.3 34.1 33.5 33.8 34.0 33.1 32.7 32.3 32.5 32.8 33.5 34.3 33.6 33.9 34.1 33.2 32.8 32.4 32.6 33.0 33.6 34.4 33.7 34.0 34.3 33.3 32.9 32.5 32.5 32.9 33.5 34.2 33.4 33.7 31.2 29.8 28.6 27.1 23.8
20.2 21.2 22.1 23.2 25.0 26.7 27.9 29.4 29.5 30.1 30.6 30.1 29.6 28.8 29.2 30.1 30.9 32.0 31.8 32.0 31.8 30.8 30.2 29.4 29.7 30.6 31.3 32.4 32.2 32.5 32.1 31.2 30.6 29.6 30.0 30.9 31.6 32.7 32.5 32.7 32.3 31.4 30.8 29.8 30.2 31.0 31.7 32.8 32.6 32.8 32.4 31.5 30.8 29.9 30.2 31.1 31.8 32.9 32.7 32.9 32.5 31.5 30.9 29.9 30.2 31.0 31.7 32.7 32.4 30.6 29.5 28.1 26.4 24.3 22.6
18.7 19.9 20.9 21.8 22.9 24.4 25.6 27.1 29.3 29.3 28.2 27.7 27.1 26.4 26.7 27.6 28.3 29.6 31.6 31.0 29.1 28.4 27.7 27.0 27.2 28.1 28.8 30.0 32.0 31.4 29.5 28.7 28.1 27.4 27.6 28.4 29.1 30.3 32.2 31.7 29.7 28.9 28.2 27.5 27.7 28.6 29.2 30.4 32.3 31.7 29.8 29.0 28.3 27.5 27.8 28.6 29.2 30.5 32.4 31.8 29.8 29.0 28.3 27.6 27.6 28.5 29.1 30.2 32.1 29.5 26.9 25.5 24.1 22.5 21.3
18.6 19.2 20.0 20.8 21.9 23.4 25.0 26.5 26.9 26.2 25.2 24.4 24.2 24.4 25.0 26.0 27.4 28.7 28.3 26.9 25.9 25.0 24.8 24.9 25.5 26.5 27.8 29.1 28.8 27.4 26.2 25.4 25.2 25.2 25.8 26.9 28.1 29.3 29.0 27.6 26.5 25.6 25.3 25.4 25.9 26.9 28.2 29.4 29.0 27.6 26.5 25.6 25.3 25.4 25.9 27.0 28.2 29.4 29.1 27.6 26.5 25.6 25.3 25.2 25.8 26.8 28.0 29.1 26.8 24.8 23.2 21.6 20.6 19.5
0.1 0.1 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.6 0.7 0.9 1.2 1.6 2.1 2.8
0.2 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.6 0.7 1.0 1.3 1.7 2.2 3.0
0.2 0.2 0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.8 1.0 1.3 1.7 2.3 3.1
0.2 0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.8 1.0 1.3 1.7 2.3 3.1 4.2
0.2 0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.8 1.0 1.3 1.7 2.3 3.0 4.0
0.2 0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.8 1.0 1.3 1.6 2.2 2.9 3.8
0.2 0.2 0.3 0.3 0.4 0.5 0.6 0.8 1.0 1.2 1.6 2.1 2.7 3.5
0.2 0.2 0.3 0.3 0.4 0.4 0.6 0.7 0.9 1.2 1.5 2.0 2.6 3.3 4.3
0.2 0.3 0.3 0.3 0.4 0.5 0.7 0.8 1.1 1.5 1.9 2.4 3.2 4.1
0.2 0.3 0.3 0.3 0.4 0.5 0.6 0.8 1.0 1.3 1.8 2.3 3.0 4.0
0.3 0.3 0.3 0.3 0.4 0.5 0.6 0.7 0.9 1.2 1.6 2.2 2.9 3.8
0.3 0.3 0.3 0.4 0.4 0.6 0.7 0.9 1.1 1.4 1.9 2.7 3.6
0.3 0.3 0.3 0.4 0.4 0.5 0.7 0.8 1.0 1.3 1.7 2.2 3.0 4.4
0.1 0.1 0.1 0.2 0.2 0.2 0.3 0.4 0.5 0.6 0.7 0.9 1.9 4.0
0.1 0.2 0.2 0.2 0.2 0.3 0.4 0.5 0.7 0.9 1.5 2.6 3.6
0.2 0.2 0.2 0.2 0.3 0.3 0.5 0.6 0.9 1.1 1.9 2.5 3.3
0.2 0.2 0.2 0.3 0.4 0.5 0.7 0.9 1.4 1.8 2.4 3.2
0.2 0.2 0.3 0.3 0.4 0.6 0.7 1.0 1.4 1.8 2.3 3.0 3.9
0.2 0.3 0.3 0.4 0.4 0.6 0.8 1.0 1.3 1.7 2.2 2.9 3.7
0.3 0.3 0.4 0.5 0.6 0.8 1.0 1.3 1.6 2.1 2.7 3.5
0.3 0.3 0.4 0.5 0.6 0.8 1.0 1.2 1.6 2.0 2.6 3.4
0.4 0.4 0.5 0.6 0.7 0.9 1.2 1.5 2.0 2.6 3.3 4.2
0.4 0.4 0.5 0.6 0.7 0.9 1.2 1.5 1.9 2.5 3.2 4.2
0.4 0.5 0.6 0.7 0.9 1.1 1.4 1.9 2.5 3.2 4.2
0.4 0.5 0.5 0.7 0.8 1.1 1.4 1.8 2.4 3.2 4.1
0.4 0.5 0.5 0.6 0.8 1.0 1.3 1.7 2.3 3.0 3.9
0.4 0.5 0.6 0.8 1.0 1.3 1.7 2.2 2.8 3.6 4.5
EM
EM
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
11 11
10 10
12 12
G G
B B
C C
D D
E E
STEM
CLASSROOM
113
STEM
CLASSROOM
112
MEN'S
RESTROOM
106
MECHANICAL
ROOM
103
ELECTRICAL
ROOM
104
IDF
ROOM
105
FAMILY
RESTROOM
108
NURSING
ROOM
116
WOMEN'S
RESTROOM
107
EXHIBIT
SPACE
100
STORAGE
101
ELEVATOR
111
ELEVATOR
MACHINE
ROOM
110
(TYP.)
R1
(TYP.)
S1
ZR1-18
ZR1-14
ZR1-12
ZR1-8R3-16
R3-16
R3-20
R3-16
R3-20
R3-20
STAFF
RESTROOM
114
XW1XM1
ZW1-T3
STAFF
ROOM
102
W1-4
(TYP.)
P3
(TYP.)
P3
ZW1-T3
C1
C1
W3-6DI W3-6DI
R4
(TYP.)
R1
XW1
(TYP.)
W1-4
C1
(TYP.)
W2-4
ZW1-T3W5-5DI
W5-5DI
R1
ZW1-T3 ZW1-T3 ZW1-T3 ZW1-T3
ZW1-T3
4 LIGHTING ILLUMINANCE (FC) SUMMARY
LEGEND OF REFLECTANCES
SURFACE REFLECTANCES ARE ASSUMED STANDARDS USED IN CALCULATION MODEL.
GENERAL
CEILING
WALLS
FLOOR
70%
50%
20%
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
LIGHTING FIRST
FLOOR
PHOTOMETRIC
E9.03
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
Label LLF
EXHIBIT SPACE 100 0.9
STORAGE 101
STAFF ROOM 102
MECHANICAL ROOM 103
ELECTRICAL ROOM 104
IDF ROOM 105
MEN'S RESTROOM 106
WOMEN'S RESTROOM 107
FAMILY RESTROOM 108
STAFF RESTROOM 114
0.9 0.9
0.9 0.9
0.9 0.9
0.9 0.9
0.9 NOTE:
THIS LIGHTING CALCULATION REPRESENTS ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA TAKEN UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY (IES) APPROVED METHODS.
Avg
36.7 fc
30.2 fc
36.6 fc
16.4 fc
35.9 fc
42.3 fc
24.9 fc
21.0 fc
14.7 fc
15.1 fc
Max
55.9 fc
47.3 fc
47.7 fc
24.0 fc
45.5 fc
48.8 fc
41.2 fc
32.2 fc
20.4 fc
20.7 fc
Min
8.0 5.8 fc
17.9 fc
9.4 fc
23.0 fc
16.0 fc
11.4 fc
11.4 fc
9.5 fc
10.0 fc
Max/Min
6.9:1
8.1:1
2.6:1
2.5:1
1.9:1
1.6:1
3.6:1
2.8:1
2.1:1
2:1
Workplane Height
0 ft
2.5 ft
2.5 ft
0 ft
0 ft
0 ft
0 ft
0 ft
0 ft
0 ft
FIRE RISER 0.9
ELEVATOR MACHINE ROOM 110 0.9
17.0 fc
9.4 fc
18.5 fc
11.3 fc
16.0 fc
7.4 fc
1.1:1
1.5:1
0 ft
0 ft
STEM CLASSROOM 112 0.9
STEM CLASSROOM 113 0.9
39.1 fc
35.0 fc
58.0 fc
52.7 fc
13.1 fc
9.9 fc
4.4:1
5.3:1
2.5 ft
2.5 ft
ELEVATOR PIT 0.9 24.1 fc 38.7 fc 13.1 fc 2.9:1 0 ft
NURSING ROOM 116 0.9 37.7 fc 43.9 fc 28.4 fc 1.5:1 2.5 ft JANITOR 0.9 22.0 fc 26.4 fc 18.6 fc 1.4:1 2.5 ft
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
REF.TVTVCGLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDLEDEM EM
EM
EM
EM
EM
EM
EM
EM
EM
EMEMEMEM
EM
EM EM
EMEM
EM EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
3.4 3.7 3.7 3.5 3.2 2.8 2.5
4.7 5.0 5.0 4.6 4.0 3.5 3.0
6.8 7.3 7.1 6.3 5.3 4.4 3.7
10.1 10.8 10.3 8.8 7.1 5.5 4.4
14.3 15.3 14.6 12.0 9.0 6.6 5.1
19.0 19.6 18.9 14.7 10.4 7.4 5.6
20.7 20.7 19.8 15.2 10.7 7.6 5.7
18.1 18.4 16.9 13.4 9.8 7.1 5.4
13.7 14.5 13.2 10.7 8.2 6.2 4.7
16.7 18.3 17.5
21.3 22.8 22.4
24.3 25.2 24.8
22.8 23.7 22.5
18.2 19.6 18.3
9.5 12.1 15.0 16.4
10.8 14.1 17.7 19.8
11.0 14.4 18.1 20.3
9.9 12.8 15.9 17.6
17.2 18.6 17.0
16.1 17.7 16.1
5.4 7.2 10.1 13.9 17.3 18.7 18.1
6.0 8.0 11.4 16.1 20.6 21.4 21.2
6.0 8.0 11.3 15.8 20.1 21.1 19.7
5.6 7.2 9.8 13.0 15.7 16.3 15.2
4.9 6.1 7.8 9.8 11.3 11.8 10.9
4.1 5.0 6.0 7.2 8.0 8.2 7.6
3.4 4.1 4.8 5.4 5.9 5.9 5.4
3.0 4.5 4.3 3.2
4.3 5.9 6.0 5.0
5.8 7.7 7.8 6.7
7.6 9.6 9.7 8.3
9.1 11.1 11.3 9.7
10.3 11.7 12.1 10.3
10.3 11.8 9.2 11.5 11.5 11.9 10.1
10.5 12.3 13.2 12.7 11.7 11.8 10.1
9.7 9.6 11.2 13.1 11.7 11.2 9.4
7.1 12.8 12.6 9.5 9.4
7.2 11.1 13.0 10.1 9.1
8.2 11.9 12.5 12.5 9.1
9.5 12.7 13.4 12.9 10.8
10.2 12.8 13.7 12.6 10.9
10.0 12.3 13.0 12.0 10.1
9.7 11.8 10.2 11.7 11.0 10.2 8.3
5.4 4.9 3.9 3.9 6.1 11.9 19.0 17.4 10.3 6.7 8.0 14.2 20.3 16.0
10.3 11.8 9.2 5.8 4.6 6.4 11.9 18.4 17.0 10.1 6.7 7.9 14.1 19.7 15.7
15.9 20.3 14.2 7.5 4.7 4.9 8.1 10.6 10.0 7.0 3.7 2.2 8.8 11.0 9.2
15.4 19.6 13.8 4.8 4.5 10.2 11.5 10.4 4.3 5.1 4.5
2.1 2.2 12.8 19.5 17.3 2.2 2.4 2.2
1.0 1.2 11.9 18.9 16.8 1.4 1.4 1.3
19.3 24.0 26.6 26.4 25.3 25.8 27.6 28.6 27.4 25.7 25.4 26.3 26.1 22.8 18.0
23.8 30.3 34.1 33.0 30.7 31.2 34.5 36.4 34.2 31.1 30.7 33.1 33.3 28.7 22.4
27.1 34.6 39.1 37.7 34.6 35.3 39.3 41.8 39.0 35.1 34.9 37.8 38.4 33.0 25.4
28.2 35.5 40.5 39.0 36.4 37.1 40.9 43.2 40.6 36.9 36.6 38.9 39.3 34.1 26.6
28.7 35.8 40.8 39.8 37.6 38.1 41.4 43.2 41.0 37.9 37.5 39.3 39.3 34.3 27.3
29.8 39.2 43.4 41.8 39.0 39.6 43.4 45.5 42.9 39.2 38.9 41.2 41.5 36.0 28.3
30.5 41.4 45.2 43.1 40.0 40.5 44.7 47.1 44.1 40.0 39.6 42.3 42.9 37.1 28.8
29.6 35.2 34.7 31.0 27.9 25.2 37.4 42.4 44.8 42.7 39.5 40.0 43.7 45.7 43.1 39.3 38.6 41.1 41.3 36.1 28.5
32.7 41.0 40.9 37.9 38.3 37.5 39.4 42.3 43.8 41.8 38.9 39.2 42.2 43.7 41.6 38.2 37.3 39.4 39.5 34.9 27.9
26.5 31.0 29.8 42.0 43.1 42.2 41.5 43.6 44.9 42.2 38.4 38.4 42.0 43.9 41.3 37.3 36.6 39.2 40.0 35.0 27.6
31.9 42.6 42.0 40.6 42.7 44.0 40.9 36.9 36.5 40.3 42.5 39.6 35.5 34.8 37.5 39.1 34.1 26.1
27.6 32.4 34.9 35.6 37.2 38.0 35.7 32.3 32.2 35.0 36.5 34.4 31.3 30.7 32.8 33.7 30.2
16.9 15.6 12.8 10.1
20.4 18.3 14.8 11.5
20.8 18.6 14.9 11.5
17.7 16.2 13.2 10.2
1.3 1.4 1.4 1.3 1.2 1.1
1.5 1.6 1.6 1.6 1.6 1.3
1.7 1.8 1.9 1.9 2.0 2.0
2.0 2.1 2.2 2.3 2.3 2.4 2.6 2.8 3.0 3.3 3.7 4.1 4.5 5.0 5.5 5.9 6.2 6.2 6.0 5.6 5.0
2.2 2.5 2.4 2.5 2.6 2.7 2.7 2.8 3.0 3.2 3.4 3.7 4.1 4.6 5.3 6.0 6.7 7.4 7.8 7.8 7.5 6.9 6.1
2.9 2.9 3.0 3.1 3.2 3.2 3.3 3.4 3.6 3.8 4.1 4.6 5.3 6.2 7.2 8.4 9.4 10.0 10.1 9.6 8.7 7.6
3.4 3.5 3.7 3.8 3.8 3.8 3.9 3.9 4.0 4.2 4.6 5.2 6.0 7.2 8.7 10.4 12.0 13.0 13.2 12.5 11.1 9.4
4.1 4.4 4.6 4.7 4.7 4.7 4.6 4.5 4.5 4.7 5.0 5.7 6.7 8.2 10.2 12.6 15.0 16.5 16.8 15.7 13.7 11.4
5.1 5.6 5.9 6.0 5.9 5.8 5.5 5.3 5.1 5.2 5.5 6.1 7.2 8.9 11.4 14.4 17.4 19.4 19.7 18.4 15.9 12.9
6.4 7.2 7.6 7.7 7.6 7.2 6.7 6.2 5.8 5.7 5.9 6.5 7.6 9.4 12.0 15.3 18.5 20.8 21.1 19.6 16.9 13.6
8.1 9.2 9.9 10.1 9.8 9.1 8.1 7.2 6.6 6.2 6.2 6.7 7.7 9.4 11.9 15.1 18.3 20.4 20.7 19.2 16.5 13.4
10.2 11.9 13.0 13.3 12.7 11.5 9.9 8.4 7.3 6.6 6.4 6.7 7.5 9.0 11.1 13.8 16.5 18.3 18.6 17.3 14.9 12.1
12.3 14.7 16.4 16.8 15.9 14.1 11.7 9.6 8.0 7.0 6.5 6.6 7.2 8.3 9.9 11.9 13.8 15.1 15.3 14.3 12.5 10.3
14.0 17.0 19.1 19.7 18.5 16.1 13.2 10.5 8.5 7.2 6.5 6.4 6.7 7.4 8.5 9.8 11.0 11.7 11.8 11.1 9.9 8.3
14.8 18.0 20.3 20.9 19.7 17.0 13.7 10.8 8.6 7.2 6.4 6.0 6.2 6.5 7.2 8.0 8.7 9.1 9.1 8.6 7.8 6.7
14.5 17.6 19.8 20.4 19.2 16.6 13.5 10.6 8.5 7.0 6.1 5.6 5.6 5.8 6.2 6.6 7.0 7.2 7.1 6.8 6.2 5.4
13.1 15.7 17.6 18.1 17.2 15.0 12.3 9.9 7.9 6.5 5.6 5.2 5.1 5.1 5.3 5.6 5.8 5.8 5.7 5.5 5.1 4.5