Cities Index.
Agenda packet

Gilroy City Council
June 29, 2026

Document
Agenda packet
Meeting
June 29, 2026
Body
Gilroy City Council
Pages
256
Original file
67.6 MB
Text extracted from the city's file for reading and search. Open the original on gilroyca.api.civicclerk.com. That file is the official record.

Revision Date
408-780-7200 Office 60 South Market Street, Suite 1250 San Jose, California 95113

NOT FOR REGULATORY APPROVAL,

PERMITTING OR CONSTRUCTION

ARCHITECTURE ENGINEERING INTERIOR DESIGN

LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
Developed for
Checked ByScaleJob Number
Submittal Date
70% SCHEMATIC DESIGN 03/10/2026
100% SD / BRIDGING DOCS 03/26/2026
This document and all other project documents, ideas, aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.Project documents describe the design intent of the work and are not a representation of as-built or existing conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions.© LPA, Inc.

SANTA TERESA FIRE STATION
1330 W EST LUCHESSA AVENUE
GILROY, CA 95020
GRIFFIN STRUCTURES, INC.

PLUMBING SCHEDULES
P6.00
33236Checker

PLUMBING FIXTURE SCHEDULE

ITEM FIXTURE TYPE GPM/GPF
ROUGH-IN CONNECTION SIZES (in)

MOUNT HARDWARE TYPE DESCRIPTION WASTE VENT COLD WATER HOT WATER ASWF-1 ANTI-SCALE WATER FILTRATION 60 0" 0" 2" 0" FLOOR MOUNT WATTS ONEFLOW ANTI-SCALE WATER FILTRATION SYSTEM (OR SIMILAR). 60 GPM CAPACITY. INSTALL PER MANUFACTURERS REQUIREMENTS.

BF-1 BOTTLE FILLER, RECESSED 2" 1 1/2" 3/4" WALL MOUNT FILTERED BOTTLE FILLING STATION, REFRIGERATED, STAINLESS COTG CLEANOUT TO GRADE 4" FLOOR MOUNT ADJUSTABLE FLOOR CLEANOUT, DURA-COATED CAST IRON BODY, WITH GAS AND WATER TIGHT ABS TAPERED THREAD PLUG AND ROUND SCORIATED CAST IRON EXTRA-HEAVY-DUTY SECURED TOP ADJUSTABLE TO FINISHED FLOOR.

CWB-1

CLOTHESWASHER

SUPPLY AND DRAIN

BOX, FIRE RATED
"FIRE RATED WMOB W/ 1/2" SWEAT/ QTR/ ARRESTER", RECESSED WALL MOUNT TYPE, 1/4 TURN VALVES W/ WATER HAMMER ARRESTERS MOUNTED IN HEAVY DUCT

STEEL ENCLOSURE W/ WHITE POWDER COAT FINISH & TWO FACTORY INSTALLED INTUMESCENT PADS, ONE OR TWO HOUR RATED DEPENDING ON WALL CONSTRUCTION. INSTALL IN ACCORDANCE WITH THE MFR'S RECOMMENDATIONS.

DSB-1 DOWNSPOUT BOOT WALL MOUNT ENAMELED CAST IRON DOWNSPOUT BOOT WITH WALL SECURING CLAMP AND CLEANOUT PORT.

ET-1 THERMAL EXPANSION TANK 3/4" WALL MOUNT DIAPHRAGM TYPE, WELDED HIGH GRADE STEEL SHELL WITH EXTERIOR COATING, SHRADER VALVE W/ ADJUSTABLE AIR PRECHARGE, AND LEAD FREE SYSTEM CONNECTION. COMPLETE W/ MAPA PRODUCTS EXPANSION TANK CAGE SIZED FOR EXPANSION TANK.

FCO FLOOR CLEANOUT 4" FLOOR MOUNT ADJUSTABLE LEVELING FLOOR CLEANOUT, DURA-COATED CAST IRON BODY WITH GAS & WATER TIGHT ABS TAPERED THREAD PLUG, AND ROUND, SCORIATED SECURED LIGHT-DUTY TOP WITH ADDITIONAL LEVELING ADJUSTMENT TO FINSIHED FLOOR.

FD-1 FLOOR DRAIN, SQUARE STRAINER 2" 1 1/2" FLOOR MOUNT LAQUERED CAST IRON DRAIN BODY W/ ANCHOR FLANGE, CAST IRON MEMEBRANE CLAMP RING W/ PRIMARY & SECONDARY WEEP HOLES, 5" SQUARE STAINLESS STEEL STRAINER, 1/2" TRAP SEAL PRIMER CONNECTION FD-2

FLOOR DRAIN,

SHOWER, ROUND

STRAINER
2" 1 1/2" FLOOR MOUNT LAQUERED CAST IRON DRAIN BODY W/ ANCHOR FLANGE, CAST IRON MEMEBRANE CLAMP RING W/ PRIMARY & SECONDARY WEEP HOLES, 5" ROUND STAINLESS STEEL STRAINER, 1/2" TRAP SEAL PRIMER CONNECTION FS-1 FLOOR SINK 2" 1 1/2" FLOOR MOUNT FLOOR SINK, 12" X 12" X 8" DEEP CAST IRON FLOOR AREA & INDIRECT SANITARY WASTE DRAIN, WHITE ACID RESISTANT COATED INTERIOR, LOOSE SET ACID RESISTANT COATED GRATE WITH ALUMINUM DOME BOTTOM STRAINER, FLASHING CLAMP WITH 1/2 GRATE WITH HARDWARE. HB-1 HOSE BIBB 3/4" ROOF MOUNT ROOF HOSE BIBB HB-2 HOSE BIBB 0" 0" 3/4" 0" WALL MOUNT FOX DEMAND VALVE HOSE BIBB FOR FOX DRAIN HR-1 HOSE REEL WALL MOUNT STATIC DISCHARGE REEL, 50', SINGLE LEAD, YELLOW. ATTACH TO WALL AT MINIMUM 9'-0" AFF.

IMB-1 ICEMAKER SUPLY BOX, FIRE RATED 3/4" WALL MOUNT "WHITE POWER COATED METAL IMOB 1/4 TURN VALVE - 1/2" SWEAT CONX", CALIF. AB 1953 COMPLIANT, RECESSED WALL TYPE, 1/4 TURN VALVE & MOUNTED IN HEAVY DUYT STEEL ENCLOSURE W/ WHITE POWDER COAT FINISH & TWO FACTORY INSTALLED INTUMESCENT PADS, ONE OR TWO HOUR RATED DEPENDING ON WALL CONSTRUCTION. INSTALL IN ACCORDANCE WITH MFR'S RECOMMENDATIONS.

L-1 LAVATORY, ADA .5 2" 1 1/2" 3/4" 3/4" UNDERMOUNT MANUAL FAUCET LAVATORY - VITREOUS CHINA, PREWRAPPED TRAP SUPPLY COVERS, LOOSE KEY STOPS, AND RIGID SUPPLIES, ADA OI-1 SAND OIL INTERCEPTOR 4" 3" UNDERMOUNT SAND OIL INTERCEPTOR. TRAFFIC RATED WITH SAMPLE BOX.

RD/OD ROOF & OVERFLOW DRAINS ROOF MOUNT 15" DIAMETER COMBINATION MAIN ROOF AND OVERFLOW DRAIN WITH LOW SILHOUETTE CAST IRON DOMES AND DOUBLE TOP SET DECK PLATE AND VANDAL PROOF SECURED TOP.

RHB-1 RECESSED HOSE BIBB 3/4" WALL MOUNT STAINLESS STEEL RECESSED HOSE BOX WITH WALL FLANGE.

RPBF-1

REDUCING

PRESSURE

BACKFLOW

PREVENTER
LEAD-FREE DOUBLE CHECK VALVE "A SERIES", TOP ACCESS MODULAR CHECK VALVE CARTRIDGES, PROVIDE CAPTURED SPRINGS, REPLACEABLE SEATS ANDREVERSIBLE SILICONE SEAT DISCS, BALL VALVE SHUT-OFF'S WITH STAINLESS STEEL HANDLES & NUTS.

S-1

SINGLE COMP SINK,

STAINLESS STEEL,
ADA

1.5 2" 1 1/2" 3/4" 3/4" UNDERMOUNT MANUAL FAUCET
ADA COMPLIANT SINGLE COMPARTMENT UNDERMOUNT SINK, 18 GAUGE TYPE 304 STAINLESS STEEL, DECK MOUNTED FAUCET, INSINKERATOR "BADGER 1" GARBAGE DISPOSAL, BRASS BASKET STRAINER, P-TRAP WITH PRE-WRAPPED TRAP AND SUPPLY COVERS, GALVANIZED NIPPLE TRAP ARM W/ CHROMIUM PLATED BRASSCASING, & LOOSE KEY STOPS WITH RIGID SUPPLIES. INSTALL IN ACCORDANCE WITH ADA ACCESSIBILITY REQUIREMENTS.

SH-1 SHOWER SYSTEM 1.8 3/4" 3/4" WALL MOUNT SHOWER SYSTEM, PRESSURE BALANCING MIXING VALVE WITH LEVER HANDLE & ADJUSTABLE STOP SCREW, INTEGRATED VOLUME CONTROL SHOWERHEAD, POLISHED CHROME FINISH, AND INTEGRAL SERVICE STOPS AND REVERSE SEAT WHERE REQUIRED.SH-2 SHOWER SYSTEM, ADA 1.8 3/4" 3/4" WALL MOUNT SHOWER/HAND SHOWER SYSTEM, PRESSURE BALANCING MIXING VALVE WITH HAND SPRAY, 5'-0" FLEXIBLE METAL HOSE, IN-LINE VACUUM BREAKER, DIVERTER VALVE WITH HANDLE, 36" SLIDE BAR AND INTEGRAL SERVICE STOPS. INSTALL IN ACCORDANCE WITH ADA ACCESSIBILITY REQUIREMENTS.SH-3 SHOWER SYSTEM 1.8 3/4" 3/4" WALL MOUNT SHOWER SYSTEM, PRESSURE BALANCING MIXING VALVE WITH LEVER HANDLE & ADJUSTABLE STOP SCREW, INTEGRATED VOLUME CONTROL SHOWERHEAD, POLISHED CHROME FINISH, AND INTEGRAL SERVICE STOPS AND REVERSE SEAT WHERE REQUIRED.

SS-1 SERVICE SINK 3" 2" 3/4" 3/4" MANUAL FAUCET FABRICATED NSF SINK, 1-COMPARTMENT, BOWL SIZE 18" X 18" X 18" DEEPSS-2 2-COMPARTMENT SINK 3" 2" 3/4" 3/4" MANUAL FAUCET FABRICATED NSF SINK, 2-COMPARTMENT, 18" RIGHT & LEFT DRAINBOARDS, BOWL SIZE 18" X 18" X 18" DEEPTD-1

TRENCH DRAIN,

TRAFFIC WEIGHT

STRAINER
4" 2" FLOOR MOUNT
6" WIDE PRE-SLOPED TRENCH DRAIN SYSTEM, POLYPROPYLENE DRAIN BODY W/ INTEGRAL TOP FRAME AND 1/4" PER SECTION BOTTOM SLOPE, ANCHOR FLANGE W/SLOTTED TABS EVERY 10" FOR REBAR TIE-DOWN AND LEVELING, GRATE LOCKDOWN ASSEMBLY, BODY SUPPORT LEGS, INTERLOCKING ENDS, AND RADIUSEDBOTTOM. STANDARD W/ ANSI RATED SPECIAL DUTY LAQUERED DUCTILE IRON HEEL PROOF GRATES W/ SAFE LIVE LOAD OF OVER 10,000 LBS. ITEM SIZE SHALLCORRESPOND TO FULL LINE SIZE OF PIPING SERVED. SEE PLANS FOR SIZES.

TD-2 TRENCH DRAIN 3" 2" FLOOR MOUNT LINT TRAP
6" WIDE PRE-SLOPED TRENCH DRAIN SYSTEM, POLYPROPYLENE DRAIN BODY W/ INTEGRAL TOP FRAME AND 1/4" PER SECTION BOTTOM SLOPE, ANCHOR FLANGE W/ SLOTTED TABS EVERY 8" FOR REBAR TIE-DOWN AND LEVELING, GRATE LOCKDOWN ASSEMBLY, BODY SUPPORT LEGS, INTERLOCKING ENDS, AND RADIUSED BOTTOM.STANDARD W/ ANSI RATED SPECIAL DUTY LAQUERED DUCTILE IRON HEEL PROOF GRATES TMV-1 THERMOSTATIC MIXING VALVE 3/4" 3/4" WALL MOUNT POINT OF USE THERMOSTATIC MIXING VALVE WITH INTEGRAL CHECK VALVES ON HOT AND COLD INLETS, 1/2" INLETS & 1/2" OUTLET, 0.25 GPM MIN FLOW CAPACITY, 12 GPM MAX FLOW CAPACITY. INSTALL WITH SHUT OFF VALVES AND WALL MOUNTING BRACKET. SET OUTPUT TEMPERATURE TO 105 DEGREES.

TP-1 TRAP PRIMER, SINGLE DRAIN 3/4" WALL MOUNT 1/2" MALE NPT INLET AND 1/2" FEMALE NPT OUTLET & REMOVABLE FILTER SCREEN. INSTALL COMPLETE W/ WALL ACCESS PANEL, SHUT-OFF VALVE, & 1/2" TYPE "L" COPPER DRAIN LINE FROM TRAP SEAL PRIMER OUTLET TO RECEPTOR CONNECTION POINT.

WC-1 WATERCLOSET, ADA 1.28 4" 2" 1" FLOOR MOUNT MANUAL FLUSH VALVE WATER CLOSET, SIPHON JET ACTION, ELONGATED BOWL, WHITE VITREOUS CHINA, COMPLETE W/ MANUAL FLUSHOMETER VALVE, & OLSONITE MODEL No. 95SSCT "STA-TITE" (AS MANUFACTURED BY BEMIS) WHITE ELONGATED OPEN FRONT SEAT LESS COVER W/ STAINLESS STEEL CHECK HINGE.

WCO WALL CLEANOUT WALL MOUNT WALL CLEANOUT, DURA-COATED CAST IRON BODY WITH GAS & WATER TIGHT ABS TAPERED THREAD PLUG, AND ROUND, SMOOTH STAINLESS STEEL ACCESS COVER WITH SECURING SCREW.

WHA-1 WATER HAMMER ARRESTOR 3/4" WALL MOUNT PISTON WATER HAMMER ARRESTOR, HARD DRAWN SEAMLESS TYPE "K" COPPER BODY, BRASS MALE NPT CONNECTION. INSTALL COMPLETE W/ WALL ACCESS PANEL. WATER HAMMER ARRESTORS SHALL BE SIZED IN ACCORDANCE W/ MFR'S SIZING CRITERIA PER FIXTURE UNIT CAPACITY SERVED AT EACH LOCATION/OCCURRANCE.

WS-1 WATER SPIGOT 3/4" COUNTER MOUNT FILTRATION UNIT STAINLESS STEEL WATER FAUCET. CONNECT PENTAIR "EVERPURE SERIES DRINKING WATER FILTRATION.

CIRCULATING PUMP SCHEDULE
ITEM MANUFACTURER MODEL NO. LOCATION TYPE CAPACITY ELECTRICAL OPERATING WEIGHT (LBS) DESCRIPTION GPM HEAD VOLTAGE AMPS PHASE kW HP RPM CP-1 GRUNDFOS UP 15-42 B5 LAUNDRY/JANITOR 108 11.1 14.4 115 V 1 A .114

ELECTRIC WATER HEATER SCHEDULE
ITEM MANUFACTURER MODEL NO. LOCATION STORAGE CAPACITY (GAL.) INCOMING CW TEMP (DEG. F.) OUTGOING HW TEMP (DEG. F.) TEMP RISE (DEG. F.) RECOVERY (GAL/HR) OPERATING WEIGHT (LBS) ELECTRICAL DESCRIPTION VOLTAGE AMPS PHASE kW EWH-1 AO SMITH DRE-120 LAUNDRY/JANITOR 108 120 140 154 208 V 83.3 A 3 30

ELECTRIC TRAP PRIMER SCHEDULE
ITEM LOCATION INLET SIZE ELECTRICAL EQUIPMENT SIZE DESCRIPTION VOLTAGE AMPS PHASE kW ETP-1 FIRE RISER 129 3/4" MINI-PRIME ELECTRONIC FLOOR DRAIN TRAP PRIMER WITH NEMA 1 BOX, 115VETP-2 APPARATUS BAY 125 3/4" MINI-PRIME ELECTRONIC FLOOR DRAIN TRAP PRIMER WITH NEMA 1 BOX, 115VETP-3 APPARATUS BAY 125 3/4" MINI-PRIME ELECTRONIC FLOOR DRAIN TRAP PRIMER WITH NEMA 1 BOX, 115VETP-4 TRASH ENCLOSURE 3/4" MINI-PRIME ELECTRONIC FLOOR DRAIN TRAP PRIMER WITH NEMA 1 BOX, 115V NOTES:1. ALL BRAZED AND SOLDERED JOINTS SHALL BE LEAD FREE. EXPOSED VENT PIPE SHALL BE GALVANIZED PER SPECIFICATIONS.2. ALL METALLIC PIPING BELOW GRADE SHALL BE ENCASED WITH 10 MIL MINIMUM POLYETHYLENE PLASTIC SLEEVE. ALL FITTINGS, VALVES, ETC. THAT ARE NOT ABLE TO BE ENCASED WITHIN SLEEVESHALL PROVIDE HEAVY OF "HENRY'S" OIL BASE ROOF MASTIC OVER ENTIRE SURFACE AND WRAPPED ENTIRE COMPONENT BY 10 MIL FERGUSON POLYETHYLENE WRAP WITH OVERLAPPED 50% OF THE CIRCUMFERENCE. SECURE ENDS AND SEAMS BY 3M SCOTCH, 10 MIL, 2" WIDE PIPE WRAP SEALING TAPE. INSTALL PER MANUFACTURER'S RECOMMENDATIONS.

BELOW GRADE OUTSIDE WITHIN FIVE FEET (5') OF THE FOUNDATION SHALL BE PVC PIPE APPROVED FOR FIRE SERVICE CLASS 150 (DR-18) WITH CAST IRON, RING-TITE FITTINGS AS REQUIRED.

FIRE PROTECTION
ABOVE GRADE DUCTILE IRON, CEMENT LINED WITH MECHANICAL JOINT FITTINGS, CLASS 250, FLANGED OR MECHANICAL JOINT, IN ACCORDANCE WITH ANSI-AWWA C111/A21.11, CLASS 52 OR AWWA C153 DUCTILE IRON COMPACT FITTINGS.

BELOW GRADE SAME AS ABOVE WITH HEAVY-DUTY 4-BAND SHIELDED COUPLINGS ENCASED WITHIN A MINIMUM OF 10 MIL POLYETHYLENE PLASTIC SLEEVE SEALED WATER TIGHT WITH POLYVINYL CHLORIDE TAPE. SANITARY VENT ABOVE GRADE HUBLESS CAST IRON PIPE AND FITTINGS, ASTM A 888 OR CISPI 301, SHIELDED COUPLINGS ASTM C 1277, STANDARD-DUTY, 2-BAND SHIELDED, STAINLESS-STEEL COUPLINGS AND ASTM C 564 RUBBER SLEEVE.

BELOW GRADE SAME AS ABOVE ENCASED WITHIN A MINIMUM OF 10 MIL POLYETHYLENE PLASTIC SLEEVE SEALED WATER TIGHT WITH POLYVINYL CHLORIDE TAPE.

SANITARY WASTE
ABOVE GRADE HUBLESS CAST IRON PIPE AND FITTINGS, ASTM A 888 OR CISPI 301, SHIELDED COUPLINGS ASTM C 1540, HEAVY-DUTY, 4-BAND SHIELDED, STAINLESS-STEEL COUPLINGS AND ASTM C 564 RUBBER SLEEVE.

BELOW GRADE SAME AS ABOVE ENCASED WITHIN A MINIMUM OF 10 MIL POLYETHYLENE PLASTIC SLEEVE SEALED WATER TIGHT WITH POLYVINYL CHLORIDE TAPE.

STORM / OVERFLOW
DRAIN
ABOVE GRADE HUBLESS CAST IRON PIPE AND FITTINGS, ASTM A 888 OR CISPI 301, SHIELDED COUPLINGS ASTM C 1540, HEAVY-DUTY, 4-BAND SHIELDED, STAINLESS-STEEL COUPLINGS AND ASTM C 564 RUBBER SLEEVE.

WITHIN BUILDING SAME AS ABOVE EXCEPT WITH 1-INCH THICK FLEXIBLE ELASTOMERIC, COMPLYING WITH ASTM C534/C534M GRADE 1; USE TUBULAR MATERIAL WHEREVER POSSIBLE. CONDENSATE DRAIN ON ROOF HARD DRAWN COPPER DWV TUBE, ASTM B 306, DRAINAGE TUBE, DRAWN TEMPER. COPPER DRAINAGE DWV FITTINGS, ASME B16.23, CAST COPPER OR ASME B16.29, WROUGHT COPPER, SOLDER-JOINT FITTINGS.

HOT WATER
SAME AS COLD WATER ABOVE COMPLETE WITH 1" THICK ONE-PIECE PRE-FORMED GLASS FIBER MOLDED PIPE INSULATION WITH ALL PURPOSE FIRERETARDANT VAPOR BARRIER JACKET FOR 3/4" DIAMETER PIPES AND SMALLER, 1-1/2" THICK INSULATION FOR 1" TO 1-1/2" DIAMETER PIPES AND 2" THICKINSULATION FOR 2" DIAMETER PIPES AND LARGER. (VIEGA PRO PRESS FITTINGS ARE AN ACCEPTABLE SUBSTITUTION FOR SOLDER JOINTS).

BELOW GRADE
SOFT COPPER TUBE, ASTM B88, TYPE K WATER TUBE, ANNEALED TEMPER. COPPER SOLDER-JOINT FITTINGS, ASME B16.22, WROUGHT-COPPERPRESSURE FITTINGS. ENCASE WITHIN A HIGH DENSITY CROSS LAMINATED POLYETHYLENE FILM, MINIMUM 10 MIL THICK, TUBE FORM, ASTM A674 OR AWWA C105, FOR PROTECTION AGAINST CORROSION. DOMESTIC WATER COLD WATER HARD COPPER TUBE, ASTM B88, TYPE L WATER TUBE, DRAWN TEMPER. WROUGHT-COPPER SOLDER-JOINT FITTINGS (VIEGA PRESS FITTINGS ARE AN ACCEPTABLE SUBSTITUTION FOR SOLDER JOINTS), ASME B16.22, WROUGHT-COPPER PRESSURE FITTINGS.

SERVICES LOCATION MATERIAL

PIPE MATERIALS SCHEDULE
QD-1 AMFLO CP9 & CP10 QUICK DISCONNECT AMFLO MODEL NO. C10 COUPLER AND CP9 COUPLER AND PLUG. 1/2" FEMALE NPT, PLATED STEEL COUPLER AND PLUG. WORKING PRESSURE AT 300 P.S.I. MAXIMUM. FURNISH WITH ESCUTCHEON.

OWS-1 QUINCY QCS 100 AIR COMPRESSOR OIL/WATER... QUINCY SERIES 100, OIL/WATER SEPARATOR, WITH 1/2" INLET, 45 - 90 SCFM CAPACITY, 7.9 x 7.9 x 20.7 INCHES, WEIGHT = 7.7 LBS.

FB-1 QUINCY QMF 50 AIR COMPRESSOR PRE-FILTER QUINCY QMF 50 SERIES COMPRESSED AIR PRE-FILTER, 50 CFM FLOW CAPACITY. 100 PSIG OPERATING PRESSURE. AIR CONNECTION IN / OUT AT 1/2" NPT THREAD. PROVIDE WITH 1/4 INCH DRAIN TO APPROVED RECEPTOR. 2.8 x 2.8 x 9.1 INCHES, ISO 8573 COMPLIANT, OPERATING WEIGHT: 1.3 LBS.

AD-1 QUINCY QPNC-21 AIR COMPRESSOR DRYER
QUINCY QPNC-21, COMPRESSED AIR DRYER. MAXIMUM OVER-ALL DIMENSIONS SHALL BE 13.97 HIGH X 13.78 WIDE X 19.42 LONG. THE COMPLETE UNIT SHALL BE BOLTED TO THEFLOOR AND PROVIDED WITH SEISMIC BRACES WHERE REQUIRED. THE UNIT SHALL DELIVER 15 CFM AT 41°F PRESSURE DEW POINT AT 189°F MAXIMUM PRESSURE. AIRCONNECTION IN / OUT AT 1/2" NPT THREAD. UNIT SHALL BE 120 VOLTS, 1 PHASE, 2.7 AMPS, 60 HZ. OPERATING WEIGHT: 57 LBS.

AC-1 QUINCY QT-5 AIR COMPRESSOR EQUIPMENT
SPLASH LUBRICATED, TWO-STAGE CAST IRON PISTON AIR COMPRESSOR. MAXIMUM OVER-ALL DIMENSIONS SHALL BE 74" HIGH X 24" WIDE X 37" LONG. THE COMPLETE UNITSHALL BE BOLTED TO THE FLOOR AND PROVIDED WITH SEISMIC BRACES. AIR COMPRESSOR: 5 H.P., 208 VOLTS, 3 PHASE, 1800 RPM, 60 HZ. COMPRESSOR SHALL DELIVER 17.2 CFM AT 100 PSI AT 175 P.S.I. MAXIMUM OPERATING PRESSURE. TANK SHALL BE OF 80 GALLON CAPACITY, VERTICAL TYPE. THE UNIT SHALL BE PROVIDED WITH THE FOLLOWING ACCESSORIES: WIRE BELT GUARD, SAFETY VALVE, AIR VALVE, AIR OUTLET VALVE, PRESSURE GAUGE, ELECTRONIC DRAIN TRAP AND PRESSURE SWITCH, LOW OIL SWITCH ANDAFTER COOLER. APPROXIMATE OPERATING WEIGHT: 680 LBS. TAG MFR. MODEL NO. FIXTURE TYPE DESCRIPTION

AIR COMPRESSOR SCHEDULE

Page 247 of 256 ends

ABBREVIATIONS
4S/DP
ACT
ADA
AFF
AFG
AWG
AMP, A
AIC
AF/AT
AHJ
AS/AF
ATS
AVG
4" SQUARE BY 2 1/8" DEEP BOX

ACOUSTICAL CEILING TILE

AMERICAN WITH DISABILITIES ACT

ABOVE FINISH FLOOR

ABOVE FINISH GRADE

AMERICAN WIRE GAUGE
AMPERE

AMPERES INTERRUPTING CAPACITY (SYMMETRICAL)

AMP FRAME, AMP TRIP

AUTHORITY HAVING JURISDICTION

AMP SWITCH, AMP FUSE

AUTOMATIC TRANSFER SWITCH

AVERAGE
BDF
BR
BLDG

BUILDING DISTRIBUTION FRAME
BRANCH

BUILDING
CEC
CIRC., CKT
CB
CSFD C
CO
CONN
CPT
CLCB
CLF
CT

CALIFORNIA ELECTRICAL CODE

CIRCUIT

CIRCUIT BREAKER

COMBINATION SMOKE FIRE DAMPER

CONDUIT

CONDUIT ONLY, COMPLETE WITH PULLSTRING

CONNECTED

CONTROL POWER TRANSFORMER

CURRENT LIMITING CIRCUIT BREAKER

CURRENT LIMITING FUSE

CURRENT TRANSFORMER
(D)
DIA
DISC
DIST

EXISTING TO BE DEMOLISHED

DIAMETER

DISCONNECT

DISTRIBUTION
EC
EMS
EMT
ENT
EWC
EPO
E-O-L
EF
E/G
EP
(E)
(ER*)

ELECTRICAL CONTRACTOR

ENERGY MANAGEMENT CONTROL SYSTEM

ELECTRICAL METALLIC TUBING

ELECTRICAL NON-METALLIC TUBING

ELECTRIC WATER COLLER

EMERGENCY POWER OFF

END-OF-LINE CIRCUIT TERMINATOR

EXHAUST FAN

EQUIPMENT GROUND (GREEN)

EXPLOSION PROOF

EXISTING EQUIP TO REMAIN
EXISTING EQUIP TO BE RELOCATED (*CORRESPONDS TO

NEW LOCATION)
FT or '
FA
FLA
FEET

FIRE ALARM

FULL LOAD AMPS
GRD
GFCI
GFP
GEC
GROUND

GROUND FAULT CIRCUIT INTERRUPTER

GROUND FAULT PROTECTION

GROUNDING ELECTRODE CONDUCTOR
HACR
HOA
HVAC

H, W, D, L
HID
HP
HPS

HEATING AIR CONDITIONING REFRIGERATION

HAND-OFF-AUTO

HEATING, VENTILATING AND AIR CONDITIONING

HEIGHT, WIDTH, DEPTH, LENGTH

HIGH INTENSITY DISCHARGE

HORSEPOWER

HIGH PRESSURE SODIUM
IN or "
I/G
IDF
INCHES

OSOLATED GROUND

INTERMEDIATE DISTRIBUTION FRAME

JBOX JUNCTION BOX K
KCMIL
KVA
KW
KWH

DEGREE KELVIN

THOUSAND CIRCULAR MILS

KILOVOLT AMPERES

KILOWATT

KILOWATT HOUR
LCL
LF

LTG, LTS
LPS

LONG CONTINUOUS LOAD

LINEAR FEET

LIGHTING

LOW PRESSURE SODIUM
MAX
MDF
MOCP
MCB
MLO
MCM
M/M
MV
MH
MIN
MCA
MCC
MCM
MCP
MFR
MTD
MW

MAXIMUM

MAIN DISTRIBUTION FRAME

MAXIMUM OVERCURRENT PROTECTION

MAIN CIRCUIT BREAKER

MAIN LUGS ONLY

MECHANICAL CONTRACTOR
METER

METER MAIN

MERCURY VAPOR

METAL HALIDE

MINIMUM

MINIMUM CIRCUIT AMPS

MOTOR CONTROL CENTER

THOUSAND CIRCULAR MILS

MOTOR CIRCUIT PROTECTOR

MANUFACTURER

MOUNTED

MICROWAVE
(N)
NATS
NEC
NEMA
NC
NO
NF
NIC
NTS
NL
NO or #
NEW

NON AUTOMATIC DISCONNECT

NATIONAL ELECTRICAL CODE

NATIONAL ELECTRICAL MANUFACTURERS' ASSOCIATION

NORMALLY CLOSED

NORMALLY OPENED

NON-FUSED

NOT IN CONTRACT

NOT TO SCALE

NIGHT LIGHT
NUMBER

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
%Z
PH or ~
PC
PCP
PVC
PDU

PRIMARY

PROVIDE
PT
PA

PERCENT IMPEDANCE
PHASE

PHOTOCELL

PLUMBING CONTRACTOR
POWER

POLY VINYL CHLORIDE

POWER DISTRIBUTION UNIT
OVER 600 VOLTS

FURNISH, INSTALL AND CONNECT

POTENTIAL TRANSFORMER

PUBLIC ADDRESS
RE

REC, RECEPT
REF
RGS
RMS

REPLACE EXISTING (IN-PLACE)

RECEPTACLE

REFRIGERATOR

RIGID GALVANIZED STEEL

ROOT MEAN SQUARE
SCC
SCS
SFD

SECONDARY
SMACNA
SPD
SQ

SHORT CIRCUIT CURRENT

STRUCTURED CABLING SYSTEM

SMOKE FIRE DAMPER
600 VOLTS AND LESS
SHEET MTL & AIR COND. CONTRACTORS' NATIONAL ASSOC.

SURGE PROTECTION DEVICE
SQUARE
TC

TEL/DATA
TV
TVSS
TYP

TIMECLOCK

TELEPHONE AND DATA

TELEVISION

TRANSIENT VOLTAGE SURGE SUPPRESSION

TYPICAL
UGPS
UNO
UPS

UNDERGROUND PULL SECTION

UNLESS OTHERWISE NOTED

UNINTERRUPTABLE POWER SYSTEM
VAVV
VA
VD
VFD

VARIABLE AIR VOLUME
VOLTS

VOLT AMPERES

VOLTAGE DROP

VARIABLE FREQUENCY DRIVE

WPWWEATHERPROOF
WIRE
XFMR
XX

TRANSFORMER

EXISTING EQUIP TO BE DEMO'D

FLOOR BOX / SPECIALTY WALL BOX SYMBOLS
MECHANICAL EQUIPMENT CALLOUT, "AC" INDICATES UNIT TYPE & "2" INDICATES UNIT NUMBER. REFER TO MECHANICAL DWG FOR EXACT LOCATION & ELECTRICAL REQ.

ANNOTATIONS

TELEPHONE TERMINAL BACKBOARD SIZED AS NOTED, REFER TO

SYSTEM GROUND DETAIL

BRANCH CIRCUIT SYMBOLS
SINGLE SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE SPECIFICATIONS FOR MORE INFO.

TWO SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE SPECIFICATIONS FOR MORE INFO.

THREE SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE SPECIFICATIONS FOR MORE INFO.

FOUR SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN. SEE SPECIFICATIONS FOR MORE INFO.

SIX SERVICE IN FLOOR BOX. PROVIDE DEVICES PER PLAN.

SEE SPECIFICATIONS FOR MORE INFO.

DELTA CONFIGURATION
DETAIL CALLOUT, "3" INDICATES DETAIL NUMBER "E-1"
INDICATES SHEET NUMBER.

FEEDER SIZE DESIGNATION

LIGHTING FIXTURE DESIGNATION

KEYNOTE REFERENCE, REFER TO NOTES ON SHEETS, OR AS

DIRECTED

REVISION REFERENCE

WYE CONFIGURATION
GROUND

HOME RUN TO PANEL, LETTER DESIGNATES PANEL, NUMBERS

INDICATE CIRCUITS, PROVIDE DEDICATED NEUTRAL WIRE FOR
EA 'HOT' CIRCUIT IN CONDUIT RUN, #12 AWG MIN UNO
CONCEALED CONDUIT OR BRANCH CIRCUIT UNO, 1/2" CONDUIT
MIN, (2) #12 AWG CONDUCTORS MIN

CONCEALED CONDUIT OR BRANCH CIRCUIT ROUTED IN FLOOR
SLAB OR CONCRETE, COORDINATE INSTALLATION W/ DESIGNBUILD ENTITY & SUPPORT AS REQ 1/2" CONDUIT (2) #12 AWG

CONDUCTORS MIN
CONDUIT OR BRANCH CIRCUIT CONCEALED BELOW GRADE, 3/4"
CONDUIT MIN W/ (2) 12 AWG CONDUCTORS MIN & A CODE SIZED

EQUIPMENT GROUND
SURFACE-MTD CONDUIT OR BRANCH CIRCUIT UNO. 1/2" CONDUIT MIN, (2) #12 AWG CONDUCTORS MIN, CONDUIT SHALL BE PAINTED TO MATCH ADJ SURFACE. COORDINATE COLOR W/ ARCHITECT

INTERIORS

CONDUIT STUB OUT, CAP, MARK & RECORD ON AS-BUILT DWG

CONDUIT CONTINUATION
FLEXIBLE CONNECTION AS REQ. NUMBER OF CONDUCTORS AS REQ,

VERIFY CONNECTION REQ W/ MFR PRIOR TO ROUGH-IN

CONDUIT/ BRANCH CIRCUIT/FEEDER CONTINUATION DOWN WALL

TO FLOOR BELOW

CONDUIT/ BRANCH CIRCUIT/FEEDER CONTINUATION UP WALL TO

FLOOR ABOVE

EXG FEEDER, CONDUIT, WIRE TO BE DEMOLISHED

LOW VOLTAGE DUCTBANK BELOW GRADE
POWER DUCTBANK BELOW GRADE, SEE FEEDER TAG(s) FOR

QUANTITY & SIZE OF CONDUIT & WIRE

MEDIUM - HIGH VOLTAGE DUCTBANK BELOW GRADE, W/ VOLTAGE
INDICATED. SEE FEEDER TAG(s) FOR QTY & SIZE OF CONDUIT & WIRE

FLUSH MTD, LOCKABLE TERMINAL CABINET W/ TERMINAL STRIPS AS REQ

SURFACE MTD, LOCKABLE TERMINAL CABINET W/ TERMINAL

STRIPS AS REQ

XXX-XX X
X-X
XXXX1?
XXX
A-1,3,5
LV
X
X
P
12KV

LIGHTING SYMBOLS

DECORATIVE PENDANT

STRIP LIGHT (BOH)

DECORATIVE SURFACE MOUNTED LIGHT

SURFACE MOUNTED WRAP AROUND

RECESSED LENSED TROFFER

RECESSED ARCHITECTURAL TROFFER

RECESSED LINEAR OR PERIMETER WALL SLOT

PENDANT MOUNTED LINEAR

RECESSED LINEAR WALL WASH

RECESSED DOWN LIGHT

RECESSED WALL WASHER

RECESSED ADJUSTABLE ACCENT LIGHT

SURFACE MOUNTED DOWN LIGHT

WALL MOUNTED FIXTURE

TRACK LIGHT

SURFACE MOUNTED ADJUSTABLE LINEAR WALL WASHER

CONCEALED LINEAR LIGHT STRIP

RECESSED MULTI LAMP ADJUSTABLE DOWN LIGHT

WALL STEP LIGHT

BOLLARD LIGHT

ABOVE GRADE MOUNTED ADJUSTABLE ACCENT LIGHT

POLE MOUNTED LIGHT

EXIT SIGN

SURFACE MOUNTED EMERGENCY BATTERY PACK
"EM" SHADED OR HALF SHADED CONNECTION POINT

INDICATES FIXTURE ON EMERGENCY POWER

LIGHTING CONTROLS
•••••
WALL MTD OCCUPANCY SENSOR. MTG HEIGHT PER ADA - UNO
OR REQ. "xx" INDICATES THE FOLLOWING:

IO: INFRARED OCCUPANCY SENSOR
UO: ULTRASONIC OCCUPANCY SENSOR
DO: DUAL TECHNOLOGY OCCUPANCY SENSOR.

P: PHOTOCELL
OP: COMBINATION PHOTOCELL & DUAL TECHNOLOGY

OCCUPANCY SENSOR
LETTERS "ab" INDICATE ZONES CONTROLLED.

SINGLE POLE SWITCH, MTG HEIGHT PER ADA, SUBSCRIPT "K"
INDICATES KEY OPERATED SWITCH.

MANUAL ON/OFF, DIMMING & GRAPHIC SCENE SELECT CONTROL
STATION.

LOW VOLTAGE MANUAL ON/OFF, DIMMING & MULTI BUTTON
ZONE SELECT CONTROL STATION. "#" DENOTES NUMBER OF
ZONES. LETTERS "ab" INDICATE ZONES CONTROLLED.

WALL MTD COMBINATION VACANCY SENSOR & DIMMER SWITCH,
MTG HEIGHT PER ADA - UNO OR REQ. LETTERS "ab" INDICATES ZONES CONTROLLED. BOTH SWITCH LEGS TO BE CONFIGURED
IN A "MANUAL ON" CONFIGURATION. •••
CLG MTD SENSOR. PROVIDE W/ POWER PACK & RELAYS FOR PLUG LOAD & HVAC CONTROL. LETTERS "ab" INDICATE ZONES
CONTROLLED. "xx" INDICATES THE FOLLOWING:

OS: DUAL TECHNOLOGY OCCUPANCY SENSOR
P: PHOTOCELL
OP: COMBINATION PHOTOCELL AND DUAL TECHNOLOGY
OCCUPANCY SENSOR.

WALL MTD COMBINATION OCCUPANCY SENSOR & DIMMER
SWITCH, MTG HEIGHT PER ADA - UNO OR REQ. LETTERS "ab"
INDICATE ZONES CONTROLLED.

LOW VOLTAGE MANUAL ON/OFF, DIMMING & MULTI BUTTON
SCENE SELECT CONTROL STATION. "#" DENOTES NUMBER OF
SCENE. LETTERS "ab" INDICATE ZONES CONTROLLED.

LOW VOLTAGE MANUAL ON/OFF & SINGLE ZONE DIMMING
CONTROL.

XX
ab
ab
xx
ab
o
ab
v
SZ
MS-#
ab
MZ-#
ab
K
SG
••

DUPLEX RECEPTACLE - MTG HEIGHT PER ADA REQUIREMENTS OR
AS NOTED. "C" INDICATES CONTROLLED RECEPTACLE, MUST BE
WITHIN 6'-0" OF UNCONTROLLED RECEPTACLE PER TITLE 24 REQ.

DOUBLE DUPLEX RECEPTACLE, MTG HEIGHT PER ADA
REQUIREMENTS OR AS NOTED.

DUPLEX, GFCI RECEPTACLE, MTG HEIGHT PER ADA
REQUIREMENTS OR AS NOTED. WP INDICATES WEATHERPROOF,
REFER TO THE GENERAL PRODUCT SPECIFICATIONS.

DOUBLE DUPLEX, GFCI RECEPTACLE, MTG HEIGHT PER ADA
REQUIREMENTS OR AS NOTED. WP INDICATES WEATHERPROOF,
REFER TO THE GENERAL PRODUCT SPECIFICATIONS.

DEDICATED 20A DUPLEX RECEPTACLE, MTG HEIGHT PER ADA
REQUIREMENTS OR AS NOTED.

DUPLEX RECEPTACLE WITH USB CONNECTORS - MTG HEIGHT PER
ADA REQUIREMENTS OR AS NOTED.

DOUBLE DUPLEX RECEPTACLE WITH USB CONNECTORS, MTG
HEIGHT PER ADA REQUIREMENTS OR AS NOTED.

EMERGENCY DUPLEX RECEPTACLE - MTG HEIGHT PER ADA
REQUIREMENTS OR AS NOTED. NOTE: TICK MARKS SHOWN ON

ANY DEVICE REPRESENTS RECEPTACLE CONNECTED TO

EMERGENCY CIRCUIT (RED DEVICE) TYPICAL FOR ANY DEVICE IN LEGEND.

SIMPLEX RECEPTACLE, MTG HEIGHT PER ADA REQUIREMENTS OR
AS NOTED.

SPECIAL RECEPTACLE, MTG HEIGHT PER ADA REQUIREMENTS OR
AS NOTED. REFER TO PLAN NOTES.

DUPLEX RECEPTACLE FLUSH IN CLG - MOUNT FLUSH IN FLOOR
WHEN INDICATED IN A FLOOR BOX SYMBOL.

DOUBLE DUPLEX RECEPTACLE FLUSH IN CLG - MOUNT FLUSH IN
FLOOR WHEN INDICATED IN A FLOOR BOX SYMBOL.

SIMPLEX RECEPTACLE FLUSH IN CLG - MOUNT FLUSH IN FLOOR
WHEN INDICATED IN A FLOOR BOX SYMBOL.

SPECIAL RECEPTACLE FLUSH IN CLG - MOUNT FLUSH IN FLOOR
WHEN INDICATED IN A FLOOR BOX SYMBOL.

DUPLEX RECEPTACLE MTD ABOVE COUNTER, MTG HEIGHT PER
ADA REQUIREMENTS - UNO OR REQ.

DOUBLE DUPLEX RECEPTACLE MTD ABOVE COUNTER, MTG
HEIGHT PER ADA REQUIREMENTS - UNO OR REQ.

DUPLEX, GFCI RECEPTACLE MTD ABOVE COUNTER, MTG HEIGHT
PER ADA REQUIREMENTS - UNO OR REQ. WP INDICATES

WEATHERPROOF, REFER TO THE GENERAL PRODUCT
SPECIFICATIONS.

DOUBLE DUPLEX, GFCI RECEPTACLE MTD ABOVE COUNTER, MTG
HEIGHT PER ADA REQUIREMENTS - UNO OR REQ. WP INDICATES

WEATHERPROOF, REFER TO THE GENERAL PRODUCT
SPECIFICATIONS.

SIMPLEX RECEPTACLE MTD ABOVE COUNTER, MTG HEIGHT PER
ADA REQUIREMENTS - UNO OR REQ.

SPECIAL RECEPTACLE MTD ABOVE COUNTER, MTG HEIGHT PER
ADA REQUIREMENTS - UNO OR REQ.

WALL MOUNTED JUNCTION BOX. MTG HEIGHT AS NOTED. 4S/DP
MIN OR AS REQ BY NEC.

JUNCTION BOX, MTD IN ACCESSIBLE CLG FOR APPLICATION
DENOTED ON PLAN. 4S/DP MIN OR AS REQ BY NEC.

SURFACE MTD MULTI-OUTLET ASSEMBLY. REFER TO GENERAL
PRODUCT SPECIFICATIONS. PROVIDE ALL COMPONENTS
NECESSARY FOR A COMPLETE INSTALLATION.

EXHAUST FAN, OR MOTOR LOAD. REFER TO MECHANICAL,

PLUMBING OR KITCHEN DWG FOR SPECIFIC LOAD REQ OR AS
NOTED.

FLUSH MTD ELECTRICAL PANELBOARD OR LOAD CENTER. REFER
TO PANEL SCHEDULE.

SURFACE MTD ELECTRICAL PANELBOARD OR LOAD CENTER.

REFER TO PANEL SCHEDULE.

DISTRIBUTION SWITCHBOARD. REFER TO SINGLE LINE DIAGRAM.

TRANSFORMER, REFER TO SINGLE LINE DIAGRAM.

FUSED DISCONNECT SWITCH, HP RATED, OR COMBINATION

MOTOR STARTER/DISCONNECT SWITCH W/ FUSES PER
EQUIPMENT MFR & WEATHERPROOF AS REQ. PROVIDE FINAL
CONNECTION TO UNIT EQUIPMENT. SEE MOTORIZED EQUIPMENT
SCHEDULE FOR DISCONNECT & STARTER SIZES.

MOTOR STARTER COMBINATION SWITCH W/ HOA SELECTOR
SWITCH, ON "RUNNING LIGHT" RESET & OVERLOAD PROTECTION.

NON-FUSED DISCONNECT SWITCH, HP RATED & WEATHERPROOF
AS REQ. PROVIDE FINAL CONNECTION TO UNIT EQUIPMENT. SEE MOTORIZED EQUIPMENT SCHEDULE FOR DISCONNECT SIZES.

UTILITY COMPANY METER. PROVIDE "CT's" & "PT's" AS REQ, REFER TO SINGLE LINE DIAGRAM.

CIRCUIT BREAKER, LINE 1 REPRESENTS FRAME SIZE/RATING; LINE 2 REPRESENTS TRIP SIZE/RATING; LINE 3 REPRESENTS NUMBER OF POLES & LINE 4 REPRESENTS MISC BREAKER INFO. (SEE
BELOW):

SHUNT = PROVIDE SHUNT TRIP MECHANISM.

HACR = PROVIDE HACR-RATED BREAKER.

GFP = GROUND FAULT PROTECTION
CLCB = CURRENT LIMITING CIRCUIT BREAKER
SS = PROVIDE SOLID STATE CIRCUIT BREAKER
FUSIBLE SWITCH: LINE 1 REPRESENTS SWITCH SIZE/RATING; LINE 2 REPRESENTS NUMBER OF POLES; LINE 3 REPRESENTS FUSE
SIZE/RATING; LINE 4 REPRESENTS FUSE TYPE; LINE 5 REPRESENTS MISC FUSE INFO. (SEE BELOW):

SHUNT= PROVIDE SHUNT TRIP MECHANISM.

GFP = GROUND FAULT PROTECTION
CLF = CURRENT LIMITING FUSE
GROUND CONNECTION, SIZE AS INDICATED OR AS REQ.

LOW VOLTAGE TRANSFORMER
PULLBOX, SIZED PER NEC OR AS NOTED.

RECESSED COMBINATION POWER OUTLET FOR IN FLOOR BOX PER
PLAN FOR FLEXIBLE CONNECTION TO FURNITURE SYSTEM. VERIFY

CONNECTION REQ W/ MFR PRIOR TO ROUGH-IN - MOUNT FLUSH IN FLOOR WHEN INDICATED IN A FLOOR BOX SYMBOL.

POWER OUTLET OUTLET, MTG HEIGHT PER ADA DEVICE MT REQ.

FOR FLEXIBLE CONNECTION TO FURNITURE SYSTEM PROVIDE THE FOLLOWING:

IN A NON-RATED INSULATED WALL, OR NON-RATED
UNINSULATED WALL, PROVIDE A 2-GANG MUD RING OR CADDY
#RBS SERIES BOX MTG BRACKET (EQUAL BY B-LINE OR
RAYCO) W/ (2) 1-1/4"CO W/ PULL STRING TO ACCESSIBLE CLG.

PROVIDE 1-1/4" BUSHINGS @ CONDUIT ENDS. REFER TO

ARCHITECTURAL PLANS FOR WALL CONSTRUCTION/TYPE &
CLG CONDITIONS.

IN A RATED WALL, PROVIDE (1) 4S/DP BOX W/ (2) 1-1/4" CO & (1) 4S/DP BOX W/ (1) 1-1/4" CO W/ PULL STRINGS IN EA CONDUIT TO ACCESSIBLE CLG. PROVIDE 1-1/4" BUSHINGS @ CONDUIT ENDS.

UTILIZE CADDY #RBS SERIES BOX MTG BRACKET TO MAINTAIN
BOX ALIGNMENT. (EQUAL BY B-LINE OR RAYCO) UTILIZE

FIRESTOPPING SYSTEM PADS RATED FOR USE ON THE INSIDE

OR OUTSIDE OF THE BOX (STI OR EQ) AS REQ TO MAINTAIN
RATING OF WALL OR MEMBRANE. REFER TO ARCHITECTURAL
PLANS FOR WALL CONSTRUCTION/TYPE & CLG CONDITIONS.

GROUND BUS BAR

POWER SYMBOLS
JJ3TF
T
PB ORP
J
J
150AF
150AT
3P
1 60AS
3P
1 50AF

CLASS J
CTM
Revision Date
408-780-7200 Office
60 South Market Street, Suite 1250
San Jose, California 95113

NOT FOR REGULATORY APPROVAL,

PERMITTING OR CONSTRUCTION

ARCHITECTURE ENGINEERING INTERIOR DESIGN

LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
Developed for
Checked By
Scale
Job Number Submittal Date 70% SCHEMATIC DESIGN 03/10/2026 100% SD / BRIDGING DOCS 03/26/2026 This document and all other project documents, ideas,
aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the
project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.

Project documents describe the design intent of the work and are not a representation of as-built or existing
conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions. © LPA, Inc.
1/8" = 1'-0"

SANTA TERESA FIRE STATION
1330 WEST LUCHESSA AVENUEGILROY, CA 95020
GRIFFIN STRUCTURES, INC.

ELECTRICAL LEGEND &

GENERAL NOTES
E0.01
33236
Checker

Page 248 of 256 ends

1. 2.

3. 4.

5. 6.

7. A.

B.

C.

D.

8. 9.

10. 11.

REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION & ELEVATION OF ALL LIGHTING FIXTURES & ALL DEVICES. ALL WALLMTD DEVICE HEIGHTS SHALL BE VERIFIED WITH THE ARCHITECT PRIOR TO ROUGH-IN. IF ANY WALL MTD FIXTURES ARE

PLACED WITHOUT VERIFICATION FROM THE ARCHITECT, DESIGN-BUILD ENTITY SHALL RELOCATE FIXTURE TO APPROVED LOCATION AT NO ADDITIONAL COST.

VERIFY EXACT CLG CONSTRUCTION W/ ARCHITECTURAL REFLECTED CLG PLAN & PROVIDE LIGHTING FIXTURES W/ ALL NECESSARY MTG HARDWARE.

ALL RECESSED FIXTURES SHALL BE PROVIDED W/ ALL REQ STRUCTURAL SUPPORTS AS REQ BY THE CURRENTLY ADOPTED ISSUE OF THE UNIFORM BUILDING CODE, AS WELL AS ANY LOCAL CODES.

ALL COVE MTD FIXTURES SHALL EXTEND THE FULL LENGTH OF THE COVE. DESIGN-BUILD ENTITY TO FIELD MEASURE COVE LENGTH & ORDER QTY OF FIXTURES AS REQ.

ALL DIMMING BRANCH CIRCUITS SHALL BE PROVIDED W/ A DEDICATED NEUTRAL CONDUCTOR FOR EACH ZONE/CHANNEL.

REFER TO ARCHITECTURAL REFLECTED CLG PLANS FOR EXIT SIGN CHEVRONS & NUMBER OF FACES PER EXIT SIGN.AND/ANY

DISCREPANCIES BETWEEN EXIT SIGNS SHOWN ON THE ELECTRICAL & ARCHITECTURAL PLANS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO ORDERING EXIT SIGNS.

WHEN EXPOSED CLG OR OPEN GRID CONDITIONS OCCUR, THE DESIGN-BUILD ENTITY WILL NEED TO PROVIDE THE FOLLOWING ITEMS:

ALL BRANCH CIRCUITS SHALL BE IN EMT.

ALL BRANCH CIRCUITS SHALL BE ROUTED NEATLY TRAINED & IN PARALLEL TO STRUCTURES OR DUCT WORK. THE TERM “TRAINED” MEANS ALL PARALLEL CONDUITS SHALL MAINTAIN THE SAME SPATIAL RELATIONSHIP W/ EA OTHER FOR ENTIRE RUN TO INCLUDE RADIUS BENDS & SWEEPS.

VISUALLY OBJECTIONABLE BRANCH CIRCUITS WILL BE REROUTED AT THE REQUEST OF THE ARCHITECT AT NO ADDL COST.

SHOP DWG SHOWING LOCATION & PLACEMENT OF ALL CONDUITS.

RECESSED FIXTURES LOCATED IN A FIRE-RATED CLG OR WALL SHALL BE PROVIDED WITH A 5-SIDED RATED ENCLOSURE SO CONSTRUCTED AS TO ALLOW CODE & MFR-REQ CLEARANCES BETWEEN THE FIXTURE & THE ENCLOSURE.

REFER TO GENERAL POWER PLAN NOTES & COMMUNICATIONS PATHWAYS GENERAL NOTES FOR ADDITIONAL REQ WHEN POWER AND/OR DATA DEVICES ARE SHOWN ON THIS PLAN.

DESIGN-BUILD ENTITY TO INCLUDE AN ALLOWANCE TO CORE & SEAL PENETRATIONS THROUGH STRUCTURAL CONCRETE WALLS. COORDINATE LOCATIONS & REQ W/ ARCHITECTURAL & STRUCTURAL DWGS.

COORDINATE ALL PENETRATIONS W/ STRUCTURAL PLANS & DETAILS. NO PENETRATIONS ARE PERMITTED UNLESS SPECIFICALLY NOTED ON STRUCTURAL DWGS.

LIGHTING GENERAL NOTES

1. 2.

3. 4.

5. 6.

A.

B.

C.

7. 8.

9. 10.

11. ALL RECEPTACLES ON COMMON WALLS SHALL BE SEPARATE BOXES & OFFSET 24" MIN.

ALL PENETRATIONS THROUGH FIRE RATED WALLS SHALL BE PROTECTED FROM THE SPREAD OF FIRE W/ AN APPROVED FIRESTOP SYSTEM EQ OR GREATER THAN THE FIRE RATING OF THE WALL.

COORDINATE ALL MTG DIMENSIONS FOR ELECTRICAL DEVICES & SWITCHES W/ ARCHITECTURAL INT ELEVATIONS PRIOR TO ROUGH-IN.

ALL FURNITURE FEED LOCATIONS TO BE VERIFIED W/ ARCHITECT & FURNITURE VENDOR PRIOR TO ROUGH IN..

ALL FURNITURE WHIPS SHALL BE TRIMMED TO REDUCE EXCESS WHIP LENGTH

WHEN EXPOSED CLG OR OPEN GRID CONDITIONS OCCUR, THE DESIGN-BUILD ENTITY WILL NEED TO PROVIDE THE FOLLOWING ITEMS:

ALL BRANCH CIRCUITS SHALL BE IN EMT.

ALL BRANCH CIRCUITS SHALL BE ROUTED NEATLY & IN PARALLEL TO STRUCTURES OR DUCT WORK.

VISUALLY OBJECTIONABLE BRANCH CIRCUITS WILL BE REROUTED AT THE REQUEST OF THE ARCHITECT @ NO ADDITIONAL COST.

EXPOSED CABLE/CONDUCTORS INSTALLED IN A PLENUM SPACE SHALL CONFORM TO CEC WHERE ADOPTED, ARTICLE 300.22(C.

PROVIDE GFCI TYPE RECEPTACLE(S) WITHIN 6 FT OF ANY SINK.

DESIGN-BUILD ENTITY TO INCLUDE AN ALLOWANCE TO CORE & SEAL PENETRATIONS THROUGH STRUCTURAL CONCRETE WALLS. COORDINATE LOCATIONS & REQ W/ ARCHITECTURAL & STRUCTURAL DWG.

COORDINATE ALL PENETRATIONS W/ STRUCTURAL PLANS & DETAILS. NO PENETRATIONS ARE PERMITTED UNLESS SPECIFICALLY NOTED ON STRUCTURAL DWG.

COORDINATE ALL KITCHEN CONDUIT & EQUIPMENT ROUGH-IN ON KITCHEN DWG

POWER GENERAL NOTES

1. 2.

3. 4.

5. DESIGN-BUILD ENTITY SHALL REFER TO MECHANICAL/PLUMBING & ARCHITECTURAL DWG FOR EXACT LOCATIONS & CHARACTERISTICS OF ALL EQUIPMENT LISTED IN SCHEDULE. ANY MODIFICATIONS AND/OR ADDITIONAL WORK NECESSARY SHALL BE INCLUDED IN THE BASE BID.

DESIGN-BUILD ENTITY SHALL VERIFY THE EXACT LOCATION OF ALL CONNECTION POINTS W/ THE EQUIPMENT INSTALLER PRIOR TO ROUGH-IN.

DESIGN-BUILD ENTITY SHALL PROVIDE LOCAL REMOTE DISCONNECTING MEANS FOR ALL ELECTRIC HEATING EQUIPMENT IF REQ BY THE LOCAL ELECTRICAL CODE.

DESIGN-BUILD ENTITY SHALL COORDINATE THE ROUTING OF CONDUIT/WIRING TO ROOF-MTD EQUIPMENT W/ EQUIPMENT INSTALLER PRIOR TO ROUGH-IN. WHERE ROOF-MTD EQUIPMENT IS MFR TO BE FED FROM WITHIN MECHANICAL CURB ASSEMBLY - SEPARATE ROOF PENETRATIONS FOR WIRING CONNECTIONS SHALL NOT BE PERMITTED. ALL WIRING SHALL BE BELOW THE ROOF IN AN ACCESSIBLE CLG SPACE LOCATION.

ALL ROOF MTD EQUIPMENT SHALL BE NEMA 3R RATED.

ROOF GENERAL NOTES

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

13. CONDUITS SHALL, (a) CONTAIN NO CONTINUOUS SECTIONS LONGER THAN 30M (98 FT.), AND, (b) CONTAIN NO MORE THAN (2) 90° BENDS OR (1) REVERSE BEND WITHOUT INSTALLING A PULLBOX. CONDUITS IN PLACE OF PULLBOXES ARE UNACCEPTABLE.

CONDUITS SHALL CONTAIN PLASTIC OR NYLON PULL TAPE RATED AT 200 LBS. WITH A MINIMUM OF 5 FEET OF EXTRA PULL TAPE COILED AT EACH END.

CONDUIT BEND RADIUS SHALL BE (a) A MINIMUM OF 6 TIMES THE INTERNAL CONDUIT DIAMETER FOR CONDUITS 2" IN DIAMETER OR LESS, AND, (b) 10 TIMES THE INTERNAL CONDUIT DIAMETER FOR CONDUITS MORE THAN 2" IN DIAMETER.

TERMINATE CONDUITS AND SLEEVES THAT PROTRUDE THROUGH STRUCTURAL FLOORS 2"-3" ABOVE THE FLOOR SURFACE.

INSTALL BUSHINGS AND BELL ENDS AS REQUIRED ON ALL CONDUITS.

FLEX CONDUIT IS GENERALLY UNACCEPTABLE FOR USE AS A COMMUNICATIONS CONDUIT EXCEPT AT SEISMIC JOINTS AND AS APPROVED IN WRITING BY THE ENGINEER.

ALL UNDER SLAB OR IN-SLAB CONDUITS SHALL BE INSTALLED IN A MANNER THAT PREVENTS WATER INFILTRATION OF THE CONDUIT. IT IS THE DESIGN-BUILD ENTITY'S RESPONSIBILITY TO ENSURE GROUND WATER, RAIN WATER OR CONSTRUCTION

WATER IS PREVENTED FROM ENTERING AND/OR REMOVED FROM THE CONDUITS PRIOR TO PLACEMENT OF COMMUNICATIONS CABLES. SEE SITE UTILITY PLAN NOTES FOR ADDITIONAL UNDERGROUND COMMUNICATIONS CONDUIT SEALING REQUIREMENTS.

CONDUIT(S) SHALL EXIT A PULLBOX ON THE WALL OPPOSITE THE WALL ENTERED.

PROVIDE LABELING OF EACH CONDUIT PER GENERAL ELECTRICAL SPECIFICATIONS.

PROVIDE INTERNAL/EXTERNAL GAS AND WATER TIGHT MECHANICAL SEALING/PLUGGING OF EACH BUILDING ENTRY CONDUIT AS SPECIFIED ELSEWHERE IN THE DRAWINGS AND SPECIFICATIONS.

COORDINATE ALL MOUNTING DIMENSIONS FOR ELECTRICAL DEVICES AND SWITCHES WITH ARCHITECTURAL INTERIOR ELEVATIONS PRIOR TO ROUGH-IN.

COORDINATE ALL PENETRATIONS WITH STRUCTURAL PLANS AND DETAILS. NO PENETRATIONS ARE PERMITTED UNLESS SPECIFICALLY NOTED ON STRUCTURAL DRAWINGS.

ALL PULLBOXES SHALL BE SIZED AND INSTALLED PER ANSI/TIA/EIA-569B. PULLBOXES FOR UNDER FLOOR CONDUIT RUNS ARE NOT PERMITTED UNLESS OTHERWISE NOTED. PULLBOXES FOR OVERHEAD CONDUIT RUNS SHALL BE LOCATED ABOVE

ACCESSIBLE CEILINGS WITHIN THE ACCESSIBLE CEILING SPACE AND SUPPORTED INDEPENDENTLY FROM THE STRUCTURE AND CONDUIT SUPPORTS. PULLBOXES FOR ROOF MOUNTED OR EXTERIOR ABOVE GRADE APPLICATIONS SHALL BE NEMA 3 RATED. PULLBOXES SHALL BE SIZED ACCORDING TO THE FOLLOWING CHART:

LOW VOLTAGE GENERAL NOTES

CONDUIT

SIZE LENGTH WIDTH DEPTH WIDTH INCREASE PER ADDITIONAL CONDUIT 1" 4" 16" 3" 2"
2" 8" 36" 4" 5"
3" 12" 48" 5" 6"
4" 15" 60" 8" 8"

1. 2.

3. 4.

5. 6.

7. 8.

9. 10.

11. 12.

13. 14.

15. 16.

17. 18.

19. 20.

21. 22.

THESE NOTES ESTABLISH MIN QUALITY LEVELS & COORDINATION REQ RESPECTIVE UTILITY COMPANY PLANS & REQ TAKE PRECEDENCE OVER THESE NOTES WITH REGARD TO RESPECTIVE UTILITY COMPANY CONDUIT & UNDERGROUND STRUCTURE SYSTEMS.

CALL UNDERGROUND SERVICE ALERT (USA) AT 1 (800) 422-4133 OR APPLICABLE STATE & LOCAL DIG SAFE OR UNDERGROUND ALERT HOTLINES PRIOR TO CONSTRUCTION START.

COORDINATE ALL UNDERGROUND STRUCTURES & CONDUIT ROUTING W/ LANDSCAPE ARCHITECT PRIOR TO ROUGH-IN TO ENSURE THAT SUCH ITEMS ARE NOT PLACED IN CRITICAL LANDSCAPE PLANTING/HARDSCAPE AREAS.

VAULTS, MAINTENANCE HOLES (MH's) & CONDUITS SHALL MAINTAIN A MIN COVER OF 24" BELOW FINAL SURFACE @ ALL CONDITIONS.

INCLUDE ALL COSTS IN BASE BID TO MEET UTILITY COMPANY REQ WHICH MAY REQ GREATER MIN CONDUIT DEPTHS.

VAULTS, MH's & PULLBOXES (PB's) SHALL BE EQUIPPED WITH KNOCKOUT PANELS OR PRE-CAST INDIVIDUAL CONDUIT OPENINGS. CONDUITS SHALL ONLY ENTER & EXIT ON END/SHORT WALLS. CONDUITS MAY NOT ENTER & EXIT ON SIDE/LONG WALLS, CLG OR FLOORS UNO.

CUT DUCTS FLUSH W/ INTERIOR VAULT/MH/PB WALL.

GROUT AROUND DUCT ENTRANCES ON VAULT/MH/PB WALLS.

SLURRY BACKFILL AROUND DUCTS WITHIN 5 FT OF VAULT/MH/PB TO PREVENT SHEARING.

CONDUITS PASSING UNDER THE BUILDING PERIMETER SHALL BE ENCASED IN LIGHTWEIGHT CONCRETE OR WATER-IMPERVIOUS CLAY TO PREVENT WATER INFILTRATION. SEE ELECTRICAL SPECIFICATIONS FOR ADDL INFO.

CONDUIT BEND RADIUS FOR BUILDING ENTRANCES & AT POLES SHALL BE A MIN OF 24" FOR CONDUITS W/ LESS THAN 2" INTERNAL DIA AND A MIN OF 48" FOR CONDUITS W/ MORE THAN 2" INTERNAL DIA.

PREFERRED CONDUIT SWEEP RADIUS BETWEEN VAULTS IS 25 FT. UNDER NO CIRCUMSTANCES SHALL THE CONDUIT SWEEP RADIUS BE LESS THAN 12.5 FT. MAX OF 90° PER SWEEP & LIMITED TO NO MORE THAN (2) 90° WEEPS BETWEEN VAULTS.

VAULTS/MH's/PB's ARE TO BE EQUIPPED W/ RACKING, GROUNDING LUGS, & BOLT-DOWN LIDS UNO.

VAULTS & MH's TO BE EQUIPPED W/ ROUND COVERS, EXTENSION RINGS AS REQ, LADDERS & (3) SEGMENTS OF 6 FT HIGH CABLE RACKING PER EA LONG WALL.

LABEL ALL NON-UTILITY COMMUNICATION VAULT/MH/PB COVERS W/ "COMMUNICATIONS" UNO ON PLANS.

COORDINATE FINAL VAULT/MH/PB OPENING HEIGHT W/ GC PRIOR TO ROUGH-IN TO ENSURE FINAL GRADE DOES NOT SLOPE INTO VAULT/MH/PB OPENING.

DESIGN-BUILD ENTITY TO PROVIDE A MIN OF 8" DEEP COMPACTED 1/2" DIA GRAVEL, UNDER ALL VAULTS, MH's OR PB's TO ENSURE UNIFORM DISTRIBUTION OF SOIL PRESSURE ON THE FLOOR & BE ABLE TO DISSIPATE WATER OUT OF THE VAULT, MH OR PB.

ALL VAULTS/MH's/PB's W/O GROUNDING LUGS SHALL HAVE AN 8' x 3/4" COPPER GROUND ROD DRIVEN THRU THE FLOOR TO ALLOW GROUNDING OF ITEMS WITHIN.

ALL VAULTS/MH's/PB's SHALL BE PROVIDED W/ TRAFFIC RATED COVERS WHEN LOCATED IN PAVED AREAS UTILIZED FOR VEHICLE TRAFFIC.

IF THE WATER OR MOISTURE BARRIER ON OR NEAR THE FOUNDATION OF A BUILDING IS DISTURBED IN ANY MANNER BY EXCAVATION OR OTHER CONSTRUCTION WORK. THE MOISTURE BARRIER MUST BE REPAIRED FOLLOWING THE RECOMMENDATIONS OF THE MFR OF THE ORIGINAL BARRIER PRODUCT.

THE DESIGN-BUILD ENTITY SHALL INCLUDE IN BASE BID ALL COSTS TO COMPLY WITH ALL REQ FOR CONFINED SPACE ENTRY PER THE OSHA REQ 29 CFR-1910.146, 29 CFR-1910.268, ETC DURING ANY CONFINED SPACE ENTRY.

ANY DUCTS LEAVING A VAULT, MH OR PB ROUTED INTO A FACILITY SHALL BE PLUGGED AT EA END USING REMOVEABLE MECHANICAL PLUGS DESIGNED TO PREVENT WATER & GAS FROM ENTERING THE FACILITY.

SEE ELECTRICAL SPECIFICATIONS & PLAN DETAILS FOR ADDL REQ REGARDING UNDERGROUND CONDUITS & IN-GRADE VAULT/MH/PB/JUNCTION BOXES.

INSTALL MULE TAPE OR 3/8" PULL ROPE & TRUE-TAPE IN EA UTILITY CONDUIT.

SITE UTILITY PLAN GENERAL NOTES

1. 2.

3. A.

B.

C.

D.

4. 5.

6. 7.

8. 9.

10. 11.

12. 13.

14. 15.

16. 17.

18. 19.

20. 21.

22. 23.

24. 25.

26. 27.

28. 29.

30. 31.

32. 33.

34. 35.

36. 37.

38. 39.

THE DESIGN-BUILD ENTITY (DBE) SHALL INCLUDE & PROVIDE IN BID ALL LABOR & MATERIALS NECESSARY FOR A COMPLETE & OPERATIONAL INSTALLATION OF ALL ELECTRICAL SYSTEMS.

DBE SHALL COORDINATE & OBTAIN ALL APPROVALS, PERMITS, & DOCUMENTS FROM REGULATORY AGENCIES & UTILITY COMPANIES.

ALL CONDUIT RACEWAY SYSTEMS ARE TO BE INSTALLED AS FOLLOWS:

RIGID GALVANIZED STEEL IS TO BE INSTALLED IN ALL AREAS WHICH ARE EXPOSED TO WEATHER AND/OR PHYSICAL DAMAGE.

FLEXIBLE METALLIC CONDUIT I S PERMITTED FOR SHORT CONNECTIONS TO LIGHT FIXTURES (6'-0" MAX).

FLEXIBLE CONDUIT SHALL ALSO BE INSTALLED FOR EQUIPMENT REQ VIBRATION ISOLATION & HORIZONTAL RUNS IN WOODEN STUD WALLS. ELECTRICAL METALLIC TUBING (EMT) W/ COMPRESSION TYPE FITTINGS SHALL BE USED FOR BUILDING INTERIOR WORK.

PVC CONDUIT SHALL BE USED FOR UNDERGROUND CONDUITS. ROUTE CODE SIZED GROUND WIRE INSIDE OF CONDUIT. CONDUIT RISERS & STUBS ABOVE GRADE SHALL BE IMC WITH HALF-LAPPED TAPE COVERING OR PVC COATING & UTILITY COMPANIES.

UNO OR REFERENCED ON THE DWG ALL NEW ELECTRICAL WIRING IS TO BE 600V RATED COPPER W/ TYPE "THHN/THWN" INSULATION.

ALL MTG HEIGHTS REFERENCED ON DWG ARE MEASURED FROM FINISHED FLOOR UNLESS OTHERWISE REFERENCED OR INDICATED ON THE DRAWINGS.

ALL ELECTRICAL EQUIPMENT LOCATIONS (LIGHTING, RECEPTACLE, FLOOR BOX, ETC) ARE TO BE VERIFIED WITH THE ARCHITECT AND/OR EQUIPMENT SUPPLIER PRIOR TO BEGINNING ANY ROUGH-IN.

ALL LIGHTING FIXTURES SHALL BE MTD & SUPPORTED IN ACCORDANCE W/ OSHA STANDARDS, & ALL STATE, LOCAL, SEISMIC, & CALIFORNIA ELECTRIC CODES.

THE DWG INCLUDED IN THIS DOCUMENT SET ARE DIAGRAMMATIC. THEY ARE REPRESENTATIVE OF THE ENGINEER OF RECORDS DESIGN INTENT FOR ALL ELECTRICAL DEVICES/EQUIPMENT & THE INDIVIDUAL POWER FEEDS THEY ARE TO BE CONNECTED TO. THE DBE SHALL BE

RESPONSIBLE FOR PROVIDING ALL J-BOXES, CONDUIT, WIRING/CABLING, ETC AS REQ FOR A COMPLETE & OPERATIONAL ELECTRICAL INSTALLATION.

ALL ELECTRICAL EQUIPMENT (PANELS, RECEPTACLES, J-BOXES, ETC.) SHALL BE WEATHERPROOF AND/OR INSTALLED IN A NEMA 3R ENCLOSURE WHERE APPLICABLE OR INSTALLED OUTDOORS.

ALL ELECTRICAL WORK SHALL BE PERFORMED ACCORDING TO STATE, LOCAL, NATIONAL, & DISTRICT STANDARDS & CODES. COORDINATE SPECIFIC REQ W/ DISTRICT STANDARDS & AUTHORITY HAVING JURISDICTION.

ALL ELECTRICAL EQUIPMENT SHALL BE NEW & IS TO BE CLEARLY LABELED/IDENTIFIED AS UNDERWRITER LABORATORIES (UL) COMPLIANT UNO OR REFERENCED IN THE DWG OR SPECIFICATIONS.

DBE IS RESPONSIBLE FOR SECURING ALL REQ BUILDING PERMITS & SHALL INCLUDE THE COST TO SECURE BUILDING PERMITS IN THEIR FINAL BID.

UNLESS OTHERWISE WRITTEN, STATED, OR REFERENCED IN DWG OR SPECIFICATIONS DESIGN-BUILD ENTITY SHALL GUARANTEE THE COMPLETE ELECTRICAL INSTALLATION FOR A PERIOD OF 1-YEAR.

ALL ELECTRICAL DISTRIBUTION EQUIPMENT (PANELS, DISTRIBUTION BOARDS, TRANSFORMERS, ETC), FEEDERS (CONDUIT, CONDUCTOR SIZE, & QUANTITY), MECHANICAL EQUIPMENT, ELEVATORS, VARIABLE FREQUENCY DRIVES (VFD'S), ETC. MAY ONLY BE REFERENCED ON THE SINGLE-LINE DWG & NOT INDIVIDUAL PLAN SHEETS. DBE SHALL REVIEW & VERIFY ALL REFERENCED INFORMATION ON THE SINGLELINE DWG.

DBE SHALL BE RESPONSIBLE FOR ALL REQ SAW-CUTTING, CORE DRILLING, PATCHING, REFINISHING, ETC AS REQ FOR INSTALLATION OF ELECTRICAL EQUIPMENT & SYSTEMS. ANY PENETRATIONS OR OPENINGS MADE IN WALLS OR STRUCTURES SHALL BE PATCHED AND/OR SEALED AS REQ TO MAINTAIN THE INTEGRITY AND/OR RATING OF THE WALL OR STRUCTURE.

DBE SHALL VISIT THE SITE PRIOR TO SUBMISSION OF THEIR FINAL BID TO VERIFY ALL EXG SITE CONDITIONS WHICH MAY AFFECT THE COMPLETION OF THE ELECTRICAL INSTALLATION. ALL METHODS & REQUIREMENTS FOR INSTALLATION SHALL BE DETERMINED PRIOR TO BID DATE. ELECTRICAL DBE SHALL NOTIFY THE ENGINEER OF RECORD OF ANY REQ MODIFICATIONS WHICH ARE NOT REFERENCED ON THESE ELECTRICAL PLANS. SUBMITTAL OF THE DBE'S BID DEMONSTRATES THE DESIGN-BUILD ENTITY'S AWARENESS OF ALL SITE CONDITIONS & REQ WORK TO BE PERFORMED.

ALL CLGS & CLG SYSTEMS AS A RULE ARE CONSIDERED TO BE INACCESSIBLE. ALL ELECTRICAL DEVICES & EQUIPMENT INSTALLED ABOVE CLGS ARE TO BE MTD IN A LOCATION WHICH IS ACCESSIBLE. IN SITUATIONS WHERE ELECTRICAL DEVICES & EQUIPMENT MUST BE

INSTALLED IN AN AREA WHICH IS INACCESSIBLE, DBE SHALL INSTALL AN ADEQUATELY SIZED, CODE COMPLIANT ACCESS PANEL AS REQ BY

CURRENT CODES - LOCATION OF THE REQ ACCESS PANEL SHALL BE COORDINATE W/ THE ARCHITECT & INTERIOR DESIGNER PRIOR TO ROUGH-IN.

DBE IS RESPONSIBLE FOR COMPLETING ALL FINAL ELECTRICAL CONNECTIONS TO OWNER FURNISHED EQUIPMENT & SHALL PROVIDE ALL MOTOR START SWITCHES, DISCONNECTS, ETC AS REQ.

ALL ELECTRICAL EQUIPMENT CONNECTIONS, MOUNTING LOCATIONS, ELECTRICAL REQUIREMENTS, ETC ARE TO BE COORDINATED & VERIFIED PRIOR TO COMMENCEMENT OF ELECTRICAL ROUGH-IN.

DBE TO SUBMIT SHOP DWG FOR THE APPROVAL OF THE ELECTRICAL ENGINEER OF RECORD FOR ALL ELECTRICAL EQUIPMENT & MATERIALS TO BE UTILIZED IN THE ELECTRICAL INSTALLATION. ALL APPROVALS BY THE ENGINEER OF RECORD MUST BE SECURED PRIOR TO COMPLETION OF ANY PURCHASE ORDERS OR ROUGH-IN WORK.

THESE ELECTRICAL DWG & ASSOCIATED SPECIFICATIONS ARE TO BE CONSIDERED CONTRACT DOCUMENTS FOR AGENCY REVIEW/APPROVAL & DBE BIDDING PURPOSES.

THE COMPLETE ELECTRICAL SYSTEM SHALL BE GROUNDED IN ACCORDANCE WITH CEC ARTICLE 250. ALL POWER & LIGHTING CIRCUITS SHALL BE INSTALLED WITH A MIN #12AWG CU GROUND WIRE UNO OR REFERENCED.

DBE TO PROVIDE ENGRAVED PHENOLIC NAMEPLATES ON ALL DISCONNECT SWITCHES, DISTRIBUTION EQUIPMENT, J-BOXES ETC. W/ METALLIC COVERS. SEE GENERAL NOTES ON SINGLE-LINE DIAGRAM FOR SPECIFIC INFORMATION REGARDING NAME PLATE REQ.

ELECTRICAL & LIGHTING COVER PLATE COLOR, ENGRAVING & LABELING PER SPECIFICATIONS.

AT THE COMPLETION OF THE PROJECT THE DBE SHALL PROVIDE THE OWNER WITH A COMPLETE SET OF AS-BUILT ELECTRICAL DWG.

ANY & ALL WORK THAT REQ AN INTERRUPTION TO A BUILDING(S) ELECTRICAL SERVICE MUST BE COORDINATED W/ THE DISTRICT A MIN OF 48 HOURS IN ADVANCE. ANY SERVICE DOWNTOWN SHALL NOT OCCUR DURING SCHOOL HOURS.

DBE SHALL BE RESPONSIBLE FOR FOR ENSURING THAT ALL LOW VOLTAGE SYSTEMS ARE COMPATIBLE & ARE COMPLETE & OPERATIONAL.

DBE SHALL PERMANENTLY TAG ALL CONDUCTORS IN EA ELECTRICAL & LOW VOLTAGE SYSTEM AS REFERENCED IN THE SPECIFICATIONS.

ANY SURFACE MTD EXPOSED CONDUIT IN VIEW OF THE PUBLIC SHALL BE PAINTED TO MATCH THE FINISH OF THE SURFACE TO WHICH IT IS MTD WITH TWO (2) COATS OF PAINT. ALL EXT SURFACE MTD EXPOSED CONDUITS ARE TO BE PAINTED W/ TWO (2) COATS OF WEATHERPROOF LATEX PAINT.

DBE TO PROVIDE ALL CONDUIT ONLY (CO) INFRASTRUCTURE WITH A 3/16" NYLON PULL ROPE. LABEL PULL ROPE AT EACH END W/ THE LOCATIONS OF ORIGIN & TERMINATION.

IN INSTANCES WHERE A CONFLICT BETWEEN THE ELECTRICAL DWG & THE SPECIFICATIONS FOR THE PROJECT EXISTS, THE DBE SHALL ADHERE TO THE MORE STRINGENT REQ.

ELECTRICAL DWG ARE DIAGRAMMATIC. AS SUCH, ALL ELECTRICAL EQUIPMENT LOCATIONS, CONDUIT ROUTING, ETC ARE NOT PRECISE & SHALL BE COORDINATED, VERIFIED, & DETERMINED IN THE FIELD. DBE TO INSTALL ALL ELECTRICAL EQUIPMENT & ROUTE ALL CONDUITS IN

LOCATIONS WHICH MEET CODE REQ FOR ACCESSIBILITY/MOUNTING & DO NOT INTERFERE W/ ANY BUILDING STRUCTURES, UTILITIES, OR OTHER TRADE EQUIPMENT.

ALL EXG SITE RELATED ELECTRICAL EQUIPMENT (I.E. UNDERGROUND UTILITIES, DUCTS, STRUCTURES, PULL BOXES, ETC.) LOCATIONS ARE DIAGRAMMATIC IN NATURE & ONLY REFLECT APPROXIMATE LOCATIONS, QUANTITIES, &/OR ROUTING INFORMATION. ALL REFERENCED

INFO HAS EITHER BEEN SURVEYED, REPORTED BY THE OWNER/OWNERS REP, AND/OR REFERENCED ON AN AS-BUILT RECORD DOCUMENTS. ALL EXG ELECTRICAL EQUIPMENT REFERENCED ON THESE DWG IS TO BE FIELD VERIFIED BY THE DESIGN-BUILD ENTITY

PRIOR TO COMMENCEMENT OF BY ACCEPTING THESE PLANS OR PROCEEDING WITH ELECTRICAL SCOPE OF WORK, AGREES TO ACCEPT

LIABILITY & SHALL RENDER THE ENGINEER OF RECORD HARMLESS FOR ANY ELECTRICAL EQUIPMENT NOT REPORTED TO THE ENGINEER DURING THE DESIGN PROCESS. THE CONTRACT TO TAKE THE REQ PRECAUTIONARY MEASURES TO ENSURE ALL EXG ELECTRICAL EQUIPMENT IS PROTECTED IN PLACE.

ANY EXG BUILDING STRUCTURES OR SURFACES DAMAGED BY DEMOLITION OR DURING INSTALLATION ACTIVITIES SHALL BE REPAIRED, PATCHED, AND/OR REFINISHED TO THE SATISFACTION OF THE OWNER.

ALL EXG ELECTRICAL EQUIPMENT INDICATED TO BE DEMOLISHED SHALL BE REMOVED ENTIRELY & ALL AFFECTED SURFACES OR STRUCTURES SHALL BE REPAIRED, REPLACED, AND/OR REFINISHED TO MATCH THE ADJACENT SURFACES OR DAMAGED ITEM(S).

FOR CLARITY ONLY RECONSTRUCTION OR NEW WORK RELATED ELEMENTS & SELECT EXISTING FACILITIES SPECIFICALLY REQ COORDINATION W/ ANY NEW WORK.

ALL CONDUITS, BOXES, SURFACE MTD RACEWAYS, SUPPORT DEVICES, & ASSOCIATED FITTINGS SHALL BE MTD IN CONCEALED LOCATIONS

ABOVE CLG, DUCTS, TRUSSES, BEAMS, ETC IN AREAS WHERE A CONCEALED MTG LOCATION IS NOT AVAILABLE EQUIPMENT SHALL BE PAINTED TO MATCH THE ADJACENT SURFACES.

ANY PENETRATIONS BY CONDUITS OR OTHER ELECTRICAL EQUIPMENT THROUGH A FIRE RATED WALL - WHETHER EXG OR NEW - SHALL MAINTAIN THE APPROPRIATE FIRE RATING BY SEALING THE PENETRATION W/ THE APPROPRIATE UL-LISTED FIRE-STOP MATERIAL/SYSTEM.

DESIGN-BUILD ENTITY SHALL PREPARE & SUBMIT THE FOLLOWING CALIFORNIA ENERGY COMMISSION T-24 CERTIFICATE OF ACCEPTANCE LTG-1-1, PARTS 1, 2, & 3; LIGHTING CONTROL LTG-2-A; AND/OR AUTOMATIC DAYLIGHTING CONTROL LTG-3-A, AS THEY APPLY TO THE BUILDING DEPARTMENT PRIOR TO ISSUANCE OF THE CERTIFICATE OF OCCUPANCY.

GENERAL NOTES

1. 2.

3. 4.

5. 6.

7. 8.

ALL INFO REFERENCED IS PRELIMINARY IN NATURE & DOES NOT REPRESENT FINAL DESIGN DOCUMENTS. ALL INFO & REQ RELATIVE TO UTILITY INFRASTRUCTURE SHALL BE COORDINATED, VERIFIED, & INSTALLED PER FINAL UTILITY COMPANY DESIGN DOCUMENTS.

ROUTING OF ALL CONDUIT SHALL BE COORDINATED IN THE FIELD & CONFIRMED BY ENGINEER & ARCHITECT.

COORDINATE ALL CONDUIT ROUTING, ELECTRICAL DEVICE LOCATIONS, PULL BOX LOCATIONS, ETC W/ LANDSCAPE PLANTING PLANS TO AVOID CONFLICTS W/ TREES, SHRUBS, ETC.

ALL CONDUCTOR & CABLE RUNS ARE TO BE CONTINUOUS. NO CONDUCTORS OR LOW VOLTAGE CABLING TO BE INSTALLED AS PART OF INCREMENT ONE. ALL CONDUCTORS & LOW VOLTAGE CABLING TO BE INSTALLED AS PART OF INCREMENT TWO & TERMINATED INSIDE OF THE BUILDING.

ALL CONDUIT SHALL BE PROVIDED W/ PROPERLY SIZED PULL STRING PER UTILITY COMPANY STANDARDS.

ALL EQUIPMENT MTD OUTDOORS SHALL BE INSTALLED IN A WEATHERPROOF NEMA 3R ENCLOSURE.

SEE ARCHITECTURAL/LANDSCAPE ARCHITECTURAL PLANS FOR EXACT LOCATIONS OF FIXTURES, PULL BOXES, MANHOLES, OTHER ELECTRICAL DEVICES, ETC. COORDINATE ALL UNDERGROUND STRUCTURES & CONDUIT ROUTING W/ LANDSCAPE ARCHITECT PRIOR TO ROUGH-IN TO ENSURE THAT SUCH ITEMS ARE NOT PLACED IN CRITICAL LANDSCAPE PLANTING/HARDSCAPE AREAS.

PROVIDE CONCRETE ENCASEMENT FOR ALL TRENCHES W/ MORE THAN THREE (3) CONDUITS. ALL UTILITY CONDUIT SHALL BE ENCASED PER UTILITY COMPANY REQUIREMENTS.

ADDITIONAL NOTES
Revision Date
408-780-7200 Office
60 South Market Street, Suite 1250
San Jose, California 95113

NOT FOR REGULATORY APPROVAL,

PERMITTING OR CONSTRUCTION

ARCHITECTURE ENGINEERING INTERIOR DESIGN

LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
Developed for
Checked By
Scale
Job Number Submittal Date 70% SCHEMATIC DESIGN 03/10/2026 100% SD / BRIDGING DOCS 03/26/2026 This document and all other project documents, ideas,
aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the
project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.

Project documents describe the design intent of the work and are not a representation of as-built or existing
conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions. © LPA, Inc. SANTA TERESA FIRE STATION
1330 WEST LUCHESSA AVENUEGILROY, CA 95020
GRIFFIN STRUCTURES, INC.

ELECTRICAL GENERAL
NOTES
E0.02
33236
Checker

Page 249 of 256 ends
Page 250 of 256 ends
Page 251 of 256 ends

W D
DW
REF.

MW
CM
HOSE

STORAGE
TV TV
MIRROR
COMP
MB
TV

PRINTER

PRINTER
TV
COMP
COMP
COMP
COMP
WH

EXTRACTOR
DRYING
RACK
COMP
.

RH
.

TV
AC
TV
MB
REF.

ICE
CG
CG
CG CG
CG CG
CG CG

CG CGCG
CG
CG
CG
CG
CGCG

CGCG CG
CG CG
CGCG
CGCG
CG
CG
CG CG
WP WP
WP
WP
WP
WP
J
CLNG

CLNG CLNG
J J J
J J J
WP WP
J
J
CLNG
CLNG

CLNG CLNG CLNG
1 A
2 3 4 5 6
B
C
D
E
F
7 8
E2.01
1 MDF
E-1404
E-1401
E-1405
E-1405
E-1405
E-1403
E-1402
E-1401
E-1406
3 4
E
MSB
UGPS

PP MP LP
ATS-1 LCP
SP
FUTURE
SOLAR
Revision Date
408-780-7200 Office
60 South Market Street, Suite 1250
San Jose, California 95113

NOT FOR REGULATORY APPROVAL,

PERMITTING OR CONSTRUCTION

ARCHITECTURE ENGINEERING INTERIOR DESIGN

LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
Developed for
Checked By
Scale
Job Number Submittal Date 70% SCHEMATIC DESIGN 03/10/2026 100% SD / BRIDGING DOCS 03/26/2026 This document and all other project documents, ideas,
aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the
project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.

Project documents describe the design intent of the work and are not a representation of as-built or existing
conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions. © LPA, Inc.

As indicated

SANTA TERESA FIRE STATION
1330 WEST LUCHESSA AVENUEGILROY, CA 95020
GRIFFIN STRUCTURES, INC.

ELECTRICAL POWER
PLANS
E2.01
33236
Checker

KEYNOTES

ITEM DESCRIPTION
E-1401 PROVIDE ELECTRICAL CONNECTION TO OVERHEAD DOOR
MOTORS AND CONTROL SWITCH. COORDINATE WITH
MANUFACTURER FOR POWER REQUIREMENTS. COORDINATE

WITH OWNER FOR EXACT LOCATION PRIOR TO ROUGH IN AND
INSTALLATION.

E-1402 PROVIDE ELECTRICAL CONNECTION TO WIRELESS REPEATER.

COORDINATE WITH CITY/ MANUFACTURER FOR POWER
REQUIREMENTS. MOUNT REPEATER AT 16' AFF. COORDINATE

LOCATION OF STUB UPS WITH OWNER PRIOR TO ROUGH IN AND
INSTALLATION.

E-1403 PROVIDE ELECTRICAL CONNECTION TO GPS REPEATER.

COORDINATE WITH CITY/ MANUFACTURER FOR POWER
REQUIREMENTS. MOUNT GPS REPEATER AT 12' AFF. COORDINATE

LOCATION OF STUB UPS WITH OWNER PRIOR TO ROUGH IN AND
INSTALLATION.

E-1404 PROVIDE ELECTRICAL AND DATA CONNECTION TO FIRE
ALERTING SCREEN. COORDINATE WITH MANUFACTURER FOR
POWER AND DATA REQUIREMENTS. COORDINATE LOCATION WITH
OWNER PRIOR TO ROUGH IN AND INSTALLATION.

E-1405 PROVIDE ELECTRICAL CONNECTION TO CORD REEL ASSEMBLY.

MOUNT CORD REEL AT 10' AFF. COORDINATE LOCATION WITH
OWNER PRIOR TO ROUGH IN AND INSTALLATION.

E-1406 PROVIDE ELECTRICAL CONNECTION TO CORD REEL ASSEMBLY FOR PLYMOVENT . COORDINATE LOCATION WITH OWNER PRIOR
TO ROUGH IN AND INSTALLATION.
1/8" = 1'-0"
1 - FLOOR - POWER 05
1/4" = 1'-0"
1 - FLOOR - POWER - Callout 1 1

Page 252 of 256 ends

WP
WP
J
J
1 A
2 3 4 5 6
B
C
D
E
F
7 8
TYP.

E-1501
TYP.

E-1502
TYP.

E-1601
TYP.

E-1601
TYP.

E-1601
Revision Date
408-780-7200 Office
60 South Market Street, Suite 1250
San Jose, California 95113

NOT FOR REGULATORY APPROVAL,

PERMITTING OR CONSTRUCTION

ARCHITECTURE ENGINEERING INTERIOR DESIGN

LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
Developed for
Checked By
Scale
Job Number Submittal Date 70% SCHEMATIC DESIGN 03/10/2026 100% SD / BRIDGING DOCS 03/26/2026 This document and all other project documents, ideas,
aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the
project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.

Project documents describe the design intent of the work and are not a representation of as-built or existing
conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions. © LPA, Inc.
1/8" = 1'-0"

SANTA TERESA FIRE STATION
1330 WEST LUCHESSA AVENUEGILROY, CA 95020
GRIFFIN STRUCTURES, INC.

ELECTRICAL

MECHANICAL POWER

ROOF PLANS
E2.13
33236
Checker
1/8" = 1'-0"
2 - FLOOR - POWER / MECH 05

KEYNOTES

ITEM DESCRIPTION
E-1501 PROVIDE DUPLEX GFI RECEPTACLE WITH WEATHER RATED COVER.

E-1502 PROVIDE ELECTRICAL CONNECTION TO ANTENNA SUPPORT AND RADIO CONNECTIVITY VIA UNISTRUT. COORDINATE WITH CITY FOR REQUIREMENTS AND EXACT LOCATION.

E-1601 ALL MECHANICAL EQUIPMENT TO HAVE A DISCONNECT OR MOTOR RATED SWITCH. COORDINATE WITH MANUFACTURER FOR
INFORMATION.

Page 253 of 256 ends

"MSB-SE" 800 AMPS, 120/208V, 3∅-4W
AIC RATING 65kAIC, 100% RATED
CM
1" C, #3/0 AWG CU.

GROUND PER NEC
250-50, 250-52 (A1-3),
250-53(C&D)
1#3/0 AWG CU. EQUIPMENT
BOND PER NEC 250-102(c)
1" C, #3/0 AWG CU. BOND TO

COLD WATER PIPE PER NEC
250-104(A)
T
(N) UTILITY TRANSFORMER

OUTDOOR PAD-MOUNTED

PROVIDED BY PG&E

REQUIREMENTS
M
225AF
200AT
3P
3 SPD
225AF
200AT
3P
6 SWITCHBOARD "MSB"
800 AMPS, 120/208V, 3∅-4W
AIC RATING 65kAIC, 100% RATED

UGPS METER/MAIN
800AF
800AT
3P
LSIG/BIDIR.
2 150AF
125AT
3P
800AF
800AT
3P
1 7 8 9
225AF
200AT
3P
4 225AF
200AT
3P
5 225AF
225AT
3P
30AF
20AT
3P
225AF
225AT
3P
600AF
600AT
3P

FUTURE PV

READILY CONNECTION
"ATS-1"
800A 120/208v

BYPASS/IOSOLATION
AUTO

TRANSFER
SWITCH
350kW/438kVA

DIESEL GENERATOR
120/208V,3∅-4W, NEMA 3R
1#3/0 AWG CU. EQUIPMENT BOND PER NEC 250-120(C)
1"C-#3/0 AWG CU. GROUND PER NEC 250-50, 250-52 (A1-3), 250-53 (C&D) 1"C-#3/0 AWG CU. BOND TO COLD WATER PIPE PER NEC 250-104(A) 800A
3P-100%
RATED

LOAD BANK
350KW/
438KVA
800A
3P-100%
E G
72HR - BELLY TANK
GRD
GRD
GFP
SP
PANEL
MP
PANEL
LP
PANEL
PP
PANEL
MDF
PANEL
10 11
30AF
30AT
3P
SPACE
12 SPACE
###-#
LENGTH = ##'VD = 0.##%
###-#
LENGTH = ##'VD = 0.##%
###-#
LENGTH = ##'VD = 0.##%
###-#
LENGTH = ##'VD = 0.##%
###-#
LENGTH = ##'VD = 0.##%
Revision Date
408-780-7200 Office
60 South Market Street, Suite 1250
San Jose, California 95113

NOT FOR REGULATORY APPROVAL,

PERMITTING OR CONSTRUCTION

ARCHITECTURE ENGINEERING INTERIOR DESIGN

LANDSCAPE ARCHITECTURE PLANNING
LPADesignStudios.com
Developed for
Checked By
Scale
Job Number Submittal Date 70% SCHEMATIC DESIGN 03/10/2026 100% SD / BRIDGING DOCS 03/26/2026 This document and all other project documents, ideas,
aesthetics and designs incorporated therein are instruments of service. All project documents are copyright protected, are the property of LPA, Inc. (LPA) and cannot be lawfully used in whole or in part for any project or purpose except as set forth in the contractual agreement between LPA and its Client. The unauthorized disclosure and/or use of the
project documents (including the creation of derivative works), may give rise to liability for copyright infringement, unlawful disclosure, use or misappropriation of property rights held by LPA. The unauthorized use of the project documents will give rise to the recovery of monetary losses and damages including attorney fees and costs for which the unauthorized user will be held liable.

Project documents describe the design intent of the work and are not a representation of as-built or existing
conditions. LPA is not responsible for any discrepancies between the project documents and the existing conditions. © LPA, Inc.
12" = 1'-0"

SANTA TERESA FIRE STATION
1330 WEST LUCHESSA AVENUEGILROY, CA 95020
GRIFFIN STRUCTURES, INC.

ELECTRICAL SINGLE

LINE DIAGRAMS
E5.00
33236
Checker

Page 254 of 256 ends

RESOLUTION NO. 2026-XX

A RESOLUTION OF THE CITY COUNCIL OF THE

CITY OF GILROY AMENDING THE BUDGET FOR
THE CITY OF GILROY FOR 2025-2026 AND 2026-2027

FISCAL YEARS AND AUTHORIZING AN INTERFUND

LOAN FROM THE GENERAL FUND AND THE

FACILITIES FUND
WHEREAS, the City Administrator prepared and submitted to the City Council a budget for the City of Gilroy for Fiscal Years 2025-2026 (FY26) and 2026-2027 (FY27), and the City Council carefully examined, considered, and adopted the same on June 2, 2025; and WHEREAS, City Staff has prepared and submitted to the City Council a proposed amendment to the budget for FY26 and FY27 for the City of Gilroy in the staff report dated June 29, 2026, to award the Design-Build Construction Services of the Santa Teresa Fire Station to Zumwalt Construction, Inc; and
WHEREAS, the City Council has determined that construction of the Santa Teresa Fire Station is a necessary capital improvement to improve fire service coverage and response times and has approved award of a design-build agreement for the project; and WHEREAS, the Santa Teresa Fire Station project is included in the City’s Capital Improvement Program as CIP Project No. 800290 in the Capital Projects Fund, and the total project cost exceeds the amount currently appropriated in FY26, thereby requiring a budget amendment and temporary cashflow financing to allow the project to proceed on schedule; and WHEREAS, under the Fourth Operating Memorandum to the Development Agreement – Glen Loma Ranch, dated October 21, 2024, Glen Loma Ranch (“GLR”) is obligated to provide a total of $7,200,000 toward the City’s fire station obligations, including a payment of $3,610,757 to the City upon recordation of a final map relative to Tentative Map 24-03; and WHEREAS, the City has already received and/or secured other components of GLR’s fire station funding obligation, including conveyance of the fire station parcel and earlier funding obligation steps, and the remaining $3,610,757 payment is anticipated to be received upon the occurrence of the applicable subdivision map milestone set forth in the Fourth Operating Memorandum; and
WHEREAS, in order to proceed with the Santa Teresa Fire Station project prior to receipt of the remaining GLR funding, the City Council finds it necessary and in the best interests of the City to authorize a temporary interfund loan to the Capital Projects Fund from available fund balances in the Facilities Fund and the General Fund, solely as interim financing for project cashflow needs; and
WHEREAS, City staff has determined that the Facilities Fund and the General Fund have

Page 255 of 256 ends

sufficient available fund balance to support a temporary interfund loan for this purpose, and that such loan is expected to be repaid from GLR fire station funding proceeds when received by the City pursuant to the Fourth Operating Memorandum; and
WHEREAS, the City Council desires to authorize a temporary interfund loan to the Capital Projects Fund in the total amount of $3,610,757, consisting of $1,500,000 from the Facilities Fund and $2,110,757 from the General Fund, to be repaid from future GLR fire station funding receipts or other legally available project revenues upon receipt thereof.

NOW, THEREFORE, BE IT RESOLVED THAT the City Council of City of Gilroy hereby increases the expenditure appropriations for FY26 in Capital Projects Fund by $11,942,555, decreases the expenditure appropriations for FY27 in Capital Projects Fund by $11,500,000, authorizes the transfer of $37,024 from Facilities Fund to the Capital Projects Fund, and authorizes a temporary interfund loan to the Capital Projects Fund for the Santa Teresa Fire Station project in the total amount of $3,610,757 comprised of $1,500,000 from the Facilities Fund and $2,110,757 from the General Fund.

PASSED AND ADOPTED this 29th day of June 2026 by the following roll call vote:

AYES: COUNCIL MEMBERS:

NOES: COUNCIL MEMBERS:

ABSTAIN: COUNCIL MEMBERS:

ABSENT: COUNCIL MEMBERS:

APPROVED:

Greg Bozzo, Mayor
ATTEST:
_______________________
Kim Mancera, City Clerk

Page 256 of 256 ends
← All documents from this meeting