Utility Master Plan Page 681 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 16-Chemicals WTM-Field Instruments-276
Instrumentation and
Controls 2010 LSH-960A
LSH-960A, FLOOD SWITCH, NORTH CHEMICAL SPILL TRENCH,
CHEM BLDG, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2
Replace or Run to
Failure
Process/Facility Operates Normally
Without 2 2 14 Low
WTM 16-Chemicals WTM-Field Instruments-277
Instrumentation and
Controls 2010 LSH-960B
LSH-960B, HIGH LEVEL FLOOD SWITCH, SOUTH CHEMICAL SPILL TRENCH, CHEM BLDG, WTP Field Instruments Level Element 2 Replace or Run to
Failure
Process/Facility Operates Normally
Without 2 2 14 Low
WTM 16-Chemicals WTM-Field Instruments-278
Instrumentation and
Controls 2010 LSL-197
LSL 797, LOW LEVEL SWITCH, ACID SPILL SUMP, CHEMICAL SPILL CONTAINMENT, WTP Field Instruments Level Element 2
Replace or Run to
Failure
Process/Facility Operates Normally
Without 2 2 14 Low
WTM 17-Ozone Generation WTM-Field Instruments-279
Instrumentation and
Controls 2010 1-ME-5
OzGen Ozone Concentration Analyzer, EAST WALL, OZONE
GENERATOR ROOM, Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 12-Pretreatment WTM-Field Instruments-28
Instrumentation and
Controls 2010 AE-537 TURBIDITY, ACTIFLO EAST TRAIN Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-280
Instrumentation and
Controls 2010 1-ME-6 OzGen Ambient Ozone Analyzer, OZONE GENERATOR ROOM, Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 2 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 17-Ozone Generation WTM-Field Instruments-281
Instrumentation and
Controls 1990 1-ME-7

OXYGEN DEW POINT ANALYZER, OZONE GENERATOR ROOM,
WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) -18 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-282
Instrumentation and
Controls 2010 OG-NBMET-1
OG-NBMET-1, FLOW METER, NITROGEN BOOST SKID, OZONE
GEN RM, WTP Field Instruments Flow 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 17-Ozone Generation WTM-Field Instruments-283
Instrumentation and
Controls 2010 OG-NBSW-1
OG-NBSW-1, THERMAL SWITCH, NITROGEN BOOST DISCHARGE,
NITROGEN SKID, OZONE GEN RM, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 17-Ozone Generation WTM-Field Instruments-284
Instrumentation and
Controls 2010 OG-NBSW-2
OG-NBSW-2, WEST PRESSURE SWITCH, AIR RECEIVER,
NITROGEN BOOST SKID, OZONE GEN RM, WTP Field Instruments Pressure 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-285
Instrumentation and
Controls 2010 OG-NBSW-3
OG-NBSW-3, EAST PRESSURE SWITCH, AIR RECEIVER, NITROGEN BOOST SKID, OZONE GEN RM, WTP Field Instruments Pressure 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-286
Instrumentation and
Controls 1990 AE/AIT-249
AE/AIT-249, ANALYZER, OZONE GAS CONCENTRATION, OZONE
GENERATORS, OZONE GENERATOR ROOM, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) -18 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-287
Instrumentation and
Controls 1990 FE-192
FE-192, FLOW METER, OZONE GENERATOR 1 COOLING WATER,
OZONE GENERATOR ROOM, WTP Field Instruments Flow -18 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-288
Instrumentation and
Controls 1990 FE-242
FE-242, FLOW METER, OZONE GENERATOR 2 COOLING WATER,
OZONE GENERATOR ROOM, WTP Field Instruments Flow -18 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-289
Instrumentation and
Controls 2010 FE-892
FE-892, FLOW METER, OZONE GENERATOR 3 COOLING WATER,
OZONE GENERATOR ROOM, WTP Field Instruments Flow 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 12-Pretreatment WTM-Field Instruments-29
Instrumentation and
Controls 2010 AE-557 AE-557, TURBIDITY ANALYZER, WEST ACTIFLO, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-290
Instrumentation and
Controls 1990 FIT-192
FIT-192, TRANSMITTER, OZONE GENERATOR 1 COOLING WATER
FLOW METER, OZONE GENERATOR ROOM, WTP Field Instruments Flow -18 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-291
Instrumentation and
Controls 1990 FIT-242
FIT-242, TRANSMITTER, OZONE GENERATOR 2 COOLING WATER
FLOW METER, OZONE GENERATOR ROOM, WTP Field Instruments Flow -18 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-292
Instrumentation and
Controls 2010 FIT-246

OZONE FLOW TRANSMITTER, OZONE GAS TO CONTACTORS,
OZONE GENERATOR ROOM, WTP Field Instruments Flow 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-293
Instrumentation and
Controls 2010 FIT-892
FIT-892, TRANSMITTER, OZONE GENERATOR 3 COOLING WATER
FLOW METER, OZONE GENERATOR ROOM, WTP Field Instruments Flow 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 17-Ozone Generation WTM-Field Instruments-294
Instrumentation and
Controls 1990 PIT-152 PRESSURE TRANSMITTER, LOX STORAGE TANK, LOX AREA, WTP Field Instruments Pressure -18 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 17-Ozone Generation WTM-Field Instruments-295
Instrumentation and
Controls 1990 LIT-152
LIT-152, LEVEL TRANSMITTER, LOX STORAGE TANK, LOX AREA, WTP Field Instruments Level Element -18
Replace or Run to
Failure
Process/Facility Operates Normally
Without 2 2 14 Low
WTM 17-Ozone Generation WTM-Field Instruments-296
Instrumentation and
Controls 2010 PIT-247

OZONE PRESSURE TRANSMITTER, OZONE GAS TO CONTACTORS,
OZONE GENERATOR ROOM, WTP Field Instruments Pressure 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 17-Ozone Generation WTM-Field Instruments-297
Instrumentation and
Controls 2010 PIT-LCP-OCCP

PIT-LCP-OCCP, PRESSURE TRANSMITTER, OZONE FEED GAS,
OZONE GENERATOR ROOM, WTP Field Instruments Pressure 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 17-Ozone Generation WTM-Field Instruments-298
Instrumentation and
Controls 2010 PSL-868
PSL-868, PRESSURE SWITCH, LOW FLOW, OZONE GENERATOR 3
COOLING WATER INFLUENT, OZONE GENERATOR ROOM, WTP Field Instruments Pressure 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 17-Ozone Generation WTM-Field Instruments-299
Instrumentation and
Controls 2010 TIT-LCP-OCCP

TEMPERATURE TRANSMITTER, ROSEMOUNT, OZONE FEED GAS,
OZONE GENERATOR ROOM, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 11-Intake / LLPS WTM-Field Instruments-3
Instrumentation and
Controls 2010 PSH-514
PSH 514, PUMP 4 DISCHARGE HIGH PRESSURE SWITCH, LLPS,
WTP Field Instruments Pressure 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 12-Pretreatment WTM-Field Instruments-30
Instrumentation and
Controls 2010 FSL-555
LOW FLOW SWITCH, WEST ACTIFLO SAMPLE PUMP, AF-PMP-24,
WTP Field Instruments Flow 2 Rehabilitation
Process/Facility Operates Normally
Without 2 2 12 Low
WTM 18-EQ Basin + WW PS WTM-Field Instruments-300
Instrumentation and
Controls 2010 AE/AIT-729A EQ BASIN DECANT TURB, RPS, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 2
Replace or Run to
Failure Reduced Efficiency 2 4 28 Med-Low
WTM 18-EQ Basin + WW PS WTM-Field Instruments-301
Instrumentation and
Controls 2010 LIT-727 EQ BASIN 1, Level Transmitter, Field Instruments Level Element 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 18-EQ Basin + WW PS WTM-Field Instruments-302
Instrumentation and
Controls 2010 LIT-728 EQ BASIN 2 Level Transmitter, Field Instruments Level Element 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Field Instruments-303 Instrumentation and
Controls 2010 AE-729B CLARIFIER INF (SLUDGE) Turb, RPS, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Field Instruments-304 Instrumentation and
Controls 2010 AIT-729B
AIT-729B, TRANSMITTER, TURBIDITY, CLARIFIER INF (SLUDGE), WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Field Instruments-305 Instrumentation and
Controls 2010 AIT-729C AIT-729C, TRANSMITTER, TURBIDITY, RETURN to LL Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 19-Sludge Clarifiers and Lagoons WTM-Field Instruments-306 Instrumentation and
Controls 2010 LE-753A CLARIFIER #1 LEVEL DETECTOR, Field Instruments Level Element 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Field Instruments-307 Instrumentation and
Controls 2010 LE-753B CLARIFIER #2 LEVEL DETECTOR, Field Instruments Level Element 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Field Instruments-308 Instrumentation and
Controls 2010 LIT-SL-1 FLOW/LEVEL TRANSMITTER EFFLENT SLUICE GATE, LAGOON 1 Field Instruments Level Element 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Field Instruments-309 Instrumentation and
Controls 2010 LIT-SL-2 FLOW/LEVEL TRANSMITTER EFFLENT SLUICE GATE, LAGOON 2 Field Instruments Level Element 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 12-Pretreatment WTM-Field Instruments-31
Instrumentation and
Controls 2010 AF-PSH-542 HI WATER PSI SWITCH, SAND EDUCTOR, WTP Field Instruments Level Element 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Field Instruments-310 Instrumentation and
Controls 2010 LIT-SL-3 FLOW/LEVEL TRANSMITTER EFFLENT SLUICE GATE, LAGOON 3 Field Instruments Level Element 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low

Page 10 of 24 ends

Clity of Fairfield
Utility Master Plan Page 682 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 21-Blowers / Z3PS WTM-Field Instruments-311
Instrumentation and
Controls 2010 FIT-UW1 Z3 Utility Mag Meter, ZONE 3 PS, WTP Field Instruments Flow 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 21-Blowers / Z3PS WTM-Field Instruments-312
Instrumentation and
Controls 2010 Meter-5
UW-CONVERTER-1, SIGNAL CONVERTER, ZONE 3 UTILITY WATER
MAG METER, ZONE 3 PS, WTP Field Instruments Flow 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 00-Misc Systems WTM-Field Instruments-314
Instrumentation and
Controls 2010 FIT-734 RECYCLE FLOWMETER, Field Instruments Flow 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 00-Misc Systems WTM-Field Instruments-315
Instrumentation and
Controls 2010 FIT-930
FIT-930, FLOW METER, ACH, FLASH MIX 1 ADDITION, CHEM
BLDG, WTP Field Instruments Flow 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 00-Misc Systems WTM-Field Instruments-316
Instrumentation and
Controls 2010 FIT-526A

WTP INF MAG FLOW METER, PLANT INFLUENT WTP, METER
VAULT, WTP Field Instruments Flow 2 Rehabilitation Process/Facility Cannot Operate Without 2 6 36 Med-High WTM 00-Misc Systems WTM-Field Instruments-317
Instrumentation and
Controls 2010 FIT-526B PLANT INF FLOW METER TRANSIT TIME, Field Instruments Flow 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 12-Pretreatment WTM-Field Instruments-32
Instrumentation and
Controls 2010 AF-PSL-542 LOW WATER PSI SWITCH, SAND EDUCTOR, WTP Field Instruments Level Element 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 12-Pretreatment WTM-Field Instruments-33
Instrumentation and
Controls 2010 AIT-525A
AIT-525A, TRANSMITTER, TURBIDITY, PLANT INFLUENT, FLASH MIX, OPS BASEMENT, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 12-Pretreatment WTM-Field Instruments-34
Instrumentation and
Controls 2010 AIT-536 AIT-536, TRANSMITTER, PH/TEMP, ACTIFLO EAST TRAIN, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 12-Pretreatment WTM-Field Instruments-35
Instrumentation and
Controls 2010 AIT-556 AIT 556, TRANSMITTER, PH/TEMP, WEST TRAIN, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 12-Pretreatment WTM-Field Instruments-36
Instrumentation and
Controls 2010 AIT-557 AIT 557, TRANSMITTER, TURBIDIMETER, WEST TRAIN, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 12-Pretreatment WTM-Field Instruments-37
Instrumentation and
Controls 2010 FSL-535 LOW FLOW SWITCH, EAST ACTIFLO SAMPLE PUMP, WTP Field Instruments Flow 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 12-Pretreatment WTM-Field Instruments-38
Instrumentation and
Controls 2010 PSL-538 LOW PSI SWITCH, EAST ACTIFLO SAND PUMP 1, AF-PMP-11, WTP Field Instruments Pressure 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 12-Pretreatment WTM-Field Instruments-39
Instrumentation and
Controls 2010 PSL-539 LOW PSI SWITCH, EAST ACTIFLO SAND PUMP 2, AF-PMP-12, WTP Field Instruments Pressure 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 11-Intake / LLPS WTM-Field Instruments-4
Instrumentation and
Controls 2010 PSH-513
PSH-513, HIGH PRESSURE SWITCH, PUMP 3 DISCHARGE, LLPS,
WTP Field Instruments Pressure 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 12-Pretreatment WTM-Field Instruments-40
Instrumentation and
Controls 2010 PSL-540 LOW PSI SWITCH, EAST ACTIFLO SAND PUMP 3, AF-PMP-13, WTP Field Instruments Pressure 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 12-Pretreatment WTM-Field Instruments-41
Instrumentation and
Controls 2010 PSL-558 PSL-558, LOW PSI SWITCH, SAND PUMP 1, WEST ACTIFLO, WTP Field Instruments Pressure 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 12-Pretreatment WTM-Field Instruments-42
Instrumentation and
Controls 2010 PSL-559 PSL-559, LOW PSI SWITCH, SAND PUMP 2, WEST ACTIFLO, WTP Field Instruments Pressure 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 12-Pretreatment WTM-Field Instruments-43
Instrumentation and
Controls 2010 PSL-560 PSL-560, LOW PSI SWITCH, SAND PUMP 3, WEST ACTIFLO, WTP Field Instruments Pressure 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-44
Instrumentation and
Controls 2006 Instrument-216 GAUGE, DIFFERENTIAL PRESSURE DEMISTER, OZONE BASIN 1 Field Instruments Pressure -2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-45
Instrumentation and
Controls 2006 Instrument-217
GAUGE, COMPOUND PRESSURE, DEMISTER, OZONE BASIN 1
EAST TRAIN Field Instruments Pressure -2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-46
Instrumentation and
Controls 2006 Instrument-218
GAUGE, COMPOUND PRESSURE, DEMISTER, OZONE BASIN 1
WEST TRAIN Field Instruments Pressure -2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-47
Instrumentation and
Controls 2010 FI 121
FI 121, OZONE ROTOMETER 4A, GT 1600, 2.4-24 SCFM, OZONE DESTRUCT ROOM, WTP Field Instruments Flow 2 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-48
Instrumentation and
Controls 2010 FI 122
FI 122, OZONE ROTOMETER 3B, GT 1600, 2.4-24 SCFM, OZONE DESTRUCT ROOM, WTP Field Instruments Flow 2 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-49
Instrumentation and
Controls 2010 FI 125
FI 125, OZONE ROTOMETER 4B, GT 1600, 2.4-24 SCFM, OZONE DESTRUCT ROOM, WTP Field Instruments Flow 2 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 11-Intake / LLPS WTM-Field Instruments-5
Instrumentation and
Controls 2010 CNL-PMP-2 CNL-PMP-2, High Pressure Sample pump to Canal Shack, WTP Field Instruments Pressure 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-50
Instrumentation and
Controls 2010 FI 126
FI 126, OZONE ROTOMETER 3A, GT 1600, 2.4-24 SCFM, OZONE DESTRUCT ROOM, WTP Field Instruments Flow 2 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-51
Instrumentation and
Controls 2010 FI 571A
FI 571A, OZONE ROTOMETER 1A, GT 1600, 2.4-24 SCFM, OZONE DESTRUCT ROOM, WTP Field Instruments Flow 2 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-52
Instrumentation and
Controls 2010 FI 571B
FI 571B, OZONE ROTOMETER 1B, GT 1600, 2.4-24 SCFM, OZONE DESTRUCT ROOM, WTP Field Instruments Flow 2 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-53
Instrumentation and
Controls 2010 FI 571C
FI 571C, OZONE ROTOMETER 2B, GT 1600, 2.4-24 SCFM, OZONE DESTRUCT ROOM, WTP Field Instruments Flow 2 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-54
Instrumentation and
Controls 2010 FI 571D
FI 571D, OZONE ROTOMETER 2A, GT 1600, 2.4-24 SCFM, OZONE DESTRUCT ROOM, WTP Field Instruments Flow 2 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-55
Instrumentation and
Controls 2010 Instrument-214 VACUUM TRANSMITTER, OZONE BASIN 2 Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-56
Instrumentation and
Controls 2010 Instrument-215 GAUGE, DIFFERENTIAL PRESSURE, OZONE BASIN 1, EAST TRAIN Field Instruments Pressure 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-57
Instrumentation and
Controls 2010 PI-574A
GAUGE, DIFFERENTIAL PRESSURE DEMISTER, OZONE BASIN 1,
OZONE CONTACTOR, WTP Field Instruments Pressure 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-58
Instrumentation and
Controls 2010 PI-574B
GAUGE, COMPOUND PRESSURE, DEMISTER, OZONE BASIN 1
WEST TRAIN, OZONE CONTACTOR, WTP Field Instruments Pressure 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-59
Instrumentation and
Controls 2010 PIT-107
VACUUM TRANSMITTER, OZONE BASIN 3, OZONE CONTACTOR,
WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 11-Intake / LLPS WTM-Field Instruments-6
Instrumentation and
Controls 2016 CNL-AE-104
CNL-AE-104, CANAL CONDUCTIVITY SENSOR, CANAL SHACK,
WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 8 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-60
Instrumentation and
Controls 2010 PIT-108
VACUUM TRANSMITTER, OZONE BASIN 4, OZONE CONTACTOR,
WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-61
Instrumentation and
Controls 2010 PIT-574B
PIT-574B, VACUUM TRANSMITTER, OZONE BASIN 1, OZONE
CONTACTOR, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-62
Instrumentation and
Controls 2010 PSV-131
PSV-131, GAUGE, COMPOUND PRESSURE/VACUUM, DEMISTER,
OZONE BASIN 1 EAST TRAIN, OZONE CONTACTOR, WTP Field Instruments Pressure 2 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low

Page 11 of 24 ends

Clity of Fairfield
Utility Master Plan Page 683 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 13-Ozone Contact + ICA WTM-Field Instruments-63
Instrumentation and
Controls 2010 2-ME-11

OZONE RESIDUAL ANALYZER - CONTACT BASIN, OZONE
DESTRUCT ROOM, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 13-Ozone Contact + ICA WTM-Field Instruments-64
Instrumentation and
Controls 2010 2-ME-7
OFF GAS ANALYZER, OZONE BASIN 1, OZONE DESTRUCT ROOM,
WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 2 No Action Required
Process/Facility Operates Normally
Without 1 2 8 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-65
Instrumentation and
Controls 2010 FIT-829
FL2 FLOW METER, FLUORIDE, INTERMEDIATE CHEMICAL
ADDITION, Field Instruments Flow 2
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 3 24 Low
WTM 13-Ozone Contact + ICA WTM-Field Instruments-66
Instrumentation and
Controls 1990 362 GAUGE, DIFFERENTIAL PRESSURE, OZONE BASIN 1, EAST TRAIN Field Instruments Pressure -18 Replace or Run to
Failure
Process/Facility Operates Normally
Without 2 2 14 Low
WTM 14-Filters WTM-Field Instruments-67
Instrumentation and
Controls 2009 AE/AIT-609
AE/AIT-609, PARTICLE COUNTER, FILTER 10, FILTER GALLERY, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-68
Instrumentation and
Controls 2009 AE/AIT-619
AE/AIT-619, PARTICLE COUNTER, FILTER 01, FILTER GALLERY, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-69
Instrumentation and
Controls 2009 AE/AIT-629
AE/AIT, TRANSMITTER, PARTICLE COUNTER, FILTER 02, FILTER GALLERY, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 11-Intake / LLPS WTM-Field Instruments-7
Instrumentation and
Controls 2016 CNL-AE-105 CNL-AE-105, CANAL ORP SENSOR, CANAL SHACK, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 8 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 14-Filters WTM-Field Instruments-70
Instrumentation and
Controls 2009 AE/AIT-639
AE/AIT-639, TRANSMITTER, PARTICLE COUNTER, FILTER 03,
FILTER GALLERY, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-71
Instrumentation and
Controls 2009 AE/AIT-649
AE/AIT-649, PARTICLE COUNTER TRANSMITTER, FILTER 04,
FILTER GALLERY, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-72
Instrumentation and
Controls 2009 AE/AIT-659
AE/AIT-659, PARTICLE COUNTER TRANSMITTER, FILTER 5, FILTER GALLERY, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-73
Instrumentation and
Controls 2009 AE/AIT-669 AE/AIT-669, PARTICLE COUNTER, FILTER 6, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-74
Instrumentation and
Controls 2009 AE/AIT-679 AE/AIT, PARTICLE COUNTER, FILTER 7, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-75
Instrumentation and
Controls 2009 AE/AIT-689 AE/AIT-687, PARTICLE COUNTER, FILTER 8, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-76
Instrumentation and
Controls 2009 AE/AIT-699 AE/AIT-699, PARTICLE COUNTER, FILTER 9, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-77
Instrumentation and
Controls 2009 AE/AIT-717 PARTICLE COUNTER, APPLIED WATER, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-78
Instrumentation and
Controls 2009 AE-131 AE-131, TURBIDITY, APPLIED WATER, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-79
Instrumentation and
Controls 2009 AE-608 AE-608, TURBIDITY, FILTER 10, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 11-Intake / LLPS WTM-Field Instruments-8
Instrumentation and
Controls 2016 CNL-AE-204
CNL-AE-204, BRIDGE CONDUCTIVITY SENSOR, CANAL SHACK,
WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 8 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 14-Filters WTM-Field Instruments-80
Instrumentation and
Controls 2009 AE-618 F1 TURBIDITY, Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-81
Instrumentation and
Controls 2009 AE-628 AE-628, TURBIDITY, FILTER 02, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-82
Instrumentation and
Controls 2009 AE-638 AE-638, TURBIDITY, FILTER 03, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-83
Instrumentation and
Controls 2009 AE-648 AE-648, TURBIDITY, FILTER 4, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-84
Instrumentation and
Controls 2009 AE-658 AE-658, TURBIDITY, FILTER 5, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-85
Instrumentation and
Controls 2009 AE-668 FILTER 6 Turbidimeter, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-86
Instrumentation and
Controls 2009 AE-678 AE-678, TURBIDITY, FILTER 7, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-87
Instrumentation and
Controls 2009 AE-688 AE-688, TURBIDITY, FILTER 8, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-88
Instrumentation and
Controls 2009 AE-698 AE-698, TURBIDITY, FILTER 9, FILTER GALLERY, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 14-Filters WTM-Field Instruments-89
Instrumentation and
Controls 2009 AIT-130
AIT-130, TRANSMITTER, PH/TEMP & TURBIDITY, APPLIED
WATER, FILTER GALLERY, WTP Field Instruments
Field Instruments (pH,
chlorine, turbidity, etc.) 1
Replace or Run to
Failure Reduced Efficiency 2 4 32 Med-Low
WTM 11-Intake / LLPS WTM-Field Instruments-9
Instrumentation and
Controls 2016 CNL-AE-205 CNL-AE-205, BRIDGE ORP SENSOR, CANAL SHACK, WTP Field Instruments Field Instruments (pH,
chlorine, turbidity, etc.) 8 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 14-Filters WTM-Field Instruments-90
Instrumentation and
Controls 2009 FIT-599 FIT-599, FLOW TRANSMITTER, FILTER 10, FILTER GALLERY, WTP Field Instruments Flow 1 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 3 21 Low
WTM 14-Filters WTM-Field Instruments-91
Instrumentation and
Controls 2009 FIT-700
Chem Mix FLOW METER, CFE POST FILTRATION CHEMICAL
MIXING WATER, FILTER GALLERY, WTP Field Instruments Flow 1 Replace or Run to
Failure Reduced Efficiency 2 4 28 Med-Low
WTM 14-Filters WTM-Field Instruments-92
Instrumentation and
Controls 2009 LT-620 LT-620, TRANSMITTER, LEVEL, FILTER 2, FILTER DECK, WTP Field Instruments Level Element 1 Replace or Run to
Failure Reduced Efficiency 2 4 28 Med-Low
WTM 14-Filters WTM-Field Instruments-93
Instrumentation and
Controls 2009 PIT-607
PIT-607, HEADLOSS TRANSMITTER, FILTER 10, FILTER GALLERY, WTP Field Instruments Pressure 1 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 14-Filters WTM-Field Instruments-94
Instrumentation and
Controls 2009 PIT-617
PIT-617, HEAD LOSS TRANSMITTER, PRESSURE, FILTER 1, FILTER GALLERY, WTP Field Instruments Pressure 1 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 14-Filters WTM-Field Instruments-95
Instrumentation and
Controls 2009 PIT-627
PIT-627, PRESSURE TRANSMITTER, HEAD LOSS, FILTER 2, FILTER GALLERY, WTP Field Instruments Pressure 1 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 14-Filters WTM-Field Instruments-96
Instrumentation and
Controls 2009 PIT-637
PIT-637, HEAD LOSS TRANSMITTER, FILTER 3, FILTER GALLERY, WTP Field Instruments Pressure 1 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 14-Filters WTM-Field Instruments-97
Instrumentation and
Controls 2009 PIT-647
PIT-647, HEAD LOSS TRANSMITTER, FILTER 4, FILTER GALLERY, WTP Field Instruments Pressure 1 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 14-Filters WTM-Field Instruments-98
Instrumentation and
Controls 2009 PIT-657
PIT-657, HEAD LOSS TRANSMITTER, FILTER 5, FILTER GALLERY, WTP Field Instruments Pressure 1 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 14-Filters WTM-Field Instruments-99
Instrumentation and
Controls 2009 PIT-667
PIT-667, HEAD LOSS TRANSMITTER, FILTER 6, FILTER GALLERY, WTP Field Instruments Pressure 1 Rehabilitation Reduced Efficiency 2 4 24 Med-Low

Page 12 of 24 ends

Clity of Fairfield
Utility Master Plan Page 684 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 11-Intake / LLPS WTM-Mechanical-1 Mechanical Systems 1974 DS-MOG-2 SLUICE GATE- MOTORIZED, Mechanical Other (Mechanical) -29 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 6 48 High
WTM 12-Pretreatment WTM-Mechanical-10 Mechanical Systems 2010 AF-GEQ-12 AF1 HYDROCYCLONE 2, ACTIFLO EAST TRAIN, WTP Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 3 12 Med-Low
WTM 12-Pretreatment WTM-Mechanical-11 Mechanical Systems 2010 AF-GEQ-13 AF1 HYDROCYCLONE 3, ACTIFLO EAST TRAIN, WTP Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 3 12 Med-Low
WTM 12-Pretreatment WTM-Mechanical-12 Mechanical Systems 2010 AF-GEQ-14 SAND SCRAPER, EAST TRAIN, WTP Mechanical Other (Mechanical) 7 Increased
Maintenance Process/Facility Cannot Operate Without 4 9 45 High WTM 12-Pretreatment WTM-Mechanical-13 Mechanical Systems 2010 AF-GEQ-21 AF2 HYDROCYCLONE 1, WEST ACTIFLO, WTP Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 3 12 Med-Low
WTM 12-Pretreatment WTM-Mechanical-14 Mechanical Systems 2010 AF-GEQ-22 AF2 HYDROCYCLONE 2, WEST ACTIFLO, WTP Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 3 12 Med-Low
WTM 12-Pretreatment WTM-Mechanical-15 Mechanical Systems 2010 AF-GEQ-23 AF2 HYDROCYCLONE 3, WEST ACTIFLO, WTP Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 3 12 Med-Low
WTM 12-Pretreatment WTM-Mechanical-16 Mechanical Systems 2010 AF-MIX-11 AF1 COAG MIXER, ACTIFLO EAST TRAIN, WTP Mechanical Mixer 7 No Action Required Process/Facility Cannot Operate Without 3 9 36 High WTM 12-Pretreatment WTM-Mechanical-17 Mechanical Systems 2010 AF-MIX-12 AF1 INJECTION MIXER, ACTIFLO EAST TRAIN, WTP Mechanical Mixer 7 No Action Required Process/Facility Cannot Operate Without 3 9 36 High WTM 12-Pretreatment WTM-Mechanical-18 Mechanical Systems 2010 AF-MIX-13 AF1 MATURATION MIXER, ACTIFLO EAST TRAIN, WTP Mechanical Mixer 7 Increased
Maintenance Process/Facility Cannot Operate Without 4 9 45 High WTM 12-Pretreatment WTM-Mechanical-19 Mechanical Systems 2010 AF-MIX-14 AF-MIX-14, SAND SCRAPER, WEST TRAIN, WTP Mechanical Other (Mechanical) 7 Increased
Maintenance Process/Facility Cannot Operate Without 4 9 45 High WTM 11-Intake / LLPS WTM-Mechanical-2 Mechanical Systems 1974 DS-MOG-1 Drum Screen Gate MOV, Mechanical Other (Mechanical) -29 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 6 48 High
WTM 12-Pretreatment WTM-Mechanical-20 Mechanical Systems 2010 AF-MIX-21 AF2 COAG MIXER, WEST ACTIFLO, WTP Mechanical Mixer 7 No Action Required Process/Facility Cannot Operate Without 3 9 36 High WTM 12-Pretreatment WTM-Mechanical-21 Mechanical Systems 2010 AF-MIX-22 AF2 INJECTION MIXER, WEST ACTIFLO, WTP Mechanical Mixer 7 No Action Required Process/Facility Cannot Operate Without 3 9 36 High WTM 12-Pretreatment WTM-Mechanical-22 Mechanical Systems 2010 AF-MIX-23 AF2 MATURATION MIXER, WEST ACTIFLO, WTP Mechanical Mixer 7 Increased
Maintenance Process/Facility Cannot Operate Without 4 9 45 High WTM 12-Pretreatment WTM-Mechanical-23 Mechanical Systems 2010 AF-HO-1 AF-HO-1, SAND HOPPER HOIST, AF SAND STORAGE, 2 TON
HARRINGTON MONORAIL, WTP Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 12-Pretreatment WTM-Mechanical-24 Mechanical Systems 2010 AF-MEQ-31 AF-MEQ-31, HOPPER, SAND, WTP Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 4 16 Med-Low
WTM 13-Ozone Contact + ICA WTM-Mechanical-25 Mechanical Systems 2010 PLC51 FlashMix Mechanical Mixer 7 Replace or Run to
Failure Reduced Efficiency 6 6 54 High
WTM 13-Ozone Contact + ICA WTM-Mechanical-26 Mechanical Systems 1974 ICA-MOG-1 ICA-MOG-1, SLUICE GATE, EFFLUENT, ICA, WTP Mechanical Other (Mechanical) -29 Replace or Run to
Failure
Process/Facility Operates Normally
Without 5 5 35 Med-High
WTM 13-Ozone Contact + ICA WTM-Mechanical-27 Mechanical Systems 1974 ICA-MOG-2 ICA-MOG-2, SLUICE GATE, EFFLUENT, ICA, WTP Mechanical Other (Mechanical) -29 Replace or Run to
Failure
Process/Facility Operates Normally
Without 5 5 35 Med-High
WTM 13-Ozone Contact + ICA WTM-Mechanical-28 Mechanical Systems 2010 OC-MOG-1 SLUICE GATE @ OZ CONTACTOR INFLUENT CHANNEL, WTP Mechanical Other (Mechanical) 7 No Action Required Process/Facility Cannot Operate Without 3 9 36 High WTM 13-Ozone Contact + ICA WTM-Mechanical-29 Mechanical Systems 2010 OC-MOG-2 SLUICE GATE, OZ CONTACTOR BYPASS, WTP Mechanical Other (Mechanical) 7 No Action Required Process/Facility Cannot Operate Without 3 9 36 High WTM 11-Intake / LLPS WTM-Mechanical-3 Mechanical Systems 1974

INTAKE-DRUM
SCREEN 2 Drum Screen 2 Mechanical Other (Mechanical) -29 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 4 20 Medium
WTM 13-Ozone Contact + ICA WTM-Mechanical-30 Mechanical Systems 1990 2-ME-10 OZONE PURGE BLOWER, CONTACTORS 1-4 PURGE, OZONE
DESTRUCT RM, WTP Mechanical Other (Mechanical) -13 Rehabilitation Process/Facility Operates Normally
Without 2 3 18 Low
WTM 13-Ozone Contact + ICA WTM-Mechanical-31 Mechanical Systems 1990 2-ME-5 OZONE DESTRUCT UNIT 1, OZONE DESTRUCT ROOM, WTP Mechanical Other (Mechanical) -13 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 4 24 Medium
WTM 13-Ozone Contact + ICA WTM-Mechanical-32 Mechanical Systems 1990 2-ME-6 OZONE DESTRUCT UNIT 2, OZONE DESTRUCT ROOM, WTP Mechanical Other (Mechanical) -13 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 4 24 Medium
WTM 16-Chemicals WTM-Mechanical-33 Mechanical Systems 2010 CF-MIX-2 MIXER- POLY BLENDING TK 6, NORTH POLYBLEND, Mechanical Mixer 7 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 17-Ozone Generation WTM-Mechanical-34 Mechanical Systems 1990 OG-O3G-1 OG-O3G-1, VESSEL, OZONE GENERATOR 1, OZONE GENERATOR
ROOM, WTP Mechanical Other (Mechanical) -13 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 6 5 30 Med-High
WTM 17-Ozone Generation WTM-Mechanical-35 Mechanical Systems 1990 OG-O3G-2 OG-O3G-2, VESSEL, OZONE GENERATOR 2, OZONE GENERATOR
ROOM, WTP Mechanical Other (Mechanical) -13 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 6 5 30 Med-High
WTM 17-Ozone Generation WTM-Mechanical-36 Mechanical Systems 2010 OG-O3G-3 OG-O3G-3, VESSEL, OZONE GENERATOR 3, OZONE GENERATOR
ROOM, WTP Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 4 5 20 Med-High
WTM 19-Sludge Clarifiers and Lagoons WTM-Mechanical-37 Mechanical Systems 2010 SL-MOG-1 EFFLUENT GATE MOG, LAGOON 1 Mechanical Other (Mechanical) 7 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 5 30 Medium
WTM 19-Sludge Clarifiers and Lagoons WTM-Mechanical-38 Mechanical Systems 2010 SL-MOG-2 EFFLUENT GATE MOG, LAGOON 2 Mechanical Other (Mechanical) 7 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 5 30 Medium
WTM 19-Sludge Clarifiers and Lagoons WTM-Mechanical-39 Mechanical Systems 2010 SL-MOG-3 EFFLUENT GATE MOG, LAGOON 3 Mechanical Other (Mechanical) 7 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 5 30 Medium
WTM 11-Intake / LLPS WTM-Mechanical-4 Mechanical Systems 1974 DS-MEQ-2 DRUM SCREEN 2, Mechanical Other (Mechanical) -29 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 4 20 Medium
WTM 19-Sludge Clarifiers and Lagoons WTM-Mechanical-40 Mechanical Systems 2010 SC-CLR-1 CLARIFIER #1 RAKE MOTOR, Mechanical Other (Mechanical) 7 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 5 30 Medium
WTM 19-Sludge Clarifiers and Lagoons WTM-Mechanical-41 Mechanical Systems 2010 SC-CLR-2 CLARIFIER #2 RAKE MOTOR, Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 5 20 Medium
WTM 19-Sludge Clarifiers and Lagoons WTM-Mechanical-42 Mechanical Systems 2010 SC-MIX-1 CLARIFIER #1 TURBINE PROPELLER MOTOR, Mechanical Other (Mechanical) 7 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 5 30 Medium
WTM 19-Sludge Clarifiers and Lagoons WTM-Mechanical-43 Mechanical Systems 2010 SC-MIX-2 CLARIFIER #2 TURBINE PROPELLER MOTOR, SOLIDS HANDLING, Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 5 20 Medium
WTM 00-Misc Systems WTM-Mechanical-44 Mechanical Systems 2010 OG-TNK-1 OG-TNK-1, NITROGEN COMPRESSED AIR RECEIVER, NITROGEN
BOOST SKID, OZONE GEN RM, WTP Mechanical Other (Mechanical) 7 No Action Required Reduced Efficiency 3 6 24 Med-High WTM 11-Intake / LLPS WTM-Mechanical-5 Mechanical Systems 2010

INTAKE-DRUM
SCREEN 1 Drum Screen 1 Mechanical Other (Mechanical) 7 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 4 24 Medium

Page 13 of 24 ends

Clity of Fairfield
Utility Master Plan Page 685 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 11-Intake / LLPS WTM-Mechanical-6 Mechanical Systems 2010 DS-MEQ-1 DRUM SCREEN 1, Mechanical Other (Mechanical) 7 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 4 24 Medium
WTM 11-Intake / LLPS WTM-Mechanical-7 Mechanical Systems 2010 DS-MTR-1 P1 Drum Screen Motor, Mechanical Other (Mechanical) 7 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 5 30 Medium
WTM 12-Pretreatment WTM-Mechanical-8 Mechanical Systems 2010 AF-MOG-10 SLUICE GATE, EFF CHANNEL, WTP Mechanical Other (Mechanical) 7 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 5 6 42 Med-High
WTM 12-Pretreatment WTM-Mechanical-9 Mechanical Systems 2010 AF-GEQ-11 AF HYDROCYCLONE 1, ACTIFLO EAST TRAIN, WTP Mechanical Other (Mechanical) 7 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 3 12 Med-Low
WTM 17-Ozone Generation WTM-Valves-248 Mechanical Systems 1990 OG-MOV-13 OG-MOV-13, VALVE, 2 BUTTERFLY, OZONE GENERATOR 1
COOLING SUPPLY, OZONE GENERATOR ROOM, WTP Valves Butterfly -8 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 16-Chemicals WTM-Other-1 Other 2010 EQUIPMENT-14
CF-EW-4, EYE WASH STATION, FLUORIDE PUMP ROOM, CHEM
BLDG, WTP Other / Uncategorized Eyewash #VALUE!
Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Other-10 Other 2010 EQUIPMENT-23
CS-EW-6, EYE WASH STATION, BASE OFFLOAD AREA, SOUTH
TANK FARM, CHEM BLDG, WTP Other / Uncategorized Eyewash #VALUE! Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Other-11 Other 2014
CO2-CONTROL
CABINET Control Cabinet Other / Uncategorized Other / Uncategorized #VALUE! Rehabilitation Reduced Efficiency 2 5 30 Medium WTM 16-Chemicals WTM-Other-12 Other 2014 CO2-FILL CO2 LIQUID FILL CONNECTION, WTP Other / Uncategorized Other / Uncategorized #VALUE! Rehabilitation Reduced Efficiency 2 5 30 Medium WTM 16-Chemicals WTM-Other-14 Other 2014
CO2-FILL AND
RETURN
CONNECTION Tank Fill and Return Connection Other / Uncategorized Other / Uncategorized #VALUE! Rehabilitation Reduced Efficiency 2 5 30 Medium WTM 16-Chemicals WTM-Other-15 Other 2014 CO2-HEATER Heater Other / Uncategorized Other / Uncategorized #VALUE! Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 16-Chemicals WTM-Other-16 Other 2014 CO2-MEQ-1 CO2 HEATER CONTROLLER, 375 LBS PER HR, WTP Other / Uncategorized Other / Uncategorized #VALUE! Rehabilitation Reduced Efficiency 2 5 30 Medium WTM 16-Chemicals WTM-Other-17 Other 2014 CO2-PIPING Piping Line Valves Other / Uncategorized Other / Uncategorized #VALUE! Rehabilitation Reduced Efficiency 2 5 30 Medium WTM 16-Chemicals WTM-Other-2 Other 2010 EQUIPMENT-15
CF-EW-1, EYE WASH STATION, POLYBLEND ROOM, CHEM BLDG,
WTP Other / Uncategorized Eyewash #VALUE!
Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Other-3 Other 2010 EQUIPMENT-16
CF-EW-2, EYE WASH STATION, ACID CHEM PUMP AREA, CHEM
BLDG, WTP Other / Uncategorized Eyewash #VALUE!
Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Other-4 Other 2010 EQUIPMENT-17
CF-EW-3, EYE WASH STATION, BASE CHEM PUMP AREA, CHEM
BLDG, WTP Other / Uncategorized Eyewash #VALUE!
Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Other-5 Other 2010 EQUIPMENT-18
CS-EW-1, EYE WASH STATION, ACID CHEM OFFLOAD, NORTH
TANK FARM, CHEM BLDG, WTP Other / Uncategorized Eyewash #VALUE! Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Other-6 Other 2010 EQUIPMENT-19
CS-EW-2, EYE WASH STATION, ACID TANK FARM, WEST END,
CHEM BLDG, WTP Other / Uncategorized Eyewash #VALUE!
Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Other-7 Other 2010 EQUIPMENT-20
CS-EW-3, EYE WASH STATION, ACID TANK FARM, EAST END,
CHEM BLDG, WTP Other / Uncategorized Eyewash #VALUE!
Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Other-8 Other 2010 EQUIPMENT-21
CS-EW-4, EYE WASH STATION, BASE TANK FARM, WEST END,
CHEM BLDG, WTP Other / Uncategorized Eyewash #VALUE!
Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Other-9 Other 2010 EQUIPMENT-22
CS-EW-5, EYE WASH STATION, BASE TANK FARM, EAST END,
CHEM BLDG, WTP Other / Uncategorized Eyewash #VALUE!
Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 11-Intake / LLPS WTM-Pump-1 Mechanical Systems 2010 CNL-PMP-1 CNL-PMP-1, PUMP, SUBMERSIBLE, CANAL WATER QUALITY
PUMP FROM BRIDGE TO WQ SHACK, WTP Pump Submersible 17
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 12-Pretreatment WTM-Pump-10 Mechanical Systems 2010 FM-PMP-1 FM-PMP-1, FLASH MIX PUMP 1, OPS BASEMENT, WTP Pump Other (Pump) 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 4 16 Med-Low
WTM 12-Pretreatment WTM-Pump-11 Mechanical Systems 2010 FM-PMP-2 FM-PMP-2, FLASH MIX PUMP 2, OPS BASEMENT, WTP Pump Other (Pump) 17 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 4 20 Medium
WTM 12-Pretreatment WTM-Pump-12 Mechanical Systems 2010 FM-PMP-3 FM-PMP-3, INFLUENT FLOW SAMPLE PUMP, FLASH MIX, OPS
BASEMENT, WTP Pump Sample 2 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 12-Pretreatment WTM-Pump-13 Mechanical Systems 2010 FM-PMP-4 COAGULATED SAMPLE PUMP, FLASH MIX, OPS BASEMENT, WTP Pump Sample 2 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 12-Pretreatment WTM-Pump-14 Mechanical Systems 2010 AF-PMP-11 SAND PUMP 1- EAST ACTIFLO, Pump Other (Pump) 17 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 4 20 Medium
WTM 12-Pretreatment WTM-Pump-15 Mechanical Systems 2010 AF-PMP-12 SAND PUMP 2 - EAST ACTIFLO, Pump Other (Pump) 17 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 4 20 Medium
WTM 12-Pretreatment WTM-Pump-16 Mechanical Systems 2010 AF-PMP-13 SAND PUMP 3 - EAST ACTIFLO, Pump Other (Pump) 17 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 4 20 Medium
WTM 12-Pretreatment WTM-Pump-17 Mechanical Systems 2010 AF-PMP-14 WATER QUALITY SAMPLE PUMP - EAST ACTIFLO, Pump Sample 2 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 12-Pretreatment WTM-Pump-18 Mechanical Systems 2010 AF-PMP-21 SAND PUMP 1- WEST ACTIFLO, Pump Other (Pump) 17 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 4 20 Medium
WTM 12-Pretreatment WTM-Pump-19 Mechanical Systems 2010 AF-PMP-22 SAND PUMP 2-WEST ACTIFLO, Pump Other (Pump) 17 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 4 20 Medium
WTM 11-Intake / LLPS WTM-Pump-2 Mechanical Systems 1974 DS-PMP-2 PUMP 2 - SCREEN WASH Pump Other (Pump) -19 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 12-Pretreatment WTM-Pump-20 Mechanical Systems 2010 AF-PMP-23 AF-PMP-23, SAND PUMP 3, WEST ACTIFLO, WTP Pump Other (Pump) 17 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 4 20 Medium
WTM 12-Pretreatment WTM-Pump-21 Mechanical Systems 2010 AF-PMP-24 WATER QUALITY SAMPLE PUMP , WEST ACTIFLO, Pump Sample 2 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 13-Ozone Contact + ICA WTM-Pump-22 Mechanical Systems 2010 OC-PMP-1 OC-PMP-1, OZONE CONTACTOR DRAIN SUMP PUMP 1, OZONE
CONTACTOR, WTP Pump Sump 17 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 4 24 Med-Low
WTM 13-Ozone Contact + ICA WTM-Pump-23 Mechanical Systems 2010 OC-PMP-2 OZONE CONTACTOR DRAIN SUMP PUMP 2, OZONE CONTACTOR
GALLERY, WTP Pump Sump 17 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 13-Ozone Contact + ICA WTM-Pump-24 Mechanical Systems 2010 OC-PMP-3 OC-PMP-3, OZONE CONTACTOR DRAIN SUMP PUMP 3, OZONE
CONTACTOR GALLERY, WTP Pump Sump 17 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 14-Filters WTM-Pump-25 Mechanical Systems 2010 FS-PMP-10 FS-PMP-10, FILTER TO WASTE PUMP 1, FILTER GALLERY, WTP Pump Other (Pump) 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 14-Filters WTM-Pump-26 Mechanical Systems 2010 FS-PMP-20 FS-PMP-20, FILTER TO WASTE PUMP 2, FILTER GALLERY, WTP Pump Other (Pump) 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 14-Filters WTM-Pump-27 Mechanical Systems 2010 FG-SP-1 SUMP PUMP 1, SUBMERSIBLE, FILTER GALLERY DRAIN, WTP Pump Sump 17 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 14-Filters WTM-Pump-28 Mechanical Systems 2010 FG-SP-2 SUMP PUMP 2, SUBMERSIBLE, FILTER GALLERY DRAIN, WTP Pump Sump 17 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 14-Filters WTM-Pump-29 Mechanical Systems 2010 FG-SP-24 APPLIED SAMPLE PUMP, FILTER GALLERY, WTP Pump Sample 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low

Page 14 of 24 ends

Clity of Fairfield
Utility Master Plan Page 686 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 11-Intake / LLPS WTM-Pump-3 Mechanical Systems 1974 DS-MTR-2 PUMP 2 MOTOR, Pump Other (Pump) -19 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Pump-30 Mechanical Systems 2012

FG-SAMPLE
PUMP Sample Pump Pump Sample 4 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 14-Filters WTM-Pump-31 Mechanical Systems 2012 WR-PMP-7 SUMP PUMP #1 (NORTH), RPS, WTP Pump Sump 19 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 15-HLPS WTM-Pump-32 Mechanical Systems 1986 HL-PMP-4 HL-PMP-4, PUMP 4, VERTICAL TURBINE, HLPS, WTP Pump Vertical Turbine -7 Replace or Run to
Failure Reduced Capacity/Pressure 6 7 63 High
WTM 15-HLPS WTM-Pump-33 Mechanical Systems 1986 HL-PMP-P6 HighLift P1, VERTICAL TURBINE, Pump Vertical Turbine -7 Replace or Run to
Failure Reduced Capacity/Pressure 6 7 63 High
WTM 15-HLPS WTM-Pump-34 Mechanical Systems 1986 HL-PMP-P7 HL-PMP-P7, PUMP 2, VERTICAL TURBINE, HLPS, WTP Pump Vertical Turbine -7 Replace or Run to
Failure Reduced Capacity/Pressure 6 7 63 High
WTM 15-HLPS WTM-Pump-35 Mechanical Systems 1986 HL-PMP-P8 HL-PMP-P8, PUMP 3, VERTICAL TURBINE, HLPS, WTP Pump Vertical Turbine -7 Replace or Run to
Failure Reduced Capacity/Pressure 6 7 63 High
WTM 15-HLPS WTM-Pump-36 Mechanical Systems 2010 HL-PMP-5 HL-PMP-5, PUMP 5, VERTICAL TURBINE, HLPS, WTP Pump Vertical Turbine 17 Replace or Run to
Failure Reduced Capacity/Pressure 6 7 56 High
WTM 15-HLPS WTM-Pump-37 Mechanical Systems 2010 HL-PMP-6 HL-PMP-6, CFE SAMPLE PUMP, GRUNDFOS WELL PUMP, .5 HP,
115V, 3 WIRE, HLPS, WTP Pump Sample 2 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 15-HLPS WTM-Pump-38 Mechanical Systems 2012 SP-3

SUMP PUMP, HI VOLTAGE VAULT (WEST OF HLPS CONT BLDG),
HLPS, WTP Pump Sump 19 Rehabilitation
Process/Facility Operates Normally
Without 2 2 12 Low
WTM 16-Chemicals WTM-Pump-39 Mechanical Systems 2010 CF PMP 53 CF-PMP-53, PUMP 3, METERING, ANIONIC FLOC AID POLY, CHEM BLDG, WTP Pump Metering 2 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 11-Intake / LLPS WTM-Pump-4 Mechanical Systems 1985 LLPS-P3 LLPS Pump 3 Pump Other (Pump) -8 Rehabilitation Reduced Efficiency 4 5 30 Med-High WTM 16-Chemicals WTM-Pump-40 Mechanical Systems 2010 CF PMP 54 CF-PMP-54, PROGRESSIVE CAVITY PUMP, MOYNO, EMULSION
FEED, SOUTH POLYBLEND, CHEM BLDG, WTP Pump Metering 2 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 4 24 Medium
WTM 16-Chemicals WTM-Pump-41 Mechanical Systems 2010 CF-CMP-1 COMPRESSOR - SOUTH POLYBLEND, Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 16-Chemicals WTM-Pump-42 Mechanical Systems 2010 CF-CMP-2 COMPRESSOR - NORTH POLYBLEND Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 16-Chemicals WTM-Pump-43 Mechanical Systems 2010 CF-MEQ-1 DISPERSER-SOUTH POLYBLEND, CHEM BLDG, WTP Pump Metering 2 Rehabilitation Process/Facility Cannot Operate Without 2 9 54 High WTM 16-Chemicals WTM-Pump-44 Mechanical Systems 2010 CF-MEQ-2 DISPERSER - NORTH POLYBLEND, Pump Metering 2 Rehabilitation Process/Facility Cannot Operate Without 2 9 54 High WTM 16-Chemicals WTM-Pump-45 Mechanical Systems 2010 CF-PMP-12 CF-PMP-12, PUMP, METERING, ALUM FEED 2, CHEM BLDG, WTP Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-46 Mechanical Systems 2010 CF-PMP-13 CF-PMP-13, PUMP, METERING, ALUM FEED 3, CHEM BLDG, WTP Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-47 Mechanical Systems 2010 CF-PMP-21 CF-PMP-21, METERING PUMP 1, CAUSTIC FEED, FILTERED
WATER, CHEM BLDG, WTP Pump Metering 2
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-48 Mechanical Systems 2010 CF-PMP-22 Caustic Feed METERING PUMP 2, Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-49 Mechanical Systems 2010 CF-PMP-23 METERING PUMP 3, UP FRONT CAUSTIC 3, CHEM BLDG, WTP Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 11-Intake / LLPS WTM-Pump-5 Mechanical Systems 1985 LLPS-P4 LLPS Pump 4 Pump Other (Pump) -8 Replace or Run to
Failure Reduced Efficiency 6 5 45 Med-High
WTM 16-Chemicals WTM-Pump-50 Mechanical Systems 2010 CF-PMP-24 METERING PUMP 4, UP FRONT CAUSTIC, CHEM BLDG, WTP Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-51 Mechanical Systems 2010 CF-PMP-31 PUMP 1, METERING, FLUORIDE FEED, FLUORIDE ROOM, CHEM
BLDG Pump Metering 2
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-52 Mechanical Systems 2010 CF-PMP-32 PUMP 2, METERING, FLUORIDE FEED, FLUORIDE ROOM, CHEM
BLDG Pump Metering 2
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-53 Mechanical Systems 2010 CF-PMP-41 Hypo 1 Metering Pump Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-54 Mechanical Systems 2010 CF-PMP-42 CF-PMP-42, PUMP, METERING, HYPO 2, CHEM BLDG, WTP Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-55 Mechanical Systems 2010 CF-PMP-43 Hypo 3 Metering Pump , Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-56 Mechanical Systems 2010 CF-PMP-51 CF-PMP-51, PUMP 1, METERING, ANIONIC FLOC AID POLY, CHEM BLDG, WTP Pump Metering 2
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-57 Mechanical Systems 2010 CF-PMP-52x Pump 2 ANIONIC FLOC AID Pump 2 Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-58 Mechanical Systems 2010 CF-PMP-61 PUMP 1, METERING, CATIONIC FILTER AID POLY, CHEM BLDG Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-59 Mechanical Systems 2010 CF-PMP-62 PUMP 2, METERING, CATIONIC FILTER AID POLY 2, Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 11-Intake / LLPS WTM-Pump-6 Mechanical Systems 2010 DS-PMP-1 Screen Wash P1, Drum Screen Wash Pump Pump Other (Pump) 17 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 16-Chemicals WTM-Pump-60 Mechanical Systems 2010 CF-PMP-71 ACH Feed PUMP 1, ACH FEED 1, CHEM BLDG, WTP Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-61 Mechanical Systems 2010 CF-PMP-72 PUMP, METERING, ACH FEED 2, CHEM BLDG, WTP Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-62 Mechanical Systems 2010 CF-PMP-81 CF-PMP-81, PUMP 1, METERING, CLARIFIER POLY FEED, CHEM
BLDG, WTP Pump Metering 2
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-63 Mechanical Systems 2010 CF-PMP-82 PUMP 2, METERING, CLARIFIER POLY FEED, CHEM BLDG, WTP Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-64 Mechanical Systems 2010 CF-PMP-83 CF-PMP-83, PROGRESSIVE CAVITY PUMP, MOYNO, EMULSION
FEED, NORTH POLYBLEND, CHEM BLDG, WTP Pump Metering 2
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-65 Mechanical Systems 2010 CF-PMP-91 PUMP 1, METERING, NONIONIC FILTER POLY, CHEM BLDG, Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-66 Mechanical Systems 2010 CF-PMP-92 PUMP 2, METERING, NONIONIC FILTER POLY, CHEM BLDG, WTP Pump Metering 2 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low

Page 15 of 24 ends

Clity of Fairfield
Utility Master Plan Page 687 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 16-Chemicals WTM-Pump-67 Mechanical Systems 2010 CS-PMP-1 CS-PMP-1, SUBMERSIBLE PUMP, ACID SPILL CONTAINMENT
SUMP, WTP Pump Sump 17
Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Pump-68 Mechanical Systems 2010 CS-PMP-2 Base Side Chemical Sump Pump Pump Sump 17 Increased
Maintenance
Process/Facility Operates Normally
Without 2 2 10 Low
WTM 16-Chemicals WTM-Pump-69 Mechanical Systems 2010 CS-PMP-3 CS-PMP-3, HYPO MIX/TRANS PUMP, CHEM BLDG, WTP Pump Chemical Feed 2 Increased
Maintenance
Process/Facility Operates Normally
Without 2 3 15 Low
WTM 11-Intake / LLPS WTM-Pump-7 Mechanical Systems 2010 LLPS-P1 LLPS Pump 1 Pump Other (Pump) 17 Rehabilitation Reduced Capacity/Pressure 4 6 36 Med-High WTM 16-Chemicals WTM-Pump-70 Mechanical Systems 2010 CS-PMP-4 CS-PMP-4, CAUSTIC MIX/TRANS PUMP, SOUTH CHEM METERING
PUMP ROOM, CHEM BLDG, WTP Pump Metering 2
Increased
Maintenance
Process/Facility Operates Normally
Without 4 3 15 Med-Low
WTM 16-Chemicals WTM-Pump-71 Mechanical Systems 2010 CS-PMP-5 CS-PMP-5, ALUM TRANSFER PUMP, CHEM BLDG, WTP Pump Chemical Feed 2 Increased
Maintenance
Process/Facility Operates Normally
Without 2 3 15 Low
WTM 17-Ozone Generation WTM-Pump-72 Mechanical Systems 2012 LOX-SP-1 LOX-SP-1, SUBMESIBLE PUMP, LIQUID OXYGEN STORAGE TANK
AREA, WTP Pump Chemical Feed 4 Rehabilitation
Process/Facility Operates Normally
Without 2 2 12 Low
WTM 18-EQ Basin + WW PS WTM-Pump-73 Mechanical Systems 2010 WR-PMP-8 SUMP PUMP, #2 (SOUTH), RPS, WTP Pump Sump 17 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 4 24 Med-Low
WTM 18-EQ Basin + WW PS WTM-Pump-74 Mechanical Systems 2010 WR-PMP-9 FLOOR PUMP (SUMP OVERFLOW), RPS, WTP Pump Sump 17 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 4 24 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Pump-75 Mechanical Systems 2010 SL-PMP-1 UNDERDRAIN PUMP, SUBMERSIBLE, SLUDGE LAGOON 2, WTP Pump Submersible 17 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 4 24 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Pump-76 Mechanical Systems 2010 WR-PMP-1 DECANT PUMP 1, RPS, WTP Pump Other (Pump) 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 19-Sludge Clarifiers and Lagoons WTM-Pump-77 Mechanical Systems 2010 WR-PMP-2 DECANT PUMP 2, RPS, WTP Pump Other (Pump) 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 19-Sludge Clarifiers and Lagoons WTM-Pump-78 Mechanical Systems 2010 WR-PMP-3 SLUDGE PUMP 1, RPS, WTP Pump Other (Pump) 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 19-Sludge Clarifiers and Lagoons WTM-Pump-79 Mechanical Systems 2010 WR-PMP-4 SLUDGE PUMP 2, RPS, WTP Pump Other (Pump) 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 11-Intake / LLPS WTM-Pump-8 Mechanical Systems 2010 LLPS-P2 LLPS Pump 2 Pump Other (Pump) 17 Rehabilitation Reduced Capacity/Pressure 4 6 36 Med-High WTM 20-Operations Bldg WTM-Pump-80 Mechanical Systems 2012 WTP-SP-11 PUMP 1, SUMP, OPS BASEMENT DRAIN, WTP Pump Sump 19 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 20-Operations Bldg WTM-Pump-81 Mechanical Systems 2012 WTP-SP-12 PUMP 2, SUMP, OPS BASEMENT DRAIN, WTP Pump Sump 19 Rehabilitation Process/Facility Operates Normally
Without 2 2 12 Low
WTM 11-Intake / LLPS WTM-Pump-9 Mechanical Systems 2010 PUMP-20PB-E-1 SUMP PUMP, SUBMERSIBLE, VAULT 20PB-E-1, LLPS, WTP Pump Sump 17 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 3 18 Low
WTM 16-Chemicals WTM-Tank-1 Building and Grounds 2010 CF-MIX-1 MIXER- SOUTH POLY BLENDING MIX TANK 1, CHEM BLDG, WTP Tanks Chemical 17 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 16-Chemicals WTM-Tank-10 Building and Grounds 2010
CO2-BULK
STORAGE TANK Bulk Storage Tank Tanks Chemical 17 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 16-Chemicals WTM-Tank-11 Building and Grounds 2010 CO2-VAPORIZER Vaporizer Tanks Chemical 17 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 16-Chemicals WTM-Tank-12 Building and Grounds 2010 CS-TNK-1 CS-TNK-1, HYPO BULK STORAGE TANK 1, SOUTH TANK FARM,
WTP Tanks Chemical 17 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 16-Chemicals WTM-Tank-13 Building and Grounds 2010 CS-TNK-10 CAT POLY BULK STORAGE TANK, NORTH TANK FARM, WTP Tanks Chemical 17 No Action Required Reduced Efficiency 3 6 24 Med-High WTM 16-Chemicals WTM-Tank-14 Building and Grounds 2010 CS-TNK-2 CS-TNK-2, HYPO BULK STORAGE TANK 2, SOUTH TANK FARM,
WTP Tanks Chemical 17 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 16-Chemicals WTM-Tank-15 Building and Grounds 2010 CS-TNK-3 CAUSTIC BULK STORAGE TANK 1, SOUTH TANK FARM, WTP Tanks Chemical 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 16-Chemicals WTM-Tank-16 Building and Grounds 2010 CS-TNK-4 CAUSTIC BULK STORAGE TANK 2, SOUTH TANK FARM, WTP Tanks Chemical 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 16-Chemicals WTM-Tank-17 Building and Grounds 2010 CS-TNK-5 ACH BULK STORAGE TANK, NORTH TANK FARM, WTP Tanks Chemical 17 No Action Required Reduced Efficiency 3 6 24 Med-High WTM 16-Chemicals WTM-Tank-18 Building and Grounds 2010 CS-TNK-6 ALUM BULK STORAGE TANK 2, NORTH TANK FARM, WTP Tanks Chemical 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 16-Chemicals WTM-Tank-19 Building and Grounds 2010 CS-TNK-7 ALUM BULK STORAGE TANK 3, NORTH TANK FARM, WTP Tanks Chemical 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 16-Chemicals WTM-Tank-2 Building and Grounds 2010 CF-MIX-4 CF-MIX-4, MIXER, NON-I POLY, TANK 2, POLYBLEND ROOM,
CHEM BLDG, WTP Tanks Chemical 17 Rehabilitation
Process/Facility Operates Normally
Without 4 3 18 Med-Low
WTM 16-Chemicals WTM-Tank-20 Building and Grounds 2010 CS-TNK-8 FLUORIDE BULK STORAGE TANK 1, NORTH TANK FARM, WTP Tanks Chemical 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 16-Chemicals WTM-Tank-21 Building and Grounds 2010 CS-TNK-9 FLUORIDE BULK STORAGE TANK 2, NORTH TANK FARM, WTP Tanks Chemical 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 5 20 Medium
WTM 17-Ozone Generation WTM-Tank-22 Building and Grounds 1990 1-MEQ-1 EAST VAPORIZOR 1, LIQUID OXYGEN, 9,000 SCFH, LOX AREA,
WTP Tanks Chemical -3 Rehabilitation Reduced Efficiency 4 6 36 Med-High WTM 17-Ozone Generation WTM-Tank-23 Building and Grounds 1990 1-MEQ-2 WEST VAPORIZOR 2, LIQUID OXYGEN, 9,000 SCFH, LOX AREA,
WTP Tanks Chemical -3 Rehabilitation Reduced Efficiency 4 6 36 Med-High WTM 17-Ozone Generation WTM-Tank-24 Building and Grounds 1990 1-T-1 LOX STORAGE TANK 1, LOX STORAGE AREA, WTP Tanks Chemical -3 Replace or Run to
Failure Process/Facility Cannot Operate Without 5 9 63 High WTM 16-Chemicals WTM-Tank-3 Building and Grounds 2010 CF-MIX-5 CF-MIX-5, MIXER, NON-I POLY, TANK 1, POLYBLEND ROOM,
CHEM BLDG, WTP Tanks Chemical 17 Rehabilitation
Process/Facility Operates Normally
Without 4 3 18 Med-Low
WTM 16-Chemicals WTM-Tank-4 Building and Grounds 2010 CF-TNK-1 CAT/ANI POLYBLEND MIX TANK 1, Tanks Chemical 17 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 16-Chemicals WTM-Tank-5 Building and Grounds 2010 CF-TNK-2 CAT/ANI POLY FEED TANK, SOUTH POLYBLEND, Tanks Chemical 17 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 16-Chemicals WTM-Tank-6 Building and Grounds 2010 CF-TNK-4 CF-TNK-4, NONIONIC FILTER POLY FEED TANK 1, POLYBLEND
ROOM, CHEM BLDG, WTP Tanks Chemical 17 Rehabilitation
Process/Facility Operates Normally
Without 4 3 18 Med-Low
WTM 16-Chemicals WTM-Tank-7 Building and Grounds 2010 CF-TNK-5 CF-TNK-5, NONIONIC FILTER POLY FEED TANK 2, CHEM BLDG,
WTP Tanks Chemical 17 Rehabilitation
Process/Facility Operates Normally
Without 4 3 18 Med-Low
WTM 16-Chemicals WTM-Tank-8 Building and Grounds 2010 CF-TNK-6 CAT/ANI POLY MIXING TANK, NORTH POLYBLEND, Tanks Chemical 17 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High

Page 16 of 24 ends

Clity of Fairfield
Utility Master Plan Page 688 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 16-Chemicals WTM-Tank-9 Building and Grounds 2010 CF-TNK-7 CAT/ANI POLY FEED TANK, NORTH POLYBLEND, Tanks Chemical 17 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 11-Intake / LLPS WTM-Valves-1 Mechanical Systems 1974 ARV-LL-5 ARV-LL-5, AIR RELIEF VALVE, 42 DISCHARGE HEADER, LLPS, WTP Valves Air Valve -19 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 11-Intake / LLPS WTM-Valves-10 Mechanical Systems 2010 LL-CKV-3 LL-CKV-3, 24 CHECK VALVE, PUMP 3 EFFLUENT, LLPS, WTP Valves Check Valve 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 14-Filters WTM-Valves-100 Mechanical Systems 2010 F1-MO-15 F1-MO-15, WASTE WASHWATER ACTUATOR, FILTER 1, FILTER
DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-101 Mechanical Systems 2010 F1-MO-16 F1-MO-16, FILTER TO WASTE ACTUATOR, FILTER 1, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-102 Mechanical Systems 2010 F1-MOV-11 F1-MOV-11, INFLUENT VALVE, FILTER 1, 16 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-103 Mechanical Systems 2010 F1-MOV-12 F1-MOV-12, EFFLUENT VALVE, FILTER 1, 18 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-104 Mechanical Systems 2010 F1-MOV-13 F1-MOV-13, BACKWASH VALVE, FILTER 1, 24 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-105 Mechanical Systems 2010 F1-MOV-14 F1-MOV-14, AIR SCOUR VALVE, 8 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-106 Mechanical Systems 2010 F1-MOV-15 F1-MOV-15, WASTE WASHWATER VALVE, FILTER 1, 24 INCH
BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-107 Mechanical Systems 2010 F1-MOV-16 F1-MOV-16, FILTER TO WASTE VALVE, FILTER 1, 12 INCH
BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-108 Mechanical Systems 2010 F2-MO-21 INFLUENT VALVE ACTUATOR, FILTER 2, FILTER DECK, WTP Valves Other (Valves) 12 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-109 Mechanical Systems 2010 F2-MO-22 F2-MO-22, EFFLUENT VALVE ACTUATOR, FILTER 2, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 11-Intake / LLPS WTM-Valves-11 Mechanical Systems 2010 LL-CKV-4 LL-CKV-4, 24 CHECK VALVE, PUMP 4 EFFLUENT, LLPS, WTP Valves Check Valve 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 14-Filters WTM-Valves-110 Mechanical Systems 2010 F2-MO-23 F2-MO-23, BACKWASH VALVE ACTUATOR, FILTER 2, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 4 32 Med-High
WTM 14-Filters WTM-Valves-111 Mechanical Systems 2010 F2-MO-24 F2-MO-24, AIR SCOUR VALVE ACTUATOR, FILTER 2, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-112 Mechanical Systems 2010 F2-MO-25 F2-MO-25, WASTE WASHWATER VALVE ACTUATOR, FILTER 2,
FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-113 Mechanical Systems 2010 F2-MOV-21 FW-MOV-21, INFLUENT VALVE, FILTER 2, 16 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-114 Mechanical Systems 2010 F2-MOV-22 F2-MOV22, EFFLUENT VALVE, FILTER 2, 18 INCH BUTTERFLY,
FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-115 Mechanical Systems 2010 F2-MOV-23 FW-MOV-23, BACKWASH VALVE, FILTER 2, 24 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-116 Mechanical Systems 2010 F2-MOV-24 F2-MOV-24, AIR SCOUR VALVE, FILTER 2, 8 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-117 Mechanical Systems 2010 F2-MOV-25 F2-MOV-25, WASTE WASHWATER VALVE, FILTER 2, 24 INCH
BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-118 Mechanical Systems 2010 F2-MOV-26 FW-MOV-26, FILTER TO WASTE VALVE, FILTER 2, 12 INCH
BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-119 Mechanical Systems 2010 F3-MO-31 F3-MO-31, INFLUENT VALVE ACTUATOR, FILTER 3, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 11-Intake / LLPS WTM-Valves-12 Mechanical Systems 2010 LL-HOV-2 LL-HOV-2, 12 GATE VALVE, CLARIFIER RECYCLE, LLPS, WTP Valves Gate 17 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 14-Filters WTM-Valves-120 Mechanical Systems 2010 F3-MO-32 F3-MO-32, EFFLUENT VALVE ACTUATOR, FILTER 3, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-121 Mechanical Systems 2010 F3-MO-33 F3-MO-33, BACKWASH VALVE ACTUATOR, FILTER 3, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 4 32 Med-High
WTM 14-Filters WTM-Valves-122 Mechanical Systems 2010 F3-MO-34 F3-MO-34, AIR SCOUR VALVE ACTUATOR, FILTER 3, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-123 Mechanical Systems 2010 F3-MO-35 F3-MO-35, WASTE WASHWATER VALVE, FILTER 3, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-124 Mechanical Systems 2010 F3-MO-36 F3-MO-36, FILTER TO WASTE VALVE ACTUATOR, FILTER 3, FILTER GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-125 Mechanical Systems 2010 F3-MOV-31 F3-MOV-31, INFLUENT VALVE, FILTER 3, 18 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-126 Mechanical Systems 2010 F3-MOV-32 F3-MOV-32, EFFLUENT VALVE, FILTER 3, 18 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-127 Mechanical Systems 2010 F3-MOV-33 F3-MOV-33, BACKWASH VALVE, FILTER 3, 24 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-128 Mechanical Systems 2010 F3-MOV-34 F3-MOV-34, AIR SCOUR VALVE, FILTER 3, 8 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-129 Mechanical Systems 2010 F3-MOV-35 F3-MOV-35, WASTE WASHWATER VALVE, FILTER 3, 24 INCH
BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 11-Intake / LLPS WTM-Valves-13 Mechanical Systems 2010 LL-MO-1 LL-MO-1, ACTUATOR, PUMP 1 EFFLUENT VALVE, LLPS, WTP Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 14-Filters WTM-Valves-130 Mechanical Systems 2010 F3-MOV-36 F3-MOV-36, FILTER TO WASTE VALVE, FILTER 3, 12 INCH
BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-131 Mechanical Systems 2010 F4-MO-41 F4-MO-41, INFLUENT VALVE ACTUATOR, FILTER 4, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-132 Mechanical Systems 2010 F4-MO-42 F4-MO-42, EFFLUENT VALVE ACTUATOR, FILTER 4, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-133 Mechanical Systems 2010 F4-MO-43 F4-MO-43, BACKWASH VALVE ACTUATOR, FILTER 4, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 4 32 Med-High

Page 17 of 24 ends

Clity of Fairfield
Utility Master Plan Page 689 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 14-Filters WTM-Valves-134 Mechanical Systems 2010 F4-MO-44 F4-MO-44, AIR SCOUR VALVE ACTUATOR, FILTER 4, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-135 Mechanical Systems 2010 F4-MO-45 F4-MO-45, WASTE WASHWATER VALVE ACTUATOR, FILTER 4,
FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-136 Mechanical Systems 2010 F4-MO-46 F4-MO-46, FILTER TO WASTE VALVE ACTUATOR, FILTER 4, FILTER GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-137 Mechanical Systems 2010 F4-MOV-41 F4-MOV-41, INFLUENT VALVE, FILTER 4, 16 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-138 Mechanical Systems 2010 F4-MOV-42 F4-MOV-42, EFFLUENT VALVE, FILTER 4, 18 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-139 Mechanical Systems 2010 F4-MOV-43 F4-MOV-43, BACKWASH VALVE, FILTER 4, 24 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 11-Intake / LLPS WTM-Valves-14 Mechanical Systems 2010 LL-MO-2 LL-MO-2, ACTUATOR, PUMP 2 EFFLUENT BUTTERFLY VALVE,
LLPS, WTP Valves Butterfly 12
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 14-Filters WTM-Valves-140 Mechanical Systems 2010 F4-MOV-44 F4-MOV-44, AIR SCOUR VALVE, FILTER 4, 8 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-141 Mechanical Systems 2010 F4-MOV-45 F4-MOV-45. WASTE WASHWATER VALVE, FILTER 4, 24 INCH
BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-142 Mechanical Systems 2010 F4-MOV-46 F4-MOV-46, FILTER TO WASTE VALVE, FILTER 4, 12 INCH
BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-143 Mechanical Systems 2010 F5-MO-51 F5-MO-51, INFLUENT VALVE ACTUATOR, FILTER 5, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-144 Mechanical Systems 2010 F5-MO-52 F5-MO-52, EFFLUENT VALVE ACTUATOR, FILTER 5, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-145 Mechanical Systems 2010 F5-MO-53 F5-MO-53, BACKWASH VALVE ACTUATOR, FILTER 5, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 4 32 Med-High
WTM 14-Filters WTM-Valves-146 Mechanical Systems 2010 F5-MO-54 F5-MO-54, AIR SCOUR VALVE ACTUATOR, FILTER 5, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-147 Mechanical Systems 2010 F5-MO-55 F5-MO-55, WASTE WASHWATER VALVE ACTUATOR, FILTER 5,
FILTER GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-148 Mechanical Systems 2010 F5-MO-56 F5-MO-56, FILTER TO WASTE VALVE ACTUATOR, FILTER 5, FILTER GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-149 Mechanical Systems 2010 f5-MOV-51 F5-MOV-51, INFLUENT VALVE, FILTER 5, 16 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 11-Intake / LLPS WTM-Valves-15 Mechanical Systems 2010 LL-MO-3 LL-MO-3, ACTUATOR, PUMP 3 EFFLUENT BUTTERFLY VALVE,
LLPS, WTP Valves Butterfly 12
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 14-Filters WTM-Valves-150 Mechanical Systems 2010 F5-MOV-52 F5-MOV-52, EFFLUENT VALVE, FILTER 5, 18 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-151 Mechanical Systems 2010 F5-MOV-53 F5-MOV-53, BACKWASH VALVE, FILTER 5, 24 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-152 Mechanical Systems 2010 F5-MOV-54 F5-MOV-54, AIR SCOUR VALVE, FILTER 5, 8 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-153 Mechanical Systems 2010 F5-MOV-55 F5-MOV-55, WASTE WASHWATER VALVE, FILTER 5, 24 INCH
BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-154 Mechanical Systems 2010 F5-MOV-56 F5-MOV-56, FILTER TO WASTE VALVE, FILTER 5, 12 INCH
BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-155 Mechanical Systems 2010 F6-MO-61 F6-MO-61, FILTER 6 ACTUATOR, INFLUENT VALVE, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-156 Mechanical Systems 2010 F6-MO-62 F6-MO-62, FILTER 6 ACTUATOR, EFFLUENT VALVE, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-157 Mechanical Systems 2010 F6-MO-63 F6-MO-63, FILTER 6 ACTUATOR, BACKWASH VALVE, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 4 32 Med-High
WTM 14-Filters WTM-Valves-158 Mechanical Systems 2010 F6-MO-64 F6-MO-64, HC-664, FILTER 6 ACTUATOR, AIR SCOUR VALVE,
FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-159 Mechanical Systems 2010 F6-MO-65 FILTER 6 ACTUATOR, WASTE WASHWATER VALVE, FILTER DECK,
WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 11-Intake / LLPS WTM-Valves-16 Mechanical Systems 2010 LL-MO-4 LL-MO-4, ACTUATOR, PUMP 4 EFFLUENT BUTTERFLY VALVE,
LLPS, WTP Valves Butterfly 12
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 14-Filters WTM-Valves-160 Mechanical Systems 2010 F6-MO-66 F6-MO-66, FILTER 6 ACTUATOR, FILTER TO WASTE VALVE, FILTER GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-161 Mechanical Systems 2010 F6-MOV-61 F6-MOV-61, VALVE, FILTER 6 INFLUENT, 16 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-162 Mechanical Systems 2010 F6-MOV-62 F6-MOV-62, VALVE, FILTER 6 EFFLUENT, 18 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-163 Mechanical Systems 2010 F6-MOV-63 VALVE, FILTER 6 BACKWASH, 24 INCH BUTTERFLY, FILTER
GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-164 Mechanical Systems 2010 F6-MOV-64 F6-M0V-64, VALVE, FILTER 6 AIR SCOUR, 8 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-165 Mechanical Systems 2010 F6-MOV-65 F6-MOV-65, VALVE, FILTER 6 WASTE WASHWATER, 24 INCH
BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-166 Mechanical Systems 2010 F6-MOV-66 F6-MOV-66, VALVE, FILTER 6 FILTER TO WASTE, 12 INCH
BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-167 Mechanical Systems 2010 F7-MO-71 F7-MO-71, FILTER 7 ACTUATOR, INFLUENT VALVE, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-168 Mechanical Systems 2010 F7-MO-72 F7-MO-72, FILTER 7 ACTUATOR, EFFLUENT VALVE, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-169 Mechanical Systems 2010 F7-MO-73 BW valve Actuator Valves Other (Valves) 12 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 4 32 Med-High
WTM 11-Intake / LLPS WTM-Valves-17 Mechanical Systems 2010 LL-MOV-1 LL-MOV-1, PUMP 1, 24 EFFLUENT BUTTERFLY VALVE, LLPS, WTP Valves Butterfly 12 Increased
Maintenance Reduced Capacity/Pressure 2 6 30 Med-High

Page 18 of 24 ends

Clity of Fairfield
Utility Master Plan Page 690 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 14-Filters WTM-Valves-170 Mechanical Systems 2010 F7-MO-74 F7-MO-74, HC-674, FILTER 7 ACTUATOR, AIR SCOUR VALVE,
FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-171 Mechanical Systems 2010 F7-MO-75 F7-MO-75, FILTER 7 ACTUATOR, WASTE WASHWATER VALVE,
FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-172 Mechanical Systems 2010 F7-MO-76 F7-MO-76, FILTER 7 ACTUATOR, FILTER TO WASTE VALVE, FILTER GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-173 Mechanical Systems 2010 F7-MOV-71 F7-MOV-71, VALVE, FILTER 7 INFLUENT, 16 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-174 Mechanical Systems 2010 F7-MOV-72 F7-MOV-72, VALVE, FILTER 7 EFFLUENT, 18 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-175 Mechanical Systems 2010 F7-MOV-73 F7-MOV-73, VALVE, FILTER 7 BACKWASH, 24 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-176 Mechanical Systems 2010 F7-MOV-74 F7-MOV-74, VALVE, FILTER 7 AIR SCOUR, 8 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-177 Mechanical Systems 2010 F7-MOV-75 F7-MOV-75, VALVE, FILTER 7 WASTE WASHWATER, 24 INCH
BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-178 Mechanical Systems 2010 F7-MOV-76 F7-MOV-76, VALVE, FILTER 7 FILTER TO WASTE, 12 INCH
BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-179 Mechanical Systems 2010 F8-MO-81 F8-MO-81, FILTER 8 ACTUATOR, INFLUENT VALVE, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 11-Intake / LLPS WTM-Valves-18 Mechanical Systems 2010 LL-MOV-2 LL-MOV-2, PUMP 2, 24 EFFLUENT BUTTERFLY VALVE, LLPS, WTP Valves Butterfly 12 Increased
Maintenance Reduced Capacity/Pressure 2 6 30 Med-High
WTM 14-Filters WTM-Valves-180 Mechanical Systems 2010 F8-MO-82 F8-MO-82, FILTER 8 ACTUATOR, EFFLUENT VALVE, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-181 Mechanical Systems 2010 F8-MO-83 F8-MO-83, FILTER 8 ACTUATOR, BACKWASH VALVE, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 4 32 Med-High
WTM 14-Filters WTM-Valves-182 Mechanical Systems 2010 F8-MO-84 F8-MO-84, HC-684, FILTER 8 ACTUATOR, AIR SCOUR VALVE,
FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-183 Mechanical Systems 2010 F8-MO-85 F8-MO-85, FILTER 8 ACTUATOR, WASTE WASHWATER VALVE,
FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-184 Mechanical Systems 2010 F8-MO-86 F8-MO-86, FILTER 8 ACTUATOR, FILTER TO WASTE VALVE, FILTER GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-185 Mechanical Systems 2010 F8-MOV-81 F8-MOV-81, VALVE, FILTER 8 INFLUENT, 16 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-186 Mechanical Systems 2010 F8-MOV-82 F8-MOV-82, VALVE, FILTER 8 EFFLUENT, 18 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-187 Mechanical Systems 2010 F8-MOV-83 F8-MOV-83, VALVE, FILTER 8 BACKWASH, 24 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-188 Mechanical Systems 2010 F8-MOV-84 F8-MOV-84, VALVE, FILTER 8 AIR SCOUR, 8 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-189 Mechanical Systems 2010 F8-MOV-85 F8-MOV-85, VALVE, FILTER 8 WASTE WASHWATER, 24 INCH
BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 11-Intake / LLPS WTM-Valves-19 Mechanical Systems 2010 LL-MOV-3 LL-MOV-3, PUMP 3, 24 EFFLUENT BUTTERFLY VALVE, LLPS, WTP Valves Butterfly 12 Increased
Maintenance Reduced Capacity/Pressure 2 6 30 Med-High
WTM 14-Filters WTM-Valves-190 Mechanical Systems 2010 F8-MOV-86 F8-MOV-86, VALVE, FILTER 8 FILTER TO WASTE, 12 INCH, FILTER GALLERY, WTP Valves Other (Valves) 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-191 Mechanical Systems 2010 F9-MO-91 F9-MO-91, FILTER 9 ACTUATOR, INFLUENT VALVE, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-192 Mechanical Systems 2010 F9-MO-92 Filter 9 EFF Valve Actuator Valves Other (Valves) 12 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-193 Mechanical Systems 2010 F9-MO-93 F9-MO-93, FILTER 9 ACTUATOR, BACKWASH VALVE, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 4 32 Med-High
WTM 14-Filters WTM-Valves-194 Mechanical Systems 2010 F9-MO-94 F9-MO-94, HC-694, FILTER 9 ACTUATOR, AIR SCOUR VALVE,
FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-195 Mechanical Systems 2010 F9-MO-95 F9-MO-95, FILTER 9 ACTUATOR, WASTE WASHWATER VALVE,
FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-196 Mechanical Systems 2010 F9-MO-96 F9-MO-96, FILTER 9 ACTUATOR, FILTER TO WASTE VALVE, FILTER GALLERY,WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-197 Mechanical Systems 2010 F9-MOV-91 F9-MOV-91, VALVE, FILTER 9 INFLUENT, 16 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-198 Mechanical Systems 2010 F9-MOV-92 F9-MOV-92, VALVE, FILTER 9 EFFLUENT, 18 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-199 Mechanical Systems 2010 F9-MOV-93 F9-M0V-93, VALVE, FILTER 9 BACKWASH, 24 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 11-Intake / LLPS WTM-Valves-2 Mechanical Systems 1974 LL-HOV-1 LL-HOV-1, 16 GATE VALVE, HEADER EFFLUENT RECYCLE, LLPS, WTP Valves Gate -19 Rehabilitation Reduced Capacity/Pressure 2 6 36 Med-High WTM 11-Intake / LLPS WTM-Valves-20 Mechanical Systems 2010 LL-MOV-4 LL-MOV-4, PUMP 4, 18 EFFLUENT BUTTERFLY VAVLE, LLPS, WTP Valves Butterfly 12 Increased
Maintenance Reduced Capacity/Pressure 2 6 30 Med-High
WTM 14-Filters WTM-Valves-200 Mechanical Systems 2010 F9-MOV-94 F9-MOV-94, VALVE, FILTER 9 AIR SCOUR, 8 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-201 Mechanical Systems 2010 F9-MOV-95 F9-MOV-95, VALVE, FILTER 9 WASTE WASHWATER, 24 INCH
BUTTERFLY, FILTER DECK, WTP[ Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-202 Mechanical Systems 2010 F9-MOV-96 F9-MOV-96, VALVE, FILTER 9 FILTER TO WASTE, 12 INCH
BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-203 Mechanical Systems 2010 F-CKV-10 F-CKV-10, 10 CHECK VALVE, FILTER TO WASTE PUMP 1
DISCHARGE, FILTER GALLERY, WTP Valves Check Valve 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 14-Filters WTM-Valves-204 Mechanical Systems 2010 F-CKV-20 F-CKV-20, 10 CHECK VALVE, FILTER TO WASTE PUMP 2
DISCHARGE, FILTER GALLERY, WTP Valves Check Valve 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 14-Filters WTM-Valves-205 Mechanical Systems 2010 FDV-1 FDV-1, DRAIN VALVE, CONDITIONED/APPLIED WATER CHANNEL,

MANUAL, FILTER GALLERY, ABOVE NORTH FILTERS CFE PIPE,
WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 32 Med-Low

Page 19 of 24 ends

Clity of Fairfield
Utility Master Plan Page 691 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 14-Filters WTM-Valves-206 Mechanical Systems 2010 F-HOV-10 F-HOV-10, 8 MANUAL BUTTERFLY VALVE, FILTER TO WASTE
PUMP 1 SUCTION, FILTER GALLERY, WTP Valves Butterfly 12 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 14-Filters WTM-Valves-207 Mechanical Systems 2010 F-HOV-11 F-HOV-11, 10 MANUAL BUTTERFLY VALVE, FILTER TO WASTE
PUMP 1 DISCHARGE, FILTER GALLERY, WTP Valves Butterfly 12 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 14-Filters WTM-Valves-208 Mechanical Systems 2010 F-HOV-20 F-HOV-20, 8 MANUAL BUTTERFLY VALVE, FILTER TO WASTE
PUMP 2 SUCTION, FILTER GALLERY, WTP Valves Butterfly 12 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 14-Filters WTM-Valves-209 Mechanical Systems 2010 F-HOV-21 F-HOV-21, 10 MANUAL BUTTERFLY VALVE, FILTER TO WASTE
PUMP 2 DISCHARGE, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 5 30 Medium
WTM 12-Pretreatment WTM-Valves-21 Mechanical Systems 2010 2181 AF-HOV-242, VALVE, EFF SAND PUMP 1, WEST ACTIFLO, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 14-Filters WTM-Valves-210 Mechanical Systems 2010 F-HOV-30 F-HOV-30, 12 MANUAL BUTTERFLY VALVE, FILTER TO WASTE
ISOLATION TO EQ BASIN, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 5 30 Medium
WTM 14-Filters WTM-Valves-211 Mechanical Systems 2010 F-HOV-31 F-HOV-31, 12 MANUAL BUTTERFLY VALVE, FILTER TO WASTE
ISOLATION TO APPLIED WATER CONDUIT, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 5 30 Medium
WTM 14-Filters WTM-Valves-212 Mechanical Systems 2010 FW-MO-26 FW-MO-26, FILTER TO WASTE VALVE ACTUATOR, FILTER 2,
FILTER GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 15-HLPS WTM-Valves-213 Mechanical Systems 1974 HL-MOV-89 48 DISTRIBUTION VALVE, Valves Other (Valves) -24 Replace or Run to
Failure Process/Facility Cannot Operate Without 5 9 63 High WTM 15-HLPS WTM-Valves-214 Mechanical Systems 1974 HL-MOV-V-80 HL-MOV-V-80, VALVE, 14 BUTTERFLY, PUMP 1 DISCHARGE,
HLPS, WTP Valves Butterfly -24
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 6 42 Med-High
WTM 15-HLPS WTM-Valves-215 Mechanical Systems 1974 HL-MOV-V-82 HL-MOV-V-82, VALVE, 20 BUTTERFLY, PUMP 2 DISCHARGE,
HLPS, WTP Valves Butterfly -24
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 6 42 Med-High
WTM 15-HLPS WTM-Valves-216 Mechanical Systems 1974 HLPS-V-79 HLPS-V-79, 14 CHECK VALVE, PUMP 1 DISCHARGE, HLPS, WTP Valves Check Valve -24 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 15-HLPS WTM-Valves-217 Mechanical Systems 1974 HLPS-V-81 HLPS-V-81, VALVE, 20 CHECK, PUMP 2 DISCHARGE, HLPS, WTP Valves Check Valve -24 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 15-HLPS WTM-Valves-218 Mechanical Systems 1974 MOV-V-90 HIGH SERVICE VALVE, WATERMAN RESERVOIR CONNECTION,30
BUTTERFLY Valves Butterfly -24
Replace or Run to
Failure Reduced Capacity/Pressure 5 8 56 High
WTM 15-HLPS WTM-Valves-219 Mechanical Systems 1986 HL-CKV-4 HL-CKV-4, VALVE, 24 CHECK, PUMP 4 DISCHARGE, HLPS, WTP Valves Check Valve -12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 4 24 Med-Low
WTM 12-Pretreatment WTM-Valves-22 Mechanical Systems 2010 2183 AF-HOV-243, VALVE, EFF SAND PUMP 2, WEST ACTIFLO, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 15-HLPS WTM-Valves-220 Mechanical Systems 1986 HL-MOV-4 HL-MOV-4, VALVE, 24 BUTTERFLY, PUMP 4 DISCHARGE, HLPS,
WTP Valves Butterfly -12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 6 36 Med-High
WTM 15-HLPS WTM-Valves-221 Mechanical Systems 1986 HL-MOV-V-84 HL-MOV-V-84, VALVE, 24 BUTTERFLY, PUMP 3 DISCHARGE,
HLPS, WTP Valves Butterfly -12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 6 36 Med-High
WTM 15-HLPS WTM-Valves-222 Mechanical Systems 1986 HLPS-V-85 HLPS-V-85, VALVE, 24 CHECK, PUMP 3 DISCHARGE, HLPS, WTP Valves Check Valve -12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 4 24 Med-Low
WTM 15-HLPS WTM-Valves-223 Mechanical Systems 2010 HL-CKV-5 HL-CKV-5, VALVE, 24 CHECK, PUMP 5 DISCHARGE, HLPS, WTP Valves Check Valve 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 4 24 Med-Low
WTM 15-HLPS WTM-Valves-224 Mechanical Systems 2010 HL-MOV-5 HL-MOV-5, VALVE, 24 BUTTERFLY, PUMP 5 DISCHARGE, HLPS,
WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 2 6 36 Med-High
WTM 16-Chemicals WTM-Valves-225 Mechanical Systems 2010 CS-MOV-1 CS-MOV-1, HYPO TANK 1, MOV, METERING PUMP FEED VALVE,
SOUTH TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-226 Mechanical Systems 2010 CS-MOV-10

MOV, CATIONIC POLYMER TANK, FEED TO METERING PUMPS,
NORTH CHEM TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-227 Mechanical Systems 2010 CS-MOV-11 CS-MOV-11, MOV, MIX/TRANSFER PUMP, HYPO TANK 1, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-228 Mechanical Systems 2010 CS-MOV-13 MOV, MIX/TRANSFER PUMP, CAUSTIC TANK 1, SOUTH TANK
FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-229 Mechanical Systems 2010 CS-MOV-14 MOV, MIX/TRANSFER PUMP, CAUSTIC TANK 2, SOUTH TANK
FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 12-Pretreatment WTM-Valves-23 Mechanical Systems 2010 2184 AF-HOV-244, VALVE, EFF SAND PUMP 3, WEST ACTIFLO, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 16-Chemicals WTM-Valves-230 Mechanical Systems 2010 CS-MOV-15 MOV, MIX/TRANSFER PUMP, ACH TANK 1, NORTH TANK FARM,
WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-231 Mechanical Systems 2010 CS-MOV-16 MOV, MIX/TRANSFER PUMP, ALUM TANK 2, NORTH TANK
FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-232 Mechanical Systems 2010 CS-MOV-17 ISOLATION VALVE, MIX/TRANSFER PUMP, ALUM TANK 3, NORTH
TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-233 Mechanical Systems 2010 CS-MOV-2 CS-MOV-2, HYPO TANK 2, MOV, METERING PUMP FEED VALVE,
SOUTH TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-234 Mechanical Systems 2010 CS-MOV-3 MOV, CAUSTIC TANK 1, MOV, METERING PUMP FEED VALVE,
SOUTH TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-235 Mechanical Systems 2010 CS-MOV-4 MOV, CAUSTIC TANK 2, METERING PUMP FEED VALVE, SOUTH
TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-236 Mechanical Systems 2010 CS-MOV-5 MOV, ACH TANK 1, METERING PUMP FEED VALVE, NORTH TANK
FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-237 Mechanical Systems 2010 CS-MOV-6 ALUM TANK 2, MOV, METERING PUMP FEED VALVE, NORTH
TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-238 Mechanical Systems 2010 CS-MOV-7 ALUM TANK 3, MOV, METERING PUMP FEED VALVE, NORTH
TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-239 Mechanical Systems 2010 CS-MOV-8 MOV, METERING PUMP FEED VALVE, NORTH TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 12-Pretreatment WTM-Valves-24 Mechanical Systems 2010 AF-HOV-12 VALVE, EAST ACTIFLO COAG DRAIN, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 16-Chemicals WTM-Valves-240 Mechanical Systems 2010 CS-MOV-9 MOV, FLUORIDE TANK 2, METERING PUMP FEED VALVE, NORTH
TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-241 Mechanical Systems 2010 FCV-903 FCV-903, FILL CONTROL VALVE, DRY ANIONIC FLOC AID POLY, CHEM BLDG, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low

Page 20 of 24 ends

Clity of Fairfield
Utility Master Plan Page 692 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 16-Chemicals WTM-Valves-242 Mechanical Systems 2010 FCV-903x FCV-903x, FLOW CONTROL VALVE, MIX TANK UTILITY WATER,
SOUTH POLYBLEND, CHEM BLDG, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-243 Mechanical Systems 2010 FCV-944 FCV-944, FLOW CONTROL VALVE, MIX TANK UTILITY WATER,
NORTH POLYBLEND, CHEM BLDG, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-244 Mechanical Systems 2010 FCV-CO2 FCV-CO2, CO2 FLOW CONTROL VALVE WITH POSITION
INDICATOR AND TRANSMITTER, CO2 CONTROL CABINET, CO2
STORAGE AREA, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 16-Chemicals WTM-Valves-245 Mechanical Systems 2010 SHC-MOV-12 SHC-MOV-12, MOV to MIX/TRANSFER PUMP, HYPO TANK 2,
SOUTH CHEM TANK FARM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 4 16 Med-Low WTM 17-Ozone Generation WTM-Valves-246 Mechanical Systems 1990 OG-MOV-11 OG-MOV-11, VALVE, 3 BUTTERFLY, OZONE GENERATOR 1
OXYGEN SUPPLY, OZONE GENERATOR ROOM, WTP Valves Butterfly -8 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 17-Ozone Generation WTM-Valves-247 Mechanical Systems 1990 OG-MOV-12 OZONE GAS EFFLUENT,VALVE ACTUATOR OZONE GENERATOR 1,
OZONE GENERATOR ROOM, WTP Valves Other (Valves) -8
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 17-Ozone Generation WTM-Valves-249 Mechanical Systems 1990 OG-MOV-21 OG-MOV-21, VALVE, 3 BUTTERFLY, OZONE GENERATOR 2
OXYGEN SUPPLY, OZONE GENERATOR ROOM, WTP Valves Butterfly -8 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 12-Pretreatment WTM-Valves-25 Mechanical Systems 2010 AF-HOV-13 VALVE, EAST ACTIFLO MATURATION DRAIN, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 17-Ozone Generation WTM-Valves-250 Mechanical Systems 1990 OG-MOV-22 OG-MOV-22, VALVE, 2.5 BUTTERFLY, OZONE GENERATOR 2 GAS
EFFLUENT, OZONE GENERATOR ROOM, WTP Valves Butterfly -8 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 17-Ozone Generation WTM-Valves-251 Mechanical Systems 1990 OG-MOV-23 OG-MOV-23, VALVE, 2 BUTTERFLY, OZONE GENERATOR 2
COOLING SUPPLY, OZONE GENERATOR ROOM, WTP Valves Butterfly -8 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 2 4 28 Med-Low
WTM 17-Ozone Generation WTM-Valves-252 Mechanical Systems 2010 OG-MOV-1 OG-MOV-1, OZONE EFFLUENT METERING VALVE, OZONE GAS TO
OZONE CONTACTORS, OZONE GENERATOR ROOM, WTP Valves Other (Valves) 12 No Action Required Reduced Efficiency 1 5 20 Medium WTM 17-Ozone Generation WTM-Valves-253 Mechanical Systems 2010 OG-MOV-31 OG-MOV-31, VALVE, 3 BUTTERFLY, OZONE GENERATOR 3
OXYGEN SUPPLY, OZONE GENERATOR ROOM, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 4 24 Med-Low
WTM 17-Ozone Generation WTM-Valves-254 Mechanical Systems 2010 OG-MOV-32 OG-MOV-32, VALVE, 2.5 BUTTERFLY, OZONE GENERATOR 3 GAS
EFFLUENT, OZONE GENERATOR ROOM, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 4 24 Med-Low
WTM 17-Ozone Generation WTM-Valves-255 Mechanical Systems 2010 OG-MOV-33 OG-MOV-33, VALVE, 2 BUTTERFLY, OZONE GENERATOR 3
COOLING WATER SUPPLY, OZONE GENERATOR ROOM, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 2 4 24 Med-Low
WTM 18-EQ Basin + WW PS WTM-Valves-256 Mechanical Systems 2010 EB-HOV-19 CLARIFIER DRAIN TO EQ BASIN 1 VALVE , Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 18-EQ Basin + WW PS WTM-Valves-257 Mechanical Systems 2010 EB-HOV-20 CLARIFIER DRAIN TO EQ BASIN 2 MANUAL VALVE, Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 18-EQ Basin + WW PS WTM-Valves-258 Mechanical Systems 2010 EB-MOV-1 EQ BASIN 1 INFLUENT MOV, Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 18-EQ Basin + WW PS WTM-Valves-259 Mechanical Systems 2010 EB-MOV-2 EQ BASIN 2 INF MOV, Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 12-Pretreatment WTM-Valves-26 Mechanical Systems 2010 AF-HOV-14 VALVE, INF SAND PUMP 1, EAST ACTIFLO, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 18-EQ Basin + WW PS WTM-Valves-260 Mechanical Systems 2010 WR-HOV-10 ACTIFLO BASIN DRAIN MANUAL VALVE, Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 18-EQ Basin + WW PS WTM-Valves-261 Mechanical Systems 2010 WR-HOV-13 FLOW METER OUT VALVE CLARIFIER DECANT, RPS, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 18-EQ Basin + WW PS WTM-Valves-262 Mechanical Systems 2010 WR-HOV-9 ACTIFLO BASIN DRAIN MANUAL VALVE, Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 18-EQ Basin + WW PS WTM-Valves-263 Mechanical Systems 2010 WR-MOV-3 EQ BASIN 1 DECANT VALVE, 8 BUTTERFLY Valves Butterfly 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 18-EQ Basin + WW PS WTM-Valves-264 Mechanical Systems 2010 WR-MOV-4 EQ BASIN 2 DECANT VALVE, 8 BUTTERFLY Valves Butterfly 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 18-EQ Basin + WW PS WTM-Valves-265 Mechanical Systems 2010 WR-MOV-5 EQ BASIN 1 SLUDGE EFFLUENT VALVE, 10 ECCENTRIC PLUG, Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 18-EQ Basin + WW PS WTM-Valves-266 Mechanical Systems 2010 WR-MOV-6 EQ BASIN 2 SLUDGE EFFLUENT VALVE, 10 ECCENTRIC PLUG, Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-267 Mechanical Systems 2010 SL-MOV-1 INFLUENT VALVE LAGOON 1, 12 PLUG, Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-268 Mechanical Systems 2010 SL-MOV-2 INFLUENT VALVE LAGOON 2, 12 PLUG, Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-269 Mechanical Systems 2010 SL-MOV-3 INFLUENT VALVE LAGOON 3, 12 PLUG, Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 4 20 Med-Low
WTM 12-Pretreatment WTM-Valves-27 Mechanical Systems 2010 AF-HOV-142 VALVE, EFF SAND PUMP 1 EAST ACTIFLO, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-270 Mechanical Systems 2010 WR-CKV-1 DECANT PUMP 1 DISCHARGE CHECK VALVE, RPS, WTP Valves Check Valve 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-271 Mechanical Systems 2010 WR-CKV-2 DECANT PUMP 2 DISCHARGE CHECK VALVE, RPS, WTP Valves Check Valve 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-272 Mechanical Systems 2010 WR-CKV-3 SLUDGE PUMP 1 DISCHARGE CHECK VALVE, RPS, WTP Valves Check Valve 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-273 Mechanical Systems 2010 WR-CKV-4 SLUDGE PUMP 2 DISCHARGE CHECK VALVE, RPS, WTP Valves Check Valve 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-274 Mechanical Systems 2010 WR-HOV-1 DECANT PUMP 1 SUCTION MANUAL VALVE, 8 BUTTERFLY, RPS,
WTP Valves Butterfly 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-275 Mechanical Systems 2010 WR-HOV-11 CLARIFIER DECANT VALVE, 12 BUTTERFLY, RPS, WTP WR-HOV11, VALVE, PROCESS RECYCLE/FLOW METER IN, Valves Butterfly 12 No Action RequiredLack of Redundancy/Potential Reduced Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-276 Mechanical Systems 2010 WR-HOV-12 CLARIFIER DECANT FLOW METER BYPASS VALVE, RPS, 12
BUTTERFLY Valves Butterfly 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-277 Mechanical Systems 2010 WR-HOV-2 DECANT PUMP 2 SUCTION VALVE, Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-278 Mechanical Systems 2010 WR-HOV-3 SLUDGE PUMP 1 SUCTION VALVE, 10 ECCENTRIC PLUG Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low

Page 21 of 24 ends

Clity of Fairfield
Utility Master Plan Page 693 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-279 Mechanical Systems 2010 WR-HOV-4 SLUDGE PUMP 2 SUCTION,VALVE, 10 ECCENTRIC PLUG Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 12-Pretreatment WTM-Valves-28 Mechanical Systems 2010 AF-HOV-143 VALVE, EFF SAND PUMP 2 EAST ACTIFLO, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-280 Mechanical Systems 2010 WR-HOV-5 DECANT PUMP 1 DISCHARGE VALVE, 8 BUTTERFLY Valves Butterfly 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-281 Mechanical Systems 2010 WR-HOV-6 DECANT PUMP 2 DISCHARGE, VALVE 8 BUTTERFLY Valves Butterfly 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-282 Mechanical Systems 2010 WR-HOV-7 SLUDGE PUMP 1 DISCHARGE VALVE, 8 ECCENTRIC PLUG, Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-283 Mechanical Systems 2010 WR-HOV-8 SLUDGE PUMP 2 DISCHARGE,8 ECCENTRIC PLUG, Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 19-Sludge Clarifiers and Lagoons WTM-Valves-284 Mechanical Systems 2010 WR-MOV-7 SLUDGE TO LAGOON VALVE, 8 ECCENTRIC PLUG Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 21-Blowers / Z3PS WTM-Valves-285 Mechanical Systems 2010 FS-CKV-1 FS-CKV-1, DOUBLE DOOR CHECK VALVE, FILTER AIR SCOUR
BLOWER 1 DISCH, BLOWER BLDG, WTP Valves Check Valve 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 21-Blowers / Z3PS WTM-Valves-286 Mechanical Systems 2010 FS-CKV-2 FS-CKV-2, DOUBLE DOOR CHECK VALVE, FILTER AIR SCOUR
BLOWER 2 DISCH, BLOWER BLDG, WTP Valves Check Valve 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 21-Blowers / Z3PS WTM-Valves-287 Mechanical Systems 2010 FS-HOV-1 FS-HOV-1, BUTTERFLY VALVE, FILTER AIR SCOUR BLOWER #1
DISCH ISO, BLOWER BLDG, WTP Valves Butterfly 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 21-Blowers / Z3PS WTM-Valves-288 Mechanical Systems 2010 FS-HOV-2 FS-HOV-2, BUTTERFLY VALVE, FILTER AIR SCOUR BLOWER #2
DISCH ISO, BLOWER BLDG, WTP Valves Butterfly 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 21-Blowers / Z3PS WTM-Valves-289 Mechanical Systems 2010 FS-MOV-2 FS-MOV-2, VALVE, MOTOR OPERATED, FILTER AIR SCOUR
BLOWER EXHAUST, BLOWER BLDG, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 4 16 Med-Low
WTM 12-Pretreatment WTM-Valves-29 Mechanical Systems 2010 AF-HOV-144 VALVE, EFF SAND PUMP 3, EAST ACTIFLO, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 21-Blowers / Z3PS WTM-Valves-290 Mechanical Systems 2010 FS-RLF-1 FS-RLF-1, RELIEF VALVE, BLOWER 1, FILTER AIR SCOUR
DISCHARGE LINE, BLOWER BLDG, WTP Valves Air Valve 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 21-Blowers / Z3PS WTM-Valves-291 Mechanical Systems 2010 FS-RLF-2 FS-RLF-2, RELIEF VALVE, BLOWER 2, FILTER AIR SCOUR
DISCHARGE LINE, BLOWER BLDG, WTP Valves Air Valve 17 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 00-Misc Systems WTM-Valves-292 Mechanical Systems 2010 FM-HOV-1 FM-HOV-1, 36 BFV, INFLUENT FLOW METER ISO VALVE, FMV,
WTP Valves Other (Valves) 12 Rehabilitation
Process/Facility Operates Normally
Without 2 5 30 Medium
WTM 00-Misc Systems WTM-Valves-293 Mechanical Systems 2010 FM-HOV-2 FM-HOV-2, 42 BFV, INFLUENT FLOW METER ISO VALVE, FMV,
WTP Valves Other (Valves) 12 Rehabilitation
Process/Facility Operates Normally
Without 2 5 30 Medium
WTM 11-Intake / LLPS WTM-Valves-3 Mechanical Systems 1974 LL-HOV-10 LL-HOV-10, 42 BUTTERFLY VALVE, DISCHARGE HEADER, LLPS,
WTP Valves Butterfly -24 Rehabilitation Reduced Capacity/Pressure 2 6 42 Med-High WTM 12-Pretreatment WTM-Valves-30 Mechanical Systems 2010 AF-HOV-16 VALVE, INF SAND PUMP 2, EAST ACTIFLO, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-31 Mechanical Systems 2010 AF-HOV-18 VALVE, INF SAND PUMP 3, EAST ACTIFLO, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-32 Mechanical Systems 2010 FM-CKV-11 FM-CKV-11, FLASH MIX PUMP 1 DISCHARGE CHECK VALVE, OPS
BASEMENT, WTP Valves Check Valve 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-33 Mechanical Systems 2010 FM-CKV-21 FM-CKV-21, FLASH MIX PUMP 2 DISCHARGE CHECK VALVE, OPS
BASEMENT, WTP Valves Check Valve 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-34 Mechanical Systems 2010 FM-HOV-11 FM-HOV-11, FLASH MIX PUMP 1 SUCTION VALVE, OPS
BASEMENT, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-35 Mechanical Systems 2010 FM-HOV-12 FM-HOV-12, FLASH MIX PUMP 1 DISCHARGE VALVE, OPS
BASEMENT, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-36 Mechanical Systems 2010 FM-HOV-12A FM-HOV-12A, FLASH MIX PUMP 2 SUCTION VALVE, OPS
BASEMENT, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-37 Mechanical Systems 2010 FM-HOV-22 FM-HOV-22, FLASH MIX PUMP 2 DISCHARGE VALVE, OPS
BASEMENT, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-38 Mechanical Systems 2010 AF-HOV-22 AF-HOV-22, VALVE, PLUG, 8 INCH, WEST ACTIFLO COAG DRAIN, WTP Valves Other (Valves) 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-39 Mechanical Systems 2010 AF-HOV-23 AF-HOV-23, VALVE, PLUG, 8 INCH, WEST ACTIFLO MAT DRAIN, WTP Valves Other (Valves) 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 11-Intake / LLPS WTM-Valves-4 Mechanical Systems 1985 ARV-LL-3 ARV-LL-3, AIR RELIEF VALVE, LL PUMP 3 DISCHARGE, LLPS, WTP Valves Air Valve -8 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 12-Pretreatment WTM-Valves-40 Mechanical Systems 2010 AF-HOV-24 VALVE, PLUG, 6 INCH, INF SAND PUMP 1, WEST ACTIFLO Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-41 Mechanical Systems 2010 AF-HOV-26 VALVE, PLUG, 6 INCH, INF SAND PUMP 2, WEST ACTIFLO, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 12-Pretreatment WTM-Valves-42 Mechanical Systems 2010 AF-MOV-11 VALVE, ACTIFLO EAST TRAIN INF 803, WTP Valves Other (Valves) 12 No Action Required Process/Facility Cannot Operate Without 3 9 36 High WTM 12-Pretreatment WTM-Valves-43 Mechanical Systems 2010 AF-MOV-12 VALVE, 42 INCH BUTTERFLY, EAST ACTIFLO EFF. WTP Valves Butterfly 12 No Action Required Process/Facility Cannot Operate Without 3 9 36 High WTM 12-Pretreatment WTM-Valves-44 Mechanical Systems 2010 AF-MOV-21 VALVE, 42 INCH BUTTERFLY, WEST ACTIFLO INF, WTP Valves Butterfly 12 No Action Required Process/Facility Cannot Operate Without 3 9 36 High WTM 12-Pretreatment WTM-Valves-45 Mechanical Systems 2010 AF-MOV-22 VALVE, 42 INCH BUTTERFLY, WEST ACTIFLO EFF, WTP Valves Butterfly 12 No Action Required Process/Facility Cannot Operate Without 3 9 36 High WTM 13-Ozone Contact + ICA WTM-Valves-46 Mechanical Systems 1990 OC-MO-31 OX-MO-31, INFLUENT VALVE ACTUATOR, OZONE BASIN 3,
OZONE CONTACTOR, WTP Valves Other (Valves) -8
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-47 Mechanical Systems 1990 OC-MO-32 EFFLUENT VALVE ACTUATOR, OZONE BASIN 3, OZONE
CONTACTOR, WTP Valves Other (Valves) -8
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-48 Mechanical Systems 1990 OC-MO-41 OC-MO-41, INFLUENT VALVE ACTUATOR, OZONE BASIN 4,
OZONE CONTACTOR, WTP Valves Other (Valves) -8
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-49 Mechanical Systems 1990 OC-MO-42 OC-MO-42, EFFLUENT VALVE ACTUATOR, OZONE BASIN 4,
OZONE CONTACTOR, WTP Valves Other (Valves) -8
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 11-Intake / LLPS WTM-Valves-5 Mechanical Systems 1985 ARV-LL-4 ARV-LL-4, AIR RELIEF VALVE, LL PUMP 4 DISCHARGE, LLPS, WTP Valves Air Valve -8 Rehabilitation Reduced Efficiency 2 4 24 Med-Low

Page 22 of 24 ends

Clity of Fairfield
Utility Master Plan Page 694 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 13-Ozone Contact + ICA WTM-Valves-50 Mechanical Systems 1990 OC-MOV-31 OX-MOV-31, INFLUENT VALVE, 30 INCH BUTTERFLY, OZONE
BASIN 3, WTP Valves Butterfly -8 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 3 4 16 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-51 Mechanical Systems 1990 OC-MOV-32 OC-MOV-32, EFFLUENT VALVE, 30 INCH BUTTERFLY, OZONE
BASIN 3, OZONE CONTACTOR, WTP Valves Butterfly -8 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 4 16 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-52 Mechanical Systems 1990 OC-MOV-41 OC-MOV-41, INFLUENT VALVE, 30 INCH BUTTERFLY, OZONE
BASIN 4, OZONE CONTACTOR, WTP Valves Butterfly -8 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 4 16 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-53 Mechanical Systems 1990 OC-MOV-42 OC-MOV-42, EFFLUENT VALVE, 30 INCH BUTTERFLY, OZONE
BASIN 4, OZONE CONTACTOR, WTP Valves Butterfly -8 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 4 16 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-54 Mechanical Systems 2010 OC-HOV-1 OC-HOV-1, VALVE, NE EFFLUENT CHANNEL DRAIN, OZONE
CONTACTOR, WTP Valves Other (Valves) 12
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 4 3 15 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-55 Mechanical Systems 2010 OC-HOV-10 OC-HOV-10, VALVE, NW EFFLUENT CHANNEL DRAIN, OZONE
CONTACTOR, WTP Valves Other (Valves) 12
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 13-Ozone Contact + ICA WTM-Valves-56 Mechanical Systems 2010 OC-HOV-11 OC-HOV-11, VALVE, OC DRAIN SUMP DISCHARGE ISOLATION,
OZONE CONTACTOR, WTP Valves Other (Valves) 12
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 13-Ozone Contact + ICA WTM-Valves-57 Mechanical Systems 2010 OC-HOV-2 OC-HOV-2, VALVE, OZONE CONTACT BASIN 4 DRAIN, OZONE
CONTACTOR, WTP Valves Other (Valves) 12
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 13-Ozone Contact + ICA WTM-Valves-58 Mechanical Systems 2010 OC-HOV-3 OC-HOV-3, VALVE, SE EFFLUENT CHANNEL DRAIN, OZONE
CONTACTOR, WTP Valves Other (Valves) 12
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 13-Ozone Contact + ICA WTM-Valves-59 Mechanical Systems 2010 OC-HOV-4 OC-HOV-4, VALVE, BASIN 3 DRAIN, OZONE CONTACTOR, WTP Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 11-Intake / LLPS WTM-Valves-6 Mechanical Systems 2010 ARV-LL-1 ARV-LL-1, AIR RELIEF VALVE, LL PUMP 1 DISCHARGE, LLPS, WTP Valves Air Valve 17 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 13-Ozone Contact + ICA WTM-Valves-60 Mechanical Systems 2010 OC-HOV-5 OC-HOV-5, VALVE, SE INFLUENT CHANNEL DRAIN, OZONE
CONTACTOR, WTP Valves Other (Valves) 12
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 13-Ozone Contact + ICA WTM-Valves-61 Mechanical Systems 2010 OC-HOV-6 OC-HOV-6, VALVE, OZONE CONTACTOR
SAMPLE/INSTRUMENTATION GALLERY DRAIN, WTP Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 13-Ozone Contact + ICA WTM-Valves-62 Mechanical Systems 2010 OC-HOV-7 OC-HOV-7, VALVE, SW INFLUENT CHANNEL DRAIN, OZONE
CONTACTOR, WTP Valves Other (Valves) 12
Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 13-Ozone Contact + ICA WTM-Valves-63 Mechanical Systems 2010 OC-HOV-8 OC-HOV-8, VALVE, BASIN 2 DRAIN, OZONE CONTACTOR, WTP Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 13-Ozone Contact + ICA WTM-Valves-64 Mechanical Systems 2010 OC-HOV-9 OC-HOV-9, VALVE, BASIN 1 DRAIN, OZONE CONTACTOR, WTP Valves Other (Valves) 12 Increased
Maintenance
Lack of Redundancy/Potential Reduced
Efficiency 2 3 15 Low
WTM 13-Ozone Contact + ICA WTM-Valves-65 Mechanical Systems 2010 OC-MO-11 OC-MO-11, INFLUENT VALVE ACTUATOR, OZONE BASIN 1,
OZONE CONTACTOR, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 3 12 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-66 Mechanical Systems 2010 OC-MO-12 OC-MO-12, EFFLUENT VALVE ACTUATOR, OZONE BASIN 1,
OZONE CONTACTOR, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 3 12 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-67 Mechanical Systems 2010 OC-MO-21 OX-MO-21, INFLUENT VALVE ACTUATOR, OZONE BASIN 2,
OZONE CONTACTOR, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 3 12 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-68 Mechanical Systems 2010 OC-MO-22 OC-MO-22, EFFLUENT VALVE ACTUATOR, OZONE BASIN 2,
OZONE CONTACTOR, WTP Valves Other (Valves) 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 3 12 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-69 Mechanical Systems 2010 OC-MOV-11 OC-MOV-11, INFLUENT VALVE, 30 INCH BUTTERFLY, OZONE
BASIN 1, OZONE CONTACTOR, WTP Valves Butterfly 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 4 16 Med-Low
WTM 11-Intake / LLPS WTM-Valves-7 Mechanical Systems 2010 ARV-LL-2 ARV-LL-2, AIR RELIEF VALVE, LL PUMP 2 DISCHARGE, LLPS, WTP Valves Air Valve 17 Rehabilitation Reduced Efficiency 2 4 24 Med-Low WTM 13-Ozone Contact + ICA WTM-Valves-70 Mechanical Systems 2010 OC-MOV-12 OC-MOV-12, EFFLUENT VALVE, 30 INCH BUTTERFLY, OZONE
BASIN 1, OZONE CONTACTOR, WTP Valves Butterfly 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 4 16 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-71 Mechanical Systems 2010 OC-MOV-21 OC-MOV-21, INFLUENT VALVE, 30 INCH BUTTERFLY, OZONE
BASIN 2, OZONE CONTACTOR, WTP Valves Butterfly 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 4 16 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-72 Mechanical Systems 2010 OC-MOV-22 OC-MOV-22, EFFLUENT VALVE, 30 INCH BUTTERFLY, OZONE
BASIN 2, OZONE CONTACTOR, WTP Valves Butterfly 12 No Action Required Lack of Redundancy/Potential Reduced
Efficiency 3 4 16 Med-Low
WTM 13-Ozone Contact + ICA WTM-Valves-73 Mechanical Systems 2010 VALVE-895 VALVE, OZONE ROTOMETER, BASIN 4B INLET, OZONE DESTRUCT
ROOMWTP Valves Other (Valves) 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Valves-74 Mechanical Systems 2010 VALVE-896 VALVE, OZONE ROTOMETER, BASIN 3B INLET, OZONE DESTRUCT
ROOM, WTP Valves Other (Valves) 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Valves-75 Mechanical Systems 2010 VALVE-897 VALVE, OZONE ROTOMETER, BASIN 4A INLET, OZONE DESTRUCT
ROOM, WTP Valves Other (Valves) 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Valves-76 Mechanical Systems 2010 VALVE-898 VALVE, OZONE ROTOMETER, BASIN 3A INLET, OZONE DESTRUCT
ROOM, WTP Valves Other (Valves) 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Valves-77 Mechanical Systems 2010 VALVE-899 VALVE, OZONE ROTOMETER, BASIN 1A INLET, OZONE DESTRUCT
ROOM, WTP Valves Other (Valves) 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Valves-78 Mechanical Systems 2010 VALVE-900 VALVE, OZONE ROTOMETER, BASIN 1B INLET, OZONE DESTRUCT
ROOM, WTP Valves Other (Valves) 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 13-Ozone Contact + ICA WTM-Valves-79 Mechanical Systems 2010 VALVE-901 VALVE, OZONE ROTOMETER, BASIN 2B INLET, OZONE DESTRUCT
ROOM, WTP Valves Other (Valves) 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 11-Intake / LLPS WTM-Valves-8 Mechanical Systems 2010 LL-CKV-1 LL-CKV-1, CHECK VALVE, PUMP 1 EFFLUENT, LLPS, WTP Valves Check Valve 12 Increased
Maintenance Reduced Efficiency 2 5 25 Medium
WTM 13-Ozone Contact + ICA WTM-Valves-80 Mechanical Systems 2010 VALVE-902 VALVE, OZONE ROTOMETER, BASIN 2A INLET, OZONE DESTRUCT
ROOM, WTP Valves Other (Valves) 12 No Action Required
Lack of Redundancy/Potential Reduced
Efficiency 1 3 12 Low
WTM 14-Filters WTM-Valves-81 Mechanical Systems 1974 FS-MOV-1 FS-MOV-1, MOTOR OPERATED VALVE, MASTER BACKWASH,
FILTER GALLERY, WTP Valves Other (Valves) -24 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 14-Filters WTM-Valves-82 Mechanical Systems 1974 V-74 V-74, 36 BUTTERFLY VALVE, FILTERED WATER ISO, EVEN FILTERS, FILTER GALLERY, WTP Valves Butterfly -24 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 14-Filters WTM-Valves-83 Mechanical Systems 1974 V-75 V-75, 36 BUTTERFLY VALVE, FILTERED WATER ISO, ODD FILTERS, FILTER GALLERY, WTP Valves Butterfly -24 Rehabilitation Process/Facility Cannot Operate Without 4 9 54 High WTM 14-Filters WTM-Valves-84 Mechanical Systems 2010 F10-MO-101 F10-MO-101, FILTER 10 ACTUATOR, INFLUENT VALVE, FILTER
DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-85 Mechanical Systems 2010 F10-MO-102 F10-MO-102, FILTER 10 ACTUATOR, EFFLUENT VALVE, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-86 Mechanical Systems 2010 F10-MO-103 F10-MO-103, FILTER 10 ACTUATOR, BACKWASH VALVE, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 4 32 Med-High

Page 23 of 24 ends

Clity of Fairfield
Utility Master Plan Page 695 of 1105 Last Revised: 08-28-23

WATERMAN WTP ASSET RISK ASSESSMENT RESULTS
FacilityCode Process Area Asset Name Discipline Install Year City Asset ID Asset Description Class Subclass Remaining Useful
Life (Years) Action Plan Consequence on Operating Ability LOF COF Risk Score Risk Level WTM 14-Filters WTM-Valves-87 Mechanical Systems 2010 F10-MO-104 F10-MO-104, HC-604, FILTER 10 ACTUATOR, AIR SCOUR VALVE, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-88 Mechanical Systems 2010 F10-MO-105 F10-MO-105, FILTER 10 ACTUATOR, WASTE WASHWATER
VALVE, FILTER DECK, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-89 Mechanical Systems 2010 F-10-MO-106 F10-MO-106, FILTER 10 ACTUATOR, FILTER TO WASTE VALVE,
FILTER GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 11-Intake / LLPS WTM-Valves-9 Mechanical Systems 2010 LL-CKV-2 LL-CKV-2, 24 CHECK VALVE, PUMP 2 EFFLUENT, LLPS, WTP Valves Check Valve 12 Increased
Maintenance Reduced Efficiency 2 5 25 Medium
WTM 14-Filters WTM-Valves-90 Mechanical Systems 2010 F10-MOV-101 F10-MOV-101, VALVE, FILTER 10 INFLUENT, 16 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-91 Mechanical Systems 2010 F10-MOV-102 F10-MOV-102, VALVE, FILTER 10 EFFLUENT, 18 INCH BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-92 Mechanical Systems 2010 F10-MOV-103 F10-MOV-103, VALVE, FILTER 10 BACKWASH, 24 INCH
BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-93 Mechanical Systems 2010 F10-MOV-104 F10-MOV-104, VALVE, FILTER 10 AIR SCOUR, 8 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation
Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-94 Mechanical Systems 2010 F10-MOV-105 F10-MOV-105, VALVE, FILTER 10 WASTE WASH WATER, 24 INCH BUTTERFLY, FILTER DECK, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-95 Mechanical Systems 2010 F-10-MOV-106 F10-M0V-106, VALVE, FILTER 10 FILTER TO WASTE, 12 INCH
BUTTERFLY, FILTER GALLERY, WTP Valves Butterfly 12 Rehabilitation Lack of Redundancy/Potential Reduced
Efficiency 4 5 30 Med-High
WTM 14-Filters WTM-Valves-96 Mechanical Systems 2010 F1-MO-11 F1-MO-11, INFLUENT VALVE ACTUATOR, FILTER 1, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-97 Mechanical Systems 2010 F1-MO-12 F1-MO-12, EFFLUENT VALVE ACTUATOR, FILTER 1, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High
WTM 14-Filters WTM-Valves-98 Mechanical Systems 2010 F1-MO-13 F1-MO-13, BACKWASH VALVE ACTUATOR, FILTER 1, FILTER
GALLERY, WTP Valves Other (Valves) 12
Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 6 4 32 Med-High
WTM 14-Filters WTM-Valves-99 Mechanical Systems 2010 F1-MO-14 F1-MO-14, AIR SCOUR VALVE ACTUATOR, FILTER DECK, WTP Valves Other (Valves) 12 Replace or Run to
Failure
Lack of Redundancy/Potential Reduced
Efficiency 5 4 28 Med-High

Page 24 of 24 ends

Clity of Fairfield
Utility Master Plan Page 696 of 1105 Last Revised: 08-28-23 Water Storage Reservoirs Condition and Risk Assessment
Appendix E

Page 697 of 1105 ends

2020 Research Park Drive
Suite 100
Davis CA 95618
530.756.5905 phone
530.756.5991 fax
westyost.com

TECHNICAL MEMORANDUM
DATE: February 2, 2024 Project No.: 268-60-22-20
SENT VIA: EMAIL
TO: Mike Hether
CC: Stuart Hamilton
FROM: Julia McBride, PE, RCE #90692
REVIEWED BY: Jeff Wanlass, PE, RCE #60930
Amy Kwong, PE, RCE #73213
SUBJECT: Water Storage Reservoirs Condition and Risk Assessment

INTRODUCTION
The City of Fairfield (City) has retained West Yost to develop its 2023 Public Utility Master Plan (PUMP).

Task 5 for the PUMP describes a Water Storage Reservoirs Assessment (Assessment) to evaluate the condition of eight of the City’s reservoirs and to make recommendations for improvements. The following is a summary of the Task 5 Assessment scope of work:
• Prepare comprehensive, multi-discipline condition assessments of up to eight reservoirs. • Utilize the City’s existing risk framework to develop risk factors for each reservoir asset. • Develop recommendations for reservoir improvements to address deficiencies identified based on the condition assessment and/or results from the risk assessment.

The following eight reservoirs were selected for the Assessment: Cement Hill; Eastridge; Goldridge; Mangels; Martin Hill; Nelson Hill; Rancho Solano 3; and Rolling Hills. This technical memorandum (TM) summarizes the methods, findings, and recommendations that comprise the Assessment effort, and is organized into the following sections:
• Condition Assessment
• Risk Assessment
• Recommended Improvements

CONDITION ASSESSMENT
This section discusses the methodology used to assess the condition of the City’s reservoirs and summarizes the site investigation assessment results.

Page 698 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 2 ends

N-C-268-60-22-20-WP-TM4
Methodology
Site investigations of eight reservoirs were conducted by the West Yost team on March 15 and March 16, 2023. The site investigations consisted of visual assessments of general site, mechanical, structural, and electrical assets at each reservoir. The evaluation included visual observations of all reservoir exteriors, and visual observations of four reservoir interiors: Eastridge, Mangels, Rancho Solano 3, and Nelson Hill. The site investigations were conducted by a team that included two City staff members from the Water Services Division, two West Yost project engineers, and three JDH Corrosion (JDH) specialists. The team also took photos and noted visible information (e.g., model number, serial number, size, etc.).

JDH provided corrosion condition assessments for each reservoir and ultrasonic thickness and coating thickness information for each metal reservoir. Ultrasonic thickness testing was used to determine the thickness of each steel reservoir shell and any wall thinning. Coating thickness testing was completed using the dry film thickness testing method. JDH also surveyed the cathodic protection (CP) system on three of five reservoirs that have such systems: Goldridge; Mangels; and Rolling Hills. At Martin Hill, JDH and City staff were unable to locate the rectifier or anode junction box to test the CP system. At Rancho Solano 3, JDH was unable to test the CP system as the reservoir was drained and water must be in the tank to test the CP system. Ground-penetrating radar (GPR) was used to locate rebar and confirm rebar spacing and depth in the concrete reservoirs. Detailed findings from JDH’s work are presented in Appendix A.

TJC and Associates (TJC) provided a preliminary structural assessment for each reservoir. They did not perform a visual inspection, but rather used pictures, record drawings, and information provided by JDH.

TJC conducted a structural assessment of the reservoirs to identify areas of seismic vulnerability and other structural deficiencies. TJC generated hydrodynamic sloshing loads for each reservoir, and calculated stability with respect to sloshing/freeboard, sliding, uplift, buckling and hoop stress. Detailed findings from TJC’s structural assessment are presented in Appendix B.

ATEEM met separately with City staff on March 30, 2023 to provide the electrical and instrumentation evaluations of each reservoir. This evaluation included observation of the incoming service, MCCs, PLCs, Control Panels, and other relevant equipment. Detailed findings from ATEEM’s electrical assessment are presented in Appendix C.

Based on the field observations, West Yost assigned a score to each component using the scoring index defined in Table 1. This information was used in the Risk Assessment presented later in this TM.

Table 1. Visual Condition and Performance Scoring Index Score Condition Score Index Performance Score Index
1 Excellent Component functioning as intended
2 Slight visible degradation In service, but elevated O&M costs 3 Visible degradation In service, but function is moderately impaired 4 Integrity of component moderately compromised In service, but function is highly impaired 5 Integrity of component severely compromised Component is not functioning as intended

Page 699 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 3 ends

N-C-268-60-22-20-WP-TM4
Findings
Table 2 summarizes the reservoir type/material, shape, dimensions, capacity in million gallons (MG), and construction and/or rehabilitation year for each of the inspected reservoirs.

Table 2. Key Parameters for Inspected Reservoirs
Name
Type,
Material Shape Dimensions
Capacity,
MG
Year
Constructed
Year
Rehabilitated
Cement Hill Concrete
(Buried) Rectangular
316 feet x 199 feet
Water Height =
24 feet

10.0 1989 NA
Eastridge Concrete
(Buried) Rectangular
316 feet x 316 feet
Water Height =
24 feet

16.0 2003 NA
Goldridge Steel Circular
Diameter = 122 feet
Water Height =

26.5 feet

2.2 2004 NA
Mangels Steel Circular
Diameter = 103 feet
Water Height =
16 feet

1.0 1990 2010
Martin Hill Steel Circular
Diameter = 135 feet
Water Height =
25 feet

2.7 1980 2010
Nelson Hill Concrete Rectangular
357 feet x 316 feet
Water Height =
24 feet

12.0 1984 NA
Rancho
Solano 3 Steel Circular
Diameter = 143 feet
Water Height =
25 feet

3.1 1988 2009
Rolling Hills Steel Circular
Diameter = 143 feet
Water Height =
25 feet

3.1 1989 2010
Table 3 summarizes the observation comments for the general, structural, corrosion, mechanical, access and safety, and electrical/control system assets for each reservoir visited during the site investigations. A distinction is made in Table 3 between significant concerns warranting attention (bold text) versus lesser concerns and/or observations. Table 3 also summarizes the general condition of each reservoir evaluated.

Each reservoir is summarized as a subsection after Table 3.

Page 700 of 1105 ends

N-C-268-60-22-20-WP-TM4-Tbls

Page 1 of 5 ends

Water Storage Reservoirs Condition and
Risk Assessment TM
Table 3. Reservoir Observations and Concerns
Site Observations, Issues, and Concerns
(a)
Cement Hill – Concrete Reservoir, 10 MG
General • Overall, reservoir is in good condition; there is visible degradation, but function is not impaired
• Site security and reservoir vent in good condition
• Grass on top of the reservoir has the potential to introduce infiltration and inflow • Past issues with vandalism (since addressed)
• Concern over cattle proximity to hatches
Structural • No significant issues observed
Corrosion • Not applicable to concrete reservoirs
Mechanical • Sample tap, water level controls, inlet and outlet piping, chlorine system, and isolation valves with MOVs in good condition
• Calcification and rust spots on effluent pipe
Access and Safety • No significant issues observed
Control System • Several broken lights on site; the lighting system is of advanced age Eastridge – Concrete Reservoir, 16 MG
General • Overall, reservoir is in poor condition; there is visible degradation, and function is moderately impaired
• Overflow and site security in good condition
• Major rust and significant seepage between reservoir cells • Every floor and wall joint has cracks
• Significant ponding on the surface
• Threat of infiltration and inflow into the reservoir
• Wrapped woven fiberglass fabric around miscellaneous columns; fiberglass flakes on the floor • Footing only 2.5 inches higher than ground surface elevation versus a minimum standard of 6 inches
Structural • Cover over the various reinforcing bars ranges from ⅝ inches to 4 ⅞ inches for the primary reinforcing
Corrosion • Not applicable to concrete reservoirs
Mechanical • Sample tap, water level controls, chlorine system, and isolation valves with MOVs in good condition
• Significant rust and corrosion on inlet/outlet piping • Significant calcification between cell transfer penetrations • Butterfly valves seal tight but need recoating
Access and Safety • Fall protection and ladder in good condition • The minimum 7-inch distance between ladder rungs and reservoir shell is not met Control System • Site is subfed from local pump station • Allen-Bradley PLC Model 5/20 should be replaced; it is past its useful life and replacements parts are only available via third party vendors
• PLC communicates via outdated blue hose cable to the pump station PLC; any change to either PLC will require replacement of the blue hose with more modern technology Goldridge – Welded Steel Reservoir, 2.2 MG
General • Overall, the reservoir is in good condition with some slight visible degradation • Reservoir overflow and site security in good condition • Manways have rust
• Only one vent; minimum of two needed to achieve adequate ventilation • Some rust on reservoir shell, cracks between footing and chime • Reservoir has anchor bolts in chairs
• Hatches difficult to operate

Page 701 of 1105 ends

N-C-268-60-22-20-WP-TM4-Tbls

Page 2 of 5 ends

Water Storage Reservoirs Condition and
Risk Assessment TM
Table 3. Reservoir Observations and Concerns
Site Observations, Issues, and Concerns
(a)
Structural • Insufficient freeboard exists due to past code changes; only 4 feet of freeboard is available;

5.6 feet is required under current code
• Sliding failure is not anticipated
• Uplift failure is not anticipated
• Compression buckling failure is not anticipated
• It is expected that the bottom two rings of the reservoir would be overstressed when subjected to the design seismic event
Corrosion • Coating in satisfactory condition
• Minor staining and blemishes visible
Mechanical • Sample tap, isolation valves, inlet and outlet piping, water level controls, and chlorine system in good condition
• Inoperable altitude valve
Access and Safety • Fall protection, cages, ladder, and guardrails in good condition Control System • Generator plug-in
• Level transmitter is located within PLC control panel is connected to a pressure tap, such that there is effectively a water line into the panel; accordingly, the level transmitter should be relocated
• Electrical panels are subject to direct sunlight and should be shaded or otherwise protected from sun exposure
• Allen-Bradley PLC Model 5/20 should be replaced; it is past its useful life and replacements parts are only available via third party vendors
Mangels – Welded Steel Reservoir, 1 MG
General • Overall, reservoir is in excellent condition
• Reservoir hatches, vents, crows nest, manways, and site security in good condition • No physical air gap for overflow piping
• Two 24-inch manways
• Some grout deteriorating around reservoir chime
Structural • Insufficient freeboard exists due to past code changes; 3 feet of freeboard is available; 5.0 feet is required under current code
• Sliding failure is not anticipated
• Uplift failure is not anticipated
• Compression buckling failure is not anticipated
• Hoop stress failure is not anticipated
• Hold-down chairs are not provided around the perimeter of the reservoir Corrosion • Coating in satisfactory condition
• Minor staining and blemishes visible
Mechanical • Sample tap, inlet and outlet piping, isolation valves with MOVs, water level controls, and chlorine system in good condition
• Vaults installed in 2009
• Reservoir recoated in 2009
• Operational altitude valve
Access and Safety • Fall protection, ladders, cages, and guardrails in good condition Control System • Temporary generator plug-in
• Old washdown pump starter panel is located in larger overall panel; pump is no longer in service • Allen-Bradley PLC Model 5/20 should be replaced; it is past its useful life and replacements parts are only available via third party vendors

Page 702 of 1105 ends

N-C-268-60-22-20-WP-TM4-Tbls

Page 3 of 5 ends

Water Storage Reservoirs Condition and
Risk Assessment TM
Table 3. Reservoir Observations and Concerns
Site Observations, Issues, and Concerns
(a)
Martin Hill – Welded Steel Reservoir, 2.7 MG
General • Overall, the reservoir is in good condition with some slight visible degradation • Reservoir overflow, hatches, crows nest, manways, and site security in good condition • Minor site drainage issues
• Two 24-inch manways
• Footing only 4 inches higher than ground surface elevation versus a minimum standard of 6 inches
• Rust on chime
• Grout hard and eroded; doesn’t cover edge of chime
Structural • Insufficient freeboard exists due to past code changes; 3.2 feet freeboard of is available;

5.7 feet is required under current code
• Sliding failure is not anticipated
• Uplift failure is not anticipated
• Compression buckling failure is not anticipated
• Hold-down chairs are not provided around the perimeter of the reservoir • It is expected that the bottom two rings of the reservoir would be overstressed when subjected to the design seismic event
Corrosion • Coating in satisfactory condition
• Minor staining and blemishes visible
• Unable to locate and test cathodic protection system
Mechanical • Sample tap, isolation valves with MOVs, inlet and outlet piping, water level controls, and chlorine system in good condition
• Operational altitude valve, but currently bypassed
Access and Safety • Fall protection, cages, ladder, and guardrails in good condition • Minor rust on ladder rungs
Control System • Kohler backup generator on site
• Micrologix 1400 PLC is no longer sold, it should be maintained as long as possible but will eventually need to be replaced
Nelson Hill – Concrete Reservoir, 12 MG
General • Overall, reservoir is in excellent condition
• Significant updates done in 2022
• Reservoir overflow, hatches, crows nest, manways, and site security in good condition • Poor site grading and drainage
• Cracking on floor
Structural • Roof repairs done in 2019–2020
• Concrete cover over the primary reinforcing ranged from 1 ¼ to 2 ⅝ inches Corrosion • Not applicable to concrete reservoirs
Mechanical • Sample tap, inlet piping, insolation valves with MOVs, isolation valves, water level controls, flow meter, and chlorine system in good condition
• Tideflex mixing check valves not watertight
• Outlet has rust
Access and Safety • Guardrails in good condition
• No significant issues observed
Control System • Small backup generator on site
• The Industrial Gateway communications router is not operating consistently; staff is investigating

Page 703 of 1105 ends

N-C-268-60-22-20-WP-TM4-Tbls

Page 4 of 5 ends

Water Storage Reservoirs Condition and
Risk Assessment TM
Table 3. Reservoir Observations and Concerns
Site Observations, Issues, and Concerns
(a)
Rancho Solano 3 – Welded Steel Reservoir, 3.1 MG
General • Overall, the reservoir is in good condition
• Reservoir overflow, hatches, crows nest, manways, and site security in good condition • Some slight visible degradation due to corrosion
• Sediment has accumulated at the bottom of the reservoir and is hard to remove • Grout on chime chipped, joint caulking peeling
• Earthquake retrofit belt added in 2010
• Footing less than the minimum standard of 6 inches in some places around reservoir perimeter
Structural • Insufficient freeboard exists due to past code changes; 3.4 feet freeboard is available, 5.9 feet is required under current code
• Sliding failure is not anticipated
• Uplift failure is not anticipated
• Compression buckling failure is not anticipated
• Hold-down chairs are not provided around the perimeter of the reservoir • It is expected that the shell rings would be overstressed when subjected to the design seismic event
Corrosion • Coating in satisfactory condition
• Minor staining and blemishes visible
• Unable to test the cathodic protection system as the reservoir was drained Mechanical • Sample tap, isolation valves, water level controls, and chlorine system in good condition • Tideflex mixing check valves used for passive system are not watertight • No mixing when not pumping
• Isolation valves not watertight
• Operational altitude valve
Access and Safety • Fall protection, cages, and guardrails in good condition • Minor rust and wear on ladder
• The distance between guardrail posts exceeds the 8-foot standard Control System • Could not find power meter pedestal; unclear how power is getting to the site • Allen-Bradley PLC Model 5/20 should be replaced; it is past its useful life and replacements parts are only available via third party vendors
Rolling Hills – Welded Steel Reservoir, 3.1 MG
General • Overall, the reservoir is in good condition
• Reservoir overflow, hatches, vents, manways, and site security in good condition • Some visible site degradation due to erosion and corrosion • Entire footing is less than the minimum standard of 6 inches above the ground surface elevation • Minor rust on reservoir belt
• Minor erosion of reservoir chime
Structural • Insufficient freeboard exists due to past code changes; 2.7 feet of freeboard is available,

5.4 feet is required under current code
• Sliding failure is not anticipated
• Uplift failure is not anticipated
• Compression buckling failure is not anticipated
• Hold-down chairs are not provided around the perimeter of the reservoir • It is expected that the shell rings would be overstressed when subjected to the design seismic event
Corrosion • Coating in satisfactory condition
• Minor staining and blemishes visible

Page 704 of 1105 ends

N-C-268-60-22-20-WP-TM4-Tbls

Page 5 of 5 ends

Water Storage Reservoirs Condition and
Risk Assessment TM
Table 3. Reservoir Observations and Concerns
Site Observations, Issues, and Concerns
(a)
Mechanical • Sample tap, inlet and outlet piping, isolation valve with MOV, water level controls, and chlorine system in good condition
• Inoperable altitude valve
Access and Safety • Fall protection, cages, and guardrails in good condition • Tank has ladder cages
Control System • Water is coming out of the pedestal conduit and is flowing onto the ground; algae is growing on the wet surfaces
• Allen-Bradley PLC Model 5/20 should be replaced; it is past its useful life and replacements parts are only available via third party vendors
(a) Bold entries indicate greater concerns warranting attention. All other entries are either lesser concerns or observations.

Page 705 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 9 ends

N-C-268-60-22-20-WP-TM4
It should be noted that requirements have changed since some of the reservoirs were constructed and as a result some of the inspected reservoirs are not in conformance with certain current code requirements or standards; however, such nonconformance does not necessarily warrant action. For example, certain reservoirs do not meet existing standards for footing height above existing ground elevation; however, such standards are based on concerns about flooding of the area around the reservoir, which in most cases is not a concern given the reservoir locations on hilltops or other areas not prone to flooding.

Moreover, bringing a substandard footing height into conformance with existing standards would require significant regrading of the site, with little or no commensurate benefit. Accordingly, this assessment takes into account the practicality and actual benefits of bringing existing reservoirs into conformance with applicable codes and standards, with a focus on the identification of improvements that are cost-effective and result in measurable benefits.

It should also be noted that several reservoirs do not meet current seismic standards, such as freeboard and anchorage; however, this nonconformance is due to changes in applicable codes since the reservoirs were constructed. Changes in operations can bring those reservoirs into compliance with current code requirements and are identified in this TM where applicable.

As of November 2018, safety cages are not considered OSHA compliant for fixed ladder fall protection.

The current OSHA standards requires either a personal fall arrest system or ladder safety system and are defined as follows:
• A Personal Fall Arrest System is a system that arrests a person’s fall from a ladder. The system consists of anchorage, a body harness, connector, and deceleration device or lifeline.

An example of this system is provided in Appendix D.
• A Ladder Safety System is a system designed to eliminate or reduce the possibility of falling from a ladder. A ladder safety system usually consists of a carrier, a lanyard, connectors, and a body harness. These systems include options for either a flexible cable or a rigid rail system. Examples are provided in Appendix D.

Per OHSA requirements, by November of 2036, all cages on a fixed ladder shall be replaced by either a personal fall arrest system or ladder safety system. Since compliance with this requirement is still several years out, it is recommended that the safety cages be removed, and an approved fall protection system be installed when other recommended improvements are implemented.

Cement Hill
Cement Hill is a buried concrete reservoir constructed in 1989. The reservoir is rectangular in shape and has approximately 2 feet of soil on the top slab. The water height is 24 feet, and the outside dimensions are approximately 316 feet by 199 feet. The capacity of the reservoir is approximately 10.0 MG.

Overall, the Cement Hill reservoir is in good condition. There is visible degradation, but its function is not impaired. The reservoir shows various issues of concern related to equipment/surface deterioration, potential site access by local cattle herds, and site lighting. A full engineering evaluation of the reservoir should be performed by temporarily taking the reservoir out of service and inspecting the interior.

Page 706 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 10 ends

N-C-268-60-22-20-WP-TM4
Photo 1
Cement Hill valve vault
Photo 2
Cement Hill Reservoir interior
Eastridge
Eastridge is a buried concrete reservoir constructed in 2003. The reservoir is rectangular in shape and has approximately 2 feet of soil on the top slab. The water height is 24 feet, and the outside dimensions are approximately 316 by 316 feet. The capacity of the reservoir is approximately 16.0 MG.

Overall, the Eastridge reservoir is in poor condition. There is visible degradation, and its function is moderately impaired. The reservoir shows various issues of concern related to equipment/surface deterioration, site ponding, insufficient rebar cover, and antiquated PLC equipment.

Photo 3
Eastridge Reservoir
Photo 4
Eastridge Reservoir cell B interior

Page 707 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 11 ends

N-C-268-60-22-20-WP-TM4
Goldridge
Goldridge is a 2.2 MG welded steel reservoir constructed in 2004. The reservoir has a diameter of 122 feet and a water height of 26.5 feet. Hold-down chairs are provided around the perimeter of the reservoir.

Overall, the Goldridge reservoir is in good condition with some slight visible degradation. The reservoir shows various issues of concern related to equipment/surface deterioration, insufficient freeboard, seismic overstressing concerns, inoperable altitude valving, and antiquated PLC equipment.

Photo 5
Goldridge Reservoir
Photo 6
Goldridge Reservoir interior ladder
Mangels
Mangels is a 1.0 MG welded steel reservoir constructed in 1990 and rehabilitated in 2010. The reservoir has a diameter of 103 feet and a water height of 16 feet. Hold-down chairs are not provided around the perimeter of the reservoir. Overall, the Mangels reservoir is in excellent condition. The Mangels reservoir shows various issues of concern related to equipment/surface deterioration, insufficient freeboard, and antiquated PLC equipment.

Photo 7
Mangels Reservoir
Photo 8
Mangels Reservoir chime

Page 708 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 12 ends

N-C-268-60-22-20-WP-TM4
Martin Hill
Martin Hill is a 2.7 MG welded steel reservoir constructed in 1980 and rehabilitated in 2010. The reservoir has a diameter of 135 feet and a water height of 25 feet. Hold-down chairs are not provided around the perimeter of the reservoir.

Overall, the Martin Hill reservoir is in good condition with some slight visible degradation. The Martin Hill reservoir shows various issues of concern related to equipment/surface deterioration, insufficient freeboard, and seismic overstressing concerns.

Photo 9
Martin Hill Reservoir
Photo 10
Martin Hill Reservoir chime
Nelson Hill
Nelson Hill is a buried concrete reservoir constructed in 1984. The reservoir is rectangular in shape and does not have soil on the top slab. The water height is approximately 24 feet, and the outside dimensions are approximately 357 feet by 316 feet. The capacity of the reservoir is approximately 12.0 MG.

Overall, the Nelson Hill reservoir is in excellent condition. The Nelson Hill reservoir shows issues of concern related to equipment/surface deterioration and insufficient rebar cover.

Photo 11
Nelson Hill Reservoir roof top slab
Photo 12
Nelson Hill Reservoir interior

Page 709 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 13 ends

N-C-268-60-22-20-WP-TM4
Rancho Solano 3
The Rancho Solano 3 is a 3.1 MG welded steel reservoir constructed in 1988 and rehabilitated in 2009.

The reservoir has a diameter of 143 feet and a water height of 25 feet. Hold-down chairs are not provided around the perimeter of the reservoir. The reservoir was retrofitted in 2008 with two “girdle” bands to improve the ability to resist hoop stresses.

Overall, the Rancho Solano 3 reservoir is in good condition. The Rancho Solano 3 reservoir shows various issues of concern related to equipment/surface deterioration, insufficient freeboard, seismic overstressing concerns, and antiquated PLC equipment.

Photo 13
Rancho Solano 3 Reservoir interior
Photo 14
Rancho Solano 3 Reservoir
Rolling Hills
Rolling Hills is a 3.1 MG welded steel reservoir constructed in 1989 and rehabilitated in 2010. The reservoir has a diameter of 143 feet and a water height of 25 feet. Hold-down chairs are not provided around the perimeter of the reservoir. The reservoir was retrofitted in 2009 with two “girdle” bands to improve the ability to resist hoop stresses.

Overall, the Rolling Hills reservoir is in good condition. The reservoir shows various issues of concern related to equipment/surface deterioration, insufficient freeboard, water emanating from the pedestal conduit, inoperable altitude valving, and antiquated PLC equipment.

Page 710 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 14 ends

N-C-268-60-22-20-WP-TM4
Photo 15
Rolling Hills Reservoir
Photo 16
Rolling Hills Reservoir chime

RISK ASSESSMENT
Critical asset condition and performance information collected during the reservoir site visits was used to perform a risk assessment of reservoir facilities. The risk assessment considers both likelihood of failure (LOF) ratings and consequence of failure (COF) ratings to quantify the risks associated with each asset and reservoir facility. Risk results were used to prioritize rehabilitation, replacement, or maintenance actions to meet established service reliability and performance goals.

The risk assessment methodology and results presented in this section are consistent with the results presented in the Condition Assessment section above and with the City’s 2023 Pump Station Asset Management Plan. These results are used as the basis for prioritization of capital improvements described in the Recommended Improvements section later in this TM. Capital improvement project costs and prioritization will be presented in Chapter 9 of the PUMP Report.

Key topics addressed in this section include:
• Risk Methods
• Asset Risk Results
• Reservoir Risk Results
The general approach used in the risk assessment is illustrated in Figure 1. The risk assessment involves development of LOF, COF, and risk scores for each individual asset, and each reservoir facility as a whole.

A rating for LOF is given to each individual asset and those ratings contribute to the overall LOF rating for each reservoir. In addition, a rating for COF is assigned to each reservoir, which is inherited by all individual assets at that reservoir. Asset risk is then calculated based on those asset LOF and asset COF scores.

Similarly, reservoir LOF and COF scores are combined to determine a comprehensive risk score and rating for each reservoir.

Page 711 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 15 ends

N-C-268-60-22-20-WP-TM4
Figure 1. Reservoir Risk Assessment Methodology
Risk Methods
This section describes the methods used to perform the LOF and COF analyses and to determine the resulting risk level for each individual asset and each reservoir facility assessed for the PUMP.

Asset LOF
The asset LOF analysis considers the probability that a failure of a given asset will occur. The analysis includes two “failure modes”, specifically Physical Mortality and Level of Service. The factors considered in assessing each of these failure modes are presented in Table 4.

Table 4. Criteria Used for Asset LOF Evaluation
Failure Mode Criteria/Factor Description
Physical
Mortality Condition Rating
An asset with visible degradation is more likely to fail. While condition and age are often interdependent, newer components may be in poor condition due to environmental conditions or improper maintenance. Condition ratings are assigned to assets during the on-site condition assessment described previously.

Level of Service Performance Rating
An asset that does not perform as designed or intended is a level of service failure. Something does not have to physically happen to the asset for level of service failure to occur.

Asset performance may affect the level of service provided by the reservoir, depending on the role of that asset in day-to-day operations. Performance ratings were assigned to assets based on information obtained during the on-site condition assessment and West Yost’s understanding of the water system operations.

The LOF factors above are translated into numeric rankings of 1 to 5, with 5 indicating the highest LOF. An overall LOF score is determined by adding the two ratings, so each asset will have an overall LOF score of between 2 and 10. The factors and their range of potential ratings for each category are presented in Table 5.

Asset Risk
Asset LOF Asset COF
Reservoir LOF Reservoir COF
Reservoir Risk

Page 712 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 16 ends

N-C-268-60-22-20-WP-TM4
Table 5. Reservoir LOF Rating Factors
Failure Mode Criteria/Factor
Rating
1 2 3 4 5
Physical
Mortality
Condition
Rating Excellent Slight Visible Degradation
Visible
Degradation
Integrity
Moderately
Compromised
Integrity
Severely
Compromised
Level of Service Performance
Rating
Functioning
as intended
In service, but
elevated O&M
costs
In service, but
function is
moderately
impaired
In Service, but
Function is
Highly Impaired
Not
Functioning as
Intended
Reservoir LOF
The LOF for each reservoir was evaluated by averaging the LOF scores of individual assets within each reservoir. Similar to the LOF scoring for assets, the reservoir LOF is rated on a 2 to 10 scale.

Asset and Reservoir COF
The COF analysis considers the impact that an asset or reservoir failure may have on the water system as a whole. As described previously, the COF was evaluated at the reservoir level, and all assets within that reservoir inherit the same COF score. This approach is based on the assumption that due to the relatively small number of assets at a reservoir, all assets are critical to reservoir operation. For each category, the criteria considered in determining the potential COF are presented in Table 6.

Table 6. Criteria Used for Reservoir COF Evaluation
Category Criteria/Factor Description
Operating Ability Type of Customers
in Zone
Water service disruptions impact the community while service is being restored. Critical customers (e.g., hospitals, industries, etc.) may have limited ability to handle prolonged water outages.

Service Reliability Ability to Meet Demand
Scenarios
Depending on the redundancy built into the system, certain zones may be able to meet service demands even with one reservoir offline. Some zones are constructed with no storage redundancy (i.e., Goldridge, Mangels, and Rancho Solano 3); for these reservoirs, there are additional consequences if the reservoir is taken offline for repairs or to be replaced. Since there is no another reservoir available to support the pressure zone, in the event that one of these reservoirs is removed from service, the sole source of supply to the pressure zone becomes the pump station(s) serving the zone. Therefore, in order to assess the severity of an outage for reservoirs in zones with no storage redundancy, the capacity of the pump station(s) serving each of these zones was evaluated for the ability of the pumps to compensate for a sudden lack of storage in the zone. Pump station(s) were reviewed to determine whether they could meet the greatest potential fire flow requirement in the zone, as well as the maximum day demand (MDD) for the zone. If the pump station(s) cannot meet one or both of these requirements on their own (i.e., fire flow and/or MDD), then it is more consequential if the reservoir that supports that pressure zone is taken offline.

The COF factors shown in Table 6 were translated into numeric rankings of 1 to 5, with 5 indicating the highest or worst consequence. Each reservoir is evaluated for the two factors, then are added together, with a resultant overall COF score between 2 and 10. This overall COF is assigned to all assets at that reservoir. The factors and their range of potential ratings for each category are presented in Table 7.

Page 713 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 17 ends

N-C-268-60-22-20-WP-TM4
Table 7. Reservoir COF Rating Factors
Consequence Factor
Rating (1 being the lowest, 5 being the highest)
1 2 3 4 5
Operating
Ability
Type of
Customers
in Zone
Residential Educational/
Commercial Correctional Industrial Hospital
Service
Reliability
Ability to
Meet
Demand
Scenarios
All storage
requirements
(operational,
emergency,
and fire) are
met in the
zone
Emergency or
fire storage
are not met
(operational
storage met)
No storage
redundancy
(one reservoir in
zone) but pump
station
supplying zone
can meet MDD
plus fire flow(a)
No storage
redundancy
(one reservoir in
zone) and pump
station cannot
meet MDD plus
fire flow(a)
No storage
redundancy
(one reservoir in
zone) and pump
station cannot
meet MDD(a)
(a) Pump station capacity is assumed to be firm, meaning the largest pump is offline at each pump station. The capacity per pump at each pump station is based on the measured flow of each pump, as recorded in Table 2-2 of the City's Pump Station Asset Management Plan Update (West Yost, 2023).

Reservoir Risk Score Calculation
Upon determining all of the asset LOF and COF scores, a risk score is calculated for each reservoir using the following formula:

Reservoir Risk Score = Average of Asset LOF Scores x Reservoir COF Score Asset Risk Results
As noted above, the aggregated score for asset LOF and COF ranges from 2 to 10. By plotting the LOF and COF scores against each other, an overall risk level is assigned to each asset group. Risk levels are prioritized into five risk levels: Low, Medium-Low, Medium, Medium-High, and High, each of which is color-coded in Table 8. Table 8 shows the total number of assets that fall into each LOF and COF category.

These risk levels are assigned to the various cells using best engineering judgment to determine which combinations of score warrant the highest levels of concern versus those that warrant lesser levels of concern. Risk levels have been adjusted from those developed in the City’s 2023 Pump Station Asset Management Plan.

Page 714 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 18 ends

N-C-268-60-22-20-WP-TM4
Table 8. Reservoir Asset Risk Level Results
Number of
Assets
COF Score
2 3 4 5 6 7 8 9 10 Total
LOF Score
2 0 1 0 2 9 0 0 0 0 12
3 0 0 0 1 2 0 0 0 0 3
4 5 5 0 10 5 1 0 0 0 26
5 0 2 0 1 8 0 0 0 0 11
6 5 0 0 4 5 1 0 0 0 15
7 3 3 0 2 6 7 0 0 0 21
8 0 0 0 2 1 0 0 0 0 3
9 0 2 0 2 2 1 0 0 0 7
10 0 0 0 1 0 1 0 0 0 2
Total 13 13 0 25 38 11 0 0 0 100
Risk Levels Low Medium-Low Medium Medium-High High
The asset risk assessment results are summarized in Table 9, which lists the total number and percentage of components that fall in each risk level. The majority of the assets (71 percent) fall into the Medium or Medium-Low risk level.

Table 9. Reservoir Asset Risk Level Results Summary
Risk Level Number of Assets Percent of Total
Low 3 3
Medium-Low 39 39
Medium 32 32
Medium-High 24 24
High 2 2
Total 100 100%

Page 715 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 19 ends

N-C-268-60-22-20-WP-TM4
Reservoir Risk Results
Figure 2 shows the percentage of assets in each reservoir that fall within each risk level (as represented by the colored bars). As shown in the figure, Eastridge reservoir is composed of approximately 90-percent of High and Medium-High risk assets, whereas Martin Hill reservoir has no High or Medium-High risk assets.

Figure 2. Risk Levels of Assets by Reservoir, Percent of Total 0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Cement Hill Eastridge Goldridge Mangels Martin Hill Nelson Hill Rancho Solano 3
Rolling Hills
Percent of Total Number of Components in Risk Level Per Reservoir High Med-High Medium Med-Low Low

Page 716 of 1105 ends

TM – City of Fairfield
February 2, 2024

Page 20 ends

N-C-268-60-22-20-WP-TM4
Table 10 presents the average asset LOF score, COF score, risk score, and risk level for each reservoir, ranked from highest to lowest risk. As indicated in Table 10, Eastridge is rated as a Medium-High risk reservoir, Rolling Hills and Martin Hill are rated as Medium-Low risk reservoirs, while the other five reservoirs are all rated as Medium risk. These results provide the basis for prioritizing the timing of the capital improvements described later in this TM. It should be noted that these results do not directly indicate a safety, health, or other risk to the City or its residents, rather, they should be used to assist the City in identifying facilities to be prioritized during capital improvement planning.

Table 10. Reservoir Risk Assessment Results by Reservoir Reservoir
LOF Score
(average of
assets) COF Score
Risk
Score
Risk
Levell
(Priority)
Eastridge 7.1 7 49.6 Medium-High
Rancho Solano 3 5.3 6 31.5 Medium
Nelson Hill 4.7 6 28.0 Medium
Goldridge 5.4 5 27.1 Medium
Mangels 4.5 6 27.0 Medium
Cement Hill 5.3 5 26.4 Medium
Rolling Hills 5.5 3 16.4 Medium-Low
Martin Hill 5.5 2 10.9 Medium-Low

RECOMMENDED IMPROVEMENTS
Recommendations for improvements at each reservoir are listed in Table 11. Key items of note affecting multiple reservoirs include the following:

1. All sites require repairing of cracks/leaks and/or spot repair of corroded elements.

2. Five sites (Eastridge, Goldridge, Mangels, Rancho Solano 3, and Rolling Hills) require replacement of existing antiquated PLC equipment.

3. Four sites (Goldridge, Martin Hill, Rancho Solano 3, and Rolling Hills) require reinforcement of the reservoir to mitigate seismic overstressing.

4. Test CP system at Rancho Solano 3 when water is in the reservoir. Confirm location of rectifier or anode junction box to test CP system at Martin Hill and confirm it is working properly.

Page 717 of 1105 ends

N-C-268-60-22-20-WP-TM4-Tbls
City of Fairfield
Water Storage Reservoirs Condition and
Risk Assessment TM
Table 11. Reservoir Improvement Recommendations
Reservoir/Type Recommendations
Cement Hill –
Concrete
• Repair all cracks/leaks with epoxy injection
• Perform a full engineering evaluation of reservoir when able to access reservoir interior • Install cattle fence
• Replace broken lights
Eastridge –
Concrete
• Mitigate site ponding
• Repair all cracks/leaks with epoxy injection
• Perform a more extensive reinforcing study to determine the limits of reinforcing that is not in the proper location • Determine wall thickness to calculate the as-built “d” distance (i.e., the distance between the compression face and the tension reinforcing).
• Replace the existing Allen-Bradley Model 5/20 PLC
Goldridge –
Welded Steel
• Spot repair surface corrosion and deterioration during next maintenance cycle • Repair gaps between chime and foundation where the grout has failed with sealant or mastic • Enlist a corrosion engineer to annually inspect the cathodic protection system • Lower operating level of the reservoir by approximately 2 feet to mitigate insufficient freeboard • Reinforce bottom two rings of the reservoir to mitigate seismic overstressing • Replace the existing Allen-Bradley Model 5/20 PLC
• Replace altitude valve with motor operated valve
• Remove ladder cage and replace with personal fall arrest system or ladder safety system by November 2036 Mangels –
Welded Steel
• Spot repair surface corrosion and deterioration during next maintenance cycle • Repair gaps between chime and foundation where the grout has failed with sealant or mastic • Enlist a corrosion engineer to annually inspect the cathodic protection system • Lower operating level of the reservoir by approximately 2.5 feet to mitigate insufficient freeboard • Replace the existing Allen-Bradley Model 5/20 PLC
• Remove ladder cage and replace with personal fall arrest system or ladder safety system by November 2036 Martin Hill –
Welded Steel
• Spot repair surface corrosion and deterioration during next maintenance cycle • Repair gaps between chime and foundation where the grout has failed with sealant or mastic • Locate rectifier or anode junction box to test existing cathodic protection system and confirm it is operating properly • Lower operating level of the reservoir by approximately 2.75 feet to mitigate insufficient freeboard • Reinforce bottom two rings of the reservoir to mitigate seismic overstressing • Remove ladder cage and replace with personal fall arrest system or ladder safety system by November 2036 Nelson Hill –
Concrete
• Repair all cracks/leaks with epoxy injection
• Investigate 1¼-inch rebar cover to determine whether this is an anomaly, or a significant portion of the reinforcing has suboptimal cover Rancho Solano 3 –
Welded Steel
• Spot repair surface corrosion and deterioration during next maintenance cycle • Repair gaps between chime and foundation where the grout has failed with sealant or mastic • Test existing cathodic protection system when tank is not drained • Lower operating level of the reservoir by approximately 2.75 feet to mitigate insufficient freeboard • Reinforce rings of the reservoir to mitigate seismic overstressing • Replace the existing Allen-Bradley Model 5/20 PLC
• Remove ladder cage and replace with personal fall arrest system or ladder safety system by November 2036 Rolling Hills –
Welded Steel
• Spot repair surface corrosion and deterioration during next maintenance cycle • Repair gaps between chime and foundation where the grout has failed with sealant or mastic • Enlist a corrosion engineer to annually inspect the cathodic protection system • Replace the existing Allen-Bradley Model 5/20 PLC
• Replace altitude valve with motor operated valve
• Address issue of water coming out of the pedestal conduit • Remove ladder cage and replace with personal fall arrest system or ladder safety system by November 2036

Page 718 of 1105 ends

JDH Corrosion Assessment
Appendix A

Page 719 of 1105 ends

Equipment Frequency
Process Key
Well Pump - WWP071 M
M
M
Pump Motor A
A
Motor Starter A
A

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Check for any excessive heat coming from any wires or connections with a infrared thermometer Deenergize panel and tighten all electrical connections Well Pump and Motor - PREVENTIVE MAINTENANCE SCHEDULE
Description of Maintenance Task
Check for unusual sounds or vibrations
Verify flow and pressure data are within designed range Check discharge head for any leaks
Check current draw from each phase by clipping a CT ammeter around each wire and record readings while the pump is running at constant outlet pressure and flow.

Turn off power and disconnect the motor wire leads in the control box. With an ohmmeter measure the resistance between the leads and record the values.

Reference Grundfos SP/SPE Installation and Operating Instructions pages 26-29 for more information
N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 720 of 1105 Equipment Maintenance Schedules Equipment Frequency
Process Key
ARV's - 561/562
M
ARV's - 563
M

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
www.valmatic.com
Air Release Valves - PREVENTIVE MAINTENANCE SCHEDULE
Description of Maintenance Task
Valves require no schedule lubrication and/or maintenance Check valves for leaks, if leakage occurs repair valve as needed.

Reference Val-Matic O&M Manual ARSL-OM1-3 page 3 for more information Valve requires no schedule lubrication and/or maintenance Check valve for leaks, if leakage occurs repair valve as needed.

Reference Val-Matic O&M Manual ARCO-OM1-4 page 5 for more information N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 721 of 1105 Equipment Maintenance Schedules Equipment Frequency Description of Maintenance Task
Process Key
Check Valves - WCV071/072/073 Valves require no schedule lubrication and/or maintenance Q Inspect for leakage by listening for leakage noise from the valve while the pump is shut down.

Reference Val-Matic O&M page 6
https://www.valmatic.com/Portals/0/pdfs/SCV-OM1-4.pdf

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Check Valves - PREVENTIVE MAINTENANCE SCHEDULE
N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 722 of 1105 Equipment Maintenance Schedules Equipment Frequency
Process Key
Flow Meter - WFM007 A

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Flow Meter - PREVENTIVE MAINTENANCE SCHEDULE
Description of Maintenance Task
Calibrate Flow Meter
https://www.emerson.com/documents/automation/manual-rosemount-8750w-transmitter-hartprotocol-reference-en-4854858.pdf N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 723 of 1105 Equipment Maintenance Schedules Equipment Frequency
Process Key
Filter Vessel SST
Filters A

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Filter Vessel - PREVENTIVE MAINTENANCE SCHEDULE
Description of Maintenance Task
Inspect filter vessel, vessel bolts and Buna-N O-ring for any damage Replace 1 year after they have been put into service as long as they have not exceeded the 25-35 psi for replacement
Parker Technical Support - James Willard (940)-327-6494 N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 724 of 1105 Equipment Maintenance Schedules Equipment Frequency
Process Key
Booster Pump - WBP007 M
M
M
A

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Booster Pump - PREVENTIVE MAINTENANCE SCHEDULE
Description of Maintenance Task
Check for unusual sounds or vibrations when the well pump is operating Check and record flow and pressure data and verify that they are in the expected ranges Check all pump connections for any leaks
Pump bearings and shaft seal are maintenance free
Motors fitted with grease fittings must be lubricated with a high temperature lithium-based grease.

Grease motor before removing it from service if motor is going to be idle for more than 6 months Reference instructions on fan cover and operating hours chart on pare 11 of the Grundfos O&M Manual
N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 725 of 1105 Equipment Maintenance Schedules Equipment Frequency
Process Key
Flow Control and Pressure Reducing
Valve - PRC082
Q

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Flow Control and Pressure Reducing Valve - PREVENTIVE MAINTENANCE SCHEDULE Description of Maintenance Task
Valves require no schedule lubrication and/or maintenance Inspect valve for proper operation.

Reference CLA-VAL O&M Manual 49-01/649-01 pages 4 and 5 for disassembly instructions if needed.
www.cla-val.com
N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 726 of 1105 Equipment Maintenance Schedules Equipment Frequency
Process Key
Pump Head A
Chemical Injector A
Chemical Piping/Tubing M
A
Pulsation Dampener M
Ferric Sulfate Tank M
Poly-Spillcart M
A

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Inspect Tank for any cracks or other structural issues
Inspect cart containment for any ferric sulfate or other liquid Inspect cart for any cracks or other structural issues
Ferric Sulfate System - PREVENTIVE MAINTENANCE SCHEDULE Description of Maintenance Task
Rebuild Pump Head - Reference Meter Pump Instructions Manual for detailed instructions Remove clean and/or rebuild injector - Reference Meter Pump Instructions Manual for detailed instructions
http://lmipumpcatalog.com/wp-content/uploads/2016/02/LMI-ROYTRONIC-A-Series-MeteringPump-Instruction-Manual.pdf Inspect all piping and tubing for any leakage or signs of wear or other issues Replace Tubing as needed
Check pulsation dampener to verify static PSI is in expected range N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 727 of 1105 Equipment Maintenance Schedules Equipment Frequency Description of Maintenance Task
Process Key
Tablet Chlorinator Cleaning A Clean Chlorination System - Reference Page 7, section B for detailed instructions http://puraquaproducts.com/product-documents/Manual-Accu-Tab-3075-Chlorinator.pdf Chlorinator Valve Cleaning A Disassemble and clean Float, Check and Solenoid valves Reference Accu-Tab 3075 O&M Manual for troubleshooting information Chlorinator Booster Pump A Motors fitted with grease fittings must be lubricated with a high temperature lithium-based grease.

Grease motor before removing it from service if motor is going to be idle for more than 6 months Reference instructions on fan cover and operating hours chart on pare 11 of the Grundfos O&M Manual

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Chlorinator - PREVENTIVE MAINTENANCE SCHEDULE
N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 728 of 1105 Equipment Mentenance Schdules Equipment Frequency
Process Key
Chlorine Analyzer - WCLAN007 SST/D
SST/M
SSH

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Chlorine Analyzer - PREVENTIVE MAINTENANCE SCHEDULE
Description of Maintenance Task
Verify/Compare Analyzer reading to hand held colorimeter Calibrate Analyzer per Manufactures Recommendations
Clean and Shutdown Analyzer per Manufactures Recommendations O&M manual not Available online at this time.
https://www.evoqua.com/en/evoqua/products--services/disinfection-systems/disinfectionprocess-analyzers--controllers/depolox-400-m-analyzer/ N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 729 of 1105 Equipment Maintenance Schedules Equipment Frequency
Process Key
Emergency Shower and Eye /Face
Wash M

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Emergency Shower and Eye/Face Wash - PREVENTIVE MAINTENANCE SCHEDULE Description of Maintenance Task
Operate Emergency Shower and Eyewash and verify proper operation Disassemble and clean shower head and eyewash diffusers as needed to maintain adequate flow Reference Haws Installation and O&M Instructions for more Information https://www.hawsco.com/wp-content/uploads/2020/07/8300-8300CRP.pdf N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 730 of 1105 Equipment Maintenance Schedules Equipment Frequency
Process Key
HVAC Units SA
Exhaust Fan SA

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down

HVAC - PREVENTIVE MAINTENANCE SCHEDULE
Description of Maintenance Task
Check unit for proper operation and clean unit filters
https://na2.electroluxmedia.com/Original/Electrolux/Electrolux%20Assets/Document/Complete% 20Owners%20Guide/English/16120300A31829en.pdf
Check unit for proper operation and any unusual sounds or vibration N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 731 of 1105 Equipment Maintenance Schedules Equipment Frequency
Process Key
Well Level Transmitter A
A

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Well Level Transmitter - PREVENTIVE MAINTENANCE SCHEDULE Description of Maintenance Task
Check well level reading and record
Calibrate well level transmitter per manufactures recommendations https://www.drexelbrook.com/-/media/ametekdrexelbrook/download_links/manual-universal-vlevel-system.pdf?la=en&revision=09186487-9af5-4c33-8947-0be0936e6609 N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 732 of 1105 Equipment Maintenance Schedules Equipment Frequency
Process Key
Exterior Building and Area Lights Q
Interior Emergency Lights Q
MCC Q
A
Backflow Device A
Fire Extinguishers M

FREQUENCY KEY
D - Daily
W - Weekly
M - Monthly
Q - Quarterly
SA - Semi-Annually
A - Annually
SST - Seasonal Start-Up
SSH - Seasonal Shut-Down
Check all fire extinguisher to verify extinguisher indication is in the GREEN

PREVENTIVE MAINTENANCE SCHEDULE
Description of Maintenance Task
Check lights for proper operation
Check lights for proper operation
Push to Test Status Indication lights to verify proper indication Clean all MCC cooling fans air filters
Verify BFD has been tested annually
N-C-405-60-19-73-WP-R-OPS PLAN-App A
City of Santa Rosa
Operations Plan - Appendix A Page 733 of 1105 Equipment Maintenance Schedules TJC Structural Assessment
Appendix B

Page 734 of 1105 ends

City of Fairfield
Condition Assessment
of
Eight Reservoirs
Fairfield, California
TJCAA PROJECT NO. 122084
Date: JULY 2023
Prepared by:

Terence Cavanagh, S.E.

TJC and Associates, Inc.

D R A F T

Page 735 of 1105 ends

City of Fairfield Condition Assessment
July 2023 Page 2

Table of Contents

1. INTRODUCTION ....................................................................................... 3

2. RESERVOIR DISCUSSION AND FINDINGS ............................................... 3

2.1 Concrete Reservoirs ........................................................................ 4

2.2 Welded Steel Reservoirs .................................................................. 5

2.3 Rolling Hills Reservoir ...................................................................... 7

3. LIMITATIONS .......................................................................................... 8

4. SUMMARY OF FINDINGS .......................................................................... 8

4.1 Concrete Reservoirs ........................................................................ 8

4.2 Welded Steel Reservoirs .................................................................. 8 Appendix A – JDH Report ................................................................................ 10

REVISION RECORD
Revision No.
0 Original

Page 736 of 1105 ends

City of Fairfield Condition Assessment
July 2023 Page 3

1. INTRODUCTION
The City of Fairfield is developing a Water Utility Master Plan and conducting a Rate Study Project. As part of plan development, TJC and Associates, Inc. (TJCAA) is providing structural evaluation of water system facilities. This report documents the results of TJCAA’s limited structural evaluation of storage reservoirs in the water system.

This evaluation included review of available documentation including a condition assessment report developed by JDH Consultants, Inc. (JDH) for this project. The following reservoirs are included in this assessment.

Concrete Reservoirs

1. Cement Hill Reservoir – 10 million gallon (MG) concrete tank (circa 1989)

2. Eastridge Reservoir – 16 MG concrete tank (circa 2003)

3. Nelson Hill Reservoir – 12 MG concrete tank (circa 1984) Welded Steel Reservoirs

1. Gold Ridge Reservoir – 2.2 MG welded steel tank (circa 2004)

2. Mangels Reservoir – 1.0 MG welded steel tank (circa 1990)

3. Martin Hill Reservoir – 2.7 MG welded steel tank (circa 2010)

4. Rancho Solano 3 Reservoir – 3.1 MG welded steel tank (circa 1988)

5. Rolling Hills Reservoir – 3.1 MG welded steel tank (circa 1989) TJCAA was retained by the City to provide a preliminary structural assessment of the tanks’ as-built conditions. TJCAA did not perform a visual inspection of the reservoirs, however, JDH performed a visual inspection and provided a report detailing an assessment of the existing condition of the reservoirs. In addition to a visual inspection, JDH also provided the following:

1. Ultrasonic Thickness Survey – estimated thicknesses of the various steel plates in the welded steel reservoirs.

2. Coating Thickness Testing – estimated thicknesses of the coating on various steel plates in the welded steel reservoirs.

3. Ground-Penetrating Radar – estimated depth and spacing for the rebar in the cast-in-place concrete reservoirs.

The JDH report can be found in Appendix A.

2. RESERVOIR DISCUSSION AND FINDINGS
TJCAA’s assessment of the reservoirs was limited to review of available engineering drawings for each reservoir and data provided by JDH in its condition assessment report (Appendix A).

Page 737 of 1105 ends

City of Fairfield Condition Assessment
July 2023 Page 4

2.1 Concrete Reservoirs

2.1.1 Cement Hill Reservoir
The Cement Hill Tank is a buried concrete reservoir constructed in 1989. The reservoir is rectangular in shape and has approximately 2 feet of soil on the top slab. The water height is 24 feet and the outside dimensions are approximately 316 x 199 feet. The capacity of the reservoir is approximately 10 MG.

Photos of the reservoir appear to show that it is in relatively good condition. No significant structural issues were reported by JDH. JDH was not, however, able to access the interior of the reservoir and therefore was only able to take photographs of the interior from the roof access hatch.

Based on review of the record drawings, the reservoir appears to have been constructed in a manner consistent with other reservoirs in the late 1980s. No significant structural issues were identified through TJCAA’s review of the as-built drawings. However, due to significant increases in design seismic ground motion values over the past 30 years, TJCAA recommends a full engineering evaluation of the reservoir components.

2.1.2 Eastridge Reservoir
Eastridge Reservoir is a buried concrete reservoir constructed in 2003. The reservoir is rectangular in shape and has approximately 2 feet of soil on the top slab. The water height is 24 feet and the outside dimensions are approximately 316 x 316 feet. The capacity of the reservoir is approximately 16 MG.

Photos of the reservoir appear to show that it is in relatively good condition. No significant structural issues were reported by JDH. JDH did, however, identify some leakage that has occurred through the walls from one cell to another, and one area of copper corrosion staining. Both items can cause corrosion in the reinforcing steel and therefore should be rectified as soon as possible.

Based on review of the record drawings, the reservoir appears to have been constructed in a manner consistent with other reservoirs in the early 2000s. No significant structural issues were identified through TJCAA’s review of the as-built drawings.

One item that came up during the review of JDH’s data is the concrete cover of the rebar. TJCAA noticed that cover over the various reinforcing bars ranges from ⅝ inch to 4⅞ inches for the primary reinforcing. Typical concrete cover for these types of structures is specified as 2 inches. Reduced cover can reduce the protection to the reinforcing steel. Increased cover can reduce the “d” distance (distance between the compression face and the tension reinforcing) within the wall and therefore reduce the wall’s capacity to carry the design loads.

TJCAA recommends performing a more extensive reinforcing study to determine the limits of reinforcing that is not in the proper location. In addition, the actual wall thickness should be determined to calculate the as-built “d” distance. In addition to further field investigation, due to increases in design seismic ground motion values over the past 20 years, TJCAA recommends a full engineering evaluation of the reservoir components.

Page 738 of 1105 ends

City of Fairfield Condition Assessment
July 2023 Page 5

2.1.3 Nelson Hill Reservoir
Nelson Hill Reservoir is a buried concrete reservoir constructed in 1984. The reservoir is rectangular in shape and does not have soil on the top slab. The water height is approximately 24 feet and the outside dimensions are approximately 357 x 316 feet.

The capacity of the reservoir is approximately 12 MG.

Photos of the reservoir appear to show that it is in relatively good condition. No significant structural issues were reported by JDH. JDH did, however, identify some leakage that has occurred through the walls from one cell to another. This leakage can corrode the reinforcing steel and therefore should be rectified as soon as possible.

Based on review of the record drawings, the reservoir appears to have been constructed in a manner consistent with other reservoirs in the early 1980s. No significant structural issues were identified through TJCAA’s review of the as-built drawings.

Concrete cover over the primary reinforcing ranged from 1¼ to 2⅝ inches. While these values are less critical than the cover found in the Eastridge Reservoir, the 1¼-inch cover should be further investigated to determine whether this is an anomaly, or a significant portion of the reinforcing has suboptimal cover. In addition to further field investigation, due to significant increases in design seismic ground motion values over the past 40 years, TJCAA recommends a full engineering evaluation of the reservoir components.

2.2 Welded Steel Reservoirs

2.2.1 Gold Ridge Reservoir
Gold Ridge Reservoir is a 2.2 MG welded steel reservoir constructed in 2004. The reservoir has a 122-foot diameter and a water height of 26.5 feet. Hold-down chairs are provided around the perimeter of the reservoir.

Photos of the reservoir show that it appears to be in relatively good condition. No significant structural issues were reported by JDH. JDH did, however, identify some areas of corrosion that should be spot-repaired. In addition, JDH identified loss of grout below the chime plate. This should be rectified as soon as possible.

TJCAA performed engineering calculations in accordance with AWWA D100-21 to determine maximum anticipated slosh height, anticipated potential for sliding, anticipated potential for uplift, maximum compression buckling stress, and maximum hoop stress. For the design seismic event, TJCAA’s findings are as follows:
• Slosh Height – 5.6 feet – Insufficient freeboard has been provided. • Available Freeboard – 4 feet.
• Sliding – Failure due to sliding is not anticipated.
• Uplift – Failure due to uplift is not anticipated.
• Buckling – Failure due to compression buckling is not anticipated. • Hoop Stress – The bottom two rings of the reservoir would be overstressed when subjected to the design seismic event. Reinforcement will be required to correct this condition.

Insufficient freeboard may be mitigated by lowering the operating level of the reservoir by approximately 2 feet.

Page 739 of 1105 ends

City of Fairfield Condition Assessment
July 2023 Page 6

2.2.2 Mangels Tank
Mangels Reservoir is a 1.0 MG welded steel reservoir constructed in 1990. The reservoir has a 103-foot diameter and a water height of 16 feet. Hold-down chairs are not provided around the perimeter of the reservoir.

Photos of the reservoir appear to show that it is in relatively good condition. No significant structural issues were reported by JDH. JDH did, however, identify some areas of corrosion that should be spot-repaired. In addition, JDH identified loss of grout below the chime plate. This should be rectified as soon as possible.

TJCAA performed engineering calculations in accordance with AWWA D100-21 to determine maximum anticipated slosh height, anticipated potential for sliding, anticipated potential for uplift, maximum compression buckling stress, and maximum hoop stress. For the design seismic event, TJCAA’s findings are as follows:
• Slosh Height – 5.0 feet – Insufficient freeboard has been provided. • Available Freeboard – 3 feet.
• Sliding – Failure due to sliding is not anticipated.
• Uplift – Failure due to uplift is not anticipated.
• Buckling – Failure due to compression buckling is not anticipated. • Hoop Stress – Failure due to hoop tensile stress is not anticipated.

Insufficient freeboard may be mitigated by lowering the operating level of the reservoir by approximately 2.5 feet.

2.2.3 Martin Hill Reservoir
Martin Hill Reservoir is a 2.7 MG welded steel reservoir constructed in 2010. The reservoir has a 135-foot diameter and a water height of 25 feet. Hold-down chairs are not provided around the perimeter of the reservoir.

Photos of the reservoir appear to show that it is in relatively good condition. No significant structural issues were reported by JDH. JDH did, however, identify some areas of corrosion that should be spot-repaired.

TJCAA performed engineering calculations in accordance with AWWA D100-21 to determine maximum anticipated slosh height, anticipated potential for sliding, anticipated potential for uplift, maximum compression buckling stress, and maximum hoop stress. For the design seismic event, TJCAA’s findings are as follows:
• Slosh Height – 5.7 feet – Insufficient freeboard has been provided. • Available Freeboard – 3.2 feet.
• Sliding – Failure due to sliding is not anticipated.
• Uplift – Failure due to uplift is not anticipated.
• Buckling – Failure due to compression buckling is not anticipated. • Hoop Stress – The bottom two rings of the reservoir would be overstressed when subjected to the design seismic event. Reinforcement will be required to correct this condition.

Insufficient freeboard may be mitigated by lowering the operating level of the reservoir by approximately 2.75 feet.

Page 740 of 1105 ends

City of Fairfield Condition Assessment
July 2023 Page 7

2.2.4 Rancho Solano 3 Reservoir
The Rancho Solano 3 Reservoir is a 3.0 MG welded steel reservoir constructed in 1988.

The reservoir has a 143-foot diameter and a water height of 25 feet. Hold-down chairs are not provided around the perimeter of the reservoir. The reservoir was retrofitted in 2008 with two “girdle” bands to improve the ability to resist hoop stresses.

Photos of the reservoir appear to show that it is in relatively good condition. No significant structural issues were reported by JDH. JDH did, however, identify some areas of corrosion that should be spot-repaired. In addition, JDH identified loss of grout below the chime plate. This should be rectified as soon as possible.

TJCAA performed engineering calculations in accordance with AWWA D100-21 to determine maximum anticipated slosh height, anticipated potential for sliding, anticipated potential for uplift, maximum compression buckling stress, and maximum hoop stress. For the design seismic event, TJCAA’s findings are as follows:
• Slosh Height – 5.9 feet – Insufficient freeboard has been provided. • Available Freeboard – 3.4 feet.
• Sliding – Failure due to sliding is not anticipated.
• Uplift – Failure due to uplift is not anticipated.
• Buckling – Failure due to compression buckling is not anticipated. • Hoop Stress – All the shell rings of the reservoir would be overstressed when subjected to the design seismic event. Reinforcement (in addition to that already provided) will be required to correct this condition.

Insufficient freeboard may be mitigated by lowering the operating level of the reservoir by approximately 2.75 feet.

2.3 Rolling Hills Reservoir
Rolling Hills Reservoir is a 3.1 MG welded steel reservoir constructed in 1989. The reservoir has a 143-foot diameter and a water height of 25 feet. Hold-down chairs are not provided around the perimeter of the reservoir. The reservoir was retrofitted in 2009 with two “girdle” bands to improve the ability to resist hoop stresses.

Photos of the reservoir appear to show that it is in relatively good condition. No significant structural issues were reported by JDH. JDH did, however, identify some areas of corrosion that should be spot-repaired.

TJCAA performed engineering calculations in accordance with AWWA D100-21 to determine maximum anticipated slosh height, anticipated potential for sliding, anticipated potential for uplift, maximum compression buckling stress, and maximum hoop stress. For the design seismic event, TJCAA’s findings are as follows:
• Slosh Height – 5.4 feet – Insufficient freeboard has been provided. • Available Freeboard – 2.7 feet.
• Sliding – Failure due to sliding is not anticipated.
• Uplift – Failure due to uplift is not anticipated.
• Buckling – Failure due to compression buckling is not anticipated. • Hoop Stress – All the shell rings of the reservoir would be overstressed when subjected to the design seismic event. Reinforcement (in addition to that already provided) will be required to correct this condition.

Page 741 of 1105 ends

City of Fairfield Condition Assessment
July 2023 Page 8
Insufficient freeboard may be mitigated by lowering the operating level of the reservoir by approximately 3 feet.

3. LIMITATIONS
TJCAA did not receive geotechnical information for each specific site. TJCAA has assumed adequate soil for supporting the reservoirs and no significant issues related to soil that would require special foundations, such as pier-supported foundations.

TJCAA’s evaluation has been based on information provided in as-built drawings along with the JDH report. TJCAA has not ventured to assess the accuracy of the information provided. Therefore, any inaccurate information may have been used to develop the findings and recommendations within this document.

4. SUMMARY OF FINDINGS

4.1 Concrete Reservoirs
The concrete reservoirs were found to be in generally good condition; however, JDH reported leaking cracks between the various cells, corrosion of concrete, and inadequate cover for the rebar. TJCAA recommends the following:

1. Repair all cracks that are leaking within the reservoirs. This can be done with epoxy injection to seal the cracks.

2. Repair and restore any corrosion that is found within the concrete.

3. Conduct a more extensive evaluation of the concrete cover to determine whether the inadequate values are isolated cases or occur throughout the reservoirs. If the locations of the inadequate cover are structurally significant, TJCAA recommends the following:
• Coating the surface to provide additional protection for the rebar. • Building up additional concrete to provide additional protection for the rebar.

Where too much cover is provided, TJCAA recommends the following:
• Engineering analysis to determine whether the resulting structural section is adequate to resist the anticipated internal forces.

4.2 Welded Steel Reservoirs
JDH identified corrosion that should be spot-repaired as soon as possible along with replacement of grout under the chime of the reservoir. JDH also recommended periodic coating and inspections of the reservoirs to keep them from deteriorating further.

TJCAA’s evaluation found that all five of the welded steel reservoirs lacked sufficient freeboard. Limited freeboard will result in water impinging on the roof plates and support beams, which may result in roof damage. In an extreme event, roof plates can tear away at the roof/shell juncture or collapse. Although damage to the tank is possible, total collapse and loss of content because of inadequate freeboard is unlikely, in part, due to the time it takes for the wave to fully load/unload the structural elements.

Page 742 of 1105 ends

City of Fairfield Condition Assessment
July 2023 Page 9
One simple solution to the lack of freeboard would be to lower the operating height of the water level to allow for adequate freeboard. If this approach is not acceptable from an operations standpoint, another alternative is to raise the roof of the reservoirs by a few feet to create adequate freeboard.

Page 743 of 1105 ends

ATEEM Electrical Assessment
Appendix C

Page 744 of 1105 ends

Reservoir Age Functionality Age Functionality Age Functionality Age Functionality Age Functionality Age Functionality Age Functionality Cement Hill 4 3 3 3 1 1 1 1 5 4 1 3 4 4
Eastridge 3 3 4 3 5 4 1 1 4 3 4 3 4 3
Gold Ridge 4 4 4 4 5 4 2 2 4 3 1 2 N/A N/A
Mangels 4 3 4 3 5 4 1 1 4 2 4 3 N/A N/A
Martin Hill 3 3 4 3 3 3 1 1 4 3 4 3 N/A N/A
Nelson Hill 3 3 4 3 1 1 4 3 3 2 Submersible not accessible 2 1 Rancho Solano 3 4 3 4 4 5 4 1 1 4 3 Submersible not accessible N/A N/A Rolling Hills 5 4 4 3 5 4 1 1 2 2 4 3 N/A N/A
Ranking:

Notes:

Fairfield Reservoir Condition Assessment
Utility Service Panels PLC Radio Lighting Level Transmitter Flowmeter Martin Hill Micrologix 1400 PLC has recently been discontinued. Components are still available and it should be possible to continue maintaining the PLC; however, it will eventually need to be replaced.

At Rancho Solano 3, the power meter pedestal was not found; unclear how power is getting to the site.

At Nelson Hill, the Industrial Gateway communications router is not operating consistently; staff is investigating.

At Rolling Hills, water is coming out of the pedestal conduit and flowing onto the ground. Algae is growing on the wet surfaces. This situation should be corrected as soon as possible. 1 = New and/or Works As Expected; 5 = Immediately Replace/Does Not Work Allen-Bradley Model 5/20 PLCs (at Eastridge, Gold Ridge, Mangels, Rancho Solano 3, and Rolling Hills) should be replaced immediately. They are past their useful life and replacements parts are only available via third party vendors.

A number of sites have outdoor receptacles that have missing covers.

Eastridge site is subfed from a local pump station. PLC communicates via blue hose cable to the pump station PLC. Any change to either PLC will require replacement of the blue hose with more modern technology.

The Goldridge level transmitter is located within PLC control panel. Because the level transmitter is connected to a pressure tap, there is effectively a water line into the panel. The level transmitter should therefore be relocated. In addition, the electrical panels are subject to direct sunlight and steps should be taken either to shade the panels or otherwise protect them from sun exposure.

Mangels has old washdown pump starter panel in larger overall panel. The pump no longer is in service. 1 - Immediate Replace
1 - Doesn't Work Appendix C - ATEEM Reservoir-Summary (JPM revisions).xlsx 5 -New

Page 745 of 1105 ends

OSHA Compliant Fall Protection Systems
Appendix D

Page 746 of 1105 ends

6 I
3M™ DBI-SALA®
Davit Arm System Components
Variable offset davits are designed for use where multiple offset masts are required. The variable offset masts may be equipped with front mounted and/or back mounted winches or Self-Retracting
Lifelines (SRLs) and feature an anchor point rated up to 5,000 lbs. (22 kN). For applications with
overhead clearance restrictions, the adjustable
height of the variable offset masts can
eliminate the need for custom length masts
and mast extensions. Quick-connect/release
pins allow for fast and easy setup, dismantle
and transport.

Winch
Davits can be equipped with both primary
and secondary (back-up) mechanical
devices for added flexibility. Retrieval
winches can be used in conjunction with
a retrieval SRL or fall protection system to
raise and lower personnel and equipment.

Quick-mounting brackets
Simple detent-style winch mounting
brackets make installation fast and efficient.
(See page 16 for options.)
Retrieval SRL
Retrieval SRLs offer fall
protection as well as emergency
retrieval for non-entry rescue.

Lower mast
extensions
Allow the user to
adjust the overall
anchorage height
of the system.

Base options
Several portable and fixed base options are
available for complete versatility.
3 4
1 2
3 4
5 Variable offset mast
Adjustable length of davit ensures
lifelines are always centered over
confined space.

Built-in pulleys
Route lifelines of two mechanical
devices for smooth, efficient
operation.

Fall arrest anchorage
Up to a 5,000 lb. (22 kN) rated
anchor point for fall arrest device.

Adjustable height
Eliminates the need
for custom length
masts and extensions.
6 7
8 9
2 1
5 9
6 7
8 Permanent fixed base davit socket Page 747 of 1105
I 9
Davit Arms - One Piece Adjustable Offset Davit Masts
Configurable Davit Systems
8518382
Weight:
31 lbs. (14.1 kg)66 in.–76 in. (167.6 cm–193 cm)

11.5 in.–27.5 in.
(29.2 cm–69.9 cm)

11.5 in.–27.5 in.
(29.2 cm–69.9 cm)

11.5 in.–27.5 in.
(29.2 cm–69.9 cm)
8518383
Weight:

30.75 lbs. (13.9 kg)
8518384
Weight:

43.2 lbs. (19.6 kg)
8518385
Weight:
40 lbs. (18.1 kg)
8518386
Weight:

43.5 lbs. (19.7 kg)
8518387
Weight:
50 lbs. (22.7 kg)
8518001
Weight:

27.1 lbs. (12.3 kg)
8518006
Weight:

31.1 lbs. (14.1 kg)
8518509
Weight:

14.15 lbs.(6.4 kg)
8518002
Weight:

17.6 lbs. (8 kg)
8518003
Weight:

19.75 lbs. (9 kg)
8518004
Weight:

24.15 lbs. (11 kg)
Davit Arm -
Adjustable Offset Upper Davit Masts Lower Davit Mast Extensions 33 in.–43 in. (83.8 cm–109.2 cm)

11.5 in.–27.5 in.
(29.2 cm–69.9 cm)
21 in.
(53.3 cm)
33 in.
(83.8 cm)
45 in.
(114.3 cm)
57 in.
(144.8 cm)

36.5 in.–54.5 in. (92.7 cm–138.4 cm)

23.5 in.–42.5 in.
(59.7 cm–108 cm) 78 in.–88 in. (198.1 cm–223.5 cm)
90 in.–100 in. (228.6 cm–254 cm)

69.5 in.–87.5 in. (176.5 cm–222.2 cm)

23.5 in.–42.5 in.
(59.7 cm–108 cm)

23.5 in.–42.5 in.
(59.7 cm–108 cm)

23.5 in.–42.5 in.
(59.7 cm–108 cm)

81.5 in.–99.5 in. (207 cm–252.7 cm)

93.5 in.–111.5 in. (237.5 cm–283.2 cm)
(Includes winch mount bracket)
Combine these adjustable offset upper davit masts
with up to two lower mast extensions to increase the
davit height. Consult the compatibility charts.

NOTE: Please reference compatibility chart on pages 24–25 for approved configurations, or visit go.3M.com/ConfinedSpaceCompatibilityChart for an updated list.

A
Anchors I Vertical Entry Solutions

Page 748 of 1105 ends

I 31
3M™ DBI-SALA® Sealed-Blok™ vs 3M™ DBI-SALA® Ultra-Lok™
Maximum
Capacity
Maximum
Lifeline Length
Lifeline Type
RSQ Available
Technora® rope Galvanized Stainless steel
Sealed-Blok™ 420 lbs. (190.5 kg) 175 ft. (53.3 m) ■ ■ ■ ■ Ultra-Lok™ 310 lbs. (140.6 kg) 50 ft. (15.2 m) ■ ■
Retrieval SRLs
Model #
3401025
Mounting Bracket for Sealed-Blok™ Retrieval SRL
Fits all sizes of Sealed-Blok™ Retrieval SRL.

Accessories
Cable Type SealedBlok™
SealedBlok™
Without
Bracket
SealedBlok™/ RSQ
Without
Bracket
Ultra-Lok™ 30 ft.
(9.1 m)
50 ft.
(15.2 m)
55 ft.
(16.8 m)
85 ft.
(25.9 m)
130 ft.
(39.6 m)
175 ft.
(52.5m)
Galvanized steel
■ 3400853 3400923 3400871 3400976
■ 3400850 3400920 3400870 3400975 3400660
■ 3400940 3400910 3401002
■ 3501102
Stainless steel
■ 3400858 3400926 3400882 3400987
■ 3400852 3400922 3400874 3400979 3400661
■ 3400942 3400912 3401004
■ 3501103
Technora® rope ■ 3400840 3400843
Retrieval
Ultra-Lok™
SRL
Retrieval
Sealed-Blok™
SRL
Retrieval
Sealed-Blok™

SRL - RSQ
3401025
3M™ DBI-SALA® Sealed-Blok™
Self-Retracting Lifelines with
Retrieval incorporate a concept that
separates all dynamic components,
including the motor spring and
break, from foreign elements
such as grease, moisture and dirt.

Constructed from heavy-duty,
corrosion-resistant materials, the
sealed design meets IP69K rating.
• Available with RSQ Dual-Mode
Design—allows users to select
either standard fall arrest mode
or automatic descent mode.
• Available lengths ranging from
30 ft (9.1m) to 175 ft (53.3m).
• IP69K Sealed Rating.
3M™ DBI-SALA®
Ultra‑Lok™ SelfRetracting Lifelines
with Retrieval are
rugged, yet extremely
lightweight and
superbly engineered
devices you can
count on for safety,
efficiency and comfort.
• Available in 50 ft
length.

Connectors I Winches I Retrieval SRLs
C

Page 749 of 1105 ends

26 Help to make your structures safe and
accessible. Optional configurations
include welded or bolted, straight or
curved ladders, wood, concrete or steel
structures and a variety of rung clamp
sizes and styles. These systems are a
versatile and economical solution for
many applications.
1 Standard top bracket
Galvanized top bracket with mounting
hardware. For systems up to 499 ft.
(152 m) high, fits up to 1-1/8 in. (2.85 cm)
rung diameter and attaches to three rungs.

Includes built-in energy absorber.
2 Standard bottom bracket
Fits up to 1-1/8 in. (2.85 cm) rung diameter
and attaches to two rungs. Galvanized
bottom bracket includes built-in
tension indicator.
3 Cable guide
Non-metallic cable guide with mounting
hardware. For systems up to 199 ft.
(60.6 m), fits up to 1-1/8 in. (2.85 cm)
rung diameter. Recommend one every
25 ft. (7.6 m)
4 Cable lifeline
Galvanized cable, 3/8 in. (9.5 mm)
diameter, 1 x 7 type. Last three digits in
part number indicate length.

5 Lad-Saf X3 Detachable
Cable Sleeve
Climbing sleeve for better climbing
performance and fall protection.

Easy to climb
The Lad-Saf X3 Detachable Cable
Sleeve automatically follows the
climber during ascent or descent.

In the event of a fall, the sleeve
immediately locks onto the cable
and remains locked until the user
can regain their footing.

Tension indicator
Integrated tension-indicating bottom
bracket takes the guesswork out
of installation.

Customizable
Hundreds of different brackets, styles
and configurations to suit almost
any application.

Corrosion-resistant
construction
Galvanized and stainless steel
construction stands up to harsh
environments for added longevity.

Shock-absorbing design
Integrated shock-absorbing top
bracket reduces forces imposed
on ladder structure during a fall.

Protected from wear
Intermediate cable guides help
prevent cable wear against the ladder
while permitting the climber to
bypass without disconnecting.
3M™ DBI-SALA® Lad-Saf™ Flexible Cable Ladder
Safety Systems
5 4
3 2
1

Page 750 of 1105 ends

3M™ DBI-SALA® 3M.com/FallProtection 800-328-6146 (Opt. 1) 27 A Vertical Systems
6100090
3M™ DBI-SALA® Lad-Saf™
Bottom Bracket
Standard galvanized bottom bracket
with mounting hardware. Fits up to
1-1/8 in. (2.85 cm) rung diameter,
attaches to two rungs, built-in
tensioning device.
6100400
Lad-Saf Cable Guide
Non-metallic cable guide with
mounting hardware. For systems
up to 199 ft. (60.6 m), fits up to
1-1/8 in. (2.85 cm) rung diameter. 3M
recommends one every 25 ft. (7.6 m)
6100515 Cable Guide (L-shaped) and
hardware for systems over
200 ft. (61 m)
Lad-Saf Cable Lifeline
Durable high strength steel
construction. Galvanized
construction stands up to harsh
environments for maintenance
free longevity.
6116280
Lad-Saf Top Bracket
Standard galvanized top bracket with
mounting hardware. For systems up
to 499 ft. (152 m) high, fits up to
1-1/8 in. (2.85 cm) rung diameter,
attaches to three rungs, built-in
energy absorber.
6116410 Standard Top Bracket and
hardware for systems over
500 ft. (152.4 m)
6160054
Lad-Saf X3 Detachable
Cable Sleeve
For use with 3/8 in. (9.5 mm)
diameter 1 x 7 or 7 x 19
solid core cable. Comes with
2000112 carabiner. Meets
OSHA and ANSI standards.
6160030
Lad-Saf X2 Detachable
Cable Sleeve
Sleeve with carabiner, dual
independent locking system,
fits 3/8 in. (9.5 mm) and 5/16 in.
(8 mm) diameter 1 x 7 or 7 x 19
solid core cable.
6110XXX 6152XXX 6130XXX 6154XXX
Diameter 3/8 in. (9.5 mm) 3/8 in. (9.5 mm) 3/8 in. (9.5 mm) 3/8 in. (9.5 mm) Strand 1 x 7 1 x 7 7 x 19 7 x 19
Steel Galvanized Stainless Galvanized Stainless
Preformed Left, Regular Lay Left, Regular Lay Right, Regular Lay Right, Regular Lay Compliance ASTM A475 ASTM A368 RR-W-410 RR-W-410
Breaking strength 15,400 lbs. minimum 18,000 lbs. minimum 14,400 lbs. minimum 12,000 lbs. minimum Cable Lifeline general specifications and materials
Last three digits in part number indicate length.

Coming Soon:
3M™ DBI-SALA® Lad-Saf™
Flexible Cable Vertical
Safety System
Redesigned to streamline installation
with up to 72% fewer loose
components compared to current
generation. ANSI Z359.16 compliant.

System Kits
System Kits include 6116280
Top Bracket, 610090 Bottom
Bracket, 3/8 in. 1 x 7 galvanized
cable with designated length and
cable guides where required.
6100897 17 ft. Lad-Saf System Kit
6100898 20 ft. Lad-Saf System Kit
6100877 30 ft. Lad-Saf System Kit
6100909 45 ft. Lad-Saf System Kit
6100876 100 ft. Lad-Saf System Kit

Page 751 of 1105 ends

3M™ DBI-SALA® 3M.com/FallProtection 800-328-6146 (Opt. 1) 29 A Vertical Systems
Ladder Accessories
Steel Pole Ladder Safety System
Angle iron, clamp-on,
and steel pole weld-on
systems also available.

Call us today.
6116261
Top Bracket for Steel Pole
Bolt-on for monopole towers.
6116250
Top Bracket for Steel Pole
Weld-on for monopole towers.
6116336
Grab Bar Extension
Slides into Top Bracket (6116054)
of fixed ladder safety system
and provides the user with a
tie off point (for lanyard) when
connecting or disconnecting
from the system’s lifeline.
6116054
Top Bracket Assembly
For use with 6116336 (replaces
standard 6116280 Top Bracket).
6116026
Ladder Anchor Post
Galvanized removable
extension with eye-bolt
anchor to attach 3-way SRL.
6116027
Galvanized Bottom
Mounting Bracket
Attaches 6116026
to ladder.
5901980
Ladder Gate
Designed to help protect
you from the dangers (and
liability) of unauthorized
ladder access.

Fits ladder widths up to
20 in. (50.8 cm). Mounting
hardware included.

Aluminum construction
8 ft. (2.4 m) height x 36 in.
(91.4 cm) width.

Page 752 of 1105 ends

30 5
6 4
3 2
1 The Rigid Rail System consists
of top and bottom entry/exit
gates, rail joints and multiple
mounting bracket options
designed to mount the rigid
aluminum rail to the structure.

You can configure to an existing
ladder or customize a system
with integrated ladder pegs
when no ladder exists. Various
clamps are available to attach
to almost any structure.

Shock-absorbing design
Integrated energy absorber
reduces forces imposed on
system and worker.

Easy to climb
Automatically follows the user
and locks in the event of a fall.

Ladder rung clamps
A variety of rung clamps
designed for installation at
multiple anchor points along
the system length.

Customizable
Different clamps and
configurations available.

Corrosion-resistant
construction
Stands up to harsh environments
for added longevity.
1 6000352
Top Ladder Rail Gate
Allows user to easily attach shuttle
to the system and helps prevent
accidental removal from the system.
2 6000120
Ladder Rung Clamp
Attaches rail to ladder structure. Use
within 1 ft. (0.3 cm) of rail splice and
one at least every 5 ft. (1.5 m)
3 6000033
Standard Rail
Anodized extruded aluminum rail
x 6.56 ft. (2 m)
6000031 3.25 ft. (1 m) Rail Section
6000032 9.84 ft. (3 m) Rail Section
4 6000100
Rail Joint
Attaches two rail sections together.
5 6000377
Shuttle
Climbing shuttle automatically
follows user and locks onto rail
during a fall.
6 6000375
Bottom Standard
Rail Gate
Allows user to easily attach shuttle
to the system and helps prevent
accidental removal from the system.
3M™ DBI-SALA® Rigid Rail Ladder Safety Systems
Standard Ladder

Page 753 of 1105 ends

Water Distribution System Condition and Risk
Assessment
Appendix F

Page 754 of 1105 ends

2020 Research Park Drive
Suite 100
Davis CA 95618
530.756.5905 phone
530.756.5991 fax
westyost.com

TECHNICAL MEMORANDUM
DATE: March 19, 2024 Project No.: 268-60-22-20
SENT VIA: EMAIL
TO: Mike Hether, PE
Assistant Public Works Director – Utilities
CC: George Shimboff
Stuart Hamilton
FROM: Anne Girtz, PE, RCE #91396
Austin Oerding
REVIEWED BY: Mike Zacharia, PE, RCE #43225
Amy Kwong, PE, RCE #73213
SUBJECT: Water Distribution System Condition and Risk Assessment

INTRODUCTION
The City of Fairfield (City) has retained West Yost to develop its 2023 Public Utility Master Plan (PUMP).

Task 6 for the PUMP describes a Water Distribution System Assessment (Assessment) to evaluate the condition of the City’s existing water distribution system and to make recommendations for improvements. The following is a summary of the Task 6 Assessment scope of services:
• Perform a desktop condition assessment of the water distribution system, including pipeline, valve, and service lateral assets.
• Develop an asset registry for the water distribution system, review background information, and perform workshops with City staff.
• Utilize the City’s existing risk framework to develop risk factors for each water distribution system asset type and assess risk for each asset.
• Based on the desktop condition and risk assessment results, develop a rehabilitation and replacement plan for pipelines, valves, and service laterals that can be incorporated into the Near-Term (2030) and Long-Term (2050) CIP.

This technical memorandum (TM) summarizes the methods, findings, and recommendations that comprise the Assessment effort, and is organized into the following sections:
• Asset Registry
• Condition Assessment
• Risk Assessment
• Rehabilitation and Replacement Plan

Page 755 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 2 ends

N-C-268-60-22-20-WP-TM5

ASSET REGISTRY
In order to perform the condition and risk assessments, a comprehensive listing of the City’s water distribution system assets was required. The City provided GIS databases which included asset information such as location, size, type, material, and installation year. This information was used as the basis for the assessment.

Assets included in the assessment were:
 Pipelines ranging from 4-inches to 48-inches in diameter.  Valves greater than or equal to 24-inches in diameter, including both transmission main valves and facility valves. Facility valves are defined as valves associated with a pump station or reservoir facility and were identified by their location in the system and (e.g., valves that were not immediately adjacent to a transmission pipelines). Transmission valves are defined as valves attached to a distribution system pipeline greater than or equal to 24-inches and were identified by their adjacency to those pipelines.
 Service laterals greater than or equal to 3-inches in diameter (the City did not have location data for service laterals smaller than 3-inches in diameter) Table 1 presents a summary of the assets included in the final water distribution system asset registry.

Table 1. Water Distribution System Asset Registry – Count of Asset Types Asset Type Count
Pipelines 8,733 segments (391 miles)
Transmission Valves (≥24”) 300
Facility Valves (≥24”) 53
Service Laterals (≥3”) 3,746
Total 12,832

CONDITION ASSESSMENT
The desktop condition assessment was performed by using year of installation data provided by the City and an estimated useful life (EUL) to determine a remaining useful life (RUL) for each asset.

Asset EUL is the time that an asset provides valued service, after which it does not meet its intended service level. End of life is not necessarily indicative of catastrophic failure, and in most cases an asset can still hold functionality (but with a reduced level of service and/or reliability). Asset RUL can be estimated by comparing the actual age of assets (determined from installation date) to a standard useful life expectancy. In the absence of detailed condition or performance data, this approach provides an initial determination of assumed condition and can be used to project estimated renewal needs.

Standard useful life expectancies are documented by the American Water Works Association, Water Environment Research Foundation, in addition to other industry associations. EUL expectancies were developed for the distribution system assets using these industry standards and input from City staff. Each asset type within the water distribution system was assigned an estimated useful life, as presented in Table 2.

Page 756 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 3 ends

N-C-268-60-22-20-WP-TM5
Table 2. Estimated Useful Life Values
Asset Type Estimated Useful Life, years
Pipelines and Service Laterals (by Material)
Asbestos Cement Pipe (ACP) 90
CS 75
DIP 100
GALV 95
Pre-Stressed Concrete Cylinder Pipe (PCCP) 75
Polyvinyl Chloride (PVC) 100
Steel 90
Steel/CPP (Reinforced Concrete Pressure Pipe) 100
Steel/AWWA 90
Copper 50
Transmission Valves 1/3 of Pipeline EUL
Facility Valves 20
RUL was calculated for each asset by subtracting the asset age (how long the asset has been installed) from its estimated useful life (EUL) – see Equation 1. Asset age was calculated based on the installation date and current year as 2023. For example, an asset with a 50-year estimated useful life that has been in service 35 years would have a RUL of 15 years. RUL can also be expressed in terms of percent RUL, that is, the percent of useful life that remains for the – see Equation 2.

Eqn. 1: RUL = EUL – age
Eqn. 2: Percent RUL = RUL / EUL
Desktop Assessment Analysis
Asset RUL results were grouped into four classes for data visualization purposes. Classes range from Class A, which includes newer assets in the first 25 percent of their useful life expectancy/assets that are expected to be in new or like new condition, to Class D, which includes assets in the last 25 percent of their useful life expectancy/assets that are expected to be in poorer condition. Table 3 presents the percent RUL categories, associated classification, and expected condition rating.

Note that this desktop analysis uses age and estimated useful life values to estimate an expected condition. In the absence of condition or performance data, this approach provides an initial determination of assumed condition but does not provide a conclusive picture of actual asset condition.

For pipe and valve assets, end of useful life is not necessarily indicative of catastrophic failure, and in most cases an asset can still hold functionality (potentially with a reduced level of service) when it has reached the end of its useful life.

Page 757 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 4 ends

N-C-268-60-22-20-WP-TM5
Table 3. RUL Categories
Percent RUL Class Expected Condition Rating
75-100 A Like New or New
50-75 B Good
25-50 C Fair
0-25 D Poor
Figures 1 through 3 present a graphical representation of RUL class for each asset type. This information provides a snapshot view of the condition of the City’s water distribution system assets and where future R&R may be required. In general, the City’s pipelines and service laterals are generally in good to fair condition based on the RUL estimation and classification. The City’s transmission and facility valves are mostly in poor condition due to their older age and relatively short useful life of valves (for transmission valves, a maximum 33-year EUL, based on pipeline EUL; and for facility valves, a 20-year EUL).

Figure 1. Pipeline RUL Class by Length (miles) and Percent of Total Pipeline Length

83.04 160.74
135.45

11.87 0%
5%
10%
15%
20%
25%
30%
35%
40%
45%
-
20 40
60 80
100
120
140
160
180
A B C D Relative Total, Percent Length, miles
RUL Class

Page 758 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 5 ends

N-C-268-60-22-20-WP-TM5
Figure 2. Service Lateral RUL Class by Count and Percent of Service Laterals ≥ 3-inch Figure 3. Valve RUL Class by Count and Percent of Valves ≥ 24-inch

821
1431
1363
131
0%
5%
10%
15%
20%
25%
30%
35%
40%
45%
0 200
400
600
800
1000
1200
1400
1600
A B C D Relative Total, Percent Count
RUL Class
25 22
38 268
0%
10%
20%
30%
40%
50%
60%
70%
80%
0 50
100
150
200
250
300
A B C D Relative Total, Percent Total Count
RUL Class

Page 759 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 6 ends

N-C-268-60-22-20-WP-TM5

RISK ASSESSMENT
The risk assessment considers both likelihood of failure (LOF) ratings and consequence of failure (COF) ratings to quantify the risk associated with each asset. The risk assessment methodology and results presented in this section are consistent with the results presented in the Condition Assessment section above and with the City’s 2023 Pump Station Asset Management Plan. These results are used as the basis for prioritization of the Rehabilitation and Replacement Plan, described later in this TM. Rehabilitation and replacement project costs will be presented in Chapter 9 of the PUMP Report.

Key topics addressed in this section include:
 Risk Methods
 Pipeline Risk Results
 Service Lateral and Valve Risk Results
The general approach used in the risk assessment is illustrated in Figure 4 (pipelines) and Figure 5 (service laterals and valves).

For pipelines, ratings for LOF and COF are assigned for each individual pipeline. Pipeline risk is then calculated based on those asset LOF and COF scores. For valves and service laterals, a rating for LOF is assigned for each individual asset. The COF for valves and service laterals is inherited from the adjacent or connecting pipeline based on the assumption that the pipeline appurtenances have a similar consequence of failure as its associated pipeline. Valve or service lateral risk is then calculated based on the asset LOF score and adjacent/associated pipeline COF score.

Figure 4. Pipeline Risk Assessment Methodology
Figure 5. Service Lateral and Valve Risk Assessment Methodology

Pipeline Risk
Asset LOF Asset COF
Service Lateral / Valve Risk
Asset LOF Pipeline COF

Page 760 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 7 ends

N-C-268-60-22-20-WP-TM5
Risk Methods
This section describes the methods used to perform the LOF and COF analyses and to determine the resulting risk level for individual pipeline, service lateral, and valve assets assessed for the PUMP.

Pipeline LOF
The asset LOF analysis considers the probability that a failure of a given asset will occur. The analysis considers LOF as two factors, Percent of Remaining Useful Life (Eq. 2 in the Condition Assessment section) and Percent Likelihood of Failure from the City’s Fracta model. Where percent RUL could not be calculated due to lack of data, only LoF from the Fracta model was used. Table 4 describes what each LOF factor takes into consideration.

Table 4. Criteria Used for Asset LOF Evaluation
Criteria/Factor Description
Percent of Remaining
Useful Life
This factor takes into account the fact that older assets are more likely to fail than newer ones due to the age of materials and wear from repeated use. The percent of remaining useful life was determined by comparing installation date to the industry standard useful life for each asset, as discussed in the Condition Assessment section of this TM. Percent RUL = (EUL-age)/EUL.

Percent Likelihood of
Failure (Fracta)
The City had previously undertaken a likelihood of failure analysis with Fracta, Inc., which uses machine learning to develop a condition and risk rating of drinking water distribution pipelines.

Fracta assigns a Likelihood of Failure (LoF) condition assessment score to every pipe segment based on various risk factors and break history using both City of Fairfield data as well as data available for pipelines with similar environment criteria across the world. After gathering the historical pipe break data, relevant environmental variables are factored into the algorithm such as soil, elevation, proximity to water, railroads and more.

Fracta’s Likelihood of Failure (LoF) is the condition assessment score given to each pipeline asset in the water distribution system. It can be interpreted as the percent chance of failure for a pipe. The LoF percentage is the LoF for the next 12 months.

The LOF factors above are translated into numeric rankings of 1 to 10, with 10 indicating the highest LOF.

The Percent of Remaining Useful Life factor governed for 96 percent of the pipelines – this is due to the very low probability of failure within the next 12 months predicted through the Fracta model.

An overall LOF score is determined by taking the maximum value of the two ratings, so each asset will have an overall LOF score of between 1 and 10. The factors and their range of potential ratings for each category are presented in Table 5.

Table 5. Distribution System Asset LOF Rating Factors
Criteria/Factor
Rating
1 2 3 4 5 6 7 8 9 10
Percent of
Remaining
Useful Life
100-70 71-63 62-55 54-47 46-39 38-31 30-23 22-15 14-8 7-0 Fracta Percent
Likelihood of
Failure
<50 51-60 61-70 71-78 79-85 86-90 91-93 94-96 97-99 >99

Page 761 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 8 ends

N-C-268-60-22-20-WP-TM5
Service Lateral and Valve LOF
Fracta data was not available for service laterals and valves, so the LOF for these assets was evaluated solely based on percent of remaining useful life.

Asset COF
The COF analysis considers the impact that an asset failure may have on the water system as a whole, the City, and the surrounding community. As described previously, the COF was evaluated for the pipelines; then all service laterals and valves connecting or adjacent to that pipeline inherit that same COF score.

This approach assumes that the pipeline appurtenances have a similar consequence of failure as its associated pipeline. The criteria considered in determining the COF are presented in Table 6.

Table 6. Criteria Used for Asset COF Evaluation
Category Criteria/Factor Description
Operating
Ability Ability to Maintain Service
Operating ability considers the effect on the water system and the customers if the pipeline fails. Failure will have a varying degree of impact on the ability of the system to deliver water depending on the size and location of the asset.

Larger pipelines or pipelines with existing capacity deficiencies indicate a larger potential consequence.

Difficulty to
Repair
Street Type / Difficult
Area Identified by City
The time and/or resources required to repair or replace an asset depend on the location and accessibility of the asset. An easy repair or replacement is defined as being located on a local street with little vehicle and foot traffic and little disruption to the public. A difficult repair or replacement would be located on a highway, on-ramp, railway crossing, or area otherwise identified as challenging by the City.

The COF factors shown in Table 6 were translated into numeric rankings of 1 to 5, with 5 indicating the highest or worst consequence. Each pipeline was evaluated for the two factors, then added together, with a resultant overall COF score between 2 and 10 using the following formula:

Overall COF = Operating Ability (COF1) + Difficulty to Repair (COF2) This pipeline COF is assigned to all service laterals and valves adjacent to that pipeline. The factors and their range of potential ratings for each category are presented in Table 7.

Table 7. Distribution System Asset COF Rating Factors
Consequence Factor
Rating (1 being the lowest, 5 being the highest)
1 2 3 4 5
Operating
Ability
Ability to
Maintain
Service
Distribution
Mains
(<12-inch)
Distribution
Mains
(≥12-inch)
--
Transmission
Mains (≥24inch)
Cannot meet
fire flow
requirement(a)
Difficulty to
Repair
Street Type /
Difficult Area
Identified by
City
Local Collector Arterial
Highway,
Freeway, ramp,
railway crossing
Other difficult to
access, identified
by City(b)
(a) There were no existing fire flow deficiencies identified during this assessment; however, the criterion is left in place as a metric to be used in future evaluations.
(b) City provided a list of approximately 50 locations, by pipeline, that were considered areas that required complex repairs.

Page 762 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 9 ends

N-C-268-60-22-20-WP-TM5
Risk Score Calculation
Upon determining all the asset LOF and COF scores, a risk score is calculated for each pipeline, service lateral, and valve using the following formula:

Risk Score = Asset LOF Score x Asset COF Score
Risk Results
By plotting the LOF and COF scores of each asset against each other, an overall risk level was assigned to each asset. Risk levels are prioritized into five risk levels: Low, Medium-Low, Medium, Medium-High, and High, each of which is color-coded in Table 8. These risk levels are assigned to the various cells using best engineering judgment to determine which combinations of scores warrant the highest levels of concern versus those that warrant lesser levels of concern. This risk matrix is in alignment with the matrix developed in the City’s 2023 Pump Station Asset Management Plan and was also used for other asset type assessments within the PUMP.

Table 8. PUMP Risk Matrix
COF Score
2 3 4 5 6 7 8 9 10 LOF Score
1 2
3 4
5 6
7 8
9 10
Risk Levels Low Medium-Low Medium Medium-High High

Page 763 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 10 ends

N-C-268-60-22-20-WP-TM5
Pipeline Risk Results
The pipeline risk assessment results are summarized in Table 9, which lists the total length and percentage of pipelines that fall in each risk level. The majority of the pipelines (84 percent) fall into the Low or Medium-Low risk levels. The pipeline risk levels are presented spatially on Figure 6.

Table 9. Pipeline Risk Level Results Summary
Risk Level Length of Pipelines, feet Length of Pipelines, miles Percent of Total Low 940,745 178.2 45.6
Medium-Low 788,872 149.4 38.2
Medium 304,161 57.6 14.7
Medium-High 31,289 5.9 1.5
High 0 0 0
Total 2,065,068 391.1 100%
Service Lateral Risk Results
The service lateral risk assessment results are summarized in Table 10, which lists the service laterals (greater than or equal to 3-inches diameter) and percentage of the total that falls in each risk level. The majority of the service laterals (85 percent) fall into the Low or Medium-Low risk levels.

Table 10. Service Laterals (≥ 3-inch) Risk Level Results Summary Risk Level Count of Service Laterals Percent of Total
Low 1,810 48.3
Medium-Low 1,377 36.8
Medium 546 14.6
Medium-High 13 0.3
High 0 0
Total 3,746 100%
Valve Risk Results
The valve risk assessment results are summarized in Table 11, which lists the number of valves (greater than 24-inch diameter) and percentage of the total that falls in each risk level. The majority of the valves (77 percent) fall into the Medium-High or High-risk levels.

Table 11. Valve (>24-inch) Risk Level Results Summary
Risk Level Number of Assets Percent of Total
Low 25 7.1
Medium-Low 18 5.1
Medium 40 11.3
Medium-High 157 44.5
High 113 32
Total 353 100%

Page 764 of 1105 ends
Page 765 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 12 ends

N-C-268-60-22-20-WP-TM5

REHABILITATION AND REPLACEMENT (R&R) PLAN DEVELOPMENT
A rehabilitation and replacement (R&R) plan was developed based on the condition and risk assessment results presented above. The condition assessment results were used to identify assets that are likely in poor condition and may be in need of rehabilitation or replacement. The risk assessment results were used to prioritize these assets within the framework of the Near-Term and Long-Term planning timeframes.

Each of the asset types, and how they were incorporated into the R&R plan, is discussed below.

Pipelines
 The oldest pipelines have a RUL of 19 years (i.e., are not expected to require replacement for 19 years, in year 2042)
 No pipelines were assessed to be High risk. 5.9 miles (51 segments) of pipeline were assessed to be Medium-High Risk (1.5% of total pipeline length) Service Laterals (≥3-inch)
 The oldest service laterals have a RUL of 19 years (i.e., are not expected to require replacement for 19 years, in year 2042)
 No service laterals were assessed to be High risk. Thirteen service laterals were assessed to be Medium-High Risk
The City’s pipelines and ≥3-inch service laterals are relatively new and hold a relatively low risk, with the lowest RUL at 19 years. For these reasons, replacements for pipelines and ≥3-inch service laterals are not recommended within the Near-Term (2030) timeframe. Starting in 2042, through the end of the Long-Term timeframe (2050), 20.1 miles of replacement are expected due to assets reaching end of EUL.

These 2042-2050 replacements should be prioritized by risk. in general, service laterals should be replaced when their adjacent pipeline is replaced.

The City provided anecdotal information that the service laterals (of all sizes) in certain “Priority Areas” of the City should be prioritized for replacement. Because service lateral information was not available spatially, meters were used to estimate the number of service laterals (all sizes) within the Priority Areas.

These service lateral replacements were distributed within the Near-Term timeframe (over 6 years, from 2025 to 2030). Note that only service laterals ≥3-inch were included in the condition and risk assessment sections of this TM, but the R&R will include recommendations for all size service laterals. The extents of the four Priority Areas were provided by the City and shown in Figure 7.

The City has been proactively replacing small diameter pipelines (≤6-inch) throughout their system in areas where these pipelines present capacity issues (e.g., courts with no hydrants). Based on the City’s current GIS, there are 9,075 feet of 4-inch pipeline and 135,528 feet of 6-inch pipeline remaining in the system. The City expects there is actually less than 1,000 feet of remaining 4-inch pipeline and acknowledged that the GIS is out of date. As of March 2024, the City was still in the process of updating their GIS to reflect pipeline upgrades. It was agreed that small diameter pipelines would only be recommended for replacement if they present a hydraulic deficiency. The City will continue to update their GIS to reflect recent upgrades and for consistency with the hydraulic model.

Page 766 of 1105 ends
Page 767 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 14 ends

N-C-268-60-22-20-WP-TM5
Valves
 252 valves have a RUL of less than or equal to 0 (in year 2025)  113 valves were assessed to be High risk. 157 valves were assessed to be Medium-High Risk The City’s valves are relatively old and higher risk due to primarily to the relatively short useful life of valves (20 to 33 years). Most valves have not been replaced since their adjacent pipeline was installed.

The City repairs or replaces valves reactively but has expressed interest in developing a system-wide valve replacement program. It is recommended all valves with zero RUL (252 valves) are included in replacement budgets within the next 5 years. These 252 valves were prioritized based on input from the City and the risk results. A list of priority valves was provided March 2024 by the City and were selected based on: major crossings (freeways); influent/effluent pump stations; effluent transmission mains from treatment plant; creek/canal crossings; source water flexibility and redundancy; single feed lines. These valve replacements can also be grouped by proximity for construction efficiencies.

Other valves that reach the end of their EUL in the planning timeframes should be budgeted for in the year they reach zero RUL.

Recommended R&R Plan
The R&R plan presented below is a forecast of expected improvements based on the age and expected condition of assets. The exact intervention (i.e., rehabilitation or replacement) and timing should be confirmed through condition assessment studies and/or validation with field and maintenance records.

Until the R&R plan is validated, the forecast should primarily be used for system-wide planning and budgeting (e.g., to estimate dollars per year budgeted for water system R&R). The R&R plan should be reviewed and updated annually, or as new condition or performance data becomes available; this approach should provide the City adequate funding for R&R throughout the Long-Term planning timeframe.

A summary of the proposed R&R plan is presented in Table 12 and Figure 7. Asset listings for each year of the plan are provided in Appendices A-1 (valves) and A-2 (pipelines and service laterals).

Page 768 of 1105 ends

TM – City of Fairfield
March 19, 2024

Page 15 ends

N-C-268-60-22-20-WP-TM5
Table 12. Proposed Water Distribution System R&R Plan
Year Description of Replacement
Length
of
Pipeline
Count of
Service
Laterals Count of Valves
2025
 All service laterals (all sizes) in Priority Area 2.
 Valves already beyond their EUL in Year 2025 and
identified as Priority Valves by the City.
- 208(a)
69 (4 Facility
and 65
Transmission)
2026
 All service laterals (all sizes) in Priority Area 4.
 Valves already beyond their EUL in Year 2025 and
with a High Risk Level
- 769(a)
77 (2 Facility
and 75
Transmission)
2027
 Half of service laterals (all sizes) in Priority Area 3.  Valves already beyond their EUL in Year 2025 and
with a Medium-High Risk Level
- 562(a)
106 ((47 Facility
and 59
Transmission)
2028
 Half of service laterals (all sizes) in Priority Area 3.  Valves with zero RUL in Year 2028 - 562(a) 16 Transmission 2029  Half of service laterals (all sizes) in Priority Area 1. - 718(a) - 2030
(End of
Near-Term)
 Half of service laterals (all sizes) in Priority Area 1. - 719(a) - 2031 - - - -
2032  Valves with zero RUL in Year 2032 - - 1 Transmission 2033 - - - -
2034  Valves with zero RUL in Year 2034 - - 5 Transmission 2035  Valves with zero RUL in Year 2035 - - 15 Transmission 2036-2050
(Long-Term)
 Pipelines and service laterals (≥3”) reaching their
EUL from Year 2036 to 2050 (starts in 2042).
 Valves reaching zero RUL from Year 2036 to 2050
106,332
ft (490
pipes)
257 51 Transmission
(a) Service lateral counts include service laterals of all sizes in Priority Areas shown on Figure 7. Service laterals smaller than 3-inch were not available spatially, so the number of these service laterals was estimated using the number of meters in each Priority Area.

Page 769 of 1105 ends

Proposed Valve R&R

Appendix A-1

Page 770 of 1105 ends

ID Diameter, inch Type CIP Year
WGV-13054 24 Transmission 2025
WGV-13651 24 Transmission 2025
WGV-13158 24 Transmission 2025
WBV-10508 24 Transmission 2025
WGV-15043 24 Transmission 2025
WGV-15078 24 Transmission 2025
WBV-10324 30 Transmission 2025
WBV-10297 30 Transmission 2025
WBV-10325 30 Transmission 2025
WBV-10496 30 Transmission 2025
WGV-15020 30 Transmission 2025
WGV-14633 30 Transmission 2025
WBV-10371 30 Transmission 2025
WGV-15019 30 Transmission 2025
WBV-10331 30 Transmission 2025
WBV-10332 30 Transmission 2025
WGV-12614 30 Transmission 2025
WBV-10373 30 Transmission 2025
WBV-10652 36 Transmission 2025
WGV-13107 24 Transmission 2025
WBV-10391 24 Transmission 2025
WGV-13397 24 Transmission 2025
WBV-10615 24 Transmission 2025
WGV-12572 24 Transmission 2025
WBV-10494 30 Transmission 2025
WBV-10406 24 Transmission 2025
WBV-10651 24 Transmission 2025
WBV-10242 36 Transmission 2025
WGV-15060 24 Transmission 2025
WBV-10240 36 Transmission 2025
WGV-13286 24 Transmission 2025
WBV-10377 36 Transmission 2025
WGV-13493 36 Transmission 2025
WBV-10281 36 Transmission 2025
WBV-10392 24 Transmission 2025
WBV-10521 24 Transmission 2025
WBV-10416 30 Transmission 2025
WBV-10491 24 Transmission 2025
WGV-12305 24 Transmission 2025
WGV-14049 24 Transmission 2025
WGV-14047 24 Transmission 2025
WBV-10611 36 Transmission 2025
WGV-13027 36 Transmission 2025
WGV-13325 36 Transmission 2025
WBV-10436 36 Transmission 2025
A-1. Proposed Valve R&R
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment

Page 771 of 1105 ends

ID Diameter, inch Type CIP Year
A-1. Proposed Valve R&R
WBV-10492 36 Transmission 2025
WBV-10437 36 Transmission 2025
WBV-10467 36 Transmission 2025
WBV-10490 36 Transmission 2025
WBV-10357 36 Transmission 2025
WMOV-10006 30 Transmission 2025
WGV-15004 36 Transmission 2025
WBV-10554 36 Transmission 2025
WBV-10540 36 Transmission 2025
WGV-15017 24 Transmission 2025
WGV-15018 24 Transmission 2025
WGV-14040 24 Transmission 2025
WBV-10442 24 Transmission 2025
WBV-10054 24 Transmission 2025
WBV-10409 24 Transmission 2025
WBV-10412 24 Transmission 2025
WBV-10408 24 Transmission 2025
WBV-10410 24 Transmission 2025
WGV-13407 24 Transmission 2025
WGV-13287 24 Transmission 2025
WMOV-10022 36 Facility 2025
WMOV-10011 30 Facility 2025
WMOV-10010 24 Facility 2025
WMOV-10021 30 Facility 2025
WBV-10495 30 Transmission 2026
WBL-10647 30 Transmission 2026
WGV-12969 30 Transmission 2026
WGV-15013 30 Transmission 2026
WGV-15003 30 Transmission 2026
WGV-13032 30 Transmission 2026
WBL-10768 30 Transmission 2026
WGV-15014 30 Transmission 2026
WBV-10657 30 Transmission 2026
WARV-10289 30 Transmission 2026
WARV-10219 30 Transmission 2026
WARV-10283 30 Transmission 2026
WGV-14438 30 Transmission 2026
WBL-10814 30 Transmission 2026
WBL-10765 30 Transmission 2026
WGV-14437 30 Transmission 2026
WBV-10369 30 Transmission 2026
WBV-10656 30 Transmission 2026
WGV-15010 30 Transmission 2026
WGV-15011 30 Transmission 2026
WGV-15059 30 Transmission 2026
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment

Page 772 of 1105 ends

ID Diameter, inch Type CIP Year
A-1. Proposed Valve R&R
WARV-10291 30 Transmission 2026
WBL-10764 30 Transmission 2026
WBV-10658 30 Transmission 2026
WBV-10372 30 Transmission 2026
WBV-10211 24 Transmission 2026
WARV-10094 24 Transmission 2026
WGV-14907 24 Transmission 2026
WGV-15157 24 Transmission 2026
WBV-10682 24 Transmission 2026
WGV-14649 24 Transmission 2026
WBV-10489 24 Transmission 2026
WBV-10045 36 Transmission 2026
WGV-14653 24 Transmission 2026
WGV-19157 24 Transmission 2026
WBV-10253 24 Transmission 2026
WBL-10369 36 Transmission 2026
WGV-13649 24 Transmission 2026
WGV-10138 24 Transmission 2026
WGV-12714 24 Transmission 2026
WGV-12159 24 Transmission 2026
WBV-10153 24 Transmission 2026
WGV-12160 24 Transmission 2026
WGV-14439 36 Transmission 2026
WGV-11396 36 Transmission 2026
WGV-14440 36 Transmission 2026
WBV-10370 36 Transmission 2026
WGV-13152 36 Transmission 2026
WBK-10026 36 Transmission 2026
WGV-12823 36 Transmission 2026
WBL-10766 36 Transmission 2026
WBYV-10002 36 Transmission 2026
WBV-10260 36 Transmission 2026
WBL-10080 36 Transmission 2026
WBL-10532 36 Transmission 2026
WGV-13388 24 Transmission 2026
WBV-10375 36 Transmission 2026
WGV-11578 36 Transmission 2026
WGV-12673 36 Transmission 2026
WBV-10108 24 Transmission 2026
WBV-10343 24 Transmission 2026
WBV-10217 36 Transmission 2026
WGV-11547 36 Transmission 2026
WBL-10773 36 Transmission 2026
WGV-12759 24 Transmission 2026
WBV-10243 24 Transmission 2026
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment

Page 773 of 1105 ends

ID Diameter, inch Type CIP Year
A-1. Proposed Valve R&R
WBK-10044 24 Transmission 2026
WBL-10662 36 Transmission 2026
WGV-11779 36 Transmission 2026
WGV-13255 24 Transmission 2026
WBV-10407 24 Transmission 2026
WBV-10278 24 Transmission 2026
WBV-10279 24 Transmission 2026
WBV-10329 24 Transmission 2026
WBV-10327 24 Transmission 2026
WBV-10666 24 Facility 2026
WCHV-10050 24 Facility 2026
WGV-15162 30 Transmission 2027
WBV-10462 30 Transmission 2027
WARV-10265 30 Transmission 2027
WBV-10307 24 Transmission 2027
WGV-15241 24 Transmission 2027
WGV-13511 24 Transmission 2027
WARV-10002 30 Transmission 2027
WARV-10004 30 Transmission 2027
WBL-10813 30 Transmission 2027
WGV-15012 30 Transmission 2027
WBL-10299 30 Transmission 2027
WBV-10084 24 Transmission 2027
WGV-12314 24 Transmission 2027
WGV-10825 24 Transmission 2027
WBV-10681 24 Transmission 2027
WGV-13396 36 Transmission 2027
WARV-10121 36 Transmission 2027
WBV-10487 24 Transmission 2027
WGV-12007 24 Transmission 2027
WARV-10297 36 Transmission 2027
WBL-10823 36 Transmission 2027
WGV-11165 24 Transmission 2027
WBV-10488 24 Transmission 2027
WGV-13104 24 Transmission 2027
WGV-15242 24 Transmission 2027
WBV-10156 36 Transmission 2027
WGV-13108 24 Transmission 2027
WBV-10650 24 Transmission 2027
WGV-11164 24 Transmission 2027
WGV-14606 24 Transmission 2027
WGV-13103 24 Transmission 2027
WGV-14654 36 Transmission 2027
WGV-10114 24 Transmission 2027
WGV-12142 36 Transmission 2027
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment

Page 774 of 1105 ends

ID Diameter, inch Type CIP Year
A-1. Proposed Valve R&R
WGV-10631 24 Transmission 2027
WBV-10043 36 Transmission 2027
WBV-10486 24 Transmission 2027
WGV-12132 36 Transmission 2027
WARV-10293 36 Transmission 2027
WARV-10296 36 Transmission 2027
WMTV-10010 48 Transmission 2027
WMTV-10011 30 Transmission 2027
WARV-10298 36 Transmission 2027
WGV-15009 36 Transmission 2027
WARV-10008 36 Transmission 2027
WBL-10824 36 Transmission 2027
WGV-11381 24 Transmission 2027
WCV-10010 36 Transmission 2027
WBYV-10001 30 Transmission 2027
WBV-10028 36 Transmission 2027
WGV-14811 30 Transmission 2027
WBV-10029 36 Transmission 2027
WBV-10031 36 Transmission 2027
WBL-10972 36 Transmission 2027
WBV-10032 36 Transmission 2027
WBV-10258 36 Transmission 2027
WBV-10255 24 Transmission 2027
WGV-12250 24 Transmission 2027
WBV-10335 24 Transmission 2027
WBV-10667 24 Facility 2027
WCHV-10041 36 Facility 2027
WCHV-10039 36 Facility 2027
WMOV-10028 24 Facility 2027
WMTV-10003 36 Facility 2027
WCHV-10040 36 Facility 2027
WCHV-10051 24 Facility 2027
WCHV-10038 36 Facility 2027
WBV-10466 30 Facility 2027
WBV-10464 30 Facility 2027
WBV-10463 30 Facility 2027
WBV-10465 30 Facility 2027
WBL-10921 30 Facility 2027
WBV-10617 24 Facility 2027
WBV-10618 24 Facility 2027
WBV-10622 30 Facility 2027
WBV-10619 24 Facility 2027
WBV-10621 30 Facility 2027
WBV-10628 30 Facility 2027
WBV-10620 30 Facility 2027
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment

Page 775 of 1105 ends

ID Diameter, inch Type CIP Year
A-1. Proposed Valve R&R
WCHV-10035 30 Facility 2027
WMTV-10002 30 Facility 2027
WCHV-10033 24 Facility 2027
WCHV-10037 24 Facility 2027
WCHV-10032 30 Facility 2027
WMOV-10007 30 Facility 2027
WMOV-10008 24 Facility 2027
WCHV-10034 30 Facility 2027
WCHV-10036 24 Facility 2027
WBV-10612 30 Facility 2027
WBV-10613 30 Facility 2027
WBV-10470 30 Facility 2027
WBV-10478 30 Facility 2027
WBV-10614 30 Facility 2027
WBV-10477 30 Facility 2027
WBV-10480 42 Facility 2027
WBV-10679 36 Facility 2027
WBV-10471 30 Facility 2027
WBV-10469 30 Facility 2027
WBV-10472 30 Facility 2027
WMTV-10014 24 Facility 2027
WMTV-10009 48 Facility 2027
WMOV-10013 30 Facility 2027
WCV-10019 24 Facility 2027
WMOV-10012 48 Facility 2027
WMTV-10001 30 Facility 2027
WCHV-10031 30 Facility 2027
WBV-10481 30 Transmission 2028
WBV-10338 30 Transmission 2028
WBV-10483 30 Transmission 2028
WBV-10514 30 Transmission 2028
WBV-10513 30 Transmission 2028
WBV-10339 24 Transmission 2028
WBV-10461 30 Transmission 2028
WMOV-10003 24 Transmission 2028
WBV-10482 30 Transmission 2028
WARV-10342 24 Transmission 2028
WBV-10542 24 Transmission 2028
WBV-10363 24 Transmission 2028
WBV-10178 24 Transmission 2028
WCHV-10019 24 Transmission 2028
WCHV-10012 24 Transmission 2028
WMOV-10017 24 Transmission 2028
WBV-10684 30 Transmission 2032
WMOV-10014 30 Transmission 2034
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment

Page 776 of 1105 ends

ID Diameter, inch Type CIP Year
A-1. Proposed Valve R&R
WCHV-10018 30 Transmission 2034
WCHV-10056 30 Transmission 2034
WCHV-10057 30 Transmission 2034
WMOV-10015 30 Transmission 2034
WBV-10629 36 Transmission 2035
WBV-10631 36 Transmission 2035
WBV-10630 36 Transmission 2035
WBL-10953 42 Transmission 2035
WSV-10001 36 Transmission 2035
WARV-10410 42 Transmission 2035
WBV-10623 36 Transmission 2035
WBV-10476 36 Transmission 2035
WBL-10954 42 Transmission 2035
WSV-10002 36 Transmission 2035
WSV-10000 36 Transmission 2035
WBL-10955 42 Transmission 2035
WBV-10624 36 Transmission 2035
WBV-10475 36 Transmission 2035
WMOV-10026 42 Transmission 2035
WBV-10637 36 Transmission Long-Term (2036-2050)
WBV-10638 36 Transmission Long-Term (2036-2050)
WBV-10636 36 Transmission Long-Term (2036-2050)
WMOV-10023 36 Transmission Long-Term (2036-2050)
WBV-10553 36 Transmission Long-Term (2036-2050)
WBV-10552 36 Transmission Long-Term (2036-2050)
WBV-10541 36 Transmission Long-Term (2036-2050)
WBV-10579 36 Transmission Long-Term (2036-2050)
WBV-10551 36 Transmission Long-Term (2036-2050)
WBV-10438 30 Transmission Long-Term (2036-2050)
WBV-10555 36 Transmission Long-Term (2036-2050)
WBV-10359 24 Transmission Long-Term (2036-2050)
WBV-10358 24 Transmission Long-Term (2036-2050)
WBV-10434 24 Transmission Long-Term (2036-2050)
WMOV-10002 24 Transmission Long-Term (2036-2050)
WMOV-10004 30 Transmission Long-Term (2036-2050)
WBV-10430 30 Transmission Long-Term (2036-2050)
WBV-10420 30 Transmission Long-Term (2036-2050)
WBV-10421 30 Transmission Long-Term (2036-2050)
WBV-10511 36 Transmission Long-Term (2036-2050)
WBV-10509 36 Transmission Long-Term (2036-2050)
WBV-10510 36 Transmission Long-Term (2036-2050)
WBV-10403 42 Transmission Long-Term (2036-2050)
WBV-10640 42 Transmission Long-Term (2036-2050)
WBV-10648 42 Transmission Long-Term (2036-2050)
WBV-10396 42 Transmission Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment

Page 777 of 1105 ends

ID Diameter, inch Type CIP Year
A-1. Proposed Valve R&R
WBV-10400 42 Transmission Long-Term (2036-2050)
WBV-10635 36 Transmission Long-Term (2036-2050)
WMOV-10024 36 Transmission Long-Term (2036-2050)
WMTV-10004 36 Transmission Long-Term (2036-2050)
WBV-10593 30 Transmission Long-Term (2036-2050)
WBV-10590 30 Transmission Long-Term (2036-2050)
WBV-10457 24 Transmission Long-Term (2036-2050)
WARV-10393 24 Transmission Long-Term (2036-2050)
WCHV-10011 24 Transmission Long-Term (2036-2050)
WARV-10271 30 Transmission Long-Term (2036-2050)
WBV-10429 30 Transmission Long-Term (2036-2050)
WBV-10419 30 Transmission Long-Term (2036-2050)
WBV-10428 30 Transmission Long-Term (2036-2050)
WBV-10683 30 Transmission Long-Term (2036-2050)
WBV-10399 42 Transmission Long-Term (2036-2050)
WGV-10744 42 Transmission Long-Term (2036-2050)
WARV-10258 42 Transmission Long-Term (2036-2050)
WBV-10397 42 Transmission Long-Term (2036-2050)
WBV-10445 42 Transmission Long-Term (2036-2050)
WARV-10412 36 Transmission Long-Term (2036-2050)
WARV-10411 36 Transmission Long-Term (2036-2050)
WBV-10446 42 Transmission Long-Term (2036-2050)
WBV-10387 36 Transmission Long-Term (2036-2050)
WMOV-10020 36 Transmission Long-Term (2036-2050)
WMTV-10006 42 Transmission Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment

Page 778 of 1105 ends

Proposed Pipeline and Service Lateral R&R
Appendix A-2

Page 779 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Lateral No ID (Count = 208) Varies - 2025
Lateral No ID (Count = 769) Varies - 2026
Lateral No ID (Count = 562) Varies - 2027
Lateral No ID (Count = 562) Varies - 2028
Lateral No ID (Count = 718) Varies - 2029
Lateral No ID (Count = 719) Varies - 2030
Pipeline W-12525 8 91 Long-Term (2036-2050)
Pipeline W-12526 8 278 Long-Term (2036-2050)
Pipeline W-12527 8 355 Long-Term (2036-2050)
Pipeline W-12528 8 101 Long-Term (2036-2050)
Pipeline W-12643 8 54 Long-Term (2036-2050)
Pipeline W-12644 8 397 Long-Term (2036-2050)
Pipeline W-12647 8 196 Long-Term (2036-2050)
Pipeline W-12648 8 50 Long-Term (2036-2050)
Pipeline W-12672 8 537 Long-Term (2036-2050)
Pipeline W-13532 8 271 Long-Term (2036-2050)
Pipeline W-13534 8 611 Long-Term (2036-2050)
Pipeline W-13535 8 35 Long-Term (2036-2050)
Pipeline W-13729 8 317 Long-Term (2036-2050)
Pipeline W-14123 8 271 Long-Term (2036-2050)
Pipeline W-14124 8 50 Long-Term (2036-2050)
Pipeline W-10332 8 29 Long-Term (2036-2050)
Pipeline W-10333 8 701 Long-Term (2036-2050)
Pipeline W-10617 8 218 Long-Term (2036-2050)
Pipeline W-10618 8 37 Long-Term (2036-2050)
Pipeline W-10917 8 294 Long-Term (2036-2050)
Pipeline W-10918 8 69 Long-Term (2036-2050)
Pipeline W-10919 8 40 Long-Term (2036-2050)
Pipeline W-11797 8 34 Long-Term (2036-2050)
Pipeline W-11798 8 596 Long-Term (2036-2050)
Pipeline W-11799 8 555 Long-Term (2036-2050)
Pipeline W-11800 8 111 Long-Term (2036-2050)
Pipeline W-11804 8 38 Long-Term (2036-2050)
Pipeline W-11805 8 594 Long-Term (2036-2050)
Pipeline W-11806 8 587 Long-Term (2036-2050)
Pipeline W-11875 8 332 Long-Term (2036-2050)
Pipeline W-11876 8 505 Long-Term (2036-2050)
Pipeline W-11877 8 420 Long-Term (2036-2050)
Pipeline W-11878 8 61 Long-Term (2036-2050)
Pipeline W-11879 8 235 Long-Term (2036-2050)
Pipeline W-11880 8 558 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 780 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-11885 8 672 Long-Term (2036-2050)
Pipeline W-11886 8 41 Long-Term (2036-2050)
Pipeline W-11887 8 172 Long-Term (2036-2050)
Pipeline W-11888 8 556 Long-Term (2036-2050)
Pipeline W-11900 8 207 Long-Term (2036-2050)
Pipeline W-11901 8 38 Long-Term (2036-2050)
Pipeline W-11925 8 272 Long-Term (2036-2050)
Pipeline W-11926 8 43 Long-Term (2036-2050)
Pipeline W-11928 8 66 Long-Term (2036-2050)
Pipeline W-11929 8 52 Long-Term (2036-2050)
Pipeline W-11937 8 412 Long-Term (2036-2050)
Pipeline W-12108 8 32 Long-Term (2036-2050)
Pipeline W-12109 8 325 Long-Term (2036-2050)
Pipeline W-12110 8 351 Long-Term (2036-2050)
Pipeline W-12111 8 28 Long-Term (2036-2050)
Pipeline W-12125 8 383 Long-Term (2036-2050)
Pipeline W-12551 8 50 Long-Term (2036-2050)
Pipeline W-13015 8 280 Long-Term (2036-2050)
Pipeline W-13193 8 236 Long-Term (2036-2050)
Pipeline W-13254 8 40 Long-Term (2036-2050)
Pipeline W-13255 8 535 Long-Term (2036-2050)
Pipeline W-13256 8 41 Long-Term (2036-2050)
Pipeline W-13290 8 415 Long-Term (2036-2050)
Pipeline W-13325 8 200 Long-Term (2036-2050)
Pipeline W-13328 8 36 Long-Term (2036-2050)
Pipeline W-13329 8 786 Long-Term (2036-2050)
Pipeline W-13330 8 222 Long-Term (2036-2050)
Pipeline W-13331 8 249 Long-Term (2036-2050)
Pipeline W-13799 8 37 Long-Term (2036-2050)
Pipeline W-13800 8 578 Long-Term (2036-2050)
Pipeline W-13801 8 38 Long-Term (2036-2050)
Pipeline W-16569 8 268 Long-Term (2036-2050)
Pipeline W-16570 8 612 Long-Term (2036-2050)
Pipeline W-16571 8 404 Long-Term (2036-2050)
Pipeline W-16573 8 35 Long-Term (2036-2050)
Pipeline W-16574 8 659 Long-Term (2036-2050)
Pipeline W-16575 8 39 Long-Term (2036-2050)
Pipeline W-10330 8 60 Long-Term (2036-2050)
Pipeline W-10331 8 448 Long-Term (2036-2050)
Pipeline W-12309 8 54 Long-Term (2036-2050)
Pipeline W-12310 8 490 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 781 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-12458 8 487 Long-Term (2036-2050)
Pipeline W-12459 8 59 Long-Term (2036-2050)
Pipeline W-12555 8 64 Long-Term (2036-2050)
Pipeline W-12556 8 620 Long-Term (2036-2050)
Pipeline W-13137 8 218 Long-Term (2036-2050)
Pipeline W-13145 8 60 Long-Term (2036-2050)
Pipeline W-13146 8 650 Long-Term (2036-2050)
Pipeline W-13182 8 196 Long-Term (2036-2050)
Pipeline W-13183 8 55 Long-Term (2036-2050)
Pipeline W-13205 8 276 Long-Term (2036-2050)
Pipeline W-13206 8 54 Long-Term (2036-2050)
Pipeline W-13240 8 580 Long-Term (2036-2050)
Pipeline W-13241 8 503 Long-Term (2036-2050)
Pipeline W-13242 8 362 Long-Term (2036-2050)
Pipeline W-10290 8 225 Long-Term (2036-2050)
Pipeline W-12496 8 181 Long-Term (2036-2050)
Pipeline W-12497 8 62 Long-Term (2036-2050)
Pipeline W-10742 8 127 Long-Term (2036-2050)
Pipeline W-10743 8 459 Long-Term (2036-2050)
Pipeline W-10744 8 231 Long-Term (2036-2050)
Pipeline W-10745 8 270 Long-Term (2036-2050)
Pipeline W-10746 8 121 Long-Term (2036-2050)
Pipeline W-12428 8 37 Long-Term (2036-2050)
Pipeline W-12429 8 418 Long-Term (2036-2050)
Pipeline W-12430 8 410 Long-Term (2036-2050)
Pipeline W-12431 8 27 Long-Term (2036-2050)
Pipeline W-12517 8 444 Long-Term (2036-2050)
Pipeline W-12518 8 54 Long-Term (2036-2050)
Pipeline W-15177 8 613 Long-Term (2036-2050)
Pipeline W-15178 8 361 Long-Term (2036-2050)
Pipeline W-17609 8 18 Long-Term (2036-2050)
Pipeline W-12199 8 356 Long-Term (2036-2050)
Pipeline W-12200 8 376 Long-Term (2036-2050)
Pipeline W-12201 8 192 Long-Term (2036-2050)
Pipeline W-12256 8 198 Long-Term (2036-2050)
Pipeline W-12257 8 66 Long-Term (2036-2050)
Pipeline W-10283 8 437 Long-Term (2036-2050)
Pipeline W-10284 8 405 Long-Term (2036-2050)
Pipeline W-10285 8 34 Long-Term (2036-2050)
Pipeline W-10649 8 43 Long-Term (2036-2050)
Pipeline W-10650 8 361 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 782 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-10728 8 1,182 Long-Term (2036-2050)
Pipeline W-10729 8 318 Long-Term (2036-2050)
Pipeline W-10733 8 67 Long-Term (2036-2050)
Pipeline W-10734 8 464 Long-Term (2036-2050)
Pipeline W-10735 8 74 Long-Term (2036-2050)
Pipeline W-10740 8 191 Long-Term (2036-2050)
Pipeline W-10741 8 44 Long-Term (2036-2050)
Pipeline W-11173 8 189 Long-Term (2036-2050)
Pipeline W-11174 8 138 Long-Term (2036-2050)
Pipeline W-11175 8 57 Long-Term (2036-2050)
Pipeline W-11176 8 32 Long-Term (2036-2050)
Pipeline W-11185 8 22 Long-Term (2036-2050)
Pipeline W-11192 8 605 Long-Term (2036-2050)
Pipeline W-11193 8 315 Long-Term (2036-2050)
Pipeline W-11194 8 74 Long-Term (2036-2050)
Pipeline W-11201 8 41 Long-Term (2036-2050)
Pipeline W-11202 8 197 Long-Term (2036-2050)
Pipeline W-11902 8 48 Long-Term (2036-2050)
Pipeline W-11903 8 294 Long-Term (2036-2050)
Pipeline W-11904 8 24 Long-Term (2036-2050)
Pipeline W-11946 8 416 Long-Term (2036-2050)
Pipeline W-11981 8 59 Long-Term (2036-2050)
Pipeline W-11982 8 328 Long-Term (2036-2050)
Pipeline W-12113 8 1 Long-Term (2036-2050)
Pipeline W-12120 8 199 Long-Term (2036-2050)
Pipeline W-12121 8 189 Long-Term (2036-2050)
Pipeline W-12130 8 389 Long-Term (2036-2050)
Pipeline W-12131 8 379 Long-Term (2036-2050)
Pipeline W-12132 8 41 Long-Term (2036-2050)
Pipeline W-12133 8 387 Long-Term (2036-2050)
Pipeline W-12134 8 45 Long-Term (2036-2050)
Pipeline W-12135 8 384 Long-Term (2036-2050)
Pipeline W-12163 8 25 Long-Term (2036-2050)
Pipeline W-12164 8 295 Long-Term (2036-2050)
Pipeline W-12165 8 39 Long-Term (2036-2050)
Pipeline W-12166 8 383 Long-Term (2036-2050)
Pipeline W-12167 8 26 Long-Term (2036-2050)
Pipeline W-12168 8 214 Long-Term (2036-2050)
Pipeline W-12169 8 218 Long-Term (2036-2050)
Pipeline W-12170 8 404 Long-Term (2036-2050)
Pipeline W-12171 8 44 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 783 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-12172 8 286 Long-Term (2036-2050)
Pipeline W-12173 8 71 Long-Term (2036-2050)
Pipeline W-12174 8 355 Long-Term (2036-2050)
Pipeline W-12175 8 53 Long-Term (2036-2050)
Pipeline W-12176 8 344 Long-Term (2036-2050)
Pipeline W-12177 8 12 Long-Term (2036-2050)
Pipeline W-12178 8 26 Long-Term (2036-2050)
Pipeline W-12181 8 220 Long-Term (2036-2050)
Pipeline W-12182 8 167 Long-Term (2036-2050)
Pipeline W-12183 8 366 Long-Term (2036-2050)
Pipeline W-12185 8 16 Long-Term (2036-2050)
Pipeline W-12186 8 333 Long-Term (2036-2050)
Pipeline W-12187 8 24 Long-Term (2036-2050)
Pipeline W-12188 8 21 Long-Term (2036-2050)
Pipeline W-12189 8 30 Long-Term (2036-2050)
Pipeline W-12190 8 353 Long-Term (2036-2050)
Pipeline W-12191 8 207 Long-Term (2036-2050)
Pipeline W-12192 8 219 Long-Term (2036-2050)
Pipeline W-12193 8 46 Long-Term (2036-2050)
Pipeline W-12194 8 270 Long-Term (2036-2050)
Pipeline W-12195 8 71 Long-Term (2036-2050)
Pipeline W-12208 8 179 Long-Term (2036-2050)
Pipeline W-12209 8 225 Long-Term (2036-2050)
Pipeline W-12211 8 362 Long-Term (2036-2050)
Pipeline W-12215 8 62 Long-Term (2036-2050)
Pipeline W-12216 8 287 Long-Term (2036-2050)
Pipeline W-12217 8 54 Long-Term (2036-2050)
Pipeline W-12218 8 399 Long-Term (2036-2050)
Pipeline W-12219 8 392 Long-Term (2036-2050)
Pipeline W-12224 8 70 Long-Term (2036-2050)
Pipeline W-12226 8 381 Long-Term (2036-2050)
Pipeline W-12227 8 55 Long-Term (2036-2050)
Pipeline W-12228 8 348 Long-Term (2036-2050)
Pipeline W-12229 8 381 Long-Term (2036-2050)
Pipeline W-12234 8 408 Long-Term (2036-2050)
Pipeline W-12235 8 379 Long-Term (2036-2050)
Pipeline W-12236 8 331 Long-Term (2036-2050)
Pipeline W-12237 8 53 Long-Term (2036-2050)
Pipeline W-12293 8 42 Long-Term (2036-2050)
Pipeline W-12294 8 299 Long-Term (2036-2050)
Pipeline W-12295 8 528 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 784 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-12296 8 60 Long-Term (2036-2050)
Pipeline W-12297 8 196 Long-Term (2036-2050)
Pipeline W-12298 8 245 Long-Term (2036-2050)
Pipeline W-12299 8 223 Long-Term (2036-2050)
Pipeline W-12300 8 32 Long-Term (2036-2050)
Pipeline W-12301 8 244 Long-Term (2036-2050)
Pipeline W-12319 8 258 Long-Term (2036-2050)
Pipeline W-12324 8 334 Long-Term (2036-2050)
Pipeline W-12325 8 188 Long-Term (2036-2050)
Pipeline W-12326 8 137 Long-Term (2036-2050)
Pipeline W-12327 8 283 Long-Term (2036-2050)
Pipeline W-12328 8 413 Long-Term (2036-2050)
Pipeline W-12332 8 219 Long-Term (2036-2050)
Pipeline W-12333 8 38 Long-Term (2036-2050)
Pipeline W-12393 8 215 Long-Term (2036-2050)
Pipeline W-12394 8 363 Long-Term (2036-2050)
Pipeline W-12395 8 352 Long-Term (2036-2050)
Pipeline W-12396 8 399 Long-Term (2036-2050)
Pipeline W-12513 8 284 Long-Term (2036-2050)
Pipeline W-12516 8 7 Long-Term (2036-2050)
Pipeline W-12984 8 351 Long-Term (2036-2050)
Pipeline W-15983 8 456 Long-Term (2036-2050)
Pipeline W-16190 8 25 Long-Term (2036-2050)
Pipeline W-16191 8 151 Long-Term (2036-2050)
Pipeline W-16192 8 175 Long-Term (2036-2050)
Pipeline W-16193 8 39 Long-Term (2036-2050)
Pipeline W-16194 8 185 Long-Term (2036-2050)
Pipeline W-16195 8 192 Long-Term (2036-2050)
Pipeline W-16375 8 69 Long-Term (2036-2050)
Pipeline W-16567 8 148 Long-Term (2036-2050)
Pipeline W-16579 8 189 Long-Term (2036-2050)
Pipeline W-16794 8 312 Long-Term (2036-2050)
Pipeline W-12225 8 149 Long-Term (2036-2050)
Pipeline W-12243 8 2 Long-Term (2036-2050)
Pipeline W-18046 8 186 Long-Term (2036-2050)
Pipeline W-10281 8 284 Long-Term (2036-2050)
Pipeline W-10747 8 32 Long-Term (2036-2050)
Pipeline W-10748 8 285 Long-Term (2036-2050)
Pipeline W-11197 8 52 Long-Term (2036-2050)
Pipeline W-11198 8 202 Long-Term (2036-2050)
Pipeline W-11199 8 53 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 785 of 1105 ends