07 52 00
SECTION F - Page 32
SPECIAL PROVISIONS
1. Fire Testing: Material shall be tested for a minimum of Class A fire rating. The system should pass the said tests without any rock, covering or emulsions thus facilitating maintenance and eliminating excess load on the roof. All modified bituminous sheet roofing systems must bear testing agency (Underwriters Lab, Warnock Hersey etc.) on package or container indicating that materials have been produced under testing agency’s classification and follow-up service.
2. Contractor shall obtain all local permits for the application of the roofing system. The contractor prior to the job must obtain necessary permits.
1.06 WARRANTY
A. Roofing Contractor: Upon completion of work, furnish a written five-year workmanship guarantee.
This warranty shall cover all leaks due to defective workmanship for a period of 5 years.
Manufacturer shall conduct an audit at no cost to owner within 3 years of project completion date.
All deficiencies identified in the report shall be fixed and brought up to specification at no cost to the owner.
B. Manufacturer: Manufacturer shall provide owner with a 30 year non-prorated Roofing System Guarantee. Warranty should cover all leaks caused by faulty workmanship or material. Warranty will be in effect on the date of substantial completion of the project.
1.07 SUBMITTALS
A. Pursuant to the provisions of the General Provisions. “Submittals” the Contractor shall submit the following:
1. Product specification sheet for each roofing component within the specified system. Data should substantiate that materials comply with the specifications.
2. Test results as outlined in Article 1.05.B above.
3. Final warranty per Article l.06.
4. Samples (3” x 5”) of each roofing component which is specified..
5. Shop Drawings: Provide manufacturers standard details and approved shop drawings for the roof system specified.
6. Installer shall provide written documentation from the manufacturer of their authorization to install the roof system, and eligibility to obtain the warranty specified in this section.
7. As part of the submittal package, contractor shall submit a letter from the manufacturer agreeing to perform the maintenance services identified in section 1.06 C at no cost to the owner.
1.08 PRODUCT DELIVERY, STORAGE AND HANDLING
A. Roofing material shall be delivered to the job-site in new, dry, unopened containers clearly showing catalog number, product description, manufacturer's name and location. Delivered quantities should be sufficient to assure continuous work.
B. Assure that materials are kept clean, and away from excessive heat and cold; do not remove labels or tear off protective covering until ready for application; store in an enclosed area where temperature is above 10 degrees C (50 degrees F) and below 32 degrees C (90 degrees F).
Material shall not be stored directly on the ground.
C. Do not double stack membrane. Maintain aisle space between stacks to facilitate fire suppression.
D. Do not overload structure with building materials.
07 52 00
SECTION F - Page 33
SPECIAL PROVISIONS
E. Strictly follow recommended storage instructions supplied by the manufacturer.
F. Store roll goods on end on pallets in a clean, dry, protected area. Take care to prevent damage to roll ends or edges. Do not double stack TPO systems or lay them on their side. Follow manufacturers’ instructions for storage and handling.
2 PART 2 - PRODUCTS
3 PART 3 - EXECUTION
3.01 EXISTING / GENERAL CONDITIONS
A. Contractor shall verify that surfaces are smooth, dry, sound, and free from any conditions effecting proper roofing applications. Prior to starting work, owner shall be advised of conditions needing correction. Work will not be started until other trade work required ahead of membrane application is completed. Contractor is responsible for all carpentry work such as wood nailers, wood curbs, wood expansion or contracting members, wood cants and similar items necessary for the completion of the work according to these specifications.
Removal of existing roof
1. The existing roofing membrane(s) and insulation shall be removed to the existing deck and shall include but not be limited to, all wall flashings, edge flashings, and all other items incorporated there in.
2. Remove only as much roofing as can be replaced with a completely new roofing system and made watertight the same day. Phase roofing application is not allowed.
3. All debris shall immediately be removed from the roof surface and deposited into trucks or containers through an enclosed trash chute. Removal of existing roofing materials should be performed in conjunction with the installation of the new roofing system. All exposed areas must immediately be covered and made watertight. No overnight stockpiling of debris on the roof shall be permitted.
4. Contractor shall clean all roof surfaces and is responsible for keeping the building and surrounding area neat and orderly.
5. Trash container or trucks shall be removed from the premises when they are full.
6. Clean the roof deck surfaces of all loose materials and other impediments detrimental to the application of the new roofing materials.
3.02 PROTECTION
A. Prior to any job shut-down, all seams laid in the preceding time period shall be checked for water tightness. Required precautions should be taken to leave the job in watertight condition. If moisture is present at any location contractor at no expense to the owner or manufacturer will replace all wet material.
B. All finished work of other trades that is damaged in the execution of work under this section shall be replaced or restored at the expense of the trade who caused the damage.
C. Ground storage and work shall be confined to the areas designated by the Owner as agreed upon at the pre-bid conference. Do not travel across landscaped areas without the Owner's approval.
3.03 SURFACE PREPARATION
A. Prior to installing the roofing material, remove from deck all debris, nails, sharp objects, dirt, moisture, petrochemical materials or projections that could in any way damage the systems.
Surface shall be prepared such that there is positive and workable drainage. Areas of the roof with ponding water should be corrected and the slope adjusted accordingly so as to prevent future
07 52 00
SECTION F - Page 34
SPECIAL PROVISIONS
standing water.
3.04 WORKMANSHIP
A. Contractors must be thoroughly skilled in the application of specified materials; with all workmanship done in such a manner as to fulfill the requirements of drawings and specifications.
Any specific directions furnished by manufacturer, and as published in the manufacturer's manual for modified bitumen roofing systems, regarding the application of roofing materials shall be strictly followed. All deviations from the manufacturer's published instructions shall be secured in writing on the manufacturer's letterhead approved by the "Manager of Technical Services".
B. Prior to applying TPO system the contractor and his foreman shall review the specifications and the manufacturer's technical manual with the manufacturer's technical representative to make certain all aspects of membrane application is understood. Application will proceed in strict accordance with specifications and detailed drawings and instructions in said technical manual.
No verbal/oral deviation will be accepted unless authorized on company's letterhead signed by the company's “Manager of Technical Services ".
C. Maintain constant supervision by a competent foreman.
D. Contractor must supervise installation of and be responsible for seeing that roof mechanical, electrical equipment, roof drains and other works are properly flashed. Make roof and flashing repairs as necessary; advise the Architect / owner in writing of all potential leaks as may be caused by other trades.
E. Install only as much roofing material as can be completed and covered with a cap membrane in one day. No section of the roof should be left exposed and unfinished. Phase roofing is not accepted.
F. Do not roll roofing equipment or stack materials on completed new roofing surfaces, without the adequate protection of a ½” plywood sheets.
G. Do not apply any roofing materials before sunrise, or at anytime when there are indications of moisture, (rain, mist, dew, frost or snow).
H. Insure that no heavy objects remain in one place on the portions of the new roofing membrane where the membrane has not yet set or the adhesive has not fully bonded the layers. .
I. Insure that all fish mouths are cut and patched (do not attempt to walk down the fish mouths).
Objects causing separation between reinforcing plies must be removed.
J. Every attempt shall be made to install flashings at openings, projections, and walls adjoining new roofing during all work periods. If circumstances do not allow this, these areas shall be made watertight at the end of each day or work period.
K. Aesthetic Considerations: An aesthetically pleasing overall appearance of the finished roof application is a standard requirement for this project. Make necessary preparations, utilize recommended application techniques, and apply the specified materials including granules, and exercise care in ensuring that the finished application is acceptable to the Owner.
3.05 INSULATION APPLICATION
A. Shall be applied in strict conformance with insulation manufacturer's specification and comply with NRCA and RIC- TIMA recommendations.
07 52 00
SECTION F - Page 35
SPECIAL PROVISIONS
Mechanically fasten the tapered polyisocyanurate board over the metal deck / Light Weight Concrete / Wood Deck with 16 fasteners per board per FM –I90 pattern (1.2 meter x 2.43 meter board (4 x 8 foot board). Fasteners shall be of sufficient length to penetrate the board and the metal deck and comply with FM I90 requirement. Use only fasteners with a minimum 3-inch (76 mm) stress plate when mechanically attaching insulation. Do not attach insulation with nails.
Adhere the pre primed cover board over the polyisocyanurate insulation in adhesive.
B. Install insulation boards with staggered board joints in one direction (unless taping joint).
C. Install insulation boards snug. Gaps between board joints shall not exceed 1/4 inch (6 mm). All gaps in excess of 1/4 inch (6 mm) shall be filled with like insulation material.
D. Wood nailers shall be 3-1/2 inches (89 mm) minimum width or 1 inch (25 mm) wider than metal flange. They shall be of equal thickness as the insulation with a minimum 1-inch (25 mm) thickness. All nailers shall be securely fastened to the deck.
E. Cant strips shall be installed at the intersection of the roof and all walls, parapets, curbs, or transitions approaching 90 degrees, to be flashed. They shall be approximately 4 inches (102 mm) in horizontal and 4 inches (102 mm) in vertical dimension. The face of the cant shall have an incline of not more than 45 degrees with the roof.
F. Do not install any more insulation than will be completely waterproofed each day.
3.06 COLD ADHESIVE
A. Smooth Ply & Cap Membrane Application: Apply roofing in accordance with roofing system manufacturer's specification and the following requirements. Apply the ply and cap sheet in cold adhesive allowing 3.5” side and 6” on end laps. End laps shall be staggered with a minimum spacing of 3”. Apply to produce a 1/8” -1/4” outflow of adhesive at all seams. Areas with less than 1/8” outflow will be checked with a trowel and resealed. Turn up 2” above can strip at all vertical surfaces. All layers shall be 100% adhered to each other and to the protection board or base. Areas of partial or loose adhesion shall be redone at contractor’s sole cost and expense.
The roofing membrane components shall immediately be applied after application of base sheet and/or insulation as a continuous operation.
1. Priming: All metal flanges (all jacks, edge metal, and lead drain flashings) and concrete and masonry surfaces shall be primed with an asphalt primer meeting ASTM D 41.
2. Membrane Adhesive Application: roller, squeegee or spray unit can be used for application of the membranes. Application shall be done in a smooth, even, continuous layer without breaks or voids. Pour the adhesive on the substrate and spread, using a serrated edged squeegee, applied at the rate of 1-1/2 gal per square (6 L/sm).
3. Fill all voids between the penetration and flashing collar with approved caulking.
4. Apply the adhesive so that the substrate is coated in a pattern slightly larger than the first sheet being applied.
5. End laps and selvage laps of the membrane being lapped shall be coated with adhesive so that a visible bead of adhesive appears. Roll all laps with a steel roller to ensure proper adhesion. Alternately, the end laps and side laps may be hot air welded. The hot-air welding method will provide a watertight lap immediately and may be preferable when inclement weather is threatening.
6. Allow 5 to 15 minutes for solvents to evaporate from the adhesive (i.e. tack time or open time) before embedding any sheets into newly applied adhesive. Tack times may vary based on ambient conditions.
07 52 00
SECTION F - Page 36
SPECIAL PROVISIONS
7. All rolls (both ply and cap) shall never be put down in full-length rolls (33 lineal feet).
They should be cut to the following lengths.
Slopes of ¼” up to 1 ½” 17-foot max
Slopes of 1 ½” to 2” 11-foot max
8. All material must be cut to specified lengths then relaxed or heated until the material lies completely flat before installation. (i.e. no wrinkles, buckles or rigid end strips)
9. Matching granules may be broadcast into the modified bitumen bleed out at seams while hot to enhance the finished appearance of the membrane.
10. All end laps shall be staggered a minimum of 18 inches (457 mm) so that no adjacent end laps coincide. If end laps fall in line or are not staggered the proper distance, a full width of membrane shall be installed over the end laps. End laps, flashing sheets and other seams formed over granule surfaces require pre-heating of the top surface of the underlying granule surface membrane to a point where the granules just begin to sink into, and the modified bitumen compound comes up through the granules to ensure proper seam construction and adhesion.
11. All laps shall be parallel or perpendicular to the slope of the roof such that the flow of water is not against the lap.
3.07 BASE FLASHINGS
A. Install all base flashings of roof wall junctures, projections and expansion point curbing per manufacturers specification. Backer sheet for flashing shall be a minimum of one layer of selfadhering smooth-surfaced polymer-modified bitumen sheet, smooth heat welded membrane covered with top surfacing. Base flashing cap sheet shall be applied via heat welding. Cold adhesive application of flashing is not allowed due to possibility of slippage.
B. Base flashing shall be fused in place so that it extends a minimum 6” onto surface of roof and a minimum of 4” above termination of roofing membrane on wall. When flashing has to be installed over a porous surface, apply asphalt primer at a rate of 1.9 - 2.8 liter / 10 sqm (1/2 to 3/4 gal. per 100 sq. ft) and allow to dry.
C. Apply pressure to the flashing membrane to obtain maximum contact to surface to which it is applied. There shall be no voids under the base flashing membrane. It is imperative that complete attachment be obtained to the roof surface, roofing membrane over cant, and the wall. A small bead of bitumen should be squeezed out at the edges.
D. Subsequent strips of base flashing shall be fused in place in the same fashion, overlapping preceding strip by 4”. Overlap shall be interply fused to preceding strip. Pressure shall be applied to surfaces to ensure adhesion.
E. The flashing must not remain open at the end of the workday.
F. The contractor shall thoroughly inspect the completed flashing system at the end of each day's work.
G. Mechanically fasten top edge base flashings with approved fasteners 4"-6” on center per manufacturer's specifications.
H. Install metal counter flashing as required.
3.08 FLASHINGS
07 52 00
SECTION F - Page 37
SPECIAL PROVISIONS
A. Install all base flashings of roof wall junctures, projections and expansion joints per manufacturers’ specification. Special care shall be taken to generously preheat the surface to which the flashing is being applied prior to heating the bottom of flashing membranes. Manufacturer's detailed flashing drawing's and application procedures shall be observed and strictly followed.
3.09 SEALANT
A. All edges of flashing exposed at gravel stops, waste stacks, pitch pans, vent stacks, etc., to be caulked with a smooth continuous bead of approved sealant.
3.10 INSPECTION OF COMPLETED SYSTEM
A. All cap membrane shall be carefully inspected by the Architect / owner for construction damage and imperfect heat fusion. Any holes or tears shall be patched with the appropriate cap membrane.
The patch must extend at least 4" in all directions from the edges of the tear or puncture. The final inspection of the roofing system shall be done prior to application of the coating. Any deficiency identified shall be repaired prior to applying the coating.
3.11 DEFICIENCY ADJUSTMENTS
A. Deficiencies identified by the Architect / owner during the final inspection shall be corrected within five (5) working days. The warranty will not be issued until the deficiencies are corrected.
3.12 CLEANING AND REPAIRING
A. The contractor shall be held fully responsible for cleaning, repairing, touch up or replacing (when directed) items or areas which have been soiled, discolored or damaged by the work of this section. Precaution shall be taken against splashing any material on to adjacent areas. The contractor shall immediately remove any trace of such splashes or spills.
3.13 WALKWAYS
A. Construct walkways prior to the application of coating by adhering it with approved adhesive.
Install walkways per architectural drawing. If no drawings are provided then install walkway around the perimeter of all rooftop equipment, at all door and stair landings and pathway between both.
B. Walkway sections shall be no longer than 3'x4' with a 2" inches minimum gap between each section to allow for drainage.
3.14 DEBRIS DISPOSAL
A. The contractor shall make his own arrangements for disposal of debris and waste material. All disposals will be done off site and at the contractor's expense. The owner assumes no responsibility for the disposal of any roofing material. Debris from project will be removed daily, and at no time allowed to block any thoroughfare. Premises shall be cleaned to the satisfaction of Architect / owner.
3.15 FIRE WATCH:
A. Fire watch shall be provided continuously during and for at least 2 hour after the last torch on the roof is extinguished. At least two 2-1/2 gallon containers of water and two 4A60BC extinguishers shall be available during the fire watch. When work is interrupted, or at the end of a section of roofing, and at end of each day's work, areas which had been subjected to torch applications shall
07 52 00
SECTION F - Page 38
SPECIAL PROVISIONS
be surveyed with an infra-red sensing device. Hot spots shall be cooled and re-surveyed. If a hot spot persists, the roof shall be cut open and any smoldering shall be extinguished before the foreman leaves the site.
END OF SECTION
07 62 00
SECTION F - Page 39
SPECIAL PROVISIONS
SECTION 07 62 00
SHEET METAL FLASHING AND TRIM
PART 1 - GENERAL
1.01 SECTION INCLUDES
A. Fabricated sheet metal items, including flashings, counter flashings, gutters, downspouts and other items indicated in Schedule. B. Sealants for joints within sheet metal fabrications.
1.02 RELATED REQUIREMENTS
A. Section 07 32 16 Concrete Roof Tiles
B. Section 07 52 00 Modified Bitumen Membrane
1.03 REFERENCE STANDARDS
A. ASTM A653/A653M—2017- Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or ZincIron Alloy-Coated (Galvanized) by the Hot-Dip Process.
B. ASTM B695—2004(2016) - Standard Specification for Coatings of Zinc Mechanically Deposited on Iron and Steel Strip for Building ConstructionCDA A4050 - Copper in Architecture - Handbook; current edition.
C. SMACNA (ASMM) - Architectural Sheet Metal Manual; 2012.
1.04 SUBMITTALS
A. See Administrative Requirements for submittal procedures.
B. Shop Drawings: Indicate material profile, jointing pattern, jointing details, fastening methods, flashings, terminations, and installation details.
C. Include major counter flashings, trim, fascia units and expansion joint systems, downspouts and scuppers.
D. Describe material profile, jointing pattern, jointing details, fastening methods and installation details.
E. Scaled manufacturer’s catalog data acceptable.
1.05 QUALITY ASSURANCE
A. Perform work in accordance with SMACNA (ASMM) and CDA A4050 requirements and standard details, except as otherwise indicated.
B. Fabricator and Installer Qualifications: Company specializing in sheet metal work with five years of documented experience in commercial and institutional type construction.
1.06 DELIVERY, STORAGE, AND HANDLING
A. Stack material to prevent twisting, bending, and abrasion, and to provide ventilation. Slope metal sheets to ensure drainage.
B. Package and protect materials during shipment to avoid dampness and staining. Uncrate and inspect materials for damage, dampness and staining upon delivery to the jobsite. Remove from the site and replace damaged materials that cannot be restored to like-new condition.
C. Store materials in dry, weather-tight, ventilated areas until immediately before installation. Stack performed and prefinished material to prevent twisting, bending or abrasion and to provide ventilation.
Prevent contact with materials during storage which may cause discoloration, staining or damage.
D. Handle sheet metal items to avoid damage to surfaces, edges and ends.
E. Prevent contact with materials that could cause discoloration or staining.
07 62 00
SECTION F - Page 40
SPECIAL PROVISIONS
PART 2 PRODUCTS
2.01 SHEET MATERIALS
A. Galvanized Steel: ASTM A653/A653M—2017; grade A, commercial quality, with G90/Z275 zinc coating; minimum 24 gage, (0.0239 inch) (0.61 mm) thick base metal or as indicated on the Drawings.
B. Lead Sheet: ASTM B749-03, 0.047 inch (1.19 mm) minimum thickness; UNS Number L51121.
1. Minimum 4 lbs/sf for split-lead (field soldered) jacks and drains, 2-1/2 lbs/sf for roof jacks.
2.02 GUTTER AND DOWNSPOUT FABRICATION
A. Seal metal joints.
2.03 ACCESSORIES
A. Provide accessory materials and other items essential to complete the sheet metal and trim installation, including sheet metal clips, straps, anchoring devices and similar accessory units as required for installation of the work, matching or compatible with material being installed, non-corrosive, size and gage required for performance minimums.
B. Fasteners: Rivets, nails, sheet metal screws, machine screws, self-tapping screws and stove bolts, of the types and size best adapted to the conditions of use.
1. Provide fasteners of the type specified or indicated.
2. Unless otherwise noted, fasteners shall be galvanized steel or stainless steel, with soft neoprene washers.
3. Open-end type rivets may be used for all applications except where watertight connections are required, in which case use closed-end type only.
4. Fasteners to Wood Substrate: Full threaded screws, galvanized when applied on the exterior, minimum No. 12 size, round head or flat head with neoprene washers as appropriate to surface applied.
5. Fasteners to Concrete, Masonry and Metal Substrates: Galvanized when applied on the exterior, expansion or wedge type as appropriate to surface applied, neoprene washers.
6. Comply with details on Drawings. C. Underlayment:
1. ASTM D412; Standard Test Method for Vulcanized Rubber and Thermoplastic Elastomers - Tension
2. ASTM D903; Standard Specification for Peel or Stripping Strength of Adhesive Bonds.
D. Primer: Coordinate primer with finish paint and coating, as applicable, to provide sound foundation for field-applied topcoats despite prolonged exposure during construction.
1. Shop Primer for Galvanized Steel, Exterior: SERIES 66 EPOXYLINE, Two-Part Epoxy Coating, by Tnemec.
2. Shop primer for Ferrous Metal at Concealed Exterior Locations and for Interior Locations: 90E-92, ETHYL SILICATE ZINC-RICH PRIMER, by Tnemec.
2.04 FABRICATION
A. Form sections true to shape, accurate in size, square, and free from distortion or defects.
B. Fabricate materials in accordance with the best trade practices and with all joints and corners accurately machined, filled and fitted and rigidly framed together and connected. C. Carefully match components to produce perfect continuity of line and design.
D. Make joints and connections in exterior face metal watertight, using approved sealing materials and methods of assembly.
E. Fit faces of metal in contact with hairline joints, except as otherwise indicate or require for expansion or fitting.
F. Conceal fastenings, unless otherwise indicated. Conceal required reinforcements within the finished assembly.
07 62 00
SECTION F - Page 41
SPECIAL PROVISIONS
G. Provide for expansion and contraction by providing expansion and contraction and building movement capability in the completed work, without over-stressing the materials, breaking connections, or producing wrinkles and distortion in finished surfaces.
1. Sealant Joints: Where movable, non-expansion type joints are indicated or required for proper performance of sheet metal work, form metal to provide for proper installation of onecomponent sealant.
2. Expansion Provisions: Where lapped or bayonet-type expansion provisions in sheet metal work cannot be used or would not be sufficiently waterproof and weatherproof form expansion joints of intermeshing hooked flanges, not less than 1 inch deep, filled with one component polyurethane sealant.
H. Finish sheet metal work water and weather-tight throughout.
I. Form pieces in longest possible lengths, true to shape, accurate in size, square and free from distortion or defects. Typically, provide sheet metal items in 8 to 10 ft lengths. Single pieces less than 8 ft long may be used to connect to factory-fabricated inside and outside corners and at ends of runs.
J. Miter and seam corners. Form exposed sheet metal work without excessive oil-canning, buckling or tool marks, true to line and levels indicated and with exposed edges folded back to form hems on underside 1/2 inch.
K. Form material with flat-lock seams. Sweat full of solder, except where installed to permit expansion and contraction. Lap flat-lock seams and lap seams where soldered, according to pitch, but in no case less than 3 inches. Make seams in direction of flow. Fill expansion joints with sealant.
1. Soldered flat lap seams not permitted.
L. Fabricate corners from one piece with minimum 18 inch long legs; solder for rigidity, seal with sealant.
M. Fabricate vertical faces with bottom edge formed outward 1/4 inch and hemmed to form drip.
PART 3 EXECUTION
3.01 EXAMINATION
A. Verify roof openings, curbs, pipes, sleeves, ducts, and vents through roof are solidly set, reglets in place, and nailing strips located.
B. Verify roofing termination and base flashings are in place, sealed, and secure.
3.02 INSTALLATION
A. Comply with details as indicated on the Drawings and included in the NRCA manual. When details or conditions are not indicated, comply with standard details and recommended practices in SMACNA and referenced industry standards. For proprietary products, comply with manufacturer’s installation instructions and recommendations.
B. Produce lines, profiles, rises and angles accurate, sharp and true. Make corners square, surfaces true and straight in planes.
C. Exposed surfaces shall be free from visible wave, warp, buckle or tool marks. Fold back exposed edges neatly to form a 1/2 inch hem on the concealed side. Make sheet metal exposed to the weather watertight with provisions for expansion and contraction.
D. Secure flashings in place using concealed fasteners. Provide compatible washers to protect surface of sheet metal and to provide a watertight connection.
1. Restrict screw and nail applications to sheet metal having a maximum width of 18 inches.
2. Space fasteners evenly not over 3 inches O.C. and approximately 1/2 inch from edges.
3. Exposed fasteners in locations open to public view not permitted.
E. Install sheet metal flashing and trim with laps, joints and seams that will be permanently watertight and weatherproof. Provide lapped and sealed joints only where indicated and where approved by the Architect.
F. Apply plastic cement compound between metal flashings and felt flashings.
07 62 00
SECTION F - Page 42
SPECIAL PROVISIONS
G. Fit flashings tight in place. Make corners square, surfaces true and straight in planes, and lines accurate to profiles.
H. Seal metal joints watertight.
I. Solder metal joints for full metal surface contact.
1. Clean and flux metals in seams before soldering.
2. Pre-tin edges of sheet metal before soldering.
3. Solder immediately after application of flux. Slowly solder with well heated soldering irons so as to thoroughly heat the seams and completely sweat the solder through the full width of the seam.
4. After soldering, wash metal clean with neutralizing solution and rinse with water. J.
Secure all sheet metal components in place using concealed fasteners.
K. Seal metal joints watertight. Apply plastic cement compound between metal flashings and felt flashings.
L. Cleats and Starter Strips:
1. Provide cleats for sheet metal where indicated and also where sheet metal is 18 inches and over in width.
2. Unless continuous cleat is indicated, space cleats evenly not over 12 inches oc, unless otherwise indicated.
3. Unless otherwise indicated, cleats shall be not less than 2 inches wide by 3 inches long and of the same material and thickness as the sheet metal being installed.
4. Secure one end of cleat with two fasteners, with cleat folded back over the fastener head.
Lock other end into seam.
5. Pre-tin cleats for soldered seams.
M. Flanges: Bed flanges of sheet metal fabrications in a thick coat of bituminous roofing cement where required for waterproof performance. N. Seams:
1. Provide seams with uniform width and height, with no solder showing on the face.
2. Flat-lock seams. Finish not less than 3/4 inch wide.
3. Lap seams. Overlap seams, not soldered, shall be not less than 3 inches wide.
4. Loose-lock expansion seams shall be not less than 3 inches wide. Provide minimum 1 inch movement within the joint. Completely fill the joints with one-component polyurethane sealant applied in a not less than 1/8 inch bed.
5. Standing seams shall be not less than 1 inch high, double locked without solder.
6. Flat seams shall be fabricated in the direction of the flow.
3.03 EXPANSION CONTROL
A. Provide for expansion and contraction of sheet metal as recommended in SMACNA.
B. Sheet metal shall accommodate thermal expansion and contraction resulting from an ambient temperature differential of 120 degrees F, which may result in a metal surface temperature range of 180 degrees F, without causing buckling excessive stresses on structural elements or fasteners, stresses on glazing, failure of seals, reduction of performance or other detrimental effects on appearance and performance.
C. Provide expansion and contraction control joints at not more than 40 ft intervals typically.
Provide joints at 10 ft O.C. for copings, gravel stops and other roof edge terminations. Space joints evenly.
D. Where the distance between the last expansion joint and the end of the continuous run is more than half the required interval, provide an additional joint.
E. Attach expansion joint units to curb nailers with appropriate fasteners, at maximum spacing of 6 inches oc. Fabricate seams at joints between units with minimum 3 inch overlap, to form a continuous, waterproof system.
07 62 00
SECTION F - Page 43
SPECIAL PROVISIONS
3.04 DISSIMILAR MATERIALS
A. Coat surfaces in contact with mortar, concrete or other cementitious materials with alkaliresistant bituminous coating.
B. Apply 7.5 mil minimum dry film thick coating of bituminous paint to each contacting face of dissimilar metals, for net 15 mil minimum thickness of coating.
C. Paint surfaces of wood or other absorptive materials that may become repeatedly wet and in contact with metal with heavy application of bituminous coating.
3.05 FLASHINGS AND COUNTERFLASHINGS
A. Fit flashings tight in place. Secure flashings in place using concealed fasteners only.
B. Install reglets true to lines and levels, located minimum 8 inches above cant at high point of roof decks. Install reglets to receive counterflashing in manner and by methods indicated. Seal top of surface-applied reglets with one-component polyurethane sealant.
C. Install counterflashing in reglets to form tight fit, either by snap-in seal arrangement or by securing in place with lead wedges spaced 18 inches oc maximum. Pack remaining spaces with lead wool.
D. Insert counterflashing in reglets, extending down vertical surfaces over upturned vertical leg of base flashings not less than 3 inches.
E. Form counter flashings to required shapes before installation.
F. Lengths of metal counter flashings shall not exceed 10 ft. Where stepped counter flashings are required, counterflashing may be installed in short lengths of may be of preformed, one-piece type.
G. Provide factory or shop formed corners not less than 12 inches from the angle.
H. Provide end laps in counter flashings not less than 3 inches and make laps weathertight with sealant.
I. Install edge of counter flashings built into masonry or concrete walls not less than 2 inches into wall.
J. Fold exposed edges of counterflashing 1/2 inch. Install material to provide a spring action against base flashing.
3.06 ROOF PENETRATIONS
A. Provide metal flashing for all pipes, ducts and conduits projecting through the roof surface and for equipment supports, and similar items supported by or attached to the roof deck as required for a watertight assembly of new roofing materials.
B. Vent Pipe Flashing:
1. Construct vent pipe flashing sleeve of 2-1/2 lb lead with minimum 4 inch wide flange.
2. Prior to pipe flashing installation, install roofing plies up to the pipe penetration and cut neatly around the opening.
3. Prime pipe flashing flange on both sides with specified primer.
4. Flanged metal shall be primed, allowed to dry, installed on top of finished plies, in a bed of mastic and nailed 4 inches O.C. staggered and stripped-in with two reinforcing felts (the first 4 inches beyond flange, the second 4 inches beyond first) prior to application of surfacing.
5. Mop over to ensure embedment of top surfacing.
6. Crimp top of lead at least one inch into pipe.
7. Provide draw band and sealant at condensate lines, electrical, gas and similar penetrations.
3.07 CLEANING AND PREPARATION FOR FIELD PAINTING
A. Neutralize excess flux with 5 to 10 percent soda solution and rinse.
B. Repair or replace damaged and deformed sheet metal.
07 62 00
SECTION F - Page 44
SPECIAL PROVISIONS
C. Wash down exposed surfaces and remove stains, scrap and debris such that sheet metal is ready to receive field painting and related work.
D. Remove soiling, dust, contamination from steel wool and drilling residue and other scrap and debris.
E. Scrub surfaces with detergent solution as necessary to remove grease and oil films, handling marks and stains.
3.08 FIELD PAINTING
A. Field-paint exposed sheet metal for corrosion resistance and decorative purposes.
B. Paint all exposed sheet metal under provisions of Special Coatings.
3.09 SCHEDULE
A. Downspouts:
1. Exposed Type: Rectangular shape and size as indicated on Drawings, gage as indicated on the Drawings, or if not indicated, minimum 20 gage galvanized sheet steel with brackets, reinforcing and internal diverters.
2. Fabricate downspouts in approximately 10 ft lengths.
3. Provide end joints telescoped not less than 1/2 inch and with flat lock seams.
4. Provide downspout terminations at grade. Coordinate installation to ensure that water is directed onto concrete paving or concrete splash block. Provide connection to underground storm drain system where indicated on Drawings.
B. Reglets and Flashings:
1. Provide formed metal spring-lock type reglets with snap-in metal counterflashing, factory fabricated, with a minimum opening of 1/4 inch and a depth of 1-1/4 inches. Reglets shall be surface-mounted, unless shown otherwise on Drawings.
2. Material: Minimum 24 gage galvanized steel.
3. End Laps: Factory-formed, 1 inch at reglets and 3 inches at flashings.
4. Corners: Provide built-up mitered corner pieces for internal and external angles.
5. Wind Clips: Provide sheet metal clips to be secured to wall prior to installing flashing in reglet and to be bent up over bottom edge of flashing.
6. Provide slotted mounting holes spaced 16 inches O.C. for fastening reglet to vertical substrate.
7. Corners: Factory-manufactured, mitered inside and outside corners.
8. Splices: Factory-manufactured, integral component of reglet and flashing system.
C. Copings and Cap Flashings
1. Fabricate from minimum 20 gage galvanized steel. Provide all coping and caps of the types and shapes indicated on Drawings.
2. Build-in integral expansion joints, allowing for movement of the metal without resulting in distortion of coping or leaks of any kind. Work shall be watertight.
D. Gutters:
1. Fabricate from minimum 24 gage galvanized sheet metal.
2. Install an expansion joint every 30 linear feet of gutter. Install cover plates over expansion joints.
3. Fabricate gutter without longitudinal seams.
4. Install cradles of 1/4 inch by 1-1/2 inch galvanized steel at 36 inches oc.
5. Gutters shall rest in cradles but shall not be mechanically fastened, to allow for expansion and contraction.
E. Scuppers:
1. Fabricate from 20 gage galvanized sheet steel.
2. Apply Type 1 sealant, as specified in Section 07900, in all crevices.
F. Downspouts and Strainers:
07 62 00
SECTION F - Page 45
SPECIAL PROVISIONS
1. Fabricate from 24 gage galvanized steel.
2. Strainers shall be 10 gage galvanized steel wire basket type.
3. Provide all anchor clips and straps as required for installation.
4. Install wire basket strainer in all downspouts at gutter level.
G. Drips:
1. Fabricate from 20 gage galvanized sheet
steel at heads of all doors in exterior walls where no
roof or overhead protection occurs.
2. Extend drips minimum 2 inches beyond
jambs.
H. Pitch Pans:
1. Construct pitch pans of minimum 24 gage galvanized sheet metal, 4 inches high, with minimum 4 inch continuous flange.
2. Prime all surfaces with specified primer, including surfaces of pipe or structural element penetrating the roof system.
3. Flanged metal shall be primed, allowed to dry, installed on top of finished plies, in a bed of mastic and nailed 4 inches O.C. staggered and stripped-in with two reinforcing felts (the first 4 inches beyond flange, the second 4 inches beyond first) prior to application of surfacing.
4. Apply membrane system.
5. Fill pitch pan 2/3 depth with non-shrink grout. Fill top 1/3 depth with specified plastic cement, sloped to drain.
H. Miscellaneous:
1. Provide miscellaneous flashings as shown on the Drawings and required to complete sheet metal flashing and trim work under this Section.
2. Provide shop drawings indicating details for approval.
3. Materials: Not less than 24 gage thickness, and as required to produce firm, solid, structurally sound elements, capable of withstanding wear and external forces normally associated with component or assembly.
END OF SECTION
SECTION G - Page 1
APPENDIX
SECTION 09 90 00
INTERIOR, EXTERIOR AND HIGH-PERFORMANCE PAINTS AND COATINGS PART 2 GENERAL
2.1 SECTION INCLUDES
A. Interior paint and coating systems (LEED-V4 and V4.1) including surface preparation.
B. Interior paint and coating commercial systems including surface preparation.
C. Interior paint and coating healthcare systems including surface preparation.
D. Interior high-performance paint and coatings systems including surface preparation.
E. Exterior high-performance paint and coatings systems including surface preparation.
F. Exterior paint and coating systems including surface preparation.
2.2 RELATED SECTIONS
A. Section 03 30 00 - Cast-in-Place Concrete.
B. Section 04 20 00 - Unit Masonry: Concrete Masonry Units (CMU) and brick.
C. Section 05 12 16 - Fabricated Fireproofed Steel Columns.
D. Section 05 50 00 - Metal Fabrications.
E. Section 06 20 00 - Finish Carpentry.
F. Section 06 40 00 - Architectural Woodwork.
G. Section 08 11 13.16 - Custom Hollow Metal Doors and Frames.
H. Section 09 21 16.23 - Gypsum Board Shaft Wall Assemblies.
I. Section 23 05 00 - Common Work Results for HVAC.
J. Section 26 05 00 - Common Work Results for Electrical.
2.3 REFERENCES
A. Steel Structures Painting Council (SSPC):
1. SSPC-SP 1 - Solvent Cleaning.
2. SSPC-SP 2 - Hand Tool Cleaning.
3. SSPC-SP 3 - Power Tool Cleaning.
4. SSPC-SP5/NACE No. 1, White Metal Blast Cleaning.
5. SSPC-SP6/NACE No. 3, Commercial Blast Cleaning.
6. SSPC-SP7/NACE No. 4, Brush-Off Blast Cleaning.
7. SSPC-SP10/NACE No. 2, Near-White Blast Cleaning.
SECTION G - Page 2
APPENDIX
8. SSPC-SP11, Power Tool Cleaning to Bare Metal.
9. SSPC-SP12/NACE No. 5, Surface Preparation and Cleaning of Metals by Waterjetting Prior to Recoating.
10. SSPC-SP 13 / NACE No. 6 Surface Preparation for Concrete.
B. Material Safety Data Sheets / Environmental Data Sheets: Per manufacturer's MSDS/EDS for specific VOCs (calculated per 40 CFR 59.406). VOCs may vary by base and sheen.
C. California Department of Public Health (CDPH):
1. CDPH v1.1-2010 and V1.2-2017
D. LEEDv4 EQ Credit: Indoor Environmental Quality-Low Emitting Materials
2.4 SUBMITTALS
A. Submit under provisions of Section 01 30 00 - Administrative Requirements.
B. Product Data: For each paint system indicated, including.
1. Product characteristics.
2. Surface preparation instructions and recommendations.
3. Primer requirements and finish specification.
4. Storage and handling requirements and recommendations.
5. Application methods.
6. Cautions for storage, handling and installation.
C. Selection Samples: Submit a complete set of color chips that represent the full range of manufacturer's products, colors and sheens available.
D. Verification Samples: For each finish product specified, submit samples that represent actual product, color, and sheen.
E. Coating Maintenance Manual: Upon conclusion of project, the Contractor or paint manufacturer/supplier shall furnish a coating maintenance manual, such as SherwinWilliams, "Custodian Project Color and Product Information" report or equal. Manual shall include an Area Summary with finish schedule, Area Detail designating where each product/color/finish was used, product data pages, Material Safety Data Sheets, care and cleaning instructions, touch-up procedures, and color samples of each color and finish used. "
F. Only submit complying products based on project requirements (i.e. LEED). One must also comply with the regulations regarding VOCs (CARB, OTC, SCAQMD, LADCO). To ensure compliance with district regulations and other rules, businesses that perform coating activities should contact the local district in each area where the coating will be used.
G. USGBC LEED V4 Submittals:
1. MRc2 Environmental Product Declaration Product Language: Products shall be selected with a preference to products that have product-specific environmental product declaration documentation.
2. EQc2 Low Emitting Materials: The VOC content of all adhesives, sealants, paints and coatings in this Section shall not exceed the VOC limits established in Division 01 Sustainable Design sections.
2.5 QUALITY ASSURANCE
SECTION G - Page 3
APPENDIX
A. Installer Qualifications: A firm or individual experienced in applying paints and coatings similar in material, design, and extent to those indicated for this Project, whose work has resulted in applications with a record of successful in-service performance.
B. Paint exposed surfaces. If a color of finish, or a surface is not specifically mentioned, Architect will select from standard products, colors and sheens available.
C. Do not paint prefinished items, concealed surfaces, finished metal surfaces, operating parts, and labels unless indicated.
D. Mock-Up: Provide a mock-up for evaluation of surface preparation techniques and application workmanship.
1. Finish surfaces for verification of products, colors and sheens.
2. Finish area designated by Architect.
3. Provide samples that designate primer and finish coats.
4. Compatibility and Adhesion: Check after one week of drying and curing by testing in accordance with ASTM D3359; Adhesion by tape test. If coating system is incompatible, additional surface preparation up to and including complete removal may be required.
5. Do not proceed with remaining work until the Architect approves the mock-up.
2.6 DELIVERY, STORAGE, AND HANDLING
A. Delivery: Deliver manufacturer's unopened containers to the work site. Packaging shall bear the manufacturer's name, label, and the following list of information.
1. Product name, and type (description).
2. Application and use instructions.
3. Surface preparation.
4. VOC content.
5. Environmental handling.
6. Batch date.
7. Color number.
B. Storage: Store and dispose of solvent-based materials, and materials used with solvent-based materials, in accordance with requirements of local authorities having jurisdiction.
C. Store materials in an area that is within the acceptable temperature range, per manufacturer's instructions. Protect from freezing.
D. Handling: Maintain a clean, dry storage area, to prevent contamination or damage to the coatings.
2.7 PROJECT CONDITIONS
A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.
2.8 EXTRA MATERIALS
A. Furnish extra paint materials from the same production run as the materials applied and in the quantities described below. Package with protective covering for storage and identify with labels describing contents. Deliver extra materials to Owner.
SECTION G - Page 4
APPENDIX
B. Furnish Owner with an additional one percent of each material and color, but not less than 1 gal (3.8 l) or 1 case, as appropriate.
PART 3 PRODUCTS
3.1 MANUFACTURERS
A. Acceptable Manufacturer: Sherwin-Williams, which is located at: 101 Prospect Ave.; Cleveland, OH 44115; ASD Toll Free Tel: 800-524-5979; Tel: 216-566-2000; Fax: 440-826- 1989; Email: request [email protected]; Web:www.swspecs.com.
B. Substitutions: Not permitted.
C. Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.
3.2 APPLICATIONS/SCOPE
A. Interior Paint and Coating Systems: LEED v4 EQ Credit: Indoor Environmental QualityLow Emitting Materials.
1. Concrete: Poured, precast, tilt-up, cast-in-place, cement board, plaster.
2. Concrete: Non-vehicular floors.
3. Masonry: Concrete masonry units, including split-face, scored, and smooth block.
4. Metal: Aluminum, galvanized steel.
5. Metal: Structural steel, joists, trusses, beams, partitions and similar items.
6. Wood: Walls, ceilings, doors, trim and similar items.
7. Drywall: Drywall board, Gypsum board.
B. Interior Paint and Coating Commercial Systems:
1. Concrete: Poured, precast, tilt-up, cast-in-place, cement board, plaster.
2. Concrete: Non-vehicular floors.
3. Masonry: Concrete masonry units, including split-face, scored, and smooth block.
4. Metal: Aluminum, galvanized steel.
5. Metal: Structural steel, joists, trusses, beams, partitions and similar items.
6. Wood: Walls, ceilings, doors, trim and similar items.
7. Drywall: Drywall board, Gypsum board.
C. Interior Paint and Coating Healthcare Systems:
1. Concrete: Poured, precast, tilt-up, cast-in-place, cement board, plaster.
2. Concrete: Non-vehicular floors.
3. Masonry: Concrete masonry units, including split-face, scored, and smooth block.
4. Metal: Aluminum, galvanized steel.
5. Metal: Structural steel, joists, trusses, beams, partitions and similar items.
6. Wood: Walls, ceilings, doors, trim and similar items.
7. Drywall: Drywall board, Gypsum board.
D. High Performance Interior Paint and Coating Systems:
1. Concrete: Poured, precast, tilt-up, cast-in-place, cement board, plaster.
2. Concrete: Exposed ceilings.
3. Masonry: Concrete masonry units, including split-face, scored, and smooth block.
4. Metal: Aluminum, galvanized steel.
5. Metal: Structural steel, joists, trusses, beams, partitions and similar items.
6. Wood: Walls, ceilings, doors, trim and similar items.
SECTION G - Page 5
APPENDIX
7. Drywall: Drywall board, Gypsum board.
E. High Performance Exterior Paint and Coating Systems:
1. Concrete: Cementitious siding, flexboard, transite, and shingles; non-roof.
2. Masonry: Concrete masonry units, cinder or concrete block.
3. Metal: Aluminum, galvanized steel.
4. Metal: Miscellaneous iron, ornamental iron, ferrous metal.
5. Wood: Siding, trim, shutters, sash, and miscellaneous hardboard.
F. Exterior Paint and Coating Systems:
1. Concrete: Cementitious siding, flexboard, transite, and shingles; non-roof.
2. Masonry: Concrete masonry units, cinder or concrete block.
3. Concrete: Non-vehicular concrete floors, patios, porches, steps and platforms.
4. Metal: Aluminum, galvanized steel.
5. Metal: Miscellaneous iron, ornamental iron, ferrous metal.
6. Wood: Non-vehicular floors, and platforms.
7. Wood: Siding, trim, shutters, sash, and miscellaneous hardboard.
8. Architectural PVC, plastic, fiberglass.
9. Drywall: Gypsum board, and exterior drywall.
10. Vinyl: Siding, EIFS, synthetic stucco.
3.3 PAINT MATERlALS - GENERAL
A. Paints and Coatings:
1. Unless otherwise indicated, provide factory-mixed coatings. When required, mix coatings to correct consistency in accordance with manufacturer's instructions before application. Do not reduce, thin, or dilute coatings or add materials to coatings unless such procedure is specifically described in manufacturer's product instructions.
2. For opaque finishes, tint each coat including primer coat and intermediate coats, onehalf shade lighter than succeeding coat, with final finish coat as base color. Or follow manufactures product instructions for optimal color conformance.
B. Primers: Where the manufacturer offers options on primers for a particular substrate, use primer categorized as "best" by the manufacturer.
C. Coating Application Accessories: Provide all primers, sealers, cleaning agents, cleaning cloths, sanding materials, and clean-up materials required, per manufacturer's specifications.
D. Color: Refer to Finish Schedule for paint colors, and as selected.
E. LEED Requirements: LEED V4 and V4.1 EQ Credit: Indoor Environmental Quality-Low Emitting Materials.
3.4 INTERIOR PAINT AND COATING SYSTEMS (LEED-V4 AND V4.1 NC/CI/CS
COMPLIANT)
A. Concrete: Walls and Ceilings, Poured Concrete, Precast Concrete, Unglazed Brick, Cement Board, Tilt-Up, Cast-In-Place including Plaster Walls and Ceilings.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series.
SECTION G - Page 6
APPENDIX
3) 3rd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series (6.0 mils wet, 2.5 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series (4 mils wet, 1.5 mils dry per coat).
c. Semi-Gloss Finish: High Performance (HP) Upgrade.
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series (4 mils wet, 1.6 mils dry per coat).
d. Semi-Gloss Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Semi-Gloss, A88 Series.
3) 3rd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Semi-Gloss, A88 Series (4 mils wet, 1.7 mils dry per coat.). e. Eg-Shel / Satin Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series (4 mils wet, 1.7 mils dry per coat).
f. Eg-Shel / Satin Finish: High Performance (HP) Upgrade. 1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series (4 mils wet, 1.7 mils dry per coat).
g. Eg-Shel / Satin Finish: Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Satin, A87 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Satin, A87 Series. (4 mils wet, 1.6 mils dry per coat). h. Low Sheen Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Eg-Shel, B41- 2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Eg-Shel, B41- 2600 Series (4 mils wet, 1.6 mils dry per coat).
i. Low Sheen Finish: High Performance (HP) Upgrade.
SECTION G - Page 7
APPENDIX
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Eg-Shel, B41-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Eg-Shel, B41-1950 Series (4 mils wet, 1.6 mils dry per coat).
j. Flat Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-12600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-12600 Series (4 mils wet, 1.6 mils dry per coat).
k. Flat Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Flat, A86 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Flat, A86 Series (4 mils wet, 1.8 mils dry per coat).
2. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5 mils wet, 2.0 mils dry per coat).
B. Concrete: Ceilings, Poured Concrete, Precast Concrete, Cement Board, Cast-In-Place including Plaster Ceilings.
1. Dryfall Waterborne Topcoats:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series. 2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series
SECTION G - Page 8
APPENDIX
(5.8 mils wet, 2.3 mils dry per coat).
b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series (6 mils wet, 1.9 mils dry per coat).
c. Flat Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series (6 mils wet, 1.7 mils dry per coat).
C. Masonry; CMU: - Concrete, Split Face, Scored, Smooth, High Density, Low Density, Fluted.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series (6.0 mils wet, 2.5 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series (4 mils wet, 1.5 mils dry per coat).
c. Semi-Gloss Finish: High Performance (HP) Upgrade.
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series (4 mils wet, 1.6 mils dry per coat).
d. Semi-Gloss Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Semi-Gloss, A88 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Semi-Gloss, A88 Series (4 mils wet, 1.7 mils dry per coat). e. Eg-Shel / Satin Finish:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series (4 mils wet, 1.7 mils dry per coat).
f. Eg-Shel / Satin Finish: High Performance (HP) Upgrade. 1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
SECTION G - Page 9
APPENDIX
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series (4 mils wet, 1.7 mils dry per coat).
g. Eg-Shel / Satin Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Satin A87 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Satin A87 Series (4 mils wet, 1.6 mils dry per coat).
h. Low Sheen Finish:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Eg-Shel, B41- 2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Eg-Shel, B41- 2600 Series (4 mils wet, 1.6 mils dry per coat).
i. Low Sheen Finish: High Performance (HP) Upgrade.
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Eg-Shel, B41-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Eg-Shel, B41-1950 Series (4 mils wet, 1.6 mils dry per coat).
j. Flat Finish:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W ProMar 200 Zero VOC Flat, B30-12600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Flat, B30-12600 Series (4 mils wet, 1.6 mils dry per coat).
k. Flat Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Flat A86 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Flat A86 Series (4 mils wet, 1.8 mils dry per coat).
2. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
SECTION G - Page 10
APPENDIX
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4.0 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Heavy Duty Block Filler, B42W150 (75- 125 sq ft/gal).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
D. Metal: Aluminum and Galvanized.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series (2.0-4.0 mils dry per coat).
b. Semi-Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series (2.0-
4.0 mils dry per coat).
c. Eg-Shel / Satin Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series (2.0-4.0 mils dry per coat).
2. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46-
SECTION G - Page 11
APPENDIX
Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
3. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Waterbased Acrolon 100, B65-720 series. 3) 3rd Coat: S-W Waterbased Acrolon 100, B65-720 series (4.0 mils wet,
2.0 mils dry per coat).
b. Gloss Finish: Single Component
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6-12 mils wet, 1.9-3.8 mils dry per coat).
E. Metal: Galvanized; Ceilings, Duct work.
1. Dryfall Waterborne Topcoats:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series. 2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series (5.8 mils wet, 2.3 mils dry per coat).
b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series (6.0 mils wet, 1.9 mils dry per coat).
c. Flat Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series (6.0 mils wet, 1.7 mils dry per coat).
F. Metal: Structural Steel Columns, Joists, Trusses, Beams, Miscellaneous and Ornamental Iron, Structural Iron, and Ferrous Metal.
1. Latex Systems:
a. Gloss Finish High Performance:
SECTION G - Page 12
APPENDIX
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series (2.0-4.0.0 mils dry per coat).
b. Semi-Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series (2.0-
4.0 mils dry per coat).
c. Eg-Shel / Satin Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series (2.0-4.0 mils dry per coat).
2. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
3. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Waterbased Acrolon 100, B65-720 Series.
SECTION G - Page 13
APPENDIX
3) 3rd Coat: S-W Waterbased Acrolon 100, B65-720 Series (4.0 mils wet, 2 mils dry per coat).
b. Gloss Finish: Single Component
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6-12 mils wet, 1.9-3.8 mils dry per coat).
4. Dryfall Waterborne Topcoat:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series.
3) 3rd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series (5.8 mils wet, 2.3 mils dry per coat).
b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series.
3) 3rd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series (6.0 mils wet, 1.9 mils dry per coat).
c. Flat Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series.
3) 3rd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series (6.0 mils wet, 1.7 mils dry per coat).
G. Wood: Walls, Ceilings, Doors, and Trim.
1. Latex Systems:
a. Gloss Finish:
1) 1st Coat: S-W Multi-Purpose Int./Ext Primer/Sealer, B51-450 (4 mils wet, 1.44 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series (2.0-4.0 mils dry per coat).
b. Semi - Gloss Finish:
1) 1st Coat: S-W Multi-Purpose Int./Ext Primer/Sealer, B51-450 (4 mils wet, 1.44 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series (2.0-
4.0 mils dry per coat).
c. Eg-Shel / Satin Finish:
1) 1st Coat: S-W Multi-Purpose Int./Ext Primer/Sealer, B51-450 (4 mils wet, 1.44 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series (2.0-4.0
SECTION G - Page 14
APPENDIX
mils dry per coat).
d. Flat Finish:
1) 1st Coat: S-W Multi-Purpose Int./Ext Primer/Sealer, B51-450 (4 mils wet, 1.44 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-2600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-2600 Series (4 mils wet, 1.6 mils dry per coat).
H. Drywall: Walls, Ceilings, Gypsum Board and similar items.
1. Latex Systems:
a. Semi-Gloss Finish:
1) 1st Coat: S-W ProMar200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series (4 mils wet, 1.5 mils dry per coat).
b. Semi-Gloss Finish: High Performance (HP) Upgrade.
1) 1st Coat: S-W ProMar200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series (4 mils wet, 1.6 mils dry per coat).
c. Semi-Gloss Finish Formaldehyde and Odor Reducing:
1) 1st Coat: ProMar 200 Zero VOC Interior Latex Primer, B28W2600. (4 mils wet, 1.5 mils dry per coat).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Semi-Gloss A88 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Semi-Gloss A88 Series (4 mils wet, 1.7 mils dry per coat). d. Eg-Shel / Satin Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series (4 mils wet, 1.7 mils dry per coat).
e. Eg-Shel / Satin Finish: High Performance (HP) Upgrade. 1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series (4 mils wet, 1.7 mils dry per coat).
f. Eg-Shel / Satin Finish Formaldehyde and Odor Reducing:
1) 1st Coat: ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry per coat).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Satin A87 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Satin A87 Series.(4 mils wet, 1.6 mils dry per coat).
SECTION G - Page 15
APPENDIX
g. Low Sheen Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Egshel, B41- 2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Egshel, B41- 2600 Series (4 mils wet, 1.6 mils dry per coat).
h. Low Sheen Finish: High Performance (HP) Upgrade.
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Egshel, B41-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Egshel, B41-1950 Series (4 mils wet, 1.6 mils dry per coat).
i. Flat Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-12600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-12600 Series (4 mils wet, 1.6 mils dry per coat).
j. Flat Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry per coat).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Flat, A86 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Flat, A86 Series (4 mils wet, 1.8 mils dry per coat).
2. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600
SECTION G - Page 16
APPENDIX
(4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
I. Concrete: Floors, non-vehicular.
1. Epoxy Systems:
a. Gloss Finish:
1) 1st Coat: S-W ArmorSeal 8100 B70-8100 Series.
2) 2nd Coat: S-W ArmorSeal 8100 B70-8100 Series (5-12 mils wet, 2-5 mils dry).
b. Satin Finish:
1) 1st Coat: S-W ArmorSeal 8100 B70-8160 Series.
2) 2nd Coat: S-W ArmorSeal 8100 B70-8160 Series (5-12 mils wet, 2-5 mils dry).
3.5 INTERIOR PAINT AND COATING COMMERCIAL SYSTEMS
A. Concrete: Walls and Ceilings, Poured Concrete, Precast Concrete, Unglazed Brick, Cement Board, Tilt-Up, Cast-In-Place including Plaster Walls and Ceilings.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series (6.0 mils wet, 2.5 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series (4 mils wet, 1.5 mils dry per coat).
c. Semi-Gloss Finish: High Performance (HP) Upgrade.
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series (4 mils wet, 1.6 mils dry per coat).
d. Semi- Gloss Scuff Resistant Waterbase Enamel.
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry)
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series:
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series (4 mils wet, 1.2 mils dry per coat). e. Eg-Shel / Satin Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50
SECTION G - Page 17
APPENDIX
(8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series (4 mils wet, 1.7 mils dry per coat).
f. Eg-Shel / Satin Finish: High Performance (HP) Upgrade. 1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series (4 mils wet, 1.7 mils dry per coat).
g. Eg-Shel/Satin Scuff Resistant Waterbase Enamel.
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series 3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series (4 mils wet, 1.2 mils dry per coat). h. Low Sheen Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Eg-Shel, B41- 2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Eg-Shel, B41- 2600 Series (4 mils wet, 1.6 mils dry per coat).
i. Low Sheen Finish: High Performance (HP) Upgrade.
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Eg-Shel, B41-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Eg-Shel, B41-1950 Series (4 mils wet, 1.6 mils dry per coat).
j. Flat Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-12600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-12600 Series (4 mils wet, 1.6 mils dry per coat).
k. Flat Scuff Resistant Waterbase Enamel.
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series (4 mils wet, 1.4 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
SECTION G - Page 18
APPENDIX
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4 mils wet, 1.7 mils dry per coat). b. Semi-Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
3. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5 mils wet, 2.0 mils dry per coat).
B. Concrete Ceilings: Poured Concrete, Precast Concrete, Cement Board, and Cast-In-Place including Plaster Ceilings.
1. Dryfall Waterborne Topcoats:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series. 2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series (5.8 mils wet, 2.3 mils dry per coat).
b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182
SECTION G - Page 19
APPENDIX
Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series (6 mils wet, 1.9 mils dry per coat).
c. Flat Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series (6 mils wet, 1.7 mils dry per coat).
C. Masonry CMU: Concrete, Split Face, Scored, Smooth, High Density, Low Density, and Fluted.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series (6.0 mils wet, 2.5 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series (4 mils wet, 1.5 mils dry per coat).
c. Semi-Gloss Finish: High Performance (HP) Upgrade.
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series (4 mils wet, 1.6 mils dry per coat).
d. Semi- Gloss Scuff Resistant Waterbase Enamel.
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series:
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series (4 mils wet, 1.2 mils dry per coat). e. Eg-Shel / Satin Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series (4 mils wet, 1.7 mils dry per coat).
f. Eg-Shel / Satin Finish: High Performance (HP) Upgrade. 1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series (4 mils wet, 1.7 mils dry per coat).
g. Eg-Shel/Satin Scuff Resistant Waterbase Enamel.
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series 3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgPage 409 of 517 SECTION G - Page 20
APPENDIX
Shel, S24-50 Series (4 mils wet, 1.2 mils dry per coat). h. Low Sheen Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Eg-Shel, B41- 2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Eg-Shel, B41- 2600 Series (4 mils wet, 1.6 mils dry per coat).
i. Low Sheen Finish: High Performance (HP) Upgrade
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Eg-Shel, B41-1950 Series.
3) 3rd Coat: S-W 200 HP Zero VOC Latex Low Gloss Eg-Shel, B41-1950 Series (4 mils wet, 1.6 mils dry per coat).
j. Flat Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-12600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-12600 Series (4 mils wet, 1.6 mils dry per coat).
k. Flat Scuff Resistant Waterbase Enamel.
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series (4 mils wet, 1.4 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). b. Semi-Gloss Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
3. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Block Surfacer, LX01W200 (50-100 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
SECTION G - Page 21
APPENDIX
1) 1st Coat: S-W Loxon Block Surfacer, LX01W200 (50-100 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Loxon Block Surfacer, LX01W200 (50-100 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4.0 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Loxon Block Surfacer, LX01W200 (50-100 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
D. Metal: Aluminum and Galvanized.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series (2.0-4.0 mils dry per coat).
b. Semi-Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series (2.0-
4.0 mils dry per coat).
c. Eg-Shel / Satin Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series (2.0-4.0 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
SECTION G - Page 22
APPENDIX
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
3. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
4. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Waterbased Acrolon 100, B65-720 series. 3) 3rd Coat: S-W Waterbased Acrolon 100, B65-720 series (4.0 mils wet,
2.0 mils dry per coat).
b. Gloss Finish Single Component:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane
SECTION G - Page 23
APPENDIX
Gloss, B65-120 Series (6.0-12.0 mils wet. 1.9-3.8 mils dry per coat).
E. Metal; Galvanized: Ceilings and Duct work.
1. Dryfall Waterborne Topcoats:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series. 2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series (5.8 mils wet, 2.3 mils dry per coat).
b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series (6.0 mils wet, 1.9 mils dry per coat).
c. Flat Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series (6.0 mils wet, 1.7 mils dry per coat).
F. Metal: Structural Steel Columns, Joists, Trusses, Beams, Miscellaneous and Ornamental Iron, Structural Iron, and Ferrous Metal.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series (2.0-4.0.0 mils dry per coat).
b. Semi-Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series (2.0-
4.0 mils dry per coat).
c. Eg-Shel / Satin Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series (2.0-4.0 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
SECTION G - Page 24
APPENDIX
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W -W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
3. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
4. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Waterbased Acrolon 100, B65-720 Series. 3) 3rd Coat: S-W Waterbased Acrolon 100, B65-720 Series (4.0 mils wet, 2 mils dry per coat).
b. Gloss Finish Single Component:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
SECTION G - Page 25
APPENDIX
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6.0-12.0 mils wet. 1.9-3.8 mils dry per coat).
5. Dryfall Waterborne Topcoat:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series.
3) 3rd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series (5.8 mils wet, 2.3 mils dry per coat).
b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series.
3) 3rd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series (6.0 mils wet, 1.9 mils dry per coat).
c. Flat Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series.
3) 3rd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series (6.0 mils wet, 1.7 mils dry per coat).
G. Wood: Walls, ceilings, doors, and trim.
1. Latex Systems:
a. Gloss Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W ProClassic Waterborne Acrylic Gloss, B21-51 Series. 3) 3rd Coat: S-W ProClassic Waterborne Acrylic Gloss, B21-51 Series (4 mils wet, 1.5 mils dry per coat).
b. Semi - Gloss Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W ProClassic Waterborne Acrylic Semi-Gloss, B31 Series. 3) 3rd Coat: S-W ProClassic Waterborne Acrylic Semi-Gloss, B31 Series (4 mils wet, 1.3 mils dry per coat).
c. Semi - Gloss Scuff Resistant Waterbase Enamel:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series:
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series (4 mils wet, 1.2 mils dry per coat). d. Eg-Shel / Satin Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
SECTION G - Page 26
APPENDIX
2) 2nd Coat: S-W ProClassic Waterborne Acrylic Satin, B20 Series. 3) 3rd Coat: S-W ProClassic Waterborne Acrylic Satin, B20 Series (4 mils wet, 1.2 mils dry per coat).
e. Eg-Shel / Satin Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111. (4 mils wet, 1.8 mils dry)
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series:
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series (4 mils wet, 1.2 mils dry per coat). f. Flat Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111. (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-2600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-2600 Series (4 mils wet, 1.6 mils dry per coat).
g. Flat Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111. (4 mils wet, 1.8 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series.
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series: 4 mils wet, 1.4 mils dry per coat.
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Premium Wood and Wall Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). b. Semi-Gloss Finish:
1) 1st Coat: S-W Premium Wood and Wall Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W Premium Wood and Wall Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
3. Stain and Varnish System:
a. Gloss Finish:
1) 1st Coat: SW Minwax Performance Series Tintable Wood Stain 250 VOC.
2) 2nd Coat: S-W Minwax Waterbased Oil-Modified Polyurethane. 3) 3rd Coat: S-W Minwax Waterbased Oil-Modified Polyurethane (4 mils
SECTION G - Page 27
APPENDIX
wet, 1.0 mil dry per coat).
b. Satin Finish:
1) 1st Coat: SW Minwax Performance Series Tintable Wood Stain 250 VOC.
2) 2nd Coat: S-W Minwax Waterbased Oil-Modified Polyurethane. 3) 3rd Coat: S-W Minwax Waterbased Oil-Modified Polyurethane (4 mils wet, 1.0 mil dry per coat).
H. Drywall: Walls, Ceilings, Gypsum Board and similar items.
1. Latex Systems:
a. Semi-Gloss Finish:
1) 1st Coat: S-W ProMar200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Semi-Gloss, B31-2600 Series (4 mils wet, 1.5 mils dry per coat).
b. Semi-Gloss Finish: High Performance (HP) Upgrade.
1) 1st Coat: S-W ProMar200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Semi-Gloss, B31-1950 Series (4 mils wet, 1.6 mils dry per coat).
c. Semi-Gloss Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: S-W ProMar200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series:
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series (4 mils wet, 1.2 mils dry per coat). d. Eg-Shel / Satin Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Eg-Shel, B20-2600 Series (4 mils wet, 1.7 mils dry per coat).
e. Eg-Shel / Satin Finish: High Performance (HP) Upgrade. 1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Eg-Shel, B20-1950 Series (4 mils wet, 1.7 mils dry per coat).
f. Eg-Shel Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: Sherwin-Williams ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry per coat).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series. 3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series (4 mils wet, 1.2 mils dry per coat).
SECTION G - Page 28
APPENDIX
g. Low Sheen Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Egshel, B41- 2600 Series.
3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Low Gloss Egshel, B41- 2600 Series (4 mils wet, 1.6 mils dry per coat).
h. Low Sheen Finish: High Performance (HP) Upgrade.
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Egshel, B41-1950 Series.
3) 3rd Coat: S-W ProMar 200 HP Zero VOC Latex Low Gloss Egshel, B41-1950 Series (4 mils wet, 1.6 mils dry per coat).
i. Flat Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-12600 Series. 3) 3rd Coat: S-W ProMar 200 Zero VOC Latex Flat, B30-12600 Series (4 mils wet, 1.6 mils dry per coat).
j. Flat Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: Sherwin-Williams ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry per coat).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series (4 mils wet, 1.4 mils dry per coat).
2. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600
SECTION G - Page 29
APPENDIX
(4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
I. Concrete: Floors, non-vehicular.
1. Latex Systems:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Tread-Plex Acrylic Floor Coating, B90 Series. 2) 2nd Coat: S-W Tread-Plex Acrylic Floor Coating, B90 Series. (3.5 mils wet, 1.5 mils dry, per coat).
b. Satin Finish:
1) 1st Coat: S-W Porch and Floor Enamel, A32-200 Series. 2) 2nd Coat: S-W Porch and Floor Enamel, A32-200 Series (4 mils wet,
1.5 mils dry per coat).
3.6 INTERIOR PAINT AND COATING HEALTHCARE SYSTEMS
A. Concrete: Walls and Ceilings, Poured Concrete, Precast Concrete, Unglazed Brick, Cement Board, Tilt-Up, Cast-In-Place including Plaster Walls and Ceilings.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series (6.0 mils wet, 2.5 mils dry per coat).
b. Semi-Gloss Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Series Semi-Gloss, A88 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Series Semi-Gloss, A88 Series (4 mils wet, 1.7 mils dry per coat). c. Semi-Gloss Finish Scuff Resistant Waterbase Enamel.
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series:
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series: 4 mils wet, 1.2 mils dry per coat. d. Eg-Shel / Satin Finish: Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Series Satin, A87 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Series Satin, A87 Series (4 mils wet, 1.6 mils dry per coat). e. Eg-Shel/ Satin Finish Scuff Resistant Waterbase Enamel. 1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50
SECTION G - Page 30
APPENDIX
(8 mils wet, 3.2 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series 3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series (4 mils wet, 1.2 mils dry per coat). f. Flat Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Series Flat, A86 Series.
3) 3rd Coat: S-W Superpaint Air Purifying Technology Interior Acrylic Series Flat, A86 Series (4 mils wet, 1.8 mils dry per coat). g. Flat Finish Scuff Resistant Waterbase Enamel.
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series (4 mils wet, 1.4 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W ProIndustrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4 mils wet, 1.7 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
3. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46-
SECTION G - Page 31
APPENDIX
Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5 mils wet, 2.0 mils dry per coat).
B. Concrete: Ceilings, Poured Concrete, Precast Concrete, Cement Board, Cast-In-Place including Plaster Ceilings.
1. Dryfall Waterborne Topcoats:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series. 2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series (5.8 mils wet, 2.3 mils dry per coat).
b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series (6 mils wet, 1.9 mils dry per coat).
c. Flat Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series (6 mils wet, 1.7 mils dry per coat).
C. Masonry CMU: Concrete, Split Face, Scored, Smooth, High Density, Low Density, and Fluted.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Gloss Acrylic Coating, B66-600 Series (6.0 mils wet, 2.5 mils dry per coat).
b. Semi-Gloss Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Semi-Gloss, A88 Series.
3) 3rd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Semi-Gloss, A88 Series: (4 mils wet, 1.7 mils dry per coat.) c. Semi-Gloss Finish Scuff Resistant Waterbase Enamel.
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiPage 421 of 517 SECTION G - Page 32
APPENDIX
Gloss, S26-50 Series:
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series (4 mils wet, 1.2 mils dry per coat). d. Eg-Shel / Satin Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Satin, A87 Series:.
3) 3rd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Satin, A87 Series: (4 mils wet, 1.6 mils dry per coat). e. Eg-Shel/ Satin Finish Scuff Resistant Waterbase Enamel. 1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series 3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series (4 mils wet, 1.2 mils dry per coat). f. Flat Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Flat, A86 Series.
3) 3rd Coat: S-W SuperPaint Air Purifying Technology, Flat, A86 Series (4 mils wet, 1.8 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Flat Finish Scuff Resistant Waterbase Enamel.
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series (4 mils wet, 1.4 mils dry per coat).
b. Gloss Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Semi-Gloss Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). d. Low Sheen Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
3. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Block Surfacer, LX01W200 (50-100 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
SECTION G - Page 33
APPENDIX
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Loxon Block Surfacer, LX01W200 (50-100 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Loxon Block Surfacer, LX01W200 (50-100 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4.0 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Loxon Block Surfacer, LX01W200 (50-100 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
D. Metal: Aluminum, Galvanized.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series (2.0-4.0 mils dry per coat).
b. Semi-Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series (2.0-
4.0 mils dry per coat).
c. Eg-Shel / Satin Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series (2.0-4.0 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310
SECTION G - Page 34
APPENDIX
Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
3. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
4. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Waterbased Acrolon 100, B65-720 series. 3) 3rd Coat: S-W Waterbased Acrolon 100, B65-720 series (4.0 mils wet,
2.0 mils dry per coat).
b. Gloss Finish Single Component:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
SECTION G - Page 35
APPENDIX
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6.0-12.0 mils wet. 1.9-3.8 mils dry per coat).
E. Metal: Galvanized; Ceilings, Duct work.
1. Dryfall Waterborne Topcoats:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series. 2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series (5.8 mils wet, 2.3 mils dry per coat).
b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series (6.0 mils wet, 1.9 mils dry per coat).
c. Flat Finish:
1) 1st Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series.
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series (6.0 mils wet, 1.7 mils dry per coat).
F. Metal: Structural Steel Columns, Joists, Trusses, Beams, Miscellaneous and Ornamental Iron, Structural Iron, and Ferrous Metal.
1. Latex Systems:
a. Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series (2.0-4.0.0 mils dry per coat).
b. Semi-Gloss Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series (2.0-
4.0 mils dry per coat).
c. Eg-Shel / Satin Finish High Performance:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series (2.0-4.0 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
SECTION G - Page 36
APPENDIX
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W -W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
3. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
4. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Waterbased Acrolon 100, B65-720 Series. 3) 3rd Coat: S-W Waterbased Acrolon 100, B65-720 Series (4.0 mils wet, 2 mils dry per coat).
SECTION G - Page 37
APPENDIX
b. Gloss Finish Single Component:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6.0-12.0 mils wet. 1.9-3.8 mils dry per coat).
5. Dryfall Waterborne Topcoat:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series.
3) 3rd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-83 Series (5.8 mils wet, 2.3 mils dry per coat).
b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series.
3) 3rd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-182 Series (6.0 mils wet, 1.9 mils dry per coat).
c. Flat Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series.
3) 3rd Coat: S-W Pro Industrial Waterborne Acrylic Dryfall, B42-181 Series (6.0 mils wet, 1.7 mils dry per coat).
G. Wood: Walls, Ceilings, Doors, and Trim.
1. Latex Systems:
a. Gloss Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W ProClassic Waterborne Acrylic Gloss, B21-51 Series. 3) 3rd Coat: S-W ProClassic Waterborne Acrylic Gloss, B21-51 Series (4 mils wet, 1.5 mils dry per coat).
b. Semi-Gloss Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series:
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series (4 mils wet, 1.2 mils dry per coat). c. Semi - Gloss Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W ProClassic Waterborne Acrylic Semi-Gloss, B31 Series. 3) 3rd Coat: S-W ProClassic Waterborne Acrylic Semi-Gloss, B31 Series (4 mils wet, 1.3 mils dry per coat).
SECTION G - Page 38
APPENDIX
d. Semi-Gloss Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Semi-Gloss, A88 Series.
3) 3rd Coat: S-W SuperPaint Air Purifying Technology, Semi-Gloss, A88 Series (4 mils wet, 1.8 mils dry per coat).
e. Eg-Shel / Satin Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W ProClassic Waterborne Acrylic Satin, B20 Series. 3) 3rd Coat: S-W ProClassic Waterborne Acrylic Satin, B20 Series (4 mils wet, 1.2 mils dry per coat).
f. Eg-Shel / Satin Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series 3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series (4 mils wet, 1.2 mils dry per coat). g. Eg-Shel/ Satin Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Satin, A87 Series.
3) 3rd Coat: S-W SuperPaint Air Purifying Technology, Satin, A87 Series (4 mils wet, 1.8 mils dry per coat).
h. Flat Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Flat, A86 Series.
3) 3rd Coat: S-W SuperPaint Air Purifying Technology, Flat, A86 Series (4 mils wet, 1.8 mils dry per coat).
i. Flat Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series (4 mils wet, 1.4 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Premium Wood and Wall Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). b. Semi-Gloss Finish:
1) 1st Coat: S-W Premium Wood and Wall Primer, B28W8111 (4 mils
SECTION G - Page 39
APPENDIX
wet, 1.8 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W Premium Wood and Wall Primer, B28W8111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
3. Stain and Varnish System:
a. Gloss Finish:
1) 1st Coat: SW Minwax Performance Series Tintable Wood Stain 250 VOC.
2) 2nd Coat: S-W Minwax Waterbased Oil-Modified Polyurethane. 3) 3rd Coat: S-W Minwax Waterbased Oil-Modified Polyurethane (4 mils wet, 1.0 mil dry per coat).
b. Satin Finish:
1) 1st Coat: SW Minwax Performance Series Tintable Wood Stain 250 VOC.
2) 2nd Coat: S-W Minwax Waterbased Oil-Modified Polyurethane. 3) 3rd Coat: S-W Minwax Waterbased Oil-Modified Polyurethane (4 mils wet, 1.0 mil dry per coat).
H. Drywall: Walls, Ceilings, Gypsum Board and similar items.
1. Latex Systems:
a. Semi-Gloss Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Semi-Gloss, A88 Series.
3) 3rd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Semi-Gloss, A88 Series: (4 mils wet, 1.7 mils dry per coat.) b. Semi-Gloss Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: Sherwin-Williams ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry per coat).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series:
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, SemiGloss, S26-50 Series: (4 mils wet, 1.2 mils dry per coat). c. Eg-Shel / Satin Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Satin, A87 Series:.
3) 3rd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Satin, A87 Series: (4 mils wet, 1.6 mils dry per coat). d. Eg-Shel / Satin Finish Microbicidal Latex Finish System: With topcoat EPA registered No. 64695-1:
SECTION G - Page 40
APPENDIX
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W SuperPaint Interior Latex Satin with Sanitizing Technology, A87W00001.
3) 3rd Coat: S-W SuperPaint Interior Latex Satin with Sanitizing Technology, A87W00001 (4 mils wet, 1.7 mils dry per coat). e. Eg-Shel Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: Sherwin-Williams ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry per coat).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series 3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, EgShel, S24-50 Series (4 mils wet, 1.2 mils dry per coat). f. Flat Finish Formaldehyde and Odor Reducing:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: Sherwin-Williams SuperPaint Air Purifying Technology, Flat, A86 Series.
3) 3rd Coat: S-W SuperPaint Air Purifying Technology, Flat, A86 Series (4 mils wet, 1.8 mils dry per coat).
g. Flat Finish Scuff Resistant Waterbase Enamel:
1) 1st Coat: Sherwin-Williams ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry per coat).
2) 2nd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series
3) 3rd Coat: Sherwin-Williams Scuff Tuff Int. Waterbased Enamel, Matte, S23-50 Series (4 mils wet, 1.4 mils dry per coat).
2. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-300 Series (5.0 mils wet, 2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K46- Series (4 mils wet, 1.5 mils dry per coat).
c. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600 (4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Epoxy, K45- Series (4 mils wet, 1.5 mils dry per coat).
d. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Interior Latex Primer, B28W2600
SECTION G - Page 41
APPENDIX
(4 mils wet, 1.5 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy, B73-360 Series (5.0 mils wet, 2.0 mils dry per coat).
I. Concrete: Floors, non-vehicular:
1. Latex Systems:
a. Semi-Gloss Finish:
1) 1st Coat: S-W Tread-Plex Acrylic Floor Coating, B90 Series. 2) 2nd Coat: S-W Tread-Plex Acrylic Floor Coating, B90 Series. (3.5 mils wet, 1.5 mils dry, per coat).
b. Satin Finish:
1) 1st Coat: S-W Porch and Floor Enamel, A32-200 Series. 2) 2nd Coat: S-W Porch and Floor Enamel, A32-200 Series (4 mils wet,
1.5 mils dry per coat).
3.7 HIGH PERFORMANCE INTERIOR PAINT AND COATING SYSTEMS A. Concrete; Smooth: Walls and Ceilings, Poured Concrete, Precast Concrete, Unglazed Brick, Cement Board, Tilt-Up, and Cast-In-Place.
1. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series.
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat). b. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series.
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat).
2. Epoxy Systems; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Tile-Clad HS Epoxy Gloss, B62Z/B60VZ70 Series. 2) 2nd Coat: S-W Tile-Clad HS Epoxy Gloss, B62Z/B60VZ70 Series (4.0-
7.0 mils wet, 2.5-4.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series. 2) 2nd Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
3. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer/Sealer, LX02W50 Series (5.3-8.0 mils wet. 2.1-3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series (4.0-8.0 mils wet, 1.8-3.6 mils dry per coat).
b. Gloss Finish Single Component:
1) 1st Coat: S-W Loxon Concrete & Masonry Primer/Sealer, LX02W50
SECTION G - Page 42
APPENDIX
Series (5.3-8.0 mils wet. 2.1-3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6.0-12.0 mils wet,1.9-3.8 mils dry per coat).
4. Urethane Systems: Solvent Base Finish.
a. Gloss Finish:
1) 1st Coat: S-W Kem Cati-Coat HS Epoxy Filler/Sealer, B42-400 Series (14.0-28.0 mils wet, 10.0-20.0 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series. 3) 3rd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series (4.5-
8.0 mils wet, 3.0-5.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Kem Cati-Coat HS Epoxy Filler/Sealer, B42-400 Series (14.0-28.0 mils wet, 10.0-20.0 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series.
3) 3rd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
5. Polysiloxane System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Concrete & Masonry Primer/Sealer, LX02W50 Series (5.3-8.0 mils wet. 2.1-3.2 mils dry).
2) 2nd Coat: S-W Sher-loxane 800, (5.0-7.0 mils wet, 4.0-6.0 mils dry per coat).
B. Concrete: Exposed Ceilings.
1. MultiSurface Acrylic Coating:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Gloss, B66-1500 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Gloss, B66-1500 Series (3.7-5.0 mils wet, 1.5-2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Semi-Gloss, B66- 1550 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Semi-Gloss, B66- 1550 Series (3.75-5.0 mils wet, 1.5-2.0 mils dry per coat). c. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Eg-Shel, B66-1560 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Eg-Shel, B66-1560 Series (3.75-5.0 mils wet, 1.5-2.0 mils dry per coat).
d. Matte Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Matte, B66-1570 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Matte, B66-1570 Series (3.75-5.0 mils wet, 1.5-2.4 mils dry per coat).
C. Masonry CMU: Concrete, Split Face, Scored, Smooth, High Density, Low Density, Fluted, and Stucco.
SECTION G - Page 43
APPENDIX
1. Epoxy System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Heavy Duty Block Filler, B42W46 (18.0-34.0 mils wet,
10.0-18.0 mils wet).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat). b. Eg-Shel/Low Luster Finish:
1) 1st Coat: S-W Heavy Duty Block Filler, B42W46 (18.0-13.0 mils wet,
10.0-18.0 mils wet).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat).
2. Epoxy Systems; Solvent Base Finish:
a. Gloss Finish:
1) 1st Coat: S-W Kem Cati-Coat HS Epoxy Filler/Sealer, B42-400 Series (14.0-28.0 mils wet, 10.0-20.0 mils dry).
2) 2nd Coat: S-W Tile-Clad HS Epoxy Gloss, B62Z/B60VZ Series. 3) 3rd Coat: S-W Tile-Clad HS Epoxy Gloss, B62Z/B60VZ Series (4.0-7.0 mils wet, 2.5-4.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Kem Cati-Coat HS Epoxy Filler/Sealer, B42-400 Series (14.0-28.0 mils wet, 10.0-20.0 mils dry).
2) 2nd Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series. 3) 3rd Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
3. Urethane Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Heavy Duty Block Filler, B42W46 (18.0-34.0 mils wet.
10.0-18.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series (4.0-8.0 mils wet, 1.8-3.6 mils dry per coat).
b. Gloss Finish Single Component:
1) 1st Coat: S-W Heavy Duty Block Filler, B42W46 (18.0-34.0 mils wet.
10.0-18.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6.0-12.0 mils wet. 1.9-3.8 mils dry per coat).
4. Urethane Systems; Solvent Base Finish:
a. Gloss Finish:
1) 1st Coat: S-W Kem Cati-Coat HS Epoxy Filler/Sealer, B42-400 Series (14.0-28.0 mils wet, 10.0-20.0 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series. 3) 3rd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series (4.5-
8.0 mils wet, 3.0-5.0 mils dry per coat).
b. Semi-Gloss Finish:
SECTION G - Page 44
APPENDIX
1) 1st Coat: S-W Kem Cati-Coat HS Epoxy Filler/Sealer, B42-400 Series (14.0-28.0 mils wet, 10.0-20.0 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series.
3) 3rd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
5. Polysiloxane System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Kem Cati-Coat HS Epoxy Filler/Sealer, B42-400 Series (14.0-28.0 mils wet, 10.0-20.0 mils dry).
2) 2nd Coat: : S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-13.5 mils wet, 5.0-10.0 mils dry per coat).
3) 3rd Coat: S-W Sher-loxane 800, (5.0-7.0 mils wet, 4.0-6.0 mils dry per coat).
D. Non-Ferrous: Galvanized and Aluminum.
1. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0-10.0 mils wet, 1.8-3.6 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat). b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series (5.0-10 mils wet, 2.0-4.0 mils dry per coat).
2. Epoxy Systems; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Tile-Clad HS Epoxy, B62Z/B60VZ Series. 2) 2nd Coat: S-W Tile-Clad HS Epoxy, B62Z/B60VZ Series (4.0-7.0 mils wet, 2.5-4.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series. 2) 2nd Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
3. Urethane Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W DTM Wash Primer, B71Y1 (3.4-6.4 mils wet, 0.7-1.3 mils dry).
2) 2nd Coat: S-W Pro-Industrial Waterbased Acrolon 100 Gloss, B65-720 Series.
3) 3rd Coat: S-W Pro-Industrial Waterbased Acrolon 100 Gloss, B65-720 Series (4.0-8.0 mils wet, 1.8-3.6 mils dry per coat).
b. Gloss Finish Single Component:
1) 1st Coat: S-W DTM Wash Primer, B71Y1 (3.4-6.4 mils wet, 0.7-1.3 mils dry).
SECTION G - Page 45
APPENDIX
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6.0-12.0 mils wet, 1.9-3.8 mils dry per coat).
4. Urethane Systems; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W DTM Wash Primer, B71Y1 (3.4-6.4 mils wet, 0.7-1.3 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series. 3) 3rd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series (4.5-
8.0 mils wet, 3.0-5.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W DTM Wash Primer, B71Y1 (3.4-6.4 mils wet, 0.7-1.3 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series.
3) 3rd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
5. Polysiloxane System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Sher-loxane 800, (5.0-7.0 mils wet, 4.0-6.0 mils dry per coat).
6. Fluoropolymer System: Pigmented Fluoropolymer over Epoxy Intermediate and Epoxy Zinc-Rich Primer system.
a. Gloss Finish:
1) 1st Coat: S-W Zinc Clad 4100 Organic Zin-Rich Epoxy Primer (3.0-5.0 mils dry).
2) 2nd Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
3) 3rd Coat: S-W Fluorokem HS 100, B65 Series, (5.0-7.0 mils wet, 4.0-
6.0 mils dry per coat).
7. Multi-Surface Acrylic Coating: Exposed Ceilings.
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Gloss, B66-1500 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Gloss, B66-1500 Series (3.7-5.0 mils wet, 1.5-2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Semi-Gloss, B66- 1550 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Semi-Gloss, B66- 1550 Series (3.75-5.0 mils wet, 1.5-2.0 mils dry per coat). c. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Eg-Shel, B66-1560 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Eg-Shel, B66-1560 Series (3.75-5.0 mils wet, 1.5-2.0 mils dry per coat).
d. Matte Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Matte, B66-1570
SECTION G - Page 46
APPENDIX
Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Matte, B66-1570 Series (3.75-5.0 mils wet, 1.5-2.4 mils dry per coat).
E. Metal: Structural Steel Columns, Joists, Trusses, Beams, Miscellaneous and Ornamental Iron, Structural Iron, and Ferrous Metal.
1. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0-10.0 mils wet, 1.8-3.6 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat). b. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0-10.0 mils wet, 1.8-3.6 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat).
2. Epoxy System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Macropoxy 646 Fast Cure Epoxy, B58-600 Series. (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Tile-Clad HS Epoxy, B62Z/B60VZ Series. 3) 3rd Coat: S-W Tile-Clad HS Epoxy, B62Z/B60VZ Series (4.0-7.0 mils wet, 2.5-4.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Macropoxy 646 Fast Cure Epoxy, B58-600 Series. 2) 2nd Coat: S-W Macropoxy 646 Fast Cure Epoxy, B58-600 Series. (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
3. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series. (5.0-10.0 mils wet, 1.8-3.6 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series. (4.0-8.0 mils wet, 1.8-3.6 mils dry per coat).
b. Gloss Finish Single Component:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series. (5.0-10.0 mils wet, 1.8-3.6 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series. (6.0-12.0 mils wet, 1.9-3.8 mils dry per coat).
4. Urethane System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-13.5 mils wet, 5.0-10.0 mils dry per coat).
SECTION G - Page 47
APPENDIX
2) 2nd Coat: S-W Hi-Solids Polyurethane Gloss, B65-300 Series. 3) 3rd Coat: S-W Hi-Solids Polyurethane Gloss, B65-300 Series. (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350 Series. 3) 3rd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350 Series. (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
5. Polysiloxane System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Sher-loxane 800, (5.0-7.0 mils wet, 4.0-6.0 mils dry per coat).
6. Fluoropolymer System: Pigmented Fluoropolymer over Epoxy Intermediate and Epoxy Zinc-Rich Primer system.
a. Gloss Finish:
1) 1st Coat: S-W Zinc Clad 4100 Organic Zin-Rich Epoxy Primer (3.0-5.0 mils dry).
2) 2nd Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
3) 3rd Coat: S-W Fluorokem HS 100, B65 Series, (5.0-7.0 mils wet, 4.0-
6.0 mils dry per coat).
F. Metal Exposed Ceilings: Structural Steel, Joists, Trusses, and Beams.
1. MultiSurface Acrylic Coating:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Gloss, B66-1500 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Gloss, B66-1500 Series (3.75-5.0 mils wet, 1.5-2.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Semi-Gloss, B66- 1550 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Semi-Gloss, B66- 1550 Series (3.75-5.0 mils wet, 1.5-2.0 mils dry per coat). c. Eg-Shel Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Eg-Shel, B66-1560 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Eg-Shel, B66-1560 Series (3.75-5.0 mils wet, 1.5-2.0 mils dry per coat).
d. Matte Finish:
1) 1st Coat: S-W Pro Industrial Multi-Surface Acrylic Matte, B66-1570 Series.
2) 2nd Coat: S-W Pro Industrial Multi-Surface Acrylic Matte, B66-1570 Series (3.75-5.0 mils wet, 1.5-2.4 mils dry per coat).
G. Wood: Doors, Trim, Partitions, and Frames.
1. Epoxy System; Waterbased:
a. Gloss Finish:
SECTION G - Page 48
APPENDIX
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W08111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series. (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat). b. Eg-Shel Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W08111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series. (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat).
2. Epoxy System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W08111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W Tile-Clad HS Epoxy, B62Z/B60VZ70 Series. 3) 3rd Coat: S-W Tile-Clad HS Epoxy, B62Z/B60VZ70 Series (4.0-7.0 mils wet, 2.5-4.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W08111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W Macropoxy 646 Fast Cure Epoxy, B58-600 Series. 3) 3rd Coat: S-W Macropoxy 646 Fast Cure Epoxy, B58-600 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
H. Drywall: Walls, Ceilings, and Gypsum Board.
1. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Latex Primer, B28W02600 (4.0 mils wet, 1.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series. (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat). b. Eg-Shel Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Latex Primer, B28W02600 (4.0 mils wet, 1.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series. (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat).
2. Epoxy System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Latex Primer, B28W02600 (4.0 mils wet, 1.0 mils dry).
2) 2nd Coat: S-W Tile-Clad HS Epoxy, B62Z/B60VZ70 Series. 3) 3rd Coat: S-W Tile-Clad HS Epoxy, B62Z/B60VZ70 Series (4.0-7.0 mils wet, 2.5-4.0 mils dry per coat).
b. Semi-Gloss Finish:
SECTION G - Page 49
APPENDIX
1) 1st Coat: S-W ProMar 200 Zero VOC Latex Primer, B28W02600 (4.0 mils wet, 1.0 mils dry).
2) 2nd Coat: S-W Macropoxy 646 Fast Cure Epoxy, B58-600 Series 3) 3rd Coat: S-W Macropoxy 646 Fast Cure Epoxy, B58-600 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
3. Urethane Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Latex Primer, B28W02600 (4.0 mils wet, 1.0 mils dry).
2) 2nd Coat: S-W Pro-Industrial Waterbased Acrolon 100 Gloss, B65-720 Series.
3) 3rd Coat: S-W Pro-Industrial Waterbased Acrolon 100 Gloss, B65-720 Series (4.0-8.0 mils wet, 1.8-3.6 mils dry per coat).
b. Gloss Finish Single Component:
1) 1st Coat: S-W ProMar 200 Zero VOC Latex Primer, B28W02600 (4.0 mils wet, 1.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6.0-12.0 mils wet, 1.9-3.8 mils dry per coat).
4. Urethane Systems; Solvent Base:
a. Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Latex Primer, B28W02600 (4.0 mils wet, 1.0 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series. 3) 3rd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series (4.5-
8.0 mils wet, 3.0-5.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W ProMar 200 Zero VOC Latex Primer, B28W02600 (4.0 mils wet, 1.0 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series.
3) 3rd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
I. Plaster; Walls, Ceilings:
1. Epoxy Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (5.3-8.0 mils wet, 2.1-3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Gloss, B73- 300 Series. (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat). b. Eg-Shel Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (5.3-8.0 mils wet, 2.1-3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Catalyzed Epoxy Eg-Shel, B73-360 Series. (5.0-10.0 mils wet, 2.0-4.0 mils dry per coat).
SECTION G - Page 50
APPENDIX
3.8 HIGH PERFORMANCE EXTERIOR PAINT AND COATING SYSTEMS A. Concrete; Smooth: Walls and Ceilings, Poured Concrete, Precast Concrete, Unglazed Brick, Cement Board, Tilt-Up, and Cast-In-Place.
1. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series (4.0-8.0 mils wet, 1.8-3.6 mils dry per coat).
b. Gloss Finish Single Component:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (8 mils wet, 3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6.0-12.0 mils wet, 1.9-3.8 mils dry per coat).
2. Urethane System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer/Sealer, LX02W50 Series (5.3-8.0 mils wet. 2.1-3.2 mils dry.)
2) 2nd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series. 3) 3rd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series (4.5-
8.0 mils wet, 3.0-5.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Loxon Concrete & Masonry Primer/Sealer, LX02W50 Series (5.3-8.0 mils wet, 2.1-3.2 mils dry.
2) 2nd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series.
3) 3rd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
3. Polysiloxane System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Concrete & Masonry Primer/Sealer, LX02W50 Series (5.3-8.0 mils wet. 2.1-3.2 mils dry).
2) 2nd Coat: S-W Sher-loxane 800, (5.0-7.0 mils wet, 4.0-6.0 mils dry per coat).
B. Masonry; CMU: Concrete, Split Face, Scored, Smooth, High Density, Low Density, Fluted, and Stucco.
1. Urethane Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Heavy Duty Block Filler, B42W46 (18.0-34.0 mils wet,
10.0-18.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series (4.0-8.0 mils wet, 1.8-3.6 mils dry per coat).
SECTION G - Page 51
APPENDIX
b. Gloss Finish Single Component:
1) 1st Coat: S-W Heavy Duty Block Filler, B42W46 (18.0-34.0 mils wet,
10.0-18.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6.0-12.0 mils wet. 1.9-3.8 mils dry per coat).
2. Urethane Systems; Solvent Base Finish.
a. Gloss Finish:
1) 1st Coat: S-W Kem Cati-Coat HS Epoxy Filler/Sealer, B42-400 Series (14.0-28.0 mils wet, 10.0-20.0 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series. 3) 3rd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series (4.5-
8.0 mils wet, 3.0-5.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Kem Cati-Coat HS Epoxy Filler/Sealer, B42-400 Series (14.0-28.0 mils wet, 10.0-20.0 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series.
3) 3rd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
3. Polysiloxane System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Kem Cati-Coat HS Epoxy Filler/Sealer, B42-400 Series (14.0-28.0 mils wet, 10.0-20.0 mils dry).
2) 2nd Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
3) 3rd Coat: S-W Sher-loxane 800, (5.0-7.0 mils wet, 4.0-6.0 mils dry per coat).
C. Non-Ferrous Metal: Galvanized and Aluminum.
1. Urethane Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W DTM Wash Primer, B71Y1 (3.4-6.4 mils wet, 0.7-1.3 mils dry).
2) 2nd Coat: S-W Pro-Industrial Waterbased Acrolon 100 Gloss, B65-720 Series.
3) 3rd Coat: S-W Pro-Industrial Waterbased Acrolon 100 Gloss, B65-720 Series (4.0-8.0 mils wet, 1.8-3.6 mils dry per coat).
b. Gloss Finish; Single Component:
1) 1st Coat: S-W DTM Wash Primer, B71Y1 (3.4-6.4 mils wet, 0.7-1.3 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series (6.0-12.0 mils wet, 1.9-3.8 mils dry per coat).
2. Urethane Systems; Solvent Base:
a. Gloss Finish:
1) 1st Coat: S-W DTM Wash Primer, B71Y1 (3.4-6.4 mils wet, 0.7-1.3 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series.
SECTION G - Page 52
APPENDIX
3) 3rd Coat: S-W Hi-Solids Polyurethane Gloss, B65/B60-30 Series (4.5-
8.0 mils wet, 3.0-5.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W DTM Wash Primer, B71Y1 (3.4-6.4 mils wet, 0.7-1.3 mils dry).
2) 2nd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series.
3) 3rd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350/B60V30 Series (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
3. Polysiloxane System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Sher-loxane 800, (5.0-7.0 mils wet, 4.0-6.0 mils dry per coat).
4. Fluoropolymer System (Pigmented Fluoropolymer over Epoxy Intermediate and Epoxy Zinc-Rich Primer system):
a. Gloss Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Fluorokem HS 100, B65 Series, (5.0-7.0 mils wet, 4.0-
6.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Fluorokem HS 100, B65 Series, (5.0-7.0 mils wet, 4.0-
6.0 mils dry per coat).
c. Satin Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Fluorokem HS 100, B65 Series, (5.0-7.0 mils wet, 4.0-
6.0 mils dry per coat).
D. Metal - (Structural Steel Columns, Joists, Trusses, Beams, Miscellaneous and Ornamental Iron, Structural Iron, Ferrous Metal).
1. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series. (5.0-10.0 mils wet, 1.8-3.6 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Acrolon 100 Gloss, B65-720 Series. (4.0-8.0 mils wet, 1.8-3.6 mils dry per coat).
b. Gloss Finish Single Component:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series. (5.0-10.0 mils wet, 1.8-3.6 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyed Waterbased Urethane Gloss, B65-120 Series. (6.0-12.0 mils wet, 1.9-3.8mils dry per coat).
2. Urethane System; Solvent Base:
SECTION G - Page 53
APPENDIX
a. Gloss Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Hi-Solids Polyurethane Gloss, B65-300 Series. 3) 3rd Coat: S-W Hi-Solids Polyurethane Gloss, B65-300 Series. (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350 Series. 3) 3rd Coat: S-W Hi-Solids Polyurethane Semi-Gloss, B65-350 Series. (4.5-8.0 mils wet, 3.0-5.0 mils dry per coat).
3. Polysiloxane System; Solvent Based:
a. Gloss Finish:
1) 1st Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet, 5.0-10.0 mils dry per coat).
2) 2nd Coat: S-W Sher-loxane 800, (5.0-7.0 mils wet, 4.0-6.0 mils dry per coat).
4. Fluoropolymer System: Pigmented Fluoropolymer over Epoxy Intermediate and Epoxy Zinc-Rich Primer system.
a. Gloss Finish:
1) 1st Coat: S-W Zinc Clad 4100 Organic Zin-Rich Epoxy Primer (3.0-5.0 mils dry).
2) 2nd Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet. 5.0-10.0 mils dry per coat).
3) 3rd Coat: S-W Fluorokem HS 100, B65 Series (5.0-7.0 mils wet. 4.0-6.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Zinc Clad 4100 Organic Zin-Rich Epoxy Primer (3.0-5.0 mils dry).
2) 2nd Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet. 5.0-10.0 mils dry per coat).
3) 3rd Coat: S-W Fluorokem HS 100, B65 Series (5.0-7.0 mils wet. 4.0-6.0 mils dry per coat).
c. Satin Finish:
1) 1st Coat: S-W Zinc Clad 4100 Organic Zin-Rich Epoxy Primer (3.0-5.0 mils dry).
2) 2nd Coat: S-W Macropoxy 646-100 Fast Cure Epoxy, B58 Series (7.0-
13.5 mils wet. 5.0-10.0 mils dry per coat).
3) 3rd Coat: S-W Fluorokem HS 100, B65 Series (5.0-7.0 mils wet. 4.0-6.0 mils dry per coat).
E. Wood: Doors, Trim, Partitions, and Frames.
1. Urethane System; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Premium Wall and Wood Primer, B28W08111 (4 mils wet, 1.8 mils dry).
2) 2nd Coat: S-W Pro Industrial Pre-Catalyzed Waterbased Urethane Gloss, B65-120 Series.
3) 3rd Coat: S-W Pro Industrial Pre-Catalyed Waterbased Urethane Gloss, B65-120 Series. (6.0-12.0 mils wet, 1.9-3.8 mils dry per coat).
SECTION G - Page 54
APPENDIX
3.9 EXTERIOR PAINT AND COATING SYSTEMS
A. Concrete: Cementitious Siding, Flexboard, Transite Board, Non-Roof Shingles, Common Brick, Stucco, Tilt-up, Precast, and Poured-in-place Cement.
1. Latex Systems:
a. Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (5.3-8.0 mils wet, 2.1-3.2 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Gloss, A8 Series. 3) 3rd Coat: S-W A-100 Exterior Latex Gloss, A8 Series (4.0 mils wet, 1.3 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (5.3-8.0 mils wet, 2.1-3.2 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. (6.0-
12.0 mils wet, 2.0-4.0 mils dry per coat).
c. Satin Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (5.3-8.0 mils wet, 2.1-3.2 dry).
2) 2nd Coat: S-W A-100 Exterior Latex Satin, A82 Series. 3) 3rd Coat: S-W A-100 Exterior Latex Satin, A82 Series (4.0 mils wet, 1.5 mils dry per coat).
d. Satin Finish Self Cleaning Upgrade:
1) 1st Coat: S-W Loxon Self Cleaning Acrylic Coating-Satin, LX14-50 Series.
2) 2nd Coat: S-W Loxon Self Cleaning Acrylic Coating-Satin, LX14-50 Series (5.0-7.0 mils wet, 2.0-2.8 dry per coat).
e. Flat Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (5.3-8.0 mils wet, 2.1-3.2 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Flat, A6 Series.
3) 3rd Coat: S-W A-100 Exterior Latex Flat, A6 Series (4.0 mils wet, 1.2 mils dry per coat).
f. Flat Finish Self Cleaning Upgrade:
1) 1st Coat: S-W Loxon Self Cleaning Acrylic Coating-Flat, LX13-50 Series.
2) 2nd Coat: S-W Loxon Self Cleaning Acrylic Coating-Flat, LX13-50 Series (5.0-7.0 mils wet, 2.0-2.8 dry per coat).
2. Elastomeric System: Not including cementitious siding, Flexboard, Transite board or shingles (non-roof).
a. Flat Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (5.3-8.0 mils wet, 2.1-3.2 mils dry).
2) 2nd Coat: S-W ConFlex XL Elastomeric High Build Coating, CF11W50 Series.
3) 3rd Coat: S-W ConFlex XL Elastomeric High Build Coating, CF11W50 Series (13.0-16.0 mils wet, 6.0-7.5 mils dry per coat). b. Flat Finish:
1) 1st Coat: S-W Loxon BlockSurfacer, A24W00200 (16.0 mils wet, 8.8
SECTION G - Page 55
APPENDIX
mils dry).
2) 2nd Coat: S-W Conflex SherLastic Elastomeric Masonry Coating, CF16W50 Series.
3) 3rd Coat: S-W Conflex SherLastic Elastomeric Masonry Coating, CF16W50 Series (10.0-14.0 mils wet, 4.0-6.0 mils dry per coat).
3. Textured Elastomeric System:
a. Textured Finish:
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (5.3-8.0 mils wet, 2.1-3.2 mils dry).
2) 2nd Coat: S-W ConFlex XL Elastomeric High Build Coating, CF11W50 Series (13.0-16.0 mils wet, 6.0-7.5 mils dry per coat). 3) 3rd Coat: S-W ConFlex XL Textured Elastomeric High Build Coating, CF15W50 Series (20.0-23.0 mils wet, 9.4-11.0 mils dry per coat). a) Finish Texture: Fine.
b) Finish Texture: Medium.
c) Finish Texture: Extra Coarse.
4. Textured and Smooth Systems:
a. Textured (Waterbased Finish):
1) 1st Coat: S-W Loxon Concrete and Masonry Primer Sealer, LX02W50 (5.3-8.0 mils wet, 2.1-3.2 mils dry).
2) 2nd Coat: S-W Conflex UltraCrete Acrylic Textured Masonry Topcoat CF18W800 Series (50-80 sq ft/gal).
a) Finish Texture: Fine.
b) Finish Texture: Medium.
c) Finish Texture: Extra Coarse.
b. Textured Finish; Solvent Based:
1) 1st Coat: S-W UltraCrete Smooth Waterproofing Masonry Coating, B46 Series (100-160 sq ft/gal).
2) 2nd Coat: S-W Conflex UltraCrete Solvent Textured Waterproofing Masonry Coating, CF18W850 Series (50-80 sq ft/gal).
a) Finish Texture: Fine.
b) Finish Texture: Medium.
c) Finish Texture: Extra Coarse.
c. Smooth (Waterbased Finish):
1) 1st Coat: S-W Loxon XP, LX11W50 Series.
2) 2nd Coat: S-W Loxon XP, LX11W50 Series (14.0-18.0 mils wet; 6.4-8.3 mils dry per coat).
5. Stain System:
a. Solid Color Waterborne Finish:
1) 1st Coat: S-W Loxon Vertical Concrete Stain, LX31W50 Series. 2) 2nd Coat: S-W Loxon Vertical Concrete Stain, LX31W50 Series (50-250 sq/ft gal).
6. Clear Water Repellant:
a. Clear:
1) 1st Coat: S-W Conflex 7 percent Siloxane Water Repellant, CF31T7. 2) 2nd Coat: S-W Conflex 7 percent Siloxane Water Repellant, CF31T7 (50-200 sq ft/ gal).
B. Masonry: Concrete Masonry Units (CMU); Cinder or Concrete Block.
1. Latex Systems:
a. Gloss Finish:
SECTION G - Page 56
APPENDIX
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W A-100 Exterior Latex Gloss, A8 Series. 3) 3rd Coat: S-W A-100 Exterior Latex Gloss, A8 Series (4.0 mils wet, 1.3 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. (6.0-
12.0 mils wet, 2.0-4.0 mils dry per coat).
c. Satin Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W A-100 Exterior Latex Satin, A82 Series. 3) 3rd Coat: S-W A-100 Exterior Latex Satin, A82 Series (4.0 mils wet, 1.5 mils dry per coat).
d. Satin Finish Self Cleaning Upgrade:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Loxon Self Cleaning Acrylic Coating-Satin, LX14-50 Series.
3) 3rd Coat: S-W Loxon Self Cleaning Acrylic Coating-Satin, LX14-50 Series (5.0-7.0 mils wet, 2.0-2.8 dry per coat).
e. Flat Finish:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W A-100 Exterior Latex Flat, A6 Series.
3) 3rd Coat: S-W A-100 Exterior Latex Flat, A6 Series (4.0 mils wet, 1.2 mils dry per coat).
f. Flat Finish Self Cleaning Upgrade:
1) 1st Coat: S-W PrepRite Block Filler, B25W25 (75-125 sq ft/gal). 2) 2nd Coat: S-W Loxon Self Cleaning Acrylic Coating-Flat, LX13-50 Series.
3) 3rd Coat: S-W Loxon Self Cleaning Acrylic Coating-Flat, LX13-50 Series (5.0-7.0 mils wet, 2.0-2.8 dry per coat).
2. Elastomeric System:
a. Flat Finish:
1) 1st Coat: S-W Loxon BlockSurfacer, A24W00200 (16.0 mils wet, 8.8 mils dry).
2) 2nd Coat: S-W ConFlex XL Elastomeric High Build Coating, CF11W50 Series.
3) 3rd Coat: S-W ConFlex XL Elastomeric High Build Coating, CF11W50 Series (13.0-16.0 mils wet, 6.0-7.5 mils dry per coat). b. Flat Finish:
1) 1st Coat: S-W Loxon BlockSurfacer, LX01W200 (16.0 mils wet, 8.8 mils dry).
2) 2nd Coat: S-W Conflex SherLastic Elastomeric Masonry Coating, CF16W50 Series.
3) 3rd Coat: S-W Conflex SherLastic Elastomeric Masonry Coating, CF16W50 Series (10.0-14.0 mils wet, 4.0-6.0 mils dry per coat).
3. Textured Elastomeric System:
a. Textured Finish:
1) 1st Coat: S-W Loxon BlockSurfacer, LX01W200 (16.0 mils wet, 8.8 mils dry).
2) 2nd Coat: S-W ConFlex XL Elastomeric High Build Coating, CF11W50
SECTION G - Page 57
APPENDIX
Series (13.0-16.0 mils wet, 6.0-7.5 mils dry per coat). 3) 3rd Coat: S-W ConFlex XL Textured Elastomeric High Build Coating, CF15W50 Series (20 mils wet, 9.4 mils dry per coat).
a) Finish Texture: Fine.
b) Finish Texture: Medium.
c) Finish Texture: Extra Coarse.
4. Textured Masonry System:
a. Textured Finish; Waterbased:
1) 1st Coat: S-W Loxon BlockSurfacer, LX01W200 (16.0 mils wet, 8.8 mils dry).
2) 2nd Coat: S-W Conflex UltraCrete Acrylic Textured Masonry Topcoat CF18W800 Series (50-80 sq ft/gal).
a) Finish Texture: Fine.
b) Finish Texture: Medium.
c) Finish Texture: Extra Coarse.
b. Textured Finish; Solvent Based:
1) 1st Coat: S-W UltraCrete Smooth Waterproofing Masonry Coating, B46 Series (100-160 sq ft/gal).
2) 2nd Coat: S-W Conflex UltraCrete Solvent Textured Waterproofing Masonry Coating, CF18W850 Series (50-80 sq ft/gal).
a) Finish Texture: Fine.
b) Finish Texture: Medium.
c) Finish Texture: Extra Coarse.
c. Smooth Finish; Waterbased:
1) 1st Coat: S-W Loxon XP, LX11W50 Series.
2) 2nd Coat: S-W Loxon XP, LX11W50 Series (14.0-18.0 mils wet; 6.4-8.3 mils dry per coat).
5. Stain System:
a. Solid Color Waterborne Finish:
1) 1st Coat: S-W Loxon Vertical Concrete Stain, LX31W50 Series. 2) 2nd Coat: S-W Loxon Vertical Concrete Stain, LX31W50 Series (50-250 sq/ft gal).
6. Clear Water Repellant:
a. Clear Finish:
1) 1st Coat: S-W Conflex 7 percent Siloxane Water Repellant, CF31T7. 2) 2nd Coat: S-W Conflex 7 percent Siloxane Water Repellant, CF31T7 (50-200 sq ft/ gal).
C. Concrete: Non-Vehicular Floors, Patios, Porches, Steps and Platforms.
1. Acrylic System Water-Based:
a. Floor Finish:
1) 1st Coat: S-W Porch and Floor Enamel, A32-200 Series. 2) 2nd Coat: S-W Porch and Floor Enamel, A32-200 Series (4.0 mils wet,
1.5 mils dry per coat).
b. Floor Finish:
1) 1st Coat: S-W ConFlex Flexible Concrete Waterproofer-Smooth, CF14W50 Series.
2) 2nd Coat: S-W Conflex Flexible Concrete Waterproofer-Smooth, CF14W50 Series (10.0-12.0 mils wet per coat).
D. Metal: Aluminum, Galvanized.
SECTION G - Page 58
APPENDIX
1. Latex Systems:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series. 2) 2nd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series (2.0-4.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series. 2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 Series (2.0-
4.0 mils dry per coat).
c. Satin Finish:
1) 1st Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series. 2) 2nd Coat: S-W Pro Industrial Acrylic Eg-Shel, B66-660 Series (2.0-4.0 mils dry per coat).
d. Flat Finish:
1) 1st Coat: S-W A-100 Exterior Latex Flat, A6 Series.
2) 2nd Coat: S-W A-100 Exterior Latex Flat, A6 Series (4.0 mils wet, 1.2 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
E. Metal: Miscellaneous. Iron, Ornamental Iron, Structural Iron and Steel, Ferrous Metal.
1. Latex Systems:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0-10.0 mils wet, 1.8-3.6 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series. 3) 3rd Coat: S-W Pro Industrial Acrylic Gloss, B66-600 Series (2.0-4.0 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0-10.0 mils wet, 1.8-3.6 mils dry).
SECTION G - Page 59
APPENDIX
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 (2.0-4.0 mils dry per coat).
2. Alkyd Systems; Waterbased:
a. Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Gloss, B53-1050 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Semi-Gloss, B53-1150 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel SemiGloss, B53-1150 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat). c. Low Sheen Finish:
1) 1st Coat: S-W Pro Industrial Pro-Cryl Universal Primer, B66-1310 Series (5.0 mils wet, 2.0 mils dry).
2) 2nd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series.
3) 3rd Coat: S-W Pro Industrial Waterbased Alkyd Urethane Enamel Low Sheen, B53-1250 Series (4.0-5.0 mils wet, 1.4 - 1.7 mils dry per coat).
F. Wood: Decks, Exterior including pressure treated lumber, non-vehicular Floors, and Platforms.
1. Acrylic Water-Based Floor System:
a. Floor Finish:
1) 1st Coat: S-W Porch and Floor Enamel, A32-200 Series. 2) 2nd Coat: S-W Porch and Floor Enamel, A32-200 Series (4.0 mils wet;
1.5 mils dry per coat).
2. Stain Systems:
a. Solid Color Acrylic Latex:
1) 1st Coat: S-W SuperDeck Exterior Waterborne Solid Color Deck Stain, SD7-Series.
2) 2nd Coat: S-W SuperDeck Exterior Waterborne Solid Color Deck Stain, SD7-Series (200-400 sq ft/gal).
b. Semi-Solid Color Acrylic Latex:
1) 1st Coat: S-W SuperDeck Exterior Waterborne Semi-Solid Color Deck Stain, SD5-Series.
2) 2nd Coat: S-W SuperDeck Exterior Waterborne Semi-Solid Color Deck Stain, SD5-Series (100-350 sq ft/gal).
c. Semi-Transparent Stain:
1) 1st Coat: S-W SuperDeck Exterior Waterborne Semi-Transparent Stain, SD3TSeries.
2) 2nd Coat: S-W SuperDeck Exterior Waterborne Semi-Transparent Stain, SD3T Series (100 - 350 sq ft/gal).
d. Clear Stain:
1) 1st Coat: S-W SuperDeck Exterior Waterborne Clear Sealer,
SECTION G - Page 60
APPENDIX
SD1T00100.
2) 2nd Coat: S-W SuperDeck Exterior Waterborne Clear Sealer, SD1T00100, (150 - 300 sq ft/gal).
G. Wood: Siding, Trim, Shutters, Sashes, and Hardboard-Bare/Primed.
1. Latex Systems:
a. Gloss Finish:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W8041 (4.0 mils wet,
1.4 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Gloss, A8 Series. 3) 3rd Coat: S-W A-100 Exterior Latex Gloss, A8 Series (4.0 mils wet, 1.3 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W8041 (4.0 mils wet,
1.4 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 (2.0-4.0 mils dry per coat).
c. Satin Finish:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W8041 (4.0 mils wet,
1.4 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Satin, A82 Series. 3) 3rd Coat: S-W A-100 Exterior Latex Satin, A82 Series (4.0 mils wet, 1.5 mils dry per coat).
d. Satin Finish Self Cleaning Upgrade:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W8041 (4.0 mils wet,
1.4 mils dry).
2) 2nd Coat: S-W Loxon Self Cleaning Acrylic Coating-Satin, LX14-50 Series.
3) 3rd Coat: S-W Loxon Self Cleaning Acrylic Coating-Satin, LX14-50 Series (5.0-7.0 mils wet, 2.0-2.8 dry per coat).
e. Flat Finish:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W8041 (4 mils wet, 1.4 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Flat, A6 Series.
3) 3rd Coat: S-W A-100 Exterior Latex Flat, A6 Series (4.0 mils wet, 1.2 mils dry per coat).
f. Flat Finish Self Cleaning Upgrade:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W8041 (4 mils wet, 1.4 mils dry).
2) 2nd Coat: S-W Loxon Self Cleaning Acrylic Coating-Flat, LX13-50 Series.
3) 3rd Coat: S-W Loxon Self Cleaning Acrylic Coating-Flat, LX13-50 Series (5.0-7.0 mils wet, 2.0-2.8 dry per coat).
2. Stain; Water Reducible Systems:
a. Semi-Transparent:
1) 1st Coat: S-W WoodScapes Exterior Polyurethane Semi-Transparent Stain, A15T00005.
2) 2nd Coat: S-W WoodScapes Exterior Polyurethane Semi-Transparent Stain, A15T00005 (100-350 sq ft/gal).
b. Solid Color:
SECTION G - Page 61
APPENDIX
1) 1st Coat: S-W WoodScapes Exterior Acrylic Solid Color Stain, A15 Series.
2) 2nd Coat: S-W WoodScapes Exterior Acrylic Solid Color Stain, A15 Series (200-400 sq ft/gal).
H. Architectural PVC, Plastic, and Fiberglass:
1. Latex Systems:
a. Gloss Finish:
1) 1st Coat: S-W Extreme Bond Bonding Primer, B51W00150 (3.1 mils wet, 0.9 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Gloss, A8 Series. 3) 3rd Coat: S-W A-100 Exterior Latex Gloss, A8 Series (4.0 mils wet, 1.3 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Extreme Bond Bonding Primer, B51W00150 (3.1 mils wet, 0.9 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 (2.0-4.0 mils dry per coat).
c. Satin Finish:
1) 1st Coat: S-W Extreme Bond Bonding Primer, B51W00150 (3.1 mils wet, 0.9 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Satin, A82 Series. 3) 3rd Coat: S-W A-100 Exterior Latex Satin, A82 Series (4.0 mils wet, 1.5 mils dry per coat).
d. Flat Finish:
1) 1st Coat: S-W Extreme Bond Bonding Primer, B51W00150 (3.1 mils wet, 0.9 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Flat, A6 Series.
3) 3rd Coat: S-W A-100 Exterior Latex Flat, A6 Series (4.0 mils wet, 1.2 mils dry per coat).
I. Drywall: Gypsum Board and Exterior Drywall.
1. Latex Systems:
a. Gloss Finish:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W08041 (4.0 mils wet,
1.4 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Gloss, A8 Series. 3) 3rd Coat: S-W A-100 Exterior Latex Gloss, A8 Series (4.0 mils wet, 1.3 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W08041 (4.0 mils wet,
1.4 mils dry).
2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650. 3) 3rd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 (2.0-4.0 mils dry per coat).
c. Satin Finish:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W08041 (4.0 mils wet,
1.4 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Satin, A82 Series. 3) 3rd Coat: S-W A-100 Exterior Latex Satin, A82 Series (4.0 mils wet, 1.5
SECTION G - Page 62
APPENDIX
mils dry per coat).
d. Satin Finish Self Cleaning Upgrade:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W8041 (4.0 mils wet,
1.4 mils dry).
2) 2nd Coat: S-W Loxon Self Cleaning Acrylic Coating-Satin, LX14-50 Series.
3) 3rd Coat: S-W Loxon Self Cleaning Acrylic Coating-Satin, LX14-50 Series (5.0-7.0 mils wet, 2.0-2.8 dry per coat).
e. Flat Finish:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W08041 (4.0 mils wet,
1.4 mils dry).
2) 2nd Coat: S-W A-100 Exterior Latex Flat, A6 Series.
3) 3rd Coat: S-W A-100 Exterior Latex Flat, A6 Series (4.0 mils wet, 1.2 mils dry per coat).
f. Flat Finish Self Cleaning Upgrade:
1) 1st Coat: S-W Exterior Latex Wood Primer, B42W8041 (4 mils wet, 1.4 mils dry).
2) 2nd Coat: S-W Loxon Self Cleaning Acrylic Coating-Flat, LX13-50 Series.
3) 3rd Coat: S-W Loxon Self Cleaning Acrylic Coating-Flat, LX13-50 Series (5.0-7.0 mils wet, 2.0-2.8 dry per coat).
J. Vinyl Siding EIFS, Synthetic Stucco:
1. Latex Systems:
a. Gloss Finish:
1) 1st Coat: S-W A-100 Exterior Latex Gloss, A8 Series. 2) 2nd Coat: S-W A-100 Exterior Latex Gloss, A8 Series (4.0 mils wet, 1.3 mils dry per coat).
b. Semi-Gloss Finish:
1) 1st Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650. 2) 2nd Coat: S-W Pro Industrial Acrylic Semi-Gloss, B66-650 (2.0-4.0 mils dry per coat).
c. Satin Finish:
1) 1st Coat: S-W A-100 Exterior Latex Satin, A82 Series. 2) 2nd Coat: S-W A-100 Exterior Latex Satin, A82 Series (4.0 mils wet, 1.5 mils dry per coat).
d. Satin Finish Self Cleaning Upgrade:
1) 1st Coat: S-W Loxon Self Cleaning Acrylic Coating-Satin, LX14-50 Series.
2) 2nd Coat: S-W Loxon Self Cleaning Acrylic Coating-Satin, LX14-50 Series (5.0-7.0 mils wet, 2.0-2.8 dry per coat).
e. Flat Finish:
1) 1st Coat: S-W A-100 Exterior Latex Flat, A6 Series.
2) 2nd Coat: S-W A-100 Exterior Latex Flat, A6 Series (4.0 mils wet, 1.2 mils dry per coat).
f. Flat Finish Self Cleaning Upgrade:
1) 1st Coat: S-W Loxon Self Cleaning Acrylic Coating-Flat, LX13-50 Series.
2) 2nd Coat: S-W Loxon Self Cleaning Acrylic Coating-Flat, LX13-50 Series (5.0-7.0 mils wet, 2.0-2.8 dry per coat).
SECTION G - Page 63
APPENDIX
PART 4 EXECUTION
4.1 EXAMINATION
A. Do not begin installation until substrates have been properly prepared; notify Architect of unsatisfactory conditions before proceeding. If substrate preparation is the responsibility of another installer, notify Architect of unsatisfactory preparation before proceeding.
B. Proceed with work only after conditions have been corrected and approved by all parties, otherwise application of coatings will be considered as an acceptance of surface conditions.
C. Previously Painted Surfaces: Verify that existing painted surfaces do not contain lead based paints, notify Architect immediately if lead based paints are encountered.
4.2 SURFACE PREPARATION
A. General: Surfaces shall be dry and in sound condition. Remove oil, dust, dirt, loose rust, peeling paint or other contamination to ensure good adhesion.
1. Prior to attempting to remove mildew, it is recommended to test any cleaner on a small, inconspicuous area prior to use. Bleach and bleaching type cleaners may damage or discolor existing paint films. Bleach alternative cleaning solutions are advised.
2. Remove mildew before painting by washing with a solution of 1 part liquid household bleach and 3 parts of warm water. Apply solution and scrub the mildewed area. Allow solution to remain on the surface for 10 minutes. Rinse thoroughly with clean water and allow surface to dry before painting. Wear protective glasses or goggles, waterproof gloves, and protective clothing. Quickly wash off any of the mixture that comes in contact with your skin. Do not add detergents or ammonia to the bleach/water solution.
3. Remove items including but not limited to thermostats, electrical outlets, switch covers and similar items prior to painting. After completing painting operations in each space or area, reinstall items removed using workers skilled in the trades involved.
4. No exterior painting should be done immediately after a rain, during foggy weather, when rain is predicted, or when the temperature is below 50 degrees F (10 degrees C), unless products are designed specifically for these conditions. On large expanses of metal siding, the air, surface and material temperatures must be 50 degrees F (10 degrees F) or higher to use low temperature products.
B. Aluminum: Remove all oil, grease, dirt, oxide and other foreign material by cleaning per SSPC-SP1, Solvent Cleaning.
C. Block (Cinder and Concrete): Remove all loose mortar and foreign material. Surface must be free of laitance, concrete dust, dirt, form release agents, moisture curing membranes, loose cement, and hardeners. Concrete and mortar must be cured at least 30 days at 75 degrees F (24 degrees C). The pH of the surface should be between 6 and 9 unless the products are designed to be used in high pH environments. On tilt-up and poured-in-place concrete, commercial detergents and abrasive blasting may be necessary to prepare the surface. Fill bug holes, air pockets, and other voids with a cement patching compound.
D. Concrete, SSPC-SP13 or NACE 6: This standard gives requirements for surface preparation of concrete by mechanical, chemical, or thermal methods prior to the application of bonded protective coating or lining systems. The requirements of this standard are applicable to all
SECTION G - Page 64
APPENDIX
types of cementitious surfaces including cast-in-place concrete floors and walls, precast slabs, masonry walls, and shotcrete surfaces. An acceptable prepared concrete surface should be free of contaminants, laitance, loosely adhering concrete, and dust, and should provide a sound, uniform substrate suitable for the application of protective coating or lining systems.
E. Cement Composition Siding/Panels: Remove all surface contamination by washing with an appropriate cleaner, rinse thoroughly and allow to dry. Existing peeled or checked paint should be scraped and sanded to a sound surface. Pressure clean, if needed, with a minimum of 2100 psi pressure to remove all dirt, dust, grease, oil, loose particles, laitance, foreign material, and peeling or defective coatings. Allow the surface to dry thoroughly. The pH of the surface should be between 6 and 9 unless the products are designed to be used in high pH environments.
F. Copper and Stainless Steel: Remove all oil, grease, dirt, oxide and other foreign material by cleaning per SSPC-SP 2, Hand Tool Cleaning.
G. Exterior Composition Board (Hardboard): Some composition boards may exude a waxy material that must be removed with a solvent prior to coating. Whether factory primed or unprimed, exterior composition board siding (hardboard) must be cleaned thoroughly and primed with an alkyd primer.
H. Drywall - Exterior: Must be clean and dry. All nail heads must be set and spackled. Joints must be taped and covered with a joint compound. Spackled nail heads and tape joints must be sanded smooth and all dust removed prior to painting. Exterior surfaces must be spackled with exterior grade compounds.
I. Drywall - Interior: Must be clean and dry. All nail heads must be set and spackled. Joints must be taped and covered with a joint compound. Spackled nail heads and tape joints must be sanded smooth and all dust removed prior to painting.
J. Galvanized Metal: Clean per SSPC-SP1 using detergent and water or a degreasing cleaner to remove greases and oils. Apply a test area, priming as required. Allow the coating to dry at least one week before testing. If adhesion is poor, Brush Blast per SSPC-SP16 is necessary to remove these treatments.
K. Plaster: Must be allowed to dry thoroughly for at least 30 days before painting unless the products are designed to be used in high pH environments. Room must be ventilated while drying; in cold, damp weather, rooms must be heated. Damaged areas must be repaired with an appropriate patching material. Bare plaster must be cured and hard. Textured, soft, porous, or powdery plaster should be treated with a solution of 1 pint household vinegar to 1 gallon of water. Repeat until the surface is hard, rinse with clear water and allow to dry.
L. Steel: Structural, Plate, And Similar Items: Should be cleaned by one or more of the surface preparations described below. These methods are used throughout the world for describing methods for cleaning structural steel. Visual standards are available through the Society of Protective Coatings. A brief description of these standards together with numbers by which they can be specified follow.
1. Solvent Cleaning, SSPC-SP1: Solvent cleaning is a method for removing all visible oil, grease, soil, drawing and cutting compounds, and other soluble contaminants.
Solvent cleaning does not remove rust or mill scale. Change rags and cleaning solution frequently so that deposits of oil and grease are not spread over additional areas in the cleaning process. Be sure to allow adequate ventilation.
SECTION G - Page 65
APPENDIX
2. Hand Tool Cleaning, SSPC-SP2: Hand Tool Cleaning removes all loose mill scale, loose rust, and other detrimental foreign matter. It is not intended that adherent mill scale, rust, and paint be removed by this process. Before hand tool cleaning, remove visible oil, grease, soluble welding residues, and salts by the methods outlined in SSPC-SP1.
3. Power Tool Cleaning, SSPC-SP3: Power Tool Cleaning removes all loose mill scale, loose rust, and other detrimental foreign matter. It is not intended that adherent mill scale, rust, and paint be removed by this process. Before power tool cleaning, remove visible oil, grease, soluble welding residues, and salts by the methods outlined in SSPC-SP1.
4. White Metal Blast Cleaning, SSPC-SP5 or NACE 1: A White Metal Blast Cleaned surface, when viewed without magnification, shall be free of all visible oil, grease, dirt, dust, mill scale, rust, paint, oxides, corrosion products, and other foreign matter.
Before blast cleaning, visible deposits of oil or grease shall be removed by any of the methods specified in SSPC-SP1 or other agreed upon methods.
5. Commercial Blast Cleaning, SSPC-SP6 or NACE 3: A Commercial Blast Cleaned surface, when viewed without magnification, shall be free of all visible oil, grease, dirt, dust, mill scale, rust, paint, oxides, corrosion products, and other foreign matter, except for staining. Staining shall be limited to no more than 33 percent of each square inch of surface area and may consist of light shadows, slight streaks, or minor discoloration caused by stains of rust, stains of mill scale, or stains of previously applied paint. Before blast cleaning, visible deposits of oil or grease shall be removed by any of the methods specified in SSPC-SP1 or other agreed upon methods.
6. Brush-Off Blast Cleaning, SSPC-SP7 or NACE 4: A Brush-Off Blast Cleaned surface, when viewed without magnification, shall be free of all visible oil, grease, dirt, dust, loose mill scale, loose rust, and loose paint. Tightly adherent mill scale, rust, and paint may remain on the surface. Before blast cleaning, visible deposits of oil or grease shall be removed by any of the methods specified in SSPC-SP 1 or other agreed upon methods.
7. Power Tool Cleaning to Bare Metal, SSPC-SP11: Metallic surfaces that are prepared according to this specification, when viewed without magnification, shall be free of all visible oil, grease, dirt, dust, mill scale, rust, paint, oxide corrosion products, and other foreign matter. Slight residues of rust and paint may be left in the lower portions of pits if the original surface is pitted. Prior to power tool surface preparation, remove visible deposits of oil or grease by any of the methods specified in SSPC-SP1, Solvent Cleaning, or other agreed upon methods.
8. Near-White Blast Cleaning, SSPC-SP10 or NACE 2: A Near White Blast Cleaned surface, when viewed without magnification, shall be free of all visible oil, grease, dirt, dust, mill scale, rust, paint, oxides, corrosion products, and other foreign matter, except for staining. Staining shall be limited to no more than 5 percent of each square inch of surface area and may consist of light shadows, slight streaks, or minor discoloration caused by stains of rust, stains of mill scale, or stains of previously applied paint. Before blast cleaning, visible deposits of oil or grease shall be removed by any of the methods specified in SSPC-SP1 or other agreed upon methods.
9. High- and Ultra-High Pressure Water Jetting for Steel and Other Hard Materials:
SSPC-SP12 or NACE 5: This standard provides requirements for the use of high- and ultra-high pressure water jetting to achieve various degrees of surface cleanliness.
This standard is limited in scope to the use of water only without the addition of solid particles in the stream.
10. Water Blasting, SSPC-SP12/NACE No. 5: Removal of oil grease dirt, loose rust, loose mill scale, and loose paint by water at pressures of 2,000 to 2,500 psi at a flow
SECTION G - Page 66
APPENDIX
of 4 to 14 gallons per minute.
M. Vinyl Siding, Architectural Plastics, EIFS and Fiberglass: Clean vinyl siding thoroughly by scrubbing with a warm, soapy water solution. Rinse thoroughly. Do not paint vinyl siding with any color darker than the original color unless the paint system features SherwinWilliams VinylSafe technology. Painting with darker colors that are not Sherwin-Williams VinylSafe may cause siding to warp. Follow all painting guidelines of the vinyl manufacturer when painting. Only paint properly installed vinyl siding. Deviating from the manufacturer's painting guidelines may cause the warranty to be voided.
N. Stucco: Must be clean and free of any loose stucco. If recommended procedures for applying stucco are followed, and normal drying conditions prevail, the surface may be painted in 30 days. The pH of the surface should be between 6 and 9 unless the products are designed to be used in high pH environments such as Loxon.
O. Wood: Must be clean and dry. Prime and paint as soon as possible. Knots and pitch streaks must be scraped, sanded, and spot primed before a full priming coat is applied. Patch all nail holes and imperfections with a wood filler or putty and sand smooth.
4.3 INSTALLATION
A. Apply all coatings and materials with the manufacturer's specifications in mind. Mix and thin coatings according to manufacturer's recommendations.
B. Do not apply to wet or damp surfaces. Wait at least 30 days before applying to new concrete or masonry. Or follow manufacturer's procedures to apply appropriate coatings prior to 30 days. Test new concrete for moisture content. Wait until wood is fully dry after rain or morning fog or dew.
C. Apply coatings using methods recommended by manufacturer.
D. Uniformly apply coatings without runs, drips, or sags, without brush marks, and with consistent sheen.
E. Apply coatings at spreading rate required to achieve the manufacturers recommended dry film thickness.
F. Regardless of number of coats specified, apply as many coats as necessary for complete hide, and uniform appearance.
G. Inspection: The coated surface must be inspected and approved by the Architect just prior to the application of each coat.
4.4 PROTECTION
A. Protect finished coatings from damage until completion of project.
B. Touch-up damaged coatings after substantial completion, following manufacturer's recommendation for touch up or repair of damaged coatings. Repair any defects that will hinder the performance of the coatings.
END OF SECTION
SECTION G - Page 68
APPENDIX
Interior Lighting Specifications
Prudential Lighting or Approved Equal
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 PRULITE.COM 213.746.0360
O | Pendant & Surface
Pendant 1
07-07-2020
This is O.
It’s essentially the P4000’s (way more fun) twin. We’ve reinterpreted the popular original into a playful ring of light. It’s a donut-shaped O — as in the shape your mouth makes when you see it.
Type:
Job:
Lumen output may vary +/- 5%
See LED Details PDF for more info
4˝ aperture for all sizes,
5˝ body width
26˝, 37˝ or 475/8˝
5˝
LUMEN OUTPUT:
Direct (D1)
LO MO SO HO
O-20: Lumens 1050 1500 2100 2600
Watts 20 30 47 63
O-30: Lumens 1650 2140 3400 3850
Watts 30 41 75 89
O-40: Lumens 2200 2800 4600 5100
Watts 40 53 100 116
Click
here
Direct/Indirect (D9)
LO MO SO HO
O-20: Lumens 1550 2300 3400 4200
Watts 27 40 63 84
O-30: Lumens 2200 3000 5500 6500
Watts 42 57 105 125
O-40: Lumens 2650 3550 6750 7250
Watts 51 68 129 149
SE- RIESLED
COLOR
OUTPUT SHIELD- INGCOLOR/
FINISH
DISTRIBU- TIONCIRCUIT- INGVOLT- AGEMOUNTING CEILING
SYSTEMS
CONTROLS DRIVERS OPTIONS
O-20
2´ Dia.
O-30
3´ Dia.
O-40
4´ Dia.
TU
Tū Hue
Tunable
White
(2700K to
6500K)
LO
Low
MO
Medium
SO
Standard
HO
High
FWA
Flat
White
Acrylic
Lens
TMW
Textured
Matte
White
YGW
Gloss
White
(Standard)
Y__
Premium
Color
CC
Custom
Color
NOTE: All
canopies
are painted
the same
color as
the fixture
unless
specified
otherwis
D1 Direct
Solid Top
NOTE: Only 1
row of LEDs
D9
Semi-Direct
NOTE: ~17%
Uplight, 83%
Down. To
specify more
or less Uplight,
see Output
NOTE Recommended
distance to
hang from
ceiling to top of
fixture to avoid
hotspots; O-20:
18˝, O-30: 24˝,
O-40: 30˝
SC
Single
Circuit
DC
Dual
Circuit
(Two feeds
required, D9
only)
UNV
(120-
277)
SUR Surface Mount
(1˝ Standoff from ceiling)
CA48˝, 96˝ or 144˝
Aircraft Cable
(Adjustable)
3RPM48˝, 96˝ or
144˝ Round Cast
Aluminum Canopy
(Min from fixture to ceiling
2’ : 10˝, 3’: 16˝, 4˝; 20˝)
3SPM48˝, 96˝ or
144˝ Square Cast
Aluminum Canopy
(Min from fixture to ceiling
2’ : 10˝, 3’: 16˝, 4˝; 20˝)
MPCA48˝, 96˝
or 144˝
Monopoint
Mounting
(18˝ min from fixture to
ceiling)
SSC__ Top-Swivel Stem Mount
(Specify length)
X1 T-Bar
15/16˝ or 9/16˝ Exposed
(Standard)
Consult
factory for
9/16˝ Tegular
X3 Hard
Ceiling
X6 Slot
Grid or
Interlude
0-10V Uses
E10V Driver
DALI Uses
EDALI
Driver
DMX Uses
EDMX
Driver
nLight
Uses EDALI
Driver
E10V .1% 0-10V
DUALdrive,
EldoLED
(Dim to Dark [Off]
Tunable White)
EDALI DALI
DUALdrive,
EldoLED
(Dim to Dark [Off]
Tunable White)
EDMX
DMX
POWERdrive,
EldoLED
(Dim to Dark [Off]
Tunable White)
EMHE
CA T20
Emergency
Battery
(Remote only;
500 delivered
lumens; CA Title
20 compliant)
EM Emer- gency
Battery (3-4’:
400 delivered
lumens)
PruTune
Wall
Device
(EDALI driver
only, one
PruTune device
for each zone)
ETRAN
0-10V to
DALI Eldo
Translator
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 PRULITE.COM 213.746.0360
O | Pendant & Surface
Pendant 2
07-07-2020
D9 — SEMI-DIRECT
Standard Output:
O-20-TW-SO-D9
3184 Delivered Lumens
58 Watts
55 lm/w
4000 CCT
Test #L041502002
Zonal Lumen Summary:
0-90 = 61%
90-180 = 39% 635
Verti- cal
Angle
0 25 45 65 90
0 685 685 685 685 685
5 682 682 682 682 682
15 654 654 654 654 654
25 816 816 817 817 817
35 604 604 604 603 603
45 446 446 445 444 443
55 347 346 345 344 344
65 241 241 240 239 239
75 172 172 172 172 172
85 39 39 39 38 39
90 0 0 0 0 0
95 15 15 15 15 16
115 143 144 143 141 141
125 216 217 215 213 212
135 290 290 289 287 286
145 360 360 359 357 356
155 422 422 421 418 416
165 468 469 468 464 463
175 486 486 484 480 479
180 496 496 496 496 496
D1 — DIRECT
High Output:
O-30-LED4-HO-D1
5290 Delivered Lumens
97 Watts
55 lm/w
4000 CCT
Test
#103619833LAX-001
Zonal Lumen Summary:
0-90 = 100% 1848
Vertical
Angle 0 25 45 65 90
0 1848 1848 1848 1848 1848
5 1837 1838 1838 1838 1840
15 1766 1763 1765 1769 1772
25 1070 1070 1070 1070 1070
35 937 937 937 937 937
45 1437 1434 1438 1445 1452
55 927 926 935 944 955
65 639 640 648 657 667
75 354 352 362 371 380
85 90 87 92 99 105
90 0 0 0 0 0
LUMEN MAINTENANCE
L70 (LO, MO, SO) — 100,000+ Hours
L70 (HO) — 90,000+ Hours
LED SYSTEM LED modules and drivers are field replaceable.
CONTROLS Tunable White can be controlled via the following methods:
— 0-10V: Control brightness and color independently
via 2 dimmers.
— DALI: For more precise control. Prudential’s PruTune wall control includes a color wheel, dimming indicator and six preset color options (2700K, 3000K, 3500K, 4000K, 5000K & 6500K).
— nLight*: Similar to DALI but with easier installation. — DMX*: Recommended for dynamic lighting.
* Both nLight and DMX have Plug-n-Play connectors installed on the fixture NOTE: Independent control of Up and Down light (dual circuit) requires doubling the above controls for 0-10V and DALI (Four dimmers or two PruTune, or similar, devices). Dual circuit on DMX and nLight is handled via addressing of connected components. Mixing control options is not recommended.
LABELS CSA and ETL damp labeled and I.B.E.W. manufactured.
CONSTRUCTION
Housing Extruded aluminum, rolled and welded, >25% PC recycled, 100% recyclable
Lens Flat acrylic, 100% recyclable.
Weights O-20: 17lbs O-30: 27lbs O-40: 34lbs
MOUNTING Surface or suspended by aircraft cables, top-swivel stems.
WARRANTY Single-source, 5 year limited warranty covers standard components and construction. See warranty for more details.
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 PRULITE.COM 213.746.0360
O | Pendant & Surface
Pendant 3
07-07-2020
YSW – Seashell White
(Matte)
YCH – Champagne (Metallic)
YSL – Silver (Metallic) YPE – Pewter (Matte)
YRG – Rain Grey (Gloss) YSTM – Storm Grey (Matte)
YBK – Black (Matte) YBB – Black (Semi Gloss)
YSKM – Sky (Matte) YMB – Military Blue (Matte)
YIB – Interstate Blue (Matte) YSAM – Sapphire (Matte)
For paint chip samples, please email:
[email protected]
Choose from one of our Premium
Colors with no set-up fee.
YFGM – Forest Green (Matte) YBR – Bronze (Matte)
YSRM – Sunset Red (Matte) YBY – Boysenberry (Matte)
YOR – Orange (Matte) YDAM – Daffodil (Matte)
MOUNTING LOCATIONS
120˚ 120˚ 120˚
MOUNTING DIMENSIONS
SIZE DIM. A (SUR / STEM) DIM. B (CABLE)
“O”-20 18 1/8˝ 17˝
“O”-30 27 23/32” 29 9/16˝
“O”-40 36 15/16˝ 35 25/32˝
DIM A
DIM A
DIM A
DIM B
DIM B
DIM B
26˝ Dia.
37˝ Dia.
47 1/2˝ Dia.
DIM A
DIM A
DIM B
DIM B
DIM A
DIM B
DIM A
DIM B
DIM A
DIM
DIM
B
A
DIM B
0-20 0-30 0-40
24”, 36” or 48"
O LED Spec Illos
5⁄8˝
½˝
24”, 36” or 48"
5”
O LED Spec Illos
MPCA: 3 Cables min
18˝ from Ceiling
CA or SSC: (3) 5˝ Canopies
MOUNTING OPTIONS
3RPM48˝, 96˝ or 144˝: Round Cast Aluminum Canopy
3SPM: 2’, 3’, 4’ (3 Cables)
3SPM48˝, 96˝ or 144˝: Round Cast Aluminum Canopy
3SPM: 2’, 3’, 4’ (3 Cables)
15/8˝
61/2˝
DIMENSIONS
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 PRULITE.COM 213.746.0360
O | Pendant & Surface
Pendant 4
07-07-2020
6500K
5700K
5000K
4500K
4000K
3500K
3000K
2700K
BLACK
BODY
CURVE
LIGHT OUTPUT AND COLOR
— Actual CCT is below targeted, especially in cooler range as a function of LED chip
— Light output is held constant over full color range and output matches static white PRU fixtures for easy specification (Low, Medium, Standard and High output), see spec sheets for delivered lumens for individual fixtures (varies). Lumen output may vary +/- 5%
ELECTRICAL
0-10V:
— Universal Input Voltage (120-277VAC)
— 0.1% Dimming
— Controlled by two individual 0-10V signals, one for light output (to 1%), the other for adjusting CCT (2700K-6500K)
— 50,000 hours rated life at 70˚C max driver case temperature — 87% efficiency — THD <20% — PF >0.9
DALI:
— Universal Input Voltage (120-277VAC)
— DALI control system (by others) or PRUTune DALI wall device to control color temperature and brightness
NOTE: PRUTune wall device only requires Purple & Grey wires common to 0-10v wiring, ideal for control of individual spaces — 50,000 hours rated life at 70˚C max driver case temperature — 87% efficiency — THD <20% — PF >0.9
DMX:
— Universal Input Voltage (120-277VAC)
— DMX control system (by others) for control of CCT and brightness — DMX drivers have multiple output channels that can be independently addressed at the factory
— 50,000 hours rated life at 70˚C max driver case temperature — 86% efficiency — THD <20% — PF >0.9
40.000
35.000
30.000
25.000
20.000
15.000
5.000
10.000
0.000
350 400 450 500 550 600 650 700 750 800
(mW/nm)
Nanometers
2700K 3500K 6500K
TARGETED
CCT
TESTED
CCT LUMEN OUTPUT TOTAL POWER (W) CRI R9 DUV
6500 6100 + 2% - 11% 96 96 0
5000 4675 STATED LUMENS ON
LUMEN CHART - 14% 95 96 - 0.005
4000 3675 + 2% - 13% 94 85 - 0.007
3500 3225 + 1% - 12% 93 74 - 0.006
3000 2875 STATED LUMENS ON
LUMEN CHART - 6% 93 57 - 0.004
2700 2650 - 2% STATED WATTS ON
LUMEN CHART 91 46 - 0.002
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 PRULITE.COM 213.746.0360
O | Pendant & Surface
Pendant 5
07-07-2020
P R U T U N E WA L L D E V I C E
PRUTune DALI device includes:
— Easy-to-understand user control with intuitive design — Out-of-the-box set-up, no commissioning needed
— Color wheel for color change from 2700K to 6500K
— Dimming to 0.1% (255 Steps)
— Six preset colors (2700K, 3000K, 3500K, 4000K, 5000K, 6500K) — Must use DALI driver, consult factory to control non-Prudential Ltg Tunable White fixtures
— Control one (1) zone - up to 30 drivers
(Consult factory for fixture quantity dependant upon fixture type, size & output) PRUTune + EMHE: — Prutune does not have memory
— Once normal power is restored, the controller sends a signal of 100% intensity and 6500K CCT BRIGHTNESS: 0.1%-100%
POWER INDICATOR
RED : OFF
BLUE : ON
COLOR WHEEL
ON / OFF
PRESET COLOR TEMPERATURES
EXPLODED VIEW
Ensure arrows are aligned when
assembling ‘Pru wall device’
PRULITE.COM 213.746.0360
O | Pendant & Surface
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 Pendant 6 07-07-2020
— Six Wire Cord for Data & Power 0-10V Dimmer Control
CCT (Color)
0-10V Dimmer Control
Intensity (Brightness) & Power
CCT +
INT +
CCT -
INT -
LINE BLACK
NEUTRAL WHITE
— Cords (Power and Data) between fixture and junction box are supplied by Prudential, but ship separately.
Wire colors shown below are representative of the wires inside the fixture. — Junction box wiring by others. Wire colors shown are for illustration purposes only.
LINE BLACK
NEUTRAL WHITE
D1/D9 – SC – 0-10v
Single Control for Color, Single Control for Intensity
LIGHTING FIXTURE INTERNAL DETAILS:
Output 1– : BLUE
Output 2– : BLUE / WHITE
Output 1+ : RED
Output 2+ : RED / WHITE
0-10V DRIVER
TUNABLE WHITE
LED BOARD
J-BOX WIRING DETAIL:
LINE BLACK LINE BLACK
NEUTRAL WHITE NEUTRAL WHITE
GROUND GREEN GROUND GREEN DATA & POWER CORD
INT+
INT–/CCT–
INT+ BLUE
CCT+ RED
INT-/CCT- ORANGE
CCT+
BLUE PURPLE
ORANGE GREY
RED PURPLE/BLACK
GREY/BLACK
PRULITE.COM 213.746.0360
O | Pendant & Surface
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 Pendant 7 07-07-2020
DOWNLIGHT
D9 – DC – 0-10v
Dual Control for both Color & Intensity (Control Up/Down separately) — (2x) Six Wire Cord for Data 0-10V Dimmer Control
CCT (Color)
0-10V Dimmer Control
CCT (Color)
0-10V Dimmer Control
Intensity (Brightness)
& Power
0-10V Dimmer Control
Intensity (Brightness)
& Power
— Cord (Power and Data) between fixture and junction box are supplied by Prudential, but ship separately.
Wire colors shown below are representative of the wires inside the fixture. — Junction box wiring by others. Wire colors shown are for illustration purposes only. 2 CORDS REQUIRED
CCT +
INT +
CCT -
INT -
CCT +
INT +
CCT -
INT -
LINE BLACK
LINE BLACK
NEUTRAL WHITE
NEUTRAL WHITE
LIGHTING FIXTURE INTERNAL DETAILS:
Output 1– : BLUE
Output 2– : BLUE / WHITE
Output 1+ : RED
Output 2+ : RED / WHITE
0-10V DRIVER
TUNABLE WHITE
LED BOARD
J-BOX WIRING DETAIL:
LINE BLACK LINE BLACK
NEUTRAL WHITE NEUTRAL WHITE
GROUND GREEN GROUND GREEN DATA & POWER CORD
INT+
INT–/CCT–
INT+ BLUE
CCT+ RED
INT-/CCT- ORANGE
CCT+
BLUE PURPLE
ORANGE GREY
RED PURPLE/BLACK
GREY/BLACK
UPLIGHT
PRULITE.COM 213.746.0360
O | Pendant & Surface
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 Pendant 8 07-07-2020
DATA SH
D9 – DC – 0-10v
Single Control for Color, Dual Control for Intensity
UPLIGHT & DOWNLIGHT
0-10V Dimmer Control
CCT (Color)
0-10V Dimmer Control
Intensity (Brightness)
& Power
0-10V Dimmer Control
Intensity (Brightness)
& Power
DOWNLIGHT
LINE BLACK
NEUTRAL WHITE
CCT +
INT +
INT +
CCT -
INT -
INT -
— Cord (Power and Data) between fixture and junction box are supplied by Prudential, but ship separately.
Wire colors shown below are representative of the wires inside the fixture. — Junction box wiring by others. Wire colors shown are for illustration purposes only.
UPLIGHT
2 CORDS REQUIRED
LINE BLACK
NEUTRAL WHITE
— (2x) Six Wire Cord
for Data & Power
LIGHTING FIXTURE INTERNAL DETAILS:
Output 1– : BLUE
Output 2– : BLUE / WHITE
Output 1+ : RED
Output 2+ : RED / WHITE
0-10V DRIVER
TUNABLE WHITE
LED BOARD
J-BOX WIRING DETAIL:
LINE BLACK LINE BLACK
NEUTRAL WHITE NEUTRAL WHITE
GROUND GREEN GROUND GREEN DATA & POWER CORD
INT+
INT–/CCT–
INT+ BLUE
CCT+ RED
INT-/CCT- ORANGE
CCT+
BLUE PURPLE
ORANGE GREY
RED PURPLE/BLACK
GREY/BLACK
PRULITE.COM 213.746.0360
O | Pendant & Surface
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 Pendant 9 07-07-2020
PruTune Wall Device
or Other DALI Controller
ON/OFF
CCT
nLight
SUPPLY
POWER
nPS80
FRONT:
BACK:
DALI
Signal
Output
100-240C
Input
DA+
L
DAN
D1/D9 –SC – DALI – PruTune
Single Control for Color & Intensity
— Six Wire Cord for Data & Power
J-BOX WIRING DETAIL:
DATA & POWER
LINE BLACK
CORD
NEUTRAL WHITE
GROUND GREEN
— Cord (Power and Data) between fixture and junction box are supplied by Prudential, but ship separately.
Wire colors shown below are representative of the wires inside the fixture. — Junction box wiring by others. Wire colors shown are for illustration purposes only. 1 CORD REQUIRED
LIGHTING FIXTURE INTERNAL DETAILS:
DALI DRIVER
TUNABLE WHITE
LED BOARD
Output 1 – : BLUE
Output 2 – : BLUE / WHITE
Output 1+ : RED
Output 2+ : RED / WHITE LINE BLACK
DALI + BLUE DALI + BLUE
DALI – RED DALI – RED
NEUTRAL WHITE
GROUND GREEN
SHIELD
nLi
POW
DA–
DA+
LINE BLACK
LINE BLACK
NEUTRAL WHITE
NEUTRAL WHITE
ORANGE NOT USED
PRULITE.COM 213.746.0360
O | Pendant & Surface
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 Pendant 10 07-07-2020
PruTune Wall Device
or Other DALI Controller
D9 –DC – DALI – PruTune
Single Control for Color & Intensity Down, Separate Control for Color & Intensity Up
DOWNLIGHT
UPLIGHT
LINE RED
NEUTRAL WHITE
LINE BLACK
LIGHTING FIXTURE INTERNAL DETAILS:
TUNABLE WHITE
LED BOARD
NEUTRAL WHITE
GROUND GREEN
Output 1– : BLUE
Output 2– : BLUE / WHITE
Output 1+ : RED
Output 2+ : RED / WHITE
DALI–
DALI–
DALI+
DALI+
— Cord (Power and Data) between fixture and junction box are supplied by Prudential, but ship separately.
Wire colors shown below are representative of the wires inside the fixture. — Junction box wiring by others. Wire colors shown are for illustration purposes only.
LINE BLACK
OR LINE RED
2 CORDS REQUIRED
ON/OFF
CCT
nLight
SUPPLY
POWER
nPS80
BACK:
DALI
Signal
Output
100-240C
Input
DA+
L
DAN
J-BOX WIRING DETAIL:
DALI + BLUE
DALI – RED
LINE BLACK
NEUTRAL WHITE
LINE RED
— (2x) Six Wire Cord
for Data & Power
DATA & POWER
LINE BLACK
CORD
NEUTRAL WHITE
GROUND GREEN
DALI + BLUE
DALI – RED
ORANGE NOT USED
DALI DRIVER
PRULITE.COM 213.746.0360
O | Pendant & Surface
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 Pendant 11 07-07-2020
DATA SHIELD
PRULITE.COM 213.746.0360
DMX CONNECTOR DETAIL:
MALE: DMX IN
FEMALE: DMX OUT
D1/D9 – SC – DMX
DMX Control of Color & Intensity TUNABLE WHITE
LED BOARD
2700K Warm
6500K Cool
DMX
DATA
SHIELD
LED Output 2-
LED Output 2+
LED Output 1-
LED Output 1+
J-BOX
J-BOX WIRING DETAIL:
DMX CONNNECTIONS
Bare Metal
Drain Wire
(SHIELD)
MUST NOT
TOUCH
J-BOX!
(Heat shrink
REQUIRED)
To next fixture
— Three Wire Power
— (2x) DMX Cable for Data
TUNABLE WHITE
LED BOARD
2700K Warm
6500K Cool
DMX
DATA
SHIELD
LED Output 2-
DATA SHIELD
LED Output 2+
LED Output 1-
LED Output 1+
J-BOX
LED
CODE
DMX/RS-485 BELDEN 9841 OR EQUIVALENT
Output 1– : BLUE
Output 2– : BLUE / WHITE
Output 1+ : RED
Output 2+ : RED / WHITE
8 PIN CONNECTOR DETAIL:
8 PIN
CONNECTOR
TUNABLE
WHITE
LED BOARD
LINE BLACK
LINE BLACK
LINE BLACK
NEUTRAL WHITE
NEUTRAL WHITE
NEUTRAL WHITE
GROUND GREEN
DMX IN SHIELD
DMX IN –
NOT USED
DMX IN +
POWER
CORD
— Dual Circuit is handled via addressing the drivers
(an extra data cord is not required)
— Power cord between fixture and Junction Box is supplied by Prudential, but ship separately. Wire colors correspond to supplied cords. — Junction box wiring by others.
— DMX cables, with 3-pin connectors, by others.
FOR MULTIPLE
FIXTURES
SEE NEXT PAGE
3 CORDS REQUIRED
LINE BLACK
NEUTRAL WHITE
GROUND GREEN
DMX DRIVER
DMX –
DMX –
Shield
Shield
DMX +
DMX +
PRULITE.COM 213.746.0360
O | Pendant & Surface
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 Pendant 12 07-07-2020
DMX CONTROLLER
(BY OTHERS)
FIRST DMX FIXTURE
NEXT DMX FIXTURE
LAST DMX FIXTURE
RECOMMENDATIONS
— Fixtures must be daisy chained. (Drivers internal to fixture and daisy chained) — Maximum 32 drivers per controller, consult factory for quantity of drivers per fixture.
If more than 32 drivers a DMX booster / repeater (by others) must be used. — Keep DMX cable less than 1000ft between controller and end of line resistor. — Cables connecting fixtures must be designed for DMX/RS-485, Beldin 9841 or equivalent. — If more than one zone, fixtures per zone must be specified. 120 OHM END OF LINE RESISTOR
(BY OTHERS)
IN
IN
IN
OUT
OUT
OUT
D1/D9 – SC – DMX
DMX Control of Color & Intensity, Multiple Fixtures
PRULITE.COM 213.746.0360
O | Pendant & Surface
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 Pendant 13 07-07-2020
ON/OFF
CCT
nLight
POWER
SUPPLY
nPS80
RJ45 CONNECTOR DETAIL:
SC – nLight
(nLight Control of Color & Intensity, One Fixture)
— Three Wire Power
— (2x) CAT5e for Data
BLACK
WHITE
WALL POD
LIGHTING FIXTURE INTERNAL DETAILS:
LED
CODE
LINE
NEUTRAL
GROUND
DALI DRIVER TUNABLE WHITE
LED BOARD
CAT 5e:
LED CODE +
LED CODE –
Output 1– : BLUE
Output 2– : BLUE / WHITE
Output 1+ : RED
Output 2+ : RED / WHITE
— Cords (Power and Data) between fixture and Junction Box are supplied by Prudential, but ship separately. Wire colors correspond to supplied cords. — Wiring from Junction Box to Controllers is by others.
Wire colors are for illustration purposes only.
— CAT5e cables by others.
3 CORDS REQUIRED
...To next fixture
NIO EZDCL CCT
BY OTHERS
PRULITE.COM 213.746.0360
O | Pendant & Surface
Prudential Ltg. reserves the right to change design specifications or materials without notice. Please visit prulite.com for most current data. © 2014 All rights reserved – All products manufactured at: Prudential Ltg. 1774 E. 21st Street, Los Angeles, CA 90058 Pendant 14 07-07-2020
ON/OFF
CCT
nLight
POWER
SUPPLY
nPS80
SC – nLight
(nLight Control of Color & Intensity, Multiple Fixtures)
TYPICAL NETWORK LAYOUT
WALL POD
BY OTHERS
Power
Control Signal
Via CAT 5e
— All nLight RJ45 ports are interchangeable (no dedicated IN or OUT). — nLight zones must have a net positive amount of bus power. See table below for bus power consumption as a function of fixture size and output. Bus power is supplied by power/relay packs (nPP16 family and nPS80), power supplies (PP20 PL BP and nPANELS), nLight enabled fixtures, and bridges.
3 CORDS REQUIRED
BUS POWER CONSUMPTION
LO MO SO HO
D1 D9 SC DC D1 D9 SC DC D1 D9 SC DC D1 D9 SC DC
O-20
3mA
N/A
3mA 6mA
6mA
O-20 6mA 3mA 9mA
6mA 6mA
3mA
9mA
O-20
SECTION G - Page 1
APPENDIX
APPENDIX A
ROOF LOCATION MAP
ROOF "B-1"
COMMUNITY CENTER
- ANGLED ROOF
ROOF "C-2"
ACTIVITY ROOMS -
FLAT ROOF WITH
EXISTING A/C
ROOF "D"
CRAFTS ROOMS
ROOF "C-1" ROOF "B-3"
ACTIVITY ROOMS COMMUNITY CENTER
- ANGLED ROOF
ROOF "E"
MAINTENANCE GARAGE
ROOF "A-1"
TEEN CENTER
-ALL ANGLED ROOFS
ROOF "A-2"
TEEN CENTER
-FLAT ROOF
ROOF "B-2"
COMMUNITY CENTER
- FLAT ROOF WITH
EXISTING EQUIPMENT
ROOF "B-4"
COMMUNITY CENTER
-ANGLED ROOF Page 473 of 517
SECTION G - Page 2
APPENDIX
APPENDIX B
CONSTRUCTION DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
WALL WATERPROOFING MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
MEMBRANE ROOFING DETAILS
COPYRIGHT © 2015 TILE ROOFING INSTITUTE/WSRCA Uniform ES ER-2015 01/2000 Revised 7/2015 Appendix A
TRI/WSRCA 17
TILE ROOF DETAIL
COPYRIGHT © 2015 TILE ROOFING INSTITUTE/WSRCA Uniform ES ER-2015 01/2000 Revised 7/2015 18 TRI/WSRCA Appendix A
TILE ROOF DETAIL
COPYRIGHT © 2015 TILE ROOFING INSTITUTE/WSRCA Uniform ES ER-2015 01/2000 Revised 7/2015 TRI/WSRCA 29
TILE ROOF DETAIL
COPYRIGHT © 2015 TILE ROOFING INSTITUTE/WSRCA Uniform ES ER-2015 01/2000 Revised 7/2015 Appendix A
TRI/WSRCA 39
TILE ROOF DETAIL
COPYRIGHT © 2015 TILE ROOFING INSTITUTE/WSRCA Uniform ES ER-2015 01/2000 Revised 7/2015 54 TRI/WSRCA Appendix A
TILE ROOF DETAIL
COPYRIGHT © 2015 TILE ROOFING INSTITUTE/WSRCA Uniform ES ER-2015 01/2000 Revised 7/2015 Appendix A
TRI/WSRCA 59
TILE ROOF DETAIL
COPYRIGHT © 2015 TILE ROOFING INSTITUTE/WSRCA Uniform ES ER-2015 01/2000 Revised 7/2015 Appendix A
TRI/WSRCA 61
TILE ROOF DETAIL
Dimensional Data (inches and [ mm ]) are Subject to Manufacturing Tolerances and Change Without Notice
SPECIFICATION SHEET
TAG _______
* Regularly furnished unless otherwise specified.
Zurn Industries, LLC | Specification Drainage Operation 1801 Pittsburgh Avenue, Erie, PA U.S.A. 16502 · Ph. 855-663-9876, Fax 814-454-7929 In Canada | Zurn Industries Limited
3544 Nashua Drive, Mississauga, Ontario L4V 1L2 · Ph. 905-405-8272, Fax 905-405-1292 www.zurn.com
Z163
15 [381] DIAMETER COMBINATION MAIN ROOF &
OVERFLOW DRAIN W/ LOW SILHOUETTE DOMES &
DOUBLE TOP-SET® DECK PLATE
ENGINEERING SPECIFICATION: ZURN Z163
15" [381 mm] Diameter roof drain and overflow drain, Dura-Coated cast iron bodies with combination membrane flashing clamp/gravel guards, double Top-Set® deck plate, and low silhouette PolyDomes.
OPTIONS (Check/specify appropriate options)
PIPE SIZE (Specify size/type) OUTLET E BODY HT. DIM.
3, 4, 6 [51, 76, 152] _____ IC Inside Caulk 5-1/4 [133] 2, 3, 4, 6, 8 [51, 76, 102, 152, 203] _____ IP Threaded 3-3/4 [95] 2, 3, 4, 6, 8 [51, 76, 102, 152, 203] _____ NH No-Hub 5-1/4 [133] 2, 3, 4 [51, 76, 102] _____ NL Neo-Loc 4-5/8 [117]
PREFIXES
____ Z D.C.C.I. Body with Poly-Dome*
____ ZA D.C.C.I. Body with Aluminum Dome
____ ZC D.C.C.I. Body with Cast Iron Dome
6 [152]
73 [33]
74 [34]
2, 3, 4 [51, 76, 102]
Approx.
Wt. Lbs.
[kg]
Dome Open Area
Sq. In. [cm2] A - Pipe Size
In.[mm]
103 [665]
8 [203] 75 [34]
SUFFIXES
____ -AR Acid Resistant Epoxy Coated Finish
____ -DE Deck Extension
____ -DR Top-Set® Drain Riser
____ -E Static Extension 1 thru 4 [25 thru 102] (Specify Ht.) ____ -EA Adjustable Extension Assembly
2-1/8 thru 3-1/2 [54 thru 89]
____ -G Galvanized Cast Iron
____ -HD 6-3/4 [171] High Aluminum Dome Strainer
(148 in² [955 cm²] Open Area)(ZA Only)
____ -SC Secondary Clamping Collar
____ -SS Stainless Steel Mesh Screen Over Dome
___ -TC Neo-Loc Test Cap Gasket
(2,3,4 [51,76,102] NL Bottom Outlet Only)
____ -VP Vandal Proof Secured Top
____ -W3 3 [76] Internal Water Dam
____ -W4 4 [102] Internal Water Dam
____ -XJ Vertical Expansion Joint (See Z190)
____ -84 Stainless Steel Perforated Gravel Guard
____ -85 Stainless Steel Perforated Extension
____ -89 2 [51] High External Water Dam
(Replaces Internal Dam)
Rev. G
Date: 02/28/18
C.N. No. 139682
Prod. | Dwg. No. Z163
City of Los Alamitos
CITY COUNCIL AGENDA REPORT
MEETING DATE: October 23, 2023 ITEM NUMBER: 12I
To: Mayor Tanya Doby & Members of the City Council
Presented By: Irving Montenegro Jr., Manager
Ron Noda, Development Services Director
Subject: Award Sterns Park Playground and Fitness Equipment Purchase
SUMMARY
This item is for the purchase of playground and fitness equipment directly from the manufacturer, GameTime, through the use of a cooperative purchasing agreement via OMNIA Partners. The purchase of the playground and fitness equipment is part of the Sterns Park Rehab Project and would enable greater cost savings and assurance that the project continues forward on its intended timeline.
RECOMMENDATION
1. Review and discuss the proposal and purchasing agreement for GameTime playground and fitness equipment; and,
2. Authorize the City Manager to use a cooperative purchasing agreement, in a form approved by the City Attorney, for the playground and fitness equipment in the amount of $239,899,85.
BACKGROUND
The City of Los Alamitos has contracted with Hirsch and Associates, Inc. for the architectural design and project management of the Capital Improvement Project (CIP) - Sterns Park Rehab Project. The Parks, Recreation, and Cultural Arts Commission was presented with different playground, fitness, and park amenity designs, ultimately recommending to proceed with items from GameTime as a favorable and highly reputable industry manufacturer. In order to ensure product inventory availability and maximize cost savings associated with the project, the staff recommends using a cooperative purchase agreement for the playground and fitness equipment.
DISCUSSION
Cooperative purchase agreements enable cities to maximize cost savings and staff resources by sharing contracting (piggy back) and purchasing efforts with other government agencies.
Utilizing cooperative purchasing agreements is advantageous to the City because it provides an opportunity for the City to obtain lower pricing through volume purchasing. It is often more cost effective to eliminate the cost and time spent on these administrative processes and purchase items and services through a cooperative purchasing program. As cooperative agreements reach expiration, they are automatically renewed, allowing government agencies to continue to leverage cost savings.
OMNIA Partners is among the leading national government purchasing cooperatives, providing world class government procurement resources and solutions to local and state government agencies, school districts (K-12), higher education institutions, and nonprofits looking for the best overall supplier government pricing. OMNIA Partners works with many governmental agencies to offer cooperative purchasing contracts to other governmental agencies in order to create a more economical means of procuring services and supplies, an ability to pay less for products and services, and reducing the administrative costs of developing contracts.
Under Section 2.60.110 of the Los Alamitos Municipal Code (LAMC), the City’s purchasing ordinance allows the City to “piggy back” off another public agency or government entity, which has selected the vendor using competitive bidding procedures substantially the same as or similar to those normally utilized by the City for the acquisition of such materials, supplies, equipment, or services. If such a determination is made, the City Manager or City Council, as applicable, may proceed to purchase the materials, supplies, equipment or services at a price equivalent to that offered to the acquiring agency.
As a member of OMNIA Partners, the City has the ability to utilize its service of awarded contracts including unlimited expert assistance to answer any questions, help connect the City directly to suppliers, and help find solutions that will best suit the City’s needs. The City’s membership ID # is: 4001692, which provides access to connect to any contract in a portfolio that contains over 500 vendors.
OMNIA Partners is currently used by several city agencies regionally throughout the state and locally across Orange County. Some of these partner agencies include: City of La Palma, City of Laguna Beach, City of Brea, City of Fountain Valley, City of San Clemente, among others.
The County of Orange is also an active member of OMNIA Partners.
FISCAL IMPACT
The proposal for the purchase of the playground and fitness equipment is currently listed as $239,899.85, which includes a 20% discount off the standard rate, which is primarily due to the membership price of using OMNIA Partners. Funding for the Sterns Park Project's equipment will be taken from fiscal year 2023/24, account number 10-570-5501.2303.
Attachment: 1. Sterns Park Playground Option 2
Proposal for
Hirsch & Associates Inc.
Prepared by
10-03-2023
Job # 109292-01
City of Los Alamitos - Sterns Park Playground Option 2
805-910-5971 | www.gwpark.com
Total Elevated Play Components
Total Different Types Of Ground Level ComponentsTotal Accessible Ground Level Components ShownTotal Elevated Components Accessible By TransferTotal Elevated Play Components Accessible By Ramp Representative
This play
equipment is recommended for children ages
RequiredRequiredRequiredRequired
This drawing can be
scaled only when in an 18" x 24" format Minimum Area Required: Scale: Drawing Name: Date: This Unit includes play events and Drawn By: routes or travel specifically designed for special needs users. It is the opinion of the manufacturer that these play events and routes of travel conform to the accessibility requirements of the ADA (Americans with Disabilities Act) IMPORTANT: Soft resilient surfacing should be placed in the use zones of all equipment, as specified for each type of equipment, and at depths to meet the critical fall heights as specified by the U.S. consumer Product Safety Commission, ASTM standard F 1487 and Canadian Standard CAN/CSA-Z-614 C E R T I F I E D 150 PlayCore Drive SE Fort Payne, AL 35967 www.gametime.com 1 4 0 0 1 CERTIFIED City of Los Alamitos Sterns Park Los Alamitos, CA Great Western Recreation LC10/02/2023 109292-01 Option 2 5 - 12 - 178 5 17 5 9 6 4 3 SALES REP BRANDON SEITZ 805-910-5971 [email protected] This fitness equipment is recomended for children ages 13+
PALETTE COLOR SELECTIONS
Project: Approved by:______________________________________ Surfacing:
Hirsch & Associates Inc.
Attn: Naomi
2221 East Winston Rd. Suite A
Anaheim, CA 92806
Phone: 714-776-4340 Ext. 104
[email protected]
Ship to Zip 90720
Quantity Part # Description Unit Price Amount
1 RDU GameTime - Custom Inclusive Play StructureReference drawing #109292-01 Option 2$180,059.00 $180,059.00 1 91541 GameTime - 14' Hex Canopy $10,855.00 $10,855.00 1 80194 GameTime - Sunblox Hex Canopy $19,042.00 $19,042.00 2 6142 GameTime - Whirlwind Seat Tilted (F/S) $945.00 $1,890.00 1 5192 GT-Shade - Double Bay Swing Shade $12,090.00 $12,090.00 1 RDU GameTime - SwingsReference drawing #109292-01 Option 2$3,297.00 $3,297.00 1 13558I GameTime - Shoulder Rotator (In-Ground) $5,587.00 $5,587.00 1 13586I GameTime - Horizontal Chin Up In ground $2,034.00 $2,034.00 1 14901 GameTime - Assisted Step Trainer $4,406.00 $4,406.00 1 14911 GameTime - Thrive 250 $14,856.00 $14,856.00
1 15504 GameTime - Parallel Bar (Accessible) $1,997.00 $1,997.00 1 13271I GameTime - Chest Press - Ada (In-Ground Mount) $7,791.00 $7,791.00 Contract: OMNIA #2017001134 Sub Total $263,904.00
Discount ($54,881.87)
Freight $11,543.17
Tax $19,334.55
Total $239,899.85
GameTime C/O Great Western Recreation
P.O. Box 680121
Fort Payne, AL 35967
Office: 435-245-5055 Fax: 435-245-5057
www.gwpark.com
10/03/2023
Quote #
109292-01-03
City of Los Alamitos - Sterns Park Playground Option 2
Comments
Your Sales Rep is Brandon Seitz. Please reach out to Brandon at 805-910-5971 if you should have any questions regarding this quote.
Due to the volatility of freight costs, the freight pricing is subject to change at the time of order.
Pricing is subject to change. Request updated pricing when purchasing from quotes more than 30 days old.
Shipping to site:
3871 Farquhar Ave.
Los Alamitos, CA 90720
*Freight charges are based on listed zip code and are subject to change if shipping information changes. *Deposit may be required.
Customer is responsible for offloading.
Installation not included.
ONMIA #4001692
Remit Payment to:
GameTime
P.O. Box 680121
Fort Payne, AL 35968
Taxes:
All applicable taxes will be added at time of invoicing unless otherwise included or a tax-exempt certificate is provided.
If sales tax exempt, you must provide a copy of certificate to be considered exempt.
Prices:
FOB Factory.
Orders:
All orders shall be in writing by purchase order, contract, or similar document made out to PlayCore Wisconsin Inc., dba GameTime.
Standard GameTime equipment orders over $100,000 may require a deposit of 25% at the time of order and an additional 25% at or before order ships Standard orders with equipment, installation and surfacing are requested to be split billed.
Equipment, Taxes & Freight as noted above
Installation and Surfacing billed as completed and Due Upon Receipt.
Terms:
Cash With Order Discount (CWO): Orders for GameTime equipment paid in full at time of order via check, Electronic Funds Transfer (ACH or wire) are eligible for a three percent (3%) cash with order discount.
Payment via credit card: If you elect to pay by credit card, GameTime charges a 2.50% processing fee that is assessed on the amount of your payment. This fee is shown as a separate line item and included in the total amount charged to your credit card. You have the option to pay by check, ACH or Wire without any additional fees.
Credit terms are Net 30 days, subject to approval by the GameTime Credit Manager. A completed credit application must be submitted and approved prior to the order being received. Please allow at minimum 2 days for the credit review process. GameTime may also require:
Completed Project Information Sheet (if applicable)
Copies of Payment and Performance Bonds (if applicable) A 1.5% per month finance charge will be imposed on all past due invoices.
Retainage not accepted.
Orders under $5,000 require payment with order.
GameTime C/O Great Western Recreation
P.O. Box 680121
Fort Payne, AL 35967
Office: 435-245-5055 Fax: 435-245-5057
www.gwpark.com
10/03/2023
Quote #
109292-01-03
City of Los Alamitos - Sterns Park Playground Option 2
SUPPLY ONLY:
All items are quoted supply only.
Installation services are not included.
Customer is responsible for coordinating delivery, receipt, unloading, and inventory equipment.
Missing or damaged equipment must be reported within 60 days of delivery.
ACCEPTANCE OF QUOTATION:
Acceptance of this proposal indicates your agreement to the terms and conditions stated herein.
Purchase Amount: $239,899.85 Date: _______________________________ ________________________________________________________________ Signature
Please fill out this ORDER FORM, this is required to process the order.
GameTime C/O Great Western Recreation
P.O. Box 680121
Fort Payne, AL 35967
Office: 435-245-5055 Fax: 435-245-5057
www.gwpark.com
10/03/2023
Quote #
109292-01-03
City of Los Alamitos - Sterns Park Playground Option 2