Cities Index.
Agenda packet

Folsom City Council
October 25, 2022

Document
Agenda packet
Meeting
October 25, 2022
Body
Folsom City Council
Pages
482
Original file
33.2 MB
Text extracted from the city's file for reading and search. Open the original on mccmeetings.blob.core.usgovcloudapi.net. That file is the official record.

1 Agenda
City Council Regular Meeting
City Council Chambers | 50 Natoma Street, Folsom CA 95630 October 25, 2022
6:30 PM
Welcome to Your City Council Meeting
We welcome your interest and involvement in the city’s legislative process. This agenda includes information about topics coming before the City Council and the action recommended by city staff. You can read about each topic in the staff reports, which are available on the city website and in the Office of the City Clerk. The City Clerk is also available to answer any questions you have about City Council meeting procedures.

Participation
If you would like to provide comments to the City Council, please:
 Fill out a blue speaker request form, located at the back table.  Submit the form to the City Clerk before the item begins.  When it’s your turn, the City Clerk will call your name and invite you to the podium.  Speakers have three minutes, unless the presiding officer (usually the mayor) changes that time.

Reasonable Accommodations
In compliance with the Americans with Disabilities Act, if you are a person with a disability and you need a disability-related modification or accommodation to participate in this meeting, please contact the City Clerk’s Office at (916) 461-6035, (916) 355-7328 (fax) or [email protected]. Requests must be made as early as possible and at least two full business days before the start of the meeting.

How to Watch
The City of Folsom provides three ways to watch a City Council meeting:

In Person Online On TV

City Council meetings take place at
City Hall, 50 Natoma Street
Watch the livestream and replay past
meetings on the city website,
www.folsom.ca.us
Watch live and replays of meetings on
Sac Metro Cable TV, Channel 14

More information about City Council meetings is available at the end of this agenda

Page 1 ends

2 City Council Regular Meeting

Folsom City Council Chambers
50 Natoma Street, Folsom, CA

www.folsom.ca.us
Tuesday, October 25, 2022 6:30 PM

Kerri Howell, Mayor

Rosario Rodriguez, Vice Mayor Sarah Aquino, Councilmember YK Chalamcherla, Councilmember Mike Kozlowski, Councilmember

REGULAR CITY COUNCIL AGENDA
Effective July 7, 2022, the City of Folsom returned to all in-person City Council, Commission, and Committee meetings. Remote participation for the public will no longer be offered.

Everyone is invited and encouraged to attend and participate in City meetings in person.

CALL TO ORDER
ROLL CALL:

Councilmembers: Kozlowski, Rodriguez, Aquino, Chalamcherla, Howell The City Council has adopted a policy that no new item will begin after 10:30 p.m. Therefore, if you are here for an item that has not been heard by 10:30 p.m., you may leave, as the item will be continued to a future Council Meeting.

PLEDGE OF ALLEGIANCE

AGENDA UPDATE
BUSINESS FROM THE FLOOR:

Members of the public are entitled to address the City Council concerning any item within the Folsom City Council's subject matter jurisdiction. Public comments are limited to no more than three minutes. Except for certain specific exceptions, the City Council is prohibited from discussing or taking action on any item not appearing on the posted agenda.

SCHEDULED PRESENTATIONS:

1. Resolution of Commendation Honoring Kaiser Permanente on their 20th Anniversary in Folsom

2. Resolution of Commendation Honoring Folsom Residents Aimee Johns and Paul Bandy for their Efforts Rescuing a Shark Attack Victim

Page 2 ends

3 3. City of Folsom ALERT Rain and Stream Gauges for Enhanced Storm Response

4. Folsom Plan Area Semi-Annual Report
CONSENT CALENDAR:

Items appearing on the Consent Calendar are considered routine and may be approved by one motion. City Councilmembers may pull an item for discussion.

5. Approval of October 11, 2022 Special and Regular Meeting Minutes

6. Ordinance No. 1334 – An Ordinance of the City of Folsom Amending Section 5.20.070(A)(2) and Repealing Section 5.20.070(A)(13)(d) of the Folsom Municipal Code to Increase the Number of Card Tables and Allow Backline Betting (PN 22-157) (Second Reading and Adoption)

7. Resolution No. 10929 – A Resolution Authorizing the City Manager to Execute an Agreement with Illinois Tool Works Inc. dba EH Wachs for the Purchase of a Valve Truck Bed and Associated Equipment

8. Resolution No. 10930 – A Resolution Authorizing the City Manager to Execute an Agreement with Folsom Lake Ford for the Purchase of an eTransit Van

9. Resolution No. 10931 – A Resolution Authorizing the City Manager to Execute an Agreement with Dobbs Heavy Duty Holdings LLC, dba Dobbs Peterbilt for the Purchase of a Dump Truck and Appropriation of Funds

10. Resolution No. 10932 - A Resolution Authorizing an Appropriation of Funds for the Mangini Ranch Phase 1 Re-landscaping Project

11. Resolution No. 10933 – A Resolution Authorizing the City Manager to Execute Amendment No. 2 to the Professional Services Agreement with Mintier Harnish to Increase the Not-to-Exceed Amount for the Zoning Code Update Project

12. Resolution No. 10934 – A Resolution Authorizing the City Manager to Execute a Purchase Agreement with Golden State Fire Apparatus Inc. for One Type 3 Fire Engine

13. Resolution No. 10935 – A Resolution Authorizing the City Manager to Execute a Subdivision Improvement Agreement and Accept Offers of Dedication for the Broadstone Estates Subdivision, and Approval of the Final Map for the Broadstone Estates Subdivision

14. Objective Design and Development Standards and Green Means Go Grant Funding i. Resolution No. 10936 - A Resolution Authorizing the City Manager to Execute a Professional Services Agreement with Opticos for Development of Objective Design and Development Standards and Appropriation of Funds
ii. Resolution No. 10937 - A Resolution Authorizing Applications for the SACOG 2022 Green Means Go Funding Program

15. Resolution No. 10938 – A Resolution Authorizing the City Manager to Execute a Subdivision Improvement Agreement and Accept Offers of Dedication for the Mangini Ranch Phase 2 Village Nos. 5 & 6 Subdivision, and Approval of the Final Map for the Mangini Ranch Phase 2 Village Nos. 5 & 6 Subdivision

16. Resolution No. 10940 - A Resolution Authorizing the City Manager to Execute a Memorandum of Understanding between the City of Folsom and the International Union of Operating Engineers, Local 39
CITY MANAGER REPORTS:

COUNCIL COMMENTS:

Page 3 ends

4 ADJOURNMENT

NOTICE: Members of the public ar e entitled to directly address the City Council concerning any item that is described in the notice of this meeting, before or during consideration of that item. If you wish to address Council on an issue, which is on this agenda, please complete a blue speaker request card, and deliver it to a staff member at the table on the left side of the Council Chambers prior to discussion of the item. When your name is called, stand to be recognized by the Mayor and then proceed to the podium. If you wish to address the City Council on any other item of interest to the public, when the Mayor asks if there is any “Business from the Floor,” follow the same procedure described above. Please limit your comments to three minutes or less.

NOTICE REGARDING CHALLENGES TO DECISIONS: Pursuant to all applicable laws and regulations, including without limitation, California Government Code Section 65009 and or California Public Resources Code Section 21177, if you wish to challenge in court any of the above decisions (regarding planning, zoning and/or environmental decisions), you may be limited to raising only those issues you or someone else raised at the public hearing(s) described in this notice/agenda, or in written correspondence delivered to the City at, or prior to, the public hearing.

As presiding officer, the Mayor has the authority to preserve order at all City Council meetings, to remove or cause the removal of any person from any such meeting for disorderly conduct, or for making personal, impertinent, or slanderous remarks, using p rofanity, or becoming boisterous, threatening or personally abusive while addressing said Council, and to enforce the rules of the Council.

PERSONS INTERESTED IN PROPOSING AN ITEM FOR THE CITY COUNCIL AGENDA SHOULD CONTACT A MEMBER OF THE CITY COUNCIL.

The meeting of the Folsom City Council is being telecast on Metro Cable TV, Channel 14, the Government Affairs Channel, and will be shown in its entirety on the Friday and Saturday following the meeting, both at 9 a.m. The City does not control scheduling of this telecast and persons interested in watching the televised meeting should confirm this schedule with Metro Cable TV, Channel 14. The City of Folsom provides live and archived webcasts of regular City Council meetings. The webcasts can be found on the online services page of the City's website www.folsom.ca.us.

In compliance with the Americans with Disabilities Act, if you are a person with a disability and you need a disability-related modification or accommodation to participate in this meeting, please contact the City Clerk’s Office at (916) 461-6035, (916) 355-7328 (fax) or [email protected]. Requests must be made as early as possible and at least two full business days before the start of the meeting.

Any documents produced by the City and distributed to the City Council regarding any item on this agenda will be made available at the City Clerk’s Counter at City Hall located at 50 Natoma Street, Folsom, California and at the Folsom Public Library located at 411 Stafford Street, Folsom, Calif ornia during normal business hours.

Page 4 ends

City of Folsom
Resolution of Commendation
Honoring
Kaiser Permanente on their zotrAnniversary
WHEREAS, Kaiser Permanente is the nation's oldest and largest not-for-profit integrated health care system founded 77 years ago in Oakland, Galifornia by Henry J. Kaiser, an industrialist who believed in providing affordable, quality health care; and WHEREAS, Kaiser Permanente began providing health care in the Sacramento area for the first time in 1965, and is now serying more than 945,000 members locally, and is the largest health care provider in the Greater Sacramento area; and
WHEREAS, the Folsom Medical Offices were opened on October 28,2002, to better serve their growing membership in the area; and
WHEREAS, the Folsom Medical Offices will celebrate 20 years of service to the community on October 28,2022; and
WHEREAS, Kaiser Permanente now provides health care for more than 80,000 Folsom members at their Folsom Medical Offices; and
WHEREAS, medical services provided at the Folsom Medical Offices includes adult medicine, pediatrics, women's health, mental health, laboratory, radiology, pharmacy, optometry, optical sales, physicaltherapy, and health education; and
WHEREAS, approximately 80 physicians and approximately 370 staff and other providers care for their members at the Folsom Medical Offices; and
WHEREAS, for nearly a decade, Kaiser Permanente Folsom has been a key partner with the Folsom Gommunity Service Day and annualfood drive; and
WHEREAS, Kaiser Permanente Folsom is certified by the League of American Bicyclists as a Gold Level Bicycle Friendly business with a bike share program and cycling club; and WHEREAS, as a not-for-profit health care provider, Kaiser Permanente's mission is to improve the health and well-being of their members and the communities they serve:

NOW, THEREFORE, l, KERRI M. HOWELL, Mayor of the City of Folsom, on behalf of the Folsom City Council and the citizens of tne Folsom community, do hereby thank Kaiser Permanente for providing quality healthcare to Folsom and congratulate them on their 20th Anniversary.

PASSED AND APPROVED, this 25th day of Odober2Q22.

Attest:

Kerri M. Howell, MAYOR Lydia Konopka, DEPUTY CITY CLERK

Page 5 ends

10/25/2022 Item No.1.

This page is intentionally lefr blank.

Page 6 ends

10/25/2022 Item No.1.

City of Folsom
Resolution of Commendation
Honofug
Folsom Residents Aimee Johns and Paul Bandy
For lheir Efforts Rescuing a SharkAttackVictim
WHEREAS, Folsom residents Aimee Johns, a Registered Nurse at Sutter Medical Center in Sacramento, and her husband Paul Bandy, a Police Officer with Sacramento Police Department, risked their lives to help save a swimmer at Lovers Point Beach in the town of Pacific Grove on June 22, 2022, and
WHEREAS, the vacationing Folsom couple were celebrating their 12th wedding anniversary with paddleboarding at the Monterey Bay cove when they heard screams for help and noticed a man in distress, and WHEREAS, along with another good Samaritan who was teaching a surf instruction nearby, Aimee and Paul took immediate action and personal risk and pulled the shark-bite victim onto a surfboard and brought him back to shore to receive first aid, and
WHEREAS, the fast actions of Aimee and Paul allowed medics to get shark attack survivor Steve Bruemmer to a trauma center in time to receive life-saving care, and
WHEREAS, Aimee and Paul have since received multiple awards and commendations for their selfless acts of bravery:

NOW, THEREFORE, l, KERRI M. HOWELL, Mayor of the City of Folsom, on behalf of the Folsom City Council, do hereby thank Folsom residents Aimee Johns and Paul Bandy for their efforts to rescue shark aftack victim Steve Bruemmer.

PASSED AND APPROVED, this 25th day of October 2022.

Kerri M. Howell, MAYOR
Aftest:

Lydia Konopka, DEPUTY CITY CLERK
,\, ,\'ll
'/i
.o\rliW
,$
'ri It
il,'
r ' 1-',
.v-"$'

Page 7 ends

10/25/2022 Item No.2.

This page is intentionally trefr blank.

Page 8 ends

10/25/2022 Item No.2.
i i-'l.i 'l:"{.}iylt. :tia;;;.rn r': : !t, jrj
Folsom City Council
Staff Re ort

BACKGROUND / ISSUE
The Public Works Department recently completed work to upgrade the City's rain and stream gauge system as part of the City's overall efforts to enhance flood awareness and response activities. Staff will be presenting a summary of the work completed to date, including physical gauge installations, data collections, and the online platform for viewing the information collected. The presentation will outline the initial benefits to our flood response efforts, as well as identiff ongoing efforts and activities to further expand on the usefulness of the system for our City-wide flood preparedness.

Submitted,
Mark Rackovan, PUBLIC WORKS DIRECTOR
MEETING DATE: 1012512022
AGENDA SECTION: Scheduled Presentations
SUBJECT: City of Folsom ALERT Rain and Stream Gauges for Enhanced Storm Response
FROM: Public Works Department
I

Page 9 ends

10/25/2022 Item No.3.

This page is intentionally left blank.

Page 10 ends

10/25/2022 Item No.3.
ff,rtil&iH',s_+F:l
$i *!i rs*r? a ir tttai;t3
Folsom City Council
Staff ort
MEETING DATE: 10tzs12022
AGENDA SECTION: Scheduled Presentations
SUBJECT: Folsom Plan Area Semi-Annual Report
F'ROM: Community Development Department

RECOMMENDATION / CITY COUNCIL ACTION
No action is requested of the City Council at this time.

BACKGROUND / ISSUE
Community Development staff will provide an update on the planning, engineering and building activity in the Folsom Plan Area south of Highway 50 during the six month period from April l't through September 301h,2022.

Submitted,
Pam Johns, Community Development Director
1

Page 11 ends

10/25/2022 Item No.4.

This page is intentionally trefr blank.

Page 12 ends

10/25/2022 Item No.4.

Book 76 Page 314
Folsom City Council
October 11,2022
Gity Gouncil Special Meeting

MINUTES
Tuesday, October 11,2022 6:00 PM

CALL TO ORDER
The special City Council meeting was called to order at 6:02 p.m. with Vice Mayor Rosario Rodriguez presiding.

ROLL GALL:

Councilmembers Present YK Chalamcherla, Councilmember
Rosario Rodriguez, Vice Mayor
Sarah Aquino, Councilmember
Councilmembers Absent: Mike Kozlowski, Councilmember
Kerri Howell, Mayor
Participating Staff: City Manager Elaine Andersen
City Attorney Steve Wang
City Clerk Christa Freemantle
ADJOURNMENT TO GLOSED SESSION FOR THE FOLLOWING PURPOSES:

1. Conference with Legal Counsel Anticipated Litigation, lnitiation of Litigation Pursuant to Government Code Section 54956.9(d)(4): One Potential Case Motion by Councilmember Sarah Aquino, second by Councilmember YK Chalamcherla, to adjourn to Closed Session for the above referenced item. Motion carried with the following roll callvote:

AYES:

NOES:

ABSENT:

ABSTAIN:

Gouncilmember(s): Ghalamcherla, Rodriguez, Aquino
Councilmember(s): None
Gouncilmember(s): Kozlowski, Howell
Councilmember(s): None

RECONVENE
City Attorney Steven Wang announced that the City Council authorized the City Attorney to initiate litigation in one case.

Draft - Not Official Until Approved Page 13
10/25/2022 Item No.5.

Book 76 Page 315
Folsom Ci$ Council
October 11,2022

ADJOURNMENT
The special meeting was adjourned to the regular City Council meeting at 6:43 p.m

SUBMITTED BY
Christa Freemantle, City Clerk
ATTEST:

Rosario Rodriguez, Vice Mayor
Draft- Not Officiol Until Approved Page 14
10/25/2022 Item No.5.

Book 76 Page 316
Folsom City Council
October 11,2022
Gity Council Regular Meeting

MINUTES
Tuesday, October 11,2022 6:30 PM

CALL TO ORDER
The regular City Council meeting was called to order at6:44 pm with Mayor Kerri Howell presiding ROLL GALL:

Councilmembers Present: YK Chalamcherla, Councilmember
Mike Kozlowski, Councilmember
Rosario Rodriguez, Vice Mayor
Sarah Aquino, Councilmember
Kerri Howell, Mayor
Councilmembers Absent: None
Participating Staff: City Manager Elaine Andersen
City Attorney Steven Wang
City Clerk Christa Freemantle
Parks and Recreation Director Lorraine Poggione
Recreation and Community Services Manager Tom Hellmann
Landscape Services Manager Zach Perras
Principal Planner Steve Banks
Public Works Director Mark Rackovan
Public Works Engineering Manager Brian Reed
Arborist Aimee Nunez

PLEDGE OF ALLEGIANCE
The Pledge of Allegiance was recited

AGENDA UPDATE
City Attorney Steven Wang announced that there were updates to item 12 BUSINESS FROM THE FLOOR:

The following speakers addressed the City Council:

1. Aaron Hadzess regarding supporting local workers
Droft - Not Official Until Approved

Page 15 ends

10/25/2022 Item No.5.

Book 76 Page 317
Folsom City Council
October 11,2022
SGHEDULED PRESENTATIONS:

1. Presentationof 2Q22 Community Service Day Results
Parks and Recreation Director Lorraine Poggione introduced the item and Recreation and Community Services Manager Tom Hellmann made a presentation.

2. Proclamation of the Mayor of the City of Folsom Proclaiming October 2022 as National Arts and Humanities Month
Councilmember Sarah Aquino presented the proclamation.

3. Project Update of the Capital Southeast Connector Segment D3 Public Works Director Mark Rackovan introduced the item and Public Works Engineering Manager Brian Reed made a presentation and responded to questions from the City Council.

CONSENT GALENDAR:

4. Approval of September 27,2022 Special and Regular Meeting Minutes

5. pulled for discussion

6. Ordinance No. 1333 - An Ordinance of the City of Folsom Removing Limitations on Frequency of Garage Sales by Repealing Section 5.09.020 from the Folsom Municipal Code (Second Reading and Adoption)

7. pulled for discussion

8. Resolution No. 10926 - A Resolution Authorizing the City Manager to Execute a Construction Change Order with Central Valley Engineering and Asphalt, lnc. for the On-Call Concrete and Asphalt Maintenance Services Project (Contract 174-21 21-073) and Appropriation of Funds

9. Resolution No. 10927 - A Resolution Authorizing the City Manager to Execute a Consultant and Professional Services Agreement with West Coast Arborists, lnc. for On-Call Tree Trimming and Removal Services

10. Resolution No. 10928 - A Resolution Authorizing the City Manager to Execute an Agreement with Folsom Lake Ford for the Purchase of a Crane Truck
Motion by Vice Mayor Rosario Rodriguez, second by Councilmember Mike Kozlowski, to approve Gonsent Galendar items 4, 6, 8-10.

Motion carried with the following roll call vote:

AYES: Councilmember(s): Chalamcherla, Kozlowski, Rodriguez, Aquino, Howell NOES: Gouncilmember(s): None
ABSENT: Councilmember(s): None
ABSTAIN: Councilmember(s): None
Droft - Not officiol Until Approved

Page 16 ends

10/25/2022 Item No.5.

Book 76 Page 318
Folsom City Council
October 11,2022
CONSENT CALENDAR ITEMS PULLED FOR DISCUSSION:

4. Appointment of At-Large Member to the Folsom Landscaping and Lighting District Advisory Committee to Represent the Prospect Ridge District
Applicant Benjamin Mattocks introduced himself and expressed his interest in working with the Landscaping and Lighting District Advisory Committee.

Motion by Vice Mayor Rosario Rodriguez, second by Gouncilmember YK Ghalamcherla, to appoint Benjamin Mattocks to the Folsom Landscaping and Lighting District Advisory Gommittee to represent the Prospect Ridge District for the term ending in December 2024.

Motion carried with the following roll callvote:

AYES: Gouncilmember(s): Ghalamcherla, Kozlowski, Rodriguez, Aquino, Howell NOES: Gouncilmember(s): None
ABSENT: Gouncilmember(s): None
ABSTAIN: Gouncilmember(s): None
7 . Resolution No. 10925- A Resolution Authorizing the City Manager to Execute a Design Consulting Services Agreement with TAIT Environmental Services, lnc. for the Corporation Yard Fuel Tank and Fuel Management System Replacement Project Mayor Kerri Howell pulled this item to address a resident email asking for the reasons/justifications for the tank replacement. She explained the replacement of the above-ground storage tank is needed to address inadequate size and to address leakage into the secondary containment vessel (which she noted does not result in contamination).

Motion by Vice Mayor Rosario Rodriguez, second by Councilmember YK Chalamcherla to approve Resolution No. 10925.

Motion carried with the following roll call vote:

AYES: Gouncilmember(s): Chalamcherla, Kozlowski, Rodriguez, Aquino, Howell NOES: Gouncilmember(s): None
ABSENT: Gouncilmember(s): None
ABSTAIN: Councilmember(s): None
PUBLIC HEARING:
1 1. Resolution No. 10924 - A Resolution Reducing the Annual Assessment in the Final Engineer's Report for Fiscal Year 2022-23 for Blue Ravine Oaks No. 2 Landscaping and Lighting District Landscape Services Manager Zach Perras made a presentation and responded to questions from the City Council.

Mayor Kerri Howell opened the Public Hearing. Hearing no speakers, the Public Hearing was closed Motion by Councilmember Mike Kozlowski, second by Vice Mayor Rosario Rodriguez to approve Resolution No. 10924.

Droft - Not Official Until Approved

Page 17 ends

10/25/2022 Item No.5.

Book 76 Page 319
Folsom City Council
October 11,2022
Motion carried with the following roll call vote:

AYES: Councilmember(s): Ghalamcherla, Kozlowski, Rodriguez, Aquino, Howell NOES: Councilmember(s): None
ABSENT: Councilmember(s): None
ABSTAIN: Councilmember(s): None
NEW BUSINESS:

12. Ordinance No. 1334 - An Ordinance of the City of Folsom Amending Section 5.20.070(A)(2) and Repealing Section 5.20.070(AX13Xd) of the Folsom Municipal Code to lncrease the Number of Card Tables and Allow Backline Betting (PN 22-157) (lntroduction and First Reading) Principal Planner Steve Banks made a presentation and responded to questions from the City Council.

Motion by Vice Mayor Rosario Rodriguez, second by Gouncilmember YK Ghalamcherla to introduce Ordinance No. 1334.

Motion carried with the following roll call vote:

AYES: Gouncilmember(s): Ghalamcherla, Kozlowski, Rodriguez, Aquino, Howell NOES: Gouncilmember(s): None
ABSENT: Gouncilmember(s): None
ABSTAIN: Gouncilmember(s): None

13. Landmark Tree Considerations and Direction to Staff Arborist Aimee Nunez made a presentation and responded to questions from the City Council.

Following the presentation and discussions with staff, the City Council expressed conceptual support for the designation of individual landmark trees with the cooperation and support of the relevant landowners. The City Council supported continuing review and analysis of options related to tree groves, noting the need for California Department of Corrections and Rehabilitation cooperation relative to the grove of trees on prison property. The City Council also suggested staff consider future updates to the Tree Preservation Ordinance regarding the landmark tree designation process, definitions, grove qualifications, and related matters, along with renewed outreach to the public regarding maintenance of trees during drought conditions.

CITY MANAGER REPORTS:

City Manager Elaine Andersen invited residents to the Friends of the Folsom Zoo Sanctuary Breakfast, the Folsom Fire Department Open House and Pancake BreaKast, the Public Safety Trunk or Treat event, the Diwali Festival of Lights event, and the Wildwood Performing Arts Foundation event.

GOUNGIL GOMMENTS:

Vice Mayor Rosario Rodriguez congratulated Visconti's restaurant and Powerhouse Ministries on their respective anniversaries. She spoke of the Livability Summit for the unhoused, congratulated Folsom Police Foundation on their recent gala event, the Folsom Homecoming Parade, the non-profit Draft - Not officiol Until Approved

Page 18 ends

10/25/2022 Item No.5.

Book 76 Page 320
Folsom City Council
October 11,2022
community showcase, Spirit Brews, soapbox derby, and rotary events. She inquired about possible city projects in the pipeline that need to be brought before the City Council, given recent light agendas.

Councilmember YK Chalamcherla spoke of Future Folsom and the retention of PowerSchool, solicitation of technology firms, Octoberfest, Pinebrook Village, Community Service Day, and election season.

Councilmember Mike Kozlowski spoke of Public Works Projects that he would like to see come back to Council for discussion including crosswalk pavement markings, pipe work in the Hinkle Creek area. He also mentioned the Muslim Center Open House and SACOG's Youth Leadership Academy.

Mayor Kerri Howell spoke of Reginal Sanitation and Regional Transit meetings, Measure A expenditures, Community Service Day, Visconti's restaurant and Powerhouse Ministries.

ADJOURNMENT
There being no further business to come before the Folsom City Council, Mayor Kerri Howell adjourned the meeting in memory of Shauna Ryan at 8:23 pm.

SUBMITTED BY
Christa Freemantle, City Clerk
ATTEST
Kerri Howell, Mayor
Draft - Not Officiol Until Approved

Page 19 ends

10/25/2022 Item No.5.

This page is intentionally treft blank.

Page 20 ends

10/25/2022 Item No.5.

Folsom City Council
Staff ort
MEETING DATE: 1012512022
AGENDA SECTION: Consent Calendar
SUBJECT: Ordinance No. 1334 - An Ordinance of the City of Folsom Amending Section 5.20.070(AX2) and Repealing Section

5.20.070(A)(13Xd) of the Folsom Municipal Code to Increase the Number of Card Tables and Allow Backline Betting
(PN 2z-lsTXSecond Reading and Adoption)
F'ROM: Community Development Department

RECOMMENDATION / CITY COUNCIL ACTION
Move to Adopt Ordinance No. 1334 - An Uncodified Ordinance of the City of Folsom Amending Section 5.20.070(AX2) and Repealing Section 5.20.070(AX13Xd) of the Folsom Municipal Code to Increase the Number of Card Tables and Allow Backline Betting.

BACKGROUND / ISSUE
On June l, 2022, Delta C, LP submitted an application to the City requesting approval of a Municipal Code Amendment to amend the City of Folsom Cardroom Ordinance with the pu{poses of (l) increasing the number of permitted card tables in any cardroom from 9 to 1 1; and (2) allowing the practice of Backline Betting to occur in any cardroom. Delta C, LP stated in their application that these amendments to the City's Cardroom Ordinance are necessary for the cardroom to be able to compete with cardrooms in other local jurisdictions in the Sacramento area.

The following are the specific amendments to the Cardroom Ordinance that were originally proposed by the applicant:

Amend Chapter 5.20, Section 5.20.070(AX2) of the Folsom Municipal Code to increase the number of card tables in the City from 9 to 11, pursuant to the allowance provided by Business and Professions Code $ 1996I.06(b), and add language to this Section that would allow the City to take advantage of any future table increases authorized by the Legislature without amending the Cardroom Ordinance as follows:

I
a

Page 21 ends

10/25/2022 Item No.6.
a

5.20.07 0 Cardroom regulations.

A. No person shall operate a cardroom in violation of any of the following regulations:

2. No more than *+ae eleven (l ll card tables shall be permitted in any cardroom.

However. should judicial or leqislative action alter the restrictions or limitations in the Gamblins Control Act, Business and Professions Code section 19800 et seo.. to allow -for an increase in the curyent number of tables without voter approval, the maximum number of tables permitted in any carlltoom may be increased, subiect to cit.v council allocation by Resolution, up to the amount such iudicial or legislative allows not to exceed a
Delete Section 5.20.070(AX13Xd) of the Folsom Municipal Code, which currently prohibits the practice of "Backline Betting" within the City as follows

13. The following provisions shall govern wagering limits: It is unlawful for any person to bet or wager at or against any card game held at a licensed gaming club except as allowed by this chapter. In addition to any conditions that may be imposed on a license, the following restrictions shall apply:

On September 13, 2022, City staff provided the City Council with an overview of the proposed amendment to the Cardroom Ordinance for the purpose of soliciting feedback and receiving direction from the Council. The Council discussed the proposed cardroom amendments and indicated that they were supportive of the proposed amendments.

On October 11,2022, the City received a letter from the State Bureau of Gambling Control (Bureau) regarding the proposed Cardroom Ordinance Amendment. In their letter, the Bureau indicated that applicant's request to increase the number of card tables from 9 to 11 and the request to repeal language prohibiting Backline Betting were consistent with the State Gambling Control Act. However, the Bureau stated that the language in the Cardroom Ordinance Amendment that provides for the 'oautomatic" increases to the number of cardrooms was not consistent with the Gambling Control Act. As a result, the Bureau recommended that the language in the Cardroom Ordinance Amendment that provides for "automatic" increases in the number of card tables be eliminated. City staff consulted with the project applicant and they were agreeable to modifuing the Cardroom Ordinance Amendment as follows:
2 Page 22
10/25/2022 Item No.6.

SECTION 2 AMENDMENT TO CODE
Section 5.20.070(AX2) of the Folsom Municipal Code is hereby amended to read as follows:

5.20.07 0 Cardroom regulations.

A. No person shall operate a cardroom in violation of any of the following regulations:

2. No more than eleven (11) card tables shall be permitted in any cardroom.

HeweYerr should jrr ion"
inereesedr subjee
{abl€s'
On October 11,2022, the City Council reviewed the proposal from Delta C, LP for approval of a Municipal Code Amendment to amend the City of Folsom Cardroom Ordinance with the purpose of increasing the number of permiued card tables in any cardroom from 9 to 11 and allowing the practice of Backline Betting to occur in any cardroom. The City Council expressed their support for the proposed project as amended and voted (5-0-0-0) to introduce and conduct first reading of Ordinance No. 1334 (An Ordinance of the City of Folsom Amending Section 5.20.070(AX2) and Repealing Section 5.20.070(AX13Xd) of the Folsom Municipal Code to Increase the Number of Card Tables and Allow Backline Betting).

POLICY / RULE
Under Section 2.I2 of the City Charter, amendments to the Folsom Municipal Code require review and approval by the City Council.

ANALYSIS
As referenced in the Background section of this report, the proposed Municipal Code Amendment would amend the City of Folsom's Cardroom Ordinance with the goals of (1) increasing the number of permitted card tables in any cardroom from 9 to I 1; and (2) allowing the practice of Backline Betting to occur in any cardroom. The implications associated with these two amendments are a minor increase in the number of customers (potentially 20 additional customers) and employees (potentially 5-10 additional employees) present in a cardroom atany given point in time.

In evaluating the proposed Cardroom Ordinance, City staff consulted with the appropriate internal staff including the Chief of Police, Fire Chief, Chief Building Offrcial, Code Enforcement Supervisor, Community Development Director, and City Attorney. In addition, City staffalso solicited feedback regarding general cardroom operations and concerns from J Page 23
10/25/2022 Item No.6.
code enforcement officers throughout the Sacramento region. The general consensus of the outreach effort with the aforementioned individuals and groups was that there were no concerns with the proposed Cardroom Ordinance due the limited nature of the proposed modifications. As a result, City staff determined that the proposed Cardroom Ordinance will not be likely to result in any direct impacts (traffic, parking, noise, aesthetics, safety, etc.) due to the fact that the Ordinance is simply providing the opportunity for a cardroom to increase the number of card tables within an establishment while also allowing for increased participation at the card tables through the process of Backline Betting. Any cardroom seeking to operate 11 tables arrdlor allow backline betting must receive individual approval from the City Council pursuant to the Cardroom Ordinance.

The applicant for the proposed Cardroom Ordinance (Delta C, LP) indicated that it is their intent to apply for a Conditional Use Permit and Cardroom License to own and operate a cardroom within an existing 4,680-square-foot freestanding commercial building (formerly Applebee's Restaurant and Casa Ramos Restaurant) located at 400 Iron Point Road. The Conditional Use Permit, which will be subject to review and approval by the Planning Commission, will include an extensive evaluation of potential direct impacts associated with the cardroom including but not limited to site design, vehicle access and circulation, parking, noise, safety, building design, signage, and dayslhours of operation. The Cardroom License will be subject to separate review and approval by the City Council.

FINANCIAL IMPACT
A recent Economic Impact Analysis (Analysis) commissioned by the California Gaming Commission in 2019 (https://californiagamineassociation.org/cardroomimpact/) found the total annual economic impact of California's cardroom industry to be $5.6 billion dollars, providing over 32,000 local jobs.

ENVIRONMENTAL REVIEW
The project is categorically exempt under Section 15061(bX3) Review for Exemption of the California Enyironmental Quality Act (CEQA). New cardroom applications (Conditional Use Permit) in the City will be subject to CEQA review

ATTACHMENTS

1. Ordinance No. 1334 - An Ordinance of the City of Folsom Amending Section

5.20. 070(A)(2) and Repealing Section 5.20. 070(AX I 3 Xd) of the Eolsom Municipal Code to Increase the Number of Card Tables and Allow Backline Betting. 4 Page 24
10/25/2022 Item No.6.

Submitted,

PAM JOHNS
Community Development Director
5 Page 25
10/25/2022 Item No.6.

Attachment I
Ordinance No. 1334 - An Ordinance of the City of
Folsom Amending Section 5.20.070(A)(2) and
Repealing Section 5.20.070(AX13Xd) of the Folsom
Municipal Code to Increase the Number of Card
Tables and Allow Backline Betting

Page 26 ends

10/25/2022 Item No.6.

ORDINANCE NO. 1334
AN ORDINANCE OF THE CITY OF'FOLSOM AMENDING SECTION 5.20.070(AX2) AND REPEALING SECTION A)fl3(d) OF'THE FOLSOM MUNICIPAL CODE TO INCREASE THE I\UMBER OF CARD TABLES AND ALLOW BACKLINE

BETTING
The City Council of the City of Folsom does hereby ordain as follows SECTION 1 PURPOSE
The purpose of this Ordinance is to amend the Folsom Municipal Code to increase the number of card tables in the City from 9 to 11 pursuant to the allowance provided by Business and Professions Code $ 19961.06(b) and to allow the practice of "Backline Betting" within the City.

SECTION 2 AMENDMENT TO CODE
Section 5.20.070(A)(2) of the Folsom Municipal Code is hereby amended to read as follows

5.20.07 0 Cardroom regulations.

A. No person shall operate a cardroom in violation of any of the following regulations:

2. No more than eleven (11) card tables shall be permitted in any cardroom.

SECTION 3 REPEAL OF CODE
Section 5.20.070(AXl3Xd) is hereby deleted from the Folsom Municipal Code in its entirety
SECTION 4 SCOPE
Except as set forth in this ordinance, all other provisions of the Folsom Municipal Code shall remain in full force and effect.

SECTION 5 SEVERABILITY
If any section, subsection, sentence, clause, or phrase in this Ordinance or any part thereof is for any reason held to be unconstitutional, invalid, or ineffective by any court of competent jurisdiction, such decision shall not affectthe validity or effectiveness of the remaining portions of this Ordinance or any part thereof. The City Council declares that it would have passed each section irrespective of the factthat any one or more section, subsection, sentence, clause, or phrase be declared unconstitutional, invalid, or ineffective.

Ordinance No. 1334
Page I of2

Page 27 ends

10/25/2022 Item No.6.

ABSENT:

ABSTAIN
SECTION 6 EFFECTIVE DATE
This ordinance shall become effective thirfy (30) days from and after its passage and adoption, provided it is published in full or in summary within twenty (20) days after its adoption in a newspaper of general circulation in the City.

This ordinance was introduced and the title thereof read at the regular meeting of the City Council on October 11,2022, and the second reading occurred at the regular meeting of the City Council on October 25,2022.

On a motion by Council Member seconded by Council Member the foregoing ordinance was passed and adopted by the City Council of the City of Folsom, State of California, this 25th day of October , 2022 by the following roll-call vote:

AYES: Councilmember(s):

Councilmember(s):

Councilmember(s):

Councilmember(s):

NOES:

Keni M. Howell, MAYOR
ATTEST:

Christa Freemantle, CITY CLERK
Ordinance No. 1334
Page2 of2

Page 28 ends

10/25/2022 Item No.6.

Folsom City Council
Staff ort
MEETING DATE: r0t2s12022
AGENDA SECTION: Consent Calendar
SUBJECT: Resolution No.10929- A Resolution Authorizing the City Manager to Execute an Agreement with Illinois Tool Works Inc. dba EH Wachs for the Purchase of a Valve Truck Bed and
Associated Equipment
FROM: Environmental and Water Resources Department

RECOMMENDATION / COUNCIL ACTION
The Environmental and Water Resources Departments recommends that the City Council pass and adopt Resolution No. 10929 - A Resolution Authorizrngthe City Manager to Execute an Agreement with Illinois Tool Works Inc. dba EH Wachs for the Purchase of a Valve Truck Bed and Associated Equipment.

BACKGROUND / ISSUE
The Environmental and Water Resources Department (EWR) recognizes the need to maintain a fleet of vehicles that will be able to provide reliable, efficient and responsive service. In coordination with Fleet staff, current department vehicles are reviewed to help identifu priority vehicles for replacement based on service life, mileage and purpose. The current valve truck used by the Water Qualrty Division has, based on this review, exceeded its' expected service life in terms of age, mileage and ongoing maintenance costs. This agreement will facilitate procurement of a new valve truck bed and associated equipment, to be installed on a replacement truck to be purchased by the Water Quality Division.

This resolution authorizes the City Manager to execute an agreement with Illinois Tool Works Inc. dba EH Wachs for the purchase of a valve truck bed and associated equipment for a total amount of $17I,667.25.
1 POLICY / RULE

Page 29 ends

10/25/2022 Item No.7.

Section 2.36.120 of the Folsom Municipal Code states, in part, that contracts for supplies, equipment, services, and construction with an estimated value of $66,141 or greater shall be awarded by the City Council.

Section 2.36.170 of the Folsom Municipal Code permits cooperative purchasing agreements for the procurement of any supplies, equipment, service, or construction with one or more public procurement units in accordance with an agreement entered into or between the participants.

ANALYSIS
Review of EWR vehicles identified the Water Quality Division's valve truck as high priority for replacement. The valve truck is an essential piece of equipment used for exercising valves within the water distribution system, which is a requirement of the California code of regulations. The truck and associated equipment currently in use was purchased in 2006 and has already undergone various repairs, resulting in the vehicle and equipment being out of service for a total of at least l0 weeks during the past year.

EWR staff coordinated with Fleet staff to obtain a quote for a replacement valve truck. At this time, the City is unable to obtain a quote or submit a direct order for the actual vehicle until later this year but has received a quote for the truck bed and associated equipment.

Illinois Tool Works Inc. dba EH Wachs submitted a quote through BuyBoard for the required truck bed and equipment for a total of $171,667.25.8uy8oard is a national cooperative purchasing entity of which the City of Folsom is a member. The City has purchased numerous items through BuyBoard. Illinois Tool Works Inc. dba EH Wachs has a current contract with BuyBoard for providing Construction, Road and Bridge, Ditching, Trenching and Other Equipment at a price that has been assessed to be fair, reasonable, and competitive.

BuyBoard contract number #597-19 will be utilized for the purchase of the valve truck bed and associated equipment, for a total of $171,667.25. This price includes taxes and delivery to a facility for assembly on a vehicle (to be purchased by the City) at a future date. The vehicle on which the equipment will be assembled is estimated to cost $70,000. EWR staff will retum to City Council for approval for this purchase at a later date when relevant quotes are available.

Fleet staff recommended ordering the truck bed and equipment prior to purchasing the vehicle.

Waiting several months until the orders for the vehicle and associated equipment can be combined into one order could result in an increased overall cost to the City. By placing the order for the truck bed and equipment now, the current pricing is guaranteed, but the schedule for production and assembly will still be coordinated with production of the associated vehicle, which EWR plans to purchase as soon as orders are accepted by the vendor.

FINANCIAL IMPACT
Sufficient funds are budgeted and available in FY 2022-23 in the Water Operating Fund (Fund 520) for the requested truck bed and equipment purchase for a total price of $171,667.25. 2 Page 30
10/25/2022 Item No.7.

The replaced vehicle and associated equipment will be sold in accordance with Folsom Municipal Code, section 2.36.220, Disposition of surplus personal property.

ENVIRONMENTAL REVIEW
This action is exempt from environmental review under the California Environmental Quality Act (CEQA).

ATTACHMENT
Resolution No. 10929 - A Resolution Authorizing the City Manager to Execute an Agreement with Illinois Tool Works Inc. dba EH Wachs for the Purchase of a Valve Truck Bed and Associated Equipment
Submitted,
Marcus Yasutake, Director

ENVIRONMENTAL AND WATER RESOURCES DEPARTMENT
J Page 31
10/25/2022 Item No.7.

RESOLUTION NO. 10929

A RESOLUTION AUTHORIZING THE CITY MANAGER TO EXECUTE AN AGREEMENT WITH ILLINOIS TOOL WORKS INC. DBA EH WACHS F'OR THE

PURCHASE OF A VALVE TRUCK BED AND ASSOCIATED EQUIPMENT
WHEREAS, Environmental and Water Resources Department staff has validated the need to purchase a replacement valve truck with associated equipment based on an approved replacement schedule; and
WHEREAS, orders are not currently being accepted for the required vehicle for the valve truck; and
WHEREAS, Fleet staff recommended that there will be a cost saving if the truck bed and equipment is ordered separately to the vehicle; and
WHEREAS, Illinois Tool Works Inc. dba EH Wachs has provided a quote for the truck bed and equipment and will coordinate assembly with the vehicle when purchased; and WHEREAS, this purchase will be made through BuyBoard, r,vhich used its recognized cooperative purchasing agreement to award a contract to Illinois Tool Works Inc. dbaEH Wachs in an amount not to exceed $171,667.25; and
WHEREAS, sufficient funds are budgeted and available in the Water Operating Fund (Fund 520) for this purchase; and
WHEREAS, replaced equipment will be sold in accordance with Folsom Municipal Code section 2.36.220, Disposition of surplus personal property; and WHEREAS, the agreement will be in a form acceptable to the City Attomey:

NOW, THEREFORE, BE IT RESOLVED that the City Council of the City of Folsom authorizes the City Manager to execute an Agreement with Illinois Tool Works Inc. dba EH Wachs for the purchase of a Valve Truck Bed and Associated Equipment for a not-to-exceed amount of $171,667.25.

PASSED AND ADOPTED this 25th day of October,2\22,by the following roll-call vote:

AYES:

NOES:

ABSENT:

ABSTAIN:

Councilmember(s):

Councilmember(s):

Councilmember(s):

Councilmember(s):

Resolution No. 10929
Page I of2 Page 32
10/25/2022 Item No.7.

Keni M. Howell, MAYOR
ATTEST:

Christa Freemantle, CITY CLERK
Resolution No. 10929
Page2 of2 Page 33
10/25/2022 Item No.7.

This page is intentionally trefr blank.

Page 34 ends

10/25/2022 Item No.7.
:'. .:; r !::.: r !: i .lr
Folsom City Council
Staff

RECOMMENDATION / CITY COUNCIL ACTION
The Environmental and Water Resources Departments recommends that the City Council pass and adopt Resolution No. 10930 - A Resolution Authorizing the City Manager to Execute an Agreement with Folsom Lake Ford for the Purchase of an eTransit Van.

BACKGROUND / ISSUE
The Environmental and Water Resources Department (EWR) recognizes the need to maintain a fleet of vehicles that will be able to provide reliable, efficient and responsive service. In coordination with the City of Folsom Fleet Manager, current department vehicles are reviewed to help identiff priority vehicles for replacement based on service life, mileage and purpose.

This agreement will facilitate replacement of a vehicle used by the by the Utility Maintenance Division that, based on this review, has exceeded its' expected service life in terms of age, mileage and ongoing maintenance costs.

This resolution authorizes the City Manager to execute an agreement with Folsom Lake Ford for the purchase of an eTransit van for a total amount of $66,362.28.

POLICY / RULE
Section 2.36.080 of the Folsom Municipal Code states, in part, that contracts for supplies, equipment, services, and construction with an estimated value of $66,141 or greater shall be awarded by the City Council.

I
MEETING DATE: 10t2512022
AGENDA SECTION: Consent Calendar
SUBJECT: Resolution No. 10930 - A Resolution Authorizing the Crty Manager to Execute an Agreement with Folsom Lake Ford for the Purchase of an eTransit Van
FROM: Environmental and Water Resources Department

Page 35 ends

10/25/2022 Item No.8.

Section 2.36.100(I) of the Folsom Municipal Code provides for a five percentprice differential to local bidders in contracting. This preference is only applied when quallty, service and other factors are equal.

ANALYSIS
Review of EWR vehicles identified a camera truck used by the Utility Maintenance Division as high priorrty for replacement. This vehicle is used for CCTV inspection of sewer laterals throughout Folsom and is therefore a critical piece of equipment for maintenance of the sewer infrastructure.

EWR staff coordinated with the Fleet staff to obtain quotes for the required vehicle. A summary of the bids received is shown in the table below. Folsom Lake Ford submitted the winning bid by virtue of local preference. With the local preference, the proposal from Folsom Lake Ford would have to be less than$67,178.51, which is within five percent of the lowest bid. Given that the proposal from Folsom Lake Ford is 566,362.28, this meets the local preference criteria.

The Environmental and Water Resources Department recommends that the City Council authorize the City Manager to execute an agreement with Folsom Lake Ford for the purchase of an eTransit van for a not-to-exceed amount of $66,362.28.

FINANCIAL IMPACT
Sufficient funds are budgeted and available in FY 2022-23 in the Sewer Operating Fund (Fund 530) for the requested vehicle purchase for a total price of $66,362.28 The replaced vehicle witl be sold in accordance with Folsom Municipal Code, section 2.36.220, Disposition of surplus personal property.

ENVIRONMENTAL REVIEW
This action is exempt from environmental review under the California Environmental Quality Act (CEQA).

ATTACHMENT
Resolution No. 10930 - A Resolution Authorinngthe City Manager to Execute an Agreement with Folsom Lake Ford for the Purchase of an eTransit Van 2 966,362.28Folsom Lake Ford
$67,212.43National Auto Fleet Group
$63,979.53Watsonville Fleet Group
Submitted,

Page 36 ends

10/25/2022 Item No.8.

Marcus Yasutake, Director

ENVIRONMENTAL AND WATER RESOURCES DEPARTMENT
J Page 37
10/25/2022 Item No.8.

RE,SOLUTION NO. 10930

A RESOLUTION AUTHORIZING THE CITY MANAGER TO EXECUTE AN

AGREEMENT WITH FOLSOM LAKE F'ORD FOR THE PURCHASE OF'AN

ETRANSIT VAN
WHEREAS, Environmental and Water Resources Department staff has validated the need to purchase an eTransit van based on an approved replacement schedule; and WHEREAS, this purchase has been competitively bid by three different vendors with Folsom Lake Ford submitting the winning bid by virtue of local preference identified under Folsom Municipal Code Section 2.36.100(I); and
WHEREAS, sufficient funds are budgeted and available in the Sewer Operating Fund (Fund 530); and
WHEREAS, replaced equipment will be sold in accordance with Folsom Municipal Code section 2.36.22},Disposition of surplus personal property; and WHEREAS, the agreement will be in a form acceptable to the City Attorney:

NOW, THEREFORE, BE IT RESOLVED that the City Council of the City of Folsom authorizes the City Manager to execute an Agreement with Folsom Lake Ford for the purchase of an eTransit van for a not-to-exceed amount of $66,362.28; PASSED AND ADOPTED this 25ft day of October,2\22,by the following roll-call vote:

AYES:

NOES:

ABSENT:

ABSTAIN:

Councilmember(s):

Councilmember(s):

Councilmember(s):

Councilmember(s):

Keni M. Howell, MAYOR
ATTEST:

Christa Freemantle, CITY CLERK
Resolution No. 10930

Page 1 ends

10/25/2022 Item No.8.
tiir,!!if-!:;t t I !...J!,ii
Folsom Crty Council
Staff rt

RE,COMMENDATION / COUNCIL ACTION
The Environmental and Water Resources Departments recommends that the City Council pass and adopt Resolution No. 10931 - A Resolution Authorizing the City Manager to Execute an Agreement with Dobbs Heavy Duty Holdings LLC, dba Dobbs Peterbilt for the Purchase of a Dump Truck and Appropriation of Funds.

BACKGROUND / ISSUE
The Environmental and Water Resources Department (ESIR) recognizes the need to maintain a fleet of vehicles that will be able to provide reliable, efficient and responsive service. In coordination with Fleet staff, current department vehicles are reviewed to help identifu priority vehicles for replacement based on service life, mileage and purpose. This agreement will facilitate replacement of a dump truck used by the Utility Maintenance division that, based on this review, has exceeded its' expected service life in terms of age, mileage and ongoing maintenance costs.

This resolution authorizes the City Manager to execute an agreement with Dobbs Heavy Duty Holdings LLC, dba Dobbs Peterbilt for the purchase of a dump truck in the amount of $301,010.94 and appropriation of funds.
1 MEETING DATE: r0t2512022
AGENDA SECTION: Consent Calendar
SUBJECT: Resolution No. 10931 - A Resolution Authorizing the Crty Manager to Execute an Agreement with Dobbs Heavy Duty
Holdings LLC, dba Dobbs Peterbilt for the Purchase of a Dump Truck and Appropriation of Funds
FROM: Environmental and Water Resources Department

POLICY / RULE

Page 39 ends

10/25/2022 Item No.9.

Section 2.36.120 of the Folsom Municipal Code states, in part, that contracts for supplies, equipment, services, and construction with an estimated value of $66,141 or greater shall be awarded by the City Council.

Section 2.36.170 of the Folsom Municipal Code permits cooperative purchasing agreements for the procurement of any supplies, equipment, service, or construction with one or more public procurement units in accordance with an agreement entered into or between the participants.

ANALYSIS
EWR staff coordinated with the Fleet staff to obtain a quote from Sourcewell, previously known as the National Joint Powers Agency, for the required vehicle. Sourcewell is a national cooperative purchasing entity of which the City of Folsom is a member. The City has purchased numerous items through Sourcewell.

Dobbs Heavy Duty Holdings LLC, dba Dobbs Peterbilt has a current contract with Sourcewell and provided a quote for the requested dump truck for a total of $301,010.94.

The Environmental and Water Resources Department recommends that the City Council authorize the City Manager to execute an agreement with Dobbs Heavy Duty Holdings LLC, dba Dobbs Peterbilt for the purchase of a dump truck for a total amount of $301,010.94.

FINANCIAL IMPACT
Dobbs Heavy Duty Holdings LLC, dba Dobbs Peterbilt has agreed to provide the dump truck for $301,010.94. There is a total of $199,940 available to replace sewer vehicles in the FY 2022-23 budget. An additional appropriation in the amount of $101,100 is required to purchase this vehicle. Staff proposes to transfer $101,100 from the Capital Replacement Fund (Fund 602) to the Sewer Operating Fund (Fund 530) as a transfer out from the Capital Replacement Fund.

The replaced vehicle will be sold in accordance with Folsom Municipal Code, section 2.36.220, Disposition of surplus personal property.

ENVIRONMENTAL REVIEW
This action is exempt from environmental review under the California Environmental Quality Act (CEQA).

ATTACHMENT
Resolution No. 10931 - A Resolution Authorizing the City Manager to Execute an Agreement with Dobbs Heavy Duty Holdings LLC, dba Dobbs Peterbilt for the Purchase of a Dump Truck and Appropriation of Funds
2

Page 40 ends

10/25/2022 Item No.9.

Submitted,
Marcus Yasutake, Director

ENVIRONMENTAL AND WATER RESOURCES DEPARTMENT
J

Page 41 ends

10/25/2022 Item No.9.

RESOLUTION NO. 10931

A RESOLUTION AUTHORIZING THE CITY MANAGER TO EXECUTE AN

AGREEMENT WITH DOBBS HEAVY DUTY HOLDINGS LLC, DBA DOBBS PETERBILT

FOR THE PURCHASE OF A DUMP TRUCK AND APPROPRIATION OF FUNDS WHEREAS, Environmental and Water Resources Department staff has validated the need to purchase a dump truck based on an approved replacement schedule; and WHEREAS, this purchase will be made through Sourcewell, which used its recognized cooperative purchasing agreement to award a contract to Dobbs Heavy Duty Holdings LLC, dba Dobbs Peterbilt in an amount not to exceed $301,010.94; and
WHEREAS, sufficient funds are available in the Sewer Operating Fund (Fund 530) and Capital Replacement Fund (Fund 602); and
WHEREAS, an appropriation will be required in the amount of $101,100 from the Capital Replacement Fund (Fund 602); and
WHEREAS, replaced equipment will be sold in accordance with Folsom Municipal Code section 2.36.220, Disposition of surplus personal property; and WHEREAS, the agreement will be in a form acceptable to the City Attomey:

NOW, THEREFORE, BE IT RESOLVED that the City Council of the City of Folsom authorizes the City Manager to execute an Agreement with Dobbs Heavy Duty Holdings LLC, dba Dobbs Peterbilt for the purchase of a dump truck in the amount of $301,010.94; BE IT FURTHER RESOLVED that the Finance Director is authorized to appropriate $ 1 01 ,1 00 in the Capital Replacement Fund (Fund 602) as a transfer to the Sewer Operating Fund (Fund 530) and to appropriate an expense and revenue in the Sewer Operating Fund (Fund 530) in the amount of $101,100.

PASSED AND ADOPTED this 25th day of October,2022, by the following roll-call vote:

AYES:

NOES:

ABSENT:

ABSTAIN:

ATTEST:

Councilmember(s):

Councilmember(s):

Councilmember(s):

Councilmember(s):

Christa Freemantle, CITY CLERK
Resolution No. 10931
Page I of I
Keni M. Howell, MAYOR

Page 42 ends

10/25/2022 Item No.9.
,i. Ij,ilnJl:r:\.:r
!,r j:!irr--rr+t l,r ).r, fi: l:

Folsom Crty Council
Staff ort
MEETING DATE: t012512022
AGENDA SECTION: Consent Calendar
SUBJECT Resolution No. 10932 - A Resolution Authorizing an Appropriation of Funds for The Mangini Ranch Phase I Re- Landscaping Project
F''ROM: Parks and Recreation Department

RECOMMENDATION / CITY COUNCIL ACTION
Staff recommends the City Council approve Resolution No. 10932 - A Resolution Authorizing an Appropriation of Funds for The Mangini Ranch Phase I Re-Landscaping Project.

BACKGROUND / ISSUE
On May 24fi, 2022, The State Water Board adopted new emergency water conservation regulations that were approved and put into action by the Office of Administrative Law on June 10, 2022. These new updated water restrictions enacted several new water conservation measures across the state, including the ban on watering non-functional turf. Pursuant to this, the City of Folsom stopped inigating turf that was deemed non-functional based on the State Water Boards definition. Since that time the City has received several calls regarding the lack of watering and dissatisfaction of the residents with the aesthetics of these areas. Historically, the City of Folsom has undertaken similar retrofit or conversation projects in areas where funding was available and intended for this use. The areas identified in Mangini Phase 1 are prime candidates for this sort of projects and meet both aforementioned requirements.

POLICY / RULE
In accordance with Chapter 2.36.090 (A)(1) and 2.36.120 of the Folsom Municipal Code, professional services are not subject to competitive sealed bidding requirements, and those costing $66,141 or greater shall be awarded by City Council. 1

Page 43 ends

10/25/2022 Item No.10.

ANALYSIS
The City currently has an agreement with BrightView Landscape Services to provide maintenance to the City's Landscaping and Lighting District, as well as to the Community Facilities District. Built into the referenced agreement are funds allocated for unscheduled services, the current years agreement (FY 2022-023) allows for $430,000 in unscheduled services. Funds to remove turf and replace with water wise plantings in the Mangini Ranch area was not anticipated atthe time of the agreement.

FINANCIAL IMPACT
Funds are currently available in the affected district's fund balances and will require an additional appropriation for the purpose of this project. The district breakdown is included below. The additional appropriation would be in the amount of $l13,267.86 in CFD 18 (Fund 288) and $27,849.68 in CFD 19 (Fund 289).

ATTACHMENT
L Resolution No. 10932 - A Resolution Authorizing an Appropriation of Funds for The Mangini Ranch Phase I Re-Landscaping Project

2. Proposals and Maps
Submitted,
Lorraine Poggione,
Parks & Recreation Director

1.09 $94,953.86Area 1: CFD 18 (FUND 288)

0.18 $18,314.00288Area2: CFD 18 (FI-IND
$27.849.680.4rArea 3: CFD l9 28e)

1.68 $141,117.54Total

Page 44 ends

10/25/2022 Item No.10.

Attachment I
Resolution 10932

Page 45 ends

10/25/2022 Item No.10.

RESOLUTION NO. 10932

A RESOLUTION AUTHORIZING AN APPROPRIATION OT'F'UNDS FOR THE MANGINI RANCH PHASE 1 RE.LANDSCAPING PROJECT
WHEREAS, staff has identified the need for re-landscaping of specific areas within Mangini Ranch Phase 1; and
WHEREAS, there are currently sufficient funds available in Community Facilities Districts CFD 18 and CFD 19 tund balances (FUNDS 288 &289); and WHEREAS, an additional appropriation will be required in the amount of $113,267.86 in CFD 18 (Fund 288) and $27,849.68 in CFD 19 ( Fund 289); and WHEREAS' the City of Folsom's existing agreement with BrightView Landscape Services allows for the use of these funds consistent with FMC Section 2.36; and NOW, THEREFORE' BE IT RESOLVED that the City Council of the City of Folsom authorizes the Finance Director to appropriate $113,267.86, to CFD 18 (FLIND 288) and 827,849.68 to CFD 19 (FUND 289) in the Fiscal Year 2022-23 operating budgets for these two funds to be used to re-landscape identified areas within Mangini Ranch Phase l. pASSED AND ADOPTED this 25ft day of October2022 by the following roll-call vote:

AYES:

NOES:

ABSENT:

ABSTAIN:

Councilmember(s):

Councilmember(s):

Councilmember(s):

Councilmember(s):

Keni M. Howell, MAYOR
ATTEST:

Christa Freemantle, CITY CLERK
Resolution No. 10932

Page 1 ends

10/25/2022 Item No.10.

Attachment 2

Page 47 ends

10/25/2022 Item No.10.

Brt4#g1;
Attachment 2
Proposals and Maps
Area l:

Prapolrl fsr Extrr Wort lt
cltl Ef Folrom
trptt6cr0C,fi2!
p+rdr
Ftqfarly
Frtpe.rty
ilarra
Adt€lt
nrydFoLq'l
Lighingt and Lendsd*e Csrtrsd
*EF glu gpllr6ct
FobonlCA S68S0
Ctrrtsd
To
Bfihglddt dB
J.it|llon Lei*tit
Cltf OtFolsaFraie wodE SltlE€l
O$iaon E0Hib{neSt
F&ncf. SsSd
Frqecittlone
tsoliFiBsiotdhn
Mmgtnl Fmpolsl l- Esst gldffill and Hsnglnl
nrrrr!6vr1 dn6i nE{tt Wrecn lha iltb End rldaiElk etd lqpl.ca rllth r$inzr{lii End butriloFnn€t
SsPr alllrotll
Prs$Ef,lng rrtrgg[i rqleg tir hll utidir th. {Fhalil miln|r}lrr.tc conlr*t.

Ew. llEllbr

ITO EIEH
fryhdrpr!!4Nnrqt
rm,-El{n
Pbdr*
t.40o Frcl{
ad!:m EA{:ll
rlrlr lfdob
30?,f,t EACII
ta rilhr. F.tdt
hrldl0rsr'idon
E1t lfulrt ldnlhid d f drpdt
Rrnml url lLpd rath (El HD $ow
&rEdlialbedr rrb dt-gle I l00o Fi!rcr
Jt4turrfihrf,Frl l0O
i'frmhll \rioar crnprf t FL BhrubPwlnil
hdhtrddlr elislbiiodte
}'nlFruE Bslitb I gd- sfttuBFltdtill lrublhd dllr
4 ena.r rFrg
ls*n*
.8in'*ruia
r${2AB
sfit00ma
130 T€ll.l fttdi
'rtts E nsr{il narolcE
nlt3mFaalr rotg llt lst om rilrs ffistl+pgcc tt corhidpr Erriartttir*tr*hn .}lt06i; &lob,Ad& CIE&rir * drilrrr116.b tDrS llr.rflt
t$tl"llB;86

Page 48 ends

10/25/2022 Item No.10.

Page 49 ends

10/25/2022 Item No.10.

Itta
4FEflldi*Fttfl.riyrtddtrr
Area2:
trnaie*fu AWrlforn il
ffAldFolmile
,fi@
!1
seitf,dilil
4rF.l!pf tflrf,t
oy u i+uqr,'fli riyriF erq3t
****ur,
6FF'"6'J{dEn,
,€t?Fq!"S-!et
!+1it
'F.rqPErfrtn
ftqtdFi4Fn;
rrryUir'g,qr"***ffOf re* "r'b*"tlr!t.

Rroord d @ nw tiilftqr fia qlb ald 1qa1 aU dlqE u.qt itrftb fi*utr
ihpCflrF
Fr.y*Fi. lbq'qF,{6,$[:r{d!fi *,Flt{d.tndt!hfir!9?,srySq, r{$ i$4*r
tgifni+i'n&t.t'0
:+r**gqin&{tg$Eig'tir!&. ;
l@ H*orr- rer rriyfi , {Om Flq rf,l
fuoqh$tnafr
&Sri*{rtdqt sd$hreftia*dridbritril:'iFDf'Q*tttE:.'. :
-rp*r.r*qw*rw'
' '$9' :'$,- ',trffi
,sn*: ,*fri81
,Tor.s[
*f.gg, :'W{.
'f.rirgtt'-a;*
rit ?*r{$o$
d* $ridt@,
r!*dtarl,ln $q. S{rltth. lt8.gtd.ilo
..:trFF rlil',$! rt$Elr
:
.
hribi ddrrrri gr*rt,rir rrgrlillar uye*riill-rlhfrit' rtrrror*rqlrqil*.3|nlllts+dHri|h.rt}#

Page 50 ends

10/25/2022 Item No.10.

Page 51 ends

10/25/2022 Item No.10.
l
Area 3:

Fruryod|rfsnf$m**
E&dFqlmm
.rQrhrnb{|"'li!!.
xi.t**
W
ruutrft!r0Fftis*bAdd'lc?
.slltilotd.tu*r
fhrcxrw mr$f'q$Fdd' :SF,i!'!g
ryiq,q+qryt. AryrEft qry*goyu*f$tr$tmrflqfsr Mqo ntrra*6lanm wd'lnns
ifiugtre,rugp ** b h'llcttds spnnrnl u;frdlrme {{t[h*.
qtutf FitFr
rt .ldreihO t*tOc{ori Grilrd
AtB-mrsra-ot
fidtrfi9fli86|00-i
cfi,tact sldLqsfi
Ta myoie,*;rtccrtwllsrr|[
'iniir .}ii*l;,
jlrfffil0[r ,Slllttii
$il,f.t$
f*nll: .*f;Sl:, i$ilr|(!,tbdiH.flf,!-o0F
;Fs{d bd 4*F{l ec! m ththil
,*tirH.hl lc{l * |.r* dl $|*l @[ftrlli'faiitdltidiiff"lm " tr{Wft*cr'{r'r TJ'Mi$ift{ Jtlf.si*ttrFtb','
,nrirrttilrird
,!.s.t 7sl{$tl
$f{ sJ1ffi*.rtlntniUir fae tfrleH$ lar,er$-rg
. . 'd#-Ell0rl44.ilrrXg
i
ri8 irhdr ufi bnl {iirirrr.utb ctr,.rf s|6tttirtbdtittrltiictidhil:-''--- - onttir*{iri S. [aritirrr* hnttrltt l- nt*[ru*

Page 52 ends

10/25/2022 Item No.10.

Page 53 ends

10/25/2022 Item No.10.

This page is intentionally trefr blank.

Page 54 ends

10/25/2022 Item No.10.

Folsom City Council
Staff Report
F()LSOl\[
MEETING DATE: 1012st2022
AGENDA SECTION: Consent Calendar
SUBJECT: Resolution No. 10933 - A Resolution Authorizing the City Manager to Execute AmendmentNo. 2 to the Professional
Services Agreement with Mintier Hamish and to Increase the Not- to-Exceed Amount for the Agreement for the Zoning Code Update Proiect
FROM: Community Development Department

RECOMMENDATION / CITY COUNCIL ACTION
Staff respectfully requests that the City Council approve Resolution No. 10933 - A Resolution Authorizing the City Manager to Execute Amendment No. 2 to the Professional Services Agreement with Mintier Harnish, which reallocates existing funds between existing tasks, authorizes the use of the contingency, and increases the total contract amount from $376,355 to $396,355 in order to allow the consultant to use the $20,000 contingency that was approved by City Council in ResolutionNo. 10237 on February 12,2019.

BACKGROUND / ISSUE
City staff and its consultant team (Mintier Harnish) are in the process of updating the City's Zoning Code, which has not been comprehensively updated for decades. As a result of many changes in State law since 2019, additional changes need to be made to the Zoning Code, which were not originally anticipated. Due to this additional work the $20,000 contingency that was established in Resolution No. 10237 on February 12,2019 is needed for the project. In addition, some tasks have taken more time compared to others. As a result, funds need to be reallocated among those tasks. When Council approved the use of State Local Early Action Planning (LEAP) grant funds for the Zoning Code Update in Resolution No. 10523, staff failed to increase the not-to-exceed amount to include the $20,000 contingency. As a result, the total not-to- exceed amount for the agreement should be increased from $376,355 to $396,355.

Page 55 ends

10/25/2022 Item No.11.

POLICY / RULE
They key 2035 General Plan policy that relates to the Zoning Code update is:
o LU 1.1.1 Ensure that the Folsom Zoning Ordinance is
consistent with the 2035 General Plan.

ANALYSIS
No analysis needed. Please refer to Background/Issue section.

FINANCIAL IMPACT
No financial changes are proposed as part of staff report as the funding for the $20,000 contingency was identified as part of Resolution No. 10237, and was funded in the Community Development Department budget.

ENVIRONMENTAL REVIEW
Under Section 15061(b)(3) of the California Public Resources Code, this activity will not have a significant effect on the environment and as such the project is exempt from environmental review under CEQA. Environmental review for the Zoning Code update will be conducted prior to the adoption hearings.

ATTACHMENTS

1. Resolution No. 10933 - A Resolution Authorizingthe City Manager to Execute AmendmentNo. 2 to the Professional Services Agreement with Mintier Harnish and to Increase the Not-to-Exceed Amount for the Agreement for the Zoning Code Update Project

2. Resolution No 10237 adopted February 12,2019

3. ResolutionNo. 10523 adopted September 8,2020
Submitted,
Pam Johns, Development Director

Page 56 ends

10/25/2022 Item No.11.

ATTACHMENT 1

Page 57 ends

10/25/2022 Item No.11.

RESOLUTION NO. 10933

A RESOLUTION AUTHORIZING THE CITY MANAGER TO EXECUTE
AMENDMENT NO. 2TO THE PROFESSIONAL SERVICES AGREEMENT WITH MINTIER HARNISH AND TO INCREASE THE NOT.TO.EXCEED AMOUNT FOR

THE AGREEMENT FOR THE ZONING CODE UPDATE PROJECT
WHEREAS, the City Council adopted the2035 General Plan on August 28,2018, which set forth new goals and policies for future development and required in Policy LU 1.1.1 that the City's Zoning Ordinance be consistent with the General Plan; and WHEREAS, the City Council approved ResolutionNo. 10237 on February 12,2019 authorizing the City Manager to execute a professional services agreement with Mintier Harnish for the comprehensive update of the City's Zoning Code and to establish a $20,000 contingency for the project; and
WHEREAS, the California State Legislature in its 2019-2020 session enacted a number of new laws designed to increase affordable housing supply and, as a result, required additional update to the Ctty's Zoning Code; and
WHEREAS, the City Council approved ResolutionNo. 10424 on April 28,2020,which authorized the City Manager to apply for $300,000 from the State's Local Early Action Planning (LEAP) grant program to fund several efforts to improve the zoning and development review process in Folsom including additional Zoning Code work; and WHEREAS, on Augustl0,2020, the City received an award letter from the State Housing and Community Development Department for $300,000 from the LEAP grant program; and
WHEREAS, the extra zoning code work needed to address the additional State mandates and provide for additional outreach and education was $47,000; and WHEREAS, Resolution No. 10523 added the $47,000 and increased contract amount from $329,355 to $376,355, but this amount did not include the $20,000 contingency originally established in ResolutionNo. 10237; and
WHEREAS, additional State laws approved in 2021 and2022 require additional analysis in the Zoning Code that was not anticipated; and
WHEREAS, this additional work requires the use of the $20,000 contingency that was established in Resolution No. 10237 and as a result the new total not-to-exceed amount should be increased to $396,355; and
WHEREAS, approval of the amendment and the allocation of funding is exempt from the California Environmental Quality Act (CEQA):

ResolutionNo. 10933
Page I of2 Page 58
10/25/2022 Item No.11.

NOW' THEREFORE, BE IT RESOLVED thatthe City Manager is hereby authorized to execute Amendment No. 2 to the Consultant and Professional Services Agreement with Mintier Harnish for the Zoning Code Update project and allow the use of the contingency for a total not-to-exceed amount of $396,355, in a form acceptable to the City Attorney.

PASSED AND ADOPTED onthis 25ft day of October 2022,by the following roll-call vote:

AYES:

NOES:

ABSENT:

ABSTAIN:

Councilmember(s)
Councilmember(s)
Councilmember(s)
Councilmember(s)
ATTEST:

Christa Freemantle, CITY CLERK
ResolutionNo. 10933
Page2 of2
Kerri M. Howell, MAYOR

Page 59 ends

10/25/2022 Item No.11.

ATTACHMEI{T 2

Page 60 ends

10/25/2022 Item No.11.

RESOLUTION NO. 10237

A RESOLUTION AUTTIORIZING THE CITY MANAGER TO EXECUTE A

PROFESSIONAI, SERVICES AGREEMENT WITH MINTIER HARNISH FOR THE ZONING CODE UPDATE; ACCEPT A SACOG COMMUNITY DESIGN GRANT AWARD; AND APPROVE A F'Y 2018-19 MID-YEAR BUDGET UPDATE TO THE

COMMUNTTY DEVELOPMENT DEPARTMENT AND APPROPRIATION OF FUNDS WI{EREAS, the City Council adopted the2035 General Plan on August 28,2018, which set forth new goals and policies for future development and required in Policy LU 1.1.1 that the City's Zoning Ordinance be consistent with the General Plan; and WIIEREAS, the City's ZoningOrdinance has not been comprehensively updated in many decades; utd
WHEREAS, the City issued a request for proposals on October 15, 2018 seeking consultant assistance with the Zoning Ordinance update. Four proposals were received and interviews were conducted. A team lead by Mintier Harnish recommended by staff given their extensive experience with preparing Zoning Ordinances; and WHEREAS, the City has applied for and was awarded a Community Design Grant in the amount of $i00,000 from the Sacramento Area Council of Governments (SACOG), and requires a match of at least $i0,000. The grant is to be used to update the portions of the City's Zoning Ordinance that address mixed-use developrnent along the East Bidwell Corridor in accordance with the 2035 General Plan; and
WIIEREAS, the total cost of the scope of work frorn Mintier Harnish is $329,355.

Given that the effort is expected to take one to two years, it is not usual for additional issues to come up that may require additional research or additional outreach. Staff requests an additional $20,000 be included in the budget for this project as contingency to address any unforeseen issues, for a total not to exceed amount of $349,3 55 for this project.

WHEREAS, the total cost for the Zoning Ordinance update including the contingency is $349,355 and the City has secured $100,000 from SACOG and the FY 2018-19 budget included $100,000 for the for the zoning update an additional $i49,355 is needed to authorize the agreement with Mintier Harnish.

WHEREAS, The Community Development Department has incurred other costs that were not anticipated when the FY 2018-19 budget was developed, staffis requesting an additional appropriation in the amount of $110,645 which would be offset by building permit revenue.

W1IEREAS, approval of the agreements and the allocation of funding is exempt from the California Environmental Quality Act (CEQA)'
NOW, TIIEREFORE, BE IT RESOLVED thatthe City Council of the City of Folsom:

Resolution No, 10237
Page I of3

Page 61 ends

10/25/2022 Item No.11.

1. Authorizes the City Manager as part of the City's implementation of the 2035 General Plan, to execute a Consultant and Professional Services Agreement with Mintier Harnish for the Zoning Code Update in the amount of $329,355, with the budgeted amou:t to include a $20,000 contingency for a total not-to-exceed amount of $349,355, in a form acceptable to the City Attorney; and NOW THEREFORE, BE IT FURTIIER RESOLVED that the City Council of the City of Folsom:

2. Approves the acceptance of a SACOG Community Design grant in the amount of $100,000:

3. Authorizes the City Manager to execute a Memorandum of Understanding between the Sacramento Area Council of Governments and the City of Folsom in a form acceptable to the City Attorney; and

4. Authorizes the Chief Financial Officer to increase revenue estimates and expenditure appropriations by $360,0A0: $249,355 for the Zoning Code update and $1 10,645 tc adjust cuffent year expense and revenues based on the following findings:

GENER,AL FINDINGS
GENERAL PLAN POLICY LU 1 .1.I STATES THAT THE CITY SHALL ENSURE 'THAT THE FOLSOM ZONING ORDINANCE IS CONSISTENT WITH THE POLICIES AND PROGRAMS OF THE GENERAL PLAN.

A COMPREHENSIVE ZONING ORDINANCE UPDATE IS REQUIRED TO ENSURE

CONSISTENCY WITH THE GENERAL PLAN, PROVIDE CLARITY, AND DELIVER CLARITY TO RESIDENTS, BUSINESSES AND DEVELOPERS ALIKE.

TI{E CITY iSSUED A REQ1JEST F'OR PROPOSALS AND BASED ON ITS

EVALUATION, STAFF RECOMMENDS THE TEAM OF MINTIER HARNISH AS

THE MOST RESPONSIVE AND QUALIFIED CONSULTANT TO PREPARE THE ZONING CODE UPDATE.

D IN ORDER TO FLIND PART OF THE ZONING CODE UPDATE CITY APPLIED FOR AND RECEIVED A COMMTINITY DESIGN GRANT FROM SACOG.

COLINCIL APPROVAL iS REQUIRED TO ACCEPT AND RECEIVE THE GRANT FUNDS.
g$Q$, nrFJprNGs
rN ACCORDANCE WrTH CEQA GUIDELINES SECTTON 1s061(b)(3), APPROVAL

OF A CONSULTANT CONTRACT, ACCEPTANCE OF THE GRANT FROM

SACOG AND APPROVAL OF THE AGREEMENT WITH SACOG IS NOT A PROJECT TINDER CEQA AND IS EXEMPT FROM ENVIRONMENTAL REVIEW.

Resolution No. i0237

Page 2 ends

A.

B.

C.

A.

Page 62 ends

10/25/2022 Item No.11.

PASSED AND ADOPTED on this 12d'day of February 2019, by the following roll-call vote:

AYES:

I\OES:

ABSENT:

ABSTAIN:

Council Member(s):

Council Member(s):

Council Member(s):

Council Member(s):

Kozlowski, Sheldon, Aquino, Gaylord, Howell
None
None
None
Lydia DEPUTY
Resolution No. 10237

Page 3 ends
Page 63 ends

10/25/2022 Item No.11.

ATTACHMENT 3

Page 64 ends

10/25/2022 Item No.11.

RESOLUTION NO. 10523

A RESOLUTION AUTHORIZING THE CITY MANAGER TO EXECUTE
AMNI\DMENT NO. 1 TO TIM PROX'ESSIONAL SERVICES AGREEMENT WITH

MINTIER IIARNISH FOR ADDITIONAL TASKS FOR THE ZONING CODE UPDATE; AI\D APPROPRIATION OF FUNDS
WHEREAS, the City Council adopted the 2035 General Plan on August 28,2018, which set forth new goals and policies for future development and required in Policy LU

1.1.1 that the City's ZonngOrdinance be consistent with the General Plan; and WHEREAS, the City Council approved ResolutionNo.10237 onFebruary 12,2019, authorizing the City Manager to execute a professional services agreement with Mintier Hamish for the comprehensive update of the Crty's Zorung Code; and WHEREAS, the Califomia State Legislatt[e in its 2019-2020 session enacted a number of new laws designed to increase affordable housing supply and, as a result, requires additional update to the City's Zonng Code; and
WHEREAS, the City Council approved Resolution N o. 10424 on April 28, 2020, which authorized the City Manager to apply for $300,000 from the State's Local Early Action Planning (LEAP) grant program to firnd several efforts to improve the zoning and development rwiew process in Folsom including additional Zonng Code work; and WHEREAS, on Augustl},Z}2},the City received an award letter from the State Housing and Community Development Departnent for $300,000 from the LEAP grant program; and
WHEREAS, the total cost of the original scope of work from Mintier Harnish was $329,355. The additional tasks needed to address the additional State mandates and provide for additional outreach and education is $47,000 for a total not to exceed amount of $376,355 for this project; and
WHEREAS, the additional grant amount of $253,000 will be utilized for additional ZontngCode updates, equipment and technology for inspections, GIS work for the Zontng Code and Housing Elenr-ent updates, and permitting and a nexus study for development fees; and
WIIEREAS, approval of the amendment andthe allocation of funding is exempt from the CalifomiaEnvironmental Quality Act (CEQA):

NOW, TIIEREFORE, BE IT RESOLVED that the City Manager is hereby authorized to execute Amendment No. I to the Consultant and Professional Services Resolution No. 10523
Page I of2

Page 65 ends

10/25/2022 Item No.11.

Agreement with Mintier Harnish for the ZonngCode Update in the amount of $47,000 for a total notto-exceed amount of $376,355, in a fonn acceptable to the City Attomey' BE IT X'URTHER RESOLVED that the Finance Director is hereby authorized to appropriate an additional $300,000 to the General Fund (Fr:nd 010) in the Community tievetopment Departnent, $47,000 for the additional tasks for the Zoning Code update and the remainder for additional tasks as set forlh in ResolutionNo. 10424. pASSED AliD ADOPTED this 8ft day of September2}2l,by the following roll-call vote:

AYES:

NOES:

ABSENT:

ABSTAIN:

Aquino,
ATTEST:

Freemantle, CITY CLERK
Resolution No. 10523
Page2 of?
Council Member(s):

Council Member(s):

Council Member(s):

Council Member(s):

Howell, Kodowski, Morin, Aquino
None
Sheldon
None

Page 66 ends

10/25/2022 Item No.11.
i i i 'r; l li
i: rr:.!i.!|i9 l.,.,li ,
Folsom City Council
Staff Re

RECOMMENDATION / CITY COUNCIL ACTION
The Fire Department recommends that the City Council move and adopt Resolution No. 10934 - A Resolution Authorizingthe City Manager to Execute a Purchase Agreement with Golden State Fire Apparatus Inc. for One Type 3 Fire Engine.

BACKGROI ]ND / ISSIIE
Fire engines are the front line vehicles used by the Fire Department to carry hose, water, tools, and the pump to extinguish fires. The Fire Department requires an additional Type 3 fire engine for Station 34. The Type 3 fire engine is specifically designed to respond to wildland fires. This purchase was approved in the Folsom Capital Improvement Plan in the Fiscal Year 2022-23 Budget. This fire engine will take approximately thirteen months to build with an estimated delivery date of November 2023.

Staff is recommending that the City of Folsom enter into a cooperative purchase agreement with Golden State Fire Apparatus Inc. of Sacramento, California using the Houston-Galveston Area Council Cooperative Purchasing Program (HGACBuy) to purchase one Type 3 fire engine. The total price to purchase this fire engine is $482,4943.88.

I
MEETING DATE: t0/2512022
AGENDA SECTION: Consent Calendar
SUBJECT: Resolution No. 10934 - A Resolution Authorizing the City Manager to Execute a Purchase Agreement with Golden State Fire Apparatus Inc. for One Type 3 Fire Engine
FROM: Fire Department

Page 67 ends

10/25/2022 Item No.12.

POLICY / RULE
Folsom Municioal Code" Section 2.36.170, Cooperative Purchasing, describes the procedures to *t"t itrto a cooperative purchase agreement with another public agency for the procurement of supplies, equipment, or service.

Section 2.36.0g0, Award of Contracts of the Folsom Municipal Code states, in part, that contracts for supplies, equipment, services, and construction with an estimated value of $66,141 or greater shall be awarded by Crty Council'

ANALYSIS
The Fire Department currently operates two Type 3 fire engines daily, and J]r]s addition will provide the Folsom plan Area with wildland fire protection. The current wildland fire engine heet is assigned at fire stations outside the Folsom Plan Area and provide the city with wildland fire protection.

The Fire Department has conducted extensive research and determined that cooperative purchase through the Houston-Galveston Area Council Cooperative Purchasing Program iUCeCnny) wiuld provide the City of Folsom with the best product at the best price' ifCACe"y has for i0 y..r assisted local government members nationally in reducing competitive bid costs associated with procuring products and services. There are several Caliiomia municipalities who participate in the HGACBuy program. They include the Cities of Auburn, Roseriille, Rancho Cordova, Sacramento, Vacaville and Woodland. The County of Sacramento and the Sacramento Metropolitan Fire District are also participants in the program.

Golden State Fire Apparatus Inc. has been awarded a contract through HGACBuy to supply fire apparatus on behalf of BME Fire Trucks LLC. The City of Folsom will save an additional 5o/o over the lowest bid price that Golden State Fire Apparatus Inc. can offer by utilizing HGACBuy. The City Attorney's office has reviewed the HGACBuy process and determined its use to be consistent with City Policy'
This purchase would add additional fire protection to the Folsom Plan Area. This engine would be a tasic, Type 3, full size fire engin-. It would be equipped with seating for four, a five hundred gallon water tank, a 500 gallon per minute pump, and all required loose equipment.

It wouldiespond as a front line apparatus on grass fires, wildland fires and state mutual aid requests.
2 Page 68
10/25/2022 Item No.12.

F'INANCIAL IMPACT
The Fiscal Year 2022-23 budget includes $482,494.88 in the Folsom Plan Area Impact Fund (Fund 472) for the purchase of the fire engines and the necessary standard equipment for Fire Station 34.

ENVIRONMENTAL REVIEW
This action is not considered a project under Section 15061(b)(3) of the California Environmental Quality Act Guidelines, and as such is exempt from environmental review.

ATTACHMENTS

1. ResolutionNo. 10934 - A Resolution Authorizing the City Manager to Execute a Purchase Agreement with Golden State Fire Apparatus Inc. for One Type 3 Fire Engine.

2. Product Proposal from Golden State Fire Apparatus Inc.

Submitted,
Ken Cusano, Fire Chief
J
One BME F ire 4X4 International 3 Model34 $397,099.93
C contract number FSl2-17
Discount For 100% at Time of Order $8,013.73
Fire $48,573.66
Performance Bond $3,618.75
One 1 F $3,963.00
lDealer $2,800.00
Total Cost $448,041.61
Sales Tax @7.75%
California Tire Fee
s34,442.77
$10.s0
Total Enqine Cost to Cify of Folsom $482,494.88

Page 69 ends

10/25/2022 Item No.12.

Attachment 1
Resolution No. 10934 - A Resolution Authorizingthe City Manager to Execute a Purchase Agreement with Golden State Fire Apparatus Inc. for One Type 3 Fire Engine.

Page 70 ends

10/25/2022 Item No.12.

RESOLUTION NO. 10934

A RESOLUTION AUTHORIZING THE CITY MANAGER TO EXECUTE A
PURCHASE AGREEMENT WITH GOLDEN STATE FIRE APPARATUS INC. F'OR ONE TYPE 3 FIRE ENGINE.

WHEREAS, the Fire Department staff has completed extensive research and validated the need to acquire an additional Type 3 fire engine; and WHEREAS, one Type 3 fire engine was approved in the Capital Improvement Plan in the Fiscal Year 2022-23 Budget; and,
WHEREAS, staff reviewed and recommended participation in a cooperative purchasing agreement with the Houston-Galveston Area Council utilizing Golden State Fire Apparatus Inc., fJr purchase ofa new fire engine to ensure purchase ofthe best product at the best price; and, WHEREAS, staff complied with the provisions of Folsom Municipal Code Section

2.36.170; and,
WHEREAS, Golden State Fire Apparatus will manufacture, supply, and deliver one Type 3 fire engine meeting the Fire Department's specifications for a total sum of $482,494.88; and WHEREAS' sufficient funds are budgeted and available in the Folsom Plan Area Improvement Fund (Fund 472) for the Type 3 engine for Station 34 in the amount of $482,494.88; and
WHEREAS, the agreement will be in a form acceptable to the City Attorney; NOW, THEREFORE, BE IT RESOLVED by the City Council of the City of Folsom that the City Manager is authorized to execute a purchase agreement with Golden State Fire Apparatus Inc., for one Type 3 fire engine, in the amount of $482,494.88. pASSED AND ADOPTED on this 25ft day of October,2022, by the following roll-call vote:

AYES:

NOES:

ABSTAIN:

ABSENT:

Councilmembers:

Councilmembers:

Councilmembers:

Councilmembers:

ATTEST:

Christa Freemantle, CITY CLERK
Resolution No. 10934

Page 1 ends

Keni M. Howell, MAYOR

Page 71 ends

10/25/2022 Item No.12.

Attachment 2
Product Proposal from Golden State Fire Apparatus Inc.

Page 72 ends

10/25/2022 Item No.12.

FIRE TRUCKS

PRODUGT

PROPOSAL
Exhibit t'Att

Page 73 ends

10/25/2022 Item No.12.

PROPOSAL PREPARED FOR
CiW of Folsom Fire DePartment
BME Fire Trucks, LLC.
4X4 lnternational Type 3 Model 34
Engine, item # W3-M34D-1
October t0,2022

SALES CONSULTANT
Ryan Wright
Golden State Fire Apparatus, lnc.
7400 Reese Road
Sacramento, CA 95828
209.613.3809 Cell
rvan@goldenstatef ire.com

PARTS, SERVICE & SUPPORT
Golden State Emergency Vehicle Service, lnc.
7400 Reese Road
Sacramento, CA 95828
915.330.1638 Office
[email protected]

Page 74 ends

10/25/2022 Item No.12.
7400 Reese Road
Sacramento. CA 95828
Office 916.330.1638
Fax 916.330.1649

FIRE APPARATUS
PROPOSAL PREPARED FOR:

City of Folsom Fire DePartment
535 Glenn Drive
Folsom, CA 95630
We hereby propose and agree to furnish, after your acceptance of this proposal and the proper execution by the CITY OF FoLSOM FiRE bEPARTMiNT, hereinafter called "Customer" and an officer of Golden State Fire Apparatus, lnc', hereinafter call"d lGSFtrJh" f"llo*ing fir" apparatus and equipment, hereinafter called "Product":

October 70,2022Submitted Date:
97010-22Proposal Number:

Ryan WrightSales Consultant:

Expiration
Date: October 31, 2022
397,099.93A
Type w3-#34Model itemneEnnte narnatio 3FireE LLC 4X4 greOn 1 M Trucks,B( ) 1No. 1-22-23-2ContractStafe34D-M 1 FIRE
48,573.66B Fire Fi
3,963.00c One 1 F Final FFD
2,800.00D Delive / Dealer
(8,013.73)E t Discount for 100% at Time of Order
444,422.86F SUBTOTAL
34,442.77G 7.75o/o State Sales Tax

10.50H California Tire Fee
3,618.75100% Performance Bond
J 482,494.88GRAND TOTAL
Descr.iption# Unit Price

PROPOSAL SUMMARY
This proposal includes the following items in accordance with the specifications hereto attached:
. Fire apparatus and equipment
. Pre-delivery inspection/services by GSFA

PRODUCT COMPLETION
product shall be built in accordance with the specifications hereto attached, delays due to acts of God, strikes, war' or intentional conflict, failures to obtain chassis, materials, unusual weather conditions or other causes beyond GSFA's control not preventing, within approximately 5g5 to 775 CALENDAR DAYS after receipt of this order and the acceptance thereof at ou, br.r.r"n-to, California orfce. wittrin *''my (go) calendar days after receipt of this order and acceptance thereof, GSFA shall submit to Customer a production schedule including tentative pre-construction conference, final inspection and final delivery dates.

DELIVERY LOCATION
product shall be shipped in accordance with the specifications hereto attached and be delivered to you at FOLSOM.

CALIFORNIA. proof of insurance must be demonstrated by the Customer to GSFA prior to transferring of the Product(s). . Delivery to GSFA service center in Sacramento
. Final delivery from service center to Customer

Page 2 of 3 ends
Page 75 ends

10/25/2022 Item No.12.

ACCEPTI NG TH IS PROPOSAL
ln the event Customer wishes to purchase the Product described in this Proposal and the attached specifications, then, prior to the expiration date listed on page Z oi this proposal, Customer shall sign and return this Proposal. Thereafter, GSFA and Customer will endeavor to enter into a purchase agreement incorporating this Proposal and including additional terms (a "Purchase Agreement"). lf Customer returns a signed copy of this proposal alone, GSFA will send Customer its form of Purchase Agreement for Customer's review and signature. lf Cusiomer desires to use its standard form of purchase order as the Purchase Agreement, then Customer should return a signed copy of this proposal along with a copy of such purchase order. All purchase orders shall be made out to GSFA. GSFA will review such purchase order and contact the Customer regarding any required revisions. Only upon a full execution of a Purchase Agreement shall GSFA and Customer be obligated to purchase and sell the Product set forth in this Proposal.

TERMS AND CONDITIONS
The following Terms and Conditions are hereby made part of this Proposal:

1. Payment Terms (100% Pre-Payment at Time of Order) - Customer shall pay the amount listed on page one of this Proposal, which includes: (i) the total price for the Product (the "Purchase Price"), (ii) the estimated state sales tax on the Product, and (iii) the California tire fee (together with the Purchase Price and estimated state sales tax, the "Grand Total") within fifteen (15) calendar days from the date on which the Purchase Agreement is fully executed. The proposed delivery timeframe for the Product, which is outlined on page one ofthis Proposal, shall not begin until full payment of the Grand Total is received. ln the event Customer does not pay GSFA the Grand Total in the timeframe set forth in this Section 1' GSFA may, in its sole discretion, cancel the Purchase Agreement entered into between the parties.

2. Commercial Chassis Price Volatllity - GSFA shall not be responsible for any commercial chassis price increase or surcharge enacted by a commercial chassis Original Equipment Manufacturer (oEM) after the execution of contract or issuance of Purchase Order. Any commercial chassis price increase or surcharge will be passed through to the customer at cost and will be documented in writing on a Change Order. Customer shall pay any commercial chassis price increase or surcharge prior to final delivery or pick up to Customer location.

3. Stock / Demo Units - lf applicable, any stock/demo units, including those identified by this Proposal, are available for sale on an as-is, first- come and first serued-basis. Regardless of this Proposal, the first Customer to enter into a Purchase Agreement identifying any such stock/demo unites shall obtain said units'
Ryan Wright
Golden State Fire Apparatus, lnc.
7400 Reese Road, Sacramento, CA 95828 | Office 916.330.1638 | Fax 975.330.7649

5. Force Majeure - GSFA shall not be responsible nor deemed to be in default on account of delays in performance due to causes which are beyond GSFA's and manufacturer's control and which make GSFA's performance impracticable, including but not limited to wars, insurrections, strikes, riots, fires, storms, floods, other acts of nature, explosions, earthquakes, accidents, any act of government, delays in transportation, inability to obtain necessary labor supplies or manufacturing facilities, allocation regulations or orders affecting materials, equipment, facilities or completed products, failure to obtain any required license or certificates, acts of God or the public enemy or terrorism, failure of transportation, epidemics, quarantine restrictions, failure of vendors (due to causes similar to those within the scope of this clause) to perform their contracts or labor troubles causing cessation, slowdown, or interruption of work.

6. Cancellation/Termination - ln the event Customer and GSFA enter into a Purchase Agreement and Customer thereafter cancels or terminates the Purchase Agreement, GSFA will charge a cancellation fee as follows: (a) 10% of the Purchase Price after order is accepted and entered by GSFA; (b) 20% of the Purchase Price after completion of the pre-construction phase of the order process; and (c) 50% of the Purchase Price after the requisition of any materials or commencement of any manufacturing or assembly of the Product by either GSFA or the manufacturer of the Product. The tier of cancellation fee applicable to any cancellation shall be in the sole and absolute discretion of GSFA.

7. State Sales Tax - Customer shall be responsible for the cost of state sales tax associated with, or attributable to the Product' The taxes owed by Customer for the Product is subject to adjustment for the applicable state sales tax rate in effect when the Product is delivered to the Customer. Therefore, the sales tax will be increased or decreased at the time of delivery if a change in the sales tax rate has occurred, in which case Customer shall pay GSFA (or be refunded by GSFA) the applicable change in sales tax.

8. Proposal Explration - After the Expiration Date shown on page one of this Proposal, Customer shall require G5FA's written consent to accept this Proposal.

9. Governing Law - This Proposal is to be governed by and under the laws of the state of California.

4. Order Changes - The Customer may request that GSFA incorporate a change to the Product or the Specifications for the Product by delivering a written change order to GSFA, which shall include a description of the proposed change sufficient to permit GSFA to evaluate the feasibility of such change (a "Change Order"). GSFA will provide Customer a written response (a "Response") stating (i) whether GSFA will accommodate such Change Order (which GSFA may decide in its sole and absolute discretion) and (ii) the terms of the modification to the order, including any increase or decrease in the Purchase Price resulting from such Change order' and any effect on production scheduling or Delivery resulting from such Change Order. Customer shall have seven (7) days after receipt of the Response to notify GSFA as to whether Customer desires to make the changes GSFA has approved in the Response. ln the event Customer counter-signs GSFA's Response, Customer shall pay the increase (or be refunded the decrease) in the Purchase Price prior to final delivery to Customer location.

Thank you for providing Golden State Fire Apparatus, lnc. with the opportunity to provide this proposal. lf you have any questions regarding the options presented or need additional options, please contact me. r authorized
i"pr"t*tr1i"".icrrY oFF-oGoMFrnE orpnnrvrNr asrees to purchase the proposed Product(s) and agree to the terms and conditions of this proposal and the specif ications hereto attached.

SIGNATURE:

Page 3 of 3 ends
Page 76 ends

10/25/2022 Item No.12.

FIRE TRUCKS

PRODUGT

SPEGIFIGATIONS
Exhibit 33B"

Page 77 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus

FIRE TRUCKS

FOLSOM FIRE

DEPARTMENT
''CAL-FIRE'' MODEL 34
1 0030-0002
Pagel o172
10t10t22

Page 78 ends

10/25/2022 Item No.12.

Golden State Fire ApParatus
*SPBCIFICATIONS ARE SUBJECT TO CHANGE PENDING ENGINEERING*

DETERMINATION OF APPARATUS WEIGIIT
BME Fire Trucks, LLC. shall submit estimated "in-service" weight analysis required by applicable NFPA standards. This Excel computer weight analysis shall break down all major components of the apparatus and shall show the impact on percentage-of-load on the front and rear axles, total weight, and weight on each tire set.

The analysis shall evenly distribute the NFPA required minimum payload allowance or estimated equipment payload as provided by the purchaser into the specified compartments. The allowance for personnel, hose loads, water and foam fluids, and required NFPA equipment shall be outlined individually in the analysis and placed on the apparatus in its specific intended position'
CENTER.OF-GRAVITY ANALYSIS
BME Fire Trucks, LLC. shall perform an estimated center of gravity calculation as required by the applicable section of NFpA standards. This calculation shall include tilt angles, the estimated right to left load distribution, and load on each axle, including all specified major components.

LOW VOLTAGE TEST REOUIRMENTS
The fire apparatus low voltage electrical system shall be tested as required by this section and the test results shall be
"ittin.O
by the apparatus manufacturer. The ceftification shall be delivered to the purchaser with the documentation for the completed apparatus. The tests shall be performed when the air temperature is between 0 degrees Fahrenheit and I 10 degrees Fahrenheit.

TEST SEOUENCE
The three tests defined below shall be performed in the order in which they appear. Before each test, the chassis batteries shall be fully charged until the voltage stabilizes at the voltage regulator set point and the lowest charge current is maintained for 10 minutes. The failure of any of these tests shall require a repeat of the test sequence'

RESERVE CAPACITY TEST
The chassis engine shall be started and kept running until the chassis engine and engine compartment temperatures are stabili zed atnormal operating temperatures and the chassis battery system is fully charged' The chassis engine shall be shut off and the minimum continuous electrical load shall be applied for 10 minutes. All electrical loads shall be turned off prior to attempting to restart the chassis engine. The chassis battery system shall then be capable of restarting the chassis engine. The failure to restart the chassis engine shall be considered a failure of this test.
1 0030-0002
Page2 of 72
10t10122

Page 79 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus

ALTERNATOR PERFORMANCE TEST AT IDLE
The minimum continuous electrical load shall be applied with the chassis engine running at idle speed. The chassis engine temperature shall be stabilized at normal operating temperature. The chassis battery system shall be tested to detect the presence of a chassis battery cument discharge. The detection of chassis battery cument discharge shall be considered a failure ofthis test.

ALTERNATOR PERFORMANCE TEST AT FULL LOAD
The total continuous electrical load shall be applied with the chassis engine running up to the engine manufacturer's govemed speed. The test duration shall be a minimum of two hours. The activation of the electrical system load management system shall be permitted during this test. The activation of an alarm due to excessive chassis battery discharge, as detected by the system required by NFPA (current edition), or an electrical system voltage of less than 11.8 volts direct current for a12 volt direct current nominal system, for more than 120 seconds, shall be considered a failure of this test.

LOW VOLTAG AI,ARM TEST
Following the completion of the tests described above, the chassis engine shall be turned off. With the chassis engine turned off, the total continuous electrical load shall be applied and shall continue to be applied until the excessive battery discharge alarm activates. The chassis battery voltage shall be measured at the battery terminals.

The test shall be considered to be a failure if the low voltage alarm has not yet sounded 140 seconds after the voltage drops to 11.70 volts direct current for a 12 volt direct current nominal system. The chassis battery system shall then be able to restart the chassis engine. The failure of the chassis battery system to restart the chassis engine shall be considered a failure of this test.

The completed fire apparatus shall undergo a complete 12 volt electrical load and performance testing per applicable sections of NFPA standards with inspection and test sheets included in delivery documentation.

DOCUMENTATION
The apparatus manufacturer shall provide the results of the low-voltage electrical system performance test, certified in writing, with the documentation provided to the purchaser at the time of delivery of the completed apparatus.

The test results shall consist of the following documents (l) Documentation of the electrical system performance tests. (2) A written electrical load analysis, including the following:
. (a) The nameplate rating of the altemator.
1 0030-0002

Page 3 of 72 ends

10t10t22

Page 80 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
. (b) The alternator rating under the conditions specified in NFPA 1906 (cunent edition). . (c) Each of the component loads specified that make up the minimum continuous electrical load. . (d) Additional electrical loads that, when added to the minimum continuous electrical load, determine the total continuous electrical load.
. (e) Each individual intermittent electrical load.

TEST RI,SULTS
BME Fire Trucks LLC. shall provide results of the apparatus testing and shall certify the following:

The weight of the completed apparatus, when loaded to it's estimated in service weight, does not exceed the GVWR and GAWR of the chassis.

The complete unit, when loaded to its estimated in service weight, meets the weight distribution and vehicle stability requirements, as defined in the curent NFPA guidelines.

The unit meets all required federal standards pertaining to the manufacturer and completion of the apparatus and a label tag has been affixed to the apparatus by the manufacturer stating same.

BME Fire Trucks LLC. shall provide all testing results, including engine, speed, acceleration, road ability, braking, and auxiliary braking to the Purchaser at the time of delivery'

DELIVERY REOUIREMENTS
The bidder shall not be responsible for delays in delivery due to strikes, acts of God, failure of suppliers to deliver, chassis shortage and other reasons beyond the reasonable control of the builder. Should BME Fire Trucks, LLC. be unable to comply with the proposed delivery date, we shall immediately contact the purchaser regarding delay information and actions to be taken by the company.

This vehicle shall be F.O.B. the BME Fire Trucks facility in Boise Idaho. Dealer shall be responsible for arrangement of delivery from factory.

GENERAL WARRANTY PROVISIONS
All materials and workmanship herein specified, including all equipment furnished, shall be guaranteed for a period of one (l) year after the acceptance date of the apparatus, unless otherwise noted, with the exception of any normal maintenance services or adjustments which shall be required. Under this warranty, BME Fire Trucks, LLC. shall be responsible for the costs of repairs to the apparatus that have been caused by defective workmanship or materials during this period.

This wananty shall not apply to the following:
. Any component parts or trade accessories such as chassis, engines, tires, pumps, valves, signaling devices, batteries, electric lights, bulbs, alternators, and all other installed equipment and accessories, in as much as they are usually warranted separately by their respective manufacturers, or are subject to 1 0030-0002

Page 4 of 72 ends

10t10t22

Page 81 ends

10/25/2022 Item No.12.
a
a
a
a
Golden State Fire APParatus
normal wear and tear.

Failures resulting from the apparatus being operated in a manner or for a purpose not recommended by the apparatus manufacturer.

Loss of time or use of the apparatus, inconvenience or other incidental expenses.

Any apparatus which has been repaired or altered without written consent or outside of the apparatus manufacturer's factory and or authorized service center in any way that affects its stability, or which has been subject to misuse, negligence, or accident.

Delivery of the apparatus to repair site.

DISCLAIMER
NO WARRANTIES ARE GIVEN BEYOND THOSE DESCRIBED HEREIN. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. THE COMPANY SPECIFICALLY

DISCLAIMS WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,

ALL OTHER REPRESENTATIONS TO THE USER/PURCHASER AND ALL OTHER OBLIGATIONS OR LIABILITIES. FURTHER, THE COMPANY EXCLUDES LIABILITY FOR CONSEQUENTIAL AND INCIDENTAL DAMAGES, ON THE PART OF THE COMPANY OR SELLER. NO PETSON iS AUthOTiZCd tO give any other warranties or to assume any liabilities on the Company's behalf unless made or assumed in writing by the seller; and no other person is authorized to give any warranties or to assume any liabilities on the seller's behalf unless made or assumed in writing by the seller'

OBTAINING SERVICE
Return the vehicle to any BME Fire Trucks, LLC. dealerlauthorized service center; Return the vehicle to BME Fire Trucks ,LLC. or contact BME Fire Trucks, LLC.. BME Fire Trucks, LLC. shall be solely responsible for determining the extent of repair under the terms of the warranty. Transpoftation costs shall be the responsibility ofthe purchaser.

MATERIAL AND WORKMANSHIP
All equipment provided shall be guaranteed to be new and of current manufacture, and unless specified otherwise, shall meet all requirements of these specifications and prevailing NFPA documents and be in condition at time of delivery for use as specified for this type of apparatus.

All workmanship shall be of the highest quality and accomplished in a professionalmanner so as to insure a functional apparatus with a high quality aesthetic appearance. 1 0030-0002

Page 5 of 72 ends

10t10t22

Page 82 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The construction shall be rugged and ample safety factors shall be provided to catry the loads specified to meet both on and off road requirements.

The apparatus shall be designed and the equipment mounted with due consideration to the distribution of load between the front and rear axles, so all specified equipment, with a full complement of personnel, can be carried without damage to the apparatus.

BODY AND STRU WARRANTY
BME Fire Trucks, LLC. shall warrant each new apparatus body, if used in a normal and reasonable manner, against structural defects caused by defects in material, design or workmanship for a period of ten (10) years, covering parts & labor to the original purchaser which shall start on day of acceptance.

This warranty shall not apply to
Normal maintenance selices or adjustments
a
a
a
To any vehicle which will have been repaired or altered outside of our factory in any way so as, in the judgment of BME Fire Trucks, LLC., to affect it's stability, nor which has been subject to misuse, negligence, or accident, nor to any vehicle made by us which will have been operated to a speed exceeding the factory rated speed, or loaded beyond the factory rated load capacity.

Commercial chassis and associated equipment fumished with chassis, signaling devices, generators, batteries, or other trade accessories as they are usually warranted separately by their respective manufacturers.
. Shipping costs of parts or apparatus for purposes of repair or replacement of parts. This warranty is in lieu of all other warranties, expressed or implied. All other representations as to the original purchaser and all other obligations or liabilities, including for incidental or consequential damage on the company's behalf unless made in writing by the company.

DARLEY FIRE PUMP WARRANTY
A three (3)year warranty on the Darley fire pump shall be provided. The provisions of this warranty shall be described in the completed apparatus documentation'

PLUMBING WARRANTY
The stainless steel fire pump plumbing shall carry a ten (10) year parts and labor wananty against defects in workmanship and perforation corrosion.

AKRON VALVE WARRANTY
The Akron valves shall carry a ten (10) year parts and labor manufacturer's warranty. Provisions of this warranty shall be provided with the completed apparatus documentation.

WATER TANK WARRANTY
1 0030-0002

Page 6 of 72 ends

10t10122

Page 83 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
The polypropylene water tank that is specified to be supplied with this apparatus shall be warranted by the water tank manufacturer for a "lifetime" period from the date that the apparatus is put into service. The tank manufacturer shall repair, at no cost to the purchaser, any problems caused by defective materials and/or workmanship. The warranty shall cover the reasonable costs of removing the water tank from the apparatus and reinstalling it after the completion of the covered warranty repairs, but shall not cover any liability for the loss of service or downtime costs of the apparatus.

F'OAM TANKWARRANTY
The foam tank shall carry a"lifetime" warranty against defects in workmanship and perforation corrosion. The provisions of this wananty shall be provided in the delivery documentation. The tank manufacturer shall tepait, at no cost to the purchasei, any problems caused by defective materials andlor workmanship. The warranty shall cover the reasonable costs of iemoving the water tank from the apparatus and reinstalling it after the completion of the covered warranty repairs, but shall not cover any liability for the loss of service or downtime costs of the apparatus.

PAINT WARRANTY
BME Fire Trucks, LLC. shall provide a seven (7)year paint wamanty which shall cover peeling andlot de-lamination of the top coat and other layers of paint, cracking or checking, loss of gloss caused by cracking' checking or chalking, and any paint failure caused by defective paint materials covered by the paint manufacturer' s material warranty.

CHASSIS WARRANTY
The specified chassis shall be provided with the chassis manufacturer's warranfr. The exact provisions of this warranty shall be supplied with the completed apparatus documentation.

APPARATUS OPERATION MANUAL(S)
BME Fire Trucks, LLC. shall provide (2) electronic apparatus operational manual(s) on a USB thumb drive'

APPARATUS OPERATION MANUAL(S)
BME Fire Trucks, LLC. shall provide (2) printed apparatus operational manual(s).

APPARATUS DIMENSIONS
Wheelbase: 183 inches
Cab to center of rear axle:64.10 inches
Overall length: 323 inches (with rear fold up step stowed) Overall main body and cab height: Not to exceed I 18 inches (unloaded).

Hose bed height, floor to ground: Not to exceed 92 inches (Fully Loaded) Crosslay height, floor to ground: Not to exceed 78 inches (Fully loaded) Minimum pump module/running board/under cab compartment ground clearance to be 20 inches Angle of approach: 30' (Fully loaded)
1 0030-0002
PageT of72
10t10122

Page 84 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
Angle of departure: 20o (Fully loaded)

CHASSIS SPECIFICATIONS
Base Chassis, Model HV507 SFA with 183.00 Wheelbase, 64.10 CA, and 65.00 Axle to Frame.

TOW HOOK, FRONT (2) Frame Mounted
AXLE CONFIGURATION {Navistar} 4x4
FRAME RAILS Heat Treated Alloy Steel (120,000 PSI Yield); 10.125" x 3.580" x 0.312" (257.2mm x 90.9mm x 8.0mm);480.0" (12192) Maximum OAL
FRAME REINFORCEMENT Full Outer C-Channel, Heat Treated Alloy Steel (120,000 PSI Yield), 10.813" x

3.892" x 0.312" (274.6mmx 98.8mm x 7.9mm), 480.0" (l2l92mm) OAL BUMPER, FRONT Swept Back l5-Degrees, Steel, for use with Front Frame Extensions, Heavy Duty FRAME, SPECIAL EFFECTS Dimple on Left and Right Top Flange of Frame Rail to Reference Rear Axle Centerline
FRAME EXTENSION, FRONT Integral; 20" \n Front of Grille WHEELBASE RANGE 181" (460cm) Through and Including2}S" (520cm) AXLE, FRONT DRTVING {Meritor MX-12-120 EVO} Single Reduction, 12,000-lb Capacity, with Hub Piloted Wheel Mounting
AXLE, FRONT DRIVING, LUBE {EmGard FE-75W-90} Synthetic Oil; I thru 29.99 Pints SUSPENSION, FRONT, SPRING Parabolic Taper Leaf, Shackle Type, 12,000-lb Capacity, with Shock Absorbers
BRAKE SYSTEM, AIR Dual System for Straight Truck Applications BRAKE LINES Color and Size Coded Nylon
DRAIN VALVE Twist-Type
GAUGE, AIR PRESSURE (2) Air I and Air 2 Gauges; Located in lnstrument Cluster PARKING BRAKE CONTROL YCIIOW KNOb, LOCAICd ON INSITMENt PANCI 1 0030-0002

Page 8 of 72 ends

10t10t22

Page 85 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
PARKING BRAKE VALVE FOT TruCK
eUICK RELEASE VALVE On Rear Axle for Spring Brake Release: 1 for 4x2,2 fot 6x4 SpRING BRAKE MODULATOR VALVE R-7 for 4x2, SR-7 with relay valve for 6x4l8x6 AIR BRAKE ABS {Bendix Antilock Brake System} 4-Channel (4 Sensor/4 Modulator) Full Vehicle Wheel Control System
AIR DRYER {Bendix AD-IP} with Heater
BRAKE CHAMBERS, POSITION Rotated Forward and Up For Maximum Ground Clearance with 4x4 BRAKE CHAMBERS, FRONT AXLE {MGM} 20 SqIn
BRAKE CHAMBERS, REAR AXLE {Bendix EverSure} 30136 SqIn Spring Brake SLACK ADJUSTERS, FRONT {Haldex} Automatic
SLACK ADJUSTERS, REAR {Gunite} Automatic
AIR COMPRESSOR {Cummins} 18.7 CFM
AIR DRYER LOCATION Mounted Inside Left Rail, Behind Transfer Case Mounting AIR TANK LOCATION (2) Mounted Under Battery Box, Outside Left Rail, Back of Cab, Perpendicular to Rail DUST SHIELDS, FRONT BRAKE for Air Cam Brakes
DRAIN VALVE (3) Petcocks, for Air Tanks
DUST SHIELDS, REAR BRAKE for Air Cam Brakes
BRAKES, REAR {Meritor 16.5X7 P} Air S-Cam Type, Cast Spider, Cast Shoe, Double Anchor Pin, Includes Greaseable and Zinc Coated Anchor Pins, Size 16.5" X 7", 38,000-lb Capacity per Axle BRAKES, FRONT {Meritor 16.5X5 Q-PLUS CAST} Air S-Cam Type, Cast Spider, Fabricated Shoe, Double Anchor Pin, Size 16.5" X 5",14,700-lb Capacity
STEERING COLUMN Tilting
STEERING WHEEL 4-Spoke; 18" Dia., Black
1 0030-0002
Page I of 72
10t10122

Page 86 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
STEERING GEAR {Sheppard M100} Power
DRIVELINE SYSTEM {Dana Spicer} SPL170 Main Driveline, 1710 Driveline to Transfer Case, SPL140 Driveline to Front Axle, for 4x4
AFTERTREATMENT COVER Polished Aluminum
EXHAUST SYSTEM Horizontal Aftertreatment System, Frame Mounted Right Side Under Cab, for Single Short Horizontal Tail Pipe, Frame Mounted Right Side Back of Cab, for All-Wheel Drive ENGINE COMPRESSION BRAKE {Jacobs} for Cummins ISL/L9 Engines;with Selector Switch and On/Off Switch
SWITCH, FOR EXHAUST 3 Position, Momentary Lighted Momentary, ON/CANCEL, Center Stable, INHIBIT REGEN, Mounted in IP Inhibits Diesel Particulate Filter Regeneration When Switch is Moved to ON While Engine is Running, Resets When Ignition is Tumed OFF ELECTRICAL SYSTEM l2-Volt, Standard Equipment
DATA LINK CONNECTOR For Vehicle Programming and Diagnostics In Cab HAZARD SWITCH Push On/Push Off, Located on Instrument Panel to Right of Steering Wheel HEADLIGHT DIMMER SWITCH fntegral with Turn Signal Lever PARKING LIGHT Integral with Front Turn Signaland Rear Tail Light STARTER SWITCH Electric, Key Operated
STOP, TURN, TAIL & Bru LIGHTS Dual, Rear, Combination with Reflector TURN SIGNAL SWITCH Self-Cancelling for Trucks, Manual Cancelling for Tractors, with Lane Change Feature
WINDSHIELD WIPER SWITCH 2-Speed with Wash and Intermittent Feature (5 Pre-Set Delays),Integral with Turn Signal Lever
WINDSHIELD WIPERS Single Motor, Electric, CowlMounted
WIRING, CHASSIS Color Coded and ContinuouslyNumbered
1 0030-0002

Page 10 of 72 ends

10t10t22

Page 87 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
CIGAR LIGHTER Includes Ash CuP
HORN, ELECTRIC (2) Disc Style
FOG LIGHTS Prewire; Includes Auxiliary Switch and Wiring to Front Bumper, for Driving Lights or Fog Lights Mounted by Customer
POWER SOURCE Cigar Type Receptacle without Plug and Cord ALTERNATOR {Leece-Neville BLP4006HN} Brushless,l2Yolt,325 Amp Capacity, Pad Mount, with Remote Sense
BODY BUILDER WIRING Rear of Frame; Includes Sealed Connectors for Tail/Amber Tum/\4atketlBackup/ Accessory Power/Ground and Sealed Connector for Stop/Turn BATTERY SYSTEM {Fleetrite} Maintenance-Free, (3) l2-Volt 2850CCA Total, Top Threaded Stud SPEAKERS (2) 6.5" Dual Cone Mounted in Both Doors, (2) 5.25" Dual Cone Mounted in Both B-Pillars ANTENNA for Increased Roof Clearance Applications
RADIO AM/FM/WB/Clock/BluetoothAJSB Input/Auxiliary Input BATTERY CABLES with 36" of Extra Length Coiled and Strapped Near Battery Box DATA RECORDER Includes Display Mounted in Overhead Console STOP-LIGHT WIRING MODIFIED Stop-Lights Turned on When Engine Compression Brake, Exhaust Brake or Retarder is Activated
WINDSHIELD WIPER SPD CONTROL Force Wipers to Slowest Intermittent Speed When Park Brake Set and Wipers Left on for a Predetermined Time
HORN, AIR Accommodation Package, Less Horn
BATTERY BOX Steel, with Fiberglass Cover, 2-4Battery Capacity, Mounted Left Side Perpendicular to Frame Rail, 53" Back of Cab
CLEARANCEA4ARKER LIGHTS (5) {Truck Lite} Amber LED Lights, Flush Mounted on Cab or Sunshade TEST EXTERIOR LIGHTS Pre-Trip Inspection will Cycle all Exterior Lamps Except Back-up Lights 1 0030-0002

Page 11 ends

10t10t22

Page 88 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
HEADLIGHTS ON WWIPERS Headlights will Automatically Turn on if windshield wipers are turned on STARTING MOTOR {Delco Remy 38MT Type 300} 12 Volt, Less Thermal Over-Crank Protection COURTESY LIGHT (4) Mounted In Front & Rear Map Pocket Left and Right Side INDICATOR, LOW COOLANT LEVEL with Audible Alarm
ALARM, pARKING BRAKE Electric Horn Sounds in Repetitive Manner When Vehicle Park Brake is "NOT" Set, with Ignition 'tOFFrt and any Door Opened
INDICATOR, BATTERY WARNING GrEEN BATTERY ON INdiCAtOr, MOUNtEd ON LEft SidC Of INStTMCNI Panel, To be Used with Factory lnstalled or Customer Mounted Battery Disconnect Switch CIRCUIT BREAKERS Manual-Reset (Main Panel) SAE Type III with Trip Indicators, Replaces All Fuses SWITCH, AUXILIARy Switch 40 amp Circuit for Customer Use; Includes Wiring Connection at Power Distribution Center (PDC) and Control in Cab
TURN SIGNALS, FRONT Includes LED Side Tum Lights Mounted on Fender BATTERY DISCONNECT SWITCH 300 Amp, Disconnects Charging Circuits, Locks with Padlock, Cab Mounted
HEADLIGHTS Halogen, with Daytime Running Lights
FENDER EXTENSIONS Omit
LOGOS EXTERIOR Model Badges
LOGOS EXTERIOR, ENGINE Badges
INSULATION, LINDER HOOD for Sound Abatement
GRILLE Stationary, Chrome
INSULATION, SPLASH PANELS for Sound Abatement
BUG SCREEN Mounted Behind Grille
FRONT END Tilting, Fiberglass, with Three Piece Construction, for WorkStarAfV 1 0030-0002

Page 12 ends

10t10t22

Page 89 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
GRILLE EMBER SCREEN Mounted to Grille and Cowl Tray to Keep Hot Embers out of Engine and HVAC Air Intake System
PAINT SCHEMATIC, PT-l Single Color, Design 100

PAINT SCHEMATIC ID LETTERS ''WK''
pAINT IDENTITY ,PT-2Single Color, Instruction No. 936. Frame/Running Gear, Less Fuel Tanks NOTE: Battery Box, Air Tanks, Fuel Tanks, steps and Straps NoT Painted PAINT TYPE Base Coat/Clear Coat, 1-2 Tone
COMMUNICATIONS MODULE Telematics Device with Over the Air Programming; Includes Five Year Data Plan and International 360
PROMOTIONAL PACKAGE Government Silver Package
KEYS - ALL ALIKE,ID I-1003 Compatible with 2-001
CLUTCH Omit Item (Clutch & Control)
ANTI-FREEZE Red, Extended Life Coolant; To -40 Degrees Fl -40 Degrees C, Freeze Protection BLOCK HEATER, ENGINE l20V/1000W, for Cummins 158/B6.7llSLlLg Engines BLOCK HEATER SOCKET Receptacle Typ"; Mounted below Drivers Door ENGINE, DIESEL {Cummins L9 350} EPA2021,350HP @2200 RPM, 1050 lb-ft Torque @1200 RPM, 2200 RPM Governed Speed, 350 Peak HP (MaD
FAN DRIVE {Horton Drivemaster} Two-Speed Type, Direct Drive, with Residual Torque Device for Disengaged Fan Speed
FANNylon
RADIATOR Aluminum, Cross Flow, Front to Back System,1228 SqIn, with I167 SqIn Charge Air Cooler, Includes In-Tank Oil Cooler
DEAERATION SYSTEM with Surge Tank
1 0030-0002

Page 13 of 72 ends

10t10t22

Page 90 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
HOSE CLAMPS, RADIATOR HOSES Gates Shrink Band Type; Thermoplastic Coolant Hose Clamps RADIATOR HOSES Premium, Rubber
AIR CLEANER Dual Element
EMISSION, CALENDAR YEAR {Cummins L9} EPA, OBD and GHG Certified for Calendar Year2022 THROTTLE, HAND CONTROL Engine Speed Control; Electronic, Stationary, Variable Speed;Mounted on Steering Wheel
FAN OVERRIDE Manual; with Electric Switch on Instrument Panel, (Fan On with Switch On) ENGINE WATER COOLER {Sen-Dure} Auxiliary, For use with Fire Trucks CARB IDLE COMpLIANCE Engine Shutdown System Exempt Vehicles, Complies with California Clean Air Regulations
CARB EMISSION WARR COMPLIANCE for Cummins L9 Engines
ENGINE CONTROL, REMOTE MOLINTED Provision for; Includes Wiring for Body Builder Installation of PTO Controls and Starter Lockout, with Ignition Switch Control, for Cummins 86.7 and L9 Engines TRANSMISSION, AUTOMATIC {Allison 3000 EVS} 5th Generation Controls, Close Ratio, 6-Speed with Double Overdrive, with PTO Provision, Less Retarder, Includes Oil Level Sensor TRANSFER CASE {Meritor MTC-4210} 2-Speed, 10,000 lb-ft Torque Rating, Less PTO Provision, Electric Over Air Control, with Lube PumP
OIL COOLER, AUTO TRANSMISSION {Modine} Water to Oil Type TRANSFER CASE LUBE {EmGard 50W} Synthetic; I thru 14'99 Pints TRANSMISSION SHIFT CONTROL Column Mounted Stalk Shifter, Not for Use with Allison 1000 & 2000 Series Transmission
OL COOLER, TRANSFER CASE with Oil Coolant Lines Routed to Oil Cooler TRANSMISSION OIL Synthetic;29 thru 42 Pints
ALLISON SPARE INPUT/OUTPUT for Emergency Vehicle Series (EVS), Rescue, Ambulance, Package Number 170
1 0030-0002

Page 14 of 72 ends

10t10122

Page 91 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
SHIFT CONTROL PARAMETERS {Allison} 3000 or 4000 Series Transmissions, Performance Programming PTO LOCATION Dual, Customer Intends to Install PTO at Left and/or Right Side of Transmission AXLE, REAR, SINGLE {Meritor RS-26-185} Single Reduction, 26,000-lb Capacity, R Wheel Ends . Gear Ratio:5.86
SUSPENSION, REAR, SINGLE 31,000-lb Capacity, Vari-Rate Springs, with 4500-lb Capacity Auxiliary Multileaf Springs
sHocK ABSORBERS, REAR (2)
AXLE, REAR, LUBE {EmGard FE-75W-90} Synthetic Oil;40 thru 49.99 Pints DEF TANK 9.5 US Gal (36L) Capacity, Frame Mounted Outside Left Rail, Under Cab FUEL/WATER SEPARATOR {Racor 400 Series} 12 VDC Electric Heater,Includes Pre-Heater, with Primer Pump,Includes Water-in-Fuel Sensor, Mounted on Engine
FUEL TANK Top Draw, Non-Polished Aluminum,26" Dia,70 US Gal (265L), Mounted Left Side, Under Cab AUXILIARY FUEL DRAW TUBE Located at Auxiliary Port on Fuel Tank CAB Conventional6-Man Crew Cab
AIR CONDITIONER with Integral Heater and Defroster
GAUGE CLUSTER Base Level; English with English Electronic Speedometer GAUGE CLUSTER DISPLAY: Base Level (3" Monochromatic Display); Odometer, Voltmeter, Diagnostic Messages, Gear Indicator, Trip Odometer, Total Engine Hours, Trip Hours, MPG, Distance to Empty/Refill GAUGE CLUSTER Speedometer, Tachometer, Engine Coolant Temp, Fuel Gauge, DEF Gauge, Oil Pressure Gauge, Primary and Secondary Air Pressure
WARNING SYSTEM Low Fuel, Low DEF, Low Oil Pressure, High Engine Coolant Temp, Low Battery Voltage (Visual and Audible), Low Air Pressure (Primary and Secondary) SEATBELT WARNING PREWIRE lncludes Seat Belt Switches and Seat Sensors for all Belted Positions in the Cab and a Harness Routed to the Center of the Dash for the Aftermarket Installation of the Data Recorder and Seatbelt Indicator Systems, for 4 to 6 Seat Belts
1 0030-0002

Page 15 of 72 ends

10t10t22

Page 92 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
GAUGE, OIL TEMP, AUTO TRANS for Allison Transmission
GAUGE, AIR CLEANER RESTRICTION {Filter-Minder} with Black Bezel, Mounted in lnstrument Panel Ip CLUSTER DISPLAY On Board Diagnostics Display of Fault Codes in Gauge Cluster GRAB HANDLE, EXTERIOR (2) Chrome, Towel Bar Type, with Anti-Slip Rubber lnserts, for Cab Entry Mounted Left and Right Side at B-Pillar
GRAB HANDLE, ADDITIONAL EXT (2) Chrome, Towel Bar Type, with Anti-slip Rubber Inserts, Mounted Left and Right Side, Rear of Rear Doors, for Crew Cab
SEAT, REAR {National} BENCH;Full Width;Vinyl, with Fixed Back and Two Integral outboard Headrests MIRRORS (2) C-Loop, Power Adjust, Heated, LED Clearance Lights, Bright Heads and Arms, 7.5" x 14" Flat Glass, Includes 7 .5" x 7" Convex Mirrors, for 102" Load Width Mirror Dimensions are Rounded to the Nearest

0.5"
SEAT BELT All Red; 4 to 6
CAB INTERIOR TRIM Classic, for Crew Cab
CONSOLE, OVERHEAD Molded Plastic with Dual Storage Pockets, Retainer Nets and CB Radio Pocket; Located Above Driver and Passenger
DOME LIGHT, CAB Door Activated and Push On-Off at Light Lens, Timed Theater Dimming, lntegral to Overhead Console, Center Mounted
SLrN VISOR (2) padded Vinyl; 2 Moveable (Front-to-Side) Primary Visors, Driver Side with Toll Ticket Strap CAB SOTIND INSULATION Includes Dash Insulator and Engine Cover Insulator WINDOW, POWER ( ) And Power Door Locks, Front and Rear Doors, Left and Right, lncludes Express Down Feature
HOURMETER, PTO for Customer Provided PTO; with Indicator Light and Hourmeter in Gauge Cluster Includes Return Wire for PTO Feedback Switch
CAB REAR SUSPENSION Air Bag TYPe
INSTRUMENT PANEL Flat Panel
1 0030-0002

Page 16 ends

10t10122

Page 93 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
ACCESS, CAB Steel, Driver & Passenger Sides, Two Steps per Door, for use with Crew Cab STEP, STANDARD, OMIT Driver & Passenger Sides, Omit Rear Steps for use with Crew Cab WHEELS, FRONT {Accuride 42644} DISC; 22.5x8.25 Rims, Standard Polish Aluminum, l0-Stud, 285.75mm BC, Hub-Piloted, Flanged Nut, with Steel Hubs
WHEELS, REAR {Accuride 42644} DUAL DISC; 22.5x8.25 Rims, Standard Polish Aluminum, l0-Stud, 285.75mm BC, Hub-Piloted, Flanged Nut, with Steel Hubs
(2) TIRE, FRONT 12R22.5 Load Range H XDN2 (MICHELIN),483 rev/mile, 75 MPH, Drive (4) TIRE, REAR 12R22.5 Load Range H XDN2 (MICHELIN),483 rev/mile, 75 MPH, Drive MISCELLANEOUS SINGLE TONE CAB 1-2 BREAKS 35200---21GWK Color I Red FLNA30012 Colormap 405G4
WARRANTY Standard for HV507, HV50B, fry607 Models, Effective with Vehicles Built July 1, 2017 or Later, CTS-2025A
4yrAJnlimited Mile Extended Warranty Covering A/C

CAB SEATING AND ALLOWANCE
A warning label shall be installed in the cab to indicate seating positions for five (5) people. A weight allowance of250 pounds shall be calculated for each person.

LABELS. STANDARD PACKAGE SET
A standard set of labels shall be provided and installed on the inside of chassis cab area. The labels shall contain the required information based on the applicable components for the apparatus.

DATA ,AOIIE,
A data plaque shall be provided and installed on the inside of the driver's door. The data plaque shall contain the required information based on the applicable components for the apparatus:

Engine oil
Engine coolant
Chassis transmission fluid
Drive axle lubricant
Power steering fluid
Pump, generator, or other component lubrications
Other NFPA applicable fluid levels or data as required
1 0030-0002

Page 17 of 72 ends

10t10122

Page 94 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
Paint manufacturer, type, and color number
Tire Speed Ratings
Location shall be in the driver's compartment or on the driver's door

DIESEL ONLY LABEL
The fuel tank shall be labeled with a "Diesel Only" label that is green in color'

HOT EXHAUST LABEL
A "CAUTION HOT EXHAUST" label will be placed directly over the exhaust outlet on the apparatus body' WARNING LABEL .. NO RIDING ON REAR
A warning label stating: "WARNING: DO NOT RIDE ON REAR STEP WHILE VEHICLE IS IN MOTION.

DEATH OR SERIOUS INJIIRY MAY RESULT" shall be installed on the rear of the apparatus. The label shall be applied to the vehicle at the rear step area. The label shall warn personnel that riding in or on these areas, while the vehicle is in motion, is prohibited.

WARNING LABEL .- SEAT BELT USAGE
A warning label, stating: "WARNING CRASH HAZARD OCCUPANTS MUST BE SEATED AND BELTED WHEN VEHICLE IS IN MOTION..." shall be provided in the apparatus cab interior. This label shall be located so that it is visible from all seating positions.

LOUD NOISE WARNING LABEL
A final stage manufacturer shall install "hearing loss" potential warning labels on the vehicle in any areas or fixed equipment that produces excessive noise levels. (Exhaust outlet, sirens and air horns shall not be required for such equipment.)

AIR FILTER EMBER PROTECTION SCREEN WARNING LABEL
A waming label, stating: "THIS VEHICLE HAS AN AIR INTAKE EMBER SCREEN WHICH REQUIRES PERIODIC INSPECTION & CLEANING" shallbe provided and installed in the apparatus cab interior.

F'RESH AIR MRN,R SE,PARATOR G LABEL
A warning label, stating: "THIS APPARATUS IS EQUIPPED WITH A CAB FRESH AIR INTAKE EMBER pROTECTION SCREEN. ROUTINE INSPECTION IS REQUIRED." shall be provided and installed in the apparatus cab interior.

WAR}IING LABEL .. DO NOT WEAR HELMET
A warning label, stating: "CAUTION: DO NOT WEAR HELMET WHILE SEATED" shall be provided in the apparatus cab interior. This label shall be located so that it is visible from all seating positions.

MANUFACTURER LOGO
The apparatus shall include a BME logo plaque which shall be affixed at the rear of the apparatus. a
a
1 0030-0002

Page 18 of 72 ends

10t10t22

Page 95 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
The BME plaque shall feature white reflective material on the outside of the Maltese cross and red reflective material in the middle.

F'RONT TOW PLATE
A horizontal full frame width, '/o-inchthick steel plate, center pull, front tow eye shall be furnished and installed through or below the front bumper. The tow eye plate shall be triangle shaped extended 6 inches beyond the front bumper with a 3-inch X 4-inch rectangle tow eye.

The tow eye shall be braced and gusseted to prevent frame rail or bumper damage and bolted to the front frame rail web with eight (8) Grade 8 frame bolts and lock nuts.

The tow plate shall to be sprayed with black durabak.

FRONT RECEIVER
There shall be one bolted 2" receiver hitch on the front of the apparatus. The receiver shall be mounted off set as to prevent towing use.

REAR RECEIVER
There shall be one bolted 2" receiver hitch on the rear of the apparatus. The receiver shall be mounted off set as to prevent towing use.

REAR BUSTLE
A single, frame mounted, 3-inch X 4-inch diameter, rear towing eye shall be provided. It shall be manufactured from3/+-inch thick steel plate and bolted between the rear frame rail webs with a minimum of eight (8), four (4) on each side, SAE Grade 8 frame bolts and lock nuts.

The tow eye shall be braced and gusseted to prevent damage to the frame rails, bumper or apparatus body while being towed from various angles. Access to the tow eye shall be below the bumper and designed not to interfere withhe required angle of departure. The bustle shall be painted job color.

FRONT FRAME EXTENSION
The front frame rails shall be extended 16" ahead of the cab grill or fender area.

BUMPER PLATFORM
The front bumper extended frame rails shall feature an overlay constructed of .125 inch, 5052 grade, aluminum deck bright *t i.h shall offer space for mounting components necessary to the apparatus. The bumper extension shall measure approximately sixteen (16) inches from the cab to the front face of the extension and shall be approximately eight (8) inches in height.

DRIVERS SIDE -- FRONT BUMPER COMPARTMENT
1 0030-0002

Page 19 of 72 ends

10110122

Page 96 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
One (1) recessed hose storage compaltment shall be installed in the drivers side of the bumper. The compartment shall be constructed of smooth aluminum. The floor of the compartment shall have drain holes provided.

BUMPER COMPARTMENT NYLON HOLD DOWN STRAP
One (1) nylon strap with a buckle shall be installed on the specified front bumper compartment. The nylon strap shall act as a hold down mechanism for the hose in the compartment.

The straps shall be black in color.

BUMPER COMPARTMENT GRATING
The specified bumper compartment shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color.

CENTER -- FRONT BUMPER COMPARTMENT
One (1) recessed hose storage compartment shall be installed in the center front bumper. The comparlment shall be constructed of smooth aluminum. The floor of the compartment shall have drain holes provided.

BUMPER COMP RTMENT DOOR
An aluminum tread plate door shall be installed on the specified front bumper compartment. The non-skid surface door shall have a stainless steel hinge atthe rear,latch, and hold open device installed' The specified door(s) shall have a Polished stainless-steel D-ring door handle.

BUMPER COMPARTMENT GRATING
The specified bumper compartment shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color.

PASSENGER SIDE -- FRONT BUMPER COMPARTMENT
One (l) recessed hose storage compartment shall be installed in the passenger side of the bumper- The compartment shall be constructed from smooth aluminum. The floor of the compartment shall have drain holes provided.

BUMPER COMPARTMENT NYLON HOLD DOWN STRAP
One (1) nylon strap with a buckle shall be installed on the specified front bumper compartment. The nylon strap shall act as a hold down mechanism for the hose in the compartment.

The straps shall be black in color.

BUMPER COMPARTMENT GRATING
1 0030-0002

Page 20 of 72 ends

10t10122

Page 97 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The specified bumper compartment shall be fitted with removable interlocking vinyl Dri-Dek grating' This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color.

BUMPER
There shall be an International 15 degree bumper installed on the apparatus

FRONT COI,OR
The front bumper shall be painted job color

BUMPER SIDE WINGS
The bumper shall have steel side wings.

FRONT BUMPER WINGS COLOR
The front bumper wings shall be painted job color

AIR HORN
One (1) Buell brand, Model #1063 15" air horn shall be provided and mounted on the frame rail of the passenger's side frame, behind the bumper.

AIR HORI\ FOOT SWITCH
One (l) foot switch shall be provided and installed. The foot switch shall be located on the driver's side of the floor and shall activate the air horn system.

B:.XHAUST SYS MODIIIICATION
The chassis exhaust system shall be modified to exit on the passenger side of the apparatus ahead of the rear wheel. The exhaust pipe modification shall be made from Stainless Steel and shall have an exhaust hanger every 12 inches.

EXHAUST HEAT WRAP
The exhaust pipe shall be wrapped with heat wrap from the diesel particulate filter to just shy of the end of the tailpipe.

BUMPER BOX PROTECTIVE FLAP
The protective flap shall be a cut down mud flap installed on the rear edge of the front bumper to eliminate debris from being deposited on the top of the front bumper and in the hose boxes.

REAR MUD FLAPS
The chassis shall be supplied with mud flaps with BME's logo. The mud flaps shall be installed behind the rear wheels.
1 0030-0002
Page21 of72
10t10122

Page 98 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus

DRIVER SIDE CAB STEP
The apparatus shall be equipped with a chassis fuel tank and step area. The fuel tank and step area shall be located on the drivers side of the commercial chassis. The fuel tank shall be covered with aluminum tread plate.

DRIVER'S SIDE UNDER CAB COMPARTMENT
The apparatus shall be equipped with an enclosed stainless steel compartment located under the crew door on the left side of the cab. The compartment shall measure approximately 36" wide x 18" high x 21" deep with a hinged aluminum door and a D-ring style latch'
The doors shall be painted job color

BRASS BOX SLIDE TRAY
The left under cab compartment shall have these additional items installed, a 10-gauge reinforced plain anodized aluminum sliding drawer-type tray with a 4-inchvertical flange on all sides to be utilized for the storage ofnozzles and adapters.

The tray shall utilize the maximum available space within this compartment and have extra heavy duty 500 pound lock-in/lock-out roller glides with stops to prevent it from sliding all the way out and to hold it securely in place when the compartment door is opened or closed' The brass box tray shall feature adjustable l6 section slotted 4-inch high "egg-crate" divider designed for vertical storage ofvarious nozzles and adapters'

COMPARTMENT LIGHTING
One (1) Code 3 800 Series Corner LED lights shall be installed in the specified compartment(s).

COMPARTMENT LIGHT / DOOR SWITCH
The interior compartment light shall be automatically controlled by a door activated "On-Off' switch. The switch shall be tied to the door ajar system also.

PASSENGER'S SIDF],IINDER CAB ARTMF],NT
The passenger side under cab compartment shall be mounted below the rear cab doors in front of the relocated battery box, the compartment shall be made from stainless steel and have provisions to mount the upper and lower steps to it. The box and door shall be painted job color and shall have an aluminum diamond plate over lay that covers the top and both sides.

COMPARTMENT LIGHTING
One (1) Code 3 800 Series Corner LED lights shall be installed in the specified compartment(s).

COMPARTMENT LIGHT / DOOR SWITCII
1 0030-0002
Page22 of 72
10t10t22

Page 99 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The interior compaftment light shall be automatically controlled by a door activated "On-Off' switch. The switch shall be tied to the door ajar system also.

CAB STEPS
Aggressive, extruded aluminum surfaces shall be installed on each of the cab steps areas. The outside edges of the specified step shall be provided with 2" x l.5" x .250" extruded and knurled aluminum rub rails.

CAB DOOR REFLECTIVE PANELS
The cab doors shall include reflective trim installed inside each door Specified part shall include White reflective striping.

REAR AIR RIDE SEATS

CAB SEATING
The apparatus shall be equipped with two (2) Bostrom Sierra 100 air ride seats. The seats shall have an inside (l) arm rest.

The specified seat(s) covers shall be dark grey vinyl.

FRONT AIR RIDE SEATS

CAB SEATING
The apparatus shall be equipped with two (2) Bostrom Sierra 100 air ride seats. The seats shall have an inside (l) arm rest.

The specified seat(s) covers shall be dark grey vinyl.

REAR WALL ALUMINUM PLATE . F'ULL HEIGHT
Behind the rear seat mounted vertically on the inside rear wall of the cab a ll4 inch aluminum sheet that is approximately 50 inches high by 60 inches wide will be mounted in the center resting on the floor to the rear wall of the cab inside with eight (8) % inch bolts with nutserts on the double wall supports.

This piece of aluminum will be centered, and the mounting bolts will not go through the outside of the cab. This piece of aluminum will be for hanging AVL electrical components after delivery.

This aluminum piece will completely cover the rear window for safety.

There will be a sticker in the middle of the aluminum cover for the rear window that will state do not drill in red one inch letters.

FAN CLUTCH LOCK UP
The fan clutch shall lock up when the apparatus is shifted into pump mode.

AIR HOSE OUTLET
(l) female quick connect air inlet/outlet shall be provided and installed and labeled "AIR INLET-OUTLET".

The quick connect fitting shall provide connection to a utility air hose and shall be located on the pump 1 0030-0002

Page 23 of 72 ends

10t10t22

Page 100 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
operator,s panel. A round shutoff valve shall be supplied next to the air inlet/outlet and labeled "AIR SHUT.OFF''

AIR TANK RELOCATION
The air tanks shall be relocated to the rear of the truck between the frame rails.

REMOTE MOUNT FRONT AXLE BREATHER HOSE
The front axle shall have a remount mount breather with hose, and have a metal 1/4" (LDI Industries 1U573 or equivalent) style vent will be supplied and gain two of lift and be mounted to the firewall on passenger side.

BATTERY RELOCATION
The chassis batteries are to be relocated to the passenger side of the chassis, below the rear cab door in the o.E.M. battery box, aft of the under cab compartment. The box shall have an aluminum diamond plate lid, and have provisions to mount an upper cab step to it.

UNDERIIOOD LIGHTS
There shall be two (2) Tecniq LED light(s) installed under the hood of the chassis. Lights shall have local switching on the driver side under the hood.

LED HEADLIGHTS REPLACEMENT
The factory halogen headlights shall be replaced with LED headlights. The headlights shall be Truck Lite #27270C7" LED.

AUXILIARY AIR CONDITIONER
The cab shall have a Red Dot #R6840 auxiliary air conditioner installed at the back wall of the cab. The auxiliary unit shall be connected to the OEM A/C compressor and feature it own fan speed and temperature controls. The unit shall be capable of 22,300 BTU/FIr cooling capacity with a 325 CFM fan'

AIR FILTER EMBER PROTECTION SCREEN AND WARNING LABEL
The chassis air intake shall be protected by an ember guard of 18 Mesh,0.017-inch wire diameter, and a maximum mesh opening of 0.0j9 inches. The ember guard shall be sized to fit and located at the intake opening. The screen shall be readily accessible for inspection and maintenance. The ember guard shall maintain a minimum lrinch separation from the air filter.

EMBER SEPARATOR.. F'RESH AIR INTAKE TO CAB
The cabin air filter shall be protected by an ember guard with a maximum mesh opening of 0'039 inches.

EMBER SEPARATOR
The final stage manufacturer shall install a stainless steel ember separator within the fire pump engine air intake system.

FUEL TANK SKID PLATE
'10030-0002

Page 24 of 72 ends

10t10122

Page 101 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
A heavy duty removable skid plate shall be fastened to the bottom side of the fuel tank. The skid plate shall have the front and rear sides turned up to prevent digging into the ground when the apparatus is in off road conditions.

EXTERIOR CAB TRIM
A rubber debris skirt will be installed to prevent debris and embers from entering between the cab and frame.

The debris skim will be attached with a 12 gauge stainless steel trim piece the full length along the lower cab seam below the cab doors. The trim shall be fastened to the body seam with evenly spaced l0/32 stainless steel Phillips head machine screws and nylock nuts.

AIR. F'UEL. ELECTRICAL LINE PROTECTION
All air lines, fuel lines and electrical harnesses below the chassis frame rails shall be protected with fire resistive sleeves.

FUEL TANK VENTING
The O.E.M fuel tank vent line shall be extended from the fuel tank and vented to the atmosphere. The vent line shall extend vertically from the tank to the bottom of the cab rear window and then bend 180 degrees towards the ground. A vent plug orifice (#60 drill size) shall be installed into the upper end of each line. No fueltank roll over protection check valves shall be removed from the fuel system. Any chassis fuel system modifications shall be fully compliant CARB regulations, CVC and FMVSS'
All fuel vent lines shall be copper, steel, or Aeroquip hose, and shall be loomed, "grommeted", and firmly clamped in position to prevent chafing or damage and all synflex fuel hoses shall be wrapped with fire wrap lagging capable of withstanding temperatures in excess of 250"C.

The fuel tanks and lines shall be protected as necessary from exhaust heat through the use of heat shields or baffles. Use only metal fasteners, coated or insulated for maximum fuel line protection.

ECM PROGRAMMING
The cab and chassis ECM shall be programmed as required to allow the apparatus to acheive 68 MPH top speed.

Performance Taq - Portable PumP
A tag shall be provided on the pump control panel indicating the performance of the portable pump Pump Performance
20 gpm @ 310 psi
140gpm @l45psi
180 gpm @ 80 psi

FIRE PUMP SPECIFICATIONS
A Darley model JMP 500 GPM two stage fire pump shall be installed. Power to drive the pump shall be provided by the same engine used to propel the apparatus. The pump shall be equipped with a series-parallel 1 0030-0002

Page 25 ends

10t10122

Page 102 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
changeover valve control on the pump panel'
pump casing shall be a fine grain cast iron, with a minimum tensile strength of 30,000 PSI' Pump shall contain a cored heating jacket feature that, if selected, can be connected into the vehicle antifteeze system to protect the pump from freezing in cold climates, and to help reject engine heat from engine coolant, providing longer life for the engine. Seal rings shall be renewable, double labyrinth, wrap around bronze type' The pump shaft shall be splined to receive broached impeller hubs, for greater resistance to wear, torsional vibration, and torque imposid by engine, as well as ease of maintenance and repair' Bearings provided shall be heavy duty, deep groove, radial-type ball bearings. Sleeve bearings on any portion of the pump or transmission shall be prohibited due to wear, deflection, and alignment concems. The bearings shalibe protected at all openings from road dirt and water splash with oil seals and water slingers' The impeller shall be a high strength bronze alloy, splined to the pump shaft for precision fit, durability, and ease of maintenance. Impel-ler shaft oil seals shall be constructed to be free from steel components except for the internal lip spring. The impeller shaft oil seals shall carry a lifetime warranty against damage from corrosion from water and other fire-fighting fluids.

The pump transmission case shall be heavy-duty cast iron with adequate oil reserve capacity to maintain low operating temperature. pump ratio to be seiected by the manufacturers engineering department. Gears shall be helical in design and precisi,on ground for quiet operation and extended life. Gears to be cut from high strength alloy steel, giound, and carburized. Chain drive andlor design requiring extra lubricating pump is not acceptable.
pump drive shaft shall be precision ground, heat-treated alloy steel, with a 1-318 spline. Gears shall be helical design, and shall be precision g.ounJfo, quiet operation and extended life. The pump transmission shall require no further lubrication beyond that providei uv ttr. intrinsic action of the gears, to reduce the likelihood of failure due to loss of auxiliary lubrication.

MECHANICAL SEAL
The mechanical seal shall use silicon carbide mechanical seals with welded springs. The stationary face of our mechanical seals shall be made from silicon carbide, an extremely hard and heat dissipative material' which resists wear and dry running damage'

PUMP SHIFT NO PUMP AND ROLL
The pump transmission shall be engaged by a guarded toggle switch which will lock in both the road and the pump *od" to ensure that accidental pump engagement or disengagement is avoided' The main fire pump shift controls shall be mounted in the cab and identified as "PUMP SHIFT" and shall include a perrnanently inscribed pump shift instruction I.D. plate. The pump shift controls shall include 1 0030-0002
Page26 of 72
10110122

Page 103 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
indicating lights located on the in-cab and left pump panels that advise the operator that the pump shift has been completed and it is O.K. to pump.

The indicating lights shall be as follows:
o To indicate that the pump shift has been successfully completed. o An "O.K. to Pump" light located in the cab to indicate that the pump is engaged, the transmission is in neutral and the A "Pump Engaged" light located in the cab and on the left pump panel parking brake is set.
o A "Throttle Ready" light located on the left pump operators' panel to indicate the apparatus is in the O.K. to Pump mode.

The main pump shall be used for stationary pumping only. The main pump shall include a lock-out system that is interfaced with the apparatus electrical and parking brake systems and is designed to keep the main pump from being used in pump and roll operations.

The transfer valve will cycle every time the ignition is turned on to keep calcium buildup down and maintain movement of the valve. Once it cycles it will return to the switch location. The switch will default to *pressure* mode.

FIRE PUMP ANODE SYSTEM
The fire pump plumbing system shall be provided with anode system to reduce corrosion within the piping. The anode shall be bolt-in or screw-in type and easily replaceable.

ELECTRIC PRIMER SPECIFICATIONS
A 12 volt electrically driven positive displacement fire pump primer system shall be installed. The priming pump shall be constructed of heat treated aluminum and hard coat anodized and shall not use oil in the operation. The system shall perform in compliance to applicable NFPA standards.

FIRE PUMP TEST
The fire pump shall undergo factory fire pump tests for a minimum of 30 minutes of continuous pump at rated capacity at rated net pump pressure prior to delivery of the completed apparatus. the complete pump test shall include a pressure control test, a priming system test, a vacuum test and a water tank to pump flow test. The factory pump testing results shall be furnished on delivery.

FIRE PUMP PTO AND DRIVELINES
A "Hot Shift" power-take-off shall be installed on the transmission PTO opening with the controls located in the chassis cab, with an AMBER waming light to note engagement. The drive shaft and universals shall be sized for intended usage and pump rating.

INTAKE DUMP VALVE
1 0030-0002
Page27 of72
10t10t22

Page 104 ends

10/25/2022 Item No.12.

Golden State Fire ApParatus
An Elkhart model #40140 intake dump valve shall be provided and plumbed into the intake side of the main pump. The valve shall be preset from the factory at 125 psi. The pressure setting controls for the valve shall be accessible from beneath the pump compartment.

The 45" stainless steel discharge pipe shall be angled away from the tire and teminate with a 2%-inch NST male adapter and labeled "Do Not Cap"'

THERMAL PUMP COOLER
The fire pump shall be equipped with an overheat protection device which monitors the temperature of the water inside the pump and relieves water when the temperature inside the pump exceeds 140 degrees Fahrenheit. The Waterous Model #OpM shall also have an warning light on the pump panel to provide additional protection in the event the temperature inside the pump continues to rise with the overheat protection valve open. The warning light and test button shall be mounted to a heavy polished casting that is mounted to the pump operator's panel.

MASTER PUMP DRAIN
One (l) Trident, multiple-port drain valve, fabricated from bronze, shall be provided and controlled at the pump operator's control pun.t. The valve shall be opened by tuming a rotary hand wheel. The valve shall be plumbed to drain both the discharge and intake sides of the pump, the relief valve and other plumbing components as required.

The valve shallbe placed as low as possible to provide proper drainage of the components plumbed to it. The valve shall be rated to 600 PSI minimum and suitable for daily valve actuation.

MAIN PUMP PLUMBING
The pTO main pump plumbing system shall utilize stainless steel piping incorporating hosing to allow for flex.

The piping shali utilize TIG welding to provide a complete seal. Hard angles shall be avoided when possible to improve water flow characteristics. The piping shall utilize Victaulic couplers whenever possible to allow flex as the body module flexes.

Threaded sections of piping shall be avoided to reduce the leak potential of the system. Victaulic couplers shall be used in place of threading to reduce leak potential. Schedule 10 stainless steel piping shall be used for transport type piping. Schedule 40 stainless steel shall be used for areas requiring threading to provide a stable threading base. Brackets shall be installed to support threading locations thereby reducing the potential for leaks All hoses shall be connected directly to the tank due to the different flex ratios of the tank to body' Any front discharges, any rear discharges, and all cross lays shall use hose to reach the actual discharge. The use ofhose shall be utilized due to the difference in flex or movement between the discharge location and the pump connection. Drain lines shall be provided at the lowest points in the plumbing system to allow for complete drainage. Bleeders shall be provided for all gauges to relieve pressure after use.

PORTABLE PUMP
1 0030-0002

Page 28 of 72 ends

10t10122

Page 105 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
A Darley l-llzAGE 24K portable pump shall be provided on the apparatus. The unit shall have a liquid cooled, 24IJF, Kubota D902 diesel engine equipped with an electric start.

Pump Performance
20 gpm @ 310 psi
140gpm @l45psi
180 gpm @ 80 psi
Diesel Eneine
Kubota, D902 Diesel, water-cooled,24 hp
Fuel Supply
The engine shall be piped to the chassis fuel system with provisions to prevent fuel drain back to the tank when the engine is shutdown.

Fuel Prime
A fuel re-prime pump shall be provided to assist in fuel delivery to the diesel engine from the chassis tank.

Lubrication
Pressure feed with spin-on filter
Starter
12-volt electric wired into the chassis battery system
Exhaust
A spark arrestor shall be provided on the engine exhaust system Air Intake
An air cleaner shall be provided with easy access to remove the element.

An ember screen shall be provided on the inlet to the air cleaner.

The auxiliary fire pump shall provide pressure to all 2-inch discharge valves only including the hose reel and be capable of re-circulating tank water for pump cooling purposes through the 2-inch tank filler valve. *NOTE* .The engine oil dipstick will be at the same level of height as the valve cover on the auxiliary engine.

CATTRON CONTROL PANELS
The auxiliary pump throffle controls shall be Cable Craft, low friction, lockable style throttle cables. There shall be one (1) throttle cable mounted on the cab console and one (l) throttle cable mounted on the left side operators pump panel.
1 0030-0002

Page 29 of 72 ends

10t10t22

Page 106 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
Panel to include the following items:

Start / Stop Push Button Switch
Ignition "On" Light (Green)
Low Engine Oil Pressure Light
High Engine Temperature Light
Low Pump Water Pressure Light
Alternator Charge Fail Light
Glow Plug Active Light
Push Button Primer
Tachometer
Discharge Pressure Gauge (Red Back Lighted)
Vernier Throttle

AUX BYPASS I,E,R
An auxiliary pump shall have cooling ability. A line will be installed for the auxiliary pump output that uses 1/8 inside diameter hose 300 psi minimu* uni will travel to the tank fill tower and drain inside facing down and have a check valve installed for priming purposes.

This line will always flow water when the auxiliary pump is running and drain back into the tank. If larger than l/g inside diameter hose is used an orifice tube to reduce the flow to 1/8 inch will be installed.

AUXILIARY PUMP PLUMBING
The auxiliary fire pump plumbing system shall utilize stainless steel piping incorporating hosing to allow for flex. The piping shal utilize TIG welding to provide a complete seal. Hard angles shall be avoided when possible to improve water flow characteristici. The piping shall utilize victaulic couplers whenever possible to allow flex as the body module flexes'
Threaded sections of piping shall be avoided to reduce the leak potential of the system. Victaulic couplers shall be used in place of thi"uaing to reduce leak potential. Schedule 10 stainless steel piping shall be used for transport type piping. Schedule 40 stainless steel shall be used for areas requiring threading to provide a stable threading base. Brackets shall be installed to support threading locations thereby reducing the potential for leaks.

All hoses shall be connected directly to the tank due to the different flex ratios of the tank to body. Any front discharges, any reardischarges, and all cross lays shall use hose to reach the actual discharge. The use ofhose shall be utilized due to the difference in flex or movement between the discharge location and the pump connection.

AUXILIARY PUMP EXHAUST SYSTEM
The auxiliary fire pump and engine assembly shall have a muffler and exhaust pipe. The exhaust pipe shall be directed out of the compartmeniand away from the pump operator. An additional guard shall be installed where the pipe is exposed to touch by an operator.
1 0030-0002

Page 30 of 72 ends

10110122

Page 107 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
LOW PRESSURE PUMP SHUT.DOWN
If the fire pump runs out of water and the pressure decreases below 20 PSI, an automatic pressure switch shall detect the condition, and turn off the fire pump operation.

LOW OIL PRESSURE / IIIGH TEMPERATURE PUMP SHUT-DOWN
If the fire pump has low oil pressure or high engine temperature, automatic pressure switches shall detect the condition, and the device shail turn off the fire pump operation. There shall be an override switch provided and installed on the operators pump panel to allow the system to be disabled when required.

AUXILIARY FUEL SYSTEM
The fuel system for the auxiliary fire pump shall be plumbed to the chassis fuel system. There shall be a separate fuel pickup tube mounted in the chassis fuel tank specifically for a separate engine driven pump assembly' There shall be an electric fuel pump with regulator and fuel hose furnished between the chassis fuel tank and the auxiliary pump.

The fuel tank pick-up tube shall be designed to ensure the auxiliary engine will not exhaust the fuel supply of the vehicle. (minimum 15-gallon reserve)
A marine grade one way check valve shall be installed in the fuel line to eliminate the possibility of air locks in the fuel line and prevent the inability of the auxiliary pump engine to start instantaneously.

AUXILIARY FIRE PUMP ELECTRIC START WIRING TO CHASSIS
properly sized 12 volt positive and negative cables shall be provided from the chassis battery to the auxiliary fire pump.

AUXILIARY AND MAIN PUMP PLUMBING
The auxiliary fire pump shall be plumbed to the main pump discharge.

AUXILIARY PUMP OIL DRAIN EXTENSION
There shall be an oil drain extension installed on the auxiliary pump. This will allow for the engine oil to be drained without removing the auxiliary engine.

AUXILIARY PUMP COVER
A louvered hinged cover with suitable latches shall be provided over the pump and power unit assembly. The area around the assembly shall remain open for maintenance and air circulation and the radiator shall be located behind ventilated side sheet.

LIGHTING
The specified compartment shall have no compartment lighting'

DOOR AJAR SENSOR
1 0030-0002

Page 31 of 72 ends

10t10122

Page 108 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar.

BYPASS FIRE PUMP COOLER
The fire pump shall be equipped with 3/8" cooling line from the pump to the water tank. This re-circulation line shall be conirolled by a pump panel control valve with nameplate label noting it as the "fire pump bypass cooler".
4'' UNGATED INTAKE.- LEFT SIDE
One (1) 4" un-gated suction intake shall be installed on the left side pump panel to supply the fire pump from an external water supply. The threads shall be 4" NH male and equipped with a removable screen.

One (l) chrome brass 4" NH rocker lug cap with a securing chain or cable shall be installed on the intake.

2.1/2'' GATED INTAKE.- LEFT SIDE
One (l) 2-112" gated suction intake shall be recessed mounted on the left side pump panel to supply the fire pump from an external water supply. The valve shall be a quarter-turn ball valve with the appropriate handle and shall have 2-ll2" NH female thread'
The intake shall be equipped with a South Park Corp. 3/4" Push-pull type drain valve mounted to the bottom of the valve.

One (1) Akron 8825 series swing-out style valve(s) shall be supplied and installed. All valves shallbe designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.

The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle.

One d) chrome brass2-712,'NH rocker lug plug with a securing chain or cable shall be installed on the intake. 2-ll2'GATED INTAKE .. RI SIDE
One (1) 2-112" gated suction intake shall be recess mounted on the right side pump panel to supply the fire pump from an external water supply. The valve shall be a quarter-turn ball valve with the appropriate handle and shall have 2-112" NH female thread.

The intake shall be equipped with a South Park Corp. 3/4" Push-pull type drain valve mounted to the bottom of the valve.

One (l) Akron 8825 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum .nniron-"nts. All valves and controls shall be easily accessible for service, repair or replacement.

The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle.

One d) chrome brass 2-112,' NH rocker lug plug with a securing chain or cable shall be installed on the intake'

WATER TANK SUPPLY LINE TO FIRE PUMP
A 3" water tank to pump line shall be installed, with a 3" full flow quarter turn ball valve and 3" piping. The line shall be equipped with a hump hose with stainless steel hose clamps and a 3" check valve to prevent pressurization of the water tank.
bne (l) Akron 8830 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed 1 0030-0002

Page 32 of 72 ends

10t10122

Page 109 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
to operate under nomal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.

The specified valve shall have a direct actuated 'local' control, Akron Model Rl valve handle.

The 3" valve shall be equipped with an air operated cylinder and control actuator installed on pump panel. The controls shall be located on the left pump operator's panel, be labeled "Tank to Pump", and feature a 'ogreen" valve open and "red" valve closed indicator light.

PUMP TO TANK
There shall be a pump to tank line provided from the discharge side of the pumps and plumbed to the top of the tank. The plumbing shall be 2-inch with a 2-inch Akron 8800 series lo-turn full flow ball valve, and shall be controlled at the left pump panel by a push/pull T-handle and linkage. The pump to tank shall be plumbed to flow water from both the main and auxiliary pumps. Control shall be labeled "Tank Fill".

One (1) Akron 8820 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.

The valve shall be equipped with a Thuemling manually operated pull rod, with quarter-turn locking feature. 2-112" D GE, LEF'T SIDE.- FORWARD PIIMP PANEL
One (l) 2-112" discharge shall be installed on the left side forward pump panel area controlled by a quarter turn ball valve with the appropriate handle. The discharge shall have 2-112" NH male hose threads, bleeder valve, and chrome brass cap, with a label adjacent the control handle.

A Class I quarter-tum3l4" drain and bleeder valve shall be installed on the discharge valve.

One (1) Akron 8825 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.

The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle.

One (l) chrome brass 2.5" NH rocker lug cap with a securing chain or cable shall be installed on the discharge.

2.5'' DISCHARGE .- REAR LEFT
One (l) 2.5" discharge shall be installed on the rear left panel with controlled by a quarter turn ball valve. The discharge shall have 2.5" NH male hose threads and nameplate label adjacent the control handle.

One (1) Akron 8825 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.

The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle. (1) chrome plated brass 30 degree elbow with 2.5" swivel female NH x 2.5" male NH thread with rocker lugs shall be provided on the discharge.

One (1) chrome brass 2.5" NH rocker lug cap with a securing chain or cable shall be installed on the discharge' 2' DISCHARGE .- REAR RIGHT
One (1) 2" discharge shall be installed on the rear right panel, controlled by a quarter turn ball valve on pump panel. The discharge shall have 2" NPT x l-112" NH male hose threads and nameplate label adjacent the valve 1 0030-0002

Page 33 of 72 ends

10110122

Page 110 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
controlhandle.

One (1) Akron 8820 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.

The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle.

One (l) chrome plated brass reducing adapter with a 2" swivel female NH x 1.5" male NH thread with rocker lugs shall be provided on the discharge.

One (l) chrome plated brass 30 degree elbow with 1.5" swivel female NH x l.5" male NH thread with rocker lugs shallbe provided on the discharge.

One (1) chrome plated brass 1.5" NH rocker lug cap with a securing chain or cable shall be installed on the discharge.

I-I12" CROSSLAY DISCHARGES
Two (2) pre-connected 7-112" hose cross lays shall be installed over pump enclosure. One (1) each side. They shall be arranged in a single stack design with a divider in the center of the storage area.Each storage area shall extend from the side of the pump house to the center of the pump house. The dimensions shall be approximately 4-112" wide x 36" deep x32" tall.

Two (2) Akron 8820 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.

The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle.

The crosslay hosebed shall be equipped with an aluminum diamond plate hinged cover and vinyl end flap enclosures on each side, installed in compliance with applicable NFPA #1901 standards. The cover shall be equipped with rubber bumpers and lift up handle on each end of the cover.

The specified crosslay flaps shall be red.

CROSSLAY EDGES
The crosslay side sheets shall be rolled on each side to act as a guide for the hose to come out of the tray.

Two (2) chrome plated brass reducing adapter with a 2" swivel female NH x 1.5" male NH thread with rocker lugs shall be provided on the discharge.

Two (2) chrome plated brass 1.5" NH rocker lug cap with a securing chain or cable shall be installed on the discharge.
1-112'' BUMPER AR.EA DISCHARGE &EFT SIDE)
One (1) 2" discharge shall be provided at the driver's side of the front bumper extension. The discharge shall be plumbed with 2" flexible high pressure hose with reusable fittings or welded stainless steel pipe. The front bumper discharge shall be equipped with a 2" quarter turn ball valve. The discharge shall have a 90 degree full swivel elbow, terminating in l-ll2" NST male threads, to allow the hose to be pulled in any direction without kinking. The swivels shall feature stops allowing them to only rotate 220" from left side to right along the forward radius.

One (1) Akron 8820 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed 1 0030-0002

Page 34 ends

10t10122

Page 111 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.

The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle.

One f ) chrome plated brass 1.5" NH rocker lug cap with a securing chain or cable shall be installed on the discharge.
1-112'' BUMPER AREA DISCHARGE GIGHT SIDE)
One (1) 2" discharge, shall be provided at the passenger's side of the front bumper extension. The discharge shall be plumbed with 2" flexible high pressure hose with reusable fittings or welded stainless steel pipe. The front bumper discharge shall be equipped with a 2" quarter turn ball valve. The discharge shall have a 90 degree full swivel elbow, terminating in l-ll2" NST male threads, to allow the hose to be pulled in any direction without kinking. The swivels shall feature stops allowing them to only rotate 220" from left side to right along the forward radius.

One (l) Akron 8820 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement' The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle.

One d) chrome plated brass 1.5" NH rocker lug cap with a securing chain or cable shall be installed on the discharge.
2'' ISOLATION VALVE
One (l) 2" inline valve, labeled, shall be provided to isolate the front bumper extension discharge piping in the case of a hose or piping failure. This valve shall normally be left in the open position. Control for this valve shall be through the use of a Rl handle, painted red, located at the valve.

One (1) Akron 8820 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum "nnironrn"nts.

All valves and controls shall be easily accessible for service, repair or replacement.

The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle.

HOSE REEL
One (l) Hannay aluminum hose reel Model #SBSEPFI7-28-29-RT shall be installed. The reel shall have leak proof ball bearing swing joint, adjustable friction brake, electric 12 volt rewind and manual crank rewind provisions.,The reel shali be plumbed with wire reinforced, high-pressure hose coupled with brass fittings. The reel shall be designed to hold l25oh of the specified hose capacity' The reel shall be provided with a 12 volt electric motor of appropriate size for rewinding. The hose reel shall have provisions for being rewound manually. The pinion shaft for the manual rewind gear shall be equipped with an adjustable tension brake, controlled at the hose reel.

One (1) Akron 8810 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum .nniron*"nts. All valves and controls shall be easily accessible for service, repair or replacement. 1 0030-0002

Page 35 of 72 ends

10110122

Page 112 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle.

HOSE REEL MOUNTING
The hose reel shall be mounted over the pump enclosure.

Two (2) Cole Hersee #M-608 push button hose reel rewind controls shall be installed supplied and installed to rewind the hose reel. One (1) button shall be installed on the left pump panel and one (1) button shall be installed on the right panel.

HOSE REEL NOZZLE MOUNTING
The specified hose reel nozzle shall be mounted with a PAC nozzle mount. Install the nozzle pocket on the pump panel below the hardline fairlead with two 5/16 bolts.

HOSE REEL ROLLERS
The hose reel shall include one horizontal and two vertical chrome fairlead rollers. Two (2) additional sets of fair lead rollers shall be located on the auxiliary pump cover for guiding the hose across the top of the apparatus.

FOAM SYSTEM
A Foampro electronic foam system shall be provided. The system shall be designed for use with Class A foam concentrate. The foam proportioning operation shall be designed for direct measurement of water flows and shall remain consistent within the specified flows and pressures. The system shall be capable of accurately delivering foam solution as required by applicable sections of the NFPA standards' The system shall be equipped with a control module suitable for installation on the pump panel. There shall be a microprocessor incorporut.d *ithin the motor driver that shall receive input from the system's flowmeter, while also monitoring the foam concentrate pump output. The microprocessor shall compare the values to ensure that the desired amount of foam concentrate is iniected onto the discharge side of the fire pump.A "foam capable" paddlewheel-type flowmeter shall be installed in the discharge side of the piping system.

The control module shall enable the pump operator to
o Activate the foam proportioning system
o Select the proportioning rates from 0.lo/oto l'jYo
o See a "low concentrate" warning light flash when the foam tank level becomes low and in two (2) minutes, if the foam concentrate has not been added to the tank, the foam concentrate pump shall be capable of shutting down.

A l2-volt electric motor driven positive displacement plunger pump shall be provided. The pump capacity range shall be 0.1 to 1.7 GpM (6.4llmin) at200 PSI (13.8 BAR) with a maximum operating pressure up to 400 PSI (27.6 BAR). The system shall draw a maximum of 30 amps at 12 volts. The motor shall be controlled by the microprocessor which shall be mounted to the base of the pump. It receives signals from the control module and 1 0030-0002

Page 36 ends

10t10122

Page 113 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
power the l/3 horsepower (.25 Kw) electric motor in a variable speed duty cycle to ensure that the correct proportion of concentrate is injected into the water stream' A full flow check valve shall be provided in the discharge piping to prevent foam contamination of the fire pump and water tank. A 5 pSI (.35 BAR) opening pressure check valve shall be provided in concentrate line.

Components of the complete proportioning system as described above shall include:
. Operator control module
o Paddlewheel flowmeter
. Pump and electric motor/motor driver
. Wiring hamesses
o Low level tank switch
o Foam tank
r Foam injection check valve
o Main waterway check valve
o Flowmeter and tee with 2" male NPT threads.

The foam system shall be installed and calibrated to manufacturer's requirements. In addition the system shall be tested and certified by the apparatus manufacturer to applicable NFPA standards.

The foam system design shall be tested and pass environmental testing in accordance to SAE standards.

An installation and operation manual shall be provided for the unit. The system shall have a one (1) year limited warranty by the foam system manufacturer.

The Foampro 1600 Series foam system shall be provided with a control cable from the controller to the foam pump assembly.

The Foampro 1600 Series foam system shall be provided with a standard pump panel mounted FoamPro control head.

A Foampro brass flowmeter shall be provided. The flowmeter shall be installed in the "foam capable" discharge line. The flowmeter shall have maximum accuracy between the flow range of 15 GPM and 520 GPM and be capable of operation between 5 GPM to 625 GPM. The tee shall have NPT and Victaulic inlet and outlets connections.

A Foampro instruction and system rating label shall be provided. The label shall display information for a FoamPro 1600 Series foam system and shall meet applicable sections of the NFPA standards' 1 0030-0002
Page37 of72
10t10122

Page 114 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
A Foampro foam system schematic label shall be installed on the pump panel near foam controls. The label shall be a diagram of the FoamPro 1600 series foam system layout and shall meet applicable sections of the NFPA standards.

The foam system will be fastened and mounted from a double gusseted 5/16 steel mount and be supported on the top and bottom of the foam pump system to the buildup'

FOAM SYSTEM OUTLETS
The following discharges shall have foam distributed to them.

Front bumper discharges
Front bumper monitor (if applicable)
Pump house crosslaY Pre connects
Booster hose reel
Rear l-1l2" discharge

FOAM SYSTEM CAB CONTRQL
A FoamPro on-off control switch shall be installed in the cab console.

FOAM UPLOAD SYSTEM
There shall be a Hale EZFoamupfill system supplied and installed on the apparatus. The foam transfer system will be mounted from the frame rail with 1l4-inch steel plate that is gusseted on both ends for support.

PUMP RNCI,OSURE
The pTO fire pump enclosure shall be a separate unit from the body unit and shall be attached and supported at the chassis frame rails. This module shall allow for independent flexing of the pump enclosure from the body, chassis, and tank, and shall permit quick removal. The module shall have Polypro mounting pads and shall be attached to the frame rails. The module shall be a welded frame with all vertical supports from '/t wall 4-36 mild hot rolled steel to be continuous, (no splices or brakes on vertical supports).

The pump enclosure shall be approximately 27" front to rear,72" right to left, and 60" high.

PUMP ENCLOSURE RUNNING BOARD
Both the drivers and passenger side shall be equipped with a side running board a minimum of 12" deep. The running board shall extend along the width of the pump enclosure from the forward end of the body module to behind the chassis cab. The exterior edge of the running board shall be constructed of a non'slip aggressive surface, supported by the pump enclosure framework, and bolted in place with stainless steel fasteners. The outside edges of the specified step shall be provided with 2" x 1.5" x .250" extruded and knurled aluminum rub rails.

Specified part shall include White reflective striping.

PUMP ACCESS SERVICE DOOR.- UPPER LEFT SIDE
1 0030-0002

Page 38 of 72 ends

10t10122

Page 115 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The upper left side of the side mount pump enclosure shall be provided with a pump service access door. The hinged door shall be constructed of stainless steel powder coated satin black, with push button type lever latches for service access.

PUMP PANELS
The pump panels shall be constructed of stainless steel, bolted to the pump enclosure with stainless steel fasteners. The operators side pump panel shall be powdercoated satin black, while the right side panel shall be brushed stainless steel.

MASTER INTAKE PRESSURE GAUGE
One (1) master intake pressure gauge shall be provided on the operator's panel. The gauge shall be a Span brand, or equivalent, 30-0-150 PSI graduated, with a minimum diameter of 4-112", backlit for nighttime operations and silicone liquid filled to prevent condensation inside the gauge and to dampen the movement.

The gauge housing shall be constructed of Zytel nylon with a ll4" NPT brass male fitting centrally located on the rear of the housing. The gauge shall be filled with low-temperature liquid with an operating range of -40 to +150 degrees Fahrenheit, which prevents bouncing ofthe readout needle and provides for an accuracy rating of 3Vo or I" hg on the vacuum side and 5Yo or l5 PSI on the pressure side ofthe gauge.

The gauges shall be wired so when the pump is engaged the gauge light turns on.

The specified gauge shall feature a drain located at the gauge inlet to help prevent freezing. The drain shall be a twist open and close type.

Gauge(s) shall include internal, back-lit 12 volt lighting. Replaceable, Red, LED bulb in a water-resistant holder.

Gauge(s) shall be supplied with a white dial face with black lettering and black gauge marks.

Gauge bezel shall be Chrome in color.

MASTER I) PRESSURE GAUGE
One (1) master discharge pressure gauge shall be provided on the operator's panel. The gauge shall be a Span brand, or equivalent, 0-600 PSI graduated, with a minimum diameter of 4-112", backlit for nighttime operations and silicone liquid filled to prevent condensation inside the gauge and to dampen the movement.

The gauge housing shall be constructed of Zytel nylon with all4" NPT brass male fitting centrally located on the rear of the housing. The gauge shall be filled with low-temperature liquid with an operating range of -40 to +150 degrees Fahrenheit, which prevents bouncing of the readout needle and provides for an accuracy rating of 5o/o or l5 PSI on the pressure side of the gauge.

The gauges shall be wired so when the pump is engaged the gauge light turns on Gauge(s) shall include internal, back-lit 12 volt lighting. Replaceable, Red, LED bulb in a water-resistant holder.
1 0030-0002

Page 39 of 72 ends

10t10122

Page 116 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
Gauge(s) shall be supplied with a white dial face with black lettering and black gauge marks Gauge bezel shall be Chrome in color'

TEST TAPS
Test taps for pump intake and pump pressure with name plate labels shall be provided on the pump instrument panel.

PITESSURE GOVERNOR ANd ENGINE MONITORING DISPLAY
Fire Research pumpBoss series pBA40l-D00 pressure governor and monitoring display kit shall be installed' The kit shall include a control module, intake pressure sensor, discharge pressure sensor, and cables. The control module case shall be waterproof and have dimensions not to exceed 6 314" high by 4 5/8"' The control knob shall be 2,, in diameter with no mechanical stops, have a serrated grip, and a red idle push button in the center. It shall not extend more than I 314" from the front of the control module. Inputs for monitored engine information and outputs for engine control shall be on the Jlg3g databus. Inputs from the pump discharge and intake pressure sensors shall be electrical.

The following continuous displays shall be provided:

Engine npru; shown with four daylight bright LED digits more than ll2" high Check engine and stop engine warning LEDs
Engine oii pressure; shown on a dual color (green/red) LED bar graph display Engine coolant temperature; shown on a dual color (green/red) LED bar graph display Transmission Temperature: shown on a dual color (green/red) LED bar graph display Battery voltage; shown on a dual color (green/red) LED bar graph display Pressure and RPM operating mode LEDs
Pressure / RPM setting; shown on a dot matrix message display Throttle ready LED.

The dot-matrix message display shall show diagnostic and warning messages as they occur. It shall show monitored apparatus information, stored data, and program options when selected by the operator' All LED intensity shall be automatically adjusted for day and night time operation' The program shall store the accumulated operating hours for the pump and engine to be displayed with the push of a button. It shall monitor inputs and support audible and visual waming alarms for the following conditions:

High Battery Voltage
Low Battery Voltage (Engine Off)
Low Battery Voltage (Engine Running)
Hi gh Transm ission TemPerature
Low Engine Oil Pressure
High Engine Coolant TemPerature
Out of Water (visual alarm only'
No Engine Response (visual alarm only).
1 0030-0002

Page 40 of 72 ends

10t10122

Page 117 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The program features shall be accessed via push buttons located on the front of the control module. There shall be a USB port located at the rear of the control module to upload future firmware enhancements.

The governor shall operate in two control modes, pressure and RPM. No discharge pressure or engine RPM variation shall occur when switching between modes. A throttle ready LED shall light when the interlock signal is recognized. The govemor shall start in pressure mode and set the engine RPM to idle. In pressure mode the govemor shall automatically regulate the discharge pressure at the level set by the operator. In RPM mode the govemor shall maintain the engine RPM at the level set by the operator except in the event of a discharge pressure increase. The governor shall limit a discharge pressure increase in RPM mode to a maximum of 30 psi.

Other safety features shall include recognition of no water conditions with an automatic programmed response and a push button to return the engine to idle.

The pressure governor and display shall be programmed to interface with a Cummins engine Intake and discharge pressure transducers, water lines, and gauges which control the pump performance will be protected from freezing to ensure no accidental pump shut down will occur.

An aluminum fold down door and cover made from 1/8 aluminum will be added to the pressure governor that would fold up and lock in place while pumping and will be painted to match the paint on the pump panel. This will protect the governor from the sun and radiant heat on fires.

WATER TANK GAUGE
One (1) Fire Research TankVision model WLA300-4'00-520 tank gauge shall be installed on the pump panel.

The water tank indicator kit shall include an electronic indicator module, a pressure sensor, and a l0' sensor cable. The indicator shall show the volume of water in the tank on nine (9) easy to see super bright LEDs. The gauge shall be interlocked to turn offwhen the parking brake is released and the pump is engaged.

The specified level gauge shall only activate while the park brake is set and the pump is engaged.

WATER TANK GAUGE
One (1) Fire Research TankVision model WLA300-400-520 tank gauge shall be installed on the cab console.

The water tank indicator kit shall include an electronic indicator module, a pressure sensor, and a 10' sensor cable. The indicator shall show the volume of water in the tank on nine (9) easy to see super bright LEDs. The gauge shall be powered when the parking brake is released and the aux pump is engaged.

The specified level gauge shall only activate while the park brake is released and the auxiliary pump is engaged.

WATER TANK VOLUME RT,MOTE INDICATOR
Three (3) Fire Research TankVision model WLA280-A00 tank remote indicator shall be installed. The indicator shall show the volume of water in the tank on Ninety six (96) easy to see super bright Tri-color LEDs. The indicator case shall be waterproof, manufactured of Polycarbonate material with an integrated lens. The package includes a rubber gasket.
1 0030-0002

Page 41 ends

10t10122

Page 118 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
The remote indicator shall receive input information over a datalink from a Fire Research TankVision primary indicator model WLA200-A00, wLA300-400 or WLA400-A00. The remote indicator shall indicate the level as a single color in Red for 25%o or less, Amber color for up to 50% volume, Blue color for up to 75%o volume and Green color for up to 100% volume. When the level reaches 25o/o, the red LEDs will begin flashing. When the level is empty, the red LEDs will scroll in a down-chasing motion and then flash three times. It shall have the program
"upuUitity
to adjust the brightness level for day time and nighttime viewing' One (l) mounted on each side of the cab, on the "C" Pillars' one (l) mounted atthe rear of the apparatus on the drivers side between the handrail and thel-zone bracket, above the BME placard.

The specified level gauge shall only activate while the park brake is set and the pump is engaged.

CLASS A FOAM TANK GAUGE
one (1) Fire Research brand, Model WLA360-A00 tank level gauge shall be provided on the pump operator's panel'to monitor the foam concentrate storage tank level. The gauge shall indicate the foam concentrate storage tank liquid level on an LED bar graph display.

The specified level gauge shall only activate while the park brake is set and the pump is engaged.

NOMENCLATURE PLATES
The apparatus shall be equipped with color coded labels. 5i8-inch X 3-inch metal, Vision Mark individual no-"n.lutureplates shall readily identiff all switches, valves, and controls. The letteringshall be deeply etched; enamel paint filled or anodized aluminum-etchedcolor-coded tags and shall describe the function of all the pump panel controls, switches, discharge and suction valves. The plates shall be attached with stainless steel nytotr nuts and machine screws. The plates shall be attached with stainless steel nylock nuts and machine ,"r"*, (plastic I.D. plates, rivets, adhesive backed plates, andlor self-tapping screws are Unacceptable)' MID PIIMP NE,I,I,I .. DR SIDE,
There shall be three Tecniq brand LED lights installed under a stainless steel light shield mounted above the pump panel. The two outeilights shall be operated by a panel mounted switch, while the middle light will only be activated upon pump engagement.

One (1) of the pump panel lights shall illuminate at the time the fire pump is engaged.

MIDSHIP PUMP PANEL LIGHTS .. PASSENGER SIDE
There shall be one Tecniq brand LED light installed under a stainless steel light shield mounted above the pump panel. The light shall activate upon pump engagement'

PUMP ENCLOSURE WORK LIGHTS
Two (2) LED work lights shall be installed in the pump enclosure. The work lights shall have clear lenses and shall have a control switch.

DESIGN AND SCOPE OF WILDLAND BODY
1 0030-0002

Page 42 ends

10t10122

Page 119 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The body shall be designed and constructed of commonly available structural components for ease of repair and maintenance. The body shall be of a modular design with the body structure independent of the chassis frame rails. The body module shall be mounted to the chassis frame rails utilizing a unique double spring mounting system for flexibility and durability over the lifetime of the apparatus. The fabrication of the body shall be of welded construction to withstand the rigors of fire service use.

The body shall be designed to incolporate and support the tank, hose bed, compartments, and all other equipment intended to be stored in or mounted to the body module. The body skeleton and compartment framework shall be designed of tubular members for increased strength and stress resistance. There shall be no sheet metal or extrusions utilized in the foundation or structural components of the body module due to their critical role in assuring lifetime durability, functionality and usability.

BODY FRAMEWORK
The entire body framework shall be fabricated from steel tubing. The body framework shall be a completely welded unit, forming a connected, stable frame for strength, longevity and providing the skeleton of the body module. The internal upright members of the framework shall act as support for the top layer of the body module. The external upright members shall act as an exoskeleton providing form and support for compartments while acting as the external surfaces of the module. The framework shall define the compartment openings and provide a rigid mounting location for all compartments and doors.

The foundation cross-members shall be placed perpendicular to the chassis frame rails in the wheel well area extending the full width of the body.

All tank support cross members shall be placed to support the water tank as per the tank manufacture's recommendation.

The internal upright supports for top layer components shall be placed to provide support for all components located on the top layer of the body module and shall be constructed of steel tubing.

BODY MOUNTING SYSTEM
The mounting assembly shall be designed to isolate and protect the body module from vibration and twisting stresses imparted by the flexing of the chassis frame rails. The body module shall employ spring loaded body mounting assemblies. Each two piece mounting assembly shall be designed to positively position the body on the frame rails while allowing lateral and forward or aft movement. Mounting assemblies shall be placed forward and rearward of the rear axle as necessary to provide a strong and stable mounting of the body module Each mounting assembly shall consist of a "male" upper mounting bracket and a "female" lower mounting bracket. The upper mounting brackets shall be fabricated from .375 inch thickness steel plate, with .375 inch painted steel lower mounting brackets. There shall be no vertical bends or offsets for strength.

The mounting brackets shall be aligned and connected by two (2) 518 inch diameter grade 8 bolts equipped with 1 0030-0002

Page 43 of 72 ends

10t10122

Page 120 ends

10/25/2022 Item No.12.

Golden State Fire ApParatus
compression springs. The Springs that are used to allow the body to travel up and down shall have a minimum travel of 718 inches on each mount after the spring is compressed with the mounting nuts.

COMPARTMENT FLOOR. SWEEP OUT STYLE
Each compartment shall feature a raised floor sufficient enough so the lip of the compartment shall clear the frame rail of the body module to allow debris to be removed easily from the compartment.

COMPARTMENTATION
All compartments shall be constructed of 14 gauge E.G. steel welded for strength and shall be sealed from the elementi. The compaftments shall be attached to the steel superstructure only, in order to maintain a truly modular design. Each compartment shall feature a smooth edges and surfaces from the walls to each weld without burs or sharp edges in the material.

DRIVER'S SIDE BODY COMPARTMENTS
COMPARTMENT Dl
One compartment shall be provided on the driver's side of the apparatus body above the rear wheels. This compartment shall span from just behind the pump panel to the back of the rear wheel well quarter panel- The compartments approximate "clear door opening" is 51" wide by 39" high with a variable depth of 13'5123".

Compartment shall have two hat sections that are 4.25 inchwide and will be spaced two inches apart that run from either side of the compattment.

COMPARTMENT VENTILATION
A minimum Z-inch single "'Weber" style polished stainless steel swivel vent with four (4) %-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.

COMPARTMENT F'LOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body'

COMPARTMENT SILL PLATE
The compartment shall feature a polished stainless steel sill plate protecting the painted surface of the compartment when items are accessed'

AJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.

Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) horizontal channels on the back wall of the compartment. 1 0030-0002

Page 44 ends

10110122

Page 121 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus

ADJUSTABLE SHELVES
Two (2) adjustable shelve(s) shall be constructed of .188" thick smooth aluminum plate and be mounted in specified compartments with double bolt cast aluminum shelf brackets. Each shelf shall have a broken front edge, and a broken rear edge for added strength and reinforcement. All shelves shall be orbital DA finish.

COMPARTMENT SHELF GRATING
The specified compartment shelf shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is comosion resistant.

The specified Dri-Deck grating shall be black in color.

The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a l-112" minimum in width.

Specified part shall include Red and White DOT approved reflective striping.

COMPARTMENT DIVIDER
There shall be one (l) vertical compartment divider(s) installed in the specified compartment. The divider(s) shall be bolted in place for ease of removal. The aft side of the vertical divider shall have two (2) vertical unistruts installed.

AJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.

GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color.

COMPARTMENT LIGHTING
The specified compaftment shall have two (2) vertical and one (1) horizontal Code 3 800 series lights installed

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar.

COMPARTMENT D2
One full height compartment shall be provided on the driver's side of the apparatus body aft of the rear wheels.

This compartment shall span from behind the rear wheel well quarter panel to the rear of the body in width and from the top of the bodyto the rub rail in height. The compartments approximate "clear door opening" is 34" 1 0030-0002

Page 45 of 72 ends

10t10122

Page 122 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
wide by 58" high with a variable depth of 13.5"122.5". Compartment shall have two hat sections that ate 4.25 inch wide and will be spaced two inches apartthat run from either side of the compartment.

COMPARTMENT VENTILATION
A minimum 2-inch single ".Weber" style polished stainless steel swivel vent with four (4) %-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.

COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body COMPAR SII,I, PI,ATF],
The compartment shall feature a polished stainless steel sill plate protecting the painted surface of the compartment when items are accessed.

ADJUSTABLE SHELVES
Two (2) adjustable shelve(s) shall be constructed of .188" thick smooth aluminum plate and be mounted in specified compartments with double bolt cast aluminum shelf brackets. Each shelf shall have a broken front edge, and a broken rear edge for added strength and reinforcement. All shelves shall be orbital DA finish.

COMPARTMENT SHELF GRATING
The specified compartment shelf shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color.

The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a 1-112" minimum in width.

Specified part shall include Red and White DOT approved reflective striping.

TOOL ON SIDE WALL OF'CO ARTMENT
Two (2) PAC TRAC tool board panel shall be provided and mounted vertically on the side wall of the specified compartment. The tool board shall be mounted directly to the wall and not to unistrut.

TOOL BOARD REAR WALL OF COMPARTMENT
A PAC TRAC tool board panel shall be provided and mounted vertically on the back wall of the specified compartment. The tool board shall be mounted directly to the wall and not to unistrut.

COMP NT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant The specified Dri-Deck grating shall be black in color. 1 0030-0002

Page 46 of 72 ends

10t10t22

Page 123 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus

COMPARTMENT LIGHTING
The specified compartment shall have two (2) veftical and one (l) horizontal Code 3 800 series lights installed.

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compaftment door is ajar.

PASSENGER SIDE BODY COMPARTMENTS

COMPAR NT PI
One compartment shall be provided on the passenger's side of the apparatus body above the rear wheels. This compartment shall span from just behind the pump panel to the back of the rear wheel well quarter panel in width and from the top of the body side to the wheel well in height. The compaftments approximate "clear door opening" is 51" wide by 39" high with a depth of 12". Compartment shall have two hat sections that ate 4.25 inch wide and will be spaced two inches apartthat run from either side of the compartment'

COMPARTMENT VENTILATION
A minimum 2-inch single "'Weber" style polished stainless steel swivel vent with four (4) Yt-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.

COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body.

COMPARTMENT SILL PLATE
The compartment shall feature a polished stainless steel sill plate protecting the painted surface of the compartment when items are accessed.

AJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with fwo (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.

Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) horizontal channels on the back wall of the compartment.

ADJUSTABLE SHELVES
One (l) adjustable shelve(s) shall be constructed of .188" thick smooth aluminum plate and be mounted in specified compaftments with double bolt cast aluminum shelf brackets. Each shelf shall have a broken front edge, and a broken rear edge for added strength and reinforcement. All shelves shall be orbital DA finish.

COMPARTMENT SHELF GRATING
1 0030-0002

Page 47 ends

10t10t22

Page 124 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The specified compartment shelf shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color.

The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a l-112" minimum in width.

Specified part shall include Red and White DOT approved reflective striping.

COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color'

COMPARTMENT LIGHTING
The specified compartment shall have two (2) vertical and one (l) horizontal Code 3 800 series lights installed.

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar.

COMP NT P2
One compartment shall be provided on the passenger's side of the apparatus body aft of the rear wheels. This compartment shall span from behind the rear wheel well quarter panel to the rear of the body in width and from below the walkway to the rub rail in height. The compartments approximate "clear door opening" is 34" wide by 58" high with a variable depth of 12"122". Compartment shall have two hat sections that are 4.25 inch wide and will be spaced two inches apartthatrun from either side of the compartment.

COMPAR VE,NTILATION
A minimum 2-inch single "Weber" style polished stainless steel swivel vent with four (4) %-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.

COMP F'I,OOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body.

COMPARTMENT SILL PLATE
The compartment shall feature a polished stainless steel sill plate protecting the painted surface of the compartment when items are accessed.

AJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide 1 0030-0002

Page 48 ends

10t10122

Page 125 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.

Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) horizontal channels on the back wall of the compartment.

ADJUSTABLE SHELVES
Two (2) adjustable shelve(s) shall be constructed of .188" thick smooth aluminum plate and be mounted in specified compartments with double bolt cast aluminum shelf brackets. Each shelf shall have a broken front edge, and a broken rear edge for added strength and reinforcement. All shelves shall be orbital DA finish'

COMPARTMENT SHELF GRATING
The specified compartment shelf shall be fitted with removable interlocking vinyl Dri-Dek grating' This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck gratingshall be black in color.

The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a l-112" minimum in width.

Specified part shall include Red and White DOT approved reflective striping.

COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant io heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color.

COMPARTMENT LIGHTING
The specified compartment shall have two (2) vertical and one (1) horizontal Code 3 800 series lights installed.

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar'

BACK BODY COMPARTMENTS
COMPARTMENT B1
one compartment shall be provided at the back of the apparatus body, below the hose bed and above the tailboard. This compartmeni shall span just center of the tank. The compaftments approximate "clear door opening" is 27^wide by 34" high with a depth of 25". Compartment shall have two hat sections that are 4.25 inch wide and will be spaced two inches apartthat run from either side of the compartment.

COMPARTMENT VENTILATION
A minimum 2-inch single "'Weber" style polished stainless steel swivel vent with four (4) %-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.
1 0030-0002

Page 49 of 72 ends

10110122

Page 126 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus

COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body.

COMPARTMENT SILL PLATE
The compartment shall feature a polished stainless steel sill plate protecting the painted surface of the compartment when items are accessed.

AJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.

Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) horizontal channels on the back wall of the compaftment.

ADJUSTABLE SHELVES
One (1) adjustable shelve(s) shall be constructed of .188" thick smooth aluminum plate and be mounted in specified compartments with double bolt cast aluminum shelf brackets. Each shelf shall have a broken front edge, and a broken rear edge for added strength and reinforcement. All shelves shall be orbital DA finish.

COMPARTMENT SHELF' GRATING
The specified compartment shelf shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corosion resistant.

The specified Dri-Deck grating shall be black in color.

The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a l-112" minimum in width.

Specified part shall include Red and White DOT approved reflective striping.

COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color'

COMPARTMENT LIGHTING
The specified compartment shall have two (2) vertical Code 3 800 series lights installed.

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar' PUMP HOUSE COMPARTMENT (PHl)
1 0030-0002

Page 50 of 72 ends

10110122

Page 127 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
There shall be a compartment located on the upper passenger side of the pump house. The compartment dimensions shall be approximately 21" wide x 23" high x 12" deep.

COMPARTMENT VENTILATION
A minimum 2-inch single "Weber" style polished stainless steel swivel vent with four (4) %-inch vent holes shall be provided. These vents shall have a stainless steel center bolt to lock the vent in either the open or closed position and be located in the compartment walls. All vents will contain fire resistant filters to minimize dust entering the compartment.

COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body

AJUSTABLE UNISTRUT
Adjustable Uni-Strut equipment mounting tracks shall be installed inside the compartment with two (2) channels on the left wall and two (2) channels on the right wall. The tracks shall be positioned to provide support for equipment mounting. The length of the tracks shall be sized to allow for optimum use of the compartment interior.

ADJUSTABLE SHELVES
One (1) adjustable shelve(s) shall be constructed of .188" thick smooth aluminum plate and be mounted in specified compartments with double bolt cast aluminum shelf brackets. Each shelf shall have a broken front edge, and a broken rear edge for added strength and reinforcement. All shelves shall be orbital DA finish.

COMPARTMENT SHELF GRATING
The specified compartment shelf shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color.

The compartment shelf and or shelves shall have reflective striping added to the outside lip. The stripe shall be a l-112" minimum in width.

Specified part shall include Red and White DOT approved reflective striping.

COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek gratigg. This material shall be resistant to heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color.

COMPARTMENT LIGHTING
The specified compartment shall have two (2) vertical Code 3 800 series lights installed

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar 1 0030-0002
Page5l ol72
10t10122

Page 128 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
PUMP HOUSE COMPARTMENT GH2)
There shall be a compartment located on the lower passenger side of the pump house. The compartment dimensions shall be approximately 11.5" wide x 18" high x 18" deep.

COMPARTMENT VENTILATION LOUVERS
The specified compaltments shall be provided with ventilation louvers. These units shall be approximately 4" to 6" in size to allow exterior air or interior air movement.

COMPARTMENT FLOOR DRAIN
The compartment shall be provided with rear corner floor drains to the underside of the body.

COMPARTMENT GRATING
The compartments shall be fitted with removable interlocking vinyl Dri-Dek grating. This material shall be resistant io heat, cold, ultra-violet radiation, mechanical impacts, chemical actions and is corrosion resistant.

The specified Dri-Deck grating shall be black in color.

COMPARTMENT LIGHTING
The specified compartment shall have two (2) vertical Code 3 800 series lights installed'

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compaftment door is ajar.

SLIDE.IN REAR LADDER COMPARTMENT. PASSENGER SIDE
The rear passenger side of the apparatus body shall have a vertically mounted slide-in ladder storage compartment. The compartment shall be @!g of storing one (1) *20-foot three-section Duo Safety model *gt) ladder, one (1) *backboard minimum dimensions 72" L x 16" W x 2" H (Ferno 'Najo Light NB5500" or similar), one (l) *8-foot long pike pole and one (1) *S-foot digging bar, one (1) *8-foot rubbish hook, *New York Roof Hook with locking pins to secure each item.
*Items are to be purchased by the end user.

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar, SLIDE.IN REAR SUCTION HOSE COMPARTMENTS
Two (2) suction hose storage compartments will be located above the side storage compartments on both sides of the apparatus. The compartments will hold a combined total of three (3) eight (8) foot sections of four (4) inch hard suction hose and strainer.
1 0030-0002

Page 52 of 72 ends

10t10122

Page 129 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
Both compartments will be capable of holding two (2) eight (8) foot sections of hose if needed. Each compartment will have a stainless steel painted hinged door on the rear of the compartment. Each compaftment door will have a locking positive latching door latch.

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compartment door is ajar TOP COMPARTMENT TCl
The hose bed shall be provided with a compartment down the center of the hosebed. The top compartment shall have a one piece aluminum treadplate cover. Approximate "clear door opening" dimensions shall be 13" wide by 75" deep and 16" high.

ALUMINUM TREADPLATE DOOR
This compartment shall feature an embossed aluminum diamond plate lid. The lid shall be bare embossed aluminum diamond plate.

DOOR LATCH
The specified hinged door(s) shall be equipped with a sealed, black lever latch(es). Latch(es) shall be non-locking style.

LIGHTING
The specified compartment shall have no compartment lighting.

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compaftment door is ajar

PAINTED ALUMINUM PANEL
There shall be a smooth aluminum panel bolted to the rear of the center top storage box

WHEEL WELL LINERS
Wheel well liners designed to protect the body from impact resulting from road debris thrown by the tires shall be installed. The removable liners shall be constructed from UHMW material to encompass the entire inner wheel well area. The liners shall be secured with stainless steel threaded fasteners.

REAR WHEEL FENDERT,TTES
Polished stainless steel fenderettes shall be installed at each rear wheel opening. The fenderettes shall be positioned outside of the wheel well panel to cover the tire area that extends past the body. The fenderettes shall be secured with stainless steel threaded fasteners.

DRIVERS SIDE BODY -- SCBA INDE,R STORAGR, PROVISIONS
A storage area for an SCBA cylinder shall be provided in the forward area of the driver's side wheel well Dimensions shall be 8" diameter x 26" deep.
1 0030-0002

Page 53 of 72 ends

10t10t22

Page 130 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
The SCBA door shall be a Cast Products door, the door shall feature a push button on the side to open door.

The SCBA cylinder storage tube shall be made from plastic. There shall be rubber matting to cusion the bottle glued into the tube.

SCBA CYLINDER STRAPS
There shall be a I " nylon tether installed to secure the bottle in the storage tube.

DRIVERS SIDE BODY -- SCBA CYLINDER STOIL{GE PROVISIONS
A storage area for an SCBA cylinder shall be provided in the rearward area of the driver's side wheel well.

Dimensions shall be 8" diameter x 26" deep.

The SCBA door shall be a Cast Products door, the door shall feature a push button on the side to open door.

The SCBA cylinder storage tube shall be made from plastic. There shall be rubber matting to cusion the bottle glued into the tube.

SCBA CYLINDER STRAPS
There shall be a 1" nylon tether installed to secure the bottle in the storage tube' PASSENGER SIDE BODY .. SCBA CYLINDER STOIL{GE PROVISIONS A storage area for an SCBA cylinder shall be provided in the forward area of the passenger's side wheel well Dimensions shall be 8" diameter x 26" deep.

The SCBA door shall be a Cast Products door, the door shall feature a push button on the side to open door.

The SCBA cylinder storage tube shall be made from plastic. There shall be rubber matting to cusion the bottle glued into the tube.

SCBA CYLINDER STRAPS
There shall be a 1" nylon tether installed to secure the bottle in the storage tube.

PASSENGER SIDE BODY.. SCBA CYLINDER STOIL{GE PROVISIONS A storage areafor an SCBA cylinder shall be provided in the rearwardarea of the passenger's side wheel well Dimensions shall be 8" diameter x 26" deep.

The SCBA door shall be a Cast Products door, the door shall feature a push button on the side to open door.

The SCBA cylinder storage tube shall be made from plastic. There shall be rubber matting to cusion the boffle glued into the tube.

SCBA CYLINDER STRAPS
There shall be a 1" nylon tether installed to secure the bottle in the storage tube.

RUB CI,EARANCE LI AND REF'LEC TAPE
The sides of the lower body area fore and aft of the wheel well area shall be provided with 2" x 1.25" x -250" extruded aluminum rub rails, with end caps or angled corners.

Specified part shall include White reflective striping.

F'RONT OF BODY.- PROTECTIVE SURFACE
1 0030-0002

Page 54 of 72 ends

10t10122

Page 131 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The entire front of the apparatus body shall include a protective surface, constructed of aluminum tread plate material.

FRONT RS OF'BODY -- SURF'ACES
The front corners of the apparatus body shall include a protective surface installed. The surface shall be constructed of polished stainless steel material.

REAR BODY PANELS
The entire rear ofthe apparatus body shall be painted apparatus color.

OUTER REAR BODY PANELS -- PROTECTIVE COVERING
The rear outer panels of the body shall have protective surfaces installed on the corners. The protective covering shall be constructed of polished stainless steel material.

TOP OF BODY COMPARTMENTS .- PROTECTIVE SURTA
The top of the side compaftments shall have a protective surfaces installed. The surface shall be constructed of aluminum tread plate material.

ANODIZED AL DRIP RAIL
All enclosed compartment doors shall be provided with an aluminum drip rail above the doors.

ALUMININUM _ COMPARTMENT DOOR. HINGED OVERLAP
One (1) single, vertically hinged door shall be provide and fabricated from aluminum. The frame of the door shall be constructed of 1.75" x 1.75" x.125" aluminum tubing to prevent corrosion and provide structural support. The spacing created by the frame tubing shall filled with Styrofoam for added support, dent resistance, insulation and noise reduction. The exterior surface shall be .125" aluminum for durability. The interior surface shall be .080" aluminum. There shall be no mechanical fasteners, such as bolt heads or rivets on the inside or outside of the doors.

The exterior of the door shall overlap the opening of the compartment. A .75" lip shall be constructed around the opening of the compartment and the exterior of the door. A rubber seal shall be installed on the .75" lip on both the compartment and the door to provide for a double seal against water and dust. A rain gutter shall be mounted above the door creating a third layer of water protection.

The door shall be designed utilizing a D-ring style latch system. A 6" stainless steel D-ring latch, large enough to accommodate a gloved hand, shall be mounted on the exterior of the door. A stainless steel bezel shall be installed to house and protect the D-ring locking mechanism. The easily serviced bezel shall be mounted utilizing stainless steel screws. The D-ring locking mechanism shall be a double catch design. The first catch shall engage to secure the door in the event of improper closure. The second catch shall seal the door from water and other elements once the door has been properly closed. 1 0030-0002

Page 55 of 72 ends

10t10t22

Page 132 ends

10/25/2022 Item No.12.

Golden State Fire APParatus
The door shall be mounted using a stainless steel piano style hinge and a .25" diameter hinge pin for stability.

The vertical hinge shall be mounted to the body frame with threaded inserts and stainless steel screws to preserve functionalify and ease of maintenance in the event of damage.

Gas struts shall be utilized to hold the door in the open position and to prevent the door from slamming during closing. The gas struts shall be mounted directly to the door with a stainless steel bracket assembly for stability and ease of maintenance. The gas struts shall be mounted to the interior of the compartment with a fully adjustable assembly.

The exterior of the compartment doors and the door frames shall be painted to match the body in quality and tone. The interior surface shall not be painted, it shall be sanded utilizing a dual orbital technique' The specified door(s) shall have a Polished stainless-steel D-ring door handle.

The specified door(s) D-ring handles shall be equipped with manual key door locks keyed to use the 1250 key.

COMPARTMENT DOOR EDGE STRIPING
The hinged compartment doors shall have reflective striping applied on the edges. The stripe shall be a l-112" minimum in width.

Specified part shall include Red and White DOT approved reflective striping.

ALUMININUM _ COMPARTMENT DOOR. HINGED OVERLAP
There shall be five (5) double, vertically hinged sets of doors fabricated from aluminum and installed on the apparatus body. Each door shall feature exterior surfaces which overlaps the opening of the compaftment. The exterior surface shall be .125" aluminum for durability and damage resistance. The interior surface shall be .080', aluminum for structural suppoft and overall appealing appearance of the compartment. The frame of the doors shall be constructed of 1.75" x 1.75" x .125" altminum tubing to prevent corrosion and provide structural support. The spacing created by the frame tubing shall be filled with Styrofoam for added support and dent resistance, temperature insulation, and noise reduction' A .75.lip shall be constructed around the opening of the compartment and the exterior of the door. A rubber seal shall be installed on the .7 5" lip of both the compartment and the door to provide for a double seal against water and dust. A rain gutter shall be mounted above the latch type door for an added third layer of water protection.

The doors shall be designed utilizing a D-ring latch system. A 6 inch stainless steel D-ring latch, large enough to accommodate a gloved hand, shall be mounted on the exterior of the door to allow the door to seal and fasten in the closed position. A stainless steel bezel shall be installed to house and protect the D-ring locking mechanism.

The easily serviced bezel shall be mounted utilizing stainless steel screws for added stability of the mechanism and ease of maintenance in the event of damage. The D-ring locking mechanism shall be of a double catch design. The first catch shall engage to secure the door in the event of improper closure. The second catch will seal the door to water and other elements once the doors has been properly closed. 1 0030-0002

Page 56 of 72 ends

10t10122

Page 133 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The doors shall be mounted with a stainless steel hinges with .25" diameter hinge pin for stability. The vertical hinges shall be mounted to the body frame with threaded inserts and stainless steel screws to preserve functionality with use or age and ease of maintenance in the event of damage.

Gas struts shall be utilized to hold the door in the open position and to prevent the door from slamming during closing. The gas struts are mounted directly to the door with a stainless steel bracket assembly for stability and ease of maintenance. The gas struts shall be mounted to the interior of the compaftment with fully adjustable assembly for ease of adjustment and maintenance while increasing stability.

A polished stainless steel scuff guard shall be installed on the bottom of the compaftment opening to prevent damage and wear to the paint and finish of the body module due to the removal and storage to equipment in the compartment.

The exterior of the compaftment doors and the door jambs shall be painted to match the body in quality and tone. The interior of the door shall not be painted due to lack of exposure and inherent resistance to corrosion.

The interior of the door shall be sanded utilizing a dual orbital technique. The sanding shall provide for a smooth, regular, scratch free surface on the interior of the door. The exterior skin to door frame joining seam shall be caulked and painted to provide a moisture proof seal.

Each compartment shall be provided with two vertically hinged doors with one (1) D-ring latch on each door in the set ofdoors.

The specified door(s) shall have a Polished stainless-steel D-ring door handle.

The specified door(s) D-ring handles shall be equipped with manual key door locks keyed to use the 1250 key.

COMPARTMENT DOOR EDGE STRIPING
The hinged compartment doors shall have reflective striping applied on the edges. The stripe shall be a l-112" minimum in width.

Specified part shall include Red and White DOT approved reflective striping.

REAR STEP
The rear bumper shalll be made from aluminum diamondback grip strut. The design of the grip strut shall allow for no debris or dust buildup and will allow for easy clean out with just water.

The step shall be of a three piece design each section to operate independently during body and chassis flexing.

The step will be full body width by a minimum 8-inch deep stand off type. When mounted, the loaded rear departure angle will be no less then22 degrees.

The drop step will have locking positions to allow for up position storage and rear compartment door opening access. The drop step will incorporate a stop in the down position to prevent movement when in use.

AUXILIARY FIXED STEP .. DRIVERS SIDE REAR
1 0030-0002
Page57 of72
10t10t22

Page 134 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
Three (3) Cast Products 8" square cast aluminum auxiliary step(s) shall be provided. The step shall be installed on the rear drivers side of the body.

AUXILIARY D STEP -. PASSENG SIDE, REAR
Three (3) Cast Products 8" square cast aluminum auxiliary step shall be provided. The step shall be installed on the rear passenger side ofthe body.

HANDRAILS
Three (3) knurled type non-slip handrail, approximately 18" in length, shall be vertically installed.

HANDRAILS
Two (2) knurled type non-slip handrail, approximately 42" in length, shall be vertically installed.

HANDRAILS
Two (2) knurled type non-slip handrail, approximately 12" in length, shall be horizontally installed.

HANDRAILS
One (l) knurled type non-slip handrail, approximately 60" in length, shall be horizontally installed.

HOSE BODY CONSTRUCTION SPNCIFICATIONS
The hose bed side sheets and floor shall be constructed from aluminum material. The hosebed shall provide two separate hose beds one on the left and one on the right side ofthe top loaded center dunnage. The hose body shall be free of sharp corners, bolts, or other obstructions that may catch hose and other equipment.

HOSE BED DIVIDER
Two (2) adjustable width hose bed divider constructed from no less than .250 (ll4) aluminum material shall be installed. The divider shall be secured to the hose bed by utilizing adjustable track type channels and fasteners.

The divider shall be full length and depth of the hose bed.

HOSE STORAGE BRACKETS
Two (2) I-Zone hose brackets shall be provided on the rear of the apparatus body, rear-facing, one (1) on each side of the body. Approx length of the I-zone pole shall be24".

ALUMINUM IIOSEBED GRATING
The hose bed compartment deck shall be constructed entirely from maintenance-free, extruded aluminum slats.

The slats shall feature an anodized, contoured, ribbed top surface. The slats shall be of widths approximately 314" highx 4.5" wide and shall be welded into a one-piece grid system to prevent the accumulation of water and allow ventilation to assist in drying hose.

ALUMINUM HOSEBED COVER
Two (2) separate aluminum tread'plate hose bed covers shall be installed, %-inch aluminum alloy diamond plate reinforced with a %-inchaluminum alloy hat section as needed to support walking on the hose bed covers. The 1 0030-0002

Page 58 of 72 ends

10t10122

Page 135 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
covers shall be hinged on the outboard side using full length polished stainless steel hinges with a minimum ,A-inch pin and 1-inch joint length and installed to avoid any hindrance in walking on hose bed covers' The hose bed covers shall have full length handrails installed along the rear lip and one (1) additional grab handle mounted on the top side of the covers and two (2) mechanisms on each cover to assist with opening and closing of the hose bed covers. Each hose bed cover shall have a mechanism to hold the hose bed cover in the open position and will be substantial enough to prevent accidental closing in extreme wind conditions.

The covers shall be reinforced so that they will support the weight of a person walking on the cover and shall be sloped to the outboard side of the apparatus to aid in water run-off.

HOSEBED REAR ENCLOSURE
A vinyl end skirt with two (2) straps per cover, and large quick release buckles (minimum 2-inch) shall be installed on each hose bed cover. Quick release buckles and nylon tie down straps shall be attached to the end skirts. The end skirts will be weighted at the bottom end with a full width flat strip of metal sewn into the hem of the skirt. The end skirts, straps, buckles, etc. will be exposed to direct sun light and shall be protected against IJV rays.

The flaps shall be black in color.

HOSEBED .. AREA LIGHTS
(4) Tecniq El0lights shall be provided and installed on hosebed door(s)

DOOR AJAR SENSOR
The Specified door(s) shall feature a magnetic proximity switch to indicate when the compafiment door is ajar'

WATER TANK CIF'ICATIONS
A United Plastics Fabricating (UPF), 500 gallon booster tank (Poly Tank) shall be fabricated from a minimum of .500" polypropylene complete with a minimum of .3T5" polypropylene internal full height baffles that are raised 4" off the tank floor for maximum water flow between baffles. In addition, provisions for the main pump outlet, direct tank filler inlet, a pump to tank filler/churn valve inlet, aback pump filler outlet, afftting for an electronic water level gauge sensor and clean outs for manual tank flushing shall be provided. The tank shall be structurally reinforced and restrained to prevent deformities or damage to the tank or apparatus body during stressed off road operations. The booster tank shall be a rectangular design, and shall be capable of being completely removable from the body without cutting or bending of any components. The tank and cradle assembly shall be mounted to the chassis frame in strict accordance to the tank manufacturer's installation guidelines.

The water tank shall be constructed of polypropylene, nitrogen-welded and tested inside and out. The tank manufacturer shall define the floor, top, sides, ends, and baffles material thicknesses. The tank shall carry a lifetime warranty. The water tank shall be manufactured by United Plastic Fabrication.

The transverse and longitudinal swash partitions shall be interlocked and welded to each other as well as to the walls of the tank. The partitions shall be designed and equipped with vent holes to permit air and liquid 1 0030-0002

Page 59 of 72 ends

10t10122

Page 136 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
movement befween compartments. The .cover shall be recessed .375" from the top of the side walls. Hold down dowels shall extend through and be welded to both the covers and the transverse partitions, providing rigidify during fast fill operations. Drilled and tapped holes for lifting eyes shall be provided in the top area of the water tank.

The water tank manufacturer shall certiff the capacity of the water tank prior to delivery of the apparatus. This capacity shall be recorded on the manufacturer's record of construction and the certification shall be provided to the purchaser when the apparatus is delivered. Tank construction shall conform to applicable NFPA standards.

The water tank shall be configured in a rectangular style with consistent widths on the sides from top to bottom.

TANK FILL AND OVERFLOW PROVISIONS
The water tank shall have a combination vent and manual fill tower. The fill tower shall be fabricated from ll2" polypropylene and shall have a minimum outer perimeter dimension of 8" x 8". The tower shall have a 714" thick polypropylene screen and a polypropylene hinged cover. Inside the fill tower, halfway down from the top, shall be fastened a vent overflow pipe. The vent overflow shall be fabricated from Schedule 40 polypropylene pipe, with a minimum I.D. of 4". The vent overflow shall be designed to run through the tank interior and shall be designed to exit the water tank interior behind the rear wheels.

The tank cover shall be fabricated from ll2" thick pollpropylene and shall incorporate a three-piece design which allows for the removal of each individual cover section for inspection or repair of the tank interior, if necessary. The tank cover shall be recessed 3/8" from the top of the tank sides and shall be welded to both the sides and the longitudinal baffles. Each of the three cover sections shall have hold downs to assist in keeping the cover rigid under fast filling conditions. These hold downs shall consist of 2" polypropylene dowels, spaced a maximum of 30" apart, fitted and then welded to the transverse partitions. The dowels shall extend through the cover sections and be welded to them. Two of the dowels shall be drilled and tapped to accommodate the tank lifting eyes.

The sump shall have a minimum dimension of 8" x 6" with a 3l4" thick bottom. On all tanks with a bulkhead suction inlet, a 3" Schedule 40 polypropylene pipe sweep shall be provided from the front of the tank to the sump location. The sump shall have a threaded plug located at the bottom of it for a tank drain and clean out.

There shall be two standard tank outlets: one for the tank to pump suction line, which shall be a minimum of a 3" NPTF coupling, and one for a tank fill line, which shall be a minimum of a l-712" NPTF coupling. All tank fill couplings shall be backed with flow deflectors to break up the stream of water entering the tank.

The water tank shall rest on the body subframe cross members, which shall be spaced a maximum of 22" apart.

The tank shall be insulated from those cross members by hard rubber insulators, with a minimum thickness of 1/4", glued and mechanically fastened to the cross members to protect the tank from direct contact with the steel body subframe. The tank shall be designed on a free-floating suspension principle and shall not require the use of additional hold downs. The tank shall be completely removable without disturbing or dismantling the apparatus body strucfure.

VENT AND OVERFLOW
1 0030-0002

Page 60 of 72 ends

10t10t22

Page 137 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The fill tower shall incorporate avent and overflow system shall be designed into the watertank' The system shall include a 3" diameter PVC pipe that functions both as an air vent while emptying the tank and as an overflow when filling the tank. The overflow shall discharge excess water below the frame rails of the vehicle.

TANK SUMP AND DRAIN PROVISIONS
A one (l) cubic foot (minimum) polypropylene sump, with anti-swirl baffles shall be provided. The sump shall be located as close to the center of the tank floor as the chassis cross members, and differential driveline will allow.

One (l) 3-inch or 4-inch National Pipe Thread (NPT) outlet and plug shall be provided in the sump floor for flushing of the tank. A lVz-inch drain valve shall be provided in the tank sump for flushing of the booster tank.

The valve will be located as to provide for adequate clearance from cross members and differential during extreme twisting motions of the chassis and buildup
The sump shall also be provided with a 1-inch NPT outlet for the back pump filler hose.

Due to space constraints, it may be necessary to locate the main pump suction outlet in the tank sump for maximum water usage. The main pump suction tube will be of an adequate size to supply the main pump with enough water to meet pump ratings.

A minimum 3-inch direct tank fill NPT inlet and internal manifold shall be provided on the left rear of the tank.

If the direct tank fill inlet is located on the rear tank wall, the inlet manifold shall pass through the first baffle and feature a tum down to eliminate any possible damage to the tank or baffles while filling the tank.

WATER TANK AIN PROVISIONS
A 3" plugged drain provision shall be installed in the bottom of the water tank, sump, or plumbing for water tank draining and the flushing-out of debris.

CLASS A FOAM TANK SPECIFICATIONS
The Class A foam tank shall have a capacity of 20 gallons. The foam tank shall be manufactured by UPF and have a lifetime warranty.

The tank shall be equipped with a positive sealing pressure/vacuum vent type cap, a low foam concentrate sensor that turns off the foam pump at a pre-set level, a visual sight gauge, an easily accessible brass or stainless steel drain valve located at the lowest point of the foam tank and an accessible brass or stainless steel cleanable strainer installed in the supply line from the foam tank to the foam pump.

The foam tank shall be mounted on a removable sub-structure. The tank will have a positive tie down. The tie down will allow for easy removal of the foam tank'
1 0030-0002

Page 61 of 72 ends

10t10t22

Page 138 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The foam tank will have two (2) quarter turn brass or stainless shut off valves at the pump supply and fill lines to allow for the removal of the tank without loss of foam. The float switch harness and the foam concentrate supply and fill lines shall have connections located adjacent to the tank to facilitate foam tank removal.

F'OAM TANK FILL AI\D VENTING PROVISIONS
The foam concentrate tank shall be provided with a fill pipe having a volume of not less than 2petcent of the total tank volume. The filler opening shall be capped with a sealed air-tight threaded cover. The fill opening shall be designed to incorporate a removable screen and shall be located so that foam concentrate from a five (5) gallon container can be dumped into the tank.

The foam tank filler shall be equipped with a pressure/vacuum vent that enables the tank to compensate for changes in pressure or vacuum when filling or withdrawing foam concentrate from the tank. The pressure/vacuum vent shall not allow atmospheric air to enter the foam tank except during operation or to compensate for thermal fluctuations. The vent shall be protected to prevent foam concentrate from escaping or directly contacting the vent at any time. The vent shall be of sufficient size to prevent tank damage during filling or foam withdrawal.

A color coded label or visible permanent marking that reads "CLASS A -- FOAM TANK FILL" shall be placed at or near the foam concentrate tank fill opening. An additional label shall be placed at or near any foam concentrate tank fill opening stating the type of foam concentrate the system is designed to use.

Any restrictions on the types of foam concentrate that can be used with the system shall also be stated, along with a warning message that states "WARNING: DO NOT MD( BRANDS AND T\?ES OF FOAM." A 314" diameter connection, piping, and gate type valve shall be installed for the foam tank for draining purposes.

DIRECT TANK F'ILL . RRAR DRIVE,RS SIDE
A valve for direct filling of the tank shall be supplied.The ll4 turn valve shall be configured with 2-112" NH female threads, debris screen, threaded plug with retention chain and lever handle. The valve shall be located on the drivers side rear ofthe apparatus.

One (l) Akron 8825 series swing-out style valve(s) shall be supplied and installed. All valves shall be designed to operate under normal conditions up to 500 PSI and shall have dual seats to work in both pressure and vacuum environments. All valves and controls shall be easily accessible for service, repair or replacement.

The specified valve shall have a direct actuated 'local' control Akron Model TSC valve handle.

One (1) chrome brass 2-112" NH rocker lug plug with a securing chain or cable shall be installed on the intake. (l) chrome plated brass 30 degree elbow with 2.5" swivel female NH x 2.5" rnale NH thread with rocker lugs shall be provided on the direct tank fill.

BACK PACK I, SYSTE,M
There shall be one (1) back pack fill system provided and installed on the lower area of the pump panel. The valve plumbing shall be 314" I.D. hose.
12 VOLT ELECTRICAL SPECIFICATIONS
1 0030-0002

Page 62 of 72 ends

10t10t22

Page 139 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The following describes the low voltage electrical system on the apparatus including all panels, electrical components, switches and relays, wiring harnesses and other electrical components. The apparatus manufacturer shall conform to the latest Federal DOT standards, current automotive electrical system standards, and the applicable requirements of the NFPA 1906.

Wiring shall be stranded copper or copper alloy conductors of a gauge rated to carry 125 percent of the maximum current for which the circuit is protected. Voltage drops shall not exceed l0 percent in all wiring from the power source to the using device. The wiring and wiring harness and insulation shall be in conformance to applicable SAE and NFPA standards. The wiring harness shall conform to SAE J-l128 with GXL temperature properties. Exposed wiring shall be run in a loom with a 290 degree Fahrenheit rating. Wiring looms shall be properly supported and attached to body members. Electrical conductors shall be constructed in accordance with applicable SAE standards, except when good engineering practice requires special construction.

All wiring connections and terminations shall provide positive mechanical and electrical connections and be installed in accordance with the device manufacturer's instructions. When wiring passes through metal panels, electrical connections shall be with mechanicaltype fasteners and rubber/plastic grommets.

Wiring between cab and body shall be split using Deutsch type connectors or enclosed in a terminal junction panel allowing body removal with minimal impact on the apparatus electrical system. Connections shall be insulated with heat shrink crimp-type tubing to resist moisture and foreign debris such as grease and road grime.

Weather resistant connectors shall be provided throughout the system' Electrical junction or terminal boxes shall be weather resistant and located away from water spray conditions.

When required, automatic reset breakers and relays shall be housed in the main body junction panel.

There shall be no exposed electrical cabling, harnesses, or terminal connections located in compartments, unless enclosed in an electrical junction box or covered with a removable electrical panel. Wiring shall be secured in place and protected against heat, liquid contaminants and damage and shall be uniquely identified at least every six inches (6") by color coding or perrnanent marking with a circuit function code and identified on a reference chaft or electrical wiring schematic per requirements of applicable NFPA 1906 standards.

Low voltage protective devices shall be provided for the electrical circuits. The devices shall be accessible and located in required terminal connection locations or weather resistant enclosures. Over current protection devices shall be automatic reset type suitable for electrical equipment and meet SAE standards. All electrical equipment, switches, relays, terminals, and connectors shall have a direct current rating of 125 percent of maximum current for which the circuit is protected. Electro-magnetic interference suppression shall be provided in the system as required in applicable SAE standards'
The electrical system shall include the following:
1 0030-0002

Page 63 of 72 ends

10t10t22

Page 140 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
Electrical terminals in weather exposed areas shall have a non-conductive grease or spray applied. All terminal plugs located outside of the cab or body shall be treated with a corrosion preventative compound.

All electrical wiring shall be placed in a protective loom or be harnessed.

Exposed connections shall be protected by heat shrink material and sealed connectors.

Large fender washers shall be used when fastening equipment to the underside of the cab roof and all holes made in the roof shall be caulked with silicone.

Electrical components installed in exposed areas shall be mounted in a manner that will not allow moisture to accumulate inside.

A service loop shall be provided behind an electrical appliance to allow them to be pulled away from mounting area for inspection and service work.

Upon completion of the vehicle and prior to delivery, the apparatus shall be electrically tested and the electrical testing, certifications, and test results shall be submitted with delivery documentation per requirements of NFPA 1906.

ELECTRICAL ING HARNE,SS
The electrical system shall be divided into separate harnesses. The individual harness shall be connected with Deutsch type quick connectors. The wiring and appliances shall be protected by automatic reset type circuit breakers.

CUSTOM ATED CONSOI,F],
A custom fabricated electrical console and enclosure shall be located befween the driver's and the officer's seating positions. The center console will contain*two* USB dual 2.1-amp dual inlet charging ports one on the side of each seat in the front and two in the rear of the center console facing back on either side of the console.

USB CHARGIN(] PORT
Four (4) USB charging porl(s) shall be installed in the cab of the truck for the fire departments accessory devices. The USB charging port shall have two (2) USB connections and shall have a 5 volt, 4.8A output with Intelligent Device Recognition capabilities.

The specified power source shall be wired battery hot.

SPARE WIRING
Five (5) pair of spare wiring shall be provided. One wire shall be t2-volt battery switched controlled and the other shall be a 12-volt, 15-amp fused ignition switch controlled circuit.

The wiring shall be labeled as to their function, coiled, and located within the center console and behind the rear seat. Additional ignition and battery fuse panel (blue sea style) shall be included and will terminate in the center console.

BATTERY SWITCH. MASTER DISCONNECT
1 0030-0002

Page 64 of 72 ends

10t10t22

Page 141 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
A battery cutoff switch shall be provided in the cab within easy reach of the driver; by the chassis manufacturer.

There shall be a200amp continuous rated solenoid installed and switched by the OEM battery master switch. 150 AMP CIRCUIT BREAKER
A "Class l " (or equal) 150-amp circuit breaker shall be located between the master battery switch and the sub-panel. The 15O-amp circuit breaker shall be located in an enclosed compartment with a removable door with four bolts that will be located in the battery box.

The wiring going to and from the circuit breakers will be insulated with loom and have rubber grommets where the wiring passes through metal compartments. All terminals on this panel shall be properly labeled and numbered with permanent, moisture and heat resistant material.

BATTERY CHARGER
A Kussmaul Autocharge 1200 PLC, model #091-187-12, automatic battery charger shall be provided. The battery charger shall be wired to the 12 volt battery system. Charger maintainer will be installed behind the rear seat driver's side. This area will be enclosed with l/8-inch aluminum with a bolt on access cover with four bolts for servicing and have two 120-volt muffin fans on one side with equal breathing diameter holes on the opposite side that are activated when the engine is plugged in to 120 volts'

KUSSMAUL SUPER AUTO EJECT DELUXE COVER
There shall be a Super Auto Eject with Deluxe Cover with Digital Display installed. The Super Auto Eject shall be a 120V, 154 eject. The digital display shall show volts and amps. Super Auto Eject shall be installed on the drivers' side of the cab with a3116 aluminum plate that has gussets installed on the angle bracket below the door and jam and not contacting the frame or battery box.

The specified auto eject cover shall be red

IDENTIFICATION LIGHTS
All LED identification lights shall be installed on the vehicle as required by applicable highway regulations

LICENSE PLATE MOUNTING
A front, predrilled license plate position shall be installed in the front bumper if permissible to the design Passenger side.

LICENSE PLATE MOITNTING AND LIGHT
A predrilled backing plate and LED light shall be installed on the rear for mounting of the license plate.

STOP. TAIL. LIGHTS
Two (2) Peterson #8l7KR-7 4" LED lights shall be installed as stop/tail lights on the rear of the apparatus. They shall be grommet mounted.

TAIL IGHTS
1 0030-0002

Page 65 of 72 ends

10t10122

Page 142 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
Two (2) Peterson #8l7KR-7 4" LED lights shall be installed as turn signal lights on the rear of the apparatus above the stop/turn lights. They shall be grommet mounted.

BACK UP LIGHTS
Two (2) Peterson #M81 7C-7 4 LED lights shall be installed as back up lights on the rear of the apparatus. They shall be grommet mounted.

ZONE C- LOWER REAR
Two (2) Whelen M6 Series Model # M6RC warning light shall be provided. The waming light shall incorporate Linear Super-LED@ and Smart LED@ technology. The M6RC configuration shall consist of 18 red Super-LEDs and a clear optic polycarbonate lens.

The lens/reflector assembly shall be sealed and resistant to water, moisture, dust, and other environmental conditions. The hard coated lens shall provide extended life/luster protection against UV and chemical stresses.

The specified Whelen M6 lights shall be equipped with chrome plastic flange type light bezel mountings.

MAP LIGHT
One (l) Havis Shields #C-MAP-T-LED 12" LED map light, 12 volt, with a gooseneck arm an on-off switch located on the base of the light shall be installed on the dashboard'

FRONT BUMPER -- GROUND LIGHTS
There shall be two (2) Tecniq E10, LED ground light(s) installed under the front bumper. The lights shall activate by a button located on the Cencom core control head, and any time a cab door is opened.

CAB GROUND LIGHTS
There shall be four (4) Tecniq El0, LED ground lights installed under the cab door(s). The lights shall activate by a button located on the Cencom core control head, and any time a cab door is opened.

GROUND LIGHTS . PUMP PANEL
There shall be two (2) Tecniq E10, LED ground lights installed under the pump panel running board(s). The lights shall activate by a button located on the Cencom core control head, and any time a cab door is opened.

GROUND LIGHTS .IINDER REAR STE,P
There shall be two (2) Tecniq El0, LED ground lights installed under the rear step area. The lights shall activate by a button located on the Cencom core control head, and any time a cab door is opened.

PIONEER MICRO
There shall be six (6) Whelen Pioneer Micro lights provided and installed on the apparatus. 1 0030-0002

Page 66 of 72 ends

10t10t22

Page 143 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
The lights shall be located:
r One located on each side of the pump house recessed into upper panels. Controlled by "Left Scene" and Right Scene switches on the Whelen siren controller
r Two located under the middle steps on the back of the apparatus. They shall be operated by the "Rear Scene" switch located on the Whelen siren controller
a Two (2) mounted rear facing under the rear of the body

FRONT BUMPER BEZEL
The center of the front bumper shall feafure abezel, the bezel shall trim out around the front tow plate and front Whelen Micro Pioneer lights and have an BME logo. The BME logo shall have reflective material behind it.

REFLECTIVE BACKGROUNI)
Part shall feature a Red reflective background.

The scene lights shall be activated by individual buttons or switches on the cab center console. Left, right, and rear scene light controls.

PIONEER PLUS SCENE LIGHT
There shall be two (2) Whelen Pioneer Plus model# PCHIPI with a switch and pole/pedestal mount located on the rear of the apparatus. The light heads shall be white in color. The light's shall be supplied with battery switched power, and be activated with the included light mounted switch.

TOMAR 3O'' LIGHTBAR
(1) Tomar TRX thirty inch 30" lightbar Model# TRX-3OW-AC shallbe installed as specified on the apparatus.

The lightbar shall emit White and Amber light.

FRONT BUMPER B.F"ZF,L
The center of the front bumper shall feature abezel, the bezel shall trim out around the front tow plate and front Tomar 30" TRX light bar.

The scene lights shall be activated by individual buttons or switches on the cab center console. Left, right, and rear scene light controls.

DOOR OPEN RNING I,IGHT
The door ajar warning system shall be separated into four zones, aLeft, Right, upper hosebed area, and Rear zone. Each zone shall have an individually labeled warning light and also activate an audible alarm. The door ajar lights and audible alarm shall activate only when the apparatus parking brake has been released.

RADIO SPEAKERS MOUNT
1 0030-0002
Page67 of72
10t10t22

Page 144 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
An interior cab ceiling mounted box shall be installed and be pre wired, routed to the center console. The box shall be big enough to mount a speaker and be powder coated black.

RADIO INSTALLATION
There shall be four (4) radio antenna installed on the apparatus and routed to the cab center console.

BACK UP ALARM
One (l) solid state back up alarm shall be provided at the rear of the apparatus. The back up alarm shall be wired to the reverse circuit of the transmission, and shall provide an audible alarm to the rear of the apparatus when reverse gear is selected. The alarm shall have a volume of 87 to ll2 db while in operation.

BACK UP CAMERA
There shall be a Rear View Safety back up camera system supplied and installed on the apparatus. The camera system shall consist of a7" TFT LCD Digital Color Display, l30o Ultra Wide Angle Back Up Camera. Part# RVS-770613-HD. A reverse sensing RVS-770613HD auto dimming back up camera system shall be installed with a seven-inch monitor.

The camera for this system will be mounted in the dead box facing rear between hose beds coyers. *The camera screen will be located in the open compartment facing rear in the dash'* This camera will not contact the stacked CAL FIRE stacked logo.

HEADLI F'I,ASHER
The white portion of the Whelen, M6DD light heads shall be programmed to function as the wig wags. It shall be activated in the "calling for the right of way" mode and be turned off in the "blocking of the right of way'' mode by applying the parking brake. Should the feature need to be interrupted, the wig wags shall also incorporate a separate cut off switch on the Whelen CORE control head.

ELECTRONIC SIREN
A Whelen CenCom Core C399 electric siren and lighting control module shall be installed. The siren shall be wired through the siren control head and the OEM horn ring and be activated only when the *calling for the right of way* function has been activated.

WHELEN CORE CONTROL HEAD
There shall be a Whelen model CCTL6 control head supplied with the Cencom Core system. It features a 3 section control head, with 8 push buttons, 4- position slide switch with a 7 position rotary knob. A manual siren and air horn button, and 3 traffic advisor control buttons.

WHELEN CORE WECANX TRAFFIC ADVISOR MODULE
1 0030-0002

Page 68 of 72 ends

10t10t22

Page 145 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
There shall be a Whelen model CTA Traffic Advisor module interfaced with the Cencom Core system

SIREN SPEAKER
One (1) Whelen Model #SA3l5P siren speaker shall be provided. The 100 watt siren speaker shall be designed in a black nylon composite housing with 123 decibel rating.

ZONE A FRONT UPPER -- LIGHTBAR
One (l) Whelen Model #TB-CALFIRE-ECT-M34 Cenator series WeCanx light bar shall be installed on the apparatus. The lightbar shall feature the following:

Eight forward facing RED/WHT LIN6 lights
Two forward facing LED take down lights.

A left and right facing LED take down light.

Four corner RED/WHT LIN6 lights.

Two rear facing RED/AMBER LIN6 lights.

ZONE A.. LOWER FRONT WARNING LIGHTS
Two (2) Whelen M6 Series Model # M6D warning light shall be provided. The red portion shall be used as a front warning light and the white portion shall be used as front wig wags as well as additional area lighting when needed.

The specified Whelen M6 lights shall be equipped with chrome plastic flange type light bezel mountings.

ZONE A -- LOWER WARNING I,IGHTS
Two (2) Whelen WIONSMCR lights shall provided and installed on the front face of the bumper, towards the outer edge.

ZONE B AND D-. F'RONT INTERSECTION
Two (2) Whelen M6 Series Model # M6RC warning light shall be provided. The waming light shall incorporate Linear Super-LED@ and Smart LED@ technology. The M6RC configuration shall consist of l8 red Super-LEDs and a clear optic polycarbonate lens.

The lens/reflector assembly shall be sealed and resistant to water, moisture, dust, and other environmental conditions. The hard coated lens shall provide extended life/luster protection against UV and chemical stresses The specified Whelen M6 lights shall be equipped with chrome plastic flange type light bezel mountings.

ZONE B AND D.. LOWER MID BODY
Two (2) Whelen M6 Series Model # M6RC warning light shall be provided. The warning light shall incorporate Linear Super-LED@ and Smart LED@ technology. The M6RC configuration shall consist of l8 red Super-LEDs and a clear optic polycarbonate lens.

The lens/reflector assembly shall be sealed and resistant to water, moisture, dust, and other environmental conditions. The hard coated lens shall provide extended life/luster protection against UV and chemical stresses.

The specified Whelen M6 lights shall be equipped with chrome plastic flange type light bezel mountings. 1 0030-0002

Page 69 ends

10t10t22

Page 146 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
ZONE B AND D.. UPPER REAR CORNER
Two (2) Whelen M6 Series Model # M6RC warning light shall be provided. The waming light shall incorporate Linear Super-LED@ and Smart LED@ technology. The M6RC configuration shall consist of 18 red Super-LEDs and a clear optic polycarbonate lens.

The lens/reflector assembly shall be sealed and resistant to water, moisture, dust, and other environmental conditions. The hard coated lens shall provide extended life/luster protection against UV and chemical stresses.

The specified Whelen M6 lights shall be equipped with chrome plastic flange type light bezel mountings.

ZONE C -. UPPER REAR WARNING LIGHTS
Two (2) Whelen M6 Series Model # M6K waming light shall be provided. The warning light shall incorporate Linear Super-LED@ and Smart LED@ technology. The M6K configuration shall consist of 18 Super-LEDs and a clear optic polycarbonate lens.

The lens/reflector assembly shall be sealed and resistant to water, moisture, dust, and other environmental conditions. The hard coated lens shall provide extended life/luster protection against UV and chemical stresses.

The M6K light shall include a split design including red and amber LEDs, with a clear lens The specified Whelen M6 lights shall be equipped with chrome plastic flange type light bezel mountings.

REAR TRAF'F'IC F:,IGHT (8) I,.E-D. I,AMPS
A Whelen TAZ86 eight lamp LINZ6 Super-LED Traffic Advisor with all amber lights shall be provided and mounted at the rear of the body. The solid state traffic advisor shall include model TACTL5 control head, or it can be directly connected to a Whelen CenCon Siren Head Controller.

PAINTING -- EXTERIOR CAB /
The exterior of the chassis cab shall be a single tone finish painted by the final stage manufacturer

BODY PAINTING SPECIFICATIONS
All exposed surfaces shall be prepared and painted using a multi-step process to ensure a blemish-free, protective coating for the base metal materials.

All removable items, such as brackets and compartment doors, shall be removed and painted separately to insure finish paint behind them after they are reinstalled.

Due to its modular design, the apparatus body shall be completely finish painted prior to its installation on the chassis.

The body shall be sanded, and cleaned. Any imperfections or defects in the metal shall be corrected with premium body filler and then sanded smooth.

An epoxy primer shall be utilized on all painted and coated surfaces and shall prepare the metal for the final paint. The direct-to-metal primer shall be used to create a first level seal allowing secure adhesion between the 1 0030-0002
Page70 of 72
10t10t22

Page 147 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
base metal and the subsequent substrates
All body and components shall then be primed, thoroughly sanded, and meticulously inspected for any imperfections ; which shall be properly corrected..

All surfaces shall then be painted with a base coat of premium paint following the guidelines as established by the paint manufacturer. The body shall be painted using a single color to match the cab primary color, and then shall be buffed to a high gloss finish.

INTERIOR F'INISH
The interior wall, floor and ceiling surfaces of compartments shall be finished with Rust-Oleum brand Multispec color flecked paint. The final color combination shall be determined in pre-con.

The specified compartment(s) shall be coated with Gray Stone colored Multi-Spec paint.

TOUCH.UP PAINT
Touch-up paint shall be furnished with the completed truck at final delivery

VALVE PAINTING
All exposed valves shall be painted to match the color of the exterior body

MISC PAINTING
The fuel tank support brackets, air tanks and mounting brackets shall be painted job color red CAL.F'IRE STRIPING PACKAGE
The following graphics shall be provided:
. Three (3) reflective stripes will be provided across the front of the vehicle and along the sides of the body. The reflective band will consist of a 1 .00" white stripe at the top with a 1.00" gap then a 8.00" White stripe with a 1.00" gap and a

1.00" white stripe on the bottom.
. 4" high black reflective band across face of bumper
. There will be alternating diamond grade chevron striping located on the rear-facing vertical surface of the apparatus. The entire rear surface, including the rear compartment doors, will be covered. The colors will be red and trellow. Each stripe will be 6.00" in width.
. The reflective band located on each side of the apparatus body will contain one (1) iog(s) and will be angled at approximately a 45 degrees when installed.
. A white reflective stripe will be provided on the interior of each cab door. . six (6") inch white reflective letter with black outline and shade reading "CITY OF FOLSOM" installed on each side of body between fonrvard scene light and rear warning light. Top of graphics straight with bottom of graphics arched. Font to match Pierce job 34002
. four (4") inch white reflective letter with black outline and shade reading "ENGINE 334" installed on each side of body between forward scene light and rear warning light under CITY OF FOLSOM letteirng. 1 0030-0002
Page7l of72
10t10t22

Page 148 ends

10/25/2022 Item No.12.

Golden State Fire Apparatus
. Four inch white reflective letter with black outline and shade on approximately 15" x 6" red painted plate on right side bumper reading "FOL"
. Four inch white reflective letter with black outline and shade on approximately 15" x 6" red painted plate on left side bumper reading "E334" (engine number yet to be defined) . Three inch white reflective letter with black outline and shade on approximately 14.5" x 4.5" red painted plate on right side rear body reading "E334" (engine number yet to be defined) . Sixteen inch black reflective letters on cab roof reading "FOL" e (1) 17" Reflective Folsom Logo with .5" cutout of stripe on each cab door NO-Cal-Fire Equipment Package
5# DRY CHEMICAL FIRE EXTINGUISHER
One (1) 5# ABC dry chemical fire extinguisher and mounting bracket shall be provided on the apparatus. The extinguisher shall have a pressure gauge and shall be filled with a dry chemical extinguishing agent.

HYDRATILIC JACK
One (l) hydraulic jack shall be provided. The jack shall be designed for lifting capacity of twelve (12) tons

LUG WRENCH
There shall be one (1) lug wrench provided artd shipped loose with the completed apparatus Cal-Fire Tag On Adjustment
1 0030-0002

Page 72 ends

10t10122

Page 149 ends

10/25/2022 Item No.12.

GOLDENSTATE

FIRE APPARATUS
DEALER

SUPPLIED

EAUIPMENT
AND/OR

SERVIGES

Page 150 ends

10/25/2022 Item No.12.

DEALER SUPPLIED EOUIPMENT ANd/OT SERVICES
The following items andlor services will be provided by Golden State Fire Apparatus Inc. (GSFA) LICENSED MAI\UFACTURER
The State of California Vehicle Code, section I 1701 requires "every manufacturer of a vehicle subject to registration shall make application to the Department of Motor Vehicles (DMV) for a license containing a general distinguishing number". The manufacturer has a current license at time of proposal and shall provide a copy upon request. Temporary licenses are not acceptable.

LICENSED DEALERSHIP
The State of Califomia Vehicle Code, section 11701 requires a "dealer in vehicles of a type subject to registration, shall make application to the Department of Motor Vehicles (DMV) for a license containing a general distinguishing number". Golden State Fire Apparatus, Inc. has a current license at time of bid as outlined above and is available upon request. Temporary licenses are not acceptable.

LICENSED SALES REPRESENTATIVE
The State of California Vehicle Code, section 1 1800 requires that it shall be "unlawful for any person to function as a vehicle salesperson without having first procured a license issued by the Department of Motor Vehicles (DMV)". The representative has a current vehicle salespersons license at time of proposal and shall provide a copy upon request. Temporary licenses are not acceptable.

VEHICLE REGISTRATION
The State of California Vehicle Code section 11739 requires that the "dealer of a new motor vehicle sale is responsible for applying for the title, securing vehicle registration, and obtaining license plates for the Customer" through the Department of Motor Vehicles (DMV). Golden State Fire Apparatus, Inc. is a factory-authorized dealer of the vehicle being sold and is authorized to register with the State of California as a new vehicle manufacturer.

GSFA will make all necessary applications and complete all transfer papers, including applying for California Exempt "E" license plates.

LOOSE EOUIPMENT
The following loose equipment list will be provided by Golden State Fire Apparatus Inc. prior to final Motorola Solution Quote 1849030 (EXPIRES 11-13-22\ 1
Vincent Communications BK Quote # 52023 1
2112" x 50' Hose Key Big 10 (FDNY spec) Orange DP25-800 50 FT 8 2 1 12" x 25' Hose Key Big 10 (FDNY Spec) P25-800 1
41 314" x 50' Hose Key Big 10 (FDNY spec) Blue DP18-800-FDNY I 1 12" x 100' single jacket wildland hose Key SP-15-600 PU 12 1 1 12" x 15' Hose, Angus Rubber Jacket, RED Reg Duraflow RC15-600 2 81" x 100' NPSH sinqle iacket wildland hose KEY SP10-600 PU 3/4" x 100'NPSH live reel hose (rubber) Kocheck KRBH75-100-3 3/4" x 50' NPSH live reel hose (rubber) Kocheck KRBH75-50-3 103/4" x 50 feet pencil line hose Key FF075-600
4" x 7' Hard suction hose with rocker luos Kocheck 2PW0210 2 4" Hard Suction Strainer Kocheck BS40 I
2 2

Page 151 ends

10/25/2022 Item No.12.
1 1 12" x Z Hard suction hose Kocheck PF152-1O 2
11 1/2" Floating Strainer self leveling with foot valve Kocheck #FS15FV 1 1 /2" Stainer with foot valve Kocheck KC-8S151 1
1 314" Nozzle 1 50 GPM/75PS| Elkhart Chief XD mid-range with 15/1 6" smoothbore with quantity (2) 7/8" smoothbore nozzles that go with the Chief XD 2
1 ll2" Nozzle 20-95 GPM @ 100 psiTask Force Tip FS2095 6 3l" Nozzle 10-24 GPM Task Force Tip DS1024 with bale and pistol grip 101" Wildland twister nozzles
3/4" Brass twister nozzles nozzles 10
12 1 12" double male Red Head #3625N25N
I2 1 12" double female Red Head #3525N25N
21 12" to 1 1 12" reducer Red Head #3725N15N 2
22112 to 1 112 galed wye NH Task Force Tip #AYNJNFTFT
11 1/2" double male Red Head #3615N15N
1 1 /2" double female Red Head #3515N15N 1
1 112" lo 1" NPSH reducerAction #3715N10P 3
21 1 /2" NH to 1" NPSH gated wye Mercedes #\ ru1510 (CS Supply) I 1/2" NH to 1" NPSH water thief / hose T TFT #ATNFID 4 41 112 Gizmo Pressure reduction appliance Gizmo#4702O
11" double male NPSH Action #3610P10P
1" double female NPSH Action #3510P10P 1
11" NPSH lo 1 112" increaserAction #3710P15N
21" to314" garden hose adapter NPSH Action #3710P75G
3/4" hose reel field reoair couplinq #BW1475BP 4
103/4" pencil line shut offs
2spanner wrench/hydrant wrench combo with (1) Red Head Mount pin lug spanners Red Head #103RH 2
Dead Blow Hammer Nupla SF-3SG I
1Forestry shovel - True temper
Pulaski - Council Tool Pulaski Axe FSS version 36" wood handle 2 2Thau Claw Fire Tool
16 ft New York Roof Hook Fire Hooks Unlimited #RH
30" Pro bar Fire Hooks Unlimited #PB-30 1
1Pick Head Axe Fire Axe lnc. 36" wood handle
1Flat Head Axe Fire Axe lnc. 36" wood handle
Pinch Point Bar 60" True Temper #1 160100 1
1Bolt cutters 36" with mounting hardware
1Come-a-long
2

Page 152 ends

10/25/2022 Item No.12.

IWildland Hose Packs with molle for clamp pouch, True North #3 with integrated clamp pouches 2Backpack pump - lndian Chief DBL500 backpack with Fedco pump 1 Collaosable Traffic Safetv Cone (Kit with 5 cones)
1Water Shut-off tool Reed Manufacturing #02347R (Acme Tools) 1Honda Portable Trash Pump WH20x 1 1/2 Discharge and 2" intake, no cage 1 Trash Pumo lntake adapter I 112" NPSH to NH
1 Trash Pump Discharge Adapter 1 1/2" NPSH to NH
1Chainsaw 18" Stihl MS261C
1Chainsaw 24" Stihl462C
1Honda Portable generator EU1000i
1htkit #AK-ELSS-XLAC-HGLED Flood LEDAkron
IPortable Fire Extinquisher 3A:408C with mountinq hardware 2Wheel Chocks Worden HWCTY-WH Hi Vis
2Drip torch with brackets Cascade Fire Equipment #12000 (Bracket #12001) 6Timberline hose clamos #FF-1
4Kholer Briqhtstar Riqht Anqle Rechargable Flashlight with 1 10 volt and DC charger 1Chainsaw mount-small Ziamatic QM-CSM-S
1 Chainsaw mount-laroe Ziamalic QM-CSM-L
2Fire-Line Tape
1hose rubbers or 4 lbs or QTY 20 HRRB ARC
1 GPS Reciever. Garmin Montana #010-01534-1 1
IBinauculars, Bushnell Marine 7x50 #137501
1 Kit #89088
1 EMS Pack Conterra Fliohtline Ultra Aero-Medical Pack
1 AED - ZOLL AED Plus
1 Ai Pro an
1 Hose Roller with 2" reciever mount
1 Tow Strap - vellow
1 3 fire20' rTow
1 Fuel Can for Drio torch fuel
Lock-out kit Access Tools Emergency Response Kit #ACT-ERK (Zips Towing) FINAL INSPECTION. FACTORY TRIP
A final inspection trip to the manufacturing facility will be provided for three (3) Customer representative(s). The intent ofthis trip is to ensure that the apparatus is built to specification and to detect any deficiencies that reiluire correction. The final inspection trip will have a duration of two (2) days and one (1) night and be scheduled at times mutually agreed upon between GSFA and the Customer. Costs for airfare, lodging, meals, and ground transportation while at the manufacturer's location will be the responsibility of GSFA. Air travel will be from one of the following airports: Sacramento, San Francisco, or San Jose.
-1

Page 153 ends

10/25/2022 Item No.12.

Costs such as Customer ground transportation in California, Customer airport parking, Customer luggage fees and Customer incidentals while traveling to the factory will be the responsibility of the Customer.

Flight reservations are non-refundable and in the event of a cancellation after booking, the Customer will be responsible for all costs associated with this cancellation, which may include not only the original ticket cost but also any change or cancellation fees imposed by the airline and/ or travel agency. Flight reservations are also non-transferable.

DELIVERY TO AUTHORIZED SERVICE FACILITY
GSFA will, at their expense, deliver the apparatus (including any applicable equipment, spare parts, and supplies) to their Northern Califomia facility in Sacramento for a dealer preparation inspection.

To ensure proper break in of all components while still under warranty, the apparatus shall be delivered under its own power - rail or truck freight shall not be acceptable.

PRE-DELIVERY SERVICE
After transportation from the factory and prior to delivery, the apparatus will receive a pre-delivery service to confirm proper operation and correction ofany issues found as a result ofsaid inspection. The Golden State Fire Apparatus, Inc. pre-delivery service consists of the following:

Engine Compartment and Undercarriage - Check for any broken mounting brackets and inspect for correct capacities of the following (if applicable): engine oil, coolant, power steering fluid, washer reservoir fluid, transmission fluid, rear end fluid, pump transmission oil, and primer oil. a
a
a
a
Interior - Operate all doors, windows, and locks for proper adjustment. Check upholstery.

Exterior - Repair reasonable paint scratches or chips. Tighten any loose hardware and inspect tires and wheels for proper pressure and lug torquing.

Road Test * With the water tank (if applicable) full, the apparatus will be driven approximately twenty miles which allows the drive train components to get up to operating temperature. Road test will be on both city and highway roads. A DOT compliant brake test will be conducted to ensure the system is holding air. The brake condition and wheel seals will also be inspected.

Electrical - Operate all lights, sirens, and other electrical accessories to verify operation.

Pump - If applicable, vacuum test the pump to hold for 15 minutes. After vacuum test, operate the relief valve, transfer valve and check pump shift. Check water tank for leaks and inspect water level gauge for calibration. With discharge caps loose, rapid test all individual gauges and main gauges for calibration. Lubricate valve rods.

Foam System - If applicable, tighten caps and connect foam lines. Test selector, valves, metering valve and operation of foam system (including flush).

Fuel Tank - Fuel tank will be filled at the dealership location prior to final delivery.

DEF Tank - DEF tank will be filled at the dealership location prior to final delivery.

Wash - The apparatus will be thoroughly washed at the dealership location prior to final delivery. a
a
a
a
a
a
4

Page 154 ends
← All documents from this meeting