10.8 12.8 14.3 14.7 14.0 12.5 10.5
2.8 6.4 8.4 9.9 10.9 11.2 10.7 9.6 8.3
4.2 5.4 6.5 7.5 8.1 8.3 8.0 7.4 6.5
3.7 4.4 5.1 5.7 6.1 6.2 6.1 5.7 5.1
3.1 3.6 4.1 4.4 4.7 4.7 4.6 4.4 4.0
2.6 3.0 3.3 3.5 3.7 3.7 3.7 3.5 3.2
2.2 2.5 2.7 2.9 3.0 3.0 3.0 2.8 2.6
1.9 2.1 2.3 2.4 2.5 2.5 2.5 2.4 2.1
18.2 17.5 20.1 18.8 17.2 1.3 1.4 1.2
14.7 19.6 14.2 18.9 18.1 20.6 19.5 17.8 2.1 2.4 2.2
15.3 20.4 14.5 7.2 3.0 1.5 11.5 11.1 13.7 11.7 10.9 4.2 4.9 4.4
9.9 11.8 9.2 5.6 4.0 4.8 11.0 9.8 6.7 3.6 2.2 8.5 10.7 9.1
5.3 4.8 3.8 3.9 6.5 12.9 19.1 16.0 9.3 6.3 7.8 13.8 19.4 15.6
2.5 2.6 2.6 3.5 6.6 13.2 20.1 16.8 9.6 6.4 8.0 14.3 20.6 16.3 EM
EM
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
11 11
10 10
12 12
G G
B B
C C
D D
E E
STEM
CLASSROOM
113
STEM
CLASSROOM
112
MEN'S
RESTROOM
106
MECHANICAL
ROOM
103
ELECTRICAL
ROOM
104
IDF
ROOM
105
FAMILY
RESTROOM
108
NURSING
ROOM
116
WOMEN'S
RESTROOM
107
EXHIBIT
SPACE
100
STORAGE
101
ELEVATOR
111
ELEVATOR
MACHINE
ROOM
110
(TYP.)
R1
(TYP.)
S1
ZR1-18
ZR1-14
ZR1-12
ZR1-8R3-16
R3-16
R3-20
R3-16
R3-20
R3-20
STAFF
RESTROOM
114
XW1XM1
ZW1-T3
STAFF
ROOM
102
W1-4
(TYP.)
P3
(TYP.)
P3
ZW1-T3
C1
C1
W3-6DI W3-6DI
R4
(TYP.)
R1
XW1
(TYP.)
W1-4
C1
(TYP.)
W2-4
ZW1-T3W5-5DI
W5-5DI
R1
ZW1-T3 ZW1-T3 ZW1-T3 ZW1-T3
ZW1-T3
4 LIGHTING ILLUMINANCE (FC) SUMMARY
LEGEND OF REFLECTANCES
SURFACE REFLECTANCES ARE ASSUMED STANDARDS USED IN CALCULATION MODEL.
GENERAL
CEILING
WALLS
FLOOR
70%
50%
20%
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
LIGHTING FIRST
FLOOR
EMERGENCY
PHOTOMETRIC
E9.04
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
Label LLF Avg Max Min Max/Min
EXHIBIT SPACE 100 0.9 6.6 fc 20.6 fc 0.6 34.3:1
STORAGE 101 8.0 fc 21.1 fc 1.1 fc 19.1:1
STAFF ROOM 102 6.0 fc 17.0 fc 1.3 fc 13:1
MECHANICAL ROOM 103 8.6 fc 12.5 fc 1.7 fc 7.3:1
ELECTRICAL ROOM 104 9.3 fc 20.8 fc 2.5 fc 8.3:1
IDF ROOM 105 10.7 fc 21.5 fc 3.5 fc 6.1:1
MEN'S RESTROOM 106 9.5 fc 20.4 fc 1.1 fc 18.5:1
WOMEN'S RESTROOM 107 10.4 fc 1.3 fc 8.0 fc 15.9:1
FAMILY RESTROOM 108 14.8 fc 20.5 fc 9.8 fc 2:1
STAFF RESTROOM 114 15.1 fc 20.6 fc 10.1 fc 2:1
FIRE RISER 17.2 fc 19.2 fc 15.9 fc 1.2:1
0.9 0.9
0.9 0.9
0.9 0.9
0.9 0.9
0.9 0.9
ELEVATOR MACHINE ROOM 110 21.3 fc 25.2 fc 16.7 fc 1.5:10.9 NOTE:
THIS LIGHTING CALCULATION REPRESENTS ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA TAKEN UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY (IES) APPROVED METHODS.
STEM CLASSROOM 112 12.2 fc 25.0 fc 2.9 fc 8.6:10.9
STEM CLASSROOM 113 10.6 fc 22.2 fc 2.3 fc 9.6:10.9
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
EMEM
EM EM
EM
EM
EM
EM
EM EM
13.4 14.8 17.7 16.9 16.1 17.1 17.2 17.2 17.3 16.6 16.5 17.4 18.1 14.4 15.0 16.7 19.6 19.1 16.9 15.6 15.4 15.5 15.4 16.1 18.2 19.4 19.9 16.4 13.0 14.8 17.7 16.9 16.1 16.9 17.0 16.9 16.9 15.1 14.3 14.4 14.2 13.5 12.1
25.6 23.7 23.2 22.7 21.3 22.0 21.3 19.7 19.5 20.2 22.4 21.4 22.0 23.3 23.1 25.4 24.8 23.7 22.8 22.6 22.7 20.3 19.4 19.6 19.2 22.1 22.7 22.6 23.4 24.3 25.8 23.8 23.4 22.8 21.3 22.1 21.2 19.6 19.3 19.7 20.3 18.7 18.5 18.4 17.3 15.3
32.1 33.4 31.3 30.3 30.2 30.4 26.5 23.3 23.2 24.2 29.1 31.0 30.1 31.0 32.6 33.6 30.9 28.8 27.7 27.4 29.5 29.4 26.3 26.2 27.4 30.5 28.4 27.5 28.3 29.6 32.4 33.7 31.6 30.5 30.5 30.4 26.4 23.3 23.0 23.6 26.0 27.4 25.3 25.0 23.9 21.4
38.4 40.2 39.7 38.3 39.9 37.8 34.0 29.4 28.3 30.6 36.3 39.0 39.4 38.6 41.0 39.7 37.7 36.0 34.7 36.1 36.8 37.1 33.7 32.3 35.0 37.5 36.5 35.5 34.9 37.1 38.7 40.7 40.0 38.4 40.1 37.9 33.9 29.4 28.2 30.4 32.0 33.7 33.0 31.0 30.1 27.0
42.2 40.4 40.1 38.8 39.7 40.5 39.4 35.6 36.0 36.8 41.1 39.8 40.1 39.1 40.5 41.6 42.3 40.6 40.9 40.8 41.6 37.9 35.6 34.4 36.2 40.2 41.6 40.5 41.1 41.4 42.8 40.7 40.4 39.2 39.8 40.6 39.4 35.7 36.1 36.3 37.4 35.2 34.9 32.1 30.6 30.2
40.5 41.8 41.9 41.6 41.6 40.8 40.7 42.1 42.5 41.8 40.0 41.5 41.9 42.0 42.2 41.6 42.5 44.7 45.0 43.8 40.4 40.6 39.7 39.6 40.0 40.9 41.9 44.6 45.2 44.4 40.9 42.2 42.3 42.0 41.7 40.9 40.7 42.2 42.6 41.6 37.8 39.0 39.1 36.3 34.6 31.8
42.6 42.2 38.9 38.6 40.6 42.2 41.6 46.8 47.0 43.3 42.5 42.1 38.9 39.0 41.1 42.8 42.4 48.1 48.1 44.2 42.8 42.1 38.2 38.1 40.2 42.6 42.2 47.8 48.1 44.4 43.2 42.6 39.2 38.9 41.0 42.3 41.7 47.0 47.2 43.3 41.6 41.2 37.7 34.3 35.1 34.1
43.7 41.3 38.8 41.9 38.1 43.4 43.9 48.3 49.8 44.6 43.8 41.4 39.1 42.2 38.5 43.8 44.3 49.0 50.4 45.0 44.0 41.4 38.9 41.9 38.2 43.8 44.3 49.1 50.6 45.3 44.3 41.8 39.4 42.3 38.5 43.8 44.0 48.5 50.0 44.6 43.6 40.9 38.1 37.8 33.0 35.6
47.1 44.6 42.0 45.1 41.3 47.0 46.9 50.3 51.2 47.2 47.3 44.8 42.2 45.4 41.7 47.4 47.5 50.6 51.4 47.6 47.4 44.8 42.2 45.3 41.6 47.3 47.4 50.7 51.6 47.6 47.6 45.1 42.5 45.4 41.7 47.2 47.2 50.3 51.2 47.2 47.2 44.6 41.5 41.2 36.3 39.1
47.2 47.0 43.8 43.7 45.7 47.3 46.9 54.0 55.1 49.4 47.6 47.3 44.1 44.0 46.0 47.6 47.2 54.3 55.3 49.8 47.8 47.4 44.1 44.0 46.1 47.6 47.4 54.5 55.5 49.8 47.8 47.6 44.3 44.0 46.1 47.4 47.1 54.0 55.1 49.4 47.4 47.1 43.7 40.2 40.8 39.6
46.8 47.3 47.9 48.0 47.8 46.9 49.5 52.7 53.0 52.3 47.1 47.6 48.2 48.2 48.1 47.2 49.8 53.2 53.5 52.6 47.3 47.9 48.3 48.3 48.1 47.4 50.0 53.1 53.5 52.5 47.3 47.9 48.5 48.4 48.2 47.3 49.7 53.0 53.3 52.1 47.1 47.4 47.9 45.1 42.9 39.3
51.8 48.2 48.1 47.2 47.9 50.4 51.4 49.1 49.3 50.1 52.1 48.5 48.5 47.5 48.0 50.8 51.7 49.4 49.6 50.3 52.4 48.7 48.5 47.6 48.2 50.9 51.9 49.6 49.8 50.5 52.4 48.7 48.6 47.7 48.1 50.8 51.8 49.2 49.3 50.1 52.1 48.2 48.0 45.3 43.0 41.1
52.1 55.6 53.3 51.9 55.3 54.6 50.2 47.0 45.6 48.6 52.4 55.9 53.7 52.2 55.6 54.9 50.5 47.3 45.9 48.9 52.7 56.0 53.9 52.4 55.7 54.9 50.7 47.2 45.8 48.8 52.7 56.2 54.0 52.3 55.7 55.0 50.6 47.1 45.7 48.7 52.5 55.7 53.2 51.1 49.5 44.4
52.5 55.8 53.5 52.1 55.5 54.7 50.6 47.1 45.8 48.8 52.6 56.1 53.9 52.4 55.8 55.1 50.9 47.4 46.1 49.1 52.9 56.4 54.1 52.7 56.0 55.3 50.9 47.7 46.3 49.1 53.1 56.4 54.2 52.7 55.9 55.1 50.7 47.2 45.9 48.9 52.7 55.8 53.4 51.3 49.6 44.5
52.5 49.0 48.7 47.8 48.5 51.3 52.1 49.8 50.0 50.8 52.9 49.3 49.1 48.1 48.9 51.6 52.4 50.2 50.3 51.1 53.0 49.6 49.2 48.3 48.9 51.6 52.4 50.4 50.5 51.1 53.2 49.6 49.4 48.3 49.0 51.8 52.6 49.9 50.1 50.9 52.7 49.1 48.7 45.7 43.5 41.6
47.9 48.5 49.1 49.1 49.0 48.1 50.7 53.9 54.3 53.4 48.3 48.8 49.4 49.5 49.3 48.4 51.0 54.3 54.6 53.7 48.6 49.1 49.5 49.6 49.4 48.7 51.2 54.2 54.6 53.7 48.6 49.1 49.8 49.5 49.4 48.5 51.2 54.1 54.5 53.6 48.2 48.6 49.1 46.2 43.8 40.3
48.8 48.6 45.5 45.4 47.4 48.8 48.6 55.7 56.8 51.1 49.1 49.0 45.9 45.8 47.8 49.2 48.8 56.1 57.1 51.5 49.4 49.3 46.0 45.9 48.0 49.4 49.0 56.3 57.1 51.7 49.7 49.3 46.1 46.0 47.8 49.3 48.9 55.9 57.0 51.4 49.3 48.8 45.4 41.8 42.5 40.8
49.3 47.2 44.9 48.0 44.2 49.5 49.3 52.6 53.5 49.6 49.6 47.6 45.2 48.4 44.6 49.7 49.7 53.0 53.9 49.9 49.8 47.7 45.5 48.6 44.9 50.0 49.7 53.0 53.9 49.9 50.0 48.0 45.5 48.7 44.9 49.8 49.6 52.9 53.6 49.6 49.7 47.3 44.5 44.2 39.2 41.4
49.3 47.3 45.1 48.2 44.4 49.6 49.3 52.6 53.5 49.6 49.7 47.6 45.4 48.6 44.7 49.9 49.7 53.0 53.9 49.9 50.0 47.9 45.7 48.9 45.0 50.1 49.9 53.2 53.9 50.0 50.1 48.0 45.8 48.8 44.9 50.2 49.6 52.9 53.6 49.6 49.7 47.5 44.6 44.4 39.2 41.4
49.2 48.9 45.7 45.6 47.8 49.3 48.9 56.0 57.1 51.6 49.6 49.3 46.1 46.0 48.0 49.5 49.3 56.4 57.4 51.8 49.8 49.6 46.3 46.2 48.3 49.8 49.4 56.6 57.5 52.0 49.8 49.7 46.4 46.3 48.2 49.7 49.3 56.3 57.1 51.7 49.4 49.1 45.6 42.1 42.5 41.1
48.4 49.0 49.6 49.6 49.5 48.7 51.2 54.6 55.0 54.0 48.8 49.4 50.0 50.0 49.9 49.0 51.6 54.7 55.1 54.2 49.2 49.6 50.2 50.2 50.0 49.1 51.7 55.0 55.4 54.4 49.2 49.6 50.3 50.3 49.9 49.1 51.6 54.7 55.1 54.1 48.8 49.1 49.5 46.4 44.3 40.6
53.2 49.6 49.4 48.5 49.2 51.9 52.9 50.6 50.8 51.6 53.6 50.0 49.8 48.9 49.6 52.3 53.3 51.0 51.2 52.0 53.8 50.3 50.2 49.2 49.9 52.4 53.3 51.0 51.2 52.0 54.0 50.4 50.1 49.2 49.8 52.3 53.2 50.9 51.1 51.6 53.6 49.7 49.3 46.6 44.1 42.1
53.4 56.8 54.6 53.1 56.4 55.8 51.5 48.1 46.8 49.7 53.8 57.1 55.0 53.5 56.8 56.0 51.9 48.5 47.1 50.1 53.9 57.4 55.1 53.6 57.0 56.3 51.9 48.7 47.4 50.1 54.2 57.5 55.2 53.7 56.9 56.2 51.8 48.4 47.0 49.7 53.7 56.9 54.4 52.0 50.3 45.1
57.4 55.1 53.7 57.1 56.3 52.0 48.7 47.4 50.1 54.2 57.5 55.2 53.8 57.0 56.2 51.9 48.3 46.9 49.7 53.7 56.9 54.4 52.0 50.3 45.2
50.4 50.2 49.2 50.0 52.5 53.3 51.0 51.2 52.0 54.1 50.5 50.1 49.2 49.9 52.4 53.3 50.9 51.0 51.6 53.6 49.8 49.3 46.6 44.1 42.2
49.6 50.2 50.2 50.1 49.2 51.8 55.0 55.4 54.5 49.3 49.7 50.3 50.4 50.0 49.1 51.7 54.7 55.1 54.1 48.9 49.2 49.6 46.4 44.3 40.7
49.7 46.5 46.3 48.4 49.9 49.5 56.7 57.6 52.1 50.1 49.8 46.6 46.5 48.4 49.8 49.4 56.5 57.2 51.8 49.5 49.2 45.8 42.2 42.6 41.2
48.1 45.7 48.9 45.1 50.2 50.1 53.4 54.1 50.1 50.2 48.2 45.9 48.9 45.0 50.3 49.8 53.1 53.8 49.8 49.8 47.6 44.7 44.3 39.2 41.4
47.9 45.7 48.8 45.0 50.2 49.9 53.1 54.0 50.1 50.2 47.9 45.7 48.9 45.0 50.0 49.7 53.0 53.7 49.7 49.8 47.4 44.7 44.4 39.2 41.4
49.4 46.1 46.0 48.1 49.6 49.2 56.4 57.3 51.8 49.9 49.5 46.2 46.1 48.0 49.5 49.1 56.1 57.2 51.5 49.4 48.9 45.4 41.9 42.5 40.9
49.3 49.7 49.8 49.6 48.9 51.4 54.5 54.9 53.9 48.7 49.4 50.0 49.8 49.6 48.8 51.3 54.3 54.7 53.8 48.3 48.8 49.2 46.3 44.0 40.4
49.7 49.4 48.5 49.1 51.8 52.7 50.4 50.6 51.4 53.4 49.8 49.4 48.5 49.2 51.9 52.5 50.2 50.4 51.2 53.0 49.3 48.9 45.9 43.7 41.7
56.6 54.4 52.9 56.3 55.6 51.2 47.7 46.6 49.3 53.4 56.7 54.4 53.0 56.1 55.4 51.0 47.5 46.2 49.1 52.9 56.1 53.6 51.5 49.8 44.7
56.3 54.2 52.8 56.0 55.2 51.0 47.5 46.1 49.2 53.0 56.6 54.1 52.6 56.0 55.3 50.9 47.4 46.0 49.0 52.8 56.0 53.5 51.4 49.7 44.6
49.1 48.9 47.9 48.7 51.2 52.0 49.9 50.1 50.6 52.7 49.2 49.0 47.9 48.6 51.3 51.8 49.5 49.6 50.4 52.5 48.6 48.3 45.5 43.4 41.5
48.1 48.7 48.7 48.6 47.7 50.3 53.5 53.9 52.9 47.8 48.3 48.8 48.8 48.6 47.5 50.1 53.3 53.7 52.5 47.6 47.8 48.2 45.4 43.2 39.6
47.9 44.6 44.5 46.6 48.0 47.7 54.7 55.8 50.1 48.1 47.9 44.7 44.6 46.5 47.9 47.5 54.5 55.6 49.9 47.8 47.6 44.2 40.7 41.2 39.9
45.4 42.7 45.8 42.2 47.7 47.8 51.1 52.0 48.0 48.0 45.4 42.8 45.7 42.1 47.7 47.8 50.9 51.8 47.8 47.7 45.1 41.9 41.6 36.8 39.5
41.8 39.5 42.6 38.9 44.1 44.6 49.3 50.8 45.5 44.5 42.0 39.6 42.7 38.8 44.2 44.4 49.1 50.6 45.3 44.3 41.7 38.7 38.5 33.5 36.1
42.3 38.9 38.7 40.9 42.6 42.3 47.8 48.0 44.3 42.9 42.3 38.9 38.8 40.9 42.3 42.0 47.7 47.9 44.0 42.3 41.9 38.3 34.8 35.7 34.6
39.9 40.7 43.1 43.6 42.6 39.3 40.3 40.6 40.5 40.6 39.6 40.4 43.1 43.5 42.5 38.7 39.9 39.9 37.1 35.3 32.4
37.9 38.4 37.0 37.3 37.5 38.8 36.7 36.6 35.4 36.6 37.6 38.4 36.8 37.1 37.3 38.4 36.2 35.9 33.0 31.5 30.9
29.7 32.0 33.5 35.5 34.9 33.5 35.8 34.5 32.5 30.6 29.4 31.6 33.2 34.9 34.1 32.1 31.1
24.7 25.4 27.9 29.3 27.6 27.4 28.4 28.9 26.4 24.7 24.4 25.0 27.3 28.7 26.6 26.2 25.1
20.9 21.6 22.3 20.5 20.5 21.0 20.2 21.5 21.7 21.0 20.8 20.9 21.5 20.1 19.8
22.2 23.1 23.5 23.9 25.6 25.6 23.9 23.8 22.9 22.2 22.3 23.2 23.7 24.3 26.0 26.0 24.4 23.8
27.4 27.3 27.4 28.4 29.9 30.0 28.8 27.8 27.3 27.5 27.5 27.2 27.6 28.9 30.3 30.3 29.1 27.7
32.7 32.1 30.6 30.2 30.5 30.6 30.6 30.7 31.9 32.5 32.5 31.8 30.8 31.1 31.2 31.2 31.1 30.9
37.6 35.3 32.7 33.7 33.5 33.5 33.8 32.4 34.4 36.8 36.8 34.5 33.0 35.0 34.8 34.8 35.1 33.1
24.2 24.2 23.7 24.8
28.9 30.1 30.5 29.9
33.0 33.8 34.6 33.4
34.8 37.4 37.8 35.5
29.9 31.4 32.4 31.7 30.9
32.9 33.2 35.7 35.2 32.4 15.1
50.9 50.6 50.8 50.4 49.1 21.2
51.1 50.4 22.2
24.6 24.6 24.9
25.9 25.6 25.7
29.0 28.9 29.3
31.9 31.2 31.4
54.9 51.2 46.6 45.8 49.2 53.7
54.3 50.6 48.3 47.2 49.5 52.8
48.2 52.3 51.0 51.6 51.9 50.5
47.6 48.3 54.9 55.0 51.8 47.5
47.9 47.9 53.7 54.4 48.8 48.3
46.1 46.0 49.9 51.1 46.2 46.3
43.2 43.5 49.1 49.7 44.4 43.6
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
B B
C C
D D
E E
(TYP.)
P1
(TYP.)
ZW2-T3
(TYP.)
W4
LIGHTING ILLUMINANCE (FC) SUMMARY
LEGEND OF REFLECTANCES
SURFACE REFLECTANCES ARE ASSUMED STANDARDS USED IN CALCULATION MODEL.
GENERAL
CEILING
WALLS
FLOOR
70%
50%
20%
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
LIGHTING SECOND
FLOOR
PHOTOMETRIC
E9.05
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING1/8" = 1'-0" 2 -FLOOR -LIGHTING SECOND FLOOR PHOTOMETRIC 1
N
Label
MEZZANINE
NOTE:
THIS LIGHTING CALCULATION REPRESENTS ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA TAKEN UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY (IES) APPROVED METHODS.
LLF Avg Max Min Max/Min Workplane Height
0.9 42.0 fc 57.6 fc 12.1 4.7:1 0 ft
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
EMEM
EM EM
EM
EM
EM
EM
EM EM
9.1 9.5 9.6 9.3 8.6 7.8 7.1 6.4 5.8 3.3 1.9 1.7 1.6 1.3 0.8 1.3 1.3 1.4 1.4 1.5 1.5 1.6 1.8 2.2 4.7 6.1 6.6 7.2 8.9 9.4 9.6 9.3 8.6 7.8 7.1 6.4 5.7 3.2 1.8 1.6 1.4 1.3 1.1
10.7 11.9 12.9 13.1 12.5 11.3 10.0 8.5 7.3 6.5 5.8 3.0 1.9 1.7 1.6 1.6 1.5 1.5 1.5 1.5 1.5 1.6 1.7 1.8 2.0 4.6 6.1 6.7 7.7 9.0 10.7 11.9 12.9 13.1 12.5 11.3 10.0 8.5 7.3 6.5 5.7 2.9 1.8 1.6 1.4 1.3
15.3 17.8 19.0 19.3 18.6 16.8 13.7 10.9 8.8 7.3 6.4 5.3 2.4 1.9 1.7 1.6 1.6 1.6 1.6 1.6 1.6 1.7 1.8 1.9 3.6 6.0 6.7 7.9 9.7 11.9 15.4 17.9 19.0 19.3 18.6 16.9 13.7 10.9 8.8 7.3 6.3 5.2 2.3 1.7 1.6 1.3
20.3 23.1 24.5 24.7 24.1 21.9 18.9 15.0 10.9 8.5 7.0 6.1 4.0 2.0 1.8 1.7 1.7 1.7 1.6 1.7 1.7 1.8 1.9 2.4 5.5 6.5 7.5 9.6 12.5 17.2 20.4 23.2 24.6 24.8 24.2 22.0 18.9 15.0 10.9 8.5 6.9 6.1 3.9 1.8 1.7 1.4
24.8 23.8 24.6 25.0 24.0 24.6 23.5 19.1 14.1 10.1 7.7 6.5 5.4 2.3 1.9 1.8 1.7 1.7 1.7 1.7 1.8 1.9 2.0 3.6 6.1 7.0 8.7 11.5 16.9 21.2 24.8 23.9 24.7 25.0 24.1 24.6 23.5 19.1 14.1 10.1 7.7 6.5 5.4 2.1 1.7 1.5
24.0 26.8 27.8 28.0 27.5 25.7 24.3 22.5 17.5 11.6 8.6 6.9 6.0 3.0 2.0 1.9 1.8 1.8 1.8 1.8 1.8 1.9 2.1 4.8 6.4 7.5 9.9 14.2 19.7 24.6 24.0 26.9 27.9 28.0 27.5 25.8 24.3 22.5 17.5 11.6 8.6 6.8 5.9 2.9 1.8 1.5
26.6 28.2 25.7 24.6 27.4 27.6 24.7 24.6 19.3 13.3 9.3 7.2 6.2 3.8 2.1 1.9 1.9 1.8 1.8 1.8 1.9 2.0 2.2 5.5 6.6 8.1 10.8 16.5 22.0 24.2 26.6 28.3 25.7 24.7 27.5 27.7 24.7 24.7 19.4 13.3 9.3 7.2 6.1 3.7 1.9 1.6
27.4 26.7 24.6 26.4 24.0 28.2 26.1 24.7 20.4 14.4 9.7 7.4 6.3 4.3 2.1 2.0 1.9 1.9 1.9 1.9 1.9 2.1 2.5 5.8 6.7 8.4 11.4 17.6 23.3 23.9 27.4 26.7 24.7 26.4 24.1 28.3 26.2 24.7 20.4 14.4 9.8 7.4 6.2 4.1 1.9 1.6
27.4 26.7 24.7 26.4 24.0 28.2 26.1 24.7 20.4 14.4 9.9 7.4 6.4 4.3 2.1 2.0 1.9 1.9 1.9 1.9 2.0 2.1 2.5 5.9 6.8 8.4 11.4 17.6 23.3 23.9 27.4 26.7 24.7 26.5 24.0 28.3 26.2 24.7 20.4 14.5 9.8 7.4 6.2 4.2 1.9 1.6
26.6 28.2 25.6 24.5 27.4 27.6 24.7 24.6 19.4 13.3 9.5 7.3 6.4 3.9 2.1 2.0 1.9 1.9 1.9 1.9 2.0 2.1 2.3 5.6 6.8 8.2 11.0 16.6 22.1 24.2 26.6 28.3 25.6 24.6 27.4 27.7 24.7 24.7 19.4 13.3 9.4 7.3 6.3 3.8 1.9 1.6
23.9 26.8 27.8 28.0 27.5 25.8 24.3 22.6 17.5 11.8 8.8 7.0 6.2 3.2 2.2 2.0 1.9 1.9 1.9 1.9 2.0 2.1 2.3 5.1 6.6 7.7 10.1 14.5 19.8 24.6 24.0 26.9 27.8 28.0 27.5 25.8 24.3 22.6 17.5 11.7 8.8 7.0 6.1 3.0 1.9 1.6
24.7 23.8 24.6 25.0 24.0 24.5 23.5 19.1 14.4 10.3 8.0 6.8 5.7 2.5 2.2 2.0 2.0 1.9 1.9 1.9 2.0 2.1 2.2 3.9 6.4 7.2 9.0 11.8 16.9 21.2 24.8 23.8 24.7 25.0 24.0 24.5 23.5 19.2 14.4 10.3 8.0 6.7 5.6 2.3 1.9 1.6
20.6 23.1 24.4 24.6 24.1 21.9 19.2 15.4 11.2 8.9 7.2 6.4 4.3 2.3 2.1 2.0 2.0 1.9 1.9 2.0 2.0 2.1 2.2 2.7 5.9 6.8 7.9 9.9 12.9 17.5 20.4 23.2 24.5 24.7 24.1 21.9 18.9 15.4 11.3 8.9 7.3 6.4 4.2 2.1 1.9 1.6
15.6 18.1 19.3 19.5 18.8 17.1 14.0 11.2 9.2 7.6 6.7 5.7 2.7 2.2 2.1 2.0 2.0 2.0 1.9 2.0 2.0 2.1 2.2 2.3 4.1 6.3 7.1 8.3 10.1 12.4 15.7 18.1 19.3 19.6 18.9 17.2 14.0 11.2 9.2 7.6 6.7 5.6 2.6 2.1 1.9 1.6
10.8 12.1 13.1 13.3 12.7 11.5 10.2 8.9 7.7 6.9 6.2 3.5 2.3 2.2 2.1 2.0 2.0 2.0 2.0 2.0 2.0 2.1 2.1 2.3 2.5 5.1 6.6 7.2 8.2 9.6 10.9 12.1 13.1 13.4 12.7 11.6 10.3 8.9 7.7 6.9 6.2 3.4 2.2 2.0 1.8 1.6
8.4 9.1 9.6 9.7 9.4 8.8 8.1 7.4 6.8 6.2 3.8 2.4 2.3 2.1 2.1 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.1 2.2 2.4 2.8 5.3 6.6 7.1 7.8 8.5 9.2 9.7 9.7 9.5 8.9 8.1 7.4 6.9 6.2 3.8 2.3 2.1 2.0 1.8 1.6
7.2 7.5 7.7 7.8 7.7 7.4 7.1 6.7 5.7 3.5 2.5 2.4 2.2 2.1 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.1 2.2 2.3 2.5 2.7 4.7 6.5 7.0 7.3 7.6 7.8 7.8 7.7 7.5 7.1 6.7 5.7 3.4 2.4 2.3 2.1 1.9 1.8 1.6
6.4 7.3 7.8 7.9 7.6 7.0 5.8 4.3 2.9 2.6 2.5 2.3 2.2 2.1 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.1 2.2 2.3 2.4 2.6 2.8 3.5 5.2 6.5 7.4 7.9 8.0 7.7 7.1 5.9 4.3 2.9 2.6 2.4 2.2 2.1 1.9 1.8 1.6
6.4 7.4 7.8 7.9 7.6 7.0 5.8 4.2 2.9 2.6 2.5 2.3 2.2 2.1 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.1 2.2 2.3 2.4 2.6 2.8 3.5 5.1 6.4 7.4 7.9 8.0 7.7 7.1 5.9 4.2 2.9 2.6 2.4 2.2 2.1 1.9 1.8 1.6
7.2 7.5 7.7 7.8 7.6 7.4 7.1 6.7 5.7 3.5 2.5 2.4 2.2 2.1 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.1 2.2 2.3 2.5 2.7 4.6 6.4 6.9 7.3 7.6 7.8 7.8 7.7 7.5 7.1 6.7 5.7 3.4 2.4 2.3 2.1 1.9 1.8 1.6
8.4 9.1 9.5 9.6 9.4 8.8 8.0 7.4 6.8 6.2 3.8 2.4 2.3 2.1 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.1 2.2 2.4 2.8 5.2 6.6 7.1 7.7 8.5 9.2 9.6 9.7 9.4 8.8 8.1 7.4 6.8 6.2 3.8 2.3 2.1 2.0 1.8 1.6
10.8 12.0 13.0 13.2 12.6 11.5 10.2 8.8 7.6 6.8 6.1 3.4 2.3 2.2 2.1 2.0 2.0 2.0 1.9 2.0 2.0 2.1 2.1 2.3 2.5 5.1 6.6 7.2 8.2 9.5 10.9 12.1 13.1 13.3 12.7 11.5 10.2 8.9 7.7 6.9 6.1 3.3 2.2 2.0 1.8 1.6
15.5 18.0 19.2 19.4 18.7 17.0 13.9 11.1 9.1 7.6 6.7 5.7 2.7 2.2 2.1 2.0 2.0 1.9 1.9 2.0 2.0 2.1 2.2 2.3 4.0 6.3 7.1 8.3 10.1 12.3 15.6 18.0 19.2 19.5 18.8 17.1 13.9 11.2 9.2 7.6 6.7 5.6 2.6 2.1 1.9 1.6
2.1 2.2 2.7 5.8 6.8 7.9 9.9 12.8 17.5 20.3 23.1 24.4 24.6 24.0 21.8 18.9 15.3 11.2 8.8 7.2 6.4 4.2 2.1 1.9 1.6
2.1 2.2 3.8 6.4 7.2 9.0 11.8 16.9 21.1 24.8 23.8 24.6 24.9 24.0 24.5 23.4 19.1 14.4 10.3 8.0 6.7 5.6 2.3 1.9 1.6
2.1 2.3 5.0 6.6 7.7 10.1 14.4 19.7 24.6 24.0 26.8 27.8 28.0 27.4 25.7 24.3 22.5 17.4 11.6 8.8 7.0 6.1 3.0 1.9 1.6
2.1 2.3 5.6 6.8 8.2 11.0 16.5 22.0 24.2 26.6 28.2 25.6 24.6 27.4 27.6 24.6 24.6 19.3 13.3 9.3 7.3 6.2 3.7 1.9 1.6
2.1 2.5 5.9 6.8 8.4 11.4 17.5 23.3 23.9 27.4 26.7 24.6 26.4 24.0 28.2 26.1 24.7 20.4 14.4 9.7 7.3 6.2 4.1 1.9 1.6
2.1 2.5 5.8 6.7 8.4 11.3 17.5 23.3 23.9 27.4 26.6 24.6 26.4 24.0 28.2 26.1 24.6 20.4 14.4 9.7 7.3 6.2 4.1 1.9 1.6
2.0 2.2 5.5 6.6 8.1 10.8 16.5 22.0 24.1 26.5 28.2 25.5 24.5 27.3 27.6 24.6 24.6 19.3 13.3 9.3 7.1 6.1 3.6 1.8 1.6
2.0 2.1 4.8 6.4 7.5 9.8 14.2 19.7 24.5 23.9 26.8 27.7 27.9 27.4 25.7 24.2 22.5 17.4 11.5 8.6 6.8 5.9 2.8 1.8 1.5
1.9 2.0 3.6 6.1 7.0 8.7 11.5 16.8 21.1 24.7 23.7 24.5 24.9 23.9 24.4 23.4 19.0 14.1 10.0 7.7 6.4 5.3 2.1 1.7 1.5
1.8 1.9 2.4 5.5 6.5 7.5 9.5 12.4 17.1 20.2 23.0 24.3 24.5 24.0 21.8 18.8 14.9 10.8 8.4 6.8 6.0 3.9 1.8 1.6 1.4
1.7 1.8 1.9 3.6 6.0 6.6 7.8 9.6 11.8 15.1 17.5 18.7 19.0 18.3 16.6 13.5 10.7 8.7 7.1 6.2 5.2 2.2 1.7 1.5 1.3
1.7 1.7 1.8 2.0 4.6 6.0 6.7 7.6 8.9 10.3 11.5 12.5 12.7 12.1 10.9 9.6 8.2 7.1 6.3 5.6 2.9 1.7 1.6 1.4 1.3
1.6 1.6 1.7 1.8 2.2 4.6 5.9 6.4 7.0 7.7 8.4 8.8 8.9 8.7 8.1 7.4 6.7 6.1 5.6 3.2 1.7 1.6 1.5 1.4 1.2
1.5 1.5 1.6 1.7 1.8 2.0 3.9 5.6 6.1 6.4 6.6 6.8 6.8 6.7 6.5 6.2 5.8 4.9 2.7 1.7 1.6 1.5 1.4 1.3 1.1
1.4 1.4 1.5 1.5 1.6 1.7 1.8 2.5 4.1 5.2 5.7 5.8 5.8 5.8 5.5 4.7 3.2 1.9 1.7 1.6 1.5 1.4 1.3 1.2 1.1
1.3 1.4 1.4 1.4 1.5 1.6 1.6 1.7 1.8 2.0 2.4 2.7 2.8 2.6 2.2 1.8 1.7 1.6 1.5 1.4 1.3 1.3 1.2 1.1 1.0
1.2 1.3 1.3 1.4 1.4 1.4 1.5 1.5 1.6 1.6 1.7 1.7 1.7 1.7 1.6 1.6 1.5 1.4 1.4 1.3 1.2 1.2 1.1 1.0 0.9
1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.2 1.3 1.3 1.3 1.4 1.4 1.4 1.5 1.5 1.5 1.5 1.5 1.4 1.4 1.4 1.3 1.3 1.2 1.2 1.1 1.0 1.0 0.9
1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.1 1.2 1.2 1.2 1.3 1.3 1.3 1.3 1.3 1.4 1.4 1.4 1.3 1.3 1.3 1.3 1.2 1.2 1.1 1.1 1.0 1.0 0.9 0.8
1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 1.2 1.2 1.2 1.2 1.3 1.3 1.3 1.3 1.2 1.2 1.2 1.2 1.1 1.1 1.0 1.0 0.9 0.9 0.8
1.0 0.9 0.9 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.1 1.1 1.1 1.2 1.2 1.2 1.2 1.1 1.1 1.1 1.1 1.0 1.0 1.0 0.9 0.9 0.8 0.8
0.9 0.8 0.8 0.8 0.8 0.8 0.9 0.9 0.9 0.9 1.0 1.0 1.0 1.0 1.0 1.1 1.0 1.0 1.1 1.0 1.0 1.0 1.0 1.0 0.9 0.9 0.8 0.8
7.6 6.5 5.5 4.8 4.4 3.5 1.9 1.6 1.5 1.5 1.5 1.6 1.6 1.9 3.5 4.4 4.8 5.4
9.4 7.5 6.2 5.2 4.7 4.2 2.7 1.7 1.6 1.6 1.6 1.6 1.7 2.6 4.2 4.7 5.2 6.2
11.9 9.0 7.1 5.8 5.0 4.5 3.6 1.9 1.7 1.7 1.7 1.7 1.9 3.6 4.5 5.0 5.8 7.0
13.5 11.0 8.0 6.4 5.3 4.7 4.2 2.3 1.8 1.7 1.7 1.8 2.3 4.2 4.7 5.3 6.4 7.9
5.0 3.7 1.8 1.7
5.4 4.8 2.7 1.8
5.8 5.1 4.0 1.9
6.3 5.4 4.8 2.5
3.1 1.6 1.5 1.0 0.9
3.6 2.0 1.6 1.1 1.0 0.9
3.9 2.4 1.7 1.2 1.1 0.9
1.3 1.1 1.0
12.5 12.9 13.1
12.5 12.5 12.6
13.2 13.7 13.9
14.0 14.3 14.5
1 1
2 2
3 3
4 4
5 5
6 6
7 7
8 8
9 9
A A
F F
B B
C C
D D
E E
(TYP.)
P1
(TYP.)
ZW2-T3
(TYP.)
W4
LIGHTING ILLUMINANCE (FC) SUMMARY
LEGEND OF REFLECTANCES
SURFACE REFLECTANCES ARE ASSUMED STANDARDS USED IN CALCULATION MODEL.
GENERAL
CEILING
WALLS
FLOOR
70%
50%
20%
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
LIGHTING SECOND
FLOOR
EMERGENCY
PHOTOMETRIC
E9.06
08/01/2025
ABSPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING1/8" = 1'-0" LIGHTING SECOND FLOOR EMERGENCY PHOTOMETRIC 1
N
Label LLF Avg Max Min Max/Min
MEZZANINE 0.9 8.1 fc 28.3 fc 0.8 fc 35.3:1
NOTE:
THIS LIGHTING CALCULATION REPRESENTS ILLUMINATION LEVELS CALCULATED FROM LABORATORY DATA TAKEN UNDER CONTROLLED CONDITIONS IN ACCORDANCE WITH ILLUMINATING ENGINEERING SOCIETY (IES) APPROVED METHODS.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
T FOR REGULATORY APPROVAL,
ERMITTING OR CONSTRUCTION
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIO
OT FOR REGULATORY APPROV
PERMITTING OR CONSTRUCTIOREE22215R
*ST
A
T
EEGISTE
OF CA L I F
N IO R R*ANGINEER
ED P SOFES ION
A
L
ALDO G E R A R DO B
A
CUZZIELECT R I C A L
3/31/26
FIRE ALARM PLAN REQUIREMENTS
1. ALL WALL-MOUNTED VISUAL SIGNALING APPLIANCES AND COMBINATION AUDIBLE/VISUAL SIGNALING APPLIANCES SHALL BE MOUNTED SUCH THAT THE ENTIRE LENS IS NOT LESS THEN 80 INCHES AND NO GREATER THEN 96 INCHES ABOVE THE FINISHED FLOOR. ALL WALL MOUNTED AUDIBLE SIGNALING APPLIANCES SHALL HAVE THEIR TOPS ABOVE FINISHED FLOOR AT HEIGHTS NOT LESS THEN 90 INCHES AND BELOW FINISHED CEILING ON NOT LESS THEN 6 INCHES (WHICHEVER IS LOWER).
2. ALL EQUIPMENT SHALL BE U.L. AND C.S.F.M. LISTED.
3. ALL WIRING SHALL BE IN ACCORDANCE WITH THE C.E.C. AND AUTHORITIES HAVING JURISDICTION.
4. ALL JUNCTION BOXES SHALL BE SIZED IN ACCORDANCE WITH THE C.E.C. AND SHALL HAVE THEIR COVERS PAINTED RED WHERE APPLICABLE.
5. ELECTRICAL CONTRACTOR SHALL FURNISH ACCESS PANELS TO AREAS THAT REQUIRE SERVICING, TROUBLE SHOOTING, ETC.
6. DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM ELECTRICAL ENGINEER. FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC., THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR.
7. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR-FLOW, NOR CLOSER THEN 3 FEET (915mm) FROM AN AIR SUPPLY DIFFUSER.
8. ALL FAN SHUTDOWN FUNCTIONS, DAMPER CLOSURES AND ASSOCIATED MECHANICAL SYSTEM FIRE ALARM INTERFACE SHALL BE BY MECHANICAL CONTRACTOR, AND SHALL BE COORDINATED WITH FIRE ALARM SYSTEM.
9. ALL DUCT SMOKE DETECTORS SHALL BE MOUNTED BY THE MECHANICAL CONTRACTOR. DUCT SMOKE DETECTORS EXPOSED TO THE WEATHER SHALL BE C.S.F.M. LISTED FOR OUTDOOR INSTALLATION, AND WEATHER PROTECTED BY THE MECHANICAL CONTRACTOR. ALL AIR VELOCITY TESTING SHALL BE PERFORMED BY THE MECHANICAL CONTRACTOR.
10. ALL 120VAC POWER REQUIREMENTS FOR THE FIRE ALARM SYSTEM SHALL BE FURNISHED BY THE ELECTRICAL CONTRACTOR AND SHALL MEET ALL REQUIREMENTS OF THE AUTHORITIES HAVING JURISDICTION.
11. ALL FIRE ALARM DEVICE BACKBOXES, FIRE ALARM TERMINAL CABINETS, GUTTERS, JUNCTION BOXES, AND ASSOCIATED CONDUITS SHALL BE FURNISHED AND INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. REFER TO FIRE ALARM SYMBOL LIST AND/OR MOUNTING DETAILS FOR ADDITIONAL INFORMATION. SYSTEM SUPPLIER PROVIDED BACKBOXES SHALL BE INSTALLED BY ELECTRICAL CONTRACTOR UNLESS OTHERWISE NOTED. FIRE ALARM PANEL, REMOTES AND COMPONENTS SHALL BE SECURED TO MOUNTING SURFACES PER MANUFACTURER'S SPECIFICATIONS. NO SINGLE DEVICE SHALL EXCEED THE WEIGHT OF 20 LBS. WITHOUT SPECIAL MOUNTING DETAILS.
12. SMOKE DETECTOR TESTING SHALL BE CONDUCTED IN ACCORDANCE WITH NFPA 72, ALL APPLICABLE CODES AND THE MANUFACTURER'S INSTRUCTIONS.
13. ALL WIRING, INITIATING DEVICES AND ANNUNCIATOR PANEL SHALL BE SUPERVISED TO THE PRINCIPAL POINT OF ANNUNCIATION. THE FIRE ALARM CONTROL PANEL TO SUPERVISE THE ANNUNCIATOR PANEL, ALL INITIATING AND INDICATING DEVICE CIRCUITS.
14. ALL WIRING SHALL BE CUT FOR IN AND OUT. WIRING SHALL NOT BE LOOPED THROUGH DEVICES PER CEC STANDARDS, ALL WIRING IS TO BE PULLED THROUGH EACH JUNCTION BOX AND CONNECTED DIRECTLY TO EACH FIRE DEVICE. DO NOT SPLICE THE WIRE. THERE MUST BE AT LEAST 6' OF LEAD WIRE FROM THE BOX TO THE DEVICE.
15. POINT AND COMMON ANNUNCIATION IS PROHIBITED. SLC MAY BE T-TAPED ONLY AT BUILDING FATC IF NECESSARY. INSTALL SLC LOOPED WITHIN ALL BUILDINGS AS SHOWN ON THE FLOOR PLANS.
16. PROVIDE 3/4" CONDUIT FROM FIRE ALARM CONTROL PANEL TO TELEPHONE BACKBOARD FOR OWNER PROVIDED CENTRAL STATION MONITORING.
17. CONTRACTOR TO FIELD VERIFY AND PROVIDE DECIBEL METER FOR TESTING OF AMBIENT NOISE LEVELS (MINIMUM 15db ABOVE AVERAGE AMBIENT NOISE LEVEL BUT NOT LESS 75 DBA AT 10 FEET OR MORE THAN 110 DBA AT THE MINIMUM HEARING DISTANCE -SEE NFPA 72 APPENDIX A.7.4.2.1.) INSTALL ADDITIONAL AUDIBLE DEVICES AS NEEDED TO ATTAIN REQUIRED NOISE LEVELS IN ALL REQUIRED AREAS. PROVIDE UPDATED PLANS AND CALCULATIONS THROUGH THE "CHANGE ORDER" PROCESS WHEN INSTALLING ADDITIONAL DEVICES. INSPECTOR OF RECORD (IOR) TO WITNESS FINAL TEST OF SYSTEM. CONTRACTOR(S) TO PROVIDE FINAL TEST RESULT AND "RECORD OF COMPLETION" TO ARCHITECT OF RECORD, OWNER, DIVISION OF THE STATE ARCHITECT, IOR AND LOCAL FIRE AUTHORITY.
18. ALL CONDUITS ARE 3/4" U.O.N. ALL FIRE ALARM CIRCUITS SHALL BE IN CONDUIT, SURFACE RACEWAY OR OPEN RUN ABOVE CEILINGS, UNDER FLOORS AND IN WALLS IN A NEAT AND PROTECTED MANOR AS INDICATED ON DESIGN DOCUMENTS.
EXPOSED CIRCUITS ARE ONLY PERMITTED WHEN NOTED AS EXPOSED ON DESIGN DOCUMENTS.
19. ALL FLOW SWITCHES SHALL BE 2 WIRE WITH NON-ELECTRONIC RETARD TYPE SIMILAR TO THE SYSTEM SENSOR MODEL "WFD SERIES" ONLY.
20. ALL DEVICES IN THE ALARM SYSTEM SHALL BE COMPATIBLE AND INSTALLED PER MANUFACTURER'S SPECIFICATIONS.
21. SYSTEM SHALL BE FURNISHED AND INSTALLED BY A MANUFACTURER'S AFFILIATE AND AUTHORIZED DISTRIBUTOR. FIRE ALARM SYSTEM INSTALLATION COMPANY SHALL BE UL LISTED (UUJS). INSTALLING CONTRACTOR SHALL PROVIDE SYSTEM PROGRAMMING FOR SUPERVISORY MONITORING PER CBC SECTION 901.6.2. SUPERVISORY MONITORING SHALL BE TESTED AND VERIFIED AS SENDING CORRECT SIGNALS IN CONJUNCTION WITH FINAL ACCEPTANCE TEST. OWNER SHALL BE RESPONSIBLE FOR ESTABLISHING A FIRE SYSTEM MONITORING CONTRACT OR PROVISIONS.
22. DETECTORS SHALL NOT BE INSTALLED UNTIL AFTER THE CONSTRUCTION CLEAN-UP OF ALL TRADES IS COMPETE AND FINAL. DETECTORS THAT HAVE BEEN INSTALLED PRIOR TO FINAL CLEAN-UP BY ALL TRADES SHALL BE CLEANED OR REPLACED IN ACCORDANCE WITH CHAPTER 7. CLEANING OR REPLACEMENT OF DEVICES THAT WERE MOUNTED AT THE
REQUEST OF THE CONTRACTOR WILL NOT BE PERFORMED WITHOUT WRITTEN AUTHORIZATION THAT ASSUMES FINANCIAL RESPONSIBILITY FOR COSTS INCURRED. SEE THE LATEST VERSION OF NFPA 72.
23. PER ADAAG, 2013 -4.27.4, CONTROLS AND OPERATING MECHANISMS AT INITIATING DEVICE CONTROLS AND OPERATING MECHANISM AT INITIATING DEVICE "SHALL BE OPERABLE WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, PINCHING, OR TWISTING OF THE WRIST. THE FORCE REQUIRED TO ACTIVATE CONTROLS SHALL BE NO GREATER THAN 5lbf (22.2N)."
24. FIRE ALARM SYSTEM CONTROL PANEL SHALL HAVE PROGRAMMING TO ALLOW FOR THE MANUAL SILENCING OF THE AUDIBLE PORTION OF AN ALARM WHILE MAINTAINING THE ALARM STATUS OF ALL VISUAL DEVICES WITHIN THE SYSTEM.
25. THE SYSTEM SHALL CONFORM TO CALIFORNIA CODE OF REGULATIONS (CCR) TITLES 19 AND 24 AS APPLICABLE TO THIS PROJECT.
26. SPEAKER COVERAGE SHALL COMPLY WITH NFPA 72 AND 2013 CBC. PROVIDE 2W SPEAKER COVERAGE IN CLASSROOMS AND 1/4W IN SMALL SPACES (OFFICES, RESTROOMS AND STORAGE/SUPPORT).
27. ALL FIRE ALARM SYSTEM VISUAL SIGNAL BE SYNCHRONIZED THROUGHOUT THE SITE.
28. WHERE SPEAKER/STROBE OCCUR AT WHITEBOARDS, LOCATE DEVICE(S) +4" ABOVE TOP OF WHITEBOARD, NOT TO EXCEED 96" TO TOP OF LENS.
29. PROVIDE A LABEL WITHIN THE FACP AND EACH POWER SUPPLY WITH THE PANEL NUMBER AND CIRCUIT NUMBER OF THE 120 VOLT POWER SOURCE.
30. WHERE A DETECTOR IS INSTALLED ABOVE THE CEILING, THE DETECTOR SHALL BE EASILY ACCESSIBLE AND THE LOCATION OF THE DETECTOR SHALL BE CLEARLY MARKED. FOR DUCT SMOKE DETECTORS A REMOTE TEST STATION SHALL BE PROVIDED.
31. TEMPERATURE SETTINGS OF HEAT DETECTOR DEVICES ARE TO BE SET AT A MINIMUM OF 20°F. ABOVE THE MAXIMUM EXPECTED TEMPERATURE OF THE SPACE INSTALLED PER NFPA 72, 2-23.
32. MECHANICAL UNIT (HVAC) SHUT DOWN SHALL UTILIZE FULLY AUTOMATIC FIRE ALARM SYSTEM AREA SMOKE COVERAGE TO TRIGGER RELAY FOR HVAC UNIT SHUT DOWN (PER CMC 608).
33. UPON COMPLETION OF SYSTEM INSTALLATION, THE SYSTEM SHALL BE TESTED IN THE PRESENCE OF AND IN A MANNER ACCEPTABLE TO DSA/I.O.R. CONTRACTOR SHALL SUPPLY NECESSARY TESTING EQUIPMENT, INCLUDING A "SOUND LEVEL METER" TO CHECK ACCEPTABLE NOISE LEVELS OF AUDIBLE DEVICES. PROVIDE TEST RESULTS PER NFPA 72 TO ARCHITECT, D.S.A., I.O.R. AND TO LOCAL FIRE AUTHORITY. THE INSTALLING CONTRACTOR SHALL PROVIDE A RECORD OF COMPLETION PER NFPA72, FIGURE 10.18.2.1.1.
34. THE "END OF LINE RESISTANCE" OF EACH CIRCUIT SHALL BE TESTED IN THE PRESENCE OF THE I.O.R. AND SHALL NOT EXCEED A MAXIMUM OF 10% VOLTAGE DROP, OR LISTED MANUFACTURER'S MINIMUM OPERATING VOLTAGE.
35. REFER TO DETAIL SHEET FOR EXTERIOR HORN MOUNTING.
36. ALL WIRING USED IN UNDERGROUND CONDUIT SHALL BE LISTED FOR WET AREA APPLICATION, IN ACCORDANCE WITH CEC 760.
37. ALL UNDERGROUND FIRE ALARM SYSTEM CONDUCTORS SHALL BE CONTINUOUS FROM END TO END. NO UNDERGROUND SPLICES WILL BE PERMITTED, NOR ACCEPTABLE.
38. FIRE ALARM SYSTEM IS FULLY AUTOMATIC SYSTEM.
39. APPLICABLE STANDARD 2013 NFPA 72.
40. INSTALLATION OF THE SYSTEM SHALL NOT BE STARTED UNTIL DETAILED DESIGN DOCUMENTS AND SPECIFICATION, INCLUDING STATE FIRE MARSHAL LISTING NUMBERS FOR EACH COMPONENT OF THE SYSTEM HAS BEEN APPROVED BY DSA.
41. A STAMPED SET OF APPROVED FIRE ALARM DESIGN DOCUMENTS SHALL BE ON THE JOB SITE AND USED FOR INSTALLATION.
42. ANY DISCREPANCIES BETWEEN THE DRAWINGS AND THE CODE OR RECOGNIZED STANDARDS SHALL BE BROUGHT TO THE ATTENTION OF DSA AND THE ARCHITECT/ENGINEER OF THE PROJECT.
43. DSA, ARCHITECT/ENGINEER AND OWNER SHALL BE NOTIFIED A MINIMUM OF 48 HOURS PRIOR TO THE FINAL INSPECTION AND/OR TESTING.
44. ALL PENETRATIONS THROUGH RATED ASSEMBLIES, REQUIRING OPENING PROTECTION SHALL BE PROVIDED WITH A PENETRATION FIRE STOP SYSTEM AS IDENTIFIED IN CBC CHAPTER 7, UL OR OTHER LAB TESTING CRITERIA. APPROVED TYPE OF MATERIALS SHALL BE IDENTIFIED WITHIN THE SPECIFICATION WITHIN THE FIRE ALARM SECTION.
45. PROVIDE COMPLETE VOICE EVACUATION SYSTEM. PROVIDE ALL COMPONENTS, DEVICES AND PANELS FOR A COMPLETE SYSTEM.
46. THE CONTRACTOR SHALL ADJUST/INSTALL ALL DEVICES TO MAXIMIZE PERFORMANCE AND TO MINIMIZE FALSE ALARMS.
47. VISUAL DEVICES SHOULD NOT EXCEED 2 FLASHES PER SECOND AND SHOULD NOT BE SLOWER THAN 1 FLASH EVERY SECOND. THE DEVICE SHALL HAVE A PULSING LIGHT SOURCE NOT LESS THAN 15 CANDELLA. VISUAL DEVICES WITHIN 55' FROM EACH OTHER SHALL BE SYNCHRONIZED.
48. UNDERGROUND AND EXTERIOR CONDUITS TO HAVE WATERTIGHT FITTINGS AND WIRE TO BE APPROVED FOR WET LOCATIONS.
49. ALL FIRE ALARM WIRING SHALL BE FLP OR FPLP (FIRE POWER LIMITED OR FIRE POWER LIMITED PLENUM) AS REQUIRED FOR APPLICATION. WIRING IN CONDUIT ABOVE GROUND MAY BE THHN OR THWN.
50. ALL LED REMOTE INDICATORS FOR DUCT DETECTORS AND FIRE/SMOKE DAMPERS REQUIRED BY THE LOCAL AHJ SHALL BE LOCATED IN CEILINGS IN COORDINATION WITH ARCHITECT PRIOR TO ANY ROUGH-IN.
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
FIRE ALARM LEAD
SHEET
FA0.01
08/01/2025
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGFIRE ALARM SEQUENCE OF OPERATIONS
SHUT DOWN
AH-UNIT
CONTROL PANEL
CLOSE CSFD
ACTIVATE
ELEVATOR
RECALL
MONITOR TO
UL LISTED
CENTRAL
STATION
ACTIVATE
TROUBLE OR
SUPERVISORY
SIGNAL
ACTIVATE
REMOTE
ANNUNCIATOR
ACTIVATE
ALL SIGNALS
ACTION
DEVICE
ACTIVATE
ELEVATOR
SHUNT TRIP
MANUAL PULL STATION
SMOKE DETECTOR
HEAT DETECTOR
A/C POWER FAILURE
WIRING FAULTS
ELEVATOR ROOM SMOKE
ELEVATOR ROOM HEAT
WATERFLOW
TAMPER
YES
YES
YES
YES
NO
NO
YES
YES
YES
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
YES
YES
NO
NO
NO
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
YES
NO
NO
NO
NO
NO
YES
NO
NO
YES
NO
NO
NO
NO
NO
NO
YES
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
NO
NO
YES
NO
YES
YES
NO
NO
YES
YES
YES
NO
NO
CONDUCTOR
DESIGNATION WIRE IN CONDUIT
WIRE IN CONDUIT
UNDERGROUND / WET
LOCATION CIRCUIT TYPE
2 #16 UNSHIELDED (WEST PENN #D990)2 #16 FPL UNSHIELDED (WEST PENN #AQ-225)INITIATING CIRCUIT NOTE:
1. ALL WIRE MODEL NUMBERS ARE WEST PENN. EQUIVALENT BY OTHER MANUFACTURER IS ACCEPTABLE.
2. COLOR CODE ALL FIRE ALARM CONDUCTORS PER CITY STANDARDS. VERIFY COLOR SCHEMES PRIOR TO ORDERING FIRE ALARM CONDUCTORS.
3. ALL WIRE SHALL BE IN 3/4" CONDUIT, U.O.N.
CONDUCTOR
DESIGNATION
ZUZ
2 #12 THHN STRANDED 2 #12 THWN STRANDED A/V CIRCUITNUN
2 #12 THHN STRANDED 2 #12 THWN STRANDED POWER CIRCUITPUP 2 #12 THHN STRANDED 2 #12 THWN STRANDED NETWORK CONTROLCUC NUMBER OF CONDUCTOR PAIRSEXAMPLE:
CONDUCTOR DESIGNATION
2N
ABOVE EXAMPLE "2N" MEANS "2 PAIRS OF #12 WIRE"
2 #12 THHN STRANDED 2 #12 THWN STRANDED SPEAKER CIRCUITSUS
WIRE LEGEND
AUTOMATIC FIRE ALARM SYSTEM
COMPLETE FIRE ALARM
SUBMITTAL
TO PROVIDE AND INSTALL A NEW ANALOG
ADDRESSABLE, VOICE EVAC, AUTOMATIC,
POWER LIMITED 24V DC SUPERVISED FIRE
ALARM SYSTEM WITHIN THE
MAIN AND STEM BUILDINGS
AS INDICATED ON PLANS.
FIRE ALARM SCOPE OF WORK
B
T
W
WP
SYMBOL LEGEND
SYMBOL MODEL MFGR DESCRIPTION
6820EVS FIRE ALARM CONTROL PANEL
W/EMERGENCY VOICE SYSTEM 7165-0559:0500
C.S.F.M. #
FAPS
FACP
6860 REMOTE ANNUNCIATOR PANEL 7165-0559:0500
SILENT KNIGHT
SILENT KNIGHT
SK-PHOTO ADDRESSABLE SMOKE DETECTOR 7272-0559:0512
B300-6 DETECTOR BASE 7300-1653:0238SYSTEM SENSOR
SILENT KNIGHT
ANN
SK-MONITOR ADDRESSABLE MONITOR MODULE 7300-0559:0155
SK-HEAT ADDRESSABLE HEAT DETECTOR 7270-0559:0511
B300-6 DETECTOR BASE 7300-1653:0238
Zc
SPSCWL CEILING SPEAKER/STROBE
SPSWL WALL SPEAKER/STROBE
SPWK WALL SPEAKER (EXTERIOR)
7320-1653:0505
7320-1653:0505
7320-1653:0201
Zm
SYSTEM SENSOR
SYSTEM SENSOR
SYSTEM SENSOR
SYSTEM SENSOR
SILENT KNIGHT
SILENT KNIGHT
--WATERFLOW (BY FIRE SPRINKLER CONSULTANT)---
SK-MINIMON MINI MONITOR MODULE 7300-0028:219
--TAMPER SWITCH (BY FIRE SPRINKLER CONSULTANT)---
SK-MINIMON MINI MONITOR MODULE 7300-0559:0155
SK-PULL-SA ADDRESSABLE PULL STATION-SINGLE ACTION 7150-0559:0161 --120VAC BELL (BY FIRE SPRINKLER CONSULTANT)-----
F
--
--
SILENT KNIGHT
SILENT KNIGHT
SILENT KNIGHT
SK-CONTROL ADDRESSABLE RELAY MODULE 7300-0559:0155SILENT KNIGHT SK-PS6 FIRE ALARM POWER SUPPLY PANEL 7315-0559:0522SILENT KNIGHT SK-DUCT ADDRESSABLE AIR DUCT SMOKE DETECTOR 3242-0559:0162 RTS151 MAGNETIC REMOTE TEST STATION 7300-1653:0212SYSTEM SENSOR
SILENT KNIGHT
B
WP
WPWPWPWPF Zc
Zc
Zc
Zm
F
FWPWPFFF
WP
F
Zc
Zc
Zc
Zc
T
W
CMMWREF.TVTVPRINT
B
WP
WPWPF Zc
Zc
Zc
Zm
F
FFFF
FF
FF
T
W
1 2 3
5 6 7 8 9
A
F
11 10
12 G G
B
C
D
E
STEM
CLASSROOM
113
STAFF
ROOM
102
MEN'S
RESTROOM
106
MECHANICAL
ROOM
103
ELECTRICAL
ROOM
104
IDF
ROOM
105
FAMILY
RESTROOM
108
NURSING
ROOM
116
WOMEN'S
RESTROOM
107
EXHIBIT
SPACE
100
STORAGE
101
ELEVATOR
111
ELEVATOR
MACHINE
ROOM
110
STORAGE
101
EXHIBIT
SPACE
100
FAPS FACP
15cd
30cd
30cd
30cd
75cd
75cd
15cd
110cd
110cd110cd
110cd
110cd
110cd
110cd110cd
STAFF
RESTROOM
11415cd
ELECTRICAL
ROOM
104
10' - 0"
GYP-2
10' - 0"
GYP-2
10' - 0"
CL-1
10' - 0"
GYP-210' - 0"
GYP-2
EXP
EXP
EXP
EXP
EXP
EXP
11' - 0"
CL-1
11' - 0"
CL-1
STEM
CLASSROOM
112
EXP
TYP.
FA-1009
FA-1004
FA-1006
STAIR
STAIR
110cd
110cd
ANNUNCIATOR PANEL
HOME RUN TO FACP IN
ELECT. ROOM 104
AHU-2
AHU-1
FC-1
FC-2
FA-1008
FA-1008
FA-1005
TYP.
FA-1009
TYP.
FA-1009
KEYNOTES
1. X
LEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
CL-1
2 X 4 SUSPENDED ACOUSTICAL CEILING TILE,
ARMSTRONG, CALLA, VECTOR
MTL-1
LINEAR METAL CEILING PANEL [MANUFACTURER,
PRODUCT LINE, SIZE, COLOR: TBD, TO MATCH
INSULATED METAL PANEL INSIDE FACE] (EXTERIOR)
GYP-1
FRAMED GYPSUM BOARD CEILING
GYP-2
FRAMED GYPSUM BOARD, MOISTURE RESISTANT,
SEMI-GLOSS PAINT (WET LOCATIONS)
OPEN TO STRUCTURE ABOVE
ALL EXPOSED SURFACES PAINTED P-1
TEC-1
TECTUM CEILING PANELS ATTACHED TO ROOF
PURLINS
EXHIBIT
SPACE
100
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
FIRST FLOOR FIRE
ALARM RCP
FA2.01
08/01/2025
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
1. 2.
DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER/ENGINEER.
FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC. THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
3. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR-FLOW , NOT CLOSER THAN 3 FEET FROM ANY SUPPLY DIFFUSER.
4. FIRE ALARM EVACUATION SIGNAL SHALL BE CLEARLY HEARD AND COMPLY WITH 2016 NFPA 72 18.4.3.1.
5. REFER TO ARCHITECTURAL EXTERIOR ELEVATIONS FOR PRECISE OUTLET LOCATIONS.
6. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL CEILING MOUNTED DEVICES.
7. IF SHIELDED WIRE IS USED, THE FOLLOWING MUST BE OBSERVED.
A. METALLIC CONTINUITY OF THE SHIELD MUST BE MAINTAINED AND INSULATED THROUGHOUT THE ENTIRE LENGTH OF THE CABLE.
B. THE ENTIRE LENGTH OF THE CABLE MUST HAVE A RESISTANCE GREATER THAN 1 MEGAOHM TO EARTH.
8. ALL PENETRATIONS THROUGH FIRE RATED WALL SHALL BE PROTECTED
FROM THE SPREAD OF FIRE WITH AN APPROVED FIRE STOP SYSTEM
EQUAL TO OR GREATER THAN THE FIRE RATING OF THE STRUCTURE / SURFACE BEING PENETRATED.
9. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND LIGHTING PROTECTION DEVICES. THIS CONNECTION SHALL BE MADE TO AN APPROVED DEDICATED EARTH CONNECTION PER CEC, ARTICLE 250.
10. WIRING IN DUCTS, PLENUMS AND OTHER AIR HANDLING SPACES MUST BE INSTALLED IN ACCORDANCE WITH CEC 2019.
11. UNDERGROUND WIRING MUST BE FREE OF ALL WATER.
ALL FIRE ALARM SYSTEM CONDUCTORS SHALL BE RUN IN A DEDICATED FIRE ALARM CONDUIT SYSTEM.
ITEM DESCRIPTION
FA-1004 PROVIDE AND CONNECT FIRE ALARM RELAY/MONITOR MODULES TO
ELEVATOR CONTROL SYSTEM FOR PRIMARY & ALTERNATE RECALL, ELEVATOR POWER SHUNT-TRIP, AND MONITOR SHUNT-TRIP POWER.
FA-1005 SPRINKLER BELL PROVIDED BY FIRE PROTECTION CONTRACTOR. PROVIDE 120VAC TO ENERGIZE SPRINKLER BELL. CONNECT BELL DIRECTLY TO WATER FLOW SWITCH.
FA-1006 INSTALL HEAT DETECTOR(S) WITHIN 24” OF EACH SPRINKLER HEAD OF ELEVATOR SHAFT/PIT AND ELEVATOR MACHINE ROOM.
FA-1008 PROVIDE FIRE ALARM RELAY MODULE WITH INTERPOSING RELAY FOR
MECHANICAL EQUIPMENT AUTO SHUTDOWN (HVAC UNITS, FIRE SMOKE
DAMPERS, HIGH VOLUME LOW SPEED FANS) VERIFY EXACT LOCATION AND QUANTITY ON MECHANICAL DRAWINGS.
FA-1009 INSTALL EXTERIOR SPEAKERS PER MANUFACTURER'S INSTALLATION
INSTRUCTIONS, REFER TO THE PROPER DEVICE INSTALLATION
INSTRUCTIONS FOR WEATHERPROOF BACKBOX REQUIREMENT.
Zc
Zc
F
1 2 3 4 5 6 7 8 9
A
10 B
C
D
E
ELEVATOR
111
OPEN
EXHIBIT
SPACE
200
75cd
75cd
75cd75cd75cd
15cd15cd
75cd
47' - 3"
TEC-1
47' - 3"
TEC-1
47' - 3"
TEC-1
47' - 3"
TEC-1
47' - 3"
TEC-1
47' - 3"
TEC-1
47' - 3"
TEC-1
47' - 3"
TEC-1
STAIR
STAIR
FA-1008
FA-1008
FA-1012
KEYNOTES
1. X
LEGENDGENERAL NOTES
METAL STUD WALL CONSTRUCTION
1 HOUR RATED METAL STUD WALL CONSTRUCTION
2 HOUR RATED METAL STUD WALL CONSTRUCTION
CL-1
2 X 4 SUSPENDED ACOUSTICAL CEILING TILE,
ARMSTRONG, CALLA, VECTOR
MTL-1
LINEAR METAL CEILING PANEL [MANUFACTURER,
PRODUCT LINE, SIZE, COLOR: TBD, TO MATCH
INSULATED METAL PANEL INSIDE FACE] (EXTERIOR)
GYP-1
FRAMED GYPSUM BOARD CEILING
GYP-2
FRAMED GYPSUM BOARD, MOISTURE RESISTANT,
SEMI-GLOSS PAINT (WET LOCATIONS)
OPEN TO STRUCTURE ABOVE
ALL EXPOSED SURFACES PAINTED P-1
TEC-1
TECTUM CEILING PANELS ATTACHED TO ROOF
PURLINS
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/20251/8" = 1'-0"COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
MEZZANINE FIRE
ALARM RCP
FA2.02
08/01/2025
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN
1. 2.
DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER/ENGINEER.
FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC. THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
3. DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR-FLOW , NOT CLOSER THAN 3 FEET FROM ANY SUPPLY DIFFUSER.
4. FIRE ALARM EVACUATION SIGNAL SHALL BE CLEARLY HEARD AND COMPLY WITH 2016 NFPA 72 18.4.3.1.
5. REFER TO ARCHITECTURAL EXTERIOR ELEVATIONS FOR PRECISE OUTLET LOCATIONS.
6. REFER TO ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF ALL CEILING MOUNTED DEVICES.
7. IF SHIELDED WIRE IS USED, THE FOLLOWING MUST BE OBSERVED.
A. METALLIC CONTINUITY OF THE SHIELD MUST BE MAINTAINED AND INSULATED THROUGHOUT THE ENTIRE LENGTH OF THE CABLE.
B. THE ENTIRE LENGTH OF THE CABLE MUST HAVE A RESISTANCE GREATER THAN 1 MEGAOHM TO EARTH.
8. ALL PENETRATIONS THROUGH FIRE RATED WALL SHALL BE PROTECTED
FROM THE SPREAD OF FIRE WITH AN APPROVED FIRE STOP SYSTEM
EQUAL TO OR GREATER THAN THE FIRE RATING OF THE STRUCTURE / SURFACE BEING PENETRATED.
9. A SYSTEM GROUND MUST BE PROVIDED FOR EARTH DETECTION AND LIGHTING PROTECTION DEVICES. THIS CONNECTION SHALL BE MADE TO AN APPROVED DEDICATED EARTH CONNECTION PER CEC, ARTICLE 250.
10. WIRING IN DUCTS, PLENUMS AND OTHER AIR HANDLING SPACES MUST BE INSTALLED IN ACCORDANCE WITH CEC 2019.
11. UNDERGROUND WIRING MUST BE FREE OF ALL WATER.
ALL FIRE ALARM SYSTEM CONDUCTORS SHALL BE RUN IN A DEDICATED FIRE ALARM CONDUIT SYSTEM.
ITEM DESCRIPTION
FA-1008 PROVIDE FIRE ALARM RELAY MODULE WITH INTERPOSING RELAY FOR MECHANICAL
EQUIPMENT AUTO SHUTDOWN (HVAC UNITS, FIRE SMOKE DAMPERS, HIGH VOLUME LOW SPEED FANS) VERIFY EXACT LOCATION AND QUANTITY ON MECHANICAL DRAWINGS.
FA-1012 IN AN ELEVATOR LOBBY WITH A HIGH CEILING, SMOKE DETECTOR IS TO PROTECT THE ELEVATOR LOBBY, SMOKE DETECTOR WILL BE MOUNTED ON THE WALL WITHIN 60 INCHES OF THE TOP OF THE ELEVATOR DOOR.
SIMPLEX
SIMPLEX
PULL DOWN
HEAT
DETECTOR
ROOF/FLOOR DECK
18" BEAM OR
SMALLER
ACCESSIBLE CEILING OR CEILING ACCESS PANEL
ROOF/FLOOR DECK
ACCESSIBLE CEILING OR CEILING ACCESS PANEL
DETECTOR
COVERAGE
HEAT
DETECTOR
19" BEAM OR
LARGERDETECTOR
COVERAGE
96" MINIMUM
LPA
12" (MAX)
(305mm MAX)
4"
(102mm)
NOTE: MEASUREMENTS
SHOWN ARE TO THE
CLOSEST EDGE OF THE
DETECTOR.
4"
(102mm)
NEVER
HERE
ACCEPTED
HERE
6"
(152mm)
WALL MOUNTED
SMOKE/HEAT
DETECTOR
FINISHED WALL
48" MAX (ADA)
42" MIN/48" MAX (NFPA)
NFPA 72 2016 EDITION
FINISHED
FLOOR
DOOR
WIDTH
LESS 3"
(76mm)
TO EXIT
DOOR
5' (MAX.)
(1524mm)
MAGNETIC DOOR
HOLDER
MANUAL PULL
STATION
FIRE
PHONE
JACK
80" MIN (NFPA)
NFPA 72 2016 EDITION
NOTE:
REFER TO THE PROPER DEVICE INSTALLATION
INSTRUCTIONS FOR BACKBOX MOUNTING HEIGHT
96" MAX (NFPA)
ABOVE FINISHED FLOOR
NFPA 72 2016 EDITION
AUDIO/VISUAL AND
VISUAL ONLY
DEVICES
A/C SUPPLY OR
RETURN
DIFFUSER
3' (MIN.)
(914mm MIN.)
CEILING MOUNTED
SMOKE/HEAT DETECTOR
SYNCHRONIZE MORE
THAN TWO APPLICANCE
IN ANY FIELD OF VIEW.
NFPA 72 2016 EDITION
(SECTION 18.5.5.4.2)
FIRE ALARM
CEILING
SIDE WALL
FIRE FIRE
90" MIN (NFPA)
NFPA 72 2016 EDITION
100" MAX (NFPA)
ABOVE FINISHED FLOOR
NFPA 72 2016 EDITION
AUDIO
ONLY
DEVICES
FIRE
TOP OF LENS
FIRE SPRINKLER
(ABOVE OR BELOW CEILING
12" (MIN.)
LPA
MANUAL PULL STATION
DATA IN
FROM FACP OR
PREVIOUS DEVICE (+)
(-)
-
AUDIBLE APPLIANCE
SYNC
MODULE
DATA OUT
TO NEXT DEVICE
(+)
(-)
-+
FROM
FCP OR
RPS
-
++ADDRESS42310769854235760198LOOP--
+
-
-
+
-
+
-
+
-
+
VISUAL APPLIANCE
-
+
-
-
++
-
+
-
UL LISTED
47Ohm EOL
RESISTOR
(+)
STANDARD DETECTOR BASE
STRIP GAGEFROM PREVIOUS
ADDRESSABLE
DEVICE OR
CONTROL PANEL
DATA
IN (+)
TERMINAL 2
DATA
IN(-)
TERMINAL 1
TO NEXT
ADDRESSABLE
DEVICE1
++
DATA
OUT(+)
SHIELD2
3 +
DATA
OUT(-)
(-)
TO 120VAC
(-)(-)
2(-)
161415
1(+)
TO HVAC
CONTROL
A/C UNIT SHUT-DOWN
DATA IN
FROM FACP OR
PREVIOUS DEVICE (+)(+)
DATA OUT
TO NEXT DEVICE
SYNC
MODULE
FROM
FCP OR
RPS
UL LISTED
47Ohm EOL
RESISTOR
UDACT
1/2"C., 2 #12 & 1 #12 GRD.
1"C., WITH FIRE ALARM
CONDUCTORS TYP. U.O.N.
FACPFAPS
1/2"C., 2 #12 & 1 #12 GRD.
FCPS OR VEC QTY.
AS REQUIRED
FATCFATC
3/4"C., WITH
TELEPHONE - DATA
CONDUCTORS AS
REQUIRED TO MPOE.
SECONDARY PHONE LINE
PRIMARY PHONE LINE
1/2"C., WITH FIRE
ALARM CONDUCTORS
JJ
LPA
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
FIRE ALARM
DIAGRAMS AND
DETAILS
FA4.00
08/01/2025
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDING1" = 1'-0" HEAT DEVICE MOUNTING DETAIL 15 1" = 1'-0"
TYPICAL DEVICE MOUNTING DETAILS 03
1" = 1'-0"
TYPICAL DEVICE WIRING DIAGRAMS 011" = 1'-0"
FIRE ALARM SYSTEM SCHEMATIC 13
1" = 1'-0"
TYPICAL FIRE SPRINKLER SYSTEM CONNECTION DETAIL 14
FACP
N,S
(TY.)
(TY.)
20A/1
FA-1101
FA-1102
FA-1108
FA-1106
FA-1110
BACKFLOW
(SEE ELECTERICAL SITE PLAN, SHEET E1.11)TT
FA-1107
FIRE ALARM CONTROL ANEL
AND POWER SULY PANEL IN
ELECT. ROOM 104
ANN
15cd
N1-1
WP
N1-2
75cd
N1-3
75cd
N1-4 N1-12
75cd
N1-5
WP
330'
7.02%FA-1105
FA-1104FA-1103
15cd
N2-1 N2-2 N2-3 N2-4 N2-6
15cd
N2-5
15cd 15cd
30cd
N3-1 N3-2 N3-3 N3-4 N3-6
75cd
N3-5
15cd 75cd 75cd75cd
Z
Z1-1Z1-2Z1-3Z1-4Z1-5Z1-6Z1-13Z1-14Z1-15
Z1-16Z1-17
Z1-18Z1-21 Z1-20
Z1-19
Z1-23 Z1-22
Z1-26
Z1-25
Z1-24
Z1-27
Z
TW
B
Z2-1
Z
S1-1 S1-2 S1-3 S1-4 S1-6 S1-13S1-5 S1-14
S2-1 S2-2 S2-3 S2-4 S2-6S2-5
S3-1 S3-2 S3-3 S3-4 S3-6S3-5
75cd 30cd
N1-6S1-7
15cd
N1-7S1-8
15cd
N1-8S1-9
15cd 75cd
N1-10S1-11
15cd
N1-9S1-10
E.O.L.
SK. CKT.
15cd 15cd
75cd
N4-1 N4-2 N4-3 N4-4
75cd
N4-5
75cd 75cd 75cd
S3-7 S3-8 S3-9 S3-10 S3-11
E.O.L.
STB. CKT.
350'
5.25%
E.O.L.
SK. CKT.
STB. CKT.
500'
7.47%
E.O.L.
SK. CKT.
STB. CKT.
S
FA-1111
Z2-2
Z2-3
Z2-4Z2-5Z2-6
Z2-7
Z2-8
Z2-9
Z2-10
Z2-11
Z2-12
Z2-13Z2-14
Z2-15
Z2-16
Z2-17Z2-18
Z2-19
Z2-20
Z2-21
N
FAPS
T
PIV
CKT# LPA-XX
Z1-7Z1-8Z1-9
E.O.L.
STB. CKT.15cd
N1-11S1-12
N,S
N,S
440'
3.30%
Z1-28
Z1-30
Z1-29
Z1-31
Z1-32
Z1-33
Z1-34 Z1-35
Z1-36
Zc
FSD
Z2-22
Z2-23Z2-24
Z2-25
Z2-38
Z2-39Z2-37
Z2-36
Z2-34
Z2-35Z2-33
Z2-32
Z2-30
Z2-31Z2-29
Z2-28
Z2-26
Z2-27
Z6-1Z6-2Z6-3Z6-4
Z6-5
Z6-6Z6-7
Z6-8
Z6-9Z6-10
Z6-11
Z6-12Z6-13Z6-14Z6-15
Z6-16
Z6-17Z6-18
Z6-19
Z6-20Z6-21
Zc
FSDZ6-22
Z6-23Z6-24
Zc
FSD
Zc
FSD
Zc
FSD
Zc
FSD
Zc
FSD
Zc
FSD
Zc
FSD
Zc
AC-2-7
FA-1112
Z3-2 Z3-1Z3-4 Z3-3Z3-6 Z3-5Z3-7Z3-8Z3-9
ZmZcZcZc
Z3-10Z3-11Z3-12Z3-13Z3-14Z3-15
Z
Z3-16
TWZc
AHU-1
Z3-17
Z3-18
Z3-19
Z3-20
Z3-21Z3-22
Zc
AHU-3
Zc
AHU-2
Z3-23Z3-24Z3-25
Zc
AHU-5
Zc
AHU-4
Z3-26 Z3-28
Z3-27
Z3-30
Z3-29
Z3-31
Z3-32
Z3-33 Z3-34
Z3-35
Z3-36 Z3-37
Zc
AC-1-5
Zc
FSD
Z1-37
Z2-40
Z2-41
Zc
FSD
Z2-42
Z6-26
Z3-38 Z3-39
Zc
FSD
SAMPLE RISER DIAGRAM
C,P,S
C
2ZU
NOT FOR REGULATORY APPROVAL,
PERMITTING OR CONSTRUCTION
Developed forJob Number
Date Published
Checked By
ScaleRevisionDateARCHITECTURE ENGINEERING INTERIORS
LANDSCAPE ARCHITECTURE PLANNING
949-261-1001 Office
949-260-1190 Fax
LPADesignStudios.com
5301 California Avenue,
Suite 100
Irvine, California 92617
SubmittalDateThis document and all other project documents, ideas, aesthetics and designs incorporated
therein are instruments of service. All project
documents are copyright protected, are the
property of LPA, Inc. (LPA) and cannot be lawfully
used in whole or in part for any project or purpose
except as set forth in the contractual agreement
between LPA and its Client. The unauthorized
disclosure and/or use of the project documents
(including the creation of derivative works), may
give rise to liability for copyright infringement,
unlawful disclosure, use or misappropriation of
property rights held by LPA. The unauthorized
use of the project documents will give rise to the
recovery of monetary losses and damages
including attorney fees and costs for which the
unauthorized user will be held liable.
Project documents describe the design intent of
the work and are not a representation of as-built
or existing conditions. LPA is not responsible for
any discrepancies between the project documents
and the existing conditions.
© LPA, Inc.SCHEMATIC DESIGN10/27/202250% DESIGN DEVELOPMENT 12/02/2022100% DESIGN DEVELOPMENT 01/06/202330% CONSTRUCTION DOCS 02/10/202395% PRICING SET08/01/2025COLUMBIA WAYDOWNEY, CA 90242CITY OF DOWNEY3055401
FIRE ALARM RISER
DIAGRAMS
FA5.00
08/01/2025
LPASPACE SHUTTLE EXHIBIT AND EDUCATIONBUILDINGN.T.S
FIRE ALARM RISER DIAGRAM 1
1.NOTIFICATION DEVICES IN ROOMS CONTAINING (2) OR MORE AUDIBLE AND/OR (2) OR MORE VISUAL DEVICES SHALL BE SYNCHRONIZED PER N.F.P.A. 72, 2016 EDITION (WITH CALIFORNIA AMENDMENTS). THIS SHALL
INCLUDE AUDIBLE AND VISUAL DEVICES LOCATED IN ADJACENT/ADJOINING SPACES.
2.DO NOT DEVIATE FROM CONDUIT RUNS AS SHOWN ON FLOOR PLANS WITHOUT PRIOR APPROVAL FROM SYSTEM SUPPLIER/ENGINEER.
FACTORS SUCH AS EXCESSIVE VOLTAGE DROP, ADDITIONAL PARTS, ENGINEERING, ETC. THAT ARE A RESULT OF CONDUIT RUN DEVIATIONS SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR.
3.DETECTORS SHALL NOT BE LOCATED IN A DIRECT AIR-FLOW , NOT CLOSER THAN 3 FEET FROM ANY SUPPLY DIFFUSER.
4.FIRE ALARM SYSTEM AUDIBILITY SHALL NOT BE LESS THAN 15db ABOVE AMBIENT NOISE LEVELS AND MAINTAINING A MINIMUM OF 75db THROUGH OUT ALL AREAS OF ALARM.
5.FIRE ALARM SYSTEM AUDIBILITY SIGNAL SHALL MEET EMERGENCY EVACUATION SIGNAL AS DEFINED PER ANSI S3.41 (TEMPORAL PATTERN).
6.THE EXISTING CAMPUS FIRE ALARM SYSTEM SHALL BE MAINTAINED AND OPERATIONAL AT ALL TIMES DURING ALTERATIONS AND CONSTRUCTION.
WHEN PORTIONS OF THE SYSTEM REQUIRE ALTERATIONS, THE
REMAINDER OF THE SYSTEM SHALL BE KEPT IN SERVICE. IF NECESSARY
TO SHUT DOWN ENTIRE FIRE ALARM SYSTEM, A FIRE WATCH SHALL BE
KEPT ON SITE UNTIL THE FIRE ALARM SYSTEM IS RETURNED TO OPERATIONAL SERVICE. LOCAL FIRE AUTHORITY SHALL BE NOTIFIED 48 HOURS IN ADVANCE OF ANY SHUT DOWN.
7.CONTROL PANELS, REMOTE ANNUNCIATORS SHALL BE INSTALLED 48" TO TOP OF DEVICE.
GENERAL NOTES FA RISER DIAGRAM
KEYNOTES
ITEM DESCRIPTION
FA-1101 ZONEABLE/ADDRESSIBLE CIRCUIT. PROVIDE 2#16 TWISTED PAIR PER CIRCUIT, TYPICAL.
FA-1102 NOTIFICATION CIRCUIT, PROVIDE 2#12 PER CIRCUIT, TYPICAL.
FA-1103 CANDELA RATING OF STROBE DEVICES.
FA-1104 DISTANCE TO END OF LINE (EOL) DEVICE.
FA-1105 WORST-CASE VOLTAGE DROP PERCENTAGE.
FA-1106 PROVIDE 3/4"C. WITH 2#12 GRD. DEDICATED CIRCUIT FOR FIRE ALARM EQUIPMENT. THIS CIRCUIT SHALL BE ENERGIZED FROM THE COMMON USE AREA PANEL AND SHALL HAVE NO OTHER OUTLETS. PROVIDE 20 AMP, 1-POLE
CIRCUIT BREAKER WITH APPROVED LOCK-ON DEVICE TO BLOCK THE HANDLE IN "ON" POSITION. PROVIDE RED INDICATOR IN PANELBOARD AND LABEL "FIRE ALARM CIRCUIT CONTROL" AS REQUIRED. CIRCUIT ID TO BE LABELED AT FIRE ALARM PANEL/EXTENDER. MATCH A.I.C. RATING OF DEVICES CURRENTLY USED.
PROVIDE ALL REQUIRED MOUNTING HARDWARE.
FA-1107 FIRE ALARM ANNUNCIATOR PANEL. VERIFY WITH DISTRICT REPRESENTATIVE, A.H.J. AND ARCHITECT FOR EXACT LOCATION.
FA-1108 PROVIDE (2) DEDICATED PHONE LINES (LAND LINES) FOR FIRE ALARM SYSTEM MONITORING. CONTRACTOR TO SUPPLY UDACT (UNIVERSAL DIGITAL ALARM COMMUNICATOR TRANSMITTER) WHEN NOT SUPPLIED WITH CONTROL PANEL.
FA-1110
FA-1111
FA-1112
SYMBOL (NTS)QTY. DESCRIPTIONEQUIPMENT QUANTITY TABLEHORIZONTAL LIFELINE (HLL)1THIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF OLYMPIQUE FACADE ACCESS CONSULTING. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION OR DISCLOSURE OF THE DRAWING, DOCUMENTS AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF OLYMPIQUE FACADE ACCESS CONSULTING.Y:\CLIENTS\LPA\Space Shuttle Exhibit\Space Shuttle Exhibit - OFAC\NC-24-028 DD R2.1 100%.dwg 7/31/2025 7:31:50 AM FM0.00 COVER SHEETFM2.01 FIRST FLOOR PLANFM2.03 ROOF PLANFM3.01 EXTERIOR ELEVATIONSFM3.02 EXTERIOR ELEVATIONSFM3.03 EXTERIOR ELEVATIONSFM3.04 EXTERIOR ELEVATIONSFM3.21 WALL SECTIONSFM5.03 INTERIOR ELEVATIONSFM5.04 INTERIOR ELEVATIONSFM9.01 DETAILSFM9.02 DETAILSTHIS SCOPE OF WORK INCLUDES THE DESIGN OF A NEW WINDOW CLEANING AND FACADE ACCESSEQUIPMENT SYSTEM TO MEET CURRENT REGULATIONS. EQUIPMENT INCLUDES, BUT IS NOT LIMITEDTO THE FOLLOWING:1. HORIZONTAL LIFELINE (HLL)THE EQUIPMENT SHOWN ON THESE DRAWINGS IS CONCEPTUAL. THE ACTUAL SYSTEM ANDEQUIPMENT SHALL BE DESIGNED, FABRICATED, AND INSTALLED BY AWARDED CONTRACTOR. ALLWORK SHALL BE PERFORMED IN CONFORMANCE WITH THE "GENERAL NOTES" SECTION OF THISSHEET AND ACCOMPANYING SPECIFICATIONS.ABBREVIATIONSSHEET INDEXPROJECT DESCRIPTIONREFER TO SPECIFICATION SECTION 112423"EXTERIOR BUILDING MAINTENANCEEQUIPMENT" FOR ADDITIONAL DESIGNCRITERIA AND PERFORMANCE REQUIREMENTSFOR EQUIPMENT THAT IS SHOWN, AND NOTSHOWN, ON THESE DRAWINGSA AMPAFF ABOVE FINISHED FLOORAFR ABOVE FINISHED ROOFARCH ARCHITECTURALASSY ASSEMBLYBMU BUILDING MAINTENANCE UNITB.O. BOTTOM OFB.O.S. BOTTOM OF STRUCTURECDA CONTROLLED DESCENT APPARATUSCL CENTERLINECONC CONCRETEDIA DIAMETER(E) EXISTINGEA EACHEOR ENGINEER OF RECORDFOW FACE OF WALLETFE ETHYLENE TETRAFLUOROETHYLENE(POLYMER USED FOR PNEUMATICROOF PANELS)GC GENERAL CONTRACTORGL GRIDLINEHB HOSE BIBBHDG HOT DIPPED GALVANIZEDHLL HORIZONTAL LIFE LINEI.D. INNER DIAMETERISF INSIDE FACEL.F. LINEAR FOOT (SURFACE LENGTH)MAX MAXIMUMMFR MANUFACTURERMIN MINIMUMMTL MATERIALNTS NOT TO SCALE(N) NEWNTS NOT TO SCALENIC NOT IN CONTRACTO.C. ON CENTERO.D. OUTER DIAMETEROPP OPPOSITEORIG ORIGINALQTY QUANTITYREF REFERENCESIM SIMILARSTRUC STRUCTURALT.O. TOP OFT.O.P. TOP OF PARAPETT.O.R. TOP OF ROOFT.O.S. TOP OF STRUCTURETYP TYPICALUNO UNLESS NOTED OTHERWISEUSM UNSCHEDULED MAINTENANCEV VOLTVIF VERIFY IN FIELDWFP WATER FED POLESPACE SHUTTLE EXHIBIT AND EDUCATION BUILDINGDOWNEY, CA 90242100% Design DevelopmentEXTERIOR BUILDING MAINTENANCE (EBM) EQUIPMENTREVIEW ONLY - NOT FOR CONSTRUCTION CONSULTANT NOTES1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS IN FIELD PRIOR TO FABRICATION ANDINSTALLATION OF MATERIALS AND ASSEMBLIES.2. ALL LOADS SPECIFIED ON THESE DRAWINGS ARE WORKING LOADS, UNLESS NOTEDOTHERWISE. ALL COMPONENTS SHOWN ON THESE DRAWINGS SHALL BE DESIGNED TOSUPPORT THE WORKING LOADS SPECIFIED WITH A MINIMUM FACTOR OF SAFETY OF FOUR (4)UNLESS NOTED OTHERWISE, AGAINST DEFORMATION OR FAILURE.3. ALL STEEL ASSEMBLIES SHALL BE HOT DIP GALVANIZED AFTER FABRICATION AND PRIOR TOINSTALLATION.4. ALL EXPOSED FIELD WELDS SHALL BE APPLIED WITH A COLD GALVANIZING SPRAY OREQUIVALENT CORROSIVE-RESISTANT SUBSTANCE.5. PROVIDE SPECIAL INSPECTIONS OF ADHESIVE ANCHOR INSTALLATIONS, FIELD WELDING, ETC.AS REQUIRED BY BUILDING CODE.6. OPERATING PROCEDURES OUTLINE SHEET (OPOS) AS REQUIRED BY CAL/OSHA FOR THISPROJECT IS NOT INCLUDED IN THIS SCOPE.7. CONTROLLED DESCENT APPARATUS, WORKER'S SAFETY LINES, ETC. ARE NOT INCLUDED INTHIS SCOPE.8. THE CONTRACTOR SHALL BEAR RESPONSIBILITY FOR PROVIDING ALL WORK AND MATERIALSIN ACCORDANCE WITH APPLICABLE CODES AND STANDARDS (FEDERAL, STATE, AND COUNTY),HAVING JURISDICTION OVER SUCH WORK. ALL APPLICABLE REQUIREMENTS IN THESEREGULATIONS SHALL BE FOLLOWED THE SAME AS IF NOTED ON THE DRAWINGS.9. THE CONTRACTOR AND SUBCONTRACTORS SHALL PERFORM ALL WORK IN STRICTCOMPLIANCE WITH THE CALIFORNIA OCCUPATION SAFETY AND HEALTH ACT.10. THE CONTRACTOR SHALL VERIFY THAT REQUIRED CLEARANCES ARE OBTAINED PRIOR TOCOMMENCEMENT OF THE WORK.11. THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING THE ACCURACY OF ALL DIMENSIONS FORBOTH EXISTING AND PROPOSED WORK PRIOR TO SYSTEM FABRICATION. CONTACTCONSULTANT IF ANY DIMENSIONS OR EXISTING BUILDING CONSTRUCTION VARIES FROM WHATIS SHOWN ON THESE DRAWINGS.12. AT ALL EQUIPMENT INSTALLATIONS, CONTRACTOR TO VERIFY THICKNESS OF ROOF SLAB,ROOFING MATERIAL, OR WALL CONSTRUCTION PRIOR TO EQUIPMENT FABRICATION TO ENSUREADEQUATE CLEARANCE WILL BE OBTAINED UPON INSTALLATION. CONTACT CONSULTANT IFADEQUATE CLEARANCES CANNOT BE OBTAINED.13. COORDINATION WITH OTHER TRADE WORK THAT INTERFACES OR IMPACTS/IS IMPACTED BYTHIS SCOPE IS MANDATORY.14. THE STRUCTURAL ENGINEER OF RECORD FOR THE OVERALL PROJECT SHALL ENSURE THATTHE AFFECTED PARTS OF THE BUILDING HAVE THE CAPABILITY OF SUSTAINING THE LOADSIMPOSED BY THE EQUIPMENT AND WORKING CONDITIONS SHOWN IN THESE DRAWINGS.15. CONSULTANT WILL NOT SUPERVISE, DIRECT, CONTROL OF HAVE AUTHORITY OVER OR BERESPONSIBLE FOR CONTRACTOR'S MEANS, METHODS, TECHNIQUES, SEQUENCES ORPROCEDURES OF CONSTRUCTION, OR THE SAFETY PRECAUTIONS AND PROGRAMS INCIDENTTHERETO, OR FOR ANY FAILURE OF CONTRACTOR TO COMPLY WITH LAWS AND REGULATIONSAPPLICABLE TO THE FURNISHING OR PERFORMANCE OF THE WORK.16. THE WORKING LOADS SHOWN IN THESE DRAWINGS ARE SERVICE LEVEL AND DO NOT INCLUDEFACTORS FOR DYNAMIC LOADS WHICH ARE IMPOSED TO THE BUILDING BY THE EQUIPMENTAND WORKING CONDITIONS SHOWN IN THESE DRAWINGS.17. THE FACTORED LOADS SHOWN IN THESE DRAWINGS PERTAIN ONLY TO THE REQUIRED"EQUIPMENT" DESIGN FACTOR OF SAFETY PER THE APPLICABLE REGULATIONS AND ARE NOTNECESSARILY CONSIDERED TO BE LOADS IMPOSED TO THE BUILDING BY THE EQUIPMENT.18. OPERABLE WINDOWS WITH WASHABILITY HARDWARE REQUIREMENTS SHOWN ON THESEDRAWINGS ARE BASED ON WINDOW TYPES SHOWN ON THE ARCHITECTURAL DRAWINGSPROVIDED. VERIFY ACTUAL WINDOW TYPES WITH ARCHITECTURAL DRAWINGS AND ANY FIELDCHANGES. NOTIFY FACADE ACCESS CONSULTANT OF ANY CHANGES OR DISCREPANCIES.19. WINDOWS AT/OR ABOVE THE WATER FED POLE ACCESS HEIGHT LIMIT THAT ARE NOTINDICATED ON THESE DRAWINGS AS REQUIRING WASHABILITY HARDWARE HAVE BEENINTERPRETED BY THE FACADE ACCESS CONSULTANT AS ACCESSIBLE FOR WINDOW CLEANINGVIA "GROUND OPERATIONS" BY STANDING ON A SAFE SURFACE (I.E. BALCONY). ANY SUCHWINDOW DETERMINED BY THE ARCHITECT OR GENERAL CONTRACTOR TO NOT MEET THISCRITERIA SHALL BE CONSIDERED AS ONE REQUIRING WASHABILITY HARDWARE AS SHOWN ONTHESE DRAWINGS OR REQUIRE FURTHER REVIEW. NOTIFY THE FACADE ACCESS CONSULTANTOF ANY CHANGES OR DISCREPANCIES.20. PERMANENT ACCESS TO ALL ELEVATED WORK LOCATIONS IS REQUIRED PER CCR T8 GISO3270. THIS INCLUDES BUT IS NOT LIMITED TO ANY ROOF, INCLUDING STAIR AND ELEVATORROOFS.NOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTIONDeveloped forJob NumberDate PublishedChecked ByScaleRevision Date ARCHITECTURE ENGINEERING INTERIORSLANDSCAPE ARCHITECTURE PLANNING949-261-1001 Office949-260-1190 FaxLPADesignStudios.com5301 California Avenue,Suite 100Irvine, California 92617Submittal Date This document and all other project documents,ideas, aesthetics and designs incorporatedtherein are instruments of service. All projectdocuments are copyright protected, are theproperty of LPA, Inc. (LPA) and cannot be lawfullyused in whole or in part for any project or purposeexcept as set forth in the contractual agreementbetween LPA and its Client. The unauthorizeddisclosure and/or use of the project documents(including the creation of derivative works), maygive rise to liability for copyright infringement,unlawful disclosure, use or misappropriation ofproperty rights held by LPA. The unauthorizeduse of the project documents will give rise to therecovery of monetary losses and damagesincluding attorney fees and costs for which theunauthorized user will be held liable.Project documents describe the design intent ofthe work and are not a representation of as-builtor existing conditions. LPA is not responsible forany discrepancies between the project documentsand the existing conditions.© LPA, Inc.SCHEMATIC DESIGN 10/27/2022 50% DESIGN DEVELOPMENT 12/02/2022
100% DESIGN DEVELOPMENT 01/06/2023
30% CONSTRUCTION DOCS 02/10/2023 COLUMBIA WAY
DOWNEY, CA 90242
CITY OF DOWNEY
SPACE SHUTTLE EXHIBIT AND EDUCATION
BUILDING 26429 Rancho Parkway South #145, Lake Forest, CA 92630Phone: 949.309.2820 Fax: 949.613.5905 www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPCOVER SHEETFM0.00
UPUP1122334566778899AAFFF.2F.210101212HHB.5DEEF.1F.1GG4.94.9G.5CB.27.47.4BBEEFFA.1BB4.24.81.11.15.25.86.96.9D.6AACCDDA.2A.3D.8D.9D.98.98.97.97.97.16.76.1B.1GROUND LEVEL(±0'-0")GROUND LEVEL(±0'-0")GROUND LEVEL(±0'-0")GROUND LEVEL(±0'-0")04FM3.0202FM3.0304FM3.0104FM3.0310FM3.0402FM3.0416FM3.0418FM3.04GROUND LEVEL(±0'-0")GROUNDOPERATIONSGROUNDOPERATIONSGROUNDOPERATIONS01FM3.2101FM5.0302FM5.0302FM5.0401FM5.043333HBHBHBHBGROUNDOPERATIONSGROUNDOPERATIONSIF EQUIPMENT IS LOCATED ONROOF, PERMANENT SAFEACCESS WILL BE REQUIREDHBLEVEL 1(±0'-0")GROUNDOPERATIONSGROUNDOPERATIONSLEVEL 1(±0'-0")ROOF HATCH REQUIRES TO BE DESIGNED INCOMPLIANCE WITH CCR T8 GISO ARTICLE 2SECTION 3212 (a)(3) FOR FALL PROTECTION,SEE DETAIL 1/FM9.01KEYNOTESGUARDRAIL 42" MIN TO 45" MAX OR PARAPET 42" MINTO 72" MAX PER CCR T8 GISO ARTICLE 6 SECTION3294(c)(1), SEE DETAIL 2/FM9.02DANGER ZONE (PARAPET www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPFIRST FLOORPLANFM2.01TRUE NORTHNPROJECT NORTH
112233445566778899AAFF10101/2" / 12"DDEE54'-8"49'-6 3/4"54'-8"49'-6 3/4"CCBBGROUND LEVEL(±0'-0")GROUND LEVEL(±0'-0")GROUND LEVEL(±0'-0")02FM3.0304FM3.0304FM3.0210FM3.0402FM3.0416FM3.04GROUND LEVEL(±0'-0")101FM3.2101FM5.0302FM5.0302FM5.0401FM5.0412' MAX. TYP.6' MIN; TYP.6' MIN; TYP.6' MIN; TYP.6' MIN; TYP.STEEL COLUMNS BELOWROOF OVERHANG,TYP.DANGER ZONE LINE 6' AWAYFROM UNPROTECTEDEDGE,TYP.DANGER ZONE LINE 6' AWAYFROM UNPROTECTEDEDGE,TYP.DANGER ZONE LINE 6' AWAYFROM UNPROTECTEDEDGE,TYP.DANGER ZONE LINE 6' AWAYFROM UNPROTECTEDEDGE,TYP.2'-6" MAXROOF LEVEL(±54'-0")333333PROVIDE SAFE ANDPERMANENT ROOF ACCESS12' MAX. TYP.12' MAX. TYP.12' MAX. TYP. 12' MAX. TYP.12' MAX. TYP.
12' MAX. TYP.12' MAX. TYP.12' MAX. TYP.12' MAX. TYP.GROUND LEVEL(±0'-0")04FM3.01ROOF HATCH REQUIRES TO BE DESIGNED INCOMPLIANCE WITH CCR T8 GISO ARTICLE 2SECTION 3212 (a)(3) FOR FALL PROTECTION,SEE DETAIL 1/FM9.01KEYNOTESGUARDRAIL 42" MIN TO 45" MAX OR PARAPET 42" MINTO 72" MAX PER CCR T8 GISO ARTICLE 6 SECTION3294(c)(1), SEE DETAIL 2/FM9.02DANGER ZONE (PARAPET www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPROOF PLANFM2.03TRUE NORTHNPROJECT NORTH
01 - FLOOR0'-0"02 - FLOOR15'-0"1234567894.24.81.15.25.8VARIEST.O. EAVE2FM9.01HORIZONTAL LIFE LINEANGLED WALL1FM9.02GROUND OPERATIONS1FM9.01ROOF HATCH48' MAX.WFP TYP. ZONEMETAL PANELS DO NOT REQUIRE ANYSERVICING, MAINTENANCE, OR CLEANINGAFTER INSTALLATION PERMANUFACTURER GUIDELINES.LEGENDWINDOWS TO BE ACCESSED FROM EXTERIORBY GROUND OPERATIONS (HIGH-REACH POLE;ASSUMING NO POWER LINES WITHIN RANGEOF MOTION), SEE DETAIL 1/FM9.02Y:\CLIENTS\LPA\Space Shuttle Exhibit\Space Shuttle Exhibit - OFAC\NC-24-028 DD R2.1 100%.dwg 7/31/2025 7:32:03 AMTHIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF OLYMPIQUE FACADE ACCESS CONSULTING. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION OR DISCLOSURE OF THE DRAWING, DOCUMENTS AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF OLYMPIQUE FACADE ACCESS CONSULTING.NOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTIONDeveloped forJob NumberDate PublishedChecked ByScaleRevision Date ARCHITECTURE ENGINEERING INTERIORSLANDSCAPE ARCHITECTURE PLANNING949-261-1001 Office949-260-1190 FaxLPADesignStudios.com5301 California Avenue,Suite 100Irvine, California 92617Submittal Date This document and all other project documents,ideas, aesthetics and designs incorporatedtherein are instruments of service. All projectdocuments are copyright protected, are theproperty of LPA, Inc. (LPA) and cannot be lawfullyused in whole or in part for any project or purposeexcept as set forth in the contractual agreementbetween LPA and its Client. The unauthorizeddisclosure and/or use of the project documents(including the creation of derivative works), maygive rise to liability for copyright infringement,unlawful disclosure, use or misappropriation ofproperty rights held by LPA. The unauthorizeduse of the project documents will give rise to therecovery of monetary losses and damagesincluding attorney fees and costs for which theunauthorized user will be held liable.Project documents describe the design intent ofthe work and are not a representation of as-builtor existing conditions. LPA is not responsible forany discrepancies between the project documentsand the existing conditions.© LPA, Inc.SCHEMATIC DESIGN 10/27/2022 50% DESIGN DEVELOPMENT 12/02/2022
100% DESIGN DEVELOPMENT 01/06/2023
30% CONSTRUCTION DOCS 02/10/2023 COLUMBIA WAY
DOWNEY, CA 90242
CITY OF DOWNEY
SPACE SHUTTLE EXHIBIT AND EDUCATION
BUILDING 26429 Rancho Parkway South #145, Lake Forest, CA 92630Phone: 949.309.2820 Fax: 949.613.5905 www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPEXTERIORELEVATIONSFM3.01Scale: 1/8" = 1'-0"EXHIBIT HALL ELEVATION - NORTH04
01 - FLOOR0'-0"02 - FLOOR15'-0"1/2"12"BBEEFFAACCDDVARIEST.O. EAVE1FM9.02GROUND OPERATIONS48' MAX.WFP TYP. ZONEMETAL PANELS DO NOT REQUIRE ANYSERVICING, MAINTENANCE, OR CLEANINGAFTER INSTALLATION PERMANUFACTURER GUIDELINES.LEGENDWINDOWS TO BE ACCESSED FROM EXTERIORBY GROUND OPERATIONS (HIGH-REACH POLE;ASSUMING NO POWER LINES WITHIN RANGEOF MOTION), SEE DETAIL 1/FM9.02Y:\CLIENTS\LPA\Space Shuttle Exhibit\Space Shuttle Exhibit - OFAC\NC-24-028 DD R2.1 100%.dwg 7/31/2025 7:32:08 AMTHIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF OLYMPIQUE FACADE ACCESS CONSULTING. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION OR DISCLOSURE OF THE DRAWING, DOCUMENTS AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF OLYMPIQUE FACADE ACCESS CONSULTING.NOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTIONDeveloped forJob NumberDate PublishedChecked ByScaleRevision Date ARCHITECTURE ENGINEERING INTERIORSLANDSCAPE ARCHITECTURE PLANNING949-261-1001 Office949-260-1190 FaxLPADesignStudios.com5301 California Avenue,Suite 100Irvine, California 92617Submittal Date This document and all other project documents,ideas, aesthetics and designs incorporatedtherein are instruments of service. All projectdocuments are copyright protected, are theproperty of LPA, Inc. (LPA) and cannot be lawfullyused in whole or in part for any project or purposeexcept as set forth in the contractual agreementbetween LPA and its Client. The unauthorizeddisclosure and/or use of the project documents(including the creation of derivative works), maygive rise to liability for copyright infringement,unlawful disclosure, use or misappropriation ofproperty rights held by LPA. The unauthorizeduse of the project documents will give rise to therecovery of monetary losses and damagesincluding attorney fees and costs for which theunauthorized user will be held liable.Project documents describe the design intent ofthe work and are not a representation of as-builtor existing conditions. LPA is not responsible forany discrepancies between the project documentsand the existing conditions.© LPA, Inc.SCHEMATIC DESIGN 10/27/2022 50% DESIGN DEVELOPMENT 12/02/2022
100% DESIGN DEVELOPMENT 01/06/2023
30% CONSTRUCTION DOCS 02/10/2023 COLUMBIA WAY
DOWNEY, CA 90242
CITY OF DOWNEY
SPACE SHUTTLE EXHIBIT AND EDUCATION
BUILDING 26429 Rancho Parkway South #145, Lake Forest, CA 92630Phone: 949.309.2820 Fax: 949.613.5905 www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPFM3.02EXTERIORELEVATIONSScale: 1/8" = 1'-0"EXTERIOR ELEVATION - NORTHWEST04
LEGENDWINDOWS TO BE ACCESSED FROM EXTERIORBY GROUND OPERATIONS (HIGH-REACH POLE;ASSUMING NO POWER LINES WITHIN RANGEOF MOTION), SEE DETAIL 1/FM9.0201 - FLOOR0'-0"02 - FLOOR15'-0"1234567894.24.81.15.25.8VARIEST.O. EAVE2FM9.01HORIZONTAL LIFE LINE1FM9.01ROOF HATCHMETAL PANELS DO NOT REQUIRE ANYSERVICING, MAINTENANCE, OR CLEANINGAFTER INSTALLATION PERMANUFACTURER GUIDELINES.48' MAX.WFP TYP. ZONE01 - FLOOR0'-0"02 - FLOOR15'-0"AFDECBD.954'-8"T.O. HIGH EAVE49'-6 3/4"T.O. LOW EAVE1FM9.02GROUND OPERATIONS2FM9.01HORIZONTAL LIFE LINE48' MAX.WFP TYP. ZONEMETAL PANELS DO NOT REQUIRE ANYSERVICING, MAINTENANCE, OR CLEANINGAFTER INSTALLATION PERMANUFACTURER GUIDELINES.Y:\CLIENTS\LPA\Space Shuttle Exhibit\Space Shuttle Exhibit - OFAC\NC-24-028 DD R2.1 100%.dwg 7/31/2025 7:32:13 AMTHIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF OLYMPIQUE FACADE ACCESS CONSULTING. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION OR DISCLOSURE OF THE DRAWING, DOCUMENTS AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF OLYMPIQUE FACADE ACCESS CONSULTING.NOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTIONDeveloped forJob NumberDate PublishedChecked ByScaleRevision Date ARCHITECTURE ENGINEERING INTERIORSLANDSCAPE ARCHITECTURE PLANNING949-261-1001 Office949-260-1190 FaxLPADesignStudios.com5301 California Avenue,Suite 100Irvine, California 92617Submittal Date This document and all other project documents,ideas, aesthetics and designs incorporatedtherein are instruments of service. All projectdocuments are copyright protected, are theproperty of LPA, Inc. (LPA) and cannot be lawfullyused in whole or in part for any project or purposeexcept as set forth in the contractual agreementbetween LPA and its Client. The unauthorizeddisclosure and/or use of the project documents(including the creation of derivative works), maygive rise to liability for copyright infringement,unlawful disclosure, use or misappropriation ofproperty rights held by LPA. The unauthorizeduse of the project documents will give rise to therecovery of monetary losses and damagesincluding attorney fees and costs for which theunauthorized user will be held liable.Project documents describe the design intent ofthe work and are not a representation of as-builtor existing conditions. LPA is not responsible forany discrepancies between the project documentsand the existing conditions.© LPA, Inc.SCHEMATIC DESIGN 10/27/2022 50% DESIGN DEVELOPMENT 12/02/2022
100% DESIGN DEVELOPMENT 01/06/2023
30% CONSTRUCTION DOCS 02/10/2023 COLUMBIA WAY
DOWNEY, CA 90242
CITY OF DOWNEY
SPACE SHUTTLE EXHIBIT AND EDUCATION
BUILDING 26429 Rancho Parkway South #145, Lake Forest, CA 92630Phone: 949.309.2820 Fax: 949.613.5905 www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPFM3.03EXTERIORELEVATIONSScale: 1/8" = 1'-0"EXTERIOR ELEVATION - EAST02Scale: 1/8" = 1'-0"EXTERIOR ELEVATION - SOUTH04
LEGENDWINDOWS TO BE ACCESSED FROM EXTERIORBY GROUND OPERATIONS (HIGH-REACH POLE;ASSUMING NO POWER LINES WITHIN RANGEOF MOTION), SEE DETAIL 1/FM9.0201 - FLOOR0'-0"344.9G.5OPEN TO BEYOND4.24.816'-6"T.O. HIGH EAVE14'-0"T.O. LOW EAVE1FM9.02GROUND OPERATIONSMETAL PANELS DO NOT REQUIRE ANYSERVICING, MAINTENANCE, OR CLEANINGAFTER INSTALLATION PERMANUFACTURER GUIDELINES.01 - FLOOR0'-0"VARIEST.O. EAVE1FM9.02GROUND OPERATIONSMETAL PANELS DO NOT REQUIRE ANYSERVICING, MAINTENANCE, OR CLEANINGAFTER INSTALLATION PERMANUFACTURER GUIDELINES.01 - FLOOR0'-0"345OPEN TO BEYOND4.9G.54.24.816'-6"T.O. HIGH EAVE14'-0"T.O. LOW EAVENO FACADE ACCESS REQUIRED AT THIS ELEVATIONMETAL PANELS DO NOT REQUIRE ANYSERVICING, MAINTENANCE, OR CLEANINGAFTER INSTALLATION PERMANUFACTURER GUIDELINES.01 - FLOOR0'-0"VARIEST.O. EAVENO FACADE ACCESS REQUIRED AT THIS ELEVATIONMETAL PANELS DO NOT REQUIRE ANYSERVICING, MAINTENANCE, OR CLEANINGAFTER INSTALLATION PERMANUFACTURER GUIDELINES.Y:\CLIENTS\LPA\Space Shuttle Exhibit\Space Shuttle Exhibit - OFAC\NC-24-028 DD R2.1 100%.dwg 7/31/2025 7:32:18 AMTHIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF OLYMPIQUE FACADE ACCESS CONSULTING. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION OR DISCLOSURE OF THE DRAWING, DOCUMENTS AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF OLYMPIQUE FACADE ACCESS CONSULTING.NOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTIONDeveloped forJob NumberDate PublishedChecked ByScaleRevision Date ARCHITECTURE ENGINEERING INTERIORSLANDSCAPE ARCHITECTURE PLANNING949-261-1001 Office949-260-1190 FaxLPADesignStudios.com5301 California Avenue,Suite 100Irvine, California 92617Submittal Date This document and all other project documents,ideas, aesthetics and designs incorporatedtherein are instruments of service. All projectdocuments are copyright protected, are theproperty of LPA, Inc. (LPA) and cannot be lawfullyused in whole or in part for any project or purposeexcept as set forth in the contractual agreementbetween LPA and its Client. The unauthorizeddisclosure and/or use of the project documents(including the creation of derivative works), maygive rise to liability for copyright infringement,unlawful disclosure, use or misappropriation ofproperty rights held by LPA. The unauthorizeduse of the project documents will give rise to therecovery of monetary losses and damagesincluding attorney fees and costs for which theunauthorized user will be held liable.Project documents describe the design intent ofthe work and are not a representation of as-builtor existing conditions. LPA is not responsible forany discrepancies between the project documentsand the existing conditions.© LPA, Inc.SCHEMATIC DESIGN 10/27/2022 50% DESIGN DEVELOPMENT 12/02/2022
100% DESIGN DEVELOPMENT 01/06/2023
30% CONSTRUCTION DOCS 02/10/2023 COLUMBIA WAY
DOWNEY, CA 90242
CITY OF DOWNEY
SPACE SHUTTLE EXHIBIT AND EDUCATION
BUILDING 26429 Rancho Parkway South #145, Lake Forest, CA 92630Phone: 949.309.2820 Fax: 949.613.5905 www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPFM3.04EXTERIORELEVATIONSScale: 1/8" = 1'-0"STEM BUILDING - EXTERIOR ELEVATION - EAST02Scale: 1/8" = 1'-0"STEM BUILDING - EXTERIOR ELEVATION - SOUTH18Scale: 1/8" = 1'-0"STEM BUILDING - EXTERIOR ELEVATION - NORTH10Scale: 1/8" = 1'-0"STEM BUILDING - EXTERIOR ELEVATION - WEST16
01 - FLOOR0'-0"02 - FLOOR15'-0"TOP OF STRUCTURE54'-0"ROOF58'-0"LOW ROOF20'-6"1FM9.02GROUND OPERATIONSHORIZONTAL LIFE LINE2FM9.011250# WORKING LOAD (OSHA)5000# FACTORED LOAD (OSHA)3100# LIVE LOAD (CBC)ANY DIRECTION48' MAX.WFP TYP. ZONEGOOSENECK ATTACHED TOWATERFED POLEGLASS ABOVE HANGAR DOORHEADER MIGHT REQUIRE THE USE OFA BOOM LIFT FOR PROPER ACCESS.Y:\CLIENTS\LPA\Space Shuttle Exhibit\Space Shuttle Exhibit - OFAC\NC-24-028 DD R2.1 100%.dwg 7/31/2025 7:32:23 AMTHIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF OLYMPIQUE FACADE ACCESS CONSULTING. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION OR DISCLOSURE OF THE DRAWING, DOCUMENTS AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF OLYMPIQUE FACADE ACCESS CONSULTING.NOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTIONDeveloped forJob NumberDate PublishedChecked ByScaleRevision Date ARCHITECTURE ENGINEERING INTERIORSLANDSCAPE ARCHITECTURE PLANNING949-261-1001 Office949-260-1190 FaxLPADesignStudios.com5301 California Avenue,Suite 100Irvine, California 92617Submittal Date This document and all other project documents,ideas, aesthetics and designs incorporatedtherein are instruments of service. All projectdocuments are copyright protected, are theproperty of LPA, Inc. (LPA) and cannot be lawfullyused in whole or in part for any project or purposeexcept as set forth in the contractual agreementbetween LPA and its Client. The unauthorizeddisclosure and/or use of the project documents(including the creation of derivative works), maygive rise to liability for copyright infringement,unlawful disclosure, use or misappropriation ofproperty rights held by LPA. The unauthorizeduse of the project documents will give rise to therecovery of monetary losses and damagesincluding attorney fees and costs for which theunauthorized user will be held liable.Project documents describe the design intent ofthe work and are not a representation of as-builtor existing conditions. LPA is not responsible forany discrepancies between the project documentsand the existing conditions.© LPA, Inc.SCHEMATIC DESIGN 10/27/2022 50% DESIGN DEVELOPMENT 12/02/2022
100% DESIGN DEVELOPMENT 01/06/2023
30% CONSTRUCTION DOCS 02/10/2023 COLUMBIA WAY
DOWNEY, CA 90242
CITY OF DOWNEY
SPACE SHUTTLE EXHIBIT AND EDUCATION
BUILDING 26429 Rancho Parkway South #145, Lake Forest, CA 92630Phone: 949.309.2820 Fax: 949.613.5905 www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPFM3.21WALL SECTIONSScale: 1/4" = 1'-0"WALL SECTION01
01 - FLOOR0'-0"02 - FLOOR15'-0"AFDECBD.92FM9.01HORIZONTAL LIFELINE48' MAX.WFP TYP. ZONE1FM9.01ROOF HATCH01 - FLOOR02 - FLOORBBEEFFAACCDD1FM9.02GROUND OPERATIONS2FM9.01HORIZONTAL LIFELINE48' MAX.WFP TYP. ZONEGLASS ABOVE HANGAR DOOR HEADER MIGHT REQUIRETHE USE OF A BOOM LIFT FOR PROPER ACCESS.LEGENDWINDOWS TO BE ACCESSED FROM EXTERIORBY GROUND OPERATIONS (HIGH-REACH POLE;ASSUMING NO POWER LINES WITHIN RANGEOF MOTION), SEE DETAIL 1/FM9.02Y:\CLIENTS\LPA\Space Shuttle Exhibit\Space Shuttle Exhibit - OFAC\NC-24-028 DD R2.1 100%.dwg 7/31/2025 7:32:28 AMTHIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF OLYMPIQUE FACADE ACCESS CONSULTING. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION OR DISCLOSURE OF THE DRAWING, DOCUMENTS AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF OLYMPIQUE FACADE ACCESS CONSULTING.NOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTIONDeveloped forJob NumberDate PublishedChecked ByScaleRevision Date ARCHITECTURE ENGINEERING INTERIORSLANDSCAPE ARCHITECTURE PLANNING949-261-1001 Office949-260-1190 FaxLPADesignStudios.com5301 California Avenue,Suite 100Irvine, California 92617Submittal Date This document and all other project documents,ideas, aesthetics and designs incorporatedtherein are instruments of service. All projectdocuments are copyright protected, are theproperty of LPA, Inc. (LPA) and cannot be lawfullyused in whole or in part for any project or purposeexcept as set forth in the contractual agreementbetween LPA and its Client. The unauthorizeddisclosure and/or use of the project documents(including the creation of derivative works), maygive rise to liability for copyright infringement,unlawful disclosure, use or misappropriation ofproperty rights held by LPA. The unauthorizeduse of the project documents will give rise to therecovery of monetary losses and damagesincluding attorney fees and costs for which theunauthorized user will be held liable.Project documents describe the design intent ofthe work and are not a representation of as-builtor existing conditions. LPA is not responsible forany discrepancies between the project documentsand the existing conditions.© LPA, Inc.SCHEMATIC DESIGN 10/27/2022 50% DESIGN DEVELOPMENT 12/02/2022
100% DESIGN DEVELOPMENT 01/06/2023
30% CONSTRUCTION DOCS 02/10/2023 COLUMBIA WAY
DOWNEY, CA 90242
CITY OF DOWNEY
SPACE SHUTTLE EXHIBIT AND EDUCATION
BUILDING 26429 Rancho Parkway South #145, Lake Forest, CA 92630Phone: 949.309.2820 Fax: 949.613.5905 www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPFM5.03INTERIORELEVATIONSScale: 1/8" = 1'-0"STEM BUILDING - INTERIOR ELEVATION - EAST01Scale: 1/8" = 1'-0"STEM BUILDING - INTERIOR ELEVATION - LOOKING NORTHWEST02
LEGENDWINDOWS TO BE ACCESSED FROM EXTERIORBY GROUND OPERATIONS (HIGH-REACH POLE;ASSUMING NO POWER LINES WITHIN RANGEOF MOTION), SEE DETAIL 1/FM9.0201 - FLOOR0'-0"02 - FLOOR15'-0"1234567894.24.81.15.25.836'-0"2FM9.01HORIZONTAL LIFE LINEWFP TYP. ZONE01 - FLOOR0'-0"02 - FLOOR15'-0"234567894.24.85.25.82FM9.01HORIZONTAL LIFE LINE1FM9.02GROUND OPERATIONS1FM9.01ROOF HATCHY:\CLIENTS\LPA\Space Shuttle Exhibit\Space Shuttle Exhibit - OFAC\NC-24-028 DD R2.1 100%.dwg 7/31/2025 7:32:33 AMTHIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF OLYMPIQUE FACADE ACCESS CONSULTING. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION OR DISCLOSURE OF THE DRAWING, DOCUMENTS AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF OLYMPIQUE FACADE ACCESS CONSULTING.NOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTIONDeveloped forJob NumberDate PublishedChecked ByScaleRevision Date ARCHITECTURE ENGINEERING INTERIORSLANDSCAPE ARCHITECTURE PLANNING949-261-1001 Office949-260-1190 FaxLPADesignStudios.com5301 California Avenue,Suite 100Irvine, California 92617Submittal Date This document and all other project documents,ideas, aesthetics and designs incorporatedtherein are instruments of service. All projectdocuments are copyright protected, are theproperty of LPA, Inc. (LPA) and cannot be lawfullyused in whole or in part for any project or purposeexcept as set forth in the contractual agreementbetween LPA and its Client. The unauthorizeddisclosure and/or use of the project documents(including the creation of derivative works), maygive rise to liability for copyright infringement,unlawful disclosure, use or misappropriation ofproperty rights held by LPA. The unauthorizeduse of the project documents will give rise to therecovery of monetary losses and damagesincluding attorney fees and costs for which theunauthorized user will be held liable.Project documents describe the design intent ofthe work and are not a representation of as-builtor existing conditions. LPA is not responsible forany discrepancies between the project documentsand the existing conditions.© LPA, Inc.SCHEMATIC DESIGN 10/27/2022 50% DESIGN DEVELOPMENT 12/02/2022
100% DESIGN DEVELOPMENT 01/06/2023
30% CONSTRUCTION DOCS 02/10/2023 COLUMBIA WAY
DOWNEY, CA 90242
CITY OF DOWNEY
SPACE SHUTTLE EXHIBIT AND EDUCATION
BUILDING 26429 Rancho Parkway South #145, Lake Forest, CA 92630Phone: 949.309.2820 Fax: 949.613.5905 www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPFM5.04INTERIORELEVATIONSScale: 1/8" = 1'-0"STEM BUILDING - INTERIOR ELEVATION - SOUTH01Scale: 1/8" = 1'-0"STEM BUILDING - INTERIOR ELEVATION - NORTH02
42"ABOVE THE ROOFSURFACE OR DECKALUMINUM POST HINGESTAINLESS STEEL TORSION RODSELF CLOSING (FRP) GATE (Ø1.91)ALUMINUM GATE HINGESTEEL CORNER BRACKETS(HOT DIP GALVANIZED)ALUMINUM POST SUPPORTSFIBERGLASS REINFORCED POLYMER (FRP),YELLOW, UV RESISTANT & FIRE RETARDANT (Ø1.91)12' MAX.TENSIONEREND ANCHOR, BYCONTRACTOR TYP.MAX. HEIGHT PER STRUCTURAL NOTE:1. NO CONCURRENT LOADING ALLOWED (HLL AND SECONDARY ANCHOR)2. TIEBACK ANCHOR LOOPHOLES MOUNTED ON HLL POSTS WILL NEED TOFACE TOWARDS THE EDGE OF THE ROOFSECOND ANCHOR POINT, TYP.7"Ø MIN. HSS WITH1/2" MIN. WALL1250# WORKING LOAD (OSHA)5000# FACTORED LOAD (OSHA)3100# LIVE LOAD (CBC)ANY DIRECTION1250# WORKING LOAD (OSHA)5000# FACTORED LOAD (OSHA)3100# LIVE LOAD (CBC)ANY DIRECTIONINSULATED METALPANELWELD BASE PLATE TO CENTER OFSTRUCTURAL STEEL BEAM ORPROVIDE WELD PLATE WITHSTRUCTURAL FRAMING8" MIN.FLASHINGSTEEL BEAM, REFER TO STRUCTURAL.ENGINEER OF RECORD TO VERIFY WHETHERGUSSET PLATES OR CROSS BEAMS AREREQUIRED TO SUPPORT ANCHOR DESIGNLOADS.T.O. STEEL BEAMT.O. ROOF1250# WORKING LOAD (OSHA)5000# FACTORED LOAD (OSHA)3100# LIVE LOAD (CBC)ANY DIRECTIONVARIES TENSIONERCORNER ANCHORTOP VIEWU-BAR ATTACHEDAT CORNER PERPLAN1250# WORKING LOAD (OSHA)5000# FACTORED LOAD (OSHA)3100# LIVE LOAD (CBC)ANY DIRECTION8" MIN.FLASHINGINSULATED METALPANELMAX. HEIGHT PER STRUCTURALWELD BASE PLATE TO CENTER OFSTRUCTURAL STEEL BEAM ORPROVIDE WELD PLATE WITHSTRUCTURAL FRAMINGSTEEL BEAM, REFER TO STRUCTURAL.ENGINEER OF RECORD TO VERIFY WHETHERGUSSET PLATES OR CROSS BEAMS AREREQUIRED TO SUPPORT ANCHOR DESIGNLOADS.STEEL BASE PLATER350# WORKING LOAD900# FALL ARREST LOAD WITH shock absorbing lanyard1250# FALL ARREST LOAD WITHOUT shock absorbing lanyardWITHOUT shock absorbing lanyardR = (1250#)(2)(cos q/2)WITH 900# shock absorbing lanyardR = (900#)(2)(cos q/2)q/2q/2qHLL SYSTEMFACE OF WALL1250# WORKING LOAD (OSHA)5000# FACTORED LOAD (OSHA)3100# LIVE LOAD (CBC)ANY DIRECTION2--SECONDARY ANCHORFOR SAFETY LINENOTE:1. NO CONCURRENT LOADING ALLOWED (HLL AND SECONDARY ANCHOR)2. TIEBACK ANCHOR LOOPHOLES MOUNTED ON HLL POSTS WILL NEED TOFACE TOWARDS THE EDGE OF THE ROOFY:\CLIENTS\LPA\Space Shuttle Exhibit\Space Shuttle Exhibit - OFAC\NC-24-028 DD R2.1 100%.dwg 7/31/2025 7:32:38 AMTHIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF OLYMPIQUE FACADE ACCESS CONSULTING. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION OR DISCLOSURE OF THE DRAWING, DOCUMENTS AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF OLYMPIQUE FACADE ACCESS CONSULTING.NOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTIONDeveloped forJob NumberDate PublishedChecked ByScaleRevision Date ARCHITECTURE ENGINEERING INTERIORSLANDSCAPE ARCHITECTURE PLANNING949-261-1001 Office949-260-1190 FaxLPADesignStudios.com5301 California Avenue,Suite 100Irvine, California 92617Submittal Date This document and all other project documents,ideas, aesthetics and designs incorporatedtherein are instruments of service. All projectdocuments are copyright protected, are theproperty of LPA, Inc. (LPA) and cannot be lawfullyused in whole or in part for any project or purposeexcept as set forth in the contractual agreementbetween LPA and its Client. The unauthorizeddisclosure and/or use of the project documents(including the creation of derivative works), maygive rise to liability for copyright infringement,unlawful disclosure, use or misappropriation ofproperty rights held by LPA. The unauthorizeduse of the project documents will give rise to therecovery of monetary losses and damagesincluding attorney fees and costs for which theunauthorized user will be held liable.Project documents describe the design intent ofthe work and are not a representation of as-builtor existing conditions. LPA is not responsible forany discrepancies between the project documentsand the existing conditions.© LPA, Inc.SCHEMATIC DESIGN 10/27/2022 50% DESIGN DEVELOPMENT 12/02/2022
100% DESIGN DEVELOPMENT 01/06/2023
30% CONSTRUCTION DOCS 02/10/2023 COLUMBIA WAY
DOWNEY, CA 90242
CITY OF DOWNEY
SPACE SHUTTLE EXHIBIT AND EDUCATION
BUILDING 26429 Rancho Parkway South #145, Lake Forest, CA 92630Phone: 949.309.2820 Fax: 949.613.5905 www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPFM9.01DETAILSScale: 1 1/2" = 1'-0"FALL PREVENTION AT ROOF HATCH1Scale: 1 1/2" = 1'-0"HORIZONTAL LIFELINE (HLL)2Scale: 1" = 1'-0"LOADING DETAIL3
TOP VIEWSIDE SECTIONH x .25H (48' MAX.)TOP OF SLABCENTERLINE OF WINDOW ±18"WATERFED POLE WORKING CLEARANCE ZONEEDGE OF ROOF OVER HANG(WHERE OCCURS)WALL BELOW (WHERE OCCURS)WINDOW BELOWH = HEIGHT FROM GRADE TO TOP OF WINDOW HEADOF TOP FLOOR WINDOW.h = HEIGHT FROM GRADE TO TOP OF WINDOW HEADOF 2ND LEVEL WINDOW.H = MAXIMUM HEIGHT OF TOP FLOOR WINDOW HEADUSING WATER FED EXTENSION POLE WHEN WORKINGAT GRADE3'h x .25TOP OF WINDOWAT LEVEL 4TOP OF WINDOWAT LEVEL 3TOP OF WINDOWAT LEVEL 2TOP OF WINDOWAT LEVEL 1h TOP OF WINDOWAT LEVEL 5WIDTH OF WINDOW 30" SQ. PAVER INLANDSCAPE WHEREPLANTERS OCCUR OVERPODIUM. ALL OTHER RAISEDAREAS TO BE LEVEL ANDFREE OF OBSTRUCTIONSWITHIN WORKING ZONE.INCLUDING PLANTMATERIALS, TREES ANDFUTURE GROWTH.SITE AND/OR GRADEREQUIREMENTS FOR GROUNDOPERATIONS SHOWN.INTERIOR SIDEOF PARAPET (ROOF)T.O. FINISHED ROOF18" MAX.T.O. FINISHED ROOFT.O. FINISHED ROOFGUARDRAIL18" MAX.6" MAX.AT LEAST ONE (1) OF THESE CONDITIONS MUST BE SATISFIED ATALL GUARDRAIL LOCATIONS. REFER TO KEYNOTES ON PLANS FORADDITIONAL REQUIREMENTS, RESTRICTIONS AND/OR LIMITATIONS.ROOF CURB/LOWPARAPETEXTENDED SLABROOF CURB / LOWPARAPET42" MIN - 45" MAX GUARDRAIL OR 42" MIN - 72" MAX PARAPETWIDE CURB / PARAPET42" MIN - 45" MAX GUARDRAIL OR42" MIN - 72" MAX PARAPET PARAPET WIDTH >18"GUARDRAILCEXTENDED SLAB EDGEWITH CURB CONDITIONBWIDE CURB /PARAPET CONDITIONGUARDRAIL18" MAX.6"MAX.42" MIN - 45" MAX GUARDRAIL OR42" MIN - 72" MAX PARAPETASETBACK GUARDRAILCONDITIONEXTERIOR SIDEOF PARAPETEXTERIOR SIDEOF PARAPETINTERIOR SIDEOF PARAPET (ROOF)EXTERIOR SIDEOF PARAPETY:\CLIENTS\LPA\Space Shuttle Exhibit\Space Shuttle Exhibit - OFAC\NC-24-028 DD R2.1 100%.dwg 7/31/2025 7:32:43 AMTHIS DRAWING, ANY RELATED DOCUMENTS AND RELATED INFORMATION ARE THE PROPERTY OF OLYMPIQUE FACADE ACCESS CONSULTING. THEY MAY ONLY BE USED FOR THE SPECIFIC PURPOSE FOR WHICH THEY HAVE BEEN PROVIDED. NO REPRODUCTION, DUPLICATION OR DISCLOSURE OF THE DRAWING, DOCUMENTS AND INFORMATION IS PERMITTED WITHOUT THE PRIOR WRITTEN CONSENT OF OLYMPIQUE FACADE ACCESS CONSULTING.NOT FOR REGULATORY APPROVAL,PERMITTING OR CONSTRUCTIONDeveloped forJob NumberDate PublishedChecked ByScaleRevision Date ARCHITECTURE ENGINEERING INTERIORSLANDSCAPE ARCHITECTURE PLANNING949-261-1001 Office949-260-1190 FaxLPADesignStudios.com5301 California Avenue,Suite 100Irvine, California 92617Submittal Date This document and all other project documents,ideas, aesthetics and designs incorporatedtherein are instruments of service. All projectdocuments are copyright protected, are theproperty of LPA, Inc. (LPA) and cannot be lawfullyused in whole or in part for any project or purposeexcept as set forth in the contractual agreementbetween LPA and its Client. The unauthorizeddisclosure and/or use of the project documents(including the creation of derivative works), maygive rise to liability for copyright infringement,unlawful disclosure, use or misappropriation ofproperty rights held by LPA. The unauthorizeduse of the project documents will give rise to therecovery of monetary losses and damagesincluding attorney fees and costs for which theunauthorized user will be held liable.Project documents describe the design intent ofthe work and are not a representation of as-builtor existing conditions. LPA is not responsible forany discrepancies between the project documentsand the existing conditions.© LPA, Inc.SCHEMATIC DESIGN 10/27/2022 50% DESIGN DEVELOPMENT 12/02/2022
100% DESIGN DEVELOPMENT 01/06/2023
30% CONSTRUCTION DOCS 02/10/2023 COLUMBIA WAY
DOWNEY, CA 90242
CITY OF DOWNEY
SPACE SHUTTLE EXHIBIT AND EDUCATION
BUILDING 26429 Rancho Parkway South #145, Lake Forest, CA 92630Phone: 949.309.2820 Fax: 949.613.5905 www.facadeaccess.comOFAC Project No.: NC-24-024R2.1 07.31.25100% FMDDPM:DPFM9.02DETAILSScale: 3/8" = 1'-0"GROUND OPERATIONS FOR WINDOW CLEANING REQUIREMENTS WITH WATERFED EXTENSION POLE1Scale: 3/4" = 1'-0"GUARDRAIL LOCATION REQUIREMENTS2