A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-11200 8 198 Long-Term (2036-2050)
Pipeline W-11996 8 792 Long-Term (2036-2050)
Pipeline W-12019 8 35 Long-Term (2036-2050)
Pipeline W-12020 8 221 Long-Term (2036-2050)
Pipeline W-12021 8 334 Long-Term (2036-2050)
Pipeline W-12022 8 277 Long-Term (2036-2050)
Pipeline W-12023 8 237 Long-Term (2036-2050)
Pipeline W-12024 8 35 Long-Term (2036-2050)
Pipeline W-12463 8 367 Long-Term (2036-2050)
Pipeline W-12464 8 76 Long-Term (2036-2050)
Pipeline W-12519 8 40 Long-Term (2036-2050)
Pipeline W-12520 8 213 Long-Term (2036-2050)
Pipeline W-12521 8 46 Long-Term (2036-2050)
Pipeline W-12522 8 226 Long-Term (2036-2050)
Pipeline W-12450 8 452 Long-Term (2036-2050)
Pipeline W-12451 8 70 Long-Term (2036-2050)
Pipeline W-12977 8 40 Long-Term (2036-2050)
Pipeline W-12978 8 286 Long-Term (2036-2050)
Pipeline W-12979 8 157 Long-Term (2036-2050)
Pipeline W-12980 8 41 Long-Term (2036-2050)
Pipeline W-12981 8 209 Long-Term (2036-2050)
Pipeline W-12831 10 56 Long-Term (2036-2050)
Pipeline W-12832 10 245 Long-Term (2036-2050)
Pipeline W-13034 10 53 Long-Term (2036-2050)
Pipeline W-13035 10 82 Long-Term (2036-2050)
Pipeline W-13047 10 53 Long-Term (2036-2050)
Pipeline W-13048 10 178 Long-Term (2036-2050)
Pipeline W-13083 10 55 Long-Term (2036-2050)
Pipeline W-13084 10 298 Long-Term (2036-2050)
Pipeline W-13411 10 263 Long-Term (2036-2050)
Pipeline W-13412 10 198 Long-Term (2036-2050)
Pipeline W-13413 10 195 Long-Term (2036-2050)
Pipeline W-13414 10 472 Long-Term (2036-2050)
Pipeline W-13727 10 57 Long-Term (2036-2050)
Pipeline W-13728 10 498 Long-Term (2036-2050)
Pipeline W-13825 10 311 Long-Term (2036-2050)
Pipeline W-13894 10 34 Long-Term (2036-2050)
Pipeline W-11392 10 67 Long-Term (2036-2050)
Pipeline W-11393 10 248 Long-Term (2036-2050)
Pipeline W-11394 10 36 Long-Term (2036-2050)
Pipeline W-11439 10 302 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 786 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-11440 10 452 Long-Term (2036-2050)
Pipeline W-11441 10 70 Long-Term (2036-2050)
Pipeline W-11807 10 269 Long-Term (2036-2050)
Pipeline W-12541 10 246 Long-Term (2036-2050)
Pipeline W-13014 10 238 Long-Term (2036-2050)
Pipeline W-13039 10 217 Long-Term (2036-2050)
Pipeline W-13040 10 45 Long-Term (2036-2050)
Pipeline W-13257 10 251 Long-Term (2036-2050)
Pipeline W-13258 10 208 Long-Term (2036-2050)
Pipeline W-13297 10 277 Long-Term (2036-2050)
Pipeline W-13355 10 434 Long-Term (2036-2050)
Pipeline W-13356 10 359 Long-Term (2036-2050)
Pipeline W-13396 10 407 Long-Term (2036-2050)
Pipeline W-13397 10 36 Long-Term (2036-2050)
Pipeline W-13398 10 250 Long-Term (2036-2050)
Pipeline W-13399 10 40 Long-Term (2036-2050)
Pipeline W-13400 10 255 Long-Term (2036-2050)
Pipeline W-13401 10 41 Long-Term (2036-2050)
Pipeline W-13405 10 406 Long-Term (2036-2050)
Pipeline W-13406 10 54 Long-Term (2036-2050)
Pipeline W-13410 10 22 Long-Term (2036-2050)
Pipeline W-17130 10 19 Long-Term (2036-2050)
Pipeline W-17608 10 24 Long-Term (2036-2050)
Pipeline W-13135 10 201 Long-Term (2036-2050)
Pipeline W-13136 10 357 Long-Term (2036-2050)
Pipeline W-10287 10 227 Long-Term (2036-2050)
Pipeline W-12027 10 184 Long-Term (2036-2050)
Pipeline W-12028 10 58 Long-Term (2036-2050)
Pipeline W-12408 10 67 Long-Term (2036-2050)
Pipeline W-12409 10 180 Long-Term (2036-2050)
Pipeline W-12492 10 187 Long-Term (2036-2050)
Pipeline W-12493 10 53 Long-Term (2036-2050)
Pipeline W-12246 10 256 Long-Term (2036-2050)
Pipeline W-10736 10 337 Long-Term (2036-2050)
Pipeline W-10737 10 288 Long-Term (2036-2050)
Pipeline W-10738 10 316 Long-Term (2036-2050)
Pipeline W-10739 10 85 Long-Term (2036-2050)
Pipeline W-11186 10 43 Long-Term (2036-2050)
Pipeline W-12180 10 62 Long-Term (2036-2050)
Pipeline W-12356 10 65 Long-Term (2036-2050)
Pipeline W-12375 10 31 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 787 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-12376 10 193 Long-Term (2036-2050)
Pipeline W-12402 10 214 Long-Term (2036-2050)
Pipeline W-12403 10 50 Long-Term (2036-2050)
Pipeline W-12179 10 188 Long-Term (2036-2050)
Pipeline W-18044 10 154 Long-Term (2036-2050)
Pipeline W-10297 10 135 Long-Term (2036-2050)
Pipeline W-11187 10 152 Long-Term (2036-2050)
Pipeline W-11188 10 56 Long-Term (2036-2050)
Pipeline W-11195 10 195 Long-Term (2036-2050)
Pipeline W-11196 10 58 Long-Term (2036-2050)
Pipeline W-11997 10 478 Long-Term (2036-2050)
Pipeline W-12342 10 65 Long-Term (2036-2050)
Pipeline W-12343 10 612 Long-Term (2036-2050)
Pipeline W-12344 10 36 Long-Term (2036-2050)
Pipeline W-12357 10 264 Long-Term (2036-2050)
Pipeline W-12358 10 41 Long-Term (2036-2050)
Pipeline W-12359 10 203 Long-Term (2036-2050)
Pipeline W-12442 10 230 Long-Term (2036-2050)
Pipeline W-12443 10 86 Long-Term (2036-2050)
Pipeline W-12444 10 383 Long-Term (2036-2050)
Pipeline W-12445 10 206 Long-Term (2036-2050)
Pipeline W-12446 10 38 Long-Term (2036-2050)
Pipeline W-12465 10 313 Long-Term (2036-2050)
Pipeline W-12466 10 53 Long-Term (2036-2050)
Pipeline W-12489 10 196 Long-Term (2036-2050)
Pipeline W-12490 10 33 Long-Term (2036-2050)
Pipeline W-12515 10 363 Long-Term (2036-2050)
Pipeline W-17603 10 100 Long-Term (2036-2050)
Pipeline W-10298 12 448 Long-Term (2036-2050)
Pipeline W-10299 12 292 Long-Term (2036-2050)
Pipeline W-10300 12 103 Long-Term (2036-2050)
Pipeline W-10301 12 99 Long-Term (2036-2050)
Pipeline W-10302 12 226 Long-Term (2036-2050)
Pipeline W-11217 12 181 Long-Term (2036-2050)
Pipeline W-11222 12 349 Long-Term (2036-2050)
Pipeline W-11226 12 29 Long-Term (2036-2050)
Pipeline W-11227 12 270 Long-Term (2036-2050)
Pipeline W-11228 12 60 Long-Term (2036-2050)
Pipeline W-11232 12 362 Long-Term (2036-2050)
Pipeline W-11238 12 364 Long-Term (2036-2050)
Pipeline W-11240 12 76 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 788 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-11241 12 252 Long-Term (2036-2050)
Pipeline W-11739 12 285 Long-Term (2036-2050)
Pipeline W-11740 12 426 Long-Term (2036-2050)
Pipeline W-12524 12 253 Long-Term (2036-2050)
Pipeline W-12532 12 242 Long-Term (2036-2050)
Pipeline W-12536 12 134 Long-Term (2036-2050)
Pipeline W-12537 12 121 Long-Term (2036-2050)
Pipeline W-12538 12 201 Long-Term (2036-2050)
Pipeline W-12539 12 38 Long-Term (2036-2050)
Pipeline W-12540 12 238 Long-Term (2036-2050)
Pipeline W-12809 12 296 Long-Term (2036-2050)
Pipeline W-12810 12 51 Long-Term (2036-2050)
Pipeline W-13850 12 304 Long-Term (2036-2050)
Pipeline W-13851 12 411 Long-Term (2036-2050)
Pipeline W-17562 12 210 Long-Term (2036-2050)
Pipeline W-17563 12 68 Long-Term (2036-2050)
Pipeline W-17564 12 25 Long-Term (2036-2050)
Pipeline W-12987 12 482 Long-Term (2036-2050)
Pipeline W-11086 12 330 Long-Term (2036-2050)
Pipeline W-12821 12 319 Long-Term (2036-2050)
Pipeline W-12822 12 359 Long-Term (2036-2050)
Pipeline W-11216 12 278 Long-Term (2036-2050)
Pipeline W-12759 12 66 Long-Term (2036-2050)
Pipeline W-12760 12 379 Long-Term (2036-2050)
Pipeline W-10901 12 465 Long-Term (2036-2050)
Pipeline W-10902 12 38 Long-Term (2036-2050)
Pipeline W-11960 12 323 Long-Term (2036-2050)
Pipeline W-12406 12 327 Long-Term (2036-2050)
Pipeline W-12755 12 244 Long-Term (2036-2050)
Pipeline W-12756 12 56 Long-Term (2036-2050)
Pipeline W-12757 12 16 Long-Term (2036-2050)
Pipeline W-12758 12 175 Long-Term (2036-2050)
Pipeline W-11990 12 210 Long-Term (2036-2050)
Pipeline W-11991 12 52 Long-Term (2036-2050)
Pipeline W-10543 12 56 Long-Term (2036-2050)
Pipeline W-10544 12 269 Long-Term (2036-2050)
Pipeline W-10545 12 43 Long-Term (2036-2050)
Pipeline W-10549 12 58 Long-Term (2036-2050)
Pipeline W-10550 12 361 Long-Term (2036-2050)
Pipeline W-10551 12 51 Long-Term (2036-2050)
Pipeline W-10631 12 44 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 789 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-10632 12 359 Long-Term (2036-2050)
Pipeline W-10635 12 360 Long-Term (2036-2050)
Pipeline W-10639 12 30 Long-Term (2036-2050)
Pipeline W-10640 12 297 Long-Term (2036-2050)
Pipeline W-10641 12 58 Long-Term (2036-2050)
Pipeline W-10647 12 22 Long-Term (2036-2050)
Pipeline W-10648 12 360 Long-Term (2036-2050)
Pipeline W-11223 12 32 Long-Term (2036-2050)
Pipeline W-11239 12 351 Long-Term (2036-2050)
Pipeline W-11968 12 442 Long-Term (2036-2050)
Pipeline W-12239 12 406 Long-Term (2036-2050)
Pipeline W-12321 12 72 Long-Term (2036-2050)
Pipeline W-12322 12 289 Long-Term (2036-2050)
Pipeline W-12323 12 344 Long-Term (2036-2050)
Pipeline W-12507 12 242 Long-Term (2036-2050)
Pipeline W-12749 12 240 Long-Term (2036-2050)
Pipeline W-17161 12 98 Long-Term (2036-2050)
Pipeline W-17162 12 280 Long-Term (2036-2050)
Pipeline W-17183 12 81 Long-Term (2036-2050)
Pipeline W-12508 12 69 Long-Term (2036-2050)
Pipeline W-16048 12 255 Long-Term (2036-2050)
Pipeline W-18049 12 167 Long-Term (2036-2050)
Pipeline W-18072 12 614 Long-Term (2036-2050)
Pipeline W-12015 12 80 Long-Term (2036-2050)
Pipeline W-12016 12 463 Long-Term (2036-2050)
Pipeline W-12017 12 320 Long-Term (2036-2050)
Pipeline W-12503 12 51 Long-Term (2036-2050)
Pipeline W-12504 12 219 Long-Term (2036-2050)
Pipeline W-11841 12 379 Long-Term (2036-2050)
Pipeline W-11842 12 310 Long-Term (2036-2050)
Pipeline W-11843 12 8 Long-Term (2036-2050)
Pipeline W-12137 12 722 Long-Term (2036-2050)
Pipeline W-12138 12 858 Long-Term (2036-2050)
Pipeline W-17184 12 269 Long-Term (2036-2050)
Pipeline W-17185 12 10 Long-Term (2036-2050)
Pipeline W-17186 12 18 Long-Term (2036-2050)
Pipeline W-17187 12 244 Long-Term (2036-2050)
Pipeline W-17188 12 95 Long-Term (2036-2050)
Pipeline W-17189 12 324 Long-Term (2036-2050)
Pipeline W-17190 12 268 Long-Term (2036-2050)
Pipeline W-17191 12 439 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 790 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-17192 12 96 Long-Term (2036-2050)
Pipeline W-17193 12 64 Long-Term (2036-2050)
Pipeline W-17194 12 229 Long-Term (2036-2050)
Pipeline W-17195 12 69 Long-Term (2036-2050)
Pipeline W-17196 12 192 Long-Term (2036-2050)
Pipeline W-17197 12 35 Long-Term (2036-2050)
Pipeline W-17198 12 180 Long-Term (2036-2050)
Pipeline W-17199 12 66 Long-Term (2036-2050)
Pipeline W-17200 12 245 Long-Term (2036-2050)
Pipeline W-17201 12 132 Long-Term (2036-2050)
Pipeline W-17202 12 230 Long-Term (2036-2050)
Pipeline W-17203 12 47 Long-Term (2036-2050)
Pipeline W-17204 12 16 Long-Term (2036-2050)
Pipeline W-17205 12 391 Long-Term (2036-2050)
Pipeline W-17206 12 51 Long-Term (2036-2050)
Pipeline W-17207 12 36 Long-Term (2036-2050)
Pipeline W-17577 12 10 Long-Term (2036-2050)
Pipeline W-17578 12 26 Long-Term (2036-2050)
Pipeline W-17579 12 39 Long-Term (2036-2050)
Pipeline W-17580 12 138 Long-Term (2036-2050)
Pipeline W-17584 12 14 Long-Term (2036-2050)
Pipeline W-17585 12 62 Long-Term (2036-2050)
Pipeline W-10453 16 26 Long-Term (2036-2050)
Pipeline W-10454 16 249 Long-Term (2036-2050)
Pipeline W-13895 16 427 Long-Term (2036-2050)
Pipeline W-13896 16 34 Long-Term (2036-2050)
Pipeline W-10636 16 373 Long-Term (2036-2050)
Pipeline W-15997 16 205 Long-Term (2036-2050)
Pipeline W-17568 16 203 Long-Term (2036-2050)
Pipeline W-19118 16 11 Long-Term (2036-2050)
Pipeline W-10620 16 85 Long-Term (2036-2050)
Pipeline W-10637 16 39 Long-Term (2036-2050)
Pipeline W-10638 16 315 Long-Term (2036-2050)
Pipeline W-10642 16 338 Long-Term (2036-2050)
Pipeline W-10643 16 403 Long-Term (2036-2050)
Pipeline W-10645 16 360 Long-Term (2036-2050)
Pipeline W-10646 16 44 Long-Term (2036-2050)
Pipeline W-11733 16 295 Long-Term (2036-2050)
Pipeline W-19115 16 31 Long-Term (2036-2050)
Pipeline W-11757 16 296 Long-Term (2036-2050)
Pipeline W-17567 16 110 Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 791 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Pipeline W-16049 18 389 Long-Term (2036-2050)
Pipeline W-12915 24 479 Long-Term (2036-2050)
Pipeline W-19070 24 11 Long-Term (2036-2050)
Pipeline W-18203 36 132 Long-Term (2036-2050)
Lateral WLAT-10885 - - Long-Term (2036-2050)
Lateral WLAT-10024 - - Long-Term (2036-2050)
Lateral WLAT-11011 - - Long-Term (2036-2050)
Lateral WLAT-11362 - - Long-Term (2036-2050)
Lateral WLAT-10274 - - Long-Term (2036-2050)
Lateral WLAT-11833 - - Long-Term (2036-2050)
Lateral WLAT-10392 - - Long-Term (2036-2050)
Lateral WLAT-10264 - - Long-Term (2036-2050)
Lateral WLAT-10866 - - Long-Term (2036-2050)
Lateral WLAT-11534 - - Long-Term (2036-2050)
Lateral WLAT-12898 - - Long-Term (2036-2050)
Lateral WLAT-10267 - - Long-Term (2036-2050)
Lateral WLAT-11465 - - Long-Term (2036-2050)
Lateral WLAT-11231 - - Long-Term (2036-2050)
Lateral WLAT-10348 - - Long-Term (2036-2050)
Lateral WLAT-13127 - - Long-Term (2036-2050)
Lateral WLAT-12465 - - Long-Term (2036-2050)
Lateral WLAT-13125 - - Long-Term (2036-2050)
Lateral WLAT-10339 - - Long-Term (2036-2050)
Lateral WLAT-10951 - - Long-Term (2036-2050)
Lateral WLAT-10286 - - Long-Term (2036-2050)
Lateral WLAT-10965 - - Long-Term (2036-2050)
Lateral WLAT-10432 - - Long-Term (2036-2050)
Lateral WLAT-10266 - - Long-Term (2036-2050)
Lateral WLAT-11845 - - Long-Term (2036-2050)
Lateral WLAT-11675 - - Long-Term (2036-2050)
Lateral WLAT-10265 - - Long-Term (2036-2050)
Lateral WLAT-10189 - - Long-Term (2036-2050)
Lateral WLAT-11219 - - Long-Term (2036-2050)
Lateral WLAT-12358 - - Long-Term (2036-2050)
Lateral WLAT-12774 - - Long-Term (2036-2050)
Lateral WLAT-10752 - - Long-Term (2036-2050)
Lateral WLAT-12738 - - Long-Term (2036-2050)
Lateral WLAT-11839 - - Long-Term (2036-2050)
Lateral WLAT-13143 - - Long-Term (2036-2050)
Lateral WLAT-11374 - - Long-Term (2036-2050)
Lateral WLAT-11008 - - Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 792 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Lateral WLAT-12212 - - Long-Term (2036-2050)
Lateral WLAT-10836 - - Long-Term (2036-2050)
Lateral WLAT-10191 - - Long-Term (2036-2050)
Lateral WLAT-10821 - - Long-Term (2036-2050)
Lateral WLAT-11028 - - Long-Term (2036-2050)
Lateral WLAT-10419 - - Long-Term (2036-2050)
Lateral WLAT-10270 - - Long-Term (2036-2050)
Lateral WLAT-12773 - - Long-Term (2036-2050)
Lateral WLAT-10472 - - Long-Term (2036-2050)
Lateral WLAT-12091 - - Long-Term (2036-2050)
Lateral WLAT-12769 - - Long-Term (2036-2050)
Lateral WLAT-10832 - - Long-Term (2036-2050)
Lateral WLAT-12973 - - Long-Term (2036-2050)
Lateral WLAT-12794 - - Long-Term (2036-2050)
Lateral WLAT-12056 - - Long-Term (2036-2050)
Lateral WLAT-11841 - - Long-Term (2036-2050)
Lateral WLAT-12797 - - Long-Term (2036-2050)
Lateral WLAT-10749 - - Long-Term (2036-2050)
Lateral WLAT-10285 - - Long-Term (2036-2050)
Lateral WLAT-11373 - - Long-Term (2036-2050)
Lateral WLAT-12233 - - Long-Term (2036-2050)
Lateral WLAT-11956 - - Long-Term (2036-2050)
Lateral WLAT-10268 - - Long-Term (2036-2050)
Lateral WLAT-11009 - - Long-Term (2036-2050)
Lateral WLAT-11355 - - Long-Term (2036-2050)
Lateral WLAT-11686 - - Long-Term (2036-2050)
Lateral WLAT-11040 - - Long-Term (2036-2050)
Lateral WLAT-11239 - - Long-Term (2036-2050)
Lateral WLAT-10340 - - Long-Term (2036-2050)
Lateral WLAT-10878 - - Long-Term (2036-2050)
Lateral WLAT-11847 - - Long-Term (2036-2050)
Lateral WLAT-13261 - - Long-Term (2036-2050)
Lateral WLAT-11171 - - Long-Term (2036-2050)
Lateral WLAT-10379 - - Long-Term (2036-2050)
Lateral WLAT-10341 - - Long-Term (2036-2050)
Lateral WLAT-13245 - - Long-Term (2036-2050)
Lateral WLAT-11569 - - Long-Term (2036-2050)
Lateral WLAT-10819 - - Long-Term (2036-2050)
Lateral WLAT-12791 - - Long-Term (2036-2050)
Lateral WLAT-12009 - - Long-Term (2036-2050)
Lateral WLAT-12796 - - Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 793 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Lateral WLAT-10471 - - Long-Term (2036-2050)
Lateral WLAT-12798 - - Long-Term (2036-2050)
Lateral WLAT-12792 - - Long-Term (2036-2050)
Lateral WLAT-10823 - - Long-Term (2036-2050)
Lateral WLAT-11012 - - Long-Term (2036-2050)
Lateral WLAT-12739 - - Long-Term (2036-2050)
Lateral WLAT-10879 - - Long-Term (2036-2050)
Lateral WLAT-10033 - - Long-Term (2036-2050)
Lateral WLAT-11033 - - Long-Term (2036-2050)
Lateral WLAT-11674 - - Long-Term (2036-2050)
Lateral WLAT-10174 - - Long-Term (2036-2050)
Lateral WLAT-10121 - - Long-Term (2036-2050)
Lateral WLAT-10421 - - Long-Term (2036-2050)
Lateral WLAT-10485 - - Long-Term (2036-2050)
Lateral WLAT-13200 - - Long-Term (2036-2050)
Lateral WLAT-11189 - - Long-Term (2036-2050)
Lateral WLAT-11170 - - Long-Term (2036-2050)
Lateral WLAT-12522 - - Long-Term (2036-2050)
Lateral WLAT-12905 - - Long-Term (2036-2050)
Lateral WLAT-12845 - - Long-Term (2036-2050)
Lateral WLAT-11069 - - Long-Term (2036-2050)
Lateral WLAT-10712 - - Long-Term (2036-2050)
Lateral WLAT-12492 - - Long-Term (2036-2050)
Lateral WLAT-11230 - - Long-Term (2036-2050)
Lateral WLAT-11222 - - Long-Term (2036-2050)
Lateral WLAT-10475 - - Long-Term (2036-2050)
Lateral WLAT-11559 - - Long-Term (2036-2050)
Lateral WLAT-10751 - - Long-Term (2036-2050)
Lateral WLAT-11838 - - Long-Term (2036-2050)
Lateral WLAT-11006 - - Long-Term (2036-2050)
Lateral WLAT-10822 - - Long-Term (2036-2050)
Lateral WLAT-12783 - - Long-Term (2036-2050)
Lateral WLAT-12281 - - Long-Term (2036-2050)
Lateral WLAT-11955 - - Long-Term (2036-2050)
Lateral WLAT-12190 - - Long-Term (2036-2050)
Lateral WLAT-12201 - - Long-Term (2036-2050)
Lateral WLAT-10269 - - Long-Term (2036-2050)
Lateral WLAT-10886 - - Long-Term (2036-2050)
Lateral WLAT-12789 - - Long-Term (2036-2050)
Lateral WLAT-12164 - - Long-Term (2036-2050)
Lateral WLAT-11023 - - Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 794 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Lateral WLAT-11007 - - Long-Term (2036-2050)
Lateral WLAT-12806 - - Long-Term (2036-2050)
Lateral WLAT-11064 - - Long-Term (2036-2050)
Lateral WLAT-11036 - - Long-Term (2036-2050)
Lateral WLAT-11946 - - Long-Term (2036-2050)
Lateral WLAT-10277 - - Long-Term (2036-2050)
Lateral WLAT-13124 - - Long-Term (2036-2050)
Lateral WLAT-11843 - - Long-Term (2036-2050)
Lateral WLAT-11179 - - Long-Term (2036-2050)
Lateral WLAT-10953 - - Long-Term (2036-2050)
Lateral WLAT-12234 - - Long-Term (2036-2050)
Lateral WLAT-13270 - - Long-Term (2036-2050)
Lateral WLAT-11068 - - Long-Term (2036-2050)
Lateral WLAT-13159 - - Long-Term (2036-2050)
Lateral WLAT-12202 - - Long-Term (2036-2050)
Lateral WLAT-13849 - - Long-Term (2036-2050)
Lateral WLAT-11592 - - Long-Term (2036-2050)
Lateral WLAT-10524 - - Long-Term (2036-2050)
Lateral WLAT-10775 - - Long-Term (2036-2050)
Lateral WLAT-10276 - - Long-Term (2036-2050)
Lateral WLAT-10420 - - Long-Term (2036-2050)
Lateral WLAT-10837 - - Long-Term (2036-2050)
Lateral WLAT-10273 - - Long-Term (2036-2050)
Lateral WLAT-10006 - - Long-Term (2036-2050)
Lateral WLAT-10474 - - Long-Term (2036-2050)
Lateral WLAT-12784 - - Long-Term (2036-2050)
Lateral WLAT-11176 - - Long-Term (2036-2050)
Lateral WLAT-13142 - - Long-Term (2036-2050)
Lateral WLAT-11041 - - Long-Term (2036-2050)
Lateral WLAT-10877 - - Long-Term (2036-2050)
Lateral WLAT-11063 - - Long-Term (2036-2050)
Lateral WLAT-10881 - - Long-Term (2036-2050)
Lateral WLAT-10833 - - Long-Term (2036-2050)
Lateral WLAT-13126 - - Long-Term (2036-2050)
Lateral WLAT-12132 - - Long-Term (2036-2050)
Lateral WLAT-10829 - - Long-Term (2036-2050)
Lateral WLAT-13160 - - Long-Term (2036-2050)
Lateral WLAT-10388 - - Long-Term (2036-2050)
Lateral WLAT-13239 - - Long-Term (2036-2050)
Lateral WLAT-11837 - - Long-Term (2036-2050)
Lateral WLAT-13199 - - Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 795 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Lateral WLAT-12020 - - Long-Term (2036-2050)
Lateral WLAT-10750 - - Long-Term (2036-2050)
Lateral WLAT-10718 - - Long-Term (2036-2050)
Lateral WLAT-11846 - - Long-Term (2036-2050)
Lateral WLAT-12501 - - Long-Term (2036-2050)
Lateral WLAT-11735 - - Long-Term (2036-2050)
Lateral WLAT-12394 - - Long-Term (2036-2050)
Lateral WLAT-11072 - - Long-Term (2036-2050)
Lateral WLAT-10418 - - Long-Term (2036-2050)
Lateral WLAT-12203 - - Long-Term (2036-2050)
Lateral WLAT-11363 - - Long-Term (2036-2050)
Lateral WLAT-10526 - - Long-Term (2036-2050)
Lateral WLAT-10186 - - Long-Term (2036-2050)
Lateral WLAT-10282 - - Long-Term (2036-2050)
Lateral WLAT-10776 - - Long-Term (2036-2050)
Lateral WLAT-13248 - - Long-Term (2036-2050)
Lateral WLAT-12320 - - Long-Term (2036-2050)
Lateral WLAT-10820 - - Long-Term (2036-2050)
Lateral WLAT-11010 - - Long-Term (2036-2050)
Lateral WLAT-10281 - - Long-Term (2036-2050)
Lateral WLAT-11065 - - Long-Term (2036-2050)
Lateral WLAT-11570 - - Long-Term (2036-2050)
Lateral WLAT-10478 - - Long-Term (2036-2050)
Lateral WLAT-12531 - - Long-Term (2036-2050)
Lateral WLAT-11948 - - Long-Term (2036-2050)
Lateral WLAT-10828 - - Long-Term (2036-2050)
Lateral WLAT-12004 - - Long-Term (2036-2050)
Lateral WLAT-10759 - - Long-Term (2036-2050)
Lateral WLAT-12232 - - Long-Term (2036-2050)
Lateral WLAT-10272 - - Long-Term (2036-2050)
Lateral WLAT-10279 - - Long-Term (2036-2050)
Lateral WLAT-12790 - - Long-Term (2036-2050)
Lateral WLAT-10651 - - Long-Term (2036-2050)
Lateral WLAT-13262 - - Long-Term (2036-2050)
Lateral WLAT-10882 - - Long-Term (2036-2050)
Lateral WLAT-12611 - - Long-Term (2036-2050)
Lateral WLAT-11464 - - Long-Term (2036-2050)
Lateral WLAT-11840 - - Long-Term (2036-2050)
Lateral WLAT-10192 - - Long-Term (2036-2050)
Lateral WLAT-10477 - - Long-Term (2036-2050)
Lateral WLAT-10875 - - Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 796 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Lateral WLAT-11954 - - Long-Term (2036-2050)
Lateral WLAT-11066 - - Long-Term (2036-2050)
Lateral WLAT-10758 - - Long-Term (2036-2050)
Lateral WLAT-11962 - - Long-Term (2036-2050)
Lateral WLAT-10263 - - Long-Term (2036-2050)
Lateral WLAT-11358 - - Long-Term (2036-2050)
Lateral WLAT-10190 - - Long-Term (2036-2050)
Lateral WLAT-10337 - - Long-Term (2036-2050)
Lateral WLAT-10280 - - Long-Term (2036-2050)
Lateral WLAT-10278 - - Long-Term (2036-2050)
Lateral WLAT-12733 - - Long-Term (2036-2050)
Lateral WLAT-11758 - - Long-Term (2036-2050)
Lateral WLAT-12847 - - Long-Term (2036-2050)
Lateral WLAT-12781 - - Long-Term (2036-2050)
Lateral WLAT-10838 - - Long-Term (2036-2050)
Lateral WLAT-12901 - - Long-Term (2036-2050)
Lateral WLAT-10964 - - Long-Term (2036-2050)
Lateral WLAT-13235 - - Long-Term (2036-2050)
Lateral WLAT-11685 - - Long-Term (2036-2050)
Lateral WLAT-10602 - - Long-Term (2036-2050)
Lateral WLAT-12770 - - Long-Term (2036-2050)
Lateral WLAT-11945 - - Long-Term (2036-2050)
Lateral WLAT-10427 - - Long-Term (2036-2050)
Lateral WLAT-10193 - - Long-Term (2036-2050)
Lateral WLAT-10774 - - Long-Term (2036-2050)
Lateral WLAT-11350 - - Long-Term (2036-2050)
Lateral WLAT-13354 - - Long-Term (2036-2050)
Lateral WLAT-11161 - - Long-Term (2036-2050)
Lateral WLAT-10385 - - Long-Term (2036-2050)
Lateral WLAT-11361 - - Long-Term (2036-2050)
Lateral WLAT-11952 - - Long-Term (2036-2050)
Lateral WLAT-13234 - - Long-Term (2036-2050)
Lateral WLAT-12566 - - Long-Term (2036-2050)
Lateral WLAT-10262 - - Long-Term (2036-2050)
Lateral WLAT-13242 - - Long-Term (2036-2050)
Lateral WLAT-10039 - - Long-Term (2036-2050)
Lateral WLAT-13238 - - Long-Term (2036-2050)
Lateral WLAT-12846 - - Long-Term (2036-2050)
Lateral WLAT-11047 - - Long-Term (2036-2050)
Lateral WLAT-10780 - - Long-Term (2036-2050)
Lateral WLAT-12746 - - Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 797 of 1105 ends

A-2. Proposed Pipeline and Service Lateral R&R
Type ID Diameter, inch Length, ft Replacement Year
Lateral WLAT-11178 - - Long-Term (2036-2050)
Lateral WLAT-13263 - - Long-Term (2036-2050)
Lateral WLAT-11953 - - Long-Term (2036-2050)
Lateral WLAT-12740 - - Long-Term (2036-2050)
Lateral WLAT-10347 - - Long-Term (2036-2050)
Lateral WLAT-12630 - - Long-Term (2036-2050)
Lateral WLAT-12505 - - Long-Term (2036-2050)
Lateral WLAT-10871 - - Long-Term (2036-2050)
Lateral WLAT-12504 - - Long-Term (2036-2050)
Lateral WLAT-12324 - - Long-Term (2036-2050)
Lateral WLAT-11173 - - Long-Term (2036-2050)
Lateral WLAT-12772 - - Long-Term (2036-2050)
Lateral WLAT-10271 - - Long-Term (2036-2050)
Lateral WLAT-10034 - - Long-Term (2036-2050)
Lateral WLAT-10470 - - Long-Term (2036-2050)
268-60-22-20
City of Fairfield
Water Distribution System Condition Assessment
Last Revised: 03-20-2024

Page 798 of 1105 ends

2023 Pump Station Asset Management Plan Update
Appendix G

Page 799 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update

PREPARED FOR
City of Fairfield
ADDENDUM | NOVEMBER 2023

Page 800 of 1105 ends

Potable Water Pump Station
Asset Management Plan – Update
Prepared for
City of Fairfield
Project No. 268-40-22-15
November 29, 2023
Anne Girtz, PE Date
April 14, 2023
Kambria Tiano, PE Date
November 29, 2023
Tyler Newman, PE Date
November 29, 2023
QA/QC Review: Michael Zacharia, PE Date

Page 801 of 1105 ends

N-268-40-22-15-WP-R – AMP Addendum
i City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table of Contents

1.0 Introduction..............................................................................................................................1-1

1.1 Background....................................................................................................................................1-1

1.2 Scope of Update ............................................................................................................................1-1

1.3 Structure of Addendum.................................................................................................................1-2

2.0 Condition Assessment ...............................................................................................................2-1

2.1 Methodology .................................................................................................................................2-1

2.1.1 Visual Condition Assessment...............................................................................................2-1

2.1.2 Pump Performance Testing .................................................................................................2-1

2.1.3 Materials Testing .................................................................................................................2-2

2.2 Analysis and Results ......................................................................................................................2-2

2.2.1 Visual Condition Assessment...............................................................................................2-2

2.2.2 Pump Performance Testing .................................................................................................2-3

2.2.2.1 Pump Capacity............................................................................................................2-3

2.2.2.2 Pump Efficiency ..........................................................................................................2-6

2.2.3 Preliminary Operational Analysis.........................................................................................2-8

2.2.3.1 Preliminary Operational Analysis – Pump Curves......................................................2-8

2.2.3.2 Secondary Operational Analysis – System Curves ...................................................2-11

2.2.4 Materials Testing ...............................................................................................................2-17

2.2.4.1 Rancho Solano Golf Course Pump Station ...............................................................2-17

2.2.4.2 Rancho Solano Raw Water Pump Station ................................................................2-17

3.0 Capacity Assessment .................................................................................................................3-1

3.1 Assessment Approach ...................................................................................................................3-1

3.1.1 Pumping Capacity Requirements.........................................................................................3-1

3.1.2 Water Demands by Pressure Zone ......................................................................................3-3

3.2 Results ...........................................................................................................................................3-3

4.0 Risk Assessment........................................................................................................................4-1

4.1 Methodology .................................................................................................................................4-1

4.2 Results ...........................................................................................................................................4-3

4.2.1 Component Risk Levels........................................................................................................4-3

4.2.2 Component Risk Levels by Pump Station.............................................................................4-3

4.2.3 Facility Risk Levels................................................................................................................4-4

4.2.3.1 Facility Likelihood.......................................................................................................4-4

4.2.3.2 Facility Consequence..................................................................................................4-5

4.2.3.3 Facility Risk Results.....................................................................................................4-6

5.0 Updated Asset Management Plan Recommendations.................................................................5-1

5.1 Recommended 10-Year Rehabilitation/Replacement Program....................................................5-2

5.2 Recommended Next Steps............................................................................................................5-6

Page 802 of 1105 ends

N-268-40-22-15-WP-R – AMP Addendum
ii City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table of Contents

LIST OF TABLES
Table 1-1. Pump Station Facilities included in AMP Update ...............................................................1-2 Table 2-1. Visual Condition and Performance Scoring Index ..............................................................2-1 Table 2-2. Pump Operation versus Nameplate Ratings ......................................................................2-4 Table 2-3. City of Fairfield Pump Station Wire to Water Efficiency ....................................................2-6 Table 2-4. Preliminary Pump Deficiency Observations.....................................................................2-10 Table 2-5. Pump and System Observations.......................................................................................2-12 Table 2-6 General Pump Operating Scenarios ..................................................................................2-13 Table 2-7. Pump and System Conclusions and Recommendations...................................................2-13 Table 2-8. System Valves Immediately Downstream of Pump Station .............................................2-16 Table 3-1. Existing Pumping Capacities by Pressure Zone and Service Area ......................................3-4 Table 4-1. Summary of Component Risk Assessment Results ............................................................4-3 Table 4-2. Component Value Weighting for Facility Likelihood Calculation .......................................4-5 Table 4-3. Summary of Facility Risk Assessment Results ....................................................................4-6 Table 5-1. Recommended 10-Year Replacement and Rehabilitation Program ..................................5-3 Table 5-2. Recommended Rehab/Replacement Program Details.......................................................5-4

LIST OF FIGURES
Figure 2-1. Example Capacity Deficiency Scenarios ............................................................................2-9 Figure 3-1. Existing Water System and Pressure Zones ......................................................................3-2 Figure 4-1. Pump Station Risk Assessment Methodology...................................................................4-1 Figure 4-2. Risk Level Matrix (PUMP Update) .....................................................................................4-2 Figure 4-3. Risk Levels of Assets, Percent of Total ..............................................................................4-4 Figure 4-4. Facility Risk Levels.............................................................................................................4-7 Figure 5-1. Action Plan Matrix.............................................................................................................5-1

LIST OF APPENDICES
Appendix A. Pump Performance Testing Results
Appendix B. Materials Testing Results
Appendix C. Component Risk Results, Rehab/Replacement Projects, and Action Plan by Facility Appendix D. Facility Risk Inputs and Outputs

Page 803 of 1105 ends

N-268-40-22-15-WP-R – AMP Addendum
iii City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table of Contents

LIST OF ACRONYMS AND ABBREVIATIONS
AMP Asset Management Plan 1-1
BEP Best Efficiency Point
City City of Fairfield 1-1
gpm Gallons Per Minute 2-5
PETS Pump Efficiency Testing Services 2-3
POR Preferred Operating Region
psi Pounds Per Square Inch 2-5
TDH Total Dynamic Head 2-3
V&A V&A Consulting Engineers 2-5

Page 804 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
1-1 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

1.0 INTRODUCTION

1.1 Background
In 2015, the City of Fairfield (City) undertook a condition and risk assessment of the City’s 16 potable water pump stations and two raw water pump stations. Results from the assessments were used to determine the functionality of the facilities and estimate the remaining useful life of the components. A risk-based system was developed to prioritize the most urgent improvements and define triggers that indicate when a pump station is ready for a maintenance or improvement action. The resulting Asset Management Plan (AMP) provided recommendations for an optimized preventative maintenance program and a rehabilitation/replacement program which specified recommended actions through 2020.

Since 2015, the City has implemented most of the high and medium priority recommendations from the AMP including both adjustments to maintenance practices and capital rehabilitation/replacement projects. The City now desires to update the AMP and develop a 10-year capital improvement plan for its water pump stations. This AMP update is presented as an Addendum to the 2015 AMP.

In March 2023, the City reported that the Rancho Solano 4 Pump Station experienced a catastrophic failure of the discharge manifold beneath the pump house slab. The failure was to assets not associated with this asset management plan update. The City is currently investigating the failed assets and the cause of the failure and will likely undertake a major rehabilitation of the facility. The evaluation of the Rancho Solano 4 Pump Station is included in this asset management plan update based on observations and analysis prior to the buried piping failure and the recommendations will be used to inform the scope of the rehabilitation of the facility.

1.2 Scope of Update
The AMP update includes assessment of 14 of the water pump stations evaluated in 2015 and an additional 2 pump stations not included in the 2015 evaluation. As shown in Table 1, each facility was visually assessed during a site visit and pump performance testing was performed to evaluate flow meter accuracy and to develop performance points (head and flow) of each pump. Additional assessment was performed as shown below:
• Detailed electrical assessments were performed at Rolling Hills, Rancho Solano Zone 4, and both the Rancho Solano Golf Course and Raw Water Pump Stations. Coating and steel thickness testing was performed at the Rancho Solano pumping stations, which were not assessed in 2015.
• A performance deficiency study was completed for pumps at several pump stations identified by the City.
• Facility capacity analyses were performed for Pressure Zones 2 and 4 to evaluate the existing pumping capacity of the Rolling Hills and Rancho Solano Zone 4 Pump Stations.

Page 805 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
1-2 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 1-1. Pump Station Facilities included in AMP Update Pumping Station Facility
Visual
Condition
Assessment
Pump
Performance
Testing
Capacity
Assessment
Pump
Deficiency
Assessment
Detailed
EI&C
Assessment
Coating
and Steel
Thickness
Testing
Facilities Assessed in 2015
Paradise Valley X X X
Rancho Solano Zone 5 X X
Mangels X X
Rolling Hills X X X X X
Martin Hill X X
Rancho Solano Zone 4(a) X X X X X
Eastridge X X
Southbrook #1 X X
Gold Ridge X X
Sanctuary Zone 3 X X
Sanctuary Zone 4 X X X
Rancho Solano Zone 3 X X
Southbrook #2 X X
South Cordelia X X
Facilities Not Fully Assessed in 2015 Study
Rancho Solano Golf Course X X X X
Rancho Solano Raw Water X X X X
(a) As mentioned above, Rancho Solano Zone 4 (RSZ4) was rehabilitated in 2023, after publishing of an earlier draft of this report. In the risk assessment sections of this report, RSZ4 is presented as ‘RSZ4’, which is the facility pre-rehabilitation and as ‘RSZ4 (2023)’, which is the facility after rehabilitation.

1.3 Structure of Addendum
This Addendum includes:
• Section 2 - Condition Assessment – Describes the visual and performance testing assessments that were performed on the 16 pump stations and provides a summary of results. Presents a pump deficiency analysis of select pumps based on direction of the City and outcome of the pump performance testing.
• Section 3 - Capacity Assessment – Describes the capacity assessment that was performed on the Rolling Hills and Rancho Solano Zone 4 Pump Stations and provides a summary of results. • Section 4 - Risk Assessment – Summarizes the risk assessment that was updated based on new condition assessment results and provides a summary of results. • Section 5 - Updated Asset Management Plan Recommendations – Presents a prioritized 10-year program based on condition and risk assessment results.

Page 806 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
1-3 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
In general, the methodology for each of these project tasks followed the same approach as the 2015 study.

In those cases, an overview summary of the methodology is provided. Where the approach was expanded upon or varied from the 2015 study, the detailed methodology is described.

Page 807 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-1 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

2.0 CONDITION ASSESSMENT
This chapter discusses the methodology used to assess the condition of the City’s pump stations and summarizes the assessment results.

2.1 Methodology
The condition assessment consisted of visual inspections, pump performance testing, and coating and steel thickness testing. The methodology for visual and pump performance testing followed the same approach as the 2015 study; these are summarized in the following sections. Coating and steel thickness testing methodology is discussed in detail.

2.1.1 Visual Condition Assessment
West Yost conducted site visits of the 16 pump stations between June 14 and June 21, 2022. The site visits were conducted by a condition assessment team that included the City’s Senior Instrumentation Technician, and engineers from West Yost. The team conducted visual inspections of the civil, structural, mechanical, electrical, and controls systems. The assessment team did not conduct confined space entries, destructive testing, or assessments of below grade piping, valves or appurtenances.

The team observed the external condition and performance of the facilities and equipment. Based on the observations, West Yost assigned a score to each component using the scoring index defined in Table 2-1 (Table 6 in 2015 AMP).

Table 2-1. Visual Condition and Performance Scoring Index Score Condition Score Index Performance Score Index(a)
1 Excellent Component functioning as Intended
2 Slight visible degradation In Service, but higher than expected O&M costs 3 Visible degradation In service, but function is impaired 4 Integrity of component moderately compromised In service, but function is highly impaired 5 Integrity of component severely compromised Component is not functioning as intended (a) Pump performance (capacity and efficiency) was assessed separately; see Section 2.2.2

2.1.2 Pump Performance Testing
Pump performance and efficiency testing was conducted by Pump Efficiency Testing Services (PETS) between June 14 and June 29, 2022. For each pump station, testing by PETS included the following:
• Pump Flow Tests – Testing included flow rate measurements using a portable ultrasonic flowmeter attached to the pump discharge piping, and suction and discharge pressure at three operating points. Measurements were taken for each pump at the City’s pump stations. The suction and discharge pressure measurements were used to calculate the total dynamic head (TDH) at each operating point.

Page 808 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-2 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
• Flow Meter Verification – Up to 15 measurements were taken using the ultrasonic flowmeter, which were used to compare with the flow rate indicated on the City’s flow meters to verify City meter accuracy.
• Thermal/Infrared Images – Thermal image photographs were taken of the control panels and included the breakers, transformers, relays, motor starters, and rectifiers. • Energy Cost Savings Analysis – Using the flow and TDH measured during the pump flow tests, an analysis was conducted for each pump to determine the viability of replacing the pump with a more efficient unit.

2.1.3 Materials Testing
Concrete and metal condition assessments were performed by West Yost’s subconsultant, V&A Consulting Engineers (V&A), on June 21, 2022 at Rancho Solano Raw Water and Rancho Solano Golf Course Pump Stations. The V&A assessment followed the same rating system as the visual assessment. The methodology is described in detail in Appendix B and summarized below.

Concrete surfaces were observed visually for cracks, delamination, corrosion, and other concrete defects.

The surfaces were documented using digital, still photographs. Additionally, concrete sounding was performed within the buildings at both facilities to investigate for shallow, subsurface discontinuities.

Sounding was conducted using a hammer to strike accessible concrete surfaces and observing the qualities of the sound returned.

The condition of various metallic piping was evaluated using ultrasonic testing to assess the wall thickness; the effects of corrosion are identifiable when the wall thickness is measured less than the maximum, based on new pipe. Additionally, dry film thickness testing was performed on metallic piping and equipment components to determine the extent of protective coating deterioration.

2.2 Analysis and Results
This section presents the results from the visual condition assessments, pump performance testing, pump capacity deficiency analysis, and materials testing.

2.2.1 Visual Condition Assessment
The results of the condition assessment for each pump station are summarized in Appendix C.

Most of the mechanical equipment is in similar condition as was documented in the 2015 assessment, with slightly further deterioration noted. Some of the equipment has been replaced since the last assessment.

Although many of the pumps have been rebuilt over the years, most of them have outlived the typical useful life for centrifugal pumps. In general, the piping was found to be in marginally good condition with localized corrosion and coating deterioration noted. Several of the rubber pipe couplings were found to be deteriorating and in need of replacement. Several of the isolation valves were found to be moderately corroded with some evidence of leakage and need repair or replacement. Much of the electrical, instrumentation, and controls equipment are now past the useful life and in need of replacement.

Page 809 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-3 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

2.2.2 Pump Performance Testing
This section presents the results of the performance testing completed for the pumps assessed and includes separate discussions for the capacity and efficiency observed for each pump.

2.2.2.1 Pump Capacity
Table 2-2 summarizes the measured flow and TDH and compares it to the pump name plate flow and TDH for each pump at each station. Appendix A presents the pump curves with the field-measured operating points indicated. Paradise Valley, Rancho Solano Zone 4, Rolling Hills, and Sanctuary 4 Pump Stations were identified by the City as having issues related to flow rates that are significantly less than the nameplate duty point. In addition to these four City-identified deficient stations, capacity deficiencies were observed at multiple other stations as part of the performance testing conducted. Deficient pumps are considered to be those delivering less than 82 percent of nameplate flow (deficient by over 18 percent). These pumps, along with the pumps at stations identified by the City as being deficient and are highlighted in Table 2-2.

These deficient pumps are analyzed in further detail in Section 2.2.3.2.

The City reported after performance testing that both pumps at Rancho Solano Zone 4 Pump Station are regularly operated with the downstream isolation valves in a partially throttled position. The pumps are normally operated in this manner to avoid amperage outside the service factor of 1.15 percent, which happens when the pumps are completely unthrottled. The normal pumping capacity under this operating condition is therefore much less than what could be achieved with fully unthrottled pumps.

It was also noted that the nameplate data for Pumps 1 through 3 at Goldridge Pump Station appear to conflict. More specifically, the nameplate flow and TDH are listed as 1000 gpm and 100’ TDH and the impeller diameter is listed as 10.69 gpm on each nameplate. However, based on the published pump curves, the listed nameplate flow and TDH should equate to an impeller diameter of approximately 12 inches. It is therefore unclear which pump curve should apply for these pumps. The measured operation points fall between the pump curves for a 10.69-inch and a 12-inch impeller diameter.

Page 810 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-4 City of Fairfield
Potable Water Pump Station – AMP Update
April 2023
Table 2-2. Pump Operation versus Nameplate Ratings
(Pumps performing greater than 18 percent below design operating point are highlighted in red) Pump
Station Pump
Measured
Flow, gpm
Nameplate
Flow, gpm
Difference in
Flow, gpm
(percent)
Measured
TDH, ft
Nameplate
TDH, ft
Difference in
TDH, ft
(percent)
South
Cordelia
P1 1901 1900 1 (0.1) 25 42.5 -17.5 (-41.2)
P2 1957 1900 57 (3) 23 42.5 -19.5 (-45.9)
P3 1972 1900 72 (3.8) 23 42.5 -19.5 (-45.9)
Gold Ridge
P1 960 1000 -40 (-4) 95 100 -5 (-5)
P2 942 1000 -58 (-5.8) 95 100 -5 (-5)
P3 914 1000 -86 (-8.6) 95 100 -5 (-5)
P4 1373 1385 -12 (-0.9) 104 110 -6 (-5.5)
Mangels
P1 295 360 -65 (-18.1) 150 137 13 (9.5)
P2 292 360 -68 (-18.9) 148 137 11 (8)
Martin Hill
P1 1121 1400 -279 (-19.9) 129 114 14.4 (12.6)
P2 1140 1400 -260 (-18.6) 141 114 26.4 (23)
P3 1066 1400 -334 (-23.9) 139 114 24.4 (21.3)
Paradise
Valley
P1 739 1400 -661 (-47.2) 123 100 17 (16)
P2 700 1400 -700 (-50) 125 100 19 (17.9)
P3 804 1400 -596 (-42.6) 127 100 21 (19.8)
Rolling Hills
P1 1010 1400 -390 (-27.9) 129 115 14 (12.2)
P2 1048 1400 -352 (-25.1) 129 115 14 (12.2)
P3 965 1400 -435 (-31.1) 129 115 14 (12.2)
South
Brook #1
P1 345 450 -105 (-23.3) 90 100 -10 (-10)
P2 360 450 -90 (-20) 97 100 -3 (-3)
P3 221 450 -229 (-50.9) 99 100 -1 (-1)
P4 872 1250 -378 (-30.2) 116 90 26 (28.9)
South
Brook #2
P1 328 450 -122 (-27.1) 99 105 -6 (-5.7)
P2 448 450 -2 (-0.4) 81 105 -24 (-22.9)
P3 412 450 -38 (-8.4) 81 105 -24 (-22.9)
P4 962 1250 -288 (-23) 81 100 -19 (-19)
Eastridge
P1 215 180 35 (19.4) 157 195 -38 (-19.5)
P2 190 180 10 (5.6) 157 195 -38 (-19.5)
P3 210 180 30 (16.7) 159 195 -36 (-18.5)
P4 1194 1250 -56 (-4.5) 185 195 -10 (-5.1)
Rancho
Solano
Zone 3
P1 530 705 -175 (-24.8) 240 245 -5 (-2)
P2 525 705 -180 (-25.5) 226 245 -19 (-7.8)
P3 555 705 -150 (-21.3) 231 245 -14 (-5.7)

Page 811 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-5 City of Fairfield
Potable Water Pump Station – AMP Update
April 2023
Table 2-2. Pump Operation versus Nameplate Ratings
(Pumps performing greater than 18 percent below design operating point are highlighted in red) Pump
Station Pump
Measured
Flow, gpm
Nameplate
Flow, gpm
Difference in
Flow, gpm
(percent)
Measured
TDH, ft
Nameplate
TDH, ft
Difference in
TDH, ft
(percent)
Sanctuary
Zone 3
P1 306 425 -119 (-28) 113 115 -2 (-1.7)
P2 211 425 -214 (-50.4) 88 115 -27 (-23.5)
P3 211 425 -214 (-50.4) 88 115 -27 (-23.5)
P4 786 1250 -464 (-37.1) 129 115 14 (12.2)
Rancho
Solano
Zone 4
P1 (a) 184 Not
Available (b)
194 Not
Available (b)
P2 (a) 249 Not
Available (b)
194 Not
Available (b)
Sanctuary
Zone 4
P1 236 270 -34 (-12.6) 132 135 -3 (-2.2)
P2 236 270 -34 (-12.6) 132 135 -3 (-2.2)
P3 671 1250 -579 (-46.3) 148 124 24 (19.4)
Rancho
Solano
Zone 5
P1 75 53.27 21.73
(40.8)
116 180 -64 (-35.6)
P2 65 53.27 11.73 (22) 132 180 -48 (-26.7)
P3 65 53.27 11.73 (22) 136 180 -44 (-24.4)
Rancho
Solano Golf
Course
P1 1446 1300 146 (11.2) 270 145 125 (86.2)
P2 1300 750 550 (73.3) 309 Not
Available
P3 679 500 179 (35.8) 316 Not
Available
Rancho
Solano Raw
Water
P1 424 600 -176 (-29.3) 153 176 -23 (-13.1)
P2 525 600 -75 (-12.5) 155 176 -21 (-11.9)
P3 449 600 -151 (-25.2) 153 176 -23 (-13.1)
P4 190 200 -10 (-5) 153 158 -5 (-3.2)
(a) After performance testing Pump 1 and Pump 2 were reported by the City as being normally operated in a partially throttled condition, as the motors will operate outside the 1.15% service factor if completely unthrottled. (b) Nameplates for Pump 1 and Pump 2 at Rancho Solano Zone 4 do not have flow or TDH values listed; therefore, assessment of the measured operating points at that facility with respect to pump nameplate data could not be conducted.

Page 812 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-6 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

2.2.2.2 Pump Efficiency
Table 2-3 summarizes the measured wire to water efficiency, the calculated pump efficiency, and the theoretical pump efficiency for each of the pumps included in this study. The theoretical pump efficiency is based on plots of the measured pump operating points on the manufacturer’s performance curves.

Appendix A presents the detailed results of the testing including observed operating flow and head plotted on the pump curves used to estimate theoretical efficiency.

As discussed in the 2015 assessment, a typical clean water pump should have an efficiency of approximately 70 percent or greater when operating at its design point. Of the 55 pumps assessed, 31 had calculated efficiencies less than 70 percent, indicating significantly diminished operating efficiencies.

The 31 pumps and their facilities are highlighted in Table 2-3. The reduced efficiencies generally can be attributed to the pumps operating at points divergent from the associated nameplate duty point.

The 31 pumps and their facilities are highlighted in Table 2-3.

Table 2-3. City of Fairfield Pump Station Wire to Water Efficiency Pump Station Pump
Measured
Wire to Water
Efficiency
Calculated
Pump
Efficiency
Theoretical
Pump
Efficiency (a)
Delta,
percent
South Cordelia
P1 0.44 0.47 (c) 0.85 -38.4
P2 0.38 0.41 (c) 0.85 -43.8
P3 0.40 0.43 (c) 0.85 -41.5
Gold Ridge
P1 0.68 0.74 0.82 -7.8
P2 0.67 0.72 0.82 -10.4
P3 0.67 0.72 0.82 -9.7
P4 0.65 0.68 (c)
Mangels
P1 0.67 0.77 0.76 1.1
P2 0.66 0.74 0.75 -1.3
Martin Hill
P1 0.40 0.76 0.85 -9.3
P2 0.78 0.83 0.85 -2.1
P3 0.75 0.80 0.85 -5.4
Paradise Valley
P1 0.59 0.65 (c) 0.81 -15.7
P2 0.57 0.63 (c) 0.77 -14.3
P3 0.68 0.71 0.78 -6.7
Rolling Hills
P1 0.68 0.74 0.85 -11.4
P2 0.71 0.76 0.85 -9.2
P3 0.68 0.74 0.84 -10.5
South Brook 1
P1 0.56 0.59 (c) 0.75 -16.4
P2 0.61 0.66 (c) 0.75 -9.0
P3 0.46 0.50 (c) 0.6 -10.4
P4 0.69 0.72 0.83 -10.9

Page 813 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-7 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 2-3. City of Fairfield Pump Station Wire to Water Efficiency Pump Station Pump
Measured
Wire to Water
Efficiency
Calculated
Pump
Efficiency
Theoretical
Pump
Efficiency (a)
Delta,
percent
South Brook 2
P1 0.56 0.57 (c) 0.73 -12.8
P2 0.54 0.58 (c) 0.73 -12.3
P3 0.51 0.54 (c) 0.73 -16.4
P4 0.45 0.48 (c) 0.76 -36.0
Eastridge
P1 0.57 0.61 (c) 0.73 -8.7
P2 0.49 0.54 (c) 0.73 -16.3
P3 0.56 0.61 (c) 0.73 -9.4
P4 0.71 0.75 0.81 -5.4
Rancho Solano Zone 3
P1 0.61 0.64 (c) 0.70 -5.5
P2 0.57 0.61 (c) 0.70 -9.0
P3 0.62 0.66 (c) 0.70 -4.0
Sanctuary Zone 3
P1 0.62 0.67 (c) 0.70 -3.2
P2 0.38 0.41 (c) 0.70 -29.0
P3 0.38 0.47 (c) 0.70 -23.2
P4 0.62 0.65 (c) 0.70 -5.3
Rancho Solano Zone 4
P1 0.61 0.68 (c) 0.75 -7.1
P2 0.71 0.79 0.77 1.6
Sanctuary Zone 4
P1 0.60 0.65 (c) 0.77 -11.5
P2 0.60 0.65 (c) 0.77 -11.5
P3 0.60 0.64 (c) 0.75 -11.2
Rancho Solano Zone 5
P1 0.53 0.64 (c) (b)
P2 0.52 0.63 (c) (b)
P3 0.54 0.64 (c) (b)
Rancho Solano Golf Course
P1 0.67 0.71 (d)
P2 0.71 0.76 (d)
P3 0.65 0.72 (d)
Rancho Solano Raw Water
P1 0.57 0.63 (c) (d)
P2 0.65 0.72 (d)
P3 0.71 0.78 (d)
P4 0.65 0.73 (d)
(a) Theoretical pump efficiency is based on plots of the measured pump operating points against the published pump curve. (b) Pumps at Rancho Solano Zone 5 Pump Station are new Grundfos pumps on a new skid. Pump curves have not been provided by the manufacturer.
(c) Calculated pump efficiency for indicated pump is less than the 70 percent efficiency typical for clean water pumps. (d) For the golf course and raw water pump stations, the City is primarily concerned with the physical condition of the pumps. Therefore, theoretical pump efficiency assessments were not performed.

Page 814 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-8 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

2.2.3 Preliminary Operational Analysis
Pump operation was analyzed based on pump curve performance and pump performance within the modelled system curve.

2.2.3.1 Preliminary Operational Analysis – Pump Curves
The first step to analyzing the operational performance was to assess the TDH and flowrate measured for each of the individual pumps and compare these values to the manufacturer’s published pump curve. A capacity deficiency could be indicated by two general scenarios, depending on where a given pump is operating relative to the published pump curve. Figure 2-1 illustrates the two general scenarios, which are further described below.

Scenario 1 is when the pump is operating along the pump curve, but farther to the left compared to the nameplate duty point. In this scenario, the actual flow rate is less than the nameplate flow, and the actual TDH is greater than the nameplate TDH. This scenario generally suggests greater head loss downstream of the pump moving performance left of the design operating point.

Factors that could cause increased frictional losses include but are not limited to:
• Valves that are inadvertently throttled instead of being completely open • Scale buildup on the interior walls of the pipelines
• Sediment accumulation along the length of the pipelines.

Scenario 2 is when the pump is operating at a point divergent from the pump curve with an actual flow rate that is less than the nameplate flow. In this scenario, the actual TDH could be more or less than the nameplate TDH, but since the pump is operating at a point below the pump curve, it is generally an indication that the pump has deteriorated to some degree.

Factors that could cause divergence of the pump performance from the manufacturer’s pump curve include but are not limited to:
• Recirculation of water within the pump due to worn seal rings between the impeller and the volute
• Wear or damage to the impeller
• Poorly seated valves of the non-operating pumps allowing some water to recirculate to the suction side
• Pump motor operating at speeds less than the design nameplate speed

Page 815 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-9 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Figure 2-1. Example Capacity Deficiency Scenarios
In addition to the pump performance testing results, data provided by the City was also used for four deficient stations identified by the City. City data for each pump station included actual overall flow rate in gallons per minute (gpm), and suction and discharge pressure in pounds per square inch (psi). The flow and pressure data were recorded by the City in five-minute increments between the dates of September 1, 2021, through September 1, 2022. This data did not distinguish flow and pressure per each individual pump, but rather was cumulative for the entire pump station. The data for Rancho Solano Zone 4 Pump Station included flow data for the date range listed above, but only included discharge pressure through May 5, 2022, and did not include any suction pressure data. Since the City data did not distinguish flow and pressure for the individual pumps, it was used primarily as a means to validate the results of the pump performance testing. Validation was accomplished by inferring which data points applied to a single pump operating; these specific data points were then compared to the operation points obtained from the pump performance testing.

As previously illustrated in Table 2-2, the measured flow rate for many of the pumps consistently differs from the associated nameplate flow. Table 2-4 presents a summary of the preliminary performance observations for these deficient pumps evaluated.

Page 816 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-10 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 2-4. Preliminary Pump Deficiency Observations
Pump Station Observations
Mangels • Pumps 1 and 2 operate at points that closely follow the pump curve and produce approximately 81 percent of the nameplate flow. (Scenario 1) Martin Hill • Pumps 1, 2 and 3 operate at points that closely follow the pump curve and produce approximately 76–81 percent of the nameplate flow. (Scenario 1) Paradise Valley • Pumps 1, 2 and 3 operate at points slightly below the pump curve and produce approximately 50–57 percent of the nameplate flow. (Scenario 1) Rolling Hills • Pumps 1, 2 and 3 operate at points slightly below the pump curve and produce approximately 69–75 percent of the nameplate flow. (Scenario 1) South Brook 1
• Pumps 1 and 2 operate at points below the pump curve and produce approximately 77-80 percent of the nameplate flow. (Scenario 2) • Pump 3 operates at a point below the pump curve and produces approximately 50 percent of the nameplate flow. (Scenario 2) • Pump 4 operates at a point that closely follows the pump curve and produces approximately 49 percent of the nameplate flow. (Scenario 1) South Brook 2 • Pumps 1 and 4 operate at points below their respective pump curve and produce approximately 73–77 percent of the nameplate flow. (Scenario 2) Rancho Solano Zone 3 • Pumps 1, 2 and 3 operate at points slightly below the pump curve and produce approximately 75–79 percent of the nameplate flow. (Scenario 1) Sanctuary 3
• Pump 1 operates at a point that closely follows the pump curve and produces approximately 72 percent of the nameplate flow. (Scenario 1) • Pumps 2 and 3 operate at points below the pump curve and produce approximately 50 percent of the nameplate flow.(Scenario 2) • Pump 4 operates at a point that closely follows the pump curve and produces approximately 63 percent of the nameplate flow. (Scenario 1) Rancho Solano Zone 4 • Pumps 1 and 2 operate at points below the pump curve. No nameplate data to compare.

Sanctuary 4
• Pumps 1 and 2 operate at points slightly below the pump curve and produce approximately 87 percent of the nameplate flow. (Scenario 1) • Pump 3 operates at points that closely follow the pump curve and produces approximately 54 percent of the nameplate flow. (Scenario 1) Rancho Solano Raw Water
• Pumps 1 and 3 are observed to be deficient with respect to flow rate, producing approximately 71 and 75 percent of the nameplate flow, respectively. A detailed pump curve analysis was not conducted for this facility, as it is not owned by the City. Based on Pumps 1 and 3 also operating with less TDH than indicated on the nameplate, it is concluded there are no throttled valves or unintended additional TDH in the system, and that Pumps 1 and 3 are therefore operating below the pump curve (Scenario 2)
Southbrook 1 and 2 pump stations discharge to hydropneumatics tanks such that the system curve is flat delivering steady flow and head. Rancho Solano Raw Water pump station is not owned by the City and is not a part of the City’s hydraulic model. No additional analysis was performed to evaluate performance along the system curve at these facilities.

Page 817 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-11 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
For the deficient pumps that operate on the pump curve but at higher TDH than the nameplate value, as a starting point it is recommended that the City confirm there are no valves that are inadvertently throttled downstream of the pumping station. As previously discussed, this is a common way for increased frictional losses to be induced into a pumping system and can be easily corrected. Additionally, for deficient pumps that are operating at points that are divergent from the pump curve, it is recommended to pull the pump and check the seal ring and impeller to verify whether they are damaged or worn; another recommendation is to verify whether the valves on the non-operating pumps are properly seated and do not allow recirculation.

These recommendations are included in Appendix C with a zero-cost value (recommended for Increased Maintenance/Operational Adjustments). It is assumed the recommendation will be performed as a maintenance effort.

The remaining pumps are further evaluated for system performance in Section 2.2.3.2.

2.2.3.2 Secondary Operational Analysis – System Curves
A secondary analysis was performed for facilities identified in Table 2-4 with the exception of Southbrook Pump Station 1 and 2 and Rancho Solano Raw Water as noted earlier. Using the City’s hydraulic model of the distribution system, West Yost developed system curves to determine the proper operating range along the pump curve. System curves were developed for a range of scenarios and was overlayed with the published pump curves to identify the range along the pump curve that the pumps should actually perform. This can confirm whether the pump is theoretically a suitable selection for the given system. A good selection is indicated by the point of intersection falling within the pump’s preferred operating region (POR), whereas a poor selection is indicated by a point of intersection falling outside the pump’s POR. A typical POR commonly accepted in the industry for centrifugal pumps is defined as a flow rate between 70 percent to 120 percent of the flow at the best efficiency point (BEP).

Following the assessment of the published pump curve relative to the modeled system curve, West Yost then considered the operating points measured during the recent pump performance testing with respect to the system curve. This step involved assessing where the operating points are located graphically with respect to the modeled system curve. If the operating points fall within the range of modeled system curves, it is a good indication that the City is operating the overall system in a consistent manner as assumed for preparation of the hydraulic model. If the operating points fall outside of the range of system curves, it is likely that the system is being operated in a manner that is inconsistent with the model. For example, valves could be unintentionally throttled, or additional flow could have been introduced at a location downstream from the pump station – both of these scenarios would result in additional TDH (and less flow) than expected based on the intersection of the system and pump curves. Plots of the modeled system curves overlaid with the published pump curves and measured operating points are provided with Appendix A.

Table 2-5 summarizes the results of the pump and system curve analysis, identifying pumps performing within the system curve range and also identify if the POR is within that range. Pumps should be operating within the system curve range and ideally the POR will as well for greatest efficiency.

Page 818 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-12 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 2-5. Pump and System Observations
Pump Station, Pump No.

Actual Performance Within System
Curve Range (Y/N)
Published Pump POR Within
System Curve Range (Y/N)
Rancho Solano Zone 4, P1 Yes No
Rancho Solano Zone 4, P2 Yes No
Sanctuary 4, P1 Yes Yes
Sanctuary 4, P2 Yes Yes
Sanctuary 4, P3 Yes No
Rancho Solano Zone 3, P1 No Yes
Rancho Solano Zone 3, P2 No Yes
Rancho Solano Zone 3, P3 No Yes
Sanctuary 3, P1 Yes No
Sanctuary 3, P2 No No
Sanctuary 3, P3 No No
Sanctuary 3, P4 Yes No
Mangels, P1 No No
Mangels, P2 No No
Rolling Hills, P1 No No
Rolling Hills, P2 No No
Rolling Hills, P3 No No
Martin Hill, P1 No No
Martin Hill, P2 No No
Martin Hill, P3 No No
Paradise Valley, P1 No No
Paradise Valley, P2 No No
Paradise Valley, P3 No No
Combining the results of the assessments described above and summarized in Tables 2-4 and 2-5 provide a relationship between two main points: whether the pump is operating on its pump curve; and whether the pump is operating within a range of flow/TDH that should be expected based on the modeled system curves. Different recommendations are drawn based on the answers to these two questions and can be generalized based on the four cases below.

General Scenario 1: Pump is operating on or very near its published pump curve and POR is within the range of modeled system curves. If measured operation is also within the range of modeled system curves, no action is recommended. If measured operation is outside the range of modeled system curves, further investigations are recommended.

Page 819 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-13 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
General Scenario 2: Pump is operating on or very near its published pump curve and POR is outside the range of modeled system curves. Since POR is outside the range of modeled system curves, pump replacement with one with a better fitting POR is typically recommended. Common issues under this scenario include additional frictional loss in the form of throttled valves, scale buildup, smaller piping diameter than what has been recorded, introduction of an undocumented flow addition downstream of the station.

General Scenario 3: Pump is operating off its published pump curve and POR is within the range of modeled system curves. Since the pump selection is theoretically suitable for the modeled system under this scenario, typical causes for operation off the pump curve include wear on the impeller, recirculation of flow through isolation valves or through the station PRV.

General Scenario 4: Pump is operating off its published pump curve and POR is outside the range of modeled system curves. Since POR is outside the range of modeled system curves, pump replacement with one with a better fitting POR is typically recommended.

This is illustrated in Table 2-6 below.

Table 2-6 General Pump Operating Scenarios
General Scenario Pump Operating on Performance Curve POR is within System Curves 1 Yes Yes
2 Yes No
3 No Yes
4 No No
For all cases, if the POR (between 70 percent and 120 percent of the BEP flow) falls within the range of modeled system curves, it is an indication of a good pump selection for the given system; similarly, if the POR falls outside the range of modeled system curves, it is an indication of a poor pump selection.

Table 2-7 summarizes the general scenarios and recommendations for each pump analyzed.

Table 2-7. Pump and System Conclusions and Recommendations Pump Station, Pump No.

General
Scenario Conclusion / Recommendation
Rancho Solano Zone 4, P1 and P2 4
• Conclusion: Full flow performance amperage is outside the motor service factor – both pumps must be throttled so
that electrical current is within acceptable limits.
• Recommendation: Replace both pumps.

Sanctuary 4, P1 and P2 3
• Conclusion: Flow demand is satisfied by existing pump output; pump performance curve overlaps range of
modeled system curves; actual operation points measured in field deviate significantly from the published
performance curve, indicative of different pumps
altogether.

Page 820 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-14 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 2-7. Pump and System Conclusions and Recommendations Pump Station, Pump No.

General
Scenario Conclusion / Recommendation
• Recommendation: Continue operating pumps to failure;
coordinate with manufacturer to verify correct pump curve.

Sanctuary 4, P3 2
• Conclusion: Flow demand is satisfied by existing pump output; pump performance curve overlaps range of
modeled system curves; measured operating points are
very close to the published performance curve, and far to the left of the published BEP (i.e., outside of the POR). • Recommendation: Continue operating pump to failure.

Rancho Solano Zone 3, P1, P2 and
P3 3
• Conclusion: Flow demand is satisfied by existing pump output; pump performance curve overlaps range of
modeled system curves; measured operating points are
slightly lower than the published performance curve, and far to the left of the published BEP (i.e., outside of the POR) • Recommendation: Continue operating pumps to failure;
assess the pumps for wear on the impellers and rotating parts; assess the isolation valves to be sure there is no recirculation.

Sanctuary 3, P1 2
• Conclusion: Flow demand is satisfied by existing pump output; pump performance curve does not overlap range
of modeled system curves (high static head conditions not met); measured operating points are very close to the
published performance curve, and far to the left of the published BEP (i.e., outside of the POR).
• Recommendation: Replace the pump.

Sanctuary 3, P2 and P3 4
• Conclusion: Flow demand is not satisfied by existing pump output; pump performance curve does not overlap range
of modeled system curves (high static head conditions not met); actual operation points measured in field deviate significantly from the published performance curve,
indicative of different pumps altogether.
• Recommendation: Replace the pumps.

Sanctuary 3, P4 2
• Conclusion: Flow demand is met by existing pump output; pump performance curve overlaps range of modeled
system curves; measured operating points are very close to the published performance curve, and far to the left of the published BEP (i.e., outside of the POR).
• Recommendation: Continue operating pump to failure.

Mangels, P1 4
• Conclusion: Flow demand is satisfied by existing pump output; pump performance curve does not overlap range
of modeled system curves (low static head conditions not met); measured operation points are very close to the
published performance curve, and very close to the
published BEP (i.e., within the POR).

Page 821 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-15 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 2-7. Pump and System Conclusions and Recommendations Pump Station, Pump No.

General
Scenario Conclusion / Recommendation
• Recommendation: Install VFD and/or pressure controls to better satisfy low static head conditions and run pump to failure; alternatively, replace the pump.

Mangels, P2 4
• Conclusion: Flow demand is satisfied by existing pump output; pump performance curve does not overlap range
of modeled system curves (low static head conditions not met); actual operation points measured in field are
significantly lower than the published performance curve, and very close to the published BEP.
• Recommendation: Install VFD and/or pressure controls to better satisfy low static head conditions and run pump to failure; alternatively, replace the pump.

Rolling Hills, P1, P2 and P3 2
• Conclusion: Flow demand is met by existing pump output; pump performance curve overlaps range of modeled
system curves; measured operating points are very close to the published performance curve, and very close to the
published BEP.
• Recommendation: Continue operating pumps to failure.

Martin Hill, P1, P2 and P3 2
• Conclusion: Flow demand is met by existing pump output; pump performance curve overlaps range of modeled
system curves; measured operating points are very close to the published performance curve, and very close to the
published BEP.
• Recommendation: Continue operating pumps to failure.

Paradise Valley, P1 and P3 2
• Conclusion: Flow demand is met by existing pump
output; pump performance curve overlaps of modeled
system curves; measured operating points are very close to the published performance curve, and far to the left of the published BEP.
• Recommendation: Continue operating pumps to failure.

Paradise Valley, P2 4
• Conclusion: Flow demand is satisfied by existing pump output; pump performance curve overlaps range of
modeled system curves; measured operating points are
significantly lower than the published performance curve, and far to the left of the published BEP.
• Recommendation: Continue operating pump to failure;
assess the pump for wear on the impellers and rotating
parts; assess the isolation valves to be sure there is no recirculation.

Page 822 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-16 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Where pump replacement is being recommended in Table 2-7, the duty point (flow/TDH) should be established, and replacement pump should be specified during design or following a detailed analysis of the hydraulic system and the overall station and pressure zone requirements. Similarly, where it is recommended to continue to run a pump to failure, a design or detailed analysis should also be performed once replacement is warranted.

Since desired pump performance was analyzed based on the City’s hydraulic model which assumes that all valves are not throttled for flow control and most pressure control stations are set at 40 psi (Rancho Solano 4 is set to 25 psi) West Yost recommends a field confirmation of isolation valves immediately downstream of each pump station to confirm if, and how much, valves may be throttled and the actual setting at control stations. Actual valve positioning and pressure control settings should be incorporated into the hydraulic model, new system curves developed, and pump recommendations provided in Table 2-7 confirmed. All pressure control stations should be confirmed. Table 2-8 illustrates the valves immediately downstream of the pump stations that should be investigated for control positioning.

Table 2-8. System Valves Immediately Downstream of Pump Station Facility ID Facility Name Valve ID
ERPS Eastridge Pump Station WGV-15054, WGV-15055, WGV-15079 GRPS Gold Ridge Zone II Pump Station WBV-10610, WGV-14990 MGLPS Upper Mangels Zone II Pump Station WGV-14372, WGV-14373, WGV-18615, WBV-10659 MHPS Martin Hill Zone II Pump Station WGV-12680, WGV-13945, WGV-13953, WGV-14080, WGV-18088
PVPS Paradise Valley Zone II Pump Station WGV-10352, WBV-10084 RHPS Rolling Hills Pump Station WBV-10259, WGV-15139
RSGC Rancho Solano Golf Course Pump Station N/A
RSRAW Rancho Solano Raw Water Pump Station WGV-10564, WGV-12441, WGV-12265 RSZ3PS Rancho Solano Zone III Pump Station WGV-15121, WGV-15122, WGV-12258, WGV-12259, WGV-12260
RSZ4 Rancho Solano Zone IV Pump Station WGV-11268, WGV-11269, WGV-11263, WGV-17283, WGV-11270
RSZ5 Rancho Solano Zone V Pump Station WGV-11330, WGV-15045 SANC3 Sanctuary Zone III Pump Station WGV-18447, WGV-15409 SANC4 Sanctuary Zone IV Pump Station WGV-12731, WBV-10230, WGV-15046 SB1 Southbrook Unit 10 Zone II Pump Station #1 WBV-10036, WBV-10066, WBV-10073 SB2 Southbrook Unit 10 Zone II Pump Station #2 WGV-15050, WGV-15051, WGV-19024 SCPS South Cordelia Pump Station WGV-15064

Page 823 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
2-17 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

2.2.4 Materials Testing
The results of the materials testing for the Rancho Solano Golf Course and Rancho Solano Raw Water Pump Stations are presented in Appendix B. Materials evaluated included concrete, metal, and electrical components at the stations.

2.2.4.1 Rancho Solano Golf Course Pump Station
The concrete tested at Rancho Solano Golf Course was found to be in good condition with little to no corrosion. Sounding was performed on the station’s wall and floor, and no signs of concrete spalling or delamination were observed during the assessment. The metal components and piping tested, excluding the electrical cabinets, were found to have minor to severe corrosion. The electrical cabinets were found to have severe corrosion. Photos 2-1 and 2-2 depict typical corrosion activity of piping/appurtenances and cabinets.

Photo 2-1
Ductile Iron Tee Exhibiting Minor to Severe Corrosion
Photo 2-2
Metal Electrical Cabinet Exhibiting Severe Corrosion

2.2.4.2 Rancho Solano Raw Water Pump Station
In summary, the concrete surfaces and metal piping assessed were found to be in good condition with little or no corrosion. The discharge piping, pump, and platform had recently been recoated. The coating was in good condition on the interior and exterior piping. The electrical cabinet and metal platform were in good condition with no observed defects. The concrete masonry walls and concrete floors were in good condition.

Page 824 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
3-1 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

3.0 CAPACITY ASSESSMENT
City staff identified the Rolling Hills and Rancho Solano Zone 4 Pump Stations as having possible electrical performance issues that would require upgrades to mitigate. If electrical upgrades are needed, the City intends to upgrade the electrical capacity to serve pumps sized for future buildout demand conditions.

This chapter describes the assessment performed to estimate future pumping capacity requirements of these facilities.

3.1 Assessment Approach
Pumping capacity is generally evaluated by pressure zone. Sufficient water delivery capacity into each zone should be provided by the City to meet the customer demands within the pressure zone. As shown in Figure 3-1, the Rolling Hills Pump Station, in coordination with the Paradise Valley and Martin Hill Pump Stations, serves Pressure Zone 2D. Rancho Solano Zone 4 Pump Station, along with Sanctuary 4 Pump Station, serves Pressure Zone 4. Therefore, the capacity of all pump stations serving Pressure Zones 2D and 4 were considered in this analysis.

A comparison of the available pumping capacity to the required future pumping capacity within Pressure Zones 2D and 4 are presented in this chapter. The assessment criteria, including pumping capacity requirements and buildout water demands, are described below.

3.1.1 Pumping Capacity Requirements
Sufficient pumping capacity, in conjunction with water storage reservoirs, should be provided by the City to meet peak customer water demands. As described in Section 3.1, the Rolling Hills and Rancho Solano Zone 4 Pump Stations serve Pressure Zones 2D and 4, respectively. Pressure Zones 2D and 4 are also served by additional pump stations and storage reservoirs, as shown in Figure 3-1.

Water system pumping capacity should be provided to meet the demands of the pressure zone. For zones with storage reservoirs, sufficient pumping capacity should be provided to meet the maximum day demand for the pressure zone. Water demands in excess of the maximum day demand (e.g., peak hour demand) are assumed to be supplied by the storage reservoirs.

The pump facility capacity analysis should also be conducted assuming the largest booster pump is out of service at each pump station (i.e., firm capacity of the pump station). This assumption ensures reliable deliveries during high demand conditions.

It is generally assumed that all pump stations serving a pressure zone are available to supply the zone.

This condition applies to Pressure Zone 4, which is supplied by both the Rancho Solano 4 and Sanctuary 4 Pump Stations. Based on discussions with the City, Pressure Zone 2D is not equally supplied by all three Zone 2D pump stations. Therefore, Zone 2D should be evaluated by regions of pump station influence— the west side of Zone 2D is primarily served by the Martin Hill Pump Station and the east side of Zone 2D is primarily served by the Rolling Hills and Paradise Valley Pump Stations. The Rolling Hills and Paradise Valley Pump Stations area of influence is assumed to encompass the eastern side of Pressure Zone 2D, with a western boundary running through the single 16-inch pipeline in Hillborn Road, between Sanctuary Drive and Fieldcrest Avenue. The Martin Hill Pump Station is generally unable to influence the areas to the east of this pipeline. Therefore, the pumping capacity analysis for Pressure Zone 2D, to include Rolling Hills Pump Station alone, was conducted for “2D East”.

Page 825 of 1105 ends

See
Detail
Map
80 80
680
12 12
12 ERR
GRPS
MGLPS
MGLR
MHPS
MHR
NHR
PVPS
RSPS4
RSR3
RSPS5
RTPS
RHPS
SANC4
SANC3
SCPS
SBPS1
SBPS2
WTMR
RSR4
SCR
ERPS
RSPS3
RHR
CHR
PVR
GRR
WTM
NBR
03,0006,000
ScaleinFeet
Zone2D
West-EastBoundary
Zone2DEast
Zone4
RollingHills
PumpStation
80 RanchoSolano
4Reservoir
RollingHills
Reservoir
Paradise
Valley
Reservoir
Paradise
ValleyPump
Station
RanchoSolano
4Pump
Station
Sanctuary4PumpStation
Figure3-1
ExistingWaterSystem
andPressureZones
CityofFairfield
PotableWaterPumpStation
AssetManagementPlanUpdate
WaterSystem
WaterTreatmentPlant
PumpStation
Reservoir
DistributionPipeline(≤12-inches)
TransmissionPipeline(>12-inches)
PressureZones
Zone1
Zones2A,2B,2C,2D,2E
Zones3A,3B
Zone4
Zone5
DetailMap
PumpStationsEvaluated
PressureZonesEvaluated
WEST YOST - N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\GIS\MXD\Fig3-1_11x17.mxd - ktiano - 12/5/2022 12 37
121
29 1229
29 128
12 680
80 Cordelia
Dixon
Fairfield
Martinez
Napa
Vacaville
Vallejo
DetailMap-Scale:1in=3,000ft

Page 826 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
3-3 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

3.1.2 Water Demands by Pressure Zone
Pumping capacity requirements are established based on water demands, as described in Section 3.1.1.

Existing water demands within Pressure Zones 2D and 4 were estimated using the City’s water system hydraulic model. Future additional demand expected at buildout was based on input from the City.

Existing and projected buildout water demands are further discussed in this section.

Existing water demands in Pressure Zones 2D and 4 were estimated using spatially located water meter data developed for the hydraulic model. Metered customer water demands were allocated into the hydraulic model in 2017 during hydraulic model development (using 2016 historical demands) and in 2020 during the latest hydraulic model update (using 2019 historical demands). Historical 2019 demands were slightly higher than historical 2016 demands (4 percent and 22 percent, respectively, for Zones 2D and 4). The slight increase in water demand from 2016 to 2019 would be anticipated based on a slight rebound in water consumption following the statewide 2012-2016 drought. Therefore, historical 2019 maximum day water demands of 1,870 gpm in Zone 2D and 450 gpm in Zone 4 were used as the baseline existing water demand for the pumping capacity evaluation.

Planned buildout land uses within Zones 2D and 4 were provided by the City via email on July 5, 2022. Neither zone was noted to have any known future development that should be considered as part of the pumping analysis. Therefore, no additional water demand due to buildout of the Pressure Zones was considered.

3.2 Results
Table 3-1 compares the existing available pumping capacity with the required pumping capacity for Zones 2D (East) and 4. Zone 2D East has an available firm pumping capacity of 5,600 gpm compared to an existing maximum day demand of 1,870 gpm, resulting in a surplus of 3,730 gpm, or approximately 200 percent of excess capacity. Similarly, Zone 4 has an available firm pumping capacity of 797 gpm compared to an existing maximum day demand of 450 gpm, resulting in a surplus of 347 gpm, or approximately 77 percent of excess capacity. As described previously, there is little to no new future development identified in Zones 2D and 4. Therefore, sufficient pumping capacity exists to meet the existing and future buildout demand. No capacity upgrades are recommended until the projected future maximum day demands exceed the surplus capacity presented in Table 3-1.

This capacity evaluation assumes full design performance ability of the existing pumps. The individual pumping capacity presented in Table 3-1 is based on each pump’s design operating point. During discussions with the City, it was noted that the Rolling Hills and Rancho Solano 4 Pump Stations are regularly operating at a lower capacity than is shown in the table. The reduced actual capacity exhibited by the pumps could be due to the pumps not operating near their design points or could be due to reduced efficiency caused by general wear and tear. Causes for and recommendations to improve the reduced pumping capacity are discussed in Chapter 2. Recommendations provided in Chapter 2 should be implemented. If pumps are replaced, a minimum capacity equal to the required pumping capacity noted in Table 3-1 should be provided.

Page 827 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
3-4 City of Fairfield
Potable Water Pump Station – AMP Update
April 2023
Table 3-1. Existing Pumping Capacities by Pressure Zone and Service Area Pressure Zone
Pump
Station
Pump
Numb
er
Pump
Capacity(a),
gpm
Total
Pumping
Capacity,
gpm
Firm
Pumping
Capacity(
b)
, gpm
Availabl
e
Pumping
Capacity
(c)
, gpm
Required
Pumping
Capacity
(d,e),gpm
Pumping Capacity
Available for Future
Growth
Surplus
(Deficit),
gpm
Surplus,
percent
of
existing
2D East(f)
Paradise
Valley
1 1,400
4,200 2,800
5,600 1,870 3,730 199
2 1,400
3 1,400
Rolling Hills
1 1,400
2 1,400 4,200 2,800
3 1,400
4 Rancho
Solano 4
1 257
514 257
797 450 347 77
2 257
Sanctuary 4
1 270
2 270 1,790 540
3 1,250
(a) Pump capacity corresponds to the design point of each pump. (b) Firm pumping capacity is defined as the total pumping capacity with the largest pump unit at each facility out of service. (c) Available pumping capacity assumes firm pumping capacity at all pump stations. (d) Required pumping capacity is equal to the maximum day demand of the pressure zone (for zones with storage, such as Zones 2D and 4), in addition to the maximum day demand of any pressure zones without storage that are served from the zone (e.g., Zone 4 includes the maximum day demand of the upper Zone 5, which does not have storage). In zones with storage, water demand greater than the maximum day demand (e.g., peak hour demand, fire flows) is drawn from water storage reservoir(s). It is assumed that the City’s Pressure Zone 2D and 4 water storage reservoirs have adequate storage available to serve emergency, fire, and operational storage requirements.
(e) The maximum day demand presented is based on metered average day demand spatial distribution from 2019, scaled to historical (2019) maximum day demand.
(f) Based on discussions with the City, the required pumping capacity for Zone 2D considers only the eastern portion of the pressure zone that is directly served by the Rolling Hills and Paradise Valley Pump Stations. Although the Martin Hill Pump Station also supplies the western portion of Zone 2D, the east and west areas of Zone 2D are only connected by a single 16-inch pipeline in Hillborn Road that isolates each side of the zone. Martin Hill Pump Station is generally unable to influence the areas to the east of this pipeline.

Page 828 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
4-1 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

4.0 RISK ASSESSMENT
This chapter describes the updated risk assessment that was used to prioritize the replacement or rehabilitation actions for both components and pump stations.

4.1 Methodology
The 2015 risk assessment developed likelihood of failure, consequence of failure, and risk scores for each individual component asset, and each pump station as a whole. During preparation of this AMP Update, the City initiated an update to their Potable Water Master Plan (PUMP), which included condition and risk assessment of other asset types (pipelines, reservoirs, treatment plants). As part of the PUMP Update, a risk assessment methodology was developed, which differed from the 2015 AMP. The City agreed to employ the risk methodology developed during the PUMP Update in this AMP Update1. The general approach is illustrated in Figure 4-1. As indicated in the figure, a rating for both likelihood and consequence of failure was given to each individual component asset (bottom row). The likelihood and consequence of failure methodologies for components as defined in the 2015 risk assessment have been maintained in this AMP Update. The aggregate of the likelihood results from components within a given pump station is then used to determine the likelihood of a pump station failure. Pump station likelihood is then combined with the consequence of failure rating of each pump station to determine a comprehensive risk rating for each pump station as a whole.

Figure 4-1. Pump Station Risk Assessment Methodology
Components and pump stations are then assigned a risk level, from Low to High, based on a risk level matrix. The PUMP Update also refined the City’s risk level matrix from the 2015 AMP; the updated risk level matrix is presented in Figure 4-2.
1 The primary reason for employing the PUMP Update risk approach was that the 2015 AMP study evaluated pump station likelihood of failure using a relative ranking of the components in that pump station compared to all components in all City pump stations. This approach uses a relative ranking and cannot be applied consistently if the set of pump stations being evaluated changes (as it did in this AMP Update compared to the 2015 AMP).

Pump Station Risk
Pump Station Likelihood
Component Risk
Component Likelihood Component Consequence
Pump Station Consequence

Page 829 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
4-2 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Figure 4-2. Risk Level Matrix (PUMP Update)
Consequence of Failure Rating
1 2 3 4 5 6 7 8 9 10
Likelihood of Failure Rating
1 2
3 4
5 6
7 8
9 10
Risk
Level Low MedLow Med MedHigh High
In summary, the changes from the 2015 AMP methodology included in this update are:
• Updated approach for calculating pump station likelihood of failure (details in Section 4.2.3.1).
• The likelihood of failure range for pump stations was 1-5 in the 2015 AMP. This has been changed to a range of 2-10 to align with the PUMP Update. • Revisions to the risk level matrix (Figure 4-2)
• Additional assets included in the assessment (several assets were added to the assessment from facilities in the 2015 AMP, to provide a more comprehensive assessment) For this update, the risk assessment was performed using the framework established in the PUMP Update and results of the 2022 condition assessment efforts. The database model used in 2015 was updated with any new assets or condition information.

Risk results were used to prioritize the rehabilitation, replacement, or maintenance actions to meet established service reliability and performance goals.

Page 830 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
4-3 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

4.2 Results
The results of the updated risk assessment are presented in the following sections by component and pump station. Appendix C also presents the risk results for each component, by pump station.

4.2.1 Component Risk Levels
Table 4-1 presents the total number of components that fall into each risk level category. The majority of pump station components are Medium-Low risk (43-percent of all assets). The risk results from the 2015 study are not shown because the updated risk results are not directly comparable due to the changes noted earlier.

Table 4-1. Summary of Component Risk Assessment Results Risk Level No. of Components(a) Percent of Total
Low 151 14%
Medium-Low 452 43%
Medium 326 31%
Medium-High 106 10%
High 15 1%
Total 1,050 100%
(a) RSZ4 (2023) was excluded from the total number of components to not duplicate entries from RSZ4

4.2.2 Component Risk Levels by Pump Station
Figure 4-3 shows the percentage of components in each facility that fall within each risk level (colored bars). The presentation of this risk distribution within each pump station provides a helpful comparison between pump stations.

Page 831 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
4-4 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Figure 4-3. Risk Levels of Assets, Percent of Total

4.2.3 Facility Risk Levels
The risk for each facility was evaluated based on the consequence of failure of the facility, as well as the combined likelihood scores of the components within each facility, as described below.

4.2.3.1 Facility Likelihood
The likelihood of failure for each facility was evaluated using the likelihood of failure scores of individual components within each pump station, weighted by their respective nominal monetary value.

An asset value weight was assigned to each component, as shown in Table 4-2.

Page 832 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
4-5 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 4-2. Component Value Weighting for Facility Likelihood Calculation Nominal Asset Value, dollars Weight
<$5,000 0.3
$5,000-$20,000 0.7
>$20,000 1.0
This value weighting considers that components of a higher value or importance (e.g., a pump) will have a greater impact on overall facility likelihood of failure than assets of lower value or importance (e.g., a field instrument or sump pump). Overall facility likelihood of failure scores were determined by first weighting the likelihood of failure scores of each individual component using the weighting factors shown in Table 4-2. The resulting weighted likelihood of failure scores for each component were then added together and divided by the sum of the weighting factors. This algorithm produces an overall likelihood of failure score between 2 and 10 for a given facility, in a manner similar to the likelihood of failure scoring for the individual components.

4.2.3.2 Facility Consequence
The consequence of failure of a given facility takes into account the impacts to the system should a that facility fail. Consequence of failure factors from the 2015 AMP were maintained and included: Community Disruption (evaluated by the type of customers in each Zone); and Service Reliability (evaluated based on the ability to meet demand scenarios in an outage/failure). Some consequence of failure scores changed from the 2015 AMP, but most remained the same as there were not significant changes to land use or system configuration/supply. Similar to the scoring for components, facility consequence of failure is rated on a 2 to 10 scale.

Page 833 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
4-6 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

4.2.3.3 Facility Risk Results
Table 4-3 presents the likelihood of failure, consequence of failure, and risk level results for pump station facilities, ranked from highest to lowest risk level.

Table 4-3. Summary of Facility Risk Assessment Results
Likelihood Score
(2-10)
Consequence
Score
(2-10) Risk Score
Risk Level
(Priority) Facility

6.2 5 31 Medium Rancho Solano Golf Course

4.6 6 27.6 Medium Eastridge

3.8 7 26.6 Medium Goldridge Zone 2

5.2 5 26 Medium Rolling Hills

5.2 5 26 Medium Rancho Solano Raw Water

5.4 4 21.6 Medium Rancho Solano Zone 4

4.6 4 18.4 Medium Upper Mangels Zone 2

4.6 4 18.4 Medium Sanctuary Zone 3

4.6 4 18.4 Medium Sanctuary Zone 4

4.2 5 21 Med-Low Paradise Valley Zone 2

3.4 6 20.4 Med-Low Rancho Solano Zone 5
4 5 20 Med-Low Martin Hill Zone 2

3.6 4 14.4 Med-Low Rancho Solano Zone 3

4.7 3 14.1 Med-Low Southbrook #2

4.3 3 12.9 Med-Low Southbrook #1

4.1 2 8.2 Med-Low South Cordelia
2 4 8 Low Rancho Solano Zone 4 (2023)
(a) Rancho Solano Zone 4 (RSZ4) was rehabilitated in 2023, after publishing of an earlier draft of this report. In certain sections of this report, RSZ4 is presented as ‘RSZ4’, which is the facility pre-rehabilitation and/or as ‘RSZ4 (2023)’, which is the facility after rehabilitation.

Figure 4-4 presents the distribution of facilities graphically within the context of likelihood and consequence of failure scores. The combination of facility likelihood and consequence of failure scores determines the location of the facility within Figure 4-4, and the associated risk level. Detailed facility risk results are provided in Appendix D.

Page 834 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
4-7 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Figure 4-4. Facility Risk Levels

Page 835 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
5-1 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023

5.0 UPDATED ASSET MANAGEMENT PLAN RECOMMENDATIONS
This chapter provides recommended improvements based on the assessment results described in the preceding chapters. The action plan matrix developed in 2015 (see Figure 5-1) was used as a guide to identify maintenance, near-term rehabilitation/replacement, or long-term rehabilitation/replacement needs. The condition rating and remaining useful life are used to determine the asset’s physical mortality score; performance rating and maintenance frequency are used to determine the asset’s level of service score. Refer to the 2015 AMP for details on how these ratings are used to determine each score. The action plan for each asset is shown in Appendix C.

Figure 5-1. Action Plan Matrix
Assumptions considered in the development of the Action Plan recommendations include:
• Engineering judgment was employed in the interpretation of Figure 5-1, including but not limited to the pump performance testing and operational analysis presented in Section 2.2. • Components that require replacement of a small piece of the component (e.g., replacement of backup batteries in an MCC; replacement of pipe nipple connecting valve and piping, etc.), were recommended for Increased Maintenance / Operational Adjustments, and details are provided in Appendix C Recommended Improvements.

Page 836 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
5-2 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
• Costs were developed at Class 5 AACE level estimate. Unit costs were reviewed and updated from the 2015 values. Overhead amounts included:
— Construction and installation – 50 percent of material cost (same as 2015) — Administrative, legal, engineering, and construction management contingency of 35% was applied to both the material cost and construction/installation cost (was only applied to material cost in 2015).
— Overhead and profit contingency of 20 percent was applied to both the material cost and construction/installation cost (was only applied to material cost in 2015). — Contingency of 30 percent was applied to both the material cost and construction/installation cost (was only applied to material cost in 2015).

5.1 Recommended 10-Year Rehabilitation/Replacement Program Components that require rehabilitation or replacement were developed into improvement projects by pump station. These requirements consider the recommendations developed in Table 2-7 for replacement of pumps based on performance as well as the risk analysis completed in this section which addresses overall LOF and COF of various facility assets. Table 5-1 presents an optimized program for the next ten years based on the risk levels determined in Section 4 and the Action Plan presented above. The capital program is valued at approximately $8.3M representing approximately $3.0M in asset replacement and approximately $5.3M in rehabilitation.

Asset replacement and corrective action/rehabilitation for each facility are summarized in Table 5-2. Note the recommendations for Rancho Solano Zone 4 are based on the analysis herein, although the City has completed many improvements since the March 2023 failure.

Page 837 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 5-1. Recommended 10-Year Replacement and Rehabilitation Program Facility Name
Risk Level,
Score
Action Plan Recommendation
Total Rehab +
Replacement
Cost, dollars
Year
Replacement
Near-Term
Corrective
Action/Rehab
Long-Term
Corrective
Action/Rehab 2024 2025 2026 2027 2028 2029 2030 2031 2032 2033 2034 Rancho Solano Golf
Course
Medium, 31 $527,250 $0 $486,238 $1,013,488 $1,013,488
Eastridge Medium, 27.6 $118,492 $0 $620,305 $738,797 $738,797 Gold Ridge Zone 2 Medium, 26.6 $60,014 $0 $0 $60,014 $60,014 Rolling Hills Medium, 26 $638,323 $0 $291,571 $929,894 $929,894 Rancho Solano Raw
Water
Medium, 26 $26,973 $0 $106,930 $133,903 $133,903
Rancho Solano Zone 4 Medium, 21.6 $70,600 $22,200 $818,233 $911,033 $911,033 Upper Mangels Zone 2 Medium, 18.4 $93,425 $0 $529,655 $623,080 $623,080 Sanctuary Zone 4 Medium, 18.4 $132,454 $0 $473,935 $606,389 $606,389 Sanctuary Zone 3 Medium, 18.4 $723,653 $0 $12,484 $736,138 $736,138 Paradise Valley Zone 2 Med-Low, 21 $22,385 $0 $25,498 $47,883 $47,883 Rancho Solano Zone 5 Med-Low, 20.4 $7,770 $0 $99,438 $107,208 $107,208 Martin Hill Zone 2 Med-Low, 20 $29,753 $0 $583,373 $613,126 $613,126 Rancho Solano Zone 3 Med-Low, 14.4 $185,000 $0 $83,250 $268,250 $268,250 Southbrook 2 Med-Low, 14.1 $103,568 $0 $553,035 $656,603 $656,603 Southbrook 1 Med-Low, 12.9 $139,120 $0 $540,755 $679,875 $679,875 South Cordelia Med-Low, 8.2 $101,750 $92,500 $0 $194,250 $194,250 Total $2,980,531 $114,700 $5,224,700 $8,319,931 $1,013,488 $798,811 $929,894 $1,044,936 $623,080 $606,389 $891,228 $881,376 $656,603 $679,875 $194,250

Page 838 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
5-4 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 5-2. Recommended Rehab/Replacement Program Details Facility Name
Action Plan Recommendation – Asset Details
Replacement
Near-Term
Corrective
Action/Rehab Long-Term Corrective Action/Rehab
Rancho Solano
Golf Course
• Controller
• System Service Panel
• Motor Control Center
• Lighting Panel
• Level Element (x2)
-
• Convenience Receptacles
• Motor Control Center (x2)
• Bladder Tank
• Pressure Relief Valve
• Check Valve (x3)
• Isolation Valve (x4)
Eastridge • Controller
• Surge Protector
• Flow Meter
• Pressure Element
• SCADA - OIT
-
• Air Compressor and control
panel
• MCC
• Convenience Receptacles
• Alarm System
Gold Ridge Zone 2 • Controller
• Pressure Element (x2)
• Lighting
-
Rolling Hills • Controller
• Motor Control Center
• Flow Element
• Pressure Element (x2)
• Lighting (x3)
• Seals
• Pump Control Valve
• Air Valve
-
• Lighting Panel
• Convenience Receptacles
• General Electrical
• Adaptor for Portable Unit
• Alarm System
• Valve
• Isolation Valve (x7)
• Air Valve
• Flow Meter Isolation Valve
Rancho Solano
Raw Water
• Lighting
-
• Lighting Panel
• Convenience Receptacles
• Air Valve
• Check Valve (x4)
• Isolation Valve (x4)
Rancho Solano
Zone 4
• Flow Element
• Pressure Element
• Pumps (x2)
Lighting • Controller
• Motor Control Center
• Lighting Panel
• Convenience Receptacles
• General Electrical
• Adaptor for Portable Unit
• SCADA - OIT
• Isolation Valve (x6)
• Air Valve (x2)

Page 839 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
5-5 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 5-2. Recommended Rehab/Replacement Program Details Facility Name
Action Plan Recommendation – Asset Details
Replacement
Near-Term
Corrective
Action/Rehab Long-Term Corrective Action/Rehab
Upper Mangels
Zone 2
• Controller
• Coupling (x2)
• Pumps (x2) or install
pump control (VFD or
pressure controls)
- • Motor Control Center
• Lighting Panel
• Convenience Receptacles
• Adaptor for Portable Unit
• Alarm System
• Air Valve (x2)
Sanctuary Zone 3 • Controller
• Motor Control Center
• SCADA – OIT
• Pumps (3)
-
• Air Compressor
• Coupling (x9)
• Surge Protector
• Convenience Receptacles
Sanctuary Zone 4 • Controller
• Coupling
• Pressure Element (x2)
• Lighting
• SCADA – OIT
-
• Air Compressor
• Coupling (x6)
• Motor Control Center
• Surge Protector
• Convenience Receptacles
Paradise Valley
Zone 2
• Controller
• Pressure Element
-
• Coupling (x3)
• Lighting Panel
• Convenience Receptacles
• Adaptor for Portable Unit
Rancho Solano
Zone 5
• Pressure Element (x2)
-
• Reducer
• Generator
Valve
Martin Hill Zone 2 • Controller
• Coupling (x3)
• Pressure Element
• Seals
-
• Motor Control Center
• Lighting Panel
• Alarm System
• Pressure Relief Valve
• Pump Control Valve (x3)
Rancho Solano
Zone 3
• Motor Control Center
-
• SCADA - OIT
Southbrook 2 • Controller
• Coupling (x3)
• SCADA - OIT
-
• Air Compressor and control
panel
• Coupling (x5)
• Motor Control Center
• Surge Protector
• Convenience Receptacles
• Alarm systems
Southbrook 1 • Controller - • Motor Control Center

Page 840 of 1105 ends

Potable Water Pump Station
Asset Management Plan Update
N-268-40-22-15-WP-R – AMP Addendum
5-6 City of Fairfield
Potable Water Pump Station – AMP Update
November 2023
Table 5-2. Recommended Rehab/Replacement Program Details Facility Name
Action Plan Recommendation – Asset Details
Replacement
Near-Term
Corrective
Action/Rehab Long-Term Corrective Action/Rehab
• Pressure Element (x2)
• Lighting
• SCADA - OIT
• Surge Protector
• Convenience Receptacles
• General Electrical
South Cordelia • Controller
• SCADA - OIT
• Lighting -

5.2 Recommended Next Steps
The City has proactively implemented the recommendations from the 2015 AMP and will further build upon that progress as they implement recommendations from this update. The following recommendations will allow the City to continue to use this AMP to guide future asset management of the pump stations:
• Complete the evaluation of Rancho Solano 4 pump station catastrophic failure in March 2023 and incorporate these recommendations into its capital rehabilitation planning. • Budget for and implement the replacement and rehabilitation recommendations outlined in this report and summarized in Table 5-1.
• Continue to track condition and performance of assets to develop trends, which will allow the City to make informed maintenance and asset management decisions. • Conduct future updates of the AMP similar to the process undertaken in 2022/2023.

Page 841 of 1105 ends

Pump Performance Testing Results
A1: Pump Efficiency Field Data
A2: Pump Curves
A3: Pump and System Curves

Appendix A

Page 842 of 1105 ends

Measured Flow
(gpm)
Measured TDH
(ft) Nameplate GPM Nameplate TDH Voltage (V) Amps
Reported Motor
Efficiency
Reported Overall
Efficiency Power Factor
Calculated Pump
Efficiency
Nameplate
Horsepower
Calculated Motor
Horsepower Input
Calculated Motor
kW Input
Calculated Motor
Horsepower
Output
(should equal
pump brake HP)
Calculated Pump
Efficiency from
Motor Output
Service Zone Pump Key-in from PDF Key-in from PDF Photos/City Photos/City Average from Spreadsheet
Average from
Spreadsheet
Key-in from
Spreadsheet Key-in from PDF Key-in from Spreadsheet
(Reported Overall
Efficiency) /
(Reported Motor
Efficiency)
Key-in from PDF
Amps * V * sq
rt(3) / 0.7457 /
1000 * PF
HP * 0.7457
Calculated Motor
Horsepower Input
* Reported Motor
Efficiency
gpm * TDH / 3960
/ Calculated
Motor
Horsepower
Output
(Ideal range: 0.7-

0.85, should not
be over 1)
ZONE 1
South Cordelia P1 1901 25 1900 42.5 484.3 32.00 0.93 0.44 0.77 0.47 30.00 27.72 20.67 25.78 0.47 South Cordelia P2 1957 23 1900 42.5 480.3 33.00 0.94 0.38 0.80 0.41 30.00 29.45 21.96 27.57 0.41 South Cordelia P3 1972 23 1900 42.5 480.7 32.33 0.94 0.40 0.78 0.43 30.00 28.15 20.99 26.35 0.43 ZONE 2
Gold Ridge P1 960 95 1000 100 482.7 39.70 0.93 0.68 0.75 0.73 40.00 33.38 24.89 31.04 0.74 Gold Ridge P2 942 95 1000 100 484.3 40.20 0.93 0.67 0.75 0.72 40.00 33.92 25.29 31.54 0.72 Gold Ridge P3 914 95 1000 100 482.7 39.30 0.93 0.67 0.74 0.72 40.00 32.60 24.31 30.32 0.72 Gold Ridge P4 1373 104 1385 110 481.3 59.47 0.95 0.65 0.84 0.69 50.00 55.85 41.64 52.77 0.68 Mangels P1 295 150 360 137 485.0 18.33 0.89 0.67 0.79 0.75 20.00 16.31 12.16 14.49 0.77 Mangels P2 292 148 360 137 490.7 19.00 0.89 0.66 0.77 0.74 20.00 16.67 12.43 14.81 0.74 Martin Hill P1 1121 129 1400 114.6 483.0 52.33 0.95 0.40 0.87 0.42 50.00 51.08 38.09 48.27 0.76 Martin Hill P2 1140 141 1400 114.6 480.7 53.33 0.95 0.78 0.87 0.83 50.00 51.80 38.63 48.95 0.83 Martin Hill P3 1066 139 1400 114.6 479.3 51.33 0.95 0.75 0.87 0.79 50.00 49.72 37.08 46.99 0.80 Paradise Valley P1 739 123 1400 106 494.0 51.03 0.91 0.59 0.66 0.65 50.00 38.65 28.82 35.17 0.65 Paradise Valley P2 700 125 1400 106 493.7 51.17 0.91 0.57 0.66 0.63 50.00 38.72 28.88 35.24 0.63 Paradise Valley P3 804 127 1400 106 488.7 45.53 0.95 0.68 0.74 0.72 50.00 38.24 28.52 36.14 0.71 Rolling Hills P1 1010 129 1400 115 487.7 51.07 0.92 0.684 0.84 0.74 50.00 48.59 36.23 44.70 0.74 Rolling Hills P2 1048 129 1400 115 486.0 52.27 0.92 0.705 0.83 0.77 50.00 48.97 36.52 45.05 0.76 Rolling Hills P3 965 129 1400 115 484.7 51.03 0.93 0.684 0.80 0.74 50.00 45.96 34.27 42.74 0.74 Southbrook 1 P1 345 90 450 100 488.0 17.40 0.93 0.56 0.73 0.60 20.00 14.40 10.74 13.39 0.59 Southbrook 1 P2 360 97 450 100 485.3 17.70 0.93 0.61 0.72 0.66 20.00 14.37 10.71 13.36 0.66 Southbrook 1 P3 221 99 450 100 485.0 15.87 0.93 0.46 0.67 0.49 20.00 11.98 8.93 11.14 0.50 Southbrook 1 P4 872 116 1250 90 487.0 40.93 0.95 0.69 0.81 0.73 40.00 37.50 27.97 35.44 0.72 Southbrook 2 P1 328 99 450 105 486.0 17.50 0.93 0.56 0.78 0.60 20.00 15.41 11.49 14.33 0.57 Southbrook 2 P2 448 81 450 105 485.3 19.17 0.93 0.54 0.79 0.58 20.00 17.07 12.73 15.87 0.58 Southbrook 2 P3 412 81 450 105 484.7 19.27 0.93 0.51 0.78 0.55 20.00 16.92 12.62 15.73 0.54 Southbrook 2 P4 962 81 1250 100 483.7 46.53 0.95 0.45 0.83 0.48 40.00 43.39 32.36 41.00 0.48 ZONE 3
Eastridge P1 215 157 180 195 489.7 14.60 0.92 0.57 0.91 0.62 20.00 15.11 11.27 13.90 0.61 Eastridge P2 190 157 180 195 485.0 14.87 0.92 0.49 0.91 0.53 20.00 15.24 11.36 14.02 0.54 Eastridge P3 210 159 180 195 486.7 14.70 0.92 0.56 0.91 0.61 20.00 15.12 11.28 13.91 0.61 Eastridge P4 1194 185 1250 195 484.7 87.00 0.95 0.71 0.80 0.74 100.00 78.35 58.43 74.75 0.75 Rancho Solano Zone 3 P1 530 240 705 245 483.3 48.63 0.94 0.61 0.97 0.65 60.00 52.96 39.49 49.84 0.64 Rancho Solano Zone 3 P2 525 226 705 245 482.0 52.40 0.94 0.57 0.89 0.61 60.00 52.21 38.93 49.13 0.61 Rancho Solano Zone 3 P3 555 231 705 245 479.3 52.63 0.94 0.62 0.89 0.66 60.00 52.15 38.89 49.08 0.66 Sanctuary Zone 3 P1 306 113 425 115 487.7 17.47 0.93 0.62 0.71 0.67 20.00 14.05 10.47 13.06 0.67 Sanctuary Zone 3 P2 211 88 425 115 485.3 16.27 0.93 0.38 0.67 0.41 20.00 12.29 9.16 11.43 0.41 Sanctuary Zone 3 P3 211 88 425 115 485.3 14.27 0.93 0.38 0.67 0.41 20.00 10.78 8.04 10.02 0.47 Sanctuary Zone 3 P4 786 129 1250 115 485.0 46.50 0.95 0.62 0.8 0.66 50.00 41.91 31.25 39.60 0.65 ZONE 4
Rancho Solano Zone 4 P1 184 194 257 208.3 33.50 0.91 0.61 0.90 0.67 15.00 14.59 10.88 13.28 0.68 Rancho Solano Zone 4 P2 249 194 257 207.7 38.83 0.91 0.71 0.91 0.78 15.00 17.05 12.71 15.51 0.79 Sanctuary Zone 4 P1 671 147 270 135 483.0 146.37 0.87 0.6 0.8 0.69 15.00 131.36 97.96 114.68 0.22 Sanctuary Zone 4 P2 236 132 270 135 489.0 13.07 0.92 0.6 0.88 0.65 15.00 13.06 9.74 12.02 0.65 Sanctuary Zone 4 P3 671 148 1250 124 483.0 46.37 0.95 0.6 0.8 0.63 50.00 41.61 31.03 39.33 0.64 ZONE 5
Rancho Solano Zone 5 P1 75 116 53.27 180 159.3 13.83 0.83 0.53 0.81 0.64 5.00 4.15 3.09 3.44 0.64 Rancho Solano Zone 5 P2 65 132 53.27 180 159.3 13.87 0.83 0.52 0.81 0.63 5.00 4.16 3.10 3.45 0.63

Page 843 of 1105 ends

Rancho Solano Zone 5 P3 65 136 53.27 180 159.3 14.07 0.83 0.54 0.81 0.65 5.00 4.22 3.14 3.50 0.64

OTHER PUMP STATIONS
Rancho Solano Golf Course P1 1446 270 1300 145 483.3 136.67 0.93 0.67 0.98 0.72 125.00 150.36 112.12 139.83 0.71 Rancho Solano Golf Course P2 1300 309 750 481.0 132.00 0.93 0.71 0.97 0.76 125.00 143.05 106.67 133.04 0.76 Rancho Solano Golf Course P3 679 316 500 481.7 78.00 0.91 0.65 0.95 0.72 60.00 82.90 61.82 75.03 0.72 Rancho Solano Raw Water P1 424 153 600 176 480.7 31.70 0.90 0.57 0.82 0.63 40.00 29.02 21.64 26.21 0.63 Rancho Solano Raw Water P2 525 155 600 176 483.7 34.07 0.90 0.65 0.83 0.72 40.00 31.77 23.69 28.53 0.72 Rancho Solano Raw Water P3 449 153 600 176 484.0 27.73 0.90 0.71 0.79 0.79 40.00 24.63 18.37 22.12 0.78 Rancho Solano Raw Water P4 190 153 200 158 484.3 13.80 0.90 0.65 0.72 0.73 15.00 11.18 8.34 10.00 0.73

Page 844 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\01_SCPS Pump Curves.dwg 10/6/2022 9:21 AMtnewman City of Fairfield South Cordelia Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
2015 Pump 1 Actual Operation LEGEND 2015 Pumps 2 and 3 Actual Operation Pumps 1, 2 and 3 Nameplate Curve 2022 Pump 1 Actual Operation 2022 Pump 2 Actual Operation 2022 Pump 3 Actual Operation
B

Page 845 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\02_GRPS Pump Curves.dwg 10/6/2022 10:41 AMtnewman 2015 Pump 1 Actual Operation LEGEND Notes: 1. Curve A is based on the nameplate duty point for Pumps 1-3 (1000 gpm @ 100' TDH, used in 2015) 2. Curve B is based on the nameplate impeller diameter for Pumps 1-3 (10.69"). 3. Pump 4 nameplate indicates 12.09" impeller diameter and duty point of 1385 gpm @ 110' TDH. Pump 4 has a different CAT# than Pumps 1-3. City has indicated the impeller has been trimmed. Additional pump curve may be needed.

City of Fairfield
Gold Ridge Pump Station
Pump Curve vs. Actual Operation
Appendix X
Pump Station Asset Management Plan Update
2015 Pump 2 Actual Operation
Pumps 1, 2 and 3 Nameplate Curve
2015 Pump 3 Actual Operation 2015 Pump 4 No Data 2022 Pump 3 Actual Operation 2022 Pump 4 Actual Operation 2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Curve A (see note 1)
Curve B (see note 2)
B

Page 846 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\03_MGPS Pump Curves.dwg 10/6/2022 9:22 AMtnewman 2015 Pump 1 Actual Operation LEGEND City of Fairfield Mangels Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
2015 Pump 2 Actual Operation
Pumps 1 and 2 Nameplate Curve
2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Notes: 1. Curve A is based on the nameplate duty point for Pumps 1-2 (360 gpm @ 137' TDH, used in 2015) and is consistent with nameplate impellar diameter (6.7") Curve A (see note 1)
B

Page 847 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\04_MHPS Pump Curves.dwg 10/6/2022 10:34 AMtnewman 2015 Pump 1 Actual Operation LEGEND City of Fairfield Martin Hill Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
2015 Pumps 2 and 3 Actual Operation
Pumps 1, 2 and 3 Nameplate Curve
2015 Pump 1 and 3 Retest 2015 Pump 2 Retest 2022 Pump 3 Actual Operation 2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Notes: 1. Curve A is based on the nameplate duty point for Pumps 1-3 (1400 gpm @ 114.6' TDH, used in 2015) and is consistent with nameplate impeller diameter (12.1") Curve A (see note 1)
B

Page 848 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\05_PVPS Pump Curves.dwg 10/14/2022 8:17 AMtnewman 2015 Pumps 1-3 Actual Operation LEGEND City of Fairfield Paradise Valley Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
Pumps 1, 2 and 3 Nameplate Curve
2022 Pump 3 Actual Operation2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Notes: 1. Curve A was used in 2015 analysis. 2. Curve B is based on the nameplate impeller diameter for Pumps 1-4 (11.6") and is consistent with nameplate duty point (1400 gpm @ 106' TDH).

Curve A (see note 1)
Curve B (see note 2)
B

Page 849 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\06_RHPS Pump Curves.dwg 10/6/2022 1:42 PMtnewman 2015 Pump 1 Actual Operation LEGEND City of Fairfield Rolling Hills Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
2015 Pump 2 Actual Operation
Pumps 1, 2 and 3 Nameplate Curve
2015 Pump 3 Actual Operation 2022 Pump 3 Actual Operation 2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Notes: 1. Curve A is based on the nameplate duty point for Pumps 1-3 (1400 gpm @ 115' TDH, used in 2015) and is consistent with nameplate impeller diameter (12.1") Curve A (see note 1)
B

Page 850 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\07_SBPS1 Pump Curves.dwg 10/6/2022 1:42 PMtnewman 2015 Pump 1 Actual Operation LEGEND City of Fairfield Appendix X Pump Station Asset Management Plan Update
2015 Pump 2 Actual Operation
Pumps 1, 2 and 3 Nameplate Curve
2015 Pump 3 Actual Operation 2022 Pump 3 Actual Operation 2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Southbrook 1 Pump Station Pump Curve vs. Actual Operation Notes: 1. Curve A is based on the nameplate duty point for Pumps 1-3 (450 gpm @ 100' TDH, used in 2015) and is consistent with nameplate impeller diameter (10.17") Curve A (see note 1)
B

Page 851 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\07_SBPS1 Pump Curves.dwg 10/6/2022 1:42 PMtnewman 2015 Pump 4 Actual Operation LEGEND City of Fairfield Southbrook 1 Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
Pump 4 Nameplate Curve
2022 Pump 4 Actual Operation Notes: 1. Curve A is based on the nameplate duty point for Pump 4 (1250 gpm @ 90' TDH, used in 2015) and is consistent with nameplate impeller diameter (11")
Curve A (see note 1)
B

Page 852 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\08_SBPS2 Pump Curves.dwg 10/6/2022 10:34 AMtnewman 2015 Pump 1 Actual Operation LEGEND City of Fairfield Appendix X Pump Station Asset Management Plan Update
2015 Pumps 2 and 3 Actual Operation
Pumps 1, 2 and 3 Nameplate Curve
2022 Pump 3 Actual Operation2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Southbrook 2 Pump Station Pump Curve vs. Actual Operation Notes: 1. Curve A is based on the nameplate duty point for Pumps 1-3 (450 gpm @ 105' TDH, used in 2015) and is consistent with nameplate impeller diameter (10.3")
Curve A (see note 1)
B

Page 853 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\08_SBPS2 Pump Curves.dwg 10/6/2022 10:34 AMtnewman 2015 Pump 4 Actual Operation LEGEND City of Fairfield Southbrook 2 Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
Pump 4 Nameplate Curve
2022 Pump 4 Actual Operation
Curve A (see note 1) Notes: 1. Curve A was used in 2015 analysis. 2. Curve B is based on the nameplate duty point for Pump 4 (1250 gpm @ 100' TDH). Curve B (see note 2) B

Page 854 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\09_ERPS Pump Curves.dwg 10/6/2022 1:17 PMtnewman City of Fairfield Eastridge Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
2015 Pump 1 Actual Operation LEGEND 2015 Pump 2 Actual Operation (Retest) Pumps 1, 2 and 3 Nameplate Curve2015 Pump 3 Actual Operation 2022 Pump 3 Actual Operation 2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Notes: 1. Curve A was used in the 2015 analysis. 2. Curve B is based on the nameplate duty point for Pumps 1-3 (180 gpm @ 195' TDH). Pumps 1-3 are 10-stage vertical turbine pumps; accordingly, measured TDH values should be divided by 10 in order to be plotted in this graph.

Curve A (see note 1)
2015 Measured Duty:Q = 156 gpm TDH = 208 ft 2015 Measured Duty: Q = 146 gpm TDH = 222.2 ft 2015 Measured Duty: Q = 146 gpm TDH = 192 ft 2015 Data Replotted (see note 2)
Curve B (see note 2)
B

Page 855 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\09_ERPS Pump Curves.dwg 10/6/2022 1:25 PMtnewman 2015 Pump 4 Actual Operation LEGEND City of Fairfield Appendix X Pump Station Asset Management Plan Update
Pump 4 Nameplate Curve
2022 Pump 4 Actual Operation
Eastridge Pump Station
Pump Curve vs. Actual Operation
Nameplate indicates this
pump model is 12JKH(3-stage) VTP. Nameplate
duty point is 1250 gpm @ 195' TDH.

B

Page 856 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\10_RSPS3 Pump Curves.dwg 10/5/2022 12:07 PMtnewman 2015 Pump 1 Actual Operation LEGEND City of Fairfield Rancho Solano 3 Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
2015 Pump 2 Actual Operation
Pumps 1, 2 and 3 Nameplate Curve
2015 Pump 3 Actual Operation 2022 Pump 3 Actual Operation 2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Curve A (see note 1) Notes: 1. Curve A was used in 2015 analysis. 2. Curve B is based on the nameplate duty point for Pump 4 (1250 gpm @ 100' TDH) and nameplate impeller diameter (8.3") Curve B (see note 2) B

Page 857 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\11_SANCPS3 Pump Curves.dwg 10/6/2022 2:15 PMtnewman City of Fairfield Appendix X Pump Station Asset Management Plan Update
Sanctuary 3 Pump Station
Pump Curve vs. Actual Operation
2015 Pump 1 Actual Operation LEGEND 2015 Pump 2 Actual Operation Pumps 1, 2 and 3 Nameplate Curve2015 Pump 3 Actual Operation 2022 Pump 3 Actual Operation 2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Curve A (see note 1) Notes: 1. Curve A was used in 2015 analysis and is consistent with the nameplate duty point for Pumps 1-3 (425 gpm @ 115' TDH) and nameplate impeller diameter (10.6")
B

Page 858 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\11_SANCPS3 Pump Curves.dwg 10/6/2022 2:15 PMtnewman City of Fairfield Sanctuary 3 Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
2015 Pump 4 Actual Operation LEGEND 2015 Pump 4 (Retest) Pump 4 Nameplate Curve 2022 Pump 4 Actual Operation Curve A (see note 1) Notes: 1. Curve A was used in 2015 analysis and is consistent with the nameplate duty point for Pump 4 (1250 gpm @ 115' TDH) and nameplate impeller diameter (11.8")
B

Page 859 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\12_RSPS4 Pump Curves.dwg 10/6/2022 2:44 PMtnewman 2015 Pump 1 Actual Operation LEGEND City of Fairfield Rancho Solano 4 Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
2015 Pump 2 Actual Operation
Pumps 1 and 2 Nameplate Curve
2022 Pump 1 Actual Operation2022 Pump 2 Actual Operation Curve A (see note 1) Notes: 1. Curve A was used in 2015 analysis and is consistent with nameplate impeller diameter for Pumps 1 and 2 (6.8"). 2. Nameplate data for Pumps 1 and 2 does not include duty point flow or TDH.

B

Page 860 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\13_SANCPS4 Pump Curves.dwg 10/6/2022 3:14 PMtnewman City of Fairfield Appendix X Pump Station Asset Management Plan Update
Sanctuary 4 Pump Station
Pump Curve vs. Actual Operation
2015 Pumps 1 and 2 Actual Operation LEGEND Pumps 1 and 2 Nameplate Curve 2022 Pump 1 Actual Operation 2022 Pump 2 Actual Operation
Curve A (see note 1) Notes: 1. Curve A was used in 2015 analysis and is consistent with Pumps 1 and 2 nameplate duty point (270 gpm @ 135' TDH) and nameplate impeller diameter (6.10"). 2. 2022 measured flow and TDH for Pump 1, as shown, do not fall near the pump curve.

B

Page 861 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\13_SANCPS4 Pump Curves.dwg 10/6/2022 3:14 PMtnewman City of Fairfield Sanctuary 4 Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
2015 Pump 3 Actual Operation LEGEND Pump 3 Nameplate Curve 2022 Pump 3 Actual Operation Curve A (see note 1) Notes: 1. Curve A was used in 2015 analysis and is consistent with Pump 3 nameplate duty point (1250 gpm @ 124' TDH) and nameplate impeller diameter (12.10").

B

Page 862 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\14_RSPS5 Pump Curves.dwg 10/6/2022 3:25 PMtnewman City of Fairfield Appendix X Pump Station Asset Management Plan Update
Rancho Solano 5 Pump Station
Pump Curve vs. Actual Operation
2015 Pump 1 Actual Operation LEGEND 2015 Pump 2 Actual Operation Pumps 1 and 2 Nameplate Curve 2015 Pump 1 Retest 2015 Pump 2 Retest 2022 Pump 1 Actual Operation 2022 Pump 2 Actual Operation Curve A (see note 1) Notes: 1. Curve A was used in 2015 analysis. 2. New Grundfos pumps were installed since 2015. Associated pump curves are needed for updating the analysis.

B

Page 863 of 1105 ends

N:\Clients\268 Fairfield\40-22-15 Fairfield PS AMP Update\CAD\Figures\14_RSPS5 Pump Curves.dwg 10/6/2022 3:25 PMtnewman City of Fairfield Rancho Solano 5 Pump Station Pump Curve vs. Actual Operation Appendix X Pump Station Asset Management Plan Update
2015 Pump 3 Actual Operation LEGEND 2015 Pump 3 Retest Pump 3 Nameplate Curve 2022 Pump 3 Actual Operation Curve A (see note 1) Notes: 1. Curve A was used in 2015 analysis. 2. New Grundfos pumps were installed since 2015. Associated pump curves are needed for updating the analysis.

B

Page 864 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 4/14/2023
0 50
100
150
200
250
300
0 80 160 240 320 400 480 560 640
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 1.A. Fairfield - Zone 4 System Curves: Rancho Solano 4 Pump Station (Pump 1) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 1 - Published Curve (Nameplate Flow/TDH Blank; BEP 80% at 310 gpm) Pump 1 - Measured Points
Pump 1 - Measured Curve (Fitted)
Maximum TDH Assumptions:
- Average Day Demand
- Pump Stations
> Rancho Solano 4 PS off
> Sanctuary 4 PS off
> Rancho Solano 3 PS off
> Sanctuary 3 PS off
- Reservoirs
> Rancho Solano 4 Res. at max level
> Rancho Solano 3 Res. at min level
Minimum TDH Assumptions:
- Peak Hour Demand
- Pump Stations
> Rancho Solano 4 PS off
> Sanctuary 4 PS off
> Rancho Solano 3 PS on
> Sanctuary 3 PS on
- Reservoirs
> Ranch Solano 4 Res. at min level
> Rancho Solano 3 Res. at max level
Test 3: Isolation valve wide
open, amperage running
outside service factor
Test 1: Pump throttled when assessor
arrived to facility (to avoid amperage
outside service factor of 1.15%)
Test 2

Page 865 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 4/14/2023
0 50
100
150
200
250
300
0 80 160 240 320 400 480 560 640
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 1.B. Fairfield - Zone 4 System Curves: Rancho Solano 4 Pump Station (Pump 2) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 2 - Published Curve (Nameplate Flow/TDH Blank; BEP 80% at 310 gpm) Pump 2 - Measured Points
Pump 2 - Measured Curve (Fitted)
Maximum TDH Assumptions:
- Average Day Demand
- Pump Stations
> Rancho Solano 4 PS off
> Sanctuary 4 PS off
> Rancho Solano 3 PS off
> Sanctuary 3 PS off
- Reservoirs
> Rancho Solano 4 Res. at max level
> Rancho Solano 3 Res. at min level
Minimum TDH Assumptions:
- Peak Hour Demand
- Pump Stations
> Rancho Solano 4 PS off
> Sanctuary 4 PS off
> Rancho Solano 3 PS on
> Sanctuary 3 PS on
- Reservoirs
> Ranch Solano 4 Res. at min level
> Rancho Solano 3 Res. at max level
Test 3: Isolation valve wide
open, amperage running
outside service factor Test 1: Pump throttled when assessor arrived to facility (to avoid amperage
outside service factor of 1.15%)
Test 2

Page 866 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 4/4/2023
0 40
80 120
160
200
240
0 200 400 600 800 1000 1200 1400 1600 1800
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 2.A. Fairfield - Zone 4 System Curves: Sanctuary 4 Pump Station (Pump 1) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 1 - Published Curve (Nameplate 270 gpm @ 135' TDH; BEP 77% @ 280 gpm) Pump 1 - Measured Points
Pump 1 - Measured Curve (Fitted)
Maximum TDH Assumptions:
- Average Day Demand
- Pump Stations
> Rancho Solano 4 PS off
> Sanctuary 4 PS off
> Rancho Solano 3 PS off
> Sanctuary 3 PS off
- Reservoirs
> Rancho Solano 4 Res. at max level
> Rancho Solano 3 Res. at min level
Minimum TDH Assumptions:
- Peak Hour Demand
- Pump Stations
> Rancho Solano 4 PS off
> Sanctuary 4 PS off
> Rancho Solano 3 PS on
> Sanctuary 3 PS on
- Reservoirs
> Ranch Solano 4 Res. at min level
> Rancho Solano 3 Res. at max level
BEP

Page 867 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 4/4/2023
0 40
80 120
160
200
240
0 200 400 600 800 1000 1200 1400 1600 1800
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 2.B. Fairfield - Zone 4 System Curves: Sanctuary 4 Pump Station (Pump 2) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 2 - Published Curve (Nameplate 270 gpm @ 135' TDH; BEP 77% @ 280 gpm) Pump 2 - Measured Points
Pump 2 - Measured Curve (Fitted)
Maximum TDH Assumptions:
- Average Day Demand
- Pump Stations
> Rancho Solano 4 PS off
> Sanctuary 4 PS off
> Rancho Solano 3 PS off
> Sanctuary 3 PS off
- Reservoirs
> Rancho Solano 4 Res. at max level
> Rancho Solano 3 Res. at min level
Minimum TDH Assumptions:
- Peak Hour Demand
- Pump Stations
> Rancho Solano 4 PS off
> Sanctuary 4 PS off
> Rancho Solano 3 PS on
> Sanctuary 3 PS on
- Reservoirs
> Ranch Solano 4 Res. at min level
> Rancho Solano 3 Res. at max level
BEP

Page 868 of 1105 ends

X-XXX-XX-XX-XX-X-XXXXX
Client Name
Project Title
Last Revised: xx-xx-xx
0 40
80 120
160
200
240
0 200 400 600 800 1000 1200 1400 1600 1800
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 2.C. Fairfield - Zone 4 System Curves: Sanctuary 4 Pump Station (Pump 3) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 3 - Published Curve (Nameplate 1250 gpm @ 124' TDH; BEP 86% at 1200 gpm) Pump 3 - Measured Points
Pump 3 - Measured Curve (Fitted)
Maximum TDH Assumptions:
- Average Day Demand
- Pump Stations
> Rancho Solano 4 PS off
> Sanctuary 4 PS off
> Rancho Solano 3 PS off
> Sanctuary 3 PS off
- Reservoirs
> Rancho Solano 4 Res. at max level
> Rancho Solano 3 Res. at min level
Minimum TDH Assumptions:
- Peak Hour Demand
- Pump Stations
> Rancho Solano 4 PS off
> Sanctuary 4 PS off
> Rancho Solano 3 PS on
> Sanctuary 3 PS on
- Reservoirs
> Ranch Solano 4 Res. at min level
> Rancho Solano 3 Res. at max level
BEP

Page 869 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 4/5/2023
0 40
80 120
160
200
240
0 200 400 600 800 1000 1200 1400 1600 1800
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 3.A. Fairfield - Zone 3B System Curves: Sanctuary 3 Pump Station (Pump 1) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 1 - Published Curve (Nameplate 425 gpm @ 115' TDH; BEP 77% at 450 gpm) Pump 1 - Measured Points
Pump 1 - Measured Curve (Fitted)
BEP

Page 870 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 4/5/2023
0 40
80 120
160
200
240
0 200 400 600 800 1000 1200 1400 1600 1800
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 3.B. Fairfield - Zone 3B System Curves: Sanctuary 3 Pump Station (Pump 2) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 2 - Published Curve (Nameplate 425 gpm @ 115' TDH; BEP 77% at 450 gpm) Pump 2 - Measured Points
Pump 2 - Measured Curve (Fitted)
BEP

Page 871 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 4/5/2023
0 40
80 120
160
200
240
0 200 400 600 800 1000 1200 1400 1600 1800
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 3.C. Fairfield - Zone 3B System Curves: Sanctuary 3 Pump Station (Pump 3) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 3 - Published Curve (Nameplate 425 gpm @ 115' TDH; BEP 77% at 450 gpm) Pump 3 - Measured Points
Pump 3 - Measured Curve (Fitted)
BEP

Page 872 of 1105 ends

X-XXX-XX-XX-XX-X-XXXXX
Client Name
Project Title
Last Revised: xx-xx-xx
0 40
80 120
160
200
240
0 200 400 600 800 1000 1200 1400 1600 1800
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 3.D. Fairfield - Zone 3B System Curves: Sanctuary 3 Pump Station (Pump 4) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 4 - Published Curve (Nameplate 1250 gpm @ 115' TDH; BEP 86% at 1150 gpm) Pump 4 - Measured Points
Pump 4 - Measured Curve (Fitted)
BEP

Page 873 of 1105 ends

X-XXX-XX-XX-XX-X-XXXXX
Client Name
Project Title
Last Revised: xx-xx-xx
0 50
100
150
200
250
300
350
400
450
500
0 200 400 600 800 1000 1200 1400
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 4.A. Fairfield - Zone 3B System Curves: Rancho Solano 3 Pump Station (Pump 1) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 1 - Published Curve (Nameplate 705 gpm @ 245' TDH; BEP 79% at 800 gpm) Pump 1 - Measured Points
Pump 1 - Measured Curve (Fitted)
BEP

Page 874 of 1105 ends

X-XXX-XX-XX-XX-X-XXXXX
Client Name
Project Title
Last Revised: xx-xx-xx
0 50
100
150
200
250
300
350
400
450
500
0 200 400 600 800 1000 1200 1400
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 4.B. Fairfield - Zone 3B System Curves: Rancho Solano 3 Pump Station (Pump 2) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 2 - Published Curve (Nameplate 705 gpm @ 245' TDH; BEP 79% at 800 gpm) Pump 2 - Measured Points
Pump 2 - Measured Curve (Fitted)
BEP

Page 875 of 1105 ends

X-XXX-XX-XX-XX-X-XXXXX
Client Name
Project Title
Last Revised: xx-xx-xx
0 50
100
150
200
250
300
350
400
450
500
0 200 400 600 800 1000 1200 1400
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 4.C. Fairfield - Zone 3B System Curves: Rancho Solano 3 Pump Station (Pump 3) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 3 - Published Curve (Nameplate 705 gpm @ 245' TDH; BEP 79% at 800 gpm) Pump 3 - Measured Points
Pump 3 - Measured Curve (Fitted)
BEP

Page 876 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 50
100
150
200
250
300
0 100 200 300 400 500 600 700
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 5.A. Fairfield - Zone 2C System Curves: Mangels Pump Station (Pump 1) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 1 - Published Curve (Nameplate 360 gpm @ 137' TDH; BEP 76% at 300 gpm) Pump 1 - Measured Points
Pump 1 - Measured Curve (Fitted)
BEP

Page 877 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 50
100
150
200
250
300
0 100 200 300 400 500 600 700
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 5.B. Fairfield - Zone 2C System Curves: Mangels Pump Station (Pump 2) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 2 - Published Curve (Nameplate 360 gpm @ 137' TDH; BEP 76% at 300 gpm) Pump 2 - Measured Points
Pump 2 - Measured Curve (Fitted)
BEP

Page 878 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 40
80 120
160
200
240
280
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 6.A. Fairfield - Zone 2D System Curves: Rolling Hills Pump Station (Pump 1) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 1 - Published Curve (Nameplate Flow/TDH Blank; BEP 86% at 1200 gpm) Pump 1 - Measured Points
Pump 1 - Measured Curve (Fitted)
BEP

Page 879 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 40
80 120
160
200
240
280
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 6.B. Fairfield - Zone 2D System Curves: Rolling Hills Pump Station (Pump 2) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 2 - Published Curve (Nameplate 1400 gpm @ 115' TDH; BEP 86% at 1200 gpm) Pump 2 - Measured Points
Pump 2 - Measured Curve (Fitted)
BEP

Page 880 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 40
80 120
160
200
240
280
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 6.C. Fairfield - Zone 2D System Curves: Rolling Hills Pump Station (Pump 3) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 3 - Published Curve (Nameplate 1400 gpm @ 115' TDH; BEP 86% at 1200 gpm) Pump 3 - Measured Points
Pump 3 - Measured Curve (Fitted)
BEP

Page 881 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 40
80 120
160
200
240
280
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 7.A. Fairfield - Zone 2D System Curves: Martin Hill Pump Station (Pump 1) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 1 - Published Curve (Nameplate 1400 gpm @ 114.6' TDH; BEP 86% at 1200 gpm) Pump 1 - Measured Points
Pump 1 - Measured Curve (Fitted)
BEP

Page 882 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 40
80 120
160
200
240
280
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 7.B. Fairfield - Zone 2D System Curves: Martin Hill Pump Station (Pump 2) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 2 - Published Curve (Nameplate 1400 gpm @ 114.6' TDH; BEP 86% at 1200 gpm) Pump 2 - Measured Points
Pump 2 - Measured Curve (Fitted)
BEP

Page 883 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 40
80 120
160
200
240
280
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 7.C. Fairfield - Zone 2D System Curves: Martin Hill Pump Station (Pump 3) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 3 - Published Curve (Nameplate 1400 gpm @ 114.6' TDH; BEP 86% at 1200 gpm) Pump 3 - Measured Points
Pump 3 - Measured Curve (Fitted)
BEP

Page 884 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 40
80 120
160
200
240
280
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 8.A. Fairfield - Zone 2D System Curves: Paradise Valley Pump Station (Pump 1) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 1 - Published Curve (Nameplate 1400 gpm @ 106' TDH; BEP 86% at 1150 gpm) Pump 1 - Measured Points
Pump 1 - Measured Curve (Fitted)
BEP

Page 885 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 40
80 120
160
200
240
280
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 8.B. Fairfield - Zone 2D System Curves: Paradise Valley Pump Station (Pump 2) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 2 - Published Curve (Nameplate 1400 gpm @ 106' TDH; BEP 86% at 1150 gpm) Pump 2 - Measured Points
Pump 2 - Measured Curve (Fitted)
BEP

Page 886 of 1105 ends

Fairfield System Curves-tn.xlsm
City of Fairfield
Pump Station AMP Update
Last Revised: 3/23/2023
0 40
80 120
160
200
240
280
0 200 400 600 800 1000 1200 1400 1600 1800 2000
Total Dynamic Head (TDH), feet
Flow, gpm
Figure 8.C. Fairfield - Zone 2D System Curves: Paradise Valley Pump Station (Pump 3) Maximum TDH System Curve (Modeled)
Minimum TDH System Curve (Modeled)
Pump 3 - Published Curve (Nameplate 1400 gpm @ 106' TDH; BEP 86% at 1150 gpm) Pump 3 - Measured Points
Pump 3 - Measured Curve (Fitted)
BEP

Page 887 of 1105 ends

Materials Testing Results

Appendix B

Page 888 of 1105 ends

Condition Assessment of Rancho Solano
Golf Course and Raw Water Pump
Stations
City of Fairfield
Prepared for: Mike Zacharia, PE
Principal Engineer
West Yost
2020 Research Park Drive, Suite 100
Davis, CA 95833
Date: August 3, 2022
Prepared by:

V&A Project No. 22-0005

Page 889 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Table of Contents V&A Project No. 22-0005 i
Table of Contents
Table of Contents ..................................................................................................................................... i Tables ............................................................................................................................................... ii Figures .............................................................................................................................................. ii Abbreviations and Acronyms .................................................................................................................. iii 1 Introduction ...................................................................................................................................... 1 2 Approach........................................................................................................................................... 2

2.1 Visual Assessment ...................................................................................................................... 2

2.1.1 VANDA® Concrete Condition Index ..................................................................................... 3

2.1.2 VANDA® Metal Condition Index .......................................................................................... 4

2.2 Concrete Assessment Methods ................................................................................................... 5

2.2.1 Sounding ........................................................................................................................... 5

2.3 Metal Assessment Methods ........................................................................................................ 5

2.3.1 Ultrasonic Testing.............................................................................................................. 5

2.3.2 Dry Film Thickness ............................................................................................................ 6 3 Results.............................................................................................................................................. 7

3.1 Rancho Solano Golf Course Pump Station .................................................................................. 7

3.1.1 Visual Assessment............................................................................................................. 7

3.1.2 Ultrasonic Thickness Testing ............................................................................................. 9

3.1.3 Condition Summary .........................................................................................................11

3.1.4 Recommendations...........................................................................................................11

3.2 Rancho Solano Raw Water PS ...................................................................................................12

3.2.1 Visual Assessment...........................................................................................................12

3.2.2 Ultrasonic Thickness Testing ...........................................................................................13

3.2.3 Condition Summary .........................................................................................................14

3.2.4 Recommendations...........................................................................................................14 Appendix A UT Locations and Data ....................................................................................................... A-1

Page 890 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Table of Contents V&A Project No. 22-0005 ii
Tables
Table 2-1. VANDA® Concrete Condition Index............................................................................................................ 3 Table 2-2. VANDA® Metal Condition Index ................................................................................................................. 4 Table 3-1. Summary of Defects Observed at the Rancho Solano Golf Course Pump Station ................................ 9 Table 3-2. UT Summary Data for Rancho Solano Golf Course PS Piping ...............................................................10 Table 3-3. Rancho Solano Golf Course DFT Summary ............................................................................................11 Table 3-4. Rancho Solano Golf Course Pump Station Condition Summary ...........................................................11 Table 3-5. UT Summary Data for the Rancho Solano Raw Water Pump Station Piping........................................13 Table 3-6. Rancho Solano Raw Water Pump Station DFT Summary......................................................................13 Table 3-7. Raw Water Pump Station Condition Summary.......................................................................................14 Figures
Figure 1-1. General Location of the Rancho Solano Pump Stations ........................................................................ 1 Table 2-1. VANDA® Concrete Condition Index............................................................................................................ 3 Table 2-2. VANDA® Metal Condition Index ................................................................................................................. 4 Figure 2-1. Clock Positions on Pipe Looking Downstream........................................................................................ 5 Table 3-1. Summary of Defects Observed at the Rancho Solano Golf Course Pump Station ................................ 9 Table 3-2. UT Summary Data for Rancho Solano Golf Course PS Piping ...............................................................10 Table 3-3. Rancho Solano Golf Course DFT Summary ............................................................................................11 Table 3-4. Rancho Solano Golf Course Pump Station Condition Summary ...........................................................11 Table 3-5. UT Summary Data for the Rancho Solano Raw Water Pump Station Piping........................................13 Table 3-6. Rancho Solano Raw Water Pump Station DFT Summary......................................................................13 Table 3-7. Raw Water Pump Station Condition Summary.......................................................................................14

Page 891 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Abbreviations and Acronyms V&A Project No. 22-0005 iii
Abbreviations and
Acronyms
Abbreviations/Acronyms Definition
ACI.............................................American Concrete Institute AMPP.........................................Association for Materials Protection and Performance ANSI ..........................................American National Standards Institute ASTM.........................................American Society for Testing and Materials AWWA ........................................American Water Works Association AVG. ..........................................Average
DIP ............................................Ductile Iron Pipe DIRECT. .....................................Direction
FT. .............................................Feet
HSS ...........................................Hollow Structural Sections IN. .............................................Inch
MAX...........................................Maximum
MIN. ..........................................Minimum
NACE .........................................NACE is now Association for Materials Protection and Performance (AMPP)
DFT............................................Dry Film Thickness UT..............................................Ultrasonic Thickness N/A ...........................................Not applicable PSI ............................................Pounds per square inch PS ............................................. Pump Station V&A ...........................................V&A Consulting Engineers, Inc.

VANDA® .....................................V&A Condition Index WS.............................................Welded Steel WTP...........................................Water Treatment Plant

Page 892 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Introduction V&A Project No. 22-0005 1
1 Introduction
V&A Consulting Engineers (V&A) was retained by West Yost & Associates (West Yost) to perform a condition assessment of two water pump stations (PS) within Rancho Solano, in Fairfield, California.

Figure 1-1 shows an aerial map with the locations of the two pump stations.

The condition assessment is part of a follow-up study performed by West Yost in 2015. The Rancho Solano Golf Course (Golf Course PS) and Raw Water Pump Stations (Raw Water PS) were originally not owned by the City at the time of the study. Now that the City has taken over ownership of these facilities, the City is in need of establishing a baseline condition of the two pump stations.

The Raw Water Pump Station was constructed in 1988 and has undergone multiple rehabilitation of the pump system. The Golf Course Pump Station was constructed circa 1990.

Figure 1-1. General Location of the Rancho Solano Pump Stations

Page 893 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Approach V&A Project No. 22-0005 2
2 Approach

2.1 Visual Assessment
Qualitative visual evaluations were conducted from inside and outside of the pump stations, focusing on the condition of concrete surfaces and piping. Cracks, delamination, corrosion, and other concrete defects referenced in American Concrete Institute (ACI) 201.1R-92, “Guide for Making a Condition Survey of Concrete in Service” were documented with digital, still photographs. The condition of metal components and coatings were also evaluated and documented. Much of the visual assessment data is subjective and is based upon V&A’s extensive experience evaluating concrete and metallic structures in the water and wastewater industries. Standardized ratings used to characterize condition were assigned based on the VANDA Concrete and Metal Condition Indices, as shown in the subsequent sections.

Page 894 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Approach V&A Project No. 22-0005 3

2.1.1 VANDA® Concrete Condition Index
V&A created the VANDA Concrete Condition Index (Table 2-1) to provide consistent reporting of corrosion damage based on objective criteria. Concrete condition is rated from Level 1 to Level 5 based upon field observations and measurements, with Level 1 indicating the best case and Level 5 indicating severe damage. The individual criteria are applied based on engineering judgment to arrive at the overall rating.

Table 2-1. VANDA® Concrete Condition Index
Condition
Rating Description
Representative
Photograph
Level 1 Little or no damage to concrete
▪ Hardness............... hard surface
▪ Surface profile ...... smooth, apparently intact
▪ Cracks ................... hairline width, minimal frequency ▪ Spalling ................. none
▪ Reinforcement ...... not exposed or damaged
Level 2 Minor surface damage
▪ Hardness............... soft surface layer to 1/8-inch depth ▪ Surface profile ...... fine aggregate exposed
▪ Cracks ................... hairline width, moderate frequency ▪ Spalling ................. shallow spalling, minimal frequency ▪ Reinforcement ...... not exposed or damaged
Level 3 Moderate surface damage
▪ Hardness............... soft surface layer to 1/4-inch depth ▪ Surface profile ...... large aggregate exposed or protruding ▪ Cracks ................... up to 1/32-inch width, moderate frequency ▪ Spalling ................. shallow spalling, minimal frequency ▪ Reinforcement ...... exposed; minor damage, minimal frequency Level 4 Loss of concrete mortar and damage to reinforcement ▪ Hardness............... soft paste beyond 1/4-inch depth ▪ Surface profile ...... large aggregate exposed, loose, or missing ▪ Cracks ................... 1/8- to 1/4-inch width, moderate frequency ▪ Spalling ................. deep spalling, moderate frequency ▪ Reinforcement ...... exposed with damage, moderate frequency Level 5 Bulk loss of concrete and reinforcement
▪ Hardness............... soft paste beyond 1-inch depth ▪ Surface profile ...... large aggregate exposed, loose, or missing ▪ Cracks ................... over 1/2-inch width, or narrower and frequent ▪ Spalling ................. deep spalling, high frequency ▪ Reinforcement ...... consumed; loss of structural integrity © 2020 V&A Consulting Engineers, Inc. All rights reserved.

Page 895 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Approach V&A Project No. 22-0005 4

2.1.2 VANDA® Metal Condition Index
V&A created the VANDA Metal Condition Index (Table 2-2) to provide consistent reporting of corrosion damage based on objective criteria. Metal condition is rated from Level 1 to Level 5 based upon field observations and measurements, with Level 1 indicating the best case and Level 5 indicating severe damage. The individual criteria are applied based on engineering judgment to arrive at the overall rating.

Table 2-2. VANDA® Metal Condition Index
Condition
Rating Description
Representative
Photograph
Level 1 Little or no corrosion
▪ Wall thickness loss, general ......none
▪ Wall thickness loss, pitting.........none to minimal
▪ Extent (area) of corrosion...........may be widespread but superficial Level 2 Minor corrosion
▪ Wall thickness loss, general ......up to 20%
▪ Wall thickness loss, pitting.........up to 20%
▪ Extent (area) of corrosion...........localized
Level 3 Moderate corrosion
▪ Wall thickness loss, general ......20% to 40%
▪ Wall thickness loss, pitting.........20% to 60%
▪ Extent (area) of corrosion...........up to half of surface Level 4 Severe corrosion
▪ Wall thickness loss, general ......40% to 60%
▪ Wall thickness loss, pitting.........60% to 100% (pinholes) ▪ Extent (area) of corrosion...........most of surface
Level 5 Failure or imminent failure
▪ Wall thickness loss, general ......greater than 60%
▪ Wall thickness loss, pitting.........100% (holes)
▪ Extent (area) of corrosion...........most or all of surface © 2020 V&A Consulting Engineers, Inc. All rights reserved.

Page 896 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Approach V&A Project No. 22-0005 5

2.2 Concrete Assessment Methods

2.2.1 Sounding
Sounding was performed within the structures at the evaluator’s discretion to investigate for shallow, subsurface discontinuities. Using a hammer to strike accessible concrete surfaces, the sound can indicate if defects such as voids, delamination, or honeycombing are present. The sound returned from solid concrete without subsurface discontinuities is a sharp “ping” noise. A “hollow” sound generally means that a discontinuity exists beneath the sounding location. A soft “thud” typically results from deteriorated concrete.

2.3 Metal Assessment Methods

2.3.1 Ultrasonic Testing
Ultrasonic testing (UT) is a non-destructive evaluation technique used for the determination of metal wall thickness. High-frequency sound waves are transmitted through one side of a metal wall from a transducer. When the sound waves reach the other side of the metal wall, a fraction of the waves will echo back to the transducer. The metal thickness is determined by recording the time it takes for the sound wave to travel through the metal and return.

A-scan point measurements were performed for various metal structures and piping. For pipes, measurements were made around the pipe circumference and were referenced to clock positions (e.g., 12:00, 3:00, 6:00, or 9:00) viewed in the downstream direction (Figure 2-1).

If pitting or extremely localized corrosion is found, a pit depth gauge will be used since UT will not provide acceptable readings due to the rough surface.

Figure 2-1. Clock Positions on Pipe Looking
Downstream

To determine the amount of corrosion that has occurred from UT data, the original measured thickness of the pipe must be known. The thickness measurements recorded to assess corrosion can then be compared against the original thickness measurements. For this project, the original thickness of the piping, based on the measurements was unknown; so the original wall thickness was determined using the following procedure:

1. Group the thickness readings by the specified pipe for the process area, material, diameter, and service.
12:00
6:00
9:00 3:00
10:30 1:30
7:30 4:30
Downstream View
Pipe Cross Section
12:00
6:00
9:00 3:00
10:30 1:30
7:30 4:30
Downstream View
Pipe Cross Section Page 897 of 1105
Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Approach V&A Project No. 22-0005 6

2. Visually exclude outliers above the top of the core grouping of thickness measurements. These may be anomalous measurements that are slightly thicker than the typical original thickness of the pipe.

3. Assume that the consistent thickness readings that remain reflect the original thickness of the metal.
a. For steel pipes, the standard thickness from ANSI B36.10was used as the nominal thickness. b. For cast and ductile iron pipe, if the pipe was not marked with the class or specified in the contract documents, the nominal thickness that was assumed based on the nearest standard average thickness per ANSI/AWWA C150/A21.5. For grooved end pipe with couplings, the limitations of AWWA C115 (i.e., minimum Class 53) were also applied to the nominal thickness selection
The specific nominal thickness and tolerance selected for each test location are shown with the UT testing results. It should be noted that if the measured thicknesses are within the tolerances that were likely to have been applied during the manufacture of the piping, thickness measurements below nominal are not necessarily an indication of corrosion and may be considered minor corrosion.

To an extent, this method implies that the internal corrosion is non-uniform across the surfaces so that the difference between the maximum thickness measurements and the minimum thickness measurements is representative of corrosion rate due to pitting or otherwise localized corrosion.

2.3.2 Dry Film Thickness
Dry film thickness (DFT) is the thickness of a coating or lining after it has cured. A DFT gauge uses electromagnetic induction or eddy current technology to measure the thickness of a wide variety of coatings on metal surfaces. V&A used a gauge that can measure coatings up to 0.2 inches (2 00 mils) in thickness, and the gauge was calibrated using shims prior to the collection of data. Measurements were taken on metallic components in the same manner as described for ultrasonic testing in Section 2.3.1.

Page 898 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Abbreviations and Acronyms V&A Project No. 22-0005 7
3 Results

3.1 Rancho Solano Golf Course Pump Station

3.1.1 Visual Assessment
The Rancho Solano Golf Course pump station consists of a concrete masonry building, three pumps that feed water through a combined discharge pipe to two filtration units, and associated coated steel and ductile iron piping, valves, and controllers.

In general, the concrete surfaces of the pump station were in VANDA Level 1 condition. Sounding was performed on the station’s walls and floor. No signs of concrete spalling or delamination were observed during the assessment.

The metal components and piping were in VANDA Level 2 condition excluding the metal cabinet shown in Photo 3-2, which was in VANDA Level 4 condition. Table 3-1 presents a summary of observed defects at the pump station. The noted defects included:
▪ Minor corrosion of the pump discharge piping, see Photo 3-1; ▪ Severe surface corrosion on a metal cabinet and the metal platform beneath, see Photo 3-2. ▪ Surface corrosion on the bottom of the bladder tank in contact with the metal platform , see Photo 3-3.
▪ Surface corrosion of a ductile iron tee, see Photo 3-4. ▪ Surface corrosion on the bottom panel of the electrical cabinet and leg supports, see Photo 3-5 and Photo 3-6.
▪ The coating of the metal platform was generally in good condition except at locations in contact with mounted structures. This is likely attributed to dissimilar metals. ▪ Coating deterioration was observed on the supports of equipment as shown in Photo 3-1, Photo 3-2 and Photo 3-5.
▪ Water leakage was observed coming from the filtration unit shown in Photo 3-7. The water leaking from the unit may promote corrosion of surrounding metallic components.

Page 899 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Abbreviations and Acronyms V&A Project No. 22-0005 8
Photo 3-1. Corrosion staining on surface of pump
discharge piping.

Photo 3-2. Corrosion on bottom of metal cabinet
and metal platform.

Photo 3-3. Surface corrosion on bottom of
bladder tank.

Photo 3-4. Surface corrosion of ductile iron tee.

Photo 3-5. Corrosion on bottom panel of
electrical cabinet.

Photo 3-6. Coating damage and minor corrosion
on cabinet leg.

Page 900 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Abbreviations and Acronyms V&A Project No. 22-0005 9
Photo 3-7. Signs of water leakage from filtration
unit.

Photo 3-8. Pump station walls and roof in good
condition. No observed degradation.

Table 3-1. Summary of Defects Observed at the Rancho Solano Golf Course Pump Station Defect
ID Location Type
VANDA
Condition Remarks
1 Discharge
pipe
Corrosion staining Level 2 Surface corrosion along the discharge pipe.
2 Metal cabinet Sever Surface corrosion Level 4 Severe surface corrosion on cabinets legs and side panel.
3 Bladder tank Surface corrosion Level 2 Surface corrosion at metal platform connection.
4 Ductile iron
tee
Surface Corrosion Level 2 Surface corrosion on entire surface of joint.
5 Electrical
cabinet
Surface corrosion Level 2 Surface corrosion on entire panel base. 6 Electrical
cabinet
Coating damage and
corrosion
Level 2 Corrosion of electrical panel legs at
platform connection.
7 Metal cabinet Surface corrosion Level 2 Surface corrosion on platform.

3.1.2 Ultrasonic Thickness Testing
Ultrasonic thickness measurements were recorded on the accessible steel pipe on the main floor.

Measurements were recorded in bands along the circumference of the pipeline (4 circumferential readings per band) spaced at regular intervals. The thickness measurements and associated conclusions only apply to where the readings were taken. The nominal thickness of the piping is not known; therefore, an assumed nominal thickness, based on ANSI B36.10 for standard steel pipe and ANSI/AWWA C150/A21.5 for ductile iron were used to determine the metal loss.

UT measurements are summarized in Table 3-2. The maximum measured metal loss on the 66-inch pipe was 8%, which is considered minor solely based on metal loss. The metallic assets were classified as VANDA Level 2 condition.

Page 901 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Abbreviations and Acronyms V&A Project No. 22-0005 10
Table 3-2. UT Summary Data for Rancho Solano Golf Course PS Piping UT Band Size/Material
Minimum
Thickness
(inches)
Average
Thickness
(inches)
Maximum
Thickness
(inches)
Assumed
Nominal
Thickness
(inches)
Maximum
Metal Loss
(%)
1-3
12" steel w/
white coating 0.398 0.419 0.458 0.406 2%
4 6" steel w/
blue coating 0.249 0.259 0.263 0.280 11%
5 14" ductile iron
w/ black
coating

0.383 0.397 0.410 0.390 2%
6 14" ductile iron
w/ black
coating
(exterior)

0.355 0.389 0.417 0.390 9%
7 8" ductile iron
w/ white
coating
(exterior)

0.339 0.372 0.406 0.390 13%
8 12" welded
steel w/ gray
coating

0.358 0.361 0.363 0.375 5%
9 8" ductile iron
w/ black
coating

0.338 0.377 0.411 0.390 13%
*Assumed Nominal Pipe Thickness is based on standard schedules for seamless and welded carbon and alloy steel pipes per ANSI B36.10, and ductile iron pipe per ANSI/AWWA C150/A21.5.

3.1.2.1 Dry Film Thickness
Dry film thickness measurements were recorded on the coating of the Golf Course PS. Typically, a minimum coating thickness of eight mils is recommended for this coating per AWWA C218. The average DFT thickness exceeds the recommended DFT. Table 3-3 summarizes the DFT measurements.

Page 902 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Abbreviations and Acronyms V&A Project No. 22-0005 11
Table 3-3. Rancho Solano Golf Course DFT Summary
Location Pipe
Minimum
(mils)
Average
(mils)
Maximum
(mils)
Std.

Dev.
(mils)
Rancho Solano
Golf Course PS 12-inch welded steel w/ white coating 0.70 2.08 4.30 0.91 Rancho Solano
Golf Course PS 6-inch welded steel w/ blue coating 1.90 3.92 5.30 0.93 Rancho Solano
Golf Course PS 14-inch ductile iron w/ black coating 1.10 3.12 5.80 1.15 Rancho Solano
Golf Course PS
14-inch ductile iron w/black coating
(exterior) 0.80 2.52 4.50 1.20
Rancho Solano
Golf Course PS
8-inch ductile iron w/white coating
(exterior) 4.00 2.91 8.70 1.95
Rancho Solano
Golf Course PS 12-inch welded steel w/ gray coating 1.80 2.76 3.60 0.49 Rancho Solano
Golf Course PS 8-inch ductile iron w/ black coating 2.30 3.78 10.60 2.95

3.1.3 Condition Summary
Table 3-4 summarizes the overall condition of the Rancho Solano Golf Course Pump Stations.

Table 3-4. Rancho Solano Golf Course Pump Station Condition Summary Building Structure/Equipment
VANDA
Condition Remarks
Rancho Solano Golf
Course PS
Concrete masonry unit
walls
Level 1 Minor self-healed cracks, no signs of
delamination.

Concrete floor and pipe
pedestals
Level 1 Minor self-healed cracks, no signs of
delamination.

Metal components and
piping
Level 2 Surface corrosion on piping, metal
cabinets and metal platform. Metal
thickness measurements indicate
minor corrosion of piping.

3.1.4 Recommendations
Based on the results of the condition assessment, V&A presents the following recommendations for West Yost and the City of Fairfield to consider.
▪ Within 2 years, perform touch-up coating repairs on the metallic components presenting surface corrosion.
▪ Replacement of the metal cabinet.

Page 903 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Abbreviations and Acronyms V&A Project No. 22-0005 12

3.2 Rancho Solano Raw Water PS

3.2.1 Visual Assessment
The Rancho Solano Raw Water PS consists of a concrete masonry building, four pumps that feed into a combined discharge pipe, associated coated steel, as well as valves, and controllers.

In general, the concrete surfaces and metal piping were in VANDA Level 1 condition. The discharge pump, piping, and platform had recently been recoated. The coating was in good condition on the interior and exterior piping, as seen in Photo 3-9 and Photo 3-10. The electrical cabinet and metal platform were in good condition with no observed defects; see Photo 3-11. The concrete masonry walls and concrete floors were in good condition; see Photo 3-12. Sounding was performed on the station walls and floor. No signs of concrete spalling or delamination were observed during the assessment.

Photo 3-9. Pumps and effluent pipe in good
condition; recently coated.

Photo 3-10. Effluent pipe outside in good
condition.

Photo 3-11. Electrical cabinet in good condition;
Metal platform in good condition.

Photo 3-12. Pump station walls in good
condition; no degradation of brick or concrete.

Page 904 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Abbreviations and Acronyms V&A Project No. 22-0005 13

3.2.2 Ultrasonic Thickness Testing
Ultrasonic thickness measurements were recorded on the accessible steel pipe on the main floor.

Measurements were recorded in bands along the circumference of the pipeline (four circumferential readings per band) spaced at regular intervals. The thickness measurements and associated conclusions only apply to where the readings were taken. The nominal thickness of the piping is not known; therefore, an assumed nominal thickness, based on ANSI B36.10 for standard steel was used to determine the metal loss.

Ultrasonic thickness measurements are summarized in Table 3-5. The maximum measured metal loss on the 66-inch pipe was 5%, which is considered minor solely based on metal loss. The metallic assets were classified as VANDA Level 2 condition.

Table 3-5. UT Summary Data for the Rancho Solano Raw Water Pump Station Piping Location
UT
Band
Size/Material
Minimum
Thickness
(inches)
Average
Thickness
(inches)
Maximum
Thickness
(inches)
Assumed
Nominal
Thickness
(inches)
Maximum
Metal Loss
(%)
Rancho Solano
Raw Water PS 1-3
10" steel w/
green
coating

0.365 0.379 0.393 0.360 0%
Rancho Solano
Raw Water PS 4-5
14" steel w/
green
coating
(exterior)

0.357 0.393 0.417 0.375 5%
*Assumed Nominal Pipe Thickness is based on standard schedules for seamless and welded carbon and alloy steel pipes per ANSI B36.10, and ductile iron pipe per ANSI/AWWA C150/A21.5.

3.2.2.1 Dry Film Thickness
Dry film thickness measurements were recorded on the coating of the Raw Water PS piping. Typically, a minimum coating thickness of eight mils is recommended for this coating per AWWA C218. The average DFT thickness exceeds the recommended DFT. Table 3-3 summarizes the DFT measurements.

Table 3-6. Rancho Solano Raw Water Pump Station DFT Summary Location Pipe
Minimum
(mils)
Average
(mils)
Maximum
(mils)
Std.

Dev.
(mils)
Rancho Solano Raw
Water PS 10-in welded steel w/ green coating 5.60 10.43 15.70 2.31 Rancho Solano Raw
Water PS
14 -in welded teel w/ green coating
(exterior) 5.90 9.03 12.50 1.61

Page 905 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Abbreviations and Acronyms V&A Project No. 22-0005 14

3.2.3 Condition Summary
Table 3-4 summarizes the overall condition of the Rancho Solano Pump Stations.

Table 3-7. Raw Water Pump Station Condition Summary
Building Structure/Equipment
VANDA
Condition Remarks
Rancho Solano Raw
Water PS
Concrete masonry unit
walls
Level 2 Minor self-healed cracks, no signs of
delamination.

Concrete floor Level 1 Minor self-healed cracks, no signs of delamination.

Metal components and
piping.

Level 1 Metal components had been recently
coated; in good condition.

3.2.4 Recommendations
▪ In 5 – 10 years, reassess the pump station.

Page 906 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Appendix A UT Locations and Data
V&A Project No. 22-0005 A-1
Appendix A
UT Locations and Data

Page 907 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Appendix A UT Locations and Data
V&A Project No. 22-0005 A-2
Photo A--1. UT band locations 1-5 for the Golf Course PS.

Photo A--2. UT band location 6 for the Golf Course PS.

Page 908 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Appendix A UT Locations and Data
V&A Project No. 22-0005 A-3
Photo A--3. UT Band location 7 for the Golf Course PS.

Photo A--4. UT Band location 8 for the Golf Course PS.

Page 909 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Appendix A UT Locations and Data
V&A Project No. 22-0005 A-4
Photo A--5. UT band location 9 for the Golf Course PS
.

Photo A--6. UT band locations 1-2 for the Raw Water PS

Page 910 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Appendix A UT Locations and Data
V&A Project No. 22-0005 A-5
2 Photo A-7. UT band location 3 for Raw Water PS
Photo A--8. UT band location 4 for the Raw Water PS

Page 911 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Appendix A UT Locations and Data
V&A Project No. 22-0005 A-6
Photo A--9 UT band 5 for the Raw Water PS

Page 912 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Appendix A UT Locations and Data
V&A Project No. 22-0005 A-7
Table A-1. Rancho Solano Golf Course Pump Station Raw UT Data Band Location
Clock Positions
12:00 3:00 6:00 9:00
1 12" steel w/
white coating 0.444 0.421 0.421 0.438
2 12" steel w/
white coating 0.425 0.398 0.402 0.458
3 12" steel w/
white coating 0.406 0.400 0.413 0.401
4 6" steel w/
blue coating 0.260 0.263 0.249 0.262
5 14" ductile
iron w/ black
coating

0.397 0.410 0.399 0.383
6 14" ductile
iron w/ black
coating
(exterior)

0.417 0.355 0.387 0.397
7 8" ductile
iron w/ white
coating
(exterior)

0.406 0.300 0.339 0.370
8 12" steel w/
white coating 0.363 0.363 0.358 0.360
9 8" ductile
iron w/ black
coating

0.338 0.411 0.390 0.37

Page 913 of 1105 ends

Condition Assessment of Rancho Solano Golf Course and Raw Water Pump Stations Appendix A UT Locations and Data
V&A Project No. 22-0005 A-8
Table A-2. Rancho Solano Raw Water Pump Station Raw UT Data Band Location
Clock Positions
12:00 3:00 6:00 9:00
1 10" steel w/ green
coating 0.359 0.358 0.357 0.360
2 12" steel w/ white
coating 0.357 0.358 0.357 0.365
3 12" steel w/ white
coating 0.393 0.388 0.375 0.395
4 14" steel w/ green
coating (exterior) 0.365 0.381 0.393 0.378
5 12" steel w/ white
coating 0.417 0.405 0.357 0.394

Page 914 of 1105 ends

1000 Broadway
Suite 320
Oakland, CA 94607
510.903.6600
510.903.6601, Fax

Page 915 of 1105 ends

Component Risk Results, Rehab/Replacement Projects,
and Action Plan by Facility
Appendix C

Page 916 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life
Adjusted Remaining
Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
ELEC ELEC-047 Surge Protector 5 5 20 1
Located in ATS. Red Fail light present. Has not been
replaced since last survey.

Replace surge protector with newer, currently supported model 10 6 High Replace $ 3,700
ELEC ELEC-045 System Service 2 1 40 21 3 9 Medium No Action Required ELEC ELEC-046 Motor Control Center 2 1 20 1
Previously installed Pump VFDs have been removed and
replaces with CS Starters
Eastridge Station Control Panel
Allen Bradley PLC-5
Input / Output List: CPU / DI / DI / DO /
AO / AI / PS 24V
9 Control Relays
I/O Terminal Blocks
DC Power Supplies
Battery Backups
PLC panel is part of Eastridge MCC 6 9 Med-High Schedule Long-Term Corrective Action/Rehabilitation $ 462,500 INST INST-042 Flow Element 4 4 15 -4
Frequent Malfunctions. Several parts have already been
replaced. Recommend replacement of entire unit. Replace flow meter with newer model. 9 5 Med-High Replace $ 9,157 PIPE PIPE-026 Pump Discharge Piping 3 1 50 32 Corrosion on pipe tap connection. Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-157 Yard Piping 2 2 50 34
Zone-to-zone regulating piping. Not included in 2015
assessment. 4 9 Med-High No Action Required
ELEC ELEC-083 Other (General Electrical) 2 1 20 1 6 6 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 74,000 PIPE PIPE-001 Yard Piping 2 1 50 32 3 9 Medium No Action Required PIPE PIPE-024 Pump Discharge Piping 2 1 50 32 3 9 Medium No Action Required PIPE PIPE-028 Pump Discharge Piping 2 1 50 32 3 9 Medium No Action Required PIPE PIPE-030 Pump Discharge Piping 2 1 50 32 3 9 Medium No Action Required CNTR CNTR-011 Controller 4 3 20 2 PLC model is at End of Life. Recommend replacement Replace PLC with newer model. Will require replacement
of subpanel components. 8 5 Med-High Replace $ 18,500
PIPE PIPE-023 Pump Suction Piping 1 1 50 32 Pipe is buried, unobservable (no photo) 3 9 Medium No Action Required PIPE PIPE-025 Pump Suction Piping 1 1 50 32 Pipe is buried, unobservable (no photo) 3 9 Medium No Action Required PIPE PIPE-027 Pump Suction Piping 1 1 50 32 Pipe is buried, unobservable (no photo) 3 9 Medium No Action Required PIPE PIPE-029 Pump Suction Piping 1 1 50 32 Pipe is buried, unobservable (no photo) 3 9 Medium No Action Required PIPE PIPE-158 Yard Piping 1 1 50 44 Hydrotank bypass line. 2 9 Med-Low No Action Required INST INST-043 Pressure Element 3 5 15 -4
Appears inoperable. Redundant after installation of
Rosemount DP transmitter. Recommend removal. Remove unused instrument. 10 6 High No Action Required INST INST-044 Pressure Element 4 4 15 -4
Installed haphazardly. DP lines are not well secured.

Replace.

Replace gauge with newer model. Secure differential
pressure lines to avoid bending and other damage. 9 6 Med-High Replace $ 3,885 SCDA SCDA-010 SCADA/Telemetry 2 2 10 -8 OIT is at end of supported life. Replace OIT with newer model. 7 4 Medium Replace $ 83,250 ELEC ELEC-101 Other (General Electrical) 2 2 20 1 Compressor control panel. 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 74,000 INST INST-090 Pressure Element 3 2 15 -2 7 2 Medium Increased Maintenance/Operational Adjustments HVAC HVAC-001 Wall Fan 1 1 15 -3 6 5 Medium No Action Required HVAC HVAC-013 Wall Fan 1 1 15 -3 6 5 Medium No Action Required ELEC ELEC-049 Convenience Receptacles 2 1 20 1 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 555 FIRE FIRE-001 Fire Extinguisher 1 1 15 -3 6 2 Med-Low No Action Required SECR SECR-005 Alarm Systems 1 1 15 -3 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 6,475 VALV VALV-110 D/S Isolation Valve 3 1 30 12
Moderate rust/corrosion observable on stem; paint
peeling
Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-111 D/S Isolation Valve 3 1 30 12
Moderate rust/corrosion observable on stem; paint
peeling
Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-112 D/S Isolation Valve 3 1 30 12
Moderate rust/corrosion observable on stem; paint
peeling
Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-179 Pump Control Valve 3 1 25 19
Moderate corrosion on body and bolts; Valve is
unsupported
Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-180 Pump Control Valve 3 1 25 19
Moderate corrosion on body and bolts; Valve is
unsupported
Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-287 U/S Isolation Valve 3 2 30 12 Heavy rust/corrosion observable on stem; paint peeling Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 5 4 Medium Increased Maintenance/Operational Adjustments VALV VALV-288 D/S Isolation Valve 3 2 30 12 Heavy rust/corrosion observable on stem; paint peeling Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 5 4 Medium Increased Maintenance/Operational Adjustments ELEC ELEC-048 Lighting Panel 2 1 25 6 4 5 Med-Low Increased Maintenance/Operational Adjustments ELEC GENR-011 Onsite Generator 2 1 25 7
Fuel storage: 250-gallon underbelly tank Moderate
corrosion observable on exhaust silencer. 4 4 Med-Low Increased Maintenance/Operational Adjustments Selected Assets:

Inspection Notes: New Cla Val PCV has been installed on pumps 1,2,3. New hydro tank parts have been installed, including a hydro tank bypass and isolation valves Operator Issues:
- TigerMag flowmeter
- PLC5 controller (reservoir too)
- Hydro tank plumbing is a mess, abandoned pressure transmitter - Rosemount 1151 pressure transmitter on hydrotank
- Wire mess next to backflow device outside
- Fiber to Reservoir Vault
- Panelview 600 HMI
Recommended Rehab/Replacement Estimated Cost $738,797
Facility: 011 Eastridge Zone 3 Pump Station (Hydro)
Inspection Date: 6/14/2022
Inspectors: Tyler Newman, Christian Neher
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 917 of 1105 ends

TANK TANK-001 Hydropneumatic Tank 2 1 30 12 4 5 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-004 Pressure Relief Valve 2 1 25 7 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-113 D/S Isolation Valve 2 1 30 12 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-181 Pump Control Valve 2 1 25 7 Minor corrosion on bolts 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-300 U/S Isolation Valve 2 1 30 12 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-343 Air Valve 3 2 30 24 Corrosion observable and paint peeling.

Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 5 2 Med-Low Increased Maintenance/Operational Adjustments PUMP PUMP-001 Pump 2 3 30 12
Continue operating pump to failure; assess the pump for wear on the impellers and rotating parts; assess the
isolation valves to be sure there is no recirculation. 6 4 Medium Increased Maintenance/Operational Adjustments VALV VALV-220 U/S Isolation Valve 1 1 30 12
Valve is buried, below the concrete slab. Did not
observe. 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-221 U/S Isolation Valve 1 1 30 12
Valve is buried, below the concrete slab. Did not
observe. 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-222 U/S Isolation Valve 1 1 30 12
Valve is buried, below the concrete slab. Did not
observe. 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-223 U/S Isolation Valve 1 1 30 12
Valve is buried, below the concrete slab. Did not
observe. 4 4 Med-Low Increased Maintenance/Operational Adjustments COMP COMP-001 Air Compressor 1 1 20 2 5 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 2,775 MOTR MOTR-001 Motor 2 1 30 12 4 4 Med-Low No Action Required MOTR MOTR-002 Motor 2 1 30 12 4 4 Med-Low No Action Required MOTR MOTR-003 Motor 2 1 30 12 4 4 Med-Low No Action Required MOTR MOTR-004 Motor 2 1 30 12 4 4 Med-Low No Action Required PUMP PUMP-002 Pump 2 3 30 12
Continue operating pump to failure; assess the pump for wear on the impellers and rotating parts; assess the
isolation valves to be sure there is no recirculation. 6 4 Medium Increased Maintenance/Operational Adjustments PUMP PUMP-003 Pump 3 3 30 12
Concrete chipping away below base plate. Rebuilt in
2013.. Rebuilt in 2013.

Continue operating pump to failure; assess the pump for wear on the impellers and rotating parts; assess the
isolation valves to be sure there is no recirculation. 6 4 Medium Increased Maintenance/Operational Adjustments PUMP PUMP-004 Pump 2 5 30 12
Coordinate with manufacturer to verify correct pump
curve. 8 4 Medium Increased Maintenance/Operational Adjustments LGHT LGHT-021 Lighting 2 1 20 2 5 2 Med-Low No Action Required VALV VALV-002 Air Valve 2 1 30 12 4 2 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-178 Pump Control Valve 2 1 25 19 Minor corrosion on bolts; Valve is unsupported 3 4 Med-Low No Action Required VALV VALV-301 U/S Isolation Valve 2 1 30 12 4 3 Med-Low Increased Maintenance/Operational Adjustments ACCS ACCS-001 Gravel 1 1 30 12 4 3 Med-Low No Action Required SEAL SEAL-001 Seals 2 1 30 12 Minor corrosion 4 3 Med-Low No Action Required SEAL SEAL-002 Seals 2 1 30 12 Minor corrosion 4 3 Med-Low No Action Required SEAL SEAL-003 Seals 2 1 30 12 Minor corrosion 4 3 Med-Low No Action Required SEAL SEAL-004 Seals 2 1 30 12 Minor corrosion 4 3 Med-Low No Action Required BLDG BLDG-001 Structure 1 1 50 32
Coating: Paint;
Dimensions: 38' x 24' x 9'';
Personnel Access: 6' Wide double-doors
Equipment Ingress/Egress: Hatches on Roof
3 4 Med-Low No Action Required
BLDG BLDG-002 Roof 1 1 50 32 3 4 Med-Low No Action Required VALV VALV-341 U/S Isolation Valve 1 1 30 24 U/S isolation gate valve for Hydrotank bypass line. 2 4 Low No Action Required VALV VALV-342 D/S Isolation Valve 1 1 30 24 D/S isolation gate valve for Hydrotank bypass line. 2 4 Low No Action Required DRNG DRNG-001 Drainage 1 1 50 32 3 3 Low No Action Required FENC FENC-001 Fencing - CMU 1 1 40 22 3 3 Low No Action Required WATR WATR-001 Water Service 1 1 50 32 3 3 Low No Action Required c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 918 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life
Adjusted Remaining
Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
CNTR CNTR-004 Controller 4 3 20 4 PLC model is at End of Life. Recommend replacement Replace PLC with newer model. Will require
replacement of subpanel components. 8 5 Med-High Replace $ 18,500 ELEC ELEC-008 System Service 3 2 40 25 Breaker is from 2011. Still functions, but old. 5 9 Med-High No Action Required ELEC ELEC-009 Motor Control Center 2 2 20 5
15kVA transformer located in PLC panel. Heat source
and unsafe mix of high and low V. Recommend
relocating.

Soft starters perform well and in good condition.

Gold Ridge Zone 2 PS Control Panel
Allen Bradley PLC-5;
Input / Output List: CPU / DI / DI / DO /;
AO / AI / PS 24V
9 Control Relays; I/O Terminal Blocks; 480V
Transformer PLC panel is part of Gold Ridge Z2 MCC.
480V Transformer is located at bottom of panel,
mixing high and low voltage. Safety Issue.

Space permitting, transformer and all high voltage
wiring should be removed from PLC panel and moved
to a separate panel 5 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-159 Yard Piping 2 1 50 34
Zone-to-zone regulating piping; discharge to ground,
not included in 2015 assessment. 3 9 Medium No Action Required PIPE PIPE-002 Yard Piping 2 1 50 34 3 9 Medium No Action Required PIPE PIPE-031 Pump Suction Piping 2 1 50 34 ARV threads corroded 3 9 Medium No Action Required PIPE PIPE-032 Pump Discharge Piping 2 1 50 34 3 9 Medium No Action Required PIPE PIPE-033 Pump Suction Piping 2 1 50 34 3 9 Medium No Action Required PIPE PIPE-034 Pump Discharge Piping 2 1 50 34 3 9 Medium No Action Required PIPE PIPE-035 Pump Suction Piping 2 1 50 34 ARV threads corroded 3 9 Medium No Action Required PIPE PIPE-036 Pump Discharge Piping 2 1 50 34 3 9 Medium No Action Required PIPE PIPE-037 Pump Suction Piping 2 1 50 34 ARV threads corroded 3 9 Medium No Action Required PIPE PIPE-038 Pump Discharge Piping 2 1 50 34 3 9 Medium No Action Required PIPE PIPE-132 Yard Piping 2 1 50 34 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required INST INST-019 Pressure Element 3 2 15 0
Gage pressure Transmitter Functions, but model
obsolete and discontinued, and requires frequent
recalibration. Replace gauge with newer model 7 6 Med-High Replace $ 3,885 INST INST-020 Pressure Element 3 2 15 0
Discharge Pressure Transmitter Functions, but model
obsolete and discontinued, and requires frequent
recalibration. Replace gauge with newer model 7 6 Med-High Replace $ 3,885 HVAC HVAC-017 Roof Fan 2 2 15 -1 Roof fan not included in 2015 assessment 7 5 Medium No Action Required INST INST-018 Flow Element 3 2 15 0 Functions, but discontinued.

Eventual replacement is recommended due to lack of
current device support. 7 5 Medium No Action Required
SCDA SCDA-002 SCADA/Telemetry 2 2 10 -6
New radio installed but not cut over. Recommend
finishing cutover and removal of old radio.

Finish migration of communications onto new radio
system and remove old radio from panel. 7 4 Medium Increased Maintenance/Operational Adjustments VALV VALV-298 Other (Valves) 2 1 25 9 4 6 Medium Increased Maintenance/Operational Adjustments VALV VALV-299 Other (Valves) 2 1 25 9 4 6 Medium Increased Maintenance/Operational Adjustments VALV VALV-347 Other (Valves) 2 2 25 9
Isolation gate valve for zone-to-zone PRV, not
included in 2015 assessment. 5 5 Medium Increased Maintenance/Operational Adjustments ELEC ELEC-082 Surge Protector 1 1 20 20
Replaced 6 months ago. Brand new. Same model as
prior 2 6 Med-Low No Action Required
LGHT LGHT-007 Lighting 2 3 20 5
Takes a while to warm up. Recommend LED
replacement.

Replace flourescent lighting with LEDs for more
reliability and efficiency. 6 2 Med-Low Replace $ 33,744 VALV VALV-295 Pressure Relief Valve 0 1 25 9 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-005 Other (Valves) 1 1 25 9 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-008 Other (Valves) 1 1 25 9 D/S isolation for zone-to-zone PRV. 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-170 Other (Valves) 1 1 25 9 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-171 Other (Valves) 1 1 25 9 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-172 Other (Valves) 1 1 25 9 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-182 Pump Control Valve 2 1 25 9
Corrosion on bolts and on small diameter piping
connections Replace corroded parts and recoat the valve 4 4 Med-Low Increased Maintenance/Operational Adjustments Inspection Notes:

Operator Issues:

Recommended Rehab/Replacement Estimated Cost
Selected Assets:

Staff would like fluorescent interior lights and non-LED exterior lights installed, Allen-Bradley SMC Flex VFDs for pump motors, PLC5 Controller, ABB MagMaster flowmeter, Rosemount 1151 Pressure transmitters, Panelview 600 HMI, Em Gen Load Bank, and to move the transformer out of PLC cabinet
Pump 4 impeller has been trimmed, and the hydro tank has been rehabilitated (plates welded for rust) $60,014
Facility:

Inspection Date:

Inspectors:
003 Gold Ridge Zone 2 Pump Station (Hydro)
6/15/2022
Tyler Newman, Christian Neher
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 919 of 1105 ends

VALV VALV-183 Pump Control Valve 2 1 25 9
Corrosion on bolts and on small diameter piping
connections Replace corroded parts and recoat the valve 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-184 Pump Control Valve 2 1 25 9 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-185 Pump Control Valve 2 1 25 9 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-346 U/S Isolation Valve 2 2 30 14
U/S isolation for zone-to-zone PRV, not included in
2015 assessment. 4 4 Med-Low No Action Required
COUP COUP-064 Other (Coupling) 2 2 20 4
U/S Isolation for Hydrotank not included in 2015
assessment 5 3 Med-Low Increased Maintenance/Operational Adjustments FIRE FIRE-017 Fire Extinguisher 0 0 15 -1 5 2 Med-Low Inspect to Create Action Plan ELEC ELEC-010 Lighting Panel 2 1 25 10 4 5 Med-Low Increased Maintenance/Operational Adjustments ELEC ELEC-089 Other (General Electrical) 2 1 20 14
Automatic transfer switch. Exercised regularly. Good
condition 3 5 Med-Low No Action Required
TANK TANK-002 Hydropneumatic Tank 2 1 30 14 3 5 Med-Low No Action Required VALV VALV-007 Pressure Relief Valve 1 1 25 9 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-009 Pressure Relief Valve 1 1 25 9 Over pressure relief, angle style, discharge to ground. 4 4 Med-Low Increased Maintenance/Operational Adjustments ELEC ELEC-088 Other (General Electrical) 1 2 20 17
DC Battery backup for plc panel. One battery less than
80% charged per light, but otherwise good condition. 3 5 Med-Low No Action Required ELEC GENR-005 Onsite Generator 1 1 25 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-348 Air Valve 2 2 30 14
Double air-valve assembly on Pump 1 suction, not
included in 2015 assessment. Corrosion on threads
connecting to suction pipe.

Replace pipe nipple connecting to pump suction
piping 4 2 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-349 Air Valve 2 2 30 14
Double air-valve assembly on Pump 2 suction, not
included in 2015 assessment. Corrosion on threads
connecting to suction pipe. Paint peeling on valve.

Replace pipe nipple connecting to pump suction
piping 4 3 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-350 Air Valve 2 2 30 14
Double air-valve assembly on Pump 3 suction, not
included in 2015 assessment. Corrosion on threads
connecting to suction pipe and top of valve. Evidence
of minor leakage.

Replace pipe nipple connecting to pump suction
piping 4 2 Med-Low Increased Maintenance/Operational Adjustments COUP COUP-003 Other (Coupling) 3 1 20 4 Rubber deteriorating 4 3 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-114 D/S Isolation Valve 2 1 30 14 3 4 Med-Low No Action Required VALV VALV-115 D/S Isolation Valve 2 1 30 14 3 4 Med-Low No Action Required VALV VALV-116 D/S Isolation Valve 2 1 30 14 3 4 Med-Low No Action Required VALV VALV-117 D/S Isolation Valve 2 1 30 14 3 4 Med-Low No Action Required VALV VALV-224 U/S Isolation Valve 2 1 30 14 3 4 Med-Low No Action Required VALV VALV-225 U/S Isolation Valve 2 1 30 14 3 4 Med-Low No Action Required VALV VALV-226 U/S Isolation Valve 2 1 30 14 3 4 Med-Low No Action Required VALV VALV-227 U/S Isolation Valve 2 1 30 14 3 4 Med-Low No Action Required VALV VALV-297 Air Valve 2 2 30 14
Corrosion on connection to main pipe, evidence of
minor leak. 4 2 Med-Low No Action Required
COMP COMP-002 Air Compressor 1 1 20 4 4 2 Med-Low Increased Maintenance/Operational Adjustments COUP COUP-004 D/S Coupling 2 1 20 4 4 3 Med-Low Increased Maintenance/Operational Adjustments COUP COUP-005 D/S Coupling 2 1 20 4 4 3 Med-Low Increased Maintenance/Operational Adjustments COUP COUP-006 D/S Coupling 2 1 20 4 4 3 Med-Low Increased Maintenance/Operational Adjustments COUP COUP-007 D/S Coupling 2 1 20 4 4 3 Med-Low Increased Maintenance/Operational Adjustments COUP COUP-032 U/S Coupling 2 1 20 4 4 3 Med-Low Increased Maintenance/Operational Adjustments COUP COUP-033 U/S Coupling 2 1 20 4 4 3 Med-Low Increased Maintenance/Operational Adjustments COUP COUP-035 U/S Coupling 2 1 20 4 4 3 Med-Low Increased Maintenance/Operational Adjustments COUP COUP-036 U/S Coupling 2 1 20 4 4 3 Med-Low Increased Maintenance/Operational Adjustments BLDG BLDG-003 Structure 1 1 50 34 3 4 Med-Low No Action Required BLDG BLDG-004 Roof 1 1 50 34 3 4 Med-Low No Action Required MOTR MOTR-005 Motor 2 1 30 14 3 4 Med-Low No Action Required MOTR MOTR-006 Motor 2 1 30 14 3 4 Med-Low No Action Required MOTR MOTR-008 Motor 2 1 30 14 3 4 Med-Low No Action Required MOTR MOTR-009 Motor 2 1 30 14 3 4 Med-Low No Action Required PUMP PUMP-005 Pump 2 3 30 14
Nameplate Data: 1000 gpm, 100' TDH, 10.69"
impeller
Tested Data: 960 gpm, 95' TDH
Pump #4 impeller has been trimmed recently.

Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess
the isolation valves to be sure there is no
recirculation. 5 3 Med-Low Increased Maintenance/Operational Adjustments PUMP PUMP-006 Pump 2 3 30 14
Nameplate Data: 1000 gpm, 100' TDH, 10.69"
impeller
Tested Data: 942 gpm, 95' TDH
Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess
the isolation valves to be sure there is no
recirculation. 5 3 Med-Low Increased Maintenance/Operational Adjustments PUMP PUMP-007 Pump 2 3 30 14
Nameplate Data: 1000 gpm, 100' TDH, 10.69"
impeller
Tested Data: 914 gpm, 95' TDH
Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess
the isolation valves to be sure there is no
recirculation. 5 3 Med-Low Increased Maintenance/Operational Adjustments c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 920 of 1105 ends

PUMP PUMP-008 Pump 2 3 30 14
Nameplate Data: 1385 gpm, 110' TDH, 12.09"
impeller
Tested Data: 1373 gpm, 104' TDH
Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess
the isolation valves to be sure there is no
recirculation. 5 3 Med-Low Increased Maintenance/Operational Adjustments ELEC ELEC-011 Convenience Receptacles 2 1 20 5 Equipped with GFI. 4 2 Med-Low Increased Maintenance/Operational Adjustments LGHT LGHT-005 Lighting 2 1 20 5
Adequate lighting. Good condition, but not brand
new. 4 2 Med-Low No Action Required
LGHT LGHT-006 Lighting 1 1 20 5 Appears almost new. 4 2 Med-Low No Action Required INST INST-002 Level Sight Glass 1 1 30 15 3 4 Med-Low No Action Required DRNG DRNG-002 Drainage 1 1 50 34 3 3 Low No Action Required VALV VALV-006 Air Valve 2 1 30 14
Corrosion on threads connecting to main pipe. Paint
peeling on valve. Replace pipe nipple connecting to main piping 3 2 Low Increased Maintenance/Operational Adjustments VALV VALV-296 Air Valve 2 1 30 14 3 2 Low No Action Required WATR WATR-002 Water Service 2 1 50 34 Corrosion on threads connecting to main pipe. 3 3 Low No Action Required BLDG BLDG-042 Roll-up Door 2 1 50 34 Roll-up door not included in 2015 assessment. 3 3 Low No Action Required ACCS ACCS-002 Concrete 1 1 50 34 3 3 Low No Action Required FENC FENC-002 Fencing - Chain Link 1 1 40 24 3 3 Low No Action Required SEAL SEAL-006 Seals 2 1 30 14 Corrosion on bolt threads 3 3 Low No Action Required SEAL SEAL-007 Seals 2 1 30 14 Corrosion on bolt threads 3 3 Low No Action Required SEAL SEAL-005 Seals 1 1 30 14 3 3 Low No Action Required SEAL SEAL-008 Seals 1 1 30 14 3 3 Low No Action Required INST INST-091 Pressure Element 1 1 15 13 Differential Pressure gauge Replacement for INST-017. 2 2 Low No Action Required INST INST-092 Pressure Element 1 1 15 13
D/S gauge for zone-to-zone PRV not included in 2015
assessment Replace pipe nipple connecting to main piping 2 2 Low Increased Maintenance/Operational Adjustments c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 921 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life
Adjusted Remaining
Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
ELEC ELEC-013 Motor Control Center 3 3 20 -12 8 9 High Schedule Long-Term Corrective Action/Rehabilitation $ 462,500 SCDA SCDA-003 SCADA/Telemetry 4 3 10 -22
Many old components.

New radio installed but not cut over. Recommend
finishing cutover and removal of old radio.

Finish migration of communications onto new radio
system and remove old radio from panel. 8 4 Medium No Action Required CNTR CNTR-005 Controller 4 3 20 -12
PLC model is at End of Life. Recommend
replacement
Replace PLC with newer model. Will require
replacement of subpanel components. 8 5 Med-High Replace $ 18,500 ELEC ELEC-012 System Service 2 2 40 8 5 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-039 Pump Suction Piping 3 2 50 18 Paint peeling, corrosion on pressure gauge nipple Recoat the piping 5 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-133 Yard Piping 3 2 50 18 Paint peeling, corrosion on flange bolts Recoat the piping 5 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-003 Yard Piping 2 1 50 18 4 9 Med-High No Action Required PIPE PIPE-040 Pump Discharge Piping 2 2 50 18 5 9 Med-High No Action Required PIPE PIPE-041 Pump Suction Piping 2 2 50 18 5 9 Med-High No Action Required PIPE PIPE-042 Pump Discharge Piping 2 2 50 18 Paint peeling, corrosion on flange bolts 5 9 Med-High No Action Required ELEC ELEC-015 Lighting Panel 3 3 25 -7
Should not be enclosed in Control Panel. Recommend
relocating Lighting panel to location outside of RTU
panel.

Space permitting, breaker panel and associated wiring
should be removed from PLC panel and moved
outside of the MCC to a nearby wall. 8 5 Med-High Schedule Long-Term Corrective Action/Rehabilitation $ 13,875 INST INST-022 Flow Element 1 3 15 9
Replaced with new meter. PETS confirmed more than
10% flow deviation. Recalibrate flow meter to reduce flow deviation. 5 5 Medium Increased Maintenance/Operational Adjustments COUP COUP-061 Other (Coupling) 3 2 20 -12
Significant offset between valves, rubber
deteriorating. Replace coupling 7 3 Medium Replace $ 463 COUP COUP-062 Other (Coupling) 3 2 20 -12 Rubber deteriorating Replace coupling 7 3 Medium Replace $ 463 VALV VALV-011 Air Valve 2 1 30 -2 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 18,500 VALV VALV-012 Air Valve 2 1 30 -2 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 18,500 SEAL SEAL-009 Seals 3 2 30 -2 Paint peeling, corrosion on bolts Recoat the seal, replace bolts 7 3 Medium Increased Maintenance/Operational Adjustments SEAL SEAL-010 Seals 3 2 30 -2 Paint peeling, corrosion on bolts Recoat the seal, replace bolts 7 3 Medium Increased Maintenance/Operational Adjustments GENR GENR-006 Adaptor for Portable Unit 2 2 20 -12 Slightly dirty, but otherwise functional 7 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 9,250 MOTR MOTR-010 Motor 2 2 30 -2 Paint peeling Inspect motor and rebuild as necessary 7 4 Medium Increased Maintenance/Operational Adjustments MOTR MOTR-011 Motor 2 2 30 -2 Paint peeling Inspect motor and rebuild as necessary 7 4 Medium Increased Maintenance/Operational Adjustments PUMP PUMP-009 Pump 2 4 30 -2
Install VFD and/or pressure controls or Replace. See
recommendations in Table 2-7 9 3 Med-High Replace $ 37,000 PUMP PUMP-010 Pump 2 4 30 -2
Install VFD and/or pressure controls or Replace. See
recommendations in Table 2-7 9 3 Med-High Replace $ 37,000 ELEC ELEC-016 Convenience Receptacles 2 2 20 -12
Convenience Receptacles
125V / 20A & GFI
Enclosure
Manufacturer: Hoffman
Model: A48h36DLP
Size: 48”Hx36”Wx12”D
Rating: NEMA 12
Construction:14 gauge steel
Finish: ANSI 61 Gray Previously included DO Relays,
DC power supply, and DC/DC converter were not
found during site walk 7 2 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 555 FIRE FIRE-002 Fire Extinguisher 2 2 15 -17 7 2 Medium No Action Required INST INST-023 Pressure Element 2 2 15 -17 7 5 Medium No Action Required SECR SECR-009 Alarm Systems 1 1 15 -17 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 6,475 INST INST-021 Level Element 0 0 15 -17
Only found readout device. Instrument is likely at
reservoir. Unable to confirm condition. 5 4 Medium Inspect to Create Action Plan BLDG BLDG-005 Structure 2 2 50 18 5 4 Medium Increased Maintenance/Operational Adjustments INST INST-061 Flow Element 0 0 15 9 2 5 Low Inspect to Create Action Plan BLDG BLDG-006 Roof 1 1 50 18 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-013 Pressure Relief Valve 1 1 25 19 2 4 Low No Action Required VALV VALV-014 Pressure Relief Valve 1 1 25 19 2 4 Low No Action Required VALV VALV-186 Pump Control Valve 1 1 25 19 2 4 Low No Action Required VALV VALV-187 Pump Control Valve 1 1 25 19 2 4 Low No Action Required VALV VALV-118 D/S Isolation Valve 1 1 30 24 2 4 Low No Action Required VALV VALV-119 D/S Isolation Valve 1 1 30 24 2 4 Low No Action Required VALV VALV-228 U/S Isolation Valve 1 1 30 24 2 4 Low No Action Required Selected Assets:

Inspection Notes: City has installed new gate valves, new backpressure valve, PRV and cla val PCV 2016/2017. Also new effluent shutoff valve in street has been installed.

Operator Issues:
- Wood structure
- Old MCC with many modifications
- Non-LED exterior lights
- Very old transfer switch
- PLC 5 controller, modified panel, ad-hoc flowmeter transmitter installation - Lighting panel is inside PLC panel, not safe for non-electrical personnel - Radio antenna coax not well-secured
Recommended Rehab/Replacement Estimated Cost $623,080
Facility: 004 Mangels Zone 2 Pump Station
Inspection Date: 6/14/2022
Inspectors: Tyler Newman, Christian Neher
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 922 of 1105 ends

VALV VALV-229 U/S Isolation Valve 1 1 30 24 2 4 Low No Action Required WATR WATR-003 Water Service 2 1 50 18 4 3 Med-Low No Action Required ACCS ACCS-003 Concrete 1 1 50 18 4 3 Med-Low No Action Required VALV VALV-010 Other (Valves) 1 1 25 19 U/S isolation gate valve for flow meter. 2 4 Low No Action Required VALV VALV-015 Other (Valves) 1 1 25 19 2 4 Low No Action Required VALV VALV-016 Other (Valves) 1 1 25 19 2 4 Low No Action Required VALV VALV-279 Other (Valves) 1 1 25 19 Isolation valve for flow meter bypass line. 2 4 Low No Action Required VALV VALV-280 Other (Valves) 1 1 25 19 2 4 Low No Action Required VALV VALV-281 Other (Valves) 1 1 25 19 2 4 Low No Action Required VALV VALV-339 U/S Isolation Valve 1 1 30 24
Isolation gate valve on suction piping, not included in 2015 assessment. 2 4 Low No Action Required
VALV VALV-340 D/S Isolation Valve 1 1 30 24
D/S isolation gate valve for flow meter, not included
in 2015 assessment. 2 4 Low No Action Required
LGHT LGHT-008 Lighting 1 1 20 19 Appear recently replaced. Adequate lighting. 2 2 Low No Action Required INST INST-024 Pressure Element 1 1 15 14
Ashcroft Pressure Transmitter
EL Rating: 15A, 125/250/480VAC 1/2A,125VDC
Range: 200PSI
Proof: 1000PSI
MAT'L: BUNA/ST.ST Replaced with Ashcroft. Good
Condition 2 2 Low No Action Required
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 923 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life
Adjusted Remaining
Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
ELEC ELEC-018 Motor Control Center 2 1 20 -4
Pump bucket contents previously melted
completely, and have since been replaced. Currently
in very good condition. Radio in middle of cutover.

Panel overcrowded and obsolete. Needs replacing.

Replace subpanel and panel components to avoid
overcrowding. 6 9 54 Med-High Schedule Long-Term Corrective Action/Rehabilitation $ 462,500 CNTR CNTR-006 Controller 4 3 20 -4
PLC model is at End of Life. Recommend
replacement
Replace PLC with newer model. Will require
replacement of subpanel components. 8 5 40 Med-High Replace $ 18,500 ELEC ELEC-017 System Service 2 2 40 16 5 9 45 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-004 Yard Piping 2 1 50 26 3 9 27 Medium No Action Required PIPE PIPE-044 Pump Discharge Piping 2 1 50 26 3 9 27 Medium No Action Required PIPE PIPE-045 Pump Suction Piping 2 1 50 26 3 9 27 Medium No Action Required PIPE PIPE-046 Pump Discharge Piping 2 1 50 26 3 9 27 Medium No Action Required PIPE PIPE-047 Pump Suction Piping 2 1 50 26 3 9 27 Medium No Action Required PIPE PIPE-048 Pump Discharge Piping 2 1 50 26 3 9 27 Medium No Action Required PIPE PIPE-134 Yard Piping 2 1 50 26 3 9 27 Medium No Action Required PIPE PIPE-043 Pump Suction Piping 2 1 50 26 3 9 27 Medium No Action Required ELEC ELEC-085 Other (General Electrical) 3 3 20 -4
Old radio still present and frequently loses
connection. New radio present but hasn’t been cut
over.

Finish migration of communications onto new
radio system and remove old radio from panel. 8 6 48 Med-High Increased Maintenance/Operational Adjustments INST INST-026 Pressure Element 3 3 15 -9 Model is at End of Life. Recommend replacement Replace gauge with newer model 8 6 48 Med-High Replace $ 3,885 ELEC ELEC-019 Lighting Panel 2 1 25 1 6 5 30 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 13,875 VALV VALV-019 Pressure Relief Valve 2 1 25 1 6 4 24 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 6,475 VALV VALV-188 Pump Control Valve 2 1 25 1 6 4 24 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 31,349 VALV VALV-189 Pump Control Valve 2 1 25 1 6 4 24 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 31,349 VALV VALV-190 Pump Control Valve 2 1 25 1 6 4 24 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 31,349 HVAC HVAC-002 Roof Fan 2 1 15 -9 6 5 30 Medium No Action Required SECR SECR-014 Alarm Systems 1 1 15 -9 6 2 12 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 6,475 FIRE FIRE-003 Fire Extinguisher 2 2 15 -9 7 2 14 Medium No Action Required INST INST-027 Pressure Element 3 2 15 -9 Old but working. 7 2 14 Medium Increased Maintenance/Operational Adjustments SCDA SCDA-004 SCADA/Telemetry 0 0 10 -14
No screens viewed. No OITs.

New radio installed but not cut over. Recommend
finishing cutover and removal of old radio.

Finish migration of communications onto new
radio system and remove old radio from panel. 5 4 20 Medium Increased Maintenance/Operational Adjustments COUP COUP-051 D/S Coupling 3 2 20 12 Rubber deterioration Replace coupling 5 3 15 Med-Low Replace $ 606 COUP COUP-052 D/S Coupling 3 2 20 12 Rubber deterioration Replace coupling 5 3 15 Med-Low Replace $ 606 COUP COUP-053 D/S Coupling 3 2 20 12
Significant offset between valves. Rubber
deterioration Replace coupling 5 3 15 Med-Low Replace $ 606 SEAL SEAL-013 Seals 3 2 30 6 Corrosion/moisture observed Replace seal 5 3 15 Med-Low Replace $ 5,550 ELEC ELEC-091 Other (General Electrical) 2 2 20 17
DC battery backup for RTU panel.

Battery Tender 12V Charger
Batteries Replaced 8-2019 4 5 20 Med-Low No Action Required VALV VALV-230 U/S Isolation Valve 1 1 30 6 4 4 16 Med-Low Increased Maintenance/Operational Adjustments INST INST-025 Flow Element 1 1 15 13
Rosemount Flow Transmitter
Supply: 90-250 VAC 50/60Hz, 0.45A, 40VA
Output: Modbus RS485, Pulse 0-10,000 Hz
Mfg Date 2020-05
Ambient Temp: -29C to +60C
Type 4X IP66 Replaced 2020. 2 5 10 Low No Action Required MOTR MOTR-012 Motor 2 1 30 6 4 4 16 Med-Low No Action Required MOTR MOTR-013 Motor 2 1 30 6 4 4 16 Med-Low No Action Required MOTR MOTR-014 Motor 2 1 30 6 4 4 16 Med-Low No Action Required PUMP PUMP-011 Pump 2 1 30 6
Continue operating pumps to failure.

See recommendations in Table 2-7 4 3 12 Med-Low No Action Required PUMP PUMP-012 Pump 2 2 30 6
Continue operating pumps to failure.

See recommendations in Table 2-7 5 3 15 Med-Low No Action Required PUMP PUMP-013 Pump 2 1 30 6
Continue operating pumps to failure.

See recommendations in Table 2-7 4 3 12 Med-Low No Action Required FENC FENC-003 Fencing - Chain Link 2 1 40 6 4 3 12 Med-Low No Action Required DRNG DRNG-003 Drainage 2 2 50 26 4 3 12 Med-Low No Action Required VALV VALV-018 Air Valve 2 1 30 6 4 2 8 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-276 Air Valve 2 1 30 6 4 2 8 Med-Low Increased Maintenance/Operational Adjustments BLDG BLDG-007 Structure 1 1 50 26 3 4 12 Med-Low No Action Required Selected Assets:

Inspection Notes: All new gate valves and flow meter. Same Cla Val PCV and PRV. Note: the check in the street doesn’t hold zone 2 to 1 so a valve was closed in the street.

Operator Issues:
- Wood structure
- Old MCC
- PLC5 controller, panel is a disorganized
- Phase monitor takes power directly from MCC busbar, only upstream breaker is the building main - Rosemount 1151 pressure transmitters
- Main Breaker replaced twice
- Radio Antenna Blocked by trees
Recommended Rehab/Replacement Estimated Cost $613,126
Facility: 005 Martin Hill Zone 2 Pump Station
Inspection Date: 6/14/2022
Inspectors: Tyler Newman, Christian Neher
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 924 of 1105 ends

BLDG BLDG-008 Roof 1 1 50 26 3 4 12 Med-Low No Action Required VALV VALV-120 D/S Isolation Valve 1 1 30 29 2 4 8 Low No Action Required VALV VALV-121 D/S Isolation Valve 1 1 30 29 2 4 8 Low No Action Required VALV VALV-122 D/S Isolation Valve 1 1 30 29 2 4 8 Low No Action Required VALV VALV-231 U/S Isolation Valve 1 1 30 29 2 4 8 Low No Action Required VALV VALV-232 U/S Isolation Valve 1 1 30 29 2 4 8 Low No Action Required BLDG BLDG-009 Roll-up Door 2 2 50 26 4 3 12 Med-Low No Action Required SEAL SEAL-011 Seals 2 1 30 6 4 3 12 Med-Low No Action Required SEAL SEAL-012 Seals 2 1 30 6 4 3 12 Med-Low No Action Required ACCS ACCS-004 Concrete 1 1 50 16 4 3 12 Med-Low No Action Required VALV VALV-017 Other (Valves) 1 1 25 19 2 4 8 Low No Action Required VALV VALV-274 Other (Valves) 1 1 25 24 2 4 8 Low No Action Required VALV VALV-275 Other (Valves) 1 1 25 24 2 4 8 Low No Action Required VALV VALV-344 U/S Isolation Valve 1 1 30 29 Isolation gate valve for zone-to-zone PRV. 2 4 8 Low No Action Required VALV VALV-345 D/S Isolation Valve 1 1 30 29 Isolation gate valve for zone-to-zone PRV. 2 4 8 Low No Action Required GENR GENR-007 Adaptor for Portable Unit 1 1 20 19 Replaced 2021. 2 3 6 Low No Action Required WATR WATR-004 Water Service 2 1 50 26 3 3 9 Low No Action Required c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 925 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life
Adjusted Remaining
Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
ELEC ELEC-022 Motor Control Center 4 4 20 -11
Pump 3 transformer insulation has leaked residue onto
bottom of bucket. No sign of water intrusion. P1
contractor buzzes very loudly. Significant maintenance
required.

Paradise Valler Zone 2 PS Control Panel
Allen Bradley PLC-5;
Input / Output List: CPU / DI / DI / DO /;
AO / AI / PS 24V
6 Control Relays I/O Terminal Blocks; DC Power
Supplies; Battery Backups & Chargers
PLC panel: McCrometer Flow Meter (Panel Door) is
part of MCC
Replace transformers with newer
model, clean residue from panel. 9 9 High Increased Maintenance/Operational Adjustments INST INST-036 Level Element 0 0 15 -16
Readout for level element at reservoir. Unable to
assess condition or performance of level transmitter. 5 8 Med-High Inspect to Create Action Plan SCDA SCDA-005 SCADA/Telemetry 3 3 10 -21
New radio installed but not cut over. Recommend
finishing cutover and removal of old radio.

Finish migration of communications
onto new radio system and remove
old radio from panel. 8 4 Medium No Action Required
CNTR CNTR-007 Controller 4 3 20 -11 PLC model is at End of Life. Recommend replacement Replace PLC with newer model. Will
require replacement of subpanel
components. 8 5 Med-High Replace $ 18,500
ELEC ELEC-021 System Service 2 2 40 9 Main breaker has been replaced several times. 5 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-049 Pump Suction Piping 3 1 50 19 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-050 Pump Discharge Piping 3 1 50 19 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-051 Pump Suction Piping 3 1 50 19 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-052 Pump Discharge Piping 3 1 50 19 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-053 Pump Suction Piping 3 1 50 19 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-054 Pump Discharge Piping 3 1 50 19 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-135 Yard Piping 3 1 50 19 Corrosion observable, paint peeling. 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-005 Yard Piping 2 1 50 19 4 9 Med-High No Action Required PUMP PUMP-014 Pump 2 3 30 -1 Actual flowrate is significantly below rated flowrate.

Continue operating pumps to failure.

See recommendations in Table 2-7 8 3 Medium No Action Required PUMP PUMP-015 Pump 2 3 30 -1 Actual flowrate is significantly below rated flowrate.

Assess the pump for wear on the
impellers and rotating parts; assess
the isolation valves to be sure there is
no recirculation.

See recommendations in Table 2-7 8 3 Medium Increased Maintenance/Operational Adjustments PUMP PUMP-016 Pump 2 3 30 -1
Actual flowrate is significantly below rated flowrate.

Stem shakes when pump is on. Pump #3 recently
rebuilt
Continue operating pumps to failure.

See recommendations in Table 2-7 8 3 Medium No Action Required INST INST-040 Pressure Element 3 3 15 -16
Suction side pressure transmitter.

Range: 0-150PSI Obsolete and difficult to calibrate.

Client plans to replace with new model. Replace gauge with newer model 8 6 Med-High Replace $ 3,885 HVAC HVAC-003 Wall Fan 2 1 15 -16 6 5 Medium No Action Required COUP COUP-054 D/S Coupling 2 1 20 -11 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 COUP COUP-055 D/S Coupling 2 1 20 -11 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 COUP COUP-056 D/S Coupling 2 1 20 -11 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 Selected Assets:

Inspection Notes: City has rebuilt pump 3, installed new Cla Val PCV on all pumps, new gate and butterfly valves inside, outside and underground. One valve was buried inoperable in place. Installed new PRV, flow meter and above and below ground ARVs.

Operator Issues:
- MCC is very old with lots of modifications, abandoned light and switch(?) in weather wrap - PLC 5 controller, panel is old and highly modified, ad-hoc flowmeter transmitter placement - Rosemount 1151 Pressure transmitter
- Fluorescent interior lights
- Ventilation fan for pump building is old
- Autotransformer starters for pump motors
- Motor overloads often nuisance trip
- Main Breaker (Siemens) has been replaced 3 times
- Roof (sunshade) over MCC
Recommended Rehab/Replacement Estimated Cost $47,883
Facility: 006 Paradise Valley Zone 2 Pump Station
Inspection Date: 6/15/2022
Inspectors: Tyler Newman, Christian Neher
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 926 of 1105 ends

MOTR MOTR-015 Motor 2 1 30 -1 Paint peeling 6 4 Medium No Action Required MOTR MOTR-016 Motor 2 1 30 -1 Paint peeling 6 4 Medium No Action Required MOTR MOTR-017 Motor 2 1 30 -1 Paint peeling 6 4 Medium No Action Required SEAL SEAL-014 Seals 2 1 30 -1 6 3 Medium No Action Required SEAL SEAL-015 Seals 2 1 30 -1 6 3 Medium No Action Required SEAL SEAL-016 Seals 2 1 30 -1 6 3 Medium No Action Required ELEC ELEC-023 Lighting Panel 3 2 25 -6 7 5 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 13,875 GENR GENR-008 Adaptor for Portable Unit 3 1 20 -11 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 9,250 ELEC ELEC-024 Convenience Receptacles 3 2 20 -11 Dirty, but functional. GFI Clean around receptacles. 7 2 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 555 FIRE FIRE-004 Fire Extinguisher 2 1 15 -16 6 2 Med-Low No Action Required INST INST-041 Pressure Element 1 1 15 13
Discharge side pressure transmitter.

Range: 0-150PSI Replaced in 2020 2 6 Med-Low No Action Required LGHT LGHT-011 Lighting 1 1 20 -11 Replaced with LEDs. Adequate Lighting 6 2 Med-Low No Action Required LGHT LGHT-040 Lighting 2 1 20 -11 6 2 Med-Low No Action Required INST INST-062 Flow Element 1 1 15 13 Replaced in 2020 with McCrometer mag meter. 2 5 Low No Action Required BLDG BLDG-010 Structure 2 1 50 19 4 4 Med-Low Increased Maintenance/Operational Adjustments BLDG BLDG-011 Roof 2 1 50 19 4 4 Med-Low Increased Maintenance/Operational Adjustments INST INST-037 Flow Element 1 1 15 13
McCrometer Mag Meter
Working Pressure: 150PSI Max Replaced 2020 2 5 Low No Action Required VALV VALV-352 Butterfly Valve 1 1 25 19 Isolation butterfly valve for flow meter bypass line. 2 5 Low No Action Required VALV VALV-022 Other (Valves) 1 1 25 19 2 4 Low No Action Required VALV VALV-023 Pressure Relief Valve 1 1 25 19 2 4 Low No Action Required VALV VALV-024 D/S Isolation Valve 1 1 30 24 Isolation gate valve for zone-to-zone PRV. 2 4 Low No Action Required VALV VALV-191 Pump Control Valve 1 1 25 19 2 4 Low No Action Required VALV VALV-192 Pump Control Valve 1 1 25 19 2 4 Low No Action Required VALV VALV-193 Pump Control Valve 1 1 25 19 2 4 Low No Action Required DRNG DRNG-004 Drainage 2 1 50 19 4 3 Med-Low Increased Maintenance/Operational Adjustments FENC FENC-004 Fencing - Chain Link 2 1 40 9 4 3 Med-Low No Action Required VALV VALV-025 U/S Isolation Valve 1 1 30 24 2 4 Low No Action Required VALV VALV-123 D/S Isolation Valve 1 1 30 24 2 4 Low No Action Required VALV VALV-124 D/S Isolation Valve 1 1 30 24 2 4 Low No Action Required VALV VALV-125 D/S Isolation Valve 1 1 30 24 2 4 Low No Action Required VALV VALV-233 U/S Isolation Valve 1 1 30 24 2 4 Low No Action Required VALV VALV-234 U/S Isolation Valve 1 1 30 24 2 4 Low No Action Required VALV VALV-235 U/S Isolation Valve 1 1 30 24 Corrosion observable underneath peeling paint. 2 4 Low No Action Required WATR WATR-005 Water Service 2 1 50 19 4 3 Med-Low No Action Required ACCS ACCS-005 Access - Asphalt 2 1 50 19 4 3 Med-Low No Action Required VALV VALV-020 Other (Valves) 1 1 25 19 2 4 Low No Action Required VALV VALV-351 U/S Isolation Valve 1 1 30 24 Isolation gate valve for zone-to-zone PRV. 2 4 Low No Action Required VALV VALV-021 Air Valve 1 1 30 24 2 2 Low No Action Required VALV VALV-282 Air Valve 1 1 30 24 2 2 Low No Action Required VALV VALV-285 Air Valve 1 1 30 24 2 2 Low No Action Required INST INST-093 Pressure Element 1 1 15 13
U/S gauge for zone-to-zone PRV Heavy corrosion at
pipe connection 2 2 Low No Action Required
INST INST-094 Pressure Element 1 1 15 13
D/S gauge for zone-to-zone PRV Heavy corrosion at
pipe connection 2 2 Low No Action Required
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 927 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life Adjusted Remaining Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
ELEC ELEC-031 Motor Control Center 4 4 20 -12
Older components. Ambient temperature of room
higher than starters rated for during summer.

Common nuisance tripping. 9 9 High Replace $ 462,500
ELEC ELEC-093 Other (General Electrical) 3 3 20 -12
RTU Panel. Older components.

Rusting present on bottom of panel.

Clean corrosion and reapply paint on bottom of panel. 8 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 74,000 ELEC ELEC-030 System Service 2 1 40 8 4 9 Med-High Increased Maintenance/Operational Adjustments INST INST-029 Flow Element 4 4 15 -17
Same element as previous assessment. Label mostly
obscured. Recommend replacement. Replace flow meter with newer model. 9 5 Med-High Replace $ 10,238 PIPE PIPE-006 Yard Piping 2 1 50 18 4 9 Med-High No Action Required PIPE PIPE-055 Pump Suction Piping 2 1 50 18 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-056 Pump Discharge Piping 2 1 50 18 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-057 Pump Suction Piping 2 1 50 18 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-058 Pump Discharge Piping 2 1 50 18 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-059 Pump Suction Piping 2 1 50 18 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-060 Pump Discharge Piping 2 1 50 18 Paint peeling, corrosion on flange bolts Recoat the piping 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-136 Yard Piping 2 1 50 18 4 9 Med-High No Action Required CNTR CNTR-008 Controller 4 3 20 -12
PLC model is at End of Life. Recommend
replacement
Replace PLC with newer model. Will require
replacement of subpanel components. 8 5 Med-High Replace $ 18,500 PUMP PUMP-017 Pump 2 2 30 -2 Actual flowrate is significantly less than rate flowrate.

Continue operating pumps to failure. See
recommendations in Table 2-7 7 3 Medium No Action Required PUMP PUMP-018 Pump 2 2 30 -2 Actual flowrate is significantly less than rate flowrate.

Continue operating pumps to failure. See
recommendations in Table 2-7 7 3 Medium No Action Required PUMP PUMP-019 Pump 2 2 30 -2 Actual flowrate is significantly less than rate flowrate.

Continue operating pumps to failure. See
recommendations in Table 2-7 7 3 Medium No Action Required LGHT LGHT-014 Lighting 4 5 20 -12 Non functional during Test.

Replace bulb or repair emergency lighting as
necessary 10 2 Med-High Replace $ 27,972
LGHT LGHT-012 Lighting 3 3 20 -12
Still fluorescents. One light out. Recommend
replacement.

Replace flourescent lighting with LEDs for more
reliability and efficiency. 8 2 Medium Replace $ 27,972 LGHT LGHT-013 Lighting 3 3 20 -12
Not replaced with LEDs. Inefficient and slow to
activate.

Replace flourescent lighting with LEDs for more
reliability and efficiency. 8 2 Medium Replace $ 27,972 INST INST-030 Pressure Element 3 3 15 -17
Suction side Pressure Transmitter
Range est. 0 – 150 PSI Obsolete and difficult to
calibrate. Client plans to replace with new model. Replace gauge with newer model 8 6 Med-High Replace $ 3,885 INST INST-074 Pressure Element 3 3 15 -17
Discharge Side Pressure Transmitter
Range est. 0 – 150 PSI Obsolete and difficult to
calibrate. Client plans to replace with new model. Replace gauge with newer model 8 6 Med-High Replace $ 3,885 VALV VALV-353 Other (Valves) 3 2 25 -7
Isolation gate valve for flow meter bypass line Heavy
corrosion/leakage on bonnet. Corrosion observable
on flanges. Not included in 2015 assessment.

Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 6,475 VALV VALV-354 D/S Isolation Valve 3 2 30 -2
Isolation gate valve for flow meter Corrosion/leakage
on bonnet. Corrosion and paint peeling on
handwheel. Not included in 2015 assessment.

Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 42,734 VALV VALV-029 Air Valve 4 2 30 -2
Heavy corrosion on piping nipple from main. Heavy
corrosion on top of valve. Replace valve and piping connection to main pipe. 7 2 Medium Replace $ 18,500 HVAC HVAC-004 Roof Fan 2 1 15 1 5 5 Medium No Action Required VALV VALV-028 Pump Control Valve 3 1 25 -7 Replace valve 6 4 Medium Replace $ 31,349 VALV VALV-277 Air Valve 2 1 30 -2 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 18,500 VALV VALV-237 U/S Isolation Valve 3 1 30 -2 Corrosion, paint peeling Recoat the valve 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 VALV VALV-126 D/S Isolation Valve 2 1 30 -2 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 VALV VALV-127 D/S Isolation Valve 2 1 30 -2 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 VALV VALV-128 D/S Isolation Valve 2 1 30 -2 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 VALV VALV-236 U/S Isolation Valve 2 1 30 -2 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 VALV VALV-238 U/S Isolation Valve 2 1 30 -2 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 SEAL SEAL-017 Seals 4 2 30 -2 Evidence of leak. Replace seal 7 3 Medium Replace $ 5,550 SCDA SCDA-007 SCADA/Telemetry 2 3 10 4
New radio installed but not cut over. Recommend
finishing cutover and removal of old radio.

Finish migration of communications onto new radio
system and remove old radio from panel. 6 4 Medium Increased Maintenance/Operational Adjustments Selected Assets:

Inspection Notes: City has installed new surge anticipator valve, new backflow for building service, new Cla Val PCV, replaced below ground Influent and effluent valves. Note: These are some old non close coupled pumps.

Operator Issues:
- Old Brooks flowmeter on Sensus ActionPak
- Rosemount 1151 pressure transmitters
- Fluorescent interior lights
- Non-LED exterior lights
- Building gets hot, motor overloads nuisance trip at high ambient temps, motors themselves get very hot - Autotransformer starters for pump motors
- MCC is very old, abandoned light and switch(?) within - PLC 5 controller, panel is a mess, many modifications over the decades, UPS in separate cabinet - Needs Emergency Generator
- Needs ethernet connection to fire station
Recommended Rehab/Replacement Estimated Cost $929,894
Facility: 008 Rolling Hills Zone 2 Pump Station
Inspection Date: 6/15/2022
Inspectors: Tyler Newman, Christian Neher
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 928 of 1105 ends

MOTR MOTR-018 Motor 2 1 30 -2 6 4 Medium No Action Required MOTR MOTR-020 Motor 2 1 30 -2 6 4 Medium No Action Required MOTR MOTR-021 Motor 2 1 30 -2 6 4 Medium No Action Required SEAL SEAL-018 Seals 2 1 30 -2 6 3 Medium No Action Required SEAL SEAL-019 Seals 2 1 30 -2 6 3 Medium No Action Required ELEC ELEC-032 Lighting Panel 2 1 25 -7 6 5 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 13,875 GENR GENR-009 Adaptor for Portable Unit 2 2 20 -12
Labels sunbeaten and difficult to read.

Otherwise functional 7 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 9,250 SECR SECR-023 Alarm Systems 1 1 15 -17 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 6,475 VALV VALV-026 Other (Valves) 3 1 25 -7
Corrosion/leakage on bonnet. Corrosion and paint
peeling on handwheel.

Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 6,475 ELEC ELEC-033 Convenience Receptacles 1 1 20 -12 Good condition with GFI 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 555 FIRE FIRE-005 Fire Extinguisher 0 0 15 -17 5 2 Med-Low Inspect to Create Action Plan ELEC ELEC-094 Other (General Electrical) 2 2 20 16
DC Battery backup for RTU panel.

Old batteries, but no sign of corrosion. 4 4 Med-Low No Action Required VALV VALV-027 Pressure Relief Valve 1 1 25 21 2 4 Low No Action Required VALV VALV-294 Flow Clean Strainer 1 1 20 14 3 4 Med-Low No Action Required FENC FENC-005 Fencing - Chain Link 1 1 40 8 4 3 Med-Low No Action Required ACCS ACCS-006 Access - Asphalt 2 1 50 18 4 3 Med-Low No Action Required BLDG BLDG-012 Structure 1 1 50 36 2 4 Low No Action Required BLDG BLDG-013 Roof 1 1 50 36 2 4 Low No Action Required BLDG BLDG-043 Roll-up Door 2 2 50 36 4 3 Med-Low No Action Required VALV VALV-030 Solenoid Control 1 1 20 10 3 4 Med-Low No Action Required VALV VALV-194 Pump Control Valve 1 1 25 19 2 4 Low No Action Required VALV VALV-195 Pump Control Valve 1 1 25 19 2 4 Low No Action Required VALV VALV-196 Pump Control Valve 1 1 25 19 2 4 Low No Action Required VALV VALV-289 Solenoid Control 1 1 20 14 3 4 Med-Low No Action Required VALV VALV-291 Solenoid Control 1 1 20 14 3 4 Med-Low No Action Required VALV VALV-355 D/S Isolation Valve 1 1 30 26
Isolation gate valve for zone-to-zone PRV Isolation for pressure reducing valve. Not included in 2015
assessment. 2 4 Low No Action Required
VALV VALV-356 U/S Isolation Valve 1 1 30 26
Isolation gate valve for zone-to-zone PRV Isolation for pressure reducing valve. Not included in 2015
assessment. 2 4 Low No Action Required
WATR WATR-006 Water Service 1 1 50 46 2 3 Low No Action Required INST INST-095 Pressure Element 1 1 15 15 D/S gauge for zone-to-zone PRV 2 2 Low No Action Required INST INST-096 Pressure Element 1 1 15 15 U/S gauge for zone-to-zone PRV 2 2 Low No Action Required VALV VALV-031 Flow Control 1 1 20 10 3 2 Low No Action Required VALV VALV-290 Flow Control 1 1 20 14 3 2 Low No Action Required VALV VALV-292 Flow Control 1 1 20 14 3 2 Low No Action Required c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 929 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life Adjusted Remaining Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
ELEC ELEC-117 Motor Control Center 2 2 20 -12
Rancho Solano Golf PS Control Panel
Allen Bradley PLC-5
Input / Output List: CPU / DI / DI / DO /

AO / AI
4 Control Relays
I/O Terminal Blocks
GE MDS Orbit MCR
Esteem 192C Radio 7 9 High Schedule Long-Term Corrective Action/Rehabilitation $ 185,000 ELEC ELEC-118 Motor Control Center 2 2 20 -12 Pump Control Panel 7 9 High Schedule Long-Term Corrective Action/Rehabilitation $ 185,000 ELEC ELEC-060 Motor Control Center 4 4 20 -12
Pedestal housing circuit breakers,
motor starters and electronic overloads.

Pedestal / cabinet housing 2 VFDs: one
125HP, and one 60HP
500A Main Circuit breaker 2 conductors
per phase on line side, and with
multiple taps off load side to feed
distribution breakers:

Pump 1 Line breaker 125A
Pump 1 VFD breaker 100A
Pump 2 Line breaker 225A
Pump 2 VFD breaker 175A
Pump 3 Line breaker 225A
Pump 3 VFD breaker 175A
Pump 4 20A breaker & 12A fuses
Pump 1:
2 NEMA size 3 magnetic starters
US Motor
60HP 460V / 77A
Pump 2 & 3:
2 NEMA size 5 magnetic starters each (1
per breaker)
US Motor
125 HP 460V/ 156A
Pump 4 IEC AB starter
Sump Pump
5HP 460V/ 7.6A Panel bottom significantly corroded.

Investigate seals for leakage. Clean corrosion, reapply paint, and inspect integrity of panel bottom. Escalate to panel replacement if integrity is compromised. 9 9 High Replace $ 462,500 ELEC ELEC-059 System Service 4 4 40 8 Significant corrosion at bottom of panel. Clean corrosion and reapply paint. 8 9 High Replace $ 18,500 PIPE PIPE-160 Yard Piping 3 2 50 18 Zone-to-zone regulating piping; discharge to pond. 5 9 Med-High Increased Maintenance/Operational Adjustments ELEC ELEC-061 Lighting Panel 4 4 25 -7
Still significant corrosion on transformer. Unable to
locate lighting panel with list of loads.

Clean corrosion and reapply paint. Replacement
recommended. 9 5 Med-High Replace $ -
PIPE PIPE-007 Yard Piping 3 2 50 18 5 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-061 Pump Discharge Piping 3 2 50 18 Paint peeling, corrosion on flange bolts Recoat the piping 5 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-062 Pump Discharge Piping 3 2 50 18 Paint peeling, corrosion on flange bolts Recoat the piping 5 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-063 Pump Discharge Piping 3 2 50 18 Paint peeling, corrosion on flange bolts Recoat the piping 5 9 Med-High Increased Maintenance/Operational Adjustments INST INST-101 Level Element 3 2 15 -17
Level Transmitter Flexible conduit not fully sealed.

Wire exposed. Obsolete.

Reseal flexible conduit to protect wiring. Eventual
replacement is recommended. 7 4 Medium Replace $ 13,875 SCDA SCDA-013 SCADA/Telemetry 2 2 10 -22
New radio installed but not cut over. Recommend
finishing cutover and removal of old radio.

Finish migration of communications onto new radio
system and remove old radio from panel. 7 4 Medium No Action Required VALV VALV-357 U/S Isolation Valve 3 2 30 -2 Isolation butterfly valve for the zone-to-zone PRV. 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 INST INST-050 Level Element 4 2 15 -17 Condition seemingly unchanged.

Clean corrosion in the short term. Replacement
recommended. 7 4 Medium Replace $ 13,875
VALV VALV-032 Pressure Relief Valve 3 2 25 -7 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 6,475 VALV VALV-091 Check Valve 3 2 25 -7 Replace valve 7 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 4,280 VALV VALV-092 Check Valve 3 2 25 -7 Replace valve 7 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 4,280 VALV VALV-093 Check Valve 3 2 25 -7 Replace valve 7 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 3,097 VALV VALV-129 D/S Isolation Valve 3 2 30 -2
Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 29,903 VALV VALV-130 D/S Isolation Valve 3 2 30 -2
Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 29,903 VALV VALV-131 D/S Isolation Valve 3 2 30 -2
Repair/rebuild valve, replace corroded parts, replace
valve as necessary. 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 Inspection Notes:

Operator Issues:

Recommended Rehab/Replacement Estimated Cost $1,013,488 Selected Assets:

Facility: 114 Rancho Solano Golf Course Pump Station
Inspection Date: 6/21/2022
Inspectors: Tyler Newman, Christian Neher
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 930 of 1105 ends

TANK TANK-003 Bladder Tank 2 1 30 -2 6 5 Medium Schedule Long-Term Corrective Action/Rehabilitation $ - PUMP PUMP-020 Pump 3 2 30 -2 Heavy corrosion on pump frame.

Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess the isolation valves to be sure there is no recirculation 7 4 Medium Increased Maintenance/Operational Adjustments PUMP PUMP-021 Pump 3 2 30 -2 Heavy corrosion on pump frame.

Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess the isolation valves to be sure there is no recirculation 7 4 Medium Increased Maintenance/Operational Adjustments PUMP PUMP-022 Pump 3 2 30 -2 Heavy corrosion on pump frame.

Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess the isolation valves to be sure there is no recirculation 7 4 Medium Increased Maintenance/Operational Adjustments SEAL SEAL-020 Seals 3 2 30 -2 Recoat the seal, replace bolts 7 3 Medium Increased Maintenance/Operational Adjustments SEAL SEAL-021 Seals 3 2 30 -2 Recoat the seal, replace bolts 7 3 Medium Increased Maintenance/Operational Adjustments SEAL SEAL-022 Seals 3 2 30 -2 Recoat the seal, replace bolts 7 3 Medium Increased Maintenance/Operational Adjustments LGHT LGHT-025 Lighting 1 1 20 -12 Replaced with LEDs 6 2 Med-Low No Action Required PUMP PUMP-061 Sump Pump 2 2 30 -2 7 2 Medium No Action Required ELEC ELEC-062 Convenience Receptacles 2 2 20 -12
Room receptacles in good shape. Panel in VFD cabinet
is no longer near 480 lugs, but still close to
transformer. Recommend safety cover for transformer. 7 2 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 555 BLDG BLDG-014 Structure 3 1 50 18 4 4 Med-Low Increased Maintenance/Operational Adjustments FILT FILT-001 Filters 2 1 40 24 3 5 Med-Low No Action Required CNTR CNTR-014 Controller 4 3 20 -12 PLC model is at End of Life. Recommend replacement Replace PLC with newer model. Will require
replacement of subpanel components. 8 5 Med-High Replace $ 18,500 WATR WATR-007 Water Service 1 1 50 18 4 3 Med-Low No Action Required ACCS ACCS-007 Access - Asphalt 1 1 50 18 4 3 Med-Low No Action Required BLDG BLDG-015 Roof 1 1 50 35 3 4 Med-Low No Action Required MOTR MOTR-022 Motor 1 1 30 17 3 4 Med-Low No Action Required MOTR MOTR-023 Motor 1 1 30 17 3 4 Med-Low No Action Required MOTR MOTR-024 Motor 1 1 30 17 3 4 Med-Low No Action Required c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 931 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life
Adjusted Remaining
Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
ELEC ELEC-114 Motor Control Center 3 3 20 -14 Old PLC cabinet. Replacement in progress.

Continue installation of new PLC cabinet, and remove
this panel when complete. 8 9 High No Action Required
ELEC ELEC-056 Motor Control Center 3 3 20 -14
Replacement of MCC was in progress during visit.

New MCC present, but inactive.

Complete installation of new MCC and remove this
MCC 8 9 High No Action Required
SCDA SCDA-012 SCADA/Telemetry 4 3 10 -24
New radio installed but not cut over. Recommend
finishing cutover and removal of old radio.

Finish migration of communications onto new radio
system and remove old radio from panel. 8 4 Medium No Action Required ELEC ELEC-055 System Service 2 2 40 6 5 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-008 Yard Piping 2 1 50 16 4 9 Med-High No Action Required PIPE PIPE-064 Pump Discharge Piping 2 1 50 16 Paint peeling, corrosion on flange bolts 4 9 Med-High No Action Required PIPE PIPE-065 Pump Discharge Piping 2 1 50 16 Paint peeling, corrosion on flange bolts 4 9 Med-High No Action Required PIPE PIPE-066 Pump Discharge Piping 2 1 50 16 Paint peeling, corrosion on flange bolts 4 9 Med-High No Action Required PIPE PIPE-067 Pump Discharge Piping 2 1 50 16 Paint peeling, corrosion on flange bolts 4 9 Med-High No Action Required CNTR CNTR-013 Controller 4 3 20 -14 PLC model is at End of Life. Recommend replacement Replacement of PLC with newer model in progress.

Will require replacement of subpanel components. 8 5 Med-High No Action Required ELEC ELEC-113 Motor Control Center 1 1 20 20
New MCC. Still being installed and not currently
operational. 2 9 Med-Low No Action Required
ELEC ELEC-116 Motor Control Center 1 1 20 20 New PLC panel. Installation in progress. 2 9 Med-Low No Action Required LGHT LGHT-024 Lighting 3 3 20 -14
Still fluorescent. Recommend replacement with LEDs
for improved performance and efficiency.

Replace flourescent lighting with LEDs for more
reliability and efficiency. 8 2 Medium Replace $ 26,973 ELEC ELEC-057 Lighting Panel 4 2 25 -9
Older lighting panel. No load list. Assuming
unchanged from previous visit. 7 5 Medium Schedule Long-Term Corrective Action/Rehabilitation $ - HVAC HVAC-005 Roof Fan 1 1 15 0 6 5 Medium No Action Required VALV VALV-094 Check Valve 2 1 25 -2 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 3,097 VALV VALV-095 Check Valve 2 1 25 -2 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 3,097 VALV VALV-096 Check Valve 2 1 25 -2 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 3,097 VALV VALV-097 Check Valve 2 1 25 -2 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 3,097 VALV VALV-034 Air Valve 2 1 30 -4 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 18,500 VALV VALV-132 D/S Isolation Valve 2 1 30 -4 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 VALV VALV-133 D/S Isolation Valve 2 1 30 -4 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 VALV VALV-134 D/S Isolation Valve 2 1 30 -4 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 VALV VALV-135 D/S Isolation Valve 2 1 30 -4 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,872 MOTR MOTR-028 Motor 2 1 30 -4 6 4 Medium No Action Required PUMP PUMP-023 Pump 2 2 30 -4
Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess
the isolation valves to be sure there is no
recirculation. 7 4 Medium Increased Maintenance/Operational Adjustments PUMP PUMP-024 Pump 2 2 30 -4
Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess
the isolation valves to be sure there is no
recirculation. 7 4 Medium Increased Maintenance/Operational Adjustments PUMP PUMP-025 Pump 2 2 30 -4
Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess
the isolation valves to be sure there is no
recirculation. 7 4 Medium Increased Maintenance/Operational Adjustments PUMP PUMP-026 Pump 2 2 30 -4
Continue operating pump to failure; assess the pump
for wear on the impellers and rotating parts; assess
the isolation valves to be sure there is no
recirculation. 7 4 Medium Increased Maintenance/Operational Adjustments INST INST-048 Level Element 2 1 15 -19
Did not view instrument directly, but reportedly in
good condition. 6 4 Medium No Action Required
ELEC ELEC-058 Convenience Receptacles 3 2 20 -14
Only convenience receptacle is located in old PLC
panel. 7 2 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 555 INST INST-100 Pressure Element 2 1 15 13
Small scratch on front, but newer model and recently
installed. 3 6 Med-Low No Action Required
BLDG BLDG-017 Roof 1 1 50 16 4 4 Med-Low Increased Maintenance/Operational Adjustments FIRE FIRE-006 Fire Extinguisher 0 0 15 -19 5 2 Med-Low Inspect to Create Action Plan MOTR MOTR-025 Motor 2 1 30 3 Motor reconditioned in 2020 5 4 Medium No Action Required MOTR MOTR-026 Motor 2 1 30 3 Motor reconditioned and bearings replaced in 2020 5 4 Medium No Action Required MOTR MOTR-027 Motor 2 1 30 3 Motor reconditioned in 2020 5 4 Medium No Action Required SEAL SEAL-023 Seals 2 1 30 3 5 3 Med-Low No Action Required SEAL SEAL-024 Seals 2 1 30 3 5 3 Med-Low No Action Required SEAL SEAL-025 Seals 2 1 30 3 5 3 Med-Low No Action Required Selected Assets:
$133,903
Inspection Notes: All pumps have been rebuilt. New 14” effluent butterfly isolation valve and a new flow meter. 3 x 40HP, and 1 x 15hp (City indicated the 15hp pump is a waste of space) Operator Issues:

Recommended Rehab/Replacement Estimated Cost
Facility: 113 Rancho Solano Raw Water Pump Station
Inspection Date: 6/21/2022
Inspectors: Tyler Newman, Christian Neher
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 932 of 1105 ends

SEAL SEAL-026 Seals 2 1 30 3 5 3 Med-Low No Action Required BLDG BLDG-016 Structure 1 1 50 16 4 4 Med-Low Increased Maintenance/Operational Adjustments INST INST-049 Flow Element 1 1 15 13 2 5 Low No Action Required INST INST-063 Flow Element 1 1 15 9 3 5 Med-Low No Action Required CNTR CNTR-020 Controller 1 1 20 20 Installation still in progress. 2 5 Low No Action Required ELEC ELEC-115 Lighting Panel 1 1 25 25
New Lighting Panel. Still being installed and not
currently operational. 2 5 Low No Action Required
FENC FENC-006 Fencing - Chain Link 2 1 40 6 4 3 Med-Low No Action Required ACCS ACCS-008 Access - Asphalt 2 1 50 16 4 3 Med-Low No Action Required SCDA SCDA-020 SCADA/Telemetry 1 1 10 10
New radio located in new plc panel. Installation still
in progress.

Finish migration of communications onto new radio
system. 2 4 Low No Action Required
VALV VALV-033 Other (Valves) 1 1 25 19 2 4 Low No Action Required c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 933 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life
Adjusted Remaining
Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
ELEC ELEC-103 Motor Control Center 4 3 20 5
Pump 1 VFD Enclosure Model is at end of supported
life. Replace VFD with newer, currently supported model. 7 9 High Replace $ 185,000 ELEC ELEC-104 Motor Control Center 2 1 20 5
Rancho Solano Z3 PS PLC Panel
Allen Bradley 1756-PA75B
5 AC Input Modules
2 Relay Output Modules
3 Analog Input Modules
1 Analog Output Modules
EthernetIP Module
IO Terminal Blocks
Ethernet Switch
Fiber Patch Panel PLC is much newer than other sites. 4 9 Med-High Increased Maintenance/Operational Adjustments ELEC ELEC-050 System Service 2 1 40 27 3 9 Medium No Action Required ELEC ELEC-051 Motor Control Center 2 1 20 7 4 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-009 Yard Piping 2 1 50 37 3 9 Medium No Action Required PIPE PIPE-068 Pump Suction Piping 2 1 50 37 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-069 Pump Discharge Piping 2 1 50 37 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-070 Pump Suction Piping 2 1 50 37 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-071 Pump Discharge Piping 2 1 50 37 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-072 Pump Suction Piping 2 1 50 37 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-073 Pump Discharge Piping 2 1 50 37 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-149 Yard Piping 2 1 50 37
Common suction piping inside building, and thru wall.

Not included in 2015 assessment. 3 9 Medium No Action Required SCDA SCDA-011 SCADA/Telemetry 2 1 10 -3 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 83,250 ELEC ELEC-052 Surge Protector 2 2 20 7 5 6 Medium Increased Maintenance/Operational Adjustments HVAC HVAC-014 Roof Fan 2 1 15 2 4 5 Med-Low No Action Required HVAC HVAC-015 Roof Fan 2 1 15 2 4 5 Med-Low No Action Required INST INST-045 Flow Element 2 1 15 2 4 5 Med-Low No Action Required ELEC ELEC-105 Other (General Electrical) 1 1 20 5 Local shutoff for Pumps 1, 2, & 3. 4 5 Med-Low Increased Maintenance/Operational Adjustments CNTR CNTR-012 Controller 2 1 20 7 4 5 Med-Low Increased Maintenance/Operational Adjustments ELEC ELEC-053 Lighting Panel 2 1 25 12 3 5 Med-Low No Action Required PUMP PUMP-027 Pump 2 3 30 17
Actual flowrate is less than rated flowrate.

Pump/motor recently rebuilt.

Assess the pumps for wear on the impellers and
rotating parts; assess the isolation valves to be sure
there is no recirculation.

See recommendations in Table 2-7 5 3 Med-Low Increased Maintenance/Operational Adjustments PUMP PUMP-028 Pump 2 3 30 17
Actual flowrate is less than rated flowrate.

Pump/motor recently rebuilt.

Assess the pumps for wear on the impellers and
rotating parts; assess the isolation valves to be sure
there is no recirculation.

See recommendations in Table 2-7 5 3 Med-Low Increased Maintenance/Operational Adjustments PUMP PUMP-029 Pump 2 3 30 17 Actual flowrate is less than rated flowrate.

Assess the pumps for wear on the impellers and
rotating parts; assess the isolation valves to be sure
there is no recirculation.

See recommendations in Table 2-7 5 3 Med-Low Increased Maintenance/Operational Adjustments ELEC ELEC-054 Convenience Receptacles 2 2 20 7 5 2 Med-Low Increased Maintenance/Operational Adjustments BLDG BLDG-018 Structure 2 1 50 37 3 4 Med-Low No Action Required BLDG BLDG-019 Roof 2 1 50 37 3 4 Med-Low No Action Required VALV VALV-136 D/S Isolation Valve 2 1 30 17 3 4 Med-Low No Action Required VALV VALV-137 D/S Isolation Valve 2 1 30 17 3 4 Med-Low No Action Required VALV VALV-138 D/S Isolation Valve 2 1 30 17 3 4 Med-Low No Action Required VALV VALV-197 Pump Control Valve 2 1 25 15 3 4 Med-Low No Action Required VALV VALV-198 Pump Control Valve 2 1 25 15 3 4 Med-Low No Action Required VALV VALV-199 Pump Control Valve 2 1 25 15 3 4 Med-Low No Action Required VALV VALV-239 U/S Isolation Valve 2 1 30 20 3 4 Med-Low No Action Required VALV VALV-240 U/S Isolation Valve 2 1 30 20 3 4 Med-Low No Action Required VALV VALV-241 U/S Isolation Valve 2 1 30 20 3 4 Med-Low No Action Required BLDG BLDG-044 Roll-up Door 2 2 50 37 Roll up door - not included in 2015 assessment. 4 3 Med-Low No Action Required MOTR MOTR-029 Motor 2 1 30 17 3 4 Med-Low No Action Required MOTR MOTR-030 Motor 2 1 30 17 3 4 Med-Low No Action Required MOTR MOTR-031 Motor 2 1 30 17 3 4 Med-Low No Action Required FIRE FIRE-008 Fire Extinguisher 1 1 15 2 4 2 Med-Low No Action Required INST INST-046 Pressure Element 2 1 15 2 4 2 Med-Low No Action Required Selected Assets:

Inspection Notes: Pumps/motor 1 and 2 have been rebuilt. Newer Cla Val PCV.

Operator Issues:

Recommended Rehab/Replacement Estimated Cost $268,250
Facility: 012 Rancho Solano Zone 3 Pump Station
Inspection Date: 6/15/2022
Inspectors: Tyler Newman, Christian Neher
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 934 of 1105 ends

INST INST-047 Pressure Element 2 1 15 2
Pump 1 Pressure Switch.

PSH-781
Range 9-300 PSI 4 2 Med-Low No Action Required
INST INST-075 Pressure Element 2 1 15 2
Pump 2 Pressure Switch.

PSH-782
Range 9-300 PSI 4 2 Med-Low No Action Required
INST INST-076 Pressure Element 2 1 15 2
Pump 3 Pressure Switch.

PSH-783
Range 9-300 PSI 4 2 Med-Low No Action Required
INST INST-077 Pressure Element 2 1 15 2 4 2 Med-Low No Action Required INST INST-078 Pressure Element 2 1 15 2 4 2 Med-Low No Action Required INST INST-079 Pressure Element 2 1 15 2 4 2 Med-Low No Action Required LGHT LGHT-022 Lighting 1 1 20 7 Replaced with LEDs 4 2 Med-Low No Action Required VALV VALV-086 Air Valve 2 1 30 17 3 2 Low No Action Required VALV VALV-085 Air Valve 2 1 30 17 3 2 Low No Action Required VALV VALV-084 Air Valve 2 1 30 17 3 2 Low No Action Required WATR WATR-008 Water Service 2 1 50 37 3 3 Low No Action Required FIRE FIRE-007 Automatic Sprinkler 2 1 30 17 3 3 Low No Action Required SEAL SEAL-027 Seals 2 1 30 17 3 3 Low No Action Required SEAL SEAL-028 Seals 2 1 30 17 3 3 Low No Action Required SEAL SEAL-029 Seals 2 1 30 17 3 3 Low No Action Required c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 935 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life
Adjusted Remaining
Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
ELEC ELEC-069 Motor Control Center 3 3 20 -13 8 9 High Schedule Long-Term Corrective Action/Rehabilitation $ 462,500 INST INST-054 Flow Element 4 4 15 -18 Model is at end of life. Recommend replacement. Replace flow meter with newer model. 9 5 Med-High Replace $ 11,215 ELEC ELEC-068 System Service 3 2 40 7 5 9 Med-High Increased Maintenance/Operational Adjustments PIPE PIPE-074 Pump Suction Piping 2 1 50 17 Paint peeling, corrosion on flange bolts 4 9 Med-High No Action Required PIPE PIPE-075 Pump Discharge Piping 2 1 50 17 Paint peeling, corrosion on flange bolts 4 9 Med-High No Action Required PIPE PIPE-076 Pump Suction Piping 2 1 50 17 Paint peeling, corrosion on flange bolts 4 9 Med-High No Action Required PIPE PIPE-077 Pump Discharge Piping 2 1 50 17 Paint peeling, corrosion on flange bolts 4 9 Med-High No Action Required PIPE PIPE-137 Yard Piping 2 1 50 17 4 9 Med-High No Action Required PIPE PIPE-143 Yard Piping 2 1 50 17 4 9 Med-High No Action Required GENR GENR-013 Adaptor for Portable Unit 4 3 20 -13 8 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 9,250 LGHT LGHT-030 Lighting 3 5 20 -13 Non functional during test Replace bulb or repair emergency lighting as necessary 10 2 Med-High Schedule Near-Term Corrective Action/Rehabilitation $ 22,200 INST INST-055 Pressure Element 3 3 15 -18
Discharge side Pressure Transmitter
Range 0-150PSI
300 PSI Max Obsolete and difficult to calibrate. Client plans to replace with new model. Replace gauge with newer model 8 6 Med-High Replace $ 3,885 ELEC ELEC-109 Other (General Electrical) 2 2 20 -13 Emergency transformer. Never been used. 7 5 Medium Schedule Long-Term Corrective Action/Rehabilitation $ - ELEC ELEC-110 Other (General Electrical) 2 3 20 -13
Manual Transfer Switch Juntion box specifically for
neutral lines. 8 5 Med-High Schedule Long-Term Corrective Action/Rehabilitation $ 74,000 VALV VALV-323 D/S Isolation Valve 2 2 30 -3
D/S isolation valve for flow meter, not included in
2015 assessment. Paint peeling, corrosion observed. 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 29,903 VALV VALV-324 U/S Isolation Valve 2 2 30 -3
D/S isolation valve for flow meter, not included in
2015 assessment. Paint peeling, corrosion observed. 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 29,903 INST INST-053 Level Element 3 2 15 -18
Readout available at station. Unable to view
transmitter at reservoir. 7 4 Medium Increased Maintenance/Operational Adjustments SCDA SCDA-015 SCADA/Telemetry 2 1 10 -23
Fiber connects to Zone 5 station to transmit out to
SCADA. 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 83,250 VALV VALV-036 U/S Isolation Valve 2 1 30 -3 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 29,903 VALV VALV-040 Air Valve 2 2 30 -3 7 2 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,500 VALV VALV-041 Air Valve 2 2 30 -3 7 2 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,500 VALV VALV-139 D/S Isolation Valve 2 1 30 -3 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 9,864 VALV VALV-140 D/S Isolation Valve 2 1 30 -3 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 9,864 VALV VALV-243 U/S Isolation Valve 2 1 30 -3 6 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 9,864 MOTR MOTR-033 Motor 2 1 30 -3 6 4 Medium No Action Required CNTR CNTR-016 Controller 2 2 20 -13 7 5 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 18,500 ELEC ELEC-070 Lighting Panel 2 1 25 -8 6 5 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 13,875 LGHT LGHT-031 Lighting 3 1 20 -13 Performance unconfirmed. 6 2 Med-Low Increased Maintenance/Operational Adjustments LGHT LGHT-029 Lighting 2 2 20 -13 7 2 Medium No Action Required ELEC ELEC-071 Convenience Receptacles 2 1 20 -13 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 555 SCDA SCDA-018 SCADA/Telemetry - 0 10 -18 5 4 Medium Inspect to Create Action Plan VALV VALV-037 D/S Isolation Valve - 0 30 -3
Valve below grade beneath concrete slab. Did not
observe. 5 4 Medium Inspect to Create Action Plan
HVAC HVAC-007 Roof Fan 1 1 15 4 4 5 Med-Low No Action Required FIRE FIRE-009 Fire Extinguisher - 0 15 -18 5 2 Med-Low Inspect to Create Action Plan MOTR MOTR-032 Motor 2 1 30 10 4 4 Med-Low No Action Required VALV VALV-242 U/S Isolation Valve 2 1 30 26 3 4 Med-Low No Action Required FENC FENC-007 Other (Fencing) 1 1 40 7 4 3 Med-Low No Action Required VALV VALV-039 Pressure Relief Valve 1 1 25 21 2 4 Low No Action Required ACCS ACCS-010 Concrete 1 1 50 17 4 3 Med-Low No Action Required VALV VALV-201 Pump Control Valve 2 1 25 21 3 4 Med-Low No Action Required GENR GENR-016 Adaptor for Portable Unit 2 2 20 9
480V to 240V stepdown transformer for portable
generator, not included in 2015 assessment. 4 3 Med-Low No Action Required GENR GENR-017 Adaptor for Portable Unit 2 2 20 9
Adaptor for portable unit, not included in 2015
assessment. 4 3 Med-Low No Action Required
PUMP PUMP-030 Pump 2 5 30 10 No flow/TDH ratings on nameplate Replace. See recommendations in Table 2-7 8 3 Medium Replace $ 27,750 PUMP PUMP-031 Pump 2 5 30 10 No flow/TDH ratings on nameplate Replace. See recommendations in Table 2-7 8 3 Medium Replace $ 27,750 SEAL SEAL-030 Seals 2 1 30 10 4 3 Med-Low No Action Required SEAL SEAL-031 Seals 2 1 30 10 4 3 Med-Low No Action Required Facility: 016 Rancho Solano Zone 4 Pump Station (Hydro) Inspection Date: 6/21/2022
Inspectors: Tyler Newman, Christian Neher
Inspection Notes: New Cla Val PCV and PRV. Pump #2 was rebuilt and pump #1 has a new influent valve.

Operator Issues:
- Non-LED outdoor lighting
- Indoor fluorescent lights
- Old MCC
- PLC panel is a mess
- Ongoing pump hydraulic issue investigation that has been the cause of modifying pump control panels (this is a biggie) - Main Breaker replaced once
Recommended Rehab/Replacement Estimated Cost $911,033
Selected Assets:
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 936 of 1105 ends

VALV VALV-038 U/S Isolation Valve - 0 30 15
Valve below grade beneath concrete slab. Did not
observe. 2 4 Low Inspect to Create Action Plan
BLDG BLDG-020 Structure 1 1 50 39 2 4 Low No Action Required BLDG BLDG-021 Roof 1 1 50 39 2 4 Low No Action Required VALV VALV-200 Pump Control Valve 1 1 25 21 2 4 Low No Action Required COUP COUP-058 D/S Coupling 2 1 20 9 3 3 Low No Action Required COUP COUP-057 D/S Coupling 1 1 20 9 3 3 Low No Action Required INST INST-095 Pressure Element 2 1 15 15 D/S gauge for zone-to-zone PRV 2 2 Low No Action Required INST INST-096 Pressure Element 2 1 15 15 U/S gauge for zone-to-zone PRV 2 2 Low No Action Required INST INST-097 Pressure Element 1 1 15 15
New Pump 3 Discharge Pressure Transmitter
Installation still in progress Complete installation 2 2 Low No Action Required c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 937 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life
Adjusted Remaining
Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/Repai
r Cost
ELEC ELEC-077 System Service 1 1 40 37 2 9 Med-Low No Action Required SCDA SCDA-017 SCADA/Telemetry 1 1 10 7
New radio installed 2019
OIT reports to SCADA. 2 4 Low No Action Required
PIPE PIPE-138 Yard Piping 2 1 50 22 3 9 Medium No Action Required ELEC ELEC-084 Other (General Electrical) 1 1 20 17 Automatic Transfer Switch 2 6 Med-Low No Action Required PIPE PIPE-011 Yard Piping 2 1 50 48 3 9 Medium No Action Required PIPE PIPE-012 Yard Piping 2 1 50 22 3 9 Medium No Action Required PIPE PIPE-078 Pump Suction Piping 2 1 50 48 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-079 Pump Discharge Piping 2 1 50 48 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-080 Pump Suction Piping 2 1 50 48 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-081 Pump Discharge Piping 2 1 50 48 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-082 Pump Suction Piping 2 1 50 48 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-083 Pump Discharge Piping 2 1 50 48 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-146 Yard Piping 2 2 50 23 Common pump suction piping. 4 9 Med-High No Action Required PIPE PIPE-147 Yard Piping 2 2 50 23 Bladder tank fill line. 4 9 Med-High No Action Required PIPE PIPE-148 Yard Piping 2 2 50 48 Pump suction manifold. 4 9 Med-High No Action Required ELEC ELEC-079 Surge Protector 1 1 20 17 2 6 Med-Low No Action Required ELEC ELEC-078 Motor Control Center 1 1 20 17 2 9 Med-Low No Action Required LGHT LGHT-038 Lighting 1 1 20 17 2 2 Low No Action Required INST INST-059 Pressure Element 3 2 15 -13
Suction side pressure transmitter
0-300 PSI
300 PSI Max Obsolete and difficult to calibrate. Client plans to replace with new model. Replace gauge with newer model 7 6 Med-High Replace $ 3,885 INST INST-060 Pressure Element 1 1 15 -13
Discharge side pressure transmitter
0-300 PSI
300 PSI Max Obsolete and difficult to calibrate. Client plans to replace with new model. Replace gauge with newer model 6 6 Medium Replace $ 3,885 VALV VALV-325 Other (Valves) 2 2 25 -2
1" ball valve used for isolation on the bladder tank
inlet/outlet piping. Not included in 2015 assessment. 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 6,475 CNTR CNTR-018 Controller 1 1 20 17 2 5 Low No Action Required ELEC GENR-001 Onsite Generator 2 2 25 -3 7 4 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 92,500 ELEC ELEC-080 Lighting Panel 1 1 25 22 2 5 Low No Action Required LGHT LGHT-035 Lighting 1 1 20 17 2 2 Low No Action Required COUP COUP-060 Reducer 1 1 20 -8 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 463 SCDA SCDA-019 SCADA/Telemetry 1 1 10 7
Fiber optic access. Z4 uses this to connect to Z5
before transmitting to SCADA. 2 4 Low No Action Required INST INST-058 Flow Element 1 1 15 15
McCrometer Mag Meter
Working Pressure: 150PSI Max Replaced 2022 2 5 Low No Action Required TANK TANK-004 Bladder Tank 2 1 30 27 3 5 Med-Low No Action Required PUMP PUMP-032 Pump 2 3 30 28
Continue operating pump to failure; assess the
pump for wear on the impellers and rotating parts;
assess the isolation valves to be sure there is no
recirculation 5 3 Med-Low Increased Maintenance/Operational Adjustments PUMP PUMP-033 Pump 2 3 30 28
Continue operating pump to failure; assess the
pump for wear on the impellers and rotating parts;
assess the isolation valves to be sure there is no
recirculation 5 3 Med-Low Increased Maintenance/Operational Adjustments PUMP PUMP-034 Pump 2 3 30 28
Continue operating pump to failure; assess the
pump for wear on the impellers and rotating parts;
assess the isolation valves to be sure there is no
recirculation 5 3 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-042 Check Valve 2 1 25 23 3 4 Med-Low No Action Required VALV VALV-141 D/S Isolation Valve 2 1 30 28 3 4 Med-Low No Action Required VALV VALV-142 D/S Isolation Valve 2 1 30 28 3 4 Med-Low No Action Required VALV VALV-143 D/S Isolation Valve 2 1 30 28 3 4 Med-Low No Action Required VALV VALV-244 U/S Isolation Valve 2 1 30 28 3 4 Med-Low No Action Required VALV VALV-245 U/S Isolation Valve 2 1 30 28 3 4 Med-Low No Action Required VALV VALV-246 U/S Isolation Valve 2 1 30 28 3 4 Med-Low No Action Required BLDG BLDG-023 Other (Building) 2 1 50 22 3 4 Med-Low No Action Required VALV VALV-043 U/S Isolation Valve 2 1 30 28 3 4 Med-Low No Action Required VALV VALV-273 D/S Isolation Valve 2 1 30 28 3 4 Med-Low No Action Required MOTR MOTR-034 Motor 2 1 30 28 3 4 Med-Low No Action Required Selected Assets:

Facility: 018 Rancho Solano Zone 5 Pump Station (Hydro) Inspection Date: 6/21/2022
Inspectors: Tyler Newman, Christian Neher
Inspection Notes: New Grundfos vertical turbine pumps and whole new skid (5hp and 53GPM). New Z4 to Z5 check valve, new OS&Y gate valves, and a new flow meter; all components (electrical, controls, telemetry, etc.) were replaced with the new pump station in 2019.

Operator Issues:

Recommended Rehab/Replacement Estimated Cost $107,208
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 938 of 1105 ends

MOTR MOTR-035 Motor 2 1 30 28 3 4 Med-Low No Action Required MOTR MOTR-036 Motor 2 1 30 28 3 4 Med-Low No Action Required BLDG BLDG-022 Roof 1 1 50 22 3 4 Med-Low No Action Required FENC FENC-008 Fencing - Chain Link 1 1 40 12 4 3 Med-Low No Action Required VALV VALV-045 Air Valve 2 1 30 28 3 2 Low No Action Required VALV VALV-098 Check Valve 2 1 25 23 3 3 Low No Action Required VALV VALV-099 Check Valve 2 1 25 23 3 3 Low No Action Required VALV VALV-100 Check Valve 2 1 25 23 3 3 Low No Action Required ACCS ACCS-011 Access - Asphalt 1 1 50 22 3 3 Low No Action Required COUP COUP-059 Reducer 1 1 20 11 3 3 Low No Action Required INST INST-097 Pressure Element 1 1 15 15
New Pump 3 Discharge Pressure Transmitter
Installation still in progress Complete installation 2 2 Low No Action Required INST INST-099 Transmitter 1 1 15 13 Valve Switch Reports Open/Close Status to PLC 2 2 Low No Action Required c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 939 of 1105 ends

Asset Class AssetID Asset Subclass Condition Performance Industry Standard
Remaining Life
Adjusted Remaining
Life Inspection Notes Recommended Improvements LOF Score COF Score Risk Level Final Action Plan Rehabilitation/
Repair Cost
INST INST-052 Pressure Element 1 1 15 -5 Suction Side Pressure Transmitter 6 6 Medium No Action Required INST INST-081 Pressure Element 3 2 15 -5 Discharge Side Pressure Transmitter 7 6 Med-High Increased Maintenance/Operational Adjustments CNTR CNTR-015 Controller 4 3 20 0 PLC model is at End of Life. Recommend replacement Replace PLC with newer model. Will require
replacement of subpanel components. 8 5 Med-High Replace $ 18,500 PIPE PIPE-014 Yard Piping 2 1 50 30 3 9 Medium No Action Required PIPE PIPE-016 Yard Piping 2 1 50 30 3 9 Medium No Action Required PIPE PIPE-090 Pump Suction Piping 2 1 50 30 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-091 Pump Discharge Piping 2 1 50 30 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-092 Pump Suction Piping 2 1 50 30 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-093 Pump Discharge Piping 2 1 50 30 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-094 Pump Suction Piping 2 1 50 30 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-095 Pump Discharge Piping 2 1 50 30 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-096 Pump Suction Piping 2 1 50 30 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required PIPE PIPE-097 Pump Discharge Piping 2 1 50 30 Paint peeling, corrosion on flange bolts 3 9 Medium No Action Required ELEC ELEC-065 Surge Protector 2 1 20 0 6 6 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 3,700 ELEC ELEC-063 System Service 2 1 40 20 3 9 Medium No Action Required ELEC ELEC-064 Motor Control Center 2 2 20 0
Previously installed Pump VFDs have been removed
and replaces with CS Starters
PLC Panel Several older components Replace power supply with newer model. 7 9 High Replace $ 462,500 PIPE PIPE-150 Yard Piping 2 2 50 30
Zone-to-zone regulating piping; discharge to ground,
not included in 2015 assessment. 4 9 Med-High No Action Required PIPE PIPE-151 Yard Piping 2 2 50 30
Tank inlet/outlet piping, not included in 2015
assessment 4 9 Med-High No Action Required
LGHT LGHT-026 Lighting 1 1 20 0 6 2 Med-Low No Action Required LGHT LGHT-027 Lighting 2 2 20 0 7 2 Medium No Action Required LGHT LGHT-028 Lighting 3 2 20 0 7 2 Medium Increased Maintenance/Operational Adjustments ELEC ELEC-067 Convenience Receptacles 2 1 20 0 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 555 COUP COUP-001 Other (Coupling) 2 1 20 0 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 COUP COUP-008 D/S Coupling 2 1 20 0 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 COUP COUP-009 D/S Coupling 2 1 20 0 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 COUP COUP-010 D/S Coupling 2 1 20 0 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 COUP COUP-011 D/S Coupling 2 1 20 0 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 COUP COUP-012 D/S Coupling 2 1 20 0 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 COUP COUP-037 U/S Coupling 2 1 20 0 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 COUP COUP-038 U/S Coupling 2 1 20 0 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 COUP COUP-039 U/S Coupling 2 1 20 0 6 3 Medium Schedule Long-Term Corrective Action/Rehabilitation $ 606 HVAC HVAC-008 Roof Fan 2 1 15 -5 6 5 Medium No Action Required COMP COMP-004 Air Compressor 2 1 20 0 6 2 Med-Low Schedule Long-Term Corrective Action/Rehabilitation $ 2,775 SCDA SCDA-014 SCADA/Telemetry 3 2 10 -10
Replace OIT with newer model.

Finish migration of communications onto new radio
system and remove old radio from panel. 7 4 Medium Replace $ 83,250 MOTR MOTR-040 Motor 2 1 30 10 4 4 Med-Low No Action Required MOTR MOTR-041 Motor 2 1 30 10 4 4 Med-Low No Action Required MOTR MOTR-042 Motor 2 1 30 10 4 4 Med-Low No Action Required MOTR MOTR-043 Motor 2 1 30 10 4 4 Med-Low No Action Required ELEC ELEC-106 Other (General Electrical) 2 1 20 14 3 5 Med-Low No Action Required ELEC ELEC-107 Other (General Electrical) 2 1 20 16 DC battery backup for PLC Panel 3 5 Med-Low No Action Required FIRE FIRE-010 Fire Extinguisher - 0 15 -5 5 2 Med-Low Inspect to Create Action Plan ELEC ELEC-066 Lighting Panel 2 1 25 5 4 5 Med-Low Increased Maintenance/Operational Adjustments INST INST-051 Flow Element 1 2 15 11
ABB Limited
WaterMaster 3 5 Med-Low No Action Required
TANK TANK-006 Hydropneumatic Tank 2 1 30 10 4 5 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-049 U/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-052 Pressure Relief Valve 2 1 25 5 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-053 Pressure Relief Valve 2 1 25 5 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-147 D/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-148 D/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-149 D/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments Selected Assets:

Inspection Notes: Hydro tank rehabilitated, new flow meter installed, Pump 3 has been rebuilt.

Operator Issues:
- Rosemount 1151 pressure transmitters on suction and discharge - PLC 5 Controller
- Non-LED outdoor lighting
- Panelview 600 HMI
- Emergency generator needs load bank
- Hows the hillside behind it?
- Safer Access (vehicle Pull in)
Recommended Rehab/Replacement Estimated Cost $736,138
Facility: 015 Sanctuary Zone 3 Pump Station
Inspection Date: 6/15/2022
Inspectors: Tyler Newman, Christian Neher
c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 940 of 1105 ends

VALV VALV-150 D/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-202 Pump Control Valve 2 1 25 5 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-203 Pump Control Valve 2 1 25 5 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-204 Pump Control Valve 2 1 25 5 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-205 Pump Control Valve 2 1 25 5 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-250 U/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-251 U/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-252 U/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-253 U/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-272 U/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-283 D/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-286 D/S Isolation Valve 2 1 30 10 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-050 Other (Valves) 2 1 25 5 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-306 Other (Valves) 2 1 25 5 4 4 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-326 Other (Valves) 2 2 25 5
4" gate valve, isolation for zone-to-zone discharge to
ground, not included in 2015 assessment. 5 4 Medium Increased Maintenance/Operational Adjustments VALV VALV-327 Air Valve 2 2 30 10
Air valve on discharge manifold cross, not included in
2015 assessment. 5 2 Med-Low Increased Maintenance/Operational Adjustments VALV VALV-328 Pressure Relief Valve 2 2 25 5 Tank PRV, not included in 2015 assessment 5 4 Medium Increased Maintenance/Operational Adjustments VALV VALV-329 Air Valve 2 2 30 10
Suction side air valve on Pump 1 suction pipe, not
included in 2015 assessment. 5 2 Med-Low Increased Maintenance/Operational Adjustments ELEC GENR-012 Onsite Generator 3 2 25 5 5 4 Medium Increased Maintenance/Operational Adjustments INST INST-065 Level Sight Glass 2 1 30 10 4 2 Med-Low No Action Required BLDG BLDG-026 Structure 1 1 50 30 3 4 Med-Low No Action Required BLDG BLDG-027 Roof 1 1 50 30 3 4 Med-Low No Action Required PUMP PUMP-038 Pump 2 3 30 10 Replace. See recommendations in Table 2-7 6 3 Medium Replace $ 37,000 PUMP PUMP-039 Pump 2 5 30 10 Replace. See recommendations in Table 2-7 8 3 Medium Replace $ 37,000 PUMP PUMP-040 Pump 2 5 30 10 Replace. See recommendations in Table 2-7 8 3 Medium Replace $ 37,000 PUMP PUMP-041 Pump 2 3 30 10
Continue operating pump to failure.

See recommendations in Table 2-7 6 3 Medium No Action Required VALV VALV-051 Air Valve 2 1 30 10 4 2 Med-Low Replace $ 18,500 VALV VALV-304 D/S Isolation Valve 2 1 30 10 4 3 Med-Low Replace $ 29,903 INST INST-094 Pressure Element 3 1 15 13
D/S gauge for zone-to-zone PRV Heavy corrosion at
pipe connection 2 2 Low No Action Required
BLDG BLDG-039 Roll-up Door 1 1 50 30 3 3 Low No Action Required ACCS ACCS-013 Concrete 1 1 50 30 3 3 Low No Action Required FENC FENC-010 Fencing - Chain Link 1 1 40 20 3 3 Low No Action Required SEAL SEAL-038 Seals 2 1 30 16 3 3 Low No Action Required SEAL SEAL-039 Seals 2 1 30 16 3 3 Low No Action Required SEAL SEAL-040 Seals 2 1 30 16 3 3 Low No Action Required SEAL SEAL-041 Seals 2 1 30 16 3 3 Low No Action Required DRNG DRNG-011 Drainage 2 1 50 30 3 3 Low No Action Required c-268-40-22-15-wp-appD
City of Fairfield
Asset Management Plan Update

Page 941 of 1105 ends